Sample records for magn magn mater

  1. Comment on papers ``Effect of Ag substitution on the transport property and magnetoresistance of LaMnO3'' [J. Magn. Magn. Mater. 248 (2002) 26] and ``Possible magnetic phase separation in Ru-doped La0.67Ca0.33O3'' [J. Magn. Magn. Mater. 257 (2003) 195

    NASA Astrophysics Data System (ADS)

    Rozenberg, E.

    2004-03-01

    In recent papers Ye et al. (J. Magn. Magn. Mater. 248 (2002) 26) and Lakshmi et al. (J. Magn. Magn. Mater. 257 (2003) 195) reported the characteristic features of electrical resistivity ( ρ) versus temperature ( T) dependences of polycrystalline-doped manganites La 1- xAg xMnO 3 and La 0.67Ca 0.33Mn 1- xRu xO 3. Infact, two peaks on ρ( T) curve coexist: broad one at some Tmax below the Curie points ( TC) of these compounds and a sharp peak near TC. Authors interpreted such coexistence as an evidence of electronic/magnetic phase separation in the above-noted systems below its TC. It is shown in this comment that such an interpretation is obviously invalid for La 1- xAg xMnO 3 system and is very questionable for La 0.67Ca 0.33Mn 1- xRu xO 3. The simplest and natural reason for the appearance of considered features on ρ( T) dependences of polycrystalline manganites is the well-known grain-boundary effects.

  2. MagneMotion urban maglev : final report

    DOT National Transportation Integrated Search

    2004-11-01

    The MagneMotion Urban Maglev System, called M3, is designed as an alternative to all conventional guided transportation systems. Advantages include major reductions in travel time, operating cost, capital cost, noise, and energy consumption. Small ve...

  3. Modèle tridimensionnel pour coupler les équations magnétiques et électriques dans le cas de la magnétostatique

    NASA Astrophysics Data System (ADS)

    Piriou, F.; Razek, A.

    1991-03-01

    In this paper a 3D model for coupling of magnetic and electric equations is presented. The magnetic equations are solved with the help of finite element method using the magnetic vector potential formulation. To take into account the effects of magnetic saturation we use the Newton-Raphson algorithm. We develop the analysis permitting the coupling of magnetic and electric equations to obtain a difrerential system equations which can be solved with numerical integration. As example we model an iron core coil and the validity of our model is verified by a comparison of the obtained results with an analytical solution and a 2D code calculation. Dans cet article est présenté un modèle 3D qui permet de coupler les équations magnétiques et électriques. Les équations magnétiques sont résolues à l'aide de la méthode des éléments finis en utilisant une formulation en potentiel vecteur magnétique. Dans le modèle proposé les effets de la saturation du circuit magnétique sont pris en compte en utilisant l'algorithme de Newton-Raphson. On montre comment relier les équations magnétiques avec celles du circuit électrique pour aboutir à un système d'équations différentielles que l'on résout avec une intégration numérique. A titre d'exemple on modélise une bobine à noyau ferromagnétique et pour montrer la validité du modèle on compare les résultats obtenus avec une solution analytique et un code de calcul 2D.

  4. Reconstrução tridimensional de arcos magnéticos por tomografia

    NASA Astrophysics Data System (ADS)

    Simões, P. J. A.; Costa, J. E. R.

    2003-08-01

    Uma explosão solar é uma variação súbita do brilho que ocorre nas regiões ativas da atmosfera solar. Estas regiões são constituídas por um plasma magnetizado com intensa indução magnética e em cenários bem complexos como visto recentemente através de experimentos embarcados em satélites operando instrumentos em raios X moles e ultra-violeta distante. A energia magnética, que pode ser armazenada por um período de horas até dias em configurações magnéticas estressadas, é subitamente lançada na atmosfera solar e transferida para partículas como elétrons, prótons e núcleos pesados, que são acelerados e/ou aquecidos, produzindo radiação eletromagnética. A proposta final deste projeto é determinar as características espaciais de alta resolução da emissão e polarização girossincrotrônica de explosões solares em ambientes complexos de campos magnéticos. Os recentes resultados da emissão difusa em EUV apresentado pelos satélites TRACE e SOHO dos arcos magnéticos conectando as diferentes polaridades magnéticas sobre as regiões ativas possibilitam novas abordagens sobre o papel do campo magnético na emissão em rádio. Nesta etapa apresentamos os resultados da reconstrução da geometria tridimensional das linhas de força destes arcos utilizando técnicas tomográficas, a partir de imagens de alta resolução espacial obtidas pelo instrumento EIT (Extreme ultraviolet Imaging Telescope), além da modelagem das induções magnéticas por um campo dipolar e as densidades de partículas aceleradas. Utilizamos para a reconstrução geométrica, imagens tomadas em vários ângulos dos arcos devido à rotacão solar. Com estes resultados, daremos continuidade ao projeto, com os cálculos da transferência radiativa nos modos ordinário e extraordinário de propagação da radiação girossincrotrônica de explosões solares.

  5. Switching adhesion forces by crossing the metal–insulator transition in Magnéli-type vanadium oxide crystals

    PubMed Central

    Klemm, Matthias; Horn, Siegfried; Woydt, Mathias

    2011-01-01

    Summary Magnéli-type vanadium oxides form the homologous series VnO2 n -1 and exhibit a temperature-induced, reversible metal–insulator first order phase transition (MIT). We studied the change of the adhesion force across the transition temperature between the cleavage planes of various vanadium oxide Magnéli phases (n = 3 … 7) and spherical titanium atomic force microscope (AFM) tips by systematic force–distance measurements with a variable-temperature AFM under ultrahigh vacuum conditions (UHV). The results show, for all investigated samples, that crossing the transition temperatures leads to a distinct change of the adhesion force. Low adhesion corresponds consistently to the metallic state. Accordingly, the ability to modify the electronic structure of the vanadium Magnéli phases while maintaining composition, stoichiometry and crystallographic integrity, allows for relating frictional and electronic material properties at the nano scale. This behavior makes the vanadium Magnéli phases interesting candidates for technology, e.g., as intelligent devices or coatings where switching of adhesion or friction is desired. PMID:21977416

  6. Modélisation d'un transformateur à shunts magnétiques utilisé dans l'alimentation H.T. d'un générateur micro-ondes à magnétron

    NASA Astrophysics Data System (ADS)

    Chraygane, Mohamed; Teissier, Maurice; Jammal, Ahmad; Masson, Jean-Pierre

    1994-11-01

    The high voltage power supply for magnetron, used for the modular microwave generators in industrial applications, is of a classical design : a single phase leakage flux transformer supplying a cell, composed of a capacitor and a diode, which multiplies the voltage and stabilizes the current. A π model of this transformer is developed, taking the saturation phenomena and the stabilization process of the magnetron current into account. Three inductances are characterized by the non linear relations between flux and magnetizing current. This model was tested by E.M.T.P. software (Electro-Magnetic Transients Program), near the nominal state. The theoretical results were compared to experimental measurements with a good agreement. L'alimentation haute tension des magnétrons, utilisés comme source d'énergie microondes dans l'industrie, est de conception classique : un transformateur monophasé à fuites magnétiques alimentant une cellule doubleuse de tension et stabilisatrice de courant. Un schéma équivalent en π du transformateur est présenté, prenant en compte la saturation des différentes parties du fer et la stabilisation du courant du magnétron. Trois inductances sont caractérisées par les relations non linéaires entre flux et courant magnétisant. Ce modèle a été testé à l'aide du logiciel de calcul E.M.T.P. (Electro-Magnetic Transients Program), au voisinage du régime nominal. Les résultats théoriques, comparés aux mesures expérimentales, se trouvent en bon accord avec elles.

  7. Automated high-throughput purification of genomic DNA from plant leaf or seed using MagneSil paramagnetic particles

    NASA Astrophysics Data System (ADS)

    Bitner, Rex M.; Koller, Susan C.

    2004-06-01

    Three different methods of automated high throughput purification of genomic DNA from plant materials processed in 96 well plates are described. One method uses MagneSil paramagnetic particles to purify DNA present in single leaf punch samples or small seed samples, using 320ul capacity 96 well plates which minimizes reagent and plate costs. A second method uses 2.2 ml and 1.2 ml capacity plates and allows the purification of larger amounts of DNA from 5-6 punches of materials or larger amounts of seeds. The third method uses the MagneSil ONE purification system to purify a fixed amount of DNA, thus simplifying the processing of downstream applications by normalizing the amounts of DNA so they do not require quantitation. Protocols for the purification of a fixed yield of DNA, e.g. 1 ug, from plant leaf or seed samples using MagneSil paramagnetic particles and a Beckman-Coulter BioMek FX robot are described. DNA from all three methods is suitable for applications such as PCR, RAPD, STR, READIT SNP analysis, and multiplexed PCR systems. The MagneSil ONE system is also suitable for use with SNP detection systems such as Third Wave Technology"s Invader methods.

  8. Oxygen deficient Ti oxides (natural magnéli phases) from mudstone xenoliths with native iron from Disko, central West Greenland

    NASA Astrophysics Data System (ADS)

    Pedersen, A. K.; Rønsbo, J. G.

    1987-05-01

    Mudstone xenoliths in a strongly reduced andesitic subaquatic breccia with native iron from the Asuk Member on Disko contain Ti oxides which are oxygen deficient relative to rutile. Ore microscopy reveals that the mudstone xenoliths contain former clastic oxide grains which have equilibrated to blue Ti oxides and grey aluminous Ti oxides. They also contain still immature coal fragments in a glassy matrix with native iron. The blue oxides are compositionally similar to magnéli phases TinO2n-1 within the range n=4 to 7, and several grains contain more than one natural magnéli phase. Two other phases found are 1) pale orange blebs in magnéli phases with a composition approaching Al1Ti{1/3+}Ti{2/4+}O7 (AlTi phase B) and 2) grey oxide rims on magnéli phases or independent grains of the compositional series Al2-x(Ti{0.5/4+}(Mg,Fe)0.5)xTi{n-2/4+}O2n-1 with n mostly between 7 and 10 (AlTi phase A). The natural magnéli phases equilibrated at oxygen fugacities 4 to 5 log units below the Fe-W oxygen buffer at igneous temperatures and represent the most reduced high-temperature environment yet recorded among native iron bearing rocks from Disko. The extremely reducing conditions were met in rocks where coal fragments were still in a state of degassing hydrocarbon components at the time of quenching. Field geology and carbon barometry indicate equilibration at pressures of less than 10 bars.

  9. Occurrence and possible significance of rare Ti oxides (Magneli phases) in carbonaceous chondrite matrices

    NASA Technical Reports Server (NTRS)

    Brearley, Adrian J.

    1993-01-01

    Rare, ultrafine-grained Ti oxides (Ti3O5 and the Magneli phases, Ti5O9 and Ti8O15) have been identified by TEM in the CM2 carbonaceous chondrite, Bells, and a carbonaceous chondrite matrix clast from the Nilpena polymict ureilite. In both meteorites the Ti oxides occur in the matrix as isolated grains and clusters of two or more grains. They are euhedral in shape and have grain sizes of 0.05-0.3 micron. Magneli phases have been recently shown to be a common component in some interplanetary dust particles, but this is the first reported occurrence in a meteorite. The morphological properties and grain size of the Ti oxides are consistent with formation by vapor phase condensation either within the solar nebula or possibly in a presolar environment.

  10. Modeling the Thermoelectric Properties of Ti5O9 Magneli Phase Ceramics

    DTIC Science & Technology

    2016-07-14

    these ceramics were investigated from room temperature to 1076 K. We show that the experimental variation of the electrical conduc- tivity with...figure-of-merit ZT of this nanoceramic material reaches 0.3 K at 1076 K. Key words: Thermoelectrics, nanoceramics, magnéli phase, small polaron...be obtained from the previous data. Thermal conductivity values were extrapolated for 876 K, 975 K, and 1076 K to match the range of thermopower and

  11. Magnétochiralité et résonances stochastiques dans les lasers

    NASA Astrophysics Data System (ADS)

    Bonnet, C.; Bretenaker, F.; Brunel, M.; Chauvat, D.; Emile, O.; Lai, N. D.; Le Floch, A.; Ropars, G.; Ruchon, T.; Singh, K.; Thépot, J.-Y.; Vallet, M.

    2002-06-01

    Les états propres d'un laser constituent un outil de choix pour étudier les différents rôles joués par le bruit dans un système. D'une part, si on veut isoler un effet petit difficilement accessible par les méthodes classiques, ces états propres permettent de réaliser des mesures différentielles de haute précision, à condition de pouvoir éliminer les bruits mécaniques, optiques, électroniques. A titre d'exemple, nous avons utilisé les états propageant et contrapropageant d'un laser ionique en anneau pour mesurer une interaction fondamentale faible: la biréfringence magnétochirale. Cette "biréfringence" se manifeste en effet par une petite variation d'indice selon le sens de parcours de l'anneau, de l'ordre de Δ n.10^{-11}, indépendante de la polarisation. A l'opposé, les deux états propres d'un laser du type Fabry-Perot constituent un système idéal pour explorer les résonances stochastiques à deux dimensions. Les résonances stochastiques par inhibition et par rotation sont isolées en présence de bruits blancs gaussiens tant pour les bruits optiques que magnétiques. L'utilisation possible de l'émission spontanée comme bruit actif est démontrée.

  12. Estudio de la envoltura fría en presencia de un campo magnético en estrellas tempranas

    NASA Astrophysics Data System (ADS)

    Montero, M. F.; Platzeck, A. M.

    En el estudio de la distribución espacial de la densidad en torno a estrellas tempranas, al menos en dos coordenadas, se consideran en general ``escenarios" cualitativos. Existen sólo dos modelos calculados a partir de la ecuación de conservación de momento: el de Poeckert y Marlborough (Astroph. Journal 220, 940, 1978) y el de Ringuelet e Iglesias (Astroph. Journal 369, 463, 1991). El primero es isotermo considerando campo gravitatorio y fuerza centrífuga. El segundo, resuelve un caso no isotermo en equilibrio hidrostático teniendo en cuenta los campos gravitatorios, de radiación y magnético. En esta comunicación presentamos el análisis, que se deriva de los resultados de Ringuelet e Iglesias para el caso hidrostático, de la estructura de líneas de campo magnético. A continuación estudiamos la forma en que se modifica la distribución espacial de la densidad en la envoltura fría, cuando se tiene en cuenta el movimiento del plasma.

  13. Etude de la structure électronique et magnétique de CrO_2

    NASA Astrophysics Data System (ADS)

    Matar, S.; Demazeau, G.; Sticht, J.; Eyert, V.; Kübler, J.

    1992-03-01

    The electronic and magnetic properties of CrO2 were investigated using the self-consistent A.S.W. method in a new approach to study the evolution of its magnetic properties at deceasing volume and to assess recent photoemission results on thin films. The results show that a magnetic transition of ferro Rightarrow antiferromagnetic type is likely to be induced under pressure. Experimental results could be explained by a compression of the CrO6 octahedron within the cell. Les propriétés électroniques de CrO2 ont été déterminées par la méthode auto-cohérente de l'onde sphérique augmentée : A.S.W. Cette étude est menée dans le cadre d'une nouvelle approche visant à définir lévolution de ses propriétés magnétiques à volume décroissant d'une part et à élucider les résultats expérimentaux récents de photoémission sur couches minces d'autre part. Les résultats des calculs montrent qu'une transition magnétique de type ferro Rightarrow antiferromagnétique est susceptible d'être induite sous l'effet de la pression. Les résultats expérimentaux pourraient être interprétés par une compression de l'octaèdre CrO6 au sein de la maille.

  14. Peculiaridades observadas no espectro da estrela magnética HD 190073 - candidata a estrela do tipo Ae de Herbig

    NASA Astrophysics Data System (ADS)

    Franco, G. A. P.; Pogodin, M. A.; Lopes, D. F.

    2003-08-01

    Apresentaremos os resultados de uma investigação espectroscópica cooperativa da estrela magnética HD 190073. As observações foram conduzidas no Observatório do Pico dos Dias (LNA/MCT), European Southern Observatory (ESO, Chile), e Crimean Astrophysical Observatory (CrAO, Ucrânia), entre 1998 e 2002. Discutiremos em detalhe um dos padrões mais marcantes do espectro desse objeto - as multicomponentes em absorção das linhas Ca ii K e H. De acordo com nossos resultados, a estrutura complexa desse perfil permaneceu constante durante várias decadas (dos anos 30 até os anos 80) após o que apresentou mudanças marcantes nos anos 90. Essa variabilidade apresenta óbvia contradição com a interpretação tradicional desse fenômeno como o resultado de espalhamento ressonante atuando seletivamente sobre o vento estelar em distâncias diferentes. Propomos uma explicação alternativa com base em uma topologia especí fica do campo magnético estelar. Essa hipótese permite, também, explicar uma série de outras peculiaridades observadas no envoltório de HD 190073, tais como: (a) a baixa velocidade de rotação pode ser o resultado da interação entre a magnetosfera estelar e um disco equatorial hipotético; (b) o gás circumstelar acumulado em loops magnéticos em latitudes intermediárias pode estimular a formação de regiões gasosas densas a distâncias intermediárias da estrela, onde linhas em emissão com perfil simples são formadas.

  15. Discovery and ramifications of incidental Magnéli phase generation and release from industrial coal-burning.

    PubMed

    Yang, Yi; Chen, Bo; Hower, James; Schindler, Michael; Winkler, Christopher; Brandt, Jessica; Di Giulio, Richard; Ge, Jianping; Liu, Min; Fu, Yuhao; Zhang, Lijun; Chen, Yuru; Priya, Shashank; Hochella, Michael F

    2017-08-08

    Coal, as one of the most economic and abundant energy sources, remains the leading fuel for producing electricity worldwide. Yet, burning coal produces more global warming CO 2 relative to all other fossil fuels, and it is a major contributor to atmospheric particulate matter known to have a deleterious respiratory and cardiovascular impact in humans, especially in China and India. Here we have discovered that burning coal also produces large quantities of otherwise rare Magnéli phases (Ti x O 2x-1 with 4 ≤ x ≤ 9) from TiO 2 minerals naturally present in coal. This provides a new tracer for tracking solid-state emissions worldwide from industrial coal-burning. In its first toxicity testing, we have also shown that nanoscale Magnéli phases have potential toxicity pathways that are not photoactive like TiO 2 phases, but instead seem to be biologically active without photostimulation. In the future, these phases should be thoroughly tested for their toxicity in the human lung.Solid-state emissions from coal burning remain an environmental concern. Here, the authors have found that TiO2 minerals present in coal are converted into titanium suboxides during burning, and initial biotoxicity screening suggests that further testing is needed to look into human lung consequences.

  16. Hybrid Epitaxial Structures for Spintronics

    DTIC Science & Technology

    2002-06-03

    superlat- magnetic resonance (NMR) measurements on the short tice have a perpendicular magnetization, which are range chemical order in combination...Groot, EM. Mueller, PG. van Engen , K.H.J. Buschow, [76] EG. Monzon, M.L. Roukes, J. Magn. Magn. Mater. 198-199 Phys. Rev. Lett. 50 (1983) 2024-2027

  17. Modélisation du champ magnétique d'un propulseur M.H.D. annulaire

    NASA Astrophysics Data System (ADS)

    Kom, C. H.; Brunet, Y.

    1995-01-01

    Stray fields have to be as small as possible to reduce the magnetic signature of the vessel in M.H.D. propulsion where the magnetic field has to be very high. The calculation of the magnetic field of an angular M.H.D. thruster is presented. The field is produced by a distribution of superconducting magnets in the shape of sectors. An analytical formulation of the field can be used in the active zone, outside the coil ends. An analytical method using a Fourier development of the current sheets is employed for an inductor in cylindrical sectors, and a direct method is used for a massive inductor. Numerical and analytical results are compared. Pour des raisons de discrétion, les champs de fuite doivent être minimisés en propulsion M.H.D. où les champs magnétiques doivent être intenses. Le calcul du champ magnétique d'un propulseur M.H.D. naval annulaire, constitué de secteurs inducteurs supraconducteurs est représenté. Dans la zone active, hors des têtes de bobines, une formulation analytique peut être utilisée. Une méthode analytique utilisant le développemment en série de Fourier du courant est adoptée pour les industeurs cylindriques, et une méthode directe pour les inducteurs massifs. Les résultats numériques sont comparés à ceux obtenus avec un logiciel d'éléments finis 2D.

  18. Antenna Development for Multifunctional Armor Applications Using Embedded Spin-Torque Nano-Oscillator (STNO) as a Microwave Detector

    DTIC Science & Technology

    2011-08-09

    Tsoi, A. G. M. Jansen, J. Bass, W. C. Chiang, V. Tsoi, and P. Wyder, “Generation and detection of phase-coherent current-driven magnons in magnetic...multilayers”, Nature, vol. 406, pp. 46–48 (2000). [5] M. Tsoi, “Phase-coherent current-driven magnons in magnetic multilayers”, J. Magn. Magn. Mater

  19. Biohazard Detoxification Method Utilizing Magnetic Particles

    DTIC Science & Technology

    2007-05-01

    configurations (noted by the yellow in the flow tube region). These data highlight the importance of the magnetic field gradient in particle capture...Weyhers, F. Specht , J.S. Lucks, Int. J. Pharm. 138(1996) 85. [9] Z.L. Liu, Z.H. Ding, K.L. Yao, J. Magn. Magn. Mater. 265(2003) 98. [10] P.A. Dresco

  20. Modeling the Thermoelectric Properties of Ti5O9 Magnéli Phase Ceramics

    NASA Astrophysics Data System (ADS)

    Pandey, Sudeep J.; Joshi, Giri; Wang, Shidong; Curtarolo, Stefano; Gaume, Romain M.

    2016-11-01

    Magnéli phase Ti5O9 ceramics with 200-nm grain-size were fabricated by hot-pressing nanopowders of titanium and anatase TiO2 at 1223 K. The thermoelectric properties of these ceramics were investigated from room temperature to 1076 K. We show that the experimental variation of the electrical conductivity with temperature follows a non-adiabatic small-polaron model with an activation energy of 64 meV. In this paper, we propose a modified Heikes-Chaikin-Beni model, based on a canonical ensemble of closely spaced titanium t 2g levels, to account for the temperature dependency of the Seebeck coefficient. Modeling of the thermal conductivity data reveals that the phonon contribution remains constant throughout the investigated temperature range. The thermoelectric figure-of-merit ZT of this nanoceramic material reaches 0.3 K at 1076 K.

  1. Electric Machines with Non-Radially Mounted Rectangular Permanent Magnets / Elektriskās Mašīnas Ar Prizmatiskiem Neradiāli Novietotiem Pastāvīgajiem Magnētiem

    NASA Astrophysics Data System (ADS)

    Levin, N.; Pugachev, V.; Dirba, J.; Lavrinovicha, L.

    2013-04-01

    The authors analyze the advantages and disadvantages of brushless synchronous electric machines with radially and non-radially mounted rectangular permanent magnets. The results show that the proposed nonradial mounting of permanent magnets considered in the paper, in several cases (e.g. multi-pole brushless generators with tooth windings of the armature) allows achievement of the following advantages: better technology of manufacturing the electric machine owing to simple packing of the stator winding in the stator open slots, which also increases the copper slot fillfactor; reduction in the mass-and-size of permanent magnets at least twice; significantly lower cost of the electric machine; and, finally, its greater specific power. Darbā tiek analizētas priekšrocības un trūkumi sinhronām bezkontaktu mašīnām ar radiāli un neradiāli novietotiem prizmatiskiem pastāvīgajiem magnētiem. Parādīts, ka vairākos gadījumos, piemēram, daudzpolu bezkontaktu sinhronajos ģeneratoros ar zobu tinumiem, neradiāls pastāvīgo magnētu izvietojums nodrošina vairākas priekšrocības: uzlabojas mašīnas izgatavošanas tehnoloģija, jo statora atvērtajās rievās vieglāk novietot tinumus un iespējams sasniegt augstāku rievas aizpildījuma koeficientu; samazinās pastāvīgo magnētu masa un izmaksas; palielinās mašīnas īpatnēja jauda.

  2. Polysulfide Binding to Several Nanoscale Magnéli Phases Synthesized in Carbon for Long-Life Lithium-Sulfur Battery Cathodes.

    PubMed

    Zubair, Usman; Amici, Julia; Francia, Carlotta; McNulty, David; Bodoardo, Silvia; O'Dwyer, Colm

    2018-06-11

    In Li-S batteries, it is important to ensure efficient reversible conversion of sulfur to lithium polysulfide (LiPS). Shuttling effects caused by LiPS dissolution can lead to reduced performance and cycle life. Although carbon materials rely on physical trapping of polysulfides, polar oxide surfaces can chemically bind LiPS to improve the stability of sulfur cathodes. We show a simple synthetic method that allows high sulfur loading into mesoporous carbon preloaded with spatially localized nanoparticles of several Magnéli-phase titanium oxide (Ti n O 2n-1 ). This material simultaneously suppresses polysulfide shuttling phenomena by chemically binding Li polysulfides onto several Magnéli-phase surfaces in a single cathode and ensures physical confinement of sulfur and LiPS. The synergy between chemical immobilization of significant quantities of LiPS at the surface of several Ti n O 2n-1 phases and physical entrapment results in coulombically efficient high-rate cathodes with long cycle life and high capacity. These cathodes function efficiently at low electrolyte-to-sulfur ratios to provide high gravimetric and volumetric capacities in comparison with their highly porous carbon counterparts. Assembled coin cells have an initial discharge capacity of 1100 mAh g -1 at 0.1C and maintain a reversible capacity of 520 mAh g -1 at 0.2C for more than 500 cycles. Even at 1C, the cell loses only 0.06 % per cycle for 1000 cycles with a coulombic efficiency close to 99 %. © 2018 Wiley-VCH Verlag GmbH & Co. KGaA, Weinheim.

  3. Lévitation magnétique par association d'aimants permanents et de supraconducteurs à haute température critique

    NASA Astrophysics Data System (ADS)

    Hiebel, P.; Tixador, P.; Chaud, X.

    1995-06-01

    Since their discovery in the years 1986/87, the high critical temperature superconductors have reached nowadays performances interesting enough to conceive passive magnetic bearings and suspensions which would combined permanent magnets and naturally stable superconducting pellets. After underlining the principal factors that affect the superconductormagnet interaction, different experimental results are given about vertical and axial forces with some stiffness values. The magnetization curve of a superconductor help to understand the hysteretic behavior of the force as a function of the distance between superconductor and magnet. So called simple and hybrid structures of superconducting magnetic suspension are presented. Finally simple numerical simulations allow to draw some interesting conclusions about both geometry and best fitting structure of permanent magnets. Depuis leur découverte dans les années 1986/87, les supraconducteurs à haute température critique ont désormais atteint des performances intéressantes et rendent envisageables des paliers et suspensions magnétiques passives associant aimants permanents et pastilles supraconductrices naturellement stables. Après avoir indiqué les termes importants influençant l'interaction supraconducteur - aimant, différents relevés expérimentaux sont donnés pour les forces verticales et transversales avec quelques valeurs de raideurs. La courbe d'aimantation d'un supraconducteur permet de comprendre le comportement hystérétique de la force en fonction de la distance supraconducteur-aimant. Les structures dites simple et hybride des suspensions magnétiques supraconductrices sont présentées. Enfin quelques simulations numériques simples permettent de dégager quelques conclusions intéressantes quant aux géométries respectives et aux structures d'aimants permanents les mieux adaptées.

  4. Automated genomic DNA purification options in agricultural applications using MagneSil paramagnetic particles

    NASA Astrophysics Data System (ADS)

    Bitner, Rex M.; Koller, Susan C.

    2002-06-01

    The automated high throughput purification of genomic DNA form plant materials can be performed using MagneSil paramagnetic particles on the Beckman-Coulter FX, BioMek 2000, and the Tecan Genesis robot. Similar automated methods are available for DNA purifications from animal blood. These methods eliminate organic extractions, lengthy incubations and cumbersome filter plates. The DNA is suitable for applications such as PCR and RAPD analysis. Methods are described for processing traditionally difficult samples such as those containing large amounts of polyphenolics or oils, while still maintaining a high level of DNA purity. The robotic protocols have ben optimized for agricultural applications such as marker assisted breeding, seed-quality testing, and SNP discovery and scoring. In addition to high yield purification of DNA from plant samples or animal blood, the use of Promega's DNA-IQ purification system is also described. This method allows for the purification of a narrow range of DNA regardless of the amount of additional DNA that is present in the initial sample. This simultaneous Isolation and Quantification of DNA allows the DNA to be used directly in applications such as PCR, SNP analysis, and RAPD, without the need for separate quantitation of the DNA.

  5. Réalisation de couches minces magnétiques d'hexaferrite de baryum en vue de concevoir un isolateur coplanaire passif

    NASA Astrophysics Data System (ADS)

    Capraro, S.; Nader, C.; Chatelon, J. P.; Le Berre, M.; Rouiller, T.; Bayard, B.; Joisten, H.; Barbier, D.; Rousseau, J. J.

    2005-05-01

    Le développement des dispositifs intégrés employant un ferrite est un objectif majeur pour des applications électroniques dans la gamme hyperfréquence (circulateurs et isolateurs). Les ferrites hexagonaux, tel que l'hexaferrite de baryum (BaFe{12}O{19} ou BaM), présentent un grand intérêt pour de tels dispositifs en raison de leurs grandes résistivités et de leurs perméabilités élevées aux hautes fréquences. Dans cette étude, les couches minces de BaM, sont déposées et optimisées par pulvérisation cathodique RF sur des substrats d'alumine et de silicium. Après dépôt, les films sont amorphes et un recuit thermique à 800° C est nécessaire pour que les couches de BaM cristallisent et présentent des propriétés magnétiques. Les propriétés magnétiques des couches minces de BaM ont été déterminées par VSM, et on constate que le champ coercitif et l'aimantation à saturation atteignent respectivement 330 kA/m et 500 mT. Des isolateurs sont réalisés par dépôt d'une couche conductrice d'or en utilisant la technique du lift-off qui permet la mise en place du ruban signal ainsi que des plans de masse. Les premiers résultats de mesure en transmission ont montré un effet non réciproque qui atteint 8 dB/cm à 50 GHz.

  6. Magnéli phases Ti{sub 4}O{sub 7} and Ti{sub 8}O{sub 15} and their carbon nanocomposites via the thermal decomposition-precursor route

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Conze, S., E-mail: susan.conze@ikts.fraunhofer.de; Veremchuk, I.; Reibold, M.

    2015-09-15

    A new synthetic approach for producing nano-powders of the Magnéli phases Ti{sub 4}O{sub 7}, Ti{sub 8}O{sub 15} and their carbon nanocomposites by thermal decomposition-precursor route is proposed. The formation mechanism of the single-phase carbon nanocomposites (Ti{sub 4}O{sub 7}/C and Ti{sub 8}O{sub 15}/C) from metal–organic precursors is studied using FT-IR, elemental analysis, TG, STA-MS and others. The synthesis parameters and conditions were optimized to prepare the target oxides with the desired microstructure and physical properties. The electrical and transport properties of Ti{sub 4}O{sub 7}/C and Ti{sub 8}O{sub 15}/C are investigated. These nano-materials are n-type semiconductors with relatively low thermal conductivity inmore » contrast to the bulk species. The nanostructured carbon nanocomposites of Magnéli phases achieve a low thermal conductivity close to 1 W/m K at RT. The maximum ZT{sub 570} {sub °C} values are 0.04 for Ti{sub 4}O{sub 7}/C powder nanocomposite and 0.01 for Ti{sub 8}O{sub 15}/C bulk nanocomposite. - Graphical abstract: From the precursor to the produced titanium oxide pellet and its microstructure (SEM, TEM micrographs) as well as results of phase and thermoelectric analyses. - Highlights: • Magnéli phases Ti{sub 4}O{sub 7}/Ti{sub 8}O{sub 15} via thermal decomposition-precursor route is proposed. • The formation mechanism of the nanocomposites Ti{sub 4}O{sub 7}/C and Ti{sub 8}O{sub 15}/C are investigated. • Microstructure of Ti{sub 4}O{sub 7}/C and Ti{sub 8}O{sub 15}/C are examined. • The electrical and transport properties of Ti{sub 4}O{sub 7}/C and Ti{sub 8}O{sub 15}/C are investigated. • The maximum figure of mertit ZT{sub 570} {sub °C} of Ti{sub 4}O{sub 7}/C and Ti{sub 8}O{sub 15}/C are 0.01 and 0.04.« less

  7. Le satellite Encelade source d'ions N+ dans la magnétosphère de Saturne

    NASA Astrophysics Data System (ADS)

    Bouhram, Mehdi; Berthelier, Jean-Jacques; Illiano, Jean-Marie; Smith, Howard T.; Sittler, Edward C.; Crary, Frank J.; Young, Dave T.

    2005-12-01

    xml:lang="fr">RésuméLe premier passage de la sonde Cassini dans l'environnement de Saturne, au dessus de l'anneau E, a mis en évidence l'existence d'un plasma composé d'un mélange d'ions issus des produits de l'eau (H+, O+, OH+, H2O+) avec une faible composante en ions N+ (3 %). A partir d'un modèle simple du transport des ions dans la magnétosphère, nous montrons que la source de ces ions N+ coïncide avec le satellite Encelade. Un tel résultat peut s'expliquer par la présence de composés volatiles tels que l'ammoniac NH3 sur ce satellite de glace, supposé encore actif géologiquement, ou par la présence d'ions N+ d'origine externe préalablement implantés sur sa surface. Pour citer cet article : M. Bouhram et al., C. R. Physique 6 (2005).

  8. Quantum Monte Carlo analysis of a charge ordered insulating antiferromagnet: The Ti 4O 7 Magneli phase

    DOE PAGES

    Benali, Anouar; Shulenburger, Luke; Krogel, Jaron T.; ...

    2016-06-07

    The Magneli phase Ti 4O 7 is an important transition metal oxide with a wide range of applications because of its interplay between charge, spin, and lattice degrees of freedom. At low temperatures, it has non-trivial magnetic states very close in energy, driven by electronic exchange and correlation interactions. We have examined three low- lying states, one ferromagnetic and two antiferromagnetic, and calculated their energies as well as Ti spin moment distributions using highly accurate Quantum Monte Carlo methods. We compare our results to those obtained from density functional theory- based methods that include approximate corrections for exchange and correlation.more » Our results confirm the nature of the states and their ordering in energy, as compared with density-functional theory methods. However, the energy differences and spin distributions differ. Here, a detailed analysis suggests that non-local exchange-correlation functionals, in addition to other approximations such as LDA+U to account for correlations, are needed to simultaneously obtain better estimates for spin moments, distributions, energy differences and energy gaps.« less

  9. Eventos de Desconexão no Cometa P/Halley sob a Ótica do Modelo de Reconexão Magnética

    NASA Astrophysics Data System (ADS)

    Voelzke, M. R.; Matsuura, O. T.

    1998-08-01

    531 imagens contidas no The International Halley Watch Atlas of Large-Scale Phenomena (Brandt et al., 1992) cobrindo o período de setembro de 1985 a julho de 1986 foram analisadas visando identificar, caracterizar as propriedades e correlacionar estruturas morfológicas da cauda de plasma do cometa P/Halley. A análise revelou 47 eventos de desconexão (DEs) (Niedner & Brandt, 1979; Jockers, 1985; Celnik et al., 1988; Delva et al., 1991). A análise completa de todas as imagens encontra-se publicada em Voelzke & Matsuura, 1998. A distribuição dos DEs na distância heliocêntrica apresenta um caráter bimodal possivelmente associado com a distribuição espacial das fronteiras de setor magnético do meio interplanetário. Os 47 DEs fotografados em 47 imagens distintas permitiram determinar 19 origens de DEs, ou seja, o instante em que supostamente o cometa cruzou a fronteira entre setores magnéticos do vento solar. Tais dados cometários foram comparados com dados do vento solar provenientes de medidas realizadas in situ pelas sondas IMP-8, ICE e PVO, que mediram a variação da velocidade do vento solar, da densidade e da pressão dinâmica durante o intervalo analisado. Os dados destas sondas espaciais em conjunto com os da sonda Vega 1 foram usados para determinar o tempo das passagens do lençol de corrente. Com base nos dados das sondas foram calculadas as coordenadas heliográficas retroativas do lençol de corrente na "superfície fonte" dos mapas sinóticos do campo magnético de Hoeksema, 1989. O cálculo retroativo é feito através de um modelo simples de expressão do vento solar com velocidade uniforme, sendo considerada a co-rotação da magnetosfera com o Sol. Este trabalho apresenta os resultados desta comparação e a análise cinemática da origem dos DEs, determinada sob a hipótese que o plasma desconectado de um dado DE afasta-se com velocidade constante do núcleo cometário (Voelzke & Matsuura, 1998) e compara esta análise com outras que

  10. Powder Metallurgy Processing of High-Strength FeCo Alloys (Preprint)

    DTIC Science & Technology

    2008-09-01

    Basu, R.-Hai Yu, J. Q. Xiao, A. Parvizi- Majidi , J. Mat. Sci. 36 (2001) 1451 5. E.P. George, A.N. Gubbi, I. Baker, L. Robertson, Mater. Sci. and Eng...A329–331 (2002) 325 6. R. H. Yu, S. Basu, L. Ren, Y. Zhang, A. Parvizi- Majidi , K. M. Unruh, and J. Q. Xiao, IEEE Trans. Magn., 36, (2000) 3388 7. T

  11. Reconexión magnética en una región activa en decaimiento

    NASA Astrophysics Data System (ADS)

    Mandrini, C. H.; Démoulin, P.; van Driel-Gesztelyi, L.; Schmieder, B.; Bagalá, L. G.; Rovira, M. G.

    Se han obtenido observaciones desde Tierra (Hα y magnetogramas) coordinadas con el Soft X-ray Telescope (SXT), a bordo del satélite japonés Yohkoh, de una región activa bipolar en decaimiento. Estos datos constituyen la base para el estudio de un punto brillante en rayos X (PBX) y de la actividad relacionada con el mismo en distintas capas de la atmósfera solar. Las observaciones muestran que el PBX está relacionado con la aparición de un bipolo menor (~ 1020 Mx) y que su abrillantamiento continuo, así como sus aumentos de brillo esporádicos (``fulguraciones"), son el resultado de la reconexión entre el pequeño arco emergente (visto en Hα como un sistema de filamentos arqueados, SFA) y arcos mayores asociados al campo facular preexistente. Se ha extrapolado el campo magnético observado en la aproximación libre de fuerzas lineal y se ha seguido su evolución a lo largo de la vida del PBX. Se ha calculado la posición de las cuasiseparatrices (CSs) a partir del campo modelado. Las líneas de campo extrapoladas, cuyas bases fotosféricas se encuentran a ambos lados de las CSs, están de acuerdo con las estructuras cromosféricas y coronales observadas. Se ha calculado el espesor de la CD ubicada a lo largo de la polaridad negativa emergente, encontrándose que su variación está de acuerdo con la evolución de la intensidad del PBX; la CS es muy delgada durante la vida del PBX (~ 100 m), mientras que su espesor aumenta considerablemente (>= 10^4 m) cuando el PBX desaparece de las imágenes del SXT. Estos resultados señalan que el abrillantamiento y las ``fulguraciones" de este PBX se deben al proceso de reconexión en 3D que tiene lugar en las CSs.

  12. Effects of ozone, sulfur dioxide, and alpha and delta races of Colletotrichum Lindemuthianum (Sacc. and Magn. ) Bri and Cav. on bean (Phaseolus vulgaris L. )

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Achwanya, O.S.

    1984-01-01

    A number of bean (Phaseolus vulgaris L.) cultivars were evaluated for their responses to the air pollutants ozone and sulfur dioxide singly and in combination, as well as for their reaction to the alpha and delta races of Colletotrichum lindemuthianum (Sacc. and Magn.) Bri and Cav. Variation in response to both the pollutants and the fungus was noted among the cultivars. Anthracnose caused a reduction in the biomass of some cultivars of the order of 50%. A negative correlation of (r = -0.72, p < 0.0001) was found between the disease severity and the total plant biomass. Greater than additivemore » effects of O/sub 3/ + SO/sub 2/ mixtures were demonstrated. Chlorophyll content and biomass were found to be reliable variables for assessing treatment effects. The pollutants appeared to stimulate the disease development. Greater pollutant injury was also in the presence of the anthracnose disease. The results indicated that there was an interaction between the fungal disease and the air pollutants. Implications for evaluating bean cultivars for resistance to C. lindemuthianum under polluted atmosphere are suggested.« less

  13. Elaboration, microstructure, propriétés électriques et magnétiques de matériaux textures dans les systèmes Nd-Ce-Cu-O et Bi-Sr-Ca-Cu-O

    NASA Astrophysics Data System (ADS)

    Dhalenne, G.; Trouilleux, L.; Jegoudez, J.; Revcolevschi, A.; Monod, P.; Kormann, R.; Ganne, J. P.; Motohira, N.; Kitazawa, K.

    1991-11-01

    Superconducting textured materials were grown from the melt by a floating zone technique in the Nd-Ce-Cu-O and Bi-Sr-Ca-Cu-O systems. The influence of growth conditions and starting compositions on the microstructures and phase composition of the samples were studied by optical microscopy under polarized light, electron microprobe analysis and X-ray diffraction. The superconducting properties of these samples were examined by both electrical resistivity and magnetic measurements. A very strong influence of the microstructure on the superconducting properties as well as a magnetic and electrical anisotropy were shown. In the case of the Bi-Sr-Ca-Cu-O system, critical current densities ranging from 1 600 to 3 000 A.cm^{-2} were measured at 77 K. Des matériaux supraconducteurs texturés ont été élaborés à partir de l'état liquide dans les systèmes Nd-Ce-Cu-O et Bi-Sr-Ca-Cu-O par une technique de fusion de zone. L'influence des conditions de croissance et des compositions initiales sur la microstructure des échantillons a été étudiée par microscopie optique en lumière polarisée, microsonde électronique et diffraction des rayons X. Les propriétés supraconductrices des échantillons ont été examinées par des mesures électriques et magnétiques. Il a été observé une forte influence de la microstructure sur les propriétés supraconductrices ainsi qu'une anisotropie électrique et magnétique. Dans le cas du système Bi-Sr-Ca-Cu-O, les densités de courant critique mesurées à 77 K sont comprises entre 1 600 et 3 000 A.cm^{-2}.

  14. Comparison of the ferromagnetic Blume-Emery-Griffiths model and the AF spin-1 longitudinal Ising model at low temperature

    NASA Astrophysics Data System (ADS)

    Thomaz, M. T.; Corrêa Silva, E. V.

    2016-03-01

    We derive the exact Helmholtz free energy (HFE) of the standard and staggered one-dimensional Blume-Emery-Griffiths (BEG) model in the presence of an external longitudinal magnetic field. We discuss in detail the thermodynamic behavior of the ferromagnetic version of the model, which exhibits magnetic field-dependent plateaux in the z-component of its magnetization at low temperatures. We also study the behavior of its specific heat and entropy, both per site, at finite temperature. The degeneracy of the ground state, at T=0, along the lines that separate distinct phases in the phase diagram of the ferromagnetic BEG model is calculated, extending the study of the phase diagram of the spin-1 antiferromagnetic (AF) Ising model in S.M. de Souza and M.T. Thomaz, J. Magn. and Magn. Mater. 354 (2014) 205 [5]. We explore the implications of the equality of phase diagrams, at T=0, of the ferromagnetic BEG model with K/|J| = - 2 and of the spin-1 AF Ising model for D/|J| > 1/2.

  15. Kerr microscopy studies of the effects of bending stress on galfenola)

    NASA Astrophysics Data System (ADS)

    Raghunath, Ganesh; Marana, Michael; Na, Suok-Min; Flatau, Alison

    2014-05-01

    This work deals with using a magneto-optic Kerr effect (MOKE) microscope to optically analyze the evolution of magnetic domains in a rolled and Goss textured galfenol (Fe81Ga19 + 1.0% NbC) sample when subjected to a bending stress. The initial magnetization state of the cantilevered sample was fixed along its length by a 0.3 T permanent magnet. The magnetic state was monitored with the MOKE microscope as a tip load was applied to bend the sample. The magnetic state of galfenol depends on its magneto-elastic properties. A finite element model that incorporates an energy based formulation of magnetostriction [W. D. Armstrong, J. Magn. Magn. Mater. 263(1-2), 208-218 (2003)] was used to investigate the stresses in the sample and the corresponding change in the magnetic induction as bending occurred. A qualitative comparison with the domain pictures is presented, and the experimental micromagnetic behavior results are shown to correlate well to the macro scale bending stress and magnetization results obtained in the FEM simulations.

  16. Synthesis and Self-Assembly of Films Containing FeCoPt Nanoparticles

    DTIC Science & Technology

    2001-04-01

    1989). 5. J.S. Yin and Z.L. Wang. .. Mater. Res. 14, 503 (1999). 6. T . Teranishi, M. Hosoe, T . Tanaka, and M. Miyaka. .1. Phys. Chem. B. 103, 3818 (1999...7. H. Kanazawa; G. Lauhoff; R. Sbiaa; T . Suzuki. Digests of the 8"h Joint MMM-Intermag Conference Jan. 7-11 2001, p. QC-03. 8. D. Weller, A. Moser...L. Folks, M. E. Best, W. Lee, M. F. Toney, M. Schwickert, J.-U. Thiele, and M. F. Doerner, IEEE Trans. Magn. 36, 10 (2000) 9. J. Numazawa and H

  17. Local magnetic moment formation at 119Sn Mössbauer impurity in RFe2 ( R=rare-earth metals) Laves phases compounds

    NASA Astrophysics Data System (ADS)

    de Oliveira, A. L.; de Oliveira, N. A.; Troper, A.

    2010-05-01

    The purpose of the present work is to theoretically study the local magnetic moment formation and the systematics of the magnetic hyperfine fields at a non-magnetic s-p Mössbauer 119Sn impurity diluted on R sites ( R=rare-earth metals) of the cubic Laves phases intermetallic compounds RFe2. One considers that the magnetic hyperfine field has two contributions (i) the contribution from R ions, calculated via an extended Daniel-Friedel [J. Phys. Chem. Solids 24 (1963) 1601] model and (ii) the contribution from the induced magnetic moments arising from the Fe neighboring sites. We have in this case a two-center Blandin-Campbell-like [Phys. Rev. Lett. 31 (1973) 51; J. Magn. Magn. Mater. 1 (1975) 1] problem, where a magnetic 3d-element located at a distance from the 119Sn impurity gives an extra magnetization to a polarized electron gas which is strongly charge perturbed at the 119Sn impurity site. We also include in the model, the nearest-neighbor perturbation due to the translational invariance breaking introduced by the impurity. Our self-consistent total magnetic hyperfine field calculations are in a very good agreement with recent experimental data.

  18. Micromagnetic modal analysis of spin-transfer-driven ferromagnetic resonance of individual nanomagnets

    NASA Astrophysics Data System (ADS)

    Torres, L.; Finocchio, G.; Lopez-Diaz, L.; Martinez, E.; Carpentieri, M.; Consolo, G.; Azzerboni, B.

    2007-05-01

    In a recent investigation Sankey et al. [Phys. Rev. Lett. 96, 227601 (2006)] demonstrated a technique for measuring spin-transfer-driven ferromagnetic resonance in individual ellipsoidal PyCu nanomagnets as small as 30×90×5.5nm3. In the present work, these experiments are analyzed by means of full micromagnetic modeling finding quantitative agreement and enlightening the spatial distribution of the normal modes found in the experiment. The magnetic parameter set used in the computations is obtained by fitting static magnetoresistance measurements. The temperature effect is also included together with all the nonuniform contributions to the effective field as the magnetostatic coupling and the Ampere field. The polarization function of Slonczewski [J. Magn. Magn. Mater. 159, L1 (1996)] is used including its spatial and angular dependences. Experimental spin-transfer-driven ferromagnetic resonance spectra are reproduced using the same currents as in the experiment. The use of full micromagnetic modeling allows us to further investigate the spatial dependence of the modes. The dependence of the normal mode frequency on the dc and the external field together with a comparison to the normal modes induced by a microwave current is also addressed.

  19. NMR Studies of Organic Thin Films

    DTIC Science & Technology

    1994-02-28

    C.G. Chingas, J.B. Miller, and A.N. Garroway , J. Magn. Reson., 1986, 66, 530. 126. D.G. Cory, J.W.M. van Os, and W.S. Veeman, J. Magn. Reson., 1988, 76...Zumbulyadis and J.M. O’Reilly, J. Magn. Reson., 1989, 82, 613. 131. H.A. Resing, A.N. Garroway , D.C. Weber, J. Ferraris, and D. Slotfeldt-Ellingsen, Pure...Natansohn, Polym. Eng. Sci., 1992, 32, 1711. 137. J.B. Miller and A.N. Garroway , J. Magn. Reson., 1989, 82, 529. 138. D.G. Cory, J.B. Miller, R. Turner

  20. NMR Studies of Organic Thin Films

    DTIC Science & Technology

    1993-05-15

    Fiins - 53 125. C.G. Chingas, J.B. Miller, and A.N. Garroway , J. Magn. Reson., 1986, 66, 530. 126. D.G. Cory, J.W.M. van Os, and W.S. Veeman, J. Magn...24, 5294. 130. N. Zumbulyadis and J.M. O’Reilly, J. Magn. Reson., 1989, 82, 613. 131. H.A. Resing, A.N. Garroway , D.C. Weber, J. Ferrais, and D...4, 182. 136. A. Natansohn, Polym. Eng. Sci., 1992, 32, 1711. 137. J.B. Miller and A.N. Garroway , J. Magn. Reson., 1989, 82, 529. 138. D.G. Cory, J.B

  1. Atomic Transport in Metallic Glasses.

    DTIC Science & Technology

    1983-11-01

    Poate, and W.L. Brown, Appl. Phys. Lett. 32 (1978) 461. 14) D. Akhtar, B. Cantor, and R.W. Cahn, Acta Metall. 30 (1982) 1571. 15) P. Gupta , K.N. Tu...Luborsky, 1R. Sato Turtelli, G.P. Soardo and F. Vinai , IEEE Trans. Magn. MAG-17 (1981) 2615. 28) N. Moser and H. KronmTller, J. Magn. Magn. Mat. 19

  2. La stimulation magnétique transcrânienne (SMT) dans la recherche fondamentale et clinique en neuroscience

    PubMed Central

    Valero-Cabré, Antoni; Pascual-Leone, Alvaro; Coubard, Olivier A.

    2011-01-01

    Introduction Les méthodes de stimulation cérébrale non invasives telles que la Stimulation Magnétique Transcrânienne (SMT) sont largement utilisées pour établir des inférences causales sur les relations entre cerveau et comportement. Des applications cliniques basées sur la SMT ont également été développées pour traiter des affections neurologiques ou psychiatriques comme la dépression, la dystonie, la douleur, les acouphènes ou les séquelles d’accident vasculaire cérébral. État des connaissances La SMT fonctionne en induisant de manière non invasive et de manière focale des courants électriques dans des régions corticales, modulant ainsi leur niveau d’activité de façon variable suivant la fréquence, le nombre d’impulsions, les intervalles et la durée de stimulation utilisés. S’agissant du cortex moteur, on sait par exemple que les patterns d’impulsions de SMT à basse fréquence ou ceux délivrées de manière continue tendent à déprimer l’activité locale, tandis que la SMT à haute fréquence et discontinus tend à la potentialiser. Outre ses effets locaux, la SMT peut aussi avoir des effets à distance sur les régions cérébrales, véhiculés par les connections anatomiques et qui dépendent de l’efficacité et du signe de ces connexions. Perspectives Dans le domaine de la recherche fondamentale et des applications thérapeutiques, l’utilisation efficace de la SMT requiert, cependant, la compréhension approfondie de ses principes opérationnels, de ses risques, de ses potentialités et de ses limites. Dans cet article, nous présentons les principes par lesquels opèrent les méthodes de stimulation cérébrale non invasive, et en particulier la SMT. Conclusion À l’issue de sa lecture, le lecteur sera en mesure de discuter de façon critique les études scientifiques et cliniques utilisant la SMT, ainsi que de concevoir des applications SMT suivant une hypothèse a priori dans le domaine de la recherche en

  3. Role of motive forces for the spin torque transfer for nano-structures

    NASA Astrophysics Data System (ADS)

    Barnes, Stewart

    2009-03-01

    Despite an announced imminent commercial realization of spin transfer random access memory (SPRAM) the current theory evolved from that of Slonczewski [1,2] does not conserve energy. Barnes and Maekawa [3] have shown, in order correct this defect, forces which originate from the spin rather than the charge of an electron must be accounted for, this leading to the concept of spin-motive-forces (smf) which must appear in Faraday's law and which significantly modifies the theory for spin-valves and domain wall devices [4]. A multi-channel theory in which these smf's redirect the spin currents will be described. In nano-structures it is now well known that the Kondo effect is reflected by conductance peaks. In essence, the spin degrees of freedom are used to enhance conduction. In a system with nano-magnets and a Coulomb blockade [5] the similar spin channels can be the only means of effective conduction. This results in a smf which lasts for minutes and an enormous magneto-resistance [5]. This implies the possibility of ``single electron memory'' in which the magnetic state is switched by a single electron. [4pt] [1] J. C. Slonczewski, Current-Driven Excitation of Magnetic Multilayers J. Magn. Magn. Mater. 159, L1 (1996). [0pt] [2] Y. Tserkovnyak, A. Brataas, G. E. W. Bauer, and B. I. Halperin, Nonlocal magnetization dynamics in ferromagnetic heterostructures, Rev. Mod. Phys. 77, 1375 (2005). [0pt] [3] S. E. Barnes and S. Maekawa, Generalization of Faraday's Law to Include Nonconservative Spin Forces Phys. Rev. Lett. 98, 246601 (2007); S. E. Barnes and S. Maekawa, Currents induced by domain wall motion in thin ferromagnetic wires. arXiv:cond-mat/ 0410021v1 (2004). [0pt] [4] S. E., Barnes, Spin motive forces, measurement, and spin-valves. J. Magn. Magn. Mat. 310, 2035-2037 (2007); S. E. Barnes, J. Ieda. J and S. Maekawa, Magnetic memory and current amplification devices using moving domain walls. Appl. Phys. Lett. 89, 122507 (2006). [0pt] [5] Pham-Nam Hai, Byung-Ho Yu

  4. Modélisation par éléments finis 3D du champ magnétostatique dans les enroulements des réactances cuirassées de grande puissance. Comparaison avec le calcul en 2D

    NASA Astrophysics Data System (ADS)

    Ngnegueu, Triomphant; Terme, Claude; Mailhot, Michel

    1993-03-01

    In this paper, the finite element method is applied for the computation of the magnetostatic field in the windings of a shell-form reactor. The modeling is carried out in 3D, using FLUX3D, a software developed at the Laboratoire d'Electrotechnique de Grenoble. The results are compared to those obtained in 2D. These calculation results are also compared to some test results. Dans cet article, nous décrivons une application de la méthode des éléments finis pour la modélisation du champ magnétostatique dans les enroulements d'une réactance cuirassée de grande puissance. La modélisation est conduite en 3D, en utilisant le logiciel FLUX3D. Les résultats du calcul sont comparés avec ceux obtenus en 2D. Quelques comparaisons sont aussi effectuées avec des résultats de mesure.

  5. High field (up to 140 kOe) angle dependent magneto transport of Bi2Te3 single crystals

    NASA Astrophysics Data System (ADS)

    Sultana, Rabia; Maheshwari, P. K.; Tiwari, Brajesh; Awana, V. P. S.

    2018-01-01

    We report the angle dependent high field (up to 140 kOe) magneto transport of Bi2Te3 single crystals, a well-known topological insulator. The crystals were grown from melt of constituent elements via solid state reaction route by self-flux method. Details of crystal growth along with their brief characterisation up to 5 Tesla applied field was reported by some of us recently (Sultana et al 2017 J. Magn. Magn. Mater. 428 213). The angle dependence of the magneto-resistance (MR) of Bi2Te3 follows the cos (θ) function i.e., MR is responsive, when the applied field is perpendicular (tilt angle θ = 0° and/or 180°) to the transport current. The low field (±10 kOe) MR showed the signatures of weak anti localisation character with typical ν-type cusp near origin at 5 K. Further, the MR is linear right up to highest applied field of 140 kOe. The large positive MR are observed up to high temperatures and are above 250% and 150% at 140 kOe in perpendicular fields at 50 K and 100 K respectively. Heat capacity C P(T) measurements revealed the value of Debye temperature (ѲD) to be 135 K. Angle resolved photoemission spectroscopy data clearly showed that the bulk Bi2Te3 single crystal consists of a single Dirac cone.

  6. The collagenic architecture of human dura mater.

    PubMed

    Protasoni, Marina; Sangiorgi, Simone; Cividini, Andrea; Culuvaris, Gloria Tiffany; Tomei, Giustino; Dell'Orbo, Carlo; Raspanti, Mario; Balbi, Sergio; Reguzzoni, Marcella

    2011-06-01

    Human dura mater is the most external meningeal sheet surrounding the CNS. It provides an efficient protection to intracranial structures and represents the most important site for CSF turnover. Its intrinsic architecture is made up of fibrous tissue including collagenic and elastic fibers that guarantee the maintenance of its biophysical features. The recent technical advances in the repair of dural defects have allowed for the creation of many synthetic and biological grafts. However, no detailed studies on the 3D microscopic disposition of collagenic fibers in dura mater are available. The authors report on the collagenic 3D architecture of normal dura mater highlighting the orientation, disposition in 3 dimensions, and shape of the collagen fibers with respect to the observed layer. Thirty-two dura mater specimens were collected during cranial decompressive surgical procedures, fixed in 2.5% Karnovsky solution, and digested in 1 N NaOH solution. After a routine procedure, the specimens were observed using a scanning electron microscope. The authors distinguished the following 5 layers in the fibrous dura mater of varying thicknesses, orientation, and structures: bone surface, external median, vascular, internal median, and arachnoid layers. The description of the ultrastructural 3D organization of the different layers of dura mater will give us more information for the creation of synthetic grafts that are as similar as possible to normal dura mater. This description will be also related to the study of the neoplastic invasion.

  7. 21 CFR 882.5975 - Human dura mater.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Human dura mater. 882.5975 Section 882.5975 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES NEUROLOGICAL DEVICES Neurological Therapeutic Devices § 882.5975 Human dura mater. (a...

  8. 21 CFR 882.5975 - Human dura mater.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... 21 Food and Drugs 8 2012-04-01 2012-04-01 false Human dura mater. 882.5975 Section 882.5975 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES NEUROLOGICAL DEVICES Neurological Therapeutic Devices § 882.5975 Human dura mater. (a...

  9. 21 CFR 882.5975 - Human dura mater.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... 21 Food and Drugs 8 2013-04-01 2013-04-01 false Human dura mater. 882.5975 Section 882.5975 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES NEUROLOGICAL DEVICES Neurological Therapeutic Devices § 882.5975 Human dura mater. (a...

  10. 21 CFR 882.5975 - Human dura mater.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Human dura mater. 882.5975 Section 882.5975 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES NEUROLOGICAL DEVICES Neurological Therapeutic Devices § 882.5975 Human dura mater. (a...

  11. 21 CFR 882.5975 - Human dura mater.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... 21 Food and Drugs 8 2014-04-01 2014-04-01 false Human dura mater. 882.5975 Section 882.5975 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES NEUROLOGICAL DEVICES Neurological Therapeutic Devices § 882.5975 Human dura mater. (a...

  12. Integration of Heterogeneous Bibliographic Information through Data Abstractions.

    DTIC Science & Technology

    1986-01-01

    11-12 [COMPENDEX] a) Electronics v 56 n 7 Apr 7 1983 p 155-157. b) IEEE Trans Magn v Mag-14 n 5 Sep 1978, INTERMAG (lnt Magn) Conf, I Florence, Italy ...developed a g0eograph.Cally distributed information systems as DOE/ PECaN . DOD/OROLS. NASA/RECON. CAS On-Line. OARC (France) and DECHEMA (West Germany

  13. Diffuse γ-ray emission from misaligned active galactic nuclei

    DOE PAGES

    Di Mauro, M.; Calore, F.; Donato, F.; ...

    2013-12-20

    Active galactic nuclei (AGNs) with jets seen at small viewing angles are the most luminous and abundant objects in the γ-ray sky. AGNs with jets misaligned along the line of sight appear fainter in the sky but are more numerous than the brighter blazars. Here, we calculate the diffuse γ-ray emission due to the population of misaligned AGNs (MAGNs) unresolved by the Large Area Telescope (LAT) on the Fermi Gamma-ray Space Telescope (Fermi). Furthermore, a correlation between the γ-ray luminosity and the radio-core luminosity is established and demonstrated to be physical by statistical tests, as well as compatible with uppermore » limits based on Fermi-LAT data for a large sample of radio-loud MAGNs. We constrain the derived γ-ray luminosity function by means of the source-count distribution of the radio galaxies detected by the Fermi-LAT. We finally calculate the diffuse γ-ray flux due to the whole MAGN population. These results demonstrate that MAGNs can contribute from 10% up to nearly the entire measured isotropic gamma-ray background. We evaluate a theoretical uncertainty on the flux of almost an order of magnitude.« less

  14. Control of rabbit dura mater optical properties with osmotical liquids

    NASA Astrophysics Data System (ADS)

    Yao, Lei; Cheng, Haiying; Luo, Qingming; Zhang, Wei; Zeng, Shaoqun; Tuchin, Valery V.

    2002-04-01

    An experimental study of controlling the optical properties of in vitro and in vivo rabbit dura mater with administration of osmotical agents, 40% glucose solution and glycerol, using video camera and spectrometer was presented. The preliminary results of experimental study of influence of osmotical liquids (glucose solutions, glycerol) on transmittance (in vitro) and reflectance (in vivo) spectra of rabbit dura mater were reported. The significant decreasing of the reflectance and increasing of the transmittance of dura mater under action of osmotical solutions were demonstrated. Experiments showed that administration of osmolytes to dura mater allowed for effective and temporary control of its optical characteristics, which made dura mater more transparent, increased the ability of light penetrating the tissue, and consequently improved the optical imaging depth. It is a significant study, which can improve penetration of optical imaging of cerebral function and acquire more information of the deep brain tissue.

  15. Titanium carbide and titania phases on Antarctic ice particles of probable extraterrrestrial origin

    NASA Technical Reports Server (NTRS)

    Zolensky, M. E.; Pun, A.; Thomas, K. L.

    1989-01-01

    Two unique titania-rich particles, found within ancient Antarctic ice have been discovered and characterized, and are believed to be of extraterrestrial origin. Both particles contain abundant submicron-sized crystals of Magneli phases (Ti(n)O(2n-1). In addition, one particle contains a core of TiC. Whereas the Magneli phases would have been stable in the early solar nebula, and so probably formed there, the TiC is more likely to have condensed in the cool, dusty, carbon-rich outer shell of a red giant star. It is suggested that both particles are interplanetary dust particles whose Magneli phases carry a record of the PO2-T conditions of the early solar nebula. It is further suggested that the TiC grain in particle 705 is remnant interstellar dust.

  16. A magneto-optic technique for studying magnetization reversal processes and anisotropies applied to Co/Cu/Co trilayer structures

    NASA Astrophysics Data System (ADS)

    Daboo, C.; Bland, J. A. C.; Hicken, R. J.; Ives, A. J. R.; Baird, M. J.; Walker, M. J.

    1993-05-01

    We report the magnetization reversal and magnetic anisotropy behavior of ultrathin Co/Cu(111)/Co (dCu=20 and 27 Å) trilayer structures prepared by MBE on a 500-Å Ge/GaAs(110) epilayer. We describe an arrangement in which the magnetization components parallel and perpendicular to the applied field are both determined from longitudinal MOKE measurements. For the samples examined, coherent rotation of the magnetization vector is observed when the magnetic field is applied along the hard in-plane anisotropy axis, with the magnitude of the magnetization vector constant and close to its bulk value. Results of micromagnetic calculations closely reproduce the observed parallel and perpendicular magnetization loops, and yield strong uniaxial magnetic anisotropies in both layers while the interlayer coupling appears to be absent or negligible in comparison with the anisotropy strengths. An absence of antiferromagnetic (AF) coupling has been observed previously [W. F. Egelhoff, Jr. and M. T. Kief, Phys. Rev. B 45, 7795 (1992)] in contrast to recent results, indicating that AF coupling [M. T. Johnson et al., Phys. Rev. Lett. 69, 969 (1992)] and GMR [D. Grieg et al., J. Magn. Magn. Mater. 110, L239 (1992)] can occur in Co/Cu(111)/Co structures grown by MBE, but these properties are sensitively dependent on growth conditions. The absence of coupling in our samples is attributed to the presence of a significant interface roughness induced by the Ge epilayer. The uniaxial anisotropies are assumed to arise from strain or defects induced in the film.

  17. Tailoring Mater-Bi properties by the use of a biowaste-derived additive

    NASA Astrophysics Data System (ADS)

    Cerruti, Pierfrancesco; Santagata, Gabriella; Gomez d'Ayala, Giovanna; Malinconico, Mario; Ambrogi, Veronica; Carfagna, Cosimo; Persico, Paola

    2010-06-01

    In this work, a polyphenol-containing extract from winery bio-waste (EP) has been used as additive to tailor Mater-Bi properties. EP was able to efficiently modulate both polymer processing and mechanical, thermal and biodegradation properties. EP decreased the melt viscosity, behaved as a Mater-Bi plasticizer and delayed the Mater-Bi crosslinking process occurring upon thermal aging. Finally, the biodisintegration rate of doped Mater-Bi decreased, thus indicating that EP interfered with the microbial digestion of the polymer films.

  18. Low-Cost, High-Throughput 3-D Pulmonary Imager Using Hyperpolarized Contrast Agents and Low-Field MRI

    DTIC Science & Technology

    2017-10-01

    Body MRI Experiments. Enc. Magn. Reson. 2007, DOI: 10.1002/9780470034590.emrstm0491. (59) Minard, K. R.; Wind , R. A. Solenoidal microcoil designPart II...Optimizing winding parameters for maximum signal-to-noise perform- ance. Concepts Magn. Reson. 2001, 13, 190−210. (60) Danieli, E.; Perlo, J...NMR spinner turbine was adjusted for the detection of the gas phase just above the liquid (Figure S2). Next, the displacement of HP propane from the

  19. Targeting MRS-Defined Dominant Intraprostatic Lesions with Inverse-Planned High Dose Rate Brachytherapy

    DTIC Science & Technology

    2011-06-01

    peaks [32]. Spectroscopic voxels were classified using the stan- dardized scoring system proposed by Jung et al. [33] where 1 = definitely normal, 2...prostate with flyback echo-pla- nar encoding. Magn Reson Imaging 2007; 25: 1288-1292. 30. Schricker AA, Pauly JM, Kurhanewicz J et al. Dualband spec...method for automatic quantifi- cation of 1-D Spectra with low signal to noise ratio. J Magn Reson 1987; 75: 229-243. 33. Jung JA, Coakley FV, Vigneron DB

  20. Charge storage in oxygen deficient phases of TiO2: defect Physics without defects.

    PubMed

    Padilha, A C M; Raebiger, H; Rocha, A R; Dalpian, G M

    2016-07-01

    Defects in semiconductors can exhibit multiple charge states, which can be used for charge storage applications. Here we consider such charge storage in a series of oxygen deficient phases of TiO2, known as Magnéli phases. These Magnéli phases (TinO2n-1) present well-defined crystalline structures, i.e., their deviation from stoichiometry is accommodated by changes in space group as opposed to point defects. We show that these phases exhibit intermediate bands with an electronic quadruple donor transitions akin to interstitial Ti defect levels in rutile TiO2. Thus, the Magnéli phases behave as if they contained a very large pseudo-defect density: ½ per formula unit TinO2n-1. Depending on the Fermi Energy the whole material will become charged. These crystals are natural charge storage materials with a storage capacity that rivals the best known supercapacitors.

  1. Spin-Torque Diode Effect in Magnetic Tunnel Junctions

    NASA Astrophysics Data System (ADS)

    Suzuki, Yoshishige

    2007-03-01

    Spin-injection magnetization switching (SIMS) technique [1] made it possible to control magnetization by a direct current. A discovery of spontaneous rf oscillation from CPP-GMR nano-pillars and a real time observation of the switching process have revealed essential amplification function of a precession in the magnetic nano-pillars under a direct current [2]. Beside of those progresses, developments of giant tunneling magneto-resistive (GTMR) effect using an MgO barrier [3] made it possible to utilize a very large resistance change according to the magnetization switching. In this talk, several attempts to utilize interplay between spin-torque and giant-TMR effect will be presented referring to a ``spin-torque diode effect'' [4] and other properties such like rf noise control and possible signal amplification using magnetic tunnel junctions (MTJs). [1] J. C. Slonczewski, J. Magn. Magn. Mater. 159, L1 (1996) , L. Berger, Phys. Rev. B 54, 9353 (1996), and E. B. Myers, et al., Science 285, 867 (1999). [2] S. I. Kiselev et al., Nature 425, 380 (2003), I. N. Krivorotov et al., Science, 307, 228 (2005). [3] W. Wulfhekel, et al. Appl. Phys. Lett. 78, 509--511 (2001), M. Bowen, et al. Appl. Phys. Lett. 79, 1655--1657 (2001), J. Faure-Vincent, et al. Appl. Phys. Lett. 82, 4507--4509 (2003), S. Yuasa, et al., Jpn. J. Appl. Phys. Part 2, 43, L588 (2004), S. Yuasa, et al., Nature Mat. 3, 868 (2004), S. S. P. Parkin et al., Nature Mat. 3, 862 (2004), and D. D. Djayaprawira et al., Appl. Phys. Lett. 86, 092502 (2005). [4] A. A. Tulapurkar, et al., Nature, 438, 339 (2005).

  2. Nuclear Magnetic Resonance Nondestructive Evaluation of Composite Materials

    DTIC Science & Technology

    1990-04-09

    Pat. Appl. EP 26265, 8 Apr 1981, 13 pp. (1981). 9. A. N. Garroway , J. Baum, M. G. Munowitz, and A. Pines, NMR Imaging in Solids by Multiple-Quantum...Resonance, J. Magn. Reson. 60(2), 337-41 (1984). 10. J. Baum, A. N. Garroway , M. Munowitz, and A. Pines, Multiple-Quantum NMR in Solids: Application to... Garroway , NMR Images of Solids, J. Magn. Reson. 66(3), 530-5 (1986). 28. J. B. Miller and A. N. Garroway , Removal of Static Field Inhomogeneity and

  3. Retraction Notice to ;Fabrication, electromagnetic characteristics of microwave absorbers containing Li0.35Zn0.3Fe2.35O4 micro-belts, nickel-coated carbon fibers; [J. Magn. Magn. Mater. 345 (2013) 249-254

    NASA Astrophysics Data System (ADS)

    Zhao, Bin; Wang, Qilei; Zhang, Cunrui

    2017-08-01

    This article has been retracted: please see Elsevier Policy on Article Withdrawal (http://www.elsevier.com/locate/withdrawalpolicy) This article has been retracted at the request of the Editor-in-Chief. The authors have plagiarized part of a paper that had already appeared in Ceram. Int., 39 (2013) 2317-2322, http://dx.doi.org/10.1016/j.ceramint.2012.08.079.

  4. Improvements in Diagnostic Accuracy with Quantitative Dynamic Contrast-Enhanced MRI

    DTIC Science & Technology

    2014-03-01

    values   With the fat B1 map it is now possible to obtain a B1 map for the whole field of view. To do this we have been testing software to...10.1002/ mrm .21120. 7. Nehrke K. On the steady-state properties of actual flip angle imaging (AFI). Magn. Reson. Med. 2009;61:84–92. doi: 10.1002/ mrm ...by bilateral dynamic contrast‐enhanced MRI: A sensitivity and specificity study. Magn. … 2008;59:747–54. doi: 10.1002/ mrm .21530. 11. Hylton N

  5. Mechanical and thermal properties of bacterial-cellulose-fibre-reinforced Mater-Bi(®) bionanocomposite.

    PubMed

    Nainggolan, Hamonangan; Gea, Saharman; Bilotti, Emiliano; Peijs, Ton; Hutagalung, Sabar D

    2013-01-01

    The effects of the addition of fibres of bacterial cellulose (FBC) to commercial starch of Mater-Bi(®) have been investigated. FBC produced by cultivating Acetobacter xylinum for 21 days in glucose-based medium were purified by sodium hydroxide 2.5 wt % and sodium hypochlorite 2.5 wt % overnight, consecutively. To obtain water-free BC nanofibres, the pellicles were freeze dried at a pressure of 130 mbar at a cooling rate of 10 °C min(-1). Both Mater-Bi and FBC were blended by using a mini twin-screw extruder at 160 °C for 10 min at a rotor speed of 50 rpm. Tensile tests were performed according to ASTM D638 to measure the Young's modulus, tensile strength and elongation at break. A field emission scanning electron microscope was used to observe the morphology at an accelerating voltage of 10 kV. The crystallinity (T c) and melting temperature (T m) were measured by DSC. Results showed a significant improvement in mechanical and thermal properties in accordance with the addition of FBC into Mater-Bi. FBC is easily incorporated in Mater-Bi matrix and produces homogeneous Mater-Bi/FBC composite. The crystallinity of the Mater-Bi/FBC composites decrease in relation to the increase in the volume fraction of FBC.

  6. Multiparametric magnetic resonance imaging findings of prostatic pure leiomyomas.

    PubMed

    Mussi, Thais Caldara; Costa, Yves Bohrer; Obara, Marcos Takeo; Queiroz, Marcos Roberto Gomes de; Garcia, Rodrigo Gobbo; Longo, José Antonio Domingos Cianciarulo; Lemos, Gustavo Caserta; Baroni, Ronaldo Hueb

    2016-01-01

    To describe the imaging findings of prostatic tumors nonadenocarcinoma on multiparametric magnetic resonance imaging. A total of 200 patients underwented multiparametric magnetic resonance imaging of the prostate for screening for prostate cancer, from August 2013 to September 2014, followed by biopsy with ultrasound/magnetic resonance imaging fusion. We found three pathologic proved cases of prostatic pure leiomyomas (0.02%) in our series and described the multiparametric magnetic resonance imaging features of these prostatic leiomyomas. The imaging findings had similar features to lesions with moderate or high suspicion for significant cancer (Likert 4 or 5) when localized both in the transitional zone or in the peripheral zone of the gland. Pure prostatic leiomyomas had imaging findings on multiparametric magnetic resonance imaging that mimicked usual adenocarcinomas on this test. Radiologists, urologists and pathologists must be aware of this entity and its imaging features. Descrever os achados de imagem de tumores prostáticos não adenocarcinoma na ressonância magnética multiparamétrica. Realizaram ressonância magnética multiparamétrica da próstata para detecção de câncer de próstata 200 pacientes de agosto de 2013 a setembro de 2014, seguida por biópsia com fusão de imagens de ultrassonografia/ressonância magnética. Encontramos três casos confirmados histologicamente de leiomiomas prostáticos puros (0,02%) em nossa casuística e descrevemos os achados da ressonância magnética multiparamétrica destes casos de leiomiomas. Os achados de imagem foram semelhantes aos de lesões com moderada ou alta suspeição para neoplasia clinicamente significante (Likert 4 ou 5) quando localizados na zona de transição ou zona periférica da próstata. Leiomiomas puros da próstata tiveram achados de imagem na ressonância magnética multiparamétrica que mimetizaram adenocarcinomas. Radiologistas, urologistas e patologistas devem estar cientes destas

  7. Magnetic Viruses: Utilizing Self-Assembly for Biomedical Applications

    NASA Astrophysics Data System (ADS)

    Hoffmann, Axel

    2006-03-01

    Magnetic nanoparticles coated with biochemical surfactants have emerged recently as an important component for enabling many biological and medical applications. We implemented a biotemplating approach to create such magnetic nanoparticles by utilizing native protein capsid shells derived in high yield from the T7 bacteriophage virus. The magnetic nanoparticles are grown via bio-mineralization reactions inside of hollowed-out capsids that retain their original chemical recognition properties. The resultant ``magnetic viruses'' are uniform in geometry, physical properties, and biochemical functionality. This makes these viruses ideally suited for many biomedical applications among which we investigated specifically a novel sensing scheme for target recognition based on Brownian relaxation. For this scheme we use the ac-susceptibility of the functionalized magnetic nanoparticles suspended in liquid. Upon binding the target of interest to the particles, their Brownian relaxation time is modified, which is readily detected by a change of the frequency dependence of the magnetic susceptibility. This scheme has several advantages; (i) it requires only one binding event for sensing; (ii) there is a useful signal both in the absence and presence of the target; (iii) the signal contains information about the size of the target besides the biochemical affinity; and (iv) since the binding modifies the magnetic susceptibility of the magnetic particles there is no need for removing unbound labels. C. Liu, S.-H. Chung, Q. Jin, A. Sutton, F. Yan, B. K. Kay, S. D. Bader, L. Makowski, and L. Chen, J. Magn. Magn. Mater, in press. S.H. Chung, A. Hoffmann, S. D. Bader, C. Liu, B. Kay, L. Makowski, and L. Chen, Appl. Phys. Lett. 85, 2971 (2004) ; S. H. Chung, A. Hoffmann, K. Guslienko, S. D. Bader, C. Liu, B. Kay, L. Makowski, and L. Chen, J. Appl. Phys. 97, 10R101 (2005).

  8. Time temperature transformation diagram for secondary crystal products of Co-based Co-Fe-B-Si-Nb-Mn soft magnetic nanocomposite

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    DeGeorge, V., E-mail: vdegeorge@cmu.edu; Zoghlin, E.; Keylin, V.

    2015-05-07

    Secondary crystallization is the subject of much investigation in magnetic amorphous and nanocomposites (MANCs) as it limits the long term and thermal stability of their operation in device applications, including power electronics, sensors, and electric motors. Secondary crystal products [Blazquez et al., Philos. Mag. Lett. 82(7), 409–417 (2002); Ohodnicki et al., Phys. Rev. B 78, 144414 (2008); Willard et al., Metall. Mater. Trans. A 38, 725 (2007)], nanostructure and crystallization kinetics [Hsiao et al., IEEE Trans. Magn. 38(5), 3039 (2002); McHenry et al., Scr. Mater. 48(7), 881 (2003)], and onset temperatures and activation energies [Ohodnicki et al., Acta. Mater. 57,more » 87 (2009); Long et al., J. Appl. Phys. 101, 09N114 (2007)] at constant heating have been reported for similar alloys. However, a time-temperature-transformation (TTT) diagram for isothermal crystallization, more typical of application environments, has not been reported in literature. Here, a TTT diagram for the Co based, Co-Fe-Si-Nb-B-Mn MANC system is presented, along with a method for determining such. The method accounts for the presence of primary crystal phases and yields crystal fraction of secondary phase(s) by using a novel four stage heating profile. The diagram, affirmed by Kissinger activation energy analysis, reports thermal stability of the MANC for millennia at conventional device operating temperatures, and stability limits less than a minute at elevated temperatures. Both extremes are necessary to be able to avoid secondary crystalline products and establish operating limits for this mechanically attractive, high induction soft magnetic nanocomposite.« less

  9. Microstructure evolution characteristics induced by oxygen vacancy generation in anatase TiO2 based resistive switching devices

    NASA Astrophysics Data System (ADS)

    Liu, Chen; Gao, Bin; Huang, Peng; Kang, Jinfeng

    2017-03-01

    In this work, first principle calculations are employed to study the microstructure characteristics of the anatase TiO2 resistive switching material associated with the generation of oxygen vacancy (V o) based nanofilaments during the switching process. The calculations indicate that both the magnéli phase Ti4O7 and V o-defect phase of anatase TiO2 may be formed with the generation of oxygen vacancies during the forming and SET processes. Based on the calculations, a new physical insight is proposed to clarify the microstructure evolution characteristics of the anatase TiO2 resistive switching material and the correlation with resistive switching behaviors. During the forming or SET process, the anatase TiO2 is first excited to a transition state with the generation of oxygen vacancies, then fully relaxes to a stable V o-defect state. This V o-defect state may either recover to the original state with the recombination of the oxygen vacancies, which causes the reversible resistive switching behavior, or further transform to a much more stable state—the magnéli phase Ti4O7, through a phase transition process with the generation of many more oxygen vacancies. The phase transition from V o- defective anatase phase to magnéli phase Ti4O7 causes the failure of the resistive switching due to the significantly reduced possibility of the reversible phase transition from the magnéli phase to the anatase phase, compared with the possibility of the recombination from the V o-defective anatase.

  10. Magnetic Turbulence in Clusters of Galaxies

    DTIC Science & Technology

    2009-01-01

    plasmas que nos permiten confrontar conceptos teóricos del origen del campo magnético con observaciones detalladas. La turbulencia magnética en...GALAXIES T. A. Enßlin,1 T. Clarke,2 C. Vogt,3 A. Waelkens,1 A. A. Schekochihin4 RESUMEN Los cúmulos de galaxias son grandes laboratorios de turbulencia en...éstos cúmulos puede ser estudiada a través de la emisión radio-sincrotrón del medio intra-cúmulo en forma de rélicas y halos de los cúmulos. El

  11. Size Effects in Epitaxial Films of Magnetite

    DTIC Science & Technology

    2002-06-03

    van Eemeren , J. aan de Stegge, 1727. WJ.M. de Jonge, Surf. Sci. 373 (1997) 85. [38] J.L. Dormann, T. Merceron, P. Renaudin, VA.M. Brabers, J. [20] S.A...Metals and Semiconductors, Trans Tech, Switzerland, 1994, p. __221. [4] G.A. Prinz, Phys. Today 48 (1995) 58. 100 - [5] P.J. van der Zaag. P.J.H...Bloemen. J.M. Gaines, R.M. Wolf, -10 -8 -6 -4 -2 0 2 4 6 8 10 P.A.A. van der Heijden, R.J.M. van de Veerdonk, W.J.M. velocity [mm/s] de Jonge, J. Magn. Magn

  12. Measurements of Hk and Ms in thin magnetic films by the angular dependence of the planar Hall effect

    NASA Astrophysics Data System (ADS)

    Vatskicheva, M.; Vatskichev, L.

    1987-11-01

    It is shown that the angular dependences of the planar Hall effect measured with infinite magnetic field and with magnetic field H⩾ Hk have an intersection point and this fact is enough for measuring the anisotropy field Hk applying the method presented by Pastor, Ferreiro and Torres in J. Magn. Magn. Mat. 53 (1986) 349, 62 (1986) 101. The scaling of the Hall tension U proportional to M2s in mV/Am -1 gives a possibility for calculating the Ms-values of the films. These assumptions are verified for NiFe- and NiFeGe films with a uniaxial magnetic anisotropy.

  13. Mater semper incertus est: who's your mummy?

    PubMed

    D'alton-Harrison, Rita

    2014-01-01

    In English law, the legal term for father has been given a broad definition but the definition of mother remains rooted in biology with the Roman law principle mater semper certa est (the mother is always certain) remaining the norm. However, motherhood may be acquired through giving birth to a child, by donation of gametes or by caring and nurturing a child so that the identity of the mother is no longer certain particularly in the case of surrogacy arrangements. While the law in the UK may automatically recognise the parental status of a commissioning father in a traditional surrogacy arrangement, the parental status of the commissioning mother is not automatically recognised in either a traditional or a gestational surrogacy arrangement. Thus the maxim mater est quam gestation demonstrat (meaning the mother is demonstrated by gestation) is also not approached consistently in the legal interpretation of parentage or motherhood in surrogacy as against other assisted reproduction methods. This raises questions about the extent to which motherhood should be affected by the method of reproduction and whether the sociological and philosophical concept of motherhood should, in the case of surrogacy, give rise to a new principle of 'mater semper incertus est' (the mother is uncertain). This article will argue that the time has come to move away from a legal definition of 'mother' that is based on biology to one that recognises the different forms of motherhood. © The Author [2014]. Published by Oxford University Press; all rights reserved. For Permissions, please email: journals.permissions@oup.com.

  14. Effect of quercetin on plasma extravasation in rat CNS and dura mater by ACE and NEP inhibition.

    PubMed

    Cyrino, Luiz A R; Cardoso, Ronie C F; Hackl, Luciane P N; Nicolau, Mauro

    2002-09-01

    The effects of quercetin on substance P-induced plasma protein extravasation (PE) in the rat dura mater, cerebellum, olfactory bulb and cortex and also its modulation by endopeptidases, angiotensin-converting enzyme (ACE) and neutral endopeptidase (NEP) were studied. PE was assessed by photometric measurement of extravasated Evans blue. Substance P (SP) and NEP or ACE inhibitors increased the PE in dura mater. Pretreatment with captopril or phosphoramidon potentiated PE induced by SP in the dura mater and cerebellum, respectively. Quercetin increased the PE in the dura mater, cerebellum and cortex. Further results suggested that the PE induced by SP in the dura mater was enhanced by pretreatment with quercetin, similar to that observed with selective peptidase inhibitors. Quercetin-stimulated extravasation in all tissues was abolished by NK-1 receptor blockade. These results suggest that quercetin increases PE in the dura mater and CNS tissues by inhibiting NEP and/or ACE, showing that the effect induced in the dura mater, cerebellum and cortex occurs through endogenous SP accumulation. Copyright 2002 John Wiley & Sons, Ltd.

  15. Modelo semi-empírico de protuberancia solar a partir del diagnóstico de densidades

    NASA Astrophysics Data System (ADS)

    Cirigliano, D.; Vial, J. C.; Rovira, M.

    A partir de la observación del espectro del quintuplete de C III alrededor de 1175 Å, se ha realizado el diagnóstico de la densidad y presión electrónica, basado en el cálculo del cociente de las intensidades observadas. Una vez establecida la densidad electrónica, y con el cálculo de las velocidades Doppler, hemos investigado el flujo de masa en la protuberancia en función de la temperatura. Estableciendo como hipótesis la conservación del número de partículas que ingresan y salen del cuerpo de la protuberancia, se investiga la variación del área de un tubo de flujo semi-empírico en función de la temperatura. A partir de dicho diagnóstico, se examina el comportamiento del radio del tubo magnético en función de la temperatura, los que dan cuenta de la abertura de las líneas de campo magnético que confinan el plasma y de la divergencia del campo magnético en diferentes alturas de la atmósfera solar.

  16. Autoantibody response against NALP5/MATER in primary ovarian insufficiency and in autoimmune Addison's disease.

    PubMed

    Brozzetti, Annalisa; Alimohammadi, Mohammad; Morelli, Silvia; Minarelli, Viviana; Hallgren, Åsa; Giordano, Roberta; De Bellis, Annamaria; Perniola, Roberto; Kämpe, Olle; Falorni, Alberto

    2015-05-01

    NACHT leucine-rich-repeat protein 5 (NALP5)/maternal antigen that embryo requires (MATER) is an autoantigen in hypoparathyroidism associated with autoimmune polyendocrine syndrome type 1 (APS1) but is also expressed in the ovary. Mater is an autoantigen in experimental autoimmune oophoritis. The objectives of the study were to determine the frequency of NALP5/MATER autoantibodies (NALP5/MATER-Ab) in women with premature ovarian insufficiency (POI) and in patients with autoimmune Addison's disease (AAD) and to evaluate whether inhibin chains are a target for autoantibodies in POI. Autoantibodies against NALP5/MATER and inhibin chains-α and -βA were determined by radiobinding assays in 172 patients with AAD without clinical signs of gonadal insufficiency, 41 women with both AAD and autoimmune POI [steroidogenic cell autoimmune POI (SCA-POI)], 119 women with idiopathic POI, 19 patients with APS1, and 211 healthy control subjects. NALP5/MATER-Ab were detected in 11 of 19 (58%) sera from APS1 patients, 12 of 172 (7%) AAD sera, 5 of 41 (12%) SCA-POI sera, 0 of 119 idiopathic POI sera and 1 of 211 healthy control sera (P < .001). None of 160 POI sera, including 41 sera from women with SCA-POI and 119 women with idiopathic POI, and none of 211 healthy control sera were positive for inhibin chain-α/βA autoantibodies. NALP5/MATER-Ab are associated with hypoparathyroidism in APS1 but are present also in patients with AAD and in women with SCA-POI without hypoparathyroidism. Inhibin chains do not appear to be likely candidate targets of autoantibodies in human POI.

  17. 76 FR 36993 - Medical Devices; Neurological Devices; Clarification of Classification for Human Dura Mater...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-06-24

    ...; Clarification of Classification for Human Dura Mater; Technical Amendment AGENCY: Food and Drug Administration... amending the device regulations to clarify the applicability of the device classification for human dura..., human dura mater is now defined under 21 CFR 1271.3(d) as a HCT/P. As such, it is regulated under...

  18. Mater Academy Charter Middle School: Consistent Expectations

    ERIC Educational Resources Information Center

    Principal Leadership, 2010

    2010-01-01

    Mater Academy Charter Middle/High School is located in what was once a big box store in a commercial and industrial area of Hialeah Gardens, FL. The same energy that transformed a vacant store into a thriving campus for a grades 6-12 school is apparent in every classroom. Even the mayor of Hialeah Gardens credits the school with helping to…

  19. Modélisation macroscopique des milieux stratifiés conducteurs

    NASA Astrophysics Data System (ADS)

    Matagne, E.; Conard, J. Ph.

    1997-11-01

    Many laminated structures are recognised in Electrotechnics : magnetic cores, flat conductors windings, slotted surfaces... These structures exhibit macroscopic properties, as magnetic than electric ones. This paper shows how these characteristics can be obtained by homogenisation. It deals with linear materials but taking into account the effect of eddy currents, as well on the macroscopic magnetic permeability as on the macroscopic electric conductivity, which become then complex numbers. An example of use of the macroscopic properties is provided. On peut identifier en électrotechnique de nombreuses structures stratifiées: noyaux magnétiques, bobinages formés de conducteurs plats, surfaces encochées... Ces structures présentent des propriétés macroscopiques tant magnétiques qu'électriques. Cet article montre comment ces caractéristiques peuvent être obtenues par homogénéisation. Il se limite au cas de matériaux linéaires mais en prenant en compte l'effet des courants de Foucault aussi bien sur la perméabilité magnétique macroscopique que sur la conductivité électrique macroscopique, grandeurs qui deviennent alors des nombres complexes. Un exemple d'utilisation des caractéristiques macroscopiques est fourni.

  20. Perfil de temperatura dos funis magnetosféricos de estrelas T Tauri com aquecimento alfvênico

    NASA Astrophysics Data System (ADS)

    Vasconcelos, M. J.

    2003-08-01

    Estrelas T Tauri Clássicas são objetos jovens circundados por discos de gás e poeira e que apresentam uma intensa atividade magnética. Seu espectro mostra linhas de emissão alargadas que são razoavelmente reproduzidas nos modelos de acresção magnetosférica. No entanto, o perfil de temperatura dos funis magnéticos é desconhecido. Aquecimento magnético compressional e difusão ambipolar foram considerados para estas estruturas, porém as temperaturas obtidas não são suficientes para explicar as observações. Neste trabalho, examinamos o aquecimento gerado pelo amortecimento de ondas Alfvén através de quatro mecanismos, os amortecimentos não-linear, turbulento, viscoso-resistivo e colisional como função da freqüência da onda. Inicialmente, a temperatura é ajustada para reproduzir as observações e o grau de turbulência requerido para que o mecanismo seja viável é calculado. Os resultados mostram que este é compatível com os dados observacionais. Apresentam-se, também, resultados preliminares do cálculo auto-consistente do perfil de temperatura dos funis, levando-se em conta fontes de aquecimento Alfvênica e fontes de resfriamento.

  1. MATER protein expression and intracellular localization throughout folliculogenesis and preimplantation embryo development in the bovine

    PubMed Central

    Pennetier, Sophie; Perreau, Christine; Uzbekova, Svetlana; Thélie, Aurore; Delaleu, Bernadette; Mermillod, Pascal; Dalbiès-Tran, Rozenn

    2006-01-01

    Background Mater (Maternal Antigen that Embryos Require), also known as Nalp5 (NACHT, leucine rich repeat and PYD containing 5), is an oocyte-specific maternal effect gene required for early embryonic development beyond the two-cell stage in mouse. We previously characterized the bovine orthologue MATER as an oocyte marker gene in cattle, and this gene was recently assigned to a QTL region for reproductive traits. Results Here we have analyzed gene expression during folliculogenesis and preimplantation embryo development. In situ hybridization and immunohistochemistry on bovine ovarian section revealed that both the transcript and protein are restricted to the oocyte from primary follicles onwards, and accumulate in the oocyte cytoplasm during follicle growth. In immature oocytes, cytoplasmic, and more precisely cytosolic localization of MATER was confirmed by immunohistochemistry coupled with confocal microscopy and immunogold electron microscopy. By real-time PCR, MATER messenger RNA was observed to decrease strongly during maturation, and progressively during the embryo cleavage stages; it was hardly detected in morulae and blastocysts. The protein persisted after fertilization up until the blastocyst stage, and was mostly degraded after hatching. A similar predominantly cytoplasmic localization was observed in blastomeres from embryos up to 8-cells, with an apparent concentration near the nuclear membrane. Conclusion Altogether, these expression patterns are consistent with bovine MATER protein being an oocyte specific maternal effect factor as in mouse. PMID:16753072

  2. Interaction of micron and nano-sized particles with cells of the dura mater

    PubMed Central

    Papageorgiou, Iraklis; Marsh, Rainy; Tipper, Joanne L; Hall, Richard M; Fisher, John; Ingham, Eileen

    2014-01-01

    Intervertebral total disc replacements (TDR) are used in the treatment of degenerative spinal disc disease. There are, however, concerns that they may be subject to long-term failure due to wear. The adverse effects of TDR wear have the potential to manifest in the dura mater and surrounding tissues. The aim of this study was to investigate the physiological structure of the dura mater, isolate the resident dural epithelial and stromal cells and analyse the capacity of these cells to internalise model polymer particles. The porcine dura mater was a collagen-rich structure encompassing regularly arranged fibroblastic cells within an outermost epithelial cell layer. The isolated dural epithelial cells had endothelial cell characteristics (positive for von Willebrand factor, CD31, E-cadherin and desmoplakin) and barrier functionality whereas the fibroblastic cells were positive for collagen I and III, tenascin and actin. The capacity of the dural cells to take up model particles was dependent on particle size. Nanometer sized particles readily penetrated both types of cells. However, dural fibroblasts engulfed micron-sized particles at a much higher rate than dural epithelial cells. The study suggested that dural epithelial cells may offer some barrier to the penetration of micron-sized particles but not nanometer sized particles. © 2014 The Authors. Journal of Biomedical Materials Research Part B: Applied Biomaterials Published by Wiley Periodicals, Inc. J Biomed Mater Res Part B: Appl Biomater, 102B: 1496–1505, 2014. PMID:24604838

  3. 1997 Leonid Shower From Space

    NASA Technical Reports Server (NTRS)

    Jenniskens, Peter; Nugent, David; Murthy, Jayant; Tedesco, Ed; DeVincenzi, Donal L. (Technical Monitor)

    2000-01-01

    In November 1997, the Midcourse Space Experiment satellite (MSX) was deployed to observe the Leonid shower from space. The shower lived up to expectations, with abundant bright fireballs. Twenty-nine meteors were detected by a wide-angle, visible wavelength, camera near the limb of the Earth in a 48-minute interval, and three meteors by the narrow field camera. This amounts to a meteoroid influx of 5.5 +/- 0.6 10(exp -5)/sq km hr for masses greater than 0.3 gram. The limiting magnitude for limb observations of Leonid meteors was measured at M(sub v) = -1.5 magn The Leonid shower magnitude population index was 1.6 +/- 0.2 down to M(sub v) = -7 magn., with no sign of an upper mass cut-off.

  4. Evidence for CGRP re-uptake in rat dura mater encephali

    PubMed Central

    Gupta, Saurabh; Amrutkar, Dipak Vasantrao; Mataji, Aydin; Salmasi, Hassan; Hay-Schmidt, Anders; Sheykhzade, Majid; Messlinger, Karl; Olesen, Jes; Jansen-Olesen, Inger

    2010-01-01

    BACKGROUND AND PURPOSE Calcitonin gene-related peptide (CGRP) is widely distributed in the trigeminovascular system and released from sensory fibres of the cranial dura mater upon noxious stimulation. Such release may be a mechanism underlying migraine headache. Based on data from guinea pig basilar artery preparations, we have here studied CGRP release and uptake in an organ preparation of the hemisected rat skull. EXPERIMENTAL APPROACH CGRP release from the cranial dura was quantified by a commercial enzyme-linked immunoassay. CGRP was depleted using repetitive challenges of capsaicin. After incubating the tissue with CGRP for 20 min and extensive washing, another capsaicin challenge was performed. Immunohistochemistry was used to visualize CGRP immunofluorescence in dural nerve fibres. KEY RESULTS Capsaicin-induced CGRP release was attenuated by the transient receptor potential vanilloid receptor type I antagonist capsazepine or by Ca2+-free solutions. After the CGRP-depleted preparation had been exposed to exogenous CGRP, capsaicin-induced CGRP release was increased compared to the challenge just prior to incubation. CGRP uptake was not influenced by Ca2+-free solutions. Olcegepant and CGRP8–37 (CGRP receptor antagonists) did not affect uptake of CGRP. However, a monoclonal CGRP-binding antibody decreased CGRP uptake significantly. Release of CGRP after incubation was attenuated by Ca2+-free solutions and by capsazepine. Immunohistochemical assays indicated a weak trend towards CGRP uptake in rat dura mater. CONCLUSION AND IMPLICATIONS We have presented evidence for CGRP uptake in nerves and its re-release in rat dura mater. This may have implications for the pathophysiology and treatment of migraine. PMID:20804493

  5. Investigation on the oxidation behavior of AlCrVxN thin films by means of synchrotron radiation and influence on the high temperature friction

    NASA Astrophysics Data System (ADS)

    Tillmann, Wolfgang; Kokalj, David; Stangier, Dominic; Paulus, Michael; Sternemann, Christian; Tolan, Metin

    2018-01-01

    Friction minimization is an important topic which is pursued in research and industry. In addition to the use of lubricants, friction-reducing oxide phases can be utilized which occur during. These oxides are called Magnéli phases and especially vanadium oxides exhibit good friction reducing properties. Thereby, the lubrication effect can be traced back to oxygen deficiencies. AlCrN thin films are being used as coatings for tools which have to withstand high temperatures. A further improvement of AlCrN thin films concerning their friction properties is possible by incorporation of vanadium. This study analyzes the temperature dependent oxidation behavior of magnetron sputtered AlCrVN thin films with different vanadium contents up to 13.5 at.-% by means of X-ray diffraction and X-ray absorption near-edge spectroscopy. Up to 400 °C the coatings show no oxidation. A higher temperature of 700 °C leads to an oxidation and formation of Magnéli phases of the coatings with vanadium contents above 10.7 at.-%. Friction coefficients, measured by ball-on-disk test are correlated with the oxide formation in order to figure out the effect of vanadium oxides. At 700 °C a decrease of the friction coefficient with increasing vanadium content can be observed, due to the formation of VO2, V2O3 and the Magnéli phase V4O7.

  6. A Three-Component Model for Magnetization Transfer. Solution by Projection-Operator Technique, and Application to Cartilage

    NASA Astrophysics Data System (ADS)

    Adler, Ronald S.; Swanson, Scott D.; Yeung, Hong N.

    1996-01-01

    A projection-operator technique is applied to a general three-component model for magnetization transfer, extending our previous two-component model [R. S. Adler and H. N. Yeung,J. Magn. Reson. A104,321 (1993), and H. N. Yeung, R. S. Adler, and S. D. Swanson,J. Magn. Reson. A106,37 (1994)]. The PO technique provides an elegant means of deriving a simple, effective rate equation in which there is natural separation of relaxation and source terms and allows incorporation of Redfield-Provotorov theory without any additional assumptions or restrictive conditions. The PO technique is extended to incorporate more general, multicomponent models. The three-component model is used to fit experimental data from samples of human hyaline cartilage and fibrocartilage. The fits of the three-component model are compared to the fits of the two-component model.

  7. Neutron Depolarization in Superconductors

    NASA Astrophysics Data System (ADS)

    Zhuchenko, N. K.

    1995-04-01

    The dependences of neutron depolarization on applied magnetic field are deduced along the magnetization hysteresis loop in terms of the Bean model of the critical state. The depolarization in uniaxial superconductors with the reversible magnetization, including uniaxial magnetic superconductors, is also considered. A strong depolarization is expected if the neutrons travel along the vortex lines. On calcule la dépendance en champ magnétique de la dépolarisation des neutrons le long du cycle d'hystérésis en termes du modèle critique de Bean. On considère aussi la dépolarisation dans les supraconducteurs uniaxiaux en fonction de l'aimantation réversible, y compris pour les supraconducteurs magnétiques. On attend une forte dépolarisation si les neutrons se propagent le long des vortex.

  8. Single immunization with a suboptimal antigen dose encapsulated into polyanhydride microparticles promotes high titer and avid antibody responses

    USDA-ARS?s Scientific Manuscript database

    Microparticle adjuvants based on biodegradable polyanhydrides were used to provide controlled delivery of a model antigen, ovalbumin (Ova), to mice. Ova was encapsulated into two different polyanhydride microparticle formulations to evaluate the influence of polymer chemistry on the nature and magn...

  9. ANALYSIS OF THE STRUCTURE OF MAGNETIC FIELDS THAT INDUCED INHIBITION OF STIMULATED NEURITE OUTGROWTH

    EPA Science Inventory

    The important experiments showing nonlinear amplitude dependences of the neurite outgrowth in pheochromocytoma nerve cells due to ELF magnetic field exposure had been carried out in a nonuniform ac magnetic field. The nonuniformity entailed larger than expected variances in magne...

  10. THE EFFECTS OF SCALE, DISTANCE AND TIME ON DRINKING WATER SYSTEMS RESEARCH

    EPA Science Inventory

    This presentation introduces and describes many components related to what generates and/or controls the concentrations of metals and other constituents in drinking water. Emphasis is placed on ways in which sampling protocol affects apparent levels of constituents, and the magn...

  11. Safety of High Speed Guided Ground Transportation Systems - An Overview of Biological Effects and Mechanisms Relevant to EMF Exposures from Mass Transit and Electric Rail Systems

    DOT National Transportation Integrated Search

    1993-08-01

    The U.S. has implemented a national initiative to develop maglev (magnetic levitation) and other high-speed rail (HSR) : systems. There are concerns for potential adverse health effects of the Extremely Lou Frequency (3-3,000 Hz) electric : and magne...

  12. A Meteorite Dropping Superbolide from the Catastrophycally Disrupted Comet C1919Q2 Metcalf: A Pathway for Meteorites from Jupiter Family Comets

    NASA Astrophysics Data System (ADS)

    Trigo-Rodríguez, J. M.; Madiedo, J. M.; Williams, I. P.; Castro-Tirado, A. J.; Llorca, J.; Vítek, S.; Jelínek, M.

    2009-03-01

    A meter-sized meteoroid probably produced during the disintegration of comet C1919Q2 Metcalf was observed producing a -18 magn. bolide (MNRAS, in press).The progenitor meteoroid was sufficiently large and of high enough tensile strength to produce meteorites.

  13. Detecção da fase impulsiva de uma explosão solar gigante até 405 GHz

    NASA Astrophysics Data System (ADS)

    Raulin, J.-P.; Makhmutov, V.; Kaufmann, P.; Pacini, A. A.; Luethi, T.; Hudson, H. S.; Gary, D. E.; Yoshimori, M.

    2003-08-01

    A explosão ocorrida no dia 25/08/2001 foi uma das mais intensas do presente ciclo solar em ondas de rádio de altas frequências. Foram medidas em ondas milimétricas e submilimétricas, aproximadamente, 105 e vários milhares de unidades de fluxo solar, respectivamente. Apresentamos um estudo deste evento em múltiplas frequências, desde microondas (1GHz), até ondas submilimétricas (405 GHz) detectadas pelo Telescópio Solar para ondas Submilimétricas (SST). Esta base de dados foi complementada utilizando-se o experimento Yohkoh, incluindo a emissão em raios-X duros e raios-g (até 100 MeV), e imagens em raios-X moles da região ativa envolvida. Enfocamos e discutimos principalmente os seguintes aspectos da fase impulsiva do evento: (i) as implicações deduzidas do espectro eletromagnético, obtido pela primeira vez até 405 GHz; (ii) a dinâmica da região ativa. Os resultados mostram que para explicar o espectro rádio observado, são necessários entre 3.5×1037 e 1.5×1039 elétrons acelerados acima de 20 keV em uma região de campo magnético entre 300 e 800 Gauss. A estimativa do fluxo de fótons que seria produzido por estes elétrons, mostra que grande parte deles não precipitou na baixa atmosfera. A evolução temporal da emissão em raios-X moles revela que a configuração magnética da região ativa foi muito dinâmica durante a fase impulsiva da explosão. Em particular, mostramos que a produção dos elétrons altamente energéticos foi iniciada junto com a aparição, na baixa coroa solar, de um novo sistema compacto de estruturas magnéticas. Este fato sugere que os locais de aceleração estão localizados na baixa atmosfera do Sol, como resultado da interação entre o novo sistema compacto e o campo magnético ambiente da região ativa.

  14. ACUTE BEHAVORIAL EFFECTS FROM EXPOSURE TO TWO-STROKE ENGINE EXHAUST

    EPA Science Inventory

    Benefits of changing from two-stroke to four-stroke engines (and other remedial requirements) can be evaluated (monetized) from the standpoint of acute behavioral effects of human exposure to exhaust from these engines. The monetization process depends upon estimates of the magn...

  15. Correlation of Mechanical Properties in Bulk Metallic Glasses with 27Al NMR Characteristics

    DTIC Science & Technology

    2011-12-01

    recycle delay of 300 ms. Magnetization measurements were conducted at room temperature using a Quantum Design SQUID magne- tometer. The magnetization of...Gangopadhyay A K, et al. First X-ray scattering studies on electrostatically levitated metallic liquids: Demonstrated influence of local icosahedral

  16. Interaction of micron and nano-sized particles with cells of the dura mater.

    PubMed

    Papageorgiou, Iraklis; Marsh, Rainy; Tipper, Joanne L; Hall, Richard M; Fisher, John; Ingham, Eileen

    2014-10-01

    Intervertebral total disc replacements (TDR) are used in the treatment of degenerative spinal disc disease. There are, however, concerns that they may be subject to long-term failure due to wear. The adverse effects of TDR wear have the potential to manifest in the dura mater and surrounding tissues. The aim of this study was to investigate the physiological structure of the dura mater, isolate the resident dural epithelial and stromal cells and analyse the capacity of these cells to internalise model polymer particles. The porcine dura mater was a collagen-rich structure encompassing regularly arranged fibroblastic cells within an outermost epithelial cell layer. The isolated dural epithelial cells had endothelial cell characteristics (positive for von Willebrand factor, CD31, E-cadherin and desmoplakin) and barrier functionality whereas the fibroblastic cells were positive for collagen I and III, tenascin and actin. The capacity of the dural cells to take up model particles was dependent on particle size. Nanometer sized particles readily penetrated both types of cells. However, dural fibroblasts engulfed micron-sized particles at a much higher rate than dural epithelial cells. The study suggested that dural epithelial cells may offer some barrier to the penetration of micron-sized particles but not nanometer sized particles. © 2014 The Authors. Journal of Biomedical Materials Research Part B: Applied Biomaterials Published by Wiley Periodicals, Inc.

  17. The spinal cord dura mater reaction to nitinol and titanium alloy particles: a 1-year study in rabbits

    PubMed Central

    Rhalmi, Souad; Charette, Sylvie; Assad, Michel; Coillard, Christine

    2007-01-01

    This investigation was undertaken to simulate in an animal model the particles released from a porous nitinol interbody fusion device and to evaluate its consequences on the dura mater, spinal cord and nerve roots, lymph nodes (abdominal para-aortic), and organs (kidneys, spleen, pancreas, liver, and lungs). Our objective was to evaluate the compatibility of the nitinol particles with the dura mater in comparison with titanium alloy. In spite of the great use of metallic devices in spine surgery, the proximity of the spinal cord to the devices raised concerns about the effect of the metal debris that might be released onto the neural tissue. Forty-five New Zealand white female rabbits were divided into three groups: nitinol (treated: N = 4 per implantation period), titanium (treated: N = 4 per implantation period), and sham rabbits (control: N = 1 per observation period). The nitinol and titanium alloy particles were implanted in the spinal canal on the dura mater at the lumbar level L2–L3. The rabbits were sacrificed at 1, 4, 12, 26, and 52 weeks. Histologic sections from the regional lymph nodes, organs, from remote and implantation sites, were analyzed for any abnormalities and inflammation. Regardless of the implantation time, both nitinol and titanium particles remained at the implantation site and clung to the spinal cord lining soft tissue of the dura mater. The inflammation was limited to the epidural space around the particles and then reduced from acute to mild chronic during the follow-up. The dura mater, sub-dural space, nerve roots, and the spinal cord were free of reaction. No particles or abnormalities were found either in the lymph nodes or in the organs. In contact with the dura, the nitinol elicits an inflammatory response similar to that of titanium. The tolerance of nitinol by a sensitive tissue such as the dura mater during the span of 1 year of implantation demonstrated the safety of nitinol and its potential use as an intervertebral

  18. Noble internal transport barriers and radial subdiffusion of toroidal magnetic lines

    NASA Astrophysics Data System (ADS)

    Misguich, J. H.; Reuss, J.-D.; Constantinescu, D.; Steinbrecher, G.; Vlad, M.; Spineanu, F.; Weyssow, B.; Balescu, R.

    2003-11-01

    large number of trajectories, representing the evolution of a bunch of magnetic lines, indicate that the flux variable psi asymptotically grows in a diffusive manner as (L2t) with a L2 scaling as expected, but that the average radial position rm(t) asymptotically grows as (L2t)^{1/4} while the mean square displacement around this average radius asymptotically grows in a subdiffusive manner as (L2t)^{1/2}. This result shows the slower dispersion in the present incomplete chaotic regime, which is different from the usual quasilinear diffusion in completely chaotic situations. For physical times t_{\\varphi } of the order of the escape time defined by xm(t_{\\varphi })sim 1, the motion appears to be superdiffusive, however, but less dangerous than the generally admitted quasi-linear diffusion. The orders of magnitude of the relevant times in Tore Supra are finally discussed. Barrières internes de transport " nobles " et sous-diffusion radiale des lignes magnétiques toroïdales Les barrières internes de transport observées dans les tokamaks sont décrites ici dans une approche purement magnétique. Le mouvement des lignes magnétiques en géométrie toroïdale avec brisure des surfaces magnétiques est étudié à partir d'une application hamiltonienne "tokamap" développée précédemment en situation de chaos incomplet, et dans laquelle le "temps" est représenté par la coordonnée toroïdale. Cette application reproduit de façon réaliste les principales caractéristiques d'un tokamak, pour un profil donné du facteur de sécurité q, et en terme d'un seul paramètre L représentant l'amplitude de la perturbation magnétique. On obtient des résultats nouveaux concernant le déplacement de Shafranov en fonction de L. L'espace des phases (psi,θ) du "tokamap" décrit la section poloïdale des trajectoires des lignes, où psisim r^2 est le flux toroïdal caractérisant les surfaces magnétiques (proportionnel au carré du rayon r de cette surface). Pour de faibles

  19. Réalisation d'écrans magnétiques supraconducteurs

    NASA Astrophysics Data System (ADS)

    Lainée, F.; Kormann, R.

    1992-02-01

    Low fields and low frequency shielding properties of YBCO magnetic shields are measured at 77 K. They compare favourably with shielding properties of mumetal shields. Therefore high-T_c superconducting magnetic shields can already be used to shield small volumes. The case of magnetic shields for large volumes is also discussed. Nous mesurons à 77K les caractéristiques d'écrantage basse fréquence et bas champ d'écrans supraconducteurs en YBaCuO. Celles-ci se comparent favorablement à celles d'écrans en mumétal. La réalisation pratique d'écrans supraconducteurs est dès lors possible pour l'écrantage de petits volumes. Les géométries de réalisation d'écrans pour les grands volumes sont également discutées.

  20. [A case of cavernous angioma at the convexity in the dura mater: characteristics of images in the literature].

    PubMed

    Yonezawa, Ushio; Ikawa, Fusao; Hamasaki, Osamu; Hidaka, Toshikazu; Kurokawa, Yasuharu; Onuma, Hideyuki

    2014-08-01

    We describe a rare case of cavernous angioma in the dura mater and discuss published MRI findings on similar cases. The patient was a 78-year-old woman who was referred to Shimane Prefectural Central Hospital with complaints of headaches. We were subsequently able to identify a tumor at the convexity in the dura mater. The tumor showed a high intensity on T2-weighted images and was heterogeneously enhanced on contrast-enhanced T1-weighted images. The maximum size of the tumor was 35 mm. Moreover, preoperative angiography showed a slight vascularity in the tumor. We performed surgery with the expectation of finding a meningioma, metastatic brain tumor, or another mesenchymal tumor. The tumor was dark and red, attached to the dura mater, and adhered to the arachnoid. However, we were able to peel the tumor away from the meninges and achieved a total removal of the mass, successfully cutting a fine feeding cortical artery. The patient was discharged without neurological defects 9 days after surgery;the pathological diagnosis was cavernous angioma. In conclusion, it is difficult to discern between meningioma and cavernous angioma in the dura mater. However, the specificity of high intensity on T2-weighted images is relatively high, and preoperative diagnosis can be determined by MRI and angiography findings.

  1. Recovery of ammonia and production of high-grade phosphates from side-stream digester effluents using gas-permeable membranes

    USDA-ARS?s Scientific Manuscript database

    Phosphorus recovery was combined with ammonia recovery using gas-permeable membranes. In a first step, the ammonia and alkalinity were removed from municipal side-stream wastewater using low-rate aeration and a gas-permeable membrane manifold. In a second step, the phosphorus was removed using magne...

  2. Metabolite Concentrations in the Anterior Cingulate Cortex Predict High Neuropathic Pain Impact After Spinal Cord Injury

    DTIC Science & Technology

    2013-02-01

    1Present address: Department of Community Dentistry and Behavioral Science, College of Dentistry , University of Florida, Gainesville, FL, USA. None...energy metabolism in a macaque model of neuro AIDS. Magn Reson Med. 2011; 66:625–34. [PubMed: 21381104] 37. Rosner, B. Fundamentals of biostatistics . 3

  3. A voyage to Mars: space radiation, aging, and nutrition

    USDA-ARS?s Scientific Manuscript database

    On exploratory class missions, such as a voyage to Mars, astronauts will be exposed to doses and types of radiation that are not experienced in low earth orbit where the space shuttle and International Space Station operate. Astronauts who participate in exploratory class missions outside the magne...

  4. Vertical osteoconductivity of sputtered hydroxyapatite-coated mini titanium implants after dura mater elevation: Rabbit calvarial model.

    PubMed

    Wang, Xin; Zakaria, Osama; Madi, Marwa; Kasugai, Shohei

    2015-01-01

    This study evaluated the quantity and quality of newly formed vertical bone induced by sputtered hydroxyapatite-coated titanium implants compared with sandblasted acid-etched implants after dura mater elevation. Hydroxyapatite-coated and non-coated implants (n = 20/group) were used and divided equally into two groups. All implants were randomly placed into rabbit calvarial bone (four implants for each animal) emerging from the inferior cortical layer, displacing the dura mater 3 mm below the original bone. Animals were sacrificed at 4 (n = 5) and 8 (n = 5) weeks post-surgery. Vertical bone height and area were analyzed histologically and radiographically below the original bone. Vertical bone formation was observed in both groups. At 4 and 8 weeks, vertical bone height reached a significantly higher level in the hydroxyapatite compared with the non-coated group (p < 0.05). Vertical bone area was significantly larger in the hydroxyapatite compared with the non-coated group at 4 and 8 weeks (p < 0.05). This study indicates that vertical bone formation can be induced by dura mater elevation and sputtered hydroxyapatite coating can enhance vertical bone formation.

  5. MATER - Pianeta Terra-Mare: an interactive and multidisciplinary approach to Geosphere sciences

    NASA Astrophysics Data System (ADS)

    Piangiamore, Giovanna Lucia; Fanelli, Emanuela; Furia, Stefania; Garau, Daniela; Merlino, Silvia; Musacchio, Gemma; Carla Centineo, Maria

    2016-04-01

    Recent studies demonstrate that Earth and Marine Sciences are not properly treated in scholastic programs and in textbooks are included in a superficial way. These topics are interdisciplinary and experimental (biology, ecology, oceanography and geology) and the recent advance in these fields is strictly linked to technologic improvement. School cannot keep up with the huge advances of knowledge experimented in the last 20 years, also for the lack of didactic laboratories sufficiently updated to support experimental activities. In this context, in 2014-15 three Italian Research Institutes (INGV, ISMAR-CNR and ENEA-CRAM) have decided to support the Unified School District "ISA 10"of Lerici (Liguria, Italy) - comprehensive of kindergartner, primary and middle schools - to develop the project MATER - Pianeta Terra-Mare (Planet Earth and Sea). The acronym MATER (MARe and TERra) has also a gender value, as people involved in the projects were women, mostly researchers and teachers, which have worked side by side with other women belonging to environmental and cultural associations of the territory. This heterogeneous group has a common objective: to promote the diffusion of a scientific culture and to sensitize students from 3 to 14 years towards problems occurring in marine and terrestrial environments, fostering the settlement of a sustainable attitude to the exploitation of natural resources and consciousness to natural hazards, such as earthquakes and floods, quite common in the Ligurian region. MATER has been considered as one of the best projects funded by MIUR (Italian Ministry of Education, University and Research) inside the Dissemination of Scientific and Technological Culture call for the year 2014. Natural hazards (Planet Earth) and the chemical-physical aspects and resources of the marine environment (Planet Sea) were the two modules of the project. Planet Earth developed through Piovono Idee! (Cloudy with a chance of Ideas!), an interactive exhibition on

  6. Transitions de phase dans le oxyde de yttrium vanadium

    NASA Astrophysics Data System (ADS)

    Roberge, Benoit

    Dans le mémoire qui suit, les ordres structural, magnétiques et orbital dans le YVO3 sont étudiés avec l'aide de la diffraction des rayons X,de la spectroscopie Raman et de la technique de la cavité résonnante hyperfréquence. L'objectif premier consiste à observer l'évolution de ces ordres en fonction de la température. Le mémoire met ensuite en évidence le couplage entre les différents ordres cohabitants dans le YVO3 . Les mesures effectuées par la diffraction des rayons X permettent de mesurer le caractère polycrystallin des échantillons du YVO 3. Une comparaison de nos mesures avec des mesures de diffraction des rayons X faites sur la poudre de YVO3 indique la faible présence de maclage. Les mesures effectuées avec la technique de résonnance hyperfréquence permettent de suivre l'évolution de la constante diélectrique en fonction de la température. Les changements impliquant l'ordre orbital se manifestent de manière évidente dans la constante diélectrique à 200 K et à 77 K. La transition diélectrique détectée à 77 K est une transition de premier ordre. Un couplage entre les propriétés diélectriques et magnétiques est observable à la température de Néel à 114 K. L'effet d'un champ magnétique fixe sur la température de transition de l'ordre orbital survenant à 77 K est également remarquable. Cela indique un couplage magnétodiélectrique démontrant ainsi le caractère multiferroïque du YVO 3. Finalement, l'observation d'un mécanisme de relaxation pouvant être modélisé par le modèle d'Havriliak-Negami est observé en dessous de 77 K. En utilisant le modèle d'Arrhénius et le modèle d'Havriliak-Negami, on peut caractériser le mécanisme avec son énergie d'activation et son temps de relaxation. Les mesures effectuées en spectroscopie Raman permettent de suivre l'évolution de la structure du YVO3 en fonction de la température. Les deux changements structuraux survenant à 200 K et 77 K sont observés. Le

  7. The influence of temperature pH and water immersion on the high hydrostatic pressure inactivation of GI.1 and GII.4 human noroviruses

    USDA-ARS?s Scientific Manuscript database

    Detection of human norovirus (HuNoV) usually relies on molecular biology techniques, such as qRT PCR. Since histo-blood group antigens (HBGAs) are the functional receptors for HuNoV, HuNoV can bind to porcine gastric mucin (PGM), which contains HBGA-like antigens. In this study, PGM conjugated magn...

  8. Observation-Based Dissipation and Input Terms for Spectral Wave Models, with End-User Testing

    DTIC Science & Technology

    2013-09-30

    swell dissipation across the ocean. Geophys. Res. Lett., 36, L06607, 4p Ardhuin, F., E. Rogers, A. Babanin, J.-F. Filipot, R. Magne, A. Roland, A. van... definitions , calibration and validations. J. Phys. Oceanogr., 40, 1917-1941 Babanin, A.V., K.N. Tsagareli, I.R Young, and D.J. Walker, 2010: Numerical

  9. Characterization of Nylon 6 by 15N Solid State NMR

    DTIC Science & Technology

    1989-05-31

    M.; Ritchey, W.; de Boer, E. Macromolecules, 1979, 12, 924. 2. Garroway , A. N.; Ritchey, W. M.; Moniz, W. B.; Macromolecules, 1982, It, 1051. 3...E. Macromolecules, 1982, 15, 1406. 23. Veeman, W. S.; Menger, E. M. Bull. Magn. Reson., 1980,2,77. 24. VanderHart, D. L.; Garroway , A. N. J. Chem

  10. Immunohistochemical profile of neurotrophins in human cranial dura mater and meningiomas.

    PubMed

    Artico, Marco; Bronzetti, Elena; Pompili, Elena; Ionta, Brunella; Alicino, Valentina; D'Ambrosio, Anna; Santoro, Antonio; Pastore, Francesco S; Elenkov, Ilia; Fumagalli, Lorenzo

    2009-06-01

    The immunohistochemical profile of neurotrophins and their receptors in the human cranial dura mater was studied by examining certain dural zones in specimens harvested from different regions (frontal, temporal, parietal and occipital). Dural specimens were obtained during neurosurgical operations performed in ten patients for surgical treatment of intracranial lesions (meningiomas, traumas, gliomas, vascular malformations). The dural fragments were taken from the area of the craniotomy at least 8 cm from the lesion as well as from the area in which the meningioma had its dural attachment. Immunohistochemical characterization and distribution of neurotrophins, with their receptors, were analyzed. The concrete role played by these neurotrophic factors in general regulation, vascular permeability, algic responsivity and release of locally active substances in the human dura mater is still controversial. Our study revealed a general structural alteration of dural tissue due to the invasivity of meningiomatous lesions, together with an improved expression of brain derived neurotrophic factor (BDNF) in highly proliferating neoplastic cells and an evident production of nerve growth factor (NGF) in inflammatory cells, suggesting that BDNF has a role in supporting the proliferation rate of neoplastic cells, while NGF is involved in the activation of a chronic inflammatory response in neoplastic areas.

  11. Ultrastructural characteristics of the cranial dura mater-arachnoid interface layer.

    PubMed

    Angelov, D N

    1990-01-01

    The ultrastructural features of the encephalic dura mater-arachnoid borderline (interface) layer (zone) of rats, rabbits, cats and humans were studied. The rat's interface zone included the electron-lucent epithelium-like arranged fibroblasts of the inner dural layer, the rich in filaments cells of the dural neurothelium, a 20 nm wide intercellular cleft filled with electron-dense material and the dark mitochondria-rich cells of the outer arachnoidal layer; in rabbits and cats, this laminar distinction was less prominent, while in man, it was almost absent.

  12. Etude du champ magnetique dans les nuages moleculaires

    NASA Astrophysics Data System (ADS)

    Houde, Martin

    2001-12-01

    Ce travail est une étude du champ magnétique duns l'environnement circumstellaire des étoiles jeunes. Il a pour origine la certitude qu'avait l'auteur qu'il se devait d'être possible de détecter la présence d'un champ magnétique, et de possiblement le caractériser, par le biais d'observations de profils spectraux d'espèces moléculaires ioniques. Il en découle donc qu'un des buts principaux était de prouver que cela est effectivement possible. La thèse comporte alors des éléments théoriques et expérimentaux qui sont à la fois complémentaires et intimement liés. L'aspect théorique est basé sur l'interaction mutuelle que des particules neutres et chargées peuvent avoir l'une sur l'autre daps un plasma faiblement ionisé comme ceux existants daps les nuages moléculaires sites de formation stellaire. Il appert que la présence d'un champ magnétique a un effet direct sur le comportement des ions (via la force de Lorentz) et indirect sur les molécules neutres (via les nombreuses collisions entre les deux types de particules). Une telle interaction est, comme il est maintenant bien connu, présente dans les premières étapes de la formation dune étoile. Il s'agit bien sûr de la diffusion ambipolaire. Nous montrerons qu'il existe cependant un autre type de diffusion, jusqu'ici inconnue, qui se manifeste plus tard au tours de l'évolution des nuages moléculaires. Celle-ci peut avoir un effet dramatique sur l'apparence des profils spectraux (de rotation moléculaire) des espèces ioniques lorsque comparés à ceux qu'exhibent des espèces neutres coexistantes. Mais pour ce faire, il doit y avoir existence de mouvements organisés (des flots ou jets) de matière ou encore la présence de turbulence dans les régions considérées. Une distribution de vélocité du type maxwellienne ne révèlera pas la présence du champ magnétique. Les observations, qui ont pour but de confirmer la théorie, se situent dans le domaine des longueurs d

  13. On ambiente de binárias de pequena massa em formação: o caso do glóbulo cometário CG30 e IRAS08076-3556

    NASA Astrophysics Data System (ADS)

    Hickel, G. R.; Vilas-Boas, J. W. S.

    2003-08-01

    Neste trabalho, combinamos observações de polarização linear no óptico (banda R), dados no infravermelho distante (IRAS) e observações de transições moleculares em radiofreqüências (CO e espécies isotópicas, HCN e HCO+) para analisar o glóbulo cometário (GC) CG30 (na região da IRAS Vela Shell), que apresenta objetos Herbig-Haro e ejeções de matéria, além de uma fonte pontual IRAS em seu interior. Os objetivos deste estudo são: determinar a eficiência de formação estelar nos glóbulos cometários, através da relação entre a massa total do GC e da massa das estrelas em formação; determinar como o campo magnético influencia na formação de estrelas no interior destes objetos; e analisar as modificações que ejeções de matéria de estrelas em formação causam no gás e no campo magnético dos GCs. Combinando nossos dados com trabalhos já publicados, mostramos que CG30 tem uma eficiência de formação estelar em torno de 3%; que o campo magnético é importante na manutenção da estrutura global do GC e demonstra sinais de torção e compressão; e que a ejeção bipolar de matéria das estrelas do par formam uma ejeção quadripolar, a qual influencia na densidade e temperatura do gás e no grau de polarização dos grãos de poeira associados ao gás do GC.

  14. Investigation into the Origin of Magnetic Properties of Amorphous Metallic Alloys.

    DTIC Science & Technology

    1981-10-01

    Luborsky, F.E., J.L. Walter, and D. LeGrand. "Cold Rolling and Annealing of Amor- phous Ribbons," IEEE Trans. Magn. Mag-12, 1976, p. 930. Reprint 8011 ...curve. Iiii) For Fe-B-Al they lie significantly below. The differences between the T, for the three different aluminium containing alloys is not

  15. Theory of Current-Driven Domain Wall Motion

    NASA Astrophysics Data System (ADS)

    Tatara, Gen

    2004-03-01

    . [2] L.Berger, J.Appl.Phys.55,1954(1984); 71,2721(1992);73,6405(1993). [3] J.C.Slonczewski, J.Magn.Magn.Mater. 159,L1(1996); L.Berger, Phys.Rev.B54,9353(1996). [4] S.S.P.Parkin, private communication; T.Ono, private communication.

  16. Walnut Anthracnose

    Treesearch

    Frederick H. Berry

    1981-01-01

    Walnut anthracnose, or leaf blotch as it is sometimes called, is a wide-spread and destructive disease of walnut (Juglans) species, particularly the eastern black walnut (Juglans nigra L.). It is caused by a fungus, Gnomonia leptostyla (Fr.) Ces. and de N., the imperfect stage of which is Marssonia juglandis (Lib.) Magn. The disease may quickly become epidemic during...

  17. Understanding Anion Transport in an Aminated Trimethyl Polyphenylene with High Anionic Conductivity

    DTIC Science & Technology

    2012-01-01

    published online DOI: 10.1002/polb.23164 ABSTRACT: An alkaline exchange membrane (AEM) based on an aminated trimethyl poly(phenylene) is studied in...3874–3882. 23 Cotts, R. M.; Hoch, M. J. R.; Sun, T.; Markert , J. T. J. Magn. Reson. (1969) 1989, 83, 252–266. 24 Tanner, J. E. J. Chem. Phys. 1970

  18. Army Training Study: Battalion Training Survey. Volumes 1 and 2.

    DTIC Science & Technology

    1978-08-08

    mathematical logic in the methodology. II. MAGN ITUJDE-ESTI MAT ION SCALLING A. General Description A unique methodology, Magnitude-Estimation...to 142.) I b " p .’ . -, / 1 ’- " ’. " " . -’ -" ..’- ’ ;’ ’- . "’ .- ’,, • "." -- -. -. -.-. The base conditio (represen.d in T1- sIA , IIA, and IIIA

  19. Solid-State 15N NMR of 15N-Labeled Nylon 6 and Nylon 11

    DTIC Science & Technology

    1990-05-22

    S. Veeman, E. M. Menger, W. Ritchey, and E. de Boer, Macromolecules, 1979, 12, 924. 2. A. N. Garroway , W. M. Ritchey and W. B. Moniz, Macromolecules...S. Veeman and E. M. Menger, Bull. Magn. Reson., 1980, 2, 77. 26. D. L. VanderHart and A. N. Garroway , J. Chem. Phys., 1979, 71, 2773. 27. M. D

  20. Borrelia burgdorferi adhere to blood vessels in the dura mater and are associated with increased meningeal T cells during murine disseminated borreliosis

    PubMed Central

    Divan, Ali; Casselli, Timothy; Narayanan, S. Anand; Mukherjee, Sanjib; Zawieja, David C.; Watt, John A.

    2018-01-01

    Borrelia burgdorferi, the causative agent of Lyme disease, is a vector-borne bacterial infection that is transmitted through the bite of an infected tick. If not treated with antibiotics during the early stages of infection, disseminated infection can spread to the central nervous system (CNS). In non-human primates (NHPs) it has been demonstrated that the leptomeninges are among the tissues colonized by B. burgdorferi spirochetes. Although the NHP model parallels aspects of human borreliosis, a small rodent model would be ideal to study the trafficking of spirochetes and immune cells into the CNS. Here we show that during early and late disseminated infection, B. burgdorferi infects the meninges of intradermally infected mice, and is associated with concurrent increases in meningeal T cells. We found that the dura mater was consistently culture positive for spirochetes in transcardially perfused mice, independent of the strain of B. burgdorferi used. Within the dura mater, spirochetes were preferentially located in vascular regions, but were also present in perivascular, and extravascular regions, as late as 75 days post-infection. At the same end-point, we observed significant increases in the number of CD3+ T cells within the pia and dura mater, as compared to controls. Flow cytometric analysis of leukocytes isolated from the dura mater revealed that CD3+ cell populations were comprised of both CD4 and CD8 T cells. Overall, our data demonstrate that similarly to infection in peripheral tissues, spirochetes adhere to the dura mater during disseminated infection, and are associated with increases in the number of meningeal T cells. Collectively, our results demonstrate that there are aspects of B. burgdorferi meningeal infection that can be modelled in laboratory mice, suggesting that mice may be useful for elucidating mechanisms of meningeal pathogenesis by B. burgdorferi. PMID:29723263

  1. Un test de la variation en dents de scie du champ magnétique terrestre par les anomalies du champ magnétique sur les dorsales

    NASA Astrophysics Data System (ADS)

    Westphal, Michel; Munschy, Marc

    1999-10-01

    In order to test the possible saw-tooth behaviour of the Earth's magnetic field during stable polarity intervals, we selected several magnetic profiles over the East Indian Ridge, the Juan de Fuca Ridge and the East Pacific Rise. We then compared the stacked magnetic anomaly profiles with different models. It appears that neither the uniform pattern nor the saw-tooth pattern fully explain the shape of all anomalies. We propose a new magnetic field model with a gradual transition between Gauss and Matuyama periods and smaller intensities for some short episodes.

  2. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Zhong, X.; Rungger, I.; Zapol, P.

    Understanding electronic properties of substoichiometric phases of titanium oxide such as Magneli phase Ti 4O 7 is crucial in designing and modeling resistive switching devices. Here we present our study on Magneli phase Ti 4O 7 together with rutile TiO 2 and Ti 2O 3 using density functional theory methods with atomic-orbital-based self-interaction correction (ASIC). We predict a new antiferromagnetic (AF) ground state in the low temperature (LT) phase, and we explain energy difference with a competing AF state using a Heisenberg model. The predicted energy ordering of these states in the LT phase is calculated to be robust inmore » a wide range of modeled isotropic strain. We have also investigated the dependence of the electronic structures of the Ti-O phases on stoichiometry. The splitting of titanium t 2g orbitals is enhanced with increasing oxygen deficiency as Ti-O is reduced. Furthermore, the electronic properties of all these phases can be reasonably well described by applying ASIC with a "standard" value for transition metal oxides of the empirical parameter alpha of 0.5 representing the magnitude of the applied self-interaction correction.« less

  3. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Zhong, X.; Rungger, I.; Zapol, P.

    Understanding electronic properties of substoichiometric phases of titanium oxide such as Magneli phase Ti4O7 is crucial in designing and modeling resistive switching devices. Here we present our study on Magneli phase Ti4O7 together with rutile TiO2 and Ti2O3 using density functional theory methods with atomic-orbital-based self-interaction correction (ASIC). We predict a new antiferromagnetic (AF) ground state in the low temperature (LT) phase, and we explain energy difference with a competing AF state using a Heisenberg model. The predicted energy ordering of these states in the LT phase is calculated to be robust in a wide range of modeled isotropic strain.more » We have also investigated the dependence of the electronic structures of the Ti-O phases on stoichiometry. The splitting of titanium t(2g) orbitals is enhanced with increasing oxygen deficiency as Ti-O is reduced. The electronic properties of all these phases can be reasonably well described by applying ASIC with a "standard" value for transition metal oxides of the empirical parameter alpha of 0.5 representing the magnitude of the applied self-interaction correction.« less

  4. Observaciones de la corona solar interior con un coronógrafo de espejo

    NASA Astrophysics Data System (ADS)

    Stenborg, G.; Schwenn, R.; Francile, C.; Rovira, M.

    El plasma de la corona solar es un buen indicador de las líneas de fuerza del campo magnético. Por lo tanto, el análisis de estructuras coronales cuasiestacionarias en la corona da importante información sobre el campo magnético y la actividad asociada. Se trata de poner límites a los modelos teóricos existentes mediante el estudio de distintas estructuras en la corona interior. En agosto de 1997 comenzó a operar el coronógrafo solar (MICA) en El Leoncito como parte del Observatorio Solar Alemán-Argentino. Desde su instalación obtiene imágenes de la corona solar (1.05 a 2.0 radios solares) en 2 líneas espectrales correspondientes a la emisión de Fe XIV y Fe X. El instrumento puede obtener imágenes cada minuto por lo que es ideal para estudiar procesos rápidos. Presentamos observaciones recientes que muestran la capacidad del coronógrafo así como la evolución de algunos eventos dinámicos observados por MICA.

  5. Production of recombinant antigens and antibodies in Nicotiana benthamiana using 'magnifection' technology: GMP-compliant facilities for small- and large-scale manufacturing.

    PubMed

    Klimyuk, Victor; Pogue, Gregory; Herz, Stefan; Butler, John; Haydon, Hugh

    2014-01-01

    This review describes the adaptation of the plant virus-based transient expression system, magnICON(®) for the at-scale manufacturing of pharmaceutical proteins. The system utilizes so-called "deconstructed" viral vectors that rely on Agrobacterium-mediated systemic delivery into the plant cells for recombinant protein production. The system is also suitable for production of hetero-oligomeric proteins like immunoglobulins. By taking advantage of well established R&D tools for optimizing the expression of protein of interest using this system, product concepts can reach the manufacturing stage in highly competitive time periods. At the manufacturing stage, the system offers many remarkable features including rapid production cycles, high product yield, virtually unlimited scale-up potential, and flexibility for different manufacturing schemes. The magnICON system has been successfully adaptated to very different logistical manufacturing formats: (1) speedy production of multiple small batches of individualized pharmaceuticals proteins (e.g. antigens comprising individualized vaccines to treat NonHodgkin's Lymphoma patients) and (2) large-scale production of other pharmaceutical proteins such as therapeutic antibodies. General descriptions of the prototype GMP-compliant manufacturing processes and facilities for the product formats that are in preclinical and clinical testing are provided.

  6. Ultrastructure of the extracellular matrix of bovine dura mater, optic nerve sheath and sclera.

    PubMed

    Raspanti, M; Marchini, M; Della Pasqua, V; Strocchi, R; Ruggeri, A

    1992-10-01

    The sclera, the outermost sheath of the optic nerve and the dura mater have been investigated histologically and ultrastructurally. Although these tissues appear very similar under the light microscope, being dense connective tissues mainly composed of collagen bundles and a limited amount of cells and elastic fibres, they exhibit subtle differences on electron microscopy. In the dura and sclera collagen appears in the form of large, nonuniform fibrils, similar to those commonly found in tendons, while in the optic nerve sheath the fibrils appear smaller and uniform, similar to those commonly observed in reticular tissues, vessel walls and skin. Freeze-fracture also reveals these fibrils to have different subfibrillar architectures, straight or helical, which correspond to 2 distinct forms of collagen fibril previously described (Raspanti et al. 1989). The other extracellular matrix components also vary with the particular collagen fibril structure. Despite their common embryological derivation, the dura mater, optic nerve sheath and sclera exhibit diversification of their extracellular matrix consistent with the mechanical loads to which these tissues are subjected. Our observations indicate that the outermost sheath of the optic nerve resembles the epineurium of peripheral nerves rather than the dura to which it is commonly likened.

  7. Transverse magnetic field effects on the resonant tunneling current

    NASA Astrophysics Data System (ADS)

    Cury, L. A.; Celeste, A.; Goutiers, B.; Portal, J. C.; Sivco, D. L.; Cho, A. Y.

    1991-04-01

    Resonant tunneling process in an (InGa)As-(InAI)As symmetric double-barrier structure subjected to a transverse magnetic field B_{perp} (perpendicular to the current) is investigated. We particularly focus on the experimental behaviour of V_p, the voltage at the current peak position, as a function of the magnetic field B_{perp}. For strong magnetic fields a clear dependence on B_{perp}^2 is observed, as expected. However, an original result is obtained at small magnetic fields where a deviation from the parabolic behaviour is observed. The more complicated dependence on B_{perp} of V_p is obtained from a numerical fit. A qualitative discussion is proposed on the basis of a previous publication (L. A. Cury, A. Celeste, J. C. Portal, Solid-States Electron. 32 (1989) 1689) and the differences with the results of other authors are pointed out. Un système à double barrière à semiconducteurs basé sur les alliages (InGa)As(InAI)As est étudié sous un fort champ magnétique transverse B_{perp} (perpendiculaire au courant). On étudie plus particulièrement la variation expérimentale de la tension V_p associée au courant pic en fonction du champ magnétique B_{perp}. A très fort champ, le comportement attendu de V_p en B_{perp}^2 est observé. Dans le domaine des bas champs magnétiques une déviation du comportement quadratique est mise en évidence. Le comportement plus compliqué de V_p en fonction de B_{perp} est obtenu au travers d'un lissage numérique. Nous proposons une discussion qualitative, de ces résultats, fondée sur notre travail antérieur (L. A. Cury, A. Celeste, J. C. Portal, Solid-States Electron. 32 (1989) 1689) ainsi qu'une comparaison avec les résultats d'autres auteurs.

  8. Biological Effects of Clinically Relevant CoCr Nanoparticles in the Dura Mater: An Organ Culture Study

    PubMed Central

    Papageorgiou, Iraklis; Abberton, Thomas; Fuller, Martin; Tipper, Joanne L.; Fisher, John; Ingham, Eileen

    2014-01-01

    Medical interventions for the treatment of spinal disc degeneration include total disc replacement and fusion devices. There are, however, concerns regarding the generation of wear particles by these devices, the majority of which are in the nanometre sized range with the potential to cause adverse biological effects in the surrounding tissues. The aims of this study were to develop an organ culture model of the porcine dura mater and to investigate the biological effects of CoCr nanoparticles in this model. A range of histological techniques were used to analyse the structure of the tissue in the organ culture. The biological effects of the CoCr wear particles and the subsequent structural changes were assessed using tissue viability assays, cytokine assays, histology, immunohistochemistry, and TEM imaging. The physiological structure of the dura mater remained unchanged during the seven days of in vitro culture. There was no significant loss of cell viability. After exposure of the organ culture to CoCr nanoparticles, there was significant loosening of the epithelial layer, as well as the underlying collagen matrix. TEM imaging confirmed these structural alterations. These structural alterations were attributed to the production of MMP-1, -3, -9, -13, and TIMP-1. ELISA analysis revealed that there was significant release of cytokines including IL-8, IL-6, TNF-α, ECP and also the matrix protein, tenascin-C. This study suggested that CoCr nanoparticles did not cause cytotoxicity in the dura mater but they caused significant alterations to its structural integrity that could lead to significant secondary effects due to nanoparticle penetration, such as inflammation to the local neural tissue. PMID:28344233

  9. Increasing the oscillation frequency of strong magnetic fields above 101 kHz significantly raises peripheral nerve excitation thresholds

    PubMed Central

    Weinberg, Irving N.; Stepanov, Pavel Y.; Fricke, Stanley T.; Probst, Roland; Urdaneta, Mario; Warnow, Daniel; Sanders, Howard; Glidden, Steven C.; McMillan, Alan; Starewicz, Piotr M.; Reilly, J. Patrick

    2012-01-01

    Purpose: A time-varying magnetic field can cause unpleasant peripheral nerve stimulation (PNS) when the maximum excursion of the magnetic field (ΔB) is above a frequency-dependent threshold level [P. Mansfield and P. R. Harvey, Magn. Reson. Med. 29, 746–758 (1993)]. Clinical and research magnetic resonance imaging (MRI) gradient systems have been designed to avoid such bioeffects by adhering to regulations and guidelines established on the basis of clinical trials. Those trials, generally employing sinusoidal waveforms, tested human responses to magnetic fields at frequencies between 0.5 and 10 kHz [W. Irnich and F. Schmitt, Magn. Reson. Med. 33, 619–623 (1995), T. F. Budinger et al., J. Comput. Assist. Tomogr. 15, 909–914 (1991), and D. J. Schaefer et al., J. Magn. Reson. Imaging 12, 20–29 (2000)]. PNS thresholds for frequencies higher than 10 kHz had been extrapolated, using physiological models [J. P. Reilly et al., IEEE Trans. Biomed. Eng. BME-32(12), 1001–1011 (1985)]. The present study provides experimental data on human PNS thresholds to oscillating magnetic field stimulation from 2 to 183 kHz. Sinusoidal waveforms were employed for several reasons: (1) to facilitate comparison with earlier reports that used sine waves, (2) because prior designers of fast gradient hardware for generalized waveforms (e.g., including trapezoidal pulses) have employed quarter-sine-wave resonant circuits to reduce the rise- and fall-times of pulse waveforms, and (3) because sinusoids are often used in fast pulse sequences (e.g., spiral scans) [S. Nowak, U.S. patent 5,245,287 (14 September 1993) and K. F. King and D. J. Schaefer, J. Magn. Reson. Imaging 12, 164–170 (2000)]. Methods: An IRB-approved prospective clinical trial was performed, involving 26 adults, in which one wrist was exposed to decaying sinusoidal magnetic field pulses at frequencies from 2 to 183 kHz and amplitudes up to 0.4 T. Sham exposures (i.e., with no magnetic fields) were applied to all

  10. Laser bonding with ICG-infused chitosan patches: preliminary experiences in suine dura mater and vocal folds

    NASA Astrophysics Data System (ADS)

    Rossi, Francesca; Matteini, Paolo; Ratto, Fulvio; Pini, Roberto; Iacoangeli, Maurizio; Giannoni, Luca; Fortuna, Damiano; Di Cicco, Emiliano; Corbara, Sylwia; Dallari, Stefano

    2014-05-01

    Laser bonding is a promising minimally invasive approach, emerging as a valid alternative to conventional suturing techniques. It shows widely demonstrated advantages in wound treatment: immediate closuring effect, minimal inflammatory response and scar formation, reduced healing time. This laser based technique can overcome the difficulties in working through narrow surgical corridors (e.g. the modern "key-hole" surgery as well as the endoscopy setting) or in thin tissues that are impossible to treat with staples and/or stitches. We recently proposed the use of chitosan matrices, stained with conventional chromophores, to be used in laser bonding of vascular tissue. In this work we propose the same procedure to perform laser bonding of vocal folds and dura mater repair. Laser bonding of vocal folds is proposed to avoid the development of adhesions (synechiae), after conventional or CO2 laser surgery. Laser bonding application in neurosurgery is proposed for the treatment of dural defects being the Cerebro Spinal Fluid leaks still a major issue. Vocal folds and dura mater were harvested from 9-months old porks and used in the experimental sessions within 4 hours after sacrifice. In vocal folds treatment, an IdocyanineGreen-infused chitosan patch was applied onto the anterior commissure, while the dura mater was previously incised and then bonded. A diode laser emitting at 810 nm, equipped with a 600 μm diameter optical fiber was used to weld the patch onto the tissue, by delivering single laser spots to induce local patch/tissue adhesion. The result is an immediate adhesion of the patch to the tissue. Standard histology was performed, in order to study the induced photothermal effect at the bonding sites. This preliminary experimental activity shows the advantages of the proposed technique in respect to standard surgery: simplification of the procedure; decreased foreign-body reaction; reduced inflammatory response; reduced operating times and better handling in

  11. Wireless, Acoustically Linked, Undersea, Magnetometer Sensor Network

    DTIC Science & Technology

    2010-06-01

    Hull Street, San Diego, CA 92152 mihajlo.tomic@navy.mil, sullivap@spawar.navy.mil, keyko.mcdonald.navy.mil Abstract—This paper presents a magnetometer...sensor node design that consists of a He3 nuclear precession total-field magne- tometer, data acquisition and recording electronics, and acoustic modem...detection range, thereby minimizing the overall number of required nodes to cover a given area. Given the aversion to continuously streaming data via the

  12. Distributed Systems Technology Survey.

    DTIC Science & Technology

    1987-03-01

    and prolocols. 2. Hardware Technology Ecnomic factor we a majo reonm for the prolierat of dlstbted systoe. Processors, memory, an magne tc ndoptical...destined messages and pertorn the a pro te forwarding. There gImsno agreement that a ightweight process mechanism is essential to support com- monly used...Xerox PARC environment [311. Shared file servers, discussed below, are essential to the success of such a scheme. 11. ecurlity A distributed

  13. Dura mater graft-associated Creutzfeldt-Jakob disease with 30-year incubation period.

    PubMed

    Shijo, Masahiro; Honda, Hiroyuki; Koyama, Sachiko; Ishitsuka, Koji; Maeda, Koichiro; Kuroda, Junya; Tanii, Mitsugu; Kitazono, Takanari; Iwaki, Toru

    2017-06-01

    Over 60% of all patients with dura mater graft-associated Creutzfeldt-Jakob disease (dCJD) have been diagnosed in Japan. The incubation period has ranged from 1 to 30 years and the age at onset from 15 to 80 years. Here, we report a 77-year-old male Japanese autopsied dCJD case with the longest incubation period so far in Japan. He received a cadaveric dural graft at the right cranial convexity following a craniotomy for meningioma at the age of 46. At 30 years post-dural graft placement, disorientation was observed as an initial symptom of dCJD. He rapidly began to present with inconsistent speech, cognitive impairment and tremor of the left upper extremity. Occasional myoclonic jerks were predominantly observed on the left side. Brain MRI presented hyperintense signals on diffusion-weighted and T2-weighted images, at the right cerebral cortex. The most hyperintense lesion was located at the right parietal lobe, where the dura mater graft had been transplanted. Single-photon emission CT scan showed markedly decreased cerebral blood flow at the right parietal lobe. EEG revealed diffuse and slow activities with periodic sharp-wave complex discharges seen in the right parietal, temporal and occipital lobes. He died of pneumonia 9 months after onset. Brain pathology revealed non-plaque-type dCJD. Laterality of neuropathological changes, including spongiform change, neuronal loss, gliosis or PrP deposits, was not evident. Western blot analysis showed type 1 PrP CJD . Alzheimer-type pathology and PSP-like pathology were also observed. © 2016 Japanese Society of Neuropathology.

  14. Experimental determination of the magnetic dipole moment of candidate magnetoreceptor cells in trout

    NASA Astrophysics Data System (ADS)

    Winklhofer, M.; Eder, S.; Cadioiu, H.; McNaughton, P. A.; Kirschvink, J. L.

    2011-12-01

    magnetic types of magnetotactic bacteria (Hanzlik et al. 2002). Our results demonstrate that the magnetically identified cells clearly meet the physical requirements for a magnetoreceptor capable of rapidly detecting small changes in the external magnetic field. Diebel, C.E., Proksch, R., Green, C.R., Neilson, P. & Walker, M.M. (2000) Magnetite defines a vertebrate magnetoreceptor. Nature 406, 299-302. Hanzlik, M., Winklhofer, M., Petersen, N. (2002) Pulsed-field-remanence measurements on individual magnetotactic bacteria, J. Magn. Magn. Mater., 248(2), 258-267. Walker, M.M., Diebel, C.E., Haugh, C.V., Pankhurst, P.M., Montgomery, J.C. & Green, C.R. (1997) Structure and function of the vertebrate magnetic sense. Nature 390, 371-376.

  15. Impact of holmium fibre laser radiation (λ = 2.1 μm) on the spinal cord dura mater and adipose tissue

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Filatova, S A; Kamynin, V A; Ryabova, A V

    The impact of holmium fibre laser radiation on the samples of biologic tissues (dura mater of spinal cord and adipose tissue with interlayers of muscle) is studied. The experimental results are evaluated by the size of carbonisation and coagulation necrosis zones. The experiment shows that in the case of irradiation of the spinal cord dura mater samples the size of carbonisation and coagulation necrosis zones is insignificant. In the adipose tissue the carbonisation zone is also insignificant, but the region of cellular structure disturbance is large. In the muscle tissue the situation is opposite. The cw laser operation provides clinicallymore » acceptable degree of destruction in tissue samples with a minimal carbonisation zone. (laser applications in medicine)« less

  16. Ultrastructure of the extracellular matrix of bovine dura mater, optic nerve sheath and sclera.

    PubMed Central

    Raspanti, M; Marchini, M; Della Pasqua, V; Strocchi, R; Ruggeri, A

    1992-01-01

    The sclera, the outermost sheath of the optic nerve and the dura mater have been investigated histologically and ultrastructurally. Although these tissues appear very similar under the light microscope, being dense connective tissues mainly composed of collagen bundles and a limited amount of cells and elastic fibres, they exhibit subtle differences on electron microscopy. In the dura and sclera collagen appears in the form of large, nonuniform fibrils, similar to those commonly found in tendons, while in the optic nerve sheath the fibrils appear smaller and uniform, similar to those commonly observed in reticular tissues, vessel walls and skin. Freeze-fracture also reveals these fibrils to have different subfibrillar architectures, straight or helical, which correspond to 2 distinct forms of collagen fibril previously described (Raspanti et al. 1989). The other extracellular matrix components also vary with the particular collagen fibril structure. Despite their common embryological derivation, the dura mater, optic nerve sheath and sclera exhibit diversification of their extracellular matrix consistent with the mechanical loads to which these tissues are subjected. Our observations indicate that the outermost sheath of the optic nerve resembles the epineurium of peripheral nerves rather than the dura to which it is commonly likened. Images Fig. 1 Fig. 2 Fig. 3 Fig. 4 Fig. 5 Fig. 6 Fig. 7 Fig. 8 Fig. 9 PMID:1295858

  17. Magnetic Resonance Characterization of Axonal Response to Spinal Cord Injury

    DTIC Science & Technology

    2014-12-01

    73(2):614-22. doi: 10.1002/ mrm .25174. Epub 2014 Mar 6) and in generating spinal cord myelin maps (Magnetization transfer from inhomogeneously...Rangwala N, Alsop DC, Duhamel G. Magn Reson Med. 2016 Mar 9. doi: 10.1002/ mrm .26134. [Epub ahead of print]) The third aim, to extend quantitative...resolution and gradient stability that off the shelf alternatives. However, the incompatibility of the coil and software with the new instrument introduced

  18. Synthesis and Mass Spectra of Butenyltin Compounds

    DTIC Science & Technology

    1989-03-01

    activities or operations. One instance of this concern has focused on the Navy’s use of tributyltin compounds as antifoulants on ships’ hulls. Such...butene, and 1-chloro- 2-butene were obtained from Pfaltz & Bauer (Waterbury, CT). Resublimed magne- sium chips, tetrabutyltin and tributyltin bromide...preferential elimination of R minus R to form RSn ’from R3Sn + The fragmentation patterns of tributyltin bromide and tributenyltin bromides are dominated

  19. Evidence for novel age-dependent network structures as a putative primo vascular network in the dura mater of the rat brain

    PubMed Central

    Lee, Ho-Sung; Kang, Dai-In; Yoon, Seung Zhoo; Ryu, Yeon Hee; Lee, Inhyung; Kim, Hoon-Gi; Lee, Byung-Cheon; Lee, Ki Bog

    2015-01-01

    With chromium-hematoxylin staining, we found evidence for the existence of novel age-dependent network structures in the dura mater of rat brains. Under stereomicroscopy, we noticed that chromium-hematoxylin-stained threadlike structures, which were barely observable in 1-week-old rats, were networked in specific areas of the brain, for example, the lateral lobes and the cerebella, in 4-week-old rats. In 7-week-old rats, those structures were found to have become larger and better networked. With phase contrast microscopy, we found that in 1-week-old rats, chromium-hematoxylin-stained granules were scattered in the same areas of the brain in which the network structures would later be observed in the 4- and 7-week-old rats. Such age-dependent network structures were examined by using optical and transmission electron microscopy, and the following results were obtained. The scattered granules fused into networks with increasing age. Cross-sections of the age-dependent network structures demonstrated heavily-stained basophilic substructures. Transmission electron microscopy revealed the basophilic substructures to be clusters with high electron densities consisting of nanosized particles. We report these data as evidence for the existence of age-dependent network structures in the dura mater, we discuss their putative functions of age-dependent network structures beyond the general concept of the dura mater as a supporting matrix. PMID:26330833

  20. Impuretés et systèmes corrélés. Des chaînes aux cuprates supraconducteurs

    NASA Astrophysics Data System (ADS)

    Bobroff, J.

    2005-01-01

    Impurities and correlated systems Discovery of high TC superconductors has opened the new field of strongly correlated fermions physics. In these compounds, mostly transition metal oxides, strong correlations between electrons affect sharply their electronic properties. In order to determine accurately these correlations and their possible link with superconductivity, we study the effect of local defects such as non magnetic impurities. In fact, in the more simple case of insulating spin chains and ladders, these impurities induce a staggered magnetism in their neighborhood which reveals the underlying electronic correlations. Similar effects are observed in high TC superconductors, using local probes such as nuclear magnetic resonance. These observations allow to get a better understanding of both normal and superconducting state of these oxides, both full of surprises. La découverte des supraconducteurs à haute température critique a ouvert la voie à une nouvelle physique, celle des fermions fortement corrélés. Dans ces systèmes, le plus souvent des oxydes de métaux de transition, les fortes corrélations entre électrons affectent profondément leurs propriétés électroniques et induisent de nouveaux états originaux : liquides de spins, supraconductivité, etc. Pour mesurer ces corrélations et ainsi déterminer leur lien éventuel avec la supraconductivité, nous proposons d'étudier l'effet de défauts ponctuels tels que des impuretés non magnétiques. En effet, dans le cas plus simple de chaînes ou d'échelles de spin isolantes, ces impuretés induisent dans leur voisinage immédiat un magnétisme alterné révélateur des corrélations électroniques. Des effets semblables sont observés dans les supraconducteurs à haute température critique, grâce à des sondes locales comme la résonance magnétique nucléaire. Ces observations permettent de mieux comprendre à la fois l'état normal et supraconducteur de ces oxydes, tous deux riches en

  1. Transrectal Near-Infrared Optical Tomography for Prostate Imaging

    DTIC Science & Technology

    2009-03-01

    using a directional transurethral ultrasound applicator,” J Magn Reson Imaging., 15(4), 409-17. Iftimia N , and Jiang H (2000), “Quantitative... N , Carroll PR, Flax J, Blumenfeld W, and Folkman J (1993), "Tumor angiogenesis correlates with metastasis in invasive prostate carcinoma," Am J...34 JAMA. 281, 1591-1597 (1999). 6. A. C. Loch, A. Bannowsky, L. Baeurle, B. Grabski, B. König, G. Flier, O. Schmitz-Krause, U. Paul , and T. Loch

  2. [Electrophysiological correlates of efficacy of nootropic drugs in the treatment of consequences of traumatic brain injury in adolescents].

    PubMed

    Iznak, E V; Iznak, A F; Pankratova, E A; Zavadenko, N N; Guzilova, L S; Guzilova, Iu I

    2010-01-01

    To assess objectively a dynamics of brain functional state, EEG spectral power and peak latency of the P300 component of cognitive auditory evoked potentials have been analyzed in adolescents during the course of nootropic therapy of residual asthenic consequences of traumatic brain injury (ICD-10 F07.2). The study included 76 adolescents, aged 12-18 years, who have undergone severe closed head trauma with brain commotion 1/2--5 years ago. Patients have been divided into 3 groups treated during one month with cerebrolysin, piracetam or magne-B6, respectively. After the end of the nootropic therapy, 77% of patients treated with cerebrolysin as well as 50% of patients treated with piracetam and magne-B6 have demonstrated the positive dynamics of their brain functional state that manifested itself in the appearance of occipital EEG alpha rhythm or in the increase of its spectral power; in the normalization of alpha rhythm frequency; in the decrease in the spectral power of slow wave (theta and delta) EEG activity, in the amount (up to the disappearance) of paroxysmal EEG activity, in the EEG response to hyperventilation and in the shortening of the P300 peak latency. Such positive changes of neurophysiological parameters have been associated with the improvement of clinical conditions of patients and correlated significantly with the dynamics of psychometric scores of attention and memory.

  3. Intracellular Osmolyte Distributions Assessed by ^1H and ^23Na Magnetic Resonance Microscopy

    NASA Astrophysics Data System (ADS)

    Grant, Samuel

    2007-03-01

    Recently, Magnetic Resonance Microscopy (MRM) has been applied to the high resolution imaging and localized spectroscopy of isolated cells^1,2. With resolutions <40 μm, these efforts have demonstrated the diverse intracellular environments that can be probed by proton MRM to provide insight into the compartmental diffusion and relaxation of intracellular water and metabolites. In this study, the intracellular distribution of the inorganic osmolyte sodium in isolated single neurons is assessed by MRM through the acquisition of three-dimensional (3D) microimages by direct observation of ^23Na. These efforts are made possible through (a) the use of a specially constructed, double-tuned Radio Frequency (RF) microcoil and (b) the application of a unique, ultra-widebore 21.1-T magnet. Results show an increased sodium signal in the nucleus of the L7 neuron of aplysia Californica. These ^23Na findings are compared with MR data that display a heterogeneous distribution of the organic osmolyte betaine, which appears to be localized at high concentrations to the cytoplasm. The link between the intracellular distributions of sodium and other osmolytes in this single neuron model may shed light on intracellular osmoregulatory processes, particularly in response to toxic or pathological perturbations. ^1S.C.Grant, et al., Magn. Reson. Med. 2000. ^2S.C.Grant, et al., Magn. Reson. Med. 2001.

  4. Influence de l'effet de peau sur la rotation d'un rotor fluide

    NASA Astrophysics Data System (ADS)

    Witkowski, L. Martin; Marty, Ph.

    1998-01-01

    A rotating magnetic field creates forces in a liquid metal column which therefore rotates. In the case of an infinitely long column, we solve the induction and Navier-Stokes equations. The results are described for the fully coupled case which arises when the Hartmann number Ha and the shield parameter R_{ω} are larger than unity. In this case, we distinguish between two velocity regimes upon the value of R_{ω} with respect to frac{Ha}{sqrt{2}}. Un champ magnétique tournant autour d'une colonne de métal liquide crée des forces qui la mettent en rotation. Dans le cas d'une colonne de hauteur infinie, il est proposé une méthode de résolution des équations couplées régissant la distribution du champ magnétique et du champ de vitesse. Les résultats sont détaillés quand le couplage est fort ce qui correspond à un nombre de Hartmann Ha et un paramètre d'écran R_{ω} grands devant l'unité. Dans ce cas, pour Ha donné, deux régimes apparaissent pour le champ de vitesse suivant que R_{ω} est supérieur ou inférieur à frac{Ha}{sqrt{2}}.

  5. Lasers à électrons libres de courtes longueurs d'onde: état de l'art et perspectives

    NASA Astrophysics Data System (ADS)

    Couprie, M. E.

    2003-06-01

    Les Lasers à Électrons Libres (LEL) sont des sources de rayonnement cohérent et accordable, basées sur l'interaction d'un faisceau d'électrons relativistes circulant dans le champ magnétique magnétique périodique et permanent créé par un “onduleur”. et d'une onde optique. L'onde lumineuse peut être issue de l'émission de rayonnement synchroton émise par le paquet d'électrons a chaque passage pour un système super-radiant en mode SASE (Self Amplified Spontaneous Emission- Emission Spontanée Auto-Amplifiée) ou issue du rayonnement synchrotron stocké dans une cavité optique, en mode oscillateur, ou d'une onde laser externe, en mode génération d'harmonique. Sous certaines conditions, l'onde lumineuse est amplifiée, au détriment de l'énergie cinétique des électrons, ce qui conduit à l'effet laser. L'état de l'art des sources Laser à Electrons Libres dans l'UV et le VUV est présenté, en indiquant les complémentarités résultant des différentes configurations tant du point de vue des sources que de leurs utilisations. Les projets de sources de courte longueur d'onde proposés sont ensuite discutés.

  6. Clinical experience with a novel bovine collagen dura mater substitute

    PubMed Central

    Costa, Bruno Silva; Cavalcanti-Mendes, George de Albuquerque; de Abreu, Marcelo Sartori; de Sousa, Atos Alves

    2010-01-01

    Background: Dural substitutes are used to achieve a watertight closure in situations where adequate closure is not possible .This study was conducted to evaluate the efficacy and safety of use a new collagen matrix dural substitute ( Duradry, Tecnodry, Belo Horizonte MG) in repair or expansion of cranial and spinal dura-mater. Methods: 30 patients operated on between March and September 2008, were studied. Surgical logs were reviewed for sex, age, diagnosis, location of the graft, technique and presence of fistula or infection. The patients were followed-up for at least 3 months, and the presence of complications as cerebrospinal leakage, infection, aseptic meningitis, hydrocephalus, pseudomeningocele were analysed. Results: Only one patient presented with CSF fistula. No patients presented with wound infections, hydrocephalus, pseudomeningocele, meningitis, brain abscesses or signs of toxicity related to the material. Conclusions: The new dural substitute used in this study is effective and safe, and the initial results are similar to those of other dural substitutes reported in the literature. PMID:22028756

  7. Mechanical suitability of glycerol-preserved human dura mater for construction of prosthetic cardiac valves.

    PubMed

    McGarvey, K A; Lee, J M; Boughner, D R

    1984-03-01

    We have examined the tensile viscoelastic properties of fresh and glycerol-preserved human dura mater, and correlated the results with structural information from the scanning electron microscope. The interwoven laminar structure of dura produces rather high flexural stiffness, while the crossed-fibrillar laminae produce planar mechanical isotropy. Glycerol storage shifts the stress-strain curve to lower strain, reduces stress relaxation and creep, and lowers the ultimate tensile strength and strain at fracture. These changes may be due to glyceraldehyde crosslinking, or to increased interfibrillar friction. The latter hypothesis suggests that glycerol storage may reduce the fatigue lifetime of the tissue.

  8. Finite Elements, Design Optimization, and Nondestructive Evaluation: A Review in Magnetics, and Future Directions in GPU-based, Element-by-Element Coupled Optimization and NDE

    DTIC Science & Technology

    2013-07-18

    Nationale Supérieure d’Ingénieurs Electriciens de Grenoble (ENSIEG) group led by J.C. Sabonnadiere, J.L. Coulomb and G. Meunier would bring mathematical...1985. [11] J.L. Coulomb , “Analyse tridimensionnelle des champs électriques et magnétiques par la méthode des éléments finis,” These de Doctorat...computations by the virtual work principle [10]. However Coulomb [11-13] of the ENSIEG group identified a one-step solution for the computation of

  9. Corrosion Control through a Better Understanding of the Metallic Substrate/Organic Coating/Interface

    DTIC Science & Technology

    1989-02-06

    Mdssbauer Spectroscopy to Studies of Electrodeposits and the Chemistry of Metal Surfaces," Henry Leidheiser, Jr., J. Electrochem. Soc. 135(2), 5C-11C (1988...VanderHart, D. L. J.agn. Res, 1982, 48, 35. -21- (22) Venkatachalam, C. M.; Urry, D. W. J. Magn. Res, 1980, 41, 313. (23) Deck, P. PhD Thesis , Lehigh...that can serve as nucleation sites for the formation of an aqueous phase. Reduction in the probability that nucleation sites exist at the interface

  10. Repair, Evaluation, Maintenance, and Rehabilitation Research Program: Evaluation of Civil Works Metal Structures

    DTIC Science & Technology

    1991-01-01

    can be per- formed at any time, as a spot check, or periodically. Liauid Penetrant Inspection (PT) 19. Aplication . Liquid penetrant testing (PT) is a...increases the inspection \\MAGNE TIC PARTICLESiA - CRACK- Figure 6. Crack in bar magnet attracting magnetic particles 14 particle mobility and enables the...923-9800 or (312) 474-5860 Service: IA, IL, IN, MI, WI LOUISIANA O.S.I. Mobile Lab, Inc. X-Ray Inspection, Inc. P. 0. Box 395 P. 0. Box 51651 Harvey

  11. Estudo em microondas do aprisionamento e precipitação de elétrons em explosões solares

    NASA Astrophysics Data System (ADS)

    Rosal, A. C.; Costa, J. E. R.

    2003-08-01

    Uma explosão solar é uma variação rápida e intensa do brilho que ocorre nas chamadas regiões ativas da atmosfera, constituídas por um plasma magnetizado com intensa indução magnética. Os modelos de explosões solares atuais, discutidos na literatura, apresentam características de aprisionamento e precipitação de elétrons em ambientes magnéticos simplificados. Neste trabalho, nos propusemos a separar a emissão dos elétrons aprisionados da emissão dos elétrons em precipitação apenas a partir da emissão em microondas, melhorando portanto o controle sobre o conjunto de parâmetros inferidos. A emissão em microondas da população em precipitação é bastante fraca e portanto da nossa base de dados de 130 explosões observadas pelo Rádio Polarímetro de Nobeyama, em sete freqüências, apenas para 32 foi possível separar as duas componentes de emissão com uma boa razão sinal/ruído. A partir de estudos das escalas de tempo das emissões devidas à variação gradual da emissão no aprisionamento e da variação rápida da emissão dos elétrons em precipitação foi possível obter a separação utilizando um filtro temporal nas emissões resultantes. Em nossa análise destas explosões estudamos os espectros girossincrotrônicos da emissão gradual, a qual associamos provir do topo dos arcos magnéticos e da emissão de variação rápida associada aos elétrons em precipitação. Estes espectros foram calculados e dos quais inferimos que a indução magnética efetiva do topo e dos pés foi em média, Btopo = 236 G e Bpés = 577 G, inferidas das freqüências de pico dos espectros em ntopo = 11,8 GHz e npés = 14,6 GHz com leve anisotropia (pequeno alargamento espectral). O índice espectral da distribuição não-térmica de elétrons d, inferido do índice espectral de fótons da emissão em regime opticamente fino, foi de dtopo = 3,3 e dpés = 3,9. Estes parâmetros são típicos da maioria das análises realizadas em ambiente único de

  12. Contrast Enhancement for Thermal Acoustic Breast Cancer Imaging via Resonant Stimulation

    DTIC Science & Technology

    2009-03-01

    structures,” Appl . Opt., vol. 39, no. 31, pp. 5872–5883, 2000. [12] D. Feng, Y. Xu, G. Ku, and L. V. Wang, “Microwave-induced thermoa- coustic tomography...image recon- struction,” Appl . Opt., vol. 39, no. 32, pp. 5971–5977, 2000. [14] G. Kossoff, E. K. Fry, and J. Jellins, “Average velocity of ultrasound...P. Stoica, and R. Wu, “Microwave imaging via adaptive beamforming methods for breast cancer detection,” J. Electro- magn. Waves Appl ., vol. 20, no. 1

  13. Compression médullaire d'origine métastatique

    PubMed Central

    Bouhafa, Touria; Elmazghi, Abderrahman; Masbah, Ouafae; Hassouni, Khalid

    2014-01-01

    La compression médullaire d'origine métastatique est une complication neurologique fréquente du cancer. C'est une urgence diagnostique et thérapeutique qui nécessite une prise en charge rapide et efficace. L'imagerie par résonnance magnétique (IRM) constitue l'examen de choix pour l'exploration de l'ensemble de la moelle. La prise en charge thérapeutique doit être multidisciplinaire incluant la corticothérapie, la radiothérapie et la chirurgie. PMID:25829974

  14. Application of the Angular Overlap Model to Lanthanide Phthalocyanines (Aplicacion Del Modelo de Traslape Angular a Ftalocinaninas de Lantanidos)

    DTIC Science & Technology

    1989-07-15

    metilicos. Esto trae a la teoria del campo ligante el concepto de grupos funcionales. En este trabajo se us6 el enfoque del MTA desarrollado por...susceptibilidades magne’ticas se hizo de acuerdo a la teoria de perturbaciones usando la ecuacio’n de Van Vleckc. Es importante recordar que a pesar de...en el anillo pirrolico la deslocalizacio’n en el grupo imina es peque? a, y el sistema no se altera mucho debido a la donaci6n W. A partir de lus

  15. Follicular progesterone concentrations and messenger RNA expression of MATER and OCT-4 in immature bovine oocytes as predictors of developmental competence.

    PubMed

    Urrego, R; Herrera-Puerta, E; Chavarria, N A; Camargo, O; Wrenzycki, C; Rodriguez-Osorio, N

    2015-04-15

    The ability of bovine embryos to develop to the blastocyst stage and to implant and generate healthy offspring depends greatly on the competence of the oocyte. Oocyte competence is attributed to its close communication with the follicular environment and to its capacity to synthesize and store substantial amounts of messenger RNA. Higher developmental competence of bovine oocytes has been associated with both the expression of a cohort of developmental genes and the concentration of sex steroids in the follicular fluid. The aim of this study was to identify differences in the expression of FST in cumulus cells and OCT-4 and MATER in oocytes and the influence of the follicular progesterone and follicular estrogen concentration on the competence of bovine oocytes retrieved 30 minutes or 4 hours after slaughter. Cumulus-oocyte complexes (COCs) were left in postmortem ovaries for 30 minutes (group I) or 4 hours (group II) at 30 °C. Aspirated oocytes were then subjected to IVM, IVF, and IVC or were evaluated for MATER and OCT-4 messenger RNA abundance by quantitative real-time polymerase chain reaction. Total RNA was isolated from pools of 100 oocytes for each experimental replicate. Progesterone and estradiol concentration in follicular fluid was evaluated by immunoassay using an IMMULITE 2000 analyzer. Three repeats of in vitro embryo production were performed with a total of 455 (group I) and 470 (group II) COCs. There were no significant differences between the cleavage rates (72 hours postinsemination [hpi]) between both groups (63.5% vs. 69.1%). However, blastocyst (168 hpi) and hatching (216 hpi) rates were higher (P < 0.05) in group II compared with those of group I (21.3% vs. 30.7% and 27.6% vs. 51.5%, respectively). Group II oocytes exhibited the highest MATER and OCT-4 abundance (P < 0.05). Follicular estradiol concentration was not different between both the groups, whereas the progesterone concentration was lower (P ≤ 0.05) in group II follicles. These

  16. Quantum Monte Carlo simulations of Ti4 O7 Magnéli phase

    NASA Astrophysics Data System (ADS)

    Benali, Anouar; Shulenburger, Luke; Krogel, Jaron; Zhong, Xiaoliang; Kent, Paul; Heinonen, Olle

    2015-03-01

    Ti4O7 is ubiquitous in Ti-oxides. It has been extensively studied, both experimentally and theoretically in the past decades using multiple levels of theories, resulting in multiple diverse results. The latest DFT +SIC methods and state of the art HSE06 hybrid functionals even propose a new anti-ferromagnetic state at low temperature. Using Quantum Monte Carlo (QMC), as implemented in the QMCPACK simulation package, we investigated the electronic and magnetic properties of Ti4O7 at low (120K) and high (298K) temperatures and at different magnetic states. This research used resources of the Argonne Leadership Computing Facility at Argonne National Laboratory, which is supported by the Office of Science of the U.S. Department of Energy under contract DE-AC02-06CH11357. L.S, J.K and P.K were supported through Predictive Theory and Modeling for Materials and Chemical Science program by the Office of Basic Energy Sciences (BES), Department of Energy (DOE) Sandia National Laboratories is a multiprogram laboratory managed and operated by Sandia Corporation, a wholly owned subsidiary of Lockheed Martin Corporation, for the U.S. Department of Energy's National Nuclear Security Administration under Contract No. DE-AC04-94AL85000.

  17. Proliferative capacity and osteogenic potential of novel dura mater stem cells on poly-lactic-co-glycolic acid.

    PubMed

    Petrie, Caren; Tholpady, Sunil; Ogle, Roy; Botchwey, Edward

    2008-04-01

    The rational design of biomimetic structures for the regeneration of damaged or missing tissue is a fundamental principle of tissue engineering. Multiple variables must be optimized, ranging from the scaffold type to the selection and properties of implanted cell(s). In this study, the osteogenic potential of a novel stem cell was analyzed on biodegradable poly(lactic-co-glycolic acid) (PLGA) biomaterials as a step toward creating new cell-materials constructs for bony regeneration. Dura mater stem cells (DSCs), isolated from rat dura mater, were evaluated and compared to bone marrow stem cells (BMSCs) for proliferative and differentiative properties in vitro. Experiments were carried out on both tissue culture plastic (TCP) and 2D planar films of PLGA. Proliferation of DSCs on both TCP and PLGA films increased over 21 days. Positive fold inductions in all five bone marker genes were observed at days 7, 14, 21 in all experimental samples compared with day 0 controls. DSCs demonstrated greater cell coverage and enhanced matrix staining on 2D PLGA films when compared with BMSCs. These cells can be isolated and expanded in culture and can subsequently attach, proliferate, and differentiate on both TCP and PLGA films to a greater extent than BMSCs. This suggests that DSCs are promising for cell-based bone tissue engineering therapies, particularly those applications involving regeneration of cranial bones. Copyright 2007 Wiley Periodicals, Inc.

  18. Electromagnetic properties of a modular MHD thruster

    NASA Astrophysics Data System (ADS)

    Kom, C. H.; Brunet, Y.

    1999-04-01

    The magnetic field of an annular MHD thruster made of independent superconducting modules has been studied with analytical and numerical methods. This configuration allows to obtain large magnetized volumes and high induction levels with rapidly decreasing stray fields. When some inductors are out of order, the thruster remains still operational, but the stray fields increase in the vicinity of the failure. For given structural materials and superconductors, it is possible to determine the size of the conductor in order to reduce the electromagnetic forces and the peak field supported by the conductors. For an active field of 10 T in a 6 m ray annular active channel of a thruster with 24 modules, the peak field is exactly 15.6 T in the Nb3Sn conductors and the structure has to sustain 10^8 N/m forces. The necessity to place some magnetic or superconducting shield is discussed, particularly when the thruster is in a degraded regime. Nous présentons une étude analytique et numérique du champ magnétique d'un propulseur MHD naval annulaire, constitué de secteurs inducteurs supraconducteurs. Cette configuration nécessite des champs magnétiques élevés dans des volumes importants, et permet une décroissance rapide des champs de fuite. Lorsque quelques inducteurs sont en panne, le propulseur reste toujours opérationnel, mais les champs de fuite sont importants aux environs des modules hors service. Étant donné un matériau supraconducteur, il est possible de déterminer la forme des inducteurs dans le but de réduire à la fois les forces électromagnétiques et le surchamp supporté par le bobinage. Pour un propulseur annulaire constitué de 24 modules inducteurs, et un champ actif de 10 T au centre de la partie active du canal (r = 6 m) on obtient avec du Nb3Sn un champ maximun sur le conducteur de 15,5 T et la structure supporte une force de 10^8 N/m. De plus, la nécessité de placer des écrans magnétique ou supraconducteur en régime dégradé (mise

  19. Méthodes de type éléments finis pour le calcul des champs électriques et magnétiques en électroencéphalographie et magnétoencéphalographie

    NASA Astrophysics Data System (ADS)

    Guérin, Christophe; Marin, Gildas; Garnero, Line; Meunier, Gérard

    1997-12-01

    So as to compute the electric potential and the flux density generated by the electrical activity of the brain, numerical methods based on the Finite Element Method have been developed. These methods, which can treat realistic head models and can take into account anisotropy of conductivity, for instance in the skull, are presented. Then two numerical examples are described: a spherical model and a realistic head model. Afin de calculer le potentiel électrique et l'induction créés par l'activité électrique du cerveau, nous avons développé des méthodes utilisant la Méthode des Éléments Finis. Ces méthodes, qui peuvent s'appliquer à des modèles réalistes de tête et qui permettent de tenir compte de la conductivité anisotrope de certains tissus comme l'os, sont présentées. Puis deux exemples numériques sont décrits : un modèle de sphères concentriques et un modèle réaliste de tête.

  20. Fabrication of Titanium Oxide-Based Composites by Reactive SPS Sintering and Their Thermoelectric Properties

    NASA Astrophysics Data System (ADS)

    Fuda, K.; Shoji, T.; Kikuchi, S.; Kunihiro, Y.; Sugiyama, S.

    2013-07-01

    Titanium oxide-based composites containing (1) Nb, (2) Nb and Sr, and (3) Sr and La were fabricated by a combination of wet processing and reactive spark plasma sintering in which the metal oxide components were reduced by reaction with titanium nitride. If only TiO2 was used as the starting material, several Magneli-type phases of oxygen-deficient titanium oxides were obtained. When mixed with Nb ions with Ti:Nb = 0.9:0.1, microsegregation of Nb ions was observed (case 1). If Sr was added, a perovskite, SrTiO3 (STO) phase occurred (case 2), which contained La ions in the case of La addition (case 3). The sintered compacts consisted largely of grains of about 1 μm in size. In the case of Ti-Nb combination (case 1), a unique stripe pattern also appeared inside the grains. The electrical conductivity increased monotonically with increasing temperature in the case of the pure Magneli phases and the Nb-containing composite, whereas bow-shaped temperature dependences with a maximum were observed in the case of the composites containing STO phases. The Seebeck coefficients were commonly negative, and the absolute values increased with temperature. The thermal conductivity was between 2 W m-1 K-1 and 4 W m-1 K-1 in the temperature range from room temperature to 800°C. A maximum ZT of 0.34 was achieved at 800°C (case 2).

  1. Is IQ in Childhood Associated with Suicidal Thoughts and Attempts? Findings from the Mater University Study of Pregnancy and Its Outcomes

    ERIC Educational Resources Information Center

    Alati, Rosa; Gunnell, David; Najman, Jake; Williams, Gail; Lawlor, Debbie

    2009-01-01

    This study explores associations of IQ at age 14 with adult symptoms of suicidal thoughts and attempts at age 21. Analysis was based on the Mater University Study of Pregnancy and its outcomes, an Australian prospective birth cohort study started in Brisbane Australia in 1981. We assessed associations with suicide thoughts, plans, and attempts. We…

  2. Low complication rate of sellar reconstruction by artificial dura mater during endoscopic endonasal transsphenoidal surgery.

    PubMed

    Ye, Yuanliang; Wang, Fuyu; Zhou, Tao; Luo, Yi

    2017-12-01

    To evaluate effect of sellar reconstruction during pituitary adenoma resection surgery by the endoscopic endonasal transsphenoidal approach using artificial cerebral dura mater patch.This was a retrospective study of 1281 patients who underwent endoscopic transsphenoidal resection for the treatment of pituitary adenomas between December 2006 and May 2014 at the Neurosurgery Department of the People's Liberation Army General Hospital. The patients were classified into 4 grades according to intraoperative cerebrospinal fluid (CSF) leakage site. All patients were followed up for 3 months by telephone and outpatient visits.One thousand seventy three (83.7%) patients underwent sellar reconstruction using artificial dura matter patched outside the sellar region (method A), 106 (8.3%) using artificial dura matter patched inside the sellar region (method B), and 102 (8.0%) using artificial dura matter and a mucosal flap (method C). Method A was used for grade 0-1 leakage, method B for grade 1 to 2 leakage, and method C for grade 2 to 3 leakage. During the 3-month follow-up, postoperative CSF leakage was observed in 7 patients (0.6%): 2 among patients who underwent method B (1.9%) and 5 among those who underwent method C (4.9%). Meningitis was diagnosed in 13 patients (1.0%): 2 among patients who underwent method A (0.2%), 4 among those who underwent method B (3.8%), and 7 among those who underwent method C (6.7%).Compared with other reconstruction methods, sellar reconstruction surgery that only use artificial dura mater as repair material had a low rate of complications. Copyright © 2017 The Authors. Published by Wolters Kluwer Health, Inc. All rights reserved.

  3. Force Measurements on Plasma Actuators Using Phase-locked Particle Image Velocimetry

    DTIC Science & Technology

    2015-05-01

    structured as follows. In Section 2, the details of the experimental apparatus and procedures, including the plasma actuator, the electronics used for...was placed ing the plasm wire gauge ( tage probe. l, which wa a ratio of 2 on signal wa he excitation ft) and the di DRDC-RDD on the force a...a Trek Mod t 2.5 kHz an e plasma cope (right). 1 a t el d DRDC F Durin using metho magn plasm -RDDC-2015 igure 4: Sche Figu g each exper the

  4. Conference Proceedings on Visual Protection and Enhancement Held in Athens, Greece on 22-24 April 1985

    DTIC Science & Technology

    1985-12-01

    mounted in one NVG barrel, which he styles an NVG head up display (HUD). A similar result could be obtained by using NVGs already equipped with beam...extrietcr. La perception du relief ne peut se faire par mise en eu de le stroscopie seuls los facteur corticaux da cotta parcaption 5O. utili’c4s...r6alit,ý op6rationnelle, contr616 at idantique pour tous los sujets. Pour ce faire , dos prises do vues ont 6t r~alis~es au magn~toscope lors do vol

  5. A NMR (Nuclear Magnetic Resonance) Study of the Molecular Interactions and Dynamic Behavior in Polymer-Diluent Blends in the Solid State

    DTIC Science & Technology

    1988-07-25

    The same time- tributions. As shown by Kaplan and Garroway 2 eq 1 can saving scheme can be adopted for r’s at the shorter 7 end be recast in the form...Foundation 1980, 13, 1127. EIiuipment Grant No. CHE 77-09059, of National Science (12) Kaplan, J. L.; Garroway , A. N. J. Magn. Resun. 1982, 49. 464...North Holland: New York, 1985; Vol. 12. 3. Kaplan, J.I., Garroway , A.M., J. Hag. Res. 1982, 49, 1 464. 4. Roy, A.K., Jones, A.A., Inglefield, P.T

  6. Daily Magnetograms for 1982 from the AFGL (Air Force Geophysics Laboratory) Network.

    DTIC Science & Technology

    1985-03-01

    who as a IN high-school student, carried out much of the computer work that produced the A edited data shown in these plots and who lost his life in...34,. . .. . . . . .. .. .. .. . . . . .. . . . . . .. . . . . .. . ... .. . . .... .. .. .... *... II * .- eeee OM 04eO 66 eeee OMe IM 12 14e9 1600 18 2M 22 66 .’.W 06 A 82 (DAY 82.M6) UIVERSAL TIrE WGL...lit’ 54437 1 S4571 55315 S32Sg9. .5 42871 F, .. . . . . . . .- - - 88 MW 82 (DAY 82.128) UIVERSAL TIME AFGL MAGN~ETEER PETUFlJ 135

  7. [Headache as a manifestation of SAPHO syndrome with a lesion extending to the dura mater, parietal bone, and temporal muscle].

    PubMed

    Uematsu, Miho; Tobisawa, Shinsuke; Nagao, Masahiro; Matsubara, Shiro; Mizutani, Toshio; Shibuya, Makoto

    2012-01-01

    A 50-year-old woman with a history of palmoplantar pustulosis, femur osteomyelitis, and sterno-costo-clavicular hyperostosis presented with a chronic severe left temporal headache that had progressed during the previous year. Her CRP level was elevated. Cranial images showed Gadolinium-enhancement of the left temporal muscle, left parietal bone and dura mater. (99m)Tc-HMDP scintigram showed increased uptake in the left parietal bone, left sterno-costo-clavicular joint, right femoral head and intervertebral joints. Biopsy of the lesion demonstrated 1) proliferation of connective tissue in both perimysium and endomysium of the temporal muscle with mild inflammatory cell infiltration within the interstitium, 2) marked infiltration of granulocytes to the bone marrow of the parietal bone, 3) necrosis and moderate fibrosis in the interstitium with inflammatory cell infiltration in the parietal bone, and 4) moderate fibrosis and slight infiltration of inflammatory cells in the dura mater. The patient was diagnosed with a cranial lesion of synovitis-acne-pustulosis-hyperostosis-osteitis (SAPHO) syndrome. There was a moderate response to treatment with intravenous steroid pulse therapy and subsequent methotrexate. In a case of headache accompanied by inflammatory response, palmoplantar pustulosis and joint lesions such as hyperostosis, the possibility of a rare cranial manifestation of SAPHO syndrome should be considered.

  8. [Electron microscopy of the lesions produced in the human dura mater by Quincke beveled and Whitacre needles].

    PubMed

    Reina, M A; López-García, A; de Andrés-Ibáñez, J A; Dittmann, M; Cascales, M R; del Caño, M C; Daneri, J; Zambrano, O

    1997-02-01

    Comparisons of Quincke needles and non traumatic "pencil point" needles in recent years have reported lower rates of post dural puncture headache using the later type. Our new understanding of the morphology of the human dura mater motivated us to study dural lesions caused by the Whitacre 25 G and Quincke 26 G needles, using scanning electron microscopy with the aim of determining whether there is an anatomic basis for the different outcomes. The dura mater from three fresh cadavers of individuals aged 65, 70 and 72 years were punctured 40 times at an angle of 90 degrees each time. The Whitacre 25 G needle was used for 20 punctures and the Quincke 26 G needle was used for the other 20. Half the punctures were performed with the bevel in the parallel alignment and the other half with the bevel perpendicular to the spinal column. Fifteen min after causing the punctures, specimens were fixed in solutions of glutaraldehyde phosphate buffer and dehydrated in acetone. After critical point removal of the acetone, after the specimens were treated with carbon and metallized with gold. The lesions were examined externally and internally and expressed as the ratio of area of lesion to diameter of the needle that had caused them. Whitacre needle: each lesion consisted in the superimposition of multiple damaged layers that started to close individually. After 15 min the outermost layers were 90% closed and the innermost ones had closed entirely. Layers in the arachnoid surface of the dura mater had closed from 86 to 88%, while deeper layers in the thick part had closed 97 to 98%. Quincke needle: lesions were V-shaped or half-moon shaped, much like the opening formed by a can opener, on both the external and internal surfaces. Alignment of the bevel of the needle parallel to the spinal column did not lead to a different shape of puncture. After 15 min the lesions had closed 94 to 95% on the epidural surface and 95 to 96% on the arachnoid side, a difference attributable to the

  9. TiO2--a prototypical memristive material.

    PubMed

    Szot, K; Rogala, M; Speier, W; Klusek, Z; Besmehn, A; Waser, R

    2011-06-24

    Redox-based memristive switching has been observed in many binary transition metal oxides and related compounds. Since, on the one hand, many recent reports utilize TiO(2) for their studies of the memristive phenomenon and, on the other hand, there is a long history of the electronic structure and the crystallographic structure of TiO(2) under the impact of reduction and oxidation processes, we selected this material as a prototypical material to provide deeper insight into the mechanisms behind memristive switching. In part I, we briefly outline the results of the historical and recent studies of electroforming and resistive switching of TiO(2)-based cells. We describe the (tiny) stoichiometrical range for TiO(2 - x) as a homogeneous compound, the aggregation of point defects (oxygen vacancies) into extended defects, and the formation of the various Magnéli phases. Furthermore, we discuss the driving forces for these solid-state reactions from the thermodynamical point of view. In part II, we provide new experimental details about the hierarchical transformation of TiO(2) single crystals into Magnéli phases, and vice versa, under the influence of chemical, electrical and thermal gradients, on the basis of the macroscopic and nanoscopic measurements. Those include thermogravimetry, high-temperature x-ray diffraction (XRD), high-temperature conductivity measurements, as well as low-energy electron diffraction (LEED), x-ray photoelectron spectroscopy (XPS), and LC-AFM (atomic force microscope equipped with a conducting tip) studies. Conclusions are drawn concerning the relevant parameters that need to be controlled in order to tailor the memristive properties.

  10. Measuring the labeling efficiency of pseudocontinuous arterial spin labeling.

    PubMed

    Chen, Zhensen; Zhang, Xingxing; Yuan, Chun; Zhao, Xihai; van Osch, Matthias J P

    2017-05-01

    Optimization and validation of a sequence for measuring the labeling efficiency of pseudocontinuous arterial spin labeling (pCASL) perfusion MRI. The proposed sequence consists of a labeling module and a single slice Look-Locker echo planar imaging readout. A model-based algorithm was used to calculate labeling efficiency from the signal acquired from the main brain-feeding arteries. Stability of the labeling efficiency measurement was evaluated with regard to the use of cardiac triggering, flow compensation and vein signal suppression. Accuracy of the measurement was assessed by comparing the measured labeling efficiency to mean brain pCASL signal intensity over a wide range of flip angles as applied in the pCASL labeling. Simulations show that the proposed algorithm can effectively calculate labeling efficiency when correcting for T1 relaxation of the blood spins. Use of cardiac triggering and vein signal suppression improved stability of the labeling efficiency measurement, while flow compensation resulted in little improvement. The measured labeling efficiency was found to be linearly (R = 0.973; P < 0.001) related to brain pCASL signal intensity over a wide range of pCASL flip angles. The optimized labeling efficiency sequence provides robust artery-specific labeling efficiency measurement within a short acquisition time (∼30 s), thereby enabling improved accuracy of pCASL CBF quantification. Magn Reson Med 77:1841-1852, 2017. © 2016 International Society for Magnetic Resonance in Medicine Magn Reson Med 77:1841-1852, 2017. © 2016 International Society for Magnetic Resonance in Medicine. © 2016 International Society for Magnetic Resonance in Medicine.

  11. A Magnetic-Field Guided Interface Coassembly Approach to Magnetic Mesoporous Silica Nanochains for Osteoclast-Targeted Inhibition and Heterogeneous Nanocatalysis.

    PubMed

    Wan, Li; Song, Hongyuan; Chen, Xiao; Zhang, Yu; Yue, Qin; Pan, Panpan; Su, Jiacan; Elzatahry, Ahmed A; Deng, Yonghui

    2018-06-01

    1D core-shell magnetic materials with mesopores in shell are highly desired for biocatalysis, magnetic bioseparation, and bioenrichment and biosensing because of their unique microstructure and morphology. In this study, 1D magnetic mesoporous silica nanochains (Fe 3 O 4 @nSiO 2 @mSiO 2 nanochain, Magn-MSNCs named as FDUcs-17C) are facilely synthesized via a novel magnetic-field-guided interface coassembly approach in two steps. Fe 3 O 4 particles are coated with nonporous silica in a magnetic field to form 1D Fe 3 O 4 @nSiO 2 nanochains. A further interface coassembly of cetyltrimethylammonium bromide and silica source in water/n-hexane biliquid system leads to 1D Magn-MSNCs with core-shell-shell structure, uniform diameter (≈310 nm), large and perpendicular mesopores (7.3 nm), high surface area (317 m 2 g -1 ), and high magnetization (34.9 emu g -1 ). Under a rotating magnetic field, the nanochains with loaded zoledronate (a medication for treating bone diseases) in the mesopores, show an interesting suppression effect of osteoclasts differentiation, due to their 1D nanostructure that provides a shearing force in dynamic magnetic field to induce sufficient and effective reactions in cells. Moreover, by loading Au nanoparticles in the mesopores, the 1D Fe 3 O 4 @nSiO 2 @mSiO 2 -Au nanochains can service as a catalytically active magnetic nanostirrer for hydrogenation of 4-nitrophenol with high catalytic performance and good magnetic recyclability. © 2018 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  12. Constraining dark matter annihilation with the isotropic γ-ray background: Updated limits and future potential

    NASA Astrophysics Data System (ADS)

    Bringmann, Torsten; Calore, Francesca; Di Mauro, Mattia; Donato, Fiorenza

    2014-01-01

    The nature of the isotropic γ-ray background (IGRB) measured by the Large Area Telescope (LAT) on the Fermi γ-ray space telescope (Fermi) remains partially unexplained. Non-negligible contributions may originate from extragalactic populations of unresolved sources such as blazars, star-forming galaxies or galactic millisecond pulsars. A recent prediction of the diffuse γ-ray emission from active galactic nuclei (AGN) with a large viewing angle with respect to the line of sight has demonstrated that this faint but numerous population is also expected to contribute significantly to the total IGRB intensity. A more exotic contribution to the IGRB invokes the pair annihilation of dark matter (DM) weakly interacting massive particles (WIMPs) into γ rays. In this work, we evaluate the room left for galactic DM at high latitudes (>10∘) by including photons from both prompt emission and inverse Compton scattering, emphasizing the impact of the newly discovered contribution from misaligned AGN (MAGN) for such an analysis. Summing up all significant galactic and extragalactic components of the IGRB, we find that an improved understanding of the associated astrophysical uncertainties is still mandatory to put stringent bounds on thermally produced DM. On the other hand, we also demonstrate that the IGRB has the potential to be one of the most competitive future ways to test the DM WIMP hypothesis, once the present uncertainties are even slightly reduced. In fact, if MAGN contribute even at 90% of the maximal level consistent with our current understanding, thermally produced WIMPs would be severely constrained as DM candidates for masses up to several TeV.

  13. Improvements in Diagnostic Accuracy with Quantitative Dynamic Contrast-Enhanced MRI

    DTIC Science & Technology

    2013-12-01

    11), and time to peak enhancement (TTP) were also determined for each lesion. TTP was calculated from the EMM parameters – i.e. the time at which...rate (α) (min-1) 0.54 ± 0.45 0.62 ± 0.64 14%±76% 51% ± 55% Washout rate (β) (min-1) 0.06 ± 0.03 0.03 ± 0.03 -11%±84% 67% ± 46% Time to peak ...radiofrequency field. Magn. Reson. Med. 2007;57:192– 200. doi: 10.1002/ mrm .21120. 7. Nehrke K. On the steady-state properties of actual flip angle imaging (AFI

  14. Paraplégie compliquant une plaie abdominale antérieure par arme blanche

    PubMed Central

    Elahmadi, Brahim; Awab, Almahdi; El Moussaoui, Rachid; El Hijri, Ahmed; Azzouzi, Abderrahim; Alilou, Mustapha

    2015-01-01

    Les traumatismes médullaires sont des complications rares des plaies abdominales antérieures par arme blanche. Son diagnostic est difficile parfois retardé. L'imagerie par résonance magnétique reste l'examen de choix. Le traitement dépend du tableau clinique et de la gravité de la souffrance médullaire. Le pronostic est corrélé à l’étendue et à la nature de la lésion médullaire. Nous rapportons un cas exceptionnel d'un traumatisme médullaire chez une patiente victime d'une plaie abdominale antérieure par arme blanche. PMID:25995808

  15. Dinámica de pulsares jóvenes

    NASA Astrophysics Data System (ADS)

    Allen, M. P.; Horvath, J. E.

    La observación detallada de los pulsos en varios pulsares jóvenes (τ < 105 yr) permitió detectar varios aumentos en la frecuencia de emisión gliches con cambios permanentes en Δ {˙ Ω} / {˙ Ω}. A través de las ecuaciones de movimiento se investiga, utilizando parametrizaciones simples, la hipótesis de que el ángulo entre Ω y el dipolo magnético M sea responsable de ese comportamiento. Se derivan curvas analíticas para la evolución de Ω (t) y se estudia la posibilidad de describir un conjunto de observables (incluyendo el braking index n) con estos modelos.

  16. Update: Dura Mater Graft-Associated Creutzfeldt-Jakob Disease - Japan, 1975-2017.

    PubMed

    Ae, Ryusuke; Hamaguchi, Tsuyoshi; Nakamura, Yosikazu; Yamada, Masahito; Tsukamoto, Tadashi; Mizusawa, Hidehiro; Belay, Ermias D; Schonberger, Lawrence B

    2018-03-09

    Creutzfeldt-Jakob disease (CJD) is a fatal neurodegenerative disorder that, according to the most well accepted hypothesis (1), is caused by replicating, transmissible, abnormal forms of a host-encoded prion protein (prions). Most CJD cases occur spontaneously (sporadic CJD) or are inherited (genetic CJD). Iatrogenic CJD can occur after exposure to prion-contaminated instruments or products in medical/surgical settings. Cadaveric dura mater graft-associated CJD (dCJD) accounts for a common form of iatrogenic CJD. This report summarizes the epidemiologic features of 154 cases of dCJD identified in Japan during 1975-2017; these cases account for >60% of dCJD cases reported worldwide (1,2). The unusually high prevalence of dCJD in Japan was first reported in 1997 (3). In 2008, a single brand of graft (Lyodura [B. Braun Melsungen AG, Melsungen, Germany]), frequently used as a patch in neurosurgical procedures, was identified as the probable vehicle of transmission (4). No international recall of the implicated Lyodura occurred, the product had a relatively long shelf life, and the grafts were used frequently in Japanese patients with non-life-threatening conditions (4,5). Since 2008, additional cases have been ascertained, reflecting the identification of previously missed cases and the occurrence of new cases with longer latency periods (interval from exposure to symptom onset) for dCJD (up to 30 years), underscoring the importance of maintaining surveillance for dCJD.

  17. Investigation of in vitro Hydrophilic and Hydrophobic Dual Drug Release from Polymeric Films Produced by Sodium alginate-MaterBi® Drying Emulsions.

    PubMed

    Setti, Chiara; Suarato, Giulia; Perotto, Giovanni; Athanassiou, Athanassia; Bayer, Ilker S

    2018-06-18

    Emulsions are known to be effective carriers of hydrophobic drugs, and particularly injectable emulsions have been successfully implemented for in vivo controlled drug release. Recently, high internal phase emulsions have also been used to produce porous polymeric templates for pharmaceutical applications. However, emulsions containing dissolved biopolymers both in the oil and water phases are very scarce. In this study, we demonstrate such an emulsion, in which the oil phase contains a hydrophobic biodegradable polymer, MaterBi ® , and the water phase is aqueous sodium alginate dispersion. The two phases were emulsified simply by ultrasonic processing without any surfactants. The emulsions were stable for several days and were dried into composite solid films with varying MaterBi ® /alginate fractions. The films were loaded with two model drugs, a hydrophilic eosin-based cutaneous antiseptic and the hydrophobic curcumin. Drug release capacity of the films was investigated in detail, and controlled release of each model drug was achieved either by tuning the polymer fraction in the films during emulsification or by crosslinking sodium alginate fraction of the films by calcium salt solution immersion. The emulsions can be formulated to carry either a single model drug or both drugs depending on the desired application. Films demonstrate excellent cell biocompatibility against human dermal fibroblast, adult cells. Copyright © 2018. Published by Elsevier B.V.

  18. Perpendicular recording media for hard disk drives

    NASA Astrophysics Data System (ADS)

    Piramanayagam, S. N.

    2007-07-01

    Perpendicular recording technology has recently been introduced in hard disk drives for computer and consumer electronics applications. Although conceptualized in the late 1970s, making a product with perpendicular recording that has competing performance, reliability, and price advantage over the prevalent longitudinal recording technology has taken about three decades. One reason for the late entry of perpendicular recording is that the longitudinal recording technology was quite successful in overcoming many of its problems and in staying competitive. Other reasons are the risks, problems, and investment needed in making a successful transition to perpendicular recording technology. Iwasaki and co-workers came up with many inventions in the late 1970s, such as single-pole head, CoCr alloy media with a perpendicular anisotropy, and recording media with soft magnetic underlayers [S. Iwasaki and K. Takemura, IEEE Trans. Magn. 11, 1173 (1975); S. Iwasaki and Y. Nakamura, IEEE Trans. Magn. 14, 436 (1978); S. Iwasaki, Y. Nakamura, and K. Ouchi, IEEE Trans. Magn. 15, 1456 (1979)]. Nevertheless, the research on perpendicular recording media has been intense only in the past five years or so. The main reason for the current interest comes from the need to find an alternative technology to get away from the superparamagnetic limit faced by the longitudinal recording. Out of the several recording media materials investigated in the past, oxide based CoCrPt media have been considered a blessing. The media developed with CoCrPt-oxide or CoCrPt -SiO2 have shown much smaller grain sizes, lower noise, and larger thermal stability than the perpendicular recording media of the past, which is one of the reasons for the success of perpendicular recording. Moreover, oxide-based perpendicular media have also overtaken the current longitudinal recording media in terms of better recording performance. Several issues that were faced with the soft underlayers have also been solved by the

  19. Impact of neoadjuvant therapy in downstaging of lower rectal adenocarcinoma and the role of pelvic magnetic resonance in staging.

    PubMed

    Magri, Karina Dagre; Bin, Fang Chia; Formiga, Fernanda Bellotti; Manzione, Thiago da Silveira; Gomes, Caroline Merci Caliari de Neves; Candelári, Paulo de Azeredo Passos; Ortiz, Jorge Alberto; Klug, Wilmar Artur; Mandia, José; Capelhuchnik, Peretz

    2016-01-01

    to evaluate the effect of neoadjuvant therapy on the stage (TNM) of patients with rectal adenocarcinoma and validate the use of MRI as a method of determining locoregional stage. we conducted a retrospective study of 157 patients with lower rectum adenocarcinoma, whom we divided into two groups: Group 1, 81 patients (52%) who had undergone surgical treatment initially, with the purpose to analyze the accuracy of locoregional staging by pelvic magnetic resonance imaging throug the comparison of radiological findings with pathological ones; Group 2, 76 patients (48%), who had been submitted to neoadjuvant therapy (chemotherapy and radiation) prior to definitive surgical treatment, so as to evaluate its effects on the stage by comparing clinical and radiological findings with pathology. In group 1, the accuracy of determining tumor depth (T) and lymph node involvement (N) was 91.4% and 82.7%, respectively. In group 2, neoadjuvant therapy decreased the T stage, N stage and TNM stage in 51.3%, 21% and 48.4% of cases, respectively. neoadjuvant therapy in patients with rectal adenocarcinoma is effective in decreasing disease stage, and pelvic magnetic resonance imaging is effective for locoregional staging. avaliar o efeito da terapia neoadjuvante, nos pacientes portadores de adenocarcinoma de reto, sobre o estádio (TNM) e validar o emprego da ressonância magnética como método de determinação do estádio locorregional. estudo retrospectivo de 157 pacientes com diagnóstico de adenocarcinoma de reto baixo, que foram divididos em dois grupos: Grupo 1, 81 pacientes (52%), submetidos ao tratamento cirúrgico de princípio, cuja finalidade foi analisar a acurácia da determinação do estádio locorregional pela ressonância magnética da pelve, através da comparação entre os achados radiológicos e os achados anatomopatológicos; Grupo 2, 76 pacientes (48%), encaminhados à terapia neoadjuvante (quimioterapia e radioterapia), antes do tratamento cirúrgico definitivo

  20. Sign and magnitude scaling properties of heart rate variability in patients with end-stage renal failure: Are these properties useful to identify pathophysiological adaptations?

    NASA Astrophysics Data System (ADS)

    Lerma, Claudia; Echeverría, Juan C.; Infante, Oscar; Pérez-Grovas, Héctor; González-Gómez, Hortensia

    2017-09-01

    The scaling properties of heart rate variability data are reliable dynamical features to predict mortality and for the assessment of cardiovascular risk. The aim of this manuscript was to determine if the scaling properties, as provided by the sign and magnitude analysis, can be used to differentiate between pathological changes and those adaptations basically introduced by modifications of the mean heart rate in distinct manoeuvres (active standing or hemodialysis treatment, HD), as well as clinical conditions (end stage renal disease, ESRD). We found that in response to active standing, the short-term scaling index (α1) increased in healthy subjects and in ESRD patients only after HD. The sign short-term scaling exponent (α1sign) increased in healthy subjects and ESRD patients, showing a less anticorrelated behavior in active standing. Both α1 and α1sign did show covariance with the mean heart rate in healthy subjects, while in ESRD patients, this covariance was observed only after HD. A reliable estimation of the magnitude short-term scaling exponent (α1magn) required the analysis of time series with a large number of samples (>3000 data points). This exponent was similar for both groups and conditions and did not show covariance with the mean heart rate. A surrogate analysis confirmed the presence of multifractal properties (α1magn > 0.5) in the time series of healthy subjects and ESDR patients. In conclusion, α1 and α1sign provided insights into the physiological adaptations during active standing, which revealed a transitory impairment before HD in ESRD patients. The presence of multifractal properties indicated that a reduced short-term variability does not necessarily imply a declined regulatory complexity in these patients.

  1. Properties of TEM standing waves with E||B

    NASA Astrophysics Data System (ADS)

    Zaghloul, H.; Buckmaster, H. A.

    This paper summarizes the known properties of E∥B TEM standing waves and shows that for such waves (i) E and B cannot be linearly polarized, (ii) E ≠ αB where α is a constant (iii) it is impossible to find a Lorentz frame where E>B, (iv) direction of the propagation vector cannot be inferred from the fields at one point of the space, (v) their behaviour under Lorentz, parity, time-reversal and gauge transformations is proper, (vi) both Lorentz invariants E2 - B2 and E·B are nonzero, (vii) the magnetic helicity may be nonzero, (viii) the magnetic field may be force-free, and (ix) kμFμv ≠ 0. It also shows how electromagnetic waves can be classified using Lorentz invariants. Cet article résume les qualités connues des ondes stationnaires E∥B TEM et montre que pour des ondes parallèles (i) E et B ne peuvent pas être polarisées linéairement, (ii) E ≠ αB où a est une constante, (iii) il est impossible de trouver une construction de Lorentz où E>B, (iv) la direction de propagation d'un vecteur ne peut pas être déduite des opérations à un point d'intervalle, (v) leur conduite sous Lorentz, parité, temps inverse et transformations de jauge est propre, (vi) les deux invariants de Lorentz E2 - B2 et E·B sont non nulles (vii) l'hélice magnétique peut être non nulle (viii) l'opération magnétique peut être de force libre et (ix) KμFμ v ≠ 0. Ceci montre aussi comment les ondes électromagnétiques peuvent être classifiées, en employant les invariants de Lorentz.

  2. Analysis of argentinated peptide complexes using matrix-assisted laser desorption/ionization time-of-flight mass spectrometry: Peptide = oxytocin, arg(8) -vasopressin, bradykinin, bombesin, somatostatin, neurotensin.

    PubMed

    Gupta, Shyam L; Dhiman, Vikas; Jayasekharan, T; Sahoo, N K

    2016-06-15

    The increased use of silver nanoparticles (AgNPs) for various biological applications, and over-expression of various peptide receptors in different tumors/cancer cells, necessitate the need for dedicated investigations on the intrinsic binding ability of Ag with various biologically important peptides for better understanding of AgNPs-peptide interactions and for the future development of contrasting agents as well as drugs for imaging/biomedical applications. The [M+(Ag)n ](+) complexes are prepared and characterized using matrix-assisted laser desorption/ionization time-of-flight mass spectrometry (MALDI-TOFMS). Silver complexes of the peptides [M+(Ag)n ](+) , where M = oxytocin, arg(8) -vasopressin, bradykinin, bombesin, somatostatin, and neurotensin, have been investigated for their intrinsic Ag(+) -binding ability. Unusual binding of up to seven Ag(+) with these small peptides is observed. The mass spectra show n = 1-5 for bombesin and somatostatin, n = 1-6 for bradykinin and arg(8) -vasopressin, and n = 1-7 for oxytocin and neurotensin. In addition, oxytocin and arg(8) -vasopressin show the formation of dimers and their complexes [M2 +(Ag)n ](+) with n = 1-8 and n = 1-5, respectively. The possible amino acid residues responsible for Ag(+) binding in each peptide have been identified on the basis of density functional theory (DFT)-calculated binding energy values of Ag(+) towards individual amino acids. Mass spectrometric evidence indicates that the peptides, viz., oxytocin, arg(8) -vasopressin, bradykinin, bombesin, somatostatin, and neurotensin, show greater affinity for Ag(+) . Hence, they may be used as carriers for AgNPs in targeted drug delivery as well as an alternative for iodinated contrasting agents in dual energy X-ray imaging techniques. Radio-labeled Ag with these peptides can also be used in radio-pharmaceuticals for diagnostic and therapeutic applications. Copyright © 2016 John Wiley & Sons, Ltd. Copyright © 2016 John Wiley & Sons, Ltd.

  3. Élaboration et performances de matériaux supraconducteurs {YBa_2Cu_3O_7} massifs texturés de taille croissante

    NASA Astrophysics Data System (ADS)

    Chaud, X.; Gautier-Picard, P.; Beaugnon, E.; Porcar, L.; Bourgault, D.; Tournier, R.; Erraud, A.; Tixador, P.

    1998-03-01

    Industrial applications of the bulk superconducting YBa_2Cu_3O_7 material imply to control the growth of large oriented monodomains in samples of big size (several centimeters). The laboratory EPM-Matformag is committed to produce such materials according to three different methods (zone melting, solidification controlled by a magnetic field, crystal growth from a seed). The results obtained show that it is possible by such methods to elaborate a material with high performances at the centimeter scale and to produce it in series. The availability of such materials allows the measure of physical properties on a large scale and the testing of prototypes for cryo-electrotechnical applications (magnetic bearing, flywheel, coupling device, current lead...). Les applications industrielles des matériaux supraconducteurs massifs YBa_2Cu_3O_7 impliquent de contrôler la croissance de larges monodomaines orientés dans des échantillons de grande taille (plusieurs centimètres). Le laboratoire EPM-Matformag s'est appliqué à produire de tels matériaux selon trois techniques différentes (fusion de zone, solidification contrôlée sous champ magnétique, croissance cristalline à partir d'un germe). Les résultats obtenus montrent qu'il est possible par de telles techniques d'obtenir un matériau performant à l'échelle des centimètres et de le produire en série. La disponibilité de tels matériaux permet de mesurer des propriétés physiques à grande échelle et de tester des prototypes d'applications cryo-électrotechniques (palier magnétique, volant d'inertie, coupleur, amenée de courant, limiteur de courant...).

  4. Sign and magnitude scaling properties of heart rate variability in patients with end-stage renal failure: Are these properties useful to identify pathophysiological adaptations?

    PubMed

    Lerma, Claudia; Echeverría, Juan C; Infante, Oscar; Pérez-Grovas, Héctor; González-Gómez, Hortensia

    2017-09-01

    The scaling properties of heart rate variability data are reliable dynamical features to predict mortality and for the assessment of cardiovascular risk. The aim of this manuscript was to determine if the scaling properties, as provided by the sign and magnitude analysis, can be used to differentiate between pathological changes and those adaptations basically introduced by modifications of the mean heart rate in distinct manoeuvres (active standing or hemodialysis treatment, HD), as well as clinical conditions (end stage renal disease, ESRD). We found that in response to active standing, the short-term scaling index (α 1 ) increased in healthy subjects and in ESRD patients only after HD. The sign short-term scaling exponent (α 1sign ) increased in healthy subjects and ESRD patients, showing a less anticorrelated behavior in active standing. Both α 1 and α 1sign did show covariance with the mean heart rate in healthy subjects, while in ESRD patients, this covariance was observed only after HD. A reliable estimation of the magnitude short-term scaling exponent (α 1magn ) required the analysis of time series with a large number of samples (>3000 data points). This exponent was similar for both groups and conditions and did not show covariance with the mean heart rate. A surrogate analysis confirmed the presence of multifractal properties (α 1magn  > 0.5) in the time series of healthy subjects and ESDR patients. In conclusion, α 1 and α 1sign provided insights into the physiological adaptations during active standing, which revealed a transitory impairment before HD in ESRD patients. The presence of multifractal properties indicated that a reduced short-term variability does not necessarily imply a declined regulatory complexity in these patients.

  5. Egnos-Based Multi-Sensor Accurate and Reliable Navigation in Search-And Missions with Uavs

    NASA Astrophysics Data System (ADS)

    Molina, P.; Colomina, I.; Vitoria, T.; Silva, P. F.; Stebler, Y.; Skaloud, J.; Kornus, W.; Prades, R.

    2011-09-01

    This paper will introduce and describe the goals, concept and overall approach of the European 7th Framework Programme's project named CLOSE-SEARCH, which stands for 'Accurate and safe EGNOS-SoL Navigation for UAV-based low-cost SAR operations'. The goal of CLOSE-SEARCH is to integrate in a helicopter-type unmanned aerial vehicle, a thermal imaging sensor and a multi-sensor navigation system (based on the use of a Barometric Altimeter (BA), a Magnetometer (MAGN), a Redundant Inertial Navigation System (RINS) and an EGNOS-enabled GNSS receiver) with an Autonomous Integrity Monitoring (AIM) capability, to support the search component of Search-And-Rescue operations in remote, difficult-to-access areas and/or in time critical situations. The proposed integration will result in a hardware and software prototype that will demonstrate an end-to-end functionality, that is to fly in patterns over a region of interest (possibly inaccessible) during day or night and also under adverse weather conditions and locate there disaster survivors or lost people through the detection of the body heat. This paper will identify the technical challenges of the proposed approach, from navigating with a BA/MAGN/RINS/GNSS-EGNOSbased integrated system to the interpretation of thermal images for person identification. Moreover, the AIM approach will be described together with the proposed integrity requirements. Finally, this paper will show some results obtained in the project during the first test campaign performed on November 2010. On that day, a prototype was flown in three different missions to assess its high-level performance and to observe some fundamental mission parameters as the optimal flying height and flying speed to enable body recognition. The second test campaign is scheduled for the end of 2011.

  6. Myopéricardite aiguë simulant un infarctus du myocarde: à propos d'une observation et revue de la littérature

    PubMed Central

    Bouzerda, Abdelmajid

    2015-01-01

    Le diagnostic de myopéricardite aiguë est difficile surtout quand la présentation clinique mime un syndrome coronaire aiguë. Nous rapportons l'observation d'un patient âgé de 40 ans admis pour un syndrome coronarien aiguë ST+ chez qui la coronarographie réalisée en urgence montre un réseau coronaire angio-graphiquement sain. L'imagerie par résonance magnétique (IRM) permettra d'affirmer le diagnostic d'une myopéricardite. Cette observation confirme le rôle primordial de l'IRM cardiaque chez les patients présentant une suspicion clinique de myocardite aiguë ou un tableau de SCA à coronaire saines. PMID:26491513

  7. High magnetic field behavior of NbFe2

    NASA Astrophysics Data System (ADS)

    Rauch, D.; Steinki, N.; Knafo, W.; Pfleiderer, C.; Duncan, W. J.; Grosche, F. M.; Süllow, S.

    2018-05-01

    We have carried out a high magnetic field study on single crystalline stoichiometric NbFe2, a material discussed in terms quantum criticality in itinerant ferromagnets, by means of high field resistivity experiments. Our experiments have been performed at the Laboratoire National des Champs Magnétiques Intenses in Toulouse, France. The resistivity of single crystalline NbFe2, has been investigated in external fields up to 15.5 T aligned along the c-axis in the temperature range of 1.4-55 K. The main focus of our study lies on the method to extract TN from the magnetoresistivity measurements, because TN could not be easily observed in temperature dependent resistivity for stoichiometric NbFe2.

  8. Modélisation des phénomènes électromagnétiques dans les matériaux supraconducteurs

    NASA Astrophysics Data System (ADS)

    Maslouh, M.; Bouillault, F.

    1998-03-01

    This paper describes a numerical method to determine the losses in a solid superconductor plunged in transverse magnetic field or in transport current. The model which is based on the Bean critical state, shows that the hysteretic phenomena are taken in account. Cet article présente une méthode de calcul permettant la détermination des pertes dans un matériau massif supraconducteur soumis à un champ magnétique transversal ou parcouru par un courant de transport. Le modèle, basé sur celui de l'état critique de Bean, met en évidence le caractère hystérétique des phénomènes.

  9. Birth-related expression of c-fos, c-jun and substance P mRNAs in the rat brainstem and pia mater: possible relationship to changes in central chemosensitivity.

    PubMed

    Wickström, H R; Holgert, H; Hökfelt, T; Lagercrantz, H

    1999-02-05

    In situ hybridization was used to characterize respiration-related areas of the brainstem activated around the time of birth as well as their postnatal sensitivity to CO2. Levels of mRNA corresponding to the immediate early genes (IEG), c-fos and c-jun, and of substance P precursor, ppt-A, were determined in rat fetuses (E21) and neonatal pups (1 h, 1 day and 6 days after normal birth) and after exposure to hypercapnia (12% CO2 for 1 h). Transient increases in c-fos mRNA were observed in the central chemoreceptor area of the ventral medullary surface (VMS), in the lateral reticular nucleus (LRN), in the nucleus of the solitary tract (NTS), and in the nucleus raphé pallidus (RPA) 1 h after birth. Increased expression of c-fos mRNA in the VMS could also be evoked by hypercapnia and this response was particularly pronounced 1 day after birth. On the other hand, c-jun mRNA could be detected already at E21 in the hypoglossal nucleus (XII) and LRN and these levels were not significantly altered at 1 h after birth. There was, however, an increase in the expression of c-jun mRNA in the pia mater surrounding the brainstem after birth. At 1 day after birth, c-jun mRNA levels had decreased in the LRN and pia mater, and later on (6 days after birth) in XII. Furthermore, the ppt-A mRNA level in NTS increased immediately after birth and remained high 1 and 6 days later. These results suggest that (a) the central chemoreceptor area of the VMS, as well as the NTS, LRN, RPA and pia mater are activated following birth; (b) the VMS, but not the other structures examined, can be activated immediately after birth by hypercapnia; and (c) increased expression of ppt-A mRNA may be related to the transition of respiratory control at birth. Copyright 1998 Elsevier Science B.V.

  10. The phase diagrams of iron-based superconductors: Theory and experiments

    NASA Astrophysics Data System (ADS)

    Martinelli, Alberto; Bernardini, Fabio; Massidda, Sandro

    2016-01-01

    Phase diagrams play a primary role in the understanding of materials properties. For iron-based superconductors (Fe-SC), the correct definition of their phase diagrams is crucial because of the close interplay between their crystallochemical and magnetic properties, on one side, and the possible coexistence of magnetism and superconductivity, on the other. The two most difficult issues for understanding the Fe-SC phase diagrams are: 1) the origin of the structural transformation taking place during cooling and its relationship with magnetism; 2) the correct description of the region where a crossover between the magnetic and superconducting electronic ground states takes place. Hence a proper and accurate definition of the structural, magnetic and electronic phase boundaries provides an extremely powerful tool for material scientists. For this reason, an exact definition of the thermodynamic phase fields characterizing the different structural and physical properties involved is needed, although it is not easy to obtain in many cases. Moreover, physical properties can often be strongly dependent on the occurrence of micro-structural and other local-scale features (lattice micro-strain, chemical fluctuations, domain walls, grain boundaries, defects), which, as a rule, are not described in a structural phase diagram. In this review, we critically summarize the results for the most studied 11-, 122- and 1111-type compound systems, providing a correlation between experimental evidence and theory. Les deux difficultés principales pour la compréhension des diagrammes de phase Fe-SC sont : 1) l'origine de la transformation structurelle ayant lieu pendant le refroidissement et sa relation avec le magnétisme ; 2) la description correcte de la région où survient un recouvrement entre les états fondamentaux électroniques, magnétiques et supraconducteur électronique survient. De ce fait, une définition appropriée et précise des frontières des phases structurelle

  11. Consecutive assessment of FA and ADC values of normal lumbar nerve roots from the junction of the dura mater.

    PubMed

    Miyagi, Ryo; Sakai, Toshinori; Yamabe, Eiko; Yoshioka, Hiroshi

    2015-06-27

    Diffusion weighted imaging (DWI) and diffusion tensor imaging (DTI) are widely used in the evaluation of the central nervous system and recently have been reported as a potential tool for diagnosis of the peripheral nerve or the lumbar nerve entrapment. The purpose of this study was to evaluate consecutive changes in apparent diffusion coefficient (ADC) and fractional anisotropy (FA) values of normal lumbar nerve roots from the junction of the dura mater. The lumbar spinal nerves were examined in 6 male healthy volunteers (mean age, 35 years) with no experiences of sciatica, with a 3.0-T MR unit using a five-element phased-array surface coil. DTI was performed with the following imaging parameters: 11084.6/73.7 ms for TR/TE; b-value, 800 s/mm2; MPG, 33 directions; slice thickness, 1.5 mm; and total scan time, 7 min 35 s. ADC and FA values at all consecutive points along the L4, L5 and S1 nerves were quantified on every 1.5 mm slice from the junction of the dura mater using short fiber tracking. ADC values of all L4, 5, and S1 nerve roots decreased linearly up to 15 mm from the dura junction and was constant distally afterward. ADC values in the proximal portion demonstrated S1 > L5 > L4 (p < 0.05). On the other hand, FA values increased linearly up to 15 mm from the dura junction, and was constant distally afterward. FA values in the proximal portion showed L4 > L5 > S1 (p < 0.05). Our study demonstrated that ADC and FA values of each L4, 5, and S1 at the proximal portion from the junction of the dura matter changed linearly. It would be useful to know the normal profile of DTI values by location of each nerve root so that we can detect subtle abnormalities in each nerve root.

  12. Le schwannome malin du nerf grand sciatique chez l'enfant

    PubMed Central

    Lechqar, Maryem; Elbiache, Imad; Atarraf, Karima; Bouabdellah, Youssef; Afifi, My Abderahman

    2012-01-01

    Le schwannome malin est une tumeur très rare chez l'enfant (1 à 2% des tumeurs des tissus mous), elle se développe au dépend des cellules de schwanne. Dans ce travail, les auteurs rapportent un cas de schwannome malin développé au dépend du nerf grand sciatique. La radiographie de la cuisse de face et de profil était normale. L'imagerie par résonance magnétique a identifié une lésion le long du trajet du nerf grand sciatique. La tumeur a été réséquée en totalité emportant le nerf grand sciatique. L'examen anatomo-pathologique a confirmé le diagnostic. PMID:23133710

  13. Luminescent and magnetic properties of europium compounds with cinnamic acid

    NASA Astrophysics Data System (ADS)

    Kalinovskaya, I. V.; Tkachenko, I. A.; Mirochnik, A. G.; Karasev, V. E.; Kavun, V. Ya.

    2011-03-01

    The temperature dependences of the molar magnetic susceptibility of luminescent europium compounds with cinnamic acid [Eu(Cin)3] n and Eu(Cin)3 · 2D · H2O (where Cin is the cinnamic acid anion and D is phen (1,10-phenanthroline) or dipy (2,2-dipyridyl)) were studied at temperatures from 300 to 2 K. The molar magnetic susceptibility of the compounds increased in the series Eu(Cin)3 · 2dipy · H2O < Eu(Cin)3 · 2phen · H2O < [Eu(Cin)3] n . The energy distances λlum between the 7 F 0 ground level and the 7 F 1 state in the luminescence spectra correlated well with λmagn obtained from magnetochemical data.

  14. Image formation in diffusion MRI: A review of recent technical developments

    PubMed Central

    Miller, Karla L.

    2017-01-01

    Diffusion magnetic resonance imaging (MRI) is a standard imaging tool in clinical neurology, and is becoming increasingly important for neuroscience studies due to its ability to depict complex neuroanatomy (eg, white matter connectivity). Single‐shot echo‐planar imaging is currently the predominant formation method for diffusion MRI, but suffers from blurring, distortion, and low spatial resolution. A number of methods have been proposed to address these limitations and improve diffusion MRI acquisition. Here, the recent technical developments for image formation in diffusion MRI are reviewed. We discuss three areas of advance in diffusion MRI: improving image fidelity, accelerating acquisition, and increasing the signal‐to‐noise ratio. Level of Evidence: 5 Technical Efficacy: Stage 1 J. MAGN. RESON. IMAGING 2017;46:646–662 PMID:28194821

  15. An NMR thermometer for cryogenic magic-angle spinning NMR: The spin-lattice relaxation of 127I in cesium iodide

    NASA Astrophysics Data System (ADS)

    Sarkar, Riddhiman; Concistrè, Maria; Johannessen, Ole G.; Beckett, Peter; Denning, Mark; Carravetta, Marina; al-Mosawi, Maitham; Beduz, Carlo; Yang, Yifeng; Levitt, Malcolm H.

    2011-10-01

    The accurate temperature measurement of solid samples under magic-angle spinning (MAS) is difficult in the cryogenic regime. It has been demonstrated by Thurber et al. (J. Magn. Reson., 196 (2009) 84-87) [10] that the temperature dependent spin-lattice relaxation time constant of 79Br in KBr powder can be useful for measuring sample temperature under MAS over a wide temperature range (20-296 K). However the value of T1 exceeds 3 min at temperatures below 20 K, which is inconveniently long. In this communication, we show that the spin-lattice relaxation time constant of 127I in CsI powder can be used to accurately measure sample temperature under MAS within a reasonable experimental time down to 10 K.

  16. M S MOLECULARES Rumo aos limites da miniaturiza o - (Molecular Magnets - towards the limits of miniaturization)

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Reis, Mario S; Moreira Dos Santos, Antonio F

    Por s culos, acreditou-se que o magnetismo s se manifestava em metais, como aqueles contendo ferro; hoje, a imagem mais comum de um m talvez seja a daquelas plaquinhas flex veis coladas geladeira com propagandas dos mais diversos tipos. O leitor conseguiria imaginar um material puramente org nico daqueles que formam os seres vivos como magn tico? E m s do tamanho de mol culas? fato: ambos existem. Esses novos materiais, conhecidos como magnetos moleculares, descobertos e desenvolvidos em v rios laborat rios do mundo, j re nem longa lista de aplica es, do tratamento do c ncer a refrigeradoresmore » ecol gicos, passando pela transmiss o de eletricidade sem perda de calor e a fabrica o de computadores extremamente velozes.« less

  17. Is IQ in childhood associated with suicidal thoughts and attempts? Findings from the Mater University Study of Pregnancy and its outcomes.

    PubMed

    Alati, Rosa; Gunnell, David; Najman, Jake; Williams, Gail; Lawlor, Debbie

    2009-06-01

    This study explores associations of IQ at age 14 with adult symptoms of suicidal thoughts and attempts at age 21. Analysis was based on the Mater University Study of Pregnancy and its outcomes, an Australian prospective birth cohort study started in Brisbane Australia in 1981. We assessed associations with suicide thoughts, plans, and attempts. We used two measures of IQ: the Raven's Standard Progressive Matrices and the Wide Range Achievement Test. In multivariable analyses, there was an inverse association between Raven's IQ and suicide thoughts, plans, and attempts, but no strong evidence of an association between the WRAT3 and the three suicidal items. Specific aspects of intelligence may be associated with suicidal thoughts, plans, and attempts.

  18. Lectin histochemistry and alkaline phosphatase activity in the pia mater vessels of spontaneously hypertensive rats (SHR).

    PubMed

    Szumańska, G; Gadamski, R

    1992-01-01

    Some lectins were used to study the localization of sugar residues on the endothelial cell surface in the pia mater blood vessels of control (WKY) and hypertensive rats (SHR). The lectins tested recognized the following residues: beta-D-galactosyl (Ricinus communis agglutinin 120, RCA-1), alpha-L-fucosyl (Ulex europaeus agglutinin, UEA-1), N-acetylglucosaminyl and sialyl (Wheat germ agglutinin, WGA), N-glycolyl-neuraminic acid (Limax flavus agglutinin, LFA), and N-acetyl-D-galactosaminyl (Helix pomatia agglutinin, HPA). Several differences were revealed in the presence of sugar receptors on the surface of endothelial cells between the control and the hypertensive rats. Our studies showed also differences in the localization of the tested glycoconjugates between pial capillaries, small, medium-size and large pial arteries. The histochemical evaluation of alkaline phosphatase revealed an increased activity of the enzyme in the pial vessels of SHRs as compared with control rats with a similar localization of the enzyme activity. Some differences in the distribution of lectin binding sites and alkaline phosphatase activity could be associated with the different functions of particular segments of the pial vascular network.

  19. Coil combination for receive array spectroscopy: Are data-driven methods superior to methods using computed field maps?

    PubMed

    Rodgers, Christopher T; Robson, Matthew D

    2016-02-01

    Combining spectra from receive arrays, particularly X-nuclear spectra with low signal-to-noise ratios (SNRs), is challenging. We test whether data-driven combination methods are better than using computed coil sensitivities. Several combination algorithms are recast into the notation of Roemer's classic formula, showing that they differ primarily in their estimation of coil receive sensitivities. This viewpoint reveals two extensions of the whitened singular-value decomposition (WSVD) algorithm, using temporal or temporal + spatial apodization to improve the coil sensitivities, and thus the combined spectral SNR. Radiofrequency fields from an array were simulated and used to make synthetic spectra. These were combined with 10 algorithms. The combined spectra were then assessed in terms of their SNR. Validation used phantoms and cardiac (31) P spectra from five subjects at 3T. Combined spectral SNRs from simulations, phantoms, and humans showed the same trends. In phantoms, the combined SNR using computed coil sensitivities was lower than with WSVD combination whenever the WSVD SNR was >14 (or >11 with temporal apodization, or >9 with temporal + spatial apodization). These new apodized WSVD methods gave higher SNRs than other data-driven methods. In the human torso, at frequencies ≥49 MHz, data-driven combination is preferable to using computed coil sensitivities. Magn Reson, 2015. © 2015 The Authors. Magnetic Resonance in Medicine published by Wiley Periodicals, Inc. on behalf of International Society for Magnetic Resonance in Medicine. This is an open access article under the terms of the Creative Commons Attribution License, which permits use, distribution and reproduction in any medium, provided the original work is properly cited. Magn Reson Med 75:473-487, 2016. © 2015 The Authors. Magnetic Resonance in Medicine published by Wiley Periodicals, Inc. on behalf of International Society for Magnetic Resonance in Medicine. © 2015 The Authors. Magnetic

  20. Jonction Josephson en couche épaisse d'oxydes supraconducteurs

    NASA Astrophysics Data System (ADS)

    Gunther, C.; Monfort, Y.; Sing, M. Lam Chok; Bloyet, D.; Brousse, T.; Provost, J.; Raveau, B.

    1992-02-01

    Constrictions engraved in YBaCuO thick films fabricated by screen printing on YSZ substrate (J_c>3 000 A/cm^2 at 77 K) have been studied. Microwave irradiation of the devices at LN2 showed distinct Shapiro steps demonstrating the presence intrinsic Josephson junctions. The latter have an I_c(T) dependence fitting (1-T/T_c)^2 characteristic of SNS junctions. Furthermore, dc SQUID effects have also been observed with a peak-to-peak response simeq 0.2 μV and with a magnetic field periodicity extending through several hundred of φ_0. An energy resolution close to 3× 10^{-29} J/Hz is estimated for our constriction operating in the white noise frequency range (f>50 Hz) at 77 K. This sensitivity is adequate to use this flux sensor in many applications : geomagnetism, magnetocardiology, ... Nous avons étudié des constrictions gravées dans des couches épaisses d'YBaCuO déposées sur substrat de YSZ (J_c>3 000 A/cm^2 à 77 K). L'observation de marches de Shapiro lors d'irradiations des échantillons à 77 K par un champ HF met clairement en évidence la présence de jonctions Josephson intrinsèques de type SNS, leur dépendance en température du courant critique étant en (1-T/T_c)^2. De plus, nous avons obtenu des réponses en champ magnétique, caractéristiques des SQUIDs dc, d'amplitude 0,2 μVcc et dont la périodicité s'étend sur plusieurs centaines de φ_0. La résolution en énergie est de l'ordre de 3× 10^{-29} J/Hz en zone de bruit blanc (f>50 Hz) à 77 K. Cette sensibilité est suffisante pour envisager son utilisation dans des applications telles que : géomagnétisme, magnétocardiologie, ...

  1. Interactions between electrons, mesoscopic Josephson effect and asymmetric current fluctuations

    NASA Astrophysics Data System (ADS)

    Huard, B.

    2006-07-01

    This article discusses three experiments on the properties of electronic transport at the mesoscopic scale. The first one allowed to measure the energy exchange rate between electrons in a metal contaminated by a very weak concentration of magnetic impurities. The role played by magnetic impurities in the Kondo regime on those energy exchanges is quantitatively investigated, and the global measured exchange rate is larger than expected. The second experiment is a measurement of the current-phase relation in a system made of two superconductors linked through a single atom. We thus provide quantitative support for the recent description of the mesoscopic Josephson effect. The last experiment is a measurement of the asymmetry of the current fluctuations in a mesoscopic conductor, using a Josephson junction as a threshold detector. Cet ouvrage décrit trois expériences portant sur les propriétés du transport électronique à l'échelle mésoscopique. La première a permis de mesurer le taux d'échange d'énergie entre électrons dans un métal contenant une très faible concentration d'impuretés magnétiques. Nous avons validé la description quantitative du rôle des impuretés magnétiques dans le régime Kondo sur ces échanges énergétiques et aussi montré que le taux global d'échange est plus fort que prévu. La seconde expérience est une mesure de la relation courant-phase dans un système constitué de deux supraconducteurs couplés par un seul atome. Elle nous a permis de conforter quantitativement la récente description de l'effet Josephson mésoscopique. La dernière expérience est unemesure de l'asymétrie des fluctuations du courant dans un conducteur mésoscopique en utilisant une Jonction Josephson comme détecteur de seuil.

  2. Solitary juvenile xanthogranuloma of the temporal muscle and bone penetrating the dura mater in a 2-month-old boy.

    PubMed

    Cornips, Erwin M J; Cox, Kimberly E M; Creytens, David H K V; Granzen, Bernd; Weber, Jacobiene W; Ter Laak-Poort, Mariel P

    2009-12-01

    Juvenile xanthogranuloma (JXG) is a rare histiocytic disorder primarily observed during the first 2 years of life. Most patients present with a solitary cutaneous lesion; however, others present with extracutaneous manifestations or even with systemic involvement. The authors describe a 2-month-old boy in whom was diagnosed a unifocal extracutaneous JXG involving the temporal bone. Unlike 3 other cases of solitary JXGs of the temporal bone in the literature, the present case involved destruction of the dura mater and leptomeningeal enhancement surrounding the entire temporal lobe. The lesion did not regress after an initial biopsy procedure and had to be removed more radically because of progressive mass effect on the brain. The child recently underwent a reconstructive skull procedure and is doing well almost 2 years postoperatively without evidence of disease. This case demonstrates that even in instances of extensive disease a favorable outcome is possible without chemotherapy.

  3. Magneto-chiral anisotropy of the free electron on a helix

    NASA Astrophysics Data System (ADS)

    Krstić, V.; Rikken, G. L. J. A.

    2002-09-01

    The free electron on a helix as a simple model of a molecular chiral conductor is considered. In the presence of a static magnetic field parallel to the helix axis, it is found that both ballistic and diffusive electrical transport along the helix show a conductivity that depends linearly on the current and the magnetic field and on the handedness of the helix. These results agree qualitatively with the recently experimentally observed electrical magneto-chiral anisotropy in carbon nanotubes [V. Krstić, S. Roth, M. Burghard, K. Kern, G.L.J.A. Rikken, Max-Planck-Institut für Festkörperforschung, Stuttgart, Germany; Grenoble High Magnetic Field Laboratory, MPI-CNRS, Grenoble, France; Laboratoire National des Champs Magnétiques Pulsés, CNRS/INSA/UPS, UMS 5462, Toulouse, France].

  4. Physics for clinicians: Fluid-attenuated inversion recovery (FLAIR) and double inversion recovery (DIR) Imaging.

    PubMed

    Saranathan, Manojkumar; Worters, Pauline W; Rettmann, Dan W; Winegar, Blair; Becker, Jennifer

    2017-12-01

    A pedagogical review of fluid-attenuated inversion recovery (FLAIR) and double inversion recovery (DIR) imaging is conducted in this article. The basics of the two pulse sequences are first described, including the details of the inversion preparation and imaging sequences with accompanying mathematical formulae for choosing the inversion time in a variety of scenarios for use on clinical MRI scanners. Magnetization preparation (or T2prep), a strategy for improving image signal-to-noise ratio and contrast and reducing T 1 weighting at high field strengths, is also described. Lastly, image artifacts commonly associated with FLAIR and DIR are described with clinical examples, to help avoid misdiagnosis. 5 Technical Efficacy: Stage 2 J. Magn. Reson. Imaging 2017;46:1590-1600. © 2017 International Society for Magnetic Resonance in Medicine.

  5. Comparison of fMRI and PEPSI during language processing in children.

    PubMed

    Serafini, S; Steury, K; Richards, T; Corina, D; Abbott, R; Dager, S R; Berninger, V

    2001-02-01

    The present study explored the correlation between lactate as detected by MR spectroscopy (MRS) and blood oxygenation level dependent (BOLD) responses in male children during auditory-based language tasks. All subjects (N = 8) participated in one proton echo planar spectroscopic imaging (PEPSI) and one functional magnetic resonance imaging (fMRI) session that required phonological and lexical judgments to aurally presented stimuli. Valid PEPSI data was limited in the frontal areas of the brain due to the magnetic susceptibility of the eye orbits and frontal sinuses. Findings from the remainder of the brain indicate that subjects show a significant consistency across imaging techniques in the left temporal area during the lexical task, but not in any other measurable area or during the phonological task. Magn Reson Med 45:217-225, 2001. Copyright 2001 Wiley-Liss, Inc.

  6. A Common Miscitation of William Gilbert

    NASA Astrophysics Data System (ADS)

    van der Sluijs, Marinus Anthony

    2014-04-01

    Dozens of scientific textbooks [e.g., Spaldin, 2011, p. v; Krijgsman and Langereis, 2009, p. 252; Prölls, 2004, p. 211; Merrill et al., 1996, p. 7; Livingston, 1996, p. 27; Blakely, 1996, pp. xiv, 154; Gillmor, 1990, p. 9] attribute the famous dictum magnus magnes ipse est globus terrestris ("the terrestrial globe is itself a big magnet") to the English physician and scientist William Gilbert (1544-1603). It is repeatedly claimed that these words were contained in the title of Gilbert's book or one of his chapters [e.g., Carlowicz and Lopez, 2002, n.p.; Courtillot, 2002, pp. 26, 49; Lang and Whitney, 1991, p. 120]. Certainly, they convey the thrust of Gilbert's De Magnete, in which it was argued for the first time that the Earth sustains its own magnetic dipole field, on the basis of experimentation on magnets.

  7. Pure spin-Hall magnetoresistance in Rh/Y3Fe5O12 hybrid

    NASA Astrophysics Data System (ADS)

    Shang, T.; Zhan, Q. F.; Ma, L.; Yang, H. L.; Zuo, Z. H.; Xie, Y. L.; Li, H. H.; Liu, L. P.; Wang, B. M.; Wu, Y. H.; Zhang, S.; Li, Run-Wei

    2015-12-01

    We report an investigation of anisotropic magnetoresistance (AMR) and anomalous Hall resistance (AHR) of Rh and Pt thin films sputtered on epitaxial Y3Fe5O12 (YIG) ferromagnetic insulator films. For the Pt/YIG hybrid, large spin-Hall magne toresistance (SMR) along with a sizable conventional anisotropic magnetoresistance (CAMR) and a nontrivial temperature dependence of AHR were observed in the temperature range of 5-300 K. In contrast, a reduced SMR with negligible CAMR and AHR was found in Rh/YIG hybrid. Since CAMR and AHR are characteristics for all ferromagnetic metals, our results suggest that the Pt is likely magnetized by YIG due to the magnetic proximity effect (MPE) while Rh remains free of MPE. Thus the Rh/YIG hybrid could be an ideal model system to explore physics and devices associated with pure spin current.

  8. Diabetes induced renal urea transport alterations assessed with 3D hyperpolarized 13 C,15 N-Urea.

    PubMed

    Bertelsen, Lotte B; Nielsen, Per M; Qi, Haiyun; Nørlinger, Thomas S; Zhang, Xiaolu; Stødkilde-Jørgensen, Hans; Laustsen, Christoffer

    2017-04-01

    In the current study, we investigated hyperpolarized urea as a possible imaging biomarker of the renal function by means of the intrarenal osmolality gradient. Hyperpolarized three-dimensional balanced steady state 13 C MRI experiments alongside kidney function parameters and quantitative polymerase chain reaction measurements was performed on two groups of rats, a streptozotocin type 1 diabetic group and a healthy control group. A significant decline in intrarenal steepness of the urea gradient was found after 4 weeks of untreated insulinopenic diabetes in agreement with an increased urea transport transcription. MRI and hyperpolarized [ 13 C, 15 N]urea can monitor the changes in the corticomedullary urea concentration gradients in diabetic and healthy control rats. Magn Reson Med 77:1650-1655, 2017. © 2016 International Society for Magnetic Resonance in Medicine. © 2016 International Society for Magnetic Resonance in Medicine.

  9. Analysis of periprosthetic capsular tissue from women with silicone breast implants by magic-angle spinning NMR.

    PubMed

    Garrido, L; Young, V L

    1999-09-01

    The amount of silicone (polydimethylsiloxane [PDMS]) in capsular tissue surgically removed from women with breast implants was measured by using (29)Si and (1)H magic-angle spinning solid-state NMR spectroscopy. Twelve women having smooth surface silicone gel-filled implants, including a subject with "low-bleed" double-lumen implants, had detectable levels of PDMS ranging from 0. 05 to 9.8% silicon in wet tissue (w/w). No silicon-containing compounds other than PDMS were detected. No correlation was found between the amount of PDMS measured in the capsular tissue and the length of implantation time (Pearson correlation coefficient, r = 0. 22). The results showed no relationship between higher amounts of PDMS and capsular contracture (p = 0.74) or other symptoms (p = 0. 53). Magn Reson Med 42:436-441, 1999. Copyright 1999 Wiley-Liss, Inc.

  10. Doença cística da adventícia na veia basílica: relato de caso

    PubMed Central

    Vasconcelos, Rafael Sampaio; Cherubim, Cesar Augusto; França, Felipe Mavignier Pereira; D'allacqua, Eduardo de Lucca; Dalio, Marcelo Bellini; Joviliano, Edwaldo Edner

    2016-01-01

    Resumo A doença cística da adventícia é uma entidade rara que acomete principalmente a artéria poplítea. A ocorrência em veias é muito rara, e sua etiologia é desconhecida. Clinicamente, apresenta-se como isquemia, trombose ou dor a depender do território acometido. Apresentamos o caso de um paciente masculino jovem referindo nódulo no braço esquerdo. A angiorressonância magnética do membro mostrou lesão cística em contato com a veia basílica, com conteúdo homogêneo e sem realce pós-contraste. Foi realizada ressecção da lesão em bloco com o segmento venoso envolvido. O estudo anatomopatológico foi sugestivo de cisto de adventícia de veia basílica.

  11. Une localisation exceptionnelle de la tuberculose vertébrale Mal de Pott sous-occipital

    PubMed Central

    Yahyaoui, Sana; Majdoub, Senda; Zaghouani, Houneida; Fradj, Hosni Ben; Bakir, Dejla; Bouajina, Elyes; Kraiem, Chakib

    2013-01-01

    Le mal de Pott est la forme la plus commune de la tuberculose osseuse touchant essentiellement le rachis dorso-lombaire. La localisation sous-occipitale reste exceptionnelle. Le diagnostic de cette entité est le plus souvent tardif ce qui expose à des complications graves. Les radiographies standard ne sont parlantes qu’à un stade tardif de la maladie, d'où l'intérêt de l'imagerie moderne notamment la tomodensitométrie (TDM) et l'imagerie par résonance magnétique (IRM) qui permettent un diagnostic précoce. Nous rapportons un nouveau cas de tuberculose sous-occipitale. Le diagnostic était posé sur l'imagerie en coupe et confirmé histologiquement à la biopsie transorale. Sont rappelés les aspects en imagerie de cette localisation particulière du mal de Pott. PMID:23819005

  12. Uncover the mantle: rediscovering Gregório Lopes palette and technique with a study on the painting "Mater Misericordiae"

    NASA Astrophysics Data System (ADS)

    Antunes, Vanessa; Candeias, António; Oliveira, Maria J.; Carvalho, Maria L.; Dias, Cristina Barrocas; Manhita, Ana; Francisco, Maria J.; Costa, Sónia; Lauw, Alexandra; Manso, Marta

    2016-11-01

    Gregório Lopes (c. 1490-1550) was one of the most prominent painters of the renaissance and Mannerism in Portugal. The painting "Mater Misericordiae" made for the Sesimbra Holy House of Mercy, circa 1535-1538, is one of the most significant works of the artist, and his only painting on this theme, being also one of the most significant Portuguese paintings of sixteenth century. The recent restoration provided the possibility to study materially the painting for the first time, with a multianalytical methodology incorporating portable energy-dispersive X-ray fluorescence spectroscopy, scanning electron microscopy-energy-dispersive spectroscopy, micro-X-ray diffraction, micro-Raman spectroscopy and high-performance liquid chromatography coupled to diode array and mass spectrometry detectors. The analytical study was complemented by infrared reflectography, allowing the study of the underdrawing technique and also by dendrochronology to confirm the date of the wooden panels (1535-1538). The results of this study were compared with previous ones on the painter's workshop, and significant differences and similitudes were found in the materials and techniques used.

  13. Archaeometric analysis of Roman bronze coins from the Magna Mater temple using solid-state voltammetry and electrochemical impedance spectroscopy.

    PubMed

    Di Turo, Francesca; Montoya, Noemí; Piquero-Cilla, Joan; De Vito, Caterina; Coletti, Fulvio; Favero, Gabriele; Doménech-Carbó, Antonio

    2017-02-22

    Voltammetry of microparticles (VMP) and electrochemical impedance spectroscopy (EIS) techniques, complemented by SEM-EDX and Raman spectroscopy, were applied to a set of 15 Roman bronze coins and one Tessera from the temple of Magna Mater (Rome, Italy). The archaeological site, dated back between the second half and the end of the 4th century A.D., presented a complicated stratigraphic context. Characteristic voltammetric patterns for cuprite and tenorite for sub-microsamples of the corrosion layers of the coins deposited onto graphite electrodes in contact with 0.10 M HClO 4 aqueous solution yielded a grouping of the coins into three main groups. This grouping was confirmed and refined using EIS experiments of the coins immersed in air-saturated mineral water using the reduction of dissolved oxygen as a redox probe. The electrochemical grouping of coins corroborated the complex stratigraphy of the archaeological site and, above all, the reuse of the coins during the later periods due to the economic issues related to the fall of the Roman Empire. Copyright © 2016 Elsevier B.V. All rights reserved.

  14. Macroscopic Innervation of the Dura Mater Covering the Middle Cranial Fossa in Humans Correlated to Neurovascular Headache

    PubMed Central

    Lee, Shin-Hyo; Hwang, Seung-Jun; Koh, Ki-Seok; Song, Wu-Chul; Han, Sang-Don

    2017-01-01

    The trigeminovascular system within the cranial dura mater is a possible cause of headaches. The aim of this study is to investigate macroscopically dural innervation around the middle meningeal artery (MMA) in the middle cranial fossa. Forty-four sides of the cranial dura overlying the skull base obtained from 24 human cadavers were stained using Sihler’s method. Overall, the nervus spinosus (NS) from either the maxillary or mandibular trigeminal divisions ran along the lateral wall of the middle meningeal vein rather than that of the MMA. Distinct bundles of the NS running along the course of the frontal branches of the MMA were present in 81.8% of cases (N = 36). Others did not form dominant nerve bundles, instead giving off free nerve endings along the course of the MMA or dural connective tissue. The distribution of these nerve endings was similar to that of the course of the frontal, parietal and petrosal branches of the MMA (11.4%). The others were not restricted to a perivascular plexus, crossing the dural connective tissues far from the MMA (6.8%). These findings indicate that the NS generally travels alongside the course of the frontal branches of the MMA and terminates in the vicinity of the pterion. PMID:29311855

  15. Macroscopic Innervation of the Dura Mater Covering the Middle Cranial Fossa in Humans Correlated to Neurovascular Headache.

    PubMed

    Lee, Shin-Hyo; Hwang, Seung-Jun; Koh, Ki-Seok; Song, Wu-Chul; Han, Sang-Don

    2017-01-01

    The trigeminovascular system within the cranial dura mater is a possible cause of headaches. The aim of this study is to investigate macroscopically dural innervation around the middle meningeal artery (MMA) in the middle cranial fossa. Forty-four sides of the cranial dura overlying the skull base obtained from 24 human cadavers were stained using Sihler's method. Overall, the nervus spinosus (NS) from either the maxillary or mandibular trigeminal divisions ran along the lateral wall of the middle meningeal vein rather than that of the MMA. Distinct bundles of the NS running along the course of the frontal branches of the MMA were present in 81.8% of cases ( N = 36). Others did not form dominant nerve bundles, instead giving off free nerve endings along the course of the MMA or dural connective tissue. The distribution of these nerve endings was similar to that of the course of the frontal, parietal and petrosal branches of the MMA (11.4%). The others were not restricted to a perivascular plexus, crossing the dural connective tissues far from the MMA (6.8%). These findings indicate that the NS generally travels alongside the course of the frontal branches of the MMA and terminates in the vicinity of the pterion.

  16. Resultados do desenvolvimento de um propulsor à plasma no Brasil

    NASA Astrophysics Data System (ADS)

    Ferreira, I. S.; Ferreira, J. L.

    2003-08-01

    Uma das partes mais importantes de um satélite é o controle de atitude do mesmo. E se tratando de um satélite científico, a atenção para este sistema deve ser redobrada. Uma possibilidade atraente para executar esta tarefa é a propulsão elétrica. Aqui, mostraremos resultados obtidos pelo propulsor à plasma PHALL-01, desenvolvido na Universidade de Brasília entre 2000 e 2003. Este é derivado do propulsor russo SPT-100 (Stationary Plasma Thruster), mas com o emprego inovador de um arranjo de imãs permanentes como fonte do campo magnético, este último o agente da aceleração do plasma. Esta alteração foi motivada pelo objetivo de que o mesmo operasse com o mínimo de potência elétrica. A partir da formulação teórica do mecanismo de aceleração, tendo como base as equações da magnetohidrodinâmica, pode-se obter vínculos sob os quais o propulsor pudesse ser construído. O mais forte destes é o que dita a topologia do campo magnético. Sendo assim, foram realizadas simulações computacionais, que definiram a geometria do propulsor. Após construído, este foi diagnosticado usando-se sondas de Langmuir e analisadores de energia. Como resultados, obtivemos a distribuição espacial da temperatura, densidade e potencial do plasma, bem como a distribuição angular do feixe produzido pelo mesmo em vários regimes de operação. O espectro de energia do feixe de plasma também foi medido, indicando íons de até 560eV. Combinando estes resultados, calculou-se o empuxo do propulsor: 84mN; e o impulso específico: 1083s. Estes demonstram que o mesmo estará qualificado, num futuro próximo, para o emprego no controle de atitude de satélites científicos, ou até mesmo como parte do conjunto propulsor primário, responsáveis pela transferência de órbitas.

  17. On the measurement of 15N-{1H} nuclear Overhauser effects. 2. Effects of the saturation scheme and water signal suppression

    PubMed Central

    Ferrage, Fabien; Reichel, Amy; Battacharya, Shibani; Cowburn, David; Ghose, Ranajeet

    2013-01-01

    Measurement of steady-state 15N-{1H} nuclear Overhauser effects forms a cornerstone of most methods to determine protein backbone dynamics from spin-relaxation data, since it is the most reliable probe of very fast motions on the ps-ns timescale. We have, in two previous publications (J. Magn. Reson. 192 (2008), 302-313; J. Am. Chem. Soc. 131 (2009), 6048-6049) reevaluated spin-dynamics during steady-state (or “saturated”) and reference experiments, both of which are required to determine the NOE ratio. Here we assess the performance of several windowed and windowless sequences to achieve effective saturation of protons in steady-state experiments. We also evaluate the influence of the residual water signal due to radiation damping on the NOE ratio. We suggest a recipe that allows one to determine steady-state 15N-{1H} NOE's without artifacts and with the highest possible accuracy. PMID:20951618

  18. Electromagnetic response of a conductor with complex conductivity

    NASA Astrophysics Data System (ADS)

    Leylekian, L.; Ocio, M.; Hammann, J.

    1993-02-01

    The aim of this paper is to describe the electromagnetic response of a conductor with complex conductivity. We will show how the geometry of the measuring apparatus can modify the amplitude of this response. We will particularly emphasize the role that plays a complex conductivity, as we can find in granular superconductors, on the mesured magnetic susceptibility of the sample. Cet article a pour but de décrire la réponse électromagnétique d'un conducteur muni d'une conductivité complexe. Nous montrerons comment la géométrie du dispositif de mesure peut modifier l'amplitude de cette réponse. Nous insisterons particulièrement sur le rôle que joue une conductivité complexe, comme nous pouvons en trouver dans les supraconducteurs granulaires, sur la susceptibilité magnétique mesurée de l'échantillon.

  19. Levers for Thermoelectric Properties in Titania-Based Ceramics

    NASA Astrophysics Data System (ADS)

    Backhaus-Ricoult, Monika; Rustad, James R.; Vargheese, Deenamma; Dutta, Indrajit; Work, Kim

    2012-06-01

    While the beneficial impact of nanostructural engineering on thermoelectric performance has been demonstrated for many semiconducting materials (SiGe, skutterudites, PbTe2, etc.), no significant advantages have been reported for oxide nanomaterials. In this study, titania is used as a model material to compare the impact of grain size, doping and substitution, second-phase nanodispersion, and crystallographic defects on the electronic and thermal properties. It is shown that the lattice thermal conductivity can be most efficiently reduced by high densities of crystallographic planar defects in the Magnéli phases, while modification of grain size or introduction of second phases on length scales of 20 nm to 100 nm introduces only minor improvement. For the electronic properties, donor dopants such as niobium provide improvement of the power factor, but are not able to compete with the enhanced carrier concentration that is reached through oxygen vacancy introduction.

  20. Many-Body Effect in Spin Dephasing in n-Type GaAs Quantum Wells

    NASA Astrophysics Data System (ADS)

    Weng, Ming-Qi; Wu, Ming-Wei

    2005-03-01

    By constructing and numerically solving the kinetic Bloch equations we perform a many-body study of the spin dephasing due to the D'yakonov-Perel' effect in n-type GaAs (100) quantum wells for high temperatures. In our study, we include the spin-conserving scattering such as the electron-phonon, the electron-nonmagnetic impurity as well as the electron-electron Coulomb scattering into consideration. The dephasing obtained from our theory contains both the single-particle and the many-body contributions with the latter originating from the inhomogeneous broadening introduced by the DP term [J. Supercond.: Incorp. Novel Magn. 14 (2001) 245 Eur. Phys. J. B 18 (2000) 373]. Our result agrees very well with the experimental data [Phys. Rev. B 62 (2000) 13034] of Malinowski et al. We further show that in the case we study, the spin dephasing is dominated by the many-body effect.

  1. Intrauterine growth and intelligence within sibling pairs: findings from the Mater-University study of pregnancy and its outcomes.

    PubMed

    Lawlor, Debbie A; Bor, William; O'Callaghan, Michael J; Williams, Gail M; Najman, Jake M

    2005-04-01

    To examine the association between intrauterine growth and intelligence. Population based birth cohort study of sibling pairs born within a maximum of three years of each other. Mater-University women and children's hospital, Brisbane, Australia. 235 (470 children) sibling pairs. Among one randomly selected sibling from each pair verbal comprehension at age 5, general intelligence at age 14, and reading ability at age 14 increased linearly with increasing gestational age and sex standardised birth weight z scores. With adjustment for maternal age, race, and smoking during pregnancy, birth order, family income, and parental education the associations with verbal comprehension at age 5 and general intelligence at age 14 remained, whereas the association with reading ability at age 14 was attenuated to the null. Within sibling pairs, differences in intrauterine growth were positively associated with differences in verbal comprehension at age 5 (test score difference per one unit difference in birth weight z score = 1.52 (0.11 to 3.26)) and general intelligence at age 14 (1.09 (0.01 to 2.18)), but not with reading ability at age 14. Socioeconomic position or other fixed maternal characteristics do not seem to explain the positive association between intrauterine growth and childhood intelligence.

  2. Modified three-dimensional skull base model with artificial dura mater, cranial nerves, and venous sinuses for training in skull base surgery: technical note.

    PubMed

    Mori, Kentaro; Yamamoto, Takuji; Oyama, Kazutaka; Ueno, Hideaki; Nakao, Yasuaki; Honma, Keiichirou

    2008-12-01

    Experience with dissection of the cavernous sinus and the temporal bone is essential for training in skull base surgery, but the opportunities for cadaver dissection are very limited. A modification of a commercially available prototype three-dimensional (3D) skull base model, made by a selective laser sintering method and incorporating surface details and inner bony structures such as the inner ear structures and air cells, is proposed to include artificial dura mater, cranial nerves, venous sinuses, and the internal carotid artery for such surgical training. The transpetrosal approach and epidural cavernous sinus surgery (Dolenc's technique) were performed on this modified model using a high speed drill or ultrasonic bone curette under an operating microscope. The model could be dissected in almost the same way as a real cadaver. The modified 3D skull base model provides a good educational tool for training in skull base surgery.

  3. Corrigendum to "Fast computation of dynamic EPR spectra of biradicals" [J. Magn. Reson. Series A 103 (1993) 163-170

    NASA Astrophysics Data System (ADS)

    Sankarapandi, S.; Chandramouli, G. V. R.; Daul, C.; Manoharan, P. T.

    2018-01-01

    The authors regret for an error in units of rate constants K12 and K21 given in Tables 1, 3 and 4. The rate constants K12 and K21 are in gauss, and not in s-1 as mentioned in the article. The authors would like to apologise for any inconvenience caused.

  4. The developmental origin of adolescent alcohol use: findings from the Mater University Study of Pregnancy and its outcomes.

    PubMed

    Alati, Rosa; Clavarino, Alexandra; Najman, Jake M; O'Callaghan, Michael; Bor, William; Mamun, Abdullah Al; Williams, Gail M

    2008-11-01

    It is unclear whether fetal alcohol exposure contributes to alcohol use in adolescence. In this study, we examine the association between maternal alcohol use in pregnancy and adolescents' drinking patterns at age 14. The association of maternal alcohol exposure with early drinking was examined in 4363 adolescents taking part to the Mater University Study of Pregnancy (MUSP) and its outcomes, a population based birth cohort study commenced in Brisbane (Australia) in 1981. Mothers and children were followed up at birth, 5 and 14 years after the initial interview. Maternal alcohol use was assessed before and during pregnancy and at the 5 years follow-up. Adolescents' alcohol use was assessed at child age 14. In multivariable analysis those born of mothers who consumed 3+ glasses during pregnancy were at increased risk to report drinking 3+ glasses compared with those whose mothers reported no drinking or drinking up to 2 glasses. Comparisons controlling for drinking before pregnancy and at age 5 found the averaged odds ratio of maternal drinking in pregnancy on risk of reporting alcohol consumption of 3 and more glasses at age 14 was 2.74 (CI 1.70, 4.22). Our study suggests that they maybe a biological origin of early drinking. Further studies are needed to better disentangle the nature of the association and the role of other possible confounding factors.

  5. 3D printing from MRI Data: Harnessing strengths and minimizing weaknesses.

    PubMed

    Ripley, Beth; Levin, Dmitry; Kelil, Tatiana; Hermsen, Joshua L; Kim, Sooah; Maki, Jeffrey H; Wilson, Gregory J

    2017-03-01

    3D printing facilitates the creation of accurate physical models of patient-specific anatomy from medical imaging datasets. While the majority of models to date are created from computed tomography (CT) data, there is increasing interest in creating models from other datasets, such as ultrasound and magnetic resonance imaging (MRI). MRI, in particular, holds great potential for 3D printing, given its excellent tissue characterization and lack of ionizing radiation. There are, however, challenges to 3D printing from MRI data as well. Here we review the basics of 3D printing, explore the current strengths and weaknesses of printing from MRI data as they pertain to model accuracy, and discuss considerations in the design of MRI sequences for 3D printing. Finally, we explore the future of 3D printing and MRI, including creative applications and new materials. 5 J. Magn. Reson. Imaging 2017;45:635-645. © 2016 International Society for Magnetic Resonance in Medicine.

  6. Optimized distortion correction technique for echo planar imaging.

    PubMed

    Chen , N K; Wyrwicz, A M

    2001-03-01

    A new phase-shifted EPI pulse sequence is described that encodes EPI phase errors due to all off-resonance factors, including B(o) field inhomogeneity, eddy current effects, and gradient waveform imperfections. Combined with the previously proposed multichannel modulation postprocessing algorithm (Chen and Wyrwicz, MRM 1999;41:1206-1213), the encoded phase error information can be used to effectively remove geometric distortions in subsequent EPI scans. The proposed EPI distortion correction technique has been shown to be effective in removing distortions due to gradient waveform imperfections and phase gradient-induced eddy current effects. In addition, this new method retains advantages of the earlier method, such as simultaneous correction of different off-resonance factors without use of a complicated phase unwrapping procedure. The effectiveness of this technique is illustrated with EPI studies on phantoms and animal subjects. Implementation to different versions of EPI sequences is also described. Magn Reson Med 45:525-528, 2001. Copyright 2001 Wiley-Liss, Inc.

  7. Absolute Quantitation of Water and Metabolites in the Human Brain. II. Metabolite Concentrations

    NASA Astrophysics Data System (ADS)

    Kreis, R.; Ernst, T.; Ross, B. D.

    A method for determining absolute metabolite concentrations with in vivo1H magnetic resonance spectroscopy is presented. Using the compartmentation model introduced in the preceding paper of this series ( J. Magn. Reson. B102, 1, 1993), it is possible to express NMR results in terms of most commonly used concentration units. The proposed scheme, involving the measurement of an external standard as well as of the localized water signal, is verified on cerebral spectra obtained from 22 subjects. Besides concentrations, longitudinal and transverse relaxation times are determined for parietal white and occipital gray matter. The determination of these quantities crucially depends on the analysis of the T2 signal decay as a function of echo time. The in vivo concentrations of the four metabolites N-acetyl aspartate, creatine plus phosphocreatine, choline, and myo-inositol are in good agreement with biochemical determinations performed in vitro. Two clinical examples emphasize the relevance of absolute quantitation in the investigation of human neuropathology and normal development.

  8. MRI measurement of the temporal evolution of relative CMRO(2) during rat forepaw stimulation.

    PubMed

    Mandeville, J B; Marota, J J; Ayata, C; Moskowitz, M A; Weisskoff, R M; Rosen, B R

    1999-11-01

    This study reports the first measurement of the relative cerebral metabolic rate of oxygen utilization (rCMRO(2)) during functional brain activation with sufficient temporal resolution to address the dynamics of blood oxygen level-dependent (BOLD) MRI signal. During rat forepaw stimulation, rCMRO(2) was determined in somatosensory cortex at 3-sec intervals, using a model of BOLD signal and measurements of the change in BOLD transverse relaxation rate, the resting state BOLD transverse relaxation rate, relative cerebral blood flow (rCBF), and relative cerebral blood volume (rCBV). Average percentage changes from 10 to 30 sec after onset of forepaw stimulation for rCBF, rCBV, rCMRO(2), and BOLD relaxation rate were 62 +/- 16, 17 +/- 2, 19 +/- 17, and -26 +/- 12, respectively. A poststimulus undershoot in BOLD signal was quantitatively attributed to the temporal mismatch between changes in blood flow and volume, and not to the role of oxygen metabolism. Magn Reson Med 42:944-951, 1999. Copyright 1999 Wiley-Liss, Inc.

  9. Unwanted signal leakage in excitation sculpting with single axis gradients.

    PubMed

    Jerschow, A

    1999-03-01

    Excitation sculpting (T-L. Hwang and A. J. Shaka, J. Magn. Reson. A 112, 275-279 (1995)) used for solvent suppression and selective excitation in NMR bases its success on the ability to remove baseline and phase errors created by the application of selective rf pulses. This is achieved by the application of two pulsed field gradient (PFG) echoes in sequence. It is essential that the two pairs of PFGs select the coherence transfer steps independently of each other, which is conveniently achieved if they are applied along orthogonal spatial axes. Here, the much more common case where both PFG pairs must be applied along a single axis is investigated. This is shown to lead to complications for certain ratios of PFG strengths. The original theory of excitation sculpting is restated in the spherical basis for convenience. Some of the effects can only be explained by invoking the dipolar demagnetizing field. Copyright 1999 Academic Press.

  10. Actividad funcional cerebral en estado de reposo: REDES EN CONEXIÓN

    PubMed Central

    Proal, Erika; Alvarez-Segura, Mar; de la Iglesia-Vayá, Maria; Martí-Bonmatí, Luis; Castellanos, F. Xavier

    2015-01-01

    Resumen El análisis de la conectividad funcional mediante resonancia magnética funcional (RMf) puede llevarse a cabo durante la realización de una tarea, la percepción de un estímulo o en estado de reposo. Estos análisis han demostrado su fiabilidad y reproducibilidad con diferentes enfoques (matemáticos, estadísticos, físicos) para seleccionar los vóxeles activados. El estudio de la señal de baja frecuencia en la actividad cerebral a través del contraste BOLD en estado de reposo ha revelado patrones de actividad cortical sincronizados, permitiendo describir la arquitectura funcional intrínseca del cerebro humano. La comunidad científica internacional dispone de recursos compartidos que contribuirán mediante este análisis de RMf en estado de reposo a la obtención de diagnósticos y tratamientos más precisos y avanzados en el campo de las neurociencias. PMID:21365601

  11. Nuclear quadrupole resonance lineshape analysis for different motional models: Stochastic Liouville approach

    NASA Astrophysics Data System (ADS)

    Kruk, D.; Earle, K. A.; Mielczarek, A.; Kubica, A.; Milewska, A.; Moscicki, J.

    2011-12-01

    A general theory of lineshapes in nuclear quadrupole resonance (NQR), based on the stochastic Liouville equation, is presented. The description is valid for arbitrary motional conditions (particularly beyond the valid range of perturbation approaches) and interaction strengths. It can be applied to the computation of NQR spectra for any spin quantum number and for any applied magnetic field. The treatment presented here is an adaptation of the "Swedish slow motion theory," [T. Nilsson and J. Kowalewski, J. Magn. Reson. 146, 345 (2000), 10.1006/jmre.2000.2125] originally formulated for paramagnetic systems, to NQR spectral analysis. The description is formulated for simple (Brownian) diffusion, free diffusion, and jump diffusion models. The two latter models account for molecular cooperativity effects in dense systems (such as liquids of high viscosity or molecular glasses). The sensitivity of NQR slow motion spectra to the mechanism of the motional processes modulating the nuclear quadrupole interaction is discussed.

  12. Plant-expressed cocaine hydrolase variants of butyrylcholinesterase exhibit altered allosteric effects of cholinesterase activity and increased inhibitor sensitivity.

    PubMed

    Larrimore, Katherine E; Kazan, I Can; Kannan, Latha; Kendle, R Player; Jamal, Tameem; Barcus, Matthew; Bolia, Ashini; Brimijoin, Stephen; Zhan, Chang-Guo; Ozkan, S Banu; Mor, Tsafrir S

    2017-09-05

    Butyrylcholinesterase (BChE) is an enzyme with broad substrate and ligand specificities and may function as a generalized bioscavenger by binding and/or hydrolyzing various xenobiotic agents and toxicants, many of which target the central and peripheral nervous systems. Variants of BChE were rationally designed to increase the enzyme's ability to hydrolyze the psychoactive enantiomer of cocaine. These variants were cloned, and then expressed using the magnICON transient expression system in plants and their enzymatic properties were investigated. In particular, we explored the effects that these site-directed mutations have over the enzyme kinetics with various substrates of BChE. We further compared the affinity of various anticholinesterases including organophosphorous nerve agents and pesticides toward these BChE variants relative to the wild type enzyme. In addition to serving as a therapy for cocaine addiction-related diseases, enhanced bioscavenging against other harmful agents could add to the practicality and versatility of the plant-derived recombinant enzyme as a multivalent therapeutic.

  13. Theory of long-lived nuclear spin states in methyl groups and quantum-rotor induced polarisation.

    PubMed

    Dumez, Jean-Nicolas; Håkansson, Pär; Mamone, Salvatore; Meier, Benno; Stevanato, Gabriele; Hill-Cousins, Joseph T; Roy, Soumya Singha; Brown, Richard C D; Pileio, Giuseppe; Levitt, Malcolm H

    2015-01-28

    Long-lived nuclear spin states have a relaxation time much longer than the longitudinal relaxation time T1. Long-lived states extend significantly the time scales that may be probed with magnetic resonance, with possible applications to transport and binding studies, and to hyperpolarised imaging. Rapidly rotating methyl groups in solution may support a long-lived state, consisting of a population imbalance between states of different spin exchange symmetries. Here, we expand the formalism for describing the behaviour of long-lived nuclear spin states in methyl groups, with special attention to the hyperpolarisation effects observed in (13)CH3 groups upon rapidly converting a material with low-barrier methyl rotation from the cryogenic solid state to a room-temperature solution [M. Icker and S. Berger, J. Magn. Reson. 219, 1 (2012)]. We analyse the relaxation properties of methyl long-lived states using semi-classical relaxation theory. Numerical simulations are supplemented with a spherical-tensor analysis, which captures the essential properties of methyl long-lived states.

  14. Automated processing for proton spectroscopic imaging using water reference deconvolution.

    PubMed

    Maudsley, A A; Wu, Z; Meyerhoff, D J; Weiner, M W

    1994-06-01

    Automated formation of MR spectroscopic images (MRSI) is necessary before routine application of these methods is possible for in vivo studies; however, this task is complicated by the presence of spatially dependent instrumental distortions and the complex nature of the MR spectrum. A data processing method is presented for completely automated formation of in vivo proton spectroscopic images, and applied for analysis of human brain metabolites. This procedure uses the water reference deconvolution method (G. A. Morris, J. Magn. Reson. 80, 547(1988)) to correct for line shape distortions caused by instrumental and sample characteristics, followed by parametric spectral analysis. Results for automated image formation were found to compare favorably with operator dependent spectral integration methods. While the water reference deconvolution processing was found to provide good correction of spatially dependent resonance frequency shifts, it was found to be susceptible to errors for correction of line shape distortions. These occur due to differences between the water reference and the metabolite distributions.

  15. Speeding up dynamic spiral chemical shift imaging with incoherent sampling and low-rank matrix completion.

    PubMed

    DeVience, Stephen J; Mayer, Dirk

    2017-03-01

    To improve the temporal and spatial resolution of dynamic 13 C spiral chemical shift imaging via incoherent sampling and low-rank matrix completion (LRMC). Spiral CSI data were both simulated and acquired in rats, and undersampling was implemented retrospectively and prospectively by pseudorandomly omitting a fraction of the spiral interleaves. Undersampled data were reconstructed with both LRMC and a conventional inverse nonuniform fast Fourier transform (iNUFFT) and compared with fully sampled data. Two-fold undersampling with LRMC reconstruction enabled a two-fold improvement in temporal or spatial resolution without significant artifacts or spatiotemporal distortion. Conversely, undersampling with iNUFFT reconstruction created strong artifacts that obscured the image. LRMC performed better at time points with strong metabolite signal. Incoherent undersampling and LRMC provides a way to increase the spatiotemporal resolution of spiral CSI without degrading data integrity. Magn Reson Med 77:951-960, 2017. © 2016 International Society for Magnetic Resonance in Medicine. © 2016 International Society for Magnetic Resonance in Medicine.

  16. The extended Fourier transform for 2D spectral estimation.

    PubMed

    Armstrong, G S; Mandelshtam, V A

    2001-11-01

    We present a linear algebraic method, named the eXtended Fourier Transform (XFT), for spectral estimation from truncated time signals. The method is a hybrid of the discrete Fourier transform (DFT) and the regularized resolvent transform (RRT) (J. Chen et al., J. Magn. Reson. 147, 129-137 (2000)). Namely, it estimates the remainder of a finite DFT by RRT. The RRT estimation corresponds to solution of an ill-conditioned problem, which requires regularization. The regularization depends on a parameter, q, that essentially controls the resolution. By varying q from 0 to infinity one can "tune" the spectrum between a high-resolution spectral estimate and the finite DFT. The optimal value of q is chosen according to how well the data fits the form of a sum of complex sinusoids and, in particular, the signal-to-noise ratio. Both 1D and 2D XFT are presented with applications to experimental NMR signals. Copyright 2001 Academic Press.

  17. H2BC: a new technique for NMR analysis of complex carbohydrates.

    PubMed

    Petersen, Bent O; Vinogradov, Evguenii; Kay, William; Würtz, Peter; Nyberg, Nils T; Duus, Jens Ø; Sørensen, Ole W

    2006-03-20

    It is demonstrated that the H2BC NMR pulse sequence (J. Am. Chem. Soc.2005, 127, 6154, Magn. Reson. Chem.2005, 43, 971-974) offers unambiguous assignments and significant simplification of NMR spectra of large and complex carbohydrates compared to other techniques for the establishment of correlations over more than one bond. H2BC almost exclusively correlates protons and proton-bearing carbon spins separated by two covalent bonds and is independent of occasionally vanishing (2)J(CH) coupling constants, which alleviates the problem of missing two-bond correlations in HMBC spectra. H2BC also solves the problem of distinguishing two- and three-bond correlations in HSQC-TOCSY or HMBC. It is a further asset of H2BC that the experiment is significantly shorter than HMBC and HSQC-TOCSY, and hence less sensitive to transverse relaxation. The H2BC experiment is demonstrated on an approximately 30-residue oligosaccharide from Francisella victoria.

  18. Vibrational and reorientationl relaxation in liquid tert-butyl bromide and tert-butyl bromide- d9

    NASA Astrophysics Data System (ADS)

    Szostak, R.; Hawranek, J. P.

    1992-12-01

    The vibrational and reorientational correlation functions of the ν s(CBr) mode in liquid tert-butyl bromide (TBBr) and in its deuterated analogue (TBBr- d9) were determined from Raman bandshapes. The Kubo product δτ m obtained by fitting the Rothschild equation to experimental data amounts to 0.36-0.45 for the studied bands, which indicates a fairly fast modulation regime in these systems. The approximation of experimental rotational correlation functions with the help of the J-diffusion model yields values of 0.11-0.12ps for the angular momentum correlation time. The second-order rotational correlation times (1.7-2.0ps) agree well with the NMR results of D.W. Aksnes, K. Ramstad and O.P. Björlykke, Magn. Reson. Chem., 25 (1987) 1063. Selected bandshape parameters for δ(CCC) in both compounds, ϱ(CH 3) in TBBr and ν s(CC) in TBBR- d9 were also quoted.

  19. Détermination assistée par ordinateur de la structure des molécules organiques

    NASA Astrophysics Data System (ADS)

    Nuzillard, J.-M.

    1998-02-01

    Nuclear Magnetic Resonance spectroscopy offers the unique possibility of accessing proximity relationships between atoms by means of chemical shift correlation experiments. Structure determination of small molecules has become thus much simpler. Computer programs can use directly correlation information for structure analysis. The use and operation mechanism of such a program, LSD (Logic for Structure Determination) are presented. The example compound is gibberellic acid, a natural product. La spectroscopie de Résonance Magnétique Nucléaire offre un moyen unique de déterminer des relations de proximité entre atomes par le biais des expériences de corrélation. L'analyse structurale de petites molécules organiques s'en trouve extrêmement facilitée. Des programmes informatiques peuvent utiliser directement les informations de corrélation pour déduire des structures. Le fonctionnement et l'usage d'un tel programme, LSD (Logic for Structure Determination), sont détaillés sur un exemple, l'acide gibberellique.

  20. Review of dynamic contrast-enhanced MRI: Technical aspects and applications in the musculoskeletal system.

    PubMed

    Sujlana, Parvinder; Skrok, Jan; Fayad, Laura M

    2018-04-01

    Although postcontrast imaging has been used for many years in musculoskeletal imaging, dynamic contrast enhanced (DCE) MRI is not routinely used in many centers around the world. Unlike conventional contrast-enhanced sequences, DCE-MRI allows the evaluation of the temporal pattern of enhancement in the musculoskeletal system, perhaps best known for its use in oncologic applications (such as differentiating benign from malignant tumors, evaluating for treatment response after neoadjuvant chemotherapy, and differentiating postsurgical changes from residual tumor). However, DCE-MRI can also be used to evaluate inflammatory processes such as Charcot foot and synovitis, and evaluate bone perfusion in entities like Legg Calve Perthes disease and arthritis. Finally, vascular abnormalities and associated complications may be better characterized with DCE-MRI than conventional imaging. The goal of this article is to review the applications and technical aspects of DCE-MRI in the musculoskeletal system. 5 Technical Efficacy: Stage 3 J. Magn. Reson. Imaging 2018;47:875-890. © 2017 International Society for Magnetic Resonance in Medicine.

  1. Diet-Induced Obesity Enhances TRPV1-Mediated Neurovascular Reactions in the Dura Mater.

    PubMed

    Marics, Balázs; Peitl, Barna; Pázmándi, Kitti; Bácsi, Attila; Németh, József; Oszlács, Orsolya; Jancsó, Gábor; Dux, Mária

    2017-03-01

    Exploring the pathophysiological changes in transient receptor potential vanilloid 1 (TRPV1) receptor of the trigeminovascular system in high-fat, high-sucrose (HFHS) diet-induced obesity of experimental animals. Clinical and experimental observations suggest a link between obesity and migraine. Accumulating evidence indicates that metabolic and immunological alterations associated with obesity may potentially modulate trigeminovascular functions. A possible target for obesity-induced pathophysiological changes is the TRPV1/capsaicin receptor which is implicated in the pathomechanism of headaches in a complex way. Male Sprague-Dawley rats were fed a regular (n = 25) or HFHS diet (n = 26) for 20 weeks. At the end of the dietary period, body weight of the animals was normally distributed in both groups and it was significantly higher in animals on HFHS diet. Therefore, experimental groups were regarded as control and HFHS diet-induced obese groups. Capsaicin-induced changes in meningeal blood flow and release of calcitonin gene-related peptide (CGRP) from dural trigeminal afferents were measured in control and obese rats. The distribution of TRPV1- and CGRP-immunoreactive meningeal sensory nerves was also compared in whole mount preparations of the dura mater. Metabolic parameters of the animals were assessed by examining glucose and insulin homeostasis as well as plasma cytokine concentrations. HFHS diet was accompanied by reduced food consumption and greater fluid and energy intakes in addition to increased body weight of the animals. HFHS diet increased fasting blood glucose and insulin concentrations as well as levels of circulating proinflammatory cytokines interleukin-1β and interleukin-6. In obese animals, dural application of the archetypal TRPV1 agonist capsaicin resulted in significantly augmented vasodilatory and vasoconstrictor responses as compared to controls. Diet-induced obesity was also associated with enhanced basal and capsaicin

  2. Effet d'un champ magnétique uniforme sur les instabilités de Rayleigh-Bénard avec effet Soret

    NASA Astrophysics Data System (ADS)

    Ben Sassi, Mokhtar; Kaddeche, Slim; Abdennadher, Ali; Henry, Daniel; Hadid, Hamda Ben; Mojtabi, Abdelkader

    2016-01-01

    The effect of both magnitude and orientation of a uniform magnetic field on the critical transition occurring within an electrically conducting binary fluid layer, stratified in temperature and concentration, taking into account the Soret effect, is investigated numerically. For such a configuration, the results show that the critical thresholds corresponding to an arbitrary orientated magnetic field can be derived from those obtained for a vertical magnetic field and that the axes of the marginal cells are aligned with the horizontal component of the magnetic field. Moreover, an analytical study is conducted to investigate the impact of the magnetic field on long-wavelength instabilities. The effect of the magnetic field on such instabilities reveals a new phenomenon consisting in major changes of the unstable modes that lose their unicellular nature to regain their multi-roll characteristic, as it is the case without magnetic field for ψ <ψℓ0 = 131 Le / (34 - 131 Le). For a binary fluid characterized by a Lewis number Le and a separation factor ψ >ψℓ0, the value of the Hartmann number Haℓ (ψ , Le) corresponding to that transition responsible for a significant change in mass and heat transfer can be determined from the analytical relations derived in this work.

  3. Analyse des possibilités de fonctionnement en régime des désexcitation des moteurs à aimants permanents

    NASA Astrophysics Data System (ADS)

    Multon, Bernard; Lucidarme, Jean; Prévond, Laurent

    1995-05-01

    In this paper, we study the extending of speed range of motors (or generators) with permanent magnet inductor and supplied by electronic converter. The amplitude of phase voltage and current waveforms are limited by electronics supply. The aim of this study is to achieve a maximum power near of the base speed one on an extended speed range. This require an airgap flux weakening so called “flux weakening” above base speed. A parametric analysis of motor electromagnetic characteristics is made to show the influence of armature reaction and magnetic saliency on speed range. We show that exists an ideal condition to obtain a constant power speed range theoretically unlimited. Magnetic saliency permits to enhance the power factor especially when L_d> L_q. As main hypotheses, we consider no saturation, e.m.f. and current sine waveforms and a sinusoidal airgap flux density. Finally, we recapitulate the permanent magnet rotor structures able to obtain a flux-weakening operation. Cet article traite de l'extension de la plage de vitesse des moteurs (ou alternateurs) à excitation par aimants permanents et alimentés par convertisseur électronique. La tension et le courant sont limités en amplitude par l'alimentation électronique.L'objectif est d'obtenir une puissance proche de celle correspondant au régime de base sur une plage de vitesse étendue. Ceci nécessite une réduction de flux d'entrefer ou “désexition” au delà de la vitesse de base. Une analyse paramétrique des caractéristiques du moteur est effectuée pour mettre en évidence l'influence de la réaction d'induit et de la saillance magnétique. Nous montrons qu'il existe une condition idéale pour obtenir une plage de fonctionnement à puissance constante théoriquement illimitée. La saillance magnétique permet d'accroître le facteur de puissance surtout lorsque L_d> L_q. Les principales hypothèses de cette étude sont l'absence de saturation, des f.e.m. et des courants sinusoïdaux et une

  4. Eléments traces dans le sérum des enfants malnutris et bien nourris vivants à Lubumbashi et Kawama dans un contexte d'un environnement de pollution minière

    PubMed Central

    Musimwa, Aimée Mudekereza; Kanteng, Gray Wakamb; Kitoko, Hermann Tamubango; Luboya, Oscar Numbi

    2016-01-01

    Introduction La place des éléments traces métalliques essentiels en nutrition humaine ne peut plus être ignorée. Les déficits d'apports, les carences secondaires souvent sous – estimées, et les carences iatrogènes font le lit de pathologies telles que les infections et autres. D'où leurs dosages ont une importance particulière pour en évaluer la gravité et faciliter une prise en charge précoce ou améliorer le régime alimentaire. Cette étude a eu pour objectif de déterminer le profil sanguin en éléments traces (cuivre, sélénium, zinc, fer, chrome, cobalt, etc) chez les enfants malnutris et biens nourris dans un milieu minier à Lubumbashi. Méthodes Trois cents onze cas ont été colligés, 182 malnutris et 129 biens nourris, dans une étude descriptive transversale, effectuée de juillet 2013 à décembre 2014. Pour lequel un échantillonnage exhaustif a été réalisé. Le dosage des métaux dans le sérum s'est fait à l’ ICP-OES (spectrométrie de masse à plasma gon induit) au laboratoire de l'Office Congolais de Contrôle de Lubumbashi. Résultats Les oligoéléments essentiels (cuivre, zinc, sélénium et fer) se retrouvent à des concentrations très basses chez les enfants malnutris comme chez les biens nourris. L'arsenic, le cadmium, le magnésium et le manganèse se présentent à des concentrations normales par rapport aux valeurs de références chez les enfants biens nourris. L'antimoine, le chrome, le plomb et le cobalt se retrouvent élevés chez les malnutris et biens nourris. Le nickel est normal chez les malnutris et les biens nourris. Le magnésium, manganèse se sont présentés à des taux très bas chez les enfants malnutris. Conclusion Les enfants malnutris et biens nourris présentent une malnutrition aux oligo-éléments essentiels associés aux éléments traces métalliques. Ce qui permet de supposer qu'une carence en micronutriments essentiel favorise l'absorption des métaux lourds. PMID:27583075

  5. NMR imaging and cryoporometry of swelling clays

    NASA Astrophysics Data System (ADS)

    Dvinskikh, Sergey V.; Szutkowski, Kosma; Petrov, Oleg V.; Furó, István.

    2010-05-01

    strength as well as investigating the effect of the confining geometry and material surface properties seem to be worth to pursue. Acknowledgements: This work has been supported by the Swedish Nuclear Fuel and Waste Management Co (SKB) and the Swedish Research Council VR. References: [1] Dvinskikh S. V., Szutkowski K., Furó I. MRI profiles over a very wide concentration ranges: application to swelling of a bentonite clay. J. Magn. Reson. 198, 146 (2009). [2] Petrov O. V., Furó I. NMR cryoporometry: Principles, applications and potential. Prog. Nucl. Magn. Reson. Spec. 54, 97 (2009).

  6. Study of magnetic domain evolution in an auxetic plane of Galfenol using Kerr microscopy

    NASA Astrophysics Data System (ADS)

    Raghunath, Ganesh; Flatau, Alison B.

    2015-05-01

    Galfenol (FexGa100-x), a magnetostrictive alloy (3/2λ 110-400 ppm) of Iron and Gallium exhibits an in-plane auxetic response in the ⟨110⟩ crystallographic direction. Negative Poisson's ratios have been observed in response to application of stress fields, where values of as low as -0.7 have been reported for compositions of greater than roughly 20% Ga [Zhang et al., J. Appl. Phys. 108(2), 023513 (2010)] and in response to application of magnetic fields, where values of as low as -2.5 have been reported to be expected for compositions of less than roughly 20% Ga [G. Raghunath and A. B. Flatau, IEEE Trans. Magn. (in press)]. Several models have been proposed to understand these two distinct phenomena. Galfenol samples with less than 20% Ga also exhibit an unusual response to an increasing magnetic field applied along the ⟨110⟩ direction. The longitudinal strain which increases initially with applied field experiences a dip (until ˜10 mT) before increasing again to reach saturation. The transverse strain increases and reaches a maximum value (at the same field of ˜10 mT) and then drops from the maximum by 5%-10% as magnetic saturation is approached [G. Raghunath and A. B. Flatau, IEEE Trans. Magn. (in press)].This work deals with discussing the evolution of magnetic domains in a 16 at. % Ga single crystal Galfenol sample when subjected to magnetic fields in the ⟨110⟩ direction in the (100) plane. The magnetic domains on the surface of mechanically polished Galfenol samples were imaged using Magneto-Optic Kerr Effect microscopy. Simultaneously, the strains along the longitudinal and transverse ⟨110⟩ directions were recorded using a bi-directional strain gauge rosette mounted on the unpolished bottom surface of the planar samples. The energy from the applied magnetic field is expected to grow the ⟨110⟩ oriented domains at the expense of domains oriented along all other directions. But since the plane has an easy ⟨100⟩ axis, we expect the

  7. Magnetic levitation and MHD propulsion

    NASA Astrophysics Data System (ADS)

    Tixador, P.

    1994-04-01

    Magnetic levitation and MHD propulsion are now attracting attention in several countries. Different superconducting MagLev and MHD systems will be described concentrating on, above all, the electromagnetic aspect. Some programmes occurring throughout the world will be described. Magnetic levitated trains could be the new high speed transportation system for the 21st century. Intensive studies involving MagLev trains using superconductivity have been carried out in Japan since 1970. The construction of a 43 km long track is to be the next step. In 1991 a six year programme was launched in the United States to evaluate the performances of MagLev systems for transportation. The MHD (MagnetoHydroDynamic) offers some interesting advantages (efficiency, stealth characteristics, ...) for naval propulsion and increasing attention is being paid towards it nowadays. Japan is also up at the top with the tests of Yamato I, a 260 ton MHD propulsed ship. Depuis quelques années nous assistons à un redémarrage de programmes concernant la lévitation et la propulsion supraconductrices. Différents systèmes supraconducteurs de lévitation et de propulsion seront décrits en examinant plus particulièrement l'aspect électromagnétique. Quelques programmes à travers le monde seront abordés. Les trains à sustentation magnétique pourraient constituer un nouveau mode de transport terrestre à vitesse élevée (500 km/h) pour le 21^e siècle. Les japonais n'ont cessé de s'intéresser à ce système avec bobine supraconductrice. Ils envisagent un stade préindustriel avec la construction d'une ligne de 43 km. En 1991 un programme américain pour une durée de six ans a été lancé pour évaluer les performances des systèmes à lévitation pour le transport aux Etats Unis. La MHD (Magnéto- Hydro-Dynamique) présente des avantages intéressants pour la propulsion navale et un regain d'intérêt apparaît à l'heure actuelle. Le japon se situe là encore à la pointe des d

  8. Dura Mater Stimulates Human Adipose-Derived Stromal Cells to Undergo Bone Formation in Mouse Calvarial Defects

    PubMed Central

    Levi, Benjamin; Nelson, Emily R.; Li, Shuli; James, Aaron W.; Hyun, Jeong S.; Montoro, Daniel T.; Lee, Min; Glotzbach, Jason P.; Commons, George W.; Longaker, Michael T.

    2015-01-01

    Human adipose-derived stromal cells (hASCs) have a proven capacity to aid in osseous repair of calvarial defects. However, the bone defect microenvironment necessary for osseous healing is not fully understood. In this study, we postulated that the cell-cell interaction between engrafted ASCs and host dura mater (DM) cells is critical for the healing of calvarial defects. hASCs were engrafted into critical sized calvarial mouse defects. The DM-hASC interaction was manipulated surgically by DM removal or by insertion of a semipermeable or nonpermeable membrane between DM and hASCs. Radiographic, histologic, and gene expression analyses were performed. Next, the hASC-DM interaction is assessed by conditioned media (CM) and coculture assays. Finally, bone morphogenetic protein (BMP) signaling from DM was investigated in vivo using novel BMP-2 and anti-BMP-2/4 slow releasing scaffolds. With intact DM, osseous healing occurs both from host DM and engrafted hASCs. Interference with the DM-hASC interaction dramatically reduced calvarial healing with abrogated BMP-2–Smad-1/5 signaling. Using CM and coculture assays, mouse DM cells stimulated hASC osteogenesis via BMP signaling. Through in vivo manipulation of the BMP-2 pathway, we found that BMP-2 plays an important role in DM stimulation of hASC osteogenesis in the context of calvarial bone healing. BMP-2 supplementation to a defect with disrupted DM allowed for bone formation in a nonhealing defect. DM is an osteogenic cell type that both participates in and stimulates osseous healing in a hASC-engrafted calvarial defect. Furthermore, DM-derived BMP-2 paracrine stimulation appears to play a key role for hASC mediated repair. PMID:21656608

  9. The "RESEAU MATER": An efficient infection control for endometritis, but not for urinary tract infection after vaginal delivery.

    PubMed

    Ayzac, Louis; Caillat-Vallet, Emmanuelle; Girard, Raphaële; Berland, Michel

    "RESEAU MATER" is useful to monitor nosocomial infections in maternity and contributes to the decreasing trend of it, since its implementation. Specifically, this network demonstrates its efficiency in the control of endometritis following vaginal deliveries, but not in the control of urinary tract infections. The aim of this study is to determine whether the difference between the control of endometritis and of urinary tract infection could be explained by an unsuitable regression model or by an unsuitable care policy concerning urinary cares. This study includes (1) the analysis of historic data of the network and (2) the description of French guidelines for maternity cares and available evaluations, concerning endometritis and urinary tract infection prevention. Univariate and multivariate odds ratios (ORs) were calculated for the total study period of 1999-2013, for these infections and their risk factors. The endometritis frequency is decreasing, in association with no significant evolution of associated risk factors, but urinary tract infection frequency is constant, in association with a increasing trend of its risk factors such as intermittent catheterization and epidural analgesia. In French guidelines, all preventive measures against endometritis are clearly broadcasted by all field operators, and repeated audits have reinforced the control of their application. But preventive measures against urinary tract infection seem to be broadcasted exclusively in the circle of infection prevention agencies and not in the obstetrics societies or in the Health Ministry communication. Urinary tract infection prevention requires a clearer public and professional policy in favor of a more efficient urinary cares, with a specific target to maternity. Copyright © 2016 King Saud Bin Abdulaziz University for Health Sciences. Published by Elsevier Ltd. All rights reserved.

  10. Specific coil design for SENSE: a six-element cardiac array.

    PubMed

    Weiger, M; Pruessmann, K P; Leussler, C; Röschmann, P; Boesiger, P

    2001-03-01

    In sensitivity encoding (SENSE), the effects of inhomogeneous spatial sensitivity of surface coils are utilized for signal localization in addition to common Fourier encoding using magnetic field gradients. Unlike standard Fourier MRI, SENSE images exhibit an inhomogeneous noise distribution, which crucially depends on the geometrical sensitivity relations of the coils used. Thus, for optimum signal-to-noise-ratio (SNR) and noise homogeneity, specialized coil configurations are called for. In this article we study the implications of SENSE imaging for coil layout by means of simulations and imaging experiments in a phantom and in vivo. New, specific design principles are identified. For SENSE imaging, the elements of a coil array should be smaller than for common phased-array imaging. Furthermore, adjacent coil elements should not overlap. Based on the findings of initial investigations, a configuration of six coils was designed and built specifically for cardiac applications. The in vivo evaluation of this array showed a considerable SNR increase in SENSE images, as compared with a conventional array. Magn Reson Med 45:495-504, 2001. Copyright 2001 Wiley-Liss, Inc.

  11. Rapid Radiofrequency Field Mapping In Vivo Using Single-Shot STEAM MRI

    PubMed Central

    Helms, Gunther; Finsterbusch, Jürgen; Weiskopf, Nikolaus; Dechent, Peter

    2008-01-01

    Higher field strengths entail less homogeneous RF fields. This may influence quantitative MRI and MRS. A method for rapidly mapping the RF field in the human head with minimal distortion was developed on the basis of a single-shot stimulated echo acquisition mode (STEAM) sequence. The flip angle of the second RF pulse in the STEAM preparation was set to 60° and 100° instead of 90°, inducing a flip angle-dependent signal change. A quadratic approximation of this trigonometric signal dependence together with a calibration accounting for slice excitation-related bias allowed for directly determining the RF field from the two measurements only. RF maps down to the level of the medulla could be obtained in less than 1 min and registered to anatomical volumes by means of the T2-weighted STEAM images. Flip angles between 75% and 125% of the nominal value were measured in line with other methods. Magn Reson Med 60:739–743, 2008. © 2008 Wiley-Liss, Inc. PMID:18727090

  12. Short-term observations of double-peaked Na emission from Mercury's exosphere

    NASA Astrophysics Data System (ADS)

    Massetti, S.; Mangano, V.; Milillo, A.; Mura, A.; Orsini, S.; Plainaki, C.

    2017-04-01

    We report the analysis of short-term ground-based observations of the exospheric Na emission (D1 and D2 lines) from Mercury, which was characterized by two high-latitude peaks confined near the magnetospheric cusp footprints. During a series of scheduled observations from the Télescope Héliographique pour l'Etude du Magnétisme et des Instabilités Solaires (THEMIS) telescope, achieved by scanning the whole planet, we implemented a series of extra measurements by recording the Na emission from a narrow north-south strip only, centered above the two emission peaks. Our aim was to inspect the existence of short-term variations, which were never analyzed before from ground-based observations, and their possible correlation with interplanetary magnetic field variations. Though Mercury possesses a miniature magnetosphere, characterized by fast reconnection events that develop on a timescale of few minutes, ground-based observations show that the exospheric Na emission pattern can be globally stable for a prolonged period (some days) and also exhibits fluctuations in the time range of tens of minutes.

  13. Método numérico das diferenças finitas no domínio do tempo aplicado a ondas Alfvén em plasma astrofísico

    NASA Astrophysics Data System (ADS)

    Dos Santos, L. C.; Kintopp, J. A.; Jatenco-Pereira, V.; Opher, R.

    2003-08-01

    Ondas Alfvén em plasma astrofísico têm sido objeto de intenso estudo nas últimas décadas pelo fato de apresentarem papel importante em muitas áreas de pesquisa na astrofísica. Particularmente são importantes no mecanismo de aquecimento da coroa solar; em ventos estelares; em jatos galácticos e extragalácticos; em discos protoestelares, etc. A formulação para diferenças finitas no domínio do tempo (FDTD), aplicada a plasma magnetizado é desenvolvida para estudo das propriedades de ondas Alfvén em três dimensões (3D-FDTD). O método é aplicado inicialmente a um plasma homogêneo e isotérmico imerso em uma região com campo magnético externo B0, que sofre uma pequena perturbação. Uma vez gerada a onda, esta perturbação é retirada e, então analisamos a evolução temporal das ondas, bem como a forma de seu amortecimento.

  14. Levitation of water and organic substances in high static magnetic fields

    NASA Astrophysics Data System (ADS)

    Beaugnon, E.; Tournier, R.

    1991-08-01

    The levitation of various diamagnetic liquid and solid substances such as water, ethanol, acetone, bismuth, antimony, graphite, wood and plastic has been achieved at room temperature in a strong inhomogeneous static magnetic field. These experiments were performed in the hybrid magnet at the Service National des Champs Intenses (CNRS, Grenoble). These findings show that high field superconducting magnets could be used to provide a contactless, low gravity environment for the elaboration of a wide range of materials. En utilisant les forts champs magnétiques produits par la bobine hybride du Service National des Champs Intenses (CNRS, Grenoble), nous avons obtenu àtempérature ambiante la lévitation de substances diamagnétiques solides ou liquides telles que l'eau, l'alcool, l'acétone, le bismuth, l'antimoine, le graphite, le bois et le plastique. Ces résultats montrent que les bobines supraconductrices peuvent être utilisées pour l'élaboration de nombreux matériaux en gravité réduite, sans contact avec un contenant.

  15. Offline Impedance Measurements for Detection and Mitigation of Dangerous Implant Interactions: An RF Safety Prescreen

    PubMed Central

    Ellenor, Christopher W; Stang, Pascal P; Etezadi-Amoli, Maryam; Pauly, John M; Scott, Greig C

    2015-01-01

    Purpose The concept of a “radiofrequency safety prescreen” is investigated, wherein dangerous interactions between radiofrequency fields used in MRI, and conductive implants in patients are detected through impedance changes in the radiofrequency coil. Theory The behavior of coupled oscillators is reviewed, and the resulting, observable impedance changes are discussed. Methods A birdcage coil is loaded with a static head phantom and a wire phantom with a wire close to its resonant length, the shape, position, and orientation of which can be changed. Interactions are probed with a current sensor and network analyzer. Results Impedance spectra show dramatic, unmistakable splitting in cases of strong coupling, and strong correlation is observed between induced current and scattering parameters. Conclusions The feasibility of a new, low-power prescreening technique has been demonstrated in a simple phantom experiment, which can unambiguously detect resonant interactions between an implanted wire and an imaging coil. A new technique has also been presented which can detect parallel transmit null modes for the wire. Magn Reson Med 73:1328–1339, 2015. © 2014 Wiley Periodicals, Inc. PMID:24623586

  16. Cerebral (1)H MRS alterations in recreational 3, 4-methylenedioxymethamphetamine (MDMA, "ecstasy") users.

    PubMed

    Chang, L; Ernst, T; Grob, C S; Poland, R E

    1999-10-01

    3,4-methylenedioxymethamphetamine (MDMA) is an illicit drug that has been associated with serotonergic axonal degeneration in animals. This study evaluates neurochemical abnormalities in recreational MDMA users. Twenty-two MDMA users and 37 normal subjects were evaluated with magnetic resonance imaging (MRI) and proton magnetic resonance spectroscopy ((1)H MRS) in the mid-frontal, mid-occipital, and parietal brain regions. (1)H MRS showed normal N-acetyl (NA) compounds in all brain regions. The myo-inositol (MI) concentration (+16.3%, P = 0.04) and the MI to creatine (CR) ratio (+14.1%, P = 0. 01) were increased in the parietal white matter of MDMA users. The cumulative lifetime MDMA dose showed significant effects on [MI] in the parietal white matter and the occipital cortex. The normal NA concentration suggests a lack of significant neuronal injury in recreational MDMA users. However, the usage-related increase in MI suggests that exposure to MDMA, even at recreational doses, may cause increased glial content. J. Magn. Reson. Imaging 1999;10:521-526. Copyright 1999 Wiley-Liss, Inc.

  17. Electromagnetic modelling of conductive or superconductive microstrip lines using spice as electromagnetic solver

    NASA Astrophysics Data System (ADS)

    Dinh, Thanh Vu; Cabon, Béatrice; Daoud, Nahla; Chilo, Jean

    1992-11-01

    This paper presents a simple and efficient method for calculating the propagating line parameters (actually, a microstrip one) and its magnetic fields, by simulating an original equivalent circuit with an electrical nodal simulator (SPICE). The losses in the normal conducting line (due to DC losses and to skin effect losses) and also in the superconducting one can be investigated. This allows us to integrate the electromagnetic solutions to the CAD softwares. Dans ce papier, une méthode simple et efficace pour calculer les paramètres de propagation d'une ligne microruban et les champs magnétiques qu'elle engendre est présentée; pour cela, nous simulons un circuit original équivalent à l'aide du simulateur nodal SPICE. Les pertes dans une ligne conductrice (pertes continues et par effet de peau) ainsi que dans une ligne supraconductrice peuvent être considérées. Les solutions électromagnétiques peuvent être intégrées dans les simulateurs de CAO.

  18. Vastly accelerated linear least-squares fitting with numerical optimization for dual-input delay-compensated quantitative liver perfusion mapping.

    PubMed

    Jafari, Ramin; Chhabra, Shalini; Prince, Martin R; Wang, Yi; Spincemaille, Pascal

    2018-04-01

    To propose an efficient algorithm to perform dual input compartment modeling for generating perfusion maps in the liver. We implemented whole field-of-view linear least squares (LLS) to fit a delay-compensated dual-input single-compartment model to very high temporal resolution (four frames per second) contrast-enhanced 3D liver data, to calculate kinetic parameter maps. Using simulated data and experimental data in healthy subjects and patients, whole-field LLS was compared with the conventional voxel-wise nonlinear least-squares (NLLS) approach in terms of accuracy, performance, and computation time. Simulations showed good agreement between LLS and NLLS for a range of kinetic parameters. The whole-field LLS method allowed generating liver perfusion maps approximately 160-fold faster than voxel-wise NLLS, while obtaining similar perfusion parameters. Delay-compensated dual-input liver perfusion analysis using whole-field LLS allows generating perfusion maps with a considerable speedup compared with conventional voxel-wise NLLS fitting. Magn Reson Med 79:2415-2421, 2018. © 2017 International Society for Magnetic Resonance in Medicine. © 2017 International Society for Magnetic Resonance in Medicine.

  19. Detection of glucose in the human brain with 1 H MRS at 7 Tesla.

    PubMed

    Kaiser, Lana G; Hirokazu, Kawaguchi; Fukunaga, Masaki; B Matson, Gerald

    2016-12-01

    A new method is proposed for noninvasive detection of glucose in vivo using proton MR spectroscopy at 7 Tesla. The proposed method utilizes J-difference editing to uncover the resonance of beta-glucose (β-glc) at 3.23 ppm, which is strongly overlapped with choline. Calculations using the density matrix formalism are used to maximize the signal-to-noise ratio of the β-glc resonance at 3.23 ppm. The calculations are verified using phantom and in vivo data collected at 7 Tesla. The proposed method allows observation of the glucose signal at 3.23 ppm in the human brain spectrum. Additional co-edited resonances of N-acetylaspartylglutamatate and glutathione are also detected in the same experiment. The proposed method does not require carbon ( 13 C)- labeled glucose injections and 13 C hardware; as such, it has a potential to provide valuable information on intrinsic glucose concentration in the human brain in vivo. Magn Reson Med 76:1653-1660, 2016. © 2016 International Society for Magnetic Resonance in Medicine. © 2016 International Society for Magnetic Resonance in Medicine.

  20. Solid state nuclear magnetic resonance with magic-angle spinning and dynamic nuclear polarization below 25 K

    PubMed Central

    Thurber, Kent R.; Potapov, Alexey; Yau, Wai-Ming; Tycko, Robert

    2012-01-01

    We describe an apparatus for solid state nuclear magnetic resonance (NMR) with dynamic nuclear polarization (DNP) and magic-angle spinning (MAS) at 20–25 K and 9.4 Tesla. The MAS NMR probe uses helium to cool the sample space and nitrogen gas for MAS drive and bearings, as described earlier (Thurber et al., J. Magn. Reson. 2008) [1], but also includes a corrugated waveguide for transmission of microwaves from below the probe to the sample. With a 30 mW circularly polarized microwave source at 264 GHz, MAS at 6.8 kHz, and 21 K sample temperature, greater than 25-fold enhancements of cross-polarized 13C NMR signals are observed in spectra of frozen glycerol/water solutions containing the triradical dopant DOTOPA-TEMPO when microwaves are applied. As demonstrations, we present DNP-enhanced one-dimensional and two-dimensional 13C MAS NMR spectra of frozen solutions of uniformly 13C-labeled L-alanine and melittin, a 26-residue helical peptide that we have synthesized with four uniformly 13C-labeled amino acids. PMID:23238592

  1. Magnetospheric turbulence and substorm expansion phase onset

    NASA Astrophysics Data System (ADS)

    Antonova, Elizaveta; Stepanova, Marina; Kirpichev, Igor; Pulinets, Maria; Znatkova, Svetlana; Ovchinnikov, Ilya; Kornilov, Ilya; Kornilova, Tatyana

    Magnetosphere of the Earth is formed in the process of turbulent solar wind flow around the obstacle -magnetic field of the Earth. The level of turbulence in the magnetosheath and geo-magnetic tail is very high even during periods of comparatively stable solar wind parameters. Such situation requires checking of the most popular concepts of the nature of magnetospheric activity. Properties of magnetosheath and magnetospheric turbulence are analyzed in connec-tion with the problem of the nature of substorms and localization of substorm onset. The large-scale picture of the plasma velocity fluctuations obtained using data of INTERBALL and Geotail observations is analyzed. It is shown that it is possible to select surrounding the Earth at geocentric distances from 7Re till 10Re plasma ring with comparatively low level of fluctuations. Results of observations demonstrating isolated substorm onset inside this ring are summarized. It is shown that the non-contradictory picture of large-scale magnetospheric convection and substorm dynamics can be obtained taking into account high level of magne-tosheath and magnetospheric turbulence.

  2. Breast MRI radiogenomics: Current status and research implications.

    PubMed

    Grimm, Lars J

    2016-06-01

    Breast magnetic resonance imaging (MRI) radiogenomics is an emerging area of research that has the potential to directly influence clinical practice. Clinical MRI scanners today are capable of providing excellent temporal and spatial resolution, which allows extraction of numerous imaging features via human extraction approaches or complex computer vision algorithms. Meanwhile, advances in breast cancer genetics research has resulted in the identification of promising genes associated with cancer outcomes. In addition, validated genomic signatures have been developed that allow categorization of breast cancers into distinct molecular subtypes as well as predict the risk of cancer recurrence and response to therapy. Current radiogenomics research has been directed towards exploratory analysis of individual genes, understanding tumor biology, and developing imaging surrogates to genetic analysis with the long-term goal of developing a meaningful tool for clinical care. The background of breast MRI radiogenomics research, image feature extraction techniques, approaches to radiogenomics research, and promising areas of investigation are reviewed. J. Magn. Reson. Imaging 2016;43:1269-1278. © 2015 Wiley Periodicals, Inc.

  3. Phase unwrapping with graph cuts optimization and dual decomposition acceleration for 3D high-resolution MRI data.

    PubMed

    Dong, Jianwu; Chen, Feng; Zhou, Dong; Liu, Tian; Yu, Zhaofei; Wang, Yi

    2017-03-01

    Existence of low SNR regions and rapid-phase variations pose challenges to spatial phase unwrapping algorithms. Global optimization-based phase unwrapping methods are widely used, but are significantly slower than greedy methods. In this paper, dual decomposition acceleration is introduced to speed up a three-dimensional graph cut-based phase unwrapping algorithm. The phase unwrapping problem is formulated as a global discrete energy minimization problem, whereas the technique of dual decomposition is used to increase the computational efficiency by splitting the full problem into overlapping subproblems and enforcing the congruence of overlapping variables. Using three dimensional (3D) multiecho gradient echo images from an agarose phantom and five brain hemorrhage patients, we compared this proposed method with an unaccelerated graph cut-based method. Experimental results show up to 18-fold acceleration in computation time. Dual decomposition significantly improves the computational efficiency of 3D graph cut-based phase unwrapping algorithms. Magn Reson Med 77:1353-1358, 2017. © 2016 International Society for Magnetic Resonance in Medicine. © 2016 International Society for Magnetic Resonance in Medicine.

  4. Blue nano titania made in diffusion flames.

    PubMed

    Teleki, Alexandra; Pratsinis, Sotiris E

    2009-05-21

    Blue titanium suboxide nanoparticles (including Magneli phases) were formed directly without any post-processing or addition of dopants by combustion of titanium-tetra-isopropoxide (TTIP) vapor at atmospheric pressure. Particle size, phase composition, rutile and anatase crystal sizes as well as the blue coloration were controlled by rapid quenching of the flame with a critical flow nozzle placed at various heights above the burner. The particles showed a broad absorption in the near-infrared region and retained their blue color upon storage in ambient atmosphere. A high concentration of paramagnetic Ti3+ centres was found in the substoichiometric particles by electron paramagnetic resonance (EPR) spectroscopy. Furthermore particles with controlled band gap energy from 3.2 to 3.6 eV were made by controlling the burner-nozzle-distance from 10 to 1 cm, respectively. The color robustness and extent of suboxidation could be further enhanced by co-oxidation of TTIP with hexamethyldisiloxane in the flame resulting in SiO2-coated titanium suboxide particles. The process is cost-effective and green while the particles produced can replace traditional blue colored, cobalt-containing pigments.

  5. Restoring literary wholeness to the fragmented account of Antoine Despine's magnetic cure of Estelle L'Hardy's dissociative disorder.

    PubMed

    McKeown, Joanne M

    2007-10-01

    Dr. Charles-Humbert Antoine Despine's (1777-1852) De L'Emploi du magnétisme animal et des eaux minerales dans le traitement des maladies nerveuses, suivi d'une observation très curieuse de guérison de névropathie [A Study of the uses of animal magnetism in the treatment of disorders of the nervous system followed by a case of a highly unusual cure of neuropathy] (Paris: Germer, Baillière, 1840) is one of the earliest published, complete accounts of a successful cure with animal magnetism of a dissociative disorder. Despine's methodical and gentle treatment of more than 20 patients with multiple personalities repeatedly brought fusion to separation. His writing style displays a lack of order and unity that resembles the dissociative symptoms of his patients, but the monograph's sloppiness belies Despine's methodical approach to his work and his thoughtful handling of his patients. This paper explores these inconsistencies and how translators of the monograph act as literary therapists for his confused and fragmented account.

  6. Approach of automatic 3D geological mapping: the case of the Kovdor phoscorite-carbonatite complex, NW Russia.

    PubMed

    Kalashnikov, A O; Ivanyuk, G Yu; Mikhailova, J A; Sokharev, V A

    2017-07-31

    We have developed an approach for automatic 3D geological mapping based on conversion of chemical composition of rocks to mineral composition by logical computation. It allows to calculate mineral composition based on bulk rock chemistry, interpolate the mineral composition in the same way as chemical composition, and, finally, build a 3D geological model. The approach was developed for the Kovdor phoscorite-carbonatite complex containing the Kovdor baddeleyite-apatite-magnetite deposit. We used 4 bulk rock chemistry analyses - Fe magn , P 2 O 5 , CO 2 and SiO 2 . We used four techniques for prediction of rock types - calculation of normative mineral compositions (norms), multiple regression, artificial neural network and developed by logical evaluation. The two latter became the best. As a result, we distinguished 14 types of phoscorites (forsterite-apatite-magnetite-carbonate rock), carbonatite and host rocks. The results show good convergence with our petrographical studies of the deposit, and recent manually built maps. The proposed approach can be used as a tool of a deposit genesis reconstruction and preliminary geometallurgical modelling.

  7. Quantitative determination of conformational, dynamic, and kinetic parameters of a ligand-protein/DNA complex from a complete relaxation and conformational exchange matrix analysis of intermolecular transferred NOESY.

    PubMed

    Moseley, H N; Lee, W; Arrowsmith, C H; Krishna, N R

    1997-05-06

    We report a quantitative analysis of the 13C-edited intermolecular transferred NOESY (inter-TrNOESY) spectrum of the trp-repressor/operator complex (trp-rep/op) with [ul-13C/15N]-L-tryptophan corepressor using a computer program implementing complete relaxation and conformational exchange matrix (CORCEMA) methodology [Moseley et al. (1995) J. Magn. Reson. 108B, 243-261]. Using complete mixing time curves of three inter-TrNOESY peaks between the tryptophan and the Trp-rep/op, this self-consistent analysis determined the correlation time of the bound species (tauB = 13.5 ns) and the exchange off-rate (k(off) = 3.6 s(-1)) of the corepressor. In addition, the analysis estimated the correlation time of the free species (tauF approximately 0.15 ns). Also, we demonstrate the sensitivity of these inter-TrNOESY peaks to several factors including the k(off) and orientation of the tryptophan corepressor within the binding site. The analysis indicates that the crystal structure orientation for the corepressor is compatible with the solution NMR data.

  8. Microarray analysis of gene expression after electrical stimulation of the dura mater surrounding the superior sagittal sinus in conscious adult rats.

    PubMed

    Jiang, Lei; Dong, Zhao; Li, Fengpeng; Liu, Ruozhuo; Qiu, Enchao; Wang, Xiaolin; Yu, Shengyuan

    2014-01-01

    The molecular and cellular origins of migraine headache are among the most complex problems in contemporary neurology. Up to now the pathogenesis of migraine still remains unclearly defined. The objective of this study was to explore new factors that may be related to the mechanism of migraine. The present study performed a comprehensive analysis of gene expression in the trigeminal nucleus caudalis induced by electrical stimulation of dura mater surrounding the superior sagittal sinus in conscious rats using microarray analysis followed by quantitative real-time reverse-transcribed polymerase chain reaction (qRT-PCR) verification. Student's two sample t-test was employed when two groups were compared. A P value <0.05 was considered to be statistically significant. Comparing the placebo and the electrical stimulation groups, 40 genes were determined to be significantly differentially expressed. These significantly differentially expressed genes were involved in many pathways, including transporter activity, tryptophan metabolism, G protein signaling, kinase activity, actin binding, signal transducer activity, anion transport, protein folding, enzyme inhibitor activity, coenzyme metabolism, binding, ion transport, cell adhesion, metal ion transport, oxidoreductase activity, mitochondrion function, and others. Most of the genes were involved in more than 2 pathways. Of particular interest is the up-regulation of Phactr3 and Akap5 and the down-regulation of Kdr. These findings may provide important clues for a better understanding of the molecular mechanism of migraine.

  9. Ondas de choque em jatos de quasares e objetos BL Lacertae

    NASA Astrophysics Data System (ADS)

    Melo, F. E.; Botti, L. C. L.

    2003-08-01

    Este trabalho é parte de um projeto que vem sendo realizado há dois anos no CRAAM, cujos objetivos principais são analisar e aplicar um modelo generalizado de ondas de choque em jatos relativísticos de plasma, presentes em quasares e objetos BL Lacertae, para explicar a variabilidade observada nestes objetos. O método consiste em uma decomposição de curvas de luz em séries de explosões similares, em várias freqüências, baseando-se em uma evolução espectro-temporal média das explosões. A partir da evolução média, um ajuste de cada explosão é feito com base em equações empíricas, modificando-se apenas parâmetros específicos de cada explosão. Inicialmente o modelo foi aplicado ajustando-se as curvas de luz a explosões delineadas por uma evolução do choque em três estágios, segundo a predominância do processo de emissão: síncrotron, Compton e adiabático. Entretanto, nesta nova fase de projeto, visando uma parametrização mais concisa, uma otimização do algoritmo de ajuste e uma convergência mais rápida, a formulação para cada evento foi assumida com uma evolução em apenas dois estágios: subida e descida. Isto possibilitou uma ótima delineação das curvas de luz das fontes OV236, OJ287, 3C273 e BL Lac, entre 1980 e 2000, nas freqüências 4.8, 8.0, 14.5 e 22 GHz, utilizando-se dados do Observatório da Universidade de Michigan, do Observatório do Itapetinga (Atibaia SP) e do Observatório Metsähovi. Como conclusões importantes, verificou-se que: os parâmetros ajustados descrevem o comportamento do jato; os valores do índice que descreve a expansão do jato sugerem que o mesmo se expande de uma forma não-cônica; o campo magnético é turbulento atrás da frente de choque; e as peculiaridades das explosões são devidas à influência de grandezas tais como o coeficiente da distribuição espectral de energia dos elétrons, a intensidade de campo magnético e o fator de feixe Doppler, no início do choque.

  10. A novel bioreactor for the generation of highly aligned 3D skeletal muscle-like constructs through orientation of fibrin via application of static strain.

    PubMed

    Heher, Philipp; Maleiner, Babette; Prüller, Johanna; Teuschl, Andreas Herbert; Kollmitzer, Josef; Monforte, Xavier; Wolbank, Susanne; Redl, Heinz; Rünzler, Dominik; Fuchs, Christiane

    2015-09-01

    The generation of functional biomimetic skeletal muscle constructs is still one of the fundamental challenges in skeletal muscle tissue engineering. With the notion that structure strongly dictates functional capabilities, a myriad of cell types, scaffold materials and stimulation strategies have been combined. To further optimize muscle engineered constructs, we have developed a novel bioreactor system (MagneTissue) for rapid engineering of skeletal muscle-like constructs with the aim to resemble native muscle in terms of structure, gene expression profile and maturity. Myoblasts embedded in fibrin, a natural hydrogel that serves as extracellular matrix, are subjected to mechanical stimulation via magnetic force transmission. We identify static mechanical strain as a trigger for cellular alignment concomitant with the orientation of the scaffold into highly organized fibrin fibrils. This ultimately yields myotubes with a more mature phenotype in terms of sarcomeric patterning, diameter and length. On the molecular level, a faster progression of the myogenic gene expression program is evident as myogenic determination markers MyoD and Myogenin as well as the Ca(2+) dependent contractile structural marker TnnT1 are significantly upregulated when strain is applied. The major advantage of the MagneTissue bioreactor system is that the generated tension is not exclusively relying on the strain generated by the cells themselves in response to scaffold anchoring but its ability to subject the constructs to individually adjustable strain protocols. In future work, this will allow applying mechanical stimulation with different strain regimes in the maturation process of tissue engineered constructs and elucidating the role of mechanotransduction in myogenesis. Mechanical stimulation of tissue engineered skeletal muscle constructs is a promising approach to increase tissue functionality. We have developed a novel bioreactor-based 3D culture system, giving the user the

  11. Modélisation de la dynamique de la chaîne peptidique des protéines en solution par RMN à travers les couplages dipolaires

    NASA Astrophysics Data System (ADS)

    Bouvignies, G.; Bernadó, P.; Blackledge, M.

    2005-11-01

    L'activité d'une protéine est liée non seulement à sa structure, mais également à sa dynamique, et il est important de connaître la nature de ses mouvements pour comprendre sa fonction biologique. La résonance magnétique nucléaire est particulièrement utile pour étudier la dynamique d'une molécule en solution sur une gamme de temps de corrélation très large. En particulière, la relaxation des spins 15N ou 13C donne accès aux mouvements moléculaires avec les temps caractéristiques entre les dizaines de picosecondes et le temps de corrélation rotationelle de la molécule (autour de 10ns pour une protéine monomérique de 20 kD à 300 K). Les vitesses de relaxation dépendent de la flexibilité de chaque site, et peuvent être caractérisé en termes d'amplitude et de temps caractéristique locale. La précision de ces paramètres et sa compréhension en termes de fonction exigent que la réorientation globale de la molécule soit correctement prise en compte. Ces méthodes expérimentales, qui seront présentées ici brièvement, font maintenant partie de la panoplie d'expériences appliquées dans l'étude de la relation structure-dynamique d'une protéine et ses partenaires. Néanmoins les mouvements plus lents, entre la nano et la milliseconde, sont plus difficiles à étudier, et il y a très peu d'information disponible sur la nature de la dynamique de la chaîne peptidique dans cette gamme de temps par RMN. Très récemment de nouvelles méthodologies ont été proposées, basées sur l'alignement préférentiel d'une protéine par rapport au champ magnétique, induit par dissolution de la molécule dans un cristal liquide très dilué. Dans ces conditions les changements conformationels sur des temps caractéristique plus lents (jusqu'au millisecondes) peuvent être étudiés. Nous présenterons cette technique, et quelques résultats, comparant la dynamique rapide (ps-ns), et plus lente le long de la chaîne peptidique de quatre protéines.

  12. A spiral-based volumetric acquisition for MR temperature imaging.

    PubMed

    Fielden, Samuel W; Feng, Xue; Zhao, Li; Miller, G Wilson; Geeslin, Matthew; Dallapiazza, Robert F; Elias, W Jeffrey; Wintermark, Max; Butts Pauly, Kim; Meyer, Craig H

    2018-06-01

    To develop a rapid pulse sequence for volumetric MR thermometry. Simulations were carried out to assess temperature deviation, focal spot distortion/blurring, and focal spot shift across a range of readout durations and maximum temperatures for Cartesian, spiral-out, and retraced spiral-in/out (RIO) trajectories. The RIO trajectory was applied for stack-of-spirals 3D imaging on a real-time imaging platform and preliminary evaluation was carried out compared to a standard 2D sequence in vivo using a swine brain model, comparing maximum and mean temperatures measured between the two methods, as well as the temporal standard deviation measured by the two methods. In simulations, low-bandwidth Cartesian trajectories showed substantial shift of the focal spot, whereas both spiral trajectories showed no shift while maintaining focal spot geometry. In vivo, the 3D sequence achieved real-time 4D monitoring of thermometry, with an update time of 2.9-3.3 s. Spiral imaging, and RIO imaging in particular, is an effective way to speed up volumetric MR thermometry. Magn Reson Med 79:3122-3127, 2018. © 2017 International Society for Magnetic Resonance in Medicine. © 2017 International Society for Magnetic Resonance in Medicine.

  13. 7T: Physics, safety, and potential clinical applications.

    PubMed

    Kraff, Oliver; Quick, Harald H

    2017-12-01

    With more than 60 installed magnetic resonance imaging (MRI) systems worldwide operating at a magnetic field strength of 7T or higher, ultrahigh-field (UHF) MRI has been established as a platform for clinically oriented research in recent years. Profound technical and methodological developments have helped overcome the inherent physical challenges of UHF radiofrequency (RF) signal homogenization in the human body. The ongoing development of dedicated RF coil arrays was pivotal in realizing UHF body MRI, beyond mere brain imaging applications. Another precondition to clinical application of 7T MRI is the safety testing of implants and the establishment of safety concepts. Against this backdrop, 7T MRI and MR spectroscopy (MRS) recently have demonstrated capabilities and potentials for clinical diagnostics in a variety of studies. This article provides an overview of the immanent physical challenges of 7T UHF MRI and discusses recent technical solutions and safety concepts. Furthermore, recent clinically oriented studies are highlighted that span a broad application spectrum from 7T UHF brain to body MRI. 4 Technical Efficacy: Stage 1 J. Magn. Reson. Imaging 2017;46:1573-1589. © 2017 International Society for Magnetic Resonance in Medicine.

  14. The physics of MRI safety.

    PubMed

    Panych, Lawrence P; Madore, Bruno

    2018-01-01

    The main risks associated with magnetic resonance imaging (MRI) have been extensively reported and studied; for example, everyday objects may turn into projectiles, energy deposition can cause burns, varying fields can induce nerve stimulation, and loud noises can lead to auditory loss. The present review article is geared toward providing intuition about the physical mechanisms that give rise to these risks. On the one hand, excellent literature already exists on the practical aspect of risk management, with clinical workflow and recommendations. On the other hand, excellent technical articles also exist that explain these risks from basic principles of electromagnetism. We felt that an underserved niche might be found between the two, ie, somewhere between basic science and practical advice, to help develop intuition about electromagnetism that might prove of practical value when working around MR scanners. Following a wide-ranging introduction, risks originating from the main magnetic field, the excitation RF electromagnetic field, and switching of the imaging gradients will be presented in turn. 5 Technical Efficacy: 1 J. Magn. Reson. Imaging 2018;47:28-43. © 2017 International Society for Magnetic Resonance in Medicine.

  15. The influence of the current intensity on the damping characteristics for a magneto-rheological damper of passenger car

    NASA Astrophysics Data System (ADS)

    Dobre, A.; Andreescu, C. N.; Stan, C.

    2016-08-01

    Due to their simplicity and controllability, adaptive dampers became very popular in automotive engineering industry, especially in the passenger cars industry, in spite of technological obstacles inherent and the high cost of the magnetic fluid. “MagneRide” is the first technology which uses smart fluids in the shock absorbers of the vehicles adaptive suspensions. Since the discovery of the magneto-rheological effect there is a consistent progress regarding the control algorithms and hardware part itself. These magneto-rheological devices have a major potential which can be explored in various fields of applications. At present many companies make researches for the improvement of the response time and for obtaining a better response at low frequency and amplitude of the body car oscillations. The main objective of this paper is to determine the damping characteristic of a magnetorheological shock absorber of a passenger car. The authors aim to observe how to modify the damping characteristic by changing the intensity of the electric current. The experimental researches have being carried out on a complex and modern test bench especially built for testing shock absorbers, in order to compare the damping characteristic of the classical damper with the magneto-rheological damper.

  16. Passive radiofrequency shimming in the thighs at 3 Tesla using high permittivity materials and body coil receive uniformity correction.

    PubMed

    Brink, Wyger M; Versluis, Maarten J; Peeters, Johannes M; Börnert, Peter; Webb, Andrew G

    2016-12-01

    To explore the effects of high permittivity dielectric pads on the transmit and receive characteristics of a 3 Tesla body coil centered at the thighs, and their implications on image uniformity in receive array applications. Transmit and receive profiles of the body coil with and without dielectric pads were simulated and measured in healthy volunteers. Parallel imaging was performed using sensitivity encoding (SENSE) with and without pads. An intensity correction filter was constructed from the measured receive profile of the body coil. Measured and simulated data show that the dielectric pads improve the transmit homogeneity of the body coil in the thighs, but decrease its receive homogeneity, which propagates into reconstruction algorithms in which the body coil is used as a reference. However, by correcting for the body coil reception profile this effect can be mitigated. Combining high permittivity dielectric pads with an appropriate body coil receive sensitivity filter improves the image uniformity substantially compared with the situation without pads. Magn Reson Med 76:1951-1956, 2016. © 2015 International Society for Magnetic Resonance in Medicine. © 2015 International Society for Magnetic Resonance in Medicine.

  17. Sensitive enhancement of vessel wall imaging with an endoesophageal Wireless Amplified NMR Detector (WAND).

    PubMed

    Zeng, Xianchun; Barbic, Mladen; Chen, Liangliang; Qian, Chunqi

    2017-11-01

    To improve the imaging quality of vessel walls with an endoesophageal Wireless Amplified NMR Detector (WAND). A cylindrically shaped double-frequency resonator has been constructed with a single metal wire that is self-connected by a pair of nonlinear capacitors. The double-frequency resonator can convert wirelessly provided pumping power into amplified MR signals. This compact design makes the detector easily insertable into a rodent esophagus. The detector has good longitudinal and axial symmetry. Compared to an external surface coil, the WAND can enhance detection sensitivity by at least 5 times, even when the distance separation between the region of interest and the detector's cylindrical surface is twice the detector's own radius. Such detection capability enables us to observe vessel walls near the aortic arch and carotid bifurcation with elevated sensitivity. A cylindrical MRI detector integrated with a wireless-powered amplifier has been developed as an endoesophageal detector to enhance detection sensitivity of vessel walls. This detector can greatly improve the imaging quality for vessel regions that are susceptible to atherosclerotic lesions. Magn Reson Med 78:2048-2054, 2017. © 2016 International Society for Magnetic Resonance in Medicine. © 2016 International Society for Magnetic Resonance in Medicine.

  18. Fetal lung apparent diffusion coefficient measurement using diffusion-weighted MRI at 3 Tesla: Correlation with gestational age.

    PubMed

    Afacan, Onur; Gholipour, Ali; Mulkern, Robert V; Barnewolt, Carol E; Estroff, Judy A; Connolly, Susan A; Parad, Richard B; Bairdain, Sigrid; Warfield, Simon K

    2016-12-01

    To evaluate the feasibility of using diffusion-weighted magnetic resonance imaging (DW-MRI) to assess the fetal lung apparent diffusion coefficient (ADC) at 3 Tesla (T). Seventy-one pregnant women (32 second trimester, 39 third trimester) were scanned with a twice-refocused Echo-planar diffusion-weighted imaging sequence with 6 different b-values in 3 orthogonal diffusion orientations at 3T. After each scan, a region-of-interest (ROI) mask was drawn to select a region in the fetal lung and an automated robust maximum likelihood estimation algorithm was used to compute the ADC parameter. The amount of motion in each scan was visually rated. When scans with unacceptable levels of motion were eliminated, the lung ADC values showed a strong association with gestational age (P < 0.01), increasing dramatically between 16 and 27 weeks and then achieving a plateau around 27 weeks. We show that to get reliable estimates of ADC values of fetal lungs, a multiple b-value acquisition, where motion is either corrected or considered, can be performed. J. Magn. Reson. Imaging 2016;44:1650-1655. © 2016 International Society for Magnetic Resonance in Medicine.

  19. Resolving power for the diffusion orientation distribution function.

    PubMed

    Jensen, Jens H; Helpern, Joseph A

    2016-08-01

    The diffusion orientation distribution function (dODF) is primarily used for white matter fiber tractography. Here the resolving power of the dODF is investigated for a simple diffusion model of two intersecting axonal fiber bundles. The resolving power for the dODF is evaluated using the Sparrow criterion. This is determined for the exact dODF and also for q-space imaging (QSI), q-ball, and kurtosis approximations. Based on theoretical and numerical calculations, the resolving power is found to depend on the eigenvalues of the diffusion model and on the degree of radial weighting for the dODF. The resolving powers of the QSI and q-ball dODFs improve with increased b-value. The kurtosis dODF has a resolving power similar to that of the exact dODF. The dODFs, whether exact or approximate, have finite resolving powers that limit their sensitivity to fiber crossings. The resolving powers for the different dODFs considered here provide convenient benchmarks for assessing and comparing their performance. Magn Reson Med 76:679-688, 2016. © 2015 Wiley Periodicals, Inc. © 2015 Wiley Periodicals, Inc.

  20. Ramped-Amplitude Cross Polarization in Magic-Angle-Spinning NMR

    NASA Astrophysics Data System (ADS)

    Metz, G.; Wu, X. L.; Smith, S. O.

    The Hartmann-Hahn matching profile in CP-MAS NMR shows a strong mismatch dependence if the MAS frequency is on the order of the dipolar couplings in the sample. Under these conditions, the profile breaks down into a series of narrow matching bands separated by the spinning speed, and it becomes difficult to establish and maintain an efficient matching condition. Variable-amplitude CP (VACP), as introduced previously (Peersen et al., J. Magn. Reson. A104, 334, 1993), has been proven to be effective for restoring flat profiles at high spinning speeds. Here, a refined implementation of VACP using a ramped-amplitude cross-polarization sequence (RAMP-CP) is described. The order of the amplitude modulation is shown to be of importance for the cross-polarization process. The new pulse sequence with a linear amplitude ramp is not only easier to set up but also improves the performance of the variable-amplitude experiment in that it produces flat profiles over a wider range of matching conditions even with short total contact times. An increase in signal intensity is obtained compared to both con ventional CP and the originally proposed VACP sequence.

  1. Mapping immune cell infiltration using restricted diffusion MRI.

    PubMed

    Yeh, Fang-Cheng; Liu, Li; Hitchens, T Kevin; Wu, Yijen L

    2017-02-01

    Diffusion MRI provides a noninvasive way to assess tissue microstructure. Based on diffusion MRI, we propose a model-free method called restricted diffusion imaging (RDI) to quantify restricted diffusion and correlate it with cellularity. An analytical relation between q-space signals and the density of restricted spins was derived to quantify restricted diffusion. A phantom study was conducted to investigate the performance of RDI, and RDI was applied to an animal study to assess immune cell infiltration in myocardial tissues with ischemia-reperfusion injury. Our phantom study showed a correlation coefficient of 0.998 between cell density and the restricted diffusion quantified by RDI. The animal study also showed that the high-value regions in RDI matched well with the macrophage infiltration areas in the H&E stained slides. In comparison with diffusion tensor imaging (DTI), RDI exhibited its outperformance to detect macrophage infiltration and delineate inflammatory myocardium. RDI can be used to reveal cell density and detect immune cell infiltration. RDI exhibits better specificity than the diffusivity measurement derived from DTI. Magn Reson Med 77:603-612, 2017. © 2016 International Society for Magnetic Resonance in Medicine. © 2016 International Society for Magnetic Resonance in Medicine.

  2. Laplace Inversion of Low-Resolution NMR Relaxometry Data Using Sparse Representation Methods

    PubMed Central

    Berman, Paula; Levi, Ofer; Parmet, Yisrael; Saunders, Michael; Wiesman, Zeev

    2013-01-01

    Low-resolution nuclear magnetic resonance (LR-NMR) relaxometry is a powerful tool that can be harnessed for characterizing constituents in complex materials. Conversion of the relaxation signal into a continuous distribution of relaxation components is an ill-posed inverse Laplace transform problem. The most common numerical method implemented today for dealing with this kind of problem is based on L2-norm regularization. However, sparse representation methods via L1 regularization and convex optimization are a relatively new approach for effective analysis and processing of digital images and signals. In this article, a numerical optimization method for analyzing LR-NMR data by including non-negativity constraints and L1 regularization and by applying a convex optimization solver PDCO, a primal-dual interior method for convex objectives, that allows general linear constraints to be treated as linear operators is presented. The integrated approach includes validation of analyses by simulations, testing repeatability of experiments, and validation of the model and its statistical assumptions. The proposed method provides better resolved and more accurate solutions when compared with those suggested by existing tools. © 2013 Wiley Periodicals, Inc. Concepts Magn Reson Part A 42A: 72–88, 2013. PMID:23847452

  3. Automated Purification of Recombinant Proteins: Combining High-throughput with High Yield

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Lin, Chiann Tso; Moore, Priscilla A.; Auberry, Deanna L.

    2006-05-01

    Protein crystallography, mapping protein interactions and other approaches of current functional genomics require not only purifying large numbers of proteins but also obtaining sufficient yield and homogeneity for downstream high-throughput applications. There is a need for the development of robust automated high-throughput protein expression and purification processes to meet these requirements. We developed and compared two alternative workflows for automated purification of recombinant proteins based on expression of bacterial genes in Escherichia coli: First - a filtration separation protocol based on expression of 800 ml E. coli cultures followed by filtration purification using Ni2+-NTATM Agarose (Qiagen). Second - a smallermore » scale magnetic separation method based on expression in 25 ml cultures of E.coli followed by 96-well purification on MagneHisTM Ni2+ Agarose (Promega). Both workflows provided comparable average yields of proteins about 8 ug of purified protein per unit of OD at 600 nm of bacterial culture. We discuss advantages and limitations of the automated workflows that can provide proteins more than 90 % pure in the range of 100 ug – 45 mg per purification run as well as strategies for optimization of these protocols.« less

  4. In vivo estimation of transverse relaxation time constant (T2 ) of 17 human brain metabolites at 3T.

    PubMed

    Wyss, Patrik O; Bianchini, Claudio; Scheidegger, Milan; Giapitzakis, Ioannis A; Hock, Andreas; Fuchs, Alexander; Henning, Anke

    2018-08-01

    The transverse relaxation times T 2 of 17 metabolites in vivo at 3T is reported and region specific differences are addressed. An echo-time series protocol was applied to one, two, or three volumes of interest with different fraction of white and gray matter including a total number of 106 healthy volunteers and acquiring a total number of 128 spectra. The data were fitted with the 2D fitting tool ProFit2, which included individual line shape modeling for all metabolites and allowed the T 2 calculation of 28 moieties of 17 metabolites. The T 2 of 10 metabolites and their moieties have been reported for the first time. Region specific T 2 differences in white and gray matter enriched tissue occur in 16 of 17 metabolites examined including single resonance lines and coupled spin systems. The relaxation time T 2 is regions specific and has to be considered when applying tissue composition correction for internal water referencing. Magn Reson Med 80:452-461, 2018. © 2018 International Society for Magnetic Resonance in Medicine. © 2018 International Society for Magnetic Resonance in Medicine.

  5. Improved convection compensating pulsed field gradient spin-echo and stimulated-echo methods.

    PubMed

    Sørland, G H; Seland, J G; Krane, J; Anthonsen, H W

    2000-02-01

    The need for convection compensating methods in NMR has been manifested through an increasing number of publications related to the subject over the past few years (J. Magn. Reson. 125, 372 (1997); 132, 13 (1998); 131, 126 (1998); 118, 50 (1996); 133, 379 (1998)). When performing measurements at elevated temperature, small convection currents may give rise to erroneous values of the diffusion coefficient. In work with high resolution NMR spectroscopy, the application of magnetic field gradients also introduces an eddy-current magnetic field which may result in errors in phase and baseline in the FFT-spectra. The eddy current field has been greatly suppressed by the application of bipolar magnetic field gradients. However, when introducing bipolar magnetic field gradients, the pulse sequence is lengthened significantly. This has recently been pointed out as a major drawback because of the loss of coherence and of NMR-signal due to transverse relaxation processes. Here we present modified convection compensating pulsed field gradient double spin echo and double stimulated echo sequences which suppress the eddy-current magnetic field without increasing the duration of the pulse sequences. Copyright 2000 Academic Press.

  6. Applications for a hybrid operating room in thoracic surgery: from multidisciplinary procedures to --image-guided video-assisted thoracoscopic surgery.

    PubMed

    Terra, Ricardo Mingarini; Andrade, Juliano Ribeiro; Mariani, Alessandro Wasum; Garcia, Rodrigo Gobbo; Succi, Jose Ernesto; Soares, Andrey; Zimmer, Paulo Marcelo

    2016-01-01

    The concept of a hybrid operating room represents the union of a high-complexity surgical apparatus with state-of-the-art radiological tools (ultrasound, CT, fluoroscopy, or magnetic resonance imaging), in order to perform highly effective, minimally invasive procedures. Although the use of a hybrid operating room is well established in specialties such as neurosurgery and cardiovascular surgery, it has rarely been explored in thoracic surgery. Our objective was to discuss the possible applications of this technology in thoracic surgery, through the reporting of three cases. RESUMO O conceito de sala híbrida traduz a união de um aparato cirúrgico de alta complexidade com recursos radiológicos de última geração (ultrassom, TC, radioscopia e/ou ressonância magnética), visando a realização de procedimentos minimamente invasivos e altamente eficazes. Apesar de bem estabelecido em outras especialidades, como neurocirurgia e cirurgia cardiovascular, o uso da sala hibrida ainda é pouco explorado na cirurgia torácica. Nosso objetivo foi discutir as aplicações e as possibilidades abertas por essa tecnologia na cirurgia torácica através do relato de três casos.

  7. Des schémas équivalents pour les circuits couplés multi-enroulements

    NASA Astrophysics Data System (ADS)

    Keradec, J. P.; Cogitore, B.; Laveuve, E.; Bensoam, M.

    1994-04-01

    The aim of this paper is to represent the electrical behaviour of any number of magnetically coupled windings with couplers and inductors. Two methods, mathematicaly justified, are proposed. The second one introduces only positive inductances. As an exemple, it is applied to the representation of a three column three phase transformer. The obtained circuits supply the requisite guide to design more complete circuits which allow the high frequency behaviour of wound components to be taken into account, especialy in electronics simulation softwares. Le but de cet article est de traduire le comportement électrique d'un nombre quelconque d'enroulements magnétiquement couplés, par des coupleurs et des inductances. Deux méthodes, établies mathématiquement, sont proposées. La seconde n'introduit que des inductances positives. A titre d'exemple, elle est appliquée à la représentation d'un transformateur triphasé à trois colonnes. Les schémas obtenus fournissent l'indispensable ossature de schémas plus complets, aptes à représenter le comportement haute fréquence des composants bobinés, notamment dans un logiciel de simulation électronique.

  8. Accelerating cine-MR Imaging in Mouse Hearts Using Compressed Sensing

    PubMed Central

    Wech, Tobias; Lemke, Angela; Medway, Debra; Stork, Lee-Anne; Lygate, Craig A; Neubauer, Stefan; Köstler, Herbert; Schneider, Jürgen E

    2011-01-01

    Purpose To combine global cardiac function imaging with compressed sensing (CS) in order to reduce scan time and to validate this technique in normal mouse hearts and in a murine model of chronic myocardial infarction. Materials and Methods To determine the maximally achievable acceleration factor, fully acquired cine data, obtained in sham and chronically infarcted (MI) mouse hearts were 2–4-fold undersampled retrospectively, followed by CS reconstruction and blinded image segmentation. Subsequently, dedicated CS sampling schemes were implemented at a preclinical 9.4 T magnetic resonance imaging (MRI) system, and 2- and 3-fold undersampled cine data were acquired in normal mouse hearts with high temporal and spatial resolution. Results The retrospective analysis demonstrated that an undersampling factor of three is feasible without impairing accuracy of cardiac functional parameters. Dedicated CS sampling schemes applied prospectively to normal mouse hearts yielded comparable left-ventricular functional parameters, and intra- and interobserver variability between fully and 3-fold undersampled data. Conclusion This study introduces and validates an alternative means to speed up experimental cine-MRI without the need for expensive hardware. J. Magn. Reson. Imaging 2011. © 2011 Wiley Periodicals, Inc. PMID:21932360

  9. Off-resonance R1rho relaxation outside of the fast exchange limit: an experimental study of a cavity mutant of T4 lysozyme.

    PubMed

    Korzhnev, Dmitry M; Orekhov, Vladislav Yu; Dahlquist, Frederick W; Kay, Lewis E

    2003-05-01

    An (15)N off-resonance R(1rho) spin relaxation study of an L99A point mutant of T4 lysozyme is presented. Previous CPMG-based relaxation dispersion studies of exchange in this protein have established that the molecule interconverts between a populated ground state and an excited state (3.4%) with an exchange rate constant of 1450 s(-1) at 25 degrees C. It is shown that for the majority of residues in this protein the offset dependence of the R(1rho) relaxation rates cannot be well fit using models which are only valid in the fast exchange regime. In contrast, a recently derived expression by Trott and Palmer (J. Magn. Reson., 154, 157-160, 2002) which is valid over a wider window of exchange than other relations, is shown to fit the data well. Values of (signed) chemical shift differences between exchanging sites have been extracted and are in reasonable agreement with shift differences measured using CPMG methods. A set of simulations is presented which help establish the exchange regimes that are best suited to analysis by off-resonance R(1rho) techniques.

  10. Laplace Inversion of Low-Resolution NMR Relaxometry Data Using Sparse Representation Methods.

    PubMed

    Berman, Paula; Levi, Ofer; Parmet, Yisrael; Saunders, Michael; Wiesman, Zeev

    2013-05-01

    Low-resolution nuclear magnetic resonance (LR-NMR) relaxometry is a powerful tool that can be harnessed for characterizing constituents in complex materials. Conversion of the relaxation signal into a continuous distribution of relaxation components is an ill-posed inverse Laplace transform problem. The most common numerical method implemented today for dealing with this kind of problem is based on L 2 -norm regularization. However, sparse representation methods via L 1 regularization and convex optimization are a relatively new approach for effective analysis and processing of digital images and signals. In this article, a numerical optimization method for analyzing LR-NMR data by including non-negativity constraints and L 1 regularization and by applying a convex optimization solver PDCO, a primal-dual interior method for convex objectives, that allows general linear constraints to be treated as linear operators is presented. The integrated approach includes validation of analyses by simulations, testing repeatability of experiments, and validation of the model and its statistical assumptions. The proposed method provides better resolved and more accurate solutions when compared with those suggested by existing tools. © 2013 Wiley Periodicals, Inc. Concepts Magn Reson Part A 42A: 72-88, 2013.

  11. Iron deposition quantification: Applications in the brain and liver.

    PubMed

    Yan, Fuhua; He, Naying; Lin, Huimin; Li, Ruokun

    2018-06-13

    Iron has long been implicated in many neurological and other organ diseases. It is known that over and above the normal increases in iron with age, in certain diseases there is an excessive iron accumulation in the brain and liver. MRI is a noninvasive means by which to image the various structures in the brain in three dimensions and quantify iron over the volume of the object of interest. The quantification of iron can provide information about the severity of iron-related diseases as well as quantify changes in iron for patient follow-up and treatment monitoring. This article provides an overview of current MRI-based methods for iron quantification, specifically for the brain and liver, including: signal intensity ratio, R 2 , R2*, R2', phase, susceptibility weighted imaging and quantitative susceptibility mapping (QSM). Although there are numerous approaches to measuring iron, R 2 and R2* are currently preferred methods in imaging the liver and QSM has become the preferred approach for imaging iron in the brain. 5 Technical Efficacy: Stage 5 J. Magn. Reson. Imaging 2018. © 2018 International Society for Magnetic Resonance in Medicine.

  12. Single atomic particle at rest in free space : new value for electron radius

    NASA Astrophysics Data System (ADS)

    Dehmelt, H.

    -ion oscillator, but using Tl+ or a similar ion, may make an optical frequency standard with a 1 000-day reproducibility of 10 -18 possible and thereby allow one to watch the expansion of the universe from one's laboratory. Nous décrivons brièvement l'équivalent quantique d'une particule classique unique au repos dans l'espace libre : le confinement de point zéro dans un piège. Jusqu'à maintenant, ce confinement n'a été réalisé que pour le mouvement cyclotron (150 GHz) du géonium. un électron unique confiné dans un piège de Penning. Le résultat le plus important de la spectroscopie de particules piégées est un nouveau rayon de l'électron, 10 000 fois plus petit. Ce résultat a été obtenu à partir des données concernant le facteur g, g/2 = 1,001 159 652 193 (4), et sur la base d'un modèle de particule voisin du modèle de Dirac. La spectroscopie RF du géonium repose à l'heure actuelle sur l'effet Stern et Gerlach continu, dans lequel un basculement de spin est détecté grâce au faible changement qu'il induit sur la fréquence d'oscillation axiale de l'électron dans le piège (60 MHz). La variation relativiste de la masse, ou effet Kaufmann, pourrait s'avérer être à la base d'une méthode plus sensible : l'utilisation du géonium comme un mini-synchro-cyclotron sélectif en fréquence permet en effet de produire un déplacement aisément détectable de la fréquence axiale. Comme dans le magnétron « split-anode » de Habann (1926), l'énergie est rapidement transférée de l'électron oscillant vers un circuit résonnant, ce transfert servant dans notre expérience à la détection, au freinage et au refroidissement du mouvement oscillant. Nous avons ainsi pu localiser l'électron sur 60 μm, au nœud d'une onde stationnaire formée dans la cavité du piège, cette cavité étant résonnante et se comportant alors comme un court-circuit; ceci a permis une diminution de la largeur naturelle de la raie détectée par un facteur 10. En excitant le

  13. Optical clearing of the dura mater using glycerol: a reversible process to aid the post-mortem investigation of infant head injury.

    PubMed

    Cheshire, Emma C; Malcomson, Roger D G; Joseph, Shiju; Biggs, Mike J B; Adlam, David; Rutty, Guy N

    2015-09-01

    In cases of suspected abusive head trauma, a thorough and systematic study of the cranium and its contents is essential, preferably using the best available methods for observing the brain and its coverings. Building upon recent developments in skull bone removal techniques in infant autopsies, we have assessed the use of two optical clearing agents (OCAs), glycerol and mannitol, on pediatric dura mater in an attempt to increase the transparency of this tissue and thereby enhance the post-mortem assessment of infant head injuries, particularly subdural hematomas. Extracorporeal testing revealed glycerol to be the more effective OCA. Therefore, in situ investigations were commenced using glycerol during 33 pediatric post-mortem examinations. An increase in the transparency of the dura was observed in 32 of the 33 cases, within 1 min of application of the OCA. In a 2 year old with cerebral palsy, only partial optical clearance of the dura was seen, most likely due to a significantly atrophic brain, prominent gelatinous leptomeninges, and abnormally thickened dura. This technique allowed for detection of minimal amounts of subdural bleeding over the convexities, before dissection of the dura, avoiding post-mortem blood spillage from artifactually disrupted bridging veins. Optical clearing of the dura aided in the evaluation of patterns of subdural hemorrhage in three cases of non-accidental head injury, three cases of peri-natal head injury and one case of overlaying, apparently resulting in minor crush injury to the head. We have demonstrated that glycerol is an effective and easy-to-use OCA to effect the readily reversible optical clearing of human infant calvarial dura at autopsy.

  14. Modélisation magnétotellurique de la structure géologique profonde de l’unité granulitique de l’In Ouzzal (Hoggar occidental)

    NASA Astrophysics Data System (ADS)

    Bouzid, Abderrezak; Akacem, Nouredine; Hamoudi, Mohamed; Ouzegane, Khadidja; Abtout, Abdeslam; Kienast, Jean-Robert

    2008-11-01

    Magnetotelluric modeling of the deep geologic structure of In Ouzzal Granulitic Unit (western Hoggar). The In Ouzzal Granulitic Unit (IOGU) or In Ouzzal Terrane (IOT) is an Archaean block belonging to the Hoggar terrane mosaic. It has been reworked during the Eburnean and is characterized by ultrahigh temperature metamorphism of the structures, which are likely to be old dome and basin structures. The aim of this study, based on a survey of 12 magnetotelluric (MT) soundings, was to characterize the IOGU deep lateral boundaries and to see if it is possible to reconstruct some of these old dome and basin structures after their transformation by metamorphism and deformation. MT data analysis and modeling show that IOGU boundaries extend downwards, at least down to the crust's basement, and may represent suture zones. Inside the terrane, the MT observations do not allow separation between dome and basin structures, because these features are severely stretched. However, the main MT transverse response feature is a deeply rooted great accident, which may be interpreted as a major fault that separates IOGU into two compartments.

  15. Magnetic susceptibility and AMS of the Bushveld alkaline granites, South Africa

    NASA Astrophysics Data System (ADS)

    Ferré, Eric C.; Wilson, Jeff; Gleizes, Gérard

    1999-06-01

    The Bushveld Complex in South Africa includes one of the world's largest anorogenic alkaline granite intrusions (66,000 km 2). The granite forms a composite laccolith, of 350 × 250 km in area and about 2 km in thickness, which was emplaced at about 5 km depth into sediments overlying the Kaapvaal craton, at 2054 Ma. The Bushveld granite and its roof-rocks have long been mined for Sn, W and F. The Bushveld granites have high magnetic susceptibilities ( Km from 1000 to 4000 μSI), and a quantitative model is presented, suggesting that susceptibility fabrics are primarily carried by ferromagnetic minerals. The measured AMS foliations coincide with observed subhorizontal mineral lineations and compositional layering. Magnetic lineation trends vary considerably within the horizontal plane. The existence of a weak planar fabric and, an almost absent linear component may reflect (a) laccolithic emplacement by roof uplift, causing flattening magmatic fabrics, or (b) emplacement of largely crystal-free magma crystallizing in-situ and developing horizontal compositional layering from thermal chemical diffusion fronts and gravity-driven mechanisms. Weak magnétic fabrics, like those identified in the Bushveld granites require specific sampling schemes and procedures, in addition to rigorous constraint of magnetic mineralogy and crystallization sequence.

  16. ISMRM Raw data format: A proposed standard for MRI raw datasets.

    PubMed

    Inati, Souheil J; Naegele, Joseph D; Zwart, Nicholas R; Roopchansingh, Vinai; Lizak, Martin J; Hansen, David C; Liu, Chia-Ying; Atkinson, David; Kellman, Peter; Kozerke, Sebastian; Xue, Hui; Campbell-Washburn, Adrienne E; Sørensen, Thomas S; Hansen, Michael S

    2017-01-01

    This work proposes the ISMRM Raw Data format as a common MR raw data format, which promotes algorithm and data sharing. A file format consisting of a flexible header and tagged frames of k-space data was designed. Application Programming Interfaces were implemented in C/C++, MATLAB, and Python. Converters for Bruker, General Electric, Philips, and Siemens proprietary file formats were implemented in C++. Raw data were collected using magnetic resonance imaging scanners from four vendors, converted to ISMRM Raw Data format, and reconstructed using software implemented in three programming languages (C++, MATLAB, Python). Images were obtained by reconstructing the raw data from all vendors. The source code, raw data, and images comprising this work are shared online, serving as an example of an image reconstruction project following a paradigm of reproducible research. The proposed raw data format solves a practical problem for the magnetic resonance imaging community. It may serve as a foundation for reproducible research and collaborations. The ISMRM Raw Data format is a completely open and community-driven format, and the scientific community is invited (including commercial vendors) to participate either as users or developers. Magn Reson Med 77:411-421, 2017. © 2016 Wiley Periodicals, Inc. © 2016 Wiley Periodicals, Inc.

  17. MRS of pilocytic astrocytoma: The peak at 2 ppm may not be NAA.

    PubMed

    Tamrazi, Benita; Nelson, Marvin D; Blüml, Stefan

    2017-08-01

    To determine whether the chemical shift of residual N-acetylaspartate (NAA) signal in pilocytic astrocytomas (PA) is consistent with the position of the NAA peak in controls. MR spectra from 27 pediatric World Health Organization (WHO) grade I pilocytic astrocytoma patients, fifteen patients with WHO grade II and high-grade (III-IV) astrocytomas, and 36 controls were analyzed. All spectra were acquired with a short echo time (35 ms), single voxel point-resolved spectroscopy sequence on clinical 3 tesla scanners. Fully automated LCModel software was used for processing, which included the fitting of peak positions for NAA and creatine (Cr). The chemical shift difference between the NAA and Cr peaks was significantly smaller (by 0.016 ± 0.005 parts per million, P < 1e-10) in PAs than in controls and was also smaller than what was observed in infiltrative astrocytomas. The chemical shift position of the residual NAA peak in PAs is not consistent with NAA. The signal likely originates from an N-acetyl group of one or more other chemicals such as N-acetylated sugars. Magn Reson Med 78:452-456, 2017. © 2016 International Society for Magnetic Resonance in Medicine. © 2016 International Society for Magnetic Resonance in Medicine.

  18. Resistance switching behavior of atomic layer deposited SrTiO3 film through possible formation of Sr2Ti6O13 or Sr1Ti11O20 phases

    PubMed Central

    Lee, Woongkyu; Yoo, Sijung; Yoon, Kyung Jean; Yeu, In Won; Chang, Hye Jung; Choi, Jung-Hae; Hoffmann-Eifert, Susanne; Waser, Rainer; Hwang, Cheol Seong

    2016-01-01

    Identification of microstructural evolution of nanoscale conducting phase, such as conducting filament (CF), in many resistance switching (RS) devices is a crucial factor to unambiguously understand the electrical behaviours of the RS-based electronic devices. Among the diverse RS material systems, oxide-based redox system comprises the major category of these intriguing electronic devices, where the local, along both lateral and vertical directions of thin films, changes in oxygen chemistry has been suggested to be the main RS mechanism. However, there are systems which involve distinctive crystallographic phases as CF; the Magnéli phase in TiO2 is one of the very well-known examples. The current research reports the possible presence of distinctive local conducting phase in atomic layer deposited SrTiO3 RS thin film. The conducting phase was identified through extensive transmission electron microscopy studies, which indicated that oxygen-deficient Sr2Ti6O13 or Sr1Ti11O20 phase was presumably present mainly along the grain boundaries of SrTiO3 after the unipolar set switching in Pt/TiN/SrTiO3/Pt structure. A detailed electrical characterization revealed that the samples showed typical bipolar and complementary RS after the memory cell was unipolar reset. PMID:26830978

  19. A z-gradient array for simultaneous multi-slice excitation with a single-band RF pulse.

    PubMed

    Ertan, Koray; Taraghinia, Soheil; Sadeghi, Alireza; Atalar, Ergin

    2018-07-01

    Multi-slice radiofrequency (RF) pulses have higher specific absorption rates, more peak RF power, and longer pulse durations than single-slice RF pulses. Gradient field design techniques using a z-gradient array are investigated for exciting multiple slices with a single-band RF pulse. Two different field design methods are formulated to solve for the required current values of the gradient array elements for the given slice locations. The method requirements are specified, optimization problems are formulated for the minimum current norm and an analytical solution is provided. A 9-channel z-gradient coil array driven by independent, custom-designed gradient amplifiers is used to validate the theory. Performance measures such as normalized slice thickness error, gradient strength per unit norm current, power dissipation, and maximum amplitude of the magnetic field are provided for various slice locations and numbers of slices. Two and 3 slices are excited by a single-band RF pulse in simulations and phantom experiments. The possibility of multi-slice excitation with a single-band RF pulse using a z-gradient array is validated in simulations and phantom experiments. Magn Reson Med 80:400-412, 2018. © 2017 International Society for Magnetic Resonance in Medicine. © 2017 International Society for Magnetic Resonance in Medicine.

  20. Relaxometry model of strong dipolar perturbers for balanced-SSFP: application to quantification of SPIO loaded cells.

    PubMed

    Lebel, R Marc; Menon, Ravi S; Bowen, Chris V

    2006-03-01

    Magnetic resonance microscopy using magnetically labeled cells is an emerging discipline offering the potential for non-destructive studies targeting numerous cellular events in medical research. The present work develops a technique to quantify superparamagnetic iron-oxide (SPIO) loaded cells using fully balanced steady state free precession (b-SSFP) imaging. An analytic model based on phase cancellation was derived for a single particle and extended to predict mono-exponential decay versus echo time in the presence of multiple randomly distributed particles. Numerical models verified phase incoherence as the dominant contrast mechanism and evaluated the model using a full range of tissue decay rates, repetition times, and flip angles. Numerical simulations indicated a relaxation rate enhancement (DeltaR(2b)=0.412 gamma . LMD) proportional to LMD, the local magnetic dose (the additional sample magnetization due to the SPIO particles), a quantity related to the concentration of contrast agent. A phantom model of SPIO loaded cells showed excellent agreement with simulations, demonstrated comparable sensitivity to gradient echo DeltaR(*) (2) enhancements, and 14 times the sensitivity of spin echo DeltaR(2) measurements. We believe this model can be used to facilitate the generation of quantitative maps of targeted cell populations. Magn Reson Med, 2006. (c) 2006 Wiley-Liss, Inc.

  1. Characterization of anomalous relaxation using the time-fractional Bloch equation and multiple echo T2 *-weighted magnetic resonance imaging at 7 T.

    PubMed

    Qin, Shanlin; Liu, Fawang; Turner, Ian W; Yu, Qiang; Yang, Qianqian; Vegh, Viktor

    2017-04-01

    To study the utility of fractional calculus in modeling gradient-recalled echo MRI signal decay in the normal human brain. We solved analytically the extended time-fractional Bloch equations resulting in five model parameters, namely, the amplitude, relaxation rate, order of the time-fractional derivative, frequency shift, and constant offset. Voxel-level temporal fitting of the MRI signal was performed using the classical monoexponential model, a previously developed anomalous relaxation model, and using our extended time-fractional relaxation model. Nine brain regions segmented from multiple echo gradient-recalled echo 7 Tesla MRI data acquired from five participants were then used to investigate the characteristics of the extended time-fractional model parameters. We found that the extended time-fractional model is able to fit the experimental data with smaller mean squared error than the classical monoexponential relaxation model and the anomalous relaxation model, which do not account for frequency shift. We were able to fit multiple echo time MRI data with high accuracy using the developed model. Parameters of the model likely capture information on microstructural and susceptibility-induced changes in the human brain. Magn Reson Med 77:1485-1494, 2017. © 2016 International Society for Magnetic Resonance in Medicine. © 2016 International Society for Magnetic Resonance in Medicine.

  2. Inversion group (IG) fitting: A new T1 mapping method for modified look-locker inversion recovery (MOLLI) that allows arbitrary inversion groupings and rest periods (including no rest period).

    PubMed

    Sussman, Marshall S; Yang, Issac Y; Fok, Kai-Ho; Wintersperger, Bernd J

    2016-06-01

    The Modified Look-Locker Inversion Recovery (MOLLI) technique is used for T1 mapping in the heart. However, a drawback of this technique is that it requires lengthy rest periods in between inversion groupings to allow for complete magnetization recovery. In this work, a new MOLLI fitting algorithm (inversion group [IG] fitting) is presented that allows for arbitrary combinations of inversion groupings and rest periods (including no rest period). Conventional MOLLI algorithms use a three parameter fitting model. In IG fitting, the number of parameters is two plus the number of inversion groupings. This increased number of parameters permits any inversion grouping/rest period combination. Validation was performed through simulation, phantom, and in vivo experiments. IG fitting provided T1 values with less than 1% discrepancy across a range of inversion grouping/rest period combinations. By comparison, conventional three parameter fits exhibited up to 30% discrepancy for some combinations. The one drawback with IG fitting was a loss of precision-approximately 30% worse than the three parameter fits. IG fitting permits arbitrary inversion grouping/rest period combinations (including no rest period). The cost of the algorithm is a loss of precision relative to conventional three parameter fits. Magn Reson Med 75:2332-2340, 2016. © 2015 Wiley Periodicals, Inc. © 2015 Wiley Periodicals, Inc.

  3. A monte carlo study of restricted diffusion: Implications for diffusion MRI of prostate cancer.

    PubMed

    Gilani, Nima; Malcolm, Paul; Johnson, Glyn

    2017-04-01

    Diffusion MRI is used frequently to assess prostate cancer. The prostate consists of cellular tissue surrounding fluid filled ducts. Here, the diffusion properties of the ductal fluid alone were studied. Monte Carlo simulations were used to investigate ductal residence times to determine whether ducts can be regarded as forming a separate compartment and whether ductal radius could determine the Apparent Diffusion Coefficient (ADC) of the ductal fluid. Random walks were simulated in cavities. Average residence times were estimated for permeable cavities. Signal reductions resulting from application of a Stejskal-Tanner pulse sequence were calculated in impermeable cavities. Simulations were repeated for cavities of different radii and different diffusion times. Residence times are at least comparable with diffusion times even in relatively high grade tumors. ADCs asymptotically approach theoretical limiting values. At large radii and short diffusion times, ADCs are similar to free diffusion. At small radii and long diffusion times, ADCs are reduced toward zero, and kurtosis approaches a value of -1.2. Restricted diffusion in cavities of similar sizes to prostate ducts may reduce ductal ADCs. This may contribute to reductions in total ADC seen in prostate cancer. Magn Reson Med 77:1671-1677, 2017. © 2016 International Society for Magnetic Resonance in Medicine. © 2016 International Society for Magnetic Resonance in Medicine.

  4. Thermal noise variance of a receive radiofrequency coil as a respiratory motion sensor.

    PubMed

    Andreychenko, A; Raaijmakers, A J E; Sbrizzi, A; Crijns, S P M; Lagendijk, J J W; Luijten, P R; van den Berg, C A T

    2017-01-01

    Development of a passive respiratory motion sensor based on the noise variance of the receive coil array. Respiratory motion alters the body resistance. The noise variance of an RF coil depends on the body resistance and, thus, is also modulated by respiration. For the noise variance monitoring, the noise samples were acquired without and with MR signal excitation on clinical 1.5/3 T MR scanners. The performance of the noise sensor was compared with the respiratory bellow and with the diaphragm displacement visible on MR images. Several breathing patterns were tested. The noise variance demonstrated a periodic, temporal modulation that was synchronized with the respiratory bellow signal. The modulation depth of the noise variance resulting from the respiration varied between the channels of the array and depended on the channel's location with respect to the body. The noise sensor combined with MR acquisition was able to detect the respiratory motion for every k-space read-out line. Within clinical MR systems, the respiratory motion can be detected by the noise in receive array. The noise sensor does not require careful positioning unlike the bellow, any additional hardware, and/or MR acquisition. Magn Reson Med 77:221-228, 2017. © 2016 Wiley Periodicals, Inc. © 2016 Wiley Periodicals, Inc.

  5. Parameter estimation using weighted total least squares in the two-compartment exchange model.

    PubMed

    Garpebring, Anders; Löfstedt, Tommy

    2018-01-01

    The linear least squares (LLS) estimator provides a fast approach to parameter estimation in the linearized two-compartment exchange model. However, the LLS method may introduce a bias through correlated noise in the system matrix of the model. The purpose of this work is to present a new estimator for the linearized two-compartment exchange model that takes this noise into account. To account for the noise in the system matrix, we developed an estimator based on the weighted total least squares (WTLS) method. Using simulations, the proposed WTLS estimator was compared, in terms of accuracy and precision, to an LLS estimator and a nonlinear least squares (NLLS) estimator. The WTLS method improved the accuracy compared to the LLS method to levels comparable to the NLLS method. This improvement was at the expense of increased computational time; however, the WTLS was still faster than the NLLS method. At high signal-to-noise ratio all methods provided similar precisions while inconclusive results were observed at low signal-to-noise ratio. The proposed method provides improvements in accuracy compared to the LLS method, however, at an increased computational cost. Magn Reson Med 79:561-567, 2017. © 2017 International Society for Magnetic Resonance in Medicine. © 2017 International Society for Magnetic Resonance in Medicine.

  6. Prestructural cartilage assessment using MRI.

    PubMed

    Link, Thomas M; Neumann, Jan; Li, Xiaojuan

    2017-04-01

    Cartilage loss is irreversible, and to date, no effective pharmacotherapies are available to protect or regenerate cartilage. Quantitative prestructural/compositional MR imaging techniques have been developed to characterize the cartilage matrix quality at a stage where abnormal findings are early and potentially reversible, allowing intervention to halt disease progression. The goal of this article is to critically review currently available technologies, present the basic concept behind these techniques, but also to investigate their suitability as imaging biomarkers including their validity, reproducibility, risk prediction and monitoring of therapy. Moreover, we highlighted important clinical applications. This review article focuses on the currently most relevant and clinically applicable technologies, such as T2 mapping, T2*, T1ρ, delayed gadolinium enhanced MRI of cartilage (dGEMRIC), sodium imaging and glycosaminoglycan chemical exchange saturation transfer (gagCEST). To date, most information is available for T2 and T1ρ mapping. dGEMRIC has also been used in multiple clinical studies, although it requires Gd contrast administration. Sodium imaging and gagCEST are promising technologies but are dependent on high field strength and sophisticated software and hardware. 5 J. Magn. Reson. Imaging 2017;45:949-965. © 2016 International Society for Magnetic Resonance in Medicine.

  7. Antisuperconductors: Properties of Layered Compounds with Coupling

    NASA Astrophysics Data System (ADS)

    Carton, J.-P.; Lammert, P. E.; Prost, J.

    1995-11-01

    In this note, we consider properties of a hypothetical superconductor composed of Josephson-coupled microscopic layers with tunneling energy minimized at a phase difference of π. The non-zero phase offset in the ground state engenders an intriguing interplay between the superconductive ordering and structural lattice defects. Unusual magnetic properties are expected in the case of highly disordered crystals, which are consistent with observations of a “paramagnetic Meissner” or “Wohlleben” effect in high-T_c cuprate superconductors. Dans cette note, nous considérons les propriétés d'un supraconducteur hypothétique composé de couches microscopiques, couplées par effet Josephson, mais dont l'énergie de couplage est minimisée pour une différence de phase de π. L'état de base a des propriétés fascinantes dues à l'effet combiné de l'ordre supraconducteur et des défauts structuraux du cristal. Dans le cas de cristaux très désordonnés, on attend des propriétés magnétiques exceptionnelles, qui sont compatibles avec les observations dans quelques supraconducteurs cuprate haute-T_c d'un effet “Meissner paramagnétique” ou “Wohlleben”.

  8. 43Ca NMR in solid state

    NASA Astrophysics Data System (ADS)

    Bellot, P.-V.; Trokiner, A.; Zhdanov, Yu.; Yakubovskii, A.

    1998-02-01

    In this paper we show that 43Ca is a suitable NMR probe to study the properties of high-Tc superconducting oxides. In the normal state, we report the temperature and doping dependencies of the spin susceptibility measured by 43Ca NMR. In the superconducting state and more exactly in the mixed state, by analysing 43Ca NMR linewidth, we have studied the magnetic induction distribution due to the presence of vortices and deduced λ, the penetration depth. Dans cet article, on montre que l'isotope 43 du calcium est une bonne sonde RMN pour l'étude des propriétés des oxydes supraconducteurs à haute température. Dans l'état normal, par la détermination du déplacement de la raie, en fonction de la température, on accède à la variation thermique de la susceptibilité de spin. Dans l'état supraconducteur et plus particulièrement dans l'état mixte, la largeur de raie RMN permet d'étudier la distribution d'induction magnétique due à la présence des vortex et de déterminer λ, la longueur de pénétration.

  9. Joint analysis of ESR lineshapes and 1H NMRD profiles of DOTA-Gd derivatives by means of the slow motion theory

    NASA Astrophysics Data System (ADS)

    Kruk, D.; Kowalewski, J.; Tipikin, D. S.; Freed, J. H.; Mościcki, M.; Mielczarek, A.; Port, M.

    2011-01-01

    The "Swedish slow motion theory" [Nilsson and Kowalewski, J. Magn. Reson. 146, 345 (2000)] applied so far to Nuclear Magnetic Relaxation Dispersion (NMRD) profiles for solutions of transition metal ion complexes has been extended to ESR spectral analysis, including in addition g-tensor anisotropy effects. The extended theory has been applied to interpret in a consistent way (within one set of parameters) NMRD profiles and ESR spectra at 95 and 237 GHz for two Gd(III) complexes denoted as P760 and P792 (hydrophilic derivatives of DOTA-Gd, with molecular masses of 5.6 and 6.5 kDa, respectively). The goal is to verify the applicability of the commonly used pseudorotational model of the transient zero field splitting (ZFS). According to this model the transient ZFS is described by a tensor of a constant amplitude, defined in its own principal axes system, which changes its orientation with respect to the laboratory frame according to the isotropic diffusion equation with a characteristic time constant (correlation time) reflecting the time scale of the distortional motion. This unified interpretation of the ESR and NMRD leads to reasonable agreement with the experimental data, indicating that the pseudorotational model indeed captures the essential features of the electron spin dynamics.

  10. Magnetization hysteresis electron paramagnetic resonance. A new null phase insensitive saturation transfer EPR technique with high sensitivity to slow motion.

    PubMed Central

    Vistnes, A I

    1983-01-01

    In electron paramagnetic resonance (EPR) nonlinear phenomena with respect to magnetic-field modulation are often studied by out-of-phase spectra recordings. The existence of a nonzero out-of-phase signal implies that the EPR signal is phase shifted relative to the modulation signal. This phase shift is called a magnetization hysteresis. The hysteresis angle varies during a sweep through the resonance conditions for a free radical. By recording this variation, a magnetization hysteresis (MH) spectrum results. In practice, a MH spectrum is computer calculated from two EPR spectra detected with a 90 degree difference in phase setting. There is no need for a careful null-phase calibration like that in traditional analysis of nonlinearities. The MH spectra calculated from second harmonic EPR spectra of spin labels were highly dependent on the rotational correlation time. The technique can therefore be used to study slow molecular motion. In the present work MH spectra and Hemminga and deJager's magnitude saturation transfer EPR spectra (Hemminga, M. A., and P. A. deJager, 1981, J. Magn. Reson., 43:324-327) have been analyzed to define parameters that can describe variations in the rotational correlation time. A novel modification of the sample holder and temperature regulation equipment is described. PMID:6309263

  11. Music-based magnetic resonance fingerprinting to improve patient comfort during MRI examinations.

    PubMed

    Ma, Dan; Pierre, Eric Y; Jiang, Yun; Schluchter, Mark D; Setsompop, Kawin; Gulani, Vikas; Griswold, Mark A

    2016-06-01

    Unpleasant acoustic noise is a drawback of almost every MRI scan. Instead of reducing acoustic noise to improve patient comfort, we propose a technique for mitigating the noise problem by producing musical sounds directly from the switching magnetic fields while simultaneously quantifying multiple important tissue properties. MP3 music files were converted to arbitrary encoding gradients, which were then used with varying flip angles and repetition times in a two- and three-dimensional magnetic resonance fingerprinting (MRF) examination. This new acquisition method, named MRF-Music, was used to quantify T1 , T2 , and proton density maps simultaneously while providing pleasing sounds to the patients. MRF-Music scans improved patient comfort significantly during MRI examinations. The T1 and T2 values measured from phantom are in good agreement with those from the standard spin echo measurements. T1 and T2 values from the brain scan are also close to previously reported values. MRF-Music sequence provides significant improvement in patient comfort compared with the MRF scan and other fast imaging techniques such as echo planar imaging and turbo spin echo scans. It is also a fast and accurate quantitative method that quantifies multiple relaxation parameters simultaneously. Magn Reson Med 75:2303-2314, 2016. © 2015 Wiley Periodicals, Inc. © 2015 Wiley Periodicals, Inc.

  12. On NUFFT-based gridding for non-Cartesian MRI

    NASA Astrophysics Data System (ADS)

    Fessler, Jeffrey A.

    2007-10-01

    For MRI with non-Cartesian sampling, the conventional approach to reconstructing images is to use the gridding method with a Kaiser-Bessel (KB) interpolation kernel. Recently, Sha et al. [L. Sha, H. Guo, A.W. Song, An improved gridding method for spiral MRI using nonuniform fast Fourier transform, J. Magn. Reson. 162(2) (2003) 250-258] proposed an alternative method based on a nonuniform FFT (NUFFT) with least-squares (LS) design of the interpolation coefficients. They described this LS_NUFFT method as shift variant and reported that it yielded smaller reconstruction approximation errors than the conventional shift-invariant KB approach. This paper analyzes the LS_NUFFT approach in detail. We show that when one accounts for a certain linear phase factor, the core of the LS_NUFFT interpolator is in fact real and shift invariant. Furthermore, we find that the KB approach yields smaller errors than the original LS_NUFFT approach. We show that optimizing certain scaling factors can lead to a somewhat improved LS_NUFFT approach, but the high computation cost seems to outweigh the modest reduction in reconstruction error. We conclude that the standard KB approach, with appropriate parameters as described in the literature, remains the practical method of choice for gridding reconstruction in MRI.

  13. Quantitative magnetic resonance imaging phantoms: A review and the need for a system phantom.

    PubMed

    Keenan, Kathryn E; Ainslie, Maureen; Barker, Alex J; Boss, Michael A; Cecil, Kim M; Charles, Cecil; Chenevert, Thomas L; Clarke, Larry; Evelhoch, Jeffrey L; Finn, Paul; Gembris, Daniel; Gunter, Jeffrey L; Hill, Derek L G; Jack, Clifford R; Jackson, Edward F; Liu, Guoying; Russek, Stephen E; Sharma, Samir D; Steckner, Michael; Stupic, Karl F; Trzasko, Joshua D; Yuan, Chun; Zheng, Jie

    2018-01-01

    The MRI community is using quantitative mapping techniques to complement qualitative imaging. For quantitative imaging to reach its full potential, it is necessary to analyze measurements across systems and longitudinally. Clinical use of quantitative imaging can be facilitated through adoption and use of a standard system phantom, a calibration/standard reference object, to assess the performance of an MRI machine. The International Society of Magnetic Resonance in Medicine AdHoc Committee on Standards for Quantitative Magnetic Resonance was established in February 2007 to facilitate the expansion of MRI as a mainstream modality for multi-institutional measurements, including, among other things, multicenter trials. The goal of the Standards for Quantitative Magnetic Resonance committee was to provide a framework to ensure that quantitative measures derived from MR data are comparable over time, between subjects, between sites, and between vendors. This paper, written by members of the Standards for Quantitative Magnetic Resonance committee, reviews standardization attempts and then details the need, requirements, and implementation plan for a standard system phantom for quantitative MRI. In addition, application-specific phantoms and implementation of quantitative MRI are reviewed. Magn Reson Med 79:48-61, 2018. © 2017 International Society for Magnetic Resonance in Medicine. © 2017 International Society for Magnetic Resonance in Medicine.

  14. Automated eye blink detection and correction method for clinical MR eye imaging.

    PubMed

    Wezel, Joep; Garpebring, Anders; Webb, Andrew G; van Osch, Matthias J P; Beenakker, Jan-Willem M

    2017-07-01

    To implement an on-line monitoring system to detect eye blinks during ocular MRI using field probes, and to reacquire corrupted k-space lines by means of an automatic feedback system integrated with the MR scanner. Six healthy subjects were scanned on a 7 Tesla MRI whole-body system using a custom-built receive coil. Subjects were asked to blink multiple times during the MR-scan. The local magnetic field changes were detected with an external fluorine-based field probe which was positioned close to the eye. The eye blink produces a field shift greater than a threshold level, this was communicated in real-time to the MR system which immediately reacquired the motion-corrupted k-space lines. The uncorrected images, using the original motion-corrupted data, showed severe artifacts, whereas the corrected images, using the reacquired data, provided an image quality similar to images acquired without blinks. Field probes can successfully detect eye blinks during MRI scans. By automatically reacquiring the eye blink-corrupted data, high quality MR-images of the eye can be acquired. Magn Reson Med 78:165-171, 2017. © 2016 International Society for Magnetic Resonance in Medicine. © 2016 International Society for Magnetic Resonance in Medicine.

  15. Renal MR angiography and perfusion in the pig using hyperpolarized water.

    PubMed

    Wigh Lipsø, Kasper; Hansen, Esben Søvsø Szocska; Tougaard, Rasmus Stilling; Laustsen, Christoffer; Ardenkjaer-Larsen, Jan Henrik

    2017-09-01

    To study hyperpolarized water as an angiography and perfusion tracer in a large animal model. Protons dissolved in deuterium oxide (D 2 O) were hyperpolarized in a SPINlab dissolution dynamic nuclear polarization (dDNP) polarizer and subsequently investigated in vivo in a pig model at 3 Tesla (T). Approximately 15 mL of hyperpolarized water was injected in the renal artery by hand over 4-5 s. A liquid state polarization of 5.3 ± 0.9% of 3.8 M protons in 15 mL of deuterium oxide was achieved with a T 1 of 24 ± 1 s. This allowed injection through an arterial catheter into the renal artery and subsequently high-contrast imaging of the entire kidney parenchyma over several seconds. The dynamic images allow quantification of tissue perfusion, with a mean cortical perfusion of 504 ± 123 mL/100 mL/min. Hyperpolarized water MR imaging was successfully demonstrated as a renal angiography and perfusion method. Quantitative perfusion maps of the kidney were obtained in agreement with literature and control experiments with gadolinium contrast. Magn Reson Med 78:1131-1135, 2017. © 2016 International Society for Magnetic Resonance in Medicine. © 2016 International Society for Magnetic Resonance in Medicine.

  16. Application of 3D-MR image registration to monitor diseases around the knee joint.

    PubMed

    Takao, Masaki; Sugano, Nobuhiko; Nishii, Takashi; Miki, Hidenobu; Koyama, Tsuyoshi; Masumoto, Jun; Sato, Yoshinobu; Tamura, Shinichi; Yoshikawa, Hideki

    2005-11-01

    To estimate the accuracy and consistency of a method using a voxel-based MR image registration algorithm for precise monitoring of knee joint diseases. Rigid body transformation was calculated using a normalized cross-correlation (NCC) algorithm involving simple manual segmentation of the bone region based on its anatomical features. The accuracy of registration was evaluated using four phantoms, followed by a consistency test using MR data from the 11 patients with knee joint disease. The registration accuracy in the phantom experiment was 0.49+/-0.19 mm (SD) for the femur and 0.56+/-0.21 mm (SD) for the tibia. The consistency value in the experiment using clinical data was 0.69+/-0.25 mm (SD) for the femur and 0.77+/-0.37 mm (SD) for the tibia. These values were all smaller than a voxel (1.25 x 1.25 x 1.5 mm). The present method based on an NCC algorithm can be used to register serial MR images of the knee joint with error on the order of a sub-voxel. This method would be useful for precisely assessing therapeutic response and monitoring knee joint diseases; normalized cross-correlation; accuracy. J. Magn. Reson. Imaging 2005. (c) 2005 Wiley-Liss, Inc.

  17. On the lorentzian versus Gaussian character of time-domain spin-echo signals from the brain as sampled by means of gradient-echoes: Implications for quantitative transverse relaxation studies.

    PubMed

    Mulkern, Robert V; Balasubramanian, Mukund; Mitsouras, Dimitrios

    2014-07-30

    To determine whether Lorentzian or Gaussian intra-voxel frequency distributions are better suited for modeling data acquired with gradient-echo sampling of single spin-echoes for the simultaneous characterization of irreversible and reversible relaxation rates. Clinical studies (e.g., of brain iron deposition) using such acquisition schemes have typically assumed Lorentzian distributions. Theoretical expressions of the time-domain spin-echo signal for intra-voxel Lorentzian and Gaussian distributions were used to fit data from a human brain scanned at both 1.5 Tesla (T) and 3T, resulting in maps of irreversible and reversible relaxation rates for each model. The relative merits of the Lorentzian versus Gaussian model were compared by means of quality of fit considerations. Lorentzian fits were equivalent to Gaussian fits primarily in regions of the brain where irreversible relaxation dominated. In the multiple brain regions where reversible relaxation effects become prominent, however, Gaussian fits were clearly superior. The widespread assumption that a Lorentzian distribution is suitable for quantitative transverse relaxation studies of the brain should be reconsidered, particularly at 3T and higher field strengths as reversible relaxation effects become more prominent. Gaussian distributions offer alternate fits of experimental data that should prove quite useful in general. Magn Reson Med, 2014. © 2014 Wiley Periodicals, Inc. © 2014 Wiley Periodicals, Inc.

  18. Eddy current compensated double diffusion encoded (DDE) MRI.

    PubMed

    Mueller, Lars; Wetscherek, Andreas; Kuder, Tristan Anselm; Laun, Frederik Bernd

    2017-01-01

    Eddy currents might lead to image distortions in diffusion-weighted echo planar imaging. A method is proposed to reduce their effects on double diffusion encoding (DDE) MRI experiments and the thereby derived microscopic fractional anisotropy (μFA). The twice-refocused spin echo scheme was adapted for DDE measurements. To assess the effect of individual diffusion encodings on the image distortions, measurements of a grid of plastic rods in water were performed. The effect of eddy current compensation on μFA measurements was evaluated in the brains of six healthy volunteers. The use of an eddy current compensation reduced the signal variation. As expected, the distortions caused by the second encoding were larger than those of the first encoding, entailing a stronger need to compensate for them. For an optimal result, however, both encodings had to be compensated. The artifact reduction strongly improved the measurement of the μFA in ventricles and gray matter by reducing the overestimation. An effect of the compensation on absolute μFA values in white matter was not observed. It is advisable to compensate both encodings in DDE measurements for eddy currents. Magn Reson Med 77:328-335, 2017. © 2015 Wiley Periodicals, Inc. © 2015 Wiley Periodicals, Inc.

  19. A geometrical shift results in erroneous appearance of low frequency tissue eddy current induced phase maps.

    PubMed

    Mandija, Stefano; van Lier, Astrid L H M W; Katscher, Ulrich; Petrov, Petar I; Neggers, Sebastian F W; Luijten, Peter R; van den Berg, Cornelis A T

    2016-09-01

    Knowledge on low frequency (LF) tissue conductivity is relevant for various biomedical purposes. To obtain this information, LF phase maps arising from time-varying imaging gradients have been demonstrated to create a LF conductivity contrast. Essential in this methodology is the subtraction of phase images acquired with opposite gradient polarities to separate LF and RF phase effects. Here we demonstrate how sensitive these subtractions are with respect to geometrical distortions. The effect of geometrical distortions on LF phase maps is mathematically defined. After quantifying typical geometrical distortions, their effects on LF phase maps are evaluated using conductive phantoms. For validation, electromagnetic simulations of LF phase maps were performed. Even sub-voxel distortions of 10% of the voxel size, measured for a typical LF MR sequence, cause leakage of RF phase into LF phase of several milli-radians, leading to a misleading pattern of LF phase maps. This leakage is mathematically confirmed, while simulations indicate that the expected LF phase should be in order of micro-radians. The conductivity scaling of LF phase maps is attributable to the RF phase leakage, thus dependent on the RF conductivity. In fact, simulations show that the LF phase is not measurable. Magn Reson Med 76:905-912, 2016. © 2015 Wiley Periodicals, Inc. © 2015 Wiley Periodicals, Inc.

  20. SAR and scan-time optimized 3D whole-brain double inversion recovery imaging at 7T.

    PubMed

    Pracht, Eberhard D; Feiweier, Thorsten; Ehses, Philipp; Brenner, Daniel; Roebroeck, Alard; Weber, Bernd; Stöcker, Tony

    2018-05-01

    The aim of this project was to implement an ultra-high field (UHF) optimized double inversion recovery (DIR) sequence for gray matter (GM) imaging, enabling whole brain coverage in short acquisition times ( ≈5 min, image resolution 1 mm 3 ). A 3D variable flip angle DIR turbo spin echo (TSE) sequence was optimized for UHF application. We implemented an improved, fast, and specific absorption rate (SAR) efficient TSE imaging module, utilizing improved reordering. The DIR preparation was tailored to UHF application. Additionally, fat artifacts were minimized by employing water excitation instead of fat saturation. GM images, covering the whole brain, were acquired in 7 min scan time at 1 mm isotropic resolution. SAR issues were overcome by using a dedicated flip angle calculation considering SAR and SNR efficiency. Furthermore, UHF related artifacts were minimized. The suggested sequence is suitable to generate GM images with whole-brain coverage at UHF. Due to the short total acquisition times and overall robustness, this approach can potentially enable DIR application in a routine setting and enhance lesion detection in neurological diseases. Magn Reson Med 79:2620-2628, 2018. © 2017 International Society for Magnetic Resonance in Medicine. © 2017 International Society for Magnetic Resonance in Medicine.

  1. General design approach and practical realization of decoupling matrices for parallel transmission coils.

    PubMed

    Mahmood, Zohaib; McDaniel, Patrick; Guérin, Bastien; Keil, Boris; Vester, Markus; Adalsteinsson, Elfar; Wald, Lawrence L; Daniel, Luca

    2016-07-01

    In a coupled parallel transmit (pTx) array, the power delivered to a channel is partially distributed to other channels because of coupling. This power is dissipated in circulators resulting in a significant reduction in power efficiency. In this study, a technique for designing robust decoupling matrices interfaced between the RF amplifiers and the coils is proposed. The decoupling matrices ensure that most forward power is delivered to the load without loss of encoding capabilities of the pTx array. The decoupling condition requires that the impedance matrix seen by the power amplifiers is a diagonal matrix whose entries match the characteristic impedance of the power amplifiers. In this work, the impedance matrix of the coupled coils is diagonalized by a successive multiplication by its eigenvectors. A general design procedure and software are developed to generate automatically the hardware that implements diagonalization using passive components. The general design method is demonstrated by decoupling two example parallel transmit arrays. Our decoupling matrices achieve better than -20 db decoupling in both cases. A robust framework for designing decoupling matrices for pTx arrays is presented and validated. The proposed decoupling strategy theoretically scales to any arbitrary number of channels. Magn Reson Med 76:329-339, 2016. © 2015 Wiley Periodicals, Inc. © 2015 Wiley Periodicals, Inc.

  2. Combined geometric and algebraic solutions for removal of bSSFP banding artifacts with performance comparisons.

    PubMed

    Hoff, Michael N; Andre, Jalal B; Xiang, Qing-San

    2017-02-01

    Balanced steady state free precession (bSSFP) imaging suffers from off-resonance artifacts such as signal modulation and banding. Solutions for removal of bSSFP off-resonance dependence are described and compared, and an optimal solution is proposed. An Algebraic Solution (AS) that complements a previously described Geometric Solution (GS) is derived from four phase-cycled bSSFP datasets. A composite Geometric-Algebraic Solution (GAS) is formed from a noise-variance-weighted average of the AS and GS images. Two simulations test the solutions over a range of parameters, and phantom and in vivo experiments are implemented. Image quality and performance of the GS, AS, and GAS are compared with the complex sum and a numerical parameter estimation algorithm. The parameter estimation algorithm, GS, AS, and GAS remove most banding and signal modulation in bSSFP imaging. The variable performance of the GS and AS on noisy data justifies generation of the GAS, which consistently provides the highest performance. The GAS is a robust technique for bSSFP signal demodulation that balances the regional efficacy of the GS and AS to remove banding, a feat not possible with prevalent techniques. Magn Reson Med 77:644-654, 2017. © 2016 International Society for Magnetic Resonance in Medicine. © 2016 International Society for Magnetic Resonance in Medicine.

  3. Review of the critical current densities and magnetic irreversibilities in high T_c superconductors

    NASA Astrophysics Data System (ADS)

    Senoussi, S.

    1992-07-01

    This review article is concerned with critical current density (J) and magnetic irreversibilities in high-T_c superconductors (HTSC). The apparent J derived from different experimental techniques (transport, hysteresis cycle, ac-susceptibility) are compared. The influence of time (relaxation effects) as well as the macroscopic size of the sample on the criteria defining J are discussed. The dependences of the critical current on grain boundaries (“weaks-links”), texturing and other physical and chemical defects are examined in detail. The role of self fields is clarified. The critical current is strongly influenced by the anisotropy of the layered structure practically whatever the experimental conditions. Intrinsic pinning is lowered by defects. Demagnetizing effects and surface pinnings are reviewed. The usual critical state and flux creep models are recalled emphasizing the physical aspects most specific to HTSC. A theoretical model which takes into account the equilibrium magnetization and sample granularity is developed. It reproduces most of the characteristic features of both the hysteresis cycle and ac-susceptibility. A number of new formulae are introduced. They generalize the Bean model and show how to correct for the dimensions of the grains (granular materials), the macroscopic radius of the sample, anisotropy and demagnetization effects in certain situations. Several limits beyond which the usual critical state breaks down are discussed: (1) the quasi elastic limit where the variable field is too weak to depin the vortices, (2) H≈ H_C1 so that the interaction between vortex lines is exponentially weak and (3) T and H close to the “irreversibility line” where the influence of viscous forces are strong. (4) Hgg H_C1 so that J is governed by collective pinning. Ce papier de revue est consacré aux courant critiques (J) et aux irréversibilités magnétiques dans les nouveaux matériaux supraconducteurs (HTSC). Nous y comparons les densités des

  4. Topical dura mater application of CFA induces enhanced expression of c-fos and glutamate in rat trigeminal nucleus caudalis: attenuated by KYNA derivate (SZR72).

    PubMed

    Lukács, M; Warfvinge, K; Tajti, J; Fülöp, F; Toldi, J; Vécsei, L; Edvinsson, L

    2017-12-01

    Migraine is a debilitating neurological disorder where trigeminovascular activation plays a key role. We have previously reported that local application of Complete Freund's Adjuvant (CFA) onto the dura mater caused activation in rat trigeminal ganglion (TG) which was abolished by a systemic administration of kynurenic acid (KYNA) derivate (SZR72). Here, we hypothesize that this activation may extend to the trigeminal complex in the brainstem and is attenuated by treatment with SZR72. Activation in the trigeminal nucleus caudalis (TNC) and the trigeminal tract (Sp5) was achieved by application of CFA onto the dural parietal surface. SZR72 was given intraperitoneally (i.p.), one dose prior CFA deposition and repeatedly daily for 7 days. Immunohistochemical studies were performed for mapping glutamate, c-fos, PACAP, substance P, IL-6, IL-1β and TNFα in the TNC/Sp5 and other regions of the brainstem and at the C 1 -C 2 regions of the spinal cord. We found that CFA increased c-fos and glutamate immunoreactivity in TNC and C 1 -C 2 neurons. This effect was mitigated by SZR72. PACAP positive fibers were detected in the fasciculus cuneatus and gracilis. Substance P, TNFα, IL-6 and IL-1β immunopositivity were detected in fibers of Sp5 and neither of these molecules showed any change in immunoreactivity following CFA administration. This is the first study demonstrating that dural application of CFA increases the expression of c-fos and glutamate in TNC neurons. Treatment with the KYNA analogue prevented this expression.

  5. What band rocks the MTB? (Invited)

    NASA Astrophysics Data System (ADS)

    Kind, J.; García-Rubio, I.; Gehring, A. U.

    2013-12-01

    generally leads to a better resolution of the chain configuration. Finally, for the investigation of geological samples, the application of S-band can be a powerful tool to complement the commonly used X-band FMR spectroscopy, i.e. multiple band rock the MTB. [1] Blakemore R.P., 1975, Magnetotactic bacteria, Science, 190, 377-379 [2] Mastogiacomo G., Fischer H., Garcia-Rubio I., and Gehring A. U., 2010, Ferromagnetic resonance spectroscopic response of magnetic chains in a biological matrix, J. Magn. Magn. Matter, 322, 661-663, doi: 10.1016/j.jmmm.2009.10.035 [3] Gehring A. U., Kind. J., Charilaou M., Garcia-Rubio I., 2011, S-band ferromagnetic resonance spectroscopy and the detection of magnetofossils, J. R. Soc. Interface, 10(80), doi: 10.1098/rsif.2012.0790 [4] Kind J., van Raden U., Garcia-Rubio I., and Gehring A. U., 2012, Rock magnetic techniques complemented by ferromagnetic resonance spectroscopy to analyse a sediment record, Geophys. J. Int., 191, 51-61, doi: 10.1111/j.1365-246X.2012.05620.x

  6. Corrigendum to "Multiple-quantum spin counting in magic-angle-spinning NMR via low-power symmetry-based dipolar recoupling" [J. Magn. Reson. 236 (2013) 31-40

    NASA Astrophysics Data System (ADS)

    Teymoori, Gholamhasan; Pahari, Bholanath; Viswanathan, Elumalai; Edén, Mattias

    2017-03-01

    The authors regret that an inappropriate NMR data processing, not known to all authors at the time of publication, was used to produce the multiple-quantum coherence (MQC) spin counting data presented in our article: this lead to artificially enhanced results, particularly concerning those obtained at long MQC excitation intervals (τexc). Here we reproduce Figs. 4-7 with correctly processed data.

  7. Comparative evaluation of guided tissue regeneration with use of collagen-based barrier freeze-dried dura mater allograft for mandibular class 2 furcation defects (a comparative controlled clinical study).

    PubMed

    Patel, Sandeep; Kubavat, Ajay; Ruparelia, Brijesh; Agarwal, Arvind; Panda, Anup

    2012-01-01

    The aim of periodontal surgery is complete regeneration. The present study was designed to evaluate and compare clinically soft tissue changes in form of probing pocket depth, gingival shrinkage, attachment level and hard tissue changes in form of horizontal and vertical bone level using resorbable membranes. Twelve subjects with bilateral class 2 furcation defects were selected. After initial phase one treatment, open debridement was performed in control site while freezedried dura mater allograft was used in experimental site. Soft and hard tissue parameters were registered intrasurgically. Nine months reentry ensured better understanding and evaluation of the final outcome of the study. Guided tissue regeneration is a predictable treatment modality for class 2 furcation defect. There was statistically significant reduction in pocket depth as compared to control (p < 0.01). There is statistically significant increase in periodontal attachment level within control and experimental sites showed better results (p < 0.01). For hard tissue parameter, significant defect fill resulted in experimental group, while in control group, less significant defect fill was found in horizontal direction and nonsignificant defect fill was found in vertical direction. The results showed statistically significant improvement in soft and hard tissue parameters and less gingival shrinkage in experimental sites compared to control site. The use of FDDMA in furcation defects helps us to achieve predictable results. This cross-linked collagen membrane has better handling properties and ease of procurement as well as economic viability making it a logical material to be used in regenerative surgeries.

  8. Osteogenic differentiation of dura mater stem cells cultured in vitro on three-dimensional porous scaffolds of poly(ε-caprolactone) fabricated via co-extrusion and gas foaming

    PubMed Central

    Aronin, C.E. Petrie; Cooper, J.A.; Sefcik, L.S.; Tholpady, S.S.; Ogle, R.C.; Botchwey, E.A.

    2008-01-01

    A novel scaffold fabrication method utilizing both polymer blend extrusion and gas foaming techniques to control pore size distribution is presented. Seventy five per cent of all pores produced using polymer blend extrusion alone were less than 50 μm. Introducing a gas technique provided better control of pore size distribution, expanding the range from 0-50 to 0-350 μm. Varying sintering time, annealing temperature and foaming pressure also helped reduced the percentage of pore sizes below 50 μm. Scaffolds chosen for in vitro cellular studies had a pore size distribution of 0-300 μm, average pore size 66 ± 17 μm, 0.54 ± 0.02% porosity and 98% interconnectivity, measured by micro computed tomography (microCT) analysis. The ability of the scaffolds to support osteogenic differentiation and cranial defect repair was evaluated by static and dynamic (0.035 ± 0.006 m s-1 terminal velocity) cultivation with dura mater stem cells (DSCs). In vitro studies showed minimal increases in proliferation over 28 days in culture in osteogenic media. Alkaline phosphatase expression remained constant throughout the study. Moderate increases in matrix deposition, as assessed by histochemical staining and microCT analysis, occurred at later time points, days 21 and 28. Although constructs cultured dynamically showed greater mineralization than static conditions, these trends were not significant. It remains unclear whether bioreactor culture of DSCs is advantageous for bone tissue engineering applications. However, these studies show that polycaprolactone (PCL) scaffolds alone, without the addition of other co-polymers or ceramics, support long-term attachment and mineralization of DSCs throughout the entire porous scaffold. PMID:18434267

  9. Pregnant women models analyzed for RF exposure and temperature increase in 3T RF shimmed birdcages.

    PubMed

    Murbach, Manuel; Neufeld, Esra; Samaras, Theodoros; Córcoles, Juan; Robb, Fraser J; Kainz, Wolfgang; Kuster, Niels

    2017-05-01

    MRI is increasingly used to scan pregnant patients. We investigated the effect of 3 Tesla (T) two-port radiofrequency (RF) shimming in anatomical pregnant women models. RF shimming improves B 1 + uniformity, but may at the same time significantly alter the induced current distribution and result in large changes in both the level and location of the absorbed RF energy. In this study, we evaluated the electrothermal exposure of pregnant women in the third, seventh, and ninth month of gestation at various imaging landmarks in RF body coils, including modes with RF shimming. Although RF shimmed configurations may lower the local RF exposure for the mother, they can increase the thermal load on the fetus. In worst-case configurations, whole-body exposure and local peak temperatures-up to 40.8°C-are equal in fetus and mother. Two-port RF shimming can significantly increase the fetal exposure in pregnant women, requiring further research to derive a very robust safety management. For the time being, restriction to the CP mode, which reduces fetal SAR exposure compared with linear-horizontal polarization modes, may be advisable. Results from this study do not support scanning pregnant patients above the normal operating mode. Magn Reson Med 77:2048-2056, 2017. © 2016 International Society for Magnetic Resonance in Medicine. © 2016 International Society for Magnetic Resonance in Medicine.

  10. Virtual population-based assessment of the impact of 3 Tesla radiofrequency shimming and thermoregulation on safety and B1 + uniformity.

    PubMed

    Murbach, Manuel; Neufeld, Esra; Cabot, Eugenia; Zastrow, Earl; Córcoles, Juan; Kainz, Wolfgang; Kuster, Niels

    2016-09-01

    To assess the effect of radiofrequency (RF) shimming of a 3 Tesla (T) two-port body coil on B1 + uniformity, the local specific absorption rate (SAR), and the local temperature increase as a function of the thermoregulatory response. RF shimming alters induced current distribution, which may result in large changes in the level and location of absorbed RF energy. We investigated this effect with six anatomical human models from the Virtual Population in 10 imaging landmarks and four RF coils. Three thermoregulation models were applied to estimate potential local temperature increases, including a newly proposed model for impaired thermoregulation. Two-port RF shimming, compared to circular polarization mode, can increase the B1 + uniformity on average by +32%. Worst-case SAR excitations increase the local RF power deposition on average by +39%. In the first level controlled operating mode, induced peak temperatures reach 42.5°C and 45.6°C in patients with normal and impaired thermoregulation, respectively. Image quality with 3T body coils can be significantly increased by RF shimming. Exposure in realistic scan scenarios within guideline limits can be considered safe for a broad patient population with normal thermoregulation. Patients with impaired thermoregulation should not be scanned outside of the normal operating mode. Magn Reson Med 76:986-997, 2016. © 2015 Wiley Periodicals, Inc. © 2015 Wiley Periodicals, Inc.

  11. 16-channel bow tie antenna transceiver array for cardiac MR at 7.0 tesla.

    PubMed

    Oezerdem, Celal; Winter, Lukas; Graessl, Andreas; Paul, Katharina; Els, Antje; Weinberger, Oliver; Rieger, Jan; Kuehne, Andre; Dieringer, Matthias; Hezel, Fabian; Voit, Dirk; Frahm, Jens; Niendorf, Thoralf

    2016-06-01

    To design, evaluate, and apply a bow tie antenna transceiver radiofrequency (RF) coil array tailored for cardiac MRI at 7.0 Tesla (T). The radiofrequency (RF) coil array comprises 16 building blocks each containing a bow tie shaped λ/2-dipole antenna. Numerical simulations were used for transmission field homogenization and RF safety validation. RF characteristics were examined in a phantom study. The array's suitability for high spatial resolution two-dimensional (2D) CINE imaging and for real time imaging of the heart was examined in a volunteer study. The arrays transmission fields and RF characteristics are suitable for cardiac MRI at 7.0T. The coil performance afforded a spatial resolution as good as (0.8 × 0.8 × 2.5) mm(3) for segmented 2D CINE MRI at 7.0T which is by a factor of 12 superior versus standardized protocols used in clinical practice at 1.5T. The proposed transceiver array supports 1D acceleration factors of up to R = 6 without impairing image quality significantly. The 16-channel bow tie antenna transceiver array supports accelerated and high spatial resolution cardiac MRI. The array is compatible with multichannel transmission and provides a technological basis for future clinical assessment of parallel transmission techniques at 7.0 Tesla. Magn Reson Med 75:2553-2565, 2016. © 2015 Wiley Periodicals, Inc. © 2015 Wiley Periodicals, Inc.

  12. Dielectric waveguides for ultrahigh field magnetic resonance imaging.

    PubMed

    Bluemink, Johanna J; Raaijmakers, Alexander J E; Koning, Wouter; Andreychenko, Anna; Rivera, Debra S; Luijten, Peter R; Klomp, Dennis W J; van den Berg, Cornelis A T

    2016-10-01

    The design of RF coils for MRI transmit becomes increasingly challenging at high frequencies required for MRI at 7T and above. Our goal is to show a proof of principle of a new type of transmit coil for higher field strengths. We demonstrate an alternative transmit coil design based on dielectric waveguide principles which transfers energy via evanescent wave coupling. The operating principles and conditions are explored by simulations. The waveguide is applied for in vivo imaging at 7T. The waveguide can be an efficient transmit coil when four conditions are fulfilled: (1) the waveguide should be operated just above the cutoff frequency of the lowest order transverse electric mode, (2) the waveguide should not operate at a frequency where the wavelength fits an integer number of times in the waveguide length and standing wave patterns become very prominent, (3) for homogeneous excitation, the waveguide should be bent around the object, and (4) there should be an air gap between the waveguide and the object. By choosing the dielectric and the dimensions adequately, the dielectric waveguide couples the magnetic field efficiently into the body. The waveguide can be redesigned for higher frequencies by simple adaptations and may be a promising transmit alternative. Magn Reson Med 76:1314-1324, 2016. © 2015 Wiley Periodicals, Inc. © 2015 Wiley Periodicals, Inc.

  13. An automated tool for cortical feature analysis: Application to differences on 7 Tesla T2* -weighted images between young and older healthy subjects.

    PubMed

    Doan, Nhat Trung; van Rooden, Sanneke; Versluis, Maarten J; Buijs, Mathijs; Webb, Andrew G; van der Grond, Jeroen; van Buchem, Mark A; Reiber, Johan H C; Milles, Julien

    2015-07-01

    High field T 2 * -weighted MR images of the cerebral cortex are increasingly used to study tissue susceptibility changes related to aging or pathologies. This paper presents a novel automated method for the computation of quantitative cortical measures and group-wise comparison using 7 Tesla T 2 * -weighted magnitude and phase images. The cerebral cortex was segmented using a combination of T 2 * -weighted magnitude and phase information and subsequently was parcellated based on an anatomical atlas. Local gray matter (GM)/white matter (WM) contrast and cortical profiles, which depict the magnitude or phase variation across the cortex, were computed from the magnitude and phase images in each parcellated region and further used for group-wise comparison. Differences in local GM/WM contrast were assessed using linear regression analysis. Regional cortical profiles were compared both globally and locally using permutation testing. The method was applied to compare a group of 10 young volunteers with a group of 15 older subjects. Using local GM/WM contrast, significant differences were revealed in at least 13 of 17 studied regions. Highly significant differences between cortical profiles were shown in all regions. The proposed method can be a useful tool for studying cortical changes in normal aging and potentially in neurodegenerative diseases. Magn Reson Med 74:240-248, 2015. © 2014 Wiley Periodicals, Inc. © 2014 Wiley Periodicals, Inc.

  14. Improved magnetic resonance fingerprinting reconstruction with low-rank and subspace modeling.

    PubMed

    Zhao, Bo; Setsompop, Kawin; Adalsteinsson, Elfar; Gagoski, Borjan; Ye, Huihui; Ma, Dan; Jiang, Yun; Ellen Grant, P; Griswold, Mark A; Wald, Lawrence L

    2018-02-01

    This article introduces a constrained imaging method based on low-rank and subspace modeling to improve the accuracy and speed of MR fingerprinting (MRF). A new model-based imaging method is developed for MRF to reconstruct high-quality time-series images and accurate tissue parameter maps (e.g., T 1 , T 2 , and spin density maps). Specifically, the proposed method exploits low-rank approximations of MRF time-series images, and further enforces temporal subspace constraints to capture magnetization dynamics. This allows the time-series image reconstruction problem to be formulated as a simple linear least-squares problem, which enables efficient computation. After image reconstruction, tissue parameter maps are estimated via dictionary-based pattern matching, as in the conventional approach. The effectiveness of the proposed method was evaluated with in vivo experiments. Compared with the conventional MRF reconstruction, the proposed method reconstructs time-series images with significantly reduced aliasing artifacts and noise contamination. Although the conventional approach exhibits some robustness to these corruptions, the improved time-series image reconstruction in turn provides more accurate tissue parameter maps. The improvement is pronounced especially when the acquisition time becomes short. The proposed method significantly improves the accuracy of MRF, and also reduces data acquisition time. Magn Reson Med 79:933-942, 2018. © 2017 International Society for Magnetic Resonance in Medicine. © 2017 International Society for Magnetic Resonance in Medicine.

  15. Improved olefinic fat suppression in skeletal muscle DTI using a magnitude-based dixon method.

    PubMed

    Burakiewicz, Jedrzej; Hooijmans, Melissa T; Webb, Andrew G; Verschuuren, Jan J G M; Niks, Erik H; Kan, Hermien E

    2018-01-01

    To develop a method of suppressing the multi-resonance fat signal in diffusion-weighted imaging of skeletal muscle. This is particularly important when imaging patients with muscular dystrophies, a group of diseases which cause gradual replacement of muscle tissue by fat. The signal from the olefinic fat peak at 5.3 ppm can significantly confound diffusion-tensor imaging measurements. Dixon olefinic fat suppression (DOFS), a magnitude-based chemical-shift-based method of suppressing the olefinic peak, is proposed. It is verified in vivo by performing diffusion tensor imaging (DTI)-based quantification in the lower leg of seven healthy volunteers, and compared to two previously described fat-suppression techniques in regions with and without fat contamination. In the region without fat contamination, DOFS produces similar results to existing techniques, whereas in muscle contaminated by subcutaneous fat signal moved due to the chemical shift artefact, it consistently showed significantly higher (P = 0.018) mean diffusivity (MD). Because fat presence lowers MD, this suggests improved fat suppression. DOFS offers superior fat suppression and enhances quantitative measurements in the muscle in the presence of fat. DOFS is an alternative to spectral olefinic fat suppression. Magn Reson Med 79:152-159, 2018. © 2017 International Society for Magnetic Resonance in Medicine. © 2017 International Society for Magnetic Resonance in Medicine.

  16. Assessing the effects of subject motion on T2 relaxation under spin tagging (TRUST) cerebral oxygenation measurements using volume navigators.

    PubMed

    Stout, Jeffrey N; Tisdall, M Dylan; McDaniel, Patrick; Gagoski, Borjan; Bolar, Divya S; Grant, Patricia Ellen; Adalsteinsson, Elfar

    2017-12-01

    Subject motion may cause errors in estimates of blood T 2 when using the T 2 -relaxation under spin tagging (TRUST) technique on noncompliant subjects like neonates. By incorporating 3D volume navigators (vNavs) into the TRUST pulse sequence, independent measurements of motion during scanning permit evaluation of these errors. The effects of integrated vNavs on TRUST-based T 2 estimates were evaluated using simulations and in vivo subject data. Two subjects were scanned with the TRUST+vNav sequence during prescribed movements. Mean motion scores were derived from vNavs and TRUST images, along with a metric of exponential fit quality. Regression analysis was performed between T 2 estimates and mean motion scores. Also, motion scores were determined from independent neonatal scans. vNavs negligibly affected venous blood T 2 estimates and better detected subject motion than fit quality metrics. Regression analysis showed that T 2 is biased upward by 4.1 ms per 1 mm of mean motion score. During neonatal scans, mean motion scores of 0.6 to 2.0 mm were detected. Motion during TRUST causes an overestimate of T 2 , which suggests a cautious approach when comparing TRUST-based cerebral oxygenation measurements of noncompliant subjects. Magn Reson Med 78:2283-2289, 2017. © 2017 International Society for Magnetic Resonance in Medicine. © 2017 International Society for Magnetic Resonance in Medicine.

  17. Multicontrast reconstruction using compressed sensing with low rank and spatially varying edge-preserving constraints for high-resolution MR characterization of myocardial infarction.

    PubMed

    Zhang, Li; Athavale, Prashant; Pop, Mihaela; Wright, Graham A

    2017-08-01

    To enable robust reconstruction for highly accelerated three-dimensional multicontrast late enhancement imaging to provide improved MR characterization of myocardial infarction with isotropic high spatial resolution. A new method using compressed sensing with low rank and spatially varying edge-preserving constraints (CS-LASER) is proposed to improve the reconstruction of fine image details from highly undersampled data. CS-LASER leverages the low rank feature of the multicontrast volume series in MR relaxation and integrates spatially varying edge preservation into the explicit low rank constrained compressed sensing framework using weighted total variation. With an orthogonal temporal basis pre-estimated, a multiscale iterative reconstruction framework is proposed to enable the practice of CS-LASER with spatially varying weights of appropriate accuracy. In in vivo pig studies with both retrospective and prospective undersamplings, CS-LASER preserved fine image details better and presented tissue characteristics with a higher degree of consistency with histopathology, particularly in the peri-infarct region, than an alternative technique for different acceleration rates. An isotropic resolution of 1.5 mm was achieved in vivo within a single breath-hold using the proposed techniques. Accelerated three-dimensional multicontrast late enhancement with CS-LASER can achieve improved MR characterization of myocardial infarction with high spatial resolution. Magn Reson Med 78:598-610, 2017. © 2016 International Society for Magnetic Resonance in Medicine. © 2016 International Society for Magnetic Resonance in Medicine.

  18. Sensitivity Enhancement of an Inductively Coupled Local Detector Using a HEMT-Based Current Amplifier.

    PubMed

    Qian, Chunqi; Duan, Qi; Dodd, Steve; Koretsky, Alan; Murphy-Boesch, Joe

    2016-06-01

    To improve the signal transmission efficiency and sensitivity of a local detection coil that is weakly inductively coupled to a larger receive coil. The resonant detection coil is connected in parallel with the gate of a high electron mobility transistor (HEMT) transistor without impedance matching. When the drain of the transistor is capacitively shunted to ground, current amplification occurs in the resonator by feedback that transforms a capacitive impedance on the transistor's source to a negative resistance on its gate. High resolution images were obtained from a mouse brain using a small, 11 mm diameter surface coil that was inductively coupled to a commercial, phased array chest coil. Although the power consumption of the amplifier was only 88 μW, 14 dB gain was obtained with excellent noise performance. An integrated current amplifier based on a HEMT can enhance the sensitivity of inductively coupled local detectors when weakly coupled. This amplifier enables efficient signal transmission between customized user coils and commercial clinical coils, without the need for a specialized signal interface. Magn Reson Med 75:2573-2578, 2016. Published 2015. This article is a U.S. Government work and is in the public domain in the USA. Published 2015 This article is a U.S. Government work and is in the public domain in the USA.

  19. Molecular, dynamic, and structural origin of inhomogeneous magnetization transfer in lipid membranes.

    PubMed

    Swanson, Scott D; Malyarenko, Dariya I; Fabiilli, Mario L; Welsh, Robert C; Nielsen, Jon-Fredrik; Srinivasan, Ashok

    2017-03-01

    To elucidate the dynamic, structural, and molecular properties that create inhomogeneous magnetization transfer (ihMT) contrast. Amphiphilic lipids, lamellar phospholipids with cholesterol, and bovine spinal cord (BSC) specimens were examined along with nonlipid systems. Magnetization transfer (MT), enhanced MT (eMT, obtained with double-sided radiofrequency saturation), ihMT (MT - eMT), and dipolar relaxation, T 1D , were measured at 2.0 and 11.7 T. The amplitude of ihMT ratio (ihMTR) is positively correlated with T 1D values. Both ihMTR and T 1D increase with increasing temperature in BSC white matter and in phospholipids and decrease with temperature in other lipids. Changes in ihMTR with temperature arise primarily from alterations in MT rather than eMT. Spectral width of MT, eMT, and ihMT increases with increasing carbon chain length. Concerted motions of phospholipids in white matter decrease proton spin diffusion leading to increased proton T 1D times and increased ihMT amplitudes, consistent with decoupling of Zeeman and dipolar spin reservoirs. Molecular specificity and dynamic sensitivity of ihMT contrast make it a suitable candidate for probing myelin membrane disorders. Magn Reson Med 77:1318-1328, 2017. © 2016 International Society for Magnetic Resonance in Medicine. © 2016 International Society for Magnetic Resonance in Medicine.

  20. Simultaneous orthogonal plane imaging.

    PubMed

    Mickevicius, Nikolai J; Paulson, Eric S

    2017-11-01

    Intrafraction motion can result in a smearing of planned external beam radiation therapy dose distributions, resulting in an uncertainty in dose actually deposited in tissue. The purpose of this paper is to present a pulse sequence that is capable of imaging a moving target at a high frame rate in two orthogonal planes simultaneously for MR-guided radiotherapy. By balancing the zero gradient moment on all axes, slices in two orthogonal planes may be spatially encoded simultaneously. The orthogonal slice groups may be acquired with equal or nonequal echo times. A Cartesian spoiled gradient echo simultaneous orthogonal plane imaging (SOPI) sequence was tested in phantom and in vivo. Multiplexed SOPI acquisitions were performed in which two parallel slices were imaged along two orthogonal axes simultaneously. An autocalibrating phase-constrained 2D-SENSE-GRAPPA (generalized autocalibrating partially parallel acquisition) algorithm was implemented to reconstruct the multiplexed data. SOPI images without intraslice motion artifacts were reconstructed at a maximum frame rate of 8.16 Hz. The 2D-SENSE-GRAPPA reconstruction separated the parallel slices aliased along each orthogonal axis. The high spatiotemporal resolution provided by SOPI has the potential to be beneficial for intrafraction motion management during MR-guided radiation therapy or other MRI-guided interventions. Magn Reson Med 78:1700-1710, 2017. © 2016 International Society for Magnetic Resonance in Medicine. © 2016 International Society for Magnetic Resonance in Medicine.

  1. Perturbation of longitudinal relaxation rate in rotating frame (PLRF) analysis for quantification of chemical exchange saturation transfer signal in a transient state.

    PubMed

    Wang, Yi; Zhang, Yaoyu; Zhao, Xuna; Wu, Bing; Gao, Jia-Hong

    2017-11-01

    To develop a novel analytical method for quantification of chemical exchange saturation transfer (CEST) in the transient state. The proposed method aims to reduce the effects of non-chemical-exchange (non-CE) parameters on the CEST signal, emphasizing the effect of chemical exchange. The difference in the longitudinal relaxation rate in the rotating frame ( ΔR1ρ) was calculated based on perturbation of the Z-value by R1ρ, and a saturation-pulse-amplitude-compensated exchange-dependent relaxation rate (SPACER) was determined with a high-exchange-rate approximation. In both phantom and human subject experiments, MTRasym (representative of the traditional CEST index), ΔR1ρ, and SPACER were measured, evaluated, and compared by altering the non-CE parameters in a transient-state continuous-wave CEST sequence. In line with the theoretical expectation, our experimental data demonstrate that the effects of the non-CE parameters can be more effectively reduced using the proposed indices (  ΔR1ρ and SPACER) than using the traditional CEST index ( MTRasym). The proposed method allows for the chemical exchange weight to be better emphasized in the transient-state CEST signal, which is beneficial, in practice, for quantifying the CEST signal. Magn Reson Med 78:1711-1723, 2017. © 2016 International Society for Magnetic Resonance in Medicine. © 2016 International Society for Magnetic Resonance in Medicine.

  2. Extended Monopole antenna Array with individual Shield (EMAS) coil: An improved monopole antenna design for brain imaging at 7 tesla MRI.

    PubMed

    Woo, Myung-Kyun; Hong, Suk-Min; Lee, Jongho; Kang, Chang-Ki; Park, Sung-Yeon; Son, Young-Don; Kim, Young-Bo; Cho, Zang-Hee

    2016-06-01

    To propose a new Extended Monopole antenna Array with individual Shields (EMAS) coil that improves the B1 field coverage and uniformity along the z-direction. To increase the spatial coverage of Monopole antenna Array (MA) coil, each monopole antenna was shielded and extended in length. Performance of this new coil, which is referred to as EMAS coil, was compared with the original MA coil and an Extended Monopole antenna Array coil with no shield (EMA). For comparison, flip angle, signal-to-noise ratio (SNR), and receive sensitivity maps were measured at multiple regions of interest (ROIs) in the brain. The EMAS coil demonstrated substantially larger flip angle and receive sensitivity than the MA and EMA coils in the inferior aspect of the brain. In the brainstem ROI, for example, the flip angle in the EMAS coil was increased by 45.5% (or 60.0%) and the receive sensitivity was increased by 26.9% (or 14.9%), resulting in an SNR gain of 84.8% (or 76.3%) when compared with the MA coil (or EMA). The EMAS coil provided 25.7% (or 24.4%) more uniform B1+ field distribution compared with the MA (or EMA) coil in sagittal. The EMAS coil successfully extended the imaging volume in lower part of the brain. Magn Reson Med 75:2566-2572, 2016. © 2015 Wiley Periodicals, Inc. © 2015 Wiley Periodicals, Inc.

  3. Plants as a source of butyrylcholinesterase variants designed for enhanced cocaine hydrolase activity.

    PubMed

    Larrimore, Katherine E; Barcus, Matthew; Kannan, Latha; Gao, Yang; Zhan, Chang-Guo; Brimijoin, Stephen; Mor, Tsafrir

    2013-03-25

    Cocaine addiction affects millions of people with disastrous personal and social consequences. Cocaine is one of the most reinforcing of all drugs of abuse, and even those who undergo rehabilitation and experience long periods of abstinence have more than 80% chance of relapse. Yet there is no FDA-approved treatment to decrease the likelihood of relapse in rehabilitated addicts. Recent studies, however, have demonstrated a promising potential treatment option with the help of the serum enzyme butyrylcholinesterase (BChE), which is capable of breaking down naturally occurring (-)-cocaine before the drug can influence the reward centers of the brain or affect other areas of the body. This activity of wild-type (WT) BChE, however, is relatively low. This prompted the design of variants of BChE which exhibit significantly improved catalytic activity against (-)-cocaine. Plants are a promising means to produce large amounts of these cocaine hydrolase variants of BChE, cheaply, safely with no concerns regarding human pathogens and functionally equivalent to enzymes derived from other sources. Here, in expressing cocaine-hydrolyzing mutants of BChE in Nicotiana benthamiana using the MagnICON virus-assisted transient expression system, and in reporting their initial biochemical analysis, we provide proof-of-principle that plants can express engineered BChE proteins with desired properties. Copyright © 2012 Elsevier Ireland Ltd. All rights reserved.

  4. La neurobrucellose: une cause curable de surdité neurosensorielle à ne pas méconnaitre

    PubMed Central

    Malhi, Alae Bezzari; Ridal, Mohamed; Bouchal, Siham; Belahsen, Mohammed Faouzi; El Alami, Mohamed-Nourdine

    2015-01-01

    La brucellose est une zoonose ubiquitaire touchant en particulier les pays méditerranéens et le Moyen-Orient. Les manifestations neurologiques sont assez diverses. Nous rapportons l'observation d'un patient âgé de 45 ans, agriculteur, ayant consulté pour une surdité profonde bilatérale depuis 2 mois associée à des céphalées, des épisodes d'hémiparésie à bascule, de trouble de langage, spontanément résolutifs en quelques minutes et des sensations vertigineuses intermittentes depuis 09 mois. Les résultats de la ponction lombaire, de l'imagerie par résonnance magnétique et surtout la sérologie ont permis de conclure à une neurobrucellose. L’évolution sous bi-antibiothérapie a été favorable, avec régression des signes neurologiques, normalisation du LCR et amélioration de la surdité. La neurobrucellose est une affection grave dont le pronostic dépend de la précocité du diagnostic et du traitement. Nous pensons qu'un tableau clinique associant une surdité neurosensorielle et une symptomatologie neurologique progressive doit évoquer en premier une neurobrucellose, d'autant plus que le patient est à risque et dans les pays où cette maladie est endémique. PMID:26889303

  5. Improved parallel image reconstruction using feature refinement.

    PubMed

    Cheng, Jing; Jia, Sen; Ying, Leslie; Liu, Yuanyuan; Wang, Shanshan; Zhu, Yanjie; Li, Ye; Zou, Chao; Liu, Xin; Liang, Dong

    2018-07-01

    The aim of this study was to develop a novel feature refinement MR reconstruction method from highly undersampled multichannel acquisitions for improving the image quality and preserve more detail information. The feature refinement technique, which uses a feature descriptor to pick up useful features from residual image discarded by sparsity constrains, is applied to preserve the details of the image in compressed sensing and parallel imaging in MRI (CS-pMRI). The texture descriptor and structure descriptor recognizing different types of features are required for forming the feature descriptor. Feasibility of the feature refinement was validated using three different multicoil reconstruction methods on in vivo data. Experimental results show that reconstruction methods with feature refinement improve the quality of reconstructed image and restore the image details more accurately than the original methods, which is also verified by the lower values of the root mean square error and high frequency error norm. A simple and effective way to preserve more useful detailed information in CS-pMRI is proposed. This technique can effectively improve the reconstruction quality and has superior performance in terms of detail preservation compared with the original version without feature refinement. Magn Reson Med 80:211-223, 2018. © 2017 International Society for Magnetic Resonance in Medicine. © 2017 International Society for Magnetic Resonance in Medicine.

  6. Fully phase-encoded MRI near metallic implants using ultrashort echo times and broadband excitation.

    PubMed

    Wiens, Curtis N; Artz, Nathan S; Jang, Hyungseok; McMillan, Alan B; Koch, Kevin M; Reeder, Scott B

    2018-04-01

    To develop a fully phase-encoded MRI method for distortion-free imaging near metallic implants, in clinically feasible acquisition times. An accelerated 3D fully phase-encoded acquisition with broadband excitation and ultrashort echo times is presented, which uses a broadband radiofrequency pulse to excite the entire off-resonance induced by the metallic implant. Furthermore, fully phase-encoded imaging is used to prevent distortions caused by frequency encoding, and to obtain ultrashort echo times for rapidly decaying signal. Phantom and in vivo acquisitions were used to describe the relationship among excitation bandwidth, signal loss near metallic implants, and T 1 weighting. Shorter radiofrequency pulses captured signal closer to the implant by improving spectral coverage and allowing shorter echo times, whereas longer pulses improved T 1 weighting through larger maximum attainable flip angles. Comparisons of fully phase-encoded acquisition with broadband excitation and ultrashort echo times to T 1 -weighted multi-acquisition with variable resonance image combination selective were performed in phantoms and subjects with metallic knee and hip prostheses. These acquisitions had similar contrast and acquisition efficiency. Accelerated fully phase-encoded acquisitions with ultrashort echo times and broadband excitation can generate distortion free images near metallic implants in clinically feasible acquisition times. Magn Reson Med 79:2156-2163, 2018. © 2017 International Society for Magnetic Resonance in Medicine. © 2017 International Society for Magnetic Resonance in Medicine.

  7. Fully Phase-Encoded MRI Near Metallic Implants Using Ultrashort Echo Times and Broadband Excitation

    PubMed Central

    Wiens, Curtis N.; Artz, Nathan S.; Jang, Hyungseok; McMillan, Alan B.; Koch, Kevin M.; Reeder, Scott B.

    2017-01-01

    Purpose To develop a fully phase-encoded MRI method for distortion-free imaging near metallic implants, in clinically feasible acquisition times. Theory and Methods An accelerated 3D fully phase-encoded acquisition with broadband excitation and ultrashort echo times is presented, which uses a broadband radiofrequency pulse to excite the entire off-resonance induced by the metallic implant. Furthermore, fully phase-encoded imaging is used to prevent distortions caused by frequency encoding, and to obtain ultrashort echo times for rapidly decaying signal. Results Phantom and in vivo acquisitions were used to describe the relationship among excitation bandwidth, signal loss near metallic implants, and T1 weighting. Shorter radiofrequency pulses captured signal closer to the implant by improving spectral coverage and allowing shorter echo times, whereas longer pulses improved T1 weighting through larger maximum attainable flip angles. Comparisons of fully phase-encoded acquisition with broadband excitation and ultrashort echo times to T1-weighted multi-acquisition with variable resonance image combination selective were performed in phantoms and subjects with metallic knee and hip prostheses. These acquisitions had similar contrast and acquisition efficiency. Conclusions Accelerated fully phase-encoded acquisitions with ultrashort echo times and broadband excitation can generate distortion free images near metallic implants in clinically feasible acquisition times. Magn Reson Med 000:000–000, 2017. PMID:28833407

  8. The viscosity and temperature dependence of 1H T1-NMRD of the Gd(H 2O) 83+ complex

    NASA Astrophysics Data System (ADS)

    Zhou, Xiangzhi; Westlund, Per-Olof

    2005-11-01

    Water proton T1-NMRD profiles of the Gd(H 2O) 83+ complex have been recorded at three temperatures and at four concentrations of glycerol. The analysis is performed using both the generalized Solomon-Bloembergen-Morgan (GSBM) theory [J. Magn. Reson. 167(2004), 147-160], and the stochastic Liouville approach (SLA). The GSBM approach uses a two processes dynamic model of the zero-field splitting (ZFS) correlation function whereas SLA uses a single process model. Both models reproduce the proton T1-NMRD profiles well. However, the model parameters extracted from the two analyses, yield different ESR X-band spectra which moreover do not reproduce the experimental ESR spectra. It is shown that the analyses of the proton T1-NMRD profiles recorded for a solution Gd(H 2O) 83+ ions are relatively insensitive to the slow modulation part of dynamic model of the ZFS interaction correlation function. The description of the electron spin system results in a very small static ZFS, while recent ESR lineshape analysis indicates that the contribution from the static ZFS is important. Analysis of proton T1-NMRD profiles of Gd(H 2O) 83+ complex do result in a description of the electron spin system but these microscopic parameters are uncertain unless they also are tested in a ESR-lineshape analysis.

  9. Water and fat separation in real-time MRI of joint movement with phase-sensitive bSSFP.

    PubMed

    Mazzoli, Valentina; Nederveen, Aart J; Oudeman, Jos; Sprengers, Andre; Nicolay, Klaas; Strijkers, Gustav J; Verdonschot, Nico

    2017-07-01

    To introduce a method for obtaining fat-suppressed images in real-time MRI of moving joints at 3 Tesla (T) using a bSSFP sequence with phase detection to enhance visualization of soft tissue structures during motion. The wrist and knee of nine volunteers were imaged with a real-time bSSFP sequence while performing dynamic tasks. For appropriate choice of sequence timing parameters, water and fat pixels showed an out-of-phase behavior, which was exploited to reconstruct water and fat images. Additionally, a 2-point Dixon sequence was used for dynamic imaging of the joints, and resulting water and fat images were compared with our proposed method. The joints could be visualized with good water-fat separation and signal-to-noise ratio (SNR), while maintaining a relatively high temporal resolution (5 fps in knee imaging and 10 fps in wrist imaging). The proposed method produced images of moving joints with higher SNR and higher image quality when compared with the Dixon method. Water-fat separation is feasible in real-time MRI of moving knee and wrist at 3 T. PS-bSSFP offers movies with higher SNR and higher diagnostic quality when compared with Dixon scans. Magn Reson Med 78:58-68, 2017. © 2016 International Society for Magnetic Resonance in Medicine. © 2016 International Society for Magnetic Resonance in Medicine.

  10. Joint Spatial-Spectral Reconstruction and k-t Spirals for Accelerated 2D Spatial/1D Spectral Imaging of 13C Dynamics

    PubMed Central

    Gordon, Jeremy W.; Niles, David J.; Fain, Sean B.; Johnson, Kevin M.

    2014-01-01

    Purpose To develop a novel imaging technique to reduce the number of excitations and required scan time for hyperpolarized 13C imaging. Methods A least-squares based optimization and reconstruction is developed to simultaneously solve for both spatial and spectral encoding. By jointly solving both domains, spectral imaging can potentially be performed with a spatially oversampled single echo spiral acquisition. Digital simulations, phantom experiments, and initial in vivo hyperpolarized [1-13C]pyruvate experiments were performed to assess the performance of the algorithm as compared to a multi-echo approach. Results Simulations and phantom data indicate that accurate single echo imaging is possible when coupled with oversampling factors greater than six (corresponding to a worst case of pyruvate to metabolite ratio < 9%), even in situations of substantial T2* decay and B0 heterogeneity. With lower oversampling rates, two echoes are required for similar accuracy. These results were confirmed with in vivo data experiments, showing accurate single echo spectral imaging with an oversampling factor of 7 and two echo imaging with an oversampling factor of 4. Conclusion The proposed k-t approach increases data acquisition efficiency by reducing the number of echoes required to generate spectroscopic images, thereby allowing accelerated acquisition speed, preserved polarization, and/or improved temporal or spatial resolution. Magn Reson Med PMID:23716402

  11. Subject-level reliability analysis of fast fMRI with application to epilepsy.

    PubMed

    Hao, Yongfu; Khoo, Hui Ming; von Ellenrieder, Nicolas; Gotman, Jean

    2017-07-01

    Recent studies have applied the new magnetic resonance encephalography (MREG) sequence to the study of interictal epileptic discharges (IEDs) in the electroencephalogram (EEG) of epileptic patients. However, there are no criteria to quantitatively evaluate different processing methods, to properly use the new sequence. We evaluated different processing steps of this new sequence under the common generalized linear model (GLM) framework by assessing the reliability of results. A bootstrap sampling technique was first used to generate multiple replicated data sets; a GLM with different processing steps was then applied to obtain activation maps, and the reliability of these maps was assessed. We applied our analysis in an event-related GLM related to IEDs. A higher reliability was achieved by using a GLM with head motion confound regressor with 24 components rather than the usual 6, with an autoregressive model of order 5 and with a canonical hemodynamic response function (HRF) rather than variable latency or patient-specific HRFs. Comparison of activation with IED field also favored the canonical HRF, consistent with the reliability analysis. The reliability analysis helps to optimize the processing methods for this fast fMRI sequence, in a context in which we do not know the ground truth of activation areas. Magn Reson Med 78:370-382, 2017. © 2016 International Society for Magnetic Resonance in Medicine. © 2016 International Society for Magnetic Resonance in Medicine.

  12. Vascular input function correction of inflow enhancement for improved pharmacokinetic modeling of liver DCE-MRI.

    PubMed

    Ning, Jia; Schubert, Tilman; Johnson, Kevin M; Roldán-Alzate, Alejandro; Chen, Huijun; Yuan, Chun; Reeder, Scott B

    2018-06-01

    To propose a simple method to correct vascular input function (VIF) due to inflow effects and to test whether the proposed method can provide more accurate VIFs for improved pharmacokinetic modeling. A spoiled gradient echo sequence-based inflow quantification and contrast agent concentration correction method was proposed. Simulations were conducted to illustrate improvement in the accuracy of VIF estimation and pharmacokinetic fitting. Animal studies with dynamic contrast-enhanced MR scans were conducted before, 1 week after, and 2 weeks after portal vein embolization (PVE) was performed in the left portal circulation of pigs. The proposed method was applied to correct the VIFs for model fitting. Pharmacokinetic parameters fitted using corrected and uncorrected VIFs were compared between different lobes and visits. Simulation results demonstrated that the proposed method can improve accuracy of VIF estimation and pharmacokinetic fitting. In animal study results, pharmacokinetic fitting using corrected VIFs demonstrated changes in perfusion consistent with changes expected after PVE, whereas the perfusion estimates derived by uncorrected VIFs showed no significant changes. The proposed correction method improves accuracy of VIFs and therefore provides more precise pharmacokinetic fitting. This method may be promising in improving the reliability of perfusion quantification. Magn Reson Med 79:3093-3102, 2018. © 2017 International Society for Magnetic Resonance in Medicine. © 2017 International Society for Magnetic Resonance in Medicine.

  13. In vivo, high-frequency three-dimensional cardiac MR elastography: Feasibility in normal volunteers.

    PubMed

    Arani, Arvin; Glaser, Kevin L; Arunachalam, Shivaram P; Rossman, Phillip J; Lake, David S; Trzasko, Joshua D; Manduca, Armando; McGee, Kiaran P; Ehman, Richard L; Araoz, Philip A

    2017-01-01

    Noninvasive stiffness imaging techniques (elastography) can image myocardial tissue biomechanics in vivo. For cardiac MR elastography (MRE) techniques, the optimal vibration frequency for in vivo experiments is unknown. Furthermore, the accuracy of cardiac MRE has never been evaluated in a geometrically accurate phantom. Therefore, the purpose of this study was to determine the necessary driving frequency to obtain accurate three-dimensional (3D) cardiac MRE stiffness estimates in a geometrically accurate diastolic cardiac phantom and to determine the optimal vibration frequency that can be introduced in healthy volunteers. The 3D cardiac MRE was performed on eight healthy volunteers using 80 Hz, 100 Hz, 140 Hz, 180 Hz, and 220 Hz vibration frequencies. These frequencies were tested in a geometrically accurate diastolic heart phantom and compared with dynamic mechanical analysis (DMA). The 3D Cardiac MRE was shown to be feasible in volunteers at frequencies as high as 180 Hz. MRE and DMA agreed within 5% at frequencies greater than 180 Hz in the cardiac phantom. However, octahedral shear strain signal to noise ratios and myocardial coverage was shown to be highest at a frequency of 140 Hz across all subjects. This study motivates future evaluation of high-frequency 3D MRE in patient populations. Magn Reson Med 77:351-360, 2017. © 2016 Wiley Periodicals, Inc. © 2016 Wiley Periodicals, Inc.

  14. Eliminating the blood-flow confounding effect in intravoxel incoherent motion (IVIM) using the non-negative least square analysis in liver.

    PubMed

    Gambarota, Giulio; Hitti, Eric; Leporq, Benjamin; Saint-Jalmes, Hervé; Beuf, Olivier

    2017-01-01

    Tissue perfusion measurements using intravoxel incoherent motion (IVIM) diffusion-MRI are of interest for investigations of liver pathologies. A confounding factor in the perfusion quantification is the partial volume between liver tissue and large blood vessels. The aim of this study was to assess and correct for this partial volume effect in the estimation of the perfusion fraction. MRI experiments were performed at 3 Tesla with a diffusion-MRI sequence at 12 b-values. Diffusion signal decays in liver were analyzed using the non-negative least square (NNLS) method and the biexponential fitting approach. In some voxels, the NNLS analysis yielded a very fast-decaying component that was assigned to partial volume with the blood flowing in large vessels. Partial volume correction was performed by biexponential curve fitting, where the first data point (b = 0 s/mm 2 ) was eliminated in voxels with a very fast-decaying component. Biexponential fitting with partial volume correction yielded parametric maps with perfusion fraction values smaller than biexponential fitting without partial volume correction. The results of the current study indicate that the NNLS analysis in combination with biexponential curve fitting allows to correct for partial volume effects originating from blood flow in IVIM perfusion fraction measurements. Magn Reson Med 77:310-317, 2017. © 2016 Wiley Periodicals, Inc. © 2016 Wiley Periodicals, Inc.

  15. UTE imaging with simultaneous water and fat signal suppression using a time-efficient multispoke inversion recovery pulse sequence.

    PubMed

    Carl, Michael; Bydder, Graeme M; Du, Jiang

    2016-08-01

    The long repetition time and inversion time with inversion recovery preparation ultrashort echo time (UTE) often causes prohibitively long scan times. We present an optimized method for long T2 signal suppression in which several k-space spokes are acquired after each inversion preparation. Using Bloch equations the sequence parameters such as TI and flip angle were optimized to suppress the long T2 water and fat signals and to maximize short T2 contrast. Volunteer imaging was performed on a healthy male volunteer. Inversion recovery preparation was performed using a Silver-Hoult adiabatic inversion pulse together with a three-dimensional (3D) UTE (3D Cones) acquisition. The theoretical signal curves generally agreed with the experimentally measured region of interest curves. The multispoke inversion recovery method showed good muscle and fatty bone marrow suppression, and highlighted short T2 signals such as these from the femoral and tibial cortex. Inversion recovery 3D UTE imaging with multiple spoke acquisitions can be used to effectively suppress long T2 signals and highlight short T2 signals within clinical scan times. Theoretical modeling can be used to determine sequence parameters to optimize long T2 signal suppression and maximize short T2 signals. Experimental results on a volunteer confirmed the theoretical predictions. Magn Reson Med 76:577-582, 2016. © 2015 Wiley Periodicals, Inc. © 2015 Wiley Periodicals, Inc.

  16. A fast and flexible MRI system for the study of dynamic vocal tract shaping.

    PubMed

    Lingala, Sajan Goud; Zhu, Yinghua; Kim, Yoon-Chul; Toutios, Asterios; Narayanan, Shrikanth; Nayak, Krishna S

    2017-01-01

    The aim of this work was to develop and evaluate an MRI-based system for study of dynamic vocal tract shaping during speech production, which provides high spatial and temporal resolution. The proposed system utilizes (a) custom eight-channel upper airway coils that have high sensitivity to upper airway regions of interest, (b) two-dimensional golden angle spiral gradient echo acquisition, (c) on-the-fly view-sharing reconstruction, and (d) off-line temporal finite difference constrained reconstruction. The system also provides simultaneous noise-cancelled and temporally aligned audio. The system is evaluated in 3 healthy volunteers, and 1 tongue cancer patient, with a broad range of speech tasks. We report spatiotemporal resolutions of 2.4 × 2.4 mm 2 every 12 ms for single-slice imaging, and 2.4 × 2.4 mm 2 every 36 ms for three-slice imaging, which reflects roughly 7-fold acceleration over Nyquist sampling. This system demonstrates improved temporal fidelity in capturing rapid vocal tract shaping for tasks, such as producing consonant clusters in speech, and beat-boxing sounds. Novel acoustic-articulatory analysis was also demonstrated. A synergistic combination of custom coils, spiral acquisitions, and constrained reconstruction enables visualization of rapid speech with high spatiotemporal resolution in multiple planes. Magn Reson Med 77:112-125, 2017. © 2016 Wiley Periodicals, Inc. © 2016 Wiley Periodicals, Inc.

  17. pH imaging of mouse kidneys in vivo using a frequency-dependent paraCEST agent.

    PubMed

    Wu, Yunkou; Zhang, Shanrong; Soesbe, Todd C; Yu, Jing; Vinogradov, Elena; Lenkinski, Robert E; Sherry, A Dean

    2016-06-01

    This study explored the feasibility of using a pH responsive paramagnetic chemical exchange saturation transfer (paraCEST) agent to image the pH gradient in kidneys of healthy mice. CEST signals were acquired on an Agilent 9.4 Tesla small animal MRI system using a steady-state gradient echo pulse sequence after a bolus injection of agent. The magnetic field inhomogeneity across each kidney was corrected using the WASSR method and pH maps were calculated by measuring the frequency of water exchange signal arising from the agent. Dynamic CEST studies demonstrated that the agent was readily detectable in kidneys only between 4 to 12 min postinjection. The CEST images showed a higher signal intensity in the pelvis and calyx regions and lower signal intensity in the medulla and cortex regions. The pH maps reflected tissue pH values spanning from 6.0 to 7.5 in kidneys of healthy mice. This study demonstrated that pH maps of the kidney can be imaged in vivo by measuring the pH-dependent chemical shift of a single water exchange CEST peak without prior knowledge of the agent concentration in vivo. The results demonstrate the potential of using a simple frequency-dependent paraCEST agent for mapping tissue pH in vivo. Magn Reson Med 75:2432-2441, 2016. © 2015 Wiley Periodicals, Inc. © 2015 Wiley Periodicals, Inc.

  18. Diffusion anisotropy in fresh and fixed prostate tissue ex vivo.

    PubMed

    Bourne, Roger M; Bongers, Andre; Chatterjee, Aritrick; Sved, Paul; Watson, Geoffrey

    2016-08-01

    To investigate diffusion anisotropy in whole human prostate specimens Seven whole radical prostatectomy specimens were obtained with informed patient consent and institutional ethics approval. Diffusion tensor imaging was performed at 9.4 Tesla. Diffusion tensors were calculated from the native acquired data and after progressive downsampling Fractional anisotropy (FA) decreased as voxel volume increased, and differed widely between prostates. Fixation decreased mean FA by ∼0.05-0.08 at all voxel volumes but did not alter principle eigenvector orientation. In unfixed tissue high FA (> 0.6) was found only in voxels of volume <0.5 mm(3) , and then only in a small fraction of all voxels. At typical clinical voxel volumes (4-16 mm(3) ) less than 50% of voxels had FA > 0.25. FA decreased at longer diffusion times (Δ = 60 or 80 ms compared with 20 ms), but only by ∼0.02 at typical clinical voxel volume. Peripheral zone FA was significantly lower than transition zone FA in five of the seven prostates FA varies widely between prostates. The very small proportion of clinical size voxels with high FA suggests that in clinical DWI studies ADC based on three-direction measurements will be minimally affected by anisotropy. Magn Reson Med 76:626-634, 2016. © 2015 Wiley Periodicals, Inc. © 2015 Wiley Periodicals, Inc.

  19. A model describing diffusion in prostate cancer.

    PubMed

    Gilani, Nima; Malcolm, Paul; Johnson, Glyn

    2017-07-01

    Quantitative diffusion MRI has frequently been studied as a means of grading prostate cancer. Interpretation of results is complicated by the nature of prostate tissue, which consists of four distinct compartments: vascular, ductal lumen, epithelium, and stroma. Current diffusion measurements are an ill-defined weighted average of these compartments. In this study, prostate diffusion is analyzed in terms of a model that takes explicit account of tissue compartmentalization, exchange effects, and the non-Gaussian behavior of tissue diffusion. The model assumes that exchange between the cellular (ie, stromal plus epithelial) and the vascular and ductal compartments is slow. Ductal and cellular diffusion characteristics are estimated by Monte Carlo simulation and a two-compartment exchange model, respectively. Vascular pseudodiffusion is represented by an additional signal at b = 0. Most model parameters are obtained either from published data or by comparing model predictions with the published results from 41 studies. Model prediction error is estimated using 10-fold cross-validation. Agreement between model predictions and published results is good. The model satisfactorily explains the variability of ADC estimates found in the literature. A reliable model that predicts the diffusion behavior of benign and cancerous prostate tissue of different Gleason scores has been developed. Magn Reson Med 78:316-326, 2017. © 2016 International Society for Magnetic Resonance in Medicine. © 2016 International Society for Magnetic Resonance in Medicine.

  20. A Bayesian model for highly accelerated phase-contrast MRI.

    PubMed

    Rich, Adam; Potter, Lee C; Jin, Ning; Ash, Joshua; Simonetti, Orlando P; Ahmad, Rizwan

    2016-08-01

    Phase-contrast magnetic resonance imaging is a noninvasive tool to assess cardiovascular disease by quantifying blood flow; however, low data acquisition efficiency limits the spatial and temporal resolutions, real-time application, and extensions to four-dimensional flow imaging in clinical settings. We propose a new data processing approach called Reconstructing Velocity Encoded MRI with Approximate message passing aLgorithms (ReVEAL) that accelerates the acquisition by exploiting data structure unique to phase-contrast magnetic resonance imaging. The proposed approach models physical correlations across space, time, and velocity encodings. The proposed Bayesian approach exploits the relationships in both magnitude and phase among velocity encodings. A fast iterative recovery algorithm is introduced based on message passing. For validation, prospectively undersampled data are processed from a pulsatile flow phantom and five healthy volunteers. The proposed approach is in good agreement, quantified by peak velocity and stroke volume (SV), with reference data for acceleration rates R≤10. For SV, Pearson r≥0.99 for phantom imaging (n = 24) and r≥0.96 for prospectively accelerated in vivo imaging (n = 10) for R≤10. The proposed approach enables accurate quantification of blood flow from highly undersampled data. The technique is extensible to four-dimensional flow imaging, where higher acceleration may be possible due to additional redundancy. Magn Reson Med 76:689-701, 2016. © 2015 Wiley Periodicals, Inc. © 2015 Wiley Periodicals, Inc.

  1. Diffusion-weighted MR imaging of upper abdominal organs at different time points: Apparent diffusion coefficient normalization using a reference organ.

    PubMed

    Song, Ji Soo; Kwak, Hyo Sung; Byon, Jung Hee; Jin, Gong Yong

    2017-05-01

    To compare the apparent diffusion coefficient (ADC) of upper abdominal organs acquired at different time points, and to investigate the usefulness of normalization. We retrospectively evaluated 58 patients who underwent three rounds of magnetic resonance (MR) imaging including diffusion-weighted imaging of the upper abdomen. MR examinations were performed using three different 3.0 Tesla (T) and one 1.5T systems, with variable b value combinations and respiratory motion compensation techniques. The ADC values of the upper abdominal organs from three different time points were analyzed, using the ADC values of the paraspinal muscle (ADC psm ) and spleen (ADC spleen ) for normalization. Intraclass correlation coefficients (ICC) and comparison of dependent ICCs were used for statistical analysis. The ICCs of the original ADC and ADC psm showed fair to substantial agreement, while ADC spleen showed substantial to almost perfect agreement. The ICC of ADC spleen of all anatomical regions showed less variability compared with that of the original ADC (P < 0.005). Normalized ADC using the spleen as a reference organ significantly decreased variability in measurement of the upper abdominal organs in different MR systems at different time points and could be regarded as an imaging biomarker for future multicenter, longitudinal studies. 5 J. MAGN. RESON. IMAGING 2017;45:1494-1501. © 2016 International Society for Magnetic Resonance in Medicine.

  2. MRI surveillance of cancer cell fate in a brain metastasis model after early radiotherapy.

    PubMed

    Murrell, Donna H; Zarghami, Niloufar; Jensen, Michael D; Dickson, Fiona; Chambers, Ann F; Wong, Eugene; Foster, Paula J

    2017-10-01

    Incidence of brain metastasis attributed to breast cancer is increasing and prognosis is poor. It is thought that disseminated dormant cancer cells persist in metastatic organs and may evade treatments, thereby facilitating a mechanism for recurrence. Radiotherapy is used to treat brain metastases clinically, but assessment has been limited to macroscopic tumor volumes detectable by clinical imaging. Here, we use cellular MRI to understand the concurrent responses of metastases and nonproliferative or slowly cycling cancer cells to radiotherapy. MRI cell tracking was used to investigate the impact of early cranial irradiation on the fate of individual iron-labeled cancer cells and outgrowth of breast cancer brain metastases in the human MDA-MB-231-BR-HER2 cell model. Early whole-brain radiotherapy significantly reduced the outgrowth of metastases from individual disseminated cancer cells in treated animals compared to controls. However, the numbers of nonproliferative iron-retaining cancer cells in the brain were not significantly different. Radiotherapy, when given early in cancer progression, is effective in preventing the outgrowth of solitary cancer cells to brain metastases. Future studies of the nonproliferative cancer cells' clonogenic potentials are warranted, given that their persistent presence suggests that they may have evaded treatment. Magn Reson Med 78:1506-1512, 2017. © 2016 International Society for Magnetic Resonance in Medicine. © 2016 International Society for Magnetic Resonance in Medicine.

  3. Volumetric MRI of the lungs during forced expiration.

    PubMed

    Berman, Benjamin P; Pandey, Abhishek; Li, Zhitao; Jeffries, Lindsie; Trouard, Theodore P; Oliva, Isabel; Cortopassi, Felipe; Martin, Diego R; Altbach, Maria I; Bilgin, Ali

    2016-06-01

    Lung function is typically characterized by spirometer measurements, which do not offer spatially specific information. Imaging during exhalation provides spatial information but is challenging due to large movement over a short time. The purpose of this work is to provide a solution to lung imaging during forced expiration using accelerated magnetic resonance imaging. The method uses radial golden angle stack-of-stars gradient echo acquisition and compressed sensing reconstruction. A technique for dynamic three-dimensional imaging of the lungs from highly undersampled data is developed and tested on six subjects. This method takes advantage of image sparsity, both spatially and temporally, including the use of reference frames called bookends. Sparsity, with respect to total variation, and residual from the bookends, enables reconstruction from an extremely limited amount of data. Dynamic three-dimensional images can be captured at sub-150 ms temporal resolution, using only three (or less) acquired radial lines per slice per timepoint. The images have a spatial resolution of 4.6×4.6×10 mm. Lung volume calculations based on image segmentation are compared to those from simultaneously acquired spirometer measurements. Dynamic lung imaging during forced expiration is made possible by compressed sensing accelerated dynamic three-dimensional radial magnetic resonance imaging. Magn Reson Med 75:2295-2302, 2016. © 2015 Wiley Periodicals, Inc. © 2015 Wiley Periodicals, Inc.

  4. Improving labeling efficiency in automatic quality control of MRSI data.

    PubMed

    Pedrosa de Barros, Nuno; McKinley, Richard; Wiest, Roland; Slotboom, Johannes

    2017-12-01

    To improve the efficiency of the labeling task in automatic quality control of MR spectroscopy imaging data. 28'432 short and long echo time (TE) spectra (1.5 tesla; point resolved spectroscopy (PRESS); repetition time (TR)= 1,500 ms) from 18 different brain tumor patients were labeled by two experts as either accept or reject, depending on their quality. For each spectrum, 47 signal features were extracted. The data was then used to run several simulations and test an active learning approach using uncertainty sampling. The performance of the classifiers was evaluated as a function of the number of patients in the training set, number of spectra in the training set, and a parameter α used to control the level of classification uncertainty required for a new spectrum to be selected for labeling. The results showed that the proposed strategy allows reductions of up to 72.97% for short TE and 62.09% for long TE in the amount of data that needs to be labeled, without significant impact in classification accuracy. Further reductions are possible with significant but minimal impact in performance. Active learning using uncertainty sampling is an effective way to increase the labeling efficiency for training automatic quality control classifiers. Magn Reson Med 78:2399-2405, 2017. © 2017 International Society for Magnetic Resonance in Medicine. © 2017 International Society for Magnetic Resonance in Medicine.

  5. Blood oxygen-level dependent functional assessment of cerebrovascular reactivity: Feasibility for intraoperative 3 Tesla MRI.

    PubMed

    Fierstra, Jorn; Burkhardt, Jan-Karl; van Niftrik, Christiaan Hendrik Bas; Piccirelli, Marco; Pangalu, Athina; Kocian, Roman; Neidert, Marian Christoph; Valavanis, Antonios; Regli, Luca; Bozinov, Oliver

    2017-02-01

    To assess the feasibility of functional blood oxygen-level dependent (BOLD) MRI to evaluate intraoperative cerebrovascular reactivity (CVR) at 3 Tesla field strength. Ten consecutive neurosurgical subjects scheduled for a clinical intraoperative MRI examination were enrolled in this study. In addition to the clinical protocol a BOLD sequence was implemented with three cycles of 44 s apnea to calculate CVR values on a voxel-by-voxel basis throughout the brain. The CVR range was then color-coded and superimposed on an anatomical volume to create high spatial resolution CVR maps. Ten subjects (mean age 34.8 ± 13.4; 2 females) uneventfully underwent the intraoperative BOLD protocol, with no complications occurring. Whole-brain CVR for all subjects was (mean ± SD) 0.69 ± 0.42, whereas CVR was markedly higher for tumor subjects as compared to vascular subjects, 0.81 ± 0.44 versus 0.33 ± 0.10, respectively. Furthermore, color-coded functional maps could be robustly interpreted for a whole-brain assessment of CVR. We demonstrate that intraoperative BOLD MRI is feasible in creating functional maps to assess cerebrovascular reactivity throughout the brain in subjects undergoing a neurosurgical procedure. Magn Reson Med 77:806-813, 2017. © 2016 International Society for Magnetic Resonance in Medicine. © 2016 International Society for Magnetic Resonance in Medicine.

  6. A prototype of injector to control and to detect the release of magnetic beads within the constraints of multibifurcation magnetic resonance navigation procedures.

    PubMed

    Bigot, Alexandre; Soulez, Gilles; Martel, Sylvain

    2017-01-01

    An injector equipped with a bead capture and a bead detection system is presented. In the context of magnetic resonance navigation (MRN), in which MRI gradients are used to steer intravascular therapeutic carriers, fast and reliable injection is essential. In this paper, we present a prototype of injector to control and to detect the release of magnetic beads. The injector relies on two distinct subsystems: (1) the capture subsystem, which creates local magnetic force to stop the flow of magnetic beads; and (2) the detection subsystem, which detects flowing beads and generates a trigger signal to start MRI gradient pulses. Both systems rely on small microcoils wound on the tubing. Five-turn microcoils show the best compromise between size and performance. Less than 5 mW of power is required to capture 0.8-mm beads moving in a flow above 5 mL min -1 or when a gradient above 200 mT m -1 is applied. The detection system is not sensitive to noise and detects every 0.8-mm bead in flow rates up to 14 mL m -1 . The prototype of injector shows performance above the requirements inherent to magnetic resonance navigation. This system is a step toward in vivo multibifurcation MRN. Magn Reson Med 77:444-452, 2017. © 2016 Wiley Periodicals, Inc. © 2016 Wiley Periodicals, Inc.

  7. Design of a Type-1 Diabetes Vaccine Candidate Using Edible Plants Expressing a Major Autoantigen

    PubMed Central

    Bertini, Edoardo; Merlin, Matilde; Gecchele, Elisa; Puggia, Andrea; Brozzetti, Annalisa; Commisso, Mauro; Falorni, Alberto; Bini, Vittorio; Klymyuk, Victor; Pezzotti, Mario; Avesani, Linda

    2018-01-01

    Type-1 diabetes (T1D) is a metabolic disease involving the autoimmune destruction of insulin-producing pancreatic beta cells. It is often diagnosed by the detection of autoantibodies, typically those recognizing insulin itself or the 65-kDa isoform of glutamic acid decarboxylase (GAD65). Oral insulin can be used to induce systemic immunological tolerance and thus prevent or delay the onset of T1D, suggesting that combination treatments with other autoantigens such as GAD65 could be even more successful. GAD65 has induced oral tolerance and prevented T1D in preclinical studies but it is difficult to produce in sufficient quantities for clinical testing. Here we combined edible plant systems, namely spinach (Spinacia oleracea cv Industra) and red beet (Beta vulgaris cv Moulin Rouge), with the magnICON® expression system to develop a safe, cost-effective and environmentally sustainable platform for the large-scale production of GAD65. The superior red beet platform was extensively characterized in terms of recombinant protein yields and bioequivalence to wild-type plants, and the product was tested for its ability to resist simulated gastric digestion. Our results indicate that red beet plants are suitable for the production of a candidate oral vaccine based on GAD65 for the future preclinical and clinical testing of T1D immunotherapy approaches. PMID:29765386

  8. Bidirectional Contrast agent leakage correction of dynamic susceptibility contrast (DSC)-MRI improves cerebral blood volume estimation and survival prediction in recurrent glioblastoma treated with bevacizumab.

    PubMed

    Leu, Kevin; Boxerman, Jerrold L; Lai, Albert; Nghiemphu, Phioanh L; Pope, Whitney B; Cloughesy, Timothy F; Ellingson, Benjamin M

    2016-11-01

    To evaluate a leakage correction algorithm for T 1 and T2* artifacts arising from contrast agent extravasation in dynamic susceptibility contrast magnetic resonance imaging (DSC-MRI) that accounts for bidirectional contrast agent flux and compare relative cerebral blood volume (CBV) estimates and overall survival (OS) stratification from this model to those made with the unidirectional and uncorrected models in patients with recurrent glioblastoma (GBM). We determined median rCBV within contrast-enhancing tumor before and after bevacizumab treatment in patients (75 scans on 1.5T, 19 scans on 3.0T) with recurrent GBM without leakage correction and with application of the unidirectional and bidirectional leakage correction algorithms to determine whether rCBV stratifies OS. Decreased post-bevacizumab rCBV from baseline using the bidirectional leakage correction algorithm significantly correlated with longer OS (Cox, P = 0.01), whereas rCBV change using the unidirectional model (P = 0.43) or the uncorrected rCBV values (P = 0.28) did not. Estimates of rCBV computed with the two leakage correction algorithms differed on average by 14.9%. Accounting for T 1 and T2* leakage contamination in DSC-MRI using a two-compartment, bidirectional rather than unidirectional exchange model might improve post-bevacizumab survival stratification in patients with recurrent GBM. J. Magn. Reson. Imaging 2016;44:1229-1237. © 2016 International Society for Magnetic Resonance in Medicine.

  9. Quantitative MRI and spectroscopy of bone marrow

    PubMed Central

    Ruschke, Stefan; Dieckmeyer, Michael; Diefenbach, Maximilian; Franz, Daniela; Gersing, Alexandra S.; Krug, Roland; Baum, Thomas

    2017-01-01

    Bone marrow is one of the largest organs in the human body, enclosing adipocytes, hematopoietic stem cells, which are responsible for blood cell production, and mesenchymal stem cells, which are responsible for the production of adipocytes and bone cells. Magnetic resonance imaging (MRI) is the ideal imaging modality to monitor bone marrow changes in healthy and pathological states, thanks to its inherent rich soft‐tissue contrast. Quantitative bone marrow MRI and magnetic resonance spectroscopy (MRS) techniques have been also developed in order to quantify changes in bone marrow water–fat composition, cellularity and perfusion in different pathologies, and to assist in understanding the role of bone marrow in the pathophysiology of systemic diseases (e.g. osteoporosis). The present review summarizes a large selection of studies published until March 2017 in proton‐based quantitative MRI and MRS of bone marrow. Some basic knowledge about bone marrow anatomy and physiology is first reviewed. The most important technical aspects of quantitative MR methods measuring bone marrow water–fat composition, fatty acid composition, perfusion, and diffusion are then described. Finally, previous MR studies are reviewed on the application of quantitative MR techniques in both healthy aging and diseased bone marrow affected by osteoporosis, fractures, metabolic diseases, multiple myeloma, and bone metastases. Level of Evidence: 3 Technical Efficacy: Stage 2 J. Magn. Reson. Imaging 2018;47:332–353. PMID:28570033

  10. The public multi-coil information (PUMCIN) policy.

    PubMed

    Juchem, Christoph; de Graaf, Robin A

    2017-11-01

    Multi-coil (MC) magnetic field modeling has emerged as a viable alternative to conventional field generation based on spherical harmonic shapes, and an active MC community is forming. Although all MC applications share the same modeling concept, the specific MC designs can largely differ as a result of disparities in region of interest (eg, human versus rodent), intended MR application (eg, B 0 shimming versus spatial encoding), or other experimental constraints (eg, available bore space or integration with radiofrequency technology). To date, a lack of detailed information on existing MC designs complicates the assessment and precludes a meaningful comparison. Here, we suggest that future publications involving the MC technique not only report the benefits for the application at hand, but also include an explicit description of the MC wire pattern used. This public multi-coil information (PUMCIN) policy represents a voluntary commitment to promoting free public access to the details necessary for reproducing and benefiting from MC research. The PUMCIN policy is expected to initiate a paradigm shift with respect to the way MC innovation is reported. By setting an example, we hope to encourage the evolving MC community to maximize the benefits for science and society by embracing it. Magn Reson Med 78:2042-2047, 2017. © 2016 International Society for Magnetic Resonance in Medicine. © 2016 International Society for Magnetic Resonance in Medicine.

  11. Partial fourier and parallel MR image reconstruction with integrated gradient nonlinearity correction.

    PubMed

    Tao, Shengzhen; Trzasko, Joshua D; Shu, Yunhong; Weavers, Paul T; Huston, John; Gray, Erin M; Bernstein, Matt A

    2016-06-01

    To describe how integrated gradient nonlinearity (GNL) correction can be used within noniterative partial Fourier (homodyne) and parallel (SENSE and GRAPPA) MR image reconstruction strategies, and demonstrate that performing GNL correction during, rather than after, these routines mitigates the image blurring and resolution loss caused by postreconstruction image domain based GNL correction. Starting from partial Fourier and parallel magnetic resonance imaging signal models that explicitly account for GNL, noniterative image reconstruction strategies for each accelerated acquisition technique are derived under the same core mathematical assumptions as their standard counterparts. A series of phantom and in vivo experiments on retrospectively undersampled data were performed to investigate the spatial resolution benefit of integrated GNL correction over conventional postreconstruction correction. Phantom and in vivo results demonstrate that the integrated GNL correction reduces the image blurring introduced by the conventional GNL correction, while still correcting GNL-induced coarse-scale geometrical distortion. Images generated from undersampled data using the proposed integrated GNL strategies offer superior depiction of fine image detail, for example, phantom resolution inserts and anatomical tissue boundaries. Noniterative partial Fourier and parallel imaging reconstruction methods with integrated GNL correction reduce the resolution loss that occurs during conventional postreconstruction GNL correction while preserving the computational efficiency of standard reconstruction techniques. Magn Reson Med 75:2534-2544, 2016. © 2015 Wiley Periodicals, Inc. © 2015 Wiley Periodicals, Inc.

  12. Ex vivo hyperpolarized MR spectroscopy on isolated renal tubular cells: A novel technique for cell energy phenotyping.

    PubMed

    Juul, Troels; Palm, Fredrik; Nielsen, Per Mose; Bertelsen, Lotte Bonde; Laustsen, Christoffer

    2017-08-01

    It has been demonstrated that hyperpolarized 13 C MR is a useful tool to study cultured cells. However, cells in culture can alter phenotype, which raises concerns regarding the in vivo significance of such findings. Here we investigate if metabolic phenotyping using hyperpolarized 13 C MR is suitable for cells isolated from kidney tissue, without prior cell culture. Isolation of tubular cells from freshly excised kidney tissue and treatment with either ouabain or antimycin A was investigated with hyperpolarized MR spectroscopy on a 9.4 Tesla preclinical imaging system. Isolation of tubular cells from less than 2 g of kidney tissue generally resulted in more than 10 million live tubular cells. This amount of cells was enough to yield robust signals from the conversion of 13 C-pyruvate to lactate, bicarbonate and alanine, demonstrating that metabolic flux by means of both anaerobic and aerobic pathways can be quantified using this technique. Ex vivo metabolic phenotyping using hyperpolarized 13 C MR in a preclinical system is a useful technique to study energy metabolism in freshly isolated renal tubular cells. This technique has the potential to advance our understanding of both normal cell physiology as well as pathological processes contributing to kidney disease. Magn Reson Med 78:457-461, 2017. © 2016 International Society for Magnetic Resonance in Medicine. © 2016 International Society for Magnetic Resonance in Medicine.

  13. Creation and Ordering of Oxygen Vacancies at WO 3-δ and Perovskite Interfaces

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Zhang, Kelvin H. L.; Li, Guoqiang; Spurgeon, Steven R.

    Changes in structure and composition resulting from oxygen deficiency can strongly impact the physical and chemical properties of transition metal oxides, which may lead to new functionalities for novel electronic devices. Oxygen vacancies (V o) can be readily formed to accomodate the lattice mismatch during epitixial thin film growth. In this paper, the effects of substrate strain and oxidizing power on the creation and distribution of V o in WO 3-δ thin films are investigated in detail. An 18O 2 isotope labeled time-of-flight secondary ion mass spectrometry study reveals that WO 3-δ films grown on SrTiO 3 substrates display amore » significantly larger oxygen vacancy gradient along the growth direction compared to those grown on LaAlO 3 substrates. This result is corroborated by scanning transmission electron microscopy imaging which reveals a large number of defects close to the interface to accommodate interfacial tensile strain, leading to the ordering of V o and the formation of semi-aligned Magnéli phases. The strain is gradually released and tetragonal phase with much better crystallinity is observed at the film/vacuum interface. The changes in structure resulting from oxygen defect creation are shown to have a direct impact on the electronic and optical properties of the films.« less

  14. Assessment of turbulent flow effects on the vessel wall using four-dimensional flow MRI.

    PubMed

    Ziegler, Magnus; Lantz, Jonas; Ebbers, Tino; Dyverfeldt, Petter

    2017-06-01

    To explore the use of MR-estimated turbulence quantities for the assessment of turbulent flow effects on the vessel wall. Numerical velocity data for two patient-derived models was obtained using computational fluid dynamics (CFD) for two physiological flow rates. The four-dimensional (4D) Flow MRI measurements were simulated at three different spatial resolutions and used to investigate the estimation of turbulent wall shear stress (tWSS) using the intravoxel standard deviation (IVSD) of velocity and turbulent kinetic energy (TKE) estimated near the vessel wall. Accurate estimation of tWSS using the IVSD is limited by the spatial resolution achievable with 4D Flow MRI. TKE, estimated near the wall, has a strong linear relationship to the tWSS (mean R 2  = 0.84). Near-wall TKE estimates from MR simulations have good agreement to CFD-derived ground truth (mean R 2  = 0.90). Maps of near-wall TKE have strong visual correspondence to tWSS. Near-wall estimation of TKE permits assessment of relative maps of tWSS, but direct estimation of tWSS is challenging due to limitations in spatial resolution. Assessment of tWSS and near-wall TKE may open new avenues for analysis of different pathologies. Magn Reson Med 77:2310-2319, 2017. © 2016 International Society for Magnetic Resonance in Medicine. © 2016 International Society for Magnetic Resonance in Medicine.

  15. Energy transport towards magnetosphere: current background and perspectives

    NASA Astrophysics Data System (ADS)

    Savin, Sergey; Zelenyi, Lev

    On the background of rising number of multi-scale magnetospheric constellations of satellites (e.g. MMS, ROY, SCOPE etc.), we discuss realistic options for the future experimental efforts in the current international framework. Now space weather predictions require cross-scale (i.e. multi-point) and micro-scale (down to the electron inertial length and gyroradius, i.e. few km and 0.1 s) measurements, which should facilitate the fundamental turbulence explorations impacting e.g. fusion and astrophysical tasks. Both ROY and SCOPE could provide 4-6 space-craft under wide international collaboration. For SCOPE near-equatorial plane is the region for the multi-scale studies, while ROY will start from high latitudes and finish at the intermediate and, hopefully, low ones. We suggest a new strategy for the correlated measurements instead of a multi-tetrahedron configuration: -place spacecraft along magnetospheric boundaries: magne-topause, neutral sheet, bow shock et. instead of tetrahedron Cluster-like configuration trying to get the multi-scale measurements along the natural boundaries; -monitor the processes along the streamlines in magnetosheath; -use extra 2-8 nano/ pico-satellites for campaigns of the multi-spacecraft explorations, -utilize multi-frequency radio-tomography for monitoring of the inter-spacecraft processes Both SCOPE and ROY launchers have respective payload resources, which, with the respective international cooperation, should provide a new step in the magnetospheric plasma explorations.

  16. Anomalous T2 relaxation in normal and degraded cartilage.

    PubMed

    Reiter, David A; Magin, Richard L; Li, Weiguo; Trujillo, Juan J; Pilar Velasco, M; Spencer, Richard G

    2016-09-01

    To compare the ordinary monoexponential model with three anomalous relaxation models-the stretched Mittag-Leffler, stretched exponential, and biexponential functions-using both simulated and experimental cartilage relaxation data. Monte Carlo simulations were used to examine both the ability of identifying a given model under high signal-to-noise ratio (SNR) conditions and the accuracy and precision of parameter estimates under more modest SNR as would be encountered clinically. Experimental transverse relaxation data were analyzed from normal and enzymatically degraded cartilage samples under high SNR and rapid echo sampling to compare each model. Both simulation and experimental results showed improvement in signal representation with the anomalous relaxation models. The stretched exponential model consistently showed the lowest mean squared error in experimental data and closely represents the signal decay over multiple decades of the decay time (e.g., 1-10 ms, 10-100 ms, and >100 ms). The stretched exponential parameter αse showed an inverse correlation with biochemically derived cartilage proteoglycan content. Experimental results obtained at high field suggest potential application of αse as a measure of matrix integrity. Simulation reflecting more clinical imaging conditions, indicate the ability to robustly estimate αse and distinguish between normal and degraded tissue, highlighting its potential as a biomarker for human studies. Magn Reson Med 76:953-962, 2016. © 2015 Wiley Periodicals, Inc. © 2015 Wiley Periodicals, Inc.

  17. Feasibility of conductivity imaging using subject eddy currents induced by switching of MRI gradients.

    PubMed

    Oran, Omer Faruk; Ider, Yusuf Ziya

    2017-05-01

    To investigate the feasibility of low-frequency conductivity imaging based on measuring the magnetic field due to subject eddy currents induced by switching of MRI z-gradients. We developed a simulation model for calculating subject eddy currents and the magnetic fields they generate (subject eddy fields). The inverse problem of obtaining conductivity distribution from subject eddy fields was formulated as a convection-reaction partial differential equation. For measuring subject eddy fields, a modified spin-echo pulse sequence was used to determine the contribution of subject eddy fields to MR phase images. In the simulations, successful conductivity reconstructions were obtained by solving the derived convection-reaction equation, suggesting that the proposed reconstruction algorithm performs well under ideal conditions. However, the level of the calculated phase due to the subject eddy field in a representative object indicates that this phase is below the noise level and cannot be measured with an uncertainty sufficiently low for accurate conductivity reconstruction. Furthermore, some artifacts other than random noise were observed in the measured phases, which are discussed in relation to the effects of system imperfections during readout. Low-frequency conductivity imaging does not seem feasible using basic pulse sequences such as spin-echo on a clinical MRI scanner. Magn Reson Med 77:1926-1937, 2017. © 2016 International Society for Magnetic Resonance in Medicine. © 2016 International Society for Magnetic Resonance in Medicine.

  18. Quality of clinical brain tumor MR spectra judged by humans and machine learning tools.

    PubMed

    Kyathanahally, Sreenath P; Mocioiu, Victor; Pedrosa de Barros, Nuno; Slotboom, Johannes; Wright, Alan J; Julià-Sapé, Margarida; Arús, Carles; Kreis, Roland

    2018-05-01

    To investigate and compare human judgment and machine learning tools for quality assessment of clinical MR spectra of brain tumors. A very large set of 2574 single voxel spectra with short and long echo time from the eTUMOUR and INTERPRET databases were used for this analysis. Original human quality ratings from these studies as well as new human guidelines were used to train different machine learning algorithms for automatic quality control (AQC) based on various feature extraction methods and classification tools. The performance was compared with variance in human judgment. AQC built using the RUSBoost classifier that combats imbalanced training data performed best. When furnished with a large range of spectral and derived features where the most crucial ones had been selected by the TreeBagger algorithm it showed better specificity (98%) in judging spectra from an independent test-set than previously published methods. Optimal performance was reached with a virtual three-class ranking system. Our results suggest that feature space should be relatively large for the case of MR tumor spectra and that three-class labels may be beneficial for AQC. The best AQC algorithm showed a performance in rejecting spectra that was comparable to that of a panel of human expert spectroscopists. Magn Reson Med 79:2500-2510, 2018. © 2017 International Society for Magnetic Resonance in Medicine. © 2017 International Society for Magnetic Resonance in Medicine.

  19. Identification and reduction of image artifacts in non-contrast-enhanced velocity-selective peripheral angiography at 3T.

    PubMed

    Shin, Taehoon; Qin, Qin; Park, Jang-Yeon; Crawford, Robert S; Rajagopalan, Sanjay

    2016-08-01

    To identify and reduce image artifacts in non-contrast-enhanced velocity-selective (VS) magnetization-prepared peripheral MR angiography (MRA) at 3T. To avoid signal loss in the arteries, double and quadruple refocused VS excitation pulse sequences were designed that were robust to a wide range of B0 and B1 offset. To suppress stripe artifact and background signal variation, we successively applied two VS preparations with excitation profiles shifted by half the period of the stripes. VS-MRA using single, double, and quadruple refocused VS preparations was tested in healthy subjects and a patient. In the regions of large B0 and B1 offsets, arterial signal loss was yielded by single refocused VS preparation, but was avoided with double or quadruple refocused preparations. Compared with single VS preparation, the two consecutive preparations with shifted excitation profiles substantially reduced the stripe artifact and background signal variation, as demonstrated by increased mean and decreased standard deviation of relative contrast-to-noise ratio. The proposed VS-MRA identified multilevel disease in the femoral arteries of the patient, as validated by digital subtraction angiography. Two multiple refocused VS magnetization preparations with shifted excitation profiles yield artifact-free peripheral angiograms at 3T. Magn Reson Med 76:466-477, 2016. © 2015 Wiley Periodicals, Inc. © 2015 Wiley Periodicals, Inc.

  20. Localized one-dimensional single voxel magnetic resonance spectroscopy without J coupling modulations.

    PubMed

    Lin, Yanqin; Lin, Liangjie; Wei, Zhiliang; Zhong, Jianhui; Chen, Zhong

    2016-12-01

    To acquire single voxel localized one-dimensional 1 H magnetic resonance spectroscopy (MRS) without J coupling modulations, free from amplitude and phase distortions. A pulse sequence, named PRESSIR, is developed for volume localized MRS without J modulations at arbitrary echo time (TE). The J coupling evolution is suppressed by the J-refocused module that uses a 90° pulse at the midpoint of a double spin echo. The localization performance of the PRESSIR sequence was tested with a two-compartment phantom. The proposed sequence shows similar voxel localization accuracy as PRESS. Both PRESSIR and PRESS sequences were performed on MRS brain phantom and pig brain tissue. PRESS spectra suffer from amplitude and phase distortions due to J modulations, especially under moderate and long TEs, while PRESSIR spectra are almost free from distortions. The PRESSIR sequence proposed herein enables the acquisition of single voxel in-phase MRS within a single scan. It allows an enhanced signal intensity of J coupling metabolites and reducing undesired broad resonances with short T2s while suppressing J modulations. Moreover, it provides an approach for direct measurement of nonoverlapping J coupling peaks and of transverse relaxation times T2s. Magn Reson Med 76:1661-1667, 2016. © 2015 International Society for Magnetic Resonance in Medicine. © 2015 International Society for Magnetic Resonance in Medicine.

  1. Effects of White Matter Microstructure on Phase and Susceptibility Maps

    PubMed Central

    Wharton, Samuel; Bowtell, Richard

    2015-01-01

    Purpose To investigate the effects on quantitative susceptibility mapping (QSM) and susceptibility tensor imaging (STI) of the frequency variation produced by the microstructure of white matter (WM). Methods The frequency offsets in a WM tissue sample that are not explained by the effect of bulk isotropic or anisotropic magnetic susceptibility, but rather result from the local microstructure, were characterized for the first time. QSM and STI were then applied to simulated frequency maps that were calculated using a digitized whole-brain, WM model formed from anatomical and diffusion tensor imaging data acquired from a volunteer. In this model, the magnitudes of the frequency contributions due to anisotropy and microstructure were derived from the results of the tissue experiments. Results The simulations suggest that the frequency contribution of microstructure is much larger than that due to bulk effects of anisotropic magnetic susceptibility. In QSM, the microstructure contribution introduced artificial WM heterogeneity. For the STI processing, the microstructure contribution caused the susceptibility anisotropy to be significantly overestimated. Conclusion Microstructure-related phase offsets in WM yield artifacts in the calculated susceptibility maps. If susceptibility mapping is to become a robust MRI technique, further research should be carried out to reduce the confounding effects of microstructure-related frequency contributions. Magn Reson Med 73:1258–1269, 2015. © 2014 Wiley Periodicals, Inc. PMID:24619643

  2. Efficient parallel reconstruction for high resolution multishot spiral diffusion data with low rank constraint.

    PubMed

    Liao, Congyu; Chen, Ying; Cao, Xiaozhi; Chen, Song; He, Hongjian; Mani, Merry; Jacob, Mathews; Magnotta, Vincent; Zhong, Jianhui

    2017-03-01

    To propose a novel reconstruction method using parallel imaging with low rank constraint to accelerate high resolution multishot spiral diffusion imaging. The undersampled high resolution diffusion data were reconstructed based on a low rank (LR) constraint using similarities between the data of different interleaves from a multishot spiral acquisition. The self-navigated phase compensation using the low resolution phase data in the center of k-space was applied to correct shot-to-shot phase variations induced by motion artifacts. The low rank reconstruction was combined with sensitivity encoding (SENSE) for further acceleration. The efficiency of the proposed joint reconstruction framework, dubbed LR-SENSE, was evaluated through error quantifications and compared with ℓ1 regularized compressed sensing method and conventional iterative SENSE method using the same datasets. It was shown that with a same acceleration factor, the proposed LR-SENSE method had the smallest normalized sum-of-squares errors among all the compared methods in all diffusion weighted images and DTI-derived index maps, when evaluated with different acceleration factors (R = 2, 3, 4) and for all the acquired diffusion directions. Robust high resolution diffusion weighted image can be efficiently reconstructed from highly undersampled multishot spiral data with the proposed LR-SENSE method. Magn Reson Med 77:1359-1366, 2017. © 2016 International Society for Magnetic Resonance in Medicine. © 2016 International Society for Magnetic Resonance in Medicine.

  3. Real-time distortion correction of spiral and echo planar images using the gradient system impulse response function.

    PubMed

    Campbell-Washburn, Adrienne E; Xue, Hui; Lederman, Robert J; Faranesh, Anthony Z; Hansen, Michael S

    2016-06-01

    MRI-guided interventions demand high frame rate imaging, making fast imaging techniques such as spiral imaging and echo planar imaging (EPI) appealing. In this study, we implemented a real-time distortion correction framework to enable the use of these fast acquisitions for interventional MRI. Distortions caused by gradient waveform inaccuracies were corrected using the gradient impulse response function (GIRF), which was measured by standard equipment and saved as a calibration file on the host computer. This file was used at runtime to calculate the predicted k-space trajectories for image reconstruction. Additionally, the off-resonance reconstruction frequency was modified in real time to interactively deblur spiral images. Real-time distortion correction for arbitrary image orientations was achieved in phantoms and healthy human volunteers. The GIRF-predicted k-space trajectories matched measured k-space trajectories closely for spiral imaging. Spiral and EPI image distortion was visibly improved using the GIRF-predicted trajectories. The GIRF calibration file showed no systematic drift in 4 months and was demonstrated to correct distortions after 30 min of continuous scanning despite gradient heating. Interactive off-resonance reconstruction was used to sharpen anatomical boundaries during continuous imaging. This real-time distortion correction framework will enable the use of these high frame rate imaging methods for MRI-guided interventions. Magn Reson Med 75:2278-2285, 2016. © 2015 Wiley Periodicals, Inc. © 2015 Wiley Periodicals, Inc.

  4. First-pass myocardial perfusion imaging with whole-heart coverage using L1-SPIRiT accelerated variable density spiral trajectories.

    PubMed

    Yang, Yang; Kramer, Christopher M; Shaw, Peter W; Meyer, Craig H; Salerno, Michael

    2016-11-01

    To design and evaluate two-dimensional (2D) L1-SPIRiT accelerated spiral pulse sequences for first-pass myocardial perfusion imaging with whole heart coverage capable of measuring eight slices at 2 mm in-plane resolution at heart rates up to 125 beats per minute (BPM). Combinations of five different spiral trajectories and four k-t sampling patterns were retrospectively simulated in 25 fully sampled datasets and reconstructed with L1-SPIRiT to determine the best combination of parameters. Two candidate sequences were prospectively evaluated in 34 human subjects to assess in vivo performance. A dual density broad transition spiral trajectory with either angularly uniform or golden angle in time k-t sampling pattern had the largest structural similarity and smallest root mean square error from the retrospective simulation, and the L1-SPIRiT reconstruction had well-preserved temporal dynamics. In vivo data demonstrated that both of the sampling patterns could produce high quality perfusion images with whole-heart coverage. First-pass myocardial perfusion imaging using accelerated spirals with optimized trajectory and k-t sampling pattern can produce high quality 2D perfusion images with whole-heart coverage at the heart rates up to 125 BPM. Magn Reson Med 76:1375-1387, 2016. © 2015 International Society for Magnetic Resonance in Medicine. © 2015 International Society for Magnetic Resonance in Medicine.

  5. Radial q-space sampling for DSI.

    PubMed

    Baete, Steven H; Yutzy, Stephen; Boada, Fernando E

    2016-09-01

    Diffusion spectrum imaging (DSI) has been shown to be an effective tool for noninvasively depicting the anatomical details of brain microstructure. Existing implementations of DSI sample the diffusion encoding space using a rectangular grid. Here we present a different implementation of DSI whereby a radially symmetric q-space sampling scheme for DSI is used to improve the angular resolution and accuracy of the reconstructed orientation distribution functions. Q-space is sampled by acquiring several q-space samples along a number of radial lines. Each of these radial lines in q-space is analytically connected to a value of the orientation distribution functions at the same angular location by the Fourier slice theorem. Computer simulations and in vivo brain results demonstrate that radial diffusion spectrum imaging correctly estimates the orientation distribution functions when moderately high b-values (4000 s/mm2) and number of q-space samples (236) are used. The nominal angular resolution of radial diffusion spectrum imaging depends on the number of radial lines used in the sampling scheme, and only weakly on the maximum b-value. In addition, the radial analytical reconstruction reduces truncation artifacts which affect Cartesian reconstructions. Hence, a radial acquisition of q-space can be favorable for DSI. Magn Reson Med 76:769-780, 2016. © 2015 Wiley Periodicals, Inc. © 2015 Wiley Periodicals, Inc.

  6. Multibreath alveolar oxygen tension imaging.

    PubMed

    Clapp, Justin; Hamedani, Hooman; Kadlecek, Stephen; Xin, Yi; Shaghaghi, Hoora; Siddiqui, Sarmad; Rossman, Milton D; Rizi, Rahim R

    2016-10-01

    This study tested the ability of a multibreath hyperpolarized HP (3) He MRI protocol to increase the accuracy of regional alveolar oxygen tension (PA O2 ) measurements by lessening the influence of gas-flow artifacts. Conventional single-breath PA O2 measurement has been susceptible to error induced by intervoxel gas flow, particularly when used to study subjects with moderate-to-severe chronic obstructive pulmonary disease (COPD). Both single-breath and multibreath PA O2 imaging schemes were implemented in seven human subjects (one healthy, three asymptomatic smokers, and three COPD). The number and location of voxels with nonphysiologic PA O2 values generated by intervoxel gas flow were compared between the two protocols. The multibreath scheme resulted in a significantly lower total percentage of nonphysiologic PA O2 values (6.0%) than the single-breath scheme (13.7%) (P = 0.006). PA O2 maps showed several patterns of gas-flow artifacts that were present in the single-breath protocol but mitigated by the multibreath approach. Multibreath imaging also allowed for the analysis of slow-filling areas that presented no signal after a single breath. A multibreath approach enhances the accuracy and completeness of noninvasive PA O2 measurement by significantly lessening the proportion of nonphysiologic values generated by intervoxel gas flow. Magn Reson Med 76:1092-1101, 2016. © 2015 Wiley Periodicals, Inc. © 2015 Wiley Periodicals, Inc.

  7. En la búsqueda de características en eyecciones coronales de masa que discriminen entre dos paradigmas físicos en modelos de ECMs

    NASA Astrophysics Data System (ADS)

    Paissan, G.; Stenborg, G.; Rovira, M.

    Se conocen tres diferentes fenómenos de gran escala que ocurren en la atmósfera solar, denominados eyecciones coronales de masa (ECMs), protuberancias eruptivas y grandes fulguraciones de dos bandas. Estos fenómenos están estrechamente relacionados y podrían ser distintas manifestaciones de un único proceso físico. Las ECMs son definidas como eyecciones de gran escala de masa y flujo magnético desde la baja corona al espacio interplanetario. Desde su descubrimiento en los '70, muchos modelos han sido propuestos para explicar su origen y evolución. La explicación física de las ECMs es un tema de debate intenso. No obstante, los modelos pueden sintetizarse en dos grandes grupos: 1) los modelos de inyección de flujo y 2) los modelos de almacenamiento y liberación. En este trabajo, se presentan los estudios realizados con una serie de eventos observados con el coronógrafo MICA (Mirror Coronograph for Argentina), el telescopio en H-alfa HASTA (H-alpha Solar Telescope for Argentina) y los coronógrafos C2 y C3 de la sonda SOHO (Solar and Heliospheric Observatory). Los eventos que pudieron ser identificados como ECMs son contrastados dentro del esquema de los dos paradigmas teóricos propuestos.

  8. Direct quantitative 13 C-filtered 1 H magnetic resonance imaging of PEGylated biomacromolecules in vivo.

    PubMed

    Alvares, Rohan D A; Lau, Justin Y C; Macdonald, Peter M; Cunningham, Charles H; Prosser, R Scott

    2017-04-01

    1 H MRI is an established diagnostic method that generally relies on detection of water. Imaging specific macromolecules is normally accomplished only indirectly through the use of paramagnetic tags, which alter the water signal in their vicinity. We demonstrate a new approach in which macromolecular constituents, such as proteins and drug delivery systems, are observed directly and quantitatively in vivo using 1 H MRI of 13 C-labeled poly(ethylene glycol) ( 13 C-PEG) tags. Molecular imaging of 13 C-PEG-labeled species was accomplished by incorporating a modified heteronuclear multiple quantum coherence filter into a gradient echo imaging sequence. We demonstrate the approach by monitoring the real-time distribution of 13 C-PEG and 13 C-PEGylated albumin injected into the hind leg of a mouse. Filtering the 1 H PEG signal through the directly coupled 13 C nuclei largely eliminates background water and fat signals, thus enabling the imaging of molecules using 1 H MRI. PEGylation is widely employed to enhance the performance of a multitude of macromolecular therapeutics and drug delivery systems, and 13 C-filtered 1 H MRI of 13 C-PEG thus offers the possibility of imaging and quantitating their distribution in living systems in real time. Magn Reson Med 77:1553-1561, 2017. © 2016 International Society for Magnetic Resonance in Medicine. © 2016 International Society for Magnetic Resonance in Medicine.

  9. Multi-scale graph-cut algorithm for efficient water-fat separation.

    PubMed

    Berglund, Johan; Skorpil, Mikael

    2017-09-01

    To improve the accuracy and robustness to noise in water-fat separation by unifying the multiscale and graph cut based approaches to B 0 -correction. A previously proposed water-fat separation algorithm that corrects for B 0 field inhomogeneity in 3D by a single quadratic pseudo-Boolean optimization (QPBO) graph cut was incorporated into a multi-scale framework, where field map solutions are propagated from coarse to fine scales for voxels that are not resolved by the graph cut. The accuracy of the single-scale and multi-scale QPBO algorithms was evaluated against benchmark reference datasets. The robustness to noise was evaluated by adding noise to the input data prior to water-fat separation. Both algorithms achieved the highest accuracy when compared with seven previously published methods, while computation times were acceptable for implementation in clinical routine. The multi-scale algorithm was more robust to noise than the single-scale algorithm, while causing only a small increase (+10%) of the reconstruction time. The proposed 3D multi-scale QPBO algorithm offers accurate water-fat separation, robustness to noise, and fast reconstruction. The software implementation is freely available to the research community. Magn Reson Med 78:941-949, 2017. © 2016 International Society for Magnetic Resonance in Medicine. © 2016 International Society for Magnetic Resonance in Medicine.

  10. Forecasting the quality of water-suppressed 1 H MR spectra based on a single-shot water scan.

    PubMed

    Kyathanahally, Sreenath P; Kreis, Roland

    2017-08-01

    To investigate whether an initial non-water-suppressed acquisition that provides information about the signal-to-noise ratio (SNR) and linewidth is enough to forecast the maximally achievable final spectral quality and thus inform the operator whether the foreseen number of averages and achieved field homogeneity is adequate. A large range of spectra with varying SNR and linewidth was simulated and fitted with popular fitting programs to determine the dependence of fitting errors on linewidth and SNR. A tool to forecast variance based on a single acquisition was developed and its performance evaluated on simulated and in vivo data obtained at 3 Tesla from various brain regions and acquisition settings. A strong correlation to real uncertainties in estimated metabolite contents was found for the forecast values and the Cramer-Rao lower bounds obtained from the water-suppressed spectra. It appears to be possible to forecast the best-case errors associated with specific metabolites to be found in model fits of water-suppressed spectra based on a single water scan. Thus, nonspecialist operators will be able to judge ahead of time whether the planned acquisition can possibly be of sufficient quality to answer the targeted clinical question or whether it needs more averages or improved shimming. Magn Reson Med 78:441-451, 2017. © 2016 International Society for Magnetic Resonance in Medicine. © 2016 International Society for Magnetic Resonance in Medicine.

  11. Hybrid MRI-Ultrasound acquisitions, and scannerless real-time imaging.

    PubMed

    Preiswerk, Frank; Toews, Matthew; Cheng, Cheng-Chieh; Chiou, Jr-Yuan George; Mei, Chang-Sheng; Schaefer, Lena F; Hoge, W Scott; Schwartz, Benjamin M; Panych, Lawrence P; Madore, Bruno

    2017-09-01

    To combine MRI, ultrasound, and computer science methodologies toward generating MRI contrast at the high frame rates of ultrasound, inside and even outside the MRI bore. A small transducer, held onto the abdomen with an adhesive bandage, collected ultrasound signals during MRI. Based on these ultrasound signals and their correlations with MRI, a machine-learning algorithm created synthetic MR images at frame rates up to 100 per second. In one particular implementation, volunteers were taken out of the MRI bore with the ultrasound sensor still in place, and MR images were generated on the basis of ultrasound signal and learned correlations alone in a "scannerless" manner. Hybrid ultrasound-MRI data were acquired in eight separate imaging sessions. Locations of liver features, in synthetic images, were compared with those from acquired images: The mean error was 1.0 pixel (2.1 mm), with best case 0.4 and worst case 4.1 pixels (in the presence of heavy coughing). For results from outside the bore, qualitative validation involved optically tracked ultrasound imaging with/without coughing. The proposed setup can generate an accurate stream of high-speed MR images, up to 100 frames per second, inside or even outside the MR bore. Magn Reson Med 78:897-908, 2017. © 2016 International Society for Magnetic Resonance in Medicine. © 2016 International Society for Magnetic Resonance in Medicine.

  12. Joint eigenvector estimation from mutually anisotropic tensors improves susceptibility tensor imaging of the brain, kidney, and heart.

    PubMed

    Dibb, Russell; Liu, Chunlei

    2017-06-01

    To develop a susceptibility-based MRI technique for probing microstructure and fiber architecture of magnetically anisotropic tissues-such as central nervous system white matter, renal tubules, and myocardial fibers-in three dimensions using susceptibility tensor imaging (STI) tools. STI can probe tissue microstructure, but is limited by reconstruction artifacts because of absent phase information outside the tissue and noise. STI accuracy may be improved by estimating a joint eigenvector from mutually anisotropic susceptibility and relaxation tensors. Gradient-recalled echo image data were simulated using a numerical phantom and acquired from the ex vivo mouse brain, kidney, and heart. Susceptibility tensor data were reconstructed using STI, regularized STI, and the proposed algorithm of mutually anisotropic and joint eigenvector STI (MAJESTI). Fiber map and tractography results from each technique were compared with diffusion tensor data. MAJESTI reduced the estimated susceptibility tensor orientation error by 30% in the phantom, 36% in brain white matter, 40% in the inner medulla of the kidney, and 45% in myocardium. This improved the continuity and consistency of susceptibility-based fiber tractography in each tissue. MAJESTI estimation of the susceptibility tensors yields lower orientation errors for susceptibility-based fiber mapping and tractography in the intact brain, kidney, and heart. Magn Reson Med 77:2331-2346, 2017. © 2016 International Society for Magnetic Resonance in Medicine. © 2016 International Society for Magnetic Resonance in Medicine.

  13. Diagnosis of Vein of Galen aneurysmal malformation using fetal MRI.

    PubMed

    Zhou, Li-Xia; Dong, Su-Zhen; Zhang, Ming-Feng

    2017-11-01

    To present three fetal vein of Galen aneurysmal malformations (VGAMs), which were diagnosed through magnetic resonance imaging (MRI), and highlight these cardiovascular findings. We retrospectively reviewed three fetuses with VGAM at 31, 32, and 33 weeks of gestation. Feeding arteries and draining veins were observed by MRI. Secondary changes in the brain and high-output heart failure caused by high blood flow in the lesion were evaluated. Two fetuses were born, and neonatal MRI was performed. One fetus was terminated. A characteristic dilated structure in the midline of the brain presented in each fetus. The arteriovenous fistula led to anatomical brain changes such as in the hydrocephalus, dilated feeding vessels (one or more), jugular vein, and/or superior vena cava. Substantial brachiocephalic vessel dilation was observed in two fetuses. Following parturition, one baby had neonatal asphyxia and sinus thrombosis, and MRI revealed hypoxic-ischemic encephalopathy. Cardiomegaly was detected in all three cases. With a large field of view, fetal MRI can observe brain VGAM, as well as the heart and affected large vessels. It can determine hydrocephalus, ischemia, intracranial hemorrhage, and sinus thrombosis. Providing such information on the infant's entire body can aid clinicians in determining the most appropriate treatment. 4 J. Magn. Reson. Imaging 2017;46:1535-1539. © 2016 International Society for Magnetic Resonance in Medicine.

  14. Deep learning approaches for detection and removal of ghosting artifacts in MR spectroscopy.

    PubMed

    Kyathanahally, Sreenath P; Döring, André; Kreis, Roland

    2018-09-01

    To make use of deep learning (DL) methods to detect and remove ghosting artifacts in clinical magnetic resonance spectra of human brain. Deep learning algorithms, including fully connected neural networks, deep-convolutional neural networks, and stacked what-where auto encoders, were implemented to detect and correct MR spectra containing spurious echo ghost signals. The DL methods were trained on a huge database of simulated spectra with and without ghosting artifacts that represent complex variations of ghost-ridden spectra, transformed to time-frequency spectrograms. The trained model was tested on simulated and in vivo spectra. The preliminary results for ghost detection are very promising, reaching almost 100% accuracy, and the DL ghost removal methods show potential in simulated and in vivo spectra, but need further refinement and quantitative testing. Ghosting artifacts in spectroscopy are problematic, as they superimpose with metabolites and lead to inaccurate quantification. Detection and removal of ghosting artifacts using traditional machine learning approaches with feature extraction/selection is difficult, as ghosts appear at different frequencies. Here, we show that DL methods perform extremely well for ghost detection if the spectra are treated as images in the form of time-frequency representations. Further optimization for in vivo spectra will hopefully confirm their "ghostbusting" capacity. Magn Reson Med 80:851-863, 2018. © 2018 International Society for Magnetic Resonance in Medicine. © 2018 International Society for Magnetic Resonance in Medicine.

  15. Variable density randomized stack of spirals (VDR-SoS) for compressive sensing MRI.

    PubMed

    Valvano, Giuseppe; Martini, Nicola; Landini, Luigi; Santarelli, Maria Filomena

    2016-07-01

    To develop a 3D sampling strategy based on a stack of variable density spirals for compressive sensing MRI. A random sampling pattern was obtained by rotating each spiral by a random angle and by delaying for few time steps the gradient waveforms of the different interleaves. A three-dimensional (3D) variable sampling density was obtained by designing different variable density spirals for each slice encoding. The proposed approach was tested with phantom simulations up to a five-fold undersampling factor. Fully sampled 3D dataset of a human knee, and of a human brain, were obtained from a healthy volunteer. The proposed approach was tested with off-line reconstructions of the knee dataset up to a four-fold acceleration and compared with other noncoherent trajectories. The proposed approach outperformed the standard stack of spirals for various undersampling factors. The level of coherence and the reconstruction quality of the proposed approach were similar to those of other trajectories that, however, require 3D gridding for the reconstruction. The variable density randomized stack of spirals (VDR-SoS) is an easily implementable trajectory that could represent a valid sampling strategy for 3D compressive sensing MRI. It guarantees low levels of coherence without requiring 3D gridding. Magn Reson Med 76:59-69, 2016. © 2015 Wiley Periodicals, Inc. © 2015 Wiley Periodicals, Inc.

  16. An MRI-compatible platform for one-dimensional motion management studies in MRI.

    PubMed

    Nofiele, Joris; Yuan, Qing; Kazem, Mohammad; Tatebe, Ken; Torres, Quinn; Sawant, Amit; Pedrosa, Ivan; Chopra, Rajiv

    2016-08-01

    Abdominal MRI remains challenging because of respiratory motion. Motion compensation strategies are difficult to compare clinically because of the variability across human subjects. The goal of this study was to evaluate a programmable system for one-dimensional motion management MRI research. A system comprised of a programmable motorized linear stage and computer was assembled and tested in the MRI environment. Tests of the mutual interference between the platform and a whole-body MRI were performed. Organ trajectories generated from a high-temporal resolution scan of a healthy volunteer were used in phantom tests to evaluate the effects of motion on image quality and quantitative MRI measurements. No interference between the motion platform and the MRI was observed, and reliable motion could be produced across a wide range of imaging conditions. Motion-related artifacts commensurate with motion amplitude, frequency, and waveform were observed. T2 measurement of a kidney lesion in an abdominal phantom showed that its value decreased by 67% with physiologic motion, but could be partially recovered with navigator-based motion-compensation. The motion platform can produce reliable linear motion within a whole-body MRI. The system can serve as a foundation for a research platform to investigate and develop motion management approaches for MRI. Magn Reson Med 76:702-712, 2016. © 2015 Wiley Periodicals, Inc. © 2015 Wiley Periodicals, Inc.

  17. Low eddy current RF shielding enclosure designs for 3T MR applications.

    PubMed

    Lee, Brian J; Watkins, Ronald D; Chang, Chen-Ming; Levin, Craig S

    2018-03-01

    Magnetic resonance-compatible medical devices operate within the MR environment while benefitting from the superior anatomic information of MRI. Avoiding electromagnetic interference between such instrumentation and the MR system is crucial. In this work, various shielding configurations for positron emission tomography (PET) detectors were studied and analyzed regarding radiofrequency (RF) shielding effectiveness and gradient-induced eddy current performances. However, the results of this work apply to shielding considerations for any MR-compatible devices. Six shielding enclosure configurations with various thicknesses, patterns, and materials were designed: solid and segmented copper, phosphor bronze mesh (PBM), and carbon fiber composite (CFC). A series of tests was performed on RF shielding effectiveness and the gradient-induced eddy current. For the shielding effectiveness, the solid copper with various thickness and PBM configurations yield significantly better shielding effectiveness (>15 dB) compared with CFC and segmented configurations. For the gradient-induced eddy current performance, the solid copper shielding configurations with different thicknesses showed significantly worse results, up to a factor of 3.89 dB, compared with the segmented copper, PBM, and the CFC configurations. We evaluated the RF shielding effectiveness and the gradient-induced eddy current artifacts of several shielding designs, and only the PBM showed positive outcomes for both aspects. Magn Reson Med 79:1745-1752, 2018. © 2017 International Society for Magnetic Resonance in Medicine. © 2017 International Society for Magnetic Resonance in Medicine.

  18. Pulseq: A rapid and hardware-independent pulse sequence prototyping framework.

    PubMed

    Layton, Kelvin J; Kroboth, Stefan; Jia, Feng; Littin, Sebastian; Yu, Huijun; Leupold, Jochen; Nielsen, Jon-Fredrik; Stöcker, Tony; Zaitsev, Maxim

    2017-04-01

    Implementing new magnetic resonance experiments, or sequences, often involves extensive programming on vendor-specific platforms, which can be time consuming and costly. This situation is exacerbated when research sequences need to be implemented on several platforms simultaneously, for example, at different field strengths. This work presents an alternative programming environment that is hardware-independent, open-source, and promotes rapid sequence prototyping. A novel file format is described to efficiently store the hardware events and timing information required for an MR pulse sequence. Platform-dependent interpreter modules convert the file to appropriate instructions to run the sequence on MR hardware. Sequences can be designed in high-level languages, such as MATLAB, or with a graphical interface. Spin physics simulation tools are incorporated into the framework, allowing for comparison between real and virtual experiments. Minimal effort is required to implement relatively advanced sequences using the tools provided. Sequences are executed on three different MR platforms, demonstrating the flexibility of the approach. A high-level, flexible and hardware-independent approach to sequence programming is ideal for the rapid development of new sequences. The framework is currently not suitable for large patient studies or routine scanning although this would be possible with deeper integration into existing workflows. Magn Reson Med 77:1544-1552, 2017. © 2016 International Society for Magnetic Resonance in Medicine. © 2016 International Society for Magnetic Resonance in Medicine.

  19. Parallel transmission pulse design with explicit control for the specific absorption rate in the presence of radiofrequency errors.

    PubMed

    Martin, Adrian; Schiavi, Emanuele; Eryaman, Yigitcan; Herraiz, Joaquin L; Gagoski, Borjan; Adalsteinsson, Elfar; Wald, Lawrence L; Guerin, Bastien

    2016-06-01

    A new framework for the design of parallel transmit (pTx) pulses is presented introducing constraints for local and global specific absorption rate (SAR) in the presence of errors in the radiofrequency (RF) transmit chain. The first step is the design of a pTx RF pulse with explicit constraints for global and local SAR. Then, the worst possible SAR associated with that pulse due to RF transmission errors ("worst-case SAR") is calculated. Finally, this information is used to re-calculate the pulse with lower SAR constraints, iterating this procedure until its worst-case SAR is within safety limits. Analysis of an actual pTx RF transmit chain revealed amplitude errors as high as 8% (20%) and phase errors above 3° (15°) for spokes (spiral) pulses. Simulations show that using the proposed framework, pulses can be designed with controlled "worst-case SAR" in the presence of errors of this magnitude at minor cost of the excitation profile quality. Our worst-case SAR-constrained pTx design strategy yields pulses with local and global SAR within the safety limits even in the presence of RF transmission errors. This strategy is a natural way to incorporate SAR safety factors in the design of pTx pulses. Magn Reson Med 75:2493-2504, 2016. © 2015 Wiley Periodicals, Inc. © 2015 Wiley Periodicals, Inc.

  20. Signal-domain optimization metrics for MPRAGE RF pulse design in parallel transmission at 7 tesla.

    PubMed

    Gras, V; Vignaud, A; Mauconduit, F; Luong, M; Amadon, A; Le Bihan, D; Boulant, N

    2016-11-01

    Standard radiofrequency pulse design strategies focus on minimizing the deviation of the flip angle from a target value, which is sufficient but not necessary for signal homogeneity. An alternative approach, based directly on the signal, here is proposed for the MPRAGE sequence, and is developed in the parallel transmission framework with the use of the k T -points parametrization. The flip angle-homogenizing and the proposed methods were investigated numerically under explicit power and specific absorption rate constraints and tested experimentally in vivo on a 7 T parallel transmission system enabling real time local specific absorption rate monitoring. Radiofrequency pulse performance was assessed by a careful analysis of the signal and contrast between white and gray matter. Despite a slight reduction of the flip angle uniformity, an improved signal and contrast homogeneity with a significant reduction of the specific absorption rate was achieved with the proposed metric in comparison with standard pulse designs. The proposed joint optimization of the inversion and excitation pulses enables significant reduction of the specific absorption rate in the MPRAGE sequence while preserving image quality. The work reported thus unveils a possible direction to increase the potential of ultra-high field MRI and parallel transmission. Magn Reson Med 76:1431-1442, 2016. © 2015 International Society for Magnetic Resonance in Medicine. © 2015 International Society for Magnetic Resonance in Medicine.

  1. Advancing RF pulse design using an open-competition format: Report from the 2015 ISMRM challenge.

    PubMed

    Grissom, William A; Setsompop, Kawin; Hurley, Samuel A; Tsao, Jeffrey; Velikina, Julia V; Samsonov, Alexey A

    2017-10-01

    To advance the best solutions to two important RF pulse design problems with an open head-to-head competition. Two sub-challenges were formulated in which contestants competed to design the shortest simultaneous multislice (SMS) refocusing pulses and slice-selective parallel transmission (pTx) excitation pulses, subject to realistic hardware and safety constraints. Short refocusing pulses are needed for spin echo SMS imaging at high multiband factors, and short slice-selective pTx pulses are needed for multislice imaging in ultra-high field MRI. Each sub-challenge comprised two phases, in which the first phase posed problems with a low barrier of entry, and the second phase encouraged solutions that performed well in general. The Challenge ran from October 2015 to May 2016. The pTx Challenge winners developed a spokes pulse design method that combined variable-rate selective excitation with an efficient method to enforce SAR constraints, which achieved 10.6 times shorter pulse durations than conventional approaches. The SMS Challenge winners developed a time-optimal control multiband pulse design algorithm that achieved 5.1 times shorter pulse durations than conventional approaches. The Challenge led to rapid step improvements in solutions to significant problems in RF excitation for SMS imaging and ultra-high field MRI. Magn Reson Med 78:1352-1361, 2017. © 2016 International Society for Magnetic Resonance in Medicine. © 2016 International Society for Magnetic Resonance in Medicine.

  2. MR-based detection of individual histotripsy bubble clouds formed in tissues and phantoms.

    PubMed

    Allen, Steven P; Hernandez-Garcia, Luis; Cain, Charles A; Hall, Timothy L

    2016-11-01

    To demonstrate that MR sequences can detect individual histotripsy bubble clouds formed inside intact tissues. A line-scan and an EPI sequence were sensitized to histotripsy by inserting a bipolar gradient whose lobes bracketed the lifespan of a histotripsy bubble cloud. Using a 7 Tesla, small-bore scanner, these sequences monitored histotripsy clouds formed in an agar phantom and in vitro porcine liver and brain. The bipolar gradients were adjusted to apply phase with k-space frequencies of 10, 300 or 400 cm -1 . Acoustic pressure amplitude was also varied. Cavitation was simultaneously monitored using a passive cavitation detection system. Each image captured local signal loss specific to an individual bubble cloud. In the agar phantom, this signal loss appeared only when the transducer output exceeded the cavitation threshold pressure. In tissues, bubble clouds were immediately detected when the gradients created phase with k-space frequencies of 300 and 400 cm -1 . When the gradients created phase with a k-space frequency of 10 cm -1 , individual bubble clouds were not detectable until many acoustic pulses had been applied to the tissue. Cavitation-sensitive MR-sequences can detect single histotripsy bubble clouds formed in biologic tissue. Detection is influenced by the sensitizing gradients and treatment history. Magn Reson Med 76:1486-1493, 2016. © 2015 International Society for Magnetic Resonance in Medicine. © 2015 International Society for Magnetic Resonance in Medicine.

  3. Bayesian estimation of multicomponent relaxation parameters in magnetic resonance fingerprinting.

    PubMed

    McGivney, Debra; Deshmane, Anagha; Jiang, Yun; Ma, Dan; Badve, Chaitra; Sloan, Andrew; Gulani, Vikas; Griswold, Mark

    2018-07-01

    To estimate multiple components within a single voxel in magnetic resonance fingerprinting when the number and types of tissues comprising the voxel are not known a priori. Multiple tissue components within a single voxel are potentially separable with magnetic resonance fingerprinting as a result of differences in signal evolutions of each component. The Bayesian framework for inverse problems provides a natural and flexible setting for solving this problem when the tissue composition per voxel is unknown. Assuming that only a few entries from the dictionary contribute to a mixed signal, sparsity-promoting priors can be placed upon the solution. An iterative algorithm is applied to compute the maximum a posteriori estimator of the posterior probability density to determine the magnetic resonance fingerprinting dictionary entries that contribute most significantly to mixed or pure voxels. Simulation results show that the algorithm is robust in finding the component tissues of mixed voxels. Preliminary in vivo data confirm this result, and show good agreement in voxels containing pure tissue. The Bayesian framework and algorithm shown provide accurate solutions for the partial-volume problem in magnetic resonance fingerprinting. The flexibility of the method will allow further study into different priors and hyperpriors that can be applied in the model. Magn Reson Med 80:159-170, 2018. © 2017 International Society for Magnetic Resonance in Medicine. © 2017 International Society for Magnetic Resonance in Medicine.

  4. MR fingerprinting using the quick echo splitting NMR imaging technique.

    PubMed

    Jiang, Yun; Ma, Dan; Jerecic, Renate; Duerk, Jeffrey; Seiberlich, Nicole; Gulani, Vikas; Griswold, Mark A

    2017-03-01

    The purpose of the study is to develop a quantitative method for the relaxation properties with a reduced radio frequency (RF) power deposition by combining magnetic resonance fingerprinting (MRF) technique with quick echo splitting NMR imaging technique (QUEST). A QUEST-based MRF sequence was implemented to acquire high-order echoes by increasing the gaps between RF pulses. Bloch simulations were used to calculate a dictionary containing the range of physically plausible signal evolutions using a range of T 1 and T 2 values based on the pulse sequence. MRF-QUEST was evaluated by comparing to the results of spin-echo methods. The specific absorption rate (SAR) of MRF-QUEST was compared with the clinically available methods. MRF-QUEST quantifies the relaxation properties with good accuracy at the estimated head SAR of 0.03 W/kg. T 1 and T 2 values estimated by MRF-QUEST are in good agreement with the traditional methods. The combination of the MRF and the QUEST provides an accurate quantification of T 1 and T 2 simultaneously with reduced RF power deposition. The resulting lower SAR may provide a new acquisition strategy for MRF when RF energy deposition is problematic. Magn Reson Med 77:979-988, 2017. © 2016 International Society for Magnetic Resonance in Medicine. © 2016 International Society for Magnetic Resonance in Medicine.

  5. Robust sliding-window reconstruction for Accelerating the acquisition of MR fingerprinting.

    PubMed

    Cao, Xiaozhi; Liao, Congyu; Wang, Zhixing; Chen, Ying; Ye, Huihui; He, Hongjian; Zhong, Jianhui

    2017-10-01

    To develop a method for accelerated and robust MR fingerprinting (MRF) with improved image reconstruction and parameter matching processes. A sliding-window (SW) strategy was applied to MRF, in which signal and dictionary matching was conducted between fingerprints consisting of mixed-contrast image series reconstructed from consecutive data frames segmented by a sliding window, and a precalculated mixed-contrast dictionary. The effectiveness and performance of this new method, dubbed SW-MRF, was evaluated in both phantom and in vivo. Error quantifications were conducted on results obtained with various settings of SW reconstruction parameters. Compared with the original MRF strategy, the results of both phantom and in vivo experiments demonstrate that the proposed SW-MRF strategy either provided similar accuracy with reduced acquisition time, or improved accuracy with equal acquisition time. Parametric maps of T 1 , T 2 , and proton density of comparable quality could be achieved with a two-fold or more reduction in acquisition time. The effect of sliding-window width on dictionary sensitivity was also estimated. The novel SW-MRF recovers high quality image frames from highly undersampled MRF data, which enables more robust dictionary matching with reduced numbers of data frames. This time efficiency may facilitate MRF applications in time-critical clinical settings. Magn Reson Med 78:1579-1588, 2017. © 2016 International Society for Magnetic Resonance in Medicine. © 2016 International Society for Magnetic Resonance in Medicine.

  6. Low rank alternating direction method of multipliers reconstruction for MR fingerprinting.

    PubMed

    Assländer, Jakob; Cloos, Martijn A; Knoll, Florian; Sodickson, Daniel K; Hennig, Jürgen; Lattanzi, Riccardo

    2018-01-01

    The proposed reconstruction framework addresses the reconstruction accuracy, noise propagation and computation time for magnetic resonance fingerprinting. Based on a singular value decomposition of the signal evolution, magnetic resonance fingerprinting is formulated as a low rank (LR) inverse problem in which one image is reconstructed for each singular value under consideration. This LR approximation of the signal evolution reduces the computational burden by reducing the number of Fourier transformations. Also, the LR approximation improves the conditioning of the problem, which is further improved by extending the LR inverse problem to an augmented Lagrangian that is solved by the alternating direction method of multipliers. The root mean square error and the noise propagation are analyzed in simulations. For verification, in vivo examples are provided. The proposed LR alternating direction method of multipliers approach shows a reduced root mean square error compared to the original fingerprinting reconstruction, to a LR approximation alone and to an alternating direction method of multipliers approach without a LR approximation. Incorporating sensitivity encoding allows for further artifact reduction. The proposed reconstruction provides robust convergence, reduced computational burden and improved image quality compared to other magnetic resonance fingerprinting reconstruction approaches evaluated in this study. Magn Reson Med 79:83-96, 2018. © 2017 International Society for Magnetic Resonance in Medicine. © 2017 International Society for Magnetic Resonance in Medicine.

  7. Multiscale reconstruction for MR fingerprinting.

    PubMed

    Pierre, Eric Y; Ma, Dan; Chen, Yong; Badve, Chaitra; Griswold, Mark A

    2016-06-01

    To reduce the acquisition time needed to obtain reliable parametric maps with Magnetic Resonance Fingerprinting. An iterative-denoising algorithm is initialized by reconstructing the MRF image series at low image resolution. For subsequent iterations, the method enforces pixel-wise fidelity to the best-matching dictionary template then enforces fidelity to the acquired data at slightly higher spatial resolution. After convergence, parametric maps with desirable spatial resolution are obtained through template matching of the final image series. The proposed method was evaluated on phantom and in vivo data using the highly undersampled, variable-density spiral trajectory and compared with the original MRF method. The benefits of additional sparsity constraints were also evaluated. When available, gold standard parameter maps were used to quantify the performance of each method. The proposed approach allowed convergence to accurate parametric maps with as few as 300 time points of acquisition, as compared to 1000 in the original MRF work. Simultaneous quantification of T1, T2, proton density (PD), and B0 field variations in the brain was achieved in vivo for a 256 × 256 matrix for a total acquisition time of 10.2 s, representing a three-fold reduction in acquisition time. The proposed iterative multiscale reconstruction reliably increases MRF acquisition speed and accuracy. Magn Reson Med 75:2481-2492, 2016. © 2015 Wiley Periodicals, Inc. © 2015 Wiley Periodicals, Inc.

  8. Low rank approximation methods for MR fingerprinting with large scale dictionaries.

    PubMed

    Yang, Mingrui; Ma, Dan; Jiang, Yun; Hamilton, Jesse; Seiberlich, Nicole; Griswold, Mark A; McGivney, Debra

    2018-04-01

    This work proposes new low rank approximation approaches with significant memory savings for large scale MR fingerprinting (MRF) problems. We introduce a compressed MRF with randomized singular value decomposition method to significantly reduce the memory requirement for calculating a low rank approximation of large sized MRF dictionaries. We further relax this requirement by exploiting the structures of MRF dictionaries in the randomized singular value decomposition space and fitting them to low-degree polynomials to generate high resolution MRF parameter maps. In vivo 1.5T and 3T brain scan data are used to validate the approaches. T 1 , T 2 , and off-resonance maps are in good agreement with that of the standard MRF approach. Moreover, the memory savings is up to 1000 times for the MRF-fast imaging with steady-state precession sequence and more than 15 times for the MRF-balanced, steady-state free precession sequence. The proposed compressed MRF with randomized singular value decomposition and dictionary fitting methods are memory efficient low rank approximation methods, which can benefit the usage of MRF in clinical settings. They also have great potentials in large scale MRF problems, such as problems considering multi-component MRF parameters or high resolution in the parameter space. Magn Reson Med 79:2392-2400, 2018. © 2017 International Society for Magnetic Resonance in Medicine. © 2017 International Society for Magnetic Resonance in Medicine.

  9. 30-Second bound and pore water concentration mapping of cortical bone using 2D UTE with optimized half-pulses.

    PubMed

    Manhard, Mary Kate; Harkins, Kevin D; Gochberg, Daniel F; Nyman, Jeffry S; Does, Mark D

    2017-03-01

    MRI of cortical bone has the potential to offer new information about fracture risk. Current methods are typically performed with 3D acquisitions, which suffer from long scan times and are generally limited to extremities. This work proposes using 2D UTE with half pulses for quantitatively mapping bound and pore water in cortical bone. Half-pulse 2D UTE methods were implemented on a 3T Philips Achieva scanner using an optimized slice-select gradient waveform, with preparation pulses to selectively image bound or pore water. The 2D methods were quantitatively compared with previously implemented 3D methods in the tibia in five volunteers. The mean difference between bound and pore water concentration acquired from 3D and 2D sequences was 0.6 and 0.9 mol 1 H/L bone (3 and 12%, respectively). While 2D pore water methods tended to slightly overestimate concentrations relative to 3D methods, differences were less than scan-rescan uncertainty and expected differences between healthy and fracture-prone bones. Quantitative bound and pore water concentration mapping in cortical bone can be accelerated by 2 orders of magnitude using 2D protocols with optimized half-pulse excitation. Magn Reson Med 77:945-950, 2017. © 2017 International Society for Magnetic Resonance in Medicine. © 2017 International Society for Magnetic Resonance in Medicine.

  10. Presence of time-dependent diffusion in the brachial plexus.

    PubMed

    Mahbub, Zaid B; Peters, Andrew M; Gowland, Penny A

    2018-02-01

    This work describes the development of a method to measure the variation of apparent diffusion coefficient (ADC) with diffusion time (Δ) in the brachial plexus, as a potential method of probing microstructure. Diffusion-weighted MRI with body signal suppression was used to highlight the nerves from surrounding tissues, and sequence parameters were optimized for sensitivity to change with diffusion time. A porous media-restricted diffusion model based on the Latour-Mitra equation was fitted to the diffusion time-dependent ADC data from the brachial plexus nerves and cord. The ADC was observed to reduce at long diffusion times, confirming that diffusion was restricted in the nerves and cord in healthy subjects. T2 of the nerves was measured to be 80 ± 5 ms, the diffusion coefficient was found to vary from (1.5 ± 0.1) × 10 -3 mm 2 /s at a diffusion time of 18.3 ms to (1.0 ± 0.2) × 10 -3 mm 2 /s at a diffusion time of 81.3 ms. A novel method of probing restricted diffusion in the brachial plexus was developed. Resulting parameters were comparable with values obtained previously on biological systems. Magn Reson Med 79:789-795, 2018. © 2017 International Society for Magnetic Resonance in Medicine. © 2017 International Society for Magnetic Resonance in Medicine.

  11. Quantitative susceptibility mapping: Report from the 2016 reconstruction challenge.

    PubMed

    Langkammer, Christian; Schweser, Ferdinand; Shmueli, Karin; Kames, Christian; Li, Xu; Guo, Li; Milovic, Carlos; Kim, Jinsuh; Wei, Hongjiang; Bredies, Kristian; Buch, Sagar; Guo, Yihao; Liu, Zhe; Meineke, Jakob; Rauscher, Alexander; Marques, José P; Bilgic, Berkin

    2018-03-01

    The aim of the 2016 quantitative susceptibility mapping (QSM) reconstruction challenge was to test the ability of various QSM algorithms to recover the underlying susceptibility from phase data faithfully. Gradient-echo images of a healthy volunteer acquired at 3T in a single orientation with 1.06 mm isotropic resolution. A reference susceptibility map was provided, which was computed using the susceptibility tensor imaging algorithm on data acquired at 12 head orientations. Susceptibility maps calculated from the single orientation data were compared against the reference susceptibility map. Deviations were quantified using the following metrics: root mean squared error (RMSE), structure similarity index (SSIM), high-frequency error norm (HFEN), and the error in selected white and gray matter regions. Twenty-seven submissions were evaluated. Most of the best scoring approaches estimated the spatial frequency content in the ill-conditioned domain of the dipole kernel using compressed sensing strategies. The top 10 maps in each category had similar error metrics but substantially different visual appearance. Because QSM algorithms were optimized to minimize error metrics, the resulting susceptibility maps suffered from over-smoothing and conspicuity loss in fine features such as vessels. As such, the challenge highlighted the need for better numerical image quality criteria. Magn Reson Med 79:1661-1673, 2018. © 2017 International Society for Magnetic Resonance in Medicine. © 2017 International Society for Magnetic Resonance in Medicine.

  12. Correlation distance dependence of the resonance frequency of intermolecular zero quantum coherences and its implication for MR thermometry.

    PubMed

    Zhang, Le; McCallister, Andrew; Koshlap, Karl M; Branca, Rosa Tamara

    2018-03-01

    Because the resonance frequency of water-fat intermolecular zero-quantum coherences (iZQCs) reflects the water-fat frequency separation at the microscopic scale, these frequencies have been proposed and used as a mean to obtain more accurate temperature information. The purpose of this work was to investigate the dependence of the water-fat iZQC resonance frequency on sample microstructure and on the specific choice of the correlation distance. The effect of water-fat susceptibility gradients on the water-methylene iZQC resonance frequency was first computed and then measured for different water-fat emulsions and for a mixture of porcine muscle and fat. Similar measurements were also performed for mixed heteronuclear spin systems. A strong dependence of the iZQC resonance frequency on the sample microstructure and on the specific choice of the correlation distance was found for spin systems like water and fat that do not mix, but not for spin systems that mix at the molecular level. Because water and fat spins do not mix at the molecular level, the water-fat iZQC resonance frequency and its temperature coefficient are not only affected by sample microstructure but also by the specific choice of the correlation distance. Magn Reson Med 79:1429-1438, 2018. © 2017 International Society for Magnetic Resonance in Medicine. © 2017 International Society for Magnetic Resonance in Medicine.

  13. Spin-locking versus chemical exchange saturation transfer MRI for investigating chemical exchange process between water and labile metabolite protons.

    PubMed

    Jin, Tao; Autio, Joonas; Obata, Takayuki; Kim, Seong-Gi

    2011-05-01

    Chemical exchange saturation transfer (CEST) and spin-locking (SL) experiments were both able to probe the exchange process between protons of nonequivalent chemical environments. To compare the characteristics of the CEST and SL approaches in the study of chemical exchange effects, we performed CEST and SL experiments at varied pH and concentrated metabolite phantoms with exchangeable amide, amine, and hydroxyl protons at 9.4 T. Our results show that: (i) on-resonance SL is most sensitive to chemical exchanges in the intermediate-exchange regime and is able to detect hydroxyl and amine protons on a millimolar concentration scale. Off-resonance SL and CEST approaches are sensitive to slow-exchanging protons when an optimal SL or saturation pulse power matches the exchanging rate, respectively. (ii) Offset frequency-dependent SL and CEST spectra are very similar and can be explained well with an SL model recently developed by Trott and Palmer (J Magn Reson 2002;154:157-160). (iii) The exchange rate and population of metabolite protons can be determined from offset-dependent SL or CEST spectra or from on-resonance SL relaxation dispersion measurements. (iv) The asymmetry of the magnetization transfer ratio (MTR(asym)) is highly dependent on the choice of saturation pulse power. In the intermediate-exchange regime, MTR(asym) becomes complicated and should be interpreted with care. Copyright © 2010 Wiley-Liss, Inc.

  14. Monitoring of tissue modification with optical coherence tomography

    NASA Astrophysics Data System (ADS)

    Zhang, Wei; Luo, Qingming; Yao, Lei; Cheng, Haiying; Zeng, Shaoqun

    2002-04-01

    An experimental monitoring of tissue modification of in vitro and in vivo rabbit dura mater with administration of osmotical agents, 40% glucose solution and glycerol, using optical coherence tomography was presented. The preliminary results of experimental study of influence of osmotical liquids (glucose solutions, glycerol) of rabbit dura mater were reported. The significant decreasing of the light from surface and increasing of the light from the deep of dura mater under action of osmotical solutions and the increasing of OCT imaging depth were demonstrated. Experiments showed that administration of osmolytes to dura mater allowed for effective and temporary control of its optical characteristics, which made dura mater more transparent, increased the ability of light penetrating the tissue, and consequently improved the optical imaging depth. It is a significant study, which can improve penetration of optical imaging of cerebral function and acquire more information of the deep brain tissue.

  15. Corrigendum to "Matrix-algebra-based calculations of the time evolution of the binary spin-bath model for magnetization transfer" [J. Magn. Reson. 230 (2013) 88-97

    NASA Astrophysics Data System (ADS)

    Müller, Dirk K.; Pampel, André; Möller, Harald E.

    2015-12-01

    In the print version of this article initially published, reference to a funding source was missing. The following information should be added to the Acknowledgements section: This work was funded (in part) by the Helmholtz Alliance ICEMED-Imaging and Curing Environmental Metabolic Diseases, through the Initiative and Networking Fund of the Helmholtz Association.

  16. Efficient implementation of the continuous-time hybridization expansion quantum impurity solver

    NASA Astrophysics Data System (ADS)

    Hafermann, Hartmut; Werner, Philipp; Gull, Emanuel

    2013-04-01

    , P. Dayal, A. Feiguin, S. Fuchs, L. Gamper, E. Gull, S. Gürtler, A. Honecker, R. Igarashi, M. Körner, A. Kozhevnikov, A. Láuchli, S. Manmana, M. Matsumoto, I. McCulloch, F. Michel, R. Noack, G. Pawlowski, L. Pollet, T. Pruschke, U. Schollwöck, S. Todo, S. Trebst, M. Troyer, P. Werner and S. Wessel, J. Magn. Magn. Mater. 310, 1187 (2007), proceedings of the 17th International Conference on Magnetism The International Conference on Magnetism. C. L. Lawson, R. J. Hanson, D. R. Kincaid, and F. T. Krogh, ACM Transactions on Mathematical Software 5, 324 (1979). L. S. Blackford, J. Demmel, I. Du, G. Henry, M. Heroux, L. Kaufman, A. Lumsdaine, A. Petitet, and R. C. Whaley, ACM Trans. Math. Softw. 28, 135 (2002). E. Anderson, Z. Bai, C. Bischof, S. Blackford, J. Demmel, J. Dongarra, J. Du Croz, A. Greenbaum, S. Hammarling, A. McKenney, and D. Sorensen, LAPACK Users’ Guide, 3rd ed. (Society for Industrial and Applied Mathematics, Philadelphia, PA, 1999). The HDF Group, Hierarchical data format version 5, http://www.hdfgroup.org/HDF5 (2000-2010). E. Gull, A. J. Millis, A. I. Lichtenstein, A. N. Rubtsov, M. Troyer and P. Werner, Rev. Mod. Phys. 83, 349 (2011).

  17. The Role of Microstructural Variability on the Very High-Cycle Fatigue Behavior of Discontinuously-Reinforced Aluminum Metal Matrix Composites using Ultrasonic Fatigue (Preprint)

    DTIC Science & Technology

    2008-05-01

    controlled processing. Bhanu-Prasad et al .37 conducted a systematic study of PM-processed 2124/SiC/30p aluminum composites 4 5 in which matrix alloy...Mater., 27, 173-178. [5] Wang A, Rack HJ (1991). Transition wear behavior of SiC-particulate- and SiC- whisker-reinforced 7091 Al metal matrix...modeling of particle distribution effects on fatigue in Al -SiCp composites. Mater. Sci. Eng. A, Struct. Mater. Prop. Microstruct. Process., 300, 113-124

  18. Modélisation magnétique de la suture ophiolitique de Bou Azzer El Graara (Anti-Atlas central, Maroc). Implications sur la reconstitution géodynamique panafricaine

    NASA Astrophysics Data System (ADS)

    Soulaimani, Abderrahmane; Jaffal, Mohammed; Maacha, Lhou; Kchikach, Azzouz; Najine, Abdessamad; Saidi, Abdellatif

    2006-02-01

    Aeromagnetic data of the Anti-Atlas Mountains show an important magnetic anomaly along the 'Major Anti-Atlas Fault', produced by different mafic and ultramafic rocks of a Neoproterozoic ophiolite complex. The magnetic modelling of Bou Azzer-El Graara ophiolitic suture shows a deep-seated anomaly through the upper continental crust corresponding to a north-dipping subduction. The polarity of the Pan-African subduction in the Anti-Atlas is therefore compatible with the contemporaneous Pan-African orogenic belts, where polarity of subduction dipped away from the West African Craton during the amalgamation of Western Gondwana. To cite this article: A. Soulaimani et al., C. R. Geoscience 338 (2006).

  19. The Remarkable History Of Hypnosis In New Orleans (Société Du Magnétisme De La Nouvelle Orléans): A Tribute to Dabney Ewin.

    PubMed

    Tramontana, Joseph

    2016-01-01

    Dr. Dabney Ewin was a major factor in the revitalization of the New Orleans Society for Clinical Hypnosis (NOSCH) after it had been dormant for many years. This article briefly presents the fascinating history of the society as a tribute to Dr. Ewin, a remarkable physician.

  20. Meninges of the brain (image)

    MedlinePlus

    ... covered by connective tissue layers collectively called the meninges. Consisting of the pia mater (closest to the ... the dura mater (farthest from the CNS), the meninges also support blood vessels and contain cerebrospinal fluid. ...

  1. Meninges of the spine (image)

    MedlinePlus

    ... by 3 connective tissue layers collectively called the meninges. Consisting of the pia mater (closest to the ... the dura mater (farthest from the CNS), the meninges also support blood vessels and contain cerebrospinal fluid. ...

  2. Primal-dual and forward gradient implementation for quantitative susceptibility mapping.

    PubMed

    Kee, Youngwook; Deh, Kofi; Dimov, Alexey; Spincemaille, Pascal; Wang, Yi

    2017-12-01

    To investigate the computational aspects of the prior term in quantitative susceptibility mapping (QSM) by (i) comparing the Gauss-Newton conjugate gradient (GNCG) algorithm that uses numerical conditioning (ie, modifies the prior term) with a primal-dual (PD) formulation that avoids this, and (ii) carrying out a comparison between a central and forward difference scheme for the discretization of the prior term. A spatially continuous formulation of the regularized QSM inversion problem and its PD formulation were derived. The Chambolle-Pock algorithm for PD was implemented and its convergence behavior was compared with that of GNCG for the original QSM. Forward and central difference schemes were compared in terms of the presence of checkerboard artifacts. All methods were tested and validated on a gadolinium phantom, ex vivo brain blocks, and in vivo brain MRI data with respect to COSMOS. The PD approach provided a faster convergence rate than GNCG. The GNCG convergence rate slowed considerably with smaller (more accurate) values of the conditioning parameter. Using a forward difference suppressed the checkerboard artifacts in QSM, as compared with the central difference. The accuracy of PD and GNCG were validated based on excellent correlation with COSMOS. The PD approach with forward difference for the gradient showed improved convergence and accuracy over the GNCG method using central difference. Magn Reson Med 78:2416-2427, 2017. © 2017 International Society for Magnetic Resonance in Medicine. © 2017 International Society for Magnetic Resonance in Medicine.

  3. Transverse slot antennas for high field MRI

    PubMed Central

    Lattanzi, Riccardo; Lakshmanan, Karthik; Brown, Ryan; Deniz, Cem M.; Sodickson, Daniel K.; Collins, Christopher M.

    2018-01-01

    Purpose Introduce a novel coil design using an electrically long transversely oriented slot in a conductive sheet. Theory and Methods Theoretical considerations, numerical simulations, and experimental measurements are presented for transverse slot antennas as compared with electric dipole antennas. Results Simulations show improved central and average transmit and receive efficiency, as well as larger coverage in the transverse plane, for a single slot as compared to a single dipole element. Experiments on a body phantom confirm the simulation results for a slot antenna relative to a dipole, demonstrating a large region of relatively high sensitivity and homogeneity. Images in a human subject also show a large imaging volume for a single slot and six slot antenna array. High central transmit efficiency was observed for slot arrays relative to dipole arrays. Conclusion Transverse slots can exhibit improved sensitivity and larger field of view compared with traditional conductive dipoles. Simulations and experiments indicate high potential for slot antennas in high field MRI. Magn Reson Med 80:1233–1242, 2018. © 2018 The Authors Magnetic Resonance in Medicine published by Wiley Periodicals, Inc. on behalf of International Society for Magnetic Resonance in Medicine. This is an open access article under the terms of the Creative Commons Attribution NonCommercial License, which permits use, distribution and reproduction in any medium, provided the original work is properly cited and is not used for commercial purposes. PMID:29388250

  4. Experimental implementation of array-compressed parallel transmission at 7 tesla.

    PubMed

    Yan, Xinqiang; Cao, Zhipeng; Grissom, William A

    2016-06-01

    To implement and validate a hardware-based array-compressed parallel transmission (acpTx) system. In array-compressed parallel transmission, a small number of transmit channels drive a larger number of transmit coils, which are connected via an array compression network that implements optimized coil-to-channel combinations. A two channel-to-eight coil array compression network was developed using power splitters, attenuators and phase shifters, and a simulation was performed to investigate the effects of coil coupling on power dissipation in a simplified network. An eight coil transmit array was constructed using induced current elimination decoupling, and the coil and network were validated in benchtop measurements, B1+ mapping scans, and an accelerated spiral excitation experiment. The developed attenuators came within 0.08 dB of the desired attenuations, and reflection coefficients were -22 dB or better. The simulation demonstrated that up to 3× more power was dissipated in the network when coils were poorly isolated (-9.6 dB), versus well-isolated (-31 dB). Compared to split circularly-polarized coil combinations, the additional degrees of freedom provided by the array compression network led to 54% lower squared excitation error in the spiral experiment. Array-compressed parallel transmission was successfully implemented in a hardware system. Further work is needed to develop remote network tuning and to minimize network power dissipation. Magn Reson Med 75:2545-2552, 2016. © 2016 Wiley Periodicals, Inc. © 2016 Wiley Periodicals, Inc.

  5. Distributing coil elements in three dimensions enhances parallel transmission multiband RF performance: A simulation study in the human brain at 7 Tesla.

    PubMed

    Wu, Xiaoping; Tian, Jinfeng; Schmitter, Sebastian; Vaughan, J Tommy; Uğurbil, Kâmil; Van de Moortele, Pierre-François

    2016-06-01

    We explore the advantages of using a double-ring radiofrequency (RF) array and slice orientation to design parallel transmission (pTx) multiband (MB) pulses for simultaneous multislice (SMS) imaging with whole-brain coverage at 7 Tesla (T). A double-ring head array with 16 elements split evenly in two rings stacked in the z-direction was modeled and compared with two single-ring arrays consisting of 8 or 16 elements. The array performance was evaluated by designing band-specific pTx MB pulses with local specific absorption rate (SAR) control. The impact of slice orientations was also investigated. The double-ring array consistently and significantly outperformed the other two single-ring arrays, with peak local SAR reduced by up to 40% at a fixed excitation error of 0.024. For all three arrays, exciting sagittal or coronal slices yielded better RF performance than exciting axial or oblique slices. A double-ring RF array can be used to drastically improve SAR versus excitation fidelity tradeoff for pTx MB pulse design for brain imaging at 7 T; therefore, it is preferable against single-ring RF array designs when pursuing various biomedical applications of pTx SMS imaging. In comparing the stripline arrays, coronal and sagittal slices are more advantageous than axial and oblique slices for pTx MB pulses. Magn Reson Med 75:2464-2472, 2016. © 2016 Wiley Periodicals, Inc. © 2016 Wiley Periodicals, Inc.

  6. A novel coil array for combined TMS/fMRI experiments at 3 T

    PubMed Central

    Navarro de Lara, Lucia I.; Windischberger, Christian; Kuehne, Andre; Woletz, Michael; Sieg, Jürgen; Bestmann, Sven; Weiskopf, Nikolaus; Strasser, Bernhard; Moser, Ewald

    2014-01-01

    Purpose To overcome current limitations in combined transcranial magnetic stimulation (TMS) and functional magnetic resonance imaging (fMRI) studies by employing a dedicated coil array design for 3 Tesla. Methods The state‐of‐the‐art setup for concurrent TMS/fMRI is to use a large birdcage head coil, with the TMS between the subject's head and the MR coil. This setup has drawbacks in sensitivity, positioning, and available imaging techniques. In this study, an ultraslim 7‐channel receive‐only coil array for 3 T, which can be placed between the subject's head and the TMS, is presented. Interactions between the devices are investigated and the performance of the new setup is evaluated in comparison to the state‐of‐the‐art setup. Results MR sensitivity obtained at the depth of the TMS stimulation is increased by a factor of five. Parallel imaging with an acceleration factor of two is feasible with low g‐factors. Possible interactions between TMS and the novel hardware were investigated and were found negligible. Conclusion The novel coil array is safe, strongly improves signal‐to‐noise ratio in concurrent TMS/fMRI experiments, enables parallel imaging, and allows for flexible positioning of the TMS on the head while ensuring efficient TMS stimulation due to its ultraslim design. Magn Reson Med 74:1492–1501, 2015. © 2014 The Authors. Magnetic Resonance in Medicine published by Wiley Periodicals, Inc. on behalf of International Society for Magnetic Resonance in Medicine. PMID:25421603

  7. Dynamic multi-coil tailored excitation for transmit B1 correction at 7 Tesla.

    PubMed

    Umesh Rudrapatna, S; Juchem, Christoph; Nixon, Terence W; de Graaf, Robin A

    2016-07-01

    Tailored excitation (TEx) based on interspersing multiple radio frequency pulses with linear gradient and higher-order shim pulses can be used to obtain uniform flip angle in the presence of large radio frequency transmission (B 1+) inhomogeneity. Here, an implementation of dynamic, multislice tailored excitation using the recently developed multi-coil nonlinear shim hardware (MC-DTEx) is reported. MC-DTEx was developed and tested both in a phantom and in vivo at 7 T, and its efficacy was quantitatively assessed. Predicted outcomes of MC-DTEx and DTEx based on spherical harmonic shims (SH-DTEx) were also compared. For a planned 30 ° flip angle, in a phantom, the standard deviation in excitation improved from 28% (regular excitation) to 12% with MC-DTEx. The SD in in vivo excitation improved from 22 to 12%. The improvements achieved with experimental MC-DTEx closely matched the theoretical predictions. Simulations further showed that MC-DTEx outperforms SH-DTEx for both scenarios. Successful implementation of multislice MC-DTEx is presented and is shown to be capable of homogenizing excitation over more than twofold B 1+ variations. Its benefits over SH-DTEx are also demonstrated. A distinct advantage of MC hardware over SH shim hardware is the absence of significant eddy current effects, which allows for a straightforward, multislice implementation of MC-DTEx. Magn Reson Med 76:83-93, 2016. © 2015 Wiley Periodicals, Inc. © 2015 Wiley Periodicals, Inc.

  8. High-frame-rate full-vocal-tract 3D dynamic speech imaging.

    PubMed

    Fu, Maojing; Barlaz, Marissa S; Holtrop, Joseph L; Perry, Jamie L; Kuehn, David P; Shosted, Ryan K; Liang, Zhi-Pei; Sutton, Bradley P

    2017-04-01

    To achieve high temporal frame rate, high spatial resolution and full-vocal-tract coverage for three-dimensional dynamic speech MRI by using low-rank modeling and sparse sampling. Three-dimensional dynamic speech MRI is enabled by integrating a novel data acquisition strategy and an image reconstruction method with the partial separability model: (a) a self-navigated sparse sampling strategy that accelerates data acquisition by collecting high-nominal-frame-rate cone navigator sand imaging data within a single repetition time, and (b) are construction method that recovers high-quality speech dynamics from sparse (k,t)-space data by enforcing joint low-rank and spatiotemporal total variation constraints. The proposed method has been evaluated through in vivo experiments. A nominal temporal frame rate of 166 frames per second (defined based on a repetition time of 5.99 ms) was achieved for an imaging volume covering the entire vocal tract with a spatial resolution of 2.2 × 2.2 × 5.0 mm 3 . Practical utility of the proposed method was demonstrated via both validation experiments and a phonetics investigation. Three-dimensional dynamic speech imaging is possible with full-vocal-tract coverage, high spatial resolution and high nominal frame rate to provide dynamic speech data useful for phonetic studies. Magn Reson Med 77:1619-1629, 2017. © 2016 International Society for Magnetic Resonance in Medicine. © 2016 International Society for Magnetic Resonance in Medicine.

  9. Single-shot spiral imaging enabled by an expanded encoding model: Demonstration in diffusion MRI.

    PubMed

    Wilm, Bertram J; Barmet, Christoph; Gross, Simon; Kasper, Lars; Vannesjo, S Johanna; Haeberlin, Max; Dietrich, Benjamin E; Brunner, David O; Schmid, Thomas; Pruessmann, Klaas P

    2017-01-01

    The purpose of this work was to improve the quality of single-shot spiral MRI and demonstrate its application for diffusion-weighted imaging. Image formation is based on an expanded encoding model that accounts for dynamic magnetic fields up to third order in space, nonuniform static B 0 , and coil sensitivity encoding. The encoding model is determined by B 0 mapping, sensitivity mapping, and concurrent field monitoring. Reconstruction is performed by iterative inversion of the expanded signal equations. Diffusion-tensor imaging with single-shot spiral readouts is performed in a phantom and in vivo, using a clinical 3T instrument. Image quality is assessed in terms of artefact levels, image congruence, and the influence of the different encoding factors. Using the full encoding model, diffusion-weighted single-shot spiral imaging of high quality is accomplished both in vitro and in vivo. Accounting for actual field dynamics, including higher orders, is found to be critical to suppress blurring, aliasing, and distortion. Enhanced image congruence permitted data fusion and diffusion tensor analysis without coregistration. Use of an expanded signal model largely overcomes the traditional vulnerability of spiral imaging with long readouts. It renders single-shot spirals competitive with echo-planar readouts and thus deploys shorter echo times and superior readout efficiency for diffusion imaging and further prospective applications. Magn Reson Med 77:83-91, 2017. © 2016 International Society for Magnetic Resonance in Medicine. © 2016 International Society for Magnetic Resonance in Medicine.

  10. Inflow-vascular space occupancy (iVASO) reproducibility in the hippocampus and cortex at different blood water nulling times.

    PubMed

    Rane, Swati; Talati, Pratik; Donahue, Manus J; Heckers, Stephan

    2016-06-01

    Inflow-vascular space occupancy (iVASO) measures arterial cerebral blood volume (aCBV) using accurate blood water nulling (inversion time [TI]) when arterial blood reaches the capillary, i.e., at the arterial arrival time. This work assessed the reproducibility of iVASO measurements in the hippocampus and cortex at multiple TIs. The iVASO approach was implemented at multiple TIs in 10 healthy volunteers at 3 Tesla. aCBV values were measured at each TI in the left and right hippocampus, and the cortex. Reproducibility of aCBV measurements within scans (same day) and across sessions (different days) was assessed using the intraclass correlation coefficient (ICC). Overall hippocampal aCBV was significantly higher than cortical aCBV, likely due to higher gray matter volume. Hippocampal ICC values were high at short TIs (≤914 ms; intrascan values = 0.80-0.96, interscan values = 0.61-0.91). Cortically, high ICC values were observed at intermediate TIs of 914 (intra: 0.93, inter: 0.87) and 1034 ms (intra: 0.96, inter: 0.86). The ICC values were comparable to established contrast-based CBV measures. iVASO measurements are reproducible within and across sessions. TIs for iVASO measurements should be chosen carefully, taking into account heterogeneous arterial arrival times in different brain regions. Magn Reson Med 75:2379-2387, 2016. © 2015 Wiley Periodicals, Inc. © 2015 Wiley Periodicals, Inc.

  11. T2 shuffling: Sharp, multicontrast, volumetric fast spin-echo imaging.

    PubMed

    Tamir, Jonathan I; Uecker, Martin; Chen, Weitian; Lai, Peng; Alley, Marcus T; Vasanawala, Shreyas S; Lustig, Michael

    2017-01-01

    A new acquisition and reconstruction method called T 2 Shuffling is presented for volumetric fast spin-echo (three-dimensional [3D] FSE) imaging. T 2 Shuffling reduces blurring and recovers many images at multiple T 2 contrasts from a single acquisition at clinically feasible scan times (6-7 min). The parallel imaging forward model is modified to account for temporal signal relaxation during the echo train. Scan efficiency is improved by acquiring data during the transient signal decay and by increasing echo train lengths without loss in signal-to-noise ratio (SNR). By (1) randomly shuffling the phase encode view ordering, (2) constraining the temporal signal evolution to a low-dimensional subspace, and (3) promoting spatio-temporal correlations through locally low rank regularization, a time series of virtual echo time images is recovered from a single scan. A convex formulation is presented that is robust to partial voluming and radiofrequency field inhomogeneity. Retrospective undersampling and in vivo scans confirm the increase in sharpness afforded by T 2 Shuffling. Multiple image contrasts are recovered and used to highlight pathology in pediatric patients. A proof-of-principle method is integrated into a clinical musculoskeletal imaging workflow. The proposed T 2 Shuffling method improves the diagnostic utility of 3D FSE by reducing blurring and producing multiple image contrasts from a single scan. Magn Reson Med 77:180-195, 2017. © 2016 Wiley Periodicals, Inc. © 2016 Wiley Periodicals, Inc.

  12. Motion robust high resolution 3D free-breathing pulmonary MRI using dynamic 3D image self-navigator.

    PubMed

    Jiang, Wenwen; Ong, Frank; Johnson, Kevin M; Nagle, Scott K; Hope, Thomas A; Lustig, Michael; Larson, Peder E Z

    2018-06-01

    To achieve motion robust high resolution 3D free-breathing pulmonary MRI utilizing a novel dynamic 3D image navigator derived directly from imaging data. Five-minute free-breathing scans were acquired with a 3D ultrashort echo time (UTE) sequence with 1.25 mm isotropic resolution. From this data, dynamic 3D self-navigating images were reconstructed under locally low rank (LLR) constraints and used for motion compensation with one of two methods: a soft-gating technique to penalize the respiratory motion induced data inconsistency, and a respiratory motion-resolved technique to provide images of all respiratory motion states. Respiratory motion estimation derived from the proposed dynamic 3D self-navigator of 7.5 mm isotropic reconstruction resolution and a temporal resolution of 300 ms was successful for estimating complex respiratory motion patterns. This estimation improved image quality compared to respiratory belt and DC-based navigators. Respiratory motion compensation with soft-gating and respiratory motion-resolved techniques provided good image quality from highly undersampled data in volunteers and clinical patients. An optimized 3D UTE sequence combined with the proposed reconstruction methods can provide high-resolution motion robust pulmonary MRI. Feasibility was shown in patients who had irregular breathing patterns in which our approach could depict clinically relevant pulmonary pathologies. Magn Reson Med 79:2954-2967, 2018. © 2017 International Society for Magnetic Resonance in Medicine. © 2017 International Society for Magnetic Resonance in Medicine.

  13. Improved accuracy and precision of tracer kinetic parameters by joint fitting to variable flip angle and dynamic contrast enhanced MRI data.

    PubMed

    Dickie, Ben R; Banerji, Anita; Kershaw, Lucy E; McPartlin, Andrew; Choudhury, Ananya; West, Catharine M; Rose, Chris J

    2016-10-01

    To improve the accuracy and precision of tracer kinetic model parameter estimates for use in dynamic contrast enhanced (DCE) MRI studies of solid tumors. Quantitative DCE-MRI requires an estimate of precontrast T1 , which is obtained prior to fitting a tracer kinetic model. As T1 mapping and tracer kinetic signal models are both a function of precontrast T1 it was hypothesized that its joint estimation would improve the accuracy and precision of both precontrast T1 and tracer kinetic model parameters. Accuracy and/or precision of two-compartment exchange model (2CXM) parameters were evaluated for standard and joint fitting methods in well-controlled synthetic data and for 36 bladder cancer patients. Methods were compared under a number of experimental conditions. In synthetic data, joint estimation led to statistically significant improvements in the accuracy of estimated parameters in 30 of 42 conditions (improvements between 1.8% and 49%). Reduced accuracy was observed in 7 of the remaining 12 conditions. Significant improvements in precision were observed in 35 of 42 conditions (between 4.7% and 50%). In clinical data, significant improvements in precision were observed in 18 of 21 conditions (between 4.6% and 38%). Accuracy and precision of DCE-MRI parameter estimates are improved when signal models are fit jointly rather than sequentially. Magn Reson Med 76:1270-1281, 2016. © 2015 Wiley Periodicals, Inc. © 2015 Wiley Periodicals, Inc.

  14. Rigid-body motion correction of the liver in image reconstruction for golden-angle stack-of-stars DCE MRI.

    PubMed

    Johansson, Adam; Balter, James; Cao, Yue

    2018-03-01

    Respiratory motion can affect pharmacokinetic perfusion parameters quantified from liver dynamic contrast-enhanced MRI. Image registration can be used to align dynamic images after reconstruction. However, intra-image motion blur remains after alignment and can alter the shape of contrast-agent uptake curves. We introduce a method to correct for inter- and intra-image motion during image reconstruction. Sixteen liver dynamic contrast-enhanced MRI examinations of nine subjects were performed using a golden-angle stack-of-stars sequence. For each examination, an image time series with high temporal resolution but severe streak artifacts was reconstructed. Images were aligned using region-limited rigid image registration within a region of interest covering the liver. The transformations resulting from alignment were used to correct raw data for motion by modulating and rotating acquired lines in k-space. The corrected data were then reconstructed using view sharing. Portal-venous input functions extracted from motion-corrected images had significantly greater peak signal enhancements (mean increase: 16%, t-test, P <  0.001) than those from images aligned using image registration after reconstruction. In addition, portal-venous perfusion maps estimated from motion-corrected images showed fewer artifacts close to the edge of the liver. Motion-corrected image reconstruction restores uptake curves distorted by motion. Motion correction also reduces motion artifacts in estimated perfusion parameter maps. Magn Reson Med 79:1345-1353, 2018. © 2017 International Society for Magnetic Resonance in Medicine. © 2017 International Society for Magnetic Resonance in Medicine.

  15. Bone quantitative susceptibility mapping using a chemical species-specific R2* signal model with ultrashort and conventional echo data.

    PubMed

    Dimov, Alexey V; Liu, Zhe; Spincemaille, Pascal; Prince, Martin R; Du, Jiang; Wang, Yi

    2018-01-01

    To develop quantitative susceptibility mapping (QSM) of bone using an ultrashort echo time (UTE) gradient echo (GRE) sequence for signal acquisition and a bone-specific effective transverse relaxation rate ( R2*) to model water-fat MR signals for field mapping. Three-dimensional radial UTE data (echo times ≥ 40 μs) was acquired on a 3 Tesla scanner and fitted with a bone-specific signal model to map the chemical species and susceptibility field. Experiments were performed ex vivo on a porcine hoof and in vivo on healthy human subjects (n = 7). For water-fat separation, a bone-specific model assigning R2* decay mostly to water was compared with the standard models that assigned the same decay for both fat and water. In the ex vivo experiment, bone QSM was correlated with CT. Compared with standard models, the bone-specific R2* method significantly reduced errors in the fat fraction within the cortical bone in all tested data sets, leading to reduced artifacts in QSM. Good correlation was found between bone CT and QSM values in the porcine hoof (R 2  = 0.77). Bone QSM was successfully generated in all subjects. The QSM of bone is feasible using UTE with a conventional echo time GRE acquisition and a bone-specific R2* signal model. Magn Reson Med 79:121-128, 2018. © 2017 International Society for Magnetic Resonance in Medicine. © 2017 International Society for Magnetic Resonance in Medicine.

  16. Improving left ventricular segmentation in four-dimensional flow MRI using intramodality image registration for cardiac blood flow analysis.

    PubMed

    Gupta, Vikas; Bustamante, Mariana; Fredriksson, Alexandru; Carlhäll, Carl-Johan; Ebbers, Tino

    2018-01-01

    Assessment of blood flow in the left ventricle using four-dimensional flow MRI requires accurate left ventricle segmentation that is often hampered by the low contrast between blood and the myocardium. The purpose of this work is to improve left-ventricular segmentation in four-dimensional flow MRI for reliable blood flow analysis. The left ventricle segmentations are first obtained using morphological cine-MRI with better in-plane resolution and contrast, and then aligned to four-dimensional flow MRI data. This alignment is, however, not trivial due to inter-slice misalignment errors caused by patient motion and respiratory drift during breath-hold based cine-MRI acquisition. A robust image registration based framework is proposed to mitigate such errors automatically. Data from 20 subjects, including healthy volunteers and patients, was used to evaluate its geometric accuracy and impact on blood flow analysis. High spatial correspondence was observed between manually and automatically aligned segmentations, and the improvements in alignment compared to uncorrected segmentations were significant (P < 0.01). Blood flow analysis from manual and automatically corrected segmentations did not differ significantly (P > 0.05). Our results demonstrate the efficacy of the proposed approach in improving left-ventricular segmentation in four-dimensional flow MRI, and its potential for reliable blood flow analysis. Magn Reson Med 79:554-560, 2018. © 2017 International Society for Magnetic Resonance in Medicine. © 2017 International Society for Magnetic Resonance in Medicine.

  17. Alterations of neocortico-limbic association fibers and correlation with diet in prediabetes diagnosed by impaired fasting glucose.

    PubMed

    Hou, Yi-Cheng; Yang, Shwu-Huey; Wu, Yu-Te; Lai, Chien-Han

    2016-06-01

    To assess the existence of alterations in the micro-integrity of the fasciculus in prediabetic subjects. The issue of micro-integrity in white matter tracts has not been adequately addressed in prediabetes. Sixty-four prediabetic subjects and 54 controls were enrolled. All participants completed 24-hour diet records and 3-day diet records and received diffusion tensor imaging at 3T. The data for white matter micro-integrity were analyzed and compared between prediabetic subjects and controls with age and gender as covariates. In addition, voxel-wise regression between white matter micro-integrity, diet, and preprandial glucose levels were used to explore the relationship between white matter micro-integrity and diet or serum glucose levels. We found that prediabetic subjects had significant reductions in the micro-integrity of bilateral anterior thalamic radiation, left inferior longitudinal fasciculus, and left superior longitudinal fasciculus (corrected P < 0.05). In addition, total carbohydrate intake amount and preprandial serum glucose levels were negatively correlated with the micro-integrity in the left inferior longitudinal fasciculus and left anterior thalamic radiation (r: -0.47, corrected P < 0.05). Restrictive alterations in the white matter micro-integrity of the anterior thalamic radiation and inferior and superior longitudinal fasciculi might represent the initial "hot spots" for white matter tract alterations, which might play a role in the development of prediabetes. J. Magn. Reson. Imaging 2016;43:1500-1506. © 2016 Wiley Periodicals, Inc.

  18. Los cambios en la velocidad de rotación terrestre y los fenómenos geomagnéticos

    NASA Astrophysics Data System (ADS)

    Gianibelli, J. C.

    Uno de los aspectos importantes relativos a la geodinámica del interior terrestre es la correlación entre los eventos de cambio en la velocidad de rotación terrestre y los determinados en los elementos del campo geomagnético por ejemplo, la Declinación Magnética, o los coeficientes de los modelos matemáticos de representación global de dicho campo. En este trabajo se presentan los resultados de las características espectrales de los cambios observados en la longitud del día (ldd), y su relación con la estructura espectral de las coeficientes de los modelos matemáticos de campo denominados Campo Internacional Geomagnético de Referencia (CIGR). El intervalo estudiado comprende los últimos 100 años. Los resultados muestran una correlación en las bandas de 60 y 30 años, con posibles períodos mucho mayores que no son posibles determinar a partir de los modelos de CIRG. Se efectúa una simulación a partir de los resultados obtenidos por la aplicación del método de máxima entropía con longitudes del filtro predictor de error comprendida entre el 10% y el 95% de la longitud de la serie analizada. Se observan procesos sicrónicos y asincrónicos que, en muy largos intervalos de tiempos, podrían suponerse como caóticos.

  19. A numerical investigation on the effect of RF coil feed variability on global and local electromagnetic field exposure in human body models at 64 MHz.

    PubMed

    Lucano, Elena; Liberti, Micaela; Lloyd, Tom; Apollonio, Francesca; Wedan, Steve; Kainz, Wolfgang; Angelone, Leonardo M

    2018-02-01

    This study aims to investigate how the positions of the feeding sources of the transmit radiofrequency (RF) coil, field orientation direction with respect to the patient, and patient dimensions affect the global and local electromagnetic exposure in human body models. Three RF coil models were implemented, namely a specific two-source (S2) feed and two multisource feed configurations: generic 32-source (G32) and hybrid 16-source (H16). Thirty-two feeding conditions were studied for the S2, whereas two were studied for the G32 and H16. The study was performed using five human body models. Additionally, for two of the body models, the case of a partially implanted lead was evaluated. The results showed an overall variation due to coil feeding conditions of the whole-body specific absorption rate (SAR) of less than 20%, but deviations up to 98% of the magnitude of the electric field tangential to a possible lead path. For the analysis with the partially implanted lead, a variation of local SAR at the tip of the lead of up to 60% was observed with respect to feed position and field orientation direction. The results of this study suggest that specific information about feed position and field orientation direction must be considered for an accurate evaluation of patient exposure. Magn Reson Med 79:1135-1144, 2018. © 2017 International Society for Magnetic Resonance in Medicine. © 2017 International Society for Magnetic Resonance in Medicine.

  20. Fully automated atlas-based method for prescribing 3D PRESS MR spectroscopic imaging: Toward robust and reproducible metabolite measurements in human brain.

    PubMed

    Bian, Wei; Li, Yan; Crane, Jason C; Nelson, Sarah J

    2018-02-01

    To implement a fully automated atlas-based method for prescribing 3D PRESS MR spectroscopic imaging (MRSI). The PRESS selected volume and outer-volume suppression bands were predefined on the MNI152 standard template image. The template image was aligned to the subject T 1 -weighted image during a scan, and the resulting transformation was then applied to the predefined prescription. To evaluate the method, H-1 MRSI data were obtained in repeat scan sessions from 20 healthy volunteers. In each session, datasets were acquired twice without repositioning. The overlap ratio of the prescribed volume in the two sessions was calculated and the reproducibility of inter- and intrasession metabolite peak height and area ratios was measured by the coefficient of variation (CoV). The CoVs from intra- and intersession were compared by a paired t-test. The average overlap ratio of the automatically prescribed selection volumes between two sessions was 97.8%. The average voxel-based intersession CoVs were less than 0.124 and 0.163 for peak height and area ratios, respectively. Paired t-test showed no significant difference between the intra- and intersession CoVs. The proposed method provides a time efficient method to prescribe 3D PRESS MRSI with reproducible imaging positioning and metabolite measurements. Magn Reson Med 79:636-642, 2018. © 2017 International Society for Magnetic Resonance in Medicine. © 2017 International Society for Magnetic Resonance in Medicine.

  1. Polarized Linear Motor Combined With Levitation Actuators Working in a Partial Vacuum Environment—Application to Swissmetro

    NASA Astrophysics Data System (ADS)

    Cassat, Alain; Espanet, Christophe; Bourquin, Vincent; Hagmann, Pascal; Jufer, Marcel

    Worldwide high speed Maglev (> 400km/h) developments refer to Maglev such as the Japanese JR-Maglev MLX, the German Transrapid and the USA Inductrack Maglev. Other world projects exist such as the Japan HSST (< 300km/h) and the China HTC. The JR-Maglev, the Transrapid and the HSST have reached industrial levels. The Swissmetro Project presents a unique aspect of Maglev: it is designed to work under partial vacuum (< 10kPa) in two tunnels and for high speeds (>400km/h). The authors investigate new possibilities to combine both the propulsion and the levitation. In order to minimize the heat due to the motor levitation and guidance losses, a polarized excitation is proposed. The use of permanent magnet NdFeB for the excitation is still not applied for high speed Maglev, requiring mechanical power greater than 6MW. Such a solution only appears in Urban Rapid Transit Maglev (<160km/h), such as the USA MagneMotion M3 and the General Atomic Urban Maglev. For Swissmetro, the authors study the polarized inductors for the levitation, implying a polarized synchronous linear motor. The polarization is obtained with permanent magnets NdFeB. This paper presents some key issues related to such technical choices. The motor design is described and the power balance is presented. The thermal behavior is analyzed using a numerical platform of the complete vehicle-tunnel system, based on computation of the air flow dynamic.

  2. Robust water fat separated dual-echo MRI by phase-sensitive reconstruction.

    PubMed

    Romu, Thobias; Dahlström, Nils; Leinhard, Olof Dahlqvist; Borga, Magnus

    2017-09-01

    The purpose of this work was to develop and evaluate a robust water-fat separation method for T1-weighted symmetric two-point Dixon data. A method for water-fat separation by phase unwrapping of the opposite-phase images by phase-sensitive reconstruction (PSR) is introduced. PSR consists of three steps; (1), identification of clusters of tissue voxels; (2), unwrapping of the phase in each cluster by solving Poisson's equation; and (3), finding the correct sign of each unwrapped opposite-phase cluster, so that the water-fat images are assigned the correct identities. Robustness was evaluated by counting the number of water-fat swap artifacts in a total of 733 image volumes. The method was also compared to commercial software. In the water-fat separated image volumes, the PSR method failed to unwrap the phase of one cluster and misclassified 10. One swap was observed in areas affected by motion and was constricted to the affected area. Twenty swaps were observed surrounding susceptibility artifacts, none of which spread outside the artifact affected regions. The PSR method had fewer swaps when compared to commercial software. The PSR method can robustly produce water-fat separated whole-body images based on symmetric two-echo spoiled gradient echo images, under both ideal conditions and in the presence of common artifacts. Magn Reson Med 78:1208-1216, 2017. © 2016 International Society for Magnetic Resonance in Medicine. © 2016 International Society for Magnetic Resonance in Medicine.

  3. In Vivo Monitoring of pH, Redox Status, and Glutathione Using L-Band EPR for Assessment of Therapeutic Effectiveness in Solid Tumors

    PubMed Central

    Bobko, Andrey A.; Eubank, Timothy D.; Voorhees, Jeffrey L.; Efimova, Olga V.; Kirilyuk, Igor A.; Petryakov, Sergey; Trofimiov, Dmitrii G.; Marsh, Clay B.; Zweier, Jay L.; Grigor’ev, Igor A.; Samouilov, Alexandre; Khramtsov, Valery V.

    2011-01-01

    Approach for in vivo real-time assessment of tumor tissue extracellular pH (pHe), redox, and intracellular glutathione based on L-band EPR spectroscopy using dual function pH and redox nitroxide probe and disulfide nitroxide biradical, is described. These parameters were monitored in PyMT mice bearing breast cancer tumors during treatment with granulocyte macrophage colony-stimulating factor. It was observed that tumor pHe is about 0.4 pH units lower than that in normal mammary gland tissue. Treatment with granulocyte macrophage colony-stimulating factor decreased the value of pHe by 0.3 units compared with PBS control treatment. Tumor tissue reducing capacity and intracellular glutathione were elevated compared with normal mammary gland tissue. Granulocyte macrophage colony-stimulating factor treatment resulted in a decrease of the tumor tissue reducing capacity and intracellular glutathione content. In addition to spectroscopic studies, pHe mapping was performed using recently proposed variable frequency proton–electron double-resonance imaging. The pH mapping superimposed with MRI image supports probe localization in mammary gland/tumor tissue, shows high heterogeneity of tumor tissue pHe and a difference of about 0.4 pH units between average pHe values in tumor and normal mammary gland. In summary, the developed multifunctional approach allows for in vivo, noninvasive pHe, extracellular redox, and intracellular glutathione content monitoring during investigation of various therapeutic strategies for solid tumors. Magn Reson Med 000:000–000, 2011. PMID:22113626

  4. Méthode de prédétermination des caractéristiques électromagnétiques de machines á bobinage global à commutation de flux. Application à un actionneur linéaire

    NASA Astrophysics Data System (ADS)

    Prevond, L.; Ben Ahmed, A.; Multon, B.; Lucidarme, J.

    1997-06-01

    This paper presents a predetermination method of Permanent Magnet (P.M.) multicellular flux switching machines. The non-linear characteristic of the ferromagnetic material is integrated in this method which combines analytical and numerical calculus. This study permits to make a fast parametrical analysis to define optimal parameters of a flux switching cell such as magnetic shear stress and flux concentration factor as function of magnetomotive force. The demagnetisation limit is introduced by a finite element calculus applied. The comparison of the theoritical results and experimental one gives a good correlation. Cet article présente une méthode de prédétermination des caractéristiques de machines multicellulaires (bobinage global) à commutation de flux (aimants permanents) en tenant compte de la non linéarité des matériaux ferromagnétiques. Cette méthode allie le calcul numérique par éléments finis et le calcul analytique. Cette étude nous a permis, d'une part, d'effectuer une analyse paramétrique intrinsèque et, d'autre part, de définir les paramètres optimaux de la cellule à commutation de flux. La notion de désaimantation est introduite en calculant le champ démagnétisant dans l'aimant. Les calculs effectués, dans le cas d'un actionneur linéaire à cômmutation de flux, montrent une bonne corrélation avec les essais directs.

  5. B0 concomitant field compensation for MRI systems employing asymmetric transverse gradient coils.

    PubMed

    Weavers, Paul T; Tao, Shengzhen; Trzasko, Joshua D; Frigo, Louis M; Shu, Yunhong; Frick, Matthew A; Lee, Seung-Kyun; Foo, Thomas K-F; Bernstein, Matt A

    2018-03-01

    Imaging gradients result in the generation of concomitant fields, or Maxwell fields, which are of increasing importance at higher gradient amplitudes. These time-varying fields cause additional phase accumulation, which must be compensated for to avoid image artifacts. In the case of gradient systems employing symmetric design, the concomitant fields are well described with second-order spatial variation. Gradient systems employing asymmetric design additionally generate concomitant fields with global (zeroth-order or B 0 ) and linear (first-order) spatial dependence. This work demonstrates a general solution to eliminate the zeroth-order concomitant field by applying the correct B 0 frequency shift in real time to counteract the concomitant fields. Results are demonstrated for phase contrast, spiral, echo-planar imaging (EPI), and fast spin-echo imaging. A global phase offset is reduced in the phase-contrast exam, and blurring is virtually eliminated in spiral images. The bulk image shift in the phase-encode direction is compensated for in EPI, whereas signal loss, ghosting, and blurring are corrected in the fast-spin echo images. A user-transparent method to compensate the zeroth-order concomitant field term by center frequency shifting is proposed and implemented. This solution allows all the existing pulse sequences-both product and research-to be retained without any modifications. Magn Reson Med 79:1538-1544, 2018. © 2017 International Society for Magnetic Resonance in Medicine. © 2017 International Society for Magnetic Resonance in Medicine.

  6. Utility of histogram analysis of apparent diffusion coefficient maps obtained using 3.0T MRI for distinguishing uterine carcinosarcoma from endometrial carcinoma.

    PubMed

    Takahashi, Masahiro; Kozawa, Eito; Tanisaka, Megumi; Hasegawa, Kousei; Yasuda, Masanori; Sakai, Fumikazu

    2016-06-01

    We explored the role of histogram analysis of apparent diffusion coefficient (ADC) maps for discriminating uterine carcinosarcoma and endometrial carcinoma. We retrospectively evaluated findings in 13 patients with uterine carcinosarcoma and 50 patients with endometrial carcinoma who underwent diffusion-weighted imaging (b = 0, 500, 1000 s/mm(2) ) at 3T with acquisition of corresponding ADC maps. We derived histogram data from regions of interest drawn on all slices of the ADC maps in which tumor was visualized, excluding areas of necrosis and hemorrhage in the tumor. We used the Mann-Whitney test to evaluate the capacity of histogram parameters (mean ADC value, 5th to 95th percentiles, skewness, kurtosis) to discriminate uterine carcinosarcoma and endometrial carcinoma and analyzed the receiver operating characteristic (ROC) curve to determine the optimum threshold value for each parameter and its corresponding sensitivity and specificity. Carcinosarcomas demonstrated significantly higher mean vales of ADC, 95th, 90th, 75th, 50th, 25th percentiles and kurtosis than endometrial carcinomas (P < 0.05). ROC curve analysis of the 75th percentile yielded the best area under the ROC curve (AUC; 0.904), sensitivity of 100%, and specificity of 78.0%, with a cutoff value of 1.034 × 10(-3) mm(2) /s. Histogram analysis of ADC maps might be helpful for discriminating uterine carcinosarcomas and endometrial carcinomas. J. Magn. Reson. Imaging 2016;43:1301-1307. © 2015 Wiley Periodicals, Inc.

  7. Four-dimensional respiratory motion-resolved whole heart coronary MR angiography.

    PubMed

    Piccini, Davide; Feng, Li; Bonanno, Gabriele; Coppo, Simone; Yerly, Jérôme; Lim, Ruth P; Schwitter, Juerg; Sodickson, Daniel K; Otazo, Ricardo; Stuber, Matthias

    2017-04-01

    Free-breathing whole-heart coronary MR angiography (MRA) commonly uses navigators to gate respiratory motion, resulting in lengthy and unpredictable acquisition times. Conversely, self-navigation has 100% scan efficiency, but requires motion correction over a broad range of respiratory displacements, which may introduce image artifacts. We propose replacing navigators and self-navigation with a respiratory motion-resolved reconstruction approach. Using a respiratory signal extracted directly from the imaging data, individual signal-readouts are binned according to their respiratory states. The resultant series of undersampled images are reconstructed using an extradimensional golden-angle radial sparse parallel imaging (XD-GRASP) algorithm, which exploits sparsity along the respiratory dimension. Whole-heart coronary MRA was performed in 11 volunteers and four patients with the proposed methodology. Image quality was compared with that obtained with one-dimensional respiratory self-navigation. Respiratory-resolved reconstruction effectively suppressed respiratory motion artifacts. The quality score for XD-GRASP reconstructions was greater than or equal to self-navigation in 80/88 coronary segments, reaching diagnostic quality in 61/88 segments versus 41/88. Coronary sharpness and length were always superior for the respiratory-resolved datasets, reaching statistical significance (P < 0.05) in most cases. XD-GRASP represents an attractive alternative for handling respiratory motion in free-breathing whole heart MRI and provides an effective alternative to self-navigation. Magn Reson Med 77:1473-1484, 2017. © 2016 International Society for Magnetic Resonance in Medicine. © 2016 International Society for Magnetic Resonance in Medicine.

  8. Localized, gradient-reversed ultrafast z-spectroscopy in vivo at 7T.

    PubMed

    Wilson, Neil E; D'Aquilla, Kevin; Debrosse, Catherine; Hariharan, Hari; Reddy, Ravinder

    2016-10-01

    To collect ultrafast z-spectra in vivo in situations where voxel homogeneity cannot be assured. Saturating in the presence of a gradient encodes the frequency offset spatially across a voxel. This encoding can be resolved by applying a similar gradient during readout. Acquiring additional scans with the gradient polarity reversed effectively mirrors the spatial locations of the frequency offsets so that the same physical location of a positive offset in the original scan will contribute a negative offset in the gradient-reversed scan. Gradient-reversed ultrafast z-spectroscopy (GRUFZS) was implemented and tested in a modified, localized PRESS sequence at 7T. Lysine phantoms were scanned at various concentrations and compared with coventionally-acquired z-spectra. Scans were acquired in vivo in human brain from homogeneous and inhomogeneous voxels with the ultrafast direction cycled between read, phase, and slice. Results were compared to those from a similar conventional z-spectroscopy PRESS-based sequence. Asymmetry spectra from GRUFZS are more consistent and reliable than those without gradient reversal and are comparable to those from conventional z-spectroscopy. GRUFZS offers significant acceleration in data acquisition compared to traditional chemical exchange saturation transfer methods with high spectral resolution and showed higher relative SNR effficiency. GRUFZS offers a method of collecting ultrafast z-spectra in voxels with the inhomogeneity often found in vivo. Magn Reson Med 76:1039-1046, 2016. © 2016 Wiley Periodicals, Inc. © 2016 Wiley Periodicals, Inc.

  9. Externally calibrated parallel imaging for 3D multispectral imaging near metallic implants using broadband ultrashort echo time imaging.

    PubMed

    Wiens, Curtis N; Artz, Nathan S; Jang, Hyungseok; McMillan, Alan B; Reeder, Scott B

    2017-06-01

    To develop an externally calibrated parallel imaging technique for three-dimensional multispectral imaging (3D-MSI) in the presence of metallic implants. A fast, ultrashort echo time (UTE) calibration acquisition is proposed to enable externally calibrated parallel imaging techniques near metallic implants. The proposed calibration acquisition uses a broadband radiofrequency (RF) pulse to excite the off-resonance induced by the metallic implant, fully phase-encoded imaging to prevent in-plane distortions, and UTE to capture rapidly decaying signal. The performance of the externally calibrated parallel imaging reconstructions was assessed using phantoms and in vivo examples. Phantom and in vivo comparisons to self-calibrated parallel imaging acquisitions show that significant reductions in acquisition times can be achieved using externally calibrated parallel imaging with comparable image quality. Acquisition time reductions are particularly large for fully phase-encoded methods such as spectrally resolved fully phase-encoded three-dimensional (3D) fast spin-echo (SR-FPE), in which scan time reductions of up to 8 min were obtained. A fully phase-encoded acquisition with broadband excitation and UTE enabled externally calibrated parallel imaging for 3D-MSI, eliminating the need for repeated calibration regions at each frequency offset. Significant reductions in acquisition time can be achieved, particularly for fully phase-encoded methods like SR-FPE. Magn Reson Med 77:2303-2309, 2017. © 2016 International Society for Magnetic Resonance in Medicine. © 2016 International Society for Magnetic Resonance in Medicine.

  10. MRI monitoring of focused ultrasound sonications near metallic hardware.

    PubMed

    Weber, Hans; Ghanouni, Pejman; Pascal-Tenorio, Aurea; Pauly, Kim Butts; Hargreaves, Brian A

    2018-07-01

    To explore the temperature-induced signal change in two-dimensional multi-spectral imaging (2DMSI) for fast thermometry near metallic hardware to enable MR-guided focused ultrasound surgery (MRgFUS) in patients with implanted metallic hardware. 2DMSI was optimized for temperature sensitivity and applied to monitor focus ultrasound surgery (FUS) sonications near metallic hardware in phantoms and ex vivo porcine muscle tissue. Further, we evaluated its temperature sensitivity for in vivo muscle in patients without metallic hardware. In addition, we performed a comparison of temperature sensitivity between 2DMSI and conventional proton-resonance-frequency-shift (PRFS) thermometry at different distances from metal devices and different signal-to-noise ratios (SNR). 2DMSI thermometry enabled visualization of short ultrasound sonications near metallic hardware. Calibration using in vivo muscle yielded a constant temperature sensitivity for temperatures below 43 °C. For an off-resonance coverage of ± 6 kHz, we achieved a temperature sensitivity of 1.45%/K, resulting in a minimum detectable temperature change of ∼2.5 K for an SNR of 100 with a temporal resolution of 6 s per frame. The proposed 2DMSI thermometry has the potential to allow MR-guided FUS treatments of patients with metallic hardware and therefore expand its reach to a larger patient population. Magn Reson Med 80:259-271, 2018. © 2017 International Society for Magnetic Resonance in Medicine. © 2017 International Society for Magnetic Resonance in Medicine.

  11. Initial investigation of a novel noninvasive weight loss therapy using MRI-Guided high intensity focused ultrasound (MR-HIFU) of visceral fat.

    PubMed

    Winter, Patrick M; Lanier, Matthew; Partanen, Ari; Dumoulin, Charles

    2016-07-01

    MRI-guided high intensity focused ultrasound (MR-HIFU) allows noninvasive heating of deep tissues. Specifically targeting visceral fat deposits with MR-HIFU could offer an effective therapy for reversing the development of obesity, diabetes, and metabolic syndrome. Overweight rats received either MR-HIFU of visceral fat, sham treatment, no treatment, or ex vivo temperature calibration. Conventional MR thermometry methods are not effective in fat tissue. Therefore, the T2 of fat was used to estimate heating in adipose tissue. HIFU treated rats lost 7.5% of their body weight 10 days after HIFU, compared with 1.9% weight loss in sham animals (P = 0.008) and 1.3% weight increase in untreated animals (P = 0.004). Additionally, the abdominal fat volume in treated animals decreased by 8.2 mL 7 days after treatment (P = 0.002). The T2 of fat at 1.5 Tesla increased by 3.3 ms per °C. The fat T2 was 103.3 ms before HIFU, but increased to 128.7 ms (P = 0.0005) after HIFU at 70 watts for 16 s and to 131.9 ms (P = 0.0005) after HIFU at 100 watts for 16 s. These experiments demonstrate that MR-HIFU of visceral fat could provide a safe, effective, and noninvasive weight loss therapy for combating obesity and the subsequent medical complications. Magn Reson Med 76:282-289, 2016. © 2015 Wiley Periodicals, Inc. © 2015 Wiley Periodicals, Inc.

  12. Golden-ratio rotated stack-of-stars acquisition for improved volumetric MRI.

    PubMed

    Zhou, Ziwu; Han, Fei; Yan, Lirong; Wang, Danny J J; Hu, Peng

    2017-12-01

    To develop and evaluate an improved stack-of-stars radial sampling strategy for reducing streaking artifacts. The conventional stack-of-stars sampling strategy collects the same radial angle for every partition (slice) encoding. In an undersampled acquisition, such an aligned acquisition generates coherent aliasing patterns and introduces strong streaking artifacts. We show that by rotating the radial spokes in a golden-angle manner along the partition-encoding direction, the aliasing pattern is modified, resulting in improved image quality for gridding and more advanced reconstruction methods. Computer simulations were performed and phantom as well as in vivo images for three different applications were acquired. Simulation, phantom, and in vivo experiments confirmed that the proposed method was able to generate images with less streaking artifact and sharper structures based on undersampled acquisitions in comparison with the conventional aligned approach at the same acceleration factors. By combining parallel imaging and compressed sensing in the reconstruction, streaking artifacts were mostly removed with improved delineation of fine structures using the proposed strategy. We present a simple method to reduce streaking artifacts and improve image quality in 3D stack-of-stars acquisitions by re-arranging the radial spoke angles in the 3D partition direction, which can be used for rapid volumetric imaging. Magn Reson Med 78:2290-2298, 2017. © 2017 International Society for Magnetic Resonance in Medicine. © 2017 International Society for Magnetic Resonance in Medicine.

  13. Z-spectrum appearance and interpretation in the presence of fat: Influence of acquisition parameters.

    PubMed

    Zhang, Shu; Keupp, Jochen; Wang, Xinzeng; Dimitrov, Ivan; Madhuranthakam, Ananth J; Lenkinski, Robert E; Vinogradov, Elena

    2018-05-01

    Chemical exchange saturation transfer (CEST) MRI is increasingly evolving from brain to body applications. One of the known problems in the body imaging is the presence of strong lipid signals. Although their influence on the CEST effect is acknowledged, there was no study that focuses on the interplay among echo time, fat fraction, and Z-spectrum. This study strives to address these points, with the emphasis on the application in the breast. Z-spectra were simulated in phase and out of phase of the main fat peak at -3.4 ppm, with the fat fraction varying from 0 to 100%. The magnetization transfer ratio asymmetry in two ranges, centering at the exchanging pool and at 3.5 ppm approximately opposite the nonexchanging fat pool, were calculated and were plotted against fat fraction. The results were verified in phantoms and in vivo. The results demonstrate the combined influence of fat fraction and echo time on the Z-spectrum for gradient echo based CEST acquisitions. The influence is straightforward in the in-phase images, but it is more complicated in the out-of-phase images, potentially leading to erroneous CEST contrast. This study provides a basis for understanding the origin and appearance of lipid artifacts in CEST imaging, and lays the foundation for their efficient removal. Magn Reson Med 79:2731-2737, 2018. © 2017 International Society for Magnetic Resonance in Medicine. © 2017 International Society for Magnetic Resonance in Medicine.

  14. Ependimoma myxopapilar sacro gigante con osteolisis

    PubMed Central

    Ajler, Pablo; Landriel, Federico; Goldschmidt, Ezequiel; Campero, Álvaro; Yampolsky, Claudio

    2014-01-01

    Objetivo: la presentación de un caso de una paciente con un ependimoma sacro con extensa infiltración y destrucción ósea local. Descripción del caso: una mujer de 53 años acudió a la consulta por dolor lumbosacro y alteraciones sensitivas perineales y esfinterianas. La imágenes por Resonancia Magnética (IRM) y la Tomografía Axial Computada (TAC) mostraron una lesión expansiva gigante a nivel S2-S4 con extensa osteólisis e invasión de tejidos adyacentes. Se realizó una exéresis tumoral completa con mejoría del estatus funcional. La anatomía patológica informó ependimoma mixopapilar. Discusión: la extensión de la resección quirúrgica es el mejor predictor de buen pronóstico. El tratamiento radiante se reserva como opción adyuvante para las resecciones incompletas y recidiva tumoral. La quimioterapia sólo debería utilizarse en casos en que la cirugía y la radioterapia estén contraindicadas. Conclusión: Los ependimomas mixopapilares sacros con destrucción ósea y presentación intra y extradural son muy infrecuentes y deben ser tenidos en cuenta entre los diagnósticos diferenciales preoperatorios. Su resección total, siempre que sea posible, es la mejor alternativa terapéutica. PMID:25165615

  15. Gradient pre-emphasis to counteract first-order concomitant fields on asymmetric MRI gradient systems.

    PubMed

    Tao, Shengzhen; Weavers, Paul T; Trzasko, Joshua D; Shu, Yunhong; Huston, John; Lee, Seung-Kyun; Frigo, Louis M; Bernstein, Matt A

    2017-06-01

    To develop a gradient pre-emphasis scheme that prospectively counteracts the effects of the first-order concomitant fields for any arbitrary gradient waveform played on asymmetric gradient systems, and to demonstrate the effectiveness of this approach using a real-time implementation on a compact gradient system. After reviewing the first-order concomitant fields that are present on asymmetric gradients, we developed a generalized gradient pre-emphasis model assuming arbitrary gradient waveforms to counteract their effects. A numerically straightforward, easily implemented approximate solution to this pre-emphasis problem was derived that was compatible with the current hardware infrastructure of conventional MRI scanners for eddy current compensation. The proposed method was implemented on the gradient driver subsystem, and its real-time use was tested using a series of phantom and in vivo data acquired from two-dimensional Cartesian phase-difference, echo-planar imaging, and spiral acquisitions. The phantom and in vivo results demonstrated that unless accounted for, first-order concomitant fields introduce considerable phase estimation error into the measured data and result in images with spatially dependent blurring/distortion. The resulting artifacts were effectively prevented using the proposed gradient pre-emphasis. We have developed an efficient and effective gradient pre-emphasis framework to counteract the effects of first-order concomitant fields of asymmetric gradient systems. Magn Reson Med 77:2250-2262, 2017. © 2016 International Society for Magnetic Resonance in Medicine. © 2016 International Society for Magnetic Resonance in Medicine.

  16. On the accurate analysis of vibroacoustics in head insert gradient coils.

    PubMed

    Winkler, Simone A; Alejski, Andrew; Wade, Trevor; McKenzie, Charles A; Rutt, Brian K

    2017-10-01

    To accurately analyze vibroacoustics in MR head gradient coils. A detailed theoretical model for gradient coil vibroacoustics, including the first description and modeling of Lorentz damping, is introduced and implemented in a multiphysics software package. Numerical finite-element method simulations were used to establish a highly accurate vibroacoustic model in head gradient coils in detail, including the newly introduced Lorentz damping effect. Vibroacoustic coupling was examined through an additional modal analysis. Thorough experimental studies were used to validate simulations. Average experimental sound pressure levels (SPLs) and accelerations over the 0-3000 Hz frequency range were 97.6 dB, 98.7 dB, and 95.4 dB, as well as 20.6 g, 8.7 g, and 15.6 g for the X-, Y-, and Z-gradients, respectively. A reasonable agreement between simulations and measurements was achieved. Vibroacoustic coupling showed a coupled resonance at 2300 Hz for the Z-gradient that is responsible for a sharp peak and the highest SPL value in the acoustic spectrum. We have developed and used more realistic multiphysics simulation methods to gain novel insights into the underlying concepts for vibroacoustics in head gradient coils, which will permit improved analyses of existing gradient coils and novel SPL reduction strategies for future gradient coil designs. Magn Reson Med 78:1635-1645, 2017. © 2016 International Society for Magnetic Resonance in Medicine. © 2016 International Society for Magnetic Resonance in Medicine.

  17. A rapid and robust gradient measurement technique using dynamic single-point imaging.

    PubMed

    Jang, Hyungseok; McMillan, Alan B

    2017-09-01

    We propose a new gradient measurement technique based on dynamic single-point imaging (SPI), which allows simple, rapid, and robust measurement of k-space trajectory. To enable gradient measurement, we utilize the variable field-of-view (FOV) property of dynamic SPI, which is dependent on gradient shape. First, one-dimensional (1D) dynamic SPI data are acquired from a targeted gradient axis, and then relative FOV scaling factors between 1D images or k-spaces at varying encoding times are found. These relative scaling factors are the relative k-space position that can be used for image reconstruction. The gradient measurement technique also can be used to estimate the gradient impulse response function for reproducible gradient estimation as a linear time invariant system. The proposed measurement technique was used to improve reconstructed image quality in 3D ultrashort echo, 2D spiral, and multi-echo bipolar gradient-echo imaging. In multi-echo bipolar gradient-echo imaging, measurement of the k-space trajectory allowed the use of a ramp-sampled trajectory for improved acquisition speed (approximately 30%) and more accurate quantitative fat and water separation in a phantom. The proposed dynamic SPI-based method allows fast k-space trajectory measurement with a simple implementation and no additional hardware for improved image quality. Magn Reson Med 78:950-962, 2017. © 2016 International Society for Magnetic Resonance in Medicine. © 2016 International Society for Magnetic Resonance in Medicine.

  18. Development and implementation of an 84-channel matrix gradient coil.

    PubMed

    Littin, Sebastian; Jia, Feng; Layton, Kelvin J; Kroboth, Stefan; Yu, Huijun; Hennig, Jürgen; Zaitsev, Maxim

    2018-02-01

    Design, implement, integrate, and characterize a customized coil system that allows for generating spatial encoding magnetic fields (SEMs) in a highly-flexible fashion. A gradient coil with a high number of individual elements was designed. Dimensions of the coil were chosen to mimic a whole-body gradient system, scaled down to a head insert. Mechanical shape and wire layout of each element were optimized to increase the local gradient strength while minimizing eddy current effects and simultaneously considering manufacturing constraints. Resulting wire layout and mechanical design is presented. A prototype matrix gradient coil with 12 × 7 = 84 elements consisting of two element types was realized and characterized. Measured eddy currents are <1% of the original field. The coil is shown to be capable of creating nonlinear, and linear SEMs. In a DSV of 0.22 m gradient strengths between 24 mT∕m and 78 mT∕m could be realized locally with maximum currents of 150 A. Initial proof-of-concept imaging experiments using linear and nonlinear encoding fields are demonstrated. A shielded matrix gradient coil setup capable of generating encoding fields in a highly-flexible manner was designed and implemented. The presented setup is expected to serve as a basis for validating novel imaging techniques that rely on nonlinear spatial encoding fields. Magn Reson Med 79:1181-1191, 2018. © 2017 International Society for Magnetic Resonance in Medicine. © 2017 International Society for Magnetic Resonance in Medicine.

  19. Highly efficient nonrigid motion‐corrected 3D whole‐heart coronary vessel wall imaging

    PubMed Central

    Atkinson, David; Henningsson, Markus; Botnar, Rene M.; Prieto, Claudia

    2016-01-01

    Purpose To develop a respiratory motion correction framework to accelerate free‐breathing three‐dimensional (3D) whole‐heart coronary lumen and coronary vessel wall MRI. Methods We developed a 3D flow‐independent approach for vessel wall imaging based on the subtraction of data with and without T2‐preparation prepulses acquired interleaved with image navigators. The proposed method corrects both datasets to the same respiratory position using beat‐to‐beat translation and bin‐to‐bin nonrigid corrections, producing coregistered, motion‐corrected coronary lumen and coronary vessel wall images. The proposed method was studied in 10 healthy subjects and was compared with beat‐to‐beat translational correction (TC) and no motion correction for the left and right coronary arteries. Additionally, the coronary lumen images were compared with a 6‐mm diaphragmatic navigator gated and tracked scan. Results No significant differences (P > 0.01) were found between the proposed method and the gated and tracked scan for coronary lumen, despite an average improvement in scan efficiency to 96% from 59%. Significant differences (P < 0.01) were found in right coronary artery vessel wall thickness, right coronary artery vessel wall sharpness, and vessel wall visual score between the proposed method and TC. Conclusion The feasibility of a highly efficient motion correction framework for simultaneous whole‐heart coronary lumen and vessel wall has been demonstrated. Magn Reson Med 77:1894–1908, 2017. © 2016 International Society for Magnetic Resonance in Medicine PMID:27221073

  20. In Vivo Proton–Electron Double-Resonance Imaging of Extracellular Tumor pH Using an Advanced Nitroxide Probe

    PubMed Central

    Samouilov, Alexandre; Efimova, Olga V.; Bobko, Andrey A.; Sun, Ziqi; Petryakov, Sergey; Eubank, Timothy D.; Trofimov, Dmitrii G.; Kirilyuk, Igor A.; Grigor’ev, Igor A.; Takahashi, Wataru; Zweier, Jay L.; Khramtsov, Valery V.

    2014-01-01

    A variable radio frequency proton–electron double-resonance imaging (VRF PEDRI) approach for pH mapping of aqueous samples has been recently developed (Efimova et al. J. Magn. Reson. 2011, 209, 227–232). A pH map is extracted from two PEDRI acquisitions performed at electron paramagnetic resonance (EPR) frequencies of protonated and unprotonated forms of a pH-sensitive probe. To translate VRF PEDRI to an in vivo setting, an advanced pH probe was synthesized. Probe deuteration resulted in a narrow spectral line of 1.2 G compared to a nondeuterated analogue line width of 2.1 G allowing for an increase of Overhauser enhancements and reduction in rf power deposition. Binding of the probe to the cell-impermeable tripeptide, glutathione (GSH), allows for targeting to extracellular tissue space for monitoring extracellular tumor acidosis, a prognostic factor in tumor pathophysiology. The probe demonstrated pH sensitivity in the 5.8–7.8 range, optimum for measurement of acidic extracellular tumor pH (pHe). In vivo VRF PEDRI was performed on Met-1 tumor-bearing mice. Compared to normal mammary glands with a neutral mean pHe (7.1 ± 0.1), we observed broader pH distribution with acidic mean pHe (6.8 ± 0.1) in tumor tissue. In summary, VRF PEDRI in combination with a newly developed pH probe provides an analytical approach for spatially resolved noninvasive pHe monitoring, in vivo. PMID:24372284

  1. Autocalibrating motion-corrected wave-encoding for highly accelerated free-breathing abdominal MRI.

    PubMed

    Chen, Feiyu; Zhang, Tao; Cheng, Joseph Y; Shi, Xinwei; Pauly, John M; Vasanawala, Shreyas S

    2017-11-01

    To develop a motion-robust wave-encoding technique for highly accelerated free-breathing abdominal MRI. A comprehensive 3D wave-encoding-based method was developed to enable fast free-breathing abdominal imaging: (a) auto-calibration for wave-encoding was designed to avoid extra scan for coil sensitivity measurement; (b) intrinsic butterfly navigators were used to track respiratory motion; (c) variable-density sampling was included to enable compressed sensing; (d) golden-angle radial-Cartesian hybrid view-ordering was incorporated to improve motion robustness; and (e) localized rigid motion correction was combined with parallel imaging compressed sensing reconstruction to reconstruct the highly accelerated wave-encoded datasets. The proposed method was tested on six subjects and image quality was compared with standard accelerated Cartesian acquisition both with and without respiratory triggering. Inverse gradient entropy and normalized gradient squared metrics were calculated, testing whether image quality was improved using paired t-tests. For respiratory-triggered scans, wave-encoding significantly reduced residual aliasing and blurring compared with standard Cartesian acquisition (metrics suggesting P < 0.05). For non-respiratory-triggered scans, the proposed method yielded significantly better motion correction compared with standard motion-corrected Cartesian acquisition (metrics suggesting P < 0.01). The proposed methods can reduce motion artifacts and improve overall image quality of highly accelerated free-breathing abdominal MRI. Magn Reson Med 78:1757-1766, 2017. © 2016 International Society for Magnetic Resonance in Medicine. © 2016 International Society for Magnetic Resonance in Medicine.

  2. Hyperpolarized 13 C,15 N2 -Urea MRI for assessment of the urea gradient in the porcine kidney.

    PubMed

    Hansen, Esben S S; Stewart, Neil J; Wild, Jim M; Stødkilde-Jørgensen, Hans; Laustsen, Christoffer

    2016-12-01

    A decline in cortico-medullary osmolality gradient of the kidney may serve as an early indicator of pathological disruption of the tubular reabsorption process. The purpose of this study was to investigate the feasibility of hyperpolarized 13 C, 15 N 2 -urea MRI as a biomarker of renal function in healthy porcine kidneys resembling the human physiology. Five healthy female Danish domestic pigs (weight 30 kg) were scanned at 3 Tesla (T) using a 13 C 3D balanced steady-state MR pulse sequence following injection of hyperpolarized 13 C, 15 N 2 -urea via a femoral vein catheter. Images were acquired at different time points after urea injection, and following treatment with furosemide. A gradient in cortico-medullary urea was observed with an intramedullary accumulation 75 s after injection of hyperpolarized 13 C, 15 N 2 -urea, whereas images acquired at earlier time points postinjection were dominated by cortical perfusion. Furosemide treatment resulted in an increased urea accumulation in the cortical space, leading to a reduction of the medullary-to-cortical signal ratio of 49%. This study demonstrates that hyperpolarized 13 C, 15 N 2 -urea MRI is capable of identifying the intrarenal accumulation of urea and can differentiate acute renal functional states in multipapillary kidneys, highlighting the potential for human translation. Magn Reson Med 76:1895-1899, 2016. © 2016 International Society for Magnetic Resonance in Medicine. © 2016 International Society for Magnetic Resonance in Medicine.

  3. Diffusion radiomics analysis of intratumoral heterogeneity in a murine prostate cancer model following radiotherapy: Pixelwise correlation with histology.

    PubMed

    Lin, Yu-Chun; Lin, Gigin; Hong, Ji-Hong; Lin, Yi-Ping; Chen, Fang-Hsin; Ng, Shu-Hang; Wang, Chun-Chieh

    2017-08-01

    To investigate the biological meaning of apparent diffusion coefficient (ADC) values in tumors following radiotherapy. Five mice bearing TRAMP-C1 tumor were half-irradiated with a dose of 15 Gy. Diffusion-weighted images, using multiple b-values from 0 to 3000 s/mm 2 , were acquired at 7T on day 6. ADC values calculated by a two-point estimate and monoexponential fitting of signal decay were compared between the irradiated and nonirradiated regions of the tumor. Pixelwise ADC maps were correlated with histological metrics including nuclear counts, nuclear sizes, nuclear spaces, cytoplasmic spaces, and extracellular spaces. As compared with the nonirradiated region, the irradiated region exhibited significant increases in ADC, extracellular space, and nuclear size, and a significant decrease in nuclear counts (P < 0.001 for all). Optimal ADC to differentiate the irradiated from nonirradiated regions was achieved at a b-value of 800 s/mm 2 by the two-point method and monoexponential curve fitting. ADC positively correlated with extracellular spaces (r = 0.74) and nuclear sizes (r = 0.72), and negatively correlated with nuclear counts (r = -0.82, P < 0.001 for all). As a radiomic biomarker, ADC maps correlating with histological metrics pixelwise could be a means of evaluating tumor heterogeneity and responses to radiotherapy. 1 Technical Efficacy: Stage 2 J. MAGN. RESON. IMAGING 2017;46:483-489. © 2017 International Society for Magnetic Resonance in Medicine.

  4. Metabolite diffusion up to very high b in the mouse brain in vivo: Revisiting the potential correlation between relaxation and diffusion properties

    PubMed Central

    Ligneul, Clémence; Palombo, Marco

    2016-01-01

    Purpose To assess the potential correlation between metabolites diffusion and relaxation in the mouse brain, which is of importance for interpreting and modeling metabolite diffusion based on pure geometry, irrespective of relaxation properties (multicompartmental relaxation or surface relaxivity). Methods A new diffusion‐weighted magnetic resonance spectroscopy sequence is introduced, dubbed “STE‐LASER,” which presents several nice properties, in particular the absence of cross‐terms with selection gradients and a very clean localization. Metabolite diffusion is then measured in a large voxel in the mouse brain at 11.7 Tesla using a cryoprobe, resulting in excellent signal‐to‐noise ratio, up to very high b‐values under different echo time, mixing time, and diffusion time combinations. Results Our results suggest that the correlation between relaxation and diffusion properties is extremely small or even nonexistent for metabolites in the mouse brain. Conclusion The present work strongly supports the interpretation and modeling of metabolite diffusion primarily based on geometry, irrespective of relaxation properties, at least under current experimental conditions. Magn Reson Med 77:1390–1398, 2017. © 2016 The Authors Magnetic Resonance in Medicine published by Wiley Periodicals, Inc. on behalf of International Society for Magnetic Resonance in Medicine. This is an open access article under the terms of the Creative Commons Attribution‐NonCommercial‐NoDerivs License, which permits use and distribution in any medium, provided the original work is properly cited, the use is non‐commercial and no modifications or adaptations are made. PMID:27018415

  5. Free-breathing volumetric fat/water separation by combining radial sampling, compressed sensing, and parallel imaging.

    PubMed

    Benkert, Thomas; Feng, Li; Sodickson, Daniel K; Chandarana, Hersh; Block, Kai Tobias

    2017-08-01

    Conventional fat/water separation techniques require that patients hold breath during abdominal acquisitions, which often fails and limits the achievable spatial resolution and anatomic coverage. This work presents a novel approach for free-breathing volumetric fat/water separation. Multiecho data are acquired using a motion-robust radial stack-of-stars three-dimensional GRE sequence with bipolar readout. To obtain fat/water maps, a model-based reconstruction is used that accounts for the off-resonant blurring of fat and integrates both compressed sensing and parallel imaging. The approach additionally enables generation of respiration-resolved fat/water maps by detecting motion from k-space data and reconstructing different respiration states. Furthermore, an extension is described for dynamic contrast-enhanced fat-water-separated measurements. Uniform and robust fat/water separation is demonstrated in several clinical applications, including free-breathing noncontrast abdominal examination of adults and a pediatric subject with both motion-averaged and motion-resolved reconstructions, as well as in a noncontrast breast exam. Furthermore, dynamic contrast-enhanced fat/water imaging with high temporal resolution is demonstrated in the abdomen and breast. The described framework provides a viable approach for motion-robust fat/water separation and promises particular value for clinical applications that are currently limited by the breath-holding capacity or cooperation of patients. Magn Reson Med 78:565-576, 2017. © 2016 International Society for Magnetic Resonance in Medicine. © 2016 International Society for Magnetic Resonance in Medicine.

  6. Interleaved EPI diffusion imaging using SPIRiT-based reconstruction with virtual coil compression.

    PubMed

    Dong, Zijing; Wang, Fuyixue; Ma, Xiaodong; Zhang, Zhe; Dai, Erpeng; Yuan, Chun; Guo, Hua

    2018-03-01

    To develop a novel diffusion imaging reconstruction framework based on iterative self-consistent parallel imaging reconstruction (SPIRiT) for multishot interleaved echo planar imaging (iEPI), with computation acceleration by virtual coil compression. As a general approach for autocalibrating parallel imaging, SPIRiT improves the performance of traditional generalized autocalibrating partially parallel acquisitions (GRAPPA) methods in that the formulation with self-consistency is better conditioned, suggesting SPIRiT to be a better candidate in k-space-based reconstruction. In this study, a general SPIRiT framework is adopted to incorporate both coil sensitivity and phase variation information as virtual coils and then is applied to 2D navigated iEPI diffusion imaging. To reduce the reconstruction time when using a large number of coils and shots, a novel shot-coil compression method is proposed for computation acceleration in Cartesian sampling. Simulations and in vivo experiments were conducted to evaluate the performance of the proposed method. Compared with the conventional coil compression, the shot-coil compression achieved higher compression rates with reduced errors. The simulation and in vivo experiments demonstrate that the SPIRiT-based reconstruction outperformed the existing method, realigned GRAPPA, and provided superior images with reduced artifacts. The SPIRiT-based reconstruction with virtual coil compression is a reliable method for high-resolution iEPI diffusion imaging. Magn Reson Med 79:1525-1531, 2018. © 2017 International Society for Magnetic Resonance in Medicine. © 2017 International Society for Magnetic Resonance in Medicine.

  7. "MASSIVE" brain dataset: Multiple acquisitions for standardization of structural imaging validation and evaluation.

    PubMed

    Froeling, Martijn; Tax, Chantal M W; Vos, Sjoerd B; Luijten, Peter R; Leemans, Alexander

    2017-05-01

    In this work, we present the MASSIVE (Multiple Acquisitions for Standardization of Structural Imaging Validation and Evaluation) brain dataset of a single healthy subject, which is intended to facilitate diffusion MRI (dMRI) modeling and methodology development. MRI data of one healthy subject (female, 25 years) were acquired on a clinical 3 Tesla system (Philips Achieva) with an eight-channel head coil. In total, the subject was scanned on 18 different occasions with a total acquisition time of 22.5 h. The dMRI data were acquired with an isotropic resolution of 2.5 mm 3 and distributed over five shells with b-values up to 4000 s/mm 2 and two Cartesian grids with b-values up to 9000 s/mm 2 . The final dataset consists of 8000 dMRI volumes, corresponding B 0 field maps and noise maps for subsets of the dMRI scans, and ten three-dimensional FLAIR, T 1 -, and T 2 -weighted scans. The average signal-to-noise-ratio of the non-diffusion-weighted images was roughly 35. This unique set of in vivo MRI data will provide a robust framework to evaluate novel diffusion processing techniques and to reliably compare different approaches for diffusion modeling. The MASSIVE dataset is made publically available (both unprocessed and processed) on www.massive-data.org. Magn Reson Med 77:1797-1809, 2017. © 2016 International Society for Magnetic Resonance in Medicine. © 2016 International Society for Magnetic Resonance in Medicine.

  8. Pseudo Steady-State Free Precession for MR-Fingerprinting.

    PubMed

    Assländer, Jakob; Glaser, Steffen J; Hennig, Jürgen

    2017-03-01

    This article discusses the signal behavior in the case the flip angle in steady-state free precession sequences is continuously varied as suggested for MR-fingerprinting sequences. Flip angle variations prevent the establishment of a steady state and introduce instabilities regarding to magnetic field inhomogeneities and intravoxel dephasing. We show how a pseudo steady state can be achieved, which restores the spin echo nature of steady-state free precession. Based on geometrical considerations, relationships between the flip angle, repetition and echo time are derived that suffice to the establishment of a pseudo steady state. The theory is tested with Bloch simulations as well as phantom and in vivo experiments. A typical steady-state free precession passband can be restored with the proposed conditions. The stability of the pseudo steady state is demonstrated by comparing the evolution of the signal of a single isochromat to one resulting from a spin ensemble. As confirmed by experiments, magnetization in a pseudo steady state can be described with fewer degrees of freedom compared to the original fingerprinting and the pseudo steady state results in more reliable parameter maps. The proposed conditions restore the spin-echo-like signal behavior typical for steady-state free precession in fingerprinting sequences, making this approach more robust to B 0 variations. Magn Reson Med 77:1151-1161, 2017. © 2016 International Society for Magnetic Resonance in Medicine. © 2016 International Society for Magnetic Resonance in Medicine.

  9. Focal point determination in magnetic resonance-guided focused ultrasound using tracking coils.

    PubMed

    Svedin, Bryant T; Beck, Michael J; Hadley, J Rock; Merrill, Robb; de Bever, Joshua T; Bolster, Bradley D; Payne, Allison; Parker, Dennis L

    2017-06-01

    To develop a method for rapid prediction of the geometric focus location in MR coordinates of a focused ultrasound (US) transducer with arbitrary position and orientation without sonicating. Three small tracker coil circuits were designed, constructed, attached to the transducer housing of a breast-specific MR-guided focused US (MRgFUS) system with 5 degrees of freedom, and connected to receiver channel inputs of an MRI scanner. A one-dimensional sequence applied in three orthogonal directions determined the position of each tracker, which was then corrected for gradient nonlinearity. In a calibration step, low-level heating located the US focus in one transducer position orientation where the tracker positions were also known. Subsequent US focus locations were determined from the isometric transformation of the trackers. The accuracy of this method was verified by comparing the tracking coil predictions to thermal center of mass calculated using MR thermometry data acquired at 16 different transducer positions for MRgFUS sonications in a homogeneous gelatin phantom. The tracker coil predicted focus was an average distance of 2.1 ± 1.1 mm from the thermal center of mass. The one-dimensional locator sequence and prediction calculations took less than 1 s to perform. This technique accurately predicts the geometric focus for a transducer with arbitrary position and orientation without sonicating. Magn Reson Med 77:2424-2430, 2017. © 2016 International Society for Magnetic Resonance in Medicine. © 2016 International Society for Magnetic Resonance in Medicine.

  10. Syndrome d'interruption de la tige pituitaire à révélation tardive

    PubMed Central

    Marmouch, Héla; Graja, Samah; Arfa, Sondes; Boubaker, Fadia; Khochtali, Ines

    2016-01-01

    Le syndrome d'interruption de la tige pituitaire est une cause assez fréquente de déficit en hormone de croissance et d'hypopituitarisme souvent révélé pendant la période néonatale et l'enfance. Cette observation illustre les particularités d'une révélation tardive de ce syndrome. Il s'agit d'une patiente âgée de 17ans hospitalisée pour aménorrhée primaire et impubérisme. Elle n'a pas d'antécédent d'incident néonatal. L'examen clinique révèle un retard de croissance sévère. L'hypophysiogramme a montré un hypopituitarisme complet sans diabète insipide. L'imagerie par résonnance magnétique a montré une interruption de la tige pituitaire avec une post hypophyse ectopique. Une malformation rénale a été objectivée, ce qui est en faveur d'une origine congénitale malformative de ce syndrome. Une substitution hormonale a été administrée à cette patiente. Cette forme clinique tardive souligne la nécessité de diagnostic précoce d'impubérisme et/ou de retard de croissance révélant une pathologie à potentiel de gravité important. PMID:27231511

  11. A time-efficient acquisition protocol for multipurpose diffusion-weighted microstructural imaging at 7 Tesla.

    PubMed

    Sepehrband, Farshid; O'Brien, Kieran; Barth, Markus

    2017-12-01

    Several diffusion-weighted MRI techniques have been developed and validated during the past 2 decades. While offering various neuroanatomical inferences, these techniques differ in their proposed optimal acquisition design, preventing clinicians and researchers benefiting from all potential inference methods, particularly when limited time is available. This study reports an optimal design that enables for a time-efficient diffusion-weighted MRI acquisition scheme at 7 Tesla. The primary audience of this article is the typical end user, interested in diffusion-weighted microstructural imaging at 7 Tesla. We tested b-values in the range of 700 to 3000 s/mm 2 with different number of angular diffusion-encoding samples, against a data-driven "gold standard." The suggested design is a protocol with b-values of 1000 and 2500 s/mm 2 , with 25 and 50 samples, uniformly distributed over two shells. We also report a range of protocols in which the results of fitting microstructural models to the diffusion-weighted data had high correlation with the gold standard. We estimated minimum acquisition requirements that enable diffusion tensor imaging, higher angular resolution diffusion-weighted imaging, neurite orientation dispersion, and density imaging and white matter tract integrity across whole brain with isotropic resolution of 1.8 mm in less than 11 min. Magn Reson Med 78:2170-2184, 2017. © 2017 International Society for Magnetic Resonance in Medicine. © 2017 International Society for Magnetic Resonance in Medicine.

  12. Imaging of the rabbit supraspinatus enthesis at 7 Tesla: a 4-week time course after repair surgery and effect of channeling.

    PubMed

    Trudel, Guy; Melkus, Gerd; Cron, Greg O; Louati, Hakim; Sheikh, Adnan; Larson, Peder E Z; Schweitzer, Mark; Lapner, Peter; Uhthoff, Hans K; Laneuville, Odette

    2017-08-01

    To image the supraspinatus enthesis reformation of rabbit shoulders by magnetic resonance at 7 Tesla (T) using T2 mapping after surgical repair and to assess the effects of channeling aimed at enhancing enthesis reformation. In 112 rabbits, the distal supraspinatus (SSP) tendon was unilaterally detached and reattached after 1 week. At the first surgery, channeling was performed at the footprint in 64 rabbits. At the second surgery, the SSP tendon of all rabbits was re-attached to the greater tuberosity. The shoulders were harvested at 0, 1, 2, or 4 weeks after the repair surgery and were imaged at 7T. Quantitative T2 mapping was performed using multi slice two-dimensional multi-echo spin-echo sequence with fat saturation. Enthesis regions of interests were drawn on three slices at the footprint to measure T2 relaxation times. Tendon repair (F (2, 218)  = 44; P < 2.2e-16) and postoperative duration (F (3, 218)  = 4.8; P = 0.006) both affected significantly the T2 values while channeling had no significant effect. For the time effect, the only pair with a statistical difference was the 0-week and 4-week for the channeling groups (P = 0.023). Enthesis reformation early after surgical repair of the SSP distal tendon was characterized by increasing T2 values. 2 Technical Efficacy: Stage 1 J. MAGN. RESON. IMAGING 2017;46:461-467. © 2017 International Society for Magnetic Resonance in Medicine.

  13. Hepatic function imaging using dynamic Gd-EOB-DTPA enhanced MRI and pharmacokinetic modeling.

    PubMed

    Ning, Jia; Yang, Zhiying; Xie, Sheng; Sun, Yongliang; Yuan, Chun; Chen, Huijun

    2017-10-01

    To determine whether pharmacokinetic modeling parameters with different output assumptions of dynamic contrast-enhanced MRI (DCE-MRI) using Gd-EOB-DTPA correlate with serum-based liver function tests, and compare the goodness of fit of the different output assumptions. A 6-min DCE-MRI protocol was performed in 38 patients. Four dual-input two-compartment models with different output assumptions and a published one-compartment model were used to calculate hepatic function parameters. The Akaike information criterion fitting error was used to evaluate the goodness of fit. Imaging-based hepatic function parameters were compared with blood chemistry using correlation with multiple comparison correction. The dual-input two-compartment model assuming venous flow equals arterial flow plus portal venous flow and no bile duct output better described the liver tissue enhancement with low fitting error and high correlation with blood chemistry. The relative uptake rate Kir derived from this model was found to be significantly correlated with direct bilirubin (r = -0.52, P = 0.015), prealbumin concentration (r = 0.58, P = 0.015), and prothrombin time (r = -0.51, P = 0.026). It is feasible to evaluate hepatic function by proper output assumptions. The relative uptake rate has the potential to serve as a biomarker of function. Magn Reson Med 78:1488-1495, 2017. © 2016 International Society for Magnetic Resonance in Medicine. © 2016 International Society for Magnetic Resonance in Medicine.

  14. Simultaneous acquisition sequence for improved hepatic pharmacokinetics quantification accuracy (SAHA) for dynamic contrast-enhanced MRI of liver.

    PubMed

    Ning, Jia; Sun, Yongliang; Xie, Sheng; Zhang, Bida; Huang, Feng; Koken, Peter; Smink, Jouke; Yuan, Chun; Chen, Huijun

    2018-05-01

    To propose a simultaneous acquisition sequence for improved hepatic pharmacokinetics quantification accuracy (SAHA) method for liver dynamic contrast-enhanced MRI. The proposed SAHA simultaneously acquired high temporal-resolution 2D images for vascular input function extraction using Cartesian sampling and 3D large-coverage high spatial-resolution liver dynamic contrast-enhanced images using golden angle stack-of-stars acquisition in an interleaved way. Simulations were conducted to investigate the accuracy of SAHA in pharmacokinetic analysis. A healthy volunteer and three patients with cirrhosis or hepatocellular carcinoma were included in the study to investigate the feasibility of SAHA in vivo. Simulation studies showed that SAHA can provide closer results to the true values and lower root mean square error of estimated pharmacokinetic parameters in all of the tested scenarios. The in vivo scans of subjects provided fair image quality of both 2D images for arterial input function and portal venous input function and 3D whole liver images. The in vivo fitting results showed that the perfusion parameters of healthy liver were significantly different from those of cirrhotic liver and HCC. The proposed SAHA can provide improved accuracy in pharmacokinetic modeling and is feasible in human liver dynamic contrast-enhanced MRI, suggesting that SAHA is a potential tool for liver dynamic contrast-enhanced MRI. Magn Reson Med 79:2629-2641, 2018. © 2017 International Society for Magnetic Resonance in Medicine. © 2017 International Society for Magnetic Resonance in Medicine.

  15. Decoupling of a tight-fit transceiver phased array for human brain imaging at 9.4T: Loop overlapping rediscovered.

    PubMed

    Avdievich, Nikolai I; Giapitzakis, Ioannis-Angelos; Pfrommer, Andreas; Henning, Anke

    2018-02-01

    To improve the decoupling of a transceiver human head phased array at ultra-high fields (UHF, ≥ 7T) and to optimize its transmit (Tx) and receive (Rx) performance, a single-row eight-element (1 × 8) tight-fit transceiver overlapped loop array was developed and constructed. Overlapping the loops increases the RF field penetration depth but can compromise decoupling by generating substantial mutual resistance. Based on analytical modeling, we optimized the loop geometry and relative positioning to simultaneously minimize the resistive and inductive coupling and constructed a 9.4T eight-loop transceiver head phased array decoupled entirely by overlapping loops. We demonstrated that both the magnetic and electric coupling between adjacent loops is compensated at the same time by overlapping and nearly perfect decoupling (below -30 dB) can be obtained without additional decoupling strategies. Tx-efficiency and SNR of the overlapped array outperformed that of a common UHF gapped array of similar dimensions. Parallel Rx-performance was also not compromised due to overlapping the loops. As a proof of concept we developed and constructed a 9.4T (400 MHz) overlapped transceiver head array based on results of the analytical modeling. We demonstrated that at UHF overlapping loops not only provides excellent decoupling but also improves both Tx- and Rx-performance. Magn Reson Med 79:1200-1211, 2018. © 2017 International Society for Magnetic Resonance in Medicine. © 2017 International Society for Magnetic Resonance in Medicine.

  16. Constrained optimization for position calibration of an NMR field camera.

    PubMed

    Chang, Paul; Nassirpour, Sahar; Eschelbach, Martin; Scheffler, Klaus; Henning, Anke

    2018-07-01

    Knowledge of the positions of field probes in an NMR field camera is necessary for monitoring the B 0 field. The typical method of estimating these positions is by switching the gradients with known strengths and calculating the positions using the phases of the FIDs. We investigated improving the accuracy of estimating the probe positions and analyzed the effect of inaccurate estimations on field monitoring. The field probe positions were estimated by 1) assuming ideal gradient fields, 2) using measured gradient fields (including nonlinearities), and 3) using measured gradient fields with relative position constraints. The fields measured with the NMR field camera were compared to fields acquired using a dual-echo gradient recalled echo B 0 mapping sequence. Comparisons were done for shim fields from second- to fourth-order shim terms. The position estimation was the most accurate when relative position constraints were used in conjunction with measured (nonlinear) gradient fields. The effect of more accurate position estimates was seen when compared to fields measured using a B 0 mapping sequence (up to 10%-15% more accurate for some shim fields). The models acquired from the field camera are sensitive to noise due to the low number of spatial sample points. Position estimation of field probes in an NMR camera can be improved using relative position constraints and nonlinear gradient fields. Magn Reson Med 80:380-390, 2018. © 2017 International Society for Magnetic Resonance in Medicine. © 2017 International Society for Magnetic Resonance in Medicine.

  17. Coil compression in simultaneous multislice functional MRI with concentric ring slice-GRAPPA and SENSE.

    PubMed

    Chu, Alan; Noll, Douglas C

    2016-10-01

    Simultaneous multislice (SMS) imaging is a useful way to accelerate functional magnetic resonance imaging (fMRI). As acceleration becomes more aggressive, an increasingly larger number of receive coils are required to separate the slices, which significantly increases the computational burden. We propose a coil compression method that works with concentric ring non-Cartesian SMS imaging and should work with Cartesian SMS as well. We evaluate the method on fMRI scans of several subjects and compare it to standard coil compression methods. The proposed method uses a slice-separation k-space kernel to simultaneously compress coil data into a set of virtual coils. Five subjects were scanned using both non-SMS fMRI and SMS fMRI with three simultaneous slices. The SMS fMRI scans were processed using the proposed method, along with other conventional methods. Code is available at https://github.com/alcu/sms. The proposed method maintained functional activation with a fewer number of virtual coils than standard SMS coil compression methods. Compression of non-SMS fMRI maintained activation with a slightly lower number of virtual coils than the proposed method, but does not have the acceleration advantages of SMS fMRI. The proposed method is a practical way to compress and reconstruct concentric ring SMS data and improves the preservation of functional activation over standard coil compression methods in fMRI. Magn Reson Med 76:1196-1209, 2016. © 2015 Wiley Periodicals, Inc. © 2015 Wiley Periodicals, Inc.

  18. Resting-state functional MRI as a tool for evaluating brain hemodynamic responsiveness to external stimuli in rats.

    PubMed

    Paasonen, Jaakko; Salo, Raimo A; Huttunen, Joanna K; Gröhn, Olli

    2017-09-01

    Anesthesia is a major confounding factor in functional MRI (fMRI) experiments attributed to its effects on brain function. Recent evidence suggests that parameters obtained with resting-state fMRI (rs-fMRI) are coupled with anesthetic depth. Therefore, we investigated whether parameters obtained with rs-fMRI, such as functional connectivity (FC), are also directly related to blood-oxygen-level-dependent (BOLD) responses. A simple rs-fMRI protocol was implemented in a pharmacological fMRI study to evaluate the coupling between hemodynamic responses and FC under five anesthetics (α-chloralose, isoflurane, medetomidine, thiobutabarbital, and urethane). Temporal change in the FC was evaluated at 1-hour interval. Supplementary forepaw stimulation experiments were also conducted. Under thiobutabarbital anesthesia, FC was clearly coupled with nicotine-induced BOLD responses. Good correlation values were also obtained under isoflurane and medetomidine anesthesia. The observations in the thiobutabarbital group were supported by forepaw stimulation experiments. Additionally, the rs-fMRI protocol revealed significant temporal changes in the FC in the α-chloralose, thiobutabarbital, and urethane groups. Our results suggest that FC can be used to estimate brain hemodynamic responsiveness to stimuli and evaluate the level and temporal changes of anesthesia. Therefore, analysis of the fMRI baseline signal may be highly valuable tool for controlling the outcome of preclinical fMRI experiments. Magn Reson Med 78:1136-1146, 2017. © 2016 International Society for Magnetic Resonance in Medicine. © 2016 International Society for Magnetic Resonance in Medicine.

  19. LORAKS makes better SENSE: Phase-constrained partial fourier SENSE reconstruction without phase calibration.

    PubMed

    Kim, Tae Hyung; Setsompop, Kawin; Haldar, Justin P

    2017-03-01

    Parallel imaging and partial Fourier acquisition are two classical approaches for accelerated MRI. Methods that combine these approaches often rely on prior knowledge of the image phase, but the need to obtain this prior information can place practical restrictions on the data acquisition strategy. In this work, we propose and evaluate SENSE-LORAKS, which enables combined parallel imaging and partial Fourier reconstruction without requiring prior phase information. The proposed formulation is based on combining the classical SENSE model for parallel imaging data with the more recent LORAKS framework for MR image reconstruction using low-rank matrix modeling. Previous LORAKS-based methods have successfully enabled calibrationless partial Fourier parallel MRI reconstruction, but have been most successful with nonuniform sampling strategies that may be hard to implement for certain applications. By combining LORAKS with SENSE, we enable highly accelerated partial Fourier MRI reconstruction for a broader range of sampling trajectories, including widely used calibrationless uniformly undersampled trajectories. Our empirical results with retrospectively undersampled datasets indicate that when SENSE-LORAKS reconstruction is combined with an appropriate k-space sampling trajectory, it can provide substantially better image quality at high-acceleration rates relative to existing state-of-the-art reconstruction approaches. The SENSE-LORAKS framework provides promising new opportunities for highly accelerated MRI. Magn Reson Med 77:1021-1035, 2017. © 2016 International Society for Magnetic Resonance in Medicine. © 2016 International Society for Magnetic Resonance in Medicine.

  20. Partial Fourier techniques in single-shot cross-term spatiotemporal encoded MRI.

    PubMed

    Zhang, Zhiyong; Frydman, Lucio

    2018-03-01

    Cross-term spatiotemporal encoding (xSPEN) is a single-shot approach with exceptional immunity to field heterogeneities, the images of which faithfully deliver 2D spatial distributions without requiring a priori information or using postacquisition corrections. xSPEN, however, suffers from signal-to-noise ratio penalties due to its non-Fourier nature and due to diffusion losses-especially when seeking high resolution. This study explores partial Fourier transform approaches that, acting along either the readout or the spatiotemporally encoded dimensions, reduce these penalties. xSPEN uses an orthogonal (e.g., z) gradient to read, in direct space, the low-bandwidth (e.g., y) dimension. This substantially changes the nature of partial Fourier acquisitions vis-à-vis conventional imaging counterparts. A suitable theoretical analysis is derived to implement these procedures, along either the spatiotemporally or readout axes. Partial Fourier single-shot xSPEN images were recorded on preclinical and human scanners. Owing to their reduction in the experiments' acquisition times, this approach provided substantial sensitivity gains vis-à-vis previous implementations for a given targeted in-plane resolution. The physical origins of these gains are explained. Partial Fourier approaches, particularly when implemented along the low-bandwidth spatiotemporal dimension, provide several-fold sensitivity advantages at minimal costs to the execution and processing of the single-shot experiments. Magn Reson Med 79:1506-1514, 2018. © 2017 International Society for Magnetic Resonance in Medicine. © 2017 International Society for Magnetic Resonance in Medicine.

  1. Whole-body continuously moving table fat-water MRI with dynamic B0 shimming at 3 Tesla.

    PubMed

    Sengupta, Saikat; Smith, David S; Gifford, Aliya; Welch, E Brian

    2016-07-01

    The purpose of this work was to develop a rapid and robust whole-body fat-water MRI (FWMRI) method using a continuously moving table (CMT) with dynamic field corrections at 3 Tesla. CMT FWMRI was developed at 3 Tesla with a multiecho golden angle (GA) radial trajectory and dynamic B0 field shimming. Whole-body imaging was performed with 4 echoes and superior-inferior coverage of 1.8 meters without shims in 90 s. 716 axial images were reconstructed with GA profile binning followed by B0 field map generation using fast three-point seeded region growing fat-water separation and slice-specific 0(th) and 1(st) order shim calculation. Slice-specific shims were applied dynamically in a repeated CMT FWMRI scan in the same session. The resulting images were evaluated for field homogeneity improvements and quality of fat-water separation with a whole-image energy optimized algorithm. GA sampling allowed high quality whole-body FWMRI from multiecho CMT data. Dynamic B0 shimming greatly improved field homogeneity in the body and produced high quality water and fat only images as well as fat signal fraction and R2 * relaxivity maps. A rapid and robust technique for whole-body fat-water quantification has been developed with CMT MRI with dynamic B0 field correction. Magn Reson Med 76:183-190, 2016. © 2015 Wiley Periodicals, Inc. © 2015 Wiley Periodicals, Inc.

  2. Oxidation of [U-13 C]glucose in the human brain at 7T under steady state conditions.

    PubMed

    Cheshkov, Sergey; Dimitrov, Ivan E; Jakkamsetti, Vikram; Good, Levi; Kelly, Dorothy; Rajasekaran, Karthik; DeBerardinis, Ralph J; Pascual, Juan M; Sherry, A Dean; Malloy, Craig R

    2017-12-01

    Disorders of brain energy metabolism and neurotransmitter recycling have been implicated in multiple neurological conditions. 13 C magnetic resonance spectroscopy ( 13 C MRS) during intravenous administration of 13 C-labeled compounds has been used to measure turnover rates of brain metabolites. This approach, however, requires prolonged infusion inside the magnet. Proton decoupling is typically required but may be difficult to implement with standard equipment. We examined an alternative approach to monitor glucose metabolism in the human brain. 13 C-enriched glucose was infused in healthy subjects outside the magnet to a steady-state level of 13 C enrichment. Subsequently, the subjects were scanned at 7T for 60 min without 1 H decoupling. Metabolic modeling was used to calculate anaplerosis. Biomarkers of energy metabolism and anaplerosis were detected. The glutamate C5 doublet provided information about glucose-derived acetyl-coenzyme A flux into the tricarboxylic acid (TCA) cycle via pyruvate dehydrogenase, and the bicarbonate signal reflected overall TCA cycle activity. The glutamate C1/C5 ratio is sensitive to anaplerosis. Brain 13 C MRS at 7T provides information about glucose oxidation and anaplerosis without the need of prolonged 13 C infusions inside the scanner and without technical challenges of 1 H decoupling, making it a feasible approach for clinical research. Magn Reson Med 78:2065-2071, 2017. © 2017 International Society for Magnetic Resonance in Medicine. © 2017 International Society for Magnetic Resonance in Medicine.

  3. A comparison of exogenous and endogenous CEST MRI methods for evaluating in vivo pH.

    PubMed

    Lindeman, Leila R; Randtke, Edward A; High, Rachel A; Jones, Kyle M; Howison, Christine M; Pagel, Mark D

    2018-05-01

    Extracellular pH (pHe) is an important biomarker for cancer cell metabolism. Acido-chemical exchange saturation transfer (CEST) MRI uses the contrast agent iopamidol to create spatial maps of pHe. Measurements of amide proton transfer exchange rates (k ex ) from endogenous CEST MRI were compared to pHe measurements by exogenous acido-CEST MRI to determine whether endogenous k ex could be used as a proxy for pHe measurements. Spatial maps of pHe and k ex were obtained using exogenous acidoCEST MRI and an endogenous CEST MRI analyzed with the omega plot method, respectively, to evaluate mouse kidney, a flank tumor model, and a spontaneous lung tumor model. The pHe and k ex results were evaluated using pixelwise comparisons. The k ex values obtained from endogenous CEST measurements did not correlate with the pHe results from exogenous CEST measurements. The k ex measurements were limited to fewer pixels and had a limited dynamic range relative to pHe measurements. Measurements of k ex with endogenous CEST MRI cannot substitute for pHe measurements with acidoCEST MRI. Whereas endogenous CEST MRI may still have good utility for evaluating some specific pathologies, exogenous acido-CEST MRI is more appropriate when evaluating pathologies based on pHe values. Magn Reson Med 79:2766-2772, 2018. © 2017 International Society for Magnetic Resonance in Medicine. © 2017 International Society for Magnetic Resonance in Medicine.

  4. Self-calibrated correlation imaging with k-space variant correlation functions.

    PubMed

    Li, Yu; Edalati, Masoud; Du, Xingfu; Wang, Hui; Cao, Jie J

    2018-03-01

    Correlation imaging is a previously developed high-speed MRI framework that converts parallel imaging reconstruction into the estimate of correlation functions. The presented work aims to demonstrate this framework can provide a speed gain over parallel imaging by estimating k-space variant correlation functions. Because of Fourier encoding with gradients, outer k-space data contain higher spatial-frequency image components arising primarily from tissue boundaries. As a result of tissue-boundary sparsity in the human anatomy, neighboring k-space data correlation varies from the central to the outer k-space. By estimating k-space variant correlation functions with an iterative self-calibration method, correlation imaging can benefit from neighboring k-space data correlation associated with both coil sensitivity encoding and tissue-boundary sparsity, thereby providing a speed gain over parallel imaging that relies only on coil sensitivity encoding. This new approach is investigated in brain imaging and free-breathing neonatal cardiac imaging. Correlation imaging performs better than existing parallel imaging techniques in simulated brain imaging acceleration experiments. The higher speed enables real-time data acquisition for neonatal cardiac imaging in which physiological motion is fast and non-periodic. With k-space variant correlation functions, correlation imaging gives a higher speed than parallel imaging and offers the potential to image physiological motion in real-time. Magn Reson Med 79:1483-1494, 2018. © 2017 International Society for Magnetic Resonance in Medicine. © 2017 International Society for Magnetic Resonance in Medicine.

  5. Critical current simulation in granular superconductors above the percolation threshold

    NASA Astrophysics Data System (ADS)

    Riedinger, Roland

    1992-02-01

    In the phase-coherent regime without applied external magnetic field, the critical superconducting current is limited by intragranular junctions which behave like Josephson junctions. We study the percolation aspects specific to lattices of such junctions and/or the mixing of superconductor with normal grains by averaging over configurations. We illustrate on 2 and 3 dimensional examples. The power laws valid near the percolation threshold are valid well above it, in two and three dimensions. We discuss the other models limiting the superconducting current, the vortex creep and superconducting order parameter fluctuations. Dans la limite de champ magnétique nul et de cohérence de phase du paramètre d'ordre supraconducteur, le courant supraconducteur maximal dans un réseau est limité par les jonctions intergranulaires qui se comportent comme des jonctions Josephson. Nous analysons les problèmes de percolation spécifiques aux réseaux de jonctions et du mélange de grains normaux et supraconducteurs. Nous donnons des exemples bidimensionnels et tridimensionnels ; après moyenne sur les configurations et analyse en taille finie, nous montrons que les lois de puissance valables au voisinage du seuil de percolation s'étendent sur un grand domaine au-delà du seuil de percolation, à deux et trois dimensions. Nous discutons les autres modèles limitant le courant supraconducteur, ancrage de vortex et fluctuations du paramètre d'ordre.

  6. Upper critical field measurements in high-Tc superconducting oxides

    NASA Astrophysics Data System (ADS)

    Ousset, J. C.; Bobo, J. F.; Ulmet, J. P.; Rakoto, H.; Cheggour, N.

    We present upper critical field measurements on the superconducting oxides RE Ba2Cu3O7-δ (RE = Y, Gd) performed in a pulsed magnetic field up to 43 T. Values for Hc2 as high as 52 T and 77 T for Y and Gd respectively, are expected at 77 K. However, in order to observe no resistive behaviour up to 43 T the temperature must be decreased down to 50 K. In the case of oxygen deficient systems the magnetoresistance reveals two superconducting phases wich could be related to two different orders of oxygen vacancies. Nous présentons des mesures de champ critique Hc2 sur les supraconducteurs TR Ba 2Cu3O7-δ (TR = Y, Gd) réalisées en champ magnétique pulsé jusqu'à 43 T. Elles permettent de prévoir des valeurs de H c2 de 52 T et 77 T respectivement pour Y et Gd à 77 K. Cependant, pour ne pas observer de comportement résistif jusqu'au champ maximum, il est nécessaire de refroidir l'échantillon jusqu'à 50 K. Dans le cas des systèmes déficients en oxygène (δ important) nous mettons en évidence l'existence de deux phases supraconductrices qui pourraient être dues à deux ordres différents des lacunes d'oxygène.

  7. Influence des traitements thermiques et de la microstructure sur les phénomènes de découplage dans les composés au bismuth

    NASA Astrophysics Data System (ADS)

    Nicolas, M.; Guyen van Huong, C. N.; Burger, J. P.; Dubon, A.; Fitoussi, J. P.; Laval, J. Y.

    1991-11-01

    a.c. susceptibility measurements and 3D electronic microscopy observation were carried out on three Bi-compounds (2212 and 2223). Depending on the annealing conditions, one observes lamellar-type materials organized either in a more or less dense structure of fine particles or in very large slabs. The a.c. susceptibility signals allow to separate the intergranular from the intragranular effects. The combined results obtained by both techniques lead us to conclude that the intergranular and the intragranular decoupling, induced by magnetic fields are of same nature, i.e. occur at the (BiO)2 slab. Nous avons couplé des mesures de susceptibilité altemative et d'observation au microscope électronique en 3D sur trois échantillons supraconducteurs au bismuth (2212 et 2223). Selon les conditions de recuit, on observe des matériaux de type lamellaire, organisés soit en une structure plus ou moins dense de fines particules, soit en larges plaquettes. L'étude des signaux de susceptibilité alternative χ' et χ'' permet de séparer les effets intergranulaires des effets intragranulaires. les résultats combinés des deux techniques nous ont conduit à conclure que les deux types de découplage (inter et intragranulaires), induits par les champs magnétiques sont de même nature, c'est-à-dire se produisent au niveau des bicouches (BiO)2.

  8. Synthesized tissue-equivalent dielectric phantoms using salt and polyvinylpyrrolidone solutions.

    PubMed

    Ianniello, Carlotta; de Zwart, Jacco A; Duan, Qi; Deniz, Cem M; Alon, Leeor; Lee, Jae-Seung; Lattanzi, Riccardo; Brown, Ryan

    2018-07-01

    To explore the use of polyvinylpyrrolidone (PVP) for simulated materials with tissue-equivalent dielectric properties. PVP and salt were used to control, respectively, relative permittivity and electrical conductivity in a collection of 63 samples with a range of solute concentrations. Their dielectric properties were measured with a commercial probe and fitted to a 3D polynomial in order to establish an empirical recipe. The material's thermal properties and MR spectra were measured. The empirical polynomial recipe (available at https://www.amri.ninds.nih.gov/cgi-bin/phantomrecipe) provides the PVP and salt concentrations required for dielectric materials with permittivity and electrical conductivity values between approximately 45 and 78, and 0.1 to 2 siemens per meter, respectively, from 50 MHz to 4.5 GHz. The second- (solute concentrations) and seventh- (frequency) order polynomial recipe provided less than 2.5% relative error between the measured and target properties. PVP side peaks in the spectra were minor and unaffected by temperature changes. PVP-based phantoms are easy to prepare and nontoxic, and their semitransparency makes air bubbles easy to identify. The polymer can be used to create simulated material with a range of dielectric properties, negligible spectral side peaks, and long T 2 relaxation time, which are favorable in many MR applications. Magn Reson Med 80:413-419, 2018. © 2017 International Society for Magnetic Resonance in Medicine. © 2017 International Society for Magnetic Resonance in Medicine.

  9. Thermoelectric properties of in-situ plasma spray synthesized sub-stoichiometry TiO 2-x

    DOE PAGES

    Lee, Hwasoo; Han, Su Jung; Seshadri, Ramachandran Chidambaram; ...

    2016-11-04

    The thermoelectric properties of sub-stoichiometric TiO 2-x deposits produced by cascaded-plasma spray process are investigated from room-temperature to 750 K. Sub-stoichiometric TiO 2-x deposits are formed through in-situ reaction of the TiO 1.9 within the high temperature plasma flame and manipulated through introduction of varying amounts of hydrogen in the plasma. Although the TiO 2-x particles experience reduction within plasma, it can also re-oxidize through interaction with the surrounding ambient atmosphere, resulting in a complex interplay between process conditions and stoichiometry. The deposits predominantly contain rutile phase with presence of Magneli phases especially under significantly reducing plasma conditions. The resultantmore » deposits show sensitivity to thermoelectric properties and under certain optimal conditions repeatedly show Seebeck coefficients reaching values of -230 μV K -1 at temperatures of 750 K while providing an electrical conductivity of 5.48 × 10 3 S m -1, relatively low thermal conductivity in the range of 1.5 to 2 W m -1 K -1 resulting in power factor of 2.9 μW cm -1 K -2. The resultant maximum thermoelectric figure of merit value reached 0.132 under these optimal conditions. Lastly, the results point to a potential pathway for a large-scale fabrication of low-cost oxide based thermoelectric with potential applicability at moderate to high temperatures.« less

  10. Ultra wideband (0.5-16 kHz) MR elastography for robust shear viscoelasticity model identification.

    PubMed

    Liu, Yifei; Yasar, Temel K; Royston, Thomas J

    2014-12-21

    Changes in the viscoelastic parameters of soft biological tissues often correlate with progression of disease, trauma or injury, and response to treatment. Identifying the most appropriate viscoelastic model, then estimating and monitoring the corresponding parameters of that model can improve insight into the underlying tissue structural changes. MR Elastography (MRE) provides a quantitative method of measuring tissue viscoelasticity. In a previous study by the authors (Yasar et al 2013 Magn. Reson. Med. 70 479-89), a silicone-based phantom material was examined over the frequency range of 200 Hz-7.75 kHz using MRE, an unprecedented bandwidth at that time. Six viscoelastic models including four integer order models and two fractional order models, were fit to the wideband viscoelastic data (measured storage and loss moduli as a function of frequency). The 'fractional Voigt' model (spring and springpot in parallel) exhibited the best fit and was even able to fit the entire frequency band well when it was identified based only on a small portion of the band. This paper is an extension of that study with a wider frequency range from 500 Hz to 16 kHz. Furthermore, more fractional order viscoelastic models are added to the comparison pool. It is found that added complexity of the viscoelastic model provides only marginal improvement over the 'fractional Voigt' model. And, again, the fractional order models show significant improvement over integer order viscoelastic models that have as many or more fitting parameters.

  11. Three-dimensional quantification of vorticity and helicity from 3D cine PC-MRI using finite-element interpolations.

    PubMed

    Sotelo, Julio; Urbina, Jesús; Valverde, Israel; Mura, Joaquín; Tejos, Cristián; Irarrazaval, Pablo; Andia, Marcelo E; Hurtado, Daniel E; Uribe, Sergio

    2018-01-01

    We propose a 3D finite-element method for the quantification of vorticity and helicity density from 3D cine phase-contrast (PC) MRI. By using a 3D finite-element method, we seamlessly estimate velocity gradients in 3D. The robustness and convergence were analyzed using a combined Poiseuille and Lamb-Ossen equation. A computational fluid dynamics simulation was used to compared our method with others available in the literature. Additionally, we computed 3D maps for different 3D cine PC-MRI data sets: phantom without and with coarctation (18 healthy volunteers and 3 patients). We found a good agreement between our method and both the analytical solution of the combined Poiseuille and Lamb-Ossen. The computational fluid dynamics results showed that our method outperforms current approaches to estimate vorticity and helicity values. In the in silico model, we observed that for a tetrahedral element of 2 mm of characteristic length, we underestimated the vorticity in less than 5% with respect to the analytical solution. In patients, we found higher values of helicity density in comparison to healthy volunteers, associated with vortices in the lumen of the vessels. We proposed a novel method that provides entire 3D vorticity and helicity density maps, avoiding the used of reformatted 2D planes from 3D cine PC-MRI. Magn Reson Med 79:541-553, 2018. © 2017 International Society for Magnetic Resonance in Medicine. © 2017 International Society for Magnetic Resonance in Medicine.

  12. A survey on abnormal uterine bleeding among radiographers with frequent MRI exposure using intrauterine contraceptive devices.

    PubMed

    Huss, A; Schaap, K; Kromhout, H

    2018-02-01

    Based on a previous case report of menometrorrhagia (prolonged/excessive uterine bleeding, occurring at irregular and/or frequent intervals) in MRI workers with intrauterine devices (IUDs), it was evaluated whether this association could be confirmed. A survey was performed among 381 female radiographers registered with their national association. Logistic regression was used to analyze associations of abnormal uterine bleeding with the frequency of working with MRI scanners, presence near the scanner/in the scanner room during image acquisition, and with scanner strength or type. A total of 68 women reported using IUDs, and 72 reported abnormal uterine bleeding. Compared with unexposed women not using IUDs, the odds ratio in women with IUDs working with MRI scanners was 2.09 (95% confidence interval 0.83-3.66). Associations were stronger if women working with MRI reported being present during image acquisition (odds ratio 3.43, 95% CI 1.26-9.34). Associations with scanner strength or type were not consistent. Radiographers using IUDs who are occupationally exposed to stray fields from MRI scanners report abnormal uterine bleeding more often than their co-workers without an IUD, or nonexposed co-workers with an IUD. In particular, radiographers present inside the scanner room during image acquisition showed an increased risk. Magn Reson Med 79:1083-1089, 2018. © 2017 International Society for Magnetic Resonance in Medicine. © 2017 International Society for Magnetic Resonance in Medicine.

  13. Myocardial effective transverse relaxation time T2* Correlates with left ventricular wall thickness: A 7.0 T MRI study.

    PubMed

    Huelnhagen, Till; Hezel, Fabian; Serradas Duarte, Teresa; Pohlmann, Andreas; Oezerdem, Celal; Flemming, Bert; Seeliger, Erdmann; Prothmann, Marcel; Schulz-Menger, Jeanette; Niendorf, Thoralf

    2017-06-01

    Myocardial effective relaxation time T2* is commonly regarded as a surrogate for myocardial tissue oxygenation. However, it is legitimate to assume that there are multiple factors that influence T2*. To this end, this study investigates the relationship between T2* and cardiac macromorphology given by left ventricular (LV) wall thickness and left ventricular radius, and provides interpretation of the results in the physiological context. High spatio-temporally resolved myocardial CINE T2* mapping was performed in 10 healthy volunteers using a 7.0 Tesla (T) full-body MRI system. Ventricular septal wall thickness, left ventricular inner radius, and T2* were analyzed. Macroscopic magnetic field changes were elucidated using cardiac phase-resolved magnetic field maps. Ventricular septal T2* changes periodically over the cardiac cycle, increasing in systole and decreasing in diastole. Ventricular septal wall thickness and T2* showed a significant positive correlation, whereas the inner LV radius and T2* were negatively correlated. The effect of macroscopic magnetic field gradients on T2* can be considered minor in the ventricular septum. Our findings suggest that myocardial T2* is related to tissue blood volume fraction. Temporally resolved T2* mapping could be beneficial for myocardial tissue characterization and for understanding cardiac (patho)physiology in vivo. Magn Reson Med 77:2381-2389, 2017. © 2016 International Society for Magnetic Resonance in Medicine. © 2016 International Society for Magnetic Resonance in Medicine.

  14. Assessment of Reynolds stress components and turbulent pressure loss using 4D flow MRI with extended motion encoding.

    PubMed

    Haraldsson, Henrik; Kefayati, Sarah; Ahn, Sinyeob; Dyverfeldt, Petter; Lantz, Jonas; Karlsson, Matts; Laub, Gerhard; Ebbers, Tino; Saloner, David

    2018-04-01

    To measure the Reynolds stress tensor using 4D flow MRI, and to evaluate its contribution to computed pressure maps. A method to assess both velocity and Reynolds stress using 4D flow MRI is presented and evaluated. The Reynolds stress is compared by cross-sectional integrals of the Reynolds stress invariants. Pressure maps are computed using the pressure Poisson equation-both including and neglecting the Reynolds stress. Good agreement is seen for Reynolds stress between computational fluid dynamics, simulated MRI, and MRI experiment. The Reynolds stress can significantly influence the computed pressure loss for simulated (eg, -0.52% vs -15.34% error; P < 0.001) and experimental (eg, 306 ± 11 vs 203 ± 6 Pa; P < 0.001) data. A 54% greater pressure loss is seen at the highest experimental flow rate when accounting for Reynolds stress (P < 0.001). 4D flow MRI with extended motion-encoding enables quantification of both the velocity and the Reynolds stress tensor. The additional information provided by this method improves the assessment of pressure gradients across a stenosis in the presence of turbulence. Unlike conventional methods, which are only valid if the flow is laminar, the proposed method is valid for both laminar and disturbed flow, a common presentation in diseased vessels. Magn Reson Med 79:1962-1971, 2018. © 2017 International Society for Magnetic Resonance in Medicine. © 2017 International Society for Magnetic Resonance in Medicine.

  15. Thermoelectric properties of in-situ plasma spray synthesized sub-stoichiometry TiO 2-x

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Lee, Hwasoo; Han, Su Jung; Seshadri, Ramachandran Chidambaram

    The thermoelectric properties of sub-stoichiometric TiO 2-x deposits produced by cascaded-plasma spray process are investigated from room-temperature to 750 K. Sub-stoichiometric TiO 2-x deposits are formed through in-situ reaction of the TiO 1.9 within the high temperature plasma flame and manipulated through introduction of varying amounts of hydrogen in the plasma. Although the TiO 2-x particles experience reduction within plasma, it can also re-oxidize through interaction with the surrounding ambient atmosphere, resulting in a complex interplay between process conditions and stoichiometry. The deposits predominantly contain rutile phase with presence of Magneli phases especially under significantly reducing plasma conditions. The resultantmore » deposits show sensitivity to thermoelectric properties and under certain optimal conditions repeatedly show Seebeck coefficients reaching values of -230 μV K -1 at temperatures of 750 K while providing an electrical conductivity of 5.48 × 10 3 S m -1, relatively low thermal conductivity in the range of 1.5 to 2 W m -1 K -1 resulting in power factor of 2.9 μW cm -1 K -2. The resultant maximum thermoelectric figure of merit value reached 0.132 under these optimal conditions. Lastly, the results point to a potential pathway for a large-scale fabrication of low-cost oxide based thermoelectric with potential applicability at moderate to high temperatures.« less

  16. Thermoelectric properties of in-situ plasma spray synthesized sub-stoichiometry TiO2-x.

    PubMed

    Lee, Hwasoo; Han, Su Jung; Chidambaram Seshadri, Ramachandran; Sampath, Sanjay

    2016-11-04

    The thermoelectric properties of sub-stoichiometric TiO 2-x deposits produced by cascaded-plasma spray process are investigated from room-temperature to 750 K. Sub-stoichiometric TiO 2-x deposits are formed through in-situ reaction of the TiO 1.9 within the high temperature plasma flame and manipulated through introduction of varying amounts of hydrogen in the plasma. Although the TiO 2-x particles experience reduction within plasma, it can also re-oxidize through interaction with the surrounding ambient atmosphere, resulting in a complex interplay between process conditions and stoichiometry. The deposits predominantly contain rutile phase with presence of Magneli phases especially under significantly reducing plasma conditions. The resultant deposits show sensitivity to thermoelectric properties and under certain optimal conditions repeatedly show Seebeck coefficients reaching values of -230 μV K -1 at temperatures of 750 K while providing an electrical conductivity of 5.48 × 10 3  S m -1 , relatively low thermal conductivity in the range of 1.5 to 2 W m -1 K -1 resulting in power factor of 2.9 μW cm -1 K -2 . The resultant maximum thermoelectric figure of merit value reached 0.132 under these optimal conditions. The results point to a potential pathway for a large-scale fabrication of low-cost oxide based thermoelectric with potential applicability at moderate to high temperatures.

  17. Les métamatériaux, des micro-ondes à l'optique : théorie et applications

    NASA Astrophysics Data System (ADS)

    Kante, B.

    2010-04-01

    Cet article constitue une contribution originale et importante à la compréhension à la fois théorique et expérimentale des métamatériaux en micro-ondes et en infrarouge. Nous avons réalisé et caractérisé sur silicium des nano-structures metallo-diélectriques, briques de base des métamatériaux infrarouge et optique. Des caractérisations optiques exhaustives ont été réalisées pour la première fois sur ces structures en amplitude et en phase par interférométrie. Des topologies plus simples de métamatériaux d’un point de vue technologique et des performances optiques ont été introduites, et leur potentiel démontré dans la réalisation de fonctions aussi complexes que la réfraction négative, le couplage de mode plasmoniques, les nano senseurs pour la biologie et l’invisibilité électromagnétique en infrarouge. Les transformations d’espace, et le nouveau paradigme qu’elles offrent à l’optique, rendant possible une ingénierie de l’espace pour les photons ainsi que leur implémentation par métamatériaux ont été présentés par la première démonstration expérimentale d’une cape d’invisibilité non magnétique.

  18. Hyperpolarized (129) Xe imaging of the rat lung using spiral IDEAL.

    PubMed

    Doganay, Ozkan; Wade, Trevor; Hegarty, Elaine; McKenzie, Charles; Schulte, Rolf F; Santyr, Giles E

    2016-08-01

    To implement and optimize a single-shot spiral encoding strategy for rapid 2D IDEAL projection imaging of hyperpolarized (Hp) (129) Xe in the gas phase, and in the pulmonary tissue (PT) and red blood cells (RBCs) compartments of the rat lung, respectively. A theoretical and experimental point spread function analysis was used to optimize the spiral k-space read-out time in a phantom. Hp (129) Xe IDEAL images from five healthy rats were used to: (i) optimize flip angles by a Bloch equation analysis using measured kinetics of gas exchange and (ii) investigate the feasibility of the approach to characterize the exchange of Hp (129) Xe. A read-out time equal to approximately 1.8 × T2* was found to provide the best trade-off between spatial resolution and signal-to-noise ratio (SNR). Spiral IDEAL approaches that use the entire dissolved phase magnetization should give an SNR improvement of a factor of approximately three compared with Cartesian approaches with similar spatial resolution. The IDEAL strategy allowed imaging of gas, PT, and RBC compartments with sufficient SNR and temporal resolution to permit regional gas exchange measurements in healthy rats. Single-shot spiral IDEAL imaging of gas, PT and RBC compartments and gas exchange is feasible in rat lung using Hp (129) Xe. Magn Reson Med 76:566-576, 2016. © 2015 Wiley Periodicals, Inc. © 2015 Wiley Periodicals, Inc.

  19. Thermoelectric properties of in-situ plasma spray synthesized sub-stoichiometry TiO2−x

    PubMed Central

    Lee, Hwasoo; Han, Su Jung; Chidambaram Seshadri, Ramachandran; Sampath, Sanjay

    2016-01-01

    The thermoelectric properties of sub-stoichiometric TiO2−x deposits produced by cascaded-plasma spray process are investigated from room-temperature to 750 K. Sub-stoichiometric TiO2−x deposits are formed through in-situ reaction of the TiO1.9 within the high temperature plasma flame and manipulated through introduction of varying amounts of hydrogen in the plasma. Although the TiO2−x particles experience reduction within plasma, it can also re-oxidize through interaction with the surrounding ambient atmosphere, resulting in a complex interplay between process conditions and stoichiometry. The deposits predominantly contain rutile phase with presence of Magneli phases especially under significantly reducing plasma conditions. The resultant deposits show sensitivity to thermoelectric properties and under certain optimal conditions repeatedly show Seebeck coefficients reaching values of −230 μV K−1 at temperatures of 750 K while providing an electrical conductivity of 5.48 × 103 S m−1, relatively low thermal conductivity in the range of 1.5 to 2 W m−1 K−1 resulting in power factor of 2.9 μW cm−1 K−2. The resultant maximum thermoelectric figure of merit value reached 0.132 under these optimal conditions. The results point to a potential pathway for a large-scale fabrication of low-cost oxide based thermoelectric with potential applicability at moderate to high temperatures. PMID:27811954

  20. Adsorption mechanism of ester phosphate on baryum titanate in organic medium. Preliminary results on the structure of the adsorbed layer

    NASA Astrophysics Data System (ADS)

    Le Bars, N.; Tinet, D.; Faugère, A. M.; van Damme, H.; Levitz, P.

    1991-05-01

    The purpose of this work is to evidence the adsorption mechanism and the structure of commercial phosphate ester surfactant stabilized BaTiO3 in organic suspension, and to relate these characteristics to rheological behaviour. Binders and plasticizers are omitted to reduce the number of system components. Firstly adsorption isotherm were determined by inductively coupled argon plasma technique and interpretated based on transmission electron microscopy and ^{31}P nuclear magnetic resonance studies. Preliminary rheological measurements were then performed and related to suspension structure. Structure of the adsorption layer is critically discussed. L'objectif de cette étude est la compréhension du mécanisme d'adsorption d'agents dispersants phosphatés dans des suspensions organiques de BaTiO3, ainsi que la caractérisation de la structure, et du comportement rhéologique de ces suspensions. Liants et plastifiants ne sont pas utilisés, afin de réduire le nombre de composants dans le système. Dans un premier temps, l'isotherme d'adsorption est établie par dosage en émission plasma, puis interprétée sur la base de résultats de Microscopie Eloctronique à Transmission, et de spectroscopie par Résonance Magnétique Nucléaire du ^{31}P. Des mesures rhéologiques préliminaires sont effectuées pour caractériser la structure des suspensions.