Sample records for magnetic random access

  1. Improved Writing-Conductor Designs For Magnetic Memory

    NASA Technical Reports Server (NTRS)

    Wu, Jiin-Chuan; Stadler, Henry L.; Katti, Romney R.

    1994-01-01

    Writing currents reduced to practical levels. Improved conceptual designs for writing conductors in micromagnet/Hall-effect random-access integrated-circuit memory reduces electrical current needed to magnetize micromagnet in each memory cell. Basic concept of micromagnet/Hall-effect random-access memory presented in "Magnetic Analog Random-Access Memory" (NPO-17999).

  2. Integrated semiconductor-magnetic random access memory system

    NASA Technical Reports Server (NTRS)

    Katti, Romney R. (Inventor); Blaes, Brent R. (Inventor)

    2001-01-01

    The present disclosure describes a non-volatile magnetic random access memory (RAM) system having a semiconductor control circuit and a magnetic array element. The integrated magnetic RAM system uses CMOS control circuit to read and write data magnetoresistively. The system provides a fast access, non-volatile, radiation hard, high density RAM for high speed computing.

  3. Garnet Random-Access Memory

    NASA Technical Reports Server (NTRS)

    Katti, Romney R.

    1995-01-01

    Random-access memory (RAM) devices of proposed type exploit magneto-optical properties of magnetic garnets exhibiting perpendicular anisotropy. Magnetic writing and optical readout used. Provides nonvolatile storage and resists damage by ionizing radiation. Because of basic architecture and pinout requirements, most likely useful as small-capacity memory devices.

  4. Magnet/Hall-Effect Random-Access Memory

    NASA Technical Reports Server (NTRS)

    Wu, Jiin-Chuan; Stadler, Henry L.; Katti, Romney R.

    1991-01-01

    In proposed magnet/Hall-effect random-access memory (MHRAM), bits of data stored magnetically in Perm-alloy (or equivalent)-film memory elements and read out by using Hall-effect sensors to detect magnetization. Value of each bit represented by polarity of magnetization. Retains data for indefinite time or until data rewritten. Speed of Hall-effect sensors in MHRAM results in readout times of about 100 nanoseconds. Other characteristics include high immunity to ionizing radiation and storage densities of order 10(Sup6)bits/cm(Sup 2) or more.

  5. Non-volatile magnetic random access memory

    NASA Technical Reports Server (NTRS)

    Katti, Romney R. (Inventor); Stadler, Henry L. (Inventor); Wu, Jiin-Chuan (Inventor)

    1994-01-01

    Improvements are made in a non-volatile magnetic random access memory. Such a memory is comprised of an array of unit cells, each having a Hall-effect sensor and a thin-film magnetic element made of material having an in-plane, uniaxial anisotropy and in-plane, bipolar remanent magnetization states. The Hall-effect sensor is made more sensitive by using a 1 m thick molecular beam epitaxy grown InAs layer on a silicon substrate by employing a GaAs/AlGaAs/InAlAs superlattice buffering layer. One improvement avoids current shunting problems of matrix architecture. Another improvement reduces the required magnetizing current for the micromagnets. Another improvement relates to the use of GaAs technology wherein high electron-mobility GaAs MESFETs provide faster switching times. Still another improvement relates to a method for configuring the invention as a three-dimensional random access memory.

  6. Integrated, nonvolatile, high-speed analog random access memory

    NASA Technical Reports Server (NTRS)

    Katti, Romney R. (Inventor); Wu, Jiin-Chuan (Inventor); Stadler, Henry L. (Inventor)

    1994-01-01

    This invention provides an integrated, non-volatile, high-speed random access memory. A magnetically switchable ferromagnetic or ferrimagnetic layer is sandwiched between an electrical conductor which provides the ability to magnetize the magnetically switchable layer and a magneto resistive or Hall effect material which allows sensing the magnetic field which emanates from the magnetization of the magnetically switchable layer. By using this integrated three-layer form, the writing process, which is controlled by the conductor, is separated from the storage medium in the magnetic layer and from the readback process which is controlled by the magnetoresistive layer. A circuit for implementing the memory in CMOS or the like is disclosed.

  7. Vortex-Core Reversal Dynamics: Towards Vortex Random Access Memory

    NASA Astrophysics Data System (ADS)

    Kim, Sang-Koog

    2011-03-01

    An energy-efficient, ultrahigh-density, ultrafast, and nonvolatile solid-state universal memory is a long-held dream in the field of information-storage technology. The magnetic random access memory (MRAM) along with a spin-transfer-torque switching mechanism is a strong candidate-means of realizing that dream, given its nonvolatility, infinite endurance, and fast random access. Magnetic vortices in patterned soft magnetic dots promise ground-breaking applications in information-storage devices, owing to the very stable twofold ground states of either their upward or downward core magnetization orientation and plausible core switching by in-plane alternating magnetic fields or spin-polarized currents. However, two technologically most important but very challenging issues --- low-power recording and reliable selection of each memory cell with already existing cross-point architectures --- have not yet been resolved for the basic operations in information storage, that is, writing (recording) and readout. Here, we experimentally demonstrate a magnetic vortex random access memory (VRAM) in the basic cross-point architecture. This unique VRAM offers reliable cell selection and low-power-consumption control of switching of out-of-plane core magnetizations using specially designed rotating magnetic fields generated by two orthogonal and unipolar Gaussian-pulse currents along with optimized pulse width and time delay. Our achievement of a new device based on a new material, that is, a medium composed of patterned vortex-state disks, together with the new physics on ultrafast vortex-core switching dynamics, can stimulate further fruitful research on MRAMs that are based on vortex-state dot arrays.

  8. Nonvolatile GaAs Random-Access Memory

    NASA Technical Reports Server (NTRS)

    Katti, Romney R.; Stadler, Henry L.; Wu, Jiin-Chuan

    1994-01-01

    Proposed random-access integrated-circuit electronic memory offers nonvolatile magnetic storage. Bits stored magnetically and read out with Hall-effect sensors. Advantages include short reading and writing times and high degree of immunity to both single-event upsets and permanent damage by ionizing radiation. Use of same basic material for both transistors and sensors simplifies fabrication process, with consequent benefits in increased yield and reduced cost.

  9. Non-volatile, high density, high speed, Micromagnet-Hall effect Random Access Memory (MHRAM)

    NASA Technical Reports Server (NTRS)

    Wu, Jiin C.; Katti, Romney R.; Stadler, Henry L.

    1991-01-01

    The micromagnetic Hall effect random access memory (MHRAM) has the potential of replacing ROMs, EPROMs, EEPROMs, and SRAMs because of its ability to achieve non-volatility, radiation hardness, high density, and fast access times, simultaneously. Information is stored magnetically in small magnetic elements (micromagnets), allowing unlimited data retention time, unlimited numbers of rewrite cycles, and inherent radiation hardness and SEU immunity, making the MHRAM suitable for ground based as well as spaceflight applications. The MHRAM device design is not affected by areal property fluctuations in the micromagnet, so high operating margins and high yield can be achieved in large scale integrated circuit (IC) fabrication. The MHRAM has short access times (less than 100 nsec). Write access time is short because on-chip transistors are used to gate current quickly, and magnetization reversal in the micromagnet can occur in a matter of a few nanoseconds. Read access time is short because the high electron mobility sensor (InAs or InSb) produces a large signal voltage in response to the fringing magnetic field from the micromagnet. High storage density is achieved since a unit cell consists only of two transistors and one micromagnet Hall effect element. By comparison, a DRAM unit cell has one transistor and one capacitor, and a SRAM unit cell has six transistors.

  10. Ames Lab 101: Ultrafast Magnetic Switching

    ScienceCinema

    Wang; Jigang

    2018-01-01

    Ames Laboratory physicists have found a new way to switch magnetism that is at least 1000 times faster than currently used in magnetic memory technologies. Magnetic switching is used to encode information in hard drives, magnetic random access memory and other computing devices. The discovery potentially opens the door to terahertz and faster memory speeds.

  11. Spin-transfer-torque efficiency enhanced by edge-damage of perpendicular magnetic random access memories

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Song, Kyungmi; Lee, Kyung-Jin, E-mail: kj-lee@korea.ac.kr; Department of Materials Science and Engineering, Korea University, Seoul 136-713

    2015-08-07

    We numerically investigate the effect of magnetic and electrical damages at the edge of a perpendicular magnetic random access memory (MRAM) cell on the spin-transfer-torque (STT) efficiency that is defined by the ratio of thermal stability factor to switching current. We find that the switching mode of an edge-damaged cell is different from that of an undamaged cell, which results in a sizable reduction in the switching current. Together with a marginal reduction of the thermal stability factor of an edge-damaged cell, this feature makes the STT efficiency large. Our results suggest that a precise edge control is viable formore » the optimization of STT-MRAM.« less

  12. Spin-transfer torque switched magnetic tunnel junctions in magnetic random access memory

    NASA Astrophysics Data System (ADS)

    Sun, Jonathan Z.

    2016-10-01

    Spin-transfer torque (or spin-torque, or STT) based magnetic tunnel junction (MTJ) is at the heart of a new generation of magnetism-based solid-state memory, the so-called spin-transfer-torque magnetic random access memory, or STT-MRAM. Over the past decades, STT-based switchable magnetic tunnel junction has seen progress on many fronts, including the discovery of (001) MgO as the most favored tunnel barrier, which together with (bcc) Fe or FeCo alloy are yielding best demonstrated tunnel magneto-resistance (TMR); the development of perpendicularly magnetized ultrathin CoFeB-type of thin films sufficient to support high density memories with junction sizes demonstrated down to 11nm in diameter; and record-low spin-torque switching threshold current, giving best reported switching efficiency over 5 kBT/μA. Here we review the basic device properties focusing on the perpendicularly magnetized MTJs, both in terms of switching efficiency as measured by sub-threshold, quasi-static methods, and of switching speed at super-threshold, forced switching. We focus on device behaviors important for memory applications that are rooted in fundamental device physics, which highlights the trade-off of device parameters for best suitable system integration.

  13. Optical mass memories

    NASA Technical Reports Server (NTRS)

    Bailey, G. A.

    1976-01-01

    Optical and magnetic variants in the design of trillion-bit read/write memories are compared and tabulated. Components and materials suitable for a random access read/write nonmoving memory system are examined, with preference given to holography and photoplastic materials. Advantages and deficiencies of photoplastics are reviewed. Holographic page composer design, essential features of an optical memory with no moving parts, fiche-oriented random access memory design, and materials suitable for an efficient photoplastic fiche are considered. The optical variants offer advantages in lower volume and weight at data transfer rates near 1 Mbit/sec, but power drain is of the same order as for the magnetic variants (tape memory, disk memory). The mechanical properties of photoplastic film materials still leave much to be desired.

  14. Full-switching FSF-type superconducting spin-triplet magnetic random access memory element

    NASA Astrophysics Data System (ADS)

    Lenk, D.; Morari, R.; Zdravkov, V. I.; Ullrich, A.; Khaydukov, Yu.; Obermeier, G.; Müller, C.; Sidorenko, A. S.; von Nidda, H.-A. Krug; Horn, S.; Tagirov, L. R.; Tidecks, R.

    2017-11-01

    In the present work a superconducting Co/CoOx/Cu41Ni59 /Nb/Cu41Ni59 nanoscale thin film heterostructure is investigated, which exhibits a superconducting transition temperature, Tc, depending on the history of magnetic field applied parallel to the film plane. In more detail, around zero applied field, Tc is lower when the field is changed from negative to positive polarity (with respect to the cooling field), compared to the opposite case. We interpret this finding as the result of the generation of the odd-in-frequency triplet component of superconductivity arising at noncollinear orientation of the magnetizations in the Cu41Ni59 layer adjacent to the CoOx layer. This interpretation is supported by superconducting quantum interference device magnetometry, which revealed a correlation between details of the magnetic structure and the observed superconducting spin-valve effects. Readout of information is possible at zero applied field and, thus, no permanent field is required to stabilize both states. Consequently, this system represents a superconducting magnetic random access memory element for superconducting electronics. By applying increased transport currents, the system can be driven to the full switching mode between the completely superconducting and the normal state.

  15. Breaking the current density threshold in spin-orbit-torque magnetic random access memory

    NASA Astrophysics Data System (ADS)

    Zhang, Yin; Yuan, H. Y.; Wang, X. S.; Wang, X. R.

    2018-04-01

    Spin-orbit-torque magnetic random access memory (SOT-MRAM) is a promising technology for the next generation of data storage devices. The main bottleneck of this technology is the high reversal current density threshold. This outstanding problem is now solved by a new strategy in which the magnitude of the driven current density is fixed while the current direction varies with time. The theoretical limit of minimal reversal current density is only a fraction (the Gilbert damping coefficient) of the threshold current density of the conventional strategy. The Euler-Lagrange equation for the fastest magnetization reversal path and the optimal current pulse is derived for an arbitrary magnetic cell and arbitrary spin-orbit torque. The theoretical limit of minimal reversal current density and current density for a GHz switching rate of the new reversal strategy for CoFeB/Ta SOT-MRAMs are, respectively, of the order of 105 A/cm 2 and 106 A/cm 2 far below 107 A/cm 2 and 108 A/cm 2 in the conventional strategy. Furthermore, no external magnetic field is needed for a deterministic reversal in the new strategy.

  16. Nonvolatile random access memory

    NASA Technical Reports Server (NTRS)

    Wu, Jiin-Chuan (Inventor); Stadler, Henry L. (Inventor); Katti, Romney R. (Inventor)

    1994-01-01

    A nonvolatile magnetic random access memory can be achieved by an array of magnet-Hall effect (M-H) elements. The storage function is realized with a rectangular thin-film ferromagnetic material having an in-plane, uniaxial anisotropy and inplane bipolar remanent magnetization states. The thin-film magnetic element is magnetized by a local applied field, whose direction is used to form either a 0 or 1 state. The element remains in the 0 or 1 state until a switching field is applied to change its state. The stored information is detcted by a Hall-effect sensor which senses the fringing field from the magnetic storage element. The circuit design for addressing each cell includes transistor switches for providing a current of selected polarity to store a binary digit through a separate conductor overlying the magnetic element of the cell. To read out a stored binary digit, transistor switches are employed to provide a current through a row of Hall-effect sensors connected in series and enabling a differential voltage amplifier connected to all Hall-effect sensors of a column in series. To avoid read-out voltage errors due to shunt currents through resistive loads of the Hall-effect sensors of other cells in the same column, at least one transistor switch is provided between every pair of adjacent cells in every row which are not turned on except in the row of the selected cell.

  17. Power reduction by power gating in differential pair type spin-transfer-torque magnetic random access memories for low-power nonvolatile cache memories

    NASA Astrophysics Data System (ADS)

    Ohsawa, Takashi; Ikeda, Shoji; Hanyu, Takahiro; Ohno, Hideo; Endoh, Tetsuo

    2014-01-01

    Array operation currents in spin-transfer-torque magnetic random access memories (STT-MRAMs) that use four differential pair type magnetic tunnel junction (MTJ)-based memory cells (4T2MTJ, two 6T2MTJs and 8T2MTJ) are simulated and compared with that in SRAM. With L3 cache applications in mind, it is assumed that the memories are composed of 32 Mbyte capacity to be accessed in 64 byte in parallel. All the STT-MRAMs except for the 8T2MTJ one are designed with 32 bit fine-grained power gating scheme applied to eliminate static currents in the memory cells that are not accessed. The 8T2MTJ STT-MRAM, the cell’s design concept being not suitable for the fine-grained power gating, loads and saves 32 Mbyte data in 64 Mbyte unit per 1 Mbit sub-array in 2 × 103 cycles. It is shown that the array operation current of the 4T2MTJ STT-MRAM is 70 mA averaged in 15 ns write cycles at Vdd = 0.9 V. This is the smallest among the STT-MRAMs, about the half of the low standby power (LSTP) SRAM whose array operation current is totally dominated by the cells’ subthreshold leakage.

  18. Quantifying data retention of perpendicular spin-transfer-torque magnetic random access memory chips using an effective thermal stability factor method

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Thomas, Luc, E-mail: luc.thomas@headway.com; Jan, Guenole; Le, Son

    The thermal stability of perpendicular Spin-Transfer-Torque Magnetic Random Access Memory (STT-MRAM) devices is investigated at chip level. Experimental data are analyzed in the framework of the Néel-Brown model including distributions of the thermal stability factor Δ. We show that in the low error rate regime important for applications, the effect of distributions of Δ can be described by a single quantity, the effective thermal stability factor Δ{sub eff}, which encompasses both the median and the standard deviation of the distributions. Data retention of memory chips can be assessed accurately by measuring Δ{sub eff} as a function of device diameter andmore » temperature. We apply this method to show that 54 nm devices based on our perpendicular STT-MRAM design meet our 10 year data retention target up to 120 °C.« less

  19. Design of a magnetic-tunnel-junction-oriented nonvolatile lookup table circuit with write-operation-minimized data shifting

    NASA Astrophysics Data System (ADS)

    Suzuki, Daisuke; Hanyu, Takahiro

    2018-04-01

    A magnetic-tunnel-junction (MTJ)-oriented nonvolatile lookup table (LUT) circuit, in which a low-power data-shift function is performed by minimizing the number of write operations in MTJ devices is proposed. The permutation of the configuration memory cell for read/write access is performed as opposed to conventional direct data shifting to minimize the number of write operations, which results in significant write energy savings in the data-shift function. Moreover, the hardware cost of the proposed LUT circuit is small since the selector is shared between read access and write access. In fact, the power consumption in the data-shift function and the transistor count are reduced by 82 and 52%, respectively, compared with those in a conventional static random-access memory-based implementation using a 90 nm CMOS technology.

  20. Long-term reliable physically unclonable function based on oxide tunnel barrier breakdown on two-transistors two-magnetic-tunnel-junctions cell-based embedded spin transfer torque magnetoresistive random access memory

    NASA Astrophysics Data System (ADS)

    Takaya, Satoshi; Tanamoto, Tetsufumi; Noguchi, Hiroki; Ikegami, Kazutaka; Abe, Keiko; Fujita, Shinobu

    2017-04-01

    Among the diverse applications of spintronics, security for internet-of-things (IoT) devices is one of the most important. A physically unclonable function (PUF) with a spin device (spin transfer torque magnetoresistive random access memory, STT-MRAM) is presented. Oxide tunnel barrier breakdown is used to realize long-term stability for PUFs. A secure PUF has been confirmed by evaluating the Hamming distance of a 32-bit STT-MRAM-PUF fabricated using 65 nm CMOS technology.

  1. Carbon nanomaterials for non-volatile memories

    NASA Astrophysics Data System (ADS)

    Ahn, Ethan C.; Wong, H.-S. Philip; Pop, Eric

    2018-03-01

    Carbon can create various low-dimensional nanostructures with remarkable electronic, optical, mechanical and thermal properties. These features make carbon nanomaterials especially interesting for next-generation memory and storage devices, such as resistive random access memory, phase-change memory, spin-transfer-torque magnetic random access memory and ferroelectric random access memory. Non-volatile memories greatly benefit from the use of carbon nanomaterials in terms of bit density and energy efficiency. In this Review, we discuss sp2-hybridized carbon-based low-dimensional nanostructures, such as fullerene, carbon nanotubes and graphene, in the context of non-volatile memory devices and architectures. Applications of carbon nanomaterials as memory electrodes, interfacial engineering layers, resistive-switching media, and scalable, high-performance memory selectors are investigated. Finally, we compare the different memory technologies in terms of writing energy and time, and highlight major challenges in the manufacturing, integration and understanding of the physical mechanisms and material properties.

  2. Correlation of anomalous write error rates and ferromagnetic resonance spectrum in spin-transfer-torque-magnetic-random-access-memory devices containing in-plane free layers

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Evarts, Eric R.; Rippard, William H.; Pufall, Matthew R.

    In a small fraction of magnetic-tunnel-junction-based magnetic random-access memory devices with in-plane free layers, the write-error rates (WERs) are higher than expected on the basis of the macrospin or quasi-uniform magnetization reversal models. In devices with increased WERs, the product of effective resistance and area, tunneling magnetoresistance, and coercivity do not deviate from typical device properties. However, the field-swept, spin-torque, ferromagnetic resonance (FS-ST-FMR) spectra with an applied DC bias current deviate significantly for such devices. With a DC bias of 300 mV (producing 9.9 × 10{sup 6} A/cm{sup 2}) or greater, these anomalous devices show an increase in the fraction of the power presentmore » in FS-ST-FMR modes corresponding to higher-order excitations of the free-layer magnetization. As much as 70% of the power is contained in higher-order modes compared to ≈20% in typical devices. Additionally, a shift in the uniform-mode resonant field that is correlated with the magnitude of the WER anomaly is detected at DC biases greater than 300 mV. These differences in the anomalous devices indicate a change in the micromagnetic resonant mode structure at high applied bias.« less

  3. Spin torque switching of 20 nm magnetic tunnel junctions with perpendicular anisotropy

    NASA Astrophysics Data System (ADS)

    Gajek, M.; Nowak, J. J.; Sun, J. Z.; Trouilloud, P. L.; O'Sullivan, E. J.; Abraham, D. W.; Gaidis, M. C.; Hu, G.; Brown, S.; Zhu, Y.; Robertazzi, R. P.; Gallagher, W. J.; Worledge, D. C.

    2012-03-01

    Spin-transfer torque magnetic random access memory (STT-MRAM) is one of the most promising emerging non-volatile memory technologies. MRAM has so far been demonstrated with a unique combination of density, speed, and non-volatility in a single chip, however, without the capability to replace any single mainstream memory. In this paper, we demonstrate the basic physics of spin torque switching in 20 nm diameter magnetic tunnel junctions with perpendicular magnetic anisotropy materials. This deep scaling capability clearly indicates the STT MRAM device itself may be suitable for integration at much higher densities than previously proven.

  4. Enhanced ferromagnetic resonance linewidth of the free layer in perpendicular magnetic tunnel junctions

    NASA Astrophysics Data System (ADS)

    Gopman, D. B.; Dennis, C. L.; McMichael, R. D.; Hao, X.; Wang, Z.; Wang, X.; Gan, H.; Zhou, Y.; Zhang, J.; Huai, Y.

    2017-05-01

    We report the frequency dependence of the ferromagnetic resonance linewidth of the free layer in magnetic tunnel junctions with all perpendicular-to-the-plane magnetized layers. While the magnetic-field-swept linewidth nominally shows a linear growth with frequency in agreement with Gilbert damping, an additional frequency-dependent linewidth broadening occurs that shows a strong asymmetry between the absorption spectra for increasing and decreasing external magnetic field. Inhomogeneous magnetic fields produced during reversal of the reference and pinned layer complex is demonstrated to be at the origin of the symmetry breaking and the linewidth enhancement. Consequentially, this linewidth enhancement provides indirect information on the magnetic coercivity of the reference and pinned layers. These results have important implications for the characterization of perpendicular magnetized magnetic random access memory bit cells.

  5. Magnetic domain wall engineering in a nanoscale permalloy junction

    NASA Astrophysics Data System (ADS)

    Wang, Junlin; Zhang, Xichao; Lu, Xianyang; Zhang, Jason; Yan, Yu; Ling, Hua; Wu, Jing; Zhou, Yan; Xu, Yongbing

    2017-08-01

    Nanoscale magnetic junctions provide a useful approach to act as building blocks for magnetoresistive random access memories (MRAM), where one of the key issues is to control the magnetic domain configuration. Here, we study the domain structure and the magnetic switching in the Permalloy (Fe20Ni80) nanoscale magnetic junctions with different thicknesses by using micromagnetic simulations. It is found that both the 90-° and 45-° domain walls can be formed between the junctions and the wire arms depending on the thickness of the device. The magnetic switching fields show distinct thickness dependencies with a broad peak varying from 7 nm to 22 nm depending on the junction sizes, and the large magnetic switching fields favor the stability of the MRAM operation.

  6. Magnetic field dependence of spin torque switching in nanoscale magnetic tunnel junctions

    NASA Astrophysics Data System (ADS)

    Yang, Liu; Rowlands, Graham; Katine, Jordan; Langer, Juergen; Krivorotov, Ilya

    2012-02-01

    Magnetic random access memory based on spin transfer torque effect in nanoscale magnetic tunnel junctions (STT-RAM) is emerging as a promising candidate for embedded and stand-alone computer memory. An important performance parameter of STT-RAM is stability of its free magnetic layer against thermal fluctuations. Measurements of the free layer switching probability as a function of sub-critical voltage at zero effective magnetic field (read disturb rate or RDR measurements) have been proposed as a method for quantitative evaluation of the free layer thermal stability at zero voltage. In this presentation, we report RDR measurement as a function of external magnetic field, which provide a test of the RDR method self-consistency and reliability.

  7. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Kan, Jimmy J.; Gottwald, Matthias; Fullerton, Eric E.

    We describe low-temperature characterization of magnetic tunnel junctions (MTJs) patterned by reactive ion etching for spin-transfer-torque magnetic random access memory. Magnetotransport measurements of typical MTJs show increasing tunneling magnetoresistance (TMR) and larger coercive fields as temperature is decreased down to 10 K. However, MTJs selected from the high-resistance population of an MTJ array exhibit stable intermediate magnetic states when measured at low temperature and show TMR roll-off below 100 K. These non-ideal low-temperature behaviors arise from edge damage during the etch process and can have negative impacts on thermal stability of the MTJs.

  8. Towards developing a compact model for magnetization switching in straintronics magnetic random access memory devices

    NASA Astrophysics Data System (ADS)

    Barangi, Mahmood; Erementchouk, Mikhail; Mazumder, Pinaki

    2016-08-01

    Strain-mediated magnetization switching in a magnetic tunneling junction (MTJ) by exploiting a combination of piezoelectricity and magnetostriction has been proposed as an energy efficient alternative to spin transfer torque (STT) and field induced magnetization switching methods in MTJ-based magnetic random access memories (MRAM). Theoretical studies have shown the inherent advantages of strain-assisted switching, and the dynamic response of the magnetization has been modeled using the Landau-Lifshitz-Gilbert (LLG) equation. However, an attempt to use LLG for simulating dynamics of individual elements in large-scale simulations of multi-megabyte straintronics MRAM leads to extremely time-consuming calculations. Hence, a compact analytical solution, predicting the flipping delay of the magnetization vector in the nanomagnet under stress, combined with a liberal approximation of the LLG dynamics in the straintronics MTJ, can lead to a simplified model of the device suited for fast large-scale simulations of multi-megabyte straintronics MRAMs. In this work, a tensor-based approach is developed to study the dynamic behavior of the stressed nanomagnet. First, using the developed method, the effect of stress on the switching behavior of the magnetization is investigated to realize the margins between the underdamped and overdamped regimes. The latter helps the designer realize the oscillatory behavior of the magnetization when settling along the minor axis, and the dependency of oscillations on the stress level and the damping factor. Next, a theoretical model to predict the flipping delay of the magnetization vector is developed and tested against LLG-based numerical simulations to confirm the accuracy of findings. Lastly, the obtained delay is incorporated into the approximate solutions of the LLG dynamics, in order to create a compact model to liberally and quickly simulate the magnetization dynamics of the MTJ under stress. Using the developed delay equation, the efficiency of the straintronics switching over the STT method is highlighted by analytically investigating the energy-delay trade-off of both methodologies.

  9. Towards developing a compact model for magnetization switching in straintronics magnetic random access memory devices

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Barangi, Mahmood, E-mail: barangi@umich.edu; Erementchouk, Mikhail; Mazumder, Pinaki

    Strain-mediated magnetization switching in a magnetic tunneling junction (MTJ) by exploiting a combination of piezoelectricity and magnetostriction has been proposed as an energy efficient alternative to spin transfer torque (STT) and field induced magnetization switching methods in MTJ-based magnetic random access memories (MRAM). Theoretical studies have shown the inherent advantages of strain-assisted switching, and the dynamic response of the magnetization has been modeled using the Landau-Lifshitz-Gilbert (LLG) equation. However, an attempt to use LLG for simulating dynamics of individual elements in large-scale simulations of multi-megabyte straintronics MRAM leads to extremely time-consuming calculations. Hence, a compact analytical solution, predicting the flippingmore » delay of the magnetization vector in the nanomagnet under stress, combined with a liberal approximation of the LLG dynamics in the straintronics MTJ, can lead to a simplified model of the device suited for fast large-scale simulations of multi-megabyte straintronics MRAMs. In this work, a tensor-based approach is developed to study the dynamic behavior of the stressed nanomagnet. First, using the developed method, the effect of stress on the switching behavior of the magnetization is investigated to realize the margins between the underdamped and overdamped regimes. The latter helps the designer realize the oscillatory behavior of the magnetization when settling along the minor axis, and the dependency of oscillations on the stress level and the damping factor. Next, a theoretical model to predict the flipping delay of the magnetization vector is developed and tested against LLG-based numerical simulations to confirm the accuracy of findings. Lastly, the obtained delay is incorporated into the approximate solutions of the LLG dynamics, in order to create a compact model to liberally and quickly simulate the magnetization dynamics of the MTJ under stress. Using the developed delay equation, the efficiency of the straintronics switching over the STT method is highlighted by analytically investigating the energy-delay trade-off of both methodologies.« less

  10. Geophysical data base

    NASA Technical Reports Server (NTRS)

    Williamson, M. R.; Kirschner, L. R.

    1975-01-01

    A general data-management system that provides a random-access capability for large amounts of data is described. The system operates on a CDC 6400 computer using a combination of magnetic tape and disk storage. A FORTRAN subroutine package is provided to simplify the maintenance and use of the data.

  11. Magnetic Thin Films for Perpendicular Magnetic Recording Systems

    NASA Astrophysics Data System (ADS)

    Sugiyama, Atsushi; Hachisu, Takuma; Osaka, Tetsuya

    In the advanced information society of today, information storage technology, which helps to store a mass of electronic data and offers high-speed random access to the data, is indispensable. Against this background, hard disk drives (HDD), which are magnetic recording devices, have gained in importance because of their advantages in capacity, speed, reliability, and production cost. These days, the uses of HDD extend not only to personal computers and network servers but also to consumer electronics products such as personal video recorders, portable music players, car navigation systems, video games, video cameras, and personal digital assistances.

  12. Influence of cooling rate in planar thermally assisted magnetic random access memory: Improved writeability due to spin-transfer-torque influence

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Chavent, A.; CNRS, INAC-SPINTEC, F-38000 Grenoble; CEA, INAC-SPINTEC, F-38000 Grenoble

    This paper investigates the effect of a controlled cooling rate on magnetic field reversal assisted by spin transfer torque (STT) in thermally assisted magnetic random access memory. By using a gradual linear decrease of the voltage at the end of the write pulse, the STT decays more slowly or at least at the same rate as the temperature. This condition is necessary to make sure that the storage layer magnetization remains in the desired written direction during cooling of the cell. The influence of the write current pulse decay rate was investigated on two exchange biased synthetic ferrimagnet (SyF) electrodes.more » For a NiFe based electrode, a significant improvement in writing reproducibility was observed using a gradual linear voltage transition. The write error rate decreases by a factor of 10 when increasing the write pulse fall-time from ∼3 ns to 70 ns. For comparison, a second CoFe/NiFe based electrode was also reversed by magnetic field assisted by STT. In this case, no difference between sharp and linear write pulse fall shape was observed. We attribute this observation to the higher thermal stability of the CoFe/NiFe electrode during cooling. In real-time measurements of the magnetization reversal, it was found that Ruderman-Kittel-Kasuya-Yosida (RKKY) coupling in the SyF electrode vanishes for the highest pulse voltages that were used due to the high temperature reached during write. As a result, during the cooling phase, the final state is reached through a spin-flop transition of the SyF storage layer.« less

  13. Exploration of perpendicular magnetic anisotropy material system for application in spin transfer torque - Random access memory

    NASA Astrophysics Data System (ADS)

    Natarajarathinam, Anusha

    Perpendicular magnetic anisotropy (PMA) materials have unique advantages when used in magnetic tunnel junctions (MTJ) which are the most critical part of spin-torque transfer random access memory devices (STT-RAMs) that are being researched intensively as future non-volatile memory technology. They have high magnetoresistance which improves their sensitivity. The STT-RAM has several advantages over competing technologies, for instance, low power consumption, non-volatility, ultra-fast read and write speed and high endurance. In personal computers, it can replace SRAM for high-speed applications, Flash for non-volatility, and PSRAM and DRAM for high-speed program execution. The main aim of this research is to identify and optimize the best perpendicular magnetic anisotropy (PMA) material system for application to STT-RAM technology. Preliminary search for perpendicular magnetic anisotropy (PMA) materials for pinned layer for MTJs started with the exploration and optimization of crystalline alloys such as Co50Pd50 alloy, Mn50Al50 and amorphous alloys such as Tb21Fe72Co7 and are first presented in this work. Further optimization includes the study of Co/[Pd/Pt]x multilayers (ML), and the development of perpendicular synthetic antiferromagnets (SAF) utilizing these multilayers. Focused work on capping and seed layers to evaluate interfacial perpendicular anisotropy in free layers for pMTJs is then discussed. Optimization of the full perpendicular magnetic tunnel junction (pMTJ) includes the CoFeB/MgO/CoFeB trilayer coupled to a pinned/pinning layer with perpendicular Co/[Pd/Pt]x SAF and a thin Ta seeded CoFeB free layer. Magnetometry, simulations, annealing studies, transport measurements and TEM analysis on these samples will then be presented.

  14. Thin Co/Ni-based bottom pinned spin-transfer torque magnetic random access memory stacks with high annealing tolerance

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Tomczak, Y., E-mail: Yoann.Tomczak@imec.be; Department of Chemistry, KU Leuven; Swerts, J.

    2016-01-25

    Spin-transfer torque magnetic random access memory (STT-MRAM) is considered as a replacement for next generation embedded and stand-alone memory applications. One of the main challenges in the STT-MRAM stack development is the compatibility of the stack with CMOS process flows in which thermal budgets up to 400 °C are applied. In this letter, we report on a perpendicularly magnetized MgO-based tunnel junction (p-MTJ) on a thin Co/Ni perpendicular synthetic antiferromagnetic layer with high annealing tolerance. Tunnel magneto resistance (TMR) loss after annealing occurs when the reference layer loses its perpendicular magnetic anisotropy due to reduction of the CoFeB/MgO interfacial anisotropy. Amore » stable Co/Ni based p-MTJ stack with TMR values of 130% at resistance-area products of 9 Ω μm{sup 2} after 400 °C anneal is achieved via moment control of the Co/Ta/CoFeB reference layer. Thinning of the CoFeB polarizing layer down to 0.8 nm is the key enabler to achieve 400 °C compatibility with limited TMR loss. Thinning the Co below 0.6 nm leads to a loss of the antiferromagnetic interlayer exchange coupling strength through Ru. Insight into the thickness and moment engineering of the reference layer is displayed to obtain the best magnetic properties and high thermal stability for thin Co/Ni SAF-based STT-MRAM stacks.« less

  15. Soft-error tolerance and energy consumption evaluation of embedded computer with magnetic random access memory in practical systems using computer simulations

    NASA Astrophysics Data System (ADS)

    Nebashi, Ryusuke; Sakimura, Noboru; Sugibayashi, Tadahiko

    2017-08-01

    We evaluated the soft-error tolerance and energy consumption of an embedded computer with magnetic random access memory (MRAM) using two computer simulators. One is a central processing unit (CPU) simulator of a typical embedded computer system. We simulated the radiation-induced single-event-upset (SEU) probability in a spin-transfer-torque MRAM cell and also the failure rate of a typical embedded computer due to its main memory SEU error. The other is a delay tolerant network (DTN) system simulator. It simulates the power dissipation of wireless sensor network nodes of the system using a revised CPU simulator and a network simulator. We demonstrated that the SEU effect on the embedded computer with 1 Gbit MRAM-based working memory is less than 1 failure in time (FIT). We also demonstrated that the energy consumption of the DTN sensor node with MRAM-based working memory can be reduced to 1/11. These results indicate that MRAM-based working memory enhances the disaster tolerance of embedded computers.

  16. IMAGINE: Interstellar MAGnetic field INference Engine

    NASA Astrophysics Data System (ADS)

    Steininger, Theo

    2018-03-01

    IMAGINE (Interstellar MAGnetic field INference Engine) performs inference on generic parametric models of the Galaxy. The modular open source framework uses highly optimized tools and technology such as the MultiNest sampler (ascl:1109.006) and the information field theory framework NIFTy (ascl:1302.013) to create an instance of the Milky Way based on a set of parameters for physical observables, using Bayesian statistics to judge the mismatch between measured data and model prediction. The flexibility of the IMAGINE framework allows for simple refitting for newly available data sets and makes state-of-the-art Bayesian methods easily accessible particularly for random components of the Galactic magnetic field.

  17. Overview of emerging nonvolatile memory technologies

    PubMed Central

    2014-01-01

    Nonvolatile memory technologies in Si-based electronics date back to the 1990s. Ferroelectric field-effect transistor (FeFET) was one of the most promising devices replacing the conventional Flash memory facing physical scaling limitations at those times. A variant of charge storage memory referred to as Flash memory is widely used in consumer electronic products such as cell phones and music players while NAND Flash-based solid-state disks (SSDs) are increasingly displacing hard disk drives as the primary storage device in laptops, desktops, and even data centers. The integration limit of Flash memories is approaching, and many new types of memory to replace conventional Flash memories have been proposed. Emerging memory technologies promise new memories to store more data at less cost than the expensive-to-build silicon chips used by popular consumer gadgets including digital cameras, cell phones and portable music players. They are being investigated and lead to the future as potential alternatives to existing memories in future computing systems. Emerging nonvolatile memory technologies such as magnetic random-access memory (MRAM), spin-transfer torque random-access memory (STT-RAM), ferroelectric random-access memory (FeRAM), phase-change memory (PCM), and resistive random-access memory (RRAM) combine the speed of static random-access memory (SRAM), the density of dynamic random-access memory (DRAM), and the nonvolatility of Flash memory and so become very attractive as another possibility for future memory hierarchies. Many other new classes of emerging memory technologies such as transparent and plastic, three-dimensional (3-D), and quantum dot memory technologies have also gained tremendous popularity in recent years. Subsequently, not an exaggeration to say that computer memory could soon earn the ultimate commercial validation for commercial scale-up and production the cheap plastic knockoff. Therefore, this review is devoted to the rapidly developing new class of memory technologies and scaling of scientific procedures based on an investigation of recent progress in advanced Flash memory devices. PMID:25278820

  18. Overview of emerging nonvolatile memory technologies.

    PubMed

    Meena, Jagan Singh; Sze, Simon Min; Chand, Umesh; Tseng, Tseung-Yuen

    2014-01-01

    Nonvolatile memory technologies in Si-based electronics date back to the 1990s. Ferroelectric field-effect transistor (FeFET) was one of the most promising devices replacing the conventional Flash memory facing physical scaling limitations at those times. A variant of charge storage memory referred to as Flash memory is widely used in consumer electronic products such as cell phones and music players while NAND Flash-based solid-state disks (SSDs) are increasingly displacing hard disk drives as the primary storage device in laptops, desktops, and even data centers. The integration limit of Flash memories is approaching, and many new types of memory to replace conventional Flash memories have been proposed. Emerging memory technologies promise new memories to store more data at less cost than the expensive-to-build silicon chips used by popular consumer gadgets including digital cameras, cell phones and portable music players. They are being investigated and lead to the future as potential alternatives to existing memories in future computing systems. Emerging nonvolatile memory technologies such as magnetic random-access memory (MRAM), spin-transfer torque random-access memory (STT-RAM), ferroelectric random-access memory (FeRAM), phase-change memory (PCM), and resistive random-access memory (RRAM) combine the speed of static random-access memory (SRAM), the density of dynamic random-access memory (DRAM), and the nonvolatility of Flash memory and so become very attractive as another possibility for future memory hierarchies. Many other new classes of emerging memory technologies such as transparent and plastic, three-dimensional (3-D), and quantum dot memory technologies have also gained tremendous popularity in recent years. Subsequently, not an exaggeration to say that computer memory could soon earn the ultimate commercial validation for commercial scale-up and production the cheap plastic knockoff. Therefore, this review is devoted to the rapidly developing new class of memory technologies and scaling of scientific procedures based on an investigation of recent progress in advanced Flash memory devices.

  19. Spin-orbit torque induced magnetic vortex polarity reversal utilizing spin-Hall effect

    NASA Astrophysics Data System (ADS)

    Li, Cheng; Cai, Li; Liu, Baojun; Yang, Xiaokuo; Cui, Huanqing; Wang, Sen; Wei, Bo

    2018-05-01

    We propose an effective magnetic vortex polarity reversal scheme that makes use of spin-orbit torque introduced by spin-Hall effect in heavy-metal/ferromagnet multilayers structure, which can result in subnanosecond polarity reversal without endangering the structural stability. Micromagnetic simulations are performed to investigate the spin-Hall effect driven dynamics evolution of magnetic vortex. The mechanism of magnetic vortex polarity reversal is uncovered by a quantitative analysis of exchange energy density, magnetostatic energy density, and their total energy density. The simulation results indicate that the magnetic vortex polarity is reversed through the nucleation-annihilation process of topological vortex-antivortex pair. This scheme is an attractive option for ultra-fast magnetic vortex polarity reversal, which can be used as the guidelines for the choice of polarity reversal scheme in vortex-based random access memory.

  20. Magnetization switching in ferromagnets by adsorbed chiral molecules without current or external magnetic field.

    PubMed

    Ben Dor, Oren; Yochelis, Shira; Radko, Anna; Vankayala, Kiran; Capua, Eyal; Capua, Amir; Yang, See-Hun; Baczewski, Lech Tomasz; Parkin, Stuart Stephen Papworth; Naaman, Ron; Paltiel, Yossi

    2017-02-23

    Ferromagnets are commonly magnetized by either external magnetic fields or spin polarized currents. The manipulation of magnetization by spin-current occurs through the spin-transfer-torque effect, which is applied, for example, in modern magnetoresistive random access memory. However, the current density required for the spin-transfer torque is of the order of 1 × 10 6  A·cm -2 , or about 1 × 10 25 electrons s -1 cm -2 . This relatively high current density significantly affects the devices' structure and performance. Here we demonstrate magnetization switching of ferromagnetic thin layers that is induced solely by adsorption of chiral molecules. In this case, about 10 13 electrons per cm 2 are sufficient to induce magnetization reversal. The direction of the magnetization depends on the handedness of the adsorbed chiral molecules. Local magnetization switching is achieved by adsorbing a chiral self-assembled molecular monolayer on a gold-coated ferromagnetic layer with perpendicular magnetic anisotropy. These results present a simple low-power magnetization mechanism when operating at ambient conditions.

  1. Magnetization switching in ferromagnets by adsorbed chiral molecules without current or external magnetic field

    PubMed Central

    Ben Dor, Oren; Yochelis, Shira; Radko, Anna; Vankayala, Kiran; Capua, Eyal; Capua, Amir; Yang, See-Hun; Baczewski, Lech Tomasz; Parkin, Stuart Stephen Papworth; Naaman, Ron; Paltiel, Yossi

    2017-01-01

    Ferromagnets are commonly magnetized by either external magnetic fields or spin polarized currents. The manipulation of magnetization by spin-current occurs through the spin-transfer-torque effect, which is applied, for example, in modern magnetoresistive random access memory. However, the current density required for the spin-transfer torque is of the order of 1 × 106 A·cm−2, or about 1 × 1025 electrons s−1 cm−2. This relatively high current density significantly affects the devices' structure and performance. Here we demonstrate magnetization switching of ferromagnetic thin layers that is induced solely by adsorption of chiral molecules. In this case, about 1013 electrons per cm2 are sufficient to induce magnetization reversal. The direction of the magnetization depends on the handedness of the adsorbed chiral molecules. Local magnetization switching is achieved by adsorbing a chiral self-assembled molecular monolayer on a gold-coated ferromagnetic layer with perpendicular magnetic anisotropy. These results present a simple low-power magnetization mechanism when operating at ambient conditions. PMID:28230054

  2. Micromagnetic modeling of the shielding properties of nanoscale ferromagnetic layers

    NASA Astrophysics Data System (ADS)

    Iskandarova, I. M.; Knizhnik, A. A.; Popkov, A. F.; Potapkin, B. V.; Stainer, Q.; Lombard, L.; Mackay, K.

    2016-09-01

    Ferromagnetic shields are widely used to concentrate magnetic fields in a target region of space. Such shields are also used in spintronic nanodevices such as magnetic random access memory and magnetic logic devices. However, the shielding properties of nanostructured shields can differ considerably from those of macroscopic samples. In this work, we investigate the shielding properties of nanostructured NiFe layers around a current line using a finite element micromagnetic model. We find that thin ferromagnetic layers demonstrate saturation of magnetization under an external magnetic field, which reduces the shielding efficiency. Moreover, we show that the shielding properties of nanoscale ferromagnetic layers strongly depend on the uniformity of the layer thickness. Magnetic anisotropy in ultrathin ferromagnetic layers can also influence their shielding efficiency. In addition, we show that domain walls in nanoscale ferromagnetic shields can induce large increases and decreases in the generated magnetic field. Therefore, ferromagnetic shields for spintronic nanodevices require careful design and precise fabrication.

  3. Reversal of spontaneous magnetization and spontaneous exchange bias for Sm1-xYxCrO3: The effect of Y doping

    NASA Astrophysics Data System (ADS)

    Zhang, Hongguang; Wang, Jianhua; Xie, Liang; Fu, Dexiang; Guo, Yanyan; Li, Yongtao

    2017-11-01

    We report the crystal and electronic structures and magnetic properties of non-magnetic Y3+ ion doped SmCrO3 crystals. Structural distortion and electronic structure variation are caused by cation disorder due to Y doping. Although the spin moment of Sm3+ is diluted by nonmagnetic Y ions, spin reorientation continues to exist, and the temperature-dependent magnetization reversal effect and the spontaneous exchange bias effect under zero field cooling are simultaneously induced below Neel temperature. Significantly, the method of doping promotes the achievement of temperature dependent tunable switching of magnetization and sign of a spontaneous exchange bias from positive to negative. Our work provides more tunable ways to the sign reversal of magnetization and exchange bias, which have potential application in designing magnetic random access memory devices, thermomagnetic switches and spin-valve devices.

  4. Modulation of spin transfer torque amplitude in double barrier magnetic tunnel junctions

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Clément, P.-Y.; Baraduc, C., E-mail: claire.baraduc@cea.fr; Chshiev, M.

    2015-09-07

    Magnetization switching induced by spin transfer torque is used to write magnetic memories (Magnetic Random Access Memory, MRAM) but can be detrimental to the reading process. It would be quite convenient therefore to modulate the efficiency of spin transfer torque. A solution is adding an extra degree of freedom by using double barrier magnetic tunnel junctions with two spin-polarizers, with controllable relative magnetic alignment. We demonstrate, for these structures, that the amplitude of in-plane spin transfer torque on the middle free layer can be efficiently tuned via the magnetic configuration of the electrodes. Using the proposed design could thus pavemore » the way towards more reliable read/write schemes for MRAM. Moreover, our results suggest an intriguing effect associated with the out-of-plane (field-like) spin transfer torque, which has to be further investigated.« less

  5. Analysis of self-heating of thermally assisted spin-transfer torque magnetic random access memory

    DOE PAGES

    Deschenes, Austin; Muneer, Sadid; Akbulut, Mustafa; ...

    2016-11-11

    Thermal assistance has been shown to significantly reduce the required operation power for spin torque transfer magnetic random access memory (STT-MRAM). Proposed heating methods include modified material stack compositions that result in increased self-heating or external heat sources. Here, we analyze the self-heating process of a standard perpendicular magnetic anisotropy STT-MRAM device through numerical simulations in order to understand the relative contributions of Joule, thermoelectric Peltier and Thomson, and tunneling junction heating. A 2D rotationally symmetric numerical model is used to solve the coupled electro-thermal equations including thermoelectric effects and heat absorbed or released at the tunneling junction. We comparemore » self-heating for different common passivation materials, positive and negative electrical current polarity, and different device thermal anchoring and boundaries resistance configurations. The variations considered are found to result in significant differences in maximum temperatures reached. Average increases of 3 K, 10 K, and 100 K for different passivation materials, positive and negative polarity, and different thermal anchoring configurations, respectively, are observed. Furthermore, the highest temperatures, up to 424 K, are obtained for silicon dioxide as the passivation material, positive polarity, and low thermal anchoring with thermal boundary resistance configurations. Interestingly it is also found that due to the tunneling heat, Peltier effect, device geometry, and numerous interfacial layers around the magnetic tunnel junction (MTJ), most of the heat is dissipated on the lower potential side of the magnetic junction. We have observed this asymmetry in heating and is important as thermally assisted switching requires heating of the free layer specifically and this will be significantly different for the two polarity operations, set and reset.« less

  6. Software for Optical Archive and Retrieval (SOAR) user's guide, version 4.2

    NASA Technical Reports Server (NTRS)

    Davis, Charles

    1991-01-01

    The optical disk is an emerging technology. Because it is not a magnetic medium, it offers a number of distinct advantages over the established form of storage, advantages that make it extremely attractive. They are as follows: (1) the ability to store much more data within the same space; (2) the random access characteristics of the Write Once Read Many optical disk; (3) a much longer life than that of traditional storage media; and (4) much greater data access rate. Software for Optical Archive and Retrieval (SOAR) user's guide is presented.

  7. Structural phase transitions in isotropic magnetic elastomers

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Meilikhov, E. Z., E-mail: meilikhov@yandex.ru; Farzetdinova, R. M.

    Magnetic elastomers represent a new type of materials that are “soft” matrices with “hard” magnetic granules embedded in them. The elastic forces of the matrix and the magnetic forces acting between granules are comparable in magnitude even under small deformations. As a result, these materials acquire a number of new properties; in particular, their mechanical and/or magnetic characteristics can depend strongly on the polymer matrix filling with magnetic particles and can change under the action of an external magnetic field, pressure, and temperature. To describe the properties of elastomers, we use a model in which the interaction of magnetic granulesmore » randomly arranged in space with one another is described in the dipole approximation by the distribution function of dipole fields, while their interaction with the matrix is described phenomenologically. A multitude of deformation, magnetic-field, and temperature effects that are described in this paper and are quite accessible to experimental observation arise within this model.« less

  8. Strain-driven electric control of magnetization reversal at multiferroic interfaces

    NASA Astrophysics Data System (ADS)

    Odkhuu, Dorj; Kioussis, Nicholas

    2018-03-01

    We predict that biaxial strain of several percent has a colossal effect on the magnetic anisotropy of ultrathin Fe /X TiO3 (X =Sr ,Ba ) bilayers grown epitaxially on appropriate substrates. We demonstrate that under large compressive biaxial strain the Fe film undergoes an in-plane to out-of-plane spin reorientation via ferroelectric polarization switching, where the critical strain depends on the Fe film thickness. The underlying mechanism is the interplay between the strain-enhanced magnetoelectric coupling associated with the enhanced polarization in the ferroelectric substrate and the strain-reduced magnetic anisotropy energy of the Fe overlayer. These findings open interesting prospects for exploiting stain engineering to harvest higher electric field efficiency of magnetic anisotropy for the next generation of magnetoelectric random access memory devices.

  9. Stress-based control of magnetic nanowire domain walls in artificial multiferroic systems

    NASA Astrophysics Data System (ADS)

    Dean, J.; Bryan, M. T.; Schrefl, T.; Allwood, D. A.

    2011-01-01

    Artificial multiferroic systems, which combine piezoelectric and piezomagnetic materials, offer novel methods of controlling material properties. Here, we use combined structural and magnetic finite element models to show how localized strains in a piezoelectric film coupled to a piezomagnetic nanowire can attract and pin magnetic domain walls. Synchronous switching of addressable contacts enables the controlled movement of pinning sites, and hence domain walls, in the nanowire without applied magnetic field or spin-polarized current, irrespective of domain wall structure. Conversely, domain wall-induced strain in the piezomagnetic material induces a local potential difference in the piezoelectric, providing a mechanism for sensing domain walls. This approach overcomes the problems in magnetic nanowire memories of domain wall structure-dependent behavior and high power consumption. Nonvolatile random access or shift register memories based on these effects can achieve storage densities >1 Gbit/In2, sub-10 ns switching times, and power consumption <100 keV per operation.

  10. The need for control of magnetic parameters for energy efficient performance of magnetic tunnel junctions

    NASA Astrophysics Data System (ADS)

    Farhat, I. A. H.; Gale, E.; Alpha, C.; Isakovic, A. F.

    2017-07-01

    Optimizing energy performance of Magnetic Tunnel Junctions (MTJs) is the key for embedding Spin Transfer Torque-Random Access Memory (STT-RAM) in low power circuits. Due to the complex interdependencies of the parameters and variables of the device operating energy, it is important to analyse parameters with most effective control of MTJ power. The impact of threshold current density, Jco , on the energy and the impact of HK on Jco are studied analytically, following the expressions that stem from Landau-Lifshitz-Gilbert-Slonczewski (LLGS-STT) model. In addition, the impact of other magnetic material parameters, such as Ms , and geometric parameters such as tfree and λ is discussed. Device modelling study was conducted to analyse the impact at the circuit level. Nano-magnetism simulation based on NMAGTM package was conducted to analyse the impact of controlling HK on the switching dynamics of the film.

  11. Giant magnetoresistance in perpendicularly magnetized synthetic antiferromagnetic coupling with Ir spacer

    NASA Astrophysics Data System (ADS)

    Fukushima, A.; Taniguchi, T.; Sugihara, A.; Yakushiji, K.; Kubota, H.; Yuasa, S.

    2018-05-01

    Perpendicularly magnetized magnetic tunnel junction (p-MTJ) is a key element for developing high-density spin-transfer torque switching magnetoresistive random access memory. Recently, a large exchange coupling (IEC) in the synthetic antiferromagnetic reference layer with Ir interlayer was observed in p-MTJs. The evaluation of the IEC is, however, difficult due to the electrostatic breakdown of MTJs. This study demonstrates the evaluation of the IEC with Ir interlayer in giant magnetoresistive (GMR) nanopillar. We fabricated three kinds of perpendicularly magnetized GMR elements; bottom-free structures with Cu or Ir spacer, and top-free structure with Ir spacer. The magnetoresistance (RH) loops of all samples show sharp changes of the magnetoresistance at the magnetic fields over ±10 kOe, indicating the existence of the large IECs. In particular, a sharp change of the magnetoresistance at the field over ±20 kOe was found for the element with Cu of 2 nm thickness.

  12. Effect of rare earth metal on the spin-orbit torque in magnetic heterostructures

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Ueda, Kohei; Pai, Chi-Feng; Tan, Aik Jun

    2016-06-06

    We report the effect of the rare earth metal Gd on current-induced spin-orbit torques (SOTs) in perpendicularly magnetized Pt/Co/Gd heterostructures, characterized using harmonic measurements and spin-torque ferromagnetic resonance (ST-FMR). By varying the Gd metal layer thickness from 0 nm to 8 nm, harmonic measurements reveal a significant enhancement of the effective fields generated from the Slonczewski-like and field-like torques. ST-FMR measurements confirm an enhanced effective spin Hall angle and show a corresponding increase in the magnetic damping constant with increasing Gd thickness. These results suggest that Gd plays an active role in generating SOTs in these heterostructures. Our finding may lead tomore » spin-orbitronics device application such as non-volatile magnetic random access memory, based on rare earth metals.« less

  13. LLB simulation of the temperature dependent switching critical curve of a Stoner-Wohlfarth macrospin in the presence of a polarized current

    NASA Astrophysics Data System (ADS)

    Oniciuc, E.; Stoleriu, L.; Stancu, A.

    2014-02-01

    An extension of Landau-Lifshitz-Bloch (LLB) equation is used to describe the behavior of single-domain particles under the influence of magnetic fields and polarized currents at elevated temperatures. We prove that using such a model, which takes into account the longitudinal magnetization relaxation, together with the consideration of the quartic crystalline anisotropy term, a number of recent experimental results can be explained concerning the free layer characteristic critical curves of spin valves commonly used in spin electronics. These results are of paramount importance for heat assisted magnetic recording (HAMR) processes in hard-drives or in new memory systems like the spin-transfer-torque magnetic random access memory (HA-STTMRAM) with the aim of increasing data density writing while avoiding superparamagnetic limit.

  14. Large magnetoresistance and sharp switching in FexTiS2

    NASA Astrophysics Data System (ADS)

    Choe, Jesse; Morosan, Emilia

    Large magnetoresistance materials are suitable for applications in sensors, read heads, and random access memories. Most metals, though having excellent ductility which is important for manufacturing processes, have changes of magnetoresistance on the order of only 1 % . Very large magnetoresistances in Fe0.30TaS2 ( 140 %) have been attributed to misalignment of magnetic moments causing spin disorder scattering. We performed measurements of the magnetic field dependence of resistivity and magnetization of FexTiS2 single crystals (x = 0 . 1 - 0 . 5), which show both the large magnetoresistance, as well as the sharp switching in magnetization as those reported in the Ta analogue. By comparing and contrasting these two materials, we can gain deeper understanding of the underlying physics, allowing us to strategically search for materials with higher transition temperature, lower switching fields, and larger magnetoresistances. NSF DMREF 1629374.

  15. Spin-orbit torque induced magnetization switching in Ta/Co{sub 20}Fe{sub 60}B{sub 20}/MgO structures under small in-plane magnetic fields

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Cao, Jiangwei, E-mail: caojw@lzu.edu.cn; Zheng, Yuqiang; Su, Xianpeng

    2016-04-25

    Spin-orbit torque (SOT)-induced magnetization switching under small in-plane magnetic fields in as-deposited and annealed Ta/CoFeB/MgO structures is studied. For the as-deposited samples, partial SOT-induced switching behavior is observed under an in-plane field of less than 100 Oe. Conversely, for the annealed samples, an in-plane field of 10 Oe is large enough to achieve full deterministic magnetization switching. The Dzyaloshinskii-Moriya interaction at the Ta/CoFeB interface is believed to be the main reason for the discrepancy of the requisite in-plane magnetic fields for switching in the as-deposited and annealed samples. In addition, asymmetric field dependence behavior of SOT-induced magnetization switching is observed in themore » annealed samples. Deterministic magnetization switching in the absence of an external magnetic field is obtained in the annealed samples, which is extremely important to develop SOT-based magnetoresistive random access memory.« less

  16. Non-Volatile Ferroelectric Switching of Ferromagnetic Resonance in NiFe/PLZT Multiferroic Thin Film Heterostructures.

    PubMed

    Hu, Zhongqiang; Wang, Xinjun; Nan, Tianxiang; Zhou, Ziyao; Ma, Beihai; Chen, Xiaoqin; Jones, John G; Howe, Brandon M; Brown, Gail J; Gao, Yuan; Lin, Hwaider; Wang, Zhiguang; Guo, Rongdi; Chen, Shuiyuan; Shi, Xiaoling; Shi, Wei; Sun, Hongzhi; Budil, David; Liu, Ming; Sun, Nian X

    2016-09-01

    Magnetoelectric effect, arising from the interfacial coupling between magnetic and electrical order parameters, has recently emerged as a robust means to electrically manipulate the magnetic properties in multiferroic heterostructures. Challenge remains as finding an energy efficient way to modify the distinct magnetic states in a reliable, reversible, and non-volatile manner. Here we report ferroelectric switching of ferromagnetic resonance in multiferroic bilayers consisting of ultrathin ferromagnetic NiFe and ferroelectric Pb0.92La0.08Zr0.52Ti0.48O3 (PLZT) films, where the magnetic anisotropy of NiFe can be electrically modified by low voltages. Ferromagnetic resonance measurements confirm that the interfacial charge-mediated magnetoelectric effect is dominant in NiFe/PLZT heterostructures. Non-volatile modification of ferromagnetic resonance field is demonstrated by applying voltage pulses. The ferroelectric switching of magnetic anisotropy exhibits extensive applications in energy-efficient electronic devices such as magnetoelectric random access memories, magnetic field sensors, and tunable radio frequency (RF)/microwave devices.

  17. Non-Volatile Ferroelectric Switching of Ferromagnetic Resonance in NiFe/PLZT Multiferroic Thin Film Heterostructures

    PubMed Central

    Hu, Zhongqiang; Wang, Xinjun; Nan, Tianxiang; Zhou, Ziyao; Ma, Beihai; Chen, Xiaoqin; Jones, John G.; Howe, Brandon M.; Brown, Gail J.; Gao, Yuan; Lin, Hwaider; Wang, Zhiguang; Guo, Rongdi; Chen, Shuiyuan; Shi, Xiaoling; Shi, Wei; Sun, Hongzhi; Budil, David; Liu, Ming; Sun, Nian X.

    2016-01-01

    Magnetoelectric effect, arising from the interfacial coupling between magnetic and electrical order parameters, has recently emerged as a robust means to electrically manipulate the magnetic properties in multiferroic heterostructures. Challenge remains as finding an energy efficient way to modify the distinct magnetic states in a reliable, reversible, and non-volatile manner. Here we report ferroelectric switching of ferromagnetic resonance in multiferroic bilayers consisting of ultrathin ferromagnetic NiFe and ferroelectric Pb0.92La0.08Zr0.52Ti0.48O3 (PLZT) films, where the magnetic anisotropy of NiFe can be electrically modified by low voltages. Ferromagnetic resonance measurements confirm that the interfacial charge-mediated magnetoelectric effect is dominant in NiFe/PLZT heterostructures. Non-volatile modification of ferromagnetic resonance field is demonstrated by applying voltage pulses. The ferroelectric switching of magnetic anisotropy exhibits extensive applications in energy-efficient electronic devices such as magnetoelectric random access memories, magnetic field sensors, and tunable radio frequency (RF)/microwave devices. PMID:27581071

  18. Non-Volatile Ferroelectric Switching of Ferromagnetic Resonance in NiFe/PLZT Multiferroic Thin Film Heterostructures

    NASA Astrophysics Data System (ADS)

    Hu, Zhongqiang; Wang, Xinjun; Nan, Tianxiang; Zhou, Ziyao; Ma, Beihai; Chen, Xiaoqin; Jones, John G.; Howe, Brandon M.; Brown, Gail J.; Gao, Yuan; Lin, Hwaider; Wang, Zhiguang; Guo, Rongdi; Chen, Shuiyuan; Shi, Xiaoling; Shi, Wei; Sun, Hongzhi; Budil, David; Liu, Ming; Sun, Nian X.

    2016-09-01

    Magnetoelectric effect, arising from the interfacial coupling between magnetic and electrical order parameters, has recently emerged as a robust means to electrically manipulate the magnetic properties in multiferroic heterostructures. Challenge remains as finding an energy efficient way to modify the distinct magnetic states in a reliable, reversible, and non-volatile manner. Here we report ferroelectric switching of ferromagnetic resonance in multiferroic bilayers consisting of ultrathin ferromagnetic NiFe and ferroelectric Pb0.92La0.08Zr0.52Ti0.48O3 (PLZT) films, where the magnetic anisotropy of NiFe can be electrically modified by low voltages. Ferromagnetic resonance measurements confirm that the interfacial charge-mediated magnetoelectric effect is dominant in NiFe/PLZT heterostructures. Non-volatile modification of ferromagnetic resonance field is demonstrated by applying voltage pulses. The ferroelectric switching of magnetic anisotropy exhibits extensive applications in energy-efficient electronic devices such as magnetoelectric random access memories, magnetic field sensors, and tunable radio frequency (RF)/microwave devices.

  19. Evaluation of Magnetoresistive RAM for Space Applications

    NASA Technical Reports Server (NTRS)

    Heidecker, Jason

    2014-01-01

    Magnetoresistive random-access memory (MRAM) is a non-volatile memory that exploits electronic spin, rather than charge, to store data. Instead of moving charge on and off a floating gate to alter the threshold voltage of a CMOS transistor (creating different bit states), MRAM uses magnetic fields to flip the polarization of a ferromagnetic material thus switching its resistance and bit state. These polarized states are immune to radiation-induced upset, thus making MRAM very attractive for space application. These magnetic memory elements also have infinite data retention and erase/program endurance. Presented here are results of reliability testing of two space-qualified MRAM products from Aeroflex and Honeywell.

  20. Tunnel junctions with multiferroic barriers

    NASA Astrophysics Data System (ADS)

    Gajek, Martin; Bibes, Manuel; Fusil, Stéphane; Bouzehouane, Karim; Fontcuberta, Josep; Barthélémy, Agnès; Fert, Albert

    2007-04-01

    Multiferroics are singular materials that can exhibit simultaneously electric and magnetic orders. Some are ferroelectric and ferromagnetic and provide the opportunity to encode information in electric polarization and magnetization to obtain four logic states. However, such materials are rare and schemes allowing a simple electrical readout of these states have not been demonstrated in the same device. Here, we show that films of La0.1Bi0.9MnO3 (LBMO) are ferromagnetic and ferroelectric, and retain both ferroic properties down to a thickness of 2nm. We have integrated such ultrathin multiferroic films as barriers in spin-filter-type tunnel junctions that exploit the magnetic and ferroelectric degrees of freedom of LBMO. Whereas ferromagnetism permits read operations reminiscent of magnetic random access memories (MRAM), the electrical switching evokes a ferroelectric RAM write operation. Significantly, our device does not require the destructive ferroelectric readout, and therefore represents an advance over the original four-state memory concept based on multiferroics.

  1. Tunnel junctions with multiferroic barriers.

    PubMed

    Gajek, Martin; Bibes, Manuel; Fusil, Stéphane; Bouzehouane, Karim; Fontcuberta, Josep; Barthélémy, Agnès; Fert, Albert

    2007-04-01

    Multiferroics are singular materials that can exhibit simultaneously electric and magnetic orders. Some are ferroelectric and ferromagnetic and provide the opportunity to encode information in electric polarization and magnetization to obtain four logic states. However, such materials are rare and schemes allowing a simple electrical readout of these states have not been demonstrated in the same device. Here, we show that films of La(0.1)Bi(0.9)MnO(3) (LBMO) are ferromagnetic and ferroelectric, and retain both ferroic properties down to a thickness of 2 nm. We have integrated such ultrathin multiferroic films as barriers in spin-filter-type tunnel junctions that exploit the magnetic and ferroelectric degrees of freedom of LBMO. Whereas ferromagnetism permits read operations reminiscent of magnetic random access memories (MRAM), the electrical switching evokes a ferroelectric RAM write operation. Significantly, our device does not require the destructive ferroelectric readout, and therefore represents an advance over the original four-state memory concept based on multiferroics.

  2. Acoustically assisted spin-transfer-torque switching of nanomagnets: An energy-efficient hybrid writing scheme for non-volatile memory

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Biswas, Ayan K.; Bandyopadhyay, Supriyo; Atulasimha, Jayasimha

    We show that the energy dissipated to write bits in spin-transfer-torque random access memory can be reduced by an order of magnitude if a surface acoustic wave (SAW) is launched underneath the magneto-tunneling junctions (MTJs) storing the bits. The SAW-generated strain rotates the magnetization of every MTJs' soft magnet from the easy towards the hard axis, whereupon passage of a small spin-polarized current through a target MTJ selectively switches it to the desired state with > 99.99% probability at room temperature, thereby writing the bit. The other MTJs return to their original states at the completion of the SAW cycle.

  3. Detrimental effect of interfacial Dzyaloshinskii-Moriya interaction on perpendicular spin-transfer-torque magnetic random access memory

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Jang, Peong-Hwa; Lee, Seo-Won, E-mail: swlee-sci@korea.ac.kr, E-mail: kj-lee@korea.ac.kr; Song, Kyungmi

    2015-11-16

    Interfacial Dzyaloshinskii-Moriya interaction in ferromagnet/heavy metal bilayers is recently of considerable interest as it offers an efficient control of domain walls and the stabilization of magnetic skyrmions. However, its effect on the performance of perpendicular spin transfer torque memory has not been explored yet. We show based on numerical studies that the interfacial Dzyaloshinskii-Moriya interaction decreases the thermal energy barrier while increases the switching current. As high thermal energy barrier as well as low switching current is required for the commercialization of spin torque memory, our results suggest that the interfacial Dzyaloshinskii-Moriya interaction should be minimized for spin torque memorymore » applications.« less

  4. Cap-Induced Magnetic Anisotropy in Ultra-thin Fe/MgO(001) Films

    NASA Astrophysics Data System (ADS)

    Brown-Heft, Tobias; Pendharkar, Mihir; Lee, Elizabeth; Palmstrom, Chris

    Magnetic anisotropy plays an important role in the design of spintronic devices. Perpendicular magnetic anisotropy (PMA) is preferred for magnetic tunnel junctions because the resulting energy barrier between magnetization states can be very high and this allows enhanced device scalability suitable for magnetic random access memory applications. Interface induced anisotropy is often used to control magnetic easy axes. For example, the Fe/MgO(001) system has been predicted to exhibit PMA in the ultrathin Fe limit. We have used in-situ magneto optic Kerr effect and ex-situ SQUID to study the changes in anisotropy constants between bare Fe/MgO(001) films and those capped with MgO, Pt, and Ta. In some cases in-plane anisotropy terms reverse sign after capping. We also observe transitions from superparamagnetic to ferromagnetic behavior induced by capping layers. Perpendicular anisotropy is observed for Pt/Fe/MgO(001) films after annealing to 300°C. These effects are characterized and incorporated into a magnetic simulation that accurately reproduces the behavior of the films. This work was supported in part by the Semiconductor Research Corporation programs (1) MSR-Intel, and (2) C-SPIN.

  5. Tunneling anisotropic magnetoresistance driven by magnetic phase transition.

    PubMed

    Chen, X Z; Feng, J F; Wang, Z C; Zhang, J; Zhong, X Y; Song, C; Jin, L; Zhang, B; Li, F; Jiang, M; Tan, Y Z; Zhou, X J; Shi, G Y; Zhou, X F; Han, X D; Mao, S C; Chen, Y H; Han, X F; Pan, F

    2017-09-06

    The independent control of two magnetic electrodes and spin-coherent transport in magnetic tunnel junctions are strictly required for tunneling magnetoresistance, while junctions with only one ferromagnetic electrode exhibit tunneling anisotropic magnetoresistance dependent on the anisotropic density of states with no room temperature performance so far. Here, we report an alternative approach to obtaining tunneling anisotropic magnetoresistance in α'-FeRh-based junctions driven by the magnetic phase transition of α'-FeRh and resultantly large variation of the density of states in the vicinity of MgO tunneling barrier, referred to as phase transition tunneling anisotropic magnetoresistance. The junctions with only one α'-FeRh magnetic electrode show a magnetoresistance ratio up to 20% at room temperature. Both the polarity and magnitude of the phase transition tunneling anisotropic magnetoresistance can be modulated by interfacial engineering at the α'-FeRh/MgO interface. Besides the fundamental significance, our finding might add a different dimension to magnetic random access memory and antiferromagnet spintronics.Tunneling anisotropic magnetoresistance is promising for next generation memory devices but limited by the low efficiency and functioning temperature. Here the authors achieved 20% tunneling anisotropic magnetoresistance at room temperature in magnetic tunnel junctions with one α'-FeRh magnetic electrode.

  6. The effect of patterning options on embedded memory cells in logic technologies at iN10 and iN7

    NASA Astrophysics Data System (ADS)

    Appeltans, Raf; Weckx, Pieter; Raghavan, Praveen; Kim, Ryoung-Han; Kar, Gouri Sankar; Furnémont, Arnaud; Van der Perre, Liesbet; Dehaene, Wim

    2017-03-01

    Static Random Access Memory (SRAM) cells are used together with logic standard cells as the benchmark to develop the process flow for new logic technologies. In order to achieve successful integration of Spin-Transfer Torque Magnetic Random Access Memory (STT-MRAM) as area efficient higher level embedded cache, it also needs to be included as a benchmark. The simple cell structure of STT-MRAM brings extra patterning challenges to achieve high density. The two memory types are compared in terms of minimum area and critical design rules in both the iN10 and iN7 node, with an extra focus on patterning options in iN7. Both the use of Self-Aligned Quadruple Patterning (SAQP) mandrel and spacer engineering, as well as multi-level via's are explored. These patterning options result in large area gains for the STT-MRAM cell and moreover determine which cell variant is the smallest.

  7. Perpendicular magnetic tunnel junction with a strained Mn-based nanolayer

    PubMed Central

    Suzuki, K. Z.; Ranjbar, R.; Okabayashi, J.; Miura, Y.; Sugihara, A.; Tsuchiura, H.; Mizukami, S.

    2016-01-01

    A magnetic tunnel junction with a perpendicular magnetic easy-axis (p-MTJ) is a key device for spintronic non-volatile magnetoresistive random access memory (MRAM). Co-Fe-B alloy-based p-MTJs are being developed, although they have a large magnetisation and medium perpendicular magnetic anisotropy (PMA), which make it difficult to apply them to a future dense MRAM. Here, we demonstrate a p-MTJ with an epitaxially strained MnGa nanolayer grown on a unique CoGa buffer material, which exhibits a large PMA of more than 5 Merg/cm3 and magnetisation below 500 emu/cm3; these properties are sufficient for application to advanced MRAM. Although the experimental tunnel magnetoresistance (TMR) ratio is still low, first principles calculations confirm that the strain-induced crystal lattice distortion modifies the band dispersion along the tetragonal c-axis into the fully spin-polarised state; thus, a huge TMR effect can be generated in this p-MTJ. PMID:27457186

  8. Influence of thermal agitation on the electric field induced precessional magnetization reversal with perpendicular easy axis

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Cheng, Hongguang, E-mail: chenghg7932@gmail.com; Deng, Ning

    2013-12-15

    We investigated the influence of thermal agitation on the electric field induced precessional magnetization switching probability with perpendicular easy axis by solving the Fokker-Planck equation numerically with finite difference method. The calculated results show that the thermal agitation during the reversal process crucially influences the switching probability. The switching probability can be achieved is only determined by the thermal stability factor Δ of the free layer, it is independent on the device dimension, which is important for the high density device application. Ultra-low error rate down to the order of 10{sup −9} can be achieved for the device of thermalmore » stability factor Δ of 40. Low damping factor α material should be used for the free layer for high reliability device applications. These results exhibit potential of electric field induced precessional magnetization switching with perpendicular easy axis for ultra-low power, high speed and high density magnetic random access memory (MRAM) applications.« less

  9. Al embedded MgO barrier MTJ: A first principle study for application in fast and compact STT-MRAMs

    NASA Astrophysics Data System (ADS)

    Yadav, Manoj Kumar; Gupta, Santosh Kumar; Rai, Sanjeev; Pandey, Avinash C.

    2017-03-01

    The first principle comparative study of a novel single Al sheet embedded MgO and pure MgO barrier having Fe electrodes magnetic tunnel junction has been presented. Al embedded MgO is reported to provide enhanced spin polarised tunnelling current due to increase of spin-polarized density of states at Fermi energy in the barrier region. This novel MTJ provides a current density and resistance area (RA) product of 94.497 ×107 A / cm2 and 0.105  Ω - μm2 respectively. With such a low RA product; it allows higher deriving current due to which switching time of magnetization reversal reduces without inducing barrier related breakdowns in non-volatile magnetic random access memories. The low RA product and high current density of the proposed MTJ may have possible applications in integration with existing MOS circuits.

  10. Fast and efficient STT switching in MTJ using additional transient pulse current

    NASA Astrophysics Data System (ADS)

    Pathak, Sachin; Cha, Jongin; Jo, Kangwook; Yoon, Hongil; Hong, Jongill

    2017-06-01

    We propose a profile of write pulse current-density to switch magnetization in a perpendicular magnetic tunnel junction to reduce switching time and write energy as well. Our simulated results show that an overshoot transient pulse current-density (current spike) imposed to conventional rectangular-shaped pulse current-density (main pulse) significantly improves switching speed that yields the reduction in write energy accordingly. For example, we could dramatically reduce the switching time by 80% and thereby reduce the write energy over 9% in comparison to the switching without current spike. The current spike affects the spin dynamics of the free layer and reduces the switching time mainly due to spin torque induced. On the other hand, the large Oersted field induced causes changes in spin texture. We believe our proposed write scheme can make a breakthrough in magnetic random access memory technology seeking both high speed operation and low energy consumption.

  11. Giant self-biased converse magnetoelectric effect in multiferroic heterostructure with single-phase magnetostrictive materials

    NASA Astrophysics Data System (ADS)

    Zhang, Jitao; Li, Ping; Wen, Yumei; He, Wei; Yang, Aichao; Wang, Decai; Yang, Chao; Lu, Caijiang

    2014-10-01

    Giant self-biased converse magnetoelectric (CME) effects with obvious hysteretic behaviors are systematically investigated in two-phase SmFe2/PZT [Pb(Zr1-x, Tix)O3] multiferroic laminates at room temperature. Taking advantage of the huge anisotropic field of SmFe2 plate, large remnant CME coupling is provoked by this field instead of permanent magnets to bias the laminate. Consequently, bitable magnetization status switching is realized through a smaller ac voltage far below the electric coercive field in the absence of magnetic bias field. Experiments demonstrate that a large remnant CME coefficient (αCME) of 0.007 mG/V is achieved, exhibiting ˜50 times higher CME coefficient than the previous laminate composite multi-phase magnetostrictive plates. These results provide promising applications for realization of high-density magnetoelectric random access memories (MERAMs) devices with lower energy consumption.

  12. Spin-transfer torque in multiferroic tunnel junctions with composite dielectric/ferroelectric barriers

    NASA Astrophysics Data System (ADS)

    Velev, Julian P.; Merodio, Pablo; Pollack, Cesar; Kalitsov, Alan; Chshiev, Mairbek; Kioussis, Nicholas

    2017-12-01

    Using model calculations, we demonstrate a very high level of control of the spin-transfer torque (STT) by electric field in multiferroic tunnel junctions with composite dielectric/ferroelectric barriers. We find that, for particular device parameters, toggling the polarization direction can switch the voltage-induced part of STT between a finite value and a value close to zero, i.e. quench and release the torque. Additionally, we demonstrate that under certain conditions the zero-voltage STT, i.e. the interlayer exchange coupling, can switch sign with polarization reversal, which is equivalent to reversing the magnetic ground state of the tunnel junction. This bias- and polarization-tunability of the STT could be exploited to engineer novel functionalities such as softening/hardening of the bit or increasing the signal-to-noise ratio in magnetic sensors, which can have important implications for magnetic random access memories or for combined memory and logic devices.

  13. Non-Volatile Memory Technology Symposium 2001: Proceedings

    NASA Technical Reports Server (NTRS)

    Aranki, Nazeeh; Daud, Taher; Strauss, Karl

    2001-01-01

    This publication contains the proceedings for the Non-Volatile Memory Technology Symposium 2001 that was held on November 7-8, 2001 in San Diego, CA. The proceedings contains a a wide range of papers that cover current and new memory technologies including Flash memories, Magnetic Random Access Memories (MRAM and GMRAM), Ferro-electric RAM (FeRAM), and Chalcogenide RAM (CRAM). The papers presented in the proceedings address the use of these technologies for space applications as well as radiation effects and packaging issues.

  14. Enhancement of switching stability of tunneling magnetoresistance system with artificial ferrimagnet

    NASA Astrophysics Data System (ADS)

    You, Chun-Yeol; Bader, Sam. D.; Scheinfein, M. R.

    2002-03-01

    In the study of spin dependent magnetic tunneling junctions, the switching stability of the magnetically hard layer is a crucial issue in magnetic random access memory applications[1]. After repeated cycling of the soft layer, the magnetization of the hard layer is demagnetized by the stray field from the domain wall created during the switching[2]. The magnitude of the stray field from the soft layer is large enough to switch a domain in the hard layer. Therefore, reducing this stray field is necessary to increase the switching stability. In this study, we explore an artificial ferrimagnet to replace the usual soft layer in order to reduce stray field. The ferrimagnet consists of an antiferromagnetically coupled trilayer that has two ferromagnetic layers of unequal thickness and opposite magnetization orientation. Since the sign of stray field of the two ferromagnetic layers is opposed, the total stray field is greatly reduced. [Supported by the US DOE, BES-MS, under Contract W-31-109-ENG-38.] [1] S. Gider et al. Science 281, 797 (1998). [2] L. Thomas et al. Phys. Rev. Lett. 84, 1816 (2000).

  15. Breakthrough in current-in-plane tunneling measurement precision by application of multi-variable fitting algorithm.

    PubMed

    Cagliani, Alberto; Østerberg, Frederik W; Hansen, Ole; Shiv, Lior; Nielsen, Peter F; Petersen, Dirch H

    2017-09-01

    We present a breakthrough in micro-four-point probe (M4PP) metrology to substantially improve precision of transmission line (transfer length) type measurements by application of advanced electrode position correction. In particular, we demonstrate this methodology for the M4PP current-in-plane tunneling (CIPT) technique. The CIPT method has been a crucial tool in the development of magnetic tunnel junction (MTJ) stacks suitable for magnetic random-access memories for more than a decade. On two MTJ stacks, the measurement precision of resistance-area product and tunneling magnetoresistance was improved by up to a factor of 3.5 and the measurement reproducibility by up to a factor of 17, thanks to our improved position correction technique.

  16. The effect of growth sequence on magnetization damping in Ta/CoFeB/MgO structures

    NASA Astrophysics Data System (ADS)

    Liu, Bo; Huang, Dawei; Gao, Ming; Tu, Hongqing; Wang, Kejie; Ruan, Xuezhong; Du, Jun; Cai, Jian-Wang; He, Liang; Wu, Jing; Wang, Xinran; Xu, Yongbing

    2018-03-01

    Magnetization damping is a key parameter to control the critical current and the switching speed in magnetic random access memory, and here we report the effect of the growth sequence on the magnetic dynamics properties of perpendicularly magnetized Ta/CoFeB/MgO structures. Ultrathin CoFeB films have been grown between Ta and MgO but with different stack sequences, i.e. substrate/Ta/CoFeB/MgO/Ta and substrate/Ta/MgO/CoFeB/Ta. The magnetization dynamics induced by femtosecond laser was investigated by using all-optical pump-probe measurements. We found that the Gilbert damping constant was modulated by reversing stack structures, which offers the potential to tune the damping parameter by the growth sequence. The Gilbert damping constant was enhanced from 0.017 for substrate/Ta/CoFeB/MgO/Ta to 0.027 for substrate/Ta/MgO/CoFeB/Ta. We believe that this enhancement originates from the increase of intermixing at the CoFeB/Ta when the Ta atom layer was grown after the CoFeB layer.

  17. Spontaneous nucleation and topological stabilization of skyrmions in magnetic nanodisks with the interfacial Dzyaloshinskii-Moriya interaction

    NASA Astrophysics Data System (ADS)

    Kolesnikov, A. G.; Samardak, A. S.; Stebliy, M. E.; Ognev, A. V.; Chebotkevich, L. A.; Sadovnikov, A. V.; Nikitov, S. A.; Kim, Yong Jin; Cha, In Ho; Kim, Young Keun

    2017-05-01

    One of the major societal challenges is reducing the power consumption of information technology (IT) devices and numerous data centers. Distinct from the current approaches based on switching of magnetic single-domain nanostructures or on movement of domain walls under high currents, an original magnetic skyrmion technology offers ultra-low power, fast, high-density, and scalable spintronic devices, including non-volatile random access memory. Using data-driven micromagnetic simulations, we demonstrate the possibility of spontaneous nucleation and stabilization of different skyrmionic states, such as skyrmions, merons, and meron-like configurations, in heavy metal/ferromagnetic nanodisks with the interfacial Dzyaloshinskii-Moriya interaction (iDMI) as a result of quasi-static magnetization reversal only. Since iDMI is not easily modulated in real systems, we show that skyrmion stabilization is easily achievable by manipulating magnetic anisotropy, saturation magnetization, and the diameters of nanodisks. The state diagrams, presented in terms of the topological charge, allow to explicitly distinguish the intermediate states between skyrmions and merons and can be used for developing a skyrmionic medium, which has been recently proposed to be a building block for future spin-orbitronic devices.

  18. Enhanced voltage-controlled magnetic anisotropy in magnetic tunnel junctions with an MgO/PZT/MgO tunnel barrier

    NASA Astrophysics Data System (ADS)

    Chien, Diana; Li, Xiang; Wong, Kin; Zurbuchen, Mark A.; Robbennolt, Shauna; Yu, Guoqiang; Tolbert, Sarah; Kioussis, Nicholas; Khalili Amiri, Pedram; Wang, Kang L.; Chang, Jane P.

    2016-03-01

    Compared with current-controlled magnetization switching in a perpendicular magnetic tunnel junction (MTJ), electric field- or voltage-induced magnetization switching reduces the writing energy of the memory cell, which also results in increased memory density. In this work, an ultra-thin PZT film with high dielectric constant was integrated into the tunneling oxide layer to enhance the voltage-controlled magnetic anisotropy (VCMA) effect. The growth of MTJ stacks with an MgO/PZT/MgO tunnel barrier was performed using a combination of sputtering and atomic layer deposition techniques. The fabricated MTJs with the MgO/PZT/MgO barrier demonstrate a VCMA coefficient, which is ˜40% higher (19.8 ± 1.3 fJ/V m) than the control sample MTJs with an MgO barrier (14.3 ± 2.7 fJ/V m). The MTJs with the MgO/PZT/MgO barrier also possess a sizeable tunneling magnetoresistance (TMR) of more than 50% at room temperature, comparable to the control MTJs with an MgO barrier. The TMR and enhanced VCMA effect demonstrated simultaneously in this work make the MgO/PZT/MgO barrier-based MTJs potential candidates for future voltage-controlled, ultralow-power, and high-density magnetic random access memory devices.

  19. Voltage-controlled magnetization switching in MRAMs in conjunction with spin-transfer torque and applied magnetic field

    NASA Astrophysics Data System (ADS)

    Munira, Kamaram; Pandey, Sumeet C.; Kula, Witold; Sandhu, Gurtej S.

    2016-11-01

    Voltage-controlled magnetic anisotropy (VCMA) effect has attracted a significant amount of attention in recent years because of its low cell power consumption during the anisotropy modulation of a thin ferromagnetic film. However, the applied voltage or electric field alone is not enough to completely and reliably reverse the magnetization of the free layer of a magnetic random access memory (MRAM) cell from anti-parallel to parallel configuration or vice versa. An additional symmetry-breaking mechanism needs to be employed to ensure the deterministic writing process. Combinations of voltage-controlled magnetic anisotropy together with spin-transfer torque (STT) and with an applied magnetic field (Happ) were evaluated for switching reliability, time taken to switch with low error rate, and energy consumption during the switching process. In order to get a low write error rate in the MRAM cell with VCMA switching mechanism, a spin-transfer torque current or an applied magnetic field comparable to the critical current and field of the free layer is necessary. In the hybrid processes, the VCMA effect lowers the duration during which the higher power hungry secondary mechanism is in place. Therefore, the total energy consumed during the hybrid writing processes, VCMA + STT or VCMA + Happ, is less than the energy consumed during pure spin-transfer torque or applied magnetic field switching.

  20. Review of multi-layered magnetoelectric composite materials and devices applications

    NASA Astrophysics Data System (ADS)

    Chu, Zhaoqiang; PourhosseiniAsl, MohammadJavad; Dong, Shuxiang

    2018-06-01

    Multiferroic materials with the coexistence of at least two ferroic orders, such as ferroelectricity, ferromagnetism, or ferroelasticity, have recently attracted ever-increasing attention due to their potential for multifunctional device applications, including magnetic and current sensors, energy harvesters, magnetoelectric (ME) random access memory and logic devices, tunable microwave devices, and ME antenna. In this article, we provide a review of the recent and ongoing research efforts in the field of multi-layered ME composites. After a brief introduction to ME composites and ME coupling mechanisms, we review recent advances in multi-layered ME composites as well as their device applications based on the direct ME effect, magnetic sensors in particular. Finally, some remaining challenges and future perspective of ME composites and their engineering applications will be discussed.

  1. Conductance Quantization in Resistive Random Access Memory

    NASA Astrophysics Data System (ADS)

    Li, Yang; Long, Shibing; Liu, Yang; Hu, Chen; Teng, Jiao; Liu, Qi; Lv, Hangbing; Suñé, Jordi; Liu, Ming

    2015-10-01

    The intrinsic scaling-down ability, simple metal-insulator-metal (MIM) sandwich structure, excellent performances, and complementary metal-oxide-semiconductor (CMOS) technology-compatible fabrication processes make resistive random access memory (RRAM) one of the most promising candidates for the next-generation memory. The RRAM device also exhibits rich electrical, thermal, magnetic, and optical effects, in close correlation with the abundant resistive switching (RS) materials, metal-oxide interface, and multiple RS mechanisms including the formation/rupture of nanoscale to atomic-sized conductive filament (CF) incorporated in RS layer. Conductance quantization effect has been observed in the atomic-sized CF in RRAM, which provides a good opportunity to deeply investigate the RS mechanism in mesoscopic dimension. In this review paper, the operating principles of RRAM are introduced first, followed by the summarization of the basic conductance quantization phenomenon in RRAM and the related RS mechanisms, device structures, and material system. Then, we discuss the theory and modeling of quantum transport in RRAM. Finally, we present the opportunities and challenges in quantized RRAM devices and our views on the future prospects.

  2. Cross-point-type spin-transfer-torque magnetoresistive random access memory cell with multi-pillar vertical body channel MOSFET

    NASA Astrophysics Data System (ADS)

    Sasaki, Taro; Endoh, Tetsuo

    2018-04-01

    In this paper, from the viewpoint of cell size and sensing margin, the impact of a novel cross-point-type one transistor and one magnetic tunnel junction (1T–1MTJ) spin-transfer-torque magnetoresistive random access memory (STT-MRAM) cell with a multi-pillar vertical body channel (BC) MOSFET is shown for high density and wide sensing margin STT-MRAM, with a 10 ns writing period and 1.2 V V DD. For that purpose, all combinations of n/p-type MOSFETs and bottom/top-pin MTJs are compared, where the diameter of MTJ (D MTJ) is scaled down from 55 to 15 nm and the tunnel magnetoresistance (TMR) ratio is increased from 100 to 200%. The results show that, benefiting from the proposed STT-MRAM cell with no back bias effect, the MTJ with a high TMR ratio (200%) can be used in the design of smaller STT-MRAM cells (over 72.6% cell size reduction), which is a difficult task for conventional planar MOSFET based design.

  3. Conductance Quantization in Resistive Random Access Memory.

    PubMed

    Li, Yang; Long, Shibing; Liu, Yang; Hu, Chen; Teng, Jiao; Liu, Qi; Lv, Hangbing; Suñé, Jordi; Liu, Ming

    2015-12-01

    The intrinsic scaling-down ability, simple metal-insulator-metal (MIM) sandwich structure, excellent performances, and complementary metal-oxide-semiconductor (CMOS) technology-compatible fabrication processes make resistive random access memory (RRAM) one of the most promising candidates for the next-generation memory. The RRAM device also exhibits rich electrical, thermal, magnetic, and optical effects, in close correlation with the abundant resistive switching (RS) materials, metal-oxide interface, and multiple RS mechanisms including the formation/rupture of nanoscale to atomic-sized conductive filament (CF) incorporated in RS layer. Conductance quantization effect has been observed in the atomic-sized CF in RRAM, which provides a good opportunity to deeply investigate the RS mechanism in mesoscopic dimension. In this review paper, the operating principles of RRAM are introduced first, followed by the summarization of the basic conductance quantization phenomenon in RRAM and the related RS mechanisms, device structures, and material system. Then, we discuss the theory and modeling of quantum transport in RRAM. Finally, we present the opportunities and challenges in quantized RRAM devices and our views on the future prospects.

  4. 76 FR 73676 - Certain Dynamic Random Access Memory Devices, and Products Containing Same; Receipt of Complaint...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-11-29

    ... INTERNATIONAL TRADE COMMISSION [DN 2859] Certain Dynamic Random Access Memory Devices, and.... International Trade Commission has received a complaint entitled In Re Certain Dynamic Random Access Memory... certain dynamic random access memory devices, and products containing same. The complaint names Elpida...

  5. 75 FR 16507 - In the Matter of Certain Semiconductor Chips Having Synchronous Dynamic Random Access Memory...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-04-01

    ... Semiconductor Chips Having Synchronous Dynamic Random Access Memory Controllers and Products Containing Same... synchronous dynamic random access memory controllers and products containing same by reason of infringement of... semiconductor chips having synchronous dynamic random access memory controllers and products containing same...

  6. Enhancing current-induced torques by abutting additional spin polarizer layer to nonmagnetic metal layer

    NASA Astrophysics Data System (ADS)

    Go, Gyungchoon; Lee, Kyung-Jin; Kim, Young Keun

    2017-04-01

    Recently, the switching of a perpendicularly magnetized ferromagnet (FM) by injecting an in-plane current into an attached non-magnet (NM) has become of emerging technological interest. This magnetization switching is attributed to the spin-orbit torque (SOT) originating from the strong spin-orbit coupling of the NM layer. However, the switching efficiency of the NM/FM structure itself may be insufficient for practical use, as for example, in spin transfer torque (STT)-based magnetic random access memory (MRAM) devices. Here we investigate spin torque in an NM/FM structure with an additional spin polarizer (SP) layer abutted to the NM layer. In addition to the SOT contribution, a spin-polarized current from the SP layer creates an extra spin chemical potential difference at the NM/FM interface and gives rise to a STT on the FM layer. We show that, using typical parameters including device width, thickness, spin diffusion length, and the spin Hall angle, the spin torque from the SP layer can be much larger than that from the spin Hall effect (SHE) of the NM.

  7. A hybrid magnetic/complementary metal oxide semiconductor three-context memory bit cell for non-volatile circuit design

    NASA Astrophysics Data System (ADS)

    Jovanović, B.; Brum, R. M.; Torres, L.

    2014-04-01

    After decades of continued scaling to the beat of Moore's law, it now appears that conventional silicon based devices are approaching their physical limits. In today's deep-submicron nodes, a number of short-channel and quantum effects are emerging that affect the manufacturing process, as well as, the functionality of the microelectronic systems-on-chip. Spintronics devices that exploit both the intrinsic spin of the electron and its associated magnetic moment, in addition to its fundamental electronic charge, are promising solutions to circumvent these scaling threats. Being compatible with the CMOS technology, such devices offer a promising synergy of radiation immunity, infinite endurance, non-volatility, increased density, etc. In this paper, we present a hybrid (magnetic/CMOS) cell that is able to store and process data both electrically and magnetically. The cell is based on perpendicular spin-transfer torque magnetic tunnel junctions (STT-MTJs) and is suitable for use in magnetic random access memories and reprogrammable computing (non-volatile registers, processor cache memories, magnetic field-programmable gate arrays, etc). To demonstrate the potential our hybrid cell, we physically implemented a small hybrid memory block using 45 nm × 45 nm round MTJs for the magnetic part and 28 nm fully depleted silicon on insulator (FD-SOI) technology for the CMOS part. We also report the cells measured performances in terms of area, robustness, read/write speed and energy consumption.

  8. Perpendicular magnetic anisotropy at transition metal/oxide interfaces and applications

    NASA Astrophysics Data System (ADS)

    Dieny, B.; Chshiev, M.

    2017-04-01

    Spin electronics is a rapidly expanding field stimulated by a strong synergy between breakthrough basic research discoveries and industrial applications in the fields of magnetic recording, magnetic field sensors, nonvolatile memories [magnetic random access memories (MRAM) and especially spin-transfer-torque MRAM (STT-MRAM)]. In addition to the discovery of several physical phenomena (giant magnetoresistance, tunnel magnetoresistance, spin-transfer torque, spin-orbit torque, spin Hall effect, spin Seebeck effect, etc.), outstanding progress has been made on the growth and nanopatterning of magnetic multilayered films and nanostructures in which these phenomena are observed. Magnetic anisotropy is usually observed in materials that have large spin-orbit interactions. However, in 2002 perpendicular magnetic anisotropy (PMA) was discovered to exist at magnetic metal/oxide interfaces [for instance Co (Fe )/alumina ]. Surprisingly, this PMA is observed in systems where spin-orbit interactions are quite weak, but its amplitude is remarkably large—comparable to that measured at Co /Pt interfaces, a reference for large interfacial anisotropy (anisotropy˜1.4 erg /cm2=1.4 mJ /m2 ). Actually, this PMA was found to be very common at magnetic metal/oxide interfaces since it has been observed with a large variety of amorphous or crystalline oxides, including AlOx, MgO, TaOx, HfOx, etc. This PMA is thought to be the result of electronic hybridization between the oxygen and the magnetic transition metal orbit across the interface, a hypothesis supported by ab initio calculations. Interest in this phenomenon was sparked in 2010 when it was demonstrated that the PMA at magnetic transition metal/oxide interfaces could be used to build out-of-plane magnetized magnetic tunnel junctions for STT-MRAM cells. In these systems, the PMA at the CoFeB /MgO interface can be used to simultaneously obtain good memory retention, thanks to the large PMA amplitude, and a low write current, thanks to a relatively weak Gilbert damping. These two requirements for memories tend to be difficult to reconcile since they rely on the same spin-orbit coupling. PMA-based approaches have now become ubiquitous in the designs for perpendicular STT-MRAM, and major microelectronics companies are actively working on their development with the first goal of addressing embedded FLASH and static random access memory-type of applications. Scalability of STT-MRAM devices based on this interfacial PMA is expected to soon exceed the 20-nm nodes. Several very active new fields of research also rely on interfacial PMA at magnetic metal/oxide interfaces, including spin-orbit torques associated with Rashba or spin Hall effects, record high speed domain wall propagation in buffer/magnetic metal/oxide-based magnetic wires, and voltage-based control of anisotropy. This review deals with PMA at magnetic metal/oxide interfaces from its discovery, by examining the diversity of systems in which it has been observed and the physicochemical methods through which the key roles played by the electronic hybridization at the metal/oxide interface were elucidated. The physical origins of the phenomenon are also covered and how these are supported by ab initio calculations is dealt with. Finally, some examples of applications of this interfacial PMA in STT-MRAM are listed along with the various emerging research topics taking advantage of this PMA.

  9. 76 FR 80964 - Certain Dynamic Random Access Memory Devices, and Products Containing Same; Institution of...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-12-27

    ... INTERNATIONAL TRADE COMMISSION [Investigation No. 337-TA-821] Certain Dynamic Random Access Memory... importation, and the sale within the United States after importation of certain dynamic random access memory... certain dynamic random access memory devices, and products containing same that infringe one or more of...

  10. Three-dimensional magnetic bubble memory system

    NASA Technical Reports Server (NTRS)

    Stadler, Henry L. (Inventor); Katti, Romney R. (Inventor); Wu, Jiin-Chuan (Inventor)

    1994-01-01

    A compact memory uses magnetic bubble technology for providing data storage. A three-dimensional arrangement, in the form of stacks of magnetic bubble layers, is used to achieve high volumetric storage density. Output tracks are used within each layer to allow data to be accessed uniquely and unambiguously. Storage can be achieved using either current access or field access magnetic bubble technology. Optical sensing via the Faraday effect is used to detect data. Optical sensing facilitates the accessing of data from within the three-dimensional package and lends itself to parallel operation for supporting high data rates and vector and parallel processing.

  11. Tunnel Magneto Resistance of Fe/Insulator/Fe

    NASA Astrophysics Data System (ADS)

    Aryee, Dennis; Seifu, Dereje

    Tri-layer thin films of Fe/Insulator/Fe were synthesized using magnetron DC/ RF sputtering with MgO insulator and Bi2Te3 topological insulators as middle buffer layer. The multi-layered samples thus produced were studied using in-house built magneto-optic Kerr effect (MOKE) instrument, vibrating sample magnetometer (VSM), torque magnetometer (TMM), AFM, MFM, and magneto-resistance (MR). This system, that is Fe/Insulator/Fe on MgO(100) substrate, is a well-known tunnel magneto resistance (TMR) structure often used in magnetic tunnel junction (MTJ) devices. TMR effect is a method by which MTJs are used in developing magneto-resistive random access memory (MRAM), magnetic sensors, and novel logic devices. The main purpose behind this research is to measure the magnetic anisotropy of Fe/Insulator /Fe structure and correlate it to magneto-resistance. In this presentation, we will present results from MOKE, VSM, TMM, AFM, MFM, and MR studies of Fe/Insulator/Fe on MgO(100). We would like to acknowledge support by NSF-MRI-DMR-1337339.

  12. SELF-ORGANIZED BRAIDING AND THE STRUCTURE OF CORONAL LOOPS

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Berger, Mitchell A.; Asgari-Targhi, Mahboubeh, E-mail: m.berger@exeter.ac.u, E-mail: m.asgari@ucl.ac.u

    2009-11-01

    The Parker model for heating of the solar corona involves reconnection of braided magnetic flux elements. Much of this braiding is thought to occur at as yet unresolved scales, for example, braiding of threads within an extreme-ultraviolet or X-ray loop. However, some braiding may be still visible at scales accessible to TRACE or Hinode. We suggest that attempts to estimate the amount of braiding at these scales must take into account the degree of coherence of the braid structure. In this paper, we examine the effect of reconnection on the structure of a braided magnetic field. We demonstrate that simplemore » models of braided magnetic fields which balance the input of topological structure with reconnection evolve to a self-organized critical state. An initially random braid can become highly ordered, with coherence lengths obeying power-law distributions. The energy released during reconnection also obeys a power law. Our model gives more frequent (but smaller) energy releases nearer to the ends of a coronal loop.« less

  13. Perpendicular magnetic anisotropy in Mn2VIn (001) films: An ab initio study

    NASA Astrophysics Data System (ADS)

    Zipporah, Muthui; Robinson, Musembi; Julius, Mwabora; Arti, Kashyap

    2018-05-01

    First principles study of the magnetic anisotropy of Mn2VIn (001) films show perpendicular magnetic anisotropy (PMA), which increases as a function of the thickness of the film. Density functional theory (DFT) as implemented in the Vienna Ab initio simulation package (VASP) is employed here to perform a comprehensive theoretical investigation of the structural, electronic and magnetic properties of the Mn2VIn(001) films of varying thickness. Our calculations were performed on fully relaxed structures, with five to seventeen mono layers (ML). The degree of spin polarization is higher in the (001) Mn2VIn thin films as compared to the bulk in contrast to what is usually the case and as in Mn2VAl, which is isoelectronic to Mn2VIn as well as inCo2VIn (001) films studied for comparison. Tetragonal distortions are found in all the systems after relaxation. The distortion in the Mn2VIn system persists even for the 17ML thin film, resulting in PMA in the Mn2VIn system. This significant finding has potential to contribute to spin transfer torque (STT) and magnetic random access memory MRAM applications, as materials with PMA derived from volume magnetocrystalline anisotropy are being proposed as ideal magnetic electrodes.

  14. Micromagnetism in a planar system with a random magnetic anisotropy and two-dimensional magnetic correlations

    NASA Astrophysics Data System (ADS)

    Komogortsev, S. V.; Fel'k, V. A.; Iskhakov, R. S.; Shadrina, G. V.

    2017-08-01

    The hysteresis loops and the micromagnetic structure of a ferromagnetic nanolayer with a randomly oriented local easy magnetization axis and two-dimensional magnetization correlations are studied using a micromagnetic simulation. The properties and the micromagnetic structure of the nanolayer are determined by the competition between the anisotropy and exchange energies and by the dipole-dipole interaction energy. The magnetic microstructure can be described as an ensemble of stochastic magnetic domains and topological magnetization defects. Dipole-dipole interaction suppresses the formation of topological magnetization defects. The topological defects in the magnetic microstructure can cause a sharper change in the coercive force with the crystallite size than that predicted by the random magnetic anisotropy model.

  15. The interrelationship of organizational characteristics of magnet hospitals, nursing leadership, and nursing job satisfaction.

    PubMed

    Upenieks, Valda V

    2003-01-01

    This study examined whether magnet hospitals continue to provide higher levels of job satisfaction and empowerment among nurses when compared with non-magnet hospitals. Also studied at both types of hospitals was whether job satisfaction discrepancy was interlinked with leadership effectiveness and support of professional nursing practice. Nurses employed at magnet hospitals experienced higher levels of empowerment and job satisfaction due to greater access to work empowerment structures. The elements accounting for differences in empowerment and job satisfaction scores included: (1) greater accessibility of magnet nurse leaders, (2) better support of clinical nurse autonomous decision making by magnet nurse leaders, and (3) greater access to work empowerment structures such as opportunity, information, and resources at magnet hospitals.

  16. Room-temperature antiferromagnetic memory resistor.

    PubMed

    Marti, X; Fina, I; Frontera, C; Liu, Jian; Wadley, P; He, Q; Paull, R J; Clarkson, J D; Kudrnovský, J; Turek, I; Kuneš, J; Yi, D; Chu, J-H; Nelson, C T; You, L; Arenholz, E; Salahuddin, S; Fontcuberta, J; Jungwirth, T; Ramesh, R

    2014-04-01

    The bistability of ordered spin states in ferromagnets provides the basis for magnetic memory functionality. The latest generation of magnetic random access memories rely on an efficient approach in which magnetic fields are replaced by electrical means for writing and reading the information in ferromagnets. This concept may eventually reduce the sensitivity of ferromagnets to magnetic field perturbations to being a weakness for data retention and the ferromagnetic stray fields to an obstacle for high-density memory integration. Here we report a room-temperature bistable antiferromagnetic (AFM) memory that produces negligible stray fields and is insensitive to strong magnetic fields. We use a resistor made of a FeRh AFM, which orders ferromagnetically roughly 100 K above room temperature, and therefore allows us to set different collective directions for the Fe moments by applied magnetic field. On cooling to room temperature, AFM order sets in with the direction of the AFM moments predetermined by the field and moment direction in the high-temperature ferromagnetic state. For electrical reading, we use an AFM analogue of the anisotropic magnetoresistance. Our microscopic theory modelling confirms that this archetypical spintronic effect, discovered more than 150 years ago in ferromagnets, is also present in AFMs. Our work demonstrates the feasibility of fabricating room-temperature spintronic memories with AFMs, which in turn expands the base of available magnetic materials for devices with properties that cannot be achieved with ferromagnets.

  17. Cosmic Rays in Intermittent Magnetic Fields

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Shukurov, Anvar; Seta, Amit; Bushby, Paul J.

    The propagation of cosmic rays in turbulent magnetic fields is a diffusive process driven by the scattering of the charged particles by random magnetic fluctuations. Such fields are usually highly intermittent, consisting of intense magnetic filaments and ribbons surrounded by weaker, unstructured fluctuations. Studies of cosmic-ray propagation have largely overlooked intermittency, instead adopting Gaussian random magnetic fields. Using test particle simulations, we calculate cosmic-ray diffusivity in intermittent, dynamo-generated magnetic fields. The results are compared with those obtained from non-intermittent magnetic fields having identical power spectra. The presence of magnetic intermittency significantly enhances cosmic-ray diffusion over a wide range of particlemore » energies. We demonstrate that the results can be interpreted in terms of a correlated random walk.« less

  18. Magnetic Random Access Memory for Embedded Computing

    DTIC Science & Technology

    2007-10-29

    layer, w he free layer hose resistan .  ce  2. Develop and model  data  storage circuits  based  on the MTJ cells. 3. Integrated the MTJ cells into a CMOS...suggested the two methods shown in Fig. 4.5 [95]. The circuit shown at the top of the figure uses NMOS pass transistors to load data , which is the simplest... method but requires careful design to avoid charge sharing and accommodate the data -dependent loading seen at the DATA input. With additional

  19. Ferromagnetic clusters induced by a nonmagnetic random disorder in diluted magnetic semiconductors

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Bui, Dinh-Hoi; Physics Department, Hue University’s College of Education, 34 Le Loi, Hue; Phan, Van-Nham, E-mail: phanvannham@dtu.edu.vn

    In this work, we analyze the nonmagnetic random disorder leading to a formation of ferromagnetic clusters in diluted magnetic semiconductors. The nonmagnetic random disorder arises from randomness in the host lattice. Including the disorder to the Kondo lattice model with random distribution of magnetic dopants, the ferromagnetic–paramagnetic transition in the system is investigated in the framework of dynamical mean-field theory. At a certain low temperature one finds a fraction of ferromagnetic sites transiting to the paramagnetic state. Enlarging the nonmagnetic random disorder strength, the paramagnetic regimes expand resulting in the formation of the ferromagnetic clusters.

  20. Electric field induced reversible 180° magnetization switching through tuning of interfacial exchange bias along magnetic easy-axis in multiferroic laminates

    PubMed Central

    Xue, Xu; Zhou, Ziyao; Peng, Bin; Zhu, Mingmin; Zhang, Yijun; Ren, Wei; Ren, Tao; Yang, Xi; Nan, Tianxiang; Sun, Nian X.; Liu, Ming

    2015-01-01

    E-field control of interfacial exchange coupling and deterministic switching of magnetization have been demonstrated in two sets of ferromagnetic(FM)/antiferromagnetic(AFM)/ferroelectric(FE) multiferroic heterostructures, including NiFe/NiCoO/glass/PZN-PT (011) and NiFe/FeMn/glass/PZN-PT (011). We designed this experiment to achieve exchange bias tuning along the magnetic easy axis, which is critical for realizing reversible 180° magnetization deterministic switching at zero or small magnetic bias. Strong exchange coupling were established across AFM-FM interfaces, which plays an important role in voltage control of magnetization switching. Through the competition between the E-field induced uniaxial anisotropy in ferromagnetic layer and unidirectional anisotropy in antiferromagnetic layer, the exchange bias was significantly shifted by up to |∆Hex|/Hex = 8% in NiFe/FeMn/glass/PZN-PT (011) and 13% in NiFe/NiCoO/glass/PZN-PT (011). In addition, the square shape of the hysteresis loop, as well as a strong shape tunability of |∆Hex|/Hc = 67.5 ~ 125% in NiFe/FeMn/glass/PZN-PT and 30 ~ 38% in NiFe/NiCoO/glass/PZN-PT were achieved, which lead to a near 180° magnetization switching. Electrical tuning of interfacial exchange coupling in FM/AFM/FE systems paves a new way for realizing magnetoelectric random access memories and other memory technologies. PMID:26576658

  1. Electric field induced reversible 180° magnetization switching through tuning of interfacial exchange bias along magnetic easy-axis in multiferroic laminates

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Xue, Xu; Zhou, Ziyao; Peng, Bin

    2015-11-18

    E-field control of interfacial exchange coupling and deterministic switching of magnetization have been demonstrated in two sets of ferromagnetic(FM)/antiferromagnetic(AFM)/ferroelectric(FE) multiferroic heterostructures, including NiFe/NiCoO/glass/PZN-PT (011) and NiFe/FeMn/glass/PZN-PT (011). We designed this experiment to achieve exchange bias tuning along the magnetic easy axis, which is critical for realizing reversible 180° magnetization deterministic switching at zero or small magnetic bias. Strong exchange coupling were established across AFM-FM interfaces, which plays an important role in voltage control of magnetization switching. Through the competition between the E-field induced uniaxial anisotropy in ferromagnetic layer and unidirectional anisotropy in antiferromagnetic layer, the exchange bias was significantly shiftedmore » by up to |ΔH ex|/H ex=8% in NiFe/FeMn/glass/PZN-PT (011) and 13% in NiFe/NiCoO/glass/PZN-PT (011). In addition, the square shape of the hysteresis loop, as well as a strong shape tunability of |ΔH ex|/H c=67.5~125% in NiFe/FeMn/glass/PZN-PT and 30~38% in NiFe/NiCoO/glass/PZN-PT were achieved, which lead to a near 180° magnetization switching. Lastly, electrical tuning of interfacial exchange coupling in FM/AFM/FE systems paves a new way for realizing magnetoelectric random access memories and other memory technologies.« less

  2. Electric field induced reversible 180° magnetization switching through tuning of interfacial exchange bias along magnetic easy-axis in multiferroic laminates

    NASA Astrophysics Data System (ADS)

    Xue, Xu; Zhou, Ziyao; Peng, Bin; Zhu, Mingmin; Zhang, Yijun; Ren, Wei; Ren, Tao; Yang, Xi; Nan, Tianxiang; Sun, Nian X.; Liu, Ming

    2015-11-01

    E-field control of interfacial exchange coupling and deterministic switching of magnetization have been demonstrated in two sets of ferromagnetic(FM)/antiferromagnetic(AFM)/ferroelectric(FE) multiferroic heterostructures, including NiFe/NiCoO/glass/PZN-PT (011) and NiFe/FeMn/glass/PZN-PT (011). We designed this experiment to achieve exchange bias tuning along the magnetic easy axis, which is critical for realizing reversible 180° magnetization deterministic switching at zero or small magnetic bias. Strong exchange coupling were established across AFM-FM interfaces, which plays an important role in voltage control of magnetization switching. Through the competition between the E-field induced uniaxial anisotropy in ferromagnetic layer and unidirectional anisotropy in antiferromagnetic layer, the exchange bias was significantly shifted by up to |ΔHex|/Hex = 8% in NiFe/FeMn/glass/PZN-PT (011) and 13% in NiFe/NiCoO/glass/PZN-PT (011). In addition, the square shape of the hysteresis loop, as well as a strong shape tunability of |ΔHex|/Hc = 67.5 ~ 125% in NiFe/FeMn/glass/PZN-PT and 30 ~ 38% in NiFe/NiCoO/glass/PZN-PT were achieved, which lead to a near 180° magnetization switching. Electrical tuning of interfacial exchange coupling in FM/AFM/FE systems paves a new way for realizing magnetoelectric random access memories and other memory technologies.

  3. Electric field induced reversible 180° magnetization switching through tuning of interfacial exchange bias along magnetic easy-axis in multiferroic laminates.

    PubMed

    Xue, Xu; Zhou, Ziyao; Peng, Bin; Zhu, Mingmin; Zhang, Yijun; Ren, Wei; Ren, Tao; Yang, Xi; Nan, Tianxiang; Sun, Nian X; Liu, Ming

    2015-11-18

    E-field control of interfacial exchange coupling and deterministic switching of magnetization have been demonstrated in two sets of ferromagnetic(FM)/antiferromagnetic(AFM)/ferroelectric(FE) multiferroic heterostructures, including NiFe/NiCoO/glass/PZN-PT (011) and NiFe/FeMn/glass/PZN-PT (011). We designed this experiment to achieve exchange bias tuning along the magnetic easy axis, which is critical for realizing reversible 180° magnetization deterministic switching at zero or small magnetic bias. Strong exchange coupling were established across AFM-FM interfaces, which plays an important role in voltage control of magnetization switching. Through the competition between the E-field induced uniaxial anisotropy in ferromagnetic layer and unidirectional anisotropy in antiferromagnetic layer, the exchange bias was significantly shifted by up to |∆Hex|/Hex = 8% in NiFe/FeMn/glass/PZN-PT (011) and 13% in NiFe/NiCoO/glass/PZN-PT (011). In addition, the square shape of the hysteresis loop, as well as a strong shape tunability of |∆Hex|/Hc = 67.5 ~ 125% in NiFe/FeMn/glass/PZN-PT and 30 ~ 38% in NiFe/NiCoO/glass/PZN-PT were achieved, which lead to a near 180° magnetization switching. Electrical tuning of interfacial exchange coupling in FM/AFM/FE systems paves a new way for realizing magnetoelectric random access memories and other memory technologies.

  4. Perpendicular STT_RAM cell in 8 nm technology node using Co1/Ni3(1 1 1)||Gr2||Co1/Ni3(1 1 1) structure as magnetic tunnel junction

    NASA Astrophysics Data System (ADS)

    Varghani, Ali; Peiravi, Ali; Moradi, Farshad

    2018-04-01

    The perpendicular anisotropy Spin-Transfer Torque Random Access Memory (P-STT-RAM) is considered to be a promising candidate for high-density memories. Many distinct advantages of Perpendicular Magnetic Tunnel Junction (P-MTJ) compared to the conventional in-plane MTJ (I-MTJ) such as lower switching current, circular cell shape that facilitates manufacturability in smaller technology nodes, large thermal stability, smaller cell size, and lower dipole field interaction between adjacent cells make it a promising candidate as a universal memory. However, for small MTJ cell sizes, the perpendicular technology requires new materials with high polarization and low damping factor as well as low resistance area product of a P-MTJ in order to avoid a high write voltage as technology is scaled down. A new graphene-based STT-RAM cell for 8 nm technology node that uses high perpendicular magnetic anisotropy cobalt/nickel (Co/Ni) multilayer as magnetic layers is proposed in this paper. The proposed junction benefits from enough Tunneling Magnetoresistance Ratio (TMR), low resistance area product, low write voltage, and low power consumption that make it suitable for 8 nm technology node.

  5. Properties of perpendicular-anisotropy magnetic tunnel junctions fabricated over the bottom electrode contact

    NASA Astrophysics Data System (ADS)

    Miura, Sadahiko; Honjo, Hiroaki; Kinoshita, Keizo; Tokutome, Keiichi; Koike, Hiroaki; Ikeda, Shoji; Endoh, Tetsuo; Ohno, Hideo

    2015-04-01

    Perpendicular-anisotropy magnetic tunnel junctions (MTJs) were prepared on four substrate geometries, i.e., directly on the axis of the bottom electrode contact, directly off the axis of the bottom electrode contact, on the axis of the bottom electrode contact with a polished bottom electrode, and off the axis of the bottom electrode contact with a polished bottom electrode. Electrical shorts were observed for direct on-axis geometry at a certain extent, whereas there were no electrical shorts for the other three geometries. The MR ratio/σR, JC0, and thermal stability factor of the devices for polish on-axis geometry were almost the same as those for polish off-axis geometry. From TEM observations of the polish on-axis device, the interface between the bottom contact and the base electrode was determined to be rough, whereas the MgO barrier layer was determined to be smooth, indicating that the polish process was effective for smooth magnetic tunnel junction fabrication over the bottom contact. MTJs for polish on-axis geometry eliminated the base electrode resistance and increased the magnetoresistance ratio. This technology contributes to the higher density of spin transfer torque magnetic random access memory.

  6. Enhanced interlayer exchange coupling in antiferromagnetically coupled ultrathin (Co70Fe30/Pd) multilayers

    NASA Astrophysics Data System (ADS)

    Meng, Zhaoliang; Qiu, Jinjun; Han, Guchang; Teo, Kie Leong

    2015-12-01

    We report the studies of magnetization reversal and magnetic interlayer coupling in synthetic antiferromagnetic (SAF) [Pd/Co70Fe30]9/Ru(tRu)/Pd(tPd)/[Co70Fe30/Pd]9 structure as functions of inserted Pd layer (tPd) and Ru layer (tRu) thicknesses. We found the exchange coupling field (Hex) and perpendicular magnetic anisotropy (PMA) can be controlled by both the tPd and tRu, The Hex shows a Ruderman-Kittel-Kasuya-Yosida-type oscillatory decay dependence on tRu and a maximum interlayer coupling strength Jex = 0.522 erg/cm2 is achieved at tPd + tRu ≈ 0.8 nm in the as-deposited sample. As it is known that a high post-annealing stability of SAF structure is required for magnetic random access memory applications, the dependence of Hex and PMA on the post-annealing temperature (Ta) is also investigated. We found that both high PMA of the top Co70Fe30/Pd multilayer is maintained and Hex is enhanced with increasing Ta up to 350 °C for tRu > 0.7 nm in our SAF structure.

  7. Tunable properties of spin waves in magnetoelastic {NiFe}/{{Gd}}_{2}{({{MoO}}_{4})}_{3} heterostructure

    NASA Astrophysics Data System (ADS)

    Graczyk, Piotr; Trzaskowska, Aleksandra; Załȩski, Karol; Mróz, Bogusław

    2016-07-01

    Full ferroelastic and simultaneously ferroelectric materials are interesting candidates for applications in devices based on multiferroic heterostructures. They should allow for non-volatile and low-power writing of data bits in magnetoelectric random access memories. Moreover, ferroelasticity, in contrast to piezoelectric material, make magnetic information in ferromagnetic film resistant to external fields. As an example for such a system, we have studied the magnetoelastic interaction between a thin ferromagnetic layer of {{Ni}}85{{Fe}}15 with a full ferroelastic-ferroelectric gadolinium molybdate {{Gd}}2{({{MoO}}4)}3 crystal. We have investigated the influence of {{Gd}}2{({{MoO}}4)}3 spontaneous strain onto magnetic properties of thin ferromagnetic film. Particularly, we have shown by Brillouin spectroscopy, that it is possible to modulate surface spin wave frequency of {{Ni}}85{{Fe}}15 by spontaneous strain of gadolinium molybdate substrate.

  8. High speed magneto-resistive random access memory

    NASA Technical Reports Server (NTRS)

    Wu, Jiin-Chuan (Inventor); Stadler, Henry L. (Inventor); Katti, Romney R. (Inventor)

    1992-01-01

    A high speed read MRAM memory element is configured from a sandwich of magnetizable, ferromagnetic film surrounding a magneto-resistive film which may be ferromagnetic or not. One outer ferromagnetic film has a higher coercive force than the other and therefore remains magnetized in one sense while the other may be switched in sense by a switching magnetic field. The magneto-resistive film is therefore sensitive to the amplitude of the resultant field between the outer ferromagnetic films and may be constructed of a high resistivity, high magneto-resistive material capable of higher sensing currents. This permits higher read voltages and therefore faster read operations. Alternate embodiments with perpendicular anisotropy, and in-plane anisotropy are shown, including an embodiment which uses high permeability guides to direct the closing flux path through the magneto-resistive material. High density, high speed, radiation hard, memory matrices may be constructed from these memory elements.

  9. Conceptual design of a 10 to the 8th power bit magnetic bubble domain mass storage unit and fabrication, test and delivery of a feasibility model

    NASA Technical Reports Server (NTRS)

    1972-01-01

    The conceptual design of a highly reliable 10 to the 8th power-bit bubble domain memory for the space program is described. The memory has random access to blocks of closed-loop shift registers, and utilizes self-contained bubble domain chips with on-chip decoding. Trade-off studies show that the highest reliability and lowest power dissipation is obtained when the memory is organized on a bit-per-chip basis. The final design has 800 bits/register, 128 registers/chip, 16 chips/plane, and 112 planes, of which only seven are activated at a time. A word has 64 data bits +32 checkbits, used in a 16-adjacent code to provide correction of any combination of errors in one plane. 100 KHz maximum rotational frequency keeps power low (equal to or less than, 25 watts) and also allows asynchronous operation. Data rate is 6.4 megabits/sec, access time is 200 msec to an 800-word block and an additional 4 msec (average) to a word. The fabrication and operation are also described for a 64-bit bubble domain memory chip designed to test the concept of on-chip magnetic decoding. Access to one of the chip's four shift registers for the read, write, and clear functions is by means of bubble domain decoders utilizing the interaction between a conductor line and a bubble.

  10. Superparamagnetic perpendicular magnetic tunnel junctions for true random number generators

    NASA Astrophysics Data System (ADS)

    Parks, Bradley; Bapna, Mukund; Igbokwe, Julianne; Almasi, Hamid; Wang, Weigang; Majetich, Sara A.

    2018-05-01

    Superparamagnetic perpendicular magnetic tunnel junctions are fabricated and analyzed for use in random number generators. Time-resolved resistance measurements are used as streams of bits in statistical tests for randomness. Voltage control of the thermal stability enables tuning the average speed of random bit generation up to 70 kHz in a 60 nm diameter device. In its most efficient operating mode, the device generates random bits at an energy cost of 600 fJ/bit. A narrow range of magnetic field tunes the probability of a given state from 0 to 1, offering a means of probabilistic computing.

  11. Process for direct integration of a thin-film silicon p-n junction diode with a magnetic tunnel junction

    DOEpatents

    Toet, Daniel; Sigmon, Thomas W.

    2004-12-07

    A process for direct integration of a thin-film silicon p-n junction diode with a magnetic tunnel junction for use in advanced magnetic random access memory (MRAM) cells for high performance, non-volatile memory arrays. The process is based on pulsed laser processing for the fabrication of vertical polycrystalline silicon electronic device structures, in particular p-n junction diodes, on films of metals deposited onto low temperature-substrates such as ceramics, dielectrics, glass, or polymers. The process preserves underlayers and structures onto which the devices are typically deposited, such as silicon integrated circuits. The process involves the low temperature deposition of at least one layer of silicon, either in an amorphous or a polycrystalline phase on a metal layer. Dopants may be introduced in the silicon film during or after deposition. The film is then irradiated with short pulse laser energy that is efficiently absorbed in the silicon, which results in the crystallization of the film and simultaneously in the activation of the dopants via ultrafast melting and solidification. The silicon film can be patterned either before or after crystallization.

  12. Process For Direct Integration Of A Thin-Film Silicon P-N Junction Diode With A Magnetic Tunnel Junction

    DOEpatents

    Toet, Daniel; Sigmon, Thomas W.

    2005-08-23

    A process for direct integration of a thin-film silicon p-n junction diode with a magnetic tunnel junction for use in advanced magnetic random access memory (MRAM) cells for high performance, non-volatile memory arrays. The process is based on pulsed laser processing for the fabrication of vertical polycrystalline silicon electronic device structures, in particular p-n junction diodes, on films of metals deposited onto low temperature-substrates such as ceramics, dielectrics, glass, or polymers. The process preserves underlayers and structures onto which the devices are typically deposited, such as silicon integrated circuits. The process involves the low temperature deposition of at least one layer of silicon, either in an amorphous or a polycrystalline phase on a metal layer. Dopants may be introduced in the silicon film during or after deposition. The film is then irradiated with short pulse laser energy that is efficiently absorbed in the silicon, which results in the crystallization of the film and simultaneously in the activation of the dopants via ultrafast melting and solidification. The silicon film can be patterned either before or after crystallization.

  13. Process for direct integration of a thin-film silicon p-n junction diode with a magnetic tunnel junction

    DOEpatents

    Toet, Daniel; Sigmon, Thomas W.

    2003-01-01

    A process for direct integration of a thin-film silicon p-n junction diode with a magnetic tunnel junction for use in advanced magnetic random access memory (MRAM) cells for high performance, non-volatile memory arrays. The process is based on pulsed laser processing for the fabrication of vertical polycrystalline silicon electronic device structures, in particular p-n junction diodes, on films of metals deposited onto low temperature-substrates such as ceramics, dielectrics, glass, or polymers. The process preserves underlayers and structures onto which the devices are typically deposited, such as silicon integrated circuits. The process involves the low temperature deposition of at least one layer of silicon, either in an amorphous or a polycrystalline phase on a metal layer. Dopants may be introduced in the silicon film during or after deposition. The film is then irradiated with short pulse laser energy that is efficiently absorbed in the silicon, which results in the crystallization of the film and simultaneously in the activation of the dopants via ultrafast melting and solidification. The silicon film can be patterned either before or after crystallization.

  14. TOPICAL REVIEW: Spin-dependent tunnelling in magnetic tunnel junctions

    NASA Astrophysics Data System (ADS)

    Tsymbal, Evgeny Y.; Mryasov, Oleg N.; LeClair, Patrick R.

    2003-02-01

    The phenomenon of electron tunnelling has been known since the advent of quantum mechanics, but continues to enrich our understanding of many fields of physics, as well as creating sub-fields on its own. Spin-dependent tunnelling (SDT) in magnetic tunnel junctions (MTJs) has recently aroused enormous interest and has developed in a vigorous field of research. The large tunnelling magnetoresistance (TMR) observed in MTJs garnered much attention due to possible applications in non-volatile random-access memories and next-generation magnetic field sensors. This led to a number of fundamental questions regarding the phenomenon of SDT. In this review article we present an overview of this field of research. We discuss various factors that control the spin polarization and magnetoresistance in MTJs. Starting from early experiments on SDT and their interpretation, we consider thereafter recent experiments and models which highlight the role of the electronic structure of the ferromagnets, the insulating layer, and the ferromagnet/insulator interfaces. We also discuss the role of disorder in the barrier and in the ferromagnetic electrodes and their influence on TMR.

  15. Trend of tunnel magnetoresistance and variation in threshold voltage for keeping data load robustness of metal–oxide–semiconductor/magnetic tunnel junction hybrid latches

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Ohsawa, T.; Ikeda, S.; Hanyu, T.

    The robustness of data load of metal–oxide–semiconductor/magnetic tunnel junction (MOS/MTJ) hybrid latches at power-on is examined by using Monte Carlo simulation with the variations in magnetoresistances for MTJs and in threshold voltages for MOSFETs involved in 90 nm technology node. Three differential pair type spin-transfer-torque-magnetic random access memory cells (4T2MTJ, 6T2MTJ, and 8T2MTJ) are compared for their successful data load at power-on. It is found that the 4T2MTJ cell has the largest pass area in the shmoo plot in TMR ratio (tunnel magnetoresistance ratio) and V{sub dd} in which a whole 256 kb cell array can be powered-on successfully. The minimum TMRmore » ratio for the 4T2MTJ in 0.9 V < V{sub dd} < 1.9 V is 140%, while the 6T2MTJ and the 8T2MTJ cells require TMR ratio larger than 170%.« less

  16. Cluster-Glass Phase in Pyrochlore X Y Antiferromagnets with Quenched Disorder

    NASA Astrophysics Data System (ADS)

    Andrade, Eric C.; Hoyos, José A.; Rachel, Stephan; Vojta, Matthias

    2018-03-01

    We study the impact of quenched disorder (random exchange couplings or site dilution) on easy-plane pyrochlore antiferromagnets. In the clean system, order by disorder selects a magnetically ordered state from a classically degenerate manifold. In the presence of randomness, however, different orders can be chosen locally depending on details of the disorder configuration. Using a combination of analytical considerations and classical Monte Carlo simulations, we argue that any long-range-ordered magnetic state is destroyed beyond a critical level of randomness where the system breaks into magnetic domains due to random exchange anisotropies, becoming, therefore, a glass of spin clusters, in accordance with the available experimental data. These random anisotropies originate from off-diagonal exchange couplings in the microscopic Hamiltonian, establishing their relevance to other magnets with strong spin-orbit coupling.

  17. 78 FR 35645 - Certain Static Random Access Memories and Products Containing Same; Commission Determination...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-06-13

    ... INTERNATIONAL TRADE COMMISSION [Investigation No. 337-TA-792] Certain Static Random Access Memories and Products Containing Same; Commission Determination Affirming a Final Initial Determination..., and the sale within the United States after importation of certain static random access memories and...

  18. Portfolio optimization and the random magnet problem

    NASA Astrophysics Data System (ADS)

    Rosenow, B.; Plerou, V.; Gopikrishnan, P.; Stanley, H. E.

    2002-08-01

    Diversification of an investment into independently fluctuating assets reduces its risk. In reality, movements of assets are mutually correlated and therefore knowledge of cross-correlations among asset price movements are of great importance. Our results support the possibility that the problem of finding an investment in stocks which exposes invested funds to a minimum level of risk is analogous to the problem of finding the magnetization of a random magnet. The interactions for this "random magnet problem" are given by the cross-correlation matrix C of stock returns. We find that random matrix theory allows us to make an estimate for C which outperforms the standard estimate in terms of constructing an investment which carries a minimum level of risk.

  19. Demonstration of the Potential of Magnetic Tunnel Junctions for a Universal RAM Technology

    NASA Astrophysics Data System (ADS)

    Gallagher, William J.

    2000-03-01

    Over the past four years, tunnel junctions with magnetic electrodes have emerged as promising devices for future magnetoresistive sensing and for information storage. This talk will review advances in these devices, focusing particularly on the use of magnetic tunnel junctions for magnetic random access memory (MRAM). Exchange-biased versions of magnetic tunnel junctions (MTJs) in particular will be shown to have useful properties for forming magnetic memory storage elements in a novel cross-point architecture. Exchange-biased MTJ elements have been made with areas as small as 0.1 square microns and have shown magnetoresistance values exceeding 40 The potential of exchange-biased MTJs for MRAM has been most seriously explored in a demonstration experiment involving the integration of 0.25 micron CMOS technology with a special magnetic tunnel junction "back end." The magnetic back end is based upon multi-layer magnetic tunnel junction growth technology which was developed using research-scale equipment and one-inch size substrates. For the demonstration, the CMOS wafers processed through two metal layers were cut into one-inch squares for depositions of bottom-pinned exchange-biased magnetic tunnel junctions. The samples were then processed through four additional lithographic levels to complete the circuits. The demonstration focused attention on a number of processing and device issues that were addressed successfully enough that key performance aspects of MTJ MRAM were demonstrated in 1 K bit arrays, including reads and writes in less than 10 ns and nonvolatility. While other key issues remain to be addressed, these results suggest that MTJ MRAM might simultaneously provide much of the functionality now provided separately by SRAM, DRAM, and NVRAM.

  20. 78 FR 25767 - Certain Static Random Access Memories and Products Containing Same; Commission Determination To...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-05-02

    ... INTERNATIONAL TRADE COMMISSION [Investigation No. 337-TA-792] Certain Static Random Access Memories and Products Containing Same; Commission Determination To Review in Part a Final Initial... States after importation of certain static random access memories and products containing the same by...

  1. Data storage technology comparisons

    NASA Technical Reports Server (NTRS)

    Katti, Romney R.

    1990-01-01

    The role of data storage and data storage technology is an integral, though conceptually often underestimated, portion of data processing technology. Data storage is important in the mass storage mode in which generated data is buffered for later use. But data storage technology is also important in the data flow mode when data are manipulated and hence required to flow between databases, datasets and processors. This latter mode is commonly associated with memory hierarchies which support computation. VLSI devices can reasonably be defined as electronic circuit devices such as channel and control electronics as well as highly integrated, solid-state devices that are fabricated using thin film deposition technology. VLSI devices in both capacities play an important role in data storage technology. In addition to random access memories (RAM), read-only memories (ROM), and other silicon-based variations such as PROM's, EPROM's, and EEPROM's, integrated devices find their way into a variety of memory technologies which offer significant performance advantages. These memory technologies include magnetic tape, magnetic disk, magneto-optic disk, and vertical Bloch line memory. In this paper, some comparison between selected technologies will be made to demonstrate why more than one memory technology exists today, based for example on access time and storage density at the active bit and system levels.

  2. Mass storage systems for data transport in the early space station era 1992-1998

    NASA Technical Reports Server (NTRS)

    Carper, Richard (Editor); Dalton, John (Editor); Healey, Mike (Editor); Kempster, Linda (Editor); Martin, John (Editor); Mccaleb, Fred (Editor); Sobieski, Stanley (Editor); Sos, John (Editor)

    1987-01-01

    NASA's Space Station Program will provide a vehicle to deploy an unprecedented number of data producing experiments and operational devices. Peak down link data rates are expected to be in the 500 megabit per second range and the daily data volume could reach 2.4 terabytes. Such startling requirements inspired an internal NASA study to determine if economically viable data storage solutions are likely to be available to support the Ground Data Transport segment of the NASA data system. To derive the requirements for data storage subsystems, several alternative data transport architectures were identified with different degrees of decentralization. Data storage operations at each subsystem were categorized based on access time and retrieval functions, and reduced to the following types of subsystems: First in First out (FIFO) storage, fast random access storage, and slow access with staging. The study showed that industry funded magnetic and optical storage technology has a reasonable probability of meeting these requirements. There are, however, system level issues that need to be addressed in the near term.

  3. Reference-free error estimation for multiple measurement methods.

    PubMed

    Madan, Hennadii; Pernuš, Franjo; Špiclin, Žiga

    2018-01-01

    We present a computational framework to select the most accurate and precise method of measurement of a certain quantity, when there is no access to the true value of the measurand. A typical use case is when several image analysis methods are applied to measure the value of a particular quantitative imaging biomarker from the same images. The accuracy of each measurement method is characterized by systematic error (bias), which is modeled as a polynomial in true values of measurand, and the precision as random error modeled with a Gaussian random variable. In contrast to previous works, the random errors are modeled jointly across all methods, thereby enabling the framework to analyze measurement methods based on similar principles, which may have correlated random errors. Furthermore, the posterior distribution of the error model parameters is estimated from samples obtained by Markov chain Monte-Carlo and analyzed to estimate the parameter values and the unknown true values of the measurand. The framework was validated on six synthetic and one clinical dataset containing measurements of total lesion load, a biomarker of neurodegenerative diseases, which was obtained with four automatic methods by analyzing brain magnetic resonance images. The estimates of bias and random error were in a good agreement with the corresponding least squares regression estimates against a reference.

  4. Random access with adaptive packet aggregation in LTE/LTE-A.

    PubMed

    Zhou, Kaijie; Nikaein, Navid

    While random access presents a promising solution for efficient uplink channel access, the preamble collision rate can significantly increase when massive number of devices simultaneously access the channel. To address this issue and improve the reliability of the random access, an adaptive packet aggregation method is proposed. With the proposed method, a device does not trigger a random access for every single packet. Instead, it starts a random access when the number of aggregated packets reaches a given threshold. This method reduces the packet collision rate at the expense of an extra latency, which is used to accumulate multiple packets into a single transmission unit. Therefore, the tradeoff between packet loss rate and channel access latency has to be carefully selected. We use semi-Markov model to derive the packet loss rate and channel access latency as functions of packet aggregation number. Hence, the optimal amount of aggregated packets can be found, which keeps the loss rate below the desired value while minimizing the access latency. We also apply for the idea of packet aggregation for power saving, where a device aggregates as many packets as possible until the latency constraint is reached. Simulations are carried out to evaluate our methods. We find that the packet loss rate and/or power consumption are significantly reduced with the proposed method.

  5. Magnetic cluster expansion model for random and ordered magnetic face-centered cubic Fe-Ni-Cr alloys

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Lavrentiev, M. Yu., E-mail: Mikhail.Lavrentiev@ukaea.uk; Nguyen-Manh, D.; Dudarev, S. L.

    A Magnetic Cluster Expansion model for ternary face-centered cubic Fe-Ni-Cr alloys has been developed, using DFT data spanning binary and ternary alloy configurations. Using this Magnetic Cluster Expansion model Hamiltonian, we perform Monte Carlo simulations and explore magnetic structures of alloys over the entire range of compositions, considering both random and ordered alloy structures. In random alloys, the removal of magnetic collinearity constraint reduces the total magnetic moment but does not affect the predicted range of compositions where the alloys adopt low-temperature ferromagnetic configurations. During alloying of ordered fcc Fe-Ni compounds with Cr, chromium atoms tend to replace nickel rathermore » than iron atoms. Replacement of Ni by Cr in ordered alloys with high iron content increases the Curie temperature of the alloys. This can be explained by strong antiferromagnetic Fe-Cr coupling, similar to that found in bcc Fe-Cr solutions, where the Curie temperature increase, predicted by simulations as a function of Cr concentration, is confirmed by experimental observations. In random alloys, both magnetization and the Curie temperature decrease abruptly with increasing chromium content, in agreement with experiment.« less

  6. 76 FR 2336 - Dynamic Random Access Memory Semiconductors From the Republic of Korea: Final Results of...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-01-13

    ... DEPARTMENT OF COMMERCE International Trade Administration [C-580-851] Dynamic Random Access Memory... administrative review of the countervailing duty order on dynamic random access memory semiconductors from the... following events have occurred since the publication of the preliminary results of this review. See Dynamic...

  7. ATLAS, an integrated structural analysis and design system. Volume 4: Random access file catalog

    NASA Technical Reports Server (NTRS)

    Gray, F. P., Jr. (Editor)

    1979-01-01

    A complete catalog is presented for the random access files used by the ATLAS integrated structural analysis and design system. ATLAS consists of several technical computation modules which output data matrices to corresponding random access file. A description of the matrices written on these files is contained herein.

  8. Origin of interfacial perpendicular magnetic anisotropy in MgO/CoFe/metallic capping layer structures

    NASA Astrophysics Data System (ADS)

    Peng, Shouzhong; Wang, Mengxing; Yang, Hongxin; Zeng, Lang; Nan, Jiang; Zhou, Jiaqi; Zhang, Youguang; Hallal, Ali; Chshiev, Mairbek; Wang, Kang L.; Zhang, Qianfan; Zhao, Weisheng

    2015-12-01

    Spin-transfer-torque magnetic random access memory (STT-MRAM) attracts extensive attentions due to its non-volatility, high density and low power consumption. The core device in STT-MRAM is CoFeB/MgO-based magnetic tunnel junction (MTJ), which possesses a high tunnel magnetoresistance ratio as well as a large value of perpendicular magnetic anisotropy (PMA). It has been experimentally proven that a capping layer coating on CoFeB layer is essential to obtain a strong PMA. However, the physical mechanism of such effect remains unclear. In this paper, we investigate the origin of the PMA in MgO/CoFe/metallic capping layer structures by using a first-principles computation scheme. The trend of PMA variation with different capping materials agrees well with experimental results. We find that interfacial PMA in the three-layer structures comes from both the MgO/CoFe and CoFe/capping layer interfaces, which can be analyzed separately. Furthermore, the PMAs in the CoFe/capping layer interfaces are analyzed through resolving the magnetic anisotropy energy by layer and orbital. The variation of PMA with different capping materials is attributed to the different hybridizations of both d and p orbitals via spin-orbit coupling. This work can significantly benefit the research and development of nanoscale STT-MRAM.

  9. Stability phase diagram of a perpendicular magnetic tunnel junction in noncollinear geometry

    NASA Astrophysics Data System (ADS)

    Strelkov, N.; Timopheev, A.; Sousa, R. C.; Chshiev, M.; Buda-Prejbeanu, L. D.; Dieny, B.

    2017-05-01

    Experimental measurements performed on MgO-based perpendicular magnetic tunnel junctions show a strong dependence of the stability voltage-field diagrams as a function of the direction of the magnetic field with respect to the plane of the sample. When the magnetic field is applied in-plane, systematic nonlinear phase boundaries are observed for various lateral sizes. The simulation results based on the phenomenological Landau-Lifshitz-Gilbert equation including the in-plane and out-of-plane spin transfer torques are consistent with the measurements if a second-order anisotropy contribution is considered. Furthermore, performing the stability analysis in linear approximation allowed us to analytically extract the critical switching voltage at zero temperature in the presence of an in-plane field. This study indicates that in the noncollinear geometry investigations are suitable to detect the presence of the second-order term in the anisotropy. Such higher order anisotropy term can yield an easy-cone anisotropy which reduces the thermal stability factor but allows for more reproducible spin transfer torque switching due to a reduced stochasticity of the switching. As a result, the energy per write event decreases much faster than the thermal stability factor as the second-order anisotropy becomes more negative. Easy-cone anisotropy can be useful for fast-switching spin transfer torque magnetic random access memories provided the thermal stability can be maintained above the required value for a given memory specification.

  10. Origin of interfacial perpendicular magnetic anisotropy in MgO/CoFe/metallic capping layer structures.

    PubMed

    Peng, Shouzhong; Wang, Mengxing; Yang, Hongxin; Zeng, Lang; Nan, Jiang; Zhou, Jiaqi; Zhang, Youguang; Hallal, Ali; Chshiev, Mairbek; Wang, Kang L; Zhang, Qianfan; Zhao, Weisheng

    2015-12-11

    Spin-transfer-torque magnetic random access memory (STT-MRAM) attracts extensive attentions due to its non-volatility, high density and low power consumption. The core device in STT-MRAM is CoFeB/MgO-based magnetic tunnel junction (MTJ), which possesses a high tunnel magnetoresistance ratio as well as a large value of perpendicular magnetic anisotropy (PMA). It has been experimentally proven that a capping layer coating on CoFeB layer is essential to obtain a strong PMA. However, the physical mechanism of such effect remains unclear. In this paper, we investigate the origin of the PMA in MgO/CoFe/metallic capping layer structures by using a first-principles computation scheme. The trend of PMA variation with different capping materials agrees well with experimental results. We find that interfacial PMA in the three-layer structures comes from both the MgO/CoFe and CoFe/capping layer interfaces, which can be analyzed separately. Furthermore, the PMAs in the CoFe/capping layer interfaces are analyzed through resolving the magnetic anisotropy energy by layer and orbital. The variation of PMA with different capping materials is attributed to the different hybridizations of both d and p orbitals via spin-orbit coupling. This work can significantly benefit the research and development of nanoscale STT-MRAM.

  11. Study of magnetization switching in coupled magnetic nanostructured systems

    NASA Astrophysics Data System (ADS)

    Radu, Cosmin

    A study of magnetization dynamics experiments in nanostructured materials using the rf susceptibility tunnel diode oscillator (TDO) method is presented along with a extensive theoretical analysis. An original, computer controlled experimental setup that measures the change in susceptibility with the variation in external magnetic field and sample temperature was constructed. The TDO-based experiment design and construction is explained in detail, showing all the elements of originality. This experimental technique has proven reliable for characterizing samples with uncoupled magnetic structure and various magnetic anisotropies like: CrO2, FeCo/IrMn and Co/SiO2 thin films. The TDO was subsequently used to explore the magnetization switching in coupled magnetic systems, like synthetic antiferromagnet (SAF) structures. Magnetoresistive random access memory (MRAM) is an important example of devices where the use of SAF structure is essential. To support the understanding of the SAF magnetic behavior, its configuration and application are reviewed and more details are provided in an appendix. Current problems in increasing the scalability and decreasing the error rate of MRAM devices are closely connected to the switching properties of the SAF structures. Several theoretical studies that were devoted to the understanding of the concepts of SAF critical curve are reviewed. As one can notice, there was no experimental determination of SAF critical curve, due to the difficulties in characterizing a magnetic coupled structure. Depending of the coupling strength between the two ferromagnetic layers, on the SAF critical curve one distinguishes several new features, inexistent in the case of uncoupled systems. Knowing the configuration of the SAF critical curve is of great importance in order to control its switching characteristics. For the first time a method of experimentally recording the critical curve for SAF is proposed in this work. In order to overcome technological limitations, a new way of recording the critical curve by using an additional magnetic bias field was explored. Keywords: magnetization dynamics, magnetic susceptibility, tunnel diode oscillator, critical curve, synthetic antiferromagnet, coupled magnetic structures, MRAM.

  12. 75 FR 44283 - In the Matter of Certain Dynamic Random Access Memory Semiconductors and Products Containing Same...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-07-28

    ... Random Access Memory Semiconductors and Products Containing Same, Including Memory Modules; Notice of a... importation of certain dynamic random access memory semiconductors and products containing same, including memory modules, by reason of infringement of certain claims of U.S. Patent Nos. 5,480,051; 5,422,309; 5...

  13. Structural and magnetic characterization of Fe2CrSi Heusler alloy nanoparticles as spin injectors and spin based sensors

    NASA Astrophysics Data System (ADS)

    Saravanan, G.; Asvini, V.; Kalaiezhily, R. K.; Parveen, I. Mubeena; Ravichandran, K.

    2018-05-01

    Half-metallic ferromagnetic [HMF] nanoparticles are of considerable interest in spintronics applications due to their potential use as a highly spin polarized current source. HMF exhibits a semiconductor in one spin band at the Fermi level Ef and at the other spin band they poses strong metallic nature which shows 100 % spin polarization at Ef. Fe based full Heusler alloys are primary interest due to high Curie temperature. Fe2CrSi Heusler alloys are synthesized using metallic powders of Fe, Cr and Si by mechanical alloying method. X-Ray diffractions studies were performed to analyze the structural details of Fe2CrSi nanoparticles with High resolution scanning electron microscope (HRSEM) studies for the morphological details of nanoparticles and magnetic properties were studied using Vibrating sample magnetometer (VSM). XRD Data analysis conforms the Heusler alloy phase showing the existence of L21 structure. Magnetic properties are measured for synthesized samples exhibiting a soft magnetic property possessing low coercivity (HC = 60.5 Oe) and saturation magnetic moment of Fe2CrSi is 3.16 µB, which is significantly higher than the ideal value of 2 µB from the Slater-Pauling rule due to room temperature measurement. The change in magnetic properties are half-metallic nature of Fe2CrSi is due to the shift of the Fermi level with respect to the gap were can be used as spin sensors and spin injectors in magnetic random access memories and other spin dependent devices.

  14. Distributed magnetic field positioning system using code division multiple access

    NASA Technical Reports Server (NTRS)

    Prigge, Eric A. (Inventor)

    2003-01-01

    An apparatus and methods for a magnetic field positioning system use a fundamentally different, and advantageous, signal structure and multiple access method, known as Code Division Multiple Access (CDMA). This signal architecture, when combined with processing methods, leads to advantages over the existing technologies, especially when applied to a system with a large number of magnetic field generators (beacons). Beacons at known positions generate coded magnetic fields, and a magnetic sensor measures a sum field and decomposes it into component fields to determine the sensor position and orientation. The apparatus and methods can have a large `building-sized` coverage area. The system allows for numerous beacons to be distributed throughout an area at a number of different locations. A method to estimate position and attitude, with no prior knowledge, uses dipole fields produced by these beacons in different locations.

  15. Spin dynamics of random Ising chain in coexisting transverse and longitudinal magnetic fields

    NASA Astrophysics Data System (ADS)

    Liu, Zhong-Qiang; Jiang, Su-Rong; Kong, Xiang-Mu; Xu, Yu-Liang

    2017-05-01

    The dynamics of the random Ising spin chain in coexisting transverse and longitudinal magnetic fields is studied by the recursion method. Both the spin autocorrelation function and its spectral density are investigated by numerical calculations. It is found that system's dynamical behaviors depend on the deviation σJ of the random exchange coupling between nearest-neighbor spins and the ratio rlt of the longitudinal and the transverse fields: (i) For rlt = 0, the system undergoes two crossovers from N independent spins precessing about the transverse magnetic field to a collective-mode behavior, and then to a central-peak behavior as σJ increases. (ii) For rlt ≠ 0, the system may exhibit a coexistence behavior of a collective-mode one and a central-peak one. When σJ is small (or large enough), system undergoes a crossover from a coexistence behavior (or a disordered behavior) to a central-peak behavior as rlt increases. (iii) Increasing σJ depresses effects of both the transverse and the longitudinal magnetic fields. (iv) Quantum random Ising chain in coexisting magnetic fields may exhibit under-damping and critical-damping characteristics simultaneously. These results indicate that changing the external magnetic fields may control and manipulate the dynamics of the random Ising chain.

  16. Jupiter Environment Tool

    NASA Technical Reports Server (NTRS)

    Sturm, Erick J.; Monahue, Kenneth M.; Biehl, James P.; Kokorowski, Michael; Ngalande, Cedrick,; Boedeker, Jordan

    2012-01-01

    The Jupiter Environment Tool (JET) is a custom UI plug-in for STK that provides an interface to Jupiter environment models for visualization and analysis. Users can visualize the different magnetic field models of Jupiter through various rendering methods, which are fully integrated within STK s 3D Window. This allows users to take snapshots and make animations of their scenarios with magnetic field visualizations. Analytical data can be accessed in the form of custom vectors. Given these custom vectors, users have access to magnetic field data in custom reports, graphs, access constraints, coverage analysis, and anywhere else vectors are used within STK.

  17. Large-eddy simulation, atmospheric measurement and inverse modeling of greenhouse gas emissions at local spatial scales

    NASA Astrophysics Data System (ADS)

    Nottrott, Anders Andelman

    Multiferroic materials and devices have attracted intensified interests due to the demonstrated strong magnetoelectric coupling in new multiferroic materials, artificial multiferroic heterostructures and devices with unique functionalities and superior performance characteristics. This offers great opportunities for achieving compact, fast, energy-efficient and voltage tunable spintronic devices. In traditional magnetic materials based magnetic random access memories (MRAM) devices, the binary information is stored as magnetization. The high coercivity of the ferromagnetic media requires large magnetic fields for switching the magnetic states thus consuming large amount of energy. In modern MRAM information writing process, spin-torque technique is utilized for minimizing the large energy for generating magnetic field by passing through a spin-polarized current directly to the magnets. However, both methods still need large current/current density to toggle the magnetic bits which consume large amount of energy. With the presence of multiferroic or magnetoelectric materials, spin is controlled by electric field which opens new opportunities for power-efficient voltage control of magnetization in spintronic devices leading to magnetoelectric random access memories (MERAM) with ultra-low energy consumption. However, state of the art multiferroic materials still have difficulty of realizing nonvolatile 180° magnetization reversal, which is desired in realizing MERAM. In a strain-mediated multiferroic system, the typical modification of the magnetism of ferromagnetic phase as a function of bipolar electric field shows a "butterfly" like behavior. This is due to the linear piezoelectricity of ferroelectric phase which has a "butterfly" like piezostrain as a function of electric field curve resulting from ferroelectric domain wall switching. In this case, the magnetization state is volatile because of the vanishing of the piezostrain at zero electric field. However, the non-volatile switching of magnetization would be more promising for information storage or MERAM devices with lower energy consumption and the magnetic state can be further controlled by voltage impulse. In this work, we first study the equivalent of direct and converse magnetoelectric effects. The resonant direct and converse magnetoelectric (ME) effects have been investigated experimentally and theoretically in FeGa/PZT/FeGa sandwich laminate composites. The frequency responses of direct and converse magnetoelectric effects were measured under the same electric and magnetic bias conditions. The resonant direct ME effect (DME) occurs at an antiresonance frequency, while resonant converse ME effect (CME) occurs at a resonance frequency. The antiresonance and resonance frequencies have close but different values under identical bias conditions. The magnitudes of resonant effective ME coefficients for direct and converse ME effects are also not equal. Based on different sets of constitutive equations of the materials for DME and CME, a new model was developed to describe the frequency response of DME and CME in laminate composite, which was in good agreement with the experimental results. Inequivalence of resonant ME effects is ascribed to the different mechanical and electrical boundary conditions for DME and CME. On the other hand, similar bias E and H field dependence was observed for both DME and CME resonance frequencies and resonant coefficients, indicating consistency between DME and CME effects. In the study of the frequency response of DME and CME, the linear piezoelectric effect is used. However, this linear piezoelectric effect in converse magnetoelectric coupling would lead to "butter-fly" like magnetization vs. electric field curve which leads to a "volatile" behavior in magnetic memory system. In the presented study, a unique ferroelastic switching pathway in ferroelectric substrates is utilized to produce two distinct, reversible and stable lattice strain states which leads to the establish of two stable magnetization states of the ferromagnetic thin film. In this process, instead of complete 180° ferromagnetic domain switching, 71°/109° ferroelastic domain wall switching is involved, where the electric polarization is switching between in-plane and out-of-plane direction. A voltage impulse induced reversible bistable magnetization switching in FeGaB/lead zirconate titanate (PZT) multiferroic heterostructures at room temperature is first demonstrated. Two reversible and stable voltage-impulse induced mechanical strain states were obtained in the PZT by applying an electric field impulse with its amplitude smaller than the electric coercive field, which led to reversible voltage impulse induced bistable magnetization switching. Direct and converse magnetoelectric effects are carefully quantified.

  18. Reliable low-power control of ultrafast vortex-core switching with the selectivity in an array of vortex states by in-plane circular-rotational magnetic fields and spin-polarized currents

    NASA Astrophysics Data System (ADS)

    Kim, Sang-Koog; Lee, Ki-Suk; Yu, Young-Sang; Choi, Youn-Seok

    2008-01-01

    The authors investigated the technological utility of counterclockwise (CCW) and clockwise (CW) circular-rotating fields (HCCW and HCW) and spin-polarized currents with an angular frequency ωH close to the vortex eigenfrequency ωD, for the reliable, low-power, and selective switching of the bistate magnetization (M) orientations of a vortex core (VC) in an array of soft magnetic nanoelements. CCW and CW circular gyrotropic motions in response to HCCW and HCW, respectively, show remarkably contrasting resonant behaviors, (i.e., extremely large-amplitude resonance versus small-amplitude nonresonance), depending on the M orientation of a given VC. Owing to this asymmetric resonance characteristics, the HCCW(HCW) with ωH˜ωD can be used to effectively switch only the up (down) core to its downward (upward) M orientation, selectively, by sufficiently low field (˜10Oe) and current density (˜107A/cm2). This work provides a reliable, low power, effective means of information storage, information recording, and information readout in vortex-based random access memory, simply called VRAM.

  19. Giant and universal magnetoelectric coupling in soft materials and concomitant ramifications for materials science and biology

    NASA Astrophysics Data System (ADS)

    Liu, Liping; Sharma, Pradeep

    2013-10-01

    Magnetoelectric coupling—the ability of a material to magnetize upon application of an electric field and, conversely, to polarize under the action of a magnetic field—is rare and restricted to a rather small set of exotic hard crystalline materials. Intense research activity has recently ensued on materials development, fundamental scientific issues, and applications related to this phenomenon. This tantalizing property, if present in adequate strength at room temperature, can be used to pave the way for next-generation memory devices such as miniature magnetic random access memories and multiple state memory bits, sensors, energy harvesting, spintronics, among others. In this Rapid Communication, we prove the existence of an overlooked strain mediated nonlinear mechanism that can be used to universally induce the giant magnetoelectric effect in all (sufficiently) soft dielectric materials. For soft polymer foams—which, for instance, may be used in stretchable electronics—we predict room-temperature magnetoelectric coefficients that are comparable to the best known (hard) composite materials created. We also argue, based on a simple quantitative model, that magnetoreception in some biological contexts (e.g., birds) most likely utilizes this very mechanism.

  20. Possible disruption of remote viewing by complex weak magnetic fields around the stimulus site and the possibility of accessing real phase space: a pilot study.

    PubMed

    Koren, S A; Persinger, M A

    2002-12-01

    In 2002 Persinger, Roll, Tiller, Koren, and Cook considered whether there are physical processes by which recondite information exists within the space and time of objects or events. The stimuli that compose this information might be directly detected within the whole brain without being processed by the typical sensory modalities. We tested the artist Ingo Swann who can reliably draw and describe randomly selected photographs sealed in envelopes in another room. In the present experiment the photographs were immersed continuously in repeated presentations (5 times per sec.) of one of two types of computer-generated complex magnetic field patterns whose intensities were less than 20 nT over most of the area. WINDOWS-generated but not DOS-generated patterns were associated with a marked decrease in Mr. Swann's accuracy. Whereas the DOS software generated exactly the same pattern, WINDOWS software phase-modulated the actual wave form resulting in an infinite bandwidth and complexity. We suggest that information obtained by processes attributed to "paranormal" phenomena have physical correlates that can be masked by weak, infinitely variable magnetic fields.

  1. Perpendicular magnetic tunnel junctions with Mn-modified ultrathin MnGa layer

    NASA Astrophysics Data System (ADS)

    Suzuki, K. Z.; Miura, Y.; Ranjbar, R.; Bainsla, L.; Ono, A.; Sasaki, Y.; Mizukami, S.

    2018-02-01

    Perpendicular magnetic tunnel junctions (p-MTJs) with a MgO barrier and a 1-nm-thick MnGa electrode were investigated by inserting several monolayers (MLs) of Mn. The tunnel magnetoresistance (TMR) ratio systematically increased when increasing the Mn layer thickness with a maximum of 18 (38.4)% at 300 (5) K for a Mn layer thickness of 0.6-0.8 nm. This ratio is five times higher compared to that without the Mn layer. The perpendicular magnetic anisotropy (PMA) field and the PMA constant of the ultrathin MnGa layer also increased up to 62-90 kOe and 6.2-11.3 Merg/cm3, respectively, with an increase in the Mn interlayer thickness, even for the ultrathin regime of the MnGa layer. For p-MTJs showing a high TMR and PMA, electron microscopy indicated the presence of 3-4 MLs of Mn at the MnGa/MgO interface; thus, the Mn modification enhanced the TMR as well as improved the PMA. This may be a promising finding to develop a Mn-based free layer for spin-transfer-torque devices for high-recording-density magnetoresistive random access memory and a sub-THz oscillator/detector.

  2. Mass storage technology in networks

    NASA Astrophysics Data System (ADS)

    Ishii, Katsunori; Takeda, Toru; Itao, Kiyoshi; Kaneko, Reizo

    1990-08-01

    Trends and features of mass storage subsystems in network are surveyed and their key technologies spotlighted. Storage subsystems are becoming increasingly important in new network systems in which communications and data processing are systematically combined. These systems require a new class of high-performance mass-information storage in order to effectively utilize their processing power. The requirements of high transfer rates, high transactional rates and large storage capacities, coupled with high functionality, fault tolerance and flexibility in configuration, are major challenges in storage subsystems. Recent progress in optical disk technology has resulted in improved performance of on-line external memories to optical disk drives, which are competing with mid-range magnetic disks. Optical disks are more effective than magnetic disks in using low-traffic random-access file storing multimedia data that requires large capacity, such as in archive use and in information distribution use by ROM disks. Finally, it demonstrates image coded document file servers for local area network use that employ 130mm rewritable magneto-optical disk subsystems.

  3. 230% room-temperature magnetoresistance in CoFeB /MgO/CoFeB magnetic tunnel junctions

    NASA Astrophysics Data System (ADS)

    Djayaprawira, David D.; Tsunekawa, Koji; Nagai, Motonobu; Maehara, Hiroki; Yamagata, Shinji; Watanabe, Naoki; Yuasa, Shinji; Suzuki, Yoshishige; Ando, Koji

    2005-02-01

    Magnetoresistance (MR) ratio up to 230% at room temperature (294% at 20 K) has been observed in spin-valve-type magnetic tunnel junctions (MTJs) using MgO tunnel barrier layer fabricated on thermally oxidized Si substrates. We found that such a high MR ratio can be obtained when the MgO barrier layer was sandwiched with amorphous CoFeB ferromagnetic electrodes. Microstructure analysis revealed that the MgO layer with (001) fiber texture was realized when the MgO layer was grown on amorphous CoFeB rather than on polycrystalline CoFe. Since there have been no theoretical studies on the MTJs with a crystalline tunnel barrier and amorphous electrodes, the detailed mechanism of the huge tunneling MR effect observed in this study is not clear at the present stage. Nevertheless, the present work is of paramount importance in realizing high-density magnetoresistive random access memory and read head for ultra high-density hard-disk drives into practical use.

  4. A spin transfer torque magnetoresistance random access memory-based high-density and ultralow-power associative memory for fully data-adaptive nearest neighbor search with current-mode similarity evaluation and time-domain minimum searching

    NASA Astrophysics Data System (ADS)

    Ma, Yitao; Miura, Sadahiko; Honjo, Hiroaki; Ikeda, Shoji; Hanyu, Takahiro; Ohno, Hideo; Endoh, Tetsuo

    2017-04-01

    A high-density nonvolatile associative memory (NV-AM) based on spin transfer torque magnetoresistive random access memory (STT-MRAM), which achieves highly concurrent and ultralow-power nearest neighbor search with full adaptivity of the template data format, has been proposed and fabricated using the 90 nm CMOS/70 nm perpendicular-magnetic-tunnel-junction hybrid process. A truly compact current-mode circuitry is developed to realize flexibly controllable and high-parallel similarity evaluation, which makes the NV-AM adaptable to any dimensionality and component-bit of template data. A compact dual-stage time-domain minimum searching circuit is also developed, which can freely extend the system for more template data by connecting multiple NM-AM cores without additional circuits for integrated processing. Both the embedded STT-MRAM module and the computing circuit modules in this NV-AM chip are synchronously power-gated to completely eliminate standby power and maximally reduce operation power by only activating the currently accessed circuit blocks. The operations of a prototype chip at 40 MHz are demonstrated by measurement. The average operation power is only 130 µW, and the circuit density is less than 11 µm2/bit. Compared with the latest conventional works in both volatile and nonvolatile approaches, more than 31.3% circuit area reductions and 99.2% power improvements are achieved, respectively. Further power performance analyses are discussed, which verify the special superiority of the proposed NV-AM in low-power and large-memory-based VLSIs.

  5. Spin-wave utilization in a quantum computer

    NASA Astrophysics Data System (ADS)

    Khitun, A.; Ostroumov, R.; Wang, K. L.

    2001-12-01

    We propose a quantum computer scheme using spin waves for quantum-information exchange. We demonstrate that spin waves in the antiferromagnetic layer grown on silicon may be used to perform single-qubit unitary transformations together with two-qubit operations during the cycle of computation. The most attractive feature of the proposed scheme is the possibility of random access to any qubit and, consequently, the ability to recognize two qubit gates between any two distant qubits. Also, spin waves allow us to eliminate the use of a strong external magnetic field and microwave pulses. By estimate, the proposed scheme has as high as 104 ratio between quantum system coherence time and the time of a single computational step.

  6. 15 CFR Appendix E to Subpart M of... - Motorized Personal Watercraft Zones and Access Routes Within the Sanctuary

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... access route southwest along a bearing of approximately 196° true (180° magnetic) to the red and white...° magnetic) to the red and white bell buoy at the eastern boundary of Zone Three bounded by: Point ID No...° true (0° magnetic) to the southern boundary of Zone Four bounded by: Point ID No. Latitude Longitude 1...

  7. A graphite based STT-RAM cell with reduction in switching current

    NASA Astrophysics Data System (ADS)

    Varghani, Ali; Peiravi, Ali

    2015-10-01

    Spin Transfer Torque Random Access Memory (STT-RAM) is a serious candidate for "universal memory" because of its non-volatility, fast access time, high density, good scalability, high endurance and relatively low power dissipation. However, problems with low write speed and large write current are important existing challenges in STT-RAM design and there is a tradeoff between them and data retention time. In this study, a novel STT-RAM cell structure which uses perfect graphite based Magnetic Tunnel Junction (MTJ) is proposed. First, the cross-section of the structure is selected to be an ellipse of 45 nm and 180 nm dimensions and a six-layer graphite is used as tunnel barrier. By passing a lateral current with a short pulse width (before applying STT current and independent of it) through four middle graphene layers of the tunnel barrier, a 27% reduction in the amplitude of the switching current (for fast switching time of 2 ns) or a 58% reduction in its pulse width is achieved without any reduction in data retention time. Finally, the effect of downscaling of technology on the proposed structure is evaluated. A reduction of 31.6% and 9% in switching current is achieved for 90 and 22 nm cell width respectively by passing sufficient current (100 μA with 0.1 ns pulse width) through the tunnel barrier. Simulations are done using Object Oriented Micro Magnetic Framework (OOMMF).

  8. [A magnetic therapy apparatus with an adaptable electromagnetic spectrum for the treatment of prostatitis and gynecopathies].

    PubMed

    Kuz'min, A A; Meshkovskiĭ, D V; Filist, S A

    2008-01-01

    Problems of engineering and algorithm development of magnetic therapy apparatuses with pseudo-random radiation spectrum within the audio range for treatment of prostatitis and gynecopathies are considered. A typical design based on a PIC 16F microcontroller is suggested. It includes a keyboard, LCD indicator, audio amplifier, inducer, and software units. The problem of pseudo-random signal generation within the audio range is considered. A series of rectangular pulses is generated on a random-length interval on the basis of a three-component random vector. This series provides the required spectral characteristics of the therapeutic magnetic field and their adaptation to the therapeutic conditions and individual features of the patient.

  9. Design of high-throughput and low-power true random number generator utilizing perpendicularly magnetized voltage-controlled magnetic tunnel junction

    NASA Astrophysics Data System (ADS)

    Lee, Hochul; Ebrahimi, Farbod; Amiri, Pedram Khalili; Wang, Kang L.

    2017-05-01

    A true random number generator based on perpendicularly magnetized voltage-controlled magnetic tunnel junction devices (MRNG) is presented. Unlike MTJs used in memory applications where a stable bit is needed to store information, in this work, the MTJ is intentionally designed with small perpendicular magnetic anisotropy (PMA). This allows one to take advantage of the thermally activated fluctuations of its free layer as a stochastic noise source. Furthermore, we take advantage of the voltage dependence of anisotropy to temporarily change the MTJ state into an unstable state when a voltage is applied. Since the MTJ has two energetically stable states, the final state is randomly chosen by thermal fluctuation. The voltage controlled magnetic anisotropy (VCMA) effect is used to generate the metastable state of the MTJ by lowering its energy barrier. The proposed MRNG achieves a high throughput (32 Gbps) by implementing a 64 ×64 MTJ array into CMOS circuits and executing operations in a parallel manner. Furthermore, the circuit consumes very low energy to generate a random bit (31.5 fJ/bit) due to the high energy efficiency of the voltage-controlled MTJ switching.

  10. Dependency of anti-ferro-magnetic coupling strength on Ru spacer thickness of [Co/Pd]{sub n}-synthetic-anti-ferro-magnetic layer in perpendicular magnetic-tunnel-junctions fabricated on 12-inch TiN electrode wafer

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Chae, Kyo-Suk; Samsung Electronics Co., Ltd., San #16 Banwol-dong, Hwasung-City, Gyeonggi-Do 445-701; Shim, Tae-Hun

    We investigated the Ru spacer-thickness effect on the anti-ferro-magnetic coupling strength (J{sub ex}) of a [Co/Pd]{sub n}-synthetic-anti-ferro-magnetic layer fabricated with Co{sub 2}Fe{sub 6}B{sub 2}/MgO based perpendicular-magnetic-tunneling-junction spin-valves on 12-in. TiN electrode wafers. J{sub ex} peaked at a certain Ru spacer-thickness: specifically, a J{sub ex} of 0.78 erg/cm{sup 2} at 0.6 nm, satisfying the J{sub ex} criteria for realizing the mass production of terra-bit-level perpendicular-spin-transfer-torque magnetic-random-access-memory. Otherwise, J{sub ex} rapidly degraded when the Ru spacer-thickness was less than or higher than 0.6 nm. As a result, the allowable Ru thickness variation should be controlled less than 0.12 nm to satisfy the J{sub ex} criteria. However,more » the Ru spacer-thickness did not influence the tunneling-magneto-resistance (TMR) and resistance-area (RA) of the perpendicular-magnetic-tunneling-junction (p-MTJ) spin-valves since the Ru spacer in the synthetic-anti-ferro-magnetic layer mainly affects the anti-ferro-magnetic coupling efficiency rather than the crystalline linearity of the Co{sub 2}Fe{sub 6}B{sub 2} free layer/MgO tunneling barrier/Co{sub 2}Fe{sub 6}B{sub 2} pinned layer, although Co{sub 2}Fe{sub 6}B{sub 2}/MgO based p-MTJ spin-valves ex-situ annealed at 275 °C achieved a TMR of ∼70% at a RA of ∼20 Ω μm{sup 2}.« less

  11. Random-access algorithms for multiuser computer communication networks. Doctoral thesis, 1 September 1986-31 August 1988

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Papantoni-Kazakos, P.; Paterakis, M.

    1988-07-01

    For many communication applications with time constraints (e.g., transmission of packetized voice messages), a critical performance measure is the percentage of messages transmitted within a given amount of time after their generation at the transmitting station. This report presents a random-access algorithm (RAA) suitable for time-constrained applications. Performance analysis demonstrates that significant message-delay improvement is attained at the expense of minimal traffic loss. Also considered is the case of noisy channels. The noise effect appears at erroneously observed channel feedback. Error sensitivity analysis shows that the proposed random-access algorithm is insensitive to feedback channel errors. Window Random-Access Algorithms (RAAs) aremore » considered next. These algorithms constitute an important subclass of Multiple-Access Algorithms (MAAs); they are distributive, and they attain high throughput and low delays by controlling the number of simultaneously transmitting users.« less

  12. Is the Non-Dipole Magnetic Field Random?

    NASA Technical Reports Server (NTRS)

    Walker, Andrew D.; Backus, George E.

    1996-01-01

    Statistical modelling of the Earth's magnetic field B has a long history. In particular, the spherical harmonic coefficients of scalar fields derived from B can be treated as Gaussian random variables. In this paper, we give examples of highly organized fields whose spherical harmonic coefficients pass tests for independent Gaussian random variables. The fact that coefficients at some depth may be usefully summarized as independent samples from a normal distribution need not imply that there really is some physical, random process at that depth. In fact, the field can be extremely structured and still be regarded for some purposes as random. In this paper, we examined the radial magnetic field B(sub r) produced by the core, but the results apply to any scalar field on the core-mantle boundary (CMB) which determines B outside the CMB.

  13. Open-Access, Low-Magnetic-Field MRI System for Lung Research

    NASA Technical Reports Server (NTRS)

    Mair, Ross W.; Rosen, Matthew S.; Tsai, Leo L.; Walsworth, Ronald L.; Hrovat, Mirko I.; Patz, Samuel; Ruset, Iullian C.; Hersman, F. William

    2009-01-01

    An open-access magnetic resonance imaging (MRI) system is being developed for use in research on orientational/gravitational effects on lung physiology and function. The open-access geometry enables study of human subjects in diverse orientations. This system operates at a magnetic flux density, considerably smaller than the flux densities of typical other MRI systems, that can be generated by resistive electromagnet coils (instead of the more-expensive superconducting coils of the other systems). The human subject inhales air containing He-3 or Xe-129 atoms, the nuclear spins of which have been polarized by use of a laser beam to obtain a magnetic resonance that enables high-resolution gas space imaging at the low applied magnetic field. The system includes a bi-planar, constant-current, four-coil electromagnet assembly and associated electronic circuitry to apply a static magnetic field of 6.5 mT throughout the lung volume; planar coils and associated circuitry to apply a pulsed magnetic-field-gradient for each spatial dimension; a single, detachable radio-frequency coil and associated circuitry for inducing and detecting MRI signals; a table for supporting a horizontal subject; and electromagnetic shielding surrounding the electromagnet coils.

  14. Quantum random access memory.

    PubMed

    Giovannetti, Vittorio; Lloyd, Seth; Maccone, Lorenzo

    2008-04-25

    A random access memory (RAM) uses n bits to randomly address N=2(n) distinct memory cells. A quantum random access memory (QRAM) uses n qubits to address any quantum superposition of N memory cells. We present an architecture that exponentially reduces the requirements for a memory call: O(logN) switches need be thrown instead of the N used in conventional (classical or quantum) RAM designs. This yields a more robust QRAM algorithm, as it in general requires entanglement among exponentially less gates, and leads to an exponential decrease in the power needed for addressing. A quantum optical implementation is presented.

  15. Rippled graphene in an in-plane magnetic field: effects of a random vector potential.

    PubMed

    Lundeberg, Mark B; Folk, Joshua A

    2010-10-01

    We report measurements of the effects of a random vector potential generated by applying an in-plane magnetic field to a graphene flake. Magnetic flux through the ripples cause orbital effects: Phase-coherent weak localization is suppressed, while quasirandom Lorentz forces lead to anisotropic magnetoresistance. Distinct signatures of these two effects enable the ripple size to be characterized.

  16. Phase Diagram of a Three-Dimensional Antiferromagnet with Random Magnetic Anisotropy

    DOE PAGES

    Perez, Felio A.; Borisov, Pavel; Johnson, Trent A.; ...

    2015-03-04

    Three-dimensional (3D) antiferromagnets with random magnetic anisotropy (RMA) that were experimentally studied to date have competing two-dimensional and three-dimensional exchange interactions which can obscure the authentic effects of RMA. The magnetic phase diagram of Fe xNi 1-xF 2 epitaxial thin films with true random single-ion anisotropy was deduced from magnetometry and neutron scattering measurements and analyzed using mean field theory. Regions with uniaxial, oblique and easy plane anisotropies were identified. A RMA-induced glass region was discovered where a Griffiths-like breakdown of long-range spin order occurs.

  17. Sub-molecular modulation of a 4f driven Kondo resonance by surface-induced asymmetry

    NASA Astrophysics Data System (ADS)

    Warner, Ben; El Hallak, Fadi; Atodiresei, Nicolae; Seibt, Philipp; Prüser, Henning; Caciuc, Vasile; Waters, Michael; Fisher, Andrew J.; Blügel, Stefan; van Slageren, Joris; Hirjibehedin, Cyrus F.

    2016-09-01

    Coupling between a magnetic impurity and an external bath can give rise to many-body quantum phenomena, including Kondo and Hund's impurity states in metals, and Yu-Shiba-Rusinov states in superconductors. While advances have been made in probing the magnetic properties of d-shell impurities on surfaces, the confinement of f orbitals makes them difficult to access directly. Here we show that a 4f driven Kondo resonance can be modulated spatially by asymmetric coupling between a metallic surface and a molecule containing a 4f-like moment. Strong hybridization of dysprosium double-decker phthalocyanine with Cu(001) induces Kondo screening of the central magnetic moment. Misalignment between the symmetry axes of the molecule and the surface induces asymmetry in the molecule's electronic structure, spatially mediating electronic access to the magnetic moment through the Kondo resonance. This work demonstrates the important role that molecular ligands have in mediating electronic and magnetic coupling and in accessing many-body quantum states.

  18. 75 FR 14467 - In the Matter of: Certain Dynamic Random Access Memory Semiconductors and Products Containing...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-03-25

    ... Access Memory Semiconductors and Products Containing Same, Including Memory Modules; Notice of... the sale within the United States after importation of certain dynamic random access memory semiconductors and products containing same, including memory modules, by reason of infringement of certain...

  19. Random Interchange of Magnetic Connectivity

    NASA Astrophysics Data System (ADS)

    Matthaeus, W. H.; Ruffolo, D. J.; Servidio, S.; Wan, M.; Rappazzo, A. F.

    2015-12-01

    Magnetic connectivity, the connection between two points along a magnetic field line, has a stochastic character associated with field lines random walking in space due to magnetic fluctuations, but connectivity can also change in time due to dynamical activity [1]. For fluctuations transverse to a strong mean field, this connectivity change be caused by stochastic interchange due to component reconnection. The process may be understood approximately by formulating a diffusion-like Fokker-Planck coefficient [2] that is asymptotically related to standard field line random walk. Quantitative estimates are provided, for transverse magnetic field models and anisotropic models such as reduced magnetohydrodynamics. In heliospheric applications, these estimates may be useful for understanding mixing between open and close field line regions near coronal hole boundaries, and large latitude excursions of connectivity associated with turbulence. [1] A. F. Rappazzo, W. H. Matthaeus, D. Ruffolo, S. Servidio & M. Velli, ApJL, 758, L14 (2012) [2] D. Ruffolo & W. Matthaeus, ApJ, 806, 233 (2015)

  20. A registry-based randomized trial comparing radial and femoral approaches in women undergoing percutaneous coronary intervention: the SAFE-PCI for Women (Study of Access Site for Enhancement of PCI for Women) trial.

    PubMed

    Rao, Sunil V; Hess, Connie N; Barham, Britt; Aberle, Laura H; Anstrom, Kevin J; Patel, Tejan B; Jorgensen, Jesse P; Mazzaferri, Ernest L; Jolly, Sanjit S; Jacobs, Alice; Newby, L Kristin; Gibson, C Michael; Kong, David F; Mehran, Roxana; Waksman, Ron; Gilchrist, Ian C; McCourt, Brian J; Messenger, John C; Peterson, Eric D; Harrington, Robert A; Krucoff, Mitchell W

    2014-08-01

    This study sought to determine the effect of radial access on outcomes in women undergoing percutaneous coronary intervention (PCI) using a registry-based randomized trial. Women are at increased risk of bleeding and vascular complications after PCI. The role of radial access in women is unclear. Women undergoing cardiac catheterization or PCI were randomized to radial or femoral arterial access. Data from the CathPCI Registry and trial-specific data were merged into a final study database. The primary efficacy endpoint was Bleeding Academic Research Consortium type 2, 3, or 5 bleeding or vascular complications requiring intervention. The primary feasibility endpoint was access site crossover. The primary analysis cohort was the subgroup undergoing PCI; sensitivity analyses were conducted in the total randomized population. The trial was stopped early for a lower than expected event rate. A total of 1,787 women (691 undergoing PCI) were randomized at 60 sites. There was no significant difference in the primary efficacy endpoint between radial or femoral access among women undergoing PCI (radial 1.2% vs. 2.9% femoral, odds ratio [OR]: 0.39; 95% confidence interval [CI]: 0.12 to 1.27); among women undergoing cardiac catheterization or PCI, radial access significantly reduced bleeding and vascular complications (0.6% vs. 1.7%; OR: 0.32; 95% CI: 0.12 to 0.90). Access site crossover was significantly higher among women assigned to radial access (PCI cohort: 6.1% vs. 1.7%; OR: 3.65; 95% CI: 1.45 to 9.17); total randomized cohort: (6.7% vs. 1.9%; OR: 3.70; 95% CI: 2.14 to 6.40). More women preferred radial access. In this pragmatic trial, which was terminated early, the radial approach did not significantly reduce bleeding or vascular complications in women undergoing PCI. Access site crossover occurred more often in women assigned to radial access. (SAFE-PCI for Women; NCT01406236). Copyright © 2014 American College of Cardiology Foundation. Published by Elsevier Inc. All rights reserved.

  1. Magnetic resonance signal moment determination using the Earth's magnetic field.

    PubMed

    Fridjonsson, E O; Creber, S A; Vrouwenvelder, J S; Johns, M L

    2015-03-01

    We demonstrate a method to manipulate magnetic resonance data such that the moments of the signal spatial distribution are readily accessible. Usually, magnetic resonance imaging relies on data acquired in so-called k-space which is subsequently Fourier transformed to render an image. Here, via analysis of the complex signal in the vicinity of the centre of k-space we are able to access the first three moments of the signal spatial distribution, ultimately in multiple directions. This is demonstrated for biofouling of a reverse osmosis (RO) membrane module, rendering unique information and an early warning of the onset of fouling. The analysis is particularly applicable for the use of mobile magnetic resonance spectrometers; here we demonstrate it using an Earth's magnetic field system. Copyright © 2015 Elsevier Inc. All rights reserved.

  2. Dynamic Resource Allocation and Access Class Barring Scheme for Delay-Sensitive Devices in Machine to Machine (M2M) Communications.

    PubMed

    Li, Ning; Cao, Chao; Wang, Cong

    2017-06-15

    Supporting simultaneous access of machine-type devices is a critical challenge in machine-to-machine (M2M) communications. In this paper, we propose an optimal scheme to dynamically adjust the Access Class Barring (ACB) factor and the number of random access channel (RACH) resources for clustered machine-to-machine (M2M) communications, in which Delay-Sensitive (DS) devices coexist with Delay-Tolerant (DT) ones. In M2M communications, since delay-sensitive devices share random access resources with delay-tolerant devices, reducing the resources consumed by delay-sensitive devices means that there will be more resources available to delay-tolerant ones. Our goal is to optimize the random access scheme, which can not only satisfy the requirements of delay-sensitive devices, but also take the communication quality of delay-tolerant ones into consideration. We discuss this problem from the perspective of delay-sensitive services by adjusting the resource allocation and ACB scheme for these devices dynamically. Simulation results show that our proposed scheme realizes good performance in satisfying the delay-sensitive services as well as increasing the utilization rate of the random access resources allocated to them.

  3. High density submicron magnetoresistive random access memory (invited)

    NASA Astrophysics Data System (ADS)

    Tehrani, S.; Chen, E.; Durlam, M.; DeHerrera, M.; Slaughter, J. M.; Shi, J.; Kerszykowski, G.

    1999-04-01

    Various giant magnetoresistance material structures were patterned and studied for their potential as memory elements. The preferred memory element, based on pseudo-spin valve structures, was designed with two magnetic stacks (NiFeCo/CoFe) of different thickness with Cu as an interlayer. The difference in thickness results in dissimilar switching fields due to the shape anisotropy at deep submicron dimensions. It was found that a lower switching current can be achieved when the bits have a word line that wraps around the bit 1.5 times. Submicron memory elements integrated with complementary metal-oxide-semiconductor (CMOS) transistors maintained their characteristics and no degradation to the CMOS devices was observed. Selectivity between memory elements in high-density arrays was demonstrated.

  4. 75 FR 20564 - Dynamic Random Access Memory Semiconductors from the Republic of Korea: Extension of Time Limit...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-04-20

    ... DEPARTMENT OF COMMERCE International Trade Administration [C-580-851] Dynamic Random Access Memory Semiconductors from the Republic of Korea: Extension of Time Limit for Preliminary Results of Countervailing Duty... access memory semiconductors from the Republic of Korea, covering the period January 1, 2008 through...

  5. Statistical characteristics of trajectories of diamagnetic unicellular organisms in a magnetic field.

    PubMed

    Gorobets, Yu I; Gorobets, O Yu

    2015-01-01

    The statistical model is proposed in this paper for description of orientation of trajectories of unicellular diamagnetic organisms in a magnetic field. The statistical parameter such as the effective energy is calculated on basis of this model. The resulting effective energy is the statistical characteristics of trajectories of diamagnetic microorganisms in a magnetic field connected with their metabolism. The statistical model is applicable for the case when the energy of the thermal motion of bacteria is negligible in comparison with their energy in a magnetic field and the bacteria manifest the significant "active random movement", i.e. there is the randomizing motion of the bacteria of non thermal nature, for example, movement of bacteria by means of flagellum. The energy of the randomizing active self-motion of bacteria is characterized by the new statistical parameter for biological objects. The parameter replaces the energy of the randomizing thermal motion in calculation of the statistical distribution. Copyright © 2014 Elsevier Ltd. All rights reserved.

  6. Anisotropy Induced Switching Field Distribution in High-Density Patterned Media

    NASA Astrophysics Data System (ADS)

    Talapatra, A.; Mohanty, J.

    We present here micromagnetic study of variation of switching field distribution (SFD) in a high-density patterned media as a function of magnetic anisotropy of the system. We consider the manifold effect of magnetic anisotropy in terms of its magnitude, tilt in anisotropy axis and random arrangements of magnetic islands with random anisotropy values. Our calculation shows that reduction in anisotropy causes linear decrease in coercivity because the anisotropy energy tries to align the spins along a preferred crystallographic direction. Tilt in anisotropy axis results in decrease in squareness of the hysteresis loop and hence facilitates switching. Finally, the experimental challenges like lithographic distribution of magnetic islands, their orientation, creation of defects, etc. demanded the distribution of anisotropy to be random along with random repetitions. We have explained that the range of anisotropy values and the number of bits with different anisotropy play a key role over SFD, whereas the position of the bits and their repetitions do not show a considerable contribution.

  7. Tensor of effective susceptibility in random magnetic composites: Application to two-dimensional and three-dimensional cases

    NASA Astrophysics Data System (ADS)

    Posnansky, Oleg P.

    2018-05-01

    The measuring of dynamic magnetic susceptibility by nuclear magnetic resonance is used for revealing information about the internal structure of various magnetoactive composites. The response of such material on the applied external static and time-varying magnetic fields encodes intrinsic dynamic correlations and depends on links between macroscopic effective susceptibility and structure on the microscopic scale. In the current work we carried out computational analysis of the frequency dependent dynamic magnetic susceptibility and demonstrated its dependence on the microscopic architectural elements while also considering Euclidean dimensionality. The proposed numerical method is efficient in the simulation of nuclear magnetic resonance experiments in two- and three-dimensional random magnetic media by choosing and modeling the influence of the concentration of components and internal hierarchical characteristics of physical parameters.

  8. Temperature dependent characteristics of the random telegraph noise on contact resistive random access memory

    NASA Astrophysics Data System (ADS)

    Chang, Liang-Shun; Lin, Chrong Jung; King, Ya-Chin

    2014-01-01

    The temperature dependent characteristics of the random telegraphic noise (RTN) on contact resistive random access memory (CRRAM) are studied in this work. In addition to the bi-level switching, the occurrences of the middle states in the RTN signal are investigated. Based on the unique its temperature dependent characteristics, a new temperature sensing scheme is proposed for applications in ultra-low power sensor modules.

  9. Two non linear dynamics plasma astrophysics experiments at LANL

    NASA Astrophysics Data System (ADS)

    Intrator, T. P.; Weber, T. E.; Feng, Y.; Sears, J. A.; Swan, H.; Hutchinson, T.; Boguski, J.; Gao, K.; Chapdelaine, L.; Dunn, J.

    2013-10-01

    Two laboratory experiments at Los Alamos National Laboratory (LANL) have been built to gain access to a wide range of fundamental plasma physics issues germane astro, space, and fusion plasmas. The over arching theme is magnetized plasma dynamics that include currents, MHD forces and instabilities, sheared flows and shocks, creation and annihilation of magnetic field. The Reconnection Scaling Experiment (RSX) creates current sheets and flux ropes that exhibit fully 3D dynamics, that can kink, bounce, merge and reconnect, shred, and reform in complicated ways. The most recent movies from a large detailed data set describe the 3D magnetic structure and helicity budget of a driven and dissipative system that spontaneously self saturates a kink instability. The Magnetized Shock Experiment (MSX) uses a Field reversed configuration (FRC) that is ejected at high speed and then stagnated onto a stopping mirror field, which drives a collisionless magnetized shock. A plasmoid accelerator will also access super critical shocks at much larger Alfven Mach numbers. Unique features include access to parallel, oblique and perpendicular shocks, in regions much larger than ion gyro radius and inertial length, large magnetic and fluid Reynolds numbers, and volume for turbulence. Center for Magnetic Self Organization, NASA Geospace NNHIOA044I-Basic, Department of Energy DE-AC52-06NA25369.

  10. Critical Behavior of the Annealed Ising Model on Random Regular Graphs

    NASA Astrophysics Data System (ADS)

    Can, Van Hao

    2017-11-01

    In Giardinà et al. (ALEA Lat Am J Probab Math Stat 13(1):121-161, 2016), the authors have defined an annealed Ising model on random graphs and proved limit theorems for the magnetization of this model on some random graphs including random 2-regular graphs. Then in Can (Annealed limit theorems for the Ising model on random regular graphs, arXiv:1701.08639, 2017), we generalized their results to the class of all random regular graphs. In this paper, we study the critical behavior of this model. In particular, we determine the critical exponents and prove a non standard limit theorem stating that the magnetization scaled by n^{3/4} converges to a specific random variable, with n the number of vertices of random regular graphs.

  11. BEOL compatible high tunnel magneto resistance perpendicular magnetic tunnel junctions using a sacrificial Mg layer as CoFeB free layer cap

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Swerts, J., E-mail: Johan.Swerts@imec.be; Mertens, S.; Lin, T.

    Perpendicularly magnetized MgO-based tunnel junctions are envisaged for future generation spin-torque transfer magnetoresistive random access memory devices. Achieving a high tunnel magneto resistance and preserving it together with the perpendicular magnetic anisotropy during BEOL CMOS processing are key challenges to overcome. The industry standard technique to deposit the CoFeB/MgO/CoFeB tunnel junctions is physical vapor deposition. In this letter, we report on the use of an ultrathin Mg layer as free layer cap to protect the CoFeB free layer from sputtering induced damage during the Ta electrode deposition. When Ta is deposited directly on CoFeB, a fraction of the surface ofmore » the CoFeB is sputtered even when Ta is deposited with very low deposition rates. When depositing a thin Mg layer prior to Ta deposition, the sputtering of CoFeB is prevented. The ultra-thin Mg layer is sputtered completely after Ta deposition. Therefore, the Mg acts as a sacrificial layer that protects the CoFeB from sputter-induced damage during the Ta deposition. The Ta-capped CoFeB free layer using the sacrificial Mg interlayer has significantly better electrical and magnetic properties than the equivalent stack without protective layer. We demonstrate a tunnel magneto resistance increase up to 30% in bottom pinned magnetic tunnel junctions and tunnel magneto resistance values of 160% at resistance area product of 5 Ω.μm{sup 2}. Moreover, the free layer maintains perpendicular magnetic anisotropy after 400 °C annealing.« less

  12. Magnetic field line random walk in models and simulations of reduced magnetohydrodynamic turbulence

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Snodin, A. P.; Ruffolo, D.; Oughton, S.

    2013-12-10

    The random walk of magnetic field lines is examined numerically and analytically in the context of reduced magnetohydrodynamic (RMHD) turbulence, which provides a useful description of plasmas dominated by a strong mean field, such as in the solar corona. A recently developed non-perturbative theory of magnetic field line diffusion is compared with the diffusion coefficients obtained by accurate numerical tracing of magnetic field lines for both synthetic models and direct numerical simulations of RMHD. Statistical analysis of an ensemble of trajectories confirms the applicability of the theory, which very closely matches the numerical field line diffusion coefficient as a functionmore » of distance z along the mean magnetic field for a wide range of the Kubo number R. This theory employs Corrsin's independence hypothesis, sometimes thought to be valid only at low R. However, the results demonstrate that it works well up to R = 10, both for a synthetic RMHD model and an RMHD simulation. The numerical results from the RMHD simulation are compared with and without phase randomization, demonstrating a clear effect of coherent structures on the field line random walk for a very low Kubo number.« less

  13. Global diffusion of cosmic rays in random magnetic fields

    NASA Astrophysics Data System (ADS)

    Snodin, A. P.; Shukurov, A.; Sarson, G. R.; Bushby, P. J.; Rodrigues, L. F. S.

    2016-04-01

    The propagation of charged particles, including cosmic rays, in a partially ordered magnetic field is characterized by a diffusion tensor whose components depend on the particle's Larmor radius RL and the degree of order in the magnetic field. Most studies of the particle diffusion presuppose a scale separation between the mean and random magnetic fields (e.g. there being a pronounced minimum in the magnetic power spectrum at intermediate scales). Scale separation is often a good approximation in laboratory plasmas, but not in most astrophysical environments such as the interstellar medium (ISM). Modern simulations of the ISM have numerical resolution of the order of 1 pc, so the Larmor radius of the cosmic rays that dominate in energy density is at least 106 times smaller than the resolved scales. Large-scale simulations of cosmic ray propagation in the ISM thus rely on oversimplified forms of the diffusion tensor. We take the first steps towards a more realistic description of cosmic ray diffusion for such simulations, obtaining direct estimates of the diffusion tensor from test particle simulations in random magnetic fields (with the Larmor radius scale being fully resolved), for a range of particle energies corresponding to 10-2 ≲ RL/lc ≲ 103, where lc is the magnetic correlation length. We obtain explicit expressions for the cosmic ray diffusion tensor for RL/lc ≪ 1, that might be used in a sub-grid model of cosmic ray diffusion. The diffusion coefficients obtained are closely connected with existing transport theories that include the random walk of magnetic lines.

  14. Two Non Linear Dynamics Plasma Astrophysics Experiments At LANL

    NASA Astrophysics Data System (ADS)

    Intrator, T.; Weber, T.; Feng, Y.; Sears, J.; Smith, R. J.; Swan, H.; Hutchinson, T.; Boguski, J.; Gao, K.; Chapdelaine, L.; Dunn, J. P.

    2013-12-01

    Two laboratory experiments at Los Alamos National Laboratory (LANL) have been built to gain access to a wide range of fundamental plasma physics issues germane to astro, space, and fusion plasmas. The over arching theme is magnetized plasma dynamics that include currents, MHD forces and instabilities, sheared flows and shocks, along with creation and annihilation of magnetic field. The Relaxation Scaling Experiment (RSX) creates current sheets and flux ropes that exhibit fully 3D dynamics, that are observed to kink, bounce, merge and reconnect, shred, and reform in complicated ways. We show recent movies from a large detailed data set that describe the 3D magnetic structure and helicity budget of a driven and dissipative system that spontaneously self saturates a kink instability. The Magnetized Shock Experiment (MSX) uses a Field reversed configuration (FRC) that is ejected at high speed and then stagnated onto a stopping mirror field, which drives a collisionless magnetized shock. A plasmoid accelerator will also access super critical shocks at much larger Alfven Mach numbers. Unique features include access to parallel, oblique and perpendicular shocks, in regions much larger than ion gyro radius and inertial length, large magnetic and fluid Reynolds numbers, and volume for turbulence.

  15. 76 FR 55417 - In the Matter of Certain Dynamic Random Access Memory and Nand Flash Memory Devices and Products...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-09-07

    ... Access Memory and Nand Flash Memory Devices and Products Containing Same; Notice of Institution of... importation, and the sale within the United States after importation of certain dynamic random access memory and NAND flash memory devices and products containing same by reason of infringement of certain claims...

  16. Barrier breakdown mechanism in nano-scale perpendicular magnetic tunnel junctions with ultrathin MgO barrier

    NASA Astrophysics Data System (ADS)

    Lv, Hua; Leitao, Diana C.; Hou, Zhiwei; Freitas, Paulo P.; Cardoso, Susana; Kämpfe, Thomas; Müller, Johannes; Langer, Juergen; Wrona, Jerzy

    2018-05-01

    Recently, the perpendicular magnetic tunnel junctions (p-MTJs) arouse great interest because of its unique features in the application of spin-transfer-torque magnetoresistive random access memory (STT-MRAM), such as low switching current density, good thermal stability and high access speed. In this paper, we investigated current induced switching (CIS) in ultrathin MgO barrier p-MTJs with dimension down to 50 nm. We obtained a CIS perpendicular tunnel magnetoresistance (p-TMR) of 123.9% and 7.0 Ω.μm2 resistance area product (RA) with a critical switching density of 1.4×1010 A/m2 in a 300 nm diameter junction. We observe that the extrinsic breakdown mechanism dominates, since the resistance of our p-MTJs decreases gradually with the increasing current. From the statistical analysis of differently sized p-MTJs, we observe that the breakdown voltage (Vb) of 1.4 V is 2 times the switching voltage (Vs) of 0.7 V and the breakdown process exhibits two different breakdown states, unsteady and steady state. Using Simmons' model, we find that the steady state is related with the barrier height of the MgO layer. Furthermore, our study suggests a more efficient method to evaluate the MTJ stability under high bias rather than measuring Vb. In conclusion, we developed well performant p-MTJs for the use in STT-MRAM and demonstrate the mechanism and control of breakdown in nano-scale ultrathin MgO barrier p-MTJs.

  17. Effect of alignment of easy axes on dynamic magnetization of immobilized magnetic nanoparticles

    NASA Astrophysics Data System (ADS)

    Yoshida, Takashi; Matsugi, Yuki; Tsujimura, Naotaka; Sasayama, Teruyoshi; Enpuku, Keiji; Viereck, Thilo; Schilling, Meinhard; Ludwig, Frank

    2017-04-01

    In some biomedical applications of magnetic nanoparticles (MNPs), the particles are physically immobilized. In this study, we explore the effect of the alignment of the magnetic easy axes on the dynamic magnetization of immobilized MNPs under an AC excitation field. We prepared three immobilized MNP samples: (1) a sample in which easy axes are randomly oriented, (2) a parallel-aligned sample in which easy axes are parallel to the AC field, and (3) an orthogonally aligned sample in which easy axes are perpendicular to the AC field. First, we show that the parallel-aligned sample has the largest hysteresis in the magnetization curve and the largest harmonic magnetization spectra, followed by the randomly oriented and orthogonally aligned samples. For example, 1.6-fold increase was observed in the area of the hysteresis loop of the parallel-aligned sample compared to that of the randomly oriented sample. To quantitatively discuss the experimental results, we perform a numerical simulation based on a Fokker-Planck equation, in which probability distributions for the directions of the easy axes are taken into account in simulating the prepared MNP samples. We obtained quantitative agreement between experiment and simulation. These results indicate that the dynamic magnetization of immobilized MNPs is significantly affected by the alignment of the easy axes.

  18. Static magnetic therapy does not decrease pain or opioid requirements: a randomized double-blind trial.

    PubMed

    Cepeda, M Soledad; Carr, Daniel B; Sarquis, Tony; Miranda, Nelcy; Garcia, Ricardo J; Zarate, Camilo

    2007-02-01

    A growing multibillion dollar industry markets magnetic necklaces, bracelets, bands, insoles, back braces, mattresses, etc., for pain relief, although there is little evidence for their efficacy. We sought to evaluate the effect of magnetic therapy on pain intensity and opioid requirements in patients with postoperative pain. We designed a randomized, double-blind, controlled trial. One-hundred-sixty-five patients older than 12 yr of age were randomized to magnetic (n = 81) or sham therapy (n = 84) upon reporting moderate-to-severe pain in the postanesthesia care unit. Devices were placed over the surgical incision and left in place for 2 h. Patients rated their pain intensity on a 0-10 scale every 10 min and received incremental doses of morphine until pain intensity was < or =4 of 10. Pain intensity levels were similar in both groups. The magnet group had on average 0.04 U more pain intensity (95% confidence interval, -0.4 to 0.5) than the sham group. Opioid requirements also were similar in both groups. The active magnet group required 1.5 mg more morphine (95% confidence interval, -1.8 to 4.0) than the sham magnet group. Magnetic therapy lacks efficacy in controlling acute postoperative pain intensity levels or opioid requirements and should not be recommended for pain relief in this setting.

  19. Nature of magnetization and lateral spin-orbit interaction in gated semiconductor nanowires.

    PubMed

    Karlsson, H; Yakimenko, I I; Berggren, K-F

    2018-05-31

    Semiconductor nanowires are interesting candidates for realization of spintronics devices. In this paper we study electronic states and effects of lateral spin-orbit coupling (LSOC) in a one-dimensional asymmetrically biased nanowire using the Hartree-Fock method with Dirac interaction. We have shown that spin polarization can be triggered by LSOC at finite source-drain bias,as a result of numerical noise representing a random magnetic field due to wiring or a random background magnetic field by Earth magnetic field, for instance. The electrons spontaneously arrange into spin rows in the wire due to electron interactions leading to a finite spin polarization. The direction of polarization is, however, random at zero source-drain bias. We have found that LSOC has an effect on orientation of spin rows only in the case when source-drain bias is applied.

  20. Nature of magnetization and lateral spin–orbit interaction in gated semiconductor nanowires

    NASA Astrophysics Data System (ADS)

    Karlsson, H.; Yakimenko, I. I.; Berggren, K.-F.

    2018-05-01

    Semiconductor nanowires are interesting candidates for realization of spintronics devices. In this paper we study electronic states and effects of lateral spin–orbit coupling (LSOC) in a one-dimensional asymmetrically biased nanowire using the Hartree–Fock method with Dirac interaction. We have shown that spin polarization can be triggered by LSOC at finite source-drain bias,as a result of numerical noise representing a random magnetic field due to wiring or a random background magnetic field by Earth magnetic field, for instance. The electrons spontaneously arrange into spin rows in the wire due to electron interactions leading to a finite spin polarization. The direction of polarization is, however, random at zero source-drain bias. We have found that LSOC has an effect on orientation of spin rows only in the case when source-drain bias is applied.

  1. Reversible susceptibility studies of magnetization switching in FeCoB synthetic antiferromagnets

    NASA Astrophysics Data System (ADS)

    Radu, Cosmin; Cimpoesu, Dorin; Girt, Erol; Ju, Ganping; Stancu, Alexandru; Spinu, Leonard

    2007-05-01

    In this paper we present a study of switching characteristics of a series of synthetic antiferromagnet (SAF) structures using reversible susceptibility experiments. Three series of SAF samples were considered in our study with (t1, t2), the thickness of the FeCoB layers of (80nm, 80nm), (50nm, 50nm), and (80nm, 20nm) and with the interlayer of Ru ranging from 0to2nm. A vector vibrating sample magnetometer was used to measure the hysteresis loops along the different directions in the plane of the samples. The reversible susceptibility experiments were performed using a resonant method based on a tunnel diode oscillator. We showed that the switching peaks in the susceptibility versus field plots obtained for different orientations of the applied dc field can be used to construct the switching diagram of the SAF structure. The critical curve constitutes the fingerprint of the switching behavior and provides information about micromagnetic and structural properties of SAF which is an essential component of modern magnetic random access memories.

  2. [Influence of low frequency magnetic field used in magnetotherapy on interleukin 6 (IL-6) contents in rat heart and brain].

    PubMed

    Ciejka, Elżbieta; Skibska, Beata; Gorąca, Anna

    2017-06-27

    The human population is exposed ever more frequently to magnetic fields (MF). This is due to both technological progress and development of the economy as well as to advances made in medical science. That is why the thorough understanding and systematized knowledge about mechanisms by which MF exerts its effects on living organisms play such an important role. In this context the health of MF-exposed people is the subject of particular concern. The aim of the study was to evaluate the effect of extremely low frequency magnetic field (ELFMF) used in magnetotherapy on the concentration of interleukin 6 (IL-6) in rat heart and brain. The male rats were randomly divided into 3 experimental groups: group I - control, without contact with magnetic field; group II - exposed to bipolar, rectangular magnetic field 40 Hz, induction "peak-to-peak" 7 mT 30 min/day for 2 weeks; and group III - exposed to bipolar, rectangular magnetic field 40 Hz, 7 mT 60 min/day for 2 weeks. Concentration of IL-6 in the heart and brain of animals was measured after MF exposure. Exposure to ELFMF: 40 Hz, induction "peak-to-peak" 7 mT 30 min/day for 2 weeks caused a significant IL-6 increase in rat hearts compared to the control group (p < 0.05) and a non-significant IL-6 decrease in rat brain. The magnetic field applied for 60 min resulted in non-significant IL-6 increase in rat hearts compared to the control group and significant IL-6 decrease in rat brain (p < 0.05). The influence of magnetic field on inflammation in the body varies depending on the MF parameters and the affected tissues or cells. Med Pr 2017;68(4):517-523. This work is available in Open Access model and licensed under a CC BY-NC 3.0 PL license.

  3. Magnetic localization and orientation of the capsule endoscope based on a random complex algorithm.

    PubMed

    He, Xiaoqi; Zheng, Zizhao; Hu, Chao

    2015-01-01

    The development of the capsule endoscope has made possible the examination of the whole gastrointestinal tract without much pain. However, there are still some important problems to be solved, among which, one important problem is the localization of the capsule. Currently, magnetic positioning technology is a suitable method for capsule localization, and this depends on a reliable system and algorithm. In this paper, based on the magnetic dipole model as well as magnetic sensor array, we propose nonlinear optimization algorithms using a random complex algorithm, applied to the optimization calculation for the nonlinear function of the dipole, to determine the three-dimensional position parameters and two-dimensional direction parameters. The stability and the antinoise ability of the algorithm is compared with the Levenberg-Marquart algorithm. The simulation and experiment results show that in terms of the error level of the initial guess of magnet location, the random complex algorithm is more accurate, more stable, and has a higher "denoise" capacity, with a larger range for initial guess values.

  4. Analysis of Document Authentication Technique using Soft Magnetic Fibers

    NASA Astrophysics Data System (ADS)

    Aoki, Ayumi; Ikeda, Takashi; Yamada, Tsutomu; Takemura, Yasushi; Matsumoto, Tsutomu

    An artifact-metric system using magnetic fibers can be applied for authentications of stock certificate, bill, passport, plastic cards and other documents. Security of the system is guaranteed by its feature of difficulty in copy. This authentication system is based on randomly dispersed magnetic fibers embedded in documents. In this paper, a theoretical analysis was performed in order to evaluate this system. The position of the magnetic fibers was determined by a conventional function of random number generator. By measuring output waveforms by a magnetoresistance (MR) sensor, a false match rate (FMR) could be calculated. Optimizations of the density of the magnetic fibers and the dimension of the MR sensor were achieved.

  5. BCH codes for large IC random-access memory systems

    NASA Technical Reports Server (NTRS)

    Lin, S.; Costello, D. J., Jr.

    1983-01-01

    In this report some shortened BCH codes for possible applications to large IC random-access memory systems are presented. These codes are given by their parity-check matrices. Encoding and decoding of these codes are discussed.

  6. 76 FR 35238 - Notice of Receipt of Complaint; Solicitation of Comments Relating to the Public Interest

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-06-16

    ... Static Random Access Memories and Products Containing Same, DN 2816; the Commission is soliciting... importation of certain static random access memories and products containing same. The complaint names as...

  7. Random-access technique for modular bathymetry data storage in a continental shelf wave refraction program

    NASA Technical Reports Server (NTRS)

    Poole, L. R.

    1974-01-01

    A study was conducted of an alternate method for storage and use of bathymetry data in the Langley Research Center and Virginia Institute of Marine Science mid-Atlantic continental-shelf wave-refraction computer program. The regional bathymetry array was divided into 105 indexed modules which can be read individually into memory in a nonsequential manner from a peripheral file using special random-access subroutines. In running a sample refraction case, a 75-percent decrease in program field length was achieved by using the random-access storage method in comparison with the conventional method of total regional array storage. This field-length decrease was accompanied by a comparative 5-percent increase in central processing time and a 477-percent increase in the number of operating-system calls. A comparative Langley Research Center computer system cost savings of 68 percent was achieved by using the random-access storage method.

  8. LTE-advanced random access mechanism for M2M communication: A review

    NASA Astrophysics Data System (ADS)

    Mustafa, Rashid; Sarowa, Sandeep; Jaglan, Reena Rathee; Khan, Mohammad Junaid; Agrawal, Sunil

    2016-03-01

    Machine Type Communications (MTC) enables one or more self-sufficient machines to communicate directly with one another without human interference. MTC applications include smart grid, security, e-Health and intelligent automation system. To support huge numbers of MTC devices, one of the challenging issues is to provide a competent way for numerous access in the network and to minimize network overload. In this article, the different control mechanisms for overload random access are reviewed to avoid congestion caused by random access channel (RACH) of MTC devices. However, past and present wireless technologies have been engineered for Human-to-Human (H2H) communications, in particular, for transmission of voice. Consequently the Long Term Evolution (LTE) -Advanced is expected to play a central role in communicating Machine to Machine (M2M) and are very optimistic about H2H communications. Distinct and unique characteristics of M2M communications create new challenges from those in H2H communications. In this article, we investigate the impact of massive M2M terminals attempting random access to LTE-Advanced all at once. We discuss and review the solutions to alleviate the overload problem by Third Generation Partnership Project (3GPP). As a result, we evaluate and compare these solutions that can effectively eliminate the congestion on the random access channel for M2M communications without affecting H2H communications.

  9. Evidence of Magnetic Inversion in Single Ni Nanoparticles

    DOE PAGES

    Jiang, W.; Gartland, P.; Davidović, D.

    2016-11-08

    Superparamagnetism is an unwanted property of small magnetic particles where the magnetization of the particle flips randomly in time, due to thermal noise. There has been an increased attention in the properties of superparamagnetic particles recently, because of their potential applications in high density storage and medicine. In electron transport through single nanometer scale magnetic particles, the current can also cause the magnetization to flip randomly in time, even at low temperature. Here we show experimental evidence that when the current is then reduced towards zero in the applied magnetic field, the magnetization can reliably freeze about a higher anisotropy-energymore » minimum, where it tends to be inverted with respect to the magnetic field direction. Specifically, we use spin-unpolarized tunneling spectroscopy of discrete levels in single Ni particles 2–4 nm in diameter at mK-temperature, and find that the the magnetic excitation energy at the onset of current decreases when the magnetic field increases, reaching near degeneracy at nonzero magnetic field. We discuss the potential for spintronic applications such as current induced magnetization switching without any spin-polarized leads.« less

  10. Evidence of Magnetic Inversion in Single Ni Nanoparticles

    PubMed Central

    Jiang, W.; Gartland, P.; Davidović, D.

    2016-01-01

    Superparamagnetism is an unwanted property of small magnetic particles where the magnetization of the particle flips randomly in time, due to thermal noise. There has been an increased attention in the properties of superparamagnetic particles recently, because of their potential applications in high density storage and medicine. In electron transport through single nanometer scale magnetic particles, the current can also cause the magnetization to flip randomly in time, even at low temperature. Here we show experimental evidence that when the current is then reduced towards zero in the applied magnetic field, the magnetization can reliably freeze about a higher anisotropy-energy minimum, where it tends to be inverted with respect to the magnetic field direction. Specifically, we use spin-unpolarized tunneling spectroscopy of discrete levels in single Ni particles 2–4 nm in diameter at mK-temperature, and find that the the magnetic excitation energy at the onset of current decreases when the magnetic field increases, reaching near degeneracy at nonzero magnetic field. We discuss the potential for spintronic applications such as current induced magnetization switching without any spin-polarized leads. PMID:27824076

  11. New constraints on modelling the random magnetic field of the MW

    NASA Astrophysics Data System (ADS)

    Beck, Marcus C.; Beck, Alexander M.; Beck, Rainer; Dolag, Klaus; Strong, Andrew W.; Nielaba, Peter

    2016-05-01

    We extend the description of the isotropic and anisotropic random component of the small-scale magnetic field within the existing magnetic field model of the Milky Way from Jansson & Farrar, by including random realizations of the small-scale component. Using a magnetic-field power spectrum with Gaussian random fields, the NE2001 model for the thermal electrons and the Galactic cosmic-ray electron distribution from the current GALPROP model we derive full-sky maps for the total and polarized synchrotron intensity as well as the Faraday rotation-measure distribution. While previous work assumed that small-scale fluctuations average out along the line-of-sight or which only computed ensemble averages of random fields, we show that these fluctuations need to be carefully taken into account. Comparing with observational data we obtain not only good agreement with 408 MHz total and WMAP7 22 GHz polarized intensity emission maps, but also an improved agreement with Galactic foreground rotation-measure maps and power spectra, whose amplitude and shape strongly depend on the parameters of the random field. We demonstrate that a correlation length of 0≈22 pc (05 pc being a 5σ lower limit) is needed to match the slope of the observed power spectrum of Galactic foreground rotation-measure maps. Using multiple realizations allows us also to infer errors on individual observables. We find that previously-used amplitudes for random and anisotropic random magnetic field components need to be rescaled by factors of ≈0.3 and 0.6 to account for the new small-scale contributions. Our model predicts a rotation measure of -2.8±7.1 rad/m2 and 04.4±11. rad/m2 for the north and south Galactic poles respectively, in good agreement with observations. Applying our model to deflections of ultra-high-energy cosmic rays we infer a mean deflection of ≈3.5±1.1 degree for 60 EeV protons arriving from CenA.

  12. Method for Evaluation of Outage Probability on Random Access Channel in Mobile Communication Systems

    NASA Astrophysics Data System (ADS)

    Kollár, Martin

    2012-05-01

    In order to access the cell in all mobile communication technologies a so called random-access procedure is used. For example in GSM this is represented by sending the CHANNEL REQUEST message from Mobile Station (MS) to Base Transceiver Station (BTS) which is consequently forwarded as an CHANNEL REQUIRED message to the Base Station Controller (BSC). If the BTS decodes some noise on the Random Access Channel (RACH) as random access by mistake (so- called ‘phantom RACH') then it is a question of pure coincidence which èstablishment cause’ the BTS thinks to have recognized. A typical invalid channel access request or phantom RACH is characterized by an IMMEDIATE ASSIGNMENT procedure (assignment of an SDCCH or TCH) which is not followed by sending an ESTABLISH INDICATION from MS to BTS. In this paper a mathematical model for evaluation of the Power RACH Busy Threshold (RACHBT) in order to guaranty in advance determined outage probability on RACH is described and discussed as well. It focuses on Global System for Mobile Communications (GSM) however the obtained results can be generalized on remaining mobile technologies (ie WCDMA and LTE).

  13. Electrical-current-induced magnetic hysteresis in self-assembled vertically aligned L a 2 / 3 S r 1 / 3 Mn O 3 : ZnO nanopillar composites

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Pan, W.; Lu, P.; Ihlefeld, J. F.

    Magnetoresistive random-access memory (MRAM) is poised to become a next-generation information storage device. Yet, many materials challenges remain unsolved before it can become a widely used memory storage solution. Among them, an urgent need is to identify a material system that is suitable for downscaling and is compatible with low-power logic applications. Self-assembled, vertically aligned La 2/3Sr 1/3MnO 3: ZnO nanocomposites, in which La 2/3Sr 1/3MnO 3 (LSMO) matrix and ZnO nanopillars form an intertwined structure with coincident-site-matched growth occurring between the LSMO and ZnO vertical interfaces, may offer new MRAM applications by combining their superior electric, magnetic ( Bmore » ), and optical properties. Here, in this Rapid Communication, we show the results of electrical current induced magnetic hysteresis in magnetoresistance measurements in these nanopillar composites. We observe that when the current level is low, for example, 1 µA, the magnetoresistance displays a linear, negative, nonhysteretic B field dependence. Surprisingly, when a large current is used, I > 10 µA, a hysteretic behavior is observed when the B field is swept in the up and down directions. This hysteresis weakens as the sample temperature is increased. Finally, a possible spin-valve mechanism related to this electrical current induced magnetic hysteresis is proposed and discussed.« less

  14. Perpendicular magnetic anisotropy in CoXPd100-X alloys for magnetic tunnel junctions

    NASA Astrophysics Data System (ADS)

    Clark, B. D.; Natarajarathinam, A.; Tadisina, Z. R.; Chen, P. J.; Shull, R. D.; Gupta, S.

    2017-08-01

    CoFeB/MgO-based perpendicular magnetic tunnel junctions (p-MTJ's) with high anisotropy and low damping are critical for spin-torque transfer random access memory (STT-RAM). Most schemes of making the pinned CoFeB fully perpendicular require ferrimagnets with high damping constants, a high temperature-grown L10 alloy, or an overly complex multilayered synthetic antiferromagnet (SyAF). We report a compositional study of perpendicular CoxPd alloy-pinned Co20Fe60B20/MgO based MTJ stacks, grown at moderate temperatures in a planetary deposition system. The perpendicular anisotropy of the CoxPd alloy films can be tuned based on the layer thickness and composition. The films were characterized by alternating gradient magnetometry (AGM), energy-dispersive X-rays (EDX), and X-ray diffraction (XRD). Current-in-plane tunneling (CIPT) measurements have also been performed on the compositionally varied CoxPd MTJ stacks. The CoxPd alloy becomes fully perpendicular at approximately x = 30% (atomic fraction) Co. Full-film MTJ stacks of Si/SiO2/MgO (13)/CoXPd100-x (50)/Ta (0.3)/CoFeB (1)/MgO (1.6)/CoFeB (1)/Ta (5)/Ru (10), with the numbers enclosed in parentheses being the layer thicknesses in nm, were sputtered onto thermally oxidized silicon substrates and in-situ lamp annealed at 400 °C for 5 min. CIPT measurements indicate that the highest TMR is observed for the CoPd composition with the highest perpendicular magnetic anisotropy.

  15. Electrical-current-induced magnetic hysteresis in self-assembled vertically aligned L a 2 / 3 S r 1 / 3 Mn O 3 : ZnO nanopillar composites

    DOE PAGES

    Pan, W.; Lu, P.; Ihlefeld, J. F.; ...

    2018-02-22

    Magnetoresistive random-access memory (MRAM) is poised to become a next-generation information storage device. Yet, many materials challenges remain unsolved before it can become a widely used memory storage solution. Among them, an urgent need is to identify a material system that is suitable for downscaling and is compatible with low-power logic applications. Self-assembled, vertically aligned La 2/3Sr 1/3MnO 3: ZnO nanocomposites, in which La 2/3Sr 1/3MnO 3 (LSMO) matrix and ZnO nanopillars form an intertwined structure with coincident-site-matched growth occurring between the LSMO and ZnO vertical interfaces, may offer new MRAM applications by combining their superior electric, magnetic ( Bmore » ), and optical properties. Here, in this Rapid Communication, we show the results of electrical current induced magnetic hysteresis in magnetoresistance measurements in these nanopillar composites. We observe that when the current level is low, for example, 1 µA, the magnetoresistance displays a linear, negative, nonhysteretic B field dependence. Surprisingly, when a large current is used, I > 10 µA, a hysteretic behavior is observed when the B field is swept in the up and down directions. This hysteresis weakens as the sample temperature is increased. Finally, a possible spin-valve mechanism related to this electrical current induced magnetic hysteresis is proposed and discussed.« less

  16. A non-axial superconducting magnet design for optimized patient access and minimal SAD for use in a Linac-MR hybrid: proof of concept.

    PubMed

    Yaghoobpour Tari, Shima; Wachowicz, Keith; Gino Fallone, B

    2017-04-21

    A prototype rotating hybrid magnetic resonance imaging system and linac has been developed to allow for simultaneous imaging and radiation delivery parallel to B 0 . However, the design of a compact magnet capable of rotation in a small vault with sufficient patient access and a typical clinical source-to-axis distance (SAD) is challenging. This work presents a novel superconducting magnet design as a proof of concept that allows for a reduced SAD and ample patient access by moving the superconducting coils to the side of the yoke. The yoke and pole-plate structures are shaped to direct the magnetic flux appropriately. The outer surface of the pole plate is optimized subject to the minimization of a cost function, which evaluates the uniformity of the magnetic field over an ellipsoid. The magnetic field calculations required in this work are performed with the 3D finite element method software package Opera-3D. Each tentative design strategy is virtually modeled in this software package, which is externally controlled by MATLAB, with its key geometries defined as variables. The optimization variables are the thickness of the pole plate at control points distributed over the pole plate surface. A novel design concept as a superconducting non-axial magnet is introduced, which could create a large uniform B 0 magnetic field with fewer geometric restriction. This non-axial 0.5 T superconducting magnet has a moderately reduced SAD of 123 cm and a vertical patient opening of 68 cm. This work is presented as a proof of principle to investigate the feasibility of a non-axial magnet with the coils located around the yoke, and the results encourage future design optimizations to maximize the benefits of this non-axial design.

  17. A non-axial superconducting magnet design for optimized patient access and minimal SAD for use in a Linac-MR hybrid: proof of concept

    NASA Astrophysics Data System (ADS)

    Yaghoobpour Tari, Shima; Wachowicz, Keith; Fallone, B. Gino

    2017-04-01

    A prototype rotating hybrid magnetic resonance imaging system and linac has been developed to allow for simultaneous imaging and radiation delivery parallel to B 0. However, the design of a compact magnet capable of rotation in a small vault with sufficient patient access and a typical clinical source-to-axis distance (SAD) is challenging. This work presents a novel superconducting magnet design as a proof of concept that allows for a reduced SAD and ample patient access by moving the superconducting coils to the side of the yoke. The yoke and pole-plate structures are shaped to direct the magnetic flux appropriately. The outer surface of the pole plate is optimized subject to the minimization of a cost function, which evaluates the uniformity of the magnetic field over an ellipsoid. The magnetic field calculations required in this work are performed with the 3D finite element method software package Opera-3D. Each tentative design strategy is virtually modeled in this software package, which is externally controlled by MATLAB, with its key geometries defined as variables. The optimization variables are the thickness of the pole plate at control points distributed over the pole plate surface. A novel design concept as a superconducting non-axial magnet is introduced, which could create a large uniform B 0 magnetic field with fewer geometric restriction. This non-axial 0.5 T superconducting magnet has a moderately reduced SAD of 123 cm and a vertical patient opening of 68 cm. This work is presented as a proof of principle to investigate the feasibility of a non-axial magnet with the coils located around the yoke, and the results encourage future design optimizations to maximize the benefits of this non-axial design.

  18. The random energy model in a magnetic field and joint source channel coding

    NASA Astrophysics Data System (ADS)

    Merhav, Neri

    2008-09-01

    We demonstrate that there is an intimate relationship between the magnetic properties of Derrida’s random energy model (REM) of spin glasses and the problem of joint source-channel coding in Information Theory. In particular, typical patterns of erroneously decoded messages in the coding problem have “magnetization” properties that are analogous to those of the REM in certain phases, where the non-uniformity of the distribution of the source in the coding problem plays the role of an external magnetic field applied to the REM. We also relate the ensemble performance (random coding exponents) of joint source-channel codes to the free energy of the REM in its different phases.

  19. Micromechanics-based magneto-elastic constitutive modeling of particulate composites

    NASA Astrophysics Data System (ADS)

    Yin, Huiming

    Modified Green's functions are derived for three situations: a magnetic field caused by a local magnetization, a displacement field caused by a local body force and a displacement field caused by a local prescribed eigenstrain. Based on these functions, an explicit solution is derived for two magnetic particles embedded in the infinite medium under external magnetic and mechanical loading. A general solution for numerable magnetic particles embedded in an infinite domain is then provided in integral form. Two-phase composites containing spherical magnetic particles of the same size are considered for three kinds of microstructures. With chain-structured composites, particle interactions in the same chain are considered and a transversely isotropic effective elasticity is obtained. For periodic composites, an eight-particle interaction model is developed and provides a cubic symmetric effective elasticity. In the random composite, pair-wise particle interactions are integrated from all possible positions and an isotropic effective property is reached. This method is further extended to functionally graded composites. Magneto-mechanical behavior is studied for the chain-structured composite and the random composite. Effective magnetic permeability, effective magnetostriction and field-dependent effective elasticity are investigated. It is seen that the chain-structured composite is more sensitive to the magnetic field than the random composite; a composite consisting of only 5% of chain-structured particles can provide a larger magnetostriction and a larger change of effective elasticity than an equivalent composite consisting of 30% of random dispersed particles. Moreover, the effective shear modulus of the chain-structured composite rapidly increases with the magnetic field, while that for the random composite decreases. An effective hyperelastic constitutive model is further developed for a magnetostrictive particle-filled elastomer, which is sampled by using a network of body-centered cubic lattices of particles connected by macromolecular chains. The proposed hyperelastic model is able to characterize overall nonlinear elastic stress-stretch relations of the composites under general three-dimensional loading. It is seen that the effective strain energy density is proportional to the length of stretched chains in unit volume and volume fraction of particles.

  20. The Challenges Facing Science Data Archiving on Current Mass Storage Systems

    NASA Technical Reports Server (NTRS)

    Peavey, Bernard; Behnke, Jeanne (Editor)

    1996-01-01

    This paper discusses the desired characteristics of a tape-based petabyte science data archive and retrieval system required to store and distribute several terabytes (TB) of data per day over an extended period of time, probably more than 115 years, in support of programs such as the Earth Observing System Data and Information System (EOSDIS). These characteristics take into consideration not only cost effective and affordable storage capacity, but also rapid access to selected files, and reading rates that are needed to satisfy thousands of retrieval transactions per day. It seems that where rapid random access to files is not crucial, the tape medium, magnetic or optical, continues to offer cost effective data storage and retrieval solutions, and is likely to do so for many years to come. However, in environments like EOS these tape based archive solutions provide less than full user satisfaction. Therefore, the objective of this paper is to describe the performance and operational enhancements that need to be made to the current tape based archival systems in order to achieve greater acceptance by the EOS and similar user communities.

  1. Optoelectronic-cache memory system architecture.

    PubMed

    Chiarulli, D M; Levitan, S P

    1996-05-10

    We present an investigation of the architecture of an optoelectronic cache that can integrate terabit optical memories with the electronic caches associated with high-performance uniprocessors and multiprocessors. The use of optoelectronic-cache memories enables these terabit technologies to provide transparently low-latency secondary memory with frame sizes comparable with disk pages but with latencies that approach those of electronic secondary-cache memories. This enables the implementation of terabit memories with effective access times comparable with the cycle times of current microprocessors. The cache design is based on the use of a smart-pixel array and combines parallel free-space optical input-output to-and-from optical memory with conventional electronic communication to the processor caches. This cache and the optical memory system to which it will interface provide a large random-access memory space that has a lower overall latency than that of magnetic disks and disk arrays. In addition, as a consequence of the high-bandwidth parallel input-output capabilities of optical memories, fault service times for the optoelectronic cache are substantially less than those currently achievable with any rotational media.

  2. Sono-electro-magnetic therapy for treating chronic pelvic pain syndrome in men: a randomized, placebo-controlled, double-blind trial.

    PubMed

    Kessler, Thomas M; Mordasini, Livio; Weisstanner, Christian; Jüni, Peter; da Costa, Bruno R; Wiest, Roland; Thalmann, George N

    2014-01-01

    To assess the efficacy and safety of sono-electro-magnetic therapy compared to placebo in men with refractory CPPS. In a randomized, placebo-controlled, double-blind single center trial, we assessed the effect of sono-electro-magnetic therapy in men with treatment refractory CPPS. Sixty male patients were randomly assigned to treatment with either sono-electro-magnetic (n = 30) or placebo therapy (n = 30) for 12 weeks. The primary outcome was a change in the National Institutes of Health Chronic Prostatitis Symptom Index (NIH-CPSI) from baseline to 12 weeks. The 12-week difference between sono-electro-magnetic and placebo therapy in changes of the NIH-CPSI total score was -3.1 points (95% CI -6.8 to 0.6, p = 0.11). In secondary comparisons of NIH-CPSI sub-scores, we found differences between groups most pronounced for the quality-of-life sub-score (difference at 12 weeks -1.6, 95% CI -2.8 to -0.4, p = 0.015). In stratified analyses, the benefit of sono-electro-magnetic therapy appeared more pronounced among patients who had a symptom duration of 12 months or less (difference in NIH-CPSI total score -8.3, 95% CI -14.5 to 2.6) than in patients with a longer symptom duration (-0.8, 95% CI -4.6 to 3.1; p for interaction = 0.023). Sono-electro-magnetic therapy did not result in a significant improvement of symptoms in the overall cohort of treatment refractory CPPS patients compared to placebo treatment. Subgroup analysis indicates, however, that patients with a symptom-duration of 12 months or less may benefit from sono-electro-magnetic therapy, warranting larger randomized controlled trials in this subpopulation. ClinicalTrials.gov NCT00688506.

  3. Stochastic Resonance and Safe Basin of Single-Walled Carbon Nanotubes with Strongly Nonlinear Stiffness under Random Magnetic Field.

    PubMed

    Xu, Jia; Li, Chao; Li, Yiran; Lim, Chee Wah; Zhu, Zhiwen

    2018-05-04

    In this paper, a kind of single-walled carbon nanotube nonlinear model is developed and the strongly nonlinear dynamic characteristics of such carbon nanotubes subjected to random magnetic field are studied. The nonlocal effect of the microstructure is considered based on Eringen’s differential constitutive model. The natural frequency of the strongly nonlinear dynamic system is obtained by the energy function method, the drift coefficient and the diffusion coefficient are verified. The stationary probability density function of the system dynamic response is given and the fractal boundary of the safe basin is provided. Theoretical analysis and numerical simulation show that stochastic resonance occurs when varying the random magnetic field intensity. The boundary of safe basin has fractal characteristics and the area of safe basin decreases when the intensity of the magnetic field permeability increases.

  4. Magnetic noise as the cause of the spontaneous magnetization reversal of RE–TM–B permanent magnets

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Dmitriev, A. I., E-mail: aid@icp.ac.ru; Talantsev, A. D., E-mail: artgtx32@mail.ru; Kunitsyna, E. I.

    2016-08-15

    The relation between the macroscopic spontaneous magnetization reversal (magnetic viscosity) of (NdDySm)(FeCo)B alloys and the spectral characteristics of magnetic noise, which is caused by the random microscopic processes of thermally activated domain wall motion in a potential landscape with uniformly distributed potential barrier heights, is found.

  5. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Gottwald, M.; Kan, J. J.; Lee, K.

    Thermal budget, stack thickness, and dipolar offset field control are crucial for seamless integration of perpendicular magnetic junctions (pMTJ) into semiconductor integrated circuits to build scalable spin-transfer-torque magnetoresistive random access memory. This paper is concerned with materials and process tuning to deliver thermally robust (400 °C, 30 min) and thin (i.e., fewer layers and integration-friendly) pMTJ utilizing Co/Pt-based bottom pinned layers. Interlayer roughness control is identified as a key enabler to achieve high thermal budgets. The dipolar offset fields of the developed film stacks at scaled dimensions are evaluated by micromagnetic simulations. This paper shows a path towards achieving sub-15 nm-thick pMTJ withmore » tunneling magnetoresistance ratio higher than 150% after 30 min of thermal excursion at 400 °C.« less

  6. Optimization of Materials and Interfaces for Spintronic Devices

    NASA Astrophysics Data System (ADS)

    Clark, Billy

    In recent years' Spintronic devices have drawn a significant amount of research attention. This interest comes in large part from their ability to enable interesting and new technology such as Spin Torque Transfer Random Access Memory or improve existing technology such as High Signal Read Heads for Hard Disk Drives. For the former we worked on optimizing and improving magnetic tunnel junctions by optimizing their thermal stability by using Ta insertion layers in the free layer. We further tried to simplify the design of the MTJ stack by attempting to replace the Co/Pd multilayer with CoPd alloy. In this dissertation, we detail its development and examine the switching characteristics. Lastly we look at a highly spin polarized material, Fe2MnGe, for optimizing Hard Drive Disk read heads.

  7. Random walk study of electron motion in helium in crossed electromagnetic fields

    NASA Technical Reports Server (NTRS)

    Englert, G. W.

    1972-01-01

    Random walk theory, previously adapted to electron motion in the presence of an electric field, is extended to include a transverse magnetic field. In principle, the random walk approach avoids mathematical complexity and concomitant simplifying assumptions and permits determination of energy distributions and transport coefficients within the accuracy of available collisional cross section data. Application is made to a weakly ionized helium gas. Time of relaxation of electron energy distribution, determined by the random walk, is described by simple expressions based on energy exchange between the electron and an effective electric field. The restrictive effect of the magnetic field on electron motion, which increases the required number of collisions per walk to reach a terminal steady state condition, as well as the effect of the magnetic field on electron transport coefficients and mean energy can be quite adequately described by expressions involving only the Hall parameter.

  8. The random field Blume-Capel model revisited

    NASA Astrophysics Data System (ADS)

    Santos, P. V.; da Costa, F. A.; de Araújo, J. M.

    2018-04-01

    We have revisited the mean-field treatment for the Blume-Capel model under the presence of a discrete random magnetic field as introduced by Kaufman and Kanner (1990). The magnetic field (H) versus temperature (T) phase diagrams for given values of the crystal field D were recovered in accordance to Kaufman and Kanner original work. However, our main goal in the present work was to investigate the distinct structures of the crystal field versus temperature phase diagrams as the random magnetic field is varied because similar models have presented reentrant phenomenon due to randomness. Following previous works we have classified the distinct phase diagrams according to five different topologies. The topological structure of the phase diagrams is maintained for both H - T and D - T cases. Although the phase diagrams exhibit a richness of multicritical phenomena we did not found any reentrant effect as have been seen in similar models.

  9. Static magnetism and thermal switching in randomly oriented L10 FePt thin films

    NASA Astrophysics Data System (ADS)

    Lisfi, A.; Pokharel, S.; Alqarni, A.; Akioya, O.; Morgan, W.; Wuttig, M.

    2018-05-01

    Static magnetism and thermally activated magnetic relaxation were investigated in granular FePt films (20 nm-200 nm thick) with random magnetic anisotropy through hysteresis loop, torque curve and magnetization time dependence measurements. While the magnetism of thicker film (200 nm thick) is dominated by a single switching of the ordered L10 phase, thinner film (20 nm) displays a double switching, which is indicative of the presence of the disordered cubic phase. The pronounced behavior of double switching in thinner film suggests that the film grain boundary is composed of soft cubic magnetic phase. The magnetic relaxation study reveals that magnetic viscosity S of the films is strongly dependent on the external applied field and exhibits a maximum value (12 kAm) around the switching field and a vanishing behavior at low (1 kOe) and large (12 kOe) fields. The activation volume of the thermal switching was found to be much smaller than the physical volume of the granular structure due to the incoherent rotation mode of the magnetization reversal mechanism, which is established to be domain wall nucleation.

  10. EDITORIAL: Spin-transfer-torque-induced phenomena Spin-transfer-torque-induced phenomena

    NASA Astrophysics Data System (ADS)

    Hirohata, Atsufumi

    2011-09-01

    This cluster, consisting of five invited articles on spin-transfer torque, offers the very first review covering both magnetization reversal and domain-wall displacement induced by a spin-polarized current. Since the first theoretical proposal on spin-transfer torque—reported by Berger and Slonczewski independently—spin-transfer torque has been experimentally demonstrated in both vertical magnetoresistive nano-pillars and lateral ferromagnetic nano-wires. In the former structures, an electrical current flowing vertically in the nano-pillar exerts spin torque onto the thinner ferromagnetic layer and reverses its magnetization, i.e., current-induced magnetization switching. In the latter structures, an electrical current flowing laterally in the nano-wire exerts torque onto a domain wall and moves its position by rotating local magnetic moments within the wall, i.e., domain wall displacement. Even though both phenomena are induced by spin-transfer torque, each phenomenon has been investigated separately. In order to understand the physical meaning of spin torque in a broader context, this cluster overviews both cases from theoretical modellings to experimental demonstrations. The earlier articles in this cluster focus on current-induced magnetization switching. The magnetization dynamics during the reversal has been calculated by Kim et al using the conventional Landau--Lifshitz-Gilbert (LLG) equation, adding a spin-torque term. This model can explain the dynamics in both spin-valves and magnetic tunnel junctions in a nano-pillar form. This phenomenon has been experimentally measured in these junctions consisting of conventional ferromagnets. In the following experimental part, the nano-pillar junctions with perpendicularly magnetized FePt and half-metallic Heusler alloys are discussed from the viewpoint of efficient magnetization reversal due to a high degree of spin polarization of the current induced by the intrinsic nature of these alloys. Such switching can be further operated at high frequency resulting in an oscillator, as shown in the article by Sulka et al. These results provide fundamental elements for magnetic random access memories. The later articles discuss domain-wall displacement. Again this phenomenon is also described by Shibata et al based on the LLG equation with spin-torque terms. This analytical model can explain the details of the depinning mechanism and a critical current for the displacement. Experimental observation is presented in the subsequent article by Malinowski et al, showing the depinning processes for the cases of intrinsic and extrinsic pinning sites. Here, the detailed magnetic moment configurations within the wall hold the dominant control over the critical current. These results can be used for future 3-dimensional magnetic memories, such as racetrack memory proposed by IBM. We sincerely hope this cluster offers an up-to-date understanding of macroscopic behaviour induced by spin-transfer torque and contributes to further advancement in this exciting research field. We are grateful to all the authors for spending their precious time and knowledge submitting to this cluster. We would also like to thank Professor Kevin O'Grady for his kind offer of the opportunity to make this review accessible to a general audience.

  11. Zero field reversal probability in thermally assisted magnetization reversal

    NASA Astrophysics Data System (ADS)

    Prasetya, E. B.; Utari; Purnama, B.

    2017-11-01

    This paper discussed about zero field reversal probability in thermally assisted magnetization reversal (TAMR). Appearance of reversal probability in zero field investigated through micromagnetic simulation by solving stochastic Landau-Lifshitz-Gibert (LLG). The perpendicularly anisotropy magnetic dot of 50×50×20 nm3 is considered as single cell magnetic storage of magnetic random acces memory (MRAM). Thermally assisted magnetization reversal was performed by cooling writing process from near/almost Curie point to room temperature on 20 times runs for different randomly magnetized state. The results show that the probability reversal under zero magnetic field decreased with the increase of the energy barrier. The zero-field probability switching of 55% attained for energy barrier of 60 k B T and the reversal probability become zero noted at energy barrier of 2348 k B T. The higest zero-field switching probability of 55% attained for energy barrier of 60 k B T which corespond to magnetif field of 150 Oe for switching.

  12. Randomized comparison of the magnetic navigation system vs. standard wires in the treatment of bifurcations.

    PubMed

    Ramcharitar, Steve; van der Giessen, Willem J; van der Ent, Martin; Serruys, Patrick W; van Geuns, Robert Jan

    2011-06-01

    Aims Randomly compare the magnetic navigation system (MNS) to standard guidewire techniques in managing bifurcating lesions. Methods and results Thirty-one consecutive patients with bifurcating lesions were randomized to cross the bifurcating vessels prior to treatment and thereafter the struts of deployed stents with either magnetic or standard guidewires. Crossing success, crossing/fluoroscopy times, and contrast media usage were directly compared. Similar times were noted in both the magnetic wire crossings (median, IQR; 68 s, 45-138 s vs. 59 s, 32-133 s) and fluoroscopic times (median, IQR; 62 s, 44-135 s vs. 55 s, 27-133 s) when compared with standard conventional wires passage through the deployed struts. The MNS successful crossings were 30/31 (96.8%) compared with 28/31 (90.0%) observed with the standard wires. Two previously failed standard wire cases were successfully crossed with magnetic guidewires. Conclusion In contemporary stented bifurcations, the MNS achieved equivalent crossing/fluoroscopy times through deployed stents struts and may be useful in salvaging failed standard wire cases.

  13. A transportable magnetic resonance imaging system for in situ measurements of living trees: the Tree Hugger.

    PubMed

    Jones, M; Aptaker, P S; Cox, J; Gardiner, B A; McDonald, P J

    2012-05-01

    This paper presents the design of the 'Tree Hugger', an open access, transportable, 1.1 MHz (1)H nuclear magnetic resonance imaging system for the in situ analysis of living trees in the forest. A unique construction employing NdFeB blocks embedded in a reinforced carbon fibre frame is used to achieve access up to 210 mm and to allow the magnet to be transported. The magnet weighs 55 kg. The feasibility of imaging living trees in situ using the 'Tree Hugger' is demonstrated. Correlations are drawn between NMR/MRI measurements and other indicators such as relative humidity, soil moisture and net solar radiation. Copyright © 2012 Elsevier Inc. All rights reserved.

  14. Remote Magnetic Navigation for Catheter Ablation in Patients With Congenital Heart Disease: A Review.

    PubMed

    Roy, Karine; Gomez-Pulido, Federico; Ernst, Sabine

    2016-03-01

    In patients with congenital heart disease, challenges to catheter-based arrhythmia interventions are unique and numerous given the complexity of the underlying defects, anatomic and surgical intervention variants including baffles, conduits, patches, and/or shunts. Remote magnetic navigation offers significant advantages in these cases that may present with limited vascular access or difficult access to the target cardiac chambers implicated by the previous surgical interventions. We reviewed the data available on the safety, feasibility, and effectiveness of magnetic navigation for the treatment of arrhythmia in congenital heart disease and discussed the specific challenges related to various congenital defects and repair with the potential advantages offered by magnetic navigation in these circumstances. © 2016 Wiley Periodicals, Inc.

  15. Development of Curie point switching for thin film, random access, memory device

    NASA Technical Reports Server (NTRS)

    Lewicki, G. W.; Tchernev, D. I.

    1967-01-01

    Managanese bismuthide films are used in the development of a random access memory device of high packing density and nondestructive readout capability. Memory entry is by Curie point switching using a laser beam. Readout is accomplished by microoptical or micromagnetic scanning.

  16. A comparison of Percutaneous femoral access in Endovascular Repair versus Open femoral access (PiERO): study protocol for a randomized controlled trial.

    PubMed

    Vierhout, Bastiaan P; Saleem, Ben R; Ott, Alewijn; van Dijl, Jan Maarten; de Kempenaer, Ties D van Andringa; Pierie, Maurice E N; Bottema, Jan T; Zeebregts, Clark J

    2015-09-14

    Access for endovascular repair of abdominal aortic aneurysms (EVAR) is obtained through surgical cutdown or percutaneously. The only devices suitable for percutaneous closure of the 20 French arteriotomies of the common femoral artery (CFA) are the Prostar(™) and Proglide(™) devices (Abbott Vascular). Positive effects of these devices seem to consist of a lower infection rate, and shorter operation time and hospital stay. This conclusion was published in previous reports comparing techniques in patients in two different groups (cohort or randomized). Access techniques were never compared in one and the same patient; this research simplifies comparison because patient characteristics will be similar in both groups. Percutaneous access of the CFA is compared to surgical cutdown in a single patient; in EVAR surgery, access is necessary in both groins in each patient. Randomization is performed on the introduction site of the larger main device of the endoprosthesis. The contralateral device of the endoprosthesis is smaller. When we use this type of randomization, both groups will contain a similar number of main and contralateral devices. Preoperative nose cultures and perineal cultures are obtained, to compare colonization with postoperative wound cultures (in case of a surgical site infection). Furthermore, patient comfort will be considered, using VAS-scores (Visual analog scale). Punch biopsies of the groin will be harvested to retrospectively compare skin of patients who suffered a surgical site infection (SSI) to patients who did not have an SSI. The PiERO trial is a multicenter randomized controlled clinical trial designed to show the consequences of using percutaneous access in EVAR surgery and focuses on the occurrence of surgical site infections. NTR4257 10 November 2013, NL44578.042.13.

  17. Restricted access magnetic materials prepared by dual surface modification for selective extraction of therapeutic drugs from biological fluids

    NASA Astrophysics Data System (ADS)

    Wang, Yu; Wang, Yuxia; Chen, Lei; Wan, Qian-Hong

    2012-02-01

    Magnetic porous particles with dual functionality have been prepared by a two-step procedure and evaluated as novel restricted access materials for extraction of therapeutic agents from biological fluids. The magnetic silica particles served as scaffolds were first modified with diol groups, which were then converted to octadecyl esters through reaction with stearoyl chloride. In the second step, the octadecyl esters on the exterior surface were hydrolyzed by the action of lipase to yield magnetic particles with hydrophobic reversed-phase ligands on the inner surface and biocompatible diol groups on the outer surface. The restricted access behavior of the resulting materials was confirmed by differential binding of small molecules such as methotrexate (MTX), leucovorin (LV) and folic acid (FA) relative to bovine serum albumin. While MTX, LV and FA were all bound to the magnetic particles with high affinity, the adsorption of the protein was markedly reduced due to size exclusion effect. The utility of the magnetic particles for sample preparation was tested in solid-phase extraction of MTX, LV and FA from spiked human serum and the effects of the SPE conditions on the recovery of the analytes were systematically studied. Moreover, the magnetic particle-based sample preparation procedure coupled with reversed-phase liquid chromatography analysis was validated in terms of specificity, linearity and reproducibility. The method was shown to be free from interference of endogenous compounds and linear over the concentration range of 0.5-10 μg/mL for the three drugs studied. The limits of detection for the three drugs in serum were in the range of 0.160-0.302 μg/mL. Reproducibility expressed as the RSD of the recovery for ten replicated extractions at three different concentrations was found to be less than 8.93%. With a unique combination of surface functionality with magnetic cores, the restricted access magnetic particles may be adapted in automated and high throughput protocols for routine analysis of a large volume of clinical samples.

  18. A randomized, controlled trial of magnetic therapy for carpal tunnel syndrome.

    PubMed

    Baute, Vanessa; Keskinyan, Vahakn S; Sweeney, Erica R; Bowden, Kayla D; Gordon, Allison; Hutchens, Janet; Cartwright, Michael S

    2018-03-07

    Magnet therapy has been proposed as a treatment for neurologic conditions. In this this trial we assessed the feasibility and efficacy of a magnet inserted into a wristband for carpal tunnel syndrome (CTS). Twenty-two patients with mild to moderate CTS were randomized to wear a high-dose or low-dose "sham" magnetic wristband for 6 weeks. The primary outcome was the Symptom Severity Scale (SSS) of the Boston Carpal Tunnel Questionnaire. Secondary measures were nerve conduction studies (NCS), median nerve ultrasound, and compliance. Compliance for both groups was >90%. Improvements in the mean SSS, NCS, and median nerve ultrasound did not reach statistical significance. Magnet therapy via wristband is well-tolerated. Further investigations in larger populations are needed to determine efficacy. Muscle Nerve, 2018. © 2018 Wiley Periodicals, Inc.

  19. Realisation of all 16 Boolean logic functions in a single magnetoresistance memory cell

    NASA Astrophysics Data System (ADS)

    Gao, Shuang; Yang, Guang; Cui, Bin; Wang, Shouguo; Zeng, Fei; Song, Cheng; Pan, Feng

    2016-06-01

    Stateful logic circuits based on next-generation nonvolatile memories, such as magnetoresistance random access memory (MRAM), promise to break the long-standing von Neumann bottleneck in state-of-the-art data processing devices. For the successful commercialisation of stateful logic circuits, a critical step is realizing the best use of a single memory cell to perform logic functions. In this work, we propose a method for implementing all 16 Boolean logic functions in a single MRAM cell, namely a magnetoresistance (MR) unit. Based on our experimental results, we conclude that this method is applicable to any MR unit with a double-hump-like hysteresis loop, especially pseudo-spin-valve magnetic tunnel junctions with a high MR ratio. Moreover, after simply reversing the correspondence between voltage signals and output logic values, this method could also be applicable to any MR unit with a double-pit-like hysteresis loop. These results may provide a helpful solution for the final commercialisation of MRAM-based stateful logic circuits in the near future.Stateful logic circuits based on next-generation nonvolatile memories, such as magnetoresistance random access memory (MRAM), promise to break the long-standing von Neumann bottleneck in state-of-the-art data processing devices. For the successful commercialisation of stateful logic circuits, a critical step is realizing the best use of a single memory cell to perform logic functions. In this work, we propose a method for implementing all 16 Boolean logic functions in a single MRAM cell, namely a magnetoresistance (MR) unit. Based on our experimental results, we conclude that this method is applicable to any MR unit with a double-hump-like hysteresis loop, especially pseudo-spin-valve magnetic tunnel junctions with a high MR ratio. Moreover, after simply reversing the correspondence between voltage signals and output logic values, this method could also be applicable to any MR unit with a double-pit-like hysteresis loop. These results may provide a helpful solution for the final commercialisation of MRAM-based stateful logic circuits in the near future. Electronic supplementary information (ESI) available. See DOI: 10.1039/c6nr03169b

  20. Electric and magnetic microfields inside and outside space-limited configurations of ions and ionic currents

    NASA Astrophysics Data System (ADS)

    Romanovsky, M. Yu; Ebeling, W.; Schimansky-Geier, L.

    2005-01-01

    The problem of electric and magnetic microfields inside finite spherical systems of stochastically moving ions and outside them is studied. The first possible field of applications is high temperature ion clusters created by laser fields [1]. Other possible applications are nearly spherical liquid systems at room-temperature containing electrolytes. Looking for biological applications we may also think about a cell which is a complicated electrolytic system or even a brain which is a still more complicated system of electrolytic currents. The essential model assumption is the random character of charges motion. We assume in our basic model that we have a finite nearly spherical system of randomly moving charges. Even taking into account that this is at best a caricature of any real system, it might be of interest as a limiting case, which admits a full theoretical treatment. For symmetry reasons, a random configuration of moving charges cannot generate a macroscopic magnetic field, but there will be microscopic fluctuating magnetic fields. Distributions for electric and magnetic microfields inside and outside such space- limited systems are calculated. Spherical systems of randomly distributed moving charges are investigated. Starting from earlier results for infinitely large systems, which lead to Holtsmark- type distributions, we show that the fluctuations in finite charge distributions are larger (in comparison to infinite systems of the same charge density).

  1. High density plasma etching of magnetic devices

    NASA Astrophysics Data System (ADS)

    Jung, Kee Bum

    Magnetic materials such as NiFe (permalloy) or NiFeCo are widely used in the data storage industry. Techniques for submicron patterning are required to develop next generation magnetic devices. The relative chemical inertness of most magnetic materials means they are hard to etch using conventional RIE (Reactive Ion Etching). Therefore ion milling has generally been used across the industry, but this has limitations for magnetic structures with submicron dimensions. In this dissertation, we suggest high density plasmas such as ECR (Electron Cyclotron Resonance) and ICP (Inductively Coupled Plasma) for the etching of magnetic materials (NiFe, NiFeCo, CoFeB, CoSm, CoZr) and other related materials (TaN, CrSi, FeMn), which are employed for magnetic devices like magnetoresistive random access memories (MRAM), magnetic read/write heads, magnetic sensors and microactuators. This research examined the fundamental etch mechanisms occurring in high density plasma processing of magnetic materials by measuring etch rate, surface morphology and surface stoichiometry. However, one concern with using Cl2-based plasma chemistry is the effect of residual chlorine or chlorinated etch residues remaining on the sidewalls of etched features, leading to a degradation of the magnetic properties. To avoid this problem, we employed two different processing methods. The first one is applying several different cleaning procedures, including de-ionized water rinsing or in-situ exposure to H2, O2 or SF6 plasmas. Very stable magnetic properties were achieved over a period of ˜6 months except O2 plasma treated structures, with no evidence of corrosion, provided chlorinated etch residues were removed by post-etch cleaning. The second method is using non-corrosive gas chemistries such as CO/NH3 or CO2/NH3. There is a small chemical contribution to the etch mechanism (i.e. formation of metal carbonyls) as determined by a comparison with Ar and N2 physical sputtering. The discharge should be NH3-rich to achieve the highest etch rates. Several different mask materials were investigated, including photoresist, thermal oxide and deposited oxide. Photoresist etches very rapidly in CO/NH 3 and use of a hard mask is necessary to achieve pattern transfer. Due to its physically dominated nature, the CO/NH3 chemistry appears suited to shallow etch depth (≤0.5mum) applications, but mask erosion leads to sloped feature sidewalls for deeper features.

  2. Development of Laser-Polarized Noble Gas Magnetic Resonance Imaging (MRI) Technology

    NASA Technical Reports Server (NTRS)

    Walsworth, Ronald L.

    2004-01-01

    We are developing technology for laser-polarized noble gas nuclear magnetic resonance (NMR), with the aim of enabling it as a novel biomedical imaging tool for ground-based and eventually space-based application. This emerging multidisciplinary technology enables high-resolution gas-space magnetic resonance imaging (MRI)-e.g., of lung ventilation, perfusion, and gas-exchange. In addition, laser-polarized noble gases (3He and 1BXe) do not require a large magnetic field for sensitive NMR detection, opening the door to practical MRI with novel, open-access magnet designs at very low magnetic fields (and hence in confined spaces). We are pursuing two specific aims in this technology development program. The first aim is to develop an open-access, low-field (less than 0.01 T) instrument for MRI studies of human gas inhalation as a function of subject orientation, and the second aim is to develop functional imaging of the lung using laser-polarized He-3 and Xe-129.

  3. Randomized comparison of operator radiation exposure comparing transradial and transfemoral approach for percutaneous coronary procedures: rationale and design of the minimizing adverse haemorrhagic events by TRansradial access site and systemic implementation of angioX - RAdiation Dose study (RAD-MATRIX).

    PubMed

    Sciahbasi, Alessandro; Calabrò, Paolo; Sarandrea, Alessandro; Rigattieri, Stefano; Tomassini, Francesco; Sardella, Gennaro; Zavalloni, Dennis; Cortese, Bernardo; Limbruno, Ugo; Tebaldi, Matteo; Gagnor, Andrea; Rubartelli, Paolo; Zingarelli, Antonio; Valgimigli, Marco

    2014-06-01

    Radiation absorbed by interventional cardiologists is a frequently under-evaluated important issue. Aim is to compare radiation dose absorbed by interventional cardiologists during percutaneous coronary procedures for acute coronary syndromes comparing transradial and transfemoral access. The randomized multicentre MATRIX (Minimizing Adverse Haemorrhagic Events by TRansradial Access Site and Systemic Implementation of angioX) trial has been designed to compare the clinical outcome of patients with acute coronary syndromes treated invasively according to the access site (transfemoral vs. transradial) and to the anticoagulant therapy (bivalirudin vs. heparin). Selected experienced interventional cardiologists involved in this study have been equipped with dedicated thermoluminescent dosimeters to evaluate the radiation dose absorbed during transfemoral or right transradial or left transradial access. For each access we evaluate the radiation dose absorbed at wrist, at thorax and at eye level. Consequently the operator is equipped with three sets (transfemoral, right transradial or left transradial access) of three different dosimeters (wrist, thorax and eye dosimeter). Primary end-point of the study is the procedural radiation dose absorbed by operators at thorax. An important secondary end-point is the procedural radiation dose absorbed by operators comparing the right or left radial approach. Patient randomization is performed according to the MATRIX protocol for the femoral or radial approach. A further randomization for the radial approach is performed to compare right and left transradial access. The RAD-MATRIX study will probably consent to clarify the radiation issue for interventional cardiologist comparing transradial and transfemoral access in the setting of acute coronary syndromes. Copyright © 2014 Elsevier Inc. All rights reserved.

  4. Spontaneous magnetization of quantum XY spin model in joint presence of quenched and annealed disorder

    NASA Astrophysics Data System (ADS)

    Bera, Anindita; Rakshit, Debraj; SenDe, Aditi; Sen, Ujjwal

    2017-06-01

    We investigate equilibrium statistical properties of the isotropic quantum XY spin-1/2 model in an external magnetic field when the interaction and field parts are subjected to quenched or annealed disorder or both. The randomness present in the system are termed annealed or quenched depending on the relation between two different time scales—the time scale associated with the equilibration of the randomness and the time of observation. Within a mean-field framework, we study the effects of disorders on spontaneous magnetization, both by perturbative and numerical techniques. Our primary interest is to understand the differences between quenched and annealed cases, and also to investigate the interplay when both of them are present in a system. We find that the magnetization survives in the presence of a unidirectional random field, irrespective of its nature, i.e., whether it is quenched or annealed. However, the field breaks the circular symmetry of the magnetization, and the system magnetizes in specific directions, parallel or transverse to the applied magnetic field. Interestingly, while the transverse magnetization is affected by the annealed disordered field, the parallel one remains unfazed by the same. Moreover, the annealed disorder present in the interaction term does not affect the system's spontaneous magnetization and the corresponding critical temperature, irrespective of the presence or absence of quenched or annealed disorder in the field term. We carry out a comparative study of these and all other different combinations of the disorders in the interaction and field terms, and point out their generic features.

  5. Resonant spin tunneling in randomly oriented nanospheres of Mn 12 acetate

    DOE PAGES

    Lendínez, S.; Zarzuela, R.; Tejada, J.; ...

    2015-01-06

    We report measurements and theoretical analysis of resonant spin tunneling in randomly oriented nanospheres of a molecular magnet. Amorphous nanospheres of Mn₁₂ acetate have been fabricated and characterized by chemical, infrared, TEM, X-ray, and magnetic methods. Magnetic measurements have revealed sharp tunneling peaks in the field derivative of the magnetization that occur at the typical resonant field values for the Mn₁₂ acetate crystal in the field parallel to the easy axis.Theoretical analysis is provided that explains these observations. We argue that resonant spin tunneling in a molecular magnet can be established in a powder sample, without the need for amore » single crystal and without aligning the easy magnetization axes of the molecules. This is confirmed by re-analyzing the old data on a powdered sample of non-oriented micron-size crystals of Mn₁₂ acetate. In conclusion, our findings can greatly simplify the selection of candidates for quantum spin tunneling among newly synthesized molecular magnets.« less

  6. Resonant spin tunneling in randomly oriented nanospheres of Mn 12 acetate

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Lendínez, S.; Zarzuela, R.; Tejada, J.

    We report measurements and theoretical analysis of resonant spin tunneling in randomly oriented nanospheres of a molecular magnet. Amorphous nanospheres of Mn₁₂ acetate have been fabricated and characterized by chemical, infrared, TEM, X-ray, and magnetic methods. Magnetic measurements have revealed sharp tunneling peaks in the field derivative of the magnetization that occur at the typical resonant field values for the Mn₁₂ acetate crystal in the field parallel to the easy axis.Theoretical analysis is provided that explains these observations. We argue that resonant spin tunneling in a molecular magnet can be established in a powder sample, without the need for amore » single crystal and without aligning the easy magnetization axes of the molecules. This is confirmed by re-analyzing the old data on a powdered sample of non-oriented micron-size crystals of Mn₁₂ acetate. In conclusion, our findings can greatly simplify the selection of candidates for quantum spin tunneling among newly synthesized molecular magnets.« less

  7. Characteristics of level-spacing statistics in chaotic graphene billiards.

    PubMed

    Huang, Liang; Lai, Ying-Cheng; Grebogi, Celso

    2011-03-01

    A fundamental result in nonrelativistic quantum nonlinear dynamics is that the spectral statistics of quantum systems that possess no geometric symmetry, but whose classical dynamics are chaotic, are described by those of the Gaussian orthogonal ensemble (GOE) or the Gaussian unitary ensemble (GUE), in the presence or absence of time-reversal symmetry, respectively. For massless spin-half particles such as neutrinos in relativistic quantum mechanics in a chaotic billiard, the seminal work of Berry and Mondragon established the GUE nature of the level-spacing statistics, due to the combination of the chirality of Dirac particles and the confinement, which breaks the time-reversal symmetry. A question is whether the GOE or the GUE statistics can be observed in experimentally accessible, relativistic quantum systems. We demonstrate, using graphene confinements in which the quasiparticle motions are governed by the Dirac equation in the low-energy regime, that the level-spacing statistics are persistently those of GOE random matrices. We present extensive numerical evidence obtained from the tight-binding approach and a physical explanation for the GOE statistics. We also find that the presence of a weak magnetic field switches the statistics to those of GUE. For a strong magnetic field, Landau levels become influential, causing the level-spacing distribution to deviate markedly from the random-matrix predictions. Issues addressed also include the effects of a number of realistic factors on level-spacing statistics such as next nearest-neighbor interactions, different lattice orientations, enhanced hopping energy for atoms on the boundary, and staggered potential due to graphene-substrate interactions.

  8. Preoperative Magnetic Resonance Imaging in Patients With Stage I Invasive Ductal Breast Cancer: A Prospective Randomized Study.

    PubMed

    Brück, N; Koskivuo, I; Boström, P; Saunavaara, J; Aaltonen, R; Parkkola, R

    2018-03-01

    Preoperative magnetic resonance imaging has become an important complementary imaging technique in patients with breast cancer, providing additional information for preoperative local staging. Magnetic resonance imaging is recommended selectively in lobular breast cancer and in patients with dense breast tissue in the case when mammography and ultrasound fail to fully evaluate the lesion, but the routine use of magnetic resonance imaging in all patients with invasive ductal carcinoma is controversial. The purpose of this randomized study was to investigate the diagnostic value of preoperative magnetic resonance imaging and its impact on short-term surgical outcome in newly diagnosed unifocal stage I invasive ductal carcinoma. A total of 100 patients were randomized to either receive preoperative breast magnetic resonance imaging or to be scheduled directly to operation without magnetic resonance imaging on a 1:1 basis. There were 50 patients in both study arms. In 14 patients (28%), breast magnetic resonance imaging detected an additional finding and seven of them were found to be malignant. Six additional cancer foci were found in the ipsilateral breast and one in the contralateral breast. Magnetic resonance imaging findings caused a change in planned surgical management in 10 patients (20%). Mastectomy was performed in six patients (12%) in the magnetic resonance imaging group and in two patients (4%) in the control group ( p = 0.140). The breast reoperation rate was 14% in the magnetic resonance imaging group and 24% in the control group ( p = 0.202). The mean interval between referral and first surgical procedure was 34 days in the magnetic resonance imaging group and 21 days in the control group ( p < 0.001). Preoperative magnetic resonance imaging may be beneficial for some patients with early-stage invasive ductal carcinoma, but its routine use is not recommended without specific indications.

  9. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Deschenes, Austin; Muneer, Sadid; Akbulut, Mustafa

    Thermal assistance has been shown to significantly reduce the required operation power for spin torque transfer magnetic random access memory (STT-MRAM). Proposed heating methods include modified material stack compositions that result in increased self-heating or external heat sources. Here, we analyze the self-heating process of a standard perpendicular magnetic anisotropy STT-MRAM device through numerical simulations in order to understand the relative contributions of Joule, thermoelectric Peltier and Thomson, and tunneling junction heating. A 2D rotationally symmetric numerical model is used to solve the coupled electro-thermal equations including thermoelectric effects and heat absorbed or released at the tunneling junction. We comparemore » self-heating for different common passivation materials, positive and negative electrical current polarity, and different device thermal anchoring and boundaries resistance configurations. The variations considered are found to result in significant differences in maximum temperatures reached. Average increases of 3 K, 10 K, and 100 K for different passivation materials, positive and negative polarity, and different thermal anchoring configurations, respectively, are observed. Furthermore, the highest temperatures, up to 424 K, are obtained for silicon dioxide as the passivation material, positive polarity, and low thermal anchoring with thermal boundary resistance configurations. Interestingly it is also found that due to the tunneling heat, Peltier effect, device geometry, and numerous interfacial layers around the magnetic tunnel junction (MTJ), most of the heat is dissipated on the lower potential side of the magnetic junction. We have observed this asymmetry in heating and is important as thermally assisted switching requires heating of the free layer specifically and this will be significantly different for the two polarity operations, set and reset.« less

  10. High performance perpendicular magnetic tunnel junction with Co/Ir interfacial anisotropy for embedded and standalone STT-MRAM applications

    NASA Astrophysics Data System (ADS)

    Huai, Yiming; Gan, Huadong; Wang, Zihui; Xu, Pengfa; Hao, Xiaojie; Yen, Bing K.; Malmhall, Roger; Pakala, Nirav; Wang, Cory; Zhang, Jing; Zhou, Yuchen; Jung, Dongha; Satoh, Kimihiro; Wang, Rongjun; Xue, Lin; Pakala, Mahendra

    2018-02-01

    High volume spin transfer torque magnetoresistance random access memory (STT-MRAM) for standalone and embedded applications requires a thin perpendicular magnetic tunnel junction (pMTJ) stack (˜10 nm) with a tunnel magnetoresistance (TMR) ratio over 200% after high temperature back-end-of-line (BEOL) processing up to 400 °C. A thin reference layer with low magnetic moment and strong perpendicular magnetic anisotropy (PMA) is key to reduce the total thickness of the full pMTJ stack. We demonstrated strong interfacial PMA and a perpendicular Ruderman-Kittel-Kasuya-Yosida exchange interaction in the Co/Ir system. Owing to the additional high PMA at the Ir/Co interface in combination with a conventional CoFeB/MgO interface in the Ir/Co/Mo/CoFeB/MgO reference layer, the full film pMTJ showed a TMR ratio over 210% after annealing at 400 °C for 150 min. The high TMR ratio can be attributed to the thin stack design by combining a thin reference layer with the efficient compensation by a thin pinned layer. The annealing stability may be explained by the absence of solid solution in the Co-Ir system and the low oxygen affinity of Mo in the reference layer and the free layer. High device performance with a TMR ratio over 210% was also confirmed after subjecting the patterned devices to BEOL processing temperatures of up to 400 °C. This proposed pMTJ design is suitable for both standalone and embedded STT-MRAM applications.

  11. Accessibility condition of wave propagation and multicharged ion production in electron cyclotron resonance ion source plasma.

    PubMed

    Kato, Yushi; Yano, Keisuke; Nishiokada, Takuya; Nagaya, Tomoki; Kimura, Daiju; Kumakura, Sho; Imai, Youta; Hagino, Shogo; Otsuka, Takuro; Sato, Fuminobu

    2016-02-01

    A new tandem type source of electron cyclotron resonance (ECR) plasmas has been constructing for producing synthesized ion beams in Osaka University. Magnetic mirror field configuration with octupole magnets can be controlled to various shape of ECR zones, namely, in the 2nd stage plasma to be available by a pair mirror and a supplemental coil. Noteworthy correlations between these magnetic configurations and production of multicharged ions are investigated in detail, as well as their optimum conditions. We have been considering accessibility condition of electromagnetic and electrostatic waves propagating in ECR ion source plasma, and then investigated their correspondence relationships with production of multicharged ions. It has been clarified that there exits efficient configuration of ECR zones for producing multicharged ion beams experimentally, and then has been suggested from detail accessibility conditions on the ECR plasma that new resonance, i.e., upper hybrid resonance, must have occurred.

  12. Making working memory work: The effects of extended practice on focus capacity and the processes of updating, forward access, and random access

    PubMed Central

    Price, John M.; Colflesh, Gregory J. H.; Cerella, John; Verhaeghen, Paul

    2014-01-01

    We investigated the effects of 10 hours of practice on variations of the N-Back task to investigate the processes underlying possible expansion of the focus of attention within working memory. Using subtractive logic, we showed that random access (i.e., Sternberg-like search) yielded a modest effect (a 50% increase in speed) whereas the processes of forward access (i.e., retrieval in order, as in a standard N-Back task) and updating (i.e., changing the contents of working memory) were executed about 5 times faster after extended practice. We additionally found that extended practice increased working memory capacity as measured by the size of the focus of attention for the forward-access task, but not for variations where probing was in random order. This suggests that working memory capacity may depend on the type of search process engaged, and that certain working-memory-related cognitive processes are more amenable to practice than others. PMID:24486803

  13. TU-H-BRA-04: A Novel Superconducting Magnet Design for Optimized Patient Access and Minimal SSD for Use in a Linac-MR Hybrid

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Yaghoobpour Tari, S; Wachowicz, K; Fallone, B

    2016-06-15

    Purpose: A prototype rotating hybrid MR imaging system and linac has been developed to allow for simultaneous imaging and radiation delivery parallel to B{sub 0}. However, the design of a compact magnet capable of rotation in a small vault with sufficient patient access and a typical clinical source-to-surface distance (SSD) is challenging. This work presents a novel superconducting magnet design that allows for a reduced SSD and ample patient access by moving the superconducting coils to the side of the yoke. The yoke and pole-plate structures are shaped to direct the magnetic flux appropriately. Methods: The surface of the polemore » plate for the magnet assembly is optimized. The magnetic field calculations required in this work are performed with the 3D finite element method software package Opera-3D. Each tentative design strategy is virtually modeled in this software package and externally controlled by MATLAB, with its key geometries defined as variables. The particle swarm optimization algorithm is used to optimize the variables subject to the minimization of a cost function. At each iteration, Opera-3D will solve the magnetic field solution over a field-of-view suitable for MR imaging and the degree of field uniformity will be assessed to calculate the value of the cost function associated with that iteration. Results: An optimized magnet assembly that generates a homogenous 0.2T magnetic field over an ellipsoid with large axis of 30 cm and small axes of 20 cm is obtained. Conclusion: The distinct features of this model are the minimal distance between the yoke’s top and the isocentre and the improved patient access. On the other hand, having homogeneity over an ellipsoid give us a larger field-of-view, essential for geometric accuracy of the MRI system. The increase of B{sub 0} from 0.2T in the present model to 0.5T is the subject of future work. Funding Sources: Alberta Innovates - Health Solutions (AIHS)| Disclosure and Conflict of Interest: B. Gino Fallone is a co-founder and CEO of MagnetTx Oncology Solutions (under discussions to license Alberta biplanar linac MR for commercialization).« less

  14. Electrical Evaluation of RCA MWS5501D Random Access Memory, Volume 2, Appendix a

    NASA Technical Reports Server (NTRS)

    Klute, A.

    1979-01-01

    The electrical characterization and qualification test results are presented for the RCA MWS5001D random access memory. The tests included functional tests, AC and DC parametric tests, AC parametric worst-case pattern selection test, determination of worst-case transition for setup and hold times, and a series of schmoo plots. The address access time, address readout time, the data hold time, and the data setup time are some of the results surveyed.

  15. Computer access security code system

    NASA Technical Reports Server (NTRS)

    Collins, Earl R., Jr. (Inventor)

    1990-01-01

    A security code system for controlling access to computer and computer-controlled entry situations comprises a plurality of subsets of alpha-numeric characters disposed in random order in matrices of at least two dimensions forming theoretical rectangles, cubes, etc., such that when access is desired, at least one pair of previously unused character subsets not found in the same row or column of the matrix is chosen at random and transmitted by the computer. The proper response to gain access is transmittal of subsets which complete the rectangle, and/or a parallelepiped whose opposite corners were defined by first groups of code. Once used, subsets are not used again to absolutely defeat unauthorized access by eavesdropping, and the like.

  16. Dual operation characteristics of resistance random access memory in indium-gallium-zinc-oxide thin film transistors

    NASA Astrophysics Data System (ADS)

    Yang, Jyun-Bao; Chang, Ting-Chang; Huang, Jheng-Jie; Chen, Yu-Chun; Chen, Yu-Ting; Tseng, Hsueh-Chih; Chu, Ann-Kuo; Sze, Simon M.

    2014-04-01

    In this study, indium-gallium-zinc-oxide thin film transistors can be operated either as transistors or resistance random access memory devices. Before the forming process, current-voltage curve transfer characteristics are observed, and resistance switching characteristics are measured after a forming process. These resistance switching characteristics exhibit two behaviors, and are dominated by different mechanisms. The mode 1 resistance switching behavior is due to oxygen vacancies, while mode 2 is dominated by the formation of an oxygen-rich layer. Furthermore, an easy approach is proposed to reduce power consumption when using these resistance random access memory devices with the amorphous indium-gallium-zinc-oxide thin film transistor.

  17. Ferromagnetic alloy material CoFeC with high thermal tolerance in MgO/CoFeC/Pt structure and comparable intrinsic damping factor with CoFeB

    NASA Astrophysics Data System (ADS)

    Chen, Shaohai; Zhou, Jing; Lin, Weinan; Yu, Jihang; Guo, Rui; Poh, Francis; Shum, Danny; Chen, Jingsheng

    2018-02-01

    The thermal tolerance and perpendicular magnetic anisotropy (PMA) of ferromagnetic alloy Co40Fe40C20 in the structure MgO/CoFeC/Pt (or Ta) were investigated and compared with the commonly used CoFeB alloy. It is found that the PMA of CoFeC with {{K}i,CoFeC}=2.21 erg c{{m}-2} , which is 59% higher than that of CoFeB, can be obtained after proper post-annealing treatment. Furthermore, CoFeC alloy provides better thermal tolerance to temperature of 400 °C than CoFeB. The studies on ferromagnetic resonance show that the intrinsic damping constant α in of Co40Fe40C20 alloy is 0.0047, which is similar to the reported value of 0.004 for Co40Fe40B20 alloy. The comprehensive comparisons indicate that CoFeC alloy is a promising candidate for the application of the integration of spin torque transfer magnetic random access memory with complementary metal-oxide semiconductor processes.

  18. A multilevel nonvolatile magnetoelectric memory

    NASA Astrophysics Data System (ADS)

    Shen, Jianxin; Cong, Junzhuang; Shang, Dashan; Chai, Yisheng; Shen, Shipeng; Zhai, Kun; Sun, Young

    2016-09-01

    The coexistence and coupling between magnetization and electric polarization in multiferroic materials provide extra degrees of freedom for creating next-generation memory devices. A variety of concepts of multiferroic or magnetoelectric memories have been proposed and explored in the past decade. Here we propose a new principle to realize a multilevel nonvolatile memory based on the multiple states of the magnetoelectric coefficient (α) of multiferroics. Because the states of α depends on the relative orientation between magnetization and polarization, one can reach different levels of α by controlling the ratio of up and down ferroelectric domains with external electric fields. Our experiments in a device made of the PMN-PT/Terfenol-D multiferroic heterostructure confirm that the states of α can be well controlled between positive and negative by applying selective electric fields. Consequently, two-level, four-level, and eight-level nonvolatile memory devices are demonstrated at room temperature. This kind of multilevel magnetoelectric memory retains all the advantages of ferroelectric random access memory but overcomes the drawback of destructive reading of polarization. In contrast, the reading of α is nondestructive and highly efficient in a parallel way, with an independent reading coil shared by all the memory cells.

  19. Controllable morphology of flux avalanches in microstructured superconductors

    NASA Astrophysics Data System (ADS)

    Motta, M.; Colauto, F.; Vestgârden, J. I.; Fritzsche, J.; Timmermans, M.; Cuppens, J.; Attanasio, C.; Cirillo, C.; Moshchalkov, V. V.; Van de Vondel, J.; Johansen, T. H.; Ortiz, W. A.; Silhanek, A. V.

    2014-04-01

    The morphology of abrupt bursts of magnetic flux into superconducting films with engineered periodic pinning centers (antidots) has been investigated. Guided flux avalanches of thermomagnetic origin develop a treelike structure, with the main trunk perpendicular to the borders of the sample, while secondary branches follow well-defined directions determined by the geometrical details of the underlying periodic pinning landscape. Strikingly, we demonstrate that in a superconductor with relatively weak random pinning the morphology of such flux avalanches can be fully controlled by proper combinations of lattice symmetry and antidot geometry. Moreover, the resulting flux patterns can be reproduced, to the finest details, by simulations based on a phenomenological thermomagnetic model. In turn, this model can be used to predict such complex structures and to estimate physical variables of more difficult experimental access, such as the local values of temperature and electric field.

  20. Cognitive-behavioral therapy for obsessive–compulsive disorder: access to treatment, prediction of long-term outcome with neuroimaging

    PubMed Central

    O’Neill, Joseph; Feusner, Jamie D

    2015-01-01

    This article reviews issues related to a major challenge to the field for obsessive–compulsive disorder (OCD): improving access to cognitive-behavioral therapy (CBT). Patient-related barriers to access include the stigma of OCD and reluctance to take on the demands of CBT. Patient-external factors include the shortage of trained CBT therapists and the high costs of CBT. The second half of the review focuses on one partial, yet plausible aid to improve access – prediction of long-term response to CBT, particularly using neuroimaging methods. Recent pilot data are presented revealing a potential for pretreatment resting-state functional magnetic resonance imaging and magnetic resonance spectroscopy of the brain to forecast OCD symptom severity up to 1 year after completing CBT. PMID:26229514

  1. Lessons learned in research: an attempt to study the effects of magnetic therapy.

    PubMed

    Szor, Judy K; Holewinski, Paul

    2002-02-01

    Difficulties related to chronic wound healing research are frequently discussed, but results of less-than-perfect studies commonly are not published. A 16-week, randomized controlled double-blind study attempted to investigate the effect of static magnetic therapy on the healing of diabetic foot ulcers. Of 56 subjects, 37 completed the study. Because of the small sample size, randomization did not control for differences between the two groups, and the data could not be analyzed in any meaningful way. The challenges of performing magnetic therapy research are discussed and considerations for future studies are noted.

  2. Remote Teaching Experiments on Magnetic Domains in Thin Films

    ERIC Educational Resources Information Center

    Dobrogowski, W.; Maziewski, A.; Zablotskii, V.

    2007-01-01

    We describe our experience in building a remote laboratory for teaching magnetic domains. Fulfilling the proposed on-line experiments, students can observe and study magnetization processes that are often difficult to explain with written material. It is proposed that networks of remotely accessible laboratories could be integrated in the Global…

  3. Can Interdistrict Choice Boost Student Achievement? The Case of Connecticut's Interdistrict Magnet School Program

    ERIC Educational Resources Information Center

    Bifulco, Robert; Cobb, Casey D.; Bell, Courtney

    2009-01-01

    Connecticut's interdistrict magnet schools offer a model of choice-based desegregation that appears to satisfy current legal constraints. This study presents evidence that interdistrict magnet schools have provided students from Connecticut's central cities access to less racially and economically isolated educational environments and estimates…

  4. Plated wire random access memories

    NASA Technical Reports Server (NTRS)

    Gouldin, L. D.

    1975-01-01

    A program was conducted to construct 4096-work by 18-bit random access, NDRO-plated wire memory units. The memory units were subjected to comprehensive functional and environmental tests at the end-item level to verify comformance with the specified requirements. A technical description of the unit is given, along with acceptance test data sheets.

  5. Multi-component access to a commercially available weight loss program: A randomized controlled trial

    USDA-ARS?s Scientific Manuscript database

    This study examined weight loss between a community-based, intensive behavioral counseling program (Weight Watchers PointsPlus that included three treatment access modes and a self-help condition. A total of 292 participants were randomized to a Weight Watchers (WW; n=147) or a self-help condition (...

  6. Complementarity between entanglement-assisted and quantum distributed random access code

    NASA Astrophysics Data System (ADS)

    Hameedi, Alley; Saha, Debashis; Mironowicz, Piotr; Pawłowski, Marcin; Bourennane, Mohamed

    2017-05-01

    Collaborative communication tasks such as random access codes (RACs) employing quantum resources have manifested great potential in enhancing information processing capabilities beyond the classical limitations. The two quantum variants of RACs, namely, quantum random access code (QRAC) and the entanglement-assisted random access code (EARAC), have demonstrated equal prowess for a number of tasks. However, there do exist specific cases where one outperforms the other. In this article, we study a family of 3 →1 distributed RACs [J. Bowles, N. Brunner, and M. Pawłowski, Phys. Rev. A 92, 022351 (2015), 10.1103/PhysRevA.92.022351] and present its general construction of both the QRAC and the EARAC. We demonstrate that, depending on the function of inputs that is sought, if QRAC achieves the maximal success probability then EARAC fails to do so and vice versa. Moreover, a tripartite Bell-type inequality associated with the EARAC variants reveals the genuine multipartite nonlocality exhibited by our protocol. We conclude with an experimental realization of the 3 →1 distributed QRAC that achieves higher success probabilities than the maximum possible with EARACs for a number of tasks.

  7. Portable and Error-Free DNA-Based Data Storage.

    PubMed

    Yazdi, S M Hossein Tabatabaei; Gabrys, Ryan; Milenkovic, Olgica

    2017-07-10

    DNA-based data storage is an emerging nonvolatile memory technology of potentially unprecedented density, durability, and replication efficiency. The basic system implementation steps include synthesizing DNA strings that contain user information and subsequently retrieving them via high-throughput sequencing technologies. Existing architectures enable reading and writing but do not offer random-access and error-free data recovery from low-cost, portable devices, which is crucial for making the storage technology competitive with classical recorders. Here we show for the first time that a portable, random-access platform may be implemented in practice using nanopore sequencers. The novelty of our approach is to design an integrated processing pipeline that encodes data to avoid costly synthesis and sequencing errors, enables random access through addressing, and leverages efficient portable sequencing via new iterative alignment and deletion error-correcting codes. Our work represents the only known random access DNA-based data storage system that uses error-prone nanopore sequencers, while still producing error-free readouts with the highest reported information rate/density. As such, it represents a crucial step towards practical employment of DNA molecules as storage media.

  8. Two LANL laboratory astrophysics experiments

    NASA Astrophysics Data System (ADS)

    Intrator, Thomas; Weber, Thomas; Feng, Yan; Hutchinson, Trevor; Dunn, John; Akcay, Cihan

    2014-06-01

    Two laboratory experiments are described that have been built at Los Alamos (LANL) to gain access to a wide range of fundamental plasma physics issues germane to astro, space, and fusion plasmas. The over arching theme is magnetized plasma dynamics which includes significant currents, MHD forces and instabilities, magnetic field creation and annihilation, sheared flows and shocks. The Relaxation Scaling Experiment (RSX) creates current sheets and flux ropes that exhibit fully 3D dynamics, and can kink, bounce, merge and reconnect, shred, and reform in complicated ways. Recent movies from a large data set describe the 3D magnetic structure of a driven and dissipative single flux rope that spontaneously self saturates a kink instability. Examples of a coherent shear flow dynamo driven by colliding flux ropes will also be shown.The Magnetized Shock Experiment (MSX) uses Field reversed configuration (FRC) experimental hardware that forms and ejects FRCs at 150km/sec. This is sufficient to drive a collision less magnetized shock when stagnated into a mirror stopping field region with Alfven Mach number MA=3 so that super critical shocks can be studied. We are building a plasmoid accelerator to drive Mach numbers MA >> 3 to access solar wind and more exotic astrophysical regimes. Unique features of this experiment include access to parallel, oblique and perpendicular shocks, shock region much larger than ion gyro radii and ion inertial length, room for turbulence, and large magnetic and fluid Reynolds numbers.*DOE Office of Fusion Energy Sciences under LANS contract DE-AC52-06NA25396, NASA Geospace NNHIOA044I, Basic, Center for Magnetic Self Organization

  9. 3D vector distribution of the electro-magnetic fields on a random gold film

    NASA Astrophysics Data System (ADS)

    Canneson, Damien; Berini, Bruno; Buil, Stéphanie; Hermier, Jean-Pierre; Quélin, Xavier

    2018-05-01

    The 3D vector distribution of the electro-magnetic fields at the very close vicinity of the surface of a random gold film is studied. Such films are well known for their properties of light confinement and large fluctuations of local density of optical states. Using Finite-Difference Time-Domain simulations, we show that it is possible to determine the local orientation of the electro-magnetic fields. This allows us to obtain a complete characterization of the fields. Large fluctuations of their amplitude are observed as previously shown. Here, we demonstrate large variations of their direction depending both on the position on the random gold film, and on the distance to it. Such characterization could be useful for a better understanding of applications like the coupling of point-like dipoles to such films.

  10. Access Denied

    ERIC Educational Resources Information Center

    Villano, Matt

    2008-01-01

    Building access control (BAC)--a catchall phrase to describe the systems that control access to facilities across campus--has traditionally been handled with remarkably low-tech solutions: (1) manual locks; (2) electronic locks; and (3) ID cards with magnetic strips. Recent improvements have included smart cards and keyless solutions that make use…

  11. A Pilot Randomized Controlled Trial of the ACCESS Program: A Group Intervention to Improve Social, Adaptive Functioning, Stress Coping, and Self-Determination Outcomes in Young Adults with Autism Spectrum Disorder.

    PubMed

    Oswald, Tasha M; Winder-Patel, Breanna; Ruder, Steven; Xing, Guibo; Stahmer, Aubyn; Solomon, Marjorie

    2018-05-01

    The purpose of this pilot randomized controlled trial was to investigate the acceptability and efficacy of the Acquiring Career, Coping, Executive control, Social Skills (ACCESS) Program, a group intervention tailored for young adults with autism spectrum disorder (ASD) to enhance critical skills and beliefs that promote adult functioning, including social and adaptive skills, self-determination skills, and coping self-efficacy. Forty-four adults with ASD (ages 18-38; 13 females) and their caregivers were randomly assigned to treatment or waitlist control. Compared to controls, adults in treatment significantly improved in adaptive and self-determination skills, per caregiver report, and self-reported greater belief in their ability to access social support to cope with stressors. Results provide evidence for the acceptability and efficacy of the ACCESS Program.

  12. AVE-SESAME program for the REEDA System

    NASA Technical Reports Server (NTRS)

    Hickey, J. S.

    1981-01-01

    The REEDA system software was modified and improved to process the AVE-SESAME severe storm data. A random access file system for the AVE storm data was designed, tested, and implemented. The AVE/SESAME software was modified to incorporate the random access file input and to interface with new graphics hardware/software now available on the REEDA system. Software was developed to graphically display the AVE/SESAME data in the convention normally used by severe storm researchers. Software was converted to AVE/SESAME software systems and interfaced with existing graphics hardware/software available on the REEDA System. Software documentation was provided for existing AVE/SESAME programs underlining functional flow charts and interacting questions. All AVE/SESAME data sets in random access format was processed to allow developed software to access the entire AVE/SESAME data base. The existing software was modified to allow for processing of different AVE/SESAME data set types including satellite surface and radar data.

  13. Transport of Charged Particles in Turbulent Magnetic Fields

    NASA Astrophysics Data System (ADS)

    Parashar, T.; Subedi, P.; Sonsrettee, W.; Blasi, P.; Ruffolo, D. J.; Matthaeus, W. H.; Montgomery, D.; Chuychai, P.; Dmitruk, P.; Wan, M.; Chhiber, R.

    2017-12-01

    Magnetic fields permeate the Universe. They are found in planets, stars, galaxies, and the intergalactic medium. The magnetic field found in these astrophysical systems are usually chaotic, disordered, and turbulent. The investigation of the transport of cosmic rays in magnetic turbulence is a subject of considerable interest. One of the important aspects of cosmic ray transport is to understand their diffusive behavior and to calculate the diffusion coefficient in the presence of these turbulent fields. Research has most frequently concentrated on determining the diffusion coefficient in the presence of a mean magnetic field. Here, we will particularly focus on calculating diffusion coefficients of charged particles and magnetic field lines in a fully three-dimensional isotropic turbulent magnetic field with no mean field, which may be pertinent to many astrophysical situations. For charged particles in isotropic turbulence we identify different ranges of particle energy depending upon the ratio of the Larmor radius of the charged particle to the characteristic outer length scale of the turbulence. Different theoretical models are proposed to calculate the diffusion coefficient, each applicable to a distinct range of particle energies. The theoretical ideas are tested against results of detailed numerical experiments using Monte-Carlo simulations of particle propagation in stochastic magnetic fields. We also discuss two different methods of generating random magnetic field to study charged particle propagation using numerical simulation. One method is the usual way of generating random fields with a specified power law in wavenumber space, using Gaussian random variables. Turbulence, however, is non-Gaussian, with variability that comes in bursts called intermittency. We therefore devise a way to generate synthetic intermittent fields which have many properties of realistic turbulence. Possible applications of such synthetically generated intermittent fields are discussed.

  14. Probing the magnetic topologies of magnetic clouds by means of solar energetic particles

    NASA Technical Reports Server (NTRS)

    Kahler, S. W.; Reames, D. V.

    1991-01-01

    Solar energetic particles (SEPs) have been used as probes of magnetic cloud topologies. The rapid access of SEPs to the interiors of many clouds indicates that the cloud field lines extend back to the sun and hence are not plasmoids. The small modulation of galactic cosmic rays associated with clouds also suggests that the magnetic fields of clouds are not closed.

  15. Two LANL laboratory astrophysics experiments

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Intrator, Thomas P.

    2014-01-24

    Two laboratory experiments are described that have been built at Los Alamos (LANL) to gain access to a wide range of fundamental plasma physics issues germane to astro, space, and fusion plasmas. The overarching theme is magnetized plasma dynamics which includes significant currents, MHD forces and instabilities, magnetic field creation and annihilation, sheared flows and shocks. The Relaxation Scaling Experiment (RSX) creates current sheets and flux ropes that exhibit fully 3D dynamics, and can kink, bounce, merge and reconnect, shred, and reform in complicated ways. Recent movies from a large data set describe the 3D magnetic structure of a drivenmore » and dissipative single flux rope that spontaneously self-saturates a kink instability. Examples of a coherent shear flow dynamo driven by colliding flux ropes will also be shown. The Magnetized Shock Experiment (MSX) uses Field reversed configuration (FRC) experimental hardware that forms and ejects FRCs at 150km/sec. This is sufficient to drive a collision less magnetized shock when stagnated into a mirror stopping field region with Alfven Mach number MA=3 so that super critical shocks can be studied. We are building a plasmoid accelerator to drive Mach numbers MA >> 3 to access solar wind and more exotic astrophysical regimes. Unique features of this experiment include access to parallel, oblique and perpendicular shocks, shock region much larger than ion gyro radii and ion inertial length, room for turbulence, and large magnetic and fluid Reynolds numbers.« less

  16. Phonon and magnetic structure in δ-plutonium from density-functional theory

    DOE PAGES

    Söderlind, Per; Zhou, F.; Landa, A.; ...

    2015-10-30

    We present phonon properties of plutonium metal obtained from a combination of density-functional-theory (DFT) electronic structure and the recently developed compressive sensing lattice dynamics (CSLD). The CSLD model is here trained on DFT total energies of several hundreds of quasi-random atomic configurations for best possible accuracy of the phonon properties. The calculated phonon dispersions compare better with experiment than earlier results obtained from dynamical mean-field theory. The density-functional model of the electronic structure consists of disordered magnetic moments with all relativistic effects and explicit orbital-orbital correlations. The magnetic disorder is approximated in two ways: (i) a special quasi-random structure andmore » (ii) the disordered-local-moment (DLM) method within the coherent potential approximation. Magnetism in plutonium has been debated intensely, However, the present magnetic approach for plutonium is validated by the close agreement between the predicted magnetic form factor and that of recent neutron-scattering experiments.« less

  17. 47 CFR 51.217 - Nondiscriminatory access: Telephone numbers, operator services, directory assistance services...

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... to have access to its directory assistance services, including directory assistance databases, so... provider, including transfer of the LECs' directory assistance databases in readily accessible magnetic.... Updates to the directory assistance database shall be made in the same format as the initial transfer...

  18. 34 CFR 280.1 - What is the Magnet Schools Assistance Program?

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... schools; (e) Improvement of the capacity of LEAs, including through professional development, to continue... terminated; and (f) Ensuring that all students enrolled in the magnet school programs have equitable access... 34 Education 1 2012-07-01 2012-07-01 false What is the Magnet Schools Assistance Program? 280.1...

  19. 34 CFR 280.1 - What is the Magnet Schools Assistance Program?

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... schools; (e) Improvement of the capacity of LEAs, including through professional development, to continue... terminated; and (f) Ensuring that all students enrolled in the magnet school programs have equitable access... 34 Education 1 2014-07-01 2014-07-01 false What is the Magnet Schools Assistance Program? 280.1...

  20. 34 CFR 280.1 - What is the Magnet Schools Assistance Program?

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... schools; (e) Improvement of the capacity of LEAs, including through professional development, to continue... terminated; and (f) Ensuring that all students enrolled in the magnet school programs have equitable access... 34 Education 1 2013-07-01 2013-07-01 false What is the Magnet Schools Assistance Program? 280.1...

  1. First results of transcritical magnetized collisionless shock studies on MSX

    NASA Astrophysics Data System (ADS)

    Weber, T. E.; Smith, R. J.; Hutchinson, T. M.; Taylor, S. F.; Hsu, S. C.

    2014-10-01

    Magnetized collisionless shocks exhibit transitional length and time scales much shorter than can be created through collisional processes. They are common throughout the cosmos, but have historically proven difficult to create in the laboratory. The Magnetized Shock Experiment (MSX) at LANL produces super-Alfvénic shocks through the acceleration and subsequent stagnation of Field Reversed Configuration (FRC) plasmoids against a strong magnetic mirror and flux-conserving vacuum boundary. Plasma flows have been produced with sonic and Alfvén Mach numbers up to ~10 over a wide range of plasma beta with embedded perpendicular, oblique, and parallel magnetic field. Macroscopic ion skin-depth and long ion-gyroperiod enable diagnostic access to relevant shock physics using common methods. Variable plasmoid velocity, density, temperature, and magnetic field provide access to a wide range of shock conditions, and a campaign to study the physics of transcritical and supercritical shocks within the FRC plasmoid is currently underway. An overview of the experimental design, diagnostics suite, physics objectives, and recent results will be presented. Supported by DOE Office of Fusion Energy Sciences under DOE Contract DE-AC52-06NA25369.

  2. System and method of operating toroidal magnetic confinement devices

    DOEpatents

    Chance, Morrell S.; Jardin, Stephen C.; Stix, Thomas H.; Grimm, deceased, Ray C.; Manickam, Janardhan; Okabayashi, Michio

    1987-01-01

    For toroidal magnetic confinement devices the second region of stability against ballooning modes can be accessed with controlled operation. Under certain modes of operation, the first and second stability regions may be joined together. Accessing the second region of stability is accomplished by forming a bean-shaped plasma and increasing the indentation until a critical value of indentation is reached. A pusher coil, located at the inner-major-radius side of the device, is engaged to form a bean-shaped poloidal cross-section in the plasma.

  3. A Magneto-Inductive Sensor Based Wireless Tongue-Computer Interface

    PubMed Central

    Huo, Xueliang; Wang, Jia; Ghovanloo, Maysam

    2015-01-01

    We have developed a noninvasive, unobtrusive magnetic wireless tongue-computer interface, called “Tongue Drive,” to provide people with severe disabilities with flexible and effective computer access and environment control. A small permanent magnet secured on the tongue by implantation, piercing, or tissue adhesives, is utilized as a tracer to track the tongue movements. The magnetic field variations inside and around the mouth due to the tongue movements are detected by a pair of three-axial linear magneto-inductive sensor modules mounted bilaterally on a headset near the user’s cheeks. After being wirelessly transmitted to a portable computer, the sensor output signals are processed by a differential field cancellation algorithm to eliminate the external magnetic field interference, and translated into user control commands, which could then be used to access a desktop computer, maneuver a powered wheelchair, or control other devices in the user’s environment. The system has been successfully tested on six able-bodied subjects for computer access by defining six individual commands to resemble mouse functions. Results show that the Tongue Drive system response time for 87% correctly completed commands is 0.8 s, which yields to an information transfer rate of ~130 b/min. PMID:18990653

  4. Diffusion of strongly magnetized cosmic ray particles in a turbulent medium

    NASA Technical Reports Server (NTRS)

    Ptuskin, V. S.

    1985-01-01

    Cosmic ray (CR) propagation in a turbulent medium is usually considered in the diffusion approximation. Here, the diffusion equation is obtained for strongly magnetized particles in the general form. The influence of a large-scale random magnetic field on CR propagation in interstellar medium is discussed. Cosmic rays are assumed to propagate in a medium with a regular field H and an ensemble of random MHD waves. The energy density of waves on scales smaller than the free path 1 of CR particles is small. The collision integral of the general form which describes interaction between relativistic particles and waves in the quasilinear approximation is used.

  5. Making working memory work: the effects of extended practice on focus capacity and the processes of updating, forward access, and random access.

    PubMed

    Price, John M; Colflesh, Gregory J H; Cerella, John; Verhaeghen, Paul

    2014-05-01

    We investigated the effects of 10h of practice on variations of the N-Back task to investigate the processes underlying possible expansion of the focus of attention within working memory. Using subtractive logic, we showed that random access (i.e., Sternberg-like search) yielded a modest effect (a 50% increase in speed) whereas the processes of forward access (i.e., retrieval in order, as in a standard N-Back task) and updating (i.e., changing the contents of working memory) were executed about 5 times faster after extended practice. We additionally found that extended practice increased working memory capacity as measured by the size of the focus of attention for the forward-access task, but not for variations where probing was in random order. This suggests that working memory capacity may depend on the type of search process engaged, and that certain working-memory-related cognitive processes are more amenable to practice than others. Copyright © 2014 Elsevier B.V. All rights reserved.

  6. Identification of cultivars and validation of genetic relationships in Mangifera indica L. using RAPD markers.

    PubMed

    Schnell, R J; Ronning, C M; Knight, R J

    1995-02-01

    Twenty-five accessions of mango were examined for random amplified polymorphic DNA (RAPD) genetic markers with 80 10-mer random primers. Of the 80 primers screened, 33 did not amplify, 19 were monomorphic, and 28 gave reproducible, polymorphic DNA amplification patterns. Eleven primers were selected from the 28 for the study. The number of bands generated was primer- and genotype-dependent, and ranged from 1 to 10. No primer gave unique banding patterns for each of the 25 accessions; however, ten different combinations of 2 primer banding patterns produced unique fingerprints for each accession. A maternal half-sib (MHS) family was included among the 25 accessions to see if genetic relationships could be detected. RAPD data were used to generate simple matching coefficients, which were analyzed phenetically and by means of principal coordinate analysis (PCA). The MHS clustered together in both the phenetic and the PCA while the randomly selected accessions were scattered with no apparent pattern. The uses of RAPD analysis for Mangifera germ plasm classification and clonal identification are discussed.

  7. Using Geographic Information Systems and Spatial Analysis Methods to Assess Household Water Access and Sanitation Coverage in the SHINE Trial.

    PubMed

    Ntozini, Robert; Marks, Sara J; Mangwadu, Goldberg; Mbuya, Mduduzi N N; Gerema, Grace; Mutasa, Batsirai; Julian, Timothy R; Schwab, Kellogg J; Humphrey, Jean H; Zungu, Lindiwe I

    2015-12-15

    Access to water and sanitation are important determinants of behavioral responses to hygiene and sanitation interventions. We estimated cluster-specific water access and sanitation coverage to inform a constrained randomization technique in the SHINE trial. Technicians and engineers inspected all public access water sources to ascertain seasonality, function, and geospatial coordinates. Households and water sources were mapped using open-source geospatial software. The distance from each household to the nearest perennial, functional, protected water source was calculated, and for each cluster, the median distance and the proportion of households within <500 m and >1500 m of such a water source. Cluster-specific sanitation coverage was ascertained using a random sample of 13 households per cluster. These parameters were included as covariates in randomization to optimize balance in water and sanitation access across treatment arms at the start of the trial. The observed high variability between clusters in both parameters suggests that constraining on these factors was needed to reduce risk of bias. © The Author 2015. Published by Oxford University Press for the Infectious Diseases Society of America.

  8. Fast Magnetic Micropropellers with Random Shapes

    PubMed Central

    2015-01-01

    Studying propulsion mechanisms in low Reynolds number fluid has implications for many fields, ranging from the biology of motile microorganisms and the physics of active matter to micromixing in catalysis and micro- and nanorobotics. The propulsion of magnetic micropropellers can be characterized by a dimensionless speed, which solely depends on the propeller geometry for a given axis of rotation. However, this dependence has so far been only investigated for helical propeller shapes, which were assumed to be optimal. In order to explore a larger variety of shapes, we experimentally studied the propulsion properties of randomly shaped magnetic micropropellers. Surprisingly, we found that their dimensionless speeds are high on average, comparable to previously reported nanofabricated helical micropropellers. The highest dimensionless speed we observed is higher than that of any previously reported propeller moving in a low Reynolds number fluid, proving that physical random shape generation can be a viable optimization strategy. PMID:26383225

  9. Influence of structure of iron nanoparticles in aggregates on their magnetic properties

    PubMed Central

    2011-01-01

    Zero-valent iron nanoparticles rapidly aggregate. One of the reasons is magnetic forces among the nanoparticles. Magnetic field around particles is caused by composition of the particles. Their core is formed from zero-valent iron, and shell is a layer of magnetite. The magnetic forces contribute to attractive forces among the nanoparticles and that leads to increasing of aggregation of the nanoparticles. This effect is undesirable for decreasing of remediation properties of iron particles and limited transport possibilities. The aggregation of iron nanoparticles was established for consequent processes: Brownian motion, sedimentation, velocity gradient of fluid around particles and electrostatic forces. In our previous work, an introduction of influence of magnetic forces among particles on the aggregation was presented. These forces have significant impact on the rate of aggregation. In this article, a numerical computation of magnetic forces between an aggregate and a nanoparticle and between two aggregates is shown. It is done for random position of nanoparticles in an aggregate and random or arranged directions of magnetic polarizations and for structured aggregates with arranged vectors of polarizations. Statistical computation by Monte Carlo is done, and range of dominant area of magnetic forces around particles is assessed. PMID:21917152

  10. Online CBT life skills programme for low mood and anxiety: study protocol for a pilot randomized controlled trial.

    PubMed

    Williams, Christopher; McClay, Carrie-Anne; Martinez, Rebeca; Morrison, Jill; Haig, Caroline; Jones, Ray; Farrand, Paul

    2016-04-27

    Low mood is a common mental health problem with significant health consequences. Studies have shown that cognitive behavioural therapy (CBT) is an effective treatment for low mood and anxiety when delivered one-to-one by an expert practitioner. However, access to this talking therapy is often limited and waiting lists can be long, although a range of low-intensity interventions that can increase access to services are available. These include guided self-help materials delivered via books, classes and online packages. This project aims to pilot a randomized controlled trial of an online CBT-based life skills course with community-based individuals experiencing low mood and anxiety. Individuals with elevated symptoms of depression will be recruited directly from the community via online and newspaper advertisements. Participants will be remotely randomized to receive either immediate access or delayed access to the Living Life to the Full guided online CBT-based life skills package, with telephone or email support provided whilst they use the online intervention. The primary end point will be at 3 months post-randomization, at which point the delayed-access group will be offered the intervention. Levels of depression, anxiety, social functioning and satisfaction will be assessed. This pilot study will test the trial design, and ability to recruit and deliver the intervention. Drop-out rates will be assessed and the completion and acceptability of the package will be investigated. The study will also inform a sample size power calculation for a subsequent substantive randomized controlled trial. ISRCTN ISRCTN12890709.

  11. Response of Materials Subjected to Magnetic Fields

    DTIC Science & Technology

    2011-08-31

    is a superconducting Helmholtz coil capable of operating at up to 6 Tesla. Access to the high magnetic field at the center of the magnet is by...conducting sphere moves through the magnetic field gradient (0 to 4 Tesla over ~20cm) at low velocity (under the influence of gravity for 1 meter). Area...sphere moves through the magnetic field gradient (0 to 4 Tesla over ~20cm) at high velocity (under the influence of gravity for 1 meter). Figure 8

  12. Topology-selective jamming of fully-connected, code-division random-access networks

    NASA Technical Reports Server (NTRS)

    Polydoros, Andreas; Cheng, Unjeng

    1990-01-01

    The purpose is to introduce certain models of topology selective stochastic jamming and examine its impact on a class of fully-connected, spread-spectrum, slotted ALOHA-type random access networks. The theory covers dedicated as well as half-duplex units. The dominant role of the spatial duty factor is established, and connections with the dual concept of time selective jamming are discussed. The optimal choices of coding rate and link access parameters (from the users' side) and the jamming spatial fraction are numerically established for DS and FH spreading.

  13. Impact of selected magnetic fields on the therapeutic effect in patients with lumbar discopathy: A prospective, randomized, single-blinded, and placebo-controlled clinical trial.

    PubMed

    Taradaj, Jakub; Ozon, Marcin; Dymarek, Robert; Bolach, Bartosz; Walewicz, Karolina; Rosińczuk, Joanna

    2018-03-23

    Interdisciplinary physical therapy together with pharmacological treatment constitute conservative treatment strategies related to low back pain (LBP). There is still a lack of high quality studies aimed at an objective evaluation of physiotherapeutic procedures according to their effectiveness in LBP. The aim of this study is to carry out a prospective, randomized, single-blinded, and placebocontrolled clinical trial to evaluate the effectiveness of magnetic fields in discopathy-related LBP. A group of 177 patients was assessed for eligibility based on inclusion and exclusion criteria. In the end, 106 patients were randomly assigned into 5 comparative groups: A (n = 23; magnetic therapy: 10 mT, 50 Hz); B (n = 23; magnetic therapy: 5 mT, 50 Hz); C (n = 20; placebo magnetic therapy); D (n = 20; magnetic stimulation: 49.2 μT, 195 Hz); and E (n = 20; placebo magnetic stimulation). All patients were assessed using tests for pain intensity, degree of disability and range of motion. Also, postural stability was assessed using a stabilographic platform. In this study, positive changes in all clinical outcomes were demonstrated in group A (p < 0.05). The most effective clinical effect was observed for pain reduction (p < 0.05), improvement of the range of motion (p < 0.05) and functional ability of the spine (p <0.05). It is also worth noting that the effects in the majority of the measured indicators were mostly short-term (p > 0.05). It was determined that the application of magnetic therapy (10 mT, 50 Hz, 20 min) significantly reduces pain symptoms and leads to an improvement of functional ability in patients with LBP.

  14. System and method of operating toroidal magnetic confinement devices

    DOEpatents

    Chance, M.S.; Jardin, S.C.; Stix, T.H.; Grimm, R.C.; Manickam, J.; Okabayashi, M.

    1984-08-30

    This invention pertains to methods and arrangements for attaining high beta values in plasma confinement devices. More specifically, this invention pertains to methods for accessing the second stability region of operation in toroidal magnetic confinement devices.

  15. The Use of a Computer-Controlled Random Access Slide Projector for Rapid Information Display.

    ERIC Educational Resources Information Center

    Muller, Mark T.

    A 35mm random access slide projector operated in conjunction with a computer terminal was adapted to meet the need for a more rapid and complex graphic display mechanism than is currently available with teletypewriter terminals. The model projector can be operated manually to provide for a maintenance checkout of the electromechanical system.…

  16. 76 FR 45295 - In the Matter of Certain Static Random Access Memories and Products Containing Same; Notice of...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-07-28

    ... supplementing the amended complaint was filed on June 28, 2011. A second amended complaint was filed on July 13... of certain static random access memories and products containing same by reason of infringement of... 13 of the `937 patent, and whether an industry in the United States exists as required by subsection...

  17. High capacity low delay packet broadcasting multiaccess schemes for satellite repeater systems

    NASA Astrophysics Data System (ADS)

    Bose, S. K.

    1980-12-01

    Demand assigned packet radio schemes using satellite repeaters can achieve high capacities but often exhibit relatively large delays under low traffic conditions when compared to random access. Several schemes which improve delay performance at low traffic but which have high capacity are presented and analyzed. These schemes allow random acess attempts by users, who are waiting for channel assignments. The performance of these are considered in the context of a multiple point communication system carrying fixed length messages between geographically distributed (ground) user terminals which are linked via a satellite repeater. Channel assignments are done following a BCC queueing discipline by a (ground) central controller on the basis of requests correctly received over a collision type access channel. In TBACR Scheme A, some of the forward message channels are set aside for random access transmissions; the rest are used in a demand assigned mode. Schemes B and C operate all their forward message channels in a demand assignment mode but, by means of appropriate algorithms for trailer channel selection, allow random access attempts on unassigned channels. The latter scheme also introduces framing and slotting of the time axis to implement a more efficient algorithm for trailer channel selection than the former.

  18. Magnetoelectric effect in antiferromagnetic multiferroic Pb (F e1 /2N b1 /2)O3 and its solid solutions with PbTi O3

    NASA Astrophysics Data System (ADS)

    Laguta, V. V.; Stephanovich, V. A.; Raevski, I. P.; Raevskaya, S. I.; Titov, V. V.; Smotrakov, V. G.; Eremkin, V. V.

    2017-01-01

    Antiferromagnets (AFMs) are presently considered as promising materials for applications in spintronics and random access memories due to the robustness of information stored in the AFM state against perturbing magnetic fields. In this respect, AFM multiferroics may be attractive alternatives for conventional AFMs as the coupling of magnetism with ferroelectricity (magnetoelectric effect) offers an elegant possibility of electric-field control and switching of AFM domains. Here we report the results of comprehensive experimental and theoretical investigations of the quadratic magnetoelectric (ME) effect in single crystals and highly resistive ceramics of Pb (F e1 /2N b1 /2)O3 (PFN) and (1 -x ) Pb (F e1 /2N b1 /2) O3-x PbTi O3(PFN -x PT ) . We are interested primarily in the temperature range of the multiferroic phase, T <150 K , where the ME coupling coefficient is extremely large (as compared to the well-known multiferroic BiFe O3 ) and shows sign reversal at the paramagnetic-to-antiferromagnetic phase transition. Moreover, we observe strong ME response nonlinearity in the AFM phase in the magnetic fields of only a few kOe. To describe the temperature and magnetic field dependencies of the above unusual features of the ME effect in PFN and PFN-x PT , we use a simple phenomenological Landau approach which explains experimental data surprisingly well. Our ME measurements demonstrate that the electric field of only 20-25 kV/cm is able to switch the AFM domains and align them with ferroelectric ones even in PFN ceramic samples.

  19. Evaluation of pulsing magnetic field effects on paresthesia in multiple sclerosis patients, a randomized, double-blind, parallel-group clinical trial.

    PubMed

    Afshari, Daryoush; Moradian, Nasrin; Khalili, Majid; Razazian, Nazanin; Bostani, Arash; Hoseini, Jamal; Moradian, Mohamad; Ghiasian, Masoud

    2016-10-01

    Evidence is mounting that magnet therapy could alleviate the symptoms of multiple sclerosis (MS). This study was performed to test the effects of the pulsing magnetic fields on the paresthesia in MS patients. This study has been conducted as a randomized, double-blind, parallel-group clinical trial during the April 2012 to October 2013. The subjects were selected among patients referred to MS clinic of Imam Reza Hospital; affiliated to Kermanshah University of Medical Sciences, Iran. Sixty three patients with MS were included in the study and randomly were divided into two groups, 35 patients were exposed to a magnetic pulsing field of 4mT intensity and 15-Hz frequency sinusoidal wave for 20min per session 2 times per week over a period of 2 months involving 16 sessions and 28 patients was exposed to a magnetically inactive field (placebo) for 20min per session 2 times per week over a period of 2 months involving 16 sessions. The severity of paresthesia was measured by the numerical rating scale (NRS) at 30, 60days. The study primary end point was NRS change between baseline and 60days. The secondary outcome was NRS change between baseline and 30days. Patients exposing to magnetic field showed significant paresthesia improvement compared with the group of patients exposing to placebo. According to our results pulsed magnetic therapy could alleviate paresthesia in MS patients .But trials with more patients and longer duration are mandatory to describe long-term effects. Copyright © 2016 Elsevier B.V. All rights reserved.

  20. Assessment of wadeable stream resources in the driftless area ecoregion in Western Wisconsin using a probabilistic sampling design.

    PubMed

    Miller, Michael A; Colby, Alison C C; Kanehl, Paul D; Blocksom, Karen

    2009-03-01

    The Wisconsin Department of Natural Resources (WDNR), with support from the U.S. EPA, conducted an assessment of wadeable streams in the Driftless Area ecoregion in western Wisconsin using a probabilistic sampling design. This ecoregion encompasses 20% of Wisconsin's land area and contains 8,800 miles of perennial streams. Randomly-selected stream sites (n = 60) equally distributed among stream orders 1-4 were sampled. Watershed land use, riparian and in-stream habitat, water chemistry, macroinvertebrate, and fish assemblage data were collected at each true random site and an associated "modified-random" site on each stream that was accessed via a road crossing nearest to the true random site. Targeted least-disturbed reference sites (n = 22) were also sampled to develop reference conditions for various physical, chemical, and biological measures. Cumulative distribution function plots of various measures collected at the true random sites evaluated with reference condition thresholds, indicate that high proportions of the random sites (and by inference the entire Driftless Area wadeable stream population) show some level of degradation. Study results show no statistically significant differences between the true random and modified-random sample sites for any of the nine physical habitat, 11 water chemistry, seven macroinvertebrate, or eight fish metrics analyzed. In Wisconsin's Driftless Area, 79% of wadeable stream lengths were accessible via road crossings. While further evaluation of the statistical rigor of using a modified-random sampling design is warranted, sampling randomly-selected stream sites accessed via the nearest road crossing may provide a more economical way to apply probabilistic sampling in stream monitoring programs.

  1. CMOS-compatible spintronic devices: a review

    NASA Astrophysics Data System (ADS)

    Makarov, Alexander; Windbacher, Thomas; Sverdlov, Viktor; Selberherr, Siegfried

    2016-11-01

    For many decades CMOS devices have been successfully scaled down to achieve higher speed and increased performance of integrated circuits at lower cost. Today’s charge-based CMOS electronics encounters two major challenges: power dissipation and variability. Spintronics is a rapidly evolving research and development field, which offers a potential solution to these issues by introducing novel ‘more than Moore’ devices. Spin-based magnetoresistive random-access memory (MRAM) is already recognized as one of the most promising candidates for future universal memory. Magnetic tunnel junctions, the main elements of MRAM cells, can also be used to build logic-in-memory circuits with non-volatile storage elements on top of CMOS logic circuits, as well as versatile compact on-chip oscillators with low power consumption. We give an overview of CMOS-compatible spintronics applications. First, we present a brief introduction to the physical background considering such effects as magnetoresistance, spin-transfer torque (STT), spin Hall effect, and magnetoelectric effects. We continue with a comprehensive review of the state-of-the-art spintronic devices for memory applications (STT-MRAM, domain wall-motion MRAM, and spin-orbit torque MRAM), oscillators (spin torque oscillators and spin Hall nano-oscillators), logic (logic-in-memory, all-spin logic, and buffered magnetic logic gate grid), sensors, and random number generators. Devices with different types of resistivity switching are analyzed and compared, with their advantages highlighted and challenges revealed. CMOS-compatible spintronic devices are demonstrated beginning with predictive simulations, proceeding to their experimental confirmation and realization, and finalized by the current status of application in modern integrated systems and circuits. We conclude the review with an outlook, where we share our vision on the future applications of the prospective devices in the area.

  2. Spatial versus sequential correlations for random access coding

    NASA Astrophysics Data System (ADS)

    Tavakoli, Armin; Marques, Breno; Pawłowski, Marcin; Bourennane, Mohamed

    2016-03-01

    Random access codes are important for a wide range of applications in quantum information. However, their implementation with quantum theory can be made in two very different ways: (i) by distributing data with strong spatial correlations violating a Bell inequality or (ii) using quantum communication channels to create stronger-than-classical sequential correlations between state preparation and measurement outcome. Here we study this duality of the quantum realization. We present a family of Bell inequalities tailored to the task at hand and study their quantum violations. Remarkably, we show that the use of spatial and sequential quantum correlations imposes different limitations on the performance of quantum random access codes: Sequential correlations can outperform spatial correlations. We discuss the physics behind the observed discrepancy between spatial and sequential quantum correlations.

  3. ONR Far East Scientific Bulletin, Volume 7, Number 4, October-December 1982,

    DTIC Science & Technology

    1982-12-01

    transition metal compounds (2), - ESR and relaxation (3), - rare earth and actinides (3), - magnetics and superconductivity (3), - transition metal...34Itinerant Electron Magnetism ," by T. Moriya, - "Organic Superconductivity ," by D. Jerome, and - "Recent Developments in Solid Earth Sciences," by...compounds, low dimension systems, random systems, surface magnetism , magnetism and superconductivity , Kondo problem, diamagnetism and nuclear

  4. Remanent Magnetization: Signature of Many-Body Localization in Quantum Antiferromagnets

    NASA Astrophysics Data System (ADS)

    Ros, V.; Müller, M.

    2017-06-01

    We study the remanent magnetization in antiferromagnetic, many-body localized quantum spin chains, initialized in a fully magnetized state. Its long time limit is an order parameter for the localization transition, which is readily accessible by standard experimental probes in magnets. We analytically calculate its value in the strong-disorder regime exploiting the explicit construction of quasilocal conserved quantities of the localized phase. We discuss analogies in cold atomic systems.

  5. Stochastic Fermi Energization of Coronal Plasma during Explosive Magnetic Energy Release

    NASA Astrophysics Data System (ADS)

    Pisokas, Theophilos; Vlahos, Loukas; Isliker, Heinz; Tsiolis, Vassilis; Anastasiadis, Anastasios

    2017-02-01

    The aim of this study is to analyze the interaction of charged particles (ions and electrons) with randomly formed particle scatterers (e.g., large-scale local “magnetic fluctuations” or “coherent magnetic irregularities”) using the setup proposed initially by Fermi. These scatterers are formed by the explosive magnetic energy release and propagate with the Alfvén speed along the irregular magnetic fields. They are large-scale local fluctuations (δB/B ≈ 1) randomly distributed inside the unstable magnetic topology and will here be called Alfvénic Scatterers (AS). We constructed a 3D grid on which a small fraction of randomly chosen grid points are acting as AS. In particular, we study how a large number of test particles evolves inside a collection of AS, analyzing the evolution of their energy distribution and their escape-time distribution. We use a well-established method to estimate the transport coefficients directly from the trajectories of the particles. Using the estimated transport coefficients and solving the Fokker-Planck equation numerically, we can recover the energy distribution of the particles. We have shown that the stochastic Fermi energization of mildly relativistic and relativistic plasma can heat and accelerate the tail of the ambient particle distribution as predicted by Parker & Tidman and Ramaty. The temperature of the hot plasma and the tail of the energetic particles depend on the mean free path (λsc) of the particles between the scatterers inside the energization volume.

  6. Radiation Effects of Commercial Resistive Random Access Memories

    NASA Technical Reports Server (NTRS)

    Chen, Dakai; LaBel, Kenneth A.; Berg, Melanie; Wilcox, Edward; Kim, Hak; Phan, Anthony; Figueiredo, Marco; Buchner, Stephen; Khachatrian, Ani; Roche, Nicolas

    2014-01-01

    We present results for the single-event effect response of commercial production-level resistive random access memories. We found that the resistive memory arrays are immune to heavy ion-induced upsets. However, the devices were susceptible to single-event functional interrupts, due to upsets from the control circuits. The intrinsic radiation tolerant nature of resistive memory makes the technology an attractive consideration for future space applications.

  7. Vertical Launch System Loadout Planner

    DTIC Science & Technology

    2015-03-01

    United States Navy USS United States’ Ship VBA Visual Basic for Applications VLP VLS Loadout Planner VLS Vertical Launch System...with 32 gigabytes of random access memory and eight processors, General Algebraic Modeling System (GAMS) CPLEX version 24 (GAMS, 2015) solves this...problem in ten minutes to an integer tolerance of 10%. The GAMS interpreter and CPLEX solver require 75 Megabytes of random access memory for this

  8. High Productivity Computing Systems Analysis and Performance

    DTIC Science & Technology

    2005-07-01

    cubic grid Discrete Math Global Updates per second (GUP/S) RandomAccess Paper & Pencil Contact Bob Lucas (ISI) Multiple Precision none...can be found at the web site. One of the HPCchallenge codes, RandomAccess, is derived from the HPCS discrete math benchmarks that we released, and...Kernels Discrete Math … Graph Analysis … Linear Solvers … Signal Processi ng Execution Bounds Execution Indicators 6 Scalable Compact

  9. 10 CFR 26.67 - Random drug and alcohol testing of individuals who have applied for authorization.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... for one or more random tests after any applicable requirement for pre-access testing in §§ 26.65 or 26... individual for any pre-access testing that may be required under §§ 26.65 or 26.69, and thereafter, the... other entity relies on drug and alcohol tests that were conducted before the individual applied for...

  10. 10 CFR 26.67 - Random drug and alcohol testing of individuals who have applied for authorization.

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... for one or more random tests after any applicable requirement for pre-access testing in § 26.65 or... individual for any pre-access testing that may be required under § 26.65 or § 26.69, and thereafter, the... other entity relies on drug and alcohol tests that were conducted before the individual applied for...

  11. 10 CFR 26.67 - Random drug and alcohol testing of individuals who have applied for authorization.

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... for one or more random tests after any applicable requirement for pre-access testing in §§ 26.65 or 26... individual for any pre-access testing that may be required under §§ 26.65 or 26.69, and thereafter, the... other entity relies on drug and alcohol tests that were conducted before the individual applied for...

  12. 10 CFR 26.67 - Random drug and alcohol testing of individuals who have applied for authorization.

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... for one or more random tests after any applicable requirement for pre-access testing in §§ 26.65 or 26... individual for any pre-access testing that may be required under §§ 26.65 or 26.69, and thereafter, the... other entity relies on drug and alcohol tests that were conducted before the individual applied for...

  13. Anti-site mixing and magnetic properties of Fe 3Co 3Nb 2 studied via neutron powder diffraction

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Xu, Xiaoshan; Zhang, Xiaozhe; Yin, Yuewei

    Here, we studied the crystal structure and magnetic properties of the rare-earth-free intermetallic compound Fe 3Co 3Nb 2, which has recently been demonstrated to have potentially high magnetic anisotropy, using temperature-dependent neutron powder diffraction. Furthermore, the temperature dependence of the diffraction spectra reveals a magnetic transition between 300 and 400 K, in agreement with the magnetometry measurements. According to the structural refinement of the paramagnetic state and the substantial magnetic contribution to the diffuse scattering in the ferromagnetic state, the Fe/Co anti-site mixing is so strong that the site occupation for Fe and Co is almost random. The projection ofmore » the magnetic moments turned out to be non-zero along the c axis and in the a–b plane of Fe 3Co 3Nb 2, most likely because of the exchange interactions between the randomly orientated nanograins in the samples. These findings suggest that future studies on the magnetism of Fe 3Co 3Nb 2 need to take the Fe/Co anti-site mixing into account, and the exchange interactions need to be suppressed to obtain large remanence and coercivity.« less

  14. Anti-site mixing and magnetic properties of Fe 3Co 3Nb 2 studied via neutron powder diffraction

    DOE PAGES

    Xu, Xiaoshan; Zhang, Xiaozhe; Yin, Yuewei; ...

    2016-11-02

    Here, we studied the crystal structure and magnetic properties of the rare-earth-free intermetallic compound Fe 3Co 3Nb 2, which has recently been demonstrated to have potentially high magnetic anisotropy, using temperature-dependent neutron powder diffraction. Furthermore, the temperature dependence of the diffraction spectra reveals a magnetic transition between 300 and 400 K, in agreement with the magnetometry measurements. According to the structural refinement of the paramagnetic state and the substantial magnetic contribution to the diffuse scattering in the ferromagnetic state, the Fe/Co anti-site mixing is so strong that the site occupation for Fe and Co is almost random. The projection ofmore » the magnetic moments turned out to be non-zero along the c axis and in the a–b plane of Fe 3Co 3Nb 2, most likely because of the exchange interactions between the randomly orientated nanograins in the samples. These findings suggest that future studies on the magnetism of Fe 3Co 3Nb 2 need to take the Fe/Co anti-site mixing into account, and the exchange interactions need to be suppressed to obtain large remanence and coercivity.« less

  15. Self-taught axillary vein access without venography for pacemaker implantation: prospective randomized comparison with the cephalic vein access.

    PubMed

    Squara, Fabien; Tomi, Julien; Scarlatti, Didier; Theodore, Guillaume; Moceri, Pamela; Ferrari, Emile

    2017-12-01

    Axillary vein access for pacemaker implantation is uncommon in many centres because of the lack of training in this technique. We assessed whether the introduction of the axillary vein technique was safe and efficient as compared with cephalic vein access, in a centre where no operators had any previous experience in axillary vein puncture. Patients undergoing pacemaker implantation were randomized to axillary or cephalic vein access. All three operators had no experience nor training in axillary vein puncture, and self-learned the technique by reading a published review. Axillary vein puncture was fluoroscopy-guided without contrast venography. Cephalic access was performed by dissection of delto-pectoral groove. Venous access success, venous access duration (from skin incision to guidewire or lead in superior vena cava), procedure duration, X-ray exposure, and peri-procedural (1 month) complications were recorded. results We randomized 74 consecutive patients to axillary (n = 37) or cephalic vein access (n = 37). Axillary vein was successfully accessed in 30/37 (81.1%) patients vs. 28/37 (75.7%) of cephalic veins (P = 0.57). Venous access time was shorter in axillary group than in cephalic group [5.7 (4.4-8.3) vs. 12.2 (10.5-14.8) min, P < 0.001], as well as procedure duration [34.8 (30.6-38.4) vs. 42.0 (39.1-46.6) min, P = 0.043]. X-ray exposure and peri-procedural overall complications were comparable in both groups. Axillary puncture was safe and faster than cephalic access even for the five first procedures performed by each operator. Self-taught axillary vein puncture for pacemaker implantation seems immediately safe and faster than cephalic vein access, when performed by electrophysiologists trained to pacemaker implantation but not to axillary vein puncture. Published on behalf of the European Society of Cardiology. All rights reserved. © The Author 2017. For Permissions, please email: journals.permissions@oup.com.

  16. Magnetic orientation of nontronite clay in aqueous dispersions and its effect on water diffusion.

    PubMed

    Abrahamsson, Christoffer; Nordstierna, Lars; Nordin, Matias; Dvinskikh, Sergey V; Nydén, Magnus

    2015-01-01

    The diffusion rate of water in dilute clay dispersions depends on particle concentration, size, shape, aggregation and water-particle interactions. As nontronite clay particles magnetically align parallel to the magnetic field, directional self-diffusion anisotropy can be created within such dispersion. Here we study water diffusion in exfoliated nontronite clay dispersions by diffusion NMR and time-dependant 1H-NMR-imaging profiles. The dispersion clay concentration was varied between 0.3 and 0.7 vol%. After magnetic alignment of the clay particles in these dispersions a maximum difference of 20% was measured between the parallel and perpendicular self-diffusion coefficients in the dispersion with 0.7 vol% clay. A method was developed to measure water diffusion within the dispersion in the absence of a magnetic field (random clay orientation) as this is not possible with standard diffusion NMR. However, no significant difference in self-diffusion coefficient between random and aligned dispersions could be observed. Copyright © 2014 Elsevier Inc. All rights reserved.

  17. Accessible magnetic resonance imaging.

    PubMed

    Kaufman, L; Arakawa, M; Hale, J; Rothschild, P; Carlson, J; Hake, K; Kramer, D; Lu, W; Van Heteren, J

    1989-10-01

    The cost of magnetic resonance imaging (MRI) is driven by magnetic field strength. Misperceptions as to the impact of field strength on performance have led to systems that are more expensive than they need to be. Careful analysis of all the factors that affect diagnostic quality lead to the conclusion that field strength per se is not a strong determinant of system performance. Freed from the constraints imposed by high-field operation, it is possible to exploit a varied set of opportunities afforded by low-field operation. In addition to lower costs and easier siting, we can take advantage of shortened T1 times, higher contrast, reduced sensitivity to motion, and reduced radiofrequency power deposition. These conceptual advantages can be made to coalesce onto practical imaging systems. We describe a low-cost MRI system that utilizes a permanent magnet of open design. Careful optimization of receiving antennas and acquisition sequences permit performance levels consistent with those needed for an effective diagnostic unit. Ancillary advantages include easy access to the patient, reduced claustrophobia, quiet and comfortable operation, and absence of a missile effect. The system can be sited in 350 sq ft and consumes a modest amount of electricity. MRI equipment of this kind can widen the population base than can access this powerful and beneficial diagnostic modality.

  18. Magnetic stripes and skyrmions with helicity reversals.

    PubMed

    Yu, Xiuzhen; Mostovoy, Maxim; Tokunaga, Yusuke; Zhang, Weizhu; Kimoto, Koji; Matsui, Yoshio; Kaneko, Yoshio; Nagaosa, Naoto; Tokura, Yoshinori

    2012-06-05

    It was recently realized that topological spin textures do not merely have mathematical beauty but can also give rise to unique functionalities of magnetic materials. An example is the skyrmion--a nano-sized bundle of noncoplanar spins--that by virtue of its nontrivial topology acts as a flux of magnetic field on spin-polarized electrons. Lorentz transmission electron microscopy recently emerged as a powerful tool for direct visualization of skyrmions in noncentrosymmetric helimagnets. Topologically, skyrmions are equivalent to magnetic bubbles (cylindrical domains) in ferromagnetic thin films, which were extensively explored in the 1970s for data storage applications. In this study we use Lorentz microscopy to image magnetic domain patterns in the prototypical magnetic oxide-M-type hexaferrite with a hint of scandium. Surprisingly, we find that the magnetic bubbles and stripes in the hexaferrite have a much more complex structure than the skyrmions and spirals in helimagnets, which we associate with the new degree of freedom--helicity (or vector spin chirality) describing the direction of spin rotation across the domain walls. We observe numerous random reversals of helicity in the stripe domain state. Random helicity of cylindrical domain walls coexists with the positional order of magnetic bubbles in a triangular lattice. Most unexpectedly, we observe regular helicity reversals inside skyrmions with an unusual multiple-ring structure.

  19. Demagnetization Treatment of Remanent Composite Microspheres Studied by Alternating Current Susceptibility Measurements

    PubMed Central

    van Berkum, Susanne; Erné, Ben H.

    2013-01-01

    The magnetic remanence of silica microspheres with a low concentration of embedded cobalt ferrite nanoparticles is studied after demagnetization and remagnetization treatments. When the microspheres are dispersed in a liquid, alternating current (AC) magnetic susceptibility spectra reveal a constant characteristic frequency, corresponding to the rotational diffusion of the microparticles; this depends only on particle size and liquid viscosity, making the particles suitable as a rheological probe and indicating that interactions between the microspheres are weak. On the macroscopic scale, a sample with the dry microparticles is magnetically remanent after treatment in a saturating field, and after a demagnetization treatment, the remanence goes down to zero. The AC susceptibility of a liquid dispersion, however, characterizes the remanence on the scale of the individual microparticles, which does not become zero after demagnetization. The reason is that an individual microparticle contains only a relatively small number of magnetic units, so that even if they can be reoriented magnetically at random, the average vector sum of the nanoparticle dipoles is not negligible on the scale of the microparticle. In contrast, on the macroscopic scale, the demagnetization procedure randomizes the orientations of a macroscopic number of magnetic units, resulting in a remanent magnetization that is negligible compared to the saturation magnetization of the entire sample. PMID:24009021

  20. Fabrication and properties of nanoscale multiferroic heterostructures for application in magneto-electric random access memory (MERAM) devices

    NASA Astrophysics Data System (ADS)

    Kim, Gunwoo

    Magnetoelectric random access memory (MERAM) has emerged as a promising new class of non-volatile solid-state memory device. It offers nondestructive reading along with low power consumption during the write operation. A common implementation of MERAM involves use of multiferroic tunneling junctions (MFTJs), which besides offering non-volatility are both electrically and magnetically tunable. Fundamentally, a MFTJ consists of a heterostructure of an ultrathin multiferroic or ferroelectric material as the active tunneling barrier sandwiched between ferromagnetic electrodes. Thereby, the MFTJ exhibits both tunnel electroresistance (TER) and tunnel magnetoresistance (TMR) effects with application of an electric and magnetic field, respectively. In this thesis work, we have developed two-dimensional (2D) thin-film multiferroic heterostructure METJ prototypes consisting of ultrathin ferroelectric BaTiO3 (BTO) layer and a conducting ferromagnetic La0.67Sr 0.33MnO3 (LSMO) electrode. The heteroepitaxial films are grown using the pulsed laser deposition (PLD) technique. This oxide heterostructure offers the opportunity to study the nano-scale details of the tunnel electroresistance (TER) effect using scanning probe microscopy techniques. We performed the measurements using the MFP-3D (Asylum Research) scanning probe microscope. The ultrathin BTO films (1.2-2.0 nm) grown on LSMO electrodes display both ferro- and piezo-electric properties and exhibit large tunnel resistance effect. We have explored the growth and properties of one-dimensional (1D) heterostructures, referred to as multiferoric nanowire (NW) heterostructures. The ferromagnetic/ferroelectric composite heterostructures are grown as sheath layers using PLD on lattice-matched template NWs, e.g. MgO, that are deposited by chemical vapor deposition utilizing the vapor-liquid-solid (VLS) mechanism. The one-dimensional geometry can substantially overcome the clamping effect of the substrate present in two-dimensional structures because of the reduced volume of the template. This leads to minimum constraint of displacements at the interface and thereby significantly enhances the magnetoelectric (ME) effect. We characterized the nanostructures using scanning electron microscopy (SEM) and transmission electron microscopy (TEM). The results of our studies utilizing multiferroic 2-D thin films and 1-D NW architectures clearly demonstrate the potential of these heterostructures for future device applications, such as in MERAM, data storage, magneto-electric field sensors, etc.

  1. A novel ternary content addressable memory design based on resistive random access memory with high intensity and low search energy

    NASA Astrophysics Data System (ADS)

    Han, Runze; Shen, Wensheng; Huang, Peng; Zhou, Zheng; Liu, Lifeng; Liu, Xiaoyan; Kang, Jinfeng

    2018-04-01

    A novel ternary content addressable memory (TCAM) design based on resistive random access memory (RRAM) is presented. Each TCAM cell consists of two parallel RRAM to both store and search for ternary data. The cell size of the proposed design is 8F2, enable a ∼60× cell area reduction compared with the conventional static random access memory (SRAM) based implementation. Simulation results also show that the search delay and energy consumption of the proposed design at the 64-bit word search are 2 ps and 0.18 fJ/bit/search respectively at 22 nm technology node, where significant improvements are achieved compared to previous works. The desired characteristics of RRAM for implementation of the high performance TCAM search chip are also discussed.

  2. Random-access optical-resolution photoacoustic microscopy using a digital micromirror device

    PubMed Central

    Liang, Jinyang; Zhou, Yong; Winkler, Amy W.; Wang, Lidai; Maslov, Konstantin I.; Li, Chiye; Wang, Lihong V.

    2013-01-01

    We developed random-access optical-resolution photoacoustic microscopy using a digital micromirror device. This system can rapidly scan arbitrarily shaped regions of interest within a 40×40 μm2 imaging area with a lateral resolution of 3.6 μm. To identify a region of interest, a global structural image is first acquired, then the selected region is scanned. The random-access ability was demonstrated by imaging two static samples, a carbon fiber cross and a monolayer of red blood cells, with an acquisition rate up to 4 kilohertz. The system was then used to monitor blood flow in vivo in real time within user-selected capillaries in a mouse ear. By imaging only the capillary of interest, the frame rate was increased by up to 9.2 times. PMID:23903111

  3. Random-access optical-resolution photoacoustic microscopy using a digital micromirror device.

    PubMed

    Liang, Jinyang; Zhou, Yong; Winkler, Amy W; Wang, Lidai; Maslov, Konstantin I; Li, Chiye; Wang, Lihong V

    2013-08-01

    We developed random-access optical-resolution photoacoustic microscopy using a digital micromirror device. This system can rapidly scan arbitrarily shaped regions of interest within a 40 μm×40 μm imaging area with a lateral resolution of 3.6 μm. To identify a region of interest, a global structural image is first acquired, then the selected region is scanned. The random-access ability was demonstrated by imaging two static samples, a carbon fiber cross and a monolayer of red blood cells, with an acquisition rate up to 4 kHz. The system was then used to monitor blood flow in vivo in real time within user-selected capillaries in a mouse ear. By imaging only the capillary of interest, the frame rate was increased by up to 9.2 times.

  4. Design of a Vertical Composite Thin Film System with Ultralow Leakage To Yield Large Converse Magnetoelectric Effect.

    PubMed

    Wu, Rui; Kursumovic, Ahmed; Gao, Xingyao; Yun, Chao; Vickers, Mary E; Wang, Haiyan; Cho, Seungho; MacManus-Driscoll, Judith L

    2018-05-30

    Electric field control of magnetism is a critical future technology for low-power, ultrahigh density memory. However, despite intensive research efforts, no practical material systems have emerged. Interface-coupled, composite systems containing ferroelectric and ferri-/ferromagnetic elements have been widely explored, but they have a range of problems, for example, substrate clamping, large leakage, and inability to miniaturize. In this work, through careful material selection, design, and nanoengineering, a high-performance room-temperature magnetoelectric system is demonstrated. The clamping problem is overcome by using a vertically aligned nanocomposite structure in which the strain coupling is independent of the substrate. To overcome the leakage problem, three key novel advances are introduced: a low leakage ferroelectric, Na 0.5 Bi 0.5 TiO 3 ; ferroelectric-ferrimagnetic vertical interfaces which are not conducting; and current blockage via a rectifying interface between the film and the Nb-doped SrTiO 3 substrate. The new multiferroic nanocomposite (Na 0.5 Bi 0.5 TiO 3 -CoFe 2 O 4 ) thin-film system enables, for the first time, large-scale in situ electric field control of magnetic anisotropy at room temperature in a system applicable for magnetoelectric random access memory, with a magnetoelectric coefficient of 1.25 × 10 -9 s m -1 .

  5. Real-time functional magnetic resonance imaging neurofeedback in motor neurorehabilitation.

    PubMed

    Linden, David E J; Turner, Duncan L

    2016-08-01

    Recent developments in functional magnetic resonance imaging (fMRI) have catalyzed a new field of translational neuroscience. Using fMRI to monitor the aspects of task-related changes in neural activation or brain connectivity, investigators can offer feedback of simple or complex neural signals/patterns back to the participant on a quasireal-time basis [real-time-fMRI-based neurofeedback (rt-fMRI-NF)]. Here, we introduce some background methodology of the new developments in this field and give a perspective on how they may be used in neurorehabilitation in the future. The development of rt-fMRI-NF has been used to promote self-regulation of activity in several brain regions and networks. In addition, and unlike other noninvasive techniques, rt-fMRI-NF can access specific subcortical regions and in principle any region that can be monitored using fMRI including the cerebellum, brainstem and spinal cord. In Parkinson's disease and stroke, rt-fMRI-NF has been demonstrated to alter neural activity after the self-regulation training was completed and to modify specific behaviours. Future exploitation of rt-fMRI-NF could be used to induce neuroplasticity in brain networks that are involved in certain neurological conditions. However, currently, the use of rt-fMRI-NF in randomized, controlled clinical trials is in its infancy.

  6. Suboxide/subnitride formation on Ta masks during magnetic material etching by reactive plasmas

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Li, Hu; Muraki, Yu; Karahashi, Kazuhiro

    2015-07-15

    Etching characteristics of tantalum (Ta) masks used in magnetoresistive random-access memory etching processes by carbon monoxide and ammonium (CO/NH{sub 3}) or methanol (CH{sub 3}OH) plasmas have been examined by mass-selected ion beam experiments with in-situ surface analyses. It has been suggested in earlier studies that etching of magnetic materials, i.e., Fe, Ni, Co, and their alloys, by such plasmas is mostly due to physical sputtering and etch selectivity of the process arises from etch resistance (i.e., low-sputtering yield) of the hard mask materials such as Ta. In this study, it is shown that, during Ta etching by energetic CO{sup +}more » or N{sup +} ions, suboxides or subnitrides are formed on the Ta surface, which reduces the apparent sputtering yield of Ta. It is also shown that the sputtering yield of Ta by energetic CO{sup +} or N{sup +} ions has a strong dependence on the angle of ion incidence, which suggests a correlation between the sputtering yield and the oxidation states of Ta in the suboxide or subnitride; the higher the oxidation state of Ta, the lower is the sputtering yield. These data account for the observed etch selectivity by CO/NH{sub 3} and CH{sub 3}OH plasmas.« less

  7. Magnetic field errors tolerances of Nuclotron booster

    NASA Astrophysics Data System (ADS)

    Butenko, Andrey; Kazinova, Olha; Kostromin, Sergey; Mikhaylov, Vladimir; Tuzikov, Alexey; Khodzhibagiyan, Hamlet

    2018-04-01

    Generation of magnetic field in units of booster synchrotron for the NICA project is one of the most important conditions for getting the required parameters and qualitative accelerator operation. Research of linear and nonlinear dynamics of ion beam 197Au31+ in the booster have carried out with MADX program. Analytical estimation of magnetic field errors tolerance and numerical computation of dynamic aperture of booster DFO-magnetic lattice are presented. Closed orbit distortion with random errors of magnetic fields and errors in layout of booster units was evaluated.

  8. Direct laser interference patterning of magnetic thin films

    NASA Astrophysics Data System (ADS)

    Aktag, Aliekber

    Recently, patterned magnetic thin films have attracted much attention for a variety of applications such as high density magnetic recording, magnetoresistive sensing, and magnetic random access memories. In the case of magnetic recording, one scheme calls for the films to be patterned into single domain "dots", where every dot represents a thermally stable bit. In this thesis, we extended a technique called direct laser interference patterning (DLIP), originally developed by Polushkin and co-workers, to pattern and locally modify the materials properties of magnetic thin films. In this technique, a high-intensity Nd:YAG pulse laser beam was split into two, three, or four beams, which are then recombined to interfere on a sample surface. The interference intensity maxima can modify the local materials properties of the film through local "annealing" or, more drastically, by ablation. We carried out some preliminary investigations of the DLIP process in several films including co-sputtered Co-C, amorphous Dy/Co:SiO2 multilayers, and Co/SiO2 multilayers in order to refine our techniques. We successfully produced regular arrays of lines, dots, or antidots formed by ablation of the thin film. The preliminary studies also showed that, in the regime of more modest pulse energies, it is possible to modify the magnetic properties of the films without noticeably changing the film topography. We then prepared perpendicular magnetic anisotropy Co/Pt multilayers with a SiO x passivation layer and applied DLIP at fairly modest intensities to pattern the film. We then studied the structural and magnetic changes that occurred in some detail. X-ray diffraction scans showed the Co/Pt:SiO x multilayer films to be nanocrystalline before and after patterning. Atomic force microscopy images showed no evidence for topographic changes of the Co/Pt:SiOx during patterning. In contrast, magnetic force microscopy showed regular periodic dot arrays, indicating that the local magnetic properties were significantly affected by the patterning process. Alternating-gradient-force magnetometry and magneto-optic measurements also showed that the magnetic properties were markedly changed by the DLIP process. Our results offer strong evidence that local heating causes the moments to change from perpendicular to in-plane, with the consequent formation of an "anisotropy lattice": dots of in-plane magnetization within a matrix of perpendicular magnetization. We also carried out some optical interference calculations to predict the light intensity distributions for two, three, and four interfering beams of light. We found that the patterns could be controlled by varying the angles of incidence, the polarizations of the beams, and the wavelength and intensity of the beams, and that a wide variety of patterns are possible. The predicted patterns were in quite good agreement with those observed experimentally.

  9. Is random access memory random?

    NASA Technical Reports Server (NTRS)

    Denning, P. J.

    1986-01-01

    Most software is contructed on the assumption that the programs and data are stored in random access memory (RAM). Physical limitations on the relative speeds of processor and memory elements lead to a variety of memory organizations that match processor addressing rate with memory service rate. These include interleaved and cached memory. A very high fraction of a processor's address requests can be satified from the cache without reference to the main memory. The cache requests information from main memory in blocks that can be transferred at the full memory speed. Programmers who organize algorithms for locality can realize the highest performance from these computers.

  10. Polarization of gamma-ray burst afterglows in the synchrotron self-Compton process from a highly relativistic jet

    NASA Astrophysics Data System (ADS)

    Lin, Hai-Nan; Li, Xin; Chang, Zhe

    2017-04-01

    Linear polarization has been observed in both the prompt phase and afterglow of some bright gamma-ray bursts (GRBs). Polarization in the prompt phase spans a wide range, and may be as high as ≳ 50%. In the afterglow phase, however, it is usually below 10%. According to the standard fireball model, GRBs are produced by synchrotron radiation and Compton scattering process in a highly relativistic jet ejected from the central engine. It is widely accepted that prompt emissions occur in the internal shock when shells with different velocities collide with each other, and the magnetic field advected by the jet from the central engine can be ordered on a large scale. On the other hand, afterglows are often assumed to occur in the external shock when the jet collides with interstellar medium, and the magnetic field produced by the shock through, for example, Weibel instability, is possibly random. In this paper, we calculate the polarization properties of the synchrotron self-Compton process from a highly relativistic jet, in which the magnetic field is randomly distributed in the shock plane. We also consider the generalized situation where a uniform magnetic component perpendicular to the shock plane is superposed on the random magnetic component. We show that it is difficult for the polarization to be larger than 10% if the seed electrons are isotropic in the jet frame. This may account for the observed upper limit of polarization in the afterglow phase of GRBs. In addition, if the random and uniform magnetic components decay with time at different speeds, then the polarization angle may change 90° during the temporal evolution. Supported by Fundamental Research Funds for the Central Universities (106112016CDJCR301206), National Natural Science Fund of China (11375203, 11603005), and Open Project Program of State Key Laboratory of Theoretical Physics, Institute of Theoretical Physics, Chinese Academy of Sciences, China (Y5KF181CJ1)

  11. Remote magnetic control of a wireless capsule endoscope in the esophagus is safe and feasible: results of a randomized, clinical trial in healthy volunteers.

    PubMed

    Keller, Jutta; Fibbe, Christiane; Volke, Frank; Gerber, Jeremy; Mosse, Alexander C; Reimann-Zawadzki, Meike; Rabinovitz, Elisha; Layer, Peter; Swain, Paul

    2010-11-01

    Remote control of esophageal capsule endoscopes could enhance diagnostic accuracy. To assess the safety and efficacy of remote magnetic manipulation of a modified capsule endoscope (magnetic maneuverable capsule [MMC]; Given Imaging Ltd, Yoqneam, Israel) in the esophagus of healthy humans. Randomized, controlled trial. Academic hospital. This study involved 10 healthy volunteers. All participants swallowed a conventional capsule (ESO2; Given Imaging) and a capsule endoscope with magnetic material, the MMC, which is activated by a thermal switch, in random order (1 week apart). An external magnetic paddle (EMP; Given Imaging) was used to manipulate the MMC within the esophageal lumen. MMC responsiveness was evaluated on a screen showing the MMC film in real time. Safety and tolerability of the procedure (questionnaire), responsiveness of the MMC to the EMP, esophageal transit time, and visualization of the Z-line. No adverse events occurred apart from mild retrosternal pressure (n = 5). The ability to rotate the MMC around its longitudinal axis and to tilt it by defined movements of the EMP was clearly demonstrated in 9 volunteers. Esophageal transit time was highly variable for both capsules (MMC, 111-1514 seconds; ESO2, 47-1474 seconds), but the MMC stayed longer in the esophagus in 8 participants (P < .01). Visualization of the Z-line was more efficient with the ESO2 (inspection of 73% ± 18% of the circumference vs 33% ± 27%, P = .01). Magnetic forces were not strong enough to hold the MMC against peristalsis when the capsule approached the gastroesophageal junction. Remote control of the MMC in the esophagus of healthy volunteers is safe and feasible, but higher magnetic forces may be needed. Copyright © 2010 American Society for Gastrointestinal Endoscopy. Published by Mosby, Inc. All rights reserved.

  12. Functional Magnetic Resonance Imaging

    ERIC Educational Resources Information Center

    Voos, Avery; Pelphrey, Kevin

    2013-01-01

    Functional magnetic resonance imaging (fMRI), with its excellent spatial resolution and ability to visualize networks of neuroanatomical structures involved in complex information processing, has become the dominant technique for the study of brain function and its development. The accessibility of in-vivo pediatric brain-imaging techniques…

  13. A Pilot Randomized Controlled Trial of the ACCESS Program: A Group Intervention to Improve Social, Adaptive Functioning, Stress Coping, and Self-Determination Outcomes in Young Adults with Autism Spectrum Disorder

    ERIC Educational Resources Information Center

    Oswald, Tasha M.; Winder-Patel, Breanna; Ruder, Steven; Xing, Guibo; Stahmer, Aubyn; Solomon, Marjorie

    2018-01-01

    The purpose of this pilot randomized controlled trial was to investigate the acceptability and efficacy of the Acquiring Career, Coping, Executive control, Social Skills (ACCESS) Program, a group intervention tailored for young adults with autism spectrum disorder (ASD) to enhance critical skills and beliefs that promote adult functioning,…

  14. Combined Use of Bivalirudin and Radial Access in Acute Coronary Syndromes Is Not Superior to the Use of Either One Separately: Meta-Analysis of Randomized Controlled Trials.

    PubMed

    Mina, George S; Gobrial, George F; Modi, Kalgi; Dominic, Paari

    2016-08-08

    The aim of this meta-analysis was to study the relation between access site and bivalirudin use on outcomes in patients with acute coronary syndrome (ACS). Bivalirudin and radial access use are 2 strategies that are increasingly used to lower major bleeding in patients with ACS undergoing invasive approaches. The interaction between these 2 strategies and the benefit of using them in combination are unclear. This analysis included randomized controlled trials that compared bivalirudin to heparin with or without glycoprotein IIb/IIIa inhibitors in patients with ACS and reported outcomes stratified by arterial access site. Meta-analyses of outcome data were performed on the basis of access site and anticoagulation regimen. Pooled odds ratios (ORs) and 95% confidence intervals (CIs) were calculated from event rates using random-effects models. Eight trials with a total of 27,491 patients were included. Bivalirudin reduced major bleeding risk in patients with femoral access (OR: 0.51; 95% CI: 0.46 to 0.6; p < 0.001) but not in patients with radial access (OR: 0.75; 95% CI: 0.45 to 1.26; p = 0.28). Moreover, radial access reduced major bleeding risk in patients treated with heparin (OR: 0.57; 95% CI: 0.43 to 0.77; p < 0.001) but not in patients treated with bivalirudin (OR: 0.96; 95% CI: 0.65 to 1.41; p = 0.83). There were no differences in major adverse cardiovascular events or all-cause mortality between bivalirudin and heparin, regardless of access site. Bivalirudin reduces bleeding risk only with femoral access, and radial access reduces bleeding risk only with heparin anticoagulation. Therefore, there is no additional benefit to the combined use of bivalirudin and radial access strategies in patients with ACS. Copyright © 2016 American College of Cardiology Foundation. Published by Elsevier Inc. All rights reserved.

  15. SYNTHETIC OBSERVATIONS OF MAGNETIC FIELDS IN PROTOSTELLAR CORES

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Lee, Joyce W. Y.; Hull, Charles L. H.; Offner, Stella S. R., E-mail: chat.hull@cfa.harvard.edu, E-mail: jwyl1g12@soton.ac.uk

    The role of magnetic fields in the early stages of star formation is not well constrained. In order to discriminate between different star formation models, we analyze 3D magnetohydrodynamic simulations of low-mass cores and explore the correlation between magnetic field orientation and outflow orientation over time. We produce synthetic observations of dust polarization at resolutions comparable to millimeter-wave dust polarization maps observed by the Combined Array for Research in Millimeter-wave Astronomy and compare these with 2D visualizations of projected magnetic field and column density. Cumulative distribution functions of the projected angle between the magnetic field and outflow show different degreesmore » of alignment in simulations with differing mass-to-flux ratios. The distribution function for the less magnetized core agrees with observations finding random alignment between outflow and field orientations, while the more magnetized core exhibits stronger alignment. We find that fractional polarization increases when the system is viewed such that the magnetic field is close to the plane of the sky, and the values of fractional polarization are consistent with observational measurements. The simulation outflow, which reflects the underlying angular momentum of the accreted gas, changes direction significantly over over the first ∼0.1 Myr of evolution. This movement could lead to the observed random alignment between outflows and the magnetic fields in protostellar cores.« less

  16. Mechanics of single cells: rheology, time dependence, and fluctuations.

    PubMed

    Massiera, Gladys; Van Citters, Kathleen M; Biancaniello, Paul L; Crocker, John C

    2007-11-15

    The results of mechanical measurements on single cultured epithelial cells using both magnetic twisting cytometry (MTC) and laser tracking microrheology (LTM) are described. Our unique approach uses laser deflection for high-performance tracking of cell-adhered magnetic beads either in response to an oscillatory magnetic torque (MTC) or due to random Brownian or ATP-dependent forces (LTM). This approach is well suited for accurately determining the rheology of single cells, the study of temporal and cell-to-cell variations in the MTC signal amplitude, and assessing the statistical character of the tracers' random motion in detail. The temporal variation of the MTC rocking amplitude is surprisingly large and manifests as a frequency-independent multiplicative factor having a 1/f spectrum in living cells, which disappears upon ATP depletion. In the epithelial cells we study, random bead position fluctuations are Gaussian to the limits of detection both in the Brownian and ATP-dependent cases, unlike earlier studies on other cell types.

  17. Effect of magnetic helicity upon rectilinear propagation of charged particles in random magnetic fields

    NASA Technical Reports Server (NTRS)

    Earl, James A.

    1992-01-01

    When charged particles spiral along a large constant magnetic field, their trajectories are scattered by any random field components that are superposed on the guiding field. If the random field configuration embodies helicity, the scattering is asymmetrical with respect to a plane perpendicular to the guiding field, for particles moving into the forward hemisphere are scattered at different rates from those moving into the backward hemisphere. This asymmetry gives rise to new terms in the transport equations that describe propagation of charged particles. Helicity has virtually no impact on qualitative features of the diffusive mode of propagation. However, characteristic velocities of the coherent modes that appear after a highly anisotropic injection exhibit an asymmetry related to helicity. Explicit formulas, which embody the effects of helicity, are given for the anisotropies, the coefficient diffusion, and the coherent velocities. Predictions derived from these expressions are in good agreement with Monte Carlo simulations of particle transport, but the simulations reveal certain phenomena whose explanation calls for further analytical work.

  18. A multi-level intervention in subsidized housing sites to increase fruit and vegetable access and intake: Rationale, design and methods of the 'Live Well, Viva Bien' cluster randomized trial.

    PubMed

    Gans, Kim M; Gorham, Gemma; Risica, Patricia M; Dulin-Keita, Akilah; Dionne, Laura; Gao, Tina; Peters, Sarah; Principato, Ludovica

    2016-06-28

    Adequate fruit and vegetable (F&V) intake is important for disease prevention. Yet, most Americans, especially low-income and racial/ethnic minorities, do not eat adequate amounts. These disparities are partly attributable to food environments in low-income neighborhoods where residents often have limited access to affordable, healthful food and easy access to inexpensive, unhealthful foods. Increasing access to affordable healthful food in underserved neighborhoods through mobile markets is a promising, year-round strategy for improving dietary behaviors and reducing F&V intake disparities. However, to date, there have been no randomized controlled trials studying their effectiveness. The objective of the 'Live Well, Viva Bien' (LWVB) cluster randomized controlled trial is to evaluate the efficacy of a multicomponent mobile market intervention at increasing F&V intake among residents of subsidized housing complexes. One housing complex served as a pilot site for the intervention group and the remaining 14 demographically-matched sites were randomized into either the intervention or control group. The intervention group received bimonthly, discount, mobile, fresh F&V markets in conjunction with a nutrition education intervention (two F&V campaigns, newsletters, DVDs and cooking demonstrations) for 12 months. The control group received physical activity and stress reduction interventions. Outcome measures include F&V intake (measured by two validated F&V screeners at baseline, six-month and twelve-months) along with potential psychosocial mediating variables. Extensive quantitative and qualitative process evaluation was also conducted throughout the study. Modifying neighborhood food environments in ways that increase access to affordable, healthful food is a promising strategy for improving dietary behaviors among low-income, racial and ethnic minority groups at increased risk for obesity and other food-related chronic diseases. Discount, mobile F&V markets address all the major barriers to eating more F&V (high cost, poor quality, limited access and limited time to shop and cook) and provide a year-round solution to limited access to healthful food in low-income neighborhoods. LWVB is the first randomized controlled trial evaluating the effectiveness of mobile markets at increasing F&V intake. If proven efficacious at increasing F&V consumption, LWVB could be disseminated widely to neighborhoods that have low access to fresh F&V. Clinicatrials.gov registration number: NCT02669472 First Received: January 19, 2016.

  19. The IRM at 25: A Quarter Century of Community-Based Research and Education at the Institute for Rock Magnetism

    NASA Astrophysics Data System (ADS)

    Moskowitz, B. M.

    2015-12-01

    A 1986 meeting on the future of rock magnetism proposed an idea for a center where researchers in rock magnetism, other earth science disciplines, and allied fields in the physical sciences could share ideas and have access to advanced instrumentation in magnetism. The idea became reality in 1990, when the Institute for Rock Magnetism (IRM) was established as a shared resource for the GP and broader research communities, providing instruments to study the magnetism of rocks, sediment, biological materials and synthetic analogs. This is accomplished with a suite of instruments that measures magnetization from 2-1000 K, in DC fields up to 5 T and AC fields up to 10 kHz. These are complemented by Mössbauer spectrometers (4.2-300K, 0-6.5T), a high-temperature magnetic force microscope (Tmax~ 673 K), and a low-temperature probe (20-300 K) for vector remanence measurements. A unique aspect of the IRM was that it allowed for routine measurements below 300 K and provided new ways of "seeing" magnetism. This has enabled researchers to study magnetic behavior through magnetic ordering temperatures, crystal phase transitions, and blocking temperatures, providing new insights into mineral magnetism as well as developing new methods to interpret the magnetism of natural materials. The main access to the IRM is the Visiting Fellowship (VF) program, where 379 have been awarded representing 157 institutions from the US and 30 countries. Nearly 50% of VFs have gone to students. The total output of visiting and in-house researches have produced about 800 publications to date. The IRM also provides education and outreach activities including: (1) The IRM Quarterly with over 600 subscribers; (2) The Biennial Santa Fe meetings on the current state and future trends in magnetic research; and (3) The Biennial Summer Schools for Rock Magnetism offering graduate students in the geosciences with instruction in rock magnetism theory and hands-on lab training.

  20. Interplanetary space science data base and access/display tool on the NSSDC heliospheric CD-ROM

    NASA Technical Reports Server (NTRS)

    Papitashvili, N. E.; King, J. H.

    1995-01-01

    The National Space Science Data Center (NSSDC) has accumulated a rich archive of heliospheric, magnetospheric, and ionospheric data, as well as data from most other NASA-involved science disciplines. To facilitate access to and use of these data, NSSDC has begun to put selected data onto CD-ROM's. This paper describes one such CD-ROM, and the access and display software developed at NSSDC to support its use. The data on the CD-ROM consist primarily of hourly solar wind magnetic field and plasma data from many near-Earth spacecraft (OMNI) and deep space spacecraft (Voyagers, Pioneers, Helios, Pioneer Venus Orbiter). In addition, 5-minute resolution IMP-8 and ISEE-3 magnetic field and plasma data are also included. Data are stored in both ASCII and CDF formats.

  1. Understanding the patient perspective on research access to national health records databases for conduct of randomized registry trials.

    PubMed

    Avram, Robert; Marquis-Gravel, Guillaume; Simard, François; Pacheco, Christine; Couture, Étienne; Tremblay-Gravel, Maxime; Desplantie, Olivier; Malhamé, Isabelle; Bibas, Lior; Mansour, Samer; Parent, Marie-Claude; Farand, Paul; Harvey, Luc; Lessard, Marie-Gabrielle; Ly, Hung; Liu, Geoffrey; Hay, Annette E; Marc Jolicoeur, E

    2018-07-01

    Use of health administrative databases is proposed for screening and monitoring of participants in randomized registry trials. However, access to these databases raises privacy concerns. We assessed patient's preferences regarding use of personal information to link their research records with national health databases, as part of a hypothetical randomized registry trial. Cardiology patients were invited to complete an anonymous self-reported survey that ascertained preferences related to the concept of accessing government health databases for research, the type of personal identifiers to be shared and the type of follow-up preferred as participants in a hypothetical trial. A total of 590 responders completed the survey (90% response rate), the majority of which were Caucasians (90.4%), male (70.0%) with a median age of 65years (interquartile range, 8). The majority responders (80.3%) would grant researchers access to health administrative databases for screening and follow-up. To this end, responders endorsed the recording of their personal identifiers by researchers for future record linkage, including their name (90%), and health insurance number (83.9%), but fewer responders agreed with the recording of their social security number (61.4%, p<0.05 with date of birth as reference). Prior participation in a trial predicted agreement for granting researchers access to the administrative databases (OR: 1.69, 95% confidence interval: 1.03-2.90; p=0.04). The majority of Cardiology patients surveyed were supportive of use of their personal identifiers to access administrative health databases and conduct long-term monitoring in the context of a randomized registry trial. Copyright © 2018 Elsevier Ireland Ltd. All rights reserved.

  2. An exploratory study of Taiwanese consumers' experiences of using health-related websites.

    PubMed

    Hsu, Li-Ling

    2005-06-01

    It is manifest that the rapid growth of Internet use and improvement of information technology have changed our lifestyles. In recent years, Internet use in Taiwan has increased dramatically, from 3 million users in 1998 to approximately 8.6 million by the end of 2002. The statistics imply that not only health care professionals but also laypersons rely on the Internet for health information. The purpose of this study was to explore Taiwan consumers' preferences and information needs, and the problems they encountered when getting information from medical websites. Using simple random sampling and systematic random sampling, a survey was conducted in Taipei from August 26, 2002 to October 30, 2002. Using simple random sampling and systematic random sampling, 28 boroughs (Li) were selected; the total sample number was 1043. Over one-quarter (26.8 %) of the respondents reported having never accessed the Internet, while 763 (73.2%) reported having accessed the Internet. Of the Internet users, only 396 (51.9%) had accessed health-related websites, and 367 (48.1%) reported having never accessed health-related websites. The most popular topics were disease information (46.5%), followed by diet consultation (34.8%), medical news (28.5%), and cosmetology (28.5%). The results of the survey show that a large percentage of people in Taiwan have never made good use of health information available on the websites. The reasons for not using the websites included a lack of time or Internet access skills, no motivation, dissatisfaction with the information, unreliable information be provided, and inability to locate the information needed. The author recommends to enhance health information access skills, understand the needs and preferences of consumers, promote the quality of medical websites, and improve the functions of medical websites.

  3. Precessional Switching of Thin Nanomagnets with Uniaxial Anisotropy

    NASA Astrophysics Data System (ADS)

    Devolder, Thibaut; Schumacher, Hans Werner; Chappert, Claude

    This review describes the evolution of the magnetization of uniaxial thin magnets when subjected to fast-rising magnetic-field pulses. We report detailed "all-electrical" experimental investigations of precessional switching on soft uniaxial micrometer-sized thin magnets, and we discuss them using a comprehensive, mostly analytical framework. General criteria are derived for the analytical assessment of the switching ability of any arbitrary set of experimental parameters. For this, we start from the Landau-Lifshitz equation and first consider the precessional switching in a much idealized macrospin, easy-plane loss-free system. We then test the main outputs of this model with time-resolved experiments on advanced Magnetic Random Access Memories (MRAM) cells. Using applied fields above the anisotropy field H k , we prove the quasiperiodic nature of the magnetization trajectory and we demonstrate experimental conditions ensuring a sub-200 ps ballistic magnetization reversal. We then upgrade our model accuracy by taking into account the uniaxial anisotropy and the behavior in hard-axis fields of the order of H k . We derive a simple though reliable estimate of the switching speed; its limiting factors highlight the experimental poor switching reproducibility when close to the minimal hard-axis reversal field H k /2. The latter field does not correspond to the minimal energy cost of the reversal, whose prospective evolution in the future generations of MRAM is predicted. Small departures from the macrospin state are discussed. The effect of damping is modeled using perturbation theory. Finite damping alters the precessional motion periodicity and puts some constraints on the field rise time. A special focus is dedicated to the relaxation-dominated precessional switching: the minimal hard-axis field triggering the switching is shown to be above H k /2 by an extra field cost linked to the damping constant times the square root of M S H k . Finally, the selective addressing and the direct-write of a magnetic cell with combined easy-axis and hard-axis fields are studied. We introduce the concept of bounce and revisit the dynamical astroid to derive the related characteristic reversal durations and their margins. We propose a field timing that is immune to the delay jitter between the combined addressing fields. We finish by investigating briefly the challenges and the promises of the "precessional" strategy for future MRAM generations.

  4. Zero-field random-field effect in diluted triangular lattice antiferromagnet CuFe1-xAlxO2

    NASA Astrophysics Data System (ADS)

    Nakajima, T.; Mitsuda, S.; Kitagawa, K.; Terada, N.; Komiya, T.; Noda, Y.

    2007-04-01

    We performed neutron scattering experiments on a diluted triangular lattice antiferromagnet (TLA), CuFe1-xAlxO2 with x = 0.10. The detailed analysis of the scattering profiles revealed that the scattering function of magnetic reflection is described as the sum of a Lorentzian term and a Lorentzian-squared term with anisotropic width. The Lorentzian-squared term dominating at low temperature is indicative of the domain state in the prototypical random-field Ising model. Taking account of the sinusoidally amplitude-modulated magnetic structure with incommensurate wavenumber in CuFe1-xAlxO2 with x = 0.10, we conclude that the effective random field arises even at zero field, owing to the combination of site-random magnetic vacancies and the sinusoidal structure that is regarded as a partially disordered (PD) structure in a wide sense, as reported in the typical three-sublattice PD phase of a diluted Ising TLA, CsCo0.83Mg0.17Br3 (van Duijn et al 2004 Phys. Rev. Lett. 92 077202). While the previous study revealed the existence of a domain state in CsCo0.83Mg0.17Br3 by detecting magnetic reflections specific to the spin configuration near the domain walls, our present study revealed the existence of a domain state in CuFe1-xAlxO2 (x = 0.10) by determination of the functional form of the scattering function.

  5. A New In Vitro Co-Culture Model Using Magnetic Force-Based Nanotechnology.

    PubMed

    Takanari, Hiroki; Miwa, Keiko; Fu, XianMing; Nakai, Junichi; Ito, Akira; Ino, Kousuke; Honda, Hiroyuki; Tonomura, Wataru; Konishi, Satoshi; Opthof, Tobias; van der Heyden, Marcel Ag; Kodama, Itsuo; Lee, Jong-Kook

    2016-10-01

    Skeletal myoblast (SkMB) transplantation has been conducted as a therapeutic strategy for severe heart failure. However, arrhythmogenicity following transplantation remains unsolved. We developed an in vitro model of myoblast transplantation with "patterned" or "randomly-mixed" co-culture of SkMBs and cardiomyocytes enabling subsequent electrophysiological, and arrhythmogenic evaluation. SkMBs were magnetically labeled with magnetite nanoparticles and co-cultured with neonatal rat ventricular myocytes (NRVMs) on multi-electrode arrays. SkMBs were patterned by a magnet beneath the arrays. Excitation synchronicity was evaluated by Ca(2+) imaging using a gene-encoded Ca(2+) indicator, G-CaMP2. In the monoculture of NRVMs (control), conduction was well-organized. In the randomly-mixed co-culture of NRVMs and SkMBs (random group), there was inhomogeneous conduction from multiple origins. In the "patterned" co-culture where an en bloc SKMB-layer was inserted into the NRVM-layer, excitation homogenously propagated although conduction was distorted by the SkMB-area. The 4-mm distance conduction time (CT) in the random group was significantly longer (197 ± 126 ms) than in control (17 ± 3 ms). In the patterned group, CT through NRVM-area did not change (25 ± 3 ms), although CT through the SkMB-area was significantly longer (132 ± 77 ms). The intervals between spontaneous excitation varied beat-to-beat in the random group, while regular beating was recorded in the control and patterned groups. Synchronized Ca(2+) transients of NRVMs were observed in the patterned group, whereas those in the random group were asynchronous. Patterned alignment of SkMBs is feasible with magnetic nanoparticles. Using the novel in vitro model mimicking cell transplantation, it may become possible to predict arrhythmogenicity due to heterogenous cell transplantation. J. Cell. Physiol. 231: 2249-2256, 2016. © 2016 Wiley Periodicals, Inc. © 2016 Wiley Periodicals, Inc.

  6. Portable mass spectrometer with one or more mechanically adjustable electrostatic sectors and a mechanically adjustable magnetic sector all mounted in a vacuum chamber

    DOEpatents

    Andresen, B.D.; Eckels, J.D.; Kimmons, J.F.; Martin, W.H.; Myers, D.W.; Keville, R.F.

    1992-10-06

    A portable mass spectrometer is described having one or more electrostatic focusing sectors and a magnetic focusing sector, all of which are positioned inside a vacuum chamber, and all of which may be adjusted via adjustment means accessible from outside the vacuum chamber. Mounting of the magnetic sector entirely within the vacuum chamber permits smaller magnets to be used, thus permitting reductions in both weight and bulk. 13 figs.

  7. A symmetric, triply interlaced 3-D anionic MOF that exhibits both magnetic order and SMM behaviour.

    PubMed

    Campo, J; Falvello, L R; Forcén-Vázquez, E; Sáenz de Pipaón, C; Palacio, F; Tomás, M

    2016-11-14

    A newly prepared 3-D polymer of cobalt citrate cubanes bridged by high-spin Co(ii) centres displays both single-molecule magnet (SMM) behaviour and magnetic ordering. Triple interpenetration of the 3-D diamondoid polymers yields a crystalline solid with channels that host cations and free water molecules, with the SMM behaviour of the Co 4 O 4 cores preserved. The octahedrally coordinated Co(ii) bridges are implicated in the onset of magnetic order at an experimentally accessible temperature.

  8. The effects of the one-step replica symmetry breaking on the Sherrington-Kirkpatrick spin glass model in the presence of random field with a joint Gaussian probability density function for the exchange interactions and random fields

    NASA Astrophysics Data System (ADS)

    Hadjiagapiou, Ioannis A.; Velonakis, Ioannis N.

    2018-07-01

    The Sherrington-Kirkpatrick Ising spin glass model, in the presence of a random magnetic field, is investigated within the framework of the one-step replica symmetry breaking. The two random variables (exchange integral interaction Jij and random magnetic field hi) are drawn from a joint Gaussian probability density function characterized by a correlation coefficient ρ, assuming positive and negative values. The thermodynamic properties, the three different phase diagrams and system's parameters are computed with respect to the natural parameters of the joint Gaussian probability density function at non-zero and zero temperatures. The low temperature negative entropy controversy, a result of the replica symmetry approach, has been partly remedied in the current study, leading to a less negative result. In addition, the present system possesses two successive spin glass phase transitions with characteristic temperatures.

  9. Can Nonexperimental Estimates Replicate Estimates Based on Random Assignment in Evaluations of School Choice? A Within-Study Comparison

    ERIC Educational Resources Information Center

    Bifulco, Robert

    2012-01-01

    The ability of nonexperimental estimators to match impact estimates derived from random assignment is examined using data from the evaluation of two interdistrict magnet schools. As in previous within-study comparisons, nonexperimental estimates differ from estimates based on random assignment when nonexperimental estimators are implemented…

  10. Leading Change: A Case Study of the First Independent Critical-Access Hospital to Achieve Magnet® Designation.

    PubMed

    Nelson-Brantley, Heather V; Ford, Debra J; Miller, Karen L; Stegenga, Kristin A; Lee, Robert H; Bott, Marjorie J

    2018-03-01

    The aim of this study was to understand how nurses in a 25-bed critical-access hospital (CAH) led change to become the 1st to achieve Magnet®. Approximately 21% of the US population lives in rural areas served by CAHs. Rural nurse executives are particularly challenged with limited resources. Staff nurses, nurse managers, interprofessional care providers, the chief nursing officer, and board of directors (n = 27) were interviewed. Observations of hospital units and administrative meetings were done, and hospital reports were analyzed. Nine themes emerged to support a conceptual model of leading change. The CAH spent 3 years of its 6-year journey establishing organizational readiness. Nurses overcame complex challenges by balancing operational support and fostering relationships. The Magnet journey led to significantly improved nurse and patient outcomes. A new organizational culture centered on shared governance, evidence-based practice, and higher education emerged. The journey to Magnet leads to improved nurse, patient, and organization outcomes.

  11. Free choice access to multipoint wellness education and related services positively impacts employee wellness: a randomized and controlled trial.

    PubMed

    Sforzo, Gary A; Kaye, Miranda P; Calleri, David; Ngai, Nancy

    2012-04-01

    Examine effects of voluntary participation in employer-sponsored, multipoint wellness education programming on employee wellness. A randomized and controlled design was used to organize 96 participants into an education + access group; an access-only group, and control group. Outcome measures were made at start and end of a 12-week intervention period. Education + access improved wellness knowledge, which, in turn, enhanced life satisfaction, employee morale, and energy, and nearly improved stress level. Those who received facility access without educational programming did not reap health benefits. Employees voluntarily used the fitness facility and healthy meal cards only 1.3 and 1.5 times per week, respectively. Participants made limited and likely inadequate use of wellness opportunities. As a result, physical health benefits (eg, blood pressure, fitness parameters) were not seen in the present study. However, multipoint wellness education resulted in psychosocial health benefits in 12 weeks.

  12. Discussing Firearm Ownership and Access as Part of Suicide Risk Assessment and Prevention: "Means Safety" versus "Means Restriction".

    PubMed

    Stanley, Ian H; Hom, Melanie A; Rogers, Megan L; Anestis, Michael D; Joiner, Thomas E

    2017-01-01

    The goal of this study was to describe the relative utility of the terms "means safety" versus "means restriction" in counseling individuals to limit their access to firearms in the context of a mock suicide risk assessment. Overall, 370 participants were randomized to read a vignette depicting a clinical scenario in which managing firearm ownership and access was discussed either using the term "means safety" or "means restriction." Participants rated the term "means safety" as significantly more acceptable and preferable than "means restriction." Participants randomized to the "means safety" condition reported greater intentions to adhere to clinicians' recommendations to limit access to a firearm for safety purposes (F[1,367] = 7.393, p = .007, [Formula: see text]). The term "means safety" may be more advantageous than "means restriction" when discussing firearm ownership and access in clinical settings and public health-oriented suicide prevention efforts.

  13. Dynamics of arbitrary shaped propellers driven by a rotating magnetic field

    NASA Astrophysics Data System (ADS)

    Morozov, Konstantin I.; Mirzae, Yoni; Kenneth, Oded; Leshansky, Alexander M.

    2017-04-01

    Motion in fluids at the micro(nano)metric scale is dominated by viscosity. One efficient propulsion method relies on a weak uniform rotating magnetic field that drives a chiral object. From bacterial flagella to artificial magnetic micro- or nanohelices, rotation of a corkscrew is considered as a universally efficient propulsion gait in viscous environments. However, recent experimental studies have demonstrated that geometrically achiral microscale objects or random-shaped magnetic aggregates can propel similarly to helical micromotors. Although approximate theories concerning dynamics of helical magnetic propellers are available, propulsion of achiral particles or objects with complex shapes is not understood. Here we present a general theory of rotation and propulsion of magnetized object of arbitrary shape driven by a rotating magnetic field. Intrinsic symmetries of the viscous mobility tensors yield compact classification of stable rotational states depending on the orientation of the magnetic moment with respect to principal rotation axes of the object. Propulsion velocity can be written in terms of geometry-dependent chirality matrix Ch , where both the diagonal elements (owing to orientation-dependent handedness) and off-diagonal entries (that do not necessitate handedness) contribute in a similar way. In general, the theory anticipates multiplicity of stable rotational states corresponding to two (complimentary to π ) angles the magnetization forms with the field rotation axis. Thus, two identical magnetic objects may propel with different speeds or even in opposite directions. However, for a class of simple achiral objects, there is a particular magnetization whereas the pair of symmetric rotational states gives rise to a unique chiral-like propulsion gait, closely resembling that of an ideal helical propeller. In other words, a geometrically achiral object can acquire apparent chirality due to its interaction with the external magnetic field. The developed theory is further applied to study the dynamics of achiral, chiral, and random-shaped magnetic propellers, rationalizing previously unexplained experimental observations. The genetic search algorithm based on the proposed theory reveals that an arc-shaped segment is the optimal (fastest) achiral propeller, while the optimal skew-symmetric shape deviates considerably from a helix. Remarkably, an optimized arc-shaped propeller warrants propulsion speeds comparable to those of the optimally magnetized helix. Although random shaped magnetic aggregates appear to be poor swimmers at low actuation frequency, at higher frequency, whereas the helical propeller ceases to rotate in-sync with the field, the propulsion speed of the aggregates could be comparable, or even higher, than that of a helix.

  14. Role of motive forces for the spin torque transfer for nano-structures

    NASA Astrophysics Data System (ADS)

    Barnes, Stewart

    2009-03-01

    Despite an announced imminent commercial realization of spin transfer random access memory (SPRAM) the current theory evolved from that of Slonczewski [1,2] does not conserve energy. Barnes and Maekawa [3] have shown, in order correct this defect, forces which originate from the spin rather than the charge of an electron must be accounted for, this leading to the concept of spin-motive-forces (smf) which must appear in Faraday's law and which significantly modifies the theory for spin-valves and domain wall devices [4]. A multi-channel theory in which these smf's redirect the spin currents will be described. In nano-structures it is now well known that the Kondo effect is reflected by conductance peaks. In essence, the spin degrees of freedom are used to enhance conduction. In a system with nano-magnets and a Coulomb blockade [5] the similar spin channels can be the only means of effective conduction. This results in a smf which lasts for minutes and an enormous magneto-resistance [5]. This implies the possibility of ``single electron memory'' in which the magnetic state is switched by a single electron. [4pt] [1] J. C. Slonczewski, Current-Driven Excitation of Magnetic Multilayers J. Magn. Magn. Mater. 159, L1 (1996). [0pt] [2] Y. Tserkovnyak, A. Brataas, G. E. W. Bauer, and B. I. Halperin, Nonlocal magnetization dynamics in ferromagnetic heterostructures, Rev. Mod. Phys. 77, 1375 (2005). [0pt] [3] S. E. Barnes and S. Maekawa, Generalization of Faraday's Law to Include Nonconservative Spin Forces Phys. Rev. Lett. 98, 246601 (2007); S. E. Barnes and S. Maekawa, Currents induced by domain wall motion in thin ferromagnetic wires. arXiv:cond-mat/ 0410021v1 (2004). [0pt] [4] S. E., Barnes, Spin motive forces, measurement, and spin-valves. J. Magn. Magn. Mat. 310, 2035-2037 (2007); S. E. Barnes, J. Ieda. J and S. Maekawa, Magnetic memory and current amplification devices using moving domain walls. Appl. Phys. Lett. 89, 122507 (2006). [0pt] [5] Pham-Nam Hai, Byung-Ho Yu, Shinobu Ohya, Masaaki Tanaka, Stewart E. Barnes and Sadamichi Maekawa, Electromotive force and huge magnetoresistance in magnetic tunnel junctions. Submitted Nature, August, (2008).

  15. Highly controlled orientation of CaBi4Ti4O15 using a strong magnetic field

    NASA Astrophysics Data System (ADS)

    Suzuki, Tohru S.; Kimura, Masahiko; Shiratsuyu, Kosuke; Ando, Akira; Sakka, Yoshio; Sakabe, Yukio

    2006-09-01

    The texture of feeble magnetic ceramics can be controlled by a strong magnetic field. When the magnetic susceptibility of the c axis is smaller than that of the other axes, the c axis aligns perpendicular to the magnetic field; however, the direction is randomly oriented on the plane perpendicular to the magnetic field. The authors demonstrate in this letter that a highly controlled texture in bismuth titanate, which has a c-axis susceptibility smaller than the other axes, can be achieved using a two-step magnetic field procedure. This highly controlled orientation is effective for improving the electromechanical coupling coefficient.

  16. Implementation of nitrogen-doped titanium-tungsten tunable heater in phase change random access memory and its effects on device performance

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Tan, Chun Chia; Zhao, Rong, E-mail: zhao-rong@sutd.edu.sg; Chong, Tow Chong

    2014-10-13

    Nitrogen-doped titanium-tungsten (N-TiW) was proposed as a tunable heater in Phase Change Random Access Memory (PCRAM). By tuning N-TiW's material properties through doping, the heater can be tailored to optimize the access speed and programming current of PCRAM. Experiments reveal that N-TiW's resistivity increases and thermal conductivity decreases with increasing nitrogen-doping ratio, and N-TiW devices displayed (∼33% to ∼55%) reduced programming currents. However, there is a tradeoff between the current and speed for heater-based PCRAM. Analysis of devices with different N-TiW heaters shows that N-TiW doping levels could be optimized to enable low RESET currents and fast access speeds.

  17. Random Fields and Collective Effects in Molecular Magnets

    DTIC Science & Technology

    2018-01-29

    longitudinal fields the final state consists of only partially reversed spins. Further, we measured the front speed as a function of applied magnetic...field. The theory of magnetic deflagration, together with a modification that takes into account the partial spin reversal, fits the transverse field...Conference Paper or Presentation Conference Name: APS March Meeting 2016 Conference Location: Baltimore, Paper Title: Time-resolved Measurements

  18. Properties of highly frustrated magnetic molecules studied by the finite-temperature Lanczos method

    NASA Astrophysics Data System (ADS)

    Schnack, J.; Wendland, O.

    2010-12-01

    The very interesting magnetic properties of frustrated magnetic molecules are often hardly accessible due to the prohibitive size of the related Hilbert spaces. The finite-temperature Lanczos method is able to treat spin systems for Hilbert space sizes up to 109. Here we first demonstrate for exactly solvable systems that the method is indeed accurate. Then we discuss the thermal properties of one of the biggest magnetic molecules synthesized to date, the icosidodecahedron with antiferromagnetically coupled spins of s = 1/2. We show how genuine quantum features such as the magnetization plateau behave as a function of temperature.

  19. Co nanocrystals engineering

    NASA Astrophysics Data System (ADS)

    Fontaiña-Troitiño, N.; Ciuculescu-Pradines, D.; Correa-Duarte, M. A.; Salgueiriño, V.; Amiens, C.

    2017-06-01

    Organometallic chemistry plays an increasing role in the synthesis of nanoparticles, as it provides a reliable access to metal nanoparticles with efficient control over their morphology, organization and surface chemistry. In case of magnetic nanoparticles, the synthetic tools provided by organometallic chemistry allow access to nanomaterials of high magnetization, meaning that no dead surface magnetic layer is observed. These objects are thus good candidates to be used as building blocks in composite materials of high added value. This paper reports on the organometallic synthesis of composites made of cobalt nanoparticles and carbon nanotubes. TEM investigations show that attachment of cobalt spheres and rods along the carbon nanotubes is achieved, the rods and tube long axis being aligned parallel to one another. Invited talk at 8th Int. Workshop on Advanced Materials Science and Nanotechnology (Ha Long City, Vietnam, 8-12 November 2016).

  20. Integrated Vertical Bloch Line (VBL) memory

    NASA Technical Reports Server (NTRS)

    Katti, R. R.; Wu, J. C.; Stadler, H. L.

    1991-01-01

    Vertical Bloch Line (VBL) Memory is a recently conceived, integrated, solid state, block access, VLSI memory which offers the potential of 1 Gbit/sq cm areal storage density, data rates of hundreds of megabits/sec, and submillisecond average access time simultaneously at relatively low mass, volume, and power values when compared to alternative technologies. VBLs are micromagnetic structures within magnetic domain walls which can be manipulated using magnetic fields from integrated conductors. The presence or absence of BVL pairs are used to store binary information. At present, efforts are being directed at developing a single chip memory using 25 Mbit/sq cm technology in magnetic garnet material which integrates, at a single operating point, the writing, storage, reading, and amplification functions needed in a memory. The current design architecture, functional elements, and supercomputer simulation results are described which are used to assist the design process.

  1. Quantum Coherence and Random Fields at Mesoscopic Scales

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Rosenbaum, Thomas F.

    2016-03-01

    We seek to explore and exploit model, disordered and geometrically frustrated magnets where coherent spin clusters stably detach themselves from their surroundings, leading to extreme sensitivity to finite frequency excitations and the ability to encode information. Global changes in either the spin concentration or the quantum tunneling probability via the application of an external magnetic field can tune the relative weights of quantum entanglement and random field effects on the mesoscopic scale. These same parameters can be harnessed to manipulate domain wall dynamics in the ferromagnetic state, with technological possibilities for magnetic information storage. Finally, extensions from quantum ferromagnets tomore » antiferromagnets promise new insights into the physics of quantum fluctuations and effective dimensional reduction. A combination of ac susceptometry, dc magnetometry, noise measurements, hole burning, non-linear Fano experiments, and neutron diffraction as functions of temperature, magnetic field, frequency, excitation amplitude, dipole concentration, and disorder address issues of stability, overlap, coherence, and control. We have been especially interested in probing the evolution of the local order in the progression from spin liquid to spin glass to long-range-ordered magnet.« less

  2. Collaborative Indoor Access Point Localization Using Autonomous Mobile Robot Swarm.

    PubMed

    Awad, Fahed; Naserllah, Muhammad; Omar, Ammar; Abu-Hantash, Alaa; Al-Taj, Abrar

    2018-01-31

    Localization of access points has become an important research problem due to the wide range of applications it addresses such as dismantling critical security threats caused by rogue access points or optimizing wireless coverage of access points within a service area. Existing proposed solutions have mostly relied on theoretical hypotheses or computer simulation to demonstrate the efficiency of their methods. The techniques that rely on estimating the distance using samples of the received signal strength usually assume prior knowledge of the signal propagation characteristics of the indoor environment in hand and tend to take a relatively large number of uniformly distributed random samples. This paper presents an efficient and practical collaborative approach to detect the location of an access point in an indoor environment without any prior knowledge of the environment. The proposed approach comprises a swarm of wirelessly connected mobile robots that collaboratively and autonomously collect a relatively small number of non-uniformly distributed random samples of the access point's received signal strength. These samples are used to efficiently and accurately estimate the location of the access point. The experimental testing verified that the proposed approach can identify the location of the access point in an accurate and efficient manner.

  3. Collaborative Indoor Access Point Localization Using Autonomous Mobile Robot Swarm

    PubMed Central

    Awad, Fahed; Naserllah, Muhammad; Omar, Ammar; Abu-Hantash, Alaa; Al-Taj, Abrar

    2018-01-01

    Localization of access points has become an important research problem due to the wide range of applications it addresses such as dismantling critical security threats caused by rogue access points or optimizing wireless coverage of access points within a service area. Existing proposed solutions have mostly relied on theoretical hypotheses or computer simulation to demonstrate the efficiency of their methods. The techniques that rely on estimating the distance using samples of the received signal strength usually assume prior knowledge of the signal propagation characteristics of the indoor environment in hand and tend to take a relatively large number of uniformly distributed random samples. This paper presents an efficient and practical collaborative approach to detect the location of an access point in an indoor environment without any prior knowledge of the environment. The proposed approach comprises a swarm of wirelessly connected mobile robots that collaboratively and autonomously collect a relatively small number of non-uniformly distributed random samples of the access point’s received signal strength. These samples are used to efficiently and accurately estimate the location of the access point. The experimental testing verified that the proposed approach can identify the location of the access point in an accurate and efficient manner. PMID:29385042

  4. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Pisokas, Theophilos; Vlahos, Loukas; Isliker, Heinz

    The aim of this study is to analyze the interaction of charged particles (ions and electrons) with randomly formed particle scatterers (e.g., large-scale local “magnetic fluctuations” or “coherent magnetic irregularities”) using the setup proposed initially by Fermi. These scatterers are formed by the explosive magnetic energy release and propagate with the Alfvén speed along the irregular magnetic fields. They are large-scale local fluctuations ( δB / B ≈ 1) randomly distributed inside the unstable magnetic topology and will here be called Alfvénic Scatterers (AS). We constructed a 3D grid on which a small fraction of randomly chosen grid points aremore » acting as AS. In particular, we study how a large number of test particles evolves inside a collection of AS, analyzing the evolution of their energy distribution and their escape-time distribution. We use a well-established method to estimate the transport coefficients directly from the trajectories of the particles. Using the estimated transport coefficients and solving the Fokker–Planck equation numerically, we can recover the energy distribution of the particles. We have shown that the stochastic Fermi energization of mildly relativistic and relativistic plasma can heat and accelerate the tail of the ambient particle distribution as predicted by Parker and Tidman and Ramaty. The temperature of the hot plasma and the tail of the energetic particles depend on the mean free path ( λ {sub sc}) of the particles between the scatterers inside the energization volume.« less

  5. A Retrospective Look at Website Accessibility over Time

    ERIC Educational Resources Information Center

    Hackett, Stephanie; Parmanto, Bambang; Zeng, Xiaoming

    2005-01-01

    Websites were retrospectively analysed to study the effects that technological advances in web design have had on accessibility for persons with disabilities. A random sample of general websites and a convenience sample of US government websites were studied and compared for the years 1997-2002. Web accessibility barrier (WAB) and complexity…

  6. Repetitive transcranial magnetic stimulation as an alternative therapy for dysphagia after stroke: a systematic review and meta-analysis.

    PubMed

    Liao, Xiang; Xing, Guoqiang; Guo, Zhiwei; Jin, Yu; Tang, Qing; He, Bin; McClure, Morgan A; Liu, Hua; Chen, Huaping; Mu, Qiwen

    2017-03-01

    A meta-analysis and systematic review was conducted to investigate the potential effects of repetitive transcranial magnetic stimulation on dysphagia in patients with stroke, including different parameters of frequency and stimulation site. PubMed, Embase, MEDLINE databases and the Cochrane Library, were searched for randomized controlled studies of repetitive transcranial magnetic stimulation treatment of dysphagia published before March 2016. Six clinical randomized controlled studies of a total of 163 stroke patients were included in this meta-analysis. A significant effect size of 1.24 was found for dysphagic outcome (mean effect size, 1.24; 95% confidence interval (CI), 0.67-1.81). A subgroup analysis based on frequency showed that the clinical scores were significantly improved in dysphagic patients with low frequency repetitive transcranial magnetic stimulation treatment ( P < 0.05) as well as high frequency repetitive transcranial magnetic stimulation treatment ( P < 0.05). A stimulation site stratified subgroup analysis implied significant changes in stroke patients with dysphagia for the unaffected hemisphere ( P < 0.05) and the bilateral hemisphere stimulation ( P < 0.05), but not for the affected hemisphere ( P > 0.05). The analysis of the follow-up data shows that patients in the repetitive transcranial magnetic stimulation groups still maintained the therapeutic benefit of repetitive transcranial magnetic stimulation four weeks after the last session of repetitive transcranial magnetic stimulation therapy ( P < 0.05). This meta-analysis indicates that repetitive transcranial magnetic stimulation has a positive effect on dysphagia after stroke. Compared with low-frequency repetitive transcranial magnetic stimulation, high-frequency repetitive transcranial magnetic stimulation may be more beneficial to the patients. This meta-analysis also supports that repetitive transcranial magnetic stimulation on an unaffected - or bilateral - hemisphere has a significant therapeutic effect on dysphagia.

  7. Electrical Evaluation of RCA MWS5001D Random Access Memory, Volume 5, Appendix D

    NASA Technical Reports Server (NTRS)

    Klute, A.

    1979-01-01

    The electrical characterization and qualification test results are presented for the RCA MWS 5001D random access memory. The tests included functional tests, AC and DC parametric tests, AC parametric worst-case pattern selection test, determination of worst-case transition for setup and hold times, and a series of schmoo plots. Average input high current, worst case input high current, output low current, and data setup time are some of the results presented.

  8. Electrical Evaluation of RCA MWS5001D Random Access Memory, Volume 4, Appendix C

    NASA Technical Reports Server (NTRS)

    Klute, A.

    1979-01-01

    The electrical characterization and qualification test results are presented for the RCA MWS5001D random access memory. The tests included functional tests, AC and DC parametric tests, AC parametric worst-case pattern selection test, determination of worst-case transition for setup and hold times, and a series of schmoo plots. Statistical analysis data is supplied along with write pulse width, read cycle time, write cycle time, and chip enable time data.

  9. An Accessible Two-Dimensional Solution Nuclear Magnetic Resonance Experiment on Human Ubiquitin

    ERIC Educational Resources Information Center

    Rovnyak, David; Thompson, Laura E.

    2005-01-01

    Solution-state nuclear magnetic resonance (NMR) is an invaluable tool in structural and molecular biology research, but may be underutilized in undergraduate laboratories because instrumentation for performing structural studies of macromolecules in aqueous solutions is not yet widely available for use in undergraduate laboratories. We have…

  10. Magnetic Force and Work: An Accessible Example

    ERIC Educational Resources Information Center

    Gates, Joshua

    2014-01-01

    Despite their physics instructors' arguments to the contrary, introductory students can observe situations in which there seems to be compelling evidence for magnetic force doing work. The counterarguments are often highly technical and require physics knowledge beyond the experience of novice students, however. A simple example is presented…

  11. Playing the Smart Card.

    ERIC Educational Resources Information Center

    Zuzack, Christine A.

    1997-01-01

    Enhanced magnetic strip cards and "smart cards" offer varied service options to college students. Enhanced magnetic strip cards serve as cash cards and provide access to services. Smart cards, which resemble credit cards but contain a microchip, can be used as phone cards, bus passes, library cards, admission tickets, point-of-sale debit…

  12. Device for plasma confinement and heating by high currents and nonclassical plasma transport properties

    DOEpatents

    Coppi, B.; Montgomery, D.B.

    1973-12-11

    A toroidal plasma containment device having means for inducing high total plasma currents and current densities and at the same time emhanced plasma heating, strong magnetic confinement, high energy density containment, magnetic modulation, microwaveinduced heating, and diagnostic accessibility is described. (Official Gazette)

  13. Magnet Schools. ERIC Digest Series Number EA 26.

    ERIC Educational Resources Information Center

    Klauke, Amy

    In order to facilitate the transition to a multiracial community and to meet the prevailing desire for academic excellence, magnet schools have arisen in urban areas throughout the country. These schools meet racial quotas through voluntary enrollment and open access, promote integration through cooperative learning practices, emphasize personal…

  14. Random Access Memories: A New Paradigm for Target Detection in High Resolution Aerial Remote Sensing Images.

    PubMed

    Zou, Zhengxia; Shi, Zhenwei

    2018-03-01

    We propose a new paradigm for target detection in high resolution aerial remote sensing images under small target priors. Previous remote sensing target detection methods frame the detection as learning of detection model + inference of class-label and bounding-box coordinates. Instead, we formulate it from a Bayesian view that at inference stage, the detection model is adaptively updated to maximize its posterior that is determined by both training and observation. We call this paradigm "random access memories (RAM)." In this paradigm, "Memories" can be interpreted as any model distribution learned from training data and "random access" means accessing memories and randomly adjusting the model at detection phase to obtain better adaptivity to any unseen distribution of test data. By leveraging some latest detection techniques e.g., deep Convolutional Neural Networks and multi-scale anchors, experimental results on a public remote sensing target detection data set show our method outperforms several other state of the art methods. We also introduce a new data set "LEarning, VIsion and Remote sensing laboratory (LEVIR)", which is one order of magnitude larger than other data sets of this field. LEVIR consists of a large set of Google Earth images, with over 22 k images and 10 k independently labeled targets. RAM gives noticeable upgrade of accuracy (an mean average precision improvement of 1% ~ 4%) of our baseline detectors with acceptable computational overhead.

  15. MAGNETIC VT study: a prospective, multicenter, post-market randomized controlled trial comparing VT ablation outcomes using remote magnetic navigation-guided substrate mapping and ablation versus manual approach in a low LVEF population.

    PubMed

    Di Biase, Luigi; Tung, Roderick; Szili-Torok, Tamás; Burkhardt, J David; Weiss, Peter; Tavernier, Rene; Berman, Adam E; Wissner, Erik; Spear, William; Chen, Xu; Neužil, Petr; Skoda, Jan; Lakkireddy, Dhanunjaya; Schwagten, Bruno; Lock, Ken; Natale, Andrea

    2017-04-01

    Patients with ischemic cardiomyopathy (ICM) are prone to scar-related ventricular tachycardia (VT). The success of VT ablation depends on accurate arrhythmogenic substrate localization, followed by optimal delivery of energy provided by constant electrode-tissue contact. Current manual and remote magnetic navigation (RMN)-guided ablation strategies aim to identify a reentry circuit and to target a critical isthmus through activation and entrainment mapping during ongoing tachycardia. The MAGNETIC VT trial will assess if VT ablation using the Niobe™ ES magnetic navigation system results in superior outcomes compared to a manual approach in subjects with ischemic scar VT and low ejection fraction. This is a randomized, single-blind, prospective, multicenter post-market study. A total of 386 subjects (193 per group) will be enrolled and randomized 1:1 between treatment with the Niobe ES system and treatment via a manual procedure at up to 20 sites. The study population will consist of patients with ischemic cardiomyopathy with left ventricular ejection fraction (LVEF) of ≤35% and implantable cardioverter defibrillator (ICD) who have sustained monomorphic VT. The primary study endpoint is freedom from any recurrence of VT through 12 months. The secondary endpoints are acute success; freedom from any VT at 1 year in a large-scar subpopulation; procedure-related major adverse events; and mortality rate through 12-month follow-up. Follow-up will consist of visits at 3, 6, 9, and 12 months, all of which will include ICD interrogation. The MAGNETIC VT trial will help determine whether substrate-based ablation of VT with RMN has clinical advantages over manual catheter manipulation. Clinicaltrials.gov identifier: NCT02637947.

  16. Dynamical properties of the S =1/2 random Heisenberg chain

    NASA Astrophysics Data System (ADS)

    Shu, Yu-Rong; Dupont, Maxime; Yao, Dao-Xin; Capponi, Sylvain; Sandvik, Anders W.

    2018-03-01

    We study dynamical properties at finite temperature (T ) of Heisenberg spin chains with random antiferromagnetic exchange couplings, which realize the random singlet phase in the low-energy limit, using three complementary numerical methods: exact diagonalization, matrix-product-state algorithms, and stochastic analytic continuation of quantum Monte Carlo results in imaginary time. Specifically, we investigate the dynamic spin structure factor S (q ,ω ) and its ω →0 limit, which are closely related to inelastic neutron scattering and nuclear magnetic resonance (NMR) experiments (through the spin-lattice relaxation rate 1 /T1 ). Our study reveals a continuous narrow band of low-energy excitations in S (q ,ω ) , extending throughout the q space, instead of being restricted to q ≈0 and q ≈π as found in the uniform system. Close to q =π , the scaling properties of these excitations are well captured by the random-singlet theory, but disagreements also exist with some aspects of the predicted q dependence further away from q =π . Furthermore we also find spin diffusion effects close to q =0 that are not contained within the random-singlet theory but give non-negligible contributions to the mean 1 /T1 . To compare with NMR experiments, we consider the distribution of the local relaxation rates 1 /T1 . We show that the local 1 /T1 values are broadly distributed, approximately according to a stretched exponential. The mean 1 /T1 first decreases with T , but below a crossover temperature it starts to increase and likely diverges in the limit of a small nuclear resonance frequency ω0. Although a similar divergent behavior has been predicted and experimentally observed for the static uniform susceptibility, this divergent behavior of the mean 1 /T1 has never been experimentally observed. Indeed, we show that the divergence of the mean 1 /T1 is due to rare events in the disordered chains and is concealed in experiments, where the typical 1 /T1 value is accessed.

  17. Generation of flat-top pulsed magnetic fields with feedback control approach.

    PubMed

    Kohama, Yoshimitsu; Kindo, Koichi

    2015-10-01

    We describe the construction of a simple, compact, and cost-effective feedback system that produces flat-top field profiles in pulsed magnetic fields. This system is designed for use in conjunction with a typical capacitor-bank driven pulsed magnet and was tested using a 60-T pulsed magnet. With the developed feedback controller, we have demonstrated flat-top magnetic fields as high as 60.64 T with an excellent field stability of ±0.005 T. The result indicates that the flat-top pulsed magnetic field produced features high field stability and an accessible field strength. These features make this system useful for improving the resolution of data with signal averaging.

  18. New vibration-assisted magnetic abrasive polishing (VAMAP) method for microstructured surface finishing.

    PubMed

    Guo, Jiang; Kum, Chun Wai; Au, Ka Hing; Tan, Zhi'En Eddie; Wu, Hu; Liu, Kui

    2016-06-13

    In order to polish microstructured surface without deteriorating its profile, we propose a new vibration-assisted magnetic abrasive polishing (VAMAP) method. In this method, magnetic force guarantees that the magnetic abrasives can well contact the microstructured surface and access the corners of microstructures while vibration produces a relative movement between microstructures and magnetic abrasives. As the vibration direction is parallel to the microstructures, the profile of the microstructures will not be deteriorated. The relation between vibration and magnetic force was analyzed and the feasibility of this method was experimentally verified. The results show that after polishing, the surface finish around microstructures was significantly improved while the profile of microstructures was well maintained.

  19. Chirality-induced magnon transport in AA-stacked bilayer honeycomb chiral magnets.

    PubMed

    Owerre, S A

    2016-11-30

    In this Letter, we study the magnetic transport in AA-stacked bilayer honeycomb chiral magnets coupled either ferromagnetically or antiferromagnetically. For both couplings, we observe chirality-induced gaps, chiral protected edge states, magnon Hall and magnon spin Nernst effects of magnetic spin excitations. For ferromagnetically coupled layers, thermal Hall and spin Nernst conductivities do not change sign as function of magnetic field or temperature similar to single-layer honeycomb ferromagnetic insulator. In contrast, for antiferromagnetically coupled layers, we observe a sign change in the thermal Hall and spin Nernst conductivities as the magnetic field is reversed. We discuss possible experimental accessible honeycomb bilayer quantum materials in which these effects can be observed.

  20. Magnetic properties of spinels GeNi2-xCoxO4 systems: Green's function and high-temperature series expansions

    NASA Astrophysics Data System (ADS)

    El Grini, A.; Salmi, S.; Masrour, R.; Hamedoun, M.; Bouslykhane, K.; Marzouk, A.; Hourmatallah, A.; Benzakour, N.

    2018-06-01

    The Green's function theory and high-temperature series expansions technical have been developed for magnetic systems GeNi2-xCoxO4. We have applied the Green's function theory to evaluate thermal magnetization and magnetic susceptibility for different values of magnetic field and dilution x, considering all components of the magnetization when an external magnetic field is applied in (x,z)-plane. The second theory combined with the Padé approximants method for a randomly diluted Heisenberg magnet is used to deduce the magnetic phase diagram of GeNi2 - xCoxO4 systems. The critical exponents ? and ? associated with the magnetic susceptibility ? and the correlation length ξ, respectively, have been deduced. The theoretical results are compared with those given by magnetic measurements.

  1. Embedding a randomized clinical trial into an ongoing registry infrastructure: unique opportunities for efficiency in design of the Study of Access site For Enhancement of Percutaneous Coronary Intervention for Women (SAFE-PCI for Women).

    PubMed

    Hess, Connie N; Rao, Sunil V; Kong, David F; Aberle, Laura H; Anstrom, Kevin J; Gibson, C Michael; Gilchrist, Ian C; Jacobs, Alice K; Jolly, Sanjit S; Mehran, Roxana; Messenger, John C; Newby, L Kristin; Waksman, Ron; Krucoff, Mitchell W

    2013-09-01

    Women are at higher risk than men for bleeding and vascular complications after percutaneous coronary intervention (PCI). Compared with femoral access, radial access reduces these complications but may be more challenging in women because of higher rates of radial artery spasm, tortuosity, and occlusion as well as lower rates of procedure success. Whether the safety advantages of radial versus femoral access in women undergoing PCI are outweighed by reduced effectiveness has not been studied. The Study of Access site For Enhancement of PCI for Women is a prospective, randomized clinical trial comparing radial with femoral arterial access in women undergoing PCI. In conjunction with the US Food and Drug Administration's Critical Path Cardiac Safety Research Consortium, this study embeds the randomized clinical trial into the existing infrastructure of the National Cardiovascular Data Registry CathPCI Registry through the National Institute of Health's National Cardiovascular Research Infrastructure. The primary efficacy end point is a composite of bleeding (Bleeding Academic Research Consortium types 2, 3, or 5) or vascular complication requiring intervention occurring at 72 hours after PCI or by hospital discharge. The primary feasibility end point is procedure success. Secondary end points include procedure duration, contrast volume, radiation dose, quality of life, and a composite of 30-day death, vascular complication, or unplanned revascularization. © 2013.

  2. A Randomized Cadaver Study Comparing First-Attempt Success Between Tibial and Humeral Intraosseous Insertions Using NIO Device by Paramedics: A Preliminary Investigation.

    PubMed

    Szarpak, Lukasz; Truszewski, Zenon; Smereka, Jacek; Krajewski, Paweł; Fudalej, Marcin; Adamczyk, Piotr; Czyzewski, Lukasz

    2016-05-01

    Medical personnel may encounter difficulties in obtaining intravenous (IV) access during cardiac arrest. The 2015 American Heart Association guidelines and the 2015 European Resuscitation Council guidelines for cardiopulmonary resuscitation (CPR) suggest that rescuers establish intraosseous (IO) access if an IV line is not easily obtainable.The aim of the study was to compare the success rates of the IO proximal tibia and proximal humerus head access performed by paramedics using the New Intraosseous access device (NIO; Persys Medical, Houston, TX, USA) in an adult cadaver model during simulated CPR.In an interventional, randomized, crossover, single-center cadaver study, a semi-automatic spring-load driven NIO access device was investigated. In total, 84 paramedics with less than 5-year experience in Emergency Medical Service participated in the study. The trial was performed on 42 adult cadavers. In each cadaver, 2 IO accesses to the humerus head, and 2 IO accesses to the proximal tibia were obtained.The success rate of the first IO attempt was 89.3% (75/84) for tibial access, and 73.8% (62/84) for humeral access (P = 0.017). The procedure times were significantly faster for tibial access [16.8 (interquartile range, IQR, 15.1-19.9] s] than humeral access [26.7 (IQR, 22.1-30.9) s] (P < 0.001).Tibial IO access is easier and faster to put in place than humeral IO access. Humeral IO access can be an alternative method to tibial IO access. clinicaltrials.gov Identifier: NCT02700867.

  3. Correction to: Thermal Expansion, Elastic and Magnetic Properties of FeCoNiCu-Based High-Entropy Alloys Using First-Principle Theory

    NASA Astrophysics Data System (ADS)

    Huang, Shuo; Vida, Ádám; Heczel, Anita; Holmström, Erik; Vitos, Levente

    2018-02-01

    This article was originally published Online First without open access. After publication in volume 69, issue 11, page 2107-2112 the author decided to opt for Open Choice and to make the article an open access publication.

  4. Erratum: Correction to: Thermal Expansion, Elastic and Magnetic Properties of FeCoNiCu-Based High-Entropy Alloys Using First-Principle Theory

    NASA Astrophysics Data System (ADS)

    Huang, Shuo; Vida, Ádám; Heczel, Anita; Holmström, Erik; Vitos, Levente

    2018-06-01

    This article was originally published Online First without open access. After publication in volume 69, issue 11, page 2107-2112 the author decided to opt for Open Choice and to make the article an open access publication.

  5. Prospective Durability Testing of a Vascular Access Phantom

    DTIC Science & Technology

    2010-09-01

    ultrasound guidance when obtaining central venous access.19,20 The increasing use of ultrasound guidance for vascular access has created an educational...with difficult intravenous access. Ann Emerg Med. 2005;46:456-61. 7. Gallieni M, Cozzolino M. Uncomplicated central vein catheterization of high risk...al. Randomized, controlled clinical trial of point-of-care limited ultrasonography assistance of central venous cannulation: The third sonography

  6. Progressive magnetic softening of ferromagnetic layers in multilayer ferromagnet-nonmagnet systems and the role of granularity

    NASA Astrophysics Data System (ADS)

    Sahu, Siddharth S.; Siva, Vantari; Pradhan, Paresh C.; Nayak, Maheswar; Senapati, Kartik; Sahoo, Pratap K.

    2017-06-01

    We report a study of the structural and magnetic behavior of the topmost magnetic layer in a ferromagnet-nonmagnet (Co-Au) multilayer system. Glancing angle X-ray diffraction measurements performed on a series of multilayers showed a gradual decrease in the grain size of the topmost magnetic layer with the increasing number of bilayers. Concurrently, the magnetic hardness and magneto-crystalline anisotropy of the top Co layer were found to decrease, as observed by magneto-optical Kerr effect measurements. This magnetic softening has been discussed in the light of Herzer's random anisotropy model. Micromagnetic simulations of the multilayer system also corroborated these observations.

  7. Semiconducting double-dot exchange-only qubit dynamics in the presence of magnetic and charge noises

    NASA Astrophysics Data System (ADS)

    Ferraro, E.; Fanciulli, M.; De Michielis, M.

    2018-06-01

    The effects of magnetic and charge noises on the dynamical evolution of the double-dot exchange-only qubit (DEOQ) is theoretically investigated. The DEOQ consisting of three electrons arranged in an electrostatically defined double quantum dot deserves special interest in quantum computation applications. Its advantages are in terms of fabrication, control and manipulation in view of implementation of fast single and two-qubit operations through only electrical tuning. The presence of the environmental noise due to nuclear spins and charge traps, in addition to fluctuations in the applied magnetic field and charge fluctuations on the electrostatic gates adopted to confine the electrons, is taken into account including random magnetic field and random coupling terms in the Hamiltonian. The behavior of the return probability as a function of time for initial conditions of interest is presented. Moreover, through an envelope-fitting procedure on the return probabilities, coherence times are extracted when model parameters take values achievable experimentally in semiconducting devices.

  8. Random-access scanning microscopy for 3D imaging in awake behaving animals

    PubMed Central

    Nadella, K. M. Naga Srinivas; Roš, Hana; Baragli, Chiara; Griffiths, Victoria A.; Konstantinou, George; Koimtzis, Theo; Evans, Geoffrey J.; Kirkby, Paul A.; Silver, R. Angus

    2018-01-01

    Understanding how neural circuits process information requires rapid measurements from identified neurons distributed in 3D space. Here we describe an acousto-optic lens two-photon microscope that performs high-speed focussing and line-scanning within a volume spanning hundreds of micrometres. We demonstrate its random access functionality by selectively imaging cerebellar interneurons sparsely distributed in 3D and by simultaneously recording from the soma, proximal and distal dendrites of neocortical pyramidal cells in behaving mice. PMID:27749836

  9. Mathematic Model of Digital Control System with PID Regulator and Regular Step of Quantization with Information Transfer via the Channel of Plural Access

    NASA Astrophysics Data System (ADS)

    Abramov, G. V.; Emeljanov, A. E.; Ivashin, A. L.

    Theoretical bases for modeling a digital control system with information transfer via the channel of plural access and a regular quantization cycle are submitted. The theory of dynamic systems with random changes of the structure including elements of the Markov random processes theory is used for a mathematical description of a network control system. The characteristics of similar control systems are received. Experimental research of the given control systems is carried out.

  10. Effects of vibration and shock on the performance of gas-bearing space-power Brayton cycle turbomachinery. Part 3: Sinusoidal and random vibration data reduction and evaluation, and random vibration probability analysis

    NASA Technical Reports Server (NTRS)

    Tessarzik, J. M.; Chiang, T.; Badgley, R. H.

    1973-01-01

    The random vibration response of a gas bearing rotor support system has been experimentally and analytically investigated in the amplitude and frequency domains. The NASA Brayton Rotating Unit (BRU), a 36,000 rpm, 10 KWe turbogenerator had previously been subjected in the laboratory to external random vibrations, and the response data recorded on magnetic tape. This data has now been experimentally analyzed for amplitude distribution and magnetic tape. This data has now been experimentally analyzed for amplitude distribution and frequency content. The results of the power spectral density analysis indicate strong vibration responses for the major rotor-bearing system components at frequencies which correspond closely to their resonant frequencies obtained under periodic vibration testing. The results of amplitude analysis indicate an increasing shift towards non-Gaussian distributions as the input level of external vibrations is raised. Analysis of axial random vibration response of the BRU was performed by using a linear three-mass model. Power spectral densities, the root-mean-square value of the thrust bearing surface contact were calculated for specified input random excitation.

  11. Magnetic vortex racetrack memory

    NASA Astrophysics Data System (ADS)

    Geng, Liwei D.; Jin, Yongmei M.

    2017-02-01

    We report a new type of racetrack memory based on current-controlled movement of magnetic vortices in magnetic nanowires with rectangular cross-section and weak perpendicular anisotropy. Data are stored through the core polarity of vortices and each vortex carries a data bit. Besides high density, non-volatility, fast data access, and low power as offered by domain wall racetrack memory, magnetic vortex racetrack memory has additional advantages of no need for constrictions to define data bits, changeable information density, adjustable current magnitude for data propagation, and versatile means of ultrafast vortex core switching. By using micromagnetic simulations, current-controlled motion of magnetic vortices in cobalt nanowire is demonstrated for racetrack memory applications.

  12. False Operation of Static Random Access Memory Cells under Alternating Current Power Supply Voltage Variation

    NASA Astrophysics Data System (ADS)

    Sawada, Takuya; Takata, Hidehiro; Nii, Koji; Nagata, Makoto

    2013-04-01

    Static random access memory (SRAM) cores exhibit susceptibility against power supply voltage variation. False operation is investigated among SRAM cells under sinusoidal voltage variation on power lines introduced by direct RF power injection. A standard SRAM core of 16 kbyte in a 90 nm 1.5 V technology is diagnosed with built-in self test and on-die noise monitor techniques. The sensitivity of bit error rate is shown to be high against the frequency of injected voltage variation, while it is not greatly influenced by the difference in frequency and phase against SRAM clocking. It is also observed that the distribution of false bits is substantially random in a cell array.

  13. A random access memory immune to single event upset using a T-Resistor

    DOEpatents

    Ochoa, A. Jr.

    1987-10-28

    In a random access memory cell, a resistance ''T'' decoupling network in each leg of the cell reduces random errors caused by the interaction of energetic ions with the semiconductor material forming the cell. The cell comprises two parallel legs each containing a series pair of complementary MOS transistors having a common gate connected to the node between the transistors of the opposite leg. The decoupling network in each leg is formed by a series pair of resistors between the transistors together with a third resistor interconnecting the junction between the pair of resistors and the gate of the transistor pair forming the opposite leg of the cell. 4 figs.

  14. Random access memory immune to single event upset using a T-resistor

    DOEpatents

    Ochoa, Jr., Agustin

    1989-01-01

    In a random access memory cell, a resistance "T" decoupling network in each leg of the cell reduces random errors caused by the interaction of energetic ions with the semiconductor material forming the cell. The cell comprises two parallel legs each containing a series pair of complementary MOS transistors having a common gate connected to the node between the transistors of the opposite leg. The decoupling network in each leg is formed by a series pair of resistors between the transistors together with a third resistor interconnecting the junction between the pair of resistors and the gate of the transistor pair forming the opposite leg of the cell.

  15. The Role of Access to Head Start and Quality Ratings for Spanish-Speaking Dual Language Learners’ (DLLs) Participation in Early Childhood Education

    PubMed Central

    2014-01-01

    Data from the Head Start Impact Study (N = 4,442) were used to test for differences between Spanish-speaking Dual Language Learners (DLLs) and monolingual English-speaking children in: (1) Head Start attendance rates when randomly assigned admission; and (2) quality ratings of other early childhood education (ECE) programs attended when not randomly assigned admission to Head Start. Logistic regressions showed that Spanish-speaking DLL children randomly assigned a spot in Head Start were more likely than monolingual-English learners to attend. Further, Spanish-speaking DLLs not randomly assigned a spot in Head Start were more likely to attend higher-quality ECE centers than non-DLL children. Policy implications are discussed, suggesting that, if given access, Spanish-speaking DLL families will take advantage of quality ECE programs. PMID:25018585

  16. Random Telegraph Signal-Like Fluctuation Created by Fowler-Nordheim Stress in Gate Induced Drain Leakage Current of the Saddle Type Dynamic Random Access Memory Cell Transistor

    NASA Astrophysics Data System (ADS)

    Kim, Heesang; Oh, Byoungchan; Kim, Kyungdo; Cha, Seon-Yong; Jeong, Jae-Goan; Hong, Sung-Joo; Lee, Jong-Ho; Park, Byung-Gook; Shin, Hyungcheol

    2010-09-01

    We generated traps inside gate oxide in gate-drain overlap region of recess channel type dynamic random access memory (DRAM) cell transistor through Fowler-Nordheim (FN) stress, and observed gate induced drain leakage (GIDL) current both in time domain and in frequency domain. It was found that the trap inside gate oxide could generate random telegraph signal (RTS)-like fluctuation in GIDL current. The characteristics of that fluctuation were similar to those of RTS-like fluctuation in GIDL current observed in the non-stressed device. This result shows the possibility that the trap causing variable retention time (VRT) in DRAM data retention time can be located inside gate oxide like channel RTS of metal-oxide-semiconductor field-effect transistors (MOSFETs).

  17. School Web Sites: Are They Accessible to All?

    ERIC Educational Resources Information Center

    Wells, Julie A.; Barron, Ann E.

    2006-01-01

    In 2002, the National Center for Educational Statistics reported that 99% of public schools had Internet access and 86% of those schools had a web site or web page (Kleiner & Lewis, 2003). This study examined accessibility issues on elementary school homepages. Using a random sample of elementary school web sites, the researchers documented…

  18. Ground state structure of random magnets

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Bastea, S.; Duxbury, P.M.

    1998-10-01

    Using exact optimization methods, we find all of the ground states of ({plus_minus}h) random-field Ising magnets (RFIM) and of dilute antiferromagnets in a field (DAFF). The degenerate ground states are usually composed of isolated clusters (two-level systems) embedded in a frozen background. We calculate the paramagnetic response (sublattice response) and the ground state entropy for the RFIM (DAFF) due to these clusters. In both two and three dimensions there is a broad regime in which these quantities are strictly positive, even at irrational values of h/J (J is the exchange constant). {copyright} {ital 1998} {ital The American Physical Society}

  19. Sharing Resources In Mobile/Satellite Communications

    NASA Technical Reports Server (NTRS)

    Yan, Tsun-Yee; Sue, Miles K.

    1992-01-01

    Report presents preliminary theoretical analysis of several alternative schemes for allocation of satellite resource among terrestrial subscribers of landmobile/satellite communication system. Demand-access and random-access approaches under code-division and frequency-division concepts compared.

  20. Nanocluster building blocks of artificial square spin ice: Stray-field studies of thermal dynamics

    NASA Astrophysics Data System (ADS)

    Pohlit, Merlin; Porrati, Fabrizio; Huth, Michael; Ohno, Yuzo; Ohno, Hideo; Müller, Jens

    2015-05-01

    We present measurements of the thermal dynamics of a Co-based single building block of an artificial square spin ice fabricated by focused electron-beam-induced deposition. We employ micro-Hall magnetometry, an ultra-sensitive tool to study the stray field emanating from magnetic nanostructures, as a new technique to access the dynamical properties during the magnetization reversal of the spin-ice nanocluster. The obtained hysteresis loop exhibits distinct steps, displaying a reduction of their "coercive field" with increasing temperature. Therefore, thermally unstable states could be repetitively prepared by relatively simple temperature and field protocols allowing one to investigate the statistics of their switching behavior within experimentally accessible timescales. For a selected switching event, we find a strong reduction of the so-prepared states' "survival time" with increasing temperature and magnetic field. Besides the possibility to control the lifetime of selected switching events at will, we find evidence for a more complex behavior caused by the special spin ice arrangement of the macrospins, i.e., that the magnetic reversal statistically follows distinct "paths" most likely driven by thermal perturbation.

  1. The Mechanism for Energy Buildup in the Solar Corona

    NASA Astrophysics Data System (ADS)

    Antiochos, Spiro; Knizhnik, Kalman; DeVore, Richard

    2017-10-01

    Magnetic reconnection and helicity conservation are two of the most important basic processes determining the structure and dynamics of laboratory and space plasmas. The most energetic dynamics in the solar system are the giant CMEs/flares that produce the most dangerous space weather at Earth, yet may also have been essential for the origin of life. The origin of these explosions is that the lowest-lying magnetic flux in the Sun's corona undergoes the continual buildup of stress and free energy that can be released only through explosive ejection. We perform MHD simulations of a coronal volume driven by quasi-random boundary flows designed to model the processes by which the solar interior drives the corona. Our simulations are uniquely accurate in preserving magnetic helicity. We show that even though small-scale stress is injected randomly throughout the corona, the net result of magnetic reconnection is a coherent stressing of the lowest-lying field lines. This highly counter-intuitive result - magnetic stress builds up locally rather than spreading out to a minimum energy state - is the fundamental mechanism responsible for the Sun's magnetic explosions. It is likely to be a mechanism that is ubiquitous throughout laboratory and space plasmas. This work was supported by the NASA LWS and SR Programs.

  2. Magnetic field effect on growth, arsenic uptake, and total amylolytic activity on mesquite (Prosopis juliflora x P. velutina) seeds

    NASA Astrophysics Data System (ADS)

    Flores-Tavizón, Edith; Mokgalaka-Matlala, Ntebogeng S.; Elizalde Galindo, José T.; Castillo-Michelle, Hiram; Peralta-Videa, Jose R.; Gardea-Torresdey, Jorge L.

    2012-04-01

    Magnetic field is closely related to the cell metabolism of plants [N. A. Belyavskaya, Adv. Space Res. 34, 1566 (2004)]. In order to see the effect of magnetic field on the plant growth, arsenic uptake, and total amylolytic activity of mesquite (Prosopis juliflora x P. velutina) seeds, ten sets of 80 seeds were selected to be oriented with the long axis parallel or randomly oriented to an external magnetic field. The external magnetic field magnitude was 1 T, and the exposition time t = 30 min. Then, the seeds were stored for three days in a plastic bag and then sown on paper towels in a modified Hoagland's nutrient solution. After three days of germination in the dark and three days in light, seedlings were grown hydroponically in modified Hoagland's nutrient solution (high PO42-) containing 0, 10, or 20 ppm of arsenic as As (III) and (V). The results show that the germination ratios, growth, elongation, arsenic uptake, and total amylolytic activity of the long axis oriented mesquite seeds were much higher than those of the randomly oriented seeds. Also, these two sets of seeds showed higher properties than the ones that were not exposed to external magnetic field.

  3. The Impact of Preoperative α-Adrenergic Antagonists on Ureteral Access Sheath Insertion Force and the Upper Limit of Force Required to Avoid Ureteral Mucosal Injury: A Randomized Controlled Study.

    PubMed

    Koo, Kyo Chul; Yoon, Jun-Ho; Park, No-Cheol; Lee, Hye Sun; Ahn, Hyun Kyu; Lee, Kwang Suk; Kim, Do Kyung; Cho, Kang Su; Chung, Byung Ha; Hong, Chang Hee

    2018-06-01

    Excessive bulking force during primary access of the ureteral access sheath may induce ureteral injury. We investigated the efficacy of preoperative α-blockade to reduce ureteral access sheath insertion force and determine the upper limit required to avoid ureteral injury. In this randomized controlled trial 135 patients from a single institution who had ureteropelvic junction or renal pelvis stones and were scheduled to undergo retrograde intrarenal surgery were prospectively enrolled from December 2015 to January 2017. Of the patients 41 and 42 were randomly assigned to the control and experimental groups, respectively. The experimental group received α-blockade preoperatively. The 21 patients who were pre-stented were assessed separately. We developed a homemade device to measure maximal ureteral access sheath insertion force. Our ureteral access sheath insertion force measurement device showed excellent reproducibility. Higher insertion velocity resulted in greater maximal sheath insertion force. Maximal insertion force in the α-blockade group was significantly lower than in the control group at the ureterovesical junction (p = 0.008) and the proximal ureter (p = 0.036). Maximal insertion force in the α-blockade group was comparable to that in pre-stented patients. Female patients and patients 70 years old or older showed a lower maximal ureteral access sheath insertion force than their counterparts. The rate of grade 2 or greater ureteral injury was lower in the α-blockade group than in controls (p = 0.038). No injury occurred in any case in which ureteral access sheath insertion force did not exceed 600 G. Preoperative α-blockade and slow sheath placement may reduce maximal ureteral access sheath insertion force. If the force exceeds 600 G, a smaller diameter sheath may be an alternative. Alternatively the procedure can be terminated and followed later by pre-stented retrograde intrarenal surgery. Copyright © 2018 American Urological Association Education and Research, Inc. Published by Elsevier Inc. All rights reserved.

  4. A multi-level intervention in worksites to increase fruit and vegetable access and intake: Rationale, design and methods of the 'Good to Go' cluster randomized trial.

    PubMed

    Risica, Patricia M; Gorham, Gemma; Dionne, Laura; Nardi, William; Ng, Doug; Middler, Reese; Mello, Jennifer; Akpolat, Rahmet; Gettens, Katelyn; Gans, Kim M

    2018-02-01

    Fruit and vegetable (F&V) consumption is an important contributor to chronic disease prevention. However, most Americans do not eat adequate amounts. The worksite is an advantageous setting to reach large, diverse segments of the population with interventions to increase F&V intake, but research gaps exist. No studies have evaluated the implementation of mobile F&V markets at worksites nor compared the effectiveness of such markets with or without nutrition education. This paper describes the protocol for Good to Go (GTG), a cluster randomized trial to evaluate F&V intake change in employees from worksites randomized into three experimental arms: discount, fresh F&V markets (Access Only arm); markets plus educational components including campaigns, cooking demonstrations, videos, newsletters, and a web site (Access Plus arm); and an attention placebo comparison intervention on physical activity and stress reduction (Comparison). Secondary aims include: 1) Process evaluation to determine costs, reach, fidelity, and dose as well as the relationship of these variables with changes in F&V intake; 2) Applying a mediating variable framework to examine relationships of psychosocial factors/determinants with changes in F&V consumption; and 3) Cost effectiveness analysis of the different intervention arms. The GTG study will fill important research gaps in the field by implementing a rigorous cluster randomized trial to evaluate the efficacy of an innovative environmental intervention providing access and availability to F&V at the worksite and whether this access intervention is further enhanced by accompanying educational interventions. GTG will provide an important contribution to public health research and practice. Trial registration number NCT02729675, ClinicalTrials.gov. Copyright © 2017 The Authors. Published by Elsevier Inc. All rights reserved.

  5. A multi-level intervention in worksites to increase fruit and vegetable access and intake: Rationale, design and methods of the ‘Good to Go’ cluster randomized trial

    PubMed Central

    Risica, Patricia M.; Gorham, Gemma; Dionne, Laura; Nardi, William; Ng, Doug; Middler, Reese; Mello, Jennifer; Akpolat, Rahmet; Gettens, Katelyn; Gans, Kim M.

    2018-01-01

    Background Fruit and vegetable (F&V) consumption is an important contributor to chronic disease prevention. However, most Americans do not eat adequate amounts. The worksite is an advantageous setting to reach large, diverse segments of the population with interventions to increase F&V intake, but research gaps exist. No studies have evaluated the implementation of mobile F&V markets at worksites nor compared the effectiveness of such markets with or without nutrition education. Methods This paper describes the protocol for Good to Go (GTG), a cluster randomized trial to evaluate F&V intake change in employees from worksites randomized into three experimental arms: discount, fresh F&V markets (Access Only arm); markets plus educational components including campaigns, cooking demonstrations, videos, newsletters, and a web site (Access Plus arm); and an attention placebo comparison intervention on physical activity and stress reduction (Comparison). Secondary aims include: 1) Process evaluation to determine costs, reach, fidelity, and dose as well as the relationship of these variables with changes in F&V intake; 2) Applying a mediating variable framework to examine relationships of psychosocial factors/determinants with changes in F&V consumption; and 3) Cost effectiveness analysis of the different intervention arms. Discussion The GTG study will fill important research gaps in the field by implementing a rigorous cluster randomized trial to evaluate the efficacy of an innovative environmental intervention providing access and availability to F&V at the worksite and whether this access intervention is further enhanced by accompanying educational interventions. GTG will provide an important contribution to public health research and practice. Trial registration number NCT02729675, ClinicalTrials.gov PMID:29242108

  6. Realisation of all 16 Boolean logic functions in a single magnetoresistance memory cell.

    PubMed

    Gao, Shuang; Yang, Guang; Cui, Bin; Wang, Shouguo; Zeng, Fei; Song, Cheng; Pan, Feng

    2016-07-07

    Stateful logic circuits based on next-generation nonvolatile memories, such as magnetoresistance random access memory (MRAM), promise to break the long-standing von Neumann bottleneck in state-of-the-art data processing devices. For the successful commercialisation of stateful logic circuits, a critical step is realizing the best use of a single memory cell to perform logic functions. In this work, we propose a method for implementing all 16 Boolean logic functions in a single MRAM cell, namely a magnetoresistance (MR) unit. Based on our experimental results, we conclude that this method is applicable to any MR unit with a double-hump-like hysteresis loop, especially pseudo-spin-valve magnetic tunnel junctions with a high MR ratio. Moreover, after simply reversing the correspondence between voltage signals and output logic values, this method could also be applicable to any MR unit with a double-pit-like hysteresis loop. These results may provide a helpful solution for the final commercialisation of MRAM-based stateful logic circuits in the near future.

  7. Band structure of the quaternary Heusler alloys ScMnFeSn and ScFeCoAl

    NASA Astrophysics Data System (ADS)

    Shanthi, N.; Teja, Y. N.; Shaji, Shephine M.; Hosamani, Shashikala; Divya, H. S.

    2018-04-01

    In our quest for materials with specific applications, a theoretical study plays an important role in predicting the properties of compounds. Heusler alloys or compounds are the most studied in this context. More recently, a lot of quaternary Heusler compounds are investigated for potential applications in fields like Spintronics. We report here our preliminary study of the alloys ScMnFeSn and ScFeCoAl, using the ab-initio linear muffin-tin orbital method within the atomic sphere approximation (LMTO-ASA). The alloy ScMnFeSn shows perfect half-metallicity, namely, one of the spins shows a metallic behaviour and the other spin shows semi-conducting behaviour. Such materials find application in devices such as the spin-transfer torque random access memory (STT-MRAM). In addition, the alloy ScMnFeSn is found to have an integral magnetic moment of 4 µB, as predicted by the Slater-Pauling rule. The alloy ScFeCoAl does not show half-metallicity.

  8. Iron oxide nanoparticle layer templated by polydopamine spheres: a novel scaffold toward hollow-mesoporous magnetic nanoreactors

    NASA Astrophysics Data System (ADS)

    Huang, Liang; Ao, Lijiao; Xie, Xiaobin; Gao, Guanhui; Foda, Mohamed F.; Su, Wu

    2014-12-01

    Superparamagnetic iron oxide nanoparticle layers with high packing density and controlled thickness were in situ deposited on metal-affinity organic templates (polydopamine spheres), via one-pot thermal decomposition. The as synthesized hybrid structure served as a facile nano-scaffold toward hollow-mesoporous magnetic carriers, through surfactant-assisted silica encapsulation and its subsequent calcination. Confined but accessible gold nanoparticles were successfully incorporated into these carriers to form a recyclable catalyst, showing quick magnetic response and a large surface area (642.5 m2 g-1). Current nano-reactors exhibit excellent catalytic performance and high stability in reduction of 4-nitrophenol, together with convenient magnetic separability and good reusability. The integration of compact iron oxide nanoparticle layers with programmable polydopamine templates paves the way to fabricate magnetic-response hollow structures, with high permeability and multi-functionality.Superparamagnetic iron oxide nanoparticle layers with high packing density and controlled thickness were in situ deposited on metal-affinity organic templates (polydopamine spheres), via one-pot thermal decomposition. The as synthesized hybrid structure served as a facile nano-scaffold toward hollow-mesoporous magnetic carriers, through surfactant-assisted silica encapsulation and its subsequent calcination. Confined but accessible gold nanoparticles were successfully incorporated into these carriers to form a recyclable catalyst, showing quick magnetic response and a large surface area (642.5 m2 g-1). Current nano-reactors exhibit excellent catalytic performance and high stability in reduction of 4-nitrophenol, together with convenient magnetic separability and good reusability. The integration of compact iron oxide nanoparticle layers with programmable polydopamine templates paves the way to fabricate magnetic-response hollow structures, with high permeability and multi-functionality. Electronic supplementary information (ESI) available: Fig. S1-S5. See DOI: 10.1039/c4nr05931j

  9. Magnetic force and work: an accessible example

    NASA Astrophysics Data System (ADS)

    Gates, Joshua

    2014-05-01

    Despite their physics instructors’ arguments to the contrary, introductory students can observe situations in which there seems to be compelling evidence for magnetic force doing work. The counterarguments are often highly technical and require physics knowledge beyond the experience of novice students, however. A simple example is presented which can illustrate that all may not be what it seems when energy transfer and the magnetic force are involved. Excel and Python simulations of the process are also provided.

  10. A Close Look at a STEM-Themed Magnet and Its Experiential Program on the Occupational Identities, Career Maturity, and Access Provided to Low Socioeconomic Minority Students

    ERIC Educational Resources Information Center

    Reyes, Urlette

    2013-01-01

    The purpose of this study was to determine the effects of an experiential program on the occupational identity, access, and career maturity of Black and Latino students from low socioeconomic backgrounds. Data shows these students to be underrepresented in STEM fields. Student interest and access are noted in the literature to be amongst the…

  11. SDIO (Strategic Defense Initiative Office) Technical Information Management Center Bibliography of Unclassified Reports: January - December 1986.

    DTIC Science & Technology

    1986-12-01

    Classification. U Security Marks, Accession *:U00298 AD *. ADA096538 TITLE: Assessment of the Crossed Porro Prism Resonator AUTHOR. Seea, B.A.; Fueloep, K...Laser Range Finder Mechanical Property Stability Resonator Porro Prism Standord Mirror Examine Pgs: 16 Classification: U Security Marks: Accession...Gamma-Ray Laser Graser Mossbauer Effect Borrman Superradiance Nuclear-Magnetic Resonance Pgs: 26 Classification: U Security Marks: Accession *:U00484 AD

  12. Magnetic topology of Co-based inverse opal-like structures

    NASA Astrophysics Data System (ADS)

    Grigoryeva, N. A.; Mistonov, A. A.; Napolskii, K. S.; Sapoletova, N. A.; Eliseev, A. A.; Bouwman, W.; Byelov, D. V.; Petukhov, A. V.; Chernyshov, D. Yu.; Eckerlebe, H.; Vasilieva, A. V.; Grigoriev, S. V.

    2011-08-01

    The magnetic and structural properties of a cobalt inverse opal-like crystal have been studied by a combination of complementary techniques ranging from polarized neutron scattering and superconducting quantum interference device (SQUID) magnetometry to x-ray diffraction. Microradian small-angle x-ray diffraction shows that the inverse opal-like structure (OLS) synthesized by the electrochemical method fully duplicates the three-dimensional net of voids of the template artificial opal. The inverse OLS has a face-centered cubic (fcc) structure with a lattice constant of 640±10 nm and with a clear tendency to a random hexagonal close-packed structure along the [111] axes. Wide-angle x-ray powder diffraction shows that the atomic cobalt structure is described by coexistence of 95% hexagonal close-packed and 5% fcc phases. The SQUID measurements demonstrate that the inverse OLS film possesses easy-plane magnetization geometry with a coercive field of 14.0 ± 0.5 mT at room temperature. The detailed picture of the transformation of the magnetic structure under an in-plane applied field was detected with the help of small-angle diffraction of polarized neutrons. In the demagnetized state the magnetic system consists of randomly oriented magnetic domains. A complex magnetic structure appears upon application of the magnetic field, with nonhomogeneous distribution of magnetization density within the unit element of the OLS. This distribution is determined by the combined effect of the easy-plane geometry of the film and the crystallographic geometry of the opal-like structure with respect to the applied field direction.

  13. On-Chip Fluorescence Switching System for Constructing a Rewritable Random Access Data Storage Device.

    PubMed

    Nguyen, Hoang Hiep; Park, Jeho; Hwang, Seungwoo; Kwon, Oh Seok; Lee, Chang-Soo; Shin, Yong-Beom; Ha, Tai Hwan; Kim, Moonil

    2018-01-10

    We report the development of on-chip fluorescence switching system based on DNA strand displacement and DNA hybridization for the construction of a rewritable and randomly accessible data storage device. In this study, the feasibility and potential effectiveness of our proposed system was evaluated with a series of wet experiments involving 40 bits (5 bytes) of data encoding a 5-charactered text (KRIBB). Also, a flexible data rewriting function was achieved by converting fluorescence signals between "ON" and "OFF" through DNA strand displacement and hybridization events. In addition, the proposed system was successfully validated on a microfluidic chip which could further facilitate the encoding and decoding process of data. To the best of our knowledge, this is the first report on the use of DNA hybridization and DNA strand displacement in the field of data storage devices. Taken together, our results demonstrated that DNA-based fluorescence switching could be applicable to construct a rewritable and randomly accessible data storage device through controllable DNA manipulations.

  14. Nanoscale Reactive Ion Etching of Silicon Nitride Thin Films for Embedded Nanomagnetic Device Fabrication

    NASA Astrophysics Data System (ADS)

    Hibbard-Lubow, David Luke

    The demands of digital memory have increased exponentially in recent history, requiring faster, smaller and more accurate storage methods. Two promising solutions to this ever-present problem are Bit Patterned Media (BPM) and Spin-Transfer Torque Magnetic Random Access Memory (STT-MRAM). Producing these technologies requires difficult and expensive fabrication techniques. Thus, the production processes must be optimized to allow these storage methods to compete commercially while continuing to increase their information storage density and reliability. I developed a process for the production of nanomagnetic devices (which can take the form of several types of digital memory) embedded in thin silicon nitride films. My focus was on optimizing the reactive ion etching recipe required to embed the device in the film. Ultimately, I found that recipe 37 (Power: 250W, CF4 nominal/actual flow rate: 25/25.4 sccm, O2 nominal/actual flow rate: 3.1/5.2 sccm, which gave a maximum pressure around 400 mTorr) gave the most repeatable and anisotropic results. I successfully used processes described in this thesis to make embedded nanomagnets, which could be used as bit patterned media. Another promising application of this work is to make embedded magnetic tunneling junctions, which are the storage medium used in MRAM. Doing so will require still some tweaks to the fabrication methods. Techniques for making these changes and their potential effects are discussed.

  15. Co layer fragmentation effect on magnetoresistive and structural properties of nanogranular Co/Cu multilayers

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Spizzo, F.; Ronconi, F.; Ferrero, C.

    We deposited nanogranular Co/Cu multilayers made of thin fragmented Co layers separated by thicker Cu layers to study how the structure and the microstructure of magnetic nanogranular samples change as the average particle size is reduced and how these changes affect the giant magnetoresistive response of the samples. Indeed, thanks to the vertical periodicity of the structure, namely, to the fact that Co/Cu interfaces display an ordered stacking and are not randomly distributed within the samples as in conventional granular materials, their self-correlation and cross correlation can be investigated. In this way, the characteristic length scale of the Co/Cu interfacialmore » roughness that is strictly related to the giant magnetoresistive response of the samples and the universality class of the growth mechanism that affects the systems structure can be both accessed. The Co/Cu nanogranular multilayers were characterized using different x-ray techniques, from specular reflectivity, which allows to probe the multilayer development in the vertical direction, to grazing incidence small angle diffuse scattering, which provides information on the self-correlation and cross correlation of the Co/Cu interfaces. Furthermore, diffraction measurements indicate that the degree of structural disorder increases by decreasing the thickness of the Co layers. Magnetoresistive and magnetization measurements are as well presented and discussed with the results of the structural characterization.« less

  16. The efficacy of transcranial magnetic stimulation on migraine: a meta-analysis of randomized controlled trails.

    PubMed

    Lan, Lihuan; Zhang, Xiaoni; Li, Xiangpen; Rong, Xiaoming; Peng, Ying

    2017-08-22

    As a non-invasive therapy, whether transcranial magnetic stimulation (TMS) is effective on migraine. This article was aimed to assess the efficacy of TMS on migraine based on randomized controlled trails (RCTs). We searched PubMed, Embase and Cochrane Library electronic databases for published studies which compared TMS group with sham group, conducted a meta-analysis of all RCTs. Five studies, consisting of 313 migraine patients, were identified. Single-pulse transcranial magnetic stimulation is effective for the acute treatment of migraine with aura after the first attack (p = 0.02). And, the efficacy of TMS on chronic migraine was not significant (OR 2.93; 95% CI 0.71-12.15; p = 0.14). TMS is effective for migraine based on the studies included in the article.

  17. Electron spin resonance of nitrogen-vacancy centers in optically trapped nanodiamonds

    PubMed Central

    Horowitz, Viva R.; Alemán, Benjamín J.; Christle, David J.; Cleland, Andrew N.; Awschalom, David D.

    2012-01-01

    Using an optical tweezers apparatus, we demonstrate three-dimensional control of nanodiamonds in solution with simultaneous readout of ground-state electron-spin resonance (ESR) transitions in an ensemble of diamond nitrogen-vacancy color centers. Despite the motion and random orientation of nitrogen-vacancy centers suspended in the optical trap, we observe distinct peaks in the measured ESR spectra qualitatively similar to the same measurement in bulk. Accounting for the random dynamics, we model the ESR spectra observed in an externally applied magnetic field to enable dc magnetometry in solution. We estimate the dc magnetic field sensitivity based on variations in ESR line shapes to be approximately . This technique may provide a pathway for spin-based magnetic, electric, and thermal sensing in fluidic environments and biophysical systems inaccessible to existing scanning probe techniques. PMID:22869706

  18. Natural remanent magnetization acquisition in bioturbated sediment: General theory and implications for relative paleointensity reconstructions

    NASA Astrophysics Data System (ADS)

    Egli, R.; Zhao, X.

    2015-04-01

    We present a general theory for the acquisition of natural remanent magnetizations (NRM) in sediment under the influence of (a) magnetic torques, (b) randomizing torques, and (c) torques resulting from interaction forces. Dynamic equilibrium between (a) and (b) in the water column and at the sediment-water interface generates a detrital remanent magnetization (DRM), while much stronger randomizing torques may be provided by bioturbation inside the mixed layer. These generate a so-called mixed remanent magnetization (MRM), which is stabilized by mechanical interaction forces. During the time required to cross the surface mixed layer, DRM is lost and MRM is acquired at a rate that depends on bioturbation intensity. Both processes are governed by a MRM lock-in function. The final NRM intensity is controlled mainly by a single parameter γ that is defined as the product of rotational diffusion and mixed-layer thickness, divided by sedimentation rate. This parameter defines three regimes: (1) slow mixing (γ < 0.2) leading to DRM preservation and insignificant MRM acquisition, (2) fast mixing (γ > 10) with MRM acquisition and full DRM randomization, and (3) intermediate mixing. Because the acquisition efficiency of DRM is larger than that of MRM, NRM intensity is particularly sensitive to γ in case of mixed regimes, generating variable NRM acquisition efficiencies. This model explains (1) lock-in delays that can be matched with empirical reconstructions from paleomagnetic records, (2) the existence of small lock-in depths that lead to DRM preservation, (3) specific NRM acquisition efficiencies of magnetofossil-rich sediments, and (4) some relative paleointensity artifacts.

  19. Spectrum of walk matrix for Koch network and its application

    NASA Astrophysics Data System (ADS)

    Xie, Pinchen; Lin, Yuan; Zhang, Zhongzhi

    2015-06-01

    Various structural and dynamical properties of a network are encoded in the eigenvalues of walk matrix describing random walks on the network. In this paper, we study the spectra of walk matrix of the Koch network, which displays the prominent scale-free and small-world features. Utilizing the particular architecture of the network, we obtain all the eigenvalues and their corresponding multiplicities. Based on the link between the eigenvalues of walk matrix and random target access time defined as the expected time for a walker going from an arbitrary node to another one selected randomly according to the steady-state distribution, we then derive an explicit solution to the random target access time for random walks on the Koch network. Finally, we corroborate our computation for the eigenvalues by enumerating spanning trees in the Koch network, using the connection governing eigenvalues and spanning trees, where a spanning tree of a network is a subgraph of the network, that is, a tree containing all the nodes.

  20. Expanding Your Laboratory by Accessing Collaboratory Resources

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Hoyt, David W.; Burton, Sarah D.; Peterson, Michael R.

    2004-03-01

    The Environmental Molecular Sciences Laboratory (EMSL) in Richland, Washington, is the home of a research facility setup by the United States Department of Energy (DOE). The facility is atypical because it houses over 100 cutting-edge research systems for the use of researchers all over the United States and the world. Access to the lab is requested through a peer-review proposal process and the scientists who use the facility are generally referred to as ‘users’. There are six main research facilities housed in EMSL, all of which host visiting researchers. Several of these facilities also participate in the EMSL Collaboratory, amore » remote access capability supported by EMSL operations funds. Of these, the High-Field Magnetic Resonance Facility (HFMRF) and Molecular Science Computing Facility (MSCF) have a significant number of their users performing remote work. The HFMRF in EMSL currently houses 12 NMR spectrometers that range in magnet field strength from 7.05T to 21.1T. Staff associated with the NMR facility offers scientific expertise in the areas of structural biology, solid-state materials/catalyst characterization, and magnetic resonance imaging (MRI) techniques. The way in which the HFMRF operates, with a high level of dedication to remote operation across the full suite of High-Field NMR spectrometers, has earned it the name “Virtual NMR Facility”. This review will focus on the operational aspects of remote research done in the High-Field Magnetic Resonance Facility and the computer tools that make remote experiments possible.« less

  1. Rural providers' access to online resources: a randomized controlled trial

    PubMed Central

    Hall, Laura J.; McElfresh, Karen R.; Warner, Teddy D.; Stromberg, Tiffany L.; Trost, Jaren; Jelinek, Devin A.

    2016-01-01

    Objective The research determined the usage and satisfaction levels with one of two point-of-care (PoC) resources among health care providers in a rural state. Methods In this randomized controlled trial, twenty-eight health care providers in rural areas were stratified by occupation and region, then randomized into either the DynaMed or the AccessMedicine study arm. Study participants were physicians, physician assistants, and nurses. A pre- and post-study survey measured participants' attitudes toward different information resources and their information-seeking activities. Medical student investigators provided training and technical support for participants. Data analyses consisted of analysis of variance (ANOVA), paired t tests, and Cohen's d statistic to compare pre- and post-study effects sizes. Results Participants in both the DynaMed and the AccessMedicine arms of the study reported increased satisfaction with their respective PoC resource, as expected. Participants in both arms also reported that they saved time in finding needed information. At baseline, both arms reported too little information available, which increased to “about right amounts of information” at the completion of the study. DynaMed users reported a Cohen's d increase of +1.50 compared to AccessMedicine users' reported use of 0.82. DynaMed users reported d2 satisfaction increases of 9.48 versus AccessMedicine satisfaction increases of 0.59 using a Cohen's d. Conclusion Participants in the DynaMed arm of the study used this clinically oriented PoC more heavily than the users of the textbook-based AccessMedicine. In terms of user satisfaction, DynaMed users reported higher levels of satisfaction than the users of AccessMedicine. PMID:26807050

  2. Transcranial Magnetic Stimulation for Obsessive-Compulsive Disorder: An Updated Systematic Review and Meta-analysis.

    PubMed

    Trevizol, Alisson Paulino; Shiozawa, Pedro; Cook, Ian A; Sato, Isa Albuquerque; Kaku, Caio Barbosa; Guimarães, Fernanda Bs; Sachdev, Perminder; Sarkhel, Sujit; Cordeiro, Quirino

    2016-12-01

    Transcranial magnetic stimulation (TMS) is a promising noninvasive brain stimulation intervention. Transcranial magnetic stimulation has been proposed for obsessive-compulsive disorder (OCD) with auspicious results. To assess the efficacy of TMS for OCD in randomized clinical trials (RCTs). Systematic review using MEDLINE and EMBASE from the first RCT available until March 11, 2016. The main outcome was the Hedges g for continuous scores for Yale-Brown Obsessive Compulsive Scale in a random-effects model. Heterogeneity was evaluated with the I and the χ test. Publication bias was evaluated using the Begg funnel plot. Metaregression was performed using the random-effects model modified by Knapp and Hartung. We included 15 RCTs (n = 483), most had small-to-modest sample sizes. Comparing active versus sham TMS, active stimulation was significantly superior for OCD symptoms (Hedges g = 0.45; 95% confidence interval, 0.2-0.71). The funnel plot showed that the risk of publication bias was low and between-study heterogeneity was low (I = 43%, P = 0.039 for the χ test). Metaregression showed no particular influence of any variable on the results. Transcranial magnetic stimulation active was superior to sham stimulation for the amelioration of OCD symptoms. Trials had moderate heterogeneity results, despite different protocols of stimulation used. Further RCTs with larger sample sizes are fundamentally needed to clarify the precise impact of TMS in OCD symptoms.

  3. High spatial resolution compressed sensing (HSPARSE) functional MRI.

    PubMed

    Fang, Zhongnan; Van Le, Nguyen; Choy, ManKin; Lee, Jin Hyung

    2016-08-01

    To propose a novel compressed sensing (CS) high spatial resolution functional MRI (fMRI) method and demonstrate the advantages and limitations of using CS for high spatial resolution fMRI. A randomly undersampled variable density spiral trajectory enabling an acceleration factor of 5.3 was designed with a balanced steady state free precession sequence to achieve high spatial resolution data acquisition. A modified k-t SPARSE method was then implemented and applied with a strategy to optimize regularization parameters for consistent, high quality CS reconstruction. The proposed method improves spatial resolution by six-fold with 12 to 47% contrast-to-noise ratio (CNR), 33 to 117% F-value improvement and maintains the same temporal resolution. It also achieves high sensitivity of 69 to 99% compared the original ground-truth, small false positive rate of less than 0.05 and low hemodynamic response function distortion across a wide range of CNRs. The proposed method is robust to physiological noise and enables detection of layer-specific activities in vivo, which cannot be resolved using the highest spatial resolution Nyquist acquisition. The proposed method enables high spatial resolution fMRI that can resolve layer-specific brain activity and demonstrates the significant improvement that CS can bring to high spatial resolution fMRI. Magn Reson Med 76:440-455, 2016. © 2015 The Authors. Magnetic Resonance in Medicine published by Wiley Periodicals, Inc. on behalf of International Society for Magnetic Resonance in Medicine. This is an open access article under the terms of the Creative Commons Attribution-NonCommercial-NoDerivs License, which permits use and distribution in any medium, provided the original work is properly cited, the use is non-commercial and no modifications or adaptations are made. © 2015 The Authors. Magnetic Resonance in Medicine published by Wiley Periodicals, Inc. on behalf of International Society for Magnetic Resonance in Medicine.

  4. A novel 3D Cartesian random sampling strategy for Compressive Sensing Magnetic Resonance Imaging.

    PubMed

    Valvano, Giuseppe; Martini, Nicola; Santarelli, Maria Filomena; Chiappino, Dante; Landini, Luigi

    2015-01-01

    In this work we propose a novel acquisition strategy for accelerated 3D Compressive Sensing Magnetic Resonance Imaging (CS-MRI). This strategy is based on a 3D cartesian sampling with random switching of the frequency encoding direction with other K-space directions. Two 3D sampling strategies are presented. In the first strategy, the frequency encoding direction is randomly switched with one of the two phase encoding directions. In the second strategy, the frequency encoding direction is randomly chosen between all the directions of the K-Space. These strategies can lower the coherence of the acquisition, in order to produce reduced aliasing artifacts and to achieve a better image quality after Compressive Sensing (CS) reconstruction. Furthermore, the proposed strategies can reduce the typical smoothing of CS due to the limited sampling of high frequency locations. We demonstrated by means of simulations that the proposed acquisition strategies outperformed the standard Compressive Sensing acquisition. This results in a better quality of the reconstructed images and in a greater achievable acceleration.

  5. Random isotropic one-dimensional XY-model

    NASA Astrophysics Data System (ADS)

    Gonçalves, L. L.; Vieira, A. P.

    1998-01-01

    The 1D isotropic s = ½XY-model ( N sites), with random exchange interaction in a transverse random field is considered. The random variables satisfy bimodal quenched distributions. The solution is obtained by using the Jordan-Wigner fermionization and a canonical transformation, reducing the problem to diagonalizing an N × N matrix, corresponding to a system of N noninteracting fermions. The calculations are performed numerically for N = 1000, and the field-induced magnetization at T = 0 is obtained by averaging the results for the different samples. For the dilute case, in the uniform field limit, the magnetization exhibits various discontinuities, which are the consequence of the existence of disconnected finite clusters distributed along the chain. Also in this limit, for finite exchange constants J A and J B, as the probability of J A varies from one to zero, the saturation field is seen to vary from Γ A to Γ B, where Γ A(Γ B) is the value of the saturation field for the pure case with exchange constant equal to J A(J B) .

  6. Electronic and magnetic properties of bare armchair BC2N nanoribbons

    NASA Astrophysics Data System (ADS)

    Li, Hong; Xiao, Xiang; Tie, Jun; Lu, Jing

    2017-03-01

    We present the electronic and magnetic properties of bare armchair BC2N nanoribbons (ABC2NNRs) in the view of density functional calculations. We consider three types of edge terminations with a width of 0.75 2.10 nm. All the investigated ribbons exhibit magnetic ground states with the magnetic moments mainly located on the edge C atoms. Room temperature accessible magnetic stabilities are obtained for ABC2NNRs with NC-NC and NC-BC edge alignments. We find the ABC2NNRs have various electronic structures, where half-metal, metal, and semiconductor are all acquired depend on the edge alignment and magnetic coupling state. The results show the ABC2NNRs can be a promising candidate material in nanoelectronics and nanospintronics.

  7. Best practices in evaluation of the magnetocaloric effect from bulk magnetization measurements

    DOE PAGES

    Neves Bez, H.; Yibole, H.; Pathak, A.; ...

    2018-07-15

    Conventional magnetometry is irreplaceable in evaluating bulk magnetization of materials over broad temperature and field ranges. The technique is also effective in quantifying hysteresis that may be associated with magnetic and structural phase transitions that occur during the magnetizing/demagnetizing cycling, and the derived magnetic field-induced isothermal entropy change – one of the most important properties in the field of magnetocalorics. Both systematic and random errors present during the measurements of magnetization, however, may lead to erroneous conclusions. Using two well-known materials – elemental Gd and intermetallic Gd 5Si 2Ge 2 as examples, we consider best practices in performing reliable andmore » rapid magnetization measurements for proper characterization of magnetocaloric properties.« less

  8. Best practices in evaluation of the magnetocaloric effect from bulk magnetization measurements

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Neves Bez, H.; Yibole, H.; Pathak, A.

    Conventional magnetometry is irreplaceable in evaluating bulk magnetization of materials over broad temperature and field ranges. The technique is also effective in quantifying hysteresis that may be associated with magnetic and structural phase transitions that occur during the magnetizing/demagnetizing cycling, and the derived magnetic field-induced isothermal entropy change – one of the most important properties in the field of magnetocalorics. Both systematic and random errors present during the measurements of magnetization, however, may lead to erroneous conclusions. Using two well-known materials – elemental Gd and intermetallic Gd 5Si 2Ge 2 as examples, we consider best practices in performing reliable andmore » rapid magnetization measurements for proper characterization of magnetocaloric properties.« less

  9. Specific loss power in superparamagnetic hyperthermia: nanofluid versus composite

    NASA Astrophysics Data System (ADS)

    Osaci, M.; Cacciola, M.

    2017-01-01

    Currently, the magnetic hyperthermia induced by nanoparticles is of great interest in biomedical applications. In the literature, we can find a lot of models for magnetic hyperthermia, but many of them do not give importance to a significant detail, such as the geometry of nanoparticle positions in the system. Usually, a nanofluid is treated by considering random positions of the nanoparticles, geometry that is actually characteristic to the composite nanoparticles. To assess the error which is frequently made, in this paper we propose a comparative analysis between the specific loss power (SLP) in case of a nanofluid and the SLP in case of a composite with magnetic nanoparticles. We are going to use a superparamagnetic hyperthermia model based on the improved model for calculating the Néel relaxation time in a magnetic field oblique to the nanoparticle magnetic anisotropy axes, and on the improved theoretical model LRT (linear response theory) for SLP. To generate the nanoparticle geometry in the system, we are going to apply a Monte Carlo method to a nanofluid, by minimising the interaction potentials in liquid medium and, for a composite environment, a method for generating random positions of the nanoparticles in a given volume.

  10. Self-Organization by Stochastic Reconnection: The Mechanism Underlying CMEs/Flares

    NASA Astrophysics Data System (ADS)

    Antiochos, S. K.; Knizhnik, K. J.; DeVore, C. R.

    2017-12-01

    The largest explosions in the solar system are the giant CMEs/flares that produce the most dangerous space weather at Earth, yet may also have been essential for the origin of life. The root cause of CMEs/flares is that the lowest-lying magnetic field lines in the Sun's corona undergo the continual buildup of stress and free energy that can be released only through explosive ejection. We perform the first MHD simulations of a coronal-photospheric magnetic system that is driven by random photospheric convective flows and has a realistic geometry for the coronal field. Furthermore, our simulations accurately preserve the key constraint of magnetic helicity. We find that even though small-scale stress is injected randomly throughout the corona, the net result of "stochastic" coronal reconnection is a coherent stretching of the lowest-lying field lines. This highly counter-intuitive demonstration of self-organization - magnetic stress builds up locally rather than spreading out to a minimum energy state - is the fundamental mechanism responsible for the Sun's magnetic explosions and is likely to be a mechanism that is ubiquitous throughout space and laboratory plasmas. This work was supported in part by the NASA LWS and SR Programs.

  11. The Incremental Validity of the MMPI-2: When Does Therapist Access Not Enhance Treatment Outcome?

    ERIC Educational Resources Information Center

    Lima, Elizabeth N.; Stanley, Sheila; Kaboski, Beth; Reitzel, Lorraine R.; Richey, Anthony; Castro, Yezzennya; Williams, Foluso M.; Tannenbaum, Kendra R.; Stellrecht, Nadia E.; Jakobsons, Lara J.; Wingate, LaRicka R.; Joiner, Thomas E.

    2005-01-01

    The present study examined whether therapist access to the Minnesota Multiphasic Personality Inventory (MMPI-2) predicted favorable treatment outcome, above and beyond other assessment measures. A manipulated assessment design was used, in which patients were randomly assigned either to a group in which therapists had access to their MMPI-2 data…

  12. Program Retrieval/Dissemination: A Solid State Random Access System.

    ERIC Educational Resources Information Center

    Weeks, Walter O., Jr.

    The trend toward greater flexibility in educational methods has led to a need for better and more rapid access to a variety of aural and audiovisual resource materials. This in turn has demanded the development of a flexible, reliable system of hardware designed to aid existing distribution methods in providing such access. The system must be…

  13. 77 FR 25994 - Notice of Proposed Information Collection Requests; Institute of Education Sciences; Pell Grant...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-05-02

    ... will have expanded access to Pell grants; or (2) a control group, which will not have access. Within both substudies, the treatment group will be very similar to the control at the time of random... between treatment and control group members can then be attributed to Pell grant access. The first...

  14. Effects of magnetic stimulation on urodynamic stress incontinence refractory to pelvic floor muscle training in a randomized sham-controlled study.

    PubMed

    Yamanishi, Tomonori; Suzuki, Tsuneki; Sato, Ryo; Kaga, Kanya; Kaga, Mayuko; Fuse, Miki

    2017-09-29

    The aim of the present study was to evaluate the effect of magnetic stimulation on urodynamic stress incontinence refractory to pelvic floor muscle training in a randomized sham-controlled study. Female patients with urodynamic stress incontinence who had not been cured by pelvic floor muscle training were randomly assigned at a ratio of 2 : 1 to either active treatment or sham treatment for 10 weeks. The randomization was made using magnetic cards for individuals indicating active or sham stimulation. The primary endpoint was changes in the number of incontinence episodes/week, with secondary endpoints of the degree of incontinence (in g/day; determined using the pad test), the total score on the International Consultation on Incontinence Questionnaire - Short Form (ICIQ-SF), the ICIQ quality of life (QOL) score, and the abdominal leak point pressure (ALPP) on urodynamic study. Although 39 patients were enrolled in the study, 9 dropped out, leaving a total patients for analysis (18 in the active treatment group, 12 in the sham treatment group). The number of incontinence episodes/week, the degree of incontinence, total ICIQ-SF score, ICIQ-QOL score, and ALPP were significantly improved after active treatment compared with baseline (all P < .05), but did not change significantly after sham treatment. There was a significant intergroup difference with regard to changes from baseline in the ICIQ-SF and ALPP in favor of the active treatment group (P < .05). There were no significant differences in any other parameters between the 2 groups. Treatment-related adverse events were not found in both groups. Magnetic stimulation was effective in treating urodynamic stress incontinence. © 2017 John Wiley & Sons Australia, Ltd.

  15. Neural Response After a Single ECT Session During Retrieval of Emotional Self-Referent Words in Depression: A Randomized, Sham-Controlled fMRI Study.

    PubMed

    Miskowiak, Kamilla W; Macoveanu, Julian; Jørgensen, Martin B; Støttrup, Mette M; Ott, Caroline V; Jensen, Hans M; Jørgensen, Anders; Harmer, J; Paulson, Olaf B; Kessing, Lars V; Siebner, Hartwig R

    2018-03-01

    Negative neurocognitive bias is a core feature of depression that is reversed by antidepressant drug treatment. However, it is unclear whether modulation of neurocognitive bias is a common mechanism of distinct biological treatments. This randomized controlled functional magnetic resonance imaging study explored the effects of a single electroconvulsive therapy session on self-referent emotional processing. Twenty-nine patients with treatment-resistant major depressive disorder were randomized to one active or sham electroconvulsive therapy session at the beginning of their electroconvulsive therapy course in a double-blind, between-groups design. The following day, patients were given a self-referential emotional word categorization test and a free recall test. This was followed by an incidental word recognition task during whole-brain functional magnetic resonance imaging at 3T. Mood was assessed at baseline, on the functional magnetic resonance imaging day, and after 6 electroconvulsive therapy sessions. Data were complete and analyzed for 25 patients (electroconvulsive therapy: n = 14, sham: n = 11). The functional magnetic resonance imaging data were analyzed using the FMRIB Software Library randomize algorithm, and the Threshold-Free Cluster Enhancement method was used to identify significant clusters (corrected at P < .05). A single electroconvulsive therapy session had no effect on hippocampal activity during retrieval of emotional words. However, electroconvulsive therapy reduced the retrieval-specific neural response for positive words in the left frontopolar cortex. This effect occurred in the absence of differences between groups in behavioral performance or mood symptoms. The observed effect of electroconvulsive therapy on prefrontal response may reflect early facilitation of memory for positive self-referent information, which could contribute to improvements in depressive symptoms including feelings of self-worth with repeated treatments.

  16. Supernova-regulated ISM. V. Space and Time Correlations

    NASA Astrophysics Data System (ADS)

    Hollins, J. F.; Sarson, G. R.; Shukurov, A.; Fletcher, A.; Gent, F. A.

    2017-11-01

    We apply correlation analysis to random fields in numerical simulations of the supernova-driven interstellar medium (ISM) with the magnetic field produced by dynamo action. We solve the magnetohydrodynamic (MHD) equations in a shearing Cartesian box representing a local region of the ISM, subject to thermal and kinetic energy injection by supernova explosions, and parameterized, optically thin radiative cooling. We consider the cold, warm, and hot phases of the ISM separately; the analysis mostly considers the warm gas, which occupies the bulk of the domain. Various physical variables have different correlation lengths in the warm phase: 40,50, and 60 {pc} for the random magnetic field, density, and velocity, respectively, in the midplane. The correlation time of the random velocity is comparable to the eddy turnover time, about {10}7 {year}, although it may be shorter in regions with a higher star formation rate. The random magnetic field is anisotropic, with the standard deviations of its components {b}x/{b}y/{b}z having approximate ratios 0.5/0.6/0.6 in the midplane. The anisotropy is attributed to the global velocity shear from galactic differential rotation and locally inhomogeneous outflow to the galactic halo. The correlation length of Faraday depth along the z axis, 120 {pc}, is greater than for electron density, 60{--}90 {pc}, and the vertical magnetic field, 60 {pc}. Such comparisons may be sensitive to the orientation of the line of sight. Uncertainties of the structure functions of synchrotron intensity rapidly increase with the scale. This feature is hidden in a power spectrum analysis, which can undermine the usefulness of power spectra for detailed studies of interstellar turbulence.

  17. Magnetic field-temperature phase diagram of multiferroic [(CH3)2NH2] Mn (HCOO) 3

    NASA Astrophysics Data System (ADS)

    Clune, A. J.; Hughey, K. D.; Lee, C.; Abhyankar, N.; Ding, X.; Dalal, N. S.; Whangbo, M.-H.; Singleton, J.; Musfeldt, J. L.

    2017-09-01

    We combined pulsed field magnetization and first-principles spin-density calculations to reveal the magnetic field-temperature phase diagram and spin state character in multiferroic [(CH3)2NH2] Mn (HCOO) 3 . Despite similarities with the rare earth manganites, the phase diagram is analogous to other Mn-based quantum magnets with a 0.31 T spin flop, a 15.3 T transition to the fully polarized state, and short-range correlations that persist above the ordering temperature. The experimentally accessible saturation field opens the door to exploration of the high-field phase.

  18. Combinatorial investigation of rare-earth free permanent magnets

    NASA Astrophysics Data System (ADS)

    Fackler, Sean Wu

    The combinatorial high throughput method allows one to rapidly study a large number of samples with systematically changing parameters. We apply this method to study Fe-Co-V alloys as alternatives to rare-earth permanent magnets. Rare-earth permanent magnets derive their unmatched magnetic properties from the hybridization of Fe and Co with the f-orbitals of rare-earth elements, which have strong spin-orbit coupling. It is predicted that Fe and Co may also have strong hybridization with 4d and 5d refractory transition metals with strong spin-orbit coupling. Refractory transition metals like V also have the desirable property of high temperature stability, which is important for permanent magnet applications in traction motors. In this work, we focus on the role of crystal structure, composition, and secondary phases in the origin of competitive permanent magnetic properties of a particular Fe-Co-V alloy. Fe38Co52V10, compositions are known as Vicalloys. Fe-CoV composition spreads were sputtered onto three-inch silicon wafers and patterned into discrete sample pads forming a combinatorial library. We employed highthroughput screening methods using synchrotron X-rays, wavelength dispersive spectroscopy, and magneto-optical Kerr effect (MOKE) to rapidly screen crystal structure, composition, and magnetic properties, respectively. We found that in-plane magnetic coercive fields of our Vicalloy thin films agree with known bulk values (300 G), but found a remarkable eight times increase of the out-of-plane coercive fields (˜2,500 G). To explain this, we measured the switching fields between in-plane and out-of-plane thin film directions which revealed that the Kondorsky model of 180° domain wall reversal was responsible for Vicalloy's enhanced out-of-plane coercive field and possibly its permanent magnetic properties. The Kondorsky model suggests that domain-wall pinning is the origin of Vicalloy's permanent magnetic properties, in contrast to strain, shape, or crystalline anisotropy mechanisms suggested in the literature. We also studied the thickness dependence of an Fe70Co30- V thin film library to consider the unique effects of our thin film libraries which are not found in bulk samples. We present results of data mining of synchrotron X-ray diffraction data using non-negative matrix factorization (NMF). NMF can automatically identify pure crystal phases that make up an unknown phase mixture. We found a strong correlation between magnetic properties and crystal phase quantity using this valuable visualization. In addition to the combinatorial study, this dissertation includes a study of strain controlled properties of magnetic thin films for future applications in random access memories. We investigated the local coupling between dense magnetic stripe domains in transcritical Permalloy (tPy) thin films and ferroelectric domains of BaTiO3 single crystals in a tPy/BaTiO3 heterostructure. Two distinct changes in the magnetic stripe domains of tPy were observed from the magnetic force microscopy images after cooling the heterostructure from above the ferroelectric Curie temperature of BaTiO3 (120°C) to room temperature. First, an abrupt break in the magnetic stripe domain direction was found at the ferroelectric a-c-domain boundaries due to an induced change in in-plane magnetic anisotropy. Second, the magnetic stripe domain period increased when coupled to a ferroelectric a-domain due to a change in out-of-plane magnetic anisotropy. Micromagnetic simulations reveal that local magnetic anisotropy energy from inverse magnetostriction is conserved between in-plane and out-of-plane components.

  19. Random crystal field effect on the magnetic and hysteresis behaviors of a spin-1 cylindrical nanowire

    NASA Astrophysics Data System (ADS)

    Zaim, N.; Zaim, A.; Kerouad, M.

    2017-02-01

    In this work, the magnetic behavior of the cylindrical nanowire, consisting of a ferromagnetic core of spin-1 atoms surrounded by a ferromagnetic shell of spin-1 atoms is studied in the presence of a random crystal field interaction. Based on Metropolis algorithm, the Monte Carlo simulation has been used to investigate the effects of the concentration of the random crystal field p, the crystal field D and the shell exchange interaction Js on the phase diagrams and the hysteresis behavior of the system. Some characteristic behaviors have been found, such as the first and second-order phase transitions joined by tricritical point for appropriate values of the system parameters, triple and isolated critical points can be also found. Depending on the Hamiltonian parameters, single, double and para hysteresis regions are explicitly determined.

  20. Electrical Switching of Perovskite Thin-Film Resistors

    NASA Technical Reports Server (NTRS)

    Liu, Shangqing; Wu, Juan; Ignatiev, Alex

    2010-01-01

    Electronic devices that exploit electrical switching of physical properties of thin films of perovskite materials (especially colossal magnetoresistive materials) have been invented. Unlike some related prior devices, these devices function at room temperature and do not depend on externally applied magnetic fields. Devices of this type can be designed to function as sensors (exhibiting varying electrical resistance in response to varying temperature, magnetic field, electric field, and/or mechanical pressure) and as elements of electronic memories. The underlying principle is that the application of one or more short electrical pulse(s) can induce a reversible, irreversible, or partly reversible change in the electrical, thermal, mechanical, and magnetic properties of a thin perovskite film. The energy in the pulse must be large enough to induce the desired change but not so large as to destroy the film. Depending on the requirements of a specific application, the pulse(s) can have any of a large variety of waveforms (e.g., square, triangular, or sine) and be of positive, negative, or alternating polarity. In some applications, it could be necessary to use multiple pulses to induce successive incremental physical changes. In one class of applications, electrical pulses of suitable shapes, sizes, and polarities are applied to vary the detection sensitivities of sensors. Another class of applications arises in electronic circuits in which certain resistance values are required to be variable: Incorporating the affected resistors into devices of the present type makes it possible to control their resistances electrically over wide ranges, and the lifetimes of electrically variable resistors exceed those of conventional mechanically variable resistors. Another and potentially the most important class of applications is that of resistance-based nonvolatile-memory devices, such as a resistance random access memory (RRAM) described in the immediately following article, Electrically Variable Resistive Memory Devices (MFS-32511-1).

  1. Magnetic Minerals in Soils and Paleosols as Recorders of Paleoclimate

    NASA Astrophysics Data System (ADS)

    Maxbauer, Daniel P.

    It is a fundamental challenge for geologists to create quantitative estimates of rainfall and temperature in past climates. Yet, records of past climates are integral for understanding the complexities of earth system dynamics. The research presented in this dissertation begins to establish a framework for reconstructing paleoclimates using the magnetic properties of fossilized soils. Magnetic minerals are ubiquitous in soils, and their composition, grain size, and concentration is often directly related to the ambient climatic conditions that were present during soil formation. Using rock magnetic methods, it is possible to sensitively characterize the magnetic mineral assemblages in natural materials - including soils and paleosols. The fundamentals of rock magnetism and many of the common methods used in rock magnetic applications are presented in chapter 2 and chapter 3, respectively. Chapter 4 reviews the physical, chemical, and biological factors that affect magnetic mineral assemblages in soils, the magnetic methods we use to characterize them, and the known relationships between magnetic minerals in soils and climate. A critical component to developing replicable tools for reconstructing paleoclimate is developing analytical and statistical tools that are accessible to the greater community. Chapter 5 introduces a new model, MAX UnMix, that was developed as an open-source, online tool for rock magnetic data processing that is designed to be user-friendly and accessible. Two case studies, on both fossil (Chapter 7) and modern (Chapter 6) soils, are presented and discuss many issues related to applying magnetic paleoprecipitation proxies in deep time. Chapter 7 discusses difficulties in disentangling the effects of pedogenesis, diagenesis, and recent surficial weathering in Paleocene-Eocene ( 56-55 Ma) paleosols. Chapter 6 explores the relative influence of soil forming factors (vegetation vs. climate) on controlling the pedogenic formation of magnetic minerals in soils developing across the forest-to-prairie ecotone in NW Minnesota. The body of research presented in this dissertation provides many challenges to future workers, while at the same time highlighting that rock magnetism should be a useful tool for researchers interested in deep time paleoclimates moving forward.

  2. Effects of Home Access to Active Videogames on Child Self-Esteem, Enjoyment of Physical Activity, and Anxiety Related to Electronic Games: Results from a Randomized Controlled Trial.

    PubMed

    Abbott, Rebecca A; Smith, Anne J; Howie, Erin K; Pollock, Clare; Straker, Leon

    2014-08-01

    Active-input videogames could provide a useful conduit for increasing physical activity by improving a child's self-confidence, physical activity enjoyment, and reducing anxiety. Therefore this study evaluated the impact of (a) the removal of home access to traditional electronic games or (b) their replacement with active-input videogames, on child self-perception, enjoyment of physical activity, and electronic game use anxiety. This was a crossover, randomized controlled trial, conducted over a 6-month period in participants' family homes in metropolitan Perth, Australia, from 2007 to 2010. Children 10-12 years old were recruited through school and community media. Of 210 children who were eligible, 74 met inclusion criteria, and 8 withdrew, leaving 66 children (33 girls) for analysis. A counterbalanced randomized order of three conditions sustained for 8 weeks each: No home access to electronic games, home access to traditional electronic games, and home access to active-input electronic games. Perception of self-esteem (Harter's Self Perception Profile for Children), enjoyment of physical activity (Physical Activity Enjoyment Scale questionnaire), and anxiety toward electronic game use (modified Loyd and Gressard Computer Anxiety Subscale) were assessed. Compared with home access to traditional electronic games, neither removal of all electronic games nor replacement with active-input games resulted in any significant change to child self-esteem, enjoyment of physical activity, or anxiety related to electronic games. Although active-input videogames have been shown to be enjoyable in the short term, their ability to impact on psychological outcomes is yet to be established.

  3. Metal spintronics: Tunneling spectroscopy in junctions with magnetic and superconducting electrodes

    NASA Astrophysics Data System (ADS)

    Yang, Hyunsoo

    Recent advances in generating, manipulating and detecting spin-polarized electrons and their electrical current make possible entirely new classes of spin-based sensor, logic and storage devices. An important such device is the magnetic tunnel junction (MTJ) which has been under intensive study in recent years: important applications include nonvolatile memory cells for high performance magnetic random access memory (MRAMs), and magnetic field sensors for high density hard disk drive read heads. Many aspects of the tunneling magnetoresistance (TMR) phenomenon are poorly understood although it is clear that the fundamental origin of TMR is the spin-polarization of the tunneling current. Thus, the measurement of the magnitude and sign of the tunneling spin polarization (TSP) is very important to help the further understanding of TMR. Recently, an extremely high TMR value, of up to 350% at room temperature, has been reported in practical MTJ devices. These MTJs are fabricated with highly oriented crystalline MgO(100) tunnel barriers by straightforward magnetron sputter deposition at room temperature. In parallel with this observation, we report extremely high TSP values exceeding 90% from CoFe/MgO tunnel spin injectors. These TSP values rival the highest polarization values previously reported using exotic half-metallic oxide ferromagnets. The spin polarization of electrons extracted from ferromagnetic films can be probed by a variety of techniques. Amongst these techniques, STS is perhaps the most relevant with respect to TMR but until now all measurements have been made with Al superconducting films which have low superconducting transition temperatures (Tc) so that the measurements must be made at temperatures below 400mK. We demonstrate the use of superconducting electrodes formed from NbN which has a much higher Tc (˜16K) than Al. The use of NbN allows measurements of TSP at higher temperatures above 1K. We have observed the phenomenon of Kondo-assisted tunneling in planar magnetic tunnel junctions. We demonstrate not only an increased conductance at low bias but also show that the tunneling magnetoresistance is quenched in the Kondo regime. The Kondo effect may be a useful means of detecting and possibly manipulating the spins of individual electrons in nanodots.

  4. Theorem: A Static Magnetic N-pole Becomes an Oscillating Electric N-pole in a Cosmic Axion Field

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Hill, Christopher T.

    We show for the classical Maxwell equations, including the axion electromagnetic anomaly source term, that a cosmic axion field induces an oscillating electric N-moment for any static magnetic N-moment. This is a straightforward result, accessible to anyone who has taken a first year graduate course in electrodynamics.

  5. Tuning resistance states by thickness control in an electroforming-free nanometallic complementary resistance random access memory

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Yang, Xiang; Lu, Yang; Lee, Jongho

    2016-01-04

    Tuning low resistance state is crucial for resistance random access memory (RRAM) that aims to achieve optimal read margin and design flexibility. By back-to-back stacking two nanometallic bipolar RRAMs with different thickness into a complementary structure, we have found that its low resistance can be reliably tuned over several orders of magnitude. Such high tunability originates from the exponential thickness dependence of the high resistance state of nanometallic RRAM, in which electron wave localization in a random network gives rise to the unique scaling behavior. The complementary nanometallic RRAM provides electroforming-free, multi-resistance-state, sub-100 ns switching capability with advantageous characteristics formore » memory arrays.« less

  6. Dual-function magnetic structure for toroidal plasma devices

    DOEpatents

    Brown, Robert L.

    1978-01-01

    This invention relates to a support system wherein the iron core and yoke of the plasma current system of a tokamak plasma containment device is redesigned to support the forces of the magnet coils. The containment rings, which occupy very valuable space around the magnet coils, are utilized to serve as yokes for the core such that the conventional yoke is eliminated. The overall result is an improved aspect ratio, reduction in structure, smaller overall size, and improved access to the plasma ring.

  7. Fingerprints of orbital physics in magnetic resonant inelastic X-ray scattering

    NASA Astrophysics Data System (ADS)

    Marra, Pasquale

    2012-09-01

    Orbital degrees of freedom play a major role in the physics of many strongly correlated transition metal compounds. However, they are still very difficult to access experimentally, in particular by neutron scattering. We propose here how to reveal orbital occupancies of the system ground state by magnetic resonant inelastic x-ray scattering (RIXS). This is possible because, unlike in neutron scattering, the intensity of the magnetic excitations in RIXS depends essentially on the symmetry of the orbitals where the spins are in.

  8. Forces between permanent magnets: experiments and model

    NASA Astrophysics Data System (ADS)

    González, Manuel I.

    2017-03-01

    This work describes a very simple, low-cost experimental setup designed for measuring the force between permanent magnets. The experiment consists of placing one of the magnets on a balance, attaching the other magnet to a vertical height gauge, aligning carefully both magnets and measuring the load on the balance as a function of the gauge reading. A theoretical model is proposed to compute the force, assuming uniform magnetisation and based on laws and techniques accessible to undergraduate students. A comparison between the model and the experimental results is made, and good agreement is found at all distances investigated. In particular, it is also found that the force behaves as r -4 at large distances, as expected.

  9. Virtual Humans for Implantable Device Safety Assessment in MRI: Mitigating Magnetic Resonance Imaging Hazards for Implanted Medical Devices.

    PubMed

    Brown, James E; Qiang, Rui; Stadnik, Paul J; Stotts, Larry J; Von Arx, Jeffrey A

    2017-01-01

    Magnetic resonance imaging (MRI) is the preferred modality for soft tissue imaging because of its nonionizing radiation and lack of contrast agent. Due to interactions between the MR system and active implantable medical devices (AIMDs), patients with implants such as pacemakers are generally denied access to MRI, which presents a detriment to that population. It has been estimated that 50-75% of patients with a cardiac device were denied access to MRI scanning and, moreover, that 17% of pacemaker patients need an MRI within 12 months of implantation [1]. In recent years, AIMD manufacturers, such as Biotronik, have assessed the conditional safety of devices in MRI.

  10. Low power consumption resistance random access memory with Pt/InOx/TiN structure

    NASA Astrophysics Data System (ADS)

    Yang, Jyun-Bao; Chang, Ting-Chang; Huang, Jheng-Jie; Chen, Yu-Ting; Tseng, Hsueh-Chih; Chu, Ann-Kuo; Sze, Simon M.; Tsai, Ming-Jinn

    2013-09-01

    In this study, the resistance switching characteristics of a resistive random access memory device with Pt/InOx/TiN structure is investigated. Unstable bipolar switching behavior is observed during the initial switching cycle, which then stabilizes after several switching cycles. Analyses indicate that the current conduction mechanism in the resistance state is dominated by Ohmic conduction. The decrease in electrical conductance can be attributed to the reduction of the cross-sectional area of the conduction path. Furthermore, the device exhibits low operation voltage and power consumption.

  11. Effect of Atomic Layer Depositions (ALD)-Deposited Titanium Oxide (TiO2) Thickness on the Performance of Zr40Cu35Al15Ni10 (ZCAN)/TiO2/Indium (In)-Based Resistive Random Access Memory (RRAM) Structures

    DTIC Science & Technology

    2015-08-01

    metal structures, memristors, resistive random access memory, RRAM, titanium dioxide, Zr40Cu35Al15Ni10, ZCAN, resistive memory, tunnel junction 16...TiO2 thickness ........................6 1 1. Introduction Resistive-switching memory elements based on metal-insulator-metal (MIM) diodes ...have attracted great interest due to their potential as components for simple, inexpensive, and high-density non-volatile storage devices. MIM diodes

  12. Lowering data retention voltage in static random access memory array by post fabrication self-improvement of cell stability by multiple stress application

    NASA Astrophysics Data System (ADS)

    Mizutani, Tomoko; Takeuchi, Kiyoshi; Saraya, Takuya; Kobayashi, Masaharu; Hiramoto, Toshiro

    2018-04-01

    We propose a new version of the post fabrication static random access memory (SRAM) self-improvement technique, which utilizes multiple stress application. It is demonstrated that, using a device matrix array (DMA) test element group (TEG) with intrinsic channel fully depleted (FD) silicon-on-thin-buried-oxide (SOTB) six-transistor (6T) SRAM cells fabricated by the 65 nm technology, the lowering of data retention voltage (DRV) is more effectively achieved than using the previously proposed single stress technique.

  13. General Relativistic Simulations of Magnetized Plasmas Around Merging Supermassive Black Holes

    NASA Technical Reports Server (NTRS)

    Giacomazzo, Bruno; Baker, John G.; Miller, M. Coleman; Reynolds, Christopher S.; van Meter, James R.

    2012-01-01

    Coalescing supermassive black hole binaries are produced by the mergers of galaxies and are the most powerful sources of gravitational waves accessible to space-based gravitational observatories. Some such mergers may occur in the presence of matter and magnetic fields and hence generate an electromagnetic counterpart. In this paper we present the first general relativistic simulations of magnetized plasma around merging supermassive black holes using the general relativistic magnetohydrodynamic code Whisky. By considering different magnetic field strengths, going from non-magnetically dominated to magnetically dominated regimes, we explore how magnetic fields affect the dynamics of the plasma and the possible emission of electromagnetic signals. In particular we observe, total amplification of the magnetic field of approx 2 orders of magnitude which is driven by the accretion onto the binary and that leads to stronger electromagnetic signals than in the force-free regime where such amplifications are not possible.

  14. Effect of magnetic field on seed germination and seedling growth of sunflower

    NASA Astrophysics Data System (ADS)

    Matwijczuk, A.; Kornarzyński, K.; Pietruszewski, S.

    2012-07-01

    The impact of a variable magnetic field, magnetically treated water and a combination of both these factors on the germination of seeds and the final mass at the initial stage of growth sunflower plants was presented. Investigations were carried out in pots filled with sand, tin an air-conditioned plant house with no access to daylight using fluorescent light as illumination. A statistical significance positive impact was achieved for the samples subjected to the interaction of both stimulating factors simultaneously, the magnetic field and the impact of treated water several times on the speed of seed germination and final plant mass. Negative impacts were obtained for the majority of the test cases, for the magnetically treated water, the short duration of activity of the magnetic field and for the connection of the magnetic field and low-flow times.

  15. Cloud-based calculators for fast and reliable access to NOAA's geomagnetic field models

    NASA Astrophysics Data System (ADS)

    Woods, A.; Nair, M. C.; Boneh, N.; Chulliat, A.

    2017-12-01

    While the Global Positioning System (GPS) provides accurate point locations, it does not provide pointing directions. Therefore, the absolute directional information provided by the Earth's magnetic field is of primary importance for navigation and for the pointing of technical devices such as aircrafts, satellites and lately, mobile phones. The major magnetic sources that affect compass-based navigation are the Earth's core, its magnetized crust and the electric currents in the ionosphere and magnetosphere. NOAA/CIRES Geomagnetism (ngdc.noaa.gov/geomag/) group develops and distributes models that describe all these important sources to aid navigation. Our geomagnetic models are used in variety of platforms including airplanes, ships, submarines and smartphones. While the magnetic field from Earth's core can be described in relatively fewer parameters and is suitable for offline computation, the magnetic sources from Earth's crust, ionosphere and magnetosphere require either significant computational resources or real-time capabilities and are not suitable for offline calculation. This is especially important for small navigational devices or embedded systems, where computational resources are limited. Recognizing the need for a fast and reliable access to our geomagnetic field models, we developed cloud-based application program interfaces (APIs) for NOAA's ionospheric and magnetospheric magnetic field models. In this paper we will describe the need for reliable magnetic calculators, the challenges faced in running geomagnetic field models in the cloud in real-time and the feedback from our user community. We discuss lessons learned harvesting and validating the data which powers our cloud services, as well as our strategies for maintaining near real-time service, including load-balancing, real-time monitoring, and instance cloning. We will also briefly talk about the progress we achieved on NOAA's Big Earth Data Initiative (BEDI) funded project to develop API interface to our Enhanced Magnetic Model (EMM).

  16. Implications of p +Pb measurements on the chiral magnetic effect in heavy ion collisions

    NASA Astrophysics Data System (ADS)

    Belmont, R.; Nagle, J. L.

    2017-08-01

    The chiral magnetic effect (CME) is a fundamental prediction of QCD, and various observables have been proposed in heavy ion collisions to access this physics. Recently the CMS Collaboration [V. Khachatryan et al., Phys. Rev. Lett. 118, 122301 (2017), 10.1103/PhysRevLett.118.122301] has reported results from p +Pb collisions at 5.02 TeV on one such observable, the three-point correlator. The results are strikingly similar to those measured at the same particle multiplicity in Pb +Pb collisions, which have been attributed to the CME. This similarity, combined with two key assumptions about the magnetic field in p +Pb collisions, presents a major challenge to the CME picture. These two assumptions as stated in the CMS paper are (i) that the magnetic field in p +Pb collisions is smaller than that in Pb +Pb collisions and (ii) that the magnetic field direction is uncorrelated with the flow angle. We test these two postulates in the Monte Carlo-Glauber framework and find that the magnetic fields are not significantly smaller in central p +Pb collisions; however the magnetic field direction and the flow angle are indeed uncorrelated. The second finding alone gives strong evidence that the three-point correlator signal in Pb +Pb and p +Pb collisions is not an indication of the CME. Similar measurements in d +Au over a range of energies accessible at the BNL Relativistic Heavy Ion Collider would be elucidating. In the same calculational framework, we find that even in Pb +Pb collisions, where the magnetic field direction and the flow angle are correlated, there exist large inhomogeneities that are on the size scale of topological domains. These inhomogeneities need to be incorporated in any detailed CME calculation.

  17. Dispersion relation for electromagnetic propagation in stochastic dielectric and magnetic helical photonic crystals

    NASA Astrophysics Data System (ADS)

    Avendaño, Carlos G.; Reyes, Arturo

    2017-03-01

    We theoretically study the dispersion relation for axially propagating electromagnetic waves throughout a one-dimensional helical structure whose pitch and dielectric and magnetic properties are spatial random functions with specific statistical characteristics. In the system of coordinates rotating with the helix, by using a matrix formalism, we write the set of differential equations that governs the expected value of the electromagnetic field amplitudes and we obtain the corresponding dispersion relation. We show that the dispersion relation depends strongly on the noise intensity introduced in the system and the autocorrelation length. When the autocorrelation length increases at fixed fluctuation and when the fluctuation augments at fixed autocorrelation length, the band gap widens and the attenuation coefficient of electromagnetic waves propagating in the random medium gets larger. By virtue of the degeneracy in the imaginary part of the eigenvalues associated with the propagating modes, the random medium acts as a filter for circularly polarized electromagnetic waves, in which only the propagating backward circularly polarized wave can propagate with no attenuation. Our results are valid for any kind of dielectric and magnetic structures which possess a helical-like symmetry such as cholesteric and chiral smectic-C liquid crystals, structurally chiral materials, and stressed cholesteric elastomers.

  18. Generation of Aptamers from A Primer-Free Randomized ssDNA Library Using Magnetic-Assisted Rapid Aptamer Selection

    NASA Astrophysics Data System (ADS)

    Tsao, Shih-Ming; Lai, Ji-Ching; Horng, Horng-Er; Liu, Tu-Chen; Hong, Chin-Yih

    2017-04-01

    Aptamers are oligonucleotides that can bind to specific target molecules. Most aptamers are generated using random libraries in the standard systematic evolution of ligands by exponential enrichment (SELEX). Each random library contains oligonucleotides with a randomized central region and two fixed primer regions at both ends. The fixed primer regions are necessary for amplifying target-bound sequences by PCR. However, these extra-sequences may cause non-specific bindings, which potentially interfere with good binding for random sequences. The Magnetic-Assisted Rapid Aptamer Selection (MARAS) is a newly developed protocol for generating single-strand DNA aptamers. No repeat selection cycle is required in the protocol. This study proposes and demonstrates a method to isolate aptamers for C-reactive proteins (CRP) from a randomized ssDNA library containing no fixed sequences at 5‧ and 3‧ termini using the MARAS platform. Furthermore, the isolated primer-free aptamer was sequenced and binding affinity for CRP was analyzed. The specificity of the obtained aptamer was validated using blind serum samples. The result was consistent with monoclonal antibody-based nephelometry analysis, which indicated that a primer-free aptamer has high specificity toward targets. MARAS is a feasible platform for efficiently generating primer-free aptamers for clinical diagnoses.

  19. Time-frequency peak filtering for random noise attenuation of magnetic resonance sounding signal

    NASA Astrophysics Data System (ADS)

    Lin, Tingting; Zhang, Yang; Yi, Xiaofeng; Fan, Tiehu; Wan, Ling

    2018-05-01

    When measuring in a geomagnetic field, the method of magnetic resonance sounding (MRS) is often limited because of the notably low signal-to-noise ratio (SNR). Most current studies focus on discarding spiky noise and power-line harmonic noise cancellation. However, the effects of random noise should not be underestimated. The common method for random noise attenuation is stacking, but collecting multiple recordings merely to suppress random noise is time-consuming. Moreover, stacking is insufficient to suppress high-level random noise. Here, we propose the use of time-frequency peak filtering for random noise attenuation, which is performed after the traditional de-spiking and power-line harmonic removal method. By encoding the noisy signal with frequency modulation and estimating the instantaneous frequency using the peak of the time-frequency representation of the encoded signal, the desired MRS signal can be acquired from only one stack. The performance of the proposed method is tested on synthetic envelope signals and field data from different surveys. Good estimations of the signal parameters are obtained at different SNRs. Moreover, an attempt to use the proposed method to handle a single recording provides better results compared to 16 stacks. Our results suggest that the number of stacks can be appropriately reduced to shorten the measurement time and improve the measurement efficiency.

  20. Extracting Information about the Rotator Cuff from Magnetic Resonance Images Using Deterministic and Random Techniques

    PubMed Central

    De Los Ríos, F. A.; Paluszny, M.

    2015-01-01

    We consider some methods to extract information about the rotator cuff based on magnetic resonance images; the study aims to define an alternative method of display that might facilitate the detection of partial tears in the supraspinatus tendon. Specifically, we are going to use families of ellipsoidal triangular patches to cover the humerus head near the affected area. These patches are going to be textured and displayed with the information of the magnetic resonance images using the trilinear interpolation technique. For the generation of points to texture each patch, we propose a new method that guarantees the uniform distribution of its points using a random statistical method. Its computational cost, defined as the average computing time to generate a fixed number of points, is significantly lower as compared with deterministic and other standard statistical techniques. PMID:25650281

  1. Role of random magnetic anisotropy on the valence, magnetocaloric and resistivity properties in a hexagonal Sm2Ni0.87Si2.87 compound

    NASA Astrophysics Data System (ADS)

    Pakhira, Santanu; Kundu, Asish K.; Mazumdar, Chandan; Ranganathan, R.

    2018-05-01

    In this work, we report the effect of random magnetic anisotropy (RMA) on the valence, magnetocaloric and resistivity properties in a glassy intermetallic material Sm2Ni0.87Si2.87. On the basis of detailed studies on the valence band and core level electronic structure, we have established that both the Sm3+ and Sm2+ ions are present in the system, suggesting the compound to be of mixed valence in nature. The significant observation of positive magnetic entropy change in zero-field cooled measurement has been argued due to the presence of RMA that develops due to local electronic environmental variations between the rare-earth ions in the system. The quantum interference effect caused by the elastic electron–electron interaction is responsible for the resistivity upturn at low-temperature for this disordered metallic conductor.

  2. Reconstruction of the static magnetic field of a magnetron

    NASA Astrophysics Data System (ADS)

    Krüger, Dennis; Köhn, Kevin; Gallian, Sara; Brinkmann, Ralf Peter

    2018-06-01

    The simulation of magnetron discharges requires a quantitatively correct mathematical model of the magnetic field structure. This study presents a method to construct such a model on the basis of a spatially restricted set of experimental data and a plausible a priori assumption on the magnetic field configuration. The example in focus is that of a planar circular magnetron. The experimental data are Hall probe measurements of the magnetic flux density in an accessible region above the magnetron plane [P. D. Machura et al., Plasma Sources Sci. Technol. 23, 065043 (2014)]. The a priori assumption reflects the actual design of the device, and it takes the magnetic field emerging from a center magnet of strength m C and vertical position d C and a ring magnet of strength m R , vertical position d R , and radius R. An analytical representation of the assumed field configuration can be formulated in terms of generalized hypergeometric functions. Fitting the ansatz to the experimental data with a least square method results in a fully specified analytical field model that agrees well with the data inside the accessible region and, moreover, is physically plausible in the regions outside of it. The outcome proves superior to the result of an alternative approach which starts from a multimode solution of the vacuum field problem formulated in terms of polar Bessel functions and vertical exponentials. As a first application of the obtained field model, typical electron and ion Larmor radii and the gradient and curvature drift velocities of the electron guiding center are calculated.

  3. Using Motion Planning to Determine the Existence of an Accessible Route in a CAD Environment

    ERIC Educational Resources Information Center

    Pan, Xiaoshan; Han, Charles S.; Law, Kincho H.

    2010-01-01

    We describe an algorithm based on motion-planning techniques to determine the existence of an accessible route through a facility for a wheeled mobility device. The algorithm is based on LaValle's work on rapidly exploring random trees and is enhanced to take into consideration the particularities of the accessible route domain. Specifically, the…

  4. Observed Faraday Effects in Damped Lyα Absorbers and Lyman Limit Systems: The Magnetized Environment of Galactic Building Blocks at Redshift = 2

    NASA Astrophysics Data System (ADS)

    Farnes, J. S.; Rudnick, L.; Gaensler, B. M.; Haverkorn, M.; O'Sullivan, S. P.; Curran, S. J.

    2017-06-01

    Protogalactic environments are typically identified using quasar absorption lines and can manifest as Damped Lyman-alpha Absorbers (DLAs) and Lyman Limit Systems (LLSs). We use radio observations of Faraday effects to test whether these galactic building blocks host a magnetized medium, by combining DLA and LLS detections with 1.4 GHz polarization data from the NRAO VLA Sky Survey (NVSS). We obtain a control, a DLA, and an LLS sample consisting of 114, 19, and 27 lines of sight, respectively. Using a Bayesian framework and weakly informative priors, we are unable to detect either coherent or random magnetic fields in DLAs: the regular coherent fields must be ≤slant 2.8 μG, and the lack of depolarization suggests the weakly magnetized gas in DLAs is non-turbulent and quiescent. However, we find a mild suggestive indication that LLSs have coherent magnetic fields, with a 71.5% probability that LLSs have higher | {RM}| than a control, although this is sensitive to the redshift distribution. We also find a strong indication that LLSs host random magnetic fields, with a 95.5% probability that LLS lines of sight have lower polarized fractions than a control. The regular coherent fields within the LLSs must be ≤slant 2.4 μG, and the magnetized gas must be highly turbulent with a typical turbulent length scale on the order of ≈5-20 pc. Our results are consistent with the standard dynamo paradigm, whereby magnetism in protogalaxies increases in coherence over cosmic time, and with a hierarchical galaxy formation scenario, with the DLAs and LLSs exploring different stages of magnetic field evolution in galaxies.

  5. Effect of high-frequency repetitive transcranial magnetic stimulation on chronic central pain after mild traumatic brain injury: A pilot study.

    PubMed

    Choi, Gyu-Sik; Kwak, Sang Gyu; Lee, Han Do; Chang, Min Cheol

    2018-02-28

    Central pain can occur following traumatic brain injury, leading to poor functional recovery, limitation of activities of daily living, and decreased quality of life. The aim of this study was to determine whether high-frequency (10 Hz) repetitive transcranial magnetic stimulation, applied over the primary motor cortex of the affected hemisphere, can be used to manage chronic central pain after mild traumatic brain injury. Prospective randomized feasibility study. Twelve patients with mild traumatic brain injury and chronic central pain were randomly assigned to transcranial magnetic stimulation (high-frequency stimulation, 10 sessions) or sham groups. Diffuse tensor tractography revealed partially injured spinothalamocortical tracts in all recruited patients. A numerical rating scale (NRS) was used to evaluate pain intensity during pre-treatment and immediately after the 5th transcranial magnetic stimulation session (post1), 10th transcranial magnetic stimulation session (post2), and 1 (post3), 2 (post4), and 4 weeks (post 5) after finishing treatment. Physical and mental health status were evaluated using the Short Form 36 Health Survey (SF-36), including physical and mental component scores (PCS, MCS). The NRS score of the repetitive transcranial magnetic stimulation group was significantly lower than the sham group score at all clinical evaluation time-points during and after transcranial magnetic stimulation sessions. The transcranial magnetic stimulation group's SF-36 PCS score was significantly higher at post2, post3, post4, and post5 compared with the sham group. High-frequency transcranial magnetic stimulation may be used to manage chronic central pain and improve quality of life in patients with mild traumatic brain injury. However, this is a pilot study and further research is needed.

  6. Magnetically-assembled micro/mesopixels exhibiting light intensity enhancement in the (012) planes of fish guanine crystals

    NASA Astrophysics Data System (ADS)

    Chikashige, T.; Iwasaka, M.

    2018-05-01

    In this study, a new method was investigated to form light-reflecting dots at the micrometer scale using the magnetic orientations of biogenic guanine crystals obtained from fish skin and scales. The crystal platelets, possessing average dimensions of 5 μm×20 μm×100 nm, were dispersed in water and observed during exposure to vertical magnetic fields up to 5 T. The magnetic field direction was parallel to Earth's gravity, and allowed the narrowest edges of the crystals to be observed at the micrometer scale for the first time. The magnetic orientation process was initiated under conditions where the crystal platelets in water were laid on a glass substrate or where the platelets had random orientations. In the former case, the crystal platelets followed a two-stage magnetic orientation process where, in the first step, the platelet widths were aligned in the magnetic field direction. The second step required rotation of the ˜20-μm-long plates with respect to the Earth's gravity, where application of a 5 T magnetic field enabled their orientation. Real-time images of the magnetically aligning platelets provided new evidence that the crystal platelets also emitted reflected light from a very narrow window at two crystal planes (i.e., (0 1 ¯ 2 ¯ ) and (0 1 ¯ 2 )). In the latter case with random platelet orientation, spatially-condensed light-reflecting dots appeared while the guanine crystal platelets were floating and maintaining their orientation. The technique developed for controlling light-reflecting microscale objects in an aqueous medium can be applied to produce a type of microfluidic optical tool.

  7. Magnetic vector field tag and seal

    DOEpatents

    Johnston, Roger G.; Garcia, Anthony R.

    2004-08-31

    One or more magnets are placed in a container (preferably on objects inside the container) and the magnetic field strength and vector direction are measured with a magnetometer from at least one location near the container to provide the container with a magnetic vector field tag and seal. The location(s) of the magnetometer relative to the container are also noted. If the position of any magnet inside the container changes, then the measured vector fields at the these locations also change, indicating that the tag has been removed, the seal has broken, and therefore that the container and objects inside may have been tampered with. A hollow wheel with magnets inside may also provide a similar magnetic vector field tag and seal. As the wheel turns, the magnets tumble randomly inside, removing the tag and breaking the seal.

  8. Global enhancement and structure formation of the magnetic field in spiral galaxies

    NASA Astrophysics Data System (ADS)

    Khoperskov, Sergey A.; Khrapov, Sergey S.

    2018-01-01

    In this paper we study numerically large-scale magnetic field evolution and its enhancement in gaseous disks of spiral galaxies. We consider a set of models with the various spiral pattern parameters and the initial magnetic field strength with taking into account gas self-gravity and cooling and heating processes. In agreement with previous studies we find out that galactic magnetic field is mostly aligned with gaseous structures, however small-scale gaseous structures (spurs and clumps) are more chaotic than the magnetic field structure. In spiral arms magnetic field often coexists with the gas distribution, in the inter-arm region we see filamentary magnetic field structure. These filaments connect several isolated gaseous clumps. Simulations reveal the presence of the small-scale irregularities of the magnetic field as well as the reversal of magnetic field at the outer edge of the large-scale spurs. We provide evidences that the magnetic field in the spiral arms has a stronger mean-field component, and there is a clear inverse correlation between gas density and plasma-beta parameter, compared to the rest of the disk with a more turbulent component of the field and an absence of correlation between gas density and plasma-beta. We show the mean field growth up to >3-10 μG in the cold gas during several rotation periods (>500-800 Myr), whereas ratio between azimuthal and radial field is equal to >4/1. We find an enhancement of random and ordered components of the magnetic field. Mean field strength increases by a factor of >1.5-2.5 for models with various spiral pattern parameters. Random magnetic field component can reach up to 25% from the total strength. By making an analysis of the time-dependent evolution of the radial Poynting flux, we point out that the magnetic field strength is enhanced more strongly at the galactic outskirts which is due to the radial transfer of magnetic energy by the spiral arms pushing the magnetic field outward. Our results also support the presence of sufficient conditions for the development of magnetorotational instability at distances >11 kpc after >300 Myr of evolution.

  9. Spontaneous liquid crystal and ferromagnetic ordering of colloidal magnetic nanoplates

    PubMed Central

    Shuai, M.; Klittnick, A.; Shen, Y.; Smith, G. P.; Tuchband, M. R.; Zhu, C.; Petschek, R. G.; Mertelj, A.; Lisjak, D.; Čopič, M.; Maclennan, J. E.; Glaser, M. A.; Clark, N. A.

    2016-01-01

    Ferrofluids are familiar as colloidal suspensions of ferromagnetic nanoparticles in aqueous or organic solvents. The dispersed particles are randomly oriented but their moments become aligned if a magnetic field is applied, producing a variety of exotic and useful magnetomechanical effects. A longstanding interest and challenge has been to make such suspensions macroscopically ferromagnetic, that is having uniform magnetic alignment in the absence of a field. Here we report a fluid suspension of magnetic nanoplates that spontaneously aligns into an equilibrium nematic liquid crystal phase that is also macroscopically ferromagnetic. Its zero-field magnetization produces distinctive magnetic self-interaction effects, including liquid crystal textures of fluid block domains arranged in closed flux loops, and makes this phase highly sensitive, with it dramatically changing shape even in the Earth's magnetic field. PMID:26817823

  10. The formation of magnetic silicide Fe3Si clusters during ion implantation

    NASA Astrophysics Data System (ADS)

    Balakirev, N.; Zhikharev, V.; Gumarov, G.

    2014-05-01

    A simple two-dimensional model of the formation of magnetic silicide Fe3Si clusters during high-dose Fe ion implantation into silicon has been proposed and the cluster growth process has been computer simulated. The model takes into account the interaction between the cluster magnetization and magnetic moments of Fe atoms random walking in the implanted layer. If the clusters are formed in the presence of the external magnetic field parallel to the implanted layer, the model predicts the elongation of the growing cluster in the field direction. It has been proposed that the cluster elongation results in the uniaxial magnetic anisotropy in the plane of the implanted layer, which is observed in iron silicide films ion-beam synthesized in the external magnetic field.

  11. Magnetic properties of carbon-coated, ferromagnetic nanoparticles produced by a carbon-arc method

    NASA Astrophysics Data System (ADS)

    Brunsman, E. M.; Sutton, R.; Bortz, E.; Kirkpatrick, S.; Midelfort, K.; Williams, J.; Smith, P.; McHenry, M. E.; Majetich, S. A.; Artman, J. O.; De Graef, M.; Staley, S. W.

    1994-05-01

    The Krätschmer-Huffman carbon-arc method of preparing fullerenes has been used to generate carbon-coated transition metal (TM) and TM-carbide nanocrystallites. The magnetic nanocrystallites were extracted from the soot with a magnetic gradient field technique. For TM=Co the majority of nanocrystals exist as nominally spherical particles, 0.5-5 nm in radius. Hysteretic and temperature-dependent magnetic response, in randomly and magnetically aligned powder samples frozen in epoxy, correspond to fine particle magnetism associated with monodomain TM particles. The magnetization exhibits a unique functional dependence on H/T, and hysteresis below a blocking temperature TB. Below TB, the temperature dependence of the coercivity can be expressed as Hc=Hc0[1-(T/TB)1/2], where Hc0 is the 0 K coercivity.

  12. 40 CFR 205.54-2 - Sound data acquisition system.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... of 86 dB (rms) and the level indicated for an octave band of random noise of equal energy as the... Publication 179, Precision Sound Level Meters. (v) Magnetic tape recorders. No requirements are described in...) Calibrate tape recorders using the brand and type of magnetic tape used for actual data acquisition...

  13. A novel look at the pulsar force-free magnetosphere

    NASA Astrophysics Data System (ADS)

    Petrova, S. A.; Flanchik, A. B.

    2018-03-01

    The stationary axisymmetric force-free magnetosphere of a pulsar is considered. We present an exact dipolar solution of the pulsar equation, construct the magnetospheric model on its basis and examine its observational support. The new model has toroidal rather than common cylindrical geometry, in line with that of the plasma outflow observed directly as the pulsar wind nebula at much larger spatial scale. In its new configuration, the axisymmetric magnetosphere consumes the neutron star rotational energy much more efficiently, implying re-estimation of the stellar magnetic field, B_{new}0=3.3×10^{-4}B/P, where P is the pulsar period. Then the 7-order scatter of the magnetic field derived from the rotational characteristics of the pulsars observed appears consistent with the \\cotχ-law, where χ is a random quantity uniformly distributed in the interval [0,π/2]. Our result is suggestive of a unique actual magnetic field strength of the neutron stars along with a random angle between the magnetic and rotational axes and gives insight into the neutron star unification on the geometrical basis.

  14. Quantum Hall effect in epitaxial graphene with permanent magnets.

    PubMed

    Parmentier, F D; Cazimajou, T; Sekine, Y; Hibino, H; Irie, H; Glattli, D C; Kumada, N; Roulleau, P

    2016-12-06

    We have observed the well-kown quantum Hall effect (QHE) in epitaxial graphene grown on silicon carbide (SiC) by using, for the first time, only commercial NdFeB permanent magnets at low temperature. The relatively large and homogeneous magnetic field generated by the magnets, together with the high quality of the epitaxial graphene films, enables the formation of well-developed quantum Hall states at Landau level filling factors v = ±2, commonly observed with superconducting electro-magnets. Furthermore, the chirality of the QHE edge channels can be changed by a top gate. These results demonstrate that basic QHE physics are experimentally accessible in graphene for a fraction of the price of conventional setups using superconducting magnets, which greatly increases the potential of the QHE in graphene for research and applications.

  15. Structural disorder and elementary magnetic properties of triangular lattice ErMgGaO 4 single crystals

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Cevallos, F. Alex; Stolze, Karoline; Cava, Robert J.

    The single crystal growth, structure, and basic magnetic properties of ErMgGaO 4 are reported. The structure consists of triangular layers of magnetic ErO 6 octahedra separated by a double layer of randomly occupied non-magnetic (Ga,Mg)O 5 bipyramids. The Er atoms are positionally disordered. Magnetic measurements parallel and perpendicular to the c axis of a single crystal reveal dominantly antiferromagnetic interactions, with a small degree of magnetic anisotropy. A weighted average of the directional data suggests an antiferromagnetic Curie Weiss temperature of approximately -30 K. Below 10 K the temperature dependences of the inverse susceptibilities in the in-plane and perpendicular-to planemore » directions are parallel, indicative of an isotropic magnetic moment at low temperatures. In conclusion, no sign of magnetic ordering is observed above 1.8 K, suggesting that ErMgGaO 4 is a geometrically frustrated magnet.« less

  16. Structural disorder and elementary magnetic properties of triangular lattice ErMgGaO 4 single crystals

    DOE PAGES

    Cevallos, F. Alex; Stolze, Karoline; Cava, Robert J.

    2018-03-23

    The single crystal growth, structure, and basic magnetic properties of ErMgGaO 4 are reported. The structure consists of triangular layers of magnetic ErO 6 octahedra separated by a double layer of randomly occupied non-magnetic (Ga,Mg)O 5 bipyramids. The Er atoms are positionally disordered. Magnetic measurements parallel and perpendicular to the c axis of a single crystal reveal dominantly antiferromagnetic interactions, with a small degree of magnetic anisotropy. A weighted average of the directional data suggests an antiferromagnetic Curie Weiss temperature of approximately -30 K. Below 10 K the temperature dependences of the inverse susceptibilities in the in-plane and perpendicular-to planemore » directions are parallel, indicative of an isotropic magnetic moment at low temperatures. In conclusion, no sign of magnetic ordering is observed above 1.8 K, suggesting that ErMgGaO 4 is a geometrically frustrated magnet.« less

  17. Correlated magnetic impurities in a superconductor: electron density profiles and robustness of superconductivity.

    PubMed

    Sacramento, P D; Dugaev, V K; Vieira, V R; Araújo, M A N

    2010-01-20

    The insertion of magnetic impurities in a conventional superconductor leads to various effects. In this work we show that the electron density is affected by the spins (considered as classical) both locally and globally. The charge accumulation is solved self-consistently. This affects the transport properties along magnetic domain walls. Also, we show that superconductivity is more robust if the spin locations are not random but correlated. © 2010 IOP Publishing Ltd

  18. Enhancing the Selection of Backoff Interval Using Fuzzy Logic over Wireless Ad Hoc Networks

    PubMed Central

    Ranganathan, Radha; Kannan, Kathiravan

    2015-01-01

    IEEE 802.11 is the de facto standard for medium access over wireless ad hoc network. The collision avoidance mechanism (i.e., random binary exponential backoff—BEB) of IEEE 802.11 DCF (distributed coordination function) is inefficient and unfair especially under heavy load. In the literature, many algorithms have been proposed to tune the contention window (CW) size. However, these algorithms make every node select its backoff interval between [0, CW] in a random and uniform manner. This randomness is incorporated to avoid collisions among the nodes. But this random backoff interval can change the optimal order and frequency of channel access among competing nodes which results in unfairness and increased delay. In this paper, we propose an algorithm that schedules the medium access in a fair and effective manner. This algorithm enhances IEEE 802.11 DCF with additional level of contention resolution that prioritizes the contending nodes according to its queue length and waiting time. Each node computes its unique backoff interval using fuzzy logic based on the input parameters collected from contending nodes through overhearing. We evaluate our algorithm against IEEE 802.11, GDCF (gentle distributed coordination function) protocols using ns-2.35 simulator and show that our algorithm achieves good performance. PMID:25879066

  19. Preface: phys. stat. sol. (a) 201/8

    NASA Astrophysics Data System (ADS)

    Shin, Sung-Chul

    2004-06-01

    The KMS/SOMMA Meeting 2003 was held 3-6 December 2003 at Spapia Hotel, Daejeon, Korea. It was the 5th SOMMA (International Symposium on Magnetic Materials and Applications) organized by ReCAMM (Research Center for Advanced Magnetic Materials) of Chungnam National University. Since 2002, the Korean Magnetics Society (KMS) winter conference has been jointly held with SOMMA. This was the second time to have a KMS/SOMMA joint meeting. The main objective of the meeting was to provide an international forum to discuss up-to-date results on magnetism and magnetic materials. The conference brought together 360 participants from 12 countries. Sessions of the meeting were: Theory and Fundamentals, Magnetic Random Access Memory, Spintronics, Information Storage, Nanostructured Materials, Sensors, and Interdisciplinary. In these seven sessions, 325 papers were presented including 66 oral and 259 poster presentations. Since the symposium was held in Korea, this enabled a large number of Asian scientists to attend: 239 from Korea, 41 from Japan, 7 from Taiwan, and 5 from China.The conference program had 25 invited and plenary speakers. They were Y. Ando (Tohoku U.), M. Inoue (Toyohashi U. Tech), H. Kubota (Tohoku U.), K. Mohri (Nagoya U.), M. Sahashi, M. Takahashi, K. Takanashi, M. Tsunoda (Tohoku U.), and H. Yoda (Toshiba) from Japan; A. J. Freeman (Northwestern U.), A. T. Hanbicki (NRL), F. B. Humphrey (Boston U.), and S. Sun (IBM) from the USA; J. D. Boeck (IMEC, Belgium), B. Dieny (CEA, France), N. Garcia (CSIS, Spain), G. Reiss (Bielefeld U., Germany), T. Stobiecki (U. M. & M. Krakow, Poland), and M. Wolfram (Singulus Tech, Germany) from Europe; C. G. Kim, D. J. Kim (CNU), T. W. Kim (SAIT), S. H. Lim (KIST), Sung-Chul Shin (KAIST), and Yoon Hee Chung (POSTEC) from Korea.For the first time, the SOMMA Proceedings appear in physica status solidi. The Editors hope that the Proceedings could provide chances for deeper and wider understanding of the presentations as well as for enhanced relationship between all participants. We deeply appreciate the help of the editorial staff of physica status solidi for their efficient and kind help during the paper preparations and publications.Finally, we would like to take this opportunity to thank all members of the Advisory Committee, Organizing Committee, referees, and KMS staff for their effort before, during, and after the meeting.

  20. Preface: phys. stat. sol. (b) 241/7

    NASA Astrophysics Data System (ADS)

    Shin, Sung-Chul

    2004-06-01

    The KMS/SOMMA Meeting 2003 was held 3-6 December 2003 at Spapia Hotel, Daejeon, Korea. It was the 5th SOMMA (International Symposium on Magnetic Materials and Applications) organized by ReCAMM (Research Center for Advanced Magnetic Materials) of Chungnam National University. Since 2002, the Korean Magnetics Society (KMS) winter conference has been jointly held with SOMMA. This was the second time to have a KMS/SOMMA joint meeting.The main objective of the meeting was to provide an international forum to discuss up-to-date results on magnetism and magnetic materials. The conference brought together 360 participants from 12 countries. Sessions of the meeting were: Theory and Fundamentals, Magnetic Random Access Memory, Spintronics, Information Storage, Nanostructured Materials, Sensors, and Interdisciplinary. In these seven sessions, 325 papers were presented including 66 oral and 259 poster presentations. Since the symposium was held in Korea, this enabled a large number of Asian scientists to attend: 239 from Korea, 41 from Japan, 7 from Taiwan, and 5 from China.The conference program had 25 invited and plenary speakers. They were Y. Ando (Tohoku U.), M. Inoue (Toyohashi U. Tech), H. Kubota (Tohoku U.), K. Mohri (Nagoya U.), M. Sahashi, M. Takahashi, K. Takanashi, M. Tsunoda (Tohoku U.), and H. Yoda (Toshiba) from Japan; A. J. Freeman (Northwestern U.), A. T. Hanbicki (NRL), F. B. Humphrey (Boston U.), and S. Sun (IBM) from the USA; J. D. Boeck (IMEC, Belgium), B. Dieny (CEA, France), N. Garcia (CSIS, Spain), G. Reiss (Bielefeld U., Germany), T. Stobiecki (U. M. & M. Krakow, Poland), and M. Wolfram (Singulus Tech, Germany) from Europe; C. G. Kim, D. J. Kim (CNU), T. W. Kim (SAIT), S. H. Lim (KIST), Sung-Chul Shin (KAIST), and Yoon Hee Chung (POSTEC) from Korea.For the first time, the SOMMA Proceedings appear in physica status solidi. The Editors hope that the Proceedings could provide chances for deeper and wider understanding of the presentations as well as for enhanced relationship between all participants. We deeply appreciate the help of the editorial staff of physica status solidi for their efficient and kind help during the paper preparations and publications.Finally, we would like to take this opportunity to thank all members of the Advisory Committee, Organizing Committee, referees, and KMS staff for their effort before, during, and after the meeting.

  1. Traffic management mechanism for intranets with available-bit-rate access to the Internet

    NASA Astrophysics Data System (ADS)

    Hassan, Mahbub; Sirisena, Harsha R.; Atiquzzaman, Mohammed

    1997-10-01

    The design of a traffic management mechanism for intranets connected to the Internet via an available bit rate access- link is presented. Selection of control parameters for this mechanism for optimum performance is shown through analysis. An estimate for packet loss probability at the access- gateway is derived for random fluctuation of available bit rate of the access-link. Some implementation strategies of this mechanism in the standard intranet protocol stack are also suggested.

  2. Natural remananent magnetization acquisition through sediment mixing: theory and implications for relative paleointensity

    NASA Astrophysics Data System (ADS)

    Egli, Ramon; Zhao, Xiangyu

    2015-04-01

    We present a general theory on the acquisition of natural remanent magnetizations (NRM) in sediment under the influence of (a) magnetic torques, (b) randomizing torques (e.g. from bioturbation), and (c) torques resulting from interaction forces between remanence carriers and other particles. Dynamic equilibrium between (a) and (b) in the water column and sediment-water interface produce a detrital remanent magnetization (DRM), while much stronger randomizing forces occur in the mixed layer of sediment due to bioturbation forces. These generate a so-called mixing remanent magnetization (MRM), which is stabilized by interaction forces. During the time required to cross the mixed layer, DRM is lost and MRM is acquired at a rate that depends on bioturbation intensity. Both processes are governed by the same MRM lock-in function. The final NRM intensity is controlled mainly by a single parameter defined as the product of rotational diffusion constant and mixed layer thickness, divided by the sedimentation rate. This parameter defines three regimes: (1) slow mixing, leading to DRM preservation and insignificant MRM acquisition, (2) fast mixing with MRM acquisition and full randomization of the original DRM, and (3) intermediate mixing. Because the acquisition efficiency of DRM is expectedly larger than that of a MRM, MRM is particularly sensitive to the mixing rate in case of intermediate regimes, and generates variable NRM acquisition efficiencies. Our model explains (1) lock-in delays that can be matched with empirical reconstructions from paleomagnetic records, (2) the existence of small lock-in depths leading to DRM preservation, (3) NRM acquisition efficiencies of magnetofossil-rich sediments, and (4) relative paleointensity artifacts reported in some recent studies.

  3. Remote control of an MR imaging study via tele-collaboration tools

    NASA Astrophysics Data System (ADS)

    Sullivan, John M., Jr.; Mullen, Julia S.; Benz, Udo A.; Schmidt, Karl F.; Murugavel, Murali; Chen, Wei; Ghadyani, Hamid

    2005-04-01

    In contrast to traditional 'video conferencing' the Access Grid (AG), developed by Argonne National Laboratory, is a collaboration of audio, video and shared application tools which provide the 'persistent presence' of each participant. Among the shared application tools are the ability to share viewing and control of presentations, browsers, images and movies. When used in conjunction with Virtual Network Computing (VNC) software, an investigator can interact with colleagues at a remote site, and control remote systems via local keyboard and mouse commands. This combination allows for effective viewing and discussion of information, i.e. data, images, and results. It is clear that such an approach when applied to the medical sciences will provide a means by which a team of experts can not only access, but interact and control medical devices for the purpose of experimentation, diagnosis, surgery and therapy. We present the development of an application node at our 4.7 Tesla MR magnet facility, and a demonstration of remote investigator control of the magnet. A local magnet operator performs manual tasks such as loading the test subject into the magnet and administering the stimulus associated with the functional MRI study. The remote investigator has complete control of the magnet console. S/he can adjust the gradient coil settings, the pulse sequence, image capture frequency, etc. A geographically distributed audience views and interacts with the remote investigator and local MR operator. This AG demonstration of MR magnet control illuminates the potential of untethered medical experiments, procedures and training.

  4. Ezetimibe for the Treatment of Nonalcoholic Steatohepatitis: Assessment by Novel Magnetic Resonance Imaging and Magnetic Resonance Elastography in a Randomized Trial (MOZART Trial)

    PubMed Central

    Loomba, Rohit; Sirlin, Claude B; Ang, Brandon; Bettencourt, Ricki; Jain, Rashmi; Salotti, Joanie; Soaft, Linda; Hooker, Jonathan; Kono, Yuko; Bhatt, Archana; Hernandez, Laura; Nguyen, Phirum; Noureddin, Mazen; Haufe, William; Hooker, Catherine; Yin, Meng; Ehman, Richard; Lin, Grace Y; Valasek, Mark A; Brenner, David A; Richards, Lisa

    2015-01-01

    Ezetimibe inhibits intestinal cholesterol absorption and lowers low-density lipoprotein cholesterol. Uncontrolled studies have suggested that it reduces liver fat as estimated by ultrasound in nonalcoholic steatohepatitis (NASH). Therefore, we aimed to examine the efficacy of ezetimibe versus placebo in reducing liver fat by the magnetic resonance imaging-derived proton density-fat fraction (MRI-PDFF) and liver histology in patients with biopsy-proven NASH. In this randomized, double-blind, placebo-controlled trial, 50 patients with biopsy-proven NASH were randomized to either ezetimibe 10 mg orally daily or placebo for 24 weeks. The primary outcome was a change in liver fat as measured by MRI-PDFF in colocalized regions of interest within each of the nine liver segments. Novel assessment by two-dimensional and three-dimensional magnetic resonance elastography was also performed. Ezetimibe was not significantly better than placebo at reducing liver fat as measured by MRI-PDFF (mean difference between the ezetimibe and placebo arms -1.3%, P = 0.4). Compared to baseline, however, end-of-treatment MRI-PDFF was significantly lower in the ezetimibe arm (15%-11.6%, P < 0.016) but not in the placebo arm (18.5%-16.4%, P = 0.15). There were no significant differences in histologic response rates, serum alanine aminotransferase and aspartate aminotransferase levels, or longitudinal changes in two-dimensional and three-dimensional magnetic resonance elastography-derived liver stiffness between the ezetimibe and placebo arms. Compared to histologic nonresponders (25/35), histologic responders (10/35) had a significantly greater reduction in MRI-PDFF (-4.35 ± 4.9% versus -0.30 ± 4.1%, P < 0.019). Conclusions: Ezetimibe did not significantly reduce liver fat in NASH. This trial demonstrates the application of colocalization of MRI-PDFF-derived fat maps and magnetic resonance elastography-derived stiffness maps of the liver before and after treatment to noninvasively assess treatment response in NASH. (Hepatology 2015;61:1239–1250) PMID:25482832

  5. Probe manipulators for Wendelstein 7-X and their interaction with the magnetic topology

    NASA Astrophysics Data System (ADS)

    M, RACK; D, HÖSCHEN; D, REITER; B, UNTERBERG; J, W. COENEN; S, BREZINSEK; O, NEUBAUER; S, BOZHENKOV; G, CZYMEK; Y, LIANG; M, HUBENY; Ch, LINSMEIER; the Wendelstein 7-X Team

    2018-05-01

    Probe manipulators are a versatile addition to typical plasma edge diagnostics. Equipped with material samples they allow for detailed investigation of plasma–wall interaction processes, such as material erosion, deposition or impurity transport pathways. When combined with electrical probes, a study of scrape-off layer and plasma edge density, temperature and flow profiles as well as magnetic topologies is possible. A mid-plane manipulator is already in operation on Wendelstein 7-X. A system in the divertor region is currently under development. In the present paper we discuss the critical issue of heat and power loads, power redistribution and experimental access to the complex magnetic topology of Wendelstein 7-X. All the aforementioned aspects are of relevance for the design and operation of a probe manipulator in a device like Wendelstein 7-X. A focus is put on the topological region that is accessible for the different coil current configurations at Wendelstein 7-X and the power load on the manipulator with respect to the resulting different magnetic configurations. Qualitative analysis of power loads on plasma-facing components is performed using a numerical tracer particle diffusion tool provided via the Wendelstein 7-X Webservices.

  6. Nanocluster building blocks of artificial square spin ice: Stray-field studies of thermal dynamics

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Pohlit, Merlin, E-mail: pohlit@physik.uni-frankfurt.de; Porrati, Fabrizio; Huth, Michael

    We present measurements of the thermal dynamics of a Co-based single building block of an artificial square spin ice fabricated by focused electron-beam-induced deposition. We employ micro-Hall magnetometry, an ultra-sensitive tool to study the stray field emanating from magnetic nanostructures, as a new technique to access the dynamical properties during the magnetization reversal of the spin-ice nanocluster. The obtained hysteresis loop exhibits distinct steps, displaying a reduction of their “coercive field” with increasing temperature. Therefore, thermally unstable states could be repetitively prepared by relatively simple temperature and field protocols allowing one to investigate the statistics of their switching behavior withinmore » experimentally accessible timescales. For a selected switching event, we find a strong reduction of the so-prepared states' “survival time” with increasing temperature and magnetic field. Besides the possibility to control the lifetime of selected switching events at will, we find evidence for a more complex behavior caused by the special spin ice arrangement of the macrospins, i.e., that the magnetic reversal statistically follows distinct “paths” most likely driven by thermal perturbation.« less

  7. Optimization of the random multilayer structure to break the random-alloy limit of thermal conductivity

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Wang, Yan; Gu, Chongjie; Ruan, Xiulin, E-mail: ruan@purdue.edu

    2015-02-16

    A low lattice thermal conductivity (κ) is desired for thermoelectrics, and a highly anisotropic κ is essential for applications such as magnetic layers for heat-assisted magnetic recording, where a high cross-plane (perpendicular to layer) κ is needed to ensure fast writing while a low in-plane κ is required to avoid interaction between adjacent bits of data. In this work, we conduct molecular dynamics simulations to investigate the κ of superlattice (SL), random multilayer (RML) and alloy, and reveal that RML can have 1–2 orders of magnitude higher anisotropy in κ than SL and alloy. We systematically explore how the κmore » of SL, RML, and alloy changes relative to each other for different bond strength, interface roughness, atomic mass, and structure size, which provides guidance for choosing materials and structural parameters to build RMLs with optimal performance for specific applications.« less

  8. Leveraging Random Number Generation for Mastery of Learning in Teaching Quantitative Research Courses via an E-Learning Method

    ERIC Educational Resources Information Center

    Boonsathorn, Wasita; Charoen, Danuvasin; Dryver, Arthur L.

    2014-01-01

    E-Learning brings access to a powerful but often overlooked teaching tool: random number generation. Using random number generation, a practically infinite number of quantitative problem-solution sets can be created. In addition, within the e-learning context, in the spirit of the mastery of learning, it is possible to assign online quantitative…

  9. Magnetic Ureteral Stent Removal Without Cystoscopy: A Randomized Controlled Trial.

    PubMed

    Rassweiler, Marie-Claire; Michel, Maurice-Stephan; Ritter, Manuel; Honeck, Patrick

    2017-08-01

    Ureteral stenting is a common procedure in urology. The cystoscopic removal of Double-J stents (DJ) causes unpleasant side effects with a negative impact on patient's quality of life. The aim of our study was to evaluate this newly developed magnetic DJ and compare it with a standard DJ regarding quality of life with indwelling DJs as well as discomfort during the removal. The magnetic DJ (Blackstar, Urotech [Achenmühle, Germany]) is a standard 7F ureteral stent with a small magnetic cube fixed through a string on the loop of the distal part of the stent. For DJ removal, a special catheter-like retrieval instrument with a magnetic tip is inserted, the two magnets connect and the retrieval instrument is removed with the DJ. We first tested this DJ in 20 cases. Afterward we evaluated 40 consecutive cases that required a DJ placement after ureterorenoscopy in a prospective randomized manner. The quality of life was assessed by the ureteral stent symptom questionnaire. A visual analogue scale was used to document the pain by DJ removal. There was a significant difference regarding the pain location with the indwelling DJ (p = 0.038). The maximum pain was located in the lower abdomen and/or around the bladder (48%) with the magnetic DJ, whereas the standard DJ caused flank pain in 54% of the patients. The mean time for the magnetic DJ removal including preparation and cleaning as for a transurethral catheter insertion was 9.55 [7-14] minutes, whereas the mean time for the cystoscopic DJ removal was 21.35 [18-30] minutes. The pain caused by the removal of the magnetic DJ was significantly less than that caused by the cystoscopic DJ removal (p = 0.019). The discomfort caused by the indwelling magnetic DJ is comparable with that caused by the standard DJ. However, the magnetic DJ removal is less painful and faster.

  10. Zero-field optical magnetic resonance study of phosphorus donors in 28-silicon

    NASA Astrophysics Data System (ADS)

    Morse, Kevin J.; Dluhy, Phillip; Huber, Julian; Salvail, Jeff Z.; Saeedi, Kamyar; Riemann, Helge; Abrosimov, Nikolay V.; Becker, Peter; Pohl, Hans-Joachim; Simmons, S.; Thewalt, M. L. W.

    2018-03-01

    Donor spins in silicon are some of the most promising qubits for upcoming solid-state quantum technologies. The nuclear spins of phosphorus donors in enriched silicon have among the longest coherence times of any solid-state system as well as simultaneous high fidelity qubit initialization, manipulation, and readout. Here we characterize the phosphorus in silicon system in the regime of "zero" magnetic field, where a singlet-triplet spin clock transition can be accessed, using laser spectroscopy and magnetic resonance methods. We show the system can be optically hyperpolarized and has ˜10 s Hahn echo coherence times, even for applied static magnetic fields below Earth's field.

  11. Review of Journal of Cardiovascular Magnetic Resonance 2009

    PubMed Central

    2010-01-01

    There were 56 articles published in the Journal of Cardiovascular Magnetic Resonance in 2009. The editors were impressed with the high quality of the submissions, of which our acceptance rate was about 40%. In accordance with open-access publishing, the articles go on-line as they are accepted with no collating of the articles into sections or special thematic issues. We have therefore chosen to briefly summarise the papers in this article for quick reference for our readers in broad areas of interest, which we feel will be useful to practitioners of cardiovascular magnetic resonance (CMR). In some cases where it is considered useful, the articles are also put into the wider context with a short narrative and recent CMR references. It has been a privilege to serve as the Editor of the JCMR this past year. I hope that you find the open-access system increases wider reading and citation of your papers, and that you will continue to send your quality manuscripts to JCMR for publication. PMID:20302618

  12. Three-dimensional mapping of microcircuit correlation structure

    PubMed Central

    Cotton, R. James; Froudarakis, Emmanouil; Storer, Patrick; Saggau, Peter; Tolias, Andreas S.

    2013-01-01

    Great progress has been made toward understanding the properties of single neurons, yet the principles underlying interactions between neurons remain poorly understood. Given that connectivity in the neocortex is locally dense through both horizontal and vertical connections, it is of particular importance to characterize the activity structure of local populations of neurons arranged in three dimensions. However, techniques for simultaneously measuring microcircuit activity are lacking. We developed an in vivo 3D high-speed, random-access two-photon microscope that is capable of simultaneous 3D motion tracking. This allows imaging from hundreds of neurons at several hundred Hz, while monitoring tissue movement. Given that motion will induce common artifacts across the population, accurate motion tracking is absolutely necessary for studying population activity with random-access based imaging methods. We demonstrate the potential of this imaging technique by measuring the correlation structure of large populations of nearby neurons in the mouse visual cortex, and find that the microcircuit correlation structure is stimulus-dependent. Three-dimensional random access multiphoton imaging with concurrent motion tracking provides a novel, powerful method to characterize the microcircuit activity in vivo. PMID:24133414

  13. Cost effectiveness of different central venous approaches for port placement and use in adult oncology patients: evidence from a randomized three-arm trial.

    PubMed

    Biffi, Roberto; Pozzi, Simonetta; Bonomo, Guido; Della Vigna, Paolo; Monfardini, Lorenzo; Radice, Davide; Rotmensz, Nicole; Zampino, Maria Giulia; Fazio, Nicola; Orsi, Franco

    2014-11-01

    No randomized trials have so far investigated the cost effectiveness of different methods for implantation and use of central venous ports in oncology patients. Overall, 403 patients eligible for receiving intravenous chemotherapy for solid tumours were randomly assigned to implantation of a single type of port, either through a percutaneous landmark access to the internal jugular vein, an ultrasound (US)-guided access to the subclavian vein, or a surgical cut-down access through the cephalic vein at the deltoid-pectoralis groove. Insertion and maintenance costs were estimated by obtaining the charges for an average implant and use, while the costs of the management of complications were analytically assessed. The total cost was defined as the purchase cost plus the insertion cost plus the maintenance cost plus the cost of treatment of the complications, if any. A total of 401 patients were evaluable-132 with the internal jugular vein, 136 with the subclavian vein and 133 with the cephalic vein access. No differences were found for the rate of early complications. The US-guided subclavian insertion site had significantly lower failures. Infections occurred in 1, 3, and 3 patients (internal jugular, subclavian, and cephalic access, respectively; p = 0.464), whereas venous thrombosis was observed in 15, 8, and 11 patients, respectively (p = 0.272). Mean cost for purchase, implantation, diagnosis and treatment of complications in each patient was 2,167.85 for subclavian US-guided, 2,335.87 for cephalic, and 2,384.10 for internal jugular access, respectively (p = 0.0001). US real-time guidance to the subclavian vein resulted in the most cost-effective method of central venous port placement and use.

  14. Nuclear magnetic resonance in high magnetic field: Application to condensed matter physics

    NASA Astrophysics Data System (ADS)

    Berthier, Claude; Horvatić, Mladen; Julien, Marc-Henri; Mayaffre, Hadrien; Krämer, Steffen

    2017-05-01

    In this review, we describe the potentialities offered by the nuclear magnetic resonance (NMR) technique to explore at a microscopic level new quantum states of condensed matter induced by high magnetic fields. We focus on experiments realised in resistive (up to 34 T) or hybrid (up to 45 T) magnets, which open a large access to these quantum phase transitions. After an introduction on NMR observables, we consider several topics: quantum spin systems (spin-Peierls transition, spin ladders, spin nematic phases, magnetisation plateaus, and Bose-Einstein condensation of triplet excitations), the field-induced charge density wave (CDW) in high-Tc superconductors, and exotic superconductivity including the Fulde-Ferrel-Larkin-Ovchinnikov superconducting state and the field-induced superconductivity due to the Jaccarino-Peter mechanism.

  15. Remote temperature distribution sensing using permanent magnets

    DOE PAGES

    Chen, Yi; Guba, Oksana; Brooks, Carlton F.; ...

    2016-10-31

    Remote temperature sensing is essential for applications in enclosed vessels where feedthroughs or optical access points are not possible. A unique sensing method for measuring the temperature of multiple closely-spaced points is proposed using permanent magnets and several three-axis magnetic field sensors. The magnetic field theory for multiple magnets is discussed and a solution technique is presented. Experimental calibration procedures, solution inversion considerations and methods for optimizing the magnet orientations are described in order to obtain low-noise temperature estimates. The experimental setup and the properties of permanent magnets are shown. Finally, experiments were conducted to determine the temperature of ninemore » magnets in different configurations over a temperature range of 5 to 60 degrees Celsius and for a sensor-to-magnet distance of up to 35 mm. Furthermore, to show the possible applications of this sensing system for measuring temperatures through metal walls, additional experiments were conducted inside an opaque 304 stainless steel cylinder.« less

  16. Orbital effect of the magnetic field in dynamical mean-field theory

    NASA Astrophysics Data System (ADS)

    Acheche, S.; Arsenault, L.-F.; Tremblay, A.-M. S.

    2017-12-01

    The availability of large magnetic fields at international facilities and of simulated magnetic fields that can reach the flux-quantum-per-unit-area level in cold atoms calls for systematic studies of orbital effects of the magnetic field on the self-energy of interacting systems. Here we demonstrate theoretically that orbital effects of magnetic fields can be treated within single-site dynamical mean-field theory with a translationally invariant quantum impurity problem. As an example, we study the one-band Hubbard model on the square lattice using iterated perturbation theory as an impurity solver. We recover the expected quantum oscillations in the scattering rate, and we show that the magnetic fields allow the interaction-induced effective mass to be measured through the single-particle density of states accessible in tunneling experiments. The orbital effect of magnetic fields on scattering becomes particularly important in the Hofstadter butterfly regime.

  17. High-field open versus short-bore magnetic resonance imaging of the spine: a randomized controlled comparison of image quality.

    PubMed

    Enders, Judith; Rief, Matthias; Zimmermann, Elke; Asbach, Patrick; Diederichs, Gerd; Wetz, Christoph; Siebert, Eberhard; Wagner, Moritz; Hamm, Bernd; Dewey, Marc

    2013-01-01

    The purpose of the present study was to compare the image quality of spinal magnetic resonance (MR) imaging performed on a high-field horizontal open versus a short-bore MR scanner in a randomized controlled study setup. Altogether, 93 (80% women, mean age 53) consecutive patients underwent spine imaging after random assignement to a 1-T horizontal open MR scanner with a vertical magnetic field or a 1.5-T short-bore MR scanner. This patient subset was part of a larger cohort. Image quality was assessed by determining qualitative parameters, signal-to-noise (SNR) and contrast-to-noise ratios (CNR), and quantitative contour sharpness. The image quality parameters were higher for short-bore MR imaging. Regarding all sequences, the relative differences were 39% for the mean overall qualitative image quality, 53% for the mean SNR values, and 34-37% for the quantitative contour sharpness (P<0.0001). The CNR values were also higher for images obtained with the short-bore MR scanner. No sequence was of very poor (nondiagnostic) image quality. Scanning times were significantly longer for examinations performed on the open MR scanner (mean: 32±22 min versus 20±9 min; P<0.0001). In this randomized controlled comparison of spinal MR imaging with an open versus a short-bore scanner, short-bore MR imaging revealed considerably higher image quality with shorter scanning times. ClinicalTrials.gov NCT00715806.

  18. High-Field Open versus Short-Bore Magnetic Resonance Imaging of the Spine: A Randomized Controlled Comparison of Image Quality

    PubMed Central

    Zimmermann, Elke; Asbach, Patrick; Diederichs, Gerd; Wetz, Christoph; Siebert, Eberhard; Wagner, Moritz; Hamm, Bernd; Dewey, Marc

    2013-01-01

    Background The purpose of the present study was to compare the image quality of spinal magnetic resonance (MR) imaging performed on a high-field horizontal open versus a short-bore MR scanner in a randomized controlled study setup. Methods Altogether, 93 (80% women, mean age 53) consecutive patients underwent spine imaging after random assignement to a 1-T horizontal open MR scanner with a vertical magnetic field or a 1.5-T short-bore MR scanner. This patient subset was part of a larger cohort. Image quality was assessed by determining qualitative parameters, signal-to-noise (SNR) and contrast-to-noise ratios (CNR), and quantitative contour sharpness. Results The image quality parameters were higher for short-bore MR imaging. Regarding all sequences, the relative differences were 39% for the mean overall qualitative image quality, 53% for the mean SNR values, and 34–37% for the quantitative contour sharpness (P<0.0001). The CNR values were also higher for images obtained with the short-bore MR scanner. No sequence was of very poor (nondiagnostic) image quality. Scanning times were significantly longer for examinations performed on the open MR scanner (mean: 32±22 min versus 20±9 min; P<0.0001). Conclusions In this randomized controlled comparison of spinal MR imaging with an open versus a short-bore scanner, short-bore MR imaging revealed considerably higher image quality with shorter scanning times. Trial Registration ClinicalTrials.gov NCT00715806 PMID:24391767

  19. Mobile access to virtual randomization for investigator-initiated trials.

    PubMed

    Deserno, Thomas M; Keszei, András P

    2017-08-01

    Background/aims Randomization is indispensable in clinical trials in order to provide unbiased treatment allocation and a valid statistical inference. Improper handling of allocation lists can be avoided using central systems, for example, human-based services. However, central systems are unaffordable for investigator-initiated trials and might be inaccessible from some places, where study subjects need allocations. We propose mobile access to virtual randomization, where the randomization lists are non-existent and the appropriate allocation is computed on demand. Methods The core of the system architecture is an electronic data capture system or a clinical trial management system, which is extended by an R interface connecting the R server using the Java R Interface. Mobile devices communicate via the representational state transfer web services. Furthermore, a simple web-based setup allows configuring the appropriate statistics by non-statisticians. Our comprehensive R script supports simple randomization, restricted randomization using a random allocation rule, block randomization, and stratified randomization for un-blinded, single-blinded, and double-blinded trials. For each trial, the electronic data capture system or the clinical trial management system stores the randomization parameters and the subject assignments. Results Apps are provided for iOS and Android and subjects are randomized using smartphones. After logging onto the system, the user selects the trial and the subject, and the allocation number and treatment arm are displayed instantaneously and stored in the core system. So far, 156 subjects have been allocated from mobile devices serving five investigator-initiated trials. Conclusion Transforming pre-printed allocation lists into virtual ones ensures the correct conduct of trials and guarantees a strictly sequential processing in all trial sites. Covering 88% of all randomization models that are used in recent trials, virtual randomization becomes available for investigator-initiated trials and potentially for large multi-center trials.

  20. Instrumentation of the variable-angle magneto-optic ellipsometer and its application to M-O media and other non-magnetic films

    NASA Technical Reports Server (NTRS)

    Zhou, Andy F.; Erwin, J. Kevin; Mansuripur, M.

    1992-01-01

    A new and comprehensive dielectric tensor characterization instrument is presented for characterization of magneto-optical recording media and non-magnetic thin films. Random and systematic errors of the system are studied. A series of TbFe, TbFeCo, and Co/Pt samples with different composition and thicknesses are characterized for their optical and magneto-optical properties. The optical properties of several non-magnetic films are also measured.

  1. Micromagnetic Simulation of Thermal Effects in Magnetic Nanostructures

    DTIC Science & Technology

    2003-01-01

    NiFe magnetic nano- elements are calculated. INTRODUCTION With decreasing size of magnetic nanostructures thermal effects become increasingly important...thermal field. The thermal field is assumed to be a Gaussian random process with the following statistical properties : (H,,,(t))=0 and (H,I.(t),H,.1(t...following property DI " =VE(M’’) - [VE(M"’)• t] t =0, for k =1.m (12) 186 The optimal path can be found using an iterative scheme. In each iteration step the

  2. Nonadiabatic Berry phase in nanocrystalline magnets

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Skomski, R.; Sellmyer, D. J.

    2016-12-20

    In this study, it is investigated how a Berry phase is created in polycrystalline nanomagnets and how the phase translates into an emergent magnetic field and into a topological Hall-effect contribution. The analysis starts directly from the spin of the conduction electrons and does not involve any adiabatic Hamiltonian. Completely random spin alignment in the nanocrystallites does not lead to a nonzero emergent field, but a modulation of the local magnetization does. As an explicit example, we consider a wire with a modulated cone angle.

  3. Anisotropy of low-energy Galactic cosmic rays in the outer heliosheath

    NASA Astrophysics Data System (ADS)

    Zhang, M.; Pogorelov, N.

    2017-12-01

    Since Voyager 1 crossed the heliopause into the local interstellar medium in August 2012, it has been observing nearly unmodulated low-energy Galactic cosmic rays for over 5 years and 18 AU beyond the heliopause. The angular distribution of these cosmic rays is not isotropic, showing a slight depletion at 90-degree pitch-angle to the magnetic field lines. The anisotropy was interrupted episodically by solar disturbances transmitting through the heliopause into the local interstellar medium of outer heliosheath. These observations indicate the heliosphere still affects cosmic rays in the local interstellar medium. The paper presents a theoretical analysis of the particle transport mechanisms responsible for the observed anisotropy. In order to explain the phenomenon, we argue that cosmic rays of near 90-degree pitch angles do not a quick access to the interstellar cosmic-ray source and in the meantime, they experience some loss in the outer heliosheath. Magnetic field barriers on the both sides of the observer may reduce the access to cosmic ray source, but it still requires that pitch scattering of these particles is very weak in the magnetic field of the outer heliosheath. A possible particle loss mechanism is diffusion into the heliospheric magnetic field where they get modulated by the solar wind plasma. Our model simulation will put constraints on the rates of particle scattering and cross-field diffusion in the interstellar magnetic field of the outer heliosheath.

  4. A Dual-Colour Architecture for Pump-Probe Spectroscopy of Ultrafast Magnetization Dynamics in the Sub-10-femtosecond Range.

    PubMed

    Gonçalves, C S; Silva, A S; Navas, D; Miranda, M; Silva, F; Crespo, H; Schmool, D S

    2016-03-15

    Current time-resolution-limited dynamic measurements clearly show the need for improved techniques to access processes on the sub-10-femtosecond timescale. To access this regime, we have designed and constructed a state-of-the-art time-resolved magneto-optic Kerr effect apparatus, based on a new dual-color scheme, for the measurement of ultrafast demagnetization and precessional dynamics in magnetic materials. This system can operate well below the current temporal ranges reported in the literature, which typically lie in the region of around 50 fs and above. We have used a dual-colour scheme, based on ultra broadband hollow-core fibre and chirped mirror pulse compression techniques, to obtain unprecedented sub-8-fs pump and probe pulse durations at the sample plane. To demonstrate the capabilities of this system for ultrafast demagnetization and precessional dynamics studies, we have performed measurements in a ferrimagnetic GdFeCo thin film. Our study has shown that the magnetization shows a sudden drop within the first picosecond after the pump pulse, a fast recovery (remagnetization) within a few picoseconds, followed by a clear oscillation or precession during a slower magnetization recovery. Moreover, we have experimentally confirmed for the first time that a sub-10-fs pulse is able to efficiently excite a magnetic system such as GdFeCo.

  5. Magnetically coupled flextensional transducer for wideband vibration energy harvesting: Design, modeling and experiments

    NASA Astrophysics Data System (ADS)

    Zou, Hong-Xiang; Zhang, Wen-Ming; Li, Wen-Bo; Wei, Ke-Xiang; Hu, Kai-Ming; Peng, Zhi-Ke; Meng, Guang

    2018-03-01

    The combination of nonlinear bistable and flextensional mechanisms has the advantages of wide operating frequency and high equivalent piezoelectric constant. In this paper, three magnetically coupled flextensional vibration energy harvesters (MF-VEHs) are designed from three magnetically coupled vibration systems which utilize a magnetic repulsion, two symmetrical magnetic attractions and multi-magnetic repulsions, respectively. The coupled dynamic models are developed to describe the electromechanical transitions. Simulations under harmonic excitation and random excitation are carried out to investigate the performance of the MF-VEHs with different parameters. Experimental validations of the MF-VEHs are performed under different excitation levels. The experimental results verify that the developed mathematical models can be used to accurately characterize the MF-VEHs for various magnetic coupling modes. A comparison of three MF-VEHs is provided and the results illustrate that a reasonable arrangement of multiple magnets can reduce the threshold excitation intensity and increase the harvested energy.

  6. Random walks with random velocities.

    PubMed

    Zaburdaev, Vasily; Schmiedeberg, Michael; Stark, Holger

    2008-07-01

    We consider a random walk model that takes into account the velocity distribution of random walkers. Random motion with alternating velocities is inherent to various physical and biological systems. Moreover, the velocity distribution is often the first characteristic that is experimentally accessible. Here, we derive transport equations describing the dispersal process in the model and solve them analytically. The asymptotic properties of solutions are presented in the form of a phase diagram that shows all possible scaling regimes, including superdiffusive, ballistic, and superballistic motion. The theoretical results of this work are in excellent agreement with accompanying numerical simulations.

  7. Spontaneous liquid crystal and ferromagnetic ordering of colloidal magnetic nanoplates

    DOE PAGES

    Shuai, M.; Klittnick, A.; Shen, Y.; ...

    2016-01-28

    Ferrofluids are familiar as colloidal suspensions of ferromagnetic nanoparticles in aqueous or organic solvents. The dispersed particles are randomly oriented but their moments become aligned if a magnetic field is applied, producing a variety of exotic and useful magnetomechanical effects. A longstanding interest and challenge has been to make such suspensions macroscopically ferromagnetic, that is having uniform magnetic alignment in the absence of a field. Here we report a fluid suspension of magnetic nanoplates that spontaneously aligns into an equilibrium nematic liquid crystal phase that is also macroscopically ferromagnetic. We find Its zero-field magnetization produces distinctive magnetic self-interaction effects, includingmore » liquid crystal textures of fluid block domains arranged in closed flux loops, and makes this phase highly sensitive, with it dramatically changing shape even in the Earth’s magnetic field.« less

  8. Paging memory from random access memory to backing storage in a parallel computer

    DOEpatents

    Archer, Charles J; Blocksome, Michael A; Inglett, Todd A; Ratterman, Joseph D; Smith, Brian E

    2013-05-21

    Paging memory from random access memory (`RAM`) to backing storage in a parallel computer that includes a plurality of compute nodes, including: executing a data processing application on a virtual machine operating system in a virtual machine on a first compute node; providing, by a second compute node, backing storage for the contents of RAM on the first compute node; and swapping, by the virtual machine operating system in the virtual machine on the first compute node, a page of memory from RAM on the first compute node to the backing storage on the second compute node.

  9. A Study on the Stream Cipher Embedded Magic Square of Random Access Files

    NASA Astrophysics Data System (ADS)

    Liu, Chenglian; Zhao, Jian-Ming; Rafsanjani, Marjan Kuchaki; Shen, Yijuan

    2011-09-01

    Magic square and stream cipher issues are both interesting and well-tried topics. In this paper, we are proposing a new scheme which streams cipher applications for random access files based on the magic square method. There are two thresholds required to secure our data, if using only decrypts by the stream cipher. It isn't to recovery original source. On other hand, we improve the model of cipher stream to strengthen and defend efficiently; it also was its own high speed and calculates to most parts of the key stream generator.

  10. Enhancement of Speed Margins for 16× Digital Versatile Disc-Random Access Memory

    NASA Astrophysics Data System (ADS)

    Watanabe, Koichi; Minemura, Hiroyuki; Miyamoto, Makoto; Iimura, Makoto

    2006-02-01

    We have evaluated the speed margins of write/read 16× digital versatile disc-random access memory (DVD-RAM) test discs using write strategies for 6--16× constant angular velocity (CAV) control. Our approach is to determine the writing parameters for the middle zones by interpolating the zone numbers. Using this interpolation strategy, we successfully obtained overwrite jitter values of less than 8% and bit error rates of less than 10-5 in 6--16× DVD-RAM. Moreover, we confirmed that the speed margins were ± 20% for a 6--16× CAV.

  11. Random Access Frame (RAF) System Neutral Buoyancy Evaluations

    NASA Technical Reports Server (NTRS)

    Howe, A. Scott; Polit-Casillas, Raul; Akin, David L.; McBryan, Katherine; Carlsen, Christopher

    2015-01-01

    The Random Access Frame (RAF) concept is a system for organizing internal layouts of space habitats, vehicles, and outposts. The RAF system is designed as a more efficient improvement over the current International Standard Payload Rack (ISPR) used on the International Space Station (ISS), which was originally designed to allow for swapping and resupply by the Space Shuttle. The RAF system is intended to be applied in variable gravity or microgravity environments. This paper discusses evaluations and results of testing the RAF system in a neutral buoyancy facility simulating low levels of gravity that might be encountered in a deep space environment.

  12. Advanced Cosmic-Ray Composition Experiment for Space Station (ACCESS): ACCESS Accommodation Study Report

    NASA Technical Reports Server (NTRS)

    Wilson, Thomas L. (Editor); Wefel, John P. (Editor)

    1999-01-01

    In 1994 NASA Administrator selected the first high-energy particle physics experiment for the Space Station, the Alpha Magnetic Spectrometer (AMS), to place a magnetic spectrometer in Earth orbit and search for cosmic antimatter. A natural consequence of this decision was that NASA would begin to explore cost-effective ways through which the design and implementation of AMS might benefit other promising payload experiments. The first such experiment to come forward was Advanced Cosmic-Ray Composition Experiment for Space Station (ACCESS) in 1996. It was proposed as a new mission concept in space physics to attach a cosmic-ray experiment of weight, volume, and geometry similar to the AMS on the International Space Station (ISS), and replace the latter as its successor when the AMS is returned to Earth. This was to be an extension of NASA's suborbital balloon program, with balloon payloads serving as the precursor flights and heritage for ACCESS. The balloon programs have always been a cost-effective NASA resource since the particle physics instrumentation for balloon and space applications are directly related. The next step was to expand the process, pooling together expertise from various NASA centers and universities while opening up definition of the ACCESS science goals to the international community through the standard practice of peer review. This process is still ongoing, and the accommodation study presented here will discuss the baseline definition of ACCESS as we understand it today.

  13. Influence of Terrestrial Weathering on the Magnetic Record of a LL Chondrite

    NASA Astrophysics Data System (ADS)

    Kohout, T.; Kletetschka, G.; Wasilewski, P.

    2001-12-01

    The origin of our solar system may have been accompanied by transient energetic events capable of magnetizing the materials from which the solid bodies in the solar system formed. The magnetic field associated with some of some of these events should have been recorded by the magnetic mineralogy contained within meteorites. To extract this information from meteorites many noise components must be carefully eliminated. The fusion crust has long been established as restricted to a thin layer on the surface of meteorite. Magnetic screening of the fusion crust that relates to Murchison meteorite indicates that during the entry and landing at least 6 mm thick layer is affected by terrestrial TRM acquisition. Many of the meteorite finds have long term residence in the terrestrial oxidized environment. This weathering is the subject of this study. The meteorite in question landed in the Libya stony desert and has obvious surface weathering that can be referred to as desert varnish. The consequent iron oxide mineralization introduced very stable origin of very stable chemical remanent magnetization. The magnetic remanence in fragments without the desert varnish is between 20 - 50 % of the oxidized ones. The orientation of this CRM appears to be random indicating that the sample may have rotated during the long period of aeolian transport and varnish formation. Magnetization of the white matrix samples (20 - 50 % of weathered ones) is thermally more stable and also randomly oriented. The range of NRM/SIRM values for both mineralogies varies between 10-2 and 10-3. Acknowledgements: This work would not be possible without help of following people: Jakub Haloda, Petr Jakes, Marcela Bukovanska, Petr Pruner, Vladimir Kohout, Libuse Kohoutova, Vladimir Kohout, Olga Kohoutova.

  14. Random anisotropy model approach on ion beam sputtered Co 20Cu 80 granular alloy

    NASA Astrophysics Data System (ADS)

    Errahmani, H.; Hassanaı̈n, N.; Berrada, A.; Abid, M.; Lassri, H.; Schmerber, G.; Dinia, A.

    2002-03-01

    The Co 20Cu 80 granular film has been elaborated using ion beam sputtering technique. The magnetic properties of the sample were studied in the temperature range 5-300 K at H⩽50 kOe. From the thermomagnetisation curve, which is found to obey to the Bloch law, we have extracted the spin wave stiffness constant D and the exchange constant A. The magnetic experimental results have been interpreted in the framework of random anisotropy model. We have determined the local anisotropy constant KL and the local correlation length of anisotropy axis Ra, which is compared to the experimental grains size obtained by transmission electronic microscopy.

  15. Brief Report: Randomized Test of the Efficacy of Picture Exchange Communication System on Highly Generalized Picture Exchanges in Children with ASD

    ERIC Educational Resources Information Center

    Yoder, Paul J.; Lieberman, Rebecca G.

    2010-01-01

    A randomized control trial comparing two social-communication interventions in young children with autism examined far-transfer of the use of picture exchange to communicate. Thirty-six children were randomly assigned to one of two treatment conditions, one of which was the Picture Exchange Communication System (PECS). All children had access to…

  16. Nimbus 6 Random Access Measurement System applications experiments

    NASA Technical Reports Server (NTRS)

    Cote, C. E. (Editor); Taylor, R. (Editor); Gilbert, E. (Editor)

    1982-01-01

    The advantages of a technique in which data collection platforms randomly transmit signal to a polar orbiting satellite, thus eliminating satellite interrogation are demonstrated in investigations of the atmosphere; oceanographic parameters; Arctic regions and ice conditions; navigation and position location; and data buoy development.

  17. Deviation from the law of energy equipartition in a small dynamic-random-access memory

    NASA Astrophysics Data System (ADS)

    Carles, Pierre-Alix; Nishiguchi, Katsuhiko; Fujiwara, Akira

    2015-06-01

    A small dynamic-random-access memory (DRAM) coupled with a high charge sensitivity electrometer based on a silicon field-effect transistor is used to study the law of equipartition of energy. By statistically analyzing the movement of single electrons in the DRAM at various temperature and voltage conditions in thermal equilibrium, we are able to observe a behavior that differs from what is predicted by the law of equipartition energy: when the charging energy of the capacitor of the DRAM is comparable to or smaller than the thermal energy kBT/2, random electron motion is ruled perfectly by thermal energy; on the other hand, when the charging energy becomes higher in relation to the thermal energy kBT/2, random electron motion is suppressed which indicates a deviation from the law of equipartition of energy. Since the law of equipartition is analyzed using the DRAM, one of the most familiar devices, we believe that our results are perfectly universal among all electronic devices.

  18. Investigating the magnetic inclination angle distribution of γ-ray-loud radio pulsars

    NASA Astrophysics Data System (ADS)

    Rookyard, S. C.; Weltevrede, P.; Johnston, S.

    2015-02-01

    Several studies have shown the distribution of pulsars' magnetic inclination angles to be skewed towards low values compared with the distribution expected if the rotation and magnetic axes are placed randomly on the star. Here, we focus on a sample of 28 γ-ray-detected pulsars using data taken as part of the Parkes telescope's FERMI timing program. In doing so, we find a preference in the sample for low magnetic inclination angles, α, in stark contrast to both the expectation that the magnetic and rotation axes are orientated randomly at the birth of the pulsar and to γ-ray-emission-model-based expected biases. In this paper, after exploring potential explanations, we conclude that there are two possible causes of this preference, namely that low α values are intrinsic to the sample, or that the emission regions extend outside what is traditionally thought to be the open-field-line region in a way which is dependent on the magnetic inclination. Each possibility is expected to have important consequences, ranging from supernova physics to population studies of pulsars and considerations of the radio beaming fraction. We also present a simple conversion scheme between the observed and intrinsic magnetic inclinations which is valid under the assumption that the observed skew is not intrinsic and which can be applied to all existing measurements. We argue that extending the active-field-line region will help to resolve the existing tension between emission geometries derived from radio polarization measurements and those required to model γ-ray light curves.

  19. Large Quantum Probability Backflow and the Azimuthal Angle-Angular Momentum Uncertainty Relation for an Electron in a Constant Magnetic Field

    ERIC Educational Resources Information Center

    Strange, P.

    2012-01-01

    In this paper we demonstrate a surprising aspect of quantum mechanics that is accessible to an undergraduate student. We discuss probability backflow for an electron in a constant magnetic field. It is shown that even for a wavepacket composed entirely of states with negative angular momentum the effective angular momentum can take on positive…

  20. A perspective on slow-relaxing molecular magnets built from rare-earths and nitronyl-nitroxide building blocks (invited)

    NASA Astrophysics Data System (ADS)

    Bogani, Lapo

    2011-04-01

    We offer a perspective, accessible to both chemists and physicists, of recent developments in the synthesis and characterization of molecular magnetic materials based on rare-earths and nitronyl-nitroxide radicals. We show both the rationale of the synthetic strategies and the observed behaviors. We highlight the relevance of these findings for synthetic chemists, material scientists, and physicists.

Top