Overview of NASA Magnet and Linear Alternator Research Efforts
NASA Technical Reports Server (NTRS)
Geng, Steven M.; Schwarze, Gene E.; Nieda, Janis M.
2005-01-01
The Department of Energy, Lockheed Martin, Stirling Technology Company, and NASA Glenn Research Center are developing a high-efficiency, 110 watt Stirling Radioisotope Generator (SRG110) for NASA Space Science missions. NASA Glenn is conducting in-house research on rare earth permanent magnets and on linear alternators to assist in developing a free-piston Stirling convertor for the SRG110 and for developing advanced technology. The permanent magnet research efforts include magnet characterization, short-term magnet aging tests, and long-term magnet aging tests. Linear alternator research efforts have begun just recently at GRC with the characterization of a moving iron type linear alternator using GRC's alternator test rig. This paper reports on the progress and future plans of GRC's magnet and linear alternator research efforts.
Overview of NASA Magnet and Linear Alternator Research Efforts
NASA Astrophysics Data System (ADS)
Geng, Steven M.; Niedra, Janis M.; Schwarze, Gene E.
2005-02-01
The Department of Energy, Lockheed Martin, Stirling Technology Company, and NASA Glenn Research Center are developing a high-efficiency, 110 watt Stirling Radioisotope Generator (SRG110) for NASA Space Science missions. NASA Glenn is conducting in-house research on rare earth permanent magnets and on linear alternators to assist in developing a free-piston Stirling convertor for the SRG110 and for developing advanced technology. The permanent magnet research efforts include magnet characterization, short-term magnet aging tests, and long-term magnet aging tests. Linear alternator research efforts have begun just recently at GRC with the characterization of a moving iron type linear alternator using GRC's alternator test rig. This paper reports on the progress and future plans of GRC's magnet and linear alternator research efforts.
NASA Astrophysics Data System (ADS)
Rajkumar, K. V.; Vaidyanathan, S.; Kumar, Anish; Jayakumar, T.; Raj, Baldev; Ray, K. K.
2007-05-01
The best combinations of mechanical properties (yield stress and fracture toughness) of M250 maraging steel is obtained through short-term thermal aging (3-10 h) at 755 K. This is attributed to the microstructure containing precipitation of intermetallic phases in austenite-free low-carbon martensite matrix. Over-aged microstructure, containing reverted austenite degrades the mechanical properties drastically. Hence, it necessitates identification of a suitable non-destructive evaluation (NDE) technique for detecting any reverted austenite unambiguously during aging. The influence of aging on microstructure, room temperature hardness and non-destructive magnetic parameters such as coercivity ( Hc), saturation magnetization ( Ms) and magnetic Barkhausen emission (MBE) RMS peak voltage is studied in order to derive correlations between these parameters in aged M250 maraging steel. Hardness was found to increase with precipitation of intermetallics during initial aging and decrease at longer durations due to austenite reversion. Among the different magnetic parameters studied, MBE RMS peak voltage was found to be very sensitive to austenite reversion (non-magnetic phase) as they decreased drastically up on initiation of austenite reversion. Hence, this parameter can be effectively utilized to detect and quantify the reverted austenite in maraging steel specimen. The present study clearly indicates that the combination of MBE RMS peak voltage and hardness can be used for unambiguous characterization of microstructural features of technological and practical importance (3-10 h of aging duration at 755 K) in M250 grade maraging steel.
Influence of coating on nanocrystalline magnetic properties during high temperature thermal ageing
NASA Astrophysics Data System (ADS)
Lekdim, Atef; Morel, Laurent; Raulet, Marie-Ange
2017-05-01
Since their birth or mergence the late 1980s, the nanocrystalline ultrasoft magnetic materials are taking a great importance in power electronic systems conception. One of the main advantages that make them more attractive nowadays is their ability to be packaged since the reduction of the magnetostrictive constant to almost zero. In aircraft applications, due to the high component compactness and to their location (for example near the jet engine), the operating temperature increases and may reach easily 200 °C and more. Consequently, the magnetic thermal ageing may occur but is, unfortunately, weakly studied. This paper focuses on the influence of the coating (packaging type) on the magnetic nanocrystalline performances during a thermal ageing. This study is based on monitoring the magnetic characteristics of two types of nanocrystalline cores (naked and coated) during a thermal activated ageing (100, 150 and 200 °C). Based on a dedicated monitoring protocol, a large magnetic characterization has been done and analyzed. Elsewhere, X-Ray Diffraction and magnetostriction measurements were carried out to support the study of the anisotropy energies evolution with ageing. This latter is discussed in this paper to explain and give hypothesis about the ageing phenomena.
Magnetic Properties of a Fluvial Chronosequence From the Eastern Wind River Range, Wyoming
NASA Astrophysics Data System (ADS)
Quinton, E. E.; Dahms, D. E.; Geiss, C. E.
2010-12-01
In order to constrain the rate of magnetic enhancement in glacial fluvial sediments, we sampled modern soils from eight fluvial terraces in the East Wind River Range in Wyoming. Soil profiles up to 1.2 meters deep were described in the field and sampled in five cm intervals from a series of hand-dug pits or natural river-bank exposure. The age of the studied profiles are estimated to range from >600 ka to modern. They include Sacagawea Ridge, Bull Lake and Pinedale-age fluvial terraces as well as one Holocene profile. To characterize changes in magnetic properties we measured low-field magnetic susceptibility, anhysteretic remanent magnetization, isothermal remanent magnetization and S-ratios for all, and hysteresis loops for a selected sub-set of samples. Our measurements show no clear trend in magnetic enhancement with estimated soil age. The observed lack of magnetic enhancement in the older soils may be due to long-term deflation, which continuously strips off the magnetically enhanced topsoil. It is also possible that the main pedogenic processes, such as the development of well-expressed calcic horizons destroy or mask the effects of long-term magnetic enhancement.
A rock-magnetic record from Lake Baikal, Siberia: Evidence for Late Quaternary climate change
Peck, J.A.; King, J.W.; Colman, Steven M.; Kravchinsky, V.A.
1994-01-01
Rock-magnetic measurements of sediment cores from the Academician Ridge region of Lake Baikal, Siberia show variations related to Late Quaternary climate change. Based upon the well-dated last glacial-interglacial transition, variations in magnetic concentration and mineralogy are related to glacial-interglacial cycles using a conceptual model. Interglacial intervals are characterized by low magnetic concentrations and a composition that is dominated by low coercivity minerals. Glacial intervals are characterized by high magnetic concentrations and increased amounts of high coercivity minerals. The variation in magnetic concentration is consistent with dilution by diatom opal during the more productive interglacial periods. We also infer an increased contribution of eolian sediment during the colder, windier, and more arid glacial conditions when extensive loess deposits were formed throughout Europe and Asia. Eolian transport is inferred to deliver increased amounts of high coercivity minerals as staining on eolian grains during the glacial intervals. Variations in magnetic concentration and mineralogy of Lake Baikal sediment correlate to the SPECMAP marine oxygen-isotope record. The high degree of correlation between Baikal magnetic concentration/mineralogy and the SPECMAP oxygen-isotope record indicates that Lake Baikal sediment preserves a history of climate change in central Asia for the last 250 ka. This correlation provides a method of estimating the age of sediment beyond the range of the radiocarbon method. Future work must include providing better age control and additional climate proxy data, thereby strengthening the correlation of continental and marine climate records. ?? 1994.
Magnetic properties evolution of a high permeability nanocrystalline FeCuNbSiB during thermal ageing
NASA Astrophysics Data System (ADS)
Lekdim, Atef; Morel, Laurent; Raulet, Marie-Ange
2017-07-01
It is found to be one of the major issues while designing an aircraft, mass and volume have to be reduced in order to achieve energy efficiency. This leads to a high compactness of the electrical components which enables them to withstand at high temperatures. The magnetic components which are responsible for the electrical energy conversion, therefore exposed to high temperatures in working conditions. Their thermal ageing becomes a serious problem and deserves a particular attention. The FeCuNbSiB nanocrystalline materials have been selected for this ageing study because they are used in power electronic systems very frequently. The objective of the study is based on monitoring the magnetic characteristics under the condition of several continuous thermal ageing (100, 150, 200 and 240 °C). An important, experimental work of magnetic characterization is being done through a specific monitoring protocol and X-ray diffraction (XRD) along with magnetostriction measurements was carried out to support the study of the evolution of the anisotropy energies with aging. The latter is discussed in this paper to explain and give the hypothesis about the aging phenomena. Contribution to the topical issue "Electrical Engineering Symposium (SGE 2016)", edited by Adel Razek
Crystallographic, hyperfine and magnetic characterization of a maraging-400 alloy
NASA Astrophysics Data System (ADS)
Alves, T. J. B.; Nunes, G. C. S.; Sarvezuk, P. W. C.; Ivashita, F. F.; de Andrade, A. M. H.; Viegas, A.; Paesano, A.
2017-11-01
Maraging400-like alloys were made by arc-melting iron with the alloy elements (i.e., Ni, Co, Ti and Mo), followed by a high temperature heat-treatment for solubilization. The solubilized alloys were further heat-treated (480 °C and 580 °C, by 3 h), for aging. The samples were finely characterized by X-ray diffraction (Rietveld refinement), Mössbauer spectroscopy and magnetization techniques. The results revealed that the as-solubilized sample is martensitic and ferromagnetic. Its residual induction and coercive field increase monotonically with the maximum applied field of a magnetization minor loop and both curves presented very similar shapes. The area of the minor loops varies parabolically with this maximum applied field. The aging induced an atomic rearrangement in the martensite phase, involving change in the composition and lattice parameters, reversion of austenite and the formation of the Fe 3 Mo 2 intermetallic compound. Comparisons are presented between the results obtained by us for these alloys and those obtained for Maraging-350 steel samples.
Magnetic ageing study of high and medium permeability nanocrystalline FeSiCuNbB alloys
NASA Astrophysics Data System (ADS)
Lekdim, Atef; Morel, Laurent; Raulet, Marie-Ange
2017-04-01
increasing the energy efficiency is one of the most important issues in modern power electronic systems. In aircraft applications, the energy efficiency must be associated with a maximum reduction of mass and volume, so a high components compactness. A consequence from this compactness is the increase of operating temperature. Thus, the magnetic materials used in these applications, have to work at high temperature. It raises the question of the thermal ageing problem. The reliability of these components operating at this condition becomes a real problem which deserves serious interest. Our work takes part in this context by studying the magnetic material thermal ageing. The nanocrystalline materials are getting more and more used in power electronic applications. Main advantages of nanocrystalline materials compared to ferrite are: high saturation flux density of almost 1.25 T and low dynamic losses for low and medium frequencies. The nanocrystalline Fe73.5Cu1Nb3Si15.5B7 alloys have been chosen in our aging study. This study is based on monitoring the magnetic characteristics for several continuous thermal ageing (100, 150, 200 and 240 °C). An important experimental work of magnetic characterization is being done following a specific monitoring protocol. Elsewhere, X-Ray Diffraction and magnetostriction measurements were carried out to support the study of the anisotropy energies evolution with ageing. This latter is discussed in this paper to explain and give hypothesis about the ageing phenomena.
Pascual-Leone, Alvaro; Freitas, Catarina; Oberman, Lindsay; Horvath, Jared C.; Halko, Mark; Eldaief, Mark; Bashir, Shahid; Vernet, Marine; Shafi, Mouhshin; Westover, Brandon; Vahabzadeh-Hagh, Andrew M.; Rotenberg, Alexander
2012-01-01
Brain plasticity can be conceptualized as nature’s invention to overcome limitations of the genome and adapt to a rapidly changing environment. As such, plasticity is an intrinsic property of the brain across the life-span. However, mechanisms of plasticity may vary with age. The combination of transcranial magnetic stimulation (TMS) with electroencephalography (EEG) or functional magnetic resonance imaging (fMRI) enables clinicians and researchers to directly study local and network cortical plasticity, in humans in vivo, and characterize their changes across the age-span. Parallel, translational studies in animals can provide mechanistic insights. Here, we argue that, for each individual, the efficiency of neuronal plasticity declines throughout the age-span and may do so more or less prominently depending on variable ‘starting-points’ and different ‘slopes of change’ defined by genetic, biological, and environmental factors. Furthermore, aberrant, excessive, insufficient, or mistimed plasticity may represent the proximal pathogenic cause of neurodevelopmental and neurodegenerative disorders such as autism spectrum disorders or Alzheimer’s disease. PMID:21842407
Constraining the Date of the Martian Dynamo Shutdown by Means of Crater Magnetization Signatures
NASA Astrophysics Data System (ADS)
Vervelidou, Foteini; Lesur, Vincent; Grott, Matthias; Morschhauser, Achim; Lillis, Robert J.
2017-11-01
Mars is believed to have possessed a dynamo that ceased operating approximately 4 Ga ago, although the exact time is still under debate. The scope of this study is to constrain the possible timing of its cessation by studying the magnetization signatures of craters. The study uses the latest available model of the lithospheric magnetic field of Mars, which is based on Mars Global Surveyor data. We tackle the problem of nonuniqueness that characterizes the inversion of magnetic field data for the magnetization by inferring only the visible part of the magnetization, that is, the part of the magnetization that gives rise to the observed magnetic field. Further on, we demonstrate that a zero visible magnetization is a valid proxy for the entire magnetization being zero under the assumption of a magnetization distribution of induced geometry. This assumption holds for craters whose thermoremanent magnetization has not been significantly altered since its acquisition. Our results show that the dynamo shut off after the impacts that created the Acidalia and SE Elysium basins and before the crust within the Utopia basin cooled below its magnetic blocking temperature. Accounting for the age uncertainties in the dating of these craters, we estimate that the dynamo shut off at an N(300) crater retention age of 2.5-3.2 or an absolute model age of 4.12-4.14 Ga. Moreover, the Martian dynamo may have been weaker in its early stage, which if true implies that the driving mechanism of the Martian dynamo was not the same throughout its history.
Magnetic Signature of Glacial Flour in Sediments From Bear Lake, Utah/Idaho
NASA Astrophysics Data System (ADS)
Rosenbaum, J. G.; Dean, W. E.; Colman, S. M.; Reynolds, R. L.
2002-12-01
Variations in magnetic properties within an interval of Bear Lake sediments correlative with oxygen isotope stage 2 (OIS 2) and OIS 3 provide a record of glacial flour production for the Uinta Mountains. Like sediments of the same age from Upper Klamath Lake (OR), these Bear Lake sediments have high magnetic susceptibilities (MS) relative to non-glacial-age sediments and contain well-defined millennial-scale variations in magnetic properties. In contrast to glacial flour derived from volcanic rocks surrounding Upper Klamath Lake, glacial flour derived from the Uinta Mountains and deposited in Bear Lake by the Bear River has low magnetite content but high hematite content. The relatively low MS values of younger and older non-glacial-age sediments are due entirely to dilution by non-magnetic endogenic carbonate and to the effects of sulfidic alteration of detrital Fe-oxides. Analysis of samples from streams entering Bear Lake and from along the course of the Bear River demonstrates that, in comparison to other areas of the catchment, sediment derived from the Uinta Mountains is rich in hematite (high HIRM) and aluminum, and poor in magnetite (low MS) and titanium. Within the glacial-age lake sediments, there are strong positive correlations among HIRM, Al/Ti, and fine sediment grain size. MS varies inversely with theses three variables. These relations indicate that the observed millennial-scale variations in magnetic and chemical properties arise from varying proportions of two detrital components: (1) very fine-grained glacial flour derived from Proterozoic metasedimentary rocks in the Uinta Mountains and characterized by high HIRM and low MS, and (2) somewhat coarser material, characterized by higher MS and lower HIRM, derived from widespread sedimentary rocks along the course of the Bear River and around Bear Lake. Measurement of glacial flour incorporated in lake sediments can provide a continuous history of alpine glaciation, because the rate of accumulation of glacial flour probably varies closely with the areal extent of glaciation. In the absence of post-depositional alteration of magnetic minerals, magnetic measurements can provide a highly sensitive tool for assessing variations in glacial flour content if glacial and non-glacial materials have contrasting magnetic properties. For Bear Lake, the required contrast is produced by differences in bedrock underlying glaciated and unglaciated areas.
Makeup and uses of a basic magnet laboratory for characterizing high-temperature permanent magnets
NASA Technical Reports Server (NTRS)
Niedra, Janis M.; Schwarze, Gene E.
1991-01-01
A set of instrumentation for making basic magnetic measurements was assembled in order to characterize high intrinsic coercivity, rare earth permanent magnets with respect to short term demagnetization resistance and long term aging at temperatures up to 300 C. The major specialized components of this set consist of a 13 T peak field, capacitor discharge pulse magnetizer; a 10 in. pole size, variable gap electromagnet; a temperature controlled oven equipped with iron cobalt pole piece extensions and a removable paddle that carries the magnetization and field sensing coils; associated electronic integrators; and sensor standards for field intensity H and magnetic moment M calibration. A 1 cm cubic magnet sample, carried by the paddle, fits snugly between the pole piece extensions within the electrically heated aluminum oven, where fields up to 3.2 T can be applied by the electromagnet at temperatures up to 300 C. A sample set of demagnetization data for the high energy Sm2Co17 type of magnet is given for temperatures up to 300 C. These data are reduced to the temperature dependence of the M-H knee field and of the field for a given magnetic induction swing, and they are interpreted to show the limits of safe operation.
NASA Astrophysics Data System (ADS)
Saltus, R. W.; Oakey, G.; Miller, E. L.; Jackson, R.
2012-12-01
The magnetic anomalies of the high arctic are dominated by a large domain (1000 x 1700 km; the High Arctic Magnetic High, HAMH) consisting of numerous high-amplitude magnetic high ridges with a complex set of orientations and by other smaller, but still fundamentally highly magnetic, domains. The magnetic potential anomaly field (also known as pseudogravity) of the HAMH shows a single large intensity high and underscores the crustal-scale thickness of this geophysical feature (which also forms a prominent anomaly on satellite magnetic maps). The seafloor morphology of this region includes the complex linear trends of the Alpha and Mendeleev ridges, but the magnetic expression of this domain extends beyond the complex bathymetry to include areas where Canada Basin sediments have covered the complex basement topography. The calculated magnetic effect of the bathymetric ridges matches some of the observed magnetic anomalies, but not others. We have analyzed and modeled the distinctive HAMH and other smaller magnetic high domains to generate estimates of their volume and to characterize the directionality of their component features. Complimentary processing and modeling of high arctic gravity anomalies allows characterization of the density component of these geophysical features. Spatially, the HAMH encompasses the Alpha and Mendeleev "ridges," that are considered to represent a major mafic igneous province. The term "Alpha-Mendeleev Large Igneous Province" is given to a domain mapped by tracing magnetic anomalies in a recent map published by AAPG (Grantz and others, 2009). On this map the province is described as "alkali basalt with ages between 120 and 90 Ma". New seismic and bathymetric data, collected as part of on-going research efforts for definition of extended continental shelf, are revealing new details about the Alpha ridge. One interesting development is the possible identification of a supervolcano that may represent a major locus of igneous activity. In the broader Arctic region, the term High Arctic Large Igneous Province (HALIP) refers to (now) scattered parts of a major plume-type basaltic eruption, many of which also show as magnetic highs on the current data compilation. Rocks that contribute to this province have been mapped in Arctic Canada, Greenland, Svalbard, Franz Josef Land and the DeLong Islands. Most HALIP volcanic rocks do not have reliable reported radiometric ages but seem to indicate two pulses of magmatism of around 130-120 Ma and 90-80 Ma. There are many fundamental open questions regarding the evolution of the Arctic, particularly for the opening and development of the Amerasian side. The mafic igneous rocks and their roots that make up large igneous provinces are a good target for regional magnetic interpretation. Our goal is to use a data-driven approach to characterize the geometries and volumes these features as the expression of major mafic (basaltic) elements to aid in tectonic reconstruction and understanding.
NASA Astrophysics Data System (ADS)
Satolli, S.; Muttoni, G.; Di Cencio, A.; Lanci, L.
2017-12-01
The early Toarcian is globally characterized by a concomitance of extensional tectonics, volcanism, greenhouse conditions, marine transgression, mass extinction and increase in the total organic carbon, generally resulting in an organic rich facies known as the Toarcian oceanic anoxic event (T-OAE). These events have been related to the eruption of the Karoo-Ferrar igneous province. We characterize the time interval encompassing the T-OAE in the Marne del Serrone section (Northern Apennines, Italy). This 62-m-thick section is characterized by micritic limestones, red-green marls and by 50-cm-thick black shale and massive slumps in its bottom part. The age of the section has been constrained trough magnetostratigraphy and ammonite biostratigraphy in the Spinatum to Variabilis biozones. Non-oriented samples were collected at 5-to-10-cm sampling space and analyzed in order to detect variations in the magnetic minerals content. Rock magnetic investigations comprise mass-normalized NRM and magnetic susceptibility (MS), isothermal remanent magnetization (IRM) at room temperature, and thermal demagnetization of a three-component IRM. The section is magnetic-wise characterized by an alternate predominance of two end-members: magnetite and hematite. Higher SIRM coupled with lower S-ratio documented in red levels and nodular grey-reddish marl indicates higher presence of hematite, suggesting a detrital input. Instead, the black shale is characterized by a comparably high amount of magnetite. Here, the absence of hematite suggests the lack of continental influx. The cyclicity of rock magnetic parameters S-ratio and MS record was studied as a proxy for changes in productivity due to fluctuations in hematite of detrital origin. The latter reflects the expression of orbital modulation on the lithological alternations found in the upper part of the section (Bifrons biozone). The analysis allowed quantifying the timing and duration of the environmental change triggered by the Karoo-Ferrar event, which in the Marne del Serrone section is mirrored by a rapid increase in the SIRM starting in the "Posidonia Beds" and reaches its acme few meters above the anoxic level. The decrease in the magnetization of saturation is gradual after the event and characterized by peaks in the magnetization intensity.
Ntorkou, Alexandra A; Tsili, Athina C; Giannakis, Dimitrios; Batistatou, Anna; Stavrou, Sotirios; Sofikitis, Nikolaos; Argyropoulou, Maria I
2016-03-31
Cellular angiofibroma represents a rare mesenchymal tumor typically involving the inguinoscrotal area in middle-aged men. Although the origin of this benign tumor is unknown, it is histologically classified as an angiomyxoid tumor. Cellular angiofibroma is characterized by a diversity of pathological and imaging features. An accurate preoperative diagnosis is challenging. Magnetic resonance imaging examination of the scrotum has been reported as a valuable adjunct modality in the investigation of scrotal pathology. The technique by providing both structural and functional information is useful in the differentiation between extratesticular and intratesticular diseases and in the preoperative characterization of the histologic nature of various scrotal lesions. There are few reports in the English literature addressing the magnetic resonance imaging findings of cellular angiofibroma of the scrotum and no reports on functional magnetic resonance imaging data. Here we present the first case of a cellular angiofibroma arising from the tunica vaginalis of the testis and we discuss the value of a multiparametric magnetic resonance protocol, including diffusion-weighted imaging, magnetization transfer imaging and dynamic contrast-enhanced magnetic resonance imaging in the preoperative diagnosis of this rare neoplasm. A 47-year Greek man presented with a painless left scrotal swelling, which had gradually enlarged during the last 6 months. Magnetic resonance imaging of his scrotum displayed a left paratesticular mass, in close proximity to the tunica vaginalis, with heterogeneous high signal intensity on T2-weighted images and no areas of restricted diffusion. The tumor was hypointense on magnetization transfer images, suggestive for the presence of macromolecules. On dynamic contrast-enhanced magnetic resonance imaging the mass showed intense heterogeneous enhancement with a type II curve. Magnetic resonance imaging findings were strongly suggestive of a benign paratesticular tumor, which was confirmed on pathology following lesion excision. Magnetic resonance imaging of the scrotum by combining conventional and functional magnetic resonance data provides useful diagnostic information in the preoperative characterization of scrotal masses. A possible diagnosis of a benign paratesticular tumor based on magnetic resonance imaging features may improve patient care and decrease the number of unnecessary radical surgical explorations.
Izgi, Cemil; Vassiliou, Vassilis; Baksi, A John; Prasad, Sanjay K
2016-11-01
Differential diagnosis of asymmetrical left ventricular hypertrophy may be challenging, particularly in patients with history of hypertension. A middle-aged man underwent an echocardiographic examination during workup for hypertension, which unexpectedly showed significant asymmetrical septal hypertrophy and raised suspicion for hypertrophic cardiomyopathy. Cardiovascular magnetic resonance confirmed the asymmetrical hypertrophy. No myocardial late gadolinium contrast enhancement was seen. However, precontrast T1 mapping revealed a low native myocardial T1 value. This was highly suggestive of Anderson-Fabry disease, which was subsequently proved with very low alpha galactosidase enzyme levels and mutation analysis. The case illustrates clinical usefulness of multimodality imaging and the novel tissue characterization techniques for assessment of left ventricular hypertrophy. © 2016, Wiley Periodicals, Inc.
Gravity, Rotation, Ages, and Magnetism of Solar-like Stars and Red Giants observed by Kepler and K2
NASA Astrophysics Data System (ADS)
Mathur, Savita
Scientific Objectives: Asteroseismology has proved to be a very powerful tool thanks to the high-precision data obtained by the space missions such as Kepler and CoRoT. Solar-like oscillations have been detected and reported for around 15,600 red giants and 540 main-sequence stars observed by the nominal Kepler mission. Hence, these stars have their surface gravities, masses, and radii obtained with seismology. However, according to the latest Kepler star properties catalog (Mathur et al., in prep.) more than 24,000 red giants, 127,000 FGK dwarfs, and 10,000 subgiants were targeted. K2 has been observing 90,000 red giants and dwarfs. Moreover, the continuous photometric data of 4 yrs (resp. 3 mo) collected by Kepler (resp. K2) contain the signature of other phenomena such as convection, rotation, and magnetism, which are very important to understand stellar evolution and can also be used to obtain precise fundamental stellar parameters even when pulsations are not detected. We propose to perform the largest homogeneous analysis to date of seismic oscillations, convection, and rotation/magnetic activity across the full range of stellar spectral types and evolutionary states present in the K2 and Kepler missions. We will use the longest publicly available time series to derive the most accurate surface gravities, rotation periods, evolutionary states, and magnetic activity levels to characterize rotation-age-magnetic activity relationships and oscillations-magnetism interaction. Relevance: The determination of the gravity, mass, radius, and age of planet host stars allow us to better characterize the planetary systems. By studying the stellar surface rotation periods, we can better understand the angular momentum transport involved during the stellar evolution and have more accurate rotation-age relationships. Finally, the study of the magnetic activity of a large number of stars will allow us to put the Sun in a broader context. This work will also have an impact on galactic evolution study. Methodology: We will analyse the data with the new version of the A2Z pipeline (Mathur et al. 2010) on the stars where no acoustic modes have been detected or completely characterized so far. In the case that still no modes are observed, we will study the convective background as it has been shown that the granulation timescale is proportional to the surface gravity of the star (Mathur et al. 2011). We will develop and automate the recent method developed by Kallinger et al. (2016) that proved it is possible to measure logg very precisely with the auto-correlation function for stars where the modes are slightly above the Nyquist frequency, i.e. subgiants for the long cadence data. We will analyze dwarfs and subgiants observed by Kepler and K2 to look for their rotation periods following Garcia et al. (2014). This method was shown to have the best combination of completeness and reliability according to hare and hounds benchmarks (Aigrain et al., 2015). We will calibrate gyrochronology relation with the best-characterized dwarfs as done by van Saders et al. (2016) and apply it to dwarfs when applicable to estimate their ages. For the stars where a reliable rotation period is determined we will compute a photometric magnetic proxy as defined in Mathur et al. (2014). In many cases we will have complementary spectroscopic observations (e.g. Gaia). Data: We will analyse the Kepler Q0-Q17 data calibrated with the KADACS software (Garcia et al. 2011; Mathur et al. in prep.) and the K2 C1 to C7 data processed by Vanderburg & Johnson (2014).
NASA Astrophysics Data System (ADS)
Grison, Hana; Petrovsky, Eduard; Stejskalova, Sarka; Kapicka, Ales
2015-05-01
Identification of Andosols is primarily based upon the content of their colloidal constituents—clay and metal-humus complexes—and on the determining of andic properties. This needs time and cost-consuming geochemical analyses. Our primary aim of this study is to describe the magnetic and geochemical properties of soils rich in iron oxides derived from strongly magnetic volcanic basement (in this case Andosols). Secondary aim is to explore links between magnetic and chemical parameters of andic soils with respect to genesis factors: parent material age, precipitation, and thickness of the soil profile. Six pedons of andic properties, developed on basaltic lavas, were analyzed down to parent rock by a set of magnetic and geochemical methods. Magnetic data of soil and rock samples reflect the type, concentration, and particle-size distribution of ferrimagnetic minerals. Geochemical data include soil reaction (pH in H2O), cation exchange capacity, organic carbon, and different forms of extractable iron and aluminum content. Our results suggest the following: (1) magnetic measurements of low-field mass-specific magnetic susceptibility can be a reliable indicator for estimating andic properties, and in combination with thermomagnetic curves may be suitable for discriminating between alu-andic and sil-andic subtypes. (2) In the studied Andosols, strong relationships were found between (a) magnetic grain-size parameters, precipitation, and exchangeable bases; (b) concentration of ferrimagnetic particles and degree of crystallization of free iron; and (c) parameters reflecting changes in magneto-mineralogy and soil genesis (parent material age + soil depth).
NASA Astrophysics Data System (ADS)
Arenas, Mónica P.; Silveira, Rosa M.; Pacheco, Clara J.; Bruno, Antonio C.; Araujo, Jefferson F. D. F.; Eckstein, Carlos B.; Nogueira, Laudemiro; de Almeida, Luiz H.; Rebello, João M. A.; Pereira, Gabriela R.
2018-06-01
Heat-resistant austenitic stainless steels have become the principal alloys for use in steam reformer tubes in the petrochemical industry due to its mechanical properties. These tubes are typically exposed to severe operational conditions leading to microstructural transformations such as the aging phenomenon. The combination of high temperatures and moderate stresses causes creep damages, being necessary to monitor its structural condition by non-destructive techniques. The tube external wall is also subjected to oxidizing atmospheres, favoring the formation of an external surface, composed by an oxide scale and a chromium depleted zone. This external surface is usually not taken into account in the tube evaluation, which can lead to erroneous estimations of the service life of these components. In order to observe the magnetic influence of this layer, two samples, exposed to different operational temperatures, were characterized by non-destructive eddy current testing (ECT), scanning DC-susceptometer and magnetic force microscopy (MFM). It was found that the external surface thickness influences directly in the magnetic response of the samples.
Complementary Electromagnetic Non-Destructive Evaluation
NASA Astrophysics Data System (ADS)
Tian, Gui Yun; Wilson, John; Morozov, Maxim
2011-06-01
The use of non-destructive evaluation (NDE) for defect detection and failure prediction in structures and specimens is widespread in energy industries, aimed at ageing power plants and pipelines, material degradation, fatigue and radiation damage, etc. At present there are no suitable electromagnetic NDE methods for the measurement and characterization of material degradation, in irradiated samples in particular, which is very important and timely for the nuclear power industry in the UK. This paper reports recent developments in the field of electromagnetic (EM) NDE at Newcastle University, including pulsed eddy current (PEC), pulsed magnetic flux leakage (PMFL), magnetic Barkhausen emission (MBE) and magneto-acoustic emission (MAE). As different EM methods have different strengths, an integrative EM framework is introduced. Case studies through the second round robin tests organized by the Universal Network for Magnetic Non-Destructive Evaluation (UNMNDE), representing eighteen leading research groups worldwide in the area of electromagnetic NDE, are reported. Twelve samples with different ageing times and rolling reduction ratios were tested using different magnetic methods among the UNMNDE members. Based on the studies, the complementary characteristics of electromagnetic techniques for NDE are discussed.
NASA Astrophysics Data System (ADS)
Folsom, C. P.; Bouvier, J.; Petit, P.; Lèbre, A.; Amard, L.; Palacios, A.; Morin, J.; Donati, J.-F.; Vidotto, A. A.
2018-03-01
There is a large change in surface rotation rates of sun-like stars on the pre-main sequence and early main sequence. Since these stars have dynamo-driven magnetic fields, this implies a strong evolution of their magnetic properties over this time period. The spin-down of these stars is controlled by interactions between stellar and magnetic fields, thus magnetic evolution in turn plays an important role in rotational evolution. We present here the second part of a study investigating the evolution of large-scale surface magnetic fields in this critical time period. We observed stars in open clusters and stellar associations with known ages between 120 and 650 Myr, and used spectropolarimetry and Zeeman Doppler Imaging to characterize their large-scale magnetic field strength and geometry. We report 15 stars with magnetic detections here. These stars have masses from 0.8 to 0.95 M⊙, rotation periods from 0.326 to 10.6 d, and we find large-scale magnetic field strengths from 8.5 to 195 G with a wide range of geometries. We find a clear trend towards decreasing magnetic field strength with age, and a power law decrease in magnetic field strength with Rossby number. There is some tentative evidence for saturation of the large-scale magnetic field strength at Rossby numbers below 0.1, although the saturation point is not yet well defined. Comparing to younger classical T Tauri stars, we support the hypothesis that differences in internal structure produce large differences in observed magnetic fields, however for weak-lined T Tauri stars this is less clear.
Activation of Schwann cells in vitro by magnetic nanocomposites via applied magnetic field.
Liu, Zhongyang; Huang, Liangliang; Liu, Liang; Luo, Beier; Liang, Miaomiao; Sun, Zhen; Zhu, Shu; Quan, Xin; Yang, Yafeng; Ma, Teng; Huang, Jinghui; Luo, Zhuojing
2015-01-01
Schwann cells (SCs) are attractive seed cells in neural tissue engineering, but their application is limited by attenuated biological activities and impaired functions with aging. Therefore, it is important to explore an approach to enhance the viability and biological properties of SCs. In the present study, a magnetic composite made of magnetically responsive magnetic nanoparticles (MNPs) and a biodegradable chitosan-glycerophosphate polymer were prepared and characterized. It was further explored whether such magnetic nanocomposites via applied magnetic fields would regulate SC biological activities. The magnetization of the magnetic nanocomposite was measured by a vibrating sample magnetometer. The compositional characterization of the magnetic nanocomposite was examined by Fourier-transform infrared and X-ray diffraction. The tolerance of SCs to the magnetic fields was tested by flow-cytometry assay. The proliferation of cells was examined by a 5-ethynyl-2-deoxyuridine-labeling assay, a PrestoBlue assay, and a Live/Dead assay. Messenger ribonucleic acid of BDNF, GDNF, NT-3, and VEGF in SCs was assayed by quantitative real-time polymerase chain reaction. The amount of BDNF, GDNF, NT-3, and VEGF secreted from SCs was determined by enzyme-linked immunosorbent assay. It was found that magnetic nanocomposites containing 10% MNPs showed a cross-section diameter of 32.33±1.81 µm, porosity of 80.41%±0.72%, and magnetization of 5.691 emu/g at 8 kOe. The 10% MNP magnetic nanocomposites were able to support cell adhesion and spreading and further promote proliferation of SCs under magnetic field exposure. Interestingly, a magnetic field applied through the 10% MNP magnetic scaffold significantly increased the gene expression and protein secretion of BDNF, GDNF, NT-3, and VEGF. This work is the first stage in our understanding of how to precisely regulate the viability and biological properties of SCs in tissue-engineering grafts, which combined with additional molecular factors may lead to the development of new nerve grafts.
Zimmermann, Joelle; Ritter, Petra; Shen, Kelly; Rothmeier, Simon; Schirner, Michael; McIntosh, Anthony R
2016-07-01
Functional interactions in the brain are constrained by the underlying anatomical architecture, and structural and functional networks share network features such as modularity. Accordingly, age-related changes of structural connectivity (SC) may be paralleled by changes in functional connectivity (FC). We provide a detailed qualitative and quantitative characterization of the SC-FC coupling in human aging as inferred from resting-state blood oxygen-level dependent functional magnetic resonance imaging and diffusion-weighted imaging in a sample of 47 adults with an age range of 18-82. We revealed that SC and FC decrease with age across most parts of the brain and there is a distinct age-dependency of regionwise SC-FC coupling and network-level SC-FC relations. A specific pattern of SC-FC coupling predicts age more reliably than does regionwise SC or FC alone (r = 0.73, 95% CI = [0.7093, 0.8522]). Hence, our data propose that regionwise SC-FC coupling can be used to characterize brain changes in aging. Hum Brain Mapp 37:2645-2661, 2016. © 2016 Wiley Periodicals, Inc. © 2016 Wiley Periodicals, Inc.
Neural responses to reward in childhood: relations to early behavioral inhibition and social anxiety
Lahat, Ayelet; Benson, Brenda E; Pine, Daniel S; Fox, Nathan A; Ernst, Monique
2018-01-01
Abstract Behavioral inhibition (BI) is an early temperamental profile characterized by negative reactivity to novelty, withdrawal from social situations, and increased risk for social anxiety. Previous research associated BI assessed in early childhood to striatal hypersensitivity in mid-to-late adolescence. The present study examined this association among 10 year-olds, characterized with BI at ages 24 and 36 months on measures of temperamental reactivity. Participants (n = 40) were studied at age 10 using a reward processing task during functional magnetic resonance imaging (fMRI). Child- and maternal-report of social anxiety symptoms was collected at ages 10 and 13. Findings indicate greater caudate activation and stronger striatal connectivity in high, compared to low, behaviorally inhibited children. Caudate activation related to social anxiety symptoms at both ages. These findings suggest that enhanced striatal responsivity reliably manifests among high behaviorally inhibited children as early as age 10. This may reflect hyper-sensitivity to reward or excessive motivation to avoid errors. PMID:27531387
Origin and Evolution of Magnetic Field in PMS Stars: Influence of Rotation and Structural Changes
DOE Office of Scientific and Technical Information (OSTI.GOV)
Emeriau-Viard, Constance; Brun, Allan Sacha, E-mail: constance.emeriau@cea.fr, E-mail: sacha.brun@cea.fr
During stellar evolution, especially in the pre-main-sequence phase, stellar structure and rotation evolve significantly, causing major changes in the dynamics and global flows of the star. We wish to assess the consequences of these changes on stellar dynamo, internal magnetic field topology, and activity level. To do so, we have performed a series of 3D HD and MHD simulations with the ASH code. We choose five different models characterized by the radius of their radiative zone following an evolutionary track computed by a 1D stellar evolution code. These models characterized stellar evolution from 1 to 50 Myr. By introducing amore » seed magnetic field in the fully convective model and spreading its evolved state through all four remaining cases, we observe systematic variations in the dynamical properties and magnetic field amplitude and topology of the models. The five MHD simulations develop a strong dynamo field that can reach an equipartition state between the kinetic and magnetic energies and even superequipartition levels in the faster-rotating cases. We find that the magnetic field amplitude increases as it evolves toward the zero-age main sequence. Moreover, the magnetic field topology becomes more complex, with a decreasing axisymmetric component and a nonaxisymmetric one becoming predominant. The dipolar components decrease as the rotation rate and the size of the radiative core increase. The magnetic fields possess a mixed poloidal-toroidal topology with no obvious dominant component. Moreover, the relaxation of the vestige dynamo magnetic field within the radiative core is found to satisfy MHD stability criteria. Hence, it does not experience a global reconfiguration but slowly relaxes by retaining its mixed stable poloidal-toroidal topology.« less
Paleomagnetism and petrophysics of the Jänisjärvi impact structure, Russian Karelia
NASA Astrophysics Data System (ADS)
Salminen, J.; Donadini, F.; Pesonen, L. J.; Masaitis, V. L.; Naumov, M. V.
Paleomagnetic, rock magnetic, and petrophysical results are presented for impactites and target rocks from the Lake Jänisjärvi impact structure, Russian Karelia. The impactites (tagamites, suevites, and lithic breccias) are characterized by increased porosity and magnetization, which is in agreement with observations performed at other impact structures. Thermomagnetic, hysteresis, and scanning electron microscope (SEM) analysis document the presence of primary multidomain titanomagnetite with additional secondary titanomaghemite and ilmenohematite. The characteristic impact-related remanent magnetization (ChRM) direction (D = 101.5°, I = 73.1°, α95 = 6.2°) yields a pole (Lat. = 45.0°N, Long. = 76.9°E, dp = 9.9°, dm = 11.0°). Additionally, the same component is observed as an overprint on some rocks located in the vicinity of the structure, which provides proofs of its primary origin.An attempt was made to determine the ancient geomagnetic field intensity. Seven reliable results were obtained, yielding an ancient intensity of 68.7 ± 7.6 μT (corresponding to VDM of 10.3 ± 1.1 × 1022 Am2). The intensity, however, appears to be biased toward high values mainly because of the concave shape of the Arai diagrams.The new paleomagnetic data and published isotopic ages for the structure are in disagreement. According to well-defined paleomagnetic data, two possible ages for magnetization of Jänisjärvi rocks exist: 1) Late Sveconorwegian age (900-850 Myr) or 2) Late Cambrian age (˜500 Myr). However, published isotopic ages are 718 ± 5 Myr (K-Ar) and 698 ± 22 Myr (39Ar-40Ar), but such isotopic dating methods are often ambiguous for the impactites.
Magnetic Characterization of Organic Materials
2016-12-12
measurements. Magnetic shielding of nearby optical components was achieved for reliable experimental results. Magnetic -field applied ultrafast broadband...AFRL-AFOSR-JP-TR-2017-0005 Magnetic Characterization of Organic Materials Dongho Kim YONSEI UNIVERSITY UNIVERSITY-INDUSTRY FOUNDATION Final Report 12...Final 3. DATES COVERED (From - To) 10 Sep 2015 to 09 Sep 2016 4. TITLE AND SUBTITLE Magnetic Characterization of Organic Materials 5a. CONTRACT
Formation of Mass Transport Deposits on the Submarine Bank of Portimão (Gulf of Cadiz, SW Iberia)
NASA Astrophysics Data System (ADS)
Silva, Pedro; Roque, Cristina; Drago, Teresa; Lopes, Ana; Alonso, Belen; Vázquéz, Juan; Casas, David; Lopéz, Nieves; Ercilla, Gemma; Neres, Marta
2017-04-01
The development of submarine mass transport deposits (MTDs) plays an important geo-hazards role along continental margins. Accordingly, their identification and characterization is crucial to understand their sources, dynamics, frequency and spatial distribution. In this work a piston core located at the slope (2876 m water depth) of the southern flank of Portimao Bank (Portugal, Gulf of Cadiz, SW Iberia) underwent detailed magnetic (fabric and rock magnetism) and sedimentological (grain-size, carbonates, organic matter) analyses complemented by AMS 14C dating. Such multidisciplinary study identified about one meter of sediments that is unconformable with the ages obtained above and below this layer. Its magnetic fabric, as determined by anisotropy of magnetic susceptibility, indicates sharply changes from oblate to neutral shape, decrease of the anisotropy and preferred orientation of the magnetic susceptibility ellipsoid. Such layer is also individualized by sedimentary parameters, especially in its upper part by a lighter colour and decrease of the mean grain size than the rest of the core. Based on these results it is possible to conclude that the sedimentary column analyzed here shows evidence of an on-going development of a slide, which is well individualized and characterized by magnetic fabric studies. The authors wish to acknowledge MONTERA (CTM2009-14157-C02) project for its major contribution without which this work wouldn't be possible. Publication supported by project FCT UID/GEO/50019/2013 - Instituto Dom Luiz. Keywords: Submarine mass transport deposits, magnetic fabrics, Portimão bank, Gulf of Cadiz.
Goji, Aya; Ito, Hiromichi; Mori, Kenji; Harada, Masafumi; Hisaoka, Sonoka; Toda, Yoshihiro; Mori, Tatsuo; Abe, Yoko; Miyazaki, Masahito; Kagami, Shoji
2017-01-01
Proton magnetic resonance spectroscopy (1H MRS) is a noninvasive neuroimaging method to quantify biochemical metabolites in vivo and it can serve as a powerful tool to monitor neurobiochemical profiles in the brain. Asperger's syndrome (AS) is a type of autism spectrum disorder, which is characterized by impaired social skills and restrictive, repetitive patterns of interest and activities, while intellectual levels and language skills are relatively preserved. Despite clinical aspects have been well-characterized, neurometabolic profiling in the brain of AS remains to be clear. The present study used proton magnetic resonance spectroscopy (1H MRS) to investigate whether pediatric AS is associated with measurable neurometabolic abnormalities that can contribute new information on the neurobiological underpinnings of the disorder. Study participants consisted of 34 children with AS (2-12 years old; mean age 5.2 (±2.0); 28 boys) and 19 typically developed children (2-11 years old; mean age 5.6 (±2.6); 12 boys) who served as the normal control group. The 1H MRS data were obtained from two regions of interest: the anterior cingulate cortex (ACC) and left cerebellum. In the ACC, levels of N-acetylaspartate (NAA), total creatine (tCr), total choline-containing compounds (tCho) and myo-Inositol (mI) were significantly decreased in children with AS compared to controls. On the other hand, no significant group differences in any of the metabolites were found in the left cerebellum. Neither age nor sex accounted for the metabolic findings in the regions. The finding of decreased levels of NAA, tCr, tCho, and mI in the ACC but not in left cerebellar voxels in the AS, suggests a lower ACC neuronal density in the present AS cohort compared to controls.
STELLAR EVIDENCE THAT THE SOLAR DYNAMO MAY BE IN TRANSITION
DOE Office of Scientific and Technical Information (OSTI.GOV)
Metcalfe, Travis S.; Egeland, Ricky; Van Saders, Jennifer
2016-07-20
Precise photometry from the Kepler space telescope allows not only the measurement of rotation in solar-type field stars, but also the determination of reliable masses and ages from asteroseismology. These critical data have recently provided the first opportunity to calibrate rotation–age relations for stars older than the Sun. The evolutionary picture that emerges is surprising: beyond middle-age the efficiency of magnetic braking is dramatically reduced, implying a fundamental change in angular momentum loss beyond a critical Rossby number (Ro ∼ 2). We compile published chromospheric activity measurements for the sample of Kepler asteroseismic targets that were used to establish themore » new rotation–age relations. We use these data along with a sample of well-characterized solar analogs from the Mount Wilson HK survey to develop a qualitative scenario connecting the evolution of chromospheric activity to a fundamental shift in the character of differential rotation. We conclude that the Sun may be in a transitional evolutionary phase, and that its magnetic cycle might represent a special case of stellar dynamo theory.« less
Neutron stars: Observational diversity and evolution
NASA Astrophysics Data System (ADS)
Safi-Harb, S.
2017-12-01
Ever since the discovery of the Crab and Vela pulsars in their respective Supernova Remnants, our understanding of how neutron stars manifest themselves observationally has been dramatically shaped by the surge of discoveries and dedicated studies across the electromagnetic spectrum, particularly in the high-energy band. The growing diversity of neutron stars includes the highly magnetized neutron stars (magnetars) and the Central Compact Objects shining in X-rays and mostly lacking pulsar wind nebulae. These two subclasses of high-energy objects, however, seem to be characterized by anomalously high or anomalously low surface magnetic fields (thus dubbed as ‘magnetars’ and ‘anti-magnetars’, respectively), and have pulsar characteristic ages that are often much offset from their associated SNRs’ ages. In addition, some neutron stars act ‘schizophrenic’ in that they occasionally display properties that seem common to more than one of the defined subclasses. I review the growing diversity of neutron stars from an observational perspective, then highlight recent and on-going theoretical and observational work attempting to address this diversity, particularly in light of their magnetic field evolution, energy loss mechanisms, and supernova progenitors’ studies.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Weis, Tanja; Engel, Dieter; Ehresmann, Arno
2008-12-15
A quantitative analysis of magnetic force microscopy (MFM) images taken in external in-plane magnetic fields is difficult because of the influence of the magnetic field on the magnetization state of the magnetic probe tip. We prepared calibration samples by ion bombardment induced magnetic patterning with a topographically flat magnetic pattern magnetically stable in a certain external magnetic field range for a quantitative characterization of the MFM probe tip magnetization in point-dipole approximation.
2016-06-01
TECHNICAL REPORT Algorithm for Automatic Detection, Localization and Characterization of Magnetic Dipole Targets Using the Laser Scalar...Automatic Detection, Localization and Characterization of Magnetic Dipole Targets Using the Laser Scalar Gradiometer Leon Vaizer, Jesse Angle, Neil...of Magnetic Dipole Targets Using LSG i June 2016 TABLE OF CONTENTS INTRODUCTION
NASA Astrophysics Data System (ADS)
Vazquez, G.; Ortega, B.; Rodriguez, A.
2007-05-01
The lake is located near the Pacific coast of Mexico, at the western end of the Trans Mexican Volcanic Belt. It is a deep lake (ca. 65 m) with steep sides and only a small bay (Agua Caliente) has shallower water (ca. 12 m). Four parallel cores between 4 and 9 m long were recovered in March 2002 from this shallower area. Sediments are characterized by alternated laminations (few millimeters to 2 cm) of sand, brown silt, green silt, reddish silt, ochre silt, and peat. The 14-C dated sequence spans the last ca. 2,600 yrs. Given this age, it is possible that each set of laminations represent annual sedimentation cycles. The record is a potential high- resolution archive of environmental and climatic variability for western Mexico for late Holocene. Magnetic measurements of susceptibility along the cores show a high variability in the concentration of magnetic mineralogy. Different magnetic and non-magnetic properties show two sets of facies in relation to its magnetic mineralogy; one group composed by sand, brown silt, green silt and peat has the magnetite and Ti-magnetite as the principal magnetic phase; the second group, composed by reddish and ochre silt, has a low Ti magnetite component and siderite, as the principal paramagnetic component. The effects of climatic variations such as the drought occurred in the archeological Classic period (100 - 900 dC), the Medieval Warm Period (950 - 1350 dC), the Little Ice Age (1400 - 1800 dC), and the droughts over the last 700 years, documented in sites along central Mexico, are recognized in the magnetic mineralogy of Santa Maria del Oro.
NASA Technical Reports Server (NTRS)
DeSilva, J .H. S. R.; Udinwe, V.; Sideris, P. J.; Smart, M. C.; Krause, F. C.; Hwang, C.; Smith, K. A.; Greenbaum, S. G.
2012-01-01
Solid electrolyte interphase (SEI) formation in lithium ion cells prepared with advanced electrolytes is investigated by solid state multinuclear (7Li, 19F, 31P) magnetic resonance (NMR) measurements of electrode materials harvested from cycled cells subjected to an accelerated aging protocol. The electrolyte composition is varied to include the addition of fluorinated carbonates and triphenyl phosphate (TPP, a flame retardant). In addition to species associated with LiPF6 decomposition, cathode NMR spectra are characterized by the presence of compounds originating from the TPP additive. Substantial amounts of LiF are observed in the anodes as well as compounds originating from the fluorinated carbonates.
NASA Astrophysics Data System (ADS)
Rao, G. V. S. Jayapala; Prasad, T. N. V. K. V.; Shameer, Syed; Rao, M. Purnachandra
2018-04-01
Neodymium iron boron (NdFeB) permanent magnets have high energy product with suitable magnetic and physical properties for an array of applications including power generation and motors. However, synthetic routes of NdFeB permanent magnets involve critical procedures with high energy and needs scientific skills. Herein, we report on soapnut extract mediated synthesis of nanoscale cobalt substituted NdFeB (Co-NdFeB) permanent magnetic powders (Nd: 15%, Fe: 77.5%, B: 7.5% and Co with molar ratios: 0.5, 1, 1.5 and 2). A 10 ml of 10% soapnut extract was added to 90 ml of respective chemical composition and heated to 60 °C for 30 min and aged for 24 h. The dried powder was sintered at 500 °C for 1 h. The characterization of the prepared nanoscale Co-NdFeB magnetic powders was done using the techniques such as Dynamic Light Scattering (DLS for size and zeta potential measurements), X-ray diffraction (XRD) for structural determination, Scanning electron microscopy (SEM) with energy dispersion spectroscopy (EDS) for surface morphological and elemental analysis, Fourier transform infrared spectroscopy (FT-IR) for the identification of functional groups associated and hysteresis loop studies to quantify the magnetization. The results revealed that particles were in irregular and tubular shaped and highly stable (Zeta potential: -44.4 mV) with measured size <100 nm. XRD micrographs revealed a tetragonal crystal structure and FTIR showed predominant N-H and O-H stretching indicates the involvement of these functional groups in the reduction and stabilization process of Co-NdFeB magnetic powders. Hysteresis studies signify the effect of an increase in Co concentration.
NASA Technical Reports Server (NTRS)
Urrutia-Fucugauchi, J.; Marin, Luis; Sharpton, Virgil L.
1994-01-01
We report paleomagnetic results for core samples of the breccia and andesitic rocks recovered from the Yucatan-6 Petrolcos Mexicanos exploratory well within the Chicxulub structure (about 60 km SSW from its center), northern Yucatan, Mexico. A previous study has shown that the rocks studied contain high iridium levels and shocked breccia clasts and an Ar/Ar date of 65.2 +/- 0.4 Ma. Andesitic rocks are characterized by stable single-component magnetizations with a mean inclination of -42.6 deg +/- 2.4 deg. Breccias present a complex paleomagnetic record characterized by multivectorial magnetizations with widely different initial NRM inclinations. However, after alternating field demagnetization, well defined characteristic components with upward inclinations are defined. IRM acquisition experiments, comparison of IRM and NRM coercivity spectra and the single component magnetization of the andesitic rocks indicate the occurrence of iron-rich titanomagnetites of single or pseudo-single domain states as the dominant magnetic carriers. Mean inclinations from the andesitic rocks and most of the breccia samples give a mean inclination of about -40 deg to -45 deg, indicating a reverse polarity for the characteristic magnetization that is consistent with geomagnetic chron 29R, which spans the Cretaceous/Tertiary (K/T) boundary. The inclination is also consistent with the expected value (and corresponding paleolatitude) for the site estimated from the reference polar wander curve for North America. We suggest that the characteristic magnetizations for the andesitic and breccia rocks are the result of shock heating at the time of formation of the impact structure and that the age, polarity and pateolatitude are consistent with a time at the K/T boundary.
Rapid Characterization of Magnetic Moment of Cells for Magnetic Separation
Ooi, Chinchun; Earhart, Christopher M.; Wilson, Robert J.; Wang, Shan X.
2014-01-01
NCI-H1650 lung cancer cell lines labeled with magnetic nanoparticles via the Epithelial Cell Adhesion Molecule (EpCAM) antigen were previously shown to be captured at high efficiencies by a microfabricated magnetic sifter. If fine control and optimization of the magnetic separation process is to be achieved, it is vital to be able to characterize the labeled cells’ magnetic moment rapidly. We have thus adapted a rapid prototyping method to obtain the saturation magnetic moment of these cells. This method utilizes a cross-correlation algorithm to analyze the cells’ motion in a simple fluidic channel to obtain their magnetophoretic velocity, and is effective even when the magnetic moments of cells are small. This rapid characterization is proven useful in optimizing our microfabricated magnetic sifter procedures for magnetic cell capture. PMID:24771946
Magnetic and Geochemical Properties of Andic Soils from the Massif Central, France
NASA Astrophysics Data System (ADS)
Grison, H.; Petrovsky, E.; Dlouha, S.; Kapicka, A.
2014-12-01
Ferrimagnetic iron oxides are the key magnetic minerals responsible for enhancement of the magnetic susceptibility in soils. Soils with andic properties contain high amount of Fe-oxides, but only few attempts were made to characterize these soils using magnetic methods. Magnetic susceptibility is in particular suitable for its sensitivity and fast measurement; the presence of Fe-oxides can be easily identified directly in the field. The aim of our study is to describe main magnetic and geochemical properties of soils rich in Fe oxides derived from strongly magnetic volcanic basement. The studied sites are located at the basalt parent rock formed during Pleistocene, Pliocene and Miocene. Investigated soils are exposed to the mountainous climate with the perudic soil moisture regime and cryic temperature soil regime. Seven basalt soil profiles with typical andic properties were analyzed down to parent rock by a set of magnetic and geochemical methods. The magnetic susceptibility was measured in situ and in laboratory using the Bartington MS2D and AGICO MFK1. Its temperature dependence was measured in order to assess phase transformations of magnetic minerals using the KLY4. Magnetic data were completed by the hysteresis, IRM and DCD measurements using ADE EV9 VSM. Geochemical data include soil reaction (pH), organic carbon, cations exchange capacity, and extractable iron and aluminium in the soil extracted by a dithionite-citrate, acid-ammonium oxalate and a pyrophosphate solution. Scanning electron microscopy was done for top/sub-soil and rock samples. Geochemical soil properties reflecting iron oxide stability correlate well with mass-specific magnetic susceptibility. Well pronounced relationship was observed between magnetic grain size, precipitation and soil pH, second group is reflecting concentration of feri-magnetic particles and age of parent rock, and the third group reflects degree of weathering and the thermomagnetic indices expressing changes in magneto-mineralogy along the soil profiles. Influence of the weathering processes on all the measured parameters is discussed. Soil genesis is influenced by several factors, where the moisture is more important than the age of the parent material. Acknowledgement: This study was supported by Czech Science Foundation through grant No 13-10775S.
NASA Technical Reports Server (NTRS)
Eglinton, G.; Gowar, A. P.; Jull, A. J. T.; Pillinger, C. T.; Agrell, S. O.; Agrell, J. E.; Long, J. V. P.; Bowie, S. H. U.; Simpson, P. R.; Beckinsale, R. D.
1977-01-01
Samples of Luna 16 and 20 have been separated according to size, visual appearance, density, and magnetic susceptibility. Selected aliquots were examined in eight British laboratories. The studies included mineralogy and petrology, selenochronology, magnetic characteristics, Mossbauer spectroscopy, oxygen isotope ratio determinations, cosmic ray track and thermoluminescence investigations, and carbon chemistry measurements. Luna 16 and 20 are typically mare and highland soils, comparing well with their Apollo counterparts, Apollo 11 and 16, respectively. Both soils are very mature (high free iron, carbide, and methane and cosmogenic Ar), while Luna 16, but not Luna 20, is characterized by a high content of glassy materials. An aliquot of anorthosite fragments, handpicked from Luna 20, had a gas retention age of about 4.3 plus or minus 0.1 Gy.
Fernández-Cabello, Sara; Valls-Pedret, Cinta; Schurz, Matthias; Vidal-Piñeiro, Dídac; Sala-Llonch, Roser; Bargallo, Nuria; Ros, Emilio; Bartrés-Faz, David
2016-12-01
Cognitive reserve (CR) models posit that lifestyle factors such as education modulate the relationship between brain damage and cognition. However, the functional correlates of CR in healthy aging are still under investigation. White matter hyperintensities (WMHs) are a common age-associated finding that impacts cognition. In this study, we used functional magnetic resonance imaging to characterize the patterns of brain activation during a working memory task in older participants with high and low levels of education (as a proxy of CR) and high and low WMH volumes. Ninety older volunteers (aged 63-76 years) and 16 young adults (aged 21-27) completed the study. We found that older adults with higher education had better working memory performance than their less educated peers. Among the highly educated participants, those with WMH over-recruited areas engaged by young volunteers and showed activation in additional cortical and subcortical structures. However, those with low WMH differed little with respect to their younger counterparts. Our findings demonstrate that the functional mechanisms subtending the effects of education, as a proxy of CR, are modulated according to the WMH burden. Copyright © 2016 Elsevier Inc. All rights reserved.
Low cortical iron and high entorhinal cortex volume promote cognitive functioning in the oldest-old.
van Bergen, Jiri M G; Li, Xu; Quevenco, Frances C; Gietl, Anton F; Treyer, Valerie; Leh, Sandra E; Meyer, Rafael; Buck, Alfred; Kaufmann, Philipp A; Nitsch, Roger M; van Zijl, Peter C M; Hock, Christoph; Unschuld, Paul G
2018-04-01
The aging brain is characterized by an increased presence of neurodegenerative and vascular pathologies. However, there is substantial variation regarding the relationship between an individual's pathological burden and resulting cognitive impairment. To identify correlates of preserved cognitive functioning at highest age, the relationship between β-amyloid plaque load, presence of small vessel cerebrovascular disease (SVCD), iron-burden, and brain atrophy was investigated. Eighty cognitively unimpaired participants (44 oldest-old, aged 85-96 years; 36 younger-old, aged 55-80 years) were scanned by integrated positron emission tomography-magnetic resonance imaging for assessing beta regional amyloid plaque load (18F-flutemetamol), white matter hyperintensities as an indicator of SVCD (fluid-attenuated inversion recovery-magnetic resonance imaging), and iron load (quantitative susceptibility mapping). For the oldest-old group, lower cortical volume, increased β-amyloid plaque load, prevalence of SVCD, and lower cognitive performance in the normal range were found. However, compared to normal-old, cortical iron burden was lower in the oldest-old. Moreover, only in the oldest-old, entorhinal cortex volume positively correlated with β-amyloid plaque load. Our data thus indicate that the co-occurrence of aging-associated neuropathologies with reduced quantitative susceptibility mapping measures of cortical iron load constitutes a lower vulnerability to cognitive loss. Copyright © 2017 Elsevier Inc. All rights reserved.
NASA Astrophysics Data System (ADS)
Emmanuel, Nsifa Nkonguin; Rigobert, Tchameni; Anne, Nédélec; Roberto, Siqueira; André, Pouclet; Jérôme, Bascou
2013-11-01
Three late-Neoproterozoic nepheline syenite intrusions crop out close to the late-Pan-African SW Cameroon shear zone, namely the Mont des Eléphants, Eboundja and Rocher du Loup intrusions. They are characterized by magmatic to solid-state deformation structures and microstructures. Their magmas were mainly derived from partial melting of the subcontinental lithospheric mantle. Magmatic differentiation may have occurred through fractionation of clinopyroxene, amphibole, plagioclase and accessory minerals (apatite, sphene, magnetite and zircon). Bulk magnetic susceptibilities are variable in intensity depending of the magnetite content. Their magnetic anisotropies are unusally high, especially in the Rocher du Loup intrusion. The trajectories of magnetic foliations and lineations display an arcuate shape from an E-W direction in the easternmost Mont des Eléphants to a N-S direction in the Rocher du Loup intrusion. These features are consistent with a synkinematic emplacement in relation with the sinistral motion along the SW Cameroon shear zone, whose age is therefore dated by the age of the syenites, i.e. 590 Ma. Magma genesis and ascent was likely favored by a large gradient in lithospheric thickness along the western margin of the Congo craton.
[Evaluation of cardiac tumors by multidetector computed tomography and magnetic resonance imaging].
Mercado-Guzman, Marcela P; Meléndez-Ramírez, Gabriela; Castillo-Castellon, Francisco; Kimura-Hayama, Eric
Cardiac tumors, are a rare pathology (0.002-0.3%) in all age groups, however, they have a clinic importance, due the affected organ. They are classified in primary (benign or malignant) and secondary (metastasis) types. Among primary type, mixoma, is the most common benign tumor, and sarcoma represents most of the malignant injuries. Cardiac metastasis are more frequent than primary tumors. Clinic effects of cardiac tumors are unspecific and vary according their location, size and agresivity. The use of Multidetector Computed Tomography (MDCT) and Magnetic Resonance Imaging (MRI) assist on the location, sizing, anatomical relationships and the compromise of adyacents structures, besides, MRI is useful for tissue characterization of the tumor. Due to the previous reasons, studies based on noninvasive cardiovascular imaging, have an important role on the characterization of these lesions and the differential diagnosis among them. Copyright © 2016 Instituto Nacional de Cardiología Ignacio Chávez. Publicado por Masson Doyma México S.A. All rights reserved.
NASA Astrophysics Data System (ADS)
Ramudu, M.; Rajkumar, D. M.
2018-04-01
The effect of aging time on the magnetic properties of Sm2Co17 permanent magnets processed through a novel method of cold isostatic pressing was investigated. Sintered Sm2Co17 samples were subjected to different aging times in the range of 10-30 h and their respective microstructures were correlated with the magnetic properties obtained. The values of remanant magnetization (Br) were observed to be constant in samples aged from 10-20 h beyond which a gradual decrease in Br values was observed. The values of coercivity (Hc) displayed a sharp increase in samples aged from 10 to 20 h beyond which the coercivity values showed marginal improvement. Hence a good combination of magnetic properties could be achieved in samples aged for 20 h. A maximum energy product of 27 MGOe was achieved in the 20 h aged sample processed through a novel route.
The Effects of Magnetic Activity on Lithium-Inferred Ages of Stars
NASA Astrophysics Data System (ADS)
Juarez, Aaron J.; Cargile, Phillip A.; James, David J.; Stassun, Keivan G.
2014-08-01
In this project, we investigate the effects of magnetic activity on the Lithium Depletion Boundary (LDB) to recalibrate the measured ages for star clusters, using the open cluster Blanco 1 as a pilot study. We apply the LDB technique on low-mass Pre-Main-Sequence (PMS) stars to derive an accurate age for Blanco 1, and we consider the effect of magnetic activity on this inferred age. Although observations have shown that magnetic activity directly affects stellar radius and temperature, most PMS models do not include the effects of magnetic activity on stellar properties. Since the lithium abundance of a star depends on its radius and temperature, we expect that LDB ages are affected by magnetic activity. After empirically accounting for the effects of magnetic activity, we find the age of Blanco 1 to be ~100 Myr, which is ~30 Myr younger than the standard LDB age of ~130 Myr.
Park, Hyun Soon; Hirata, Kei; Yanagisawa, Keiichi; Ishida, Yoichi; Matsuda, Tsuyoshi; Shindo, Daisuke; Tonomura, Akira
2012-12-07
Nanostructured magnetic materials play an important role in increasing miniaturized devices. For the studies of their magnetic properties and behaviors, nanoscale imaging of magnetic field is indispensible. Here, using electron holography, the magnetization distribution of a TMR spin valve head of commercial design is investigated without and with a magnetic field applied. Characterized is the magnetic flux distribution in complex hetero-nanostructures by averaging the phase images and separating their component magnetic vectors and electric potentials. The magnetic flux densities of the NiFe (shield and 5 nm-free layers) and the CoPt (20 nm-bias layer) are estimated to be 1.0 T and 0.9 T, respectively. The changes in the magnetization distribution of the shield, bias, and free layers are visualized in situ for an applied field of 14 kOe. This study demonstrates the promise of electron holography for characterizing the magnetic properties of hetero-interfaces, nanostructures, and catalysts. Copyright © 2012 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.
NASA Astrophysics Data System (ADS)
Esa, Mohammad Faris Mohammad; Rahim, Faszly; Hassan, Ibrahim Haji; Hanifah, Sharina Abu
2015-09-01
Magnetic material such as magnetite are known as particles that respond to external magnetic field with their ferromagnetic properties as they are believed contribute to in responding to the geomagnetic field. These particles are used by terrestrial animals such as termites for navigation and orientation. Since our earth react as giant magnetic bar, the magnitude of this magnetic field present by intensity and direction (inclination and direction). The magnetic properties and presence of magnetite in termites Macrotermes gilvus, common mound-building termite were tested. M. gilvus termites was tested with a Vibrating Sample Magnetometer VSM to determine the magnetic properties of specimen. The crushed body sample was characterized with X-Ray Diffraction XRD to show the existent of magnetic material (magnetite) in the specimens. Results from VSM indicate that M. gilvus has diamagnetism properties. The characterization by XRD shows the existent of magnetic material in our specimen in low concentration.
Ageing and brain white matter structure in 3,513 UK Biobank participants
Cox, Simon R.; Ritchie, Stuart J.; Tucker-Drob, Elliot M.; Liewald, David C.; Hagenaars, Saskia P.; Davies, Gail; Wardlaw, Joanna M.; Gale, Catharine R.; Bastin, Mark E.; Deary, Ian J.
2016-01-01
Quantifying the microstructural properties of the human brain's connections is necessary for understanding normal ageing and disease. Here we examine brain white matter magnetic resonance imaging (MRI) data in 3,513 generally healthy people aged 44.64–77.12 years from the UK Biobank. Using conventional water diffusion measures and newer, rarely studied indices from neurite orientation dispersion and density imaging, we document large age associations with white matter microstructure. Mean diffusivity is the most age-sensitive measure, with negative age associations strongest in the thalamic radiation and association fibres. White matter microstructure across brain tracts becomes increasingly correlated in older age. This may reflect an age-related aggregation of systemic detrimental effects. We report several other novel results, including age associations with hemisphere and sex, and comparative volumetric MRI analyses. Results from this unusually large, single-scanner sample provide one of the most extensive characterizations of age associations with major white matter tracts in the human brain. PMID:27976682
Earhart, Christopher M.; Hughes, Casey E.; Gaster, Richard S.; Ooi, Chin Chun; Wilson, Robert J.; Zhou, Lisa Y.; Humke, Eric W.; Xu, Lingyun; Wong, Dawson J.; Willingham, Stephen B.; Schwartz, Erich J.; Weissman, Irving L.; Jeffrey, Stefanie S.; Neal, Joel W.; Rohatgi, Rajat; Wakelee, Heather A.; Wang, Shan X.
2014-01-01
Detection and characterization of circulating tumor cells (CTCs) may reveal insights into the diagnosis and treatment of malignant disease. Technologies for isolating CTCs developed thus far suffer from one or more limitations, such as low throughput, inability to release captured cells, and reliance on expensive instrumentation for enrichment or subsequent characterization. We report a continuing development of a magnetic separation device, the magnetic sifter, which is a miniature microfluidic chip with a dense array of magnetic pores. It offers high efficiency capture of tumor cells, labeled with magnetic nanoparticles, from whole blood with high throughput and efficient release of captured cells. For subsequent characterization of CTCs, an assay, using a protein chip with giant magnetoresistive nanosensors, has been implemented for mutational analysis of CTCs enriched with the magnetic sifter. The use of these magnetic technologies, which are separate devices, may lead the way to routine preparation and characterization of “liquid biopsies” from cancer patients. PMID:23969419
Stirling technology development at NASA GRC
NASA Astrophysics Data System (ADS)
Thieme, Lanny G.; Schreiber, Jeffrey G.; Mason, Lee S.
2002-01-01
The Department of Energy, Stirling Technology Company (STC), and NASA Glenn Research Center (GRC) are developing a free-piston Stirling convertor for a high-efficiency Stirling Radioisotope Generator (SRG) for NASA Space Science missions. The SRG is being developed for multimission use, including providing electric power for unmanned Mars rovers and deep space missions. NASA GRC is conducting an in-house technology project to assist in developing the convertor for space qualification and mission implementation. Recent testing of 55-We Technology Demonstration Convertors (TDC's) built by STC includes mapping of a second pair of TDC's, single TDC testing, and TDC electromagnetic interference and electromagnetic compatibility characterization on a non-magnetic test stand. Launch environment tests of a single TDC without its pressure vessel to better understand the convertor internal structural dynamics and of dual-opposed TDC's with several engineering mounting structures with different natural frequencies have recently been completed. A preliminary life assessment has been completed for the TDC heater head, and creep testing of the IN718 material to be used for the flight convertors is underway. Long-term magnet aging tests are continuing to characterize any potential aging in the strength or demagnetization resistance of the magnets used in the linear alternator (LA). Evaluations are now beginning on key organic materials used in the LA and piston/rod surface coatings. GRC is also conducting finite element analyses for the LA, in part to look at the demagnetization margin on the permanent magnets. The world's first known integrated test of a dynamic power system with electric propulsion was achieved at GRC when a Hall-effect thruster was successfully operated with a free-piston Stirling power source. Cleveland State University is developing a multi-dimensional Stirling computational fluid dynamics code to significantly improve Stirling loss predictions and assist in identifying convertor areas for further improvements. This paper will update the status and results for these efforts. .
Effect of thermal aging on stability of transformer oil based temperature sensitive magnetic fluids
NASA Astrophysics Data System (ADS)
Kaur, Navjot; Chudasama, Bhupendra
2018-04-01
Synthesizing stable temperature sensitive magnetic fluids with tunable magnetic properties that can be used as coolant in transformers is of great interest, however not exploited commercially due to the lack of its stability at elevated temperatures in bulk quantities. The task is quite challenging as the performance parameters of magnetic fluids are strongly influenced by thermal aging. In this article, we report the effect of thermal aging on colloidal stability and magnetic properties of Mn1-xZnxFe2O4 magnetic fluids prepared in industrial grade transformer oil. As-synthesized magnetic fluids possess good dispersion stability and tunable magnetic properties. Effect of accelerated thermal aging on the dispersion stability and magnetic properties have been evaluated by photon correlation spectroscopy and vibration sample magnetometry, respectively. Magnetic fluids are stable under accelerated aging at elevated temperatures (from 50 °C to 125 °C), which is critical for their efficient performance in high power transformers.
The role of magnetic resonance imaging and ultrasound in patients with adnexal masses.
Sohaib, S A; Mills, T D; Sahdev, A; Webb, J A W; Vantrappen, P O; Jacobs, I J; Reznek, R H
2005-03-01
To evaluate the accuracy of ultrasonography (US) and magnetic resonance imaging (MRI) in characterizing adnexal masses, and to determine which patients may benefit from MRI. We prospectively studied 72 women (mean age 53 years, range 19 to 86 years) with clinically suspected adnexal masses. A single experienced sonographer performed transabdominal and transvaginal greyscale spectral and colour Doppler examinations. MRI was carried out on a 1.5T system using T1, T2 and fat-suppressed T1-weighted sequences before and after intravenous injection of gadolinium. The adnexal masses were categorized as benign or malignant without knowledge of clinical details, according to the imaging features which were compared with the surgical and pathological findings. For characterizing lesions as malignant, the sensitivity, specificity and accuracy of MRI were 96.6%, 83.7% and 88.9%, respectively, and of US were 100%, 39.5% and 63.9%, respectively. MRI was more specific (p<0.05) than US. Both MRI and US correctly diagnosed 17 (24%) cases with benign and 28 (39%) cases with malignant masses. MRI correctly diagnosed 19 (26%) cases with benign lesion(s), which on US were thought to be malignant. The age, menopausal status and CA-125 levels in these women made benign disease likely, but US features were suggestive of malignancy (large masses and solid-cystic lesions with nodules). MRI is more specific and accurate than US and Doppler assessment for characterizing adnexal masses. Women who clinically have a relatively low risk of malignancy but who have complex sonographic features may benefit from MRI.
Magnetic massive stars as progenitors of `heavy' stellar-mass black holes
NASA Astrophysics Data System (ADS)
Petit, V.; Keszthelyi, Z.; MacInnis, R.; Cohen, D. H.; Townsend, R. H. D.; Wade, G. A.; Thomas, S. L.; Owocki, S. P.; Puls, J.; ud-Doula, A.
2017-04-01
The groundbreaking detection of gravitational waves produced by the inspiralling and coalescence of the black hole (BH) binary GW150914 confirms the existence of 'heavy' stellar-mass BHs with masses >25 M⊙. Initial characterization of the system by Abbott et al. supposes that the formation of BHs with such large masses from the evolution of single massive stars is only feasible if the wind mass-loss rates of the progenitors were greatly reduced relative to the mass-loss rates of massive stars in the Galaxy, concluding that heavy BHs must form in low-metallicity (Z ≲ 0.25-0.5 Z⊙) environments. However, strong surface magnetic fields also provide a powerful mechanism for modifying mass-loss and rotation of massive stars, independent of environmental metallicity. In this paper, we explore the hypothesis that some heavy BHs, with masses >25 M⊙ such as those inferred to compose GW150914, could be the natural end-point of evolution of magnetic massive stars in a solar-metallicity environment. Using the MESA code, we developed a new grid of single, non-rotating, solar-metallicity evolutionary models for initial zero-age main sequence masses from 40 to 80 M⊙ that include, for the first time, the quenching of the mass-loss due to a realistic dipolar surface magnetic field. The new models predict terminal-age main-sequence (TAMS) masses that are significantly greater than those from equivalent non-magnetic models, reducing the total mass lost by a strongly magnetized 80 M⊙ star during its main-sequence evolution by 20 M⊙. This corresponds approximately to the mass-loss reduction expected from an environment with metallicity Z = 1/30 Z⊙.
NASA Astrophysics Data System (ADS)
Brown, Jennifer R.; Brox, Timothy I.; Vogt, Sarah J.; Seymour, Joseph D.; Skidmore, Mark L.; Codd, Sarah L.
2012-12-01
Polycrystalline ice, as found in glaciers and the ice sheets of Antarctica, is a low porosity porous media consisting of a complicated and dynamic pore structure of liquid-filled intercrystalline veins within a solid ice matrix. In this work, Nuclear Magnetic Resonance measurements of relaxation rates and molecular diffusion, useful for probing pore structure and transport dynamics in porous systems, were used to physically characterize the unfrozen vein network structure in ice and its response to the presence of metabolic products produced by V3519-10, a cold tolerant microorganism isolated from the Vostok ice core. Recent research has found microorganisms that can remain viable and even metabolically active within icy environments at sub-zero temperatures. One potential mechanism of survival for V3519-10 is secretion of an extracellular ice binding protein that binds to the prism face of ice crystals and inhibits ice recrystallization, a coarsening process resulting in crystal growth with ice aging. Understanding the impact of ice binding activity on the bulk vein network structure in ice is important to modeling of frozen geophysical systems and in development of ice interacting proteins for biotechnology applications, such as cryopreservation of cell lines, and manufacturing processes in food sciences. Here, we present the first observations of recrystallization inhibition in low porosity ice containing V3519-10 extracellular protein extract as measured with Nuclear Magnetic Resonance and Magnetic Resonance Imaging.
Novel Magnetic Fluids for Breast Cancer Therapy
2005-04-01
synthesis and characterization efforts concerning nickel-based alloys have been reported previously [5]. Nano-material has been obtained using an inverse...gar gel d ork his task regularly accompanies the synthesis work. Characterization analysis includes size, composition, magnetic pro perties. The...currently available magnetic fluids used in hyperthermia. The specific goals are: 1. Develop a synthesis process to fabricate magnetic nano
Simões, Rui V; Muñoz-Moreno, Emma; Cruz-Lemini, Mónica; Eixarch, Elisenda; Bargalló, Núria; Sanz-Cortés, Magdalena; Gratacós, Eduard
2017-01-01
Intrauterine growth restriction and premature birth represent 2 independent problems that may occur simultaneously and contribute to impaired neurodevelopment. The objective of the study was to assess changes in the frontal lobe metabolic profiles of 1 year old intrauterine growth restriction infants born prematurely and adequate-for-gestational-age controls, both premature and term adequate for gestational age and their association with brain structural and biophysical parameters and neurodevelopmental outcome at 2 years. A total of 26 prematurely born intrauterine growth restriction infants (birthweight <10th centile for gestational age), 22 prematurely born but adequate for gestational age controls, and 26 term adequate-for-gestational-age infants underwent brain magnetic resonance imaging and magnetic resonance spectroscopy at 1 year of age during natural sleep, on a 3 Tesla scanner. All brain T1-weighted and diffusion-weighted images were acquired along with short echo time single-voxel proton spectra from the frontal lobe. Magnetic resonance imaging/magnetic resonance spectroscopy data were processed to derive structural, biophysical, and metabolic information, respectively. Neurodevelopment was evaluated at 2 years of age using the Bayley Scales 3rd edition, assessing cognitive, language, motor, socioemotional, and adaptive behavior. Prematurely born intrauterine growth restriction infants had slightly smaller brain volumes and increased frontal lobe white matter mean diffusivity compared with both prematurely born but adequate for gestational age and term adequate for gestational age controls. Frontal lobe N-acetylaspartate levels were significantly lower in prematurely born intrauterine growth restriction than in prematurely born but adequate for gestational age infants but increased in prematurely born but adequate for gestational age compared with term adequate-for-gestational-age infants. The prematurely born intrauterine growth restriction group also showed slightly lower choline compounds, borderline decrements of estimated glutathione levels, and increased myoinositol to choline ratios, compared with prematurely born but adequate for gestational age controls. These specific metabolite changes were locally correlated to lower gray matter content and increased mean diffusivity and reduced white matter fraction and fractional anisotropy. Prematurely born intrauterine growth restriction infants also showed a tendency for poorer neurodevelopmental outcome at 2 years, associated with lower levels of frontal lobe N-acetylaspartate at 1 year within the preterm subset. Preterm intrauterine growth restriction infants showed altered brain metabolite profiles during a critical stage of brain maturation, which correlate with brain structural and biophysical parameters and neurodevelopmental outcome. Our results suggest altered neurodevelopmental trajectories in preterm intrauterine growth restriction and adequate-for-gestational-age infants, compared with term adequate-for-gestational-age infants, which require further characterization. Copyright © 2016 Elsevier Inc. All rights reserved.
Aging processes in disordered materials: High-Tc superconductors and ferromagnets
NASA Astrophysics Data System (ADS)
Pleimling, Michel
2013-03-01
Physical aging is generically encountered in systems far from equilibrium that evolve with slow dynamics. Well known examples can be found in structural glasses, spin glasses, magnetic systems, and colloids. Recent years have seen major breakthroughs in our understanding of aging processes in non-disordered systems. Progress in understanding aging in disordered systems has been much slower though. In this talk I discuss non-equilibrium relaxation in two different types of disordered systems: coarsening ferromagnets with disorder, characterized by a crossover from an initial power-law like growth of domains to a slower logarithmic growth regime, and interacting vortex lines in disordered type-II superconductors, where the interplay of vortex-vortex interaction and pinning results in a very rich non-equilibrium behavior. This work is supported by the US Department of Energy through grant DE-FG02-09ER46613.
Krasnoshchekova, E I; Zykin, P A; Tkachenko, L A; Aleksandrov, T A; Sereda, V M; Yalfimov, A N
2016-10-01
The age dynamics of corpus callosum development was studied on magnetic resonance images of the brain in children aged 2-11 years without neurological abnormalities and with infantile cerebral palsy. The areas of the total corpus callosum and its segments are compared in the midsagittal images. Analysis is carried out with the use of an original formula: proportion of areas of the anterior (genu, CC2; and anterior part, CC3) and posterior (isthmus, CC6 and splenium, CC7) segments: kCC=(CC2+CC3)×CC6/CC7. The results characterize age-specific dynamics of the corpus callosum development and can be used for differentiation, with high confidence, of the brain of children without neurological abnormalities from the brain patients with infantile cerebral palsy.
Magnetic Characterization of Iron Oxide Nanoparticles for Biomedical Applications.
Maldonado-Camargo, Lorena; Unni, Mythreyi; Rinaldi, Carlos
2017-01-01
Iron oxide nanoparticles are of interest in a wide range of biomedical applications due to their response to applied magnetic fields and their unique magnetic properties. Magnetization measurements in constant and time-varying magnetic field are often carried out to quantify key properties of iron oxide nanoparticles. This chapter describes the importance of thorough magnetic characterization of iron oxide nanoparticles intended for use in biomedical applications. A basic introduction to relevant magnetic properties of iron oxide nanoparticles is given, followed by protocols and conditions used for measurement of magnetic properties, along with examples of data obtained from each measurement, and methods of data analysis.
1H magnetic resonance spectroscopy in monocarboxylate transporter 8 gene deficiency.
Sijens, Paul E; Rödiger, Lars A; Meiners, Linda C; Lunsing, Roelineke J
2008-05-01
In monocarboxylate transporter 8 (MCT8) gene deficiency, a syndrome combining thyroid and neurological abnormalities, the central nervous system has not yet been characterized by magnetic resonance (MR) spectroscopy. We studied whether the degree of dysmyelinization in MCT8 gene deficiency according to MR imaging (MRI) is coupled with abnormalities in brain metabolism. MRI and MR spectroscopy of the brain were performed twice in two MCT8 gene deficiency patients, for the first time at age 8-10 months and for the second time at age 17-28 months. The results were compared with those obtained in controls of a similar age. Compared with controls, young children with MCT8 show choline and myoinositol level increases and N-acetyl aspartate decreases in supraventricular gray and white matter, phenomena associated with the degree of dysmyelinization according to MRI. MCT8 gene deficiency results in deviant myelinization and general atrophy, which is substantiated by the MR spectroscopy findings of increased choline and myoinositol levels and decreased N-acetyl aspartate. The observations suggest that different mutations in the MCT8 gene lead to differences in the severity of the clinical spectrum, dysmyelinization, and MR spectroscopy-detectable changes in brain metabolism.
NASA Technical Reports Server (NTRS)
Honess, Shawn B. (Inventor); Narvaez, Pablo (Inventor); Mcauley, James M. (Inventor)
1992-01-01
An apparatus for characterizing the magnetic field of a device under test is discussed. The apparatus is comprised of five separate devices: (1) a device for nullifying the ambient magnetic fields in a test environment area with a constant applied magnetic field; (2) a device for rotating the device under test in the test environment area; (3) a device for sensing the magnetic field (to obtain a profile of the magnetic field) at a sensor location which is along the circumference of rotation; (4) a memory for storing the profiles; and (5) a processor coupled to the memory for characterizing the magnetic field of the device from the magnetic field profiles thus obtained.
NASA Astrophysics Data System (ADS)
Ahmad, Farooq; Dennis, John Ojur; Md Khir, Mohd Haris; Hamid, Nor Hisham
2012-09-01
This paper presents the calibration of Helmholtz coils for the characterization of MEMS Magnetic sensor using Fluxgate magnetometer with DAS1 Magnetic Range Data Acquisition System. The Helmholtz coils arrangement is often used to generate a uniform magnetic field in space. In the past, standard magnets were used to calibrate the Helmholtz coils. A method is presented here for calibrating these coils using a Fluxgate magnetometer and known current source, which is easier and results in greater accuracy.
Microstructure, Corrosion and Magnetic Behavior of an Aged Dual-Phase Stainless Steel
NASA Astrophysics Data System (ADS)
Ziouche, A.; Haddad, A.; Badji, R.; Zergoug, M.; Zoubiri, N.; Bedjaoui, W.; Abaidia, S.
2018-03-01
In the present work, the effect of the precipitation phenomena on corrosion and magnetic behavior of an aged dual-phase stainless steel was investigated. Aging treatment caused the precipitation of the σ phase, chromium carbides and secondary austenite, which was accompanied by the shifting of the δ/γ interfaces inside the δ ferrite grains. Aging between 700 and 850 °C strongly deteriorated the pitting corrosion resistance of the studied material. Magnetic investigation of the aged material using the vibration sample magnetic technique revealed the sensitivity of the intrinsic magnetic properties to the smallest microstructural change. This was confirmed by the Eddy current technique that led also to the evaluation of the aging-induced localized corrosion.
Eddy current-shielded x-space relaxometer for sensitive magnetic nanoparticle characterization
Bauer, L. M.; Hensley, D. W.; Zheng, B.; Tay, Z. W.; Goodwill, P. W.; Griswold, M. A.; Conolly, S. M.
2016-01-01
The development of magnetic particle imaging (MPI) has created a need for optimized magnetic nanoparticles. Magnetic particle relaxometry is an excellent tool for characterizing potential tracers for MPI. In this paper, we describe the design and construction of a high-throughput tabletop relaxometer that is able to make sensitive measurements of MPI tracers without the need for a dedicated shield room. PMID:27250472
Eddy current-shielded x-space relaxometer for sensitive magnetic nanoparticle characterization.
Bauer, L M; Hensley, D W; Zheng, B; Tay, Z W; Goodwill, P W; Griswold, M A; Conolly, S M
2016-05-01
The development of magnetic particle imaging (MPI) has created a need for optimized magnetic nanoparticles. Magnetic particle relaxometry is an excellent tool for characterizing potential tracers for MPI. In this paper, we describe the design and construction of a high-throughput tabletop relaxometer that is able to make sensitive measurements of MPI tracers without the need for a dedicated shield room.
NASA Astrophysics Data System (ADS)
Lucifora, Stella; Cifelli, Francesca; Mattei, Massimo; Sagnotti, Leonardo; Cosentino, Domenico; Roberts, Andrew P.
2012-10-01
We present paleomagnetic, rock magnetic and scanning electron microscope data from three upper Messinian stratigraphic sections from the Adana Basin (southern Turkey). The collected samples are from fine-grained units, which were deposited during the Messinian Salinity Crisis (within subchron C3r). Paleomagnetic results reveal an inconsistent polarity record, related to a mixture of magnetite and greigite that hinders determination of a reliable magnetostratigraphy. Three classes of samples are recognized on the basis of paleomagnetic results. The first is characterized by a single magnetization component, with normal polarity, that is stable up to 530-580°C and is carried by magnetite. The second is characterized by a single magnetization component, with reversed polarity, that is stable up to 330-420°C. This magnetization is due to greigite, which developed after formation of slumps and before tectonic tilting of the studied successions. The third is characterized by reversed polarity, which is stable up to 530-580°C. We interpret this component as a primary magnetization carried by fine-grained and magnetically stable detrital magnetite. Results indicate that in the Adana Basin the assumption that a primary magnetization is carried by magnetite, and a magnetic overprint carried by greigite, does not hold because a late magnetic overprint has also been found for magnetite-bearing samples. Our data illustrate the complexity of magnetostratigraphic reconstructions in successions characterized by variable mixtures of magnetic minerals with different magnetic stability that formed at different stages. We demonstrate the need to perform detailed magnetic mineralogy analyses when conducting magnetostratigraphic studies of clay-rich sediments from marine or lacustrine environments.
Childhood Leukemia and 50 Hz Magnetic Fields: Findings from the Italian SETIL Case-Control Study
Salvan, Alberto; Ranucci, Alessandra; Lagorio, Susanna; Magnani, Corrado
2015-01-01
We report on an Italian case-control study on childhood leukemia and exposure to extremely low frequency magnetic fields (ELF-MF). Eligible for inclusion were 745 leukemia cases, aged 0–10 years at diagnosis in 1998–2001, and 1475 sex- and age-matched population controls. Parents of 683 cases and 1044 controls (92% vs. 71%) were interviewed. ELF-MF measurements (24–48 h), in the child’s bedroom of the dwelling inhabited one year before diagnosis, were available for 412 cases and 587 controls included in the main conditional regression analyses. The magnetic field induction was 0.04 μT on average (geometric mean), with 0.6% of cases and 1.6% of controls exposed to >0.3 μT. The impact of changes in the statistical model, exposure metric, and data-set restriction criteria was explored via sensitivity analyses. No exposure-disease association was observed in analyses based on continuous exposure, while analyses based on categorical variables were characterized by incoherent exposure-outcome relationships. In conclusion, our results may be affected by several sources of bias and they are noninformative at exposure levels >0.3 μT. Nonetheless, the study may contribute to future meta- or pooled analyses. Furthermore, exposure levels among population controls are useful to estimate attributable risk. PMID:25689995
NASA Astrophysics Data System (ADS)
Ustra, A.; Kessouri, P.; Leite, A.; Mendonça, C. A.; Bandeira, N.
2017-12-01
Magnetic minerals in soils and rocks are one way to study biogechemical and paleoenvironmental processes. The ultrafine fraction of these minerals (superparmagnetic (SP) and stable single domain (SSD)) are usually investigated in environmental magnetism studies, since changes in mineralogy, concentration, size and morphology of the magnetic grains can be related to biogeochemical processes. In this study, we use low-field frequency dependent susceptibility (FDS) and isothermal remanent magnetization (IRM) to characterize the magnetic properties of materials in environmental magnetism. Magnetic susceptibility (MS) measurements are frequently used as a proxy of magnetic minerals present in soils and rocks. MS is a complex function of magnetic mineralogy and grain size, as well as magnitude and frequency of the applied field. This work presents a method for inverting low-field FDS data. The inverted parameters can be interpreted in terms of grain size variations of magnetic particles on the SP-SSD transition. This work also presents a method for inverting IRM demagnetization curves, to obtain the saturation magnetization, the individual magnetic moment for an assemblage of ultrafine SP minerals and estimate the concentration of magnetic carriers. IRM magnetization curves can be interpreted as resulting from distinct contributions of different mineral phases, which can be described by Cummulative Log-Gaussian (CLG) distributions. Each acquisition curve provides fundamental parameters that are characteristic of the respective mineral phase. The CLG decomposition is widely used in an interpretation procedure named mineral unmixing. In this work we present an inversion method for mineral unmixing, implementing the genetic algorithm to find the parameters of distinct components. These methodologies have been tested by synthetic models and applied to data from environmental magnetism studies. In this work we apply the proposed methodologies to characterize the magnetic properties of samples from the former Brandywine MD Defense Reutilization and Marketing Office (DRMO). The results from the magnetic properties characterization will provide additional information that may assist the interpretation of the biogeophysical signatures observed at the site.
DOE Office of Scientific and Technical Information (OSTI.GOV)
John, Melanie, E-mail: melanie.john@min.uni-muenchen.de; Heuss-Aßbichler, Soraya; Park, So-Hyun
This study presents a new low temperature synthesis method to obtain pure delafossite (Cu{sup 1+}Fe{sup 3+}O{sub 2}) at a temperature of 70 °C within 24 h. For the first time delafossite is synthesized solely by precipitation and subsequent ageing process and without usage of any additives controlling the oxidation state of copper. The synthesized material, called LT-delafossite, consists of pure Cu{sup 1+}Fe{sup 3+}O{sub 2} exclusive of any side products. Rietveld analysis confirms the presence of both 3R (space group (SG): R-3m) and 2H (SG: P6{sub 3}/mmc) polytypes in LT-delafossite. Electron microscopy images show nanometer-sized hexagonal plates with a diameter <500more » nm and a thickness of <30 nm. Measurements of the magnetic susceptibility from 2 K to 350 K in zero-field show one peak ∼18.5 K, which is attributed to an AFM phase transition. Zero-field-cooled magnetization data between −14 T and +14 T at 2 K revealed an s-shape form around the origin having no remanent magnetization. - Highlights: • New process: low temperature synthesis of pure CuFeO{sub 2} nanoparticles. • Synthesis at 70 °C within 24 h solely by precipitation and ageing. • Nanoparticle characterization by XRD, FTIR, SEM, ICP–OES, TEM and Mößbauer. • Special magnetic properties of nano-sized CuFeO{sub 2} synthesized at low temperatures.« less
Quantitative Characterization of Magnetic Mobility of Nanoparticle in Solution-Based Condition.
Rodoplu, Didem; Boyaci, Ismail H; Bozkurt, Akif G; Eksi, Haslet; Zengin, Adem; Tamer, Ugur; Aydogan, Nihal; Ozcan, Sadan; Tugcu-Demiröz, Fatmanur
2015-01-01
Magnetic nanoparticles are considered as the ideal substrate to selectively isolate target molecules or organisms from sample solutions in a wide variety of applications including bioassays, bioimaging and environmental chemistry. The broad array of these applications in fields requires the accurate magnetic characterization of nanoparticles for a variety of solution based-conditions. Because the freshly synthesized magnetic nanoparticles demonstrated a perfect magnetization value in solid form, they exhibited a different magnetic behavior in solution. Here, we present simple quantitative method for the measurement of magnetic mobility of nanoparticles in solution-based condition. Magnetic mobility of the nanoparticles was quantified with initial mobility of the particles using UV-vis absorbance spectroscopy in water, ethanol and MES buffer. We demonstrated the efficacy of this method through a systematic characterization of four different core-shell structures magnetic nanoparticles over three different surface modifications. The solid nanoparticles were characterized using transmission electron microscopy (TEM), X-ray diffraction (XRD) and saturation magnetization (Ms). The surfaces of the nanoparticles were functionalized with 11-mercaptoundecanoic acid and bovine serum albumin BSA was selected as biomaterial. The effect of the surface modification and solution media on the stability of the nanoparticles was monitored by zeta potentials and hydrodynamic diameters of the nanoparticles. Results obtained from the mobility experiments indicate that the initial mobility was altered with solution media, surface functionalization, size and shape of the magnetic nanoparticle. The proposed method easily determines the interactions between the magnetic nanoparticles and their surrounding biological media, the magnetophoretic responsiveness of nanoparticles and the initial mobilities of the nanoparticles.
Santos, X M; Krishnamurthy, R; Bercaw-Pratt, J L; Dietrich, J E
2012-06-01
To evaluate the utility of transabdominal ultrasound and magnetic resonance imaging in the evaluation of American Society for Reproductive Medicine (†)(ASRM)-classified müllerian anomalies compared to surgical findings in the pediatric and adolescent population. Retrospective chart review. Tertiary academic center. Thirty-eight patients with müllerian anomalies seen in our pediatric and adolescent gynecology clinic were identified both on the basis of ICD-9 codes and having magnetic resonance imaging at Texas Children's Hospital between 2004 and 2009. None. Correlation among transabdominal ultrasound and magnetic resonance imaging findings with surgical findings. Mean age was 12.2 (± 4.1) years. Twenty-eight patients underwent magnetic resonance imaging and required surgical intervention, and 88.5% demonstrated correlative consistency with surgical findings. Twenty-two patients underwent ultrasound, magnetic resonance imaging, and surgery, which revealed consistency among ultrasound and surgical findings (59.1%) and consistency among magnetic resonance imaging and surgical findings (90.9%). In ASRM diagnoses evaluated by magnetic resonance imaging, surgical findings correlated in 92% (Pearson 0.89). Overall, 55.2% of patients had a renal malformation. Magnetic resonance imaging is the gold standard imaging modality for müllerian anomalies and is an effective technique for noninvasive evaluation and accurate classification of the type of anomaly in the pediatric and adolescent population. Magnetic resonance imaging should be considered as an adjunct to transabdominal ultrasound to evaluate müllerian anomalies. Copyright © 2012 North American Society for Pediatric and Adolescent Gynecology. Published by Elsevier Inc. All rights reserved.
Crustal Magnetic Field Anomalies and Global Tectonics
NASA Astrophysics Data System (ADS)
Storetvedt, Karsten
2014-05-01
A wide variety of evidence suggests that the ruling isochron (geomagnetic polarity versus age) hypothesis of marine magnetic lineations has no merit - undermining therefore one of the central tenets of plate tectonics. Instead, variable induction by the ambient geomagnetic field is likely to be the principal agent for mega-scale crustal magnetic features - in both oceanic and continental settings. This revitalizes the fault-controlled susceptibility-contrast model of marine magnetic lineations, originally proposed in the late 1960s. Thus, the marine magnetic 'striping' may be ascribed to tectonic shearing and related, but variable, disintegration of the original iron-oxide mineralogy, having developed primarily along one of the two pan-global sets of orthogonal fractures and faults. In this way, fault zones (having the more advanced mineral alteration) would be characterized by relatively low susceptibility, while more moderately affected crustal sections (located between principal fault zones) would be likely to have less altered oxide mineralogy and therefore higher magnetic susceptibility. On this basis, induction by the present geomagnetic field is likely to produce oscillating magnetic field anomalies with axis along the principal shear grain. The modus operandi of the alternative magneto-tectonic interpretation is inertia-driven wrenching of the global Alpine age palaeo-lithosphere - triggered by changes in Earth's rotation. Increasing sub-crustal loss to the upper mantle during the Upper Mesozoic had left the ensuing Alpine Earth in a tectonically unstable state. Thus, sub-crustal eclogitization and associated gravity-driven delamination to the upper mantle led to a certain degree of planetary acceleration which in turn gave rise to latitude-dependent, westward inertial wrenching of the global palaeo-lithosphere. During this process, 1) the thin and mechanically fragile oceanic crust were deformed into a new type of broad fold belts, and 2) the continents were subjected to relative 'in situ' rotations (mostly moderate). Examples of marine magnetic lineations with landward continuation along prominent transcurrent fault zones, and the fact that striped marine magnetic anomalies may display orthogonal networks - concordant with the ubiquitous system of rectilinear fractures, faults and joints - corroborate the wrench tectonic interpretation of crustal field anomalies.
Spin-polarized scanning tunneling microscopy with quantitative insights into magnetic probes
NASA Astrophysics Data System (ADS)
Phark, Soo-hyon; Sander, Dirk
2017-04-01
Spin-polarized scanning tunneling microscopy and spectroscopy (spin-STM/S) have been successfully applied to magnetic characterizations of individual nanostructures. Spin-STM/S is often performed in magnetic fields of up to some Tesla, which may strongly influence the tip state. In spite of the pivotal role of the tip in spin-STM/S, the contribution of the tip to the differential conductance d I/d V signal in an external field has rarely been investigated in detail. In this review, an advanced analysis of spin-STM/S data measured on magnetic nanoislands, which relies on a quantitative magnetic characterization of tips, is discussed. Taking advantage of the uniaxial out-of-plane magnetic anisotropy of Co bilayer nanoisland on Cu(111), in-field spin-STM on this system has enabled a quantitative determination, and thereby, a categorization of the magnetic states of the tips. The resulting in-depth and conclusive analysis of magnetic characterization of the tip opens new venues for a clear-cut sub-nanometer scale spin ordering and spin-dependent electronic structure of the non-collinear magnetic state in bilayer high Fe nanoislands on Cu(111).
Iacovacci, V; Lucarini, G; Innocenti, C; Comisso, N; Dario, P; Ricotti, L; Menciassi, A
2015-12-01
This work reports the fabrication, magnetic characterization and controlled navigation of film-shaped microrobots consisting of a polydimethylsiloxane-NdFeB powder composite material. The fabrication process relies on spin-coating deposition, powder orientation and permanent magnetization. Films with different powder concentrations (10 %, 30 %, 50 % and 70 % w/w) were fabricated and characterized in terms of magnetic properties and magnetic navigation performances (by exploiting an electromagnet-based platform). Standardized data are provided, thus enabling the exploitation of these composite materials in a wide range of applications, from MEMS/microrobot development to biomedical systems. Finally, the possibility to microfabricate free-standing polymeric structures and the biocompatibility of the proposed composite materials is demonstrated.
Characterization of magnetic colloids by means of magnetooptics.
Baraban, L; Erbe, A; Leiderer, P
2007-05-01
A new, efficient method for the characterization of magnetic colloids based on the Faraday effect is proposed. According to the main principles of this technique, it is possible to detect the stray magnetic field of the colloidal particles induced inside the magnetooptical layer. The magnetic properties of individual particles can be determined providing measurements in a wide range of magnetic fields. The magnetization curves of capped colloids and paramagnetic colloids were measured by means of the proposed approach. The registration of the magnetooptical signals from each colloidal particle in an ensemble permits the use of this technique for testing the magnetic monodispersity of colloidal suspensions.
Processing of MnBi bulk magnets with enhanced energy product
Poudyal, Narayan; Liu, Xubo; Wang, Wei; ...
2016-02-23
Here, we report magnetic properties and microstructure of high energy-product MnBi bulk magnets fabricated by low-temperature ball-milling and warm compaction technique. A maximum energy product (BH) max of 8.4 MGOe and a coercivity of 6.2 kOe were obtained in the bulk MnBi magnet at room temperature. Magnetic characterization at elevated temperatures showed an increase in coercivity to 16.2 kOe while (BH) max value decreased to 6.8 MGOe at 400 K. Microstructure characterization revealed that the bulk magnets consist of oriented uniform nanoscale grains with average size about 50 nm.
Reward anticipation in the adolescent and aging brain.
Lorenz, Robert C; Gleich, Tobias; Beck, Anne; Pöhland, Lydia; Raufelder, Diana; Sommer, Werner; Rapp, Michael A; Kühn, Simone; Gallinat, Jürgen
2014-10-01
Processing of reward is the basis of adaptive behavior of the human being. Neural correlates of reward processing seem to be influenced by developmental changes from adolescence to late adulthood. The aim of this study is to uncover these neural correlates during a slot machine gambling task across the lifespan. Therefore, we used functional magnetic resonance imaging to investigate 102 volunteers in three different age groups: 34 adolescents, 34 younger adults, and 34 older adults. We focused on the core reward areas ventral striatum (VS) and ventromedial prefrontal cortex (VMPFC), the valence processing associated areas, anterior cingulate cortex (ACC) and insula, as well as information integration associated areas, dorsolateral prefrontal cortex (DLPFC), and inferior parietal lobule (IPL). Results showed that VS and VMPFC were characterized by a hyperactivation in adolescents compared with younger adults. Furthermore, the ACC and insula were characterized by a U-shape pattern (hypoactivation in younger adults compared with adolescents and older adults), whereas the DLPFC and IPL were characterized by a J-shaped form (hyperactivation in older adults compared with younger groups). Furthermore, a functional connectivity analysis revealed an elevated negative functional coupling between the inhibition-related area rIFG and VS in younger adults compared with adolescents. Results indicate that lifespan-related changes during reward anticipation are characterized by different trajectories in different reward network modules and support the hypothesis of an imbalance in maturation of striatal and prefrontal cortex in adolescents. Furthermore, these results suggest compensatory age-specific effects in fronto-parietal regions. Copyright © 2014 Wiley Periodicals, Inc.
Influence of number and depth of magnetic mirror on Alfvénic gap eigenmode
NASA Astrophysics Data System (ADS)
Chang, Lei; Hu, Ning; Yao, Jianyao
2016-10-01
Alfvénic gap eigenmode (AGE) can eject energetic particles from confinement and thereby threaten the success of magnetically controlled fusion. A low-temperature plasma cylinder is a promising candidate to study this eigenmode, due to easy diagnostic access and simple geometry, and the idea is to arrange a periodic array of magnetic mirrors along the plasma cylinder and introduce a local defect to break the field periodicity. The present work validates this idea by reproducing a clear AGE inside a spectral gap, and more importantly details the influence of the number and depth (or modulation factor) of magnetic mirror on the characteristics of AGE. Results show that AGE is suppressed by other modes inside the spectral gap when the number of magnetic mirrors is below a certain value, which leads to a weakened Bragg’s effect. The structure and frequency of AGE remain unchanged for a decreased number of magnetic mirrors, as long as this number is enough for the AGE formation. The width of spectral gap and decay constant (inverse of decay length) of AGE are linearly proportional to the depth of magnetic mirror, implying easier observation of AGE through a bigger mirror depth. The frequency of AGE shifts to a lower range with the depth increased, possibly due to the unfrozen plasma with field line and the invalidity of small-perturbation analysis. Nevertheless, it is exciting to find that the depth of field modulation can be increased to form AGE for a very limited number of magnetic mirrors. This is of particular interest for the experimental implementation of AGE on a low-temperature plasma cylinder with limited length. Project supported by the National Natural Science Foundation of China (Grant Nos. 11405271, 11372104, 75121543, 11332013, 11372363, and 11502037).
NASA Astrophysics Data System (ADS)
Do, Bao Phuong Huu; Dung Nguyen, Ba; Duy Nguyen, Hoang; Nguyen, Phuong Tung
2013-12-01
We report the synthesis of magnetic iron oxide nanoparticles encapsulated in maleic acid-2-acrylamido-2-methyl-1-propanesulfonate based polymer. This composite nanoparticle is specified for the high-pressure/high-temperature (HPHT) oilfield scale inhibition application. The process includes a facile-ultrasound-supported addition reaction to obtain iron oxide nanoparticles with surface coated by oleic acid. Then via inverse microemulsion polymerization with selected monomers, the specifically designed copolymers have been formatted in nanoscale. The structure and morphology of obtained materials were characterized by transmission electron microscopy (TEM), x-ray powder diffraction (XRD), Fourier transform infrared spectroscopy (FTIR) and the thermal stability. The effectiveness of synthesized compounds as a carbonate scale inhibitor was investigated by testing method NACE standard TM 03-074-95 at aging temperature of 70, 90 and 120 °C. The magnetic nanocomposite particles can be easily collected and detected demonstrating their superior monitoring ability, which is absent in the case of conventional copolymer-based scale inhibitor.
Physical aging in graphite/epoxy composites
NASA Technical Reports Server (NTRS)
Kong, E. S. W.
1983-01-01
Sub-Tg annealing has been found to affect the properties of graphite/epoxy composites. The network epoxy studied was based on the chemistry of tetraglycidyl 4,4'-diamino-diphenyl methane (TGDDM) crosslinked by 4,4'-diamino-diphenyl sulfone (DDS). Differential scanning calorimetry, thermal mechanical analysis, and solid-state cross-polarized magic-angle-spinning nuclear magnetic resonance spectroscopy have been utilized in order to characterize this process of recovery towards thermodynamic equilibrium. The volume and enthalpy recovery as well as the 'thermoreversibility' aspects of the physical aging are discussed. This nonequilibrium and time-dependent behavior of network epoxies are considered in view of the increasingly wide applications of TGDDM-DDS epoxies as matrix materials of structural composites in the aerospace industry.
Cherubini, Andrea; Caligiuri, Maria Eugenia; Peran, Patrice; Sabatini, Umberto; Cosentino, Carlo; Amato, Francesco
2016-09-01
This study presents a voxel-based multiple regression analysis of different magnetic resonance image modalities, including anatomical T1-weighted, T2(*) relaxometry, and diffusion tensor imaging. Quantitative parameters sensitive to complementary brain tissue alterations, including morphometric atrophy, mineralization, microstructural damage, and anisotropy loss, were compared in a linear physiological aging model in 140 healthy subjects (range 20-74 years). The performance of different predictors and the identification of the best biomarker of age-induced structural variation were compared without a priori anatomical knowledge. The best quantitative predictors in several brain regions were iron deposition and microstructural damage, rather than macroscopic tissue atrophy. Age variations were best resolved with a combination of markers, suggesting that multiple predictors better capture age-induced tissue alterations. The results of the linear model were used to predict apparent age in different regions of individual brain. This approach pointed to a number of novel applications that could potentially help highlighting areas particularly vulnerable to disease.
Sm and Y radiolabeled magnetic fluids: magnetic and magneto-optical characterization
NASA Astrophysics Data System (ADS)
Aquino, R.; Gomes, J. A.; Tourinho, F. A.; Dubois, E.; Perzynski, R.; da Silva, G. J.; Depeyrot, J.
2005-03-01
We report on magnetic fluids based on samarium and ytrium-doped nanoparticles. The nanostructures chemical composition is checked and X-ray diffraction provides both their mean size and a structural characterization. Magnetization and magneto-optical birefringence results are presented and well agree with the pure maghemite behavior. Since these particles can become radioactive after neutron activation, they could therefore represent a new perspective for biomedical applications in the radiation therapy of cancer.
NASA Astrophysics Data System (ADS)
Terada, Y.; Kono, S.; Ishizawa, K.; Inamura, S.; Uchiumi, T.; Tamada, D.; Kose, K.
2013-05-01
We adopted a combination of pieces of permanent magnets and a single-channel (SC) shim coil to shim the magnetic field in a magnetic resonance imaging system dedicated for skeletal age assessment of children. The target magnet was a 0.3-T open and compact permanent magnet tailored to the hand imaging of young children. The homogeneity of the magnetic field was first improved by shimming using pieces of permanent magnets. The residual local inhomogeneity was then compensated for by shimming using the SC shim coil. The effectiveness of the shimming was measured by imaging the left hands of human subjects and evaluating the image quality. The magnetic resonance images for the child subject clearly visualized anatomical structures of all bones necessary for skeletal age assessment, demonstrating the usefulness of combined shimming.
Terada, Y; Kono, S; Ishizawa, K; Inamura, S; Uchiumi, T; Tamada, D; Kose, K
2013-05-01
We adopted a combination of pieces of permanent magnets and a single-channel (SC) shim coil to shim the magnetic field in a magnetic resonance imaging system dedicated for skeletal age assessment of children. The target magnet was a 0.3-T open and compact permanent magnet tailored to the hand imaging of young children. The homogeneity of the magnetic field was first improved by shimming using pieces of permanent magnets. The residual local inhomogeneity was then compensated for by shimming using the SC shim coil. The effectiveness of the shimming was measured by imaging the left hands of human subjects and evaluating the image quality. The magnetic resonance images for the child subject clearly visualized anatomical structures of all bones necessary for skeletal age assessment, demonstrating the usefulness of combined shimming. Copyright © 2013 Elsevier Inc. All rights reserved.
NASA Technical Reports Server (NTRS)
Zhou, Andy F.; Erwin, J. Kevin; Mansuripur, M.
1992-01-01
A new and comprehensive dielectric tensor characterization instrument is presented for characterization of magneto-optical recording media and non-magnetic thin films. Random and systematic errors of the system are studied. A series of TbFe, TbFeCo, and Co/Pt samples with different composition and thicknesses are characterized for their optical and magneto-optical properties. The optical properties of several non-magnetic films are also measured.
Short-Term Aging of NeFeB Magnets for Stirling Linear Alternator Applications
NASA Technical Reports Server (NTRS)
Niedra, Janis M.; Schwarze, Gene E. (Technical Monitor)
2001-01-01
NeFeB type magnets have been proposed for use in free piston Stirling engine driven, linear alternators to generate electric power during long duration space missions. These type of materials provide the highest energy product commercial magnets, thus minimizing alternator size or mass, but do not provide the high temperature stability of magnetic properties found in the SmCo type magnets. Therefore, to apply the NeFeB type magnets at elevated temperatures to multiyear space missions, their long-term aging characteristics must be determined. This report presents 200 hr aging data for six types of NeFeB magnets selected from three manufacturers. Aging was performed under vacuum at 150 C, with a steady demagnetizing field of 5 kOe applied. From the data produced by this short-term aging run, candidate magnet types were selected for a planned 12,000 hr long-term run. Depending on the manufacturer's magnet type, remanence losses observed ranged from 0 to 7%, when measured at 120 C on an established recoil line. Also, intrinsic coercivity losses up to about 4% were observed for the M-H curve at 120 C. In some cases, these coercivity losses were not recoverable by recharge of the magnet, indicating a structural change of the material.
NASA Astrophysics Data System (ADS)
Jayapala Rao, G. V. S.; Prasad, T. N. V. K. V.; Shameer, Syed; Arun, T.; Purnachandra Rao, M.
2017-10-01
Biosynthesis of nanoscale materials has its own advantages over other physical and chemical methods. Using soapnut extract as reducing and stabilizing agent for the synthesis of inorganic nanoscale materials is novel and has not been exploited to its potential so far. Herein, we report for the first time on the effects of sulphur substitution on soapnut extract-mediated synthesis of nanoscale NdFeB (S-NdFeB) permanent magnetic powders (Nd 15%, Fe 77.5%, B 7.5% and S with molar ratios: 0.1, 0.2, 0.3, 0.4, and 0.5). To synthesize, a 10 ml of 10% soapnut extract was added to 90 ml of respective chemical composition and heated to 60 °C for 30 min and aged for 24 h. The dried powder was sintered at 500 °C for 1 h. The characterization of the as-prepared nanoscale S-NdFeB magnetic materials was done using the techniques such as X-ray diffraction (XRD), scanning electron microscopy (SEM) with energy dispersion spectroscopy (EDS), Fourier transform infrared spectroscopy (FT-IR), dynamic light scattering (DLS for size and zeta potential measurements) and vibrating sample magnetometer (VSM)-hysteresis loop studies. The results revealed that particles were highly stable (with a negative zeta potential of 25.7 mV) with irregular and spherical shape (with measured hydrodynamic diameter 6.7 and 63.5 nm). The tetragonal structures of the formed powders were revealed by XRD micrographs. Hysteresis loop studies clearly indicate the effect of S concentration on the enhanced magnetization of the materials.
NASA Astrophysics Data System (ADS)
Emeriau-Viard, Constance; Brun, Allan Sacha
2017-10-01
During the PMS, structure and rotation rate of stars evolve significantly. We wish to assess the consequences of these drastic changes on stellar dynamo, internal magnetic field topology and activity level by mean of HPC simulations with the ASH code. To answer this question, we develop 3D MHD simulations that represent specific stages of stellar evolution along the PMS. We choose five different models characterized by the radius of their radiative zone following an evolutionary track, from 1 Myr to 50 Myr, computed by a 1D stellar evolution code. We introduce a seed magnetic field in the youngest model and then we spread it through all simulations. First of all, we study the consequences that the increase of rotation rate and the change of geometry of the convective zone have on the dynamo field that exists in the convective envelop. The magnetic energy increases, the topology of the magnetic field becomes more complex and the axisymmetric magnetic field becomes less predominant as the star ages. The computation of the fully convective MHD model shows that a strong dynamo develops with a ratio of magnetic to kinetic energy reaching equipartition and even super-equipartition states in the faster rotating cases. Magnetic fields resulting from our MHD simulations possess a mixed poloidal-toroidal topology with no obvious dominant component. We also study the relaxation of the vestige dynamo magnetic field within the radiative core and found that it satisfies stability criteria. Hence it does not experience a global reconfiguration and instead slowly relaxes by retaining its mixed poloidal-toroidal topology.
NASA Astrophysics Data System (ADS)
Alosmanov, R. M.; Szuwarzyński, M.; Schnelle-Kreis, J.; Matuschek, G.; Magerramov, A. M.; Azizov, A. A.; Zimmermann, R.; Zapotoczny, S.
2018-04-01
Fabrication of magnetic nanocomposites containing iron oxide nanoparticles formed in situ within a phosphorus-containing polymer matrix as well as its structural characterization and its thermal degradation is reported here. Comparative structural studies of the parent polymer and nanocomposites were performed using FTIR spectroscopy, x-ray diffraction, and atomic force microscopy. The results confirmed the presence of dispersed iron oxide magnetic nanoparticles in the polymer matrix. The formed composite combines the properties of porous polymer carriers and magnetic particles enabling easy separation and reapplication of such polymeric carriers used in, for example, catalysis or environmental remediation. Studies on thermal degradation of the composites revealed that the process proceeds in three stages while a significant influence of the embedded magnetic particles on that process was observed in the first two stages. Magnetic force microscopy studies revealed that nanocomposites and its calcinated form have strong magnetic properties. The obtained results provide a comprehensive characterization of magnetic nanocomposites and the products of their calcination that are important for their possible applications as sorbents (regeneration conditions, processing temperature, disposal, etc).
Wang, Ligong; Salibi, Nouha; Chang, Gregory; Bencardino, Jenny T.; Babb, James S.; Rokito, Andrew; Jazrawi, Laith; Sherman, Orrin; Regatte, Ravinder R.
2014-01-01
Rationale and Objectives The objectives of this study were to investigate the changes in compartment-specific subchondral bone marrow lipids of femoral–tibial bone in acute anterior cruciate ligament (ACL)-injured patients compared to that of healthy volunteers and patients with osteoarthritis (OA) (Kellgren–Lawrence [KL] grade 2–3). Materials and Methods A total of 55 subjects were recruited in the study and subdivided into three subgroups: 17 healthy controls (4 females, 13 males; mean age = 41 ± 16, age range 24–78 years), 17 patients with acute ACL injury (3 females, 14 males; mean age = 30 ± 11, age range 18–61 years), and 21 patients with KL2–3 OA (12 females, 9 males; mean age = 65 ± 12, age range 44–89 years). Routine clinical proton density–weighted fast spin echo images in sagittal (without fat saturation), axial, and coronal (fat saturation) planes were acquired on a 3 T clinical scanner for cartilage morphology using Whole-Organ Magnetic Resonance Imaging Score grading. A voxel of 10 × 10 × 10 mm3 was positioned in the medial and lateral compartments of the tibia and femur for proton magnetic resonance spectroscopy measurements using the single voxel stimulated echo acquisition mode pulse sequence. All proton magnetic resonance data were processed with Java-based magnetic resonance user interface. Wilcoxon rank sum test and mixed model two-way analysis of variance were performed to determine significant differences between different compartments and examine the effect of ACL injury, OA grade and compartment, and their interactions. Results The index of unsaturation in lateral tibial compartment in ACL-injured patients was significantly higher (P < .05) than all compartments except lateral femoral in patients with KL2–3 OA. Significantly lower values (P < .05) were also identified in saturated lipids at 2.03 ppm in all compartments in ACL-injured patients than those of all compartments in patients with KL2–3 OA. Conclusions The preliminary results suggest that the indices of unsaturation in the lateral tibial compartment and the peaks of saturated lipids at 1.3 and 2.03 ppm in medial tibial compartment may be clinically useful to characterize subchondral bone marrow among healthy controls, acute ACL-injured patients, and patients with OA. PMID:24717549
Wang, Ligong; Salibi, Nouha; Chang, Gregory; Bencardino, Jenny T; Babb, James S; Rokito, Andrew; Jazrawi, Laith; Sherman, Orrin; Regatte, Ravinder R
2014-06-01
The objectives of this study were to investigate the changes in compartment-specific subchondral bone marrow lipids of femoral-tibial bone in acute anterior cruciate ligament (ACL)-injured patients compared to that of healthy volunteers and patients with osteoarthritis (OA) (Kellgren-Lawrence [KL] grade 2-3). A total of 55 subjects were recruited in the study and subdivided into three subgroups: 17 healthy controls (4 females, 13 males; mean age = 41 ± 16, age range 24-78 years), 17 patients with acute ACL injury (3 females, 14 males; mean age = 30 ± 11, age range 18-61 years), and 21 patients with KL2-3 OA (12 females, 9 males; mean age = 65 ± 12, age range 44-89 years). Routine clinical proton density-weighted fast spin echo images in sagittal (without fat saturation), axial, and coronal (fat saturation) planes were acquired on a 3 T clinical scanner for cartilage morphology using Whole-Organ Magnetic Resonance Imaging Score grading. A voxel of 10 × 10 × 10 mm(3) was positioned in the medial and lateral compartments of the tibia and femur for proton magnetic resonance spectroscopy measurements using the single voxel stimulated echo acquisition mode pulse sequence. All proton magnetic resonance data were processed with Java-based magnetic resonance user interface. Wilcoxon rank sum test and mixed model two-way analysis of variance were performed to determine significant differences between different compartments and examine the effect of ACL injury, OA grade and compartment, and their interactions. The index of unsaturation in lateral tibial compartment in ACL-injured patients was significantly higher (P < .05) than all compartments except lateral femoral in patients with KL2-3 OA. Significantly lower values (P < .05) were also identified in saturated lipids at 2.03 ppm in all compartments in ACL-injured patients than those of all compartments in patients with KL2-3 OA. The preliminary results suggest that the indices of unsaturation in the lateral tibial compartment and the peaks of saturated lipids at 1.3 and 2.03 ppm in medial tibial compartment may be clinically useful to characterize subchondral bone marrow among healthy controls, acute ACL-injured patients, and patients with OA. Copyright © 2014 AUR. Published by Elsevier Inc. All rights reserved.
Gray, Calum; MacGillivray, Thomas J; Eeley, Clare; Stephens, Nathan A; Beggs, Ian; Fearon, Kenneth C; Greig, Carolyn A
2011-02-01
Sarcopenia and cachexia are characterized by infiltration of non-contractile tissue within muscle which influences area and volume measurements. We applied a statistical clustering (k-means) technique to magnetic resonance (MR) images of the quadriceps of young and elderly healthy women and women with cancer to objectively separate the contractile and non-contractile tissue compartments. MR scans of the thigh were obtained for 34 women (n = 16 young, (median) age 26 y; n = 9 older, age 80 y; n = 9 upper gastrointestinal cancer patients, age 65 y). Segmented regions of consecutive axial images were used to calculate cross-sectional area and (gross) volume. The k-means unsupervised algorithm was subsequently applied to the MR binary mask image array data with resultant volumes compared between groups. Older women and women with cancer had 37% and 48% less quadriceps muscle respectively than young women (p < 0.001). Application of k-means subtracted a significant 9%, 14% and 20% non-contractile tissue from the quadriceps of young, older and patient groups respectively (p < 0.001). There was a significant effect of group (i.e., cancer vs healthy) when controlling for age as a covariate (p = 0.003). K-means objectively separates contractile and non-contractile tissue components. Women with upper GI cancer have significant fatty infiltration throughout whole muscle groups which is maintained when controlling for age. Copyright © 2010 Elsevier Ltd and European Society for Clinical Nutrition and Metabolism. All rights reserved.
NASA Astrophysics Data System (ADS)
Liu, Xianqiao; Kaminski, Michael D.; Riffle, Judy S.; Chen, Haitao; Torno, Michael; Finck, Martha R.; Taylor, LaToyia; Rosengart, Axel J.
2007-04-01
This paper describes a single emulsion-solvent evaporation protocol to prepare PEGylated biodegradable/biocompatible magnetic carriers by utilizing hydrophobic magnetite and a mixture of poly( D,L lactide-co-glycolide) (PLGA) and poly(lactic acid-block-polyethylene glycol) (PLA-PEG) (26:1 by mass) polymers. We characterized the magnetic microspheres in terms of morphology, composite microstructure, size and size distribution, and magnetic properties. Results show that the preparation produces magnetic microspheres with a good spherical morphology, small size (mean diameter of 1.2-1.5 μm) by means of large size distributions, and magnetizations up to 20-30 emu/g of microspheres.
NASA Astrophysics Data System (ADS)
van Reenen, Alexander; Gao, Yang; Bos, Arjen H.; de Jong, Arthur M.; Hulsen, Martien A.; den Toonder, Jaap M. J.; Prins, Menno W. J.
2013-07-01
The application of magnetic particles in biomedical research and in-vitro diagnostics requires accurate characterization of their magnetic properties, with single-particle resolution and good statistics. Here, we report intra-pair magnetophoresis as a method to accurately quantify the field-dependent magnetic moments of magnetic particles and to rapidly generate histograms of the magnetic moments with good statistics. We demonstrate our method with particles of different sizes and from different sources, with a measurement precision of a few percent. We expect that intra-pair magnetophoresis will be a powerful tool for the characterization and improvement of particles for the upcoming field of particle-based nanobiotechnology.
Coupled aging effects in nanofiber-reinforced siloxane foams
Labouriau, Andrea; Robison, Tom; Geller, Drew Adam; ...
2018-01-11
Here, this study investigates the combined effects of ionizing radiation and thermal treatments on the aging of siloxane foams containing small amounts of carbon nanofibers. Our siloxane foams were exposed to accelerated aging conditions for more than two years, resulting in very low dose rates. In addition, foams were aged under compressive load to evaluate the strength of the porous microstructure. Samples were characterized by differential scanning calorimetry (DSC), thermogravimetric analysis (TGA), Fourier transform infrared spectroscopy (FTIR), nuclear magnetic resonance spectroscopy (NMR), Mössbauer, mass spectroscopy, electron paramagnetic resonance spectroscopy (EPR), solvent swelling, imaging techniques, uniaxial compressive load testing and tearmore » testing. No significant changes in thermal stability or chemistry of the accelerated aged foam were observed, although gas evolution was detected. Changes in crystallization levels at low temperatures, microstructure, and mechanical properties were observed for foams with and without carbon nanofibers. In particular, foams aged under compressive load showed irreversible deformation of the porous microstructure. This study demonstrates that aging effects were enhanced when thermal and radiolysis were coupled together and that the addition of carbon nanofibers did not improve aging effects.« less
Coupled aging effects in nanofiber-reinforced siloxane foams
DOE Office of Scientific and Technical Information (OSTI.GOV)
Labouriau, Andrea; Robison, Tom; Geller, Drew Adam
Here, this study investigates the combined effects of ionizing radiation and thermal treatments on the aging of siloxane foams containing small amounts of carbon nanofibers. Our siloxane foams were exposed to accelerated aging conditions for more than two years, resulting in very low dose rates. In addition, foams were aged under compressive load to evaluate the strength of the porous microstructure. Samples were characterized by differential scanning calorimetry (DSC), thermogravimetric analysis (TGA), Fourier transform infrared spectroscopy (FTIR), nuclear magnetic resonance spectroscopy (NMR), Mössbauer, mass spectroscopy, electron paramagnetic resonance spectroscopy (EPR), solvent swelling, imaging techniques, uniaxial compressive load testing and tearmore » testing. No significant changes in thermal stability or chemistry of the accelerated aged foam were observed, although gas evolution was detected. Changes in crystallization levels at low temperatures, microstructure, and mechanical properties were observed for foams with and without carbon nanofibers. In particular, foams aged under compressive load showed irreversible deformation of the porous microstructure. This study demonstrates that aging effects were enhanced when thermal and radiolysis were coupled together and that the addition of carbon nanofibers did not improve aging effects.« less
Ferrari, Priscileila Colerato; dos Santos Grossklauss, Dany Bruno Borella; Alvarez, Matheus; Paixão, Fabiano Carlos; Andreis, Uilian; Crispim, Alexandre Giordano; de Castro, Ana Dóris; Evangelista, Raul Cesar; de Arruda Miranda, José Ricardo
2014-08-01
Alternating Current Biosusceptometry is a magnetically method used to characterize drug delivery systems. This work presents a system composed by an automated ACB sensor to acquire magnetic images of floating tablets. The purpose of this study was to use an automated Alternating Current Biosusceptometry (ACB) to characterize magnetic floating tablets for controlled drug delivery. Floating tablets were prepared with hydroxypropyl methylcellulose (HPMC) as hydrophilic gel material, sodium bicarbonate as gas-generating agent and ferrite as magnetic marker. ACB was used to characterize the floating lag time and the tablet hydration rate, by quantification of the magnetic images to magnetic area. Besides the buoyancy, the floating tablets were evaluated for weight uniformity, hardness, swelling and in vitro drug release. The optimized tablets were prepared with equal amounts of HPMC and ferrite, and began to float within 4 min, maintaining the flotation during more than 24 h. The data of all physical parameters lied within the pharmacopeial limits. Drug release at 24 h was about 40%. The ACB results showed that this study provided a new approach for in vitro investigation of controlled-release dosage forms. Moreover, using automated ACB will also be possible to test these parameters in humans allowing to establish an in vitro.in vivo correlation (IVIVC).
NASA Astrophysics Data System (ADS)
Huang, Pin-Chieh; Pande, Paritosh; Shelton, Ryan L.; Joa, Frank; Moore, Dave; Gillman, Elisa; Kidd, Kimberly; Nolan, Ryan M.; Odio, Mauricio; Carr, Andrew; Boppart, Stephen A.
2017-03-01
Influenced by both the intrinsic viscoelasticity of the tissue constituents and the time-evolved redistribution of fluid within the tissue, the biomechanical response of skin can reflect not only localized pathology but also systemic physiology of an individual. While clinical diagnosis of skin pathologies typically relies on visual inspection and manual palpation, a more objective and quantitative approach for tissue characterization is highly desirable. Optical coherence tomography (OCT) is an interferometry-based imaging modality that enables in vivo assessment of cross-sectional tissue morphology with micron-scale resolution, which surpasses those of most standard clinical imaging tools, such as ultrasound imaging and magnetic resonance imaging. This pilot study investigates the feasibility of characterizing the biomechanical response of in vivo human skin using OCT. OCT-based quantitative metrics were developed and demonstrated on the human subject data, where a significant difference between deformed and nondeformed skin was revealed. Additionally, the quantified postindentation recovery results revealed differences between aged (adult) and young (infant) skin. These suggest that OCT has the potential to quantitatively assess the mechanically perturbed skin as well as distinguish different physiological conditions of the skin, such as changes with age or disease.
A polyvalent harmonic coil testing method for small-aperture magnets
NASA Astrophysics Data System (ADS)
Arpaia, Pasquale; Buzio, Marco; Golluccio, Giancarlo; Walckiers, Louis
2012-08-01
A method to characterize permanent and fast-pulsed iron-dominated magnets with small apertures is presented. The harmonic coil measurement technique is enhanced specifically for small-aperture magnets by (1) in situ calibration, for facing search-coil production inaccuracy, (2) rotating the magnet around its axis, for correcting systematic effects, and (3) measuring magnetic fluxes by stationary coils at different angular positions for measuring fast pulsed magnets. This method allows a quadrupole magnet for particle accelerators to be characterized completely, by assessing multipole field components, magnetic axis position, and field direction. In this paper, initially the metrological problems arising from testing small-aperture magnets are highlighted. Then, the basic ideas of the proposed method and the architecture of the corresponding measurement system are illustrated. Finally, experimental validation results are shown for small-aperture permanent and fast-ramped quadrupole magnets for the new linear accelerator Linac4 at CERN (European Organization for Nuclear Research).
NASA Astrophysics Data System (ADS)
Richter, C.; Jensen, S. R.; Acton, G. D.; Evans, H. F.
2017-12-01
We present new paleomagnetic results from Quaternary sediment samples recovered during the Baffin Bay Scientific Coring Expedition conducted by the JOIDES Resolution in 2012. The expedition recovered well-preserved core material from the Arctic Basin, providing an outstanding opportunity for the study of the behavior of the geomagnetic field at high latitude. We analyzed material from 12 sites cored at latitudes between 74°45.32'N and 75°46.68'N in the Melville Bay region (Cape York and Melville Ridge) of Baffin Bay located at an average water depth of 394 m. The Quaternary glaciomarine sediments are up to 150 m thick and consist of very soft diatom-bearing muds to clast-rich sandy and muddy diamicts, which suggest deposition in a subglacial to ice-procimal environment. We carried out paleomagnetic and rock magnetic measurements on the shipboard cryogenic magnetometer at 5-cm resolution on 32 split-core sections and a selected number of discrete samples, and recently processed measurements taken at 1-cm resolution on eight U-channel samples from the uppermost Holocene part of the section. Stepwise demagnetization of the NRM demonstrates excellent demagnetization behavior, with a viscous isothermal remanent magnetization overprint, induced by the coring and sampling process, and typically removed by the 20 mT demagnetization step. The magnetic inclination data are characterized by steep, 80°, normal inclinations, consistent with the site position near the North Pole. Thermal demagnetization, magnetic susceptibility, isothermal remanent magnetization, and hysteresis parameters indicate that the primary magnetic carrier consists of a low-coercivity mineral, e.g., magnetite and/or titanomagnetite, with minor traces of higher-coercivity minerals. Well-developed geomagnetic excursions in the upper part of the section can be correlated between several sites. Although dating of these sediments remains a challenge because of the lack of carbonates we will discuss possible age models and use them to assign ages to the geomagnetic excursions.
Callaghan, Martina F; Freund, Patrick; Draganski, Bogdan; Anderson, Elaine; Cappelletti, Marinella; Chowdhury, Rumana; Diedrichsen, Joern; Fitzgerald, Thomas H B; Smittenaar, Peter; Helms, Gunther; Lutti, Antoine; Weiskopf, Nikolaus
2014-08-01
A pressing need exists to disentangle age-related changes from pathologic neurodegeneration. This study aims to characterize the spatial pattern and age-related differences of biologically relevant measures in vivo over the course of normal aging. Quantitative multiparameter maps that provide neuroimaging biomarkers for myelination and iron levels, parameters sensitive to aging, were acquired from 138 healthy volunteers (age range: 19-75 years). Whole-brain voxel-wise analysis revealed a global pattern of age-related degeneration. Significant demyelination occurred principally in the white matter. The observed age-related differences in myelination were anatomically specific. In line with invasive histologic reports, higher age-related differences were seen in the genu of the corpus callosum than the splenium. Iron levels were significantly increased in the basal ganglia, red nucleus, and extensive cortical regions but decreased along the superior occipitofrontal fascicle and optic radiation. This whole-brain pattern of age-associated microstructural differences in the asymptomatic population provides insight into the neurobiology of aging. The results help build a quantitative baseline from which to examine and draw a dividing line between healthy aging and pathologic neurodegeneration. Copyright © 2014 The Authors. Published by Elsevier Inc. All rights reserved.
Callaghan, Martina F.; Freund, Patrick; Draganski, Bogdan; Anderson, Elaine; Cappelletti, Marinella; Chowdhury, Rumana; Diedrichsen, Joern; FitzGerald, Thomas H.B.; Smittenaar, Peter; Helms, Gunther; Lutti, Antoine; Weiskopf, Nikolaus
2014-01-01
A pressing need exists to disentangle age-related changes from pathologic neurodegeneration. This study aims to characterize the spatial pattern and age-related differences of biologically relevant measures in vivo over the course of normal aging. Quantitative multiparameter maps that provide neuroimaging biomarkers for myelination and iron levels, parameters sensitive to aging, were acquired from 138 healthy volunteers (age range: 19–75 years). Whole-brain voxel-wise analysis revealed a global pattern of age-related degeneration. Significant demyelination occurred principally in the white matter. The observed age-related differences in myelination were anatomically specific. In line with invasive histologic reports, higher age-related differences were seen in the genu of the corpus callosum than the splenium. Iron levels were significantly increased in the basal ganglia, red nucleus, and extensive cortical regions but decreased along the superior occipitofrontal fascicle and optic radiation. This whole-brain pattern of age-associated microstructural differences in the asymptomatic population provides insight into the neurobiology of aging. The results help build a quantitative baseline from which to examine and draw a dividing line between healthy aging and pathologic neurodegeneration. PMID:24656835
NASA Astrophysics Data System (ADS)
Zana, Iulica
In this dissertation the structural and magnetic characterization of high anisotropy Co-rich alloys for magnetic recording and MEMS applications has been carried out. The potential of Co78Sm22 as an ultra-high density recording medium was explored through comprehensive static and dynamic magnetic measurements. It was found out that hard magnetic properties (Hc = 4.5 kOe) can be achieved when CoSm is sputter-deposited on Cr80V 20 underlayer, comparable with those reported for state-of-the-art media at the end of 2002. Furthermore, the chemical stability and reliability of CoSm thin films was studied through combined accelerated aging and electrochemical methods. It was found out that CoSm thin films are more reactive than current recording media (CoPt), and a layer of Si3N4 of at least 6 nm provides satisfactory protection. Electrodeposition of Co80Pt20 onto highly textured Cu seed layer with either {100} or {111} orientation was studied. The influence of Cu texture and plating current density (cd) on the growth, morphology, microstructure, and magnetic properties of the CoPt films was investigated. Epitaxial CoPt thin films with uniform composition across the film thickness were deposited. The microstructure consists in fcc matrix and hcp matrix when plated on Cu(100) and Cu(111), respectively. CoPt hcp single phase films with c-axis normal to the substrate were grown on Cu(111) when plated at cd = 50 mA/cm2. As opposed to the films plated on Cu(100) which show a mostly in-plane magnetic anisotropy, the films plated on Cu(111) develop a well defined perpendicular magnetic anisotropy (PMA) due to the hcp phase with the c-axis normal to the substrate, which yields coercivities as high as 6.1 kOe. The origin of the high PMA was found to lie in the magnetocrystalline anisotropy. CoPt micromagnets have been successfully fabricated by the electrodeposition-through-mask method, which despite the small aspect ratio show a definite PMA. The PMA, together with the hard magnetic properties measured (Hc = 4.7 kOe) demonstrate a strong potential for the utilization of these materials in the MEMS area.
Unique topological characterization of braided magnetic fields
DOE Office of Scientific and Technical Information (OSTI.GOV)
Yeates, A. R.; Hornig, G.
We introduce a topological flux function to quantify the topology of magnetic braids: non-zero, line-tied magnetic fields whose field lines all connect between two boundaries. This scalar function is an ideal invariant defined on a cross-section of the magnetic field, and measures the average poloidal magnetic flux around any given field line, or the average pairwise crossing number between a given field line and all others. Moreover, its integral over the cross-section yields the relative magnetic helicity. Using the fact that the flux function is also an action in the Hamiltonian formulation of the field line equations, we prove thatmore » it uniquely characterizes the field line mapping and hence the magnetic topology.« less
Eddy current characterization of magnetic treatment of nickel 200
NASA Technical Reports Server (NTRS)
Chern, E. J.
1993-01-01
Eddy current methods have been applied to characterize the effect of magnetic treatments on component service-life extension. Coil impedance measurements were acquired and analyzed on nickel 200 specimens that have been subjected to many mechanical and magnetic engineering processes: annealing, applied strain, magnetic field, shot peening, and magnetic field after peening. Experimental results have demonstrated a functional relationship between coil impedance, resistance and reactance, and specimens subjected to various engineering processes. It has shown that magnetic treatment does induce changes in electromagnetic properties of nickel 200 that then exhibit evidence of stress relief. However, further fundamental studies are necessary for a thorough understanding of the exact mechanism of the magnetic field processing effect on machine-tool service life.
NASA Astrophysics Data System (ADS)
Vegas, Néstor; Aranguren, Aitor; Rodríguez-Méndez, Lidia; Cuevas, Julia; María Tubía, José; Julián Esteban, José
2017-04-01
The Mesozoic Basque-Cantabrian basin (western Pyrenees) was inverted during the Alpine Orogeny in late Cretaceous-Eocene times. The central sector of the basin, the Basque Arc is characterized by the existence of large folds (80 km long) that outline an arc. This study focuses on the interpretation of AMS fabrics in rocks from the Biscay Synclinorium, a major fold system of the Basque Arc that verges to the NE, with sub-horizontal, N110˚ E trending axes and axial planes striking to N110˚ E and dipping steeply to the SW (Calvo-Rathert et al., 2007). The aim of this contribution is characterize the deformation around the Biscay Synclinorium. For this reason we combined fieldwork with magnetic fabric analysis of 95 cores in Upper Cretaceous sedimentary rocks of the Biscay Synclinorium. 68 cores come from the Calcareous formation (marls, sandy limestones and limestones of Cenomanian to Campanian age) that makes part of the northeastern limb of the synclinorium and the remaining 27 cores from the Detrital-calcareous flysch (a multilayer sequence with sandy limestones and marls of Maastrichtian age) that crops out in the synclinorium core (Garrote et al., 1991). In the Upper Cretaceous Calcareous formation there is a penetrative cleavage that mainly strikes to N110˚ E dipping 50˚ to 60˚ to the SW (S1). In the Detrital-calcareous flysch of the core, the best-preserved planar structure is the bedding and only locally an axial planar cleavage is observed. Intersection lineations are sub-horizontal and N110˚ E-trending. The measurements of the magnetic susceptibility provide low k values ranging between 99x10-6 and 403x10-6 SI. The anisotropy of the magnetic susceptibility, P, reaches values of 1.213, pointing to the overprinting of tectonic deformation on primary magnetic fabrics of sedimentary origin. The magnetic foliation shows a fairly uniform arrangement that is nearly coincident with the dominant planar structures of the rocks, S0 or S1in the core and the limb of the synclinorium respectively. The magnetic lineation, instead, yields complex patterns, as evidenced by the finding of two main sets of magnetic lineations: 1) weakly plunging N110˚ E-trending lineations; 2) steeply plunging N200˚ E-trending lineations. In both cases the magnetic fabric reflects a tectonic origin but with different geological meaning. The first set, dominant in the core of the synclinorium, is characterised by magnetic lineations parallel to the intersection lineation between S0 and S1. In contrast, the other set come from sites located along the limb of the synclinorium, where lower deformation would be expected. However, owing to the steep plunging of the magnetic lineation and to fact that the highest P values are obtained along this limb, we consider that the second set of magnetic fabrics reflects the existence of a major shear zone at the regional scale, with a top-to-the-NE motion, that has remained unknown until now. Calvo-Rathert, M., Cuevas, J., Tubía, J.M. et al. Int J Earth Sci (Geol Rundsch) (2007) 96: 1163. doi:10.1007/s00531-006-0149-8 Garrote, A., García, J., Fernández, J., Cerezo, A., Tijero, F. and Zapata, M. (1991). Memoria Hoja n° 63-III (Eibar), 1:25.000. Ente Vasco de la Energía-EVE. , pp. 1-50
Experimental insight into the magnetic and electrical properties of amorphous Ge1-xMnx
NASA Astrophysics Data System (ADS)
Conta, Gianluca; Amato, Giampiero; Coïsson, Marco; Tiberto, Paola
2017-12-01
We present a study of the electrical and magnetic properties of the amorphous Ge1-xMnx.DMS, with 2% ≤ x ≤ 17%, by means of SQUID magnetometry and low temperature DC measurements. The thin films were grown by physical vapour deposition at 50°C in ultrahigh vacuum. The DC electrical characterizations show that variable range hopping is the main mechanism of charge transport below room temperature. Magnetic characterization reveals that a unique and smooth magnetic transition is present in our samples, which can be attributed to ferromagnetic percolation of bound magnetic polarons.
Geomagnetic excursions in the Brunhes and Matuyama Chrons: Do they come in bunches?
NASA Astrophysics Data System (ADS)
Channell, J. E. T.
2012-04-01
Geomagnetic excursions, defined here as brief directional aberrations of the main dipole field outside the range of expected secular variation, remain controversial. Poorly-correlated records of apparent excursions from lavas and sediments can often be assigned to sampling artifacts, sedimentological phenomena, volcanic terrane effects, or local secular variation, rather than behavior of the main dipole field. Although records of magnetic excursions date from the 1960s, the number of Brunhes excursions in recent reviews of the subject have reached the 12-17 range, of which only about ~7 are adequately and/or consistently recorded. For the Matuyama Chron, the current inventory of excursions stands at about 10. The better quality excursion records, with reasonable age control, imply millennial-scale or even sub-millennial-scale durations. When "adequately" recorded, excursions are manifest as paired polarity reversals flanking virtual geomagnetic poles (VGPs) that reach high latitudes in the opposite hemisphere. At the young end of the excursion record, the Mono Lake (~33 ka) and Laschamp (~41 ka) excursions are well documented, although records of the former are not widely distributed. Several excursions younger than the Mono Lake excursion (at 17 ka and 25 ka) have recently been recorded in lavas and sediments, respectively. Is the 17-41 ka interval characterized by multiple excursions? Similarly, multiple excursions have been recorded in the 188-238 ka interval that encompasses records of the Iceland Basin excursion (~188 ka) and the Pringle Falls (PF) excursion. The PF excursion has been assigned ages in the 211-238 ka range. Does this mean that this interval is also characterized by several discrete excursions? The 500-600 ka interval incorporates not only the Big Lost excursion at ~565 ka, but also anomalous magnetization directions from lava flows, particularly in the West Eifel volcanics that yield mid-latitude northern-hemisphere VGPs with a range of Ar/Ar ages. The key question is whether such intervals of mid-latitude VGPs denote high-amplitude secular variation or inadequately recorded magnetic excursions. We propose that excursions characterized by high VGP latitudes in the opposite hemisphere should be termed Category 1 excursions, and those manifest by low/mid-latitude VGPs should be termed Category 2 excursions. In the future, improved records may "elevate" Category 2 excursions to Category 1. We do not view this subdivision of Category 1 and Category 2 excursions as necessarily a geomagnetic distinction, but possibly a distinction based on recording fidelity.
Magnetic Anomalies Within Lunar Impact Basins: Constraints on the History of the Lunar Dynamo
NASA Astrophysics Data System (ADS)
Richmond, N. C.; Hood, L. L.
2011-12-01
Previous work has shown that lunar crustal magnetization has a combination of origins including shock remanent magnetization in transient magnetic fields and thermoremanent magnetization in a steady core dynamo magnetic field (e.g., Hood and Artemieva, Icarus, 2008; Richmond and Hood, JGR, 2008; Garrick-Bethell et al., Science, 2009; Hood, Icarus, 2011). In particular, magnetic anomalies within the interiors of lunar impact basins and large craters provide a potentially valuable means of constraining the history of the former dynamo (Halekas et al., MAPS, 2003; Hood, 2011). These anomalies likely have a thermoremanent origin owing to high subsurface temperatures reached at the time of impact and therefore require a long-lived, steady magnetic field to explain their magnetization. Central anomalies have previously been confirmed to be present using Lunar Prospector magnetometer (LP MAG) data within several Nectarian-aged basins (Moscoviense, Mendel-Rydberg, Crisium, and Humboldtianum), implying that a dynamo existed during this lunar epoch (Hood, 2011). Here, we further analyze low altitude LP MAG data for several additional basins, ranging in age from Nectarian to Imbrian. Results indicate that magnetic anomalies with a probable basin-related origin are present within at least two additional Nectarian-aged basins (Serenitatis and Humorum) and one Imbrian-aged basin (Schrodinger). No discernible anomalies are present within the largest Imbrian-aged basins, Imbrium and Orientale. While there is uncertainty regarding the age of the Schrodinger basin, it has been reported to be slightly more recent than Imbrium (Wilhelms, 1984). Our initial interpretation is therefore that a dynamo likely existed during the Imbrian epoch. The absence of anomalies within Imbrium and Orientale can be explained by insufficient conditions for acquisition of strong magnetization (e.g., inadequate concentrations of efficient remanence carriers) following these relatively large impacts.
Functional connectivity in the developing brain: A longitudinal study from 4 to 9 months of age
Damaraju, E.; Caprihan, A.; Lowe, J.R.; Allen, E.A.; Calhoun, V.D.; Phillips, J.P.
2013-01-01
We characterize the development of intrinsic connectivity networks (ICNs) from 4 to 9 months of age with resting state magnetic resonance imaging performed on sleeping infants without sedative medication. Data is analyzed with independent component analysis (ICA). Using both low (30 components) and high (100 components) ICA model order decompositions, we find that the functional network connectivity (FNC) map is largely similar at both 4 and 9 months. However at 9 months the connectivity strength decreases within local networks and increases between more distant networks. The connectivity within the default-mode network, which contains both local and more distant nodes, also increases in strength with age. The low frequency power spectrum increases with age only in the posterior cingulate cortex and posterior default mode network. These findings are consistent with a general developmental pattern of increasing longer distance functional connectivity over the first year of life and raise questions regarding the developmental importance of the posterior cingulate at this age. PMID:23994454
Functional connectivity in the developing brain: a longitudinal study from 4 to 9months of age.
Damaraju, E; Caprihan, A; Lowe, J R; Allen, E A; Calhoun, V D; Phillips, J P
2014-01-01
We characterize the development of intrinsic connectivity networks (ICNs) from 4 to 9months of age with resting state magnetic resonance imaging performed on sleeping infants without sedative medication. Data is analyzed with independent component analysis (ICA). Using both low (30 components) and high (100 components) ICA model order decompositions, we find that the functional network connectivity (FNC) map is largely similar at both 4 and 9months. However at 9months the connectivity strength decreases within local networks and increases between more distant networks. The connectivity within the default-mode network, which contains both local and more distant nodes, also increases in strength with age. The low frequency power spectrum increases with age only in the posterior cingulate cortex and posterior default mode network. These findings are consistent with a general developmental pattern of increasing longer distance functional connectivity over the first year of life and raise questions regarding the developmental importance of the posterior cingulate at this age. © 2013.
Thermal aging of melt-spun NdFeB magnetic powder in hydrogen
NASA Astrophysics Data System (ADS)
Pinkerton, Frederick E.; Balogh, Michael P.; Ellison, Nicole; Foto, Aldo; Sechan, Martin; Tessema, Misle M.; Thompson, Margarita P.
2016-11-01
High energy product neodymium-iron-boron (NdFeB) magnets are the premier candidate for demanding electrified vehicle traction motor applications. Injection molded (IM) or compression molded (CM) magnets made using NdFeB powders are promising routes to improve motor efficiency, cost, and manufacturability. However, IM and CM NdFeB magnets are susceptible to substantial thermal aging losses at motor operating temperatures when exposed to the automatic transmission fluid (ATF) used as a lubricant and cooling medium. The intrinsic coercivity Hci of NdFeB IM and CM magnets degrades by as much as 18% when aged for 1000 h in ATF at 150 °C, compared to a 3% loss when aged in air. Here we report aging studies of rapidly quenched NdFeB powder in air, ATF, and H2 gas. Expansion of the NdFeB crystal lattice in both ATF and H2 identified hydrogen dissociated from the ATF during aging and diffused into the primary NdFeB phase as the probable cause of the coercivity loss of IM and CM magnets.
Wang, Aiyong; Wang, Yilin; Walter, Eric D.; ...
2017-10-07
Cu, Fe and Cu + Fe ion exchanged Beta and SSZ-13 catalysts were prepared by solution ion exchange using commercial NH 4/Beta, and NH 4/SSZ-13 that was prepared in-house. To study hydrothermal aging effects, Beta supported catalysts were aged hydrothermally at 700 °C and SSZ-13 supported catalysts were aged at 750 °C. In order to reveal the effects of Fe addition in the co-exchanged catalysts, these catalysts were characterized by means of powder X-ray diffraction (XRD), N 2 adsorption-desorption, electron paramagnetic resonance (EPR), 27Al-nuclear magnetic resonance ( 27Al-NMR) and propylene coking followed with temperature programmed reaction (TPR), and further testedmore » with standard NH 3-SCR with and without the presence of propylene. Collectively, the catalyst characterizations and reaction testing indicated minor beneficial effects of Fe addition in Cu,Fe/Beta, where NH 3-SCR activity, N 2 selectivity and hydrothermal stability were all slightly improved. In contrast, Fe addition did not show apparent beneficial effects in low-temperature SCR for the Cu,Fe/SSZ-13 case. In conclusion, at elevated reaction temperatures, however, the presence of Fe indeed considerably improved NO conversion and N 2 selectivity for the hydrothermally aged Cu,Fe/SSZ-13 catalyst in the presence of propylene.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Wang, Aiyong; Wang, Yilin; Walter, Eric D.
Cu, Fe and Cu + Fe ion exchanged Beta and SSZ-13 catalysts were prepared by solution ion exchange using commercial NH 4/Beta, and NH 4/SSZ-13 that was prepared in-house. To study hydrothermal aging effects, Beta supported catalysts were aged hydrothermally at 700 °C and SSZ-13 supported catalysts were aged at 750 °C. In order to reveal the effects of Fe addition in the co-exchanged catalysts, these catalysts were characterized by means of powder X-ray diffraction (XRD), N 2 adsorption-desorption, electron paramagnetic resonance (EPR), 27Al-nuclear magnetic resonance ( 27Al-NMR) and propylene coking followed with temperature programmed reaction (TPR), and further testedmore » with standard NH 3-SCR with and without the presence of propylene. Collectively, the catalyst characterizations and reaction testing indicated minor beneficial effects of Fe addition in Cu,Fe/Beta, where NH 3-SCR activity, N 2 selectivity and hydrothermal stability were all slightly improved. In contrast, Fe addition did not show apparent beneficial effects in low-temperature SCR for the Cu,Fe/SSZ-13 case. In conclusion, at elevated reaction temperatures, however, the presence of Fe indeed considerably improved NO conversion and N 2 selectivity for the hydrothermally aged Cu,Fe/SSZ-13 catalyst in the presence of propylene.« less
Scanning microwave microscopy technique for nanoscale characterization of magnetic materials
NASA Astrophysics Data System (ADS)
Joseph, C. H.; Sardi, G. M.; Tuca, S. S.; Gramse, G.; Lucibello, A.; Proietti, E.; Kienberger, F.; Marcelli, R.
2016-12-01
In this work, microwave characterization of magnetic materials using the scanning microwave microscopy (SMM) technique is presented. The capabilities of the SMM are employed for analyzing and imaging local magnetic properties of the materials under test at the nanoscale. The analyses are performed by acquiring both amplitude and phase of the reflected microwave signal. The changes in the reflection coefficient S11 are related to the local properties of the material under investigation, and the changes in its magnetic properties have been studied as a function of an external DC magnetic bias. Yttrium iron garnet (YIG) films deposited by RF sputtering and grown by liquid phase epitaxial (LPE) on gadolinium gallium garnet (GGG) substrates and permalloy samples have been characterized. An equivalent electromagnetic transmission line model is discussed for the quantitative analysis of the local magnetic properties. We also observed the hysteretic behavior of the reflection coefficient S11 with an external bias field. The imaging and spectroscopy analysis on the experimental results are evidently indicating the possibilities of measuring local changes in the intrinsic magnetic properties on the surface of the material.
NASA Astrophysics Data System (ADS)
Liu, Yan; Chen, Linfeng; Tan, C. Y.; Liu, H. J.; Ong, C. K.
2005-06-01
A brief review of the methods used for broadband complex permeability measurement of magnetic thin films up to microwave frequencies is given. In particular, the working principles of the transmission-line perturbation methods for the characterization of magnetic thin films are discussed, with emphasis on short-circuited planar transmission-line perturbation methods. The algorithms for calculating the complex permeability of magnetic thin films for short-circuited planar transmission-line perturbation methods are analyzed. A shorted microstrip line is designed and fabricated as a prototype measurement fixture. The structure of the microstrip fixture and the corresponding measurement procedure are discussed in detail. A piece of 340 nm thick FeTaN thin film deposited on Si substrate using sputtering method is characterized using the microstrip fixture. An improved technique for obtaining permeability by using a saturation magnetization field is demonstrated here, and the results fit well with the Landau-Lifchitz-Gilbert theory. Approaches to extending this method to other aspects in the investigation of magnetic thin film are also discussed.
Magnetic characterization of Daphnia resting eggs.
Sakata, Masanobu; Kawasaki, Tamami; Shibue, Toshimichi; Takada, Atsushi; Yoshimura, Hideyuki; Namiki, Hideo
2006-12-15
This study characterized the magnetic materials found within Daphnia resting eggs by measuring static magnetization with a superconducting quantum interference device (SQUID) magnetometer, after forming two types of conditions, each of which consists of zero-field cooling (ZFC) and field cooling (FC). Magnetic ions, such as Fe(3+), contained in Daphnia resting eggs existed as (1) paramagnetic and superparamagnetic particles, demonstrated by a magnetization and temperature dependence of the magnetic moments under an applied magnetic field after ZFC and FC, and (2) ferromagnetic particles with definite magnetic moments, the content of which was estimated to be very low, demonstrated by the Moskowitz test. Conventionally, biomagnets have been directly detected by transmission electron microscopes (TEM). As demonstrated in this study, it is possible to nondestructively detect small biomagnets by magnetization measurement, especially after two types of ZFC and FC. This nondestructive method can be applied in detecting biomagnets in complex biological organisms.
A 3D-Printable Polymer-Metal Soft-Magnetic Functional Composite-Development and Characterization.
Khatri, Bilal; Lappe, Karl; Noetzel, Dorit; Pursche, Kilian; Hanemann, Thomas
2018-01-25
In this work, a 3D printed polymer-metal soft-magnetic composite was developed and characterized for its material, structural, and functional properties. The material comprises acrylonitrile butadiene styrene (ABS) as the polymer matrix, with up to 40 vol. % stainless steel micropowder as the filler. The composites were rheologically analyzed and 3D printed into tensile and flexural test specimens using a commercial desktop 3D printer. Mechanical characterization revealed a linearly decreasing trend of the ultimate tensile strength (UTS) and a sharp decrease in Young's modulus with increasing filler content. Four-point bending analysis showed a decrease of up to 70% in the flexural strength of the composite and up to a two-factor increase in the secant modulus of elasticity. Magnetic hysteresis characterization revealed retentivities of up to 15.6 mT and coercive forces of up to 4.31 kA/m at an applied magnetic field of 485 kA/m. The composite shows promise as a material for the additive manufacturing of passive magnetic sensors and/or actuators.
A 3D-Printable Polymer-Metal Soft-Magnetic Functional Composite—Development and Characterization
Lappe, Karl; Noetzel, Dorit; Pursche, Kilian; Hanemann, Thomas
2018-01-01
In this work, a 3D printed polymer–metal soft-magnetic composite was developed and characterized for its material, structural, and functional properties. The material comprises acrylonitrile butadiene styrene (ABS) as the polymer matrix, with up to 40 vol. % stainless steel micropowder as the filler. The composites were rheologically analyzed and 3D printed into tensile and flexural test specimens using a commercial desktop 3D printer. Mechanical characterization revealed a linearly decreasing trend of the ultimate tensile strength (UTS) and a sharp decrease in Young’s modulus with increasing filler content. Four-point bending analysis showed a decrease of up to 70% in the flexural strength of the composite and up to a two-factor increase in the secant modulus of elasticity. Magnetic hysteresis characterization revealed retentivities of up to 15.6 mT and coercive forces of up to 4.31 kA/m at an applied magnetic field of 485 kA/m. The composite shows promise as a material for the additive manufacturing of passive magnetic sensors and/or actuators. PMID:29370112
NASA Astrophysics Data System (ADS)
Wiszniewska, Janina; Petecki, Zdzislaw; Rosowiecka, Olga; Krzemińska, Ewa
2017-04-01
Suwałki Anorthosite Massif (SAM) is located within 200 km long Mesoproterozoic magmatic terrane called Mazury Complex (NE Poland) (Wiszniewska et al. 2002). This is a belt of granitoids and associated mafic and intermediate igneous rocks followed an E-W trending lineament extending from the Baltic Sea through northern Poland and southern Lithuania to western Belarus. Crystalline basement of the Suwałki region is covered by a thick pile (550-1300m) of Phanerozoic sedimentary rocks, which are dipping towards the SW East European Craton`s border. SAM is a complex structure composed primarily of magmatic massif type anorthosites, surrounded by a rim of norite-gabbronorite and diorite rocks. SAM is characterized by magnetic and gravimetric negative anomalies. The gravimetric one is related to anorthosite massif. It is surrounded by a few positive anomalies, which reflect occurrences of denser rocks such as granite, monzodiorite and granodiorite. The large magnetic anomaly is supposed to reflect an effect of an negative inclination of remanent magnetization of anorthosite rocks. This hypothesis was confirmed by magnetic modelling along DSS POLONAISE'97 profile P4 (Petecki, 2006). Existing measurements however do not show prevailing negative inclinations, even though they prove very high remanent magnetization of anorthosites. A pronounced residual magnetic anomalies of Udryń and Krzemianka are related to Fe-Ti-(V) ore deposits recognized by deep boreholes. Based on potential field data it was suggested that anorthosite bottom reaches 2,5-4,5 km depth. Thus it is evident that the geological architecture of SAM and its surrounding area is not fully recognized. The problem is supposed to be resolved using modern methods of geophysical transformations and 3D modelling using GeoModeller software. The final result of the research will be to recognize spatial structure of the SAM and its surrounding. Petrological, mineralogical, geochronological (U-Pb SHRIMP method on zircons and titanite) and tectonic testing from SAM were carried out. Structural analysis were also performed on a basis of the identified tectonic structures on selected cores. Recognition of possible connections of tectonic structures with magmatic processes and pegmatite, aplite, quartz veins including their mineral composition have been checked. For pegmatite, aplite, hydrothermal and quartz veins age determinations, U-Pb SHRIMP IIe method on zircon, monazite and titanite have been done. The primary age measurements of zircons from microgranite veins within anorthosite have shown consistent Paleoproterozoic ages of protolith ( 1844±11 Ma for Krzemianka 73) with Mezoproterozoic ages ( 1.5 Ga) of metamorphic rims, similar to monazite ages ( 1469±16 Ma). The microgranite veins are probably derived from the older Paleoproterozoic crust, carrying a relic zircons of 1.84 Ga ages but also some inherited older ages as 2.0 to 2.3 Ga. The future planned works will concern the genesis and evolution of igneous AMCG rocks suite and related ore mineralization of the SAM. Petecki Z., 2006: Integrated gravity and magnetic modelling along P4 seismic profile (in Polish). Pr. Państw. Inst. Geol. CLXI., 193p. Wiszniewska J., Claesson S., Stein H., Vander Auwera J., Duchense J-C., 2002: The north-eastern Polish anorthosite massifs: petrological, geochemical and isotopic evidence for a crustal derivation. Terra Nova 14, p.451-460 This is a contribution to the project " Determination of architecture and geological evolution of the Suwałki Anothosite Massif by 3D geological and geophysical data modelling method" NCN grant 51.2115.1601.09.0
Versatile magnetometer assembly for characterizing magnetic properties of nanoparticles.
Araujo, J F D F; Bruno, A C; Louro, S R W
2015-10-01
We constructed a versatile magnetometer assembly for characterizing iron oxide nanoparticles. The magnetometer can be operated at room temperature or inside a cryocooler at temperatures as low as 6 K. The magnetometer's sensor can be easily exchanged and different detection electronics can be used. We tested the assembly with a non-cryogenic commercial Hall sensor and a benchtop multimeter in a four-wire resistance measurement scheme. A magnetic moment sensitivity of 8.5 × 10(-8) Am(2) was obtained with this configuration. To illustrate the capability of the assembly, we synthesized iron oxide nanoparticles coated with different amounts of a triblock copolymer, Pluronic F-127, and characterized their magnetic properties. We determined that the polymer coating does not affect the magnetization of the particles at room temperature and demonstrates that it is possible to estimate the average size of coating layers from measurements of the magnetic field of the sample.
Versatile magnetometer assembly for characterizing magnetic properties of nanoparticles
NASA Astrophysics Data System (ADS)
Araujo, J. F. D. F.; Bruno, A. C.; Louro, S. R. W.
2015-10-01
We constructed a versatile magnetometer assembly for characterizing iron oxide nanoparticles. The magnetometer can be operated at room temperature or inside a cryocooler at temperatures as low as 6 K. The magnetometer's sensor can be easily exchanged and different detection electronics can be used. We tested the assembly with a non-cryogenic commercial Hall sensor and a benchtop multimeter in a four-wire resistance measurement scheme. A magnetic moment sensitivity of 8.5 × 10-8 Am2 was obtained with this configuration. To illustrate the capability of the assembly, we synthesized iron oxide nanoparticles coated with different amounts of a triblock copolymer, Pluronic F-127, and characterized their magnetic properties. We determined that the polymer coating does not affect the magnetization of the particles at room temperature and demonstrates that it is possible to estimate the average size of coating layers from measurements of the magnetic field of the sample.
Genetic and Diagnostic Biomarker Development in ASD Toddlers Using Resting State Functional MRI
2015-09-01
connectivity networks during natural sleep as a neurologic biomarker for ASD that is suitable for diagnostic use in young children (ages 1-4). Existing... Autism Spectrum Disorders (ASD); functional magnetic resonance imaging (fMRI); connectivity modeling 16. SECURITY CLASSIFICATION OF: 17. LIMITATION...Requirements………………………………….. 4 9. Appendices…………………………………………………………….. 4 1. INTRODUCTION Autism spectrum disorders (ASD), characterized by abnormal
Magnetic resonance imaging of the pediatric brain
DOE Office of Scientific and Technical Information (OSTI.GOV)
Salamon, G.; Raynaud, C.; Regis, J.
1990-01-01
The atlas presents sequences of MRI sections parallel to the orbito-meatal plane in children from birth through the age of sixteen years. Each child was studied horizontally and sagitally and three-dimensional brain images were reconstructed to facilitate accurate identification of sulci and gyri. The images show crucial aspects of brain development such as the constancy of the brain stem and primitive brain from birth onward; the development of the telencephalon, characterized by deepening of sulci and growth of the cerebral cortex surface; and the different stages of white matter myelinization.
White matter hyperintensities and normal-appearing white matter integrity in the aging brain.
Maniega, Susana Muñoz; Valdés Hernández, Maria C; Clayden, Jonathan D; Royle, Natalie A; Murray, Catherine; Morris, Zoe; Aribisala, Benjamin S; Gow, Alan J; Starr, John M; Bastin, Mark E; Deary, Ian J; Wardlaw, Joanna M
2015-02-01
White matter hyperintensities (WMH) of presumed vascular origin are a common finding in brain magnetic resonance imaging of older individuals and contribute to cognitive and functional decline. It is unknown how WMH form, although white matter degeneration is characterized pathologically by demyelination, axonal loss, and rarefaction, often attributed to ischemia. Changes within normal-appearing white matter (NAWM) in subjects with WMH have also been reported but have not yet been fully characterized. Here, we describe the in vivo imaging signatures of both NAWM and WMH in a large group of community-dwelling older people of similar age using biomarkers derived from magnetic resonance imaging that collectively reflect white matter integrity, myelination, and brain water content. Fractional anisotropy (FA) and magnetization transfer ratio (MTR) were significantly lower, whereas mean diffusivity (MD) and longitudinal relaxation time (T1) were significantly higher, in WMH than NAWM (p < 0.0001), with MD providing the largest difference between NAWM and WMH. Receiver operating characteristic analysis on each biomarker showed that MD differentiated best between NAWM and WMH, identifying 94.6% of the lesions using a threshold of 0.747 × 10(-9) m(2)s(-1) (area under curve, 0.982; 95% CI, 0.975-0.989). Furthermore, the level of deterioration of NAWM was strongly associated with the severity of WMH, with MD and T1 increasing and FA and MTR decreasing in NAWM with increasing WMH score, a relationship that was sustained regardless of distance from the WMH. These multimodal imaging data indicate that WMH have reduced structural integrity compared with surrounding NAWM, and MD provides the best discriminator between the 2 tissue classes even within the mild range of WMH severity, whereas FA, MTR, and T1 only start reflecting significant changes in tissue microstructure as WMH become more severe. Copyright © 2015 The Authors. Published by Elsevier Inc. All rights reserved.
Stirling Technology Development at NASA GRC. Revised
NASA Technical Reports Server (NTRS)
Thieme, Lanny G.; Schreiber, Jeffrey G.; Mason, Lee S.
2002-01-01
The Department of Energy, Stirling Technology Company (STC), and NASA Glenn Research Center (NASA Glenn) are developing a free-piston Stirling convertor for a high-efficiency Stirling Radioisotope Generator (SRG) for NASA Space Science missions. The SRG is being developed for multimission use, including providing electric power for unmanned Mars rovers and deep space missions. NASA Glenn is conducting an in-house technology project to assist in developing the convertor for space qualification and mission implementation. Recent testing, of 55-We Technology Demonstration Convertors (TDC's) built by STC includes mapping, of a second pair of TDC's, single TDC testing, and TDC electromagnetic interference and electromagnetic compatibility characterization on a nonmagnetic test stand. Launch environment tests of a single TDC without its pressure vessel to better understand the convertor internal structural dynamics and of dual-opposed TDC's with several engineering mounting structures with different natural frequencies have recently been completed. A preliminary life assessment has been completed for the TDC heater head, and creep testing of the IN718 material to be used for the flight convertors is underway. Long-term magnet aging tests are continuing to characterize any potential aging in the strength or demagnetization resistance of the magnets used in the linear alternator (LA). Evaluations are now beginning on key organic materials used in the LA and piston/rod surface coatings. NASA Glenn is also conducting finite element analyses for the LA, in part to look at the demagnetization margin on the permanent magnets. The world's first known integrated test of a dynamic power system with electric propulsion was achieved at NASA Glenn when a Hall-effect thruster was successfully operated with a free-piston Stirling power source. Cleveland State University is developing a multidimensional Stirling computational fluid dynamics code to significantly improve Stirling loss predictions and assist in identifying convertor areas for further improvements. This paper will update the status and results for these efforts.
Stirling Technology Development at NASA GRC
NASA Technical Reports Server (NTRS)
Thieme, Lanny G.; Schreiber, Jeffrey G.; Mason, Lee S.
2001-01-01
The Department of Energy, Stirling Technology Company (STC), and NASA Glenn Research Center (NASA Glenn) are developing a free-piston Stirling convertor for a high efficiency Stirling Radioisotope Generator (SRG) for NASA Space Science missions. The SRG is being developed for multimission use, including providing electric power for unmanned Mars rovers and deep space missions. NASA Glenn is conducting an in-house technology project to assist in developing the convertor for space qualification and mission implementation. Recent testing of 55-We Technology Demonstration Convertors (TDCs) built by STC includes mapping of a second pair of TDCs, single TDC testing, and TDC electromagnetic interference and electromagnetic compatibility characterization on a nonmagnetic test stand. Launch environment tests of a single TDC without its pressure vessel to better understand the convertor internal structural dynamics and of dual-opposed TDCs with several engineering mounting structures with different natural frequencies have recently been completed. A preliminary life assessment has been completed for the TDC heater head, and creep testing of the IN718 material to be used for the flight convertors is underway. Long-term magnet aging tests are continuing to characterize any potential aging in the strength or demagnetization resistance of the magnets used in the linear alternator (LA). Evaluations are now beginning on key organic materials used in the LA and piston/rod surface coatings. NASA Glenn is also conducting finite element analyses for the LA, in part to look at the demagnetization margin on the permanent magnets. The world's first known integrated test of a dynamic power system with electric propulsion was achieved at NASA Glenn when a Hall-effect thruster was successfully operated with a free-piston Stirling power source. Cleveland State University is developing a multidimensional Stirling computational fluid dynamics code to significantly improve Stirling loss predictions and assist in identifying convertor areas for further improvements. This paper will update the status and results for these efforts.
Leung, Jackie; Kosinski, Przemyslaw D; Croal, Paula L; Kassner, Andrea
2016-05-15
Cerebrovascular reactivity (CVR) reflects the vasodilatory reserve of cerebral resistance vessels. Normal development in children is associated with significant changes in blood pressure, cerebral blood flow (CBF) and cerebral oxygen metabolism. Therefore, it stands to reason that CVR will also undergo changes during this period. The study acquired magnetic resonance imaging measures of CVR and CBF in healthy children and young adults to trace their changes with age. We found that CVR changes in two phases, increasing with age until the mid-teens, followed by a decrease. Baseline CBF declined steadily with age. We conclude that CVR varies with age during childhood, which prompts future CVR studies involving children to take into account the effect of development. Cerebrovascular reactivity (CVR) reflects the vasculature's ability to accommodate changes in blood flow demand thereby serving as a critical imaging tool for mapping vascular reserve. Normal development is associated with extensive physiological changes in blood pressure, cerebral blood flow and cerebral metabolic rate of oxygen, all of which can affect CVR. Moreover, the evolution of these physiological parameters is most prominent during childhood. Therefore, the aim of this study was to use non-invasive magnetic resonance imaging (MRI) to characterize the developmental trajectories of CVR in healthy children and young adults, and relate them to changes in cerebral blood flow (CBF). Thirty-four healthy subjects (17 males, 17 females; age 9-30 years) underwent CVR assessment using blood oxygen level-dependent MRI in combination with a computer controlled CO2 stimulus. In addition, baseline CBF was measured with a pulsed arterial spin labelling sequence. CVR exhibited a gradual increase with age in both grey and white matter up to 14.7 years. After this break point, a negative correlation with age was detected. Baseline CBF maintained a consistent negative linear correlation across the entire age range. The significant age-dependent changes in CVR and CBF demonstrate the evolution of cerebral haemodynamics in children and should be taken into consideration. The shift in developmental trajectory of CVR from increasing to decreasing suggests that physiological factors beyond baseline CBF also influence CVR. © 2016 The Authors. The Journal of Physiology © 2016 The Physiological Society.
Zaia, Annamaria
2015-01-01
Osteoporosis represents one major health condition for our growing elderly population. It accounts for severe morbidity and increased mortality in postmenopausal women and it is becoming an emerging health concern even in aging men. Screening of the population at risk for bone degeneration and treatment assessment of osteoporotic patients to prevent bone fragility fractures represent useful tools to improve quality of life in the elderly and to lighten the related socio-economic impact. Bone mineral density (BMD) estimate by means of dual-energy X-ray absorptiometry is normally used in clinical practice for osteoporosis diagnosis. Nevertheless, BMD alone does not represent a good predictor of fracture risk. From a clinical point of view, bone microarchitecture seems to be an intriguing aspect to characterize bone alteration patterns in aging and pathology. The widening into clinical practice of medical imaging techniques and the impressive advances in information technologies together with enhanced capacity of power calculation have promoted proliferation of new methods to assess changes of trabecular bone architecture (TBA) during aging and osteoporosis. Magnetic resonance imaging (MRI) has recently arisen as a useful tool to measure bone structure in vivo. In particular, high-resolution MRI techniques have introduced new perspectives for TBA characterization by non-invasive non-ionizing methods. However, texture analysis methods have not found favor with clinicians as they produce quite a few parameters whose interpretation is difficult. The introduction in biomedical field of paradigms, such as theory of complexity, chaos, and fractals, suggests new approaches and provides innovative tools to develop computerized methods that, by producing a limited number of parameters sensitive to pathology onset and progression, would speed up their application into clinical practice. Complexity of living beings and fractality of several physio-anatomic structures suggest fractal analysis as a promising approach to quantify morpho-functional changes in both aging and pathology. In this particular context, fractal lacunarity seems to be the proper tool to characterize TBA texture as it is able to describe both discontinuity of bone network and sizes of bone marrow spaces, whose changes are an index of bone fracture risk. In this paper, an original method of MRI texture analysis, based on TBA fractal lacunarity is described and discussed in the light of new perspectives for early diagnosis of osteoporotic fractures. PMID:25793162
Shen, Mark D; Nordahl, Christine W; Young, Gregory S; Wootton-Gorges, Sandra L; Lee, Aaron; Liston, Sarah E; Harrington, Kayla R; Ozonoff, Sally; Amaral, David G
2013-09-01
Prospective studies of infants at risk for autism spectrum disorder have provided important clues about the early behavioural symptoms of autism spectrum disorder. Diagnosis of autism spectrum disorder, however, is not currently made until at least 18 months of age. There is substantially less research on potential brain-based differences in the period between 6 and 12 months of age. Our objective in the current study was to use magnetic resonance imaging to identify any consistently observable brain anomalies in 6-9 month old infants who would later develop autism spectrum disorder. We conducted a prospective infant sibling study with longitudinal magnetic resonance imaging scans at three time points (6-9, 12-15, and 18-24 months of age), in conjunction with intensive behavioural assessments. Fifty-five infants (33 'high-risk' infants having an older sibling with autism spectrum disorder and 22 'low-risk' infants having no relatives with autism spectrum disorder) were imaged at 6-9 months; 43 of these (27 high-risk and 16 low-risk) were imaged at 12-15 months; and 42 (26 high-risk and 16 low-risk) were imaged again at 18-24 months. Infants were classified as meeting criteria for autism spectrum disorder, other developmental delays, or typical development at 24 months or later (mean age at outcome: 32.5 months). Compared with the other two groups, infants who developed autism spectrum disorder (n = 10) had significantly greater extra-axial fluid at 6-9 months, which persisted and remained elevated at 12-15 and 18-24 months. Extra-axial fluid is characterized by excessive cerebrospinal fluid in the subarachnoid space, particularly over the frontal lobes. The amount of extra-axial fluid detected as early as 6 months was predictive of more severe autism spectrum disorder symptoms at the time of outcome. Infants who developed autism spectrum disorder also had significantly larger total cerebral volumes at both 12-15 and 18-24 months of age. This is the first magnetic resonance imaging study to prospectively evaluate brain growth trajectories from infancy in children who develop autism spectrum disorder. The presence of excessive extra-axial fluid detected as early as 6 months and the lack of resolution by 24 months is a hitherto unreported brain anomaly in infants who later develop autism spectrum disorder. This is also the first magnetic resonance imaging evidence of brain enlargement in autism before age 2. These findings raise the potential for the use of structural magnetic resonance imaging to aid in the early detection of children at risk for autism spectrum disorder or other neurodevelopmental disorders.
Calvente, Irene; Dávila-Arias, Cristina; Ocón-Hernández, Olga; Pérez-Lobato, Rocío; Ramos, Rosa; Artacho-Cordón, Francisco; Olea, Nicolás; Núñez, María Isabel; Fernández, Mariana F.
2014-01-01
Objective To characterize the exposure to electric fields and magnetic fields of non-ionizing radiation in the electromagnetic spectrum (15 Hz to 100 kHz) in the dwellings of children from the Spanish Environment and Childhood-“INMA” population-based birth cohort. Methodology The study sample was drawn from the INMA-Granada cohort. Out of 300 boys participating in the 9–10 year follow-up, 123 families agreed to the exposure assessment at home and completed a specific ad hoc questionnaire gathering information on sources of non-ionizing radiation electric and magnetic fields inside the homes and on patterns of use. Long-term indoor measurements were carried out in the living room and bedroom. Results Survey data showed a low exposure in the children's homes according to reference levels of the International Commission on Non-Ionizing Radiation Protection but with large differences among homes in mean and maximum values. Daytime electrostatic and magnetic fields were below the quantification limit in 78.6% (92 dwellings) and 92.3% (108 dwellings) of houses, with an arithmetic mean value (± standard deviation) of 7.31±9.32 V/m and 162.30±91.16 nT, respectively. Mean magnetic field values were 1.6 lower during the night than the day. Nocturnal electrostatic values were not measured. Exposure levels were influenced by the area of residence (higher values in urban/semi-urban versus rural areas), type of dwelling, age of dwelling, floor of the dwelling, and season. Conclusion Given the greater sensitivity to extremely low-frequency electromagnetic fields of children and following the precautionary principle, preventive measures are warranted to reduce their exposure. PMID:25192253
Calvente, Irene; Dávila-Arias, Cristina; Ocón-Hernández, Olga; Pérez-Lobato, Rocío; Ramos, Rosa; Artacho-Cordón, Francisco; Olea, Nicolás; Núñez, María Isabel; Fernández, Mariana F
2014-01-01
To characterize the exposure to electric fields and magnetic fields of non-ionizing radiation in the electromagnetic spectrum (15 Hz to 100 kHz) in the dwellings of children from the Spanish Environment and Childhood-"INMA" population-based birth cohort. The study sample was drawn from the INMA-Granada cohort. Out of 300 boys participating in the 9-10 year follow-up, 123 families agreed to the exposure assessment at home and completed a specific ad hoc questionnaire gathering information on sources of non-ionizing radiation electric and magnetic fields inside the homes and on patterns of use. Long-term indoor measurements were carried out in the living room and bedroom. Survey data showed a low exposure in the children's homes according to reference levels of the International Commission on Non-Ionizing Radiation Protection but with large differences among homes in mean and maximum values. Daytime electrostatic and magnetic fields were below the quantification limit in 78.6% (92 dwellings) and 92.3% (108 dwellings) of houses, with an arithmetic mean value (± standard deviation) of 7.31±9.32 V/m and 162.30±91.16 nT, respectively. Mean magnetic field values were 1.6 lower during the night than the day. Nocturnal electrostatic values were not measured. Exposure levels were influenced by the area of residence (higher values in urban/semi-urban versus rural areas), type of dwelling, age of dwelling, floor of the dwelling, and season. Given the greater sensitivity to extremely low-frequency electromagnetic fields of children and following the precautionary principle, preventive measures are warranted to reduce their exposure.
Homozygous TREM2 mutation in a family with atypical frontotemporal dementia.
Le Ber, Isabelle; De Septenville, Anne; Guerreiro, Rita; Bras, José; Camuzat, Agnès; Caroppo, Paola; Lattante, Serena; Couarch, Philippe; Kabashi, Edor; Bouya-Ahmed, Kawtar; Dubois, Bruno; Brice, Alexis
2014-10-01
TREM2 mutations were first identified in Nasu-Hakola disease, a rare autosomal recessive disease characterized by recurrent fractures because of bone cysts and presenile dementia. Recently, homozygous and compound heterozygous TREM2 mutations were identified in rare families with frontotemporal lobar degeneration (FTLD) but without bone involvement. We identified a p.Thr66Met heterozygous mutation in a new consanguineous Italian family. Two sibs had early onset autosomal recessive FTLD without severe bone disorders. Atypical signs were present in this family: early parietal and hippocampus involvement, parkinsonism, epilepsy, and corpus callosum thickness on brain magnetic resonance imaging. This study further demonstrates the implication of TREM2 mutations in FTLD phenotypes. It illustrates the variability of bone phenotype and underlines the frequency of atypical signs in TREM2 carriers. This and previous studies evidence that TREM2 mutation screening should be limited to autosomal recessive FTLD with atypical phenotypes characterized by: (1) a very young age at onset (20-50 years); (2) early parietal and hippocampal deficits; (3) the presence of seizures and parkinsonism; (4) suggestive extensive white matter lesions and corpus callosum thickness on brain magnetic resonance imaging. Copyright © 2014 Elsevier Inc. All rights reserved.
Homozygous TREM2 mutation in a family with atypical frontotemporal dementia
Bras, José; Camuzat, Agnès; Caroppo, Paola; Lattante, Serena; Couarch, Philippe; Kabashi, Edor; Bouya-Ahmed, Kawtar; Dubois, Bruno; Brice, Alexis
2014-01-01
TREM2 mutations were first identified in Nasu-Hakola disease, a rare autosomal recessive disease characterized by recurrent fractures because of bone cysts and presenile dementia. Recently, homozygous and compound heterozygous TREM2 mutations were identified in rare families with frontotemporal lobar degeneration (FTLD) but without bone involvement. We identified a p.Thr66Met heterozygous mutation in a new consanguineous Italian family. Two sibs had early onset autosomal recessive FTLD without severe bone disorders. Atypical signs were present in this family: early parietal and hippocampus involvement, parkinsonism, epilepsy, and corpus callosum thickness on brain magnetic resonance imaging. This study further demonstrates the implication of TREM2 mutations in FTLD phenotypes. It illustrates the variability of bone phenotype and underlines the frequency of atypical signs in TREM2 carriers. This and previous studies evidence that TREM2 mutation screening should be limited to autosomal recessive FTLD with atypical phenotypes characterized by: (1) a very young age at onset (20–50 years); (2) early parietal and hippocampal deficits; (3) the presence of seizures and parkinsonism; (4) suggestive extensive white matter lesions and corpus callosum thickness on brain magnetic resonance imaging. PMID:24910390
Niemöller, Arvid; Jakes, Peter; Eurich, Svitlana; Paulus, Anja; Kungl, Hans; Eichel, Rüdiger-A; Granwehr, Josef
2018-01-07
Despite the multitude of analytical methods available to characterize battery cathode materials, identifying the factors responsible for material aging is still challenging. We present the first investigation of transient redox processes in a spinel cathode during electrochemical cycling of a lithium ion battery by in operando electron paramagnetic resonance (EPR). The battery contains a LiNi 0.5 Mn 1.5 O 4 (LNMO) spinel cathode, which is a material whose magnetic interactions are well understood. The evolution of the EPR signal in combination with electrochemical measurements shows the impact of Mn 3+ on the Li + motion inside the spinel. Moreover, state of charge dependent linewidth variations confirm the formation of a solid solution for slow cycling, which is taken over by mixed models of solid solution and two-phase formation for fast cycling due to kinetic restrictions and overpotentials. Long-term measurements for 480 h showed the stability of the investigated LNMO, but also small amounts of cathode degradation products became visible. The results point out how local, exchange mediated magnetic interactions in cathode materials are linked with battery performance and can be used for material characterization.
NASA Astrophysics Data System (ADS)
Niemöller, Arvid; Jakes, Peter; Eurich, Svitlana; Paulus, Anja; Kungl, Hans; Eichel, Rüdiger-A.; Granwehr, Josef
2018-01-01
Despite the multitude of analytical methods available to characterize battery cathode materials, identifying the factors responsible for material aging is still challenging. We present the first investigation of transient redox processes in a spinel cathode during electrochemical cycling of a lithium ion battery by in operando electron paramagnetic resonance (EPR). The battery contains a LiNi0.5Mn1.5O4 (LNMO) spinel cathode, which is a material whose magnetic interactions are well understood. The evolution of the EPR signal in combination with electrochemical measurements shows the impact of Mn3+ on the Li+ motion inside the spinel. Moreover, state of charge dependent linewidth variations confirm the formation of a solid solution for slow cycling, which is taken over by mixed models of solid solution and two-phase formation for fast cycling due to kinetic restrictions and overpotentials. Long-term measurements for 480 h showed the stability of the investigated LNMO, but also small amounts of cathode degradation products became visible. The results point out how local, exchange mediated magnetic interactions in cathode materials are linked with battery performance and can be used for material characterization.
NASA Astrophysics Data System (ADS)
Bowles, J. A.; Patiman, A.
2017-12-01
The recorded geomagnetic field intensity is a function of magnetic mineralogy, grain size, and mineral concentration as well as material stability in nature and during laboratory experiments. Fresh, unhydrated, volcanic glasses are recognized as a nearly ideal natural material for use in paleointensity experiments because they contain the requisite single domain to pseudo-single-domain magnetic particles. Although alteration of magnetic mineralogy can be monitored during the experiments, it is unclear how mineralogy and hence magnetization might change with age as the metastable glass structure relaxes and/or the glass becomes hydrated. Bulk magnetic properties as a function of age show no clear trend, even over hundreds of millions of years. This may be due to the fact that even in fresh, unhydrated glass, there are small-scale differences in magnetic properties due to variation cooling rate or composition variations. Therefore, in order to better understand how magnetic mineralogy evolves with time and hydration, we conducted artificial aging and hydration experiments on fresh, unhydrated rhyolitic (South Deadman Creek, California, 650-yr) and basaltic (Axial Seamount, 2011) end-member glasses. Here, we present the results of artificial aging and hydration experiments. Elevated temperatures accelerate the glass relaxation process in a way that relaxation time decreases with increasing temperature. Aged samples are dry-annealed at 200, 300 and 400 °C for up to 240 days. A second set of samples are hydrated under pressure at 300°C and 450°C. In all cases, isothermal remanent magnetization (IRM) acquisition is monitored to assess changes in the coercivity spectrum and saturation IRM. Preliminary aging results show that in basaltic and rhyolitic glass there is one main peak coercivity at 150 mT and 35 mT, respectively. An increasing sIRM and decreasing peak coercivity trend is observed in basaltic glass whereas no trend is shown in the rhyolitic glass in both parameters after 60 days for all three temperatures in aging experiment. This could be caused by the coarsening of the existing magnetic grains as the glass structure relaxes during aging. We tentatively conclude that one should be cautious with using older glassy samples in absolute paleointensity experiments.
High magnetic field processing of liquid crystalline polymers
Smith, M.E.; Benicewicz, B.C.; Douglas, E.P.
1998-11-24
A process of forming bulk articles of oriented liquid crystalline thermoset material, the material characterized as having an enhanced tensile modulus parallel to orientation of an applied magnetic field of at least 25 percent greater than said material processed in the absence of a magnetic field, by curing a liquid crystalline thermoset precursor within a high strength magnetic field of greater than about 2 Tesla, is provided, together with a resultant bulk article of a liquid crystalline thermoset material, said material processed in a high strength magnetic field whereby said material is characterized as having a tensile modulus parallel to orientation of said field of at least 25 percent greater than said material processed in the absence of a magnetic field.
High magnetic field processing of liquid crystalline polymers
Smith, Mark E.; Benicewicz, Brian C.; Douglas, Elliot P.
1998-01-01
A process of forming bulk articles of oriented liquid crystalline thermoset material, the material characterized as having an enhanced tensile modulus parallel to orientation of an applied magnetic field of at least 25 percent greater than said material processed in the absence of a magnetic field, by curing a liquid crystalline thermoset precursor within a high strength magnetic field of greater than about 2 Tesla, is provided, together with a resultant bulk article of a liquid crystalline thermoset material, said material processed in a high strength magnetic field whereby said material is characterized as having a tensile modulus parallel to orientation of said field of at least 25 percent greater than said material processed in the absence of a magnetic field.
NASA Astrophysics Data System (ADS)
Makaroglu, O.; Nowaczyk, N. R.; Cagatay, M. N.; Acar, D.; Akcer On, S.; Orbay, N.
2016-12-01
We present the results of high resolution mineral magnetic and geochemical analyses from the 512 cm long Core KCL12P2, recovered from the deepest basin of Küçükçekmece Lagoon (40.98° N, 28.76° E), located north of the Sea of Marmara. According to the age-depth model based on radiocarbon, paleomagnetic and global proxy correlation, the core sedimentary section covers the last 3800 years and consists of three different lithologies, based on lithological variations and down core mineral magnetic composition. Lithology A is composed of grey to brown laminated sediment that is siderite-rich as evidenced by the thermomagnetic analysis. It has low to intermediate Ca and Sr, low Ca/Ti and high Br (organic carbon). This lithology was deposited during relatively humid periods with high organic productivity and high terrigeneous input, which occurred during 3150-1700 a BP, 3600-3350 a and 1500 a BP-present. Lithology B consists of homogeneous black sediments characterized by the predominance of single magnetic domain (SD) and the highest magnetic susceptibility (100-2200x10-6), S-ratios (0.95 - 0.99), HIRM (100-2400) and SIRM/κLF (58-100kAm-1) values producing distinct peaks. The thickness of this lithology varies in thickness between 5 and 10 cm in the core. The thermomagnetic and mineral magnetic parameters indicate the predominance of greigite in lithology B, which occurred during 1500, 3200 and 3600 a BP some decadal periods after each seawater intrusion and establishment of high sulphate concentrations in the lagoon following each dry period represented by lithology C in the sequence. Lithology C is a homogeneous grey mud with low S-ratio, high κLF and high HIRM values indicating an increase in the content of high coercivity magnetic minerals. It is also characterized by high Ca, Sr and Ca/Ti and low Br (low organic carbon). The magnetic and geochemical composition of lithology C indicate that it was deposited during dry periods with low fresh water, nutrient and terrigenous inputs. Such dry periods occurred during 1500-1700 a BP, 3200-3400 a BP and 3600-3800 a BP. Latest archaeological findings with discovery of the water supply canals in the catchment area of the Küçükçekmece Lagoon corresponding to the dry periods support our climate records.
NASA Astrophysics Data System (ADS)
Carpino, Francesca
In the last few decades, the development and use of nanotechnology has become of increasing importance. Magnetic nanoparticles, because of their unique properties, have been employed in many different areas of application. They are generally made of a core of magnetic material coated with some other material to stabilize them and to help disperse them in suspension. The unique feature of magnetic nanoparticles is their response to a magnetic field. They are generally superparamagnetic, in which case they become magnetized only in a magnetic field and lose their magnetization when the field is removed. It is this feature that makes them so useful for drug targeting, hyperthermia and bioseparation. For many of these applications, the synthesis of uniformly sized magnetic nanoparticles is of key importance because their magnetic properties depend strongly on their dimensions. Because of the difficulty of synthesizing monodisperse particulate materials, a technique capable of characterizing the magnetic properties of polydisperse samples is of great importance. Quadrupole magnetic field-flow fractionation (MgFFF) is a technique capable of fractionating magnetic particles based on their content of magnetite or other magnetic material. In MgFFF, the interplay of hydrodynamic and magnetic forces separates the particles as they are carried along a separation channel. Since the magnetic field and the gradient in magnetic field acting on the particles during their migration are known, it is possible to calculate the quantity of magnetic material in the particles according to their time of emergence at the channel outlet. Knowing the magnetic properties of the core material, MgFFF can be used to determine both the size distribution and the mean size of the magnetic cores of polydisperse samples. When magnetic material is distributed throughout the volume of the particles, the derived data corresponds to a distribution in equivalent spherical diameters of magnetic material in the particles. MgFFF is unique in its ability to characterize the distribution in magnetic properties of a particulate sample. This knowledge is not only of importance to the optimization and quality control of particle preparation. It is also of great importance in modeling magnetic cell separation, drug targeting, hyperthermia, and other areas of application.
Brain development and aging: overlapping and unique patterns of change.
Tamnes, Christian K; Walhovd, Kristine B; Dale, Anders M; Østby, Ylva; Grydeland, Håkon; Richardson, George; Westlye, Lars T; Roddey, J Cooper; Hagler, Donald J; Due-Tønnessen, Paulina; Holland, Dominic; Fjell, Anders M
2013-03-01
Early-life development is characterized by dramatic changes, impacting lifespan function more than changes in any other period. Developmental origins of neurocognitive late-life functions are acknowledged, but detailed longitudinal magnetic resonance imaging studies of brain maturation and direct comparisons with aging are lacking. To these aims, a novel method was used to measure longitudinal volume changes in development (n=85, 8-22 years) and aging (n=142, 60-91 years). Developmental reductions exceeded 1% annually in much of the cortex, more than double to that seen in aging, with a posterior-to-anterior gradient. Cortical reductions were greater than the subcortical during development, while the opposite held in aging. The pattern of lateral cortical changes was similar across development and aging, but the pronounced medial temporal reduction in aging was not precast in development. Converging patterns of change in adolescents and elderly, particularly in the medial prefrontal areas, suggest that late developed cortices are especially vulnerable to atrophy in aging. A key question in future research will be to disentangle the neurobiological underpinnings for the differences and the similarities between brain changes in development and aging. Copyright © 2012 Elsevier Inc. All rights reserved.
NASA Astrophysics Data System (ADS)
Akbaba, Hasan; Karagöz, Uğur; Selamet, Yusuf; Kantarcı, A. Gülten
2017-03-01
The aim of this study was to develop a novel iron oxide nanoparticle synthesis method with in-situ surface coating. For this purpose multiple emulsions were used as microreactors for the first time and magnetic iron oxide particles synthesized in the core of cationic solid lipid nanoparticles. DLS, SEM, TEM, VSM, Raman Spectrometer, XRD, and XPS techniques were performed for characterization of the magnetic nanoparticles. Obtained magnetic nanoparticles are superparamagnetic and no additional process was needed for surface adjustments. They are positively charged as a result of cationic lipid coating and has appropriate particle size (<30 nm) for drug or nucleic acid delivery. Structure analysis showed that magnetic core material is in the form of magnetite. Saturation magnetization value was measured as 15-17 emu g-1 for lipid coated magnetic nanoparticles obtained by multiple emulsion method which is reasonably sufficient for magnetic targeting.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Esa, Mohammad Faris Mohammad; Hassan, Ibrahim Haji; Rahim, Faszly
Magnetic material such as magnetite are known as particles that respond to external magnetic field with their ferromagnetic properties as they are believed contribute to in responding to the geomagnetic field. These particles are used by terrestrial animals such as termites for navigation and orientation. Since our earth react as giant magnetic bar, the magnitude of this magnetic field present by intensity and direction (inclination and direction). The magnetic properties and presence of magnetite in termites Macrotermes gilvus, common mound-building termite were tested. M. gilvus termites was tested with a Vibrating Sample Magnetometer VSM to determine the magnetic properties ofmore » specimen. The crushed body sample was characterized with X-Ray Diffraction XRD to show the existent of magnetic material (magnetite) in the specimens. Results from VSM indicate that M. gilvus has diamagnetism properties. The characterization by XRD shows the existent of magnetic material in our specimen in low concentration.« less
Effects of aging on neuromagnetic mismatch responses to pitch changes.
Cheng, Chia-Hsiung; Baillet, Sylvain; Hsiao, Fu-Jung; Lin, Yung-Yang
2013-06-07
Although aging-related alterations in the auditory sensory memory and involuntary change discrimination have been widely studied, it remains controversial whether the mismatch negativity (MMN) or its magnetic counterpart (MMNm) is modulated by physiological aging. This study aimed to examine the effects of aging on mismatch activity to pitch deviants by using a whole-head magnetoencephalography (MEG) together with distributed source modeling analysis. The neuromagnetic responses to oddball paradigms consisting of standards (1000 Hz, p=0.85) and deviants (1100 Hz, p=0.15) were recorded in healthy young (n=20) and aged (n=18) male adults. We used minimum norm estimate of source reconstruction to characterize the spatiotemporal neural dynamics of MMNm responses. Distributed activations to MMNm were identified in the bilateral fronto-temporo-parietal areas. Compared to younger participants, the elderly exhibited a significant reduction of cortical activation in bilateral superior temporal guri, superior temporal sulci, inferior fontal gyri, orbitofrontal cortices and right inferior parietal lobules. In conclusion, our results suggest an aging-related decline in auditory sensory memory and automatic change detection as indexed by MMNm. Copyright © 2013 Elsevier Ireland Ltd. All rights reserved.
NASA Technical Reports Server (NTRS)
Alston, W. B.
1980-01-01
The contributions of individual resin components to total resin weight loss in 600 F air aged Celion 6000/PMR-15 polyimide composites were determined from the overall resin weight loss in the composite by chemically separating the PMR-15 matrix resin into its monomeric components. The individual resin components were also analyzed by spectroscopic techniques in order to elucidate curing and degradation mechanisms of the PMR-15 matrix resin. The isothermal weight loss of the individual resin components during prolonged 600 F thermo-oxidative aging of the composite was correlated to the changes observed in the Fourier Transform infrared spectra and Fourier Transform nuclear magnetic resonance spectra of the individual resin components. The correlation was used to identify the molecular site of the thermo-oxidative changes in PMR-15 polyimide matrix resin during 600 F curing the prolonged 600 F thermo-oxidative aging.
Wandschneider, Britta; Centeno, Maria; Vollmar, Christian; Symms, Mark; Thompson, Pamela J.; Duncan, John S.
2014-01-01
Juvenile myoclonic epilepsy is a heritable idiopathic generalized epilepsy syndrome, characterized by myoclonic jerks and frequently triggered by cognitive effort. Impairment of frontal lobe cognitive functions has been reported in patients with juvenile myoclonic epilepsy and their unaffected siblings. In a recent functional magnetic resonance imaging study we reported abnormal co-activation of the motor cortex and increased functional connectivity between the motor system and prefrontal cognitive networks during a working memory paradigm, providing an underlying mechanism for cognitively triggered jerks. In this study, we used the same task in 15 unaffected siblings (10 female; age range 18–65 years, median 40) of 11 of those patients with juvenile myoclonic epilepsy (six female; age range 22–54 years, median 35) and compared functional magnetic resonance imaging activations with 20 age- and gender-matched healthy control subjects (12 female; age range 23–46 years, median 30.5). Unaffected siblings showed abnormal primary motor cortex and supplementary motor area co-activation with increasing cognitive load, as well as increased task-related functional connectivity between motor and prefrontal cognitive networks, with a similar pattern to patients (P < 0.001 uncorrected; 20-voxel threshold extent). This finding in unaffected siblings suggests that altered motor system activation and functional connectivity is not medication- or seizure-related, but represents a potential underlying mechanism for impairment of frontal lobe functions in both patients and siblings, and so constitutes an endophenotype of juvenile myoclonic epilepsy. PMID:25001494
Disrupted topology of the resting state structural connectome in middle-aged APOE ε4 carriers.
Korthauer, L E; Zhan, L; Ajilore, O; Leow, A; Driscoll, I
2018-05-24
The apolipoprotein E (APOE) ε4 allele is the best characterized genetic risk factor for Alzheimer's disease to date. Older APOE ε4 carriers (aged 60 + years) are known to have disrupted structural and functional connectivity, but less is known about APOE-associated network integrity in middle age. The goal of this study was to characterize APOE-related differences in network topology in middle age, as disentangling the early effects of healthy versus pathological aging may aid early detection of Alzheimer's disease and inform treatments. We performed resting state functional magnetic resonance imaging (rs-fMRI) and diffusion tensor imaging (DTI) in healthy, cognitively normal, middle-aged adults (age 40-60; N = 76, 38 APOE ε4 carriers). Graph theoretical analysis was used to calculate local and global efficiency of 1) a whole brain rs-fMRI network; 2) a whole brain DTI network; and 3) the resting state structural connectome (rsSC), an integrated functional-structural network derived using functional-by-structural hierarchical (FSH) mapping. Our results indicated no APOE ε4-associated differences in network topology of the rs-fMRI or DTI networks alone. However, ε4 carriers had significantly lower global and local efficiency of the integrated rsSC compared to non-carriers. Furthermore, ε4 carriers were less resilient to targeted node failure of the rsSC, which mimics the neuropathological process of Alzheimer's disease. Collectively, these findings suggest that integrating multiple neuroimaging modalities and employing graph theoretical analysis may reveal network-level vulnerabilities that may serve as biomarkers of age-related cognitive decline in middle age, decades before the onset of overt cognitive impairment. Copyright © 2018. Published by Elsevier Inc.
Gandhi, Ashish C; Li, Tai-Yue; Chan, Ting Shan; Wu, Sheng Yun
2018-05-09
With the evolution of synthesis and the critical characterization of core-shell nanostructures, short-range magnetic correlation is of prime interest in employing their properties to develop novel devices and widespread applications. In this regard, a novel approach of the magnetic core-shell saturated magnetization (CSSM) cylinder model solely based on the contribution of saturated magnetization in one-dimensional CrO₂/Cr₂O₃ core-shell nanorods (NRs) has been developed and applied for the determination of core-diameter and shell-thickness. The nanosized effect leads to a short-range magnetic correlation of ferromagnetic core-CrO₂ extracted from CSSM, which can be explained using finite size scaling method. The outcome of this study is important in terms of utilizing magnetic properties for the critical characterization of core-shell nanomagnetic materials.
McCarthy, Hazel; Skokauskas, Norbert; Mulligan, Aisling; Donohoe, Gary; Mullins, Diane; Kelly, John; Johnson, Katherine; Fagan, Andrew; Gill, Michael; Meaney, James; Frodl, Thomas
2013-12-01
The neurobiological underpinnings of attention-deficit/hyperactivity disorder (ADHD) and particularly those associated with the persistence of ADHD into adulthood are not yet well understood. The correlation patterns in spontaneous neural fluctuations at rest are known as resting-state functional connectivity (RSFC) and could characterize ADHD-specific connectivity changes. To determine the specific location of possible ADHD-related differences in RSFC between adults diagnosed as having ADHD in childhood and control subjects. DESIGN Using resting-state functional magnetic resonance imaging, we calculated and compared functional connectivity from attention, affective, default, and cognitive control networks involved in the psychopathology of ADHD between the ADHD and control groups. SETTING University psychiatric service and magnetic resonance imaging research center. Sixteen drug-free adults (5 women and 11 men; mean age, 24.5 years) diagnosed with combined-type ADHD in childhood and 16 healthy controls matched for age (mean age, 24.4 years), sex, handedness, and educational level recruited from the community. Functional magnetic resonance imaging. Connectivity data from ventral and dorsal attention, affective, default, and cognitive control networks and ADHD symptoms derived from ADHD-specific rating instruments. Adults with ADHD showed significantly decreased RSFC within the attention networks and increased RSFC within the affective and default mode and the right lateralized cognitive control networks compared with healthy controls (P < .01, familywise error for whole-brain cluster correction). Lower RSFC in the ventral and dorsal attention network was significantly correlated with higher levels of ADHD symptoms (P < .001). These RSFC findings might underpin a biological basis for adult ADHD and are functionally related to persistent inattention, disturbance in cognitive control, and emotional dysregulation in adults with ADHD. These findings need to be understood in the context of all aspects of brain function in ADHD.
Raman Spectrometer for the Characterization of Advanced Materials and Nanomaterials
2016-04-18
Capannelli, F. Canepa, M. Napoletano, M.R. Cimberle, et al., Synthesis and magnetic characterization of Ni nanoparticles and Ni nanoparticles in...Hennig, R.D. Robinson, Unintended phosphorus doping of nickel nanoparticles during synthesis with TOP: a discovery through structural analysis...Davar, Z. Fereshteh, M. Salavati-Niasari, Nanoparticles Ni and NiO: Synthesis , characterization and magnetic properties, J. Alloys Compd. 476 (2009) 797–801.
Mix, Annika; Hoppenrath, Kathrin; Funke, Klaus
2015-01-01
We recently showed that intermittent theta-burst stimulation (iTBS) using transcranial magnetic stimulation strongly reduces the number of rat neocortical interneurons expressing glutamic acid decarboxylase 67 kDa (GAD67) and parvalbumin (PV), indicating changed activity of fast-spiking (FS) interneurons. In advance of in vitro studies intended to characterize changes in electrical properties of FS interneurons under these conditions, we tested whether the iTBS effect is age-dependent. Conscious Sprague-Dawley rats aged between 28 and 90 days received three blocks of iTBS at 15 min intervals. We found that iTBS-related reduction in PV+ cells was absent up to an age of 32 days, then gradually increased, and approached a maximum of about 40% reduction at an age of about 40 days. The relative number of cells expressing PV (PV+, 8-9%) did not change with age in sham-controls and also the increase in cortical c-Fos expression induced by iTBS was not principally age-dependent. However, a prominent growth of the perineuronal nets, typically surrounding the PV+ cells, exactly paralleled the increase in the iTBS effect. Based on these findings, we conclude that the functional development of the inhibitory network of PV+ interneurons with regard to intracortical synaptic connectivity is not sufficiently matured in rats younger than 35 d to enable activity-dependent modifications during iTBS. Outgrowth of the perineuronal nets and associated maturation of excitatory cortical inputs, as is characteristic for the critical cortical period, may take place before PV+ interneurons can be sufficiently activated via repetitive transcranial magnetic stimulation, allowing plastic changes of molecular phenotype and likely also synaptic plasticity. © 2014 Wiley Periodicals, Inc.
Donadel, Karina; Felisberto, Marcos D V; Laranjeira, Mauro C M
2009-06-01
Magnetic particles of iron oxide have been increasingly used in medical diagnosis by magnetic resonance imaging and in cancer therapies involving targeted drug delivery and magnetic hyperthermia. In this study we report the preparation and characterization of iron oxide particles coated with bioceramic hydroxyapatite by spray-drying. The iron oxide magnetic particles (IOMP) were coated with hydroxyapatite (HAp) by spray-drying using two IOMP/HAp ratios (0.7 and 3.2). The magnetic particles were characterized by way of scanning electronic microscopy, energy dispersive X-ray, X-ray diffraction, Fourier transformed infrared spectroscopy, flame atomic absorption spectrometry,vibrating sample magnetometry and particle size distribution (laser diffraction). The surface morphology of the coated samples is different from that of the iron oxide due to formation of hydroxyapatite coating. From an EDX analysis, it was verified that the surface of the coated magnetic particles is composed only of HAp, while the interior containsiron oxide and a few layers of HAp as expected. The results showed that spray-drying technique is an efficient and relatively inexpensive method for forming spherical particles with a core/shell structure.
Liao, Shu-Hsien; Huang, Han-Sheng; Chieh, Jen-Jie; Su, Yu-Kai; Tong, Yuan-Fu; Huang, Kai-Wen
2017-09-03
In this work, we report characterizations of biofunctionalized magnetic nanoparticles (BMNPs) associated with alpha-fetoprotein (AFP) for biomedical applications. The example BMNP in this study is anti-alpha-fetoprotein (anti-AFP) conjugated onto dextran-coated Fe₃O₄ labeled as Fe₃O₄-anti-AFP, and the target is AFP. We characterize magnetic properties, such as increments of magnetization ΔM H and effective relaxation time Δτ eff in the reaction process. It is found that both ΔM H and Δτ eff are enhanced when the concentration of AFP, Ф AFP , increases. The enhancements are due to magnetic interactions among BMNPs in magnetic clusters, which contribute extra M H after the association with M H and in turn enhance τ eff . The screening of patients carrying hepatocellular carcinoma (HCC) is verified via ΔM H /M H . The proposed method can be applied to detect a wide variety of analytes. The scaling characteristics of ΔM H /M H show the potential to develop a vibrating sample magnetometer system with low field strength for clinic applications.
Giotto magnetic field observations at the outbound quasi-parallel bow shock of Comet Halley
NASA Technical Reports Server (NTRS)
Neubauer, F. M.; Glassmeier, K. H.; Acuna, M. H.; Mariani, F.; Musmann, G.
1990-01-01
The investigation of the outbound bow shock of Comet Halley using Giotto magnetometer data leads to the following results: the shock is characterized by strong magnetic turbulence associated with an increasing background magnetic field and a change in direction by 60 deg as one goes inward. In HSE-coordinates, the observed normal turned out to be (0.544, - 0.801, 0.249). The thickness of the quasi-parallel shock was 120,000 km. The shock is shown to be a new type of shock transition called a 'draping shock'. In a draping shock with high beta in the transonic transition region, the transonic region is characterized by strong directional variations of the magnetic field. The magnetic turbulence ahead of the shock is characterized by k-vectors parallel or antiparallel to the average field (and, therefore, also to the normal of the quasi-parallel shock) and almost isotropic magnetic turbulence in the shock transition region. A model of the draping shock is proposed which also includes a hypothetical subshock in which the supersonic-subsonic transition is accomplished.
NASA Astrophysics Data System (ADS)
Yusufzai, Mohd Zaheer Khan; Vashista, M.
2018-04-01
Barkhausen Noise analysis is a popular and preferred technique for micro-structural characterization. The root mean square value and peak value of Barkhausen Noise burst are important parameters to assess the micro-hardness and residual stress. Barkhausen Noise burst can be enveloped using a curve known as Barkhausen Noise profile. Peak position of profile changes with change in micro-structure. In the present work, raw signal of Barkhausen Noise burst was obtained from Ni based sample at various magnetic field intensity to observe the effect of variation in field intensity on Barkhausen Noise burst. Raw signal was opened using MATLAB to further process for microstructure analysis. Barkhausen Noise analysis parameters such as magnetizing frequency, number of burst, high pass and low pass filter frequency were kept constant and magnetizing field was varied in wide range between 200 Oe to 1200 Oe. The processed profiles of Barkhausen Noise burst obtained at various magnetizing field intensity clearly reveals requirement of optimum magnetic field strength for better characterization of micro-structure.
2007-02-01
5d. PROJECT NUMBER Leo L. Cheng, Ph.D. 5e. TASK NUMBER 5f. WORK UNIT NUMBER 7. PERFORMING ORGANIZATION NAME(S...Scott RM, Anthony DC, Gonzalez RG, Black PM. Biochemical characterization of pediatric brain tumors by using in vivo and ex vivo magnetic resonance...Biochemical characterization of pediatric brain tumors by using in vivo and ex vivo magnetic resonance spectroscopy. J Neurosurg 2002;96: 1023–1031. 7
NASA Astrophysics Data System (ADS)
Quinton, Emily E.; Dahms, Dennis E.; Geiss, Christoph E.
2011-07-01
In order to constrain the rate of magnetic enhancement in soils, we investigated modern soils from five fluvial terraces in the eastern Wind River Range, Wyoming. Profiles up to 1.2 m deep were sampled in 5-cm intervals from hand-dug pits or natural riverbank exposures. Soils formed in fluvial terraces correlated to the Sacajawea Ridge (730-610 ka BP), Bull Lake (130-100 ka BP) and Pinedale-age (˜20 ka BP) glacial advances. One soil profile formed in Holocene-age sediment. Abundance, mineralogy, and grain size of magnetic minerals were estimated through magnetic measurements. Magnetic enhancement of the A-horizon as well as an increase in fine-grained magnetic minerals occurred mostly in Bull Lake profiles but was absent from the older profile. Such low rates of magnetic enhancement may limit the temporal resolution of paleosol-based paleoclimate reconstructions in semiarid regions even where high sedimentation rates result in multiple paleosols. A loss of ferrimagnetic and an increase in antiferromagnetic minerals occurred with age. Our findings suggest either the conversion of ferrimagnetic minerals to weakly magnetic hematite with progressing soil age, or the presence of ferrimagnetic minerals as an intermediate product of pedogenesis. Absolute and relative hematite abundance increase with age, making both useful proxies for soil age and the dating of regional glacial deposits. All coercivity proxies are consistent with each other, which suggests that observed changes in HIRM and S-ratio are representative of real changes in hematite abundance rather than shifts in coercivity distributions, even though the modified L-ratio varies widely.
Body Composition and Ectopic Lipid Changes With Biochemical Control of Acromegaly.
Bredella, Miriam A; Schorr, Melanie; Dichtel, Laura E; Gerweck, Anu V; Young, Brian J; Woodmansee, Whitney W; Swearingen, Brooke; Miller, Karen K
2017-11-01
Acromegaly is characterized by growth hormone (GH) and insulinlike growth factor-1 (IGF-1) hypersecretion, and GH and IGF-1 play important roles in regulating body composition and glucose homeostasis. The purpose of our study was to investigate body composition including ectopic lipids, measures of glucose homeostasis, and gonadal steroids in patients with active acromegaly compared with age-, body mass index (BMI)-, and sex-matched controls and to determine changes in these parameters after biochemical control of acromegaly. Cross-sectional study of 20 patients with active acromegaly and 20 healthy matched controls. Prospective study of 16 patients before and after biochemical control of acromegaly. Body composition including ectopic lipids by magnetic resonance imaging/proton magnetic resonance spectroscopy; measures of glucose homeostasis by an oral glucose tolerance test; gonadal steroids. Patients with active acromegaly had lower mean intrahepatic lipid (IHL) and higher mean fasting insulin and insulin area under the curve (AUC) values than controls. Men with acromegaly had lower mean total testosterone, sex hormone-binding globulin, and estradiol values than male controls. After therapy, homeostasis model assessment of insulin resistance, fasting insulin level, and insulin AUC decreased despite an increase in IHL and abdominal and thigh adipose tissues and a decrease in muscle mass. Patients with acromegaly were characterized by insulin resistance and hyperinsulinemia but lower IHL compared with age-, BMI-, and sex-matched healthy controls. Biochemical control of acromegaly improved insulin resistance but led to a less favorable anthropometric phenotype with increased IHL and abdominal adiposity and decreased muscle mass. Copyright © 2017 Endocrine Society
Preparation and Characterization of an Amphipathic Magnetic Nanosphere
Ji, Yongsheng; Lv, Ruihong; Xu, Zhigang; Zhao, Chuande; Zhang, Haixia
2014-01-01
The amphipathic magnetic nanospheres were synthesized using C8 and polyethylene glycol as ligands. Their morphology, structure, and composition were characterized by transmission electron microscope, Fourier transform infrared, and elementary analysis. The prepared materials presented uniform sphere with size distribution about 200 nm. The magnetic characteristics of magnetic nanomaterials were measured by vibrating sample magnetometer. The target products had a saturation magnetization value of 50 emu g−1 and superparamagnetism. The adsorption capability was also studied by static tests, and the material was applied to enrich benzenesulfonamide from calf serum. The results exhibited that the C8-PEG phase owned better adsorption capability, biocompatible property, and dispersivity in aqueous samples. PMID:24729917
Methods for characterizing magnetic footprints of perpendicular magnetic recording writer heads
Li, Shaoping; Lin, Ed; George, Zach; Terrill, Dave; Mendez, H.; Santucci, J.; Yie, Derek
2014-01-01
In this work, the magnetic footprints, along with some of its dynamic features in recording process, of perpendicular magnetic recording writer heads have been characterized by using three different techniques. Those techniques are the spin-stand stationary footprint technique, the spin-stand dynamic footprint technique, and the coherent writing technique combined with magnetic force microscope imaging method. The characteristics of those techniques have been compared to one another. It was found experimentally that the spin-stand stationary method could not precisely catch some peculiar recording dynamics of the write heads in certain conditions. The advantages and disadvantages among all those techniques are also examined and discussed in detail. PMID:24753633
NASA Astrophysics Data System (ADS)
Dekkers, Mark J.; Rochette, Pierre
1992-11-01
Results are presented of measurements of chemical remanent magnetization properties in natural goethite and in goethite samples synthesized under controlled field conditions (horizontally directed field of 0.30 mT) at 30 C and 55 C, with and without the presence of microfiber glass filters. Results indicate that both the temperature and the presence of a substrate (microfiber glass filters) affect the goethite aging process and the magnetic properties of the resulting goethite. The goethite aging from ferrihydrite was much faster at 55 C than at 30 C, likely because of increased ion diffusion velocity in solution. Results of goethite aging in the presence of other mineral substrate (gibbsite) indicate that the type of mineral substrate is important.
Sun, Jianxin; Moore, Lee; Xue, Wei; Kim, James; Zborowski, Maciej; Chalmers, Jeffrey J
2018-05-01
Magnetic separation of cells has been, and continues to be, widely used in a variety of applications, ranging from healthcare diagnostics to detection of food contamination. Typically, these technologies require cells labeled with antibody magnetic particle conjugate and a high magnetic energy gradient created in the flow containing the labeled cells (i.e., a column packed with magnetically inducible material), or dense packing of magnetic particles next to the flow cell. Such designs, while creating high magnetic energy gradients, are not amenable to easy, highly detailed, mathematic characterization. Our laboratories have been characterizing and developing analysis and separation technology that can be used on intrinsically magnetic cells or spores which are typically orders of magnitude weaker than typically immunomagnetically labeled cells. One such separation system is magnetic deposition microscopy (MDM) which not only separates cells, but deposits them in specific locations on slides for further microscopic analysis. In this study, the MDM system has been further characterized, using finite element and computational fluid mechanics software, and separation performance predicted, using a model which combines: 1) the distribution of the intrinsic magnetophoretic mobility of the cells (spores); 2) the fluid flow within the separation device; and 3) accurate maps of the values of the magnetic field (max 2.27 T), and magnetic energy gradient (max of 4.41 T 2 /mm) within the system. Guided by this model, experimental studies indicated that greater than 95% of the intrinsically magnetic Bacillus spores can be separated with the MDM system. Further, this model allows analysis of cell trajectories which can assist in the design of higher throughput systems. © 2018 Wiley Periodicals, Inc.
Observational evidence for enhanced magnetic activity of superflare stars.
Karoff, Christoffer; Knudsen, Mads Faurschou; De Cat, Peter; Bonanno, Alfio; Fogtmann-Schulz, Alexandra; Fu, Jianning; Frasca, Antonio; Inceoglu, Fadil; Olsen, Jesper; Zhang, Yong; Hou, Yonghui; Wang, Yuefei; Shi, Jianrong; Zhang, Wei
2016-03-24
Superflares are large explosive events on stellar surfaces one to six orders-of-magnitude larger than the largest flares observed on the Sun throughout the space age. Due to the huge amount of energy released in these superflares, it has been speculated if the underlying mechanism is the same as for solar flares, which are caused by magnetic reconnection in the solar corona. Here, we analyse observations made with the LAMOST telescope of 5,648 solar-like stars, including 48 superflare stars. These observations show that superflare stars are generally characterized by larger chromospheric emissions than other stars, including the Sun. However, superflare stars with activity levels lower than, or comparable to, the Sun do exist, suggesting that solar flares and superflares most likely share the same origin. The very large ensemble of solar-like stars included in this study enables detailed and robust estimates of the relation between chromospheric activity and the occurrence of superflares.
Observational evidence for enhanced magnetic activity of superflare stars
Karoff, Christoffer; Knudsen, Mads Faurschou; De Cat, Peter; Bonanno, Alfio; Fogtmann-Schulz, Alexandra; Fu, Jianning; Frasca, Antonio; Inceoglu, Fadil; Olsen, Jesper; Zhang, Yong; Hou, Yonghui; Wang, Yuefei; Shi, Jianrong; Zhang, Wei
2016-01-01
Superflares are large explosive events on stellar surfaces one to six orders-of-magnitude larger than the largest flares observed on the Sun throughout the space age. Due to the huge amount of energy released in these superflares, it has been speculated if the underlying mechanism is the same as for solar flares, which are caused by magnetic reconnection in the solar corona. Here, we analyse observations made with the LAMOST telescope of 5,648 solar-like stars, including 48 superflare stars. These observations show that superflare stars are generally characterized by larger chromospheric emissions than other stars, including the Sun. However, superflare stars with activity levels lower than, or comparable to, the Sun do exist, suggesting that solar flares and superflares most likely share the same origin. The very large ensemble of solar-like stars included in this study enables detailed and robust estimates of the relation between chromospheric activity and the occurrence of superflares. PMID:27009381
Three-tesla magnetic resonance neurography of the brachial plexus in cervical radiculopathy.
Yoshida, Takeshi; Sueyoshi, Takeshi; Suwazono, Shugo; Suehara, Masahito
2015-09-01
There have been no reports of the use of 3-Tesla magnetic resonance neurography (3T MRN) to characterize cervical radiculopathy. In particular, there are no reports of MRN of brachial plexus involvement in patients with cervical radiculopathy. We reviewed retrospectively 12 consecutive patients with cervical radiculopathy who underwent 3T MRN. The median age was 54.5 years. Eleven of 12 patients were men. The distribution of nerve-root signal abnormality was correlated with intervertebral foraminal stenosis and the presence of muscles that exhibited weakness and/or signs of denervation on electromyography. MRN abnormalities were found to extend into the distal part of the brachial plexus in 10 patients. This study demonstrates that MRN is potentially useful for diagnosis in patients with suspected cervical radiculopathy. Moreover, the finding of brachial plexus involvement on MRN may indicate a possible pathophysiological relationship between cervical radiculopathy and brachial plexopathy. © 2014 Wiley Periodicals, Inc.
Jeromel, Miran; Podobnik, Janez
2014-01-01
Background Most vertebral haemangioma are asymptomatic and discovered incidentally. Sometimes the symptomatic lesions present with radiological signs of aggressiveness and their appearance resemble other aggressive lesions (e.g. solitary plasmacytoma). Case report. We present a patient with large symptomatic aggressive haemangioma like lesion in 12th thoracic vertebra in which a magnetic resonance spectroscopy (MRS) was used to analyse fat content within the lesion. The lesion in affected vertebrae showed low fat content with 33% of fat fraction (%FF). The fat content in non-affected (1st lumbar) vertebra was as expected for patient’s age (68%). Based on MRS data, the lesion was characterized as an aggressive haemangioma. The diagnosis was confirmed with biopsy, performed during the treatment – percutaneous vertebroplasty. Conclusions The presented case shows that MRS can be used as an additional tool for evaluation of aggressiveness of vertebral haemangioma like lesions. PMID:24991203
NASA Astrophysics Data System (ADS)
Sokal, Kimberly R.; Deen, Casey P.; Mace, Gregory N.; Lee, Jae-Joon; Oh, Heeyoung; Kim, Hwihyun; Kidder, Benjamin T.; Jaffe, Daniel T.
2018-02-01
At 60 pc, TW Hydra (TW Hya) is the closest example of a star with a gas-rich protoplanetary disk, though TW Hya may be relatively old (3–15 Myr). As such, TW Hya is especially appealing for testing our understanding of the interplay between stellar and disk evolution. We present a high-resolution near-infrared spectrum of TW Hya obtained with the Immersion GRating INfrared Spectrometer (IGRINS) to re-evaluate the stellar parameters of TW Hya. We compare these data to synthetic spectra of magnetic stars produced by MoogStokes, and use sensitive spectral line profiles to probe the effective temperature, surface gravity, and magnetic field. A model with {T}{eff}=3800 K, {log} g=4.2, and B=3.0 kG best fits the near-infrared spectrum of TW Hya. These results correspond to a spectral type of M0.5 and an age of 8 Myr, which is well past the median life of gaseous disks.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Luo, Feilong; Data Storage Institute, A*STAR Agency for Science, Technology and Research, DSI Building, 5 Engineering Drive 1, Singapore 117608; Goolaup, Sarjoosing
2016-08-28
In this work, we present an efficient method for characterizing the spin orbit torque field-like term in an in-plane magnetized system using the harmonic measurement technique. This method does not require a priori knowledge of the planar and anomalous hall resistances and is insensitive to non-uniformity in magnetization, as opposed to the conventional harmonic technique. We theoretically and experimentally demonstrate that the field-like term in the Ta/Co/Pt film stack with in-plane magnetic anisotropy can be obtained by an in-plane transverse field sweep as expected, and magnetization non-uniformity is prevented by the application of fixed magnetic field. The experimental results aremore » in agreement with the analytical calculations.« less
NASA Astrophysics Data System (ADS)
Strnat, R. M. W.; Liu, S.; Strnat, K. J.
1982-03-01
Flux-loss characteristics during long-term air aging of four rare-earth-cobalt matrix magnet types were measured. Irreversible losses and reversible temperature coefficients on heating above room temperature are reported. Purely magnetic and permanent microstructure-related changes during aging were differentiated by measuring hysteresis curves before and after long-term exposure. Three commercial polymer-bonded magnets using different rare-earth-cobalt-transition metal alloys and a solder-matrix magnet with Sm(Co, Cu, Fe, Zr)7.4 were studied. They were cycled between 25 °C and maximum temperatures to 150 °C (25 ° intervals) as applicable. Aging data at 50 and 125 °C for an exposure time of 3300 h are reported. The 2-17 samples have a stability far superior to bonded 1-5. The soft metal binder imparts significantly better aging behavior on precipitation-hardened 2-17 magnet alloys above 100 °C than an epoxy resin matrix.
Williams, P. Stephen; Carpino, Francesca; Zborowski, Maciej
2010-01-01
Quadrupole magnetic field-flow fractionation is a relatively new technique for the separation and characterization of magnetic nanoparticles. Magnetic nanoparticles are often of composite nature having a magnetic component, which may be a very finely divided material, and a polymeric or other material coating that incorporates this magnetic material and stabilizes the particles in suspension. There may be other components such as antibodies on the surface for specific binding to biological cells, or chemotherapeutic drugs for magnetic drug delivery. Magnetic field-flow fractionation (MgFFF) has the potential for determining the distribution of the magnetic material among the particles in a given sample. MgFFF differs from most other forms of field-flow fractionation in that the magnetic field that brings about particle separation induces magnetic dipole moments in the nanoparticles, and these potentially can interact with one another and perturb the separation. This aspect is examined in the present work. Samples of magnetic nanoparticles were analysed under different experimental conditions to determine the sensitivity of the method to variation of conditions. The results are shown to be consistent and insensitive to conditions, although magnetite content appeared to be somewhat higher than expected. PMID:20732895
NASA Astrophysics Data System (ADS)
Li, XiaoLi; Qi, ShiFei; Jiang, FengXian; Quan, ZhiYong; Xu, XiaoHong
2013-01-01
In this review, we review the progress of research on ZnO- and In2O3-based diluted magnetic oxides (DMOs). Firstly, we present the preparation and characterization of DMOs. The former includes the preparation methods and conditions, and the latter includes the characterization techniques for measuring microstructures. Secondly, we introduce the magnetic and transport properties of DMOs, as well as the relationship between them. Thirdly, the origin and mechanism of the ferromagnetism are discussed. Fourthly, we introduce other related work, including computational work and pertinent heterogeneous structures, such as multilayers and magnetic tunnel junctions. Finally, we provide an overview and outlook for DMOs.
de la Fuente, Jesús M; Alcántara, David; Eaton, Peter; Crespo, Patricia; Rojas, Teresa C; Fernandez, Asunción; Hernando, Antonio; Penadés, Soledad
2006-07-06
The preparation, characterization and the magnetic properties of gold and gold-iron oxide glyconanoparticles (GNPs) are described. Glyconanoparticles were prepared in a single step procedure in the presence of aqueous solution of thiol functionalized neoglycoconjugates and either gold salts or both gold and iron salts. Neoglycoconjugates of lactose and maltose disaccharides with different linkers were used. Iron-free gold or gold-iron oxide GNPs with controlled gold-iron ratios were obtained. The average core-size diameters are in the range of 1.5-2.5 nm. The GNPs are fully characterized by (1)H NMR spectrometry, transmission electron microscopy (TEM), and UV-vis and X-ray absorption (XAS) spectroscopies. Inductive plasma-atomic emission spectrometry (ICP) and elemental analysis gave the average number of neoglycoconjugates per cluster. The magnetic properties were measured in a SQUID magnetometer. The most remarkable results was the observation of a permanent magnetism up to room temperature in the iron-free gold GNPs, that was not present in the corresponding gold-iron oxide GNPs.
NASA Astrophysics Data System (ADS)
Herrero-Bervera, E.; Lau, J. K. S.; Snowball, I.
2014-12-01
We have studied the rock magnetic and paleomagnetic properties of a ~205 meter-long composite core from Site M0059 (Little Belt, BSB3) and ~210 meter-long core from Site M0060 (Anholt Loch, BSB1) recovering for the most part clays, (silty) sands, sandy clays and gravel. We deployed 454 (Site M0059) and 297 (site M0060) 8-cc discrete samples at approximately every 50 cm down-core from inside the respective site splices. The magnetic susceptibility (X) of the total of 751 samples was normalized to wet sample mass. We also performed stepwise alternating field demagnetization (AF) of the NRM up to a maximum field of 80 mT and the results show that the characteristic remanent magnetization (ChRM) was isolated by a series of weak AF's, typically between 0-25 mT, and that a low field of 5 mT removed weak VRM. After the removal of the VRM overprint the NRM intensity of the two sites is characterized by a general positive relationship with (X). The inclination data from both sites show positive and negative inclination values with a certain degree of scattering around 0°. At Site M0059 the upper lithologic units show inclinations that vary within 10 degrees either side of the geoaxial dipole prediction (GAD) for this location. In contrast the inclinations of Site M0060 show greater variability: only a few of the samples from the lower units approach this site's GAD prediction, although the inclination values in the upper lithologic units are closer to the GAD prediction. Measurements of the temperature dependence of bulk susceptibility (k-T) indicate the presence of at three magnetic mineral phases, which display characteristic Curie point temperatures of 360-400°C, 520 and 575°C for both sites and an additional Curie temperature of 610°C for Site M0060. We have obtained four 14C radiometric age determinations from 4 different stratigraphic levels at site 59A. These dates range in age from 4100+/-100 to 810+/-60 years and allow us to correlate the directional data to the FENNOSTACK regional master curve (Snowball et al. 2007). An interval of relatively steep inclinations between approximately 18 m and 16 m depth in Site M0060 probably corresponds to the period of steep inclination experienced in Fennsocandia between 3090 and 2590 Cal. a BP, which is delimited by inclination features e and e1, respectively, in FENNOSTACK.
Enlarged right superior temporal gyrus in children and adolescents with autism.
Jou, Roger J; Minshew, Nancy J; Keshavan, Matcheri S; Vitale, Matthew P; Hardan, Antonio Y
2010-11-11
The superior temporal gyrus has been implicated in language processing and social perception. Therefore, anatomical abnormalities of this structure may underlie some of the deficits observed in autism, a severe neurodevelopmental disorder characterized by impairments in social interaction and communication. In this study, volumes of the left and right superior temporal gyri were measured using magnetic resonance imaging obtained from 18 boys with high-functioning autism (mean age=13.5±3.4years; full-scale IQ=103.6±13.4) and 19 healthy controls (mean age=13.7±3.0years; full-scale IQ=103.9±10.5), group-matched on age, gender, and handedness. When compared to the control group, right superior temporal gyral volumes was significantly increased in the autism group after controlling for age and total brain volume. There was no significant difference in the volume of the left superior temporal gyrus. Post-hoc analysis revealed a significant increase of the right posterior superior temporal gyral volume in the autism group, before and after controlling for age and total brain volume. Examination of the symmetry index for the superior temporal gyral volumes did not yield statistically significant between-group differences. Findings from this preliminary investigation suggest the existence of volumetric alterations in the right superior temporal gyrus in children and adolescents with autism, providing support for a neuroanatomical basis of the social perceptual deficits characterizing this severe neurodevelopmental disorder. Copyright © 2010 Elsevier B.V. All rights reserved.
Enlarged Right Superior Temporal Gyrus in Children and Adolescents with Autism
Jou, Roger J.; Minshew, Nancy J.; Keshavan, Matcheri S.; Vitale, Matthew P.; Hardan, Antonio Y.
2010-01-01
The superior temporal gyrus has been implicated in language processing and social perception. Therefore, anatomical abnormalities of this structure may underlie some of the deficits observed in autism, a severe neurodevelopmental disorder characterized by impairments in social interaction and communication. In this study, volumes of the left and right superior temporal gyri were measured using magnetic resonance imaging obtained from 18 boys with high-functioning autism (mean age = 13.5 ±3.4 years; full-scale IQ = 103.6 ±13.4) and 19 healthy controls (mean age = 13.7 ±3.0 years; full-scale IQ = 103.9 ±10.5), group-matched on age, gender, and handedness. When compared to the control group, right superior temporal gyral volumes were significantly increased in the autism group after controlling for age and total brain volume. There was no significant difference in the volume of the left superior temporal gyrus. Post-hoc analysis revealed a significant increase of the right posterior superior temporal gyral volume in the autism group, before and after controlling for age and total brain volume. Examination of the symmetry index for the superior temporal gyral volumes did not yield statistically significant between-group differences. Findings from this preliminary investigation suggest the existence of volumetric alterations in the right superior temporal gyrus in children and adolescents with autism, providing support for a neuroanatomical basis of the social perceptual deficits characterizing this severe neurodevelopmental disorder. PMID:20833154
Fleisher, Adam S; Chen, Kewei; Quiroz, Yakeel T; Jakimovich, Laura J; Gutierrez Gomez, Madelyn; Langois, Carolyn M; Langbaum, Jessica B S; Roontiva, Auttawut; Thiyyagura, Pradeep; Lee, Wendy; Ayutyanont, Napatkamon; Lopez, Liliana; Moreno, Sonia; Muñoz, Claudia; Tirado, Victoria; Acosta-Baena, Natalia; Fagan, Anne M; Giraldo, Margarita; Garcia, Gloria; Huentelman, Matthew J; Tariot, Pierre N; Lopera, Francisco; Reiman, Eric M
2015-03-01
Age-associated changes in brain imaging and fluid biomarkers are characterized and compared in presenilin 1 (PSEN1)E280A mutation carriers and noncarriers from the world's largest known autosomal dominant Alzheimer disease (AD) kindred. To characterize and compare age-associated changes in brain imaging and fluid biomarkers in PSEN1 E280A mutation carriers and noncarriers. Cross-sectional measures of 18F-florbetapir positron emission tomography, 18F-fludeoxyglucose positron emission tomography, structural magnetic resonance imaging, cerebrospinal fluid (CSF), and plasma biomarkers of AD were assessed from 54 PSEN1 E280A kindred members (age range, 20-59 years). We used brain mapping algorithms to compare regional cerebral metabolic rates for glucose and gray matter volumes in cognitively unimpaired mutation carriers and noncarriers. We used regression analyses to characterize associations between age and the mean cortical to pontine 18F-florbetapir standard uptake value ratios, precuneus cerebral metabolic rates for glucose, hippocampal gray matter volume, CSF Aβ1-42, total tau and phosphorylated tau181, and plasma Aβ measurements. Age at onset of progressive biomarker changes that distinguish carriers from noncarriers was estimated using best-fitting regression models. Compared with noncarriers, cognitively unimpaired mutation carriers had significantly lower precuneus cerebral metabolic rates for glucose, smaller hippocampal volume, lower CSF Aβ1-42, higher CSF total tau and phosphorylated tau181, and higher plasma Aβ1-42 measurements. Sequential changes in biomarkers were seen at age 20 years (95% CI, 14-24 years) for CSF Aβ1-42, age 16 years (95% CI, 11-24 years) for the mean cortical 18F-florbetapir standard uptake value ratio, age 15 years (95% CI, 10-24 years) for precuneus cerebral metabolic rate for glucose, age 15 years (95% CI, 7-20 years) for CSF total tau, age 13 years (95% CI, 8-19 years) for phosphorylated tau181, and age 6 years (95% CI, 1-10 years) for hippocampal volume, with cognitive decline up to 6 years before the kindred's estimated median age of 44 years (95% CI, 43-45 years) at mild cognitive impairment diagnosis. No age-associated findings were seen in plasma Aβ1-42 or Aβ1-40. This cross-sectional study provides additional information about the course of different AD biomarkers in the preclinical and clinical stages of autosomal dominant AD.
Reynolds, Richard L.; Rosenbaum, Joseph G.; Sweetkind, Donald S.; Lanphere, Marvin A.; Robert, Andrew P.; Verosub, Kenneth L.
2000-01-01
Sedimentary and volcaniclastic rocks of the Oligocene Creede Formation fill the moat of the Creede caldera, which formed at about 26.9 Ma during the eruption of the Snowshoe Mountain Tuff. Paleomagnetic and rock magnetic studies of two cores (418 and 703 m long) that penetrated the lower half of the Creede Formation, in addition to paleomagnetic and isotopic dating studies of stratigraphically bracketing volcanic units, provide information on the age and the time span of sedimentation of the caldera fill. Normal polarity magnetization are found in Snowshoe Mountain Tuff beneath the moat sediments; in detrital-magnetite-bearing graded tuffs near the bottom of the moat fill; in an ash-fall deposit about 200 m stratigraphically about the top of core 2; and in postcaldera lava flows of the Fisher Dacite that overlie the Creede Formation. Normal polarity also characterizes detrital-magnetite-bearing tuff and sandstone unites within the caldera moat rocks that did not undergo severe sulfidic alteration. The combination of initially low magnitude of remanent magnetization and the destructive effects of subsequent diagenetic sulfidization on detrital iron oxides results in a poor paleomagnetic record for the fine-grained sedimentary rocks of the Creede Formation. these fine-grained rocks have either normal or revered polarity magnetizations that are carried by magnetite and/or maghemite. Many more apparent reversals are found that can be accommodated by any geomagnetic polarity time scale over the interval spanned by the ages of the bracketing extrusive rocks. Moreover, opposite polarity magnetization are found in specimens separated by only a few centimeters, without intervening hiatuses, and by specimens in several tuff beds, each of which represents a single depositional event. These polarity changes cannot, therefore, be attributed to detrital remanent magnetization. Many polarity changes are apparently related to chemical remanent magnetizations carried by postdepositional magnetite and maghemite that formed in rocks in which most or all detrital megnetic iron oxide was destroyed. Incipient oxidation of early diagenetic pyrite may have normal polarity Snowshoe Mountain Tuff (26.89 ± 0.0 Ma, 1 δ) and on the normal polarity postcaldera Fisher lava flows (as young as 26.23 ± 0.05 Ma, 1 δ) indicate that deposition of the Creede Formation spanned about 340-660 k.y. The intermittently defined normal polarity magnetization for the caldera-fill sequence, compared with different versions of the geomagnetic polarity time scale, is consistent with the shorter time span.
Therapeutic magnetic microcarriers characterization by measuring magnetophoretic attributes
NASA Astrophysics Data System (ADS)
Vidal Ibacache, Guillermo
Micro/nano robots are considered a promising approach to conduct minimally invasive interventions. We have proposed to embed magnetic nanoparticles in therapeutic or diagnostic agents in order to magnetically control them. A modified clinical Magnetic Resonance Imaging (MRI) scanner is used to provide the driving force that allows these magnetically embedded microcarriers to navigate the vascular human network. By using specific Magnetic Resonance (MR) gradient sequences this method has been validated in previous research works. Magnetophoresis is the term used to describe the fact that a magnetic particle changes its trajectory under the influence of a magnetic force while being carried by a fluid flow. This movement depends on the particle's magnetic characteristics, the particle's geometric shape, the fluid flow's attributes and other factors. In our proposed method, magnetic microcarriers can be produced in several different ways, and so their response will differ to the same magnetic force and fluid flow conditions. The outcome of the therapeutic treatment using our method depends on the adequate selection of the therapeutic and/or diagnosis agents to be used. The selected therapeutic and/or diagnosis magnetic microcarrier also influences the selection of the MR gradient sequence that best fit for a given treatment. This master's thesis presents the design of a device intended to assess the magnetophoretic properties of magnetic therapeutic microcarriers and/or diagnostic agents. Such characterization is essential for determining the optimal sequences of magnetic gradients to deflect their trajectory through relatively complex vascular networks in order to reach a pre-defined target. A microfluidic device was fabricated to validate the design. Magnetophoretic velocities are measured and a simple tracking method is proposed. The preliminary experimental results indicate that, despite some limitations, the proposed technique has the potential to be appropriate to characterize any drug and/or diagnosis magnetic microcarrier containing different magnetic nanoparticle content.
Zhang, Zhan-Chi; Luan, Feng; Xie, Chun-Yan; Geng, Dan-Dan; Wang, Yan-Yong; Ma, Jun
2015-06-01
In the aging brain, cognitive function gradually declines and causes a progressive reduction in the structural and functional plasticity of the hippocampus. Transcranial magnetic stimulation is an emerging and novel neurological and psychiatric tool used to investigate the neurobiology of cognitive function. Recent studies have demonstrated that low-frequency transcranial magnetic stimulation (≤1 Hz) ameliorates synaptic plasticity and spatial cognitive deficits in learning-impaired mice. However, the mechanisms by which this treatment improves these deficits during normal aging are still unknown. Therefore, the current study investigated the effects of transcranial magnetic stimulation on the brain-derived neurotrophic factor signal pathway, synaptic protein markers, and spatial memory behavior in the hippocampus of normal aged mice. The study also investigated the downstream regulator, Fyn kinase, and the downstream effectors, synaptophysin and growth-associated protein 43 (both synaptic markers), to determine the possible mechanisms by which transcranial magnetic stimulation regulates cognitive capacity. Transcranial magnetic stimulation with low intensity (110% average resting motor threshold intensity, 1 Hz) increased mRNA and protein levels of brain-derived neurotrophic factor, tropomyosin receptor kinase B, and Fyn in the hippocampus of aged mice. The treatment also upregulated the mRNA and protein expression of synaptophysin and growth-associated protein 43 in the hippocampus of these mice. In conclusion, brain-derived neurotrophic factor signaling may play an important role in sustaining and regulating structural synaptic plasticity induced by transcranial magnetic stimulation in the hippocampus of aging mice, and Fyn may be critical during this regulation. These responses may change the structural plasticity of the aging hippocampus, thereby improving cognitive function.
Ageing effects on the magnetic properties of Mn12-based Acetate and Stearate SMMs
NASA Astrophysics Data System (ADS)
Verma, Apoorva; Verma, Shilpi; Singh, Priti; Gupta, Anurag
2017-10-01
A study of ageing effects on the magnetic properties of Single-Molecule-Magnets (SMMs) of the Mn12 based Acetate, ([Mn12O12(CH3COO)16(H2O)4]·2CH3COOH·4H2O (1) and Stearate, [Mn12O12(CH3(CH2)16COO)11(CH3COO)5(H2O)4] (2) complexes has been carried out. Detailed magnetization (M) measurements as a function of temperature (T ∼ 1.8-10 K), magnetic field (H ∼ 0 to ±40 kOe) and time (t) have been performed on relatively fresh samples (1A and 2A) and samples aged for ∼4 weeks (1B and 2B) of both Mn12-Acetate and Mn12-Stearate. The blocking temperatures (TB) extracted from the measured M(T) lie between ∼3.0 and 3.4 K for all the four samples. In all cases, below TB, the M-H loops exhibit hysteresis with periodic steps. Interestingly, the ageing process leads to significant changes in the magnetic response of both the complexes. With ageing the Mn12-Acetate exhibits a large increase in the magnetization drop near zero-field, but the estimated anisotropy energy barrier (U) remains unchanged ∼71 K. Whereas, in the case of Mn12-Stearate ageing results in a change of U from ∼52 K (2A) to ∼35 K (2B). The results are discussed in terms of possible ageing induced changes in the structural and chemical environment of the SMMs.
Maruyama, H; Tanizawa, T; Uchiyama, S; Higuchi, T; Ei, K; Oda, M; Ei, I; Oya, M; Kishimoto, H; Saito, T; Miyamura, S; Takano, Y; Hasegawa, S; Kawada, K; Ueki, K; Iwafuchi, Y; Arakawa, M
1999-01-01
Pseudotumors of the craniovertebral junction (PTCVJ) are observed in long-term hemodialysis (HD) patients. There are neither criteria for diagnosis nor guidelines for screening. We attempted to determine magnetic resonance imaging (MRI) findings that could be used to detect PTCVJ, to determine the prevalence of PTCVJ, and to evaluate whether destructive spondyloarthropathy (DSA) might be a yardstick for selection of patients for MRI examination for PTCVJ. MRI were examined in 19 DSA patients (8 males, 11 females, age 61.4 +/- 7.3 years, HD duration 17.0 +/- 4.4 years) and in 20 sex-, age-, and HD-duration-matched non-DSA patients (9 males, 11 females, age 57.5 +/- 6.6 years, HD duration 17.7 +/- 4.9 years). We evaluated MRI characteristics of PTCVJ according those which occur due to rheumatoid arthritis. PTCVJ were characterized as follows: disappearance of fat pads in the upper region (supradental PTCVJ), intensity change of the 'predental triangle' in the anterior region (predental PTCVJ), and thickening of cruciform ligaments (retrodental PTCVJ). The prevalence of PTCVJ among patients undergoing HD more than 10 years was high (26 out of 39; 66.7%). The prevalence of PTCVJ was not different between DSA and non-DSA groups. We verified that the above MRI findings might be helpful in the detection of PTCVJ. These findings were observed frequently and independently also in patients with DSA. Copyright 1999 S. Karger AG, Basel
NASA Astrophysics Data System (ADS)
Arai, Kohsaku; Sakai, Hideo; Konishi, Kenji
1997-05-01
An outer shelf deposit in central Japan centered on the Olduvai normal polarity event in the reversed Matuyama chron reveals a close correlation of both the magnetic susceptibility and remanent intensity with the sedimentary cyclicities apparent in lithologies and molluscan assemblages. Two sedimentary cycles are characterized by distinctly similar, but double-peaked magnetic cyclicities. The rock-magnetic variability is primarily attributed to the relative abundance of terrigenous magnetic minerals, and the double peak of the variability is characterized by the concentration of finer-grained magnetic minerals. The concentration is suspected to be controlled by both climatic change and shifting proximity of the shoreline as a function of rise and fall of the sea level due to glacio-eustasy. Rock-magnetic study reveals the record of a 21 ka period of orbital precession cycles within the sedimentary cyclicity attributable to a 41 ka period of orbital obliquity forcing.
Muto, Shunsuke; Rusz, Ján; Tatsumi, Kazuyoshi; Adam, Roman; Arai, Shigeo; Kocevski, Vancho; Oppeneer, Peter M; Bürgler, Daniel E; Schneider, Claus M
2014-01-01
Electron magnetic circular dichroism (EMCD) allows the quantitative, element-selective determination of spin and orbital magnetic moments, similar to its well-established X-ray counterpart, X-ray magnetic circular dichroism (XMCD). As an advantage over XMCD, EMCD measurements are made using transmission electron microscopes, which are routinely operated at sub-nanometre resolution, thereby potentially allowing nanometre magnetic characterization. However, because of the low intensity of the EMCD signal, it has not yet been possible to obtain quantitative information from EMCD signals at the nanoscale. Here we demonstrate a new approach to EMCD measurements that considerably enhances the outreach of the technique. The statistical analysis introduced here yields robust quantitative EMCD signals. Moreover, we demonstrate that quantitative magnetic information can be routinely obtained using electron beams of only a few nanometres in diameter without imposing any restriction regarding the crystalline order of the specimen.
Magnetic Diagnostics on the Magnetized Shock Experiment (MSX)
NASA Astrophysics Data System (ADS)
Hutchinson, T. M.; Weber, T. E.; Boguski, J. C.; Intrator, T. P.; Smith, R. J.; Dunn, J. P.
2013-10-01
The Magnetized Shock Experiment (MSX) at Los Alamos National Laboratory was built to investigate the physics of high-Alfvénic, supercritical, magnetized shocks through the acceleration and subsequent stagnation of a Field Reversed Configuration (FRC) plasmoid against a magnetic mirror and/or plasma target. An array of high-bandwidth, multi-axis, robust, internal magnetic probes has been constructed to characterize flux compression ratios, instability formation, and turbulent macro-scale features of the post-shock plasma. The mirror magnet is mounted on a linear translation stage, providing a capability to axially move the shock layer through the probe field of view. An independent, external probe array also provides conventional information on the FRC shape, velocity, and total pressure during the formation and acceleration phases. Probe design, characterization, configuration, and initial results are presented. This work is supported by the DOE OFES and NNSA under LANS contract DE-AC52-06NA25369. LA-UR-13-25189.
Phillips, Jeffrey D.; Grauch, V.J.S.
2004-01-01
In the southern Espa?ola basin south of Santa Fe, New Mexico, weakly magnetic Santa Fe Group sediments of Oligocene to Pleistocene age, which represent the primary aquifers for the region, are locally underlain by moderately to strongly magnetic igneous and volcaniclastic rocks of Oligocene age. Where this relationship exists, the thickness of Santa Fe Group sediments, and thus the maximum thickness of the aquifers, can be estimated from quantitative analysis of high-resolution aeromagnetic data. These thickness estimates provide guidance for characterizing the ground-water resources in between scattered water wells in this area of rapid urban development and declining water supplies. This report presents one such analysis based on the two-step extended Euler method for estimating depth to magnetic sources. The results show the general form of a north-trending synclinal basin located between the Cerrillos Hills and Eldorado with northward thickening of Santa Fe Group sediments. The increase in thickness is gradual from the erosional edge on the south to a U-shaped Santa Fe embayment hinge line, north of which sediments thicken much more dramatically. Along the north-south basin axis, Santa Fe Group sediments thicken from 300 feet (91 meters) at the hinge line near latitude 35o32'30'N to 2,000 feet (610 meters) at the Cerrillos Road interchange at Interstate 25, north of latitude 35o36'N. The depth analysis indicates that, superimposed on this general synclinal form, there are many local areas where the Santa Fe Group sediments may be thickened by a few hundred feet, presumably due to erosional relief on the underlying Oligocene volcanic and volcaniclastic rocks. Some larger areas of greater apparent thickening occur where the presence of magnetic rocks directly underlying the Santa Fe Group is uncertain. Where magnetic rocks are absent beneath the Santa Fe Group, the thickness cannot be estimated from the aeromagnetic data.
NASA Astrophysics Data System (ADS)
Sheibi, M.; Bouchez, J. L.; Esmaeily, D.; Siqueira, R.
2012-03-01
The ˜136 Ma, NW-SE elongate Shir-Kuh pluton is one of the most poorly understood geological feature of Central Iran. It is composed of peraluminous rocks, corresponding to ilmenite-bearing S-type granites compositionally ranging from granodiorites to leucogranites. These rocks show a continuum in their chemistry attributed to progressive differentiation. This allows using the anisotropy of magnetic susceptibility technique to tempt establishing the relative chronology between emplacements of magma batches in the pluton. The rather low susceptibility magnitudes (Km < 400 μSI) depict a dominant paramagnetic behavior of the pluton. The magnetic fabrics data (magnetic lineation and foliation maps, K, P and T parameters), complemented by field and microstructural observations, reveal that two feeder zones at least, as characterized by areas having steep lineations ascribed to magma flow likely issued from the base of the brittle crust, served as conduits for the magmas. The early Cretaceous age of the pluton, the orientations of the feeding zones, the overall lineation directions throughout the pluton, as well as the S-type nature of the magmas call for a dextral transpressive regime which might have been active in the back-arc region located above the subducting eastern branch of the Neo-Tethys.
NASA Astrophysics Data System (ADS)
Ayari, M.; Paul-Boncour, V.; Lamloumi, J.; Percheron-Guégan, A.; Guillot, M.
2005-03-01
The study of LaNi 3.55Mn 0.4Al 0.3(Co 1-xFe x) 0.75 (0⩽ x⩽1) alloys as material for negative electrodes in Ni-MH batteries has shown that the electrochemical cycle life is strongly dependent on the amount of substituted iron. The samples have been characterized before and after 2 to 50 electrochemical cycles by scanning electron microscopy (SEM) and magnetization measurements in order to follow the decrepitation and the decomposition of the alloys. The bulk magnetic properties of the alloy show an evolution from a spin glass behaviour dominated by antiferromagnetic interactions towards a ferromagnetic behaviour as the Fe content increases. After electrochemical cycling, the alloys are partially decomposed into La hydroxide and small metallic and oxidized transition metal particles. A correlation has been established between the loss of electrochemical capacity and the alloy decomposition which reaches 45% after 50 cycles for x=1, whereas it remains limited to 10-15% for x=0 and 0.47. A model combining both SEM and magnetic results has been used to estimate the average thickness of the corrosion layer.
Paleomagnetism of the Red Dog Zn-Pb massive sulfide deposit in northern Alaska
Lewchuk, Michael T.; Leach, D.L.; Kelley, K.D.; Symons, David T. A.
2004-01-01
Paleomagnetic methods have isolated two ancient magnetizations in and around the Paleozoic shale-hosted Red Dog ore deposit in northern Alaska. A high-latitude, westerly magnetization carried by magnetite, termed characteristic remanent magnetization A, was found in rocks that have barite and/or substantial quartz replacement of barite. An intermediate- to low-latitude, southerly magnetization (characteristic remanent magnetization B) is carried by pyrrhotite and was found in rocks dominated by galena and sphalerite. The ages the two components are constrained by their relationship with geochemistry, radiometric age dating, and hypotheses for the Mesozoic tectonic history of the Brooks Range. Characteristic remanent magnetization A fails the fold test so it must postdate the end of Brookian orogenesis (??? 150 Ma). It is always found with replacement quartz that has a radiometric date (white mica from a vug, 39Ar/40Ar) of 126 Ma. The paleolatitude for characteristic remanent magnetization B is too shallow to be Mesozoic or younger, regardless of the model for the tectonic origin of northern Alaska, and must predate Brookian orogenesis. Geologic mapping suggests that most of the ore is syngenetic, formed at 330 to 340 Ma, and a radiometric date (Re-Os on pyrite) yields an age of 338 Ma. Since characteristic remanent magnetization B predates deformation, is found in mineralized rocks and is carried by pyrrhotite, it was probably acquired during the mineralizing process as well. The combined radiometric ages and paleomagnetic data sets can be best interpreted by assuming that northern Alaska was part of an accreted terrane that was translated northward by about 30?? into its current location relative to the rest of North America and then rotated counterclockwise by 50?? to 70??. This tectonic interpretation yields plausible magnetization ages for both characteristic remanent magnetization A and B. Geologic evidence, isotopic ages, and paleomagnetic data indicate formation of the deposit at a paleolatitude that is much lower than today. ?? 2004 by Economic Geology.
NASA Astrophysics Data System (ADS)
Rahbar, Mona; Shannon, Lesley; Gray, Bonnie L.
2016-05-01
We present a new magnetically actuated microfluidic valve that employs a highly magnetic composite polymer (M-CP) containing rare-earth hard-magnetic powder for its actuating element and for its valve seat. The M-CP offers much higher magnetization compared to the soft-magnetic, ferrite-based composite polymers typically used in microfluidic applications. Each valve consists of a permanently magnetized M-CP flap and valve seat mounted on a microfluidic channel system fabricated in poly(dimethylsiloxane) (PDMS). Each valve is actuated under a relatively small external magnetic field of 80 mT provided by a small permanent magnet mounted on a miniature linear actuator. The performance of the valve with different flap thicknesses is characterized. In addition, the effect of the magnetic valve seat on the valve’s performance is also characterized. It is experimentally shown that a valve with a 2.3 mm flap thickness, actuated under an 80 mT magnetic field, is capable of completely blocking liquid flow at a flow rate of 1 ml min-1 for pressures up to 9.65 kPa in microfluidic channels 200 μm wide and 200 μm deep. The valve can also be fabricated into an array for flow switching between multiple microfluidic channels under continuous flow conditions. The performance of arrays of valves for flow routing is demonstrated for flow rates up to 5 ml min-1 with larger microfluidic channels of up to 1 mm wide and 500 μm deep. The design of the valves is compatible with other commonly used polymeric microfluidic components, as well as other components that use the same novel permanently magnetic composite polymer, such as our previously reported cilia-based mixing devices.
NASA Astrophysics Data System (ADS)
Gattacceca, J.; Rochette, P.; Folco, L.; Perchiazzi, N.
2005-03-01
Thousands of micrometeorites were collected in aeolian deposits in Antarctica during the XIX PNRA expedition. Such large and well preserved population offers a good opportunity to test and develop a magnetic classification procedure, in parallel to mineralogical and geochemical characterization.
Performance prediction for a magnetostrictive actuator using a simplified model
NASA Astrophysics Data System (ADS)
Yoo, Jin-Hyeong; Jones, Nicholas J.
2018-03-01
Iron-Gallium alloys (Galfenol) are promising transducer materials that combine high magnetostriction, desirable mechanical properties, high permeability, and a wide operational temperature range. Most of all, the material is capable of operating under tensile stress, and is relatively resistant to shock. These materials are generally characterized using a solid, cylindrically-shaped specimen under controlled compressive stress and magnetization conditions. Because the magnetostriction strongly depends on both the applied stress and magnetization, the characterization of the material is usually conducted under controlled conditions so each parameter is varied independently of the other. However, in a real application the applied stress and magnetization will not be maintained constant during operation. Even though the controlled characterization measurement gives insight into standard material properties, usage of this data in an application, while possible, is not straight forward. This study presents an engineering modeling methodology for magnetostrictive materials based on a piezo-electric governing equation. This model suggests phenomenological, nonlinear, three-dimensional functions for strain and magnetic flux density responses as functions of applied stress and magnetic field. Load line performances as a function of maximum magnetic field input were simulated based on the model. To verify the modeling performance, a polycrystalline magnetostrictive rod (Fe-Ga alloy, Galfenol) was characterized under compressive loads using a dead-weight test setup, with strain gages on the rod and a magnetic field driving coil around the sample. The magnetic flux density through the Galfenol rod was measured with a sensing coil; the compressive loads were measured using a load cell on the bottom of the Galfenol rod. The experimental results are compared with the simulation results using the suggested model, showing good agreement.
The complexity of South China Sea kinematics
NASA Astrophysics Data System (ADS)
Sibuet, Jean-Claude; Gao, Jinyao; Zhao, Minghui; Wu, Jonny; Ding, Weiwei; Yeh, Yi-Ching; Lee, Chao-Shing
2016-04-01
Magnetic modeling shows that the age of the youngest South China Sea (SCS) oceanic crust is controversial (e.g. 15.5 Ma, Briais et al., JGR 1993 and 20.5 Ma, Barckhausen et al., MPG 2014). Close to the rift axis of the East sub-basin, Ar-Ar age dating of oceanic crustal rocks collected during IODP Leg 349 gives ages of 15 and 15.2 +/- 0.2 Ma (Koppers, Fall AGU meeting, 2014), which seems to favor the 15.5 Ma age given by Briais et al. modeling. However, basaltic samples might belong to a sill and not to the typical oceanic crust. As post-spreading magmatic activity (~8-13 Ma) largely masks the spreading fabric, in particular near the previously identified E-W portion of the extinct ridge axis of the East sub-basin, the published locations of the axial magnetic anomaly and spreading rates are incorrect. The compilation of available swath bathymetric data shows that if post-spreading volcanics hide the seafloor spreading magnetic fabric mostly along and near the extinct spreading axis, the whole SCS is globally characterized by rift directions following three directions: N055°in the youngest portion of the SCS, N065° and N085° in the oldest portions of the SCS (Sibuet et al., Tectonophysics 2016) suggesting the extinct ridge axis is N055° trending instead of E-W. We present an updated version of the whole SCS structural sketch based on previously published swath bathymetric trends and new detailed magnetic lineations trends compiled from an extremely dense set of magnetic data. The new structural sketch shows: - The distribution of conjugate kinematic domains, - The early opening of the NW and East sub-basins, before a jump of the rift axis, - A second ridge jump in the East basin, - The different expressions of the post-spreading magmatism in the East and SW sub-basins. In the East sub-basin, crustal magmatic intrusions led to the formation of extrusive basalts associated with the presence of numerous volcanoes (Wang et al., Geological Journal 2016). In the SW sub-basin, crustal magmatic intrusions deformed and uplifted the already formed oceanic crust and oldest overlying sediments, resulting in the formation of a double post-spreading ridge belt previously identified as the shoulders of the extinct spreading rift axis. Later on, this preliminary work will be used to identify magnetic lineations not polluted by the post-spreading magmatism. The unfolded Manila trench and proto-SCS slabs from seismic tomography indicate that the Eurasian margin has been maximum ~500 km east of the Manila trench since the proto-SCS era, and we incorporate these restored slabs to show a more complete SCS kinematic history.
Nutritional Cognitive Neuroscience: Innovations for Healthy Brain Aging.
Zamroziewicz, Marta K; Barbey, Aron K
2016-01-01
Nutritional cognitive neuroscience is an emerging interdisciplinary field of research that seeks to understand nutrition's impact on cognition and brain health across the life span. Research in this burgeoning field demonstrates that many aspects of nutrition-from entire diets to specific nutrients-affect brain structure and function, and therefore have profound implications for understanding the nature of healthy brain aging. The aim of this Focused Review is to examine recent advances in nutritional cognitive neuroscience, with an emphasis on methods that enable discovery of nutrient biomarkers that predict healthy brain aging. We propose an integrative framework that calls for the synthesis of research in nutritional epidemiology and cognitive neuroscience, incorporating: (i) methods for the precise characterization of nutritional health based on the analysis of nutrient biomarker patterns (NBPs), along with (ii) modern indices of brain health derived from high-resolution magnetic resonance imaging (MRI). By integrating cutting-edge techniques from nutritional epidemiology and cognitive neuroscience, nutritional cognitive neuroscience will continue to advance our understanding of the beneficial effects of nutrition on the aging brain and establish effective nutritional interventions to promote healthy brain aging.
Nutritional Cognitive Neuroscience: Innovations for Healthy Brain Aging
Zamroziewicz, Marta K.; Barbey, Aron K.
2016-01-01
Nutritional cognitive neuroscience is an emerging interdisciplinary field of research that seeks to understand nutrition's impact on cognition and brain health across the life span. Research in this burgeoning field demonstrates that many aspects of nutrition—from entire diets to specific nutrients—affect brain structure and function, and therefore have profound implications for understanding the nature of healthy brain aging. The aim of this Focused Review is to examine recent advances in nutritional cognitive neuroscience, with an emphasis on methods that enable discovery of nutrient biomarkers that predict healthy brain aging. We propose an integrative framework that calls for the synthesis of research in nutritional epidemiology and cognitive neuroscience, incorporating: (i) methods for the precise characterization of nutritional health based on the analysis of nutrient biomarker patterns (NBPs), along with (ii) modern indices of brain health derived from high-resolution magnetic resonance imaging (MRI). By integrating cutting-edge techniques from nutritional epidemiology and cognitive neuroscience, nutritional cognitive neuroscience will continue to advance our understanding of the beneficial effects of nutrition on the aging brain and establish effective nutritional interventions to promote healthy brain aging. PMID:27375409
DOE Office of Scientific and Technical Information (OSTI.GOV)
Gaul, Alexander; Holzinger, Dennis; Müglich, Nicolas David
A magnetic domain texture has been deterministically engineered in a topographically flat exchange-biased (EB) thin film system. The texture consists of long-range periodically arranged unit cells of four individual domains, characterized by individual anisotropies, individual geometry, and with non-collinear remanent magnetizations. The texture has been engineered by a sequence of light-ion bombardment induced magnetic patterning of the EB layer system. The magnetic texture's in-plane spatial magnetization distribution and the corresponding domain walls have been characterized by scanning electron microscopy with polarization analysis (SEMPA). The influence of magnetic stray fields emerging from neighboring domain walls and the influence of the differentmore » anisotropies of the adjacent domains on the Néel type domain wall core's magnetization rotation sense and widths were investigated. It is shown that the usual energy degeneracy of clockwise and counterclockwise rotating magnetization through the walls is revoked, suppressing Bloch lines along the domain wall. Estimates of the domain wall widths for different domain configurations based on material parameters determined by vibrating sample magnetometry were quantitatively compared to the SEMPA data.« less
Preparation and characterization of biocompatible magnetic carbon nanotubes
NASA Astrophysics Data System (ADS)
Shan, Yan; Chen, Kezheng; Yu, Xuegang; Gao, Lian
2010-11-01
Magnetic carbon nanotubes consisting of multi-wall carbon nanotubes (MWNTs) core and Fe3O4 shell were successfully prepared by in situ thermal decomposition of Fe(acac)3 or FeCl3 or Fe(CO)5 in 2-pyrrolidone containing acid treated MWNTs at 240 °C with the protection of nitrogen gas. The samples were characterized by TEM, XRD, SEAD, XPS and superconducting quantum interference device. Also, their biocompatibility was compared with naked carbon nanotubes. The results showed that after coated with Fe3O4 nanoparticles, the obtained magnetic carbon nanotubes show superparamagnetic characteristic at room temperature, and their blocking temperature is about 80 K. The magnetic properties of the nanotubes are relevant to the content of magnetic particles, increasing content of magnetic nanoparticles leads to higher blocking temperature and saturation magnetization. The results of antimicrobial activities to bacterial cells (Escherichia coli) showed that the MWNTs have antimicrobial activity, while the magnetic nanotubes are biocompatible even with a higher concentration than that of MWNTs.
Characterization of compact-toroid injection during formation, translation, and field penetration
NASA Astrophysics Data System (ADS)
Matsumoto, T.; Roche, T.; Allfrey, I.; Sekiguchi, J.; Asai, T.; Gota, H.; Cordero, M.; Garate, E.; Kinley, J.; Valentine, T.; Waggoner, W.; Binderbauer, M.; Tajima, T.
2016-11-01
We have developed a compact toroid (CT) injector system for particle refueling of the advanced beam-driven C-2U field-reversed configuration (FRC) plasma. The CT injector is a magnetized coaxial plasma gun (MCPG), and the produced CT must cross the perpendicular magnetic field surrounding the FRC for the refueling of C-2U. To simulate this environment, an experimental test stand has been constructed. A transverse magnetic field of ˜1 kG is established, which is comparable to the C-2U axial magnetic field in the confinement section, and CTs are fired across it. On the test stand we have been characterizing and studying CT formation, ejection/translation from the MCPG, and penetration into transverse magnetic fields.
Characterization of compact-toroid injection during formation, translation, and field penetration.
Matsumoto, T; Roche, T; Allfrey, I; Sekiguchi, J; Asai, T; Gota, H; Cordero, M; Garate, E; Kinley, J; Valentine, T; Waggoner, W; Binderbauer, M; Tajima, T
2016-11-01
We have developed a compact toroid (CT) injector system for particle refueling of the advanced beam-driven C-2U field-reversed configuration (FRC) plasma. The CT injector is a magnetized coaxial plasma gun (MCPG), and the produced CT must cross the perpendicular magnetic field surrounding the FRC for the refueling of C-2U. To simulate this environment, an experimental test stand has been constructed. A transverse magnetic field of ∼1 kG is established, which is comparable to the C-2U axial magnetic field in the confinement section, and CTs are fired across it. On the test stand we have been characterizing and studying CT formation, ejection/translation from the MCPG, and penetration into transverse magnetic fields.
NASA Astrophysics Data System (ADS)
Ghorbani-Choghamarani, Arash; Norouzi, Masoomeh
2016-03-01
Herein, we describe a simple and efficient procedure for the preparation of 3-((3-(trisilyloxy)propyl)propionamide)-1-methylimidazolium chloride ionic liquid supported on magnetic nanoparticle (TPPA-IL-Fe3O4). The structure of this magnetic ionic liquid is fully characterized by FT-IR, TGA, XRD, VSM, SEM, EDX and DLS techniques. TPPA-IL-Fe3O4 is employed as a catalyst for the acetylation of alcohols with acetic anhydride under mild and heterogeneous conditions at room temperature with good to excellent yields. The magnetic catalyst could be readily separate from the reaction media by simple magnetic decantation, and reused several times without significant loss of its catalytic activity.
Kynast, Jana; Lampe, Leonie; Luck, Tobias; Frisch, Stefan; Arelin, Katrin; Hoffmann, Karl-Titus; Loeffler, Markus; Riedel-Heller, Steffi G; Villringer, Arno; Schroeter, Matthias L
2018-06-01
Age-related white matter hyperintensities (WMH) are a manifestation of white matter damage seen on magnetic resonance imaging (MRI). They are related to vascular risk factors and cognitive impairment. This study investigated the cognitive profile at different stages of WMH in a large community-dwelling sample; 849 subjects aged 21 to 79 years were classified on the 4-stage Fazekas scale according to hyperintense lesions seen on individual T2-weighted fluid-attenuated inversion recovery MRI scans. The evaluation of cognitive functioning included seven domains of cognitive performance and five domains of subjective impairment, as proposed by the DSM-5. For the first time, the impact of age-related WMH on Theory of Mind was investigated. Differences between Fazekas groups were analyzed non-parametrically and effect sizes were computed. Effect sizes revealed a slight overall cognitive decline in Fazekas groups 1 and 2 relative to healthy subjects. Fazekas group 3 presented substantial decline in social cognition, attention and memory, although characterized by a high inter-individual variability. WMH groups reported subjective cognitive decline. We demonstrate that extensive WMH are associated with specific impairment in attention, memory, social cognition, and subjective cognitive performance. The detailed neuropsychological characterization of WMH offers new therapeutic possibilities for those affected by vascular cognitive decline.
NASA Astrophysics Data System (ADS)
Xie, Y.; Zhang, S.
2011-12-01
The observed correlations, between the characteristic ages and dipole surface magnetic field strengths of all pulsars, can be well explained by magnetic field decay with core temperatures of 2×108 K, ˜2×107 K, and ˜105 K, for magnetars, normal radio pulsars, and millisecond pulsars, respectively; assuming that their characteristic ages are about two orders of magnitude larger than their true ages, the required core temperatures may be reduced by about a factor of 10. The magnetic decay follows a power-law and is dominated by the solenoidal component of the ambipolar diffusion mode. In this model, all NSs are assumed to have the same initial magnetic field strength, but different core temperature which does not change as the magnetic field decays. This suggests that the key distinguishing property between magnetars and normal pulsars is that magnetars were born much hotter than normal pulsars, and thus have much longer magnetic field decay time scales, resulting in higher surface magnetic field strength even with the same ages of normal pulsars. The above conclusion agrees well with the observed correlations between the surface temperatures of magnetars and other young NSs, which do not agree with the cooling dominated evolution of neutron stars. This suggests a possible scenario that heating, perhaps due to magnetic field decay, balances neutron star cooling for observed pulsars.
Modular magnetic tweezers for single-molecule characterizations of helicases.
Kemmerich, Felix E; Kasaciunaite, Kristina; Seidel, Ralf
2016-10-01
Magnetic tweezers provide a versatile toolkit supporting the mechanistic investigation of helicases. In the present article, we show that custom magnetic tweezers setups are straightforward to construct and can easily be extended to provide adaptable platforms, capable of addressing a multitude of enquiries regarding the functions of these fascinating molecular machines. We first address the fundamental components of a basic magnetic tweezers scheme and review some previous results to demonstrate the versatility of this instrument. We then elaborate on several extensions to the basic magnetic tweezers scheme, and demonstrate their applications with data from ongoing research. As our methodological overview illustrates, magnetic tweezers are an extremely useful tool for the characterization of helicases and a custom built instrument can be specifically tailored to suit the experimenter's needs. Copyright © 2016 Elsevier Inc. All rights reserved.
Multiple Brain Markers are Linked to Age-Related Variation in Cognition
Hedden, Trey; Schultz, Aaron P.; Rieckmann, Anna; Mormino, Elizabeth C.; Johnson, Keith A.; Sperling, Reisa A.; Buckner, Randy L.
2016-01-01
Age-related alterations in brain structure and function have been challenging to link to cognition due to potential overlapping influences of multiple neurobiological cascades. We examined multiple brain markers associated with age-related variation in cognition. Clinically normal older humans aged 65–90 from the Harvard Aging Brain Study (N = 186) were characterized on a priori magnetic resonance imaging markers of gray matter thickness and volume, white matter hyperintensities, fractional anisotropy (FA), resting-state functional connectivity, positron emission tomography markers of glucose metabolism and amyloid burden, and cognitive factors of processing speed, executive function, and episodic memory. Partial correlation and mediation analyses estimated age-related variance in cognition shared with individual brain markers and unique to each marker. The largest relationships linked FA and striatum volume to processing speed and executive function, and hippocampal volume to episodic memory. Of the age-related variance in cognition, 70–80% was accounted for by combining all brain markers (but only ∼20% of total variance). Age had significant indirect effects on cognition via brain markers, with significant markers varying across cognitive domains. These results suggest that most age-related variation in cognition is shared among multiple brain markers, but potential specificity between some brain markers and cognitive domains motivates additional study of age-related markers of neural health. PMID:25316342
NASA Astrophysics Data System (ADS)
Liao, Shu-Hsien; Liu, Chieh-Wen; Yang, Hong-Chang; Chen, Hsin-Hsien; Chen, Ming-Jye; Chen, Kuen-Lin; Horng, Herng-Er; Wang, Li-Min; Yang, Shieh-Yueh
2012-06-01
In this work, the spin-spin relaxation of protons in ferrofluids is characterized using a high-Tc SQUID-based detector in microtesla fields. We found that spin-spin relaxation rate is enhanced in the presence of superparamagnetic nanoparticles. The enhanced relaxation rates are attributed to the microscopic field gradients from magnetic nanoparticles that dephase protons' spins nearby. The relaxation rates decrease when temperatures increase. Additionally, the alternating current magnetic susceptibility was inversely proportional to temperature. Those characteristics explained the enhanced Brownian motion of nanoparticles at high temperatures. Characterizing the relaxation will be helpful for assaying bio-molecules and magnetic resonance imaging in microtesla fields.
Subsurface damage detection in non-ferrous systems using 3D synchronous magnetic inspection
NASA Astrophysics Data System (ADS)
Gray, David; Berry, David
2018-04-01
Prime Photonics is developing a non-destructive inspection (NDI) technology, 3-D synchronous magnetic imaging system (3-D SMIS), that uses synchronous detection of magnetic signatures resulting from ultrasonic excitation to measure both surface and subsurface flaws in conductive structures. 3-D SMIS is showing promise in a wide range of NDI/NDE uses including characterizing surface-breaking cracks in ferrous and non-ferrous materials, locating and characterizing subsurface cracks within nonferrous conductive materials (Ti 6-4 and carbon fiber composites), and characterization of subsurface residual stresses. The technology offers a non-contact, high resolution inspection technique that does not require austere environments, and can accommodate non-planar specimen geometries.
Cylinders vs. Spheres: Biofluid Shear Thinning in Driven Nanoparticle Transport
Cribb, Jeremy A.; Meehan, Timothy D.; Shah, Sheel M.; Skinner, Kwan; Superfine, Richard
2011-01-01
Increasingly, the research community applies magnetophoresis to micro and nanoscale particles for drug delivery applications and the nanoscale rheological characterization of complex biological materials. Of particular interest is the design and transport of these magnetic particles through entangled polymeric fluids commonly found in biological systems. We report the magnetophoretic transport of spherical and rod-shaped particles through viscoelastic, entangled solutions using lambda-phage DNA (λ-DNA) as a model system. In order to understand and predict the observed phenomena, we fully characterize three fundamental components: the magnetic field and field gradient, the shape and magnetic properties of the probe particles, and the macroscopic rheology of the solution. Particle velocities obtained in Newtonian solutions correspond to macroscale rheology, with forces calculated via Stokes Law. In λ-DNA solutions, nanorod velocities are 100 times larger than predicted by measured zero-shear viscosity. These results are consistent with particles experiencing transport through a shear thinning fluid, indicating magnetically driven transport in shear thinning may be especially effective and favor narrow diameter, high aspect ratio particles. A complete framework for designing single-particle magnetic-based delivery systems results when we combine a quantified magnetic system with qualified particles embedded in a characterized viscoelastic medium. PMID:20571853
NASA Astrophysics Data System (ADS)
Díaz-Michelena, M.; de Frutos, J.; Ordóñez, A. A.; Rivero, M. A.; Mesa, J. L.; González, L.; Lavín, C.; Aroca, C.; Sanz, M.; Maicas, M.; Prieto, J. L.; Cobos, P.; Pérez, M.; Kilian, R.; Baeza, O.; Langlais, B.; Thébault, E.; Grösser, J.; Pappusch, M.
2017-09-01
In space instrumentation, there is currently no instrument dedicated to susceptibly or complete magnetization measurements of rocks. Magnetic field instrument suites are generally vector (or scalar) magnetometers, which locally measure the magnetic field. When mounted on board rovers, the electromagnetic perturbations associated with motors and other elements make it difficult to reap the benefits from the inclusion of such instruments. However, magnetic characterization is essential to understand key aspects of the present and past history of planetary objects. The work presented here overcomes the limitations currently existing in space instrumentation by developing a new portable and compact multi-sensor instrument for ground breaking high-resolution magnetic characterization of planetary surfaces and sub-surfaces. This new technology introduces for the first time magnetic susceptometry (real and imaginary parts) as a complement to existing compact vector magnetometers for planetary exploration. This work aims to solve the limitations currently existing in space instrumentation by means of providing a new portable and compact multi-sensor instrument for use in space, science and planetary exploration to solve some of the open questions on the crustal and more generally planetary evolution within the Solar System.
SYNTHESIS of MOLECULE/POLYMER-BASED MAGNETIC MATERIALS
DOE Office of Scientific and Technical Information (OSTI.GOV)
Miller, Joel S.
2016-02-01
We have synthesized and characterized several families of organic-based magnets, a new area showing that organic species can exhibit the technologically important property of magnetic ordering. Thin film magnets with ordering temperatures exceeding room temperature have been exceeded. Hence, organic-based magnets represent a new class of materials that exhibit magnetic ordering and do not require energy-intensive metallurgical processing and are based upon Earth-abundant elements.
NASA Astrophysics Data System (ADS)
Freedman, D.; Petronis, M. S.; Siddoway, C. S.
2012-12-01
In the Colorado Front Range, an array of sandstone dikes has intrigued geologists for over a century (Cross 1894,GSAB, 5, 525). Within their crystalline host, the dikes reach widths >7m and have a lateral extent of 70km along the Ute Pass Fault (UPF). The essential questions of sediment source, emplacement mode, and age of the dikes are unanswered. We present new paleomagnetic, rock magnetic, and anisotropy of magnetic susceptibility (AMS) results used to determine the age and emplacement behavior of the dikes. The eleven dikes selected for magnetic studies have sharp, planar margins, and share the systematic geometry of the NW striking subvertical dike array. They exhibit little or no overprint by brittle fracturing/shear associated with the UPF. Our approach involved the use of paleomagnetic techniques to isolate the characteristic remanent magnetization (ChRM), which we used to limit the age of the dikes' magnetization. Anisotropy of magnetic susceptibility (AMS),arising from alignment of detrital magnetite, serves as a proxy for the orientation of flow during dike emplacement. U-Pb detrital zircon ages, obtained previously, did not provide a useful constraint on emplacement age because the dominant age matches that of the prevalent host,1.03Ga Pikes Peak Granite. IRM acquisition experiments were performed to identify the principal magnetic phases as a mixture of Fe-Ti oxide phases, likely to be low-Ti magnetite and hematite. The sandstone consists of sub-rounded to rounded sand-sized quartz, angular feldspar (<5%), and detrital magnetite; selected samples have uniform grain size and uniform color arising from hematite cement. Although direct cover relationships are not preserved, a portion of the study sites are proximal to in situ near-horizontal sedimentary cover rocks that offer evidence against large tectonic rotation. Cores were collected using a gas-powered drill with a diamond bit and oriented using a sun compass. Where possible, cores were obtained on paired margins to test for directionality of flow using AMS. Paleomagnetic results reveal a magnetization carried by both magnetite and hematite. Laboratory unblocking temperatures for most samples are >600°C. Some samples carry a characteristic remanent magnetization (ChRM) of NW declination with shallow positive inclination, while others yield a characteristic remanent magnetization of SE declination with shallow inclination. By correlation with paleomagnetic results from the region, our findings indicate an age Permian or older. The NW directed ChRM may signify a magnetization of Neoproterozoic age, while the SE directed ChRM is more consistent with a Permo-Carboniferous magnetization. Our investigation of these possibilities is ongoing. Analysis of AMS for nine dike sites yielded subhorizontal strongly prolate magnetic ellipsoids. The magnetic lineation (K1) has moderate plunge and trends NW, parallel to the dike margins. Average bulk susceptibilities (Km) are low (6.39E-5 SI). The AMS characteristics, together with primary sedimentary structures point to instantaneous lateral injection due to elevated pore fluid pressures arising from high lithostatic or tectonic loads. We hypothesize that sediment production and fluid overpressure led to emplacement in a glacial or seismically active setting.
Grindability of dental magnetic alloys.
Hayashi, Eisei; Kikuchi, Masafumi; Okuno, Osamu; Kimura, Kohei
2005-06-01
In this study, the grindability of cast magnetic alloys (Fe-Pt-Nb magnetic alloy and magnetic stainless steel) was evaluated and compared with that of conventional dental casting alloys (Ag-Pd-Au alloy, Type 4 gold alloy, and cobalt-chromium alloy). Grindability was evaluated in terms of grinding rate (i.e., volume of metal removed per minute) and grinding ratio (i.e., volume ratio of metal removed compared to wheel material lost). Solution treated Fe-Pt-Nb magnetic alloy had a significantly higher grinding rate than the aged one at a grinding speed of 750-1500 m x min(-1). At 500 m x min(-1), there were no significant differences in grinding rate between solution treated and aged Fe-Pt-Nb magnetic alloys. At a lower speed of 500 m x min(-1) or 750 m x min(-1), it was found that the grinding rates of aged Fe-Pt-Nb magnetic alloy and stainless steel were higher than those of conventional casting alloys.
Neutron stars: history of the magnetic field decay
NASA Astrophysics Data System (ADS)
Igoshev, Andrei P.; Kholtygin, Alexander F.
2013-03-01
Using the data of the ATNF pulsar catalog we study the relation connected the real age t of young neutron stars (NS) and their spin-down age τ. We suppose that this relation is independent from both initial period of the NS and its initial surface magnetic field, and that the laws of the surface magnetic field decay are similar for all NSs in the Milky Way. We further assume that the birth-rate of pulsars was constant during at least last 200 million years. With these assumptions we were able to restore the history of the magnetic field decay for the galactic NSs. We reconstruct the universal function f(t) = B(t)/B 0, where B 0 is the initial magnetic field and B(t) is the magnetic field of NS at the age t. The function f(t) can be fitted by a power law with power index α = -1.17.
Merlocco, Anthony; Lacro, Ronald V; Gauvreau, Kimberlee; Rabideau, Nicole; Singh, Michael N; Prakash, Ashwin
2017-10-01
Aortic stiffness measured by cardiac magnetic resonance (CMR) in connective tissue disorder (CTD) patients has been previously shown to be abnormal and to be associated with adverse aortic outcomes. The rate of increase in aortic stiffness with normal aging has been previously described. However, longitudinal changes in aortic stiffness have not been characterized in CTD patients. We examined longitudinal changes in CMR-derived aortic stiffness in children and young adults with CTDs. A retrospective analysis of 50 children and young adults (median age, 20 years; range, 0.2 to 49; 40% < 18 years old) with a CTD, and with at least 2 CMR examinations (total 152 examinations) over a median duration of 3.9 (1 to 13.2) years was performed. Aortic stiffness measures (strain, distensibility, and β stiffness index) were calculated on each examination at the aortic root (AoR), ascending aorta, and descending aorta. Longitudinal changes in parameters were analyzed using linear mixed-effects models. Aortic strain and distensibility decreased with age, whereas the β stiffness index increased at all aortic segments. The average rates of decline in distensibility (x10 -3 mm Hg -1 per 10-year increase in age) were 0.7, 1.3, and 1 at the AoR, ascending aorta, and descending aorta, respectively. The rates of decline in distensibility were not associated with the rates of AoR dilation or surgical AoR replacement. In conclusion, on serial CMR measurements in children and young adults with CTDs, aortic stiffness progressively increased with age, with rates of change only slightly higher than those previously reported in healthy adults. Copyright © 2017 Elsevier Inc. All rights reserved.
Magnetic Field Fluctuations in the High Ionosphere at Polar Latitudes: Impact of the IMF Conditions
NASA Astrophysics Data System (ADS)
De Michelis, P.; Consolini, G.; Tozzi, R.
2016-12-01
The characterization of ionospheric turbulence plays an important role for all those communication systems affected by the ionospheric medium. For instance, independently of geomagnetic latitude, ionospheric turbulence represents a considerable issue for all Global Navigation Satellite Systems (GNSS). Swarm constellation measurements of the Earth's magnetic field allow a precise characterization of ionospheric turbulence. This is possible using a range of indices derived from the analysis of the scaling properties of the geomagnetic field. In particular, by the scaling properties of the 1st order structure function, a scale index can be obtained, with a consequent characterization of the degree of persistence of the fluctuations and of their spectral properties. The knowledge of this index provides a global characterization of the nature and level of ionospheric turbulence on a local scale, which can be displayed along a single satellite orbit or through maps over the region of interest. The present work focuses on the analysis of the scaling properties of the 1st order structure function of magnetic field fluctuations measured by Swarm constellation at polar latitudes in the Northern Hemisphere. They are studied according to different interplanetary magnetic field conditions and Earth's seasons to characterize the possible drivers of magnetic field variability. The obtained results are discussed in the framework of Sun-Earth relationship and ionospheric polar convection. This work is supported by the Italian National Program for Antarctic Research (PNRA) Research Project 2013/AC3.08
Roussis, S G
2001-08-01
The automated acquisition of the product ion spectra of all precursor ions in a selected mass range by using a magnetic sector/orthogonal acceleration time-of-flight (oa-TOF) tandem mass spectrometer for the characterization of complex petroleum mixtures is reported. Product ion spectra are obtained by rapid oa-TOF data acquisition and simultaneous scanning of the magnet. An analog signal generator is used for the scanning of the magnet. Slow magnet scanning rates permit the accurate profiling of precursor ion peaks and the acquisition of product ion spectra for all isobaric ion species. The ability of the instrument to perform both high- and low-energy collisional activation experiments provides access to a large number of dissociation pathways useful for the characterization of precursor ions. Examples are given that illustrate the capability of the method for the characterization of representative petroleum mixtures. The structural information obtained by the automated MS/MS experiment is used in combination with high-resolution accurate mass measurement results to characterize unknown components in a polar extract of a refinery product. The exhaustive mapping of all precursor ions in representative naphtha and middle-distillate fractions is presented. Sets of isobaric ion species are separated and their structures are identified by interpretation from first principles or by comparison with standard 70-eV EI libraries of spectra. The utility of the method increases with the complexity of the samples.
The developing human brain: age-related changes in cortical, subcortical, and cerebellar anatomy.
Sussman, Dafna; Leung, Rachel C; Chakravarty, M Mallar; Lerch, Jason P; Taylor, Margot J
2016-04-01
This study is the first to characterize normal development and sex differences across neuroanatomical structures in cortical, subcortical, and cerebellar brain regions in a single large cohort. One hundred and ninety-two magnetic resonance images were examined from 96 typically developing females and 96 age-matched typically developing males from 4 to 18 years of age. Image segmentation of the cortex was conducted with CIVET, while that of the cerebellum, hippocampi, thalamus, and basal ganglia were conducted using the MAGeT algorithm. Cortical thickness analysis revealed that most cortical regions decrease linearly, while surface area increases linearly with age. Volume relative to total cerebrum followed a quadratic trend with age, with only the left supramarginal gyrus showing sexual dimorphism. Hippocampal relative volume increased linearly, while the thalamus, caudate, and putamen decreased linearly, and the cerebellum did not change with age. The relative volumes of several subcortical subregions followed inverted U-shaped trends that peaked at ~12 years of age. Many subcortical structures were found to be larger in females than in males, independently of age, while others showed a sex-by-age interaction. This study provides a comprehensive assessment of cortical, subcortical, and cerebellar growth patterns during normal development, and draws attention to the role of sex on neuroanatomical maturation throughout childhood and adolescence.
NASA Astrophysics Data System (ADS)
Ning, Shuai; Zhan, Peng; Wang, Wei-Peng; Li, Zheng-Cao; Zhang, Zheng-Jun
2014-12-01
Highly c-axis oriented un-doped zinc oxide (ZnO) thin films, each with a thickness of ~ 100 nm, are deposited on Si (001) substrates by pulsed electron beam deposition at a temperature of ~ 320 °C, followed by annealing at 650 °C in argon in a strong magnetic field. X-ray photoelectron spectroscopy (XPS), positron annihilation analysis (PAS), and electron paramagnetic resonance (EPR) characterizations suggest that the major defects generated in these ZnO films are oxygen vacancies. Photoluminescence (PL) and magnetic property measurements indicate that the room-temperature ferromagnetism in the un-doped ZnO film originates from the singly ionized oxygen vacancies whose number depends on the strength of the magnetic field applied in the thermal annealing process. The effects of the magnetic field on the defect generation in the ZnO films are also discussed.
Characterization of compact-toroid injection during formation, translation, and field penetration
DOE Office of Scientific and Technical Information (OSTI.GOV)
Matsumoto, T., E-mail: cstd14003@g.nihon-u.ac.jp; Sekiguchi, J.; Asai, T.
2016-11-15
We have developed a compact toroid (CT) injector system for particle refueling of the advanced beam-driven C-2U field-reversed configuration (FRC) plasma. The CT injector is a magnetized coaxial plasma gun (MCPG), and the produced CT must cross the perpendicular magnetic field surrounding the FRC for the refueling of C-2U. To simulate this environment, an experimental test stand has been constructed. A transverse magnetic field of ∼1 kG is established, which is comparable to the C-2U axial magnetic field in the confinement section, and CTs are fired across it. On the test stand we have been characterizing and studying CT formation,more » ejection/translation from the MCPG, and penetration into transverse magnetic fields.« less
Sex differences in normal age trajectories of functional brain networks.
Scheinost, Dustin; Finn, Emily S; Tokoglu, Fuyuze; Shen, Xilin; Papademetris, Xenophon; Hampson, Michelle; Constable, R Todd
2015-04-01
Resting-state functional magnetic resonance image (rs-fMRI) is increasingly used to study functional brain networks. Nevertheless, variability in these networks due to factors such as sex and aging is not fully understood. This study explored sex differences in normal age trajectories of resting-state networks (RSNs) using a novel voxel-wise measure of functional connectivity, the intrinsic connectivity distribution (ICD). Males and females showed differential patterns of changing connectivity in large-scale RSNs during normal aging from early adulthood to late middle-age. In some networks, such as the default-mode network, males and females both showed decreases in connectivity with age, albeit at different rates. In other networks, such as the fronto-parietal network, males and females showed divergent connectivity trajectories with age. Main effects of sex and age were found in many of the same regions showing sex-related differences in aging. Finally, these sex differences in aging trajectories were robust to choice of preprocessing strategy, such as global signal regression. Our findings resolve some discrepancies in the literature, especially with respect to the trajectory of connectivity in the default mode, which can be explained by our observed interactions between sex and aging. Overall, results indicate that RSNs show different aging trajectories for males and females. Characterizing effects of sex and age on RSNs are critical first steps in understanding the functional organization of the human brain. © 2014 Wiley Periodicals, Inc.
NASA Astrophysics Data System (ADS)
Goudie, D. J.; Fisher, C. M.; Hanchar, J. M.; Davis, W. J.; Crowley, J. L.; Ayers, J. C.
2012-12-01
We present a method for the simultaneous in situ determination of U-Th-Pb and Sm-Nd isotopes in monazite, using a laser ablation (LA) system coupled to both a magnetic sector inductively coupled plasma mass spectrometer (HR) ICP-MS and a multicollector (MC) ICP-MS. The ablated material is split using a glass Y-connector and transported simultaneously to both mass spectrometers via helium carrier gas. The MC-ICP-MS is configured to provide relative Ce, Gd, and Eu contents, in addition to Sm and Nd. This approach obtains both age (U-Pb), tracer isotope (Sm-Nd), and REE element data (Ce, Gd, and Eu), in the same ablation volume, thus reducing sampling problems associated with fine-scale zoning and other internal structures. The accuracy and precision of the U-Pb data are demonstrated using six well characterized monazite reference materials from the Geological Survey of Canada (three of which are currently used as SHRIMP standards) and agree well with previously determined ID-TIMS ages. The accuracy of the Sm-Nd isotopic data was assessed by comparison to TIMS measurements on a well-characterized in-house monazite standard. The dual LA-ICP-MS method was applied to the Birch Creek Pluton (BCP) in the White Mountains, California in a case study to test the utility of U-Th-Pb dating coupled with Sm-Nd (and Ce, Gd, Eu) isotopic data for solving geologic problems. Previous work on the Cretaceous BCP [1] used Th-Pb ages coupled with O isotopic data to constrain hydrothermal fluid events, as recorded in monazite. The original study suggested that the high delta 18O monazite in Paleozoic country rocks adjacent to the BCP grew in response to fluid alternation associated with the intrusion of the BCP, based on overlapping age with the BCP. New monazite split-stream U-Pb and Sm-Nd data show that monazite from the BCP pluton and monazite from altered country rock have homogenous and overlapping initial Nd isotopic composition, further strengthening the proposal that monazite in altered country rock can be a tracer of fluid alternation events. The split-stream U-Pb ages agrees with new high precision ID-TIMS U-Pb ages from the same monazite grains. These results demonstrate how monazite age and Sm-Nd isotopic data, coupled with delta 18O, can identify hydrothermal monazite and constrain the timing and potential sources of fluid events. [1] Ayers et al., Geology 34 (2006) 653-656.
Replacing critical rare earth materials in high energy density magnets
NASA Astrophysics Data System (ADS)
McCallum, R. William
2012-02-01
High energy density permanent magnets are crucial to the design of internal permanent magnet motors (IPM) for hybride and electric vehicles and direct drive wind generators. Current motor designs use rare earth permanent magnets which easily meet the performance goals, however, the rising concerns over cost and foreign control of the current supply of rare earth resources has motivated a search for non-rare earth based permanent magnets alloys with performance metrics which allow the design of permanent magnet motors and generators without rare earth magnets. This talk will discuss the state of non-rare-earth permanent magnets and efforts to both improve the current materials and find new materials. These efforts combine first principles calculations and meso-scale magnetic modeling with advance characterization and synthesis techniques in order to advance the state of the art in non rare earth permanent magnets. The use of genetic algorithms in first principle structural calculations, combinatorial synthesis in the experimental search for materials, atom probe microscopy to characterize grain boundaries on the atomic level, and other state of the art techniques will be discussed. In addition the possibility of replacing critical rare earth elements with the most abundant rare earth Ce will be discussed.
NASA Technical Reports Server (NTRS)
Yuan, D. W.
1984-01-01
Magnetic anomalies of the South American continent are generally more positive and variable than the oceanic anomalies. There is better correlation between the magnetic anomalies and the major tectonic elements of the continents than between the anomalies and the main tectonic elements of the adjacent oceanic areas. Oceanic areas generally show no direct correlation to the magnetic anomalies. Precambrian continental shields are mainly more magnetic than continental basins and orogenic belts. Shields differ markedly from major aulacogens which are generally characterized by negative magnetic anomalies and positive gravity anomalies. The Andean orogenic belt shows rather poor correlation with the magnetic anomalies. The magnetic data exhibit instead prominent east-west trends, which although consistent with some tectonic features, may be related to processing noise derived from data reduction procedures to correct for external magnetic field effects. The pattern over the Andes is sufficiently distinct from the generally north trending magnetic anomalies occurring in the adjacent Pacific Ocean to separate effectively the leading edge of the South American Plate from the Nazea Plate. Eastern South America is characterized by magnetic anomalies which commonly extend across the continental margin into the Atlantic Ocean.
NASA Astrophysics Data System (ADS)
Geissman, J. W.
2014-12-01
Discussion continues on the relative role of authigenic (pigment) fine-grained hematite, relative to detrital, considerably coarser specular hematite (specularite) as a carrier of geologically meaningful remanence, as a determinant of rock magnetic properties, and as a contributor to magnetic fabrics in red beds. For one, many workers commonly assume that the laboratory unblocking temperature spectra (Tlub) of a red bed dominated by authigenic pigment does not reach the maximum Tlub as approximated by the Neel temperature (~948 K) because of the ultra fine grain size of the pigment. This issue was discussed as recently as the IRM Santa Fe meeting in late June, 2014. Many laboratories routinely utilize chemical demagnetization in concert with progressive thermal demagnetization to attempt to assess the relative role of pigment vs. detrital hematite. However, the utility of chemical demagnetization has been long challenged. In studying the anisotropy of magnetic susceptibility and remanence in red beds, recent work has considered separating the contributions of both types of hematite to the fabric signal. Three different red bed "types" (siltstones of the Triassic Chugwater Group, Gros Ventre Range, Wyoming; mudrocks of lowermost Triassic Quartermaster Formation, west Texas; and siltstones to medium sandstones of Upper Cretaceous age, northwest Vietnam) are used to evaluate the effects of varying contributions by pigment hematite to remanence, rock magnetic, and magnetic fabric properties. All rocks are well-characterized petrographically, so that the modal abundance of detrital oxides is known. The Chugwater siltstones are notable because of a relatively low Tlub spectra (below about 620o C), with no evidence of a low coercivity cubic phase. Rock magnetic and magnetic fabric properties are monitored as a function of progressive chemical demagnetization to further elucidate the role of hematite pigment in rocks that have contributed much to the paleomagnetic record of Earth.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Not Available
1992-01-01
This report summarizes the results of a study of the relationship between microstructure and magnetic properties in a unique genre of ferromagnetic material characterized by a polysynthetically twinned structure which arises during solid state transformation. These results stem from the work over a period of approximately 27 months of a nominal 3 year grant period. The report also contains a proposal to extend the research project for an additional 3 years. The polytwinned structures produce an inhomogeneous magnetic medium in which the easy axis of magnetization varies quasi-periodically giving rise to special domain configurations which are expected to markedly influencemore » the mechanism of magnetization reversal and hysteresis behavior of these materials in bulk or thin films. The extraordinary permanent magnet properties exhibited by the well-known Co-Pt alloys as well as the Fe-Pt and Fe-Pd systems near the equiatomic composition derive from the formation of a polytwinned microstructure.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Not Available
1992-07-01
This report summarizes the results of a study of the relationship between microstructure and magnetic properties in a unique genre of ferromagnetic material characterized by a polysynthetically twinned structure which arises during solid state transformation. These results stem from the work over a period of approximately 27 months of a nominal 3 year grant period. The report also contains a proposal to extend the research project for an additional 3 years. The polytwinned structures produce an inhomogeneous magnetic medium in which the easy axis of magnetization varies quasi-periodically giving rise to special domain configurations which are expected to markedly influencemore » the mechanism of magnetization reversal and hysteresis behavior of these materials in bulk or thin films. The extraordinary permanent magnet properties exhibited by the well-known Co-Pt alloys as well as the Fe-Pt and Fe-Pd systems near the equiatomic composition derive from the formation of a polytwinned microstructure.« less
NASA Astrophysics Data System (ADS)
This report summarizes the results of a study of the relationship between microstructure and magnetic properties in a unique genre of ferromagnetic material characterized by a polysynthetically twinned structure which arises during solid state transformation. These results stem from the work over a period of approximately 27 months of a nominal 3 year grant period. The report also contains a proposal to extend the research project for an additional 3 years. The polytwinned structures produce an inhomogeneous magnetic medium in which the easy axis of magnetization varies quasi-periodically giving rise to special domain configurations which are expected to markedly influence the mechanism of magnetization reversal and hysteresis behavior of these materials in bulk or thin films. The extraordinary permanent magnet properties exhibited by the well-known Co-Pt alloys as well as the Fe-Pt and Fe-Pd systems near the equiatomic composition derive from the formation of a polytwinned microstructure.
Fluctuation dynamics in reconnecting current sheets
NASA Astrophysics Data System (ADS)
von Stechow, Adrian; Grulke, Olaf; Ji, Hantao; Yamada, Masaaki; Klinger, Thomas
2015-11-01
During magnetic reconnection, a highly localized current sheet forms at the boundary between opposed magnetic fields. Its steep perpendicular gradients and fast parallel drifts can give rise to a range of instabilities which can contribute to the overall reconnection dynamics. In two complementary laboratory reconnection experiments, MRX (PPPL, Princeton) and VINETA.II (IPP, Greifswald, Germany), magnetic fluctuations are observed within the current sheet. Despite the large differences in geometries (toroidal vs. linear), plasma parameters (high vs. low beta) and magnetic configuration (low vs. high magnetic guide field), similar broadband fluctuation characteristics are observed in both experiments. These are identified as Whistler-like fluctuations in the lower hybrid frequency range that propagate along the current sheet in the electron drift direction. They are intrinsic to the localized current sheet and largely independent of the slower reconnection dynamics. This contribution characterizes these magnetic fluctuations within the wide parameter range accessible by both experiments. Specifically, the fluctuation spectra and wave dispersion are characterized with respect to the magnetic topology and plasma parameters of the reconnecting current sheet.
NASA Technical Reports Server (NTRS)
Kamhawi, Hani; Huang, Wensheng; Gilland, James H.; Haag, Thomas W.; Mackey, Jonathan; Yim, John; Pinero, Luis; Williams, George; Peterson, Peter; Herman, Daniel
2017-01-01
NASA's Hall Effect Rocket with Magnetic Shielding (HERMeS) 12.5kW Technology Demonstration Unit-3 (TDU-3) has been the subject of extensive technology maturation in preparation for flight system development. Detailed performance, stability, and plume characterization tests of the thruster were performed at NASA GRC's Vacuum Facility 5 (VF-5). The TDU-3 thruster implements a magnetic topology that is identical to TDU-1. The TDU-3 boron nitride silica composite discharge channel material is different than the TDU-1 heritage boron nitride discharge channel material. Performance and stability characterization of the TDU-3 thruster was performed at discharge voltages between 300V and 600V and at discharge currents between 5A and 21.8A. The thruster performance and stability were assessed for varying magnetic field strength, cathode flow fractions between 5% and 9%, varying harness inductance, and for reverse magnet polarity. Performance characterization test results indicate that the TDU-3 thruster performance is in family with the TDU-1 levels. TDU-3's thrust efficiency of 65% and specific impulse of 2,800sec at 600V and 12.5kW exceed performance levels of SOA Hall thrusters. Thruster stability regimes were characterized with respect to the thruster discharge current oscillations (discharge current peak-to-peak and root mean square magnitudes), discharge current waveform power spectral density analysis, and maps of the current-voltage-magnetic field. Stability characterization test results indicate a stability profile similar to TDU-1. Finally, comparison of the TDU-1 and TDU-3 plume profiles found that there were negligible differences in the plasma plume characteristics between the TDU with heritage boron nitride versus the boron nitride silica composite discharge channel.
A high-resolution aeromagnetic survey over the Lanterman Range, northern Victoria Land, Antarctica
NASA Astrophysics Data System (ADS)
Ruppel, Antonia; Läufer, Andreas; Crispini, Laura; Capponi, Giovanni; Lisker, Frank
2017-04-01
During the GANOVEX XI (German North Victoria Land Expedition) in 2015-16, a high-resolution aeromagnetic survey was carried out over the Lanterman Range in northern Victoria Land (NVL). The helicopter-based survey aimed to resolve the fine structure over the so-called Lanterman Suture Zone, which represents one of the main key areas regarding geodynamic evolution of NVL during the Early Palaeozoic Ross Orogeny. This was achieved by reducing the flight line spacing to 1-2 km with 10 km tie lines and flying in a terrain-following mode. The survey was completed by ground truth magnetic susceptibility readings by using a Kappameter KM-7. The Ross-aged basement of NVL is subdivided into three tectonometamorphic so-called "terranes", comprising from W to E the Wilson-, the Bowers- and the Robertson Bay Terrane. They are generally interpreted to have formed by accretion processes at the Palaeo-Pacific active continental margin of East Gondwana in the Cambrian and Ordovician. The survey over the Lanterman Range covered parts of the two western terranes, namely the Wilson and Bowers terranes, which are separated by the Lanterman Fault Zone. This polyphase tectonic discontinuity is characterized by a belt of mafic and ultramafic rocks comprising metabasites with eclogite-facies relicts. Preliminary results show two distinct and nearly parallel magnetic lineaments in the survey area that will be further interpreted by combined magnetic susceptibility measurements and geological field data. One magnetic lineament correlates well with the known boundary between the Wilson and Bowers terranes, which comprises also a metaconglomerate belt with mafic to ultramafic clasts. The second, further easterly magnetic lineament is so far not supported by outcrops of associated highly magnetic rocks in the field. Similar parallel structures have been observed further to the southeast and seem to be offset by a major sinistral strike-slip fault zone of possibly post-Jurassic age. One tentative interpretation of this extensive, strongly linear, and about 50-60 km long magnetic feature could be that it represents remnants of the subducted Palaeo-Pacific slab underlying the Bowers/Robertson Bay terrane boundary. Future modeling of the data set will help to identify the specific nature and origin of the observed anomalies and their geodynamic significance with regard to Ross-orogenic geodynamics.
ERIC Educational Resources Information Center
van Kooij, Britt J. M.; Benders, Manon J. N. L.; Anbeek, Petronella; van Haastert, Ingrid C.; de Vries, Linda S.; Groenendaal, Floris
2012-01-01
Aim: To assess the relation between cerebellar volume and spectroscopy at term equivalent age, and neurodevelopment at 24 months corrected age in preterm infants. Methods: Magnetic resonance imaging of the brain was performed around term equivalent age in 112 preterm infants (mean gestational age 28wks 3d [SD 1wk 5d]; birthweight 1129g [SD 324g]).…
Synthesis, characterization and magnetic properties of CoxCu1-x (x ∼ 0.01 - 0.3) granular alloys
NASA Astrophysics Data System (ADS)
Dhara, S.; Roy Chowdhury, R.; Lahiri, S.; Ray, P.; Bandyopadhyay, B.
2015-01-01
Nanostructured CoCu granular alloys have been prepared by borohydride reduction of CuCl2 and CoCl2 salt solutions using cetyltrimethylammonium bromide (CTAB) as a surfactant. Characterization by inductively coupled plasma optical emission spectroscopy (ICPOES), X-ray diffraction (XRD) and transmission electron microscopy (TEM) studies yields spherical particles of CoxCu1-x (x ∼ 0.01 - 0.3) of average size 8-25 nm formed in a face-centered-cubic (fcc) lattice as in copper. Studies of zero-field-cooled/field-cooled (ZFC/FC) magnetization and thermoremanent magnetization (TRM) have been performed in the temperature range 4-300 K, and the results have been analyzed by independent particle model. At the lowest cobalt concentration (x ∼ 0.01), the alloy is superparamagnetic and there is no blocking of magnetization down to 4 K. For all other samples, the magnetization at low magnetic field is characterized by a blocking temperature distribution which is not influenced by the Co content in samples. Study of hysteresis loops shows that the magnetization at any temperature 4-300 K is a sum of ferromagnetic (FM), superparamagnetic (SPM) and paramagnetic (PM) contributions. The FM part increases and SPM part decreases with increase in Co content. However, the values of coercivity and magnetic anisotropy constant do not depend on Co content. The results suggest that CoxCu1-x alloys are formed in a spherical core-shell type structure with cobalt being concentrated near the core of particles.
NASA Astrophysics Data System (ADS)
Hung, Le Thanh; Phuoc, Nguyen N.; Wang, Xuan-Cong; Ong, C. K.
2011-08-01
A temperature dependence characterization system of microwave permeability of magnetic thin film up to 5 GHz in the temperature range from room temperature up to 423 K is designed and fabricated as a prototype measurement fixture. It is based on the near field microwave microscopy technique (NFMM). The scaling coefficient of the fixture can be determined by (i) calibrating the NFMM with a standard sample whose permeability is known; (ii) by calibrating the NFMM with an established dynamic permeability measurement technique such as shorted microstrip transmission line perturbation method; (iii) adjusting the real part of the complex permeability at low frequency to fit the value of initial permeability. The algorithms for calculating the complex permeability of magnetic thin films are analyzed. A 100 nm thick FeTaN thin film deposited on Si substrate by sputtering method is characterized using the fixture. The room temperature permeability results of the FeTaN film agree well with results obtained from the established short-circuited microstrip perturbation method. Temperature dependence permeability results fit well with the Landau-Lifshitz-Gilbert equation. The temperature dependence of the static magnetic anisotropy H_K^{sta}, the dynamic magnetic anisotropy H_K^{dyn}, the rotational anisotropy Hrot, together with the effective damping coefficient αeff, ferromagnetic resonance fFMR, and frequency linewidth Δf of the thin film are investigated. These temperature dependent magnetic properties of the magnetic thin film are important to the high frequency applications of magnetic devices at high temperatures.
Zanca, Nicola; Lambe, Andrew T.; Massoli, Paola; ...
2017-09-06
The study of secondary organic aerosol (SOA) in laboratory settings has greatly increased our knowledge of the diverse chemical processes and environmental conditions responsible for the formation of particulate matter starting from biogenic and anthropogenic volatile compounds. However, characteristics of the different experimental setups and the way they impact the composition and the timescale of formation of SOA are still subject to debate. In this study, SOA samples were generated using a potential aerosol mass (PAM) oxidation flow reactor using α-pinene, naphthalene and isoprene as precursors. The PAM reactor facilitated exploration of SOA composition over atmospherically relevant photochemical ageing timescalesmore » that are unattainable in environmental chambers. The SOA samples were analyzed using two state-of-the-art analytical techniques for SOA characterization – proton nuclear magnetic resonance ( 1H-NMR) spectroscopy and HPLC determination of humic-like substances (HULIS). Results were compared with previous Aerodyne aerosol mass spectrometer (AMS) measurements. The combined 1H-NMR, HPLC, and AMS datasets show that the composition of the studied SOA systems tend to converge to highly oxidized organic compounds upon prolonged OH exposures. Further, our 1H-NMR findings show that only α-pinene SOA acquires spectroscopic features comparable to those of ambient OA when exposed to at least 1×10 12 molec OH cm -3 × s OH exposure, or multiple days of equivalent atmospheric OH oxidation. Over multiple days of equivalent OH exposure, the formation of HULIS is observed in both α-pinene SOA and in naphthalene SOA (maximum yields: 16 and 30 %, respectively, of total analyzed water-soluble organic carbon, WSOC), providing evidence of the formation of humic-like polycarboxylic acids in unseeded SOA.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Zanca, Nicola; Lambe, Andrew T.; Massoli, Paola
The study of secondary organic aerosol (SOA) in laboratory settings has greatly increased our knowledge of the diverse chemical processes and environmental conditions responsible for the formation of particulate matter starting from biogenic and anthropogenic volatile compounds. However, characteristics of the different experimental setups and the way they impact the composition and the timescale of formation of SOA are still subject to debate. In this study, SOA samples were generated using a potential aerosol mass (PAM) oxidation flow reactor using α-pinene, naphthalene and isoprene as precursors. The PAM reactor facilitated exploration of SOA composition over atmospherically relevant photochemical ageing timescalesmore » that are unattainable in environmental chambers. The SOA samples were analyzed using two state-of-the-art analytical techniques for SOA characterization – proton nuclear magnetic resonance ( 1H-NMR) spectroscopy and HPLC determination of humic-like substances (HULIS). Results were compared with previous Aerodyne aerosol mass spectrometer (AMS) measurements. The combined 1H-NMR, HPLC, and AMS datasets show that the composition of the studied SOA systems tend to converge to highly oxidized organic compounds upon prolonged OH exposures. Further, our 1H-NMR findings show that only α-pinene SOA acquires spectroscopic features comparable to those of ambient OA when exposed to at least 1×10 12 molec OH cm -3 × s OH exposure, or multiple days of equivalent atmospheric OH oxidation. Over multiple days of equivalent OH exposure, the formation of HULIS is observed in both α-pinene SOA and in naphthalene SOA (maximum yields: 16 and 30 %, respectively, of total analyzed water-soluble organic carbon, WSOC), providing evidence of the formation of humic-like polycarboxylic acids in unseeded SOA.« less
NASA Astrophysics Data System (ADS)
Zanca, Nicola; Lambe, Andrew T.; Massoli, Paola; Paglione, Marco; Croasdale, David R.; Parmar, Yatish; Tagliavini, Emilio; Gilardoni, Stefania; Decesari, Stefano
2017-09-01
The study of secondary organic aerosol (SOA) in laboratory settings has greatly increased our knowledge of the diverse chemical processes and environmental conditions responsible for the formation of particulate matter starting from biogenic and anthropogenic volatile compounds. However, characteristics of the different experimental setups and the way they impact the composition and the timescale of formation of SOA are still subject to debate. In this study, SOA samples were generated using a potential aerosol mass (PAM) oxidation flow reactor using α-pinene, naphthalene and isoprene as precursors. The PAM reactor facilitated exploration of SOA composition over atmospherically relevant photochemical ageing timescales that are unattainable in environmental chambers. The SOA samples were analyzed using two state-of-the-art analytical techniques for SOA characterization - proton nuclear magnetic resonance (1H-NMR) spectroscopy and HPLC determination of humic-like substances (HULIS). Results were compared with previous Aerodyne aerosol mass spectrometer (AMS) measurements. The combined 1H-NMR, HPLC, and AMS datasets show that the composition of the studied SOA systems tend to converge to highly oxidized organic compounds upon prolonged OH exposures. Further, our 1H-NMR findings show that only α-pinene SOA acquires spectroscopic features comparable to those of ambient OA when exposed to at least 1 × 1012 molec OH cm-3 × s OH exposure, or multiple days of equivalent atmospheric OH oxidation. Over multiple days of equivalent OH exposure, the formation of HULIS is observed in both α-pinene SOA and in naphthalene SOA (maximum yields: 16 and 30 %, respectively, of total analyzed water-soluble organic carbon, WSOC), providing evidence of the formation of humic-like polycarboxylic acids in unseeded SOA.
NASA Astrophysics Data System (ADS)
Grancharov, Stephanie G.
I. A general introduction to the field of nanomaterials is presented, highlighting their special attributes and characteristics. Nanoparticles in general are discussed with respect to their structure, form and properties. Magnetic particles in particular are highlighted, especially the iron oxides. The importance and interest of integrating these materials with biological media is discussed, with emphasis on transferring particles from one medium to another, and subsequent modification of surfaces with different types of materials. II. A general route to making magnetic iron oxide nanoparticles is explained, both as maghemite and magnetite, including properties of the particles and characterization. A novel method of producing magnetite particles without a ligand is then presented, with subsequent characterization and properties described. III. Attempts to coat iron oxide nanoparticles with a view to creating biofunctional magnetic nanoparticles are presented, using a gold overcoating method. Methods of synthesis and characterization are examined, with unique problems to core-shell structures analyzed. IV. Solubility of nanoparticles in both aqueous and organic media is discussed and examined. The subsequent functionalization of the surface of maghemite and magnetite nanoparticles with a variety of biomaterials including block copolypeptides, phospholipids and carboxydextran is then presented. These methods are integral to the use of magnetic nanoparticles in biological applications, and therefore their properties are examined once tailored with these molecules. V. A new type of magnetic nanoparticle sensor-type device is described. This device integrates bio-and DNA-functionalized nanoparticles with conjugate functionalized silicon dioxide surfaces. These techniques to pattern particles to a surface are then incorporated into a device with a magnetic tunnel junction, which measures magnetoresistance in the presence of an external magnetic field. This configuration thereby introduces a new way to detect magnetic nanoparticles via their magnetic properties after conjugation via biological entities.
Jiang, Hongrong; Zeng, Xin; Xi, Zhijiang; Liu, Ming; Li, Chuanyan; Li, Zhiyang; Jin, Lian; Wang, Zhifei; Deng, Yan; He, Nongyue
2013-04-01
In present study, we put forward an approach to prepare three-layer core-shell Fe3O4@SiO2@Au magnetic nanocomposites via the combination of self-assembling, seed-mediated growing and multi-step chemical reduction. The Fe3O4@SiO2@Au magnetic nanocomposites were analyzed and characterized by transmission electron microscope (TEM), scanning electronic microscope (SEM), energy dispersive spectrometer analysis (EDS), Fourier transform infrared spectroscopy (FT-IR), vibrating sample magnetometer (VSM), and ultraviolet and visible spectrophotometer (UV-Vis). TEM and SEM characterizations showed that the FeO4@SiO2@Au nanocomposites were obtained successfully with three-layer structures, especially a layer of thin, smooth and continuous gold shell. The average diameter of Fe3O4@SiO2@Au nanocomposites was about 600 nm and an excellent dispersity was observed for the as-prepared nanoparticles. EDS characterizations demonstrated that the nanocomposites contained three elements of the precursors, Fe, Si, and Au. Furthermore, FT-IR showed that the silica and gold shell were coated successfully. UV-Vis and VSM characterizations showed that the Fe3O4@SiO2@Au nanocomposites exhibited good optical and magnetic property, and the saturation magnetization was 25.76 emu/g. In conclusion, the Fe3O4@SiO2@Au magnetic nanocomposites with three-layer core-shell structures were prepared. Furthermore, Fe3O4@SiO2@Au magnetic nanocomposites were modified with streptavidin (SA) successfully, and it was validated that they performed low fluorescence background, suggesting that they should have good applications especially in bioassay based on fluorescence detection through bonding the biotinylated fluorescent probes.
NASA Astrophysics Data System (ADS)
Samuel, Y. M.; Saad, R.; Muztaza, N. M.; Saidin, M. M.; Muhammad, S. B.
2018-04-01
Magnetic and geotechnical methods were used for shallow subsurface soil characterization at Sungai Batu, Kedah, (Malaysia). Ground magnetic data were collected along a survey line of length 160 m long at 2 m constant station spacing, while soil drilling using hand auger was conducted at 21 m on the survey line using 0.2 m sampling interval drilled to a depth of 5 m. Result from the processed magnetic profile data shows distribution of magnetic residuals in the range of -4.55 to 1.61 nT, with magnetic low (-4.55 nT to -0.058 nT) and were identified at distances 4 m, 10 to 16 m, 20 to 26 m, 58 m, 82 m, 104 to 106 m, 118 m, and 124 to 140 m. The magnetic lows are attributes of sediments. The result from the soil drilling shows sticky samples with variable sizes, greyish to brownish / reddish in colour, and some of the samples show the presence of shiny and black spots. The characteristics of the samples suggest the soil as a by-product of completely weathered rock; weak with high water content and classified as Grade V soil. The study concludes; integration of geophysical and geotechnical methods aided in characterizing the subsurface soil at Sungai Batu. The result was correlated with previous studies and confirms the importance of integrated approach in minimising ambiguity in interpretation.
NASA Astrophysics Data System (ADS)
Mamiya, H.; Tsujii, N.; Terada, N.; Nimori, S.; Kitazawa, H.; Hoshikawa, A.; Ishigaki, T.
2014-07-01
To clarify the universal features of spin glasses, we carefully studied slow dynamics in a geometrically frustrated magnet ZnFe2O4 with slight disorders, regarded as an "unconventional" Heisenberg spin glass, using time-resolved neutron diffractometry and magnetometry. The results indicate that "aging" can be attributed not to growth of the short-range order detected by a diffuse scattering but to aging of a hidden aperiodic correlation, as expected from theories for spin glasses. Concerning aging, peculiar behavior was found; the decay of thermoremanent magnetization is extremely accelerated if the sample is heated/cooled briefly midway through the isothermal slow relaxation. Conversely, magnetization surprisingly increases despite the absence of a magnetic field when the temperature returns after the brief heating/cooling. The behavior can be explained as a destabilization of the aged spin configuration due to the thermal perturbations and subsequent spontaneous restoration of the original spin configuration after the destabilization. Whereas such destabilization and restoration do not occur during freezing into numerous metastable states in a fixed energy landscape, these are possible in an energy landscape with a temperature-sensitive funnel-like structure. These features, consistent with the ghost domain scenario of the droplet picture, are the same as for conventional Heisenberg spin glasses such as dilute magnetic alloys and dilute magnetic semiconductors. In other words, they are universal features in Heisenberg spin glasses including unconventional ones.
Hybride magnetic nanostructure based on amino acids functionalized polypyrrole
DOE Office of Scientific and Technical Information (OSTI.GOV)
Nan, Alexandrina, E-mail: alexandrina.nan@itim-cj.ro; Bunge, Alexander; Turcu, Rodica
Conducting polypyrrole is especially promising for many commercial applications because of its unique optical, electric, thermal and mechanical properties. We report the synthesis and characterization of novel pyrrole functionalized monomers and core-shell hybrid nanostructures, consisting of a conjugated polymer layer (amino acids functionalized pyrrole copolymers) and a magnetic nanoparticle core. For functionalization of the pyrrole monomer we used several amino acids: tryptophan, leucine, phenylalanine, serine and tyrosine. These amino acids were linked via different types of hydrophobic linkers to the nitrogen atom of the pyrrole monomer. The magnetic core-shell hybrid nanostructures are characterized by various methods such as FTIR spectroscopy,more » transmission electron microscopy (TEM) and magnetic measurements.« less
NASA Astrophysics Data System (ADS)
Ruchala, T. L.; Chen, M.; Tominaga, M.; Carey, S.
2016-12-01
Kick'em Jenny (KEJ) is an active submarine volcano located in the Lesser Antilles subduction zone, 7.5 km north of the Caribbean island Grenada. KEJ, known as one of the most explosive volcanoes in Caribbean, erupted 12 times since 1939 with recent eruptions in 2001 and possibly in 2015. Multiple generations of submarine landslides and canyons have been observed in which some of them can be attributed to past eruptions. The structure of KEJ can be characterized as a 1300 m high conical profile with its summit crater located around 180 m in depth. Active hydrothermal venting and dominantly CO2 composition gas seepage take place inside this 250m diameter crater, with the most activity occurring primarily within a small ( 70 x 110 m) depression zone (inner crater). In order to characterize the subsurface structure and decipher the processes of this volcanic system, the Nautilus NA054 expedition in 2014 deployed the underwater Remotely Operated Vehicle (ROV) Hercules to conduct near-bottom geological observations and magnetometry surveys transecting KEJ's caldera. Raw magnetic data was corrected for vehicle induced magnetic noise, then merged with ROV to ship navigation at 1 HZ. To extract crustal magnetic signatures, the reduced magnetic data was further corrected for external variations such as the International Geomagnetic Reference Field and diurnal variations using data from the nearby San Juan Observatory. We produced a preliminary magnetic anomaly map of KEJ's caldera for subsequent inversion and forward modeling to delineate in situ magnetic source distribution in understanding volcanic processes. We integrated the magnetic characterization of the KEJ craters with shipboard multibeam, ROV visual descriptions, and photomosaics. Initial observations show the distribution of short wavelength scale highly magnetized source centered at the north western part of the inner crater. Although locations of gas seeps are ubiquitous over the inner crater area along ROV survey lines, some of their provinces coincide with distinctive magnetic characters, suggesting possible in situ structural or alteration boundaries (i.e. subsurface faults and hydrothermal destruction zones).
NMR Relaxometry to Characterize the Drug Structural Phase in a Porous Construct.
Thrane, Linn W; Berglund, Emily A; Wilking, James N; Vodak, David; Seymour, Joseph D
2018-06-14
Nuclear magnetic resonance (NMR) frequency spectra and T 2 relaxation time measurements, using a high-power radio frequency probe, are shown to characterize the presence of an amorphous drug in a porous silica construct. The results indicate the ability of non-solid-state NMR methods to characterize crystalline and amorphous solid structural phases in drugs. Two-dimensional T 1 - T 2 magnetic relaxation time correlation experiments are shown to monitor the impact of relative humidity on the drug in a porous silica tablet.
NASA Astrophysics Data System (ADS)
Arlensiú Ordóñez Cencerrado, Amanda; Kilian, Rolf; Díaz-Michelena, Marina
2017-04-01
Large areas of Mars and other celestial bodies are covered with basaltic lava flows and their associated craters. Depending on the individual cooling history and related single versus multi-domain status of the magnetites, as well as the global magnetic field characteristic during crystallization, such rocks could be characterized by very distinct remanent and induced magnetic signatures. Thus, a characterization of analogue craters and lava flows on Earth, and the creation of a database of their distinct magnetic parameters is of key importance for the near future exploration of planetary surfaces like Mars and the Moon. For example, three potential landing sites of the ExoMars 2020 mission include such geological scenarios. Complete on ground measurements of their distinct magnetic properties would also allow information about the characteristics of the early Martian magnetic field. As case study in the former context we selected a small crater (56°07' S, 69°42' E), which represents an agglutinated spatter cone, and its surrounding lava flows within the Pali Aike Volcano Field in Patagonia. Although the chemical composition of the basalts formed along and outside of the crater is similar, distinct local cooling, outgassing and crystallization histories are likely to produced huge differences in the magnetic signatures. With the objective to achieve a better interpretation of future more extended on ground geophysical characterization on board planetary vehicles, we performed a profound magnetic characterization of the Pali Aike crater including: • magnetic surveys with scalar, vector and gradiometric measurements providing high-resolution vector magnetic maps of the crater, • paleomagnetic data obtained from drilled oriented samples along a transect across the crater. Further laboratory data including remanence, susceptibility, coercitivity which have been also drawn in Day plots to analyse single versus multi domain status of magnetites in the basaltic ground mass, • a petrographical and chemical characterization of the magnetites by microscope and electron microprobe, • and a model that considers not exposed rock units and is able to explain the observed 3D magnetic characteristics. This could be transferred to other comparable planetary scenarios. The most important results of our investigation indicate that A vector magnetic data of rocks with highly remanent versus induced magnetic signatures high Königsberger ratios provide implications for paleofield orientations, B magnetic anomalies of up to +8000 nT can be related to different proportions of single versus multi-domain status of magnetites which reflect the local cooling histories in different sectors of the crater and its surroundings as well as on a decimeter scale within single volcanic spatter blocks and C our 3-D model is able to reproduce observed surface rock magnetic signatures together with likely signatures of underlying rock units and their spatial distribution. In the near future the above described results should be provided by a magnetic multisensor instrument combining vector and different susceptibility data as well as local demagnetization histories which is recently developed in our NEWTON EU project in advance to its inclusion on board rovers to planetary missions.
Rosero, Eric B; Peshock, Ronald M; Khera, Amit; Clagett, Patrick; Lo, Hao; Timaran, Carlos H
2011-04-01
Reference values and age-related changes of the wall thickness of the abdominal aorta have not been described in the general population. We characterized age-, race-, and gender-specific distributions, and yearly rates of change of mean aortic wall thickness (MAWT), and associations between MAWT and cardiovascular risk factors in a multi-ethnic population-based probability sample. Magnetic resonance imaging measurements of MAWT were performed on 2466 free-living white, black, and Hispanic adult subjects. MAWT race/ethnicity- and gender-specific percentile values across age were estimated using regression analyses. MAWT was greater in men than in women and increased linearly with age in all the groups and across all the percentiles. Hispanic women had the thinnest and black men the thickest aortas. Black men had the highest and white women the lowest age-related MAWT increase. Age, gender, ethnicity, smoking status, systolic blood pressure, low-density lipoprotein-cholesterol levels, high-density lipoprotein-cholesterol levels, and fasting glucose levels were independent predictors of MAWT. Age, gender, and racial/ethnic differences in MAWT distributions exist in the general population. Such differences should be considered in future investigations assessing aortic atherosclerosis and the effects of anti-atherosclerotic therapies. Published by Mosby, Inc.
NASA Astrophysics Data System (ADS)
Meller, Carola; Kontny, Agnes; Kohl, Thomas
2014-10-01
Clay minerals as products of hydrothermal alteration significantly influence the hydraulic and mechanical properties of crystalline rock. Therefore, the localization and characterization of alteration zones by downhole measurements is a great challenge for the development of geothermal reservoirs. The magnetite bearing granite of the geothermal site in Soultz-sous-Forêts (France) experienced hydrothermal alteration during several tectonic events and clay mineral formation is especially observed in alteration halos around fracture zones. During the formation of clay minerals, magnetite was oxidized into hematite, which significantly reduces the magnetic susceptibility of the granite from ferrimagnetic to mostly paramagnetic values. The aim of this study was to find out if there exists a correlation between synthetic clay content logs (SCCLs) and measurements of magnetic susceptibility on cuttings in the granite in order to characterize their alteration mineralogy. Such a correlation has been proven for core samples of the EPS1 reference well. SCCLs were created from gamma ray and fracture density logs using a neural network. These logs can localize altered fracture zones in the GPK1-4 wells, where no core material is available. Mass susceptibility from 261 cutting samples of the wells GPK1-GPK4 was compared with the neural network derived synthetic logs. We applied a combination of temperature dependent magnetic susceptibility measurements with optical and electron microscopy, and energy dispersive X-ray spectroscopy to discriminate different stages of alteration. We found, that also in the granite cuttings an increasing alteration grade is characterized by an advancing oxidation of magnetite into hematite and a reduction of magnetic susceptibility. A challenge to face for the interpretation of magnetic susceptibility data from cuttings material is that extreme alteration grades can also display increased susceptibilities due to the formation of secondary magnetite. Low magnetic susceptibility can also be attributed to primary low magnetite content, if the granite facies changes. In order to interpret magnetic susceptibility from cuttings, contaminations with iron from wear debris of the drilling tools must be eliminated. Provided that the magnetic mineralogy of the granite is known in detail, this method in combination with petrographic investigations is suited to indicate and characterize hydrothermal alteration and the appearance of clay.
Microglial activation in white matter lesions and nonlesional white matter of ageing brains.
Simpson, J E; Ince, P G; Higham, C E; Gelsthorpe, C H; Fernando, M S; Matthews, F; Forster, G; O'Brien, J T; Barber, R; Kalaria, R N; Brayne, C; Shaw, P J; Stoeber, K; Williams, G H; Lewis, C E; Wharton, S B
2007-12-01
White matter lesions (WML), a common feature in brain ageing, are classified as periventricular (PVL) or deep subcortical (DSCL), depending on their anatomical location. Microglial activation is implicated in a number of neurodegenerative diseases, but the microglial response in WML is poorly characterized and its role in pathogenesis unknown. We have characterized the microglial response in WML and control white matter using immunohistochemistry to markers of microglial activation and of proliferation. WML of brains from an unbiased population-based autopsy cohort (Medical Research Council's Cognitive Function and Ageing Study) were identified by post mortem magnetic resonance imaging and sampled for histology. PVL contain significantly more activated microglia, expressing major histocompatibility complex (MHC) class II and the costimulatory molecules B7-2 and CD40, than either control white matter (WM) or DSCL. Furthermore, we show that significantly more microglia express the replication licensing protein minichromosome maintenance protein 2 within PVL, suggesting this is a more proliferation-permissive environment than DSCL. Although microglial activation occurs in both PVL and DSCL, our findings suggest a difference in pathogenesis between these lesion-types: the ramified, activated microglia associated with PVL may reflect immune activation resulting from disruption of the blood brain barrier, while the microglia within DSCL may reflect an innate, amoeboid phagocytic phenotype. We also show that microglia in control WM from lesional cases express significantly more MHC II than control WM from nonlesional ageing brain, suggesting that WML occur in a 'field-effect' of abnormal WM.
Design and Performance of GMR Sensors for the Detection of Magnetic Microbeads in Biosensors
2003-03-19
characterize the magnetic properties of the NiFe microbeads and chemically functionalize them for use in assays. 2.3. Sensor signal...have been developed as labels for biosensing. Magnetic labels have several potential advantages over other labels. The magnetic properties of the...temperature. Although Dynal M-280 microbeads are extremely monodispersed in size and have excellent biocompatible surface properties , their magnetic
The influence of puberty on subcortical brain development.
Goddings, Anne-Lise; Mills, Kathryn L; Clasen, Liv S; Giedd, Jay N; Viner, Russell M; Blakemore, Sarah-Jayne
2014-03-01
Puberty is characterized by hormonal, physical and psychological transformation. The human brain undergoes significant changes between childhood and adulthood, but little is known about how puberty influences its structural development. Using a longitudinal sample of 711 magnetic resonance imaging scans from 275 individuals aged 7-20years, we examined how subcortical brain regions change in relation to puberty. Our regions of interest included the amygdala, hippocampus and corpus striatum including the nucleus accumbens (NA), caudate, putamen and globus pallidus (GP). Pubertal development was significantly related to structural volume in all six regions in both sexes. Pubertal development and age had both independent and interactive influences on volume for the amygdala, hippocampus and putamen in both sexes, and the caudate in females. There was an interactive puberty-by-age effect on volume for the NA and GP in both sexes, and the caudate in males. These findings suggest a significant role for puberty in structural brain development. © 2013. Published by Elsevier Inc. All rights reserved.
The influence of puberty on subcortical brain development
Goddings, Anne-Lise; Mills, Kathryn L.; Clasen, Liv S.; Giedd, Jay N.; Viner, Russell M.; Blakemore, Sarah-Jayne
2014-01-01
Puberty is characterized by hormonal, physical and psychological transformation. The human brain undergoes significant changes between childhood and adulthood, but little is known about how puberty influences its structural development. Using a longitudinal sample of 711 magnetic resonance imaging scans from 275 individuals aged 7–20 years, we examined how subcortical brain regions change in relation to puberty. Our regions of interest included the amygdala, hippocampus and corpus striatum including the nucleus accumbens (NA), caudate, putamen and globus pallidus (GP). Pubertal development was significantly related to structural volume in all six regions in both sexes. Pubertal development and age had both independent and interactive influences on volume for the amygdala, hippocampus and putamen in both sexes, and the caudate in females. There was an interactive puberty-by-age effect on volume for the NA and GP in both sexes, and the caudate in males. These findings suggest a significant role for puberty in structural brain development. PMID:24121203
NASA GRC Stirling Technology Development Overview
NASA Technical Reports Server (NTRS)
Thieme, Lanny G.; Schreiber, Jeffrey G.
2003-01-01
The Department of Energy, Lockheed Martin (LM), Stirling Technology Company, and NASA Glenn Research Center (GRC) are developing a high-efficiency Stirling Radioisotope Generator (SRG) for potential NASA Space Science missions. The SRG is being developed for multimission use, including providing spacecraft onboard electric power for NASA deep space missions and power for unmanned Mars rovers. NASA GRC is conducting an in- house supporting technology project to assist in developing the Stirling convertor for space qualification and mission implementation. Preparations are underway for a thermalhacuum system demonstration and unattended operation during endurance testing of the 55-We Technology Demonstration Convertors. Heater head life assessment efforts continue, including verification of the heater head brazing and heat treatment schedules and evaluation of any potential regenerator oxidation. Long-term magnet aging tests are continuing to characterize any possible aging in the strength or demagnetization resistance of the permanent magnets used in the linear alternator. Testing of the magnet/lamination epoxy bond for performance and lifetime characteristics is now underway. These efforts are expected to provide key inputs as the system integrator, LM, begins system development of the SRG. GRC is also developing advanced technology for Stirling convertors. Cleveland State University (CSU) is progressing toward a multi-dimensional Stirling computational fluid dynamics code, capable of modeling complete convertors. Validation efforts at both CSU and the University of Minnesota are complementing the code development. New efforts have been started this year on a lightweight convertor, advanced controllers, high-temperature materials, and an end-to-end system dynamics model. Performance and mass improvement goals have been established for second- and third-generation Stirling radioisotope power systems.
NASA Astrophysics Data System (ADS)
Diez-Jimenez, E.; Perez-Diaz, J. L.; Ferdeghini, C.; Canepa, F.; Bernini, C.; Cristache, C.; Sanchez-Garcia-Casarrubios, J.; Valiente-Blanco, I.; Ruiz-Navas, E. M.; Martínez-Rojas, J. A.
2018-04-01
An increasing number of cryogenic devices may benefit from the use of Nd2Fe14B permanent magnets. However, it is necessary to precisely know their behavior because magnetization varies significantly due to Spin Reorientation Transition. In this work, magnetic and morphological characterization of Nd2Fe14B commercial polycrystalline magnets with different quality grades from 5 to 300 K is provided. A set of magnets ranging from N35 to N52 quality have been analyzed. Mean grain dimension as well as material composition elements are provided. Higher quality magnets show smaller mean grain dimensions. Regarding cryogenic temperatures, the well know spin transition effect appears in all the magnets as expected, however, the transition temperature occurs at different temperatures in a range from 112 to 120 K which is lower than those obtained for single crystal samples. Moreover, the relative variation of the remanence from 300 to 5 K is lower than 4% while the maximum expected variation is in average 11%. As extra information, the same analyzes are provided for additional quality grades N40M, N40S, N40SH and N40UH.
Hugon, Cedric; D'Amico, Francesca; Aubert, Guy; Sakellariou, Dimitris
2010-07-01
Starting from general results of magnetostatics, we give fundamental considerations on the design and characterization of permanent magnets for NMR based on harmonic analysis and symmetry. We then propose a simple geometry that takes advantage of some of these considerations and discuss the practical aspects of the assembly of a real magnet based on this geometry, involving the characterization of its elements, the optimization of the layout and the correction of residual inhomogeneities due to material and geometry imperfections. We report with this low-cost, light-weight magnet (100 euros and 1.8 kg including the aluminum frame) a field of 120 mT (5.1 MHz proton) with a 10 ppm natural homogeneity over a sphere of 1.5 mm in diameter. Copyright (c) 2010 Elsevier Inc. All rights reserved.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Juarez, Aaron J.; Stassun, Keivan G.; Cargile, Phillip A.
2014-11-10
The lithium depletion boundary (LDB) is a robust method for accurately determining the ages of young clusters, but most pre-main-sequence models used to derive LDB ages do not include the effects of magnetic activity on stellar properties. In light of this, we present results from our spectroscopic study of the very-low-mass members of the southern open cluster Blanco 1 using the Gemini-North Telescope, program IDs: GN-2009B-Q-53 and GN-2010B-Q-96. We obtained Gemini Multi-Object Spectrograph spectra at intermediate resolution for cluster candidate members with I ≈ 13-20 mag. From our sample of 43 spectra, we find 14 probable cluster members by consideringmore » proximity to the cluster sequence in an I/I – K {sub s} color-magnitude diagram, agreement with the cluster's systemic radial velocity, and magnetic activity as a youth indicator. We systematically analyze the Hα and Li features and update the LDB age of Blanco 1 to be 126{sub −14}{sup +13} Myr. Our new LDB age for Blanco 1 shows remarkable coevality with the benchmark Pleiades open cluster. Using available empirical activity corrections, we investigate the effects of magnetic activity on the LDB age of Blanco 1. Accounting for activity, we infer a corrected LDB age of 114{sub −10}{sup +9} Myr. This work demonstrates the importance of accounting for magnetic activity on LDB inferred stellar ages, suggesting the need to reinvestigate previous LDB age determinations.« less
[Preparation and characterization of a polyvinylpyrrolidone water-based magnetic fluid].
Xie, Jian-feng; Zhang, Yang-de; Zeng, Zhao-wu; Wang, Xiao-li; Liu, Xing-yan; Zhou, Wei-hua
2008-03-01
To prepare a stable water-based magnetic fluid. A water-based magnetic fluid was prepared by addition of polyvinylpyrrolidone (PVP) as the coating agent for the magnetic particles. After preparation of Fe3O4 by co-precipitation method, PVP was added for its coating, followed by ultrasonic agitation and purification. The magnetic nanoparticles of homogeneously small size and water-based magnetic fluid were obtained, which had good dispersion in water with strong magnetism. PVP can be used as a surfactant to stabilize the magnetic fluid.
NASA Astrophysics Data System (ADS)
Ortega Nieto, A.; Fucugauchi, J. U.; Perez-Cruz, L. L.
2009-12-01
We present initial results of a petrological, magnetic and geochemical study of El Mimbral and La Lajilla sections that span the Cretaceous-Paleogene (K-Pg) boundary. K-Pg sections in northeastern Mexico have been intensively studied in past years, mainly because of their relationship to the Chicxulub crater in the Yucatan platform and for investigating the nature, origin, stratigraphic relations and age of the impact ejecta deposits. The K-Pg boundary is preserved in between hemipelagic marls and limestones of the Mendez (Maastrichtian) and Velasco (Paleocene) formations. The two sections are situated about 1000 km away from Chicxulub and K-Pg deposits are part of the proximal ejecta and the complex channelized siliciclastic units. We had separated the siliciclastic units into two parts, with a basal coarse poorly graded spherulitic bed some 0.2 to 1 m thick and a second part with several sandstone siltstone beds that have been grouped in various ways in previous studies. In the field, samples were collected across stratigraphic profiles for rock magnetic, petrological and geochemical analyses. Using field observations and analytical data, detailed columns for the two localities are prepared. Rock magnetic measurements include susceptibility, remanent and isothermal magnetization and remanent coercivity. Magnetic hysteresis loops and IRM and back-field demagnetization were measured for samples of spherulitic bed. X-ray fluorescence analyses on whole rock were complemented with previous data obtained for the Mimbral section by atomic absorption spectrometry and inductively coupled plasma mass spectrometry (including platinum group elements). Further detailed analysis concentrated in the ejecta material. The spherulitic bed is characterized by Fe-Mg rich chlorite and Si-Al-K rich glass spherules and carbonate accretionary lapilli spherules. The silicic component spherules are altered to calcite or chlorite-smectite, with some retaining glass cores. Spherules have been shown to contain Fe-Mg bubbly spherules, Fe-Ti-K schlieren and micrometer size metallic inclusions documenting a compositional range of mafic to intermediate rocks, which relate to the target stratigraphy in Yucatan with the thick surface carbonate platform sediments and the granitic and metamorphic basement. To further characterize the spherules and analyze the within- and between-sites diversity, some 60 individual spherules were separated from the two section beds. The spherules display different morphologies, surface colors and sizes, with vesiculated globular spherules, tear drop-like and ribbon and angular fragments. They show varying degrees of alteration and spherules often form aggregates, with welding and amalgamation. Fractured and deformed spherules appear almost altered. Results are discussed in terms of the K-Pg stratigraphy, nature and emplacement mechanism of ejecta deposits, alteration processes and implications/relationship with the Chicxulub impact.
Characterization of Magnetic Nanostructures Using Off-Axis Electron Holography
NASA Astrophysics Data System (ADS)
Zhang, Desai
This dissertation research has involved microscopic characterization of magnetic nanostructures using off-axis electron holography and Lorentz microscopy. The nanostructures investigated have included Co nanoparticles (NPs), Au/Fe/GaAs shell/core nanowires (NWs), carbon spirals with magnetic cores, magnetic nanopillars, Ni-Zn-Co spinel ferrite and CoFe/Pd multilayers. The studies have confirmed the capability of holography to describe the behavior of magnetic structures at the nanoscale. The phase changes caused by the fringing fields of chains consisting of Co NPs were measured and calculated. The difference between chains with different numbers of Co NPs followed the trend indicated by calculations. Holography studies of Au/Fe/GaAs NWs grown on (110) GaAs substrates with rotationally non-uniform coating confirmed that Fe was present in the shell and that the shell behaved as a bar magnet. No fringing field was observed from NWs with cylindrical coating grown on (111)B GaAs substrates. The most likely explanation is that magnetic fields are confined within the shells and form closed loops. The multiple-magnetic-domain structure of iron carbide cores in carbon spirals was imaged using phase maps of the fringing fields. The strength and range of this fringing field was insufficient for manipulating the carbon spirals with an external applied magnetic field. No magnetism was revealed for CoPd/Fe/CoPd magnetic nanopillars. Degaussing and MFM scans ruled out the possibility that saturated magnetization and sample preparation had degraded the anisotropy, and the magnetism, respectively. The results suggested that these nanopillars were not suitable as candidates for prototypical bit information storage devices. Observations of Ni-Zn-Co spinel ferrite thin films in plan-view geometry indicated a multigrain magnetic domain structure and the magnetic fields were oriented in-plane only with no preferred magnetization distribution. This domain structure helps explain this ferrite's high permeability at high resonance frequency, which is an unusual character. Perpendicular magnetic anisotropy (PMA) of CoFe/Pd multilayers was revealed using holography. Detailed microscopic characterization showed structural factors such as layer waviness and interdiffusion that could contribute to degradation of the PMA. However, these factors are overwhelmed by the dominant effect of the CoFe layer thickness, and can be ignored when considering magnetic domain structure.
The magnetic fields, ages, and original spin periods of millisecond pulsars
NASA Technical Reports Server (NTRS)
Camilo, F.; Thorsett, S. E.; Kulkarni, S. R.
1994-01-01
Accurate determination of the spin-down rates of millisecond pulsars requires consideration of the apparent acceleration of the pulsars due to their high transverse velocities. We show that for several nearby pulsars the neglect of this effect leads to substantial errors in inferred pulsar ages and magnetic fields. Two important ramifications follow. (1) The intrinsic magnetic field strengths of all millisecond pulsars lie below 5 x 10(exp 8) G, strengthening an earlier suggestion of a 'gap' between the magnetic field strengths of millisecond pulsars and of high-mass binary pulsars such as PSR B1913+16, which are thought to have been formed by mass transfer in low-mass and high-mass X-ray binaries, respectively. This result suggests that the magnetic field strengths of recycled pulsars are related to their formation and evolution in binary systems. (2) The corrected characteristic ages of several millisecond pulsars appear to be greater than the age of the Galactic disk. We reconcile this apparent paradox by suggesting that some millisecond pulsars were born with periods close to their current periods. This conclusion has important implications for the interpretation of the cooling ages of white dwarf companions, the birthrate discrepancy between millisecond pulsars and their X-ray binary progenitors, and the possible existence of a class of weakly magnetized (B much less than 10(exp 8)G), rapidly rotating neutron stars.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Vries, Wilke de; Doerenkamp, Carsten; Zeng, Zhaoyang
Inorganic–organic hybrid materials based on amorphous mesoporous silica containing organized nitroxide radicals within its mesopores have been prepared using the micellar self-assembly of TEOS solutions containing the nitroxide functionalized amphiphile (4-(N,N-dimethyl-N-hexadecylammonium)-2,2,6, 6-tetramethyl-piperidin-N-oxyl-iodide) (CAT-16). This template has been used both in its pure form and in various mixtures with cetyl trimethylammonium bromide (CTAB). The samples have been characterized by chemical analysis, N{sub 2} sorption studies, magnetic susceptibility measurements, and various spectroscopic methods. While electron paramagnetic resonance (EPR) spectra indicate that the strength of the intermolecular spin–spin interactions can be controlled via the CAT-16/CTAB ratio, nuclear magnetic resonance (NMR) data suggest thatmore » these interactions are too weak to facilitate cooperative magnetism. - Graphical abstract: The amphiphilic radical CAT-16 is used as a template for the synthesis of amorphous mesoporous silica. The resulting paramagnetic hybrid materials are characterized by BET, FTIR, NMR, EPR and magnetic susceptibility studies. - Highlights: • Amphiphilic CAT-16 as a template for mesoporous silica. • Comprehensive structural characterization by BET, FTIR; EPR and NMR. • Strength of radical-radical interactions tuable within CAT-16/CTAB mixtures.« less
Fleisher, Adam S.; Chen, Kewei; Quiroz, Yakeel T.; Jakimovich, Laura J.; Gomez, Madelyn Gutierrez; Langois, Carolyn M.; Langbaum, Jessica B. S.; Roontiva, Auttawut; Thiyyagura, Pradeep; Lee, Wendy; Ayutyanont, Napatkamon; Lopez, Liliana; Moreno, Sonia; Muñoz, Claudia; Tirado, Victoria; Acosta-Baena, Natalia; Fagan, Anne M.; Giraldo, Margarita; Garcia, Gloria; Huentelman, Matthew J.; Tariot, Pierre N.; Lopera, Francisco; Reiman, Eric M.
2015-01-01
IMPORTANCE Age-associated changes in brain imaging and fluid biomarkers are characterized and compared in presenilin 1 (PSEN1) E280A mutation carriers and noncarriers from the world’s largest known autosomal dominant Alzheimer disease (AD) kindred. OBJECTIVE To characterize and compare age-associated changes in brain imaging and fluid biomarkers in PSEN1 E280A mutation carriers and noncarriers. DESIGN, SETTING, AND PARTICIPANTS Cross-sectional measures of 18F-florbetapir positron emission tomography, 18F-fludeoxyglucose positron emission tomography, structural magnetic resonance imaging, cerebrospinal fluid (CSF), and plasma biomarkers of AD were assessed from 54 PSEN1 E280A kindred members (age range, 20-59 years). MAIN OUTCOMES AND MEASURES We used brain mapping algorithms to compare regional cerebral metabolic rates for glucose and gray matter volumes in cognitively unimpaired mutation carriers and noncarriers. We used regression analyses to characterize associations between age and the mean cortical to pontine 18F-florbetapir standard uptake value ratios, precuneus cerebral metabolic rates for glucose, hippocampal gray matter volume, CSF Aβ1-42, total tau and phosphorylated tau181, and plasma Aβ measurements. Age at onset of progressive biomarker changes that distinguish carriers from noncarriers was estimated using best-fitting regression models. RESULTS Compared with noncarriers, cognitively unimpaired mutation carriers had significantly lower precuneus cerebral metabolic rates for glucose, smaller hippocampal volume, lower CSF Aβ1-42, higher CSF total tau and phosphorylated tau181, and higher plasma Aβ1-42 measurements. Sequential changes in biomarkers were seen at age 20 years (95% CI, 14-24 years) for CSF Aβ1-42, age 16 years (95% CI, 11-24 years) for the mean cortical 18F-florbetapir standard uptake value ratio, age 15 years (95% CI, 10-24 years) for precuneus cerebral metabolic rate for glucose, age 15 years (95% CI, 7-20 years) for CSF total tau, age 13 years (95% CI, 8-19 years) for phosphorylated tau181, and age 6 years (95% CI, 1-10 years) for hippocampal volume, with cognitive decline up to 6 years before the kindred’s estimated median age of 44 years (95% CI, 43-45 years) at mild cognitive impairment diagnosis. No age-associated findings were seen in plasma Aβ1-42 or Aβ1-40. CONCLUSIONS AND RELEVANCE This cross-sectional study provides additional information about the course of different AD biomarkers in the preclinical and clinical stages of autosomal dominant AD. PMID:25580592
Characterization of CaMn2O4 By X-Ray Magnetic Linear Dichroism
NASA Astrophysics Data System (ADS)
Holroyd, Johnathon; Bhatkar, Harshawardhan; Arenholz, Elke; White, Ben; Neumeier, John; Idzerda, Yves
2008-05-01
Perovskite manganite such as LaxCa(1-x)MnO3 (LCMO) have recently drawn attention for their useful electronic and magnetic properties such as Colossal Magnetoresistance. It has been shown that under stress, LCMO thin films show changes in La and Ca concentrations near the interface. One potential impurity under La depleted conditions is antiferromagnetic CaMn2O4. In order to better understand the range of properties available within LCMO systems, it is important to be able to identify and characterize CaMn2O4 within LCMO thin films. X-ray absorption spectroscopy (XAS) and X-ray magnetic linear dichroism (XMLD) are well suited to this task due to their element specificity, sensitivity, and ability to characterize the measure the magnetic properties of antiferromagnetic systems. XAS and XMLD were measured on high quality single crystals of CaMn2O4. These spectra are distinguished from CaMnO3 and demonstrate antiferromagnetic structure.
NASA Astrophysics Data System (ADS)
Kempf, S.; Wegner, M.; Deeg, L.; Fleischmann, A.; Gastaldo, L.; Herrmann, F.; Richter, D.; Enss, C.
2017-06-01
We report on the design, fabrication and characterization of a 64 pixel metallic magnetic calorimeter array that is read out by an integrated, on-chip microwave SQUID multiplexer. Based on the results of our comprehensive device characterization we refined the state-of-the-art multiplexer model which assumes each associated non-hysteretic rf-SQUID to purely behave as a flux-dependent inductor. In particular, we include the capacitance and the subgap resistance of the Josephson junction as well as screening effects and parasitic mutual couplings between different coils that show up only when a superconducting flux transformer is attached to the SQUID input. Thanks to these modifications, we are able to explain the occurrence of a magnetic flux dependence of the internal quality factor of the microwave resonators as well as to accurately calculate the characteristic multiplexer parameters. When combining the refined multiplexer model with the thermodynamical description of a metallic magnetic calorimeter, we find a reasonable agreement between our measurements and predictions.
Design, Fabrication, Characterization and Modeling of Integrated Functional Materials
2011-10-01
the integration of multiple functionalities with desirable properties (thermal, electrical, magnetic, mechanical , optical, etc.), the connection to...mediated magnetic interactions in the nanocomposites. Our systematic studies on the underlying mechanism of magnetic interactions between graphene...or 3- nanocrystalline phases have been seen simultaneously within an amorphous matrix. The mechanism for induced magnetic anisotropy in these alloys
NASA Astrophysics Data System (ADS)
Rogers, Adam; Safi-Harb, Samar
2016-04-01
A wealth of X-ray and radio observations has revealed in the past decade a growing diversity of neutron stars (NSs) with properties spanning orders of magnitude in magnetic field strength and ages, and with emission processes explained by a range of mechanisms dictating their radiation properties. However, serious difficulties exist with the magneto-dipole model of isolated NS fields and their inferred ages, such as a large range of observed braking indices (n, with values often <3) and a mismatch between the NS and associated supernova remnant (SNR) ages. This problem arises primarily from the assumptions of a constant magnetic field with n = 3, and an initial spin period that is much smaller than the observed current period. It has been suggested that a solution to this problem involves magnetic field evolution, with some NSs having magnetic fields buried within the crust by accretion of fall-back supernova material following their birth. In this work, we explore a parametric phenomenological model for magnetic field growth that generalizes previous suggested field evolution functions, and apply it to a variety of NSs with both secure SNR associations and known ages. We explore the flexibility of the model by recovering the results of previous work on buried magnetic fields in young NSs. Our model fits suggest that apparently disparate classes of NSs may be related to one another through the time evolution of the magnetic field.
Mechanical properties of the in vivo adolescent human brain.
McIlvain, Grace; Schwarb, Hillary; Cohen, Neal J; Telzer, Eva H; Johnson, Curtis L
2018-06-10
Viscoelastic mechanical properties of the in vivo human brain, measured noninvasively with magnetic resonance elastography (MRE), have recently been shown to be affected by aging and neurological disease, as well as relate to performance on cognitive tasks in adults. The demonstrated sensitivity of brain mechanical properties to neural tissue integrity make them an attractive target for examining the developing brain; however, to date, MRE studies on children are lacking. In this work, we characterized global and regional brain stiffness and damping ratio in a sample of 40 adolescents aged 12-14 years, including the lobes of the cerebrum and subcortical gray matter structures. We also compared the properties of the adolescent brain to the healthy adult brain. Temporal and parietal cerebral lobes were softer in adolescents compared to adults. We found that of subcortical gray matter structures, the caudate and the putamen were significantly stiffer in adolescents, and that the hippocampus and amygdala were significantly less stiff than all other subcortical structures. This study provides the first detailed characterization of adolescent brain viscoelasticity and provides baseline data to be used in studying development and pathophysiology. Copyright © 2018 The Authors. Published by Elsevier Ltd.. All rights reserved.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Fang, Ming; Li, Xiuhua; Cui, Ping
2015-03-15
Two lanthanide-based frameworks: (Ln(phen)(NDA){sub 1.5}(H{sub 2}O)){sub n} (Ln=Gd(1), NDA=2,6-naphthalenedicarboxylate anion, phen=1,10-phenanthroline), and ([Dy(phen)(NDA){sub 1.5}]·0.5H{sub 2}NDA){sub n} (2) were structurally and magnetically characterized. Compound 1 exhibits 2D layer structure, belonging to the triclinic system with space group P−1, while compound 2 features a 3D framework with space group P−1. The magnetic studies revealed that ferromagnetic coupling existed between adjacent lanthanide ions in 1 and 2, and frequency-dependence out-of-phase signals in the measurement of alternate-current susceptibilities were observed for 2, albeit without reaching the characteristic maxima above 2 K, implying slow magnetic relaxation behavior in 2. After the application of a dcmore » field, good peak shapes of ac signal were obtained and got the energy barrier ΔE/k{sub B}=29 K and the pre-exponential factor τ{sub 0}=4.47×10{sup −7} s at 2000 Oe field; and when the dc field was in 5000 Oe, giving ΔE/k{sub B}=40 K and τ{sub 0}=2.82×10{sup −6}. - Graphical abstract: Two novel lanthanide-based frameworks 1 and 2 were structurally and magnetically characterized. The results revealed that ferromagnetic coupling exists between adjacent lanthanide ions in 1 and 2, and 2 displayed slow magnetic relaxation behavior with the energy barrier of 29 K. - Highlights: • Two lanthanide frameworks were synthesized and magnetically characterized. • The magnetism studies indicate slow magnetic relaxation behavior in 2. • Weak ferromagnetic coupling existing between adjacent lanthanide centers.« less
Submicron magnetic core conducting polypyrrole polymer shell: Preparation and characterization.
Tenório-Neto, Ernandes Taveira; Baraket, Abdoullatif; Kabbaj, Dounia; Zine, Nadia; Errachid, Abdelhamid; Fessi, Hatem; Kunita, Marcos Hiroiuqui; Elaissari, Abdelhamid
2016-04-01
Magnetic particles are of great interest in various biomedical applications, such as, sample preparation, in vitro biomedical diagnosis, and both in vivo diagnosis and therapy. For in vitro applications and especially in labs-on-a-chip, microfluidics, microsystems, or biosensors, the needed magnetic dispersion should answer various criteria, for instance, submicron size in order to avoid a rapid sedimentation rate, fast separations under an applied magnetic field, and appreciable colloidal stability (stable dispersion under shearing process). Then, the aim of this work was to prepare highly magnetic particles with a magnetic core and conducting polymer shell particles in order to be used not only as a carrier, but also for the in vitro detection step. The prepared magnetic seed dispersions were functionalized using pyrrole and pyrrole-2-carboxylic acid. The obtained core-shell particles were characterized in terms of particle size, size distribution, magnetization properties, FTIR analysis, surface morphology, chemical composition, and finally, the conducting property of those particles were evaluated by cyclic voltammetry. The obtained functional submicron highly magnetic particles are found to be conducting material bearing function carboxylic group on the surface. These promising conducting magnetic particles can be used for both transport and lab-on-a-chip detection. Copyright © 2015. Published by Elsevier B.V.
NASA Astrophysics Data System (ADS)
Fabiano, F.; Puliafito, V.; Calabrese, L.; Borsellino, C.; Bonaccorsi, L. M.; Giordano, A.; Fabiano, V.; Cordasco, G.
2016-04-01
Neodymium-iron-boron magnets are able to ensure a magnetic flux with high maximum energy product also at miniaturized size. In the past, due to their marked corrosion in saliva they were unsuccessfully implemented in orthodontic systems. Thereby, we propose a multi-layered organic-inorganic coating able to supply anticorrosion resistance, wear resistance and durability to the whole assembly. We evaluated the influence on the magnetic force of commercial nickel plated and silanized Nd-Fe-B during aging time in synthetic Fusayama saliva. Two magnets based-micromagnetic simulations were performed in order to analyze the magnetic field generated which is linked to the magnetic force. Our key results underline that the proposed hybrid coating does not affect the magnetic force of Nd-Fe-B magnets, moreover, preventing corrosion degradation in aggressive solution. Thus the limiting aspects avoiding the use of Nd-Fe-B magnets for orthodontic and prosthodontic applications can be overcome by using silane agents as surface coating.
Magnetic strength and corrosion of rare earth magnets.
Ahmad, Khalid A; Drummond, James L; Graber, Thomas; BeGole, Ellen
2006-09-01
Rare earth magnets have been used in orthodontics, but their corrosion tendency in the oral cavity limits long-term clinical application. The aim of this project was to evaluate several; magnet coatings and their effects on magnetic flux density. A total of 60 neodymium-iron-boron magnets divided into 6 equal groups--polytetrafluoroethylene-coated (PTFE), parylene-coated, and noncoated--were subjected to 4 weeks of aging in saline solution, ball milling, and corrosion testing. A significant decrease in magnet flux density was recorded after applying a protective layer of parylene, whereas a slight decrease was found after applying a protective layer of PTFE. After 4 weeks of aging, the coated magnets were superior to the noncoated magnets in retaining magnetism. The corrosion-behavior test showed no significant difference between the 2 types of coated magnets, and considerable amounts of iron-leached ions were seen in all groups. Throughout the processes of coating, soaking, ball milling, and corrosion testing, PTFE was a better coating material than parylene for preserving magnet flux density. However, corrosion testing showed significant metal leaching in all groups.
NASA Technical Reports Server (NTRS)
Raymond, C. A.; Labrecque, J. L.
1987-01-01
A model was proposed in which chemical remanent magnetization (CRM) acquired within the first 20 Ma of crustal evolution may account for 80 percent of the bulk natural remanent magnetization (NRM) of older basalts. The CRM of the crust is acquired as the original thermoremanent magnetization (TRM) is lost through low temperature alteration. The CRM intensity and direction are controlled by the post-emplacement polarity history. This model explains several independent observations concerning the magnetization of the oceanic crust. The model accounts for amplitude and skewness dicrepancies observed in both the intermediate wavelength satellite field and the short wavelength sea surface magnetic anomaly pattern. It also explains the decay of magnetization away from the spreading axis, and the enhanced magnetization of the Cretaceous Quiet Zones while predicting other systematic variations with age in the bulk magnetization of the oceanic crust. The model also explains discrepancies in the anomaly skewness parameter observed for anomalies of Cretaceous age. Further studies indicate varying rates of TRM decay in very young crust which depicts the advance of low temperature alteration through the magnetized layer.
2013-01-01
We report the synthesis and characterization of ferrite nanocrystals which exhibit high crystallinity and narrow size distributions. The three types of samples including Zn ferrite, Mn ferrite, and Mn-Zn ferrite were prepared via a non-aqueous nanoemulsion method. The structural, chemical, and magnetic properties of the nanocrystals are analyzed by transmission electron microscopy, X-ray diffraction, X-ray fluorescence, and physical property measurement system. The characterization indicates that the three types of ferrite nanocrystals were successfully produced, which show well-behaved magnetic properties, ferrimagnetism at 5 K and superparamagnetism at 300 K, respectively. In addition, the magnetization value of the ferrites increases with the increasing concentration of Mn. PMID:24344630
Diverse Application of Magnetic Resonance Imaging for Mouse Phenotyping
Wu, Yijen L.; Lo, Cecilia W.
2017-01-01
Small animal models, particularly mouse models, of human diseases are becoming an indispensable tool for biomedical research. Studies in animal models have provided important insights into the etiology of diseases and accelerated the development of therapeutic strategies. Detailed phenotypic characterization is essential, both for the development of such animal models and mechanistic studies into disease pathogenesis and testing the efficacy of experimental therapeutics. Magnetic Resonance Imaging (MRI) is a versatile and non-invasive imaging modality with excellent penetration depth, tissue coverage, and soft tissue contrast. MRI, being a multi-modal imaging modality, together with proven imaging protocols and availability of good contrast agents, is ideally suited for phenotyping mutant mouse models. Here we describe the applications of MRI for phenotyping structural birth defects involving the brain, heart, and kidney in mice. The versatility of MRI and its ease of use are well suited to meet the rapidly increasing demands for mouse phenotyping in the coming age of functional genomics. PMID:28544650
Suchy-Dicey, Astrid M.; Shibata, Dean; Best, Lyle G.; Verney, Steven P.; Longstreth, W.T.; Lee, Elisa T.; Okin, Peter M.; Devereux, Richard; O’Leary, Marcia; Ali, Tauqeer; Jensen, Paul N.; Muller, Clemma; Nelson, Lonnie A.; Rhoades, Everett; Madhyastha, Tara; Grabowski, Thomas J.; Beauchamp, Norman; Umans, Jason G.; Buchwald, Dedra
2016-01-01
The Cerebrovascular Disease and Its Consequences in American Indians (CDCAI) Study recruited surviving members of a 20-year, longitudinal, population-based cohort of American Indians focused on cardiovascular disease, its risk factors, and its consequences. The goal of CDCAI Study is to characterize the burden, risk factors, and manifestations of vascular brain injury identified on cranial magnetic resonance imaging (MRI). CDCAI Study investigators enrolled 1,033 participants aged 60 years and older from 11 American Indian communities and tribes in the Northern Plains, Southern Plains, and Southwestern U.S. In addition to cranial MRI performed according to standardized protocols, participants underwent extensive medical interview, clinical examination, neurocognitive testing, physical function evaluation, electrocardiogram, and provided blood and urine specimens. Participants also self-administered questionnaires covering demographics, quality of life, and medical history. This report describes the design, implementation, and some of the unique challenges of this study and data collection. PMID:27603047
NASA Astrophysics Data System (ADS)
de Paula, L. B.; Primo, F. L.; Jardim, D. R.; Morais, P. C.; Tedesco, A. C.
2012-04-01
A glioblastoma multiforme (GBM) is the highest grade glioma tumor (grade IV) and is the most malignant form of astrocytomas. Grade IV tumors, which are the most malignant and aggressive, affect people between the ages of 45 and 70 years. A GBM exhibits remarkable characteristics that include excessive proliferation, necrosis, genetic instability, and chemoresistance. Because of these characteristics, GBMs are difficult to treat and have a poor prognosis with a median survival of less than one year. New methods to achieve widespread distribution of therapeutic agents across infiltrative gliomas significantly improve brain tumor therapy. Photodynamic therapy (PDT) and hyperthermia (HPT) are well-established tumor therapies with minimal side effects while acting synergistically. This study introduces a new promising nanocarrier for the synergistic application of PDT and magnetic hyperthermia therapy against human glioma cell line T98 G, with cellular viability reduction down to as low as 17% compared with the control.
NASA Astrophysics Data System (ADS)
Saracco, Ginette; Moreau, Frédérique; Mathé, Pierre-Etienne; Hermitte, Daniel; Michel, Jean-Marie
2007-10-01
We have previously developed a method for characterizing and localizing `homogeneous' buried sources, from the measure of potential anomalies at a fixed height above ground (magnetic, electric and gravity). This method is based on potential theory and uses the properties of the Poisson kernel (real by definition) and the continuous wavelet theory. Here, we relax the assumption on sources and introduce a method that we call the `multiscale tomography'. Our approach is based on the harmonic extension of the observed magnetic field to produce a complex source by use of a complex Poisson kernel solution of the Laplace equation for complex potential field. A phase and modulus are defined. We show that the phase provides additional information on the total magnetic inclination and the structure of sources, while the modulus allows us to characterize its spatial location, depth and `effective degree'. This method is compared to the `complex dipolar tomography', extension of the Patella method that we previously developed. We applied both methods and a classical electrical resistivity tomography to detect and localize buried archaeological structures like antique ovens from magnetic measurements on the Fox-Amphoux site (France). The estimates are then compared with the results of excavations.
Hurley, Samuel A.; Samsonov, Alexey A.; Adluru, Nagesh; Hosseinbor, Ameer Pasha; Mossahebi, Pouria; Tromp, Do P.M.; Zakszewski, Elizabeth; Field, Aaron S.
2011-01-01
Abstract The image contrast in magnetic resonance imaging (MRI) is highly sensitive to several mechanisms that are modulated by the properties of the tissue environment. The degree and type of contrast weighting may be viewed as image filters that accentuate specific tissue properties. Maps of quantitative measures of these mechanisms, akin to microstructural/environmental-specific tissue stains, may be generated to characterize the MRI and physiological properties of biological tissues. In this article, three quantitative MRI (qMRI) methods for characterizing white matter (WM) microstructural properties are reviewed. All of these measures measure complementary aspects of how water interacts with the tissue environment. Diffusion MRI, including diffusion tensor imaging, characterizes the diffusion of water in the tissues and is sensitive to the microstructural density, spacing, and orientational organization of tissue membranes, including myelin. Magnetization transfer imaging characterizes the amount and degree of magnetization exchange between free water and macromolecules like proteins found in the myelin bilayers. Relaxometry measures the MRI relaxation constants T1 and T2, which in WM have a component associated with the water trapped in the myelin bilayers. The conduction of signals between distant brain regions occurs primarily through myelinated WM tracts; thus, these methods are potential indicators of pathology and structural connectivity in the brain. This article provides an overview of the qMRI stain mechanisms, acquisition and analysis strategies, and applications for these qMRI stains. PMID:22432902
Yao, Aihua; Chen, Qi; Ai, Fanrong; Wang, Deping; Huang, Wenhai
2011-10-01
The temperature-responsive magnetic composite particles were synthesized by emulsion-free polymerization of N-isopropylacrylamide (NIPAAm) and acrylamide (Am) in the presence of oleic acid-modified Fe(3)O(4) nanoparticles. The magnetic properties and heat generation ability of the composite particles were characterized. Furthermore, temperature and alternating magnetic field (AMF) triggered drug release behaviors of vitamin B(12)-loaded composite particles were also examined. It was found that composite particles enabled drug release to be controlled through temperature changes in the neighborhood of lower critical solution temperature. Continuous application of AMF resulted in an accelerated release of the loaded drug. On the other hand, intermittent AMF application to the composite particles resulted in an "on-off", stepwise release pattern. Longer release duration and larger overall release could be achieved by intermittent application of AMF as compared to continuous magnetic field. Such composite particles may be used for magnetic drug targeting followed by simultaneous hyperthermia and drug release.
Magnetic phase investigations on fluorine (F) doped LiFePO4
NASA Astrophysics Data System (ADS)
Radhamani, A. V.
2018-03-01
LiFePO4 (LFP) is a very promising cathode material for Li-ion batteries due to its high thermal stability, less toxicity and high theoretical capacity (170 mAh g-1). Anion doping, especially fluorine (F) at the oxygen site is one way to improve the low electronic conductivity of the material. In this line, fluorine doped LFP was prepared at different fluorine concentrations (1 to 40 mol%) to study the structural, spectroscopic and magnetic properties in view of the material property optimization for battery applications. The investigation of the magnetic properties was found to be successful for the determination of small amounts of magnetic impurities which were not noticeably observed from structural characterizations. Determination of conducting magnetic impurities has its own relevance in the current scenario of Li-ion based battery applications. Systematic characterization studies along with the implications of magnetic phases on the material activity of fluorine doped LiFePO4 nanoparticles will be discussed in detail.
Progress toward Synthesis and Characterization of Rare-Earth Nanoparticles
NASA Astrophysics Data System (ADS)
Romero, Dulce G.; Ho, Pei-Chun; Attar, Saeed; Margosan, Dennis
2010-03-01
Magnetic nanoparticles exhibit interesting phenomena, such as enhanced magnetization and reduced magnetic ordering temperature (i.e. superparamagnetism), which has technical applications in industry, including magnetic storage, magnetic imaging, and magnetic refrigeration. We used the inverse micelle technique to synthesize Gd and Nd nanoparticles given its potential to control the cluster size, amount of aggregation, and prevent oxidation of the rare-earth elements. Gd and Nd were reduced by NaBH4 from the chloride salt. The produced clusters were characterized by X-ray diffraction (XRD), scanning electron microscopy (SEM), and energy dispersive X-ray spectroscopy (EDX). The results from the XRD show that the majority of the peaks match those of the surfactant, DDAB. No peaks of Gd were observed due to excess surfactant or amorphous clusters. However, the results from the SEM and EDX indicate the presence of Gd and Nd in our clusters microscopically, and current synthesized samples contain impurities. We are using liquid-liquid extraction method to purify the sample, and the results will be discussed.
Magnetic Characterization of Micro Shutters for James Web Space Telescope (JWST)
NASA Technical Reports Server (NTRS)
Wasilewski, P. (Technical Monitor); Kletetschka, Gunther
2005-01-01
Summary of Research that was part of the grant: NASA NAG5 - 13405: Magnetic Characterization of Micro Shutters for James Web Space Telescope (JWST) Period: May 1 2003-October 31 2005 The above funding resulted in following major achievements related to microshutter system for JWST. 1. The original rectangular pattern of magnetic material was changed into magnetic striped pattern to prevent unnecessary twisting during the actuation. The Original geometry favored magnetic remanence vector being oriented along the longer side of the shutter and thus resulting torque caused out of plane twist. Stripe pattern minimizes the out of plane motion and thus prolongs the life-time of microshutter device. 2. We built a new magnetic system (magnetic rotisserie) allowing an accelerated life test of microshutters at various temperatures. This system identified that shutter are capable to withstand as many as several millions of actuating cycles. Our system also identified fabrication related features, like bowing with temperature, collisions with the frame due to misalignment, delaminating of the light shields due to uncontrolled voltage release and poorly fabricated light shields.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Ursache-Oprisan, Manuela; Foca-nici, Ecaterina; Cirlescu, Aurelian
2010-12-02
Sodium oleate was used as coating shell for magnetite, Zn ferrite and Co ferrite powders to stabilize them in the form of aqueous magnetic suspensions. The physical characterization was carried out by applying X-ray diffraction and magnetization measurements. Both crystallite size and magnetic core diameter ranged between 7 and 11 nm. The influence of magnetic nanoparticle suspensions (corresponding to magnetic nanoparticle levels of 10{sup -14}-10{sup -15}/cm{sup 3}) on sunflower seedlings was studied considering the changes in the photosynthesis pigment levels. Similar responses were obtained for magnetite and cobalt ferrite nanoparticle treatment consisting in the apparent inhibition of chlorophyll biosynthesis whilemore » for zinc ferrite nanoparticles some concentrations seemed to have stimulatory effects on the chlorophylls as well as on the carotene levels. But the chlorophyll ratio was diminished in the case of all three types of magnetic nanoparticles meaning their slight negative effect on the light harvesting complex II (LHC II) from the chloroplast membranes and consequently on the photosynthesis efficiency.« less
NASA Astrophysics Data System (ADS)
Ursache-Oprisan, Manuela; Foca-nici, Ecaterina; Cirlescu, Aurelian; Caltun, Ovidiu; Creanga, Dorina
2010-12-01
Sodium oleate was used as coating shell for magnetite, Zn ferrite and Co ferrite powders to stabilize them in the form of aqueous magnetic suspensions. The physical characterization was carried out by applying X-ray diffraction and magnetization measurements. Both crystallite size and magnetic core diameter ranged between 7 and 11 nm. The influence of magnetic nanoparticle suspensions (corresponding to magnetic nanoparticle levels of 10-14-10-15/cm3) on sunflower seedlings was studied considering the changes in the photosynthesis pigment levels. Similar responses were obtained for magnetite and cobalt ferrite nanoparticle treatment consisting in the apparent inhibition of chlorophyll biosynthesis while for zinc ferrite nanoparticles some concentrations seemed to have stimulatory effects on the chlorophylls as well as on the carotene levels. But the chlorophyll ratio was diminished in the case of all three types of magnetic nanoparticles meaning their slight negative effect on the light harvesting complex II (LHC II) from the chloroplast membranes and consequently on the photosynthesis efficiency.
Preparation and characterization of iron oxide magnetic nanoparticles functionalized by nisin.
Gruskiene, Ruta; Krivorotova, Tatjana; Staneviciene, Ramune; Ratautas, Dalius; Serviene, Elena; Sereikaite, Jolanta
2018-05-08
Nisin is a known bacteriocin approved as a food additive for food preservation. It exhibits a wide spectrum antimicrobial activity against Gram-positive bacteria. Iron oxide magnetic nanoparticles were synthesized and characterized by X-ray diffraction method. A main part of iron oxide nanoparticles was found to be maghemite though a small quantity of magnetite could also be present. Magnetic nanoparticles were stabilized by citric, ascorbic, gallic or glucuronic acid coating. Stable iron oxide magnetic nanoparticles were functionalized by nisin using a simple and low cost adsorption method. Nisin loading was confirmed by FT-IR spectra, thermogravimetric analysis, dynamic light scattering and atomic force microscopy methods. Nisin-loaded iron oxide magnetic nanoparticles were stable at least six weeks as judged by the measurements of zeta-potential and hydrodynamic diameter. The antimicrobial activity of nisin-loaded iron oxide magnetic nanoparticles was demonstrated toward Gram-positive bacteria. Functionalized nanoparticles could therefore find the application as antimicrobials in innovative and emerging technologies based on the magnetic field. Copyright © 2018 Elsevier B.V. All rights reserved.
NASA Astrophysics Data System (ADS)
Kılınç, Ersin
2016-03-01
In recent years, magnetic nanoparticles attained special interest in nanobiotechnology and nanomedicine due to their uniqe properties and biocompatibilities. From this perspective, hybride nanostructure composed from γ-Fe2O3 magnetic nanoparticle and carboxylated multi walled carbon nanotube was synthesized and characterized by FT-IR, VSM, SEM, HR-TEM and ICP-OES. Microscopy images showed that magnetic nanoparticles were nearly spherical structure that arranged on the axis of carboxylated MWCNT. Particle size was found lower than 10 nm. VSM results showed that the obtained magnetic nanoparticles presented superparamagnetic properties at room temperature. The magnetic saturation value was determined as 35.2 emu/g. It was used for the adsorption and controlled release of harmane, a potent tremor-producing neurotoxin. Maximum adsorption capacity was calculated as 151.5 mg/g from Langmuir isotherm. Concentration of harmane was determined by HPLC with fluorescence detection. The antimicrobial activity of synthesized magnetic nanoparticle was investigated against gram-negative and gram-positive bacteria. However, no activity was observed.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Calabrese, G.; Capineri, L., E-mail: lorenzo.capineri@unifi.it; Granato, M.
This paper describes the design of a system for the characterization of magnetic hysteresis behavior in soft ferrite magnetic cores. The proposed setup can test magnetic materials exciting them with controlled arbitrary magnetic field waveforms, including the capability of providing a DC bias, in a frequency bandwidth up to 500 kHz, with voltages up to 32 V peak-to-peak, and currents up to 10 A peak-to-peak. In order to have an accurate control of the magnetic field waveform, the system is based on a voltage controlled current source. The electronic design is described focusing on closed loop feedback stabilization and passivemore » components choice. The system has real-time hysteretic loop acquisition and visualization. The comparisons between measured hysteresis loops of sample magnetic materials and datasheet available ones are shown. Results showing frequency and thermal behavior of the hysteresis of a test sample prove the system capabilities. Moreover, the B-H loops obtained with a multiple waveforms excitation signal, including DC bias, are reported. The proposal is a low-cost and replicable solution for hysteresis characterization of magnetic materials used in power electronics.« less
Multiphase magnetic systems: Measurement and simulation
NASA Astrophysics Data System (ADS)
Cao, Yue; Ahmadzadeh, Mostafa; Xu, Ke; Dodrill, Brad; McCloy, John S.
2018-01-01
Multiphase magnetic systems are common in nature and are increasingly being recognized in technical applications. One characterization method which has shown great promise for determining separate and collective effects of multiphase magnetic systems is first order reversal curves (FORCs). Several examples are given of FORC patterns which provide distinguishing evidence of multiple phases. In parallel, a visualization method for understanding multiphase magnetic interaction is given, which allocates Preisach magnetic elements as an input "Preisach hysteron distribution pattern" to enable simulation of different "wasp-waisted" magnetic behaviors. These simulated systems allow reproduction of different major hysteresis loops and FORC patterns of real systems and parameterized theoretical systems. The experimental FORC measurements and FORC diagrams of four commercially obtained magnetic materials, particularly those sold as nanopowders, show that these materials are often not phase pure. They exhibit complex hysteresis behaviors that are not predictable based on relative phase fraction obtained by characterization methods such as diffraction. These multiphase materials, consisting of various fractions of BaFe12O19, ɛ-Fe2O3, and γ-Fe2O3, are discussed.
NASA Astrophysics Data System (ADS)
Kwon, Yong-Su; Choi, Kee-Bong; Lim, Hyungjun; Lee, Sunghwi; Lee, Jae-Jong
2018-06-01
Simple and versatile methodologies have been reported that customize the surface of superparamagnetic iron oxide (SPIO) nanoparticles and impart additional fluorescence capabilities to these contrast agents. Herein, we present the rational design, synthesis, characterization, and biological applications of a new magnetic-based fluorescent probe. The dual modality imaging protocol was developed by labeling fluorophore with alginate natural polymers that have excellent biocompatibility and biodegradability, and using gelification method to form nanocomposites containing SPIO. The formation of alginate-based fluorescent magnetic (AFM) nanoparticles was observed in spherical and elliptical forms with a diameter of less than 500 nm by a transmission electron microscope (TEM). The fluorescent wavelength band in the range of 560 nm was also confirmed in the UV–visible spectrophotometer. In this study, we demonstrate that the multi-tasking design of AFM nanoparticles provides an ideal platform for building balanced dual-image probes of magnetic resonance imaging and optical imaging.
Simioni, Andreza Ribeiro; Rodrigues, Marcilene M A; Primo, Fernando L; Morais, Paulo C; Tedesco, Antonio Claudio
2011-04-01
This study reports on the development and characterization of bovine serum albumin (BSA) nanospheres containing Silicon(IV) phthalocyanine (NzPc) and/or maghemite nanoparticles (MNP), the latter introduced via ionic magnetic fluid (MF). The nanosized BSA-loaded samples were designed for synergic application while combining Photodynamic Therapy and Hyperthermia. Incorporation of MNP in the albumin-based template, allowing full control of the magnetic content, was accomplished by adding a highly-stable ionic magnetic fluid sample to the albumin suspension, following heat denaturing. The material's evaluation was performed using Zeta potential measurements and scanning electron microscopy. The samples were characterized by steady-state techniques and time-resolved fluorescence. The in vitro assay, using human fibroblasts, revealed no cytotoxic effect in all samples investigated, demonstrating the potential of the tested system as a synergistic drug delivery system.
Design, fabrication, and characterization of a valveless magnetic travelling-wave micropump
NASA Astrophysics Data System (ADS)
Yu, Huawei; Ye, Weixiang; Zhang, Wei; Yue, Zhao; Liu, Guohua
2015-06-01
In this paper, we propose a valveless magnetic micropump for lab-on-a-chip and microfluidic applications. The micropump, based on polydimethylsiloxane (PDMS) and polymethylmethacrylate (PMMA), consists primarily of a saw-toothed microchannel, two substrates, and two integrated NdFeB permanent magnetic arrays. The travelling wave beneath the top wall of the elastic microchannel can be induced by the proper magnetic pole orientation arrangement of these magnetic arrays, and the liquid particles are then transported along with the travelling wave in the microchannel. Appropriate geometry of the saw-toothed microchannel was also studied for optimizing the performance of the micropump. Experimental characterization of the micropump has been performed in terms of the frequency response of the flow rate and backpressure. The results demonstrate that this micropump is capable of reliably generating a maximum flow rate of 342.4 μL min-1 and operating against a high backpressure of 1.67 kPa.
Near-Surface Plasma Characterization of the 12.5-kW NASA TDU1 Hall Thruster
NASA Technical Reports Server (NTRS)
Shastry, Rohit; Huang, Wensheng; Kamhawi, Hani
2015-01-01
To advance the state-of-the-art in Hall thruster technology, NASA is developing a 12.5-kW, high-specific-impulse, high-throughput thruster for the Solar Electric Propulsion Technology Demonstration Mission. In order to meet the demanding lifetime requirements of potential missions such as the Asteroid Redirect Robotic Mission, magnetic shielding was incorporated into the thruster design. Two units of the resulting thruster, called the Hall Effect Rocket with Magnetic Shielding (HERMeS), were fabricated and are presently being characterized. The first of these units, designated the Technology Development Unit 1 (TDU1), has undergone extensive performance and thermal characterization at NASA Glenn Research Center. A preliminary lifetime assessment was conducted by characterizing the degree of magnetic shielding within the thruster. This characterization was accomplished by placing eight flush-mounted Langmuir probes within each discharge channel wall and measuring the local plasma potential and electron temperature at various axial locations. Measured properties indicate a high degree of magnetic shielding across the throttle table, with plasma potential variations along each channel wall being less than or equal to 5 eV and electron temperatures being maintained at less than or equal to 5 eV, even at 800 V discharge voltage near the thruster exit plane. These properties indicate that ion impact energies within the HERMeS will not exceed 26 eV, which is below the expected sputtering threshold energy for boron nitride. Parametric studies that varied the facility backpressure and magnetic field strength at 300 V, 9.4 kW, illustrate that the plasma potential and electron temperature are insensitive to these parameters, with shielding being maintained at facility pressures 3X higher and magnetic field strengths 2.5X higher than nominal conditions. Overall, the preliminary lifetime assessment indicates a high degree of shielding within the HERMeS TDU1, effectively mitigating discharge channel erosion as a life-limiting mechanism.
Xia, Dunsheng; Wang, Bo; Yu, Ye; Jia, Jia; Nie, Yan; Wang, Xin; Xu, Shujing
2014-07-01
Various industrial processes and vehicular traffic result in harmful emissions containing both magnetic minerals and heavy metals. In this study, we investigated the levels of magnetic and heavy metal contamination of topsoils from Yinchuan city in northwestern China. The results demonstrate that magnetic mineral assemblages in the topsoil are dominated by pseudo-single domain (PSD) and multi-domain (MD) magnetite. The concentrations of anthropogenic heavy metals (Cr, Cu, Pb and Zn) and the magnetic properties of χlf, SIRM, χARM, and 'SOFT' and 'HARD' remanence are significantly correlated, suggesting that the magnetic minerals and heavy metals have common sources. Combined use of principal components and fuzzy cluster analysis of the magnetic and chemical data set indicates that the magnetic and geochemical properties of the particulates emitted from different sources vary significantly. Samples from university campus and residential areas are mainly affected by crustal material, with low concentrations of magnetic minerals and heavy metals, while industrial pollution sources are characterized by high concentrations of coarse magnetite and Cr, Cu, Pb and Zn. Traffic pollution is characterized by Pb and Zn, and magnetite. Magnetic measurements of soils are capable of differentiating sources of magnetic minerals and heavy metals from industrial processes, vehicle fleets and soil parent material. Copyright © 2014 Elsevier B.V. All rights reserved.
Quark–hadron phase structure, thermodynamics, and magnetization of QCD matter
NASA Astrophysics Data System (ADS)
Nasser Tawfik, Abdel; Magied Diab, Abdel; Hussein, M. T.
2018-05-01
The SU(3) Polyakov linear-sigma model (PLSM) is systematically implemented to characterize the quark-hadron phase structure and to determine various thermodynamic quantities and the magnetization of quantum chromodynamic (QCD) matter. Using mean-field approximation, the dependence of the chiral order parameter on a finite magnetic field is also calculated. Under a wide range of temperatures and magnetic field strengths, various thermodynamic quantities including trace anomaly, speed of sound squared, entropy density, and specific heat are presented, and some magnetic properties are described as well. Where available these results are compared to recent lattice QCD calculations. The temperature dependence of these quantities confirms our previous finding that the transition temperature is reduced with the increase in the magnetic field strength, i.e. QCD matter is characterized by an inverse magnetic catalysis. Furthermore, the temperature dependence of the magnetization showing that QCD matter has paramagnetic properties slightly below and far above the pseudo-critical temperature is confirmed as well. The excellent agreement with recent lattice calculations proves that our QCD-like approach (PLSM) seems to possess the correct degrees of freedom in both the hadronic and partonic phases and describes well the dynamics deriving confined hadrons to deconfined quark-gluon plasma.
Brain aging: Evaluation of pH using phosphorus magnetic resonance spectroscopy.
Cichocka, Monika; Kozub, Justyna; Urbanik, Andrzej
2018-02-02
Very important aspects of aging include age-related changes occurring in the brain. The aim of the present study was to identify the standard pH value in the entire brain volume using phosphorus magnetic resonance spectroscopy in healthy individuals of both sexes in different age groups, and then to determine whether there are differences in these values. A total of 65 individuals aged 20-32 years (mean age 24.5 ± 2.1 years, 31 women and 34 men) and 31 individuals aged 60-81 years (mean age 64.9 ± 5.5 years, 17 women and 14 men) were studied. The phosphorus magnetic resonance spectroscopy examination was carried out using a 1.5-T magnetic resonance system. The signal was acquired from the volume of interest that covered the whole brain. A vast majority of the examined individuals had slightly alkaline brain pH regardless of age. In the ≥20 years group, pH was 7.09 ± 0.11, and in the ≥60 years group, the average pH was 7.03 ± 0.05. This comparison of the pH identified in all the tested individuals shows a negative correlation of pH with age. The present findings might provide a valuable basis for further research into "healthy aging" as well as pathology in older adults. Geriatr Gerontol Int 2018; ••: ••-••. © 2018 Japan Geriatrics Society.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Malo, Lison; Doyon, René; Albert, Loïc
2014-09-01
Based on high-resolution optical spectra obtained with ESPaDOnS at Canada-France-Hawaii Telescope, we determine fundamental parameters (T {sub eff}, R, L {sub bol}, log g, and metallicity) for 59 candidate members of nearby young kinematic groups. The candidates were identified through the BANYAN Bayesian inference method of Malo et al., which takes into account the position, proper motion, magnitude, color, radial velocity, and parallax (when available) to establish a membership probability. The derived parameters are compared to Dartmouth magnetic evolutionary models and field stars with the goal of constraining the age of our candidates. We find that, in general, low-mass starsmore » in our sample are more luminous and have inflated radii compared to older stars, a trend expected for pre-main-sequence stars. The Dartmouth magnetic evolutionary models show a good fit to observations of field K and M stars, assuming a magnetic field strength of a few kG, as typically observed for cool stars. Using the low-mass members of the β Pictoris moving group, we have re-examined the age inconsistency problem between lithium depletion age and isochronal age (Hertzspring-Russell diagram). We find that the inclusion of the magnetic field in evolutionary models increases the isochronal age estimates for the K5V-M5V stars. Using these models and field strengths, we derive an average isochronal age between 15 and 28 Myr and we confirm a clear lithium depletion boundary from which an age of 26 ± 3 Myr is derived, consistent with previous age estimates based on this method.« less
Magnetic susceptibility induced echo time shifts: Is there a bias in age-related fMRI studies?
Ngo, Giang-Chau; Wong, Chelsea N.; Guo, Steve; Paine, Thomas; Kramer, Arthur F.; Sutton, Bradley P.
2016-01-01
Purpose To evaluate the potential for bias in functional MRI (fMRI) aging studies resulting from age-related differences in magnetic field distributions which can impact echo time and functional contrast. Materials and Methods Magnetic field maps were taken on 31 younger adults (age: 22 ± 2.9 years) and 46 older adults (age: 66 ± 4.5 years) on a 3 T scanner. Using the spatial gradients of the magnetic field map for each participant, an echo planar imaging (EPI) trajectory was simulated. The effective echo time, time at which the k-space trajectory is the closest to the center of k-space, was calculated. This was used to examine both within-subject and across-age-group differences in the effective echo time maps. The Blood Oxygenation Level Dependent (BOLD) percent signal change resulting from those echo time shifts was also calculated to determine their impact on fMRI aging studies. Result For a single subject, the effective echo time varied as much as ± 5 ms across the brain. An unpaired t-test between the effective echo time across age group resulted in significant differences in several regions of the brain (p<0.01). The difference in echo time was only approximately 1 ms, however which is not expected to have an important impact on BOLD fMRI percent signal change (< 4%). Conclusion Susceptibility-induced magnetic field gradients induce local echo time shifts in gradient echo fMRI images, which can cause variable BOLD sensitivity across the brain. However, the age-related differences in BOLD signal are expected to be small for an fMRI study at 3 T. PMID:27299727
Lockhart, Mark E.; Bates, G. Wright; Morgan, Desiree E.; Beasley, Timothy M.; Richter, Holly E.
2017-01-01
Introduction and Hypothesis To prospectively characterize dynamic pelvic 3Tesla magnetic resonance imaging (dp3T MRI) findings in nulligravida women and characterize changes 6 months after delivery in the same woman. Methods In this prospective study, nulligravida women seeking assisted reproductive technology for pregnancy were recruited. After physical examination by Pelvic Organ Prolapse Quantification (POP-Q), Brinks assessment and measures including the Pelvic Floor Distress Inventory-20 and Pelvic Floor Impact Questionnaire-7, pre-pregnancy dp3T MRI at rest, with strain, and evacuation were performed. Assessments were repeated ≥6 months postpartum. Analysis included Welch and paired t-tests for continuous variables, Fisher’s Exact Test for differences in categorical outcomes, and paired t-tests for postpartum symptoms. Results Nineteen subjects (mean±SD age, 31±5 years) completed baseline clinical and dp3T MRI studies, 15 delivered and 10 (30.5±3 years) completed pre-pregnancy and post-delivery clinical and dp3T MRI assessments. There were no significant changes in scores of validated questionnaires (all p>0.05) or on POP-Q measures post-delivery. Two (20%) subjects without pre-pregnancy levator tears had tears on MRI post-delivery. MRI measures of pelvic organ descent were increased post-delivery. Seventeen pelvic soft tissue parameters increased by greater than 10% post-delivery including 5/70 (7.1%), 17/110 (15.5%), and 50/110 (45.5%) values exceeding thresholds at rest, strain, and evacuation, respectively. Conclusions Dynamic pelvic 3T Magnetic Resonance Imaging detected levator tears and increased pelvic organ descent, which can be directly attributed to pregnancy and delivery. PMID:28871385
Rotordynamic Characterization of a Hybrid Superconductor Magnet Bearing
NASA Technical Reports Server (NTRS)
Ma, Ki B.; Xia, Zule H.; Cooley, Rodger; Fowler, Clay; Chu, Wei-Kan
1996-01-01
A hybrid superconductor magnet bearing uses magnetic forces between permanent magnets to provide lift and the flux pinning force between permanent magnets and superconductors to stabilize against instabilities intrinsic to the magnetic force between magnets. We have constructed a prototype kinetic energy storage system, using a hybrid superconductor magnet bearing to support a 42 lb. flywheel at the center. With five sensors on the periphery of the flywheel, we have monitored the position and attitude of the flywheel during its spin down. The results indicate low values of stiffnesses for the bearing. The implications of this and other consequences will be discussed.
Eye Growth in Term- And Preterm-Born Eyes Modeled From Magnetic Resonance Images
Munro, Robert J.; Fulton, Anne B.; Chui, Toco Y. P.; Moskowitz, Anne; Ramamirtham, Ramkumar; Hansen, Ronald M.; Prabhu, Sanjay P.; Akula, James D.
2015-01-01
Purpose. We generated a model of eye growth and tested it against an eye known to develop abnormally, one with a history of retinopathy of prematurity (ROP). Methods. We reviewed extant magnetic resonance images (MRIs) from term and preterm-born patients for suitable images (n = 129). We binned subjects for analysis based upon postmenstrual age at birth (in weeks) and ROP history (“Term” ≥ 37, “Premature” ≤ 32 with no ROP, “ROP” ≤ 32 with ROP). We measured the axial positions and curvatures of the cornea, anterior and posterior lens, and inner retinal surface. We fit anterior chamber depth (ACD), posterior segment depth (PSD), axial length (AL), and corneal and lenticular curvatures with logistic growth curves that we then evaluated for significant differences. We also measured the length of rays from the centroid to the surface of the eye at 5° intervals, and described the length versus age relationship of each ray, Lray(x), using the same logistic growth curve. We determined the rate of ray elongation, Eray(x), from Lray dy/dx. Then, we estimated the scleral growth that accounted for Eray(x), G(x), at every age and position. Results. Relative to Term, development of ACD, PSD, AL, and corneal and lenticular curvatures was delayed in ROP eyes, but not Premature eyes. In Term infants, G(x) was fast and predominantly equatorial; in age-matched ROP eyes, maximal G(x) was offset by approximately 90°. Conclusions. We produced a model of normal eye growth in term-born subjects. Relative to normal, the ROP eye is characterized by delayed, abnormal growth. PMID:26024095
Gravity and magnetic modeling of granitic bodies in Central Portugal
NASA Astrophysics Data System (ADS)
Machadinho, Ana; Figueiredo, Fernando; Pereira, Alcides
2015-04-01
A better understanding of the subsurface geometry of the granitic bodies in Central Portugal is the main goal of this work. The results are also relevant for the assessment of the geothermal potential of the same region. The study area is located in the Central Iberian Zone where the Beiras granite batholith outcrops. These variscan granitoids were emplaced into the "Complexo Xisto-Grauváquico" (CXG), a thick and monotonous megasequences of metapelites and metagreywackes. This metasedimentary sequence is affected by the Variscan deformation phases and a late Proterozoic to Cambrian age has been generally assumed for this rocks. The granitoids in the region are attributed to the magmatic activity associated to the post-collisional stages of the Variscan orogeny during the D3 stage. The granitic bodies in the study area are considered syn-D3 and late to post-D3. To achieve the goal of the research, magnetic and gravimetric surveys where performed in order to obtain the Bouguer and magnetic anomalies. All the standard corrections were applied to the gravimetric and magnetic data. Considering and integrating all the available geological data and physical proprieties (density and magnetic susceptibility) the mentioned potential fields were simultaneously modeled. In this way it was possible to characterize the subsurface geometry of the granitic bodies in the studied region. The modeling results show that the regional tectonic setting controls the geometry of the granitic bodies as well as the structure of the host CXG metasedimentary sequence. Through the modeling of the potential field the overall geometry, average and maximum depths of the granitic bodies in the study area was obtained. Some late to post-D3 plutons outcrop in spatial continuity and as they have similar ages, a common feeding zone is assumed as the most likely scenario. The sin-D3 pluton is more abrupt and vertical, suggesting the presence of a fault contact with the late-D3 pluton. According to the developed study the areas with higher geothermal potential for EGS applications are located over the sectors where the granitic bodies have the greater thickness.
Rock magnetic and paleomagnetic study of the Keurusselkä impact structure, central Finland
NASA Astrophysics Data System (ADS)
Raiskila, Selen; Salminen, Johanna; Elbra, Tiiu; Pesonen, Lauri J.
2011-11-01
There are 31 proven impact structures in Fennoscandia—one of the most densely crater-populated areas of the Earth. The recently discovered Keurusselkä impact structure (62°08' N, 24°37' E) is located within the Central Finland Granitoid Complex, which formed 1890-1860 Ma ago during the Svecofennian orogeny. It is a deeply eroded complex crater that yields in situ shatter cones with evidence of shock metamorphism, e.g., planar deformation features in quartz. New petrophysical and rock magnetic results of shocked and unshocked target rocks of various lithologies combined with paleomagnetic studies are presented. The suggested central uplift with shatter cones is characterized by increased magnetization and susceptibility. The presence of magnetite and pyrrhotite was observed as carriers for the remanent magnetization. Four different remanent magnetization directions were isolated: (1) a characteristic Svecofennian target rock component A with a mean direction of D = 334.8°, I = 45.6°, α95 = 14.9° yielding a pole (Plat = 51.1°, Plon = 241.9°, A95 = 15.1°), (2) component B, D = 42.4°, I = 64.1°, α95 = 8.4° yielding a pole (Plat = 61.0°, Plon = 129.1°, A95 = 10.6°), (3) component C (D = 159.5°, I = 65.4°, α95 = 10.7°) yielding a pole (Plat = 21.0°, Plon = 39.3°, A95 = 15.6°), and (4) component E (D = 275.5°, I = 62.0°, α95 = 14.4°) yielding a pole (Plat = 39.7°, Plon = 314.3°, A95 = 19.7°). Components C and E are considered much younger, possibly Neoproterozoic overprints, compared with the components A and B. The pole of component B corresponds with the 1120 Ma pole of Salla diabase dyke and is in agreement with the 40Ar/39Ar age of 1140 Ma from a pseudotachylitic breccia vein in a central part of the structure. Therefore, component B could be related to the impact, and thus represent the impact age.
NASA Astrophysics Data System (ADS)
Ramlan; Muljadi; Sardjono, Priyo; Gulo, Fakhili; Setiabudidaya, Dedi
2017-07-01
Permanent magnet of Barium hexa Ferrite with formula BaFe12O19 has been made by metallurgy powder method from raw materials : Barium carbonate (BaCO3 E-merck) and Iron Oxide (Fe2O3 from mill scale). Both of raw materials have been mixed with stoichiometry composition by using a ball mill for 24 hours. The fine powder obtained from milling process was formed by using a hydraulic press at pressure 50 MPa and continued with sintering process. The sintering temperature was varied : 1150°C, 1200°C, 1250°C and 1300°C with holding time for 1 hour. The sintered samples were characterized such as : physical properties (bulk density, porosity and shrinkage), magnetic properties (flux density, remanence, coercivity and magnetic saturation) by using VSM and crystal structure by using XRD. According characterization results show that the crystal structure of BaFe12O19 does not change after sintering process, but the grain size tends to increase. The optimum condition is achieved at temperature 1250°C, and at this condition, the sample has characterization such as : bulk density = 4.35 g/cm3, porosity = 1.03% and firing shrinkage = 11.63%, flux density = 681.1 Gauss, remanence (σr) = 20.78 emu/g, coercivity (Hc) = 2058 Oe and magnetic saturation (σs) 45.16 emu/g.
The magnetic signature of ultramafic-hosted hydrothermal systems (Invited)
NASA Astrophysics Data System (ADS)
Szitkar, F.; Dyment, J.; Honsho, C.; Horen, H.; Fouquet, Y.
2013-12-01
While the magnetic response of basalt-hosted hydrothermal sites is well known, that of ultramafic-hosted hydrothermal sites (UMHS) remains poorly documented. Here we present the magnetic signature of three of the six UMHS investigated to date on the Mid-Atlantic Ridge, i.e. sites Rainbow, Ashadze (1 and 2), and Logachev. Two magnetic signatures are observed. Sites Rainbow and Ashadze 1 are both characterized by a positive reduced-to-the-pole magnetic anomaly, i.e. a positive magnetization contrast. Conversely, sites Ashadze 2 and Logachev do not exhibit any clear magnetic signature. Rock-magnetic measurements on samples from site Rainbow reveal a strong magnetization (~30 A/m adding induced and remanent contributions) borne by sulfide-impregnated serpentinites; the magnetic carrier being magnetite. This observation can be explained by three (non exclusive) processes: (1) higher temperature serpentinization at the site resulting in the formation of more abundant / more strongly magnetized magnetite; (2) the reducing hydrothermal fluid protecting magnetite at the site from the oxidation which otherwise affects magnetite in contact with seawater; and (3) the formation of primary (hydrothermal) magnetite. We apply a new inversion method developed by Honsho et al. (2012) to the high-resolution magnetic anomalies acquired 10 m above seafloor at sites Rainbow and Ashadze 1. This method uses the Akaike Bayesian Information Criterion (ABIC) and takes full advantage of the near-seafloor measurements, avoiding the upward-continuation (i.e. loss of resolution) of other inversion schemes. This inversion reveals a difference in the intensity of equivalent magnetization obtained assuming a 100 m thick magnetic layer, ~30 A/m at site Rainbow and only 8A/m at site Ashadze, suggesting a thinner or less magnetized source for the latter. Hydrothermal sites at Ashadze 2 and Logachev are much smaller (of the order of 10 m) than the previous ones (several 100 m). These sites, known as "smoking craters", are episodically affected by explosions. The lack of any significant magnetic signature is explained by their small size and the random orientation of the (possibly magnetized) blocks spread out from the explosions. While basalt-hosted sites are characterized by a lack of magnetization, UMHS are characterized by a positive magnetization contrast, ranging from very strong (at site Rainbow) to negligible (at sites Ashadze 2 and Logachev) as a function of parameters such as the size of the deposit, the mode of discharge, and the fluid temperature, which effects remains to be carefully investigated.
Swift, Andrew J; Rajaram, Smitha; Campbell, Michael J; Hurdman, Judith; Thomas, Steve; Capener, Dave; Elliot, Charlie; Condliffe, Robin; Wild, Jim M; Kiely, David G
2014-01-01
There are limited data on the prognostic value of cardiovascular magnetic resonance measurements in idiopathic pulmonary arterial hypertension, with no studies investigating the impact of correction of cardiovascular magnetic resonance indices for age and sex on prognostic value. Consecutive patients with idiopathic pulmonary arterial hypertension underwent cardiovascular magnetic resonance imaging at 1.5T. Steady-state free precession cardiac volumes and mass measurements were corrected for age, sex, and body surface area according to reference data and prognostic significance assessed. A total of 80 patients with idiopathic pulmonary arterial hypertension were identified, and 23 patients died during the mean follow-up of 32±14 months. Corrected for age, sex, and body surface area, right ventricular end-systolic volume (P=0.004) strongly predicted mortality, independent of World Health Organization functional class, mean right atrial pressure, cardiac index, and mixed venous oxygen saturations. Consideration should be given to correcting cardiovascular magnetic resonance measures for age, sex, and body surface area, particularly given the changing demographics of patients with idiopathic pulmonary arterial hypertension. Corrected right ventricular end-systolic volume is a strong prognostic marker in idiopathic pulmonary arterial hypertension, independent of invasively derived measurements, mean right atrial pressure cardiac index, and mixed venous oxygen saturations.
Susac syndrome: the first case report in Peru.
Rivadeneira-Sotelo, Carolina; Meza Vega, María; Segura-Chávez, Darwin; Castro-Suarez, Sheila
2017-08-30
Susac Syndrome is a rare entity, characterized by a triad of subacute encephalopathy, retinal artery occlusion and sensorineural hearing loss. It is more common in women and the age of onset fluctuates between 9-58 years of age. The pathogenesis is presented as microangiopathic changes at the cerebral, retinal and cochlear levels associated with an autoimmune mechanism. We present the case of a 31-year-old woman who started with a diffuse headache, puerile behavior, bradylalia and somnolence. As the disease progressed, she had auditory deficit and arterial obstruction of the right temporal retinal branch in retinal fluorescein angiography. Brain magnetic resonance showed rounded hyperintense lesions in the corpus callosum, periventricular region and cerebellum. This is the first reported case of Susac Syndrome in Peru, presented with the classic triad, which is an infrequent presentation. However, cases that show incomplete forms should be evaluated in a timely manner to initiate timely treatment and avoid irreversible consequences.
Development of sensitivity versus specificity for print in the visual word form area.
Centanni, Tracy M; King, Livia W; Eddy, Marianna D; Whitfield-Gabrieli, Susan; Gabrieli, John D E
2017-07-01
An area near the left lateral occipito-temporal sulcus that responds preferentially to print has been designated as the visual word form area (VWFA). Research suggests that specialization in this brain region increases as reading expertise is achieved. Here we aimed to characterize that development in terms of sensitivity (response to printed words relative to non-linguistic faces) versus specificity (response to printed words versus line drawings of nameable objects) in typically reading children ages 7-14 versus young adults as measured by functional magnetic resonance imaging (fMRI). Relative to adults, children displayed equivalent sensitivity but reduced specificity. These findings suggest that sensitivity for print relative to non-linguistic stimuli develops relatively early in the VWFA in the course of reading development, but that specificity for printed words in VWFA is still developing through at least age 14. Copyright © 2017 Elsevier Inc. All rights reserved.
Magnetic and electric deflector spectrometers for ion emission analysis from laser generated plasma
NASA Astrophysics Data System (ADS)
Torrisi, Lorenzo; Costa, Giuseppe; Ceccio, Giovanni; Cannavò, Antonino; Restuccia, Nancy; Cutroneo, Mariapompea
2018-01-01
The pulsed laser-generated plasma in vacuum and at low and high intensities can be characterized using different physical diagnostics. The charge particles emission can be characterized using magnetic, electric and magnet-electrical spectrometers. Such on-line techniques are often based on time-of-flight (TOF) measurements. A 90° electric deflection system is employed as ion energy analyzer (IEA) acting as a filter of the mass-to-charge ratio of emitted ions towards a secondary electron multiplier. It determines the ion energy and charge state distributions. The measure of the ion and electron currents as a function of the mass-to-charge ratio can be also determined by a magnetic deflector spectrometer, using a magnetic field of the order of 0.35 T, orthogonal to the ion incident direction, and an array of little ion collectors (IC) at different angles. A Thomson parabola spectrometer, employing gaf-chromix as detector, permits to be employed for ion mass, energy and charge state recognition. Mass quadrupole spectrometry, based on radiofrequency electric field oscillations, can be employed to characterize the plasma ion emission. Measurements performed on plasma produced by different lasers, irradiation conditions and targets are presented and discussed. Complementary measurements, based on mass and optical spectroscopy, semiconductor detectors, fast CCD camera and Langmuir probes are also employed for the full plasma characterization. Simulation programs, such as SRIM, SREM, and COMSOL are employed for the charge particle recognition.
Innovative techniques to analyze time series of geomagnetic activity indices
NASA Astrophysics Data System (ADS)
Balasis, Georgios; Papadimitriou, Constantinos; Daglis, Ioannis A.; Potirakis, Stelios M.; Eftaxias, Konstantinos
2016-04-01
Magnetic storms are undoubtedly among the most important phenomena in space physics and also a central subject of space weather. The non-extensive Tsallis entropy has been recently introduced, as an effective complexity measure for the analysis of the geomagnetic activity Dst index. The Tsallis entropy sensitively shows the complexity dissimilarity among different "physiological" (normal) and "pathological" states (intense magnetic storms). More precisely, the Tsallis entropy implies the emergence of two distinct patterns: (i) a pattern associated with the intense magnetic storms, which is characterized by a higher degree of organization, and (ii) a pattern associated with normal periods, which is characterized by a lower degree of organization. Other entropy measures such as Block Entropy, T-Complexity, Approximate Entropy, Sample Entropy and Fuzzy Entropy verify the above mentioned result. Importantly, the wavelet spectral analysis in terms of Hurst exponent, H, also shows the existence of two different patterns: (i) a pattern associated with the intense magnetic storms, which is characterized by a fractional Brownian persistent behavior (ii) a pattern associated with normal periods, which is characterized by a fractional Brownian anti-persistent behavior. Finally, we observe universality in the magnetic storm and earthquake dynamics, on a basis of a modified form of the Gutenberg-Richter law for the Tsallis statistics. This finding suggests a common approach to the interpretation of both phenomena in terms of the same driving physical mechanism. Signatures of discrete scale invariance in Dst time series further supports the aforementioned proposal.
Magnetic and geochemical characterization of iron pollution in subway dusts in Shanghai, China
NASA Astrophysics Data System (ADS)
Zhang, Weiguo; Jiang, Huimin; Dong, Chenyin; Yan, Qun; Yu, Lizhong; Yu, Yang
2011-06-01
Dust samples collected from subway platforms in Shanghai, China, have been examined using magnetic measurements and geochemical analysis. Our results indicate that the Shanghai subway platform dusts have extremely strong magnetic signatures. These results, combined with X-ray diffraction analysis and scanning and transmission electron microscope examinations, indicate that the magnetic mineralogy of the dust is dominated by iron scraps due to wheel-rail mechanical abrasion and spherules rich in magnetite from fossil fuel combustion. Although the magnetic particles are primarily micrometer sized, fine submicron magnetic grains are also evident in the dust. The underground platform dusts have a much higher iron flake abundance and magnetic susceptibility than those from aboveground platforms because the latter ones are diluted by inputs of magnetically weaker ambient aerosols with a higher proportion of magnetite spherules. Geochemical analysis indicates that underground platform dusts have elevated Fe and Mn, but lower Al and Ti contents relative to aboveground subway dust. This is consistent with the closed nature of underground platforms, which therefore reduces exposure to soil-derived dust. Since the adverse environmental effects of subway particles may be linked to higher contents of iron and other metals, our results demonstrate that magnetic measurements provide a novel and effective approach for characterizing iron mineralogy and grain size in subway dusts.
Strickland, N M; Hoffmann, C; Wimbush, S C
2014-11-01
A cryogenic electrical transport measurement system is described that is particularly designed to meet the requirements for routine and effective characterization of commercial second generation high-temperature superconducting (HTS) wires in the form of coated conductors based on YBa2Cu3O7. Specific design parameters include a base temperature of 20 K, an applied magnetic field capability of 8 T (provided by a HTS split-coil magnet), and a measurement current capacity approaching 1 kA. The system accommodates samples up to 12 mm in width (the widest conductor size presently commercially available) and 40 mm long, although this is not a limiting size. The sample is able to be rotated freely with respect to the magnetic field direction about an axis parallel to the current flow, producing field angle variations in the standard maximum Lorentz force configuration. The system is completely free of liquid cryogens for both sample cooling and magnet cool-down and operation. Software enables the system to conduct a full characterization of the temperature, magnetic field, and field angle dependence of the critical current of a sample without any user interaction. The system has successfully been used to measure a wide range of experimental and commercially-available superconducting wire samples sourced from different manufacturers across the full range of operating conditions. The system encapsulates significant advances in HTS magnet design and efficient cryogen-free cooling technologies together with the capability for routine and automated high-current electrical transport measurements at cryogenic temperatures. It will be of interest to both research scientists investigating superconductor behavior and commercial wire manufacturers seeking to accurately characterize the performance of their product under all desired operating conditions.
Magnetic microscopy/metrology potential of metamaterials using nanosized spherical particle arrays
NASA Astrophysics Data System (ADS)
Eason, Kwaku; Luk'yanchuk, Boris; Zhou, Yi; Miroshnichenko, Andrey E.; Kivshar, Yuri S.
2011-12-01
Techniques for imaging and characterizing magnetic samples have been widely used in many areas of research involving magnetic materials. Nowadays, magnetic microscopy techniques play a critical role in characterizing magnetic thin film structures. In considering the various techniques, optical techniques offer some unique advantages over alternative techniques (e.g. MFM), as they are least affected by magnetic noise and, for the same underlying reasons, have also proven to be more suitable for "high speed" magnetization measurements of magnetization dynamics, which are increasingly important in many of today's research scopes. At the same time, development of metamaterials are opening the doors for newly behaving materials, such as those demonstrating negative refractive index, potentially useful in a variety of applications, such as imaging. Metamaterials deploying arrays of silicon particles, and even alternating silicon particles and split ring resonators have recently been shown to demonstrate interesting behavior, such as negative magnetic susceptibility and large resonant peaks in the Terahertz regime. Such high frequencies offer the potential bandwidth of extraordinarily fast dynamics, which are increasingly being generated in magnetic materials, for example, in optically-induced demagnetization and all-optical magnetic recording. Here, initial investigations toward ultra high-speed imaging and/or information extraction from magnetic samples is discussed considering metamaterials deploying mainly spherical particle arrays. In addition to the frequency spectrums of the system, the response of the system to external magnetic fields and background permeability changes due to external fields are investigated. Our results suggest a significant potential of metamaterials for use in probing information from magnetic materials.
Magnetic characterization of isolated candidate vertebrate magnetoreceptor cells
Eder, Stephan H.K.; Cadiou, Hervé; Muhamad, Airina; McNaughton, Peter A.; Kirschvink, Joseph L.; Winklhofer, Michael
2012-01-01
Over the past 50 y, behavioral experiments have produced a large body of evidence for the existence of a magnetic sense in a wide range of animals. However, the underlying sensory physiology remains poorly understood due to the elusiveness of the magnetosensory structures. Here we present an effective method for isolating and characterizing potential magnetite-based magnetoreceptor cells. In essence, a rotating magnetic field is employed to visually identify, within a dissociated tissue preparation, cells that contain magnetic material by their rotational behavior. As a tissue of choice, we selected trout olfactory epithelium that has been previously suggested to host candidate magnetoreceptor cells. We were able to reproducibly detect magnetic cells and to determine their magnetic dipole moment. The obtained values (4 to 100 fAm2) greatly exceed previous estimates (0.5 fAm2). The magnetism of the cells is due to a μm-sized intracellular structure of iron-rich crystals, most likely single-domain magnetite. In confocal reflectance imaging, these produce bright reflective spots close to the cell membrane. The magnetic inclusions are found to be firmly coupled to the cell membrane, enabling a direct transduction of mechanical stress produced by magnetic torque acting on the cellular dipole in situ. Our results show that the magnetically identified cells clearly meet the physical requirements for a magnetoreceptor capable of rapidly detecting small changes in the external magnetic field. This would also explain interference of ac powerline magnetic fields with magnetoreception, as reported in cattle. PMID:22778440
NASA Astrophysics Data System (ADS)
Fucugauchi, J. U.; Perez-Cruz, L. L.; Rebolledo-Vieyra, M.; Tikoo, S.; Zylberman, W.; Lofi, J.
2017-12-01
Drilling at Site M0077 sampled post-impact sediments overlying a peak ring consisting of impact breccias, melt rock and granitoids. Here we focus on characterizing the peak ring using magnetic properties, which vary widely and depend on mineralogy, depositional and emplacement conditions and secondary alterations. Rock magnetic properties are integrated with Multi-Sensor Core Logger (MSCL) data, vertical seismic profile, physical properties, petrographic and chemical analyses and geophysical models. We measure low-field magnetic susceptibility at low- and high-frequencies, intensity and direction of natural remanent magnetization (NRM) and laboratory-induced isothermal (IRM) and anhysteretic (ARM) magnetizations, alternating-field demagnetization of NRM, IRM and NRM, susceptibility variation with temperature, anisotropy of magnetic susceptibility, hysteresis and IRM back-field demagnetization. Post-impact carbonates show low susceptibilities and NRM intensities, variable frequency-dependent susceptibilities and multivectorial remanences residing in low and high coercivity minerals. Hysteresis loops show low coercivity saturation magnetizations and variable paramagnetic mineral contents. Impact breccias (suevites) and melt rock show higher susceptibilities, low frequency-dependent susceptibilities, high NRM, ARM and IRM intensities and moderate ARM intensity/susceptibility ratios. Magnetic signal is dominated by fine-grained magnetite and titanomagnetites with PSD domain states. Melt rocks at the base of impactite section show the highest susceptibilities and remanence intensities. Basement section is characterized by low susceptibilities in the granites and higher values in the dikes, with NRM and ARM intensities increasing towards the base. The high susceptibilities and remanence intensities correlate with high seismic velocities, density and decreased porosity and electrical resistivity. Fracturing and alteration account for the reduced seismic velocities, density and magnetic properties in the basement section. Site M0077 is in a horizontal gradient high within the semi-circular gravity low in the crater central zone. Correlation with MSCL logs and petrographic and chemical data will allow further detailed characterization of peak ring units.
DOT National Transportation Integrated Search
1993-04-01
The safety of magnetically levitated (maglev) and high speed rail (HSR) trains proposed for application in the United States is the responsibility of the Federal Railroad Administration (FRA). The characterization of electric and magnetic fields (EMF...
1996-01-01
used to locate and characterize a magnetic dipole source, and this finding accelerated the development of superconducting tensor gradiometers for... superconducting magnetic field gradiometer, two-color infrared camera, synthetic aperture radar, and a visible spectrum camera. The combination of these...Pieter Hoekstra, Blackhawk GeoSciences ......................................... 68 Prediction for UXO Shape and Orientation Effects on Magnetic
DOT National Transportation Integrated Search
1993-04-01
The safety of magnetically levitated (maglev) and high speed rail (HSR) trains proposed for application in the United States is the responsibility of the Federal Railroad Administration (FRA). The characterization of electric and magnetic fields (EMF...
Characterization of Plasma Discharges in a High-Field Magnetic Tandem Mirror
NASA Technical Reports Server (NTRS)
Chang-Diaz, Franklin R.
1998-01-01
High density magnetized plasma discharges in open-ended geometries, like Tandem Mirrors, have a variety of space applications. Chief among them is the production of variable Specific Impulse (I(sub sp)) and variable thrust in a magnetic nozzle. Our research group is pursuing the experimental characterization of such discharges in our high-field facility located at the Advanced Space Propulsion Laboratory (ASPL). These studies focus on identifying plasma stability criteria as functions of density, temperature and magnetic field strength. Plasma heating is accomplished by both Electron and Ion Cyclotron Resonance (ECR and ICR) at frequencies of 2-3 Ghz and 1-30 Mhz respectively, for both Hydrogen and Helium. Electron density and temperature has measured by movable Langmuir probes. Macroscopic plasma stability is being investigated in ongoing research.
Protas, Hillary D; Chen, Kewei; Langbaum, Jessica B S; Fleisher, Adam S; Alexander, Gene E; Lee, Wendy; Bandy, Daniel; de Leon, Mony J; Mosconi, Lisa; Buckley, Shannon; Truran-Sacrey, Diana; Schuff, Norbert; Weiner, Michael W; Caselli, Richard J; Reiman, Eric M
2013-03-01
To characterize and compare measurements of the posterior cingulate glucose metabolism, the hippocampal glucose metabolism, and hippocampal volume so as to distinguish cognitively normal, late-middle-aged persons with 2, 1, or 0 copies of the apolipoprotein E (APOE) ε4 allele, reflecting 3 levels of risk for late-onset Alzheimer disease. Cross-sectional comparison of measurements of cerebral glucose metabolism using 18F-fluorodeoxyglucose positron emission tomography and measurements of brain volume using magnetic resonance imaging in cognitively normal ε4 homozygotes, ε4 heterozygotes, and noncarriers. Academic medical center. A total of 31 ε4 homozygotes, 42 ε4 heterozygotes, and 76 noncarriers, 49 to 67 years old, matched for sex, age, and educational level. The measurements of posterior cingulate and hippocampal glucose metabolism were characterized using automated region-of-interest algorithms and normalized for whole-brain measurements. The hippocampal volume measurements were characterized using a semiautomated algorithm and normalized for total intracranial volume. Although there were no significant differences among the 3 groups of participants in their clinical ratings, neuropsychological test scores, hippocampal volumes (P = .60), or hippocampal glucose metabolism measurements (P = .12), there were significant group differences in their posterior cingulate glucose metabolism measurements (P = .001). The APOE ε4 gene dose was significantly associated with posterior cingulate glucose metabolism (r = 0.29, P = .0003), and this association was significantly greater than those with hippocampal volume or hippocampal glucose metabolism (P < .05, determined by use of pairwise Fisher z tests). Although our findings may depend in part on the analysis algorithms used, they suggest that a reduction in posterior cingulate glucose metabolism precedes a reduction in hippocampal volume or metabolism in cognitively normal persons at increased genetic risk for Alzheimer disease.
NASA Astrophysics Data System (ADS)
Abdulkadir, Yahya Ali; Eritro, Tigistu Haile
2017-09-01
Electrical resistivity imaging and magnetic surveys were carried out at Gergedi thermal springs, located in the Main Ethiopian Rift, to characterize the geothermal condition of the area. The area is geologically characterized by alluvial and lacustrine deposits, basaltic lava, ignimbrites, and rhyolites. The prominent structural feature in this part of the Main Ethiopian Rift, the SW -NE trending structures of the Wonji Fault Belt System, crosse over the study area. Three lines of imaging data and numerous magnetic data, encompassing the active thermal springs, were collected. Analysis of the geophysical data shows that the area is covered by low resistivity response regions at shallow depths which resulted from saline moisturized soil subsurface horizon. Relatively medium and high resistivity responses resulting from the weathered basalt, rhyolites, and ignimbrites are also mapped. Qualitative interpretation of the magnetic data shows the presence of structures that could act as pathways for heat and fluids manifesting as springs and also characterize the degree of thermal alteration of the area. Results from the investigations suggest that the Gergedi thermal springs area is controlled by fault systems oriented parallel and sub-parallel to the main tectonic lines of the Main Ethiopian Rift.
Sah, Sanjay; Myneni, Ganapati; Atulasimha, Jayasimha
2015-10-26
The magnetic properties of two important passive magnetic shielding materials (A4K and Amumetal) for accelerator applications, subjected to various processing and heat treatment conditions are studied comprehensively over a wide range of temperatures: from cryogenic to room temperature. Furthermore, we analyze the effect of processing on the extent of degradation of the magnetic properties of both materials and investigate the possibility of restoring these properties by re-annealing.
Metabolomic signature associated with reproduction-regulated aging in Caenorhabditis elegans.
Wan, Qin-Li; Shi, Xiaohuo; Liu, Jiangxin; Ding, Ai-Jun; Pu, Yuan-Zhu; Li, Zhigang; Wu, Gui-Sheng; Luo, Huai-Rong
2017-02-06
In Caenorhabditis elegans (C. elegans) , ablation of germline stem cells (GSCs) leads to infertility, which extends lifespan. It has been reported that aging and reproduction are both inextricably associated with metabolism. However, few studies have investigated the roles of polar small molecules metabolism in regulating longevity by reproduction. In this work, we combined the nuclear magnetic resonance (NMR) and ultra-performance liquid chromatography-mass spectrometry (UPLC-MS) to profile the water-soluble metabolome in C. elegans . Comparing the metabolic fingerprint between two physiological ages among different mutants, our results demonstrate that aging is characterized by metabolome remodeling and metabolic decline. In addition, by analyzing the metabolic profiles of long-lived germline-less glp-1 mutants, we discovered that glp-1 mutants regulate the levels of many age-variant metabolites to attenuate aging, including elevated concentrations of the pyrimidine and purine metabolism intermediates and decreased concentrations of the citric acid cycle intermediates. Interestingly, by analyzing the metabolome of daf-16;glp-1 double mutants, our results revealed that some metabolic exchange contributing to germline-mediated longevity was mediated by transcription factor FOXO/DAF-16, including pyrimidine metabolism and the TCA cycle. Based on a comprehensive metabolic analysis, we provide novel insight into the relationship between longevity and metabolism regulated by germline signals in C. elegans .
Metabolomic signature associated with reproduction-regulated aging in Caenorhabditis elegans
Wan, Qin-Li; Shi, Xiaohuo; Liu, Jiangxin; Ding, Ai-Jun; Pu, Yuan-Zhu; Li, Zhigang; Wu, Gui-Sheng; Luo, Huai-Rong
2017-01-01
In Caenorhabditis elegans (C. elegans), ablation of germline stem cells (GSCs) leads to infertility, which extends lifespan. It has been reported that aging and reproduction are both inextricably associated with metabolism. However, few studies have investigated the roles of polar small molecules metabolism in regulating longevity by reproduction. In this work, we combined the nuclear magnetic resonance (NMR) and ultra-performance liquid chromatography-mass spectrometry (UPLC-MS) to profile the water-soluble metabolome in C. elegans. Comparing the metabolic fingerprint between two physiological ages among different mutants, our results demonstrate that aging is characterized by metabolome remodeling and metabolic decline. In addition, by analyzing the metabolic profiles of long-lived germline-less glp-1 mutants, we discovered that glp-1 mutants regulate the levels of many age-variant metabolites to attenuate aging, including elevated concentrations of the pyrimidine and purine metabolism intermediates and decreased concentrations of the citric acid cycle intermediates. Interestingly, by analyzing the metabolome of daf-16;glp-1 double mutants, our results revealed that some metabolic exchange contributing to germline-mediated longevity was mediated by transcription factor FOXO/DAF-16, including pyrimidine metabolism and the TCA cycle. Based on a comprehensive metabolic analysis, we provide novel insight into the relationship between longevity and metabolism regulated by germline signals in C. elegans PMID:28177875
NASA Astrophysics Data System (ADS)
Veglio, E.; Ugalde, H. A.; Lenauer, I.; Milkereit, B.
2017-12-01
Magnetic anomalies near areas of known base metal sulphide mineralization were seen in regional airborne data from the Bay of Chaleur in northern New Brunswick, Canada. A ground magnetic investigation was performed over this area to better characterize the source of these regional anomalies and to investigate their relation to the sulphide mineralization. The mineralization is hosted in Late Silurian to Early Devonian volcano-sedimentary stratigraphy and has been identified in several boreholes. This volcano-sedimentary stratigraphy was deposited in a half-graben shallow marine setting, where hydrothermal fluids transported sulphide mineralization through a fault network. The ground magnetic surveys show that two anomalous regions characterized by a total magnetic field of 54,100 nT and 55,500 nT, whereas the shallow alteration associated with mineralized zones are approximately 53,450 nT. These are significant magnetic anomalies are close to 700 nT and 2,000 nT greater than the surrounding area. In order to compare the ground data to the existing airborne, the ground magnetic data was upward continued to a height of 100 meters. The few occurrences of bedrock outcrops on the property confirm the occurrence of rhyolites and tuffs, as well as the presence of sulphide mineralization. However, much of the study area is densely vegetated and covered by glacial sediments of up to 25 meters thickness. Thus, to better interpret the geology and occurrence of the sulphide mineralization, several boreholes were examined on the basis of magnetic susceptibility and further correlated with the borehole logs and observations of lithologies in core. It was found that an individual mafic unit has several orders of magnitude higher magnetic susceptibility than the alteration zones and felsic tuffs where mineralization occurs. This indicates that the magnetic anomaly identified both in the regional magnetic survey and the ground survey is likely caused by the occurrence of this mafic unit. Petrographic analysis of this unit indicates it is a diabase dyke. Further characterization of the host rocks of the sulphide mineralization and the alteration will be accomplished by incorporating historic petrophysical studies of density and conductivity to complement the existing magnetic susceptibility measurements.
Geometric magnetic frustration in RE{sub 2}O{sub 2}S oxysulfides (RE = Sm, Eu and Gd)
DOE Office of Scientific and Technical Information (OSTI.GOV)
Biondo, V.; Sarvezuk, P.W.C.; Ivashita, F.F.
2014-06-01
Graphical abstract: Stacked planes in the <001> direction of an oxysulfide structure, showing the triangular nets formed by rare earth cations, which moments present geometric magnetic frustration. - Highlights: • We prepared monophasic RE{sub 2}O{sub 2}S Oxysulfides (RE = Sm, Eu and Gd). • RE{sub 2}O{sub 2}S compounds were characterized regarding structural and magnetic properties. • Mössbauer spectra were obtained for Eu{sub 2}O{sub 2}S and Gd{sub 2}O{sub 2}S at different temperatures. • Oxysulfides present geometric magnetic frustration of the rare-earth sublattice. - Abstract: RE{sub 2}O{sub 2}S oxysulfides (with RE = Sm, Eu and Gd) were prepared and characterized regarding theirmore » structural and magnetic properties. The compounds crystallized in the trigonal symmetry (space group P-3m/D{sub 3}{sup 3}d), with the lattice parameter varying linearly with the ionic radius of the RE cation. All these oxysulfides are magnetically frustrated and only the gadolinium sample showed magnetic order down to 3 K. The magnetic frustration is attributed to the spatial distribution of cations over the lattice, where the RE’s magnetic moments occupy the sites forming a triangular plane lattice, perpendicular to the direction. This geometric magnetic frustration was firstly recognized for these oxysulfides.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Martins, Marcel G.; Martins, Daniel O.T.A.; Carvalho, Beatriz L.C. de
2015-08-15
In this work montmorillonite (MMT) clay, whose matrix was modified with an ammonium salt (hexadecyltrimethylammonium bromide – CTAB), was employed as an inorganic host for the intercalation of three different molecular magnetic compounds through ion exchange: a nitronyl nitroxide derivative 2-[4-(N-ethyl)-pyridinium]-4,4,5,5-tetramethylimidazoline-1-oxyl-3-oxide (p-EtRad{sup +}) and two binuclear coordination compounds, [Ni(valpn)Ln]{sup 3+}, where H{sub 2}valpn stands for 1,3-propanediyl-bis(2-iminomethylene-6-methoxy-phenol), and Ln=Gd{sup III}; Dy{sup III}. The pristine MMT and the intercalated materials were characterized by X-ray powder diffraction (XRD), infrared spectroscopy (IR), scanning electron microscopy (SEM), thermogravimetric analysis (TGA) and magnetic measurements. The X-ray diffraction data analysis showed an increase of the interlamellar spacemore » of the intercalated MMT, indicating the intercalation of the magnetic compounds. Furthermore, the magnetic properties of the hybrid compounds were investigated, showing similar behavior as the pure magnetic guest species. - Graphical abstract: Montmorillonite clay was employed as inorganic host for the intercalation of three different molecular magnetic compounds through ion exchange - Highlights: • Montmorillonite was employed as a host material. • Three molecular magnetic compounds were intercalated through ion exchange. • The compounds were successful intercalated maintaining the layered structure. • The hybrid materials exhibited similar magnetic behavior as the pure magnetic guest.« less
Magnetic Multi-Scale Mapping to Characterize Anthropogenic Targets
NASA Astrophysics Data System (ADS)
Le Maire, P.; Munschy, M.
2017-12-01
The discovery of buried anthropic objects on construction sites can cause delays and/or dangers for workers and for the public. Indeed, every year 500 tons of Unexploded-ordnance are discovered in France. Magnetic measurements are useful to localize magnetized objects. Moreover, it is the cheapest geophysical method which does not impact environment and which is relatively fast to perform. Fluxgate magnetometers (three components) are used to measure magnetic properties bellow the ground. These magnetic sensors are not absolute, so they need to be calibrated before the onset of the measurements. The advantage is that they allow magnetic compensation of the equipment attached to the sensor. So the choice of this kind sensor gives the opportunity to install the equipment aboard different magnetized supports: boat, quad bike, unmanned aerial vehicle, aircraft,... Indeed, this methodology permits to perform magnetic mapping with different scale and different elevation above ground level. An old French aerial military plant was chosen to perform this multi-scale approach. The advantage of the site is that it contains a lot of different targets with variable sizes and depth, e.g. buildings, unexploded-ordnances of the two world wars, trenches, pipes,… By comparison between the different magnetic anomaly maps at different elevations some of the geometric parameters of the magnetic sources can be characterized. The comparison between measured maps at different elevations and the prolonged map highlights the maximum distance for the target's detection (figure).
Olivieri, Laura J.; Baba, Ridhwan Y.; Arai, Andrew E.; Bandettini, W. Patricia; Rosing, Douglas R.; Bakalov, Vladimir; Sachdev, Vandana; Bondy, Carolyn A.
2014-01-01
Background Congenital aortic valve fusion is associated with aortic dilation, aneurysm and rupture in girls and women with Turner syndrome (TS). Our objective was to characterize aortic valve structure in subjects with TS, and determine the prevalence of aortic dilation and valve dysfunction associated with different types of aortic valves. Methods and Results The aortic valve and thoracic aorta were characterized by cardiovascular magnetic resonance imaging in 208 subjects with TS in an IRB-approved natural history study. Echocardiography was used to measure peak velocities across the aortic valve, and the degree of aortic regurgitation. Four distinct valve morphologies were identified: tricuspid aortic valve (TAV) 64%(n=133), partially fused aortic valve (PF) 12%(n=25), bicuspid aortic valve (BAV) 23%(n=47), and unicuspid aortic valve (UAV) 1%(n=3). Age and body surface area (BSA) were similar in the 4 valve morphology groups. There was a significant trend, independent of age, towards larger BSA-indexed ascending aortic diameters (AADi) with increasing valve fusion. AADi were (mean +/− SD) 16.9 +/− 3.3 mm/m2, 18.3 +/− 3.3 mm/m2, and 19.8 +/− 3.9 mm/m2 (p<0.0001) for TAV, PF and BAV+UAV respectively. PF, BAV, and UAV were significantly associated with mild aortic regurgitation and elevated peak velocities across the aortic valve. Conclusions Aortic valve abnormalities in TS occur with a spectrum of severity, and are associated with aortic root dilation across age groups. Partial fusion of the aortic valve, traditionally regarded as an acquired valve problem, had an equal age distribution and was associated with an increased AADi. PMID:24084490
Magnetization of the oceanic crust: TRM or CRM?
NASA Technical Reports Server (NTRS)
Raymond, C. A.; Labrecque, J. L.
1987-01-01
A model was proposed in which chemical remanent magnetization (CRM) acquired within the first 20 Ma of crustal evolution may account for 80% of the bulk natural remanent magnetization (NRM) of older basalts. The CRM of the crust is acquired as the original thermoremanent magnetization (TRM) is lost through low temperature alteration. The CRM intensity and direction are controlled by the post-emplacement polarity history. This model explains several independent observations concerning the magnetization of the oceanic crust. The model accounts for amplitude and skewness discrepancies observed in both the intermediate wavelength satellite field and the short wavelength sea surface magnetic anomaly pattern. It also explains the decay of magnetization away from the spreading axis, and the enhanced magnetization of the Cretaceous Quiet Zones while predicting other systematic variations with age in the bulk magnetization of the oceanic crust. The model also explains discrepancies in the anomaly skewness parameter observed for anomalies of Cretaceous age. Further studies indicate varying rates of TRM decay in very young crust which depicts the advance of low temperature alteration through the magnetized layer.
Rare-earth magnet ingestion: a childhood danger reaches adolescence.
Agha, Beesan Shalabi; Sturm, Jesse J; Costello, Brian E
2013-10-01
Ingestion of multiple magnets may cause serious gastrointestinal morbidity, such as pressure necrosis, perforation, fistula formation, or intestinal obstruction due to forceful attraction across bowel wall. Although the consequences of multiple magnet ingestion are well documented in young children, the current popularity of small, powerful rare-earth magnets marketed as "desk toys" has heightened this safety concern in all pediatric age groups. A recent US Consumer Product Safety Commission product-wide warning additionally reports the adolescent practice of using toy high-powered, ball-bearing magnets to simulate tongue and lip piercings, a behavior that may increase risk of inadvertent ingestion. We describe 2 cases of older children (male; aged 10 and 13 years, respectively) with unintentional ingestion of multiple rare-earth magnets. Health care providers should be alerted to the potential for misuse of these high-powered, ball-bearing magnets among older children and adolescents.
Xie, Yuhuan; Chen, Yian Ann; De Bellis, Michael D.
2011-01-01
In healthy children, there is a paucity of information on the growth of the brainstem and thalamus measured by anatomical magnetic resonance imaging. The relationships of age, gender, and age by gender with brainstem and thalamus volumes were analyzed from magnetic resonance brain images of 122 healthy children and adolescents (62 males, 60 females; ages four to seventeen). Results showed that age is a significant predictor of brainstem and thalamus volumes. The volume of the brainstem increases with age, while thalamus volume declines with age. The volumes of right thalami are significantly larger than that of left in both genders with greater rightward asymmetry and greater thalamus/grey matter ratio in females. Males have larger brainstems, but these differences are not significant when covarying for cerebral volumes. Larger thalami were associated with higher verbal IQ. This normative pediatric data is of value to researchers who study these regions in neurodevelopmental disorders. PMID:21954432
Xie, Yuhuan; Chen, Yian Ann; De Bellis, Michael D
2012-03-01
In healthy children, there is a paucity of information on the growth of the brainstem and thalamus measured anatomically magnetic resonance imaging. The relations of age, gender, and age by gender with brainstem and thalamus volumes were analyzed from magnetic resonance brain images of 122 healthy children and adolescents (62 males, 60 females; ages 4 to 17). Results showed that age is a significant predictor of brainstem and thalamus volumes. The volume of the brainstem increases with age, while thalamus volume declines with age. The volume of the right thalamus is significantly larger than that of the left in both genders, with greater rightward asymmetry and greater thalamus to grey matter ratio in females. Males have larger brainstems, but these differences are not significant when covarying for cerebral volume. Larger thalami were associated with higher Verbal IQ. These normative pediatric data are of value to researchers who study these regions in neurodevelopmental disorders.
NASA Astrophysics Data System (ADS)
Gherca, Daniel; Pui, Aurel; Cornei, Nicoleta; Cojocariu, Alina; Nica, Valentin; Caltun, Ovidiu
2012-11-01
We focused on obtaining MFe2O4 nanoparticles using ricin oil solution as surfactant and on their structural characterization and magnetic properties. The annealed samples at 500 °C in air for 6 h were analyzed for the crystal phase identification by powder X-ray diffraction using CuKα radiation. The particle size, the chemical composition and the morphology of the calcinated powders were characterized by scanning electron microscopy. All sintered samples contain only one phase, which has a cubic structure with crystallite sizes of 12-21 nm. From the infrared spectra of all samples were observed two strong bands around 600 and 400 cm-1, which correspond to the intrinsic lattice vibrations of octahedral and tetrahedral sites of the spinel structure, respectively, and characteristic vibration for capping agent. The magnetic properties of fine powders were investigated at room temperature by using a vibrating sample magnetometer. The room temperature M-H hysteresis loops show ferromagnetic behavior of the calcined samples, with specific saturation magnetization (Ms) values ranging between 11 and 53 emu/g.
Jordanova, N; Petrovský, E; Kapicka, A; Jordanova, D; Petrov, P
2017-04-01
Copper ore mining and processing are among the most harmful anthropogenic influences for the environment and they are a subject of international and national law regulations. Recultivation of areas influenced by mining and processing industry is commonly applied and monitored in order to restore as much as possible the natural environment. In this study, environmental magnetic methods are applied in order to assess the degree of soil restoration in terms of soil development, after remediation of waste dump from Cu-processing plant. Soils developed under birch forest stands of different age (5, 15, and 25 years) as well as raw waste material were sampled along depth down to 20-30 cm. Variations in magnetic parameters and ratios obtained (magnetic susceptibility, frequency-dependent magnetic susceptibility, anhysteretic remanence (ARM), isothermal remanence (IRM), ARM/IRM 100mT ) suggest the presence of magnetic enhancement in the upper 0-15 cm, the thickness of this layer varying depending on the age of the forest stand. Magnetic mineral responsible for this enhancement is of magnetite type, while waste material contains a large amount of hematite, as evidenced by coercivity analysis of IRM acquisition curves and thermal demagnetization of composite IRM. Magnetic grain-sized proxy parameters suggest that magnetite particles are coarser, magnetically stable, while no or minor amount of superparamagnetic grains were detected at room temperature. A well-defined linear regression between the topsoil magnetic susceptibility and the approximate age of the forest stand provides an indication that the magnetic enhancement is of pedogenic origin. It is concluded that the observed magnetic enhancement of recultivated soils studied is linked to a combined effect of pedogenic contribution and possible additions of industrial ashes as a liming agent for soil restoration.
Characterizing Weak-Link Effects in Mo/Au Transition-Edge Sensors
NASA Technical Reports Server (NTRS)
Smith, Stephen
2011-01-01
We are developing Mo/Au bilayer transition-edge sensors (TESs) for applications in X-ray astronomy. Critical current measurements on these TESs show they act as weak superconducting links exhibiting oscillatory, Fraunhofer-like, behavior with applied magnetic field. In this contribution we investigate the implications of this behavior for TES detectors, under operational bias conditions. This includes characterizing the logarithmic resistance sensitivity with temperature, (alpha, and current, beta, as a function of applied magnetic field and bias point within the resistive transition. Results show that these important device parameters exhibit similar oscillatory behavior with applied magnetic field, which in turn affects the signal responsivity, noise and energy resolution.
Magnetic Nanoparticle Drug Carriers and their Study by Quadrupole Magnetic Field-Flow Fractionation
Williams, P. Stephen; Carpino, Francesca; Zborowski, Maciej
2009-01-01
Magnetic nanoparticle drug carriers continue to attract considerable interest for drug targeting in the treatment of cancers and other pathological conditions. The efficient delivery of therapeutic levels of drug to a target site while limiting nonspecific, systemic toxicity requires optimization of the drug delivery materials, the applied magnetic field, and the treatment protocol. The history and current state of magnetic drug targeting is reviewed. While initial studies involved micron-sized and larger carriers, and work with these microcarriers continues, it is the sub-micron carriers or nanocarriers that are of increasing interest. An aspect of magnetic drug targeting using nanoparticle carriers that has not been considered is then addressed. This aspect involves the variation in the magnetic properties of the nanocarriers. Quadrupole magnetic field-flow fractionation (QMgFFF) is a relatively new technique for characterizing magnetic nanoparticles. It is unique in its capability of determining the distribution in magnetic properties of a nanoparticle sample in suspension. The development and current state of this technique is also reviewed. Magnetic nanoparticle drug carriers have been found by QMgFFF analysis to be highly polydisperse in their magnetic properties, and the strength of response of the particles to magnetic field gradients is predicted to vary by orders of magnitude. It is expected that the least magnetic fraction of a formulation will contribute the most to systemic toxicity, and the depletion of this fraction will result in a more effective drug carrying material. A material that has a reduced systemic toxicity will allow higher doses of cytotoxic drugs to be delivered to the tumor with reduced side effects. Preliminary experiments involving a novel method of refining a magnetic nanoparticle drug carrier to achieve this result are described. QMgFFF is used to characterize the refined and unrefined material. PMID:19591456
Magnetic Measurements of the First Nb 3Sn Model Quadrupole (MQXFS) for the High-Luminosity LHC
DiMarco, J.; Ambrosio, G.; Chlachidze, G.; ...
2016-12-12
The US LHC Accelerator Research Program (LARP) and CERN are developing high-gradient Nb 3Sn magnets for the High Luminosity LHC interaction regions. Magnetic measurements of the first 1.5 m long, 150 mm aperture model quadrupole, MQXFS1, were performed during magnet assembly at LBNL, as well as during cryogenic testing at Fermilab’s Vertical Magnet Test Facility. This paper reports on the results of these magnetic characterization measurements, as well as on the performance of new probes developed for the tests.
Magnetic measurements of the XLS magnets
DOE Office of Scientific and Technical Information (OSTI.GOV)
Solomon, L.; Galayda, J.; Sylvester, C.
1991-01-01
The magnets designed and built for Phase 1 (200MeV) of the XLS (X-Ray Lithography Source) project have all been measured and characterized. In this paper, the measurement system designed and utilized for the Phase 1 180 degree dipole magnets is reviewed. Hall probe measurements of the two dipole magnets, with a field of 1.1 Tesla at 1200 amperes, are discussed and presented. Phase 2 (700MeV) of this project includes replacement of the two room temperature dipole magnets with superconducting dipoles (3.9Tesla). 3 figs., 1 tab.
Periodate oxidation of nanoscaled magnetic dextran composites
NASA Astrophysics Data System (ADS)
Hong, Xia; Guo, Wei; Yuan, Hang; Li, Jun; Liu, Yanmei; Ma, Lan; Bai, Yubai; Li, Tiejin
2004-02-01
Highly hydrophilic, uniform and nontoxic magnetic fluids consisting of magnetite (Fe 3O 4) and dextran were prepared. A periodate oxidation method was used to further activate the magnetic dextran, forming magnetic polyaldehyde-dextran, which could be conjugated to biomolecules such as proteins or antibodies. Oxidated Magnetic dextran composites were characterized by TEM, XRD and SQUID magnetometry. Moreover, a flexible, rapid and simple method to detect aldehydes was introduced to the magnetic composite system by utilizing 2,4-dinitrophenylhydrazine reagent. The result of the quantitative analysis of aldehyde was given by thermogravimetric analysis and elemental analysis.
The Effect of Ligands on FePt–Fe 3O 4 Core–Shell Magnetic Nanoparticles
Kim, Dong-Hyun; Tamada, Yoshinori; Ono, Teruo; ...
2014-03-01
FePt–Fe 3O 4 core–shell nanoparticles functionalized with 3,4-dihydroxyphenylacetic acid (DOPAC) and dimercaptosuccinic acid (DMSA) ligands were synthesized and characterized. We also found that the DOPAC ligand enhances the magnetic properties of the FePt–Fe 3O 4 particles, in comparison with the DMSA ligand, which induces the oxidation of the shell layer that causes a significant reduction of the saturation magnetization. We evaluated the synthesized magnetic nanoparticles for applications in magnetic hyperthermia and magnetic resonance imaging contrast enhancement.
Chaturvedi, Abhishek; Gange, Chris; Sahin, Hakan; Chaturvedi, Apeksha
2018-01-01
Mediastinal and paracardiac lesions are usually first diagnosed on a chest radiograph or echocardiogram. Often, a computed tomography is obtained to further delineate these lesions. CT may be suboptimal for evaluation of enhancement characteristics and direct extension into the adjacent mediastinal structures. With its intrinsic superior soft-tissue characterization, magnetic resonance imaging (MRI) can better delineate these lesions, their internal tissue characteristics, and identify adhesion/invasion into adjacent structures. This pictorial essay provides a brief synopsis of the key MRI sequences and their utility in further characterizing mediastinal and paracardiac lesions. PMID:29619281
THE INTERNAL STRUCTURE OF OVERPRESSURED, MAGNETIZED, RELATIVISTIC JETS
DOE Office of Scientific and Technical Information (OSTI.GOV)
Martí, J. M.; Perucho, M.; Gómez, J. L.
This work presents the first characterization of the internal structure of overpressured, steady superfast-magnetosonic relativistic jets in connection with their dominant type of energy. To this aim, relativistic magnetohydrodynamic simulations of different jet models threaded by a helical magnetic field have been analyzed covering a wide region in the magnetosonic Mach number–specific internal energy plane. The merit of this plane is that models dominated by different types of energy (internal energy: hot jets; rest-mass energy: kinetically dominated jets; magnetic energy: Poynting-flux-dominated jets) occupy well-separated regions. The analyzed models also cover a wide range of magnetizations. Models dominated by the internalmore » energy (i.e., hot models, or Poynting-flux-dominated jets with magnetizations larger than but close to one) have a rich internal structure characterized by a series of recollimation shocks and present the largest variations in the flow Lorentz factor (and internal energy density). Conversely, in kinetically dominated models, there is not much internal or magnetic energy to be converted into kinetic, and the jets are featureless with small variations in the flow Lorentz factor. The presence of a significant toroidal magnetic field threading the jet produces large gradients in the transversal profile of the internal energy density. Poynting-flux-dominated models with high magnetization (≈10 or larger) are prone to be unstable against magnetic pinch modes, which sets limits on the expected magnetization in parsec-scale active galactic nucleus jets or constrains their magnetic field configuration.« less
Enhanced pulsed magneto-motive ultrasound imaging using superparamagnetic nanoclusters
Mehrmohammadi, M; Yoon, KY; Qu, M; Johnston, KP; Emelianov, SY
2011-01-01
Recently, pulsed magneto-motive ultrasound (pMMUS) imaging augmented with ultra-small magnetic nanoparticles has been introduced as a tool capable of imaging events at molecular and cellular levels. The sensitivity of a pMMUS system depends on several parameters, including the size, geometry and magnetic properties of the nanoparticles. Under the same magnetic field, larger magnetic nanostructures experience a stronger magnetic force and produce larger displacement, thus improving the sensitivity and signal-to-noise ratio (SNR) of pMMUS imaging. Unfortunately, large magnetic iron-oxide nanoparticles are typically ferromagnetic and thus are very difficult to stabilize against colloidal aggregation. In the current study we demonstrate improvement of pMMUS image quality by using large size superparamagnetic nanoclusters characterized by strong magnetization per particle. Water-soluble magnetic nanoclusters of two sizes (15 and 55 nm average size) were synthesized from 3 nm iron precursors in the presence of citrate capping ligand. The size distribution of synthesized nanoclusters and individual nanoparticles was characterized using dynamic light scattering (DLS) analysis and transmission electron microscopy (TEM). Tissue mimicking phantoms containing single nanoparticles and two sizes of nanoclusters were imaged using a custom-built pMMUS imaging system. While the magnetic properties of citrate-coated nanoclusters are identical to those of superparamagnetic nanoparticles, the magneto-motive signal detected from nanoclusters is larger, i.e. the same magnetic field produced larger magnetically induced displacement. Therefore, our study demonstrates that clusters of superparamagnetic nanoparticles result in pMMUS images with higher contrast and SNR. PMID:21157009
Pleistocene climate change inferred from multi-proxy analyses of a loess-paleosol sequence in China
NASA Astrophysics Data System (ADS)
Wu, Yi; Qiu, Shifan; Fu, Shuqing; Rao, Zhiguo; Zhu, Zhaoyu
2018-04-01
The aeolian loess blanketing the Chinese Loess Plateau (CLP) is sensitive to climate change in monsoonal East Asia. Here, we present a multi-proxy climatic record from a Pleistocene loess-paleosol sequence from the Lantian Basin on the southern margin of the CLP. The measurements include magnetic susceptibility and related magnetic properties, bulk median grain-size, color reflectance, and the color-inferred hematite versus goethite ratio (Hm/Gt). A long-term aridification and cooling trend during the interval from ca 2.22-0.43 Ma is indicated by two magnetic grain-size proxies, corresponding to the global climatic cooling of the late Cenozoic. In addition, at least four intervals of climatic extremes are evident in the record of Hm/Gt ratio: at 1.71-1.65 Ma, 1.26-1.24 Ma, 0.94-0.86 Ma, and 0.62-0.48 Ma. These intervals are characterized by distinct regional climates, which contrast with the global climatic conditions represented in marine sediments. For example, a relatively arid climate is documented from 1.71 to 1.65 Ma, which was rapidly succeeded by a relatively humid climate which is associated with the earliest hominin (with an age of ca 1.63 Ma) in the Lantian Basin.
Late-Eburnean tectonic emplacement of Wayen syenite (Burkina Faso)
NASA Astrophysics Data System (ADS)
Seydoux Traoré, Abraham; Naba, Séta; Lompo, Martin
2010-05-01
The alkali plutonism of the Palaeoproterozoic domain of the West African craton remains very poorly studied. The rare data available are those from the Ninakri syenite and the alkali granites of central Côte d'Ivoire (Bonhomme, 1962; Morel and Alinat, 1993 ; Doumbia et al, 1998) and those of the alkali granites of central Burkina Faso (Wenmenga, 1986). All these studies focused on the petrographical characterization and the determination of the radiometric ages of these plutons. All ages were determined by the Rb/Sr and they vary between 1.8 Ga and 2.1 Ga. The span of emplacement ages suggests that the alkali plutonism of the Palaeoproterozoic of West Africa continued throughout the tectono-magmatic history of the craton. The purpose of the present study is to characterize the late eburnean tectonic processes using the structural data of the Wayen syenite which was dated at 2.1 Ga by Rb/Sr isochron by Vachette and Ouédraogo (1978) Map view and field relationships show that the Wayen syenite intrudes the metavolcanic and early plutonic rocks (tonalites, trondhjemites and granodiorites). The geochemical data show that the syenite has a peraluminous character (Peccerrilo and Taylor, 1976) and belongs to the S-type granitoids (Chappell and White, 1992). The structural data have been obtained by magnetic susceptibility (Km) measurements on 190 samples from 47 sampling stations. The values of susceptibility range between 253 µSI and 595,314 µSI. This means that we have both samples with ferromagnetic character (Km > 500 µSI) and paramagnetic character (Km ≤ 500 µSI). In the case of paramagnetism, the minerals bearing the magnetic susceptibility are ferriferous silicates (amphiboles and pyroxenes) whereas the in the ferromagnetic samples, it is magnetite. The microstructures of the syenite are mostly magmatic and very locally they show both high temperature solid state deformation features and relatively low temperature solid state conditions along narrow shear bands. At the map scale the regular orientation of lineations and foliations strongly suggests that the eburnean tectonic event was active during emplacement, which contradicts the widespread idea that the syenites represent post-orogenic granitoids.
Particle Transport in Therapeutic Magnetic Fields
NASA Astrophysics Data System (ADS)
Puri, Ishwar K.; Ganguly, Ranjan
2014-01-01
Iron oxide magnetic nanoparticles, in ferrofluids or as magnetic microspheres, offer magnetic maneuverability, biochemical surface functionalization, and magnetic relaxation under the influence of an alternating field. The use of these properties for clinical applications requires an understanding of particles, forces, and scalar transport at various length scales. This review explains the behavior of magnetic nano- and microparticles during magnetic drug targeting and magnetic fluid hyperthermia, and the microfluidic transport of these particles in bioMEMS (biomedical microelectromechanical systems) devices for ex vivo therapeutic and diagnostic applications. Magnetic particle transport, the momentum interaction of these particles with a host fluid in a flow, and thermal transport in a particle-infused tissue are characterized through the governing electrodynamic, hydrodynamic, and scalar transport equations.
Kim, Jieun; Choi, In-Young; Duff, Karen E; Lee, Phil
2017-06-01
Tauopathies such as Alzheimer's disease and frontotemporal lobe degeneration (FTLD-tau) dementia, characterized by pathologic aggregation of the microtubule-associated tau protein and formation of neurofibrillary tangles, have been linked to neurodegeneration and cognitive decline. The early detection of cerebral abnormalities and the identification of biological contributors to the continuous pathologic processes of neurodegeneration in tauopathies critically hinge on sensitive and reliable measures of biomarkers in the living brain. In this study, we measured alterations in a number of key neurochemicals associated with tauopathy-induced neurodegeneration in the hippocampus and the olfactory bulbs of a transgenic mouse model of FTLD-tauopathy, line rTg4510, using in vivo 1 H magnetic resonance spectroscopy at 9.4 T. The rTg4510 line develops tauopathy at a young age (4-5 months), reaching a severe stage by 8-12 months of age. Longitudinal measurement of neurochemical concentrations in the hippocampus of mice from 5 to 12 months of age showed significant progressive changes with distinctive disease staging patterns including N-acetylaspartate, myo-inositol, γ-aminobutyric acid, glutathione and glutamine. The accompanying hippocampal volume loss measured using magnetic resonance imaging showed significant correlation (p < 0.01) with neurochemical measurements. Neurochemical alterations in the olfactory bulbs were more pronounced than those in the hippocampus in rTg4510 mice. These results demonstrate progressive neuropathology in the mouse model and provide potential biomarkers of early neuropathological events and effective noninvasive monitoring of the disease progression and treatment efficacy, which can be easily translated to clinical studies.
Synergy and destructive interferences between local magnetic anisotropies in binuclear complexes
DOE Office of Scientific and Technical Information (OSTI.GOV)
Guihéry, Nathalie; Ruamps, Renaud; Maurice, Rémi
2015-12-31
Magnetic anisotropy is responsible for the single molecule magnet behavior of transition metal complexes. This behavior is characterized by a slow relaxation of the magnetization for low enough temperatures, and thus for a possible blocking of the magnetization. This bistable behavior can lead to possible technological applications in the domain of data storage or quantum computing. Therefore, the understanding of the microscopic origin of magnetic anisotropy has received a considerable interest during the last two decades. The presentation focuses on the determination of the anisotropy parameters of both mono-nuclear and bi-nuclear types of complexes and on the control and optimizationmore » of the anisotropic properties. The validity of the model Hamiltonians commonly used to characterize such complexes has been questioned and it is shown that neither the standard multispin Hamiltonian nor the giant spin Hamiltonian are appropriate for weakly coupled ions. Alternative models have been proposed and used to properly extract the relevant parameters. Rationalizations of the magnitude and nature of both local anisotropies of single ions and the molecular anisotropy of polynuclear complexes are provided. The synergy and interference effects between local magnetic anisotropies are studied in a series of binuclear complexes.« less
NASA Technical Reports Server (NTRS)
Freeman, M. P.; Farrugia, C. J.; Burlaga, L. F.; Hairston, M. R.; Greenspan, M. E.; Ruohoniemi, J. M.; Lepping, R. P.
1993-01-01
Observations are presented of the ionospheric convection in cross sections of the polar cap and auroral zone as part of the study of the interaction of the Earth's magnetosphere with the magnetic cloud of January 13-15, 1988. For strongly northward IMF, the convection in the Southern Hemisphere is characterized by a two-cell convection pattern comfined to high latitudes with sunward flow over the pole. The strength of the flows is comparable to that later seen under southward IMF. Superimposed on this convection pattern there are clear dawn-dusk asymmetries associated with a one-cell convection component whose sense depends on the polarity of the magnetic cloud's large east-west magnetic field component. When the cloud's magnetic field turns southward, the convection is characterized by a two-cell pattern extending to lower latitude with antisunward flow over the pole. There is no evident interhemispheric difference in the structure and strength of the convection. Superimposed dawn-dusk asymmetries in the flow patterns are observed which are only in part attributable to the east-west component of the magnetic field.
Recent Advances in Cardiovascular Magnetic Resonance Techniques and Applications
Salerno, Michael; Sharif, Behzad; Arheden, Håkan; Kumar, Andreas; Axel, Leon; Li, Debiao; Neubauer, Stefan
2018-01-01
Cardiovascular magnetic resonance imaging has become the gold standard for evaluating myocardial function, volumes, and scarring. Additionally, cardiovascular magnetic resonance imaging is unique in its comprehensive tissue characterization, including assessment of myocardial edema, myocardial siderosis, myocardial perfusion, and diffuse myocardial fibrosis. Cardiovascular magnetic resonance imaging has become an indispensable tool in the evaluation of congenital heart disease, heart failure, cardiac masses, pericardial disease, and coronary artery disease. This review will highlight some recent novel cardiovascular magnetic resonance imaging techniques, concepts, and applications. PMID:28611116
Single molecule magnet behaviour in robust dysprosium-biradical complexes.
Bernot, Kevin; Pointillart, Fabrice; Rosa, Patrick; Etienne, Mael; Sessoli, Roberta; Gatteschi, Dante
2010-09-21
A Dy-biradical complex was synthesized and characterized down to very low temperature. ac magnetic measurements reveal single molecule magnet behaviour visible without any application of dc field. The transition to the quantum tunneling regime is evidenced. Photophysical and EPR measurements provide evidence of the excellent stability of these complexes in solution.
Out-of-plane easy-axis in thin films of diluted magnetic semiconductor Ba1-xKx(Zn1-yMny)2As2
NASA Astrophysics Data System (ADS)
Wang, R.; Huang, Z. X.; Zhao, G. Q.; Yu, S.; Deng, Z.; Jin, C. Q.; Jia, Q. J.; Chen, Y.; Yang, T. Y.; Jiang, X. M.; Cao, L. X.
2017-04-01
Single-phased, single-oriented thin films of Mn-doped ZnAs-based diluted magnetic semiconductor (DMS) Ba1-xKx(Zn1-yMny)2As2 (x = 0.03, 0.08; y = 0.15) have been deposited on Si, SrTiO3, LaAlO3, (La,Sr)(Al,Ta)O3, and MgAl2O4 substrates, respectively. Utilizing a combined synthesis and characterization system excluding the air and further optimizing the deposition parameters, high-quality thin films could be obtained and be measured showing that they can keep inactive-in-air up to more than 90 hours characterized by electrical transport measurements. In comparison with films of x = 0.03 which possess relatively higher resistivity, weaker magnetic performances, and larger energy gap, thin films of x = 0.08 show better electrical and magnetic performances. Strong magnetic anisotropy was found in films of x = 0.08 grown on (La,Sr)(Al,Ta)O3 substrate with their magnetic polarization aligned almost solely on the film growth direction.
NASA Astrophysics Data System (ADS)
Falak, P.; Hassanzadeh-Tabrizi, S. A.; Saffar-Teluri, A.
2017-11-01
In the present research, a magnetic ZnO-ZnFe2O4 binary nanocomposite was synthesized by a one-step microemulsion method. The characteristics of the synthesized powders were characterized using various analytical instruments including X-ray diffraction, scanning electron microscope, transmission electron microscope, thermogravimetric and differential thermal analysis, vibrating sample magnetometer, and ultraviolet-visible spectroscopy. The results of transmission electron microscope proved that the synthesized nanoparticles have irregular morphologies and the average particle size is about 20 nm. The photocatalytic investigation of ZnO-ZnFe2O4 nanoparticles was carried out using methylene blue solution under UV light. The synthesized nanoparticles showed enhanced photocatalytic performance in comparison with the ZnO nanoparticles more than 40%. The magnetization saturation value of ZnO-ZnFe2O4 nanoparticles was about 5.8 emu/g, which was high enough to be magnetically removed by applying a magnetic field. The results showed that the magnetization and coercivity of the samples reduced by increasing calcination temperature.
Preparation and characterization of V/TiO{sub 2} nanocatalyst with magnetic nucleus of iron
DOE Office of Scientific and Technical Information (OSTI.GOV)
Feyzi, Mostafa; Rafiee, Hamid Reza, E-mail: rafieehr@yahoo.com; Ranjbar, Shahram
2013-11-15
Graphical abstract: - Highlights: • Fe-V/TiO{sub 2} nanocatalyst is prepared. • Combination of sol–gel and wetness impregnation methods. • Facile separation of catalyst from medium by magnet. - Abstract: A magnetic composite containing V/TiO{sub 2} was prepared by combination of sol–gel and wetness impregnation methods. The effects of synthesis temperature, different weight percents of Fe supported on TiO{sub 2}, vanadium loading and the heating rate of calcination on the structure and morphology of nanocatalyst were investigated. The optimum conditions for synthesized catalyst were 40 wt.% of Fe, 15 wt.% of V and synthesis temperature equal to 30 °C. Characterization ofmore » catalyst is carried out using XRD, TGA, DSC, SEM, FTIR and N{sub 2} physisorption measurements. The magnetic character of nanocatalyst was measured using VSM, which showed the typical paramagnetic behavior of sample at room temperature with a saturation magnetization value equal to 8.283 emu/g. The nanocatalyst has a particle size about 56 nm and can easily be separated from medium by a magnet.« less
Fe/Si(001) Ferromagnetic Layers: Reactivity, Local Atomic Structure and Magnetism
DOE Office of Scientific and Technical Information (OSTI.GOV)
Lungu, G. A.; Costescu, R. M.; Husanu, M. A.
2011-10-03
Ultrathin ferromagnetic Fe layers on Si(001) have recently been synthesized using the molecular beam epitaxy (MBE) technique, and their structural and magnetic properties, as well as their interface reactivity have been investigated. The study was undertaken as function of the amount of Fe deposited and of substrate temperature. The interface reactivity was characterized by Auger electron spectroscopy (AES). The surface structure was characterized by low-energy electron diffraction (LEED). The magnetism was investigated by magneto-optical Kerr effect (MOKE). A higher deposition temperature stabilizes a better surface ordering, but it also enhances Fe and Si interdiffusion and it therefore decreases the magnetism.more » Despite the rapid disappearance of the long range order with Fe deposition at room temperature, the material exhibits a significant uniaxial in-plane magnetic anisotropy. For the Fe deposition performed at high temperature (500 deg. C), a weak ferromagnetism is still observed, with saturation magnetization of about 10% of the value obtained previously. MOKE studies allowed inferring the main properties of the distinct formed layers.« less
Highly stable multi-anchored magnetic nanoparticles for optical imaging within biofilms
Stone, R. C.; Fellows, B. D.; Qi, B.; ...
2015-08-05
Magnetic nanoparticles are the next tool in medical diagnoses and treatment in many different biomedical applications, including magnetic hyperthermia as alternative treatment for cancer and bacterial infections, as well as the disruption of biofilms. The colloidal stability of the magnetic nanoparticles in a biological environment is crucial for efficient delivery. A surface that can be easily modifiable can also improve the delivery and imaging properties of the magnetic nanoparticle by adding targeting and imaging moieties, providing a platform for additional modification. The strategy presented in this paper includes multiple nitroDOPA anchors for robust binding to the surface tied to themore » same polymer backbone as multiple poly(ethylene oxide) chains for steric stability. This approach provides biocompatibility and enhanced stability in fetal bovine serum (FBS) and phosphate buffer saline (PBS). As a proof of concept, these polymer-particles complexes were then modified with a near infrared dye and utilized in characterizing the integration of magnetic nanoparticles in biofilms. Finally, the work presented in this manuscript describes the synthesis and characterization of a nontoxic platform for the labeling of near IR-dyes for bioimaging.« less
Statistical averaging of marine magnetic anomalies and the aging of oceanic crust.
Blakely, R.J.
1983-01-01
Visual comparison of Mesozoic and Cenozoic magnetic anomalies in the North Pacific suggests that older anomalies contain less short-wavelength information than younger anomalies in this area. To test this observation, magnetic profiles from the North Pacific are examined from crust of three ages: 0-2.1, 29.3-33.1, and 64.9-70.3Ma. For each time period, at least nine profiles were analyzed by 1) calculating the power density spectrum of each profile, 2) averaging the spectra together, and 3) computing a 'recording filter' for each time period by assuming a hypothetical seafloor model. The model assumes that the top of the source is acoustic basement, the source thickness is 0.5km, and the time scale of geomagnetic reversals is according to Ness et al. (1980). The calculated power density spectra of the three recording filters are complex in shape but show an increase of attenuation of short-wavelength information as the crust ages. These results are interpreted using a multilayer model for marine magnetic anomalies in which the upper layer, corresponding to pillow basalt of seismic layer 2A, acts as a source of noise to the magnetic anomalies. As the ocean crust ages, this noisy contribution by the pillow basalts becomes less significant to the anomalies. Consequently, magnetic sources below layer 2A must be faithful recorders of geomagnetic reversals.-AuthorPacific power density spectrum
Spider Silk: From Protein-Rich Gland Fluids to Diverse Biopolymer Fibers
2016-01-06
characterize the protein-rich fluid in the various spider silk producing glands. We have been using a battery of magnetic resonance methods including...solution and solid-state nuclear magnetic resonance (NMR) and micro imaging (MRI) in combination with wide angle and small angle X-ray diffraction...range of magnetic resonance methods. We successfully developed magnetic resonance imaging (MRI) techniques with localized spectroscopy to probe the silk
New soft magnetic amorphous cobalt based alloys with high hysteresis loop linearity
NASA Astrophysics Data System (ADS)
Nosenko, V. K.; Maslov, V. V.; Kochkubey, A. P.; Kirilchuk, V. V.
2008-02-01
The new amorphous Co56÷59(Fe,Ni,Mn)21÷24(Si0.2B0.8)20-based metal alloys (AMA) with high saturation induction (BS>=1T) were developed. Toroidal tape wound magnetic cores made from these AMA after heat-magnetic treatment (HMT) in a reversal field are characterized by high hysteresis loop linearity, minimum effective magnetic permeability and its high field stability in combination with low coercivity Hc (1-3 A/m, 1 kHz). For the most prospecting alloy compositions the value of effective magnetic permeability decreases compared to known alloys up to 550 - 670 units and remains constant in the wide magnetic field range 1100 - 1300 A/m. Maximum remagnetization loop linearity is achieved after optimum HMT in high Ni containing AMAs, which are characterized by the record low squareness ratio values Ks=0.002-0.02 and Hc=1.0 A/m. Magnetic cores made from the new amorphous alloys can be used both in filter chokes of switch-mode power supply units and in matching mini-transformers of telecommunication systems; at that, high efficiency and accuracy of signal transmission including high frequency pulses are ensured under conditions of long-term influence of dc magnetic bias.
Characteristics of Iron Sand Magnetic Material from Bugel Beach, Kulon Progo, Yogyakarta
NASA Astrophysics Data System (ADS)
Fahmiati; Nuryono; Suyanta
2017-02-01
Magnetic material (MM) of iron sands from Bugel Beach, Kulon Progo, Yogyakarta has been prepared and characterized. Magnetic material was separated from iron sands using a permanent magnet followed by treating with sodium hydroxide (NaOH) solution. The magnetic material product was characterized with X-ray Fluorescence, X-ray Diffraction, Fourrier Transform Infrared spectrophotometry, and Vibrating Sample Magnetometer to determine the chemical composition, crystallinity, presence of functional groups and the magnetization, respectively. Results showed that the investigated iron sand contained magnetic materials up to 89.47% (w/w). The main composition of MM included Fe2O3, TiO2, and SiO2, with percentages of 72.6, 7.0, and 10.0%, respectively, and the functional groups of material was dominated with Fe-OH and Fe-O. Treatment with NaOH 4M and NaOH 8M increased the content of Fe2O3 and TiO2, otherwise reduced the concentration of SiO2 and contributed to the improvement of the magnetization from 42.1 to 44.3 emu/g (with 4 M NaOH) and 64.0 emu/g (with 8 M NaOH). Additionally, MM was dominated with mineral of magnetite and contained functional groups of Fe-OH and Fe-O.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Cegla, H. M.; Shelyag, S.; Watson, C. A.
2013-02-15
We outline our techniques to characterize photospheric granulation as an astrophysical noise source. A four-component parameterization of granulation is developed that can be used to reconstruct stellar line asymmetries and radial velocity shifts due to photospheric convective motions. The four components are made up of absorption line profiles calculated for granules, magnetic intergranular lanes, non-magnetic intergranular lanes, and magnetic bright points at disk center. These components are constructed by averaging Fe I 6302 A magnetically sensitive absorption line profiles output from detailed radiative transport calculations of the solar photosphere. Each of the four categories adopted is based on magnetic fieldmore » and continuum intensity limits determined from examining three-dimensional magnetohydrodynamic simulations with an average magnetic flux of 200 G. Using these four-component line profiles we accurately reconstruct granulation profiles, produced from modeling 12 Multiplication-Sign 12 Mm{sup 2} areas on the solar surface, to within {approx} {+-}20 cm s{sup -1} on a {approx}100 m s{sup -1} granulation signal. We have also successfully reconstructed granulation profiles from a 50 G simulation using the parameterized line profiles from the 200 G average magnetic field simulation. This test demonstrates applicability of the characterization to a range of magnetic stellar activity levels.« less
Cr-doped TiSe 2 - A layered dichalcogenide spin glass
Luo, Huixia; Tao, Jing; Krizan, Jason W.; ...
2015-09-17
We report the magnetic characterization of the Cr-doped layered dichalcogenide TiSe 2. The temperature dependent magnetic susceptibilities are typical of those seen in geometrically frustrated insulating antiferromagnets. The Cr moment is close to the spin-only value, and the Curie–Weiss temperatures (θ cw) are between –90 and –230 K. Freezing of the spin system, which is glassy, characterized by peaks in the ac and dc susceptibility and specific heat, does not occur until below T/θ cw = 0.05. The CDW transition seen in the resistivity for pure TiSe 2 is still present for 3% Cr substitution but is absent by 10%more » substitution, above which the materials are metallic and p-type. Structural refinements, magnetic characterization, and chemical considerations indicate that the materials are of the type Ti 1–xCr xSe 2-x/2 for 0 ≤ x ≤ 0.6.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Gregory, D.M.; Gerald, R.E.; Cody, G.D.
1997-04-01
Magnetic resonance microscopy (MRM) techniques have been employed to study the molecular architectures and properties of structural polymers, fossil fuels, microporous carbons and inorganic catalysts.
Insertion devices for Doris III
DOE Office of Scientific and Technical Information (OSTI.GOV)
Pfluger, J.; Heintze, G.; Baran, W.
1992-01-01
In this paper the mechanical and magnetic layout of the first three insertion devices for DORIS III, an upgraded reconstruction of DORIS II, is described and results of the magnetic characterization are given as well.
NASA Astrophysics Data System (ADS)
Dey, Chaitali; Chaudhuri, Arka; Goswami, Madhuri Mandal
2018-04-01
Herein, we report the synthesis of manganese ferrite (MnFe2O4) magnetic nano hollow sphere (NHS) by a solvothermal route. Crystalline phase was confirmed by X-ray diffraction (XRD), energy dispersive x-ray (EDX). Magnetic measurements were done in vibrating sample magnetometer (VSM) and morphological structure was analyzed by field emission high resolution scanning electron microscope (FESEM) and structural characterization was confirmed by Fourier transform infrared spectroscopy (FTIR), thermal analysis was performed by thermo-gravimetric analysis-differential thermal analysis (TGA-DTA). The size of the NHS was around 470 nm, this large size may show a potential applicability in industrial application, like dye adsorption, catalysis etc. In addition, because of its ferromagnetic character at room temperature, it can be easily separated by external magnetic field after the application is done.
NASA Technical Reports Server (NTRS)
Roth, Don J.
1991-01-01
The purpose of this dissertation was the following: (1) to characterize the effect of pore fraction on a comprehensive set of electrical and magnetic properties for the yttrium-barium-copper-oxide (YBCO) high temperature ceramic superconductor; and (2) to determine the viability of using a room-temperature, nondestructive characterization method to aid in the prediction of superconducting (cryogenic) properties. The latter involved correlating ultrasonic velocity measurements at room temperature with property-affecting pore fraction and oxygen content variations. The use of ultrasonic velocity for estimating pore fraction in YBCO is presented, and other polycrystalline materials are reviewed, modeled, and statistically analyzed. This provides the basis for using ultrasonic velocity to interrogate microstructure. The effect of pore fraction (0.10-0.25) on superconductor properties of YBCO samples was characterized. Spatial (within-sample) variations in microstructure and superconductor properties were investigated, and the effect of oxygen content on elastic behavior was examined. Experimental methods used included a.c. susceptibility, electrical, and ultrasonic velocity measurements. Superconductor properties measured included transition temperature, magnetic transition width, transport and magnetic critical current density, magnetic shielding, a.c. loss, and sharpness of the voltage-current characteristics. An ultrasonic velocity image constructed from measurements at 1mm increments across a YBCO sample revealed microstructural variations that correlated with variations in magnetic shielding and a.c. loss behavior. Destructive examination using quantitative image analysis revealed pore fraction to be the varying microstructural feature.
NASA Technical Reports Server (NTRS)
Kamhawi, Hani; Huang, Wensheng; Haag, Thomas; Shastry, Rohit; Thomas, Robert; Yim, John; Herman, Daniel; Williams, George; Myers, James; Hofer, Richard;
2015-01-01
NASA's Space Technology Mission Directorate (STMD) Solar Electric Propulsion Technology Demonstration Mission (SEP/TDM) project is funding the development of a 12.5-kW Hall thruster system to support future NASA missions. The thruster designated Hall Effect Rocket with Magnetic Shielding (HERMeS) is a 12.5-kW Hall thruster with magnetic shielding incorporating a centrally mounted cathode. HERMeS was designed and modeled by a NASA GRC and JPL team and was fabricated and tested in vacuum facility 5 (VF5) at NASA GRC. Tests at NASA GRC were performed with the Technology Development Unit 1 (TDU1) thruster. TDU1's magnetic shielding topology was confirmed by measurement of anode potential and low electron temperature along the discharge chamber walls. Thermal characterization tests indicated that during full power thruster operation at peak magnetic field strength, the various thruster component temperatures were below prescribed maximum allowable limits. Performance characterization tests demonstrated the thruster's wide throttling range and found that the thruster can achieve a peak thruster efficiency of 63% at 12.5 kW 500 V and can attain a specific impulse of 3,000 s at 12.5 kW and a discharge voltage of 800 V. Facility background pressure variation tests revealed that the performance, operational characteristics, and magnetic shielding effectiveness of the TDU1 design were mostly insensitive to increases in background pressure.
Gold-magnetite nanoparticle-biomolecule conjugates: Synthesis, properties and toxicity studies
NASA Astrophysics Data System (ADS)
Pariti, Akshay
This thesis study focuses on synthesizing and characterizing gold-magnetite optically active magnetic nanoparticle and its conjugation with biomolecules for biomedical applications, especially magnetic fluid hyperthermia treatment for cancerous tissue. Gold nanoparticles have already displayed their potential in the biomedical field. They exhibit excellent optical properties and possess strong surface chemistry which renders them suitable for various biomolecule attachments. Studies have showed gold nanoparticles to be a perfect biocompatible vector. However, clinical trials for gold mediated drug delivery and treatment studied in rat models identified some problems. Of these problems, the low retention time in bloodstream and inability to maneuver externally has been the consequential. To further enhance their potential applications and overcome the problems faced in using gold nanoparticles alone, many researchers have synthesized multifunctional magnetic materials with gold at one terminal. Magnetite, among the investigated magnetic materials is a promising and reliable candidate because of its high magnetic saturation moment and low toxicity. This thesis showcases a simple and facile one pot synthesis of gold-magnetite nanoparticles with an average particle size of 80 nm through hot injection method. The as-synthesized nanoparticles were characterized by XRD, TEM, Mossbauer spectroscopy, SQUID and MTS toxicity studies. The superparamagnetism of the as-synthesized nanoparticles has an interestingly high saturation magnetization moment and low toxicity than the literature values reported earlier. L-cysteine and (-)-EGCG (epigallacatechin-3-gallate) were attached to this multifunctional nanoparticles through the gold terminal and characterized to show the particles applicability through Raman, FTIR and UV-Vis spectroscopy.
Optical and magnetic characterization of theranostic magnetite particles (Conference Presentation)
NASA Astrophysics Data System (ADS)
Cialla-May, Dana; Patze, Sophie; Mueller, Robert; Weber, Karina; Popp, Jürgen
2017-02-01
Magnetic nanoparticles (MNPs) have a major role as contrast agent in diagnostic imaging and therapeutic monitoring. In order to research on MNP exposition, degradation and elimination of those nano composites as well as the consequences of the MNP exposition in relation with social economic relevant diseases (cancer, infectious diseases), the comprehensive characterization of magnetic and structural properties is of high importance. Within this contribution, the magnetic characterization of theranostic relevant MNPs is introduced. Applying a vibrating sample magnetometer (VSM), it is found, that the nanocomposites show superparamagnetic behavior and the recorded data confirm iron oxide cores (magnetite/maghemite). Employing Raman spectroscopy, the typical fingerprint information of magnetite is detected. By increasing the laser power, the transition to maghemite and hematite due to the oxidation of the magnetic core is illustrated. Moreover, IR spectroscopy is applied to characterize the coating material e.g. starch or other biocompatible polymers. To determine the stability of MNPs as well as the MNP's elimination under physiological conditions, different buffer systems were tested i.e. simulated body fluid (SBF) and artificial lysosomal fluid (ALF). The investigated MNPs are stable in SBF; thus, the stability in blood after injection of the contrast agent is guaranteed. Finally, the storage in ALF leads to a complete decomposition of the MNPs, which reflects the conditions in lysosomes and guarantee for a fast MNP elimination. Acknowledgement: We thank the Federal Ministry of Education and Research (BMBF), Germany as well as the Project Management Jülich (PTJ), Germany for funding the research project NanoBEL (03XP0003F).
NASA Astrophysics Data System (ADS)
Konyala, Divya
The research study focused on synthesis, characterization and applications of Fe3O4 core-shelled magnetic nanomaterials. This Fe3O4 magnetic nanomaterials will be prepared by using cost effective and convenient wet-chemistry method and will encapsulated using aqueous extracts of medicinal natural products. Three natural products namely Symplocos racemosa, Picrorhiza kurroa and Butea monosperma used to encapsulate Fe3O 4 MNMs due to their scope to reduce the risk of cancer, improves health, increase energy and enhance the immunity. These three medicinal natural products are synthesize by using water as a solvents to derive its active constituents, which will further used to functionalize the magnetic nanomaterials. The magnetic nanoparticles characterization studies performed using X-ray powder diffraction, Scanning electron microscope, Transmission electron microscope, Ultraviolet-visible spectroscopy, Fourier Transform Infrared spectroscopy (FT-IR) and Magnetic property. Fe3O4 magnetic nanomaterials biological activity was tested on Gram-negative bacteria (Escherichia coli). The results pointed out that, due to the adequate coating of Fe 3O4 (Iron Oxide) core by the medicinal chemical constituents from the natural products, the absorption of Fe3O4 magnetic nanomaterials was not detected in the UV-VIS Spectroscopy. TEM images showed that Fe3O4 coated with natural product extract in core-shelled structure, and the size of the particle ranges from 6 nm to 10 nm. Fourier Transform Infrared spectroscopy (FT-IR) was performed to determine the nature of chemicals present in natural extracts and functionalized Fe3O 4 magnetic nanomaterials. The model of wound healing mimic and antibacterial activity performed on gram-negative (Escherichia coli), indicating steady increasing cell growth after adding Fe3O4 MNMs. It was also found that MNMs synthesized at high temperatures shows less wound healing activity, when compared to MNMs prepared at room temperature due to formation of clusters at high temperatures.
Cardiac remodeling and dysfunction in childhood obesity: a cardiovascular magnetic resonance study.
Jing, Linyuan; Binkley, Cassi M; Suever, Jonathan D; Umasankar, Nivedita; Haggerty, Christopher M; Rich, Jennifer; Wehner, Gregory J; Hamlet, Sean M; Powell, David K; Radulescu, Aurelia; Kirchner, H Lester; Epstein, Frederick H; Fornwalt, Brandon K
2016-05-11
Obesity affects nearly one in five children and is associated with increased risk of premature death. Obesity-related heart disease contributes to premature death. We aimed to use cardiovascular magnetic resonance (CMR) to comprehensively characterize the changes in cardiac geometry and function in obese children. Forty-one obese/overweight (age 12 ± 3 years, 56 % female) and 29 healthy weight children (age 14 ± 3 years, 41 % female) underwent CMR, including both standard cine imaging and displacement encoded imaging, for a complete assessment of left ventricular (LV) structure and function. After adjusting for age, LV mass index was 23 % greater (27 ± 4 g/m(2.7) vs 22 ± 3 g/m(2.7), p <0.001) and the LV myocardium was 10 % thicker (5.6 ± 0.8 mm vs 5.1 ± 0.8 mm, p <0.001) in the obese/overweight children. This evidence of cardiac remodeling was present in obese children as young as age 8. Twenty four percent of obese/overweight children had concentric hypertrophy, 59 % had normal geometry and 17 % had either eccentric hypertrophy or concentric remodeling. LV mass index, thickness, ejection fraction and peak longitudinal and circumferential strains all correlated with epicardial adipose tissue after adjusting for height and gender (all p <0.05). Peak longitudinal and circumferential strains showed a significant relationship with the type of LV remodeling, and were most impaired in children with concentric hypertrophy (p <0.001 and p = 0.003, respectively). Obese children show evidence of significant cardiac remodeling and dysfunction, which begins as young as age 8. Obese children with concentric hypertrophy and impaired strain may represent a particularly high risk subgroup that demands further investigation.
Magnetic Measurements of Atmospheric Dust Deposition in Soils
NASA Astrophysics Data System (ADS)
Kapička, Aleš; Petrovský, Eduard; Grison, Hana; Podrázský, Vilém; Křížek, Pavel
2010-05-01
Atmospheric dust of anthropogenic origin contains significant portion of minerals characterized by ferrimagnetic properties [1,2]. These minerals, mostly iron oxides, can serve as tracers of industrial pollutants in soil layers. Moreover, recent results, e.g., [3,4] show significant correlation between concentration-dependent magnetic parameters (e.g., low-field magnetic susceptibility) and concentration of heavy metals (e.g., Pb, Zn, Cd). In our paper we have investigated magnetic properties of depth soil profiles from Krušné hory Mountains (Czech Republic), which belong to a highly contaminated, so-called Black Triangle in central Europe. Emissions are determined by considerable concentration of big sources of pollution (power plants burning fossil fuel, metallurgical and chemical industry). Increased values of magnetic susceptibility (25 - 200 × 10-5 SI) were clearly identified in the top-soil layers. Thermomagnetic analyses and SEM observation indicate that the accumulated anthropogenic ferrimagnetics dominate these layers. Magnetic enhancement is limited to depths of 4-7 cm below the soil surface, usually in F-H or top of Ah soil horizons; deeper soil horizons contain mainly magnetically weak materials and are characterized by much lower values of susceptibility (up to 30 × 10-5 SI). Significant magnetic parameters (e.g., Curie temperature Tc) and SEM results of contaminated topsoils are comparable with magnetic parameters of atmospheric dust, collected (using high-volume samplers) at the same localities.
Durlak, Wojciech; Herman-Sucharska, Izabela; Urbanik, Andrzej; Klimek, Małgorzata; Karcz, Paulina; Dutkowska, Grażyna; Nitecka, Magdalena; Kwinta, Przemko
2016-01-01
Very low birth weight is associated with long term neurodevelopmental complications. Macroscopic brain abnormalities in prematurity survivors have been investigated in several studies. However, there is limited data regarding local cerebral metabolic status and neurodevelopmental outcomes. The purpose of this study was to characterize the relationship between proton magnetic resonance spectra in basal ganglia, frontal white matter and frontoinsular gray matter, neurodevelopmental outcomes assessed with the Leiter scale and the Developmental Test of Visual Perception and selected socioeconomic variables in a cohort of very low birth weight children at the age of four. Children were divided in three groups based on the severity of neurodevelopmental impairment. There were no differences in spectroscopy in basal ganglia and frontal white matter between the groups. Lower concentrations of N-acetylaspartate (NAA), choline (Cho) and myoinositol (mI) were observed in the frontoinsular cortex of the left hemisphere in children with neurodevelopmental impairment compared to children with normal neurodevelopmental outcomes. Higher parental education, daycare attendance and breastfeeding after birth were associated with more favorable neurodevelopmental prognosis, whereas rural residence was more prevalent in children with moderate and severe impairment. Our study demonstrates the role of long term neurometabolic disruption in the left frontoinsular cortex and selected socioeconomic variables in determination of neurodevelopmental prognosis in prematurity survivors.
Beckmann, Nicolau; Doelemeyer, Arno; Zurbruegg, Stefan; Bigot, Karine; Theil, Diethilde; Frieauff, Wilfried; Kolly, Carine; Moulin, Pierre; Neddermann, Daniel; Kreutzer, Robert; Perrot, Ludovic; Brzak, Irena; Jacobson, Laura H; Staufenbiel, Matthias; Neumann, Ulf; Shimshek, Derya R
2016-09-01
Currently, several immunotherapies and BACE (Beta Site APP Cleaving Enzyme) inhibitor approaches are being tested in the clinic for the treatment of Alzheimer's disease. A crucial mechanism-related safety concern is the exacerbation of microhemorrhages, which are already present in the majority of Alzheimer patients. To investigate potential safety liabilities of long-term BACE inhibitor therapy, we used aged amyloid precursor protein (APP) transgenic mice (APP23), which robustly develop cerebral amyloid angiopathy. T2*-weighted magnetic resonance imaging (MRI), a translational method applicable in preclinical and clinical studies, was used for the detection of microhemorrhages throughout the entire brain, with subsequent histological validation. Three-dimensional reconstruction based on in vivo MRI and serial Perls' stained sections demonstrated a one-to-one matching of the lesions thus allowing for their histopathological characterization. MRI detected small Perls' positive areas with a high spatial resolution. Our data demonstrate that volumetric assessment by noninvasive MRI is well suited to monitor cerebral microhemorrhages in vivo. Furthermore, 3 months treatment of aged APP23 with the potent BACE-inhibitor NB-360 did not exacerbate microhemorrhages in contrast to Aβ-antibody β1. These results substantiate the safe use of BACE inhibitors regarding microhemorrhages in long-term clinical studies for the treatment of Alzheimer's disease. Copyright © 2016 The Author(s). Published by Elsevier Inc. All rights reserved.
Structural and magnetic characterization of Ti doped cobalt ferrite (CoFe2O4)
NASA Astrophysics Data System (ADS)
Pal, Jaswinder; Kumar, Sunil; Kaur, Randeep; Agrawal, P.; Singh, Mandeep; Singh, Anupinder
2018-05-01
Synthesis of Co1-xTixFe2O4 solid solutions for 0.1≤x≤0.4 using the solid-state-reaction rate has been done. The prepared samples were characterized by using XRD (X-ray diffraction) and SEM (Scanning Electron Microscopy). Magnetic studies have been done using Vibrating Sample Magnetometer (VSM). XRD confirmed that Cobalt Ferrite spinel cubic structure in all prepared samples. The lattice parameter `a' increases with increase in the concentration of Ti. SEM micrograph shows good grain growth in all samples. Magnetic Study reveals that the M-H curves of all the prepared samples taken at room temperature are very well saturated. The maximum value of remnant magnetization (Mr ˜13.9 emu/g) and saturation magnetization (Ms ˜74.4 emu/g) has been observed for x =0.2 sample. Coercivity does not show any regular variation with increase in the molar concentration of Ti in CoFe2O4 at A-site.
NASA Technical Reports Server (NTRS)
Abbe, D.
1984-01-01
CoAl and FeAl compounds are developed along two directions. Magnetic susceptibility and specific heat at low temperature on (NiCo)Al and (CoFe)Al ternary alloys are in good agreement with band calculations. Results on magnetization and specific heat under field at low temperature on nonstoichiometric compounds show clearly the importance of the nearest neighbor effects. In the case of CoAl, the isolated cobalt atoms substituting aluminum are characterized by a Kondo behavior, and, for FeAl, the isolated extra iron atoms are magnetic and polarize the matrix. Moreover, for the two compounds, clusters of higher order play a considerable part in the magnetic properties for CoAl, these clusters also seem to be characterized by a Kondo behavior, for FeAl, these clusters whose moment is higher than in the case of isolated atoms, could be constituted of excess parts of iron atoms.
Magneto-optical characterization of colloidal dispersions. Application to nickel nanoparticles.
Pascu, Oana; Caicedo, José Manuel; Fontcuberta, Josep; Herranz, Gervasi; Roig, Anna
2010-08-03
We report here on a fast magneto-optical characterization method for colloidal liquid dispersions of magnetic nanoparticles. We have applied our methodology to Ni nanoparticles with size equal or below 15 nm synthesized by a ligand stabilized solution-phase synthesis. We have measured the magnetic circular dichroism (MCD) of colloidal dispersions and found that we can probe the intrinsic magnetic properties within a wide concentration range, from 10(-5) up to 10(-2) M, with sensitivity to concentrations below 1 microg/mL of magnetic Ni particles. We found that the measured MCD signal scales up with the concentration thus providing a means of determining the concentration values of highly diluted dispersions. The methodology presented here exhibits large flexibility and versatility and might be suitable to study either fundamental problems related to properties of nanosize particles including surface related effects which are highly relevant for magnetic colloids in biomedical applications or to be applied to in situ testing and integration in production lines.
NASA Astrophysics Data System (ADS)
Pandey, Arun; Bandyopadhyay, M.; Sudhir, Dass; Chakraborty, A.
2017-10-01
Helicon wave heated plasmas are much more efficient in terms of ionization per unit power consumed. A permanent magnet based compact helicon wave heated plasma source is developed in the Institute for Plasma Research, after carefully optimizing the geometry, the frequency of the RF power, and the magnetic field conditions. The HELicon Experiment for Negative ion-I source is the single driver helicon plasma source that is being studied for the development of a large sized, multi-driver negative hydrogen ion source. In this paper, the details about the single driver machine and the results from the characterization of the device are presented. A parametric study at different pressures and magnetic field values using a 13.56 MHz RF source has been carried out in argon plasma, as an initial step towards source characterization. A theoretical model is also presented for the particle and power balance in the plasma. The ambipolar diffusion process taking place in a magnetized helicon plasma is also discussed.
Pandey, Arun; Bandyopadhyay, M; Sudhir, Dass; Chakraborty, A
2017-10-01
Helicon wave heated plasmas are much more efficient in terms of ionization per unit power consumed. A permanent magnet based compact helicon wave heated plasma source is developed in the Institute for Plasma Research, after carefully optimizing the geometry, the frequency of the RF power, and the magnetic field conditions. The HELicon Experiment for Negative ion-I source is the single driver helicon plasma source that is being studied for the development of a large sized, multi-driver negative hydrogen ion source. In this paper, the details about the single driver machine and the results from the characterization of the device are presented. A parametric study at different pressures and magnetic field values using a 13.56 MHz RF source has been carried out in argon plasma, as an initial step towards source characterization. A theoretical model is also presented for the particle and power balance in the plasma. The ambipolar diffusion process taking place in a magnetized helicon plasma is also discussed.
NASA Technical Reports Server (NTRS)
Spear, F. S.; Padovanni, E.
1985-01-01
The purpose was to characterize the oxide mineralogy and petrology of samples collected from Potrillo Maar, New Mexico with the goal of explaining the magnetic anamoly that is observed over this region from remote sensing. Potrillo Maar is a diatreme that has brought rocks from all depths in the crust to the surface almost instantaneously. The samples are therefore thought to be representative of the crust as it exists today below this portion of the Rio Grande Rift. It is generally believed that oxide minerals (magnetite, hematite, etc.) are responsible for the magnetic signature of the crust. The samples from Portillo Maar therefore offer a unique opportunity to examine the magnetic mineralogy of the entire crust. The results indicate that the magnetic anamoly observed over Rio Grande Rift may be consequence of the tectonic activity that caused mylonitization of the rocks and allowed the infiltration of oxidizing fluids.
Optical diagnostics on the Magnetized Shock Experiment (MSX)
NASA Astrophysics Data System (ADS)
Boguski, J. C.; Weber, T. E.; Intrator, T. P.; Smith, R. J.; Dunn, J. P.; Hutchinson, T. M.; Gao, K. W.
2013-10-01
The Magnetized Shock Experiment (MSX) at Los Alamos National Laboratory was built to investigate the physics of high Alfvén Mach number, supercritical, magnetized shocks through the acceleration and subsequent stagnation of a Field Reversed Configuration (FRC) plasmoid against a magnetic mirror and/or plasma target. A suite of optical diagnostics has recently been fielded on MSX to characterize plasma conditions during the formation, acceleration, and stagnation phases of the experiment. CCD-backed streak and framing cameras, and a fiber-based visible light array, provide information regarding FRC shape, velocity, and instability growth. Time-resolved narrow and broadband spectroscopy provides information on pre-shock plasma temperature, impurity levels, shock location, and non-thermal ion distributions within the shock region. Details of the diagnostic design, configuration, and characterization will be presented along with initial results. This work is supported by the Center for Magnetic Self Organization, DoE OFES and NNSA under LANS contract DE-AC52-06NA25369. Approved for public release: LA-UR- 13-25190.
Papaefthymiou, Georgia C.; Wong, Stanislaus S.; Viescas, Arthur J.; ...
2014-11-25
Magnetic and Mössbauer characterization of single crystalline, sub-micron sized Bi₂Fe₄O₉ cubes has been performed using SQUID magnetometry and transmission Mössbauer spectroscopy in the temperature range of 4.2 K ≤ T ≤ 300 K. A broad magnetic phase transition from the paramagnetic to the anti-ferromagnetic state is observed below 250 K, with the Mössbauer spectra exhibiting a superposition of magnetic, collapsed and quadrupolar spectra in the transition region of 200 K < T < 245 K. Room temperature Mössbauer spectra obtained in transmission geometry are identical to those recorded in back-scattering geometry via conversion electron Mössbauer spectroscopy, indicating the absence ofmore » strain at the surface. A small hysteresis loop is observed in SQUID measurements at 5 K, attributable to the presence of weak-ferromagnetism arising from the canting of Fe³⁺ ion sublattices in the antiferromagnetic matrix.« less
Synthesis, characterization, applications, and challenges of iron oxide nanoparticles
Ali, Attarad; Zafar, Hira; Zia, Muhammad; ul Haq, Ihsan; Phull, Abdul Rehman; Ali, Joham Sarfraz; Hussain, Altaf
2016-01-01
Recently, iron oxide nanoparticles (NPs) have attracted much consideration due to their unique properties, such as superparamagnetism, surface-to-volume ratio, greater surface area, and easy separation methodology. Various physical, chemical, and biological methods have been adopted to synthesize magnetic NPs with suitable surface chemistry. This review summarizes the methods for the preparation of iron oxide NPs, size and morphology control, and magnetic properties with recent bioengineering, commercial, and industrial applications. Iron oxides exhibit great potential in the fields of life sciences such as biomedicine, agriculture, and environment. Nontoxic conduct and biocompatible applications of magnetic NPs can be enriched further by special surface coating with organic or inorganic molecules, including surfactants, drugs, proteins, starches, enzymes, antibodies, nucleotides, nonionic detergents, and polyelectrolytes. Magnetic NPs can also be directed to an organ, tissue, or tumor using an external magnetic field for hyperthermic treatment of patients. Keeping in mind the current interest in iron NPs, this review is designed to report recent information from synthesis to characterization, and applications of iron NPs. PMID:27578966
NASA Astrophysics Data System (ADS)
Jean, Amandine; Mathé, Pierre-Etienne; Beauvais, Anicet; Chardon, Dominique; Demory, François; Janwari, Shazia
2017-04-01
The western continental passive margin of Peninsular India is fringed by an escarpment, the Western Ghats escarpment (WGE), which separates a narrow coastal lowland plain drained to the west from a highland plateau drained to the east. Since Deccan Traps emplacement, the combined effects of chemical alteration and mechanical erosion led to the formation and dissection of lateritic landscapes whose relicts are preserved both sides of the WGE. Ar-Ar ages of K-rich manganese oxides (cryptomelane) sampled in the lateritic profile of each paleolandscape element have documented the weathering history and put constraints on the paleoclimatic and denudation history of Peninsular India [1,2]. The results have documented intense lateritic weathering during the Eocene (ca. 53-45 Ma) on either sides of the escarpment. Here, we present new independent constraints on the age of that weathering based on paleomagnetism of ferricretes included in thick lateritic weathering mantles of the coastal lowland plain. Our method is based on the paleomagnetic properties of Fe-oxy-hydroxides crystallized in situ in the lateritic weathering profile. The major magnetic minerals, hematite and goethite, have been analyzed by combining hysteresis and remanent magnetizations together with magnetic susceptibility measurements including thermomagnetic curves (KT curves). The main carrier of Natural Remanent Magnetization (NRM) at low temperature is a well-crystallized goethite of first generation characterized by sharp Neel temperature, Tn, at 85°C on KT curves; late goethite generations with distributed Tn below diurnal temperatures (< 65°C) are unable to keep stable NRM. At higher temperature, the component carried by primary and neoformed hematite mimics the primary goethite component. The derived paleopole fits the APWP of India at paleolatitude of 62.3° (with alpha95=5.2°) suggesting an age of ca. 52 Ma [3]. The reverse polarity systematically observed may be ascribed to Chron 23 [4] that refines the paleomagnetic age of the primary goethite to 51.9 - 52.2 Ma. This new age is in agreement with previously obtained Ar-Ar ages in the same weathering mantle upslope the pediment occupying the lowland. These results imply together that the lateritic pediment formed at the foot of the WGE is old, and further attest for very limited denudation of the coastal lowland plain confirming the great stability of the escarpment since at least 50 Ma, despite the negative anomaly of the geoid observed at this latitude. These results have major implications for the Cenozoic topographic evolution of the western continental margin of India, which underwent negligible relief rejuvenation or positive epeirogeny over the last 50 Ma. [1] Bonnet et al., 2016, Chemical Geology 446, 33-53. [2] Beauvais et al., 2016, Geology 44, 299-292. [3] Besse & Courtillot, 1991, J. Geophys. Research 96, 4029-4050 [4] Cande & Kent, 1995, Geomag. Paleomag. Mar. Geol. Geophys. 100, 6093-6095.
NASA Astrophysics Data System (ADS)
Sun, J.; Li, Y.
2017-12-01
Magnetic data contain important information about the subsurface rocks that were magnetized in the geological history, which provides an important avenue to the study of the crustal heterogeneities associated with magmatic and hydrothermal activities. Interpretation of magnetic data has been widely used in mineral exploration, basement characterization and large scale crustal studies for several decades. However, interpreting magnetic data has been often complicated by the presence of remanent magnetizations with unknown magnetization directions. Researchers have developed different methods to deal with the challenges posed by remanence. We have developed a new and effective approach to inverting magnetic data for magnetization vector distributions characterized by region-wise consistency in the magnetization directions. This approach combines the classical Tikhonov inversion scheme with fuzzy C-means clustering algorithm, and constrains the estimated magnetization vectors to a specified small number of possible directions while fitting the observed magnetic data to within noise level. Our magnetization vector inversion recovers both the magnitudes and the directions of the magnetizations in the subsurface. Magnetization directions reflect the unique geological or hydrothermal processes applied to each geological unit, and therefore, can potentially be used for the purpose of differentiating various geological units. We have developed a practically convenient and effective way of assessing the uncertainty associated with the inverted magnetization directions (Figure 1), and investigated how geological differentiation results might be affected (Figure 2). The algorithm and procedures we have developed for magnetization vector inversion and uncertainty analysis open up new possibilities of extracting useful information from magnetic data affected by remanence. We will use a field data example from exploration of an iron-oxide-copper-gold (IOCG) deposit in Brazil to illustrate how to solve the inverse problem, assess uncertainty, and perform geology differentiation in practice. We will also discuss the potential applications of this new method to large scale crustal studies.
NASA Astrophysics Data System (ADS)
Suzuki, M.; Suzuki, I. S.
2004-10-01
Non-equilibrium aging dynamics in 3D Ising spin glass Cu0.5Co0.5Cl2-FeCl3 GBIC has been studied by zero-field cooled (ZFC) magnetization and low frequency AC magnetic susceptibility ( f = 0.05 Hz), where Tg = 3.92 ± 0.11 K. The time dependence of the relaxation rate S( t) = (1/ H)dM_ZFC/dln t for the ZFC magnetization after the ZFC aging protocol, shows a peak at a characteristic time t cr near a wait time t w (aging behavior), corresponding to a crossover from quasi equilibrium dynamics to non-equilibrium. The time t cr strongly depends on t w , temperature ( T), magnetic field ( H), and the temperature shift (Δ T). The rejuvenation effect is observed in both χ^' and χ^'' under the T-shift and H-shift procedures. The memory of the specific spin configurations imprinted during the ZFC aging protocol can be recalled when the system is re-heated at a constant heating rate. The aging, rejuvenation, and memory effects observed in the present system are discussed in terms of the scaling concepts derived from numerical studies on 3D Edwards-Anderson spin glass model.
General organization of the human intra-masseteric aponeuroses: changes with ageing.
Brunel, G; El-Haddioui, A; Bravetti, P; Zouaoui, A; Gaudy, J-F
2003-01-01
A magnetic resonance imaging (MRI) study of the layout of the aponeurotic layers of the masseter muscle was done on a series of 18 patients, aged from 6 to 79 years. The study was undertaken in parallel with a study on 169 cadavers to correlate the anatomical dissection and MRI findings. The aims were as follows. On the cadavers, the results of dissection were compared with the results of MRI: the layer-by-layer dissections and the anatomical dissections of the different spatial planes have shown that the masseter muscle displays a penniform structure typically characterized by the presence of alternating muscular/aponeurotic layers. The anatomical sections and the MRI section in the same plane allowed the appearance of the intra-muscular aponeurotic layers on MRI to be defined. The patients were then divided into four age cohorts, and the arrangement and variations of the human masseter muscle defined as a function of age. This double study has brought new elements to the understanding of the timing of the development of the intra-muscular aponeurotic structures and the modifications which they undergo with ageing. It appears that the aponeurotic structures only become individually identifiable towards the age of 17 years and that ageing is accompanied by a reduction in the transverse muscular mass accompanied by a verticalization of the aponeurotic layers.
NASA Astrophysics Data System (ADS)
Viddal, Candice April Harder
The central concern of this thesis is the study of non-equilibrium behaviour in magnetic materials and its interpretation within the framework of a theoretical model based on the Preisach hypothesis, which decomposes all magnetic materials into a collection of bistable units. More specifically, we have performed comprehensive experimental characterizations of a variety of magnetic materials, including a naturally occurring mineral of nanodimensional titanomagnetite particles embedded in volcanic glass, a compressed powder of nanodimensional magnetite particles immobilized in an organic binder, a thin film of nanodimensional Fe particles embedded in alumina, and a series of sintered, bond-disordered CaxSr1-xRuO3 ferromagnets. We have measured (a) the initial magnetizing curve, the magnetizing remanence, the descending branch of the major hysteresis loop and the demagnetizing remanence as a function of applied field over a broad range of temperatures, (b) the field cooled moment, the zero field cooled moment, the thermoremanent moment and the isothermal remanent moment as a function of temperature in a broad range of applied fields, and (c) viscosity isotherms in a series of negative holding fields following recoil from positive saturation as a function of time over a wide range of temperatures. The measurements were compared with numerical simulations based on a Preisach model ensemble of thermally activated two-level subsystems, characterized individually by a double well free energy profile in a two-dimensional configuration space, an elementary moment reversal, a dissipation field and a bias field, and characterized collectively by a distribution of these characteristic fields. Our efforts were concentrated on two principal spheres of investigation. (1) By performing detailed numerical simulations of the relaxation response of model Preisach collections of two-level subsystems under the same field and temperature protocols used to probe experimentally the relaxation dynamics of spin glasses, we have been able to show that aging, memory and rejuvenation effects are not unique to collectively ordered materials with spin glass correlations, but rather are an ubiquitous feature of materials with a broad distribution of energy barriers where relaxation proceeds as a superposition of independent overbarrier activation events, each with its own characteristic relaxation time constant. (2) The second line of inquiry pertains to probing the two principal mechanisms, thermal fluctuations and barrier growth, which are jointly responsible for shaping the measured temperature dependence of the magnetic properties of all magnetic materials which exhibit a history dependent response to an external field excitation. We have proposed a general strategy for isolating and quantifying these two mechanisms which is based on the analysis of viscosity isotherms and, in particular, on a plot of T ln(tr/tau0) versus Ha, where t r is the time at which a viscosity isotherm measured in a field H a at temperature T reverses sign. When the magnetic response is dominated by thermal activation events, this plot will yield a universal curve from which it is possible to extract the mean elementary moment reversal and to reconstruct the distribution of metastable state excitation energies. When barrier growth dominates, the plot fractures into a family of isothermal curves from which it is, in principle, possible to reconstruct the evolution of the free energy landscape with temperature and to observe the collapse of the barriers as the material is warmed through the critical ordering temperature. The strategy is applied to the analysis of all four materials listed above.
Geomagnetic paleointensity dating of South China Sea sediments for the last 130 kyr
NASA Astrophysics Data System (ADS)
Xiaoqiang, Yang; Heller, Friedrich; Nengyou, Wu; Jie, Yang; Zhihua, Su
2009-06-01
Relative paleointensity records from the northern South China Sea, northwest Pacific Ocean were studied in two gravity piston cores. Continuous mineral magnetic and paleomagnetic measurements were made using discrete sediment samples. Detailed rock magnetic parameters, such as thermomagnetic and high-field hysteresis data, indicate that pseudo-single domain magnetite in a narrow range of grain-size and concentration is the main contributor to the remanent magnetization. The uniform magnetic mineralogy meets the commonly accepted criteria for establishing relative paleointensity records. The relative paleointensity (RPI) curves were constructed by normalizing the natural remanent magnetization (NRM) with isothermal remanent magnetization (IRM), both in the 20-60 mT demagnetization state. Dating constraints have been provided by radiocarbon ages in the upper 400 cm of both cores. Furthermore, we have correlated our paleointensity records with NAPIS-75, S.Atlantic-1089, Sint-200 and NOPAPIS-250 to determine the chronological RPI framework for the South China Sea (SCS-PIS). Although some temporal offsets of paleointensity features between the different records have been recognized, their similar shape suggests that relative paleointensity on the 10 3-10 4 year scale is globally coherent and can provide an age framework for sediments independent of δ18O ages.
Radiological imaging detection of tumors localized in fossa cranii posterior.
Kabashi, Serbeze; Muçaj, Sefedin; Ahmetgjekaj, Ilir; Gashi, Sanije; Fazliu, Ilir; Dreshaj, Shemsedin; Shala, Nexhmedin
2008-01-01
Intracranial tumors are characterized by a variety imaging aspects and their detection is always a challenge. Clinical application of Magnetic Resonance Imaging (MRI) and Computerized Tomography has provided an earlier detection and treatment of many CNS pathologies. The aim of this study is to estimate the role of CT and MRI in the determination of posterior fossa tumors. During period 2000-2005 in UCCK-Prishtina, 368 patients were diagnosed with intracranial tumors. Fifty-nine of them were found to have tumor localized in fossa crani posterior (FCP) without any significant difference between genders (50.8% female vs. 49.2% male, chi2 test=0.02 p=0.896). The average age of patients with FCP tumors was 33.1 (SD +/- 22.5, rank 1-70). The most of these patients were registered in 2003 (20.3%) whereas the least in 2000 (11.9%). The most affected age-group was 0-9 (25.4%) and 50-59 (23.7%) whereas the incidences was between 30-39 years of age (3.4%). Tumor types that more often were found in young's individuals were: Astrocytomas with a peak incidence in teenagers (average age was 12-year-old SD +/- 7.5, rank 3-23), next was Medulloblastomas (average age was 11-years-old, SD +/- 2.9, rank 6-16 years) and ependymomas (average age was 6.8-years-old, SD +/- 4.6, rank 1-12). Patients with osseous tumors are characterized by older age than median (61.0, SD +/- 4.2, rank 58-64), then metastases (53.0, SD +/- 5.3, rank 45-60) and meningiomas (50.8, SD +/- 7.7, rank 38-63). The overall average mortality was 0.41 cases per 100,000 inhabitants with variations through years from 0.30-0.50/100,000 inhabitants. Comparing with other countries, for some types of FCP tumors, lower morbidity is shown in Kosova, with mean incidence 0.41/100,000. The most frequent tumors in children were medulloblastomas, brainstem gliomas, astrocytomas and ependymomas whereas meningiomas and metastasis were most often found in adults. For FCP tumors detection, MRI had 100% sensitivity, specificity and predictive positive value, whereas brain CT was characterized by 95% sensitivity, 90.4 % specificity and 91% predictive positive value.
Magnetic fields of young solar twins
NASA Astrophysics Data System (ADS)
Rosén, L.; Kochukhov, O.; Hackman, T.; Lehtinen, J.
2016-09-01
Aims: The goal of this work is to study the magnetic fields of six young solar-analogue stars both individually, and collectively, to search for possible magnetic field trends with age. If such trends are found, they can be used to understand magnetism in the context of stellar evolution of solar-like stars and to understand the past of the Sun and the solar system. This is also important for the atmospheric evolution of the inner planets, Earth in particular. Methods: We used Stokes IV data from two different spectropolarimeters, NARVAL and HARPSpol. The least-squares deconvolution multi-line technique was used to increase the signal-to-noise ratio of the data. We then applied a modern Zeeman-Doppler imaging code in order to reconstruct the magnetic topology of all stars and the brightness distribution of one of our studied stars. Results: Our results show a significant decrease in the magnetic field strength and energy as the stellar age increases from 100 Myr to 250 Myr, while there is no significant age dependence of the mean magnetic field strength for stars with ages 250-650 Myr. The spread in the mean field strength between different stars is comparable to the scatter between different observations of individual stars. The meridional field component is weaker than the radial and azimuthal field components in 15 of the 16 magnetic maps. It turns out that 89-97% of the magnetic field energy is contained in l = 1 - 3. There is also no clear trend with age and distribution of field energy into poloidal/toroidal and axisymmetric/non-axisymmetric components within the sample. The two oldest stars in this study show an octupole component that is twice as strong as the quadrupole component. This is only seen in 1 of the 13 maps of the younger stars. One star, χ1 Ori, displays two field polarity switches during almost 5 yr of observations suggesting a magnetic cycle length of 2, 6, or 8 yr. Based on observations made with the HARPSpol instrument on the ESO 3.6 m telescope at La Silla (Chile), under the program ID 091.D-0836. Also based on observations obtained at the Bernard Lyot Telescope (TBL, Pic du Midi, France) of the Midi-Pyrénées Observatory, which is operated by the Institut National des Sciences de l'Univers of the Centre National de la Recherche Scientifique of France.
Age and the risk of anaplasia in magnetic resonance-nonenhancing supratentorial cerebral tumors.
Barker, F G; Chang, S M; Huhn, S L; Davis, R L; Gutin, P H; McDermott, M W; Wilson, C B; Prados, M D
1997-09-01
It is often assumed that a cerebral lesion that is nonenhancing on a magnetic resonance imaging study with gadolinium contrast is a low grade tumor. Some physicians recommend observation rather than biopsy for such lesions. The authors prospectively evaluated the incidence of anaplastic tumor histology in a consecutive series of patients who presented to a neuro-oncology service with a nonenhancing mass of the cerebral hemisphere. During a 5-month period, the authors evaluated 31 patients who had a nonenhancing lesion in the cerebral hemisphere on initial magnetic resonance images. Thirty patients underwent stereotactic biopsy (27%) or open resection (73%). The median patient age was 36 years (range, 6-63 years). There was no mortality or permanent neurologic morbidity from surgery. Twenty-eight patients had pathologic confirmation of diagnosis while their lesions were still nonenhancing. Of these patients, 9 (32%) had Grade 3 lesions (anaplastic astrocytoma or oligoastrocytoma), 13 (43%) had Grade 2 lesions (astrocytoma, oligodendroglioma, or oligoastrocytoma), and 2 (7%) had Grade 1 lesions (dysembryoplastic neuroepithelial tumors). Two additional patients (ages 33 and 59 years) who developed enhancement within their lesions during preoperative periods of observation had glioblastomas at surgery. Logistic regression was used to relate patient age to the risk of anaplasia in a nonenhancing cerebral mass lesion. Older age predicted a significantly higher risk of anaplasia (P = 0.025). The model predicted that nonenhancing cerebral masses in patients older than 44 years were more likely to be anaplastic tumors than low grade tumors. There was no "safe" age below which low grade histology could be confidently assumed. Magnetic resonance-nonenhancing cerebral lesions may be histologically anaplastic, even in young patients. The risk of anaplasia in magnetic resonance-nonenhancing lesions increases significantly with patient age.
Amygdala response to faces parallels social behavior in Williams syndrome
Snyder, Abraham Z.; Haist, Frank; Raichle, Marcus E.; Bellugi, Ursula; Stiles, Joan
2009-01-01
Individuals with Williams syndrome (WS), a genetically determined disorder, show relatively strong face-processing abilities despite poor visuospatial skills and depressed intellectual function. Interestingly, beginning early in childhood they also show an unusually high level of interest in face-to-face social interaction. We employed functional magnetic resonance imaging (fMRI) to investigate physiological responses in face-sensitive brain regions, including ventral occipito-temporal cortex and the amygdala, in this unique genetic disorder. Participants included 17 individuals with WS, 17 age- and gender-matched healthy adults (chronological age-matched controls, CA) and 17 typically developing 8- to 9-year-old children (developmental age controls, DA). While engaged in a face discrimination task, WS participants failed to recruit the amygdala, unlike both CA and DA controls. WS fMRI responses in ventral occipito-temporal cortex, however, were comparable to those of DA controls. Given the integral role of the amygdala in social behavior, the failure of WS participants to recruit this region during face processing may be a neural correlate of the abnormally high sociability that characterizes this disorder. PMID:19633063
Neuronal ceroid-lipofuscinosis in longhaired Chihuahuas: clinical, pathologic, and MRI findings.
Nakamoto, Yuya; Yamato, Osamu; Uchida, Kazuyuki; Nibe, Kazumi; Tamura, Shinji; Ozawa, Tsuyoshi; Ueoka, Naotami; Nukaya, Aya; Yabuki, Akira; Nakaichi, Munekazu
2011-01-01
Neuronal ceroid-lipofuscinosis (NCL) is a rare group of inherited neurodegenerative lysosomal storage diseases characterized histopathologically by the abnormal accumulation of ceroid- or lipofuscin-like lipopigments in neurons and other cells throughout the body. The present article describes the clinical, pathologic, and magnetic resonance imaging (MRI) findings of the NCL in three longhaired Chihuahuas between 16 mo and 24 mo of age. Clinical signs, including visual defects and behavioral abnormalities, started between 16 mo and 18 mo of age. Cranial MRI findings in all the dogs were characterized by diffuse severe dilation of the cerebral sulci, dilated fissures of diencephalons, midbrain, and cerebellum, and lateral ventricular enlargement, suggesting atrophy of the forebrain. As the most unusual feature, diffuse meningeal thickening was observed over the entire cerebrum, which was strongly enhanced on contrast T1-weighted images. The dogs' conditions progressed until they each died subsequent to continued neurologic deterioration between 23 mo and 24 mo of age. Histopathologically, there was severe to moderate neuronal cell loss with diffuse astrogliosis throughout the brain. The remaining neuronal cells showed intracytoplasmic accumulation of pale to slightly yellow lipopigments mimicking ceroid or lipofuscin. The thickened meninges consisted of the proliferation of connective tissues with abundant collagen fibers and mild infiltration of inflammatory cells suggesting neuroimmune hyperactivity. Although the etiology of this neuroimmune hyperactivity is not currently known, MRI findings such as meningeal thickening may be a useful diagnostic marker of this variant form of canine NCL.
2014-03-31
stainless steel , 416 stainless steel , 1018 steel , and 8620 steel as these offer structural integrity as well as both magnetic and...corrosion rate of untreated materials such as 304 stainless steel , 416 stainless steel , 1018 steel , 8620 steel . It is believed that the magnetic field...at characterizing the impact of a magnetic field on the corrosion behavior of the selected alloys, namely, 304 austenitic stainless steel
A rare case of short stature: Say Meyer syndrome.
Karthik, T S; Prasad, N Rajendra; Rani, P Radha; Maheshwari, Rushikesh; Reddy, P Amaresh; Chakradhar, B V S; Menon, Bindu
2013-10-01
Say Meyer syndrome is rare X linked condition characterized by developmental delay, short stature and metopic suture synostosis. We are reporting a case of Say Meyer syndrome presented to our hospital for short stature and developmental delay at age 3½ years. A 3½-year-old boy presented to our hospital for decreased growth velocity from the age of 1 year. History revealed the boy had a birth weight of 2.3 kg, had an episode of seizures in the neonatal period. He was born to non-consanguineous marriage. He had global developmental delay and there was a lack of bowel and bladder control. History did not reveal any hearing or visual impairment. No history of any chronic systemic illnesses. Magnetic resonance imaging (MRI) brain revealed mild diffuse frontotemporal atrophy with multiple irregular gliotic areas in bilateral frontal lobes. Diffuse white matter volume loss in bilateral cerebral hemispheres. Diffuse thinning of corpus callosum. Diffuse periventricular hyper intensity on T2W and fluid attenuated inversion recovery sequences. Say Meyer syndrome is rare X linked condition characterized by developmental delay, short stature and metopic suture synostosis. Characteristic MRI brain findings include diffuse frontotemporal atrophy with multiple gliotic areas in frontal lobes. Diffuse white matter volume loss in bilateral cerebral hemispheres.
Geng, J.; Nlebedim, I. C.; Besser, M. F.; ...
2016-04-15
A bulk combinatorial approach for synthesizing alloy libraries using laser engineered net shaping (LENS; i.e., 3D printing) was utilized to rapidly assess material systems for magnetic applications. The LENS system feeds powders in different ratios into a melt pool created by a laser to synthesize samples with bulk (millimeters) dimensions. By analyzing these libraries with autosampler differential scanning calorimeter/thermal gravimetric analysis and vibrating sample magnetometry, we are able to rapidly characterize the thermodynamic and magnetic properties of the libraries. Furthermore, the Fe-Co binary alloy was used as a model system and the results were compared with data in the literature.
A novel field generator for magnetic stimulation in cell culture experiments.
Vogt, G; Schrefl, A; Mitteregger, R; Falkenhagen, D
1997-06-01
A novel field generator specially designed to examine the influence of low frequency magnetic fields on specific cell material was constructed and characterized. The exposure unit described in this paper consists of a controller unit and three sets of coils. The field generator permits a precious definition of the revelant signal parameters and allows the superposition of alternating current (AC) and direct current (DC) magnetic fields. Critical system parameters were monitored continuously. The three sets of coils, each arranged in the Helmholtz Configuration were characterized. After data processing and visualization the results showed a constant and homogeneous field within the experimental area. The special coil design also allows their use in an incubator.
2011-09-26
determine g-factor of the atomic system, it is convenient experimentally to fix 0 and to find the resonance magnetic field Hres corresponding to the...given frequency ( Hres = res/). In ferromagnetic materials, there exist strong internal anisotropic magnetic fields, which are caused by the magnetic
Magnetic holes in the dipolarized magnetotail: ion and electron anisotropies
NASA Astrophysics Data System (ADS)
Shustov, P.; Artemyev, A.; Zhang, X. J.; Yushkov, E.; Petrukovich, A. A.
2017-12-01
We conduct statistics on magnetic holes observed by THEMIS spacecraft in the near-Earth magnetotail. Groups of holes are detected after dipolarizations in the quiet, equatorial plasma sheet. Magnetic holes are characterized by significant magnetic field depressions (up to 50%) and strong electron currents ( 10-50 nA/m2), with spatial scales much smaller than the ion gyroradius. These magnetic holes are populated by hot (>10 keV), transversely anisotropic electrons supporting the pressure balance. We present statistical properties of these sub-ion scale magnetic holes and discuss possible mechanisms on the hole formation.
Magnetic Field Generation and B-Dot Sensor Characterization in the High Frequency Band
2012-03-01
date Dr. Andrew J, Terzuoli, PhD (Member) date Dr. Michael J. Havrilla, PhD (Member) date AFIT/GE/ENG/12-20 Abstract Designing a high frequency ( HF ...large wavelengths in the HF range make it difficult to accurately estimate from which direction a magnetic field is emitting. Accurate DF estimates are...necessary for search and rescue operations and geolocating RF emitters of interest. The primary goal of this research is to characterize the
Imaging Carbon Nanotubes in High Performance Polymer Composites via Magnetic Force Microscope
NASA Technical Reports Server (NTRS)
Lillehei, Peter T.; Park, Cheol; Rouse, Jason H.; Siochi, Emilie J.; Bushnell, Dennis M. (Technical Monitor)
2002-01-01
Application of carbon nanotubes as reinforcement in structural composites is dependent on the efficient dispersion of the nanotubes in a high performance polymer matrix. The characterization of such dispersion is limited by the lack of available tools to visualize the quality of the matrix/carbon nanotube interaction. The work reported herein demonstrates the use of magnetic force microscopy (MFM) as a promising technique for characterizing the dispersion of nanotubes in a high performance polymer matrix.
Synthesis and characterization of ZnS@Fe3O4 fluorescent-magnetic bifunctional nanospheres
NASA Astrophysics Data System (ADS)
Koc, Kenan; Karakus, Baris; Rajar, Kausar; Alveroglu, Esra
2017-10-01
Herein, we synthesized and characterized fluorescent and super paramagnetic ZnS@Fe3O4 nanospheres. First, (3-mercaptopropyl) trimethoxysilane (MPS) capped ZnS quantum dots (QDs) and SiO2 coated Fe3O4 nanoparticles were synthesized separately by using solution growth and co-precipitation techniques. After synthesis and characterization of these two nanoparticles, they were conglutinated together in a nano sized sphere. The QDs were attached to the surface of the Fe3O4 nanoparticles by Sisbnd Osbnd Si bonds and so Sisbnd Osbnd Si bonds created a SiO2 network around the nanoparticles during the formation of the ZnS@Fe3O4 nanospheres. The synthesized MPS capped ZnS fluorescent QDs, SiO2 coated magnetite super paramagnetic nanoparticles and ZnS@Fe3O4 fluorescent-magnetic bifunctional nanospheres were characterized by using UV-Vis Absorption Spectroscopy, Fluorescence Spectroscopy, X-ray analysis, Vibrating Sample Magnetometer analysis, Attenuated Total Reflection-Fourier Transform Infrared Spectroscopy, Scanning Electron Microscope and Energy-dispersive X-ray spectroscopy. ZnS@Fe3O4 bifunctional nanospheres were shown to retain the magnetic properties of magnetite, while exhibiting the luminescent optical properties of ZnS nanoparticles. The combination of fluorescent and magnetic behaviors of nano composites make them useful for potential applications in the field of bio-medical and environmental.
Magnetic molecularly imprinted polymer for aspirin recognition and controlled release
NASA Astrophysics Data System (ADS)
Kan, Xianwen; Geng, Zhirong; Zhao, Yao; Wang, Zhilin; Zhu, Jun-Jie
2009-04-01
Core-shell structural magnetic molecularly imprinted polymers (magnetic MIPs) with combined properties of molecular recognition and controlled release were prepared and characterized. Magnetic MIPs were synthesized by the co-polymerization of methacrylic acid (MAA) and trimethylolpropane trimethacrylate (TRIM) around aspirin (ASP) at the surface of double-bond-functionalized Fe3O4 nanoparticles in chloroform. The obtained spherical magnetic MIPs with diameters of about 500 nm had obvious superparamagnetism and could be separated quickly by an external magnetic field. Binding experiments were carried out to evaluate the properties of magnetic MIPs and magnetic non-molecularly imprinted polymers (magnetic NIPs). The results demonstrated that the magnetic MIPs had high adsorption capacity and selectivity to ASP. Moreover, release profiles and release rate of ASP from the ASP-loaded magnetic MIPs indicated that the magnetic MIPs also had potential applications in drug controlled release.
Parés, J M; Pérez-González, A; Weil, A B; Arsuaga, J L
2000-04-01
We report new paleomagnetic data for the Middle Pleistocene hominid-bearing strata in the Sima de los Huesos, North Spain. Sediments (brown muds with human and bear fossils and the underlying sterile clayey and sandy unit) preserve both normal and reversed magnetic components. The sterile unit has exclusively reversed magnetization, dating back to the Matuyama Chron, and thus is Lower Pleistocene in age. The overlying fossiliferous muds have a dominant normal magnetization that overprints a partially resolved reversed magnetization. These data are compatible with one of the reversal events that occurred during the Brunhes Chron. Combined with the existing U-series dates and evidence from the macro- and microfauna, these paleomagnetic results suggest an age of the hominid fossils between 325 to 205 ka, whereas the underlying sand and silts are older than 780 ka. Copyright 2000 Wiley-Liss, Inc.
Parlett, Lauren E.; Bowman, Joseph D.; van Wijngaarden, Edwin
2015-01-01
Objective Epidemiologic evidence for the association between electromagnetic fields and amyotrophic lateral sclerosis, the most common form of motor neuron disease (MND), has been inconclusive. We evaluated the association between electromagnetic fields and MND among workers in occupations potentially exposed to magnetic fields. Methods MND mortality (ICD-9 335.2) was examined in the National Longitudinal Mortality Study using multivariable proportional hazards models. Occupational exposure to magnetic fields was determined on the basis of a population-based job-exposure matrix. Age at entry, education, race, sex, and income were considered for inclusion as covariates. Results After adjusting for age, sex, and education, there were no increased risks of MND mortality in relation to potential magnetic field exposure, with hazard ratios around the null in all magnetic field exposure quartiles. Conclusions Our study does not provide evidence for an association between magnetic field exposure and MND mortality. PMID:22076040
Pizarro, Ricardo; Nair, Veena; Meier, Timothy; Holdsworth, Ryan; Tunnell, Evelyn; Rutecki, Paul; Sillay, Karl; Meyerand, Mary E; Prabhakaran, Vivek
2016-08-01
Seizure localization includes neuroimaging like electroencephalogram, and magnetic resonance imaging (MRI) with limited ability to characterize the epileptogenic network. Temporal clustering analysis (TCA) characterizes epileptogenic network congruent with interictal epileptiform discharges by clustering together voxels with transient signals. We generated epileptogenic areas for 12 of 13 epilepsy patients with TCA, congruent with different areas of seizure onset. Resting functional MRI (fMRI) scans are noninvasive, and can be acquired quickly, in patients with different levels of severity and function. Analyzing resting fMRI data using TCA is quick and can complement clinical methods to characterize the epileptogenic network.
Direct magnetocaloric characterization and simulation of thermomagnetic cycles
NASA Astrophysics Data System (ADS)
Porcari, G.; Buzzi, M.; Cugini, F.; Pellicelli, R.; Pernechele, C.; Caron, L.; Brück, E.; Solzi, M.
2013-07-01
An experimental setup for the direct measurement of the magnetocaloric effect capable of simulating high frequency magnetothermal cycles on laboratory-scale samples is described. The study of the magnetocaloric properties of working materials under operative conditions is fundamental for the development of innovative devices. Frequency and time dependent characterization can provide essential information on intrinsic features such as magnetic field induced fatigue in materials undergoing first order magnetic phase transitions. A full characterization of the adiabatic temperature change performed for a sample of Gadolinium across its Curie transition shows the good agreement between our results and literature data and in-field differential scanning calorimetry.
In vivo imaging of cortical pathology in multiple sclerosis using ultra-high field MRI
Mainero, C; Benner, T; Radding, A; van der Kouwe, A; Jensen, R; Rosen, B R.; Kinkel, R P.
2009-01-01
Objective: We used ultra-high field MRI to visualize cortical lesion types described by neuropathology in 16 patients with multiple sclerosis (MS) compared with 8 age-matched controls; to characterize the contrast properties of cortical lesions including T2*, T2, T1, and phase images; and to investigate the relationship between cortical lesion types and clinical data. Methods: We collected, on a 7-T scanner, 2-dimensional fast low-angle shot (FLASH)-T2*-weighted spoiled gradient-echo, T2-weighted turbo spin-echo (TSE) images (0.33 × 033 × 1 mm3), and a 3-dimensional magnetization-prepared rapid gradient echo. Results: Overall, 199 cortical lesions were detected in patients on both FLASH-T2* and T2-TSE scans. Seven-tesla MRI allowed for characterization of cortical plaques into type I (leukocortical), type II (intracortical), and type III/IV (subpial extending partly or completely through the cortical width) lesions as described histopathologically. Types III and IV were the most frequent type of cortical plaques (50.2%), followed by type I (36.2%) and type II (13.6%) lesions. Each lesion type was more frequent in secondary progressive than in relapsing–remitting MS. This difference, however, was significant only for type III/IV lesions. T2*-weighted images showed the highest, while phase images showed the lowest, contrast-to-noise ratio for all cortical lesion types. In patients, the number of type III/IV lesions was associated with greater disability (p < 0.02 by Spearman test) and older age (p < 0.04 by Spearman test). Conclusions: Seven-tesla MRI detected different histologic cortical lesion types in our small multiple sclerosis (MS) sample, suggesting, if validated in a larger population, that it may prove a valuable tool to assess the contribution of cortical MS pathology to clinical disability. GLOSSARY ANOVA = analysis of variance; BN = background noise; CNR = contrast-to-noise ratio; DIR = double-inversion recovery; EDSS = Expanded Disability Status Scale; FLAIR = fluid-attenuated inversion recovery; FLASH = fast low-angle shot; GM = gray matter; MPRAGE = magnetization-prepared rapid gradient echo; MR = magnetic resonance; MS = multiple sclerosis; NACGM = normal-appearing cortical gray matter; RF = radiofrequency; ROI = region of interest; RRMS = relapsing–remitting multiple sclerosis; SNR = signal-to-noise ratio; SPMS = secondary progressive multiple sclerosis; TA = time of acquisition; TE = echo time; TR = repetition time; TSE = turbo spin-echo; WM = white matter. PMID:19641168
Cao, Shenglong; Hua, Ya; Keep, Richard F; Chaudhary, Neeraj; Xi, Guohua
2018-04-01
Brain iron overload is a key factor causing brain injury after intracerebral hemorrhage (ICH). This study quantified brain iron levels after ICH with magnetic resonance imaging R2* mapping. The effect of minocycline on iron overload and ICH-induced brain injury in aged rats was also determined. Aged (18 months old) male Fischer 344 rats had an intracerebral injection of autologous blood or saline, and brain iron levels were measured by magnetic resonance imaging R2* mapping. Some ICH rats were treated with minocycline or vehicle. The rats were euthanized at days 7 and 28 after ICH, and brains were used for immunohistochemistry and Western blot analyses. Magnetic resonance imaging (T2-weighted, T2* gradient-echo, and R2* mapping) sequences were performed at different time points. ICH-induced brain iron overload in the perihematomal area could be quantified by R2* mapping. Minocycline treatment reduced brain iron accumulation, T2* lesion volume, iron-handling protein upregulation, neuronal cell death, and neurological deficits ( P <0.05). Magnetic resonance imaging R2* mapping is a reliable and noninvasive method, which can quantitatively measure brain iron levels after ICH. Minocycline reduced ICH-related perihematomal iron accumulation and brain injury in aged rats. © 2018 American Heart Association, Inc.
Mueller, Fred M [Los Alamos, NM; Bronisz, Lawrence [Los Alamos, NM; Grube, Holger [Los Alamos, NM; Nelson, David C [Santa Fe, NM; Mace, Jonathan L [Los Alamos, NM
2006-11-14
A magnetic infrasound sensor is produced by constraining a permanent magnet inside a magnetic potential well above the surface of superconducting material. The magnetic infrasound sensor measures the position or movement of the permanent magnet within the magnetic potential well, and interprets the measurements. Infrasound sources can be located and characterized by combining the measurements from one or more infrasound sensors. The magnetic infrasound sensor can be tuned to match infrasound source types, resulting in better signal-to-noise ratio. The present invention can operate in frequency modulation mode to improve sensitivity and signal-to-noise ratio. In an alternate construction, the superconductor can be levitated over a magnet or magnets. The system can also be driven, so that time resolved perturbations are sensed, resulting in a frequency modulation version with improved sensitivity and signal-to-noise ratio.
Evaluation, development, and characterization of superconducting materials for space application
NASA Technical Reports Server (NTRS)
Thorpe, A. N.
1989-01-01
Results are reported of low magnetic field studies of dc magnetic susceptibility and ac magnetic susceptibility of bulk samples and powders. These data are analyzed and compared with the microstructures and compositions of the samples as determined by scanning electron microscopic micrographs, X-ray and chemical analysis. Particular emphasis is given to the interpretation of the ac magnetic susceptibility data which were obtained as function of the magnitude and frequency of the ac measuring field, and low values of an applied dc magnetic field. Two general conclusions are given and briefly discussed.
Optical fiber magnetic field sensors with TbDyFe magnetostrictive thin films as sensing materials.
Yang, Minghong; Dai, Jixiang; Zhou, Ciming; Jiang, Desheng
2009-11-09
Different from usually-used bulk magnetostrictive materials, magnetostrictive TbDyFe thin films were firstly proposed as sensing materials for fiber-optic magnetic field sensing characterization. By magnetron sputtering process, TbDyFe thin films were deposited on etched side circle of a fiber Bragg Grating (FBG) as sensing element. There exists more than 45pm change of FBG wavelength when magnet field increase up to 50 mT. The response to magnetic field is reversible, and could be applicable for magnetic and current sensing.
Fast Characterization of Magnetic Impurities in Single-Wall Carbon Nanotubes
NASA Technical Reports Server (NTRS)
Chen, Feng; Xue, Y. Y.; Hadijiev, Viktor G.; Chu, C. W.; Nikolaev, Pasha; Arepalli, Sivaram
2003-01-01
We have demonstrated that the magnetic susceptibility measurement is a non-destructive, fast and accurate method to determine the residual metal catalysts in a few microgram single-wall carbon nanotube (SWCNT) sample. We have studied magnetic impurities in raw and purified SWCNT by magnetic susceptibility measurements, transmission electron microscopy, and thermogravimetry. The data suggest that the saturation magnetic moment and the effective field, which is caused by the interparticle interactions, decreases and increases respectively with the decrease of the particle size. Methods are suggested to overcome the uncertainty associated.
Multifunctional biocompatible coatings on magnetic nanoparticles
NASA Astrophysics Data System (ADS)
Bychkova, A. V.; Sorokina, O. N.; Rosenfeld, M. A.; Kovarski, A. L.
2012-11-01
Methods for coating formation on magnetic nanoparticles used in biology and medicine are considered. Key requirements to the coatings are formulated, namely, biocompatibility, stability, the possibility of attachment of pharmaceutical agents, and the absence of toxicity. The behaviour of nanoparticle/coating nanosystems in the body including penetration through cellular membranes and the excretion rates and routes is analyzed. Parameters characterizing the magnetic properties of these systems and their magnetic controllability are described. Factors limiting the applications of magnetically controlled nanosystems for targeted drug delivery are discussed. The bibliography includes 405 references.
Development of a Cryostat to Characterize Nano-scale Superconducting Quantum Interference Devices
NASA Astrophysics Data System (ADS)
Longo, Mathew; Matheny, Matthew; Knudsen, Jasmine
2016-03-01
We have designed and constructed a low-noise vacuum cryostat to be used for the characterization of nano-scale superconducting quantum interference devices (SQUIDs). Such devices are very sensitive to magnetic fields and can measure changes in flux on the order of a single electron magnetic moment. As a part of the design process, we calculated the separation required between the cryogenic preamplifier and superconducting magnet, including a high-permeability magnetic shield, using a finite-element model of the apparatus. The cryostat comprises a vacuum cross at room temperature for filtered DC and shielded RF electrical connections, a thin-wall stainless steel support tube, a taper-sealed cryogenic vacuum can, and internal mechanical support and wiring for the nanoSQUID. The Dewar is modified with a room-temperature flange with a sliding seal for the cryostat. The flange supports the superconducting 3 Tesla magnet and thermometry wiring. Upon completion of the cryostat fabrication and Dewar modifications, operation of the nanoSQUIDs as transported from our collaborator's laboratory in Israel will be confirmed, as the lead forming the SQUID is sensitive to oxidation and the SQUIDs must be shipped in a vacuum container. After operation of the nanoSQUIDs is confirmed, the primary work of characterizing their high-speed properties will begin. This will include looking at the measurement of relaxation oscillations at high bandwidth in comparison to the theoretical predictions of the current model.
Lattice field theory study of magnetic catalysis in graphene
DeTar, Carleton; Winterowd, Christopher; Zafeiropoulos, Savvas
2017-04-15
We discuss the simulation of the low-energy effective field theory (EFT) for graphene in the presence of an external magnetic field. Our fully nonperturbative calculation uses methods of lattice gauge theory to study the theory using a hybrid Monte Carlo approach. We investigate the phenomenon of magnetic catalysis in the context of graphene by studying the chiral condensate which is the order parameter characterizing the spontaneous breaking of chiral symmetry. In the EFT, the symmetry breaking pattern is given bymore » $$U(4) \\to U(2) \\times U(2)$$. We also comment on the difficulty, in this lattice formalism, of studying the time-reversal-odd condensate characterizing the ground state in the presence of a magnetic field. Lastly, we study the mass spectrum of the theory, in particular the Nambu-Goldstone (NG) mode as well as the Dirac quasiparticle, which is predicted to obtain a dynamical mass.« less
Half-metallic ferromagnetism in Sr3Ru2O7
NASA Astrophysics Data System (ADS)
Rivero, Pablo; Meunier, Vincent; Shelton, William
2017-05-01
The bilayered member of the Ruddesden-Popper family of ruthenates, Sr3Ru2O7 , has received increasing attention due to its interesting properties and phases. By using first principle calculations we find that the ground state is characterized by a ferromagnetic (FM) half-metallic state. This state strongly competes with an antiferromagnetic metallic phase, which indicates the possible presence of a particular state characterized by the existence of different magnetic domains. To drive the system towards a phase transition we studied the electronic and magnetic properties as a function of RuO6 octahedra rotations and found that the magnetic phase does not couple with the rotation angle. Our results provide accurate electronic, structure, and magnetic ground-state properties of Sr3Ru2O7 and stimulate the investigation of other types of octahedra rotations and distortions in the search of phase transitions.
NASA Astrophysics Data System (ADS)
Zhao, Aijie; Yao, Peng; Kang, Chunshang; Yuan, Xubo; Chang, Jin; Pu, Peiyu
2005-08-01
This paper describes a new formulation of magnetic nanoparticles coated by a novel polymer matrix—O-carboxylmethylated chitosan (O-CMC) as drug/gene carrier. The O-CMC magnetic nanoparticles were derivatized with a peptide sequence from the HIV-tat protein to improve the translocational property and cellar uptake of the nanoparticles. To evaluate the O-MNPs-tat as drug carriers, MTX was incorporated as a model drug and MTX-loaded O-MNPs-tat with an average diameter of 45-60 nm were prepared and characterized by TEM, AFM and VSM. The cytotoxicity of MTX-loaded O-MNPs-tat was investigated with U-937 tumor cells. The results showed that the MTX-loaded O-MNPs-tat retained significant antitumor toxicity; additionally, sustained release of MTX from O-CMC nanoparticles was observed in vitro, suggesting that the tat-O-MNPs could be a novel magnetic targeting carrier.
NASA Astrophysics Data System (ADS)
Chavan, Apparao R.; Chilwar, R. R.; Shisode, M. V.; Hivrekar, Mahesh M.; Mande, V. K.; Jadhav, K. M.
2018-05-01
The nanocrystalline NiFe2O4 thin film has been prepared using a spray pyrolysis technique on glass substrate. The prepared thin film was characterized by using X-ray diffraction (XRD), Fourier transform Infrared spectroscopy (FTIR), and Field Emission-Scanning Electron Microscopy (FE-SEM) characterization techniques for the structural and microstructural analysis. The magnetic property was measured using vibrating sample magnetometer (VSM) at room temperature. X-ray diffraction studies show the formation of single phase spinel structure of the thin film. The octahedral and tetrahedral vibration in the sample was studied by Fourier transform infrared (FT-IR) spectra. Magnetic hysteresis loop was recorded for thin film at room temperature. At 15 kOe, saturation magnetization (Ms) was found to increase while coercivity (Hc) decreases with thickness of the NiFe2O4 thin film.
NASA Astrophysics Data System (ADS)
Elfgen, S.; Franck, D.; Hameyer, K.
2018-04-01
Magnetic measurements are indispensable for the characterization of soft magnetic material used e.g. in electrical machines. Characteristic values are used as quality control during production and for the parametrization of material models. Uncertainties and errors in the measurements are reflected directly in the parameters of the material models. This can result in over-dimensioning and inaccuracies in simulations for the design of electrical machines. Therefore, existing influencing factors in the characterization of soft magnetic materials are named and their resulting uncertainties contributions studied. The analysis of the resulting uncertainty contributions can serve the operator as additional selection criteria for different measuring sensors. The investigation is performed for measurements within and outside the currently prescribed standard, using a Single sheet tester and its impact on the identification of iron loss parameter is studied.
Omer-Mizrahi, Melany; Margel, Shlomo
2009-01-15
Core polystyrene microspheres of narrow size distribution were prepared by dispersion polymerization of styrene in a mixture of ethanol and 2-methoxy ethanol. Uniform polyglycidyl methacrylate/polystyrene core-shell micrometer-sized particles were prepared by emulsion polymerization at 73 degrees C of glycidyl methacrylate in the presence of the core polystyrene microspheres. Core-shell particles with different properties (size, surface morphology and composition) have been prepared by changing various parameters belonging to the above seeded emulsion polymerization process, e.g., volumes of the monomer glycidyl methacrylate and the crosslinker monomer ethylene glycol dimethacrylate. Magnetic Fe(3)O(4)/polyglycidyl methacrylate/polystyrene micrometer-sized particles were prepared by coating the former core-shell particles with magnetite nanoparticles via a nucleation and growth mechanism. Characterization of the various particles has been accomplished by routine methods such as light microscopy, SEM, FTIR, BET and magnetic measurements.
NASA Astrophysics Data System (ADS)
Bordelon, David E.; Cornejo, Christine; Grüttner, Cordula; Westphal, Fritz; DeWeese, Theodore L.; Ivkov, Robert
2011-06-01
Magnetic nanoparticles can create heat that can be exploited to treat cancer when they are exposed to alternating magnetic fields (AMF). At a fixed frequency, the particle heating efficiency or specific power loss (SPL) depends upon the magnitude of the AMF. We characterized the amplitude-dependent SPL of three commercial dextran-iron oxide nanoparticle suspensions through saturation to 94 kA/m with a calorimeter comprising a solenoid coil that generates a uniform field to 100 kA/m at ˜150 kHz. We also describe a novel method to empirically determine the appropriate range of the heating curve from which the SPL is then calculated. These results agree with SPL values calculated from the phenomenological Box-Lucas equation. We note that the amplitude-dependent SPL among the samples was markedly different, indicating significant magneto-structural variation not anticipated by current models.
Environmental magnetic signature of the Deccan Phase 2 at the Gambsach section
NASA Astrophysics Data System (ADS)
Font, Eric; Adatte, Thierry; Florindo, Fabio
2015-04-01
The age and paleoenvironmental effects of the Deccan Traps volcanism are still poorly constrained. Recently, we discovered an interval of low magnetic susceptibility containing akaganeite in stratigraphic interval located just below the Cretaceous-Tertiary Boundary (KTB) at Bidart and Gubbio and correlated in age to the Deccan Phase 2. Here we aim to test our hypotheses in another complete and well-calibrated KT section, the Gambsach section in Austria. We applied magnetic susceptibility, isothermal remanent magnetization curves and FORC diagrams is order to check for changes in magnetic properties and their link with paleoenvironmental changes. Our results show that an interval of low magnetic susceptibility is located just below the KTB, similarly to Bidart and Gubbio. The low values of magnetic susceptibility correspond to lower content in magnetite and hematite. We interpreted the loss of iron oxides as the result of reductive dissolution due to ocean acidification. The newly found evidences are consistent with major paleoenvironmental changes linked to Deccan volcanism at the dawn of the KT mass extinction. Keywords: Deccan, KT mass extinction, magnetism, environment, Gambsach. Funded by FCT (PTDC/CTE-GIX/117298/2010)
Transverse relaxation in the rotating frame induced by chemical exchange.
Michaeli, Shalom; Sorce, Dennis J; Idiyatullin, Djaudat; Ugurbil, Kamil; Garwood, Michael
2004-08-01
In the presence of radiofrequency irradiation, relaxation of magnetization aligned with the effective magnetic field is characterized by the time constant T1rho. On the other hand, the time constant T2rho characterizes the relaxation of magnetization that is perpendicular to the effective field. Here, it is shown that T2rho can be measured directly with Carr-Purcell sequences composed of a train of adiabatic full-passage (AFP) pulses. During adiabatic rotation, T2rho characterizes the relaxation of the magnetization, which under adiabatic conditions remains approximately perpendicular to the time-dependent effective field. Theory is derived to describe the influence of chemical exchange on T2rho relaxation in the fast-exchange regime, with time constant defined as T2rho,ex. The derived theory predicts the rate constant R2rho,ex (= 1/T2rho,ex) to be dependent on the choice of amplitude- and frequency-modulation functions used in the AFP pulses. Measurements of R2rho,ex of the water/ethanol exchanging system confirm the predicted dependence on modulation functions. The described theoretical framework and adiabatic methods represent new tools to probe exchanging systems. Copyright 2004 Elsevier Inc.
An Analysis of the Rapidly Rotating Bp star HD 133880
NASA Technical Reports Server (NTRS)
Bailey, J. D.; Grunhut, J.; Shultz, M.; Wade, G.; Landstreet, J. D.; Bohlender, D.; Lim, J.; Wong, K.; Drake, S.; Linsky, J.
2012-01-01
HD 133880 is a rapidly rotating chemically peculiar B-type (Bp) star (nu sin i approx = 103km/s) and is host to one of the strongest magnetic fields of any Ap/Bp star. A member of the Upper Centaurus Lupus association, it is a star with a well-determined age of 16 Myr. 12 new spectra, four of which are polarimetric, obtained from the FEROS, ESPaDOnS and HARPS instruments, provide sufficient material from which to re-evaluate the magnetic field and obtain a first approximation to the atmospheric abundance distributions of He, O, Mg, Si, Ti. Cr, Fe, Ni, Pr and Nd. An abundance analysis was carried out using ZEEMAN, a program which synthesizes spectral line profiles for stars with permeating magnetic fields. The magnetic field structure was characterized by a colinear multipole expansion from the observed variations of the longitudinal and surface fields with rotational phase. Both magnetic hemispheres are clearly visible during the stellar rotation, and thus a three-ring abundance distribution model encompassing both magnetic poles and magnetic equator with equal spans in colatitude was adopted. Using the new magnetic field measurements and optical photometry together with previously published data, we refine the period of HD 133880 to P = 0.877 476 +/- 0.000009 d. Our simple axisymmetric magnetic field model is based on a predominantly quadrupolar component that roughly describes the field variations. Using spectrum synthesis, we derived mean abundances for O, Mg, Si, Ti, Cr, Fe and Pr. All elements; except Mg, are overabundant compared to the Son. Mg appears to be approximately uniform over the stellar surface, while all other elements are more abundant in the negative magnetic hemisphere than in the positive magnetic hemisphere. In contrast to most Ap/Bp stars which show an underabundance in 0, in HD 133880 this element is clearly overabundant compared to the solar abundance ratio. In studying the Ha and Paschen lines in the optical spectra, we could not unambiguously detect information about the magnetosphere of HD 133880. However, radio emission data at both 3 and 6 cm suggest that the magnetospheric plasma is held in rigid rotation with the star by the magnetic field and further supported against collapse by the rapid rotation. Subtle differences in the shapes of the optically thick radio light curves at 3 and 6 cm suggest that the large-scale magnetic field is not fully axisymmetric at large distances from the star.
Juranek, Jenifer; Filipek, Pauline A; Berenji, Gholam R; Modahl, Charlotte; Osann, Kathryn; Spence, M Anne
2006-12-01
Our objective was to evaluate brain-behavior relationships between amygdala volume and anxious/depressed scores on the Child Behavior Checklist in a well-characterized population of autistic children. Volumes for the amygdala, hippocampus, and whole brain were obtained from three-dimensional magnetic resonance images (MRIs) captured from 42 children who met the criteria for autistic disorder. Anxious/depressed symptoms were assessed in these children by the Anxious/Depressed subscale of the Child Behavior Checklist. To investigate the association between anxious/depressed scores on the Child Behavior Checklist and amygdala volume, data were analyzed using linear regression methods with Pearson correlation coefficients. A multivariate model was used to adjust for potential covariates associated with amygdala volume, including age at MRI and total brain size. We found that anxious/depressed symptoms were significantly correlated with increased total amygdala volume (r = .386, P = .012) and right amygdala volume (r = .469, P = .002). The correlation between anxious/depressed symptoms and left amygdala volume did not reach statistical significance (r = .249, P = .112). Child Behavior Checklist anxious/depressed scores were found to be a significant predictor of amygdala total (P = .014) and right amygdala (P = .002) volumes. In conclusion, we have identified a significant brain-behavior relationship between amygdala volume and anxious/depressed scores on the Child Behavior Checklist in our autistic cohort. This specific relationship has not been reported in autism. However, the existing literature on human psychiatry and behavior supports our reported evidence for a neurobiologic relationship between symptoms of anxiety and depression with amygdala structure and function. Our results highlight the importance of characterizing comorbid psychiatric symptomatology in autism. The abundance of inconsistent findings in the published literature on autism might reflect differences between study populations regarding age at MRI, level of impairment within autistic subjects, and underlying anxiety level in the selected study groups.
The ultraviolet flux distribution of Alpha-2 Canum Venaticorum
NASA Technical Reports Server (NTRS)
Leckrone, D. S.; Snijders, M. A. J.
1979-01-01
Intermediate- and narrow-band UV spectrophotometry from Copernicus, OAO 2, the S2-68 experiment on TD 1, and a sounding-rocket experiment are combined with ground-based observations to define the absolute flux distribution of the bright magnetic Ap star Alpha-2 CVn over the wavelength range from 1030 to 7580 A. Two flux distributions are presented which coincide more or less with the rare-earth maximum and minimum in the star's cycle. The results are compared with those for two normal stars, the UV variability of Alpha-2 CVn is characterized as a function of wavelength, and non-LTE effects on the UV continua of C I and Si I are analyzed. Some physical properties of Alpha-2 CVn are estimated, and the evolutionary age of the star is estimated to be between 220 million and 300 million years. It is concluded that Alpha-2 CVn is old enough to have been magnetically braked to its current rotational velocity by either the centrifugal-wind or the accretion mechanism and to have developed its chemical peculiarities by either mechanism.
NASA Astrophysics Data System (ADS)
Louro, V. H.; Ribeiro, V. B.; Mantovani, M. S.; Geolit Team
2013-05-01
The Indiavaí-Lucialva Shear Zone (ILSZ) has a notorious cinematic standard, moving from SW to NE, juxtaposing the Santa Helena Granitic Batholith to the metavolcanosedimentary sets and orthogneisses from the Jauru Domain basement. Along the ILSZ, a sequence of magnetic anomalies of high interference, with each other, and varied polarities occurs, what suggests the presence of different lithologies or times of (re)crystallization of the ferromagnetic minerals from these magnetic structures. In its southernmost portion, the sequence of magnetic anomalies splits in two directions, SW and SE, with the first invading the limits of the Santa Helena batholith and, the latest, accompanying the ILSZ. This study aimed for the comprehension of complex tectonic setting of this region. It analyzed the set of anomalies estimating their lateral limits, depths and directions of total magnetization, with the Enhanced Horizontal Derivatives (EHD), its extrapolation for depth estimative (EHD-Depth), and through an iterative reduction to the magnetic pole, respectively. This procedure allowed the composition of initial models for further inversions of magnetic data which, results, indicate contrasts of magnetic susceptibility in sub-surface. Once known the approximated 3-D shape of the magnetic structures along the ILSZ, the total magnetization intensity of each anomaly was recovered, what consequently allowed, by vector subtraction, to estimate their individual remnant magnetization. The remnant magnetization's inclinations and declinations of the anomalies sources and their latitudes and longitudes permitted the calculus of their respective virtual magnetic paleopoles. When confronted with the South American paleopole wander path and the datings linked to this path, available in the literature, it was possible to have an indirect approximation of the age of (re)crystallization of each magnetic structure near the ILSZ. This procedure indicated an increasing of the ages of the structures from SE (1298 Ma) to NW (1439 Ma). The southwestern anomalies invading the Santa Helena batholith showed ages of approximately 1419 Ma, what allows to infer their allocation with the rest of the intrusion of the batholith.; Total magnetic field map of the region of the ILSZ, locating the studied anomalies, mineral occurences and tectonic limits.
Bioluminescent magnetic nanoparticles as potential imaging agents for mammalian spermatozoa.
Vasquez, Erick S; Feugang, Jean M; Willard, Scott T; Ryan, Peter L; Walters, Keisha B
2016-03-17
Nanoparticles have emerged as key materials for developing applications in nanomedicine, nanobiotechnology, bioimaging and theranostics. Existing bioimaging technologies include bioluminescent resonance energy transfer-conjugated quantum dots (BRET-QDs). Despite the current use of BRET-QDs for bioimaging, there are strong concerns about QD nanocomposites containing cadmium which exhibits potential cellular toxicity. In this study, bioluminescent composites comprised of magnetic nanoparticles and firefly luciferase (Photinus pyralis) are examined as potential light-emitting agents for imaging, detection, and tracking mammalian spermatozoa. Characterization was carried out using infrared spectroscopy, TEM and cryo-TEM imaging, and ζ-potential measurements to demonstrate the successful preparation of these nanocomposites. Binding interactions between the synthesized nanoparticles and spermatozoon were characterized using confocal and atomic/magnetic force microscopy. Bioluminescence imaging and UV-visible-NIR microscopy results showed light emission from sperm samples incubated with the firefly luciferase-modified nanoparticles. Therefore, these newly synthesized luciferase-modified magnetic nanoparticles show promise as substitutes for QD labeling, and can potentially also be used for in vivo manipulation and tracking, as well as MRI techniques. These preliminary data indicate that luciferase-magnetic nanoparticle composites can potentially be used for spermatozoa detection and imaging. Their magnetic properties add additional functionality to allow for manipulation, sorting, or tracking of cells using magnetic techniques.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Ida, K.; Kobayashi, T.; Yoshinuma, M.
Bifurcation physics of the magnetic island was investigated using the heat pulse propagation technique produced by the modulation of electron cyclotron heating. There are two types of bifurcation phenomena observed in LHD and DIII-D. One is a bifurcation of the magnetic topology between nested and stochastic fields. The nested state is characterized by the bi-directional (inward and outward) propagation of the heat pulse with slow propagation speed. The stochastic state is characterized by the fast propagation of the heat pulse with electron temperature flattening. The other bifurcation is between magnetic island with larger thermal diffusivity and that with smaller thermalmore » diffusivity. The damping of toroidal flow is observed at the O-point of the magnetic island both in helical plasmas and in tokamak plasmas during a mode locking phase with strong flow shears at the boundary of the magnetic island. Associated with the stochastization of the magnetic field, the abrupt damping of toroidal flow is observed in LHD. The toroidal flow shear shows a linear decay, while the ion temperature gradient shows an exponential decay. Lastly, this observation suggests that this flow damping is due to the change in the non-diffusive term of momentum transport.« less
Probing Stellar Dynamics With Space Photometry
NASA Astrophysics Data System (ADS)
García, Rafael A.; Salabert, D.; Ballot, J.; Beck, P. G.; Bigot, L.; Corsaro, E.; Creevey, O.; Egeland, R.; Jiménez, A.; Mathur, S.; Metcalfe, T.; do Nascimento, J.; Pallé, P. L.; Pérez Hernández, F.; Regulo, C.
2016-08-01
The surface magnetic field has substantial influence on various stellar properties that can be probed through various techniques. With the advent of new space-borne facilities such as CoRoT and Kepler, uninterrupted long high-precision photometry is available for hundred of thousand of stars. This number will substantially grow through the forthcoming TESS and PLATO missions. The unique Kepler observations -covering up to 4 years with a 30-min cadence- allows studying stellar variability with different origins such as pulsations, convection, surface rotation, or magnetism at several time scales from hours to years. We study the photospheric magnetic activity of solar-like stars by means of the variability induced in the observed signal by starspots crossing the visible disk. We constructed a solar photometric magnetic activity proxy, Sph from SPM/VIRGO/SoHO, as if the Sun was a distant star and we compare it with several solar well-known magnetic proxies. The results validate this approach. Thus, we compute the Sph proxy for a set of CoRoT and Kepler solar-like stars for which pulsations were already detected. After characterizing the rotation and the magnetic properties of 300 solar-like stars, we use their seismic properties to characterize 18 solar analogs for which we study their magnetism. This allows us to put the Sun into context of its siblings.
Ida, K.; Kobayashi, T.; Yoshinuma, M.; ...
2016-07-29
Bifurcation physics of the magnetic island was investigated using the heat pulse propagation technique produced by the modulation of electron cyclotron heating. There are two types of bifurcation phenomena observed in LHD and DIII-D. One is a bifurcation of the magnetic topology between nested and stochastic fields. The nested state is characterized by the bi-directional (inward and outward) propagation of the heat pulse with slow propagation speed. The stochastic state is characterized by the fast propagation of the heat pulse with electron temperature flattening. The other bifurcation is between magnetic island with larger thermal diffusivity and that with smaller thermalmore » diffusivity. The damping of toroidal flow is observed at the O-point of the magnetic island both in helical plasmas and in tokamak plasmas during a mode locking phase with strong flow shears at the boundary of the magnetic island. Associated with the stochastization of the magnetic field, the abrupt damping of toroidal flow is observed in LHD. The toroidal flow shear shows a linear decay, while the ion temperature gradient shows an exponential decay. Lastly, this observation suggests that this flow damping is due to the change in the non-diffusive term of momentum transport.« less
NASA Astrophysics Data System (ADS)
Sturner, Andrew P.; Eriksson, Stefan; Nakamura, Takuma; Gershman, Daniel J.; Plaschke, Ferdinand; Ergun, Robert E.; Wilder, Frederick D.; Giles, Barbara; Pollock, Craig; Paterson, William R.; Strangeway, Robert J.; Baumjohann, Wolfgang; Burch, James L.
2018-02-01
Two magnetopause current sheet crossings with tripolar guide magnetic field signatures were observed by multiple Magnetosphere Multiscale (MMS) spacecraft during Kelvin-Helmholtz wave activity. The two out-of-plane magnetic field depressions of the tripolar guide magnetic field are largely supported by the observed in-plane electron currents, which are reminiscent of two clockwise Hall current loop systems. A comparison with a three-dimensional kinetic simulation of Kelvin-Helmholtz waves and vortex-induced reconnection suggests that MMS likely encountered the two Hall magnetic field depressions on either side of a magnetic reconnection X-line. Moreover, MMS observed an out-of-plane current reversal and a corresponding in-plane magnetic field rotation at the center of one of the current sheets, suggesting the presence of two adjacent flux ropes. The region inside one of the ion-scale flux ropes was characterized by an observed decrease of the total magnetic field, a strong axial current, and significant enhancements of electron density and parallel electron temperature. The flux rope boundary was characterized by currents opposite this axial current, strong in-plane and converging electric fields, parallel electric fields, and weak electron-frame Joule dissipation. These return current region observations may reflect a need to support the axial current rather than representing local reconnection signatures in the absence of any exhausts.
Al Mamoori, Mohanad K. I.; Keller, Lukas; Pieper, Jonathan; Winkler, Robert; Plank, Harald; Müller, Jens
2018-01-01
Three-dimensional (3D) nanomagnetism, where spin configurations extend into the vertical direction of a substrate plane allow for more complex, hierarchical systems and the design of novel magnetic effects. As an important step towards this goal, we have recently demonstrated the direct-write fabrication of freestanding ferromagnetic 3D nano-architectures of ferromagnetic CoFe in shapes of nano-tree and nano-cube structures by means of focused electron beam induced deposition. Here, we present a comprehensive characterization of the magnetic properties of these structures by local stray-field measurements using a high-resolution micro-Hall magnetometer. Measurements in a wide range of temperatures and different angles of the externally applied magnetic field with respect to the surface plane of the sensor are supported by corresponding micromagnetic simulations, which explain the overall switching behavior of in part rather complex magnetization configurations remarkably well. In particular, the simulations yield coercive and switching fields that are in good quantitative correspondence with the measured coercive and switching fields assuming a bulk metal content of 100 at % consisting of bcc Co3Fe. We show that thermally-unstable magnetization states can be repetitively prepared and their lifetime controlled at will, a prerequisite to realizing dynamic and thermally-active magnetic configurations if the building blocks are to be used in lattice structures. PMID:29439553
The Uncertainty of Local Background Magnetic Field Orientation in Anisotropic Plasma Turbulence
DOE Office of Scientific and Technical Information (OSTI.GOV)
Gerick, F.; Saur, J.; Papen, M. von, E-mail: felix.gerick@uni-koeln.de
In order to resolve and characterize anisotropy in turbulent plasma flows, a proper estimation of the background magnetic field is crucially important. Various approaches to calculating the background magnetic field, ranging from local to globally averaged fields, are commonly used in the analysis of turbulent data. We investigate how the uncertainty in the orientation of a scale-dependent background magnetic field influences the ability to resolve anisotropy. Therefore, we introduce a quantitative measure, the angle uncertainty, that characterizes the uncertainty of the orientation of the background magnetic field that turbulent structures are exposed to. The angle uncertainty can be used asmore » a condition to estimate the ability to resolve anisotropy with certain accuracy. We apply our description to resolve the spectral anisotropy in fast solar wind data. We show that, if the angle uncertainty grows too large, the power of the turbulent fluctuations is attributed to false local magnetic field angles, which may lead to an incorrect estimation of the spectral indices. In our results, an apparent robustness of the spectral anisotropy to false local magnetic field angles is observed, which can be explained by a stronger increase of power for lower frequencies when the scale of the local magnetic field is increased. The frequency-dependent angle uncertainty is a measure that can be applied to any turbulent system.« less
Probing equilibrium by nonequilibrium dynamics: Aging in Co/Cr superlattices
NASA Astrophysics Data System (ADS)
Binek, Christian
2013-03-01
Magnetic aging phenomena are investigated in a structurally ordered Co/Cr superlattice through measurements of magnetization relaxation, magnetic susceptibility, and hysteresis at various temperatures above and below the onset of collective magnetic order. We take advantage of the fact that controlled growth of magnetic multilayer thin films via molecular beam epitaxy allows tailoring the intra and inter-layer exchange interaction and thus enables tuning of magnetic properties including the spin-fluctuation spectra. Tailored nanoscale periodicity in Co/Cr multilayers creates mesoscopic spatial magnetic correlations with slow relaxation dynamics when quenching the system into a nonequilibrium state. Magnetization relaxation in weakly correlated spin systems depends on the microscopic spin-flip time of about 10 ns and is therefore a fast process. The spin correlations in our Co/Cr superlattice bring the magnetization dynamics to experimentally better accessible time scales of seconds or hours. In contrast to spin-glasses, where slow dynamics due to disorder and frustration is a well-known phenomenon, we tune and increase relaxation times in ordered structures. This is achieved by increasing spin-spin correlation between mesoscopically correlated regions rather than individual atomic spins, a concept with some similarity to block spin renormalization. Magnetization transients are measured after exposing the Co/Cr heterostructure to a magnetic set field for various waiting times. Scaling analysis reveals an asymptotic power-law behavior in accordance with a full aging scenario. The temperature dependence of the relaxation exponent shows pronounced anomalies at the equilibrium phase transitions of the antiferromagnetic superstructure and the ferromagnetic to paramagnetic transition of the Co layers. The latter leaves only weak fingerprints in the equilibrium magnetic behavior but gives rise to a prominent change in nonequilibrium properties. Our findings suggest that scaling analysis of nonequilibrium data can serve as a probe for weak equilibrium phase transitions. Financial support by NRI, and NSF through EPSCoR, and MRSEC 0820521 is greatly acknowledged.
Chemical magnetization when determining Thellier paleointensity experiments in oceanic basalts
NASA Astrophysics Data System (ADS)
Tselebrovskiy, Alexey; Maksimochkin, Valery
2017-04-01
The natural remanent magnetization (NRM) of oceanic basalts selected in the rift zones of the Mid-Atlantic Ridge (MAR) and the Red Sea has been explored. Laboratory simulation shows that the thermoremanent magnetization and chemical remanent magnetization (CRM) in oceanic basalts may be separated by using Tellier-Coe experiment. It was found that the rate of CRM destruction is about four times lower than the rate of the partial thermoremanent magnetization formation in Thellier cycles. The blocking temperatures spectrum of chemical component shifted toward higher temperatures in comparison with the spectrum of primary thermoremanent magnetization. It was revealed that the contribution of the chemical components in the NRM increases with the age of oceanic basalts determined with the analysis of the anomalous geomagnetic field (AGF) and spreading theory. CRM is less than 10% at the basalts aged 0.2 million years, less than 50% at basalts aged 0.35 million years, from 60 to 80% at basalts aged 1 million years [1]. Geomagnetic field paleointensity (Hpl) has been determined through the remanent magnetization of basalt samples of different ages related to Brunhes, Matuyama and Gauss periods of the geomagnetic field polarity. The value of the Hpl determined by basalts of the southern segment of MAR is ranged from 17.5 to 42.5 A/m, by the Reykjanes Ridge basalts — from 20.3 to 44 A/m, by the Bouvet Ridge basalts — from 21.7 to 34.1 A/m. VADM values calculated from these data are in good agreement with the international paleointensity database [2] and PISO-1500 model [3]. Literature 1. Maksimochkin V., Tselebrovskiy A., (2015) The influence of the chemical magnetization of oceanic basalts on determining the geomagnetic field paleointensity by the thellier method, moscow university physics bulletin, 70(6):566-576, 2. Perrin, M., E. Schnepp, and V. Shcherbakov (1998), Update of the paleointensity database, Eos Trans. AGU, 79, 198. 3. Channell JET, Xuan C, Hodell DA (2009) Stacking paleointensity and oxygen isotope data for the last 1.5 Myr (PISO-1500). Earth Planet Sci Lett 283:14-23.
Detailed characterization of the LLNL imaging proton spectrometer
Rasmus, A. M.; Hazi, A. U.; Manuel, M. J. -E.; ...
2016-09-01
Here, ultra-intense short pulse lasers incident on solid targets (e.g., several um thick Au foils) produce well collimated, broad-energy-spectrum proton beams. These proton beams can be used to characterize magnetic fields, electric fields (through particle deflection), and density gradients (through collisions) in high energy-density systems. The LLNL-Imaging Proton Spectrometer (L-IPS) was designed and built for use with such laser produced proton beams. The L-IPS has an energy range of 50 keV-40 MeV with a resolving power (E/dE) of about 275 at 1 MeV and 21 at 20 MeV, as well as a single spatial imaging axis. The protons enter themore » diagnostic through a vertical slit, aligned with a magnetic field imposed by permanent magnets. The protons are deflected perpendicular to the magnetic field (and therefor slit), so that spatial information in the direction of the slit is preserved. The extent to which the protons are bent by the magnetic field depends on the energy, so that the energy of the protons can be resolved as well. The protons are then measured by image plates, in which a meta-stable state is excited by collisions with the protons, which can later be imaged by a scanner. In order to better characterize the dispersion and imaging capability of this diagnostic, a 3D finite element analysis solver is used to calculate the magnetic field of the L-IPS. Particle trajectories are then obtained via numerical integration to determine the dispersion relation of the L-IPS in both energy and angular space.« less
NASA Astrophysics Data System (ADS)
Garza, Roberto S. Molina; Geissman, John; Wawrzyniec, Tim; Weber, Bodo; Martínez, Margarita López; Aranda-Gómez, Jorge
2009-06-01
The Permian age Chiapas Massif in southeast Mexico is locally host to well-exposed pseudotachylyte vein networks. The veins are black to dark grey and aphanitic in appearance, and consist mostly of microbreccia of angular fragments of plagioclase, K-feldspar, biotite and quartz, in a cryptocrystalline (microscopically irresolvable) matrix. Evidence of melting is present in the form of glass seams, dikelets, glass clasts included in cataclasite and a distinct chemistry in the pseudotachylite veins; pristine glass represents a relatively small volume of the pseudotachylite veins. At an exposure along the Tablón River valley, where the host rock is a medium to coarse-grained equigranular quartz diorite, individual veins are consistently oriented about 280°, are up to 16 mm wide, tens of cm apart, display a consistent left-lateral offset and can be traced for several metres. Individual pseudotachylyte veins rarely cross each other, and they cannot be directly linked to a regional-scale fault. Pseudotachylytes are apparently formed by a combination of crushing, comminution and frictional melting, but they are cataclasite dominated. Textures indicate that cataclasis continued after frictional melting had ceased. A 40Ar/39Ar age determination from whole rock chips of one vein shows a climbing Ar release spectrum with a date of ~114 Ma as the most reliable age estimate for Ar retention. This result is interpreted in the context of pseudotachylyte formation, recrystallization and resetting of K-bearing minerals for the K-Ar system in the late Early Cretaceous. Ten veins were sampled for palaeomagnetic and magnetic fabric studies, with samples collected from both the veins and their host rock. Remanence data give moderate natural remanent magnetization (NRM) intensities for both the veins (e.g. NRM mean 6.6 × 10-3 A m-1 σ = 5.5) and host rock (mean 7.7 × 10-3 A m-1 σ = 10.8). Many samples of host rock yield an ill-defined east-west directed and shallow magnetization, which we interpret as a Late Permian magnetization based on previous studies of the Chiapas Massif. This magnetization resides in haematite. Veins, as well as immediately adjacent host rock, typically have well-defined, single polarity magnetizations of north-northwest declination and moderate positive inclination and these resemble the Cretaceous expected field direction. The overall mean of the veins is of Dec = 348.7° and Inc = 33.6° (k = 30.5 and α95 = 12.3° n = 6 site means). Rock magnetic parameters suggest that the remanence in the veins principally resides in low-Ti pseudo-single domain magnetite and maghemite grains, but haematite, coarse-grained magnetite, rutile, Fe-Cr-Ni oxides and ilmenite are also present in the veins. Bulk magnetic susceptibility values range between ~0.3 and 1.1 * 10-3 SI volume units, and host rock values do not differ significantly from vein values. The orientations of the principal susceptibility axes in the host rock and the veins are indistinguishable. In both, magnetic foliations are near vertical and are essentially parallel to the nearly east-west orientation of the veins. Nonetheless, host rock fabrics are predominantly prolate, whereas vein fabrics are oblate. The mean susceptibility tensors of host rocks and pseudotachylyte are characterized by P'/T values of 1.041/-0.327 and 1.033/+0.302, respectively. This result suggests that the fabric reflected by magnetic susceptibility anisotropy in the veins was formed under pure shear stress, during cooling of the veins. The lack of evidence of fabric rotation supports models that associate partial melt with viscous break during fault slip.
NASA Astrophysics Data System (ADS)
Huber, C.; Abert, C.; Bruckner, F.; Groenefeld, M.; Muthsam, O.; Schuschnigg, S.; Sirak, K.; Thanhoffer, R.; Teliban, I.; Vogler, C.; Windl, R.; Suess, D.
2016-10-01
3D print is a recently developed technique, for single-unit production, and for structures that have been impossible to build previously. The current work presents a method to 3D print polymer bonded isotropic hard magnets with a low-cost, end-user 3D printer. Commercially available isotropic NdFeB powder inside a PA11 matrix is characterized, and prepared for the printing process. An example of a printed magnet with a complex shape that was designed to generate a specific stray field is presented, and compared with finite element simulation solving the macroscopic Maxwell equations. For magnetic characterization, and comparing 3D printed structures with injection molded parts, hysteresis measurements are performed. To measure the stray field outside the magnet, the printer is upgraded to a 3D magnetic flux density measurement system. To skip an elaborate adjusting of the sensor, a simulation is used to calibrate the angles, sensitivity, and the offset of the sensor. With this setup, a measurement resolution of 0.05 mm along the z-axes is achievable. The effectiveness of our calibration method is shown. With our setup, we are able to print polymer bonded magnetic systems with the freedom of having a specific complex shape with locally tailored magnetic properties. The 3D scanning setup is easy to mount, and with our calibration method we are able to get accurate measuring results of the stray field.
Low temperature magnetic behaviour near 35 K in unmetamorphosed claystones
NASA Astrophysics Data System (ADS)
Kars, Myriam; Aubourg, Charles; Pozzi, Jean-Pierre
2011-09-01
There is growing evidence that the magnetic assemblage of claystones, illustrated by low-temperature magnetic transitions at ˜120 K and ˜35 K, may be representative of the peak burial temperature in the so-called oil-window (60-150°C). In previous studies, it was proposed that this magnetic assemblage is characterized by fine-grained pyrrhotite (Fe7S8) and magnetite (Fe3O4). However, evidence of pyrrhotite was not so obvious and the magnetic transition near 35 K of fine-grained pyrrhotite has similarities with those of siderite (FeCO3) or rhodochrosite (MnCO3). Here, we propose some diagnostic tests to distinct <50 K behaviours by studying claystones from Netherlands borehole and Borneo Prism that experienced different peak burial temperatures. We perform magnetic susceptibility, temperature dependency of SIRM (ZFC, RT-SIRM) and field cooled hysteresis loops. On cooling of RT-SIRM (300 K to 10 K), we applied a magnetic field of 5 μT to enhance Néel type magnetic transition. It is found that our samples can be classified in two categories based on the shape of the RT-SIRM curve: one displaying an abrupt break-in-slope in the remanence at ˜30 K, called N-behaviour, and the other one characterized by a progressive increase of the remanent magnetization by 80 K, named P-behaviour. The first category contains essentially magnetite and Fe-Mn carbonates, the second one magnetite and probably iron sulphides.
Tan, Zhengying; Lu, Senlin; Zhao, Hui; Kai, Xiao; Jiaxian, Peng; Win, Myat Sandar; Yu, Shang; Yonemochi, Shinich; Wang, Qingyue
2018-01-19
As an accumulation of solid organic and inorganic pollutant particles on outdoor ground surfaces, road dust is an important carrier of heavy metal contaminants and can be a valuable medium for characterizing urban environmental quality. Because the dusts can be an important source of atmospheric particles and take impact on human health, the aim of this study described in detail the mineralogical characteristics, morphology, and heavy metal content of road dust from Xuanwei and Fuyuan, locations with high lung cancer incidence. Our results show that the average concentrations of heavy metals in road dust were higher than their background values. Higher concentrations of heavy metals were found in the magnetic fractions (MFs) than in the non-magnetic fractions (NMFs). Magnetic measurements revealed high magnetic susceptibility values in the road dust samples, and the dominant magnetic carrier was magnetite. The magnetic grains were predominantly pseudo-single domain, multi-domain, and coarse-grained stable single domains (coarse SSD) in size. SEM/XRD analysis identified two groups of magnetic particles: spherules and angular/aggregate particles. Hazard index (HI) values for adults exposure to road dust samples, including MF, Bulk, and NMF, in both areas were lower or close to safe levels, while HI values for childhood exposure to magnetic fractions in both areas were very close or higher than safe levels. Cancer risks from road dust exposure in both areas were in the acceptable value range.
Laminated grid and web magnetic cores
Sefko, John; Pavlik, Norman M.
1984-01-01
A laminated magnetic core characterized by an electromagnetic core having core legs which comprise elongated apertures and edge notches disposed transversely to the longitudinal axis of the legs, such as high reluctance cores with linear magnetization characteristics for high voltage shunt reactors. In one embodiment the apertures include compact bodies of microlaminations for more flexibility and control in adjusting permeability and/or core reluctance.
Structural and magnetic properties of Ni-Zn doped BaM nanocomposite via citrate precursor
DOE Office of Scientific and Technical Information (OSTI.GOV)
Rana, Kush; Thakur, Preeti; Thakur, Atul, E-mail: atulphysics@gmail.com
2016-05-23
Ni-Zn substituted M-type barium ferrite nanocomposite has been prepared via citrate precursor method. Nanocomposite having composition BaNi{sub 0.5}Zn{sub 0.5}Fe{sub 11}O{sub 19} was sintered at 900°C for 3hrs and characterized by using different characterization techniques. X-ray diffraction (XRD) confirmed the formation of double phase with most prominent peak at (114). Average crystallite size for pure BaM and BNZFO were found to be 36 nm & 45 nm. Field emission scanning electron microscopy (FESEM) confirmed the formation of hexagonal platelets with a layered structure. Magnetic properties of these samples were investigated by using vibrating sample magnetometer (VSM). Magnetic parameters like saturation magnetization (M{sub s}),more » coericivity (H{sub c}) and squareness ratio (SQR) of nanocomposite were found to be 60 emu/g, 3663 Oe and 0.6163 respectively. These values were noticed to be higher as compared to pure BaM. Enhanced magnetic properties of nanocomposite were strongly dependent on exchange coupling. Therefore these properties make this nanocomposite a suitable candidate for magnetic recording and high frequency applications.« less
Synthesis, characterization and in vivo evaluation of biocompatible ferrogels
NASA Astrophysics Data System (ADS)
Lopez-Lopez, M. T.; Rodriguez, I. A.; Rodriguez-Arco, L.; Carriel, V.; Bonhome-Espinosa, A. B.; Campos, F.; Zubarev, A.; Duran, J. D. G.
2017-06-01
A hydrogel is a 3-D network of polymer chains in which water is the dispersion medium. Hydrogels have found extensive applications in the biomedical field due to their resemblance to living tissues. Furthermore, hydrogels can be endowed with exceptional properties by addition of synthetic materials. For example, magnetic field-sensitive gels, called ferrogels, are obtained by embedding magnetic particles in the polymer network. Novel living tissues with unique magnetic field-sensitive properties were recently prepared by 3-D cell culture in biocompatible ferrogels. This paper critically reviews the most recent progress and perspectives in their synthesis, characterization and biocompatibility evaluation. Optimization of ferrogels for this novel application requires low-density, strongly magnetic, multi-domain particles. Interestingly, the rheological properties of the resulting ferrogels in the absence of field were largely enhanced with respect to nonmagnetic hydrogels, which can only be explained by the additional cross-linking imparted by the embedded magnetic particles. Remarkably, rheological measurements under an applied magnetic field demonstrated that ferrogels presented reversibly tunable mechanical properties, which constitutes a unique advantage with respect to nonmagnetic hydrogels. In vivo evaluation of ferrogels showed good biocompatibility, with only some local inflammatory response, and no particle migration or damage to distant organs.
Magnetization Dynamics of Amorphous Ribbons and Wires Studied by Inductance Spectroscopy
Betancourt, Israel
2010-01-01
Inductance spectroscopy is a particular formulation variant of the well known complex impedance formalism typically used for the electric characterization of dielectric, ferroelectric, and piezoelectric materials. It has been successfully exploited as a versatile tool for characterization of the magnetization dynamics in amorphous ribbons and wires by means of simple experiments involving coils for sample holding and impedance analyzer equipment. This technique affords the resolution of the magnetization processes in soft magnetic materials, in terms of reversible deformation of pinned domain walls, domain wall displacements and spin rotation, for which characteristic parameters such as the alloy initial permeability and the relaxation frequencies, indicating the dispersion of each process, can be defined. Additionally, these parameters can be correlated with chemical composition variation, size effects and induced anisotropies, leading to a more physical insight for the understanding of the frequency dependent magnetic response of amorphous alloys, which is of prime interest for the development of novel applications in the field of telecommunication and sensing technologies. In this work, a brief overview, together with recent progress on the magnetization dynamics of amorphous ribbons, wires, microwires and biphase wires, is presented and discussed for the intermediate frequency interval between 10 Hz and 13 MHz. PMID:28879975
DOE Office of Scientific and Technical Information (OSTI.GOV)
Correa, E. L., E-mail: eduardo.correa@usp.br; Bosch-Santos, B.; Cavalcante, F. H. M.
2016-05-15
The magnetic behavior of Gd{sub 2}O{sub 3} nanoparticles, produced by thermal decomposition method and subsequently annealed at different temperatures, was investigated by magnetization measurements and, at an atomic level, by perturbed γ − γ angular correlation (PAC) spectroscopy measuring hyperfine interactions at {sup 111}In({sup 111}Cd) probe nuclei. Nanoparticle structure, size and shape were characterized by X-ray diffraction (XRD) and Transmission Electron Microscopy (TEM). Magnetization measurements were carried out to characterize the paramagnetic behavior of the samples. XRD results show that all samples crystallize in the cubic-C form of the bixbyite structure with space group Ia3. TEM images showed that particlesmore » annealed at 873 K present particles with highly homogeneous sizes in the range from 5 nm to 10 nm and those annealed at 1273 K show particles with quite different sizes from 5 nm to 100 nm, with a wide size distribution. PAC and magnetization results show that samples annealed at 873 and 1273 K are paramagnetic. Magnetization measurements show no indication of blocking temperatures for all samples down to 2 K and the presence of antiferromagnetic correlations.« less
A new polyester based on allyl α-hydroxy glutarate as shell for magnetite nanoparticles
NASA Astrophysics Data System (ADS)
Nan, Alexandrina; Feher, Ioana Coralia
2017-12-01
Allyl side-chain-functionalized lactide was synthesized from commercially available glutamic acid and polymerized by ring opening polymerization using 4-dimethylaminopyridine as an organocatalyst in the presence of magnetic nanoparticles. The resulting magnetic nanostructures coated with the allyl-containing polyester were then functionalized with cysteine by thiol-ene click reaction leading to highly functionalized magnetic nano-platforms of practical interest. The polyester precursors were characterized by nuclear magnetic resonance and mass spectrometry. The morphology of magnetic nanostructures based on the functionalized polyester was determined by transmission electron microscopy TEM, while the chemical structure was investigated by FT-IR. TGA investigations and the magnetic properties of the magnetic nanostructures are also described.
MTL distributed magnet measurement system
DOE Office of Scientific and Technical Information (OSTI.GOV)
Nogiec, J.M.; Craker, P.A.; Garbarini, J.P.
1993-04-01
The Magnet Test Laboratory (MTL) at the Superconducting Super collider Laboratory will be required to precisely and reliably measure properties of magnets in a production environment. The extensive testing of the superconducting magnets comprises several types of measurements whose main purpose is to evaluate some basic parameters characterizing magnetic, mechanic and cryogenic properties of magnets. The measurement process will produce a significant amount of data which will be subjected to complex analysis. Such massive measurements require a careful design of both the hardware and software of computer systems, having in mind a reliable, maximally automated system. In order to fulfillmore » this requirement a dedicated Distributed Magnet Measurement System (DMMS) is being developed.« less
NASA Technical Reports Server (NTRS)
Connerney, J. E. P.
2007-01-01
The chapter on Planetary Magnetism by Connerney describes the magnetic fields of the planets, from Mercury to Neptune, including the large satellites (Moon, Ganymede) that have or once had active dynamos. The chapter describes the spacecraft missions and observations that, along with select remote observations, form the basis of our knowledge of planetary magnetic fields. Connerney describes the methods of analysis used to characterize planetary magnetic fields, and the models used to represent the main field (due to dynamo action in the planet's interior) and/or remnant magnetic fields locked in the planet's crust, where appropriate. These observations provide valuable insights into dynamo generation of magnetic fields, the structure and composition of planetary interiors, and the evolution of planets.
The Role of Brain MRI in Mitochondrial Neurogastrointestinal Encephalomyopathy
Scarpelli, Mauro; Ricciardi, Giuseppe Kenneth; Beltramello, Alberto; Zocca, Isabella; Calabria, Francesca; Russignan, Anna; Zappini, Francesca; Cotelli, Maria Sofia; Padovani, Alessandro; Tomelleri, Giuliano; Filosto, Massimiliano; Tonin, Paola
2013-01-01
Summary Leukoencephalopathy is a hallmark of mitochondrial neurogastrointestinal encephalomyopathy (MNGIE) a devastating disorder characterized by ptosis, ophthalmoparesis, gastrointestinal dysfunction and polyneuropathy. To characterize MNGIE-associated leukoencephalopathy and to correlate it with clinical, biochemical and molecular data, four MNGIE patients with heterogeneous clinical phenotypes (enteropathic arthritis, exercise intolerance, CIDP-like phenotype and typical presentation) were studied by magnetic resonance imaging (MRI) and magnetic resonance spectroscopy (MRS). Diffusion weighted imaging (DWI) with apparent diffusion coefficient (ADC) maps were also obtained. In two patients we also investigated the role of brain MRI in monitoring the evolution of leukoencephalopathy by performing follow-up imaging studies at an interval of one and two years. The extension and distribution of leukoencephalopathy were not clearly linked with age, phenotype or disease severity, and did not seem to be related to TYMP mutations, enzyme activity or pyrimidine levels. In the studied patients MRS revealed reduced N-acetyl-aspartate and increased choline signals. Although DWI appeared normal in all patients but one, ADC maps always showed moderate increased diffusivity. Leukoencephalopathy worsened over a two-year period in two patients, regardless of the clinical course, indicating a lack of correlation between clinical phenotype, size and progression of white matter abnormalities during this period. Brain MRI should be considered a very useful tool to diagnose both classical and atypical MNGIE. Serial MRIs in untreated and treated MNGIE patients will help to establish whether the leukoencephalopathy is a reversible condition or not. PMID:24199812
Magnetic resonance imaging of facial nerve schwannoma.
Thompson, Andrew L; Aviv, Richard I; Chen, Joseph M; Nedzelski, Julian M; Yuen, Heng-Wai; Fox, Allan J; Bharatha, Aditya; Bartlett, Eric S; Symons, Sean P
2009-12-01
This study characterizes the magnetic resonance (MR) appearances of facial nerve schwannoma (FNS). We hypothesize that the extent of FNS demonstrated on MR will be greater compared to prior computed tomography studies, that geniculate involvement will be most common, and that cerebellar pontine angle (CPA) and internal auditory canal (IAC) involvement will more frequently result in sensorineural hearing loss (SNHL). Retrospective study. Clinical, pathologic, and enhanced MR imaging records of 30 patients with FNS were analyzed. Morphologic characteristics and extent of segmental facial nerve involvement were documented. Median age at initial imaging was 51 years (range, 28-76 years). Pathologic confirmation was obtained in 14 patients (47%), and the diagnosis reached in the remainder by identification of a mass, thickening, and enhancement along the course of the facial nerve. All 30 lesions involved two or more contiguous segments of the facial nerve, with 28 (93%) involving three or more segments. The median segments involved per lesion was 4, mean of 3.83. Geniculate involvement was most common, in 29 patients (97%). CPA (P = .001) and IAC (P = .02) involvement was significantly related to SNHL. Seventeen patients (57%) presented with facial nerve dysfunction, manifesting in 12 patients as facial nerve weakness or paralysis, and/or in eight with involuntary movements of the facial musculature. This study highlights the morphologic heterogeneity and typical multisegment involvement of FNS. Enhanced MR is the imaging modality of choice for FNS. The neuroradiologist must accurately diagnose and characterize this lesion, and thus facilitate optimal preoperative planning and counseling.
Gabard-Durnam, Laurel J.; Flannery, Jessica; Goff, Bonnie; Gee, Dylan G.; Humphreys, Kathryn L.; Telzer, Eva; Hare, Todd; Tottenham, Nim
2014-01-01
Functional connections (FC) between the amygdala and cortical and subcortical regions underlie a range of affective and cognitive processes. Despite the central role amygdala networks have in these functions, the normative developmental emergence of FC between the amygdala and the rest of the brain is still largely undefined. This study employed amygdala subregion maps and resting-state functional magnetic resonance imaging to characterize the typical development of human amygdala FC from age 4 to 23 years old (n = 58). Amygdala FC with subcortical and limbic regions was largely stable across this developmental period. However, three cortical regions exhibited age-dependent changes in FC: amygdala FC with the medial prefrontal cortex (mPFC) increased with age, while amygdala FC with a region including the insula and superior temporal sulcus decreased with age, and amygdala FC with a region encompassing the parahippocampal gyrus and posterior cingulate also decreased with age. The transition from childhood to adolescence (around age 10 years) marked an important change-point in the nature of amygdala-cortical FC. We distinguished unique developmental patterns of coupling for three amygdala subregions and found particularly robust convergence of FC for all subregions with the mPFC. These findings suggest that there are extensive changes in amygdala-cortical functional connectivity that emerge between childhood and adolescence. PMID:24662579
NASA Astrophysics Data System (ADS)
Gopman, D. B.; Dennis, C. L.; McMichael, R. D.; Hao, X.; Wang, Z.; Wang, X.; Gan, H.; Zhou, Y.; Zhang, J.; Huai, Y.
2017-05-01
We report the frequency dependence of the ferromagnetic resonance linewidth of the free layer in magnetic tunnel junctions with all perpendicular-to-the-plane magnetized layers. While the magnetic-field-swept linewidth nominally shows a linear growth with frequency in agreement with Gilbert damping, an additional frequency-dependent linewidth broadening occurs that shows a strong asymmetry between the absorption spectra for increasing and decreasing external magnetic field. Inhomogeneous magnetic fields produced during reversal of the reference and pinned layer complex is demonstrated to be at the origin of the symmetry breaking and the linewidth enhancement. Consequentially, this linewidth enhancement provides indirect information on the magnetic coercivity of the reference and pinned layers. These results have important implications for the characterization of perpendicular magnetized magnetic random access memory bit cells.
Tetherless mobile micrograsping using a magnetic elastic composite material
NASA Astrophysics Data System (ADS)
Zhang, Jiachen; Diller, Eric
2016-11-01
In this letter, we propose and characterize a new type of tetherless mobile microgripper for micrograsping that is made of a magnetic elastic composite material. Its magnetically-programmable material and structures make it the first three-dimensional (3D) mobile microgripper that is directly actuated and controlled by magnetic forces and torques. With a symmetric four-limb structure, the microgripper is 3.5 mm long from tip to tip when it is open and 30 μm thick. It forms an approximate 700 μm cube when it is closed. The orientation and 3D shape of the microgripper are determined by the direction and strength of the applied magnetic field, respectively. As a mobile device, the microgripper can be moved through aqueous environments for precise grasping and transportation of micro-objects, pulled by magnetic gradients directly or rolled in rotating magnetic fields. The deformation of the microgripper under magnetic actuation is characterized by modeling and confirmed experimentally. Being directly controlled by magnetic forces and torques, the microgripper is easier and more intuitive to control than other magnetic microgrippers that require other inputs such as thermal and chemical responses. In addition, the microgripper is capable of performing fast repeatable grasping motions, requiring no more than 25 ms to change from fully open to fully closed in water at room temperature. As a result of its large-amplitude 3D deformation, the microgripper can accommodate cargoes with a wide range of geometries and dimensions. A pick-and-place experiment demonstrates the efficacy of the microgripper and its potentials in biomedical, microfluidic, and microrobotic applications.
1978-03-01
NSWC/WOL TR 77-178 SUMMARY This raport gives measurements of changes in the magnetic properties of thin films due to oxidation. Evaporated NiFe ...Fi lm An i sotropy NiFe Thi n Fi lm Th in Fi lm Magnetos triction Magnetic Fi lm Aging - Magnetic Film Anneal ing — ~~~~. A BSTRACT CenhSnu. on r.v...rs• .Id. I nsc•ss y ond Idsnhl~ b block me.eb.r) _ . .—~~ Low magnetostriction NiFe and NiFe based’ ternary films 220A to 340A thick were prepared by
NASA GRC Technology Development Project for a Stirling Radioisotope Power System
NASA Technical Reports Server (NTRS)
Thieme, Lanny G.; Schreiber, Jeffrey G.
2000-01-01
NASA Glenn Research Center (GRC), the Department of Energy (DOE), and Stirling Technology Company (STC) are developing a Stirling convertor for an advanced radioisotope power system to provide spacecraft on-board electric power for NASA deep space missions. NASA GRC is conducting an in-house project to provide convertor, component, and materials testing and evaluation in support of the overall power system development. A first characterization of the DOE/STC 55-We Stirling Technology Demonstration Convertor (TDC) under the expected launch random vibration environment was recently completed in the NASA GRC Structural Dynamics Laboratory. Two TDCs also completed an initial electromagnetic interference (EMI) characterization at NASA GRC while being tested in a synchronized, opposed configuration. Materials testing is underway to support a life assessment of the heater head, and magnet characterization and aging tests have been initiated. Test facilities are now being established for an independent convertor performance verification and technology development. A preliminary Failure Mode Effect Analysis (FMEA), initial finite element analysis (FEA) for the linear alternator, ionizing radiation survivability assessment, and radiator parametric study have also been completed. This paper will discuss the status, plans, and results to date for these efforts.
NASA Astrophysics Data System (ADS)
Fucugauchi, J. U.; Perez-Cruz, L. L.; Velasco-Villarreal, M.
2013-12-01
Drilling projects of impact structures provide data on the structure and stratigraphy of target, impact and post-impact lithologies, providing insight on the impact dynamics and cratering. Studies have successfully included magnetic well logging and analyses in core and cuttings, directed to characterize the subsurface stratigraphy and structure at depth. There are 170-180 impact craters documented in the terrestrial record, which is a small proportion compared to expectations derived from what is observed on the Moon, Mars and other bodies of the solar system. Knowledge of the internal 3-D deep structure of craters, critical for understanding impacts and crater formation, can best be studied by geophysics and drilling. On Earth, few craters have yet been investigated by drilling. Craters have been drilled as part of industry surveys and/or academic projects, including notably Chicxulub, Sudbury, Ries, Vredefort, Manson and many other craters. As part of the Continental ICDP program, drilling projects have been conducted on the Chicxulub, Bosumtwi, Chesapeake, Ries and El gygytgyn craters. Inclusion of continuous core recovery expanded the range of paleomagnetic and rock magnetic applications, with direct core laboratory measurements, which are part of the tools available in the ocean and continental drilling programs. Drilling studies are here briefly reviewed, with emphasis on the Chicxulub crater formed by an asteroid impact 66 Ma ago at the Cretaceous/Paleogene boundary. Chicxulub crater has no surface expression, covered by a kilometer of Cenozoic sediments, thus making drilling an essential tool. As part of our studies we have drilled eleven wells with continuous core recovery. Magnetic susceptibility logging, magnetostratigraphic, rock magnetic and fabric studies have been carried out and results used for lateral correlation, dating, formation evaluation, azimuthal core orientation and physical property contrasts. Contributions of magnetic studies on impact age, cratering, target-impactite stratigraphy, ejecta, impact dynamics, hydrothermal alterations and post-impact processes are presented. The challenges and perspectives of drilling studies of impact craters are discussed.
Magnetic nanotubes for drug delivery
NASA Astrophysics Data System (ADS)
Ramasamy, Mouli; Kumar, Prashanth S.; Varadan, Vijay K.
2017-04-01
Magnetic nanotubes hold the potential for neuroscience applications because of their capability to deliver chemicals or biomolecules and the feasibility of controlling the orientation or movement of these magnetic nanotubes by an external magnetic field thus facilitating directed growth of neurites. Therefore, we sought to investigate the effects of laminin treated magnetic nanotubes and external alternating magnetic fields on the growth of dorsal root ganglion (DRG) neurons in cell culture. Magnetic nanotubes were synthesized by a hydrothermal method and characterized to confirm their hollow structure, the hematite and maghemite phases, and the magnetic properties. DRG neurons were cultured in the presence of magnetic nanotubes under alternating magnetic fields. Electron microscopy showed a close interaction between magnetic nanotubes and the growing neurites Phase contrast microscopy revealed live growing neurons suggesting that the combination of the presence of magnetic nanotubes and the alternating magnetic field were tolerated by DRG neurons. The synergistic effect, from both laminin treated magnetic nanotubes and the applied magnetic fields on survival, growth and electrical activity of the DRG neurons are currently being investigated.
Magnetoacoustic Sensing of Magnetic Nanoparticles.
Kellnberger, Stephan; Rosenthal, Amir; Myklatun, Ahne; Westmeyer, Gil G; Sergiadis, George; Ntziachristos, Vasilis
2016-03-11
The interaction of magnetic nanoparticles and electromagnetic fields can be determined through electrical signal induction in coils due to magnetization. However, the direct measurement of instant electromagnetic energy absorption by magnetic nanoparticles, as it relates to particle characterization or magnetic hyperthermia studies, has not been possible so far. We introduce the theory of magnetoacoustics, predicting the existence of second harmonic pressure waves from magnetic nanoparticles due to energy absorption from continuously modulated alternating magnetic fields. We then describe the first magnetoacoustic system reported, based on a fiber-interferometer pressure detector, necessary for avoiding electric interference. The magnetoacoustic system confirmed the existence of previously unobserved second harmonic magnetoacoustic responses from solids, magnetic nanoparticles, and nanoparticle-loaded cells, exposed to continuous wave magnetic fields at different frequencies. We discuss how magnetoacoustic signals can be employed as a nanoparticle or magnetic field sensor for biomedical and environmental applications.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Halasyamani, Shiv; Fennie, Craig
2016-11-03
We have focused on the synthesis, characterization, and ab initio theory on multi-functional mixed-metal fluorides. With funding from the DOE, we have successfully synthesized and characterized a variety of mixed metal fluoride materials.
Global helioseismology (WP4.1): From the Sun to the stars & solar analogs
NASA Astrophysics Data System (ADS)
García, Rafael A.
2017-10-01
Sun-as-a star observations put our star as a reference for stellar observations. Here, I review the activities in which the SPACEINN global seismology team (Working Package WP4.1) has worked during the past 3 years. In particular, we will explain the new deliverables available on the SPACEINN seismic+ portal. Moreover, special attention will be given to surface dynamics (rotation and magnetic fields). After characterizing the rotation and the magnetic properties of around 300 solar-like stars and defining proper metrics for that, we use their seismic properties to characterize 18 solar analogues for which we study their surface magnetic and seismic properties. This allows us to put the Sun into context compared to its siblings.
Temperature compensated and self-calibrated current sensor
Yakymyshyn, Christopher Paul; Brubaker, Michael Allen; Yakymyshyn, Pamela Jane
2007-09-25
A method is described to provide temperature compensation and reduction of drift due to aging for a current sensor based on a plurality of magnetic field sensors positioned around a current carrying conductor. The offset voltage signal generated by each magnetic field sensor is used to correct variations in the output signal due to temperature variations and aging.
Motaali, Soheila; Pashaeiasl, Maryam; Akbarzadeh, Abolfazl; Davaran, Soodabeh
2017-05-01
In the present study, magnetic and thermo/pH-sensitive (multiresponsive) nanocomposites based on N-isopropylacrylamide (NIPAAM) were synthesized and characterized. Nanocomposites were synthesized by free radical emulsion polymerization of NIPAAM as thermosensitive monomer and N,N-dimethyl-aminoethyl methacrylate (DMAEMA) as pH-sensitive monomer in the presence of methylene-bis-acrylamide as cross-linking agent. Doxorubicin, an anti-cancer drug, was loaded into these nanocomposites via equilibrium swelling method. Thermo/pH-sensitive cross-linked poly (NIPAAM-DMAEMA)-Fe 3 O 4 nanocomposites were characterized by Fourier transform infrared spectroscopy (FT-IR), scanning electron microscopy (SEM), and vibrating sample magnetometer (VSM). The volume of the loaded drug and drug release amount was determined by UV measurements. The results showed that this thermo/pH-sensitive magnetic nanocomposite has a high drug-loading efficiency. Doxorubicin was released at 40 °C and pH 5.8 more than the 37 °C and pH 7.4.
Coherent 40-Hz Oscillation Characterizes Dream State in Humans
NASA Astrophysics Data System (ADS)
Llinas, Rodolfo; Ribary, Urs
1993-03-01
Magnetic recording from five normal human adults demonstrates large 40-Hz coherent magnetic activity in the awake and in rapid-eye-movement (REM) sleep states that is very reduced during delta sleep (deep sleep characterized by delta waves in the electroencephalogram). This 40-Hz magnetic oscillation has been shown to be reset by sensory stimuli in the awake state. Such resetting is not observed during REM or delta sleep. The 40 Hz in REM sleep is characterized, as is that in the awake state, by a fronto-occiptal phase shift over the head. This phase shift has a maximum duration of thickapprox12-13 msec. Because 40-Hz oscillation is seen in wakefulness and in dreaming, we propose it to be a correlate of cognition, probably resultant from coherent 40-Hz resonance between thalamocortical-specific and nonspecific loops. Moreover, we proposed that the specific loops give the content of cognition, and a nonspecific loop gives the temporal binding required for the unity of cognitive experience.
2012-12-13
pressure of ∼2.5 GPa. The final bulk magnets having dimensions Ø6 mm × 1.5 mm were characterized for morphology and the crystalline structure using scanning... Magnetic properties were measured with a superconducting quantum interference device (SQUID) magnetometer with a maximum applied field of 70 kOe. To...calculate the true energy product (BH)max of the bulk sample, we determined the demagnetization factor experimentally as described in [9]. Figure 1 shows
NASA Astrophysics Data System (ADS)
Do, Kevin; Masood, Samina
The effects of magnetic fields were investigated on two species of bacteria: Staphylococcus Aureus and Staphylococcus Epidermidis. Both cultures were grown independently in agar plates and nutrient broth with exposure to various conditions of static and oscillating magnetic fields. The effects were characterized by growth rate measurements via changes in optical density (OD) over incubation periods of 24-28 hours. Significant effects on the growth rates of both species were observed in the case of the time-varying magnetic field.
Enhanced third-harmonic generation in silicon nanoparticles driven by magnetic response.
Shcherbakov, Maxim R; Neshev, Dragomir N; Hopkins, Ben; Shorokhov, Alexander S; Staude, Isabelle; Melik-Gaykazyan, Elizaveta V; Decker, Manuel; Ezhov, Alexander A; Miroshnichenko, Andrey E; Brener, Igal; Fedyanin, Andrey A; Kivshar, Yuri S
2014-11-12
We observe enhanced third-harmonic generation from silicon nanodisks exhibiting both electric and magnetic dipolar resonances. Experimental characterization of the nonlinear optical response through third-harmonic microscopy and spectroscopy reveals that the third-harmonic generation is significantly enhanced in the vicinity of the magnetic dipole resonances. The field localization at the magnetic resonance results in two orders of magnitude enhancement of the harmonic intensity with respect to unstructured bulk silicon with the conversion efficiency limited only by the two-photon absorption in the substrate.
NASA Astrophysics Data System (ADS)
Fei, Xuening; Zhu, Huifang; Zhou, Jianguo; Yu, Lu
2014-03-01
A dual functional nanoparticle was designed and synthesized by encapsulating magnetic core inside silica particles and subsequently a thiazole orange (TO) dye derivative was modified on the surface of the nanoparticles. The obtained particles were characterized by Fourier transform infrared spectroscope, Uv-Vis spectrophotometer, fluorescence spectrophotometer, transmission electron microscope, dynamic light scattering, etc. The size of preliminary magnetic particles is ca. 7 nm, but after coating a silica layer and dye, the size of particles is increased to ca. 60 nm. The hydrodynamic diameter, water dispersibility, and zeta potential were also determined. The hydrodynamic diameter of particles with silica and dye is 65.2 and 70.5 nm, respectively, with positive zeta potential (25.1, 38.5 mV). Furthermore magnetic properties of the particles were measured and the experimental results suggested that it could meet the requirement of application as magnetic resonance imaging agent. Finally to verify the availability of the particles as fluorescent labeling, protein labeling experiment was performed using bovine serum albumin (BSA) protein and the results showed that the dual functional particle has higher affinity with BSA than TO molecule itself.
Rodriguez, A F R; Rocha, C O; Piazza, R D; Dos Santos, C C; Morales, M A; Faria, F S E D V; Iqbal, M Zubair; Barbosa, L; Chaves, Y O; Mariuba, L A; Jafelicci, M; Marques, R F C
2018-06-12
Magnetic nanoparticles (NPs) have attracted great attention owing to their applications in the biomedical field. In the present work, maghemite (γFe 2 O 3 ) NPs of 6.5 nm were prepared using a sonochemical method and used to prepare magnetic beads through silanization with 3-aminopropyltrimethoxysilane (APTS). Subsequently, amino groups in the resulting APTS-γFe 2 O 3 beads were converted to carboxylic acid (CARB-γFe 2 O 3 ) through the succinic anhydride reaction, as confirmed by transmission electron microscopy (TEM), Fourier transform infrared spectroscopy and dynamic light scattering (DLS) measurements. The size of these beads was measured as 12 nm and their hydrodynamic diameter as 490 nm, using TEM analysis and DLS, respectively. The CARB-γFe 2 O 3 beads were further functionalized by immobilizing rabbit antibodies on their surfaces; the immobilization was confirmed by flow cytometry and ionic strength. The samples were further characterized by Mössbauer spectroscopy and DC magnetization measurements. Studies on magnetic relaxivities showed that magnetic beads present great potential for application in MR imaging.
Precision Electron Density Measurements in the SSX MHD Wind Tunnel
NASA Astrophysics Data System (ADS)
Suen-Lewis, Emma M.; Barbano, Luke J.; Shrock, Jaron E.; Kaur, Manjit; Schaffner, David A.; Brown, Michael R.
2017-10-01
We characterize fluctuations of the line averaged electron density of Taylor states produced by the magnetized coaxial plasma gun of the SSX device using a 632.8 nm HeNe laser interferometer. The analysis method uses the electron density dependence of the refractive index of the plasma to determine the electron density of the Taylor states. Typical magnetic field and density values in the SSX device approach about B ≅ 0.3 T and n = 0 . 4 ×1016 cm-3 . Analysis is improved from previous density measurement methods by developing a post-processing method to remove relative phase error between interferometer outputs and to account for approximately linear phase drift due to low-frequency mechanical vibrations of the interferometer. Precision density measurements coupled with local measurements of the magnetic field will allow us to characterize the wave composition of SSX plasma via density vs. magnetic field correlation analysis, and compare the wave composition of SSX plasma with that of the solar wind. Preliminary results indicate that density and magnetic field appear negatively correlated. Work supported by DOE ARPA-E ALPHA program.
Reduced to pole long-wavelength magnetic anomalies of Africa and Europe
NASA Technical Reports Server (NTRS)
Olivier, R.; Hinze, W. J.; Vonfrese, R. R. B.
1985-01-01
To facilitate analysis of the tectonic framework for Africa, Europe and adjacent marine areas, MAGSAT scalar anomaly data are differentially reduced to the pole and compared to regional geologic information and geophysical data including surface free-air gravity anomaly data upward continued to satellite elevation (350 km) on a spherical Earth. Comparative analysis shows magnetic anomalies correspond with both ancient as well as more recent Cenozoic structural features. Anomalies associated with ancient structures are primarily caused by intra-crustal lithologic variations such as the crustal disturbance associated with the Bangui anomaly in west-central Africa. Anomalies correlative with Cenozoic tectonic elements appear to be related to Curie isotherm perturbations. A possible example of the latter is the well-defined trend of magnetic minima that characterize the Alphine orogenic belt from the Atlas mountains to Eurasia. In contrast, a well-defined magnetic satellite minimum extends across the stable craton from Finland to the Ural mountains. Prominent magnetic maxima characterize the Arabian plate, Iceland, the Kursk region of the central Russian uplift, and generally the Precambrian shields of Africa.
Reduced to Pole Long-wavelength Magnetic Anomalies of Africa and Europe
NASA Technical Reports Server (NTRS)
Hinze, W. J.; Vonfrese, R. R. B. (Principal Investigator); Olivier, R.
1984-01-01
To facilitate analysis of the tectonic framework for Africa, Europe and adjacent marine areas, MAGSAT scalar anomaly data are differentially reduced to the pole and compared to regional geologic information and geophysical data including surface free-air gravity anomaly data upward continued to satellite elevation (350 km) on a spherical Earth. Comparative analysis shows magnetic anomalies correspond with both ancient as well as more recent Cenozoic structural features. Anomalies associated with ancient structures are primarily caused by intra-crustal lithologic variations such as the crustal disturbance associated with the Bangui anomaly in west-central Africa. Anomalies correlative with Cenozoic tectonic elements appear to be related to Curie isotherm perturbations. A possible example of the latter is the well-defined trend of magnetic minima that characterize the Alpine orogenic belt from the Atlas mountains to Eurasia. In contrast, a well-defined magnetic satellite minimum extends across the stable craton from Finland to the Ural mountains. Prominent magnetic maxima characterize the Arabian plate, Iceland, the Kursk region of the central Russian uplift, and generally the Precambrian shields of Africa.
Kustas, Andrew B.; Michael, Joseph R.; Susan, Don F.; ...
2018-06-04
In Part I, equal channel angular extrusion (ECAE) was demonstrated as a novel, simple-shear deformation process for producing bulk forms of the low ductility Fe–Co–2V (Hiperco 50A®) soft ferromagnetic alloy with refined grain sizes. Microstructures and mechanical properties were discussed. In this Part II contribution, the crystallographic textures and quasi-static magnetic properties of ECAE-processed Hiperco were characterized. The textures were of a simple-shear character defined by partial {110} and <111> fibers inclined relative to the extrusion direction, in agreement with the expectations for simple-shear deformation textures of BCC metals. These textures were observed throughout all processing conditions and only slightlymore » reduced in intensity by subsequent recrystallization heat treatments. Characterization of the magnetic properties revealed a lower coercivity and higher permeability for ECAE-processed Hiperco specimens relative to the conventionally processed and annealed Hiperco bar. In conclusion, the effects of the resultant microstructure and texture on the coercivity and permeability magnetic properties are discussed.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Kustas, Andrew B.; Michael, Joseph R.; Susan, Don F.
In Part I, equal channel angular extrusion (ECAE) was demonstrated as a novel, simple-shear deformation process for producing bulk forms of the low ductility Fe–Co–2V (Hiperco 50A®) soft ferromagnetic alloy with refined grain sizes. Microstructures and mechanical properties were discussed. In this Part II contribution, the crystallographic textures and quasi-static magnetic properties of ECAE-processed Hiperco were characterized. The textures were of a simple-shear character defined by partial {110} and <111> fibers inclined relative to the extrusion direction, in agreement with the expectations for simple-shear deformation textures of BCC metals. These textures were observed throughout all processing conditions and only slightlymore » reduced in intensity by subsequent recrystallization heat treatments. Characterization of the magnetic properties revealed a lower coercivity and higher permeability for ECAE-processed Hiperco specimens relative to the conventionally processed and annealed Hiperco bar. In conclusion, the effects of the resultant microstructure and texture on the coercivity and permeability magnetic properties are discussed.« less
Environmental magnetism and magnetic mapping of urban metallic pollution (Paris, France)
NASA Astrophysics Data System (ADS)
Isambert, Aude; Franke, Christine; Macouin, Mélina; Rousse, Sonia; Philip, Aurélio; de Villeneuve, Sybille Henry
2017-04-01
Airborne pollution in dense urban areas is nowadays a subject of major concern. Fine particulate pollution events are ever more frequent and represent not only an environmental and health but also a real economic issue. In urban atmosphere, the so-called PM2.5 (particulate matter < 2.5 μm in diameter) and ultrafine fractions (< 100 nm) due to combustion, causes many adverse health effects. Environmental magnetic studies of airborne PM collected on air filters or plants have demonstrated their potential to follow the metallic pollution and determine their sources (Sagnotti et al., 2012). In this study, we report on magnetic measurements of traffic-related airborne PM in the city of Paris, France. Two distinct environments were sampled and analyzed along the Seine River: the aquatic environment in studying fluvial bank and river bed sediments and the atmospheric environment by regarding magnetic particles trapped in adjacent tree barks (Platanus hispanica). About 50 sediment samples and 350 bark samples have been collected and analysed to determine their magnetic properties (susceptibility, hysteresis parameters, IRM, frequency-dependent susceptibility) and to estimate the presence and spatial concentration of superparamagnetic or multi-domain particles for each sample type. The bark results allow proposing a high spatial resolution mapping (< 50 m) of magnetic susceptibility and frequency dependent susceptibility on a 30 km long profile along the river. Variations in that profile may be linked to the atmospheric metallic pollution. In addition to that, the sampling of banks and riverbed sediments of the Seine allow a global estimation on the anthropogenic versus detrital and biologic input in the city of Paris. The first results presented here show a general increase of the concentration in magnetic particles from upstream to downstream Paris probably linked to urban pollutions as previously observed for suspended particulate matter (Franke et al. 2009; Kayvantash, 2016). Sagnotti, L., & Winkler, A. (2012). On the magnetic characterization and quantification of the superparamagnetic fraction of traffic-related urban airborne PM in Rome, Italy. Atmospheric environment, 59, 131-140. Franke, C., Kissel, C., Robin, E., Bonté, P., & Lagroix, F. (2009). Magnetic particle characterization in the Seine river system: Implications for the determination of natural versus anthropogenic input. Geochemistry, Geophysics, Geosystems, 10(8). Kayvantash, D., 2016. Characterization of ferruginous particles in the Seine River using environmental magnetism, Ph.D. thesis, MINES ParisTech/LSCE, France.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Sah, Sanjay
Particle accelerators produce beams of high-energy particles, which are used for both fundamental and applied scientific research and are critical to the development of accelerator driven sub-critical reactor systems. An effective magnetic shield is very important to achieve higher quality factor (Qo) of the cryomodule of a particle accelerator. The allowed value of field inside the cavity due to all external fields (particularly the Earth’s magnetic field) is ~15 mG or less. The goal of this PhD dissertation is to comprehensively study the magnetic properties of commonly used magnetic shielding materials at both cryogenic and room temperatures. This knowledge canmore » be used for the enhanced design of magnetic shields of cryomodes (CM) in particle accelerators. To this end, we first studied the temperature dependent magnetization behavior (M-H curves) of Amumetal and A4K under different annealing and deformation conditions. This characterized the effect of stress or deformation induced during the manufacturing processes and subsequent restoration of high permeability with appropriate heat treatment. Next, an energy based stochastic model for temperature dependent anhysteretic magnetization behavior of ferromagnetic materials was proposed and benchmarked against experimental data. We show that this model is able to simulate and explain the magnetic behavior of as rolled, deformed and annealed amumetal and A4K over a large range of temperatures. The experimental results for permeability are then used in a finite element model (FEM) in COMSOL to evaluate the shielding effectiveness of multiple shield designs at room temperature as well as cryogenic temperature. This work could serve as a guideline for future design, development and fabrication of magnetic shields of CMs.« less
Magnetic holes in the solar wind. [(interplanetary magnetic fields)
NASA Technical Reports Server (NTRS)
Turner, J. M.; Burlaga, L. F.; Ness, N. F.; Lemaire, J. F.
1976-01-01
An analysis is presented of high resolution interplanetary magnetic field measurements from the magnetometer on Explorer 43 which showed that low magnetic field intensities in the solar wind at 1 AU occur as distinct depressions or 'holes'. These magnetic holes are new kinetic-scale phenomena, having a characteristic dimension on the order of 20,000 km. They occurred at a rate of 1.5/day in the 18-day time span (March 18 to April 6, 1971) that was analyzed. Most of the magnetic holes are characterized by both a depression in the absolute value of the magnetic field, and a change in the magnetic field direction; some of these are possibly the result of magnetic merging. However, in other cases the magnetic field direction does not change; such holes are not due to magnetic merging, but might be a diamagnetic effect due to localized plasma inhomogeneities.
NASA Astrophysics Data System (ADS)
Dallanave, Edoardo; Kirscher, Uwe; Hauck, Jürgen; Hesse, Reinhard; Bachtadse, Valerian; Wortmann, Ulrich Georg
2018-06-01
The Rhenodanubian Flysch zone (RDF) is a Lower Cretaceous-lower Palaeocene turbidite succession extending for ˜500 km from the Danube at Vienna to the Rhine Valley (Eastern Alps). It consists of calcareous and siliciclastic turbidite systems deposited in a trench abyssal plain. The age of deposition has been estimated through micropalaeontologic dating. However, palaeomagnetic studies constraining the age and the palaeolatitude of deposition of the RDF are still missing. Here, we present palaeomagnetic data from the Early Cretaceous Tristel and Rehbreingraben Formations of the RDF from two localities in the Bavarian Alps (Rehbrein Creek and Lainbach Valley, southern Germany), and from the stratigraphic equivalent of the Falknis Nappe (Liechtenstein). The quality of the palaeomagnetic signal has been assessed by either fold test (FT) or reversal test (RT). Sediments from the Falknis Nappe are characterized by a pervasive syntectonic magnetic overprint as tested by negative FT, and are thus excluded from the study. The sediments of the Rehbreingraben Formation at Rehbrein Creek, with positive RT, straddle magnetic polarity Chron M0r and the younger M΄-1r΄ reverse event, with an age of ˜127-123 Ma (late Barremian-early Aptian). At Lainbach Valley, no polarity reversals have been observed, but a positive FT gives confidence on the reliability of the data. The primary palaeomagnetic directions, after correction for inclination shallowing, allow to precisely constrain the depositional palaeolatitude of the Tristel and Rehbreingraben Formations around ˜28°N. In a palaeogeographic reconstruction of the Alpine Tethys at the Barremian/Aptian boundary, the RDF is located on the western margin of the Briançonnais terrain, which was separated from the European continent by the narrow Valais Ocean.
2013-01-01
Background. Lower ambulatory performance with aging may be related to a reduced oxidative capacity within skeletal muscle. This study examined the associations between skeletal muscle mitochondrial capacity and efficiency with walking performance in a group of older adults. Methods. Thirty-seven older adults (mean age 78 years; 21 men and 16 women) completed an aerobic capacity (VO2 peak) test and measurement of preferred walking speed over 400 m. Maximal coupled (State 3; St3) mitochondrial respiration was determined by high-resolution respirometry in saponin-permeabilized myofibers obtained from percutanous biopsies of vastus lateralis (n = 22). Maximal phosphorylation capacity (ATPmax) of vastus lateralis was determined in vivo by 31P magnetic resonance spectroscopy (n = 30). Quadriceps contractile volume was determined by magnetic resonance imaging. Mitochondrial efficiency (max ATP production/max O2 consumption) was characterized using ATPmax per St3 respiration (ATPmax/St3). Results. In vitro St3 respiration was significantly correlated with in vivo ATPmax (r 2 = .47, p = .004). Total oxidative capacity of the quadriceps (St3*quadriceps contractile volume) was a determinant of VO2 peak (r 2 = .33, p = .006). ATPmax (r 2 = .158, p = .03) and VO2 peak (r 2 = .475, p < .0001) were correlated with preferred walking speed. Inclusion of both ATPmax/St3 and VO2 peak in a multiple linear regression model improved the prediction of preferred walking speed (r 2 = .647, p < .0001), suggesting that mitochondrial efficiency is an important determinant for preferred walking speed. Conclusions. Lower mitochondrial capacity and efficiency were both associated with slower walking speed within a group of older participants with a wide range of function. In addition to aerobic capacity, lower mitochondrial capacity and efficiency likely play roles in slowing gait speed with age. PMID:23051977
Coen, Paul M; Jubrias, Sharon A; Distefano, Giovanna; Amati, Francesca; Mackey, Dawn C; Glynn, Nancy W; Manini, Todd M; Wohlgemuth, Stephanie E; Leeuwenburgh, Christiaan; Cummings, Steven R; Newman, Anne B; Ferrucci, Luigi; Toledo, Frederico G S; Shankland, Eric; Conley, Kevin E; Goodpaster, Bret H
2013-04-01
Lower ambulatory performance with aging may be related to a reduced oxidative capacity within skeletal muscle. This study examined the associations between skeletal muscle mitochondrial capacity and efficiency with walking performance in a group of older adults. Thirty-seven older adults (mean age 78 years; 21 men and 16 women) completed an aerobic capacity (VO2 peak) test and measurement of preferred walking speed over 400 m. Maximal coupled (State 3; St3) mitochondrial respiration was determined by high-resolution respirometry in saponin-permeabilized myofibers obtained from percutanous biopsies of vastus lateralis (n = 22). Maximal phosphorylation capacity (ATPmax) of vastus lateralis was determined in vivo by (31)P magnetic resonance spectroscopy (n = 30). Quadriceps contractile volume was determined by magnetic resonance imaging. Mitochondrial efficiency (max ATP production/max O2 consumption) was characterized using ATPmax per St3 respiration (ATPmax/St3). In vitro St3 respiration was significantly correlated with in vivo ATPmax (r (2) = .47, p = .004). Total oxidative capacity of the quadriceps (St3*quadriceps contractile volume) was a determinant of VO2 peak (r (2) = .33, p = .006). ATPmax (r (2) = .158, p = .03) and VO2 peak (r (2) = .475, p < .0001) were correlated with preferred walking speed. Inclusion of both ATPmax/St3 and VO2 peak in a multiple linear regression model improved the prediction of preferred walking speed (r (2) = .647, p < .0001), suggesting that mitochondrial efficiency is an important determinant for preferred walking speed. Lower mitochondrial capacity and efficiency were both associated with slower walking speed within a group of older participants with a wide range of function. In addition to aerobic capacity, lower mitochondrial capacity and efficiency likely play roles in slowing gait speed with age.
Liu, Qi; Chen, Lizhou; Li, Fei; Chen, Ying; Guo, Lanting; Gong, Qiyong; Huang, Xiaoqi
2016-06-01
Attention-deficit/hyperactivity disorder(ADHD)is one of the most common neuro-developmental disorders occurring in childhood,characterized by symptoms of age-inappropriate inattention,hyperactivity/impulsivity,and the prevalence is higher in boys.Although gray matter volume deficits have been frequently reported for ADHD children via structural magnetic resonance imaging,few of them had specifically focused on male patients.The present study aimed to explore the alterations of gray matter volumes in medicated-naive boys with ADHD via a relatively new voxel-based morphometry technique.According to the criteria of DSM-IV-TR,43medicated-naive ADHD boys and 44age-matched healthy boys were recruited.The magnetic resonance image(MRI)scan was performed via a 3T MRI system with three-dimensional(3D)spoiled gradient recalled echo(SPGR)sequence.Voxel-based morphometry with diffeomorphic anatomical registration through exponentiated lie algebra in SPM8 was used to preprocess the3DT1-weighted images.To identify gray matter volume differences between the ADHD and the controls,voxelbased analysis of whole brain gray matter volumes between two groups were done via two sample t-test in SPM8 with age as covariate,threshold at P<0.001.Finally,compared to the controls,significantly reduced gray matter volumes were identified in the right orbitofrontal cortex(peak coordinates[-2,52,-25],t=4.01),and bilateral hippocampus(Left:peak coordinates[14,0,-18],t=3.61;Right:peak coordinates[-14,15,-28],t=3.64)of ADHD boys.Our results demonstrated obvious reduction of whole brain gray matter volumes in right orbitofrontal cortex and bilateral hippocampus in boys with ADHD.This suggests that the abnormalities of prefrontal-hippocampus circuit may be the underlying cause of the cognitive dysfunction and abnormal behavioral inhibition in medicatednaive boys with ADHD.
NASA Astrophysics Data System (ADS)
Schnepp, Elisabeth; Pucher, Rudolf; Goedicke, Christian; Manzano, Ana; Müller, Uwe; Lanos, Philippe
2003-02-01
A record of about 450 years of geomagnetic secular variation is presented from a single archaeological site in Lübeck (Germany) where a sequence of 25 bread oven floors has been preserved in a bakery from medieval times until today. The age dating of the oven-floor sequence is based on historical documents, 14C-dating and thermoluminescence dating. It confines the time interval from about 1300 to 1800 A.D. Paleomagnetic directions have been determined from each oven floor by means of 198 oriented hand samples. After alternating field as well as thermal demagnetization experiments, the characteristic remanent magnetization direction was obtained using principal component analysis. The mean directions of 24 oven floors are characterized by high Fisherian precision parameters (>146) and small α95 confidence limits (1.2°-4.6°). For obtaining a smooth curve of geomagnetic secular variation for Lübeck, a spherical spline function was fitted to the data using a Bayesian approach, which considers not only the obtained ages, but also stratigraphic order. Correlation with historical magnetic records suggests that the age estimation for the upper 10 layers was too young and must date from the end of the sixteenth to the mid of the eighteenth century. For the lowermost 14 layers, dating is reliable and provides a secular variation curve for Germany. The inclination shows a minimum in the fourteenth century and then increases by more than 10°. Declination shows a local minimum around 1400 A.D. followed by a maximum in the seventeenth century. This is followed by the movement of declination about 30° to western directions.
Al-Shafei, Ahmad I M; Wise, R G; Gresham, G A; Bronns, G; Carpenter, T A; Hall, L D; Huang, Christopher L-H
2002-01-01
A non-invasive cine magnetic resonance imaging (MRI) technique was developed to allow, for the first time, detection and characterization of chronic changes in myocardial tissue volume and the effects upon these of treatment by the angiotensin-converting enzyme (ACE) inhibitor captopril in streptozotocin (STZ)-diabetic male Wistar rats. Animals that had been made diabetic at the ages of 7, 10 and 13 weeks and a captopril-treated group of animals made diabetic at the age of 7 weeks were scanned. The findings were compared with the results from age-matched controls. All animal groups (n = 4 animals in each) were consistently scanned at 16 weeks. Left and right ventricular myocardial volumes were reconstructed from complete data sets of left and right ventricular transverse sections which covered systole and most of diastole using twelve equally incremented time points through the cardiac cycle. The calculated volumes remained consistent through all twelve time points of the cardiac cycle in all five experimental groups and agreed with the corresponding post-mortem determinations. These gave consistent myocardial densities whose values could additionally be corroborated by previous reports, confirming the validity of the quantitative MRI results and analysis. The myocardial volumes were conserved in animals whose diabetes was induced at 13 weeks but were significantly increased relative to body weight in animals made diabetic at 7 and 10 weeks. Captopril treatment, which was started immediately after induction of diabetes, prevented the development of this relative hypertrophy in both the left and right ventricles. We have thus introduced and validated quantitative MRI methods in a demonstration, for the first time, of chronic myocardial changes in both the right and left ventricles of STZ-diabetic rats and their prevention by the ACE inhibitor captopril. PMID:11790818
Magnetic FB injuries: an old yet unresolved hazard.
Gregori, Dario; Morra, Bruno; Gulati, Achal
2012-05-14
Among foreign bodies causing injuries in children, magnets have been reported to cause serious complications and being life-threatening. The aim of this study is to design a risk profile and an epidemiological figure of such injuries, for being used for prevention. Data on 366 injuries have been collected from public surveillance databases and from published scientific literature, and compared with the data of the Susy Safe registry, which is a pan-European registry of foreign bodies injuries co-funded by the European Commission. A median age of 48 months was observed, with a 63% prevalence of males is characterizing the injuries. Magnets have a median volume of 87.9 mm(3) vs the median volume of 41.86 mm(3) of the overall foreign bodies of the Susy Safe registry). Only 43% of the magnets were involving only on piece or objects, with a median number of two objects per injury, up to a maximum of 32 objects. Children are referred to the medical care system with a median delay of 3 days after onset of symptoms. Median length of stay in the hospital was 7 days with respect to 1 day as in the Susy Safe registry. Most of complications, and event the death of a child can be eventually re-conducted to either or both a delay in patient referral or appropriate diagnosis. Thus, it is an absolute priority that an information initiative is taken toward families and emergency doctors to avoid unnecessarily delays respectively in patient referral and in diagnosis. Copyright © 2012. Published by Elsevier Ireland Ltd.
NASA Astrophysics Data System (ADS)
Macrì, Patrizia; Capraro, Luca; Ferretti, Patrizia; Scarponi, Daniele
2018-05-01
High-resolution palaeomagnetic and rock magnetic investigations on the Valle di Manche section (Crotone Basin, Calabria, Southern Italy) provide a detailed record of the Matuyama-Brunhes (M-B) reversal that, to our best knowledge, is the only available record of the last geomagnetic reversal for the Mediterranean on-land marine stratigraphy. The M-B transition can be pinpointed precisely, as it develops within a 3-cm-thick interval located just above a prominent tephra layer (the "Pitagora ash") where the sedimentation rates are about 27 cm/kyr. Demagnetization analyses indicate a stable palaeomagnetic behaviour throughout the section for both normal and reversed polarity directions, with demagnetization vectors aligned toward the origin of Zijderveld diagrams after the removal of a small viscous low-coercivity remanence component. In the lower part of the studied interval, some samples acquired a spurious gyromagnetic remanent magnetization (GRM) during AF demagnetization in high fields. Rock magnetic analyses confirm that magnetite is the main magnetic carrier for all measured specimens, which also have an abundant paramagnetic fraction. Only the lower part of the record, well below the M-B boundary, is characterized by a downward-increasing presence of iron sulphides (greigite). According to our chronology, which is based on a robust, cross-validated age model, the final reverse-to-normal directional change of the M-B transition occurred at ca. 786.9 ± 5 ka (error includes uncertainty in orbital tuning) and was very rapid, of the order of 100 years or less.
Study of magnetization switching in coupled magnetic nanostructured systems
NASA Astrophysics Data System (ADS)
Radu, Cosmin
A study of magnetization dynamics experiments in nanostructured materials using the rf susceptibility tunnel diode oscillator (TDO) method is presented along with a extensive theoretical analysis. An original, computer controlled experimental setup that measures the change in susceptibility with the variation in external magnetic field and sample temperature was constructed. The TDO-based experiment design and construction is explained in detail, showing all the elements of originality. This experimental technique has proven reliable for characterizing samples with uncoupled magnetic structure and various magnetic anisotropies like: CrO2, FeCo/IrMn and Co/SiO2 thin films. The TDO was subsequently used to explore the magnetization switching in coupled magnetic systems, like synthetic antiferromagnet (SAF) structures. Magnetoresistive random access memory (MRAM) is an important example of devices where the use of SAF structure is essential. To support the understanding of the SAF magnetic behavior, its configuration and application are reviewed and more details are provided in an appendix. Current problems in increasing the scalability and decreasing the error rate of MRAM devices are closely connected to the switching properties of the SAF structures. Several theoretical studies that were devoted to the understanding of the concepts of SAF critical curve are reviewed. As one can notice, there was no experimental determination of SAF critical curve, due to the difficulties in characterizing a magnetic coupled structure. Depending of the coupling strength between the two ferromagnetic layers, on the SAF critical curve one distinguishes several new features, inexistent in the case of uncoupled systems. Knowing the configuration of the SAF critical curve is of great importance in order to control its switching characteristics. For the first time a method of experimentally recording the critical curve for SAF is proposed in this work. In order to overcome technological limitations, a new way of recording the critical curve by using an additional magnetic bias field was explored. Keywords: magnetization dynamics, magnetic susceptibility, tunnel diode oscillator, critical curve, synthetic antiferromagnet, coupled magnetic structures, MRAM.
Age-related apparent diffusion coefficient changes in the normal brain.
Watanabe, Memi; Sakai, Osamu; Ozonoff, Al; Kussman, Steven; Jara, Hernán
2013-02-01
To measure the mean diffusional age-related changes of the brain over the full human life span by using diffusion-weighted spin-echo single-shot echo-planar magnetic resonance (MR) imaging and sequential whole-brain apparent diffusion coefficient (ADC) histogram analysis and, secondarily, to build mathematical models of these normal age-related changes throughout human life. After obtaining institutional review board approval, a HIPAA-compliant retrospective search was conducted for brain MR imaging studies performed in 2007 for various clinical indications. Informed consent was waived. The brain data of 414 healthy subjects (189 males and 225 females; mean age, 33.7 years; age range, 2 days to 89.3 years) were obtained with diffusion-weighted spin-echo single-shot echo-planar MR imaging. ADC histograms of the whole brain were generated. ADC peak values, histogram widths, and intracranial volumes were plotted against age, and model parameters were estimated by using nonlinear regression. Four different stages were identified for aging changes in ADC peak values, as characterized by specific mathematical terms: There were age-associated exponential decays for the maturation period and the development period, a constant term for adulthood, and a linear increase for the senescence period. The age dependency of ADC peak value was simulated by using four-term six-coefficient function, including biexponential and linear terms. This model fit the data very closely (R(2) = 0.91). Brain diffusivity as a whole demonstrated age-related changes through four distinct periods of life. These results could contribute to establishing an ADC baseline of the normal brain, covering the full human life span.
Liu, Haiyi; Sun, Jianfei; Wang, Haoyao; Wang, Peng; Song, Lina; Li, Yang; Chen, Bo; Zhang, Yu; Gu, Ning
2015-06-08
A kinetics-based method is proposed to quantitatively characterize the collective magnetization of colloidal magnetic nanoparticles. The method is based on the relationship between the magnetic force on a colloidal droplet and the movement of the droplet under a gradient magnetic field. Through computational analysis of the kinetic parameters, such as displacement, velocity, and acceleration, the magnetization of colloidal magnetic nanoparticles can be calculated. In our experiments, the values measured by using our method exhibited a better linear correlation with magnetothermal heating, than those obtained by using a vibrating sample magnetometer and magnetic balance. This finding indicates that this method may be more suitable to evaluate the collective magnetism of colloidal magnetic nanoparticles under low magnetic fields than the commonly used methods. Accurate evaluation of the magnetic properties of colloidal nanoparticles is of great importance for the standardization of magnetic nanomaterials and for their practical application in biomedicine. © 2015 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.
NASA Astrophysics Data System (ADS)
Sander, D.; Valenzuela, S. O.; Makarov, D.; Marrows, C. H.; Fullerton, E. E.; Fischer, P.; McCord, J.; Vavassori, P.; Mangin, S.; Pirro, P.; Hillebrands, B.; Kent, A. D.; Jungwirth, T.; Gutfleisch, O.; Kim, C. G.; Berger, A.
2017-09-01
Building upon the success and relevance of the 2014 Magnetism Roadmap, this 2017 Magnetism Roadmap edition follows a similar general layout, even if its focus is naturally shifted, and a different group of experts and, thus, viewpoints are being collected and presented. More importantly, key developments have changed the research landscape in very relevant ways, so that a novel view onto some of the most crucial developments is warranted, and thus, this 2017 Magnetism Roadmap article is a timely endeavour. The change in landscape is hereby not exclusively scientific, but also reflects the magnetism related industrial application portfolio. Specifically, Hard Disk Drive technology, which still dominates digital storage and will continue to do so for many years, if not decades, has now limited its footprint in the scientific and research community, whereas significantly growing interest in magnetism and magnetic materials in relation to energy applications is noticeable, and other technological fields are emerging as well. Also, more and more work is occurring in which complex topologies of magnetically ordered states are being explored, hereby aiming at a technological utilization of the very theoretical concepts that were recognised by the 2016 Nobel Prize in Physics. Given this somewhat shifted scenario, it seemed appropriate to select topics for this Roadmap article that represent the three core pillars of magnetism, namely magnetic materials, magnetic phenomena and associated characterization techniques, as well as applications of magnetism. While many of the contributions in this Roadmap have clearly overlapping relevance in all three fields, their relative focus is mostly associated to one of the three pillars. In this way, the interconnecting roles of having suitable magnetic materials, understanding (and being able to characterize) the underlying physics of their behaviour and utilizing them for applications and devices is well illustrated, thus giving an accurate snapshot of the world of magnetism in 2017. The article consists of 14 sections, each written by an expert in the field and addressing a specific subject on two pages. Evidently, the depth at which each contribution can describe the subject matter is limited and a full review of their statuses, advances, challenges and perspectives cannot be fully accomplished. Also, magnetism, as a vibrant research field, is too diverse, so that a number of areas will not be adequately represented here, leaving space for further Roadmap editions in the future. However, this 2017 Magnetism Roadmap article can provide a frame that will enable the reader to judge where each subject and magnetism research field stands overall today and which directions it might take in the foreseeable future. The first material focused pillar of the 2017 Magnetism Roadmap contains five articles, which address the questions of atomic scale confinement, 2D, curved and topological magnetic materials, as well as materials exhibiting unconventional magnetic phase transitions. The second pillar also has five contributions, which are devoted to advances in magnetic characterization, magneto-optics and magneto-plasmonics, ultrafast magnetization dynamics and magnonic transport. The final and application focused pillar has four contributions, which present non-volatile memory technology, antiferromagnetic spintronics, as well as magnet technology for energy and bio-related applications. As a whole, the 2017 Magnetism Roadmap article, just as with its 2014 predecessor, is intended to act as a reference point and guideline for emerging research directions in modern magnetism.
O'Rourke, Declan J; Ryan, Stephanie; Salomons, Gajja; Jakobs, Cornelis; Monavari, Ahmad; King, Mary D
2009-05-01
Guanidinoacetate methyltransferase (GAMT) deficiency is a disorder of creatine biosynthesis, characterized by early-onset learning disability and epilepsy in most affected children. Severe expressive language delay is a constant feature even in the mildest clinical phenotypes.We report the clinical, biochemical, imaging, and treatment data of two female siblings (18y and 13y) with an unusual phenotype of GAMT deficiency. The oldest sibling had subacute onset of a movement disorder at age 17 years, later than has been previously reported. The younger sibling had better language skills than previously described in this disorder. After treatment with creatine, arginine restriction and ornithine-supplemented diet, seizure severity and movement disorder were reduced but cognition did not improve. This report confirms that GAMT deficiency, a heterogeneous, potentially treatable disorder, detected by increased levels of guanidinoacetate in body fluids (e.g. plasma or urine) or by an abnormal creatine peak on magnetic resonance spectroscopy, should be considered in patients of any age with unexplained, apparently static learning disability and epilepsy.
Magnetic resonance imaging in Tietze's syndrome.
Volterrani, L; Mazzei, M A; Giordano, N; Nuti, R; Galeazzi, M; Fioravanti, A
2008-01-01
To evaluate the usefulness of magnetic resonance imaging (MRI) in Tietze's syndrome which, to our knowledge, has not previously been reported in the literature. Twelve consecutive outpatients with clinical features of Tietze's syndrome underwent evaluation, including the anamnesis, clinical general examination, clinical evaluation of costosternal and sternoclavicular joints (SCJ) and biochemical and instrumental investigations. Twenty normal subjects age- and sex-matched to the patients' group were examined in a similar manner. MRI of costosternal and SCJ was performed using a 1.5 Tesla unit (Gyroscan NT 1.5 Philips, The Netherlands and GE Signa Excite HD, GE Healthcare, Milwaukee, Wis., USA). The MRI pattern of primary Tietze's syndrome was characterized as follows: enlargement and thickening of cartilage at the site of complaint (12/12 patients); focal or widespread increased signal intensities of affected cartilage on both TSE T2-weighted and STIR or FAT SAT images (10/12 patients); bone marrow oedema in the subcondral bone (5/12 patients); vivid gadolinium uptake in the areas of thickened cartilage, in the subcondral bone marrow and/or in capsule and ligaments (10/12, 4/12 and 7/12 patients respectively). Magnetic resonance is an excellent technique to evidence both the cartilage and bone abnormalities, therefore it represents the elective method in the investigation of primary Tietze's syndrome, due to its high sensitivity, diagnostic reliability and biological advantages thanks to the lack of ionizing radiation.
Radioactive and magnetic investigations
NASA Technical Reports Server (NTRS)
Heye, D.; Beiersdorf, H.
1979-01-01
Age and growth pattern determination of manganese nodules were explored. Two methods are discussed: (1) measurement of the presence of radioactive iodine isotopes; which is effective only up to 3.105 years, and (2) measurements of magnetism. The growth rates of three nodules were determined. The surface of the nodule was recent, and the overall age of the nodule could be determined with accuracy of better than 30%. Measurement of paleomagnetic effect was attempted to determine wider age ranges, however, the measured sign changes could not be interpreted as paleomagnetic reversals.
Rippled graphene in an in-plane magnetic field: effects of a random vector potential.
Lundeberg, Mark B; Folk, Joshua A
2010-10-01
We report measurements of the effects of a random vector potential generated by applying an in-plane magnetic field to a graphene flake. Magnetic flux through the ripples cause orbital effects: Phase-coherent weak localization is suppressed, while quasirandom Lorentz forces lead to anisotropic magnetoresistance. Distinct signatures of these two effects enable the ripple size to be characterized.
Tunable magnetic vortex resonance in a potential well
NASA Astrophysics Data System (ADS)
Warnicke, P.; Wohlhüter, P.; Suszka, A. K.; Stevenson, S. E.; Heyderman, L. J.; Raabe, J.
2017-11-01
We use frequency-resolved x-ray microscopy to fully characterize the potential well of a magnetic vortex in a soft ferromagnetic permalloy square. The vortex core is excited with magnetic broadband pulses and simultaneously displaced with a static magnetic field. We observe a frequency increase (blueshift) in the gyrotropic mode of the vortex core with increasing bias field. Supported by micromagnetic simulations, we show that this frequency increase is accompanied by internal deformation of the vortex core. The ability to modify the inner structure of the vortex core provides a mechanism to control the dynamics of magnetic vortices.
Effects of a vertical magnetic field on particle confinement in a magnetized plasma torus.
Müller, S H; Fasoli, A; Labit, B; McGrath, M; Podestà, M; Poli, F M
2004-10-15
The particle confinement in a magnetized plasma torus with superimposed vertical magnetic field is modeled and measured experimentally. The formation of an equilibrium characterized by a parallel plasma current canceling out the grad B and curvature drifts is described using a two-fluid model. Characteristic response frequencies and relaxation rates are calculated. The predictions for the particle confinement time as a function of the vertical magnetic field are verified in a systematic experimental study on the TORPEX device, including the existence of an optimal vertical field and the anticorrelation between confinement time and density.
Methods for the fabrication of thermally stable magnetic tunnel junctions
Chang, Y Austin [Middleton, WI; Yang, Jianhua J [Madison, WI; Ladwig, Peter F [Hutchinson, MN
2009-08-25
Magnetic tunnel junctions and method for making the magnetic tunnel junctions are provided. The magnetic tunnel junctions are characterized by a tunnel barrier oxide layer sandwiched between two ferromagnetic layers. The methods used to fabricate the magnetic tunnel junctions are capable of completely and selectively oxidizing a tunnel junction precursor material using an oxidizing gas containing a mixture of gases to provide a tunnel junction oxide without oxidizing the adjacent ferromagnetic materials. In some embodiments the gas mixture is a mixture of CO and CO.sub.2 or a mixture of H.sub.2 and H.sub.2O.
Low temperature physical properties of Co-35Ni-20Cr-10Mo alloy MP35N®
NASA Astrophysics Data System (ADS)
Lu, J.; Toplosky, V. J.; Goddard, R. E.; Han, K.
2017-09-01
Multiphase Co-35Ni-20Cr-10Mo alloy MP35N® is a high strength alloy with excellent corrosion resistance. Its applications span chemical, medical, and food processing industries. Thanks to its high modulus and high strength, it found applications in reinforcement of ultra-high field pulsed magnets. Recently, it has also been considered for reinforcement in superconducting wires used in ultra-high field superconducting magnets. For these applications, accurate measurement of its physical properties at cryogenic temperatures is very important. In this paper, physical properties including electrical resistivity, specific heat, thermal conductivity, and magnetization of as-received and aged samples are measured from 2 to 300 K. The electrical resistivity of the aged sample is slightly higher than the as-received sample, both showing a weak linear temperature dependence in the entire range of 2-300 K. The measured specific heat Cp of 430 J/kg-K at 295 K agrees with a theoretical prediction, but is significantly smaller than the values in the literature. The thermal conductivity between 2 and 300 K is in good agreement with the literature which is only available above 77 K. Magnetic property of MP35N® changes significantly with aging. The as-received sample exhibits Curie paramagnetism with a Curie constant C = 0.175 K. While the aged sample contains small amounts of a ferromagnetic phase even at room temperature. The measured MP35N® properties will be useful for the engineering design of pulsed magnets and superconducting magnets using MP35N® as reinforcement.
Mapping of magnetic chrons: paleomagnetic polarity map of East Iceland, 0-13 Myr
NASA Astrophysics Data System (ADS)
Helgason, Johann
2016-04-01
Through data on palaeomagnetism, stratigraphy and radiometric age dating an immense database on magnetic chrons has been established for the lava succession in Iceland (e.g. Kristjánsson, 2008). Correlation of magnetic chrons with the geomagnetic time scale provides a reasonable age estimate for vast stratigraphic sequences. The basalt lava succession in Iceland has a thickness of tens of kilometers. The magnetostratigraphic data offer, through the help of paleomagnetism and radiometric dating, a detailed timing of events in the evolution of the Iceland mantle plume region. Yet a magnetic polarity map for Iceland has been lacking but during the last 50 years, comprehensive stratigraphic mapping has paved the way for a magnetic polarity map in various parts of Iceland. Here, such a map is presented for a segment of East Iceland, i.e. for lavas ranging in age from 0 to 13 M yr. The map is a compilation based on various studies into the cliff section and stratigraphic work performed by numerous research initiatives, both in relation to hydroelectric research as well as academic projects. References: Kristjánsson, L., 2008. Paleomagnetic research on Icelandic lava flows. Jökull, 58, 101-116. Helgason, J., Duncan, R.A., Franzson, H., Guðmundsson, Á., and M. Riishuus., 2015. Magnetic polarity map of Akrafjall and Skarðsheiði and new 40Ar-39Ar age dating from West Iceland., Presentation at the spring conference of the Icelandic Geological Society, held on March 13th 2015 at the University of Iceland.
Holocene Paleolimnological Records from Thule, Northwestern Greenland
NASA Astrophysics Data System (ADS)
Corbett, L.; Osterberg, E. C.; Kelly, M. A.; Axford, Y.
2012-12-01
Assessing Holocene climatic and environmental variability around the margin of the Greenland Ice Sheet provides important information against which to compare ice sheet margin fluctuations. Here, we report preliminary results from ongoing research in northwestern Greenland. We present records of physical properties of lake sediments and use these to make inferences about the evolution of the lake and its surroundings over the latter half of the Holocene. We collected two sediment cores, 90 and 72 cm in length, from a small (surface area ~0.3 km2), shallow (maximum depth ~4.5 m) lake at 76°33'40''N 68°26'31''W near Thule Air Base in July 2012. The length of the cores was limited by the length of the core barrel and does not reflect the total thickness of sediment in the lake. The lake is situated within the glacial limit and likely formed subsequent to deglaciation of the region during early Holocene time. No glaciers exist within the lake's catchment today; the primary modern source of sediment is a perennial inflow from the west. We developed a preliminary depth-age model using radiocarbon ages of terrestrial organic macrofossils. Thus far, we have analyzed the sediments for magnetic susceptibility and loss-on-ignition. A radiocarbon age of 6069 ± 90 cal yr BP at the base of the core indicates that the sediments preserve a continuous record of middle to late Holocene conditions. The top of both cores consists of a thick (~12 cm) layer of dark gray unlaminated sediments, while the rest of the material in both cores is lighter brown to olive, finely laminated sediment. The upper layer is characterized by low water content (<25%), low loss-on-ignition (<5%), and high magnetic susceptibility (~150-250 x10-6). Conversely, the laminated sediments beneath have higher water content (~40-50%), higher loss-on-ignition (~5-10%), and much lower magnetic susceptibility (<50 x10-6). We hypothesize that the upper, less organic unit may represent a single event in the lake's recent history. We are refining the depth-age model with more radiocarbon ages, measuring grain size and carbon to nitrogen ratios of the sediments, and evaluating possible linkages between the sediment physical properties and precipitation as recorded by annual accumulation in ice cores in northwestern Greenland and Arctic Canada. This project will provide a foundation for future work in Thule investigating Holocene fluctuations of local ice cap and ice sheet margin positions.