Sample records for machine interface mmi

  1. Man-systems integration and the man-machine interface

    NASA Technical Reports Server (NTRS)

    Hale, Joseph P.

    1990-01-01

    Viewgraphs on man-systems integration and the man-machine interface are presented. Man-systems integration applies the systems' approach to the integration of the user and the machine to form an effective, symbiotic Man-Machine System (MMS). A MMS is a combination of one or more human beings and one or more physical components that are integrated through the common purpose of achieving some objective. The human operator interacts with the system through the Man-Machine Interface (MMI).

  2. ORACLE (Oversight of Resources and Capability for Logistics Effectiveness) and Requirements Forecasting. Volume 3. Predicting the Peacetime Spares Requirements.

    DTIC Science & Technology

    1988-05-01

    Shearing Machines WR/MMI DG 3446 Forging Machinery and Hammers WR/MMI DG 3447 Wire and Metal Ribbon Forming Machines WR/MMI DG 3448 Riveting Machines ...R/MN1I DG 3449 Miscellaneous Secondary Metal Forming & Cutting WR/MMI DG Machinery 3450 Machine Tools, Portable WR/MMI DG 3455 Cutting Tools for...Secondary Metalworking Machinery WR/MMI DG WR 3465 Production Jigs, Fixtures and Templates WR/MMI DG WR 3470 Machine Shop Sets, Kits, and Outfits WR/MMI DG

  3. Geolocating thermal binoculars based on a software defined camera core incorporating HOT MCT grown by MOVPE

    NASA Astrophysics Data System (ADS)

    Pillans, Luke; Harmer, Jack; Edwards, Tim; Richardson, Lee

    2016-05-01

    Geolocation is the process of calculating a target position based on bearing and range relative to the known location of the observer. A high performance thermal imager with integrated geolocation functions is a powerful long range targeting device. Firefly is a software defined camera core incorporating a system-on-a-chip processor running the AndroidTM operating system. The processor has a range of industry standard serial interfaces which were used to interface to peripheral devices including a laser rangefinder and a digital magnetic compass. The core has built in Global Positioning System (GPS) which provides the third variable required for geolocation. The graphical capability of Firefly allowed flexibility in the design of the man-machine interface (MMI), so the finished system can give access to extensive functionality without appearing cumbersome or over-complicated to the user. This paper covers both the hardware and software design of the system, including how the camera core influenced the selection of peripheral hardware, and the MMI design process which incorporated user feedback at various stages.

  4. Man-Machine Interface (MMI) Requirements Definition and Design Guidelines

    DTIC Science & Technology

    1981-02-01

    be provided to interrogate the user to resolve any input ambiguities resulting from hardware limitations; see Smith and Goodwin, 1971 . Reference...Smith, S. L. and Goodwin, N. C’. Alphabetic data v entry via the Touch-Tone pad: A comment. Human Factors, 1971 , 13(2), 189-190. 41 All~ 1.0 General (con...software designer. Reference: Miller, R. B. Response time in man-computer conversational transactions. In Proceedings of the AFIPS kall Joint Computer

  5. Upper limb functional electrical stimulation devices and their man-machine interfaces.

    PubMed

    Venugopalan, L; Taylor, P N; Cobb, J E; Swain, I D

    2015-01-01

    Functional Electrical Stimulation (FES) is a technique that uses electricity to activate the nerves of a muscle that is paralysed due to hemiplegia, multiple sclerosis, Parkinson's disease or spinal cord injury (SCI). FES has been widely used to restore upper limb functions in people with hemiplegia and C5-C7 tetraplegia and has improved their ability to perform their activities of daily living (ADL). At the time of writing, a detailed literature review of the existing upper limb FES devices and their man-machine interfaces (MMI) showed that only the NESS H200 was commercially available. However, the rigid arm splint doesn't fit everyone and prevents the use of a tenodesis grip. Hence, a robust and versatile upper limb FES device that can be used by a wider group of people is required.

  6. An Intelligent Man-Machine Interface—Multi-Robot Control Adapted for Task Engagement Based on Single-Trial Detectability of P300

    PubMed Central

    Kirchner, Elsa A.; Kim, Su K.; Tabie, Marc; Wöhrle, Hendrik; Maurus, Michael; Kirchner, Frank

    2016-01-01

    Advanced man-machine interfaces (MMIs) are being developed for teleoperating robots at remote and hardly accessible places. Such MMIs make use of a virtual environment and can therefore make the operator immerse him-/herself into the environment of the robot. In this paper, we present our developed MMI for multi-robot control. Our MMI can adapt to changes in task load and task engagement online. Applying our approach of embedded Brain Reading we improve user support and efficiency of interaction. The level of task engagement was inferred from the single-trial detectability of P300-related brain activity that was naturally evoked during interaction. With our approach no secondary task is needed to measure task load. It is based on research results on the single-stimulus paradigm, distribution of brain resources and its effect on the P300 event-related component. It further considers effects of the modulation caused by a delayed reaction time on the P300 component evoked by complex responses to task-relevant messages. We prove our concept using single-trial based machine learning analysis, analysis of averaged event-related potentials and behavioral analysis. As main results we show (1) a significant improvement of runtime needed to perform the interaction tasks compared to a setting in which all subjects could easily perform the tasks. We show that (2) the single-trial detectability of the event-related potential P300 can be used to measure the changes in task load and task engagement during complex interaction while also being sensitive to the level of experience of the operator and (3) can be used to adapt the MMI individually to the different needs of users without increasing total workload. Our online adaptation of the proposed MMI is based on a continuous supervision of the operator's cognitive resources by means of embedded Brain Reading. Operators with different qualifications or capabilities receive only as many tasks as they can perform to avoid mental overload as well as mental underload. PMID:27445742

  7. Manipulating attention via mindfulness induction improves P300-based brain-computer interface performance

    NASA Astrophysics Data System (ADS)

    Lakey, Chad E.; Berry, Daniel R.; Sellers, Eric W.

    2011-04-01

    In this study, we examined the effects of a short mindfulness meditation induction (MMI) on the performance of a P300-based brain-computer interface (BCI) task. We expected that MMI would harness present-moment attentional resources, resulting in two positive consequences for P300-based BCI use. Specifically, we believed that MMI would facilitate increases in task accuracy and promote the production of robust P300 amplitudes. Sixteen-channel electroencephalographic data were recorded from 18 subjects using a row/column speller task paradigm. Nine subjects participated in a 6 min MMI and an additional nine subjects served as a control group. Subjects were presented with a 6 × 6 matrix of alphanumeric characters on a computer monitor. Stimuli were flashed at a stimulus onset asynchrony (SOA) of 125 ms. Calibration data were collected on 21 items without providing feedback. These data were used to derive a stepwise linear discriminate analysis classifier that was applied to an additional 14 items to evaluate accuracy. Offline performance analyses revealed that MMI subjects were significantly more accurate than control subjects. Likewise, MMI subjects produced significantly larger P300 amplitudes than control subjects at Cz and PO7. The discussion focuses on the potential attentional benefits of MMI for P300-based BCI performance.

  8. Human factor engineering based design and modernization of control rooms with new I and C systems

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Larraz, J.; Rejas, L.; Ortega, F.

    2012-07-01

    Instrumentation and Control (I and C) systems of the latest nuclear power plants are based on the use of digital technology, distributed control systems and the integration of information in data networks (Distributed Control and Instrumentation Systems). This has a repercussion on Control Rooms (CRs), where the operations and monitoring interfaces correspond to these systems. These technologies are also used in modernizing I and C systems in currently operative nuclear power plants. The new interfaces provide additional capabilities for operation and supervision, as well as a high degree of flexibility, versatility and reliability. An example of this is the implementationmore » of solutions such as compact stations, high level supervision screens, overview displays, computerized procedures, new operational support systems or intelligent alarms processing systems in the modernized Man-Machine Interface (MMI). These changes in the MMI are accompanied by newly added Software (SW) controls and new solutions in automation. Tecnatom has been leading various projects in this area for several years, both in Asian countries and in the United States, using in all cases international standards from which Tecnatom own methodologies have been developed and optimized. The experience acquired in applying this methodology to the design of new control rooms is to a large extent applicable also to the modernization of current control rooms. An adequate design of the interface between the operator and the systems will facilitate safe operation, contribute to the prompt identification of problems and help in the distribution of tasks and communications between the different members of the operating shift. Based on Tecnatom experience in the field, this article presents the methodological approach used as well as the most relevant aspects of this kind of project. (authors)« less

  9. Mobility Systems For Robotic Vehicles

    NASA Astrophysics Data System (ADS)

    Chun, Wendell

    1987-02-01

    The majority of existing robotic systems can be decomposed into five distinct subsystems: locomotion, control/man-machine interface (MMI), sensors, power source, and manipulator. When designing robotic vehicles, there are two main requirements: first, to design for the environment and second, for the task. The environment can be correlated with known missions. This can be seen by analyzing existing mobile robots. Ground mobile systems are generally wheeled, tracked, or legged. More recently, underwater vehicles have gained greater attention. For example, Jason Jr. made history by surveying the sunken luxury liner, the Titanic. The next big surge of robotic vehicles will be in space. This will evolve as a result of NASA's commitment to the Space Station. The foreseeable robots will interface with current systems as well as standalone, free-flying systems. A space robotic vehicle is similar to its underwater counterpart with very few differences. Their commonality includes missions and degrees-of-freedom. The issues of stability and communication are inherent in both systems and environment.

  10. Visually Coupled Systems (VCS): The Virtual Panoramic Display (VPD) System

    NASA Technical Reports Server (NTRS)

    Kocian, Dean F.

    1992-01-01

    The development and impact is described of new visually coupled system (VCS) equipment designed to support engineering and human factors research in the military aircraft cockpit environment. VCS represents an advanced man-machine interface (MMI). Its potential to improve aircrew situational awareness seems enormous, but its superiority over the conventional cockpit MMI has not been established in a conclusive and rigorous fashion. What has been missing is a 'systems' approach to technology advancement that is comprehensive enough to produce conclusive results concerning the operational viability of the VCS concept and verify any risk factors that might be involved with its general use in the cockpit. The advanced VCS configuration described here, was ruggedized for use in military aircraft environments and was dubbed the Virtual Panoramic Display (VPD). It was designed to answer the VCS portion of the systems problem, and is implemented as a modular system whose performance can be tailored to specific application requirements. The overall system concept and the design of the two most important electronic subsystems that support the helmet mounted parts, a new militarized version of the magnetic helmet mounted sight and correspondingly similar helmet display electronics, are discussed in detail. Significant emphasis is given to illustrating how particular design features in the hardware improve overall system performance and support research activities.

  11. Microgrid and Inverter Control and Simulator Software

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    2012-09-13

    A collection of software that can simulate the operation of an inverter on a microgrid or control a real inverter. In addition, it can simulate the control of multiple nodes on a microgrid." Application: Simulation of inverters and microgrids; control of inverters on microgrids." The MMI submodule is designed to control custom inverter hardware, and to simulate that hardware. The INVERTER submodule is only the simulator code, and is of an earlier generation than the simulator in MMI. The MICROGRID submodule is an agent-based simulator of multiple nodes on a microgrid which presents a web interface. The WIND submodule producesmore » movies of wind data with a web interface.« less

  12. The multiple mini-interview for emergency medicine resident selection.

    PubMed

    Hopson, Laura R; Burkhardt, John C; Stansfield, R Brent; Vohra, Taher; Turner-Lawrence, Danielle; Losman, Eve D

    2014-04-01

    The Multiple Mini-Interview (MMI) uses multiple, short-structured contacts to evaluate communication and professionalism. It predicts medical school success better than the traditional interview and application. Its acceptability and utility in emergency medicine (EM) residency selection are unknown. We theorized that participants would judge the MMI equal to a traditional unstructured interview and it would provide new information for candidate assessment. Seventy-one interns from 3 programs in the first month of training completed an eight-station MMI focused on EM topics. Pre- and post-surveys assessed reactions. MMI scores were compared with application data. EM grades correlated with MMI performance (F[1, 66] = 4.18; p < 0.05) with honors students having higher scores. Higher third-year clerkship grades were associated with higher MMI performance, although this was not statistically significant. MMI performance did not correlate with match desirability and did not predict most other components of an application. There was a correlation between lower MMI scores and lower global ranking on the Standardized Letter of Recommendation. Participants preferred a traditional interview (mean difference = 1.36; p < 0.01). A mixed format (traditional interview and MMI) was preferred over a MMI alone (mean difference = 1.1; p < 0.01). MMI performance did not significantly correlate with preference for the MMI. Although the MMI alone was viewed less favorably than a traditional interview, participants were receptive to a mixed-methods interview. The MMI does correlate with performance on the EM clerkship and therefore can measure important abilities for EM success. Future work will determine whether MMI performance predicts residency performance. Copyright © 2014 Elsevier Inc. All rights reserved.

  13. Revisiting the contemporary sea-level budget on global and regional scales

    PubMed Central

    Brunnabend, Sandra-Esther; Kusche, Jürgen; Schröter, Jens; Dahle, Christoph

    2016-01-01

    Dividing the sea-level budget into contributions from ice sheets and glaciers, the water cycle, steric expansion, and crustal movement is challenging, especially on regional scales. Here, Gravity Recovery And Climate Experiment (GRACE) gravity observations and sea-level anomalies from altimetry are used in a joint inversion, ensuring a consistent decomposition of the global and regional sea-level rise budget. Over the years 2002–2014, we find a global mean steric trend of 1.38 ± 0.16 mm/y, compared with a total trend of 2.74 ± 0.58 mm/y. This is significantly larger than steric trends derived from in situ temperature/salinity profiles and models which range from 0.66 ± 0.2 to 0.94 ± 0.1 mm/y. Mass contributions from ice sheets and glaciers (1.37 ± 0.09 mm/y, accelerating with 0.03 ± 0.02 mm/y2) are offset by a negative hydrological component (−0.29 ± 0.26 mm/y). The combined mass rate (1.08 ± 0.3 mm/y) is smaller than previous GRACE estimates (up to 2 mm/y), but it is consistent with the sum of individual contributions (ice sheets, glaciers, and hydrology) found in literature. The altimetric sea-level budget is closed by coestimating a remaining component of 0.22 ± 0.26 mm/y. Well above average sea-level rise is found regionally near the Philippines (14.7 ± 4.39 mm/y) and Indonesia (8.3 ± 4.7 mm/y) which is dominated by steric components (11.2 ± 3.58 mm/y and 6.4 ± 3.18 mm/y, respectively). In contrast, in the central and Eastern part of the Pacific, negative steric trends (down to −2.8 ± 1.53 mm/y) are detected. Significant regional components are found, up to 5.3 ± 2.6 mm/y in the northwest Atlantic, which are likely due to ocean bottom pressure variations. PMID:26811469

  14. Revisiting the contemporary sea-level budget on global and regional scales.

    PubMed

    Rietbroek, Roelof; Brunnabend, Sandra-Esther; Kusche, Jürgen; Schröter, Jens; Dahle, Christoph

    2016-02-09

    Dividing the sea-level budget into contributions from ice sheets and glaciers, the water cycle, steric expansion, and crustal movement is challenging, especially on regional scales. Here, Gravity Recovery And Climate Experiment (GRACE) gravity observations and sea-level anomalies from altimetry are used in a joint inversion, ensuring a consistent decomposition of the global and regional sea-level rise budget. Over the years 2002-2014, we find a global mean steric trend of 1.38 ± 0.16 mm/y, compared with a total trend of 2.74 ± 0.58 mm/y. This is significantly larger than steric trends derived from in situ temperature/salinity profiles and models which range from 0.66 ± 0.2 to 0.94 ± 0.1 mm/y. Mass contributions from ice sheets and glaciers (1.37 ± 0.09 mm/y, accelerating with 0.03 ± 0.02 mm/y(2)) are offset by a negative hydrological component (-0.29 ± 0.26 mm/y). The combined mass rate (1.08 ± 0.3 mm/y) is smaller than previous GRACE estimates (up to 2 mm/y), but it is consistent with the sum of individual contributions (ice sheets, glaciers, and hydrology) found in literature. The altimetric sea-level budget is closed by coestimating a remaining component of 0.22 ± 0.26 mm/y. Well above average sea-level rise is found regionally near the Philippines (14.7 ± 4.39 mm/y) and Indonesia (8.3 ± 4.7 mm/y) which is dominated by steric components (11.2 ± 3.58 mm/y and 6.4 ± 3.18 mm/y, respectively). In contrast, in the central and Eastern part of the Pacific, negative steric trends (down to -2.8 ± 1.53 mm/y) are detected. Significant regional components are found, up to 5.3 ± 2.6 mm/y in the northwest Atlantic, which are likely due to ocean bottom pressure variations.

  15. Analysis of the rectangular resonator with butterfly MMI coupler using SOI

    NASA Astrophysics Data System (ADS)

    Kim, Sun-Ho; Park, Jun-Hee; Kim, Eudum; Jeon, Su-Jin; Kim, Ji-Hoon; Choi, Young-Wan

    2018-02-01

    We propose a rectangular resonator sensor structure with butterfly MMI coupler using SOI. It consists of the rectangular resonator, total internal reflection (TIR) mirror, and the butterfly MMI coupler. The rectangular resonator is expected to be used as bio and chemical sensors because of the advantages of using MMI coupler and the absence of bending loss unlike ring resonators. The butterfly MMI coupler can miniaturize the device compared to conventional MMI by using a linear butterfly shape instead of a square in the MMI part. The width, height, and slab height of the rib type waveguide are designed to be 1.5 μm, 1.5 μm, and 0.9 μm, respectively. This structure is designed as a single mode. When designing a TIR mirror, we considered the Goos-Hänchen shift and critical angle. We designed 3:1 MMI coupler because rectangular resonator has no bending loss. The width of MMI is designed to be 4.5 μm and we optimize the length of the butterfly MMI coupler using finite-difference time-domain (FDTD) method for higher Q-factor. It has the equal performance with conventional MMI even though the length is reduced by 1/3. As a result of the simulation, Qfactor of rectangular resonator can be obtained as 7381.

  16. The MMI Semantic Framework: Rosetta Stones for Earth Sciences

    NASA Astrophysics Data System (ADS)

    Rueda, C.; Bermudez, L. E.; Graybeal, J.; Alexander, P.

    2009-12-01

    Semantic interoperability—the exchange of meaning among computer systems—is needed to successfully share data in Ocean Science and across all Earth sciences. The best approach toward semantic interoperability requires a designed framework, and operationally tested tools and infrastructure within that framework. Currently available technologies make a scientific semantic framework feasible, but its development requires sustainable architectural vision and development processes. This presentation outlines the MMI Semantic Framework, including recent progress on it and its client applications. The MMI Semantic Framework consists of tools, infrastructure, and operational and community procedures and best practices, to meet short-term and long-term semantic interoperability goals. The design and prioritization of the semantic framework capabilities are based on real-world scenarios in Earth observation systems. We describe some key uses cases, as well as the associated requirements for building the overall infrastructure, which is realized through the MMI Ontology Registry and Repository. This system includes support for community creation and sharing of semantic content, ontology registration, version management, and seamless integration of user-friendly tools and application programming interfaces. The presentation describes the architectural components for semantic mediation, registry and repository for vocabularies, ontology, and term mappings. We show how the technologies and approaches in the framework can address community needs for managing and exchanging semantic information. We will demonstrate how different types of users and client applications exploit the tools and services for data aggregation, visualization, archiving, and integration. Specific examples from OOSTethys (http://www.oostethys.org) and the Ocean Observatories Initiative Cyberinfrastructure (http://www.oceanobservatories.org) will be cited. Finally, we show how semantic augmentation of web services standards could be performed using framework tools.

  17. Potential teratogenicity of methimazole: exposure of zebrafish embryos to methimazole causes similar developmental anomalies to human methimazole embryopathy.

    PubMed

    Komoike, Yuta; Matsuoka, Masato; Kosaki, Kenjiro

    2013-06-01

    While methimazole (MMI) is widely used in the therapy for hyperthyroidism, several groups have reported that maternal exposure to MMI results in a variety of congenital anomalies, including choanal and esophageal atresia, iridic and retinal coloboma, and delayed neurodevelopment. Thus, adverse effects of maternal exposure to MMI on fetal development have long been suggested; however, direct evidence for the teratogenicity of MMI has not been presented. Therefore, we studied the effects of MMI on early development by using zebrafish as a model organism. The fertilized eggs of zebrafish were collected immediately after spawning and grown in egg culture water containing MMI at various concentrations. External observation of the embryos revealed that exposure to high concentrations of MMI resulted in loss of pigmentation, hypoplastic hindbrain, turbid tissue in the forebrain, swelling of the notochord, and curly trunk. Furthermore, these effects occurred in a dose-dependent manner. Precise observation of the serial cross-sections of MMI-exposed embryos elucidated delayed development and hypoplasia of the whole brain and spinal cord, narrowing of the pharynx and esophagus, severe disruption of the retina, and aberrant structure of the notochord. These neuronal, pharyngeal, esophageal, and retinal anomalous morphologies have a direct analogy to the congenital anomalies observed in children exposed to MMI in utero. Here, we show the teratogenic effects of MMI on the development of zebrafish and provide the first experimental evidence for the connection between exposure to MMI and human MMI embryopathy. © 2013 Wiley Periodicals, Inc.

  18. Mmi1, the Yeast Homologue of Mammalian TCTP, Associates with Stress Granules in Heat-Shocked Cells and Modulates Proteasome Activity

    PubMed Central

    Grousl, Tomas; Stradalova, Vendula; Heeren, Gino; Richter, Klaus; Breitenbach-Koller, Lore; Malinsky, Jan; Hasek, Jiri; Breitenbach, Michael

    2013-01-01

    As we have shown previously, yeast Mmi1 protein translocates from the cytoplasm to the outer surface of mitochondria when vegetatively growing yeast cells are exposed to oxidative stress. Here we analyzed the effect of heat stress on Mmi1 distribution. We performed domain analyses and found that binding of Mmi1 to mitochondria is mediated by its central alpha-helical domain (V-domain) under all conditions tested. In contrast, the isolated N-terminal flexible loop domain of the protein always displays nuclear localization. Using immunoelectron microscopy we confirmed re-location of Mmi1 to the nucleus and showed association of Mmi1 with intact and heat shock-altered mitochondria. We also show here that mmi1Δ mutant strains are resistant to robust heat shock with respect to clonogenicity of the cells. To elucidate this phenotype we found that the cytosolic Mmi1 holoprotein re-localized to the nucleus even in cells heat-shocked at 40°C. Upon robust heat shock at 46°C, Mmi1 partly co-localized with the proteasome marker Rpn1 in the nuclear region as well as with the cytoplasmic stress granules defined by Rpg1 (eIF3a). We co-localized Mmi1 also with Bre5, Ubp3 and Cdc48 which are involved in the protein de-ubiquitination machinery, protecting protein substrates from proteasomal degradation. A comparison of proteolytic activities of wild type and mmi1Δ cells revealed that Mmi1 appears to be an inhibitor of the proteasome. We conclude that one of the physiological functions of the multifunctional protein module, Mmi1, is likely in regulating degradation and/or protection of proteins thereby indirectly regulating the pathways leading to cell death in stressed cells. PMID:24204967

  19. Prevention of relapse of Graves' disease by treatment with an intrathyroid injection of dexamethasone.

    PubMed

    Mao, Xiao-Ming; Li, Hui-Qin; Li, Qian; Li, Dong-Mei; Xie, Xiao-Jing; Yin, Guo-Ping; Zhang, Peng; Xu, Xiang-Hong; Wu, Jin-Dan; Chen, Song-Wang; Wang, Shu-Kui

    2009-12-01

    Antithyroid drugs are widely used in the treatment of Graves' disease (GD), but the relapse rate is very high after therapy withdrawal. We evaluated the reduction effects of intrathyroid injection of dexamethasone (IID) on the relapse rate of hyperthyroidism in patients with newly diagnosed GD. A total of 191 patients with GD completed the study. After 6 months of treatment with methimazole (MMI), the patients were randomly assigned to receive either MMI (96 patients) alone or MMI combined with IID (MMI+IID; 95 patients) treatment for 3 months, followed by continuing a dose of MMI that would maintain euthyroidism for the next 9 months in all of the patients. After withdrawal of the medical therapy, patients were followed for 24 months, and the relapse rate of hyperthyroidism was evaluated. No statistical difference was observed in the levels of serum FT(4), TSH, or TSH receptor antibodies (TR-Ab), the thyroid volume, or the TR-Ab positive rate between the two groups at month 6. After the next 3 months of treatment with MMI+IID or MMI alone, the levels of TSH increased significantly, and the levels of serum TR-Ab, the TR-Ab positive rate, and thyroid volume decreased significantly in the MMI+IID group compared with the MMI group. Seven patients (7.4%) experienced a relapse of overt hyperthyroidism in the MMI+IID group and 49 patients (51%) in MMI group during the 2-yr follow-up period (P < 0.001). MMI+IID treatment is helpful to prevent relapse of hyperthyroidism in GD after medical therapy withdrawal.

  20. Anti-invasive and antiangiogenic effects of MMI-166 on malignant glioma cells

    PubMed Central

    2010-01-01

    Background The constitutive overexpression of matrix metalloproteinases (MMPs) is frequently observed in malignant tumours. In particular, MMP-2 and MMP-9 have been reported to be closely associated with invasion and angiogenesis in malignant gliomas. Our study aimed to evaluate the antitumour effects of MMI-166 (Nalpha-[4-(2-Phenyl-2H- tetrazole-5-yl) phenyl sulfonyl]-D-tryptophan), a third generation MMP inhibitor, on three human glioma cell lines (T98G, U87MG, and ONS12) in vitro and in vivo. Methods The effects of MMI-166 on the gelatinolytic activity was analysed by gelatine zymography. The anti-invasive effect of MMI-166 was analysed by an in vitro invasion assay. An in vitro angiogenesis assay was also performed. In vitro growth inhibition of glioma cells by MMI-166 was determined by the MTT assay. The effect of MMI-166 on an orthotropic implantation model using athymic mice was also evaluated. Results Gelatine zymography revealed that MMP-2 and MMP-9 activities were suppressed by MMI-166. The invasion of glioma cells was suppressed by MMI-166. The angiogenesis assay showed that MMI-166 had a suppressive effect on glioma cell-induced angiogenesis. However, MMI-166 did not suppress glioma cell proliferation in the MTT assay. In vivo, MMI-166 suppressed tumour growth in athymic mice implanted orthotropically with T98G cells and showed an inhibitory effect on tumour-induced angiogenesis and tumour growth. This is the first report of the effect of a third generation MMP inhibitor on malignant glioma cells. Conclusions These results suggest that MMI-166 may have potentially suppressive effects on the invasion and angiogenesis of malignant gliomas. PMID:20587068

  1. Unsupervised Domain Adaptation with Multiple Acoustic Models

    DTIC Science & Technology

    2010-12-01

    Discriminative MAP Adaptation Standard ML-MAP has been extended to incorporate discrim- inative training criteria such as MMI and MPE [10]. Dis- criminative MAP...smoothing variable I . For example, the MMI - MAP mean is given by ( mmi -map) jm = fnumjm (O) den jm(O)g+Djm̂jm + I (ml-map) jm f numjm den... MMI training, and Djm is the Gaussian-dependent parameter for the extended Baum-Welch (EBW) algorithm. MMI -MAP has been successfully applied in

  2. Augmented growth inhibition of B16-BL6 melanoma by combined treatment with a selective matrix metalloproteinase inhibitor, MMI-166, and cytotoxic agents.

    PubMed

    Hojo, Kanji; Maki, Hideo; Sawada, Takuko Yamada; Maekawa, Ryuji; Yoshioka, Takayuki

    2002-01-01

    MMI-166 is a selective matrix metalloproteinase (MMP) inhibitor. The purpose of this study was to evaluate the antitumor efficacy of the combined treatment of MMI-166 with paclitaxel or carboplatin. Mice bearing B16-BL6 melanoma were treated p.o. with MMI-166 from 1 day after tumor inoculation. The mice were administered i.v. with either paclitaxel or carboplatin at the maximum tolerated dose (MTD). MMI-166 monotherapy inhibited in vivo growth of the B16-BL6 tumor to an extent similar to that of paclitaxel or carboplatin monotherapy. When MMI-166 was combined with paclitaxel or carboplatin, the antitumor efficacy was significantly (p < 0.01) augmented in comparison with either MMI-166 or each cytotoxic agent alone. The hematotoxicity study demonstrated that daily treatment with MMI-166 did not affect the blood cell number in the mice and more importantly the combination of MMI-166 with paclitaxel did not augment the hematotoxicity caused by paclitaxel. An in vitro cytotoxicity study showed that MMI-166 itself has neither direct cytotoxicity against B16-BL6 tumor cells nor does it augment the cytotoxicity of paclitaxel or carboplatin. These results indicate that augmented antitumor activity of the combination treatment was not simply due to the augmentation of direct cytotoxic activity, but was rather an additive effect of the antitumor activities of different mechanisms. They suggest the effectiveness of a combination therapy of MMI-166 with paclitaxel or carboplatin in clinical therapy.

  3. What does the multiple mini interview have to offer over the panel interview?

    PubMed

    Pau, Allan; Chen, Yu Sui; Lee, Verna Kar Mun; Sow, Chew Fei; De Alwis, Ranjit

    2016-01-01

    This paper compares the panel interview (PI) performance with the multiple mini interview (MMI) performance and indication of behavioural concerns of a sample of medical school applicants. The acceptability of the MMI was also assessed. All applicants shortlisted for a PI were invited to an MMI. Applicants attended a 30-min PI with two faculty interviewers followed by an MMI consisting of ten 8-min stations. Applicants were assessed on their performance at each MMI station by one faculty. The interviewer also indicated if they perceived the applicant to be a concern. Finally, applicants completed an acceptability questionnaire. From the analysis of 133 (75.1%) completed MMI scoresheets, the MMI scores correlated statistically significantly with the PI scores (r=0.438, p=0.001). Both were not statistically associated with sex, age, race, or pre-university academic ability to any significance. Applicants assessed as a concern at two or more stations performed statistically significantly less well at the MMI when compared with those who were assessed as a concern at one station or none at all. However, there was no association with PI performance. Acceptability scores were generally high, and comparison of mean scores for each of the acceptability questionnaire items did not show statistically significant differences between sex and race categories. Although PI and MMI performances are correlated, the MMI may have the added advantage of more objectively generating multiple impressions of the applicant's interpersonal skill, thoughtfulness, and general demeanour. Results of the present study indicated that the MMI is acceptable in a multicultural context.

  4. What does the multiple mini interview have to offer over the panel interview?

    PubMed Central

    Pau, Allan; Chen, Yu Sui; Lee, Verna Kar Mun; Sow, Chew Fei; Alwis, Ranjit De

    2016-01-01

    Introduction This paper compares the panel interview (PI) performance with the multiple mini interview (MMI) performance and indication of behavioural concerns of a sample of medical school applicants. The acceptability of the MMI was also assessed. Materials and methods All applicants shortlisted for a PI were invited to an MMI. Applicants attended a 30-min PI with two faculty interviewers followed by an MMI consisting of ten 8-min stations. Applicants were assessed on their performance at each MMI station by one faculty. The interviewer also indicated if they perceived the applicant to be a concern. Finally, applicants completed an acceptability questionnaire. Results From the analysis of 133 (75.1%) completed MMI scoresheets, the MMI scores correlated statistically significantly with the PI scores (r=0.438, p=0.001). Both were not statistically associated with sex, age, race, or pre-university academic ability to any significance. Applicants assessed as a concern at two or more stations performed statistically significantly less well at the MMI when compared with those who were assessed as a concern at one station or none at all. However, there was no association with PI performance. Acceptability scores were generally high, and comparison of mean scores for each of the acceptability questionnaire items did not show statistically significant differences between sex and race categories. Conclusions Although PI and MMI performances are correlated, the MMI may have the added advantage of more objectively generating multiple impressions of the applicant's interpersonal skill, thoughtfulness, and general demeanour. Results of the present study indicated that the MMI is acceptable in a multicultural context. PMID:26873337

  5. What does the multiple mini interview have to offer over the panel interview?

    PubMed

    Pau, Allan; Chen, Yu Sui; Lee, Verna Kar Mun; Sow, Chew Fei; Alwis, Ranjit De

    2016-01-01

    Introduction This paper compares the panel interview (PI) performance with the multiple mini interview (MMI) performance and indication of behavioural concerns of a sample of medical school applicants. The acceptability of the MMI was also assessed. Materials and methods All applicants shortlisted for a PI were invited to an MMI. Applicants attended a 30-min PI with two faculty interviewers followed by an MMI consisting of ten 8-min stations. Applicants were assessed on their performance at each MMI station by one faculty. The interviewer also indicated if they perceived the applicant to be a concern. Finally, applicants completed an acceptability questionnaire. Results From the analysis of 133 (75.1%) completed MMI scoresheets, the MMI scores correlated statistically significantly with the PI scores (r=0.438, p=0.001). Both were not statistically associated with sex, age, race, or pre-university academic ability to any significance. Applicants assessed as a concern at two or more stations performed statistically significantly less well at the MMI when compared with those who were assessed as a concern at one station or none at all. However, there was no association with PI performance. Acceptability scores were generally high, and comparison of mean scores for each of the acceptability questionnaire items did not show statistically significant differences between sex and race categories. Conclusions Although PI and MMI performances are correlated, the MMI may have the added advantage of more objectively generating multiple impressions of the applicant's interpersonal skill, thoughtfulness, and general demeanour. Results of the present study indicated that the MMI is acceptable in a multicultural context.

  6. Design and fabrication of multimode interference couplers based on digital micro-mirror system

    NASA Astrophysics Data System (ADS)

    Wu, Sumei; He, Xingdao; Shen, Chenbo

    2008-03-01

    Multimode interference (MMI) couplers, based on the self-imaging effect (SIE), are accepted popularly in integrated optics. According to the importance of MMI devices, in this paper, we present a novel method to design and fabricate MMI couplers. A technology of maskless lithography to make MMI couplers based on a smart digital micro-mirror device (DMD) system is proposed. A 1×4 MMI device is designed as an example, which shows the present method is efficient and cost-effective.

  7. Perceptions and Cost-Analysis of a Multiple Mini-Interview in a Pharmacy School Admissions Process.

    PubMed

    Corelli, Robin L; Muchnik, Michael A; Beechinor, Ryan J; Fong, Gary; Vogt, Eleanor M; Cocohoba, Jennifer M; Tsourounis, Candy; Hudmon, Karen Suchanek

    2015-11-25

    To improve the quality of admissions interviews for a doctor of pharmacy program, using a multiple mini-interview (MMI) in place of the standard interview. Stakeholders completed an anonymous web-based survey. This study characterized perceptions of the MMI format across 3 major stakeholders (candidates, interviewers, admissions committee members) and included comparative cost estimates.Costs were estimated using human and facility resources from the 2012 cycle (standard format) and the 2013 cycle (MMI format). Most candidates (65%), interviewers (86%), and admissions committee members (79%) perceived the MMI format as effective for evaluating applicants, and most (59% of candidates, 84% of interviewers, 77% of committee members) agreed that the MMI format should be continued. Cost per candidate interviewed was $136.34 (standard interview) vs $75.30 (MMI). Perceptions of the MMI process were favorable across stakeholder groups, and this format was less costly per candidate interviewed.

  8. Modified Mercalli Intensities (MMI) for some earthquakes in eastern North America (ENA) and empirical MMI site corrections for towns in ENA

    USGS Publications Warehouse

    Bakun, W.H.; Johnston, A.C.; Hopper, M.G.

    2002-01-01

    Modified Mercalli Intensity (MMI) assignments for earthquakes in eastern North America (ENA) were used by Bakun et al. (submitted) to develop a model for eastern North America for estimating the location and moment magnitude M of earthquakes from MMI observations. MMI assignments for most of the earthquakes considered by Bakun et al. (submitted) are published. MMI assignments for 6 other earthquakes used by Bakun et al. (submitted) are listed in this report: November 18, 1755 near Cape Ann, Massachusetts; January 5, 1843 near Marked Tree, Arkansas; October 31, 1895 in southern Illinois; November 18, 1929 on the Grand Banks, Newfoundland; September 26, 1990 in southeast Missouri; and May 4, 1991 near Risco, Missouri. MMI empirical site corrections developed and used by Bakun et al. (submitted) are also listed in this report.

  9. Development and Assessment of the Multiple Mini-Interview in a School of Pharmacy Admissions Model

    PubMed Central

    McLaughlin, Jacqueline E.; Singer, David; Lewis, Margaret; Dinkins, Melissa M.

    2015-01-01

    Objective. To describe the development, implementation, and evaluation of the multiple mini-interview (MMI) within a doctor of pharmacy (PharmD) admissions model. Methods. Demographic data and academic indicators were collected for all candidates who participated in Candidates’ Day (n=253), along with the score for each MMI station criteria (7 stations). A survey was administered to all candidates who completed the MMI, and another survey was administered to all interviewers to examine perceptions of the MMI. Results. Analyses suggest that MMI stations assessed different attributes as designed, with Cronbach alpha for each station ranging from 0.90 to 0.95. All correlations between MMI station scores and academic indicators were negligible. No significant differences in average station scores were found based on age, gender, or race. Conclusion. This study provides additional support for the use of the MMI as an admissions tool in pharmacy education. PMID:26089562

  10. Maternal transfer of methimazole and effects on thyroid hormone availability in embryonic tissues.

    PubMed

    Van Herck, Stijn L J; Geysens, Stijn; Bald, Edward; Chwatko, Grazyna; Delezie, Evelyne; Dianati, Elham; Ahmed, R G; Darras, Veerle M

    2013-07-01

    Methimazole (MMI) is an anti-thyroid drug used in the treatment of chronic hyperthyroidism. There is, however, some debate about its use during pregnancy as MMI is known to cross the mammalian placenta and reach the developing foetus. A similar problem occurs in birds, where MMI is deposited in the egg and taken up by the developing embryo. To investigate whether maternally derived MMI can have detrimental effects on embryonic development, we treated laying hens with MMI (0.03% in drinking water) and measured total and reduced MMI contents in the tissues of hens and embryos at different stages of development. In hens, MMI was selectively increased in the thyroid gland, while its levels in the liver and especially brain remained relatively low. Long-term MMI treatment induced a pronounced goitre with a decrease in thyroxine (T₄) content but an increase in thyroidal 3,5,3'-triiodothyronine (T₃) content. This resulted in normal T₃ levels in tissues except in the brain. In chicken embryos, MMI levels were similar in the liver and brain. They gradually decreased during development but always remained above those in the corresponding maternal tissues. Contrary to the situation in hens, T₄ availability was only moderately affected in embryos. Peripheral T₃ levels were reduced in 14-day-old embryos but normal in 18-day-old embryos, while brain T₃ content was decreased at all embryonic stages tested. We conclude that all embryonic tissues are exposed to relatively high doses of MMI and its oxidised metabolites. The effect of maternal MMI treatment on embryonic thyroid hormone availability is most pronounced for brain T₃ content, which is reduced throughout the embryonic development period.

  11. White matter damage and glymphatic dysfunction in a model of vascular dementia in rats with no prior vascular pathologies

    PubMed Central

    Venkat, Poornima; Chopp, Michael; Zacharek, Alex; Cui, Chengcheng; Zhang, Li; Li, Qingjiang; Lu, Mei; Zhang, Talan; Liu, Amy; Chen, Jieli

    2016-01-01

    We investigated cognitive function, axonal/white matter (WM) changes and glymphatic function of vascular dementia (VaD) using a multiple microinfarction (MMI) model in retired breeder (RB) rats. The MMI model induces significant (p<0.05) cognitive decline that worsens with age starting at 2 weeks, which persists until at least 6 weeks after MMI. RB rats subjected to MMI exhibit significant axonal/WM damage identified by decreased myelin thickness, oligodendrocyte progenitor cell numbers, axon density, synaptic protein expression in the cortex and striatum, cortical neuronal branching, and dendritic spine density in the cortex and hippocampus compared with age matched controls. MMI evokes significant dilation of perivascular spaces as well as water channel dysfunction indicated by decreased Aquaporin-4 (AQP-4) expression around blood vessels. MMI induced glymphatic dysfunction with delayed cerebrospinal fluid (CSF) penetration into the brain parenchyma via paravascular pathways as well as delayed waste clearance from the brain. The MMI model in RB rats decreases AQP-4 and induces glymphatic dysfunction which may play an important role in MMI induced axonal/WM damage and cognitive deficits. PMID:27940353

  12. White matter damage and glymphatic dysfunction in a model of vascular dementia in rats with no prior vascular pathologies.

    PubMed

    Venkat, Poornima; Chopp, Michael; Zacharek, Alex; Cui, Chengcheng; Zhang, Li; Li, Qingjiang; Lu, Mei; Zhang, Talan; Liu, Amy; Chen, Jieli

    2017-02-01

    We investigated cognitive function, axonal/white matter (WM) changes and glymphatic function of vascular dementia using a multiple microinfarction (MMI) model in retired breeder (RB) rats. The MMI model induces significant (p < 0.05) cognitive decline that worsens with age starting at 2 weeks, which persists until at least 6 weeks after MMI. RB rats subjected to MMI exhibit significant axonal/WM damage identified by decreased myelin thickness, oligodendrocyte progenitor cell numbers, axon density, synaptic protein expression in the cortex and striatum, cortical neuronal branching, and dendritic spine density in the cortex and hippocampus compared with age-matched controls. MMI evokes significant dilation of perivascular spaces as well as water channel dysfunction indicated by decreased Aquaporin-4 expression around blood vessels. MMI-induced glymphatic dysfunction with delayed cerebrospinal fluid penetration into the brain parenchyma via paravascular pathways as well as delayed waste clearance from the brain. The MMI model in RB rats decreases Aquaporin-4 and induces glymphatic dysfunction which may play an important role in MMI-induced axonal/WM damage and cognitive deficits. Copyright © 2016 Elsevier Inc. All rights reserved.

  13. Evaluating the MMI diagnostic on OMEGA direct-drive shots

    NASA Astrophysics Data System (ADS)

    Baumgaertel, J. A.; Bradley, P. A.; Cobble, J. A.; Fincke, J.; Hakel, P.; Hsu, S. C.; Kanzleiter, R.; Krasheninnikova, N. S.; Murphy, T. J.; Schmitt, M. J.; Shah, R.; Tregillis, I.; Obrey, K.; Mancini, R. C.; Joshi, T.; Johns, H.; Mayes, D.

    2013-10-01

    The Defect-Induced Mix Experiment (DIME) project utilized Multiple Monochromatic Imagers (MMI) on symmetric and polar direct-drive shots conducted on the OMEGA laser. The MMI provides spatially and spectrally resolved data of capsule implosions and resultant dopant emissions. The capsules had radii of 430 μm, with CH shells that included an inner layer doped with 1-2 atom % Ti, and a gas fill of 5 atm deuterium. Simulations of the target implosion by codes HYDRA and RAGE are post-processed with self-emission and MMI synthetic diagnostic tools and quantitatively compared to the MMI data to determine the utility of using it for mix model validation. MMI data shows the location of dopants, which are used to diagnose mix. Sensitivities of synthetic MMI images and yield to laser drive and mix levels are explored. Finally, RAGE results, clean and with mix, are compared with time-dependent streak camera data. This work is supported by US DOE/NNSA, performed at LANL, operated by LANS LLC under contract DE-AC52-06NA25396.

  14. Silicon-based products and solutions

    NASA Astrophysics Data System (ADS)

    Painchaud, Y.; Poulin, M.; Pelletier, F.; Latrasse, C.; Gagné, J.-F.; Savard, S.; Robidoux, G.; Picard, M.-.; Paquet, S.; Davidson, C.-.; Pelletier, M.; Cyr, M.; Paquet, C.; Guy, M.; Morsy-Osman, M.; Chagnon, M.; Plant, D. V.

    2014-03-01

    TeraXion started silicon photonics activities aiming at developing building blocks for new products and customized solutions. Passive and active devices have been developed including MMI couplers, power splitters, Bragg grating filters, high responsivity photodetectors, high speed modulators and variable optical attenuators. Packaging solutions including fiber attachment and hybrid integration using flip-chip were also developed. More specifically, a compact packaged integrated coherent receiver has been realized. Good performances were obtained as demonstrated by our system tests results showing transmission up to 4800 km with BER below hard FEC threshold. The package size is small but still limited by the electrical interface. Migrating to more compact RF interface would allow realizing the full benefit of this technology.

  15. Hypothyroidism during antithyroid drug treatment with methimazole is a favorable prognostic indicator in patients with Graves' disease.

    PubMed

    Choo, Young Kwang; Yoo, Won Sang; Kim, Dong Woo; Chung, Hyun-Kyung

    2010-09-01

    A major problem with antithyroid drug (ATD) therapy in Graves' disease is the high relapse rate. Therefore, clinicians have sought prognostic indicators of permanent remission. Suppression of serum thyrotropin (TSH) when ATD therapy is stopped carries a poor prognosis, but little is known regarding the significance of elevated serum TSH concentrations in the course of ATD therapy. The objective of this study was to determine if elevated serum TSH concentrations during methimazole (MMI) therapy is associated with a favorable long-term prognosis. We retrospectively studied patients with Graves' disease who were initially on MMI, in whom this drug was stopped because they had undetectable thyroid-stimulating antibodies (TSAbs) or were euthyroid after at least 24 months on MMI treatment. A strategy of high MMI doses plus T4 was not used in these patients. We identified 40 patients with elevated serum TSH concentration (>10 microIU/mL) during MMI therapy (H-TSH group). Eighty-five percent of the H-TSH group had negative tests for TSAb. The H-TSH group was sex- and age-matched with 37 patients who had similar selection criteria, but did not have elevated serum TSH concentration during MMI therapy (N-TSH group). The H-TSH and N-TSH groups were similar in gross thyroid size, percentage of patients with exophthalmos, serum free thyroxine, duration of MMI treatment, TSAb status, duration that their TSAb tests remained negative, and thyroid peroxidase antibody titers. The patients were followed for 24 months after stopping MMI. In the H-TSH group, MMI-associated hypothyroidism typically occurred after 7-8 months of treatment with daily doses of 10-15 mg MMI. No patient had severe symptoms of hypothyroidism. The percentage of patients in remission at 6, 12, and 24 months after discontinuation of MMI was 90.0, 87.5, and 85.0, respectively, in the H-TSH group and 70.3, 67.6, and 54.1, respectively, in the N-TSH group (p  <  0.05 for the comparison of groups at 6 and 12 months and p  <  0.001 for comparison of the groups at 24 months). In patients with Graves' disease who are treated with MMI for at least 2 years and become euthyroid, the occurrence of elevated serum TSH concentrations during MMI treatment is a favorable indicator for long-term remission and is independent of multiple other factors including TSAb status, duration of MMI treatment, and gross parameters of goiter size.

  16. Modified mercalli intensities for nine earthquakes in central and western Washington between 1989 and 1999

    USGS Publications Warehouse

    Brocher, Thomas M.; Dewey, James W.; Cassidy, John F.

    2017-08-15

    We determine Modified Mercalli (Seismic) Intensities (MMI) for nine onshore earthquakes of magnitude 4.5 and larger that occurred in central and western Washington between 1989 and 1999, on the basis of effects reported in postal questionnaires, the press, and professional collaborators. The earthquakes studied include four earthquakes of M5 and larger: the M5.0 Deming earthquake of April 13, 1990, the M5.0 Point Robinson earthquake of January 29, 1995, the M5.4 Duvall earthquake of May 3, 1996, and the M5.8 Satsop earthquake of July 3, 1999. The MMI are assigned using data and procedures that evolved at the U.S. Geological Survey (USGS) and its Department of Commerce predecessors and that were used to assign MMI to felt earthquakes occurring in the United States between 1931 and 1986. We refer to the MMI assigned in this report as traditional MMI, because they are based on responses to postal questionnaires and on newspaper reports, and to distinguish them from MMI calculated from data contributed by the public by way of the internet. Maximum traditional MMI documented for the M5 and larger earthquakes are VII for the 1990 Deming earthquake, V for the 1995 Point Robinson earthquake, VI for the 1996 Duvall earthquake, and VII for the 1999 Satsop earthquake; the five other earthquakes were variously assigned maximum intensities of IV, V, or VI. Starting in 1995, the Pacific Northwest Seismic Network (PNSN) published MMI maps for four of the studied earthquakes, based on macroseismic observations submitted by the public by way of the internet. With the availability now of the traditional USGS MMI interpreted for all the sites from which USGS postal questionnaires were returned, the four Washington earthquakes join a rather small group of earthquakes for which both traditional USGS MMI and some type of internet-based MMI have been assigned. The values and distributions of the traditional MMI are broadly similar to the internet-based PNSN intensities; we discuss some differences in detail that reflect differences in data-sampling procedure, differences in the procedure used to assign intensity numbers from macroseismic observations, and differences in how intensities are mapped.

  17. Agent-based human-robot interaction of a combat bulldozer

    NASA Astrophysics Data System (ADS)

    Granot, Reuven; Feldman, Maxim

    2004-09-01

    A small-scale supervised autonomous bulldozer in a remote site was developed to experience agent based human intervention. The model is based on Lego Mindstorms kit and represents combat equipment, whose job performance does not require high accuracy. The model enables evaluation of system response for different operator interventions, as well as for a small colony of semiautonomous dozers. The supervising human may better react than a fully autonomous system to unexpected contingent events, which are a major barrier to implement full autonomy. The automation is introduced as improved Man Machine Interface (MMI) by developing control agents as intelligent tools to negotiate between human requests and task level controllers as well as negotiate with other elements of the software environment. Current UGVs demand significant communication resources and constant human operation. Therefore they will be replaced by semi-autonomous human supervisory controlled systems (telerobotic). For human intervention at the low layers of the control hierarchy we suggest a task oriented control agent to take care of the fluent transition between the state in which the robot operates and the one imposed by the human. This transition should take care about the imperfections, which are responsible for the improper operation of the robot, by disconnecting or adapting them to the new situation. Preliminary conclusions from the small-scale experiments are presented.

  18. Qualitative analysis of MMI raters' scorings of medical school candidates: A matter of taste?

    PubMed

    Christensen, Mette K; Lykkegaard, Eva; Lund, Ole; O'Neill, Lotte D

    2018-05-01

    Recent years have seen leading medical educationalists repeatedly call for a paradigm shift in the way we view, value and use subjectivity in assessment. The argument is that subjective expert raters generally bring desired quality, not just noise, to performance evaluations. While several reviews document the psychometric qualities of the Multiple Mini-Interview (MMI), we currently lack qualitative studies examining what we can learn from MMI raters' subjectivity. The present qualitative study therefore investigates rater subjectivity or taste in MMI selection interview. Taste (Bourdieu 1984) is a practical sense, which makes it possible at a pre-reflective level to apply 'invisible' or 'tacit' categories of perception for distinguishing between good and bad. The study draws on data from explorative in-depth interviews with 12 purposefully selected MMI raters. We find that MMI raters spontaneously applied subjective criteria-their taste-enabling them to assess the candidates' interpersonal attributes and to predict the candidates' potential. In addition, MMI raters seemed to share a taste for certain qualities in the candidates (e.g. reflectivity, resilience, empathy, contact, alikeness, 'the good colleague'); hence, taste may be the result of an ongoing enculturation in medical education and healthcare systems. This study suggests that taste is an inevitable condition in the assessment of students' performance. The MMI set-up should therefore make room for MMI raters' taste and their connoisseurship, i.e. their ability to taste, to improve the quality of their assessment of medical school candidates.

  19. Advanced Aircraft Interfaces: The Machine Side of the Man-Machine Interface (Les Interfaces sur les Avions de Pointe: L’Aspect Machine de l’Interface Homme-Machine)

    DTIC Science & Technology

    1992-10-01

    Manager , Advanced Transport Operating Systems Program Office Langley Research Center Mail Stop 265 Hampton, VA 23665-5225 United States Programme Committee...J.H.Lind, and C.G.Burge Advanced Cockpit - Mission and Image Management 4 by J. Struck Aircrew Acceptance of Automation in the Cockpit 5 by M. Hicks and I...DESIGN CONCEPTS AND TOOLS A Systems Approach to the Advanced Aircraft Man-Machine Interface 23 by F. Armogida Management of Avionics Data in the Cockpit

  20. An MMI-based demultiplexer with reduced cross-talk

    NASA Astrophysics Data System (ADS)

    Xiao, Yueyu; He, Sailing

    2005-03-01

    The crosstalk of a multimode interference (MMI)-based demultiplexer is reduced by connecting appropriately designed cascaded MMI filters of high-order. Numerical results show that the designed demultiplexer greatly improves the bandwidth of 20 dB cross-talk loss and has an excellent performance in terms of the insertion loss and chromatic dispersion. Formed with commonly used MMI couplers, the present structure is much easier to implement than other structures.

  1. Relationship between dose of antithyroid drugs and adverse events in pediatric patients with Graves’ disease

    PubMed Central

    Yasuda, Kie; Miyoshi, Yoko; Tachibana, Makiko; Namba, Noriyuki; Miki, Kazunori; Nakata, Yukiko; Takano, Toru; Ozono, Keiichi

    2017-01-01

    Abstract. Graves’ disease (GD) accounts for a large proportion of pediatric hyperthyroidism, and the first-line treatment is antithyroid drug (ATD) therapy. Methimazole (MMI) is effective in most patients but is associated with significant adverse events (AEs). We reviewed the medical records of GD patients (n = 56) with onset age of <15 yr and investigated the relationship between MMI dose and AEs. The study population comprised 11 male and 45 female patients and the median age at diagnosis was 11 yr. All patients were initially treated with ATDs. Among the 52 patients initially treated with MMI, 20 received a low dose, and 32 received a high dose of MMI (< 0.7 vs ≥ 0.7 mg/kg/day, respectively). AEs occurred in 20% of the patients in the low-dose MMI group, and in 50% patients in the high-dose MMI group (p = 0.031). A greater variety of AEs was observed in the high-dose group. Neutropenia and rash were observed in both groups. With treatment transition to low-dose MMI according to the Japanese Society for Pediatric Endocrinology guidelines, we expect a decrease in the incidence of AEs in future. However, we should be careful as neutropenia and rash can occur independently of the MMI dose. PMID:28203042

  2. Relationship between dose of antithyroid drugs and adverse events in pediatric patients with Graves' disease.

    PubMed

    Yasuda, Kie; Miyoshi, Yoko; Tachibana, Makiko; Namba, Noriyuki; Miki, Kazunori; Nakata, Yukiko; Takano, Toru; Ozono, Keiichi

    2017-01-01

    Graves' disease (GD) accounts for a large proportion of pediatric hyperthyroidism, and the first-line treatment is antithyroid drug (ATD) therapy. Methimazole (MMI) is effective in most patients but is associated with significant adverse events (AEs). We reviewed the medical records of GD patients (n = 56) with onset age of <15 yr and investigated the relationship between MMI dose and AEs. The study population comprised 11 male and 45 female patients and the median age at diagnosis was 11 yr. All patients were initially treated with ATDs. Among the 52 patients initially treated with MMI, 20 received a low dose, and 32 received a high dose of MMI (< 0.7 vs ≥ 0.7 mg/kg/day, respectively). AEs occurred in 20% of the patients in the low-dose MMI group, and in 50% patients in the high-dose MMI group (p = 0.031). A greater variety of AEs was observed in the high-dose group. Neutropenia and rash were observed in both groups. With treatment transition to low-dose MMI according to the Japanese Society for Pediatric Endocrinology guidelines, we expect a decrease in the incidence of AEs in future. However, we should be careful as neutropenia and rash can occur independently of the MMI dose.

  3. Multiple Monochromatic Imaging (MMI) Status and Plans for LANL Campaigns on Omega and NIF

    NASA Astrophysics Data System (ADS)

    Wysocki, F. J.; Hsu, S. C.; Tregillis, I. L.; Schmitt, M. J.; Kyrala, G. A.; Martinson, D. D.; Murphy, T. J.; Mancini, R. C.; Nagayama, T.

    2011-10-01

    LANL's DIME (Defect Implosion Experiment) campaigns on Omega and NIF are aimed at obtaining improved understanding of defect-induced mix via experiments and simulations of directly driven high-Z doped plastic capsules with DD or DT gas fill. To this end, the MMI diagnostic has been identified as a key diagnostic for providing space and time-resolved density, temperature, and mix profiles. The high Z shell dopants used on Omega are Ti and V, and to be used on NIF are Ge and Se. This poster will discuss the following four areas of MMI-related work at LANL, in collaboration with UNR: (1) data and preliminary analysis of MMI data from FY11 Omega campaigns, (2) development of a capability to generate simulated MMI data from radiation- hydrodynamic simulations of ICF implosions, (3) design of an MMI instrument for NIF that will cover the photon energy range 9.5-16.9 keV which includes the Ge/Se, H- like/He-like, α/ β lines, and (4) the development of MMI data post- processing and spectroscopic analysis tools. Supported by DOE NNSA.

  4. Comparison of the multiple mini-interview with the traditional interview for U.S. emergency medicine residency applicants: a single-institution experience.

    PubMed

    Soares, William E; Sohoni, Aparajita; Hern, Herbert G; Wills, Charlotte P; Alter, Harrison J; Simon, Barry C

    2015-01-01

    The multiple mini-interview (MMI) is a validated interview technique used primarily to evaluate medical school applicants. No study has compared MMIs with traditional interviews (TIs) in the evaluation of U.S. emergency medicine residency (EMR) applicants. During the 2011-2012 interview season, a four-station MMI was incorporated into the interview process for EMR applicants at Alameda Health System-Highland Hospital (AHS). A postinterview anonymous questionnaire was offered to all applicants after they submitted their rank lists but prior to release of National Residency Matching Program results. Respondents rated their perceptions of the MMI and TI on a five-point Likert scale. McNemar chi-square test was used to explore differences in respondents' perceptions of interview styles. One hundred ten interviewees completed the survey (73%). Overall, applicants found the TI more enjoyable than the MMI process (98 [89%] compared with 48 [44%], McNemar chi-square=28.66, P<.01) and preferred the TI process to the MMI (66 [60%] compared with 9 [10%], McNemar chi-square=40.81, P<.01). Sixteen applicants (14%) indicated that the use of the MMI would negatively affect their ranking of the program. In contrast to prior studies, U.S. EMR applicants to AHS preferred the TI to the MMI. Further investigation into the use of the MMI for selecting U.S. EMR applicants is warranted.

  5. Ultra-short silicon MMI duplexer

    NASA Astrophysics Data System (ADS)

    Yi, Huaxiang; Huang, Yawen; Wang, Xingjun; Zhou, Zhiping

    2012-11-01

    The fiber-to-the-home (FTTH) systems are growing fast these days, where two different wavelengths are used for upstream and downstream traffic, typically 1310nm and 1490nm. The duplexers are the key elements to separate these wavelengths into different path in central offices (CO) and optical network unit (ONU) in passive optical network (PON). Multimode interference (MMI) has some benefits to be a duplexer including large fabrication tolerance, low-temperature dependence, and low-polarization dependence, but its size is too large to integrate in conventional case. Based on the silicon photonics platform, ultra-short silicon MMI duplexer was demonstrated to separate the 1310nm and 1490nm lights. By studying the theory of self-image phenomena in MMI, the first order images are adopted in order to keep the device short. A cascaded MMI structure was investigated to implement the wavelength splitting, where both the light of 1310nm and 1490nm was input from the same port, and the 1490nm light was coupling cross the first MMI and output at the cross-port in the device while the 1310nm light was coupling through the first and second MMI and output at the bar-port in the device. The experiment was carried on with the SOI wafer of 340nm top silicon. The cascaded MMI was investigated to fold the length of the duplexer as short as 117μm with the extinct ratio over 10dB.

  6. The validity of a behavioural multiple-mini-interview within an assessment centre for selection into specialty training

    PubMed Central

    2014-01-01

    Background Entry into specialty training was determined by a National Assessment Centre (NAC) approach using a combination of a behavioural Multiple-Mini-Interview (MMI) and a written Situational Judgement Test (SJT). We wanted to know if interviewers could make reliable and valid decisions about the non-cognitive characteristics of candidates with the purpose of selecting them into general practice specialty training using the MMI. Second, we explored the concurrent validity of the MMI with the SJT. Methods A variance components analysis estimated the reliability and sources of measurement error. Further modelling estimated the optimal configurations for future MMI iterations. We calculated the relationship of the MMI with the SJT. Results Data were available from 1382 candidates, 254 interviewers, six MMI questions, five alternate forms of a 50-item SJT, and 11 assessment centres. For a single MMI question and one assessor, 28% of the variance between scores was due to candidate-to-candidate variation. Interviewer subjectivity, in particular the varying views that interviewer had for particular candidates accounted for 40% of the variance in scores. The generalisability co-efficient for a six question MMI was 0.7; to achieve 0.8 would require ten questions. A disattenuated correlation with the SJT (r = 0.35), and in particular a raw score correlation with the subdomain related to clinical knowledge (r = 0.25) demonstrated evidence for construct and concurrent validity. Less than two per cent of candidates would have failed the MMI. Conclusion The MMI is a moderately reliable method of assessment in the context of a National Assessment Centre approach. The largest source of error relates to aspects of interviewer subjectivity, suggesting enhanced interviewer training would be beneficial. MMIs need to be sufficiently long for precise comparison for ranking purposes. In order to justify long term sustainable use of the MMI in a postgraduate assessment centre approach, more theoretical work is required to understand how written and performance based test of non-cognitive attributes can be combined, in a way that achieves acceptable generalizability, and has validity. PMID:25123968

  7. Development and validation of methods for man-made machine interface evaluation. [for shuttles and shuttle payloads

    NASA Technical Reports Server (NTRS)

    Malone, T. B.; Micocci, A.

    1975-01-01

    The alternate methods of conducting a man-machine interface evaluation are classified as static and dynamic, and are evaluated. A dynamic evaluation tool is presented to provide for a determination of the effectiveness of the man-machine interface in terms of the sequence of operations (task and task sequences) and in terms of the physical characteristics of the interface. This dynamic checklist approach is recommended for shuttle and shuttle payload man-machine interface evaluations based on reduced preparation time, reduced data, and increased sensitivity of critical problems.

  8. Hypothyroidism Enhanced Ectonucleotidases and Acetylcholinesterase Activities in Rat Synaptosomes can be Prevented by the Naturally Occurring Polyphenol Quercetin.

    PubMed

    Baldissarelli, Jucimara; Santi, Adriana; Schmatz, Roberta; Abdalla, Fátima Husein; Cardoso, Andréia Machado; Martins, Caroline Curry; Dias, Glaecir R Mundstock; Calgaroto, Nicéia Spanholi; Pelinson, Luana Paula; Reichert, Karine Paula; Loro, Vania Lucia; Morsch, Vera Maria Melchiors; Schetinger, Maria Rosa Chitolina

    2017-01-01

    Thyroid hormones have an influence on the functioning of the central nervous system. Furthermore, the cholinergic and purinergic systems also are extensively involved in brain function. In this context, quercetin is a polyphenol with antioxidant and neuroprotective properties. This study investigated the effects of (MMI)-induced hypothyroidism on the NTPDase, 5'-nucleotidase, adenosine deaminase (ADA), and acetylcholinesterase (AChE) activities in synaptosomes of rats and whether the quercetin can prevent it. MMI at a concentration of 20 mg/100 mL was administered for 90 days in the drinking water. The animals were divided into six groups: control/water (CT/W), control/quercetin 10 mg/kg, control/quercetin 25 mg/kg, methimazole/water (MMI/W), methimazole/quercetin 10 mg/kg (MMI/Q10), and methimazole/quercetin 25 mg/kg (MMI/Q25). On the 30th day, hormonal dosing was performed to confirm hypothyroidism, and the animals were subsequently treated with 10 or 25 mg/kg quercetin for 60 days. NTPDase activity was not altered in the MMI/W group. However, treatment with quercetin decreased ATP and ADP hydrolysis in the MMI/Q10 and MMI/Q25 groups. 5'-nucleotidase activity increased in the MMI/W group, but treatments with 10 or 25 mg/kg quercetin decreased 5'-nucleotidase activity. ADA activity decreased in the CT/25 and MMI/Q25 groups. Furthermore, AChE activity was reduced in all groups with hypothyroidism. In vitro tests also demonstrated that quercetin per se decreased NTPDase, 5'-nucleotidase, and AChE activities. This study demonstrated changes in the 5'-nucleotidase and AChE activities indicating that purinergic and cholinergic neurotransmission are altered in this condition. In addition, quercetin can alter these parameters and may be a promising natural compound with important neuroprotective actions in hypothyroidism.

  9. MMI attenuation and historical earthquakes in the basin and range province of western North America

    USGS Publications Warehouse

    Bakun, W.H.

    2006-01-01

    Earthquakes in central Nevada (1932-1959) were used to develop a modified Mercalli intensity (MMI) attenuation model for estimating moment magnitude M for earthquakes in the Basin and Range province of interior western North America. M is 7.4-7.5 for the 26 March 1872 Owens Valley, California, earthquake, in agreement with Beanland and Clark's (1994) M 7.6 that was estimated from geologic field observations. M is 7.5 for the 3 May 1887 Sonora, Mexico, earthquake, in agreement with Natali and Sbar's (1982) M 7.4 and Suter's (2006) M 7.5, both estimated from geologic field observations. MMI at sites in California for earthquakes in the Nevada Basin and Range apparently are not much affected by the Sierra Nevada except at sites near the Sierra Nevada where MMI is reduced. This reduction in MMI is consistent with a shadow zone produced by the root of the Sierra Nevada. In contrast, MMI assignments for earthquakes located in the eastern Sierra Nevada near the west margin of the Basin and Range are greater than predicted at sites in California. These higher MMI values may result from critical reflections due to layering near the base of the Sierra Nevada.

  10. The multiple mini-interview for selecting medical residents: first experience in the Middle East region.

    PubMed

    Ahmed, Ashraf; Qayed, Khalil Ibrahim; Abdulrahman, Mahera; Tavares, Walter; Rosenfeld, Jack

    2014-08-01

    Numerous studies have shown that multiple mini-interviews (MMI) provides a standard, fair, and more reliable method for assessing applicants. This article presents the first MMI experience for selection of medical residents in the Middle East culture and an Arab country. In 2012, we started using the MMI in interviewing applicants to the residency program of Dubai Health Authority. This interview process consisted of eight, eight-minute structured interview scenarios. Applicants rotated through the stations, each with its own interviewer and scenario. They read the scenario and were requested to discuss the issues with the interviewers. Sociodemographic and station assessment data provided for each applicant were analyzed to determine whether the MMI was a reliable assessment of the non-clinical attributes in the present setting of an Arab country. One hundred and eighty-seven candidates from 27 different countries were interviewed for Dubai Residency Training Program using MMI. They were graduates of 5 medical universities within United Arab Emirates (UAE) and 60 different universities outside UAE. With this applicant's pool, a MMI with eight stations, produced absolute and relative reliability of 0.8 and 0.81, respectively. The person × station interaction contributed 63% of the variance components, the person contributed 34% of the variance components, and the station contributed 2% of the variance components. The MMI has been used in numerous universities in English speaking countries. The MMI evaluates non-clinical attributes and this study provides further evidence for its reliability but in a different country and culture. The MMI offers a fair and more reliable assessment of applicants to medical residency programs. The present data show that this assessment technique applied in a non-western country and Arab culture still produced reliable results.

  11. All-fiber tunable MMI fiber laser

    NASA Astrophysics Data System (ADS)

    Antonio-Lopez, J. E.; Castillo-Guzman, A.; May-Arrioja, D. A.; Selvas-Aguilar, R.; LiKamWa, P.

    2009-05-01

    We report on a novel tuning mechanism to fabricate an all-fiber tunable laser based on multimode interference (MMI) effects. It is well known that the wavelength response of MMI devices exhibits a linear dependence when the length of the multimode fiber (MMF) section. Therefore, tuning in the MMI filter is achieved using a ferrule (capillary tube of 127 μm diameter) filled with a liquid with a higher refractive index than that of the ferrule, which creates a variable liquid MMF. This liquid MMF is used to increase the effective length of the MMI filter and tuning takes place. Using this simple scheme, a tuning range of 30 nm was easily achieved, with very small insertion losses. The filter was tested within a typical Erbium doped fiber (EDF) ring laser cavity, and a tunable EDF laser covering the full C-band was demonstrated. The advantage of our laser is of course the simplicity of the tunable MMI filter, which results in an inexpensive tunable fiber laser.

  12. UIVerify: A Web-Based Tool for Verification and Automatic Generation of User Interfaces

    NASA Technical Reports Server (NTRS)

    Shiffman, Smadar; Degani, Asaf; Heymann, Michael

    2004-01-01

    In this poster, we describe a web-based tool for verification and automatic generation of user interfaces. The verification component of the tool accepts as input a model of a machine and a model of its interface, and checks that the interface is adequate (correct). The generation component of the tool accepts a model of a given machine and the user's task, and then generates a correct and succinct interface. This write-up will demonstrate the usefulness of the tool by verifying the correctness of a user interface to a flight-control system. The poster will include two more examples of using the tool: verification of the interface to an espresso machine, and automatic generation of a succinct interface to a large hypothetical machine.

  13. The Body-Machine Interface: A new perspective on an old theme

    PubMed Central

    Casadio, Maura; Ranganathan, Rajiv; Mussa-Ivaldi, Ferdinando A.

    2012-01-01

    Body-machine interfaces establish a way to interact with a variety of devices, allowing their users to extend the limits of their performance. Recent advances in this field, ranging from computer-interfaces to bionic limbs, have had important consequences for people with movement disorders. In this article, we provide an overview of the basic concepts underlying the body-machine interface with special emphasis on their use for rehabilitation and for operating assistive devices. We outline the steps involved in building such an interface and we highlight the critical role of body-machine interfaces in addressing theoretical issues in motor control as well as their utility in movement rehabilitation. PMID:23237465

  14. Validating MMI Scores: Are We Measuring Multiple Attributes?

    ERIC Educational Resources Information Center

    Oliver, Tom; Hecker, Kent; Hausdorf, Peter A.; Conlon, Peter

    2014-01-01

    The multiple mini-interview (MMI) used in health professional schools' admission processes is reported to assess multiple non-cognitive constructs such as ethical reasoning, oral communication, or problem evaluation. Though validation studies have been performed with total MMI scores, there is a paucity of information regarding how well MMI…

  15. Novel spiroimidazopyridine derivative SAK3 improves methimazole-induced cognitive deficits in mice.

    PubMed

    Noreen, Husain; Yabuki, Yasushi; Fukunaga, Kohji

    2017-09-01

    Methimazole (MMI) is a first-line therapy used to manage hyperthyroidism and Graves' disease. Despite its therapeutic benefit, chronic MMI administration can lead to hypothyroidism and perturb brain homeostasis in patients, resulting in neuropsychiatric disorders such as depression and cognitive dysfunction. We recently developed the spiroimidazopyridine derivative SAK3 as cognitive enhancer; however, mechanisms underlying its activity remained unclear. Here, we show that SAK3 potentially improves cognitive impairment seen following MMI-induced hypothyroidism. Twenty-four hours after MMI (75 mg/kg, i.p.) treatment, we administered SAK3 (0.1, 0.5 and 1 mg/kg, p.o.) to mice daily for 7 days. MMI treatment alone disrupted olfactory bulb (OB) glomerular structure, as assessed by staining with the olfactory marker protein (OMP), reduced the number of choline acetyl transferase (ChAT)-immunoreactive neurons in medial septum (MS), and significantly impaired cognition. SAK3 (0.5 and 1 mg/kg, p.o.) administration significantly restored the number of cholinergic MS neurons in MMI-treated mice, and SAK3 treatment at a higher dose significantly improved cognitive deficits seen in MMI-treated control mice. Overall, our study suggests that SAK3 treatment could antagonize such impairment in patients with hypothyroidism. Copyright © 2017 Elsevier Ltd. All rights reserved.

  16. The fairness, predictive validity and acceptability of multiple mini interview in an internationally diverse student population--a mixed methods study.

    PubMed

    Kelly, Maureen E; Dowell, Jon; Husbands, Adrian; Newell, John; O'Flynn, Siun; Kropmans, Thomas; Dunne, Fidelma P; Murphy, Andrew W

    2014-12-21

    International medical students, those attending medical school outside of their country of citizenship, account for a growing proportion of medical undergraduates worldwide. This study aimed to establish the fairness, predictive validity and acceptability of Multiple Mini Interview (MMI) in an internationally diverse student population. This was an explanatory sequential, mixed methods study. All students in First Year Medicine, National University of Ireland Galway 2012 were eligible to sit a previously validated 10 station MMI. Quantitative data comprised: demographics, selection tool scores and First Year Assessment scores. Qualitative data comprised separate focus groups with MMI Assessors, EU and Non-EU students. 109 students participated (45% of class). Of this 41.3% (n = 45) were Non-EU and 35.8% (n = 39) did not have English as first language. Age, gender and socioeconomic class did not impact on MMI scores. Non-EU students and those for whom English was not a first language achieved significantly lower scores on MMI than their EU and English speaking counterparts (difference in mean 11.9% and 12.2% respectively, P<0.001). MMI score was associated with English language proficiency (IELTS) (r = 0.5, P<0.01). Correlations emerged between First Year results and IELTS (r = 0.44; p = 0.006; n = 38) and EU school exit exam (r = 0.52; p<0.001; n = 56). MMI predicted EU student OSCE performance (r = 0.27; p = 0.03; n = 64). In the analysis of focus group data two overarching themes emerged: Authenticity and Cultural Awareness. MMI was considered a highly authentic assessment that offered a deeper understanding of the applicant than traditional tools, with an immediate relevance to clinical practice. Cultural specificity of some stations and English language proficiency were seen to disadvantage international students. Recommendations included cultural awareness training for MMI assessors, designing and piloting culturally neutral stations, lengthening station duration and providing high quality advance information to candidates. MMI is a welcome addition to assessment armamentarium for selection, particularly with regard to stakeholder acceptability. Understanding the mediating and moderating influences for differences in performance of international candidates is essential to ensure that MMI complies with the metrics of good assessment practice and principles of both distributive and procedural justice for all applicants, irrespective of nationality and cultural background.

  17. Layout Design of Human-Machine Interaction Interface of Cabin Based on Cognitive Ergonomics and GA-ACA.

    PubMed

    Deng, Li; Wang, Guohua; Yu, Suihuai

    2016-01-01

    In order to consider the psychological cognitive characteristics affecting operating comfort and realize the automatic layout design, cognitive ergonomics and GA-ACA (genetic algorithm and ant colony algorithm) were introduced into the layout design of human-machine interaction interface. First, from the perspective of cognitive psychology, according to the information processing process, the cognitive model of human-machine interaction interface was established. Then, the human cognitive characteristics were analyzed, and the layout principles of human-machine interaction interface were summarized as the constraints in layout design. Again, the expression form of fitness function, pheromone, and heuristic information for the layout optimization of cabin was studied. The layout design model of human-machine interaction interface was established based on GA-ACA. At last, a layout design system was developed based on this model. For validation, the human-machine interaction interface layout design of drilling rig control room was taken as an example, and the optimization result showed the feasibility and effectiveness of the proposed method.

  18. Layout Design of Human-Machine Interaction Interface of Cabin Based on Cognitive Ergonomics and GA-ACA

    PubMed Central

    Deng, Li; Wang, Guohua; Yu, Suihuai

    2016-01-01

    In order to consider the psychological cognitive characteristics affecting operating comfort and realize the automatic layout design, cognitive ergonomics and GA-ACA (genetic algorithm and ant colony algorithm) were introduced into the layout design of human-machine interaction interface. First, from the perspective of cognitive psychology, according to the information processing process, the cognitive model of human-machine interaction interface was established. Then, the human cognitive characteristics were analyzed, and the layout principles of human-machine interaction interface were summarized as the constraints in layout design. Again, the expression form of fitness function, pheromone, and heuristic information for the layout optimization of cabin was studied. The layout design model of human-machine interaction interface was established based on GA-ACA. At last, a layout design system was developed based on this model. For validation, the human-machine interaction interface layout design of drilling rig control room was taken as an example, and the optimization result showed the feasibility and effectiveness of the proposed method. PMID:26884745

  19. Future developments in brain-machine interface research.

    PubMed

    Lebedev, Mikhail A; Tate, Andrew J; Hanson, Timothy L; Li, Zheng; O'Doherty, Joseph E; Winans, Jesse A; Ifft, Peter J; Zhuang, Katie Z; Fitzsimmons, Nathan A; Schwarz, David A; Fuller, Andrew M; An, Je Hi; Nicolelis, Miguel A L

    2011-01-01

    Neuroprosthetic devices based on brain-machine interface technology hold promise for the restoration of body mobility in patients suffering from devastating motor deficits caused by brain injury, neurologic diseases and limb loss. During the last decade, considerable progress has been achieved in this multidisciplinary research, mainly in the brain-machine interface that enacts upper-limb functionality. However, a considerable number of problems need to be resolved before fully functional limb neuroprostheses can be built. To move towards developing neuroprosthetic devices for humans, brain-machine interface research has to address a number of issues related to improving the quality of neuronal recordings, achieving stable, long-term performance, and extending the brain-machine interface approach to a broad range of motor and sensory functions. Here, we review the future steps that are part of the strategic plan of the Duke University Center for Neuroengineering, and its partners, the Brazilian National Institute of Brain-Machine Interfaces and the École Polytechnique Fédérale de Lausanne (EPFL) Center for Neuroprosthetics, to bring this new technology to clinical fruition.

  20. Clinical Study of 27 Patients with Medial Medullary Infarction.

    PubMed

    Akimoto, Takayoshi; Ogawa, Katsuhiko; Morita, Akihiko; Suzuki, Yutaka; Kamei, Satoshi

    2017-10-01

    Medial medullary infarction (MMI) is a rare ischemic stroke. Frequency of each neurological finding in MMI was different in each study. We retrospectively evaluated the medical records of patients with cerebral infarction who were admitted between March 1998 and October 2015. Patients in our study were diagnosed as having MMI by magnetic resonance image examination. Of 2727 patients with ischemic stroke, 27 patients (20 males and 7 females) had MMI. The MMI was complicated by infarcts located in the pons (n = 6), cerebellum (n = 2), and lateral medulla (n = 1). One patient had bilateral MMI. Large-artery atherosclerosis was the most common etiology. Motor weakness of the extremities was the most common neurological finding. Diminished contralateral superficial sensation was more common than diminished contralateral vibratory sensation, and these 2 types of sensory disturbance were often complicated. The patients with large MMI significantly more often accompanied diminished touch (P = .003), pain (P = .017), and vibratory (P = .019) sensation. Facial weakness was shown more common contralateral to the infarcts than ipsilateral (n = 8 contralateral, n = 1 ipsilateral). Lingual palsy was also more common contralateral to the lesions (n = 3 contralateral, n = 1 ipsilateral). One patient alone fulfilled the classical Dejerine triad. In MMI, motor weakness of extremities was commonly shown, and complication of diminished sensations indicated the large infarcts. As for facial weakness and lingual palsy, the supranuclear type was more prominent than the infranuclear type. Copyright © 2017 National Stroke Association. Published by Elsevier Inc. All rights reserved.

  1. An exploration of the relationship between emotional intelligence (EI) and the Multiple Mini-Interview (MMI).

    PubMed

    Yen, Wendy; Hovey, Richard; Hodwitz, Kathryn; Zhang, Su

    2011-03-01

    The present study explored the relationship between the Multiple Mini-Interview (MMI) admissions process and the Bar-On EQ-i emotional intelligence (EI) instrument in order to investigate the potential for the EQ-i to serve as a proxy measure to the MMI. Participants were 196 health science candidates who completed both the MMI and the EQ-i as part of their admissions procedure at the Michener Institute for Applied Health Sciences. Three types of analyses were conducted to examine the relationship between the two tools: reliability analyses, correlational analyses, and a t-test. The tools were found to be moderately reliable. No significant relationships were found between the MMI and the EQ-i at the total or subscale level. The ability of the EQ-i to discriminate between accepted and not-accepted students was also not supported. These findings do not support the use of the EQ-i as a potential pre-screening tool for the MMI, but rather highlight the need to exercise caution when using emotional intelligence instruments for high-stakes admissions purposes.

  2. Semantic Integration for Marine Science Interoperability Using Web Technologies

    NASA Astrophysics Data System (ADS)

    Rueda, C.; Bermudez, L.; Graybeal, J.; Isenor, A. W.

    2008-12-01

    The Marine Metadata Interoperability Project, MMI (http://marinemetadata.org) promotes the exchange, integration, and use of marine data through enhanced data publishing, discovery, documentation, and accessibility. A key effort is the definition of an Architectural Framework and Operational Concept for Semantic Interoperability (http://marinemetadata.org/sfc), which is complemented with the development of tools that realize critical use cases in semantic interoperability. In this presentation, we describe a set of such Semantic Web tools that allow performing important interoperability tasks, ranging from the creation of controlled vocabularies and the mapping of terms across multiple ontologies, to the online registration, storage, and search services needed to work with the ontologies (http://mmisw.org). This set of services uses Web standards and technologies, including Resource Description Framework (RDF), Web Ontology language (OWL), Web services, and toolkits for Rich Internet Application development. We will describe the following components: MMI Ontology Registry: The MMI Ontology Registry and Repository provides registry and storage services for ontologies. Entries in the registry are associated with projects defined by the registered users. Also, sophisticated search functions, for example according to metadata items and vocabulary terms, are provided. Client applications can submit search requests using the WC3 SPARQL Query Language for RDF. Voc2RDF: This component converts an ASCII comma-delimited set of terms and definitions into an RDF file. Voc2RDF facilitates the creation of controlled vocabularies by using a simple form-based user interface. Created vocabularies and their descriptive metadata can be submitted to the MMI Ontology Registry for versioning and community access. VINE: The Vocabulary Integration Environment component allows the user to map vocabulary terms across multiple ontologies. Various relationships can be established, for example exactMatch, narrowerThan, and subClassOf. VINE can compute inferred mappings based on the given associations. Attributes about each mapping, like comments and a confidence level, can also be included. VINE also supports registering and storing resulting mapping files in the Ontology Registry. The presentation will describe the application of semantic technologies in general, and our planned applications in particular, to solve data management problems in the marine and environmental sciences.

  3. Birth defects after use of antithyroid drugs in early pregnancy: a Swedish nationwide study.

    PubMed

    Andersen, Stine Linding; Lönn, Stefan; Vestergaard, Peter; Törring, Ove

    2017-10-01

    Antithyroid drugs (ATDs) may have teratogenic effects, but more evidence is needed on the risk and types of birth defects after the use of methimazole (MMI) and propylthiouracil (PTU). This study aimed to evaluate the association between the use of ATDs in early pregnancy and birth defects. Swedish nationwide register-based cohort study. The study included 684 340 children live-born in Sweden from 2006 to 2012. Exposure groups defined by maternal ATD use in early pregnancy were MMI ( n  = 162); PTU ( n  = 218); MMI and PTU ( n  = 66); ATD before or after, but not in pregnancy ( n  = 1551) and non-exposed (never ATD ( n  = 682 343)). Outcome was cumulative incidence of birth defects diagnosed before two years of age. The cumulative incidence of birth defects was not significantly different in children exposed to MMI (6.8%, P  = 0.6) or PTU (6.4%, P  = 0.4) vs non-exposed (8.0%). For subtypes of birth defects, MMI was associated with an increased incidence of septal heart defects ( P  = 0.02). PTU was associated with ear ( P  = 0.005) and obstructive urinary system malformations ( P  = 0.006). A case of choanal atresia was observed after exposure to both MMI and PTU. The incidence of birth defects in children born to mothers who received ATD before or after, but not in pregnancy, was 8.8% and not significantly different from non-exposed ( P  = 0.3), MMI exposed ( P  = 0.4) or PTU exposed ( P  = 0.2). MMI and PTU were associated with subtypes of birth defects previously reported, but the frequency of ATD exposure in early pregnancy was low and severe malformations described in the MMI embryopathy were rarely observed. © 2017 European Society of Endocrinology.

  4. Multiple mini-interviews: same concept, different approaches.

    PubMed

    Knorr, Mirjana; Hissbach, Johanna

    2014-12-01

    Increasing numbers of educational institutions in the medical field choose to replace their conventional admissions interviews with a multiple mini-interview (MMI) format because the latter has superior reliability values and reduces interviewer bias. As the MMI format can be adapted to the conditions of each institution, the question of under which circumstances an MMI is most expedient remains unresolved. This article systematically reviews the existing MMI literature to identify the aspects of MMI design that have impact on the reliability, validity and cost-efficiency of the format. Three electronic databases (OVID, PubMed, Web of Science) were searched for any publications in which MMIs and related approaches were discussed. Sixty-six publications were included in the analysis. Forty studies reported reliability values. Generally, raising the number of stations has more impact on reliability than raising the number of raters per station. Other factors with positive influence include the exclusion of stations that are too easy, and the use of normative anchored rating scales or skills-based rater training. Data on criterion-related validities and analyses of dimensionality were found in 31 studies. Irrespective of design differences, the relationship between MMI results and academic measures is small to zero. The McMaster University MMI predicts in-programme and licensing examination performance. Construct validity analyses are mostly exploratory and their results are inconclusive. Seven publications gave information on required resources or provided suggestions on how to save costs. The most relevant cost factors that are additional to those of conventional interviews are the costs of station development and actor payments. The MMI literature provides useful recommendations for reliable and cost-efficient MMI designs, but some important aspects have not yet been fully explored. More theory-driven research is needed concerning dimensionality and construct validity, the predictive validity of MMIs other than those of McMaster University, the comparison of station types, and a cost-efficient station development process. © 2014 John Wiley & Sons Ltd.

  5. Modified Mercalli intensities (MMI) for large earthquakes near New Madrid, Missouri, in 1811-1812 and near Charleston, South Carolina, in 1886

    USGS Publications Warehouse

    Bakun, W.H.; Johnston, A.C.; Hopper, M.G.

    2002-01-01

    Large historical earthquakes occurred in the eastern United States on December 16, 1811 near New Madrid, MO, on January 23, 1812 near New Madrid, MO, on February 7, 1812 near New Madrid, MO, and on September 1, 1886 near Charleston, SC. Modified Mercalli Intensity (MMI) assignments for these earthquakes were used by Bakun et al. (submitted) to estimate the location and moment magnitude M of these earthquakes from MMI observations. The MMI assignments used by Bakun et al. (submitted) are listed in this report.

  6. [Multiple mini interviews before the occupation of main training posts in paediatrics].

    PubMed

    Hertel, Niels Thomas; Bjerager, Mia; Boas, Malene; Boisen, Kirsten A; Børch, Klaus; Frederiksen, Marianne Sjølin; Holm, Kirsten; Grum-Nymann, Anette; Johnsen, Martin M; Whitehouse, Stine; Balslev, Thomas

    2013-09-09

    Interviews are mandatory in Denmark when selecting doctors for training positions. We used multiple mini interviews (MMI) at four recruitment rounds for the main training posts in paediatrics. In total, 125 candidates were evaluated and assessed by CV and MMI (4-5 stations). Reliability for individual stations in MMI assessed by Cronbach's alpha was adequate (0.63-0.92). The overall reliability assessed by G-theory was lower, suggesting that different skills were tested. The acceptability was high. Our experiences with MMI suggest good feasibility and reliability. An increasing number of stations may improve the overall reliability.

  7. A simple brain atrophy measure improves the prediction of malignant middle cerebral artery infarction by acute DWI lesion volume.

    PubMed

    Beck, Christoph; Kruetzelmann, Anna; Forkert, Nils D; Juettler, Eric; Singer, Oliver C; Köhrmann, Martin; Kersten, Jan F; Sobesky, Jan; Gerloff, Christian; Fiehler, Jens; Schellinger, Peter D; Röther, Joachim; Thomalla, Götz

    2014-06-01

    In patients with malignant middle cerebral artery infarction (MMI) decompressive surgery within 48 h improves functional outcome. In this respect, early identification of patients at risk of developing MMI is crucial. While the acute diffusion weighted imaging (DWI) lesion volume was found to predict MMI with high predictive values, the potential impact of preexisting brain atrophy on the course of space-occupying middle cerebral artery (MCA) infarction and the development of MMI remains unclear. We tested the hypothesis that the combination of the acute DWI lesion volume with simple measures of brain atrophy improves the early prediction of MMI. Data from a prospective, multicenter, observational study, which included patients with acute middle cerebral artery main stem occlusion studied by MRI within 6 h of symptom onset, was analyzed retrospectively. The development of MMI was defined according to the European randomized controlled trials of decompressive surgery. Acute DWI lesion volume, as well as brain and cerebrospinal fluid volume (CSF) were delineated. The intercaudate distance (ICD) was assessed as a linear brain atrophy marker by measuring the hemi-ICD of the intact hemisphere to account for local brain swelling. Binary logistic regression analysis was used to identify significant predictors of MMI. Cut-off values were determined by Classification and Regression Trees analysis. Sensitivity, specificity, positive predictive value (PPV), and negative predictive value (NPV) of the resulting models were calculated. Twenty-one (18 %) of 116 patients developed a MMI. Malignant middle cerebral artery infarctions patients had higher National Institutes of Health Stroke Scale scores on admission and presented more often with combined occlusion of the internal carotid artery and MCA. There were no differences in brain and CSF volume between the two groups. Diffusion weighted imaging lesion volume was larger (p < 0.001), while hemi-ICD was smaller (p = 0.029) in MMI patients. Inclusion of hemi-ICD improved the prediction of MMI. Best cut-off values to predict the development of MMI were DWI lesion volume > 87 ml and hemi-ICD ≤ 9.4 mm. The addition of hemi-ICD to the decision tree strongly increased PPV (0.93 vs. 0.70) resulting in a reduction of false positive findings from 7/23 (30 %) to 1/15 (7 %), while there were only slight changes in specificity, sensitivity and NPV. The absolute number of correct classifications increased by 4 (3.4 %). The integration of hemi-ICD as a linear marker of brain atrophy, that can easily be assessed in an emergency setting, may improve the prediction of MMI by lesion volume based predictive models.

  8. Regulation of endotoxin-induced inhibition of macrophage migration by fresh serum.

    PubMed Central

    Heilman, D H

    1977-01-01

    Purified endotoxin (LPS) caused macrophage migration inhibition (MMI) in capillary tube cultures of guinea pig peritoneal macrophages in medium prepared with 15% fresh-frozen guinea pig serum. The inactivation of serum by heating at 56 degrees C for 30 min or by zymosan absorption prevented LPS-induced MMI. LPS was fully inhibitory in fresh C4-deficient guinea pig serum. Heat treatment of normal serum at 50 to 52 degrees C for 30 min to inactivate the alternate complement (C) pathway prevented or significantly decreased LPS-induced MMI, but heating C4-deficient serum at 50 to 52 degrees C for 30 min prevented LPS-MMI in all instances. These results suggest that the reaction was effected via the alternate C pathway but that some inhibition of migration was permitted via the classical C pathway, presumably due to antibodies for LPS in some normal sera. Pretreatment of normal serum with cobra venom factor decreased or prevented LPS-MMI in most instances, but similar results were obtained with C4-deficient serum. Experiments with chelated sera were unsuccessful because of the immobilization of macrophages by 10 mM ethylenediamine-tetraacetic acid and by 10 mM Mg-ethyleneglycol-bis (beta-aminoethyl)-N,N-tetraacetic acid. Low doses of concanavalin A and staphylococcal enterotoxin B and large doses of pokeweed mitogen caused MMI in "inactivated serum" medium, but MMI was enhanced in fresh serum. PMID:330407

  9. Future developments in brain-machine interface research

    PubMed Central

    Lebedev, Mikhail A; Tate, Andrew J; Hanson, Timothy L; Li, Zheng; O'Doherty, Joseph E; Winans, Jesse A; Ifft, Peter J; Zhuang, Katie Z; Fitzsimmons, Nathan A; Schwarz, David A; Fuller, Andrew M; An, Je Hi; Nicolelis, Miguel A L

    2011-01-01

    Neuroprosthetic devices based on brain-machine interface technology hold promise for the restoration of body mobility in patients suffering from devastating motor deficits caused by brain injury, neurologic diseases and limb loss. During the last decade, considerable progress has been achieved in this multidisciplinary research, mainly in the brain-machine interface that enacts upper-limb functionality. However, a considerable number of problems need to be resolved before fully functional limb neuroprostheses can be built. To move towards developing neuroprosthetic devices for humans, brain-machine interface research has to address a number of issues related to improving the quality of neuronal recordings, achieving stable, long-term performance, and extending the brain-machine interface approach to a broad range of motor and sensory functions. Here, we review the future steps that are part of the strategic plan of the Duke University Center for Neuroengineering, and its partners, the Brazilian National Institute of Brain-Machine Interfaces and the École Polytechnique Fédérale de Lausanne (EPFL) Center for Neuroprosthetics, to bring this new technology to clinical fruition. PMID:21779720

  10. Antithyroid drug-related hepatotoxicity in hyperthyroidism patients: a population-based cohort study

    PubMed Central

    Wang, Meng-Ting; Lee, Wan-Ju; Huang, Tien-Yu; Chu, Che-Li; Hsieh, Chang-Hsun

    2014-01-01

    Aims The evidence of hepatotoxicity of antithyroid drugs (ATDs) is limited to case reports or spontaneous reporting. This study aimed to quantify the incidence and comparative risks of hepatotoxicity for methimazole (MMI)/carbimazole (CBM) vs. propylthiouracil (PTU) in a population-based manner. Methods We conducted a cohort study of hyperthyroidism patients initially receiving MMI/CBM or PTU between 1 January 2004 and 31 December 2008 using the Taiwan National Health Insurance Research Database. The examined hepatotoxicity consisted of cholestasis, non-infectious hepatitis, acute liver failure and liver transplant, with the incidences and relative risks being quantified by Poisson exact methods and Cox proportional hazard models, respectively. Results The study cohort comprised 71 379 ATD initiators, with a median follow-up of 196 days. MMI/CBM vs. PTU users had a higher hepatitis incidence rate (3.17/1000 vs. 1.19/1000 person-years) but a lower incidence of acute liver failure (0.32/1000 vs. 0.68/1000 person-years). The relative risk analysis indicated that any use of MMI/CBM was associated with a 2.89-fold (95% CI 1.81, 4.60) increased hepatitis risk compared with PTU, with the risk increasing to 5.08-fold for high dose MMI/CBM (95% CI 3.15, 8.18). However, any MMI/CBM use vs. PTU was not related to an increased risk of cholestasis (adjusted hazard ratio [HR] 1.14, 95% CI 0.40, 3.72) or acute liver failure (adjusted HR 0.54, 95% CI 0.24, 1.22). Conclusions MMI/CBM and PTU exert dissimilar incidence rates of hepatotoxicity. Compared to PTU, MMI/CBM are associated in a dose-dependent manner with an increased risk for hepatitis while the risks are similar for acute liver failure and cholestasis. PMID:25279406

  11. Student nurse selection and predictability of academic success: The Multiple Mini Interview project.

    PubMed

    Gale, Julia; Ooms, Ann; Grant, Robert; Paget, Kris; Marks-Maran, Di

    2016-05-01

    With recent reports of public enquiries into failure to care, universities are under pressure to ensure that candidates selected for undergraduate nursing programmes demonstrate academic potential as well as characteristics and values such as compassion, empathy and integrity. The Multiple Mini Interview (MMI) was used in one university as a way of ensuring that candidates had the appropriate numeracy and literacy skills as well as a range of communication, empathy, decision-making and problem-solving skills as well as ethical insights and integrity, initiative and team-work. To ascertain whether there is evidence of bias in MMIs (gender, age, nationality and location of secondary education) and to determine the extent to which the MMI is predictive of academic success in nursing. A longitudinal retrospective analysis of student demographics, MMI data and the assessment marks for years 1, 2 and 3. One university in southwest London. One cohort of students who commenced their programme in September 2011, including students in all four fields of nursing (adult, child, mental health and learning disability). Inferential statistics and a Bayesian Multilevel Model. MMI in conjunction with MMI numeracy test and MMI literacy test shows little or no bias in terms of ages, gender, nationality or location of secondary school education. Although MMI in conjunction with numeracy and literacy testing is predictive of academic success, it is only weakly predictive. The MMI used in conjunction with literacy and numeracy testing appears to be a successful technique for selecting candidates for nursing. However, other selection methods such as psychological profiling or testing of emotional intelligence may add to the extent to which selection methods are predictive of academic success on nursing. Copyright © 2016 Elsevier Ltd. All rights reserved.

  12. Mode-medium instability and its correction with a Gaussian-reflectivity mirror

    NASA Technical Reports Server (NTRS)

    Webster, K. L.; Sung, C. C.

    1992-01-01

    A high-power CO2 laser beam is known to deteriorate after a few microseconds due to a mode-medium instability (MMI) which results from an intensity-dependent heating rate related to the vibrational-to-translational decay of the upper and lower CO2 lasing levels. An iterative numerical technique is developed to model the time evolution of the beam as it is affected by the MMI. The technique is used to study the MMI in an unstable CO2 resonator with a hard-edge output mirror for different parameters like the Fresnel number and the gas density. The results show that the mode of the hard edge unstable resonator deteriorates because of the diffraction ripples in the mode. A Gaussian-reflectivity mirror was used to correct the MMI. This mirror produces a smoother intensity profile which significantly reduces the effects of the MMI. Quantitative results on peak density variation and beam quality are presented.

  13. Mode-medium instability and its correction with a Gaussian reflectivity mirror

    NASA Technical Reports Server (NTRS)

    Webster, K. L.; Sung, C. C.

    1990-01-01

    A high power CO2 laser beam is known to deteriorate after a few microseconds due to a mode-medium instability (MMI) which results from an intensity dependent heating rate related to the vibrational-to-translational decay of the upper and lower CO2 lasing levels. An iterative numerical technique is developed to model the time evolution of the beam as it is affected by the MMI. The technique is used to study the MMI in an unstable CO2 resonator with a hard-edge output mirror for different parameters like the Fresnel number and the gas density. The results show that the mode of the hard edge unstable resonator deteriorates because of the diffraction ripples in the mode. A Gaussian-reflectivity mirror was used to correct the MMI. This mirror produces a smoother intensity profile which significantly reduces the effects of the MMI. Quantitative results on peak density variation and beam quality are presented.

  14. Silicon Nitride Grating Coupler with Flexible Bandwidth Incorporating a Serially Concatenated Multimode Interference Filter

    NASA Astrophysics Data System (ADS)

    Kim, Woo-Ju; Lee, Hak-Soon; Lee, Sang-Shin

    2012-04-01

    A compact silicon nitride grating coupler with flexible bandwidth was demonstrated taking advantage of a basic grating integrated with a serially connected multistage multimode interference (MMI) filter. The spectral response could be tailored by varying the order of the MMI filter, without affecting the basic grating structure. The dependence of the spectral response of the proposed device on the order of the MMI stage was thoroughly investigated. As regards the fabricated grating coupler with a four-stage MMI filter, the observed spectral bandwidth was efficiently altered from 53 to 21 nm in the ˜1550 nm spectral band.

  15. Silicon cross-connect filters using microring resonator coupled multimode-interference-based waveguide crossings.

    PubMed

    Xu, Fang; Poon, Andrew W

    2008-06-09

    We report silicon cross-connect filters using microring resonator coupled multimode-interference (MMI) based waveguide crossings. Our experiments reveal that the MMI-based cross-connect filters impose lower crosstalk at the crossing than the conventional cross-connect filters using plain crossings, while offering a nearly symmetric resonance line shape in the drop-port transmission. As a proof-of-concept for cross-connection applications, we demonstrate on a silicon-on-insulator substrate (i) a 4-channel 1 x 4 linear-cascaded MMI-based cross-connect filter, and (ii) a 2-channel 2 x 2 array-cascaded MMI-based cross-connect filter.

  16. Dual-wavelength noise-like pulse generation in passively mode-locked all-fiber laser based on MMI effect

    NASA Astrophysics Data System (ADS)

    Shi, Guannan; Fu, Shijie; Sheng, Quan; Shi, Wei; Yao, Jianquan

    2018-02-01

    We report on the generation of dual-wavelength noise-like pulse (NLP) from a passively mode-locked all-fiber laser based on multimode interference (MMI) effect. The theory to evaluate and design transmission spectrum of MMI filter is analyzed. A homemade MMI filter was employed in an Er-doped fiber ring laser with NPE configuration and dual-wavelength NLP at 1530 and 1600 nm was obtained with 3-dB bandwidth of 18.1 and 41.9 nm, respectively. The output had a signal-to-noise ratio higher than 35 dB and can achieve self-started operation.

  17. Comparing Simulated and Observed Spectroscopic Signatures of Mix in Omega Capsules

    NASA Astrophysics Data System (ADS)

    Tregillis, I. L.; Shah, R. C.; Hakel, P.; Cobble, J. A.; Murphy, T. J.; Krasheninnikova, N. S.; Hsu, S. C.; Bradley, P. A.; Schmitt, M. J.; Batha, S. H.; Mancini, R. C.

    2012-10-01

    The Defect-Induced Mix Experiment (DIME) campaign at Los Alamos National Laboratory uses multi-monochromatic X-ray imaging (MMI)footnotetextT. Nagayama, R.C. Mancini, R. Florido, et al, J. App. Phys. 109, 093303 (2011) to detect the migration of high-Z spectroscopic dopants into the hot core of an imploded capsule. We have developed an MMI post-processing tool for producing synthetic datasets from two- and three-dimensional Lagrangian numerical simulations of Omega and NIF shots. These synthetic datasets are of sufficient quality, and contain sufficient physics, that they can be analyzed in the same manner as actual MMI data. We have carried out an extensive comparison between simulated and observed MMI data for a series of polar direct-drive shots carried out at the Omega laser facility in January, 2011. The capsule diameter was 870 microns; the 15 micron CH ablators contained a 2 micron Ti-doped layer along the inner edge. All capsules were driven with 17 kJ; some capsules were manufactured with an equatorial ``trench'' defect. This talk will focus on the construction of spectroscopic-quality synthetic MMI datasets from numerical simulations, and their correlation with MMI measurements.

  18. Extremely small polarization beam splitter based on a multimode interference coupler with a silicon hybrid plasmonic waveguide.

    PubMed

    Guan, Xiaowei; Wu, Hao; Shi, Yaocheng; Dai, Daoxin

    2014-01-15

    A novel polarization beam splitter (PBS) with an extremely small footprint is proposed based on a multimode interference (MMI) coupler with a silicon hybrid plasmonic waveguide. The MMI section, covered with a metal strip partially, is designed to achieve mirror imaging for TE polarization. On the other hand, for TM polarization, there is almost no MMI effect since the higher-order TM modes are hardly excited due to the hybrid plasmonic effect. With this design, the whole PBS including the 1.1 μm long MMI section as well as the output section has a footprint as small as ∼1.8 μm×2.5 μm. Besides, the fabrication process is simple since the waveguide dimension is relatively large (e.g., the input/output waveguides widths w ≥300 nm and the MMI width w(MMI)=800 nm). Numerical simulations show that the designed PBS has a broad band of ∼80 nm for an ER >10 dB as well as a large fabrication tolerance to allow a silicon core width variation of -30 nm<Δw<50 nm and a metal strip width variation of -200 nm<Δw(m)<0.

  19. Earthquake Macro-zonation Based Peak Ground Acceleration, Modified Mercalli Intensity, And Type of Rocks around Matano Fault

    NASA Astrophysics Data System (ADS)

    Karnaen, Muh; Suriamihardja, D. A.; Maulana, A.; Jaya, A.

    2018-03-01

    This study aims to determine earthquake vulnerable zones. We conducted research on earthquake macro-zonation based on PGA, Modified Mercalli Intensity (MMI), and type of rocks around Matano Fault in the area of 1.60 S to 2.990 S and 120.50 E to 122.470 E. We have acquired Maximum PGA and Modified Mercalli Intensity (MMI) for each observation point on the ground from the four major earthquake events. The empirical model is used due to lack of acceleration data recorded. We tried some empirical methods, but the McGuire method is found to be acceptable for this area. The result gives the maximum variation of PGA which is ranged between 18.40 - 363.54 gals. While the variation of MMI using empirical Wald attenuation gives values ranging from 2.9 - 7.7 MMI. The most vulnerable zone is located around Sorowako city with PGA value of 326.55 gals and MMI value of 7.5 MMI. This area is between ultra-basic rock and metamorphic rock formation. The vulnerable zone is near largest earthquake 6.2 M on 15-02-2011.

  20. A low-complexity region in the YTH domain protein Mmi1 enhances RNA binding.

    PubMed

    Stowell, James A W; Wagstaff, Jane L; Hill, Chris H; Yu, Minmin; McLaughlin, Stephen H; Freund, Stefan M V; Passmore, Lori A

    2018-06-15

    Mmi1 is an essential RNA-binding protein in the fission yeast Schizosaccharomyces pombe that eliminates meiotic transcripts during normal vegetative growth. Mmi1 contains a YTH domain that binds specific RNA sequences, targeting mRNAs for degradation. The YTH domain of Mmi1 uses a noncanonical RNA-binding surface that includes contacts outside the conserved fold. Here, we report that an N-terminal extension that is proximal to the YTH domain enhances RNA binding. Using X-ray crystallography, NMR, and biophysical methods, we show that this low-complexity region becomes more ordered upon RNA binding. This enhances the affinity of the interaction of the Mmi1 YTH domain with specific RNAs by reducing the dissociation rate of the Mmi1-RNA complex. We propose that the low-complexity region influences RNA binding indirectly by reducing dynamic motions of the RNA-binding groove and stabilizing a conformation of the YTH domain that binds to RNA with high affinity. Taken together, our work reveals how a low-complexity region proximal to a conserved folded domain can adopt an ordered structure to aid nucleic acid binding. © 2018 Stowell et al.

  1. Past-behavioural versus situational questions in a postgraduate admissions multiple mini-interview: a reliability and acceptability comparison.

    PubMed

    Yoshimura, Hiroshi; Kitazono, Hidetaka; Fujitani, Shigeki; Machi, Junji; Saiki, Takuya; Suzuki, Yasuyuki; Ponnamperuma, Gominda

    2015-04-14

    The Multiple Mini-Interview (MMI) mostly uses 'Situational' Questions (SQs) as an interview format within a station, rather than 'Past-Behavioural' Questions (PBQs), which are most frequently adopted in traditional single-station personal interviews (SSPIs) for non-medical and medical selection. This study investigated reliability and acceptability of the postgraduate admissions MMI with PBQ and SQ interview formats within MMI stations. Twenty-six Japanese medical graduates, first completed the two-year national obligatory initial postgraduate clinical training programme and then applied to three specialty training programmes - internal medicine, general surgery, and emergency medicine - in a Japanese teaching hospital, where they underwent the Accreditation Council for Graduate Medical Education (ACGME)-competency-based MMI. This MMI contained five stations, with two examiners per station. In each station, a PBQ, and then an SQ were asked consecutively. PBQ and SQ interview formats were not separated into two different stations, or the order of questioning of PBQs and SQs in individual stations was not changed due to lack of space and experienced examiners. Reliability was analysed for the scores of these two MMI question types. Candidates and examiners were surveyed on this experience. The PBQ and SQ formats had generalisability coefficients of 0.822 and 0.821, respectively. With one examiner per station, seven stations could produce a reliability of more than 0.80 in both PBQ and SQ formats. More than 60% of both candidates and examiners felt positive about the overall candidates' ability. All participants liked the fairness of this MMI when compared with the previously experienced SSPI. SQs were perceived more favourable by candidates; in contrast, PBQs were perceived more relevant by examiners. Both PBQs and SQs are equally reliable and acceptable as station interview formats in the postgraduate admissions MMI. However, the use of the two formats within the same station, and with a fixed order, is not the best to maximise its utility as an admission test. Future studies are required to evaluate how best the SQs and PBQs should be combined as station interview formats to enhance reliability, feasibility, acceptability and predictive validity of the MMI.

  2. MMI: Increasing Community Collaboration

    NASA Astrophysics Data System (ADS)

    Galbraith, N. R.; Stocks, K.; Neiswender, C.; Maffei, A.; Bermudez, L.

    2007-12-01

    Building community requires a collaborative environment and guidance to help move members towards a common goal. An effective environment for community collaboration is a workspace that fosters participation and cooperation; effective guidance furthers common understanding and promotes best practices. The Marine Metadata Interoperability (MMI) project has developed a community web site to provide a collaborative environment for scientists, technologists, and data managers from around the world to learn about metadata and exchange ideas. Workshops, demonstration projects, and presentations also provide community-building opportunities for MMI. MMI has developed comprehensive online guides to help users understand and work with metadata standards, ontologies, and other controlled vocabularies. Documents such as "The Importance of Metadata Standards", "Usage vs. Discovery Vocabularies" and "Developing Controlled Vocabularies" guide scientists and data managers through a variety of metadata-related concepts. Members from eight organizations involved in marine science and informatics collaborated on this effort. The MMI web site has moved from Plone to Drupal, two content management systems which provide different opportunities for community-based work. Drupal's "organic groups" feature will be used to provide workspace for future teams tasked with content development, outreach, and other MMI mission-critical work. The new site is designed to enable members to easily create working areas, to build communities dedicated to developing consensus on metadata and other interoperability issues. Controlled-vocabulary-driven menus, integrated mailing-lists, member-based content creation and review tools are facets of the new web site architecture. This move provided the challenge of developing a hierarchical vocabulary to describe the resources presented on the site; consistent and logical tagging of web pages is the basis of Drupal site navigation. The new MMI web site presents enhanced opportunities for electronic discussions, focused collaborative work, and even greater community participation. The MMI project is beginning a new initiative to comprehensively catalog and document tools for marine metadata. The new MMI community-based web site will be used to support this work and to support the work of other ad-hoc teams in the future. We are seeking broad input from the community on this effort.

  3. Medical School Performance of Socioeconomically Disadvantaged and Underrepresented Minority Students Matriculating after a Multiple Mini-Interview.

    PubMed

    Jerant, Anthony; Henderson, Mark C; Griffin, Erin; Talamantes, Efrain; Fancher, Tonya; Sousa, Francis; Franks, Peter

    2018-01-01

    Multiple Mini-Interviews (MMIs) are increasingly used in medical school admissions. We previously reported that while under-represented minority (URM) status was not associated with MMI scores, self-designated disadvantaged applicants had lower MMI scores, possibly affecting their matriculation prospects. No studies have examined how URM status or socioeconomic disadvantage (SED) are associated with academic performance following admission through an MMI. We examined the adjusted associations of MMI scores, SED, and URM status with U.S. Medical Licensing Examination Steps 1 and 2 performance and third-year clerkship Honors, measures affecting residency matching. While URM status was not associated with the measures, students with greater SED had lower Step 1 scores and fewer Honors. Students with higher MMI scores had more Step 1 failures, but more Honors. The findings identify areas to address in medical school admissions, student support, and evaluation processes, which is important given the need for a more representative physician workforce.

  4. Can the multiple mini-interview predict academic achievement in medical school?

    PubMed

    Kim, Ja Kyoung; Kang, Seok Hoon; Lee, Hee Jae; Yang, JeongHee

    2014-09-01

    The purpose of this study was to determine whether the multiple mini-interview (MMI) predicts academic achievement for subjects in a medical school curriculum. Of 49 students who were admitted in 2008, 46 students finished the entire medical education curriculum within 4 years. We calculated the Pearson correlation coefficients between the total MMI score of the 46 graduates and their academic achievements in all subjects of the curriculum. The correlation coefficients between total MMI score and academic achievement in Medical Interview and History Taking, Problem-Based Learning, Doctoring I, and Clinical Practice of Surgery ranged from 0.4 to 0.7, indicating that they were moderately related. The values between total MMI score and achievement in Research Overview, Technical and Procedural Skills, Clinical Performance Examinations 1 and 3, Clinical Practice of Laboratory Medicine and Psychiatry, Neurology, and Orthopedics ranged from 0.2 to 0.4, which meant that they were weakly related. MMI score can predict medical student' academic achievement in subjects in the medical humanities and clinical practice.

  5. Mode/Medium Instability in CO2 Laser

    NASA Technical Reports Server (NTRS)

    Webster, K. L.; Sung, C. C.

    1992-01-01

    Report discribes theoretical study of model/medium instability (MMI) in CO2 laser. Purposes of study to extend, to small Fresnel numbers, previous study of MMI restricted to large Fresnel numbers and to study methods of previous studies, to suppress MMI. Method of primary interest involves replacement of hard edge output mirror in laser resonator with mirror, local reflectivity of which decreases with radial distance from optical axis according to Gaussian profile.

  6. Toxicological considerations for antithyroid drugs in children.

    PubMed

    Karras, Spiros; Tzotzas, Themistoklis; Krassas, Gerasimos E

    2011-04-01

    Propylthiouracil (PTU), methimazole (MMI) and carbimazole are indicated for the treatment of hyperthyroidism in adult and pediatric patients. The aim of this review is to present all the relevant information regarding the use of antithyroid drugs (ATD) in pediatric thyrotoxic cases, the pediatric toxicology of ATD and the warning which has recently been issued for PTU by the FDA. Epidemiology, diagnosis and treatment of pediatric thyrotoxicosis are all presented in this article. The authors also extensively discuss the details regarding the pharmacology, bioactivation, biodisposition, bioavailability and pharmacokinetic properties of the two main ATD (MMI and PTU). The FDA recently reported that use of PTU is associated with a higher risk for clinically serious or fatal liver injury compared to MMI in both adult and pediatric patients. They also found that congenital malformations were reported approximately three times more often with prenatal exposure to MMI compared with PTU and especially with the use of MMI during the first trimester of pregnancy. The authors believe that PTU should not be used in pediatric patients unless the patient is allergic to or intolerant of MMI, and there are no other treatment options available. That being said, PTU may be the treatment of choice during, and just before, the first trimester of pregnancy.

  7. Simulation of the novel compact structure of an interferometric biosensor based on multimode interference waveguides

    NASA Astrophysics Data System (ADS)

    Xhoxhi, Moisi; Dudia, Alma; Ymeti, Aurel

    2017-05-01

    We propose the novel structure of an interferometric biosensor based on multimode interference (MMI) waveguides. We present the design of the biosensor using eigenmode expansion (EME) method in accordance with the requirements and standards of today's photonic technology. The MMI structures with a 90 nm Si3N4 core are used as power splitters with 5 outputs. The 5 high-resolution images at the end of the multimode region show high power balance. We analyze the coupling efficiency of the laser source with the structure, the excess loss and power imbalance for different compact MMI waveguides with widths ranging from 45 μm to 15 μm. For a laser source with a tolerance of +/-1mm in linearization we could achieve a coupling efficiency of 52%. MMI waveguides with tapered channels show excess loss values under 0.5 dB and power imbalance values under 0.08 dB. In addition, we show that for a 10 nm deviation of the source wavelength from its optimal value and for a 10 μm deviation of the MMI length from its optimal value, the performance of the MMI waveguides remains acceptable. Finally, we analyze the power budget of the whole biosensor structure and show that it is sufficient for the proper operation of this device.

  8. Embryonic exposure to propylthiouracil disrupts left-right patterning in Xenopus embryos.

    PubMed

    van Veenendaal, Nicole R; Ulmer, Bärbel; Boskovski, Marko T; Fang, Xiefan; Khokha, Mustafa K; Wendler, Christopher C; Blum, Martin; Rivkees, Scott A

    2013-02-01

    Antithyroid medications are the preferred therapy for the treatment of Graves' disease during pregnancy. Propylthiouracil (PTU) is favored over methimazole (MMI) due to potential teratogenic concerns with MMI. This study was to determine the teratogenic potential of MMI and PTU using a validated Xenopus tropicalis embryo model. Embryos were exposed to 1 mM PTU (EC(50)=0.88 mM), 1 mM MMI, or vehicle control (water) from stages 2 to 45. Treated embryos were examined for gross morphological defects, ciliary function, and gene expression by in situ hybridization. Exposure to PTU, but not MMI, led to cardiac and gut looping defects and shortening along the anterior-posterior axis. PTU exposure during gastrulation (stage 8-12.5) was identified as the critical period of exposure leading to left-right (LR) patterning defects. Abnormal cilia polarization, abnormal cilia-driven leftward flow at the gastrocoel roof plate (GRP), and aberrant expression of both Coco and Pitx2c were associated with abnormal LR symmetry observed following PTU exposure. PTU is teratogenic during late blastula, gastrulation, and neurulation; whereas MMI is not. PTU alters ciliary-driven flow and disrupts the normal genetic program involved in LR axis determination. These studies have important implications for women taking PTU during early pregnancy.

  9. Future Cyborgs: Human-Machine Interface for Virtual Reality Applications

    DTIC Science & Technology

    2007-04-01

    FUTURE CYBORGS : HUMAN-MACHINE INTERFACE FOR VIRTUAL REALITY APPLICATIONS Robert R. Powell, Major, USAF April 2007 Blue Horizons...SUBTITLE Future Cyborgs : Human-Machine Interface for Virtual Reality Applications 5a. CONTRACT NUMBER 5b. GRANT NUMBER 5c. PROGRAM ELEMENT NUMBER...Nicholas Negroponte, Being Digital (New York: Alfred A Knopf, Inc, 1995), 123. 23 Ibid. 24 Andy Clark, Natural-Born Cyborgs (New York: Oxford

  10. Multiple mini-interview as a predictor of performance in the objective structured clinical examination among Physician Associates in the United Kingdom: a cohort study

    PubMed Central

    Kumar, Narendra; Bhardwaj, Shailaja; Rahman, Eqram

    2018-01-01

    Introduction Patient satisfaction and health care outcomes are directly linked to useful communication skills. Therefore, excellent interpersonal skills are imperative for health care professionals. Multiple mini-interview (MMI) is designed as a selection tool to assess the communication skills of applicants in medical schools during the admission process. However, objective structured clinical examination (OSCE) assesses students’ communication and clinical skills at the end of their academic terms. Recently, Anglia Ruskin University, Chelmsford, UK, adopted MMI in the selection process for the first cohort of MSc Physician Associate trainees for the academic year 2015–2016. This study aimed to determine the likelihood of MMI as a predictor of future performance of communication skills in the OSCE. Materials and methods The anonymous data of the average scores of communication skills attained in MMI and OSCE at the end of year 1 were collected for 30 students from the Physician Associate program team. Subsequently, Pearson’s correlation was computed to determine the relationship between the average scores of communication skills attained in MMI, and OSCE during trimester 2 and trimester 3 by the Physician Associate trainees. Results The study showed positive correlation between the scores of communication skills attained in MMI and OSCE during trimester 2 (r=0.956, n=30, p<0.001) and trimester 3 (r=0.966, n=30, p<0.001). Conclusion The study provides empirical evidence for the validity of MMI as a predictor of future performance of Physician Associate trainees’ communication skills during subsequent OSCEs. PMID:29695944

  11. A Multispectral Micro-Imager for Lunar Field Geology

    NASA Technical Reports Server (NTRS)

    Nunez, Jorge; Farmer, Jack; Sellar, Glenn; Allen, Carlton

    2009-01-01

    Field geologists routinely assign rocks to one of three basic petrogenetic categories (igneous, sedimentary or metamorphic) based on microtextural and mineralogical information acquired with a simple magnifying lens. Indeed, such observations often comprise the core of interpretations of geological processes and history. The Multispectral Microscopic Imager (MMI) uses multi-wavelength, light-emitting diodes (LEDs) and a substrate-removed InGaAs focal-plane array to create multispectral, microscale reflectance images of geological samples (FOV 32 X 40 mm). Each pixel (62.5 microns) of an image is comprised of 21 spectral bands that extend from 470 to 1750 nm, enabling the discrimination of a wide variety of rock-forming minerals, especially Fe-bearing phases. MMI images provide crucial context information for in situ robotic analyses using other onboard analytical instruments (e.g. XRD), or for the selection of return samples for analysis in terrestrial labs. To further assess the value of the MMI as a tool for lunar exploration, we used a field-portable, tripod-mounted version of the MMI to image a variety of Apollo samples housed at the Lunar Experiment Laboratory, NASA s Johnson Space Center. MMI images faithfully resolved the microtextural features of samples, while the application of ENVI-based spectral end member mapping methods revealed the distribution of Fe-bearing mineral phases (olivine, pyroxene and magnetite), along with plagioclase feldspars within samples. Samples included a broad range of lithologies and grain sizes. Our MMI-based petrogenetic interpretations compared favorably with thin section-based descriptions published in the Lunar Sample Compendium, revealing the value of MMI images for astronaut and rover-mediated lunar exploration.

  12. Multiple mini-interview as a predictor of performance in the objective structured clinical examination among Physician Associates in the United Kingdom: a cohort study.

    PubMed

    Kumar, Narendra; Bhardwaj, Shailaja; Rahman, Eqram

    2018-01-01

    Patient satisfaction and health care outcomes are directly linked to useful communication skills. Therefore, excellent interpersonal skills are imperative for health care professionals. Multiple mini-interview (MMI) is designed as a selection tool to assess the communication skills of applicants in medical schools during the admission process. However, objective structured clinical examination (OSCE) assesses students' communication and clinical skills at the end of their academic terms. Recently, Anglia Ruskin University, Chelmsford, UK, adopted MMI in the selection process for the first cohort of MSc Physician Associate trainees for the academic year 2015-2016. This study aimed to determine the likelihood of MMI as a predictor of future performance of communication skills in the OSCE. The anonymous data of the average scores of communication skills attained in MMI and OSCE at the end of year 1 were collected for 30 students from the Physician Associate program team. Subsequently, Pearson's correlation was computed to determine the relationship between the average scores of communication skills attained in MMI, and OSCE during trimester 2 and trimester 3 by the Physician Associate trainees. The study showed positive correlation between the scores of communication skills attained in MMI and OSCE during trimester 2 ( r =0.956, n=30, p <0.001) and trimester 3 ( r =0.966, n=30, p <0.001). The study provides empirical evidence for the validity of MMI as a predictor of future performance of Physician Associate trainees' communication skills during subsequent OSCEs.

  13. Should efforts in favor of medical student diversity be focused during admissions or farther upstream?

    PubMed

    Reiter, Harold I; Lockyer, Jocelyn; Ziola, Barry; Courneya, Carol-Ann; Eva, Kevin

    2012-04-01

    Traditional medical school admissions assessment tools may be limiting diversity. This study investigates whether the Multiple Mini-Interview (MMI) is diversity-neutral and, if so, whether applying it with greater weight would dilute the anticipated negative impact of diversity-limiting admissions measures. Interviewed applicants to six medical schools in 2008 and 2009 underwent MMI. Predictor variables of MMI scores, grade point average (GPA), and Medical College Admission Test (MCAT) scores were correlated with diversity measures of age, gender, size of community of origin, income level, and self-declared aboriginal status. A subset of the data was then combined with variable weight assigned to predictor variables to determine whether weighting during the applicant selection process would affect diversity among chosen applicants. MMI scores were unrelated to gender, size of community of origin, and income level. They correlated positively with age and negatively with aboriginal status. GPA and MCAT correlated negatively with age and aboriginal status, GPA correlated positively with income level, and MCAT correlated positively with size of community of origin. Even extreme combinations of MMI and GPA weightings failed to increase diversity among applicants who would be selected on the basis of weighted criteria. MMI could not neutralize the diversity-limiting properties of academic scores as selection criteria to interview. Using academic scores in this way causes range restriction, counteracting attempts to enhance diversity using downstream admissions selection measures such as MMI. Diversity efforts should instead be focused upstream. These results lend further support for the development of pipeline programs.

  14. Advanced analysis of forest fire clustering

    NASA Astrophysics Data System (ADS)

    Kanevski, Mikhail; Pereira, Mario; Golay, Jean

    2017-04-01

    Analysis of point pattern clustering is an important topic in spatial statistics and for many applications: biodiversity, epidemiology, natural hazards, geomarketing, etc. There are several fundamental approaches used to quantify spatial data clustering using topological, statistical and fractal measures. In the present research, the recently introduced multi-point Morisita index (mMI) is applied to study the spatial clustering of forest fires in Portugal. The data set consists of more than 30000 fire events covering the time period from 1975 to 2013. The distribution of forest fires is very complex and highly variable in space. mMI is a multi-point extension of the classical two-point Morisita index. In essence, mMI is estimated by covering the region under study by a grid and by computing how many times more likely it is that m points selected at random will be from the same grid cell than it would be in the case of a complete random Poisson process. By changing the number of grid cells (size of the grid cells), mMI characterizes the scaling properties of spatial clustering. From mMI, the data intrinsic dimension (fractal dimension) of the point distribution can be estimated as well. In this study, the mMI of forest fires is compared with the mMI of random patterns (RPs) generated within the validity domain defined as the forest area of Portugal. It turns out that the forest fires are highly clustered inside the validity domain in comparison with the RPs. Moreover, they demonstrate different scaling properties at different spatial scales. The results obtained from the mMI analysis are also compared with those of fractal measures of clustering - box counting and sand box counting approaches. REFERENCES Golay J., Kanevski M., Vega Orozco C., Leuenberger M., 2014: The multipoint Morisita index for the analysis of spatial patterns. Physica A, 406, 191-202. Golay J., Kanevski M. 2015: A new estimator of intrinsic dimension based on the multipoint Morisita index. Pattern Recognition, 48, 4070-4081.

  15. Candidate Evaluation Using Targeted Construct Assessment in the Multiple Mini-Interview: A Multifaceted Rasch Model Analysis.

    PubMed

    McLaughlin, Jacqueline E; Singer, David; Cox, Wendy C

    2017-01-01

    Construct: A 7-station multiple mini-interview (MMI) circuit was implemented and assessed for 214 candidates rated by 37 interviewers (N = 1,498 ratings). The MMI stations were designed to assess 6 specific constructs (adaptability, empathy, integrity, critical thinking, teamwork [receiving instruction], teamwork [giving instruction]) and one open station about the candidate's interest in the school. Despite the apparent benefits of the MMI, construct-irrelevant variance continues to be a topic of study. Refining the MMI to more effectively measure candidate ability is critical to improving our ability to identify and select candidates that are equipped for success within health professions education and the workforce. Each station assessed a single construct and was rated by a single interviewer who was provided only the name of the candidate and no additional information about the candidate's background, application, or prior academic performance. All interviewers received online and in-person training in the fall prior to the MMI and the morning of the MMI. A 3-facet multifaceted Rasch measurement analysis was completed to determine interviewer severity, candidate ability, and MMI station difficulty and examine how the model performed overall (e.g., rating scale). Altogether, the Rasch measures explained 62.84% of the variance in the ratings. Differences in candidate ability explained 45.28% of the variance in the data, whereas differences in interviewer severity explained 16.09% of the variance in the data. None of the interviewers had Infit or Outfit mean-square scores greater than 1.7, and only 2 (5.4%) had mean-square scores less than 0.5. The data demonstrated acceptable fit to the multifaceted Rasch measurement model. This work is the first of its kind in pharmacy and provides insight into the development of an MMI that provides useful and meaningful candidate assessment ratings for institutional decision making.

  16. Low muscle mass and risk of type 2 diabetes in middle-aged and older adults: findings from the KoGES.

    PubMed

    Son, Jang Won; Lee, Seong Su; Kim, Sung Rae; Yoo, Soon Jib; Cha, Bong Yun; Son, Ho Young; Cho, Nam H

    2017-05-01

    Asians have a propensity to develop type 2 diabetes with a lower BMI than Western populations. This discrepancy may be due to differences in body fat and muscle mass for a given BMI. However, unlike adiposity, it is unclear whether muscle mass affects the risk of type 2 diabetes in Asian populations. We conducted a 2-yearly prospective assessment of 6895 participants who were free of diabetes at the baseline examination as part of the Korean Genome Epidemiology Study. The muscle mass index (MMI) was defined as the weight-adjusted appendicular skeletal muscle mass. Using Cox regression models, we evaluated the association between MMI and the risk of developing type 2 diabetes across sex-specific tertiles of MMI. Low muscle mass was defined as the sex-specific lowest tertile of MMI. Main covariates included age, sex, urban or rural residence, family history of diabetes, hypertension, smoking status, education level, monthly income, physical activity, alcohol consumption and diet. In addition, body fat mass, waist circumference and BMI were controlled as categorical variables. Obesity was defined as a BMI of ≥25 kg/m 2 or a waist circumference of ≥90 cm for men and ≥85 cm for women. During a median follow-up of 9.06 years, 1336 participants developed type 2 diabetes. At baseline, the mean age was 52.1 years and the mean BMI was 24.4 kg/m 2 . The mean MMI for men and women was 32.1% and 26.0%, respectively. There was an inverse association between MMI and the risk of type 2 diabetes. Multivariate-adjusted HRs for the risk of developing type 2 diabetes were 2.05 (95% CI 1.73, 2.43), 1.39 (95% CI 1.17, 1.66) and 1.0 from the lowest to highest sex-specific MMI tertile, with an HR of 1.35 (95% CI 1.26, 1.45) per SD decline in MMI. Further adjustments for fat mass, waist circumference and BMI as categorical variables did not modify the relationship (each p < 0.01). In BMI-stratified analyses, the population-attributable fraction of the lowest tertile of MMI for developing type 2 diabetes was increased by 11.9% in the non-obese group and 19.7% in the obese group. Low muscle mass as defined by MMI was associated with an increased risk of type 2 diabetes, independent of general obesity, in middle-aged and older Korean adults.

  17. A passively mode locked thulium doped fiber laser using bismuth telluride deposited multimode interference

    NASA Astrophysics Data System (ADS)

    Jung, M.; Lee, J.; Song, W.; Lee, Y. L.; Lee, J. H.; Shin, W.

    2016-05-01

    We proposed a multimode interference (MMI) fiber based saturable absorber using bismuth telluride at  ∼2 μm region. Our MMI based saturable absorber was fabricated by fusion splicing with single mode fiber and null core fiber. The MMI functioned as both wavelength fixed filter and saturable absorber. The 3 dB bandwidth and insertion loss of MMI were 42 nm and 3.4 dB at wavelength of 1958 nm, respectively. We have also reported a passively mode locked thulium doped fiber laser operating at a wavelength of 1958 nm using a multimode interference. A temporal bandwidth of  ∼46 ps was experimentally obtained at a repetition rate of 8.58 MHz.

  18. An optical mm-wave generation scheme by frequency octupling using a nested MMI

    NASA Astrophysics Data System (ADS)

    Shang, Lei; Wen, Aijun; Li, Bo; Wang, Tonggang; Chen, Yang; Li, Ming'an

    2011-12-01

    A novel method of a filterless optical millimeter-wave (MMW) signal generation with frequency octupling via a nested multimode interference (MMI) coupler is proposed for Radio-over-fiber systems. By setting the DC bias voltage applied to the central arms of MMI-b and MMI-c accurately, the optical carrier can be completely suppressed. The OSSR can be as high as about 58 dB without optical filter and the radio frequency spurious suppression ratio (RFSSR) exceeds 32 dB, which is the best result as we know. Simulation results suggest that when the generated optical mm-wave signal is transmitted along the standard single-mode fiber, the eye diagram is still opened after being transmitted over a 50 km fiber.

  19. Multispectral Microscopic Imager (MMI): Multispectral Imaging of Geological Materials at a Handlens Scale

    NASA Astrophysics Data System (ADS)

    Farmer, J. D.; Nunez, J. I.; Sellar, R. G.; Gardner, P. B.; Manatt, K. S.; Dingizian, A.; Dudik, M. J.; McDonnell, G.; Le, T.; Thomas, J. A.; Chu, K.

    2011-12-01

    The Multispectral Microscopic Imager (MMI) is a prototype instrument presently under development for future astrobiological missions to Mars. The MMI is designed to be a arm-mounted rover instrument for use in characterizing the microtexture and mineralogy of materials along geological traverses [1,2,3]. Such geological information is regarded as essential for interpreting petrogenesis and geological history, and when acquired in near real-time, can support hypothesis-driven exploration and optimize science return. Correlated microtexure and mineralogy also provides essential data for selecting samples for analysis with onboard lab instruments, and for prioritizing samples for potential Earth return. The MMI design employs multispectral light-emitting diodes (LEDs) and an uncooled focal plane array to achieve the low-mass (<1kg), low-cost, and high reliability (no moving parts) required for an arm-mounted instrument on a planetary rover [2,3]. The MMI acquires multispectral, reflectance images at 62 μm/pixel, in which each image pixel is comprised of a 21-band VNIR spectrum (0.46 to 1.73 μm). This capability enables the MMI to discriminate and resolve the spatial distribution of minerals and textures at the microscale [2, 3]. By extending the spectral range into the infrared, and increasing the number of spectral bands, the MMI exceeds the capabilities of current microimagers, including the MER Microscopic Imager (MI); 4, the Phoenix mission Robotic Arm Camera (RAC; 5) and the Mars Science Laboratory's Mars Hand Lens Imager (MAHLI; 6). In this report we will review the capabilities of the MMI by highlighting recent lab and field applications, including: 1) glove box deployments in the Astromaterials lab at Johnson Space Center to analyze Apollo lunar samples; 2) GeoLab glove box deployments during the 2011 Desert RATS field trials in northern AZ to characterize analog materials collected by astronauts during simulated EVAs; 3) field deployments on Mauna Kea Volcano, Hawaii, during NASA's 2010 ISRU field trials, to analyze materials at the primary feedstock mining site; 4) lab characterization of geological samples from a complex, volcanic-hydrothermal terrain in the Cady Mts., SE Mojave Desert, California. We will show how field and laboratory applications have helped drive the development and refinement of MMI capabilities, while identifying synergies with other potential payload instruments (e.g. X-ray Diffraction) for solving real geological problems.

  20. Reliability and acceptability of six station multiple mini-interviews: past-behavioural versus situational questions in postgraduate medical admission.

    PubMed

    Yamada, Toru; Sato, Juichi; Yoshimura, Hiroshi; Okubo, Tomoya; Hiraoka, Eiji; Shiga, Takashi; Kubota, Tadao; Fujitani, Shigeki; Machi, Junji; Ban, Nobutaro

    2017-03-16

    The multiple mini-interview (MMI) is increasingly used for postgraduate medical admissions and in undergraduate settings. MMIs use mostly Situational Questions (SQs) rather than Past-Behavioural Questions (PBQs). A previous study of MMIs in this setting, where PBQs and SQs were asked in the same order, reported that the reliability of PBQs was non-inferior to SQs and that SQs were more acceptable to candidates. The order in which the questions are asked may affect reliability and acceptability of an MMI. This study investigated the reliability of an MMI using both PBQs and SQs, minimising question order bias. Acceptability of PBQs and SQs was also assessed. Forty candidates applying for a postgraduate medical admission for 2016-2017 were included; 24 examiners were used. The MMI consisted of six stations with one examiner per station; a PBQ and a SQ were asked at every station, and the order of questions was alternated between stations. Reliability was analysed for scores obtained for PBQs or SQs separately, and for both questions. A post-MMI survey was used to assess the acceptability of PBQs and SQs. The generalisability (G) coefficients for PBQs only, SQs only, and both questions were 0.87, 0.96, and 0.80, respectively. Decision studies suggested that a four-station MMI would also be sufficiently reliable (G-coefficients 0.82 and 0.94 for PBQs and SQs, respectively). In total, 83% of participants were satisfied with the MMI. In terms of face validity, PBQs were more acceptable than SQs for candidates (p = 0.01), but equally acceptable for examiners (88% vs. 83% positive responses for PBQs vs. SQs; p = 0.377). Candidates preferred PBQs to SQs when asked to choose one, though this difference was not significant (p = 0.081); examiners showed a clear preference for PBQs (p = 0.007). Reliability and acceptability of six-station MMI were good among 40 postgraduate candidates; modelling suggested that four stations would also be reliable. SQs were more reliable than PBQs. Candidates found PBQs more acceptable than SQs and examiners preferred PBQs when they had to choose between the two. Our findings suggest that it is better to ask both PBQs and SQs during an MMI to maximise acceptability.

  1. Effect of antithyroid drug on chick embryos during the last week of development: delayed hatching and decreased cerebellar acetylcholinesterase activity.

    PubMed

    Haba, Gen; Nishigori, Hidekazu; Tezuka, Yu; Kagami, Keisuke; Sugiyama, Toru; Nishigori, Hideo

    2011-11-01

    Hypothyroid state during embryogenesis disturbs normal growth and brain development, influencing later life. To evaluate the harmful consequences of the state during embryogenesis using an animal model, we inhibited thyroid hormone biosynthesis in chick embryos by using methimazole (MMI). Typically, embryos were treated with MMI (20 µmol/egg) on day 14, and examined on specific days.  Of the control embryos, 94% hatched on day 21, whereas 0% and 60% of MMI-treated embryos hatched on days 21 and 24, respectively. MMI retarded the rates of bodyweight gain as well as liver and heart development, and delayed hatching. However, the external differences in appearance and differences in the weights of the newly hatched control chicks on day 21 and the MMI-treated chicks on day 24 were less obvious. Embryos treated with MMI exhibited increased mass in their brain parts on day 24. Most notably, the treatment resulted in a 1.35-fold increase in cerebellum weight compared to that of the untreated animals. Acetylcholinesterase activity in the cerebellum on the day of hatching decreased significantly to 0.85-fold that of the untreated controls. Thyroid hormone receptor β mRNA was detected from day 12 and dramatically expressed from day 19 to the day of hatching. The 'fertilized hen's egg-chick embryo-chick system' is an appropriate animal model for investigating the hypothyroid state during embryogenesis. Decreased cerebellar acetylcholinesterase activity after MMI treatment was assumed to relate to a mechanism of motor and cognitive deficits in congenital hypothyroidism. © 2011 The Authors. Journal of Obstetrics and Gynaecology Research © 2011 Japan Society of Obstetrics and Gynecology.

  2. Science applications of a multispectral microscopic imager for the astrobiological exploration of Mars

    USGS Publications Warehouse

    Nunez, Jorge; Farmer, Jack; Sellar, R. Glenn; Swayze, Gregg A.; Blaney, Diana L.

    2014-01-01

    Future astrobiological missions to Mars are likely to emphasize the use of rovers with in situ petrologic capabilities for selecting the best samples at a site for in situ analysis with onboard lab instruments or for caching for potential return to Earth. Such observations are central to an understanding of the potential for past habitable conditions at a site and for identifying samples most likely to harbor fossil biosignatures. The Multispectral Microscopic Imager (MMI) provides multispectral reflectance images of geological samples at the microscale, where each image pixel is composed of a visible/shortwave infrared spectrum ranging from 0.46 to 1.73 μm. This spectral range enables the discrimination of a wide variety of rock-forming minerals, especially Fe-bearing phases, and the detection of hydrated minerals. The MMI advances beyond the capabilities of current microimagers on Mars by extending the spectral range into the infrared and increasing the number of spectral bands. The design employs multispectral light-emitting diodes and an uncooled indium gallium arsenide focal plane array to achieve a very low mass and high reliability. To better understand and demonstrate the capabilities of the MMI for future surface missions to Mars, we analyzed samples from Mars-relevant analog environments with the MMI. Results indicate that the MMI images faithfully resolve the fine-scale microtextural features of samples and provide important information to help constrain mineral composition. The use of spectral endmember mapping reveals the distribution of Fe-bearing minerals (including silicates and oxides) with high fidelity, along with the presence of hydrated minerals. MMI-based petrogenetic interpretations compare favorably with laboratory-based analyses, revealing the value of the MMI for future in situ rover-mediated astrobiological exploration of Mars.

  3. Science applications of a multispectral microscopic imager for the astrobiological exploration of Mars.

    PubMed

    Núñez, Jorge I; Farmer, Jack D; Sellar, R Glenn; Swayze, Gregg A; Blaney, Diana L

    2014-02-01

    Future astrobiological missions to Mars are likely to emphasize the use of rovers with in situ petrologic capabilities for selecting the best samples at a site for in situ analysis with onboard lab instruments or for caching for potential return to Earth. Such observations are central to an understanding of the potential for past habitable conditions at a site and for identifying samples most likely to harbor fossil biosignatures. The Multispectral Microscopic Imager (MMI) provides multispectral reflectance images of geological samples at the microscale, where each image pixel is composed of a visible/shortwave infrared spectrum ranging from 0.46 to 1.73 μm. This spectral range enables the discrimination of a wide variety of rock-forming minerals, especially Fe-bearing phases, and the detection of hydrated minerals. The MMI advances beyond the capabilities of current microimagers on Mars by extending the spectral range into the infrared and increasing the number of spectral bands. The design employs multispectral light-emitting diodes and an uncooled indium gallium arsenide focal plane array to achieve a very low mass and high reliability. To better understand and demonstrate the capabilities of the MMI for future surface missions to Mars, we analyzed samples from Mars-relevant analog environments with the MMI. Results indicate that the MMI images faithfully resolve the fine-scale microtextural features of samples and provide important information to help constrain mineral composition. The use of spectral endmember mapping reveals the distribution of Fe-bearing minerals (including silicates and oxides) with high fidelity, along with the presence of hydrated minerals. MMI-based petrogenetic interpretations compare favorably with laboratory-based analyses, revealing the value of the MMI for future in situ rover-mediated astrobiological exploration of Mars. Mars-Microscopic imager-Multispectral imaging-Spectroscopy-Habitability-Arm instrument.

  4. Intelligent man/machine interfaces on the space station

    NASA Technical Reports Server (NTRS)

    Daughtrey, Rodney S.

    1987-01-01

    Some important topics in the development of good, intelligent, usable man/machine interfaces for the Space Station are discussed. These computer interfaces should adhere strictly to three concepts or doctrines: generality, simplicity, and elegance. The motivation for natural language interfaces and their use and value on the Space Station, both now and in the future, are discussed.

  5. Should total hip arthroplasty femoral components be designed to subside? A radiostereometric analysis study of the Charnley Elite and Exeter stems.

    PubMed

    Alfaro-Adrián, J; Gill, H S; Murray, D W

    2001-08-01

    The Charnley Elite and the Exeter stems have different design concepts: The former is designed not to subside, whereas the latter is expected to subside. This radiostereometric analysis study compares the early migration of the 2 stems. For both implants, the 1st year migration was about 4 times faster than the 2nd year. The Exeter migration was predominantly distal (1 mm/y in the 1st year). It also showed slight collapse into valgus, and the head migrated slowly posteriorly (0.3 mm/y in the 1st year). In contrast, the Elite had slow distal migration (0.2 mm/y in the 1st year) and rapid posterior head migration (0.8 mm/y in the 1st year). Four Elites and no Exeters had rapid posterior head migration rates (mean 2.8 mm/y in the 1st year and 0.8 mm/y in the 2nd year). The Elite and the Exeter stems have fundamentally different early patterns of migration, which affect their long-term function; 20% of the Elites and none of the Exeters had rapid posterior head migration in the 1st year and the 2nd year and are likely to fail early. Polished, collarless, tapered designs, such as the Exeter, may be more forgiving than conventional stems designed not to subside.

  6. Can Multiple Mini-Interviews Predict Academic Performance of Dental Students? A Two-Year Follow-Up.

    PubMed

    Alaki, Sumer M; Yamany, Ibrahim A; Shinawi, Lana A; Hassan, Mona H A; Tekian, Ara

    2016-11-01

    Prior research has shown that students' previous grade point average (GPA) is the best predictor for future academic success. However, it can only partly predict the variability in dental school performance. The aim of this study was to assess the predictive value of multiple mini-interviews (MMI) as an admission criterion by comparing them with the academic performance of dental students over a two-year period. All incoming undergraduate dental students at the King Abdulaziz University Faculty of Dentistry (KAUFD) during academic year 2013-14 were invited to participate in MMI. Students rotated through six objective structured clinical exam (OSCE)-like stations for 30 minutes total and were interviewed by two trained faculty interviewers at each station. The stations were focused on noncognitive skills thought to be essential to academic performance at KAUFD. The academic performance of these students was then followed for two years and linked to their MMI scores. A total of 146 students (71 males and 75 females) participated in an interview (response rate=92.9%). Most students scored in the acceptable range at each MMI station. Students' total MMI score, ambitions, and motives were significant predictors of GPA during the two years of follow-up (p<0.038 and p<0.001, respectively). In this study, MMI was found to be able to predict future academic performance of undergraduate dental students.

  7. Task-Oriented, Naturally Elicited Speech (TONE) Database for the Force Requirements Expert System, Hawaii (FRESH)

    DTIC Science & Technology

    1988-09-01

    Group Subgroup Command and control; Computational linguistics; expert system voice recognition; man- machine interface; U.S. Government 19 Abstract...simulates the characteristics of FRESH on a smaller scale. This study assisted NOSC in developing a voice-recognition, man- machine interface that could...scale. This study assisted NOSC in developing a voice-recogni- tion, man- machine interface that could be used with TONE and upgraded at a later date

  8. Remission of insulin autoimmune syndrome in a patient with Grave's disease by treatment with methimazole.

    PubMed

    Okabe, R; Inaba, M; Hosoi, M; Ishimura, E; Kumeda, Y; Nishizawa, Y; Morii, H

    1999-06-01

    The patient, a 24-year-old man, had suffered from hunger, sweating, tachycardia and palpitation for three years. He was diagnosed as having Graves' disease (GD) and treated with methimazole (MMI) for 3 months. He noted that palpitation and perspiration seemed to particularly occur when he was hungry, and thus he was examined to determine whether these symptoms were caused by hypoglycemia. As a markedly elevated immunoreactive insulin level and the presence of insulin antibody in serum were found, he was diagnosed as having insulin autoimmune syndrome (IAS). HLA typing revealed the patient to be positive for group Bw62/Cw4/DR4, which is reportedly a specific HLA type in MMI-treated euthyoroid GD patients with IAS. In spite of the continuation of MMI treatment, the % binding of IRI decreased and the hypoglycemic episode disappeared. In contrast to the previously reported MMI induced IAS in GD cases, MMI is unlikely to have exacerbated IAS in the present case, although his HLA combination is identical to that of the previous cases.

  9. Proposal for fabrication-tolerant SOI polarization splitter-rotator based on cascaded MMI couplers and an assisted bi-level taper

    PubMed Central

    Wang, Jing; Qi, Minghao; Xuan, Yi; Huang, Haiyang; Li, You; Li, Ming; Chen, Xin; Jia, Qi; Sheng, Zhen; Wu, Aimin; Li, Wei; Wang, Xi; Zou, Shichang; Gan, Fuwan

    2014-01-01

    A novel silicon-on-insulator (SOI) polarization splitter-rotator (PSR) with a large fabrication tolerance is proposed based on cascaded multimode interference (MMI) couplers and an assisted mode-evolution taper. The tapers are designed to adiabatically convert the input TM0 mode into the TE1 mode, which will output as the TE0 mode after processed by the subsequent MMI mode converter, 90-degree phase shifter (PS) and MMI 3 dB coupler. The numerical simulation results show that the proposed device has a < 0.5 dB insertion loss with < −17 dB crosstalk in C optical communication band. Fabrication tolerance analysis is also performed with respect to the deviations of MMI coupler width, PS width, slab height and upper-cladding refractive index, showing that this device could work well even when affected by considerable fabrication errors. With such a robust performance with a large bandwidth, this device offers potential applications for CMOS-compatible polarization diversity, especially in the booming 100 Gb/s coherent optical communications based on silicon photonics technology. PMID:25402029

  10. Proposal for fabrication-tolerant SOI polarization splitter-rotator based on cascaded MMI couplers and an assisted bi-level taper.

    PubMed

    Wang, Jing; Qi, Minghao; Xuan, Yi; Huang, Haiyang; Li, You; Li, Ming; Chen, Xin; Jia, Qi; Sheng, Zhen; Wu, Aimin; Li, Wei; Wang, Xi; Zou, Shichang; Gan, Fuwan

    2014-11-17

    A novel silicon-on-insulator (SOI) polarization splitter-rotator (PSR) with a large fabrication tolerance is proposed based on cascaded multimode interference (MMI) couplers and an assisted mode-evolution taper. The tapers are designed to adiabatically convert the input TM(0) mode into the TE(1) mode, which will output as the TE(0) mode after processed by the subsequent MMI mode converter, 90-degree phase shifter (PS) and MMI 3 dB coupler. The numerical simulation results show that the proposed device has a < 0.5 dB insertion loss with < -17 dB crosstalk in C optical communication band. Fabrication tolerance analysis is also performed with respect to the deviations of MMI coupler width, PS width, slab height and upper-cladding refractive index, showing that this device could work well even when affected by considerable fabrication errors. With such a robust performance with a large bandwidth, this device offers potential applications for CMOS-compatible polarization diversity, especially in the booming 100 Gb/s coherent optical communications based on silicon photonics technology.

  11. Comparison of automatic traps to capture mosquitoes (Diptera: Culicidae) in rural areas in the tropical Atlantic rainforest

    PubMed Central

    de Sá, Ivy Luizi Rodrigues; Sallum, Maria Anice Mureb

    2013-01-01

    In several countries, surveillance of insect vectors is accomplished with automatic traps. This study addressed the performance of Mosquito Magnet® Independence (MMI) in comparison with those of CDC with CO2 and lactic acid (CDC-A) and CDC light trap (CDC-LT). The collection sites were in a rural region located in a fragment of secondary tropical Atlantic rainforest, southeastern Brazil. Limatus durhami and Limatus flavisetosus were the dominant species in the MMI, whereas Ochlerotatus scapularis was most abundant in CDC-A. Culex ribeirensis and Culex sacchettae were dominant species in the CDC-LT. Comparisons among traps were based on diversity indices. Results from the diversity analyses showed that the MMI captured a higher abundance of mosquitoes and that the species richness estimated with it was higher than with CDC-LT. Contrasting, difference between MMI and CDC-A was not statistically significant. Consequently, the latter trap seems to be both an alternative for the MMI and complementary to it for ecological studies and entomological surveillance. PMID:24402154

  12. Semiconductor laser using multimode interference principle

    NASA Astrophysics Data System (ADS)

    Gong, Zisu; Yin, Rui; Ji, Wei; Wu, Chonghao

    2018-01-01

    Multimode interference (MMI) structure is introduced in semiconductor laser used in optical communication system to realize higher power and better temperature tolerance. Using beam propagation method (BPM), Multimode interference laser diode (MMI-LD) is designed and fabricated in InGaAsP/InP based material. As a comparison, conventional semiconductor laser using straight single-mode waveguide is also fabricated in the same wafer. With a low injection current (about 230 mA), the output power of the implemented MMI-LD is up to 2.296 mW which is about four times higher than the output power of the conventional semiconductor laser. The implemented MMI-LD exhibits stable output operating at the wavelength of 1.52 μm and better temperature tolerance when the temperature varies from 283.15 K to 293.15 K.

  13. The modeling of MMI structures for signal processing applications

    NASA Astrophysics Data System (ADS)

    Le, Thanh Trung; Cahill, Laurence W.

    2008-02-01

    Microring resonators are promising candidates for photonic signal processing applications. However, almost all resonators that have been reported so far use directional couplers or 2×2 multimode interference (MMI) couplers as the coupling element between the ring and the bus waveguides. In this paper, instead of using 2×2 couplers, novel structures for microring resonators based on 3×3 MMI couplers are proposed. The characteristics of the device are derived using the modal propagation method. The device parameters are optimized by using numerical methods. Optical switches and filters using Silicon on Insulator (SOI) then have been designed and analyzed. This device can become a new basic component for further applications in optical signal processing. The paper concludes with some further examples of photonic signal processing circuits based on MMI couplers.

  14. Sharing Human-Generated Observations by Integrating HMI and the Semantic Sensor Web

    PubMed Central

    Sigüenza, Álvaro; Díaz-Pardo, David; Bernat, Jesús; Vancea, Vasile; Blanco, José Luis; Conejero, David; Gómez, Luis Hernández

    2012-01-01

    Current “Internet of Things” concepts point to a future where connected objects gather meaningful information about their environment and share it with other objects and people. In particular, objects embedding Human Machine Interaction (HMI), such as mobile devices and, increasingly, connected vehicles, home appliances, urban interactive infrastructures, etc., may not only be conceived as sources of sensor information, but, through interaction with their users, they can also produce highly valuable context-aware human-generated observations. We believe that the great promise offered by combining and sharing all of the different sources of information available can be realized through the integration of HMI and Semantic Sensor Web technologies. This paper presents a technological framework that harmonizes two of the most influential HMI and Sensor Web initiatives: the W3C's Multimodal Architecture and Interfaces (MMI) and the Open Geospatial Consortium (OGC) Sensor Web Enablement (SWE) with its semantic extension, respectively. Although the proposed framework is general enough to be applied in a variety of connected objects integrating HMI, a particular development is presented for a connected car scenario where drivers' observations about the traffic or their environment are shared across the Semantic Sensor Web. For implementation and evaluation purposes an on-board OSGi (Open Services Gateway Initiative) architecture was built, integrating several available HMI, Sensor Web and Semantic Web technologies. A technical performance test and a conceptual validation of the scenario with potential users are reported, with results suggesting the approach is sound. PMID:22778643

  15. Habitability Concept Models for Living in Space

    NASA Astrophysics Data System (ADS)

    Ferrino, M.

    2002-01-01

    As growing trends show, living in "space" has acquired new meanings, especially considering the utilization of the International Space Station (ISS) with regard to group interaction as well as individual needs in terms of time, space and crew accommodations. In fact, for the crew, the Spaced Station is a combined Laboratory-Office/Home and embodies ethical, social, and cultural aspects as additional parameters to be assessed to achieve a user centered architectural design of crew workspace. Habitability Concept Models can improve the methods and techniques used to support the interior design and layout of space architectures and at the same time guarantee a human focused approach. This paper discusses and illustrates some of the results obtained for the interior design of a Habitation Module for the ISS. In this work, two different but complementary approaches are followed. The first is "object oriented" and based on Video Data (American and Russian) supported by Proxemic methods (Edward T. Hall, 1963 and Francesca Pregnolato, 1998). This approach offers flexible and adaptive design solutions. The second is "subject oriented" and based on a Virtual Reality environment. With this approach human perception and cognitive aspects related to a specific crew task are considered. Data obtained from these two approaches are used to verify requirements and advance the design of the Habitation Module for aspects related to man machine interfaces (MMI), ergonomics, work and free-time. It is expected that the results achieved can be applied to future space related projects.

  16. Sharing human-generated observations by integrating HMI and the Semantic Sensor Web.

    PubMed

    Sigüenza, Alvaro; Díaz-Pardo, David; Bernat, Jesús; Vancea, Vasile; Blanco, José Luis; Conejero, David; Gómez, Luis Hernández

    2012-01-01

    Current "Internet of Things" concepts point to a future where connected objects gather meaningful information about their environment and share it with other objects and people. In particular, objects embedding Human Machine Interaction (HMI), such as mobile devices and, increasingly, connected vehicles, home appliances, urban interactive infrastructures, etc., may not only be conceived as sources of sensor information, but, through interaction with their users, they can also produce highly valuable context-aware human-generated observations. We believe that the great promise offered by combining and sharing all of the different sources of information available can be realized through the integration of HMI and Semantic Sensor Web technologies. This paper presents a technological framework that harmonizes two of the most influential HMI and Sensor Web initiatives: the W3C's Multimodal Architecture and Interfaces (MMI) and the Open Geospatial Consortium (OGC) Sensor Web Enablement (SWE) with its semantic extension, respectively. Although the proposed framework is general enough to be applied in a variety of connected objects integrating HMI, a particular development is presented for a connected car scenario where drivers' observations about the traffic or their environment are shared across the Semantic Sensor Web. For implementation and evaluation purposes an on-board OSGi (Open Services Gateway Initiative) architecture was built, integrating several available HMI, Sensor Web and Semantic Web technologies. A technical performance test and a conceptual validation of the scenario with potential users are reported, with results suggesting the approach is sound.

  17. Learning Machine, Vietnamese Based Human-Computer Interface.

    ERIC Educational Resources Information Center

    Northwest Regional Educational Lab., Portland, OR.

    The sixth session of IT@EDU98 consisted of seven papers on the topic of the learning machine--Vietnamese based human-computer interface, and was chaired by Phan Viet Hoang (Informatics College, Singapore). "Knowledge Based Approach for English Vietnamese Machine Translation" (Hoang Kiem, Dinh Dien) presents the knowledge base approach,…

  18. Nanoscale wear and machining behavior of nanolayer interfaces.

    PubMed

    Nie, Xueyuan; Zhang, Peng; Weiner, Anita M; Cheng, Yang-Tse

    2005-10-01

    An atomic force microscope was used to subnanometer incise a nanomultilayer to consequently expose individual nanolayers and interfaces on which sliding and scanning nanowear/machining have been performed. The letter reports the first observation on the nanoscale where (i) atomic debris forms in a collective manner, most-likely by deformation and rupture of atomic bonds, and (ii) the nanolayer interfaces possess a much higher wear resistance (desired for nanomachines) or lower machinability (not desired for nanomachining) than the layers.

  19. Best face forward.

    PubMed

    Rayport, Jeffrey F; Jaworski, Bernard J

    2004-12-01

    Most companies serve customers through a broad array of interfaces, from retail sales clerks to Web sites to voice-response telephone systems. But while the typical company has an impressive interface collection, it doesn't have an interface system. That is, the whole set does not add up to the sum of its parts in its ability to provide service and build customer relationships. Too many people and too many machines operating with insufficient coordination (and often at cross-purposes) mean rising complexity, costs, and customer dissatisfaction. In a world where companies compete not on what they sell but on how they sell it, turning that liability into an asset is what separates winners from losers. In this adaptation of their forthcoming book by the same title, Jeffrey Rayport and Bernard Jaworski explain how companies must reengineer their customer interface systems for optimal efficiency and effectiveness. Part of that transformation, they observe, will involve a steady encroachment by machine interfaces into areas that have long been the sacred province of humans. Managers now have opportunities unprecedented in the history of business to use machines, not just people, to credibly manage their interactions with customers. Because people and machines each have their strengths and weaknesses, company executives must identify what people do best, what machines do best, and how to deploy them separately and together. Front-office reengineering subjects every current and potential service interface to an analysis of opportunities for substitution (using machines instead of people), complementarity (using a mix of machines and people), and displacement (using networks to shift physical locations of people and machines), with the twin objectives of compressing costs and driving top-line growth through increased customer value.

  20. Multiple man-machine interfaces

    NASA Technical Reports Server (NTRS)

    Stanton, L.; Cook, C. W.

    1981-01-01

    The multiple man machine interfaces inherent in military pilot training, their social implications, and the issue of possible negative feedback were explored. Modern technology has produced machines which can see, hear, and touch with greater accuracy and precision than human beings. Consequently, the military pilot is more a systems manager, often doing battle against a target he never sees. It is concluded that unquantifiable human activity requires motivation that is not intrinsic in a machine.

  1. Ultracompact photonic crystal polarization beam splitter based on multimode interference.

    PubMed

    Lu, Ming-Feng; Liao, Shan-Mei; Huang, Yang-Tung

    2010-02-01

    We propose a theoretical design for a compact photonic crystal (PC) polarization beam splitter (PBS) based on the multimode interference (MMI) effect. The size of a conventional MMI device designed by the self-imaging principle is not compact enough; therefore, we design a compact PC PBS based on the difference of the interference effect between TE and TM modes. Within the MMI coupler, the dependence of interference of modes on propagation distance is weak for a TE wave and strong for a TM wave; as a result, the length of the MMI section can be only seven lattice constants. Simulation results show that the insertion losses are 0.32 and 0.89 dB, and the extinction ratios are 14.4 and 17.5 dB for Port 1 (TE mode) and Port 2 (TM mode), respectively.

  2. Multimode quantum interference of photons in multiport integrated devices

    PubMed Central

    Peruzzo, Alberto; Laing, Anthony; Politi, Alberto; Rudolph, Terry; O'Brien, Jeremy L.

    2011-01-01

    Photonics is a leading approach in realizing future quantum technologies and recently, optical waveguide circuits on silicon chips have demonstrated high levels of miniaturization and performance. Multimode interference (MMI) devices promise a straightforward implementation of compact and robust multiport circuits. Here, we show quantum interference in a 2×2 MMI coupler with visibility of V=95.6±0.9%. We further demonstrate the operation of a 4×4 port MMI device with photon pairs, which exhibits complex quantum interference behaviour. We have developed a new technique to fully characterize such multiport devices, which removes the need for phase-sensitive measurements and may find applications for a wide range of photonic devices. Our results show that MMI devices can operate in the quantum regime with high fidelity and promise substantial simplification and concatenation of photonic quantum circuits. PMID:21364563

  3. Proposal of ultra-compact NAND/NOR/XNOR all-optical logic gates based on a nonlinear 3x1 multimode interference

    NASA Astrophysics Data System (ADS)

    Tajaldini, Mehdi; Mat Jafri, M. Z.

    2014-05-01

    We present a highly miniaturized multimode interference (MMI) coupler based on nonlinear modal propagation analysis (NMPA) method as a novel design method and potential application for optical NAND, NOR and XNOR logic gates for Boolean logic signal processing devices. Crystalline polydiacetylene is used to allow the appearances of nonlinear effects in low input intensities and ultra- short length to control the MMI coupler as an active device to access light switching due to its high nonlinear susceptibility. We consider a 10x33 μm2 MMI structure with three inputs and one output. Notably, the access facets are single-mode waveguides with sub-micron width. The center input contributes to control the induced light propagation in MMI by intensity variation whereas others could be launched by particular intensity when they are ON and 0 in OFF. Output intensity is analyzed in various sets of inputs to show the capability of Boolean logic gates, the contrast between ON and OFF is calculated on mentioned gates to present the efficiency. Good operation in low intensity and highly miniaturized MMI coupler is observed. Furthermore, nonlinear effects could be realized through the modal interferences. The issue of high insertion loss is addressed with a 3×3 upgraded coupler. Furthermore, the main significant aspect of this paper is simulating an MMI coupler that is launched by three nonlinear inputs, simultaneously, whereas last presents have never studied more than one input in nonlinear regimes.

  4. Validity evidence for the Hamburg multiple mini-interview.

    PubMed

    Knorr, Mirjana; Schwibbe, Anja; Ehrhardt, Maren; Lackamp, Janina; Zimmermann, Stefan; Hampe, Wolfgang

    2018-05-14

    Multiple mini-interviews (MMI) become increasingly popular for the selection of medical students. In this work, we examine the validity evidence for the Hamburg MMI. We conducted three follow-up studies for the 2014 cohort of applicants to medical school over the course of two years. We calculated Spearman's rank correlation (ρ) between MMI results and (1) emotional intelligence measured by the Trait Emotional Intelligence Questionnaire (TEIQue-SF) and the Situational Test of Emotion Management (STEM), (2) supervisors' and practice team members' evaluations of psychosocial competencies and suitability for the medical profession after a one-week 1:1 teaching in a general practice (GP) and (3) objective structured clinical examination (OSCE) scores. There were no significant correlations between MMI results and the TEIQue-SF (ρ = .07, p > .05) or the STEM (ρ = .05, p > .05). MMI results could significantly predict GP evaluations of psychosocial competencies (ρ = .32, p < .05) and suitability for the medical profession (ρ = .42, p < .01) as well as OSCE scores (ρ = .23, p < .05). The MMI remained a significant predictor of these outcomes in a robust regression model including gender and age as control variables. Our findings suggest that MMIs can measure competencies that are relevant in a practical context. However, these competencies do not seem to be related to emotional intelligence as measured by self-report or situational judgement test.

  5. Self-assembling fluidic machines

    NASA Astrophysics Data System (ADS)

    Grzybowski, Bartosz A.; Radkowski, Michal; Campbell, Christopher J.; Lee, Jessamine Ng; Whitesides, George M.

    2004-03-01

    This letter describes dynamic self-assembly of two-component rotors floating at the interface between liquid and air into simple, reconfigurable mechanical systems ("machines"). The rotors are powered by an external, rotating magnetic field, and their positions within the interface are controlled by: (i) repulsive hydrodynamic interactions between them and (ii) by localized magnetic fields produced by an array of small electromagnets located below the plane of the interface. The mechanical functions of the machines depend on the spatiotemporal sequence of activation of the electromagnets.

  6. Design Control Systems of Human Machine Interface in the NTVS-2894 Seat Grinder Machine to Increase the Productivity

    NASA Astrophysics Data System (ADS)

    Ardi, S.; Ardyansyah, D.

    2018-02-01

    In the Manufacturing of automotive spare parts, increased sales of vehicles is resulted in increased demand for production of engine valve of the customer. To meet customer demand, we carry out improvement and overhaul of the NTVS-2894 seat grinder machine on a machining line. NTVS-2894 seat grinder machine has been decreased machine productivity, the amount of trouble, and the amount of downtime. To overcome these problems on overhaul the NTVS-2984 seat grinder machine include mechanical and programs, is to do the design and manufacture of HMI (Human Machine Interface) GP-4501T program. Because of the time prior to the overhaul, NTVS-2894 seat grinder machine does not have a backup HMI (Human Machine Interface) program. The goal of the design and manufacture in this program is to improve the achievement of production, and allows an operator to operate beside it easier to troubleshoot the NTVS-2894 seat grinder machine thereby reducing downtime on the NTVS-2894 seat grinder machine. The results after the design are HMI program successfully made it back, machine productivity increased by 34.8%, the amount of trouble, and downtime decreased 40% decrease from 3,160 minutes to 1,700 minutes. The implication of our design, it could facilitate the operator in operating machine and the technician easer to maintain and do the troubleshooting the machine problems.

  7. Design and analysis of O-S-C triple band wavelength division demultiplexer using cascaded MMI couplers

    NASA Astrophysics Data System (ADS)

    Chack, Devendra; Kumar, V.; Raghuwanshi, Sanjeev Kumar; Singh, Dev Prakash

    2017-01-01

    Compact triple O-S-C band wavelength demultiplexer, which consists of series cascaded multimode interference (MMI) couplers has been carried out in this paper. The MMI coupler has been used to drop the wavelengths of 1510 nm and 1550 nm at bar port while the wavelength 1300 nm into the cross port. Then another MMI coupler has been designed to separate the wavelength 1510 nminto one port and wavelength 1550 nm into another port. The triple wavelength demultiplexer function has been performed by choosing a suitable refractive index of the guiding region and geometrical parameters such as the width and length of MMI coupler. Numerical simulation with finite difference beam propagation method (BPM) has been utilized to design and optimize the operation of the proposed triple wavelength demultiplexer. The simulation results show that insertion losses of wavelength O, S and C, bands are 1.884 dB, 1.452 dB and 2.568 dB, respectively, with isolations for each output waveguide ranging from 10 dB to 28.72 dB. The 3-dB bandwidth of insertion loss for 1300 nm, 1510 nm and 1550 nm are 80 nm, 20 nm and 10 nm, respectively.

  8. Wide range optofluidically tunable multimode interference fiber laser

    NASA Astrophysics Data System (ADS)

    Antonio-Lopez, J. E.; Sanchez-Mondragon, J. J.; LiKamWa, P.; May-Arrioja, D. A.

    2014-08-01

    An optofluidically tunable fiber laser based on multimode interference (MMI) effects with a wide tuning range is proposed and demonstrated. The tunable mechanism is based on an MMI fiber filter fabricated using a special fiber known as no-core fiber, which is a multimode fiber (MMF) without cladding. Therefore, when the MMI filter is covered by liquid the optical properties of the no-core fiber are modified, which allow us to tune the peak wavelength response of the MMI filter. Rather than applying the liquid on the entire no-core fiber, we change the liquid level along the no-core fiber, which provides a highly linear tuning response. In addition, by selecting the adequate refractive index of the liquid we can also choose the tuning range. We demonstrate the versatility of the optofluidically tunable MMI filter by wavelength tuning two different gain media, erbium doped fiber and a semiconductor optical amplifier, achieving tuning ranges of 55 and 90 nm respectively. In both cases, we achieve side-mode suppression ratios (SMSR) better than 50 dBm with output power variations of less than 0.76 dBm over the whole tuning range.

  9. Two kinds of novel tunable Thulium-doped fiber laser

    NASA Astrophysics Data System (ADS)

    Ma, Xiaowei; Chen, Daru; Feng, Gaofeng; Yang, Junyong

    2014-11-01

    Two kinds of tunable Thulium-doped fiber laser (TDFL) respectively using a Sagnac loop mirror and a novel tunable multimode interference (MMI) fiber filter are experimentally demonstrated. The TDFL with the Sagnac loop mirror made by a 145.5-cm polarization-maintaining fiber (PMF) can operate with stable dual-wavelength lasing or tunable single-wavelength lasing around 1860nm. Both stable dual-wavelength and tunable single-wavelength lasing are achieved by adjusting a polarization controller in the Sagnac loop mirror. The TDFL with a novel tunable MMI fiber filter formed by splicing a segment of a special no-core fiber that is an all silica fiber without fiber core to single mode fibers can achieve tuning range from 1813.52 nm to 1858.70 nm. The no-core fiber with a large diameter of 200 μm is gradually vertically covered by refractive index matching liquid, which leads to a wavelength tuning of the transmission peak of the MMI fiber filter. The relationship between the refractive index of the refractive index matching liquid and the peak wavelength shift of the MMI fiber filter is also discussed. Using the MMI fiber filter, a Thulium-doped fiber laser with a tuning range of 45.18 nm is demonstrated.

  10. A microfluidic multi-injector for gradient generation.

    PubMed

    Chung, Bong Geun; Lin, Francis; Jeon, Noo Li

    2006-06-01

    This paper describes a microfluidic multi-injector (MMI) that can generate temporal and spatial concentration gradients of soluble molecules. Compared to conventional glass micropipette-based methods that generate a single gradient, the MMI exploits microfluidic integration and actuation of multiple pulsatile injectors to generate arbitrary overlapping gradients that have not previously been possible. The MMI device is fabricated in poly(dimethylsiloxane) (PDMS) using multi-layer soft lithography and consists of fluidic channels and control channels with pneumatically actuated on-chip barrier valves. Repetitive actuation of on-chip valves control pulsatile release of solution that establishes microscopic chemical gradients around the orifice. The volume of solution released per actuation cycle ranged from 30 picolitres to several hundred picolitres and increased linearly with the duration of valve opening. The shape of the measured gradient profile agreed closely with the simulated diffusion profile from a point source. Steady state gradient profiles could be attained within 10 minutes, or less with an optimized pulse sequence. Overlapping gradients from 2 injectors were generated and characterized to highlight the advantages of MMI over conventional micropipette assays. The MMI platform should be useful for a wide range of basic and applied studies on chemotaxis and axon guidance.

  11. Gloved Human-Machine Interface

    NASA Technical Reports Server (NTRS)

    Adams, Richard (Inventor); Hannaford, Blake (Inventor); Olowin, Aaron (Inventor)

    2015-01-01

    Certain exemplary embodiments can provide a system, machine, device, manufacture, circuit, composition of matter, and/or user interface adapted for and/or resulting from, and/or a method and/or machine-readable medium comprising machine-implementable instructions for, activities that can comprise and/or relate to: tracking movement of a gloved hand of a human; interpreting a gloved finger movement of the human; and/or in response to interpreting the gloved finger movement, providing feedback to the human.

  12. Diverse applications of advanced man-telerobot interfaces

    NASA Technical Reports Server (NTRS)

    Mcaffee, Douglas A.

    1991-01-01

    Advancements in man-machine interfaces and control technologies used in space telerobotics and teleoperators have potential application wherever human operators need to manipulate multi-dimensional spatial relationships. Bilateral six degree-of-freedom position and force cues exchanged between the user and a complex system can broaden and improve the effectiveness of several diverse man-machine interfaces.

  13. Interface Metaphors for Interactive Machine Learning

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Jasper, Robert J.; Blaha, Leslie M.

    To promote more interactive and dynamic machine learn- ing, we revisit the notion of user-interface metaphors. User-interface metaphors provide intuitive constructs for supporting user needs through interface design elements. A user-interface metaphor provides a visual or action pattern that leverages a user’s knowledge of another domain. Metaphors suggest both the visual representations that should be used in a display as well as the interactions that should be afforded to the user. We argue that user-interface metaphors can also offer a method of extracting interaction-based user feedback for use in machine learning. Metaphors offer indirect, context-based information that can be usedmore » in addition to explicit user inputs, such as user-provided labels. Implicit information from user interactions with metaphors can augment explicit user input for active learning paradigms. Or it might be leveraged in systems where explicit user inputs are more challenging to obtain. Each interaction with the metaphor provides an opportunity to gather data and learn. We argue this approach is especially important in streaming applications, where we desire machine learning systems that can adapt to dynamic, changing data.« less

  14. Overlapping-image multimode interference couplers with a reduced number of self-images for uniform and nonuniform power splitting

    NASA Astrophysics Data System (ADS)

    Bachmann, M.; Besse, P. A.; Melchior, H.

    1995-10-01

    Overlapping-image multimode interference (MMI) couplers, a new class of devices, permit uniform and nonuniform power splitting. A theoretical description directly relates coupler geometry to image intensities, positions, and phases. Among many possibilities of nonuniform power splitting, examples of 1 \\times 2 couplers with ratios of 15:85 and 28:72 are given. An analysis of uniform power splitters includes the well-known 2 \\times N and 1 \\times N MMI couplers. Applications of MMI couplers include mode filters, mode splitters-combiners, and mode converters.

  15. Widely tunable erbium-doped fiber laser based on multimode interference effect.

    PubMed

    Castillo-Guzman, A; Antonio-Lopez, J E; Selvas-Aguilar, R; May-Arrioja, D A; Estudillo-Ayala, J; LiKamWa, P

    2010-01-18

    A widely tunable erbium-doped all-fiber laser has been demonstrated. The tunable mechanism is based on a novel tunable filter using multimode interference effects (MMI). The tunable MMI filter was applied to fabricate a tunable erbium-doped fiber laser via a standard ring cavity. A tuning range of 60 nm was obtained, ranging from 1549 nm to 1609 nm, with a signal to noise ratio of 40 dB. The tunable MMI filter mechanism is very simple and inexpensive, but also quite efficient as a wavelength tunable filter.

  16. Feasibility of task-specific brain-machine interface training for upper-extremity paralysis in patients with chronic hemiparetic stroke.

    PubMed

    Nishimoto, Atsuko; Kawakami, Michiyuki; Fujiwara, Toshiyuki; Hiramoto, Miho; Honaga, Kaoru; Abe, Kaoru; Mizuno, Katsuhiro; Ushiba, Junichi; Liu, Meigen

    2018-01-10

    Brain-machine interface training was developed for upper-extremity rehabilitation for patients with severe hemiparesis. Its clinical application, however, has been limited because of its lack of feasibility in real-world rehabilitation settings. We developed a new compact task-specific brain-machine interface system that enables task-specific training, including reach-and-grasp tasks, and studied its clinical feasibility and effectiveness for upper-extremity motor paralysis in patients with stroke. Prospective beforeâ€"after study. Twenty-six patients with severe chronic hemiparetic stroke. Participants were trained with the brain-machine interface system to pick up and release pegs during 40-min sessions and 40 min of standard occupational therapy per day for 10 days. Fugl-Meyer upper-extremity motor (FMA) and Motor Activity Log-14 amount of use (MAL-AOU) scores were assessed before and after the intervention. To test its feasibility, 4 occupational therapists who operated the system for the first time assessed it with the Quebec User Evaluation of Satisfaction with assistive Technology (QUEST) 2.0. FMA and MAL-AOU scores improved significantly after brain-machine interface training, with the effect sizes being medium and large, respectively (p<0.01, d=0.55; p<0.01, d=0.88). QUEST effectiveness and safety scores showed feasibility and satisfaction in the clinical setting. Our newly developed compact brain-machine interface system is feasible for use in real-world clinical settings.

  17. Shell stability and conditions analyzed using a new method of extracting shell areal density maps from spectrally resolved images of direct-drive inertial confinement fusion implosions

    DOE PAGES

    Johns, H. M.; Mancini, R. C.; Nagayama, T.; ...

    2016-01-25

    In warm target direct-drive inertial confinement fusion implosion experiments performed at the OMEGA laser facility, plastic micro-balloons doped with a titanium tracer layer in the shell and filled with deuterium gas were imploded using a low-adiabat shaped laser pulse. Continuum radiation emitted in the core is transmitted through the tracer layer and the resulting spectrum recorded with a gated multi-monochromatic x-ray imager (MMI). Titanium K-shell line absorption spectra observed in the data are due to transitions in L-shell titanium ions driven by the backlighting continuum. The MMI data consist of an array of spectrally resolved images of the implosion. Thesemore » 2-D space-resolved titanium spectral features constrain the plasma conditions and areal density of the titanium doped region of the shell. The MMI data were processed to obtain narrow-band images and space resolved spectra of titanium spectral features. Shell areal density maps, ρL(x,y), extracted using a new method using both narrow-band images and space resolved spectra are confirmed to be consistent within uncertainties. We report plasma conditions in the titanium-doped region of electron temperature (Te) = 400 ± 28 eV, electron number density (N e) = 8.5 × 10 24 ± 2.5 × 10 24 cm –3, and average areal density = 86 ± 7 mg/cm 2. Fourier analysis of areal density maps reveals shell modulations caused by hydrodynamic instability growth near the fuel-shell interface in the deceleration phase. We observe significant structure in modes l = 2–9, dominated by l = 2. We extract a target breakup fraction of 7.1 ± 1.5% from our Fourier analysis. Furthermore, a new method for estimating mix width is evaluated against existing literature and our target breakup fraction. We estimate a mix width of 10.5 ±1 μm.« less

  18. Science Applications of a Multispectral Microscopic Imager for the Astrobiological Exploration of Mars

    PubMed Central

    Farmer, Jack D.; Sellar, R. Glenn; Swayze, Gregg A.; Blaney, Diana L.

    2014-01-01

    Abstract Future astrobiological missions to Mars are likely to emphasize the use of rovers with in situ petrologic capabilities for selecting the best samples at a site for in situ analysis with onboard lab instruments or for caching for potential return to Earth. Such observations are central to an understanding of the potential for past habitable conditions at a site and for identifying samples most likely to harbor fossil biosignatures. The Multispectral Microscopic Imager (MMI) provides multispectral reflectance images of geological samples at the microscale, where each image pixel is composed of a visible/shortwave infrared spectrum ranging from 0.46 to 1.73 μm. This spectral range enables the discrimination of a wide variety of rock-forming minerals, especially Fe-bearing phases, and the detection of hydrated minerals. The MMI advances beyond the capabilities of current microimagers on Mars by extending the spectral range into the infrared and increasing the number of spectral bands. The design employs multispectral light-emitting diodes and an uncooled indium gallium arsenide focal plane array to achieve a very low mass and high reliability. To better understand and demonstrate the capabilities of the MMI for future surface missions to Mars, we analyzed samples from Mars-relevant analog environments with the MMI. Results indicate that the MMI images faithfully resolve the fine-scale microtextural features of samples and provide important information to help constrain mineral composition. The use of spectral endmember mapping reveals the distribution of Fe-bearing minerals (including silicates and oxides) with high fidelity, along with the presence of hydrated minerals. MMI-based petrogenetic interpretations compare favorably with laboratory-based analyses, revealing the value of the MMI for future in situ rover-mediated astrobiological exploration of Mars. Key Words: Mars—Microscopic imager—Multispectral imaging—Spectroscopy—Habitability—Arm instrument. Astrobiology 14, 132–169. PMID:24552233

  19. Flexible software architecture for user-interface and machine control in laboratory automation.

    PubMed

    Arutunian, E B; Meldrum, D R; Friedman, N A; Moody, S E

    1998-10-01

    We describe a modular, layered software architecture for automated laboratory instruments. The design consists of a sophisticated user interface, a machine controller and multiple individual hardware subsystems, each interacting through a client-server architecture built entirely on top of open Internet standards. In our implementation, the user-interface components are built as Java applets that are downloaded from a server integrated into the machine controller. The user-interface client can thereby provide laboratory personnel with a familiar environment for experiment design through a standard World Wide Web browser. Data management and security are seamlessly integrated at the machine-controller layer using QNX, a real-time operating system. This layer also controls hardware subsystems through a second client-server interface. This architecture has proven flexible and relatively easy to implement and allows users to operate laboratory automation instruments remotely through an Internet connection. The software architecture was implemented and demonstrated on the Acapella, an automated fluid-sample-processing system that is under development at the University of Washington.

  20. Low Latency Messages on Distributed Memory Multiprocessors

    DOE PAGES

    Rosing, Matt; Saltz, Joel

    1995-01-01

    This article describes many of the issues in developing an efficient interface for communication on distributed memory machines. Although the hardware component of message latency is less than 1 ws on many distributed memory machines, the software latency associated with sending and receiving typed messages is on the order of 50 μs. The reason for this imbalance is that the software interface does not match the hardware. By changing the interface to match the hardware more closely, applications with fine grained communication can be put on these machines. This article describes several tests performed and many of the issues involvedmore » in supporting low latency messages on distributed memory machines.« less

  1. Defining brain-machine interface applications by matching interface performance with device requirements.

    PubMed

    Tonet, Oliver; Marinelli, Martina; Citi, Luca; Rossini, Paolo Maria; Rossini, Luca; Megali, Giuseppe; Dario, Paolo

    2008-01-15

    Interaction with machines is mediated by human-machine interfaces (HMIs). Brain-machine interfaces (BMIs) are a particular class of HMIs and have so far been studied as a communication means for people who have little or no voluntary control of muscle activity. In this context, low-performing interfaces can be considered as prosthetic applications. On the other hand, for able-bodied users, a BMI would only be practical if conceived as an augmenting interface. In this paper, a method is introduced for pointing out effective combinations of interfaces and devices for creating real-world applications. First, devices for domotics, rehabilitation and assistive robotics, and their requirements, in terms of throughput and latency, are described. Second, HMIs are classified and their performance described, still in terms of throughput and latency. Then device requirements are matched with performance of available interfaces. Simple rehabilitation and domotics devices can be easily controlled by means of BMI technology. Prosthetic hands and wheelchairs are suitable applications but do not attain optimal interactivity. Regarding humanoid robotics, the head and the trunk can be controlled by means of BMIs, while other parts require too much throughput. Robotic arms, which have been controlled by means of cortical invasive interfaces in animal studies, could be the next frontier for non-invasive BMIs. Combining smart controllers with BMIs could improve interactivity and boost BMI applications.

  2. Effects of selenium on short-term control of hyperthyroidism due to Graves' disease treated with methimazole: results of a randomized clinical trial.

    PubMed

    Leo, M; Bartalena, L; Rotondo Dottore, G; Piantanida, E; Premoli, P; Ionni, I; Di Cera, M; Masiello, E; Sassi, L; Tanda, M L; Latrofa, F; Vitti, P; Marcocci, C; Marinò, M

    2017-03-01

    In spite of previous conflicting results, an adjuvant role of selenium in the treatment of Graves' disease (GD) hyperthyroidism has been proposed. To address this issue, a randomized clinical trial was carried out aimed at investigating whether selenium is beneficial on the short-term control of GD hyperthyroidism treated with methimazole (MMI). Thirty newly diagnosed hyperthyroid GD patients were randomly assigned to treatment with: (i) MMI or (ii) MMI plus selenium. Primary outcomes were: control of hyperthyroidism and clinical and biochemical manifestations of hyperthyroidism [heart rate, cholesterol, sex hormone-binding globulin (SHBG), hyperthyroidism symptoms] at 90 days. Baseline features of the two groups did not differ. Serum selenium at baseline was similar in the two groups and within the recommended range to define selenium sufficiency. Selenium increased with treatment in the MMI-selenium group and became significantly higher than in the MMI group. Serum malondialdehyde, a marker of oxidative stress, was similar in the two groups and decreased significantly with treatment, with no difference between groups. Administration of MMI was followed by a reduction of FT 3 and FT 4 , with no difference between groups. Heart rate, SHBG and symptoms of hyperthyroidism decreased, whereas total cholesterol increased in both groups with no difference between groups. Our study, carried out in a selenium-sufficient cohort of GD patients, failed to show an adjuvant role of selenium in the short-term control of hyperthyroidism. However, selenium might be beneficial in patients from selenium-deficient areas, as well as in the long-term outcome of antithyroid treatment.

  3. Utility of a writing station in the multiple mini-interview.

    PubMed

    Raghavan, Malathi; Burnett, Margaret; Martin, Bruce D; Christensen, Heather; Young, Deborah G; Mackalski, Barbara; Aoki, Fred

    2013-01-01

    The multiple mini-interview (MMI) is a reliable and valid method of selecting applicants for admission to health professional schools on the basis of non-cognitive traits. Because the MMI is a series of short interview stations that applicants rotate through in coordinated sequence, it can potentially be resource intensive. However, the MMI design has room for innovation and efficiency. At the University of Manitoba Faculty of Medicine, a 10-minute unsupervised writing station (WS) was incorporated into the MMI to obtain a writing sample from each applicant, to increase the number of independent scores per applicant, and to increase the number of applicants interviewed per circuit without increasing interviewer numbers. One assessor evaluated all the writing samples and assigned a score ranging from 1 to 7. With the inclusion of a WS into an 11-station MMI, the faculty's capacity to interview applicants increased by 9% (from 297 to 324) without substantially increasing interviewer hours needed per day. For 1,257 applicants interviewed in 2008-2011, the mean WS score was 4.03 (SD=1.36), whereas applicants' mean of 10 oral station (OS) scores was 4.62 (SD=0.69). Correlations between WS score and mean OS score ranged from .16 to .27 (p<.01) over the four years. Because inter-station correlations for OS ranged from .01 to .37, the correlation of .21 between WS and mean OS scores for all four years combined appears reasonable. Institutions that want to effectively increase the capacity of their MMI process might consider adding a WS.

  4. Thyroid organotypic rat and human cultures used to investigate drug effects on thyroid function, hormone synthesis and release pathways

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Vickers, Alison E.M., E-mail: vickers_alison@allergan.com; Heale, Jason; Sinclair, John R.

    Drug induced thyroid effects were evaluated in organotypic models utilizing either a rat thyroid lobe or human thyroid slices to compare rodent and human response. An inhibition of thyroid peroxidase (TPO) function led to a perturbation in the expression of key genes in thyroid hormone synthesis and release pathways. The clinically used thiourea drugs, methimazole (MMI) and 6-n-propyl-2-thioruacil (PTU), were used to evaluate thyroid drug response in these models. Inhibition of TPO occurred early as shown in rat thyroid lobes (2 h) and was sustained in both rat (24–48 h) and human (24 h) with ≥ 10 μM MMI. Thyroidmore » from rats treated with single doses of MMI (30–1000 mg/kg) exhibited sustained TPO inhibition at 48 h. The MMI in vivo thyroid concentrations were comparable to the culture concentrations (∼ 15–84 μM), thus demonstrating a close correlation between in vivo and ex vivo thyroid effects. A compensatory response to TPO inhibition was demonstrated in the rat thyroid lobe with significant up-regulation of genes involved in the pathway of thyroid hormone synthesis (Tpo, Dio1, Slc5a5, Tg, Tshr) and the megalin release pathway (Lrp2) by 24 h with MMI (≥ 10 μM) and PTU (100 μM). Similarly, thyroid from the rat in vivo study exhibited an up-regulation of Dio1, Slc5a5, Lrp2, and Tshr. In human thyroid slices, there were few gene expression changes (Slc5a5, ∼ 2-fold) and only at higher MMI concentrations (≥ 1500 μM, 24 h). Extended exposure (48 h) resulted in up-regulation of Tpo, Dio1 and Lrp2, along with Slc5a5 and Tshr. In summary, TPO was inhibited by similar MMI concentrations in rat and human tissue, however an increased sensitivity to drug treatment in rat is indicated by the up-regulation of thyroid hormone synthesis and release gene pathways at concentrations found not to affect human tissue. -- Highlights: ► Novel model of rat thyroid or human thyroid slices to evaluate pathways of injury. ► TPO inhibition by MMI or PTU altered hormone synthesis and release genes. ► Rat thyroid was more sensitive to the drug effects than human tissue.« less

  5. A Function-Behavior-State Approach to Designing Human Machine Interface for Nuclear Power Plant Operators

    NASA Astrophysics Data System (ADS)

    Lin, Y.; Zhang, W. J.

    2005-02-01

    This paper presents an approach to human-machine interface design for control room operators of nuclear power plants. The first step in designing an interface for a particular application is to determine information content that needs to be displayed. The design methodology for this step is called the interface design framework (called framework ). Several frameworks have been proposed for applications at varying levels, including process plants. However, none is based on the design and manufacture of a plant system for which the interface is designed. This paper presents an interface design framework which originates from design theory and methodology for general technical systems. Specifically, the framework is based on a set of core concepts of a function-behavior-state model originally proposed by the artificial intelligence research community and widely applied in the design research community. Benefits of this new framework include the provision of a model-based fault diagnosis facility, and the seamless integration of the design (manufacture, maintenance) of plants and the design of human-machine interfaces. The missing linkage between design and operation of a plant was one of the causes of the Three Mile Island nuclear reactor incident. A simulated plant system is presented to explain how to apply this framework in designing an interface. The resulting human-machine interface is discussed; specifically, several fault diagnosis examples are elaborated to demonstrate how this interface could support operators' fault diagnosis in an unanticipated situation.

  6. Bilateral Medial Medullary Infarction with Nondominant Vertebral Artery Occlusion.

    PubMed

    Zhang, Lei; Zhang, Gui-lian; Du, Ju-mei; Ma, Zhu-lin

    2015-09-01

    Bilateral medial medullary infarction (MMI) is a rare stroke subtype. Here, we report a case with bilateral MMI caused by nondominant vertebral artery occlusion confirmed by brain digital subtraction angiography and magnetic resonance imaging basi-parallel-anatomical-scanning. We highlight that anterior spinal arteries could originate from a unilateral vertebral artery (VA). Radiologists and neurologists should pay attention to the nondominant VA as bilateral MMI may be induced by occlusion of nondominant VA that supplies the bilateral anteromedial territories of the medulla. Copyright © 2015 National Stroke Association. Published by Elsevier Inc. All rights reserved.

  7. First experience with multiple mini interview for medical school admission in Brazil: Does it work in a different cultural scenario?

    PubMed

    Daniel-Filho, Durval Anibal; Pires, Elda Maria Stafuzza Gonçalves; Paes, Angela Tavares; Troster, Eduardo Juan; Silva, Simone Cristina Azevedo B S; Granato, Mariana Fachini; Couto, Thomaz Bittencourt; Barreto, Joyce Kelly Silva; Campos, Alexandre Holthausen; Monte, Julio C Martins; Schvartsman, Claudio

    2017-10-01

    Evaluation of non-cognitive skills never has been used in Brazil. This study aims to evaluate Multiple Mini Interviews (MMI) in the admission process of a School of Medicine in São Paulo, Brazil. The population of the study comprised 240 applicants summoned for the interviews, and 96 raters. MMI contributed to 25% of the applicants' final grade. Eight scenarios were created with the aim of evaluating different non-cognitive skills, each one had two raters. At the end of the interviews, the applicants and raters described their impressions about MMI. The reliability of the MMI was analyzed using the Theory of Generalization and Many-Facet Rasch Model (MFRM). The G-study showed that the general reliability of the process was satisfactory (coefficient G = 0.743). The MMI grades were not affected by the raters' profile, time of interview (p = 0.715), and randomization group (p = 0.353). The Rasch analysis showed that there was no misfitting effects or inconsistent stations or raters. A significant majority of the applicants (98%) and all the raters believed MMIs were important in selecting students with a more adequate profile to study medicine. The general reliability of the selection process was excellent, and it was fully accepted by the applicants and raters.

  8. MMI's Metadata and Vocabulary Solutions: 10 Years and Growing

    NASA Astrophysics Data System (ADS)

    Graybeal, J.; Gayanilo, F.; Rueda-Velasquez, C. A.

    2014-12-01

    The Marine Metadata Interoperability project (http://marinemetadata.org) held its public opening at AGU's 2004 Fall Meeting. For 10 years since that debut, the MMI guidance and vocabulary sites have served over 100,000 visitors, with 525 community members and continuous Steering Committee leadership. Originally funded by the National Science Foundation, over the years multiple organizations have supported the MMI mission: "Our goal is to support collaborative research in the marine science domain, by simplifying the incredibly complex world of metadata into specific, straightforward guidance. MMI encourages scientists and data managers at all levels to apply good metadata practices from the start of a project, by providing the best guidance and resources for data management, and developing advanced metadata tools and services needed by the community." Now hosted by the Harte Research Institute at Texas A&M University at Corpus Christi, MMI continues to provide guidance and services to the community, and is planning for marine science and technology needs for the next 10 years. In this presentation we will highlight our major accomplishments, describe our recent achievements and imminent goals, and propose a vision for improving marine data interoperability for the next 10 years, including Ontology Registry and Repository (http://mmisw.org/orr) advancements and applications (http://mmisw.org/cfsn).

  9. Low latency messages on distributed memory multiprocessors

    NASA Technical Reports Server (NTRS)

    Rosing, Matthew; Saltz, Joel

    1993-01-01

    Many of the issues in developing an efficient interface for communication on distributed memory machines are described and a portable interface is proposed. Although the hardware component of message latency is less than one microsecond on many distributed memory machines, the software latency associated with sending and receiving typed messages is on the order of 50 microseconds. The reason for this imbalance is that the software interface does not match the hardware. By changing the interface to match the hardware more closely, applications with fine grained communication can be put on these machines. Based on several tests that were run on the iPSC/860, an interface that will better match current distributed memory machines is proposed. The model used in the proposed interface consists of a computation processor and a communication processor on each node. Communication between these processors and other nodes in the system is done through a buffered network. Information that is transmitted is either data or procedures to be executed on the remote processor. The dual processor system is better suited for efficiently handling asynchronous communications compared to a single processor system. The ability to send data or procedure is very flexible for minimizing message latency, based on the type of communication being performed. The test performed and the proposed interface are described.

  10. Automated visual imaging interface for the plant floor

    NASA Astrophysics Data System (ADS)

    Wutke, John R.

    1991-03-01

    The paper will provide an overview of the challenges facing a user of automated visual imaging (" AVI" ) machines and the philosophies that should be employed in designing them. As manufacturing tools and equipment become more sophisticated it is increasingly difficult to maintain an efficient interaction between the operator and machine. The typical user of an AVI machine in a production environment is technically unsophisticated. Also operator and machine ergonomics are often a neglected or poorly addressed part of an efficient manufacturing process. This paper presents a number of man-machine interface design techniques and philosophies that effectively solve these problems.

  11. Analysis and design of arrayed waveguide gratings with MMI couplers.

    PubMed

    Munoz, P; Pastor, D; Capmany, J

    2001-09-24

    We present an extension of the AWG model and design procedure described in [1] to incorporate multimode interference, MMI, couplers. For the first time to our knowledge, a closed formula for the passing bands bandwidth and crosstalk estimation plots are derived.

  12. Understanding reliability and some limitations of the images and spectra reconstructed from a multi-monochromatic x-ray imager

    DOE PAGES

    Nagayama, T.; Mancini, R. C.; Mayes, D.; ...

    2015-11-18

    Temperature and density asymmetry diagnosis is critical to advance inertial confinement fusion (ICF) science. A multi-monochromatic x-ray imager (MMI) is an attractive diagnostic for this purpose. The MMI records the spectral signature from an ICF implosion core with time resolution, 2-D space resolution, and spectral resolution. While narrow-band images and 2-D space-resolved spectra from the MMI data constrain temperature and density spatial structure of the core, the accuracy of the images and spectra depends not only on the quality of the MMI data but also on the reliability of the post-processing tools. In this paper, we synthetically quantify the accuracymore » of images and spectra reconstructed from MMI data. Errors in the reconstructed images are less than a few percent when the space-resolution effect is applied to the modeled images. The errors in the reconstructed 2-D space-resolved spectra are also less than a few percent except those for the peripheral regions. Spectra reconstructed for the peripheral regions have slightly but systematically lower intensities by ~6% due to the instrumental spatial-resolution effects. However, this does not alter the relative line ratios and widths and thus does not affect the temperature and density diagnostics. We also investigate the impact of the pinhole size variation on the extracted images and spectra. A 10% pinhole size variation could introduce spatial bias to the images and spectra of ~10%. A correction algorithm is developed, and it successfully reduces the errors to a few percent. Finally, it is desirable to perform similar synthetic investigations to fully understand the reliability and limitations of each MMI application.« less

  13. Deeply etched MMI-based components on 4 μm thick SOI for SOA-based optical RAM cell circuits

    NASA Astrophysics Data System (ADS)

    Cherchi, Matteo; Ylinen, Sami; Harjanne, Mikko; Kapulainen, Markku; Aalto, Timo; Kanellos, George T.; Fitsios, Dimitrios; Pleros, Nikos

    2013-02-01

    We present novel deeply etched functional components, fabricated by multi-step patterning in the frame of our 4 μm thick Silicon on Insulator (SOI) platform based on singlemode rib-waveguides and on the previously developed rib-tostrip converter. These novel components include Multi-Mode Interference (MMI) splitters with any desired splitting ratio, wavelength sensitive 50/50 splitters with pre-filtering capability, multi-stage Mach-Zehnder Interferometer (MZI) filters for suppression of Amplified Spontaneous Emission (ASE), and MMI resonator filters. These novel building blocks enable functionalities otherwise not achievable on our SOI platform, and make it possible to integrate optical RAM cell layouts, by resorting to our technology for hybrid integration of Semiconductor Optical Amplifiers (SOAs). Typical SOA-based RAM cell layouts require generic splitting ratios, which are not readily achievable by a single MMI splitter. We present here a novel solution to this problem, which is very compact and versatile and suits perfectly our technology. Another useful functional element when using SOAs is the pass-band filter to suppress ASE. We pursued two complimentary approaches: a suitable interleaved cascaded MZI filter, based on a novel suitably designed MMI coupler with pre-filtering capabilities, and a completely novel MMI resonator concept, to achieve larger free spectral ranges and narrower pass-band response. Simulation and design principles are presented and compared to preliminary experimental functional results, together with scaling rules and predictions of achievable RAM cell densities. When combined with our newly developed ultra-small light-turning concept, these new components are expected to pave the way for high integration density of RAM cells.

  14. The effect of personality traits on undergraduate dental students' performance in multiple mini interviews.

    PubMed

    Shinawi, Lana Ahmed; Alaki, Sumer Madani; Yamany, Ibrahim; Hassan, Mona Hassan Ahmed

    2017-05-01

    Multiple mini interviews (MMI) is a structured student selection method where applicants rotate around a series of stations that do not require previously learned knowledge. The Big Five Inventory (BFI) is a tool often used to measure personality traits commonly used in applicant selection. The aim of the current study was to assess the effect of personality traits using the BFI on undergraduate dental students' performance in MMI. This research was conducted at The Faculty of Dentistry, King Abdulaziz University, Jeddah, Saudi Arabia. All undergraduates applying to the dental program at King Abdulaziz University, Faculty of Dentistry (KAUFD) in two academic years [(2014-2015) and (2015-2016)] undertook the MMI held at KAUFD and completed the BFI inventory with a total number of 350 students. The MMI consisted of five stations while the BFI contained forty-four items. Data were analysed by SPSS version 20, using independent-samples t-test, Mann-Whitney U test, Spearman's rho correlation coefficient and Chi-square test. female students scored higher than their male counterparts but scores were only significant in the empathy station (p<0.001) in the first year, and in both empathetic skills and team work abilities (p<0.05) in the second. BFI results indicate that male students scored higher on agreeableness (p<0.003) and lower on neuroticism (p<0.001) in the first year while female students scored higher on agreeableness and conscientiousness (p<0.001) in the second year. Students of private schools had higher total MMI scores compared to those of public schools (p<0.05). MMI combined with the Big Five Inventory can be a useful tool in the admission process.

  15. Acute Treatment with T-Type Calcium Channel Enhancer SAK3 Reduces Cognitive Impairments Caused by Methimazole-Induced Hypothyroidism Via Activation of Cholinergic Signaling.

    PubMed

    Husain, Noreen; Yabuki, Yasushi; Shinoda, Yasuharu; Fukunaga, Kohji

    2018-01-01

    Hypothyroidism is a common disorder that is associated with psychological disturbances such as dementia, depression, and psychomotor disorders. We recently found that chronic treatment with the T-type calcium channel enhancer SAK3 prevents the cholinergic neurodegeneration induced by a single intraperitoneal (i.p.) injection of methimazole (MMI; 75 mg/kg), thereby improving cognition. Here, we evaluated the acute effect of SAK3 on cognitive impairments and its mechanism of action following the induction of hypothyroidism. Hypothyroidism was induced by 2 injections of MMI (75 mg/kg, i.p.) administered once per week. Four weeks after the final MMI treatment, MMI-treated mice showed reduced serum thyroxine (T4) levels and cognitive impairments without depression-like behaviors. Although acute SAK3 (1.0 mg/kg, p.o.) administration failed to ameliorate the decreased T4 levels and histochemical destruction of the glomerular structure, acute SAK3 (1.0 mg/kg, p.o.) administration significantly reduced cognitive impairments in MMI-treated mice. Importantly, the α7 nicotinic acetylcholine receptor (nAChR)-selective inhibitor methyllycaconitine (MLA; 12 mg/kg, i.p.) and T-type calcium channel-specific blocker NNC 55-0396 (25 mg/kg, i.p.) antagonized the acute effect of SAK3 on memory deficits in MMI-treated mice. We also confirmed that acute SAK3 administration does not rescue reduced olfactory marker protein or choline acetyltransferase immunoreactivity levels in the olfactory bulb or medial septum. Taken together, these results suggest that SAK3 has the ability to improve the cognitive decline caused by hypothyroidism directly through activation of nAChR signaling and T-type calcium channels. © 2018 S. Karger AG, Basel.

  16. Low elastic modulus Ti-Ta alloys for load-bearing permanent implants: enhancing the biodegradation resistance by electrochemical surface engineering.

    PubMed

    Kesteven, Jazmin; Kannan, M Bobby; Walter, Rhys; Khakbaz, Hadis; Choe, Han-Choel

    2015-01-01

    In this study, the in vitro degradation behaviour of titanium-tantalum (Ti-Ta) alloys (10-30 wt.% Ta) was investigated and compared with conventional implant materials, i.e., commercially pure titanium (Cp-Ti) and titanium-aluminium-vanadium (Ti6Al4V) alloy. Among the three Ti-Ta alloys studied, the Ti20Ta (6.3×10(-4) mm/y) exhibited the lowest degradation rate, followed by Ti30Ta (1.2×10(-3) mm/y) and Ti10Ta (1.4×10(-3) mm/y). All the Ti-Ta alloys exhibited lower degradation rate than that of Cp-Ti (1.8×10(-3) mm/y), which suggests that Ta addition to Ti is beneficial. As compared to Ti6Al4V alloy (8.1×10(-4) mm/y), the degradation rate of Ti20Ta alloy was lower by ~22%. However, the Ti30Ta alloy, which has closer elastic modulus to that of natural bone, showed ~48% higher degradation rate than that of Ti6Al4V alloy. Hence, to improve the degradation performance of Ti30Ta alloy, an intermediate thin porous layer was formed electrochemically on the alloy followed by calcium phosphate (CaP) electrodeposition. The coated Ti30Ta alloy (3.8×10(-3) mm/y) showed ~53% lower degradation rate than that of Ti6Al4V alloy. Thus, the study suggests that CaP coated Ti30Ta alloy can be a viable material for load-bearing permanent implants. Copyright © 2014 Elsevier B.V. All rights reserved.

  17. Double-Blind, Placebo-Controlled, Randomized Trial of Selenium in Graves Hyperthyroidism.

    PubMed

    Kahaly, George J; Riedl, Michaela; König, Jochem; Diana, Tanja; Schomburg, Lutz

    2017-11-01

    Supplemental selenium (Se) may affect the clinical course of Graves disease (GD). Evaluate efficacy of add-on Se on medical treatment in GD. Double-blind, placebo-controlled, randomized supplementation trial. Academic endocrine outpatient clinic. Seventy untreated hyperthyroid patients with GD. Additionally to methimazole (MMI), patients received for 24 weeks either sodium selenite 300 µg/d po or placebo. MMI was discontinued at 24 weeks in euthyroid patients. Response rate (week 24), recurrence rate (week 36), and safety. A response was registered in 25 of 31 patients (80%) and in 27 of 33 (82%) at week 24 [odds ratio (OR) 0.93; 95% confidence interval (CI), 0.26 to 3.25; P = 0.904] in the Se (+MMI) and placebo (+MMI) groups, respectively. During a 12-week follow-up, 11 of 23 (48%) and 12 of 27 (44%) relapsed (OR 1.13; 95% CI, 0.29 to 2.66; P = 0.81) in the Se and placebo groups, respectively. Serum concentrations of Se and selenoprotein P were unrelated to response or recurrence rates. At week 36, 12 of 29 (41%) and 15 of 33 (45%) were responders and still in remission in the Se and placebo groups, respectively (OR 0.85; 95% CI, 0.31 to 2.32; P = 0.80). Serum levels of free triiodothyronine/free tetraiodothyronine, thyroid-stimulating hormone receptor antibody, prevalence of moderate to severe Graves orbitopathy, thyroid volume, and MMI starting dose were significantly lower in responders than in nonresponders. A total of 56 and 63 adverse events occurred in the Se and placebo groups, respectively (P = 0.164), whereas only one drug-related side effect (2.9%) was noted in 35 patients on placebo + MMI. Supplemental Se did not affect response or recurrence rates in GD. Copyright © 2017 Endocrine Society

  18. Understanding reliability and some limitations of the images and spectra reconstructed from a multi-monochromatic x-ray imager

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Nagayama, T.; Mancini, R. C.; Mayes, D.

    2015-11-15

    Temperature and density asymmetry diagnosis is critical to advance inertial confinement fusion (ICF) science. A multi-monochromatic x-ray imager (MMI) is an attractive diagnostic for this purpose. The MMI records the spectral signature from an ICF implosion core with time resolution, 2-D space resolution, and spectral resolution. While narrow-band images and 2-D space-resolved spectra from the MMI data constrain temperature and density spatial structure of the core, the accuracy of the images and spectra depends not only on the quality of the MMI data but also on the reliability of the post-processing tools. Here, we synthetically quantify the accuracy of imagesmore » and spectra reconstructed from MMI data. Errors in the reconstructed images are less than a few percent when the space-resolution effect is applied to the modeled images. The errors in the reconstructed 2-D space-resolved spectra are also less than a few percent except those for the peripheral regions. Spectra reconstructed for the peripheral regions have slightly but systematically lower intensities by ∼6% due to the instrumental spatial-resolution effects. However, this does not alter the relative line ratios and widths and thus does not affect the temperature and density diagnostics. We also investigate the impact of the pinhole size variation on the extracted images and spectra. A 10% pinhole size variation could introduce spatial bias to the images and spectra of ∼10%. A correction algorithm is developed, and it successfully reduces the errors to a few percent. It is desirable to perform similar synthetic investigations to fully understand the reliability and limitations of each MMI application.« less

  19. Understanding reliability and some limitations of the images and spectra reconstructed from a multi-monochromatic x-ray imager.

    PubMed

    Nagayama, T; Mancini, R C; Mayes, D; Tommasini, R; Florido, R

    2015-11-01

    Temperature and density asymmetry diagnosis is critical to advance inertial confinement fusion (ICF) science. A multi-monochromatic x-ray imager (MMI) is an attractive diagnostic for this purpose. The MMI records the spectral signature from an ICF implosion core with time resolution, 2-D space resolution, and spectral resolution. While narrow-band images and 2-D space-resolved spectra from the MMI data constrain temperature and density spatial structure of the core, the accuracy of the images and spectra depends not only on the quality of the MMI data but also on the reliability of the post-processing tools. Here, we synthetically quantify the accuracy of images and spectra reconstructed from MMI data. Errors in the reconstructed images are less than a few percent when the space-resolution effect is applied to the modeled images. The errors in the reconstructed 2-D space-resolved spectra are also less than a few percent except those for the peripheral regions. Spectra reconstructed for the peripheral regions have slightly but systematically lower intensities by ∼6% due to the instrumental spatial-resolution effects. However, this does not alter the relative line ratios and widths and thus does not affect the temperature and density diagnostics. We also investigate the impact of the pinhole size variation on the extracted images and spectra. A 10% pinhole size variation could introduce spatial bias to the images and spectra of ∼10%. A correction algorithm is developed, and it successfully reduces the errors to a few percent. It is desirable to perform similar synthetic investigations to fully understand the reliability and limitations of each MMI application.

  20. MARTI: man-machine animation real-time interface

    NASA Astrophysics Data System (ADS)

    Jones, Christian M.; Dlay, Satnam S.

    1997-05-01

    The research introduces MARTI (man-machine animation real-time interface) for the realization of natural human-machine interfacing. The system uses simple vocal sound-tracks of human speakers to provide lip synchronization of computer graphical facial models. We present novel research in a number of engineering disciplines, which include speech recognition, facial modeling, and computer animation. This interdisciplinary research utilizes the latest, hybrid connectionist/hidden Markov model, speech recognition system to provide very accurate phone recognition and timing for speaker independent continuous speech, and expands on knowledge from the animation industry in the development of accurate facial models and automated animation. The research has many real-world applications which include the provision of a highly accurate and 'natural' man-machine interface to assist user interactions with computer systems and communication with one other using human idiosyncrasies; a complete special effects and animation toolbox providing automatic lip synchronization without the normal constraints of head-sets, joysticks, and skilled animators; compression of video data to well below standard telecommunication channel bandwidth for video communications and multi-media systems; assisting speech training and aids for the handicapped; and facilitating player interaction for 'video gaming' and 'virtual worlds.' MARTI has introduced a new level of realism to man-machine interfacing and special effect animation which has been previously unseen.

  1. Computation of the Distribution of the Fiber-Matrix Interface Cracks in the Edge Trimming of CFRP

    NASA Astrophysics Data System (ADS)

    Wang, Fu-ji; Zhang, Bo-yu; Ma, Jian-wei; Bi, Guang-jian; Hu, Hai-bo

    2018-04-01

    Edge trimming is commonly used to bring the CFRP components to right dimension and shape in aerospace industries. However, various forms of undesirable machining damage occur frequently which will significantly decrease the material performance of CFRP. The damage is difficult to predict and control due to the complicated changing laws, causing unsatisfactory machining quality of CFRP components. Since the most of damage has the same essence: the fiber-matrix interface cracks, this study aims to calculate the distribution of them in edge trimming of CFRP, thereby to obtain the effects of the machining parameters, which could be helpful to guide the optimal selection of the machining parameters in engineering. Through the orthogonal cutting experiments, the quantitative relation between the fiber-matrix interface crack depth and the fiber cutting angle, cutting depth as well as cutting speed is established. According to the analysis on material removal process on any location of the workpiece in edge trimming, the instantaneous cutting parameters are calculated, and the formation process of the fiber-matrix interface crack is revealed. Finally, the computational method for the fiber-matrix interface cracks in edge trimming of CFRP is proposed. Upon the computational results, it is found that the fiber orientations of CFRP workpieces is the most significant factor on the fiber-matrix interface cracks, which can not only change the depth of them from micrometers to millimeters, but control the distribution image of them. Other machining parameters, only influence the fiber-matrix interface cracks depth but have little effect on the distribution image.

  2. Development of a Benthic Macroinvertebrate Multimetric Index (MMI) for Neotropical Savanna Headwater Streams

    EPA Science Inventory

    Assessing the ecological impacts of anthropogenic pressures is a key task in environmental management. Multimetric indices (MMIs), based on aquatic assemblage responses to anthropogenic pressures, have been used increasingly throughout the world. The MMI approach is a low-cost, r...

  3. Demonstration of an optical phased array using electro-optic polymer phase shifters

    NASA Astrophysics Data System (ADS)

    Hirano, Yoshikuni; Motoyama, Yasushi; Tanaka, Katsu; Machida, Kenji; Yamada, Toshiki; Otomo, Akira; Kikuchi, Hiroshi

    2018-03-01

    We have been investigating an optical phased array (OPA) using electro-optic (EO) polymers in phase shifters to achieve ultrafast optical beam steering. In this paper, we describe the basic structures of the OPA using EO polymer phase shifters and show the beam steering capability of the OPA. The designed OPA has a multimode interference (MMI) beam splitter and 8-channel polymer waveguides with EO polymer phase shifters. We compare 1 × 8 MMI and cascaded 1 × 2 MMI beam splitters numerically and experimentally, and then obtain uniform intensity outputs from the 1 × 8 beam splitter. We fabricate the EO polymer OPA with a 1 × 8 MMI beam splitter to prevent intensity dispersion due to radiation loss in bending waveguides. We also evaluate the optical beam steering capability of the fabricated OPA and found a 2.7° deflection of far-field patterns when applying a voltage difference of 25 V in adjacent phase shifters.

  4. The Calabrian Arc: three-dimensional modelling of the subduction interface.

    PubMed

    Maesano, Francesco E; Tiberti, Mara M; Basili, Roberto

    2017-08-21

    The Calabrian Arc is a one-of-a-kind subduction zone, featuring one of the shortest slab segments (<150 km), one of the thickest accretionary wedges, and one of the oldest oceanic crust in the world. Despite a convergence rate of up to 5 mm/y and well-known intraslab seismicity below 40 km, its shallow interface shows little signs of seismic activity. Nonetheless, it has been attributed as generating historical large earthquakes and tsunamis. To gain insights into this subduction zone, we first made a geological reconstruction of the shallower slab interface (<20 km) and its overlying accretionary wedge by interpreting a grid of 54 seismic reflection lines (8,658 km) with 438 intersections within an area of 10 5  km 2 . Then, we constrained a deeper portion of the slab surface (40-350 km) using the seismicity distribution. Finally, we interpolated the two parts to obtain a seamless 3D surface highlighting geometric details of the subduction interface, its lateral terminations and down-dip curvature, and a slab tear at 70-100 km depth. Our 3D slab model of the Calabrian Arc will contribute to understanding of the geodynamics of a cornerstone in the Mediterranean tectonic puzzle and estimates of seismic and tsunami hazards in the region.

  5. Seismic Intensity, PGA and PGV for the South Napa Earthquake, August 24, 2014

    NASA Astrophysics Data System (ADS)

    Chen, S.; Pickering, A.; Mooney, W. D.; Crewdson, E.

    2014-12-01

    Numerous studies have investigated the statistical relationship between Modified Mercalli Intensity (MMI) and peak ground acceleration (PGA) and peak ground velocity (PGV). The Mw 6.0 South Napa (California) earthquake of August 24, 2014 provides valuable data to examine these relationships for both urban and rural environments within northern California. The finite fault model (D. Dreger, 2014) indicates that the fault rupture propagated predominantly NNW and up-dip from a 11-km-deep hypocenter. The epicentral location was 8 km SSW of downtown Napa. Recorded PGA north of the epicenter is as high as 600 cm/s2 and PGV locally reaches 80 cm/s. Field studies by two teams of investigators were conducted on August 24-26 and September 8-11, 2014 to assign MMI values at 108 sites. The highest MMI values are strongly localized along the NNW-SSE rupture trend north of the epicenter. Parts of the city of Napa and some communities several km farther north on Dry Creek Road were found to have experienced shaking intensities of MMI VII to VIII. The observed effects include houses moved off their foundations, chimney collapse or damage, cracked foundations and/or interior walls, broken windows, and the lateral displacement of heavy furniture. Communities to the east and west of this zone of high seismic intensity reported significantly lower values of MMI, typically IV and V even at distances as close as 10 km from the mapped surface rupture. In comparison with previous estimates by Wald et al. (1999) and Dangkua and Cramer (2011), we find that MMI III-VIII uniformly correspond to significantly larger (>150%) PGA and PGV values, as reported by the Center for Engineering Strong Motion Data (2014). We attribute this observation to two primary factors: (1) improved earthquake engineering in the post-Loma Prieta earthquake era that has led to building construction, both new and retrofitted, that is more resistant to earthquake strong ground motions; and (2) a frequency band relevant to these MMI estimates that contains less energy than that leading to the PGA or PGV values. The latter would primarily be a source effect.

  6. Thyroid organotypic rat and human cultures used to investigate drug effects on thyroid function, hormone synthesis and release pathways.

    PubMed

    Vickers, Alison E M; Heale, Jason; Sinclair, John R; Morris, Stephen; Rowe, Josh M; Fisher, Robyn L

    2012-04-01

    Drug induced thyroid effects were evaluated in organotypic models utilizing either a rat thyroid lobe or human thyroid slices to compare rodent and human response. An inhibition of thyroid peroxidase (TPO) function led to a perturbation in the expression of key genes in thyroid hormone synthesis and release pathways. The clinically used thiourea drugs, methimazole (MMI) and 6-n-propyl-2-thioruacil (PTU), were used to evaluate thyroid drug response in these models. Inhibition of TPO occurred early as shown in rat thyroid lobes (2 h) and was sustained in both rat (24-48 h) and human (24 h) with ≥ 10 μM MMI. Thyroid from rats treated with single doses of MMI (30-1000 mg/kg) exhibited sustained TPO inhibition at 48 h. The MMI in vivo thyroid concentrations were comparable to the culture concentrations (~15-84 μM), thus demonstrating a close correlation between in vivo and ex vivo thyroid effects. A compensatory response to TPO inhibition was demonstrated in the rat thyroid lobe with significant up-regulation of genes involved in the pathway of thyroid hormone synthesis (Tpo, Dio1, Slc5a5, Tg, Tshr) and the megalin release pathway (Lrp2) by 24h with MMI (≥ 10 μM) and PTU (100 μM). Similarly, thyroid from the rat in vivo study exhibited an up-regulation of Dio1, Slc5a5, Lrp2, and Tshr. In human thyroid slices, there were few gene expression changes (Slc5a5, ~2-fold) and only at higher MMI concentrations (≥ 1500 μM, 24h). Extended exposure (48 h) resulted in up-regulation of Tpo, Dio1 and Lrp2, along with Slc5a5 and Tshr. In summary, TPO was inhibited by similar MMI concentrations in rat and human tissue, however an increased sensitivity to drug treatment in rat is indicated by the up-regulation of thyroid hormone synthesis and release gene pathways at concentrations found not to affect human tissue. Copyright © 2012 Elsevier Inc. All rights reserved.

  7. Research interface on a programmable ultrasound scanner.

    PubMed

    Shamdasani, Vijay; Bae, Unmin; Sikdar, Siddhartha; Yoo, Yang Mo; Karadayi, Kerem; Managuli, Ravi; Kim, Yongmin

    2008-07-01

    Commercial ultrasound machines in the past did not provide the ultrasound researchers access to raw ultrasound data. Lack of this ability has impeded evaluation and clinical testing of novel ultrasound algorithms and applications. Recently, we developed a flexible ultrasound back-end where all the processing for the conventional ultrasound modes, such as B, M, color flow and spectral Doppler, was performed in software. The back-end has been incorporated into a commercial ultrasound machine, the Hitachi HiVision 5500. The goal of this work is to develop an ultrasound research interface on the back-end for acquiring raw ultrasound data from the machine. The research interface has been designed as a software module on the ultrasound back-end. To increase the amount of raw ultrasound data that can be spooled in the limited memory available on the back-end, we have developed a method that can losslessly compress the ultrasound data in real time. The raw ultrasound data could be obtained in any conventional ultrasound mode, including duplex and triplex modes. Furthermore, use of the research interface does not decrease the frame rate or otherwise affect the clinical usability of the machine. The lossless compression of the ultrasound data in real time can increase the amount of data spooled by approximately 2.3 times, thus allowing more than 6s of raw ultrasound data to be acquired in all the modes. The interface has been used not only for early testing of new ideas with in vitro data from phantoms, but also for acquiring in vivo data for fine-tuning ultrasound applications and conducting clinical studies. We present several examples of how newer ultrasound applications, such as elastography, vibration imaging and 3D imaging, have benefited from this research interface. Since the research interface is entirely implemented in software, it can be deployed on existing HiVision 5500 ultrasound machines and may be easily upgraded in the future. The developed research interface can aid researchers in the rapid testing and clinical evaluation of new ultrasound algorithms and applications. Additionally, we believe that our approach would be applicable to designing research interfaces on other ultrasound machines.

  8. Long-wave infrared 1 × 2 MMI based on air-gap beneath silicon rib waveguides

    NASA Astrophysics Data System (ADS)

    Wei, Yuxin; Li, Guoyi; Hao, Yinlei; Li, Yubo; Yang, Jianyi; Wang, Minghua; Jiang, Xiaoqing

    2011-08-01

    The undercut long-wave infrared (LWIR) waveguide components with air-gap beneath are analyzed and fabricated on the Si-wafer with simple manufacturing process. A 1 × 2 multimode interference (MMI) splitter based on this structure is presented and measured under the 10.6μm wavelength experimental setup. The uniformity of the MMI fabricated is 0.76 dB. The relationship among the output power, slab thickness and air-gap width is also fully discussed. Furthermore, undercut straight waveguides based on SOI platform are fabricated for propagation loss evaluation. Ways to reduce the loss are discussed either.

  9. Passive athermalization of multimode interference devices for wavelength-locking applications.

    PubMed

    Ruiz-Perez, Victor I; May-Arrioja, Daniel A; Guzman-Sepulveda, Jose R

    2017-03-06

    In this paper we demonstrate the passive, material-based athermalization of all-fiber architectures by cascading multimode interference (MMI) devices. In-line thermal compensation is achieved by including a liquid-core multimode section of variable length that allows ensuring temperature-independent operation while preserving the inherent filter-like spectral response of the MMI devices. The design of the temperature compensation unit is straightforward and its fabrication is simple. The applicability of our approach is experimentally verified by fabricating a wavelength-locked MMI laser with sensitivity of only -0.1 pm/°C, which is at least one order of magnitude lower than that achieved with other fiber optics devices.

  10. The Talbot effect in a metamaterial

    NASA Astrophysics Data System (ADS)

    Nikkhah, H.; Hasan, M.; Hall, T. J.

    2018-02-01

    The effect of anisotropy and spatial dispersion of a metamaterial on the Talbot effect may be engineered in principle. This has profound implications for applications of the Talbot effect such as the design of a multimode interference coupler (MMI). The paper describes how a metamaterial can suppress the modal phase error which otherwise limits the scaling of MMI port dimension. A binary multilayer dielectric material described by the Kronig-Penney model is shown to provide a close approximation to the required dispersion relation. Results of simulations of a multi-slotted waveguide MMI engineered to provide a polarising beam splitter function are given as an example of the method.

  11. Fabrication of 8×8 MMI optical coupler in BK7 by ion-exchange

    NASA Astrophysics Data System (ADS)

    Li, Xia; Li, Xi-Hua; Zhou, Qiang; Jiang, Xiao-Qing; Yang, Jian-Yi; Wang, Ming-Hua

    2005-01-01

    The planar waveguide optical couplers are of prime importance in optical communication and optical signal processing system. Comparing with the optical fiber coupler (OFC) which fabricated by fused biconical taper technology, the planar waveguide couplers are more compact size, lower loss, better uniformity, easier manufacture and integration. Multimode interference (MMI) couplers have many advantages, such as compact size, wavelength and polarization insensitivity, fabrication tolerances and low loss, etc., which concentrate more and more attention. Conventional MMI devices are based on the uniform index waveguides. When the number of input/output waveguides becomes larger, the intrinsic propagation constant error, which will cause bad uniformity of output power, can"t be neglected. In fact, most waveguide devices are graded-index. With the enhanced compatibility of MMI coupler, the performance can be improved at the same time. Prior study shows that graded-index MMI couplers reach the best performance under certain index contrast. Among many available materials, glass is chosen to be the substrate of the coupler, because of its good features, such as low loss, ease fabrication, cheap cost, and so on. In this paper, an 8×8 MMI optical coupler is designed based on the principle of graded-index MMI. The coupler is composed of a waveguide, which is designed to support a large number of modes, and several access (usually single-mode) waveguides, which are used to launch light into and recover light from that multimode waveguide. The total length of the device is less than 3.5 centimeter, including S-bends which lead the multiple images to the output of the device with the spacing D=250μm to make the device fiber compatible. In this paper, we describe an experimental realization of the 8×8 graded-index MMI optical coupler and the measurement of its performance with the testing laser of the wavelength of 1.55μm. The device is fabricated by ion-exchange on BK7 glass substrate. During the ion-exchange process, a melting mixture of AgNO3 : (KNO3 : NaNO3) (molar ratio, 0.001:1) is used at 350~380°C for different times (range from 8 to 18 hours) to fabricate the coupler. The experimental results show that the performance of the optical coupler is quite promising. For instance, while launching light from No.5 waveguide, the uniformity of the device is approximately 0.72dB. Optimization of design and fabrication is going on to improve the total performance of the optical coupler.

  12. Experimental Characterization and Modeling of Thermal Contact Resistance of Electric Machine Stator-to-Cooling Jacket Interface Under Interference Fit Loading

    DOE PAGES

    Cousineau, Justine Emily; Bennion, Kevin S.; Chieduko, Victor; ...

    2018-05-08

    Cooling of electric machines is a key to increasing power density and improving reliability. This paper focuses on the design of a machine using a cooling jacket wrapped around the stator. The thermal contact resistance (TCR) between the electric machine stator and cooling jacket is a significant factor in overall performance and is not well characterized. This interface is typically an interference fit subject to compressive pressure exceeding 5 MPa. An experimental investigation of this interface was carried out using a thermal transmittance setup using pressures between 5 and 10 MPa. Furthermore, the results were compared to currently available modelsmore » for contact resistance, and one model was adapted for prediction of TCR in future motor designs.« less

  13. Experimental Characterization and Modeling of Thermal Contact Resistance of Electric Machine Stator-to-Cooling Jacket Interface Under Interference Fit Loading

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Cousineau, Justine Emily; Bennion, Kevin S.; Chieduko, Victor

    Cooling of electric machines is a key to increasing power density and improving reliability. This paper focuses on the design of a machine using a cooling jacket wrapped around the stator. The thermal contact resistance (TCR) between the electric machine stator and cooling jacket is a significant factor in overall performance and is not well characterized. This interface is typically an interference fit subject to compressive pressure exceeding 5 MPa. An experimental investigation of this interface was carried out using a thermal transmittance setup using pressures between 5 and 10 MPa. Furthermore, the results were compared to currently available modelsmore » for contact resistance, and one model was adapted for prediction of TCR in future motor designs.« less

  14. The desktop interface in intelligent tutoring systems

    NASA Technical Reports Server (NTRS)

    Baudendistel, Stephen; Hua, Grace

    1987-01-01

    The interface between an Intelligent Tutoring System (ITS) and the person being tutored is critical to the success of the learning process. If the interface to the ITS is confusing or non-supportive of the tutored domain, the effectiveness of the instruction will be diminished or lost entirely. Consequently, the interface to an ITS should be highly integrated with the domain to provide a robust and semantically rich learning environment. In building an ITS for ZetaLISP on a LISP Machine, a Desktop Interface was designed to support a programming learning environment. Using the bitmapped display, windows, and mouse, three desktops were designed to support self-study and tutoring of ZetaLISP. Through organization, well-defined boundaries, and domain support facilities, the desktops provide substantial flexibility and power for the student and facilitate learning ZetaLISP programming while screening the student from the complex LISP Machine environment. The student can concentrate on learning ZetaLISP programming and not on how to operate the interface or a LISP Machine.

  15. Real time software for a heat recovery steam generator control system

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Valdes, R.; Delgadillo, M.A.; Chavez, R.

    1995-12-31

    This paper is addressed to the development and successful implementation of a real time software for the Heat Recovery Steam Generator (HRSG) control system of a Combined Cycle Power Plant. The real time software for the HRSG control system physically resides in a Control and Acquisition System (SAC) which is a component of a distributed control system (DCS). The SAC is a programmable controller. The DCS installed at the Gomez Palacio power plant in Mexico accomplishes the functions of logic, analog and supervisory control. The DCS is based on microprocessors and the architecture consists of workstations operating as a Man-Machinemore » Interface (MMI), linked to SAC controllers by means of a communication system. The HRSG real time software is composed of an operating system, drivers, dedicated computer program and application computer programs. The operating system used for the development of this software was the MultiTasking Operating System (MTOS). The application software developed at IIE for the HRSG control system basically consisted of a set of digital algorithms for the regulation of the main process variables at the HRSG. By using the multitasking feature of MTOS, the algorithms are executed pseudo concurrently. In this way, the applications programs continuously use the resources of the operating system to perform their functions through a uniform service interface. The application software of the HRSG consist of three tasks, each of them has dedicated responsibilities. The drivers were developed for the handling of hardware resources of the SAC controller which in turn allows the signals acquisition and data communication with a MMI. The dedicated programs were developed for hardware diagnostics, task initializations, access to the data base and fault tolerance. The application software and the dedicated software for the HRSG control system was developed using C programming language due to compactness, portability and efficiency.« less

  16. MMI Preparatory School Computerized Model Library.

    ERIC Educational Resources Information Center

    Everhart, Nancy

    This booklet provides a detailed description of the computerization of the library of MMI Preparatory School, a private, non-sectarian college preparatory school in Pennsylvania for students in grades 7 through 12. Each of the following functions is investigated: (1) catalog card production; (2) online reference services; (3) circulation; (4) word…

  17. Hidden Item Variance in Multiple Mini-Interview Scores

    ERIC Educational Resources Information Center

    Zaidi, Nikki L.; Swoboda, Christopher M.; Kelcey, Benjamin M.; Manuel, R. Stephen

    2017-01-01

    The extant literature has largely ignored a potentially significant source of variance in multiple mini-interview (MMI) scores by "hiding" the variance attributable to the sample of attributes used on an evaluation form. This potential source of hidden variance can be defined as rating items, which typically comprise an MMI evaluation…

  18. Graphical user interfaces for symbol-oriented database visualization and interaction

    NASA Astrophysics Data System (ADS)

    Brinkschulte, Uwe; Siormanolakis, Marios; Vogelsang, Holger

    1997-04-01

    In this approach, two basic services designed for the engineering of computer based systems are combined: a symbol-oriented man-machine-service and a high speed database-service. The man-machine service is used to build graphical user interfaces (GUIs) for the database service; these interfaces are stored using the database service. The idea is to create a GUI-builder and a GUI-manager for the database service based upon the man-machine service using the concept of symbols. With user-definable and predefined symbols, database contents can be visualized and manipulated in a very flexible and intuitive way. Using the GUI-builder and GUI-manager, a user can build and operate its own graphical user interface for a given database according to its needs without writing a single line of code.

  19. Basin Wide Erosion and Soil Production Rates of a High Altitude Plateau in the Korean Peninsula Considered as an Uplifted Paleo Erosional Surface: Implications for Its Development Process and the Tectonics

    NASA Astrophysics Data System (ADS)

    Byun, J.; Seong, Y.

    2012-12-01

    The development process of High Altitude Plateaus (HAPs) has been a controversial issue in geomorphology. HAPs have been interpreted as uplifted erosional surfaces mainly controlled by fluvial processes. Recent studies, however, argued that the definition of the Paleo Erosional Surfaces (PESs) is ambiguous and HAPs, considered as the uplifted PESs, could be formed under various local lithologic, tectonic and climatic conditions. But these suggestions were severely limited by the lack of quantitative data in the field. Here, we investigate this issue of the development process of HAPs through estimating both basin wide erosion rates and soil production rates of the Daegwanryeong area in the Korean Peninsula (KP), where a HAP with low-relief hilly landscape is found. Study area has been known as a typical one of PESs in the KP, which have been uplifted since the early Miocene. Particularly deeply weathered saprolites, easily found in the study area, have also been believed to be resulted from the Tertiary deep weathering under higher temperature at the paleo sea level. First, analysis of 10Be in saprolite from the base of the soil column, except one under no soil mantle, shows that soil production rates decline linearly with increasing soil depth. These data provide a soil production function with a maximum soil production rate of 70.6m/m.y. under 24cm of soil and a minimum of 22m/m.y. under 75cm of soil. Accordingly it means that the interface between soil and saprolite have gone down maximum 141.2 m since the Quaternary. Thus it suggests that the saprolites are the results under current local climatic and geomorphic conditions rather than the relict of the Tertiary deep weathering. Second, measurements of 10Be in alluvial sediments show that the average erosion rate (70.7m/m.y.) of the study area is close to the maximum soil production rate, thus basin wide erosion rates of the study area are controlled by the current soil production rates. It means that about 1,400m has been eroded off since the early Miocene, when uplift of the KP seems to begin. Consequently it is difficult to think the HAP of the study area as the PES as well as one, which has been eroded keeping the original form of the PES. Furthermore, the erosion rates are lower than the uplift rates during the late Quaternary (about 300m/m.y.), but similar to the uplift rates before the early Miocene (about 100m/m.y.). Therefore, it suggests that the HAP of the study area has been uplifted since the early Miocene, but has not approached the steady state with the neotectonics of the KP. In summary, we suggest that the HAP of the study area is the result of the geomorphic process under current climatic and geomorphic condition rather than the relict of the PES.

  20. Human machine interface display design document.

    DOT National Transportation Integrated Search

    2008-01-01

    The purpose of this document is to describe the design for the human machine interface : (HMI) display for the Next Generation 9-1-1 (NG9-1-1) System (or system of systems) : based on the initial Tier 1 requirements identified for the NG9-1-1 S...

  1. Insect-machine interface based neurocybernetics.

    PubMed

    Bozkurt, Alper; Gilmour, Robert F; Sinha, Ayesa; Stern, David; Lal, Amit

    2009-06-01

    We present details of a novel bioelectric interface formed by placing microfabricated probes into insect during metamorphic growth cycles. The inserted microprobes emerge with the insect where the development of tissue around the electronics during the pupal development allows mechanically stable and electrically reliable structures coupled to the insect. Remarkably, the insects do not react adversely or otherwise to the inserted electronics in the pupae stage, as is true when the electrodes are inserted in adult stages. We report on the electrical and mechanical characteristics of this novel bioelectronic interface, which we believe would be adopted by many investigators trying to investigate biological behavior in insects with negligible or minimal traumatic effect encountered when probes are inserted in adult stages. This novel insect-machine interface also allows for hybrid insect-machine platforms for further studies. As an application, we demonstrate our first results toward navigation of flight in moths. When instrumented with equipment to gather information for environmental sensing, such insects potentially can assist man to monitor the ecosystems that we share with them for sustainability. The simplicity of the optimized surgical procedure we invented allows for batch insertions to the insect for automatic and mass production of such hybrid insect-machine platforms. Therefore, our bioelectronic interface and hybrid insect-machine platform enables multidisciplinary scientific and engineering studies not only to investigate the details of insect behavioral physiology but also to control it.

  2. Hybrid EEG-EOG brain-computer interface system for practical machine control.

    PubMed

    Punsawad, Yunyong; Wongsawat, Yodchanan; Parnichkun, Manukid

    2010-01-01

    Practical issues such as accuracy with various subjects, number of sensors, and time for training are important problems of existing brain-computer interface (BCI) systems. In this paper, we propose a hybrid framework for the BCI system that can make machine control more practical. The electrooculogram (EOG) is employed to control the machine in the left and right directions while the electroencephalogram (EEG) is employed to control the forword, no action, and complete stop motions of the machine. By using only 2-channel biosignals, the average classification accuracy of more than 95% can be achieved.

  3. Design Guidelines and Criteria for User/Operator Transactions with Battlefield Automated Systems. Volume 5. Background Literature

    DTIC Science & Technology

    1981-02-01

    the machine . ARI’s efforts in this area focus on human perfor- mance problems related to interactions with command and control centers, and on issues...improvement of the user- machine interface. Lacking consistent design principles, current practice results in a fragmented and unsystematic approach to system...complexity in the user- machine interface of BAS, ARI supported this effort for develop- me:nt of an online language for Army tactical intelligence

  4. 76 FR 75570 - Self-Regulatory Organizations; The Depository Trust Company; Notice of Filing of Proposed Rule...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-12-02

    ... counterparty by counterparty basis. Currently, all free money market instrument (``MMI'') deliveries are routed... was built in 1990 to route money market instrument (``MMI'') transactions for receiver approval. In... orders involve no securities, only money. \\5\\ The net debit cap control is designed so that DTC may...

  5. Development of a regional littoral benthic macroinvertebrate multi-metric index (MMI) for lakes from the National Lakes Assessment

    EPA Science Inventory

    During the 2007 National Lakes Assessment (NLA) benthic macroinvertebrate samples were collected from the lake littoral zone. The purpose of the sampling was to assess the feasibility of a multi-metric index (MMI) to assess the condition of the littoral benthic macroinvertebrate...

  6. Gasohol Quality Control for Real Time Applications by Means of a Multimode Interference Fiber Sensor

    PubMed Central

    Rodríguez Rodríguez, Adolfo J.; Baldovino-Pantaleón, Oscar; Domínguez Cruz, Rene F.; Zamarreño, Carlos R.; Matías, Ignacio R.; May-Arrioja, Daniel A.

    2014-01-01

    In this work we demonstrate efficient quality control of a variety of gasoline and ethanol (gasohol) blends using a multimode interference (MMI) fiber sensor. The operational principle relies on the fact that the addition of ethanol to the gasohol blend reduces the refractive index (RI) of the gasoline. Since MMI sensors are capable of detecting small RI changes, the ethanol content of the gasohol blend is easily determined by tracking the MMI peak wavelength response. Gasohol blends with ethanol contents ranging from 0% to 50% has been clearly identified using this device, which provides a linear response with a maximum sensitivity of 0.270 nm/% EtOH. The sensor can also distinguish when water incorporated in the blend has exceeded the maximum volume tolerated by the gasohol blend, which is responsible for phase separation of the ethanol and gasoline and could cause serious engine failures. Since the MMI sensor is straightforward to fabricate and does not require any special coating it is a cost effective solution for real time and in-situ monitoring of the quality of gasohol blends. PMID:25256111

  7. Numerical analysis of a 3D optical sensor based on single mode fiber to multimode interference graphene design

    NASA Astrophysics Data System (ADS)

    Mutter, Kussay N.; Jafri, Zubir M.; Tan, Kok Chooi

    2016-04-01

    In this paper, the simulation and design of a waveguide for water turbidity sensing are presented. The structure of the proposed sensor uses a 2x2 array of multimode interference (MMI) coupler based on micro graphene waveguide for high sensitivity. The beam propagation method (BPM) are used to efficiently design the sensor structure. The structure is consist of an array of two by two elements of sensors. Each element has three sections of single mode for field input tapered to MMI as the main core sensor without cladding which is graphene based material, and then a single mode fiber as an output. In this configuration MMI responses to any change in the environment. We validate and present the results by implementing the design on a set of sucrose solution and showing how these samples lead to a sensitivity change in the sensor based on the MMI structures. Overall results, the 3D design has a feasible and effective sensing by drawing topographical distribution of suspended particles in the water.

  8. Genomic organization, evolution and functional characterization of soluble toll-like receptor 5 (TLR5S) in miiuy croaker (Miichthys miiuy).

    PubMed

    Huo, Ruixuan; Zhao, Xueyan; Han, Jingjing; Xu, Tianjun

    2018-05-30

    Toll-like receptors (TLRs) play the key role in host defense of invasion of pathogens, not only in the innate immunity, but also in adaptive immunity. There are significant varieties and distinct features in fish TLRs, the TLR5 subfamily have two members (TLR5M and TLR5S). However, the exact role of TLR5 was lack of research in fish. In this study, a soluble form of TLR5 (TLR5S) was identified in miiuy croaker. The bioinformatics analysis showed that miiuy croaker TLR5S lacked the transmembrane domain and TIR domain. In other words, mmiTLR5S only has leucine-rich repeats (LRRs) domain, it is one of differences between TLR5M and TLR5S. Comparative genomic analysis showed that TLR5S might have happened an evolution between species. Expression analysis showed that mmiTLR5S was expressed in all tested miiuy croaker tissues and the mmiTLR5S expressions were significantly upregulated at 12 h in liver and kidney after Vibrio harveyi infection. Further functional experiments showed that NF-кB can be actived by mmiTLR5S, TLR5S might be an indispensable role in organism immune response. In short, the study of mmiTLR5S enriches the information of TLR5S and lays the foundation for future research on teleost TLRs system. Copyright © 2018 Elsevier Ltd. All rights reserved.

  9. Developmental exposure to methimazole increases anxiety behavior in zebrafish.

    PubMed

    Reider, Masha; Connaughton, Victoria P

    2015-10-01

    The role of thyroid hormones in vertebrate development has been well documented for several decades. As hypothyroidism during critical periods of development can cause defects to the development of every major organ system, including brain, eye, and general morphology, we hypothesized that hypothyroidism would affect specific behaviors. To assess this, we treated zebrafish with the hypothyroid drug methimazole (MMI) and examined changes in anxiety, shoaling, vision, and locomotion. Following low-dose MMI exposure for the first 10 days of life, a time of rapid and significant development, larvae were removed from treatment and allowed to develop until 1 month of age. Comparisons between treated and controls took place between 10 and 30 days postfertilization to examine times both during and after treatment. Using the novel tank and startle response tests, we found that anxiety behaviors are significantly increased following MMI treatment. These effects persisted for several days following removal from treatment and indicate a prolonged effect of early hypothyroidism. However, permanent MMI effects on anxiety were not observed, as anxiety behaviors of early treated zebrafish recovered to control levels following 10 days out of treatment. In contrast to the strong link between MMI treatment and anxiety, shoaling and visual behaviors were not significantly affected within our experimental parameters. This indicates that disruption of thyroid system functioning early in life can differentially affect behavior by specifically altering anxiety responses without producing indiscriminate changes to overall behavioral development. (c) 2015 APA, all rights reserved).

  10. Developing and piloting the multiple mini-interview in pre-registration student midwife selection in a UK setting.

    PubMed

    Callwood, Alison; Cooke, Debbie; Allan, Helen

    2014-12-01

    Published research has demonstrated that the multiple mini-interview (MMI) is a reliable assessment instrument in medical and nursing student selection. There is a dearth of evidence specifically relating to the advancement and subsequent evaluation of MMIs in the context of student midwife selection. To develop, pilot and examine the reliability of MMIs in pre-registration student midwife selection in a UK setting. DeVellis' framework for questionnaire development underpinned the generation of MMI scenarios. BSc (Hons) Midwifery Studies students at a Higher Education Institution in the UK volunteered to participate in 'mock' MMI circuits during the first week of their programme. An eight station model was piloted. Communication skills were rated at each station as a generic attribute. Station specific attributes assessed included: compassion and empathy; respect for difference and diversity; honesty and integrity; intellectual curiosity and reflective nature; advocacy; respect for privacy and dignity; team working and initiative; the role of the midwife and motivation to become a midwife. Participants' responses to scenario questions were rated on a 7 point scale. Cronbach's alpha scores measuring internal consistency ranged from 0.91 to 0.97 CONCLUSION: The systematic development of the MMI model and scenarios resulted in 'excellent' reliability across all stations. These findings endorse the MMI technique as a reliable alternative to the personal interview in informing final decisions in pre-registration student midwife selection. Copyright © 2014 Elsevier Ltd. All rights reserved.

  11. Probabilistic Relationships between Ground‐Motion Parameters and Modified Mercalli Intensity in California

    USGS Publications Warehouse

    Worden, C.B.; Wald, David J.; Rhoades, D.A.

    2012-01-01

    We use a database of approximately 200,000 modified Mercalli intensity (MMI) observations of California earthquakes collected from USGS "Did You Feel It?" (DYFI) reports, along with a comparable number of peak ground-motion amplitudes from California seismic networks, to develop probabilistic relationships between MMI and peak ground velocity (PGV), peak ground acceleration (PGA), and 0.3-s, 1-s, and 3-s 5% damped pseudospectral acceleration (PSA). After associating each ground-motion observation with an MMI computed from all the DYFI responses within 2 km of the observation, we derived a joint probability distribution between MMI and ground motion. We then derived reversible relationships between MMI and each ground-motion parameter by using a total least squares regression to fit a bilinear function to the median of the stacked probability distributions. Among the relationships, the fit to peak ground velocity has the smallest errors, though linear combinations of PGA and PGV give nominally better results. We also find that magnitude and distance terms reduce the overall residuals and are justifiable on an information theoretic basis. For intensities MMI≥5, our results are in close agreement with the relations of Wald, Quitoriano, Heaton, and Kanamori (1999); for lower intensities, our results fall midway between Wald, Quitoriano, Heaton, and Kanamori (1999) and those of Atkinson and Kaka (2007). The earthquakes in the study ranged in magnitude from 3.0 to 7.3, and the distances ranged from less than a kilometer to about 400 km from the source.

  12. Treatment of graves' disease with antithyroid drugs in the first trimester of pregnancy and the prevalence of congenital malformation.

    PubMed

    Yoshihara, Ai; Noh, JaedukYoshimura; Yamaguchi, Takuhiro; Ohye, Hidemi; Sato, Shiori; Sekiya, Kenichi; Kosuga, Yuka; Suzuki, Miho; Matsumoto, Masako; Kunii, Yo; Watanabe, Natsuko; Mukasa, Koji; Ito, Kunihiko; Ito, Koichi

    2012-07-01

    Several reports have suggested that propylthiouracil (PTU) may be safer than methimazole (MMI) for treating thyrotoxicosis during pregnancy because congenital malformations have been associated with the use of MMI during pregnancy. We investigated whether in utero exposure to antithyroid drugs resulted in a higher rate of major malformations than among the infants born to a control group of pregnant women. We reviewed the cases of women with Graves' disease who became pregnant. The pregnancy outcomes of 6744 women were known, and there were 5967 live births. MMI alone had been used to treat 1426 of the women, and 1578 women had been treated with PTU alone. The 2065 women who had received no medication for the treatment of Graves' disease during the first trimester served as the control group. The remaining women had been treated with potassium iodide, levothyroxine, or more than one drug during the first trimester. The antithyroid drugs were evaluated for associations with congenital malformations. The overall rate of major anomalies in the MMI group was 4.1% (50 of 1231), and it was significantly higher than the 2.1% (40 of 1906) in the control group (P = 0.002), but there was no increase in the overall rate of major anomalies in the PTU group in comparison with the control group (1.9%; 21 of 1399; P = 0.709). Seven of the 1231 newborns in the MMI group had aplasia cutis congenita, six had an omphalocele, seven had a symptomatic omphalomesenteric duct anomaly, and one had esophageal atresia. Hyperthyroidism in the first trimester of pregnancy did not increase the rate of congenital malformation. In utero exposure to MMI during the first trimester of pregnancy increased the rate of congenital malformations, and it significantly increased the rate of aplasia cutis congenita, omphalocele, and a symptomatic omphalomesenteric duct anomaly.

  13. Novel Application of Quantitative Single-Photon Emission Computed Tomography/Computed Tomography to Predict Early Response to Methimazole in Graves' Disease

    PubMed Central

    Kim, Hyun Joo; Bang, Ji-In; Kim, Ji-Young; Moon, Jae Hoon; So, Young

    2017-01-01

    Objective Since Graves' disease (GD) is resistant to antithyroid drugs (ATDs), an accurate quantitative thyroid function measurement is required for the prediction of early responses to ATD. Quantitative parameters derived from the novel technology, single-photon emission computed tomography/computed tomography (SPECT/CT), were investigated for the prediction of achievement of euthyroidism after methimazole (MMI) treatment in GD. Materials and Methods A total of 36 GD patients (10 males, 26 females; mean age, 45.3 ± 13.8 years) were enrolled for this study, from April 2015 to January 2016. They underwent quantitative thyroid SPECT/CT 20 minutes post-injection of 99mTc-pertechnetate (5 mCi). Association between the time to biochemical euthyroidism after MMI treatment and %uptake, standardized uptake value (SUV), functional thyroid mass (SUVmean × thyroid volume) from the SPECT/CT, and clinical/biochemical variables, were investigated. Results GD patients had a significantly greater %uptake (6.9 ± 6.4%) than historical control euthyroid patients (n = 20, 0.8 ± 0.5%, p < 0.001) from the same quantitative SPECT/CT protocol. Euthyroidism was achieved in 14 patients at 156 ± 62 days post-MMI treatment, but 22 patients had still not achieved euthyroidism by the last follow-up time-point (208 ± 80 days). In the univariate Cox regression analysis, the initial MMI dose (p = 0.014), %uptake (p = 0.015), and functional thyroid mass (p = 0.016) were significant predictors of euthyroidism in response to MMI treatment. However, only %uptake remained significant in a multivariate Cox regression analysis (p = 0.034). A %uptake cutoff of 5.0% dichotomized the faster responding versus the slower responding GD patients (p = 0.006). Conclusion A novel parameter of thyroid %uptake from quantitative SPECT/CT is a predictive indicator of an early response to MMI in GD patients. PMID:28458607

  14. Accounting for regional variation in both natural environment and human disturbance to improve performance of multimetric indices of lotic benthic diatoms.

    PubMed

    Tang, Tao; Stevenson, R Jan; Infante, Dana M

    2016-10-15

    Regional variation in both natural environment and human disturbance can influence performance of ecological assessments. In this study we calculated 5 types of benthic diatom multimetric indices (MMIs) with 3 different approaches to account for variation in ecological assessments. We used: site groups defined by ecoregions or diatom typologies; the same or different sets of metrics among site groups; and unmodeled or modeled MMIs, where models accounted for natural variation in metrics within site groups by calculating an expected reference condition for each metric and each site. We used data from the USEPA's National Rivers and Streams Assessment to calculate the MMIs and evaluate changes in MMI performance. MMI performance was evaluated with indices of precision, bias, responsiveness, sensitivity and relevancy which were respectively measured as MMI variation among reference sites, effects of natural variables on MMIs, difference between MMIs at reference and highly disturbed sites, percent of highly disturbed sites properly classified, and relation of MMIs to human disturbance and stressors. All 5 types of MMIs showed considerable discrimination ability. Using different metrics among ecoregions sometimes reduced precision, but it consistently increased responsiveness, sensitivity, and relevancy. Site specific metric modeling reduced bias and increased responsiveness. Combined use of different metrics among site groups and site specific modeling significantly improved MMI performance irrespective of site grouping approach. Compared to ecoregion site classification, grouping sites based on diatom typologies improved precision, but did not improve overall performance of MMIs if we accounted for natural variation in metrics with site specific models. We conclude that using different metrics among ecoregions and site specific metric modeling improve MMI performance, particularly when used together. Applications of these MMI approaches in ecological assessments introduced a tradeoff with assessment consistency when metrics differed across site groups, but they justified the convenient and consistent use of ecoregions. Copyright © 2016 Elsevier B.V. All rights reserved.

  15. Macroseismic Intensity and Instrumental Ground Motion Parameter Correlations for Central Mexico

    NASA Astrophysics Data System (ADS)

    Sandoval Gómez, H.; Ramirez Guzman, L.; Espindola, V.

    2012-12-01

    We present instrumental intensity prediction equations for earthquakes in Central Mexico based on the correlation of observed Instrumental Ground-Motion Parameters (IGMP) and Modified Mercalli Intensity (MMI) scale reports. The goal of this study is to provide a model that can be used by the near real-time earthquake response system operated by the Institutes of Engineering and Geophysics at the National Autonomous University of Mexico (UNAM), which delivers estimates of key information associated with the societal impact due to earthquakes not available in the immediate aftermath of the event. Correlations of MMI and IGMP have been derived in other countries with different tectonic settings and built environments, but this is the first study devoted to the development of equations for the central region of Mexico. The IGMP are obtained from records of several stations for earthquakes with Mw 5.0-8.0 from the seismic networks operated by UNAM and other institutions in Mexico. The MMI observations were primarily obtained from the Did You Feel It (DYFI) report service of the U.S. Geological Survey and re-interpreted MMI reports from UNAM earthquake bulletin archives. For each instrumental observation we assigned a mean MMI intensity based on the proximity of the site where reported value are available, constrained by geological conditions and a visual inspection to guarantee that the intensity would be within one unit of the assigned value; following the procedure by Atkinson and Kaka (2006). We derived correlations for peak ground velocity (pgv) and acceleration, and three spectral acceleration periods (T=1, 2 and 3 s). In addition, we analyzed the Mw and distance dependence. We concluded that pgv and the spectral accelerations are the most useful IGMP predictors for MMI in the region of interest and the correlations differ significantly from those obtained in regions with other tectonic settings and infrastructure vulnerabilities (e.g. Wald et al, 1999; Atkinson and Kaka, 2006, Cramer and Dangkua, 2011).

  16. Development of the FITS tools package for multiple software environments

    NASA Technical Reports Server (NTRS)

    Pence, W. D.; Blackburn, J. K.

    1992-01-01

    The HEASARC is developing a package of general purpose software for analyzing data files in FITS format. This paper describes the design philosophy which makes the software both machine-independent (it runs on VAXs, Suns, and DEC-stations) and software environment-independent. Currently the software can be compiled and linked to produce IRAF tasks, or alternatively, the same source code can be used to generate stand-alone tasks using one of two implementations of a user-parameter interface library. The machine independence of the software is achieved by writing the source code in ANSI standard Fortran or C, using the machine-independent FITSIO subroutine interface for all data file I/O, and using a standard user-parameter subroutine interface for all user I/O. The latter interface is based on the Fortran IRAF Parameter File interface developed at STScI. The IRAF tasks are built by linking to the IRAF implementation of this parameter interface library. Two other implementations of this parameter interface library, which have no IRAF dependencies, are now available which can be used to generate stand-alone executable tasks. These stand-alone tasks can simply be executed from the machine operating system prompt either by supplying all the task parameters on the command line or by entering the task name after which the user will be prompted for any required parameters. A first release of this FTOOLS package is now publicly available. The currently available tasks are described, along with instructions on how to obtain a copy of the software.

  17. All printed touchless human-machine interface based on only five functional materials

    NASA Astrophysics Data System (ADS)

    Scheipl, G.; Zirkl, M.; Sawatdee, A.; Helbig, U.; Krause, M.; Kraker, E.; Andersson Ersman, P.; Nilsson, D.; Platt, D.; Bodö, P.; Bauer, S.; Domann, G.; Mogessie, A.; Hartmann, Paul; Stadlober, B.

    2012-02-01

    We demonstrate the printing of a complex smart integrated system using only five functional inks: the fluoropolymer P(VDF:TrFE) (Poly(vinylidene fluoride trifluoroethylene) sensor ink, the conductive polymer PEDOT:PSS (poly(3,4 ethylenedioxythiophene):poly(styrene sulfonic acid) ink, a conductive carbon paste, a polymeric electrolyte and SU8 for separation. The result is a touchless human-machine interface, including piezo- and pyroelectric sensor pixels (sensitive to pressure changes and impinging infrared light), transistors for impedance matching and signal conditioning, and an electrochromic display. Applications may not only emerge in human-machine interfaces, but also in transient temperature or pressure sensing used in safety technology, in artificial skins and in disposable sensor labels.

  18. The MMI Device Ontology: Enabling Sensor Integration

    NASA Astrophysics Data System (ADS)

    Rueda, C.; Galbraith, N.; Morris, R. A.; Bermudez, L. E.; Graybeal, J.; Arko, R. A.; Mmi Device Ontology Working Group

    2010-12-01

    The Marine Metadata Interoperability (MMI) project has developed an ontology for devices to describe sensors and sensor networks. This ontology is implemented in the W3C Web Ontology Language (OWL) and provides an extensible conceptual model and controlled vocabularies for describing heterogeneous instrument types, with different data characteristics, and their attributes. It can help users populate metadata records for sensors; associate devices with their platforms, deployments, measurement capabilities and restrictions; aid in discovery of sensor data, both historic and real-time; and improve the interoperability of observational oceanographic data sets. We developed the MMI Device Ontology following a community-based approach. By building on and integrating other models and ontologies from related disciplines, we sought to facilitate semantic interoperability while avoiding duplication. Key concepts and insights from various communities, including the Open Geospatial Consortium (eg., SensorML and Observations and Measurements specifications), Semantic Web for Earth and Environmental Terminology (SWEET), and W3C Semantic Sensor Network Incubator Group, have significantly enriched the development of the ontology. Individuals ranging from instrument designers, science data producers and consumers to ontology specialists and other technologists contributed to the work. Applications of the MMI Device Ontology are underway for several community use cases. These include vessel-mounted multibeam mapping sonars for the Rolling Deck to Repository (R2R) program and description of diverse instruments on deepwater Ocean Reference Stations for the OceanSITES program. These trials involve creation of records completely describing instruments, either by individual instances or by manufacturer and model. Individual terms in the MMI Device Ontology can be referenced with their corresponding Uniform Resource Identifiers (URIs) in sensor-related metadata specifications (e.g., SensorML, NetCDF). These identifiers can be resolved through a web browser, or other client applications via HTTP against the MMI Ontology Registry and Repository (ORR), where the ontology is maintained. SPARQL-based query capabilities, which are enhanced with reasoning, along with several supported output formats, allow the effective interaction of diverse client applications with the semantic information associated with the device ontology. In this presentation we describe the process for the development of the MMI Device Ontology and illustrate extensions and applications that demonstrate the benefits of adopting this semantic approach, including example queries involving inference. We also highlight the issues encountered and future work.

  19. A Thyroid Hormone Challenge in Hypothyroid Rats Identifies T3 Regulated Genes in the Hypothalamus and in Models with Altered Energy Balance and Glucose Homeostasis

    PubMed Central

    Herwig, Annika; Campbell, Gill; Mayer, Claus-Dieter; Boelen, Anita; Anderson, Richard A.; Ross, Alexander W.; Mercer, Julian G.

    2014-01-01

    Background: The thyroid hormone triiodothyronine (T3) is known to affect energy balance. Recent evidence points to an action of T3 in the hypothalamus, a key area of the brain involved in energy homeostasis, but the components and mechanisms are far from understood. The aim of this study was to identify components in the hypothalamus that may be involved in the action of T3 on energy balance regulatory mechanisms. Methods: Sprague Dawley rats were made hypothyroid by giving 0.025% methimazole (MMI) in their drinking water for 22 days. On day 21, half the MMI-treated rats received a saline injection, whereas the others were injected with T3. Food intake and body weight measurements were taken daily. Body composition was determined by magnetic resonance imaging, gene expression was analyzed by in situ hybridization, and T3-induced gene expression was determined by microarray analysis of MMI-treated compared to MMI-T3-injected hypothalamic RNA. Results: Post mortem serum thyroid hormone levels showed that MMI treatment decreased circulating thyroid hormones and increased thyrotropin (TSH). MMI treatment decreased food intake and body weight. Body composition analysis revealed reduced lean and fat mass in thyroidectomized rats from day 14 of the experiment. MMI treatment caused a decrease in circulating triglyceride concentrations, an increase in nonesterified fatty acids, and decreased insulin levels. A glucose tolerance test showed impaired glucose clearance in the thyroidectomized animals. In the brain, in situ hybridization revealed marked changes in gene expression, including genes such as Mct8, a thyroid hormone transporter, and Agrp, a key component in energy balance regulation. Microarray analysis revealed 110 genes to be up- or downregulated with T3 treatment (±1.3-fold change, p<0.05). Three genes chosen from the differentially expressed genes were verified by in situ hybridization to be activated by T3 in cells located at or close to the hypothalamic ventricular ependymal layer and differentially expressed in animal models of long- and short-term body weight regulation. Conclusion: This study identified genes regulated by T3 in the hypothalamus, a key area of the brain involved in homeostasis and neuroendocrine functions. These include genes hitherto not known to be regulated by thyroid status. PMID:25087834

  20. Human-Automation Interaction Design for Adaptive Cruise Control Systems of Ground Vehicles.

    PubMed

    Eom, Hwisoo; Lee, Sang Hun

    2015-06-12

    A majority of recently developed advanced vehicles have been equipped with various automated driver assistance systems, such as adaptive cruise control (ACC) and lane keeping assistance systems. ACC systems have several operational modes, and drivers can be unaware of the mode in which they are operating. Because mode confusion is a significant human error factor that contributes to traffic accidents, it is necessary to develop user interfaces for ACC systems that can reduce mode confusion. To meet this requirement, this paper presents a new human-automation interaction design methodology in which the compatibility of the machine and interface models is determined using the proposed criteria, and if the models are incompatible, one or both of the models is/are modified to make them compatible. To investigate the effectiveness of our methodology, we designed two new interfaces by separately modifying the machine model and the interface model and then performed driver-in-the-loop experiments. The results showed that modifying the machine model provides a more compact, acceptable, effective, and safe interface than modifying the interface model.

  1. Human-Automation Interaction Design for Adaptive Cruise Control Systems of Ground Vehicles

    PubMed Central

    Eom, Hwisoo; Lee, Sang Hun

    2015-01-01

    A majority of recently developed advanced vehicles have been equipped with various automated driver assistance systems, such as adaptive cruise control (ACC) and lane keeping assistance systems. ACC systems have several operational modes, and drivers can be unaware of the mode in which they are operating. Because mode confusion is a significant human error factor that contributes to traffic accidents, it is necessary to develop user interfaces for ACC systems that can reduce mode confusion. To meet this requirement, this paper presents a new human-automation interaction design methodology in which the compatibility of the machine and interface models is determined using the proposed criteria, and if the models are incompatible, one or both of the models is/are modified to make them compatible. To investigate the effectiveness of our methodology, we designed two new interfaces by separately modifying the machine model and the interface model and then performed driver-in-the-loop experiments. The results showed that modifying the machine model provides a more compact, acceptable, effective, and safe interface than modifying the interface model. PMID:26076406

  2. Monitoring of seafloor crustal deformation using GPS/Acoustic technique along the Nankai Trough, Japan

    NASA Astrophysics Data System (ADS)

    Yasuda, K.; Tadokoro, K.; Ikuta, R.; Watanabe, T.; Fujii, C.; Matsuhiro, K.; Sayanagi, K.

    2014-12-01

    Seafloor crustal deformation is crucial for estimating the interplate locking at the shallow subduction zone and has been carried out at subduction margins in Japan, e.g., Japan Trench and Nankai Trough [Sato et al., 2011; Tadokoro et al., 2012]. Iinuma et al. [2012] derived slip distributions during the 2011 Tohoku-Oki earthquake using GPS/Acoustic data and on-land GPS data. The result showed that maximum slip is more than 85 m near the trench axis. The focal area along the Nankai trough extended to the trough axis affected this earthquake by cabinet office, government of Japan.  We monitored seafloor crustal deformation along the Nankai trough, Japan. Observation regions are at the eastern end of Nankai trough (named Suruga trough) and at the central Nankai trough. We established and monitored by two sites across the trough at each region. In the Suruga trough region, we repeatedly observed from 2005 to 2013. We observed 13 and 14 times at a foot wall side (SNE) and at a hanging wall side (SNW), respectively. We estimated the displacement velocities with relative to the Amurian plate from the result of repeated observation. The estimated displacement velocity vectors at SNE and SNW are 42±8 mm/y to N94±3˚W direction and 39±11 mm/y to N84±9˚W direction, respectively. The directions are the same as those measured at the on-land GPS stations. The magnitudes of velocity vector indicate significant shortening by approximately 4 mm/y between SNW and on-land GPS stations at hanging wall side of the Suruga Trough. This result shows that the plate interface at the northernmost Suruga trough is strongly locked. In the central Nankai trough region, we established new two stations across the central Nankai trough (Both stations are about 15km distance from trough) and observed only three times, August 2013, January 2014, and June 2014. We report the results of monitoring performed in this year.

  3. Assisted navigation based on shared-control, using discrete and sparse human-machine interfaces.

    PubMed

    Lopes, Ana C; Nunes, Urbano; Vaz, Luis; Vaz, Luís

    2010-01-01

    This paper presents a shared-control approach for Assistive Mobile Robots (AMR), which depends on the user's ability to navigate a semi-autonomous powered wheelchair, using a sparse and discrete human-machine interface (HMI). This system is primarily intended to help users with severe motor disabilities that prevent them to use standard human-machine interfaces. Scanning interfaces and Brain Computer Interfaces (BCI), characterized to provide a small set of commands issued sparsely, are possible HMIs. This shared-control approach is intended to be applied in an Assisted Navigation Training Framework (ANTF) that is used to train users' ability in steering a powered wheelchair in an appropriate manner, given the restrictions imposed by their limited motor capabilities. A shared-controller based on user characterization, is proposed. This controller is able to share the information provided by the local motion planning level with the commands issued sparsely by the user. Simulation results of the proposed shared-control method, are presented.

  4. Redesigning the Human-Machine Interface for Computer-Mediated Visual Technologies.

    ERIC Educational Resources Information Center

    Acker, Stephen R.

    1986-01-01

    This study examined an application of a human machine interface which relies on the use of optical bar codes incorporated in a computer-based module to teach radio production. The sequencing procedure used establishes the user rather than the computer as the locus of control for the mediated instruction. (Author/MBR)

  5. Robotic devices and brain-machine interfaces for hand rehabilitation post-stroke.

    PubMed

    McConnell, Alistair C; Moioli, Renan C; Brasil, Fabricio L; Vallejo, Marta; Corne, David W; Vargas, Patricia A; Stokes, Adam A

    2017-06-28

    To review the state of the art of robotic-aided hand physiotherapy for post-stroke rehabilitation, including the use of brain-machine interfaces. Each patient has a unique clinical history and, in response to personalized treatment needs, research into individualized and at-home treatment options has expanded rapidly in recent years. This has resulted in the development of many devices and design strategies for use in stroke rehabilitation. The development progression of robotic-aided hand physiotherapy devices and brain-machine interface systems is outlined, focussing on those with mechanisms and control strategies designed to improve recovery outcomes of the hand post-stroke. A total of 110 commercial and non-commercial hand and wrist devices, spanning the 2 major core designs: end-effector and exoskeleton are reviewed. The growing body of evidence on the efficacy and relevance of incorporating brain-machine interfaces in stroke rehabilitation is summarized. The challenges involved in integrating robotic rehabilitation into the healthcare system are discussed. This review provides novel insights into the use of robotics in physiotherapy practice, and may help system designers to develop new devices.

  6. Adapting human-machine interfaces to user performance.

    PubMed

    Danziger, Zachary; Fishbach, Alon; Mussa-Ivaldi, Ferdinando A

    2008-01-01

    The goal of this study was to create and examine machine learning algorithms that adapt in a controlled and cadenced way to foster a harmonious learning environment between the user of a human-machine interface and the controlled device. In this experiment, subjects' high-dimensional finger motions remotely controlled the joint angles of a simulated planar 2-link arm, which was used to hit targets on a computer screen. Subjects were required to move the cursor at the endpoint of the simulated arm.

  7. Proceedings of the 1986 IEEE international conference on systems, man and cybernetics

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Not Available

    1986-01-01

    This book presents the papers given at a conference on man-machine systems. Topics considered at the conference included neural model-based cognitive theory and engineering, user interfaces, adaptive and learning systems, human interaction with robotics, decision making, the testing and evaluation of expert systems, software development, international conflict resolution, intelligent interfaces, automation in man-machine system design aiding, knowledge acquisition in expert systems, advanced architectures for artificial intelligence, pattern recognition, knowledge bases, and machine vision.

  8. Man-machine interface for the control of a lunar transport machine

    NASA Technical Reports Server (NTRS)

    Ashley, Richard; Bacon, Loring; Carlton, Scott Tim; May, Mark; Moore, Jimmy; Peek, Dennis

    1987-01-01

    A proposed first generation human interface control panel is described which will be used to control SKITTER, a three-legged lunar walking machine. Under development at Georgia Tech, SKITTER will be a multi-purpose, un-manned vehicle capable of preparing a site for the proposed lunar base in advance of the arrival of men. This walking machine will be able to accept modular special purpose tools, such as a crane, a core sampling drill, and a digging device, among others. The project was concerned with the design of a human interface which could be used, from earth, to control the movements of SKITTER on the lunar surface. Preliminary inquiries were also made into necessary modifications required to adapt the panel to both a shirt-sleeve lunar environment and to a mobile unit which could be used by a man in a space suit at a lunar work site.

  9. Psychometric Properties of the Multiple Mini-Interview Used for Medical Admissions: Findings from Generalizability and Rasch Analyses

    ERIC Educational Resources Information Center

    Sebok, Stefanie S.; Luu, King; Klinger, Don A.

    2014-01-01

    The multiple mini-interview (MMI) has become an increasingly popular admissions method for selecting prospective students into professional programs (e.g., medical school). The MMI uses a series of short, labour intensive simulation stations and scenario interviews to more effectively assess applicants' non-cognitive qualities such as…

  10. 77 FR 17534 - Self-Regulatory Organizations; The Depository Trust Company; Notice of Filing of Proposed Rule...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-03-26

    ... Association (``SIFMA'') formed the MMI Blue-Sky Task Force (``Task Force'') to address systemic and unique... processing. The Task Force, along other money market industry members,\\8\\ determined that DTC's current MMI... amount or proceeds after the 3 p.m. E.T. deadline for RTP instructions.\\9\\ Accordingly, DTC is proposing...

  11. Monitoring Molecules in Neuroscience Then and Now

    PubMed Central

    Rice, Margaret E.

    2017-01-01

    The 16th International Conference on Monitoring Molecules in Neuroscience (MMiN) was held in Gothenburg, Sweden in late spring 2016. This conference originated as a methods meeting focused on in vivo voltammetric techniques and microdialysis. Over time, however, the scope has evolved to include a number of other methods for neurochemical detection that range from single-cell fluorescence in vitro and in vivo in animal models to whole-brain imaging in humans. Overall, MMiN provides a unique forum for introducing new developments in neurochemical detection, as well as for reporting exciting neurobiological insights provided by established and novel methods. This Viewpoint includes a brief history of the meeting, factors that have contributed its evolution, and some highlights of MMiN 2016. PMID:28169519

  12. Monitoring Molecules in Neuroscience Then and Now.

    PubMed

    Rice, Margaret E

    2017-02-15

    The 16th International Conference on Monitoring Molecules in Neuroscience (MMiN) was held in Gothenburg, Sweden in late spring 2016. This conference originated as a methods meeting focused on in vivo voltammetric techniques and microdialysis. Over time, however, the scope has evolved to include a number of other methods for neurochemical detection that range from single-cell fluorescence in vitro and in vivo in animal models to whole-brain imaging in humans. Overall, MMiN provides a unique forum for introducing new developments in neurochemical detection, as well as for reporting exciting neurobiological insights provided by established and novel methods. This Viewpoint includes a brief history of the meeting, factors that have contributed its evolution, and some highlights of MMiN 2016.

  13. Data storage technology: Hardware and software, Appendix B

    NASA Technical Reports Server (NTRS)

    Sable, J. D.

    1972-01-01

    This project involves the development of more economical ways of integrating and interfacing new storage devices and data processing programs into a computer system. It involves developing interface standards and a software/hardware architecture which will make it possible to develop machine independent devices and programs. These will interface with the machine dependent operating systems of particular computers. The development project will not be to develop the software which would ordinarily be the responsibility of the manufacturer to supply, but to develop the standards with which that software is expected to confirm in providing an interface with the user or storage system.

  14. 21 CFR 870.4220 - Cardiopulmonary bypass heart-lung machine console.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Cardiopulmonary bypass heart-lung machine console... Cardiopulmonary bypass heart-lung machine console. (a) Identification. A cardiopulmonary bypass heart-lung machine... heart-lung machine. The console is designed to interface with the basic units used in a gas exchange...

  15. 21 CFR 870.4220 - Cardiopulmonary bypass heart-lung machine console.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... 21 Food and Drugs 8 2013-04-01 2013-04-01 false Cardiopulmonary bypass heart-lung machine console... Cardiopulmonary bypass heart-lung machine console. (a) Identification. A cardiopulmonary bypass heart-lung machine... heart-lung machine. The console is designed to interface with the basic units used in a gas exchange...

  16. 21 CFR 870.4220 - Cardiopulmonary bypass heart-lung machine console.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... 21 Food and Drugs 8 2012-04-01 2012-04-01 false Cardiopulmonary bypass heart-lung machine console... Cardiopulmonary bypass heart-lung machine console. (a) Identification. A cardiopulmonary bypass heart-lung machine... heart-lung machine. The console is designed to interface with the basic units used in a gas exchange...

  17. 21 CFR 870.4220 - Cardiopulmonary bypass heart-lung machine console.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Cardiopulmonary bypass heart-lung machine console... Cardiopulmonary bypass heart-lung machine console. (a) Identification. A cardiopulmonary bypass heart-lung machine... heart-lung machine. The console is designed to interface with the basic units used in a gas exchange...

  18. 21 CFR 870.4220 - Cardiopulmonary bypass heart-lung machine console.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... 21 Food and Drugs 8 2014-04-01 2014-04-01 false Cardiopulmonary bypass heart-lung machine console... Cardiopulmonary bypass heart-lung machine console. (a) Identification. A cardiopulmonary bypass heart-lung machine... heart-lung machine. The console is designed to interface with the basic units used in a gas exchange...

  19. Proceedings of the first workshop on Peripheral Machine Interfaces: going beyond traditional surface electromyography

    PubMed Central

    Castellini, Claudio; Artemiadis, Panagiotis; Wininger, Michael; Ajoudani, Arash; Alimusaj, Merkur; Bicchi, Antonio; Caputo, Barbara; Craelius, William; Dosen, Strahinja; Englehart, Kevin; Farina, Dario; Gijsberts, Arjan; Godfrey, Sasha B.; Hargrove, Levi; Ison, Mark; Kuiken, Todd; Marković, Marko; Pilarski, Patrick M.; Rupp, Rüdiger; Scheme, Erik

    2014-01-01

    One of the hottest topics in rehabilitation robotics is that of proper control of prosthetic devices. Despite decades of research, the state of the art is dramatically behind the expectations. To shed light on this issue, in June, 2013 the first international workshop on Present and future of non-invasive peripheral nervous system (PNS)–Machine Interfaces (MI; PMI) was convened, hosted by the International Conference on Rehabilitation Robotics. The keyword PMI has been selected to denote human–machine interfaces targeted at the limb-deficient, mainly upper-limb amputees, dealing with signals gathered from the PNS in a non-invasive way, that is, from the surface of the residuum. The workshop was intended to provide an overview of the state of the art and future perspectives of such interfaces; this paper represents is a collection of opinions expressed by each and every researcher/group involved in it. PMID:25177292

  20. Techniques and applications for binaural sound manipulation in human-machine interfaces

    NASA Technical Reports Server (NTRS)

    Begault, Durand R.; Wenzel, Elizabeth M.

    1990-01-01

    The implementation of binaural sound to speech and auditory sound cues (auditory icons) is addressed from both an applications and technical standpoint. Techniques overviewed include processing by means of filtering with head-related transfer functions. Application to advanced cockpit human interface systems is discussed, although the techniques are extendable to any human-machine interface. Research issues pertaining to three-dimensional sound displays under investigation at the Aerospace Human Factors Division at NASA Ames Research Center are described.

  1. Techniques and applications for binaural sound manipulation in human-machine interfaces

    NASA Technical Reports Server (NTRS)

    Begault, Durand R.; Wenzel, Elizabeth M.

    1992-01-01

    The implementation of binaural sound to speech and auditory sound cues (auditory icons) is addressed from both an applications and technical standpoint. Techniques overviewed include processing by means of filtering with head-related transfer functions. Application to advanced cockpit human interface systems is discussed, although the techniques are extendable to any human-machine interface. Research issues pertaining to three-dimensional sound displays under investigation at the Aerospace Human Factors Division at NASA Ames Research Center are described.

  2. Literate Specification: Using Design Rationale To Support Formal Methods in the Development of Human-Machine Interfaces.

    ERIC Educational Resources Information Center

    Johnson, Christopher W.

    1996-01-01

    The development of safety-critical systems (aircraft cockpits and reactor control rooms) is qualitatively different from that of other interactive systems. These differences impose burdens on design teams that must ensure the development of human-machine interfaces. Analyzes strengths and weaknesses of formal methods for the design of user…

  3. The Portals 4.0 network programming interface.

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Barrett, Brian W.; Brightwell, Ronald Brian; Pedretti, Kevin

    2012-11-01

    This report presents a specification for the Portals 4.0 network programming interface. Portals 4.0 is intended to allow scalable, high-performance network communication between nodes of a parallel computing system. Portals 4.0 is well suited to massively parallel processing and embedded systems. Portals 4.0 represents an adaption of the data movement layer developed for massively parallel processing platforms, such as the 4500-node Intel TeraFLOPS machine. Sandias Cplant cluster project motivated the development of Version 3.0, which was later extended to Version 3.3 as part of the Cray Red Storm machine and XT line. Version 4.0 is targeted to the next generationmore » of machines employing advanced network interface architectures that support enhanced offload capabilities.« less

  4. Hepatoprotective and Antioxidant Effect of Mangifera Indica Leaf Extracts against Mercuric Chloride-induced Liver Toxicity in Mice.

    PubMed

    Karuppanan, Muthupillai; Krishnan, Manigandan; Padarthi, Pavankumar; Namasivayam, Elangovan

    2014-01-01

    To explore the antioxidant and hepatoprotective effect of ethanolic Mangifera indica (EMI) and methanolic Mangifera indica (MMI) leaf extracts in mercuric chloride (HgCl 2 ) induced toxicity in Swiss albino mice. Toxicity in mice was induced with HgCl 2 (5.0 mg/kg, i.p.), followed by oral intervention with EMI and MMI extracts (25 mg and 50 mg/kg. body wt.) for 30 days. The extent of liver damage was assessed from the extents of histopathological, morphological, antioxidant and liver enzymes. Mercuric chloride-induced mice showed an increased cellular damage whereas leaf extracts of EMI and MMI-treated mice showed recovery of damaged hepatocytes. Mercuric chloride intoxicated mice exhibited a significant (p < 0.05) elevation in the liver enzymes (Aspartate amino transferase and Alanine amino transferase) and gradual decline in the cellular radical scavenging enzyme levels (Catalase, Glutathione-s-transferase and Glutathione peroxidase. The combined treatment with EMI and MMI leaf extracts significantly (p < 0.05) reversed these parameters. However, the effects of MMI leaf extract (50 mg/kg) were superior to those of EMI- treated mice possibly due to its potent radical scavenging property. These results suggest that oral supplementation of Mangifera indica extract remarkably reduces hepatotoxicity in mice possibly through its antioxidant potentials. How to cite this article: Karuppanan M, Krishnan M, Padarthi P, Namasivayam E. Hepatoprotec-tive and Antioxidant Effect of Mangifera Indica Leaf Extracts against Mercuric Chloride-induced Liver Toxicity in Mice. Euroasian J Hepato-Gastroenterol 2014;4(1):18-24.

  5. Hepatoprotective and Antioxidant Effect of Mangifera Indica Leaf Extracts against Mercuric Chloride-induced Liver Toxicity in Mice

    PubMed Central

    Karuppanan, Muthupillai; Krishnan, Manigandan; Padarthi, Pavankumar

    2014-01-01

    ABSTRACT Background To explore the antioxidant and hepatoprotective effect of ethanolic Mangifera indica (EMI) and methanolic Mangifera indica (MMI) leaf extracts in mercuric chloride (HgCl2) induced toxicity in Swiss albino mice. Materials and methods Toxicity in mice was induced with HgCl2 (5.0 mg/kg, i.p.), followed by oral intervention with EMI and MMI extracts (25 mg and 50 mg/kg. body wt.) for 30 days. Results and discussion The extent of liver damage was assessed from the extents of histopathological, morphological, antioxidant and liver enzymes. Mercuric chloride-induced mice showed an increased cellular damage whereas leaf extracts of EMI and MMI-treated mice showed recovery of damaged hepatocytes. Mercuric chloride intoxicated mice exhibited a significant (p < 0.05) elevation in the liver enzymes (Aspartate amino transferase and Alanine amino transferase) and gradual decline in the cellular radical scavenging enzyme levels (Catalase, Glutathione-s-transferase and Glutathione peroxidase. The combined treatment with EMI and MMI leaf extracts significantly (p < 0.05) reversed these parameters. However, the effects of MMI leaf extract (50 mg/kg) were superior to those of EMI- treated mice possibly due to its potent radical scavenging property. These results suggest that oral supplementation of Mangifera indica extract remarkably reduces hepatotoxicity in mice possibly through its antioxidant potentials. How to cite this article: Karuppanan M, Krishnan M, Padarthi P, Namasivayam E. Hepatoprotec-tive and Antioxidant Effect of Mangifera Indica Leaf Extracts against Mercuric Chloride-induced Liver Toxicity in Mice. Euroasian J Hepato-Gastroenterol 2014;4(1):18-24. PMID:29264314

  6. [Predictive model based multimetric index of macroinvertebrates for river health assessment].

    PubMed

    Chen, Kai; Yu, Hai Yan; Zhang, Ji Wei; Wang, Bei Xin; Chen, Qiu Wen

    2017-06-18

    Improving the stability of integrity of biotic index (IBI; i.e., multi-metric indices, MMI) across temporal and spatial scales is one of the most important issues in water ecosystem integrity bioassessment and water environment management. Using datasets of field-based macroinvertebrate and physicochemical variables and GIS-based natural predictors (e.g., geomorphology and climate) and land use variables collected at 227 river sites from 2004 to 2011 across the Zhejiang Province, China, we used random forests (RF) to adjust the effects of natural variations at temporal and spatial scales on macroinvertebrate metrics. We then developed natural variations adjusted (predictive) and unadjusted (null) MMIs and compared performance between them. The core me-trics selected for predictive and null MMIs were different from each other, and natural variations within core metrics in predictive MMI explained by RF models ranged between 11.4% and 61.2%. The predictive MMI was more precise and accurate, but less responsive and sensitive than null MMI. The multivariate nearest-neighbor test determined that 9 test sites and 1 most degraded site were flagged outside of the environmental space of the reference site network. We found that combination of predictive MMI developed by using predictive model and the nearest-neighbor test performed best and decreased risks of inferring type I (designating a water body as being in poor biological condition, when it was actually in good condition) and type II (designating a water body as being in good biological condition, when it was actually in poor condition) errors. Our results provided an effective method to improve the stability and performance of integrity of biotic index.

  7. Molecular responses of cells to 2-mercapto-1-methylimidazole gold nanoparticles (AuNPs)-mmi: investigations of histone methylation changes

    NASA Astrophysics Data System (ADS)

    Polverino, Arianna; Longo, Angela; Donizetti, Aldo; Drongitis, Denise; Frucci, Maria; Schiavo, Loredana; Carotenuto, Gianfranco; Nicolais, Luigi; Piscopo, Marina; Vitale, Emilia; Fucci, Laura

    2014-07-01

    While nanomedicine has an enormous potential to improve the precision of specific therapy, the ability to efficiently deliver these materials to regions of disease in vivo remains limited. In this study, we describe analyses of (AuNPs)-mmi cellular intake via fluorescence microscopy and its effects on H3K4 and H3K9 histone dimethylation. Specifically, we studied the level of H3K4 dimethylation in serving the role of an epigenetic marker of euchromatin, and of H3K9 dimethylation as a marker of transcriptional repression in four different cell lines. We analyzed histone di-methyl-H3K4 and di-methyl-H3K9 using either variable concentrations of nanoparticles or variable time points after cellular uptake. The observed methylation effects decreased consistently with decreasing (AuNPs)-mmi concentrations. Fluorescent microscopy and a binarization algorithm based on a thresholding process with RGB input images demonstrated the continued presence of (AuNPs)-mmi in cells at the lowest concentration used. Furthermore, our results show that the treated cell line used is able to rescue the untreated cell phenotype.

  8. Management of hyperthyroidism during pregnancy and lactation.

    PubMed

    Azizi, Fereidoun; Amouzegar, Atieh

    2011-06-01

    Poorly treated or untreated maternal overt hyperthyroidism may affect pregnancy outcome. Fetal and neonatal hypo- or hyper-thyroidism and neonatal central hypothyroidism may complicate health issues during intrauterine and neonatal periods. To review articles related to appropriate management of hyperthyroidism during pregnancy and lactation. A literature review was performed using MEDLINE with the terms 'hyperthyroidism and pregnancy', 'antithyroid drugs and pregnancy', 'radioiodine and pregnancy', 'hyperthyroidism and lactation', and 'antithyroid drugs and lactation', both separately and in conjunction with the terms 'fetus' and 'maternal.' Antithyroid drugs are the main therapy for maternal hyperthyroidism. Both methimazole (MMI) and propylthiouracil (PTU) may be used during pregnancy; however, PTU is preferred in the first trimester and should be replaced by MMI after this trimester. Choanal and esophageal atresia of fetus in MMI-treated and maternal hepatotoxicity in PTU-treated pregnancies are of utmost concern. Maintaining free thyroxine concentration in the upper one-third of each trimester-specific reference interval denotes success of therapy. MMI is the mainstay of the treatment of post partum hyperthyroidism, in particular during lactation. Management of hyperthyroidism during pregnancy and lactation requires special considerations and should be carefully implemented to avoid any adverse effects on the mother, fetus, and neonate.

  9. Central nervous system vasculitis after starting methimazole in a woman with Graves' disease.

    PubMed

    Tripodi, Pier Francesco; Ruggeri, Rosaria M; Campennì, Alfredo; Cucinotta, Mariapaola; Mirto, Angela; Lo Gullo, Renato; Baldari, Sergio; Trimarchi, Francesco; Cucinotta, Domenico; Russo, Giuseppina T

    2008-09-01

    Graves' disease (GD), a prototypical autoimmune disorder, is associated with other autoimmune diseases, including vasculitis. Antithyroid drugs, despite their postulated immunosuppressive effects, may cause several autoimmune disorders. Here we describe the first patient with central nervous system (CNS) vasculitis that developed shortly after the start of methimazole (MMI) treatment for GD. CNS vasculitis was suspected on the basis of the clinical features and neurologic examination, showing a reinforcement of deep reflexes, especially of the left knee and Achilles reflexes. The diagnosis was confirmed by a brain magnetic resonance imaging (MRI), which showed some hyperintensive spots in the subcortical substantia alba and in the parietal area bilaterally, and by a single-photon emission computed tomography (SPECT) imaging, which showed a nonhomogenous distribution of the blood flow in the brain, with a reduced perfusion on the left side of the frontotemporal and parietal regions, and on the right side of the frontotemporal area. MMI was stopped before total thyroidectomy, and symptoms resolved in the next 5 weeks. Six months after MMI was stopped, the brain MRI and SPECT had become normal. To our knowledge, this is the first report of CNS vasculitis related to MMI therapy.

  10. Use case driven approach to develop simulation model for PCS of APR1400 simulator

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Dong Wook, Kim; Hong Soo, Kim; Hyeon Tae, Kang

    2006-07-01

    The full-scope simulator is being developed to evaluate specific design feature and to support the iterative design and validation in the Man-Machine Interface System (MMIS) design of Advanced Power Reactor (APR) 1400. The simulator consists of process model, control logic model, and MMI for the APR1400 as well as the Power Control System (PCS). In this paper, a use case driven approach is proposed to develop a simulation model for PCS. In this approach, a system is considered from the point of view of its users. User's view of the system is based on interactions with the system and themore » resultant responses. In use case driven approach, we initially consider the system as a black box and look at its interactions with the users. From these interactions, use cases of the system are identified. Then the system is modeled using these use cases as functions. Lower levels expand the functionalities of each of these use cases. Hence, starting from the topmost level view of the system, we proceeded down to the lowest level (the internal view of the system). The model of the system thus developed is use case driven. This paper will introduce the functionality of the PCS simulation model, including a requirement analysis based on use case and the validation result of development of PCS model. The PCS simulation model using use case will be first used during the full-scope simulator development for nuclear power plant and will be supplied to Shin-Kori 3 and 4 plant. The use case based simulation model development can be useful for the design and implementation of simulation models. (authors)« less

  11. Strain Accumulation Estimated from Seafloor Crustal Deformation at the Nankai Trough, Japan

    NASA Astrophysics Data System (ADS)

    Tadokoro, K.; Watanabe, T.; Nagai, S.; Ikuta, R.; Okuda, T.; Kenji, Y.; Sakata, T.

    2012-12-01

    Our research has developed an observation system for seafloor crustal deformation composed of the kinematic GPS and acoustic ranging techniques [Tadokoro et al., 2006; Ikuta et al., 2008]. We monitored crustal deformation at the Nankai Trough, Japan, where the Philippine Sea Plate subducts beneath the Amurian Plate. The convergence rate is predicted at 60 mm/y in the N59W direction by the Euler vector of REVEL [Sella et al., 2002]. We installed three monitoring sites (named KMN, KMS, and KME) on the seafloor at depths of about 1920-2030 m. The sites KMN and KMS are installed perpendicular to the trough axis with a spacing of 20 km; the site KME is 50 km from KMN and KMS in the direction parallel to the trough axis. The monitoring was started in 2004, 2005, and 2008 at KMS, KMN, and KME, respectively. The numbers of measurements are 16, 20, and 5 times at KMN, KMS, and KME, respectively. We obtained 3-7 years averaged horizontal site velocities within ITRF2000 adopting a robust estimation method with Tukey's biweight function to the time series of site position measured until the end of 2011. Substituting the synthetic rigid block motions of the Amurian Plate from the velocities within ITRF2000, we obtained the following site velocities with respect to the Amurian Plate [Tadokoro et al., 2012]: KMN 41±4 mm/y, N77±7W KMS 43±5 mm/y, N80±6W KME 42±5 mm/y, N80±7W In contrast, the on-land GPS horizontal velocities along the coast is 23-33 mm/y toward N74-80W. The present observational results show: (1) the velocity vectors are all the same length and direction, which indicates no internal deformation in this region; (2) the back-slip model predicts that the plate interface beneath the region is uniformly locked with coupling ratios of 60-80 %, indicating strain accumulation that will be released during the anticipated mega-thrust Tonankai earthquake; and (3) the directions of site velocities differ from that of convergence vector by 20 degrees, which is affected by the oblique subduction of the Philippine Sea Plate. We started monitoring of seafloor crustal deformation at a new site, KMC, in this year. This site is located between KMN and KMS. The monitoring at KMC enable us to depict dense (with a span of 10 km) crustal deformation profile that is related to strain accumulation, in the direction perpendicular to the trough axis. We plan to measure the position at KMC twice by the end of this year. We also continue to measure the position at KMS and KME. The number of measurements at KME is extremely few compared to the other sites in particular, and it is important to continue the measurement for obtaining stable site velocity. We report the results of monitoring preformed in this year. Acknowledgments: We are grateful to the captain and crews of R/V "Asama" of Mie Prefecture Fisheries Research Institute, Japan. This study has been partly promoted by Ministry of Education, Culture, Sports, Science and Technology, Japanese Government.

  12. Selectivity and Longevity of Peripheral-Nerve and Machine Interfaces: A Review

    PubMed Central

    Ghafoor, Usman; Kim, Sohee; Hong, Keum-Shik

    2017-01-01

    For those individuals with upper-extremity amputation, a daily normal living activity is no longer possible or it requires additional effort and time. With the aim of restoring their sensory and motor functions, theoretical and technological investigations have been carried out in the field of neuroprosthetic systems. For transmission of sensory feedback, several interfacing modalities including indirect (non-invasive), direct-to-peripheral-nerve (invasive), and cortical stimulation have been applied. Peripheral nerve interfaces demonstrate an edge over the cortical interfaces due to the sensitivity in attaining cortical brain signals. The peripheral nerve interfaces are highly dependent on interface designs and are required to be biocompatible with the nerves to achieve prolonged stability and longevity. Another criterion is the selection of nerves that allows minimal invasiveness and damages as well as high selectivity for a large number of nerve fascicles. In this paper, we review the nerve-machine interface modalities noted above with more focus on peripheral nerve interfaces, which are responsible for provision of sensory feedback. The invasive interfaces for recording and stimulation of electro-neurographic signals include intra-fascicular, regenerative-type interfaces that provide multiple contact channels to a group of axons inside the nerve and the extra-neural-cuff-type interfaces that enable interaction with many axons around the periphery of the nerve. Section Current Prosthetic Technology summarizes the advancements made to date in the field of neuroprosthetics toward the achievement of a bidirectional nerve-machine interface with more focus on sensory feedback. In the Discussion section, the authors propose a hybrid interface technique for achieving better selectivity and long-term stability using the available nerve interfacing techniques. PMID:29163122

  13. A new macroseismic intensity prediction equation and magnitude estimates of the 1811-1812 New Madrid and 1886 Charleston, South Carolina, earthquakes

    NASA Astrophysics Data System (ADS)

    Boyd, O. S.; Cramer, C. H.

    2013-12-01

    We develop an intensity prediction equation (IPE) for the Central and Eastern United States, explore differences between modified Mercalli intensities (MMI) and community internet intensities (CII) and the propensity for reporting, and estimate the moment magnitudes of the 1811-1812 New Madrid, MO, and 1886 Charleston, SC, earthquakes. We constrain the study with North American census data, the National Oceanic and Atmospheric Administration MMI dataset (responses between 1924 and 1985), and the USGS ';Did You Feel It?' CII dataset (responses between June, 2000 and August, 2012). The combined intensity dataset has more than 500,000 felt reports for 517 earthquakes with magnitudes between 2.5 and 7.2. The IPE has the basic form, MMI=c1+c2M+c3exp(λ)+c4λ. where M is moment magnitude and λ is mean log hypocentral distance. Previous IPEs use a limited dataset of MMI, do not differentiate between MMI and CII data in the CEUS, nor account for spatial variations in population. These factors can have an impact at all magnitudes, especially the last factor at large magnitudes and small intensities where the population drops to zero in the Atlantic Ocean and Gulf of Mexico. We assume that the number of reports of a given intensity have hypocentral distances that are log-normally distributed, the distribution of which is modulated by population and the propensity for individuals to report their experience. We do not account for variations in stress drop, regional variations in Q, or distance-dependent geometrical spreading. We simulate the distribution of reports of a given intensity accounting for population and use a grid search method to solve for the fraction of population to report the intensity, the standard deviation of the log-normal distribution and the mean log hypocentral distance, which appears in the above equation. We find that lower intensities, both CII and MMI, are less likely to be reported than greater intensities. Further, there are strong spatial variations in the level of CII reporting. For example, large metropolitan areas appear to have a lower level of reporting relative to rural areas. In general, we find that intensities decrease with increasing distance and decreasing magnitude, as expected. Coefficients for the IPE are c1=1.98×0.13 c2=1.76×0.02 c3=-0.0027×0.0004, and c4=-1.26×0.03. We find significant differences in mean log hypocentral distance between MMI- and CII-based reporting, particularly at smaller mean log distance and higher intensity. Values of mean log distance for CII at high intensity tend to be smaller than for MMI at the same value of intensity. The new IPE leads to magnitude estimates for the 1811-1812 New Madrid earthquakes that are within the broad range of those determined previously. Using three MMI datasets for the New Madrid mainshocks, the new relation results in estimates for the moment magnitudes of the December 16th, 1811, January 23rd, 1812, and February 7th, 1812 mainshocks and December 16th dawn aftershock of 7.1¬¬-7.4, 7.2, 7.5-7.7, and 6.7-7.2, respectively, with a magnitude uncertainty of about ×0.4 units. We estimate a magnitude of 7.0×0.3 for the 1886 Charleston, SC earthquake.

  14. Quaternary Basalts in Grand Canyon: Correlation of Flows Using Lidar, 40Ar/39Ar Dating, Geochemical Correlation, Neotectonic Studies, and History of Lava Dams

    NASA Astrophysics Data System (ADS)

    Crow, R. S.; Karlstrom, K. E.; McIntosh, W. C.; Dunbar, N. W.; Peters, L.; Raucci, J.; Umhoefer, P. J.

    2005-12-01

    In western Grand Canyon, basalts flowed into the already existing canyon from at least 719 ka to present. These basalts provide a key for deciphering Quaternary rates of incision, neotectonic slip rates on the Toroweap and Hurricane faults, and the history of lava dams. Stratigraphy and/or inset relationships between basalt flows is exceedingly complex because of the multiple eruptions, extreme topography, long transport distance, and incomplete preservation. Correlation of flows using 40Ar/39Ar dating, LIDAR data, orthophotography, and geochemical analysis, as well as structural and geomorphic studies, lead to a working hypothesis for four major episodes of basaltic eruptive activity. From 719 to 484 Ma major volcanoes erupted near the Toroweap fault zone. The extent of the remnants and presence of 527 ka dikes indicates that cones where built within Grand Canyon during this phase. These flows had the longest outflow (719 ka flow at mile 246). At 349 to 296 ka flows seem to have entered the canyon at Whitmore Wash, north rim. The two remaining episodes, dated at 199-193 ka and 109-97 ka are interpreted to have cascaded into the canyon at and upstream from Whitmore Wash. LIDAR/orthophotography interpretation of the tops and bottoms of the flows and geochemical analysis of phenocrysts aid in correlation of undated remnants and reconstructing the shape of volcanic edifices. Flows dated from 720-450 ka include Prospect, Black Ledge, D-Dam, and Toroweap flows, thus Black Ledge flows are considerably older than previously thought. The 350 to 300 flows include Whitmore, Layered Diabase, Massive Diabase, and 177-mile flows. All the dated 200 and 100 ka flows have been called Grey Ledge flows, suggesting that the Grey Ledge represents two distinct events. Basalt data indicate an interaction of canyon incision and Quaternary fault slip. Bedrock incision rates are calculated using dated flows that overly bedrock straths. Rates vary across active faults indicating fault dampening of apparent river incision rates. Incision rates for eastern Grand Canyon are 127 m/my over 387 ka. Similar rates just east of the Toroweap faults (136 m/my over 349 ka and 153 m/my over 484 ka) suggest that a fairly uniform regional rate of ~ 140 m/my can be considered the average rate for Grand Canyon incision east of the Toroweap fault. This is subequal to the sum of apparent incision rate just below the Toroweap fault (56 m/my over 484 ka) plus fault slip rate (90 m/my over 550 ka). Similarly, apparent incision rates below the Hurricane fault (66 m/my over 527 ka and 76 m/my over 604 ka, near Granite Park) plus fault slip rate (~80±20 m/my over 185 ka) is subequal to the far field incision rate. Accumulating data suggests that apparent incision rates are lowest adjacent to faults in the hanging wall and highest adjacent to faults in the footwall, with rates varying systematically across fault blocks. This suggests that faulting is taking place by domino rotation of blocks bounded by normal faults with mild listric character. These new empirical data help constrain physical models for Quaternary fault slip across the active Colorado Plateau- Basin and Range bounding structures.

  15. Knowledge-based load leveling and task allocation in human-machine systems

    NASA Technical Reports Server (NTRS)

    Chignell, M. H.; Hancock, P. A.

    1986-01-01

    Conventional human-machine systems use task allocation policies which are based on the premise of a flexible human operator. This individual is most often required to compensate for and augment the capabilities of the machine. The development of artificial intelligence and improved technologies have allowed for a wider range of task allocation strategies. In response to these issues a Knowledge Based Adaptive Mechanism (KBAM) is proposed for assigning tasks to human and machine in real time, using a load leveling policy. This mechanism employs an online workload assessment and compensation system which is responsive to variations in load through an intelligent interface. This interface consists of a loading strategy reasoner which has access to information about the current status of the human-machine system as well as a database of admissible human/machine loading strategies. Difficulties standing in the way of successful implementation of the load leveling strategy are examined.

  16. Transfer of control system interface solutions from other domains to the thermal power industry.

    PubMed

    Bligård, L-O; Andersson, J; Osvalder, A-L

    2012-01-01

    In a thermal power plant the operators' roles are to control and monitor the process to achieve efficient and safe production. To achieve this, the human-machine interfaces have a central part. The interfaces need to be updated and upgraded together with the technical functionality to maintain optimal operation. One way of achieving relevant updates is to study other domains and see how they have solved similar issues in their design solutions. The purpose of this paper is to present how interface design solution ideas can be transferred from domains with operator control to thermal power plants. In the study 15 domains were compared using a model for categorisation of human-machine systems. The result from the domain comparison showed that nuclear power, refinery and ship engine control were most similar to thermal power control. From the findings a basic interface structure and three specific display solutions were proposed for thermal power control: process parameter overview, plant overview, and feed water view. The systematic comparison of the properties of a human-machine system allowed interface designers to find suitable objects, structures and navigation logics in a range of domains that could be transferred to the thermal power domain.

  17. The reliability and validity of multiple mini interviews (MMIs) in values based recruitment to nursing, midwifery and paramedic practice programmes: Findings from an evaluation study.

    PubMed

    Callwood, Alison; Cooke, Debbie; Bolger, Sarah; Lemanska, Agnieszka; Allan, Helen

    2018-01-01

    Universities in the United Kingdom (UK) are required to incorporate values based recruitment (VBR) into their healthcare student selection processes. This reflects an international drive to strengthen the quality of healthcare service provision. This paper presents novel findings in relation to the reliability and predictive validity of multiple mini interviews (MMIs); one approach to VBR widely being employed by universities. To examine the reliability (internal consistency) and predictive validity of MMIs using end of Year One practice outcomes of under-graduate pre-registration adult, child, mental health nursing, midwifery and paramedic practice students. Cross-discipline evaluation study. One university in the United Kingdom. Data were collected in two streams: applicants to A) The September 2014 and 2015 Midwifery Studies programmes; B) September 2015 adult; Child and Mental Health Nursing and Paramedic Practice programmes. Fifty-seven midwifery students commenced their programme in 2014 and 69 in 2015; 47 and 54 agreed to participate and completed Year One respectively. 333 healthcare students commenced their programmes in September 2015. Of these, 281 agreed to participate and completed their first year (180 adult, 33 child and 34 mental health nursing and 34 paramedic practice students). Stream A featured a seven station four-minute model with one interviewer at each station and in Stream B a six station model was employed. Cronbach's alpha was used to assess MMI station internal consistency and Pearson's moment correlation co-efficient to explore associations between participants' admission MMI score and end of Year one clinical practice outcomes (OSCE and mentor grading). Stream A: Significant correlations are reported between midwifery applicant's MMI scores and end of Year One practice outcomes. A multivariate linear regression model demonstrated that MMI score significantly predicted end of Year One practice outcomes controlling for age and academic entry level: coefficients 0.195 (p=0.002) and 0.116 (p=0.002) for OSCE and mentor grading respectively. In Stream B no significant correlations were found between MMI score and practice outcomes measured by mentor grading. Internal consistency for each MMI station was 'excellent' with values ranging from 0.966-0.974 across Streams A and B. This novel, cross-discipline study shows that MMIs are reliable VBR tools which have predictive validity when a seven station model is used. These data are important given the current international use of different MMI models in healthcare student selection processes. Copyright © 2017. Published by Elsevier Ltd.

  18. European public deliberation on brain machine interface technology: five convergence seminars.

    PubMed

    Jebari, Karim; Hansson, Sven-Ove

    2013-09-01

    We present a novel procedure to engage the public in ethical deliberations on the potential impacts of brain machine interface technology. We call this procedure a convergence seminar, a form of scenario-based group discussion that is founded on the idea of hypothetical retrospection. The theoretical background of this procedure and the results of five seminars are presented.

  19. Human Machine Interfaces for Teleoperators and Virtual Environments

    NASA Technical Reports Server (NTRS)

    Durlach, Nathaniel I. (Compiler); Sheridan, Thomas B. (Compiler); Ellis, Stephen R. (Compiler)

    1991-01-01

    In Mar. 1990, a meeting organized around the general theme of teleoperation research into virtual environment display technology was conducted. This is a collection of conference-related fragments that will give a glimpse of the potential of the following fields and how they interplay: sensorimotor performance; human-machine interfaces; teleoperation; virtual environments; performance measurement and evaluation methods; and design principles and predictive models.

  20. Human factors in the presentation of computer-generated information - Aspects of design and application in automated flight traffic

    NASA Technical Reports Server (NTRS)

    Roske-Hofstrand, Renate J.

    1990-01-01

    The man-machine interface and its influence on the characteristics of computer displays in automated air traffic is discussed. The graphical presentation of spatial relationships and the problems it poses for air traffic control, and the solution of such problems are addressed. Psychological factors involved in the man-machine interface are stressed.

  1. Cursor control by Kalman filter with a non-invasive body–machine interface

    PubMed Central

    Seáñez-González, Ismael; Mussa-Ivaldi, Ferdinando A

    2015-01-01

    Objective We describe a novel human–machine interface for the control of a two-dimensional (2D) computer cursor using four inertial measurement units (IMUs) placed on the user’s upper-body. Approach A calibration paradigm where human subjects follow a cursor with their body as if they were controlling it with their shoulders generates a map between shoulder motions and cursor kinematics. This map is used in a Kalman filter to estimate the desired cursor coordinates from upper-body motions. We compared cursor control performance in a centre-out reaching task performed by subjects using different amounts of information from the IMUs to control the 2D cursor. Main results Our results indicate that taking advantage of the redundancy of the signals from the IMUs improved overall performance. Our work also demonstrates the potential of non-invasive IMU-based body–machine interface systems as an alternative or complement to brain–machine interfaces for accomplishing cursor control in 2D space. Significance The present study may serve as a platform for people with high-tetraplegia to control assistive devices such as powered wheelchairs using a joystick. PMID:25242561

  2. Human-machine interface for a VR-based medical imaging environment

    NASA Astrophysics Data System (ADS)

    Krapichler, Christian; Haubner, Michael; Loesch, Andreas; Lang, Manfred K.; Englmeier, Karl-Hans

    1997-05-01

    Modern 3D scanning techniques like magnetic resonance imaging (MRI) or computed tomography (CT) produce high- quality images of the human anatomy. Virtual environments open new ways to display and to analyze those tomograms. Compared with today's inspection of 2D image sequences, physicians are empowered to recognize spatial coherencies and examine pathological regions more facile, diagnosis and therapy planning can be accelerated. For that purpose a powerful human-machine interface is required, which offers a variety of tools and features to enable both exploration and manipulation of the 3D data. Man-machine communication has to be intuitive and efficacious to avoid long accustoming times and to enhance familiarity with and acceptance of the interface. Hence, interaction capabilities in virtual worlds should be comparable to those in the real work to allow utilization of our natural experiences. In this paper the integration of hand gestures and visual focus, two important aspects in modern human-computer interaction, into a medical imaging environment is shown. With the presented human- machine interface, including virtual reality displaying and interaction techniques, radiologists can be supported in their work. Further, virtual environments can even alleviate communication between specialists from different fields or in educational and training applications.

  3. Human facial neural activities and gesture recognition for machine-interfacing applications.

    PubMed

    Hamedi, M; Salleh, Sh-Hussain; Tan, T S; Ismail, K; Ali, J; Dee-Uam, C; Pavaganun, C; Yupapin, P P

    2011-01-01

    The authors present a new method of recognizing different human facial gestures through their neural activities and muscle movements, which can be used in machine-interfacing applications. Human-machine interface (HMI) technology utilizes human neural activities as input controllers for the machine. Recently, much work has been done on the specific application of facial electromyography (EMG)-based HMI, which have used limited and fixed numbers of facial gestures. In this work, a multipurpose interface is suggested that can support 2-11 control commands that can be applied to various HMI systems. The significance of this work is finding the most accurate facial gestures for any application with a maximum of eleven control commands. Eleven facial gesture EMGs are recorded from ten volunteers. Detected EMGs are passed through a band-pass filter and root mean square features are extracted. Various combinations of gestures with a different number of gestures in each group are made from the existing facial gestures. Finally, all combinations are trained and classified by a Fuzzy c-means classifier. In conclusion, combinations with the highest recognition accuracy in each group are chosen. An average accuracy >90% of chosen combinations proved their ability to be used as command controllers.

  4. A novel device for head gesture measurement system in combination with eye-controlled human machine interface

    NASA Astrophysics Data System (ADS)

    Lin, Chern-Sheng; Ho, Chien-Wa; Chang, Kai-Chieh; Hung, San-Shan; Shei, Hung-Jung; Yeh, Mau-Shiun

    2006-06-01

    This study describes the design and combination of an eye-controlled and a head-controlled human-machine interface system. This system is a highly effective human-machine interface, detecting head movement by changing positions and numbers of light sources on the head. When the users utilize the head-mounted display to browse a computer screen, the system will catch the images of the user's eyes with CCD cameras, which can also measure the angle and position of the light sources. In the eye-tracking system, the program in the computer will locate each center point of the pupils in the images, and record the information on moving traces and pupil diameters. In the head gesture measurement system, the user wears a double-source eyeglass frame, so the system catches images of the user's head by using a CCD camera in front of the user. The computer program will locate the center point of the head, transferring it to the screen coordinates, and then the user can control the cursor by head motions. We combine the eye-controlled and head-controlled human-machine interface system for the virtual reality applications.

  5. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Dirske, R.D.; Hauck, P.C.; Kachmar, R.P.

    In 1990, the federal government enacted the Clean Air Amendment. This required many public power utilities across the country to make modifications to their fossil fueled power plants to comply with the mandated emission levels by May 1995. At Pennsylvania Electric Company`s (PENELEC) Shawville Station, Units 3 and 4, the mandates established maximum nitrogen oxides (NOx) emission levels at 0.45 lbs/MMBTU. In an effort to comply with the new reduced emission levels, PENELEC chose to implement the Asea Brown Boveri-Combustion Engineering`s (ABB-CE) Low NOx Concentric Firing System III (LNCFS-III). PENELEC also took this opportunity to replace other controls because theirmore » implementation would have relatively little impact on the overall cost of the project and would enhance the ability of the operators to better control NOx emissions. This paper discusses the implementation of the new controls in a distributed control system (DCS), interfacing the DCS with the existing pneumatic combustion controls, and maintaining the boiler control benchboard as the primary operator interface, thereby, reducing the impact of the changes to the MMI and the overall cost of the project.« less

  6. Nonlinear Structural Health Monitoring of the Responsive Space Satellite Systems Using Magneto Elastic Active Sensors (MEAS)

    DTIC Science & Technology

    2011-11-30

    detection of fatigue damage at early stage, well before onset of fracture and crack development. Analytical and numerical models of MEAS and MMI are...stage, well before onset of fracture and crack development. Analytical and numerical models of MEAS and MMI are suggested. Finally, MEAS capability...47  2.4.1  Far-Field Crack Detection

  7. Intensity distribution and isoseismal maps for the Nisqually, Washington, earthquake of 28 February 2001

    USGS Publications Warehouse

    Dewey, James W.; Hopper, Margaret G.; Wald, David J.; Quitoriano, Vincent; Adams, Elizabeth R.

    2002-01-01

    We present isoseismal maps, macroseismic intensities, and community summaries of damage for the MW=6.8 Nisqually, Washington, earthquake of 28 February, 2001. For many communities, two types of macroseismic intensity are assigned, the traditional U.S. Geological Survey Modified Mercalli Intensities (USGS MMI) and a type of intensity newly introduced with this paper, the USGS Reviewed Community Internet Intensity (RCII). For most communities, the RCII is a reviewed version of the Community Internet Intensity (CII) of Wald and others (1999). For some communities, RCII is assigned from such non-CII sources as press reports, engineering reports, and field reconnaissance observations. We summarize differences between procedures used to assign RCII and USGS MMI, and we show that the two types of intensity are nonetheless very similar for the Nisqually earthquake. We do not see evidence for systematic differences between RCII and USGS MMI that would approach one intensity unit, at any level of shaking, but we document a tendency for the RCII to be slightly lower than MMI in regions of low intensity and slightly higher than MMI in regions of high intensity. The highest RCII calculated for the Nisqually earthquake is 7.6, calculated for zip code 98134, which includes the ?south of downtown? (Sodo) area of Seattle and Harbor Island. By comparison, we assigned a traditional USGS MMI 8 to the Sodo area of Seattle. In all, RCII of 6.5 and higher were assigned to 58 zip-code regions. At the lowest intensities, the Nisqually earthquake was felt over an area of approximately 350,000 square km (approximately 135,000 square miles) in Washington, Oregon, Idaho, Montana, and southern British Columbia, Canada. On the basis of macroseismic effects, we infer that shaking in the southern Puget Sound region was somewhat less for the 2001 Nisqually earthquake than for the Puget Sound earthquake of April 13, 1949, which had nearly the same hypocenter and magnitude. Allowing for differences in hypocenter, shaking in the 2001 earthquake was very similar to that produced by the Puget Sound earthquake of April 25, 1965. First-person accounts of the effects of the 2001 earthquake on individual households are given for some communities.

  8. The portals 4.0.1 network programming interface.

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Barrett, Brian W.; Brightwell, Ronald Brian; Pedretti, Kevin

    2013-04-01

    This report presents a specification for the Portals 4.0 network programming interface. Portals 4.0 is intended to allow scalable, high-performance network communication between nodes of a parallel computing system. Portals 4.0 is well suited to massively parallel processing and embedded systems. Portals 4.0 represents an adaption of the data movement layer developed for massively parallel processing platforms, such as the 4500-node Intel TeraFLOPS machine. Sandias Cplant cluster project motivated the development of Version 3.0, which was later extended to Version 3.3 as part of the Cray Red Storm machine and XT line. Version 4.0 is targeted to the next generationmore » of machines employing advanced network interface architectures that support enhanced offload capabilities. 3« less

  9. Optimal design method to minimize users' thinking mapping load in human-machine interactions.

    PubMed

    Huang, Yanqun; Li, Xu; Zhang, Jie

    2015-01-01

    The discrepancy between human cognition and machine requirements/behaviors usually results in serious mental thinking mapping loads or even disasters in product operating. It is important to help people avoid human-machine interaction confusions and difficulties in today's mental work mastered society. Improving the usability of a product and minimizing user's thinking mapping and interpreting load in human-machine interactions. An optimal human-machine interface design method is introduced, which is based on the purpose of minimizing the mental load in thinking mapping process between users' intentions and affordance of product interface states. By analyzing the users' thinking mapping problem, an operating action model is constructed. According to human natural instincts and acquired knowledge, an expected ideal design with minimized thinking loads is uniquely determined at first. Then, creative alternatives, in terms of the way human obtains operational information, are provided as digital interface states datasets. In the last, using the cluster analysis method, an optimum solution is picked out from alternatives, by calculating the distances between two datasets. Considering multiple factors to minimize users' thinking mapping loads, a solution nearest to the ideal value is found in the human-car interaction design case. The clustering results show its effectiveness in finding an optimum solution to the mental load minimizing problems in human-machine interaction design.

  10. Do Multiple Mini-Interview and Traditional Interview Scores Differ in Their Associations With Acceptance Offers Within and Across Five California Medical Schools?

    PubMed

    Jerant, Anthony; Henderson, Mark C; Griffin, Erin; Hall, Theodore R; Kelly, Carolyn J; Peterson, Ellena M; Wofsy, David; Franks, Peter

    2018-03-20

    In single-school studies, multiple mini-interview (MMI) and traditional interview (TI) scores are associated with acceptance offers. Unexamined is whether scores at one school are associated with acceptance at other schools; such analyses would mitigate single-school design biases and better estimate how well interviews capture desired applicant attributes. Using data from the five California Longitudinal Evaluation of Admissions Practices (CA-LEAP) public medical schools, the authors examined associations of MMI and TI scores with acceptance offers within and across schools. The analyses included applicants who interviewed at ≥1 CA-LEAP school during the 2011-2013 admissions cycles, when three CA-LEAP schools employed TIs and two employed MMIs. Interview scores were standardized (z-scores: mean = 0, SD = 1) and associations with acceptance offers were examined within and across schools in analyses stratified by school, adjusting for applicant sociodemographics, academic metrics, year, and total number of interviews. Of 4,993 applicants interviewed, 428 (8.6%) interviewed at both MMI schools, 681 (13.6%) at ≥2 TI schools, and 1,327 (26.6%) at ≥1 MMI and ≥1 TI school. For each school, acceptance was associated with interview score at that school and also with interview scores at the other four schools. Cross-school associations of MMI versus TI scores with acceptance did not differ statistically. Interview score at a given CA-LEAP school was associated with acceptance at the other four schools, with no significant differences in associations for MMIs versus TIs. The findings suggest both MMIs and TIs captured attributes valued by admissions teams across CA-LEAP schools.

  11. Dose-responses for mortality from cerebrovascular and heart diseases in atomic bomb survivors: 1950-2003.

    PubMed

    Schöllnberger, Helmut; Eidemüller, Markus; Cullings, Harry M; Simonetto, Cristoforo; Neff, Frauke; Kaiser, Jan Christian

    2018-03-01

    The scientific community faces important discussions on the validity of the linear no-threshold (LNT) model for radiation-associated cardiovascular diseases at low and moderate doses. In the present study, mortalities from cerebrovascular diseases (CeVD) and heart diseases from the latest data on atomic bomb survivors were analyzed. The analysis was performed with several radio-biologically motivated linear and nonlinear dose-response models. For each detrimental health outcome one set of models was identified that all fitted the data about equally well. This set was used for multi-model inference (MMI), a statistical method of superposing different models to allow risk estimates to be based on several plausible dose-response models rather than just relying on a single model of choice. MMI provides a more accurate determination of the dose response and a more comprehensive characterization of uncertainties. It was found that for CeVD, the dose-response curve from MMI is located below the linear no-threshold model at low and medium doses (0-1.4 Gy). At higher doses MMI predicts a higher risk compared to the LNT model. A sublinear dose-response was also found for heart diseases (0-3 Gy). The analyses provide no conclusive answer to the question whether there is a radiation risk below 0.75 Gy for CeVD and 2.6 Gy for heart diseases. MMI suggests that the dose-response curves for CeVD and heart diseases in the Lifespan Study are sublinear at low and moderate doses. This has relevance for radiotherapy treatment planning and for international radiation protection practices in general.

  12. Single voxel magnetic resonance spectroscopy at 3 Tesla in a memory disorders clinic: early right hippocampal NAA/Cr loss in mildly impaired subjects.

    PubMed

    Caserta, Maria T; Ragin, Ann; Hermida, Adriana P; Ahrens, R John; Wise, Leon

    2008-11-30

    In this study, we use magnetic resonance spectroscopy (MRS) at 3 Tesla to measure N-acetyl aspartate (NAA), myo-inositol (mI) and choline (Cho) to creatine (Cr) ratios in R (right) and L (left) hippocampi (H) in 8 mildly memory impaired (MMI), 6 probable Alzheimer's Disease (PRAD), and 17 control subjects. NAA/Cr was significantly reduced in the RH in the MMI group and bilaterally in the PRAD group vs. controls. No other metabolite differences were noted between the three groups. Five MMI subjects have converted to PRAD in follow-up. These findings suggest that RH NAA/Cr ratios measured at 3 Tesla may be a sensitive marker of future progression to dementia in a clinically defined population with isolated memory complaints.

  13. High performace silicon 2x2 optical switch based on a thermo-optically tunable multimode interference coupler and efficient electrodes.

    PubMed

    Rosa, Álvaro; Gutiérrez, Ana; Brimont, Antoine; Griol, Amadeu; Sanchis, Pablo

    2016-01-11

    Optical switches based on tunable multimode interference (MMI) couplers can simultaneously reduce the footprint and increase the tolerance against fabrication deviations. Here, a compact 2x2 silicon switch based on a thermo-optically tunable MMI structure with a footprint of only 0.005 mm(2) is proposed and demonstrated. The MMI structure has been optimized using a silica trench acting as a thermal isolator without introducing any substantial loss penalty or crosstalk degradation. Furthermore, the electrodes performance have significantly been improved via engineering the heater geometry and using two metallization steps. Thereby, a drastic power consumption reduction of around 90% has been demonstrated yielding to values as low as 24.9 mW. Furthermore, very fast switching times of only 1.19 µs have also been achieved.

  14. A compact thermo-optical multimode-interference silicon-based 1 × 4 nano-photonic switch.

    PubMed

    Zhou, Haifeng; Song, Junfeng; Chee, Edward K S; Li, Chao; Zhang, Huijuan; Lo, Guoqiang

    2013-09-09

    An ultra-compact multimode-interference (MMI)-based 1 × 4 nano-photonic switch is demonstrated by employing silicon thermo-optical effect on SOI platform. The device performance is systematically characterized by comprehensively investigating the constituent building blocks, including 1 × 4 power splitter, 4 × 4 MMI coupler and groove-isolated thermo-optical heaters. An instructive model is established to statistically estimate the required power consumption and investigate the influence of the power imbalance of the 4 × 4 MMI coupler on the switching performance. At the designed wavelength of 1550 nm, the average insertion loss of different switching states is 1.7 dB, and the transmission imbalance is 1.05 dB. The worst extinction ratio and crosstalk of all the output ports reach 11.48 dB and -11.38 dB, respectively.

  15. Soft, Conformal Bioelectronics for a Wireless Human-Wheelchair Interface

    PubMed Central

    Mishra, Saswat; Norton, James J. S.; Lee, Yongkuk; Lee, Dong Sup; Agee, Nicolas; Chen, Yanfei; Chun, Youngjae; Yeo, Woon-Hong

    2017-01-01

    There are more than 3 million people in the world whose mobility relies on wheelchairs. Recent advancement on engineering technology enables more intuitive, easy-to-use rehabilitation systems. A human-machine interface that uses non-invasive, electrophysiological signals can allow a systematic interaction between human and devices; for example, eye movement-based wheelchair control. However, the existing machine-interface platforms are obtrusive, uncomfortable, and often cause skin irritations as they require a metal electrode affixed to the skin with a gel and acrylic pad. Here, we introduce a bioelectronic system that makes dry, conformal contact to the skin. The mechanically comfortable sensor records high-fidelity electrooculograms, comparable to the conventional gel electrode. Quantitative signal analysis and infrared thermographs show the advantages of the soft biosensor for an ergonomic human-machine interface. A classification algorithm with an optimized set of features shows the accuracy of 94% with five eye movements. A Bluetooth-enabled system incorporating the soft bioelectronics demonstrates a precise, hands-free control of a robotic wheelchair via electrooculograms. PMID:28152485

  16. Flexible Parsing.

    DTIC Science & Technology

    1986-06-30

    Machine Studies .. 14. Minton, S. N., Hayes, P. J., and Fain, J. E. Controlling Search in Flexible Parsing. Proc. Ninth Int. Jt. Conf. on Artificial...interaction through the COUSIN command interface", International Journal of Man- Machine Studies , Vol. 19, No. 3, September 1983, pp. 285-305. 8...in a gracefully interacting user interface," "Dynamic strategy selection in flexible parsing," and "Parsing spoken language: a semantic case frame

  17. Problems in modeling man machine control behavior in biodynamic environments

    NASA Technical Reports Server (NTRS)

    Jex, H. R.

    1972-01-01

    Reviewed are some current problems in modeling man-machine control behavior in a biodynamic environment. It is given in two parts: (1) a review of the models which are appropriate for manual control behavior and the added elements necessary to deal with biodynamic interfaces; and (2) a review of some biodynamic interface pilot/vehicle problems which have occurred, been solved, or need to be solved.

  18. Comparing spatial regression to random forests for large ...

    EPA Pesticide Factsheets

    Environmental data may be “large” due to number of records, number of covariates, or both. Random forests has a reputation for good predictive performance when using many covariates, whereas spatial regression, when using reduced rank methods, has a reputation for good predictive performance when using many records. In this study, we compare these two techniques using a data set containing the macroinvertebrate multimetric index (MMI) at 1859 stream sites with over 200 landscape covariates. Our primary goal is predicting MMI at over 1.1 million perennial stream reaches across the USA. For spatial regression modeling, we develop two new methods to accommodate large data: (1) a procedure that estimates optimal Box-Cox transformations to linearize covariate relationships; and (2) a computationally efficient covariate selection routine that takes into account spatial autocorrelation. We show that our new methods lead to cross-validated performance similar to random forests, but that there is an advantage for spatial regression when quantifying the uncertainty of the predictions. Simulations are used to clarify advantages for each method. This research investigates different approaches for modeling and mapping national stream condition. We use MMI data from the EPA's National Rivers and Streams Assessment and predictors from StreamCat (Hill et al., 2015). Previous studies have focused on modeling the MMI condition classes (i.e., good, fair, and po

  19. Intravenous methimazole in the treatment of refractory hyperthyroidism.

    PubMed

    Hodak, Steven P; Huang, Caroline; Clarke, Donna; Burman, Kenneth D; Jonklaas, Jacqueline; Janicic-Kharic, Natasa

    2006-07-01

    Management of a hyperthyroid patient unable to take oral or rectal medication is a difficult clinical problem. The need for an alternative parenteral route of antithyroid medication administration in thyrotoxic patients occurs in certain rare cases, such as emergent gastrointestinal surgery, bowel ileus or obstruction, or severe vomiting and diarrhea. We report a simple and successful protocol for the preparation and use of intravenous methimazole (MMI) for treatment of hyperthyroidism in patients intolerant of orally and rectally administered thionamides. Five hundred milligrams of methimazole USP powder was reconstituted with pH-neutral 0.9% sodium chloride solution to a final volume of 50 mL using aseptic technique, then filtered through a 0.22-microm filter. MMI injection was administered as a slow intravenous push over 2 minutes and followed by a saline flush. A 76-year-old man, intolerant of oral and rectal medications because of an ileus and intractable diarrhea, who developed worsening thyrotoxicosis after an emergent spinal cord decompression, and a 42-year-old man with chronic liver disease and hyperthyroidism, requiring emergent exploratory laparotomy and maintenance of complete bowel rest because of persistent gastrointestinal bleeding were rendered euthyroid using intravenous MMI. Two cases of hyperthyroidism successfully treated with a preparation of intravenous MMI are described.

  20. Individual differences in media multitasking and performance on the n-back.

    PubMed

    Ralph, Brandon C W; Smilek, Daniel

    2017-02-01

    A number of studies have recently examined the link between individual differences in media multitasking (using the MMI) and performance on working memory paradigms. However, these studies have yielded mixed results. Here we examine the relation between media multitasking and one particular working memory paradigm-the n-back (2- and 3-back)-improving upon previous research by (a) treating media multitasking as a continuous variable and adopting a correlational approach as well as (b) using a large sample of participants. First, we found that higher scores on the MMI were associated with a greater proportion of omitted trials on both the 2-back and 3-back, indicating that heavier media multitaskers were more disengaged during the n-back. In line with such a claim, heavier media multitaskers were also more likely to confess to responding randomly during various portions of the experiment, and to report media multitasking during the experiment itself. Importantly, when controlling for the relation between MMI scores and omissions, higher scores on the MMI were associated with an increase in false alarms, but not with a change in hits. These findings refine the extant literature on media multitasking and working memory performance (specifically, performance on the n-back), and suggest that media multitasking may be related to the propensity to disengage from ongoing tasks.

  1. Combat Automation for Airborne Weapon Systems: Man/Machine Interface Trends and Technologies (L’Automatisation du Combat Aerien: Tendances et Technologies pour l’Interface Homme/Machine)

    DTIC Science & Technology

    1993-04-01

    Homme /Machine) Aocesion For ; 1 [ NTIS ’ D:i: Ü J-H CRA& l TAB 3...I’utilisateur. - Enfm, utilise avec le bouton droit de la souris, le poten- tiom&tre de temps 6coul6 permet de charger une alterna- tive dans le syst&me...a a a a rn£Q £ OB E o 15 l | I? ^©J&Mß) NATO ^ OTAN 7 RUE ANCELLE • 92200 NEUILLY-SÜR-SEINE DIFFUSION DES PUBLICATIONS FRANCE AGARD

  2. Chip breaking system for automated machine tool

    DOEpatents

    Arehart, Theodore A.; Carey, Donald O.

    1987-01-01

    The invention is a rotary selectively directional valve assembly for use in an automated turret lathe for directing a stream of high pressure liquid machining coolant to the interface of a machine tool and workpiece for breaking up ribbon-shaped chips during the formation thereof so as to inhibit scratching or other marring of the machined surfaces by these ribbon-shaped chips. The valve assembly is provided by a manifold arrangement having a plurality of circumferentially spaced apart ports each coupled to a machine tool. The manifold is rotatable with the turret when the turret is positioned for alignment of a machine tool in a machining relationship with the workpiece. The manifold is connected to a non-rotational header having a single passageway therethrough which conveys the high pressure coolant to only the port in the manifold which is in registry with the tool disposed in a working relationship with the workpiece. To position the machine tools the turret is rotated and one of the tools is placed in a material-removing relationship of the workpiece. The passageway in the header and one of the ports in the manifold arrangement are then automatically aligned to supply the machining coolant to the machine tool workpiece interface for breaking up of the chips as well as cooling the tool and workpiece during the machining operation.

  3. Operation of micro and molecular machines: a new concept with its origins in interface science.

    PubMed

    Ariga, Katsuhiko; Ishihara, Shinsuke; Izawa, Hironori; Xia, Hong; Hill, Jonathan P

    2011-03-21

    A landmark accomplishment of nanotechnology would be successful fabrication of ultrasmall machines that can work like tweezers, motors, or even computing devices. Now we must consider how operation of micro- and molecular machines might be implemented for a wide range of applications. If these machines function only under limited conditions and/or require specialized apparatus then they are useless for practical applications. Therefore, it is important to carefully consider the access of functionality of the molecular or nanoscale systems by conventional stimuli at the macroscopic level. In this perspective, we will outline the position of micro- and molecular machines in current science and technology. Most of these machines are operated by light irradiation, application of electrical or magnetic fields, chemical reactions, and thermal fluctuations, which cannot always be applied in remote machine operation. We also propose strategies for molecular machine operation using the most conventional of stimuli, that of macroscopic mechanical force, achieved through mechanical operation of molecular machines located at an air-water interface. The crucial roles of the characteristics of an interfacial environment, i.e. connection between macroscopic dimension and nanoscopic function, and contact of media with different dielectric natures, are also described.

  4. Design of Human-Machine Interface and altering of pelvic obliquity with RGR Trainer.

    PubMed

    Pietrusinski, Maciej; Unluhisarcikli, Ozer; Mavroidis, Constantinos; Cajigas, Iahn; Bonato, Paolo

    2011-01-01

    The Robotic Gait Rehabilitation (RGR) Trainer targets secondary gait deviations in stroke survivors undergoing rehabilitation. Using an impedance control strategy and a linear electromagnetic actuator, the device generates a force field to control pelvic obliquity through a Human-Machine Interface (i.e. a lower body exoskeleton). Herein we describe the design of the RGR Trainer Human-Machine Interface (HMI) and we demonstrate the system's ability to alter the pattern of movement of the pelvis during gait in a healthy subject. Results are shown for experiments during which we induced hip-hiking - in healthy subjects. Our findings indicate that the RGR Trainer has the ability of affecting pelvic obliquity during gait. Furthermore, we provide preliminary evidence of short-term retention of the modified pelvic obliquity pattern induced by the RGR Trainer. © 2011 IEEE

  5. Toward more versatile and intuitive cortical brain-machine interfaces.

    PubMed

    Andersen, Richard A; Kellis, Spencer; Klaes, Christian; Aflalo, Tyson

    2014-09-22

    Brain-machine interfaces have great potential for the development of neuroprosthetic applications to assist patients suffering from brain injury or neurodegenerative disease. One type of brain-machine interface is a cortical motor prosthetic, which is used to assist paralyzed subjects. Motor prosthetics to date have typically used the motor cortex as a source of neural signals for controlling external devices. The review will focus on several new topics in the arena of cortical prosthetics. These include using: recordings from cortical areas outside motor cortex; local field potentials as a source of recorded signals; somatosensory feedback for more dexterous control of robotics; and new decoding methods that work in concert to form an ecology of decode algorithms. These new advances promise to greatly accelerate the applicability and ease of operation of motor prosthetics. Copyright © 2014 Elsevier Ltd. All rights reserved.

  6. Design of Human – Machine Interface and Altering of Pelvic Obliquity with RGR Trainer

    PubMed Central

    Pietrusinski, Maciej; Unluhisarcikli, Ozer; Mavroidis, Constantinos; Cajigas, Iahn; Bonato, Paolo

    2012-01-01

    The Robotic Gait Rehabilitation (RGR) Trainer targets secondary gait deviations in stroke survivors undergoing rehabilitation. Using an impedance control strategy and a linear electromagnetic actuator, the device generates a force field to control pelvic obliquity through a Human-Machine Interface (i.e. a lower body exoskeleton). Herein we describe the design of the RGR Trainer Human-Machine Interface (HMI) and we demonstrate the system’s ability to alter the pattern of movement of the pelvis during gait in a healthy subject. Results are shown for experiments during which we induced hip-hiking – in healthy subjects. Our findings indicate that the RGR Trainer has the ability of affecting pelvic obliquity during gait. Furthermore, we provide preliminary evidence of short-term retention of the modified pelvic obliquity pattern induced by the RGR Trainer. PMID:22275693

  7. 40 CFR 63.464 - Alternative standards.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... (a)(2) of this section. (1) If the cleaning machine has a solvent/air interface, as defined in § 63... cleaning machines 153 New in-line solvent cleaning machines 99 (2) If the cleaning machine is a batch vapor... requirements specified in paragraphs (a)(2)(i) and (a)(2)(ii) of this section. (i) Maintain a log of solvent...

  8. 40 CFR 63.464 - Alternative standards.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... (a)(2) of this section. (1) If the cleaning machine has a solvent/air interface, as defined in § 63... cleaning machines 153 New in-line solvent cleaning machines 99 (2) If the cleaning machine is a batch vapor... requirements specified in paragraphs (a)(2)(i) and (a)(2)(ii) of this section. (i) Maintain a log of solvent...

  9. Assessment of the impact of sea-level rise due to climate change on coastal groundwater discharge.

    PubMed

    Masciopinto, Costantino; Liso, Isabella Serena

    2016-11-01

    An assessment of sea intrusion into coastal aquifers as a consequence of local sea-level rise (LSLR) due to climate change was carried out at Murgia and Salento in southern Italy. The interpolation of sea-level measurements at three tide-gauge stations was performed during the period of 2000 to 2014. The best fit of measurements shows an increasing rate of LSLR ranging from 4.4mm/y to 8.8mm/y, which will result in a maximum LSLR of approximately 2m during the 22nd century. The local rate of sea-level rise matches recent 21st and 22nd century projections of mean global sea-level rise determined by other researchers, which include increased melting rates of the Greenland and Antarctic ice sheets, the effect of ocean thermal expansion, the melting of glaciers and ice caps, and changes in the quantity of stored land water. Subsequently, Ghyben-Herzberg's equation for the freshwater/saltwater interface was rewritten in order to determine the decrease in groundwater discharge due to the maximum LSLR. Groundwater flow simulations and ArcGIS elaborations of digital elevation models of the coast provided input data for the Ghyben-Herzberg calculation under the assumption of head-controlled systems. The progression of seawater intrusion due to LSLR suggests an impressive depletion of available groundwater discharge during the 22nd century, perhaps as much as 16.1% of current groundwater pumping for potable water in Salento. Copyright © 2016 Elsevier B.V. All rights reserved.

  10. MMI-based MOEMS FT spectrometer for visible and IR spectral ranges

    NASA Astrophysics Data System (ADS)

    Al-Demerdash, Bassem M.; Medhat, Mostafa; Sabry, Yasser M.; Saadany, Bassam; Khalil, Diaa

    2014-03-01

    MEMS spectrometers have very strong potential in future healthcare and environmental monitoring applications, where Michelson interferometers are the core optical engine. Recently, MEMS Michelson interferometers based on using silicon interface as a beam splitter (BS) has been proposed [7, 8]. This allows having a monolithically-integrated on-chip FTIR spectrometer. However silicon BS exhibits high absorption loss in the visible range and high material dispersion in the near infrared (NIR) range. For this reason, we propose in this work a novel MOEMS interferometer allowing operation over wider spectral range covering both the infrared (IR) and the visible ranges. The proposed architecture is based on spatial splitting and combining of optical beams using the imaging properties of Multi-Mode Interference MMI waveguide. The proposed structure includes an optical splitter for spatial splitting an input beam into two beams and a combiner for spatial combining the two interferometer beams. A MEMS moveable mirror is provided to produce an optical path difference between the two beams. The new interferometer is fabricated using DRIE technology on an SOI wafer. The movable mirror is metalized and attached to a comb-drive actuator fabricated in the same lithography step in a self-aligned manner on chip. The novel interferometer is tested as a Fourier transform spectrometer. Red laser, IR laser and absorption spectra of different materials are measured with a resolution of 2.5 nm at 635-nm wavelength. The structure is a very compact one that allows its integration and fabrication on a large scale with very low cost.

  11. Man-machine interface requirements - advanced technology

    NASA Technical Reports Server (NTRS)

    Remington, R. W.; Wiener, E. L.

    1984-01-01

    Research issues and areas are identified where increased understanding of the human operator and the interaction between the operator and the avionics could lead to improvements in the performance of current and proposed helicopters. Both current and advanced helicopter systems and avionics are considered. Areas critical to man-machine interface requirements include: (1) artificial intelligence; (2) visual displays; (3) voice technology; (4) cockpit integration; and (5) pilot work loads and performance.

  12. EMG and EPP-integrated human-machine interface between the paralyzed and rehabilitation exoskeleton.

    PubMed

    Yin, Yue H; Fan, Yuan J; Xu, Li D

    2012-07-01

    Although a lower extremity exoskeleton shows great prospect in the rehabilitation of the lower limb, it has not yet been widely applied to the clinical rehabilitation of the paralyzed. This is partly caused by insufficient information interactions between the paralyzed and existing exoskeleton that cannot meet the requirements of harmonious control. In this research, a bidirectional human-machine interface including a neurofuzzy controller and an extended physiological proprioception (EPP) feedback system is developed by imitating the biological closed-loop control system of human body. The neurofuzzy controller is built to decode human motion in advance by the fusion of the fuzzy electromyographic signals reflecting human motion intention and the precise proprioception providing joint angular feedback information. It transmits control information from human to exoskeleton, while the EPP feedback system based on haptic stimuli transmits motion information of the exoskeleton back to the human. Joint angle and torque information are transmitted in the form of air pressure to the human body. The real-time bidirectional human-machine interface can help a patient with lower limb paralysis to control the exoskeleton with his/her healthy side and simultaneously perceive motion on the paralyzed side by EPP. The interface rebuilds a closed-loop motion control system for paralyzed patients and realizes harmonious control of the human-machine system.

  13. Active tactile exploration using a brain-machine-brain interface.

    PubMed

    O'Doherty, Joseph E; Lebedev, Mikhail A; Ifft, Peter J; Zhuang, Katie Z; Shokur, Solaiman; Bleuler, Hannes; Nicolelis, Miguel A L

    2011-10-05

    Brain-machine interfaces use neuronal activity recorded from the brain to establish direct communication with external actuators, such as prosthetic arms. It is hoped that brain-machine interfaces can be used to restore the normal sensorimotor functions of the limbs, but so far they have lacked tactile sensation. Here we report the operation of a brain-machine-brain interface (BMBI) that both controls the exploratory reaching movements of an actuator and allows signalling of artificial tactile feedback through intracortical microstimulation (ICMS) of the primary somatosensory cortex. Monkeys performed an active exploration task in which an actuator (a computer cursor or a virtual-reality arm) was moved using a BMBI that derived motor commands from neuronal ensemble activity recorded in the primary motor cortex. ICMS feedback occurred whenever the actuator touched virtual objects. Temporal patterns of ICMS encoded the artificial tactile properties of each object. Neuronal recordings and ICMS epochs were temporally multiplexed to avoid interference. Two monkeys operated this BMBI to search for and distinguish one of three visually identical objects, using the virtual-reality arm to identify the unique artificial texture associated with each. These results suggest that clinical motor neuroprostheses might benefit from the addition of ICMS feedback to generate artificial somatic perceptions associated with mechanical, robotic or even virtual prostheses.

  14. Sitting in the Pilot's Seat; Optimizing Human-Systems Interfaces for Unmanned Aerial Vehicles

    NASA Technical Reports Server (NTRS)

    Queen, Steven M.; Sanner, Kurt Gregory

    2011-01-01

    One of the pilot-machine interfaces (the forward viewing camera display) for an Unmanned Aerial Vehicle called the DROID (Dryden Remotely Operated Integrated Drone) will be analyzed for optimization. The goal is to create a visual display for the pilot that as closely resembles an out-the-window view as possible. There are currently no standard guidelines for designing pilot-machine interfaces for UAVs. Typically, UAV camera views have a narrow field, which limits the situational awareness (SA) of the pilot. Also, at this time, pilot-UAV interfaces often use displays that have a diagonal length of around 20". Using a small display may result in a distorted and disproportional view for UAV pilots. Making use of a larger display and a camera lens with a wider field of view may minimize the occurrences of pilot error associated with the inability to see "out the window" as in a manned airplane. It is predicted that the pilot will have a less distorted view of the DROID s surroundings, quicker response times and more stable vehicle control. If the experimental results validate this concept, other UAV pilot-machine interfaces will be improved with this design methodology.

  15. A novel wavelength multiplexer/demutiplexer based on side-port multimode interference coupler

    NASA Astrophysics Data System (ADS)

    Wei, Shile; Jian, Wu; Zhao, Lingjuan; Qiu, Jifang; Yin, Zuoshan; Hui, Rongqing

    2014-05-01

    Based on side-port multimode interference coupler, a novel design of 1.31/1.55-μm wavelength multiplexer/demutiplexer on SOI platform with conventional channel waveguides is proposed and analyzed by using wide-angle beam propagation method. With a 25.9μm long ultra-short MMI section, nearly an order of magnitude shorter than that of the previously reported 1.31/1.55-μm wavelength MMI splitters on SOI, simulation results exhibit contrasts of 28dB and 25dB at wavelength 1.31 and 1.55 μm, respectively, and the insertion losses are both below 0.55dB. Meanwhile, the analysis shows that the proposed structure has larger fabrication tolerances than restricted MMI based structures and the present design methodology also applies to split other wavelengths and in different material platforms, such as InP, GaAs and PLC guides, etc.

  16. Temporally and spatially uniform rates of erosion in the southern Appalachian Great Smoky Mountains

    USGS Publications Warehouse

    Matmon, A.; Bierman, P.R.; Larsen, J.; Southworth, S.; Pavich, M.; Caffee, M.

    2003-01-01

    We measured 10Be in fluvial sediment samples (n = 27) from eight Great Smoky Mountain drainages (1-330 km2). Results suggest spatially homogeneous sediment generation (on the 104-105 yr time scale and > 100 km2 spatial scale) at 73 ?? 11 t km-2 yr-1, equivalent to 27 ?? 4 m/m.y. of bedrock erosion. This rate is consistent with rates derived from fission-track, long-term sediment budget, and sediment yield data, all of which indicate that the Great Smoky Mountains and the southern Appalachians eroded during the Mesozoic and Cenozoic at ???30 m/m.y. In contrast, unroofing rates during the Paleozoic orogenic events that formed the Appalachian Mountains were higher (???102 m/m.y.). Erosion rates decreased after termination of tectonically driven uplift, enabling the survival of this ancient mountain belt with its deep crustal root as an isostatically maintained feature in the contemporary landscape.

  17. A case of methimazole-induced hypothyroidism in a patient with endemic goiter: effects of endogenous TSH hyperstimulation after discontinuation of the drug.

    PubMed

    Messina, M; Manieri, C; Spagnuolo, F; Sardi, E; Allegramente, L; Monaco, A; Ciccarelli, E

    1989-04-01

    Serum thyroid hormone and TSH concentrations were monitored in a patient with multinodular endemic goiter and severe methimazole (MMI) induced hypothyrodism up to 190 days after drug withdrawal. Serum concentrations of TT3, TT4 and TSH returned to normal values at the 6th., the 140th, and the 120th. day respectively. Within the first 20 days after MMI withdrawal the increase of serum T3 levels was correlated with the observed decrease of serum TSH concentrations. Successively T3 values decreased and T4 levels progressively increased. Six months after MMI withdrawal basal serum TSH concentration was normal while an exaggerated response to TRH was observed. We think that this peculiar hormone pattern is due to iodine depletion. In this case TSH hyperstimulation increases predominantly T3 secretion demonstrating the reduced thyroidal ability to produce T4 when hyperstimulated.

  18. Slot silicon-gallium nitride waveguide in MMI structures based 1x8 wavelength demultiplexer

    NASA Astrophysics Data System (ADS)

    Ben Zaken, Bar Baruch; Zanzury, Tal; Malka, Dror

    2017-06-01

    We propose a novel 8-channel wavelength multimode interference (MMI) demultiplexer in slot waveguide structures that operated at 1530 nm, 1535 nm, 1540 nm, 1545 nm, 1550 nm, 1555 nm, 1560 nm and 1565 nm wavelengths. Gallium nitride (GaN) surrounded by silicon (Si) was founded as suitable materials for the slot-waveguide structures. The proposed device was designed by seven 1x2 MMI couplers, fourteen S-band and one input taper. Numerical investigations were carried out on the geometrical parameters by using a full vectorial-beam propagation method (FVBPM). Simulation results show that the proposed device can transmit 8-channel that works in the whole C-band (1530- 1565 nm) with low crosstalk ((-19.97)-(-13.77) dB) and bandwidth (1.8-3.6 nm). Thus, the device can be very useful in optical networking systems that work on dense wavelength division multiplexing (DWDM) technology.

  19. Mold Heating and Cooling Pump Package Operator Interface Controls Upgrade

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Josh A. Salmond

    2009-08-07

    The modernization of the Mold Heating and Cooling Pump Package Operator Interface (MHC PP OI) consisted of upgrading the antiquated single board computer with a proprietary operating system to off-the-shelf hardware and off-the-shelf software with customizable software options. The pump package is the machine interface between a central heating and cooling system that pumps heat transfer fluid through an injection or compression mold base on a local plastic molding machine. The operator interface provides the intelligent means of controlling this pumping process. Strict temperature control of a mold allows the production of high quality parts with tight tolerances and lowmore » residual stresses. The products fabricated are used on multiple programs.« less

  20. A Wireless 32-Channel Implantable Bidirectional Brain Machine Interface

    PubMed Central

    Su, Yi; Routhu, Sudhamayee; Moon, Kee S.; Lee, Sung Q.; Youm, WooSub; Ozturk, Yusuf

    2016-01-01

    All neural information systems (NIS) rely on sensing neural activity to supply commands and control signals for computers, machines and a variety of prosthetic devices. Invasive systems achieve a high signal-to-noise ratio (SNR) by eliminating the volume conduction problems caused by tissue and bone. An implantable brain machine interface (BMI) using intracortical electrodes provides excellent detection of a broad range of frequency oscillatory activities through the placement of a sensor in direct contact with cortex. This paper introduces a compact-sized implantable wireless 32-channel bidirectional brain machine interface (BBMI) to be used with freely-moving primates. The system is designed to monitor brain sensorimotor rhythms and present current stimuli with a configurable duration, frequency and amplitude in real time to the brain based on the brain activity report. The battery is charged via a novel ultrasonic wireless power delivery module developed for efficient delivery of power into a deeply-implanted system. The system was successfully tested through bench tests and in vivo tests on a behaving primate to record the local field potential (LFP) oscillation and stimulate the target area at the same time. PMID:27669264

  1. The 26 January 2001 M 7.6 Bhuj, India, earthquake: Observed and predicted ground motions

    USGS Publications Warehouse

    Hough, S.E.; Martin, S.; Bilham, R.; Atkinson, G.M.

    2002-01-01

    Although local and regional instrumental recordings of the devastating 26, January 2001, Bhuj earthquake are sparse, the distribution of macroseismic effects can provide important constraints on the mainshock ground motions. We compiled available news accounts describing damage and other effects and interpreted them to obtain modified Mercalli intensities (MMIs) at >200 locations throughout the Indian subcontinent. These values are then used to map the intensity distribution throughout the subcontinent using a simple mathematical interpolation method. Although preliminary, the maps reveal several interesting features. Within the Kachchh region, the most heavily damaged villages are concentrated toward the western edge of the inferred fault, consistent with western directivity. Significant sediment-induced amplification is also suggested at a number of locations around the Gulf of Kachchh to the south of the epicenter. Away from the Kachchh region, intensities were clearly amplified significantly in areas that are along rivers, within deltas, or on coastal alluvium, such as mudflats and salt pans. In addition, we use fault-rupture parameters inferred from teleseismic data to predict shaking intensity at distances of 0-1000 km. We then convert the predicted hard-rock ground-motion parameters to MMI by using a relationship (derived from Internet-based intensity surveys) that assigns MMI based on the average effects in a region. The predicted MMIs are typically lower by 1-3 units than those estimated from news accounts, although they do predict near-field ground motions of approximately 80%g and potentially damaging ground motions on hard-rock sites to distances of approximately 300 km. For the most part, this discrepancy is consistent with the expected effect of sediment response, but it could also reflect other factors, such as unusually high building vulnerability in the Bhuj region and a tendency for media accounts to focus on the most dramatic damage, rather than the average effects. The discrepancy may also be partly attributable to the inadequacy of the empirical relationship between MMI and peak ground acceleration (PGA), when applied to India. The MMI-PGA relationship was developed using data from California earthquakes, which might have a systematically different stress drop and therefore, a different frequency content than intraplate events. When a relationship between response spectra and MMI is used, we obtain larger predicted MMI values, in better agreement with the observations.

  2. Materials and optimized designs for human-machine interfaces via epidermal electronics.

    PubMed

    Jeong, Jae-Woong; Yeo, Woon-Hong; Akhtar, Aadeel; Norton, James J S; Kwack, Young-Jin; Li, Shuo; Jung, Sung-Young; Su, Yewang; Lee, Woosik; Xia, Jing; Cheng, Huanyu; Huang, Yonggang; Choi, Woon-Seop; Bretl, Timothy; Rogers, John A

    2013-12-17

    Thin, soft, and elastic electronics with physical properties well matched to the epidermis can be conformally and robustly integrated with the skin. Materials and optimized designs for such devices are presented for surface electromyography (sEMG). The findings enable sEMG from wide ranging areas of the body. The measurements have quality sufficient for advanced forms of human-machine interface. © 2013 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  3. My thoughts through a robot's eyes: an augmented reality-brain-machine interface.

    PubMed

    Kansaku, Kenji; Hata, Naoki; Takano, Kouji

    2010-02-01

    A brain-machine interface (BMI) uses neurophysiological signals from the brain to control external devices, such as robot arms or computer cursors. Combining augmented reality with a BMI, we show that the user's brain signals successfully controlled an agent robot and operated devices in the robot's environment. The user's thoughts became reality through the robot's eyes, enabling the augmentation of real environments outside the anatomy of the human body.

  4. A Tool for Assessing the Text Legibility of Digital Human Machine Interfaces

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Roger Lew; Ronald L. Boring; Thomas A. Ulrich

    2015-08-01

    A tool intended to aid qualified professionals in the assessment of the legibility of text presented on a digital display is described. The assessment of legibility is primarily for the purposes of designing and analyzing human machine interfaces in accordance with NUREG-0700 and MIL-STD 1472G. The tool addresses shortcomings of existing guidelines by providing more accurate metrics of text legibility with greater sensitivity to design alternatives.

  5. Mobile Tactical HF/VHF/EW System for Ground Forces

    DTIC Science & Technology

    1989-09-01

    presen- tation of what I have learned . I would like to thank my advisor, Professor Robert Partelow, and co-advisor, Commander James R. Powell, for the...analyze newly developed systems to determine how the man- machine interfaces of such systems can best be designed for optimal use by the operators. B...terminals and other controls. If factors like luminance ratio, reflectance, glare illuminance are allowed for good man- machine interface then an effective

  6. Reverse-micelle-induced porous pressure-sensitive rubber for wearable human-machine interfaces.

    PubMed

    Jung, Sungmook; Kim, Ji Hoon; Kim, Jaemin; Choi, Suji; Lee, Jongsu; Park, Inhyuk; Hyeon, Taeghwan; Kim, Dae-Hyeong

    2014-07-23

    A novel method to produce porous pressure-sensitive rubber is developed. For the controlled size distribution of embedded micropores, solution-based procedures using reverse micelles are adopted. The piezosensitivity of the pressure sensitive rubber is significantly increased by introducing micropores. Using this method, wearable human-machine interfaces are fabricated, which can be applied to the remote control of a robot. © 2014 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  7. Decoding the non-stationary neuron spike trains by dual Monte Carlo point process estimation in motor Brain Machine Interfaces.

    PubMed

    Liao, Yuxi; Li, Hongbao; Zhang, Qiaosheng; Fan, Gong; Wang, Yiwen; Zheng, Xiaoxiang

    2014-01-01

    Decoding algorithm in motor Brain Machine Interfaces translates the neural signals to movement parameters. They usually assume the connection between the neural firings and movements to be stationary, which is not true according to the recent studies that observe the time-varying neuron tuning property. This property results from the neural plasticity and motor learning etc., which leads to the degeneration of the decoding performance when the model is fixed. To track the non-stationary neuron tuning during decoding, we propose a dual model approach based on Monte Carlo point process filtering method that enables the estimation also on the dynamic tuning parameters. When applied on both simulated neural signal and in vivo BMI data, the proposed adaptive method performs better than the one with static tuning parameters, which raises a promising way to design a long-term-performing model for Brain Machine Interfaces decoder.

  8. Finite element analysis when orthogonal cutting of hybrid composite CFRP/Ti

    NASA Astrophysics Data System (ADS)

    Xu, Jinyang; El Mansori, Mohamed

    2015-07-01

    Hybrid composite, especially CFRP/Ti stack, is usually considered as an innovative structural configuration for manufacturing the key load-bearing components in modern aerospace industry. This paper originally proposed an FE model to simulate the total chip formation process dominated the hybrid cutting operation. The hybrid composite model was established based on three physical constituents, i.e., Ti constituent, interface and CFRP constituent. Different constitutive models and damage criteria were introduced to replicate the interrelated cutting behaviour of the stack material. The CFRP/Ti interface was modelled as a third phase through the concept of cohesive zone (CZ). Particular attention was made on the comparative studies of the influence of different cutting-sequence strategies on the machining responses induced in hybrid stack cutting. The numerical results emphasized the pivotal role of cutting-sequence strategy on the various machining induced responses including cutting-force generation, machined surface quality and induced interface damage.

  9. Compatibility Problems of Network Interfacing.

    ERIC Educational Resources Information Center

    Stevens, Mary Elizabeth

    From the standpoint of information network technology there is a necessary emphasis upon compatibility requirements which, in turn, will be met at least in part by various techniques of achieving convertibility --- between machine and machine, between man and machine, and between man and man. It may be hoped that improved compatibilities between…

  10. Modified Mercalli intensity assignments for the May 16, 1909, Northern Plains earthquake

    USGS Publications Warehouse

    Bakun, W.H.; Stickney, M.C.; Rogers, G.; Ristau, J.

    2010-01-01

    We use newspaper accounts from the United States and Canada to assign modified Mercalli intensity (MMI) at 90 towns for the May 16, 1909 Northern Plains earthquake. Our MMI assignments generally are consistent with those plotted on Nuttli's (1976) isoseiemal map. The earthquake was felt over more than 1,500,000 km2 in the states of Minnesota, Montana, North Dakota, South Dakota, and Wyoming and the provinces of Alberta, Manitoba, Ontario, and Saskatchewan.

  11. gene GIS: Computational Tools for Spatial Analyses of DNA Profiles with Associated Photo-Identification and Telemetry Records of Marine Mammals

    DTIC Science & Technology

    2011-09-30

    DNA profiles. Referred to as geneGIS, the program will provide the ability to display, browse, select, filter and summarize spatial or temporal...of the SPLASH photo-identification records and available DNA profiles is underway through integration and crosschecking by Cascadia and MMI . An...Darwin Core standards where possible and can accommodate the current databases developed for telemetry data at MMI and SPLASH collection records at

  12. geneGIS: Computational Tools for Spatial Analyses of DNA Profiles with Associated Photo-Identification and Telemetry Records of Marine Mammals

    DTIC Science & Technology

    2012-09-30

    computational tools provide the ability to display, browse, select, filter and summarize spatio-temporal relationships of these individual-based...her research assistant at Esri, Shaun Walbridge, and members of the Marine Mammal Institute ( MMI ), including Tomas Follet and Debbie Steel. This...Genomics Laboratory, MMI , OSU. 4 As part of the geneGIS initiative, these SPLASH photo-identification records and the geneSPLASH DNA profiles

  13. Comparability among four invertebrate sampling methods and two multimetric indexes, Fountain Creek Basin, Colorado, 2010–2012

    USGS Publications Warehouse

    Bruce, James F.; Roberts, James J.; Zuellig, Robert E.

    2018-05-24

    The U.S. Geological Survey (USGS), in cooperation with Colorado Springs City Engineering and Colorado Springs Utilities, analyzed previously collected invertebrate data to determine the comparability among four sampling methods and two versions (2010 and 2017) of the Colorado Benthic Macroinvertebrate Multimetric Index (MMI). For this study, annual macroinvertebrate samples were collected concurrently (in space and time) at 15 USGS surface-water gaging stations in the Fountain Creek Basin from 2010 to 2012 using four sampling methods. The USGS monitoring project in the basin uses two of the methods and the Colorado Department of Public Health and Environment recommends the other two. These methods belong to two distinct sample types, one that targets single habitats and one that targets multiple habitats. The study results indicate that there are significant differences in MMI values obtained from the single-habitat and multihabitat sample types but methods from each program within each sample type produced comparable values. This study also determined that MMI values calculated by different versions of the Colorado Benthic Macroinvertebrate MMI are indistinguishable. This indicates that the Colorado Department of Public Health and Environment methods are comparable with the USGS monitoring project methods for single-habitat and multihabitat sample types. This report discusses the direct application of the study results to inform the revision of the existing USGS monitoring project in the Fountain Creek Basin.

  14. Unusual Synchronous Methimazole-Induced Agranulocytosis and Severe Hepatotoxicity in Patient with Hyperthyroidism: A Case Report and Review of the Literature

    PubMed Central

    Yang, Jun; Zhang, Jun; Xu, Qin; Sheng, Guo-ping; Weng, Wan-wen; Dong, Meng-jie

    2015-01-01

    Context. To report a patient with hyperthyroidism who developed concurrent occurrence of agranulocytosis and severe hepatotoxicity after taking methimazole (MMI). Case. A 51-year-old Chinese male was diagnosed as hyperthyroidism with normal white blood count and liver function. After 4 weeks' treatment with MMI 20 mg/d, it developed to agranulocytosis and severe cholestatic hepatotoxicity. The patient's symptoms and laboratory abnormalities disappeared after the withdrawal of MMI; his white blood count and liver function recover to normal in 2 weeks and 5 weeks, respectively. 296 MBq dose of 131I was given to the patient 3 weeks after the withdrawal of MMI and his thyroid function was back to normal in 6 months. As we know through literature review, only 5 previous cases reported the synchronous ATD-induced agranulocytosis and severe hepatotoxicity in patients with hyperthyroidism. Methods. Review of the patient's clinical course. Literature review of cases of hyperthyroidism with agranulocytosis and severe hepatotoxicity demonstrated that these complications occurred after taking antithyroid drug (ATD). Conclusions. Patient with hyperthyroidism can have synchronous ATD-induced agranulocytosis and severe hepatotoxicity. This case is extremely rare, but the adverse effects with ATDs is clinically significant. The clinicians need to be careful about this and monitor biochemical of patients who take ATDs. PMID:26060496

  15. Development of a thyroperoxidase inhibition assay for high ...

    EPA Pesticide Factsheets

    High-throughput screening (HTPS) assays to detect inhibitors of thyroperoxidase (TPO), the enzymatic catalyst for thyroid hormone (TH) synthesis, are not currently available. Herein we describe the development of a HTPS TPO inhibition assay. Rat thyroid microsomes and a fluorescent peroxidase substrate, Amplex UltraRed (AUR, LifeTechnologies), were employed in an endpoint assay for comparison to the existing kinetic guaiacol (GUA) oxidation assay. Following optimization of assay metrics including Z’, dynamic range, and activity using methimazole (MMI), the assay was tested with a 21-chemical training set. The potency of MMI-induced TPO inhibition was greater with AUR compared to GUA. The dynamic range and Z’ score with MMI were as follows: 127-fold and 0.62 for the GUA assay, 18-fold and 0.86 for the 96-well AUR assay, and 11.5-fold and 0.93 for the 384-well AUR assay. The 384-well AUR assay drastically reduced animal use, requiring one-tenth of the rat thyroid microsomal protein needed for the GUA 96-well format assay. Fourteen chemicals inhibited TPO, with a relative potency ranking of MMI > ethylene thiourea > 6-propylthiouracil > 2,2’,4,4’-tetrahydroxy-benzophenone > 2-mercaptobenzothiazole > 3-amino-1,2,4-triazole > genistein > 4-propoxyphenol > sulfamethazine > daidzein > 4-nonylphenol > triclosan > iopanoic acid > resorcinol. These data demonstrate the capacity of this assay to detect diverse TPO inhibitors. Seven chemicals acted as negati

  16. Gesture-Controlled Interfaces for Self-Service Machines

    NASA Technical Reports Server (NTRS)

    Cohen, Charles J.; Beach, Glenn

    2006-01-01

    Gesture-controlled interfaces are software- driven systems that facilitate device control by translating visual hand and body signals into commands. Such interfaces could be especially attractive for controlling self-service machines (SSMs) for example, public information kiosks, ticket dispensers, gasoline pumps, and automated teller machines (see figure). A gesture-controlled interface would include a vision subsystem comprising one or more charge-coupled-device video cameras (at least two would be needed to acquire three-dimensional images of gestures). The output of the vision system would be processed by a pure software gesture-recognition subsystem. Then a translator subsystem would convert a sequence of recognized gestures into commands for the SSM to be controlled; these could include, for example, a command to display requested information, change control settings, or actuate a ticket- or cash-dispensing mechanism. Depending on the design and operational requirements of the SSM to be controlled, the gesture-controlled interface could be designed to respond to specific static gestures, dynamic gestures, or both. Static and dynamic gestures can include stationary or moving hand signals, arm poses or motions, and/or whole-body postures or motions. Static gestures would be recognized on the basis of their shapes; dynamic gestures would be recognized on the basis of both their shapes and their motions. Because dynamic gestures include temporal as well as spatial content, this gesture- controlled interface can extract more information from dynamic than it can from static gestures.

  17. Analysis of 90 cases of antithyroid drug-induced severe hepatotoxicity over 13 years in China.

    PubMed

    Yang, Jun; Li, Lin-Fa; Xu, Qin; Zhang, Jun; Weng, Wan-Wen; Zhu, Yang-Jun; Dong, Meng-Jie

    2015-03-01

    Antithyroid drug (ATD)-induced severe hepatotoxicity is a rare but serious complication of ATD therapy. The characteristics of severe hepatotoxicity have been reported in only a small number of patients. Ninety patients with ATD-induced severe hepatotoxicity presenting during a 13 year period (2000-2013) who were about to undergo nuclear medicine therapy with (131)I from a sample of 8864 patients with hyperthyroidism were studied, and the outcomes were evaluated. The mean age of the patients with ATD-induced severe hepatotoxicity was 41.6±12.5 years (mean±standard deviation), and the female to male ratio was 2.2:1. The methimazole (MMI) dose given at the onset was 19.1±7.4 mg/day. The propylthiouracil (PTU) dose given at the onset was 212.8±105.0 mg/day. ATD-induced severe hepatotoxicity occurred in 63.3%, 75.6%, and 81.1% of patients within 4, 8, and 12 weeks of the onset of ATD therapy, respectively. The types of severe hepatotoxicity did not differ significantly between the MMI and PTU groups (p=0.188). The frequency of the cholestatic type in the MMI group (35.3%, 18/51) was higher than that in the PTU group (17.9%, 7/39), but these frequencies were not significantly different (p=0.069). The patients who were treated with (131)I received an average dose of 279.1±86.1 MBq (n=84). Therapy was successful in 60 of the 67 patients (89.6%). The success rate was equivalent (p=0.696) between the groups receiving MMI (91.7%, 33/36) and PTU (87.1%, 27/31). Severe hepatotoxicity tends to occur within the first three months after the onset of ATD therapy. The type of ATD-induced severe hepatotoxicity did not differ between the MMI and PTU groups. (131)I therapy is an effective treatment approach for patients with ATD-induced severe hepatotoxicity.

  18. Human-machine interface hardware: The next decade

    NASA Technical Reports Server (NTRS)

    Marcus, Elizabeth A.

    1991-01-01

    In order to understand where human-machine interface hardware is headed, it is important to understand where we are today, how we got there, and what our goals for the future are. As computers become more capable, faster, and programs become more sophisticated, it becomes apparent that the interface hardware is the key to an exciting future in computing. How can a user interact and control a seemingly limitless array of parameters effectively? Today, the answer is most often a limitless array of controls. The link between these controls and human sensory motor capabilities does not utilize existing human capabilities to their full extent. Interface hardware for teleoperation and virtual environments is now facing a crossroad in design. Therefore, we as developers need to explore how the combination of interface hardware, human capabilities, and user experience can be blended to get the best performance today and in the future.

  19. Who Needs to Fit In? Who Gets to Stand Out? Communication Technologies Including Brain-Machine Interfaces Revealed from the Perspectives of Special Education School Teachers through an Ableism Lens

    ERIC Educational Resources Information Center

    Diep, Lucy; Wolbring, Gregor

    2013-01-01

    Some new and envisioned technologies such as brain machine interfaces (BMI) that are being developed initially for people with disabilities, but whose use can also be expanded to the general public have the potential to change body ability expectations of disabled and non-disabled people beyond the species-typical. The ways in which this dynamic…

  20. Body-Machine Interfaces after Spinal Cord Injury: Rehabilitation and Brain Plasticity.

    PubMed

    Seáñez-González, Ismael; Pierella, Camilla; Farshchiansadegh, Ali; Thorp, Elias B; Wang, Xue; Parrish, Todd; Mussa-Ivaldi, Ferdinando A

    2016-12-19

    The purpose of this study was to identify rehabilitative effects and changes in white matter microstructure in people with high-level spinal cord injury following bilateral upper-extremity motor skill training. Five subjects with high-level (C5-C6) spinal cord injury (SCI) performed five visuo-spatial motor training tasks over 12 sessions (2-3 sessions per week). Subjects controlled a two-dimensional cursor with bilateral simultaneous movements of the shoulders using a non-invasive inertial measurement unit-based body-machine interface. Subjects' upper-body ability was evaluated before the start, in the middle and a day after the completion of training. MR imaging data were acquired before the start and within two days of the completion of training. Subjects learned to use upper-body movements that survived the injury to control the body-machine interface and improved their performance with practice. Motor training increased Manual Muscle Test scores and the isometric force of subjects' shoulders and upper arms. Moreover, motor training increased fractional anisotropy (FA) values in the cingulum of the left hemisphere by 6.02% on average, indicating localized white matter microstructure changes induced by activity-dependent modulation of axon diameter, myelin thickness or axon number. This body-machine interface may serve as a platform to develop a new generation of assistive-rehabilitative devices that promote the use of, and that re-strengthen, the motor and sensory functions that survived the injury.

  1. A new design approach to MMI-based (de)multiplexers

    NASA Astrophysics Data System (ADS)

    Yueyu, Xiao; Sailing, He

    2004-09-01

    A novel design method of the wavelength (de)multiplexer is presented. The output spectral response of a (de)multiplexer is designed from the view of FIR filters. Avoiding laborious mathematic analysis, the (de)multiplexer is analyzed and designed in this explicit and simple method. A four channel (de)multiplexer based on multimode interference (MMI) is designed as an example. The result obtained agrees with that of the commonly used method, and is verified by a finite difference beam propagation method (FDBPM) simulation.

  2. Classification VIA Information-Theoretic Fusion of Vector-Magnetic and Acoustic Sensor Data

    DTIC Science & Technology

    2007-04-01

    10) where tBsBtBsBtBsBtsB zzyyxx, . (11) The operation in (10) may be viewed as a vector matched- filter on to estimate )(tB CPARv . In summary...choosing to maximize the classification information in Y are described in Section 3.2. A 3.2. Maximum mutual information ( MMI ) features We begin with a...review of several desirable properties of features that maximize a mutual information ( MMI ) criterion. Then we review a particular algorithm [2

  3. Towards Intelligent Environments: An Augmented Reality–Brain–Machine Interface Operated with a See-Through Head-Mount Display

    PubMed Central

    Takano, Kouji; Hata, Naoki; Kansaku, Kenji

    2011-01-01

    The brain–machine interface (BMI) or brain–computer interface is a new interface technology that uses neurophysiological signals from the brain to control external machines or computers. This technology is expected to support daily activities, especially for persons with disabilities. To expand the range of activities enabled by this type of interface, here, we added augmented reality (AR) to a P300-based BMI. In this new system, we used a see-through head-mount display (HMD) to create control panels with flicker visual stimuli to support the user in areas close to controllable devices. When the attached camera detects an AR marker, the position and orientation of the marker are calculated, and the control panel for the pre-assigned appliance is created by the AR system and superimposed on the HMD. The participants were required to control system-compatible devices, and they successfully operated them without significant training. Online performance with the HMD was not different from that using an LCD monitor. Posterior and lateral (right or left) channel selections contributed to operation of the AR–BMI with both the HMD and LCD monitor. Our results indicate that AR–BMI systems operated with a see-through HMD may be useful in building advanced intelligent environments. PMID:21541307

  4. Proceedings of the Annual Seminar (First), ’The Art of Communications Interfaces’, Held at Fort Monmouth, New Jersey on 22 April 1976,

    DTIC Science & Technology

    Both the oldest and the newest problem areas in communications electronics interfaces are discussed in conjunction with the currently critical...digital communication system evolution. The oldest interface problem, still the most essential is the man machine communications interfaces. The newest is

  5. Effect of time variation on coating characteristic of Ti-6Al-4V alloy coated with TiO2 by dip coating method

    NASA Astrophysics Data System (ADS)

    Hashim Aneed, Shaymaa

    2018-05-01

    In this reserch samples of Ti-6Al-4V alloy was coated with TiO2 layer by dip coating method in solution consist of 8 gm TiO2 nanoparticle dissolved in 100 ml. ethanol absolute (99%) and 1 gm P2O5, with various coating periods (1,2,3) minuts. The corrosion characteristics was investigated using (parstat 2273,USA made),the corrosion rate reach to 7.047 × 10-4 mm/y for sample coated at 3 minutes compared with 8.266 × 10-3mm/y for uncoated sample. Then the samples immersed in simulated body fluid (SBF) synthesized in the laboratory for one month in order to investigate the osseointegration from hydroxyapatite biomimatically formed, the corrosion charactaristics also invistigated after immirsing in (SBF) and it was 1.479 × 10-4 mm/y. For each part of reaserch we test the optical microscopic images,XRD and SEM in order to evaluate the results.

  6. Multi-monochromatic imaging of defect-induced mix experiments at OMEGA

    NASA Astrophysics Data System (ADS)

    Mancini, Roberto; Johns, Heather; Joshi, Tirtha; Mayes, Daniel; Durmaz, Tunay; Nagayama, Taisuke; Hsu, Scott; Tregillis, Ian; Krasheninnikova, Natalia; Cobble, James; Murphy, Thomas; Shah, Rahul; Kyrala, George; Hakel, Peter; Bradley, Paul; Schmitt, Mark

    2012-10-01

    In a series of polar-drive implosions performed at OMEGA for the defect-induced mix experiment (DIME) campaign of Los Alamos National Laboratory, two identical multi-monochromatic imager (MMI) instruments were fielded to record gated, x-ray spectrally-resolved images of D-filled Ti-doped plastic shells. The shells included a defect on the equatorial plane to study defect-induced mix while no-defect shells were employed in reference shots. The MMI data recorded simultaneously along quasi-orthogonal lines-of-sight afforded unique observations of the implosion based on the K-shell spectral signatures of the Ti tracer. Several analysis techniques have been used to process the MMI data (T. Nagayama et al, J. App. Phys. 109, 093303 (2011)) in order to study defect-induced mixing by tracking the spatial distribution and state of the tracer. Comparisons were made with results from post-processed 2D and 3D simulations to provide further insight into the interpretation of the experimental results and to constrain the simulation physics model.

  7. Bi-directional triplexer with butterfly MMI coupler using SU-8 polymer waveguides

    NASA Astrophysics Data System (ADS)

    Mareš, David; Jeřábek, Vítězslav; Prajzler, Václav

    2015-01-01

    We report about a design of a bi-directional planar optical multiplex/demultiplex filter (triplexer) for the optical part of planar hybrid WDM bi-directional transceiver in fiber-to-the-home (FTTH) PON applications. The triplex lightwave circuit is based on the Epoxy Novolak Resin SU-8 waveguides on the silica-on-silicon substrate with Polymethylmethacrylate cladding layer. The triplexer is comprised of a linear butterfly concept of multimode interference (MMI) coupler separating downstream optical signals of 1490 nm and 1550 nm. For the upstream channel of 1310 nm, an additional directional coupler (DC) is used to add optical signal of 1310 nm propagating in opposite direction. The optical triplexer was designed and optimized using beam propagation method. The insertion losses, crosstalk attenuation, and extinction ratio for all three inputs/outputs were investigated. The intended triplexer was designed using the parameters of the separated DC and MMI filter to approximate the idealized direct connection of both devices.

  8. Resolution improvement in positron emission tomography using anatomical Magnetic Resonance Imaging.

    PubMed

    Chu, Yong; Su, Min-Ying; Mandelkern, Mark; Nalcioglu, Orhan

    2006-08-01

    An ideal imaging system should provide information with high-sensitivity, high spatial, and temporal resolution. Unfortunately, it is not possible to satisfy all of these desired features in a single modality. In this paper, we discuss methods to improve the spatial resolution in positron emission imaging (PET) using a priori information from Magnetic Resonance Imaging (MRI). Our approach uses an image restoration algorithm based on the maximization of mutual information (MMI), which has found significant success for optimizing multimodal image registration. The MMI criterion is used to estimate the parameters in the Sharpness-Constrained Wiener filter. The generated filter is then applied to restore PET images of a realistic digital brain phantom. The resulting restored images show improved resolution and better signal-to-noise ratio compared to the interpolated PET images. We conclude that a Sharpness-Constrained Wiener filter having parameters optimized from a MMI criterion may be useful for restoring spatial resolution in PET based on a priori information from correlated MRI.

  9. Corrosion control when using passively treated abandoned mine drainage as alternative makeup water for cooling systems.

    PubMed

    Hsieh, Ming-Kai; Chien, Shih-Hsiang; Li, Heng; Monnell, Jason D; Dzombak, David A; Vidic, Radisav D

    2011-09-01

    Passively treated abandoned mine drainage (AMD) is a promising alternative to fresh water as power plant cooling water system makeup water in mining regions where such water is abundant. Passive treatment and reuse of AMD can avoid the contamination of surface water caused by discharge of abandoned mine water, which typically is acidic and contains high concentrations of metals, especially iron. The purpose of this study was to evaluate the feasibility of reusing passively treated AMD in cooling systems with respect to corrosion control through laboratory experiments and pilot-scale field testing. The results showed that, with the addition of the inhibitor mixture orthophosphate and tolyltriazole, mild steel and copper corrosion rates were reduced to acceptable levels (< 0.127 mm/y and < 0.0076 mm/y, respectively). Aluminum had pitting corrosion problems in every condition tested, while cupronickel showed that, even in the absence of any inhibitor and in the presence of the biocide monochloramine, its corrosion rate was still very low (0.018 mm/y).

  10. A Machine Learning and Optimization Toolkit for the Swarm

    DTIC Science & Technology

    2014-11-17

    Machine   Learning  and  Op0miza0on   Toolkit  for  the  Swarm   Ilge  Akkaya,  Shuhei  Emoto...3. DATES COVERED 00-00-2014 to 00-00-2014 4. TITLE AND SUBTITLE A Machine Learning and Optimization Toolkit for the Swarm 5a. CONTRACT NUMBER... machine   learning   methodologies  by  providing  the  right  interfaces  between   machine   learning  tools  and

  11. Object Management Group object transaction service based on an X/Open and International Organization for Standardization open systems interconnection transaction processing kernel

    NASA Astrophysics Data System (ADS)

    Liang, J.; Sédillot, S.; Traverson, B.

    1997-09-01

    This paper addresses federation of a transactional object standard - Object Management Group (OMG) object transaction service (OTS) - with the X/Open distributed transaction processing (DTP) model and International Organization for Standardization (ISO) open systems interconnection (OSI) transaction processing (TP) communication protocol. The two-phase commit propagation rules within a distributed transaction tree are similar in the X/Open, ISO and OMG models. Building an OTS on an OSI TP protocol machine is possible because the two specifications are somewhat complementary. OTS defines a set of external interfaces without specific internal protocol machine, while OSI TP specifies an internal protocol machine without any application programming interface. Given these observations, and having already implemented an X/Open two-phase commit transaction toolkit based on an OSI TP protocol machine, we analyse the feasibility of using this implementation as a transaction service provider for OMG interfaces. Based on the favourable result of this feasibility study, we are implementing an OTS compliant system, which, by initiating the extensibility and openness strengths of OSI TP, is able to provide interoperability between X/Open DTP and OMG OTS models.

  12. AIMSsim Version 2.3.4 - User Manual

    DTIC Science & Technology

    2008-01-01

    sera en mesure d’utiliser le système efficacement et moyennant une formation minimale, un prototype d’interface humain -machine (IHM) a été développé...d’utiliser l’ensemble de capteurs efficacement et moyennant une formation minimale, un prototype d’interface humain -machine (IHM) a été développé pour...recherche AIMSsim offrent à l’expérimentateur un niveau de simulation assez détaillé pour mener des analyses du rendement humain , qui fournissent à

  13. Image understanding and the man-machine interface II; Proceedings of the Meeting, Los Angeles, CA, Jan. 17, 18, 1989

    NASA Technical Reports Server (NTRS)

    Barrett, Eamon B. (Editor); Pearson, James J. (Editor)

    1989-01-01

    Image understanding concepts and models, image understanding systems and applications, advanced digital processors and software tools, and advanced man-machine interfaces are among the topics discussed. Particular papers are presented on such topics as neural networks for computer vision, object-based segmentation and color recognition in multispectral images, the application of image algebra to image measurement and feature extraction, and the integration of modeling and graphics to create an infrared signal processing test bed.

  14. Peat in the ?Niayes? of Senegal: depositional environment and Holocene evolution

    NASA Astrophysics Data System (ADS)

    Lézine, A.-M.; Chateauneuf, J.-J.

    The "Niayes" peat deposits north of Dakar, in Senegal, provide an unusual opportunity to study the continental and littoral detrital environment of the Holocene in West Africa. These organic deposits, that may attain a thickness of 10m, accumulated in Late Pleistocene interdune basins whose extend morphology depend closely upon the palaeohydrologic evolution of and the continental model for this zone during the Holocene. The present sub-Canarian climate of this region allows the preservation of an azonal vegetation of Guinean chorological affinity that is evidence of the wider development of now more southerly vegetation during the older Holocene. The nature of the sedimentary facies of these peatfields is closely related to the altitude of the basins of accumulation and the position of the fresh/salt water interface which conditions the recharge of the shallow aquifer. Thus, fresh-water and mangrove-swamp peats exist more or less closely associated according to the site. 14C age determinations gives ages for these deposits between 12000 B.P. and the present, and detailed palynological studies have shown that there were two periods of climatic optimum, one between 9000 and 7000 B.P. and one between 4000 and 2000 B.P. The highly variable rates of sedimentation (0.2-12,5 mm/y for the continental zones and 2 mm/y for the mangrove swamps) are related to the paleotopography of the water-table or to very local fluctuations of sea level. The evolution of the vegetal biomass, evaluated both qualitatively (relative representation of the various vegetation levels) and quantitatively (concentration of pollen per gram of dry sediment) during the course of the Holocene enables reconstruction of the complete climatic and hydrologic history of the region up to the dawn of the Present.

  15. A Natural Language Interface to Databases

    NASA Technical Reports Server (NTRS)

    Ford, D. R.

    1990-01-01

    The development of a Natural Language Interface (NLI) is presented which is semantic-based and uses Conceptual Dependency representation. The system was developed using Lisp and currently runs on a Symbolics Lisp machine.

  16. Congenital anomalies in children exposed to antithyroid drugs in-utero: a meta-analysis of cohort studies.

    PubMed

    Li, Huixia; Zheng, Jianfei; Luo, Jiayou; Zeng, Rong; Feng, Na; Zhu, Na; Feng, Qi

    2015-01-01

    Hyperthyroidism affects about 0.2%-2.7% of all pregnancies, and is commonly managed with antithyroid drugs (ATDs). However, previous studies about the effects of ATDs on congenital anomalies are controversial. Therefore, the present meta-analysis was performed to explore the risk of congenital anomalies in children exposed to ATDs in-utero. Embase, Pubmed, Web of Knowledge, and BIOSIS Citation Index were searched to find out studies about congenital anomalies in children exposed to ATDs in-utero reported up to May 2014. The references cited by the retrieved articles were also searched. The relative risks (RRs) and confidence intervals (CIs) for the individual studies were pooled by fixed effects models, and heterogeneity was analyzed by chi-square and I2 tests. Eight studies met the inclusion criteria. Exposure to propylthiouracil (PTU), methimazole/carbimazole (MMI/CMZ), and PTU & MMI/CMZ was investigated in 7, 7 and 2 studies, respectively. The pooled RR was 1.20 (95%CI: 1.02-1.42), 1.64 (95%CI: 1.39-1.92), and 1.83 (95%CI: 1.30-2.56) for congenital anomalies after exposure to PTU, MMI/CMZ, and PTU & MMI/CMZ, respectively. The meta-analysis suggests that exposure to ATDs in-utero increases the risk of congenital anomalies. The use of ATDs in pregnancy should be limited when possible. Further research is needed to delineate the exact teratogenic risk for particular congenital anomaly.

  17. Congenital Anomalies in Children Exposed to Antithyroid Drugs In-Utero: A Meta-Analysis of Cohort Studies

    PubMed Central

    Luo, Jiayou; Zeng, Rong; Feng, Na; Zhu, Na; Feng, Qi

    2015-01-01

    Background Hyperthyroidism affects about 0.2%-2.7% of all pregnancies, and is commonly managed with antithyroid drugs (ATDs). However, previous studies about the effects of ATDs on congenital anomalies are controversial. Therefore, the present meta-analysis was performed to explore the risk of congenital anomalies in children exposed to ATDs in-utero. Methods Embase, Pubmed, Web of Knowledge, and BIOSIS Citation Index were searched to find out studies about congenital anomalies in children exposed to ATDs in-utero reported up to May 2014. The references cited by the retrieved articles were also searched. The relative risks (RRs) and confidence intervals (CIs) for the individual studies were pooled by fixed effects models, and heterogeneity was analyzed by chi-square and I 2 tests. Results Eight studies met the inclusion criteria. Exposure to propylthiouracil (PTU), methimazole/carbimazole (MMI/CMZ), and PTU & MMI/CMZ was investigated in 7, 7 and 2 studies, respectively. The pooled RR was 1.20 (95%CI: 1.02-1.42), 1.64 (95%CI: 1.39-1.92), and 1.83 (95%CI: 1.30-2.56) for congenital anomalies after exposure to PTU, MMI/CMZ, and PTU & MMI/CMZ, respectively. Conclusions The meta-analysis suggests that exposure to ATDs in-utero increases the risk of congenital anomalies. The use of ATDs in pregnancy should be limited when possible. Further research is needed to delineate the exact teratogenic risk for particular congenital anomaly. PMID:25974033

  18. Using Modified Mercalli Intensities to estimate acceleration response spectra for the 1906 San Francisco earthquake

    USGS Publications Warehouse

    Boatwright, J.; Bundock, H.; Seekins, L.C.

    2006-01-01

    We derive and test relations between the Modified Mercalli Intensity (MMI) and the pseudo-acceleration response spectra at 1.0 and 0.3 s - SA(1.0 s) and SA(0.3 s) - in order to map response spectral ordinates for the 1906 San Francisco earthquake. Recent analyses of intensity have shown that MMI ??? 6 correlates both with peak ground velocity and with response spectra for periods from 0.5 to 3.0 s. We use these recent results to derive a linear relation between MMI and log SA(1.0 s), and we refine this relation by comparing the SA(1.0 s) estimated from Boatwright and Bundock's (2005) MMI map for the 1906 earthquake to the SA(1.0 s) calculated from recordings of the 1989 Loma Prieta earthquake. South of San Jose, the intensity distributions for the 1906 and 1989 earthquakes are remarkably similar, despite the difference in magnitude and rupture extent between the two events. We use recent strong motion regressions to derive a relation between SA(1.0 s) and SA(0.3 s) for a M7.8 strike-slip earthquake that depends on soil type, acceleration level, and source distance. We test this relation by comparing SA(0.3 s) estimated for the 1906 earthquake to SA(0.3 s) calculated from recordings of both the 1989 Loma Prieta and 1994 Northridge earthquakes, as functions of distance from the fault. ?? 2006, Earthquake Engineering Research Institute.

  19. Which Assessment Method of Malnutrition in Head and Neck Cancer?

    PubMed

    Saroul, Nicolas; Pastourel, Rémy; Mulliez, Aurélien; Farigon, Nicolas; Dupuch, Vincent; Mom, Thierry; Boirie, Yves; Gilain, Laurent

    2018-06-01

    Objective To assess the value of several diagnostic methods of nutritional status during the initial management of a head and neck cancer. Study Design Single-center prospective study. Setting Tertiary referral center. Subjects and Methods Ninety patients with head and neck cancer participated in the study. Assessment of their nutritional status was made with anthropometric, biological, body, and muscle measurements (the last by computed tomography: L3 muscle mass index [L3MMI]). Assessment of muscle performance (functional reflection of nutritional status) was made via the Short Physical Performance Battery test. The malnutrition thresholds were set according to the literature. Results Mean body mass index (BMI) was 24.6 ± 5.4 kg/m 2 . Mean weight loss and albumin levels were -4.5 ± 10.5 kg and 37.1 ± 5.2 g/L, respectively. Fourteen percent of patients were diagnosed as malnourished on the basis of BMI, 54% according to the Nutritional Risk Index (NRI), and 58% by L3MMI. There was 64% agreement between NRI and L3MMI ( P < .001). All patients identified as malnourished by BMI were considered as such by the other assessment methods; however, many malnourished patients had normal or high BMI. The Short Physical Performance Battery score was low particularly among patients considered to be the most undernourished by the other methods. Conclusion NRI and L3MMI are the best methods to identify patients as being malnourished. Functional muscle assessment can determine the severity of malnutrition.

  20. Chips: A Tool for Developing Software Interfaces Interactively.

    ERIC Educational Resources Information Center

    Cunningham, Robert E.; And Others

    This report provides a detailed description of Chips, an interactive tool for developing software employing graphical/computer interfaces on Xerox Lisp machines. It is noted that Chips, which is implemented as a collection of customizable classes, provides the programmer with a rich graphical interface for the creation of rich graphical…

  1. Emotion detection from text

    NASA Astrophysics Data System (ADS)

    Ramalingam, V. V.; Pandian, A.; Jaiswal, Abhijeet; Bhatia, Nikhar

    2018-04-01

    This paper presents a novel method based on concept of Machine Learning for Emotion Detection using various algorithms of Support Vector Machine and major emotions described are linked to the Word-Net for enhanced accuracy. The approach proposed plays a promising role to augment the Artificial Intelligence in the near future and could be vital in optimization of Human-Machine Interface.

  2. Formal verification of human-automation interaction

    NASA Technical Reports Server (NTRS)

    Degani, Asaf; Heymann, Michael

    2002-01-01

    This paper discusses a formal and rigorous approach to the analysis of operator interaction with machines. It addresses the acute problem of detecting design errors in human-machine interaction and focuses on verifying the correctness of the interaction in complex and automated control systems. The paper describes a systematic methodology for evaluating whether the interface provides the necessary information about the machine to enable the operator to perform a specified task successfully and unambiguously. It also addresses the adequacy of information provided to the user via training material (e.g., user manual) about the machine's behavior. The essentials of the methodology, which can be automated and applied to the verification of large systems, are illustrated by several examples and through a case study of pilot interaction with an autopilot aboard a modern commercial aircraft. The expected application of this methodology is an augmentation and enhancement, by formal verification, of human-automation interfaces.

  3. Quantitative analysis of the tectonic subsidence in the Potiguar Basin (NE Brazil)

    NASA Astrophysics Data System (ADS)

    Lopes, Juliana A. G.; de Castro, David L.; Bertotti, Giovanni

    2018-06-01

    The Potiguar Basin, located in the Brazilian Equatorial Margin, evolved from a complex rifting process implemented during the Atlantic Ocean opening in the Jurassic/Cretaceous. Different driving mechanisms were responsible for the onset of an aborted onshore rift and an offshore rift that initiated crustal rupture and the formation of a continental transform margin. Therefore, we applied the backstripping method to quantify the tectonic subsidence during the rift and post-rift phases of Potiguar Basin formation and to analyze the spatial variation of subsidence during the two successive and distinct tectonic events responsible for the basin evolution. The parameters required to apply this methodology were extracted from 2D seismic lines and exploratory well data. The tectonic subsidence curves present periods with moderate subsidence rates (up to 300 m/My), which correspond to the evolution of the onshore Potiguar Rift (∼141 to 128 Ma). From 128-118 Ma, the tectonic subsidence curves show no subsidence in the onshore Potiguar Basin, whereas subsidence occurred at high rates (over 300 m/My) in the offshore rift. The post-rift phase began ca. 118 Ma (Aptian), when the tectonic subsidence drastically slowed to less than 35 m/My, probably related to thermal relaxation. The tectonic subsidence rates in the various sectors of the Potiguar Rift, during the different rift phases, indicate that more intense faulting occurred in the southern portion of the onshore rift, along the main border faults, and in the southeastern portion of the offshore rift. During the post-rift phase, the tectonic subsidence rates increased from the onshore portion towards the offshore portion until the continental slope. The highest rates of post-rift subsidence (up to 35 m/My) are concentrated in the central region of the offshore portion and may be related to lithospheric processes related to the continental crust rupture and oceanic seafloor spreading. The variation in subsidence rates and the pattern of tectonic subsidence curves allowed us to interpret the tectonic signature recorded by the sedimentary sequences of the Potiguar Basin during its evolution. In the onshore rift area, the tectonic subsidence curves presented subsidence rates up to 300 m/My during a long-term rift phase (13 Ma), which confirmed that this portion had an extensional tectonic regime. In the offshore rift, the curves presented high subsidence rates of over 300 m/My in a shorter period (5-10 My), typical of basins formed in a transtensional tectonic regime.

  4. Matching brain-machine interface performance to space applications.

    PubMed

    Citi, Luca; Tonet, Oliver; Marinelli, Martina

    2009-01-01

    A brain-machine interface (BMI) is a particular class of human-machine interface (HMI). BMIs have so far been studied mostly as a communication means for people who have little or no voluntary control of muscle activity. For able-bodied users, such as astronauts, a BMI would only be practical if conceived as an augmenting interface. A method is presented for pointing out effective combinations of HMIs and applications of robotics and automation to space. Latency and throughput are selected as performance measures for a hybrid bionic system (HBS), that is, the combination of a user, a device, and a HMI. We classify and briefly describe HMIs and space applications and then compare the performance of classes of interfaces with the requirements of classes of applications, both in terms of latency and throughput. Regions of overlap correspond to effective combinations. Devices requiring simpler control, such as a rover, a robotic camera, or environmental controls are suitable to be driven by means of BMI technology. Free flyers and other devices with six degrees of freedom can be controlled, but only at low-interactivity levels. More demanding applications require conventional interfaces, although they could be controlled by BMIs once the same levels of performance as currently recorded in animal experiments are attained. Robotic arms and manipulators could be the next frontier for noninvasive BMIs. Integrating smart controllers in HBSs could improve interactivity and boost the use of BMI technology in space applications.

  5. A video, text, and speech-driven realistic 3-d virtual head for human-machine interface.

    PubMed

    Yu, Jun; Wang, Zeng-Fu

    2015-05-01

    A multiple inputs-driven realistic facial animation system based on 3-D virtual head for human-machine interface is proposed. The system can be driven independently by video, text, and speech, thus can interact with humans through diverse interfaces. The combination of parameterized model and muscular model is used to obtain a tradeoff between computational efficiency and high realism of 3-D facial animation. The online appearance model is used to track 3-D facial motion from video in the framework of particle filtering, and multiple measurements, i.e., pixel color value of input image and Gabor wavelet coefficient of illumination ratio image, are infused to reduce the influence of lighting and person dependence for the construction of online appearance model. The tri-phone model is used to reduce the computational consumption of visual co-articulation in speech synchronized viseme synthesis without sacrificing any performance. The objective and subjective experiments show that the system is suitable for human-machine interaction.

  6. Advanced warfighter machine interface (Invited Paper)

    NASA Astrophysics Data System (ADS)

    Franks, Erin

    2005-05-01

    Future military crewmen may have more individual and shared tasks to complete throughout a mission as a result of smaller crew sizes and an increased number of technology interactions. To maintain reasonable workload levels, the Warfighter Machine Interface (WMI) must provide information in a consistent, logical manner, tailored to the environment in which the soldier will be completing their mission. This paper addresses design criteria for creating an advanced, multi-modal warfighter machine interface for on-the-move mounted operations. The Vetronics Technology Integration (VTI) WMI currently provides capabilities such as mission planning and rehearsal, voice and data communications, and manned/unmanned vehicle payload and mobility control. A history of the crewstation and more importantly, the WMI software will be provided with an overview of requirements and criteria used for completing the design. Multiple phases of field and laboratory testing provide the opportunity to evaluate the design and hardware in stationary and motion environments. Lessons learned related to system usability and user performance are presented with mitigation strategies to be tested in the future.

  7. Open multi-agent control architecture to support virtual-reality-based man-machine interfaces

    NASA Astrophysics Data System (ADS)

    Freund, Eckhard; Rossmann, Juergen; Brasch, Marcel

    2001-10-01

    Projective Virtual Reality is a new and promising approach to intuitively operable man machine interfaces for the commanding and supervision of complex automation systems. The user interface part of Projective Virtual Reality heavily builds on latest Virtual Reality techniques, a task deduction component and automatic action planning capabilities. In order to realize man machine interfaces for complex applications, not only the Virtual Reality part has to be considered but also the capabilities of the underlying robot and automation controller are of great importance. This paper presents a control architecture that has proved to be an ideal basis for the realization of complex robotic and automation systems that are controlled by Virtual Reality based man machine interfaces. The architecture does not just provide a well suited framework for the real-time control of a multi robot system but also supports Virtual Reality metaphors and augmentations which facilitate the user's job to command and supervise a complex system. The developed control architecture has already been used for a number of applications. Its capability to integrate sensor information from sensors of different levels of abstraction in real-time helps to make the realized automation system very responsive to real world changes. In this paper, the architecture will be described comprehensively, its main building blocks will be discussed and one realization that is built based on an open source real-time operating system will be presented. The software design and the features of the architecture which make it generally applicable to the distributed control of automation agents in real world applications will be explained. Furthermore its application to the commanding and control of experiments in the Columbus space laboratory, the European contribution to the International Space Station (ISS), is only one example which will be described.

  8. Hand-in-hand advances in biomedical engineering and sensorimotor restoration.

    PubMed

    Pisotta, Iolanda; Perruchoud, David; Ionta, Silvio

    2015-05-15

    Living in a multisensory world entails the continuous sensory processing of environmental information in order to enact appropriate motor routines. The interaction between our body and our brain is the crucial factor for achieving such sensorimotor integration ability. Several clinical conditions dramatically affect the constant body-brain exchange, but the latest developments in biomedical engineering provide promising solutions for overcoming this communication breakdown. The ultimate technological developments succeeded in transforming neuronal electrical activity into computational input for robotic devices, giving birth to the era of the so-called brain-machine interfaces. Combining rehabilitation robotics and experimental neuroscience the rise of brain-machine interfaces into clinical protocols provided the technological solution for bypassing the neural disconnection and restore sensorimotor function. Based on these advances, the recovery of sensorimotor functionality is progressively becoming a concrete reality. However, despite the success of several recent techniques, some open issues still need to be addressed. Typical interventions for sensorimotor deficits include pharmaceutical treatments and manual/robotic assistance in passive movements. These procedures achieve symptoms relief but their applicability to more severe disconnection pathologies is limited (e.g. spinal cord injury or amputation). Here we review how state-of-the-art solutions in biomedical engineering are continuously increasing expectances in sensorimotor rehabilitation, as well as the current challenges especially with regards to the translation of the signals from brain-machine interfaces into sensory feedback and the incorporation of brain-machine interfaces into daily activities. Copyright © 2015 Elsevier B.V. All rights reserved.

  9. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Barrett, Brian; Brightwell, Ronald B.; Grant, Ryan

    This report presents a specification for the Portals 4 networ k programming interface. Portals 4 is intended to allow scalable, high-performance network communication betwee n nodes of a parallel computing system. Portals 4 is well suited to massively parallel processing and embedded syste ms. Portals 4 represents an adaption of the data movement layer developed for massively parallel processing platfor ms, such as the 4500-node Intel TeraFLOPS machine. Sandia's Cplant cluster project motivated the development of Version 3.0, which was later extended to Version 3.3 as part of the Cray Red Storm machine and XT line. Version 4 is tarmore » geted to the next generation of machines employing advanced network interface architectures that support enh anced offload capabilities.« less

  10. A facetless regrowth-free single mode laser based on MMI couplers

    NASA Astrophysics Data System (ADS)

    Caro, Ludovic; Kelly, Niall P.; Dernaika, Mohamad; Shayesteh, Maryam; Morrissey, Padraic E.; Alexander, Justin K.; Peters, Frank H.

    2017-09-01

    This paper presents a facetless, tunable laser operating near 1575 nm, as well as a theoretical model predicting spectral features of the laser. The lasers were fabricated without regrowth or advanced lithography techniques, and are based on MMI couplers and etched facets. Coarse vernier tuning was achieved over a range of 25 nm, while fine, thermal tuning was also demonstrated over a range of 1.5 nm. SMSR values of 25 dB and higher were observed, with a measured laser linewidth of 600 kHz.

  11. State of the art in nuclear telerobotics: focus on the man/machine connection

    NASA Astrophysics Data System (ADS)

    Greaves, Amna E.

    1995-12-01

    The interface between the human controller and remotely operated device is a crux of telerobotic investigation today. This human-to-machine connection is the means by which we communicate our commands to the device, as well as the medium for decision-critical feedback to the operator. The amount of information transferred through the user interface is growing. This can be seen as a direct result of our need to support added complexities, as well as a rapidly expanding domain of applications. A user interface, or UI, is therefore subject to increasing demands to present information in a meaningful manner to the user. Virtual reality, and multi degree-of-freedom input devices lend us the ability to augment the man/machine interface, and handle burgeoning amounts of data in a more intuitive and anthropomorphically correct manner. Along with the aid of 3-D input and output devices, there are several visual tools that can be employed as part of a graphical UI that enhance and accelerate our comprehension of the data being presented. Thus an advanced UI that features these improvements would reduce the amount of fatigue on the teleoperator, increase his level of safety, facilitate learning, augment his control, and potentially reduce task time. This paper investigates the cutting edge concepts and enhancements that lead to the next generation of telerobotic interface systems.

  12. DESIGN AND EVALUATION OF INDIVIDUAL ELEMENTS OF THE INTERFACE FOR AN AGRICULTURAL MACHINE.

    PubMed

    Rakhra, Aadesh K; Mann, Danny D

    2018-01-29

    If a user-centered approach is not used to design information displays, the quantity and quality of information presented to the user may not match the needs of the user, or it may exceed the capability of the human operator for processing and using that information. The result may be an excessive mental workload and reduced situation awareness of the operator, which can negatively affect the machine performance and operational outcomes. The increasing use of technology in agricultural machines may expose the human operator to excessive and undesirable information if the operator's information needs and information processing capabilities are ignored. In this study, a user-centered approach was used to design specific interface elements for an agricultural air seeder. Designs of the interface elements were evaluated in a laboratory environment by developing high-fidelity prototypes. Evaluations of the user interface elements yielded significant improvement in situation awareness (up to 11%; overall mean difference = 5.0 (4.8%), 95% CI (6.4728, 3.5939), p 0.0001). Mental workload was reduced by up to 19.7% (overall mean difference = -5.2 (-7.9%), n = 30, a = 0.05). Study participants rated the overall performance of the newly designed user-centered interface elements higher in comparison to the previous designs (overall mean difference = 27.3 (189.8%), 99% CI (35.150, 19.384), p 0.0001. Copyright© by the American Society of Agricultural Engineers.

  13. Automated placement of interfaces in conformational kinetics calculations using machine learning

    NASA Astrophysics Data System (ADS)

    Grazioli, Gianmarc; Butts, Carter T.; Andricioaei, Ioan

    2017-10-01

    Several recent implementations of algorithms for sampling reaction pathways employ a strategy for placing interfaces or milestones across the reaction coordinate manifold. Interfaces can be introduced such that the full feature space describing the dynamics of a macromolecule is divided into Voronoi (or other) cells, and the global kinetics of the molecular motions can be calculated from the set of fluxes through the interfaces between the cells. Although some methods of this type are exact for an arbitrary set of cells, in practice, the calculations will converge fastest when the interfaces are placed in regions where they can best capture transitions between configurations corresponding to local minima. The aim of this paper is to introduce a fully automated machine-learning algorithm for defining a set of cells for use in kinetic sampling methodologies based on subdividing the dynamical feature space; the algorithm requires no intuition about the system or input from the user and scales to high-dimensional systems.

  14. Automated placement of interfaces in conformational kinetics calculations using machine learning.

    PubMed

    Grazioli, Gianmarc; Butts, Carter T; Andricioaei, Ioan

    2017-10-21

    Several recent implementations of algorithms for sampling reaction pathways employ a strategy for placing interfaces or milestones across the reaction coordinate manifold. Interfaces can be introduced such that the full feature space describing the dynamics of a macromolecule is divided into Voronoi (or other) cells, and the global kinetics of the molecular motions can be calculated from the set of fluxes through the interfaces between the cells. Although some methods of this type are exact for an arbitrary set of cells, in practice, the calculations will converge fastest when the interfaces are placed in regions where they can best capture transitions between configurations corresponding to local minima. The aim of this paper is to introduce a fully automated machine-learning algorithm for defining a set of cells for use in kinetic sampling methodologies based on subdividing the dynamical feature space; the algorithm requires no intuition about the system or input from the user and scales to high-dimensional systems.

  15. Stability Assessment of a System Comprising a Single Machine and Inverter with Scalable Ratings

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Johnson, Brian B; Lin, Yashen; Gevorgian, Vahan

    From the inception of power systems, synchronous machines have acted as the foundation of large-scale electrical infrastructures and their physical properties have formed the cornerstone of system operations. However, power electronics interfaces are playing a growing role as they are the primary interface for several types of renewable energy sources and storage technologies. As the role of power electronics in systems continues to grow, it is crucial to investigate the properties of bulk power systems in low inertia settings. In this paper, we assess the properties of coupled machine-inverter systems by studying an elementary system comprised of a synchronous generator,more » three-phase inverter, and a load. Furthermore, the inverter model is formulated such that its power rating can be scaled continuously across power levels while preserving its closed-loop response. Accordingly, the properties of the machine-inverter system can be assessed for varying ratios of machine-to-inverter power ratings and, hence, differing levels of inertia. After linearizing the model and assessing its eigenvalues, we show that system stability is highly dependent on the interaction between the inverter current controller and machine exciter, thus uncovering a key concern with mixed machine-inverter systems and motivating the need for next-generation grid-stabilizing inverter controls.« less

  16. Semantics of User Interface for Image Retrieval: Possibility Theory and Learning Techniques.

    ERIC Educational Resources Information Center

    Crehange, M.; And Others

    1989-01-01

    Discusses the need for a rich semantics for the user interface in interactive image retrieval and presents two methods for building such interfaces: possibility theory applied to fuzzy data retrieval, and a machine learning technique applied to learning the user's deep need. Prototypes developed using videodisks and knowledge-based software are…

  17. Engaging a community towards marine cyberinfrastructure: Lessons Learned from The Marine Metadata Interoperability initiative

    NASA Astrophysics Data System (ADS)

    Galbraith, N. R.; Graybeal, J.; Bermudez, L. E.; Wright, D.

    2005-12-01

    The Marine Metadata Interoperability (MMI) initiative promotes the exchange, integration and use of marine data through enhanced data publishing, discovery, documentation and accessibility. The project, operating since late 2004, presents several cultural organizational challenges because of the diversity of participants: scientists, technical experts, and data managers from around the world, all working in organizations with different corporate cultures, funding structures, and systems of decision-making. MMI provides educational resources at several levels. For instance, short introductions to metadata concepts are available, as well as guides and "cookbooks" for the quick and efficient preparation of marine metadata. For those who are building major marine data systems, including ocean-observing capabilities, there are training materials, marine metadata content examples, and resources for mapping elements between different metadata standards. The MMI also provides examples of good metadata practices in existing data systems, including the EU's Marine XML project, and functioning ocean/coastal clearinghouses and atlases developed by MMI team members. Communication tools that help build community: 1) Website, used to introduce the initiative to new visitors, and to provide in-depth guidance and resources to members and visitors. The site is built using Plone, an open source web content management system. Plone allows the site to serve as a wiki, to which every user can contribute material. This keeps the membership engaged and spreads the responsibility for the tasks of updating and expanding the site. 2) Email-lists, to engage the broad ocean sciences community. The discussion forums "news," "ask," and "site-help" are available for receiving regular updates on MMI activities, seeking advice or support on projects and standards, or for assistance with using the MMI site. Internal email lists are provided for the Technical Team, the Steering Committee and Executive Committee, and for several content-centered teams. These lists help keep committee members connected, and have been very successful in building consensus and momentum. 3) Regularly scheduled telecons, to provide the chance for interaction between members without the need to physically attend meetings. Both the steering committee and the technical team convene via phone every month. Discussions are guided by agendas published in advance, and minutes are kept on-line for reference. These telecons have been an important tool in moving the MMI project forward; they give members an opportunity for informal discussion and provide a timeframe for accomplishing tasks. 4) Workshops, to make progress towards community agreement, such as the technical workshop "Advancing Domain Vocabularies" August 9-11, 2005, in Boulder, Colorado, where featured domain and metadata experts developed mappings between existing marine metadata vocabularies. Most of the work of the meeting was performed in six small, carefully organized breakout teams, oriented around specific domains. 5) Calendar of events, to keep update the users and where any event related to marine metadata and interoperability can be posted. 6) Specific tools to reach agreements among distributed communities. For example, we developed a tool called Vocabulary Integration Environment (VINE), that allows formalized agreements of mappings across different vocabularies.

  18. A Formal Characterization of Relevant Information in Multi-Agent Systems

    DTIC Science & Technology

    2009-10-01

    Conference iTrust. (2004) [17] Sadek, D.: Le dialogue homme-machine : de l’ ergonomie des interfaces à l’ agent intelligent dia- loguant. In: Nouvelles interfaces hommemachine, Lavoisier Editeur, Arago 18 (1996) 277–321

  19. Charting the energy landscape of metal/organic interfaces via machine learning

    NASA Astrophysics Data System (ADS)

    Scherbela, Michael; Hörmann, Lukas; Jeindl, Andreas; Obersteiner, Veronika; Hofmann, Oliver T.

    2018-04-01

    The rich polymorphism exhibited by inorganic/organic interfaces is a major challenge for materials design. In this work, we present a method to efficiently explore the potential energy surface and predict the formation energies of polymorphs and defects. This is achieved by training a machine learning model on a list of only 100 candidate structures that are evaluated via dispersion-corrected density functional theory (DFT) calculations. We demonstrate the power of this approach for tetracyanoethylene on Ag(100) and explain the anisotropic ordering that is observed experimentally.

  20. Charting the energy landscape of metal/organic interfaces via machine learning

    DOE PAGES

    Scherbela, Michael; Hormann, Lukas; Jeindl, Andreas; ...

    2018-04-17

    The rich polymorphism exhibited by inorganic/organic interfaces is a major challenge for materials design. Here in this work, we present a method to efficiently explore the potential energy surface and predict the formation energies of polymorphs and defects. This is achieved by training a machine learning model on a list of only 100 candidate structures that are evaluated via dispersion-corrected density functional theory (DFT) calculations. Finally, we demonstrate the power of this approach for tetracyanoethylene on Ag(100) and explain the anisotropic ordering that is observed experimentally.

  1. Charting the energy landscape of metal/organic interfaces via machine learning

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Scherbela, Michael; Hormann, Lukas; Jeindl, Andreas

    The rich polymorphism exhibited by inorganic/organic interfaces is a major challenge for materials design. Here in this work, we present a method to efficiently explore the potential energy surface and predict the formation energies of polymorphs and defects. This is achieved by training a machine learning model on a list of only 100 candidate structures that are evaluated via dispersion-corrected density functional theory (DFT) calculations. Finally, we demonstrate the power of this approach for tetracyanoethylene on Ag(100) and explain the anisotropic ordering that is observed experimentally.

  2. Adaptive displays and controllers using alternative feedback.

    PubMed

    Repperger, D W

    2004-12-01

    Investigations on the design of haptic (force reflecting joystick or force display) controllers were conducted by viewing the display of force information within the context of several different paradigms. First, using analogies from electrical and mechanical systems, certain schemes of the haptic interface were hypothesized which may improve the human-machine interaction with respect to various criteria. A discussion is given on how this interaction benefits the electrical and mechanical system. To generalize this concept to the design of human-machine interfaces, three studies with haptic mechanisms were then synthesized and analyzed.

  3. Developing Human-Machine Interfaces to Support Appropriate Trust and Reliance on Automated Combat Identification Systems (Developpement d’Interfaces Homme-Machine Pour Appuyer la Confiance dans les Systemes Automatises d’Identification au Combat)

    DTIC Science & Technology

    2008-03-31

    on automation; the ‘response bias’ approach. This new approach is based on Signal Detection Theory (SDT) (Macmillan & Creelman , 1991; Wickens...SDT), response bias will vary with the expectation of the target probability, whereas their sensitivity will stay constant (Macmillan & Creelman ...measures, C has the simplest statistical properties (Macmillan & Creelman , 1991, p273), and it was also the measure used in Dzindolet et al.’s study

  4. Man-machine interfaces in health care

    NASA Technical Reports Server (NTRS)

    Charles, Steve; Williams, Roy E.

    1991-01-01

    The surgeon, like the pilot, is confronted with an ever increasing volume of voice, data, and image input. Simultaneously, the surgeon must control a rapidly growing number of devices to deliver care to the patient. The broad disciplines of man-machine interface design, systems integration, and teleoperation will play a role in the operating room of the future. The purpose of this communication is to report the incorporation of these design concepts into new surgical and laser delivery systems. A review of each general problem area and the systems under development to solve the problems are presented.

  5. Cutting Modeling of Hybrid CFRP/Ti Composite with Induced Damage Analysis

    PubMed Central

    Xu, Jinyang; El Mansori, Mohamed

    2016-01-01

    In hybrid carbon fiber reinforced polymer (CFRP)/Ti machining, the bi-material interface is the weakest region vulnerable to severe damage formation when the tool cutting from one phase to another phase and vice versa. The interface delamination as well as the composite-phase damage is the most serious failure dominating the bi-material machining. In this paper, an original finite element (FE) model was developed to inspect the key mechanisms governing the induced damage formation when cutting this multi-phase material. The hybrid composite model was constructed by establishing three disparate physical constituents, i.e., the Ti phase, the interface, and the CFRP phase. Different constitutive laws and damage criteria were implemented to build up the entire cutting behavior of the bi-material system. The developed orthogonal cutting (OC) model aims to characterize the dynamic mechanisms of interface delamination formation and the affected interface zone (AIZ). Special focus was made on the quantitative analyses of the parametric effects on the interface delamination and composite-phase damage. The numerical results highlighted the pivotal role of AIZ in affecting the formation of interface delamination, and the significant impacts of feed rate and cutting speed on delamination extent and fiber/matrix failure. PMID:28787824

  6. Transient Hypothyroidism During Lactation Arrests Myelination in the Anterior Commissure of Rats. A Magnetic Resonance Image and Electron Microscope Study.

    PubMed

    Lucia, Federico S; Pacheco-Torres, Jesús; González-Granero, Susana; Canals, Santiago; Obregón, María-Jesús; García-Verdugo, José M; Berbel, Pere

    2018-01-01

    Thyroid hormone deficiency at early postnatal ages affects the cytoarchitecture and function of neocortical and telencephalic limbic areas, leading to impaired associative memory and in a wide spectrum of neurological and mental diseases. Neocortical areas project interhemispheric axons mostly through the corpus callosum and to a lesser extent through the anterior commissure (AC), while limbic areas mostly project through the AC and hippocampal commissures. Functional magnetic resonance data from children with late diagnosed congenital hypothyroidism and abnormal verbal memory processing, suggest altered ipsilateral and contralateral telencephalic connections. Gestational hypothyroidism affects AC development but the possible effect of transient and chronic postnatal hypothyroidism, as occurs in late diagnosed neonates with congenital hypothyroidism and in children growing up in iodine deficient areas, still remains unknown. We studied AC development using in vivo magnetic resonance imaging and electron microscopy in hypothyroid and control male rats. Four groups of methimazole (MMI) treated rats were studied. One group was MMI-treated from postnatal day (P) 0 to P21; some of these rats were also treated with L-thyroxine (T4) from P15 to P21, as a model for early transient hypothyroidism. Other rats were MMI-treated from P0 to P150 and from embryonic day (E) 10 to P170, as a chronic hypothyroidism group. The results were compared with age paired control rats. The normalized T2 signal using magnetic resonance image was higher in MMI-treated rats and correlated with the number and percentage of myelinated axons. Using electron microscopy, we observed decreased myelinated axon number and density in transient and chronic hypothyroid rats at P150, unmyelinated axon number increased slightly in chronic hypothyroid rats. In MMI-treated rats, the myelinated axon g-ratio and conduction velocity was similar to control rats, but with a decrease in conduction delays. These data show that early postnatal transient and chronic hypothyroidism alters AC maturation that may affect the transfer of information through the AC. The alterations cannot be recovered after delayed T4-treatment. Our data support the neurocognitive delay found in late T4-treated children with congenital hypothyroidism.

  7. VOTable JAVA Streaming Writer and Applications.

    NASA Astrophysics Data System (ADS)

    Kulkarni, P.; Kembhavi, A.; Kale, S.

    2004-07-01

    Virtual Observatory related tools use a new standard for data transfer called the VOTable format. This is a variant of the xml format that enables easy transfer of data over the web. We describe a streaming interface that can bridge the VOTable format, through a user friendly graphical interface, with the FITS and ASCII formats, which are commonly used by astronomers. A streaming interface is important for efficient use of memory because of the large size of catalogues. The tools are developed in JAVA to provide a platform independent interface. We have also developed a stand-alone version that can be used to convert data stored in ASCII or FITS format on a local machine. The Streaming writer is successfully being used in VOPlot (See Kale et al 2004 for a description of VOPlot).We present the test results of converting huge FITS and ASCII data into the VOTable format on machines that have only limited memory.

  8. What Do We Really Need? Visions of an Ideal Human-Machine Interface for NOTES Mechatronic Support Systems From the View of Surgeons, Gastroenterologists, and Medical Engineers.

    PubMed

    Kranzfelder, Michael; Schneider, Armin; Fiolka, Adam; Koller, Sebastian; Wilhelm, Dirk; Reiser, Silvano; Meining, Alexander; Feussner, Hubertus

    2015-08-01

    To investigate why natural orifice translumenal endoscopic surgery (NOTES) has not yet become widely accepted and to prove whether the main reason is still the lack of appropriate platforms due to the deficiency of applicable interfaces. To assess expectations of a suitable interface design, we performed a survey on human-machine interfaces for NOTES mechatronic support systems among surgeons, gastroenterologists, and medical engineers. Of 120 distributed questionnaires, each consisting of 14 distinct questions, 100 (83%) were eligible for analysis. A mechatronic platform for NOTES was considered "important" by 71% of surgeons, 83% of gastroenterologist,s and 56% of medical engineers. "Intuitivity" and "simple to use" were the most favored aspects (33% to 51%). Haptic feedback was considered "important" by 70% of participants. In all, 53% of surgeons, 50% of gastroenterologists, and 33% of medical engineers already had experience with NOTES platforms or other surgical robots; however, current interfaces only met expectations in just more than 50%. Whereas surgeons did not favor a certain working posture, gastroenterologists and medical engineers preferred a sitting position. Three-dimensional visualization was generally considered "nice to have" (67% to 72%); however, for 26% of surgeons, 17% of gastroenterologists, and 7% of medical engineers it did not matter (P = 0.018). Requests and expectations of human-machine interfaces for NOTES seem to be generally similar for surgeons, gastroenterologist, and medical engineers. Consensus exists on the importance of developing interfaces that should be both intuitive and simple to use, are similar to preexisting familiar instruments, and exceed current available systems. © The Author(s) 2014.

  9. AZOrange - High performance open source machine learning for QSAR modeling in a graphical programming environment

    PubMed Central

    2011-01-01

    Background Machine learning has a vast range of applications. In particular, advanced machine learning methods are routinely and increasingly used in quantitative structure activity relationship (QSAR) modeling. QSAR data sets often encompass tens of thousands of compounds and the size of proprietary, as well as public data sets, is rapidly growing. Hence, there is a demand for computationally efficient machine learning algorithms, easily available to researchers without extensive machine learning knowledge. In granting the scientific principles of transparency and reproducibility, Open Source solutions are increasingly acknowledged by regulatory authorities. Thus, an Open Source state-of-the-art high performance machine learning platform, interfacing multiple, customized machine learning algorithms for both graphical programming and scripting, to be used for large scale development of QSAR models of regulatory quality, is of great value to the QSAR community. Results This paper describes the implementation of the Open Source machine learning package AZOrange. AZOrange is specially developed to support batch generation of QSAR models in providing the full work flow of QSAR modeling, from descriptor calculation to automated model building, validation and selection. The automated work flow relies upon the customization of the machine learning algorithms and a generalized, automated model hyper-parameter selection process. Several high performance machine learning algorithms are interfaced for efficient data set specific selection of the statistical method, promoting model accuracy. Using the high performance machine learning algorithms of AZOrange does not require programming knowledge as flexible applications can be created, not only at a scripting level, but also in a graphical programming environment. Conclusions AZOrange is a step towards meeting the needs for an Open Source high performance machine learning platform, supporting the efficient development of highly accurate QSAR models fulfilling regulatory requirements. PMID:21798025

  10. AZOrange - High performance open source machine learning for QSAR modeling in a graphical programming environment.

    PubMed

    Stålring, Jonna C; Carlsson, Lars A; Almeida, Pedro; Boyer, Scott

    2011-07-28

    Machine learning has a vast range of applications. In particular, advanced machine learning methods are routinely and increasingly used in quantitative structure activity relationship (QSAR) modeling. QSAR data sets often encompass tens of thousands of compounds and the size of proprietary, as well as public data sets, is rapidly growing. Hence, there is a demand for computationally efficient machine learning algorithms, easily available to researchers without extensive machine learning knowledge. In granting the scientific principles of transparency and reproducibility, Open Source solutions are increasingly acknowledged by regulatory authorities. Thus, an Open Source state-of-the-art high performance machine learning platform, interfacing multiple, customized machine learning algorithms for both graphical programming and scripting, to be used for large scale development of QSAR models of regulatory quality, is of great value to the QSAR community. This paper describes the implementation of the Open Source machine learning package AZOrange. AZOrange is specially developed to support batch generation of QSAR models in providing the full work flow of QSAR modeling, from descriptor calculation to automated model building, validation and selection. The automated work flow relies upon the customization of the machine learning algorithms and a generalized, automated model hyper-parameter selection process. Several high performance machine learning algorithms are interfaced for efficient data set specific selection of the statistical method, promoting model accuracy. Using the high performance machine learning algorithms of AZOrange does not require programming knowledge as flexible applications can be created, not only at a scripting level, but also in a graphical programming environment. AZOrange is a step towards meeting the needs for an Open Source high performance machine learning platform, supporting the efficient development of highly accurate QSAR models fulfilling regulatory requirements.

  11. Arbitrary-ratio power splitter based on nonlinear multimode interference coupler

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Tajaldini, Mehdi; Young Researchers and Elite Club, Baft Branch, Islamic Azad University, Baft; Jafri, Mohd Zubir Mat

    2015-04-24

    We propose an ultra-compact multimode interference (MMI) power splitter based on nonlinear effects from simulations using nonlinear modal propagation analysis (NMPA) cooperation with finite difference Method (FDM) to access free choice of splitting ratio. Conventional multimode interference power splitter could only obtain a few discrete ratios. The power splitting ratio may be adjusted continuously while the input set power is varying by a tunable laser. In fact, using an ultra- compact MMI with a simple structure that is launched by a tunable nonlinear input fulfills the problem of arbitrary-ratio in integrated photonics circuits. Silicon on insulator (SOI) is used asmore » the offered material due to the high contrast refractive index and Centro symmetric properties. The high-resolution images at the end of the multimode waveguide in the simulated power splitter have a high power balance, whereas access to a free choice of splitting ratio is not possible under the linear regime in the proposed length range except changes in the dimension for any ratio. The compact dimensions and ideal performance of the device are established according to optimized parameters. The proposed regime can be extended to the design of M×N arbitrary power splitters ratio for programmable logic devices in all optical digital signal processing. The results of this study indicate that nonlinear modal propagation analysis solves the miniaturization problem for all-optical devices based on MMI couplers to achieve multiple functions in a compact planar integrated circuit and also overcomes the limitations of previously proposed methods for nonlinear MMI.« less

  12. Differences in Femoral Head Penetration Between Highly Cross-Linked Polyethylene Cemented Sockets and Uncemented Liners.

    PubMed

    Morita, Daigo; Seki, Taisuke; Higuchi, Yoshitoshi; Takegami, Yasuhiko; Ishiguro, Naoki

    2017-12-01

    This study aimed at investigating differences in femoral head penetration between highly cross-linked polyethylene (HXLPE) cemented sockets and uncemented liners during 5 years postoperatively. Ninety-six patients (106 hips) with a mean age of 64.4 (range, 35-83) years underwent total hip arthroplasty using a HXLPE cemented socket or liner and were respectively divided into cemented (35 patients [37 hips]) and uncemented (61 patients [69 hips]) groups. Femoral head penetrations were evaluated on both anteroposterior (AP)-view and Lauenstein-view radiographs, and mean polyethylene (PE) wear rates were calculated based on femoral head penetration from 2 to 5 years. Multivariate analyses were performed to assess risk factors for PE wear. At 5 years postoperatively, the cemented and uncemented groups exhibited proximal direction femoral head penetrations of 0.103 mm and 0.124 mm (P = .226) and anterior direction penetrations of 0.090 mm and 0.151 mm (P = .002), respectively. The corresponding mean PE wear rates were 0.004 mm/y and 0.009 mm/y in the AP-view (P = .286) and 0.005 mm/y and 0.012 mm/y in the Lauenstein-view (P = .168), respectively. Left-side operation and high activity were independent risk factors for PE wear on AP-view. When HXLPE was used, all mean PE wear rates were very low and those of cemented sockets and uncemented liners were very similar. PE particle theory suggests that the occurrence of osteolysis and related aseptic loosening might consequently decrease. Copyright © 2017 Elsevier Inc. All rights reserved.

  13. Bilateral medial medullary infarction: a systematic review.

    PubMed

    Pongmoragot, Jitphapa; Parthasarathy, Sujatha; Selchen, Daniel; Saposnik, Gustavo

    2013-08-01

    Bilateral infarction of the medial medulla (MMI) is rare. Limited information is available on clinical characteristics, etiology, and prognosis. High-resolution neuroimaging has a major role in elucidating the underlying stroke mechanism. The aim of this systematic review was to analyze the clinical presentations, stroke mechanisms, and outcomes in patients with bilateral MMI. We performed a systematic review of the literature from 1992-2011 that reported on clinical presentations, stroke mechanism, and/or outcomes in patients with magnetic resonance imaging-proven bilateral MMI. Medline, EMBASE, and Web of Science Scholars Portal were searched without language restriction. Two reviewers independently assessed identified studies to determine eligibility, validity, and quality. The primary outcome was inpatient mortality; a secondary outcome was case fatality at 12 months. We identified 138 articles from Medline, EMBASE, and Scholars Portal including the MeSH terms "brainstem infarction," "medulla," and "bilateral." Twenty-nine articles met our inclusion criteria, including a total of 38 cases with bilateral MMI, and included in our study. These 38 patients had a mean age of 62.2 years and were predominately male (74.2%). The most common clinical presentations were motor weakness in 78.4%, dysarthria in 48.6%, and hypoglossal palsy in 40.5%. The most common vascular pathology was vertebral artery atherosclerosis, in 38.5%. The clinical outcome was poor (mortality, 23.8%; dependency, 61.9%). Bilateral medial medullary infarction is a rare stroke syndrome. Clinical presentations were mostly rostral medullary lesions. Large-artery atherosclerosis and branch disease were the most common stroke mechanisms. The clinical outcome was usually poor. Copyright © 2013 National Stroke Association. Published by Elsevier Inc. All rights reserved.

  14. Thermocouple and infrared sensor-based measurement of temperature distribution in metal cutting.

    PubMed

    Kus, Abdil; Isik, Yahya; Cakir, M Cemal; Coşkun, Salih; Özdemir, Kadir

    2015-01-12

    In metal cutting, the magnitude of the temperature at the tool-chip interface is a function of the cutting parameters. This temperature directly affects production; therefore, increased research on the role of cutting temperatures can lead to improved machining operations. In this study, tool temperature was estimated by simultaneous temperature measurement employing both a K-type thermocouple and an infrared radiation (IR) pyrometer to measure the tool-chip interface temperature. Due to the complexity of the machining processes, the integration of different measuring techniques was necessary in order to obtain consistent temperature data. The thermal analysis results were compared via the ANSYS finite element method. Experiments were carried out in dry machining using workpiece material of AISI 4140 alloy steel that was heat treated by an induction process to a hardness of 50 HRC. A PVD TiAlN-TiN-coated WNVG 080404-IC907 carbide insert was used during the turning process. The results showed that with increasing cutting speed, feed rate and depth of cut, the tool temperature increased; the cutting speed was found to be the most effective parameter in assessing the temperature rise. The heat distribution of the cutting tool, tool-chip interface and workpiece provided effective and useful data for the optimization of selected cutting parameters during orthogonal machining.

  15. Thermocouple and Infrared Sensor-Based Measurement of Temperature Distribution in Metal Cutting

    PubMed Central

    Kus, Abdil; Isik, Yahya; Cakir, M. Cemal; Coşkun, Salih; Özdemir, Kadir

    2015-01-01

    In metal cutting, the magnitude of the temperature at the tool-chip interface is a function of the cutting parameters. This temperature directly affects production; therefore, increased research on the role of cutting temperatures can lead to improved machining operations. In this study, tool temperature was estimated by simultaneous temperature measurement employing both a K-type thermocouple and an infrared radiation (IR) pyrometer to measure the tool-chip interface temperature. Due to the complexity of the machining processes, the integration of different measuring techniques was necessary in order to obtain consistent temperature data. The thermal analysis results were compared via the ANSYS finite element method. Experiments were carried out in dry machining using workpiece material of AISI 4140 alloy steel that was heat treated by an induction process to a hardness of 50 HRC. A PVD TiAlN-TiN-coated WNVG 080404-IC907 carbide insert was used during the turning process. The results showed that with increasing cutting speed, feed rate and depth of cut, the tool temperature increased; the cutting speed was found to be the most effective parameter in assessing the temperature rise. The heat distribution of the cutting tool, tool-chip interface and workpiece provided effective and useful data for the optimization of selected cutting parameters during orthogonal machining. PMID:25587976

  16. Integration of an intelligent systems behavior simulator and a scalable soldier-machine interface

    NASA Astrophysics Data System (ADS)

    Johnson, Tony; Manteuffel, Chris; Brewster, Benjamin; Tierney, Terry

    2007-04-01

    As the Army's Future Combat Systems (FCS) introduce emerging technologies and new force structures to the battlefield, soldiers will increasingly face new challenges in workload management. The next generation warfighter will be responsible for effectively managing robotic assets in addition to performing other missions. Studies of future battlefield operational scenarios involving the use of automation, including the specification of existing and proposed technologies, will provide significant insight into potential problem areas regarding soldier workload. The US Army Tank Automotive Research, Development, and Engineering Center (TARDEC) is currently executing an Army technology objective program to analyze and evaluate the effect of automated technologies and their associated control devices with respect to soldier workload. The Human-Robotic Interface (HRI) Intelligent Systems Behavior Simulator (ISBS) is a human performance measurement simulation system that allows modelers to develop constructive simulations of military scenarios with various deployments of interface technologies in order to evaluate operator effectiveness. One such interface is TARDEC's Scalable Soldier-Machine Interface (SMI). The scalable SMI provides a configurable machine interface application that is capable of adapting to several hardware platforms by recognizing the physical space limitations of the display device. This paper describes the integration of the ISBS and Scalable SMI applications, which will ultimately benefit both systems. The ISBS will be able to use the Scalable SMI to visualize the behaviors of virtual soldiers performing HRI tasks, such as route planning, and the scalable SMI will benefit from stimuli provided by the ISBS simulation environment. The paper describes the background of each system and details of the system integration approach.

  17. SOI ring resonators with controllable MMI coupler sections

    NASA Astrophysics Data System (ADS)

    Hu, Youfang; Gardes, Frédéric Y.; Mashanovich, Goran Z.; Reed, Graham T.

    2011-01-01

    A ring resonator using a single 2×2 MMI as the coupler section has the distinct advantages of low sensitivity to fabrication error, temperature, wavelength and polarisation. However, the coupling coefficient of the 2×2 MMI coupler is fixed; hence, the performance of this type of device is limited, e.g. transmission spectrum with high extinction ratio is difficult to achieve. We have designed and simulated ring resonators with coupler sections consisting of two 2×2 MMIs and phase shifters, so that the coupling efficiency can be varied from 0% to 100% with relative ease. For a single ring resonator, the transmission spectrum can be controlled to achieve an extinction ratio of >20dB and a spectral bandwidth of <1nm. For a multiple ring filter, the transmission spectrum can be controlled to achieve an extinction ratio of >30dB and a bandwidth of <1nm in addition, a flat-top transmission spectrum is also achievable. The whole device has a footprint of approximately 200μm by 100μm.

  18. Practical image registration concerns overcome by the weighted and filtered mutual information metric

    NASA Astrophysics Data System (ADS)

    Keane, Tommy P.; Saber, Eli; Rhody, Harvey; Savakis, Andreas; Raj, Jeffrey

    2012-04-01

    Contemporary research in automated panorama creation utilizes camera calibration or extensive knowledge of camera locations and relations to each other to achieve successful results. Research in image registration attempts to restrict these same camera parameters or apply complex point-matching schemes to overcome the complications found in real-world scenarios. This paper presents a novel automated panorama creation algorithm by developing an affine transformation search based on maximized mutual information (MMI) for region-based registration. Standard MMI techniques have been limited to applications with airborne/satellite imagery or medical images. We show that a novel MMI algorithm can approximate an accurate registration between views of realistic scenes of varying depth distortion. The proposed algorithm has been developed using stationary, color, surveillance video data for a scenario with no a priori camera-to-camera parameters. This algorithm is robust for strict- and nearly-affine-related scenes, while providing a useful approximation for the overlap regions in scenes related by a projective homography or a more complex transformation, allowing for a set of efficient and accurate initial conditions for pixel-based registration.

  19. Tunable multiwavelength Tm-doped fiber laser based on the multimode interference effect.

    PubMed

    Zhang, Peng; Wang, Tianshu; Ma, Wanzhuo; Dong, Keyan; Jiang, Huilin

    2015-05-20

    A simple multiwavelength Tm-doped fiber laser at the 2 μm band based on multimode interference (MMI) is proposed and experimentally demonstrated. In this scheme, a 4 m Tm-doped single-mode fiber is pumped by a 1568 nm laser, and a single-mode-multimode-single-mode (SMS) fiber structure is used as an MMI filter in which the multimode fiber is used to tune the laser. Laser operation of up to three wavelengths is obtained based on the MMI filter. The wavelengths can be tuned by adjusting the polarization controller and rotating the multimode fiber in the SMS structure, and the tuning region is about 24 nm, i.e., 1892-1916 nm. The side-mode suppression ratio of the laser is about 54 dB. The 3 dB linewidth is less than 0.04 nm. Peak fluctuation at each wavelength is analyzed, and the results show that the power fluctuation is less than 3 dB around the average power.

  20. Multiprocessor Z-Buffer Architecture for High-Speed, High Complexity Computer Image Generation.

    DTIC Science & Technology

    1983-12-01

    Oversampling 50 17. "Poking Through" Effects 51 18. Sampling Paths 52 19. Triangle Variables 54 20. Intelligent Tiling Algorithm 61 21. Tiler Functional Blocks...64 * 22. HSD Interface 65 23. Tiling Machine Setup 67 24. Tiling Machine 68 25. Tile Accumulate 69 26. A lx$ Sorting Machine 77 27. A 2x8 Sorting...Delay 227 87. Effect of Triangle Size on Tiler Throughput Rates 229 88. Tiling Machine Setup Stage Performance for Oversample Mode 234 89. Tiling

  1. Intelligible machine learning with malibu.

    PubMed

    Langlois, Robert E; Lu, Hui

    2008-01-01

    malibu is an open-source machine learning work-bench developed in C/C++ for high-performance real-world applications, namely bioinformatics and medical informatics. It leverages third-party machine learning implementations for more robust bug-free software. This workbench handles several well-studied supervised machine learning problems including classification, regression, importance-weighted classification and multiple-instance learning. The malibu interface was designed to create reproducible experiments ideally run in a remote and/or command line environment. The software can be found at: http://proteomics.bioengr. uic.edu/malibu/index.html.

  2. A study of speech interfaces for the vehicle environment.

    DOT National Transportation Integrated Search

    2013-05-01

    Over the past few years, there has been a shift in automotive human machine interfaces from : visual-manual interactions (pushing buttons and rotating knobs) to speech interaction. In terms of : distraction, the industry views speech interaction as a...

  3. Man-machine interface issues in space telerobotics: A JPL research and development program

    NASA Technical Reports Server (NTRS)

    Bejczy, A. K.

    1987-01-01

    Technology issues related to the use of robots as man-extension or telerobot systems in space are discussed and exemplified. General considerations are presentd on control and information problems in space teleoperation and on the characteristics of Earth orbital teleoperation. The JPL R and D work in the area of man-machine interface devices and techniques for sensing and computer-based control is briefly summarized. The thrust of this R and D effort is to render space teleoperation efficient and safe through the use of devices and techniques which will permit integrated and task-level (intelligent) two-way control communication between human operator and telerobot machine in Earth orbit. Specific control and information display devices and techniques are discussed and exemplified with development results obtained at JPL in recent years.

  4. Method and system for providing work machine multi-functional user interface

    DOEpatents

    Hoff, Brian D [Peoria, IL; Akasam, Sivaprasad [Peoria, IL; Baker, Thomas M [Peoria, IL

    2007-07-10

    A method is performed to provide a multi-functional user interface on a work machine for displaying suggested corrective action. The process includes receiving status information associated with the work machine and analyzing the status information to determine an abnormal condition. The process also includes displaying a warning message on the display device indicating the abnormal condition and determining one or more corrective actions to handle the abnormal condition. Further, the process includes determining an appropriate corrective action among the one or more corrective actions and displaying a recommendation message on the display device reflecting the appropriate corrective action. The process may also include displaying a list including the remaining one or more corrective actions on the display device to provide alternative actions to an operator.

  5. Ultrasensitive and Highly Stable Resistive Pressure Sensors with Biomaterial-Incorporated Interfacial Layers for Wearable Health-Monitoring and Human-Machine Interfaces.

    PubMed

    Chang, Hochan; Kim, Sungwoong; Jin, Sumin; Lee, Seung-Woo; Yang, Gil-Tae; Lee, Ki-Young; Yi, Hyunjung

    2018-01-10

    Flexible piezoresistive sensors have huge potential for health monitoring, human-machine interfaces, prosthetic limbs, and intelligent robotics. A variety of nanomaterials and structural schemes have been proposed for realizing ultrasensitive flexible piezoresistive sensors. However, despite the success of recent efforts, high sensitivity within narrower pressure ranges and/or the challenging adhesion and stability issues still potentially limit their broad applications. Herein, we introduce a biomaterial-based scheme for the development of flexible pressure sensors that are ultrasensitive (resistance change by 5 orders) over a broad pressure range of 0.1-100 kPa, promptly responsive (20 ms), and yet highly stable. We show that employing biomaterial-incorporated conductive networks of single-walled carbon nanotubes as interfacial layers of contact-based resistive pressure sensors significantly enhances piezoresistive response via effective modulation of the interlayer resistance and provides stable interfaces for the pressure sensors. The developed flexible sensor is capable of real-time monitoring of wrist pulse waves under external medium pressure levels and providing pressure profiles applied by a thumb and a forefinger during object manipulation at a low voltage (1 V) and power consumption (<12 μW). This work provides a new insight into the material candidates and approaches for the development of wearable health-monitoring and human-machine interfaces.

  6. Tunable multimode-interference bandpass fiber filter.

    PubMed

    Antonio-Lopez, J E; Castillo-Guzman, A; May-Arrioja, D A; Selvas-Aguilar, R; Likamwa, P

    2010-02-01

    We report on a wavelength-tunable filter based on multimode interference (MMI) effects. A typical MMI filter consists of a multimode fiber (MMF) spliced between two single-mode fibers (SMF). The peak wavelength response of the filter exhibits a linear dependence when the length of the MMF is modified. Therefore a capillary tube filled with refractive-index-matching liquid is used to effectively increase the length of the MMF, and thus wavelength tuning is achieved. Using this filter a ring-based tunable erbium-doped fiber laser is demonstrated with a tunability of 30 nm, covering the full C-band.

  7. Thyroid hypoechogenicity after methimazole withdrawal in Graves' disease: a useful index for predicting recurrence?

    PubMed

    Zingrillo, M; D'Aloiso, L; Ghiggi, M R; Di Cerbo, A; Chiodini, I; Torlontano, M; Liuzzi, A

    1996-08-01

    A characteristic thyroid ultrasonographic picture with diffuse or scattered low echogenicity has been described in Graves' disease (GD). Thyroid hypoechogenicity in GD at onset has been considered a prognostic index of relapse after medical treatment; moreover, thyroid hypoechogenicity is regularly observed in GD at the onset, but not in patients with 'burned-out' disease. The aim of this study was to evaluate the usefulness of thyroid hypoechogenicity changes in predicting GD relapse. Longitudinal prospective study of previously untreated patients with GD. Thirty-nine consecutive patients aged 10-72 years were treated with methimazole (MMI) for 12-24 months on a titration regimen. Evaluation of patients in remission or with relapse was done 12 and 24 months after MMI withdrawal. Thyroid ultrasonography and TSH receptor antibodies (TRAb) were evaluated in basal conditions and then one month after MMI withdrawal. Thyroid hypoechogenicity score (assessed by the same observer with the same equipment) was graded as: 0 absent; 1 mild; 2 moderate; 3 marked. At the withdrawal evaluation a score < 2 and a TRAb value < 10 U/l were considered as normal. Twelve and 24 months after withdrawal, there were 10 (25.6%) and 17 (44.7%) relapses, respectively. Neither thyroid hypoechogenicity score nor TRAb values evaluated in basal conditions, showed significant differences between patients remaining euthyroid and those who became again hyperthyroid. In the whole group, the thyroid hypoechogenicity score was significantly lower at the withdrawal than in basal conditions (1.1 +/- 1.1 vs 2 +/- 0.8; P < 0.0001); it was significantly lower in patients in remission (P < 0.001), but not in those who relapsed. The thyroid hypoechogenicity score at withdrawal was normal in 23/29 (79.3%) of patients still euthyroid and in 4/10 (40%) of those who relapsed up to the 12th month (P < 0.05); it was normal in 19/21 (90.4%) of patients still euthyroid and in 7/17 (41.2%) of those who relapsed up to the 24th month (P < 0.05). A normal thyroid hypoechogenicity score at withdrawal of MMI had a higher specificity (0.95) and sensitivity (0.59) with respect to TRAb values (0.86 and 0.53, respectively) for the prediction of the relapse of hyperthyroidism at the 24th month. Basal thyroid hypoechogenicity cannot be used as an index of relapse of GD. MMI treatment induces evident changes in thyroid hypoechogenicity, mainly in patients who subsequently go into remission. The absence or a low grade of thyroid hypoechogenicity after MMI treatment seems to be a favourable prognostic index of remission of hyperthyroidism in GD.

  8. ODC-Free Solvent Implementation for Phenolics Cleaning

    NASA Technical Reports Server (NTRS)

    Wurth, Laura; Biegert, Lydia; Lamont, DT; McCool, Alex (Technical Monitor)

    2001-01-01

    During phenolic liner manufacture, resin-impregnated (pre-preg) bias tape of silica, glass, or carbon cloth is tape-wrapped, cured, machined, and then wiped with 1,1,1 tri-chloroethane (TCA) to remove contaminants that may have been introduced during machining and handling. Following the TCA wipe, the machined surface is given a resin wet-coat and over-wrapped with more prepreg and cured. A TCA replacement solvent for these wiping operations must effectively remove both surface contaminants, and sub-surface oils and greases while not compromising the integrity of this interface. Selection of a TCA replacement solvent for phenolic over-wrap interface cleaning began with sub-scale compatibility tests with cured phenolics. Additional compatibility tests included assessment of solvent retention in machined phenolic surfaces. Results from these tests showed that, while the candidate solvent did not degrade the cured phenolics, it was retained in higher concentrations than TCA in phenolic surfaces. This effect was most pronounced with glass and silica cloth phenolics with steep ply angles relative to the wiped surfaces.

  9. Concurrent Image Processing Executive (CIPE)

    NASA Technical Reports Server (NTRS)

    Lee, Meemong; Cooper, Gregory T.; Groom, Steven L.; Mazer, Alan S.; Williams, Winifred I.

    1988-01-01

    The design and implementation of a Concurrent Image Processing Executive (CIPE), which is intended to become the support system software for a prototype high performance science analysis workstation are discussed. The target machine for this software is a JPL/Caltech Mark IIIfp Hypercube hosted by either a MASSCOMP 5600 or a Sun-3, Sun-4 workstation; however, the design will accommodate other concurrent machines of similar architecture, i.e., local memory, multiple-instruction-multiple-data (MIMD) machines. The CIPE system provides both a multimode user interface and an applications programmer interface, and has been designed around four loosely coupled modules; (1) user interface, (2) host-resident executive, (3) hypercube-resident executive, and (4) application functions. The loose coupling between modules allows modification of a particular module without significantly affecting the other modules in the system. In order to enhance hypercube memory utilization and to allow expansion of image processing capabilities, a specialized program management method, incremental loading, was devised. To minimize data transfer between host and hypercube a data management method which distributes, redistributes, and tracks data set information was implemented.

  10. Ultra-low-cost 3D gaze estimation: an intuitive high information throughput compliment to direct brain-machine interfaces

    NASA Astrophysics Data System (ADS)

    Abbott, W. W.; Faisal, A. A.

    2012-08-01

    Eye movements are highly correlated with motor intentions and are often retained by patients with serious motor deficiencies. Despite this, eye tracking is not widely used as control interface for movement in impaired patients due to poor signal interpretation and lack of control flexibility. We propose that tracking the gaze position in 3D rather than 2D provides a considerably richer signal for human machine interfaces by allowing direct interaction with the environment rather than via computer displays. We demonstrate here that by using mass-produced video-game hardware, it is possible to produce an ultra-low-cost binocular eye-tracker with comparable performance to commercial systems, yet 800 times cheaper. Our head-mounted system has 30 USD material costs and operates at over 120 Hz sampling rate with a 0.5-1 degree of visual angle resolution. We perform 2D and 3D gaze estimation, controlling a real-time volumetric cursor essential for driving complex user interfaces. Our approach yields an information throughput of 43 bits s-1, more than ten times that of invasive and semi-invasive brain-machine interfaces (BMIs) that are vastly more expensive. Unlike many BMIs our system yields effective real-time closed loop control of devices (10 ms latency), after just ten minutes of training, which we demonstrate through a novel BMI benchmark—the control of the video arcade game ‘Pong’.

  11. Considerations for human-machine interfaces in tele-operations

    NASA Technical Reports Server (NTRS)

    Newport, Curt

    1991-01-01

    Numerous factors impact on the efficiency of tele-operative manipulative work. Generally, these are related to the physical environment of the tele-operator and how he interfaces with robotic control consoles. The capabilities of the operator can be influenced by considerations such as temperature, eye strain, body fatigue, and boredom created by repetitive work tasks. In addition, the successful combination of man and machine will, in part, be determined by the configuration of the visual and physical interfaces available to the teleoperator. The design and operation of system components such as full-scale and mini-master manipulator controllers, servo joysticks, and video monitors will have a direct impact on operational efficiency. As a result, the local environment and the interaction of the operator with the robotic control console have a substantial effect on mission productivity.

  12. NeuroRex: A Clinical Neural Interface Roadmap for EEG-based Brain Machine Interfaces to a Lower Body Robotic Exoskeleton*

    PubMed Central

    Contreras-Vidal, Jose L.; Grossman, Robert G.

    2013-01-01

    In this communication, a translational clinical brain-machine interface (BMI) roadmap for an EEG-based BMI to a robotic exoskeleton (NeuroRex) is presented. This multi-faceted project addresses important engineering and clinical challenges: It addresses the validation of an intelligent, self-balancing, robotic lower-body and trunk exoskeleton (Rex) augmented with EEG-based BMI capabilities to interpret user intent to assist a mobility-impaired person to walk independently. The goal is to improve the quality of life and health status of wheelchair-bounded persons by enabling standing and sitting, walking and backing, turning, ascending and descending stairs/curbs, and navigating sloping surfaces in a variety of conditions without the need for additional support or crutches. PMID:24110003

  13. Pellet to Part Manufacturing System for CNCs

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Roschli, Alex C.; Love, Lonnie J.; Post, Brian K.

    Oak Ridge National Laboratory’s Manufacturing Demonstration Facility worked with Hybrid Manufacturing Technologies to develop a compact prototype composite additive manufacturing head that can effectively extrude injection molding pellets. The head interfaces with conventional CNC machine tools enabling rapid conversion of conventional machine tools to additive manufacturing tools. The intent was to enable wider adoption of Big Area Additive Manufacturing (BAAM) technology and combine BAAM technology with conventional machining systems.

  14. Biosleeve Human-Machine Interface

    NASA Technical Reports Server (NTRS)

    Assad, Christopher (Inventor)

    2016-01-01

    Systems and methods for sensing human muscle action and gestures in order to control machines or robotic devices are disclosed. One exemplary system employs a tight fitting sleeve worn on a user arm and including a plurality of electromyography (EMG) sensors and at least one inertial measurement unit (IMU). Power, signal processing, and communications electronics may be built into the sleeve and control data may be transmitted wirelessly to the controlled machine or robotic device.

  15. The Python Spectral Analysis Tool (PySAT) for Powerful, Flexible, and Easy Preprocessing and Machine Learning with Point Spectral Data

    NASA Astrophysics Data System (ADS)

    Anderson, R. B.; Finch, N.; Clegg, S. M.; Graff, T.; Morris, R. V.; Laura, J.

    2018-04-01

    The PySAT point spectra tool provides a flexible graphical interface, enabling scientists to apply a wide variety of preprocessing and machine learning methods to point spectral data, with an emphasis on multivariate regression.

  16. Development of sensitized pick coal interface detector system

    NASA Technical Reports Server (NTRS)

    Burchill, R. F.

    1979-01-01

    One approach for detection of the coal interface is measurement of the pick cutting hoads and shock through the use of pick strain gage load cells and accelerometers. The cutting drum of a long wall mining machine contains a number of cutting picks. In order to measure pick loads and shocks, one pick was instrumented and telementry used to transmit the signals from the drum to an instrument-type tape recorder. A data system using FM telemetry was designed to transfer cutting bit load and shock information from the drum of a longwall shearer coal mining machine to a chassis mounted data recorder.

  17. Enhanced/Operator Machine Interface Phase I

    DTIC Science & Technology

    1997-12-22

    investigation proposes an adaptive OMI technique using a cognitive task analysis (CTA) approach derived from research by several experts in the Cognitive...Science field. The research reveals that adaptive interfaces have not been widely implemented due to the difficulty of the cognitive task analysis . Moreover

  18. [Cost-effectiveness of the clinical treatment of Grave's disease in a public University Hospital: a retrospective analysis and prospective projection for a therapeutic approach].

    PubMed

    Lima, Nicolau; Knobel, Meyer; Camargo, Rosalinda Y; Tomimori, Eduardo; Medeiros-Neto, Geraldo

    2005-08-01

    The aim of the present study was to evaluate a new proposal for increasing compliance to the clinical management of patients with Graves' disease (GD) in a large and public University Hospital. The patients were carefully selected (no previous GD treatment, goiter volume less than 6 mL must be living in the metro area of São Paulo), received medication at no cost, were contacted frequently by the social worker and alerted for the date of consultation and only referred to a single endocrinologist during all phases of treatment. We recruited 229 patients with GD that were initially treated with methimazole (MMI--60 mg q.d) in a single daily dose followed by a combination of MMI (20 mg) plus L-T4 (100 microg) daily for 24 months. Only 83 patients (36.2%) completed the protocol and were subdivided in: Group 1 (n= 34) that were in remission for 3 years after discontinuation of the MMI and Group 2 (n= 49) that presented recurrence of GD between 2 and 36 months without MMI. Predictive factors associated with remission were: decrease of the glandular volume, serum TG< 40 ng/mL and normal TRAb values. We concluded that in spite of a careful protocol planned to increase compliance, more than 60% of patients with GD did not complete the therapeutic trial and were referred for radioiodine treatment. The solution for this low therapeutic success for GD should be the possible identification of factors that would indicate patients that are not inclined to follow a long period of clinical therapy.

  19. Chiral spiral waveguides based on MMI crossings: theory and experiments

    NASA Astrophysics Data System (ADS)

    Cherchi, Matteo; Ylinen, Sami; Harjanne, Mikko; Kapulainen, Markku; Vehmas, Tapani; Aalto, Timo

    2016-03-01

    We introduce a novel type of chiral spiral waveguide where the usual waveguide crossings are replaced by 100:0 Multimode Interferometers (MMIs), i.e. 2x2 splitters that couple all the input light in the cross output port. Despite the topological equivalence with the standard configuration, we show how resorting to long MMIs has non-trivial advantages in terms of footprint and propagation length. An accurate analytic model is also introduced to show the impact of nonidealities on the spiral performances, including propagation loss and cross-talk. We have designed and fabricated three chiral spirals on our platform, based on 3 μm thick silicon strip waveguides with 0.13 dB/cm propagation loss, and 1.58 mm long MMIs. The fabricated spirals have 7, 13 and 49 loops respectively, corresponding to the effective lengths 6.6 cm, 12.5 cm and 47.9 cm. The proposed model is successfully applied to the experimental results, highlighting MMI extinction ratio of about 16.5 dB and MMI loss of about 0.08 dB, that are much worse compared to the simulated 50 dB extinction and 0.01 dB loss. This imposes an upper limit to the number of rounds, because light takes shortcuts through the bar MMI ports. Nevertheless, the novel chiral spiral waveguides outperform what is achievable in mainstream silicon photonics platforms based on submicron waveguides in terms of length and propagation losses, and they are promising candidates for the realization of integrated gyroscopes. They can be significantly further improved by replacing the MMIs with adiabatic 100:0 splitters, ensuring lower cross-talk and broader bandwidth.

  20. The incidence of ophthalmopathy after radioiodine therapy for Graves` disease: Prognostic factors and the role of methimazole

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Kung, A.W.C.; Cheng, A.

    1994-08-01

    Radioactive iodine-131 (RAI) has been reported to be associated with a high incidence of development or exacerbation of Graves` ophthalmopathy (GO). This is thought to be associated with a surge of autoantibodies after RAI therapy. The role of methimazole (MMI), which possesses immunomodulatory action, in the prevention of GO was explored by studying 114 patients with Graves` disease. They were assigned randomly to receive either RAI alone or adjunctive antithyroid drugs, which consisted of MMI and L-T{sub 4} as a block-replacement therapy for 12 months and were followed for 2 yr. Thirty-five patients (30.7%) had GO at presentation. Twenty-one (18%)more » patients developed new GO, and six had worsening of preexisting GO. The development of hypothyroidism (P < 0.01) and an elevation of TSH (P < 0.05) were associated with increased risk of development or exacerbation of GO. The chance of development or exacerbation of GO is higher in those with no ophthalmopathy than in those with preexisting GO at presentation (P = 0.002). The incidence of development or exacerbation of GO was similar in the two treatment groups (RAI, 22.8%; adjunctive antithyroid drugs, 23.7%; P = NS). MMI was able to suppress the surge of TSH receptor antibody (TRAB) after RAI, but a surge in TRAB was not of prognostic significance for the development of GO after RAI. Patients who developed or had exacerbation of GO actually had lower TRAB at presentation (P = 0.02). The authors conclude that hypothyroidism with elevated TSH is an important adverse factor for the development or exacerbation of GO, and MMI was unable to prevent the development or exacerbation of GO after RAI. 35 refs., 4 tabs.« less

  1. Mentor-mentee interaction and laboratory social environment: Do they matter in doctoral students' publication productivity?

    PubMed

    Ynalvez, Marcus Antonius; Ynalvez, Ruby A; Ramírez, Enrique

    2017-03-04

    We explored the social shaping of science at the micro-level reality of face-to-face interaction in one of the traditional places for scientific activities-the scientific lab. We specifically examined how doctoral students' perception of their: (i) interaction with doctoral mentors (MMI) and (ii) lab social environment (LSE) influenced productivity. Construed as the production of peer-reviewed articles, we measured productivity using total number of articles (TOTAL), number of articles with impact factor greater than or equal to 4.00 (IFGE4), and number of first-authored articles (NFA). Via face-to-face interviews, we obtained data from n = 210 molecular biology Ph.D. students in selected universities in Japan, Singapore, and Taiwan. Additional productivity data (NFA) were obtained from online bibliometric databases. To summarize the original 13 MMI and 13 LSE semantic-differential items which we used to measure students' perceptions, principal component (PC) analyses were performed. The results were smaller sets of 4 MMI PCs and 4 LSE PCs. To identify which PCs influenced publication counts, we performed Poisson regression analyses. Although perceived MMI was not linked to productivity, perceived LSE was linked: Students who perceived their LSE as intellectually stimulating reported high levels of productivity in both TOTAL and IFGE4, but not in NFA. Our findings not only highlight how students' perception of their training environment factors in the production of scientific output, our findings also carry important implications for improving mentoring programs in science. © 2016 by The International Union of Biochemistry and Molecular Biology, 45(2):130-144, 2017. © 2016 The International Union of Biochemistry and Molecular Biology.

  2. Considerations in comparing the U.S. Geological Survey one‐year induced‐seismicity hazard models with “Did You Feel It?” and instrumental data

    USGS Publications Warehouse

    White, Isabel; Liu, Taojun; Luco, Nicolas; Liel, Abbie

    2017-01-01

    The recent steep increase in seismicity rates in Oklahoma, southern Kansas, and other parts of the central United States led the U.S. Geological Survey (USGS) to develop, for the first time, a probabilistic seismic hazard forecast for one year (2016) that incorporates induced seismicity. In this study, we explore a process to ground‐truth the hazard model by comparing it with two databases of observations: modified Mercalli intensity (MMI) data from the “Did You Feel It?” (DYFI) system and peak ground acceleration (PGA) values from instrumental data. Because the 2016 hazard model was heavily based on earthquake catalogs from 2014 to 2015, this initial comparison utilized observations from these years. Annualized exceedance rates were calculated with the DYFI and instrumental data for direct comparison with the model. These comparisons required assessment of the options for converting hazard model results and instrumental data from PGA to MMI for comparison with the DYFI data. In addition, to account for known differences that affect the comparisons, the instrumental PGA and DYFI data were declustered, and the hazard model was adjusted for local site conditions. With these adjustments, examples at sites with the most data show reasonable agreement in the exceedance rates. However, the comparisons were complicated by the spatial and temporal completeness of the instrumental and DYFI observations. Furthermore, most of the DYFI responses are in the MMI II–IV range, whereas the hazard model is oriented toward forecasts at higher ground‐motion intensities, usually above about MMI IV. Nevertheless, the study demonstrates some of the issues that arise in making these comparisons, thereby informing future efforts to ground‐truth and improve hazard modeling for induced‐seismicity applications.

  3. Characteristics of stroke mechanisms in patients with medullary infarction.

    PubMed

    Lee, M J; Park, Y G; Kim, S J; Lee, J J; Bang, O Y; Kim, J S

    2012-11-01

    Few studies have focused on the mechanisms underlying medullary infarctions. Our aim in this study was to investigate stroke mechanisms in patients with medullary infarctions and to determine the clinical, radiological and laboratory characteristics of these patients with different underlying stroke etiologies. Consecutive patients with medullary infarction were analysed. Stroke mechanisms were classified as large artery disease (LAD), cardiogenic embolism (CE), small vessel disease (SVD), arterial dissection or undetermined etiology. Clinical, radiological and laboratory factors were analysed according to the location of the lesion and stroke mechanisms. A total of 77 patients were enrolled in this study. Amongst them, 53 (68.8%) patients had lateral medullary infarction (LMI), 22 (28.6%) had medial medullary infarction (MMI), and the remaining 2 (2.6%) had hemimedullary infarction. In both LMI and MMI patients, LAD was the most frequently encountered stroke mechanism. Arterial dissection was the second most common cause followed by SVD and CE in patients with LMI, whereas SVD was more frequently observed (P < 0.001) and dissection and CE were less prevalent (P < 0.001 and P = 0.024, respectively) in MMI than in LMI. Regarding differences amongst stroke etiologies, patients with dissection were younger and had a significantly lower incidence of metabolic syndrome (P = 0.002 and P = 0.009, respectively) than patients with LAD and SVD. Patients in the LAD (19/34, 60%) and dissection groups (12/14, 75%) had abnormal perfusion-weighted MRI (PWI) findings, whereas all patients with SVD (9/9) had normal PWI findings (P < 0.001). Stroke mechanisms in medullary infarction differ between LMI and MMI. Clinical and radiological characteristics, especially PWI features, are helpful in discriminating the etiologies of stroke in these patients. © 2012 The Author(s) European Journal of Neurology © 2012 EFNS.

  4. Development of a diatom-based multimetric index for acid mine drainage impacted depressional wetlands.

    PubMed

    Riato, Luisa; Leira, Manel; Della Bella, Valentina; Oberholster, Paul J

    2018-01-15

    Acid mine drainage (AMD) from coal mining in the Mpumalanga Highveld region of South Africa has caused severe chemical and biological degradation of aquatic habitats, specifically depressional wetlands, as mines use these wetlands for storage of AMD. Diatom-based multimetric indices (MMIs) to assess wetland condition have mostly been developed to assess agricultural and urban land use impacts. No diatom MMI of wetland condition has been developed to assess AMD impacts related to mining activities. Previous approaches to diatom-based MMI development in wetlands have not accounted for natural variability. Natural variability among depressional wetlands may influence the accuracy of MMIs. Epiphytic diatom MMIs sensitive to AMD were developed for a range of depressional wetland types to account for natural variation in biological metrics. For this, we classified wetland types based on diatom typologies. A range of 4-15 final metrics were selected from a pool of ~140 candidate metrics to develop the MMIs based on their: (1) broad range, (2) high separation power and (3) low correlation among metrics. Final metrics were selected from three categories: similarity to reference sites, functional groups, and taxonomic composition, which represent different aspects of diatom assemblage structure and function. MMI performances were evaluated according to their precision in distinguishing reference sites, responsiveness to discriminate reference and disturbed sites, sensitivity to human disturbances and relevancy to AMD-related stressors. Each MMI showed excellent discriminatory power, whether or not it accounted for natural variation. However, accounting for variation by grouping sites based on diatom typologies improved overall performance of MMIs. Our study highlights the usefulness of diatom-based metrics and provides a model for the biological assessment of depressional wetland condition in South Africa and elsewhere. Copyright © 2017 Elsevier B.V. All rights reserved.

  5. Soft Material-Enabled, Flexible Hybrid Electronics for Medicine, Healthcare, and Human-Machine Interfaces

    PubMed Central

    Herbert, Robert; Kim, Jong-Hoon; Kim, Yun Soung; Lee, Hye Moon

    2018-01-01

    Flexible hybrid electronics (FHE), designed in wearable and implantable configurations, have enormous applications in advanced healthcare, rapid disease diagnostics, and persistent human-machine interfaces. Soft, contoured geometries and time-dynamic deformation of the targeted tissues require high flexibility and stretchability of the integrated bioelectronics. Recent progress in developing and engineering soft materials has provided a unique opportunity to design various types of mechanically compliant and deformable systems. Here, we summarize the required properties of soft materials and their characteristics for configuring sensing and substrate components in wearable and implantable devices and systems. Details of functionality and sensitivity of the recently developed FHE are discussed with the application areas in medicine, healthcare, and machine interactions. This review concludes with a discussion on limitations of current materials, key requirements for next generation materials, and new application areas. PMID:29364861

  6. A machine for the preliminary investigation of design features influencing the wear behaviour of knee prostheses.

    PubMed

    McGloughlin, T M; Murphy, D M; Kavanagh, A G

    2004-01-01

    Degradation of tibial inserts in vivo has been found to be multifactorial in nature, resulting in a complex interaction of many variables. A range of kinematic conditions occurs at the tibio-femoral interface, giving rise to various degrees of rolling and sliding at this interface. The movement of the tibio-femoral contact point may be an influential factor in the overall wear of ultra-high molecular weight polyethylene (UHMWPE) tibial components. As part of this study a three-station wear-test machine was designed and built to investigate the influence of rolling and sliding on the wear behaviour of specific design aspects of contemporary knee prostheses. Using the machine, it is possible to monitor the effect of various slide roll ratios on the performance of contemporary bearing designs from a geometrical and materials perspective.

  7. Soft Material-Enabled, Flexible Hybrid Electronics for Medicine, Healthcare, and Human-Machine Interfaces.

    PubMed

    Herbert, Robert; Kim, Jong-Hoon; Kim, Yun Soung; Lee, Hye Moon; Yeo, Woon-Hong

    2018-01-24

    Flexible hybrid electronics (FHE), designed in wearable and implantable configurations, have enormous applications in advanced healthcare, rapid disease diagnostics, and persistent human-machine interfaces. Soft, contoured geometries and time-dynamic deformation of the targeted tissues require high flexibility and stretchability of the integrated bioelectronics. Recent progress in developing and engineering soft materials has provided a unique opportunity to design various types of mechanically compliant and deformable systems. Here, we summarize the required properties of soft materials and their characteristics for configuring sensing and substrate components in wearable and implantable devices and systems. Details of functionality and sensitivity of the recently developed FHE are discussed with the application areas in medicine, healthcare, and machine interactions. This review concludes with a discussion on limitations of current materials, key requirements for next generation materials, and new application areas.

  8. Research on ARM Numerical Control System

    NASA Astrophysics Data System (ADS)

    Wei, Xu; JiHong, Chen

    Computerized Numerical Control (CNC) machine tools is the foundation of modern manufacturing systems, whose advanced digital technology is the key to solve the problem of sustainable development of machine tool manufacturing industry. The paper is to design CNC system embedded on ARM and indicates the hardware design and the software systems supported. On the hardware side: the driving chip of the motor control unit, as the core of components, is MCX314AL of DSP motion control which is developed by NOVA Electronics Co., Ltd. of Japan. It make convenient to control machine because of its excellent performance, simple interface, easy programming. On the Software side, the uC/OS-2 is selected as the embedded operating system of the open source, which makes a detailed breakdown of the modules of the CNC system. Those priorities are designed according to their actual requirements. The ways of communication between the module and the interrupt response are so different that it guarantees real-time property and reliability of the numerical control system. Therefore, it not only meets the requirements of the current social precision machining, but has good man-machine interface and network support to facilitate a variety of craftsmen use.

  9. The Neural-fuzzy Thermal Error Compensation Controller on CNC Machining Center

    NASA Astrophysics Data System (ADS)

    Tseng, Pai-Chung; Chen, Shen-Len

    The geometric errors and structural thermal deformation are factors that influence the machining accuracy of Computer Numerical Control (CNC) machining center. Therefore, researchers pay attention to thermal error compensation technologies on CNC machine tools. Some real-time error compensation techniques have been successfully demonstrated in both laboratories and industrial sites. The compensation results still need to be enhanced. In this research, the neural-fuzzy theory has been conducted to derive a thermal prediction model. An IC-type thermometer has been used to detect the heat sources temperature variation. The thermal drifts are online measured by a touch-triggered probe with a standard bar. A thermal prediction model is then derived by neural-fuzzy theory based on the temperature variation and the thermal drifts. A Graphic User Interface (GUI) system is also built to conduct the user friendly operation interface with Insprise C++ Builder. The experimental results show that the thermal prediction model developed by neural-fuzzy theory methodology can improve machining accuracy from 80µm to 3µm. Comparison with the multi-variable linear regression analysis the compensation accuracy is increased from ±10µm to ±3µm.

  10. Software architecture for time-constrained machine vision applications

    NASA Astrophysics Data System (ADS)

    Usamentiaga, Rubén; Molleda, Julio; García, Daniel F.; Bulnes, Francisco G.

    2013-01-01

    Real-time image and video processing applications require skilled architects, and recent trends in the hardware platform make the design and implementation of these applications increasingly complex. Many frameworks and libraries have been proposed or commercialized to simplify the design and tuning of real-time image processing applications. However, they tend to lack flexibility, because they are normally oriented toward particular types of applications, or they impose specific data processing models such as the pipeline. Other issues include large memory footprints, difficulty for reuse, and inefficient execution on multicore processors. We present a novel software architecture for time-constrained machine vision applications that addresses these issues. The architecture is divided into three layers. The platform abstraction layer provides a high-level application programming interface for the rest of the architecture. The messaging layer provides a message-passing interface based on a dynamic publish/subscribe pattern. A topic-based filtering in which messages are published to topics is used to route the messages from the publishers to the subscribers interested in a particular type of message. The application layer provides a repository for reusable application modules designed for machine vision applications. These modules, which include acquisition, visualization, communication, user interface, and data processing, take advantage of the power of well-known libraries such as OpenCV, Intel IPP, or CUDA. Finally, the proposed architecture is applied to a real machine vision application: a jam detector for steel pickling lines.

  11. Network Modeling and Energy-Efficiency Optimization for Advanced Machine-to-Machine Sensor Networks

    PubMed Central

    Jung, Sungmo; Kim, Jong Hyun; Kim, Seoksoo

    2012-01-01

    Wireless machine-to-machine sensor networks with multiple radio interfaces are expected to have several advantages, including high spatial scalability, low event detection latency, and low energy consumption. Here, we propose a network model design method involving network approximation and an optimized multi-tiered clustering algorithm that maximizes node lifespan by minimizing energy consumption in a non-uniformly distributed network. Simulation results show that the cluster scales and network parameters determined with the proposed method facilitate a more efficient performance compared to existing methods. PMID:23202190

  12. Design of conveyor type machine with numerical control for manufacturing of extrusion thermoplastic thread

    NASA Astrophysics Data System (ADS)

    Gorbunova, T. N.; Koltunov, I. I.; Tumanova, M. B.

    2018-05-01

    The article is devoted to the development of a model and control program for a 3D printer working based on extrusion technology. The article contains descriptions of all components of the machine and blocks of the interface of the control program.

  13. FSW of Aluminum Tailor Welded Blanks across Machine Platforms

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Hovanski, Yuri; Upadhyay, Piyush; Carlson, Blair

    2015-02-16

    Development and characterization of friction stir welded aluminum tailor welded blanks was successfully carried out on three separate machine platforms. Each was a commercially available, gantry style, multi-axis machine designed specifically for friction stir welding. Weld parameters were developed to support high volume production of dissimilar thickness aluminum tailor welded blanks at speeds of 3 m/min and greater. Parameters originally developed on an ultra-high stiffness servo driven machine where first transferred to a high stiffness servo-hydraulic friction stir welding machine, and subsequently transferred to a purpose built machine designed to accommodate thin sheet aluminum welding. The inherent beam stiffness, bearingmore » compliance, and control system for each machine were distinctly unique, which posed specific challenges in transferring welding parameters across machine platforms. This work documents the challenges imposed by successfully transferring weld parameters from machine to machine, produced from different manufacturers and with unique control systems and interfaces.« less

  14. An operator interface design for a telerobotic inspection system

    NASA Technical Reports Server (NTRS)

    Kim, Won S.; Tso, Kam S.; Hayati, Samad

    1993-01-01

    The operator interface has recently emerged as an important element for efficient and safe interactions between human operators and telerobotics. Advances in graphical user interface and graphics technologies enable us to produce very efficient operator interface designs. This paper describes an efficient graphical operator interface design newly developed for remote surface inspection at NASA-JPL. The interface, designed so that remote surface inspection can be performed by a single operator with an integrated robot control and image inspection capability, supports three inspection strategies of teleoperated human visual inspection, human visual inspection with automated scanning, and machine-vision-based automated inspection.

  15. The reported incidence of man-machine interface issues in Army aviators using the Aviator's Night Vision System (ANVIS) in a combat theatre

    NASA Astrophysics Data System (ADS)

    Hiatt, Keith L.; Rash, Clarence E.

    2011-06-01

    Background: Army Aviators rely on the ANVIS for night operations. Human factors literature notes that the ANVIS man-machine interface results in reports of visual and spinal complaints. This is the first study that has looked at these issues in the much harsher combat environment. Last year, the authors reported on the statistically significant (p<0.01) increased complaints of visual discomfort, degraded visual cues, and incidence of static and dynamic visual illusions in the combat environment [Proc. SPIE, Vol. 7688, 76880G (2010)]. In this paper we present the findings regarding increased spinal complaints and other man-machine interface issues found in the combat environment. Methods: A survey was administered to Aircrew deployed in support of Operation Enduring Freedom (OEF). Results: 82 Aircrew (representing an aggregate of >89,000 flight hours of which >22,000 were with ANVIS) participated. Analysis demonstrated high complaints of almost all levels of back and neck pain. Additionally, the use of body armor and other Aviation Life Support Equipment (ALSE) caused significant ergonomic complaints when used with ANVIS. Conclusions: ANVIS use in a combat environment resulted in higher and different types of reports of spinal symptoms and other man-machine interface issues over what was previously reported. Data from this study may be more operationally relevant than that of the peacetime literature as it is derived from actual combat and not from training flights, and it may have important implications about making combat predictions based on performance in training scenarios. Notably, Aircrew remarked that they could not execute the mission without ANVIS and ALSE and accepted the degraded ergonomic environment.

  16. Integrated-optic current sensors with a multimode interference waveguide device.

    PubMed

    Kim, Sung-Moon; Chu, Woo-Sung; Kim, Sang-Guk; Oh, Min-Cheol

    2016-04-04

    Optical current sensors based on polarization-rotated reflection interferometry are demonstrated using polymeric integrated optics and various functional optical waveguide devices. Interferometric sensors normally require bias feedback control for maintaining the operating point, which increases the cost. In order to resolve this constraint of feedback control, a multimode interference (MMI) waveguide device is integrated onto the current-sensor optical chip in this work. From the multiple outputs of the MMI, a 90° phase-shifted transfer function is obtained. Using passive quadrature demodulation, we demonstrate that the sensor could maintain the output signal regardless of the drift in the operating bias-point.

  17. Spatial mode filters realized with multimode interference couplers

    NASA Astrophysics Data System (ADS)

    Leuthold, J.; Hess, R.; Eckner, J.; Besse, P. A.; Melchior, H.

    1996-06-01

    Spatial mode filters based on multimode interference couplers (MMI's) that offer the possibility of splitting off antisymmetric from symmetric modes are presented, and realizations of these filters in InGaAsP / InP are demonstrated. Measured suppression of the antisymmetric first-order modes at the output for the symmetric mode is better than 18 dB. Such MMI's are useful for monolithically integrating mode filters with all-optical devices, which are controlled through an antisymmetric first-order mode. The filtering out of optical control signals is necessary for cascading all-optical devices. Another application is the improvement of on-off ratios in optical switches.

  18. The distribution of modified mercalli intensity in the 18 April 1906 San Francisco earthquake

    USGS Publications Warehouse

    Boatwright, J.; Bundock, H.

    2008-01-01

    We analyze Boatwright and Bundock's (2005) modified Mercalli intensity (MMI) map for the 18 April 1906 San Francisco earthquake, reviewing their interpretation of the MMI scale and testing their correlation of 1906 cemetery damage with MMI intensity. We consider in detail four areas of the intensity map where Boatwright and Bundock (2005) added significantly to the intensity descriptions compiled by Lawson (1908). We show that the distribution of off-fault damage in Sonoma County suggests that the rupture velocity approached the P-wave velocity along Tomales Bay. In contrast, the falloff of intensity with distance from the fault appears approximately constant throughout Mendocino County. The intensity in Humboldt County appears somewhat higher than the intensity in Mendocino County, suggesting that the rupture process at the northern end of the rupture was relatively energetic and that there was directivity consistent with a subsonic rupture velocity on the section of the fault south of Shelter Cove. Finally, we show that the intensity sites added in Santa Cruz County change the intensity distribution so that it decreases gradually along the southeastern section of rupture from Corralitos to San Juan Bautista and implies that the stress release on this section of rupture was relatively low.

  19. All-optical universal logic gates on nonlinear multimode interference coupler using tunable input intensity

    NASA Astrophysics Data System (ADS)

    Tajaldini, Mehdi; Jafri, Mohd Zubir Mat

    2015-04-01

    The theory of Nonlinear Modal Propagation Analysis Method (NMPA) have shown significant features of nonlinear multimode interference (MMI) coupler with compact dimension and when launched near the threshold of nonlinearity. Moreover, NMPA have the potential to allow studying the nonlinear MMI based the modal interference to explorer the phenomenon that what happen due to the natural of multimode region. Proposal of all-optical switch based NMPA has approved its capability to achieving the all-optical gates. All-optical gates have attracted increasing attention due to their practical utility in all-optical signal processing networks and systems. Nonlinear multimode interference devices could apply as universal all-optical gates due to significant features that NMPA introduce them. In this Paper, we present a novel Ultra-compact MMI coupler based on NMPA method in low intensity compared to last reports either as a novel design method and potential application for optical NAND, NOR as universal gates on single structure for Boolean logic signal processing devices and optimize their application via studding the contrast ratio between ON and OFF as a function of output width. We have applied NMPA for several applications so that the miniaturization in low nonlinear intensities is their main purpose.

  20. Effect of cloric acid concentration on corrosion behavior of Ni/Cr coated on carbon steel

    NASA Astrophysics Data System (ADS)

    Desiati, Resetiana Dwi; Sugiarti, Eni; Thosin, K. A. Zaini

    2018-05-01

    Corrosion is one of the causes of metal degradation. Carbon steel (Fe) is easy to corrode in the extreme environment. Coating on carbon steel is required to improve corrosion resistance owing to protection or hindrance to extreme environmental conditions. In this present work, carbon steel was coated by electroplating techniques for nickel and pack cementation for chrome. The corrosion rate test was performed by Weight Loss method on FeNiCr, FeNi, FeCr and uncoated Fe as comparator which was dyed in 37% HCl and 25% HCl which had previously been measured dimension and mass. The immersion test result of FeNiCr and FeNi specimen were better than FeCr and uncoated Fe in terms of increasing corrosion resistance. The corrosion rate for 56 hours in 37% HCl for FeNiCr was 1.592 mm/y and FeNi was 3.208 mm/y, FeCr only lasted within 32 hours with corrosion rate was 6.494 mm/y. Surface of the sample after the corrosion test there was pitting, crevice corrosion and alloy cracking caused by chloride. The higher the concentration of HCl the faster the corrosion rate.

  1. Mayaro Virus Infection in Amazonia: A Multimodel Inference Approach to Risk Factor Assessment

    PubMed Central

    de Paula, Vanessa S.; Figueiredo, Luiz T. M.; Braga, Wornei S. M.; Luz, Sérgio L. B.

    2012-01-01

    Background Arboviral diseases are major global public health threats. Yet, our understanding of infection risk factors is, with a few exceptions, considerably limited. A crucial shortcoming is the widespread use of analytical methods generally not suited for observational data – particularly null hypothesis-testing (NHT) and step-wise regression (SWR). Using Mayaro virus (MAYV) as a case study, here we compare information theory-based multimodel inference (MMI) with conventional analyses for arboviral infection risk factor assessment. Methodology/Principal Findings A cross-sectional survey of anti-MAYV antibodies revealed 44% prevalence (n = 270 subjects) in a central Amazon rural settlement. NHT suggested that residents of village-like household clusters and those using closed toilet/latrines were at higher risk, while living in non-village-like areas, using bednets, and owning fowl, pigs or dogs were protective. The “minimum adequate” SWR model retained only residence area and bednet use. Using MMI, we identified relevant covariates, quantified their relative importance, and estimated effect-sizes (β±SE) on which to base inference. Residence area (β Village = 2.93±0.41; β Upland = −0.56±0.33, β Riverbanks = −2.37±0.55) and bednet use (β = −0.95±0.28) were the most important factors, followed by crop-plot ownership (β = 0.39±0.22) and regular use of a closed toilet/latrine (β = 0.19±0.13); domestic animals had insignificant protective effects and were relatively unimportant. The SWR model ranked fifth among the 128 models in the final MMI set. Conclusions/Significance Our analyses illustrate how MMI can enhance inference on infection risk factors when compared with NHT or SWR. MMI indicates that forest crop-plot workers are likely exposed to typical MAYV cycles maintained by diurnal, forest dwelling vectors; however, MAYV might also be circulating in nocturnal, domestic-peridomestic cycles in village-like areas. This suggests either a vector shift (synanthropic mosquitoes vectoring MAYV) or a habitat/habits shift (classical MAYV vectors adapting to densely populated landscapes and nocturnal biting); any such ecological/adaptive novelty could increase the likelihood of MAYV emergence in Amazonia. PMID:23071852

  2. A primer on brain-machine interfaces, concepts, and technology: a key element in the future of functional neurorestoration.

    PubMed

    Lee, Brian; Liu, Charles Y; Apuzzo, Michael L J

    2013-01-01

    Conventionally, the practice of neurosurgery has been characterized by the removal of pathology, congenital or acquired. The emerging complement to the removal of pathology is surgery for the specific purpose of restoration of function. Advents in neuroscience, technology, and the understanding of neural circuitry are creating opportunities to intervene in disease processes in a reparative manner, thereby advancing toward the long-sought-after concept of neurorestoration. Approaching the issue of neurorestoration from a biomedical engineering perspective is the rapidly growing arena of implantable devices. Implantable devices are becoming more common in medicine and are making significant advancements to improve a patient's functional outcome. Devices such as deep brain stimulators, vagus nerve stimulators, and spinal cord stimulators are now becoming more commonplace in neurosurgery as we utilize our understanding of the nervous system to interpret neural activity and restore function. One of the most exciting prospects in neurosurgery is the technologically driven field of brain-machine interface, also known as brain-computer interface, or neuroprosthetics. The successful development of this technology will have far-reaching implications for patients suffering from a great number of diseases, including but not limited to spinal cord injury, paralysis, stroke, or loss of limb. This article provides an overview of the issues related to neurorestoration using implantable devices with a specific focus on brain-machine interface technology. Copyright © 2013 Elsevier Inc. All rights reserved.

  3. Model development, testing and experimentation in a CyberWorkstation for Brain-Machine Interface research.

    PubMed

    Rattanatamrong, Prapaporn; Matsunaga, Andrea; Raiturkar, Pooja; Mesa, Diego; Zhao, Ming; Mahmoudi, Babak; Digiovanna, Jack; Principe, Jose; Figueiredo, Renato; Sanchez, Justin; Fortes, Jose

    2010-01-01

    The CyberWorkstation (CW) is an advanced cyber-infrastructure for Brain-Machine Interface (BMI) research. It allows the development, configuration and execution of BMI computational models using high-performance computing resources. The CW's concept is implemented using a software structure in which an "experiment engine" is used to coordinate all software modules needed to capture, communicate and process brain signals and motor-control commands. A generic BMI-model template, which specifies a common interface to the CW's experiment engine, and a common communication protocol enable easy addition, removal or replacement of models without disrupting system operation. This paper reviews the essential components of the CW and shows how templates can facilitate the processes of BMI model development, testing and incorporation into the CW. It also discusses the ongoing work towards making this process infrastructure independent.

  4. Film riding seals for rotary machines

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Bidkar, Rahul Anil; Sarawate, Neelesh Nandkumar; Wolfe, Christopher Edward

    A seal assembly for a rotary machine is provided. The seal assembly includes multiple sealing device segments disposed circumferentially intermediate to a stationary housing and a rotor. Each of the segments includes a shoe plate with a forward-shoe section and an aft-shoe section having one or more labyrinth teeth therebetween facing the rotor. The sealing device includes a stator interface element having a groove or slot for allowing disposal of a spline seal for preventing segment leakages. The sealing device segment also includes multiple bellow springs or flexures connected to the shoe plate and to the stator interface element. Further,more » the sealing device segments include a secondary seal integrated with the stator interface element at one end and positioned about the multiple bellow springs or flexures and the shoe plate at the other end.« less

  5. [Human machines--mechanical humans? The industrial arrangement of the relation between human being and machine on the basis of psychotechnik and Georg Schlesingers work with disabled soldiers].

    PubMed

    Patzel-Mattern, Katja

    2005-01-01

    The 20th Century is the century of of technical artefacts. With their existance and use they create an artificial reality, within which humans have to position themselves. Psychotechnik is an attempt to enable humans for this positioning. It gained importance in Germany after World War I and had its heyday between 1919 and 1926. On the basis of the activity of the engineer and supporter of Psychotechnik Georg Schlesinger, whose particular interest were disabled soldiers, the essay on hand will investigate the understanding of the body and the human being of Psychotechnik as an applied science. It turned out, that the biggest achievement of Psychotechnik was to establish a new view of the relation between human being and machine. Thus it helped to show that the human-machine-interface is a shapable unit. Psychotechnik sees the human body and its physique as the last instance for the design of machines. Its main concern is to optimize the relation between human being and machine rather than to standardize human beings according to the construction of machines. After her splendid rise during the Weimar Republic and her rapid decline since the late 1920s Psychotechnik nowadays gains scientifical attention as a historical phenomenon. The main attention in the current discourse lies on the aspects conserning philosophy of science: the unity of body and soul, the understanding of the human-machine-interface as a shapable unit and the human being as a last instance of this unit.

  6. Digital Systems Validation Handbook. Volume 2. Chapter 19. Pilot - Vehicle Interface

    DTIC Science & Technology

    1993-11-01

    checklists, and other status messages. Voice interactive systems are defi-ed as "the interface between a cooperative human and a machine, which involv -he...Pilot-Vehicle Interface 19-85 5.6.1 Crew Interaction and the Cockpit 19-85 5.6.2 Crew Resource Management and Safety 19-87 5.6.3 Pilot and Crew Training...systems was a "stand-alone" component performing its intended function. Systems and their cockpit interfaces were added as technological advances were

  7. Sustainable cooling method for machining titanium alloy

    NASA Astrophysics Data System (ADS)

    Boswell, B.; Islam, M. N.

    2016-02-01

    Hard to machine materials such as Titanium Alloy TI-6AI-4V Grade 5 are notoriously known to generate high temperatures and adverse reactions between the workpiece and the tool tip materials. These conditions all contribute to an increase in the wear mechanisms, reducing tool life. Titanium Alloy, for example always requires coolant to be used during machining. However, traditional flood cooling needs to be replaced due to environmental issues, and an alternative cooling method found that has minimum impact on the environment. For true sustainable cooling of the tool it is necessary to account for all energy used in the cooling process, including the energy involved in producing the coolant. Previous research has established that efficient cooling of the tool interface improves the tool life and cutting action. The objective of this research is to determine the most appropriate sustainable cooling method that can also reduce the rate of wear at the tool interface.

  8. Human factors in space telepresence

    NASA Technical Reports Server (NTRS)

    Akin, D. L.; Howard, R. D.; Oliveria, J. S.

    1983-01-01

    The problems of interfacing a human with a teleoperation system, for work in space are discussed. Much of the information presented here is the result of experience gained by the M.I.T. Space Systems Laboratory during the past two years of work on the ARAMIS (Automation, Robotics, and Machine Intelligence Systems) project. Many factors impact the design of the man-machine interface for a teleoperator. The effects of each are described in turn. An annotated bibliography gives the key references that were used. No conclusions are presented as a best design, since much depends on the particular application desired, and the relevant technology is swiftly changing.

  9. PubMed Central

    Solazzi, Massimiliano; Loconsole, Claudio; Barsotti, Michele

    2016-01-01

    This paper illustrates the application of emerging technologies and human-machine interfaces to the neurorehabilitation and motor assistance fields. The contribution focuses on wearable technologies and in particular on robotic exoskeleton as tools for increasing freedom to move and performing Activities of Daily Living (ADLs). This would result in a deep improvement in quality of life, also in terms of improved function of internal organs and general health status. Furthermore, the integration of these robotic systems with advanced bio-signal driven human-machine interface can increase the degree of participation of patient in robotic training allowing to recognize user's intention and assisting the patient in rehabilitation tasks, thus representing a fundamental aspect to elicit motor learning PMID:28484314

  10. Teleoperator system man-machine interface requirements for satellite retrieval and satellite servicing. Volume 1: Requirements

    NASA Technical Reports Server (NTRS)

    Malone, T. B.

    1972-01-01

    Requirements were determined analytically for the man machine interface for a teleoperator system performing on-orbit satellite retrieval and servicing. Requirements are basically of two types; mission/system requirements, and design requirements or design criteria. Two types of teleoperator systems were considered: a free flying vehicle, and a shuttle attached manipulator. No attempt was made to evaluate the relative effectiveness or efficiency of the two system concepts. The methodology used entailed an application of the Essex Man-Systems analysis technique as well as a complete familiarization with relevant work being performed at government agencies and by private industry.

  11. Spikes, Local Field Potentials, and Electrocorticogram Characterization during Motor Learning in Rats for Brain Machine Interface Tasks.

    PubMed

    Marzullo, T C; Dudley, J R; Miller, C R; Trejo, L; Kipke, D R

    2005-01-01

    Brain machine interface development typically falls into two arenas, invasive extracellular recording and non-invasive electroencephalogram recording methods. The relationship between action potentials and field potentials is not well understood, and investigation of interrelationships may improve design of neuroprosthetic control systems. Rats were trained on a motor learning task whereby they had to insert their noses into an aperture while simultaneously pressing down on levers with their forepaws; spikes, local field potentials (LFPs), and electrocorticograms (ECoGs) over the motor cortex were recorded and characterized. Preliminary results suggest that the LFP activity in lower cortical layers oscillates with the ECoG.

  12. Quadcopter control using a BCI

    NASA Astrophysics Data System (ADS)

    Rosca, S.; Leba, M.; Ionica, A.; Gamulescu, O.

    2018-01-01

    The paper presents how there can be interconnected two ubiquitous elements nowadays. On one hand, the drones, which are increasingly present and integrated into more and more fields of activity, beyond the military applications they come from, moving towards entertainment, real-estate, delivery and so on. On the other hand, unconventional man-machine interfaces, which are generous topics to explore now and in the future. Of these, we chose brain computer interface (BCI), which allows human-machine interaction without requiring any moving elements. The research consists of mathematical modeling and numerical simulation of a drone and a BCI. Then there is presented an application using a Parrot mini-drone and an Emotiv Insight BCI.

  13. Operating Comfort Prediction Model of Human-Machine Interface Layout for Cabin Based on GEP.

    PubMed

    Deng, Li; Wang, Guohua; Chen, Bo

    2015-01-01

    In view of the evaluation and decision-making problem of human-machine interface layout design for cabin, the operating comfort prediction model is proposed based on GEP (Gene Expression Programming), using operating comfort to evaluate layout scheme. Through joint angles to describe operating posture of upper limb, the joint angles are taken as independent variables to establish the comfort model of operating posture. Factor analysis is adopted to decrease the variable dimension; the model's input variables are reduced from 16 joint angles to 4 comfort impact factors, and the output variable is operating comfort score. The Chinese virtual human body model is built by CATIA software, which will be used to simulate and evaluate the operators' operating comfort. With 22 groups of evaluation data as training sample and validation sample, GEP algorithm is used to obtain the best fitting function between the joint angles and the operating comfort; then, operating comfort can be predicted quantitatively. The operating comfort prediction result of human-machine interface layout of driller control room shows that operating comfort prediction model based on GEP is fast and efficient, it has good prediction effect, and it can improve the design efficiency.

  14. SVM Classifier - a comprehensive java interface for support vector machine classification of microarray data.

    PubMed

    Pirooznia, Mehdi; Deng, Youping

    2006-12-12

    Graphical user interface (GUI) software promotes novelty by allowing users to extend the functionality. SVM Classifier is a cross-platform graphical application that handles very large datasets well. The purpose of this study is to create a GUI application that allows SVM users to perform SVM training, classification and prediction. The GUI provides user-friendly access to state-of-the-art SVM methods embodied in the LIBSVM implementation of Support Vector Machine. We implemented the java interface using standard swing libraries. We used a sample data from a breast cancer study for testing classification accuracy. We achieved 100% accuracy in classification among the BRCA1-BRCA2 samples with RBF kernel of SVM. We have developed a java GUI application that allows SVM users to perform SVM training, classification and prediction. We have demonstrated that support vector machines can accurately classify genes into functional categories based upon expression data from DNA microarray hybridization experiments. Among the different kernel functions that we examined, the SVM that uses a radial basis kernel function provides the best performance. The SVM Classifier is available at http://mfgn.usm.edu/ebl/svm/.

  15. Optimal input selection for neural machine interfaces predicting multiple non-explicit outputs.

    PubMed

    Krepkovich, Eileen T; Perreault, Eric J

    2008-01-01

    This study implemented a novel algorithm that optimally selects inputs for neural machine interface (NMI) devices intended to control multiple outputs and evaluated its performance on systems lacking explicit output. NMIs often incorporate signals from multiple physiological sources and provide predictions for multidimensional control, leading to multiple-input multiple-output systems. Further, NMIs often are used with subjects who have motor disabilities and thus lack explicit motor outputs. Our algorithm was tested on simulated multiple-input multiple-output systems and on electromyogram and kinematic data collected from healthy subjects performing arm reaches. Effects of output noise in simulated systems indicated that the algorithm could be useful for systems with poor estimates of the output states, as is true for systems lacking explicit motor output. To test efficacy on physiological data, selection was performed using inputs from one subject and outputs from a different subject. Selection was effective for these cases, again indicating that this algorithm will be useful for predictions where there is no motor output, as often is the case for disabled subjects. Further, prediction results generalized for different movement types not used for estimation. These results demonstrate the efficacy of this algorithm for the development of neural machine interfaces.

  16. Operating Comfort Prediction Model of Human-Machine Interface Layout for Cabin Based on GEP

    PubMed Central

    Wang, Guohua; Chen, Bo

    2015-01-01

    In view of the evaluation and decision-making problem of human-machine interface layout design for cabin, the operating comfort prediction model is proposed based on GEP (Gene Expression Programming), using operating comfort to evaluate layout scheme. Through joint angles to describe operating posture of upper limb, the joint angles are taken as independent variables to establish the comfort model of operating posture. Factor analysis is adopted to decrease the variable dimension; the model's input variables are reduced from 16 joint angles to 4 comfort impact factors, and the output variable is operating comfort score. The Chinese virtual human body model is built by CATIA software, which will be used to simulate and evaluate the operators' operating comfort. With 22 groups of evaluation data as training sample and validation sample, GEP algorithm is used to obtain the best fitting function between the joint angles and the operating comfort; then, operating comfort can be predicted quantitatively. The operating comfort prediction result of human-machine interface layout of driller control room shows that operating comfort prediction model based on GEP is fast and efficient, it has good prediction effect, and it can improve the design efficiency. PMID:26448740

  17. Review of "Conceptual Structures: Information Processing in Mind and Machine."

    ERIC Educational Resources Information Center

    Smoliar, Stephen W.

    This review of the book, "Conceptual Structures: Information Processing in Mind and Machine," by John F. Sowa, argues that anyone who plans to get involved with issues of knowledge representation should have at least a passing acquaintance with Sowa's conceptual graphs for a database interface. (Used to model the underlying semantics of…

  18. Gesture-controlled interfaces for self-service machines and other applications

    NASA Technical Reports Server (NTRS)

    Cohen, Charles J. (Inventor); Jacobus, Charles J. (Inventor); Paul, George (Inventor); Beach, Glenn (Inventor); Foulk, Gene (Inventor); Obermark, Jay (Inventor); Cavell, Brook (Inventor)

    2004-01-01

    A gesture recognition interface for use in controlling self-service machines and other devices is disclosed. A gesture is defined as motions and kinematic poses generated by humans, animals, or machines. Specific body features are tracked, and static and motion gestures are interpreted. Motion gestures are defined as a family of parametrically delimited oscillatory motions, modeled as a linear-in-parameters dynamic system with added geometric constraints to allow for real-time recognition using a small amount of memory and processing time. A linear least squares method is preferably used to determine the parameters which represent each gesture. Feature position measure is used in conjunction with a bank of predictor bins seeded with the gesture parameters, and the system determines which bin best fits the observed motion. Recognizing static pose gestures is preferably performed by localizing the body/object from the rest of the image, describing that object, and identifying that description. The disclosure details methods for gesture recognition, as well as the overall architecture for using gesture recognition to control of devices, including self-service machines.

  19. Performance Comparison of a Matrix Solver on a Heterogeneous Network Using Two Implementations of MPI: MPICH and LAM

    NASA Technical Reports Server (NTRS)

    Phillips, Jennifer K.

    1995-01-01

    Two of the current and most popular implementations of the Message-Passing Standard, Message Passing Interface (MPI), were contrasted: MPICH by Argonne National Laboratory, and LAM by the Ohio Supercomputer Center at Ohio State University. A parallel skyline matrix solver was adapted to be run in a heterogeneous environment using MPI. The Message-Passing Interface Forum was held in May 1994 which lead to a specification of library functions that implement the message-passing model of parallel communication. LAM, which creates it's own environment, is more robust in a highly heterogeneous network. MPICH uses the environment native to the machine architecture. While neither of these free-ware implementations provides the performance of native message-passing or vendor's implementations, MPICH begins to approach that performance on the SP-2. The machines used in this study were: IBM RS6000, 3 Sun4, SGI, and the IBM SP-2. Each machine is unique and a few machines required specific modifications during the installation. When installed correctly, both implementations worked well with only minor problems.

  20. Intelligent Adaptive Interface: A Design Tool for Enhancing Human-Machine System Performances

    DTIC Science & Technology

    2009-10-01

    and customizable. Thus, an intelligent interface should tailor its parameters to certain prescribed specifications or convert itself and adjust to...Computer Interaction 3(2): 87-122. [51] Schereiber, G., Akkermans, H., Anjewierden, A., de Hoog , R., Shadbolt, N., Van de Velde, W., & Wielinga, W

  1. Goal Tracking in a Natural Language Interface: Towards Achieving Adjustable Autonomy

    DTIC Science & Technology

    1999-01-01

    communication , we believe that human/machine interfaces that share some of the characteristics of human- human communication can be friendlier and easier...natural means of communicating with a mobile robot. Although we are not claiming that communication with robotic agents must be patterned after human

  2. A natural language interface to databases

    NASA Technical Reports Server (NTRS)

    Ford, D. R.

    1988-01-01

    The development of a Natural Language Interface which is semantic-based and uses Conceptual Dependency representation is presented. The system was developed using Lisp and currently runs on a Symbolics Lisp machine. A key point is that the parser handles morphological analysis, which expands its capabilities of understanding more words.

  3. Toward FRP-Based Brain-Machine Interfaces—Single-Trial Classification of Fixation-Related Potentials

    PubMed Central

    Finke, Andrea; Essig, Kai; Marchioro, Giuseppe; Ritter, Helge

    2016-01-01

    The co-registration of eye tracking and electroencephalography provides a holistic measure of ongoing cognitive processes. Recently, fixation-related potentials have been introduced to quantify the neural activity in such bi-modal recordings. Fixation-related potentials are time-locked to fixation onsets, just like event-related potentials are locked to stimulus onsets. Compared to existing electroencephalography-based brain-machine interfaces that depend on visual stimuli, fixation-related potentials have the advantages that they can be used in free, unconstrained viewing conditions and can also be classified on a single-trial level. Thus, fixation-related potentials have the potential to allow for conceptually different brain-machine interfaces that directly interpret cortical activity related to the visual processing of specific objects. However, existing research has investigated fixation-related potentials only with very restricted and highly unnatural stimuli in simple search tasks while participant’s body movements were restricted. We present a study where we relieved many of these restrictions while retaining some control by using a gaze-contingent visual search task. In our study, participants had to find a target object out of 12 complex and everyday objects presented on a screen while the electrical activity of the brain and eye movements were recorded simultaneously. Our results show that our proposed method for the classification of fixation-related potentials can clearly discriminate between fixations on relevant, non-relevant and background areas. Furthermore, we show that our classification approach generalizes not only to different test sets from the same participant, but also across participants. These results promise to open novel avenues for exploiting fixation-related potentials in electroencephalography-based brain-machine interfaces and thus providing a novel means for intuitive human-machine interaction. PMID:26812487

  4. Cooperative processing user interfaces for AdaNET

    NASA Technical Reports Server (NTRS)

    Gutzmann, Kurt M.

    1991-01-01

    A cooperative processing user interface (CUI) system shares the task of graphical display generation and presentation between the user's computer and a remote host. The communications link between the two computers is typically a modem or Ethernet. The two main purposes of a CUI are reduction of the amount of data transmitted between user and host machines, and provision of a graphical user interface system to make the system easier to use.

  5. A novel EOG/EEG hybrid human-machine interface adopting eye movements and ERPs: application to robot control.

    PubMed

    Ma, Jiaxin; Zhang, Yu; Cichocki, Andrzej; Matsuno, Fumitoshi

    2015-03-01

    This study presents a novel human-machine interface (HMI) based on both electrooculography (EOG) and electroencephalography (EEG). This hybrid interface works in two modes: an EOG mode recognizes eye movements such as blinks, and an EEG mode detects event related potentials (ERPs) like P300. While both eye movements and ERPs have been separately used for implementing assistive interfaces, which help patients with motor disabilities in performing daily tasks, the proposed hybrid interface integrates them together. In this way, both the eye movements and ERPs complement each other. Therefore, it can provide a better efficiency and a wider scope of application. In this study, we design a threshold algorithm that can recognize four kinds of eye movements including blink, wink, gaze, and frown. In addition, an oddball paradigm with stimuli of inverted faces is used to evoke multiple ERP components including P300, N170, and VPP. To verify the effectiveness of the proposed system, two different online experiments are carried out. One is to control a multifunctional humanoid robot, and the other is to control four mobile robots. In both experiments, the subjects can complete tasks effectively by using the proposed interface, whereas the best completion time is relatively short and very close to the one operated by hand.

  6. ClearTK 2.0: Design Patterns for Machine Learning in UIMA

    PubMed Central

    Bethard, Steven; Ogren, Philip; Becker, Lee

    2014-01-01

    ClearTK adds machine learning functionality to the UIMA framework, providing wrappers to popular machine learning libraries, a rich feature extraction library that works across different classifiers, and utilities for applying and evaluating machine learning models. Since its inception in 2008, ClearTK has evolved in response to feedback from developers and the community. This evolution has followed a number of important design principles including: conceptually simple annotator interfaces, readable pipeline descriptions, minimal collection readers, type system agnostic code, modules organized for ease of import, and assisting user comprehension of the complex UIMA framework. PMID:29104966

  7. ClearTK 2.0: Design Patterns for Machine Learning in UIMA.

    PubMed

    Bethard, Steven; Ogren, Philip; Becker, Lee

    2014-05-01

    ClearTK adds machine learning functionality to the UIMA framework, providing wrappers to popular machine learning libraries, a rich feature extraction library that works across different classifiers, and utilities for applying and evaluating machine learning models. Since its inception in 2008, ClearTK has evolved in response to feedback from developers and the community. This evolution has followed a number of important design principles including: conceptually simple annotator interfaces, readable pipeline descriptions, minimal collection readers, type system agnostic code, modules organized for ease of import, and assisting user comprehension of the complex UIMA framework.

  8. Hybrid optofluidic biosensors

    NASA Astrophysics Data System (ADS)

    Parks, Joshua W.

    Optofluidics, born of the desire to create a system containing microfluidic environments with integrated optical elements, has seen dramatic increases in popularity over the last 10 years. In particular, the application of this technology towards chip based molecular sensors has undergone significant development. The most sensitive of these biosensors interface liquid- and solid-core antiresonant reflecting optical waveguides (ARROWs). These sensor chips are created using conventional silicon microfabrication. As such, ARROW technology has previously been unable to utilize state-of-the-art microfluidic developments because the technology used--soft polydimethyl siloxane (PDMS) micromolded chips--is unamenable to the silicon microfabrication workflows implemented in the creation of ARROW detection chips. The original goal of this thesis was to employ hybrid integration, or the connection of independently designed and fabricated optofluidic and microfluidic chips, to create enhanced biosensors with the capability of processing and detecting biological samples on a single hybrid system. After successful demonstration of this paradigm, this work expanded into a new direction--direct integration of sensing and detection technologies on a new platform with dynamic, multi-dimensional photonic re-configurability. This thesis reports a number of firsts, including: • 1,000 fold optical transmission enhancement of ARROW optofluidic detection chips through thermal annealing, • Detection of single nucleic acids on a silicon-based ARROW chip, • Hybrid optofluidic integration of ARROW detection chips and passive PDMS microfluidic chips, • Hybrid optofluidic integration of ARROW detection chips and actively controllable PDMS microfluidic chips with integrated microvalves, • On-chip concentration and detection of clinical Ebola nucleic acids, • Multimode interference (MMI) waveguide based wavelength division multiplexing for detection of single influenza virions, • All PDMS platform created from monolithically integrated solid- and liquid-core waveguides with single particle detection efficiency and directly integrated microvalves, featuring: ∘ Tunable/tailorable PDMS MMI waveguides, ∘ Lightvalves (optical switch/fluidic microvalve) with the ability to dynamically control light and fluid flow simultaneously, ∘ Lightvalve trap architecture with the ability to physically trap, detect, and analyze single biomolecules.

  9. ODISEES: A New Paradigm in Data Access

    NASA Astrophysics Data System (ADS)

    Huffer, E.; Little, M. M.; Kusterer, J.

    2013-12-01

    As part of its ongoing efforts to improve access to data, the Atmospheric Science Data Center has developed a high-precision Earth Science domain ontology (the 'ES Ontology') implemented in a graph database ('the Semantic Metadata Repository') that is used to store detailed, semantically-enhanced, parameter-level metadata for ASDC data products. The ES Ontology provides the semantic infrastructure needed to drive the ASDC's Ontology-Driven Interactive Search Environment for Earth Science ('ODISEES'), a data discovery and access tool, and will support additional data services such as analytics and visualization. The ES ontology is designed on the premise that naming conventions alone are not adequate to provide the information needed by prospective data consumers to assess the suitability of a given dataset for their research requirements; nor are current metadata conventions adequate to support seamless machine-to-machine interactions between file servers and end-user applications. Data consumers need information not only about what two data elements have in common, but also about how they are different. End-user applications need consistent, detailed metadata to support real-time data interoperability. The ES ontology is a highly precise, bottom-up, queriable model of the Earth Science domain that focuses on critical details about the measurable phenomena, instrument techniques, data processing methods, and data file structures. Earth Science parameters are described in detail in the ES Ontology and mapped to the corresponding variables that occur in ASDC datasets. Variables are in turn mapped to well-annotated representations of the datasets that they occur in, the instrument(s) used to create them, the instrument platforms, the processing methods, etc., creating a linked-data structure that allows both human and machine users to access a wealth of information critical to understanding and manipulating the data. The mappings are recorded in the Semantic Metadata Repository as RDF-triples. An off-the-shelf Ontology Development Environment and a custom Metadata Conversion Tool comprise a human-machine/machine-machine hybrid tool that partially automates the creation of metadata as RDF-triples by interfacing with existing metadata repositories and providing a user interface that solicits input from a human user, when needed. RDF-triples are pushed to the Ontology Development Environment, where a reasoning engine executes a series of inference rules whose antecedent conditions can be satisfied by the initial set of RDF-triples, thereby generating the additional detailed metadata that is missing in existing repositories. A SPARQL Endpoint, a web-based query service and a Graphical User Interface allow prospective data consumers - even those with no familiarity with NASA data products - to search the metadata repository to find and order data products that meet their exact specifications. A web-based API will provide an interface for machine-to-machine transactions.

  10. Using machine learning to emulate human hearing for predictive maintenance of equipment

    NASA Astrophysics Data System (ADS)

    Verma, Dinesh; Bent, Graham

    2017-05-01

    At the current time, interfaces between humans and machines use only a limited subset of senses that humans are capable of. The interaction among humans and computers can become much more intuitive and effective if we are able to use more senses, and create other modes of communicating between them. New machine learning technologies can make this type of interaction become a reality. In this paper, we present a framework for a holistic communication between humans and machines that uses all of the senses, and discuss how a subset of this capability can allow machines to talk to humans to indicate their health for various tasks such as predictive maintenance.

  11. Diamond turning machine controller implementation

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Garrard, K.P.; Taylor, L.W.; Knight, B.F.

    The standard controller for a Pnuemo ASG 2500 Diamond Turning Machine, an Allen Bradley 8200, has been replaced with a custom high-performance design. This controller consists of four major components. Axis position feedback information is provided by a Zygo Axiom 2/20 laser interferometer with 0.1 micro-inch resolution. Hardware interface logic couples the computers digital and analog I/O channels to the diamond turning machine`s analog motor controllers, the laser interferometer, and other machine status and control information. It also provides front panel switches for operator override of the computer controller and implement the emergency stop sequence. The remaining two components, themore » control computer hardware and software, are discussed in detail below.« less

  12. Interfacing insect brain for space applications.

    PubMed

    Di Pino, Giovanni; Seidl, Tobias; Benvenuto, Antonella; Sergi, Fabrizio; Campolo, Domenico; Accoto, Dino; Maria Rossini, Paolo; Guglielmelli, Eugenio

    2009-01-01

    Insects exhibit remarkable navigation capabilities that current control architectures are still far from successfully mimic and reproduce. In this chapter, we present the results of a study on conceptualizing insect/machine hybrid controllers for improving autonomy of exploratory vehicles. First, the different principally possible levels of interfacing between insect and machine are examined followed by a review of current approaches towards hybridity and enabling technologies. Based on the insights of this activity, we propose a double hybrid control architecture which hinges around the concept of "insect-in-a-cockpit." It integrates both biological/artificial (insect/robot) modules and deliberative/reactive behavior. The basic assumption is that "low-level" tasks are managed by the robot, while the "insect intelligence" is exploited whenever high-level problem solving and decision making is required. Both neural and natural interfacing have been considered to achieve robustness and redundancy of exchanged information.

  13. Man-machine interfaces in LACIE/ERIPS

    NASA Technical Reports Server (NTRS)

    Duprey, B. B. (Principal Investigator)

    1979-01-01

    One of the most important aspects of the interactive portion of the LACIE/ERIPS software system is the way in which the analysis and decision-making capabilities of a human being are integrated with the speed and accuracy of a computer to produce a powerful analysis system. The three major man-machine interfaces in the system are (1) the use of menus for communications between the software and the interactive user; (2) the checkpoint/restart facility to recreate in one job the internal environment achieved in an earlier one; and (3) the error recovery capability which would normally cause job termination. This interactive system, which executes on an IBM 360/75 mainframe, was adapted for use in noninteractive (batch) mode. A case study is presented to show how the interfaces work in practice by defining some fields based on an image screen display, noting the field definitions, and obtaining a film product of the classification map.

  14. Detecting Mental States by Machine Learning Techniques: The Berlin Brain-Computer Interface

    NASA Astrophysics Data System (ADS)

    Blankertz, Benjamin; Tangermann, Michael; Vidaurre, Carmen; Dickhaus, Thorsten; Sannelli, Claudia; Popescu, Florin; Fazli, Siamac; Danóczy, Márton; Curio, Gabriel; Müller, Klaus-Robert

    The Berlin Brain-Computer Interface Brain-Computer Interface (BBCI) uses a machine learning approach to extract user-specific patterns from high-dimensional EEG-features optimized for revealing the user's mental state. Classical BCI applications are brain actuated tools for patients such as prostheses (see Section 4.1) or mental text entry systems ([1] and see [2-5] for an overview on BCI). In these applications, the BBCI uses natural motor skills of the users and specifically tailored pattern recognition algorithms for detecting the user's intent. But beyond rehabilitation, there is a wide range of possible applications in which BCI technology is used to monitor other mental states, often even covert ones (see also [6] in the fMRI realm). While this field is still largely unexplored, two examples from our studies are exemplified in Sections 4.3 and 4.4.

  15. A Graphical Operator Interface for a Telerobotic Inspection System

    NASA Technical Reports Server (NTRS)

    Kim, W. S.; Tso, K. S.; Hayati, S.

    1993-01-01

    Operator interface has recently emerged as an important element for efficient and safe operatorinteractions with the telerobotic system. Recent advances in graphical user interface (GUI) andgraphics/video merging technologies enable development of more efficient, flexible operatorinterfaces. This paper describes an advanced graphical operator interface newly developed for aremote surface inspection system at Jet Propulsion Laboratory. The interface has been designed sothat remote surface inspection can be performed by a single operator with an integrated robot controland image inspection capability. It supports three inspection strategies of teleoperated human visual inspection, human visual inspection with automated scanning, and machine-vision-based automated inspection.

  16. Interplate locking derived from seafloor geodetic measurement at the shallow subduction zone of the northernmost Suruga Trough, Japan

    NASA Astrophysics Data System (ADS)

    Yasuda, K.; Tadokoro, K.; Ikuta, R.; Watanabe, T.; Nagai, S.; Sayanagi, K.

    2013-12-01

    Observation of seafloor crustal deformation is crucial for megathrust earthquake because most of the focal areas are located below seafloor. Seafloor crustal deformation can be observed GPS/Acoustic technique, and this technique has been carried out at subduction margins in Japan, e.g., Japan Trench, Suruga Trough, and Nankai Trough. At the present, the accuracy of seafloor positioning is one to several centimeters for each epoch. Velocity vectors at seafloor site are estimated through repeated observations. Co- and post- seismic slip distribution and interseismic deformation are estimated from results of seafloor geodetic measurement (e.g., Iinuma et al., 2012; Tadokoro et al., 2012). We repeatedly observed seafloor crustal deformations at two sites across the Suruga Trough from 2005 to investigate interplate locking condition at the focal area of the anticipated megathrust, Tokai, earthquake. We observed 12 and 16 times at an east site of the Suruga Trough (SNE) and at an west site of the Suruga Trough (SNW), respectively. We reinstalled seafloor benchmarks at both sites because of run out of batteries in 2012. We calculated and removed the bias between the old and new seafloor benchmarks. Furthermore, we evaluated two type of analysis. One is Fixed triangular configuration Analysis (FTA). When we determine the seafloor benchmark position, we fix the triangular configuration of seafloor units averaging all the measurements to improve trade-off relation between seafloor benchmark position and sound speed structure. Sound speed structure is assumed to be horizontal layered structure. The other one is Fixed Triangle and Gradient structure of sound speed structure (FTGA). We fixed triangular configuration same as FTA. Sound speed structure is assumed to have gradient structure. Comparing FTA with FTGA, the RMS of horizontal position analyzed through FTA is smaller than that through FTGA at SNE site. On the other hand, the RMS of horizontal position analyzed through FTA is larger than that through FTGA at SNW site. We estimated the displacement velocities with relative to the Amurian plate from the result of repeated observation. The estimated displacement velocity vectors at SNE and SNW are 42×8 mm/y to N94W direction and 46×13 mm/y to N77W direction, respectively. The directions are the same as those measured at the on-land GPS stations. The magnitudes of velocity vector indicate significant shortening by approximately 11 mm/y between SNW and on-land GPS stations at the western part of the Suruga Trough. We also calculated the theoretical surface deformation pattern to depict the interplate locking condition. These results show that the plate interface at the shallow zone of the northernmost Suruga trough is strongly locked.

  17. Hydrodynamic stability and Ti-tracer distribution in low-adiabat OMEGA direct-drive implosions

    NASA Astrophysics Data System (ADS)

    Joshi, Tirtha R.

    We discuss the hydrodynamic stability of low-adiabat OMEGA direct-drive implosions based on results obtained from simultaneous emission and absorption spectroscopy of a titanium tracer added to the target. The targets were deuterium filled, warm plastic shells of varying thicknesses and filling gas pressures with a submicron Ti-doped tracer layer initially located on the inner surface of the shell. The spectral features from the titanium tracer are observed during the deceleration and stagnation phases of the implosion, and recorded with a time integrated spectrometer (XRS1), streaked crystal spectrometer (SSCA) and three gated, multi-monochromatic X-ray imager (MMI) instruments fielded along quasi-orthogonal lines-of-sight. The time-integrated, streaked and gated data show simultaneous emission and absorption spectral features associated with titanium K-shell line transitions but only the MMI data provides spatially resolved information. The arrays of gated spectrally resolved images recorded with MMI were processed to obtain spatially resolved spectra characteristic of annular contour regions on the image. A multi-zone spectroscopic analysis of the annular spatially resolved spectra permits the extraction of plasma conditions in the core as well as the spatial distribution of tracer atoms. In turn, the titanium atom distribution provides direct evidence of tracer penetration into the core and thus of the hydrodynamic stability of the shell. The observations, timing and analysis indicate that during fuel burning the titanium atoms have migrated deep into the core and thus shell material mixing is likely to impact the rate of nuclear fusion reactions, i.e. burning rate, and the neutron yield of the implosion. We have found that the Ti atom number density decreases towards the center in early deceleration phase, but later in time the trend is just opposite, i.e., it increases towards the center of the implosion core. This is in part a consequence of the convergent effect of spherical geometry. The spatial profiles of Ti areal densities in the implosion core are extracted from space-resolved spectra and also evaluated using 1D spherical scaling. The trends are similar to the Ti number density spatial profiles. The areal densities extracted from data and 1D spherical scaling are very comparable in the outer spherical zones of the implosion core but significantly deviate in the innermost zone. We have observed that approximately 85% of the Ti atoms migrate into the hot core, while 15% of the atoms are still on the shell-fuel interface and contributing to the absorption. In addition, a method to extract the hot spot size based on the formation of the absorption feature in a sequence of annular spectra will be discussed. Results and trends are discussed as a function of target shell thickness and filling pressure, and laser pulse shape.

  18. Micro ring cavity resonator incorporating total internal reflection mirrors

    NASA Astrophysics Data System (ADS)

    Kim, Doo Gun; Choi, Woon Kyung; Choi, Young Wan; Yi, Jong Chang; Chung, Youngchul; Dagli, Nadir

    2007-02-01

    We investigate the properties of a multimode-interference (MMI) coupled micro ring cavity resonator with total-internal-reflection (TIR) mirrors and a semiconductor optical amplifier (SOA). The TIR mirrors were fabricated by the self-aligned process with a loss of 0.7 dB per mirror. The length and width of an MMI are 142 μm and 10 μm, respectively. The resulting free spectral range (FSR) of the resonator was approximately 1.698 nm near 1571 nm and the extinction ratio was about 17 dB. These devices might be useful as optical switching and add-drop filters in a photonic integrated circuit or as small and fast resonator devices.

  19. Design optimization of integrated BiDi triplexer optical filter based on planar lightwave circuit.

    PubMed

    Xu, Chenglin; Hong, Xiaobin; Huang, Wei-Ping

    2006-05-29

    Design optimization of a novel integrated bi-directional (BiDi) triplexer filter based on planar lightwave circuit (PLC) for fiber-to-the premise (FTTP) applications is described. A multi-mode interference (MMI) device is used to filter the up-stream 1310nm signal from the down-stream 1490nm and 1555nm signals. An array waveguide grating (AWG) device performs the dense WDM function by further separating the two down-stream signals. The MMI and AWG are built on the same substrate with monolithic integration. The design is validated by simulation, which shows excellent performance in terms of filter spectral characteristics (e.g., bandwidth, cross-talk, etc.) as well as insertion loss.

  20. Design optimization of integrated BiDi triplexer optical filter based on planar lightwave circuit

    NASA Astrophysics Data System (ADS)

    Xu, Chenglin; Hong, Xiaobin; Huang, Wei-Ping

    2006-05-01

    Design optimization of a novel integrated bi-directional (BiDi) triplexer filter based on planar lightwave circuit (PLC) for fiber-to-the premise (FTTP) applications is described. A multi-mode interference (MMI) device is used to filter the up-stream 1310nm signal from the down-stream 1490nm and 1555nm signals. An array waveguide grating (AWG) device performs the dense WDM function by further separating the two down-stream signals. The MMI and AWG are built on the same substrate with monolithic integration. The design is validated by simulation, which shows excellent performance in terms of filter spectral characteristics (e.g., bandwidth, cross-talk, etc.) as well as insertion loss.

  1. Synthesis of Hadamard transformers by use of multimode interference optical waveguides.

    PubMed

    Gupta, Atma Ram; Tsutsumi, Kiyoshi; Nakayama, Junichi

    2003-05-20

    We propose a synthesis method of optical Hadamard transformer using multimode interference (MMI) couplers. By using the signal transfer matrix of 2 x 2, 4 x 4, and 8 x 8 MMI couplers, we show that sum and difference units of input signals can be synthesized. An interchange unit of two signals can also be synthesized. One synthesis method of Hadamard transformers is a combination of only 2 x 2 units, and the other is a combination of N x N(N > or = 4) units as well as 2 x 2 units. The design examples of operation units are shown, and the size and the output power of Hadamard transformers are estimated.

  2. Medical treatment of hyperthyroidism: state of the art.

    PubMed

    Fumarola, A; Di Fiore, A; Dainelli, M; Grani, G; Calvanese, A

    2010-11-01

    Methimazole (MMI) and propylthiouracil (PTU) are the main antithyroid drugs used for hyperthyroidism. They inhibit the synthesis of thyroid hormone at various levels and are used as the primary treatment for hyperthyroidism or as a preparation before radioiodine therapy or thyroidectomy. MMI is the drug of choice because of its widespread availability, longer half-life and small number of severe side effects. Drugs of second choice are potassium perchlorate, beta blockers, iodine, lithium carbonate and glucocorticoids. Rituximab, a monoclonal antibody directed against human CD20, was recently proposed as a biological therapy for cases of Graves' disease unresponsive to traditional drugs. © J. A. Barth Verlag in Georg Thieme Verlag KG Stuttgart · New York.

  3. Transient polyuria related to central diabetes insipidus caused by lymphocytic infundibulo-neurohypophysitis in a patient treated for Graves' disease.

    PubMed

    Yamazaki, Masanori; Sato, Ai; Nishio, Shin-ichi; Uehara, Takeshi; Komatsu, Mitsuhisa

    2010-01-01

    A 45-year-old man was hospitalized because of weight loss, finger tremor, thirst, polydipsia and increased urinary frequency. He was diagnosed with Graves' disease (GD) and central diabetes insipidus (CDI). Magnetic resonance imaging revealed the enlarged posterior pituitary with thickened stalk. Histological examination obtained from biopsy of the pituitary revealed lymphocytic infundibulo-neurohypophysitis. He received treatment with thiamazole (MMI) for GD and desmopressin acetate (DDAVP) for CDI. However, DDAVP administration could be discontinued as GD was gradually improved. This course indicates that not only the recovered renal response to arginine-vasopressin but also the immunomodulative effects of MMI might attribute to the improvement of polyuria.

  4. Advances in Machine Technology.

    PubMed

    Clark, William R; Villa, Gianluca; Neri, Mauro; Ronco, Claudio

    2018-01-01

    Continuous renal replacement therapy (CRRT) machines have evolved into devices specifically designed for critically ill over the past 40 years. In this chapter, a brief history of this evolution is first provided, with emphasis on the manner in which changes have been made to address the specific needs of the critically ill patient with acute kidney injury. Subsequently, specific examples of technology developments for CRRT machines are discussed, including the user interface, pumps, pressure monitoring, safety features, and anticoagulation capabilities. © 2018 S. Karger AG, Basel.

  5. Real English: A Translator to Enable Natural Language Man-Machine Conversation.

    ERIC Educational Resources Information Center

    Gautin, Harvey

    This dissertation presents a pragmatic interpreter/translator called Real English to serve as a natural language man-machine communication interface in a multi-mode on-line information retrieval system. This multi-mode feature affords the user a library-like searching tool by giving him access to a dictionary, lexicon, thesaurus, synonym table,…

  6. Spatial Brain Control Interface using Optical and Electrophysiological Measures

    DTIC Science & Technology

    2013-08-27

    appropriate for implementing a reliable brain-computer interface ( BCI ). The LSVM method 1. REPORT DATE (DD-MM-YYYY) 4. TITLE AND SUBTITLE 27-08-2013 13...Machine (LSVM) was the most appropriate for implementing a reliable brain-computer interface ( BCI ). The LSVM method was applied to the imaging data...local field potentials proved to be fast and strongly tuned for the spatial parameters of the task. Thus, a reliable BCI that can predict upcoming

  7. State transition storyboards: A tool for designing the Goldstone solar system radar data acquisition system user interface software

    NASA Technical Reports Server (NTRS)

    Howard, S. D.

    1987-01-01

    Effective user interface design in software systems is a complex task that takes place without adequate modeling tools. By combining state transition diagrams and the storyboard technique of filmmakers, State Transition Storyboards were developed to provide a detailed modeling technique for the Goldstone Solar System Radar Data Acquisition System human-machine interface. Illustrations are included with a description of the modeling technique.

  8. Intelligent Adaptive Systems: Literature Research of Design Guidance for Intelligent Adaptive Automation and Interfaces

    DTIC Science & Technology

    2007-09-01

    behaviour based on past experience of interacting with the operator), and mobile (i.e., can move themselves from one machine to another). Edwards argues that...Sofge, D., Bugajska, M., Adams, W., Perzanowski, D., and Schultz, A. (2003). Agent-based Multimodal Interface for Dynamically Autonomous Mobile Robots...based architecture can provide a natural and scalable approach to implementing a multimodal interface to control mobile robots through dynamic

  9. myChEMBL: a virtual machine implementation of open data and cheminformatics tools.

    PubMed

    Ochoa, Rodrigo; Davies, Mark; Papadatos, George; Atkinson, Francis; Overington, John P

    2014-01-15

    myChEMBL is a completely open platform, which combines public domain bioactivity data with open source database and cheminformatics technologies. myChEMBL consists of a Linux (Ubuntu) Virtual Machine featuring a PostgreSQL schema with the latest version of the ChEMBL database, as well as the latest RDKit cheminformatics libraries. In addition, a self-contained web interface is available, which can be modified and improved according to user specifications. The VM is available at: ftp://ftp.ebi.ac.uk/pub/databases/chembl/VM/myChEMBL/current. The web interface and web services code is available at: https://github.com/rochoa85/myChEMBL.

  10. Tactual interfaces: The human perceiver

    NASA Technical Reports Server (NTRS)

    Srinivasan, M. A.

    1991-01-01

    Increasingly complex human-machine interactions, such as in teleoperation or in virtual environments, have necessitated the optimal use of the human tactual channel for information transfer. This need leads to a demand for a basic understanding of how the human tactual system works, so that the tactual interface between the human and the machine can receive the command signals from the human, as well as display the information to the human, in a manner that appears natural to the human. The tactual information consists of two components: (1) contact information which specifies the nature of direct contact with the object; and (2) kinesthetic information which refers to the position and motion of the limbs. This paper is mostly concerned with contact information.

  11. Analysis of a display and control system man-machine interface concept. Volume 1: Final technical report

    NASA Technical Reports Server (NTRS)

    Karl, D. R.

    1972-01-01

    An evaluation was made of the feasibility of utilizing a simplified man machine interface concept to manage and control a complex space system involving multiple redundant computers that control multiple redundant subsystems. The concept involves the use of a CRT for display and a simple keyboard for control, with a tree-type control logic for accessing and controlling mission, systems, and subsystem elements. The concept was evaluated in terms of the Phase B space shuttle orbiter, to utilize the wide scope of data management and subsystem control inherent in the central data management subsystem provided by the Phase B design philosophy. Results of these investigations are reported in four volumes.

  12. New generation emerging technologies for neurorehabilitation and motor assistance.

    PubMed

    Frisoli, Antonio; Solazzi, Massimiliano; Loconsole, Claudio; Barsotti, Michele

    2016-12-01

    This paper illustrates the application of emerging technologies and human-machine interfaces to the neurorehabilitation and motor assistance fields. The contribution focuses on wearable technologies and in particular on robotic exoskeleton as tools for increasing freedom to move and performing Activities of Daily Living (ADLs). This would result in a deep improvement in quality of life, also in terms of improved function of internal organs and general health status. Furthermore, the integration of these robotic systems with advanced bio-signal driven human-machine interface can increase the degree of participation of patient in robotic training allowing to recognize user's intention and assisting the patient in rehabilitation tasks, thus representing a fundamental aspect to elicit motor learning.

  13. Developments in brain-machine interfaces from the perspective of robotics.

    PubMed

    Kim, Hyun K; Park, Shinsuk; Srinivasan, Mandayam A

    2009-04-01

    Many patients suffer from the loss of motor skills, resulting from traumatic brain and spinal cord injuries, stroke, and many other disabling conditions. Thanks to technological advances in measuring and decoding the electrical activity of cortical neurons, brain-machine interfaces (BMI) have become a promising technology that can aid paralyzed individuals. In recent studies on BMI, robotic manipulators have demonstrated their potential as neuroprostheses. Restoring motor skills through robot manipulators controlled by brain signals may improve the quality of life of people with disability. This article reviews current robotic technologies that are relevant to BMI and suggests strategies that could improve the effectiveness of a brain-operated neuroprosthesis through robotics.

  14. Early return to work in workers' compensation patients after arthroscopic full-thickness rotator cuff repair.

    PubMed

    Bhatia, Sanjeev; Piasecki, Dana P; Nho, Shane Jay; Romeo, Anthony A; Cole, Brian J; Nicholson, Gregory P; Boniquit, Nicole; Verma, Nikhil N

    2010-08-01

    The purpose of this study was to investigate the ability of patients to return to their preoperative work level and to identify functional prognostic factors in a group of Workers' Compensation (WC) patients after arthroscopic repair of full-thickness rotator cuff tears at a minimum follow-up of 1 year. Seventy-eight consecutive WC patients underwent arthroscopic rotator cuff repair (ARCR) and were retrospectively reviewed. Potential predictors of occupational outcomes were recorded. The primary outcomes included work level at the time of discharge, time to maximum medical improvement (MMI), and failures requiring revision rotator cuff repair. Secondary outcomes including physical examination and subjective scoring scales were also recorded. Overall, 88.5% of patients (n = 69) returned to their preoperative level of work at a mean time to MMI of 7.6 +/- 2.6 months. Of the WC patients, 55 (70.5%) were followed up for purposes of assessing shoulder function, with a mean follow-up of 33.6 +/- 13.9 months. The mean American Shoulder and Elbow Surgeons score at this time was 82.3 +/- 20.9, and the mean score on a visual analog scale was 1.7 +/- 2.3. An association was found between patients who underwent ARCR with open biceps tenodesis and delay in MMI (P = .01). WC patients undergoing ARCR may expect a high likelihood of return to full duty at a mean time to MMI of 7.6 months. At the time of follow-up, patients reported good outcomes using validated scoring scales, but subjective outcomes remained inferior to non-WC patients based on historical controls. Alcohol use was the only prognostic factor to show a significant association with return to restricted-duty employment and repair failure. Level IV, therapeutic case series. 2010 Arthroscopy Association of North America. Published by Elsevier Inc. All rights reserved.

  15. Anti-glutamic acid decarboxylase antibody in Graves' disease is a possible indicator for the unlikelihood of going into remission with antithyroid agents.

    PubMed

    Yoshihara, Ai; Isozaki, Osamu; Okubo, Yumiko; Takano, Kazue

    2009-01-01

    The prevalence and titer of glutamic acid decarboxylase antibody (GADAb) in type 1 diabetes mellitus (T1DM) has been reported to be higher in patients with autoimmune thyroid diseases (AITD) than those without them. However, we have no data about the influence of GADAb on AITD. We therefore studied the clinical characteristics of Graves' disease (GD) with GADAb in order to clarify the influence of GADAb on GD. Twelve GD patients with GADAb were enrolled and were compared to 40 GD patients without DM. The male to female ratio and age of onset of GD showed no statistical difference. The titer of TSH receptor antibody (TRAb) at the onset of GD was similar in both groups. Initial treatment with methimazole (MMI) was started in all patients with GADAb but radioactive iodine (RI) therapy was carried out in five patients because of adverse effects of MMI or poor control of hyperthyroidism. The initial titer of TRAb was significantly lower in patients treated with MMI alone compared to that in RI treated patients but none of the patients treated with MMI alone went into remission after more than 3-years of follow up. We also compared these GADAb-positive patients with 14 patients with diabetes mellitus who had matched clinical features. The number of diabetic patients who remained in possible remission was significantly higher than that of GADAb-positive patients (5 in 14 vs 0 in 12). Moreover, the rate of remission in the diabetic patients was no different from that of 21 control patients without diabetes followed for more than 7 years (5 in 14 vs 7 in 21). These data suggested that GADAb-positive patients are unlikely to go into remission with antithyroid agents. Therefore, definitive therapies might be preferable for the initial treatment of GADAb-positive patients.

  16. Antithyroid Drugs and Congenital Malformations: A Nationwide Korean Cohort Study.

    PubMed

    Seo, Gi Hyeon; Kim, Tae Hyuk; Chung, Jae Hoon

    2018-03-20

    Untreated or insufficiently treated Graves disease in pregnancy may pose risks to both mother and fetus. Antithyroid drugs (ATDs) are the treatment mainstay, but the potential teratogenic effect of these drugs has prompted clinicians to question the safe management of this vulnerable population. To examine the association between maternal prescriptions for ATDs and congenital malformations in live births. Nationwide cohort study. Korean National Health Insurance database. A cohort of 2 886 970 completed pregnancies linked to live-born infants in 2 210 253 women between 2008 and 2014. Maternal prescriptions for ATDs in the first trimester. The risk for overall and organ-specific congenital malformations in offspring, with logistic regression models used to control for potential confounders. 12 891 pregnancies (0.45%) were exposed to ATDs during the first trimester. The prevalence of malformations in exposed offspring was 7.27%, compared with 5.94% in offspring of women who were not prescribed ATDs during pregnancy (P < 0.001) (adjusted odds ratio, 1.19 [95% CI, 1.12 to 1.28]). Absolute increases in the prevalence of congenital malformations per 1000 live births were 8.81 cases (CI, 3.92 to 13.70 cases) for propylthiouracil alone, 17.05 cases (CI, 1.94 to 32.15 cases) for methimazole (MMI) alone, and 16.53 cases (CI, 4.73 to 28.32 cases) for propylthiouracil and MMI, compared with pregnancies without ATD prescriptions. In the MMI group, a high cumulative dose (>495 mg) during the first trimester was associated with an increased risk for malformations compared with a low dose (1 to 126 mg) (adjusted odds ratio, 1.87 [CI, 1.06 to 3.30]). The study used a prescription claims database to assess ATD exposure. Exposure to ATDs during the first trimester was associated with increased risk for congenital malformations, particularly for pregnancies in which women received prescriptions for MMI or both ATDs. None.

  17. Mechanical Structural Design of a MEMS-Based Piezoresistive Accelerometer for Head Injuries Monitoring: A Computational Analysis by Increments of the Sensor Mass Moment of Inertia †

    PubMed Central

    Messina, Marco; Njuguna, James; Palas, Chrysovalantis

    2018-01-01

    This work focuses on the proof-mass mechanical structural design improvement of a tri-axial piezoresistive accelerometer specifically designed for head injuries monitoring where medium-G impacts are common; for example, in sports such as racing cars or American Football. The device requires the highest sensitivity achievable with a single proof-mass approach, and a very low error (<1%) as the accuracy for these types of applications is paramount. The optimization method differs from previous work as it is based on the progressive increment of the sensor proof-mass mass moment of inertia (MMI) in all three axes. Three different designs are presented in this study, where at each step of design evolution, the MMI of the sensor proof-mass gradually increases in all axes. The work numerically demonstrates that an increment of MMI determines an increment of device sensitivity with a simultaneous reduction of cross-axis sensitivity in the particular axis under study. This is due to the linkage between the external applied stress and the distribution of mass (of the proof-mass), and therefore of its mass moment of inertia. Progressively concentrating the mass on the axes where the piezoresistors are located (i.e., x- and y-axis) by increasing the MMI in the x- and y-axis, will undoubtedly increase the longitudinal stresses applied in that areas for a given external acceleration, therefore increasing the piezoresistors fractional resistance change and eventually positively affecting the sensor sensitivity. The final device shows a sensitivity increase of about 80% in the z-axis and a reduction of cross-axis sensitivity of 18% respect to state-of-art sensors available in the literature from a previous work of the authors. Sensor design, modelling, and optimization are presented, concluding the work with results, discussion, and conclusion. PMID:29351221

  18. SARCOSPA - Sarcopenia in spondyloarthritis patients.

    PubMed

    Aguiar, R; Sequeira, J; Meirinhos, T; Ambrósio, C; Barcelos, A

    2014-01-01

    The loss of muscle mass (MM) is a serious problem which has been demonstrated in patients with rheumatoid arthritis. There are few studies about the loss of MM in patients with spondyloarthritis (Spa). To assess muscle mass index (MMI) in a cohort of patients with Spa and compare it with a control group of healthy individuals; to verify if a higher risk of sarcopenia is related with disease activity, functional impairment, duration of the illness and radiological damage. Case control study. Muscle mass index (MMI) was determined, from the value of MM, using Lee's equation, in a cohort of patients with spondyloarthritis and in a control group. Bath Ankylosing Spondylitis Disease Activity and Function Indexes (BASDAI and BASFI), Ankylosing Spondylitis Quality of Life (ASQoL) and Modified Stoke Ankylosing Spondylitis Spinal Score (mSASSS) were assessed in a cohort of patients with axial Spa, as well as Health Assessment Questionnaire (HAQ) and Disease Activity Score 28 (DAS28) in patients with peripheral disease. Data were treated using SPSS version 17.0. Values of p<0,05 were considered with statistical significance. 60 patients were enrolled; 48.2% were males, mean age 45.5±13.4 years, mean disease duration 10.9±11.6 years; 36 had ankylosing spondylitis and 24 had psoriatic arthritis. 62% of patients had sarcopenia and there was a significant difference in mean MMI between patients and controls (7.65±0.98 vs 8.25±0.92; p=0.001, OR =5.23. In male patients, there was a statistically significant moderate negative correlation between MMI and BASDAI and BASFI (p=-0.536 and p=-0.445). No other significant correlations were identified. Our study supports the hypothesis of a greater prevalence of sarcopenia in patients with Spa compared to healthy controls. Some limitations included the sample size, potential confounding factor such the bias of measurement and the use of a non-validated equation to Portuguese population to calculate MM.

  19. Calibrated thermal microscopy of the tool-chip interface in machining

    NASA Astrophysics Data System (ADS)

    Yoon, Howard W.; Davies, Matthew A.; Burns, Timothy J.; Kennedy, M. D.

    2000-03-01

    A critical parameter in predicting tool wear during machining and in accurate computer simulations of machining is the spatially-resolved temperature at the tool-chip interface. We describe the development and the calibration of a nearly diffraction-limited thermal-imaging microscope to measure the spatially-resolved temperatures during the machining of an AISI 1045 steel with a tungsten-carbide tool bit. The microscope has a target area of 0.5 mm X 0.5 mm square region with a < 5 micrometers spatial resolution and is based on a commercial InSb 128 X 128 focal plane array with an all reflective microscope objective. The minimum frame image acquisition time is < 1 ms. The microscope is calibrated using a standard blackbody source from the radiance temperature calibration laboratory at the National Institute of Standards and Technology, and the emissivity of the machined material is deduced from the infrared reflectivity measurements. The steady-state thermal images from the machining of 1045 steel are compared to previous determinations of tool temperatures from micro-hardness measurements and are found to be in agreement with those studies. The measured average chip temperatures are also in agreement with the temperature rise estimated from energy balance considerations. From these calculations and the agreement between the experimental and the calculated determinations of the emissivity of the 1045 steel, the standard uncertainty of the temperature measurements is estimated to be about 45 degree(s)C at 900 degree(s)C.

  20. Optofluidic devices for biomolecule sensing and multiplexing

    NASA Astrophysics Data System (ADS)

    Ozcelik, Damla

    Optofluidics which integrates photonics and microfluidics, has led to highly compact, sensitive and adaptable biomedical sensors. Optofluidic biosensors based on liquid-core anti-resonant reflecting optical waveguides (LC-ARROWs), have proven to be a highly sensitive, portable, and reconfigurable platform for fluorescence spectroscopy and detection of single biomolecules such as proteins, nucleic acids, and virus particles. However, continued improvements in sensitivity remain a major goal as we approach the ultimate limit of detecting individual bio-particles labeled by single or few fluorophores. Additionally, the ability to simultaneously detect and identify multiple biological particles or biomarkers is one of the key requirements for molecular diagnostic tests. The compactness and adaptability of these platforms can further be advanced by introducing tunability, integrating off-chip components, designing reconfigurable and customizable devices, which makes these platforms very good candidates for many different applications. The goal of this thesis was to introduce new elements in these LC-ARROW optofluidics platforms that provide major enhancements in their functionality, making them more sensitive, compact, customizable and multiplexed. First, a novel integrated tunable spectral filter that achieves effective elimination of background noise on the ARROW platform was demonstrated. A unique dual liquid-core design enabled the independent multi-wavelength tuning of the spectral filter by adjusting the refractive index and chemical properties of the liquid. In order to enhance the detection sensitivity of the platform, Y-splitter waveguides were integrated to create multiple excitation spots for each target molecule. A powerful signal processing algorithm was used to analyze the data to improve the signal-to-noise ratio (SNR) of the collected data. Next, the design, optimization and characterization of the Y-splitter waveguides are presented; and single influenza virus detection with an improved SNR was demonstrated using this platform. Finally, multiplexing capacity is introduced to the ARROW detection platform by integrating multi-mode interference (MMI) waveguides. MMI waveguides create wavelength dependent multiple excitation spots at the excitation region, allowing the spectral multiplexed detection of multiple different target molecules based on the excitation pattern, without the need for additional spectral filters. Successful spectral multiplexed detection of three different types of influenza viruses is achieved by using separate wavelengths and combination of wavelengths. This multiplexing capacity is further enhanced by taking advantage of the spatial properties of the MMI pattern, designing triple liquid-core waveguides that intersect the MMI waveguide in different locations. Furthermore, the spectral and spatial multiplexing capacities are combined in these triple liquid-core MMI platforms, allowing these devices to distinguish multiple different targets and samples simultaneously.

  1. Slow Long-Term Erosion Rates of Banks Peninsula, New Zealand

    NASA Astrophysics Data System (ADS)

    Dudunake, T.; Nichols, K. K.; Pugsley, E.; Nelson, S.; Colton, J.

    2017-12-01

    Banks Peninsula, located south of Christchurch, New Zealand, is composed of a multi-aged complex of volcanic centers. The oldest, Lyttelton Volcano is 12 to 10 Ma, and 350 km3. The largest volcano, Akaroa Volcano, is 9 to 8 Ma and 1200 km3. Both of these volcanoes have large embayments (Lyttelton Harbour and Akaroa Harbour) that connect the central volcano (the location of the former volcanic summits) to the ocean. The other eruptive centers, Mt. Herbert ( 9.5 to 8 Ma) and Diamond Harbor (7 to 5.8 Ma), have not eroded to sea level. We used inferred original surfaces and present day topography to calculate the volume of rock eroded from river valleys draining the flanks of Lyttelton (n=11) and Akaroa (n=26) volcanoes and from the large embayments that penetrate the eroding Lyttelton (n=8) and Akaroa (n=25) volcanoes. We used the youngest age of the eruptions as the start of erosion (Lyttelton = 10 Ma and Akaroa = 8 Ma) to determine erosion rates. Preliminary data suggest average erosion rates of 8.2 ± 2.4 m/My (averaged over 10 Ma) on the flanks of Lyttelton Volcano and 12 ± 5.1 m/My (averaged over 8 Ma) on the flanks of Akaroa Volcano. Dating control and formation processes of Lyttelton Harbour and Akaroa Harbour are poorly constrained. The youngest lava flows, Diamond Harbor, are 5.7 Ma and flow into the Lyttelton Harbour embayment. Using endmembers of embayment age for Lyttelton Harbour (10 Ma to 5.7 Ma) the erosion rates range between 18 ± 5.8 m/My and 31 ± 10 m/My. Similarly, the hillslopes of Akaroa Harbour have slow erosion rates (based on endmember ages of 8 Ma and 5.7 Ma) and range between 22 ± 18 and 31 ± 25 m/My. Even the fastest erosion rates on Banks Peninsula are an order of magnitude slower than the erosion rates of other basalt volcanoes in the world's oceans. Using a similar methodology, Tahiti is eroding between 1200 and 2700 m/Ma (Hildenbrand et al., 2008). Other erosion rates, based on sediment yields and water chemistry for La Reunion (400 to 3000 m/Ma; Louvat and Allegre, 1997), Guadeloupe (400 to 1700 m/Ma; Ricci et al., 2014), and Martinique (800 m/Ma; Germa et al., 2010) are also significantly faster than erosion rates of Banks Peninsula.

  2. Real-time implementation of electromyogram pattern recognition as a control command of man-machine interface.

    PubMed

    Chang, G C; Kang, W J; Luh, J J; Cheng, C K; Lai, J S; Chen, J J; Kuo, T S

    1996-10-01

    The purpose of this study was to develop a real-time electromyogram (EMG) discrimination system to provide control commands for man-machine interface applications. A host computer with a plug-in data acquisition and processing board containing a TMS320 C31 floating-point digital signal processor was used to attain real-time EMG classification. Two-channel EMG signals were collected by two pairs of surface electrodes located bilaterally between the sternocleidomastoid and the upper trapezius. Five motions of the neck and shoulders were discriminated for each subject. The zero-crossing rate was employed to detect the onset of muscle contraction. The cepstral coefficients, derived from autoregressive coefficients and estimated by a recursive least square algorithm, were used as the recognition features. These features were then discriminated using a modified maximum likelihood distance classifier. The total response time of this EMG discrimination system was achieved about within 0.17 s. Four able bodied and two C5/6 quadriplegic subjects took part in the experiment, and achieved 95% mean recognition rate in discrimination between the five specific motions. The response time and the reliability of recognition indicate that this system has the potential to discriminate body motions for man-machine interface applications.

  3. Concurrent Image Processing Executive (CIPE). Volume 1: Design overview

    NASA Technical Reports Server (NTRS)

    Lee, Meemong; Groom, Steven L.; Mazer, Alan S.; Williams, Winifred I.

    1990-01-01

    The design and implementation of a Concurrent Image Processing Executive (CIPE), which is intended to become the support system software for a prototype high performance science analysis workstation are described. The target machine for this software is a JPL/Caltech Mark 3fp Hypercube hosted by either a MASSCOMP 5600 or a Sun-3, Sun-4 workstation; however, the design will accommodate other concurrent machines of similar architecture, i.e., local memory, multiple-instruction-multiple-data (MIMD) machines. The CIPE system provides both a multimode user interface and an applications programmer interface, and has been designed around four loosely coupled modules: user interface, host-resident executive, hypercube-resident executive, and application functions. The loose coupling between modules allows modification of a particular module without significantly affecting the other modules in the system. In order to enhance hypercube memory utilization and to allow expansion of image processing capabilities, a specialized program management method, incremental loading, was devised. To minimize data transfer between host and hypercube, a data management method which distributes, redistributes, and tracks data set information was implemented. The data management also allows data sharing among application programs. The CIPE software architecture provides a flexible environment for scientific analysis of complex remote sensing image data, such as planetary data and imaging spectrometry, utilizing state-of-the-art concurrent computation capabilities.

  4. Mechanically Compliant Electronic Materials for Wearable Photovoltaics and Human-Machine Interfaces

    NASA Astrophysics Data System (ADS)

    O'Connor, Timothy Francis, III

    Applications of stretchable electronic materials for human-machine interfaces are described herein. Intrinsically stretchable organic conjugated polymers and stretchable electronic composites were used to develop stretchable organic photovoltaics (OPVs), mechanically robust wearable OPVs, and human-machine interfaces for gesture recognition, American Sign Language Translation, haptic control of robots, and touch emulation for virtual reality, augmented reality, and the transmission of touch. The stretchable and wearable OPVs comprise active layers of poly-3-alkylthiophene:phenyl-C61-butyric acid methyl ester (P3AT:PCBM) and transparent conductive electrodes of poly(3,4-ethylenedioxythiophene)-poly(styrenesulfonate) (PEDOT:PSS) and devices could only be fabricated through a deep understanding of the connection between molecular structure and the co-engineering of electronic performance with mechanical resilience. The talk concludes with the use of composite piezoresistive sensors two smart glove prototypes. The first integrates stretchable strain sensors comprising a carbon-elastomer composite, a wearable microcontroller, low energy Bluetooth, and a 6-axis accelerometer/gyroscope to construct a fully functional gesture recognition glove capable of wirelessly translating American Sign Language to text on a cell phone screen. The second creates a system for the haptic control of a 3D printed robot arm, as well as the transmission of touch and temperature information.

  5. Soft brain-machine interfaces for assistive robotics: A novel control approach.

    PubMed

    Schiatti, Lucia; Tessadori, Jacopo; Barresi, Giacinto; Mattos, Leonardo S; Ajoudani, Arash

    2017-07-01

    Robotic systems offer the possibility of improving the life quality of people with severe motor disabilities, enhancing the individual's degree of independence and interaction with the external environment. In this direction, the operator's residual functions must be exploited for the control of the robot movements and the underlying dynamic interaction through intuitive and effective human-robot interfaces. Towards this end, this work aims at exploring the potential of a novel Soft Brain-Machine Interface (BMI), suitable for dynamic execution of remote manipulation tasks for a wide range of patients. The interface is composed of an eye-tracking system, for an intuitive and reliable control of a robotic arm system's trajectories, and a Brain-Computer Interface (BCI) unit, for the control of the robot Cartesian stiffness, which determines the interaction forces between the robot and environment. The latter control is achieved by estimating in real-time a unidimensional index from user's electroencephalographic (EEG) signals, which provides the probability of a neutral or active state. This estimated state is then translated into a stiffness value for the robotic arm, allowing a reliable modulation of the robot's impedance. A preliminary evaluation of this hybrid interface concept provided evidence on the effective execution of tasks with dynamic uncertainties, demonstrating the great potential of this control method in BMI applications for self-service and clinical care.

  6. Toward a mathematical formalism of performance, task difficulty, and activation

    NASA Technical Reports Server (NTRS)

    Samaras, George M.

    1988-01-01

    The rudiments of a mathematical formalism for handling operational, physiological, and psychological concepts are developed for use by the man-machine system design engineer. The formalism provides a framework for developing a structured, systematic approach to the interface design problem, using existing mathematical tools, and simplifying the problem of telling a machine how to measure and use performance.

  7. Optical HMI with biomechanical energy harvesters integrated in textile supports

    NASA Astrophysics Data System (ADS)

    De Pasquale, G.; Kim, SG; De Pasquale, D.

    2015-12-01

    This paper reports the design, prototyping and experimental validation of a human-machine interface (HMI), named GoldFinger, integrated into a glove with energy harvesting from fingers motion. The device is addressed to medical applications, design tools, virtual reality field and to industrial applications where the interaction with machines is restricted by safety procedures. The HMI prototype includes four piezoelectric transducers applied to the fingers backside at PIP (proximal inter-phalangeal) joints, electric wires embedded in the fabric connecting the transducers, aluminum case for the electronics, wearable switch made with conductive fabrics to turn the communication channel on and off, and a LED. The electronic circuit used to manage the power and to control the light emitter includes a diodes bridge, leveling capacitors, storage battery and switch made by conductive fabric. The communication with the machine is managed by dedicated software, which includes the user interface, the optical tracking, and the continuous updating of the machine microcontroller. The energetic benefit of energy harvester on the battery lifetime is inversely proportional to the activation time of the optical emitter. In most applications, the optical port is active for 1 to 5% of the time, corresponding to battery lifetime increasing between about 14% and 70%.

  8. Visualization tool for human-machine interface designers

    NASA Astrophysics Data System (ADS)

    Prevost, Michael P.; Banda, Carolyn P.

    1991-06-01

    As modern human-machine systems continue to grow in capabilities and complexity, system operators are faced with integrating and managing increased quantities of information. Since many information components are highly related to each other, optimizing the spatial and temporal aspects of presenting information to the operator has become a formidable task for the human-machine interface (HMI) designer. The authors describe a tool in an early stage of development, the Information Source Layout Editor (ISLE). This tool is to be used for information presentation design and analysis; it uses human factors guidelines to assist the HMI designer in the spatial layout of the information required by machine operators to perform their tasks effectively. These human factors guidelines address such areas as the functional and physical relatedness of information sources. By representing these relationships with metaphors such as spring tension, attractors, and repellers, the tool can help designers visualize the complex constraint space and interacting effects of moving displays to various alternate locations. The tool contains techniques for visualizing the relative 'goodness' of a configuration, as well as mechanisms such as optimization vectors to provide guidance toward a more optimal design. Also available is a rule-based design checker to determine compliance with selected human factors guidelines.

  9. A machine learning system to improve heart failure patient assistance.

    PubMed

    Guidi, Gabriele; Pettenati, Maria Chiara; Melillo, Paolo; Iadanza, Ernesto

    2014-11-01

    In this paper, we present a clinical decision support system (CDSS) for the analysis of heart failure (HF) patients, providing various outputs such as an HF severity evaluation, HF-type prediction, as well as a management interface that compares the different patients' follow-ups. The whole system is composed of a part of intelligent core and of an HF special-purpose management tool also providing the function to act as interface for the artificial intelligence training and use. To implement the smart intelligent functions, we adopted a machine learning approach. In this paper, we compare the performance of a neural network (NN), a support vector machine, a system with fuzzy rules genetically produced, and a classification and regression tree and its direct evolution, which is the random forest, in analyzing our database. Best performances in both HF severity evaluation and HF-type prediction functions are obtained by using the random forest algorithm. The management tool allows the cardiologist to populate a "supervised database" suitable for machine learning during his or her regular outpatient consultations. The idea comes from the fact that in literature there are a few databases of this type, and they are not scalable to our case.

  10. The Strength of the Metal. Aluminum Oxide Interface

    NASA Technical Reports Server (NTRS)

    Pepper, S. V.

    1984-01-01

    The strength of the interface between metals and aluminum oxide is an important factor in the successful operation of devices found throughout modern technology. One finds the interface in machine tools, jet engines, and microelectronic integrated circuits. The strength of the interface, however, should be strong or weak depending on the application. The diverse technological demands have led to some general ideas concerning the origin of the interfacial strength, and have stimulated fundamental research on the problem. Present status of our understanding of the source of the strength of the metal - aluminum oxide interface in terms of interatomic bonds are reviewed. Some future directions for research are suggested.

  11. Simulation of the «COSMONAUT-ROBOT» System Interaction on the Lunar Surface Based on Methods of Machine Vision and Computer Graphics

    NASA Astrophysics Data System (ADS)

    Kryuchkov, B. I.; Usov, V. M.; Chertopolokhov, V. A.; Ronzhin, A. L.; Karpov, A. A.

    2017-05-01

    Extravehicular activity (EVA) on the lunar surface, necessary for the future exploration of the Moon, involves extensive use of robots. One of the factors of safe EVA is a proper interaction between cosmonauts and robots in extreme environments. This requires a simple and natural man-machine interface, e.g. multimodal contactless interface based on recognition of gestures and cosmonaut's poses. When travelling in the "Follow Me" mode (master/slave), a robot uses onboard tools for tracking cosmonaut's position and movements, and on the basis of these data builds its itinerary. The interaction in the system "cosmonaut-robot" on the lunar surface is significantly different from that on the Earth surface. For example, a man, dressed in a space suit, has limited fine motor skills. In addition, EVA is quite tiring for the cosmonauts, and a tired human being less accurately performs movements and often makes mistakes. All this leads to new requirements for the convenient use of the man-machine interface designed for EVA. To improve the reliability and stability of human-robot communication it is necessary to provide options for duplicating commands at the task stages and gesture recognition. New tools and techniques for space missions must be examined at the first stage of works in laboratory conditions, and then in field tests (proof tests at the site of application). The article analyzes the methods of detection and tracking of movements and gesture recognition of the cosmonaut during EVA, which can be used for the design of human-machine interface. A scenario for testing these methods by constructing a virtual environment simulating EVA on the lunar surface is proposed. Simulation involves environment visualization and modeling of the use of the "vision" of the robot to track a moving cosmonaut dressed in a spacesuit.

  12. DNA Bipedal Motor Achieves a Large Number of Steps Due to Operation Using Microfluidics-Based Interface.

    PubMed

    Tomov, Toma E; Tsukanov, Roman; Glick, Yair; Berger, Yaron; Liber, Miran; Avrahami, Dorit; Gerber, Doron; Nir, Eyal

    2017-04-25

    Realization of bioinspired molecular machines that can perform many and diverse operations in response to external chemical commands is a major goal in nanotechnology, but current molecular machines respond to only a few sequential commands. Lack of effective methods for introduction and removal of command compounds and low efficiencies of the reactions involved are major reasons for the limited performance. We introduce here a user interface based on a microfluidics device and single-molecule fluorescence spectroscopy that allows efficient introduction and removal of chemical commands and enables detailed study of the reaction mechanisms involved in the operation of synthetic molecular machines. The microfluidics provided 64 consecutive DNA strand commands to a DNA-based motor system immobilized inside the microfluidics, driving a bipedal walker to perform 32 steps on a DNA origami track. The microfluidics enabled removal of redundant strands, resulting in a 6-fold increase in processivity relative to an identical motor operated without strand removal and significantly more operations than previously reported for user-controlled DNA nanomachines. In the motor operated without strand removal, redundant strands interfere with motor operation and reduce its performance. The microfluidics also enabled computer control of motor direction and speed. Furthermore, analysis of the reaction kinetics and motor performance in the absence of redundant strands, made possible by the microfluidics, enabled accurate modeling of the walker processivity. This enabled identification of dynamic boundaries and provided an explanation, based on the "trap state" mechanism, for why the motor did not perform an even larger number of steps. This understanding is very important for the development of future motors with significantly improved performance. Our universal interface enables two-way communication between user and molecular machine and, relying on concepts similar to that of solid-phase synthesis, removes limitations on the number of external stimuli. This interface, therefore, is an important step toward realization of reliable, processive, reproducible, and useful externally controlled DNA nanomachines.

  13. Silicon-on-insulator multimode-interference waveguide-based arrayed optical tweezers (SMART) for two-dimensional microparticle trapping and manipulation.

    PubMed

    Lei, Ting; Poon, Andrew W

    2013-01-28

    We demonstrate two-dimensional optical trapping and manipulation of 1 μm and 2.2 μm polystyrene particles in an 18 μm-thick fluidic cell at a wavelength of 1565 nm using the recently proposed Silicon-on-insulator Multimode-interference (MMI) waveguide-based ARrayed optical Tweezers (SMART) technique. The key component is a 100 μm square-core silicon waveguide with mm length. By tuning the fiber-coupling position at the MMI waveguide input facet, we demonstrate various patterns of arrayed optical tweezers that enable optical trapping and manipulation of particles. We numerically simulate the physical mechanisms involved in the arrayed trap, including the optical force, the heat transfer and the thermal-induced microfluidic flow.

  14. Realization of an ultra-compact polarization beam splitter using asymmetric MMI based on silicon nitride / silicon-on-insulator platform.

    PubMed

    Sun, Xiao; Aitchison, J Stewart; Mojahedi, Mo

    2017-04-03

    We have experimentally demonstrated a compact polarization beam splitter (PBS) based on the silicon nitride/silicon-on-insulator platform using the recently proposed augmented-low-index-guiding (ALIG) waveguide structure. The two orthogonal polarizations are split in an asymmetric multimode interference (MMI) section, which was 1.6 μm wide and 4.8 μm long. The device works well over the entire C-band wavelength range and has a measured low insertion loss of less than 1 dB. The polarization extinction ratio at the Bar Port is approximately 17 dB and at the Cross Port is approximately 25 dB. The design of the device is robust and has a good fabrication tolerance.

  15. Multimodal transmission property in a liquid-filled photonic crystal fiber

    NASA Astrophysics Data System (ADS)

    Lin, Wei; Miao, Yinping; Song, Binbin; Zhang, Hao; Liu, Bo; Liu, Yange; Yan, Donglin

    2015-02-01

    The multimode interference (MMI) effect in a liquid-filled photonic crystal fiber (PCF) has been experimentally demonstrated by fully infiltrating the air-hole cladding of a solid-core PCF with the refractive index (RI) matching liquid whose RI is close to the silica background. Due to the weak mode confinement capability of the cladding region, several high-order modes are excited to establish the multimode interference effect. The multimode interferometer shows a good temperature tunability of 12.30 nm/K, which makes it a good candidate for a highly tunable optical filtering as well as temperature sensing applications. Furthermore, this MMI effect would have great promise in various applications such as highly sensitive multi-parameter sensing, tunable optically filtering, and surface-enhanced Raman scattering.

  16. 3D Mueller-matrix mapping of biological optically anisotropic networks

    NASA Astrophysics Data System (ADS)

    Ushenko, O. G.; Ushenko, V. O.; Bodnar, G. B.; Zhytaryuk, V. G.; Prydiy, O. G.; Koval, G.; Lukashevich, I.; Vanchuliak, O.

    2018-01-01

    The paper consists of two parts. The first part presents short theoretical basics of the method of azimuthally-invariant Mueller-matrix description of optical anisotropy of biological tissues. It was provided experimentally measured coordinate distributions of Mueller-matrix invariants (MMI) of linear and circular birefringences of skeletal muscle tissue. It was defined the values of statistic moments, which characterize the distributions of amplitudes of wavelet coefficients of MMI at different scales of scanning. The second part presents the data of statistic analysis of the distributions of amplitude of wavelet coefficients of the distributions of linear birefringence of myocardium tissue died after the infarction and ischemic heart disease. It was defined the objective criteria of differentiation of the cause of death.

  17. Multiscale polarization diagnostics of birefringent networks in problems of necrotic changes diagnostics

    NASA Astrophysics Data System (ADS)

    Sakhnovskiy, M. Yu.; Ushenko, Yu. O.; Ushenko, V. O.; Besaha, R. N.; Pavlyukovich, N.; Pavlyukovich, O.

    2018-01-01

    The paper consists of two parts. The first part presents short theoretical basics of the method of azimuthally-invariant Mueller-matrix description of optical anisotropy of biological tissues. It was provided experimentally measured coordinate distributions of Mueller-matrix invariants (MMI) of linear and circular birefringences of skeletal muscle tissue. It was defined the values of statistic moments, which characterize the distributions of amplitudes of wavelet coefficients of MMI at different scales of scanning. The second part presents the data of statistic analysis of the distributions of amplitude of wavelet coefficients of the distributions of linear birefringence of myocardium tissue died after the infarction and ischemic heart disease. It was defined the objective criteria of differentiation of the cause of death.

  18. Wavelet analysis of birefringence images of myocardium tissue

    NASA Astrophysics Data System (ADS)

    Sakhnovskiy, M. Yu.; Ushenko, Yu. O.; Kushnerik, L.; Soltys, I. V.; Pavlyukovich, N.; Pavlyukovich, O.

    2018-01-01

    The paper consists of two parts. The first part presents short theoretical basics of the method of azimuthally-invariant Mueller-matrix description of optical anisotropy of biological tissues. It was provided experimentally measured coordinate distributions of Mueller-matrix invariants (MMI) of linear and circular birefringences of skeletal muscle tissue. It was defined the values of statistic moments, which characterize the distributions of amplitudes of wavelet coefficients of MMI at different scales of scanning. The second part presents the data of statistic analysis of the distributions of amplitude of wavelet coefficients of the distributions of linear birefringence of myocardium tissue died after the infarction and ischemic heart disease. It was defined the objective criteria of differentiation of the cause of death.

  19. Climate-change-driven accelerated sea-level rise detected in the altimeter era.

    PubMed

    Nerem, R S; Beckley, B D; Fasullo, J T; Hamlington, B D; Masters, D; Mitchum, G T

    2018-02-27

    Using a 25-y time series of precision satellite altimeter data from TOPEX/Poseidon, Jason-1, Jason-2, and Jason-3, we estimate the climate-change-driven acceleration of global mean sea level over the last 25 y to be 0.084 ± 0.025 mm/y 2 Coupled with the average climate-change-driven rate of sea level rise over these same 25 y of 2.9 mm/y, simple extrapolation of the quadratic implies global mean sea level could rise 65 ± 12 cm by 2100 compared with 2005, roughly in agreement with the Intergovernmental Panel on Climate Change (IPCC) 5th Assessment Report (AR5) model projections. Copyright © 2018 the Author(s). Published by PNAS.

  20. The remapping of space in motor learning and human-machine interfaces

    PubMed Central

    Mussa-Ivaldi, F.A.; Danziger, Z.

    2009-01-01

    Studies of motor adaptation to patterns of deterministic forces have revealed the ability of the motor control system to form and use predictive representations of the environment. One of the most fundamental elements of our environment is space itself. This article focuses on the notion of Euclidean space as it applies to common sensory motor experiences. Starting from the assumption that we interact with the world through a system of neural signals, we observe that these signals are not inherently endowed with metric properties of the ordinary Euclidean space. The ability of the nervous system to represent these properties depends on adaptive mechanisms that reconstruct the Euclidean metric from signals that are not Euclidean. Gaining access to these mechanisms will reveal the process by which the nervous system handles novel sophisticated coordinate transformation tasks, thus highlighting possible avenues to create functional human-machine interfaces that can make that task much easier. A set of experiments is presented that demonstrate the ability of the sensory-motor system to reorganize coordination in novel geometrical environments. In these environments multiple degrees of freedom of body motions are used to control the coordinates of a point in a two-dimensional Euclidean space. We discuss how practice leads to the acquisition of the metric properties of the controlled space. Methods of machine learning based on the reduction of reaching errors are tested as a means to facilitate learning by adaptively changing he map from body motions to controlled device. We discuss the relevance of the results to the development of adaptive human machine interfaces and optimal control. PMID:19665553

  1. Screen-Printed Washable Electronic Textiles as Self-Powered Touch/Gesture Tribo-Sensors for Intelligent Human-Machine Interaction.

    PubMed

    Cao, Ran; Pu, Xianjie; Du, Xinyu; Yang, Wei; Wang, Jiaona; Guo, Hengyu; Zhao, Shuyu; Yuan, Zuqing; Zhang, Chi; Li, Congju; Wang, Zhong Lin

    2018-05-22

    Multifunctional electronic textiles (E-textiles) with embedded electric circuits hold great application prospects for future wearable electronics. However, most E-textiles still have critical challenges, including air permeability, satisfactory washability, and mass fabrication. In this work, we fabricate a washable E-textile that addresses all of the concerns and shows its application as a self-powered triboelectric gesture textile for intelligent human-machine interfacing. Utilizing conductive carbon nanotubes (CNTs) and screen-printing technology, this kind of E-textile embraces high conductivity (0.2 kΩ/sq), high air permeability (88.2 mm/s), and can be manufactured on common fabric at large scales. Due to the advantage of the interaction between the CNTs and the fabrics, the electrode shows excellent stability under harsh mechanical deformation and even after being washed. Moreover, based on a single-electrode mode triboelectric nanogenerator and electrode pattern design, our E-textile exhibits highly sensitive touch/gesture sensing performance and has potential applications for human-machine interfacing.

  2. A comparison of optimal MIMO linear and nonlinear models for brain machine interfaces

    NASA Astrophysics Data System (ADS)

    Kim, S.-P.; Sanchez, J. C.; Rao, Y. N.; Erdogmus, D.; Carmena, J. M.; Lebedev, M. A.; Nicolelis, M. A. L.; Principe, J. C.

    2006-06-01

    The field of brain-machine interfaces requires the estimation of a mapping from spike trains collected in motor cortex areas to the hand kinematics of the behaving animal. This paper presents a systematic investigation of several linear (Wiener filter, LMS adaptive filters, gamma filter, subspace Wiener filters) and nonlinear models (time-delay neural network and local linear switching models) applied to datasets from two experiments in monkeys performing motor tasks (reaching for food and target hitting). Ensembles of 100-200 cortical neurons were simultaneously recorded in these experiments, and even larger neuronal samples are anticipated in the future. Due to the large size of the models (thousands of parameters), the major issue studied was the generalization performance. Every parameter of the models (not only the weights) was selected optimally using signal processing and machine learning techniques. The models were also compared statistically with respect to the Wiener filter as the baseline. Each of the optimization procedures produced improvements over that baseline for either one of the two datasets or both.

  3. A comparison of optimal MIMO linear and nonlinear models for brain-machine interfaces.

    PubMed

    Kim, S-P; Sanchez, J C; Rao, Y N; Erdogmus, D; Carmena, J M; Lebedev, M A; Nicolelis, M A L; Principe, J C

    2006-06-01

    The field of brain-machine interfaces requires the estimation of a mapping from spike trains collected in motor cortex areas to the hand kinematics of the behaving animal. This paper presents a systematic investigation of several linear (Wiener filter, LMS adaptive filters, gamma filter, subspace Wiener filters) and nonlinear models (time-delay neural network and local linear switching models) applied to datasets from two experiments in monkeys performing motor tasks (reaching for food and target hitting). Ensembles of 100-200 cortical neurons were simultaneously recorded in these experiments, and even larger neuronal samples are anticipated in the future. Due to the large size of the models (thousands of parameters), the major issue studied was the generalization performance. Every parameter of the models (not only the weights) was selected optimally using signal processing and machine learning techniques. The models were also compared statistically with respect to the Wiener filter as the baseline. Each of the optimization procedures produced improvements over that baseline for either one of the two datasets or both.

  4. Brain-machine interfaces for assistive smart homes: A feasibility study with wearable near-infrared spectroscopy.

    PubMed

    Ogawa, Takeshi; Hirayama, Jun-Ichiro; Gupta, Pankaj; Moriya, Hiroki; Yamaguchi, Shumpei; Ishikawa, Akihiro; Inoue, Yoshihiro; Kawanabe, Motoaki; Ishii, Shin

    2015-08-01

    Smart houses for elderly or physically challenged people need a method to understand residents' intentions during their daily-living behaviors. To explore a new possibility, we here developed a novel brain-machine interface (BMI) system integrated with an experimental smart house, based on a prototype of a wearable near-infrared spectroscopy (NIRS) device, and verified the system in a specific task of controlling of the house's equipments with BMI. We recorded NIRS signals of three participants during typical daily-living actions (DLAs), and classified them by linear support vector machine. In our off-line analysis, four DLAs were classified at about 70% mean accuracy, significantly above the chance level of 25%, in every participant. In an online demonstration in the real smart house, one participant successfully controlled three target appliances by BMI at 81.3% accuracy. Thus we successfully demonstrated the feasibility of using NIRS-BMI in real smart houses, which will possibly enhance new assistive smart-home technologies.

  5. Software Independent Verification and Validation (SIV&V) Simplified

    DTIC Science & Technology

    2006-12-01

    Configuration Item I/O Input/Output I2V2 Independent Integrated Verification and Validation IBM International Business Machines ICD Interface...IPT Integrated Product Team IRS Interface Requirements Specification ISD Integrated System Diagram ITD Integrated Test Description ITP ...programming languages such as COBOL (Common Business Oriented Language) (Codasyl committee 1960), and FORTRAN (FORmula TRANslator) ( IBM 1952) (Robat 11

  6. Software Engineering for User Interfaces. Technical Report.

    ERIC Educational Resources Information Center

    Draper, Stephen W.; Norman, Donald A.

    The discipline of software engineering can be extended in a natural way to deal with the issues raised by a systematic approach to the design of human-machine interfaces. The user should be treated as part of the system being designed and projects should be organized to take into account the current lack of a priori knowledge of user interface…

  7. Intersecting vane machines

    DOEpatents

    Bailey, H. Sterling; Chomyszak, Stephen M.

    2007-01-16

    The invention provides a toroidal intersecting vane machine incorporating intersecting rotors to form primary and secondary chambers whose porting configurations minimize friction and maximize efficiency. Specifically, it is an object of the invention to provide a toroidal intersecting vane machine that greatly reduces the frictional losses through meshing surfaces without the need for external gearing by modifying the function of one or the other of the rotors from that of "fluid moving" to that of "valving" thereby reducing the pressure loads and associated inefficiencies at the interface of the meshing surfaces. The inventions described herein relate to these improvements.

  8. Delivering key signals to the machine: seeking the electric signal that muscles emanate

    NASA Astrophysics Data System (ADS)

    Bani Hashim, A. Y.; Maslan, M. N.; Izamshah, R.; Mohamad, I. S.

    2014-11-01

    Due to the limitation of electric power generation in the human body, present human-machine interfaces have not been successful because of the nature of standard electronics circuit designs, which do not consider the specifications of signals that resulted from the skin. In general, the outcomes and applications of human-machine interfaces are limited to custom-designed subsystems, such as neuroprosthesis. We seek to model the bio dynamical of sub skin into equivalent mathematical definitions, descriptions, and theorems. Within the human skin, there are networks of nerves that permit the skin to function as a multi dimension transducer. We investigate the nature of structural skin. Apart from multiple networks of nerves, there are other segments within the skin such as minute muscles. We identify the segments that are active when there is an electromyography activity. When the nervous system is firing signals, the muscle is being stimulated. We evaluate the phenomena of biodynamic of the muscles that is concerned with the electromyography activity of the nervous system. In effect, we design a relationship between the human somatosensory and synthetic systems sensory as the union of a complete set of the new domain of the functional system. This classifies electromyogram waveforms linked to intent thought of an operator. The system will become the basis for delivering key signals to machine such that the machine is under operator's intent, hence slavery.

  9. Neurosurgery and the dawning age of Brain-Machine Interfaces

    PubMed Central

    Rowland, Nathan C.; Breshears, Jonathan; Chang, Edward F.

    2013-01-01

    Brain–machine interfaces (BMIs) are on the horizon for clinical neurosurgery. Electrocorticography-based platforms are less invasive than implanted microelectrodes, however, the latter are unmatched in their ability to achieve fine motor control of a robotic prosthesis capable of natural human behaviors. These technologies will be crucial to restoring neural function to a large population of patients with severe neurologic impairment – including those with spinal cord injury, stroke, limb amputation, and disabling neuromuscular disorders such as amyotrophic lateral sclerosis. On the opposite end of the spectrum are neural enhancement technologies for specialized applications such as combat. An ongoing ethical dialogue is imminent as we prepare for BMI platforms to enter the neurosurgical realm of clinical management. PMID:23653884

  10. Applications of Brain–Machine Interface Systems in Stroke Recovery and Rehabilitation

    PubMed Central

    Francisco, Gerard E.; Contreras-Vidal, Jose L.

    2014-01-01

    Stroke is a leading cause of disability, significantly impacting the quality of life (QOL) in survivors, and rehabilitation remains the mainstay of treatment in these patients. Recent engineering and technological advances such as brain-machine interfaces (BMI) and robotic rehabilitative devices are promising to enhance stroke neu-rorehabilitation, to accelerate functional recovery and improve QOL. This review discusses the recent applications of BMI and robotic-assisted rehabilitation in stroke patients. We present the framework for integrated BMI and robotic-assisted therapies, and discuss their potential therapeutic, assistive and diagnostic functions in stroke rehabilitation. Finally, we conclude with an outlook on the potential challenges and future directions of these neurotechnologies, and their impact on clinical rehabilitation. PMID:25110624

  11. TAE+ 5.2 - TRANSPORTABLE APPLICATIONS ENVIRONMENT PLUS, VERSION 5.2 (HP9000 SERIES 700/800 VERSION)

    NASA Technical Reports Server (NTRS)

    TAE SUPPORT OFFICE

    1994-01-01

    TAE (Transportable Applications Environment) Plus is an integrated, portable environment for developing and running interactive window, text, and graphical object-based application systems. The program allows both programmers and non-programmers to easily construct their own custom application interface and to move that interface and application to different machine environments. TAE Plus makes both the application and the machine environment transparent, with noticeable improvements in the learning curve. The main components of TAE Plus are as follows: (1) the WorkBench, a What You See Is What You Get (WYSIWYG) tool for the design and layout of a user interface; (2) the Window Programming Tools Package (WPT), a set of callable subroutines that control an application's user interface; and (3) TAE Command Language (TCL), an easy-to-learn command language that provides an easy way to develop an executable application prototype with a run-time interpreted language. The WorkBench tool allows the application developer to interactively construct the layout of an application's display screen by manipulating a set of interaction objects including input items such as buttons, icons, and scrolling text lists. User interface interactive objects include data-driven graphical objects such as dials, thermometers, and strip charts as well as menubars, option menus, file selection items, message items, push buttons, and color loggers. The WorkBench user specifies the windows and interaction objects that will make up the user interface, then specifies the sequence of the user interface dialogue. The description of the designed user interface is then saved into resource files. For those who desire to develop the designed user interface into an operational application, the WorkBench tool also generates source code (C, C++, Ada, and TCL) which fully controls the application's user interface through function calls to the WPTs. The WPTs are the runtime services used by application programs to display and control the user interfaces. Since the WPTs access the workbench-generated resource files during each execution, details such as color, font, location, and object type remain independent from the application code, allowing changes to the user interface without recompiling and relinking. In addition to WPTs, TAE Plus can control interaction of objects from the interpreted TAE Command Language. TCL provides a means for the more experienced developer to quickly prototype an application's use of TAE Plus interaction objects and add programming logic without the overhead of compiling or linking. TAE Plus requires MIT's X Window System and the Open Software Foundation's Motif. The HP 9000 Series 700/800 version of TAE 5.2 requires Version 11 Release 5 of the X Window System. All other machine versions of TAE 5.2 require Version 11, Release 4 of the X Window System. The Workbench and WPTs are written in C++ and the remaining code is written in C. TAE Plus is available by license for an unlimited time period. The licensed program product includes the TAE Plus source code and one set of supporting documentation. Additional documentation may be purchased separately at the price indicated below. The amount of disk space required to load the TAE Plus tar format tape is between 35Mb and 67Mb depending on the machine version. The recommended minimum memory is 12Mb. Each TAE Plus platform delivery tape includes pre-built libraries and executable binary code for that particular machine, as well as source code, so users do not have to do an installation. Users wishing to recompile the source will need both a C compiler and either GNU's C++ Version 1.39 or later, or a C++ compiler based on AT&T 2.0 cfront. TAE Plus was developed in 1989 and version 5.2 was released in 1993. TAE Plus 5.2 is available on media suitable for five different machine platforms: (1) IBM RS/6000 series workstations running AIX (.25 inch tape cartridge in UNIX tar format), (2) DEC RISC workstations running ULTRIX (TK50 cartridge in UNIX tar format), (3) HP9000 Series 700/800 computers running HP-UX 9.x and X11/R5 (HP 4mm DDS DAT tape cartridge in UNIX tar format), (4) Sun4 (SPARC) series computers running SunOS (.25 inch tape cartridge in UNIX tar format), and (5) SGI Indigo computers running IRIX (.25 inch IRIS tape cartridge in UNIX tar format). Please contact COSMIC to obtain detailed information about the supported operating system and OSF/Motif releases required for each of these machine versions. An optional Motif Object Code License is available for the Sun4 version of TAE Plus 5.2. Version 5.1 of TAE Plus remains available for DEC VAX computers running VMS, HP9000 Series 300/400 computers running HP-UX, and HP 9000 Series 700/800 computers running HP-UX 8.x and X11/R4. Please contact COSMIC for details on these versions of TAE Plus.

  12. TAE+ 5.2 - TRANSPORTABLE APPLICATIONS ENVIRONMENT PLUS, VERSION 5.2 (IBM RS/6000 VERSION)

    NASA Technical Reports Server (NTRS)

    TAE SUPPORT OFFICE

    1994-01-01

    TAE (Transportable Applications Environment) Plus is an integrated, portable environment for developing and running interactive window, text, and graphical object-based application systems. The program allows both programmers and non-programmers to easily construct their own custom application interface and to move that interface and application to different machine environments. TAE Plus makes both the application and the machine environment transparent, with noticeable improvements in the learning curve. The main components of TAE Plus are as follows: (1) the WorkBench, a What You See Is What You Get (WYSIWYG) tool for the design and layout of a user interface; (2) the Window Programming Tools Package (WPT), a set of callable subroutines that control an application's user interface; and (3) TAE Command Language (TCL), an easy-to-learn command language that provides an easy way to develop an executable application prototype with a run-time interpreted language. The WorkBench tool allows the application developer to interactively construct the layout of an application's display screen by manipulating a set of interaction objects including input items such as buttons, icons, and scrolling text lists. User interface interactive objects include data-driven graphical objects such as dials, thermometers, and strip charts as well as menubars, option menus, file selection items, message items, push buttons, and color loggers. The WorkBench user specifies the windows and interaction objects that will make up the user interface, then specifies the sequence of the user interface dialogue. The description of the designed user interface is then saved into resource files. For those who desire to develop the designed user interface into an operational application, the WorkBench tool also generates source code (C, C++, Ada, and TCL) which fully controls the application's user interface through function calls to the WPTs. The WPTs are the runtime services used by application programs to display and control the user interfaces. Since the WPTs access the workbench-generated resource files during each execution, details such as color, font, location, and object type remain independent from the application code, allowing changes to the user interface without recompiling and relinking. In addition to WPTs, TAE Plus can control interaction of objects from the interpreted TAE Command Language. TCL provides a means for the more experienced developer to quickly prototype an application's use of TAE Plus interaction objects and add programming logic without the overhead of compiling or linking. TAE Plus requires MIT's X Window System and the Open Software Foundation's Motif. The HP 9000 Series 700/800 version of TAE 5.2 requires Version 11 Release 5 of the X Window System. All other machine versions of TAE 5.2 require Version 11, Release 4 of the X Window System. The Workbench and WPTs are written in C++ and the remaining code is written in C. TAE Plus is available by license for an unlimited time period. The licensed program product includes the TAE Plus source code and one set of supporting documentation. Additional documentation may be purchased separately at the price indicated below. The amount of disk space required to load the TAE Plus tar format tape is between 35Mb and 67Mb depending on the machine version. The recommended minimum memory is 12Mb. Each TAE Plus platform delivery tape includes pre-built libraries and executable binary code for that particular machine, as well as source code, so users do not have to do an installation. Users wishing to recompile the source will need both a C compiler and either GNU's C++ Version 1.39 or later, or a C++ compiler based on AT&T 2.0 cfront. TAE Plus was developed in 1989 and version 5.2 was released in 1993. TAE Plus 5.2 is available on media suitable for five different machine platforms: (1) IBM RS/6000 series workstations running AIX (.25 inch tape cartridge in UNIX tar format), (2) DEC RISC workstations running ULTRIX (TK50 cartridge in UNIX tar format), (3) HP9000 Series 700/800 computers running HP-UX 9.x and X11/R5 (HP 4mm DDS DAT tape cartridge in UNIX tar format), (4) Sun4 (SPARC) series computers running SunOS (.25 inch tape cartridge in UNIX tar format), and (5) SGI Indigo computers running IRIX (.25 inch IRIS tape cartridge in UNIX tar format). Please contact COSMIC to obtain detailed information about the supported operating system and OSF/Motif releases required for each of these machine versions. An optional Motif Object Code License is available for the Sun4 version of TAE Plus 5.2. Version 5.1 of TAE Plus remains available for DEC VAX computers running VMS, HP9000 Series 300/400 computers running HP-UX, and HP 9000 Series 700/800 computers running HP-UX 8.x and X11/R4. Please contact COSMIC for details on these versions of TAE Plus.

  13. TAE+ 5.2 - TRANSPORTABLE APPLICATIONS ENVIRONMENT PLUS, VERSION 5.2 (SUN4 VERSION WITH MOTIF)

    NASA Technical Reports Server (NTRS)

    TAE SUPPORT OFFICE

    1994-01-01

    TAE (Transportable Applications Environment) Plus is an integrated, portable environment for developing and running interactive window, text, and graphical object-based application systems. The program allows both programmers and non-programmers to easily construct their own custom application interface and to move that interface and application to different machine environments. TAE Plus makes both the application and the machine environment transparent, with noticeable improvements in the learning curve. The main components of TAE Plus are as follows: (1) the WorkBench, a What You See Is What You Get (WYSIWYG) tool for the design and layout of a user interface; (2) the Window Programming Tools Package (WPT), a set of callable subroutines that control an application's user interface; and (3) TAE Command Language (TCL), an easy-to-learn command language that provides an easy way to develop an executable application prototype with a run-time interpreted language. The WorkBench tool allows the application developer to interactively construct the layout of an application's display screen by manipulating a set of interaction objects including input items such as buttons, icons, and scrolling text lists. User interface interactive objects include data-driven graphical objects such as dials, thermometers, and strip charts as well as menubars, option menus, file selection items, message items, push buttons, and color loggers. The WorkBench user specifies the windows and interaction objects that will make up the user interface, then specifies the sequence of the user interface dialogue. The description of the designed user interface is then saved into resource files. For those who desire to develop the designed user interface into an operational application, the WorkBench tool also generates source code (C, C++, Ada, and TCL) which fully controls the application's user interface through function calls to the WPTs. The WPTs are the runtime services used by application programs to display and control the user interfaces. Since the WPTs access the workbench-generated resource files during each execution, details such as color, font, location, and object type remain independent from the application code, allowing changes to the user interface without recompiling and relinking. In addition to WPTs, TAE Plus can control interaction of objects from the interpreted TAE Command Language. TCL provides a means for the more experienced developer to quickly prototype an application's use of TAE Plus interaction objects and add programming logic without the overhead of compiling or linking. TAE Plus requires MIT's X Window System and the Open Software Foundation's Motif. The HP 9000 Series 700/800 version of TAE 5.2 requires Version 11 Release 5 of the X Window System. All other machine versions of TAE 5.2 require Version 11, Release 4 of the X Window System. The Workbench and WPTs are written in C++ and the remaining code is written in C. TAE Plus is available by license for an unlimited time period. The licensed program product includes the TAE Plus source code and one set of supporting documentation. Additional documentation may be purchased separately at the price indicated below. The amount of disk space required to load the TAE Plus tar format tape is between 35Mb and 67Mb depending on the machine version. The recommended minimum memory is 12Mb. Each TAE Plus platform delivery tape includes pre-built libraries and executable binary code for that particular machine, as well as source code, so users do not have to do an installation. Users wishing to recompile the source will need both a C compiler and either GNU's C++ Version 1.39 or later, or a C++ compiler based on AT&T 2.0 cfront. TAE Plus was developed in 1989 and version 5.2 was released in 1993. TAE Plus 5.2 is available on media suitable for five different machine platforms: (1) IBM RS/6000 series workstations running AIX (.25 inch tape cartridge in UNIX tar format), (2) DEC RISC workstations running ULTRIX (TK50 cartridge in UNIX tar format), (3) HP9000 Series 700/800 computers running HP-UX 9.x and X11/R5 (HP 4mm DDS DAT tape cartridge in UNIX tar format), (4) Sun4 (SPARC) series computers running SunOS (.25 inch tape cartridge in UNIX tar format), and (5) SGI Indigo computers running IRIX (.25 inch IRIS tape cartridge in UNIX tar format). Please contact COSMIC to obtain detailed information about the supported operating system and OSF/Motif releases required for each of these machine versions. An optional Motif Object Code License is available for the Sun4 version of TAE Plus 5.2. Version 5.1 of TAE Plus remains available for DEC VAX computers running VMS, HP9000 Series 300/400 computers running HP-UX, and HP 9000 Series 700/800 computers running HP-UX 8.x and X11/R4. Please contact COSMIC for details on these versions of TAE Plus.

  14. TAE+ 5.2 - TRANSPORTABLE APPLICATIONS ENVIRONMENT PLUS, VERSION 5.2 (SILICON GRAPHICS VERSION)

    NASA Technical Reports Server (NTRS)

    TAE SUPPORT OFFICE

    1994-01-01

    TAE (Transportable Applications Environment) Plus is an integrated, portable environment for developing and running interactive window, text, and graphical object-based application systems. The program allows both programmers and non-programmers to easily construct their own custom application interface and to move that interface and application to different machine environments. TAE Plus makes both the application and the machine environment transparent, with noticeable improvements in the learning curve. The main components of TAE Plus are as follows: (1) the WorkBench, a What You See Is What You Get (WYSIWYG) tool for the design and layout of a user interface; (2) the Window Programming Tools Package (WPT), a set of callable subroutines that control an application's user interface; and (3) TAE Command Language (TCL), an easy-to-learn command language that provides an easy way to develop an executable application prototype with a run-time interpreted language. The WorkBench tool allows the application developer to interactively construct the layout of an application's display screen by manipulating a set of interaction objects including input items such as buttons, icons, and scrolling text lists. User interface interactive objects include data-driven graphical objects such as dials, thermometers, and strip charts as well as menubars, option menus, file selection items, message items, push buttons, and color loggers. The WorkBench user specifies the windows and interaction objects that will make up the user interface, then specifies the sequence of the user interface dialogue. The description of the designed user interface is then saved into resource files. For those who desire to develop the designed user interface into an operational application, the WorkBench tool also generates source code (C, C++, Ada, and TCL) which fully controls the application's user interface through function calls to the WPTs. The WPTs are the runtime services used by application programs to display and control the user interfaces. Since the WPTs access the workbench-generated resource files during each execution, details such as color, font, location, and object type remain independent from the application code, allowing changes to the user interface without recompiling and relinking. In addition to WPTs, TAE Plus can control interaction of objects from the interpreted TAE Command Language. TCL provides a means for the more experienced developer to quickly prototype an application's use of TAE Plus interaction objects and add programming logic without the overhead of compiling or linking. TAE Plus requires MIT's X Window System and the Open Software Foundation's Motif. The HP 9000 Series 700/800 version of TAE 5.2 requires Version 11 Release 5 of the X Window System. All other machine versions of TAE 5.2 require Version 11, Release 4 of the X Window System. The Workbench and WPTs are written in C++ and the remaining code is written in C. TAE Plus is available by license for an unlimited time period. The licensed program product includes the TAE Plus source code and one set of supporting documentation. Additional documentation may be purchased separately at the price indicated below. The amount of disk space required to load the TAE Plus tar format tape is between 35Mb and 67Mb depending on the machine version. The recommended minimum memory is 12Mb. Each TAE Plus platform delivery tape includes pre-built libraries and executable binary code for that particular machine, as well as source code, so users do not have to do an installation. Users wishing to recompile the source will need both a C compiler and either GNU's C++ Version 1.39 or later, or a C++ compiler based on AT&T 2.0 cfront. TAE Plus was developed in 1989 and version 5.2 was released in 1993. TAE Plus 5.2 is available on media suitable for five different machine platforms: (1) IBM RS/6000 series workstations running AIX (.25 inch tape cartridge in UNIX tar format), (2) DEC RISC workstations running ULTRIX (TK50 cartridge in UNIX tar format), (3) HP9000 Series 700/800 computers running HP-UX 9.x and X11/R5 (HP 4mm DDS DAT tape cartridge in UNIX tar format), (4) Sun4 (SPARC) series computers running SunOS (.25 inch tape cartridge in UNIX tar format), and (5) SGI Indigo computers running IRIX (.25 inch IRIS tape cartridge in UNIX tar format). Please contact COSMIC to obtain detailed information about the supported operating system and OSF/Motif releases required for each of these machine versions. An optional Motif Object Code License is available for the Sun4 version of TAE Plus 5.2. Version 5.1 of TAE Plus remains available for DEC VAX computers running VMS, HP9000 Series 300/400 computers running HP-UX, and HP 9000 Series 700/800 computers running HP-UX 8.x and X11/R4. Please contact COSMIC for details on these versions of TAE Plus.

  15. TAE+ 5.2 - TRANSPORTABLE APPLICATIONS ENVIRONMENT PLUS, VERSION 5.2 (SUN4 VERSION)

    NASA Technical Reports Server (NTRS)

    TAE SUPPORT OFFICE

    1994-01-01

    TAE (Transportable Applications Environment) Plus is an integrated, portable environment for developing and running interactive window, text, and graphical object-based application systems. The program allows both programmers and non-programmers to easily construct their own custom application interface and to move that interface and application to different machine environments. TAE Plus makes both the application and the machine environment transparent, with noticeable improvements in the learning curve. The main components of TAE Plus are as follows: (1) the WorkBench, a What You See Is What You Get (WYSIWYG) tool for the design and layout of a user interface; (2) the Window Programming Tools Package (WPT), a set of callable subroutines that control an application's user interface; and (3) TAE Command Language (TCL), an easy-to-learn command language that provides an easy way to develop an executable application prototype with a run-time interpreted language. The WorkBench tool allows the application developer to interactively construct the layout of an application's display screen by manipulating a set of interaction objects including input items such as buttons, icons, and scrolling text lists. User interface interactive objects include data-driven graphical objects such as dials, thermometers, and strip charts as well as menubars, option menus, file selection items, message items, push buttons, and color loggers. The WorkBench user specifies the windows and interaction objects that will make up the user interface, then specifies the sequence of the user interface dialogue. The description of the designed user interface is then saved into resource files. For those who desire to develop the designed user interface into an operational application, the WorkBench tool also generates source code (C, C++, Ada, and TCL) which fully controls the application's user interface through function calls to the WPTs. The WPTs are the runtime services used by application programs to display and control the user interfaces. Since the WPTs access the workbench-generated resource files during each execution, details such as color, font, location, and object type remain independent from the application code, allowing changes to the user interface without recompiling and relinking. In addition to WPTs, TAE Plus can control interaction of objects from the interpreted TAE Command Language. TCL provides a means for the more experienced developer to quickly prototype an application's use of TAE Plus interaction objects and add programming logic without the overhead of compiling or linking. TAE Plus requires MIT's X Window System and the Open Software Foundation's Motif. The HP 9000 Series 700/800 version of TAE 5.2 requires Version 11 Release 5 of the X Window System. All other machine versions of TAE 5.2 require Version 11, Release 4 of the X Window System. The Workbench and WPTs are written in C++ and the remaining code is written in C. TAE Plus is available by license for an unlimited time period. The licensed program product includes the TAE Plus source code and one set of supporting documentation. Additional documentation may be purchased separately at the price indicated below. The amount of disk space required to load the TAE Plus tar format tape is between 35Mb and 67Mb depending on the machine version. The recommended minimum memory is 12Mb. Each TAE Plus platform delivery tape includes pre-built libraries and executable binary code for that particular machine, as well as source code, so users do not have to do an installation. Users wishing to recompile the source will need both a C compiler and either GNU's C++ Version 1.39 or later, or a C++ compiler based on AT&T 2.0 cfront. TAE Plus was developed in 1989 and version 5.2 was released in 1993. TAE Plus 5.2 is available on media suitable for five different machine platforms: (1) IBM RS/6000 series workstations running AIX (.25 inch tape cartridge in UNIX tar format), (2) DEC RISC workstations running ULTRIX (TK50 cartridge in UNIX tar format), (3) HP9000 Series 700/800 computers running HP-UX 9.x and X11/R5 (HP 4mm DDS DAT tape cartridge in UNIX tar format), (4) Sun4 (SPARC) series computers running SunOS (.25 inch tape cartridge in UNIX tar format), and (5) SGI Indigo computers running IRIX (.25 inch IRIS tape cartridge in UNIX tar format). Please contact COSMIC to obtain detailed information about the supported operating system and OSF/Motif releases required for each of these machine versions. An optional Motif Object Code License is available for the Sun4 version of TAE Plus 5.2. Version 5.1 of TAE Plus remains available for DEC VAX computers running VMS, HP9000 Series 300/400 computers running HP-UX, and HP 9000 Series 700/800 computers running HP-UX 8.x and X11/R4. Please contact COSMIC for details on these versions of TAE Plus.

  16. TAE+ 5.2 - TRANSPORTABLE APPLICATIONS ENVIRONMENT PLUS, VERSION 5.2 (DEC RISC ULTRIX VERSION)

    NASA Technical Reports Server (NTRS)

    TAE SUPPORT OFFICE

    1994-01-01

    TAE (Transportable Applications Environment) Plus is an integrated, portable environment for developing and running interactive window, text, and graphical object-based application systems. The program allows both programmers and non-programmers to easily construct their own custom application interface and to move that interface and application to different machine environments. TAE Plus makes both the application and the machine environment transparent, with noticeable improvements in the learning curve. The main components of TAE Plus are as follows: (1) the WorkBench, a What You See Is What You Get (WYSIWYG) tool for the design and layout of a user interface; (2) the Window Programming Tools Package (WPT), a set of callable subroutines that control an application's user interface; and (3) TAE Command Language (TCL), an easy-to-learn command language that provides an easy way to develop an executable application prototype with a run-time interpreted language. The WorkBench tool allows the application developer to interactively construct the layout of an application's display screen by manipulating a set of interaction objects including input items such as buttons, icons, and scrolling text lists. User interface interactive objects include data-driven graphical objects such as dials, thermometers, and strip charts as well as menubars, option menus, file selection items, message items, push buttons, and color loggers. The WorkBench user specifies the windows and interaction objects that will make up the user interface, then specifies the sequence of the user interface dialogue. The description of the designed user interface is then saved into resource files. For those who desire to develop the designed user interface into an operational application, the WorkBench tool also generates source code (C, C++, Ada, and TCL) which fully controls the application's user interface through function calls to the WPTs. The WPTs are the runtime services used by application programs to display and control the user interfaces. Since the WPTs access the workbench-generated resource files during each execution, details such as color, font, location, and object type remain independent from the application code, allowing changes to the user interface without recompiling and relinking. In addition to WPTs, TAE Plus can control interaction of objects from the interpreted TAE Command Language. TCL provides a means for the more experienced developer to quickly prototype an application's use of TAE Plus interaction objects and add programming logic without the overhead of compiling or linking. TAE Plus requires MIT's X Window System and the Open Software Foundation's Motif. The HP 9000 Series 700/800 version of TAE 5.2 requires Version 11 Release 5 of the X Window System. All other machine versions of TAE 5.2 require Version 11, Release 4 of the X Window System. The Workbench and WPTs are written in C++ and the remaining code is written in C. TAE Plus is available by license for an unlimited time period. The licensed program product includes the TAE Plus source code and one set of supporting documentation. Additional documentation may be purchased separately at the price indicated below. The amount of disk space required to load the TAE Plus tar format tape is between 35Mb and 67Mb depending on the machine version. The recommended minimum memory is 12Mb. Each TAE Plus platform delivery tape includes pre-built libraries and executable binary code for that particular machine, as well as source code, so users do not have to do an installation. Users wishing to recompile the source will need both a C compiler and either GNU's C++ Version 1.39 or later, or a C++ compiler based on AT&T 2.0 cfront. TAE Plus was developed in 1989 and version 5.2 was released in 1993. TAE Plus 5.2 is available on media suitable for five different machine platforms: (1) IBM RS/6000 series workstations running AIX (.25 inch tape cartridge in UNIX tar format), (2) DEC RISC workstations running ULTRIX (TK50 cartridge in UNIX tar format), (3) HP9000 Series 700/800 computers running HP-UX 9.x and X11/R5 (HP 4mm DDS DAT tape cartridge in UNIX tar format), (4) Sun4 (SPARC) series computers running SunOS (.25 inch tape cartridge in UNIX tar format), and (5) SGI Indigo computers running IRIX (.25 inch IRIS tape cartridge in UNIX tar format). Please contact COSMIC to obtain detailed information about the supported operating system and OSF/Motif releases required for each of these machine versions. An optional Motif Object Code License is available for the Sun4 version of TAE Plus 5.2. Version 5.1 of TAE Plus remains available for DEC VAX computers running VMS, HP9000 Series 300/400 computers running HP-UX, and HP 9000 Series 700/800 computers running HP-UX 8.x and X11/R4. Please contact COSMIC for details on these versions of TAE Plus.

  17. Integrated Multi-Scale Data Analytics and Machine Learning for the Distribution Grid and Building-to-Grid Interface

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Stewart, Emma M.; Hendrix, Val; Chertkov, Michael

    This white paper introduces the application of advanced data analytics to the modernized grid. In particular, we consider the field of machine learning and where it is both useful, and not useful, for the particular field of the distribution grid and buildings interface. While analytics, in general, is a growing field of interest, and often seen as the golden goose in the burgeoning distribution grid industry, its application is often limited by communications infrastructure, or lack of a focused technical application. Overall, the linkage of analytics to purposeful application in the grid space has been limited. In this paper wemore » consider the field of machine learning as a subset of analytical techniques, and discuss its ability and limitations to enable the future distribution grid and the building-to-grid interface. To that end, we also consider the potential for mixing distributed and centralized analytics and the pros and cons of these approaches. Machine learning is a subfield of computer science that studies and constructs algorithms that can learn from data and make predictions and improve forecasts. Incorporation of machine learning in grid monitoring and analysis tools may have the potential to solve data and operational challenges that result from increasing penetration of distributed and behind-the-meter energy resources. There is an exponentially expanding volume of measured data being generated on the distribution grid, which, with appropriate application of analytics, may be transformed into intelligible, actionable information that can be provided to the right actors – such as grid and building operators, at the appropriate time to enhance grid or building resilience, efficiency, and operations against various metrics or goals – such as total carbon reduction or other economic benefit to customers. While some basic analysis into these data streams can provide a wealth of information, computational and human boundaries on performing the analysis are becoming significant, with more data and multi-objective concerns. Efficient applications of analysis and the machine learning field are being considered in the loop.« less

  18. Orthogonal cutting modeling of hybrid CFRP/Ti toward specific cutting energy and induced damage analyses

    NASA Astrophysics Data System (ADS)

    Xu, Jinyang; El Mansori, Mohamed

    2016-10-01

    This paper studied the machinability of hybrid CFRP/Ti stack via the numerical approach. To this aim, an original FE model consisting of three fundamental physical constituents, i.e., CFRP phase, interface and Ti phase, was established in the Abaqus Explicit/code to construct the machining behavior of the composite-to-metal alliance. The CFRP phase was modeled as an equivalent homogeneous material (EHM) by considering its anisotropic behavior relative to the fiber orientation (θ) while the Ti alloy phase was assumed to exhibit isotropic and elastic-plastic behavior. The "interface" linking the "CFRP-to-Ti" contact boundary was physically modeled as an intermediate transition region through the concept of cohesive zone (CZ). Different constitutive laws and damage criteria were implemented to simulate the chip separation process of the bi-material system. The key cutting responses including specific cutting energy consumption, induced subsurface damage, and interface delamination were precisely addressed via the comprehensive FE analyses, and several key conclusions were drawn from this study.

  19. FwWebViewPlus: integration of web technologies into WinCC OA based Human-Machine Interfaces at CERN

    NASA Astrophysics Data System (ADS)

    Golonka, Piotr; Fabian, Wojciech; Gonzalez-Berges, Manuel; Jasiun, Piotr; Varela-Rodriguez, Fernando

    2014-06-01

    The rapid growth in popularity of web applications gives rise to a plethora of reusable graphical components, such as Google Chart Tools and JQuery Sparklines, implemented in JavaScript and run inside a web browser. In the paper we describe the tool that allows for seamless integration of web-based widgets into WinCC Open Architecture, the SCADA system used commonly at CERN to build complex Human-Machine Interfaces. Reuse of widely available widget libraries and pushing the development efforts to a higher abstraction layer based on a scripting language allow for significant reduction in maintenance of the code in multi-platform environments compared to those currently used in C++ visualization plugins. Adequately designed interfaces allow for rapid integration of new web widgets into WinCC OA. At the same time, the mechanisms familiar to HMI developers are preserved, making the use of new widgets "native". Perspectives for further integration between the realms of WinCC OA and Web development are also discussed.

  20. Parsing learning in networks using brain-machine interfaces.

    PubMed

    Orsborn, Amy L; Pesaran, Bijan

    2017-10-01

    Brain-machine interfaces (BMIs) define new ways to interact with our environment and hold great promise for clinical therapies. Motor BMIs, for instance, re-route neural activity to control movements of a new effector and could restore movement to people with paralysis. Increasing experience shows that interfacing with the brain inevitably changes the brain. BMIs engage and depend on a wide array of innate learning mechanisms to produce meaningful behavior. BMIs precisely define the information streams into and out of the brain, but engage wide-spread learning. We take a network perspective and review existing observations of learning in motor BMIs to show that BMIs engage multiple learning mechanisms distributed across neural networks. Recent studies demonstrate the advantages of BMI for parsing this learning and its underlying neural mechanisms. BMIs therefore provide a powerful tool for studying the neural mechanisms of learning that highlights the critical role of learning in engineered neural therapies. Copyright © 2017 Elsevier Ltd. All rights reserved.

Top