Fabrication and properties of Nd(Tb,Dy)Co/Cr films with perpendicular magnetic anisotropy
NASA Astrophysics Data System (ADS)
Cheng, Weiming; Miao, Xiangshui; Yan, Junbing; Cheng, Xiaomin
2009-08-01
Light rare earth-heavy rare earth-transition metal films (LRE-HRE-TM)have large saturation magnetization (Ms) and are the promising media for hybrid recording. In this paper, Nd(Tb,Dy)Co/Cr films with perpendicular magnetic anisotropy were successfully fabricated onto glass substrate by RF magnetron sputtering and the effects of sputtering technology parameters and Nd substitution for HRE atoms on the magnetic properties were investigated. It was found that when the sputtering power and sputtering time are 250W and 4min, respectively, the magnetic properties of Nd(Tb,Dy)Co/Cr films obtain optimization, perpendicular coercivity, Ms and remanence square ratio(S) of NdTbCo/Cr film reach 3.8kOe, 247emu/cm3 and 0.801, respectively. With the increasing of Nd concentration, Ms increases, while the coercivity (Hc)and the temperature stability of magnetic properties decrease distinctly. These results can be explained by the ferri-magnetic structure of the RE-TM alloy.
SP-grain production during thermal demagnetization of some Chinese loess/palaeosol
NASA Astrophysics Data System (ADS)
Wang, Ronghua; Løvlie, Reidar
2008-02-01
Progressive thermal demagnetization of natural samples to above 300 °C may cause significant alterations of magnetic mineral phases. Such changes are commonly monitored by magnetic susceptibility (MS) determinations at every demagnetization step. In an attempt to characterize in more detail alteration products created during thermal demagnetization of some Chinese loess/palaeosols (L1/S1), MS was measured at both room temperature (MS293K) and at liquid Nitrogen temperature (MS77K) between each demagnetization step. We have used the difference between MS77K and MS293K (temperature dependent susceptibility, kTD = MS293K - MS77K) to monitor production of superparamagnetic (SP) magnetic grains. kTD is a function of; (1) paramagnetic susceptibility according to the Curie law (k ~ 1/T) that predicts a theoretical 3.83 times increase in MS at 77K. (2) SP grains at 293 K that passes into the single-domain (SD) state on cooling to 77 K causing a dramatic reduction in MS77K. (3) magnetite grains exhibiting magnetic changes when passing through the Verwey transition at 120 K will also reduce MS77K. We observe a linear relationship between frequency-dependent MS (kFD) and temperature dependent susceptibility (kTD) indicating that SP-SD blocking of magnetite may be the dominant factor of MS change during cooling. High values of kTD indicates high SP concentrations, and an increase of kTD with increasing demagnetization temperature is mainly attributed to the production of SP grains since the amount of magnetite exhibiting changes in MS at the Verwey-transition is unlikely to increase during heating of loess/palaeosol to 600 °C in air. This interpretation is also based on results from Zero Field Heating IRM77K(1T), Zero Field Cooling of IRM77K(1T) and short-time (100 s) viscous decay of IRM500mT. Our findings suggest that SP-grains are produced continuously in both loess and palaeosol with thermal treatment, and that SP-production in palaeosol apparently commence at the `surprisingly' low temperature of around 200 °C.
NASA Astrophysics Data System (ADS)
Samanifar, S.; Alikhani, M.; Almasi Kashi, M.; Ramazani, A.; Montazer, A. H.
2017-05-01
Nanoscale magnetic alloy wires are being actively investigated, providing fundamental insights into tuning properties in magnetic data storage and processing technologies. However, previous studies give trivial information about the crossover angle of magnetization reversal process in alloy nanowires (NWs). Here, magnetic alloy NW arrays with different compositions, composed of Fe, Co and Ni have been electrochemically deposited into hard-anodic aluminum oxide templates with a pore diameter of approximately 150 nm. Under optimized conditions of alumina barrier layer and deposition bath concentrations, the resulting alloy NWs with aspect ratio and saturation magnetization (Ms) up to 550 and 1900 emu cm-3, respectively, are systematically investigated in terms of composition, crystalline structure and magnetic properties. Using angular dependence of coercivity extracted from hysteresis loops, the reversal processes are evaluated, indicating non-monotonic behavior. The crossover angle (θc) is found to depend on NW length and Ms. At a constant Ms, increasing NW length decreases θc, thereby decreasing the involvement of vortex mode during the magnetization reversal process. On the other hand, decreasing Ms decreases θc in large aspect ratio (>300) alloy NWs. Phenomenologically, it is newly found that increasing Ni content in the composition decreases θc. The angular first-order reversal curve (AFORC) measurements including the irreversibility of magnetization are also investigated to gain a more detailed insight into θc.
Towards a Decentralized Magnetic Indoor Positioning System
Kasmi, Zakaria; Norrdine, Abdelmoumen; Blankenbach, Jörg
2015-01-01
Decentralized magnetic indoor localization is a sophisticated method for processing sampled magnetic data directly on a mobile station (MS), thereby decreasing or even avoiding the need for communication with the base station. In contrast to central-oriented positioning systems, which transmit raw data to a base station, decentralized indoor localization pushes application-level knowledge into the MS. A decentralized position solution has thus a strong feasibility to increase energy efficiency and to prolong the lifetime of the MS. In this article, we present a complete architecture and an implementation for a decentralized positioning system. Furthermore, we introduce a technique for the synchronization of the observed magnetic field on the MS with the artificially-generated magnetic field from the coils. Based on real-time clocks (RTCs) and a preemptive operating system, this method allows a stand-alone control of the coils and a proper assignment of the measured magnetic fields on the MS. A stand-alone control and synchronization of the coils and the MS have an exceptional potential to implement a positioning system without the need for wired or wireless communication and enable a deployment of applications for rescue scenarios, like localization of miners or firefighters. PMID:26690145
Towards a Decentralized Magnetic Indoor Positioning System.
Kasmi, Zakaria; Norrdine, Abdelmoumen; Blankenbach, Jörg
2015-12-04
Decentralized magnetic indoor localization is a sophisticated method for processing sampled magnetic data directly on a mobile station (MS), thereby decreasing or even avoiding the need for communication with the base station. In contrast to central-oriented positioning systems, which transmit raw data to a base station, decentralized indoor localization pushes application-level knowledge into the MS. A decentralized position solution has thus a strong feasibility to increase energy efficiency and to prolong the lifetime of the MS. In this article, we present a complete architecture and an implementation for a decentralized positioning system. Furthermore, we introduce a technique for the synchronization of the observed magnetic field on the MS with the artificially-generated magnetic field from the coils. Based on real-time clocks (RTCs) and a preemptive operating system, this method allows a stand-alone control of the coils and a proper assignment of the measured magnetic fields on the MS. A stand-alone control and synchronization of the coils and the MS have an exceptional potential to implement a positioning system without the need for wired or wireless communication and enable a deployment of applications for rescue scenarios, like localization of miners or firefighters.
MagR Alone Is Insufficient to Confer Cellular Calcium Responses to Magnetic Stimulation
Pang, Keliang; You, He; Chen, Yanbo; Chu, Pengcheng; Hu, Meiqin; Shen, Jianying; Guo, Wei; Xie, Can; Lu, Bai
2017-01-01
Magnetic manipulation of cell activity offers advantages over optical manipulation but an ideal tool remains elusive. The MagR protein was found through its interaction with cryptochrome (Cry) and the protein in solution appeared to respond to magnetic stimulation (MS). After we initiated an investigation on the specific role of MagR in cellular response to MS, a subsequent study claimed that MagR expression alone could achieve cellular activation by MS. Here we report that despite systematically testing different ways of measuring intracellular calcium and different MS protocols, it was not possible to detect any cellular or neuronal responses to MS in MagR-expressing HEK cells or primary neurons from the dorsal root ganglion and the hippocampus. By contrast, in neurons co-expressing MagR and channelrhodopin, optical but not MS increased calcium influx in hippocampal neurons. Our results indicate that MagR alone is not sufficient to confer cellular magnetic responses. PMID:28360843
NASA Astrophysics Data System (ADS)
Morgan, D. P.
2017-01-01
I present a study of close white dwarf (WD) and M dwarf (dM) binary systems (WD+dM) to examine the effects that close companions have on magnetic field generation in dMs. Using the Sloan Digital Sky Survey (SDSS) Data Release 8 spectroscopic database, I constructed a sample of 1756 WD+dM high-quality pairs. I show that early-type dMs (
Noncollinear spin structure in SmxTb1-x[Cr(CN)6]•4H2O having orthogonal single-ion anisotropies
NASA Astrophysics Data System (ADS)
Hozumi, Toshiya; Hashimoto, Kazuhito; Ohkoshi, Shin-Ichi
2006-03-01
A series of SmxIIITb1-xIII[CrIII(CN)6]•4H2O magnets, in which SmIII and TbIII have different magnetic single-ion anisotropies, was prepared. Magnetic ordering temperatures (Tc) decreased from 12.0K (x=0) to 7.4K (x=0.55) and then increased to 10.2K (x=1) with increasing x . The magnetization (Ms) values at 5K gradually decreased from 3.0μB (x=0) to 1.6μB (x=1) . These trends of experimental Tc and Ms values suggest that the present series takes a noncollinear spin structure, in which the directions of the SmIII and TbIII sublattice magnetizations are perpendicular, from the analysis of the molecular-field model.
Enhancement of MS2D Bartington point measurement of soil magnetic susceptibility
NASA Astrophysics Data System (ADS)
Fabijańczyk, Piotr; Zawadzki, Jarosław
2015-04-01
Field magnetometry is fast method used to assess the potential soil pollution. The most popular device used to measure the soil magnetic susceptibility on the soil surface is a MS2D Bartington. Single reading using MS2D device of soil magnetic susceptibility is low time-consuming but often characterized by considerable errors related to the instrument or environmental and lithogenic factors. Typically, in order to calculate the reliable average value of soil magnetic susceptibility, a series of MS2D readings is performed in the sample point. As it was analyzed previously, such methodology makes it possible to significantly reduce the nugget effect of the variograms of soil magnetic susceptibility that is related to the micro-scale variance and measurement errors. The goal of this study was to optimize the process of taking a series of MS2D readings, whose average value constitutes a single measurement, in order to take into account micro-scale variations of soil magnetic susceptibility in proper determination of this parameter. This was done using statistical and geostatistical analyses. The analyses were performed using field MS2D measurements that were carried out in the study area located in the direct vicinity of the Katowice agglomeration. At 150 sample points 10 MS2D readings of soil magnetic susceptibility were taken. Using this data set, series of experimental variograms were calculated and modeled. Firstly, using single random MS2D reading for each sample point, and next using the data set increased by adding one more MS2D reading, until their number reached 10. The parameters of variogram: nugget effect, sill and range of correlation were used to determine the most suitable number of MS2D readings at sample point. The distributions of soil magnetic susceptibility at sample point were also analyzed in order to determine adequate number of readings enabling to calculate reliable average soil magnetic susceptibility. The research leading to these results has received funding from the Polish-Norwegian Research Programme operated by the National Centre for Research and Development under the Norwegian Financial Mechanism 2009-2014 in the frame of Project IMPACT - Contract No Pol-Nor/199338/45/2013. References: Zawadzki J., Magiera T., Fabijańczyk P., 2007. The influence of forest stand and organic horizon development on soil surface measurement of magnetic susceptibility. Polish Journal of Soil Science, XL(2), 113-124 Zawadzki J., Fabijańczyk P., Magiera T., Strzyszcz Z., 2010. Study of litter influence on magnetic susceptibility measurements of urban forest topsoils using the MS2D sensor. Environmental Earth Sciences, 61(2), 223-230.
Nathoo, Nabeela; Yong, V. Wee; Dunn, Jeff F.
2014-01-01
There are exciting new advances in multiple sclerosis (MS) resulting in a growing understanding of both the complexity of the disorder and the relative involvement of grey matter, white matter and inflammation. Increasing need for preclinical imaging is anticipated, as animal models provide insights into the pathophysiology of the disease. Magnetic resonance (MR) is the key imaging tool used to diagnose and to monitor disease progression in MS, and thus will be a cornerstone for future research. Although gadolinium-enhancing and T2 lesions on MRI have been useful for detecting MS pathology, they are not correlative of disability. Therefore, new MRI methods are needed. Such methods require validation in animal models. The increasing necessity for MRI of animal models makes it critical and timely to understand what research has been conducted in this area and what potential there is for use of MRI in preclinical models of MS. Here, we provide a review of MRI and magnetic resonance spectroscopy (MRS) studies that have been carried out in animal models of MS that focus on pathology. We compare the MRI phenotypes of animals and patients and provide advice on how best to use animal MR studies to increase our understanding of the linkages between MR and pathology in patients. This review describes how MRI studies of animal models have been, and will continue to be, used in the ongoing effort to understand MS. PMID:24936425
Magnetic properties of black mud turbidites from ODP Leg 116, distal Bengal Fan
DOE Office of Scientific and Technical Information (OSTI.GOV)
Sager, W.W.; Hall, S.A.
1991-03-01
Turbidites from the distal Bengal Fan cored on ODP Leg 116 showed large magnetic susceptibility (MS) variations. MS peaks were traced to individual turbidites, the most magnetic being dark gray mud turbidites. In addition to large MS values, the turbidites stand out from surrounding layers because of high NRMs, ARMs, SIRMs, and ratios of ARM and SIRM to susceptibility. Alternating field and thermal demagnetization properties and IRM acquisition curves suggest titanomagnetite grains as the primary magnetic mineral with some amount of hematite present. These properties are similar to those of Deccan flood basalts and suggest this formation as a sourcemore » of magnetic grains. Magnetic granulometry tests implied that the magnetic particles behave as single-domain and pseudo single-domain grains. They also indicate that the large susceptibility peaks result from a tenfold increase in the concentration of titanomagnetite grains. Electron microscope, EDX, and SIRM analyses revealed detrital titanomagnetites with typical sizes around 8-10 {mu}m, but as large as 20-25 {mu}. These are probably the dominant magnetic grains in the black mud turbidites; however, ARM and susceptibility frequency-dependence suggested that there may also be a submicrometer fraction present. Most of the observed titanomagnetite grains are tabular and some display exsolution lamellae, accounting for the pseudo single-domain behavior despite their moderate sizes. Variations in individual MS peak shapes may reflect sedimentological factors such as current velocity changes. Moreover, downhole variations in the amplitudes of turbidite MS peaks suggest a tectonic or environmental influence.« less
Wang, J.-S.; Grimley, D.A.; Xu, C.; Dawson, J.O.
2008-01-01
Flooded, saturated or poorly drained soils are frequently anaerobic, leading to dissolution of the strongly magnetic minerals, magnetite and maghemite, and a corresponding decrease in soil magnetic susceptibility (MS). In this study of five temperate deciduous forests in east-central Illinois, USA, mean surface soil MS was significantly higher adjacent to upland tree species (31 ?? 10-5 SI) than adjacent to floodplain or lowland tree species (17 ?? 10-5 SI), when comparing regional soils with similar parent material of loessal silt. Although the sites differ in average soil MS for each tree species, the relative order of soil MS means for associated tree species at different locations is similar. Lowland tree species, Celtis occidentalis L., Ulmus americana L., Acer saccharinum L., Carya laciniosa (Michx. f.) Loud., and Fraxinus pennsylvanica Marsh. were associated with the lowest measured soil MS mean values overall and at each site. Tree species' flood tolerance rankings increased significantly, as soil MS values declined, the published rankings having significant correlations with soil MS values for the same species groups. The three published classifications of tree species' flood tolerance were significantly correlated with associated soil MS values at all sites, but most strongly at Allerton Park, the site with the widest range of soil drainage classes and MS values. Using soil MS measurements in forests with soil parent material containing similar initial levels of strongly magnetic minerals can provide a simple, rapid and quantitative method to classify soils according to hydric regimes, including dry conditions, and associated plant composition. Soil MS values thus have the capacity to quantify the continuum of hydric tolerances of tree species and guide tree species selection for reforestation. ?? 2007 Elsevier B.V. All rights reserved.
Yield cultivation of magnetotactic bacteria and magnetosomes: A review.
Ali, Imran; Peng, Changsheng; Khan, Zahid M; Naz, Iffat
2017-08-01
Magnetotactic bacteria (MTB) have started to be employed for the biosynthesis of magnetic nanoparticles, due to the rapidly increasing demand for nanoparticles in biomedical, biotechnology and environmental protection. MBT are the group of prokaryotes that have the ability to produce bio-magnetic minerals or bio-magnetic crystals of either magnetite (Fe 3 O 4 ) or greigite (Fe 3 S 4 ) in numerous shapes and size ranges, known as magnetosomes (MS). MS compel MTB to respond to the applied external magnetic field. However, it is extremely difficult to grow MTB and produce high yield of MS under artificial environmental conditions, thus creating a major hurdle to relocate MTB technology from laboratory scale to industrial or commercial level. Therefore, to best of our knowledge this review is the first attempt to highlight existing research developments about the laboratory scale and mass production of MS by MTB. Moreover, the optimum culture media and environmental conditions used for the cultivation of MTB were also considered. Finally, future research is encouraged for the improvement of MS yield which will result in the development of advanced nanotechnology/magnetotechnology. © 2017 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.
Genova, Helen M.; Rajagopalan, Venkateswaran; DeLuca, John; Das, Abhijit; Binder, Allison; Arjunan, Aparna; Chiaravalloti, Nancy; Wylie, Glenn
2013-01-01
The present study investigated the neural correlates of cognitive fatigue in Multiple Sclerosis (MS), looking specifically at the relationship between self-reported fatigue and objective measures of cognitive fatigue. In Experiment 1, functional magnetic resonance imaging (fMRI) was used to examine where in the brain BOLD activity covaried with “state” fatigue, assessed during performance of a task designed to induce cognitive fatigue while in the scanner. In Experiment 2, diffusion tensor imaging (DTI) was used to examine where in the brain white matter damage correlated with increased “trait” fatigue in individuals with MS, assessed by the Fatigue Severity Scale (FSS) completed outside the scanning session. During the cognitively fatiguing task, the MS group had increased brain activity associated with fatigue in the caudate as compared with HCs. DTI findings revealed that reduced fractional anisotropy in the anterior internal capsule was associated with increased self-reported fatigue on the FSS. Results are discussed in terms of identifying a “fatigue-network” in MS. PMID:24223850
Genova, Helen M; Rajagopalan, Venkateswaran; Deluca, John; Das, Abhijit; Binder, Allison; Arjunan, Aparna; Chiaravalloti, Nancy; Wylie, Glenn
2013-01-01
The present study investigated the neural correlates of cognitive fatigue in Multiple Sclerosis (MS), looking specifically at the relationship between self-reported fatigue and objective measures of cognitive fatigue. In Experiment 1, functional magnetic resonance imaging (fMRI) was used to examine where in the brain BOLD activity covaried with "state" fatigue, assessed during performance of a task designed to induce cognitive fatigue while in the scanner. In Experiment 2, diffusion tensor imaging (DTI) was used to examine where in the brain white matter damage correlated with increased "trait" fatigue in individuals with MS, assessed by the Fatigue Severity Scale (FSS) completed outside the scanning session. During the cognitively fatiguing task, the MS group had increased brain activity associated with fatigue in the caudate as compared with HCs. DTI findings revealed that reduced fractional anisotropy in the anterior internal capsule was associated with increased self-reported fatigue on the FSS. Results are discussed in terms of identifying a "fatigue-network" in MS.
Effect of substrate temperature on magnetic properties of MnFe2O4 thin films
NASA Astrophysics Data System (ADS)
Rajagiri, Prabhu; Sahu, B. N.; Venkataramani, N.; Prasad, Shiva; Krishnan, R.
2018-05-01
MnFe2O4 thin films were pulsed laser deposited on to quartz substrate from room temperature (RT) to 650 °C in a pure argon environment. Temperature dependence of spontaneous magnetization (4πMS) was measured on these films from 10 K to 350 K using a vibrating sample magnetometer. Ferromagnetic resonance (FMR) study was also carried out at 300 K. The exchange stiffness constant (D) values were obtained by fitting the 4πMS data to the Bloch's equation. The D values of the films thus found decreases while the 4πMS value increases, though non-monotonically, with the increase in TS and tend to reach bulk values at TS = 650 °C. The variation in D and 4πMS values of the films are explained based on the degree of inversion and oxidation state of cations in thin films.
Non-Maxwellian effects in magnetosonic solitons
NASA Astrophysics Data System (ADS)
Pokhotelov, O. A.; Balikhin, M. A.; Onishchenko, O. G.; Walker, S. N.
2007-12-01
The role of non-Maxwellian effects on magnetosonic (MS) solitons propagating perpendicular to the external magnetic field in high- β plasmas is analysed. It is shown that they can exist in the form of either humps or holes in the magnetic field in which the field is either increased or decreased relative to the background magnetic field. The shape of the solitary structure depends upon both the form of the ion velocity distribution function and the wave dispersion. A nonlinear equation describing the propagation of MS solitons in high- β plasmas with an arbitrary particle velocity distribution function is derived. It is shown that for Maxwellian and bi-Maxwellian plasmas MS solitons can only exist in the form of the magnetic humps. The same is true for plasmas possessing either a kappa distribution or Kennel-Ashour-Abdalla equilibria. However, plasmas with a ring type ion velocity distribution or a Dory-Guest-Harris distribution with large loss-cone index can support the formation of magnetic holes. The theoretical results obtained are then compared with recent satellite observations.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Ouyang, Gaoyuan; Jensen, Brandt; Tang, Wei
Here, Fe-Si electric steel is the most widely used soft magnetic material in electric machines and transformers. Increasing the silicon content from 3.2 wt.% to 6.5 wt.% brings about large improvement in the magnetic and electrical properties. However, 6.5 wt.% silicon steel is inherited with brittleness owing to the formation of B2 and D0 3 ordered phase. To obtain ductility in Fe-6.5wt.% silicon steel, the ordered phase has to be bypassed with methods like rapid cooling. In present paper, the effect of cooling rate on magnetic and mechanical properties of Fe-6.5wt.% silicon steel is studied by tuning the wheel speedmore » during melt spinning process. The cooling rate significantly alters the ordering and microstructure, and thus the mechanical and magnetic properties. X-ray diffraction data shows that D0 3 ordering was fully suppressed at high wheel speeds but starts to nucleate at 10m/s and below, which correlates with the increase of Young’s modulus towards low wheel speeds as tested by nanoindentation. The grain sizes of the ribbons on the wheel side decrease with increasing wheel speeds, ranging from ~100 μm at 1m/s to ~8 μm at 30m/s, which lead to changes in coercivity.« less
Ouyang, Gaoyuan; Jensen, Brandt; Tang, Wei; ...
2017-12-19
Here, Fe-Si electric steel is the most widely used soft magnetic material in electric machines and transformers. Increasing the silicon content from 3.2 wt.% to 6.5 wt.% brings about large improvement in the magnetic and electrical properties. However, 6.5 wt.% silicon steel is inherited with brittleness owing to the formation of B2 and D0 3 ordered phase. To obtain ductility in Fe-6.5wt.% silicon steel, the ordered phase has to be bypassed with methods like rapid cooling. In present paper, the effect of cooling rate on magnetic and mechanical properties of Fe-6.5wt.% silicon steel is studied by tuning the wheel speedmore » during melt spinning process. The cooling rate significantly alters the ordering and microstructure, and thus the mechanical and magnetic properties. X-ray diffraction data shows that D0 3 ordering was fully suppressed at high wheel speeds but starts to nucleate at 10m/s and below, which correlates with the increase of Young’s modulus towards low wheel speeds as tested by nanoindentation. The grain sizes of the ribbons on the wheel side decrease with increasing wheel speeds, ranging from ~100 μm at 1m/s to ~8 μm at 30m/s, which lead to changes in coercivity.« less
NASA Astrophysics Data System (ADS)
Ouyang, Gaoyuan; Jensen, Brandt; Tang, Wei; Dennis, Kevin; Macziewski, Chad; Thimmaiah, Srinivasa; Liang, Yongfeng; Cui, Jun
2018-05-01
Fe-Si electric steel is the most widely used soft magnetic material in electric machines and transformers. Increasing the silicon content from 3.2 wt.% to 6.5 wt.% brings about large improvement in the magnetic and electrical properties. However, 6.5 wt.% silicon steel is inherited with brittleness owing to the formation of B2 and D03 ordered phase. To obtain ductility in Fe-6.5wt.% silicon steel, the ordered phase has to be bypassed with methods like rapid cooling. In present paper, the effect of cooling rate on magnetic and mechanical properties of Fe-6.5wt.% silicon steel is studied by tuning the wheel speed during melt spinning process. The cooling rate significantly alters the ordering and microstructure, and thus the mechanical and magnetic properties. X-ray diffraction data shows that D03 ordering was fully suppressed at high wheel speeds but starts to nucleate at 10m/s and below, which correlates with the increase of Young's modulus towards low wheel speeds as tested by nanoindentation. The grain sizes of the ribbons on the wheel side decrease with increasing wheel speeds, ranging from ˜100 μm at 1m/s to ˜8 μm at 30m/s, which lead to changes in coercivity.
Magnetic properties of CeFe11-xCoxTi with ThMn12 structure
DOE Office of Scientific and Technical Information (OSTI.GOV)
Zhou, C; Pinkerton, FE; Herbst, JF
2014-05-07
A series of novel alloys CeFe11-xCoxTi (0 <= x <= 11) with ThMn12 structure has been successfully prepared by melt-spinning. The Curie temperature T-c increases with Co content x, reaching a maximum of 689 degrees C at x = 9 and declining to 664 degrees C at complete Co filling (x = 11). The room temperature saturation magnetization 4 pi M-s and magnetocrystalline anisotropy H-a have been estimated by fitting the first quadrant demagnetization curve with the Stoner-Wohlfarth model. 4 pi M-s first increases with increasing Co up to x = 3, then decrease. H-a has a complex dependence onmore » Co content, which is indicative of a change in the easy magnetization direction from axis to plane and back as the Co content increases. (C) 2014 AIP Publishing LLC.« less
NASA Astrophysics Data System (ADS)
Yang, Yujie; Wang, Fanhou; Huang, Duohui; Shao, Juxiang; Tang, Jin; Ur Rehman, Khalid Mehmood; Wu, Zhen
2018-04-01
Sn-Mg co-substituted M-type SrCaLa hexaferrites Sr0.5Ca0.2La0.3Fe12.0-2x(SnMg)xO19 (0.0 ≤ x ≤ 0.5) have been synthesized by ball milling and calcining. The results of X-ray diffraction show that a single magnetoplumbite phase is exhibited in all the samples and no impurity phase is observed in the structure. Lattice constants (c and a) increase with increasing Sn-Mg content (x) from 0.0 to 0.5. Platelet like structure exhibited by FE-SEM micrographs confirms the hexagonal structure of the synthesized samples. The saturation magnetization (Ms) first increases with increasing SnMg content (x) from 0.0 to 0.1, and then decreases when Sn-Mg content (x) ≥ 0.1. The remanent magnetization (Mr), Mr/Ms ratio, coercivity (Hc), magnetic anisotropy field (Ha) and first anisotropy constant (K1) decrease with increasing Sn-Mg content (x) from 0.0 to 0.5.
Bergsland, Niels; Schweser, Ferdinand; Dwyer, Michael G; Weinstock-Guttman, Bianca; Benedict, Ralph H B; Zivadinov, Robert
2018-06-19
Thalamic white matter (WM) injury in multiple sclerosis (MS) remains relatively poorly understood. Combining multiple imaging modalities, sensitive to different tissue properties, may aid in further characterizing thalamic damage. Forty-five MS patients and 17 demographically-matched healthy controls (HC) were scanned with 3T MRI to obtain quantitative measures of diffusivity and magnetic susceptibility. Participants underwent cognitive evaluation with the Brief International Cognitive Assessment for Multiple Sclerosis battery. Tract-based spatial statistics identified thalamic WM. Non-parametric combination (NPC) analysis was used to perform joint inference on fractional anisotropy (FA), mean diffusivity (MD) and magnetic susceptibility measures. The association of surrounding WM lesions and thalamic WM pathology was investigated with lesion probability mapping. Compared to HCs, the greatest extent of thalamic WM damage was reflected by the combination of increased MD and decreased magnetic susceptibility (63.0% of thalamic WM, peak p = .001). Controlling for thalamic volume resulted in decreased FA and magnetic susceptibility (34.1%, peak p = .004) as showing the greatest extent. In MS patients, the most widespread association with information processing speed was found with the combination of MD and magnetic susceptibility (67.6%, peak p = .0005), although this was not evident after controlling for thalamic volume. For memory measures, MD alone yielded the most widespread associations (45.9%, peak p = .012 or 76.7%, peak p = .001), even after considering thalamic volume, albeit with smaller percentages. White matter lesions were related to decreased FA (peak p = .0063) and increased MD (peak p = .007), but not magnetic susceptibility, of thalamic WM. Our study highlights the complex nature of thalamic pathology in MS. © 2018 Wiley Periodicals, Inc.
Tinschert, K; Lang, R; Mäder, J; Rossbach, J; Spädtke, P; Komorowski, P; Meyer-Reumers, M; Krischel, D; Fischer, B; Ciavola, G; Gammino, S; Celona, L
2012-02-01
The production of intense beams of heavy ions with electron cyclotron resonance ion sources (ECRIS) is an important request at many accelerators. According to the ECR condition and considering semi-empirical scaling laws, it is essential to increase the microwave frequency together with the magnetic flux density of the ECRIS magnet system. A useful frequency of 28 GHz, therefore, requires magnetic flux densities above 2.2 T implying the use of superconducting magnets. A cooperation of European institutions initiated a project to build a multipurpose superconducting ECRIS (MS-ECRIS) in order to achieve an increase of the performances in the order of a factor of ten. After a first design of the superconducting magnet system for the MS-ECRIS, the respective cold testing of the built magnet system reveals a lack of mechanical performance due to the strong interaction of the magnetic field of the three solenoids with the sextupole field and the magnetization of the magnetic iron collar. Comprehensive structural analysis, magnetic field calculations, and calculations of the force pattern confirm thereafter these strong interactions, especially of the iron collar with the solenoidal fields. The investigations on the structural analysis as well as suggestions for a possible mechanical design solution are given.
Modelling magnetic anisotropy of single-chain magnets in |d/J| ≥ 1 regime
NASA Astrophysics Data System (ADS)
Haldar, Sumit; Raghunathan, Rajamani; Sutter, Jean-Pascal; Ramasesha, S.
2017-11-01
Single-molecule magnets (SMMs) with single-ion anisotropies comparable to exchange interactions J between spins have recently been synthesised. Here, we provide theoretical insights into the magnetism of such systems. We study spin chains with site-spins, s = 1, 3/2 and 2 and strength of on-site anisotropy comparable to the exchange constants between the spins. We find that large on-site anisotropies lead to crossing of the states with different MS values in the same spin manifold to which they belong in the absence of anisotropy. When on-site anisotropy is increased further, we also find that the MS states of the higher energy spin states descend below the MS states of the ground spin manifold. Giant spin in this limit is no longer conserved and describing the axial and rhombic anisotropies of the molecule, DM and EM, respectively, is not possible. However, the giant spin of the low-lying large MS states is very nearly an integer and, using this spin value, it is possible to construct an effective spin-Hamiltonian and compute the molecular magnetic anisotropy constants DM and EM. We report effect of finite sizes, rotations of site anisotropies and chain dimerisation on the effective anisotropy of the spin chains.
Multi-task functional MRI in multiple sclerosis patients without clinical disability.
Colorado, René A; Shukla, Karan; Zhou, Yuxiang; Wolinsky, Jerry S; Narayana, Ponnada A
2012-01-02
While the majority of individuals with multiple sclerosis (MS) develop significant clinical disability, a subset experiences a disease course with minimal impairment even in the presence of significant apparent tissue damage on magnetic resonance imaging (MRI). Functional magnetic resonance imaging (fMRI) in MS patients with low disability suggests that increased use of the cognitive control system may limit the clinical manifestation of the disease. The current fMRI studies tested the hypothesis that nondisabled MS patients show increased recruitment of cognitive control regions while performing sensory, motor and cognitive tasks. Twenty two patients with relapsing-remitting MS and an Expanded Disability Status Scale (EDSS) score of ≤1.5 and 23 matched healthy controls were recruited. Subjects underwent fMRI while observing flashing checkerboards, performing right or left hand movements, or executing the 2-back working memory task. Compared to control subjects, patients demonstrated increased activation of the right dorsolateral prefrontal cortex and anterior cingulate cortex during the performance of the working memory task. This pattern of functional recruitment also was observed during the performance of non-dominant hand movements. These results support the mounting evidence of increased functional recruitment of cognitive control regions in the working memory system of MS patients with low disability and provide new evidence for the role of increased cognitive control recruitment in the motor system. Copyright © 2011 Elsevier Inc. All rights reserved.
NASA Astrophysics Data System (ADS)
Morgan, Dylan P.; West, Andrew A.; Becker, Andrew C.
2016-05-01
We present a study of the statistical flare rates of M dwarfs (dMs) with close white dwarf (WD) companions (WD+dM; typical separations <1 au). Our previous analysis demonstrated that dMs with close WD companions are more magnetically active than their field counterparts. One likely implication of having a close binary companion is increased stellar rotation through disk-disruption, tidal effects, and/or angular momentum exchange; increased stellar rotation has long been associated with an increase in stellar activity. Previous studies show a strong correlation between dMs that are magnetically active (showing Hα in emission) and the frequency of stellar flare rates. We examine the difference between the flare rates observed in close WD+dM binary systems and field dMs. Our sample consists of a subset of 181 close WD+dM pairs from Morgan et al. observed in the Sloan Digital Sky Survey Stripe 82, where we obtain multi-epoch observations in the Sloan ugriz-bands. We find an increase in the overall flaring fraction in the close WD+dM pairs (0.09 ± 0.03%) compared to the field dMs (0.0108 ± 0.0007%) and a lower flaring fraction for active WD+dMs (0.05 ± 0.03%) compared to active dMs (0.28 ± 0.05%). We discuss how our results constrain both the single and binary dM flare rates. Our results also constrain dM multiplicity, our knowledge of the Galactic transient background, and may be important for the habitability of attending planets around dMs with close companions.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Jayaraman, T. V.; Meka, V. M.; Jiang, X.
In this work, we investigated the ambient temperature structural properties (~300 K) and the ambient and high temperature (up to 900 K) direct current (DC) magnetic properties of melt-spun Fe-x wt.% Si (x = 3, 5, & 8) alloys. The wheel surface speeds selected for the study were 30 m/s and 40 m/s. The thickness, width, lattice parameter, saturation magnetization (MS), and intrinsic coercivity (HCI) of the melt spun ribbons are presented and compared with data in the literature. The ribbons produced at the lower wheel surface speed (30 m/s) were continuous having relatively uniform edges compared to the ribbonsmore » produced at the higher wheel surface speed. The thickness and the width of the melt-spun ribbons ranged between ~15-60 μm and 500-800 μm, respectively. The x-ray diffraction spectra of the melt-spun ribbons indicated the presence of disordered α-phase, irrespective of the composition, and the wheel-surface speed. The lattice parameter decreased gradually as a function of increasing silicon content from ~0.2862 nm (Fe-3 wt.% Si) to ~0.2847 nm (Fe-8 wt.% Si). Wheel surface speed was not shown to have a significant effect on the magnetization, but primarily impacted the ribbon structure. A decreasing trend in the saturation magnetization was observed as a function of increased silicon content. The intrinsic coercivity of the melt-spun alloys ranged between ~50 to 200 A/m. Elevated temperature evaluation of the magnetization in the case of Fe-3 & 5 wt.% Si alloy ribbons was distinctly different from the Fe-8 wt.% Si alloy ribbons. The curves of the as-prepared Fe-3 wt.% Si and Fe-5 wt.% Si alloy ribbons were irreversible while that of Fe-8 wt.% Si was reversible. The MS for any of the combinations of wheel surface speed and composition decreased monotonically with the increase in temperature (from 300 – 900 K). The percentage decrease in MS from 300 K to 900 K for the Fe-3 wt.% Si and Fe-5 wt.% Si alloys was ~19-22 %, while the percentage decrease in the same temperature range for Fe-8 wt.% Si alloy was ~26-30 %. It appears that Fe-3 wt.% Si and Fe-5 wt.% Si alloys ribbons are primarily comprised of the α phase (disordered phase) with any minor constituents being beyond the detection limits of the studies performed, while the Fe-8 wt.% Si alloy ribbons are comprised of disordered and regions of short-range ordering.« less
NASA Astrophysics Data System (ADS)
Tang, Jin; Liu, Xiansong; Mehmood Ur Rehman, Khalid; Li, Dan; Li, Mingling; Yang, Yujie
2018-04-01
We report a successful preparation of Ba1-xLaxFe22+Fe163+O27 (x = 0.00-0.10) W-type hexagonal ferrites by standard ceramic method in a reduced oxygen atmosphere. In this work, the effect of the substitution La3+ rare-earth ions for Ba2+ ions on the structural and magnetic properties of the prepared samples have been studied. The phase identification of magnetic powders was performed by X-ray diffraction. The results of XRD show that the single phase was observed in the W-type ferrites with different La content. The SEM micrographs showed that the ferrites have formed the hexagonal structure. The magnetic properties of the samples were metric by a vibrating sample magnetometer. The coercivity (Hc) of the particles decreases with the increase of La content(x), while the saturation magnetization (Ms) of the particles first increases with x from 0 to 0.05, and then begins to decrease when x continues to increase. The monotonic dependence of the magnetic anisotropy field Ha and coercivity Hc on the La3+ doping amount is found to be mainly dominated by the competition between Ms and Keff.
Tang, Alexander D; Hong, Ivan; Boddington, Laura J; Garrett, Andrew R; Etherington, Sarah; Reynolds, John N J; Rodger, Jennifer
2016-10-29
Repetitive transcranial magnetic stimulation (rTMS) has become a popular method of modulating neural plasticity in humans. Clinically, rTMS is delivered at high intensities to modulate neuronal excitability. While the high-intensity magnetic field can be targeted to stimulate specific cortical regions, areas adjacent to the targeted area receive stimulation at a lower intensity and may contribute to the overall plasticity induced by rTMS. We have previously shown that low-intensity rTMS induces molecular and structural plasticity in vivo, but the effects on membrane properties and neural excitability have not been investigated. Here we investigated the acute effect of low-intensity repetitive magnetic stimulation (LI-rMS) on neuronal excitability and potential changes on the passive and active electrophysiological properties of layer 5 pyramidal neurons in vitro. Whole-cell current clamp recordings were made at baseline prior to subthreshold LI-rMS (600 pulses of iTBS, n=9 cells from 7 animals) or sham (n=10 cells from 9 animals), immediately after stimulation, as well as 10 and 20min post-stimulation. Our results show that LI-rMS does not alter passive membrane properties (resting membrane potential and input resistance) but hyperpolarises action potential threshold and increases evoked spike-firing frequency. Increases in spike firing frequency were present throughout the 20min post-stimulation whereas action potential (AP) threshold hyperpolarization was present immediately after stimulation and at 20min post-stimulation. These results provide evidence that LI-rMS alters neuronal excitability of excitatory neurons. We suggest that regions outside the targeted region of high-intensity rTMS are susceptible to neuromodulation and may contribute to rTMS-induced plasticity. Copyright © 2016 IBRO. All rights reserved.
Ciccarelli, O.; Altmann, D. R.; McLean, M. A.; Wheeler-Kingshott, C. A.; Wimpey, K.; Miller, D. H.; Thompson, A. J.
2010-01-01
Objective: To investigate the mechanisms of spinal cord repair and their relative contribution to clinical recovery in patients with multiple sclerosis (MS) after a cervical cord relapse, using spinal cord 1H-magnetic resonance spectroscopy (MRS) and volumetric imaging. Methods: Fourteen patients with MS and 13 controls underwent spinal cord imaging at baseline and at 1, 3, and 6 months. N-acetyl-aspartate (NAA) concentration, which reflects axonal count and metabolism in mitochondria, and the cord cross-sectional area, which indicates axonal count, were measured in the affected cervical region. Mixed effect linear regression models investigated the temporal evolution of these measures and their association with clinical changes. Ordinal logistic regressions identified predictors of recovery. Results: Patients who recovered showed a sustained increase in NAA after 1 month. In the whole patient group, a greater increase of NAA after 1 month was associated with greater recovery. Patients showed a significant decline in cord area during follow-up, which did not correlate with clinical changes. A worse recovery was predicted by a longer disease duration at study entry. Conclusions: The partial recovery of N-acetyl-aspartate levels after the acute event, which is concurrent with a decline in cord cross-sectional area, may be driven by increased axonal mitochondrial metabolism. This possible repair mechanism is associated with clinical recovery, and is less efficient in patients with longer disease duration. These insights into the mechanisms of spinal cord repair highlight the need to extend spinal cord magnetic resonance spectroscopy to other spinal cord disorders, and explore therapies that enhance recovery by modulating mitochondrial activity. GLOSSARY CI = confidence interval; EDSS = Expanded Disability Status Scale; FOV = field of view; MR = magnetic resonance; MRS = magnetic resonance spectroscopy; MS = multiple sclerosis; NAA = N-acetyl-aspartate; SC = spinal cord; TE = echo time; TI = inversion time; TR = repetition time. PMID:20107138
NASA Astrophysics Data System (ADS)
Wang, Bo; Pan, Zihe; Cheng, Huaigang; Chen, Zuliang; Cheng, Fangqin
2018-06-01
Vaterite-type calcium carbonate particles have some unique properties such as high hydrophilicity, large surface areas, and hierarchical structures consisting of primary vaterite particles in comparison with calcite or aragonite-type polymorphs. In this paper, gypsum (CaSO4·2H2O) suspension is used to synthesize micro-sized vaterite CaCO3 through magnetic stirring (MS) and ultrasonic probe vibration (UPV) methods. The effects of ammonia concentration, CO2 flow rate, solid-liquid ratio on the gypsum carbonation process, mineral phase composition, morphology and particle size distribution of CaCO3 are investigated. The results show that the carbonation process is significantly influenced by ammonia concentration, CO2 flow rate and ultrasound. Comparing with magnetic stirring, ultrasonic probe vibration take less time to reach the complete carbonate reaction. Gypsum is transformed to vaterite with the conversion rate about ∼95% when the mole ratio of NH4+/Ca2+ is 2.4 otherwise the carbonation reaction was uncompleted with gypsum residues left. Comparing with MS method, the UPV method resulted in smaller size and narrower size distribution of as-prepared microparticles and approximately 80% reduction of the particle size was achieved. It is established that increasing the solid-liquid ratio resulted in larger particle size in MS system and smaller particle size in UPV system. Increasing CO2 flow rate caused the particle size decreased in MS system and increased in UPV system.
NASA Astrophysics Data System (ADS)
Rehman, Khalid Mehmood Ur; Liu, Xiansong; Yang, Yujie; Feng, Shuangjiu; Tang, Jin; Ali, Zulfiqar; Wazir, Z.; Khan, Muhammad Wasim; Shezad, Mudssir; Iqbal, Muhammad Shahid; Zhang, Cong; Liu, Chaocheng
2018-03-01
In present work, M-type strontium hexaferrite with chemical composition of Sr0.3La0.48Ca0.25n[Fe(2-0.4/n)O3]Co0.4 (n = 5.5, 5.6, 5.7, 5.8, 5.9, 6.0) magnetic powder were synthesized by using facile ceramic route methodology. The structural, morphological and magnetic properties of the products were investigated by using X-rays diffraction (XRD), Scanning Electron Microscopy (SEM) and Vibrating Sample Magnetometer (VSM) techniques, respectively. There is a single magnetoplumbite phase in the magnetic powders containing (5.5 ≤ n ≤5.8) and (n ≥ 5.9) magnetic some impurities begin to seem in the structure. The magnets have shaped hexagonal structures. Magnetic properties of the samples were metric by permanent magnetic measuring equipment Vibrating Sample Magnetometer, respectively. We report our investigation of n-aggregation iron content on crystalline size characterization and magnetic properties of the specimen. It is originate that the desirable quantity of n-aggregation iron content substitution may curiously increase saturation magnetization (Ms) and intrinsic coercivity (Hc). With the iron addition for the same sintering temperature at 1260 °C, (Ms) and (Hc) first increase and then decrease gradually.
Magnetic susceptibility as an indicator of heavy metal contamination in compost.
Paradelo, Remigio; Moldes, Ana Belén; Barral, María Teresa
2009-02-01
One of the main restrictions to the agronomic use of compost is the excess of heavy metals, which are often present due to inadequate separation of biodegradable fractions from non-degradable or inert materials. Magnetic susceptibility (MS) measurements are a simple technique that has been reported as a useful tool for assessing anthropogenic pollution, especially heavy metal pollution on soil and sediment samples. The close relationship of MS with heavy metal contamination has been proved by combined analyses of chemical and magnetic data. In this study, the MS and total heavy metal concentrations of eight composts from different origins were determined; all composts were passed under a magnet to remove the magnetic material, and total heavy metals were determined again. In our work, high correlations were found between magnetic susceptibility and total Cd, Zn, Pb, Cr and Ni, thus confirming the applicability of MS measurement as a proxy for heavy metal contamination in compost quality assessments. The application of a magnet over the composts reduced the MS as well as the heavy metal content, the reduction of Fe and MS being the most significantly correlated. Thus, the inclusion of an additional magnetic separation step in the post-process compost finishing could be envisaged.
Li, Ting; Wang, Wei; Kong, De-lei; Su, Jiao; Kang, Jian
2012-04-01
To explore the influence of intermittent hypoxia on the responses of genioglossus motor cortex to transcranial magnetic stimulation. Male Sprague-Dawley rats were randomly divided into a control group and a chronic intermittent hypoxia group. Transcranial magnetic stimulation was applied in genioglossus motor cortex of the 2 groups. The responses of transcranial magnetic stimulation were recorded and analyzed by single factor analysis of variance. The anterolateral area provided an optimal motor evoked potential response to transcranial magnetic stimulation in the genioglossus motor cortex of the rats. Genioglossus motor evoked potential latency and amplitude were significantly modified by intermittent hypoxic exposure, with a significant decrease in latency (F = 3.294, P < 0.01) at the 1st day [(4.90 ± 0.54) ms] and the 14th day [(4.64 ± 1.71) ms], and an increase in amplitude (F = 1.905, P < 0.05) at the 1st day [(2.28 ± 0.57) mV] and the 7th day [(1.89 ± 0.20) mV]. Intermittent hypoxia could increase the transcranial magnetic stimulation response of genioglossus motor cortex in rats.
Advanced MRI in Multiple Sclerosis: Current Status and Future Challenges
Fox, Robert J.; Beall, Erik; Bhattacharyya, Pallab; Chen, Jacqueline; Sakaie, Ken
2011-01-01
Synopsis Magnetic resonance imaging (MRI) has rapidly become a leading research tool in the study of multiple sclerosis (MS). Conventional imaging is useful in diagnosis and management of the inflammatory stages of MS, but has limitations in describing the degree of tissue injury as well as the cause of progressive disability seen in the later stages of disease. Advanced MRI techniques hold promise to fill this void. Magnetization transfer imaging is a widely available technique that can characterize demyelination and may be useful in measuring putative remyelinating therapies. Diffusion tensor imaging describes the three-dimensional diffusion of water and holds promise in characterizing neurodegeneration and putative neuroprotective therapies. Spectroscopy measures the imbalance of cellular metabolites and could help unravel the pathogenesis of neurodegeneration in MS. Functional (f) MRI can be used to understand the functional consequences of MS injury, including the impact on cortical function and compensatory mechanisms. These imaging tools hold great promise to increase our understanding of MS pathogenesis and provide greater insight into the efficacy of new MS therapies. PMID:21439446
Elgeti, Thomas; Tzschätzsch, Heiko; Hirsch, Sebastian; Krefting, Dagmar; Klatt, Dieter; Niendorf, Thoralf; Braun, Jürgen; Sack, Ingolf
2012-04-01
Vibration synchronized magnetic resonance imaging of harmonically oscillating tissue interfaces is proposed for cardiac magnetic resonance elastography. The new approach exploits cardiac triggered cine imaging synchronized with extrinsic harmonic stimulation (f = 22.83 Hz) to display oscillatory tissue deformations in magnitude images. Oscillations are analyzed by intensity threshold-based image processing to track wave amplitude variations over the cardiac cycle. In agreement to literature data, results in 10 volunteers showed that endocardial wave amplitudes during systole (0.13 ± 0.07 mm) were significantly lower than during diastole (0.34 ± 0.14 mm, P < 0.001). Wave amplitudes were found to decrease 117 ± 40 ms before myocardial contraction and to increase 75 ± 31 ms before myocardial relaxation. Vibration synchronized magnetic resonance imaging improves the temporal resolution of magnetic resonance elastography as it overcomes the use of extra motion encoding gradients, is less sensitive to susceptibility artifacts, and does not suffer from dynamic range constraints frequently encountered in phase-based magnetic resonance elastography. Copyright © 2012 Wiley Periodicals, Inc.
Anobom, C. D.; Albuquerque, S. C.; Albernaz, F. P.; Oliveira, A. C.; Silva, J. L.; Peabody, D. S.; Valente, A. P.; Almeida, F. C. L.
2003-01-01
In this article we studied, by nuclear magnetic resonance relaxation measurements, the disassembly of a virus particle—the MS2 bacteriophage. MS2 is one of the single-stranded RNA bacteriophages that infect Escherichia coli. At pH 4.5, the phage turns to a metastable state, as is indicated by an increase in the observed nuclear magnetic resonance signal intensity upon decreasing the pH from 7.0 to 4.5. Steady-state fluorescence and circular dichroism spectra at pH 4.5 show that the difference in conformation and secondary structure is not pronounced if compared with the phage at pH 7.0. At pH 4.5, two-dimensional 15N-1H heteronuclear multiple quantum coherence (HMQC) spectrum shows ∼40 crosspeaks, corresponding to the most mobile residues of MS2 coat protein at pH 4.5. The 15N linewidth is ∼30 Hz, which is consistent with an intermediate with a rotational relaxation time of 100 ns. The average spin lattice relaxation time (T1) of the mobile residues was measured at different temperatures, clearly distinguishing between the dimer and the equilibrium intermediate. The results show, for the first time, the presence of intermediates in the process of dissociation of the MS2 bacteriophage. PMID:12770895
NASA Astrophysics Data System (ADS)
Raghuvanshi, S.; Kane, S. N.; Tatarchuk, T. R.; Mazaleyrat, F.
2018-05-01
Effect of Zn addition on cationic distribution, structural properties, magnetic properties, antistructural modeling of nanocrystalline Co1-xZnxFe2O4 (0.08 ≤ x ≤ 0.56) ferrite is reported. XRD confirms the formation of single phase cubic spinel nano ferrites with average grain diameter ranging between 41.2 - 54.9 nm. Coercivity (Hc), anisotropy constant (K1) decreases with Zn addition, but experimental, theoretical saturation magnetization (Ms, Ms(t)) increases upto x = 0.32, then decreases, attributed to the breaking of collinear ferrimagnetic phase. Variation of magnetic properties is correlated with cationic distribution. A new antistructural modeling for describing active surface centers is discussed to explain change in concentration of donor's active centers Zn'B, Co'B, acceptor's active centers Fe*A are explained.
Hezel, Fabian; Thalhammer, Christof; Waiczies, Sonia; Schulz-Menger, Jeanette; Niendorf, Thoralf
2012-01-01
Myocardial tissue characterization using T2 * relaxation mapping techniques is an emerging application of (pre)clinical cardiovascular magnetic resonance imaging. The increase in microscopic susceptibility at higher magnetic field strengths renders myocardial T2 * mapping at ultrahigh magnetic fields conceptually appealing. This work demonstrates the feasibility of myocardial T2 * imaging at 7.0 T and examines the applicability of temporally-resolved and high spatial resolution myocardial T2 * mapping. In phantom experiments single cardiac phase and dynamic (CINE) gradient echo imaging techniques provided similar T2 * maps. In vivo studies showed that the peak-to-peak B0 difference following volume selective shimming was reduced to approximately 80 Hz for the four chamber view and mid-ventricular short axis view of the heart and to 65 Hz for the left ventricle. No severe susceptibility artifacts were detected in the septum and in the lateral wall for T2 * weighting ranging from TE = 2.04 ms to TE = 10.2 ms. For TE >7 ms, a susceptibility weighting induced signal void was observed within the anterior and inferior myocardial segments. The longest T2 * values were found for anterior (T2 * = 14.0 ms), anteroseptal (T2 * = 17.2 ms) and inferoseptal (T2 * = 16.5 ms) myocardial segments. Shorter T2 * values were observed for inferior (T2 * = 10.6 ms) and inferolateral (T2 * = 11.4 ms) segments. A significant difference (p = 0.002) in T2 * values was observed between end-diastole and end-systole with T2 * changes of up to approximately 27% over the cardiac cycle which were pronounced in the septum. To conclude, these results underscore the challenges of myocardial T2 * mapping at 7.0 T but demonstrate that these issues can be offset by using tailored shimming techniques and dedicated acquisition schemes. PMID:23251708
NASA Astrophysics Data System (ADS)
Manohar, A.; Krishnamoorthi, C.
2017-12-01
Majority studies on magnetic hyperthermia properties were carried out by modifying the saturation mass magnetization (Ms) of the samples. Here efforts were made to enhance the specific heat generation rate (SHGR) of single domain superparamagnetic (SP) material by modifying its magnetic susceptibility. Well crystallined, inverse spinel structured and close to monosize Fe1-xMgxFe2O4 (x = 0, 0.1, 0.2, 0.3, 0.4, & 0.5) compounds with nanosphere geometry (diameter 10 nm) were synthesized by solvothermal reflux method at ≈ 300 °C . In the literature it is reported that magnesium ferrites synthesized at high temperatures yield mixed (normal & inverse) spinel structures. The inverse spinel structure was confirmed by X-ray powder diffraction (XRPD), lattice vibrations and magnetic characteristics of the compounds. The Ms of the compounds decrease with increase of substituent Mg2+ concentration. Under high excitation energy the inter-valance charge transfer whereas under low excitation energy the intra-valance charge transfer process were predominant. The as-synthesized nanospheres were encapsulated by hydrophobic oleic acid and were exchanged by hydrophilic poly(acrylic acid) by chemical exchange process. Estimated magnetic hyperthermia power or SHGR of the x = 0, 0.3 & 0.5 were 11, 11.4 & 22.4 W per gram of respective compounds, respectively, under 63.4 kA m-1 field amplitude and 126 kHz frequency. The SHGR enhances with Mg2+ concentration though its Ms reduces and is attributed to reduced spin-orbital coupling in the compounds with enhanced Mg2+ concentration. This may pave a new way to develop magnetic hyperthermia material by modifying magnetic susceptibility of the compounds against to the reported Ms modification approach. The obtained high SHGR of the biocompatible compounds could be used in magnetic hyperthermia applications in biomedical field.
Thickness-modulated anisotropic ferromagnetism in Fe-doped epitaxial HfO2 thin films
NASA Astrophysics Data System (ADS)
Liu, Wenlong; Liu, Ming; Zhang, Ruyi; Ma, Rong; Wang, Hong
2017-10-01
Epitaxial tetragonal Fe-doped Hf0.95Fe0.05O2 (FHO) thin films with various thicknesses were deposited on (001)-oriented NdCaAlO4 (NCAO) substrates by using a pulsed laser deposition (PLD) system. The crystal structure and epitaxial nature of the FHO thin films were confirmed by typical x-ray diffraction (XRD) θ-2θ scan and reciprocal space mapping (RSM). The results indicate that two sets of lattice sites exist with two different crystal orientations [(001) and (100)] in the thicker FHO thin films. Further, the intensity of the (100) direction increases with the increase in thicknesses, which should have a significant effect on the anisotropic magnetization of the FHO thin films. Meanwhile, all the FHO thin films possess a tetragonal phase structure. An anisotropy behavior in magnetization has been observed in the FHO thin films. The anisotropic magnetization of the FHO thin films is slowly weakened as the thickness increases. Meanwhile, the saturation magnetization (Ms) of both in-plane and out-of-plane decreases with the increase in the thickness. The change in the anisotropic magnetization and Ms is attributed to the crystal lattice and the variation in the valence of Fe ions. These results indicate that the thickness-modulated anisotropic ferromagnetism of the tetragonal FHO epitaxial thin films is of potential use for the integration of metal-oxide semiconductors with spintronics.
NASA Astrophysics Data System (ADS)
Lin, Ching-Yi; Huang, Whitney J.; Li, Kevin; Swanson, Roy; Cheung, Brian; Lin, Vernon W.; Lee, Yu-Shang
2015-04-01
Objective. Magnetic stimulation (MS) is a potential treatment for neuropsychiatric disorders. This study investigates whether MS-regulated neuronal activity can translate to specific changes in neuronal arborization and thus regulate synaptic activity and function. Approach. To test our hypotheses, we examined the effects of MS on neurite growth of neuroscreen-1 (NS-1) cells over the pulse frequencies of 1, 5 and 10 Hz at field intensities controlled via machine output (MO). Cells were treated with either 30% or 40% MO. Due to the nature of circular MS coils, the center region of the gridded coverslip (zone 1) received minimal (∼5%) electromagnetic current density while the remaining area (zone 2) received maximal (∼95%) current density. Plated NS-1 cells were exposed to MS twice per day for three days and then evaluated for length and number of neurites and expression of brain-derived neurotrophic factor (BDNF). Main results. We show that MS dramatically affects the growth of the longest neurites (axon-like) but does not significantly affect the growth of shorter neurites (dendrite-like). Also, MS-induced changes in the longest neurite growth were most evident in zone 1, but not in zone 2. MS effects were intensity-dependent and were most evident in bolstering longest neurite outgrowth, best seen in the 10 Hz MS group. Furthermore, we found that MS-increased BDNF expression and secretion was also frequency-dependent. Taken together, our results show that MS exerts distinct effects when different frequencies and intensities are applied to the neuritic compartments (longest neurite versus shorter dendrite(s)) of NS-1 cells. Significance. These findings support the concept that MS increases BDNF expression and signaling, which sculpts longest neurite arborization and connectivity by which neuronal activity is regulated. Understanding the mechanisms underlying MS is crucial for efficiently incorporating its use into potential therapeutic strategies.
Magnetosonic Solitons in Non-Maxwellian Space Plasmas
NASA Astrophysics Data System (ADS)
Pokhotelov, O. A.; Balikhin, M.; Onishchenko, O. G.
2006-12-01
The nonlinear theory of large-amplitude magnetosonic (MS) waves in high-beta space plasmas is developed. It is shown that solitary waves can exist in the form of magnetic humps and holes in which the magnetic field is increased or decreased relative to the background magnetic field. This depends on the shape of the equilibrium ion velocity distribution function. The basic parameter that controls the nonlinear structure is the wave dispersion which can be either positive or negative. A general dispersion relation for MS waves propagating perpendicularly to the external magnetic field in a plasma with an arbitrary velocity distribution function is derived. It takes into account general plasma equilibria such as the Dory-Guest-Harris or Kennel- Ashour-Abdalla loss cone equilibria, as well as distributions with a power law velocity dependence that can be modelled by kappa-distributions. It is shown that in Maxwellian and bi-Maxwellian plasmas the dispersion is negative, i.e. the phase velocity decreases with an increase of the wave number. This means that the solitary solution in this case has the form of a magnetic hump with the magnetic field increased. On the contrary, in some non-Maxwellian plasmas such as those with ring-type ion distributions or DGH plasmas, the solitary solution may have the form of a magnetic hole. The results of similar investigations based on nonlinear Hall-MHD equations are reviewed. The relevance of our theoretical results to experimental observations is outlined
NASA Astrophysics Data System (ADS)
Yang, Juan-Cheng; Qi, Tian-Yu; Han, Tian-Yang; Zhang, Jie; Ni, Ming-Jiu
2018-01-01
The spreading characteristics of a liquid GaInSn alloy droplet on a glass surface with the action of a horizontal magnetic field have been experimentally investigated in the present paper. With changing the impact velocity from 0.1 m/s to 1.2 m/s and increasing the magnetic field from 0 T to 1.6 T, we focus on studying the influence of the horizontal magnetic field on the spreading characteristics of a liquid metal droplet using the shadow-graph method. The elliptical spreading pattern of a liquid metal droplet induced by the horizontal magnetic field was discovered by experiments. By introducing a numerical method in getting the distribution of current lines and the Lorentz force inside the droplet, we give a detailed explanation on the mechanism of elliptical spreading. Furthermore, some quantitative results on a maximum spreading factor and time at moment of maximum spreading varied with the Hartmann number and Weber number are shown to give us a comprehensive understanding of the elliptical spreading. With the increasing of the magnetic field, the maximum spreading factor in the front view is reduced while that in the side view is increased, which reveals a larger deformation happened during the spreading process. While with the increasing of impact velocity, the spreading factor increased. Finally, we present a non-dimensional parameter to get scaling laws for the averaged maximum spreading factor and the aspect ratio of the maximum spreading factor; results show that the predict data can agree with experimental data in a certain degree.
NASA Astrophysics Data System (ADS)
Kuru, Hilal; Kockar, Hakan; Alper, Mursel
2017-12-01
Giant magnetoresistance (GMR) behavior in electrodeposited NiFe/Cu multilayers was investigated as a function of non-magnetic (Cu) and ferromagnetic (NiFe) layer thicknesses, respectively. Prior to the GMR analysis, structural and magnetic analyses of the multilayers were also studied. The elemental analysis of the multilayers indicated that the Cu and Ni content in the multilayers increase with increasing Cu and NiFe layer thickness, respectively. The structural studies by X-ray diffraction revealed that all multilayers have face centred cubic structure with preferred (1 1 0) crystal orientation as their substrates. The magnetic properties studied with the vibrating sample magnetometer showed that the magnetizations of the samples are significantly affected by the layer thicknesses. Saturation magnetisation, Ms increases from 45 to 225 emu/cm3 with increasing NiFe layer thickness. The increase in the Ni content of the multilayers with a small Fe content causes an increase in the Ms. And, the coercivities ranging from 2 to 24 Oe are between the soft and hard magnetic properties. Also, the magnetic easy axis of the multilayers was found to be in the film plane. Magnetoresistance measurements showed that all multilayers exhibited the GMR behavior. The GMR magnitude increases with increasing Cu layer thickness and reaches its maximum value of 10% at the Cu layer thickness of 1 nm, then it decreases. And similarly, the GMR magnitude increases and reaches highest value of pure GMR (10%) for the NiFe layer thickness of 3 nm, and beyond this point GMR decreases with increasing NiFe layer thickness. Some small component of the anisotropic magnetoresistance was also observed at thin Cu and thick NiFe layer thicknesses. It is seen that the highest GMR values up to 10% were obtained in electrodeposited NiFe/Cu multilayers up to now. The structural, magnetic and magnetoresistance properties of the NiFe/Cu were reported via the variations of the thicknesses of Cu and NiFe layers with stressing the role of layer thicknesses on the high GMR behavior.
NASA Astrophysics Data System (ADS)
Tekgül, Atakan; Kockar, Hakan; Kuru, Hilal; Alper, Mürsel; ÜnlÜ, C. Gökhan
2018-03-01
The electrochemical, structural and magnetic properties of CoCu/Cu multilayers electrodeposited at different cathode potentials were investigated from a single bath. The Cu layer deposition potentials were selected as - 0.3, V - 0.4 V, and - 0.5 V with respect to saturated calomel electrode (SCE) while the Co layer deposition potential was constant at - 1.5 V versus SCE. For the electrochemical analysis, the current-time transients were obtained. The amount of noble non-magnetic (Cu) metal materials decreased with the increase of deposition potentials due to anomalous codeposition. Further, current-time transient curves for the Co layer deposition and capacitance were calculated. In the structural analysis, the multilayers were found to be polycrystalline with both Co and Cu layers adopting the face-centered cubic structure. The (111) peak shifts towards higher angle with the increase of the deposition potentials. Also, the lattice parameters of the multilayers decrease from 0.3669 nm to 0.3610 nm with the increase of the deposition potentials from - 0.3 V to - 0.5 V, which corresponds to the bulk values of Cu and Co, respectively. The electrochemical and structural results demonstrate that the amount of Co atoms increased and the Cu atoms decreased in the layers with the increase of deposition potentials due to anomalous codeposition. For magnetic measurements, the saturation magnetizations, M_s obtained from the magnetic curves of the multilayers were obtained as 212 kA/m, 276 kA/m, and 366 kA/m with - 0.3 V, - 0.4 V, and - 0.5 V versus SCE, respectively. It is seen that the M_s values increased with the increase of the deposition potentials confirming the increase of the Co atoms and decrease of the Cu amount. The results of electrochemical and structural analysis show that the deposition potentials of non-magnetic layers plays important role on the amount of magnetic and non-magnetic materials in the layers and thus on the magnetic properties of the multilayers.
Alveolar air-tissue interface and nuclear magnetic resonance behavior of the lung
NASA Astrophysics Data System (ADS)
Cutillo, Antonio G.; Ailion, David C.; Ganesan, Krishnamurthy; Morris, Alan H.; Durney, Carl H.
1995-05-01
The nuclear magnetic resonance (NMR) properties of lung are markedly affected by the alveolar air-tissue interface, which produces internal magnetic field inhomogeneity because of the different magnetic susceptibilities of air and water. This internal magnetic field inhomogeneity results in a marked shortening of the free induction decay (FID) (in the time domain) and in inhomogeneous NMR line broadening (in the frequency domain). The signal loss due to internal magnetic field inhomogeneity can be measured as the difference Δ between the spin-echo signals obtained using temporally symmetric and asymmetric spin-echo sequences; the degree of asymmetry of the asymmetric sequence is characterized by the asymmetry time τa. In accordance with predictions based on the analysis of theoretical models, experiments in excised rat lungs (studied at various inflation levels) have shown that Δ depends on τa and is very low in degassed lungs. When measured at τa equals 6 ms, the difference signal (Δ6ms) increases markedly with alveolar opening but does not vary significantly during the rest of the inflation-deflation cycle. In edematous (oleic acid-injured) lungs, the values of Δ6ms measured at low inflation levels are significantly below those observed in normal lungs. These results suggest that Δ6ms is very sensitive to alveolar recruitment and relatively insensitive to alveolar distension. Therefore, measurements of Δ6ms may provide a means of assessing the relative contributions of these two factors to the pressure-volume behavior of lung. Such measurements may contribute to the characterization of pulmonary edema (for example, by detecting the loss of alveolar air-tissue interface due to alveolar flooding, by differentiating interstitial from alveolar pulmonary edema, and by assessing the effects of positive airway pressures). NMR lineshape measurements can also provide valuable information regarding lung geometry and the characterization of pulmonary edema.
Magnetic properties of La0.95Sr0.05CoO3 nanoparticles
NASA Astrophysics Data System (ADS)
Prakash, Ravi; Shukla, Rishabh; Priyanka, Dhaka, R. S.
2017-05-01
We report the magnetic and structural properties of La(1-x)SrxCoO3 (x = 0 & 0.05) nanoparticles. The analysis of room temperature powder x-ray diffraction confirms the crystalline nature and single phase of the prepared samples. The magnetic measurements show ferromagnetic transition at TC˜85 K, the spontaneous magnetic moment MS ˜172 emu/mol, and the coercive field HC ˜7 kOe in parent compound, which are in agreement with the literature. Interestingly, with hole doping by Sr2+ substitution at La3+ site the magnetization data show drastic changes, as the TC increases to ˜270 K, the value of MS (˜557 emu/mole) increases about three times, whereas, the HC (˜0.6 kOe) decreases. Below TC, the nanoparticles show a much larger FC moment and a significant difference in FC and ZFC (zero field cooled) behaviors. For x = 0.05, we determined the values of effective magnetic moment (µeff = 3.62 µB/Co), the Curie temperature (θCW = -28 K) and the spin state (Savg = 1.38), which are significantly different than LaCoO3. Our study suggests an important role of charge carriers in controlling of intermediate spin state by hole doping in nanoparticles.
Peter, Jochen F; Otto, Angela M
2010-02-01
The effective isolation and purification of proteins from biological fluids is the most crucial step for a successful protein analysis when only minute amounts are available. While conventional purification methods such as dialysis, ultrafiltration or protein precipitation often lead to a marked loss of protein, SPE with small-sized particles is a powerful alternative. The implementation of particles with superparamagnetic cores facilitates the handling of those particles and allows the application of particles in the nanometer to low micrometer range. Due to the small diameters, magnetic particles are advantageous for increasing sensitivity when using subsequent MS analysis or gel electrophoresis. In the last years, different types of magnetic particles were developed for specific protein purification purposes followed by analysis or screening procedures using MS or SDS gel electrophoresis. In this review, the use of magnetic particles for different applications, such as, the extraction and analysis of DNA/RNA, peptides and proteins, is described.
NASA Astrophysics Data System (ADS)
Famera, Martin; Matys Grygar, Tomas; Elznicova, Jitka
2017-04-01
Magnetic susceptibility is highly appreciated in sedimentary and environmental geology. It may also reflect provenance of the sediment and post-depositional changes therein, including soil-forming processes. We studied the applicability of Fe-normalization of mass-specific magnetic susceptibility (MS) and Ti-normalization of Fe concentrations in description of fluvial sediments from five different catchments. We dealt with two catchments with some "mafic" source rocks (Fe-rich rocks) and three almost purely "felsic" catchments (source rocks with dominant quartz and feldspars). The fine-grained floodplain sediments (from clayey silts to fine sands) were obtained by drill coring and analysed for Fe and Ti concentrations using X-ray fluorescence spectroscopy (EDXRF) and MS using kappabridge. To correct MS for the sedimentological grain-size effects and possible magnetic enrichment, we used background functions constructed in the same way like for heavy metals. The representative profiles downward the floodplain sediments demonstrate the following MS stratigraphy: (1) 15-50 cm thick top stratum A, usually with MS and heavy metal enrichment, (2) underlying stratum B with stable values of MS, MS/Fe and Fe/Ti and (3) the lowermost stratum C with variable Fe concentrations and MS and high-chroma reductimorphic features due to micro-accumulations of Fe and Mn oxides in discoloured matrix, or grey colour due to permanently removed Fe(III) oxide pigment. The boundary between strata B and C can be at a depth of several decimetres to more than 1 metre depending on the thickness of floodplain fines, site-specific river incision and water table fluctuation. For the construction of MS background functions we used Fe concentrations as an independent variable (a predictor). It allows for calculation of MS of sediments as it would not be affected by post-depositional changes and pollution. Pristine MS is than predicted for any sample using formula MS_PRISTINE = const·cFe + const', where cFe is concentration of Fe. Background functions must be obtained empirically from collection of samples of stratum B that needs qualified sampling strategy and informed data evaluation. Local enrichment factor of MS is then defined as LEF MS = MS/MS_PRISTINE. LEF MS is useful for study of MS depth profiles in both strata A and C. Floodplain sediments in river systems with catchment with "mafic" rock outcrops have MSPRISTINE by up to two orders of magnitude larger in comparison to systems with "felsic" source rocks. The carriers of magnetic signal in the "mafic" rock-derived sediments are affected by soil-forming processes, which gradually decrease their original MS, in particular in strata B and C. Post-depositional processes including pedogenesis, in particular reductimorphic processes, may thus alter MS/Fe. The reductimorphic processes in floodplain sediments may be revealed by "erratic" variations or a permanent increase of the Fe/Ti ratio. The advantage of using geochemical normalization of MS is that chemical analyses are currently nearly routinely performed in geochemical and pollution mapping studies and thus Fe concentrations are thus available for data processing. The combination of the mentioned handy proxies (MS and element composition) would definitely deserve broader use in environmental geology and monitoring.
Synthesis and magnetic properties of NiFe2-xSmxO4 nanopowder
NASA Astrophysics Data System (ADS)
Hassanzadeh-Tabrizi, S. A.; Behbahanian, Shahrzad; Amighian, Jamshid
2016-07-01
NiFe2-xSmxO4 (x=0.00, 0.05, 0.10 and 0.15) nanopowders were synthesized via a sol-gel combustion route. The structural studies were carried out by X-ray diffractometer, Fourier transform infrared spectroscopy, scanning electron microscopy and transmission electron microscopy. The XRD results confirmed the formation of single-phase spinel cubic structure. The crystallite size decreased with an increase of samarium ion concentration, while lattice parameter and lattice strain increased with samarium substitution. TEM micrographs showed that agglomerated nanoparticles with particle sizes ranging from 35 to 90 nm were obtained. The magnetic studies were carried out using vibrating sample magnetometer. Magnetic measurements revealed that the saturation magnetization (Ms) of NiFe2-xSmxO4 nanoparticles decreases with increasing Sm3+substitution. The reduction of saturation magnetization is attributed to the dilution of the magnetic interaction. The coercivity (Hc) of samples increases by adding samarium.
Mapping soil magnetic susceptibility and mineralogy in Ukraine
NASA Astrophysics Data System (ADS)
Menshov, Oleksandr; Pereira, Paulo; Kruglov, Oleksandr; Sukhorada, Anatoliy
2017-04-01
Soil suatainable planning is fundamental for agricultural areas. Soil mapping and modeling are increasingly used in agricultural areas in the entire world (Brevik et al., 2016). They are beneficial to land managers, to reduce soil degradation, increase soil productivity and their restoration. Magnetic susceptibility (MS) methods are low cost and accurate for the developing maps of agricultural areas.. The objective of this work is to identify the minerals responsible for MS increase in soils from the two study areas in Poltava and Kharkiv region. The thermomagnetic analyses were conducted using the KLY-4 with an oven apparatus. The hysteresis parameters were measured with the Rotating Magnetometer at the Geophysical Centre Dourbes, Belgium. The results showed that all of samples from Kharkiv area and the majortity of the samples collected in Poltava area represent the pseudo single domain (PSD) zone particles in Day plot. According to Hanesch et al. (2006), the transformation of goethite, ferrihydrite or hematite to a stronger ferrimagnetic phase like magnetite or maghemite is common in strongly magnetic soils with high values of organic carbon content. In our case of thermomagnetic study, the first peak on the heating curve near 260 ˚C indicates the presence of ferrihydrite which gradually transforms into maghemite (Jordanova et al., 2013). A further decrease in the MS identified on the heating curve may be related to the transformation of the maghemite to hematite. A second MS peak on the heating curve near 530 ˚C and the ultimate loss of magnetic susceptibility near 580 ˚C were caused by the reduction of hematite to magnetite. The shape of the thermomagnetic curves suggests the presence of single domain (SD) particles at room temperature and their transformation to a superparamagnetic (SP) state under heating. Magnetic mineralogical analyses suggest the presence of highly magnetic minerals like magnetite and maghemite as well as slightly magnetic goethite, ferrihydrite, and hematite. Pseudosingle-domain, single-domain, and superparamagnetic grains of pedogenic origin dominate in the chernozem soils of the Kharkiv and Poltava region. References Brevik, E. C., Calzolari, C., Miller, B. A., Pereira, P., Kabala, C., Baumgarten, A., Jordán, A.: Soil mapping, classification, and pedologic modeling: history and future directions, Geoderma, 264, 256-274, 2016. Hanesch, M., Stanjek, H., Petersen, N.: Thermomagnetic measurements of soil iron minerals: the role of organic carbon, Geophysical Journal International, 165, 1, 53-61, 2006. Jordanova, D., Jordanova, N., Werban, U.: Environmental significance of magnetic properties of Gley soils near Rosslau (Germany), Environ Earth Sci., 69, 1719-1732, 2013.
NASA Astrophysics Data System (ADS)
Sapkota, Birendra
Understanding the interactions and effects of biotic and abiotic factors on magnetic parameter measurements used to assess levels of pollutants requires experimental analysis of potential individual parameters. Using magnetic and chemical measurements, three separate experimental studies were conducted in order to evaluate the separate and combined effects of soil composition, atmospheric exposure, and contaminant levels on soil magnetic susceptibility (MS) measurements, plant growth and metal uptake by plants. Experiment 1 examined the effects of incorporating an artificial Fe-rich contaminant into a synthetic soil on surficial soil magnetic properties and plant growth inside a greenhouse. Periodic measurements of surficial soil MS showed significant decreases in MS values in the three treatments (two levels of Fe-contamination and controls), with the greatest reduction in soils with the most contamination, and the least in controls. Three potential causes were suggested: Fe uptake by plants, magnetic minerals transformation, and downward migration of Fe-particles. Some arguments for the first two causes were discussed; however, the third possibility was separately evaluated in the second and third experiments. In the follow-up study (Experiment 2) conducted to examine the effects of ambient atmospheric pollution on magnetic and chemical properties of soils and plant biomass, the overall surficial soil MS was found to be significantly higher in synthetic soils exposed to a natural atmosphere in comparison to controls placed in a greenhouse. Root biomass samples taken from the exposed soils had much higher trace/heavy metal concentrations. Such increases in soil MS and bioavailability of metals in the exposed soils indicate that atmospheric pollution affected the soil and plants grown in there. Microscopic observations of Fe-rich particles from the post-harvest exposed soil revealed morphologies similar to Fe-containing particulates from power plants and transportation and related sources. Experiment 3 examined the vertical migration behavior of Fe-particles in natural soils, and contaminated soil cores showed magnetic enhancement at depths of 2 to 9 cm, with the Fe-rich particles at that depth having very similar morphologies to the contaminant (magnetite powder) used, suggesting that the contaminant migrated vertically downward in soil at a observable rate, most likely due to infiltration of rainwater.
Effect of cobalt substitution on magnetic properties of Ba4Ni2-xCoxFe36O60 hexaferrite
NASA Astrophysics Data System (ADS)
Jiang, Xiaona; Li, Songze; Yu, Zhong; Harris, Vincent G.; Su, Zhijuan; Sun, Ke; Wu, Chuanjian; Guo, Rongdi; Lan, Zhongwen
2018-05-01
Co-substituted U-type hexagonal ferrite bulks, with composition of Ba4Ni2-xCoxFe36O60 (x=0.2, 0.4, 0.6, 0.8), were prepared by a conventional ceramic method. Saturation magnetization (4πMs), coercivity (Hc), and Curie temperature (Tc) were investigated. Anisotropy constant (K1) was calculated by fitting the magnetization curve (M-H) according to the law of approach to saturation, and anisotropy field (Ha) was calculated accordingly. The results reveal that all the samples possess the U-type hexagonal crystallographic structure. With increasing cobalt substitution content (x), the lattice parameters (a and c) almost remain the same owing to the similar radii of Ni2+ (0.72 Å) Co2+ (0.74 Å) ions. 4πMs goes up, while Hc Hc shows an opposite trend. K1 and Ha monotonously decrease resulting from that cobalt substitution weakens the c-axis orientation. Additionally, Tc increases from 467 °C to 484 °C.
Macroscopic behavior and microscopic magnetic properties of nanocarbon
NASA Astrophysics Data System (ADS)
Lähderanta, E.; Ryzhov, V. A.; Lashkul, A. V.; Galimov, D. M.; Titkov, A. N.; Matveev, V. V.; Mokeev, M. V.; Kurbakov, A. I.; Lisunov, K. G.
2015-06-01
Here are presented investigations of powder and glass-like samples containing carbon nanoparticles, not intentionally doped and doped with Ag, Au and Co. The neutron diffraction study reveals an amorphous structure of the samples doped with Au and Co, as well as the magnetic scattering due to a long-range FM order in the Co-doped sample. The composition and molecular structure of the sample doped with Au is clarified with the NMR investigations. The temperature dependence of the magnetization, M (T), exhibits large irreversibility in low fields of B=1-7 mT. M (B) saturates already above 2 T at high temperatures, but deviates from the saturation behavior below 50 (150 K). Magnetic hysteresis is observed already at 300 K and exhibits a power-law temperature decay of the coercive field, Bc (T). The macroscopic behavior above is typical of an assembly of partially blocked magnetic nanoparticles. The values of the saturation magnetization, Ms, and the blocking temperature, Tb, are obtained as well. However, the hysteresis loop in the Co-doped sample differs from that in other samples, and the values of Bc and Ms are noticeably increased.
Magnetism of Amorphous and Nano-Crystallized Dc-Sputter-Deposited MgO Thin Films
Mahadeva, Sreekanth K.; Fan, Jincheng; Biswas, Anis; Sreelatha, K.S.; Belova, Lyubov; Rao, K.V.
2013-01-01
We report a systematic study of room-temperature ferromagnetism (RTFM) in pristine MgO thin films in their amorphous and nano-crystalline states. The as deposited dc-sputtered films of pristine MgO on Si substrates using a metallic Mg target in an O2 containing working gas atmosphere of (N2 + O2) are found to be X-ray amorphous. All these films obtained with oxygen partial pressure (PO2) ~10% to 80% while maintaining the same total pressure of the working gas are found to be ferromagnetic at room temperature. The room temperature saturation magnetization (MS) value of 2.68 emu/cm3 obtained for the MgO film deposited in PO2 of 10% increases to 9.62 emu/cm3 for film deposited at PO2 of 40%. However, the MS values decrease steadily for further increase of oxygen partial pressure during deposition. On thermal annealing at temperatures in the range 600 to 800 °C, the films become nanocrystalline and as the crystallite size grows with longer annealing times and higher temperature, MS decreases. Our study clearly points out that it is possible to tailor the magnetic properties of thin films of MgO. The room temperature ferromagnetism in MgO films is attributed to the presence of Mg cation vacancies. PMID:28348346
NASA Astrophysics Data System (ADS)
Mottaghi, N.; Seehra, M. S.; Trappen, R.; Kumari, S.; Huang, Chih-Yeh; Yousefi, S.; Cabrera, G. B.; Romero, A. H.; Holcomb, M. B.
2018-05-01
Experimental investigations of the magnetic dead layer in 7.6 nm thick film of La0.7Sr0.3MnO3 (LSMO) are reported. The dc magnetization (M) measurements for a sample cooled to T = 5 K in applied field H = 0 reveal the presence of negative remanent magnetization (NRM) in the M vs. H (magnetic field) measurements as well as in the M vs. T measurements in H = 50 Oe and 100 Oe. The M vs. T data in ZFC (zero-field-cooled) and FC (field-cooled) protocols are used to determine the blocking temperature TB in different H. Isothermal hysteresis loops at different T are used to determine the temperature dependence of saturation magnetization (MS), remanence (MR) and coercivity HC. The MS vs. T data are fit to the Bloch law, MS (T) = M0 (1 - BT 3/2), showing a good fit for T < 100 K and yielding the nearest-neighbor exchange constant J/kB ≅ 18 K. The variations of TB vs. H and HC vs. T are well described by the model often used for randomly oriented magnetic nanoparticles with magnetic domain diameter ≈ 9 nm present in the dead-layer of thickness d =1.4 nm. Finally, the data available from literature on the thickness (D) variation of Curie temperature (TC) and MS of LSMO films grown under 200, 150, and 0.38 mTorr pressures of O2 are analyzed in terms of the finite-size scaling, with MS vs. D data fit to MS (D) = MS(b)(1-d/D) yielding the dead layer thickness d = 1.1 nm, 1.4 nm and 2.4 nm respectively. Brief discussion on the significance of these results is presented.
Berger, Thomas; Adamczyk-Sowa, Monika; Csépány, Tünde; Fazekas, Franz; Hojs Fabjan, Tanja; Horáková, Dana; Illes, Zsolt; Klimová, Eleonóra; Leutmezer, Fritz; Rejdak, Konrad; Rozsa, Csilla; Šega Jazbec, Saša; Szilasiová, Jarmila; Turčáni, Peter; Vachová, Marta; Vécsei, László; Havrdová, Eva
2018-01-01
Multiple sclerosis (MS) experts in Europe are facing rapidly rising demands of excellence due to the increasing complexity of MS therapy and management. A central European expert board of MS experts met to identify needs and obstacles with respect to raising quality of MS care in central and Eastern European countries. There are substantial variations across countries regarding delivery of care and its cost structure, as well as access to treatment. To date, Eastern European countries are often less able to afford reimbursement of immunomodulatory agents than Western countries. Overall, approximately 40% of working-age patients are not working due to MS. Costs rise steeply with increasing disability; indirect costs constitute the bulk of the financial burden in patients with severe MS. Magnetic resonance imaging (MRI) assessment is meanwhile obligatory as the diagnostic interface in the management of MS patients. Recommended measures directed at improving quality of care include the collection of patient data in registries, enhanced education of healthcare professionals, implementation of national strategies aiming at reducing regional variation, optimization of approval processes, and removal of administrative barriers. Local partnerships with authorities such as those that represent the interests of employees can contribute to leverage the importance of epidemiological data. The need for education extends to (neuro)radiologists who are responsible for reporting MRI findings in expert quality. Dissemination of the Magnetic Resonance Imaging in MS (MAGNIMS) protocol would be an important step in this context. Also, clinical freedom of choice is rated as essential. Physicians should have access to a range of treatment options due to the complexity of disease. Guidelines such as the upcoming EAN-ECTRIMS clinical practice guideline also aim at providing a basis for argumentation in negotiations with national health authorities. PMID:29511382
Physical and electrical properties of melt-spun Fe-Si (3–8 wt%) soft magnetic ribbons
Overman, Nicole R.; Jiang, Xiujuan; Kukkadapu, Ravi K.; ...
2017-12-13
Fe-Si alloys ranging from 3 to 8 wt% Si were rapidly solidified using melt spinning. Wheel speeds of 30 m/s and 40 m/s were employed to vary cooling rates. Mössbauer spectroscopic studies indicated the Si content significantly influenced the number of Fe sites, relative abundance of various Fe species, and internal magnetic fields/structural environments. Wheel speed altered Fe speciation only in the 3 wt% sample. Scanning electron microscopy confirmed that increasing the wheel speed refined both the ribbon thickness and grain size. Electron backscatter diffraction results suggest tailoring melt spinning process parameters and alloy chemistry may offer the ability tomore » manipulate {001} texture development. In conclusion, electrical resistivity measurements were observed to increase in response to elevated Si content. Increased hardness was correlated to elevated Si content and wheel speed.« less
Physical and electrical properties of melt-spun Fe-Si (3–8 wt.%) soft magnetic ribbons
DOE Office of Scientific and Technical Information (OSTI.GOV)
Overman, Nicole R.; Jiang, Xiujuan; Kukkadapu, Ravi K.
Fe-Si alloys ranging from 3 to 8 wt% Si were rapidly solidified using melt spinning. Wheel speeds of 30 m/s and 40 m/s were employed to vary cooling rates. Mössbauer spectroscopic studies indicated the Si content significantly influenced the number of Fe sites, relative abundance of various Fe species, and internal magnetic fields/structural environments. Wheel speed altered Fe speciation only in the 3 wt% sample. Scanning electron microscopy confirmed that increasing the wheel speed refined both the ribbon thickness and grain size. Electron backscatter diffraction results suggest tailoring melt spinning process parameters and alloy chemistry may offer the ability tomore » manipulate {001} texture development. Electrical resistivity measurements were observed to increase in response to elevated Si content. Increased hardness was correlated to elevated Si content and wheel speed.« less
Vijaya, J Judith; Bououdina, M
2016-01-01
Ni-doped ZnFe₂O₄(Ni(x)Zn₁₋xFe₂O₄; x = 0.0 to 0.5) nanoparticles were synthesized by a simple microwave combustion method. The X-ray diffraction confirms the presence of cubic spinel ZnFe₂O₄for all compositions. The lattice parameter decreases with an increase in Ni content resulting in the reduction of lattice strain. High resolution scanning electron microscope images revealed that the as-prepared samples are crystalline with particle size distribution in 40-50 nm range. Optical properties were determined by UV-Visible diffuse reflectance and photoluminescence spectroscopy respectively. The saturation magnetization (Ms) shows the super paramagnetic nature of the sample for x = 0.0-0.2, whereas for x = 0.3-0.5, it shows ferromagnetic nature. The Ms value is 1.638 emu/g for pure ZnFe₂O₄ sample and it increases with increase in Ni content.
Physical and electrical properties of melt-spun Fe-Si (3–8 wt%) soft magnetic ribbons
DOE Office of Scientific and Technical Information (OSTI.GOV)
Overman, Nicole R.; Jiang, Xiujuan; Kukkadapu, Ravi K.
Fe-Si alloys ranging from 3 to 8 wt% Si were rapidly solidified using melt spinning. Wheel speeds of 30 m/s and 40 m/s were employed to vary cooling rates. Mössbauer spectroscopic studies indicated the Si content significantly influenced the number of Fe sites, relative abundance of various Fe species, and internal magnetic fields/structural environments. Wheel speed altered Fe speciation only in the 3 wt% sample. Scanning electron microscopy confirmed that increasing the wheel speed refined both the ribbon thickness and grain size. Electron backscatter diffraction results suggest tailoring melt spinning process parameters and alloy chemistry may offer the ability tomore » manipulate {001} texture development. In conclusion, electrical resistivity measurements were observed to increase in response to elevated Si content. Increased hardness was correlated to elevated Si content and wheel speed.« less
NASA Astrophysics Data System (ADS)
Othman, H. A.; Eltabey, M. M.; Ibrahim, Samia. E.; El-Deen, L. M. Sharaf; Elkholy, M. M.
2017-02-01
Co-ferrites nanoparticles that have been prepared by the co-precipitation method were added to sodium borosilicate (Na2O-B2O3-SiO2) glass matrix by the solid solution method and they were characterized using X-ray diffraction (XRD), transmission electron microscopy (TEM), Fourier transform infrared (FTIR) and magnetization measurements. (XRD) revealed the formation of the Co-ferrite magnetic crystalline phase embedded in an amorphous matrix in all the samples. The investigated samples by (TEM) showed the formation of the cobalt ferrite nanoparticles with a spherical shape and highly monodispersed with an average size about 13 nm. IR data revealed that the BO3 and BO4 are the main structural units of these samples network. IR spectra of the investigated samples showed the characteristic vibration bands of Co-ferrite. Composition and frequency dependent dielectric properties of the prepared samples were measured at room temperature in the frequency range 100-100 kHz. The conductivity was found to increase with increasing cobalt ferrite content. The variations of conductivity and dielectric properties with frequency and composition were discussed. Magnetic hysteresis loops were traced at room temperature using VSM and values of saturation magnetization MS and coercive field HC were determined. The obtained results revealed that a ferrimagnetic behavior were observed and as Co-ferrite concentration increases the values of MS and HC increase from 2.84 to 8.79 (emu/g) and from 88.4 to 736.3 Oe, respectively.
First results from the LIFE project: discovery of two magnetic hot evolved stars
NASA Astrophysics Data System (ADS)
Martin, A. J.; Neiner, C.; Oksala, M. E.; Wade, G. A.; Keszthelyi, Z.; Fossati, L.; Marcolino, W.; Mathis, S.; Georgy, C.
2018-04-01
We present the initial results of the Large Impact of magnetic Fields on the Evolution of hot stars (LIFE) project. The focus of this project is the search for magnetic fields in evolved OBA giants and supergiants with visual magnitudes between 4 and 8, with the aim to investigate how the magnetic fields observed in upper main-sequence (MS) stars evolve from the MS until the late post-MS stages. In this paper, we present spectropolarimetric observations of 15 stars observed using the ESPaDOnS instrument of the Canada-France-Hawaii Telescope. For each star, we have determined the fundamental parameters and have used stellar evolution models to calculate their mass, age, and radius. Using the least-squared deconvolution technique, we have produced averaged line profiles for each star. From these profiles, we have measured the longitudinal magnetic field strength and have calculated the detection probability. We report the detection of magnetic fields in two stars of our sample: a weak field of Bl = 1.0 ± 0.2 G is detected in the post-MS A5 star 19 Aur and a stronger field of Bl = -230 ± 10 G is detected in the MS/post-MS B8/9 star HR 3042.
Exchange-coupled Fe3O4/CoFe2O4 nanoparticles for advanced magnetic hyperthermia
NASA Astrophysics Data System (ADS)
Robles, J.; Das, R.; Glassell, M.; Phan, M. H.; Srikanth, H.
2018-05-01
We report a systematic study of the effects of core and shell size on the magnetic properties and heating efficiency of exchange-coupled Fe3O4/CoFe2O4 core/shell nanoparticles. The nanoparticles were synthesized using thermal decomposition of organometallic precursors. Transmission electron microscopy (TEM) confirmed the formation of spherical Fe3O4 and Fe3O4/CoFe2O4 nanoparticles. Magnetic measurements showed high saturation magnetization for the nanoparticles at room temperature. Increasing core diameter (6.4±0.7, 7.8±0.1, 9.6±1.2 nm) and/or shell thickness (˜1, 2, 4 nm) increased the coercive field (HC), while an optimal value of saturation magnetization (MS) was achieved for the Fe3O4 (7.8±0.1nm)/CoFe2O4 (2.1±0.1nm) nanoparticles. Magnetic hyperthermia measurements indicated a large increase in specific absorption rate (SAR) for 8.2±1.1 nm Fe3O4/CoFe2O4 compared to Fe3O4 nanoparticles of same size. The SAR of the Fe3O4/CoFe2O4 nanoparticles increased from 199 to 461 W/g for 800 Oe as the thickness of the CoFe2O4 shell was increased from 0.9±0.5 to 2.1±0.1 nm. The SAR enhancement is attributed to a combination of the large MS and the large HC. Therefore, these Fe3O4/CoFe2O4 core/shell nanoparticles can be a good candidate for advanced hyperthermia application.
Preparation and oil absorption properties of magnetic melamine sponge
NASA Astrophysics Data System (ADS)
Lei, LUO; Jia-qi, HU; Na, LV
2017-12-01
The magnetic melamine sponge (MS-Fe3O4) with magnetic response and high hydrophobicity was fabricated by two-step method. First, the magnetic nano-particles were fixed on the skeleton of melamine sponge (MS) using 3-hydroxytyramine hydrochloride and 1-dodecanethiol, then hydrophobicity modified with octadecyltrichlorosilane (OTS). The structures and chemical compositions of MS and MS-Fe3O4 were characterized by Fourier transform infrared spectroscopy (FT-IR), X-ray diffraction (XRD) and scanning electron microscopy (SEM). The wettability of the sample was obtained by using contact angle analysis system. MS-Fe3O4 endowed with outstanding selectivity and excellent oil absorption capacities, which can be widely used in absorbing various sorts of oil. The oil absorption capacities for crude oil, diesel oil, lubricating oil, soybean oil and peanut oil were 71g/g, 51g/g, 62g/g, 54g/g, 57g/g. In addition, MS-Fe3O4 showed excellent recyclability which can be forecasted as an ideal candidate for oil-water separation.
[Disease concept, etiology and mechanisms of multiple sclerosis].
Kira, Jun-Ichi
2014-11-01
Multiple sclerosis (MS) is an inflammatory demyelinating disease of the central nervous system(CNS). MS is assumed to be caused by a complex interplay between genes and environments. Autoimmune mechanisms targeting CNS myelin has long been proposed, yet it has not been proved. Th17 cells producing interleukin-17 and Th1 cells producing interferon-gamma are postulated to play major roles in initiating inflammation while regulatory T cell functions are dampened. The forth nationwide survey of MS in Japan revealed that MS prevalence showed four-folds increase over 30 years and the increase was especially prominent in female. Thus, westernized life style and improved sanitation are suspected to increase MS susceptibility. Genome-wide association studies in Western MS patients disclosed more than 100 disease-susceptibility genes, most of which are immune-related genes. It therefore supports immune-mediated mechanisms to be operative. Detailed magnetic resonance imaging studies revealed an early atrophy of the cerebral gray matter where T cell infiltration is pathologically scarce. Therefore, neurodegenerative process also takes place in the early course beside neuroinflammation.
A study on magneto-optic properties of CoxMg1-xFe2O4 nanoferrofluids
NASA Astrophysics Data System (ADS)
Karthick, R.; Ramachandran, K.; Srinivasan, R.
2018-04-01
Nanoparticles of CoxMg1-xFe2O4 (x = 0.1, 0.5, 0.9) were synthesized using chemical co-precipitation method. Characterization by X-ray diffraction technique confirmed the formation of cubic crystalline structure and the crystallite size of the samples obtained using Debye-Scherrer approximation were found to increase with increasing cobalt substitution. Surface morphology and the Chemical composition of the samples were visualized using scanning electron microscope (SEM) with energy dispersive analysis of X-rays (EDAX). Room temperature magnetic parameters of the nanoparticles by vibrating sample magnetometer (VSM) revealed the magnetic properties such as Saturation magnetization (Ms), Remanent magnetization (Mr) and Coercive field (Hc) found to increase with increasing cobalt substitution. Faraday rotation measurements on CoxMg1-xFe2O4 ferrofluids exhibited increase in rotation with cobalt substitution. Further, there is an increase in Faraday rotation with increasing magnetic field for all the samples.
Employment Trends in High-Technology Occupations.
1985-07-01
Projected Growth as a Percentage of 1980 Employment, 1981-1985 .......... 10 7. Projected Employment in Magnetic Fusion Energy Occupations Funded by the...demand in a particular industry, personnel demand for a special activity--magnetic fusion energy (Finn, Hansen, & Harr, 1981)--was examined by Oak Ridge...Magnetic Fusion Energy Occupations Funded by the Department of Energy 1981-2000 Full-Time Person-Years 1981 1990 2000 Occupation BS/MS PhD BS/MS PhD BS/MS
NASA Astrophysics Data System (ADS)
Grison, H.; Petrovsky, E.; Kapicka, A.
2016-12-01
In rock, soil and environmental studies dealing with magnetic methods, the frequency-dependent magnetic susceptibility (κFD%) is parameter generally accepted as a tool for identification of ultrafine superparamagnetic (SP) particles. This parameter became an indicator of pedogenic magnetic fraction (increased pedogenesis). Despite the number of studies using this parameter, knowledge about threshold values of κFD% is not clear enough and this parameter may be misinterpreted. Moreover, in strongly magnetic soils, magnetic signal of the SP (mostly pedogenic) minerals may be masked by dominant lithological signal, carried by coarse-grain mineral fraction; therefore, influence of pedogenesis is hard to detect. The aim of this contribution is to compare results in determination of ultrafine SP magnetic particles in soils determined using different instruments: (a) Bartington MS2B dual-frequency meter, and (b) more sensitive AGICO Kappameter MFK1-FA. The values of the κFD % obtained by the Bartington MS2B varied from 0.9 to 5.8% (mass-specific magnetic susceptibility from 119 to 1533 × 10-8 m3/kg) while the AGICO MFK1-FA varied from 3.7 to 8.2% (mass-specific magnetic susceptibility from 295 to 1843 × 10-8 m3/kg). Although both instruments suggest significant portion of SP magnetic particles, the results can't be interpreted using the generally accepted threshold values based on Bartington data. However, our results suggest that relation between the mass-specific magnetic susceptibility and κFD% along whole soil profile may serve as suitable tool in discriminating between lithogenic and pedogenic control of magnetic fraction in the soil profile. Moreover, we propose new concept of identification of SP particles, based on field-dependent magnetic susceptibility. Its behaviour shows distinct features with significant change at amplitudes of about 100 A/m. Below this value, susceptibility decreases with increasing amplitude, reflecting saturation of magnetization due to rotation of SP magnetic moments, while above 100 A/m it increases due to magnetization of MD particles.
NASA Astrophysics Data System (ADS)
Yeung, Sai Ho; Pradhan, Raunaq; Feng, Xiaohua; Zheng, Yuanjin
2015-09-01
Recently, the design concept of magnetic resonant coupling has been adapted to electromagnetic therapy applications such as non-invasive radiofrequency (RF) stimulation. This technique can significantly increase the electric field radiated from the magnetic coil at the stimulation target, and hence enhancing the current flowing through the nerve, thus enabling stimulation. In this paper, the developed magnetic resonant coupling (MRC) stimulation, magnetic stimulation (MS) and transcutaneous electrical nerve stimulation (TENS) are compared. The differences between the MRC RF stimulation and other techniques are presented in terms of the operating mechanism, ex-vivo tissue voltage measurement and electromagnetic simulation analysis. The ev-vivo tissue voltage measurement experiment is performed on the compared devices based on measuring the voltage induced by electromagnetic induction at the tissue. The focusing effect, E field and voltage induced across the tissue, and the attenuation due to the increase of separation between the coil and the target are analyzed. The electromagnetic stimulation will also be performed to obtain the electric field and magnetic field distribution around the biological medium. The electric field intensity is proportional to the induced current and the magnetic field is corresponding to the electromagnetic induction across the biological medium. The comparison between the MRC RF stimulator and the MS and TENS devices revealed that the MRC RF stimulator has several advantages over the others for the applications of inducing current in the biological medium for stimulation purposes.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Yeung, Sai Ho; Pradhan, Raunaq; Feng, Xiaohua
Recently, the design concept of magnetic resonant coupling has been adapted to electromagnetic therapy applications such as non-invasive radiofrequency (RF) stimulation. This technique can significantly increase the electric field radiated from the magnetic coil at the stimulation target, and hence enhancing the current flowing through the nerve, thus enabling stimulation. In this paper, the developed magnetic resonant coupling (MRC) stimulation, magnetic stimulation (MS) and transcutaneous electrical nerve stimulation (TENS) are compared. The differences between the MRC RF stimulation and other techniques are presented in terms of the operating mechanism, ex-vivo tissue voltage measurement and electromagnetic simulation analysis. The ev-vivo tissuemore » voltage measurement experiment is performed on the compared devices based on measuring the voltage induced by electromagnetic induction at the tissue. The focusing effect, E field and voltage induced across the tissue, and the attenuation due to the increase of separation between the coil and the target are analyzed. The electromagnetic stimulation will also be performed to obtain the electric field and magnetic field distribution around the biological medium. The electric field intensity is proportional to the induced current and the magnetic field is corresponding to the electromagnetic induction across the biological medium. The comparison between the MRC RF stimulator and the MS and TENS devices revealed that the MRC RF stimulator has several advantages over the others for the applications of inducing current in the biological medium for stimulation purposes.« less
Petr, Jan; Schramm, Georg; Hofheinz, Frank; Langner, Jens; van den Hoff, Jörg
2014-10-01
To estimate the relaxation time changes during Q2TIPS bolus saturation caused by magnetization transfer effects and to propose and evaluate an extended model for perfusion quantification which takes this into account. Three multi inversion-time pulsed arterial spin labeling sequences with different bolus saturation duration were acquired for five healthy volunteers. Magnetization transfer exchange rates in tissue and blood were obtained from control image saturation recovery. Cerebral blood flow (CBF) obtained using the extended model and the standard model was compared. A decrease of obtained CBF of 6% (10%) was observed in grey matter when the duration of bolus saturation increased from 600 to 900 ms (1200 ms). This decrease was reduced to 1.6% (2.8%) when the extended quantification model was used. Compared with the extended model, the standard model underestimated CBF in grey matter by 9.7, 15.0, and 18.7% for saturation durations 600, 900, and 1200 ms, respectively. Results for simulated single inversion-time data showed 5-16% CBF underestimation depending on blood arrival time and bolus saturation duration. Magnetization transfer effects caused by bolus saturation pulses should not be ignored when performing quantification as they can cause appreciable underestimation of the CBF. Copyright © 2013 Wiley Periodicals, Inc.
Investigation of temperature dependent magnetic hyperthermia in Fe3O4 ferrofluids
NASA Astrophysics Data System (ADS)
Nemala, Humeshkar Bhaskar
Magnetic nanoparticles (MNPs) of Fe3O4 and gamma-Fe2O3 have been exploited in the biomedical fields for imaging, targeted drug delivery and magnetic hyperthermia. Magnetic hyperthermia (MHT), the production of heat using ferrofluids, colloidal suspensions of MNPs, in an external AC magnetic field (amplitude, 100-500 Oe and frequency 50 kHz -1MHz), has been explored by many researchers, both in vitro and in vivo, as an alternative viable option to treat cancer. The heat energy generated by Neel and Brownian relaxation processes of the internal magnetic spins could be used to elevate local tissue temperature to about 46 ˚C to arrest cancerous growth. MHT, due to its local nature of heating, when combined with other forms of treatment such as chemotherapy and/or radiation therapy, it could become an effective therapy for cancer treatment. The efficiency of heat production in MHT is quantified by specific absorption rate (SAR), defined as the power output per gram of the MNPs used. In this thesis, ferrofluids consisting of Fe3O4 MNPs of three different sizes (˜ 10 - 13 nm) coated with two different biocompatible surfactants, dextran and polyethylene glycol (PEG), have been investigated. The structural and magnetic characterization of the MNPs were done using XRD, TEM, and DC magnetization measurements. While XRD revealed the crystallite size, TEM provided the information about morphology and physical size distribution of the MNPs. Magnetic measurements of M-vs-H curves for ferrofluids provided information about the saturation magnetization (Ms) and magnetic core size distribution of MNPs. Using MHT measurements, the SAR has been studied as a function of temperature, taking into account the heat loss due to non-adiabatic nature of the experimental set-up. The observed SAR values have been interpreted using the theoretical framework of linear response theory (LRT). We found the SAR values depend on particle size distribution of MNPs, Ms (65-80 emu/g) and the magnetic anisotropy energy density (K: 12-20 KJ/m3), as well as the amplitude and frequency of the applied AC field (amplitude, 150-250 Oe and frequency, 180-380 kHz). In general, Ms and magnetic core diameter of MNPs increased with the increase in particle size. However, our detailed analysis of MHT data show that although SAR increased with the particle size, the polydispersity of the particles as well as the magnetic anisotropy energy density significantly affected the SAR values. Dextran and PEG coatings essentially yielded similar SAR values ~ 100 W/g using ferrofluids of Fe3O4 MNPs with an average crystallite size of 11.6 +/- 2.1 nm, in AC field of 245 Oe and 375 KHz.
In Situ Magnetic Susceptibility Variations at Two Contaminated Sites: Brandywine, MD and Bemidji, MN
NASA Astrophysics Data System (ADS)
Donaldson, Y. Y.; Kessouri, P.; Ntarlagiannis, D.; Johnson, T. C.; Day-Lewis, F. D.; Johnson, C. D.; Bekins, B. A.; Slater, L. D.
2017-12-01
Geophysical methods are widely used monitoring tools for investigating subsurface processes. Compared to more traditional methods, they are low cost and minimally invasive. Magnetic susceptibility (MS) is a geophysical technique particularly sensitive to the presence of ferri/ ferro-magnetic particles such as iron oxides (e.g., magnetite, hematite and goethite). These oxides can be formed through microbially mediated redox reactions, inducing changes in the soil properties that can be observed by MS measurements. Monitoring MS changes over time provides indications of iron mineral transformations in the ground. These transformations are of particular interest for the characterization of contaminated sites. We acquired borehole MS measurements from two contaminated sites: Brandywine, MD and Bemidji, MN. Active remediation was applied at Brandywine, whereas natural attenuation has been geophysically monitored at Bemidji since 2011 using MS log measurements. High MS values were observed at both sites within the contaminated area only. We hypothesize that this is due to iron reducing bacteria reducing Fe-(III) to Fe-(II) and utilizing contaminants and/or amendments injected as a carbon source. At Bemidji, elevated MS readings were observed in the smear zone and correlate to the presence of magnetite. Furthermore, time-lapse MS observations at Bemidji indicate a decay in signal amplitude over time suggesting further redox transformation into less magnetic particles. For both field examples presented here, we observe variations in magnetic susceptibility within the contaminated areas that can be linked with redox reactions and mineral transformations occurring during the degradation of organic contaminants.
VISUALIZING IRON IN MULTIPLE SCLEROSIS
Bagnato, Francesca; Hametner, Simon; Welch, Edward Brian
2012-01-01
Magnetic resonance imaging (MRI) protocols that are designed to be sensitive to iron typically take advantage of (1) iron effects on the relaxation of water protons and/or (2) iron-induced local magnetic field susceptibility changes. Increasing evidence sustains the notion that imaging iron in brain of patients with multiple sclerosis (MS) may add some specificity toward the identification of the disease pathology. The present review summarizes currently reported in vivo and post mortem MRI evidence of (1) iron detection in white matter and grey matter of MS brains, (2) pathological and physiological correlates of iron as disclosed by imaging and (3) relations between iron accumulation and disease progression as measured by clinical metrics. PMID:23347601
NASA Technical Reports Server (NTRS)
Shastry, Rohit; Huang, Wensheng; Haag, Thomas W.; Kamhawi, Hani
2013-01-01
NASA is presently developing a high-power, high-efficiency, long-lifetime Hall thruster for the Solar Electric Propulsion Technology Demonstration Mission. In support of this task, studies have been performed on the 20-kW NASA-300M Hall thruster to aid in the overall design process. The ability to incorporate magnetic shielding into a high-power Hall thruster was also investigated with the NASA- 300MS, a modified version of the NASA-300M. The inclusion of magnetic shielding would allow the thruster to push existing state-of-the-art technology in regards to service lifetime, one of the goals of the Technology Demonstration Mission. Langmuir probe measurements were taken within the discharge channels of both thrusters in order to characterize differences at higher power levels, as well as validate ongoing modeling efforts using the axisymmetric code Hall2De. Flush-mounted Langmuir probes were also used within the channel of the NASA-300MS to verify that magnetic shielding was successfully applied. Measurements taken from 300 V, 10 kW to 600 V, 20 kW have shown plasma potentials near anode potential and electron temperatures of 4 to 12 eV at the walls near the thruster exit plane of the NASA-300MS, verifying magnetic shielding and validating the design process at this power level. Channel centerline measurements on the NASA-300M from 300 V, 10 kW to 500 V, 20 kW show the electron temperature peak at approximately 0.1 to 0.2 channel lengths upstream of the exit plane, with magnitudes increasing with discharge voltage. The acceleration profiles appear to be centered about the exit plane with a width of approximately 0.3 to 0.4 channel lengths. Channel centerline measurements on the NASA-300MS were found to be more challenging due to additional probe heating. Ionization and acceleration zones appeared to move downstream on the NASA-300MS compared to the NASA-300M, as expected based on the shift in peak radial magnetic field. Additional measurements or alternative diagnostics will be needed to verify peak electron temperatures in the NASA-300MS and compare them with model predictions.
NASA Astrophysics Data System (ADS)
Sato, Aya; Torii, Tetsuya; Iwahashi, Masakuni; Itoh, Yuji; Iramina, Keiji
2014-05-01
The present study analyzed the effects of monophasic magnetic stimulation to the motor cortex. The effects of magnetic stimulation were evaluated by analyzing the motor evoked potentials (MEPs). The amplitude and latency of MEPs on the abductor pollicis brevis muscle were used to evaluate the effects of repetitive magnetic stimulation. A figure eight-shaped flat coil was used to stimulate the region over the primary motor cortex. The intensity of magnetic stimulation was 120% of the resting motor threshold, and the frequency of magnetic stimulation was 0.1 Hz. In addition, the direction of the current in the brain was posterior-anterior (PA) or anterior-posterior (AP). The latency of MEP was compared with PA and AP on initial magnetic stimulation. The results demonstrated that a stimulus in the AP direction increased the latency of the MEP by approximately 2.5 ms. MEP amplitude was also compared with PA and AP during 60 magnetic stimulations. The results showed that a stimulus in the PA direction gradually increased the amplitude of the MEP. However, a stimulus in the AP direction did not modulate the MEP amplitude. The average MEP amplitude induced from every 10 magnetic pulses was normalized by the average amplitude of the first 10 stimuli. These results demonstrated that the normalized MEP amplitude increased up to approximately 150%. In terms of pyramidal neuron indirect waves (I waves), magnetic stimulation inducing current flowing backward to the anterior preferentially elicited an I1 wave, and current flowing forward to the posterior elicited an I3 wave. It has been reported that the latency of the I3 wave is approximately 2.5 ms longer than the I1 wave elicitation, so the resulting difference in latency may be caused by this phenomenon. It has also been reported that there is no alteration of MEP amplitude at a frequency of 0.1 Hz. However, this study suggested that the modulation of MEP amplitude depends on stimulation strength and stimulation direction.
Costo, Rocio; Bello, Valentina; Robic, Caroline; Port, Marc; Marco, Jose F; Puerto Morales, M; Veintemillas-Verdaguer, Sabino
2012-01-10
A considerable increase in the saturation magnetization, M(s) (40%), and initial susceptibility of ultrasmall (<5 nm) iron oxide nanoparticles prepared by laser pyrolysis was obtained through an optimized acid treatment. Moreover, a significant enhancement in the colloidal properties, such as smaller aggregate sizes in aqueous media and increased surface charge densities, was found after this chemical protocol. The results are consistent with a reduction in nanoparticle surface disorder induced by a dissolution-recrystallization mechanism.
NASA Astrophysics Data System (ADS)
Kumari, Mukesh; Bhatnagar, Mukesh Chander
2018-05-01
Cobalt ferrite (CFO) has been synthesized in the form of nanoparticles (NPs) through sol-gel auto-combustion method. The prepared NPs of CFO were sintered for four hours at various temperatures from 300°C to 900°C. The physical properties of the sintered samples have been optimized using X-ray diffraction (XRD), Raman spectroscopy and physical properties measurement system (PPMS). The XRD and Raman studies have confirmed the cubic spinel phase formation of CFO NPs. XRD results showed that as we increase the sintering temperature the crystallite size of particles increases. Whereas the magnetic studies revealed that the saturation magnetization (MS) increases while the coercivity (HC) of nanoparticles decreases with increase of sintering temperature.
Resting-state connectivity of pre-motor cortex reflects disability in multiple sclerosis.
Dogonowski, A-M; Siebner, H R; Soelberg Sørensen, P; Paulson, O B; Dyrby, T B; Blinkenberg, M; Madsen, K H
2013-11-01
To characterize the relationship between motor resting-state connectivity of the dorsal pre-motor cortex (PMd) and clinical disability in patients with multiple sclerosis (MS). A total of 27 patients with relapsing-remitting MS (RR-MS) and 15 patients with secondary progressive MS (SP-MS) underwent functional resting-state magnetic resonance imaging. Clinical disability was assessed using the Expanded Disability Status Scale (EDSS). Independent component analysis was used to characterize motor resting-state connectivity. Multiple regression analysis was performed in SPM8 between the individual expression of motor resting-state connectivity in PMd and EDSS scores including age as covariate. Separate post hoc analyses were performed for patients with RR-MS and SP-MS. The EDSS scores ranged from 0 to 7 with a median score of 4.3. Motor resting-state connectivity of left PMd showed a positive linear relation with clinical disability in patients with MS. This effect was stronger when considering the group of patients with RR-MS alone, whereas patients with SP-MS showed no increase in coupling strength between left PMd and the motor resting-state network with increasing clinical disability. No significant relation between motor resting-state connectivity of the right PMd and clinical disability was detected in MS. The increase in functional coupling between left PMd and the motor resting-state network with increasing clinical disability can be interpreted as adaptive reorganization of the motor system to maintain motor function, which appears to be limited to the relapsing-remitting stage of the disease. © 2013 John Wiley & Sons A/S.
Magnetosonic solitons in space plasmas: dark or bright solitons?
NASA Astrophysics Data System (ADS)
Pokhotelov, O. A.; Onishchenko, O. G.; Balikhin, M. A.; Stenflo, L.; Shukla, P. K.
2007-12-01
The nonlinear theory of large-amplitude magnetosonic (MS) waves in highβ space plasmas is revisited. It is shown that solitary waves can exist in the form of `bright' or `dark' solitons in which the magnetic field is increased or decreased relative to the background magnetic field. This depends on the shape of the equilibrium ion distribution function. The basic parameter that controls the nonlinear structure is the wave dispersion, which can be either positive or negative. A general dispersion relation for MS waves propagating perpendicularly to the external magnetic field in a plasma with an arbitrary velocity distribution function is derived.It takes into account general plasma equilibria, such as the Dory-Guest-Harris (DGH) or Kennel-Ashour-Abdalla (KA) loss-cone equilibria, as well as distributions with a power-law velocity dependence that can be modelled by κdistributions. It is shown that in a bi-Maxwellian plasma the dispersion is negative, i.e. the phase velocity decreases with an increase of the wavenumber. This means that the solitary solution in this case has the form of a `bright' soliton with the magnetic field increased. On the contrary, in some non-Maxwellian plasmas, such as those with ring-type ion distributions or DGH plasmas, the solitary solution may have the form of a magnetic hole. The results of similar investigations based on nonlinear Hall-MHD equations are reviewed. The relevance of our theoretical results to existing satellite wave observations is outlined.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Byrne, James; Klueglein, Nicole; Pearce, Carolyn I.
Despite the regular occurrence of both magnetite and iron-metabolizing bacteria in the same environments, it is currently unknown whether the iron(II) and iron(III) in magnetite can be cycled between different bacteria and whether or how magnetic properties are affected by this metabolic activity. We show through magnetic and spectroscopic measurements that the phototrophic Fe(II)-oxidizer Rhodopseudomonas palustris TIE-1 can oxidize solid-phase magnetite nanoparticles using light energy, leading to a decrease in the measured magnetic susceptibility (MS). This process likely occurs at the surface and is reversible in the dark by the Fe(III)-reducer Geobacter sulfurreducens resulting in an increase in MS. Thesemore » results show that iron ions bound in highly crystalline mineral magnetite are bioavailable as electron stores and electron sinks under varying environmental conditions, making magnetite a potential “biogeobattery” during day/night cycles. These findings are relevant for environmental studies and reinforce the impact of microbial redox processes on the global iron cycle.« less
Magnetic properties of Co/Ni grain boundaries after annealing
NASA Astrophysics Data System (ADS)
Coutts, Chris; Arora, Monika; Hübner, René; Heinrich, Bret; Girt, Erol
2018-05-01
Magnetic and microstructural properties of <111> textured Cu/N×[Co/Ni] films are studied as a function of the number of bilayer repeats N and annealing temperature. M(H) loop measurements show that coercivity, Hc, increases with annealing temperature and that the slope of the saturation curve at Hc has a larger reduction for smaller N. An increase of the magnetic anisotropy (Ku) to saturation magnetization (Ms) ratio after annealing N×[Co/Ni] with N < 15 only partially describes the increase to Hc. Energy-dispersive X-ray spectroscopy analyses performed in scanning transmission electron microscopy mode across cross-sections of as-deposited and annealed Cu/16×[Co/Ni] films show that Cu diffuses from the seed layer into grain boundaries of Co/Ni. Diffusion of Cu reduces exchange coupling (Hex) between the magnetic grains and explains the increase in Hc. Additionally, the difference in the slope of the M(H) curves at Hc between the thick (N = 16) and thin (N = 4) magnetic multilayers is due to Cu diffusion more effectively decoupling magnetic grains in the thinner multilayer.
Parallel Spectral Acquisition with an Ion Cyclotron Resonance Cell Array.
Park, Sung-Gun; Anderson, Gordon A; Navare, Arti T; Bruce, James E
2016-01-19
Mass measurement accuracy is a critical analytical figure-of-merit in most areas of mass spectrometry application. However, the time required for acquisition of high-resolution, high mass accuracy data limits many applications and is an aspect under continual pressure for development. Current efforts target implementation of higher electrostatic and magnetic fields because ion oscillatory frequencies increase linearly with field strength. As such, the time required for spectral acquisition of a given resolving power and mass accuracy decreases linearly with increasing fields. Mass spectrometer developments to include multiple high-resolution detectors that can be operated in parallel could further decrease the acquisition time by a factor of n, the number of detectors. Efforts described here resulted in development of an instrument with a set of Fourier transform ion cyclotron resonance (ICR) cells as detectors that constitute the first MS array capable of parallel high-resolution spectral acquisition. ICR cell array systems consisting of three or five cells were constructed with printed circuit boards and installed within a single superconducting magnet and vacuum system. Independent ion populations were injected and trapped within each cell in the array. Upon filling the array, all ions in all cells were simultaneously excited and ICR signals from each cell were independently amplified and recorded in parallel. Presented here are the initial results of successful parallel spectral acquisition, parallel mass spectrometry (MS) and MS/MS measurements, and parallel high-resolution acquisition with the MS array system.
Krewer, Carmen; Hartl, Sandra; Müller, Friedemann; Koenig, Eberhard
2014-06-01
To investigate short-term and long-term effects of repetitive peripheral magnetic stimulation (rpMS) on spasticity and motor function. Monocentric, randomized, double-blind, sham-controlled trial. Neurologic rehabilitation hospital. Patients (N=66) with severe hemiparesis and mild to moderate spasticity resulting from a stroke or a traumatic brain injury. The average time ± SD since injury for the intervention groups was 26 ± 71 weeks or 37 ± 82 weeks. rpMS for 20 minutes or sham stimulation with subsequent occupational therapy for 20 minutes, 2 times a day, over a 2-week period. Modified Tardieu Scale and Fugl-Meyer Assessment (arm score), assessed before therapy, at the end of the 2-week treatment period, and 2 weeks after study treatment. Additionally, the Tardieu Scale was assessed after the first and before the third therapy session to determine any short-term effects. Spasticity (Tardieu >0) was present in 83% of wrist flexors, 62% of elbow flexors, 44% of elbow extensors, and 10% of wrist extensors. Compared with the sham stimulation group, the rpMS group showed short-term effects on spasticity for wrist flexors (P=.048), and long-term effects for elbow extensors (P<.045). Arm motor function (rpMS group: median 5 [4-27]; sham group: median 4 [4-9]) did not significantly change over the study period in either group, whereas rpMS had a positive effect on sensory function. Therapy with rpMS increases sensory function in patients with severe limb paresis. The magnetic stimulation, however, has limited effect on spasticity and no effect on motor function. Copyright © 2014 American Congress of Rehabilitation Medicine. Published by Elsevier Inc. All rights reserved.
Effects of pulse duration on magnetostimulation thresholds
DOE Office of Scientific and Technical Information (OSTI.GOV)
Saritas, Emine U., E-mail: saritas@ee.bilkent.edu.tr; Department of Electrical and Electronics Engineering, Bilkent University, Bilkent, Ankara 06800; National Magnetic Resonance Research Center
Purpose: Medical imaging techniques such as magnetic resonance imaging and magnetic particle imaging (MPI) utilize time-varying magnetic fields that are subject to magnetostimulation limits, which often limit the speed of the imaging process. Various human-subject experiments have studied the amplitude and frequency dependence of these thresholds for gradient or homogeneous magnetic fields. Another contributing factor was shown to be number of cycles in a magnetic pulse, where the thresholds decreased with longer pulses. The latter result was demonstrated on two subjects only, at a single frequency of 1.27 kHz. Hence, whether the observed effect was due to the number ofmore » cycles or due to the pulse duration was not specified. In addition, a gradient-type field was utilized; hence, whether the same phenomenon applies to homogeneous magnetic fields remained unknown. Here, the authors investigate the pulse duration dependence of magnetostimulation limits for a 20-fold range of frequencies using homogeneous magnetic fields, such as the ones used for the drive field in MPI. Methods: Magnetostimulation thresholds were measured in the arms of six healthy subjects (age: 27 ± 5 yr). Each experiment comprised testing the thresholds at eight different pulse durations between 2 and 125 ms at a single frequency, which took approximately 30–40 min/subject. A total of 34 experiments were performed at three different frequencies: 1.2, 5.7, and 25.5 kHz. A solenoid coil providing homogeneous magnetic field was used to induce stimulation, and the field amplitude was measured in real time. A pre-emphasis based pulse shaping method was employed to accurately control the pulse durations. Subjects reported stimulation via a mouse click whenever they felt a twitching/tingling sensation. A sigmoid function was fitted to the subject responses to find the threshold at a specific frequency and duration, and the whole procedure was repeated at all relevant frequencies and pulse durations. Results: The magnetostimulation limits decreased with increasing pulse duration (T{sub pulse}). For T{sub pulse} < 18 ms, the thresholds were significantly higher than at the longest pulse durations (p < 0.01, paired Wilcoxon signed-rank test). The normalized magnetostimulation threshold (B{sub Norm}) vs duration curve at all three frequencies agreed almost identically, indicating that the observed effect is independent of the operating frequency. At the shortest pulse duration (T{sub pulse} ≈ 2 ms), the thresholds were approximately 24% higher than at the asymptotes. The thresholds decreased to within 4% of their asymptotic values for T{sub pulse} > 20 ms. These trends were well characterized (R{sup 2} = 0.78) by a stretched exponential function given by B{sub Norm}=1+αe{sup −(T{sub p}{sub u}{sub l}{sub s}{sub e}/β){sup γ}}, where the fitted parameters were α = 0.44, β = 4.32, and γ = 0.60. Conclusions: This work shows for the first time that the magnetostimulation thresholds decrease with increasing pulse duration, and that this effect is independent of the operating frequency. Normalized threshold vs duration trends are almost identical for a 20-fold range of frequencies: the thresholds are significantly higher at short pulse durations and settle to within 4% of their asymptotic values for durations longer than 20 ms. These results emphasize the importance of matching the human-subject experiments to the imaging conditions of a particular setup. Knowing the dependence of the safety limits to all contributing factors is critical for increasing the time-efficiency of imaging systems that utilize time-varying magnetic fields.« less
NASA Astrophysics Data System (ADS)
Jain, Richa; Luthra, Vandna; Gokhale, Shubha
2018-06-01
Fe3-xRExO4 (RE = Er, Dy and Gd) nanoparticles with x varying from 0 to 0.1 were synthesized using co-precipitation method. The synthesized nanoparticles were characterized using X-ray diffraction (XRD), transmission electron microscopy (TEM), vibrating sample magnetometer (VSM) and UV-Vis spectroscopy techniques. TEM images reveal round shaped particles of ∼8-14 nm diameter in case of undoped magnetite (Fe3O4) nanoparticles whereas there is evolution of rod like structures by the doping of RE ions with aspect ratio in the range of 6-16. The room temperature saturation magnetization (Ms) values show gradual increase with doping till a critical doping level which is found to depend on the ionic radius of dopant ion (x = 0.01 for Er, 0.03 for Dy and 0.04 for Gd). There is a variation in the maximum value of saturation magnetization which is directly proportional to the number of unpaired 4f electrons in the dopant element. Low temperature magnetization study, carried out at 5 K and 120 K reveal an increase in the value of Ms as well as coercivity. The direct bandgaps calculated from UV-Visible data are found to decrease with increasing number of unpaired electrons in the dopant ions.
Tandonnet, Christophe; Garry, Michael I; Summers, Jeffery J
2011-04-01
Selecting the adequate alternative in choice situations may involve an inhibition process. Here we assessed response implementation during the reaction time of a between-hand choice task with single- or paired-pulse (3 or 15 ms interstimulus intervals [ISIs]) transcranial magnetic stimulation of the motor cortex. The amplitude of the single-pulse motor evoked potential (MEP) initially increased for both hands. At around 130 ms, the single-pulse MEP kept increasing for the responding hand and decreased for the nonresponding hand. The paired-pulse MEP revealed a similar pattern for both ISIs with no effect on short intracortical inhibition and intracortical facilitation measures. The results suggest that the incorrect response implementation was selectively suppressed before execution of the correct response, preventing errors in choice context. The results favor models assuming that decision making involves an inhibition process. Copyright © 2010 Society for Psychophysiological Research.
Flux amplification and sustainment of ST plasmas by multi-pulsed coaxial helicity injection on HIST
NASA Astrophysics Data System (ADS)
Higashi, T.; Ishihara, M.; Kikuchi, Y.; Fukumoto, N.; Nagata, M.
2010-11-01
The Helicity Injected Spherical Torus (HIST) device has been developed towards high-current start up and sustainment by Multi-pulsed Coaxial Helicity Injection (M-CHI) method. Multiple pulses operation of the coaxial plasma gun can build the magnetic field of STs and spheromak plasmas in a stepwise manner. So far, successive gun pulses on SSPX at LLNL were demonstrated to maintain the magnetic field of spheromak in a quasi-steady state against resistive decay [1]. The resistive 3D-MHD numerical simulation [2] for STs reproduced the current amplification by the M-CHI method and confirmed that stochastic magnetic field was reduced during the decay phase. By double pulsed operation on HIST, the plasma current was effectively amplified against the resistive decay. The life time increases up to 10 ms which is longer than that in the single CHI case (4 ms). The edge poloidal fields last between 0.5 ms and 6 ms like a repetitive manner. During the second driven phase, the toroidal ion flow is driven in the same direction as the plasma current as well as in the initial driven phase. At the meeting, we will discuss a current amplification mechanism based on the merging process with the plasmoid injected secondly from the gun. [1] B. Hudson et al., Phys. Plasmas Vol.15, 056112 (2008). [2] Y. Kagei et al., J. Plasma Fusion Res. Vol.79, 217 (2003).
Bio inspired Magnet-polymer (Magpol) actuators
NASA Astrophysics Data System (ADS)
Ahmed, Anansa S.; Ramanujan, R. V.
2014-03-01
Magnet filler-polymer matrix composites (Magpol) are an emerging class of morphing materials. Magpol composites have an interesting ability to undergo large strains in response to an external magnetic field. The potential to develop Magpol as large strain actuators is due to the ability to incorporate large particle loading into the composite and also due to the increased interaction area at the interface of the nanoparticles and the composite. Mn-Zn ferrite fillers with different saturation magnetizations (Ms) were synthesized. Magpol composites consisting of magnetic ferrite filler particles in an Poly ethylene vinyl acetate (EVA) matrix were prepared. The deformation characteristics of the actuator were determined. The morphing ability of the Magpol composite was studied under different magnetic fields and also with different filler loadings. All films exhibited large strain under the applied magnetic field. The maximum strain of the composite showed an exponential dependence on the Ms. The work output of Magpol was also calculated using the work loop method. Work densities of upto 1 kJ/m3 were obtained which can be compared to polypyrrole actuators, but with almost double the typical strain. Applications of Magpol can include artificial muscles, drug delivery, adaptive optics and self healing structures. Advantages of Magpol include remote contactless actuation, high actuation strain and strain rate and quick response.
NASA Astrophysics Data System (ADS)
Ali, MA; Uddin, MM; Khan, MNI; Chowdhury, FUZ; Hoque, SM; Liba, SI
2017-06-01
A series of Ni0.6-x/2Zn0.4-x/2Sn x Fe2O4 (x = 0.0, 0.05, 0.1, 0.15, 0.2, and 0.3) (NZSFO) ferrite composities have been synthesized from nano powders using a standard solid state reaction technique. The spinel cubic structure of the investigated samples has been confirmed by x-ray diffraction (XRD). The magnetic properties such as saturation magnetization ({M}{{s}}), remanent magnetization ({M}{{r}}), coercive field ({H}{{c}}), and Bohr magneton (μ) are calculated from the hysteresis loops. The value of {M}{{s}} is found to decrease with increasing Sn content in the samples. This change is successfully explained by the variation of A-B interaction strength due to Sn substitution in different sites. The compositional stability and quality of the prepared ferrite composites have also been endorsed by the fairly constant initial permeability ({μ }^{\\prime }) over a wide range of frequency. The decreasing trend of {μ }^{\\prime } with increasing Sn content has been observed. Curie temperature {T}{{C}} has been found to increase with the increase in Sn content. A wide spread frequency utility zone indicates that the NZSFO can be considered as a good candidate for use in broadband pulse transformers and wide band read-write heads for video recording. The composition of x = 0.05 shows unusual results and the possible reason is also mentioned with the established formalism.
MRI in the assessment and monitoring of multiple sclerosis: an update on best practice
Kaunzner, Ulrike W.; Gauthier, Susan A.
2017-01-01
Magnetic resonance imaging (MRI) has developed into the most important tool for the diagnosis and monitoring of multiple sclerosis (MS). Its high sensitivity for the evaluation of inflammatory and neurodegenerative processes in the brain and spinal cord has made it the most commonly used technique for the evaluation of patients with MS. Moreover, MRI has become a powerful tool for treatment monitoring, safety assessment as well as for the prognostication of disease progression. Clinically, the use of MRI has increased in the past couple decades as a result of improved technology and increased availability that now extends well beyond academic centers. Consequently, there are numerous studies supporting the role of MRI in the management of patients with MS. The aim of this review is to summarize the latest insights into the utility of MRI in MS. PMID:28607577
Effect of word familiarity on visually evoked magnetic fields.
Harada, N; Iwaki, S; Nakagawa, S; Yamaguchi, M; Tonoike, M
2004-11-30
This study investigated the effect of word familiarity of visual stimuli on the word recognizing function of the human brain. Word familiarity is an index of the relative ease of word perception, and is characterized by facilitation and accuracy on word recognition. We studied the effect of word familiarity, using "Hiragana" (phonetic characters in Japanese orthography) characters as visual stimuli, on the elicitation of visually evoked magnetic fields with a word-naming task. The words were selected from a database of lexical properties of Japanese. The four "Hiragana" characters used were grouped and presented in 4 classes of degree of familiarity. The three components were observed in averaged waveforms of the root mean square (RMS) value on latencies at about 100 ms, 150 ms and 220 ms. The RMS value of the 220 ms component showed a significant positive correlation (F=(3/36); 5.501; p=0.035) with the value of familiarity. ECDs of the 220 ms component were observed in the intraparietal sulcus (IPS). Increments in the RMS value of the 220 ms component, which might reflect ideographical word recognition, retrieving "as a whole" were enhanced with increments of the value of familiarity. The interaction of characters, which increased with the value of familiarity, might function "as a large symbol"; and enhance a "pop-out" function with an escaping character inhibiting other characters and enhancing the segmentation of the character (as a figure) from the ground.
Magnetic resonance techniques for investigation of multiple sclerosis
NASA Astrophysics Data System (ADS)
MacKay, Alex; Laule, Cornelia; Li, David K. B.; Meyers, Sandra M.; Russell-Schulz, Bretta; Vavasour, Irene M.
2014-11-01
Multiple sclerosis (MS) is a common neurological disease which can cause loss of vision and balance, muscle weakness, impaired speech, fatigue, cognitive dysfunction and even paralysis. The key pathological processes in MS are inflammation, edema, myelin loss, axonal loss and gliosis. Unfortunately, the cause of MS is still not understood and there is currently no cure. Magnetic resonance imaging (MRI) is an important clinical and research tool for MS. 'Conventional' MRI images of MS brain reveal bright lesions, or plaques, which demark regions of severe tissue damage. Conventional MRI has been extremely valuable for the diagnosis and management of people who have MS and also for the assessment of therapies designed to reduce inflammation and promote repair. While conventional MRI is clearly valuable, it lack pathological specificity and, in some cases, sensitivity to non-lesional pathology. Advanced MR techniques have been developed to provide information that is more sensitive and specific than what is available with clinical scanning. Diffusion tensor imaging and magnetization transfer provide a general but non-specific measure of the pathological state of brain tissue. MR spectroscopy provides concentrations of brain metabolites which can be related to specific pathologies. Myelin water imaging was designed to assess brain myelination and has proved useful for measuring myelin loss in MS. To combat MS, it is crucial that the pharmaceutical industry finds therapies which can reverse the neurodegenerative processes which occur in the disease. The challenge for magnetic resonance researchers is to design imaging techniques which can provide detailed pathological information relating to the mechanisms of MS therapies. This paper briefly describes the pathologies of MS and demonstrates how MS-associated pathologies can be followed using both conventional and advanced MR imaging protocols.
Performance and Thermal Characterization of the NASA-300MS 20 kW Hall Effect Thruster
NASA Technical Reports Server (NTRS)
Kamhawi, Hani; Huang, Wensheng; Haag, Thomas; Shastry, Rohit; Soulas, George; Smith, Timothy; Mikellides, Ioannis; Hofer, Richard
2013-01-01
NASA's Space Technology Mission Directorate is sponsoring the development of a high fidelity 15 kW-class long-life high performance Hall thruster for candidate NASA technology demonstration missions. An essential element of the development process is demonstration that incorporation of magnetic shielding on a 20 kW-class Hall thruster will yield significant improvements in the throughput capability of the thruster without any significant reduction in thruster performance. As such, NASA Glenn Research Center and the Jet Propulsion Laboratory collaborated on modifying the NASA-300M 20 kW Hall thruster to improve its propellant throughput capability. JPL and NASA Glenn researchers performed plasma numerical simulations with JPL's Hall2De and a commercially available magnetic modeling code that indicated significant enhancement in the throughput capability of the NASA-300M can be attained by modifying the thruster's magnetic circuit. This led to modifying the NASA-300M magnetic topology to a magnetically shielded topology. This paper presents performance evaluation results of the two NASA-300M magnetically shielded thruster configurations, designated 300MS and 300MS-2. The 300MS and 300MS-2 were operated at power levels between 2.5 and 20 kW at discharge voltages between 200 and 700 V. Discharge channel deposition from back-sputtered facility wall flux, and plasma potential and electron temperature measurements made on the inner and outer discharge channel surfaces confirmed that magnetic shielding was achieved. Peak total thrust efficiency of 64% and total specific impulse of 3,050 sec were demonstrated with the 300MS-2 at 20 kW. Thermal characterization results indicate that the boron nitride discharge chamber walls temperatures are approximately 100 C lower for the 300MS when compared to the NASA- 300M at the same thruster operating discharge power.
NASA Astrophysics Data System (ADS)
Saravanan, P.; Vinod, V. T. P.; Černík, Miroslav; Selvapriya, A.; Chakravarty, Dibyendu; Kamat, S. V.
2015-01-01
The potential of spark plasma sintering (SPS) in combination with rapid thermal annealing (RTA) for the processing of Mn-Al nanostructured magnets is explored in this study. Ferromagnetic α-Mn alloy powders were processed by high-energy ball milling using Mn (56 at%) and Al (44 at%) as constituent metal elements. The alloying action between Mn and Al due to intensive milling was studied by X-ray diffraction and field-emission scanning electron microscope; while the phase transformation kinetics was investigated using differential scanning calorimetry. The evolution of ferromagnetic properties in the as-milled powders was studied by superconducting quantum interference device (SQUID). Among the Mn-Al alloy powders collected at various milling intervals, the 25 h milled Mn-Al powders showed a good combination of coercivity, Hc (11.3 kA/m) and saturation magnetization, Ms (5.0 A/m2/kg); accordingly, these powders were chosen for SPS. The SPS experiments were conducted at different temperatures: 773, 873 and 973 K and its effect on the density, phase composition and magnetic properties of the Mn-Al bulk samples were investigated. Upon increasing the SPS temperature from 773 to 973 K, the bulk density was found to increase from 3.6 to 4.0 g/cm3. The occurrence of equilibrium β-phase with significant amount of γ2-phase was obvious at all the SPS temperatures; however, crystallization of some amount of τ-phase was evident at 973 K. Irrespective of the SPS temperatures, all the samples demonstrated soft magnetic behavior with Hc and Ms values similar to those obtained for the 25 h milled powders. The magnetic properties of the SPSed samples were significantly improved upon subjecting them to RTA at 1100 K. Through the RTA process, Hc values of 75, 174 and 194 kA/m and Ms values of 19, 21 and 28 A/m2/kg were achieved for the samples SPSed at 773, 873 and 973 K, respectively. The possible reasons for the observed improvement in the magnetic properties of the SPSed samples due to RTA in correlation with their phase composition and microstructure were analyzed and discussed.
Prediction of Ba, Mn and Zn for tropical soils using iron oxides and magnetic susceptibility
NASA Astrophysics Data System (ADS)
Marques Júnior, José; Arantes Camargo, Livia; Reynaldo Ferracciú Alleoni, Luís; Tadeu Pereira, Gener; De Bortoli Teixeira, Daniel; Santos Rabelo de Souza Bahia, Angelica
2017-04-01
Agricultural activity is an important source of potentially toxic elements (PTEs) in soil worldwide but particularly in heavily farmed areas. Spatial distribution characterization of PTE contents in farming areas is crucial to assess further environmental impacts caused by soil contamination. Designing prediction models become quite useful to characterize the spatial variability of continuous variables, as it allows prediction of soil attributes that might be difficult to attain in a large number of samples through conventional methods. This study aimed to evaluate, in three geomorphic surfaces of Oxisols, the capacity for predicting PTEs (Ba, Mn, Zn) and their spatial variability using iron oxides and magnetic susceptibility (MS). Soil samples were collected from three geomorphic surfaces and analyzed for chemical, physical, mineralogical properties, as well as magnetic susceptibility (MS). PTE prediction models were calibrated by multiple linear regression (MLR). MLR calibration accuracy was evaluated using the coefficient of determination (R2). PTE spatial distribution maps were built using the values calculated by the calibrated models that reached the best accuracy by means of geostatistics. The high correlations between the attributes clay, MS, hematite (Hm), iron oxides extracted by sodium dithionite-citrate-bicarbonate (Fed), and iron oxides extracted using acid ammonium oxalate (Feo) with the elements Ba, Mn, and Zn enabled them to be selected as predictors for PTEs. Stepwise multiple linear regression showed that MS and Fed were the best PTE predictors individually, as they promoted no significant increase in R2 when two or more attributes were considered together. The MS-calibrated models for Ba, Mn, and Zn prediction exhibited R2 values of 0.88, 0.66, and 0.55, respectively. These are promising results since MS is a fast, cheap, and non-destructive tool, allowing the prediction of a large number of samples, which in turn enables detailed mapping of large areas. MS predicted values enabled the characterization and the understanding of spatial variability of the studied PTEs.
Enhancement of iron content in spinach plants stimulated by magnetic nano particles
DOE Office of Scientific and Technical Information (OSTI.GOV)
Yulianto, Agus; Astuti, Budi; Amalia, Saptaria Rosa
In our previous study, the iron content in spinach plants could be detected by magnetic susceptibility values. In the present work, magnetic nano particles were found from the iron sand. The magnetic nano particles are synthesis by using co-precipitation process and sol-gel technique. The stimulation of magnetic nano particles in the plant has been done by the provision of magnetic nano particles in growing media. After certain time, plant samples was characterized using susceptibility-meter MS2B and atomic absorption spectroscopy to measure the magnetic susceptibility and the amount of iron content that absorbed of the plant, respectively. The iron content inmore » the spinach plants was increased when the magnetic nano particles was injected in the growing media.« less
Patellar cartilage lesions: comparison of magnetic resonance imaging and T2 relaxation-time mapping.
Hannila, I; Nieminen, M T; Rauvala, E; Tervonen, O; Ojala, R
2007-05-01
To evaluate the detection and the size of focal patellar cartilage lesions in T2 mapping as compared to standard clinical magnetic resonance imaging (MRI) at 1.5T. Fifty-five consecutive clinical patients referred to knee MRI were imaged both with a standard knee MRI protocol (proton-density-weighted sagittal and axial series, T2-weighted sagittal and coronal series, and T1-weighted coronal series) and with an axial multislice multi-echo spin-echo measurement to determine the T2 relaxation time of the patellar cartilage. MR images and T2 maps of patellar cartilage were evaluated for focal lesions. The lesions were evaluated for lesion width (mm), lesion depth (1/3, 2/3, or 3/3 of cartilage thickness), and T2 value (20-40 ms, 40-60 ms, or 60-80 ms) based on visual evaluation. Altogether, 36 focal patellar cartilage lesions were detected from 20 human subjects (11 male, nine female, mean age 40+/-15 years). Twenty-eight lesions were detected both on MRI and T2 maps, while eight lesions were only visible on T2 maps. Cartilage lesions were significantly wider (P = 0.001) and thicker (P<0.001) on T2 maps as compared to standard knee MRI. Most lesions 27 had moderately (T2 40-60 ms) increased T2 values, while two lesions had slightly (T2 20-40 ms) and seven lesions remarkably (T2 60-80 ms) increased T2 relaxation times. T2 mapping of articular cartilage is feasible in the clinical setting and may reveal early cartilage lesions not visible with standard clinical MRI.
Modulation of motor cortex excitability by paired peripheral and transcranial magnetic stimulation.
Kumru, Hatice; Albu, Sergiu; Rothwell, John; Leon, Daniel; Flores, Cecilia; Opisso, Eloy; Tormos, Josep Maria; Valls-Sole, Josep
2017-10-01
Repetitive application of peripheral electrical stimuli paired with transcranial magnetic stimulation (rTMS) of M1 cortex at low frequency, known as paired associative stimulation (PAS), is an effective method to induce motor cortex plasticity in humans. Here we investigated the effects of repetitive peripheral magnetic stimulation (rPMS) combined with low frequency rTMS ('magnetic-PAS') on intracortical and corticospinal excitability and whether those changes were widespread or circumscribed to the cortical area controlling the stimulated muscle. Eleven healthy subjects underwent three 10min stimulation sessions: 10HzrPMS alone, applied in trains of 5 stimuli every 10s (60 trains) on the extensor carpi radialis (ECR) muscle; rTMS alone at an intensity 120% of ECR threshold, applied over motor cortex of ECR and at a frequency of 0.1Hz (60 stimuli) and magnetic PAS, i.e., paired rPMS and rTMS. We recorded motor evoked potentials (MEPs) from ECR and first dorsal interosseous (FDI) muscles. We measured resting motor threshold, motor evoked potentials (MEP) amplitude at 120% of RMT, short intracortical inhibition (SICI) at interstimulus interval (ISI) of 2ms and intracortical facilitation (ICF) at an ISI of 15ms before and immediately after each intervention. Magnetic-PAS , but not rTMS or rPMS applied separately, increased MEP amplitude and reduced short intracortical inhibition in ECR but not in FDI muscle. Magnetic-PAS can increase corticospinal excitability and reduce intracortical inhibition. The effects may be specific for the area of cortical representation of the stimulated muscle. Application of magnetic-PAS might be relevant for motor rehabilitation. Copyright © 2017 International Federation of Clinical Neurophysiology. All rights reserved.
NASA Astrophysics Data System (ADS)
Mahmoudi, Soulmaz; Gholizadeh, Ahmad
2018-06-01
In this work, Y3-xSrxZrxFe5O12 (0.0 ≤ x ≤ 0.7) were synthesized by citrate precursor method at 1050 °C. The structural and magnetic properties of Y3-xSrxFe5-xZrxO12 were studied by using the X-ray diffraction technique, scanning electron microscopy, transmission electron microscopy, the Fourier transform infrared spectroscopy and vibrating sample magnetometer. XRD analysis using X'Pert package show a pure garnet phase with cubic structure (space group Ia-3d) and the impurity phase SrZrO3 is observed when the range of x value is exceeded from 0.6. Rietveld refinement using Fullprof program shows the lattice volume expansion with increasing the degree of Sr/Zr substitution. The crystallite sizes remain constant in the range of x = 0.0 - 0.5 and then increase. The different morphology observed in SEM micrographs of the samples can be related to different values of the microstrain in the samples. The hysteresis loops of the samples reveal a superparamagnetic behaviour. Also, the drop in coercivity with increasing of the substitution is mainly originated from a reduction in the magneto-elastic anisotropy energy. The values of the saturation magnetization (MS) indicate a non-monotonically variant with increasing the Sr/Zr substitution and reach a maximum 26.14 emu/g for the sample x = 0.1 and a minimum 17.64 emu/g for x = 0.0 and x = 0.2. The variation of MS, in these samples results from a superposition of three factors; reduction of Fe3+ in a-site, change in angle FeT-O-FeO, and magnetic core size.
Phase Transitions and Magnetocaloric Properties in MnCo 1-x Zr x Ge Compounds
Aryal, Anil; Quetz, Abdiel; Pandey, Sudip; ...
2017-06-13
Tmore » he structural, magnetic, and magnetocaloric properties of MnC o 1 - x Z r x Ge ( 0.01 ≤ x ≤ 0.04 ) have been studied through X-ray diffraction, differential scanning calorimetry, and magnetization measurements. Results indicate that the partial substitution of Zr for Co in MnC o 1 - x Z r x Ge decreases the martensitic transition temperature ( M ). For x = 0.02, M was found to coincide with the ferromagnetic transition temperature ( C ) resulting in a first-order magnetostructural transition (MS). A further increase in zirconium concentration ( x = 0.04) showed a single transition at C . he MS from the paramagnetic to ferromagnetic state results in magnetic entropy changes ( - Δ S M ) of 7.2 J/kgK for Δ H = 5 at 274 K for x = 0.02. he corresponding value of the relative cooling power (RCP) was found to be 266 J/kg for Δ H = 5 . hus, the observed large value of MCE and RCP makes this system a promising material for magnetic cooling applications.« less
Phase Transitions and Magnetocaloric Properties in MnCo 1-x Zr x Ge Compounds
DOE Office of Scientific and Technical Information (OSTI.GOV)
Aryal, Anil; Quetz, Abdiel; Pandey, Sudip
Tmore » he structural, magnetic, and magnetocaloric properties of MnC o 1 - x Z r x Ge ( 0.01 ≤ x ≤ 0.04 ) have been studied through X-ray diffraction, differential scanning calorimetry, and magnetization measurements. Results indicate that the partial substitution of Zr for Co in MnC o 1 - x Z r x Ge decreases the martensitic transition temperature ( M ). For x = 0.02, M was found to coincide with the ferromagnetic transition temperature ( C ) resulting in a first-order magnetostructural transition (MS). A further increase in zirconium concentration ( x = 0.04) showed a single transition at C . he MS from the paramagnetic to ferromagnetic state results in magnetic entropy changes ( - Δ S M ) of 7.2 J/kgK for Δ H = 5 at 274 K for x = 0.02. he corresponding value of the relative cooling power (RCP) was found to be 266 J/kg for Δ H = 5 . hus, the observed large value of MCE and RCP makes this system a promising material for magnetic cooling applications.« less
Magnetic field effects of photocarrier generation in bulk heterojunctions at low temperature.
Tajima, H; Nishioka, Y; Sato, S; Suzuki, T; Kimata, M
2016-11-14
We report an experimental investigation of the magnetic field effect (MFE) in polymer bulk heterojunction devices at temperatures below 10 K using photocarrier extraction by linearly increasing voltages. The examined devices were composed of an active layer of poly(3-hexylthiophene) and [6,6]-phenyl-C 61 -butyric acid methyl ester. In the experiments, the delay time (t d ) dependence of the MFE was investigated in detail. For t d < 80 μs, a positive MFE was observed in the field region B < 0.1 T and a negative MFE was observed for B > 0.2 T. For t d > 8 ms, only a positive MFE proportional to B 2 was observed. For the photocurrent pulse detected immediately after light irradiation, the MFE was negligibly small. In a high magnetic field of 15 T, a significant MFE exceeding 80% was observed at 1.8 K for t d = 800 ms. We discuss the results based on a model of triplet-singlet (or singlet-triplet) conversion in the magnetic field and estimate the exchange integral for the charge-transfer exciton in this photovoltaic cell.
Thaler, Christian; Faizy, Tobias; Sedlacik, Jan; Holst, Brigitte; Stellmann, Jan-Patrick; Young, Kim Lea; Heesen, Christoph; Fiehler, Jens; Siemonsen, Susanne
2015-01-01
Magnetic Resonance Imaging (MRI) is an established tool in diagnosing and evaluating disease activity in Multiple Sclerosis (MS). While clinical-radiological correlations are limited in general, hypointense T1 lesions (also known as Black Holes (BH)) have shown some promising results. The definition of BHs is very heterogeneous and depends on subjective visual evaluation. We aimed to improve clinical-radiological correlations by defining BHs using T1 relaxation time (T1-RT) thresholds to achieve best possible correlation between BH lesion volume and clinical disability. 40 patients with mainly relapsing-remitting MS underwent MRI including 3-dimensional fluid attenuated inversion recovery (FLAIR), magnetization-prepared rapid gradient echo (MPRAGE) before and after Gadolinium (GD) injection and double inversion-contrast magnetization-prepared rapid gradient echo (MP2RAGE) sequences. BHs (BHvis) were marked by two raters on native T1-weighted (T1w)-MPRAGE, contrast-enhancing lesions (CE lesions) on T1w-MPRAGE after GD and FLAIR lesions (total-FLAIR lesions) were detected separately. BHvis and total-FLAIR lesion maps were registered to MP2RAGE images, and the mean T1-RT were calculated for all lesion ROIs. Mean T1 values of the cortex (CTX) were calculated for each patient. Subsequently, Spearman rank correlations between clinical scores (Expanded Disability Status Scale and Multiple Sclerosis Functional Composite) and lesion volume were determined for different T1-RT thresholds. Significant differences in T1-RT were obtained between all different lesion types with highest T1 values in visually marked BHs (BHvis: 1453.3±213.4 ms, total-FLAIR lesions: 1394.33±187.38 ms, CTX: 1305.6±35.8 ms; p<0.05). Significant correlations between BHvis/total-FLAIR lesion volume and clinical disability were obtained for a wide range of T1-RT thresholds. The highest correlation for BHvis and total-FLAIR lesion masks were found at T1-RT>1500 ms (Expanded Disability Status Scale vs. lesion volume: rBHvis = 0.442 and rtotal-FLAIR = 0.497, p<0.05; Multiple Sclerosis Functional Composite vs. lesion volume: rBHvis = -0.53 and rtotal-FLAIR = -0.627, p<0.05). Clinical-radiological correlations in MS patients are increased by application of T1-RT thresholds. With the short acquisition time of the MP2RAGE sequences, quantitative T1 maps could be easily established in clinical studies.
NASA Astrophysics Data System (ADS)
Anjana, V.; John, Sara; Prakash, Pooja; Nair, Amritha M.; Nair, Aravind R.; Sambhudevan, Sreedha; Shankar, Balakrishnan
2018-02-01
Nickel ferrite nanoparticles with copper atoms as dopant have been prepared using co-precipitation method with general formula Ni1-xCuxFe2O4 (x=0.2, 0.4, 0.6, 0.8 and 1) and are sintered at quite ambient temperature. Structural and magnetic properties were examined using Fourier Transform Infrared Spectroscopy (FTIR), X-ray Diffraction method (XRD) and Vibrating Sample Magnetometer (VSM) to study the influence of copper doping in nickel ferrite magnetic nanoparticles. X-ray studies proves that the particles are possessing single phase spinel structure with an average particle size calculated using Debye Scherer formula. Magnetic measurements reveal that saturation magnetization value (Ms) decreases while magnetic coercivity (Hc) increases upon doping.
Photospheric Magnetic Flux Transport - Supergranules Rule
NASA Technical Reports Server (NTRS)
Hathaway, David H.; Rightmire-Upton, Lisa
2012-01-01
Observations of the transport of magnetic flux in the Sun's photosphere show that active region magnetic flux is carried far from its origin by a combination of flows. These flows have previously been identified and modeled as separate axisymmetric processes: differential rotation, meridional flow, and supergranule diffusion. Experiments with a surface convective flow model reveal that the true nature of this transport is advection by the non-axisymmetric cellular flows themselves - supergranules. Magnetic elements are transported to the boundaries of the cells and then follow the evolving boundaries. The convective flows in supergranules have peak velocities near 500 m/s. These flows completely overpower the superimposed 20 m/s meridional flow and 100 m/s differential rotation. The magnetic elements remain pinned at the supergranule boundaries. Experiments with and without the superimposed axisymmetric photospheric flows show that the axisymmetric transport of magnetic flux is controlled by the advection of the cellular pattern by underlying flows representative of deeper layers. The magnetic elements follow the differential rotation and meridional flow associated with the convection cells themselves -- supergranules rule!
Zasońska, Beata A; Hlídková, Helena; Petrovský, Eduard; Myronovskij, Severyn; Nehrych, Tetyana; Negrych, Nazar; Shorobura, Mariya; Antonyuk, Volodymyr; Stoika, Rostyslav; Kit, Yuriy; Horák, Daniel
2018-04-23
Monodisperse nonmagnetic macroporous poly(glycidyl methacrylate) (PGMA) microspheres were synthesized by multistep swelling polymerization of glycidyl methacrylate, ethylene dimethacrylate and 2-[(methoxycarbonyl)methoxy]ethyl methacrylate (MCMEMA). This was followed (a) by ammonolysis to modify the microspheres with amino groups, and (b) by incorporation of iron oxide (γ-Fe 2 O 3 ) into the pores to render the particles magnetic. The resulting porous and magnetic microspheres were characterized by scanning and transmission electron microscopy (SEM and TEM), atomic absorption and Fourier transform infrared spectroscopy (AAS and FTIR), elemental analysis, vibrating magnetometry, mercury porosimetry and Brunauer-Emmett-Teller adsorption/desorption isotherms. The microspheres are meso- and macroporous, typically 5 μm in diameter, contain 0.9 mM · g -1 of amino groups and 14 wt.% of iron according to elemental analysis and AAS, respectively. The particles were conjugated to p46/Myo1C protein, a potential biomarker of autoimmune diseases, to isolate specific autoantibodies in the blood of patients suffering from multiple sclerosis (MS). The p46/Myo1C loaded microspheres are shown to enable the preconcentration of minute quantities of specific immunoglobulins prior to their quantification via SDS-PAGE. The immunoglobulin M (IgM) with affinity to Myo1C was detected in MS patients. Graphical abstract Monodisperse magnetic poly(glycidyl methacrylate) microspheres were synthesized, conjugated with 46 kDa form of unconventional Myo1C protein (p46/Myo1C) via carbodiimide (DIC) chemistry, and specific autoantibodies isolated from blood of multiple sclerosis (MS) patients; immunoglobulin M (IgM) level increased in MS patients.
Increased tissue damage and lesion volumes in African Americans with multiple sclerosis.
Weinstock-Guttman, B; Ramanathan, M; Hashmi, K; Abdelrahman, N; Hojnacki, D; Dwyer, M G; Hussein, S; Bergsland, N; Munschauer, F E; Zivadinov, R
2010-02-16
African American (AA) patients with multiple sclerosis (MS) have more rapid disease progression and poorer responses to disease-modifying therapies than white American (WA) patients with MS. To investigate brain MRI characteristics in AA compared to WA in a cohort of consecutive patients with MS. We studied 567 patients with MS (age: 45.1 +/- SD 9.8 years, disease duration: 13.4 +/- 8.6 years), comprised of 488 WA and 79 AA. All patients obtained clinical and quantitative MRI evaluation. The majority of patients, 96% of AA and 94% of WA, were on disease-modifying therapies. The MRI measures included T1-, T2-, and gadolinium contrast-enhancing (CE) lesion volumes (LV) and CE number, global and tissue-specific brain atrophy, and magnetization transfer ratio (MTR) in lesions and normal-appearing gray matter (NAGM) and white matter (NAWM). The associations between race and clinical and MRI measurements were assessed in regression analysis. The MTR values in lesions and in NAGM and NAWM were significantly lower in AA compared to WA. The AA group had 31% greater T2-LV and 101% greater T1-LV compared to WA. The MS Severity Score for AA (mean +/- SD = 4.3 +/- 2.9) was greater than for WA (3.8 +/- 2.5), despite a shorter disease duration in AA, indicating more aggressive clinical disease. African American patients showed increased tissue damage, as measured by magnetization transfer ratio, and presented higher lesion volumes compared to white Americans. The greater tissue damage and faster lesion volume accumulation may explain the rapid clinical progression in African American patients.
Response characteristic of high-speed on/off valve with double voltage driving circuit
NASA Astrophysics Data System (ADS)
Li, P. X.; Su, M.; Zhang, D. B.
2017-07-01
High-speed on/off valve, an important part of turbocharging system, its quick response has a direct impact on the turbocharger pressure cycle. The methods of improving the response characteristic of high speed on/off valve include increasing the magnetic force of armature and the voltage, decreasing the mass and current of coil. The less coil number of turns, the solenoid force is smaller. The special armature structure and the magnetic material will raise cost. In this paper a new scheme of double voltage driving circuit is investigated, in which the original driving circuit of high-speed on/off valve is replaced by double voltage driving circuit. The detailed theoretical analysis and simulations were carried out on the double voltage driving circuit, it showed that the switching time and delay time of the valve respectively are 3.3ms, 5.3ms, 1.9ms and 1.8ms. When it is driven by the double voltage driving circuit, the switching time and delay time of this valve are reduced, optimizing its response characteristic. By the comparison related factors (such as duty cycle or working frequency) about influences on response characteristic, the superior of double voltage driving circuit has been further confirmed.
Effect of graphite content on magnetic and mechanical properties of TiC-TiN-Mo-Ni cermets
NASA Astrophysics Data System (ADS)
Zhang, Man; Yang, Qingqing; Xiong, Weihao; Huang, Bin; Ruan, Linji; Mao, Qiao; Li, Shengtao
2018-04-01
TiC-10TiN-6Mo-xGr-yNi (mol%, Gr represents graphite, x = 0, 2, 4, 6, 8, and y = 15, 30) cermets were prepared by powder metallurgy method, in order to inverstigate the effect of Gr content on magnetic and mechanical properties of TiC-TiN-Mo-Ni cermets. Room-temperature (RT) saturation magnetization (Ms) and remanence (Mr) of cermets increased with increasing x. This was mainly attributed to that the total content of non-ferromagnetic carbonitride-forming elements Ti and Mo in Ni-based binder phase decreased with increasing x. At the same x, cermets for y = 15 had lower RT Ms and Mr than those for y = 30. Cermets containing more than 2 mol% Gr became ferromagnetic at RT. Bending strength of cermets first increased and then decreased with increasing x. It reached the maximum at x = 2, mainly due to high total content of solutes Ti and Mo in Ni-based binder phase, and moderate thickness of outer rim of Ti(C,N) ceramic grains. Hardness of cermets was not significantly affected by x, mainly due to the combined action of the decrease of the total content of Ti and Mo in binder phase and the increase of the volume fraction of ceramic grains. At the same x, cermets for y = 15 had lower bending strength and higher hardness than those for y = 30.
Structural and magnetic characterization of Ti doped cobalt ferrite (CoFe2O4)
NASA Astrophysics Data System (ADS)
Pal, Jaswinder; Kumar, Sunil; Kaur, Randeep; Agrawal, P.; Singh, Mandeep; Singh, Anupinder
2018-05-01
Synthesis of Co1-xTixFe2O4 solid solutions for 0.1≤x≤0.4 using the solid-state-reaction rate has been done. The prepared samples were characterized by using XRD (X-ray diffraction) and SEM (Scanning Electron Microscopy). Magnetic studies have been done using Vibrating Sample Magnetometer (VSM). XRD confirmed that Cobalt Ferrite spinel cubic structure in all prepared samples. The lattice parameter `a' increases with increase in the concentration of Ti. SEM micrograph shows good grain growth in all samples. Magnetic Study reveals that the M-H curves of all the prepared samples taken at room temperature are very well saturated. The maximum value of remnant magnetization (Mr ˜13.9 emu/g) and saturation magnetization (Ms ˜74.4 emu/g) has been observed for x =0.2 sample. Coercivity does not show any regular variation with increase in the molar concentration of Ti in CoFe2O4 at A-site.
Thompson, P D; Day, B L; Crockard, H A; Calder, I; Murray, N M; Rothwell, J C; Marsden, C D
1991-01-01
Activity in descending motor pathways after scalp electrical and magnetic brain stimulation of the motor cortex was recorded from the exposed cervico-medullary junction in six patients having trans-oral surgery of the upper cervical spine. Recordings during deep anaesthesia without muscle paralysis revealed an initial negative potential (D wave) at about 2 ms with electrical stimulation in five of the six patients. This was followed by a muscle potential which obscured any later waveforms. Magnetic stimulation produced clear potentials in only one patient. The earliest wave to magnetic stimulation during deep anaesthesia was 1-2 ms later than the earliest potential to electrical stimulation. Following lightening of the anaesthetic and the administration of muscle relaxants a series of later negative potentials (I waves) were more clearly seen to both electrical and magnetic stimulation. More I waves were recorded to magnetic stimulation during light anaesthesia than during deep anaesthesia. Increasing the intensity of electrical stimulation also produced an extra late I wave. At the highest intensity of magnetic stimulation the latency of the earliest potential was comparable to the D wave to electrical stimulation. The intervals between these various D and I waves corresponded to those previously described for the timing of single motor unit discharge after cortical stimulation. PMID:1654395
Magnetics and Power System Upgrades for the Pegasus-U Experiment
NASA Astrophysics Data System (ADS)
Preston, R. C.; Bongard, M. W.; Fonck, R. J.; Lewicki, B. T.
2014-10-01
To support the missions of developing local helicity injection startup and exploiting advanced tokamak physics studies at near unity aspect ratio, the proposed Pegasus-U will include expanded magnetic systems and associated power supplies. A new centerstack increases the toroidal field seven times to 1 T and the volt-seconds by a factor of six while maintaining operation at an aspect ratio of 1.2. The poloidal field magnet system is expanded to support improved shape control and robust double or single null divertor operation at the full plasma current of 0.3 MA. An integrated digital control system based on Field Programmable Gate Arrays (FPGAs) provides active feedback control of all magnet currents. Implementation of the FPGAs is achieved with modular noise reducing electronics. The digital feedback controllers replace the existing analog systems and switch multiplexing technology. This will reduce noise sensitivity and allow the operational Ohmic power supply voltage to increase from 2100 V to its maximum capacity of 2400 V. The feedback controller replacement also allows frequency control for ``freewheeling''--stopping the switching for a short interval and allowing the current to coast. The FPGAs assist in optimizing pulse length by having programmable switching events to minimize energy losses. They also allow for more efficient switching topologies that provide improved stored energy utilization, and support increasing the pulse length from 25 ms to 50-100 ms. Work supported by US DOE Grant DE-FG02-96ER54375.
Influence of peripheral magnetic stimulation of soleus muscle on H and M waves.
Matsuda, Tadamitsu; Kurayama, Taichi; Tagami, Miki; Fujino, Yuji; Manji, Atsushi; Kusumoto, Yasuaki; Amimoto, Kazu
2018-05-01
[Purpose] This study evaluated the effects of repetitive peripheral magnetic stimulation of the soleus muscle on spinal cord and peripheral motor nerve excitability. [Subjects and Methods] Twelve healthy adults (mean age 22 years) who provided written informed consent were administered repetitive peripheral magnetic stimulation for 10 min. Pre-and post-stimulation latencies and amplitudes of H- and M-waves of the soleus muscle were measured using electromyography and compared using paired t-tests. [Results] Pre- and post-stimulation latencies (28.3 ± 3.3 vs. 29.1 ± 1.3 ms, respectively) and amplitudes (35.8 ± 1.3 vs. 35.8 ± 1.1 mV, respectively) of H-waves were similar. Pre-stimulation latencies of M-waves were significantly higher than post-stimulation latencies (6.1 ± 2.2 vs. 5.0 ± 0.9 ms, respectively), although pre- and post-stimulation amplitudes were similar (12.2 ± 1.4 vs. 12.2 ± 1.3 mV, respectively). Motor neuron excitability, based on the excitability of motor nerves and peripheral nerve action, was increased by M-waves following magnetic stimulation. [Conclusion] The lack of effect of magnetic stimulation on the amplitude and latency of the H-reflex suggests that magnetic stimulation did not activate sensory nerve synapses of α motor neurons in the spinal cord. However, because motor nerves were stimulated together with sensory nerves, the increased H-wave amplitude may have reflected changes in peripheral rather than in α motor nerves.
Afshari, Daryoush; Moradian, Nasrin; Khalili, Majid; Razazian, Nazanin; Bostani, Arash; Hoseini, Jamal; Moradian, Mohamad; Ghiasian, Masoud
2016-10-01
Evidence is mounting that magnet therapy could alleviate the symptoms of multiple sclerosis (MS). This study was performed to test the effects of the pulsing magnetic fields on the paresthesia in MS patients. This study has been conducted as a randomized, double-blind, parallel-group clinical trial during the April 2012 to October 2013. The subjects were selected among patients referred to MS clinic of Imam Reza Hospital; affiliated to Kermanshah University of Medical Sciences, Iran. Sixty three patients with MS were included in the study and randomly were divided into two groups, 35 patients were exposed to a magnetic pulsing field of 4mT intensity and 15-Hz frequency sinusoidal wave for 20min per session 2 times per week over a period of 2 months involving 16 sessions and 28 patients was exposed to a magnetically inactive field (placebo) for 20min per session 2 times per week over a period of 2 months involving 16 sessions. The severity of paresthesia was measured by the numerical rating scale (NRS) at 30, 60days. The study primary end point was NRS change between baseline and 60days. The secondary outcome was NRS change between baseline and 30days. Patients exposing to magnetic field showed significant paresthesia improvement compared with the group of patients exposing to placebo. According to our results pulsed magnetic therapy could alleviate paresthesia in MS patients .But trials with more patients and longer duration are mandatory to describe long-term effects. Copyright © 2016 Elsevier B.V. All rights reserved.
Udupa, Kaviraja; Bahl, Nina; Ni, Zhen; Gunraj, Carolyn; Mazzella, Filomena; Moro, Elena; Hodaie, Mojgan; Lozano, Andres M; Lang, Anthony E; Chen, Robert
2016-01-13
Noninvasive brain stimulation studies have shown abnormal motor cortical plasticity in Parkinson's disease (PD). These studies used peripheral nerve stimulation paired with transcranial magnetic stimulation (TMS) to primary motor cortex (M1) at specific intervals to induce plasticity. Induction of cortical plasticity through stimulation of the basal ganglia (BG)-M1 connections has not been studied. In the present study, we used a novel technique of plasticity induction by repeated pairing of deep-brain stimulation (DBS) of the BG with M1 stimulation using TMS. We hypothesize that repeated pairing of subthalamic nucleus (STN)-DBS and M1-TMS at specific time intervals will lead to plasticity in the M1. Ten PD human patients with STN-DBS were studied in the on-medication state with DBS set to 3 Hz. The interstimulus intervals (ISIs) between STN-DBS and TMS that produced cortical facilitation were determined individually for each patient. Three plasticity induction conditions with repeated pairings (180 times) at specific ISIs (∼ 3 and ∼ 23 ms) that produced cortical facilitation and a control ISI of 167 ms were tested in random order. Repeated pairing of STN-DBS and M1-TMS at short (∼ 3 ms) and medium (∼ 23 ms) latencies increased M1 excitability that lasted for at least 45 min, whereas the control condition (fixed ISI of 167 ms) had no effect. There were no specific changes in motor thresholds, intracortical circuits, or recruitment curves. Our results indicate that paired-associative cortical plasticity can be induced by repeated STN and M1 stimulation at specific intervals. These results show that STN-DBS can modulate cortical plasticity. We introduced a new experimental paradigm to test the hypothesis that pairing subthalamic nucleus deep-brain stimulation (STN-DBS) with motor cortical transcranial magnetic stimulation (M1-TMS) at specific times can induce cortical plasticity in patients with Parkinson's disease (PD). We found that repeated pairing of STN-DBS with TMS at short (∼ 3 ms) and medium (∼ 23 ms) intervals increased cortical excitability that lasted for up to 45 min, whereas the control condition (fixed latency of 167 ms) had no effects on cortical excitability. This is the first demonstration of associative plasticity in the STN-M1 circuits in PD patients using this novel technique. The potential therapeutic effects of combining DBS and noninvasive cortical stimulation should be investigated further. Copyright © 2016 the authors 0270-6474/16/360397-09$15.00/0.
Nyadong, Leonard; Harris, Glenn A.; Balayssac, Stéphane; Galhena, Asiri S.; Malet-Martino, Myriam; Martino, Robert; Parry, R. Mitchell; Wang, May Dongmei; Fernández, Facundo M.; Gilard, Véronique
2016-01-01
During the past decade, there has been a marked increase in the number of reported cases involving counterfeit medicines in developing and developed countries. Particularly, artesunate-based antimalarial drugs have been targeted, because of their high demand and cost. Counterfeit antimalarials can cause death and can contribute to the growing problem of drug resistance, particularly in southeast Asia. In this study, the complementarity of two-dimensional diffusion-ordered 1H nuclear magnetic resonance spectroscopy (2D DOSY 1H NMR) with direct analysis in real-time mass spectrometry (DART MS) and desorption electrospray ionization mass spectrometry (DESI MS) was assessed for pharmaceutical forensic purposes. Fourteen different artesunate tablets, representative of what can be purchased from informal sources in southeast Asia, were investigated with these techniques. The expected active pharmaceutical ingredient was detected in only five formulations via both nuclear magnetic resonance (NMR) and mass spectrometry (MS) methods. Common organic excipients such as sucrose, lactose, stearate, dextrin, and starch were also detected. The graphical representation of DOSY 1H NMR results proved very useful for establishing similarities among groups of samples, enabling counterfeit drug “chemotyping”. In addition to bulk- and surface-average analyses, spatially resolved information on the surface composition of counterfeit and genuine antimalarial formulations was obtained using DESI MS that was performed in the imaging mode, which enabled one to visualize the homogeneity of both genuine and counterfeit drug samples. Overall, this study suggests that 2D DOSY 1H NMR, combined with ambient MS, comprises a powerful suite of instrumental analysis methodologies for the integral characterization of counterfeit antimalarials. PMID:19453162
Nyadong, Leonard; Harris, Glenn A; Balayssac, Stéphane; Galhena, Asiri S; Malet-Martino, Myriam; Martino, Robert; Parry, R Mitchell; Wang, May Dongmei; Fernández, Facundo M; Gilard, Véronique
2009-06-15
During the past decade, there has been a marked increase in the number of reported cases involving counterfeit medicines in developing and developed countries. Particularly, artesunate-based antimalarial drugs have been targeted, because of their high demand and cost. Counterfeit antimalarials can cause death and can contribute to the growing problem of drug resistance, particularly in southeast Asia. In this study, the complementarity of two-dimensional diffusion-ordered (1)H nuclear magnetic resonance spectroscopy (2D DOSY (1)H NMR) with direct analysis in real-time mass spectrometry (DART MS) and desorption electrospray ionization mass spectrometry (DESI MS) was assessed for pharmaceutical forensic purposes. Fourteen different artesunate tablets, representative of what can be purchased from informal sources in southeast Asia, were investigated with these techniques. The expected active pharmaceutical ingredient was detected in only five formulations via both nuclear magnetic resonance (NMR) and mass spectrometry (MS) methods. Common organic excipients such as sucrose, lactose, stearate, dextrin, and starch were also detected. The graphical representation of DOSY (1)H NMR results proved very useful for establishing similarities among groups of samples, enabling counterfeit drug "chemotyping". In addition to bulk- and surface-average analyses, spatially resolved information on the surface composition of counterfeit and genuine antimalarial formulations was obtained using DESI MS that was performed in the imaging mode, which enabled one to visualize the homogeneity of both genuine and counterfeit drug samples. Overall, this study suggests that 2D DOSY (1)H NMR, combined with ambient MS, comprises a powerful suite of instrumental analysis methodologies for the integral characterization of counterfeit antimalarials.
Tuning static and dynamic properties of FeGa/NiFe heterostructures
NASA Astrophysics Data System (ADS)
Rementer, Colin R.; Fitzell, Kevin; Xu, Qiang; Nordeen, Paul; Carman, Gregory P.; Wang, Yuanxun E.; Chang, Jane P.
2017-06-01
In this work, the frequency-dependent magnetic properties of sputtered Galfenol/Permalloy (Fe85Ga15/Ni81Fe19 or FeGa/NiFe) magnetic multilayers were examined to tailor their magnetic softness, loss at microwave frequencies, permeability, and magnetoelasticity, leveraging the magnetic softness and low loss of NiFe and the high saturation magnetostriction (λs) and magnetization (MS) of FeGa. The total volume of each material and their ratio were kept constant, and the number of alternating layers was increased (with decreasing individual layer thickness) to assess the role of increasing interfaces in these magnetic heterostructures. A systematic change was observed as the number of bilayers or interfaces increases: a seven-bilayer structure results in an 88% reduction in coercivity and a 55% reduction in ferromagnetic resonance linewidth at the X-band compared to a single phase FeGa film, while maintaining a high relative permeability of 700. The magnetostriction was slightly reduced by the addition of NiFe but was still maintained at up to 67% that of single phase FeGa. The tunability of these magnetic heterostructures makes them excellent candidates for RF magnetic applications requiring strong magnetoelastic coupling and low loss.
NASA Astrophysics Data System (ADS)
Belmeguenai, M.; Gabor, M. S.; Zighem, F.; Roussigné, Y.; Faurie, D.; Tiusan, C.
2016-09-01
Co2FeAl (CFA) thin films, of various thicknesses (3 nm≤t ≤50 nm ), have been grown by sputtering on (001) MgO single-crystal substrates and annealed at different temperatures (RT≤Ta≤600 ∘C , where RT is the room temperature). The influence of the CFA thickness (t ), as well as ex situ annealing temperature (Ta), on the magnetic and structural properties has been investigated by x-ray diffraction (XRD), vibrating sample magnetometry, and broadband microstrip ferromagnetic resonance (MS-FMR). The XRD revealed an epitaxial growth of the films with the cubic [001] CFA axis normal to the substrate plane and that the chemical order varies from the B 2 phase to the A 2 phase when decreasing t or Ta. The deduced lattice parameters showed an in-plane tetragonal distortion and in-plane and out-plane strains that increase with Ta and 1 /t . For all Ta values, the variation of the effective magnetization, deduced from the fit of MS-FMR measurements, shows two different regimes separated by a critical thickness, which is Ta dependent. It decreases (increases) linearly with the inverse thickness (1 /t ) in the first (second) regime due to the contribution of the magnetoelastic anisotropy to surface (to volume) anisotropy. The observed behavior has been analyzed through a model allowing for the separation of the magnetocrystalline, magnetoelastic, and Néel-type interface anisotropy constants to the surface and the volume anisotropies. Similar behavior has been observed for the effective fourfold anisotropy field which governs the in-plane anisotropy present in all the samples. Finally, the MS-FMR data also allow one to conclude that the gyromagnetic factor remains constant and that the exchange stiffness constant increases with Ta.
Neuroinflammatory component of gray matter pathology in multiple sclerosis.
Herranz, Elena; Giannì, Costanza; Louapre, Céline; Treaba, Constantina A; Govindarajan, Sindhuja T; Ouellette, Russell; Loggia, Marco L; Sloane, Jacob A; Madigan, Nancy; Izquierdo-Garcia, David; Ward, Noreen; Mangeat, Gabriel; Granberg, Tobias; Klawiter, Eric C; Catana, Ciprian; Hooker, Jacob M; Taylor, Norman; Ionete, Carolina; Kinkel, Revere P; Mainero, Caterina
2016-11-01
In multiple sclerosis (MS), using simultaneous magnetic resonance-positron emission tomography (MR-PET) imaging with 11 C-PBR28, we quantified expression of the 18kDa translocator protein (TSPO), a marker of activated microglia/macrophages, in cortex, cortical lesions, deep gray matter (GM), white matter (WM) lesions, and normal-appearing WM (NAWM) to investigate the in vivo pathological and clinical relevance of neuroinflammation. Fifteen secondary-progressive MS (SPMS) patients, 12 relapsing-remitting MS (RRMS) patients, and 14 matched healthy controls underwent 11 C-PBR28 MR-PET. MS subjects underwent 7T T2*-weighted imaging for cortical lesion segmentation, and neurological and cognitive evaluation. 11 C-PBR28 binding was measured using normalized 60- to 90-minute standardized uptake values and volume of distribution ratios. Relative to controls, MS subjects exhibited abnormally high 11 C-PBR28 binding across the brain, the greatest increases being in cortex and cortical lesions, thalamus, hippocampus, and NAWM. MS WM lesions showed relatively modest TSPO increases. With the exception of cortical lesions, where TSPO expression was similar, 11 C-PBR28 uptake across the brain was greater in SPMS than in RRMS. In MS, increased 11 C-PBR28 binding in cortex, deep GM, and NAWM correlated with neurological disability and impaired cognitive performance; cortical thinning correlated with increased thalamic TSPO levels. In MS, neuroinflammation is present in the cortex, cortical lesions, deep GM, and NAWM, is closely linked to poor clinical outcome, and is at least partly linked to neurodegeneration. Distinct inflammatory-mediated factors may underlie accumulation of cortical and WM lesions. Quantification of TSPO levels in MS could prove to be a sensitive tool for evaluating in vivo the inflammatory component of GM pathology, particularly in cortical lesions. Ann Neurol 2016;80:776-790. © 2016 American Neurological Association.
Magnetic Susceptibility as a Proxy for Investigating Microbial Mediated Iron Reduction
We investigated magnetic susceptibility (MS) variations in hydrocarbon contaminated sediments. Our objective was to determine if MS can be used as an intrinsic bioremediation indicator due to the activity of iron-reducing bacteria. A contaminated and an uncontaminated core were r...
NASA Astrophysics Data System (ADS)
Rey, D.; Mohamed, K. J.; Andrade, A.; Rubio, B.; Bernabeu, A. M.
2017-12-01
The wide use of magnetic proxies to study pollution, sedimentological processes, and environmental and paleoclimatic changes is currently limited by the lack of transference functions that closely correlate with the unmeasurable variables. Among them, magnetic susceptibility (MS) is the oldest and most popular, but have yet to live up to its expectations. This paper explores and quantifies how MS values of surficial sediments in transitional environments depends on grain size and on what can be said about the spatial distribution of hydrodynamic forces and the potential modulation of MS by sediment and organic matter provenances. The concentration of (oxyhydr)oxides in sands (d50 > 63 microns) is primarily controlled by their degree of dilution in the diamagnetic framework, which is larger for coarser grainsizes. In contrast, the concentration of (oxyhydr)oxides in muddy sediments is controlled by their dissolution rate during very early diagenesis, which is controlled by their content in organic matter (TOC), inversely dependent of grainsize. The balance between both components results in the study area in sands of d50 = 68 microns displaying the maximum MS values. The influence of organic matter on the dissolution of magnetite in surficial sediments can be quantified using a simple kinetic model. The model reveals the existence of a negative exponential relationship between magnetic susceptibility and grain size, that depends on the TOC of the fine-grained fraction. The model accurately predicts that a TOC increase of 0.35% results in a 50% reduction in the concentration of magnetite in the sediments of the Ría the Muros. We have also encountered this relationship not universal in this form, as its quantification is strongly modulated by coarse sediment mineralogy, TOC lability and by other factors such as wave climate, depth, and sediment oxygenation. Better understanding and quantification of the role that TOC, hydrodynamics, and changes in the geochemical environment have on the surface and downcore evolution of magnetic properties is useful to correctly interpret magnetic properties as proxies for pollutants, sedimentological processes, and environmental and paleoclimatic changes.
Correlations Between Structural and Magnetic Properties of Co2 FeSi Heusler-Alloy Thin Films
NASA Astrophysics Data System (ADS)
Zhu, Weihua; Wu, Di; Zhao, Bingcheng; Zhu, Zhendong; Yang, Xiaodi; Zhang, Zongzhi; Jin, Q. Y.
2017-09-01
The structural and magnetic properties are the most important parameters for practical applications of Co-based Heusler alloys. The correlations between the crystallization degree, chemical order, magnetic coercivity, saturation magnetization (MS ), and in-plane magnetic anisotropies are systematically investigated for Co2FeSi (CFS) films fabricated at different temperatures (TS ). XRD shows that the CFS layer changes progressively from a disordered crystal structure into a chemically disordered A 2 structure and further into a chemically ordered B 2 and even L 21 structures when increasing TS up to 480 °C . Meanwhile, the static angular remanence magnetization curves show a clear transition of magnetic anisotropy from twofold to fourfold symmetry, due to the competition effect between the uniaxial anisotropy field HU and biaxial anisotropy field HB . The HU value is found to be weakly dependent on TS , while HB shows a continuous enhancement at TS>300 °C , implying that the enhancement of the L 21 ordering degree would not weaken the biaxial anisotropy. The varying trend of HB is similar to MS , which can be respectively attributed to the improved crystal structure and chemical order. The anisotropic fields and their variation behaviors determined by a vibrating sample magnetometer are highly consistent with the results by a time-resolved magneto-optical Kerr effect study. Our findings provide a better understanding of the structural ordering and magnetic anisotropy, which will be helpful for designing advanced spintronic devices.
Microparticules magnetiques therapeutiques pour la chimio-embolisation ciblee du foie
NASA Astrophysics Data System (ADS)
Pouponneau, Pierre
The proposed project introduces a therapeutic vector for the liver tumor treatment based on a new magnetic targeting strategy. The hypothesis of this thesis is that it is possible to design a therapeutic vector compatible with the constraints of liver chemoembolization and MRN in the hepatic artery to target the right/left lobe of the liver. This vector, referred to as therapeutic magnetic microcarriers (TMMC) is loaded with an antitumor drug and magnetic nanoparticles. A design study, based on a mathematical modeling of microparticle steering and a literature review on the chemoembolization, was done to optimize TMMC properties (diameter, Ms, nanoparticle choice and loading). Iron-cobalt (FeCo) nanoparticles were synthesized and annealed under inert conditions to improve their magnetic properties. These ferromagnetic nanoparticles possessed a mean diameter of 200 nm, measured by transmission electronic microscopy, and an Ms of 205 emu g-1, determined with a vibrating sample magnetometer. These nanoparticles, by their high Ms, allowed reducing by half the magnetic material loading in TMMC compared with the encapsulation of iron oxide nanoparticles. The nanoparticles coated with 10-nm graphite shell were protected from oxidation and thus they maintained their excellent magnetic properties. The design study was experimentally confirmed by the encapsulation of FeCo nanoparticles into poly(lactic-co-glycolic acid (PLGA) biodegradable microparticles. The latter were steered in vitro in a phantom mimicking the hepatic artery and its right/left bifurcation. The steering efficiency was determined by steering video analysis and the iron and cobalt ion concentrations were assayed by atomic absorption spectrometry in each bifurcation. FeCo nanoparticles were then co-encapsulated with doxorubicin (DOX) into PLGA microparticles. DOX is an antitumor drug widely used for HCC treatments. TMMC possessed a mean diameter of 52 mum, an Ms of 72 emu g-1 and they were loaded with 37% (w/w) of nanoparticles and 3% (w/w) of DOX. In vitro, after 3 days of elution in phosphate buffered saline solution, 54% of the DOX encapsulated remained in the TMMC. The elution was characterized by a fast release phase during one hour and then a slow kinetics. The steering was evaluated in vitro in a phantom mimicking the hepatic artery under physiological and interventional radiology conditions (injection by catheter, variation of distance between the catheter and the bifurcation from 30 to 20 mm, magnetic gradient from 200 to 400 mT m -1, flow velocity from 7.5 to 12 cm s-1). Steering efficiency was defined as the reduction of the TMMC (or drug) dose in the untargeted area in the presence of magnetic steering versus the negative control (no steering). The steering efficiency increased when the magnetic gradient increased. The efficiency decreased when the flow velocity increased and the catheter was closer to the bifurcation. The efficiency decreased with microparticles with lower steering properties (diameter of 30 mum and Ms of 49 emu g-1). This result confirmed that the TMMC properties were specific to the vascular network being targeted. In the optimal conditions, the steering efficiency reached 70%. The steering of TMMC was measured in vivo. An interventional radiology protocol compatible with MRN was developed to place the catheters, to reduce the hepatic artery blood velocity during the steering and to determine the MRI sequence parameters. TMMC induced signal loss on T2*-weighted magnetic resonance images because of their high Ms which allowed their easy localization in the tissues. The embolization of the hepatic artery branches by TMMC was confirmed by histological analysis. The sustained release of DOX was verified by measuring its plasmatic concentration. TMMC distribution in the tissues was determined by the histological analysis and DOX and cobalt concentration measurements. A significant difference in the TMMC distribution in the liver lobes between the group with MRN and the control group was obtained. The MRN allowed reducing the microparticle concentration in the untargeted area. In the optimal conditions, the steering efficiency reached 50%. The parameters influencing the steering efficiency in vitro were confirmed during in vivo tests. (Abstract shortened by UMI.)
NASA Astrophysics Data System (ADS)
Xu, Feng; Chen, Xin; Ma, Yungui; Phuoc, N. N.; Zhang, Xiaoyu; Ong, C. K.
2008-10-01
In this work, the high-frequency magnetic permeability spectra of as-sputtered FeCoSiN films with various Si concentrations were investigated. The soft magnetic properties with an induced in-plane uniaxial anisotropy can only be obtained within some composition ranges because of the formation of different granular microstructures. The permeability spectra measured without any external fields (He) were well fitted based on the phenomenological Landau-Lifshitz-Gilbert equation. Results show that with the increase in Si concentration, the saturated magnetization 4πMs, the resonance frequency fr, the permeability μ, and the qualify factor Q values decrease, while the damping coefficient α and resonant frequency linewidth Δf increase. The increase in Gilbert damping coefficient α or G is ascribed to the increase in mosaicity or magnetic ripples with higher volume proportion of Si-rich matrix. The investigations on Δf-He relations indicate the extrinsic damping contribution from the two-magnon scattering in FeCoSiN, which is suggested to be due to the change in the granular microstructures compared with FeCoN.
Effect of pressure on the metamagnetic transition of DyB 6 single crystal
NASA Astrophysics Data System (ADS)
Sakai, T.; Oomi, G.; Uwatoko, Y.; Kunii, S.
2007-03-01
The effects of pressure on the magnetization ( M) and the magnetostriction (MS) for DyB 6 single crystal have been measured at 4.2 K. It is found that the M loops are insensitive to pressure, whereas the large MS with magnitude of 0.5% at 5 T at ambient pressure is rapidly suppressed by applying pressure. The metamagnetic transition field HM in the M curve increases slightly by applying pressure with the rate of increase, ∂ ln HM/∂ P, of 0.03 GPa -1, which is almost the same value as that for TN, 0.04 GPa -1.
NASA Astrophysics Data System (ADS)
Jing, Panpan; Liu, Mengting; Pu, Yongping; Cui, Yongfei; Wang, Zhuo; Wang, Jianbo; Liu, Qingfang
2016-11-01
Iron-nickel (Fe-Ni) alloy nanoribbons were reported for the first time by deoxidizing NiFe2O4 nanoribbons, which were synthesized through a handy route of electrospinning followed by air-annealing at 450 °C, in hydrogen (H2) at different temperatures. It was demonstrated that the phase configurations, microstructures and magnetic properties of the as-deoxidized samples closely depended upon the deoxidization temperature. The spinel NiFe2O4 ferrite of the precursor nanoribbons were firstly deoxidized into the body-centered cubic (bcc) Fe-Ni alloy and then transformed into the face-centered cubic (fcc) Fe-Ni alloy of the deoxidized samples with the temperature increasing. When the deoxidization temperature was in the range of 300 ~ 500 °C, although each sample possessed its respective morphology feature, all of them completely reserved the ribbon-like structures. When it was further increased to 600 °C, the nanoribbons were evolved completely into the fcc Fe-Ni alloy nanochains. Additionally, all samples exhibited typical ferromagnetism. The saturation magnetization (Ms) firstly increased, then decreased, and finally increased with increasing the deoxidization temperature, while the coercivity (Hc) decreased monotonously firstly and then basically stayed unchanged. The largest Ms (~145.7 emu·g-1) and the moderate Hc (~132 Oe) were obtained for the Fe-Ni alloy nanoribbons with a mixed configuration of bcc and fcc phases.
NASA Astrophysics Data System (ADS)
Grison, Hana; Petrovsky, Eduard; Kapicka, Ales; Hanzlikova, Hana
2017-05-01
In studies of the magnetic properties of soils, the frequency-dependent magnetic susceptibility percentage (χFD%) is often used for the identification of ultrafine magnetically superparamagnetic/stable single-domain (SP/SSD) particles. This parameter is commonly used as an indicator for increased pedogenesis. In strongly magnetic soils, the SP/SSD magnetic signal (mostly bio-pedogenic) may be masked by lithological signals; making pedogenesis hard to detect. In this study, we compare results for the detection of ultrafine SP/SSD magnetic particles in andic soils using two instruments: a Bartington MS2B dual-frequency meter and an AGICO Kappabridge MFK1-FA. In particular, the study focuses on the effect of pedogenesis by investigating the relationship between specific soil magnetic and chemical properties (soil organic carbon and pHH2O). The values of χFD% obtained with the MS2B varied from 2.4 to 5.9 per cent, and mass-specific magnetic susceptibility (χLF) from 283 to 1688 × 10-8 m3 kg-1, while values of χFD% and χLF obtained with the MFK1-FA varied from 2.7 to 8.2 per cent and from 299 to 1859 × 10-8 m3 kg-1, respectively. Our results suggest that the detection of the SP/SSD magnetic fraction can be accomplished by comparing relative trends of χFD% along the soil profile. Moreover, the discrimination between bio-pedogenic and lithogenic magnetic contributions in the SP/SSD fraction is possible by comparing the χFD% and χLF data determined in the fine earth (<2 mm) and the coarse fraction (4-10 mm) samples down the soil profile.
Diagnosing Autism Spectrum Disorder through Brain Functional Magnetic Resonance Imaging
2016-03-01
Diagnosing Autism Spectrum Disorder through Brain Functional Magnetic Resonance Imaging THESIS MARCH 2016 Kyle A. Palko, Second Lieutenant, USAF AFIT...declared a work of the U.S. Government and is not subject to copyright protection in the United States. AFIT-ENC-MS-16-M-123 DIAGNOSING AUTISM SPECTRUM...PUBLIC RELEASE; DISTRIBUTION UNLIMITED. AFIT-ENC-MS-16-M-123 DIAGNOSING AUTISM SPECTRUM DISORDER THROUGH BRAIN FUNCTIONAL MAGNETIC RESONANCE IMAGING Kyle
Zangemeister, W H; Nagel, M
2001-01-01
We investigated coordinated saccadic eye and head movements following predictive horizontal visual targets at +/- 30 degrees by applying transcranial magnetic stimulation (TMS) over the cerebellum before the start of the gaze movement in 10 young subjects. We found three effects of TMS on eye-head movements: 1. Saccadic latency effect. When stimulation took place shortly before movements commenced (75-25 ms before), significantly shorter latencies were found between predictive target presentation and initiation of saccades. Eye latencies were significantly decreased by 45 ms on average, but head latencies were not. 2. Gaze amplitude effect. Without TMS, for the 60 degrees target amplitudes, head movements usually preceded eye movements, as expected (predictive gaze type 3). With TMS 5-75 ms before the gaze movement, the number of eye movements preceding head movements by 20-50 ms was significantly increased (p < 0.001) and the delay between eye and head movements was reversed (p < 0.001), i.e. we found eye-predictive gaze type 1. 3. Saccadic peak velocity effect. For TMS 5-25 s before the start of head movement, mean peak velocity of synkinetic eye saccades increased by 20-30% up to 600 degrees/s, compared to 350-400 degrees/s without TMS. We conclude that transient functional cerebellar deficits exerted by means of TMS can change the central synkinesis of eye-head coordination, including the preprogramming of the saccadic pulse and step of a coordinated gaze movement.
Understanding the role of iron in the magnetism of Fe doped ZnO nanoparticles.
Beltrán, J J; Barrero, C A; Punnoose, A
2015-06-21
The actual role of transition metals like iron in the room temperature ferromagnetism (RTFM) of Fe doped ZnO nanoparticles is still an unsolved problem. While some studies concluded that the Fe ions participate in the magnetic interaction, others in contrast do not believe Fe to play a direct role in the magnetic exchange interaction. To contribute to the understanding of this issue, we have carefully investigated the structural, optical, vibrational and magnetic properties of sol-gel synthesized Zn1-xFexO (0 < x < 0.10) nanoparticles. No Fe(2+) was detected in any sample. We found that high spin Fe(3+) ions are substitutionally incorporated at the Zn(2+) in the tetrahedral-core sites and in pseudo-octahedral surface sites in ZnO. Superficial OH(-) was observed in all samples. For x ≤ 0.03, an increment in Fe doping concentration decreased a and c lattice parameters, average Zn-O bond length, average crystallite size and band gap; while it increased the degree of distortion and quadrupole splitting. Undoped ZnO nanoparticles exhibited very weak RTFM with a saturation magnetization (Ms) of ∼0.47 memu g(-1) and this value increased to ∼2.1 memu g(-1) for Zn0.99Fe0.01O. Very interestingly, the Ms for Zn0.99Fe0.01O and Zn0.97Fe0.03O increased by a factor of about ∼2.3 by increasing annealing for 1 h to 3 h. For x ≥ 0.05, ferrimagnetic disordered spinel ZnFe2O4 was formed and this phase was found to become more ordered with increasing annealing time. Fe does not contribute directly to the RTFM, but its presence promoted the formation of additional single charged oxygen vacancies, zinc vacancies, and more oxygen-ended polar terminations at the nanoparticle surface. These defects, which are mainly superficial, altered the electronic structure and are considered as the main sources of the observed ferromagnetism.
Magnetic properties of Co2Fe(Ga1-xSix) alloys
NASA Astrophysics Data System (ADS)
Deka, Bhargab; Chakraborty, Dibyashree; Srinivasan, Ananthakrishnan
2014-09-01
Magnetic and crystallographic properties of bulk Co2Fe(Ga1-xSix) alloys with 0≤x≤1 are reported in this work. The alloys with x=0.75 and 1.00 exhibit L21 structure whereas the alloys with x=0, 0.25 and 0.50 crystallized in the disordered A2 phase. Unit cell volume of this series of alloys decreased from 189.1 to 178.5 Å3 as x was increased from 0 to 1.00. All alloy compositions exhibit ferromagnetic behavior with a high Curie temperature (TC) which showed a systematic variation with x (1089 K, 1075 K, 1059 K, 1019 K and 1015 K for x=0, 0.25, 0.5, 0.75 and 1.00, respectively). The saturation magnetization moment Ms for the alloys with x=0, 0.25 and 0.50 are 5.05μB, 5.23μB, 5.49μB, respectively, in accordance with the Slater-Pauling rule, but alloys with x=0.75 and 1.00 deviated from this rule. The effective moment per magnetic atom (pc) of the alloys was estimated from the inverse DC magnetic susceptibility data above TC. A comparison of Ms with pc reveals the half-metallic character of the alloys.
Jayaraman, T. V.; Meka, V. M.; Jiang, X.; ...
2018-01-09
Here we investigated the ambient temperature structural properties (thickness, width, microstructure, and lattice parameter), and the ambient and high temperature (up to 900 K) direct current (DC) magnetic properties—saturation magnetization (M S) and intrinsic coercivity (H CI)—of rapidly-solidified (melt-spun) Fe-x wt.% Si (x = 3, 5, & 8) alloys. The wheel surface speeds selected for the study were 30 m/s and 40 m/s. The ribbons produced at the lower wheel surface speed (30 m/s) were continuous having relatively uniform edges compared to the ribbons produced at the higher wheel surface speed. The thickness and the width of the melt-spun ribbonsmore » ranged between ~15 and 60 μm and 500–800 μm, respectively. The x-ray diffraction spectra of the melt-spun ribbons indicated the presence of disordered α-phase, irrespective of the composition, and the wheel surface speed. The lattice parameter decreased gradually as a function of increasing silicon content from ~0.2862 nm (Fe-3 wt.% Si) to ~0.2847 nm (Fe-8 wt.% Si). The wheel surface speed showed an insignificant effect on M S while increased silicon content resulted in a decreasing trend in M S. Elevated temperature evaluation of the magnetization (M-T curves at ~7.96 kA/m) in the case of Fe-3 & 5 wt.% Si alloy ribbons was distinctly different from that of the Fe-8 wt.% Si alloy ribbons. The curves of the as-prepared Fe-3 wt.% Si and Fe-5 wt.% Si alloy ribbons were irreversible while that of Fe-8 wt.% Si was reversible. The M S for any of the combinations of wheel surface speed and composition decreased monotonically with the increase in temperature (from 300 to 900 K). While H CI increased with the increase in temperature for all the wheel surface speed and composition combination, its nature of increase is distinct for Fe-8 wt.% Si alloy ribbons compared to Fe-3 & 5 wt.% Si alloys ribbons. Finally, it appears that rapidly-solidified Fe-3 wt.% Si and Fe-5 wt.% Si alloys ribbons are primarily comprised of the α phase (disordered phase) while the Fe-8 wt.% Si alloy ribbons are comprised primarily of disordered phase along with minor constituents of an ordered phase.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Jayaraman, T. V.; Meka, V. M.; Jiang, X.
Here we investigated the ambient temperature structural properties (thickness, width, microstructure, and lattice parameter), and the ambient and high temperature (up to 900 K) direct current (DC) magnetic properties—saturation magnetization (M S) and intrinsic coercivity (H CI)—of rapidly-solidified (melt-spun) Fe-x wt.% Si (x = 3, 5, & 8) alloys. The wheel surface speeds selected for the study were 30 m/s and 40 m/s. The ribbons produced at the lower wheel surface speed (30 m/s) were continuous having relatively uniform edges compared to the ribbons produced at the higher wheel surface speed. The thickness and the width of the melt-spun ribbonsmore » ranged between ~15 and 60 μm and 500–800 μm, respectively. The x-ray diffraction spectra of the melt-spun ribbons indicated the presence of disordered α-phase, irrespective of the composition, and the wheel surface speed. The lattice parameter decreased gradually as a function of increasing silicon content from ~0.2862 nm (Fe-3 wt.% Si) to ~0.2847 nm (Fe-8 wt.% Si). The wheel surface speed showed an insignificant effect on M S while increased silicon content resulted in a decreasing trend in M S. Elevated temperature evaluation of the magnetization (M-T curves at ~7.96 kA/m) in the case of Fe-3 & 5 wt.% Si alloy ribbons was distinctly different from that of the Fe-8 wt.% Si alloy ribbons. The curves of the as-prepared Fe-3 wt.% Si and Fe-5 wt.% Si alloy ribbons were irreversible while that of Fe-8 wt.% Si was reversible. The M S for any of the combinations of wheel surface speed and composition decreased monotonically with the increase in temperature (from 300 to 900 K). While H CI increased with the increase in temperature for all the wheel surface speed and composition combination, its nature of increase is distinct for Fe-8 wt.% Si alloy ribbons compared to Fe-3 & 5 wt.% Si alloys ribbons. Finally, it appears that rapidly-solidified Fe-3 wt.% Si and Fe-5 wt.% Si alloys ribbons are primarily comprised of the α phase (disordered phase) while the Fe-8 wt.% Si alloy ribbons are comprised primarily of disordered phase along with minor constituents of an ordered phase.« less
Changes in Magnetic Mineralogy Through a Depth Sequence of Hydrocarbon Contaminated Sediments
NASA Astrophysics Data System (ADS)
Ameen, N. N.; Klüglein, N.; Appel, E.; Petrovsky, E.; Kappler, A.
2013-12-01
Sediments, soils and groundwater can act as a natural storage for many types of pollution. This study aims to investigate ferro(i)magnetic phase formation and transformation in the presence of organic contaminants (hydrocarbons) and its relation to bacterial activity, in particular in the zone of fluctuating water levels. The work extends previous studies conducted at the same site. The study area is a former military air base at Hradčany, Czech Republic (50°37'22.71"N, 14°45'2.24"E). Due to leaks in petroleum storage tanks and jet fuelling stations over years of active use the site was heavily contaminated with petroleum hydrocarbons, until the base was closed in 1991. This site is one of the most important sources of high quality groundwater in the Czech Republic. During remediation processes the groundwater level in the sediments fluctuated, driving the hydrocarbon contaminants to lower depth levels along with the groundwater and leading to magnetite formation (Rijal et al., Environ.Pollut., 158, 1756-1762, 2010). In our study we drilled triplicate cores at three locations which were studied earlier. Magnetic susceptibility (MS) profiles combined with other magnetic properties were analyzed to obtain the ferro(i)magnetic concentration distributions along the depth sections. Additionally the sediment properties, hydrocarbon content and bacterial activity were studied. The triplicate cores were used to statistically discriminate outliers and to recognize significant magnetic signatures with depth. The results show that the highest concentration of ferrimagnetic phases (interpreted as newly formed magnetite) exists at the probable top of the groundwater fluctuation (GWF) zone. For example at one of the sites this zone is found between 1.4-1.9 m depth (groundwater table at ~2.3 m depth). High S-ratio and the correlation of ARM with MS values confirm the contribution of magnetite for the ferro(i)magnetic enhancement in the GWF zone. In the previous studies the MS signals revealed small-scale isolated features, but with the use of triplicate cores significant trends of MS could be identified, showing an increase from the lowermost position of the groundwater table upward. Bacterial activity is likely responsible for magnetite formation in this depth range as indicated by most probable number (MPN) results of iron-reducing bacteria.
Structural phase transition of as-synthesized Sr-Mn nanoferrites by annealing temperature
NASA Astrophysics Data System (ADS)
Amer, M. A.; Meaz, T. M.; Attalah, S. S.; Ghoneim, A. I.
2015-11-01
The Sr0.2Mn0.8Fe2O4 nanoparticle ferrites were synthesized by the co-precipitation method and annealed at different temperatures T. XRD, TEM, FT-IR, VSM and Mössbauer techniques were used to characterize the samples. This study proved that the structural phase of nanoferrites was transformed from cubic spinel for T≤500 °C to Z-type hexagonal for T≥700 °C. The structural transformation was attributed to Jahn-Teller effect of the Mn3+ ions and/or atomic disorder existed in the crystal lattice. The obtained spectra and parameters for the samples were affected by the transformation process. The lattice constant a showed a splitting to a and c for T>500 °C. The lattice constant c, grain and crystallite size R, strain, octahedral B-site band position and force constant, Debye temperature, coercivity Hc, remnant magnetization, squareness and magnetic moment, spontaneous magnetization and hyperfine magnetic fields showed increase against T. The lattice constant a, distortion and dislocation parameters, specific surface area, tetrahedral A-site band position and force constant, threshold frequency, Young's and bulk moduli, saturation magnetization Ms, area ratio of B-/A-sites, A-site line width were decreased with T. Experimental and theoretical densities, porosity, Poison ratio, stiffness constants, rigidity modulus, B-site line width and spontaneous magnetization showed dependence on T, whereas Ms and Hc proved dependence on R.
NASA Astrophysics Data System (ADS)
Sitharaman, Balaji; Jacobson, Barry D.; Wadghiri, Youssef Z.; Bryant, Henry; Frank, Joseph
2013-04-01
We report the magnetic behavior, relaxometry, phantom magnetic resonance imaging (MRI), and near-infrared (NIR) photoluminescence spectroscopy of gadolinium (Gd) catalyzed single-walled carbon nanotubes (Gd-SWCNTs). Gd-SWCNTs are paramagnetic with an effective magnetic moment of 7.29 μB. Gd-SWCNT solutions show high r1 and r2 relaxivities at very low (0.01 MHz) to clinically relevant (61 MHz) magnetic fields (r1 ≥ 130 mM-1 s-1, r2 ≥ 160 mM-1 s-1). Analysis of nuclear magnetic resonance dispersion profiles using Solomon, Bloembergen, and Morgan equations suggests that multiple structural and dynamic parameters such as rotational correlation time τR, rate of water exchange τM, and the number of fast-exchanging water molecules within the inner sphere q may be responsible for the increase in r1 and r2 relaxivity. The T1 weighted MRI signal intensity (gradient echo sequence; repetition time (TR) = 66 ms, echo time (TE) = 3 ms, flop angle = 108°) of Gd-SWCNT phantom solution is 14 times greater than the Gd-based clinical MRI contrast agent Magnevist. Additionally, these nanotubes exhibit near infrared fluorescence with distinct E11 transitions of several semiconducting SWCNTs. Taken together, these results demonstrate that Gd-SWCNTs have potential as a novel, highly efficacious, multimodal MRI-NIR optical imaging contrast agent.
Kayili, H Mehmet; Salih, Bekir
2016-08-01
Hydrophobic silicon-based material having magnetic properties was fairly synthesized by a classical sol-gel approach. Pepsin enzyme was encapsulated in the sol-gel material and the enzyme activity was evaluated in consequence of the digestion of some common proteins such as α- and β-casein, cytochrome c, myoglobin, and bovine serum albumin (BSA) both in a single protein batch and in the protein mixture. The optimum digestion time of the studied proteins using pepsin-encapsulated magnetic sol-gel material was found to be 20min. To produce the magnetic sol-gel material for convenient and easy proteomics applications, Fe3O4 was doped inside sol-gel material during the gelation step. It was observed that the activity of encapsulated pepsin was not affected by the amount of Fe3O4. Poly(ethylene glycol) was also inserted in sol-gel bulk to obtain suitable roughness and increase the hydrophilicity of the material surface to let protein molecules reach to the sol-gel material easily. The digestion of the protein mixture and non-fat bovine milk was performed with the pepsin-encapsulated magnetic sol-gel material and the digested solutions were analyzed using SDS-PAGE, MALDI-TOF-MS and LC-MS/MS for the protein identification. Reusability of the pepsin-encapsulated sol-gel material was examined and it was determined that they could be used at least 20 times. Finally, IgG digestions with a fast incubation time period were carried out using pepsin-encapsulated sol-gel material for generation of (Fab)2 product to evaluate the kinetic performance of the material. Copyright © 2016 Elsevier B.V. All rights reserved.
Fischer, Christin; Kallinich, Constanze; Klockmann, Sven; Schrader, Jil; Fischer, Markus
2016-12-07
The present work demonstrates the first automated enrichment approach for antibiotics in milk using specific DNA aptamers. First, aptamers toward the antibiotic sulfanilamide were selected and characterized regarding their dissociation constants and specificity toward relevant antibiotics via fluorescence assay and LC-MS/MS detection. The performed enrichment was automated using the KingFisherDuo and compared to a manual approach. Verifying the functionality, trapping was realized in different milk matrices: (i) 0.3% fat milk, (ii) 1.5% fat milk, (iii) 3.5% fat milk, and (iv) 0.3% fat cocoa milk drink. Enrichment factors up to 8-fold could be achieved. Furthermore, it could be shown that novel implementation of a magnetic separator increases the reproducibility and reduces the hands-on time from approximately half a day to 30 min.
Micro structural analysis and magnetic characteristics of rare earth substituted cobalt ferrite
NASA Astrophysics Data System (ADS)
Tapdiya, Swati; Singh, Sarika; Kulshrestha, Shobha; Shrivastava, A. K.
2018-05-01
A series of ultrafine nanoparticles of Gd3+ doped Co-ferrites CoGdxFe2-xO4 (x=0.0, 0.05 and 0.10) were prepared by wet chemical co-precipitation method using nitrates of respective metal ions. Structural and morphology studies were performed using XRD, SEM and EDAX. Indexed XRD patterns confirm the formation of cubic spinel phase. Average crystallite sizes found to be decreases with trivalent rare earth ion substitution. Lattice constant (a) and lattice strain increases with increase in Gd3+ concentration due to large ionic radii (0.94nm) of Gd3+ replacing Fe3+ (0.64nm). SEM images show the spherical morphology and uniform growth of nanoparticles. Magnetic studies show that magnetization (Ms), decreases with increase in Gd3+ concentration from 50.16 emu/gm to 31.26 emu/gm.
NASA Technical Reports Server (NTRS)
Sieradski, L. M.; Giffin, C. E.; Nier, A. O. (Inventor)
1976-01-01
A mass spectrometer (MS) with unique magnetic pole pieces which provide a homogenous magnetic field across the gap of the MS magnetic sector as well as the magnetic field across an ion-type vacuum pump is disclosed. The pole pieces form the top and bottom sides of a housing. The housing is positioned so that portions of the pole pieces form part of the magnetic sector with the space between them defining the gap region of the magnetic sector, through which an ion beam passes. The pole pieces extend beyond the magnetic sector with the space between them being large enough to accommodate the electrical parts of an ion-type vacuum pump. The pole pieces which provide the magnetic field for the pump, together with the housing form the vacuum pump enclosure or housing.
Theory of magnetic enhancement in strontium hexaferrite through Zn-Sn pair substitution
DOE Office of Scientific and Technical Information (OSTI.GOV)
Liyanage, LSI; Kim, S; Hong, YK
2013-12-01
We study the site occupancy and magnetic properties of Zn-Sn substituted M-type Sr-hexaferrite SrFe12-x(Zn0.5Sn0.5)(x)O-19 with x=1 using first-principles total-energy calculations. We find that in the lowest-energy configuration Zn2+ and Sn4+ ions preferentially occupy the 4f(1) and 4f(2) sites, respectively, in contrast to the model previously suggested by Ghasemi et al. [J. Appl. Phys, 107, 09A734 (2010)], where Zn2+ and Sn4+ ions occupy the 2b and 4f(2) sites. Density-functional theory calculations show that our model has a lower total energy by more than 0.2 eV per unit cell compared to Ghasemi's model. More importantly, the latter does not show an increasemore » in saturation magnetization (M-s) compared to the pure M-type Sr-hexaferrite, in disagreement with the experiment. On the other hand, our model correctly predicts a rapid increase in M-s as well as a decrease in magnetic anisotropy compared to the pure M-type Sr-hexaferrite, consistent with experimental measurements. (c) 2013 Elsevier B.V. All rights reserved.« less
MRI in multiple sclerosis: current status and future prospects
Bakshi, Rohit; Thompson, Alan J; Rocca, Maria A; Pelletier, Daniel; Dousset, Vincent; Barkhof, Frederik; Inglese, Matilde; Guttmann, Charles R G; Horsfield, Mark A; Filippi, Massimo
2008-01-01
Many promising MRI approaches for research or clinical management of multiple sclerosis (MS) have recently emerged, or are under development or refinement. Advanced MRI methods need to be assessed to determine whether they allow earlier diagnosis or better identification of phenotypes. Improved post-processing should allow more efficient and complete extraction of information from images. Magnetic resonance spectroscopy should improve in sensitivity and specificity with higher field strengths and should enable the detection of a wider array of metabolites. Diffusion imaging is moving closer to the goal of defining structural connectivity and, thereby, determining the functional significance of lesions at specific locations. Cell-specific imaging now seems feasible with new magnetic resonance contrast agents. The imaging of myelin water fraction brings the hope of providing a specific measure of myelin content. Ultra-high-field MRI increases sensitivity, but also presents new technical challenges. Here, we review these recent developments in MRI for MS, and also look forward to refinements in spinal-cord imaging, optic-nerve imaging, perfusion MRI, and functional MRI. Advances in MRI should improve our ability to diagnose, monitor, and understand the pathophysiology of MS. PMID:18565455
DOE Office of Scientific and Technical Information (OSTI.GOV)
Yee, S; Ionascu, D; Wilson, G
2014-06-01
Purpose: In pre-clinical trials of cancer thermotherapy, hyperthermia can be induced by exposing localized super-paramagnetic iron oxide nanoparticles (SPION) to external alternating magnetic fields generated by a solenoid electrical circuit (Zhao et al., Theranostics 2012). Alternatively, an RF pulse technique implemented in a regular MRI system is explored as a possible hyperthermia induction technique . Methods: A new thermal RF pulse sequence was developed using the Philips pulse programming tool for the 3T Ingenia MRI system to provide a sinusoidal magnetic field alternating at the frequency of 1.43 kHz (multiples of sine waves of 0.7 ms period) before each excitationmore » RF pulse for imaging. The duration of each thermal RF pulse routine was approximately 3 min, and the thermal pulse was applied multiple times to a phantom that contains different concentrations (high, medium and low) of SPION samples. After applying the thermal pulse each time, the temperature change was estimated by measuring the phase changes in the T1-weighted inversion-prepared multi-shot turbo field echo (TFE) sequence (TR=5.5 ms, TE=2.7 ms, inversion time=200 ms). Results: The phase values and relative differences among them changed as the number of applied thermal RF pulses increased. After the 5th application of the thermal RF pulse, the relative phase differences increased significantly, suggesting the thermal activation of the SPION. The increase of the phase difference was approximately linear with the SPION concentration. Conclusion: A sinusoidal RF pulse from the MRI system may be utilized to selectively thermally activate tissues containing super-paramagnetic iron oxide nanoparticles.« less
Brand, Judith; Köpke, Sascha; Kasper, Jürgen; Rahn, Anne; Backhus, Imke; Poettgen, Jana; Stellmann, Jan-Patrick; Siemonsen, Susanne; Heesen, Christoph
2014-01-01
Magnetic resonance imaging (MRI) is a key diagnostic and monitoring tool in multiple sclerosis (MS) management. However, many scientific uncertainties, especially concerning correlates to impairment and prognosis remain. Little is known about MS patients' experiences, knowledge, attitudes, and unmet information needs concerning MRI. We performed qualitative interviews (n = 5) and a survey (n = 104) with MS patients regarding MRI patient information, and basic MRI knowledge. Based on these findings an interactive training program of 2 hours was developed and piloted in n = 26 patients. Interview analyses showed that patients often feel lost in the MRI scanner and left alone with MRI results and images while 90% of patients in the survey expressed a high interest in MRI education. Knowledge on MRI issues was fair with some important knowledge gaps. Major information interests were relevance of lesions as well as the prognostic and diagnostic value of MRI results. The education program was highly appreciated and resulted in a substantial knowledge increase. Patients reported that, based on the program, they felt more competent to engage in encounters with their physicians. This work strongly supports the further development of an evidence-based MRI education program for MS patients to enhance participation in health-care.
Kauv, Paul; Ayache, Samar S; Créange, Alain; Chalah, Moussa A; Lefaucheur, Jean-Pascal; Hodel, Jérôme; Brugières, Pierre
2017-01-01
Phosphorus magnetic resonance spectroscopy (31P-MRS) has previously shown abnormal changes in energy metabolites in the brain of multiple sclerosis (MS) patients. However, the relationship between these energy metabolites - particularly adenosine triphosphate (ATP) - and the disease severity remains unclear. The objective of this study was to determine whether measuring ATP metabolites can help to predict disease severity in MS patients. 31P-MRS at 3 tesla was performed in 9 relapsing remitting (RRMS), 9 secondary progressive MS patients (SPMS), and 10 age-matched healthy controls. ATP metabolites (expressed as %) in normally appearing white matter of the centrum semiovale were compared between patients and healthy controls. The relationship between Expanded Disability Status Scale (EDSS) and ATP metabolites was evaluated. RRMS and SPMS patients had higher phosphocreatine (PCr) and lower phosphodiesters than healthy controls. In addition, RRMS patients had higher β-ATP% than SPMS patients. β-ATP% was negatively correlated with EDSS in all patients. Our findings suggest a defective PCr metabolism in both patient groups, and a higher state of energy production in RRMS that might reflect a compensatory mechanism in face of the increased needs. The correlation of β-ATP with EDSS makes it a candidate biomarker for assessing MS disease severity. © 2017 S. Karger AG, Basel.
Transcranial magnetic stimulation primes the effects of exercise therapy in multiple sclerosis.
Mori, Francesco; Ljoka, Concetta; Magni, Elisabetta; Codecà, Claudia; Kusayanagi, Hajime; Monteleone, Fabrizia; Sancesario, Andrea; Bernardi, Giorgio; Koch, Giacomo; Foti, Calogero; Centonze, Diego
2011-07-01
Exercise therapy (ET) can be beneficial in disabled multiple sclerosis (MS) patients. Intermittent transcranial magnetic theta burst stimulation (iTBS) induces long-term excitability changes of the cerebral cortex and may ameliorate spasticity in MS. We investigated whether the combination of iTBS and a program of ET can improve motor disability in MS patients. In a double-blind, sham-controlled trial, 30 participants were randomized to three different interventions: iTBS plus ET, sham stimulation plus ET, and iTBS alone. Before and after 2 weeks of treatment, measures of spasticity through the modified Ashworth scale (MAS) and the 88 items Multiple Sclerosis Spasticity Score questionnaire (MSSS-88), fatigue through the Fatigue Severity Scale (FSS), daily living activities (ADL) through the Barthel index and health-related quality of life (HRQoL) through the 54 items Multiple Sclerosis Quality of life inventory (MSQoL-54) were collected. iTBS plus ET reduced MAS, MSSS-88, FSS scores, while in the Barthel index and MSQoL-54, physical composite scores were increased. iTBS alone caused a reduction of the MAS score, while none of the measured scales showed significant changes after sham iTBS plus ET. iTBS associated with ET is a promising tool for motor rehabilitation of MS patients.
Magnetic Signature of Glacial Flour in Sediments From Bear Lake, Utah/Idaho
NASA Astrophysics Data System (ADS)
Rosenbaum, J. G.; Dean, W. E.; Colman, S. M.; Reynolds, R. L.
2002-12-01
Variations in magnetic properties within an interval of Bear Lake sediments correlative with oxygen isotope stage 2 (OIS 2) and OIS 3 provide a record of glacial flour production for the Uinta Mountains. Like sediments of the same age from Upper Klamath Lake (OR), these Bear Lake sediments have high magnetic susceptibilities (MS) relative to non-glacial-age sediments and contain well-defined millennial-scale variations in magnetic properties. In contrast to glacial flour derived from volcanic rocks surrounding Upper Klamath Lake, glacial flour derived from the Uinta Mountains and deposited in Bear Lake by the Bear River has low magnetite content but high hematite content. The relatively low MS values of younger and older non-glacial-age sediments are due entirely to dilution by non-magnetic endogenic carbonate and to the effects of sulfidic alteration of detrital Fe-oxides. Analysis of samples from streams entering Bear Lake and from along the course of the Bear River demonstrates that, in comparison to other areas of the catchment, sediment derived from the Uinta Mountains is rich in hematite (high HIRM) and aluminum, and poor in magnetite (low MS) and titanium. Within the glacial-age lake sediments, there are strong positive correlations among HIRM, Al/Ti, and fine sediment grain size. MS varies inversely with theses three variables. These relations indicate that the observed millennial-scale variations in magnetic and chemical properties arise from varying proportions of two detrital components: (1) very fine-grained glacial flour derived from Proterozoic metasedimentary rocks in the Uinta Mountains and characterized by high HIRM and low MS, and (2) somewhat coarser material, characterized by higher MS and lower HIRM, derived from widespread sedimentary rocks along the course of the Bear River and around Bear Lake. Measurement of glacial flour incorporated in lake sediments can provide a continuous history of alpine glaciation, because the rate of accumulation of glacial flour probably varies closely with the areal extent of glaciation. In the absence of post-depositional alteration of magnetic minerals, magnetic measurements can provide a highly sensitive tool for assessing variations in glacial flour content if glacial and non-glacial materials have contrasting magnetic properties. For Bear Lake, the required contrast is produced by differences in bedrock underlying glaciated and unglaciated areas.
Sheth, Vipul R.; Fan, Shujuan; He, Qun; Ma, Yajun; Annesse, Jacopo; Switzer, Robert; Corey-Bloom, Jody; Bydder, Graeme M; Du, Jiang
2017-01-01
Multiple sclerosis (MS)causes demyelinating lesions in the white matter and increased iron deposition in the subcortical gray matter. Myelin protons have an extremely short T2* (less than 1 ms) and are not directly detected with conventional clinical magnetic resonance (MR) imaging sequences. Iron deposition also reduces T2*, leading to reduced signal on clinical sequences. In this study we tested the hypothesis that the inversion recovery ultrashort echo time (IR-UTE) pulse sequence can directly and simultaneously image myelin and iron deposition using a clinical 3T scanner. The technique was first validated on a synthetic myelinphantom (myelin powder in D2O) and a Feridex iron phantom. This was followed by studies of cadaveric MS specimens, healthy volunteers and MS patients. UTE imaging of the synthetic myelin phantom showed an excellent bi-component signal decay with two populations of protons, one with a T2* of 1.2 ms (residual water protons) and the other with a T2* of 290 μs (myelin protons). IR-UTE imaging shows sensitivity to a wide range of iron concentrations from 0.5 to ∼30 mM. The IR-UTE signal from white matter of the brain of healthy volunteers shows a rapid signal decay with a short T2* of ∼300 μs, consistent with the T2* values of myelin protons in the synthetic myelin phantom. IR-UTE imaging in MS brain specimens and patients showed multiple white matter lesions as well as areas of high signal in subcortical gray matter. This in specimens corresponded in position to Perl's diaminobenzide staining results, consistent with increased iron deposition. IR-UTE imaging simultaneously detects lesions with myelin loss in the white matter and iron deposition in the gray matter. PMID:28038965
Kumar, Sudershan; Vashisht, Hemlata; Olasunkanmi, Lukman O.; Bahadur, Indra; Verma, Hemant; Singh, Gurmeet; Obot, Ime B.; Ebenso, Eno E.
2016-01-01
Polyurethane based tri-block copolymers namely poly(N-vinylpyrrolidone)-b-polyurethane-b-poly(N-vinylpyrrolidone) (PNVP-PU) and poly(dimethylaminoethylmethacrylate)-b-polyurethane-b-poly(dimethylaminoethylmethacrylate) (PDMAEMA-PU) were synthesized through atom transfer radical polymerization (ATRP) mechanism. The synthesized polymers were characterized using nuclear magnetic resonance (NMR) spectroscopy and gel permeation chromatography (GPC) methods. The corrosion inhibition performances of the compounds were investigated on mild steel (MS) in 0.5 M H2SO4 medium using electrochemical measurements, surface analysis, quantum chemical calculations and molecular dynamic simulations (MDS). Potentiodynamic polarization (PDP) measurements revealed that the polymers are mixed-type corrosion inhibitors. Electrochemical impedance spectroscopy (EIS) measurements showed that the polymers inhibit MS corrosion by adsorbing on MS surface to form pseudo-capacitive interface. The inhibitive effects of the polymers increase with increasing concentration and decrease with increasing temperature. The adsorption of both the polymers on MS surface obey the Langmuir adsorption isotherm and involves both physisorption and chemisorption mechanisms. Scanning electron microscopy (SEM) and atomic force microscopy (AFM) analyses showed that the polymers formed protective film on MS surface and shield it from direct acid attack. Quantum chemical calculations and molecular dynamic simulations studies corroborate experimental results. PMID:27515383
Characterization of magnetically enhanced buried soil layer in arid environment
NASA Astrophysics Data System (ADS)
Petrovsky, E.; Grison, H.; Kapicka, A.; Silva, P. F.; Font, E.
2011-12-01
Magnetic susceptibility (MS) of soils, reflecting the presence of magnetite/maghemite, can be used in several environmental applications. Magnetic topsoil mapping is often used to outline areas polluted by atmospherically deposited dust. However, in these studies, the magnetically enhanced layer is usually shallow, some 5-6 cm under the surface. In our contribution, we present the case when the magnetic susceptibility is enhanced in deeper soil layers. Investigated soils are mostly sandy soils, from several localities in Portugal, in a zone with arid climate. Sample profiles were collected always in forests or forest stands with pines, cork oaks or eucalyptus trees in two areas: around the city of Sines (on the coast south of Lisbon) and around the city of Abrantes (inland, north-east of Lisbon). Both areas are presumably affected by one major source of pollution - power plant. Surface magnetic susceptibility measurements were performed by Bartington MS2D loop; values vary from 10 to 300 x 10-5 SI units. Vertical distribution of magnetic susceptibility was measured already in situ using the SM400 (ZHInstruments) on profiles about 40cm in length. Mass-specific MS was determined using Bartington MS2B dual frequency meter and Agico MFK1. Nine vertical profiles were selected for detailed analyses including the ARM, IRM and hysteresis measurements. Distinctly enhanced magnetic layers were detected in deeper horizons. This enhancement can be ascribed to several mechanisms. Migration of magnetic particles seems to be probable, as observed in our model experiments with sand columns. In coastal areas, the enhanced layer could be due to tsunami deposits, as described in other areas. Finally, in particular at sites close to power plants, the construction works followed by surface remediation have to be also considered as one of the possible mechanisms.
NASA Astrophysics Data System (ADS)
Kondo, T.; Mori, K.; Hachisu, M.; Yamazaki, T.; Okamoto, D.; Watanabe, M.; Gonda, K.; Tada, H.; Hamada, Y.; Takano, M.; Ohuchi, N.; Ichiyanagi, Y.
2015-05-01
Mn-Zn ferrite, Mn1-xZnxFe2O4 nanoparticles encapsulated in amorphous SiO2 were prepared using our original wet chemical method. X-ray diffraction patterns confirmed that the diameters of these particles were within 7-30 nm. Magnetization measurements for various sample compositions revealed that the saturation magnetization (Ms) of 7 nm particles was maximum for the x = 0.2 sample. AC magnetic susceptibility measurements were performed for Mn0.8Zn0.2Fe2O4 (x = 0.2) samples with 13-30 nm particles. The peak of the imaginary part of the magnetic susceptibility χ″ shifted to higher temperatures as the particle size increased. An AC field was found to cause the increase in temperature, with the 18 nm particles exhibiting the highest temperature increase, as expected. In addition, in vitro experiments were carried out to study the hyperthermia effects of Mn1-xZnxFe2O4 (x = 0.2, 18 nm) particles on human cancer cells.
Magnetic properties changes due to hydrocarbon contaminated groundwater table fluctuations
NASA Astrophysics Data System (ADS)
Ameen, Nawrass
2013-04-01
This study aims to understand the mechanisms and conditions which control the formation and transformation of ferro(i)magnetic minerals caused by hydrocarbon contaminated groundwater, in particular in the zone of fluctuating water levels. The work extends previous studies conducted at the same site. The study area is a former military air base at Hradčany, Czech Republic (50°37'22.71"N, 14°45'2.24"E). The site was heavily contaminated with petroleum hydrocarbons, due to leaks in petroleum storage tanks and jet fuelling stations over years of active use by the Soviet Union, which closed the base in 1991. The site is one of the most important sources of high quality groundwater in the Czech Republic. In a previous study, Rijal et al. (2010) concluded that the contaminants could be flushed into the sediments as the water level rose due to remediation processes leading to new formation of magnetite. In this previous study three different locations were investigated; however, from each location only one core was obtained. In order to recognize significant magnetic signatures versus depth three cores from each of these three locations were drilled in early 2012, penetrating the unsaturated zone, the groundwater fluctuation (GWF) zone and extending to about one meter below the groundwater level (~2.3 m depth at the time of sampling). Magnetic susceptibility (MS) profiles combined with other magnetic properties were analyzed to obtain a significant depth distribution of the ferro(i)magnetic concentration. Sediment properties, hydrocarbon content and bacterial activity were additionally studied. The results show that the highest ferrimagnetic mineral concentrations exist between 1.4-1.9 m depth from the baseline which is interpreted as the top of the GWF zone. Spikes of MS detected in the previous studies turned out to represent small-scale isolated features, but the trend of increasing MS values from the lowermost position of the groundwater table upward was verified. Mineral magnetic parameters indicate that magnetite is responsible for the MS signal which confirms the previous results (Rijal et al., 2010). The so far existing uncertainty of the groundwater level position could be solved. Bacterial activity is studied at particular depth horizons as it is assumed to be responsible for iron mineralogy changes. References: Rijal M.L., Appel E., Petrovský E. and Blaha U., 2010. Change of magnetic properties due to fluctuations of hydrocarbon contaminated groundwater in unconsolidated sediments. Environ.Pollut., 158, 1756-1762.
Angelini, Daniela F.; Serafini, Barbara; Piras, Eleonora; Severa, Martina; Coccia, Eliana M.; Rosicarelli, Barbara; Ruggieri, Serena; Gasperini, Claudio; Buttari, Fabio; Centonze, Diego; Mechelli, Rosella; Salvetti, Marco; Borsellino, Giovanna; Aloisi, Francesca; Battistini, Luca
2013-01-01
It has long been known that multiple sclerosis (MS) is associated with an increased Epstein-Barr virus (EBV) seroprevalence and high immune reactivity to EBV and that infectious mononucleosis increases MS risk. This evidence led to postulate that EBV infection plays a role in MS etiopathogenesis, although the mechanisms are debated. This study was designed to assess the prevalence and magnitude of CD8+ T-cell responses to EBV latent (EBNA-3A, LMP-2A) and lytic (BZLF-1, BMLF-1) antigens in relapsing-remitting MS patients (n = 113) and healthy donors (HD) (n = 43) and to investigate whether the EBV-specific CD8+ T cell response correlates with disease activity, as defined by clinical evaluation and gadolinium-enhanced magnetic resonance imaging. Using HLA class I pentamers, lytic antigen-specific CD8+ T cell responses were detected in fewer untreated inactive MS patients than in active MS patients and HD while the frequency of CD8+ T cells specific for EBV lytic and latent antigens was higher in active and inactive MS patients, respectively. In contrast, the CD8+ T cell response to cytomegalovirus did not differ between HD and MS patients, irrespective of the disease phase. Marked differences in the prevalence of EBV-specific CD8+ T cell responses were observed in patients treated with interferon-β and natalizumab, two licensed drugs for relapsing-remitting MS. Longitudinal studies revealed expansion of CD8+ T cells specific for EBV lytic antigens during active disease in untreated MS patients but not in relapse-free, natalizumab-treated patients. Analysis of post-mortem MS brain samples showed expression of the EBV lytic protein BZLF-1 and interactions between cytotoxic CD8+ T cells and EBV lytically infected plasma cells in inflammatory white matter lesions and meninges. We therefore propose that inability to control EBV infection during inactive MS could set the stage for intracerebral viral reactivation and disease relapse. PMID:23592979
Norouzi, Samira; Khademi, Hossein; Cano, Angel Faz; Acosta, Jose A
2016-05-15
Tree leaves are considered as one of the best biogenic dust collectors due to their ability to trap and retain particulate matter on their surfaces. In this study, the magnetic susceptibility (MS) and the concentration of selected heavy metals of plane tree (Platanus orientalis L.) leaves and deposited atmospheric dust, sampled by an indirect and a direct method, respectively, were determined to investigate the relationships between leaf magnetic parameters and the concentration of heavy metals in deposited atmospheric dust. The objective was to develop a biomagnetic method as an alternative to the common ones used for determining atmospheric heavy metal contaminations. Plane tree leaves were monthly sampled on the 19th of May to November, 2012 (T1-T7), for seven months from 21 different sites in the city of Isfahan, central Iran. Deposited atmospheric dust samples were also collected using flat glass surfaces from the same sites on the same dates, except for T1. MS (χlf, χhf) values in washed (WL) and unwashed leaves (UL) as well as Cu, Fe, Mn, Ni, Pb, and Zn concentrations in UL and deposited atmospheric dust samples were determined. The results showed that the MS content with a biogenic source was low with almost no significant change during the sampling period, while an increasing trend was observed in the MS content of UL samples due to the deposition of heavy metals and magnetic particles on leaf surfaces throughout the plant growth. The latter type of MS content could be reduced through washing off by rain. Most heavy metals examined, as well as the Tomlinson pollution load index (PLI) in UL, showed statistically significant correlations with MS values. The correlation between heavy metals content in atmospheric dust deposited on glass surfaces and leaf MS values was significant for Cu, Fe, Pb, and Zn. Moreover, the similarity observed between the spatial distribution maps of leaf MS and deposited atmospheric dust PLI provided convincing evidence regarding the suitability of the biomagnetic approach as a relatively rapid and inexpensive method for identifying highly polluted urban areas with selected heavy metals, especially those subjected to anthropogenic and other traffic related sources. Copyright © 2016 Elsevier Ltd. All rights reserved.
Plasma Rotation During Neutral Beam Injection In MST
NASA Astrophysics Data System (ADS)
Hudson, Ben; Ding, W.; Fiksel, G.; Prager, S.; Yates, T.
2006-10-01
The effect of fast ions from neutral beam injection (20 keV, 30 A, 1.5 ms) on plasma rotation and magnetic tearing modes is studied. We observe that during co-injected NBI (with the injection in the same direction as the plasma and mode rotation) the rotation of the core-resonant n = 5 magnetic mode decreases and in many instances lock to the vessel wall. There is an associated drop in the poloidal component of n = 5 magnetic mode amplitude. The drop in the mode velocity suggests a counter-directed torque, perhaps due to modification of the radial electric field. The rotation slows during the injection phase, then restores itself on the timescale of the fast ion slowing down time (5 ms @ Te = 100 eV). The fluctuation-induced j x b Maxwell stress is measured using MST's FIR diagnostic and presented for comparison. Equilibrium reconstruction suggests a small increase in on-axis J||, consistent with the presence of a localized fast ion population moving in the direction of the plasma current. Mode rotation during NBI counter-injection is also presented.
Dynamic mapping of the human visual cortex by high-speed magnetic resonance imaging.
Blamire, A M; Ogawa, S; Ugurbil, K; Rothman, D; McCarthy, G; Ellermann, J M; Hyder, F; Rattner, Z; Shulman, R G
1992-01-01
We report the use of high-speed magnetic resonance imaging to follow the changes in image intensity in the human visual cortex during stimulation by a flashing checkerboard stimulus. Measurements were made in a 2.1-T, 1-m-diameter magnet, part of a Bruker Biospec spectrometer that we had programmed to do echo-planar imaging. A 15-cm-diameter surface coil was used to transmit and receive signals. Images were acquired during periods of stimulation from 2 s to 180 s. Images were acquired in 65.5 ms in a 10-mm slice with in-plane voxel size of 6 x 3 mm. Repetition time (TR) was generally 2 s, although for the long flashing periods, TR = 8 s was used. Voxels were located onto an inversion recovery image taken with 2 x 2 mm in-plane resolution. Image intensity increased after onset of the stimulus. The mean change in signal relative to the prestimulation level (delta S/S) was 9.7% (SD = 2.8%, n = 20) with an echo time of 70 ms. Irrespective of the period of stimulation, the increase in magnetic resonance signal intensity was delayed relative to the stimulus. The mean delay measured from the start of stimulation for each protocol was as follows: 2-s stimulation, delay = 3.5 s (SD = 0.5 s, n = 10) (the delay exceeds stimulus duration); 20- to 24-s stimulation, delay = 5 s (SD = 2 s, n = 20). PMID:1438317
Horizontal nystagmus and multiple sclerosis using 3-Tesla magnetic resonance imaging.
Iyer, P M; Fagan, A J; Meaney, J F; Colgan, N C; Meredith, S D; Driscoll, D O; Curran, K M; Bradley, D; Redmond, J
2016-11-01
Nystagmus in patients with multiple sclerosis (MS) is generally attributed to brainstem disease. Lesions in other regions may result in nystagmus. The identification of these other sites is enhanced by using 3-Tesla magnetic resonance imaging (3TMRI) due to increased signal-to-noise ratio. We sought to evaluate the distribution of structural lesions and disruption of tracts in patients with horizontal nystagmus secondary to MS using 3TMRI. Twenty-four patients (20 women, 4 men; age range 26-55 years) with horizontal nystagmus secondary to MS underwent 3TMRI brain scans; and 18 patients had diffusion tensor imaging (DTI) for tractography. Nystagmus was bidirectional in 11, right-sided in 6 and left-sided in 7. We identified 194 lesions in 20 regions within the neural integrator circuit in 24 patients; 140 were within the cortex and 54 were within the brainstem. Only two patients had no lesions in the cortex, and 9 had no lesions in the brainstem. There was no relationship between side of lesion and direction of nystagmus. Thirteen of 18 (72 %) had tract disruption with fractional anisotropy (FA) values below 0.2. FA was significantly lower in bidirectional compared to unidirectional nystagmus (p = 0.006). In MS patients with horizontal nystagmus, lesions in all cortical eye fields and their descending connections were evident. Technical improvements in tractography may help identify the specific site(s) resulting in nystagmus in MS.
2016-02-02
Earths ”, MS&T15-Materials Science and Technology 2015 Conference, Columbus, Ohio, October 4-8, 2015. 3. Dulikrvich, G.S., Reddy, S., Orlande, H.R.B...Schwartz, J.and Koch, C.C., “Multi-Objective Design and Optimization of Hard Magnetic Alloys Free of Rare Earths ”, MS&T15-Materials Science and Technology...AFRL-AFOSR-VA-TR-2016-0091 (BRI) Direct and Inverse Design Optimization of Magnetic Alloys with Minimized Use of Rare Earth Elements George
Ustohal, Libor; Mayerova, Michaela; Hublova, Veronika; Prikrylova Kucerova, Hana; Ceskova, Eva; Kasparek, Tomas
2017-04-01
Schizophrenia is accompanied by impaired cortical inhibition, as measured by several markers including the cortical silent period (CSP). It is thought that CSP measures gamma-aminobutyric acid receptors B (GABA B ) mediated inhibitory activity. But the mutual roles of schizophrenia as a disease and the drugs used for the treatment of psychosis on GABA mediated neurotransmission are not clear. We recruited 13 drug-naive patients with first-episode schizophrenia. We used transcranial magnetic stimulation to assess CSP prior to initiating risperidone monotherapy and again four weeks later. At the same time, we rated the severity of psychopathology using the Positive and Negative Syndrome Scale (PANSS). We obtained data from 12 patients who showed a significant increase in CSP, from 134.20±41.81 ms to 162.95±61.98 ms ( p=0.041; Cohen's d=0.544). After the treatment, the PANSS total score was significantly lower, as were the individual subscores ( p<0.05). However, no correlation was found between ΔCSP and ΔPANSS. Our study in patients with first-episode schizophrenia demonstrated an association between risperidone monotherapy and an increase in GABA B mediated inhibitory neurotransmission.
Canted ferrimagnetism in Ca2+Sc3+ substituted yttrium-iron-garnet
NASA Astrophysics Data System (ADS)
Pardavi-Horváth, M.; Thavendrarajah, A.; Wigen, P. E.; DeGasperis, P.
1988-11-01
The temperature dependence of the magnetization of Y3-y-zCayLuzFe5-xScxO12 (0.6≤x≤1.2, 0≤y≤0.3, 0≤z≤0.9) epitaxial garnet films was measured from 4.2 K up to the Curie temperature. For x=0.7 and T≥50 K, 4πMs is enhanced by about 10% compared to the magnetization of Sc0.7 YIG. At T<50 K, a reduction of the magnetization, increasing with increasing substitution, was observed for all the measured samples. Agreement between the experimental results and molecular field models was obtained by taking into account the canting of the unsubstituted sublattice, the presence of charge compensating Fe4+ ions, a low-temperature ordering of Fe3+ ions with less than two magnetic nearest neighbors, and assuming a lattice parameter-dependent exchange interaction ratio with d(Jdd/Jad)/da =28 nm.-1 For x=1.2 and T<10 K the magnetization can be influenced by cooling through the Curie point in a magnetic field.
Kroth, Julia; Ciolac, Dumitru; Fleischer, Vinzenz; Koirala, Nabin; Krämer, Julia; Muthuraman, Muthuraman; Luessi, Felix; Bittner, Stefan; Gonzalez-Escamilla, Gabriel; Zipp, Frauke; Meuth, Sven G; Groppa, Sergiu
2017-12-01
Currently, no unequivocal predictors of disease evolution exist in patients with multiple sclerosis (MS). Cortical atrophy measurements are, however, closely associated with cumulative disability. Here, we aim to forecast longitudinal magnetic resonance imaging (MRI)-driven cortical atrophy and clinical disability from cerebrospinal fluid (CSF) markers. We analyzed CSF fractions of albumin and immunoglobulins (Ig) A, G, and M and their CSF to serum quotients. Widespread atrophy was highly associated with increased baseline CSF concentrations and quotients of albumin and IgA. Patients with increased CSF IgA and CSF IgM showed higher functional disability at follow-up. CSF markers of blood-brain barrier integrity and specific immune response forecast emerging gray matter pathology and disease progression in MS.
Fourier transform ion cyclotron resonance mass spectrometry
NASA Astrophysics Data System (ADS)
Marshall, Alan G.
1998-06-01
As for Fourier transform infrared (FT-IR) interferometry and nuclear magnetic resonance (NMR) spectroscopy, the introduction of pulsed Fourier transform techniques revolutionized ion cyclotron resonance mass spectrometry: increased speed (factor of 10,000), increased sensitivity (factor of 100), increased mass resolution (factor of 10,000-an improvement not shared by the introduction of FT techniques to IR or NMR spectroscopy), increased mass range (factor of 500), and automated operation. FT-ICR mass spectrometry is the most versatile technique for unscrambling and quantifying ion-molecule reaction kinetics and equilibria in the absence of solvent (i.e., the gas phase). In addition, FT-ICR MS has the following analytically important features: speed (~1 second per spectrum); ultrahigh mass resolution and ultrahigh mass accuracy for analysis of mixtures and polymers; attomole sensitivity; MSn with one spectrometer, including two-dimensional FT/FT-ICR/MS; positive and/or negative ions; multiple ion sources (especially MALDI and electrospray); biomolecular molecular weight and sequencing; LC/MS; and single-molecule detection up to 108 Dalton. Here, some basic features and recent developments of FT-ICR mass spectrometry are reviewed, with applications ranging from crude oil to molecular biology.
Rapid Identification of Synthetic Cannabinoids in Herbal Incenses with DART-MS and NMR.
Marino, Michael A; Voyer, Brandy; Cody, Robert B; Dane, A John; Veltri, Mercurio; Huang, Ling
2016-01-01
The usage of herbal incenses containing synthetic cannabinoids has caused an increase in medical incidents and triggered legislations to ban these products throughout the world. Law enforcement agencies are experiencing sample backlogs due to the variety of the products and the addition of new and still-legal compounds. In our study, proton nuclear magnetic resonance (NMR) spectroscopy was employed to promptly screen the synthetic cannabinoids after their rapid, direct detection on the herbs and in the powders by direct analysis in real time mass spectrometry (DART-MS). A simple sample preparation protocol was employed on 50 mg of herbal sample matrices for quick NMR detection. Ten synthetic cannabinoids were discovered in fifteen herbal incenses. The combined DART-MS and NMR methods can be used to quickly screen synthetic cannabinoids in powder and herbal samples, serving as a complementary approach to conventional GC-MS or LC-MS methods. © 2015 American Academy of Forensic Sciences.
SILAC-Based Comparative Proteomic Analysis of Lysosomes from Mammalian Cells Using LC-MS/MS.
Thelen, Melanie; Winter, Dominic; Braulke, Thomas; Gieselmann, Volkmar
2017-01-01
Mass spectrometry-based proteomics of lysosomal proteins has led to significant advances in understanding lysosomal function and pathology. The ever-increasing sensitivity and resolution of mass spectrometry in combination with labeling procedures which allow comparative quantitative proteomics can be applied to shed more light on the steadily increasing range of lysosomal functions. In addition, investigation of alterations in lysosomal protein composition in the many lysosomal storage diseases may yield further insights into the molecular pathology of these disorders. Here, we describe a protocol which allows to determine quantitative differences in the lysosomal proteome of cells which are genetically and/or biochemically different or have been exposed to certain stimuli. The method is based on stable isotope labeling of amino acids in cell culture (SILAC). Cells are exposed to superparamagnetic iron oxide particles which are endocytosed and delivered to lysosomes. After homogenization of cells, intact lysosomes are rapidly enriched by passing the cell homogenates over a magnetic column. Lysosomes are eluted after withdrawal of the magnetic field and subjected to mass spectrometry.
Quantitative interpretation of the magnetic susceptibility frequency dependence
NASA Astrophysics Data System (ADS)
Ustra, Andrea; Mendonça, Carlos A.; Leite, Aruã; Jovane, Luigi; Trindade, Ricardo I. F.
2018-05-01
Low-field mass-specific magnetic susceptibility (MS) measurements using multifrequency alternating fields are commonly used to evaluate concentration of ferrimagnetic particles in the transition of superparamagnetic (SP) to stable single domain (SSD). In classical palaeomagnetic analyses, this measurement serves as a preliminary assessment of rock samples providing rapid, non-destructive, economical and easy information of magnetic properties. The SP-SSD transition is relevant in environmental studies because it has been associated with several geological and biogeochemical processes affecting magnetic mineralogy. MS is a complex function of mineral-type and grain-size distribution, as well as measuring parameters such as external field magnitude and frequency. In this work, we propose a new technique to obtain quantitative information on grain-size variations of magnetic particles in the SP-SSD transition by inverting frequency-dependent susceptibility. We introduce a descriptive parameter named as `limiting frequency effect' that provides an accurate estimation of MS loss with frequency. Numerical simulations show the methodology capability in providing data fitting and model parameters in many practical situations. Real-data applications with magnetite nanoparticles and core samples from sediments of Poggio le Guaine section of Umbria-Marche Basin (Italy) provide additional information not clearly recognized when interpreting cruder MS data. Caution is needed when interpreting frequency dependence in terms of single relaxation processes, which are not universally applicable and depend upon the nature of magnetic mineral in the material. Nevertheless, the proposed technique is a promising tool for SP-SSD content analyses.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Conner, Benjamin S.; McGuire, Michael A.; Veedu, Shanavas Kavungal
Here we examine the intrinsic magnetic and structural properties of the title alloys, permanent magnet materials based on the abundant rare-earth elements lanthanum and cerium, since these properties (T C, M sH a(K 1, K 2)) will set the upper limits on the quality of permanent magnet that can be fabricated from said alloys. Ce 2Co 16Ti has a high magnetic anisotropy (H a = 65 kOe) but a relatively low saturation magnetization (M s = 7.3 kG), and La 2Co 16Ti has a high Ms(9.5 kG) but Ha too low for most applications (16 kOe). Though these two end-membersmore » have previously well-known properties, changing economic conditions have made re-examination of systems containing cerium and lanthanum necessary as the economic viability of rare earth mining becomes dependent on extraction of products beyond what is currently considered useful and profitable within the rare earth elements. We find that replacing some lanthanum with cerium in La 2Co 16Ti increases H a by a factor of more than two, while decreasing M s by less than 5%. The measured Ms indicate maximum possible energy products in excess of 20 MG·Oe in these materials, which have Curie temperatures near 600 °C. Real energy products are expected to be greatest near x = 1. In conclusion, these findings identify La xCe 2-xCo 16Ti as a promising system for development of so-called gap magnets that fill the energy product gap between expensive rare-earth magnets and current non-rare earth alternatives.« less
Quantitative susceptibility mapping of multiple sclerosis lesions at various ages.
Chen, Weiwei; Gauthier, Susan A; Gupta, Ajay; Comunale, Joseph; Liu, Tian; Wang, Shuai; Pei, Mengchao; Pitt, David; Wang, Yi
2014-04-01
To assess multiple sclerosis (MS) lesions at various ages by using quantitative susceptibility mapping (QSM) and conventional magnetic resonance (MR) imaging. Retrospectively selected were 32 clinically confirmed MS patients (nine men and 23 women; 39.3 years ± 10.9) who underwent two MR examinations (interval, 0.43 years ± 0.16) with three-dimensional gradient-echo sequence from August 2011 to August 2012. To estimate the ages of MS lesions, MR examinations performed 0.3-10.6 years before study examinations were studied. Hyperintensity on T2-weighted images was used to define MS lesions. QSM images were reconstructed from gradient-echo data. Susceptibility of MS lesions and temporal rates of change were obtained from QSM images. Lesion susceptibilities were analyzed by t test with intracluster correlation adjustment and Bonferroni correction in multiple comparisons. MR imaging of 32 patients depicted 598 MS lesions, of which 162 lesions (27.1%) in 23 patients were age measurable and six (1.0%) were only visible at QSM. The susceptibilities relative to normal-appearing white matter (NAWM) were 0.53 ppb ± 3.34 for acute enhanced lesions, 38.43 ppb ± 13.0 (positive; P < .01) for early to intermediately aged nonenhanced lesions, and 4.67 ppb ± 3.18 for chronic nonenhanced lesions. Temporal rates of susceptibility changes relative to cerebrospinal fluid were 12.49 ppb/month ± 3.15 for acute enhanced lesions, 1.27 ppb/month ± 2.31 for early to intermediately aged nonenhanced lesions, and -0.004 ppb/month ± 0 for chronic nonenhanced lesions. Magnetic susceptibility of MS lesions increased rapidly as it changed from enhanced to nonenhanced, it attained a high susceptibility value relative to NAWM during its initial few years (approximately 4 years), and it gradually dissipated back to susceptibility similar to that of NAWM as it aged, which may provide new insight into pathophysiologic features of MS lesions. Online supplemental material is available for this article. RSNA, 2013
Chen, Yaqi; Chen, Zhui; Wang, Yi
2015-01-01
Screening and identifying active compounds from traditional Chinese medicine (TCM) and other natural products plays an important role in drug discovery. Here, we describe a magnetic beads-based multi-target affinity selection-mass spectrometry approach for screening bioactive compounds from natural products. Key steps and parameters including activation of magnetic beads, enzyme/protein immobilization, characterization of functional magnetic beads, screening and identifying active compounds from a complex mixture by LC/MS, are illustrated. The proposed approach is rapid and efficient in screening and identification of bioactive compounds from complex natural products.
Smith, Seth A; Farrell, Jonathan A D; Jones, Craig K; Reich, Daniel S; Calabresi, Peter A; van Zijl, Peter C M
2006-10-01
Pulsed magnetization transfer (MT) imaging has been applied to quantitatively assess brain pathology in several diseases, especially multiple sclerosis (MS). To date, however, because of the high power deposition associated with the use of short, rapidly repeating MT prepulses, clinical application has been limited to lower field strengths. The contrast-to-noise ratio (CNR) of MT is limited, and this method would greatly benefit from the use of higher magnetic fields and phased-array coil reception. However, power deposition is proportional to the square of the magnetic field and scales with coil size, and MT experiments are already close to the SAR limit at 1.5T even when smaller transmit coils are used instead of the body coil. Here we show that these seemingly great obstacles can be ameliorated by the increased T(1) of tissue water at higher field, which allows for longer maintenance of sufficiently high saturation levels while using a reduced duty cycle. This enables a fast (5-6 min) high-resolution (1.5 mm isotropic) whole-brain MT acquisition with excellent anatomical visualization of gray matter (GM) and white matter (WM) structures, and even substructures. The method is demonstrated in nine normal volunteers and five patients with relapsing remitting MS (RRMS), and the results show a clear delineation of heterogeneous lesions.
Mg1-xZnxFe2O4 nanoparticles: Interplay between cation distribution and magnetic properties
NASA Astrophysics Data System (ADS)
Raghuvanshi, S.; Mazaleyrat, F.; Kane, S. N.
2018-04-01
Correlation between cationic distribution, magnetic properties of Mg1-xZnxFe2O4 (0.0 ≤ x ≤ 1.0) ferrite is demonstrated, hardly shown in literature. X-ray diffraction (XRD) confirms the formation of cubic spinel nano ferrites with grain diameter between 40.8 to 55.4 nm. Energy dispersive spectroscopy (EDS) confirms close agreement of Mg/Fe, Zn/Fe molar ratio, presence of all elements (Mg, Zn, Fe, O), formation of estimated ferrite composition. Zn addition (for Mg) shows: i) linear increase of lattice parameter aexp, accounted for replacement of an ion with higher ionic radius (Zn > Mg); ii) presence of higher population of Fe3+ ions on B site, and unusual occurrence of Zn, Mg on A and B site leads to non-equilibrium cation distribution where we observe inverse to mixed structure, and is in contrast to reported literature where inverse to normal transition is reported; iii) effect on A-A, A-B, B-B exchange interactions, affecting coercivity Hc, Ms. A new empirical relation is also obtained showing linear relation between saturation magnetization Ms - inversion parameter δ, oxygen parameter u4 ¯ 3 m. Non-zero Y-K angle (αYK) values implies Y-K type magnetic ordering in the studied samples.
Magnetic Levitation Force Measurement System at Any Low Temperatures From 20 K To 300 K
NASA Astrophysics Data System (ADS)
Celik, Sukru; Guner, S. Baris; Coskun, Elvan
2015-03-01
Most of the magnetic levitation force measurements in previous studies were performed at liquid nitrogen temperatures. For the levitation force of MgB2 and iron based superconducting samples, magnetic levitation force measurement system is needed. In this study, magnetic levitation force measurement system was designed. In this system, beside vertical force versus vertical motion, lateral and vertical force versus lateral motion measurements, the vertical force versus temperature at the fixed distance between permanent magnet PM - superconducting sample SS and the vertical force versus time measurements were performed at any temperatures from 20 K to 300 K. Thanks to these measurements, the temperature dependence, time dependence, and the distance (magnetic field) and temperature dependences of SS can be investigated. On the other hand, the magnetic stiffness MS measurements can be performed in this system. Using the measurement of MS at different temperature in the range, MS dependence on temperature can be investigated. These measurements at any temperatures in the range help to the superconductivity properties to be characterized. This work was supported by TUBTAK-the Scientific and technological research council of Turkey under project of MFAG - 110T622. This system was applied to the Turkish patent institute with the Application Number of 2013/13638 on 22/11/2013.
NASA Astrophysics Data System (ADS)
Diop, L. V. B.; Kastil, J.; Isnard, O.; Arnold, Z.; Kamarad, J.
2014-10-01
The magnetism and transport properties were studied for Laves (Hf,Ta)Fe2 itinerant-electron compounds, which exhibit a temperature-induced first-order transition from the ferromagnetic (FM) to the antiferromagnetic (AFM) state upon heating. At finite temperatures, the field-induced metamagnetic phase transition between the AFM and FM has considerable effects on the transport properties of these model metamagnetic compounds. A large negative magnetoresistance of about 14% is observed in accordance with the metamagnetic transition. The magnetic phase diagram is determined for the Laves Hf1-xTaxFe2 series and its Ta concentration dependence discussed. An unusual behavior is revealed in the paramagnetic state of intermediate compositions, it gives rise to the rapid increase and saturation of the local spin fluctuations of the 3d electrons. This new result is analysed in the frame of the theory of Moriya. For a chosen composition Hf0.825Ta0.175Fe2, exhibiting such remarkable features, a detailed investigation is carried out under hydrostatic pressure up to 1 GPa in order to investigate the volume effect on the magnetic properties. With increasing pressure, the magnetic transition temperature TFM-AFM from ferromagnetic to antiferromagnetic order decreases strongly non-linearly and disappears at a critical pressure of 0.75 GPa. In the pressure-induced AFM state, the field-induced first-order AFM-FM transition appears and the complex temperature dependence of the AFM-FM transition field is explained by the contribution from both the magnetic and elastic energies caused by the significant temperature variation of the amplitude of the local Fe magnetic moment. The application of an external pressure leads also to the progressive decrease of the Néel temperature TN. In addition, a large pressure effect on the spontaneous magnetization MS for pressures below 0.45 GPa, dln(Ms)/dP = -6.3 × 10-2 GPa-1 was discovered. The presented results are consistent with Moriya's theoretical predictions and can significantly help to better understand the underlying physics of itinerant electron magnetic systems nowadays widely investigated for both fundamental and applications purposes.
First results on quiet and magnetic granulation from SOUP
NASA Technical Reports Server (NTRS)
Title, A. M.; Tarbell, T. D.; Acton, L.; Duncan, D.; Ferguson, S. H.; Finch, M.; Frank, Z.; Kelly, G.; Lindgren, R.; Morrill, M.
1987-01-01
The flight of Solar Optical Universal Polarimeter (SOUP) on Spacelab 2 allowed the collection of time sequences of diffraction limited (0.5 arc sec) granulation images with excellent pointing (0.003 arc sec) and completely free of the distortion that plagues groundbased images. The p-mode oscillations are clearly seen in the data. Using Fourier transforms in the temporal and spatial domain, it was shown that the p-modes dominate the autocorrelation lifetime in magnetic regions. When these oscillations are removed the autocorrelation lifetime is found to be 500 sec in quiet and 950 sec in magnetic regions. In quiet areas exploding granules are seen to be common. It is speculated that a significant fraction of granule lifetimes are terminated by nearby explosions. Using local correlation tracking techniques it was able to measure horizontal displacements, and thus transverse velocities, in the magnetic field. In quiet sun it is possible to detect both super and mesogranulation. Horizontal velocities are as great as 1000 m/s and the average velocity is 400 m/s. In magnetic regions horizontal velocities are much less, about 100 m/s.
First results on quiet and magnetic granulation from SOUP
NASA Astrophysics Data System (ADS)
Title, A. M.; Tarbell, T. D.; Acton, L.; Duncan, D.; Ferguson, S. H.; Finch, M.; Frank, Z.; Kelly, G.; Lindgren, R.; Morrill, M.
1987-09-01
The flight of Solar Optical Universal Polarimeter (SOUP) on Spacelab 2 allowed the collection of time sequences of diffraction limited (0.5 arc sec) granulation images with excellent pointing (0.003 arc sec) and completely free of the distortion that plagues groundbased images. The p-mode oscillations are clearly seen in the data. Using Fourier transforms in the temporal and spatial domain, it was shown that the p-modes dominate the autocorrelation lifetime in magnetic regions. When these oscillations are removed the autocorrelation lifetime is found to be 500 sec in quiet and 950 sec in magnetic regions. In quiet areas exploding granules are seen to be common. It is speculated that a significant fraction of granule lifetimes are terminated by nearby explosions. Using local correlation tracking techniques it was able to measure horizontal displacements, and thus transverse velocities, in the magnetic field. In quiet sun it is possible to detect both super and mesogranulation. Horizontal velocities are as great as 1000 m/s and the average velocity is 400 m/s. In magnetic regions horizontal velocities are much less, about 100 m/s.
Deep Zonal Flow and Time Variation of Jupiter’s Magnetic Field
NASA Astrophysics Data System (ADS)
Cao, Hao; Stevenson, David J.
2017-10-01
All four giant planets in the Solar System feature zonal flows on the order of 100 m/s in the cloud deck, and large-scale intrinsic magnetic fields on the order of 1 Gauss near the surface. The vertical structure of the zonal flows remains obscure. The end-member scenarios are shallow flows confined in the radiative atmosphere and deep flows throughout the entire planet. The electrical conductivity increases rapidly yet smoothly as a function of depth inside Jupiter and Saturn. Deep zonal flows will advect the non-axisymmetric component of the magnetic field, at depth with even modest electrical conductivity, and create time variations in the magnetic field.The observed time variations of the geomagnetic field has been used to derive surface flows of the Earth’s outer core. The same principle applies to Jupiter, however, the connection between the time variation of the magnetic field (dB/dt) and deep zonal flow (Uphi) at Jupiter is not well understood due to strong radial variation of electrical conductivity. Here we perform a quantitative analysis of the connection between dB/dt and Uphi for Jupiter adopting realistic interior electrical conductivity profile, taking the likely presence of alkali metals into account. This provides a tool to translate expected measurement of the time variation of Jupiter’s magnetic field to deep zonal flows. We show that the current upper limit on the dipole drift rate of Jupiter (3 degrees per 20 years) is compatible with 10 m/s zonal flows with < 500 km vertical scale height below 0.972 Rj. We further demonstrate that fast drift of resolved magnetic features (e.g. magnetic spots) at Jupiter is a possibility.
Evolution of structural and magnetic properties in La xCe 2-xCo 16 Ti for $$0 \\leq x \\leq 2$$
Conner, Benjamin S.; McGuire, Michael A.; Veedu, Shanavas Kavungal; ...
2016-11-11
Here we examine the intrinsic magnetic and structural properties of the title alloys, permanent magnet materials based on the abundant rare-earth elements lanthanum and cerium, since these properties (T C, M sH a(K 1, K 2)) will set the upper limits on the quality of permanent magnet that can be fabricated from said alloys. Ce 2Co 16Ti has a high magnetic anisotropy (H a = 65 kOe) but a relatively low saturation magnetization (M s = 7.3 kG), and La 2Co 16Ti has a high Ms(9.5 kG) but Ha too low for most applications (16 kOe). Though these two end-membersmore » have previously well-known properties, changing economic conditions have made re-examination of systems containing cerium and lanthanum necessary as the economic viability of rare earth mining becomes dependent on extraction of products beyond what is currently considered useful and profitable within the rare earth elements. We find that replacing some lanthanum with cerium in La 2Co 16Ti increases H a by a factor of more than two, while decreasing M s by less than 5%. The measured Ms indicate maximum possible energy products in excess of 20 MG·Oe in these materials, which have Curie temperatures near 600 °C. Real energy products are expected to be greatest near x = 1. In conclusion, these findings identify La xCe 2-xCo 16Ti as a promising system for development of so-called gap magnets that fill the energy product gap between expensive rare-earth magnets and current non-rare earth alternatives.« less
Magnetic Susceptibility Measurements as a Proxy for Hydrocarbon Biodegradation
NASA Astrophysics Data System (ADS)
Mewafy, F.; Atekwana, E. A.; Slater, L. D.; Werkema, D.; Revil, A.; Ntarlagiannis, D.; Skold, M.
2011-12-01
Magnetic susceptibility (MS) measurements have been commonly used in paleoclimate studies, as a proxy for environmental pollution such as heavy metal contamination, and for delineating zones of oil seeps related to hydrocarbon exploration. Few studies have assessed the use of MS measurements for mapping zones of oil pollution. In this study, we investigated the variation in magnetic susceptibility across a hydrocarbon contaminated site undergoing biodegradation. Our objective was to investigate if MS measurements could be used as a proxy indicator of intrinsic bioremediation linked to the activity of iron reducing bacteria. An improved understanding of the mechanisms generating geophysical signatures associated with microbial enzymatic activity could permit the development of geophysical imaging technologies for long-term, minimally invasive and sustainable monitoring of natural biodegradation at oil spill sites. We used a Bartington MS probe to measure MS data along fifteen boreholes within contaminated (both free phase and dissolved phase hydrocarbon plumes) and clean areas. Our results show the following: (1) an enhanced zone of MS straddling the water table at the contaminated locations, not observed at the clean locations; (2) MS values within the free product plume are higher compared to values within the dissolved product plume; (3) the MS values within the vadoze zone above the free product plume are higher compared to values within the dissolved product plume; 4) the zone of high MS is thicker within the free product plume compared to the dissolved product plume. We suggest that the zone of enhanced MS results from the precipitation of magnetite related to the oxidation of the hydrocarbons coupled to iron reduction. Our data documents a strong correlation between MS and hydrocarbon concentration. We conclude that recognition of these zones of enhanced magnetite formation allows for the application of MS measurements as a: (1) low cost, rapid monitoring tool for assessing the extent of hydrocarbon contamination and (2) proxy for the presence of intrinsic bioremediation due to the activity of iron reducing bacteria.
Whole-head SQUID system in a superconducting magnetic shield.
Ohta, H; Matsui, T; Uchikawa, Y
2004-11-30
We have constructed a mobile whole-head SQUID system in a superconducting magnetic shield - a cylinder of high Tc superconductor BSCCO of 65 cm in diameter and 160 cm in length. We compared the noise spectra of several SQUID sensors of SNS Josephson junctions in the superconducting magnetic shield with those of the same SQUID sensors in a magnetically shielded room of Permalloy. The SQUID sensors in the superconducting magnetic shield are more than 100 times more sensitive than those in a magnetically shielded room of Permalloy below 1 Hz. We tested the whole-head SQUID system in the superconducting magnetic shield observing somatosensory signals evoked by stimulating the median nerve in the right wrist of patients by current pulses. We present data of 64 and 128 traces versus the common time axis for comparison. Most sensory responses of human brains phase out near 250 ms. However monotonic rhythms still remain even at longer latencies than 250 ms. The nodes of these rhythm are very narrow even at these longer latencies just indicating low noise characteristics of the SQUID system at low-frequencies. The current dipoles at the secondary somatosensory area SII are evoked at longer latencies than 250 ms contributing to a higher-level brain function. The SQUID system in a superconducting magnetic shield will also have advantages when it is used as a DC MEG to study very slow activities and function of the brain.
Cerebrospinal fluid inflammatory markers in patients with multiple sclerosis: a pilot study.
Matejčíková, Z; Mareš, J; Přikrylová Vranová, H; Klosová, J; Sládková, V; Doláková, J; Zapletalová, J; Kaňovský, P
2015-02-01
Multiple sclerosis (MS) is an inflammatory demyelinating disease of the central nervous system. Autoimmune inflammation is common in the early stages of MS. This stage is followed by the neurodegenerative process. The result of these changes is axon and myelin breakdown. Although MS is according to McDonald's revised diagnostic criteria primarily a clinical diagnosis, paraclinical investigation methods are an important part in the diagnosis of MS. In common practice, magnetic resonance imaging of the brain and spinal cord, examination of cerebrospinal fluid (CSF) and examination of visual evoked potentials are used. There are an increasing number of studies dealing with biomarkers in CSF and their role in the diagnosis and treatment of MS. We hypothesized that the levels of some markers could be changed in MS in comparison with controls. We studied five inflammatory markers [interleukin-6 (IL-6), interleukin-8, interleukin-10 (IL-10), beta-2-microglobulin, orosomucoid]. CSF and serum levels of inflammatory markers were assessed in 38 patients with newly diagnosed MS meeting McDonald's revised diagnostic criteria and in 28 subjects as a control group (CG). Levels of beta-2-microglobulin and interleukin-8 in CSF were found to be significantly higher in MS patients in comparison to CG (p < 0.001 resp. p = 0.007). No differences in other CSF markers (IL-6, IL-10 and orosomucoid) and serum levels of all markers between both groups were found. The levels of two studied inflammatory markers were found to be increased at the time of first clinical symptoms of MS. Research on the role of inflammatory and neurodegenerative markers in MS should continue.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Goto, Tetsuya; Matsuoka, Takaaki; Ohmi, Tadahiro
Novel magnetron-sputtering equipment, called rotation magnet sputtering (ROT-MS), was developed to overcome various disadvantages of current magnetron-sputtering equipment. Disadvantages include (1) very low target utilization of less than 20%, (2) difficulty in obtaining uniform deposition on the substrate, and (3) charge-up damages and ion-bombardment-induced damages resulting from very high electron temperature (>3 eV) and that the substrate is set at the plasma excitation region. In ROT-MS, a number of moving high-density plasma loops are excited on the target surface by rotating helical magnets, resulting in very high target utilization with uniform target erosion and uniform deposition on the substrate. Thismore » excellent performance can be principally maintained even if equipment size increases for very large-substrate deposition. Because strong horizontal magnetic fields (>0.05 T) are produced within a very limited region just at the target surface, very low electron-temperature plasmas (<2.5 eV for Ar plasma and <1 eV for direct-current-excited Xe plasma) are excited at the very limited region adjacent to the target surface with a combination of grounded plate closely mounted on the strong magnetic field region. Consequently, the authors can establish charge-up damage-free and ion-bombardment-induced damage-free processes. ROT-MS has been applied for thin-film formation of LaB{sub 6}, which is well known as a stable, low-work-function bulk-crystal material for electron emissions. The work function of the LaB{sub 6} film decreased to 2.8 eV due to enhanced (100)-orientation crystallinity and reduced resistivity realized by adjusting the flux of low-energy bombarding ions impinging on the depositing surface, which work very efficiently, improving the performance of the electron emission devices.« less
Magnetic properties of cobalt ferrite synthesized by mechanical alloying
NASA Astrophysics Data System (ADS)
Dedi, Idayanti, Novrita; Kristiantoro, Tony; Alam, Ginanjar Fajar Nur; Sudrajat, Nanang
2018-05-01
Cobalt ferrite (CoFe2O4) is a well-known hard magnetic material with high coercivity and moderate magnetization. These properties, along with their great physical and chemical stability, make CoFe2O4 suitable for many applications such as generator, audio, video-tape etc. In this study, the magnetic properties of cobalt ferrite synthesized via the mechanical alloying using α-Fe2O3 of Hot Strip Mill (HSM) waste and cobalt carbonate as the precursors have been investigated. Structural and magnetic properties were systematically investigated. The X-ray diffraction (XRD) pattern exhibited the single phase of cobalt ferrite when the sintering temperature was 1000 °C. Permagraph measurements of the sintered sample revealed a saturation magnetization (Ms) of 77-83 emu/g and coercivity (Hc) of 575 Oe which closely to the magnetic properties of references; Ms = 47.2-56.7 emu/g and Hc =233-2002 Oe.
Development of fast cooling pulsed magnets at the Wuhan National High Magnetic Field Center.
Peng, Tao; Sun, Quqin; Zhao, Jianlong; Jiang, Fan; Li, Liang; Xu, Qiang; Herlach, Fritz
2013-12-01
Pulsed magnets with fast cooling channels have been developed at the Wuhan National High Magnetic Field Center. Between the inner and outer sections of a coil wound with a continuous length of CuNb wire, G10 rods with cross section 4 mm × 5 mm were inserted as spacers around the entire circumference, parallel to the coil axis. The free space between adjacent rods is 6 mm. The liquid nitrogen flows freely in the channels between these rods, and in the direction perpendicular to the rods through grooves provided in the rods. For a typical 60 T pulsed magnetic field with pulse duration of 40 ms, the cooling time between subsequent pulses is reduced from 160 min to 35 min. Subsequently, the same technology was applied to a 50 T magnet with 300 ms pulse duration. The cooling time of this magnet was reduced from 480 min to 65 min.
Defining active progressive multiple sclerosis.
Sellebjerg, Finn; Börnsen, Lars; Ammitzbøll, Cecilie; Nielsen, Jørgen Erik; Vinther-Jensen, Tua; Hjermind, Lena Elisabeth; von Essen, Marina; Ratzer, Rikke Lenhard; Soelberg Sørensen, Per; Romme Christensen, Jeppe
2017-11-01
It is unknown whether disease activity according to consensus criteria (magnetic resonance imaging activity or clinical relapses) associate with cerebrospinal fluid (CSF) changes in progressive multiple sclerosis (MS). To compare CSF biomarkers in active and inactive progressive MS according to consensus criteria. Neurofilament light chain (NFL), myelin basic protein (MBP), IgG-index, chitinase-3-like-1 (CHI3L1), matrix metalloproteinase-9 (MMP-9), chemokine CXCL13, terminal complement complex, leukocyte counts and nitric oxide metabolites were measured in primary ( n = 26) and secondary progressive MS ( n = 26) and healthy controls ( n = 24). Progressive MS patients had higher CSF cell counts, IgG-index, CHI3L1, MMP-9, CXCL13, NFL and MBP concentrations. Active patients were younger and had higher NFL, CXCL13 and MMP-9 concentrations than inactive patients. Patients with active disease according to consensus criteria or detectable CXCL13 or MMP-9 in CSF were defined as having combined active progressive MS. These patients had increased CSF cell counts, IgG-index and MBP, NFL and CHI3L1 concentrations. Combined inactive patients only had increased IgG-index and MBP concentrations. Patients with combined active progressive MS show evidence of inflammation, demyelination and neuronal/axonal damage, whereas the remaining patients mainly show evidence of active demyelination. This challenges the idea that neurodegeneration independent of inflammation is crucial in disease progression.
Infection risk in patients on multiple sclerosis therapeutics.
Williamson, Eric M; Berger, Joseph R
2015-03-01
The interface of multiple sclerosis (MS) and infection occurs on several levels. First, infectious disease has been postulated as a potential trigger, if not cause, of MS. Second, exacerbation of MS has been well-documented as a consequence of infection, and, lastly, infectious diseases have been recognized as a complication of the therapies currently employed in the treatment of MS. MS is a disease in which immune dysregulation is a key component. Examination of central nervous system (CNS) tissue of people affected by MS demonstrates immune cell infiltration, activation and inflammation. Therapies that alter the immune response have demonstrated efficacy in reducing relapse rates and evidence of brain inflammation on magnetic resonance imaging (MRI). Despite the altered immune response in MS, there is a lack of evidence that these patients are at increased risk of infectious disease in the absence of treatment or debility. Links between infections and disease-modifying therapies (DMTs) used in MS will be discussed in this review, as well as estimates of occurrence and ways to potentially minimize these risks. We address infection in MS in a comprehensive fashion, including (1) the impact of infections on relapse rates in patients with MS; (2) a review of available infection data from pivotal trials and postmarketing studies for the approved and experimental DMTs, including frequency, types and severity of infections; and (3) relevant risk minimization strategies, particularly as they pertain to progressive multifocal leukoencephalopathy (PML).
Belogurov, Alexey; Zakharov, Konstantin; Lomakin, Yakov; Surkov, Kirill; Avtushenko, Sergey; Kruglyakov, Peter; Smirnov, Ivan; Makshakov, Gleb; Lockshin, Curtis; Gregoriadis, Gregory; Genkin, Dmitry; Gabibov, Alexander; Evdoshenko, Evgeniy
2016-10-01
Previously, we showed that CD206-targeted liposomal delivery of co-encapsulated immunodominant myelin basic protein (MBP) sequences MBP 46-62 , MBP 124-139 and MBP 147-170 (Xemys) suppressed experimental autoimmune encephalomyelitis in dark Agouti rats. The objective of this study was to assess the safety of Xemys in the treatment of patients with relapsing-remitting multiple sclerosis (MS) and secondary progressive MS, who failed to achieve a sustained response to first-line disease-modifying therapies. In this phase I, open-label, dose-escalating, proof-of-concept study, 20 patients with relapsing-remitting or secondary progressive MS received weekly subcutaneously injections with ascending doses of Xemys up to a total dose of 2.675 mg. Clinical examinations, including Expanded Disability Status Scale score, magnetic resonance imaging results, and serum cytokine concentrations, were assessed before the first injection and for up to 17 weeks after the final injection. Xemys was safe and well tolerated when administered for 6 weeks to a maximum single dose of 900 μg. Expanded Disability Status Scale scores and numbers of T2-weighted and new gadolinium-enhancing lesions on magnetic resonance imaging were statistically unchanged at study exit compared with baseline; nonetheless, the increase of number of active gadolinium-enhancing lesions on weeks 7 and 10 in comparison with baseline was statistically significant. During treatment, the serum concentrations of the cytokines monocyte chemoattractant protein-1, macrophage inflammatory protein-1β, and interleukin-7 decreased, whereas the level of tumor necrosis factor-α increased. These results provide evidence for the further development of Xemys as an antigen-specific, disease-modifying therapy for patients with MS.
Structural, magnetic and Mossbauer studies of TI doped Gd2Fe17-xTix and Gd2Fe16Ga1-xTix (0≤x≤1)
NASA Astrophysics Data System (ADS)
Pokharel, G.; Syed Ali, K. S.; Mishra, S. R.
2015-05-01
Magnetic compounds of the type Gd2Fe17-xTix and Gd2Fe16Ga1-xTix (x=0.0-1.0) were prepared by arc melting and their structural and magnetic properties were studied by X-ray diffraction (XRD), magnetometery and Mossbauer spectroscopy. The Rietveld analysis of X-ray data shows that these α-Fe free solid-solutions crystallize with Th2Ni17-type structure as main phase along with GdFe2 and TiFe2 as additional phases at higher, x≥0.5 contents. The unit cell volume expands with Ga and Ti content. The Rietveld analysis indicate that both Ti and Ga atoms prefer 12j and 12k sites in both compounds. The effect of Ti and co-substituted Ga-Ti on the bond length are quite different. The saturation magnetization Ms, at 300 K for Gd2Fe17-xTix and Gd2Fe16Ga1-xTix was found to decrease linearly with increasing Ti content. The Ms in both compounds at x=1 reduced by 9% as compared to their parent compounds at x=0. The Curie temperature, Tc, for Gd2Fe17-xTix increased from 513 K (x=0) to 544 K (x=1) while Tc for Gd2Fe16Ga1-xTix reduced from 560 (x=0) to 544 K (x=1) with increase in Ti content. Thus the observed variation in Tc follows Gd2Fe17
NASA Astrophysics Data System (ADS)
Hassen, Harzali; Adel, Megriche; Arbi, Mgaidi
2018-03-01
Ultrasound-assisted co-precipitation has been used to prepare nano-sized Ni0.4Cu0.2Zn0.4Fe2O4 ferrite. Continuous (C-US) and pulsed (P-US) ultrasound modes are used at constant frequency = 20 kHz, reaction time = 2 h and pulse durations of 10 s on and 10 s off. All experiments were conducted at two temperatures 90 and 100°C. Samples were characterized by X-ray diffraction (XRD), Fourier transform spectroscopy (FT-IR), N2 adsorption isotherms at 77 k analysis (BET), transmission electron microscopy (TEM) and vibrating sample magnetometry (VSM) techniques. A nanocrystalline single-phase with particle size in the range 12-18 nm is obtained in both modes: continuous and pulsed ultrasound mode. FT-IR measurements show two absorption bands assigned to the tetrahedral and octahedral vibrations (ν1 and ν2) characteristics of cubic spinel ferrite. The specific surface area (S BET) is in the range of 110-140 m2 g-1 and an average pore size between 5.5 and 6.5 nm. The lowest values are obtained in pulsed mode. Finally, this work shows that the magnetic properties are affected by the ultrasound conditions, without affecting the particle shape. The saturation magnetization (Ms) values obtained for all samples are comparable. In P-US mode, the saturation magnetization (Ms) increases as temperature increases. Moreover, P-US mode opens a new avenue for synthesis of NiCuZn ferrites.
NASA Astrophysics Data System (ADS)
Belmeguenai, M.; Gabor, M. S.; Roussigné, Y.; Petrisor, T.; Mos, R. B.; Stashkevich, A.; Chérif, S. M.; Tiusan, C.
2018-02-01
C o2FeAl (CFA) ultrathin films, of various thicknesses (0.9 nm ≤tCFA≤1.8 nm ), have been grown by sputtering on Si substrates, using Ir as a buffer layer. The magnetic properties of these structures have been studied by vibrating sample magnetometry (VSM), miscrostrip ferromagnetic resonance (MS-FMR), and Brillouin light scattering (BLS) in the Damon-Eshbach geometry. VSM characterizations show that films are mostly in-plane magnetized and the saturating field perpendicular to the film plane increases with decreasing CFA thickness suggesting the existence of a perpendicular interface anisotropy. The presence of a magnetic dead layer of 0.44 nm has been detected by VSM. The MS-FMR with the magnetic field applied perpendicularly to the film plane has been used to determine the gyromagnetic factor. The BLS measurements reveal a pronounced nonreciprocal spin wave propagation, due to the interfacial Dzyaloshinskii-Moriya interaction (DMI) induced by the Ir interface with CFA, which increases with decreasing CFA thickness. The DMI sign has been found to be the same (negative) as that of Pt/Co, in contrast to the ab initio calculation on Ir/Co, where it is found to be positive. The thickness dependence of the effective DMI constant shows the existence of two regimes similarly to that of the perpendicular anisotropy constant. The surface DMI constant Ds was estimated to be -0.37 pJ /m for the thickest samples, where a linear thickness dependence of the effective DMI constant has been observed.
Mougin, Olivier; Abdel-Fahim, Rasha; Dineen, Robert; Pitiot, Alain; Evangelou, Nikos; Gowland, Penny
2016-11-01
To present an improved three-dimensional (3D) interleaved phase sensitive inversion recovery (PSIR) sequence including a concomitantly acquired new contrast, null point imaging (NPI), to help detect and classify abnormalities in cortical gray matter. The 3D gradient echo PSIR images were acquired at 0.6 mm isotropic resolution on 11 multiple sclerosis (MS) patients and 9 controls subjects using a 7 Tesla (T) MRI scanner, and 2 MS patients at 3T. Cortical abnormalities were delineated on the NPI/PSIR data and later classified according to position in the cortex. The NPI helped detect cortical lesions within the cortical ribbon with increased, positive contrast compared with the PSIR. It also provided improved intrinsic delineation of the ribbon, increasing confidence in classifying the lesions' locations. The proposed PSIR facilitates the classification of cortical lesions by providing two T 1 -weighted 3D datasets with isotropic resolution, including the NPI showing cortical lesions with clear delineation of the gray/white matter boundary and minimal partial volume effects. Magn Reson Med 76:1512-1516, 2016. © 2015 The Authors. Magnetic Resonance in Medicine published by Wiley Periodicals, Inc. on behalf of International Society for Magnetic Resonance in Medicine. This is an open access article under the terms of the Creative Commons Attribution License, which permits use, distribution and reproduction in any medium, provided the original work is properly cited. © 2015 The Authors. Magnetic Resonance in Medicine published by Wiley Periodicals, Inc. on behalf of International Society for Magnetic Resonance in Medicine.
NASA Astrophysics Data System (ADS)
Kishore, G. V. K.; Kumar, Anish; Rajkumar, K. V.; Purnachandra Rao, B.; Pramanik, Debabrata; Kapoor, Komal; Jha, Sanjay Kumar
2017-12-01
The paper presents a new methodology for detection and evaluation of mild steel (MS) can material embedded into oxide dispersion strengthened (ODS) steel tubes by magnetic Barkhausen emission (MBE) technique. The high frequency MBE measurements (125 Hz sweep frequency and 70-200 kHz analyzing frequency) are found to be very sensitive for detection of presence of MS on the surface of the ODS steel tube. However, due to a shallow depth of information from the high frequency MBE measurements, it cannot be used for evaluation of the thickness of the embedded MS. The low frequency MBE measurements (0.5 Hz sweep frequency and 2-20 kHz analyzing frequency) indicate presence of two MBE RMS voltage peaks corresponding to the MS and the ODS steel. The ratio of the two peaks changes with the thickness of the MS and hence, can be used for measurement of the thickness of the MS layer.
Measurements of Hk and Ms in thin magnetic films by the angular dependence of the planar Hall effect
NASA Astrophysics Data System (ADS)
Vatskicheva, M.; Vatskichev, L.
1987-11-01
It is shown that the angular dependences of the planar Hall effect measured with infinite magnetic field and with magnetic field H⩾ Hk have an intersection point and this fact is enough for measuring the anisotropy field Hk applying the method presented by Pastor, Ferreiro and Torres in J. Magn. Magn. Mat. 53 (1986) 349, 62 (1986) 101. The scaling of the Hall tension U proportional to M2s in mV/Am -1 gives a possibility for calculating the Ms-values of the films. These assumptions are verified for NiFe- and NiFeGe films with a uniaxial magnetic anisotropy.
Magnetic susceptibility as a proxy for investigating microbially mediated iron reduction
Mewafy, F.M.; Atekwana, E.A.; Werkema, D.D.; Slater, L.D.; Ntarlagiannis, D.; Revil, A.; Skold, M.; Delin, G.N.
2011-01-01
We investigated magnetic susceptibility (MS) variations in hydrocarbon contaminated sediments. Our objective was to determine if MS can be used as an intrinsic bioremediation indicator due to the activity of iron-reducing bacteria. A contaminated and an uncontaminated core were retrieved from a site contaminated with crude oil near Bemidji, Minnesota and subsampled for MS measurements. The contaminated core revealed enriched MS zones within the hydrocarbon smear zone, which is related to iron-reduction coupled to oxidation of hydrocarbon compounds and the vadose zone, which is coincident with a zone of methane depletion suggesting aerobic or anaerobic oxidation of methane is coupled to iron-reduction. The latter has significant implications for methane cycling. We conclude that MS can serve as a proxy for intrinsic bioremediation due to the activity of iron-reducing bacteria iron-reducing bacteria and for the application of geophysics to iron cycling studies. ?? 2011 by the American Geophysical Union.
Earthquakes in the Mantle? Insights from Ultramafic Pseudotachylytes
NASA Astrophysics Data System (ADS)
Meado, A.; Ferre, E. C.; Ueda, T.; Ashwal, L. D.; Deseta, N.
2015-12-01
Deep earthquakes in subduction/collision zones may originate from mechanical failure of ultramafic rocks at mantle depths. Fault pseudotachylytes in peridotites have been attributed to seismic slip at depths >30 km. However, the possibility of frictional melting at shallower depths still exist. While pristine mantle rocks typically lack magnetite, postseismic serpentinization would likely involve formation of abundant multi-domain (MD) magnetite. Single-domain (SD) to pseudo-single domain (PSD) magnetite may also form in pseudotachylytes through breakdown of mafic silicates. Magnetite has a large magnetic susceptibility (Km). MD magnetite shows low magnetic remanence / magnetic saturation ratios (Mr/Ms) compared to SD-PSD magnetite. The formation of coseismic magnetite however would depend on fO2. Hence, in unserpentinized ultramafic pseudotachylytes, magnetite would form preferentially under shallow, high fO2 conditions. Coseismically deformed magnetite would result in a high anisotropy of magnetic susceptibility (AMS). Here, we present a predictive model of the magnetic properties and magnetic fabrics of ultramafic pseudotachylytes formed under four conditions: i) deep seismic slip and no syn- or postseismic serpentinization: low Km (<600 . 10^-6 [SI]), low Mr/Ms (<0.1), and low AMS (<1.1) ii) deep seismic slip followed by static serpentinization: high Km (>3,000 . 10^-6 [SI]), low Mr/Ms (<0.1), low AMS (<1.1) iii) deep or shallow seismic slip in previously serpentinized peridotites: high Km (>3,000 . 10^-6 [SI]), moderate Mr/Ms (0.1-0.5), high AMS (>1.5) iv) shallow seismic slip with no serpentinization: moderate Km (600-3,000 . 10^-6 [SI]), high Mr/Ms (>0.5), moderate AMS (1.1-1.5) We test these models using samples from the Balmuccia Massif (Italy) and the Schistes Lustrés (Corsica). These models may provide new constrains for ultramafic pseudotachylytes regarding their depth of formation and the timing of serpentinization.
Bonnier, Guillaume; Maréchal, Benedicte; Fartaria, Mário João; Falkowskiy, Pavel; Marques, José P; Simioni, Samanta; Schluep, Myriam; Du Pasquier, Renaud; Thiran, Jean-Philippe; Krueger, Gunnar; Granziera, Cristina
2017-01-01
Quantitative and semi-quantitative MRI (qMRI) metrics provide complementary specificity and differential sensitivity to pathological brain changes compatible with brain inflammation, degeneration, and repair. Moreover, advanced magnetic resonance imaging (MRI) metrics with overlapping elements amplify the true tissue-related information and limit measurement noise. In this work, we combined multiple advanced MRI parameters to assess focal and diffuse brain changes over 2 years in a group of early-stage relapsing-remitting MS patients. Thirty relapsing-remitting MS patients with less than 5 years disease duration and nine healthy subjects underwent 3T MRI at baseline and after 2 years including T1, T2, T2* relaxometry, and magnetization transfer imaging. To assess longitudinal changes in normal-appearing (NA) tissue and lesions, we used analyses of variance and Bonferroni correction for multiple comparisons. Multivariate linear regression was used to assess the correlation between clinical outcome and multiparametric MRI changes in lesions and NA tissue. In patients, we measured a significant longitudinal decrease of mean T2 relaxation times in NA white matter ( p = 0.005) and a decrease of T1 relaxation times in the pallidum ( p < 0.05), which are compatible with edema reabsorption and/or iron deposition. No longitudinal changes in qMRI metrics were observed in controls. In MS lesions, we measured a decrease in T1 relaxation time ( p -value < 2.2e-16) and a significant increase in MTR ( p -value < 1e-6), suggesting repair mechanisms, such as remyelination, increased axonal density, and/or a gliosis. Last, the evolution of advanced MRI metrics-and not changes in lesions or brain volume-were correlated to motor and cognitive tests scores evolution (Adj- R 2 > 0.4, p < 0.05). In summary, the combination of multiple advanced MRI provided evidence of changes compatible with focal and diffuse brain repair at early MS stages as suggested by histopathological studies.
Yao, Ning; Chen, Hemei; Lin, Huaqing; Deng, Chunhui; Zhang, Xiangmin
2008-03-21
Human serum contains a complex array of proteolytically derived peptides (serum peptidome), which contain biomarkers of preclinical screening and disease diagnosis. Recently, commercial C(8)-functionalized magnetic beads (1-10 microm) were widely applied to the separation and enrichment of peptides in human serum, prior to matrix-assisted laser desorption/ionization time-of-flight mass spectrometry (MALDI-TOF-MS) analysis. In this work, laboratory-prepared C(8)-functionalized magnetic nanoparticles (about 50 nm) were prepared and applied to the fast separation and the enrichment of peptides from serum. At first, the C(8)-magnetic nanoparticles were synthesized by modifying amine-functionalized magnetic nanoparticles with chlorodimethyloctylsilane. These synthesized C(8)-amine-functionalized magnetic particles have excellent magnetic responsibility, high dispersibility and large surface area. Finally, the C(8)-magnetic nanoparticles were successfully applied to fast and efficient enrichment of low-abundance peptides from protein tryptic digestion and human serum followed by MALDI-TOF-MS analysis.
NASA Astrophysics Data System (ADS)
Harikrishnan, V.; Vizhi, R. Ezhil; Rajan Babu, D.; Saravanan, P.
2018-02-01
The effect of conventional and spark plasma sintering processes on the structural and magnetic properties of Ba0.5Sr0.5Fe12-2xCox(MgZn)x/2O19 (x = 0.2, 0.4 and 0.6) was investigated in this study. XRD patterns of both conventionally sintered (CS) and spark plasma sintered (SPS) samples with x = 0.2 and 0.4 showed the crystallization of Ba0.5Sr0.5Fe12O19-phase with space group of P63/mmc. However, in the case of SPS sample with x = 0.4, a secondary peak of α-Fe2O3 was observed. SEM analysis on the SPS samples revealed dense morphology with low porosity; while the CS samples showed the presence of aggregated particles with spherical shapes. Maximum values of saturation magnetization, MS (58 emu/g) and coercivity, HC (3.5 kOe) were obtained for the CS samples with x = 0.4; while their SPS counterparts revealed increased MS (65 emu/g) and HC (3.9 kOe) values. The observed magnetization reversal behaviour for both sintering conditions were not smooth in the case of x = 0.2, which indicated the existence of two-phase behavior. The temperature dependent magnetization studies for x = 0.2 and 0.4 were performed in order to analyze the variation in Curie temperature against Co-Mg-Zn substitution and the obtained results are discussed on the basis of crystallization of hexaferrite-phase.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Rane, R., E-mail: ramu@ipr.res.in; Ranjan, M.; Mukherjee, S.
2016-01-15
The combined effect of magnetic field (B), gas pressure (P), and the corresponding discharge voltage on the discharge properties of argon in inverted cylindrical magnetron has been investigated. In the experiment, anode is biased with continuous 10 ms sinusoidal half wave. It is observed that at a comparatively higher magnetic field (i.e., >200 gauss) and lower operating pressure (i.e., <1 × 10{sup −3} mbar), the discharge extinguishes and demands a high voltage to reignite. Discharge current increases with increase in magnetic field and starts reducing at sufficiently higher magnetic field for a particular discharge voltage due to restricted electron diffusion towards the anode.more » It is observed that B/P ratio plays an important role in sustaining the discharge and is constant for a discharge voltage. The discharge is transformed to negative space charge regime from positive space charge regime at certain B/P ratio and this ratio varies linearly with the discharge voltage. The space charge reversal is indicated by the radial profile of the floating potential and plasma potential in between two electrodes for different magnetic fields. At a particular higher magnetic field (beyond 100 gauss), the floating potential increases gradually with the radial distance from cathode, whereas it remains almost constant at lower magnetic field.« less
Kretzschmar, M; Heilmeier, U; Yu, A; Joseph, G B; Liu, F; Solka, M; McCulloch, C E; Nevitt, M C; Link, T M
2016-08-01
To investigate the change in cartilage T2 values and structural degeneration in knee joints over 72 months in women of African American (AA) vs Caucasian American (CA) ethnicity. Knee 3T magnetic resonance imaging (MRIs) from baseline, 24, 48 and 72 months visits of 100 AA and 100 CA women from the Osteoarthritis Initiative (OAI) were assessed for cartilage T2 values and whole-organ magnetic resonance imaging (WORMS) score. Subjects were pair-matched by age, body mass index (BMI), Kellgren-Lawrence (KL) score, clinical site and subcohort within the OAI. We compared the rate of change in whole knee cartilage T2 values and WORMS cartilage, bone marrow edema pattern (BMEP) and meniscus scores between the two ethnic groups using mixed random effects models. At 24 and 48 months 60 subjects and at 72 months 45 subjects per group were available for analysis resulting in 38 complete pairs with data of all time points. Compared to CA, cartilage T2 values in AA increased at a significantly faster rate at baseline (AA: 0.45 ms/y, CA: 0.35 ms/y, P = 0.029) and averaged over 6 years (AA: 0.36 ms/y, CA: 0.27 ms/y, P = 0.039) with changes in both groups reaching a plateau by 48 months. Cartilage, meniscus and BMEP scores tended to increase in both groups during follow up, but rates of change did not differ by ethnicity. Cartilage T2 values increased faster over 72 months in AA than CA, however changes in WORMS cartilage, meniscus and BMEP scores did not differ. T2 values may be able to distinguish ethnicity-related differences of cartilage degeneration at an early stage before differences in structural joint degeneration appear. Copyright © 2016 Osteoarthritis Research Society International. Published by Elsevier Ltd. All rights reserved.
NASA Astrophysics Data System (ADS)
Zhang, Yajing; Zhu, Yuan; Wang, Kangjun; Li, Da; Wang, Dongping; Ding, Fu; Meng, Dan; Wang, Xiaolei; Choi, Chuljin; Zhang, Zhidong
2018-06-01
Cobalt carbides (Co2C and Co3C) nanocomposites exhibit interesting hard magnetic property, controlled synthesis of individual phase facilitates to clarify the magnetism of each, but it is difficult to obtain the single phase. We present a new approach to address this issue via a polyol refluxing process, using cobalt laurate as the precursor. The single phase Co2C magnetic nanochains self-assembled by nanoparticles are synthesized. The precursor is the key factor for controlling the growth kinetics of the Co2C nanochains. Cobalt, instead of cobalt carbides, is produced if cobalt chloride, acetate and acetylacetonate replace cobalt laurate as the precursor, respectively. The evolution of the growth process has been studied. In the formation of Co2C, first fcc-Co produces, then it transforms into Co2C by carbon diffusion process, and the produced carbon first exists in disordered state and then a small amount of them transforms into graphite. Saturation magnetization (Ms) of Co2C nanochains obtained at 300 °C for 20, 60, and 180 min are 27.1, 18.9, and 10.9 emu g-1, respectively. The decrease of Ms caused by increasing carbon content, and the carbon content are much larger than the stoichiometric ratio value of Co2C (9.2 wt%). The Co2C nanochains have mesoporous pore of 3.8 nm and the specific surface area of 48.6 m2 g-1.
NASA Astrophysics Data System (ADS)
Iramina, Keiji; Ge, Sheng; Hyodo, Akira; Hayami, Takehito; Ueno, Shoogo
2009-04-01
In this study, we applied a transcranial magnetic stimulation (TMS) to investigate the temporal aspect for the functional processing of visual attention. Although it has been known that right posterior parietal cortex (PPC) in the brain has a role in certain visual search tasks, there is little knowledge about the temporal aspect of this area. Three visual search tasks that have different difficulties of task execution individually were carried out. These three visual search tasks are the "easy feature task," the "hard feature task," and the "conjunction task." To investigate the temporal aspect of the PPC involved in the visual search, we applied various stimulus onset asynchronies (SOAs) and measured the reaction time of the visual search. The magnetic stimulation was applied on the right PPC or the left PPC by the figure-eight coil. The results show that the reaction times of the hard feature task are longer than those of the easy feature task. When SOA=150 ms, compared with no-TMS condition, there was a significant increase in target-present reaction time when TMS pulses were applied. We considered that the right PPC was involved in the visual search at about SOA=150 ms after visual stimulus presentation. The magnetic stimulation to the right PPC disturbed the processing of the visual search. However, the magnetic stimulation to the left PPC gives no effect on the processing of the visual search.
Roussis, S G
2001-08-01
The automated acquisition of the product ion spectra of all precursor ions in a selected mass range by using a magnetic sector/orthogonal acceleration time-of-flight (oa-TOF) tandem mass spectrometer for the characterization of complex petroleum mixtures is reported. Product ion spectra are obtained by rapid oa-TOF data acquisition and simultaneous scanning of the magnet. An analog signal generator is used for the scanning of the magnet. Slow magnet scanning rates permit the accurate profiling of precursor ion peaks and the acquisition of product ion spectra for all isobaric ion species. The ability of the instrument to perform both high- and low-energy collisional activation experiments provides access to a large number of dissociation pathways useful for the characterization of precursor ions. Examples are given that illustrate the capability of the method for the characterization of representative petroleum mixtures. The structural information obtained by the automated MS/MS experiment is used in combination with high-resolution accurate mass measurement results to characterize unknown components in a polar extract of a refinery product. The exhaustive mapping of all precursor ions in representative naphtha and middle-distillate fractions is presented. Sets of isobaric ion species are separated and their structures are identified by interpretation from first principles or by comparison with standard 70-eV EI libraries of spectra. The utility of the method increases with the complexity of the samples.
Influence of La-Mn substitutions on magnetic properties of M-type strontium hexaferrites
NASA Astrophysics Data System (ADS)
Zi, Z. F.; Ma, X. H.; Wei, Y. Y.; Liu, Q. C.; Zhang, M.; Zhu, X. B.; Sun, Y. P.
2018-05-01
M-type strontium hexaferrites of Sr1-xLaxFe12-xMnxO19 (0.0≤x≤0.4) were synthesized by the chemical coprecipitation method. X-ray diffraction (XRD) studies indicate that the samples are single-phase with the space group of P63/mmc. The results of field-emission scanning electronic microscopy (FE-SEM) show that the grains are regular hexagonal platelets with sizes from 0.7 to 1.4 μm. It is observed that the value of Hc increases at low substitution (x ≤ 0.1), reaches a maximum at x = 0.1 and then decreases at x ≥ 0.1, while the value of Ms decreases monotonously with increasing x. The variations of magnetic properties can be tentatively attributed to the effects of La-Mn substitutions. The results above indicate that our samples might be promising candidates for permanent magnets in the future.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Keating, Kristina; Slater, Lee; Ntarlagiannis, Dimitris
2015-02-24
This documents contains the final report for the project "Integrated Geophysical Measurements for Bioremediation Monitoring: Combining Spectral Induced Polarization, Nuclear Magnetic Resonance and Magnetic Methods" (DE-SC0007049) Executive Summary: Our research aimed to develop borehole measurement techniques capable of monitoring subsurface processes, such as changes in pore geometry and iron/sulfur geochemistry, associated with remediation of heavy metals and radionuclides. Previous work has demonstrated that geophysical method spectral induced polarization (SIP) can be used to assess subsurface contaminant remediation; however, SIP signals can be generated from multiple sources limiting their interpretation value. Integrating multiple geophysical methods, such as nuclear magnetic resonance (NMR)more » and magnetic susceptibility (MS), with SIP, could reduce the ambiguity of interpretation that might result from a single method. Our research efforts entails combining measurements from these methods, each sensitive to different mineral forms and/or mineral-fluid interfaces, providing better constraints on changes in subsurface biogeochemical processes and pore geometries significantly improving our understanding of processes impacting contaminant remediation. The Rifle Integrated Field Research Challenge (IFRC) site was used as a test location for our measurements. The Rifle IFRC site is located at a former uranium ore-processing facility in Rifle, Colorado. Leachate from spent mill tailings has resulted in residual uranium contamination of both groundwater and sediments within the local aquifer. Studies at the site include an ongoing acetate amendment strategy, native microbial populations are stimulated by introduction of carbon intended to alter redox conditions and immobilize uranium. To test the geophysical methods in the field, NMR and MS logging measurements were collected before, during, and after acetate amendment. Next, laboratory NMR, MS, and SIP measurements were collected on columns of Rifle sediments during acetate amendment. The laboratory experiments were designed to simulate the field experiments; changes in geophysical signals were expected to correlate with changes in redox conditions and iron speciation. Field MS logging measurements revealed vertically stratified magnetic mineralization, likely the result of detrital magnetic fraction within the bulk alluvium. Little to no change was observed in the MS data suggesting negligible production of magnetic phases (e.g. magnetite, pyrrhotite) as a result of sulfidogenesis. Borehole NMR measurements contained high levels of noise contamination requiring significant signal processing, and analysis suggests that any changes may be difficult to differentiate from simultaneous changes in water content. Laboratory MS and NMR measurements remained relatively stable throughout the course of the acetate amendment experiment, consistent with field measurements. However, SIP measurements changed during the acetate amendment associated with the formation of iron-sulfide mineral phases; a finding that is consistent with chemical analysis of the solid phase materials in the columns.« less
NASA Astrophysics Data System (ADS)
Li, G.; Hauser, N.; Jagadish, C.; Antoszewski, J.; Xu, W.
1996-06-01
Si δ-doped GaAs grown by metal organic vapor phase epitaxy (MOVPE) is characterized using magnetotransport measurements in tilted magnetic fields. Angular dependence of the longitudinal magnetoresistance (Rxx) vs the magnetic field (B) traces in tilted magnetic fields is used to examine the existence of a quasi-two-dimensional electron gas. The subband electron densities (ni) are obtained applying fast Fourier transform (FFT) analysis to the Rxx vs B trace and using mobility spectrum (MS) analysis of the magnetic field dependent Hall data. Our results show that (1) the subband electron densities remain roughly constant when the tilted magnetic field with an angle <30° measured from the Si δ-doped plane normal is ramped up to 13 T; (2) FFT analysis of the Rxx vs B trace and MS analysis of the magnetic field dependent Hall data both give the comparable results on subband electron densities of Si δ-doped GaAs with low δ-doping concentration, however, for Si δ-doped GaAs with very high δ-doping concentration, the occupation of the lowest subbands cannot be well resolved in the MS analysis; (3) the highest subband electron mobility reported to date of 45 282 cm2/s V is observed in Si δ-doped GaAs at 77 K in the dark; and (4) the subband electron densities of Si δ-doped GaAs grown by MOVPE at 700 °C are comparable to those grown by MBE at temperatures below 600 °C. A detailed study of magnetotransport properties of Si δ-doped GaAs in the parallel magnetic fields is then carried out to further confirm the subband electronic structures revealed by FFT and MS analysis. Our results are compared to theoretical calculation previously reported in literature. In addition, influence of different cap layer structures on subband electronic structures of Si δ-doped GaAs is observed and also discussed.
Viñas, Pilar; Pastor-Belda, Marta; Torres, Aitor; Campillo, Natalia; Hernández-Córdoba, Manuel
2016-05-01
Magnetic nanoparticles of cobalt ferrite with oleic acid as the surfactant (CoFe2O4/oleic acid) were used as sorbent material for the determination of alkylphenols in fruit juices. High sensitivity and specificity were achieved by liquid chromatography and detection using both diode-array (DAD) and electrospray-ion trap-tandem mass spectrometry (ESI-IT-MS/MS) in the selected reaction monitoring (SRM) mode of the negative fragment ions for alkylphenols (APs) and in positive mode for ethoxylate APs (APEOs). The optimized conditions for the different variables influencing the magnetic separation procedure were: mass of magnetic nanoparticles, 50mg, juice volume, 10mL diluted to 25mL with water, pH 6, stirring for 10min at room temperature, separation with an external neodymium magnet, desorption with 3mL of methanol and orbital shaking for 5min. The enriched organic phase was evaporated and reconstituted with 100µL acetonitrile before injecting 30µL into a liquid chromatograph with a mobile phase composed of acetonitrile/0.1% (v/v) formic acid under gradient elution. Quantification limits were in the range 3.6 to 125ngmL(-1). The recoveries obtained were in the 91-119% range, with RSDs lower than 14%. The ESI-MS/MS spectra permitted the correct identification of both APs and APEOs in the fruit juice samples. Copyright © 2016 Elsevier B.V. All rights reserved.
Effects of Current Guides Destruction at Ultra-fast Acceleration of Macrobodies
NASA Astrophysics Data System (ADS)
Kataev, V. N.; Boriskin, A. S.; Golosov, S. N.; Demidov, V. A.; Klimashov, M. V.; Korolev, P. V.; Makartsev, G. F.; Pikar, A. S.; Russkov, A. S.; Shapovalov, E. V.; Shibitov, Yu. M.
2006-08-01
The paper is devoted to discussion of current guides destruction effects in different accelerators: thermal-electric and electro-magnetic rail accelerator at macrobodies acceleration value of 108-109 m/s2. Experimental results with thermal-electric accelerators powering from megajoule capacitor battery and helical magneto-cumulative generator MCG-100 at currents up to 3.5 MA are analyzed. The process of rails destruction at railgun at pressure magnetic field excess over the limit of metal fluidity is presented. Methods of efficiency coefficient increase of capacitive storage energy transmission to kinetic energy of accelerating body are discussed.
Pattern Recognition of the Multiple Sclerosis Syndrome
Stewart, Renee; Healey, Kathleen M.
2017-01-01
During recent decades, the autoimmune disease neuromyelitis optica spectrum disorder (NMOSD), once broadly classified under the umbrella of multiple sclerosis (MS), has been extended to include autoimmune inflammatory conditions of the central nervous system (CNS), which are now diagnosable with serum serological tests. These antibody-mediated inflammatory diseases of the CNS share a clinical presentation to MS. A number of practical learning points emerge in this review, which is geared toward the pattern recognition of optic neuritis, transverse myelitis, brainstem/cerebellar and hemispheric tumefactive demyelinating lesion (TDL)-associated MS, aquaporin-4-antibody and myelin oligodendrocyte glycoprotein (MOG)-antibody NMOSD, overlap syndrome, and some yet-to-be-defined/classified demyelinating disease, all unspecifically labeled under MS syndrome. The goal of this review is to increase clinicians’ awareness of the clinical nuances of the autoimmune conditions for MS and NMSOD, and to highlight highly suggestive patterns of clinical, paraclinical or imaging presentations in order to improve differentiation. With overlay in clinical manifestations between MS and NMOSD, magnetic resonance imaging (MRI) of the brain, orbits and spinal cord, serology, and most importantly, high index of suspicion based on pattern recognition, will help lead to the final diagnosis. PMID:29064441
Increased confinement and beta by inductive poloidal current drive in the RFP
DOE Office of Scientific and Technical Information (OSTI.GOV)
Sarff, J.S.; Lanier, N.E.; Prager, S.C.
1996-10-01
Progress in understanding magnetic-fluctuation-induced transport in the reversed field pinch (RFP) has led to the idea of current profile control to reduce fluctuations and transport. With the addition of inductive poloidal current drive in the Madison Symmetric Torus (MST), the magnetic fluctuation amplitude is halved, leading to a four- to five-fold increase in the energy confinement time to {tau}{sub E}{approximately}5 ms as a result of both decreased plasma resistance and increased stored thermal energy. The record low fluctuation amplitude coincides with a record high electron temperature of {approximately}600 eV (for MST), and beta {beta} = 2{mu}{sub 0} / B(a){sup 2}more » increases from 6% to 8% compared with conventional MST RFP plasmas. Other improvements include increased particle confinement and impurity reduction. 19 refs., 4 figs., 1 tab.« less
On the apparent velocity of integrated sunlight. I - 1983-1985
NASA Technical Reports Server (NTRS)
Deming, Drake; Espenak, Fred; Jennings, Donald E.; Brault, James W.; Wagner, Jeremy
1987-01-01
Frequency measurements for the Delta V = 2 transitions of CO in the integrated light spectrum of the sun are presented. The nature and magnitude of systematic errors which typically arise in absolute velocity measurements of integrated sunlight are explored in some detail, and measurements believed accurate at the level of about 5 m/s or less are presented. It is found that the integrated light velocity varies by about 3 m/s or less over a one-day period. Over the long term, the data indicate an increasing blue-shift in these weak infrared lines amounting to 30 m/s from 1983 to 1985. The sense of the drift is consistent with a lessening in the magnetic inhibition of granular convection at solar minimum. Such an effect has implications for the spectroscopic detectability of planetary-mass companions to solar-type stars.
Effect of annealing temperature on the size and magnetic properties of CoFe2O4 nanoparticle
NASA Astrophysics Data System (ADS)
Sunny, Annrose; Akshay, V. R.; Vasundhara, M.
2018-05-01
CoFe2O4 (CFO) nanoparticles (NPs) are synthesized using sol gel method and are annealed at 400, 600 and 800 °C for 4h. The crystal structure and morphology of the NPs are investigated through XRD and TEM analysis. The X- ray diffraction analysis shows that all the samples are well formed and attain a cubic structure with Fd-3m space group. The morphology of the material is found to be polygonal and the particle size of the NPs is increased with increase of annealing temperature as 400, 600 and 800 to be 20 nm, 30 nm and 70 nm respectively. The magnetic properties of the NPs are investigated using VSM and observed that the curie temperature for 400, 600 and 800 °C annealing temperature are 762 K, 780 K, 769 K respectively. The Ms of 600 sample is 80 emu/g. The 400 and 800 sample shows lower Ms value this is due to poor crystalanity and exaggerated grain growth at the respective temperatures. The coercivity of the sample shows linear dependence with particle size of the material the highest coercivity is obtained for 400 sample and low value for 800 sample.
Iron nanoparticles with tunable tetragonal structure and magnetic properties
NASA Astrophysics Data System (ADS)
Liu, Jinming; Schliep, Karl; He, Shi-Hai; Ma, Bin; Jing, Ying; Flannigan, David J.; Wang, Jian-Ping
2018-05-01
Body-centered cubic (bcc) Fe is known as a typical soft magnetic material with high-saturation magnetization (Ms) and low magnetocrystalline anisotropy. However, first-principles calculations demonstrate that body-centered tetragonal (bct) Fe has higher magnetocrystalline anisotropy than bcc Fe and comparable Ms. In this work, bct Fe nanoparticles (NPs) were successfully fabricated by a gas-phase condensation method for the first time. The bct Fe phase is confirmed by the x-ray diffraction pattern and diffraction images of transmission electron microscopy. An increased magnetocrystalline anisotropy of bct Fe, (2.65 ±0.67 ) ×1 05J /m3 [ (21.2 ±5.3 ) μ eV /atom ], is observed, which is around seven times higher than that of bcc Fe 4.8 ×1 04J /m3 (3.5 μ eV /atom ). The bct Fe NPs sample has coercivity of 3.22 ×1 05 A/m at 5 K and 1.0 4 ×1 05 A/m at 300 K, which are much higher than that of bcc Fe NPs. In addition, the saturation magnetization at 5 K is estimated to be (1.6 ±0.4 ) ×1 06 A/m (2.2 ±0.5 μB/atom ), comparable to that of bcc Fe 1.7 ×1 06 A/m (2.2 μB/atom ).
Thermoconvective flow velocity in a high-speed magnetofluid seal after it has stopped
NASA Astrophysics Data System (ADS)
Krakov, M. S.; Nikiforov, I. V.
2012-09-01
Convective flow is investigated in the high-speed (linear velocity of the shaft seal is more than 1 m/s) magnetofluid shaft seal after it has been stopped. Magnetic fluid is preliminarily heated due to viscous friction in the moving seal. After the shaft has been stopped, nonuniform heated fluid remains under the action of a high-gradient magnetic field. Numerical analysis has revealed that in this situation, intense thermomagnetic convection is initiated. The velocity of magnetic fluid depends on its viscosity. For the fluid with viscosity of 2 × 10-4 m2/s the maximum flow velocity within the volume of magnetic fluid with a characteristic size of 1 mm can attain a value of 10 m/s.
NASA Astrophysics Data System (ADS)
Song, Dongsheng; Li, Zi-An; Caron, Jan; Kovács, András; Tian, Huanfang; Jin, Chiming; Du, Haifeng; Tian, Mingliang; Li, Jianqi; Zhu, Jing; Dunin-Borkowski, Rafal E.
2018-04-01
Whereas theoretical investigations have revealed the significant influence of magnetic surface and edge states on Skyrmonic spin texture in chiral magnets, experimental studies of such chiral states remain elusive. Here, we study chiral edge states in an FeGe nanostripe experimentally using off-axis electron holography. Our results reveal the magnetic-field-driven formation of chiral edge states and their penetration lengths at 95 and 240 K. We determine values of saturation magnetization MS by analyzing the projected in-plane magnetization distributions of helices and Skyrmions. Values of MS inferred for Skyrmions are lower by a few percent than those for helices. We attribute this difference to the presence of chiral surface states, which are predicted theoretically in a three-dimensional Skyrmion model. Our experiments provide direct quantitative measurements of magnetic chiral boundary states and highlight the applicability of state-of-the-art electron holography for the study of complex spin textures in nanostructures.
Size distribution of magnetic iron oxide nanoparticles using Warren-Averbach XRD analysis
NASA Astrophysics Data System (ADS)
Mahadevan, S.; Behera, S. P.; Gnanaprakash, G.; Jayakumar, T.; Philip, J.; Rao, B. P. C.
2012-07-01
We use the Fourier transform based Warren-Averbach (WA) analysis to separate the contributions of X-ray diffraction (XRD) profile broadening due to crystallite size and microstrain for magnetic iron oxide nanoparticles. The profile shape of the column length distribution, obtained from WA analysis, is used to analyze the shape of the magnetic iron oxide nanoparticles. From the column length distribution, the crystallite size and its distribution are estimated for these nanoparticles which are compared with size distribution obtained from dynamic light scattering measurements. The crystallite size and size distribution of crystallites obtained from WA analysis are explained based on the experimental parameters employed in preparation of these magnetic iron oxide nanoparticles. The variation of volume weighted diameter (Dv, from WA analysis) with saturation magnetization (Ms) fits well to a core shell model wherein it is known that Ms=Mbulk(1-6g/Dv) with Mbulk as bulk magnetization of iron oxide and g as magnetic shell disorder thickness.
Study of the preparation of NI-Mn-Zn ferrite using spent NI-MH and alkaline Zn-Mn batteries
NASA Astrophysics Data System (ADS)
Xi, Guoxi; Xi, Yuebin; Xu, Huidao; Wang, Lu
2016-01-01
Magnetic nanoparticles of Ni-Mn-Zn ferrite have been prepared by a sol-gel method making use of spent Ni-MH and Zn-Mn batteries as source materials. Characterization by X-ray diffraction was carried out to study the particle size. The presence of functional groups was identified by Fourier transform infrared spectroscopy. From studies by thermogravimetry and differential scanning calorimetry, crystallization occurred at temperatures above 560 °C. The magnetic properties of the final products were found to be directly influenced by the average particle size of the product. The Ms values increase and the Hc values decrease as the size of the Ni-Mn-Zn ferrite particles increases.
Multi-platform metabolomics assays for human lung lavage fluids in an air pollution exposure study.
Surowiec, Izabella; Karimpour, Masoumeh; Gouveia-Figueira, Sandra; Wu, Junfang; Unosson, Jon; Bosson, Jenny A; Blomberg, Anders; Pourazar, Jamshid; Sandström, Thomas; Behndig, Annelie F; Trygg, Johan; Nording, Malin L
2016-07-01
Metabolomics protocols are used to comprehensively characterize the metabolite content of biological samples by exploiting cutting-edge analytical platforms, such as gas chromatography (GC) or liquid chromatography (LC) coupled to mass spectrometry (MS) assays, as well as nuclear magnetic resonance (NMR) assays. We have developed novel sample preparation procedures combined with GC-MS, LC-MS, and NMR metabolomics profiling for analyzing bronchial wash (BW) and bronchoalveolar lavage (BAL) fluid from 15 healthy volunteers following exposure to biodiesel exhaust and filtered air. Our aim was to investigate the responsiveness of metabolite profiles in the human lung to air pollution exposure derived from combustion of biofuels, such as rapeseed methyl ester biodiesel, which are increasingly being promoted as alternatives to conventional fossil fuels. Our multi-platform approach enabled us to detect the greatest number of unique metabolites yet reported in BW and BAL fluid (82 in total). All of the metabolomics assays indicated that the metabolite profiles of the BW and BAL fluids differed appreciably, with 46 metabolites showing significantly different levels in the corresponding lung compartments. Furthermore, the GC-MS assay revealed an effect of biodiesel exhaust exposure on the levels of 1-monostearylglycerol, sucrose, inosine, nonanoic acid, and ethanolamine (in BAL) and pentadecanoic acid (in BW), whereas the LC-MS assay indicated a shift in the levels of niacinamide (in BAL). The NMR assay only identified lactic acid (in BW) as being responsive to biodiesel exhaust exposure. Our findings demonstrate that the proposed multi-platform approach is useful for wide metabolomics screening of BW and BAL fluids and can facilitate elucidation of metabolites responsive to biodiesel exhaust exposure. Graphical Abstract Graphical abstract illustrating the study workflow. NMR Nuclear Magnetic Resonance, LC-TOFMS Liquid chromatography-Time Of Flight Mass Spectrometry, GC Gas Chromatography-Mass spectrometry.
NASA Astrophysics Data System (ADS)
Menshov, Oleksandr; Pereira, Paulo; Kruglov, Oleksandr
2015-04-01
Magnetic susceptibility (MS) have been used to characterize soil properties. It gives an indirect information about heavy metals content and degree of human impacts on soil contamination derived from atmospheric pollution (Girault et al., 2011). This method is inexpensive in relation to chemical analysis and very useful to track soil pollution, since several toxic components deposited on soil surface are rich in particulates produced by oxidation processes (Boyko et al., 2004; Morton-Bernea et al., 2009). Thus, identify the spatial distribution of MS is of major importance, since can give an indirect information of high metals content (Dankoub et al., 2012). This allows also to distinguish the pedogenic and technogenic origin magnetic signal. For example Ukraine chernozems contain fine-grained oxidized magnetite and maghemite of pedogenic origin formed by weathering of the parent material (Jeleńska et al., 2004). However, to a correct understanding of variables distribution, the identification of the most accurate interpolation method is fundamental for a better interpretation of map information (Pereira et al., 2013). The objective of this work is to study the spatial variability of soil MS in an agricultural fields located in the Tcherkascy Tishki area (50.11°N, 36.43 °E, 162 m a.s.l), Ukraine. Soil MS was measured in 77 sampling points in a north facing slope. To estimate the best interpolation method, several interpolation methods were tested, as inverse distance to a weight (IDW) with the power of 1,2,3,4 and 5, Local Polynomial (LP) with the power of 1 and 2, Global Polynomial (GP), radial basis functions - spline with tension (SPT), completely regularized spline (CRS), multiquatratic (MTQ), inverse multiquatratic (IMTQ), and thin plate spline (TPS) - and some geostatistical methods as, ordinary kriging (OK), Simple Kriging (SK) and Universal Kriging (UK), used in previous works (Pereira et al., 2014). On average, the soil MS of the studied plot had 686.05 MS×10-9 m3/kg, and a minimum and a maximum value of 499.33 and 862.27 MS×10-9 m3/kg respectively. The standard deviation was 85.62 and the coefficient of variation 12.48%. This shows that the spatial variability of soil MS was low. The Global Morans I index was of 0.841, a z-score of 7.741 with a p<0.001, indicating that soil MS had a clustered pattern. The variogram results showed that the gaussian model was the the best fitted. The nugget effect was 0.1007. the sill 0.9905 and the nugget/sill ratio of 0.10, which shows that soil MS has a strong spatial dependency. The results of the interpolation tests showed that the errors distribution followed the normal distribution, the average predicted values were similar to the observed and the correlation between these two distributions was high (between 0.85-0.90) in all the cases. The method that predicted better soil MS was LP2 and the less accurate was SK. Soil MS presented high values in the southwestern part and low in the northeast area of the plot. It is clearly observed a increase of soil MS from the top of the slope to the bottom. Acknowledgments RECARE (Preventing and Remediating Degradation of Soils in Europe Through Land Care, FP7-ENV-2013-TWO STAGE), funded by the European Commission; and for the COST action ES1306 (Connecting European connectivity research). References Boyko, T., Scholger, R., Stanjek, H., MAGPROX team (2004) Topsoil magnetic suseptibility mapping as a tool for pollution monitoring: Repetability of in situ measurments. Journal of Applied Geophysics, 55, 249-259. Dankoub, Z., Ayoubi, S., Khademi, H., Sheng-Gao, L. (2012) Spatial distribution of magnetic properties and selected heavy metals in calcareous soils as affected by land use in the Isfahan Region, Central Iran. Pedosphere, 22, 33-47. Girault, F., Poitou, C., Perrier, F., Koirala, B.P., Bhattarai, M. (2011) Soil characterization using patterns of magnetic susceptibility versus effective radimu concentration. Natural Hazards Earth System Science, 11, 2285-2293. Jeleńska, M., Hasso-Agopsowicz, A., Kopcewicz, B., Sukhorada, A., Tyamina, K., Kądziałko-Hofmokl, M., Matviishina, Z. (2004) Magnetic properties of the profiles of polluted and non-polluted soils. A case study from Ukraine. Geophys. J. Int., 159, 104-116. Morton-Bernea, O., Hernandez, E., Martinez-Pichardo, E., Soler-Arechalde, A.M., Santa Cruz, R.L., Gonzalez-Hernandez, G., Beramendi-Orosco, L., Urritia-Fucugaushi, J. (2009) Mexico city topsoils: Heavy metals vs. magnetic susceptibility. Geoderma, 151, 121-125. Pereira, P., Cerdà, A., Úbeda, X., Mataix-Solera, J. Arcenegui, V., Zavala, L. Modelling the impacts of wildfire on ash thickness in a short-term period, Land Degradation and Development, (In Press), DOI: 10.1002/ldr.2195 Pereira, P., Cerdà, A., Úbeda, X., Mataix-Solera, J., Jordan, A. Burguet, M. (2013) Spatial models for monitoring the spatio-temporal evolution of ashes after fire - a case study of a burnt grassland in Lithuania, Solid Earth, 4, 153-165.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Singh, S. V.; Devanandhan, S.; Lakhina, G. S.
2013-01-15
Obliquely propagating ion-acoustic soliatry waves are examined in a magnetized plasma composed of kappa distributed electrons and fluid ions with finite temperature. The Sagdeev potential approach is used to study the properties of finite amplitude solitary waves. Using a quasi-neutrality condition, it is possible to reduce the set of equations to a single equation (energy integral equation), which describes the evolution of ion-acoustic solitary waves in magnetized plasmas. The temperature of warm ions affects the speed, amplitude, width, and pulse duration of solitons. Both the critical and the upper Mach numbers are increased by an increase in the ion temperature.more » The ion-acoustic soliton amplitude increases with the increase in superthermality of electrons. For auroral plasma parameters, the model predicts the soliton speed, amplitude, width, and pulse duration, respectively, to be in the range of (28.7-31.8) km/s, (0.18-20.1) mV/m; (590-167) m, and (20.5-5.25) ms, which are in good agreement with Viking observations.« less
Lund, Anders L.; Slater, Lee D.; Atekwana, Estella A.; Ntarlagiannis, Dimitrios; Cozzarelli, Isabelle M.; Bekins, Barbara A.
2017-01-01
Conventional characterization and monitoring of hydrocarbon (HC) pollution is often expensive and time-consuming. Magnetic susceptibility (MS) has been proposed as an inexpensive, long-term monitoring proxy of the degradation of HC. We acquired repeated down hole MS logging data in boreholes at a HC-contaminated field research site in Bemidji, MN, USA. The MS data were analyzed in conjunction with redox conditions and iron availability within the source zone to better assess whether MS can serve as a proxy for monitoring HC contamination in unconsolidated sediments. The MS response at the site diminished during the sampling period, which was found to coincide with depletion of solid phase iron in the source zone. Previous geochemical observations and modeling at the site suggest that the most likely cause of the decrease in MS is the transformation of magnetite to siderite, coupled with the exhaustion of ferrihydrite. Although the temporal MS response at this site gives valuable field-scale evidence for changing conditions of iron cycling and stability of iron minerals it does not provide a simple proxy for long-term monitoring of biodegradation of hydrocarbons in the smear zone.
Ferromagnetic resonance in bulk nanocrystalline Ni
NASA Astrophysics Data System (ADS)
Prakash Madduri, P. V.; Mathew, S. P.; Kaul, S. N.
2018-03-01
A detailed lineshape analysis of the ferromagnetic resonance (FMR) spectra taken on pulse electrodeposited nanocrystalline (nc-) Ni sheets (with the average crystallite size, d, varying from 10 nm to 40 nm) at temperatures ranging from 113 K to 325 K yield accurate values for saturation magnetization, Ms (T), Landé splitting factor, g, anisotropy field, Hk (T) , resonance field, Hres , and FMR linewidth, ΔHpp (T) . Thermally-excited spin-wave (SW) excitations completely account for Ms (T) and the SW description of Ms (T) gives the values for the saturation magnetization and spin-wave stiffness at absolute zero of temperature, i.e., Ms (0) and D0 , for nc-Ni samples of different d that are in excellent agreement with the corresponding values deduced previously from an elaborate SW analysis of the bulk magnetization data. While Ms (0) varies with d as Ms (0) d - 3 / 2,D0 follows the power law D0 ∼d 4 / 3 . The angular variations of Hres in the 'in-plane' as well as 'out-of-plane' sample configurations, demonstrate that the main contribution to Hk (T) comes from the cubic magnetocrystalline anisotropy. The exchange-conductivity mechanism describes the observed thermal decline of ΔHpp reasonably well but fails to explain the very large magnitude of ΔHpp at any given temperature. By comparison, the Landau-Lifshitz-Gilbert (LLG) damping gives a much greater contribution to ΔHpp but the LLG contribution is relatively insensitive to temperature.
NASA Astrophysics Data System (ADS)
Wang, C.; Slater, L. D.; Day-Lewis, F. D.; Briggs, M. A.
2017-12-01
Redox reactions occurring at the oxic/anoxic interface where groundwater discharges to surface water commonly result in iron oxide deposition that coats sediment grains. With relatively large total surface area, these iron oxide coated sediments serve as a sink for sorption of dissolved contaminants, although this sink may be temporary if redox conditions fluctuate with varied flow conditions. Characterization of the distribution of iron oxides in streambed sediments could provide valuable understanding of biogeochemical reactions and the ability of a natural system to sorb contaminants. Towards developing a field methodology, we conducted laboratory spectral induced polarization (SIP) and magnetic susceptibility (MS) measurements on natural iron oxide coated sand (Fe-sand) with grain sizes ranging from 0.3 to 2.0 mm in order to assess the sensitivity of these measurements to iron oxides in sediments. The Fe-sand was also sorted by sieving into various grain sizes to study the impact of grain size on the polarization mechanisms. The unsorted Fe-sand saturated with 0.01 S/m NaCl solution exhibited a distinct phase response ( > 4 mrad) in the frequency range from 0.001 to 100 Hz whereas regular silica sand was characterized by a phase response less than 1 mrad under the same conditions. The presence of iron oxide substantially increased MS (3.08×10-3 SI) over that of regular sand ( < 10-5 SI). An increase of both phase peak and relaxation time was found with increasing grain size of the sorted Fe-sand. Laboratory results demonstrated that SIP and MS may be well suited to mapping the distribution of iron oxides in streambed sediments associated with anoxic groundwater discharge.
Tlili-Graiess, Kalthoum; Mama, Nadia; Arifa, Nadia; Kadri, Khaled; Hasni, Ibtissem; Krifa, Hedi; Mokni, Moncef
2014-10-01
Three cases of histopathologically confirmed central neurocytoma (CN) are presented, emphasizing diagnostic imaging issues: conventional magnetic resonance imaging with Proton magnetic resonance spectroscopy (MRS) and diffusion-weighted imaging (DWI) findings of CN. Patients age ranged from 17 to 32 years, Imaging include a CT scan and MR examination with DWI and proton MRS on a 1.5-T system. DWI and subsequent apparent diffusion coefficient (ADC) were obtained in all. Single voxel MRS was performed prior to surgery using a point resolved spectroscopy sequence (PRESS) with short 35 ms and long echotime (TE) 144 ms, associated with a two-dimensional chemical Shift Imaging (2D-CSI) with 144 ms TE (one case). Histopathological examination included immunostaining with synaptophysin. With the long TE, a variable amount of glycine with markedly increased choline, very small to almost complete loss of N-acetylaspartate and creatine, and inverted triplet of alanine-lactate were observed in all three patients. Increased glutamate and glutamine complex (Glx) was also observed in all with short TE. DWI demonstrated variable low ADC which appeared well correlated with the tumor signal intensity and cell density: the most homogeneous and highly dense cellular tumor with increased nucleus to cytoplasm ratio demonstrated the lower ADC. Histological pattern was typical in two cases and demonstrated an oligodendroglioma-like pattern in one case. Positivity for synaptophysin confirmed the neuronal origin in all. The demonstration within an intraventricular tumor of both glycine and alanine on MRS along with high choline, bulky Glx and restricted diffusion appear diagnostic of CN. Copyright © 2013 Elsevier Masson SAS. All rights reserved.
Magnetic Ordering of Antiferromagnetic Trimer System 2b·3CuCl2·2H2O
NASA Astrophysics Data System (ADS)
Sanda, M.; Kubo, K.; Asano, T.; Morodomi, H.; Inagaki, Y.; Kawae, T.; Wang, J.; Matsuo, A.; Kindo, K.; Sato, T. J.
2012-12-01
In this paper, we present the magnetic properties of 2b·3CuCl2·2H2O (b = betaine, C5H11NO2). 2b·3CuCl2·2H2O is the first model substance for a two-dimensional S = 1/2 orthogonal antiferromagnetic trimer system. We have performed magnetic susceptibility, magnetization curve, and specific heat under extreme conditions: low temperatures and high magnetic fields in this system. The experimental results indicate that this substance is a magnetically S = 1/2 antiferromagnetic trimer system. The magnetization also shows one-third of the saturation value (MS ~ 3.2μB/f.u.) between 5 and 14T The specific heat in a zero field shows a sharp peak at 1.38K corresponding to a long-range magnetic ordering, TN. As the magnetic field increases, the TN shifts remarkably to a lower temperature and is suppressed. Above 5T, the specific heat has no anomaly down to 150mK In the plateau region with an energy gap, the magnetic ordering seems to be disappeared.
NASA Astrophysics Data System (ADS)
Ghimire, M.; Yoon, S.; Wang, L.; Neupane, D.; Alam, J.; Mishra, S. R.
2018-05-01
The present study investigates the influence of Cu2+ and La3+-Cu2+ doping on the magnetic properties of Sr1-xLaxFe12-xCuxO19 (x = 0.0-0.5) hexaferrite (SrM) compounds. The samples were prepared via facile autocombustion technique followed by sintering. X-ray powder diffraction patterns show the formation of the pure phase of M-type hexaferrite for all x. Invariance in lattice parameters was observed with only Cu2+ substitution while lattice contraction along c-axis was observed with co-doping La3+-Cu2+ in SrM. The magnetic property of these compounds is explained based on Cu2+ occupancy in the absence and presence of La3+ in SrM magnetoplumbite structure. The Cu2+ doped SrFe12-xCuxO19 sample showed a monotonic decrease in Ms value while La3+-Cu2+ showed a noticeable increase in Ms value with x. Furthermore, while coercivity of Cu2+ doped SrM reduced with x, the coercivity of La3+-Cu2+ doped SrM showed a marked 12% increase in coercivity at x = 0.1 (Hc = 4391 Oe) from that of x = 0.0 (3918 Oe). Interestingly, Cu2+ doped SrM displayed invariance in Tc ∼ 458.6 °C with x, while La3+-Cu2+ doping reduced Tc by 5% from its x = 0 (Tc = 451.9 °C) to 429.6 °C. The room temperature Mossbauer spectral analysis confirmed a Cu2+ preference for the 12k site and its occupancy is observed to be influenced by the presence of La3+ ion at the Sr2+ site.
Lee, Linda L.; Puchowicz, Michelle; Golub, Mari S.; Befroy, Douglas E.; Wilson, Dennis W.; Anderson, Steven; Cline, Gary; Bini, Jason; Borkowski, Kamil; Knotts, Trina A.; Rutledge, John C.
2018-01-01
Recent work suggests that diet affects brain metabolism thereby impacting cognitive function. Our objective was to determine if a western diet altered brain metabolism, increased blood-brain barrier (BBB) transport and inflammation, and induced cognitive impairment in C57BL/6 (WT) mice and low-density lipoprotein receptor null (LDLr -/-) mice, a model of hyperlipidemia and cognitive decline. We show that a western diet and LDLr -/- moderately influence cognitive processes as assessed by Y-maze and radial arm water maze. Also, western diet significantly increased BBB transport, as well as microvessel factor VIII in LDLr -/- and microglia IBA1 staining in WT, both indicators of activation and neuroinflammation. Interestingly, LDLr -/- mice had a significant increase in 18F- fluorodeoxyglucose uptake irrespective of diet and brain 1H-magnetic resonance spectroscopy showed increased lactate and lipid moieties. Metabolic assessments of whole mouse brain by GC/MS and LC/MS/MS showed that a western diet altered brain TCA cycle and β-oxidation intermediates, levels of amino acids, and complex lipid levels and elevated proinflammatory lipid mediators. Our study reveals that the western diet has multiple impacts on brain metabolism, physiology, and altered cognitive function that likely manifest via multiple cellular pathways. PMID:29444171
NASA Astrophysics Data System (ADS)
Satolli, S.; Muttoni, G.; Di Cencio, A.; Lanci, L.
2017-12-01
The early Toarcian is globally characterized by a concomitance of extensional tectonics, volcanism, greenhouse conditions, marine transgression, mass extinction and increase in the total organic carbon, generally resulting in an organic rich facies known as the Toarcian oceanic anoxic event (T-OAE). These events have been related to the eruption of the Karoo-Ferrar igneous province. We characterize the time interval encompassing the T-OAE in the Marne del Serrone section (Northern Apennines, Italy). This 62-m-thick section is characterized by micritic limestones, red-green marls and by 50-cm-thick black shale and massive slumps in its bottom part. The age of the section has been constrained trough magnetostratigraphy and ammonite biostratigraphy in the Spinatum to Variabilis biozones. Non-oriented samples were collected at 5-to-10-cm sampling space and analyzed in order to detect variations in the magnetic minerals content. Rock magnetic investigations comprise mass-normalized NRM and magnetic susceptibility (MS), isothermal remanent magnetization (IRM) at room temperature, and thermal demagnetization of a three-component IRM. The section is magnetic-wise characterized by an alternate predominance of two end-members: magnetite and hematite. Higher SIRM coupled with lower S-ratio documented in red levels and nodular grey-reddish marl indicates higher presence of hematite, suggesting a detrital input. Instead, the black shale is characterized by a comparably high amount of magnetite. Here, the absence of hematite suggests the lack of continental influx. The cyclicity of rock magnetic parameters S-ratio and MS record was studied as a proxy for changes in productivity due to fluctuations in hematite of detrital origin. The latter reflects the expression of orbital modulation on the lithological alternations found in the upper part of the section (Bifrons biozone). The analysis allowed quantifying the timing and duration of the environmental change triggered by the Karoo-Ferrar event, which in the Marne del Serrone section is mirrored by a rapid increase in the SIRM starting in the "Posidonia Beds" and reaches its acme few meters above the anoxic level. The decrease in the magnetization of saturation is gradual after the event and characterized by peaks in the magnetization intensity.
Magnetism of Al-substituted magnetite reduced from Al-hematite
NASA Astrophysics Data System (ADS)
Jiang, Zhaoxia; Liu, Qingsong; Zhao, Xiang; Roberts, Andrew P.; Heslop, David; Barrón, Vidal; Torrent, José
2016-06-01
Aluminum-substituted magnetite (Al-magnetite) reduced from Al-substituted hematite or goethite (Al-hematite or Al-goethite) is an environmentally important constituent of magnetically enhanced soils. In order to characterize the magnetic properties of Al-magnetite, two series of Al-magnetite samples were synthesized through reduction of Al-hematite by a mixed gas (80% CO2 and 20% CO) at 395°C for 72 h in a quartz tube furnace. Al-magnetite samples inherited the morphology of their parent Al-hematite samples, but only those transformed from Al-hematite synthesized at low temperature possessed surficial micropores, which originated from the release of structural water during heating. Surface micropores could thus serve as a practical fingerprint of fire or other high-temperature mineralogical alteration processes in natural environments, e.g., shear friction in seismic zones. In addition, Al substitution greatly affects the magnetic properties of Al-magnetite. For example, coercivity (Bc) increases with increasing Al content and then decreases slightly, while the saturation magnetization (Ms), Curie temperature (Tc), and Verwey transition temperature (Tv) all decrease with increasing Al content due to crystal defect formation and dilution of magnetic ions caused by Al incorporation. Moreover, different trends in the correlation between Tc and Bc can be used to discriminate titanomagnetite from Al-magnetite, which is likely to be important in environmental and paleomagnetic studies, particularly in soil.
Thimm, Andreas; Funke, Klaus
2015-02-15
Theta-burst stimulation (TBS) applied via transcranial magnetic stimulation is able to modulate human cortical excitability. Here we investigated in a rat model how two different forms of TBS, intermittent (iTBS) and continuous (cTBS), affect sensory responses in rat barrel cortex. We found that iTBS but less cTBS promoted late (>18 ms) sensory response components while not affecting the earliest response (8-18 ms). The effect increased with each of the five iTBS blocks applied. cTBS somewhat reduced the early response component after the first block but had a similar effect as iTBS after four to five blocks. We conclude that iTBS primarly modulates the activity of (inhibitory) cortical interneurons while cTBS may first reduce general neuronal excitability with a single block but reverse to iTBS-like effects with application of several blocks. Cortical sensory processing varies with cortical state and the balance of inhibition to excitation. Repetitive transcranial magnetic stimulation (rTMS) has been shown to modulate human cortical excitability. In a rat model, we recently showed that intermittent theta-burst stimulation (iTBS) applied to the corpus callosum, to activate primarily supragranular cortical pyramidal cells but fewer subcortical neurons, strongly reduced the cortical expression of parvalbumin (PV), indicating reduced activity of fast-spiking interneurons. Here, we used the well-studied rodent barrel cortex system to test how iTBS and continuous TBS (cTBS) modulate sensory responses evoked by either single or double stimuli applied to the principal (PW) and/or adjacent whisker (AW) in urethane-anaesthetized rats. Compared to sham stimulation, iTBS but not cTBS particularly enhanced late (>18 ms) response components of multi-unit spiking and local field potential responses in layer 4 but not the very early response (<18 ms). Similarly, only iTBS diminished the suppression of the second response evoked by paired PW or AW-PW stimulation at 20 ms intervals. The effects increased with each of the five iTBS blocks applied. With cTBS a mild effect similar to that of iTBS was first evident after 4-5 stimulation blocks. Enhanced cortical c-Fos and zif268 expression but reduced PV and GAD67 expression was found only after iTBS, indicating increased cortical activity due to lowered inhibition. We conclude that iTBS but less cTBS may primarily weaken a late recurrent-type cortical inhibition mediated via a subset of PV+ interneurons, enabling stronger late response components believed to contribute to the perception of sensory events. © 2014 The Authors. The Journal of Physiology © 2014 The Physiological Society.
Modulation of channel activity and gadolinium block of MscL by static magnetic fields.
Petrov, Evgeny; Martinac, Boris
2007-02-01
The magnetic field of the Earth has for long been known to influence the behaviour and orientation of a variety of living organisms. Experimental studies of the magnetic sense have, however, been impaired by the lack of a plausible cellular and/or molecular mechanism providing meaningful explanation for detection of magnetic fields by these organisms. Recently, mechanosensitive (MS) ion channels have been implied to play a role in magnetoreception. In this study we have investigated the effect of static magnetic fields (SMFs) of moderate intensity on the activity and gadolinium block of MscL, the bacterial MS channel of large conductance, which has served as a model channel to study the basic physical principles of mechanosensory transduction in living cells. In addition to showing that direct application of the magnetic field decreased the activity of the MscL channel, our study demonstrates for the first time that SMFs can reverse the effect of gadolinium, a well-known blocker of MS channels. The results of our study are consistent with a notion that (1) the effects of SMFs on the MscL channels may result from changes in physical properties of the lipid bilayer due to diamagnetic anisotropy of phospholipid molecules and consequently (2) cooperative superdiamagnetism of phospholipid molecules under influence of SMFs could cause displacement of Gd(3+) ions from the membrane bilayer and thus remove the MscL channel block.
Mode Transitions in Magnetically Shielded Hall Effect Thrusters
NASA Technical Reports Server (NTRS)
Sekerak, Michael J.; Longmier, Benjamin W.; Gallimore, Alec D.; Huang, Wensheng; Kamhawi, Hani; Hofer, Richard R.; Jorns, Benjamin A.; Polk, James E.
2014-01-01
A mode transition study is conducted in magnetically shielded thrusters where the magnetic field magnitude is varied to induce mode transitions. Three different oscillatory modes are identified with the 20-kW NASA-300MS-2 and the 6-kW H6MS: Mode 1) global mode similar to unshielded thrusters at low magnetic fields, Mode 2) cathode oscillations at nominal magnetic fields, and Mode 3) combined spoke, cathode and breathing mode oscillations at high magnetic fields. Mode 1 exhibits large amplitude, low frequency (1-10 kHz), breathing mode type oscillations where discharge current mean value and oscillation amplitude peak. The mean discharge current is minimized while thrust-to-power and anode efficiency are maximized in Mode 2, where higher frequency (50-90 kHz), low amplitude, cathode oscillations dominate. Thrust is maximized in Mode 3 and decreases by 5-6% with decreasing magnetic field strength. The presence or absence of spokes and strong cathode oscillations do not affect each other or discharge current. Similar to unshielded thrusters, mode transitions and plasma oscillations affect magnetically shielded thruster performance and should be characterized during system development.
A preliminary magnetic study of Sawa lake sediments, Southern Iraq
NASA Astrophysics Data System (ADS)
Ameen, Nawrass
2016-04-01
A preliminary magnetic study combined with chemical analyses was carried out in Sawa Lake in Al-Muthanna province, southern Iraq, about 22 km south west of Samawa city (31°18'48.80"N, 45°0'25.25"E). The lake is about 4.74 km length, 1.75 km width and 5.5 m height, it is surrounded by a salt rim which is higher than the lake water by about 2.8 m and sea water by about 18.5 m (Naqash et al., 1977 in Hassan, 2007). The lake is an elongated closed basin with no surface water available to it, it may be fed by groundwater of the Euphrates and Dammam aquifers through system of joints and cracks. This study aims to investigate the concentrations of selected heavy metals as pollutants and magnetic susceptibility (MS) and other magnetic properties of sediment samples from fifty sites collected from the bottom of the lake, the study area lies in an industrial area. The results show spatial variations of MS with mean value of about 4.58 x 10-8 m3 kg-1. Scanning electron microscopy and magnetic mineralogy parameters indicate the dominance of soft magnetic phase like magnetite and presence of hard magnetic phase like hematite. Spatial variations of MS combined with the concentrations of heavy metals suggests the efficiency of magnetic methods as effective, inexpensive and non-time consuming method to outlining the heavy metal pollution. References: Hassan W.F., 2007. The Physio-chemical characteristic of Sawa lake water in Samawa city-Iraq. Marine Mesopotamica, 22(2), 167-179.
Bruno, C; Patin, F; Bocca, C; Nadal-Desbarats, L; Bonnier, F; Reynier, P; Emond, P; Vourc'h, P; Joseph-Delafont, K; Corcia, P; Andres, C R; Blasco, H
2018-01-30
Metabolomics is an emerging science based on diverse high throughput methods that are rapidly evolving to improve metabolic coverage of biological fluids and tissues. Technical progress has led researchers to combine several analytical methods without reporting the impact on metabolic coverage of such a strategy. The objective of our study was to develop and validate several analytical techniques (mass spectrometry coupled to gas or liquid chromatography and nuclear magnetic resonance) for the metabolomic analysis of small muscle samples and evaluate the impact of combining methods for more exhaustive metabolite covering. We evaluated the muscle metabolome from the same pool of mouse muscle samples after 2 metabolite extraction protocols. Four analytical methods were used: targeted flow injection analysis coupled with mass spectrometry (FIA-MS/MS), gas chromatography coupled with mass spectrometry (GC-MS), liquid chromatography coupled with high-resolution mass spectrometry (LC-HRMS), and nuclear magnetic resonance (NMR) analysis. We evaluated the global variability of each compound i.e., analytical (from quality controls) and extraction variability (from muscle extracts). We determined the best extraction method and we reported the common and distinct metabolites identified based on the number and identity of the compounds detected with low analytical variability (variation coefficient<30%) for each method. Finally, we assessed the coverage of muscle metabolic pathways obtained. Methanol/chloroform/water and water/methanol were the best extraction solvent for muscle metabolome analysis by NMR and MS, respectively. We identified 38 metabolites by nuclear magnetic resonance, 37 by FIA-MS/MS, 18 by GC-MS, and 80 by LC-HRMS. The combination led us to identify a total of 132 metabolites with low variability partitioned into 58 metabolic pathways, such as amino acid, nitrogen, purine, and pyrimidine metabolism, and the citric acid cycle. This combination also showed that the contribution of GC-MS was low when used in combination with other mass spectrometry methods and nuclear magnetic resonance to explore muscle samples. This study reports the validation of several analytical methods, based on nuclear magnetic resonance and several mass spectrometry methods, to explore the muscle metabolome from a small amount of tissue, comparable to that obtained during a clinical trial. The combination of several techniques may be relevant for the exploration of muscle metabolism, with acceptable analytical variability and overlap between methods However, the difficult and time-consuming data pre-processing, processing, and statistical analysis steps do not justify systematically combining analytical methods. Copyright © 2017 Elsevier B.V. All rights reserved.
Yadav, Vijayshree; Narayanaswami, Pushpa
2014-12-01
Complementary and alternative medicine (CAM) use in individuals with multiple sclerosis (MS) is common, but its use has been limited by a lack of evidence-based guidance. In March 2014, the American Academy of Neurology published the most comprehensive literature review and evidence-based practice guidelines for CAM use in MS. The guideline author panel reviewed and classified articles according to the American Academy of Neurology therapeutic scheme, and recommendations were linked to the evidence strength. Level A recommendations were found for oral cannabis extract effectiveness in the short term for spasticity-related symptoms and pain and ineffectiveness of ginkgo biloba for cognitive function improvement in MS. Key level B recommendations included: Oral cannabis extract or a synthetic cannabis constituent, tetrahydrocannabinol (THC) is probably ineffective for objective spasticity improvement in the short term; Nabiximols oromucosal cannabinoid spray is probably effective for spasticity symptoms, pain, and urinary frequency, but probably ineffective for objective spasticity outcomes and bladder incontinence; Magnetic therapy is probably effective for fatigue reduction in MS; A low-fat diet with fish oil supplementation is probably ineffective for MS-related relapses, disability, fatigue, magnetic resonance imaging lesions, and quality of life. Several Level C recommendations were made. These included possible effectiveness of gingko biloba for fatigue; possible effectiveness of reflexology for MS-related paresthesias; possible ineffectiveness of the Cari Loder regimen for MS-related disability, symptoms, depression, and fatigue; and bee sting therapy for MS relapses, disability, fatigue, magnetic resonance imaging outcomes, and health-related quality of life. Despite the availability of studies evaluating the effects of oral cannabis in MS, the use of these formulations in United States may be limited due to a lack of standardized, commercial US Food and Drug Administration-regulated preparations. Additionally, significant concern about prominent central nervous system-related adverse effects with cannabis was emphasized in the review. Copyright © 2014 Elsevier HS Journals, Inc. All rights reserved.
Magnetic Susceptibility and Heavy Metals in Guano from South Sulawesi Caves
NASA Astrophysics Data System (ADS)
Rifai, H.; Putra, R.; Fadila, M. R.; Erni, E.; Wurster, C. M.
2018-04-01
Measurement of some magnetic properties have been performed on vertical profile from South Sulawesi caves (Mampu and Bubau) by using low cost, rapid, sensitive and non destructive magnetic method. The aim is to attempt to use magnetic characters as a fingerprint for anthropogenic pollution in the caves. Guano samples were collected every 5 cm at a certain section of Mampu and Bubau cave, South Sulawesi, starting from surface through 300 cm in depth of mampu Cave and 30 cm of Bubau Cave. The magnetic parameters such as magnetic susceptibility and percentage frequency dependence susceptibility were measured using the Bartington MS2-MS2B instruments and supported by X-Ray Fluoroscence (XRF) to know their element composition. The results show that the samples had variations in magnetic susceptibility from 3.5 to 242.6 x 10‑8 m3/kg for Mampu Cave and from 8.6 to 106.5 x 10‑8 m3/kg for Bubau Cave and also magnetic domain. Then, the XRF results show that the caves contain several heavy metals. Magnetic and heavy metal analyses showing that the magnetic minerals in caves are lithogenic (Fe-bearing minerals) in origin and anthropogenic (Zn content) in the caves.
NASA Astrophysics Data System (ADS)
Bian, Lu-peng; Li, Ying; Han, Xu-hao; Cheng, Jin-yun; Qin, Xiao-ning; Zhao, Yan-qiu; Sun, Ji-bing
2018-02-01
New SmCo5 + x wt% Alnico composite ribbons melt-spun at 40 m/s are designed by multi-element addition of Alnico alloy into SmCo5 matrix, and their structure and magnetic properties are investigated. The results show that the main phase in x ≤ 2.5 ribbons is Sm(Co,M)5, whereas the main phase changes into Sm(Co,M)7 at x = 4.0-8.5, and simultaneously that the content of Al-rich and amorphous phases increases with increasing x. The hard magnetic properties of the ribbons are found to improve with an increase in Alnico content, and particularly the average magnetic properties reach maximum, i.e., Hc = 19.6 ± 1.2 kOe, Mr = 47.7 ± 3.4 emu/g and M2T = 59.1 ± 5.6 emu/g, at x = 4.0. The main reasons for such improvement are that the finer grains divided by three grain boundaries exist in main phase, the dispersed Al-Ni and Al-Co-rich phases distribute in grains and grain boundaries, and the Fe-rich Alnico alloying elements dissolve into Sm(Co,M)7 matrix phase. However, when x > 4.0, the gradually increasing Al-Co and amorphous phases lead to the reduction of hard magnetic properties.
Baranovicova, Eva; Mlynarik, Vladimir; Kantorova, Ema; Hnilicova, Petra; Dobrota, Dusan
2016-05-01
A standard magnetic resonance imaging (MRI) investigation of white matter (WM) areas with visible or expected pathology does not explain satisfactorily the relation between pathology and clinical outcome. Therefore, we focused on multicomponent T2 mapping of WM with the intention to characterize the WM, including normal-appearing white matter that has normal and prolonged T2 and lesions, including degenerated tissue. Twenty-nine patients with clinically diagnosed MS and 27 healthy controls underwent MRI examination. T2 mapping of the WM across the two whole MRI slices was carried out. The relative abundance of biologically relevant T2 regions was correlated with age and the expanded disability status scale (EDSS). The relative abundance of the T2 values of water trapped in myelin increased with age in both healthy subjects (p < 0.05) and MS patients (p < 0.05). The relative abundance of intermediate T2 assigned to intra- and extracellular water decreased with age in both groups (p < 0.05) and with EDSS (p < 0.005) in the MS patients. The mixed water pools with a T2 above 110 ms were not related to age, but strongly increased with EDSS (p < 0.000005). Our results suggest that multicomponent T2 mapping of the WM can be a useful parameter for monitoring the progression of MS in patients.
Gabr, Refaat E; Pednekar, Amol S; Govindarajan, Koushik A; Sun, Xiaojun; Riascos, Roy F; Ramírez, María G; Hasan, Khader M; Lincoln, John A; Nelson, Flavia; Wolinsky, Jerry S; Narayana, Ponnada A
2017-08-01
To improve the conspicuity of white matter lesions (WMLs) in multiple sclerosis (MS) using patient-specific optimization of single-slab 3D fluid-attenuated inversion recovery (FLAIR) magnetic resonance imaging (MRI). Sixteen MS patients were enrolled in a prospective 3.0T MRI study. FLAIR inversion time and echo time were automatically optimized for each patient during the same scan session based on measurements of the relative proton density and relaxation times of the brain tissues. The optimization criterion was to maximize the contrast between gray matter (GM) and white matter (WM), while suppressing cerebrospinal fluid. This criterion also helps increase the contrast between WMLs and WM. The performance of the patient-specific 3D FLAIR protocol relative to the fixed-parameter protocol was assessed both qualitatively and quantitatively. Patient-specific optimization achieved a statistically significant 41% increase in the GM-WM contrast ratio (P < 0.05) and 32% increase in the WML-WM contrast ratio (P < 0.01) compared with fixed-parameter FLAIR. The increase in WML-WM contrast ratio correlated strongly with echo time (P < 10 -11 ). Two experienced neuroradiologists indicated substantially higher lesion conspicuity on the patient-specific FLAIR images over conventional FLAIR in 3-4 cases (intrarater correlation coefficient ICC = 0.72). In no case was the image quality of patient-specific FLAIR considered inferior to conventional FLAIR by any of the raters (ICC = 0.32). Changes in proton density and relaxation times render fixed-parameter FLAIR suboptimal in terms of lesion contrast. Patient-specific optimization of 3D FLAIR increases lesion conspicuity without scan time penalty, and has potential to enhance the detection of subtle and small lesions in MS. 1 Technical Efficacy: Stage 1 J. MAGN. RESON. IMAGING 2017;46:557-564. © 2016 International Society for Magnetic Resonance in Medicine.
Zhang, Jiangang; Zhang, Li; Li, Ruijin; Hu, Di; Ma, Nengxuan; Shuang, Shaomin; Cai, Zongwei; Dong, Chuan
2015-03-07
A simple and rapid method that uses synthesized magnetic graphene composites as both an adsorbent for enrichment and as a matrix in MALDI-TOF MS analysis was developed for the detection of nitropolycyclic hydrocarbons (nitro-PAHs) in PM2.5 samples. Three nitro-PAHs were detected down to sub pg μL(-1) levels based on calculations from an instrumental signal-to-noise better than 3, which shows the feasibility of using the new materials in MALDI-TOF MS as a potential powerful analytical approach for the analysis of nitro-PAHs in PM2.5 samples.
Ogawa, Ryo; Kido, Tomoyuki; Nakamura, Masashi; Kido, Teruhito; Kurata, Akira; Uetani, Teruyoshi; Ogimoto, Akiyoshi; Miyagawa, Masao; Mochizuki, Teruhito
2017-03-01
We evaluated the T1 values of segments and slices and the reproducibility in healthy controls, using saturation recovery single-shot acquisition (SASHA) at 3T magnetic resonance imaging. Moreover, we examined the difference in T1 values between hypertrophic cardiomyopathy (HCM) and healthy controls, and compared those with late gadolinium enhancement (LGE). Twenty-one HCM patients and 10 healthy controls underwent T1 mapping before and after contrast administration. T1 values were measured in 12 segments. Native T1 values were significantly longer in HCM than in healthy controls [1373 ms (1312-1452 ms) vs. 1279 ms (1229-1326 ms); p < 0.0001]. Even in HCM segments without LGE, native T1 values were significantly longer than in healthy control segments [1366 ms (1300-1439 ms) vs. 1279 ms (1229-1326 ms); p < 0.0001]. Using a cutoff value of 1327 ms for septal native T1 values, we differentiated between HCM and healthy controls with 95% sensitivity, 90% specificity, 94% accuracy, and an area under the curve of 0.95. Native T1 values using a SASHA at 3T could differentiate HCM from healthy controls. Moreover, native T1 values have the potential to detect abnormal myocardium that cannot be identified adequately by LGE in HCM.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Ray, Sekhar C., E-mail: raysc@unisa.ac.za; Mishra, D. K.; Department of Physics, Institute of Technical Research and Education, Siksha ‘O’ Anusandhan University, Khandagiri Square, Bhubaneswar 751030, Odisha
The electronic structures and magnetic properties of graphene nanoflakes (GNFs) exposed to an organo-silane precursor [tetra-methyl-silane, Si(CH{sub 3}){sub 4}] were studied using atomic force microscopy, electron field emission (EFE), x-ray photoelectron spectroscopy (XPS), and magnetization. The result of XPS indicates that silyl radical based strong covalent bonds were formed in GNFs, which induced local structural relaxations and enhanced sp{sup 3} hybridization. The EFE measurements show an increase in the turn-on electric field from 9.8 V/μm for pure GNFs to 26.3 V/μm for GNFs:Si having highest Si/(Si + C) ratio ( ≅ 0.35) that also suggests an enhancement of the non-metallic sp{sup 3} bonding in the GNFsmore » matrix. Magnetic studies show that the saturation magnetization (Ms) is decreased from 172.53 × 10{sup −6} emu/g for pure GNFs to 13.00 × 10{sup −6} emu/g for GNFs:Si with the highest Si/(Si + C) ratio 0.35, but on the other side, the coercivity (Hc) increases from 66 to 149 Oe due to conversion of sp{sup 2} → sp{sup 3}-hybridization along with the formation of SiC and Si-O bonding in GNFs. The decrease in saturation magnetization and increase in coercivity (Hc) in GNFs on Si-functionalization are another routes to tailor the magnetic properties of graphene materials for magnetic device applications.« less
Magnetic and structural properties of Mn1-xCrxAlGe (0 ≤ x ≤ 1.0)
NASA Astrophysics Data System (ADS)
Masumitsu, Hayato; Yoshinaga, Soshi; Mitsui, Yoshifuru; Umetsu, Rie Y.; Hiroi, Masahiko; Uwatoko, Yoshiya; Koyama, Keiichi
2018-06-01
The magnetic and structural properties of Mn1-xCrxAlGe (0 ≤ x ≤ 1.0) compounds were investigated. The spontaneous magnetization Ms and Curie temperature TC of Mn1-xCrxAlGe has a cusp at x = 0.2. The maximum values of Ms and TC are 1.74 μB/f.u. and 601 K, respectively. It was found that the tetragonal Cu2Sb-type structure was stable for 0 ≤ x ≤ 0.75, whereas orthorhombic TiSi2-type structure was observed for x ≥ 0.8. The reciprocal susceptibility as a function of temperature suggested that the magnetic moment of Cr is antiferromagnetically coupled with that of Mn in Cu2Sb-type structure.
Surfactant assisted synthesis of aluminum doped SrFe{sub 10}Al{sub 2}O{sub 19} hexagonal ferrite
DOE Office of Scientific and Technical Information (OSTI.GOV)
Neupane, D., E-mail: dneupane@memphis.edu; Wang, L.; Mishra, S. R.
2015-05-07
M-type aluminum doped SrFe{sub 10}Al{sub 2}O{sub 19} were synthesized via co-precipitation method using cetyltrimethyl ammonium bromide (CTAB) as a surfactant. The effects of CTAB content (x = 0, 1, 3, and 9 wt. %) on the formation, structure, morphology, magnetic, and dielectric properties of the SrFe{sub 10}Al{sub 2}O{sub 19} nanoparticles were investigated. X-ray diffraction results show elimination of α-Fe{sub 2}O{sub 3} phase from samples prepared using CTAB. Morphological changes including grain and crystallite size was noticed with the increase in the CTAB content. With the increase in CTAB, powder particles grew in hexagonal plates. A linear increase in saturation magnetization, Ms, with CTABmore » content was observed from 56.5 emu/g at 0% CTAB to 66.4 emu/g at 9% CTAB. This is a net increase of 17.5% in Ms. The coercivity (Hc ∼ 5700 Oe) of sample reached maximum at 1% CTAB and reduced with further CTAB content reaching to a minimum value of 4488 Oe at 9% CTAB. A slight increase in Curie temperature (735 K) was also observed for samples synthesized using CTAB as compared to that of sample prepared in the absence of CTAB (729 K). Samples synthesized with CTAB show higher dielectric constants as compared to samples prepared without CTAB, while dielectric constant for all samples show decrease in value with the increase in frequency. These results imply that CTAB may act as a crystallization master, controlling the nucleation and growth of SrFe{sub 10}Al{sub 2}O{sub 19} crystal. The study delineates the scope of improving magnetic properties of ferrites without substitution of metal ions.« less
Anomalous Nernst and Hall effects in magnetized platinum and palladium
NASA Astrophysics Data System (ADS)
Guo, G. Y.; Niu, Q.; Nagaosa, N.
2014-06-01
We study the anomalous Nernst effect (ANE) and anomalous Hall effect (AHE) in proximity-induced ferromagnetic palladium and platinum which is widely used in spintronics, within the Berry phase formalism based on the relativistic band-structure calculations. We find that both the anomalous Hall (σxyA) and Nernst (αxyA) conductivities can be related to the spin Hall conductivity (σxyS) and band exchange splitting (Δex) by relations σxyA=Δex
Observations of magnetite dissolution in poorly drained soils
Grimley, D.A.; Arruda, N.K.
2007-01-01
Dissolution of strongly magnetic minerals is a common and relatively rapid phenomenon in poorly drained soils of the central United States, resulting in low magnetic susceptibility (MS). Low Eh reducing conditions are primarily responsible for magnetic mineral dissolution; a process likely mediated by iron-reducing bacteria in the presence of soil organic matter. Based on transects across drainage sequences from nine sites, natural magnetic minerals (>5 ??m) extracted from surface soil consist of 54% ?? 18% magnetite, 21% ?? 11% titanomagnetite, and 17% ?? 14% ilmenite. Magnetite and titanomagnetite dissolution, assessed by scanning electron microscopy on a 0-to-3 scale, inversely correlates with surface soil MS (r = 0.53), a proxy for soil drainage at studied transects. Altered magnetite typically displays etch pits 5 ??m) include 26% ?? 18% anthropogenic fly ash that also exhibits greater dissolution in low MS soils (r = 0.38), indicating detectable alteration can occur within 150 years in low Eh soils. Laboratory induced reduction of magnetite, titanomagnetite, and magnetic fly ash, with a citrate-bicarbonate- dithionite solution, resulted in dissolution textures similar to those of in situ soil particles. Although experiments indicate that reductive dissolution of magnetite can occur abiotically under extreme conditions, bacteria likely play an important role in the natural environment. ?? 2007 Lippincott Williams & Wilkins, Inc.
Influence of cobalt on structural and magnetic properties of nickel ferrite nanoparticles
NASA Astrophysics Data System (ADS)
Ati, Ali A.; Othaman, Zulkafli; Samavati, Alireza
2013-11-01
Improving the magnetic response of nanocrystalline nickel ferrites is the key issue in high density recording media. A series of cobalt substituted nickel ferrite nanoparticles with composition Ni(1-x)CoxFe2O4, where 0.0 ⩽ x ⩽ 1.0, are synthesized using co-precipitation method. The XRD spectra revealed the single phase spinel structure and the average sizes of nanoparticles are estimated to be 16-19 nm. These sizes are small enough to achieve the suitable signal to noise ratio in the high density recording media. The lattice parameter and coercivity shows monotonic increment with the increase of Co contents ascribed to the larger ionic radii of the cobalt ion. The specific saturation magnetization (Ms), remanent magnetization (Mr) and the coercivity (Hc) of the spinel ferrites are further improved by the substitutions of Co+2 ions. The values of Ms for NiFe2O4 and CoFe2O4 are found to be 43.92 and 78.59 emu/g, respectively and Hc are in the range of 51-778 Oe. The FTIR spectra of the spinel phase calcinated at 600 °C exhibit two prominent fundamental absorption bands in the range of 350-600 cm-1 assigned to the intrinsic stretching vibrations of the metal at the tetrahedral and octahedral sites. The role played by the Co ions in improving the structural and magnetic properties are analyzed and understood. Our simple, economic and environmental friendly preparation method may contribute towards the controlled growth of high quality ferrite nanopowders, potential candidates for recording.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Tang, W.; Wu, Y. Q.; Dennis, K. W.
2006-04-15
Effects of a TiC addition on microstructure and magnetic properties in [MRE{sub 2.2}Fe{sub 14}B]{sub (100-2x)/17.2}+Ti{sub x}C{sub x}(MRE=Nd+Y+Dy,x=1-5) ribbons, melt spun at a wheel speed of 16 m/s, were systematically studied. X-ray diffraction and differential thermal analysis data revealed that the addition of TiC improves the glass formability in the mixed rare earth alloys without Co, resulting in partially amorphous alloys. TEM observations showed that the average grain size in the as spun samples decreases from 200 to 20 nm with increasing x from 1 to 5, confirming that the addition of TiC can significantly improve microstructure. For an optimized [MRE{submore » 2}(Fe,Co){sub 14}B]{sub (100-2x)/17.2}+Ti{sub x}C{sub x} sample with x=2, spun at 25 m/s and annealed at 750 deg. C for 15 min, the room-temperature magnetic properties of H{sub cj}=11.8 kOe, M{sub r}=7.2 kGs, and (BH){sub max}=11.3 MGOe were obtained. Temperature coefficients for M{sub r} and H{sub cj} of -0.06 and -0.37%/ deg. C, respectively, also were measured in the temperature range of 27-100 deg. C. The new magnet alloy exhibits more uniform magnetic properties and a usable energy product to nearly 300 deg. C.« less
Paleomagnetic and rock magnetic investigation of an exceptionally pristine sample from Mars
NASA Astrophysics Data System (ADS)
Rochette, P.; Gattacceca, J.; Cournède, C.; Sautter, V.
2012-04-01
Unaltered samples from Mars are available as meteorites recovered right after their fall. Only 4 of them were available (the last one fell 50 yrs ago) until the recovery of a Martian meteorite fallen in Morocco in July 2010. We obtained a 1.8 g sample away from the fusion crust of this fall (named Tissint), to study its magnetic properties. Petrographic examination indicates the meteorite is an olivine-phyric shergottite, with pyrrhotite and chromite as the only identified potentially magnetic minerals. Rock magnetism is fully consistent with pyrrhotite-bearing shergottites [1], with a high coercivity of remanence (Mrs/Ms ≈0.4, Bcr of 80 mT, S ratio of -0.75, etc). Ms is about 0.15 Am2/kg, equivalent to 1 wt.% pyrrhotite. Micromagnetometric investigation should allow to identify the mineral phase responsible for remanence and solve the debate on chromite [2] versus pyrrhotite [1]. Magnetic anisotropy and NRM are directionally consistent in oriented subsamples. The meteorite shows no sign of remagnetization by magnet application (a customary practice among meteorite hunters). NRM is very hard with respect to alternating field demagnetization with a median destructive field of about 70 mT. Very low NRM/IRM derivative ratio (REM' integrated between 10 and 80 mT is about 2 10-4, the lowest ever measured in a meteorite) suggest NRM acquisition in very low ambient field (<1 µT). Moreover, the high coercivity of the NRM and the increasing REM' value with alternating field suggest that the NRM may be a shock-hardened magnetization (for instance a primary thermoremanent magnetization acquired in a crustal remanent field of a few µT, and later shocked in a similar field). Indeed this meteorite has suffered high shock pressure, as evidenced by amorphization of plagioclase and formation of numerous large melt pockets. [1] Rochette P et al. Meteorit. Planet. Sci, 40, 529-540 (2005) [2] Yu Y.J., Earth Planet. Sci. Lett. 250, 27-37 (2006)
Effect of Cobalt Concentration and Oxygen Vacancy on Magnetism of Co Doped ZnO Nanorods.
Li, Congli; Che, Ping; Sun, Changyan; Li, Wenjun
2016-03-01
Zn(1-x)Co(x)O (x = 0-0.07) single-crystalline nanorods were prepared by a modified microemulsion route. The crystalline structure, morphology, optical, and hysteresis loop at low and room temperature of as-prepared materials were characterized by XRD, TEM, PL spectra, and magnetic measurement respectively. The nanorods are 80-250 nm in diameter and about 3 μm in length. X-ray diffraction data, TEM images confirm that the materials synthesized in optimal conditions are ZnO:Co single crystalline solid solution without any impurities related to Co. The PL spectra show that the ferromagnetic samples exhibit strong Zn interstitials and oxygen vacancy emission indicating defects may stabilize ferromagnetic order in the obtained diluted magnetic semiconductors. Magnetic measurements show that the Zn(1-x)Co(x)O nanorods exist obvious ferromagnetic characteristics with T(c) above 300 K. M(s) and coercivities first increase and then decrease with dopant concentration increasing, reaching the highest for 3% doping level. The structural and magnetic properties of these samples support the hypothesis that the FM of DMS nanorods is due to a defect mediated mechanism instead of cobalt nanoclusters and carrier mediated.
NASA Astrophysics Data System (ADS)
Chavan, Apparao R.; Chilwar, R. R.; Shisode, M. V.; Hivrekar, Mahesh M.; Mande, V. K.; Jadhav, K. M.
2018-05-01
The nanocrystalline NiFe2O4 thin film has been prepared using a spray pyrolysis technique on glass substrate. The prepared thin film was characterized by using X-ray diffraction (XRD), Fourier transform Infrared spectroscopy (FTIR), and Field Emission-Scanning Electron Microscopy (FE-SEM) characterization techniques for the structural and microstructural analysis. The magnetic property was measured using vibrating sample magnetometer (VSM) at room temperature. X-ray diffraction studies show the formation of single phase spinel structure of the thin film. The octahedral and tetrahedral vibration in the sample was studied by Fourier transform infrared (FT-IR) spectra. Magnetic hysteresis loop was recorded for thin film at room temperature. At 15 kOe, saturation magnetization (Ms) was found to increase while coercivity (Hc) decreases with thickness of the NiFe2O4 thin film.
Cubic Mn2Ga Thin Films: Crossing the Spin Gap with Ruthenium
NASA Astrophysics Data System (ADS)
Kurt, H.; Rode, K.; Stamenov, P.; Venkatesan, M.; Lau, Y.-C.; Fonda, E.; Coey, J. M. D.
2014-01-01
Cubic Mn2Ga films with the half-Heusler C1b structure are grown on V (001) epitaxial films. The phase is a soft ferrimagnet, with Curie temperature TC = 225 K and magnetization Ms=280 kA m-1, equivalent to 1.65μB per formula. Adding ruthenium leads to an increase of TC up to 550 K in cubic Mn2RuxGa films with x = 0.33 and a collapse of the net magnetization. The anomalous Hall effect changes sign at x = 0.5, where the sign of the magnetization changes and the magnetic easy direction flips from in plane to perpendicular to the film. The Mn2Ru0.5Ga compound with a valence electron count of 21 is identified as a zero-moment ferrimagnet with high spin polarization, which shows evidence of half-metallicity.
Chen, Di; Zheng, Hao-Bo; Huang, Yun-Qing; Hu, Yu-Ning; Yu, Qiong-Wei; Yuan, Bi-Feng; Feng, Yu-Qi
2015-08-21
Ambient ionization techniques show good potential in rapid analysis of target compounds. However, a direct application of these ambient ionization techniques for the determination of analytes in a complex matrix is difficult due to the matrix interference and ion suppression. To resolve this problem, here we developed a strategy by coupling magnetic solid phase extraction (MSPE) with desorption corona beam ionization (DCBI)-mass spectrometry (MS). As a proof of concept, the pyrrole-coated Fe3O4 magnetic nanoparticles (Fe3O4@Ppy) were prepared and used for the extraction of antidepressants. After extraction, the Fe3O4@Ppy with trapped antidepressants was then directly subjected to DCBI-MS analysis with the aid of a homemade magnetic glass capillary. As the MSPE process is rapid and the direct DCBI-MS analysis does not need solvent desorption or chromatographic separation processes, the overall analysis can be completed within 3 min. The proposed MSPE-DCBI-MS method was then successfully used to determine antidepressants in human urine and plasma. The calibration curves were obtained in the range of 0.005-0.5 μg mL(-1) for urine and 0.02-1 μg mL(-1) for plasma with reasonable linearity (R(2) > 0.951). The limits of detection of three antidepressants were in the range of 0.2-1 ng mL(-1) for urine and 2-5 ng mL(-1) for plasma. Acceptable reproducibility for rapid analysis was achieved with relative standard deviations less than 19.1% and the relative recoveries were 85.2-118.7%. Taken together, the developed MSPE-DCBI-MS strategy offers a powerful capacity for rapid analysis of target compounds in a complex matrix, which would greatly expand the applications of ambient ionization techniques with plentiful magnetic sorbents.
NASA Astrophysics Data System (ADS)
Ichida, Yoshio; Sato, Ryunosuke; Morimoto, Yoshitaka; Ohsawa, Yoshiteru; Fredj, Nabil Ben
In this paper, we describe the formation mechanism of a finished surface in ultrahigh-speed grinding under a peripheral wheel speed higher than 200m/s. Grinding experiments using a grinding machine tool equipped with an active magnetic bearing spindle have been conducted over a range of grinding speeds from 60 to 300m/s. Moreover, grinding tests for producing some individual grooves using a grinding tool with multiple cBN grit have been carried out to clarify the effects of grinding speed on the side swelling formed along both sides of the grinding grooves. From the results of these experiments, we have confirmed that the roughness of the ground surface decreases with an increase in grinding speed, and this decrease is mainly due to the reduction of the swelling ratio with increasing grinding speed.
NASA Astrophysics Data System (ADS)
Chen, Daming; Chen, Zhuo; Wang, Guijuan; Chen, Yong; Li, Yuanxun; Liu, Yingli
2017-12-01
The microstructure, magnetic and millimeter-wave properties of high oriented barium hexaferrite (BaAlxFe12-xO19) thin films with Al doping level x from 0 to 2 are reported. The films were grown on Pt/TiO2/SiO2/Si substrate by Sol-gel method. It is found that with increasing x from 0 to 2 the hexagonal grain disappear, together with Curie temperature dropped from 449 °C to 332 °C and saturated magnetization (4πMs) decreased from 3.8 kG to 1.9 kG, it is attributed to the fact that the Fe ions were substituted by non-magnetic Al ions, leading to the Fe3+-O-Fe3+ super-exchange interaction became weak. The ferromagnetic resonance (FMR) measurement showed that the FMR linewidths is as low as 113 Oe @ 58 GHz, and the FMR frequency shifted to higher frequency range when increasing Al doping level. These result offer the potential application of barium ferrite thin films in tunable millimeter wave devices such as filter, circulator and isolator.
NASA Astrophysics Data System (ADS)
Asvini, V.; Saravanan, G.; Kalaiezhily, R. K.; Raja, M. Manivel; Ravichandran, K.
2018-04-01
Fe2CoSi based Heusler alloy thin films were deposited on Si (111) wafer (substrate) of varying thickness using ultra high vacuum DC magnetron sputtering. The structural behavior was observed and found to be hold the L21 structure. The deposited thin films were characterized magnetic properties using vibrating sample magnetometer; the result shows a very high saturated magnetization (Ms), lowest coercivity (Hc), high curie transition temperature (Tc) and low hysteresis loss. Thin film thickness of 75 nm Fe2CoSi sample maintained at substrate temperature 450°C shows the lowest coercivity (Hc=7 Oe). In general, Fe2CoSi Heusler alloys curie transition temperature is very high, due to strong exchange interaction between the Fe and Co atoms. The substrate temperature was kept constant at 450°C for varying thickness (e.g. 5, 20, 50, 75 and 100 nm) of thin film sample. The 75 nm thickness thin film sample shows well crystallanity and good magnetic properties, further squareness ratio in B-H loop increases with the increase in film thickness.
NASA Technical Reports Server (NTRS)
Newell, R. E.
1974-01-01
Sudden commencement events are examined in terms of available auroral-zone and low-latitude magnetic field, data, interplanetary plasma and magnetic field data, and magnetospheric electron flux and magnetic field data from the geostationary satellite ATS 1.
Grimley, D.A.; Arruda, N.K.; Bramstedt, M.W.
2004-01-01
Standard field indicators, currently used for hydric soil delineations [USDA-NRCS, 1998. Field indicators of hydric soils in the United States, Version 4.0. In: G.W. Hurt et al. (Ed.), United States Department of Agriculture-NRCS, Fort Worth, TX], are useful, but in some cases, they can be subjective, difficult to recognize, or time consuming to assess. Magnetic susceptibility (MS) measurements, acquired rapidly in the field with a portable meter, have great potential to help soil scientists delineate and map areas of hydric soils more precisely and objectively. At five sites in Illinois (from 5 to 15 ha in area) with contrasting soil types and glacial histories, the MS values of surface soils were measured along transects, and afterwards mapped and contoured. The MS values were found to be consistently higher in well-drained soils and lower in hydric soils, reflecting anaerobic deterioration of both detrital magnetite and soil-formed ferrimagnetics. At each site, volumetric MS values were statistically compared to field indicators to determine a critical MS value for hydric soil delineation. Such critical values range between 22??10-5 and 33??10-5 SI in silty loessal or alluvial soils in Illinois, but are as high as 61??10-5 SI at a site with fine sandy soil. A higher magnetite content and slower dissolution rate in sandy soils may explain the difference. Among sites with silty parent material, the lowest critical value (22??10-5 SI) occurs in soil with low pH (4.5-5.5) since acidic conditions are less favorable to ferrimagnetic mineral neoformation and enhance magnetite dissolution. Because of their sensitivity to parent material properties and soil pH, critical MS values must be determined on a site specific basis. The MS of studied soil samples (0-5 cm depth) is mainly controlled by neoformed ultrafine ferrimagnetics and detrital magnetite concentrations, with a minor contribution from anthropogenic fly ash. Neoformed ferrimagnetics are present in all samples but, based on high ??FD% (???5% to 10%), are most prevalent in high pH Mollisols of northeastern Illinois. Scanning electron microscope images display significantly more detrital magnetite alteration in hydric soils, substantiating that reductive dissolution of magnetite (aided by microorganisms) is a primary cause for lower MS. Fly ash comprises 8-50% of the >5 ??m strongly magnetic particles and typically accounts for 5-15% of the total MS signal. The proportion of fly ash in >5 ??m strongly magnetic fractions is greater in hydric soils because of lower natural magnetite contents, possibly combined with historical topsoil accumulation in lower landscapes. Magnetic fly ash particles are also more altered in low MS soils, implying that significant magnetite dissolution can occur in less than 150 years. ?? 2004 Elsevier B.V. All rights reserved.
Ogrinc, N; Kosir, I J; Spangenberg, J E; Kidric, J
2003-06-01
This review covers two important techniques, high resolution nuclear magnetic resonance (NMR) spectroscopy and mass spectrometry (MS), used to characterize food products and detect possible adulteration of wine, fruit juices, and olive oil, all important products of the Mediterranean Basin. Emphasis is placed on the complementary use of SNIF-NMR (site-specific natural isotopic fractionation nuclear magnetic resonance) and IRMS (isotope-ratio mass spectrometry) in association with chemometric methods for detecting the adulteration.
NASA Astrophysics Data System (ADS)
Li, Yong-Chao; Wu, Jun; Pan, Hai-Yang; Wang, Jue; Wang, Guang-Hou; Liu, Jun-Ming; Wan, Jian-Guo
2018-05-01
Mn:ZnO/Pb(Zr0.52Ti0.48)O3 (PZT) heterostructured films have been prepared on Pt/Ti/SiO2/Si wafers by a sol-gel process. Nonvolatile and reversible manipulation of the magnetism and resistance by electric fields has been realized. Compared with the saturation magnetic moment (Ms) in the +3.0 V case, the modulation gain of Ms can reach 270% in the -3.0 V case at room temperature. The resistance change is attributed to the interfacial potential barrier height variation and the formation of an accumulation (or depletion) layer at the Mn:ZnO/PZT interface, which can be regulated by the ferroelectric polarization direction. The magnetism of Mn:ZnO originates from bound magnetic polarons. The mobile carrier variation in Mn:ZnO, owing to interfacial polarization coupling and the ferroelectric field effect, enables the electric manipulation of the magnetism in the Mn:ZnO/PZT heterostructured films. This work presents an effective method for modulating the magnetism of magnetic semiconductors and provides a promising avenue for multifunctional devices with both electric and magnetic functionalities.
Shi, Shu Yun; Zhang, Yu Ping; Zhou, Hong Hao; Huang, Ke Long; Jiang, Xin Yu
2010-01-01
An online rapid screening method, the high-performance liquid chromatography (HPLC)-diode array detector (DAD)-radical scavenging detection (RSD)-electrospray ionization (ESI)-mass spectroscopy (MS)/MS system, was developed for the screening and identification of radical scavengers from Neo-Taraxacum siphonanthum, a new species found in China in 1989. For further characterization, the target compounds were isolated by silica column chromatography, preparative high-performance liquid chromatography (HPLC), HSCCC, and Sephadex LH-20 column chromatography and elucidated on the basis of ultraviolet (UV), ESI-MS/MS, and nuclear magnetic resonance (NMR) spectroscopy, as well as the chemical analysis. Eighteen antioxidative polyphenols (5 caffeic acid derivatives and 13 flavonoid derivatives) were characterized from Neo-T. siphonanthum. The distribution of all compounds was discussed in a chemosystematic context, which suggested that the genera Neo-Taraxacum and Taraxacum might relate chemosystematically.
Rational synthesis of zerovalent iron/bamboo charcoal composites with high saturation magnetization
Mingshan Wu; Jianfeng Ma; Zhiyong Cai; Genlin Tian; Shumin Yang; Youhong Wang; Xing' e Liu
2015-01-01
The synthesis of magnetic biochar composites is a major new research area in advanced materials sciences. A series of magnetic bamboo charcoal composites (MBC800, MBC1000 and MBC1200) with high saturation magnetization (Ms) was fabricated in this work by mixing bamboo charcoal powder with an aqueous ferric chloride solution and subsequently...
He, Man; Huang, Lijin; Zhao, Bingshan; Chen, Beibei; Hu, Bin
2017-06-22
For the determination of trace elements and their species in various real samples by inductively coupled plasma mass spectrometry (ICP-MS), solid phase extraction (SPE) is a commonly used sample pretreatment technique to remove complex matrix, pre-concentrate target analytes and make the samples suitable for subsequent sample introduction and measurements. The sensitivity, selectivity/anti-interference ability, sample throughput and application potential of the methodology of SPE-ICP-MS are greatly dependent on SPE adsorbents. This article presents a general overview of the use of advanced functional materials (AFMs) in SPE for ICP-MS determination of trace elements and their species in the past decade. Herein the AFMs refer to the materials featuring with high adsorption capacity, good selectivity, fast adsorption/desorption dynamics and satisfying special requirements in real sample analysis, including nanometer-sized materials, porous materials, ion imprinting polymers, restricted access materials and magnetic materials. Carbon/silica/metal/metal oxide nanometer-sized adsorbents with high surface area and plenty of adsorption sites exhibit high adsorption capacity, and porous adsorbents would provide more adsorption sites and faster adsorption dynamics. The selectivity of the materials for target elements/species can be improved by using physical/chemical modification, ion imprinting and restricted accessed technique. Magnetic adsorbents in conventional batch operation offer unique magnetic response and high surface area-volume ratio which provide a very easy phase separation, greater extraction capacity and efficiency over conventional adsorbents, and chip-based magnetic SPE provides a versatile platform for special requirement (e.g. cell analysis). The performance of these adsorbents for the determination of trace elements and their species in different matrices by ICP-MS is discussed in detail, along with perspectives and possible challenges in the future development. Copyright © 2017 Elsevier B.V. All rights reserved.
Magnetic tracing of material from a point source in a river system
NASA Astrophysics Data System (ADS)
Appel, Erwin; Liu, Zhao; Mülller, Christina; Frančišković-Bilinski, Stanislav; Rösler, Wolfgang; Zhang, Qi
2017-04-01
In fluvial environment, the mechanism of transport, distribution, and fate of contaminants, and the resulting distribution patterns are complex but only limited studied. A case in Croatia where highly magnetic coal slag was dumped into a river for more than one century (1884-1994) offers an ideal target for studying principles of how to capture the magnetic record of environmental pollution in a river system originating from a well-defined point source. Downstream transport of the coal slag can be roughly recognized by simple sampling of river sediments, but this approach is poorly significant due to the extremely variable magnetic properties caused by hydrodynamic sorting. We suggest applying variogram analyses in river traverses to obtain more reliable values of magnetic concentration, and combining these results with modeling of river bottom magnetic anomalies in order to estimate the amount of coal slag at certain positions. A major focus of this presentation is the translocation of coal slag material to the riverbanks by flooding, i.e. the possible identification of flood affected areas and the discrimination of different flood events. Surface magnetic susceptibility (MS) mapping clearly outlines the extent of flooded areas, and repeated measurements after one year reveal the reach of two recent smaller floods within this period by spatial delineation of strong positive and negative changes of MS values. To identify older flood signatures, dense grids of vertical MS profiles were analyzed at two riverbank areas in two different ways. First, by determining differences between depth horizons at the measurement points, and second, by contouring the vertical MS profiles as a function of the distance to the river (area with flat riverbank topography) and as a function of terrain elevation (area with oblique riverbank). Single flood events cannot be discriminated, but the second approach allows to approximately identify the extent of major historical floods which were interrupted by longer periods of less intensive flooding. The so far obtained results suggest that a more detailed magnetic study of this 'Croatian case' can contribute to better understanding of material displacement in a river system and how to perform significant sampling of river sediments.
Grimley, D.A.; Wang, J.-S.; Liebert, D.A.; Dawson, J.O.
2008-01-01
Flooded, saturated, or poorly drained soils are commonly anaerobic, leading to microbially induced magnetite/maghemite dissolution and decreased soil magnetic susceptibility (MS). Thus, MS is considerably higher in well-drained soils (MS typically 40-80 ?? 10-5 standard international [SI]) compared to poorly drained soils (MS typically 10-25 ?? 10-5 SI) in Illinois, other soil-forming factors being equal. Following calibration to standard soil probings, MS values can be used to rapidly and precisely delineate hydric from nonhydric soils in areas with relatively uniform parent material. Furthermore, soil MS has a moderate to strong association with individual tree species' distribution across soil moisture regimes, correlating inversely with independently reported rankings of a tree species' flood tolerance. Soil MS mapping can thus provide a simple, rapid, and quantitative means for precisely guiding reforestation with respect to plant species' adaptations to soil drainage classes. For instance, in native woodlands of east-central Illinois, Quercus alba , Prunus serotina, and Liriodendron tulipifera predominantly occur in moderately well-drained soils (MS 40-60 ?? 10-5 SI), whereas Acer saccharinum, Carya laciniosa, and Fraxinus pennsylvanica predominantly occur in poorly drained soils (MS <20 ?? 10-5 SI). Using a similar method, an MS contour map was used to guide restoration of mesic, wet mesic, and wet prairie species to pre-settlement distributions at Meadowbrook Park (Urbana, IL, U.S.A.). Through use of soil MS maps calibrated to soil drainage class and native vegetation occurrence, restoration efforts can be conducted more successfully and species distributions more accurately reconstructed at the microecosystem level. ?? 2008 Society for Ecological Restoration International.
Bizjak, Neli; Osredkar, Damjan; Perković Benedik, Mirjana; Šega Jazbec, Saša
2017-11-01
Although multiple sclerosis usually affects young adults, paediatric-onset multiple sclerosis (pMS) is increasingly recognized in the past ten years. The aim of the present study was to evaluate the incidence of pMS in Slovenia and to characterize the clinical, laboratory and neuroradiological characteristics of pMS at the disease onset. We performed a national retrospective descriptive study including all patients diagnosed with pMS between January 1992 and June 2017. We reviewed data of all patients younger than 18 years at the first demyelinating event. The estimated incidence of pMS was 0.66/100,000 children per year. We included 61 patients (77% were female) with a median age at diagnosis of 16.3 years. In 4 patients, onset of pMS was before the age of 12 years old (childhood-onset pMS). Relapsing-remitting multiple sclerosis was most prevalent, with only 2 patients presenting a primary progressive pMS. Polysymptomatic pMS was found at onset in 59% of patients and monosymptomatic in 41%. In the cerebrospinal fluid study, 88% of patients had positive oligoclonal bands. Brain magnetic resonance imaging studies showed a predominant supratentorial involvement (100% of patients). The clinical pattern of pMS in our cohort of patients was characterized by polysymptomatic presentation and predominantly sensory symptoms at onset, developing a relapsing-remitting pMS pattern. It is important to gather more information about the incidence of pMS and its initial presentation and clinical course to improve early recognition and appropriate initiation of immunomodulatory treatment. Copyright © 2017 Elsevier B.V. All rights reserved.
Cerebral white matter blood flow and energy metabolism in multiple sclerosis.
Steen, Christel; D'haeseleer, Miguel; Hoogduin, Johannes M; Fierens, Yves; Cambron, Melissa; Mostert, Jop P; Heersema, Dorothea J; Koch, Marcus W; De Keyser, Jacques
2013-09-01
Cerebral blood flow (CBF) is reduced in normal-appearing white matter (NAWM) of subjects with multiple sclerosis (MS), but the underlying mechanism is unknown. The objective of this article is to assess the relationship between reduced NAWM CBF and both axonal mitochondrial metabolism and astrocytic phosphocreatine (PCr) metabolism. Ten healthy controls and 25 MS subjects were studied with 3 Tesla magnetic resonance imaging. CBF was measured using pseudo-continuous arterial spin labeling. N-acetylaspartate/creatine (NAA/Cr) ratios (axonal mitochondrial metabolism) were obtained using (1)H-MR spectroscopy and PCr/β-ATP ratios using (31)P-MR spectroscopy. In centrum semiovale NAWM, we assessed correlations between CBF and both NAA/Cr and PCr/β-ATP ratios. Subjects with MS had a widespread reduction in CBF of NAWM (centrum semiovale, periventricular, frontal and occipital), and gray matter (frontoparietal cortex and thalamus). Compared to controls, NAA/Cr in NAWM of the centrum semiovale of MS subjects was decreased, whereas PCr/β-ATP was increased. We found no correlations between CBF and PCr/β-ATP. CBF and NAA/Cr correlated in controls (p = 0.02), but not in MS subjects (p = 0.68). Our results suggest that in MS patients there is no relationship between reduced CBF in NAWM and impaired axonal mitochondrial metabolism or astrocytic PCr metabolism.
40-Tesla pulsed-field cryomagnet for single crystal neutron diffraction
NASA Astrophysics Data System (ADS)
Duc, F.; Tonon, X.; Billette, J.; Rollet, B.; Knafo, W.; Bourdarot, F.; Béard, J.; Mantegazza, F.; Longuet, B.; Lorenzo, J. E.; Lelièvre-Berna, E.; Frings, P.; Regnault, L.-P.
2018-05-01
We present the first long-duration and high duty cycle 40-T pulsed-field cryomagnet addressed to single crystal neutron diffraction experiments at temperatures down to 2 K. The magnet produces a horizontal field in a bi-conical geometry, ±15° and ±30° upstream and downstream of the sample, respectively. Using a 1.15 MJ mobile generator, magnetic field pulses of 100 ms length are generated in the magnet, with a rise time of 23 ms and a repetition rate of 6-7 pulses per hour at 40 T. The setup was validated for neutron diffraction on the CEA-CRG three-axis spectrometer IN22 at the Institut Laue Langevin.
Rossi, Silvia; Motta, Caterina; Studer, Valeria; Monteleone, Fabrizia; De Chiara, Valentina; Buttari, Fabio; Barbieri, Francesca; Bernardi, Giorgio; Battistini, Luca; Cutter, Gary; Stüve, Olaf; Salvetti, Marco; Centonze, Diego
2013-01-01
Multiple sclerosis (MS) patients discontinuing natalizumab treatment are at risk of disease reactivation. No clinical or surrogate parameters exist to identify patients at risk of post-natalizumab MS reactivation. To determine the role of natalizumab-induced lymphocytosis and of Akt polymorphisms in disease reactivation after natalizumab discontinuation. Peripheral leukocyte count and composition were monitored in 93 MS patients during natalizumab treatment, and in 56 of these subjects who discontinued the treatment. Genetic variants of the anti-apoptotic protein Akt were determined in all subjects because natalizumab modulates the apoptotic pathway and lymphocyte survival is regulated by the apoptotic cascade. Natalizumab-induced peripheral lymphocytosis protected from post-natalizumab MS reactivation. Subjects who relapsed or had magnetic resonance imaging (MRI) worsening after treatment cessation, in fact, had milder peripheral lymphocyte increases during the treatment, largely caused by less marked T cell increase. Furthermore, subjects carrying a variant of the gene coding for Akt associated with reduced anti-apoptotic efficiency (rs2498804T) had lower lymphocytosis and higher risk of disease reactivation. This study identified one functionally meaningful genetic variant within the Akt signaling pathway that is associated with both lymphocyte count and composition alterations during natalizumab treatment, and with the risk of disease reactivation after natalizumab discontinuation.
Mori, Yuki; Murakami, Masaaki; Arima, Yasunobu; Zhu, Dasong; Terayama, Yasuo; Komai, Yutaka; Nakatsuji, Yuji; Kamimura, Daisuke; Yoshioka, Yoshichika
2014-02-01
Magnetic resonance imaging (MRI) is widely employed for the diagnosis of multiple sclerosis (MS). However, sometimes, the lesions found by MRI do not correlate with the neurological impairments observed in MS patients. We recently showed autoreactive T cells accumulate in the fifth lumbar cord (L5) to pass the blood-brain barrier and cause inflammation in the central nervous system of experimental autoimmune encephalomyelitis (EAE) mice, an MS model. We here investigated this early event using ultrahigh-field MRI. T2-weighted image signals, which conform to the water content, increased in L4 and L5 during the development of EAE. At the same time, the sizes of L4 and L5 changed. Moreover, angiographic images of MRI showed branch positions of the blood vessels in the lower lumbar cords were significantly altered. Interestingly, EAE mice showed occluded and thickened vessels, particularly during the peak phase, followed by reperfusion in the remission phase. Additionally, demyelination regions of some MS patients had increased lactic acid content, suggesting the presence of ischemic events. These results suggest that inflammation-mediated alterations in the lower lumbar cord change the homeostasis of the spinal cord and demonstrate that ultrahigh-field MRI enables the detection of previously invisible pathological alterations in EAE.
Overview and diagnosis of multiple sclerosis.
Hunter, Samuel F
2016-06-01
Multiple sclerosis (MS), a chronic inflammatory disease of unknown etiology, involves an immunemediated attack of the central nervous system (CNS) that produces demyelination and axonal/neuronal damage, resulting in characteristic multifocal lesions apparent on magnetic resonance imaging and a variety of neurologic manifestations. The disease pathology is characterized by multifocal lesions within the CNS, in both the white matter and gray matter, with perivenular inflammatory cell infiltrates, demyelination, axonal transection, neuronal degeneration, and gliosis. MS pathogenesis is complex, as it involves both T- and B-cell mechanisms and is heterogeneous in presentation. Relatively recently, the historical 4 core clinical categories of MS were revised in an effort to improve characterization of the clinical course, better identify where a given patient is positioned in the disease spectrum, and to guide clinical studies. In young and middle-aged adults, MS is one of the most common contributors to neurologic disability, and it exerts detrimental effects on a patient's productivity and health-related quality of life. Typically, patients with MS have a long life span, although healthcare utilization increases over time. As a consequence, the disease places a substantial burden on patients and their caregivers/families, as well as employers, the healthcare system, and society.
Levesque, Ives; Sled, John G; Narayanan, Sridar; Santos, A Carlos; Brass, Steven D; Francis, Simon J; Arnold, Douglas L; Pike, G Bruce
2005-02-01
To use quantitative magnetization transfer imaging (qMTI) in an investigation of T1-weighted hypointensity observed in clinical magnetic resonance imaging (MRI) scans of multiple sclerosis (MS) patients, which has previously been proposed as a more specific indicator of tissue damage than the more commonly detected T2 hyperintensity. A cross-sectional study of 10 MS patients was performed using qMTI. A total of 60 MTI measurements were collected in each patient at a resolution of 2 x 2 x 7 mm, over a range of saturation pulses. The observed T1 and T2 were also measured. qMT model parameters were estimated using a voxel-by-voxel fit. A total of 65 T2-hyperintense lesions were identified; 53 were also T1 hypointense. In these black holes, the qMTI-derived semisolid pool fraction F correlated negatively with T(1,obs) (r2 = 0.76; P < 0.0001). The water pool absolute size (PDf) showed a weaker correlation with T(1,obs) (positive, r2 = 0.53; P < 0.0001). The magnetization transfer ratio (MTR) showed a similarly strong correlation with F and a weaker correlation with PDf (r2 = 0.18; P < 0.04). T1 increases in chronic black holes strongly correlated with the decline in semisolid pool size, and somewhat less to the confounding effect of edema. MTR was less sensitive than T(1,obs) to liquid pool changes associated with edema. (c) 2005 Wiley-Liss, Inc.
Zhang, Yu-Zhen; Zhang, Jia-Wei; Wang, Chong-Zhi; Zhou, Lian-Di; Zhang, Qi-Hui; Yuan, Chun-Su
2018-01-24
In this work, a modified pretreatment method using magnetic molecularly imprinted polymers (MMIPs) was successfully applied to study the metabolites of an important botanical with ultraperformance liquid chromatography/quadrupole time-of-flight mass spectrometry (UPLC-Q-TOF-MS). The MMIPs for glucoside-specific adsorption was used to identify metabolites of Pulsatilla chinensis in rat feces. Polymers were prepared by using Fe 3 O 4 nanoparticles as the supporting matrix, d-glucose as fragment template, and dopamine as the functional monomer and cross-linker. Results showed that MMIPs exhibited excellent extraction performance, large adsorption capacity (5.65 mg/g), fast kinetics (60 min), and magnetic separation. Furthermore, the MMIPs coupled with UPLC-Q-TOF-MS were successfully utilized for the identification of 17 compounds including 15 metabolites from the Pulsatilla saponin metabolic pool. This study provides a reliable protocol for the separation and identification of saponin metabolites in a complex biological sample, including those from herbal medicines.
Magnetoimpedance studies on urine treated Co66Ni7Si7B20 ribbons
NASA Astrophysics Data System (ADS)
Kotagiri, Ganesh; Markandeyulu, G.; Doble, Mukesh; Nandakumar, V.
2015-11-01
Magnetoimpedance (MI) response of Co66Ni7Si7B20 ribbons treated with artificial urine with protein bovine serum albumin (BSA), artificial urine without protein BSA and healthy male urine was studied as a function of time of incubation. The maximum MI [(MI)m] values of the ribbons treated with artificial urine without protein (RTAU) after 3 h, 6 h, 12 h and 24 h of incubation are 30% (at 4 MHz), 15% (at 5 MHz), 14% (at 10 MHz) and 8% (at 13 MHz) respectively. On the other hand, the respective (MI)m values of the ribbons treated with artificial urine with protein (RTAUP) are 33% (at 4 MHz), 25% (at 5 MHz), 20% (at 8 MHz) and 15% (12 MHz). However (MI)m values of the ribbons treated with healthy male urine (RTHMU) after 4 h, 5 h, 10 h and 15 h of incubation are 71% (at 3 MHz), 57% (at 3 MHz), 25% (at 6 MHz) and 25% (at 5 MHz), respectively. The saturation magnetization (Ms) values of RTAU after 3 h, 6 h, 12 h and 24 h of incubation are 71 emu/g, 65 emu/g, 63 emu/g and 60 emu/g respectively whereas, the respective Ms values of RTAUP are 73 emu/g, 69 emu/g, 67 emu/g and 64 emu/g. The Ms values of RTHMU after 4 h, 5 h, 10 h and 15 h of incubation are 96 emu/g, 90 emu/g, 75 emu/g and 75 emu/g respectively. The decrease in Ms and (MI)m values in RTAU and RTAUP compared to as-quenched ribbon is related to the amounts of various elements etched out from the ribbons and increased surface roughness. The Ms and (MI)m values of RTHMU are seen to have increased after 4 h and 5 h of incubation, due to strain relaxation through removal of strain developed during rapid quenching of the ribbons. On the other hand, the Ms and (MI)m values of RTHMU after 10 h and 15 h have decreased due to deterioration of the surface of the ribbons and thus, increase in magnetic (surface) anisotropy. The decrease in (MI)m and MS of RTAU with the time of incubation are more rapid compared to that of RTAUP, probably due to the larger surface anisotropy due to rapid deterioration of the surface of the RTAU than in RTAUP. Asymmetry in MI profiles of RTAU, RTAUP and RTHMU was observed and is attributed to the non-uniform etching of the surface of the ribbons leading to pinning of the domain wall motion.
Resting State Brain Entropy Alterations in Relapsing Remitting Multiple Sclerosis.
Zhou, Fuqing; Zhuang, Ying; Gong, Honghan; Zhan, Jie; Grossman, Murray; Wang, Ze
2016-01-01
Brain entropy (BEN) mapping provides a novel approach to characterize brain temporal dynamics, a key feature of human brain. Using resting state functional magnetic resonance imaging (rsfMRI), reliable and spatially distributed BEN patterns have been identified in normal brain, suggesting a potential use in clinical populations since temporal brain dynamics and entropy may be altered in disease conditions. The purpose of this study was to characterize BEN in multiple sclerosis (MS), a neurodegenerative disease that affects millions of people. Since currently there is no cure for MS, developing treatment or medication that can slow down its progression represents a high research priority, for which validating a brain marker sensitive to disease and the related functional impairments is essential. Because MS can start long time before any measurable symptoms and structural deficits, assessing the dynamic brain activity and correspondingly BEN may provide a critical way to study MS and its progression. Because BEN is new to MS, we aimed to assess BEN alterations in the relapsing-remitting MS (RRMS) patients using a patient versus control design, to examine the correlation of BEN to clinical measurements, and to check the correlation of BEN to structural brain measures which have been more often used in MS studies. As compared to controls, RRMS patients showed increased BEN in motor areas, executive control area, spatial coordinating area, and memory system. Increased BEN was related to greater disease severity as measured by the expanded disability status scale (EDSS) and greater tissue damage as indicated by the mean diffusivity. Patients also showed decreased BEN in other places, which was associated with less disability or fatigue, indicating a disease-related BEN re-distribution. Our results suggest BEN as a novel and useful tool for characterizing RRMS.
NASA Technical Reports Server (NTRS)
Jennings, Anne E.
1993-01-01
The goals of the marine geology part of WAIS include reconstructing the chronology and areal extent of ice-sheet fluctuations and understanding the climatic and oceanographic influences on ice-sheet history. As an initial step toward attaining these goals, down-core volume magnetic susceptibility (MS) logs of piston cores from three N-S transects in the western Ross Sea are compared. The core transects are within separate petrographic provinces based on analyses of till composition. The provinces are thought to reflect the previous locations of ice streams on the shelf during the last glaciation. Magnetic susceptibility is a function of magnetic mineral composition, sediment texture, and sediment density. It is applied in the western Ross Sea for two purposes: (1) to determine whether MS data differentiates the three transects (i.e., flow lines), and thus can be used to make paleodrainage reconstructions of the late Wisconsinan ice sheet; and (2) to determine whether the MS data can aid in distinguishing basal till diamictons from diamictons of glacial-marine origin and thus, aid paleoenvironmental interpretations. A comparison of the combined data of cores in each transect is presented.
NASA Astrophysics Data System (ADS)
Iwahashi, Masakuni; Koyama, Yohei; Hyodo, Akira; Hayami, Takehito; Ueno, Shoogo; Iramina, Keiji
2009-04-01
To investigate the functional connectivity, the evoked potentials by stimulating at the motor cortex, the posterior parietal cortex, and the cerebellum by transcranial magnetic stimulation (TMS) were measured. It is difficult to measure the evoked electroencephalograph (EEG) by the magnetic stimulation because of the large artifact induced by the magnetic pulse. We used an EEG measurement system with sample-and-hold circuit and an independent component analysis to eliminate the electromagnetic interaction emitted from TMS. It was possible to measure EEG signals from all electrodes over the head within 10 ms after applying the TMS. When the motor area was stimulated by TMS, the spread of evoked electrical activity to the contralateral hemisphere was observed at 20 ms after stimulation. However, when the posterior parietal cortex was stimulated, the evoked electrical activity to the contralateral hemisphere was not observed. When the cerebellum was stimulated, the cortical activity propagated from the stimulated point to the frontal area and the contralateral hemisphere at around 20 ms after stimulation. These results suggest that the motor area has a strong interhemispheric connection and the posterior parietal cortex has no interhemispheric connection.
NASA Astrophysics Data System (ADS)
Elrouby, Mahmoud; Abdel-Mawgoud, A. M.; El-Rahman, Rehab Abd
2017-11-01
This work is devoted to the synthesis of magnetic iron oxides nanoparticles with very high saturation magnetization to be qualified for supercapacitor applications using, a simple electrodeposition technique. It is found that the electrochemical reduction process depends on concentration, temperature, deposition potential and the scan rate of potential. The nature of electrodeposition process has been characterized via voltammetric and chronoamperometric techniques. The morphology of the electrodeposits has been investigated using scanning electron microscopy (SEM) and transmission electron microscopy (TEM). The structure and phase content of these investigated electrodeposits have been examined and calculated. The obtained iron oxides show a high saturation magnetization (Ms) of about 229 emu g-1. The data exhibited a relation between Ms of electrodeposited iron oxide and specific capacitance. This relation exhibits that the highest Ms value of electrodeposited iron oxides gives also highest specific capacitance of about 725 Fg-1. Moreover, the electrodeposited iron oxides exhibit a very good stability. The new characteristics of the electro synthesized iron oxides at our optimized conditions, strongly qualify them as a valuable material for high-performance supercapacitor applications.
A retractable electron emitter for the creation of unperturbed pure electron plasmas.
Berkery, John W; Pedersen, Thomas Sunn; Sampedro, Luis
2007-01-01
A retractable electron emitter has been constructed for the creation of unperturbed pure electron plasmas on magnetic surfaces in the Columbia Non-neutral Torus stellarator. The previous method of electron emission using emitters mounted on stationary rods limited the confinement time to 20 ms. A pneumatically driven system that can retract from the magnetic axis to the last closed flux surface in less than 20 ms while filling the surfaces with electrons was designed. The motion of the retractable emitter was modeled with a system of dynamical equations. The measured position versus time of the emitter agrees well with the model and the fastest axis-to-edge retraction was measured to be 20 ms with 40 psig helium gas driving the pneumatic piston.
Magnetic susceptibility for use in delineating hydric soils
Grimley, D.A.; Vepraskas, M.J.
2000-01-01
Field indicators are used to identify hydric soil boundaries and to delineate wetlands. The most common field indicators may not be seen in some soils with thick, dark, mollic epipedons, and do not form in Fe-poor soils. This study evaluated magnetic susceptibility (MS) meter as a field tool to determine hydric soil boundaries. Five Mollisoldominated sites formed in glacial deposits in Illinois were evaluated along with one Ultisol-dominated site formed in Coastal Plain sediments of North Carolina. Measurements of volumetric MS were made along transects at each site that extended from wetland into upland areas. One created wetland was evaluated. Field indicators were used to identify the hydric soils. Results showed that volumetric MS values were significantly (P 0.15) differences in MS were found for Coastal Plain hydric and nonhydric soils where MS values were low (<10 ?? 10-5 SI). Critical MS values that separated hydric and nonhydric soils varied between 20 ?? 10-5 and 30 ?? 10-5 SI for the loessal soils evaluated in Illinois. Such critical values will have to be determined on site using field indicators until specific values can be defined for hydric soils within a given parent material. With a critical MS value in hand, a wetland delineator can make MS measurements along transects perpendicular to the envisioned hydric soil boundary to quickly and quantitatively identify it.
... diagnosis or provide additional evidence if it’s necessary. Magnetic Resonance Imaging (MRI) Diagnostic tool that currently offers the most ... Out Learn More Evoked Potentials (EP) Learn More Magnetic Resonance Imaging (MRI) Learn More Cerebrospinal Fluid (CSF) Learn More ...
Sparbier, Katrin; Asperger, Arndt; Resemann, Anja; Kessler, Irina; Koch, Sonja; Wenzel, Thomas; Stein, Günter; Vorwerg, Lars; Suckau, Detlev; Kostrzewa, Markus
2007-01-01
Comprehensive proteomic analyses require efficient and selective pre-fractionation to facilitate analysis of post-translationally modified peptides and proteins, and automated analysis workflows enabling the detection, identification, and structural characterization of the corresponding peptide modifications. Human serum contains a high number of glycoproteins, comprising several orders of magnitude in concentration. Thereby, isolation and subsequent identification of low-abundant glycoproteins from serum is a challenging task. selective capturing of glycopeptides and -proteins was attained by means of magnetic particles specifically functionalized with lectins or boronic acids that bind to various structural motifs. Human serum was incubated with differentially functionalized magnetic micro-particles (lectins or boronic acids), and isolated proteins were digested with trypsin. Subsequently, the resulting complex mixture of peptides and glycopeptides was subjected to LC-MALDI analysis and database searching. In parallel, a second magnetic bead capturing was performed on the peptide level to separate and analyze by LC-MALDI intact glycopeptides, both peptide sequence and glycan structure. Detection of glycopeptides was achieved by means of a software algorithm that allows extraction and characterization of potential glycopeptide candidates from large LC-MALDI-MS/MS data sets, based on N-glycopeptide-specific fragmentation patterns and characteristic fragment mass peaks, respectively. By means of fast and simple glycospecific capturing applied in conjunction with extensive LC-MALDI-MS/MS analysis and novel data analysis tools, a high number of low-abundant proteins were identified, comprising known or predicted glycosylation sites. According to the specific binding preferences of the different types of beads, complementary results were obtained from the experiments using either magnetic ConA-, LCA-, WGA-, and boronic acid beads, respectively. PMID:17916798
Development of low loss hexaferrite materials for microwave applications
NASA Astrophysics Data System (ADS)
Su, Zhijuan
Hexaferrites have been widely used in microwave and millimeter wave devices as permanent magnets and as gyromagnetic materials, e.g., in circulators, filters, isolators, inductors, and phase shifters. As a critical component in radar and modern wireless communication systems, it is the microwave circulator that has drawn much attention. Many efforts have been made to design light and miniature circulators with self-biased ferrite materials. We report the magnetic and structural properties of a series of W-type barium hexaferrites of composition BaZn2-xCoxFe16O27 where x=0.15, 0.20, and 0.25. The anisotropy field of these BaW ferrites decreased with the substitution of divalent Co ions, while, they maintained crystallographic c-axis texture. The measured anisotropy field was ~10 kOe, and a hysteresis loop squareness Mr/Ms=79% was obtained due to well-controlled grain size within the range of single domain scale. U-type barium hexaferrite thin films were deposited on (0001) sapphire substrates by pulsed laser deposition. The results indicate a measured anisotropy field of ~8 kOe, and the saturation magnetization (4piMs) of 3.6 kG. More interestingly, an optimal post-deposition annealing of the films results in a strong (0, 0, n) crystallographic texture and a high squareness (Mr/Ms= 92%) out of the film plane. Furthermore, the highly self-biased ferrite films exhibited low FMR linewidth of ~200 Oe. Improved performance and miniaturization are needed to meet the ever-increasing demands of devices used in ultra-high frequency (UHF), L-band, and S-band, which are of particular interest in a variety of commercial and defense related applications. Utilizing materials possessing high permeability and permittivity with low magnetic losses is a promising solution. As a critical component in radar and modern wireless communication systems, antenna elements with compact size are constantly sought. Ferrite composites of the nominal composition Ba3Co2+xIrxFe24-2xO41 were studied in order to achieve low magnetic and dielectric losses and equivalent permittivity and permeability over a frequency range of 0.3-1 GHz. Crystallographic structure was characterized by X-ray diffraction, which revealed a Z-type phase accompanied by increasing amounts of Y-type phase as the iridium amount was increased. The measured microwave dielectric and magnetic properties showed that the loss tandeltaepsilon and loss tandeltamicro were decreased by 80% and 90% at 0.8 GHz with the addition of iridium having x =0.12 and 0.15, respectively. An effective medium approximation was adopted to analyze the composite ferrites having mixed phase structures. Moreover, adding Bi2O3 resulted in equivalent values of real permittivity and real permeability over the studied frequency range. The resultant data gives rise to low loss factors (i.e., tandeltaepsilon/epsilon' = 0.008 and tandelta micro/micro'=0.037 at 0.8 GHz) while characteristic impedance was the same as that of free space impedance.
Preparation of highly pure α-MnBi phase via melt-spinning
NASA Astrophysics Data System (ADS)
Gabay, A. M.; Hadjipanayis, G. C.; Cui, J.
2018-05-01
High concentration of the magnetically hard α phase in the Mn-Bi alloys is important for the development of these alloys as rare-earth-free permanent magnets. Among several explored manufacturing methods, melt-spinning followed by annealing is known to be suitable of producing the most pure α structure. In this work, a series of melt-spun Mn100-xBix alloys was prepared with x = 43 - 51 at a wheel speed of 67 m/s by ejecting the alloys through orifices 0.17 mm and 0.27 mm in diameter. The smaller orifice diameter favored formation of an amorphous phase in the as-spun alloys as well as a higher saturation magnetization Ms in the alloys subsequently annealed at 300 °C. Although the most pure, 98 vol.%, α phase was obtained for the off-stoichiometric Mn55Bi45 composition, the Ms of this material was lowered, possibly because the excess Mn atoms induced antiferromagnetic coupling in the α phase. The highest Ms of 78 emu/g was obtained for a composition closer to the Mn50Bi50 stoichiometry, despite the slightly lower purity of α phase. Evolution of the room-temperature coercivity with the formation of the α phase in the melt-spun alloys was studied for the Mn55Bi45 ribbons compacted at 275 °C; the coercivity values of around 1 kOe obtained through this simple procedure are not sufficient for permanent magnet applications.
Epstein–Barr virus and multiple sclerosis: potential opportunities for immunotherapy
Pender, Michael P; Burrows, Scott R
2014-01-01
Multiple sclerosis (MS) is a common chronic inflammatory demyelinating disease of the central nervous system (CNS) causing progressive disability. Many observations implicate Epstein–Barr virus (EBV) in the pathogenesis of MS, namely universal EBV seropositivity, high anti-EBV antibody levels, alterations in EBV-specific CD8+ T-cell immunity, increased spontaneous EBV-induced transformation of peripheral blood B cells, increased shedding of EBV from saliva and accumulation of EBV-infected B cells and plasma cells in the brain. Several mechanisms have been postulated to explain the role of EBV in the development of MS including cross-reactivity between EBV and CNS antigens, bystander damage to the CNS by EBV-specific CD8+ T cells, activation of innate immunity by EBV-encoded small RNA molecules in the CNS, expression of αB-crystallin in EBV-infected B cells leading to a CD4+ T-cell response against oligodendrocyte-derived αB-crystallin and EBV infection of autoreactive B cells, which produce pathogenic autoantibodies and provide costimulatory survival signals to autoreactive T cells in the CNS. The rapidly accumulating evidence for a pathogenic role of EBV in MS provides ground for optimism that it might be possible to prevent and cure MS by effectively controlling EBV infection through vaccination, antiviral drugs or treatment with EBV-specific cytotoxic CD8+ T cells. Adoptive immunotherapy with in vitro-expanded autologous EBV-specific CD8+ T cells directed against viral latent proteins was recently used to treat a patient with secondary progressive MS. Following the therapy, there was clinical improvement, decreased disease activity on magnetic resonance imaging and reduced intrathecal immunoglobulin production. PMID:25505955
Magnetic properties and structure of low temperature phase MnBi with island structure
NASA Astrophysics Data System (ADS)
Ito, Masashi; Tanaka, Yoshitomo; Satoh, Takuya; Mankey, Gary; Schad, Rainer; Suzuki, Takao
2017-05-01
The magnetic properties of the low temperature phase (LTP) MnBi thin films of islands structure are discussed. The LTP MnBi islands are formed onto silica substrates after the multilayers Bi(3.2nm)/Mn(2nm)x N are deposited and then annealed at 450C for 0.5hr, where N is the number of the repetition of a pair of Mn and Bi layer. Those islands are found to be of the LTP MnBi, with the c-axis orientation along the normal to the sample plane for N=10 ˜ 40. Their size vary from place to place, but are averagely of about a few hundred nm in height and a few μm in width for N from 10 to 40. For N=200, the elongated islands are formed densely, with the length of about a few tens of μm. The coverage of those islands increases with N. The temperature dependence of saturation magnetization Ms is qualitatively similar to that for bulk, though the absolute values for Ms are smaller by 20%. The magnetic anisotropy constants of Ku1 and Ku2 are evaluated for the samples with N=10 ˜ 40, where Ku1 and Ku2 are the magnetic anisotropy constants corresponding to the second and fourth power term in the uniaxial magnetic anisotropy energy expression. It is found that the Ku1 increases with T monotonously, reaching to about 1x107 erg/cc at 400K. On the other hand, the Ku2 remains nearly zero for temperatures below 300K, and then becomes negative, reaching to about 7 x 106 erg/cc at 400K. This is the first to report of the temperature dependence of Ku1 and Ku2 in the LTP MnBi of an island structure. It is also noted that the decrease of Ku for a temperature range beyond around 450 K is possibly due to the decrease of the Ku2 component, as demonstrated in the present study.
Preparation and characterization of electrodeposited cobalt nanowires
NASA Astrophysics Data System (ADS)
Irshad, M. I.; Ahmad, F.; Mohamed, N. M.; Abdullah, M. Z.
2014-10-01
Electrochemical deposition technique has been used to deposit cobalt nanowires into the nano sized channels of Anodized Aluminium Oxide (AAO) templates. CoCl2˙6H 2 O salt solution was used, which was buffered with H3BO3 and acidified by dilute H2SO4 to increase the plating life and control pH of the solution. Thin film of copper around 150 nm thick on one side of AAO template coated by e-beam evaporation system served as cathode to create electrical contact. FESEM analysis shows that the as-deposited nanowires are highly aligned, parallel to one another and have high aspect ratio with a reasonably high pore-filing factor. The TEM results show that electrodeposited cobalt nanowires are crystalline in nature. The Hysteresis loop shows the magnetization properties for in and out of plane configuration. The in plane saturation magnetization (Ms) is lower than out of plane configuration because of the easy axis of magnetization is perpendicular to nanowire axis. These magnetic nanowires could be utilized for applications such as spintronic devices, high density magnetic storage, and magnetic sensor applications.
In-Situ Preparation and Magnetic Properties of Fe3O4/WOOD Composite
NASA Astrophysics Data System (ADS)
Gao, Honglin; Zhang, Genlin; Wu, Guoyuan; Guan, Hongtao
2011-06-01
Fe3O4/wood composite, a magnetic material, was prepared by In-situ chemosynthesis method at room temperature. The X-ray diffraction (XRD) shows that the average partical size of Fe3O4 was about 14 nm. The magnetic properties of the resulting composites were investigated by vibrating sample magnetometer (VSM). The composites have saturation magnetization (Ms) values from 4.7 to 25.3 emu/g with the increase of weight percent gains (WPG) of the wood for the composites, but coercive forces (Hc) are invariable, which is different from the magnetic materials reported before. It may be due to the fact that the interaction between wood and Fe3O4 becomes stronger when less of Fe3O4 particles are introduced in the composition, and this also changes the surface anisotropy (Ks) of the magnetism. A structural characterization by Fourier transform infrared (FTIR) proved the interaction between Fe3O4 particles and wood matrix, and it also illustrates that this interaction influences the coercive force of the composite.
Steady-state free precession with myocardial tagging: CSPAMM in a single breathhold.
Zwanenburg, Jaco J M; Kuijer, Joost P A; Marcus, J Tim; Heethaar, Robert M
2003-04-01
A method is presented that combines steady-state free precession (SSFP) cine imaging with myocardial tagging. Before the tagging preparation at each ECG-R wave, the steady-state magnetization is stored as longitudinal magnetization by an alpha/2 flip-back pulse. Imaging is continued immediately after tagging preparation, using linearly increasing startup angles (LISA) with a rampup over 10 pulses. Interleaved segmented k-space ordering is used to prevent artifacts from the increasing signal during the LISA rampup. First, this LISA-SSFP method was evaluated regarding ghost artifacts from the steady-state interruption by comparing LISA with an alpha/2 startup method. Next, LISA-SSFP was compared with spoiled gradient echo (SGRE) imaging, regarding tag contrast-to-noise ratio and tag persistence. The measurements were performed in phantoms and in six subjects applying breathhold cine imaging with tagging (temporal resolution 51 ms). The results show that ghost artifacts are negligible for the LISA method. Compared to the SGRE reference, LISA-SSFP was two times faster, with a slightly better tag contrast-to-noise. Additionally, the tags persisted 126 ms longer with LISA-SSFP than with SGRE imaging. The high efficiency of LISA-SSFP enables the acquisition of complementary tagged (CSPAMM) images in a single breathhold. Copyright 2003 Wiley-Liss, Inc.
NASA Astrophysics Data System (ADS)
Nguyen, T. N. Anh; Fedotova, J.; Kasiuk, J.; Bayev, V.; Kupreeva, O.; Lazarouk, S.; Manh, D. H.; Vu, D. L.; Chung, S.; Åkerman, J.; Altynov, V.; Maximenko, A.
2018-01-01
For the first time, nanoporous Al2O3 templates with smoothed surface relief characterized by flattened interpore areas were used in the fabrication of Co/Pd and Co/Pt multilayers (MLs) with strong perpendicular magnetic anisotropy (PMA). Alternating gradient magnetometry (AGM) revealed perfectly conserved PMA in the Co/Pd and Co/Pt porous MLs (antidot arrays) with a ratio of remanent magnetization (Mr) to saturation magnetization (MS) of about 0.99, anisotropy fields (Ha) of up to 2.6 kOe, and a small deviation angle of 8° between the easy magnetization axis and the normal to the film surface. The sufficient magnetic hardening of the porous MLs with enhanced coercive field HC of up to ∼1.9 kOe for Co/Pd and ∼1.5 kOe for Co/Pt MLs, as compared to the continuous reference samples (∼1.5-2 times), is associated with the pinning of the magnetic moments on the nanopore edges. Application of the Stoner-Wohlfarth model for fitting the experimental M/MS(H) curves yielded clear evidence of the predominantly coherent rotation mechanism of magnetization reversal in the porous films.
Reynolds, R.L.; Rosenbaum, J.G.; Van Metre, P.; Tuttle, M.; Callender, E.; Goldin, A.
1999-01-01
Combined magnetic and geochemical studies were conducted on sediments from White Rock Lake, a reservoir in suburban Dallas (USA), to investigate how land use has affected sediment and water quality since the reservoir was filled in 1912. The chronology of a 167-cm-long core is constrained by the recognition of the pre-reservoir surface and by 137Cs results. In the reservoir sediments, magnetic susceptibility (MS) and isothermal remanent magnetization (IRM) are largely carried by detrital titanomagnetite that originally formed in igneous rocks. Titanomagnetite and associated hematite are the dominant iron oxides in a sample from the surficial deposit in the watershed but are absent in the underlying Austin Chalk. Therefore, these minerals were transported by wind into the watershed. After about 1960, systematic decreases in Ti, Fe, and Al suggest diminished input of detrital Fe-Ti oxides from the surficial deposits. MS and IRM remain constant over this interval, however, implying compensation by an increase in strongly magnetic material derived from human activity. Anthropogenic magnetite in rust and ferrite spherules (from fly ash?) are more common in sediment deposited after about 1970 than before and may account for the constant magnetization despite the implied decrease in detrital Fe-Ti oxides. An unexpected finding is the presence of authigenic greigite (Fe3S4), the abundance of which is at least partly controlled by climate. Greigite is common in sediments that predate about 1975, with zones of concentration indicated by relatively high IRM/MS. High greigite contents in sediment deposited during the early to mid-1950s and during the mid-1930s correspond to several-year periods of below-average precipitation and drought from historical records. Relatively long water-residence times in the reservoir during these periods may have led to elevated levels of sulfate available for bacterial sulfate reduction. The sulfate was probably derived via the oxidation of pyrite that is common in the underlying Austin Chalk. These results provide a basis for the paleoenvironmental interpretation of greigite occurrence in older lake sediments. The results also indicate that greigite formed rapidly and imply that it can be preserved in the amounts produced over a short time span (in this lake, only a few years). This finding thus suggests that, in some lacustrine settings, greigite is capable of recording paleomagnetic secular variation.
MMS Observations of Vorticity Near Sites of Magnetic Reconnection
NASA Astrophysics Data System (ADS)
Paterson, W. R.; Giles, B. L.; Avanov, L. A.; Boardsen, S. A.; Dorelli, J.; Gershman, D. J.; Mackler, D. A.; Moore, T. E.; Pollock, C. J.; Schiff, C.; Shuster, J. R.; Viñas, A. F.; Russell, C. T.; Strangeway, R. J.; Burch, J. L.; Torbert, R. B.
2017-12-01
With highly capable plasma instruments on four spacecraft flown in tetrahedral formation, it is possible for MMS investigators to approximate spatial derivatives of the plasma parameters observed. Here, we examine vorticity of the electron and ion components of the plasma computed from the curl of velocity as measured by the Fast Plasma Investigation (FPI). Vorticity of magnetospheric plasma has not previously been studied on scales of tens-of-km to less than 10 km, which are the typical inter-spacecraft separations for MMS. Nor has it been explored on time scales of 30 ms for electrons and 150 ms for ions, which are the burst data rates for the FPI spectrometers. Review of observations from the magnetopause and magnetotail phases of the mission finds increases in vorticity associated with near encounters with the electron diffusion region, with nearby regions of measurable current, and with elevated electron and ion temperatures. These are suggestive of a possible role for turbulence in magnetic reconnection. In this presentation we provide an assessment of the quality of these measurements and discuss their potential significance.
NASA Astrophysics Data System (ADS)
Praveena, K.; Chen, Hsiao-Wen; Liu, Hsiang-Lin; Sadhana, K.; Murthy, S. R.
2016-12-01
Nowadays electronic industries prerequisites magnetic materials, i.e., iron rich materials and their magnetic alloys. However, with the advent of high frequency applications, the standard techniques of reducing eddy current losses, using iron cores, were no longer efficient or cost effective. Current market trends of the switched mode power supplies industries required even low energy losses in power conversion with maintenance of adequate initial permeability. From the above point of view, in the present study we aimed at the production of Manganese-Zinc ferrites prepared via solution combustion method using mixture of fuels and achieved low loss, high saturation magnetization, high permeability, and high magnetic domain relaxation frequency. The as-synthesized Zn2+ substituted MnFe2O4 were characterized by X-ray diffractometer (XRD) and transmission electron microscopy (TEM). The fractions of Mn2+, Zn2+ and Fe2+ cations occupying tetrahedral sites along with Fe occupying octahedral sites within the unit cell of all ferrite samples were estimated by Raman scattering spectroscopy. The magnetic domain relaxation was investigated by inductance spectroscopy (IS) and the observed magnetic domain relaxation frequency (fr) was increased with the increase in grain size. The real and imaginary part of permeability (μ‧ and μ″) increased with frequency and showed a maximum above 100 MHz. This can be explained on the basis of spin rotation and domain wall motion. The saturation magnetization (Ms), remnant magnetization (Mr) and magneton number (μB) decreased gradually with increasing Zn2+ concentration. The decrease in the saturation magnetization was discussed with Yafet-Kittel (Y-K) model. The Zn2+ concentration increases the relative number of ferric ions on the A sites, reduces the A-B interactions. The frequency dependent total power losses decreased as the zinc concentration increased. At 1 MHz, the total power loss (Pt) changed from 358 mW/cm3 for x=0-165 mW/cm3 for x=0.9. Pt for all the Zn doped samples exhibited the temperature stability up to 100 °C.
Dhib-Jalbut, Suhayl; Dowling, Peter; Durelli, Luca; Ford, Corey; Giovannoni, Gavin; Halper, June; Harris, Colleen; Herbert, Joseph; Li, David; Lincoln, John A.; Lisak, Robert; Lublin, Fred D.; Lucchinetti, Claudia F.; Moore, Wayne; Naismith, Robert T.; Oehninger, Carlos; Simon, Jack; Sormani, Maria Pia
2012-01-01
It has recently been suggested that the Lublin-Reingold clinical classification of multiple sclerosis (MS) be modified to include the use of magnetic resonance imaging (MRI). An international consensus conference sponsored by the Consortium of Multiple Sclerosis Centers (CMSC) was held from March 5 to 7, 2010, to review the available evidence on the need for such modification of the Lublin-Reingold criteria and whether the addition of MRI or other biomarkers might lead to a better understanding of MS pathophysiology and disease course over time. The conference participants concluded that evidence of new MRI gadolinium-enhancing (Gd+) T1-weighted lesions and unequivocally new or enlarging T2-weighted lesions (subclinical activity, subclinical relapses) should be added to the clinical classification of MS in distinguishing relapsing inflammatory from progressive forms of the disease. The consensus was that these changes to the classification system would provide more rigorous definitions and categorization of MS course, leading to better insights as to the evolution and treatment of MS. PMID:24453741
Differentiation of Neuromyelitis Optica from Multiple Sclerosis on Spinal Magnetic Resonance Imaging
Khan, Majid; Schlakman, Bruce; Penman, Alan; Gatlin, Joseph; Herndon, Robert
2012-01-01
In order to examine the accuracy of magnetic resonance imaging (MRI)–based diagnosis of neuromyelitis optica (NMO) versus multiple sclerosis (MS), we performed a retrospective, rater-blinded review of 29 cases of NMO and 30 cases of MS using the criteria of long (more than three vertebral levels), continuous lesions with a central cord location for NMO and more peripheral and patchy lesions for MS. Using these criteria, two raters were able to distinguish the two conditions with a good degree of confidence, particularly when the imaging was performed at the time of an acute cord attack. The sensitivity and specificity for diagnosis of NMO were 86.2% and 93.3%, respectively, for Rater A and 96.4% and 78.6%, respectively, for Rater B, with a kappa value of 0.72. Thus there are significant differences in lesion characteristics that allow the distinction on spinal cord imaging between MS and NMO with a moderately high degree of confidence. The location of the lesion as evident on MRI of the spine can be regarded as a distinguishing diagnostic feature between MS and NMO. PMID:24453753
Sweet cherry softening accompanied with moisture migration and loss during low-temperature storage.
Zhu, Danshi; Liang, Jieyu; Liu, He; Cao, Xuehui; Ge, Yonghong; Li, Jianrong
2018-08-01
Hardness is one of the important qualities influencing consumer appeal and marketing of fresh sweet cherry (Prunus avium L.). Moisture loss is one of the main causative factors of cherry softening. In this work, moisture loss and softening process of sweet cherry during postharvest storage at 0 and 4 °C were studied. In addition, low-field 1 H nuclear magnetic resonance (LF-NMR) was used to analyze water distribution and migration in sweet cherry during storage at 4 °C. Moisture content correlated significantly (p < 0.01) with both skin and flesh hardness of cherry fruit at the two storage temperatures. According to the transverse relaxation curve, relaxation time, as T 21 (0.01-10 ms), T 22 (10-150 ms), and T 23 (150-1000 ms) were ascribed to cell wall protons, cytoplasmic water, and vacuolar water respectively. Contents of cytoplasmic (p < 0.05) and vacuolar water (p < 0.01) changed significantly with storage time. Magnetic resonance imaging results illustrated that water distributes uniformly in fresh tissue. With prolonged storage time, free water content increased gradually, and then internal damage occurred. Sweet cherry softening closely correlated with moisture loss during low-temperature storage. LF-NMR is a useful technique to investigate moisture migration of fruits and vegetables. © 2017 Society of Chemical Industry. © 2017 Society of Chemical Industry.
Transient dynamics of secondary radiation from an HF pumped magnetized space plasma
NASA Astrophysics Data System (ADS)
Norin, L.; Grach, S. M.; Thidé, B.; Sergeev, E. N.; Leyser, T. B.
2007-09-01
In order to systematically analyze the transient wave and radiation processes that are excited when a high-frequency (HF) radio wave is injected into a magnetized space plasma, we have measured the secondary radiation, or stimulated electromagnetic emission (SEE), from the ionosphere, preconditioned such that geomagnetic field-aligned plasma irregularities are already present. The transient dynamics experiments were made using a duty cycle of the HF radio wave of 200 ms (180 ms on and 20 ms off) and 100 ms (80 ms on and 20 ms off) for various frequencies near the fifth harmonic of the local ionospheric electron cyclotron frequency. Within the first 10 ms after the radio pulse turn-on, frequency downshifted structures of the SEE exhibit an overshoot with a maximum at 3 ms < t < 8 ms, whereas the upshifted spectral components do not exhibit this feature. The relative magnitude of the overshoot is strongly dependent on the frequency offset of the pump from the harmonic of the electron cyclotron frequency. A transient blue-shifted frequency component is identified. This component is upshifted from the pump by 14 kHz < Δ f < 55 kHz and exists only within the first 10 ms after the radio pulse turn-on. On a longer time scale we analyze the amplitude modulation, or ``ringing,'' of the reflected radio wave, (also known as ``quasi-periodic oscillations'' or ``spikes''). The ringing has a frequency of the order 15-20 Hz and we show that this phenomenon is also present in the SEE sidebands and is synchronized with the ringing of the reflected HF wave itself.
Yang, Wen; Li, Tengfei; Shu, Chang; Ji, Shunli; Wang, Lei; Wang, Yan; Li, Duo; Mtalimanja, Michael; Sun, Luning; Ding, Li
2018-05-10
A method is described for the determination of proteins with LC-MS/MS enabled by a small molecule (adenosine) barcode and based on a double-recognition sandwich structure. The coagulation protein thrombin was chosen as the model analyte. Magnetic nanoparticles were functionalized with aptamer29 (MNP/apt29) and used to capture thrombin from the samples. MNP/apt29 forms a sandwich with functionalized gold nanoparticles modified with (a) aptamer15 acting as thrombin-recognizing element and (b) a large number of adenosine as mass barcodes. The sandwich formed (MNP/apt29-thrombin-apt15/AuNP/adenosine) can ben magnetically separated from the sample. Mass barcodes are subsequently released from the sandwiched structure for further analysis by adding 11-mercaptoundecanoic acid. Adenosine is then detected by LC-MS/MS as it reflects the level of thrombin with impressively amplified signal. Numerous adenosines introduced into the sandwich proportional to the target concentration further amplify the signal. Under optimized conditions, the response is linearly proportional to the thrombin concentration in the range of 0.02 nM to 10 nM, with a detection limit of 9 fM. The application of this method to the determination of thrombin in spiked plasma samples gave recoveries that ranged from 92.3% to 104.7%. Graphical abstract Schematic representation of a method for the determination of thrombin with LC-MS/MS. The method is based on a double-recognition sandwiched structure. With LC-MS/MS, mass barcodes (adenosine) are detected to quantify thrombin, which amplifies the detection signal impressively.
NASA Astrophysics Data System (ADS)
Rush, Michael D.; Walker, Elisabeth M.; Prehna, Gerd; Burton, Tristesse; van Breemen, Richard B.
2017-03-01
To overcome limiting factors in mass spectrometry-based screening methods such as automation while still facilitating the screening of complex mixtures such as botanical extracts, magnetic microbead affinity selection screening (MagMASS) was developed. The screening process involves immobilization of a target protein on a magnetic microbead using a variety of possible chemistries, incubation with mixtures of molecules containing possible ligands, a washing step that removes non-bound compounds while a magnetic field retains the beads in the microtiter well, and an organic solvent release step followed by LC-MS analysis. Using retinoid X receptor-α (RXRα) as an example, which is a nuclear receptor and target for anti-inflammation therapy as well as cancer treatment and prevention, a MagMASS assay was developed and compared with an existing screening assay, pulsed ultrafiltration (PUF)-MS. Optimization of MagMASS involved evaluation of multiple protein constructs and several magnetic bead immobilization chemistries. The full-length RXRα construct immobilized with amylose beads provided optimum results. Additional enhancements of MagMASS were the application of 96-well plates to enable automation, use of UHPLC instead of HPLC for faster MS analyses, and application of metabolomics software for faster, automated data analysis. Performance of MagMASS was demonstrated using mixtures of synthetic compounds and known ligands spiked into botanical extracts.
Synthesis and Magnetic, Thermal, and Electrical Measurements on Complex non-Cuprate Superconductors
DOE Office of Scientific and Technical Information (OSTI.GOV)
Henry, Laurence L
2006-02-27
The project investigated superconductivity in non-cuprate materials with critical temperatures, T{sub c}, in excess of 20 K in order to understand the thermodynamics of several of these materials. The project is a cooperative effort between investigators at Southern University (SU), Louisiana State University (LSU), and Los Alamos National Laboratory (LANL). It involved synthesis of high quality samples, and subsequent detailed magnetic, thermal and electrical measurements on them. The project provided a PhD Thesis research experience and training for a graduate student, Ms. Robin Macaluso. High quality, single crystal samples were synthesized by Ms. Macaluso under the direction of one ofmore » the CO-PIS, John Sarao, during the summer while she was a visitor at LANL being supported by this grant. On these samples magnetic measurements were performed at SU, thermal and electrical measurements were made in the LSU Physics and Astronomy Department. The crystallographic properties were determined in the LSU Chemistry Department by Ms. Macaluso under the direction of her dissertation advisor, Dr. Julia Chan. Additional high field magnetic measurements on other samples were performed at the National High Magnetic Field Laboratory (NHMFL) both in Tallahassee and at LANL. These measurements involved another graduate student, Umit Alver, who used some of the measurements as part of his PhD dissertation in Physics at LSU.« less
NASA Astrophysics Data System (ADS)
Mane, Sagar M.; Tirmali, Pravin M.; Ranjit, Bhakti; Khan, Madiha; Khan, Nargis; Tarale, Arjun N.; Kulkarni, Shrinivas B.
2018-07-01
Present paper reports the synthesis of multiferroic composite (1-x) [Ba0.8Sr0.2Ti)O3]-x[Co0.9Ni0.1Fe2O4] were x = 0.1, 0.2, 0.3 and 0.4. Both phases of the composite i.e. ferroelectric (BST) and ferrite (CNFO) are synthesized via hydroxide co-precipitation method followed by microwave sintering technique at 1100 °C. These composites were characterized for their structural, microstructural, dielectric analysis, magnetodielectric (MD) effect and ferroelectric properties. Presence of both the phases ferroelectric (BST) and ferromagnetic (CNFO) are confirmed by the x-ray diffraction and scanning electron microscopic analysis. Maxwell-Wagner type dielectric dispersion is observed in frequency dependent dielectric measurement. Temperature-dependent dielectric properties were measured from 25 °C to 500 °C at various applied frequencies. Ferroelectric behavior in the composites was confirmed by the polarization vs. Electric field analysis. The magnetodielectric effect was studied in the presence of applied magnetic field from 0 to 1 Tesla. Magnetocapacitance (%) increases with increase in the ferrite concentration in the ferroelectric phase. The maximum percentage of magnetocapacitance is observed in 60BST-40CNFO composite which is MC = 30% at the frequency 1 KHz with the applied magnetic field is 1-Tesla. Room temperature magnetic hysteresis loops show an increase in saturation magnetization (Ms) with an increase in ferrite concentration.
Status of Standardization Projects
1991-09-30
N N PROJECT ................. TITLE .................. PY TY SN YN SRR SRR SRR SRR T YT YT T RT S D 6640 1627 07 MS36458 BAR SPIN MAGNETIC EGG SHAPE...H5 913 914 914 A EA MS 99 DP N C 6640 1736 10 MS36234 INCUBATOR BACTERIA & EGG INCUBAT EA H5 913 914 914 A EA MS 99 DP N C 6640 1736 11 MS36154 OVEN...6695 0085 A-A TESTER TEMPERATURE INDICATOR 82 B4 A 881 891 903 A ER AS 99 GS U B 6695 0096 MIL-C-3554 CANDLER, EGG MB DM H5 904 914 914 A MD MS 03 N
DOE Office of Scientific and Technical Information (OSTI.GOV)
Stoneking, M.R.; Lanier, N.E.; Prager, S.C.
1996-12-01
Current profile control is employed in the Madison Symmetric Torus reversed field pinch to reduce the magnetic fluctuations responsible for anomalous transport. An inductive poloidal electric field pulse is applied in the sense to flatten the parallel current profile, reducing the dynamo fluctuation amplitude required to sustain the equilibrium. This technique demonstrates a substantial reduction in fluctuation amplitude (as much as 50%), and improvement in energy confinement (from 1 ms to 5 ms); a record low fluctuation (0.8%) and record high temperature (615 eV) for this device were observed simultaneously during current drive experiments. Plasma beta increases by 50% andmore » the Ohmic input power is three times lower. Particle confinement improves and plasma impurity contamination is reduced. The results of the transient current drive experiments provide motivation for continuing development of steady-state current profile control strategies for the reversed field pinch.« less
Patients with multiple sclerosis present low levels of empathy.
Almeida, Marcos Barbosa de; Going, Luana Carramilo; Fragoso, Yara Dadalti
2016-12-01
This is a single center, cross-sectional study, of 34 patients with MS and 34 matched control subjects. A specific questionnaire (empathy quotient) was used. Patients with MS showed significantly lower levels of empathy. This finding was not correlated with disease duration, degree of disability, drugs for treating MS or lesion load on resonance magnetic imaging. Decreased empathy is a frequent condition in patients with MS and should be addressed in order to diminish the psychosocial burden of this neurological disease.
Bateman, Grant A; Lechner-Scott, Jeannette; Lea, Rodney A
2016-09-22
It has been suggested there is a chronic neurodegenerative disorder, underlying the pathophysiology of multiple sclerosis (MS), which is distinct from the more obvious immune-mediated attack on the white matter. Limited data exists indicating there is an alteration in pulse wave propagation within the craniospinal cavity in MS, similar to the findings in normal pressure hydrocephalus (NPH). It is hypothesized MS may harbor pulse wave encephalopathy. The purpose of this study is to compare blood flow and pulse wave measurements in MS patients with a cohort of NPH patients and control subjects, to test this hypothesis. Twenty patients with MS underwent magnetic resonance (MR) flow quantification techniques. Mean blood flow and stroke volume were measured in the arterial inflow and venous out flow from the sagittal (SSS) and straight sinus (ST). The arteriovenous delay (AVD) was defined. The results were compared with both age-matched controls and NPH patients. In MS there was a 35 % reduction in arteriovenous delay and a 5 % reduction in the percentage of the arterial inflow returning via the sagittal sinus compared to age matched controls. There was an alteration in pulse wave propagation, with a 26 % increase in arterial stroke volume but 30 % reduction in SSS and ST stroke volume. The AVD and blood flow changes were in the same direction to those of NPH patients. There are blood flow and pulsation propagation changes in MS patients which are similar to those of NPH patients. The findings would be consistent with an underlying pulse wave encephalopathy component in MS.
Cegłowski, Michał; Kurczewska, Joanna; Smoluch, Marek; Reszke, Edward; Silberring, Jerzy; Schroeder, Grzegorz
2015-09-07
In this paper, a procedure for the preconcentration and transport of mixtures of acids, bases, and drug components to a mass spectrometer using magnetic scavengers is presented. Flowing atmospheric pressure afterglow mass spectrometry (FAPA-MS) was used as an analytical method for identification of the compounds by thermal desorption from the scavengers. The proposed procedure is fast and cheap, and does not involve time-consuming purification steps. The developed methodology can be applied for trapping harmful substances in minute quantities, to transport them to specialized, remotely located laboratories.
Yaldizli, Özgür; Sethi, Varun; Pardini, Matteo; Tur, Carmen; Mok, Kin Y; Muhlert, Nils; Liu, Zheng; Samson, Rebecca S; Wheeler-Kingshott, Claudia A M; Yousry, Tarek A; Houlden, Henry; Hardy, John; Miller, David H; Chard, Declan T
2016-05-01
The HLA-DRB*1501 haplotype influences the risk of developing multiple sclerosis (MS), but it is not known how it affects grey matter pathology. To assess HLA-DRB(*)1501 effects on magnetic resonance imaging (MRI) cortical grey matter pathology. Whole and lesional cortical grey matter volumes, lesional and normal-appearing grey matter magnetization transfer ratio were measured in 85 people with MS and 36 healthy control subjects. HLA-DRB(*)1501 haplotype was determined by genotyping (rs3135388). No significant differences were observed in MRI measures between the HLA-DRB(*)1501 subgroups. The HLA-DRB(*)1501 haplotype is not strongly associated with MRI-visible grey matter pathology. Copyright © 2016 Elsevier B.V. All rights reserved.
Exchange stiffness in thin film Co alloys
NASA Astrophysics Data System (ADS)
Eyrich, C.; Huttema, W.; Arora, M.; Montoya, E.; Rashidi, F.; Burrowes, C.; Kardasz, B.; Girt, E.; Heinrich, B.; Mryasov, O. N.; From, M.; Karis, O.
2012-04-01
The exchange stiffness (Aex) is one of the key parameters controlling magnetization reversal in magnetic materials. We used a method based on the spin spiral formation in two ferromagnetic films antiferromagnetically coupled across a non-magnetic spacer layer and Brillouin scattering to measure Aex for a series of Co1-δXδ (X = Cr, Ni, Ru, Pd, Pt) thin film alloys. The results show that Aex of Co alloys does not necessarily scale with Ms; Aex approximately decreases at the rate of 1.1%, 1.5%, 2.1%, 3.5%, and 5.6%, while Ms decreases at the rate of 1.1%, 0.5%, 1.1%, 3.7%, and 2.5% per addition of 1 at % of Pt, Ni, Pd, Cr, and Ru, respectively.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Kuanr, Bijoy K.; Department of Physics, University of Colorado, 1420 Austin Bluffs Parkway, Colorado Springs, CO 80918; Mishra, S.R., E-mail: srmishra@memphis.edu
2016-04-15
Highlights: “CoFe{sub 2−x} Al{sub x}O{sub 4} ferrite nanoparticles: Static and dynamic properties” • Grain size reduction with Al{sup 3+} content. • Reduction in Ms, Hc, with increasing Al{sup 3+} content. • Increase in resonance frequency with applied field. • Decrease in resonance field with increase in Al{sup 3+} content. • Decrease in Gilbert parameter with increase in Al{sup 3+} content. - Abstract: Aluminum doped CoFe{sub 2−x}Al{sub x}O{sub 4} (0 ≤ x ≤ 0.9) nanoparticles were synthesized via auto-combustion. Formation of single phase cubic spinel structure was confirmed by X-ray diffraction (XRD) analysis. XRD analysis suggests a linear decrease in latticemore » cell parameters and grain size (90–55 nm) with the increase in Al{sup 3+} content. The saturation magnetization of samples decrease with increasing Al{sup 3+} content due to magnetic dilution effect. A concomitant linear reduction in coercivity was also observed mainly due to decrease in magnetic anisotropy. Frequency and field dependent dynamic properties of nanoparticles were studied by ferromagnetic resonance (FMR) technique. The resonance frequency increases linearly with magnetic field for all nanoparticles. Magnetic field dependent experimental absorption data (S{sub 21} vs. frequency) were compared with effective medium theory considering an effective demagnetization field and was observed to be in good agreement with each other. High Al{sup 3+} content reduces the Gilbert damping parameter thus making CoFe{sub 2−x}Al{sub x}O{sub 4} as an attractive material for high frequency applications.« less
NASA Astrophysics Data System (ADS)
Yasmin, Nazia; Mirza, Misbah; Muhammad, Safdar; Zahid, Maria; Ahmad, Mukhtar; Awan, M. S.; Muhammad, Altaf
2018-01-01
The M-type hexagonal ferrites with chemical formula SrFe12-xSmxO19 (x = 0, 0.01, 0.02, 0.03) were synthesized via sol-gel method. We studied the effects of substitution of rare earth on the structural and magnetic temperament of M-type hexaferrites. Scanning electron microscopy (SEM) and X-ray diffraction (XRD) strategies are employed for the systematical examination of micrographs and structures of the samples. The magnetic particularities are studied by the use of vibrating sample magnetometery. The M-H loops are used to investigate the hard magnetic behavior of all the samples. The substantial value of coercivity (>1 kOe) for all the samples shows that the particular sample is permanent magnet and reveals the hard magnetic action. It is observed that values of saturation magnetization (Mr) and remanence (Ms) decline with increasing the rare earth ions substitution. This decrease may follow spin canting and the magnetic dilution, which results in dislocation of superexchange interactions. The improvement in Hc may be because of large anisotropy of magnetocrystalline, where ion anisotropy of Fe2+ ion on the 2a site probably overriding in all hexaferrites series. The synthesized composites were useful for applications in magnetic microwave absorbing materials.
NASA Astrophysics Data System (ADS)
Gopi, D.; Ansari, M. Thameem; Shinyjoy, E.; Kavitha, L.
2012-02-01
Nowadays magnetic hydroxyapatite (m-HAP) has potential applications in biomedicine more especially for bone cancer treatment. In this paper the functionalization of the hydroxyapatite (HAP) with magnetite nanoparticle (MNP) through ultrasonic irradiation technique is reported and its spectral investigation has been carried out. The ultrasonic irradiation with two different frequencies of 28 kHz and 35 kHz at the power of 150 and 320 W, respectively, was employed for the synthesis of m-HAP. The ultrasound irradiation of 35 kHz at 320 W shows the efficient diffusion of MNP to the HAP host matrix leads to the formation of m-HAP. The ultrasonic irradiation technique does not require stabilizers as in the case of coprecipitation method hence the final product of pure m-HAP is obtained. The X-ray diffraction pattern shows the formation of magnetite nanoparticles which are functionalized with hydroxyapatite host matrix. The vibrating sample magnetometer curve exhibits the super paramagnetic property of the samples and the saturation magnetization ( Ms) value of the functionalized magnetic hydroxyapatite. The Ms value is found to be much less than that of pure magnetite nanoparticle and this decrement in Ms is due to the hindrance of magnetic domain of the particles with HAP. The portrayed Raman spectra discriminate between the m-HAP and MNP with corresponding vibrational modes of frequencies. The transmission electron micrograph shows excellent morphology of functionalized m-HAP in nanometer range. The atomic force microscopic investigation shows the 3-dimensional view of crust and trench shape of m-HAP. All these results confirm the formation of magnetic hydroxyapatite nanocomposite with typical magnetic property for biological applications.
Gopi, D; Ansari, M Thameem; Shinyjoy, E; Kavitha, L
2012-02-15
Nowadays magnetic hydroxyapatite (m-HAP) has potential applications in biomedicine more especially for bone cancer treatment. In this paper the functionalization of the hydroxyapatite (HAP) with magnetite nanoparticle (MNP) through ultrasonic irradiation technique is reported and its spectral investigation has been carried out. The ultrasonic irradiation with two different frequencies of 28kHz and 35kHz at the power of 150 and 320W, respectively, was employed for the synthesis of m-HAP. The ultrasound irradiation of 35kHz at 320W shows the efficient diffusion of MNP to the HAP host matrix leads to the formation of m-HAP. The ultrasonic irradiation technique does not require stabilizers as in the case of coprecipitation method hence the final product of pure m-HAP is obtained. The X-ray diffraction pattern shows the formation of magnetite nanoparticles which are functionalized with hydroxyapatite host matrix. The vibrating sample magnetometer curve exhibits the super paramagnetic property of the samples and the saturation magnetization (M(s)) value of the functionalized magnetic hydroxyapatite. The M(s) value is found to be much less than that of pure magnetite nanoparticle and this decrement in M(s) is due to the hindrance of magnetic domain of the particles with HAP. The portrayed Raman spectra discriminate between the m-HAP and MNP with corresponding vibrational modes of frequencies. The transmission electron micrograph shows excellent morphology of functionalized m-HAP in nanometer range. The atomic force microscopic investigation shows the 3-dimensional view of crust and trench shape of m-HAP. All these results confirm the formation of magnetic hydroxyapatite nanocomposite with typical magnetic property for biological applications. Copyright © 2011 Elsevier B.V. All rights reserved.
NASA Astrophysics Data System (ADS)
Aryal, Anil; Quetz, Abdiel; Pandey, Sudip; Dubenko, Igor; Stadler, Shane; Ali, Naushad
2018-05-01
The structural, magnetic, magnetocaloric, and transport properties of Ni50Mn35In15-xBix (x = 0, 0.25, 0.5, 1, 1.5) compounds has been studied through X-ray diffraction (XRD), differential scanning calorimetry, and magnetization measurements. A mixture of high temperature austenite phase (AP) and low temperature martensitic phase (MP) was observed from the XRD at room temperature. The saturation magnetization MS at 10 K was found to decrease with increasing Bi content. A shift in the martensitic transition temperature (TM) relative to the parent compound was observed with a maximum shift of ˜ 36 K for x = 1.5. Abnormal shifts in TC and TM to higher temperatures were observed at high field for x ≥ 0.5. Large magnetic entropy changes (ΔSM) of about 40 J/kg K (x = 0) and 34 J/kg K (x = 0.25) were observed at TM with H = 5 T, which reduced significantly for higher Bi concentrations. The doping of small amounts of Bi in the In sites increased the peak width of the ΔSM curves at the second order transition, leading to larger values of relative cooling power. A significant magnetoresistance (-30%) was observed near TM with ΔH = 5T for x = 0.5.
Huang, Susie Y; Witzel, Thomas; Wald, Lawrence L
2008-11-01
Control of the longitudinal magnetization in fast gradient-echo (GRE) sequences is an important factor in enabling the high efficiency of balanced steady-state free precession (bSSFP) sequences. We introduce a new method for accelerating the return of the longitudinal magnetization to the +z-axis that is independent of externally applied RF pulses and shows improved off-resonance performance. The accelerated radiation damping for increased spin equilibrium (ARISE) method uses an external feedback circuit to strengthen the radiation damping (RD) field. The enhanced RD field rotates the magnetization back to the +z-axis at a rate faster than T(1) relaxation. The method is characterized in GRE phantom imaging at 3T as a function of feedback gain, phase, and duration, and compared with results from numerical simulations of the Bloch equations incorporating RD. A short period of feedback (10 ms) during a refocused interval of a crushed GRE sequence allowed greater than 99% recovery of the longitudinal magnetization when very little T(2) relaxation had time to occur. An appropriate application might be to improve navigated sequences. Unlike conventional flip-back schemes, the ARISE "flip-back" is generated by the spins themselves, thereby offering a potentially useful building block for enhancing GRE sequences.
Poutiainen, Pekka; Jaronen, Merja; Quintana, Francisco J.; Brownell, Anna-Liisa
2016-01-01
Non-invasive molecular imaging techniques can enhance diagnosis to achieve successful treatment, as well as reveal underlying pathogenic mechanisms in disorders such as multiple sclerosis (MS). The cooperation of advanced multimodal imaging techniques and increased knowledge of the MS disease mechanism allows both monitoring of neuronal network and therapeutic outcome as well as the tools to discover novel therapeutic targets. Diverse imaging modalities provide reliable diagnostic and prognostic platforms to better achieve precision medicine. Traditionally, magnetic resonance imaging (MRI) has been considered the golden standard in MS research and diagnosis. However, positron emission tomography (PET) imaging can provide functional information of molecular biology in detail even prior to anatomic changes, allowing close follow up of disease progression and treatment response. The recent findings support three major neuroinflammation components in MS: astrogliosis, cytokine elevation, and significant changes in specific proteins, which offer a great variety of specific targets for imaging purposes. Regardless of the fact that imaging of astrocyte function is still a young field and in need for development of suitable imaging ligands, recent studies have shown that inflammation and astrocyte activation are related to progression of MS. MS is a complex disease, which requires understanding of disease mechanisms for successful treatment. PET is a precise non-invasive imaging method for biochemical functions and has potential to enhance early and accurate diagnosis for precision therapy of MS. In this review we focus on modulation of different receptor systems and inflammatory aspect of MS, especially on activation of glial cells, and summarize the recent findings of PET imaging in MS and present the most potent targets for new biomarkers with the main focus on experimental MS research. PMID:27695400
Stein, Anna; Goldmeier, Silvia; Voltolini, Sarah; Setogutti, Enio; Feldman, Carlos; Figueiredo, Eduardo; Eick, Renato; Irigoyen, Maria; Rigatto, Katya
2012-07-01
The association between renal hypoxia and the development of renal injury is well established. However, no adequate method currently exists to non-invasively measure functional changes in renal oxygenation in normal and injured patients. R2* quantification was performed using renal blood oxygen level-dependent properties. Five healthy normotensive women (50 ± 5.3 years) underwent magnetic resonance imaging in a 1.5T Signa Excite HDx scanner (GE Healthcare, Waukesha, WI). A multiple fast gradient-echo sequence was used to acquire R2*/T2* images (sixteen echoes from 2.1 ms/slice to 49.6 ms/slice in a single breath hold per location). The images were post-processed to generate R2* maps for quantification. Data were recorded before and at 30 minutes after the oral administration of an angiotensin II-converting enzyme inhibitor (captopril, 25 mg). The results were compared using an ANOVA for repeated measurements (mean + standard deviation) followed by the Tukey test. ClinicalTrials.gov: NCT01545479. A significant difference (p<0.001) in renal oxygenation (R2*) was observed in the cortex and medulla before and after captopril administration: right kidney, cortex = 11.08 ± 0.56 ms, medulla = 17.21 ± 1.47 ms and cortex = 10.30 ± 0.44 ms, medulla = 16.06 ± 1.74 ms, respectively; and left kidney, cortex= 11.79 ± 1.85 ms, medulla = 17.03 ± 0.88 ms and cortex = 10.89 ± 0.91 ms, medulla = 16.43 ± 1.49 ms, respectively. This result suggests that the technique efficiently measured alterations in renal blood oxygenation after angiotensin II-converting enzyme inhibition and that it may provide a new strategy for identifying the early stages of renal disease and perhaps new therapeutic targets.
Enhancement of ferromagnetic properties in composites of BaSnO3 and CoFe2O4
NASA Astrophysics Data System (ADS)
Manju, M. R.; Ajay, K. S.; D'Souza, Noel M.; Hunagund, Shivakumar; Hadimani, R. L.; Dayal, Vijaylakshmi
2018-04-01
In this paper, we report structural and magnetic properties of BaSnO3(BSO)(1-x)-CoFe2O4 (CFO)(x) composite (with x = 0%, 1% (C1), 2% (C2) and 5% (C3) in molar ratio) synthesized using nitrate precursor method. The X-ray diffraction (XRD) pattern of the composite powder confirmed presence of both BaSnO3 with the cubic perovskite structure and CoFe2O4 with the cubic spinel structure. No signature of any other phases in pure BaSnO3, CoFe2O4 and composites have been detected either in XRD or energy dispersive X-ray (EDS) analysis. The temperature dependent zero field cooled (ZFC) & field cooled (FC) magnetization and magnetic field dependence magnetization measurements have been carried at room temperature of the pure BaSnO3. We observe a weak ferromagnetic (FM) behavior at room temperature in pure BaSnO3 even though it is non-magnetic in nature. The room temperature Raman spectroscopy and electron spin resonance measurements of the sample confirm the presence of oxygen vacancy and formation of F-center, which is responsible for the FM behavior. The oxidation state and elemental analysis have been carried out using X-ray photoelectron spectroscopy (XPS). The magnetic field dependence of magnetization of the composite samples reveal increase of saturation magnetization (Ms), remanence magnetization (Mr) and coercivity (Hc) with increase in ferrite content in the composite. Significant enhancement in FM components is observed with lowering of temperature.
Stocke, Nathanael A; Sethi, Pallavi; Jyoti, Amar; Chan, Ryan; Arnold, Susanne M; Hilt, J Zach; Upreti, Meenakshi
2017-03-01
Magnetic hyperthermia as a treatment modality is acquiring increased recognition for loco-regional therapy of primary and metastatic lung malignancies by pulmonary delivery of magnetic nanoparticles (MNP). The unique characteristic of magnetic nanoparticles to induce localized hyperthermia in the presence of an alternating magnetic field (AMF) allows for preferential killing of cells at the tumor site. In this study we demonstrate the effect of hyperthermia induced by low and high dose of MNP under the influence of an AMF using 3D tumor tissue analogs (TTA) representing the micrometastatic, perfusion independent stage of triple negative breast cancer (TNBC) that infiltrates the lungs. While application of inhalable magnetic nanocomposite microparticles or magnetic nanocomposites (MnMs) to the micrometastatic TNBC model comprised of TTA generated from cancer and stromal cells, showed no measureable adverse effects in the absence of AMF-exposure, magnetic hyperthermia generated under the influence of an AMF in TTA incubated in a high concentration of MNP (1 mg/mL) caused significant increase in cellular death/damage with mechanical disintegration and release of cell debris indicating the potential of these inhalable composites as a promising approach for thermal treatment of diseased lungs. The novelty and significance of this study lies in the development of methods to evaluate in vitro the application of inhalable composites containing MNPs in thermal therapy using a physiologically relevant metastatic TNBC model representative of the microenvironmental characteristics in secondary lung malignancies. Copyright © 2016 Elsevier Ltd. All rights reserved.
NASA Astrophysics Data System (ADS)
Jang, Jung-tak; Bae, Seongtae
2017-10-01
The effects of Mg doping on the magnetic and AC self-heating temperature rising characteristics of γ-Fe2O3 superparamagnetic nanoparticles (SPNPs) were investigated for hyperthermia applications in biomedicine. The doping concentration of nonmagnetic Mg2+ cation was systematically controlled from 0 to 0.15 at. % in Mgx-γFe2O3 SPNPs during chemically and thermally modified one-pot thermal decomposition synthesis under bubbling O2/Ar gas mixture. It was empirically observed that the saturation magnetization (Ms) and the out-of-phase magnetic susceptibility ( χm″)of Mgx-γFe2O3 SPNPs were increased by increasing the Mg2+ cation doping concentration from 0.05 to 0.13 at. %. Correspondingly, the AC magnetically induced self-heating temperature (Tac,max) in solid state and the intrinsic loss power in water were increased up to 184 °C and 14.2 nH m2 kg-1 (Mgx-γFe2O3, x = 0.13), respectively, at the biologically and physiologically safe range of AC magnetic field (Happl × fappl = 1.2 × 109 A m-1 s-1). All the chemically and physically analyzed results confirmed that the dramatically improved AC magnetic induction heating characteristics and the magnetic properties of Mgx-γFe2O3 SPNPs (x = 0.13) are primarily due to the significantly enhanced magnetic susceptibility (particularly, χm″) and the improved AC/DC magnetic softness (lower AC/DC magnetic anisotropy) resulting from the systematically controlled nonmagnetic Mg2+ cation concentrations and distributions (occupation ratio) in the Fe vacancy sites of γ-Fe2O3 (approximately 12% vacancy), instead of typically well-known Fe3O4 (no vacancy) SPNPs. The cell viability and biocompatibility with U87 MG cell lines demonstrated that Mgx-γFe2O3 SPNPs (x = 0.13) has promising bio-feasibility for hyperthermia agent applications.
Fogel, Mark A.; Li, Christine; Nicolson, Susan C; Spray, Thomas L; Gaynor, J William; Fuller, Stephanie; Keller, Marc S.; Harris, Matthew A.; Yoganathan, Ajit P; Whitehead, Kevin K.
2015-01-01
Pulse wave velocity (PWV), a measure of arterial stiffness, is a known independent risk factor for cardiovascular events. Single ventricle patients who undergo aortic to pulmonary anastomosis (recon) have non-compliant patch material inserted into the neo-aorta, possibly increasing vessel stiffness and afterload. The purpose of this study is to determine if PWV differed in single ventricle patients who did and did not undergo aortic reconstruction (no-recon). We retrospectively reviewed cardiac magnetic resonance anatomic, cine and phase contrast evaluations in the ascending (AAo) and descending aorta (DAo) at the level of the diaphragm data from 126 single ventricle patients (8.6±8.0 years) from January 2012 to May, 2013. Significance = P<0.05. Seventy-five underwent recon and 51 did not. PWV in recon were significantly higher than in no-recon (3.9±0.9 m/s vs 3.2±1.0 m/s, P=0.008); in recon, patients > 13 years had a higher PWV than those < 7 years (4.5±0.6 vs 3.5±0.7 m/s, P=0.004). DAo distensibility was similar between both groups. There was no difference in age, body surface area or cardiac index between recon and no-recon. No correlations between various hemodynamic and ventricular function parameters with PWV were noted. In conclusion, PWV in recon is higher than in no-recon with similar DAo distensibility implicating the aortic reconstruction as a possible cause of increased afterload; older recon have stiffer aortas than younger ones possibly imposing an additional cardiovascular risk in the future. Other biomaterials may potentially moderate PWV if clinical outcome is adversely affected. PMID:25432153
NASA Astrophysics Data System (ADS)
Roche, T.; Thompson, M. C.; Mendoza, R.; Allfrey, I.; Garate, E.; Romero, J.; Douglass, J.
2016-11-01
External flux conserving coils were installed onto the exterior of the C-2U [M. W. Binderbauer et al., Phys. Plasmas 22, 056110 (2015)] confinement vessel to increase the flux confinement time of the system. The 0.5 in. stainless steel vessel wall has a skin time of ˜5 ms. The addition of the external copper coils effectively increases this time to ˜7 ms. This led to better-confined/longer-lived field-reversed configuration (FRC) plasmas. The fringing fields generated by the external coils have the side effect of rendering external field measurements invalid. Such measurements were key to the previous method of excluded flux calculation [M. C. Thompson et al., Rev. Sci. Instrum. 83, 10D709 (2012)]. A new array of B-dot probes and Rogowski coils were installed to better determine the amount of flux leaked out of the system and ultimately provide a more robust measurement of plasma parameters related to pressure balance including the excluded flux radius. The B-dot probes are surface mountable chip inductors with inductance of 33 μH capable of measuring the DC magnetic field and transient field, due to resistive current decay in the wall/coils, when coupled with active integrators. The Rogowski coils measure the total change in current in each external coil (150 A/2 ms). Currents were also actively driven in the external coils. This renders the assumption of total flux conservation invalid which further complicates the analysis process. The ultimate solution to these issues and the record breaking resultant FRC lifetimes will be presented.
Roche, T; Thompson, M C; Mendoza, R; Allfrey, I; Garate, E; Romero, J; Douglass, J
2016-11-01
External flux conserving coils were installed onto the exterior of the C-2U [M. W. Binderbauer et al., Phys. Plasmas 22, 056110 (2015)] confinement vessel to increase the flux confinement time of the system. The 0.5 in. stainless steel vessel wall has a skin time of ∼5 ms. The addition of the external copper coils effectively increases this time to ∼7 ms. This led to better-confined/longer-lived field-reversed configuration (FRC) plasmas. The fringing fields generated by the external coils have the side effect of rendering external field measurements invalid. Such measurements were key to the previous method of excluded flux calculation [M. C. Thompson et al., Rev. Sci. Instrum. 83, 10D709 (2012)]. A new array of B-dot probes and Rogowski coils were installed to better determine the amount of flux leaked out of the system and ultimately provide a more robust measurement of plasma parameters related to pressure balance including the excluded flux radius. The B-dot probes are surface mountable chip inductors with inductance of 33 μH capable of measuring the DC magnetic field and transient field, due to resistive current decay in the wall/coils, when coupled with active integrators. The Rogowski coils measure the total change in current in each external coil (150 A/2 ms). Currents were also actively driven in the external coils. This renders the assumption of total flux conservation invalid which further complicates the analysis process. The ultimate solution to these issues and the record breaking resultant FRC lifetimes will be presented.
Thimm, Andreas; Funke, Klaus
2015-01-01
Cortical sensory processing varies with cortical state and the balance of inhibition to excitation. Repetitive transcranial magnetic stimulation (rTMS) has been shown to modulate human cortical excitability. In a rat model, we recently showed that intermittent theta-burst stimulation (iTBS) applied to the corpus callosum, to activate primarily supragranular cortical pyramidal cells but fewer subcortical neurons, strongly reduced the cortical expression of parvalbumin (PV), indicating reduced activity of fast-spiking interneurons. Here, we used the well-studied rodent barrel cortex system to test how iTBS and continuous TBS (cTBS) modulate sensory responses evoked by either single or double stimuli applied to the principal (PW) and/or adjacent whisker (AW) in urethane-anaesthetized rats. Compared to sham stimulation, iTBS but not cTBS particularly enhanced late (>18 ms) response components of multi-unit spiking and local field potential responses in layer 4 but not the very early response (<18 ms). Similarly, only iTBS diminished the suppression of the second response evoked by paired PW or AW–PW stimulation at 20 ms intervals. The effects increased with each of the five iTBS blocks applied. With cTBS a mild effect similar to that of iTBS was first evident after 4–5 stimulation blocks. Enhanced cortical c-Fos and zif268 expression but reduced PV and GAD67 expression was found only after iTBS, indicating increased cortical activity due to lowered inhibition. We conclude that iTBS but less cTBS may primarily weaken a late recurrent-type cortical inhibition mediated via a subset of PV+ interneurons, enabling stronger late response components believed to contribute to the perception of sensory events. PMID:25504571
DOE Office of Scientific and Technical Information (OSTI.GOV)
Roche, T., E-mail: troche@trialphaenergy.com; Thompson, M. C.; Mendoza, R.
2016-11-15
External flux conserving coils were installed onto the exterior of the C-2U [M. W. Binderbauer et al., Phys. Plasmas 22, 056110 (2015)] confinement vessel to increase the flux confinement time of the system. The 0.5 in. stainless steel vessel wall has a skin time of ∼5 ms. The addition of the external copper coils effectively increases this time to ∼7 ms. This led to better-confined/longer-lived field-reversed configuration (FRC) plasmas. The fringing fields generated by the external coils have the side effect of rendering external field measurements invalid. Such measurements were key to the previous method of excluded flux calculation [M.more » C. Thompson et al., Rev. Sci. Instrum. 83, 10D709 (2012)]. A new array of B-dot probes and Rogowski coils were installed to better determine the amount of flux leaked out of the system and ultimately provide a more robust measurement of plasma parameters related to pressure balance including the excluded flux radius. The B-dot probes are surface mountable chip inductors with inductance of 33 μH capable of measuring the DC magnetic field and transient field, due to resistive current decay in the wall/coils, when coupled with active integrators. The Rogowski coils measure the total change in current in each external coil (150 A/2 ms). Currents were also actively driven in the external coils. This renders the assumption of total flux conservation invalid which further complicates the analysis process. The ultimate solution to these issues and the record breaking resultant FRC lifetimes will be presented.« less
Aboul-Enein, Fahmy; Krssák, Martin; Höftberger, Romana; Prayer, Daniela; Kristoferitsch, Wolfgang
2010-07-20
Reduced N-acetyl-aspartate (NAA) levels in magnetic resonance spectroscopy (MRS) may visualize axonal damage even in the normal appearing white matter (NAWM). Demyelination and axonal degeneration are a hallmark in multiple sclerosis (MS). To define the extent of axonal degeneration in the NAWM in the remote from focal lesions in patients with relapsing-remitting (RRMS) and secondary progressive MS (SPMS). 37 patients with clinical definite MS (27 with RRMS, 10 with SPMS) and 8 controls were included. We used 2D (1)H-MR-chemical shift imaging (TR = 1500ms, TE = 135ms, nominal resolution 1ccm) operating at 3Tesla to assess the metabolic pattern in the fronto-parietal NAWM. Ratios of NAA to creatine (Cr) and choline (Cho) and absolute concentrations of the metabolites in the NAWM were measured in each voxel matching exclusively white matter on the anatomical T2 weighted MR images. No significant difference of absolute concentrations for NAA, Cr and Cho or metabolite ratios were found between RRMS and controls. In SPMS, the NAA/Cr ratio and absolute concentrations for NAA and Cr were significantly reduced compared to RRMS and to controls. In our study SPMS patients, but not RRMS patients were characterized by low NAA levels. Reduced NAA-levels in the NAWM of patients with MS is a feature of progression.
Magnetic resonance imaging as a surrogate outcome for multiple sclerosis relapses
Petkau, J; Reingold, SC; Held, U; Cutter, GR; Fleming, TR; Hughes, MD; Miller, DH; McFarland, HF; Wolinsky, JS
2009-01-01
Background Magnetic resonance imaging (MRI) of lesions in the brain may be the best current candidate for a surrogate biological marker of clinical outcomes in relapsing remitting multiple sclerosis (MS), based on its role as an objective indicator of disease pathology. No biological surrogate marker has yet been validated for MS clinical outcomes. Objective The objective of this study was to use a multi-phased study to determine if a valid surrogate relationship could be demonstrated between counts of contrast enhancing lesions (CELs) and occurrence of relapses in MS. Methods We examined correlations for the concurrent and predictive relationship between CELs over 6 months and MS relapses over the same 6 months and an additional 6 months (total: 12 months), using available data on untreated patients from a large clinical trial and natural history database. Results Concurrent and predictive correlations were inadequate to justify continuation of this study to the planned additional phases required to demonstrate a surrogate relationship between CELs and MS relapses. Conclusions Confidence intervals for correlations between CELs and MS relapses exclude the possibility that CELs can be a good surrogate for relapses over the time scales we investigated. Further exploration of surrogacy between MRI measures and MS clinical outcomes may require improved datasets, the development of MRI techniques that couple better to clinical disease, and the ability to test a wide range of imaging- and clinically-based hypotheses for surrogacy. PMID:18535021
Jeong, Arong; Lim, H B
2018-02-01
In this work, a magnetophoretic separation ICP-MS immunoassay using newly synthesized multicore magnetic nanoparticles (MMNPs) was developed for the determination of salmonella typhimurium (typhi). The uniqueness of this method was the use of MMNPs doped with Cs for both separation and detection, which enable us to achieve fast analysis, high sensitivity, and good reliability. For demonstration, heat-killed typhi in a phosphate buffer solution was determined by ICP-MS after the MMNP-typhi reaction product was separated from unreacted MMNPs in a micropipette tip filled with 25% polyethylene glycol through magnetophoretic separation. The calibration curve obtained by plotting 133 Cs intensity vs. the number of synthetic standard, showed a coefficient of determination (R 2 ) of 0.94 with a limit of detection (LOD) of 102 cells/mL without cell culturing. Excellent recoveries, between 98-100%, were obtained from four replicates and compared with a sandwich-type ICP-MS immunoassay for further confirmation. Copyright © 2017 Elsevier B.V. All rights reserved.
NASA Astrophysics Data System (ADS)
Gonzalez-Fuentes, C.; Dumas, R. K.; García, C.
2018-01-01
A theoretical and experimental study of the influence of small offsets of the magnetic field (δH) on the measurement accuracy of the spectroscopic g-factor (g) and saturation magnetization (Ms) obtained by broadband ferromagnetic resonance (FMR) measurements is presented. The random nature of δH generates systematic and opposite sign deviations of the values of g and Ms with respect to their true values. A δH on the order of a few Oe leads to a ˜10% error of g and Ms for a typical range of frequencies employed in broadband FMR experiments. We propose a simple experimental methodology to significantly minimize the effect of δH on the fitted values of g and Ms, eliminating their apparent dependence in the range of frequencies employed. Our method was successfully tested using broadband FMR measurements on a 5 nm thick Ni80Fe20 film for frequencies ranging between 3 and 17 GHz.
Khotanlou, Hassan; Afrasiabi, Mahlagha
2012-10-01
This paper presents a new feature selection approach for automatically extracting multiple sclerosis (MS) lesions in three-dimensional (3D) magnetic resonance (MR) images. Presented method is applicable to different types of MS lesions. In this method, T1, T2, and fluid attenuated inversion recovery (FLAIR) images are firstly preprocessed. In the next phase, effective features to extract MS lesions are selected by using a genetic algorithm (GA). The fitness function of the GA is the Similarity Index (SI) of a support vector machine (SVM) classifier. The results obtained on different types of lesions have been evaluated by comparison with manual segmentations. This algorithm is evaluated on 15 real 3D MR images using several measures. As a result, the SI between MS regions determined by the proposed method and radiologists was 87% on average. Experiments and comparisons with other methods show the effectiveness and the efficiency of the proposed approach.
Forouzan, Omid; Warczytowa, Jared; Wieben, Oliver; François, Christopher J; Chesler, Naomi C
2015-12-13
Exercise stress tests are commonly used in clinical settings to monitor the functional state of the heart and vasculature. Large artery stiffness is one measure of arterial function that can be quantified noninvasively during exercise stress. Changes in proximal pulmonary artery stiffness are especially relevant to the progression of pulmonary hypertension (PH), since pulmonary artery (PA) stiffness is the best current predictor of mortality from right ventricular failure. Cardiovascular magnetic resonance (CMR) was used to investigate the effect of exercise stress on PA pulse wave velocity (PWV) and relative area change (RAC), which are both non-invasive measures of PA stiffness, in healthy subjects. All 21 subjects (average age 26 ± 4 years; 13 female and 8 male) used a custom-made MR-compatible stepping device to exercise (two stages of mild-to-moderate exercise of 3-4 min duration each) in a supine position within the confines of the scanner. To measure the cross-sectional area and blood flow velocity in the main PA (MPA), two-dimensional phase-contrast (2D-PC) CMR images were acquired. To measure the reproducibility of metrics, CMR images were analyzed by two independent observers. Inter-observer agreements were calculated using the intraclass correlation and Bland-Altman analysis. From rest to the highest level of exercise, cardiac output increased from 5.9 ± 1.4 L/min to 8.2 ± 1.9 L/min (p < 0.05), MPA PWV increased from 1.6 ± 0.5 m/s to 3.6 ± 1.4 m/s (p < 0.05), and MPA RAC decreased from 0.34 ± 0.11 to 0.24 ± 0.1 (p < 0.05). While PWV also increased from the first to second exercise stage (from 2.7 ± 1.0 m/s to 3.6 ± 1.4 m/s, p < 0.05), there was no significant change in RAC between the two exercise stages. We found good inter-observer agreement for quantification of MPA flow, RAC and PWV. These results demonstrate that metrics of MPA stiffness increase in response to acute moderate exercise in healthy subjects and that CMR exercise stress offers great potential in clinical practice to noninvasively assess vascular function.
Thermal and temporal evolution of microstructure in polycrystalline ZnO
DOE Office of Scientific and Technical Information (OSTI.GOV)
Kondal, Neha; Tiwari, Sanjiv Kumar, E-mail: sanjivkumar.tiwari@juit.ac.in
2016-05-06
Tug between electronics and spintronics has opened up new area of research named as dilute magnetic semiconductors (DMS), ZnO is one of the most reliable candidates for spintronic devices and DMS. Since, pure and transition metal doped polycrystalline ZnO shows room temperature ferromagnetism, therefore it is very important to gain insight into its microstructure (MS) evolution. We report thermal evolution of MS of pure ZnO on sintering it at 200 °C, 400 °C, 600 °C, and 800 °C in ambient atmosphere for two hours. Temporal evolution at fixed temperature was analyzed using mean field model of internal energy and entropy.more » Grain size of ZnO MS were analyzed using integral breadth method of X-ray diffraction (XRD) lines using Voigt profile fit,. XRD line corresponding to [101] plane shifts from 36.17° to 36.28° whereas grain size increases from 67.5 nm to 93.7 nm with increase of temperature from 23°C to 800°C respectively. Grain growth with increase of temperature show Arrhenius type behavior with activation energy of 30.77 kJ-mol{sup −1} and temporal growth shows diffusive behavior with exponent 0.5.« less
Guo, Zhongxian; Liu, Ying; Li, Shuping; Yang, Zhaoguang
2009-12-01
Identification of microbial contaminants in drinking water is a challenge to matrix-assisted laser desorption/ionization mass spectrometry (MALDI-MS) due to low levels of microorganisms in fresh water. To avoid the time-consuming culture step of obtaining enough microbial cells for subsequent MALDI-MS analysis, a combination of membrane filtration and nanoparticles- or microparticles-based magnetic separation is a fast and efficient approach. In this work, the interaction of bacteria and fluidMAG-PAA, a cation-exchange superparamagnetic nanomaterial, was investigated by MALDI-MS analysis and transmission electron microscopy. FluidMAG-PAA selectively captured cells of Salmonella, Bacillus, Enterococcus and Staphylococcus aureus. This capture was attributed to the aggregation of negatively charged nanoparticles on bacterial cell regional surfaces that bear positive charges. Three types of non-porous silica-encapsulated anion-exchange magnetic microparticles (SiMAG-Q, SiMAG-PEI, SiMAG-DEAE) were capable of concentrating a variety of bacteria, and were compared with silica-free, smaller fluidMAG particles. Salmonella, Escherichia coli, Enterococcus and other bacteria spiked in aqueous solutions, tap water and reservoir water were separated and concentrated by membrane filtration and magnetic separation based on these ion-exchange magnetic materials, and then characterized by whole cell MALDI-MS. By comparing with the mass spectra of the isolates and pure cells, bacteria in fresh water can be rapidly detected at 1 x 10(3) colony-forming units (cfu)/mL. Copyright 2009 John Wiley & Sons, Ltd.
Wu, Kesheng; Guo, Liang; Xu, Wei; Xu, Hengyi; Aguilar, Zoraida P; Xu, Guomao; Lai, Weihua; Xiong, Yonghua; Wan, Yiqun
2014-11-01
A magnetic solid-phase extraction method (MSPE) was developed to pre-concentrate and cleanup clenbuterol (CLE) from pork muscle. Novel sulfonated polystyrene magnetic nanobeads (spMNBs) were synthesized via a one-pot emulsion copolymerization method by using divinylbenzene, styrene, and sodium styrene sulfonate in the presence of oleic acid-modified and 10-undecylenic acid-modified magnetic ferrofluid. The resulting spMNBs exhibited high adsorption efficiency for CLE and for 10 other common beta-adrenergic agonists, namely, brombuterol, ractopamine, tulobuterol, bambuterol, cimbuterol, mabuterol, clorprenaline, penbutolol, salbutamol, and cimaterol. The adsorption behavior of the spMNBs for CLE was described by the Langmuir equation with a maximum adsorption capacity of 0.41 mg/g. Under the optimized parameters, the extraction of CLE from 0.5 g of pork muscle required 25mg of the spMNBs at a shortened adsorption time (0.5 min). The proposed MSPE was coupled with colloidal gold nanoparticle-based immunochromatographic assay (MSPE-AuNPIA) for the quantitative detection of CLE residue in pork muscle. The limit of detection and limit of quantification for the pork muscle were 0.10 and 0.24 ng/g, respectively. The intra-day and inter-day assay recoveries at three CLE spiked concentrations ranged from 92.5% to 98.1%, with relative standard deviations ranging from 3.2% to 13.0%. The results of MSPE-AuNPIA were confirmed by liquid chromatography-tandem mass spectrometry (LC-MS/MS). The CLE values obtained with MSPE-AuNPIA agreed with those obtained with LC-MS/MS. Copyright © 2014 Elsevier B.V. All rights reserved.
Accelerated Radiation-Damping for Increased Spin Equilibrium (ARISE)
Huang, Susie Y.; Witzel, Thomas; Wald, Lawrence L.
2008-01-01
Control of the longitudinal magnetization in fast gradient echo sequences is an important factor enabling the high efficiency of balanced Steady State Free Precession (bSSFP) sequences. We introduce a new method for accelerating the return of the longitudinal magnetization to the +z-axis that is independent of externally applied RF pulses and shows improved off-resonance performance. The Accelerated Radiation damping for Increased Spin Equilibrium (ARISE) method uses an external feedback circuit to strengthen the Radiation Damping (RD) field. The enhanced RD field rotates the magnetization back to the +z-axis at a rate faster than T1 relaxation. The method is characterized in gradient echo phantom imaging at 3T as a function of feedback gain, phase, and duration and compared with results from numerical simulations of the Bloch equations incorporating RD. A short period of feedback (10ms) during a refocused interval of a crushed gradient echo sequence allowed greater than 99% recovery of the longitudinal magnetization when very little T2 relaxation has time to occur. Appropriate applications might include improving navigated sequences. Unlike conventional flip-back schemes, the ARISE “flip-back” is generated by the spins themselves, thereby offering a potentially useful building block for enhancing gradient echo sequences. PMID:18956463
Huang, Chaozhang; Hu, Bin
2008-03-01
A new method was developed for the speciation of inorganic tellurium species in seawater by inductively coupled plasma-MS (ICP-MS) following selective magnetic SPE (MSPE) separation. Within the pH range of 2-9, tellurite (Te(IV)) could be quantitatively adsorbed on gamma-mercaptopropyltrimethoxysilane (gamma-MPTMS) modified silica-coated magnetic nanoparticles (MNPs), while the tellurate (Te(VI)) was not retained and remained in solution. Without filtration or centrifugation, these tellurite-loaded MNPs could be separated easily from the aqueous solution by simply applying external magnetic field. The Te(IV) adsorbed on the MNPs could be recovered quantitatively using a solution containing 2 mol/L HCl and 0.03 mol/L K2Cr2O7. Te(VI) was reduced to Te(IV) by L-cysteine prior to the determination of total tellurium, and its assay was based on subtracting Te(IV) from total tellurium. The parameters affecting the separation were investigated systematically and the optimal separation conditions were established. Under the optimal conditions, the LOD obtained for Te(IV) was 0.079 ng/L, while the precision was 7.0% (C = 10 ng/L, n = 7). The proposed method was successfully applied to the speciation of inorganic tellurium in seawater.
Stocke, Nathanael A.; Meenach, Samantha A.; Arnold, Susanne M.; Mansour, Heidi M.; Hilt, J. Zach.
2018-01-01
Targeted pulmonary delivery facilitates the direct application of bioactive materials to the lungs in a controlled manner and provides an exciting platform for targeting magnetic nanoparticles (MNPs) to the lungs. Iron oxide MNPs remotely heat in the presence of an alternating magnetic field (AMF) providing unique opportunities for therapeutic applications such as hyperthermia. In this study, spray drying was used to formulate magnetic nanocomposite microparticles (“MnMs”) consisting of iron oxide MNPs and D-mannitol. The physicochemical properties of these MnMs were evaluated and the in vitro aerosol dispersion performance of the dry powders was measured by the Next Generation Impactor®. For all powders the mass median aerosol diameter (MMAD) was < 5 µm and deposition patterns revealed that MnMs could deposit throughout the lungs. Heating studies with a custom AMF showed that MNPs retain excellent thermal properties after spray drying into composite dry powders, with specific absorption ratios (SAR) >200 W/g, and in vitro studies on a human lung cell line indicated moderate cytotoxicity of these materials. These inhalable composites present a class of materials with many potential applications and pose a promising approach for thermal treatment of the lungs through targeted pulmonary administration of MNPs. PMID:25542988
Imaging in multiple sclerosis: A new spin on lesions.
Bou Fakhredin, Rayan; Saade, Charbel; Kerek, Racha; El-Jamal, Lara; Khoury, Samia J; El-Merhi, Fadi
2016-10-01
This article evaluates the most relevant state-of-the-art magnetic resonance (MR) techniques that are clinically available to investigate multiple sclerosis (MS). The presence of hypo- and hyperintense lesions on T1- and T2-weighted magnetic resonance imaging (MRI) sequences in white matter (WM) is a common finding that is occasionally a diagnostic challenge for the radiologist. The technical requirements and how they may help to understand, classify or follow-up these pathologies are briefly summarized. The gold standard for MS diagnosis is pathological correlation. Yet due to limited availability of biopsy and autopsy material, there is a high demand for imaging as a diagnostic as well as prognostic indicator. With the progress in MRI during the last decade, MRI now plays a leading role in the diagnosis and follow-up of MS. A number of correlative pathological and MR studies have helped to define pathological substrates of MS in focal lesions and normal appearing white matter (NAWM). Vascular spaces mimicking MS lesions have been minimized by the enhanced differentiation of WM and grey (GM) matter parenchyma. The aim of this article is to enhance the current understanding of histopathology and radiological characteristics of MS lesions in space and time. © 2016 The Royal Australian and New Zealand College of Radiologists.
Manganese-enhanced magnetic resonance microscopy of mineralization
Chesnick, I.E.; Todorov, T.I.; Centeno, J.A.; Newbury, D.E.; Small, J.A.; Potter, K.
2007-01-01
Paramagnetic manganese (II) can be employed as a calcium surrogate to sensitize magnetic resonance microscopy (MRM) to the processing of calcium during bone formation. At high doses, osteoblasts can take up sufficient quantities of manganese, resulting in marked changes in water proton T1, T2 and magnetization transfer ratio values compared to those for untreated cells. Accordingly, inductively coupled plasma mass spectrometry (ICP-MS) results confirm that the manganese content of treated cell pellets was 10-fold higher than that for untreated cell pellets. To establish that manganese is processed like calcium and deposited as bone, calvaria from the skull of embryonic chicks were grown in culture medium supplemented with 1 mM MnCl2 and 3 mM CaCl2. A banding pattern of high and low T2 values, consistent with mineral deposits with high and low levels of manganese, was observed radiating from the calvarial ridge. The results of ICP-MS studies confirm that manganese-treated calvaria take up increasing amounts of manganese with time in culture. Finally, elemental mapping studies with electron probe microanalysis confirmed local variations in the manganese content of bone newly deposited on the calvarial surface. This is the first reported use of manganese-enhanced MRM to study the process whereby calcium is taken up by osteoblasts cells and deposited as bone. ?? 2007 Elsevier Inc. All rights reserved.
NASA Astrophysics Data System (ADS)
Ansari, Fatemeh; Sobhani, Azam; Salavati-Niasari, Masoud
2016-03-01
Copper hexaferrite (CuFe12O19) nanostructures were prepared by a simple route utilizing maltose-assisted sol-gel process. The morphology, phase structure, composition and purity of nanostructures can be controlled by type of surfactant and also adjusting the Cu:surfactant, Cu:Fe and Cu:reductant ratios. The bean-shape structures are formed in the absence of the surfactant when the molar ratio of Cu:Fe and Cu:reductant are 1:12 and 1:26, respectively. The agglomerated spherical nanoparticles with diameters ranging from 7 to 20 nm are obtained in the presence of triplex, when ratio of Cu:reductant is 1:26. In the absence of surfactant and also in the presence of triplex, the samples are found to be CuFe12O19. When polymer is used, there are still the peaks of CuFe12O19 and also some boad peaks in XRD patterns, because of the small size and encapsulation of nanostructures with polymer. Magnetic measurments show superparamagnetic behavior for the all samples. The Ms for the samples obtained in the presence of polymer shows that the coating of magnetic nanostructures does not always increase Ms. FT-IR frequency bands in the range 463-626, 607 and 542 cm-1 correspond to the formation of metal oxides in ferrites.
Kallaur, Ana Paula; Lopes, Josiane; Oliveira, Sayonara Rangel; Simão, Andrea Name Colado; Reiche, Edna Maria Vissoci; de Almeida, Elaine Regina Delicato; Morimoto, Helena Kaminami; de Pereira, Wildea Lice Carvalho Jennings; Alfieri, Daniele Frizon; Borelli, Sueli Donizete; Kaimen-Maciel, Domacio Ramon; Maes, Michael
2016-10-01
There is evidence that activated immune-inflammatory and oxidative and nitrosative stress (IO&NS) pathways play a role in the pathophysiology of multiple sclerosis (MS) and depression. This study examines serum levels of interleukin (IL)-1β, IL-4, IL-6, and IL-10; peroxides (LOOH); nitric oxide metabolites (NOx); albumin; ferritin; C-reactive protein (CRP); and tumor necrosis factor (TNF)-β NcoI polymorphism (rs909253) and gadolinium-enhanced magnetic resonance imaging (MRI) scan in MS patients with (n = 42) and without (n = 108) depression and normal controls (n = 249). Depression is scored using the depressive subscale of the Hospital Anxiety and Depression Scale (HADS). The extent of neurological disability is measured using the Expanded Disability Status Scale (EDSS) at the same time of the abovementioned measurements and 5 years earlier. Disease progression is assessed as actual EDSS-EDSS 5 years earlier. Three variables discriminate MS patients with depression from those without depression, i.e., increased IL-6 and lower IL-4 and albumin. Binary logistic regression showed that MS with depression (versus no depression) was characterized by more gastrointestinal symptoms and disease progression, higher serum IL-6, and lower albumin levels. In subjects with MS, the HADS score was significantly predicted by three EDSS symptoms, i.e., pyramidal, gastrointestinal, and visual symptoms. Fifty-eight percent of the variance in the HADS score was predicted by gastrointestinal symptoms, visual symptoms, the TNFB1/B2 genotype, and contrast enhancement (both inversely associated). There were no significant associations between depression in MS and type of MS, duration of illness, age, sex, nicotine dependence, and body mass index. MS with depression is associated with signs of peripheral inflammation, more disability, disease progression, gastrointestinal and visual symptoms, but less contrast enhancement as compared to MS without depression. It is concluded that depression is part of the neurological symptoms of MS and that its expression is primed by peripheral inflammation while acute neuroinflammation and the TNFB1/B2 genotype may be protective.
Evans, P; Fairman, B
2001-10-01
Reliable trace metal analysis of environmental samples is dependent upon the availability of high accuracy, matrix reference standards. Here, we present Cd, Cu, Ni, Pb and Zn isotope dilution determination for an estuary water certified reference material (LGC 6016). This work highlights the need for high-accuracy techniques in the development of trace element CRMs rather than conventional inter-laboratory trials. Certification of the estuary water LGC6016 was initially determined from a consensus mean from 14 laboratories but this was found to be unsatisfactory due to the large discrepancies in the reported concentrations. The material was re-analysed using isotope dilution ICP-MS techniques. Pb and Cd were determined using a conventional quadrupole ICP-MS (Elan 5000). Cu, Zn and Ni were determined using a magnetic sector ICP-MS (Finnigan Element), which allowed significant polyatomic interferences to be overcome. Using the magnetic sector instrument, precise mass calibration to within 0.02 amu permitted identification of the interferences. Most interferences derived from the sample matrix. For example, the high Na content causes interferences on 63Cu, due to the formation of 40Ar23Na and 23Na2 16O1H, which in a conventional quadrupole instrument would relate to an erroneous increase in signal intensity by up to 20%. For each analyte a combined uncertainty calculation was performed following the Eurachem/GTAC and ISO guideline. For each element a combined uncertainty of 2-3% was found, which represents a 10-fold improvement compared to certification by inter-laboratory comparison. Analysis of the combined uncertainty budget indicates that the majority of systematic uncertainty derives from the instrumental isotope ratio measurements.
Xu, Fei; Liu, Feng; Wang, Chaozhan; Wei, Yinmao
2018-02-01
In this study, the strategy of unique adsorbent combined with isotope labeled internal standards was used to significantly reduce the matrix effect for the enrichment and analysis of nine fluoroquinolones in a complex sample by liquid chromatography coupled to quadrupole linear ion trap mass spectrometry (LC-QqQ LIT -MS/MS). The adsorbent was prepared conveniently by functionalizing Fe 3 O 4 @SiO 2 microspheres with phenyl and tetrazolyl groups, which could adsorb fluoroquinolones selectively via hydrophobic, electrostatic, and π-π interactions. The established magnetic solid-phase extraction (MSPE) method as well as using stable isotope labeled internal standards in the next MS/MS detection was able to reduce the matrix effect significantly. In the process of LC-QqQ LIT -MS/MS analysis, the precursor and product ions of the analytes were monitored quantitatively and qualitatively on a QTrap system equipped simultaneously with the multiple reaction monitoring (MRM) and enhanced product ion (EPI) scan. Subsequently, the enrichment method combined with LC-QqQ LIT -MS/MS demonstrated good analytical features in terms of linearity (7.5-100.0 ng mL -1 , r > 0.9960), satisfactory recoveries (88.6%-118.3%) with RSDs < 12.0%, LODs = 0.5 μg kg -1 and LOQs = 1.5 μg kg -1 for all tested analytes. Finally, the developed MSPE-LC-QqQ LIT -MS/MS method had been successfully applied to real pork samples for food-safety risk monitoring in Ningxia Province, China. Graphical abstract Mechanism of reducing matrix effect through the as-prepared adsorbent.
Effect of Y addition on crystallization behavior and soft-magnetic properties of Fe78Si9B13 ribbons
NASA Astrophysics Data System (ADS)
Zhanwei, Liu; Dunbo, Yu; Kuoshe, Li; Yang, Luo; Chao, Yuan; Zilong, Wang; Liang, Sun; Kuo, Men
2017-08-01
A series of amorphous Fe-Si-B ribbons with various Y addition were prepared by melt-spinning. The effect of Y addition on crystallization behavior, thermal and magnetic properties was systematically investigated. With the increase of Y content, the initial crystallization temperature shifted to a higher temperature, indicating that the thermal stability of amorphous state in Fe-Si-B-Y ribbon is enhanced compared to that of Fe-Si-B alloy. Meanwhile, compared to the two exothermic peaks in the samples with lower Y content, a new exothermic peak was found in the ribbons with Y content higher than 1 at%, which corresponded to the decomposition of metastable Fe3B phase. Among all the alloys, Fe76.5Si9B13Y1.5 alloy exhibits optimized magnetic properties, with high saturation magnetization Ms of 187 emu/g and low coercivity HcJ of 7.6 A/m.
Evolution of structural, magnetic and transport behavior by Pr doping in SrRuO3
NASA Astrophysics Data System (ADS)
Gupta, Renu; Pramanik, A. K.
2018-05-01
Here we report the evolution of structural, magnetic and transport behavior in perovskite based ruthenates Sr1-xPrxRuO3 (x=0.0 and 0.1). The substitution of Pr on Sr site retains orthorhombic structure while we find the slight change in structural parameters. The SrRuO3 has itinerant ferromagnet (FM) type nature of ordering temperature ˜160 K and below the transition temperature showing large bifurcation between ZFC and FC magnetization. By Pr doping, the magnetic moment decreases with decreasing bifurcation of ZFC and FC. The ZFC data show three distinct peaks (three transition temperature; TM1,TM2 and TM3). The magnetization study of both the samples, at high temperature fitted with modified CWL showing the decreasing value of ordering temperature by Pr doping matches close to TM2. The low-temperature isothermal magnetization M (H) data show that the high field saturation moment has decreased by Pr doping. The Arrott plot gives spontaneous magnetization (Ms) which is also decreased by Pr substitution. Evolution of Rhodes-Wohlfarth ratio value increases, which suggests that FM in this system evolves toward the more itinerant type by Pr doping. The electrical resistivity ρ(T) of both the samples show metallic behavior, in the all temperature range and ρ(T) increases by Pr doping while around below 45 K, the resistivity decreases by Pr doping and this crossing temperature also matches with ZFC data.
Ultra-Low Field SQUID-NMR using LN2 Cooled Cu Polarizing Field coil
NASA Astrophysics Data System (ADS)
Demachi, K.; Kawagoe, S.; Ariyoshi, S.; Tanaka, S.
2017-07-01
We are developing an Ultra-Low Field (ULF) Magnetic Resonance Imaging (MRI) system using a High-Temperature Superconductor superconducting quantum interference device (HTS rf-SQUID) for food inspection. The advantages of the ULF-NMR (Nuclear Magnetic Resonance) / MRI as compared with a conventional high field MRI are that they are compact and of low cost. In this study, we developed a ULF SQUID-NMR system using a polarizing coil to measure fat of which relaxation time T1 is shorter. The handmade polarizing coil was cooled by liquid nitrogen to reduce the resistance and accordingly increase the allowable current. The measured decay time of the polarizing field was 40 ms. The measurement system consisted of the liquid nitrogen cooled polarizing coil, a SQUID, a Cu wound flux transformer, a measurement field coil for the field of 47 μT, and an AC pulse coil for a 90°pulse field. The NMR measurements were performed in a magnetically shielded room to reduce the environmental magnetic field. The size of the sample was ϕ35 mm × L80 mm. After applying a polarizing field and a 90°pulse, an NMR signal was detected by the SQUID through the flux transformer. As a result, the NMR spectra of fat samples were obtained at 2.0 kHz corresponding to the measurement field Bm of 47 μT. The T1 relaxation time of the mineral oil measured in Bm was 45 ms. These results suggested that the ULF-NMR/MRI system has potential for food inspection.
NASA Technical Reports Server (NTRS)
Spektor, R.; Tighe, W. G.; Kamhawi, H.
2016-01-01
A set of Laser Induced Fluorescence (LIF) measurements in the near-field region of the NASA- 173M Hall thruster plume is presented at four background pressure conditions varying from 9.4 x 10(exp -6) torr to 3.3 x 10(exp -5) torr. The xenon ion velocity distribution function was measured simultaneously along the axial and radial directions. An ultimate exhaust velocity of 19.6+/-0.25 km/s achieved at a distance of 20 mm was measured, and that value was not sensitive to pressure. On the other hand, the ion axial velocity at the thruster exit was strongly influenced by pressure, indicating that the accelerating electric field moved inward with increased pressure. The shift in electric field corresponded to an increase in measured thrust. Pressure had a minor effect on the radial component of ion velocity, mainly affecting ions exiting close to the channel inner wall. At that radial location the radial component of ion velocity was approximately 1000 m/s greater at the lowest pressure than at the highest pressure. A reduction of the inner magnet coil current by 0.6 A resulted in a lower axial ion velocity at the channel exit while the radial component of ion velocity at the channel inner wall location increased by 1300 m/s, and at the channel outer wall location the radial ion velocity remained unaffected. The ultimate exhaust velocity was not significantly affected by the inner magnet current.
Xu, Yuan; Peng, Shixiang; Ren, Haitao; Zhao, Jie; Chen, Jia; Zhang, Ailin; Zhang, Tao; Guo, Zhiyu; Chen, Jia'er
2014-02-01
The permanent magnet 2.45 GHz electron cyclotron resonance ion source at Peking University can produce more than 100 mA hydrogen ion beam working at pulsed mode. For the increasing requirements of cluster ions (H2(+) and H3(+)) in linac and cyclotron, experimental study was carried out to further understand the hydrogen plasma processes in the ion source for the generation of cluster ions. The constituents of extracted beam have been analyzed varying with the pulsed duration from 0.3 ms to 2.0 ms (repetition frequency 100 Hz) at different operation pressure. The fraction of cluster ions dramatically increased when the pulsed duration was lower than 0.6 ms, and more than 20 mA pure H3(+) ions with fraction 43.2% and 40 mA H2(+) ions with fraction 47.7% were obtained when the operation parameters were adequate. The dependence of extracted ion fraction on microwave power was also measured at different pressure as the energy absorbed by plasma will greatly influence electron temperature and electron density then the plasma processes in the ion source. More details will be presented in this paper.
Enhancement of switching stability of tunneling magnetoresistance system with artificial ferrimagnet
NASA Astrophysics Data System (ADS)
You, Chun-Yeol; Bader, Sam. D.; Scheinfein, M. R.
2002-03-01
In the study of spin dependent magnetic tunneling junctions, the switching stability of the magnetically hard layer is a crucial issue in magnetic random access memory applications[1]. After repeated cycling of the soft layer, the magnetization of the hard layer is demagnetized by the stray field from the domain wall created during the switching[2]. The magnitude of the stray field from the soft layer is large enough to switch a domain in the hard layer. Therefore, reducing this stray field is necessary to increase the switching stability. In this study, we explore an artificial ferrimagnet to replace the usual soft layer in order to reduce stray field. The ferrimagnet consists of an antiferromagnetically coupled trilayer that has two ferromagnetic layers of unequal thickness and opposite magnetization orientation. Since the sign of stray field of the two ferromagnetic layers is opposed, the total stray field is greatly reduced. [Supported by the US DOE, BES-MS, under Contract W-31-109-ENG-38.] [1] S. Gider et al. Science 281, 797 (1998). [2] L. Thomas et al. Phys. Rev. Lett. 84, 1816 (2000).
Malginov, Vladimir A; Malginov, Andrey V; Fleishman, Leonid S
2013-01-01
The quench process in high-temperature superconducting (HTS) wires plays an important role in superconducting power devices, such as fault current limiters, magnets, cables, etc. The superconducting device should survive after the overheating due to quench. We studied the evolution of the resistance of the YBCO tape wire during the quench process with 1 ms time resolution for various excitation voltages. The resistive normal zone was found to be located in a domain of about 1-4 cm long. The normal state nucleation begins in 40-60 ms after voltage is applied across the HTS tape. In subsequent 200-300 ms other normal state regions appear. The normal domain heating continues in the following 5-10s that results in a factor of 2-3 increase of its resistance. Formation of the normal domain during the quench process follows the same stages for different excitation voltages. Characteristic domain sizes, lifetimes and temperatures are determined for all stages.
MRI CRITERIA FOR THE DIAGNOSIS OF MULTIPLE SCLEROSIS: MAGNIMS CONSENSUS GUIDELINES
Filippi, M.; Rocca, M.A.; Ciccarelli, O.; De Stefano, N.; Evangelou, N.; Kappos, L.; Rovira, A.; Sastre-Garriga, J.; Tintorè, M.; Frederiksen, J.L.; Gasperini, C.; Palace, J.; Reich, D.S.; Banwell, B.; Montalban, X.; Barkhof, F.
2016-01-01
Summary In patients presenting with a clinically isolated syndrome (CIS), magnetic resonance imaging (MRI) can support and substitute clinical information for multiple sclerosis (MS) diagnosis demonstrating disease dissemination in space (DIS) and time (DIT) and helping to rule out other conditions that can mimic MS. From their inclusion in the diagnostic work-up for MS in 2001, several modifications of MRI diagnostic criteria have been proposed, in the attempt to simplify lesion-count models for demonstrating DIS, change the timing of MRI scanning for demonstrating DIT, and increase the value of spinal cord imaging. Since the last update of these criteria, new data regarding the application of MRI for demonstrating DIS and DIT have become available and improvement in MRI technology has occurred. State-of-the-art MRI findings in these patients were discussed in a MAGNIMS workshop, the goal of which was to provide an evidence-based and expert-opinion consensus on diagnostic MRI criteria modifications. PMID:26822746
Functional cardiac magnetic resonance microscopy
NASA Astrophysics Data System (ADS)
Brau, Anja Christina Sophie
2003-07-01
The study of small animal models of human cardiovascular disease is critical to our understanding of the origin, progression, and treatment of this pervasive disease. Complete analysis of disease pathophysiology in these animal models requires measuring structural and functional changes at the level of the whole heart---a task for which an appropriate non-invasive imaging method is needed. The purpose of this work was thus to develop an imaging technique to support in vivo characterization of cardiac structure and function in rat and mouse models of cardiovascular disease. Whereas clinical cardiac magnetic resonance imaging (MRI) provides accurate assessment of the human heart, the extension of cardiac MRI from humans to rodents presents several formidable scaling challenges. Acquiring images of the mouse heart with organ definition and fluidity of contraction comparable to that achieved in humans requires an increase in spatial resolution by a factor of 3000 and an increase in temporal resolution by a factor of ten. No single technical innovation can meet the demanding imaging requirements imposed by the small animal. A functional cardiac magnetic resonance microscopy technique was developed by integrating improvements in physiological control, imaging hardware, biological synchronization of imaging, and pulse sequence design to achieve high-quality images of the murine heart with high spatial and temporal resolution. The specific methods and results from three different sets of imaging experiments are presented: (1) 2D functional imaging in the rat with spatial resolution of 175 mum2 x 1 mm and temporal resolution of 10 ms; (2) 3D functional imaging in the rat with spatial resolution of 100 mum 2 x 500 mum and temporal resolution of 30 ms; and (3) 2D functional imaging in the mouse with spatial resolution down to 100 mum2 x 1 mm and temporal resolution of 10 ms. The cardiac microscopy technique presented here represents a novel collection of technologies capable of acquiring routine high-quality images of murine cardiac structure and function with minimal artifacts and markedly higher spatial resolution compared to conventional techniques. This work is poised to serve a valuable role in the evaluation of cardiovascular disease and should find broad application in studies ranging from basic pathophysiology to drug discovery.
Feature Extraction and Classification of Magnetic and EMI Data, Camp Beale, CA
2012-05-01
and non-specialists. However, as part of ESTCP 1004 we are presently working on transitioning our inversion algorithms to an API that will be...10 0 Time (ms) Cell 663 - Target 1965 - Model 1 (SOI) ISO IVS 0.001 0.005 10 0 Time (ms) Cell 1104 - Target 2532 - Model 1 (SOI) ISO IVS...0.0 1 0.005 10 0 Time (ms) Cell 663 - Target 1965 - Model 1 (SOI) ISO IVS 0.0 1 0.005 10 0 Time (ms) Cell 1104 - Target 2532 - Model 1 (SOI
NASA Astrophysics Data System (ADS)
Yadav, Raghvendra Singh; Kuřitka, Ivo; Vilcakova, Jarmila; Urbánek, Pavel; Machovsky, Michal; Masař, Milan; Holek, Martin
2017-11-01
This paper reports a honey-mediated green synthesis of ZnFe2O4 spinel ferrite nanoparticles and the effect of further annealing on structural, magnetic, optical, dielectric and electrical properties. X-ray diffraction study confirmed the well formation of ZnFe2O4 spinel ferrite crystal structure. Raman and Fourier transform infrared spectroscopy confirmed the formation of spinel ferrite crystal structure. The scanning electron microscopy study revealed the formation of spherical morphology at lower annealing temperature with achieved particle size 30-60 nm, whereas, octahedral like morphology at higher annealing temperature with particle size 50-400 nm. Magnetization measurements were carried out using a vibrating sample magnetometer at room temperature. The estimated magnetic parameter such as saturation magnetization (Ms), remanence (Mr) and coercivity (Hc) showed variation in value with nano-crystallite size. The highest saturation magnetization (Ms) was 12.81 emu/g for as-synthesized ZnFe2O4 spinel ferrite nanoparticles, whereas, highest coercivity (Hc) was 25.77 Oe for ZnFe2O4 nanoparticles annealed at high temperature 1000 °C. UV-Visible reflectance spectroscopy showed the band gap variation from 1.90 eV to 2.14 eV with the increase of annealing temperature. The dielectric constant and dielectric loss were decreased with frequency showing the normal behavior of spinel ferrites. The variation in conductivity is explained in terms of the variation in microstructure and variation in the mobility of charge carriers associated with the cation redistribution induced by annealing or grain size. The modulus and impedance spectroscopy study revealed the influence of bulk grain and the grain boundary on the electrical resistance and capacitance of ZnFe2O4 nanoparticles. The results presented in this work are helpful for green synthesis of well-controlled size, morphology and physical properties of ZnFe2O4 nanoparticles.
Pullen, Anthony E.; Faulmann, Christophe; Pokhodnya, Konstantin I.; Cassoux, Patrick; Tokumoto, Madoka
1998-12-28
A series of metal bis-mnt complexes (mnt = 1,2-dithiolatomaleonitrile) with the trimethylammonium methylferrocene cation have been synthesized and characterized using X-ray diffraction, magnetic susceptibility, and differential scanning calorimetry measurements. The complexes have the formulas (FcCH(2)NMe(3))[Ni(mnt)(2)] (2), (FcCH(2)NMe(3))[Pt(mnt)(2)] (3), and (FcCH(2)NMe(3))(2)[Cu(mnt)(2)] (4) (where Fc = ferrocene). At 300 K, the crystal structures of 1:1 complexes 2 and 3 are very similar. They consist of pairs of [M(mnt)(2)](-) in a slipped configuration packed in stacks. Each [M(mnt)(2)](-) stack is separated from adjacent stacks by two columns of cations. Within the pairs, the [M(mnt)(2)](-) anions interact via short M.S contacts, while there are no short contacts between the pairs. Complex 4, which has a 2:1 stoichiometry, exhibits a markedly different packing arrangement of the anionic units. Due to the special position of the Cu atom in the asymmetric unit cell, [Cu(mnt)(2)](2)(-) dianions are completely isolated from each other. The magnetic susceptibility behavior of the nickel complex is consistent with the presence of magnetically isolated, antiferromagnetically (AF) coupled [Ni(mnt)(2)](-) pairs with the AF exchange parameter, J = -840 cm(-)(1). The platinum complex undergoes an endothermic structural phase transition (T(p)) at 247 K. Below T(p) its structure is characterized by the formation of magnetically isolated [Pt(mnt)(2)](2)(2)(-) dimers in an eclipsed configuration with short Pt.Pt and S.S contacts between monomers. In the magnetic properties, the structural changes reveal themselves as an abrupt susceptibility drop implying a substantial increase of the AF exchange parameter. A mechanism of the phase transition in the platinum compound is proposed. For compound 4, paramagnetic behavior is observed.
NASA Astrophysics Data System (ADS)
Belmeguenai, M.; Roussigné, Y.; Bouloussa, H.; Chérif, S. M.; Stashkevich, A.; Nasui, M.; Gabor, M. S.; Mora-Hernández, A.; Nicholson, B.; Inyang, O.-O.; Hindmarch, A. T.; Bouchenoire, L.
2018-04-01
The interfacial Dzyaloshinskii-Moriya interaction (IDMI) is investigated in Co2FeAl (CFA) ultrathin films of various thicknesses (0.8 nm ≤tCFA≤2 nm ) grown by sputtering on Si substrates, using Pt, W, Ir, and MgO buffer or/and capping layers. Vibrating sample magnetometry reveals that the magnetization at saturation (Ms ) for the Pt- and Ir-buffered films is higher than the usual Ms of CFA due to the proximity-induced magnetization (PIM) in Ir and Pt estimated to be 19% and 27%, respectively. The presence of PIM in these materials is confirmed using x-ray resonant magnetic reflectivity. Moreover, while no PIM is induced in W, higher PIM is obtained with Pt when it is used as a buffer layer rather than a capping layer. Brillouin light scattering in the Damon-Eshbach geometry is used to investigate the thickness dependences of the IDMI constants from the spin-wave nonreciprocity and the perpendicular anisotropy field versus the annealing temperature. The IDMI sign is found to be negative for Pt /CFA and Ir /CFA , while it is positive for W /CFA . The thickness dependence of the effective IDMI constant for stacks involving Pt and W shows the existence of two regimes similar to that of the perpendicular anisotropy constant due to the degradation of the interfaces as the CFA thickness approaches a critical thickness. The surface IDMI and anisotropy constants of each stack are determined for the thickest samples where a linear thickness dependence of the effective IDMI constant and the effective magnetization are observed. The interface anisotropy and IDMI constants investigated for the Pt /CFA /MgO system show different trends with the annealing temperature. The decrease of the IDMI constant with increasing annealing temperature is probably due to the electronic structure changes at the interfaces, while the increase of the interface anisotropy constant is coherent with the interface quality and disorder enhancement.
Towards innovative roadside monitoring
NASA Astrophysics Data System (ADS)
Ojha, G.; Appel, E.; Magiera, T.
2012-04-01
Soil contamination along roadsides is an important factor of anthropogenic point source pollution. Climatic and traffic-specific factors influence the amount and characteristics of pollution emitted and deposited in the roadside soil. In our present study we focus on monitoring typical traffic pollutants (heavy metals HM, platinum group elements, polycyclic hydrocarbons PAH), and investigate the use of magnetic parameters, especially magnetic susceptibility (MS) as proxy. Monitoring plots were installed along roadside in areas with different climatic conditions and different traffic-specific activities (traffic density and speed, vehicle types, abrasion of tires, brake linings, petrol/diesel compounds and road maintenance). For monitoring we removed 10-15 cm of top soil at 1 m distance from the roadside edge and placed 30 plastic boxes there filled with clean quartz sand, to be sampled after regular intervals within two years. Preliminary data from the first year of monitoring are presented. Magnetic results revealed that a coarse grained magnetite-like phase is responsible for the enhancement of magnetic concentration. The mass-specific MS and concentration of pollutants (HM, PAH) all show a significant increase with time, however, there are obviously also seasonal and site-dependent effects which lead to more stable values over several months or even some decrease in the upper few cm due to migration into depth. Source identification indicates that the accumulated PAHs are primarily emissions from traffic. In order to be able to discriminate in between different kinds of transport and deposition (surface run off from the road and neighbouring soil material, splash water, air transport), we additionally established pillars at the roadside with clean quartz sampling boxes at different heights (surface, 0.5 m, 2 m). As a first surprising result we observed that the increase in the boxes at surface is not necessarily higher than at 0.5 m height. The results from our monitoring studies will be utilized to understand site-specific characteristics and to develop new innovative roadside pollution monitoring concepts.
Ku, Yixuan; Zhao, Di; Hao, Ning; Hu, Yi; Bodner, Mark; Zhou, Yong-Di
2015-01-01
Both monkey neurophysiological and human EEG studies have shown that association cortices, as well as primary sensory cortical areas, play an essential role in sequential neural processes underlying cross-modal working memory. The present study aims to further examine causal and sequential roles of the primary sensory cortex and association cortex in cross-modal working memory. Individual MRI-based single-pulse transcranial magnetic stimulation (spTMS) was applied to bilateral primary somatosensory cortices (SI) and the contralateral posterior parietal cortex (PPC), while participants were performing a tactile-visual cross-modal delayed matching-to-sample task. Time points of spTMS were 300 ms, 600 ms, 900 ms after the onset of the tactile sample stimulus in the task. The accuracy of task performance and reaction time were significantly impaired when spTMS was applied to the contralateral SI at 300 ms. Significant impairment on performance accuracy was also observed when the contralateral PPC was stimulated at 600 ms. SI and PPC play sequential and distinct roles in neural processes of cross-modal associations and working memory. Copyright © 2015 Elsevier Inc. All rights reserved.
The importance of magnetic methods for soil mapping and process modelling. Case study in Ukraine
NASA Astrophysics Data System (ADS)
Menshov, Oleksandr; Pereira, Paulo; Kruglov, Oleksandr; Sukhorada, Anatoliy
2016-04-01
The correct planning of agriculture areas is fundamental for a sustainable future in Ukraine. After the recent political problems in Ukraine, new challenges emerged regarding sustainability questions. At the same time the soil mapping and modelling are intensively developing all over the world (Pereira et al., 2015; Brevik et al., in press). Magnetic susceptibility (MS) methods are low cost and accurate for the developing maps of agricultural areas, fundamental for Ukrain's economy.This allow to colleact a great amount of soil data, usefull for a better understading of the spatial distribution of soil properties. Recently, this method have been applied in other works in Ukraine and elsewhere (Jordanova et al., 2011; Menshov et al., 2015). The objective of this work is to study the spatial distribution of MS and humus content on the topsoils (0-5 cm) in two different areas. The first is located in Poltava region and the second in Kharkiv region. The results showed that MS depends of soil type, topography and anthropogenic influence. For the interpretation of MS spatial distribution in top soil we consider the frequency and time after the last tillage, tilth depth, fertilizing, and the puddling regarding the vehicle model. On average the soil MS of the top soil of these two cases is about 30-70×10-8 m3/kg. In Poltava region not disturbed soil has on average MS values of 40-50×10-8 m3/kg, for Kharkiv region 50-60×10-8 m3/kg. The tilled soil of Poltava region has on average an MS of 60×10-8 m3/kg, and 70×10-8 m3/kg in Kharkiv region. MS is higher in non-tilled soils than in the tilled ones. The correlation between MS and soil humus content is very high ( up to 0.90) in both cases. Breivik, E., Baumgarten, A., Calzolari, C., Miller, B., Pereira, P., Kabala, C., Jordán, A. Soil mapping, classification, and modelling: history and future directions. Geoderma (in press), doi:10.1016/j.geoderma.2015.05.017 Jordanova D., Jordanova N., Atanasova A., Tsacheva T., Petrov P., (2011). Soil tillage erosion by using magnetism of soils - a case study from Bulgaria. Environ. Monit. Assess, 183, 381-394. Menshov O. Pereira P., Kruglov O., (2015). Spatial variability of soil magnetic susceptibility in an agricultural field located in Eastern Ukraine. Geophysical Research Abstracts, 17, EGU2015-578-2. Pereira, P., Cerdà, A., Úbeda, X., Mataix-Solera, J. Arcenegui, V., Zavala, L. (2015) Modelling the impacts of wildfire on ash thickness in a short-term period, Land Degradation and Development, 26, 180-192. DOI: 10.1002/ldr.2195
NASA Astrophysics Data System (ADS)
Murtaza, Adil; Yang, Sen; Chang, Tieyan; Ghani, Awais; Khan, Muhammad Tahir; Zhang, Rui; Zhou, Chao; Song, Xiaoping; Suchomel, Matthew; Ren, Yang
2018-03-01
The spin reorientation (SR) and magnetoelastic properties of pseudobinary ferromagnetic T b1 -xN dxC o2 (0 ≤x ≤1.0 ) systems involving a morphotropic phase boundary (MPB) were studied by high-resolution synchrotron x-ray diffraction (XRD), magnetization, and magnetostriction measurements. The easy magnetization direction of the Laves phase lies along the 〈111 〉 axis with x <0.65 , whereas it lies along the 〈100 〉 axis for x >0.65 below Curie temperature (TC). The temperature-dependent magnetization curves showed SR; this can be explained by a two-sublattice model. Based on the synchrotron (XRD) and magnetization measurements, the SR phase diagram for a MPB composition of T b0.35N d0.65C o2 was obtained. Contrary to previously reported ferromagnetic systems involving MPB, the MPB composition of T b0.35N d0.65C o2 exhibits a low saturation magnetization (MS), indicating a compensation of the Tb and Nd magnetic moments at MPB. The anisotropic magnetostriction (λS) first decreased until x =0.8 and then continuously increased in the negative direction with further increase of Nd concentration. The decrease in magnetostriction can be attributed to the decrease of spontaneous magnetostriction λ111 and increase of λ100 with opposite sign to λ111. This paper indicates an anomalous type of MPB in the ferromagnetic T b1 -xN dxC o2 system and provides an active way to design novel functional materials with exotic properties.
NASA Astrophysics Data System (ADS)
Kazemikia, Kaveh; Bonabi, Fahimeh; Asadpoorchallo, Ali; Shokrzadeh, Majid
2015-02-01
In this work, an optimized pulsed magnetic field production apparatus is designed based on a RLC (Resistance/Self-inductance/Capacitance) discharge circuit. An algorithm for designing an optimum magnetic coil is presented. The coil is designed to work at room temperature. With a minor physical reinforcement, the magnetic flux density can be set up to 12 Tesla with 2 ms duration time. In our design process, the magnitude and the length of the magnetic pulse are the desired parameters. The magnetic field magnitude in the RLC circuit is maximized on the basis of the optimal design of the coil. The variables which are used in the optimization process are wire diameter and the number of coil layers. The coil design ensures the critically damped response of the RLC circuit. The electrical, mechanical, and thermal constraints are applied to the design process. A locus of probable magnetic flux density values versus wire diameter and coil layer is provided to locate the optimum coil parameters. Another locus of magnetic flux density values versus capacitance and initial voltage of the RLC circuit is extracted to locate the optimum circuit parameters. Finally, the application of high magnetic fields on carbon nanotube-PolyPyrrole (CNT-PPy) nano-composite is presented. Scanning probe microscopy technique is used to observe the orientation of CNTs after exposure to a magnetic field. The result shows alignment of CNTs in a 10.3 Tesla, 1.5 ms magnetic pulse.
Matejčíková, Z; Mareš, J; Sládková, V; Svrčinová, T; Vysloužilová, J; Zapletalová, J; Kaňovský, P
2017-05-01
Multiple sclerosis (MS) is an inflammatory-demyelinating disease of the central nervous system (CNS). Autoimmune inflammation is common in the early stages of MS and is followed by neurodegenerative processes. The result of these changes is axon and myelin breakdown. The paraclinical examination methods are an important part of the diagnostic process. Magnetic resonance imaging of the brain and the cervical spinal cord and an examination of cerebrospinal fluid (CSF) are common paraclinical examinations. An increasing number of studies deal with CSF and serum levels of biomarkers and their role in MS. We hypothesized that the level of interleukin-8 (IL-8) could be different in MS patients than in controls. These differences may be related to damage of the blood-brain barrier (BBB). BBB damage is quantified by the quotient of albumin (Q-alb). CSF and serum levels of IL-8 were assessed in 102 patients with newly diagnosed MS meeting McDonald's revised diagnostic criteria and in 102 subjects as a control group. We then correlated these results with Q-alb. Levels of IL-8 in CSF were significantly higher in MS patients than in controls (Mann-Whitney U test, p<0.0001). Serum levels of IL-8 were significantly lower in MS patients than in controls (Mann-Whitney U test, p=0.018). Spearman's correlation analysis proved a significant correlation between levels of IL-8 and Q-alb. As the etiology of MS is only partially known, research dealing with biomarkers in MS should continue. Better knowledge of etiology can provide a new perspective, especially for treatment. Copyright © 2017 Elsevier B.V. All rights reserved.
USDA-ARS?s Scientific Manuscript database
A dereplication strategy using a combination of liquid chromatography-mass spectrometry (LC-MS) and proton nuclear magnetic resonance spectroscopy (1H NMR) to facilitate compound identification towards antifungal natural product discovery is presented. This analytical approach takes advantage of th...
Temperature dependence of LRE-HRE-TM thin films
NASA Astrophysics Data System (ADS)
Li, Zuoyi; Cheng, Xiaomin; Lin, Gengqi; Li, Zhen; Huang, Zhixin; Jin, Fang; Wang, Xianran; Yang, Xiaofei
2003-04-01
Temperature dependence of the properties of RE-TM thin films is very important for MO recording. In this paper, we studied the temperature dependence of the magnetic and magneto-optical properties of the amorphous LRE-HRE-TM single layer thin films and LRE-HRE-TM/HRE-TM couple-bilayered thin films. For LRE-HRE-TM single layer thin films, the temperature dependence of the magnetization was investigated by using the mean field theory. The experimental and theoretical results matched very well. With the LRE substitution in HRE-TM thin film, the compensation temperature Tcomp decreased and the curie temperature Tc remained unchanged. Kerr rotation angle became larger and the saturation magnetization Ms at room temperature increased. For LRE-HRE-TM/HRE-TM couple-bilayered thin films, comparisons of the temperature dependences of the coercivities and Kerr rotation angles were made between isolated sublayers and couple-bilayered thin film.
NASA Astrophysics Data System (ADS)
Palihawadana Arachchige, Maheshika; Nemala, Humeshkar; Naik, Vaman; Naik, Ratna
Magnetic hyperthermia (MHT) has a great potential as a non-invasive cancer therapy technique. Specific absorption rate (SAR) which measures the efficiency of heat generation, mainly depends on magnetic properties of nanoparticles such as saturation magnetization (Ms) and magnetic anisotropy (K) which depend on the size and shape. Therefore, MHT applications of magnetic nanoparticles often require a controllable synthesis to achieve desirable magnetic properties. We have synthesized Fe3O4 nanoparticles using two different methods, co-precipitation (CP) and hydrothermal (HT) techniques to produce similar XRD crystallite size of 12 nm, and subsequently coated with dextran to prepare ferrofluids for MHT. However, TEM measurements show average particle sizes of 13.8 +/-3.6 nm and 14.6 +/-3.6 nm for HT and CP samples, implying the existence of an amorphous surface layer for both. The MHT data show the two samples have very different SAR values of 110 W/g (CP) and 40W/g (HT) at room temperature, although they have similar Ms of 70 +/-4 emu/g regardless of their different TEM sizes. We fitted the temperature dependent SAR using linear response theory to explain the observed results. CP sample shows a larger magnetic core with a narrow size distribution and a higher K value compared to that of HT sample.
NASA Astrophysics Data System (ADS)
Motavallian, Pourya; Abasht, Behzad; Abdollah-Pour, Hassan
2018-04-01
Nanocrystalline CoZrxFe2-xO4 (0 ≤ x ≤ 0.3 in a step of 0.05) powders were synthesized by Pechini sol-gel method. The dry gel was grinded and calcined at 700 °C in a static air atmosphere for 1 h. Some tests such as thermo gravimetric analysis (TGA) combined with differential analysis (DTA), fourier transform infrared spectroscopy (FTIR), X-ray diffraction (XRD), field emission scanning electron microscopy (FE-SEM) and vibrating sample magnetometer (VSM) were carried out to investigate the thermal behaviour, structural bonds identification, crystallographic properties, morphology and magnetic properties of the obtained powders. X-ray diffraction revealed a single-phase cubic spinel structure for all samples, where the crystallite size decreases; the lattice parameter simultaneously increases with substitution of Zr. The results of FE-SEM showed that the particle size is in the 20-70 nm range. The magnetic properties such as saturation magnetization (Ms), remanent magnetization (Mr) and coercivity (Hc) were measured from the hysteresis loops. The greatest amount of saturation magnetization for CoZr0.05Fe1.95O4 sample was 67.9 emu·g-1.
Heat Transfer to Anode of Arc as Function of Transverse Magnetic Field and Lateral Gas Flow Velocity
NASA Astrophysics Data System (ADS)
Zama, Yoshiyuki; Shiino, Toru; Ishii, Yoko; Maeda, Yoshifumi; Yamamoto, Shinji; Iwao, Toru
2016-10-01
Gas tungsten arc welding has useful joining technology because of high-energy and high-current characteristics. It can be flexible from the transverse magnetic field and lateral gas flow velocity. In this case, the weld defect occurs. In this research, the heat transfer to the anode of the arc as a function of the transverse magnetic field and lateral gas flow velocity is elucidated. That magnetic flux density and lateral gas velocity were varied from 0 to 3 mT and 0 to 50?m?s -1, respectively. The axial plasma gas argon flow rates were 3?slm. A transverse magnetic field is applied to the arc using Helmholtz coil. The anode is used by a water-cooled copper plate, and the heat transfer is measured by temperature of cooled water. As a result, the arc is deflected by the Lorentz force and lateral gas convection. Thus, the heat transfer to the anode of the arc decreases with increasing the transverse magnetic field and lateral gas flow velocity. In addition, the heat transfer to the anode changes with different attachments modes. The lateral gas flow causes a convective heat loss from the arc to the chamber walls.
Topology in Synthetic Column Density Maps for Interstellar Turbulence
NASA Astrophysics Data System (ADS)
Putko, Joseph; Burkhart, B. K.; Lazarian, A.
2013-01-01
We show how the topology tool known as the genus statistic can be utilized to characterize magnetohydrodyanmic (MHD) turbulence in the ISM. The genus is measured with respect to a given density threshold and varying the threshold produces a genus curve, which can suggest an overall ‘‘meatball,’’ neutral, or ‘‘Swiss cheese’’ topology through its integral. We use synthetic column density maps made from three-dimensional 5123 compressible MHD isothermal simulations performed for different sonic and Alfvénic Mach numbers (Ms and MA respectively). We study eight different Ms values each with one sub- and one super-Alfvénic counterpart. We consider sight-lines both parallel (x) and perpendicular (y and z) to the mean magnetic field. We find that the genus integral shows a dependence on both Mach numbers, and this is still the case even after adding beam smoothing and Gaussian noise to the maps to mimic observational data. The genus integral increases with higher Ms values (but saturates after about Ms = 4) for all lines of sight. This is consistent with greater values of Ms resulting in stronger shocks, which results in a clumpier topology. We observe a larger genus integral for the sub-Alfvénic cases along the perpendicular lines of sight due to increased compression from the field lines and enhanced anisotropy. Application of the genus integral to column density maps should allow astronomers to infer the Mach numbers and thus learn about the environments of interstellar turbulence. This work was supported by the National Science Foundation’s REU program through NSF Award AST-1004881.
Prognostic value of free light chains lambda and kappa in early multiple sclerosis.
Voortman, Margarete M; Stojakovic, Tatjana; Pirpamer, Lukas; Jehna, Margit; Langkammer, Christian; Scharnagl, Hubert; Reindl, Markus; Ropele, Stefan; Seifert-Held, Thomas; Archelos, Juan-Jose; Fuchs, Siegrid; Enzinger, Christian; Fazekas, Franz; Khalil, Michael
2017-10-01
Cerebrospinal fluid (CSF) immunoglobulin free light chains (FLC) have been suggested as quantitative alternative to oligoclonal bands (OCB) in the diagnosis of multiple sclerosis (MS). However, little is known on their role in predicting clinical and paraclinical disease progression, particularly in early stages. To assess the prognostic value of FLC in OCB-positive patients with clinically isolated syndrome (CIS) suggestive of MS and early MS. We determined FLC kappa (KFLC) and lambda (LFLC) in CSF and serum by nephelometry in 61 patients (CIS ( n = 48), relapsing-remitting multiple sclerosis ( n = 13)) and 60 non-inflammatory neurological controls. Median clinical follow-up time in CIS was 4.8 years (interquartile range (IQR), 1.5-6.5 years). Patients underwent 3T magnetic resonance imaging (MRI) at baseline and follow-up (median time interval, 2.2 years; IQR, 1.0-3.7 years) to determine T2 lesion load (T2LL) and percent brain volume change (PBVC). CSF FLC were significantly increased in CIS/MS compared to controls (all p < 0.001). A lower KFLC/LFLC CSF ratio was associated with CIS-clinically definite multiple sclerosis (CDMS) conversion (hazard ratio (HR) = 2.89; 95% confidence interval (CI) = 1.17-7.14; p < 0.05). No correlations were found for FLC variables with T2LL or PBVC. Our study confirms increased intrathecal synthesis of FLC in CIS/MS which supports their diagnostic contribution. The KFLC/LFLC CSF ratio appears to have a prognostic value in CIS beyond OCB.
Guzmán-López, Jessica; Selvi, Aikaterini; Solà-Valls, Núria; Casanova-Molla, Jordi; Valls-Solé, Josep
2015-12-01
Modulation of spinal reflexes depends largely on the integrity of the corticospinal tract. A useful method to document the influence of descending tracts on reflexes is to examine the effects of transcranial magnetic stimulation (TMS) on the soleus H reflex elicited by posterior tibial nerve electrical stimuli (PTS). In 12 healthy volunteers, we investigated how postural or voluntary muscle contraction modified such descending modulation. We first characterized the effects of TMS at 95 % of motor threshold for leg responses on the H reflex elicited by a preceding PTS at inter-stimuli intervals (ISIs) between 0 and 120 ms at rest and, then, during voluntary plantar flexion (pf), dorsal flexion (df), and standing still (ss). During pf, there was an increase in the facilitation of the H reflex at ISIs 0-20 ms. During df, there were no effects of TMS on the H reflex. During ss, there was inhibition at ISIs 40-60 ms. Our observations suggest that muscle contraction prevails over the baseline effects of TMS on the soleus H reflex. While contraction of the antagonist (df) suppressed most of the effects, contraction of the agonist had different effects depending on the type of activity (pf or ss). The characterization of the interaction between descending corticospinal volleys and segmental peripheral inputs provides useful information on motor control for physiological research and further understanding of the effects of spinal cord lesions.
NASA Astrophysics Data System (ADS)
Yarmohammadi, Mohsen
2016-12-01
Using the Harrison model and Green's function technique, impurity doping effects on the orbital density of states (DOS), electronic heat capacity (EHC) and magnetic susceptibility (MS) of a monolayer hydrogenated graphene, chair-like graphane, are investigated. The effect of scattering between electrons and dilute charged impurities is discussed in terms of the self-consistent Born approximation. Our results show that the graphane is a semiconductor and its band gap decreases with impurity. As a remarkable point, comparatively EHC reaches almost linearly to Schottky anomaly and does not change at low temperatures in the presence of impurity. Generally, EHC and MS increases with impurity doping. Surprisingly, impurity doping only affects the salient behavior of py orbital contribution of carbon atoms due to the symmetry breaking.
THE EFFECTS OF CLOSE COMPANIONS (AND ROTATION) ON THE MAGNETIC ACTIVITY OF M DWARFS
DOE Office of Scientific and Technical Information (OSTI.GOV)
Morgan, Dylan P.; West, Andrew A.; Dhital, Saurav
2012-10-01
We present a study of close white dwarf and M dwarf (WD+dM) binary systems and examine the effect that a close companion has on the magnetic field generation in M dwarfs. We use a base sample of 1602 white dwarf main-sequence binaries from Rebassa-Mansergas et al. to develop a set of color cuts in GALEX, SDSS, UKIDSS, and 2MASS color space. Then using the SDSS Data Release 8 spectroscopic database, we construct a sample of 1756 WD+dM high-quality pairs from our color cuts and previous catalogs. We separate the individual WD and dM from each spectrum using an iterative techniquemore » that compares the WD and dM components to best-fit templates. Using the absolute height above the Galactic plane as a proxy for age, and the H{alpha} emission line as an indicator for magnetic activity, we investigate the age-activity relation for our sample for spectral types {<=} M7. Our results show that early-type M dwarfs ({<=}M4) in close binary systems are more likely to be active and have longer activity lifetimes compared to their field counterparts. However, at a spectral type of M5 (just past the onset of full convection in M dwarfs), the activity fraction and lifetimes of WD+dM binary systems become more comparable to that of the field M dwarfs. One of the implications of having a close binary companion is presumed to be increased stellar rotation through disk disruption, tidal effects, or angular momentum exchange. Thus, we interpret the similarity in activity behavior between late-type dMs in WD+dM pairs and late-type field dMs to be due to a decrease in sensitivity in close binary companions (or stellar rotation), which has implications for the nature of magnetic activity in fully convective stars. Using the WD components of the pairs, we find WD cooling ages to use as an additional constraint on the age-activity relation for our sample. We find that, on average, active early-type dMs tend to be younger and that active late-type dMs span a much broader age regime making them indistinguishable from the inactive late-type population. We also show that magnetic strength, as measured by H{alpha}, is comparable between paired and field M dwarfs until a spectral type of M6/M7 where M dwarf activity for stars with close companions becomes much stronger. In addition, we present 37 very close candidate pairs with fast-moving orbits that display radial velocity changes over hour timescales.« less
The Effects of Close Companions (and Rotation) on the Magnetic Activity of M Dwarfs
NASA Astrophysics Data System (ADS)
Morgan, Dylan P.; West, Andrew A.; Garcés, Ane; Catalán, Silvia; Dhital, Saurav; Fuchs, Miriam; Silvestri, Nicole M.
2012-10-01
We present a study of close white dwarf and M dwarf (WD+dM) binary systems and examine the effect that a close companion has on the magnetic field generation in M dwarfs. We use a base sample of 1602 white dwarf main-sequence binaries from Rebassa-Mansergas et al. to develop a set of color cuts in GALEX, SDSS, UKIDSS, and 2MASS color space. Then using the SDSS Data Release 8 spectroscopic database, we construct a sample of 1756 WD+dM high-quality pairs from our color cuts and previous catalogs. We separate the individual WD and dM from each spectrum using an iterative technique that compares the WD and dM components to best-fit templates. Using the absolute height above the Galactic plane as a proxy for age, and the Hα emission line as an indicator for magnetic activity, we investigate the age-activity relation for our sample for spectral types <= M7. Our results show that early-type M dwarfs (<=M4) in close binary systems are more likely to be active and have longer activity lifetimes compared to their field counterparts. However, at a spectral type of M5 (just past the onset of full convection in M dwarfs), the activity fraction and lifetimes of WD+dM binary systems become more comparable to that of the field M dwarfs. One of the implications of having a close binary companion is presumed to be increased stellar rotation through disk disruption, tidal effects, or angular momentum exchange. Thus, we interpret the similarity in activity behavior between late-type dMs in WD+dM pairs and late-type field dMs to be due to a decrease in sensitivity in close binary companions (or stellar rotation), which has implications for the nature of magnetic activity in fully convective stars. Using the WD components of the pairs, we find WD cooling ages to use as an additional constraint on the age-activity relation for our sample. We find that, on average, active early-type dMs tend to be younger and that active late-type dMs span a much broader age regime making them indistinguishable from the inactive late-type population. We also show that magnetic strength, as measured by Hα, is comparable between paired and field M dwarfs until a spectral type of M6/M7 where M dwarf activity for stars with close companions becomes much stronger. In addition, we present 37 very close candidate pairs with fast-moving orbits that display radial velocity changes over hour timescales.
In vitro stimulation with a strongly pulsed electromagnetic field on rat basophilic leukemia cells
NASA Astrophysics Data System (ADS)
Choi, J. W.; Shin, S. C.; Kim, S.; Chung, E. R.; Bang, J. H.; Cho, G. I.; Choi, S. D.; Park, Y. S.; Jang, T. S.; Yoo, Y. M.; Lee, S. S.; Hwang, D. G.
2010-05-01
In this study, the effects of pulsed electromagnetic field stimulation with a strong magnetic field on rat basophilic leukemia (RBL-2H3) cells were investigated to confirm the efficacy of the magnetic stimulator for biomedical applications. The maximum intensity of the magnetic field generated from the stimulation coil was 0.203 T, and the transition time was 126 μs. The oscillation time and frequency of the pulsed field were almost 0.1 ms and 8 kHz, respectively. The cell count as well as the mRNA expression and DNA sequence of the cytokine genes, such as the tumor necrosis factor-α (TNF-α) and interleukin-4 (IL-4), of the stimulated RBL-2H3 cells were analyzed with a hemocytometer and via reverse transcriptase polymerase chain reaction to determine the physiological response under a strong pulse field. After 12 h stimulation, cell death was observed at an increasing scale with the increase in the stimulation time. On the other hand, the cells that were stimulated for 10 min almost doubled as the interval time between the stimulations was extended.
Al3+ ions dependent structural and magnetic properties of Co-Ni nano-alloys.
Kadam, R H; Alone, Suresh T; Gaikwad, Anil S; Birajdar, A P; Shirsath, Sagar E
2014-06-01
Ferrite samples with a chemical formula Co0.5Ni0.5Al(x)Fe(2-x)O4 (where x = 0.0, 0.25, 0.5, 0.75 and 1.0) were synthesized by sol-gel auto-combustion method. The synthesized samples were annealed at 600 degrees C for 4 h. An analysis of X-ray diffraction (XRD) patterns reveals the formation of single phase cubic spinel structure. The lattice parameter decreased linearly with the increasing Al content x. Nano size of the powders were confirmed by the transmission electron micrographs (TEM). Particle size, bulk density decreased whereas specific surface area and porosity of the samples increased with the Al substitution. Cation distribution of constituent ions shows linear dependence of Al substitution. Based on the cation distribution obtained from XRD data, structural parameters such as lattice parameters, ionic radii of available sites and the oxygen parameter 'u' is calculated. Saturation magnetization (M(s)), magneton number (n(B)) and coercivity (H(c)) decreased with the Al substitution. Possible explanation for the observed structural and magnetic behavior with various Al content are discussed.
Yamout, Bassem I; Alroughani, Raed
2018-04-01
Multiple sclerosis (MS) is a chronic central nervous system inflammatory disease of autoimmune etiology, mediated by activated T cells with evolving evidence of a significant contribution from B cells and cells of the innate immune system. The disease is thought to be due to a complex interaction between different genetic and environmental factors. The prevalence of MS is rising all over the world, due on one hand to earlier diagnosis and prolonged survival, and on the other to a true increase in incidence of the disease. The diagnosis of MS remains clinical despite recent advances in diagnostics and relies on demonstrating dissemination in space and time while excluding alternative diagnoses. The Mc Donald diagnostic criteria, with their recent 2017 revision, are currently widely accepted in the MS community. Although no cure is yet available, many disease-modifying therapies (DMTs) have shown different levels of efficacy in preventing relapses, accumulation of lesions on magnetic resonance imaging (MRI), and disability progression. Current treatment strategies include gradual escalation based on clinical and radiological criteria that determine treatment response, or initial induction with high efficacy DMTs especially in patients with an early aggressive course. Thieme Medical Publishers 333 Seventh Avenue, New York, NY 10001, USA.
Ferrofluids based on Co-Fe-Si-B amorphous nanoparticles
NASA Astrophysics Data System (ADS)
Wang, Tianqi; Bian, Xiufang; Yang, Chuncheng; Zhao, Shuchun; Yu, Mengchun
2017-03-01
Magnetic Co-Fe-Si-B amorphous nanoparticles were successfully synthesized by chemical reduction method. ICP, XRD, DSC, and TEM were used to investigate the composition, structure and morphology of Co-Fe-Si-B samples. The results show that the Co-Fe-Si-B samples are amorphous, which consist of nearly spherical nanoparticles with an average particle size about 23 nm. VSM results manifest that the saturation magnetization (Ms) of Co-Fe-Si-B samples ranges from 46.37 to 62.89 emu/g. Two kinds of ferrofluids (FFs) were prepared by dispersing Co-Fe-Si-B amorphous nanoparticles and CoFe2O4 nanoparticles in kerosene and silicone oil, respectively. The magnetic properties, stability and viscosity of the FFs were investigated. The FFs with Co-Fe-Si-B samples have a higher Ms and lower coercivity (Hc) than FFs with CoFe2O4 sample. Under magnetic field, the silicone oil-based FFs exhibit high stability. The viscosity of FFs under different applied magnetic fields was measured by a rotational viscometer, indicating that FFs with Co-Fe-Si-B particles present relative strong response to an external magnetic field. The metal-boride amorphous alloy nanoparticles have potential applications in the preparation of magnetic fluids with good stability and good magnetoviscous properties.
Effect of post-annealing on the magnetic properties of sputtered Mn56Al44 thin films
NASA Astrophysics Data System (ADS)
Gupta, Nanhe Kumar; Husain, Sajid; Barwal, Vineet; Behera, Nilamani; Chaudhary, Sujeet
2018-05-01
Mn56Al44 (MnAl) thin films of constant thickness (˜30nm) were grown on naturally oxidized Si substrates using DC-magnetron sputtering. Effect of deposition parameters such as sputtering power, substrate temperature (Ts), and post-annealing temperature have been systematically invstigated. X-ray diffraction patterns revealed the presence of mixed phases, namely the τ- and β-MnAl. The highest saturation magnetization (MS) was found to be 65emu/cc using PPMS-VSM in film grown at Ts=500°C. The magnetic ordering was found to get significantly improved by performing post-annealing of these as-grwon at 400°C for 1 hr in the presence of out-of-plane magnetic field of ˜1500Oe in vacuum. In particular, at room temperature (RT), the MS got enhanced after magnetic annealing from 65emu/cc to 500 emu/cc in MnAl films grown at Ts=500°C. This sample exhibited a magneto-resistance of ˜1.5% at RT. The tuning of the structural and magnetic properties of MnAl binary alloy thin films as established here by varying the growth parameters is critical with regards to the prospective applications of MnAl, a metastable ferromagnetic system which possesses the highest perpendicular magnetic anisotropy at RT till date.
Magnetic and microwave absorbing properties of magnetite-thermoplastic natural rubber nanocomposites
NASA Astrophysics Data System (ADS)
Kong, Ing; Hj Ahmad, Sahrim; Hj Abdullah, Mustaffa; Hui, David; Nazlim Yusoff, Ahmad; Puryanti, Dwi
2010-11-01
Magnetic and microwave absorbing properties of thermoplastic natural rubber (TPNR) filled magnetite (Fe 3O 4) nanocomposites were investigated. The TPNR matrix was prepared from polypropylene (PP), natural rubber (NR) and liquid natural rubber (LNR) in the ratio of 70:20:10 with the LNR as the compatibilizer. TPNR-Fe 3O 4 nanocomposites with 4-12 wt% Fe 3O 4 as filler were prepared via a Thermo Haake internal mixer using a melt-blending method. XRD reveals the presence of cubic spinel structure of Fe 3O 4 with the lattice parameter of a=8.395 Å. TEM micrograph shows that the Fe 3O 4 nanoparticles are almost spherical with the size ranging 20-50 nm. The values of saturation magnetization ( MS), remanence ( MR), initial magnetic susceptibility ( χi) and initial permeability ( μi) increase, while the coercivity ( HC) decreases with increasing filler content for all compositions. For nanocomposites, the values of the real ( ɛr') and imaginary permittivity ( ɛr'') and imaginary permeability ( μr'') increase, while the value of real permeability ( μr') decreases as the filler content increases. The absorption or minimum reflection loss ( RL) continuously increases and the dip shifts to a lower frequency region with the increasing of both filler content in nanocomposites and the sample thickness. The RL is -25.51 dB at 12.65 GHz and the absorbing bandwidth in which the RL is less than -10 dB is 2.7 GHz when the filler content is 12 wt% at 9 mm sample thickness.
Haage, P; Adam, G; Misselwitz, B; Karaagac, S; Pfeffer, J G; Glowinski, A; Döhmen, S; Tacke, J; Günther, R W
2000-04-01
Magnetic resonance assessment of lung ventilation with aerosolized Gd-DTPA. Eleven experimental procedures were carried out in a domestic pig model. The intubated pigs were aerosolized for 30 minutes with an aqueous formulation of Gd-DTPA. The contrast agent aerosol was generated by a small particle aerosol generator. Imaging was performed on a 1.5 T MR imager using a T1-weighted turbo spin echo sequence with respiratory gating (TR 141 ms, TE 8.5 ms, 6 averages, slice thickness 10 mm). Pulmonary signal intensities before and after ventilation were measured in peripheral portions of both lungs. Immediately after ventilation with aerosolized Gd-DTPA, the signal intensity in both lungs increased significantly in all animals with values up to 237% above baseline (mean 139% +/- 48%), but with in some cases considerable regional intra- and interindividual intensity differences. Distinctive parenchymal enhancement was readily visualized in all eleven cases with good spatial resolution. The presented data indicate that Gd-DTPA in aerosolized form can be used to demonstrate pulmonary ventilation in large animals with lung volumes comparable to man. Further experimental trials are necessary to improve reproducibility and to define the scope of this method for depicting lung disease.
High temperature ferromagnetism in Ni doped ZnO nanoparticles: Milling time dependence
NASA Astrophysics Data System (ADS)
Pal, Bappaditya; Giri, P. K.; Sarkar, D.
2014-04-01
We report on the room temperature ferromagnetism (RT FM) in the Zn1-xNixO (x = 0, 0.03, and 0.05) nanoparticles (NPs) synthesized by a ball milling technique. X-ray diffraction analysis confirms the single crystalline ZnO wurtzite structure with presence of small intensity secondary phase related peak which disappear with increasing milling time for Ni doped samples. HRTEM lattice images show that the doped NPs are single crystalline with a dspacing of 2.44 Å. Energy-dispersive X-ray spectroscopy analysis confirms the presence of Ni ions in the ZnO matrix. Magnetic measurement (RT) exhibits the hysteresis loop with saturation magnetization (Ms) of 1.6-2.56 (emu/g) and coercive field (Hc) of 296-322 Oe. M-T measurement shows a Curie temperature of the order of 325°C for 3% Ni doped sample. Micro -Raman studies show doping/disorder induced additional modes at ˜510, 547, 572 cm-1 in addition to 437 cm-1 peak of pure ZnO. UV-Vis absorption spectra illustrate band gap shift due to doping. Alteration of Ms value with the variation of doping concentration and milling time has been studied and discussed.
NASA Astrophysics Data System (ADS)
Ali, Rajjab; Azhar Khan, Muhammad; Manzoor, Alina; Shahid, Muhammad; Farooq Warsi, Muhammad
2017-11-01
Ni0.5Sn0.5CoxMnxFe2-2xO4 ferrites with x = 0.0-0.8 have been prepared by the micro-emulsion method, using CTAB as a surfactant material. X-ray diffraction (XRD), Fourier transformed infrared spectroscopy (FTIR) and vibrational sample magnetometer (VSM) were used to investigate the effects of Co and Mn substitutions on cationic distribution, crystallite size, lattice constant, spectral, magnetic and dielectric properties. Lattice constant and crystallite size were found to increase from 7.4 to 9.25 Å and from 11.8 to 19.7 nm respectively with increasing substitution of Co and Mn ions. Saturation magnetization (MS) gradually increased from 20.5 to 47.6 emu/g with increase in the value of x. However, Coercivity increased from 152.7 to 462.4 Oe up to x = 0.4 and then it decreased thereafter. The dielectric constant, complex dielectric constant and tan loss (tanδ) were observed to decrease with increase in frequency, depicting the semiconductor behavior of the ferrites. Dc resistivity was observed to decrease considerably upon addition of Co and Mn content. The outcome for the tunable magnetic properties and achieved modification of the synthesized nanocrystallites may be chosen for tremendous applications; such as miniaturized memory devices that are based on the energy storage principles and capacitive components.
Stress-induced magnetization for epitaxial spinel ferrite films through interface engineering
NASA Astrophysics Data System (ADS)
Wakiya, Naoki; Shinozaki, Kazuo; Mizutani, Nobuyasu
2004-08-01
This study found "stress-induced magnetization" for epitaxial ferrite films with spinel structure. We grew (111)- and (001)-epitaxial Ni0.17Zn0.23Fe2.60O4(NZF) films on CeO2/Y0.15Zr0.85O1.93(YSZ )/Si(001) and oxide single-crystal substrates, respectively. There is a window of lattice mismatch (between 0 and 6.5%) to achieve bulk saturation magnetization (Ms). An NZF film grown on CeO2/YSZ //Si(001) showed tensile stress, but that stress was relaxed by introducing a ZnCo2O4(ZC ) buffer layer. NZF films grown on SrTiO3(ST )(001) and (La,Sr)(Al,Ta)O3(LSAT)(001) had compressive stress, which was enhanced by introducing a ZC buffer layer. In both cases, bulk Ms was achieved by introducing the ZC buffer layer. This similarity suggests that magnetization can be controlled by the stress.
First Signal on the Cryogenic Fourier-Transform Ion Cyclotron Resonance Mass Spectrometer
Lin, Cheng; Mathur, Raman; Aizikov, Kostantin; O'Connor, Peter B.
2009-01-01
The construction and achievement of the first signal on a cryogenic Fourier-transform ion cyclotron resonance mass spectrometer (FT-ICR-MS) are reported here, demonstrating proof-of-concept of this new instrument design. Building the FTICR cell into the cold bore of a superconducting magnet provided advantages over conventional warm bore design. At 4.2 K, the vacuum system cryopumps itself, thus removing the requirement for a large bore to achieve the desired pumping speed for maintaining base pressure. Furthermore, because the bore diameter has been reduced, the amount of magnet wire needed to achieve high field and homogeneity was also reduced, greatly decreasing the cost/Tesla of the magnet. The current instrument implements an actively shielded 14-Tesla magnet of vertical design with an external matrix assisted laser desorption/ionization (MALDI) source. The first signal was obtained by detecting the laser desorbed/ionized (LDI) C60+• ions, with the magnet at 7 Tesla, unshimmed, and the preamplifier mounted outside of the vacuum chamber at room temperature. A subsequent experiment done with the magnet at 14 Tesla and properly shimmed produced a C60 spectrum showing ∼350,000 resolving power at m/z ∼720. Increased magnetic field strength improves many FTMS performance parameters simultaneously, particularly mass resolving power and accuracy. PMID:17931882
Magnetic properties of TOAB-capped CuO nanoparticles.
NASA Astrophysics Data System (ADS)
Seehra, M.; Punnoose, A.; Mahamuni, S.
2002-03-01
Synthesis of CuO nanoparticles (NP) capped with TOAB (tetraoctylammonium bromide) and their structural properties were reported recently [1]. Here we report on the magnetic properties of the TOAB-capped CuO-NP of size 4, 6 and 10 nm and compare these properties with those of uncapped CuO-NP in the size range of 6.6-37 nm described in the above abstract [2] and in a recent publication [3]. Temperature (5 K 350 K) and magnetic field (up to 55 kOe) variations of magnetization M, coercivity H_c, exchange bias He (field-cooled in 55 kOe) and the Neel temperature TN (where He goes to zero) were measured. The TOAB-capped NP have higher magnitudes of Ms (the weak ferromagnetic component of M) and lower He values, confirming the 1/Ms variation of He observed in uncapped CuO-NP for size < 16 nm. The reasons for the larger Ms in the capped vs. uncapped CuO-NP are now under investigation. TN decreases with the decrease in the particle size, as also observed for the uncapped CuO-NP. Supported in part by U.S. DOE (contract DE-FC26-99FT40540). [1]. K. Borgohain et al, Phys. Rev. B61, 11093 (2000). [2]. A. Punnoose and M. S. Seehra, preceding abstract. [3]. Punnoose, Magnone, Seehra & Bonevich, Phys. Rev. B64, 174420 (2001).
Kallaur, Ana Paula; Oliveira, Sayonara Rangel; Simão, Andréa Name Colado; Alfieri, Daniela Frizon; Flauzino, Tamires; Lopes, Josiane; de Carvalho Jennings Pereira, Wildea Lice; de Meleck Proença, Caio; Borelli, Sueli Donizete; Kaimen-Maciel, Damacio Ramón; Maes, Michael; Reiche, Edna Maria Vissoci
2017-05-01
Inflammation is the driving force for brain injury in patients with multiple sclerosis (MS). The objective of the present study is to delineate the serum cytokine profile in patients with progressive MS in a Southern Brazilian population compared with healthy controls and patients with relapsing-remitting MS (RRMS) and its associations with disease progression and disability. We included 32 patients with progressive MS, 126 with RRMS, and 40 healthy controls. The patients were evaluated using the Expanded Disability Status Scale (EDSS) and magnetic resonance imaging (MRI) with gadolinium. Serum interleukin (IL)-1β, IL-6, IL-12, tumor necrosis factor (TNF)-α, interferon (IFN)-γ, IL-10, IL-4, and IL-17 levels were assessed using an enzyme-linked immunosorbent assay. IL-1β, IL-6, TNF-α, IFN-γ, IL-17, IL-4, and IL-10 levels were higher in progressive MS than in controls. Increased IL-1β and IFN-γ and decreased IL-12 and IL-4 levels were found in progressive MS compared with RRMS. Patients with progressive MS with disease progression presented higher TNF-α, IFN-γ, and IL-10 levels than those without disease progression. Patients with progressive MS with disease progression showed a higher frequency of positive gadolinium-enhanced lesions in MRI; higher TNF-α, IFN-γ, and IL-17 levels; and decreased IL-12 levels compared with RRMS patients with progression. There was a significant inverse correlation between IL-10 levels and EDSS score in patients with progressive MS. The results underscore the complex cytokine network imbalance exhibited by progressive MS patients and show the important involvement of TNF-α, IFN-γ, and IL-17 in the pathophysiology and progression of the disease. Moreover, serum IL-10 levels were inversely associated with disability in patients with progressive MS.
28 CFR 51.20 - Form of submissions.
Code of Federal Regulations, 2010 CFR
2010-07-01
... megabyte MS-DOS formatted diskettes; 5 1/4″ 1.2 megabyte MS-DOS formatted floppy disks; nine-track tape... provided in hard copy. (c) All magnetic media shall be clearly labeled with the following information: (1... a disk operating system (DOS) file, it shall be formatted in a standard American Standard Code for...
Imaging outcome measures for progressive multiple sclerosis trials
Moccia, Marcello; de Stefano, Nicola; Barkhof, Frederik
2017-01-01
Imaging markers that are reliable, reproducible and sensitive to neurodegenerative changes in progressive multiple sclerosis (MS) can enhance the development of new medications with a neuroprotective mode-of-action. Accordingly, in recent years, a considerable number of imaging biomarkers have been included in phase 2 and 3 clinical trials in primary and secondary progressive MS. Brain lesion count and volume are markers of inflammation and demyelination and are important outcomes even in progressive MS trials. Brain and, more recently, spinal cord atrophy are gaining relevance, considering their strong association with disability accrual; ongoing improvements in analysis methods will enhance their applicability in clinical trials, especially for cord atrophy. Advanced magnetic resonance imaging (MRI) techniques (e.g. magnetization transfer ratio (MTR), diffusion tensor imaging (DTI), spectroscopy) have been included in few trials so far and hold promise for the future, as they can reflect specific pathological changes targeted by neuroprotective treatments. Position emission tomography (PET) and optical coherence tomography have yet to be included. Applications, limitations and future perspectives of these techniques in clinical trials in progressive MS are discussed, with emphasis on measurement sensitivity, reliability and sample size calculation. PMID:29041865
NASA Astrophysics Data System (ADS)
Xue-Feng, Zhang; Jian-Ting, Lan; Zhu-Bai, Li; Yan-Li, Liu; Le-Le, Zhang; Yong-Feng, Li; Qian, Zhao
2016-05-01
Resource-saving (PrNdCe)2Fe14B sintered magnets with nominal composition (PrNd)15-x Ce x Fe77B8 (x = 0-10) were prepared using a dual alloy method by mixing (PrNd)5Ce10Fe77B8 with (PrNd)15Fe77B8 powders. For Ce atomic percent of 1% and 2%, coercivity decreases dramatically. With further increase of Ce atomic percent, the coercivity increases, peaks at 6.38 kOe in (PrNd)11Ce4Fe77B8, and then declines gradually. The abnormal dependence of coercivity is likely related to the inhomogeneity of rare earth chemical composition in the intergranular phase, where PrNd concentration is strongly dependent on the additive amount of (PrNd)5Ce10Fe77B8 powders. In addition, for Ce atomic percent of 8%, 7%, and 6% the coercivity is higher than that of magnets prepared by the conventional method, which shows the advantage of the dual alloy method in preparing high abundant rare earth magnets. Project supported by the National Natural Science Foundation of China (Grant Nos. 51461033, 51571126, 51541105, and 11547032), the Natural Science Foundation of Inner Mongolia, China (Grant No. 2013MS0110), and the Inner Mongolia University of Science and Technology Innovation Fund, China.
Chiu, Pui-Wai; Mak, Henry Ka-Fung; Yau, Kelvin Kai-Wing; Chan, Queenie; Chang, Raymond Chuen-Chung; Chu, Leung-Wing
2014-02-01
Magnetic resonance spectroscopy (MRS) can explore aging at a molecular level. In this study, we investigated the relationships between regional concentrations of metabolites (such as choline, creatine, myo-inositol, and N-acetyl-aspartate) and normal aging in 30 cognitively normal subjects (15 women and 15 men, age range 22-82, mean = 49.9 ± 18.3 years) using quantitative proton magnetic resonance spectroscopy. All MR scans were performed using a 3 T scanner. Point resolved spectroscopy was used as the volume selection method for the region-of-interest and the excitation method for water suppression. Single voxel spectroscopy with short echo time of 39 ms and repetition time of 2,000 ms was employed. Single voxels were placed in the limbic regions, i.e., anterior cingulate cortex (ACC), posterior cingulate cortex (PCC), and left and right hippocampi. Cerebrospinal fluid normalization and T1 and T2 correction factors were implemented in the calculation of absolute metabolite concentrations. A standardized T1W 3D volumetric fast field echo and axial T2-weighted fast spin-echo images were also acquired. Our results showed significant positive correlation of choline (r = 0.545, p = 0.002), creatine (r = 0.571, p = 0.001), and N-acetyl-aspartate (r = 0.674, p < 0.001) in the ACC; choline (r = 0.614, p < 0.001), creatine (r = 0.670, p < 0.001), and N-acetyl-aspartate (r = 0.528, p = 0.003) in the PCC; and NAA (r = 0.409, p = 0.025) in the left hippocampus, with age. No significant gender effect on metabolite concentrations was found. In aging, increases in choline and creatine might suggest glial proliferation, and an increase in N-acetyl-aspartate might indicate neuronal hypertrophy. Such findings highlight the metabolic changes of ACC and PCC with age, which could be compensatory to an increased energy demand coupled with a lower cerebral blood flow.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Breitkreutz, D.; Fallone, B. G.; Yahya, A.
2014-06-15
Purpose: To improve proton magnetic resonance spectroscopy (MRS) transverse relaxation (T{sub 2}) determination and quantification of lipid methylene chain (1.3 ppm) protons by rewinding their J-coupling evolution. Methods: MRS experiments were performed on four lipid phantoms, namely, almond, corn, sunflower and oleic acid, using a 3 T Philips MRI scanner with a transmit/receive birdcage head coil. Two PRESS (Point RESolved Spectroscopy) pulse sequences were used. The first PRESS sequence employed standard bandwidth (BW) (∼550 Hz) RF (radiofrequency) refocussing pulses, while the second used refocussing pulses of narrow BW (∼50 Hz) designed to rewind J-coupling evolution of the methylene protons inmore » the voxel of interest. Signal was acquired with each sequence from a 5×5×5 mm{sup 3} voxel, with a repetition time (TR) of 3000 ms, and with echo times (TE) of 100 to 200 ms in steps of 20 ms. 2048 sample points were measured with a 2000 Hz sampling bandwidth. Additionally, 30 mm outer volume suppression slabs were used to suppress signal outside the voxel of interest. The frequency of the RF pulses was set to that of the methylene resonance. Methylene peak areas were calculated and fitted in MATLAB to a monexponentially decaying function of the form M{sub 0}exp(-TE/T{sub 2}), where M{sub 0} is the extrapolated area when TE = 0 ms and yields a measure of concentration. Results: The determined values of M{sub 0} and T{sub 2} increased for all fatty acids when using the PRESS sequence with narrow BW refocussing pulses. M{sub 0} and T{sub 2} values increased by an average amount (over all the phantoms) of 31% and 14%, respectively. Conclusion: This investigation has demonstrated that J-coupling interactions of lipid methylene protons causes non-negligible signal losses which, if not accounted for, Result in underestimations of their levels and T{sub 2} values when performing MRS measurements. Funded by the Natural Sciences and Engineering Research Council of Canada and the Canadian Breast Cancer Foundation - Prairies.NWT.« less
Martins-Bach, Aurea B; Malheiros, Jackeline; Matot, Béatrice; Martins, Poliana C M; Almeida, Camila F; Caldeira, Waldir; Ribeiro, Alberto F; Loureiro de Sousa, Paulo; Azzabou, Noura; Tannús, Alberto; Carlier, Pierre G; Vainzof, Mariz
2015-01-01
Quantitative nuclear magnetic resonance imaging (MRI) has been considered a promising non-invasive tool for monitoring therapeutic essays in small size mouse models of muscular dystrophies. Here, we combined MRI (anatomical images and transverse relaxation time constant-T2-measurements) to texture analyses in the study of four mouse strains covering a wide range of dystrophic phenotypes. Two still unexplored mouse models of muscular dystrophies were analyzed: The severely affected Largemyd mouse and the recently generated and worst double mutant mdx/Largemyd mouse, as compared to the mildly affected mdx and normal mice. The results were compared to histopathological findings. MRI showed increased intermuscular fat and higher muscle T2 in the three dystrophic mouse models when compared to the wild-type mice (T2: mdx/Largemyd: 37.6±2.8 ms; mdx: 35.2±4.5 ms; Largemyd: 36.6±4.0 ms; wild-type: 29.1±1.8 ms, p<0.05), in addition to higher muscle T2 in the mdx/Largemyd mice when compared to mdx (p<0.05). The areas with increased muscle T2 in the MRI correlated spatially with the identified histopathological alterations such as necrosis, inflammation, degeneration and regeneration foci. Nevertheless, muscle T2 values were not correlated with the severity of the phenotype in the 3 dystrophic mouse strains, since the severely affected Largemyd showed similar values than both the mild mdx and worst mdx/Largemyd lineages. On the other hand, all studied mouse strains could be unambiguously identified with texture analysis, which reflected the observed differences in the distribution of signals in muscle MRI. Thus, combined T2 intensity maps and texture analysis is a powerful approach for the characterization and differentiation of dystrophic muscles with diverse genotypes and phenotypes. These new findings provide important noninvasive tools in the evaluation of the efficacy of new therapies, and most importantly, can be directly applied in human translational research.
Martins-Bach, Aurea B.; Malheiros, Jackeline; Matot, Béatrice; Martins, Poliana C. M.; Almeida, Camila F.; Caldeira, Waldir; Ribeiro, Alberto F.; Loureiro de Sousa, Paulo; Azzabou, Noura; Tannús, Alberto; Carlier, Pierre G.; Vainzof, Mariz
2015-01-01
Quantitative nuclear magnetic resonance imaging (MRI) has been considered a promising non-invasive tool for monitoring therapeutic essays in small size mouse models of muscular dystrophies. Here, we combined MRI (anatomical images and transverse relaxation time constant—T2—measurements) to texture analyses in the study of four mouse strains covering a wide range of dystrophic phenotypes. Two still unexplored mouse models of muscular dystrophies were analyzed: The severely affected Largemyd mouse and the recently generated and worst double mutant mdx/Largemyd mouse, as compared to the mildly affected mdx and normal mice. The results were compared to histopathological findings. MRI showed increased intermuscular fat and higher muscle T2 in the three dystrophic mouse models when compared to the wild-type mice (T2: mdx/Largemyd: 37.6±2.8 ms; mdx: 35.2±4.5 ms; Largemyd: 36.6±4.0 ms; wild-type: 29.1±1.8 ms, p<0.05), in addition to higher muscle T2 in the mdx/Largemyd mice when compared to mdx (p<0.05). The areas with increased muscle T2 in the MRI correlated spatially with the identified histopathological alterations such as necrosis, inflammation, degeneration and regeneration foci. Nevertheless, muscle T2 values were not correlated with the severity of the phenotype in the 3 dystrophic mouse strains, since the severely affected Largemyd showed similar values than both the mild mdx and worst mdx/Largemyd lineages. On the other hand, all studied mouse strains could be unambiguously identified with texture analysis, which reflected the observed differences in the distribution of signals in muscle MRI. Thus, combined T2 intensity maps and texture analysis is a powerful approach for the characterization and differentiation of dystrophic muscles with diverse genotypes and phenotypes. These new findings provide important noninvasive tools in the evaluation of the efficacy of new therapies, and most importantly, can be directly applied in human translational research. PMID:25710816
NASA Astrophysics Data System (ADS)
Antarnusa, G.; Elda Swastika, P.; Suharyadi, E.
2018-04-01
A Wheatstone bridge-giant magnetoresistance (GMR) sensor was successfully developed for a potential biomaterial detection. In order to achieve this, a giant magnetoresistive [Co(1.5nm/Cu(1.0nm)]20 multilayer structures have been fabricated by DC magnetron sputtering method, showing a magnetoresistance (MR) of 2.7%. The X-Ray diffraction (XRD) patterns showed that Co/Cu film multilayer has a high degree of crystallinity with a single peak corresponding to face-centered cubic (111) structure at 2θ = 44.1°. Co/Cu multilayers exhibit a soft magnetic behavior with the saturation magnetization (Ms) of 1489 emu/cc and the coercivity (Hc) of 11.2 Oe. The magnetite Fe3O4 nanoparticles used as a bimolecular labels (nanotags) were synthesized via co-precipitation method, exhibiting a soft magnetic behavior with Ms of 77.16 emu/g and Hc of 49 Oe. XRD patterns and transmission electron microscopy (TEM) images showed that Fe3O4 was well crystallized and it grew in their inverse spinel structure with an average size of around 10 nm. The GMR sensor design was used to detect a biomolecules of streptavidin magnetic particles with concentration 10, 20, 30, and 40 μl/ml and α-amylase enzyme with consentration 10, 20, 30, and 40 μl/ml captured using polyethylene glycol (PEG)/Fe3O4 nanoparticles. Various applied magnetic fields of 0-650 Gauss have been performed using electromagnetic with the various currents of 0-5 A. Here, the final value of the output voltage signals for the streptavidin magnetic particles concentration is 1.2 mV (10 μl/ml). The output voltage changes with the increase of concentration. It was reported that the output voltage signal of the Wheatstone bridge exhibits log-linear function in real time measurement of the concentration of streptavidin magnetic particles and α-amylase enzyme respectively, making the sensor suitable for use as a biomolecule concentration detector. Thus, the combination of Co/Cu multilayer, Wheatstone bridge, magnetite and PEG polymer has potential application to be used in bio-detection applications where ultra-small bio-labels are needed.
Luo, Yan-Bo; Yu, Qiong-Wei; Yuan, Bi-Feng; Feng, Yu-Qi
2012-02-15
In this work, magnetic carbon nanotubes (CNTs) were prepared by mixing the magnetic particles and multi-walled carbon nanotubes dispersed solutions. Due to their excellent adsorption capability towards hydrophobic compounds, the magnetic CNTs were used as adsorbent of magnetic solid-phase extraction (MSPE) to extract phthalate acid esters (PAEs), which are widely used in many consumable products with potential carcinogenic properties. By coupling MSPE with gas chromatography/mass spectrometry (GC/MS), a rapid, sensitive and cost-effective method for the analysis of PAEs was established. Our results showed that the limits of detection (LODs) of 16 PAEs ranged from 4.9 to 38 ng L(-1), which are much lower compared to the previously reported methods. And good linearities of the detection method were obtained with correlation coefficients (R(2)) between 0.9821 and 0.9993. In addition, a satisfying reproducibility was achieved by evaluating the intra- and inter-day precisions with relative standard deviations (RSDs) less than 11.7% and 14.6%, respectively. Finally, the established MSPE-GC/MS method was successfully applied to the determination of PAEs from bottled beverages, tap water and perfume samples. The recoveries of the 16 PAEs from the real samples ranged from 64.6% to 125.6% with the RSDs less than 16.5%. Taken together, the MSPE-GC/MS method developed in current study provides a new option for the detection of PAEs from real samples with complex matrices. Copyright © 2012 Elsevier B.V. All rights reserved.
Tiffany Win, Theingi; Ambale Venkatesh, Bharath; Volpe, Gustavo J; Mewton, Nathan; Rizzi, Patricia; Sharma, Ravi K; Strauss, David G; Lima, Joao A; Tereshchenko, Larisa G
2015-01-01
Abnormal P-terminal force in lead V1 (PTFV1) is associated with an increased risk of heart failure, stroke, atrial fibrillation, and death. Our goal was to explore associations of left ventricular (LV) diffuse fibrosis with left atrial (LA) function and electrocardiographic (ECG) measures of LA electrical activity. Patients without atrial fibrillation (n = 91; mean age 59.5 years; 61.5% men; 65.9% white) with structural heart disease (spatial QRS-T angle ≥105° and/or Selvester QRS score ≥5 on ECG) but LV ejection fraction >35% underwent clinical evaluation, cardiac magnetic resonance, and resting ECG. LA function indices were obtained by multimodality tissue tracking using 2- and 4-chamber long-axis images. T1 mapping and late gadolinium enhancement were used to assess diffuse LV fibrosis and presence of scar. P-prime in V1 amplitude (PPaV1) and duration (PPdV1), averaged P-wave-duration, PR interval, and P-wave axis were automatically measured using 12 SLTM algorithm. PTFV1 was calculated as a product of PPaV1 and PPdV1. In linear regression after adjustment for demographic characteristics, body mass index, maximum LA volume index, presence of scar, and LV mass index, each decile increase in LV interstitial fibrosis was associated with 0.76 mV*ms increase in negative abnormal PTFV1 (95% confidence interval [CI] -1.42 to -0.09; P = .025), 15.3 ms prolongation of PPdV1 (95% CI 6.9 to 23.8; P = .001) and 5.4 ms prolongation of averaged P-duration (95% CI 0.9-10.0; P = .020). LV fibrosis did not affect LA function. PPaV1 and PTFV1 were associated with an increase in LA volumes and decrease in LA emptying fraction and LA reservoir function. LV interstitial fibrosis is associated with abnormal PTFV1, prolonged PPdV1, and P-duration, but does not affect LA function. Copyright © 2015 Heart Rhythm Society. All rights reserved.
2015-10-01
with fMRI , and CEST acquisitions. Analysis hurdles were noted in the qMT, which we discuss here. Recruitment continues in the MS cohort (all healthy...Saturation Transfer (CEST) • Magnetization Transfer (MT) • Brain • Cortical Gray Matter (cGM) • Multiple Sclerosis (MS) • Functional MRI ( fMRI ) • Pool Size...MPRAGE Anatomical – 2:12 • fMRI Resting State – 8:34 • fMRI N-Back task – 8:30 • fMRI Trailmaking task – 4:14 The current scan time for all scans is
Yu, Xiaoxiao; Chen, Beibei; He, Man; Wang, Han; Hu, Bin
2018-03-01
The quantification of trace Cd and Se in cells incubated with CdSe quantum dots (QDs) is critical to investigate the cytotoxicity of CdSe QDs. In this work, a miniaturized platform, namely chip-based magnetic solid phase microextraction (MSPME) packing with sulfhydryl group functionalized magnetic nanoparticles, was fabricated and combined with inductively coupled plasma mass spectrometry (ICP-MS) for the determination of trace Cd and Se in cells. Under the optimized conditions, the limits of detection (LOD) of the developed chip-based MSPME-ICP-MS system are 2.2 and 21ngL -1 for Cd and Se, respectively. The proposed method is applied successfully to the analysis of total and released small molecular fraction of Cd and Se in Human hepatocellular carcinoma cells (HepG2 cells) incubated with CdSe QDs, and the recoveries for the spiked samples are in the range of 86.0-109%. This method shows great promise to analyze cell samples and the obtained results are instructive to explore the cytotoxicity mechanism of CdSe QDs in cells. Copyright © 2017 Elsevier B.V. All rights reserved.
NASA Astrophysics Data System (ADS)
Stanbro, M.; Briggs, M. S.; Cramer, E.; Dwyer, J. R.; Roberts, O.
2017-12-01
Terrestrial Gamma-ray Flashes (TGFs) are sub-ms, intense flashes of gamma-rays. They are due to the acceleration of electrons with relativistic energies in thunderstorms that emit gamma-rays via bremsstrahlung. When these photons reach the upper atmosphere, they can produce secondary electrons and positrons that escape the atmosphere and propagate along the Earth's magnetic field line. Space instruments can detect these charged particles, known as Terrestrial Electron Beams (TEBs), after traveling thousands of kilometers from the thunderstorm. We present an event that was observed by the Fermi Gamma-ray Burst Monitor (GBM) as both a TGF and a TEB. To our knowledge this is the first such event that has ever been observed. We interpret the first pulse as a TGF with a duration of 0.2 ms. After 0.5 ms a second pulse is seen with a duration of 2 ms that we interpret as a TEB. Confirming this interpretation, a third pulse is seen 90 ms later, which is understood as a TEB magnetic mirror pulse. The World Wide Lightning Location Network (WWLLN) and the Earth Networks Total Lightning Network (ENTLN) detected a sferic, under the spacecraft footprint and within the southern magnetic footprint that is simultaneous with the first pulse. Along with the sferic, this unique observation allows us for the first time to test TGF and TEB models for the same event. We present Monte Carlo simulations of the first two pulses, including pitch angles for electrons and positrons, to see if the models can consistently describe the TGF/TEB spectra and time profiles originating from the same source.
Piovesana, Susy; Capriotti, Anna Laura; Cavaliere, Chiara; La Barbera, Giorgia; Samperi, Roberto; Zenezini Chiozzi, Riccardo; Laganà, Aldo
2017-07-01
Magnetic solid-phase extraction is one of the most promising new extraction methods for liquid samples before ultra-high-performance liquid chromatography-tandem mass spectrometry (UHPLC-MS/MS) analysis. Several types of materials, including carbonaceous ones, have been prepared for this purpose. In this paper, for the first time, the preparation, characterization, and sorption capability of Fe 3 O 4 -graphitized carbon black (mGCB) composite toward some compounds of environmental interest were investigated. The synthesized mGCB consisted of micrometric GCB particles with 55 m 2 g -1 surface area bearing some carbonyl and hydroxyl functionalities and the surface partially decorated by Fe 3 O 4 microparticles. The prepared mGCB was firstly tested as an adsorbent for the extraction from surface water of 50 pollutants, including estrogens, perfluoroalkyl compounds, UV filters, and quinolones. The material showed good affinity to many of the tested compounds, except carboxylates and glucoronates; however, some compounds were difficult to desorb. Ten UV filters belonging to the chemical classes of benzophenones and p-aminobenzoates were selected, and parameters were optimized for the extraction of these compounds from surface water before UHPLC-MS/MS determination. Then, the method was validated in terms of linearity, trueness, intra-laboratory precision, and detection and quantification limits. In summary, the method performance (trueness, expressed as analytical recovery, 85-114%; RSD 5-15%) appears suitable for the determination of the selected compounds at the level of 10-100 ng L -1 , with detection limits in the range of 1-5 ng L -1 . Finally, the new method was compared with a published one, based on conventional solid-phase extraction with GCB, showing similar performance in real sample analysis. Graphical Abstract Workflow of the analytical method based on magnetic solid-phase extraction followed by LC-MS/MS determination.
Correlation of Mechanical Properties in Bulk Metallic Glasses with 27Al NMR Characteristics
2011-12-01
recycle delay of 300 ms. Magnetization measurements were conducted at room temperature using a Quantum Design SQUID magne- tometer. The magnetization of...Gangopadhyay A K, et al. First X-ray scattering studies on electrostatically levitated metallic liquids: Demonstrated influence of local icosahedral
Guan, Yajing; Wang, Jianchen; Tian, Yixin; Hu, Weimin; Zhu, Liwei; Zhu, Shuijin; Hu, Jin
2013-01-01
Seed security is of prime importance for agriculture. To protect true seeds from being faked, more secure dual anti-counterfeiting technologies for tobacco (Nicotiana tabacum L.) pelleted seed were developed in this paper. Fluorescein (FR), rhodamine B (RB), and magnetic powder (MP) were used as anti-counterfeiting labels. According to their different properties and the special seed pelleting process, four dual-labeling treatments were conducted for two tobacco varieties, MS Yunyan85 (MSYY85) and Honghua Dajinyuan (HHDJY). Then the seed germination and seedling growth status were investigated, and the fluorescence in cracked pellets and developing seedlings was observed under different excitation lights. The results showed that FR, RB, and MP had no negative effects on the germination, seedling growth, and MDA content of the pelleted seeds, and even some treatments significantly enhanced seedling dry weight, vigor index, and shoot height in MS YY85, and increased SOD activity and chlorophyll content in HHDJY as compared to the control. In addition, the cotyledon tip of seedlings treated with FR and MP together represented bright green fluorescence under illumination of blue light (478 nm). And the seedling cotyledon vein treated with RB and MP together showed red fluorescence under green light (546 nm). All seeds pelleted with magnetic powder of proper concentration could be attracted by a magnet. Thus, it indicated that those new dual-labeling methods that fluorescent compound and magnetic powder simultaneously applied in the same seed pellets definitely improved anti-counterfeiting technology and enhanced the seed security. This technology will ensure that high quality seed will be used in the crop production. PMID:23468953
Development of Immunocapture-LC/MS Assay for Simultaneous ADA Isotyping and Semiquantitation
2016-01-01
Therapeutic proteins and peptides have potential to elicit immune responses resulting in anti-drug antibodies that can pose problems for both patient safety and product efficacy. During drug development immunogenicity is usually examined by risk-based approach along with specific strategies for developing “fit-for-purpose” bioanalytical approaches. Enzyme-linked immunosorbent assays and electrochemiluminescence immunoassays are the most widely used platform for ADA detection due to their high sensitivity and throughput. During the past decade, LC/MS has emerged as a promising technology for quantitation of biotherapeutics and protein biomarkers in biological matrices, mainly owing to its high specificity, selectivity, multiplexing, and wide dynamic range. In fully taking these advantages, we describe here an immunocapture-LC/MS methodology for simultaneous isotyping and semiquantitation of ADA in human plasma. Briefly, ADA and/or drug-ADA complex is captured by biotinylated drug or anti-drug Ab, immobilized on streptavidin magnetic beads, and separated from human plasma by a magnet. ADA is then released from the beads and subjected to trypsin digestion followed by LC/MS detection of specific universal peptides for each ADA isotype. The LC/MS data are analyzed using cut-point and calibration curve. The proof-of-concept of this methodology is demonstrated by detecting preexisting ADA in human plasma. PMID:27034966
Development of Immunocapture-LC/MS Assay for Simultaneous ADA Isotyping and Semiquantitation.
Chen, Lin-Zhi; Roos, David; Philip, Elsy
2016-01-01
Therapeutic proteins and peptides have potential to elicit immune responses resulting in anti-drug antibodies that can pose problems for both patient safety and product efficacy. During drug development immunogenicity is usually examined by risk-based approach along with specific strategies for developing "fit-for-purpose" bioanalytical approaches. Enzyme-linked immunosorbent assays and electrochemiluminescence immunoassays are the most widely used platform for ADA detection due to their high sensitivity and throughput. During the past decade, LC/MS has emerged as a promising technology for quantitation of biotherapeutics and protein biomarkers in biological matrices, mainly owing to its high specificity, selectivity, multiplexing, and wide dynamic range. In fully taking these advantages, we describe here an immunocapture-LC/MS methodology for simultaneous isotyping and semiquantitation of ADA in human plasma. Briefly, ADA and/or drug-ADA complex is captured by biotinylated drug or anti-drug Ab, immobilized on streptavidin magnetic beads, and separated from human plasma by a magnet. ADA is then released from the beads and subjected to trypsin digestion followed by LC/MS detection of specific universal peptides for each ADA isotype. The LC/MS data are analyzed using cut-point and calibration curve. The proof-of-concept of this methodology is demonstrated by detecting preexisting ADA in human plasma.
Grimley, D.A.; Follmer, L.R.; McKay, E.D.
1998-01-01
Magnetic susceptibility (MS) patterns have proven useful for regional stratigraphic correlations of zones within thick, oxidized Peoria and Roxana Silts along the Illinois and Central Mississippi River valleys for more than 350 km. Variations in MS of C horizon loess are controlled by silt-sized magnetite content and are interpreted to reflect changes in sediment provenance due to fluctuations of the Superior and Lake Michigan glacier lobes and the diversion of the Mississippi River to its present course. Grain size distributions and scanning electron microscopic observations indicate that stratigraphic changes in MS are not significantly influenced by eolian sorting or diagenetic dissolution, respectively. Three compositional zones (lower, middle, and upper) are delineated within Peoria Silt which usually can be traced in the field by MS, the occurrence of clay beds, interstadial soils, and/or subtle color changes. These zones can be correlated with, but are generally of more practical use than, previously studied dolomite zones (McKay, 1977) or clay mineral zones (Frye et al., 1968). However, mineralogical analyses can help to substantiate zone boundaries when in question. MS and compositional zones may indirectly record a climatic signal, primarily through the effect that global cooling has had on ice lobe fluctuations in the Upper Mississippi drainage basin. ?? 1998 University of Washington.
Kerr, Deborah L.; Nitschke, Jack B.
2013-01-01
Abstract Granger causality analysis of functional magnetic resonance imaging (fMRI) blood-oxygen-level-dependent signal data allows one to infer the direction and magnitude of influence that brain regions exert on one another. We employed a method for upsampling the time resolution of fMRI data that does not require additional interpolation beyond the interpolation that is regularly used for slice-timing correction. The mathematics for this new method are provided, and simulations demonstrate its viability. Using fMRI, 17 snake phobics and 19 healthy controls viewed snake, disgust, and neutral fish video clips preceded by anticipatory cues. Multivariate Granger causality models at the native 2-sec resolution and at the upsampled 400-ms resolution assessed directional associations of fMRI data among 13 anatomical regions of interest identified in prior research on anxiety and emotion. Superior sensitivity was observed for the 400-ms model, both for connectivity within each group and for group differences in connectivity. Context-dependent analyses for the 400-ms multivariate Granger causality model revealed the specific trial types showing group differences in connectivity. This is the first demonstration of effective connectivity of fMRI data using a method for achieving 400-ms resolution without sacrificing accuracy available at 2-sec resolution. PMID:23134194
Jets from Merging Neutron Stars
NASA Astrophysics Data System (ADS)
Kohler, Susanna
2016-06-01
With the recent discovery of gravitational waves from the merger of two black holes, its especially important to understand the electromagnetic signals resulting from mergers of compact objects. New simulations successfully follow a merger of two neutron stars that produces a short burst of energy via a jet consistent with short gamma-ray burst (sGRB) detections.Still from the authors simulation showing the two neutron stars, and their magnetic fields, before merger. [Adapted from Ruiz et al. 2016]Challenging SystemWe have long suspected that sGRBs are produced by the mergers of compact objects, but this model has been difficult to prove. One major hitch is that modeling the process of merger and sGRB launch is very difficult, due to the fact that these extreme systems involve magnetic fields, fluids and full general relativity.Traditionally, simulations are only able to track such mergers over short periods of time. But in a recent study, Milton Ruiz (University of Illinois at Urbana-Champaign and Industrial University of Santander, Colombia) and coauthors Ryan Lang, Vasileios Paschalidis and Stuart Shapiro have modeled a binary neutron star system all the way through the process of inspiral, merger, and the launch of a jet.A Merger TimelineHow does this happen? Lets walk through one of the teams simulations, in which dipole magnetic field lines thread through the interior of each neutron star and extend beyond its surface(like magnetic fields found in pulsars). In this example, the two neutron stars each have a mass of 1.625 solar masses.Simulation start (0 ms)Loss of energy via gravitational waves cause the neutron stars to inspiral.Merger (3.5 ms)The neutron stars are stretched by tidal effects and make contact. Their merger produces a hypermassive neutron star that is supported against collapse by its differential (nonuniform) rotation.Delayed collapse into a black hole (21.5 ms)Once the differential rotation is redistributed by magnetic fields and partially radiated away in gravitational waves, the hypermassive neutron star loses its support and collapses to a black hole.Plasma velocities turn around (51.5 ms)Initially the plasma was falling inward, but as the disk of neutron-star debris is accreted onto the black hole, energy is released. This turns the plasma near the black hole poles around and flings it outward.Magnetic field forms a helical funnel (62.5 ms)The fields near the poles of the black hole amplify as they are wound around, creating a funnel that provides the wall of the jet.Jet outflow extends to heights greater than 445 km (64.5 ms)The disk is all accreted and, since the fuel is exhausted, the outflow shuts off (within 100ms)Neutron-Star SuccessPlot showing the gravitational wave signature for one of the authors simulations. The moments of merger of the neutron stars and collapse to a black hole are marked. [Adapted from Ruiz et al. 2016]These simulations show that no initial black hole is needed to launch outflows; a merger of two neutron stars can result in an sGRB-like jet. Another interesting result is that the magnetic field configuration doesnt affect the formation of a jet: neutron stars with magnetic fields confined to their interiors launch jets as effectively as those with pulsar-like magnetic fields. The accretion timescale for both cases is consistent with the duration of an sGRB.While this simulation models milliseconds of real time, its enormously computationally challenging and takes months to simulate. The successes of this simulation represent exciting advances in numerical relativity, as well as in our understanding of the electromagnetic counterparts that may accompany gravitational waves.BonusCheck out this awesome video of the authors simulations. The colors differentiate the plasma density and the white lines depict the pulsar-like magnetic field that initially threads the two merging neutron stars. Watch as the neutron stars evolve through the different stages outlined above, eventually forming a black hole and launching a powerful jet.[Simulations and visualization by M. Ruiz, R. Lang, V. Paschalidis, S. Shapiro and the Illinois Relativity Group REU team: S. Connelly, C. Fan, A. Khan, and P. Wongsutthikoson]CitationMilton Ruiz et al 2016 ApJ 824 L6. doi:10.3847/2041-8205/824/1/L6
In vivo chlorine and sodium MRI of rat brain at 21.1 T.
Schepkin, Victor D; Elumalai, Malathy; Kitchen, Jason A; Qian, Chunqi; Gor'kov, Peter L; Brey, William W
2014-02-01
MR imaging of low-gamma nuclei at the ultrahigh magnetic field of 21.1 T provides a new opportunity for understanding a variety of biological processes. Among these, chlorine and sodium are attracting attention for their involvement in brain function and cancer development. MRI of (35)Cl and (23)Na were performed and relaxation times were measured in vivo in normal rat (n = 3) and in rat with glioma (n = 3) at 21.1 T. The concentrations of both nuclei were evaluated using the center-out back-projection method. T 1 relaxation curve of chlorine in normal rat head was fitted by bi-exponential function (T 1a = 4.8 ms (0.7) T 1b = 24.4 ± 7 ms (0.3) and compared with sodium (T 1 = 41.4 ms). Free induction decays (FID) of chlorine and sodium in vivo were bi-exponential with similar rapidly decaying components of [Formula: see text] ms and [Formula: see text] ms, respectively. Effects of small acquisition matrix and bi-exponential FIDs were assessed for quantification of chlorine (33.2 mM) and sodium (44.4 mM) in rat brain. The study modeled a dramatic effect of the bi-exponential decay on MRI results. The revealed increased chlorine concentration in glioma (~1.5 times) relative to a normal brain correlates with the hypothesis asserting the importance of chlorine for tumor progression.
NASA Astrophysics Data System (ADS)
Fersi, R.; Bouzidi, W.; Bezergheanu, A.; Cizmas, C. B.; Bessais, L.; Mliki, N.
2018-04-01
In this work, Ce2Ni7 type structural PrCo-based films were deposited on Si(1 0 0) substrate by ultra-high (UHV) vacuum evaporation process. The structural and magnetic properties of these films have been performed using X-ray diffraction (XRD), atomic force microscopy (AFM), vibrating sample magnetometer (VSM) and magnetic force microscopy (MFM) techniques. Two effects on structural and magnetic properties of PrCo films have been investigated: the effect of the annealing temperature (Ta) and the effect of the variation of the magnetic X-layer thickness. The as deposited PrCo films have a magnetic coercivity (Hc) of about 40-100 Oe. But after annealing at 600 °C, Hc has increased hight about 9.5 kOe for PrCo(X = 20 nm) and 10.2 kOe for PrCo(X = 50 nm) were observed. The magnetic properties were affected by the thickness due to the morphology, also the relationship between the intergrain exchange coupling (IEC), the size and quantity of the PrCo grains. The hight extrinsic properties of Hc = 10.2 kOe, maximum energy product (BH)max of 5.12 MGOe and remanence ratio Mr /Ms = 0.53 are reported for the PrCo(X = 50 nm) films. These properties are highly desirable for extremely high-density magnetic recording media applications.
Maggi, Pietro; Absinta, Martina; Grammatico, Matteo; Vuolo, Luisa; Emmi, Giacomo; Carlucci, Giovanna; Spagni, Gregorio; Barilaro, Alessandro; Repice, Anna Maria; Emmi, Lorenzo; Prisco, Domenico; Martinelli, Vittorio; Scotti, Roberta; Sadeghi, Niloufar; Perrotta, Gaetano; Sati, Pascal; Dachy, Bernard; Reich, Daniel S; Filippi, Massimo; Massacesi, Luca
2018-02-01
In multiple sclerosis (MS), magnetic resonance imaging (MRI) is a sensitive tool for detecting white matter lesions, but its diagnostic specificity is still suboptimal; ambiguous cases are frequent in clinical practice. Detection of perivenular lesions in the brain (the "central vein sign") improves the pathological specificity of MS diagnosis, but comprehensive evaluation of this MRI biomarker in MS-mimicking inflammatory and/or autoimmune diseases, such as central nervous system (CNS) inflammatory vasculopathies, is lacking. In a multicenter study, we assessed the frequency of perivenular lesions in MS versus systemic autoimmune diseases with CNS involvement and primary angiitis of the CNS (PACNS). In 31 patients with inflammatory CNS vasculopathies and 52 with relapsing-remitting MS, 3-dimensional T2*-weighted and T2-fluid-attenuated inversion recovery images were obtained during a single MRI acquisition after gadolinium injection. For each lesion, the central vein sign was evaluated according to consensus guidelines. For each patient, lesion count, volume, and brain location, as well as fulfillment of dissemination in space MRI criteria, were assessed. MS showed higher frequency of perivenular lesions (median = 88%) than did inflammatory CNS vasculopathies (14%), without overlap between groups or differences between 3T and 1.5T MRI. Among inflammatory vasculopathies, Behçet disease showed the highest median frequency of perivenular lesions (34%), followed by PACNS (14%), antiphospholipid syndromes (12%), Sjögren syndrome (11%), and systemic lupus erythematosus (0%). When a threshold of 50% perivenular lesions was applied, central vein sign discriminated MS from inflammatory vasculopathies with a diagnostic accuracy of 100%. The central vein sign differentiates inflammatory CNS vasculopathies from MS at standard clinical magnetic field strengths. Ann Neurol 2018;83:283-294. © 2018 The Authors Annals of Neurology published by Wiley Periodicals, Inc. on behalf of American Neurological Association.
Robert, Christelle; Huet, Anne-Catherine; Suárez-Pantaleón, Célia; Brasseur, Amaury; Delahaut, Philippe; Gillard, Nathalie
2017-11-01
Recombinant bovine somatotropin (rbST), a synthetic growth hormone, is used to stimulate growth and enhance milk production in dairy cows. Both its use and the sale of dairy products from treated animals are prohibited in the European Union, as well as in Australia, Canada, Japan, and New Zealand, but authorised in several countries (e.g. Brazil, USA). Screening methods involve detecting anti-rbST antibodies (biomarkers) in treated cows. Confirmatory methods are required to prove rbST abuse. The major challenges in determining rbST are its potentially low levels, its high similarity to native bST, and matrix interferences. To overcome these obstacles, we have developed a method involving immunomagnetic precipitation followed by UHPLC-MS/MS for rbST detection. Briefly, protein G magnetic beads pre-coated with an in-house produced monoclonal antibody were added to plasma. Incubation at room temperature allowed rbST present in the sample to bind to the magnetic beads. After that, magnetic beads were isolated by centrifugation and thoroughly washed (PBS, PBS + 0.2% Tween 20). Finally, rbST was released by alkalinisation and the samples were trypsin digested prior to UHPLC-MS/MS analysis in the MRM mode. Validation was done in accordance with European Commission Decision 2002/657/CE. Matrix-matched calibration with internal standards was used. The decision limit (CCα) reached with this approach was 0.11 µg l -1 .
NASA Astrophysics Data System (ADS)
Arian Zad, Hamid; Ananikian, Nerses
2018-04-01
The mixed spin-(1,1/2) Ising–Heisenberg double sawtooth ladder containing a mixture of both spin-1 and spin-1/2 nodal atoms, and the spin-1/2 interstitial dimers are approximately solved by the transfer-matrix method. Here, we study in detail the ground-state phase diagrams, also influences of the bilinear exchange coupling on the rungs and cyclic four-spin exchange interaction in square plaquette of each block on the magnetization and magnetic susceptibility of the suggested ladder at low temperature. Such a double sawtooth ladder may be found in a Shastry-Sutherland lattice-type. In spite of the spin ordering of odd and even blocks being different from each other, due to the commutation relation between all different block Hamiltonians, phase diagrams, magnetization behavior and thermodynamic properties of the model are the same for odd and even blocks. We show that at low temperature, both exchange couplings can change the quality and quantity of the magnetization plateaus versus the magnetic field changes. Specially, we find a new magnetization plateau M/Ms= 5/6 for this model. Besides, we examine the magnetic susceptibility and specific heat of the model in detail. It is proven that behaviors of the magnetization and the magnetic susceptibility coincide at low temperature. The specific heat displays diverse temperature dependencies, which include a Schottky-type peak at a special temperature interval. We observe that with increase of the bilinear exchange coupling on the rungs, second peak temperature dependence grows.
NASA Astrophysics Data System (ADS)
Ustra, A.; Kessouri, P.; Leite, A.; Mendonça, C. A.; Bandeira, N.
2017-12-01
Magnetic minerals in soils and rocks are one way to study biogechemical and paleoenvironmental processes. The ultrafine fraction of these minerals (superparmagnetic (SP) and stable single domain (SSD)) are usually investigated in environmental magnetism studies, since changes in mineralogy, concentration, size and morphology of the magnetic grains can be related to biogeochemical processes. In this study, we use low-field frequency dependent susceptibility (FDS) and isothermal remanent magnetization (IRM) to characterize the magnetic properties of materials in environmental magnetism. Magnetic susceptibility (MS) measurements are frequently used as a proxy of magnetic minerals present in soils and rocks. MS is a complex function of magnetic mineralogy and grain size, as well as magnitude and frequency of the applied field. This work presents a method for inverting low-field FDS data. The inverted parameters can be interpreted in terms of grain size variations of magnetic particles on the SP-SSD transition. This work also presents a method for inverting IRM demagnetization curves, to obtain the saturation magnetization, the individual magnetic moment for an assemblage of ultrafine SP minerals and estimate the concentration of magnetic carriers. IRM magnetization curves can be interpreted as resulting from distinct contributions of different mineral phases, which can be described by Cummulative Log-Gaussian (CLG) distributions. Each acquisition curve provides fundamental parameters that are characteristic of the respective mineral phase. The CLG decomposition is widely used in an interpretation procedure named mineral unmixing. In this work we present an inversion method for mineral unmixing, implementing the genetic algorithm to find the parameters of distinct components. These methodologies have been tested by synthetic models and applied to data from environmental magnetism studies. In this work we apply the proposed methodologies to characterize the magnetic properties of samples from the former Brandywine MD Defense Reutilization and Marketing Office (DRMO). The results from the magnetic properties characterization will provide additional information that may assist the interpretation of the biogeophysical signatures observed at the site.
Investigation of the annealing temperature dependence of the spin pumping in Co20Fe60B20/Pt systems
NASA Astrophysics Data System (ADS)
Belmeguenai, M.; Aitoukaci, K.; Zighem, F.; Gabor, M. S.; Petrisor, T.; Mos, R. B.; Tiusan, C.
2018-03-01
Co20Fe60B20/Pt systems with variable thicknesses of Co20Fe60B20 and of Pt have been sputtered and then annealed at various temperatures (Ta) up to 300 °C. Microstrip line ferromagnetic resonance (MS-FMR) has been used to investigate Co20Fe60B20 and Pt thickness dependencies of the magnetic damping enhancement due to the spin pumping. Using diffusion and ballistic models for spin pumping, the spin mixing conductance and the spin diffusion length have been deduced from the Co20Fe60B20 and the Pt thickness dependencies of the Gilbert damping parameter α of the Co20Fe60B20/Pt heterostructures, respectively. Within the ballistic simple model, both the spin mixing conductance at the CoFeB/Pt interface and the spin-diffusion length of Pt increase with the increasing annealing temperature and show a strong enhancement at 300 °C annealing temperature. In contrast, the spin mixing conductance, which increases with Ta, shows a different trend to the spin diffusion length when using the diffusion model. Moreover, MS-FMR measurements revealed that the effective magnetization varies linearly with the Co20Fe60B20 inverse thickness due to the perpendicular interface anisotropy, which is found to decrease as the annealing temperature increases. It also revealed that the angular dependence of the resonance field is governed by small uniaxial anisotropy which is found to vary linearly with the Co20Fe60B20 inverse thickness of the annealed films, in contrast to that of the as grown ones.
Compact toroid injection into C-2U
NASA Astrophysics Data System (ADS)
Roche, Thomas; Gota, H.; Garate, E.; Asai, T.; Matsumoto, T.; Sekiguchi, J.; Putvinski, S.; Allfrey, I.; Beall, M.; Cordero, M.; Granstedt, E.; Kinley, J.; Morehouse, M.; Sheftman, D.; Valentine, T.; Waggoner, W.; the TAE Team
2015-11-01
Sustainment of an advanced neutral beam-driven FRC for a period in excess of 5 ms is the primary goal of the C-2U machine at Tri Alpha Energy. In addition, a criteria for long-term global sustainment of any magnetically confined fusion reactor is particle refueling. To this end, a magnetized coaxial plasma-gun has been developed. Compact toroids (CT) are to be injected perpendicular to the axial magnetic field of C-2U. To simulate this environment, an experimental test-stand has been constructed. A transverse magnetic field of B ~ 1 kG is established (comparable to the C-2U axial field) and CTs are fired across it. As a minimal requirement, the CT must have energy density greater than that of the magnetic field it is to penetrate, i.e., 1/2 ρv2 >=B2 / 2μ0 . This criteria is easily met and indeed the CTs traverse the test-stand field. A preliminary experiment on C-2U shows the CT also capable of penetrating into FRC plasmas and refueling is observed resulting in a 20 - 30% increase in total particle number per single-pulsed CT injection. Results from test-stand and C-2U experiments will be presented.
The temperature dependence of magnetic anisotropy of Nd-Fe-B thin films
NASA Astrophysics Data System (ADS)
Sato, Takuya; Hashimoto, Ryuji; Tanaka, Yoshitomo; Suzuki, Kenichi; Enokido, Yasushi; Choi, Kyung-Ku; Suzuki, Takao
2018-05-01
The magnetic properties of Nd-Fe-B thin films with the three different compositions (#1: Nd12.6Fe81.5B5.9, #2: Nd14.6Fe78.1B7.4 and #3: Nd22.6Fe66.2B11.2) are discussed. With increasing Nd content, the c-axis orientation along the film normal is enhanced. It is found that sample #2 possesses the saturation magnetization Ms very close to that for Nd2Fe14B over a temperature range from 100 to about 300K. The magnetic anisotropy constant Ku2 for sample #2 is the highest among those samples, but smaller by about 20%, as compared to that for Nd2Fe14B. It is of interest to note that the temperature TR at which Ku1 changes its sign is lower by about 30K as compared to that previously reported for Nd2Fe14B. The reason for this discrepancy is not clear, but could be due to the presence of the minority phases of Nd-rich compounds and also a possible contribution of the magneto-elastic effect to the net magnetic anisotropy.
In vivo sup 31 P-NMR spectroscopy of chronically stimulated canine skeletal muscle
DOE Office of Scientific and Technical Information (OSTI.GOV)
Clark, B.J. III; McCully, A.K.; Subramanian, H.V.
1988-02-01
Chronic stimulation converts skeletal muscle of mixed fiber type to a uniform muscle made up of type I, fatigue-resistant fibers. Here, the bioenergetic correlates of fatigue resistance in conditioned canine latissimus dorsi are assessed with in vivo phosphorus-31 nuclear magnetic resonance ({sup 31}P-NMR) spectroscopy. After chronic electrical stimulation, five dogs underwent {sup 31}P-NMR spectroscopic and isometric tension measurements on conditioned and contralateral control muscle during stimulation for 200, 300, 500, and 800 ms of an 1,100-ms duty cycle. With stimulation, phosphocreatine (PCr) fell proportional to the degree of stimulation in both conditioned and control muscle but fell significantly less inmore » conditioned muscle at all the least intense stimulation period (200 ms). Isometric tension, expressed as a tension time index per gram muscle, was significantly greater in the conditioned muscle at the two longest stimulation periods. The overall small change in PCr and the lack of a plateau in tension observed in the conditioned muscle are similar to that seen in cardiac muscle during increased energy demand. This study indicates that the conditioned muscle's markedly enhanced resistance to fatigue is in part the result of its increased capacity for oxidative phosphorylation.« less
Magnetodielectric effect in CdS nanosheets grown within Na-4 mica
NASA Astrophysics Data System (ADS)
Mandal, Amrita; Mitra, Sreemanta; Datta, Anindya; Banerjee, Sourish; Chakravorty, Dipankar
2012-04-01
CdS nanosheets of thickness 0.6 nm were grown within the interlayer spaces of Na-4 mica. Magnetization measurements carried out in the temperature range 2-300 K showed the composites to have weak ferromagnetic-like properties even at room temperature. The saturation magnetization (MS) at room temperature was found to be higher than that reported for CdS nanoparticles. The higher value of MS may be ascribed to the presence of a large number defects in the present CdS system, due to a large surface to volume ratio in the nanosheets as compared to that of CdS nanoparticles. The nanocomposites exhibited a magnetodielectric effect with a dielectric constant change of 5.3% for a magnetic field of 0.5 T. This occurred due to a combination of magnetoresistance and Maxwell-Wagner effect as delineated in the model developed by Catalan.
NASA Astrophysics Data System (ADS)
Mefteh, Samir; Essefi, Elhoucine; Yaich, Chokri; Jamoussi, Fakher; Medhioub, Mounir
2015-03-01
In order to distinguish the effects of diagenesis, the climate and the depositional environment, the magnetic properties were correlated with some minerals along the NWA-1 well, which crosses the southern subsurface from Cretaceous to Silurian successions. The MS along NWA-1 well shows major picks probably indicating a dramatic change of geochemical and mineralogical composition. Minor picks may be attributed to diagenetic transformations affecting some minerals. The mineralogical analysis shows the presence of illite, kaolinite with some traces of chlorite and smectite. Quartz, calcite, white feldspar, anorthite, dolomite, gypsum and pyrite are identified as associated minerals. The PCA of the different minerals and the magnetic susceptibility shows three different heterogeneous populations. In these populations, the traditional classification of magnetic minerals is not respected. For instance, diamagnetic minerals are positively correlated with MS. This correlation is through indirect causal relation extrapolating the temperature caused by the burial diagenesis. The aim is not totally reached because the handicap is twofold. The XRD diffraction is not able to identify the low amounts of magnetic minerals and the primary mineralogy and magnetic properties are radically modified by post-depositional processes. At the productive well of NWA-1, this overlap is further complicated by hydrocarbons, low grade metamorphism and remagnetization modifying the original magnetic signal.
Clustering Multiple Sclerosis Subgroups with Multifractal Methods and Self-Organizing Map Algorithm
NASA Astrophysics Data System (ADS)
Karaca, Yeliz; Cattani, Carlo
Magnetic resonance imaging (MRI) is the most sensitive method to detect chronic nervous system diseases such as multiple sclerosis (MS). In this paper, Brownian motion Hölder regularity functions (polynomial, periodic (sine), exponential) for 2D image, such as multifractal methods were applied to MR brain images, aiming to easily identify distressed regions, in MS patients. With these regions, we have proposed an MS classification based on the multifractal method by using the Self-Organizing Map (SOM) algorithm. Thus, we obtained a cluster analysis by identifying pixels from distressed regions in MR images through multifractal methods and by diagnosing subgroups of MS patients through artificial neural networks.
Helms, Gunther; Dathe, Henning; Kallenberg, Kai; Dechent, Peter
2008-12-01
An empirical equation for the magnetization transfer (MT) FLASH signal is derived by analogy to dual-excitation FLASH, introducing a novel semiquantitative parameter for MT, the percentage saturation imposed by one MT pulse during TR. This parameter is obtained by a linear transformation of the inverse signal, using two reference experiments of proton density and T(1) weighting. The influence of sequence parameters on the MT saturation was studied. An 8.5-min protocol for brain imaging at 3 T was based on nonselective sagittal 3D-FLASH at 1.25 mm isotropic resolution using partial acquisition techniques (TR/TE/alpha = 25ms/4.9ms/5 degrees or 11ms/4.9ms/15 degrees for the T(1) reference). A 12.8 ms Gaussian MT pulse was applied 2.2 kHz off-resonance with 540 degrees flip angle. The MT saturation maps showed an excellent contrast in the brain due to clearly separated distributions for white and gray matter and cerebrospinal fluid. Within the limits of the approximation (excitation <15 degrees , TR/T(1) less sign 1) the MT term depends mainly on TR, the energy and offset of the MT pulse, but hardly on excitation and T(1) relaxation. It is inherently compensated for inhomogeneities of receive and transmit RF fields. The MT saturation appeared to be a sensitive parameter to depict MS lesions and alterations of normal-appearing white matter. (c) 2008 Wiley-Liss, Inc.
Ultrafast rotation of magnetically levitated macroscopic steel spheres
Schuck, Marcel; Steinert, Daniel; Nussbaumer, Thomas; Kolar, Johann W.
2018-01-01
Our world is increasingly powered by electricity, which is largely converted to or from mechanical energy using electric motors. Several applications have driven the miniaturization of these machines, resulting in high rotational speeds. Although speeds of several hundred thousand revolutions per minute have been used industrially, we report the realization of an electrical motor reaching 40 million rpm to explore the underlying physical boundaries. Millimeter-scale steel spheres, which are levitated and accelerated by magnetic fields inside a vacuum, are used as a rotor. Circumferential speeds exceeding 1000 m/s and centrifugal accelerations of more than 4 × 108 times gravity were reached. The results open up new research possibilities, such as the testing of materials under extreme centrifugal load, and provide insights into the development of future electric drive systems. PMID:29326976
Ferromagnetism in Fe-doped transition metal nitrides
NASA Astrophysics Data System (ADS)
Sharma, Ramesh; Sharma, Yamini
2018-04-01
Early transition metal mononitrides ScN and YN are refractory compounds with high hardness and melting points as well semiconducting properties. The presence of nitrogen vacancies in ScN/YN introduces asymmetric peaks in the density of states close to Fermi level, the same effects can be achieved by doping by Mn or Fe-atoms. Due to the substitution of TM atoms at Sc/Y sites, it was found that the p-d hybridization induces small magnetic moments at both Sc/Y and N sites giving rise to magnetic semiconductors (MS). From the calculated temperature dependent transport properties, the power factor and ZT is found to be lowered for doped ScN whereas it increases for doped YN. It is proposed that these materials have promising applications as spintronics and thermoelectric materials.
Ultrafast rotation of magnetically levitated macroscopic steel spheres.
Schuck, Marcel; Steinert, Daniel; Nussbaumer, Thomas; Kolar, Johann W
2018-01-01
Our world is increasingly powered by electricity, which is largely converted to or from mechanical energy using electric motors. Several applications have driven the miniaturization of these machines, resulting in high rotational speeds. Although speeds of several hundred thousand revolutions per minute have been used industrially, we report the realization of an electrical motor reaching 40 million rpm to explore the underlying physical boundaries. Millimeter-scale steel spheres, which are levitated and accelerated by magnetic fields inside a vacuum, are used as a rotor. Circumferential speeds exceeding 1000 m/s and centrifugal accelerations of more than 4 × 10 8 times gravity were reached. The results open up new research possibilities, such as the testing of materials under extreme centrifugal load, and provide insights into the development of future electric drive systems.
Peng, Chuyu; He, Man; Chen, Beibei; Huang, Lijin; Hu, Bin
2017-11-20
A novel magnetic sulfur-doped porous carbon (MSPC) was fabricated via a simple one-step carbonization of a mixture of sucrose, basic magnesium sulfate whiskers and Fe 3 O 4 @SiO 2 nanoparticles. Due to the high S content, the prepared MSPC possessed high adsorption capacity for Hg 2+ (343 mg g -1 ) with good selectivity. Based on this, a method coupling magnetic solid phase extraction (MSPE) with inductively coupled plasma mass spectrometry (ICP-MS) was developed for the determination of trace Hg 2+ in environmental water samples. Various parameters such as pH, desorption solvent and its concentration, desorption volume and time, sample volume, and adsorption time that affect the determination have been optimized. Under the optimal conditions, a high enrichment factor of 100-fold was obtained, the limit of detection (LOD) was found to be 0.52 pg mL -1 with a relative standard deviation (c = 10 pg mL -1 , n = 7) of 7.1%, and a good linearity was obtained within the concentration range of 2-5000 pg mL -1 for Hg 2+ . Besides, the proposed method has very fast adsorption/desorption kinetics, target Hg 2+ could be rapidly adsorbed on the prepared MSPC in 2 min and desorbed from the MSPC in 2 min with the assistance of a permanent magnet. Therefore, the proposed method of MSPE-ICP-MS exhibits good application potential in the determination of trace Hg 2+ in environmental water samples.
NASA Astrophysics Data System (ADS)
Cui, B. Z.; Marinescu, M.; Liu, J. F.
2014-05-01
This paper reports morphology, structure, and magnetic properties of air-stable soft magnetic FexCo100-x (x = 65, 50, and 34) and Fe50Ni50 (at. %) submicron and nanosize particles fabricated by template-free thermal decomposition of nitrates of Fe, Co, and Ni and subsequent hydrogen reduction. The particle compositions were tuned by modification of the precursor solution concentrations. The as-synthesized Fe-Co and Fe50Ni50 particles have body centered cubic and face centered cubic poly-nanocrystalline structures, respectively. The Fe-Co and Fe50Ni50 particles have particle sizes in the range of 28-200 nm and 70-480 nm, and average grain sizes of 16-29 nm and 20-24 nm, respectively. The particle and grain sizes were controlled by tuning particle composition, and the temperature and time of hydrogen reduction. Saturation magnetization Ms as high as 207-224 emu/g and intrinsic coercivity Hci of 59-228 Oe were obtained in the Fe-Co particles reduced at 550 °C for 90 min. Of special note, the Ms of 224 emu/g (˜2.3 T) obtained in the Fe65Co35 particles is among the highest values for Fe-Co particles reported so far. Ms of 135-137 emu/g and Hci of 59-111 Oe were obtained in the Fe50Ni50 particles reduced at 500 or 550 °C for 20 min.
NASA Astrophysics Data System (ADS)
Irfan, M. I.; Meisel, T.
2012-04-01
Concentration of nickel and chromium in any part of the ecosystem is important for environmental concerns in particular human health due to the reason that some species of them can cause health problem e.g. dermatitis and cancer. Sediment samples collected form a river Vordernberger Bach (Leoben, Austria) in an alpine region and soil samples collected in an area adjacent to steel production unit in same narrow valley were investigated. In previous studies a correlation between magnetic susceptibility values and concentration of nickel and chromium showed that a magnetic susceptibility meter can be used to point out the contaminated areas as in-situ device. The purpose of the whole study is to understand the real (point or diffuse, anthropogenic or geogenic) sources of contamination of soils, water and river sediments through heavy metal deposition. Unseparated, magnetic and non-magnetic fractions of soil samples were investigated for geochemical and mineralogical aspects with XRF, ICP-MS, EMPA, Multi-Functional Kappabridge (MFK1) and laser ablation coupled with ICP-MS. Mineralogical study of sediment samples for several sampling points with higher Ni and Cr content was performed. Sediment samples were sieved below 1.4 mm and then a concentrate of heavy minerals was prepared in the field through panning. Concentrated heavy minerals were then subjected for heavy liquid separation in the laboratory. Separated magnetic and non-magnetic fractions below 0.71/0.1 mm and density greater than 2.9 g/cm3 were selected for mineralogical investigation. The abundance of typical anthropogenic particles, e.g., spherical, tinder, roasted ores, iron and steel mill slag was observed under the microscope. Magnetite (mostly anthropogenic), maghemite, chromspinel, chromite (type I & II), (Ca,Al)-ferrite, wustite, apatite (anthropogenic), olivine mixed crystals, calcium silicate and spinel (anthropogenic) are found in magnetic fraction. Non-magnetic fractions contain hematite, siderite, ankerite, corundum (anthropogenic), garnet, chlorite, titanium oxide minerals (ilmenite, rutile, titanite) and amphibole etc. The observed significant increase in heavy metal content from the source region of the Vordernberger Bach at 1500 m above sea level to the confluence of the Vordernberger Bach with the Mur River at 540 m AMSL can be attributed to anthropogenic influence. As expected, the anthropogenic input is more pronounced in the vicinity of historic and current iron and steel production.
Influences of vanadium on magnetocrystalline anisotropy and magnetic properties of Gd2Co17-xVx
NASA Astrophysics Data System (ADS)
Chu, W. G.; Rao, G. H.; Liu, G. Y.; Yang, H. F.; Liu, W. F.; Ouyang, Z. W.; Feng, X. M.; Liang, J. K.
2002-12-01
Single-phase Gd2Co17-xVx compounds (x=0.0-1.5) crystallizing in the rhombohedral Th2Zn17 structure have been synthesized. The lattice parameters a and c of the compounds increase linearly with increasing V content, and the rate of increase of c is about 2.5 times as large as that of a. Substitution of a small amount of V atoms (x=0.3) for Co atoms leads to the occurrence of uniaxial magnetocrystalline anisotropy of Gd2Co17-xVx. The anisotropy field HA increases drastically with increasing V content. The variations of both the lattice parameters and the magnetocrystalline anisotropy with V content suggest a preferential occupation of the V atoms at the 6c dumbbell site. The Curie temperature TC, saturation moment MS, and average Co moment <μCo> of the compounds decrease greatly as the V content increases. The rapid decrease of TC is essentially attributed to a serious weakening of the Co-Co interactions due to the preferential occupation of the V atoms at the 6c site. The effect of a strong hybridization between the V and Co atoms is plausibly responsible for the decreases of the MS and <μCo>.
MO-F-CAMPUS-I-04: Magnetic Resonance Imaging of An in Vitro 3D Tumor Model
DOE Office of Scientific and Technical Information (OSTI.GOV)
Veiga, C; Long, T; Siow, B
Purpose: To investigate the use of an in vitro 3D tumor model (tumoroid) as a bio-phantom for repetitive and sequential magnetic resonance imaging (MRI) studies. Methods: The tissue engineered tumoroid comprised an artificial cancer mass (ACM) containing 30 million HT29 cancer cells seeded in a collagen type I matrix, whose density was increased by plastic compression (dry/wet weight=40%). The ACM was embedded in an uncompressed collagen gel that mimicked the tumor stroma, and the tumoroid was incubated for 24h before imaging. Images were acquired using the 1T ICON™ (Bruker Corporation, Billerica, MA) MRI scanner. T1 maps were calculated using anmore » IR-RARE sequence (TE=12ms, TR=10000ms, 7 inversion times), while for T2 maps a MSME technique (TR=6000ms, 16 echoes) was used. T1 and T2 fittings were performed using a pixel-wise approach to produce relaxometric parametric maps. Results: The images acquired and corresponding T1 and T2 maps indicate contrast between the ACM and the stroma. T1 was 2500 and 2800ms, while T2 was 520 and 760ms, for the ACM and stroma respectively. The ACM construct was not homogenous and internal features were visible, which can be explained by local gradients of cell and/or collagen density. The viability of the cells was confirmed via confocal microscopy for several days after the imaging session, demonstrating the suitability of the tumoroid for sequential imaging studies. Conclusions: We have engineered a tumor model compatible with repetitive and sequential MRI. We found T1 and T2 contrast between the ACM and stroma using a pre-clinical MRI scanner. The model, which enables controllable cell and matrix densities, has potential for a wide range of applications in radiotherapy, such as to study tumor progression and to validate imaging biomarkers. Further work is necessary to understand the mechanisms behind the contrast achieved, and to correlate findings with biology and histology data.« less
Design and evaluation of noise suppression sheet for GHz band utilizing magneto-elastic effect
NASA Astrophysics Data System (ADS)
Igarashi, Toshiyuki; Kondo, Koichi; Yoshida, Shigeyoshi
2017-12-01
Feasibility of realizing a noise suppression sheet (NSS) coping with the low SHF band such as the 5 GHz band was investigated, which was composed of soft magnetic metal flakes dispersed in a polymer. For suppressing noises, the higher frequency one of the bimodal frequency dispersion (lower frequency one: Dispersion DII, higher frequency one: Dispersion DIII) seen in the imaginary permeability (μ″; magnetic loss component) spectrum of the NSS was aimed to utilize. Referring to the previous finding that Dispersion DIII is originated from a magneto-elastic effect, several magnetic composite sheets were prepared using various alloy flakes with different saturation magnetostriction (λs), and their frequency (fr(DIII)) and magnitude (μ″(DIII)) of Dispersion DIII were investigated. It was found that the NSS containing flakes with higher λs exhibited higher fr(DIII) and higher μ″(DIII)/μ″(DII), which was ratio of μ″(DIII) to the magnitude of Dispersion DII (μ″(DII)). The fr(DIII) for the NSS having the highest λs containing Fe-Co alloy flake reached 7.45 GHz and μ″ in the 5 GHz band was approximately twice as high as the conventional NSS containing Fe-Si-Al alloy flake. For transmission attenuation power ratio (Rtp) when an NSS was placed on a microstrip line with characteristic impedance of 50 Ω, NSS with larger fr(DIII)2 · μ″(DIII) ∝ Ms2 (Ms: saturation magnetization), which theoretically gave the frequency limit of imaginary permeability for a thin film, exhibited larger Rtp in the low SHF band. These results suggested that an NSS containing a magnetic flake material with both large λs and Ms was suitable for suppressing low SHF band noises.
NASA Astrophysics Data System (ADS)
Tse, P. W.; Liu, X. C.; Liu, Z. H.; Wu, B.; He, C. F.; Wang, X. J.
2011-05-01
Magnetostrictive sensors (MsSs) that can excite and receive guided waves are commonly used in detecting defects that may occur in cables and strands for supporting heavy structures. A conventional MsS has a hard sensing coil that is wound onto a bobbin with electric wires to generate the necessary dynamic magnetic field to excite the desired guided waves. This tailor-made hard coil is usually bulky and is not flexible enough to fit steel strands of various sizes. The conventional MsS also cannot be mounted to any steel strand that does not have a free end to allow the bobbin to pass through the structure of the tested strand. Such inflexibilities limit the use of conventional MsSs in practical situations. To solve these limitations, an innovative type of coil, called a flexible printed coil (FPC), which is made out of flexible printed film, has been designed to replace the inflexible hard coil. The flexible structure of the FPC ensures that the new MsS can be easily installed on and removed from steel strands with different diameters and without free ends. Moreover, the FPC-based MsS can be wrapped into multiple layers due to its thin and flexible design. Although multi-layer FPC creates a minor asymmetry in the dynamic magnetic field, the results of finite element analysis and experiments confirm that the longitudinal guided waves excited by a FPC-based MsS are comparable to those excited by a conventional hard coil MsS. No significant reduction in defect inspection performance was found; in fact, further advantages were identified when using the FPC-based MsS. When acting as the transmitter, the innovative FPC-based MsS can cover a longer inspection length of strand. When acting as the receiver, the FPC-based MsS is more sensitive to smaller defects that are impossible to detect using a hard coil MsS. Hence, the multi-layer FPC-based MsS has great potential for replacing the conventional hard coil MsS because of its convenient installation, and ease of fitting to different strand diameters; it is smaller, and, most importantly, performs much better in strand defect detection.
NASA Technical Reports Server (NTRS)
Bentley, C. R.; Ritzwoller, M. H.
1983-01-01
Data selection and reduction procedures are described by which scalar and vector magnetic anomaly maps are constructed. The scalar and vertical magnetic anomalies are believed to be generated mainly in the Earth's crust. The horizontal anomalies are believed to be mainly due to short-period field-aligned currents. The correlation of scalar magnetic anomalies with known oceanic structure is remarkable -- magnetic highs are associated with oceanic ridges and magnetic lows with abyssal plains. The correlation between anomalies and continental geology is not so clear.
Nagao, Michinobu; Yamasaki, Yuzo; Kawanami, Satoshi; Kamitani, Takeshi; Sagiyama, Koji; Higo, Taiki; Ide, Tomomi; Takemura, Atsushi; Ishizaki, Umiko; Fukushima, Kenji; Watanabe, Yuji; Honda, Hiroshi
2017-06-01
Quantification of myocardial oxygenation (MO) in heart failure (HF) has been less than satisfactory. This has necessitated the use of invasive techniques to measure MO directly or to determine the oxygen demand during exercise using the cardiopulmonary exercise (CPX) test. We propose a new quantification method for MO using blood-oxygen-level-dependent (BOLD) myocardial T2* magnetic resonance imaging (M-T2* MRI), and investigate its correlation with CPX results. Thirty patients with refractory HF who underwent cardiac MRI and CPX test for heart transplantation, and 24 healthy, age-matched volunteers as controls were enrolled. M-T2* imaging was performed using a 3-Tesla and multi-echo gradient-echo sequence. M-T2* was calculated by fitting the signal intensity data for the mid-left ventricular septum to a decay curve. M-T2* was measured under room-air (T2*-air) and after inhalation of oxygen for 10min at a flow rate of 10L/min (T2*-oxy). MO was defined as the difference between the two values (ΔT2*). Changes in M-T2* at the two conditions and ΔT2* between the two groups were compared. Correlation between ΔT2* and CPX results was analyzed using the Pearson coefficient. T2*-oxy was significantly greater than T2*-air in patients with HF (29.9±7.3ms vs. 26.7±6.0ms, p<0.001), whereas no such difference was observed in controls (25.5±4.0ms vs. 25.4±4.4ms). ΔT2* was significantly greater for patients with HF than for controls (3.2±4.5ms vs. -0.1±1.3ms, p<0.001). A significant correlation between ΔT2* and CPX results (peak VO 2 , r=-0.46, p<0.05; O 2 pulse, r=-0.54, p<0.005) was observed. ΔT2* is increased T2*-oxy is greater in patients with HF, and is correlated with oxygen metabolism during exercise as measured by the CPX test. Hence, ΔT2* can be used as a surrogate marker of MO instead of CPX test. Copyright © 2017 Elsevier Inc. All rights reserved.
Xie, Baogang; Zhang, Zhirong; Gong, Tao; Zhang, Ningning; Wang, Huiyun; Zou, Huiqing
2015-01-01
Identification of the bioactive ingredient from traditional Chinese medicine (TCM) remains a challenging task by traditional approach that focuses on chemical isolation coupled with biological activity screening. Here, we present a metabonomics-based approach for bioactive ingredient discovery in LiuWeiDiHuang pills (LWPs). First, a non-targeted high-performance liquid chromatography ultraviolet (HPLC-UV) profiling of rat urine was used to discriminate urinary profiling intervened by LWPs. Orthogonal partial least-squares discriminant analysis (OPLS-DA) revealed that eight chromatographic peaks made a significant contribution to the classification of the LWPs group and the control group. Five of these chromatographic peaks were successfully isolated and identified as hippurate, genistein (GT), daidzein (DZ), and glucuronide conjugate of GT and that of DZ by mass spectroscopy (MS). Subsequently, we found that LWPs significantly decreased the activity of intestinal β-glucuronidase by 18 % and exerted a dose-dependent inhibitory effect on rat liver lysosomal fraction, suggesting that LWPs were a β-glucuronidase inhibitor. In the end, by inhibiting β-glucuronidase-guided isolation, D-glucaro-1,4-lactone, a previously unreported ingredient of LWPs, was identified by MS, MS/MS, and nuclear magnetic resonance spectroscopy. Our findings indicated that metabonomics might increase research productivity toward the drug targets and/or bioactive compounds from TCM.
Messina, Irene; Cattaneo, Luigi; Venuti, Paola; de Pisapia, Nicola; Serra, Mauro; Esposito, Gianluca; Rigo, Paola; Farneti, Alessandra; Bornstein, Marc H.
2016-01-01
Neuroimaging reveals that infant cries activate parts of the premotor cortical system. To validate this effect in a more direct way, we used event-related transcranial magnetic stimulation (TMS). Here, we investigated the presence and the time course of modulation of motor cortex excitability in young adults who listened to infant cries. Specifically, we recorded motor evoked potentials (MEPs) from the biceps brachii (BB) and interosseus dorsalis primus (ID1) muscles as produced by TMS delivered from 0 to 250 ms after sound onset in six steps of 50 ms in 10 females and 10 males. We observed an excitatory modulation of MEPs at 100 ms from the onset of infant cry specific to females and to the ID1 muscle. We regard this modulation as a response to natural cry sounds because it was attenuated to stimuli increasingly different from natural cry and absent in a separate group of females who listened to non-cry stimuli physically matched to natural infant cries. Furthermore, the 100-ms latency of this response is not compatible with a voluntary reaction to the stimulus but suggests an automatic, bottom-up audiomotor association. The brains of adult females appear to be tuned to respond to infant cries with automatic motor excitation. PMID:26779061
NASA Technical Reports Server (NTRS)
Mikellides, Ioannis G.; Katz, Ira; Hofer, Richard R.; Goebel, Dan M.
2012-01-01
A proof-of-principle effort to demonstrate a technique by which erosion of the acceleration channel in Hall thrusters of the magnetic-layer type can be eliminated has been completed. The first principles of the technique, now known as "magnetic shielding," were derived based on the findings of numerical simulations in 2-D axisymmetric geometry. The simulations, in turn, guided the modification of an existing 6-kW laboratory Hall thruster. This magnetically shielded (MS) thruster was then built and tested. Because neither theory nor experiment alone can validate fully the first principles of the technique, the objective of the 2-yr effort was twofold: (1) to demonstrate in the laboratory that the erosion rates can be reduced by >order of magnitude, and (2) to demonstrate that the near-wall plasma properties can be altered according to the theoretical predictions. This paper concludes the demonstration of magnetic shielding by reporting on a wide range of comparisons between results from numerical simulations and laboratory diagnostics. Collectively, we find that the comparisons validate the theory. Near the walls of the MS thruster, theory and experiment agree: (1) the plasma potential has been sustained at values near the discharge voltage, and (2) the electron temperature has been lowered by at least 2.5-3 times compared to the unshielded (US) thruster. Also, based on carbon deposition measurements, the erosion rates at the inner and outer walls of the MS thruster are found to be lower by at least 2300 and 1875 times, respectively. Erosion was so low along these walls that the rates were below the resolution of the profilometer. Using a sputtering yield model with an energy threshold of 25 V, the simulations predict a reduction of 600 at the MS inner wall. At the outer wall ion energies are computed to be below 25 V, for which case we set the erosion to zero in the simulations. When a 50-V threshold is used the computed ion energies are below the threshold at both sides of the channel. Uncertainties, sensitivities and differences between theory and experiment are also discussed.
Preliminary design of a superconducting coil array for NASA prototype magnetic balance. M.S. Thesis
NASA Technical Reports Server (NTRS)
Alishahi, M. M.
1980-01-01
Using a computer program a partly optimized configuration for a supeconducting version of side and lift coil system of NASA-MIT prototype is presented. Cable size for the mentioned coils and also for superconducting drag and magnetizing coils regarding the overall computed field was determined.
Parameters of loop-controlled magnetic rheology drive for segmented large mirror
NASA Astrophysics Data System (ADS)
Deulin, Eugeni A.; Mikhailov, Valeri P.; Eliseev, Oleg N.; Sytchev, Victor V.
2000-07-01
The design, parameters and the amplitude-frequency analysis of the new magnetic rheology (MR) drive are presented. The combination of hydrostatic carrier, MR hydraulic loop control, elastic thin wall seal joined in a single unit ensures small positioning error nm and small time of response T
Delaware Consortium for Undergraduate Minority Training in Prostate Cancer
2008-02-01
Nanoparticle Hyperthermia Induced Wound-Healing Assay in Prostate Cancer Cells. Adaire T. Heady, Michael J. Bonder, Ph.D., David J. DeGraff, M.S., Robert...6 Development of Magnetic Nanoparticle Hyperthermia ...George C. Hadjipanayis, Ph.D., Delaware State University, Dover, DE, USA, University of Delaware, Neware, DE, USA The use of magnetic nanoparticle
Application of the McDonald MRI criteria in multiple sclerosis.
Chan, Ling Ling; Sitoh, Yih Yian; Chong, June; See, Siew Ju; Umapathi, Thirugnanam N; Lim, Shih Hui; Ong, Benjamin
2007-08-01
The aim of this study was to assess the sensitivity of McDonald's magnetic resonance imaging (MRI) criteria for the diagnosis of multiple sclerosis (MS) in a group of Asian patients diagnosed with clinically definite MS, based on lesion characterisation on MRI scans. Forty-nine patients from 3 major neurological institutions were classified as having Asian- or Western-type MS based on clinical assessment. Each MRI scan was reviewed by 2 neuroradiologists for the presence and characteristics of brain and spinal lesions. The McDonald's MRI criteria were then applied and its sensitivity evaluated. Nine patients were excluded, leaving 34 females and 6 males who were dominantly Chinese (90%), with a mean age of 36.2 years. The MRI brain and spinal findings were detailed and tabulated. Statistically significant differences (P <0.01) in MRI brain findings and sensitivity of McDonald's MRI criteria were found between our Asian- and Western-type MS patients. The diagnostic yield of McDonald's MRI criteria increased by 20% when we substituted a cord for a brain lesion, and applied the substitution for enhancing cord lesions as well. The diagnosis is more likely to be made when using McDonald MRI criteria based on brain findings, in a patient who presents clinically with Western-type MS. The provision for substitution of "one brain for a spinal lesion" is helpful in Asian-type MS, where there is preponderance of spinal lesion load. Our findings suggest that minor modifications in the interpretation of McDonald's MRI criteria have significant impact on the diagnosis in patients clinically presenting as Asian-type MS, with potential bearing on their subsequent management.
Low Frequency Plasma Oscillations in a 6-kW Magnetically Shielded Hall Thruster
NASA Technical Reports Server (NTRS)
Jorns, Benjamin A.; Hofery, Richard R.
2013-01-01
The oscillations from 0-100 kHz in a 6-kW magnetically shielded thruster are experimen- tally characterized. Changes in plasma parameters that result from the magnetic shielding of Hall thrusters have the potential to significantly alter thruster transients. A detailed investigation of the resulting oscillations is necessary both for the purpose of determin- ing the underlying physical processes governing time-dependent behavior in magnetically shielded thrusters as well as for improving thruster models. In this investigation, a high speed camera and a translating ion saturation probe are employed to examine the spatial extent and nature of oscillations from 0-100 kHz in the H6MS thruster. Two modes are identified at 8 kHz and 75-90 kHz. The low frequency mode is azimuthally uniform across the thruster face while the high frequency oscillation is concentrated close to the thruster centerline with an m = 1 azimuthal dependence. These experimental results are discussed in the context of wave theory as well as published observations from an unshielded variant of the H6MS thruster.
Proposed Stages of Myocardial Phenotype Development in Fabry Disease.
Nordin, Sabrina; Kozor, Rebecca; Medina-Menacho, Katia; Abdel-Gadir, Amna; Baig, Shanat; Sado, Daniel M; Lobascio, Ilaria; Murphy, Elaine; Lachmann, Robin H; Mehta, Atul; Edwards, Nicola C; Ramaswami, Uma; Steeds, Richard P; Hughes, Derralynn; Moon, James C
2018-05-11
The authors sought to explore the Fabry myocardium in relation to storage, age, sex, structure, function, electrocardiogram changes, blood biomarkers, and inflammation/fibrosis. Fabry disease (FD) is a rare, x-linked lysosomal storage disorder. Mortality is mainly cardiovascular with men exhibiting cardiac symptoms earlier than women. By cardiovascular magnetic resonance, native T1 is low in FD because of sphingolipid accumulation. A prospective, observational study of 182 FD (167 adults, 15 children; mean age 42 ± 17 years, 37% male) who underwent cardiovascular magnetic resonance including native T1, late gadolinium enhancement (LGE), and extracellular volume fraction, 12-lead electrocardiogram, and blood biomarkers (troponin and N-terminal pro-brain natriuretic peptide). In children, T1 was never below the normal range, but was lower with age (9 ms/year, r = -0.78 children; r = -0.41 whole cohort; both p < 0.001). Over the whole cohort, the T1 reduction with age was greater and more marked in men (men: -1.9 ms/year, r = -0.51, p < 0.001; women: -1.4 ms/year, r = -0.47 women, p < 0.001). Left ventricular hypertrophy (LVH), LGE, and electrocardiogram abnormalities occur earlier in men. Once LVH occurs, T1 demonstrates major sex dimorphism: with increasing LVH in women, T1 and LVH become uncorrelated (r = -0.239, p = 0.196) but in men, the correlation reverses and T1 increases (toward normal) with LVH (r = 0.631, p < 0.001), a U-shaped relationship of T1 to indexed left ventricular mass in men. These data suggest that myocyte storage starts in childhood and accumulates faster in men before triggering 2 processes: a sex-independent scar/inflammation regional response (LGE) and, in men, apparent myocyte hypertrophy diluting the T1 lowering of sphingolipid. Copyright © 2018 American College of Cardiology Foundation. Published by Elsevier Inc. All rights reserved.
Carrick, David; Haig, Caroline; Rauhalammi, Sam; Ahmed, Nadeem; Mordi, Ify; McEntegart, Margaret; Petrie, Mark C; Eteiba, Hany; Hood, Stuart; Watkins, Stuart; Lindsay, Mitchell; Mahrous, Ahmed; Ford, Ian; Tzemos, Niko; Sattar, Naveed; Welsh, Paul; Radjenovic, Aleksandra; Oldroyd, Keith G; Berry, Colin
2016-04-01
To assess the prognostic significance of infarct core tissue characteristics using cardiac magnetic resonance (CMR) imaging in survivors of acute ST-elevation myocardial infarction (STEMI). We performed an observational prospective single centre cohort study in 300 reperfused STEMI patients (mean ± SD age 59 ± 12 years, 74% male) who underwent CMR 2 days and 6 months post-myocardial infarction (n = 267). Native T1 was measured in myocardial regions of interest (n = 288). Adverse remodelling was defined as an increase in left ventricular (LV) end-diastolic volume ≥20% at 6 months. All-cause death or first heart failure hospitalization was a pre-specified outcome that was assessed during follow-up (median duration 845 days). One hundred and sixty (56%) patients had a hypo-intense infarct core disclosed by native T1. In multivariable regression, infarct core native T1 was inversely associated with adverse remodelling [odds ratio (95% confidence interval (CI)] per 10 ms reduction in native T1: 0.91 (0.82, 0.00); P = 0.061). Thirty (10.4%) of 288 patients died or experienced a heart failure event and 13 of these events occurred post-discharge. Native T1 values (ms) within the hypo-intense infarct core (n = 160 STEMI patients) were inversely associated with the risk of all-cause death or first hospitalization for heart failure post-discharge (for a 10 ms increase in native T1: hazard ratio 0.730, 95% CI 0.617, 0.863; P < 0.001) including after adjustment for left ventricular ejection fraction, infarct core T2 and myocardial haemorrhage. The prognostic results for microvascular obstruction were similar. Infarct core native T1 represents a novel non-contrast CMR biomarker with potential for infarct characterization and prognostication in STEMI survivors. Confirmatory studies are warranted. CLINICALTRIALS. NCT02072850. © The Author 2015. Published by Oxford University Press on behalf of the European Society of Cardiology.
2014-09-01
and Subpial Pathology in Multiple Sclerosis by Combined PET and MRI PRINCIPAL INVESTIGATOR: Dr. Caterina Mainero...studies in multiple sclerosis (MS) suggested that cortical demyelinating lesions, which are hardly detected in vivo on conventional magnetic resonance...disease progression in many MS cases. 15. SUBJECT TERMS Multiple sclerosis ; cortex; cortical sulci; neuroinflammation; microglia; cortical
High-Time-Resolution Study of Magnetic Holes in the Solar Wind
NASA Technical Reports Server (NTRS)
Lazarus, Alan; Kasper, Justin; Stevens, Michael
2003-01-01
The objectives of this investigation are to determine the internal plasma structure of kinetic-scale and larger scale magnetic holes, and to determine their stability, their source mechanism(s), and their spatial extent. It is also of importance to determine the relationship between kinetic-scale holes and long-duration holes. As smaller and smaller magnetic depressions are investigated in order to make this a complete study, a robust criterion is necessary for distinguishing magnetic holes from random or unresolvable fluctuations in the interplanetary magnetic field. In order to resolve this ambiguity, we obtained from the MFI experiments magnetic field measurements from the WIND spacecraft at a time resolution of 46 to 184 ms over certain periods. We have also devised a measure of certainty for magnetic hole detections. The certainty factor, q, is defined as the difference between the mean magnetic field in the hole and the local magnetic field, in units of the local standard deviation of the field strength. For fullest generality, it is necessary to calculate this q over the range of available scales of interest, from 60 ms up to 300 s. This technique establishes a two dimensional matrix of relative probabilities that a hole of some duration (d) might exist in the data set at a given time (t). In identifying q-peaks in time and duration, we also come upon a natural method for distinguishing holes with internal structure from multiple holes in close proximity or holes nested inside of others. If two q-peaks are more than a half-width apart, they are simply said to be separate events.
Monthly oral methylprednisolone pulse treatment in progressive multiple sclerosis.
Ratzer, Rikke; Iversen, Pernille; Börnsen, Lars; Dyrby, Tim B; Romme Christensen, Jeppe; Ammitzbøll, Cecilie; Madsen, Camilla Gøbel; Garde, Ellen; Lyksborg, Mark; Andersen, Birgit; Hyldstrup, Lars; Sørensen, Per Soelberg; Siebner, Hartwig R; Sellebjerg, Finn
2016-06-01
There is a large unmet need for treatments for patients with progressive multiple sclerosis (MS). Phase 2 studies with cerebrospinal fluid (CSF) biomarker outcomes may be well suited for the initial evaluation of efficacious treatments. To evaluate the effect of monthly oral methylprednisolone pulse treatment on intrathecal inflammation in progressive MS. In this open-label phase 2A study, 15 primary progressive and 15 secondary progressive MS patients received oral methylprednisolone pulse treatment for 60 weeks. Primary outcome was changes in CSF concentrations of osteopontin. Secondary outcomes were other CSF biomarkers of inflammation, axonal damage and demyelination; clinical scores; magnetic resonance imaging measures of disease activity, magnetization transfer ratio (MTR) and diffusion tensor imaging (DTI); motor evoked potentials; and bone density scans. We found no change in the CSF concentration of osteopontin, but we observed significant improvement in clinical scores, MTR, DTI and some secondary CSF outcome measures. Adverse events were well-known side effects to methylprednisolone. Monthly methylprednisolone pulse treatment was safe, but had no effect on the primary outcome. However, improvements in secondary clinical and MRI outcome measures suggest that this treatment regimen may have a beneficial effect in progressive MS. © The Author(s), 2015.
Zittel, S; Helmich, R C; Demiralay, C; Münchau, A; Bäumer, T
2015-08-01
Previous studies indicated that sensorimotor integration and plasticity of the sensorimotor system are impaired in dystonia patients. We investigated motor evoked potential amplitudes and short latency afferent inhibition to examine corticospinal excitability and cortical sensorimotor integration, before and after inhibitory 1 Hz repetitive transcranial magnetic stimulation over primary sensory and primary motor cortex in patients with cervical dystonia (n = 12). Motor evoked potentials were recorded from the right first dorsal interosseous muscle after application of unconditioned transcranial magnetic test stimuli and after previous conditioning electrical stimulation of the right index finger at short interstimulus intervals of 25, 30 and 40 ms. Results were compared to a group of healthy age-matched controls. At baseline, motor evoked potential amplitudes did not differ between groups. Short latency afferent inhibition was reduced in cervical dystonia patients compared to healthy controls. Inhibitory 1 Hz sensory cortex repetitive transcranial magnetic stimulation but not motor cortex repetitive transcranial magnetic stimulation increased motor evoked potential amplitudes in cervical dystonia patients. Additionally, both 1 Hz repetitive transcranial magnetic stimulation over primary sensory and primary motor cortex normalized short latency afferent inhibition in these patients. In healthy subjects, sensory repetitive transcranial magnetic stimulation had no influence on motor evoked potential amplitudes and short latency afferent inhibition. Plasticity of sensorimotor circuits is altered in cervical dystonia patients.
Facile synthesis and magnetorheological properties of superparamagnetic CoFe2O4/GO nanocomposites
NASA Astrophysics Data System (ADS)
Wang, Guangshuo; Ma, Yingying; Dong, Xufeng; Tong, Yu; Zhang, Lina; Mu, Jingbo; Bai, Yongmei; Hou, Junxian; Che, Hongwei; Zhang, Xiaoliang
2015-12-01
In this study, cobalt ferrite/graphene oxide (CoFe2O4/GO) nanocomposites were synthesized successfully by a facile sonochemical method. The microstructure and physical properties of CoFe2O4/GO nanocomposites were investigated in detail by TEM, XRD and SQUID. It was found that GO nanosheets were fully exfoliated and decorated homogeneously with CoFe2O4 nanoparticles having diameters of 8∼15 nm. The field-dependent magnetization curve indicated superparamagnetic behavior of as-prepared CoFe2O4/GO with saturation magnetization (Ms) of 34.9 emu/g at room temperature. The ferrofluid was prepared by the obtained CoFe2O4/GO with 25 wt% particles and its magnetorheological (MR) properties were tested using a Physica MCR301 rheometer fitted with a magneto-rheological module. The CoFe2O4/GO-based ferrofluid exhibited typical MR effect with increasing viscosity, shear stress and yield stress depending on the applied magnetic field strength.
Magnetic studies of melt spun NdFeAl-C alloys
NASA Astrophysics Data System (ADS)
Rodríguez Torres, C. E.; Cabrera, A. F.; Sánchez, F. H.; Billoni, O. V.; Urreta, S. E.; Fabietti, L. M.
2004-12-01
Alloys with compositions Nd 60-xC xFe 30Al 10 ( x=0, 1, 5 and 10) were processed by melt spinning at a tangential speed of 5 m/s. The as-cast ribbons were characterized by X-ray diffraction, Mössbauer Effect spectroscopy and their room temperature hysteresis loops. The substitution of Nd by C is found to affect the phase selection, from mainly DHCP-Nd for x=0 to DHCP-Nd /FCC-Nd for the other ones. Mössbauer spectra of all the as-cast samples indicate that Fe is present in crystalline magnetic phases as well as in a paramagnetic one. The major crystalline phase was identified as a μ-type (or A1) metastable phase, which is reported to have a large anisotropy field and a relatively high saturation polarization. Interstitial C stabilizes the μ-type phase and improves its average hyperfine field. The magnetic measurements display an increase of coercivity and remanence with the C concentration.
Weingärtner, Sebastian; Meßner, Nadja M; Zöllner, Frank G; Akçakaya, Mehmet; Schad, Lothar R
2017-08-01
To study the feasibility of black-blood contrast in native T 1 mapping for reduction of partial voluming at the blood-myocardium interface. A saturation pulse prepared heart-rate-independent inversion recovery (SAPPHIRE) T 1 mapping sequence was combined with motion-sensitized driven-equilibrium (MSDE) blood suppression for black-blood T 1 mapping at 3 Tesla. Phantom scans were performed to assess the T 1 time accuracy. In vivo black-blood and conventional SAPPHIRE T 1 mapping was performed in eight healthy subjects and analyzed for T 1 times, precision, and inter- and intraobserver variability. Furthermore, manually drawn regions of interest (ROIs) in all T 1 maps were dilated and eroded to analyze the dependence of septal T 1 times on the ROI thickness. Phantom results and in vivo myocardial T 1 times show comparable accuracy with black-blood compared to conventional SAPPHIRE (in vivo: black-blood: 1562 ± 56 ms vs. conventional: 1583 ± 58 ms, P = 0.20); Using black-blood SAPPHIRE precision was significantly lower (standard deviation: 133.9 ± 24.6 ms vs. 63.1 ± 6.4 ms, P < .0001), and blood T 1 time measurement was not possible. Significantly increased interobserver interclass correlation coefficient (ICC) (0.996 vs. 0.967, P = 0.011) and similar intraobserver ICC (0.979 vs. 0.939, P = 0.11) was obtained with the black-blood sequence. Conventional SAPPHIRE showed strong dependence on the ROI thickness (R 2 = 0.99). No such trend was observed using the black-blood approach (R 2 = 0.29). Black-blood SAPPHIRE successfully eliminates partial voluming at the blood pool in native myocardial T 1 mapping while providing accurate T 1 times, albeit at a reduced precision. Magn Reson Med 78:484-493, 2017. © 2016 International Society for Magnetic Resonance in Medicine. © 2016 International Society for Magnetic Resonance in Medicine.
Floré, Vincent; Claus, Piet; Antoons, Gudrun; Oosterhoff, Peter; Holemans, Patricia; Vos, Marc A; Sipido, Karin R; Willems, Rik
2011-07-01
Repolarization variability is considered to predict sudden cardiac death. T-wave alternans (TWA) has been the subject of exhaustive research, whereas beat-to-beat variability of repolarization (BVR) is a new parameter that possibly predicts proarrhythmia. How these parameters interact has not been tested. The purpose of this study was to compare TWA and BVR as predictors of proarrhythmic substrate early after myocardial infarction (MI). In nine pigs, MI was induced by 1-hour occlusion of the left anterior descending coronary artery. Cardiac magnetic resonance imaging was performed at day 21. Six sham pigs served as control. Spectral TWA was tested during right atrial pacing before induction of MI and after 21 days. BVR was calculated from 60 consecutive QT intervals. Magnetic resonance imaging showed transmural MI. TWA was negative in all pigs at clinical threshold rate and equally present in MI versus sham pigs at higher rates (170 bpm: 55% vs 50% positive TWA). In MI pigs, BVR of QT intervals increased significantly during acute ischemia (2.44 ± 0.43 ms vs 3.55 ± 0.41 ms, P <.01) and even more on day 21 (5.80 ± 1.12 ms), but it differed significantly from sham (2.14 ± 0.54 ms, P <.01). A clinical ventricular tachycardia induction protocol was positive in 2 of 8 MI pigs and in none of 6 shams. In early remodeling after MI, BVR at intrinsic heart rate was a consistent phenomenon, whereas TWA during atrial pacing or baseline QT-interval changes were not. TWA and BVR could reflect different post-MI remodeling processes. BVR may be a new technique for predicting a potentially proarrhythmic substrate in the early postinfarction period. Copyright © 2011 Heart Rhythm Society. Published by Elsevier Inc. All rights reserved.
NASA Astrophysics Data System (ADS)
Hira, Uzma; Sher, Falak
2018-04-01
In this study, we have investigated the structural, magnetic and thermoelectric properties of La0.4Bi0.4Ca0.2Mn1-xCoxO3 (0 ≤ x ≤ 0.3) manganites. The crystallographic parameters of samples were determined by the Rietveld refinement of powder X-ray diffraction data. It was observed that Co doping results in change of crystal structures from orthorhombic (space group: Pbnm) to rhombohedral (space group: R-3c) symmetry. Scanning electron microscopy (SEM) images show smooth, clean and densified structures, depicting good crystallinity of samples. The zero field cooled (ZFC) and field cooled (FC) magnetization data were collected in the temperature range 5 to 300 K under an applied magnetic field of 0.1 Tesla. The analysis of temperature dependent magnetization data reveals all samples to be ferromagnetic with Curie temperatures around ∼77 K. The magnetic hysteresis loops, collected at 5 K, show that the saturation magnetization (MS) values decrease from 43 emu/g to 14 emu/g with increase in Co doping. The high temperature thermoelectric properties of all samples are characteristic of a semiconducting behavior, the small polaron hopping model fitting well with the temperature dependent electrical resistivity (ρ) and thermopower (S) data. The thermopower values change sign from positive to negative as temperature is increased from 313 K to 680 K. The maximum thermoelectric power factor (PF = S2/ρ) obtained for x = 0.3 sample at 313 K is 4.60 μW/mK2, is much higher than for the undoped sample.
Shaw, Jared B; Gorshkov, Mikhail V; Wu, Qinghao; Paša-Tolić, Ljiljana
2018-05-01
Mass spectrometric characterization of large biomolecules, such as intact proteins, requires the specificity afforded by ultrahigh resolution mass measurements performed at both the intact mass and product ion levels. Although the performance of time-of-flight mass analyzers is steadily increasing, the choice of mass analyzer for large biomolecules (e.g., proteins >50 kDa) is generally limited to the Fourier transform family of mass analyzers such as Orbitrap and ion cyclotron resonance (FTICR-MS), with the latter providing unmatched mass resolving power and measurement accuracy. Yet, protein analyses using FTMS are largely hindered by the low acquisition rates of spectra with ultrahigh resolving power. Frequency multiple detection schemes enable FTICR-MS to overcome this fundamental barrier and achieve resolving powers and acquisition speeds 4× greater than the limits imposed by magnetic field strength. Here we expand upon earlier work on the implementation of this technique for biomolecular characterization. We report the coupling of 21T FTICR-MS, 4X frequency multiplication, ion trapping field harmonization technology, and spectral data processing methods to achieve unprecedented acquisition rates and resolving power in mass spectrometry of large intact proteins. Isotopically resolved spectra of multiply charged ubiquitin ions were acquired using detection periods as short as 12 ms. Large proteins such as apo-transferrin (MW = 78 kDa) and monoclonal antibody (MW = 150 kDa) were isotopically resolved with detection periods of 384 and 768 ms, respectively. These results illustrate the future capability of accurate characterization of large proteins on time scales compatible with online separations.
Bisecco, Alvino; Rocca, Maria A; Pagani, Elisabetta; Mancini, Laura; Enzinger, Christian; Gallo, Antonio; Vrenken, Hugo; Stromillo, Maria Laura; Copetti, Massimiliano; Thomas, David L; Fazekas, Franz; Tedeschi, Gioacchino; Barkhof, Frederik; Stefano, Nicola De; Filippi, Massimo
2015-07-01
In this multicenter study, we performed a tractography-based parcellation of the thalamus and its white matter connections to investigate the relationship between thalamic connectivity abnormalities and cognitive impairment in multiple sclerosis (MS). Dual-echo, morphological and diffusion tensor (DT) magnetic resonance imaging (MRI) scans were collected from 52 relapsing-remitting MS patients and 57 healthy controls from six European centers. Patients underwent an extensive neuropsychological assessment. Thalamic connectivity defined regions (CDRs) were segmented based on their cortical connectivity using diffusion tractography-based parcellation. Between-group differences of CDRs and cortico-thalamic tracts DT MRI indices were assessed. A vertex analysis of thalamic shape was also performed. A random forest analysis was run to identify the best imaging predictor of global cognitive impairment and deficits of specific cognitive domains. Twenty-two (43%) MS patients were cognitively impaired (CI). Compared to cognitively preserved, CI MS patients had increased fractional anisotropy of frontal, motor, postcentral and occipital connected CDRs (0.002
Breastfeeding During Infancy Is Associated With a Lower Future Risk of Pediatric Multiple Sclerosis.
Brenton, J Nicholas; Engel, Casey E; Sohn, Min-Woong; Goldman, Myla D
2017-12-01
Risk of multiple sclerosis (MS) is influenced by environment and genetics. Infant breastfeeding appears protective against some childhood autoimmune disorders, but its impact on risk of MS in childhood is unknown. The objective of this study is to analyze the association of breastfeeding in infancy on future risk of pediatric-onset MS. Biological mothers of 36 consecutive pediatric-onset MS patients completed a questionnaire on history of breastfeeding and various birth and demographic factors. The control group consisted of 72 otherwise healthy patients with a diagnosis of migraine and normal brain magnetic resonance imaging obtained less than 12 months before enrollment. Inverse probability of treatment weighting was used to reduce selection bias and balance the covariates between breastfed and non-breastfed children. Demographics (with the exception of body mass index) and birth factors were not significantly different between groups. Whereas 36% of cases were breastfed, 71% of controls were breastfed (P = 0.001). The median duration of breastfeeding was 0 weeks (range: 0 to 40 weeks) for cases and 16 weeks (range: 0 to 216 weeks) for controls. Lack of infant breastfeeding was associated with future diagnosis of pediatric-onset MS (odds ratio = 4.43; 95% confidence interval, 1.68 to 11.71; P = 0.003). This association remained significant after correcting for covariates, such as body mass index and age at diagnosis. These data demonstrate that absence of infant breastfeeding has an association with an increased risk of pediatric-onset MS diagnosis. Copyright © 2017 Elsevier Inc. All rights reserved.
Molecular field coefficients and cation distribution of substituted yttrium iron garnets
NASA Astrophysics Data System (ADS)
Röschmann, P.; Hansen, P.
1981-10-01
The saturation magnetization Ms(T) of Ga, Al, Sc, and CaVBi substituted Y3Fe5O12 (YIG) single crystals and of polycrystalline Ca/Ge and Ca/Ti substituted YIG has been investigated for 4.2 K ⩽T⩽TC. The samples were repeatedly annealed and quenched at different equilibrium temperatures 773 K⩽Te ⩽1523 K. The attained site exchange of Fe and the substituents between the a and d sites resulted in considerable changes of Ms(T). From a fit of the Néel molecular field theory to the Ms(T) data the dependence of the magnetic moments at T = 0 K and of the molecular field coefficients on the amount of nonmagnetic substitutions on the a and d sites were determined. It turned out that ion-specific sets of equations are required accounting for the ''particular ion effect'' of different cation species. The cation distributions inferred from the magnetic data have been analyzed along with a thermodynamic equilibrium model. The derived site stabilizing energies for the mixed Fe-Ga and Fe-Al garnets agree well with recently reported data. New results are presented for the site stabilizing energies in Ca/Ge:YIG and for the substituents Sc and Ti with octahedral site preference.
Auditory evoked magnetic fields to speech stimuli in newborns--effect of sleep stages.
Pihko, E; Sambeth, A; Leppänen, P H T; Okada, Y; Lauronen, L
2004-11-30
The aim of the study was to examine whether a newborn can detect changes in a speech stimulus consisting of a fricative followed by a vowel /su/. In addition, we studied possible effect of the two sleep stages (active and quiet sleep) on the evoked magnetic responses. In young children (6 years), the same stimulus evokes a prominent deflection, consisting of two peaks. The first one (P1m) is evoked by the beginning of the fricative consonant and has a latency of about 145 ms. The second peak (P2m) with a latency of 340 ms, is evoked by the switch to the vowel. In newborns (n = 10), the waveform resembled that of the older children but latencies of the corresponding peaks were longer, 190 and 435 ms, correspondingly. The results suggest that already the newborn brain detects the change inside the auditory speech stimulus, namely the fricative sound changing into a vowel. However, the immaturity of the brain is reflected in the prolonged latencies. In addition, the responses were higher in amplitude in quiet sleep than in active sleep (F (1.9) = 36.5; p < 0.0002). This is in line with the enhanced somatosensory magnetic fields to tactile stimulation in quiet compared to active sleep in newborns.
Golden, Nessa; Zhang, Chaosheng; Potito, Aaron P; Gibson, Paul J; Bargary, Norma; Morrison, Liam
2017-05-01
In recent decades, magnetic susceptibility monitoring has developed as a useful technique in environmental pollution studies, particularly metal contamination of soil. This study provides the first ever examination of the effects of grass cover on magnetic susceptibility (MS) measurements of underlying urban soils. Magnetic measurements were taken in situ to determine the effects on κ (volume magnetic susceptibility) when the grass layer was present (κ grass ) and after the grass layer was trimmed down to the root (κ no grass ). Height of grass was recorded in situ at each grid point. Soil samples (n=185) were collected and measurements of mass specific magnetic susceptibility (χ) were performed in the laboratory and frequency dependence (χ fd %) calculated. Metal concentrations (Pb, Cu, Zn and Fe) in the soil samples were determined and a gradiometry survey carried out in situ on a section of the study area. Significant correlations were found between each of the MS measurements and the metal content of the soil at the p<0.01 level. Spatial distribution maps were created using Inverse Distance Weighting (IDW) and Local Indicators of Spatial Association (LISA) to identify common patterns. κ grass (ranged from 1.67 to 301.00×10 -5 SI) and κ no grass (ranged from 2.08 to 530.67×10 -5 SI) measured in situ are highly correlated [r=0.966, n=194, p<0.01]. The volume susceptibility datasets in the presence and absence of grass coverage share a similar spatial distribution pattern. This study re-evaluates in situ κ monitoring techniques and the results suggest that the removal of grass coverage prior to obtaining in situ κ measurements of urban soil is unnecessary. This layer does not impede the MS sensor from accurately measuring elevated κ in soils, and therefore κ measurements recorded with grass coverage present can be reliably used to identify areas of urban soil metal contamination. Copyright © 2017 Elsevier Inc. All rights reserved.
Mosaic anisotropy model for magnetic interactions in mesostructured crystals
NASA Astrophysics Data System (ADS)
Goldman, Abby R.; Asenath-Smith, Emily; Estroff, Lara A.
2017-10-01
We propose a new model for interpreting the magnetic interactions in crystals with mosaic texture called the mosaic anisotropy (MA) model. We test the MA model using hematite as a model system, comparing mosaic crystals to polycrystals, single crystal nanoparticles, and bulk single crystals. Vibrating sample magnetometry confirms the hypothesis of the MA model that mosaic crystals have larger remanence (Mr/Ms) and coercivity (Hc) compared to polycrystalline or bulk single crystals. By exploring the magnetic properties of mesostructured crystalline materials, we may be able to develop new routes to engineering harder magnets.
Zhang, Ziheng; Dione, Donald P.; Brown, Peter B.; Shapiro, Erik M.; Sinusas, Albert J.; Sampath, Smita
2011-01-01
A novel MR imaging technique, spatial modulation of magnetization with polarity alternating velocity encoding (SPAMM-PAV), is presented to simultaneously examine the left ventricular early diastolic temporal relationships between myocardial deformation and intra-cavity hemodynamics with a high temporal resolution of 14 ms. This approach is initially evaluated in a dynamic flow and tissue mimicking phantom. A comparison of regional longitudinal strains and intra-cavity pressure differences (integration of computed in-plane pressure gradients within a selected region) in relation to mitral valve inflow velocities is performed in eight normal volunteers. Our results demonstrate that apical regions have higher strain rates (0.145 ± 0.005 %/ms) during the acceleration period of rapid filling compared to mid-ventricular (0.114 ± 0.007 %/ms) and basal regions (0.088 ± 0.009 %/ms), and apical strain curves plateau at peak mitral inflow velocity. This pattern is reversed during the deceleration period, when the strain-rates in the basal regions are the highest (0.027 ± 0.003 %/ms) due to ongoing basal stretching. A positive base-to-apex gradient in peak pressure difference is observed during acceleration, followed by a negative base-to apex gradient during deceleration. These studies shed insight into the regional volumetric and pressure difference changes in the left ventricle during early diastolic filling. PMID:21630348
Zwemmer, J N P; Berkhof, J; Castelijns, J A; Barkhof, F; Polman, C H; Uitdehaag, B M J
2006-10-01
Disease heterogeneity is a major issue in multiple sclerosis (MS). Classification of MS patients is usually based on clinical characteristics. More recently, a pathological classification has been presented. While clinical subtypes differ by magnetic resonance imaging (MRI) signature on a group level, a classification of individual MS patients based purely on MRI characteristics has not been presented so far. To investigate whether a restricted classification of MS patients can be made based on a combination of quantitative and qualitative MRI characteristics and to test whether the resulting subgroups are associated with clinical and laboratory characteristics. MRI examinations of the brain and spinal cord of 50 patients were scored for 21 quantitative and qualitative characteristics. Using latent class analysis, subgroups were identified, for whom disease characteristics and laboratory measures were compared. Latent class analysis revealed two subgroups that mainly differed in the extent of lesion confluency and MRI correlates of neuronal loss in the brain. Demographics and disease characteristics were comparable except for cognitive deficits. No correlations with laboratory measures were found. Latent class analysis offers a feasible approach for classifying subgroups of MS patients based on the presence of MRI characteristics. The reproducibility, longitudinal evolution and further clinical or prognostic relevance of the observed classification will have to be explored in a larger and independent sample of patients.
Lifting the veil on the dynamics of neuronal activities evoked by transcranial magnetic stimulation
Li, Bingshuo; Virtanen, Juha P; Oeltermann, Axel; Schwarz, Cornelius; Giese, Martin A; Ziemann, Ulf
2017-01-01
Transcranial magnetic stimulation (TMS) is a widely used non-invasive tool to study and modulate human brain functions. However, TMS-evoked activity of individual neurons has remained largely inaccessible due to the large TMS-induced electromagnetic fields. Here, we present a general method providing direct in vivo electrophysiological access to TMS-evoked neuronal activity 0.8–1 ms after TMS onset. We translated human single-pulse TMS to rodents and unveiled time-grained evoked activities of motor cortex layer V neurons that show high-frequency spiking within the first 6 ms depending on TMS-induced current orientation and a multiphasic spike-rhythm alternating between excitation and inhibition in the 6–300 ms epoch, all of which can be linked to various human TMS responses recorded at the level of spinal cord and muscles. The advance here facilitates a new level of insight into the TMS-brain interaction that is vital for developing this non-invasive tool to purposefully explore and effectively treat the human brain. PMID:29165241
Structural, electrical and magnetic properties of Sc3+ doped Mn-Zn ferrite nanoparticles
NASA Astrophysics Data System (ADS)
Angadi, V. Jagdeesha; Choudhury, Leema; Sadhana, K.; Liu, Hsiang-Lin; Sandhya, R.; Matteppanavar, Shidaling; Rudraswamy, B.; Pattar, Vinayak; Anavekar, R. V.; Praveena, K.
2017-02-01
Sc3+ doped Mn0.5Zn0.5ScyFe2-yO4 (y=0.00, 0.01, 0.03 and 0.05) nanoparticles were synthesized by solution combustion method using mixture of fuels were reported for the first time. The mixture of fuels plays an important role in obtaining nano crystalline, single phase present without any heat treatment. X-ray diffraction (XRD) results confirm the formation of the single-phase ferrites which crystallize in cubic spinel structure. The Fourier transform infrared spectra (FTIR) exhibit two prominent bands around 360 cm-1 and 540 cm-1 which are characteristic feature of spinel ferrite. The transmission electron microscope (TEM) micrographs revealed the nanoparticles to be nearly spherical in shape and of fairly uniform size. The room temperature impedance spectra (IS) and vibrating sample magnetometry (VSM) measurements were carried out in order to study the effect of doping (Sc3+) on the characteristic properties of Mn-Zn ferrites. Further, the frequency dependent dielectric constant and dielectric loss were found to decrease with increasing multiple Sc3+ concentration. Nyquist plot in the complex impedance spectra suggest the existence of multiple electrical responses. Magnetic measurements reveals that saturation magnetization (Ms), remnant magnetization (Mr), magnetic moment (ηB) and magnetic particle size (Dm) increase with Sc3+ ion concentration up to x=0.03 and then decrease. The values of spin canting angle (αY-K) and the magnetic particle size (Dm) are found to be in the range of 68-75° and 10-19 nm respectively with Sc3+ concentration. The room temperature Mössbauer spectra were fitted with two sextets corresponding to ions at tetrahedral (A-) and octahedral (B-) sites confirms the spinel lattice. The ferromagnetic resonance (FMR) spectra's has shown that high concentration of scandium doping leads to an increase in dipolar interaction and decrease in super exchange interaction.
Malla, Spundana; Kadimisetty, Karteek; Jiang, Di; Choudhary, Dharamainder; Rusling, James F
2018-05-11
Reactive metabolites of environmental chemicals and drugs can cause site-specific damage to p53 tumor suppressor gene in a major pathway for genotoxicity. We report here a high throughput, cell-free, 96-well plate magnetic bead-enzyme system interfaced with LC-MS/MS sequencing to bioactivate test chemicals and identify resulting adduction sites on genes. Bioactivated aflatoxin B1 was reacted with a 32 bp exon 7 fragment of the p53 gene using 8 microsomal cyt P450 enzymes from different organs coated on magnetic beads. All cyt P450s converted aflatoxin B1 to aflatoxin B1-8,9-epoxide that adducts guanine (G) in codon 249, with subsequent depurination to give abasic sites, then strand breaks. This is the first demonstration in a cell-free medium that aflatoxin B1 metabolite selectively causes abasic site formation and strand breaks at codon 249 of the p53 probe, corresponding to the chemical pathway and mutations of p53 in human liver cells and tumors. Molecular modeling supports the view that binding of aflatoxin B1-8,9-epoxide to G in codon 249 precedes the SN2 adduction reaction. Among a range of metabolic enzymes characteristic of different organs, human liver microsomes and cyt P450 3A5 supersomes showed the highest bioactivation rate for p53 exon 7 damage. This method to identify metabolite-related gene damage sites may facilitate predictions of organ-specific cancers for test chemicals via correlations with mutation sites.
A New In Vitro Co-Culture Model Using Magnetic Force-Based Nanotechnology.
Takanari, Hiroki; Miwa, Keiko; Fu, XianMing; Nakai, Junichi; Ito, Akira; Ino, Kousuke; Honda, Hiroyuki; Tonomura, Wataru; Konishi, Satoshi; Opthof, Tobias; van der Heyden, Marcel Ag; Kodama, Itsuo; Lee, Jong-Kook
2016-10-01
Skeletal myoblast (SkMB) transplantation has been conducted as a therapeutic strategy for severe heart failure. However, arrhythmogenicity following transplantation remains unsolved. We developed an in vitro model of myoblast transplantation with "patterned" or "randomly-mixed" co-culture of SkMBs and cardiomyocytes enabling subsequent electrophysiological, and arrhythmogenic evaluation. SkMBs were magnetically labeled with magnetite nanoparticles and co-cultured with neonatal rat ventricular myocytes (NRVMs) on multi-electrode arrays. SkMBs were patterned by a magnet beneath the arrays. Excitation synchronicity was evaluated by Ca(2+) imaging using a gene-encoded Ca(2+) indicator, G-CaMP2. In the monoculture of NRVMs (control), conduction was well-organized. In the randomly-mixed co-culture of NRVMs and SkMBs (random group), there was inhomogeneous conduction from multiple origins. In the "patterned" co-culture where an en bloc SKMB-layer was inserted into the NRVM-layer, excitation homogenously propagated although conduction was distorted by the SkMB-area. The 4-mm distance conduction time (CT) in the random group was significantly longer (197 ± 126 ms) than in control (17 ± 3 ms). In the patterned group, CT through NRVM-area did not change (25 ± 3 ms), although CT through the SkMB-area was significantly longer (132 ± 77 ms). The intervals between spontaneous excitation varied beat-to-beat in the random group, while regular beating was recorded in the control and patterned groups. Synchronized Ca(2+) transients of NRVMs were observed in the patterned group, whereas those in the random group were asynchronous. Patterned alignment of SkMBs is feasible with magnetic nanoparticles. Using the novel in vitro model mimicking cell transplantation, it may become possible to predict arrhythmogenicity due to heterogenous cell transplantation. J. Cell. Physiol. 231: 2249-2256, 2016. © 2016 Wiley Periodicals, Inc. © 2016 Wiley Periodicals, Inc.
Plasma membrane isolation using immobilized concanavalin A magnetic beads.
Lee, Yu-Chen; Srajer Gajdosik, Martina; Josic, Djuro; Lin, Sue-Hwa
2012-01-01
Isolation of highly purified plasma membranes is the key step in constructing the plasma membrane proteome. Traditional plasma membrane isolation method takes advantage of the differential density of organelles. While differential centrifugation methods are sufficient to enrich for plasma membranes, the procedure is lengthy and results in low recovery of the membrane fraction. Importantly, there is significant contamination of the plasma membranes with other organelles. The traditional agarose affinity matrix is suitable for isolating proteins but has limitation in separating organelles due to the density of agarose. Immobilization of affinity ligands to magnetic beads allows separation of affinity matrix from organelles through magnets and could be developed for the isolation of organelles. We have developed a simple method for isolating plasma membranes using lectin concanavalin A (ConA) magnetic beads. ConA is immobilized onto magnetic beads by binding biotinylated ConA to streptavidin magnetic beads. The ConA magnetic beads are used to bind glycosylated proteins present in the membranes. The bound membranes are solubilized from the magnetic beads with a detergent containing the competing sugar alpha methyl mannoside. In this study, we describe the procedure of isolating rat liver plasma membranes using sucrose density gradient centrifugation as described by Neville. We then further purify the membrane fraction by using ConA magnetic beads. After this purification step, main liver plasma membrane proteins, especially the highly glycosylated ones and proteins containing transmembrane domains could be identified by LC-ESI-MS/MS. While not described here, the magnetic bead method can also be used to isolate plasma membranes from cell lysates. This membrane purification method should expedite the cataloging of plasma membrane proteome.
Shoulder magnetic resonance imaging abnormalities, wheelchair propulsion, and gender.
Boninger, Michael L; Dicianno, Brad E; Cooper, Rory A; Towers, Jeffrey D; Koontz, Alicia M; Souza, Aaron L
2003-11-01
To investigate the relationship between pushrim forces and the progression of shoulder injuries in manual wheelchair users. Longitudinal case series. Biomechanics laboratory and magnetic resonance imaging (MRI) facility at a Veterans Health Administration medical center and university hospital, respectively. Fourteen individuals with spinal cord injury (8 men, 6 women) who used manual wheelchairs. Subjects propelled their own wheelchairs on a dynamometer at 0.9 and 1.8m/s. Bilateral biomechanical data were obtained by using force and moment sensing pushrims at time 1. Bilateral shoulder MR images were also completed on 2 occasions, at time 1 and, approximately 2 years later, at time 2. The peak pushrim forces in a pushrim coordinate system were calculated, weight normalized and averaged over 5 strokes (presented as % body weight). MRI abnormalities were graded by using a summated scale. Differences between scores between times 1 and 2 were calculated. Subjects were divided into 2 groups based on change in MRI score. Seven subjects were in the group with worsening scores (MRI+; mean, 8.14 points; range, 5-16), and 7 were in the group with improving or unchanging scores (MRI-; mean, -1.00 point; range, -5 to 1). There was no significant difference between groups with respect to age, body mass index, or years from injury. There were significantly more women in the MRI+ group (6 women, 1 man) than in the MRI- group (7 men) (P=.001). The MRI+ group used significantly greater weight-normalized radial force, or force directed toward the axle at time 1, to propel their wheelchairs at each speed (P<.01): MRI+ at 0.9m/s (mean radial force +/- standard deviation, 5.2%+/-1.0%) and MRI- at 0.9m/s (mean radial force, 3.2%+/-1.7%) (P=.028); and MRI+ at 1.8m/s (mean radial force, 6.6%+/-1.2%) (P=.023) and MRI- at 1.8m/s (mean radial force, 4.1%+/-2.2%). In a separate analysis, women were found to propel with a significantly higher radial force. A logistic regression found a significant relationship between radial force at time 1 and increased risk of progression of MRI findings over time. Individuals who propel with a greater percentage of force directed toward the axle were at increased risk of progression of MRI findings over time. Most people in this group were women. Clinicians should instruct wheelchair users in effective propulsion techniques and should pay particular attention to women who use wheelchairs. Reducing forces during wheelchair propulsion may minimize the likelihood of developing shoulder injuries.
Iron in Multiple Sclerosis and Its Noninvasive Imaging with Quantitative Susceptibility Mapping
Stüber, Carsten; Pitt, David; Wang, Yi
2016-01-01
Iron is considered to play a key role in the development and progression of Multiple Sclerosis (MS). In particular, iron that accumulates in myeloid cells after the blood-brain barrier (BBB) seals may contribute to chronic inflammation, oxidative stress and eventually neurodegeneration. Magnetic resonance imaging (MRI) is a well-established tool for the non-invasive study of MS. In recent years, an advanced MRI method, quantitative susceptibility mapping (QSM), has made it possible to study brain iron through in vivo imaging. Moreover, immunohistochemical investigations have helped defining the lesional and cellular distribution of iron in MS brain tissue. Imaging studies in MS patients and of brain tissue combined with histological studies have provided important insights into the role of iron in inflammation and neurodegeneration in MS. PMID:26784172
Pouponneau, Pierre; Leroux, Jean-Christophe; Soulez, Gilles; Gaboury, Louis; Martel, Sylvain
2011-05-01
Magnetic tumor targeting with external magnets is a promising method to increase the delivery of cytotoxic agents to tumor cells while reducing side effects. However, this approach suffers from intrinsic limitations, such as the inability to target areas within deep tissues, due mainly to a strong decrease of the magnetic field magnitude away from the magnets. Magnetic resonance navigation (MRN) involving the endovascular steering of therapeutic magnetic microcarriers (TMMC) represents a clinically viable alternative to reach deep tissues. MRN is achieved with an upgraded magnetic resonance imaging (MRI) scanner. In this proof-of-concept preclinical study, the preparation and steering of TMMC which were designed by taking into consideration the constraints of MRN and liver chemoembolization are reported. TMMC were biodegradable microparticles loaded with iron-cobalt nanoparticles and doxorubicin (DOX). These particles displayed high saturation magnetization (Ms = 72 emu g(-1)), MRI tracking compatibility (strong contrast on T2∗-weighted images), appropriate size for the blood vessel embolization (∼50 μm), and sustained release of DOX (over several days). The TMMC were successfully steered in vitro and in vivo in the rabbit model. In vivo targeting of the right or left liver lobes was achieved by MRN through the hepatic artery located 4 cm beneath the skin. Parameters such as flow velocity, TMMC release site in the artery, magnetic gradient and TMMC properties, affected the steering efficiency. These data illustrate the potential of MRN to improve drug targeting in deep tissues. Copyright © 2011 Elsevier Ltd. All rights reserved.
Phase relationships in the CeFe 8 Co 3 Ti 1 - y Si y system
DOE Office of Scientific and Technical Information (OSTI.GOV)
Conner, B. S.; McGuire, M. A.; Susner, M. A.
We investigated the phase formation behavior of the nominal CeFe 8Co 3Ti 1-ySi y system for 0 ≤ y ≤ 0.6 by powder x-ray diffraction and scanning electron microscopy with energy dispersive x-ray spectroscopy for ingots formed by arc-melting then annealing at 1000 °C and quenching to room temperature. The ingots are seen to nearly single phase for y ≤ 0.4 and are multi-phase for y ≥ 0.5 though a compound of the ThMn 12 type does indeed form for all values of y. We also measured the saturation magnetizations (M s), Curie temperatures (T C), and magnetic anisotropy fieldsmore » (H a) for the y ≤ 0.4 samples and the values of Ms and Ha appear to be nearly identical for all y 0.4. TC, but, is seen to increase about 20 °C in this range for increasing y.« less
Phase relationships in the CeFe 8 Co 3 Ti 1 - y Si y system
Conner, B. S.; McGuire, M. A.; Susner, M. A.; ...
2017-04-07
We investigated the phase formation behavior of the nominal CeFe 8Co 3Ti 1-ySi y system for 0 ≤ y ≤ 0.6 by powder x-ray diffraction and scanning electron microscopy with energy dispersive x-ray spectroscopy for ingots formed by arc-melting then annealing at 1000 °C and quenching to room temperature. The ingots are seen to nearly single phase for y ≤ 0.4 and are multi-phase for y ≥ 0.5 though a compound of the ThMn 12 type does indeed form for all values of y. We also measured the saturation magnetizations (M s), Curie temperatures (T C), and magnetic anisotropy fieldsmore » (H a) for the y ≤ 0.4 samples and the values of Ms and Ha appear to be nearly identical for all y 0.4. TC, but, is seen to increase about 20 °C in this range for increasing y.« less
Raz, Eytan; Branson, Brittany; Jensen, Jens H.; Bester, Maxim; Babb, James S.; Herbert, Joseph; Grossman, Robert I.; Inglese, Matilde
2015-01-01
PURPOSE Despite the increasing development and applications of iron imaging, the pathophysiology of iron accumulation in multiple sclerosis (MS), and its role in disease progression and development of clinical disability, is poorly understood. The aims of our study were to determine the presence and extent of iron in T2 visible lesions and gray and white matter using magnetic field correlation (MFC) MRI and correlate with microscopic white matter (WM) injury as measured by diffusion tensor imaging (DTI). MATERIALS AND METHODS This is a case-control study incuding a series of 31 patients with clinically definite MS. The mean age was 39 years [standard deviation (SD)=9.55], they were 11 males and 20 females, with a disease duration average of 3 years (range 0-13) and a median EDSS of 2 (0-4.5). Seventeen healthy volunteers (6 males and 11 females) with a mean age of 36 years (SD=11.4) were recruited. All subjects underwent MR imaging on a 3T scanner using T2-weighted sequence, 3D T1 MPRAGE, MFC, single-shot DTI and postcontrast T1. T2-lesion volumes, brain volumetry, DTI parameters and iron quantification were calculated and multiple correlations were exploited. RESULTS Increased MFC was found in the putamen (p=0.061), the thalamus (p=0.123), the centrum semiovale (p=0.053), globus pallidus (p=0.008) and gray matter (GM) (p=0.004) of MS patients compared to controls. The mean lesional MFC was 121 s−2 (SD=67), significantly lower compared to the GM MFC (<0.0001). The GM mean diffusivity (MD) was inversely correlated with the MFC in the centrum semiovale (p<0.001), and in the splenium of the corpus callosum (p<0.001). CONCLUSION Patients with MS have increased iron in the globus pallidus, putamen and centrum with a trend toward increased iron in all the brain structures. Quantitative iron evaluation of WM and GM may improve the understanding of MS pathophysiology, and might serve as a surrogate marker of disease progression. PMID:25416468
Tandonnet, Christophe; Davranche, Karen; Meynier, Chloé; Burle, Borís; Vidal, Franck; Hasbroucq, Thierry
2012-02-01
We investigated the influence of temporal preparation on information processing. Single-pulse transcranial magnetic stimulation (TMS) of the primary motor cortex was delivered during a between-hand choice task. The time interval between the warning and the imperative stimulus varied across blocks of trials was either optimal (500 ms) or nonoptimal (2500 ms) for participants' performance. Silent period duration was shorter prior to the first evidence of response selection for the optimal condition. Amplitude of the motor evoked potential specific to the responding hand increased earlier for the optimal condition. These results revealed an early release of cortical inhibition and a faster integration of the response selection-related inputs to the corticospinal pathway when temporal preparation is better. Temporal preparation may induce cortical activation prior to response selection that speeds up the implementation of the selected response. Copyright © 2011 Society for Psychophysiological Research.
Wave Driven Non-linear Flow Oscillator for the 22-Year Solar Cycle
NASA Technical Reports Server (NTRS)
Mayr, Hans G.; Wolff, Charles L.; Hartle, Richard E.; Einaudi, Franco (Technical Monitor)
2000-01-01
In the Earth's atmosphere, a zonal flow oscillation is observed with periods between 20 and 32 months, the Quasi Biennial Oscillation. This oscillation does not require external time dependent forcing but is maintained by non-linear wave momentum deposition. It is proposed that such a mechanism also drives long-period oscillations in planetary and stellar interiors. We apply this mechanism to generate a flow oscillation for the 22-year solar cycle. The oscillation would occur just below the convective envelope where waves can propagate. Using scale analysis, we present results from a simplified model that incorporates Hines' gravity wave parameterization. Wave amplitudes less than 10 m/s can produce reversing zonal flows of 25 m/s that should be sufficient to generate a corresponding oscillation in the poloidal magnetic field. Low buoyancy frequency and the associated increase in turbulence help to produce the desired oscillation period of the flow.
Multiple sclerosis - etiology and diagnostic potential.
Kamińska, Joanna; Koper, Olga M; Piechal, Kinga; Kemona, Halina
2017-06-30
Multiple sclerosis (MS) is a chronic inflammatory and demyelinating disease of autoimmune originate. The main agents responsible for the MS development include exogenous, environmental, and genetic factors. MS is characterized by multifocal and temporally scattered central nervous system (CNS) damage which lead to the axonal damage. Among clinical courses of MS it can be distinguish relapsing-remitting multiple sclerosis (RRMS), secondary progressive multiple sclerosis (SPSM), primary progressive multiple sclerosis (PPMS), and progressive-relapsing multiple sclerosis (RPMS). Depending on the severity of signs and symptoms MS can be described as benign MS or malignant MS. MS diagnosis is based on McDonald's diagnostic criteria, which link clinical manifestation with characteristic lesions demonstrated by magnetic resonance imaging (MRI), cerebrospinal fluid (CSF) analysis, and visual evoked potentials. Among CSF laboratory tests used to the MS diagnosis are applied: Tibbling & Link IgG index, reinbegrams, and CSF isoelectrofocusing for oligoclonal bands detection. It should be emphasized, that despite huge progress regarding MS as well as the availability of different diagnostics methods this disease is still a diagnostic challenge. It may result from fact that MS has diverse clinical course and there is a lack of single test, which would be of appropriate diagnostic sensitivity and specificity for quick and accurate diagnosis.
Sundararajan, M; Kennedy, L John; Vijaya, J Judith
2015-09-01
Pure and cobalt doped zinc ferrites were prepared by microwave combustion method using L-arginine as a fuel. The prepared samples were characterized by various instrumental techniques such as X-ray powder diffractometry, high resolution scanning electron microscopy (HR-SEM), energy dispersive X-ray analysis, Fourier transformed infrared (FT-IR) spectroscopy, photoluminescence spectroscopy and UV-Visible diffuse reflectance spectroscopy. Vibrating sample magnetometry at room temperature was recorded to study the magnetic behavior of the samples. X-ray analysis confirmed the formation of zinc ferrites normal spinel-type structure with an average crystallite sizes in the range, 25.69 nm to 35.68 nm. The lattice parameters decreased as cobalt fraction was increased. The HR-SEM images showed nanoparticles are agglomerated. The estimated band gap energy value was found to decrease with an increase in cobalt content (1.87 to 1.62 eV). Broad visible emissions are observed in the photoluminescence spectra. A gradual increase in the coercivity and saturation magnetization (M(s)) were noted at relatively higher cobalt doping fractions.
NASA Astrophysics Data System (ADS)
Ramakrishna, K. S.; Srinivas, Ch.; Tirupanyam, B. V.; Ramesh, P. N.; Meena, S. S.; Potukuchi, D. M.; Sastry, D. L.
2017-05-01
Spinel ferrite nanoparticles with chemical equation NixCu0.1Zn0.9-xFe2O4 (x = 0.5, 0.6, 0.7) have been synthsized using co-precipitation method followed by heat treatment at a temperature of 200 °C for 2h. The results of XRD, FE-SEM and VSM studies are reported. XRD patterns confirm the formation of cubic spinel phase of ferrite samples along with small amount of a secondary phase of α-Fe2O3 whose concentration decreases as Ni2+ concentration increases. The crystallite sizes (in the range of 7.5-13.9 nm) increase and the lattice parameter decreases with increase in Ni2+ ion concentration. These values are comparable to those of NiZn ferrite without Cu substitution. It has been observed that there is a considerable reduction in saturation magnetisation (Ms). This and differences in other magnetic parameters are attributed to considerable changes in cation distribution or core shell interactions of NiZn ferrite with 10 mole% Cu substitution in the place of Zn.
Influence of Iron Doping on Structural, Optical and Magnetic Properties of TiO2 Nanoparticles
NASA Astrophysics Data System (ADS)
Zahid, R.; Manzoor, M.; Rafiq, A.; Ikram, M.; Nafees, M.; Butt, A. R.; Hussain, S. G.; Ali, S.
2018-05-01
In this study, various concentrations of Fe doped TiO2 nanoparticles have been successfully synthesized using the sol-gel method. A variety of characterization techniques as ultra-violet visible (UV-Vis) spectroscopy, X-ray diffractometer (XRD), vibrating sample magnetometry (VSM) and field emission scanning electron microscopy (FESEM) were employed to analyze the prepared nanopowders. XRD measurement confirmed the substitution of Fe ion without disturbing the tetragonal crystal system of TiO2. The crystallite size was found to decrease and lattice strain increases upon doping estimated by Williamson Hall plot. Furthermore, the average grain size calculated by FESEM found was between 10 and 30 nm for pure and doped TiO2. UV-Vis spectroscopy showed an increase in absorption accompanied red shift and increase in band gap energies from 3.36 to 3.62 eV with the addition of Fe. The FTIR spectroscopy was employed to confirm the presence of functional groups in the fabricated nanopowders. Upon mixing the saturation magnetization (Ms) varying from (2.12 to 1.51)10-2 emu/g was observed.
Is 3D MPRAGE better than the combination DIR/PSIR for cortical lesion detection at 3T MRI?
Nelson, Flavia; Poonawalla, Aziz; Datta, Sushmita; Wolinsky, Jerry; Narayana, Ponnada
2014-03-01
Based on the application of newer magnetic resonance imaging (MRI) acquisition sequences, the detection of cortical lesions (CL) in multiple sclerosis (MS) has significantly improved. Double inversion recovery (DIR) at 3T has increased the detection sensitivity and classification specificity when combined with phase sensitive inversion recovery (PSIR). Previous findings with 3D magnetization prepared rapid acquisition with gradient echo (MPRAGE) sequences, showed improved classification specificity of purely intracortical (IC) and mixed (MX) lesions, compared to the classification based on DIR/PSIR. Direct comparison between the detection of CL by 3D MPRAGE and by DIR/PSIR at 3T has not been evaluated. Eleven subjects were imaged on a 3T magnet. DIR/PSIR and 3D MPRAGE images were reviewed independently. Each image set was reviewed twice; only lesions detected on both sessions were scored. Review time per scan was ~5min for DIR/PSIR and ~15min for 3D MPRAGE. We identified 141 CL (62 IC+79 MX) based on DIR/PSIR images vs. 93 (38 IC+55 MX) based on MPRAGE from all eleven patients. MPRAGE under-detected the number of CL in seven cases and over-detected the number of CL in three, only one case had the same number of CL on both sets of images. Combination DIR/PSIR at 3T is superior to 3D MPRAGE for detection of cortical gray matter lesions in MS. The contrast-to-noise ratio of CL appears to be inferior on the MPRAGE images relative to DIR/PSIR. © 2013 Published by Elsevier B.V.
MFL Benchmark Problem 2: Laboratory Measurements
NASA Astrophysics Data System (ADS)
Etcheverry, J.; Pignotti, A.; Sánchez, G.; Stickar, P.
2003-03-01
This experiment involves the measurement of the magnetic flux leaked from a rotating seamless steel tube with two machined notches. The signal measured is the radial component of the leaked field at a fixed point in space, as a function of the notch position, for four values of the liftoff and two notches. As the pipe tangential velocity was varied between 0.23 and 0.62 m/s, the sole observed effect was that of increasing the signal by a value that grows linearly with the velocity and is independent of the notch angular position.
Relating Brain Damage to Brain Plasticity in Patients With Multiple Sclerosis
Tomassini, Valentina; Johansen-Berg, Heidi; Jbabdi, Saad; Wise, Richard G.; Pozzilli, Carlo; Palace, Jacqueline; Matthews, Paul M.
2013-01-01
Background Failure of adaptive plasticity with increasing pathology is suggested to contribute to progression of disability in multiple sclerosis (MS). However, functional impairments can be reduced with practice, suggesting that brain plasticity is preserved even in patients with substantial damage. Objective Here, functional magnetic resonance imaging (fMRI) was used to probe systems-level mechanisms of brain plasticity associated with improvements in visuomotor performance in MS patients and related to measures of microstructural damage. Methods 23 MS patients and 12 healthy controls underwent brain fMRI during the first practice session of a visuomotor task (short-term practice) and after 2 weeks of daily practice with the same task (longer-term practice). Participants also underwent a structural brain MRI scan. Results Patients performed more poorly than controls at baseline. Nonetheless, with practice, patients showed performance improvements similar to controls and independent of the extent of MRI measures of brain pathology. Different relationships between performance improvements and activations were found between groups: greater short-term improvements were associated with lower activation in the sensorimotor, posterior cingulate, and parahippocampal cortices for patients, whereas greater long-term improvements correlated with smaller activation reductions in the visual cortex of controls. Conclusions Brain plasticity for visuomotor practice is preserved in MS patients despite a high burden of cerebral pathology. Cognitive systems different from those acting in controls contribute to this plasticity in patients. These findings challenge the notion that increasing pathology is accompanied by an outright failure of adaptive plasticity, supporting a neuroscientific rationale for recovery-oriented strategies even in chronically disabled patients. PMID:22328685
Patel, Dhavalkumar Narendrabhai; Li, Lin; Kee, Chee-Leong; Ge, Xiaowei; Low, Min-Yong; Koh, Hwee-Ling
2014-01-01
The popularity of phosphodiesterase type 5 (PDE-5) enzyme inhibitors for the treatment of erectile dysfunction has led to the increase in prevalence of illicit sexual performance enhancement products. PDE-5 inhibitors, namely sildenafil, tadalafil and vardenafil, and their unapproved designer analogues are being increasingly used as adulterants in the herbal products and health supplements marketed for sexual performance enhancement. To date, more than 50 unapproved analogues of prescription PDE-5 inhibitors were found as adulterants in the literature. To avoid detection of such adulteration by standard screening protocols, the perpetrators of such illegal products are investing time and resources to synthesize exotic analogues and devise novel means for adulteration. A comprehensive review of conventional and advance analytical techniques to detect and characterize the adulterants is presented. The rapid identification and structural elucidation of unknown analogues as adulterants is greatly enhanced by the wide myriad of analytical techniques employed, including high performance liquid chromatography (HPLC), gas chromatography-mass spectrometry (GC-MS), liquid chromatography mass-spectrometry (LC-MS), nuclear magnetic resonance (NMR) spectroscopy, vibrational spectroscopy, liquid chromatography-Fourier transform ion cyclotron resonance-mass spectrometry (LC-FT-ICR-MS), liquid chromatograph-hybrid triple quadrupole linear ion trap mass spectrometer with information dependent acquisition, ultra high performance liquid chromatography-time of flight-mass spectrometry (UHPLC-TOF-MS), ion mobility spectroscopy (IMS) and immunoassay methods. The many challenges in detecting and characterizing such adulterants, and the need for concerted effort to curb adulteration in order to safe guard public safety and interest are discussed. Copyright © 2013 Elsevier B.V. All rights reserved.
Sandvig, Inger; Barlinn, Jon; Nedregaard, Bård; Skjeldal, Ola H
2015-03-01
Multiple sclerosis (MS) has traditionally been considered a disease of adults. However, in recent years, there have been numerous reports about the disease occurring in childhood and adolescence. The purpose of this article is to document Norwegian experience of this population based on clinical observations and neuroradiological findings. Children and adolescents diagnosed with MS at the Department of Child Neurology, Oslo University Hospital, between 1 January 2004 and 1 May 2012 were included. Gender, previous diseases, age, symptoms at first attack, spinal fluid findings and cerebral magnetic resonance tomography (MRI) findings were recorded. The course of the disease, treatment and sequelae was noted. The study includes 18 patients who received MS diagnosis. Median age at onset was 10 years and six months. The presenting symptoms and MRI findings varied. Almost all patients were treated with steroids in the acute phase and later with interferon-beta. Some patients were treated with natalizumab when there was lack of efficiency of interferon-beta. Seven patients developed permanent, moderate sequelae in terms of motor, sensory, or cerebellar symptoms. Nine patients had cognitive difficulties and 11 specified increased fatigability. MS in children and adolescents is a disease with varying acute neurological symptoms and findings. The patients were treated with the same medicines as adults with MS and tolerated it well. We found that cognitive sequelae and fatigue were common also in this young age group. Copyright © 2014 European Paediatric Neurology Society. Published by Elsevier Ltd. All rights reserved.
In vivo chlorine and sodium MRI of rat brain at 21.1 T
Elumalai, Malathy; Kitchen, Jason A.; Qian, Chunqi; Gor’kov, Peter L.; Brey, William W.
2017-01-01
Object MR imaging of low-gamma nuclei at the ultrahigh magnetic field of 21.1 T provides a new opportunity for understanding a variety of biological processes. Among these, chlorine and sodium are attracting attention for their involvement in brain function and cancer development. Materials and methods MRI of 35Cl and 23Na were performed and relaxation times were measured in vivo in normal rat (n = 3) and in rat with glioma (n = 3) at 21.1 T. The concentrations of both nuclei were evaluated using the center-out back-projection method. Results T1 relaxation curve of chlorine in normal rat head was fitted by bi-exponential function (T1a = 4.8 ms (0.7) T1b = 24.4 ± 7 ms (0.3) and compared with sodium (T1 = 41.4 ms). Free induction decays (FID) of chlorine and sodium in vivo were bi-exponential with similar rapidly decaying components of T2a∗=0.4 ms and T2a∗=0.53 ms, respectively. Effects of small acquisition matrix and bi-exponential FIDs were assessed for quantification of chlorine (33.2 mM) and sodium (44.4 mM) in rat brain. Conclusion The study modeled a dramatic effect of the bi-exponential decay on MRI results. The revealed increased chlorine concentration in glioma (~1.5 times) relative to a normal brain correlates with the hypothesis asserting the importance of chlorine for tumor progression. PMID:23748497
Iron-related gene variants and brain iron in multiple sclerosis and healthy individuals.
Hagemeier, Jesper; Ramanathan, Murali; Schweser, Ferdinand; Dwyer, Michael G; Lin, Fuchun; Bergsland, Niels; Weinstock-Guttman, Bianca; Zivadinov, Robert
2018-01-01
Brain iron homeostasis is known to be disturbed in multiple sclerosis (MS), yet little is known about the association of common gene variants linked to iron regulation and pathological tissue changes in the brain. In this study, we investigated the association of genetic determinants linked to iron regulation with deep gray matter (GM) magnetic susceptibility in both healthy controls (HC) and MS patients. Four hundred (400) patients with MS and 150 age- and sex-matched HCs were enrolled and obtained 3 T MRI examination. Three (3) single nucleotide polymorphisms (SNPs) associated with iron regulation were genotyped: two SNPs in the human hereditary hemochromatosis protein gene HFE : rs1800562 (C282Y mutation) and rs1799945 (H63D mutation), as well as the rs1049296 SNP in the transferrin gene (C2 mutation). The effects of disease and genetic status were studied using quantitative susceptibility mapping (QSM) voxel-based analysis (VBA) and region-of-interest (ROI) analysis of the deep GM. The general linear model framework was used to compare groups. Analyses were corrected for age and sex, and adjusted for false discovery rate. We found moderate increases in susceptibility in the right putamen of participants with the C282Y (+ 6.1 ppb) and H63D (+ 6.9 ppb) gene variants vs. non-carriers, as well as a decrease in thalamic susceptibility of progressive MS patients with the C282Y mutation (left: - 5.3 ppb, right: - 6.7 ppb, p < 0.05). Female MS patients had lower susceptibility in the caudate (- 6.0 ppb) and putamen (left: - 3.9 ppb, right: - 4.6 ppb) than men, but only when they had a wild-type allele (p < 0.05). Iron-gene linked increases in putamen susceptibility (in HC and relapsing remitting MS) and decreases in thalamus susceptibility (in progressive MS), coupled with apparent sex interactions, indicate that brain iron in healthy and disease states may be influenced by genetic factors.
Magnetic Moment of Proton Drip-Line Nucleus (9)C
NASA Technical Reports Server (NTRS)
Matsuta, K.; Fukuda, M.; Tanigaki, M.; Minamisono, T.; Nojiri, Y.; Mihara, M.; Onishi, T.; Yamaguchi, T.; Harada, A.; Sasaki, M.
1994-01-01
The magnetic moment of the proton drip-line nucleus C-9(I(sup (pi)) = 3/2, T(sub 1/2) = 126 ms) has been measured for the first time, using the beta-NMR detection technique with polarized radioactive beams. The measure value for the magnetic moment is 1mu(C-9)! = 1.3914 +/- 0.0005 (mu)N. The deduced spin expectation value
Ion behavior in low-power magnetically shielded and unshielded Hall thrusters
NASA Astrophysics Data System (ADS)
Grimaud, L.; Mazouffre, S.
2017-05-01
Magnetically shielded Hall thrusters achieve a longer lifespan than traditional Hall thrusters by reducing wall erosion. The lower erosion rate is attributed to a reduction of the high energy ion population impacting the walls. To investigate this phenomenon, the ion velocity distribution functions are measured with laser induced fluorescence at several points of interest in the magnetically shielded ISCT200-MS and the unshielded ISCT200-US Hall thrusters. The center of the discharge channel is probed to highlight the difference in plasma positioning between the shielded and unshielded thrusters. Erosion phenomena are investigated by taking measurements of the ion velocity distribution near the inner and outer wall as well as above the magnetic poles where some erosion is observed. The resulting distribution functions show a displacement of the acceleration region from inside the channel in the unshielded thruster to downstream of the exit plane in the ISCT200-MS. Near the walls, the unshielded thruster displays both a higher relative ion density as well as a significant fraction of the ions with velocities toward the walls compared to the shielded thruster. Higher proportions of high velocity ions are also observed. Those results are in accordance with the reduced erosion observed. Both shielded and unshielded thrusters have large populations of ions impacting the magnetic poles. The mechanism through which those ions are accelerated toward the magnetic poles has so far not been explained.
Magnetic fields driven by tidal mixing in radiative stars
NASA Astrophysics Data System (ADS)
Vidal, Jérémie; Cébron, David; Schaeffer, Nathanaël; Hollerbach, Rainer
2018-04-01
Stellar magnetism plays an important role in stellar evolution theory. Approximatively 10 per cent of observed main sequence (MS) and pre-main-sequence (PMS) radiative stars exhibit surface magnetic fields above the detection limit, raising the question of their origin. These stars host outer radiative envelopes, which are stably stratified. Therefore, they are assumed to be motionless in standard models of stellar structure and evolution. We focus on rapidly rotating, radiative stars which may be prone to the tidal instability, due to an orbital companion. Using direct numerical simulations in a sphere, we study the interplay between a stable stratification and the tidal instability, and assess its dynamo capability. We show that the tidal instability is triggered regardless of the strength of the stratification (Brunt-Väisälä frequency). Furthermore, the tidal instability can lead to both mixing and self-induced magnetic fields in stably stratified layers (provided that the Brunt-Väisälä frequency does not exceed the stellar spin rate in the simulations too much). The application to stars suggests that the resulting magnetic fields could be observable at the stellar surfaces. Indeed, we expect magnetic field strengths up to several Gauss. Consequently, tidally driven dynamos should be considered as a (complementary) dynamo mechanism, possibly operating in radiative MS and PMS stars hosting orbital companions. In particular, tidally driven dynamos may explain the observed magnetism of tidally deformed and rapidly rotating Vega-like stars.
Magnetic Hysteresis of Deep-Sea Sediments in Korea Deep Ocean Study(KODOS) Area, NE Pacific
NASA Astrophysics Data System (ADS)
Kim, K.; Park, C.; Yoo, C.
2001-12-01
The KODOS area within the Clarion-Clipperton fracture zone (C-C zone) is surrounded by the Hawaiian and Line Island Ridges to the west and the central American continent to the east. Topography of the seafloor consists of flat-topped abyssal hills and adjacent abyssal troughs, both of which run parallel in N-S direction. Sediments from the study area consist mainly of biogenic sediments. Latitudinal zonation of sedimentary facies was caused by the accumulation of biogenic materials associated with the equatorial current system and movement of the Pacific plate toward the north or northwest. The KODOS area belongs to the latitudinal transition zone having depositional characteristics between non-fossiliferous pelagic clay-dominated zone and calcareous sediment-dominated zone. The box core sediments of the KODOS area are analyzed in an attempt to obtain magnetic hysteresis information and to elucidate the relationship between hysteresis property and lithological facies. Variations in magnetic hysteresis parameters with unit layers reflect the magnetic grain-size and concentrations within the sediments. The ratios of remanant coercivity/coercive force (Hcr/Hc) and saturation remnance/saturation magnetization (Mrs/Ms) indicate that coarse magnetic grains are mainly distributed in dark brown sediments (lower part of the sediment core samples) reflecting high Hcr/Hc and low Mrs/Ms ratios. These results are mainly caused by dissolution differences with core depth. From the plotting of the ratios of hyteresis parameters, it is indicated that magnetic minerals in cubic samples are in pseudo-single domain (PSD) state.
Optimal design of a vibration-based energy harvester using magnetostrictive material (MsM)
NASA Astrophysics Data System (ADS)
Hu, J.; Xu, F.; Huang, A. Q.; Yuan, F. G.
2011-01-01
In this study, an optimal vibration-based energy harvesting system using magnetostrictive material (MsM) was designed and tested to enable the powering of a wireless sensor. In particular, the conversion efficiency, converting from magnetic to electric energy, is approximately modeled from the magnetic field induced by the beam vibration. A number of factors that affect the output power such as the number of MsM layers, coil design and load matching are analyzed and explored in the design optimization. From the measurements, the open-circuit voltage can reach 1.5 V when the MsM cantilever beam operates at the second natural frequency 324 Hz. The AC output power is 970 µW, giving a power density of 279 µW cm - 3. The attempt to use electrical reactive components (either inductors or capacitors) to resonate the system at any frequency has also been analyzed and tested experimentally. The results showed that this approach is not feasible to optimize the power. Since the MsM device has low output voltage characteristics, a full-wave quadrupler has been designed to boost the rectified output voltage. To deliver the maximum output power to the load, a complex conjugate impedance matching between the load and the MsM device is implemented using a discontinuous conduction mode (DCM) buck-boost converter. The DC output power after the voltage quadrupler reaches 705 µW and the corresponding power density is 202 µW cm - 3. The output power delivered to a lithium rechargeable battery is around 630 µW, independent of the load resistance.
Rouvière, Olivier; Souchon, Rémi; Pagnoux, Gaële; Ménager, Jean-Michel; Chapelon, Jean-Yves
2011-10-01
To evaluate the feasibility and reproducibility of renal magnetic resonance elastography (MRE) in young healthy volunteers. Ten volunteers underwent renal MRE twice at a 4-5 week interval. The vibrations (45 and 76 Hz) were generated by a speaker positioned beneath the volunteers' back and centered on their left kidney. For each frequency, three sagittal slices were acquired (eight phase offsets per cycle, motion-encoding gradients successively positioned along the three directions of space). Shear velocity images were reconstructed using the curl operator combined with the local frequency estimation (LFE) algorithm. The mean shear velocities measured in the renal parenchyma during the two examinations were not significantly different and exhibited a mean variation of 6% at 45 Hz and 76 Hz. The mean shear velocities in renal parenchyma were 2.21 ± 0.14 m/s at 45 Hz (shear modulus of 4.9 ± 0.5 kPa) and 3.07 ± 0.17 m/s at 76 Hz (9.4 ± 0.8 kPa, P < 0.01). The mean shear velocities in the renal cortex and medulla were respectively 2.19 ± 0.13 m/s and 2.32 ± 0.16 m/s at 45 Hz (P = 0.002) and 3.06 ± 0.16 m/s and 3.10 ± 0.22 m/s at 76 Hz (P = 0.13). Renal MRE was feasible and reproducible. Two independent measurements of shear velocities in the renal parenchyma of the same subjects showed an average variability of 6%. Copyright © 2011 Wiley-Liss, Inc.
Permanent magnetic properties of NdFe12Nx sputtered films epitaxially grown on V buffer layer
NASA Astrophysics Data System (ADS)
Sato, T.; Ohsuna, T.; Yano, M.; Kato, A.; Kaneko, Y.
2017-08-01
To clarify the magnetic properties of the NdFe12Nx compound, which shows promise as a high-performance permanent magnet material, NdFe12Nx epitaxial films fabricated by using a V underlayer on MgO (100) single-crystalline substrates were investigated. Nd-Fe films deposited on a V underlayer consist of NdFe12 grains, which have a c-axis orientation perpendicular to the film plane, as well as α-Fe and Nd2Fe17 phases. In the Nd-Fe-N film obtained by subsequent nitridation of the Nd-Fe film, NdFe12Nx grains grew as the dominant phase, and the volume fractions of α-Fe phases dropped below 5%. A Nd-Fe-N film with a thickness of 50 nm exhibits a saturation magnetization (Ms) of 1.7 T, an anisotropy field (HA) of ˜60 kOe, a magnetocrystalline anisotropy energy (K1) of ˜4.1 MJ/m3, and a coercivity (Hc) of 1.7 kOe. The Hc of a Nd-Fe-N film with a thickness of 25 nm is 4.3 kOe. These results indicate that NdFe12Nx compounds have a superior Ms compared to Nd-Fe-B magnets, while the enhancement in Hc is indispensable.
Jia, Yuqian; Su, Hao; Wong, Y-L Elaine; Chen, Xiangfeng; Dominic Chan, T-W
2016-07-22
In this work, the thermo-responsive polymer PNIPAM tethered to Fe3O4@SiO2@MOF core-shell magnetic microspheres was first synthesized by a surface-selective post-synthetic strategy and underwent highly efficient magnetic solid-phase extraction (MSPE) of alkylphenols from aqueous samples. Alkylphenols, including 4-tert-octylphenol (OP) and 4-n-nonylphenol (NP), were selected as target compounds. The sample quantification was carried out using LC-MS/MS in multiple reaction monitor (MRM) mode. Under optimal working conditions, the developed method showed good linearity in the range of 5-1000ngL(-1), a low limit of detection (1.5ngL(-1)), and good repeatability (relative standard deviation, <8%, n=5) for NP and OP. Owning to the hydrophilic/hydrophobic switchable properties of the nanocomposite, high recoveries (78.7-104.3%) of alkylphenols were obtained under different extraction conditions. The levels of OP and NP in environmental samples collected from local river, lake and pond waters were analyzed using the developed method. It was believed that the synthesized material with the thermo-responsive coating, large surface areas and magnetic properties should have great potential in the extraction and removal of alkylphenols from environmental samples. Copyright © 2016 Elsevier B.V. All rights reserved.
Heinen, Klaartje; Jolij, Jacob; Lamme, Victor A F
2005-09-08
Discriminating objects from their surroundings by the visual system is known as figure-ground segregation. This process entails two different subprocesses: boundary detection and subsequent surface segregation or 'filling in'. In this study, we used transcranial magnetic stimulation to test the hypothesis that temporally distinct processes in V1 and related early visual areas such as V2 or V3 are causally related to the process of figure-ground segregation. Our results indicate that correct discrimination between two visual stimuli, which relies on figure-ground segregation, requires two separate periods of information processing in the early visual cortex: one around 130-160 ms and the other around 250-280 ms.
Mid-Miocene C4 expansion on the Chinese Loess Plateau under an enhanced Asian summer monsoon
NASA Astrophysics Data System (ADS)
Dong, Jibao; Liu, Zhonghui; An, Zhisheng; Liu, Weiguo; Zhou, Weijian; Qiang, Xiaoke; Lu, Fengyan
2018-06-01
Atmospheric CO2 starvation, aridity, fire and warm season precipitation have all been proposed as major contributors to C4 plant expansion during the Late Miocene. However, the driving factors responsible for the distribution of C4 plants in the early and mid-Miocene still remain enigmatic. Here we report pedogenic carbon and oxygen isotope data (δ13Cpedo, δ18Opedo), along with magnetic susceptibility (MS) results, from the Zhuang Lang drilling core on the Chinese Loess Plateau (CLP). Elevated δ13Cpedo values (>-5‰) signal a prominent C4 expansion and substantially increased δ18Opedo and MS values indicate enhanced Asian summer monsoon (ASM) precipitation. Both of these conditions are observed during the Mid-Miocene Climatic Optimum (MMCO), 14.5-17 million years ago. The marked increase in C4 plants, associated with warm temperatures and increased precipitation, strongly suggests the control of an enhanced ASM on C4 expansion on the CLP during the MMCO. This finding contrasts with the late-Miocene C4 expansion associated with cooling and drying conditions observed in low latitudes and argues for regionally specific control of C4 plant distribution/expansion.
Excitation of small-scale waves in the F region of the ionosphere by powerful HF radio waves
NASA Astrophysics Data System (ADS)
Blagoveshchenskaya, N. F.; Chernyshev, M. Y.; Kornienko, V. A.
1998-01-01
Ionospheric small-scale waves in the F region, initiated by heating facilities in Nizhniy Novgorod, have been studied by the method of field-aligned scattering of diagnostic HF radio signals. Experimental data have been obtained on the radio path Kiev-N. Novgorod-St. Petersburg during heating campaigns with heater radiated power ERP = 20 MW and 100 MW. Observations of scattered HF signals have been made by a Doppler spectrum device with high temporal resolution. Analysis of the experimental data shows a relation between the heater power level and the parameters of ionospheric small-scale oscillations falling within the range of Pc 3-4 magnetic pulsations. It is found that the periods of wave processes in the F region of the ionosphere, induced by the heating facility, decrease with increasing heating power. The level of heating power also has an impact on the horizontal east-west component of the electric field E, the vertical component of the Doppler velocity Vd and the amplitude of the vertical displacements M of the heated region. Typical magnitudes of these parameters are the following: E = 1.25 mVm, Vd = 6 ms, M = 600-1500 m for ERP = 20 MW and E = 2.5-4.5 mVm, Vd = 11-25 ms, M = 1000-5000 m for ERP = 100 MW. The results obtained confirm the hypothesis of excitation of the Alfvén resonator by powerful HF radio waves which leads to the generation of magnetic field oscillations in the heated region giving rise to artificial Pc 3-4 magnetic pulsations and ionospheric small-scale wave processes. In this situation an increase of the heater power would lead to a growth of the electric field of hydromagnetic waves propagating in the ionosphere as well as the amplitude of the vertical displacements of the heated region.
Sun, He; Xu, Meng-Tao; Wang, Xiao-Qi; Wang, Meng-Hu; Wang, Bao-Heng; Wang, Feng-Zhe; Pan, Shi-Nong
2018-05-05
Magnetic resonance (MR) imaging provides a unique, noninvasive diagnostic platform to quantify the physiological and biochemical variables of skeletal muscle at rest. This study was to investigate the difference in thigh skeletal muscles between snowboarding halfpipe athletes and healthy volunteers via multiparametric MR imaging. A comparative study was conducted between 12 healthy volunteers and 14 snowboarding halfpipe athletes. MR scanning targeted the left leg at the level of the proximal thigh on a 3.0T MR system. The measured parameters compared between the two groups included T1, T2, T2* relaxation times, fat fraction (FF), and cross-sectional area (CSA) of the quadriceps femoris and the hamstring muscles. Statistical analysis was carried out using independent sample t-test. Interrater reliability was also assessed with intraclass correlation coefficients (ICCs). It was statistically equivalent between two groups in age, body mass index, thigh circumference, calf circumference, systolic blood pressure, and resting heart rate (all P > 0.05). However, the T1 and T2 values of the hamstring muscles in the athlete group were found to be significantly shorter than those in control group (T1: 1063.3 ± 24.1 ms vs. 1112.0 ± 38.2 ms in biceps femoris, 1050.4 ± 31.2 ms vs. 1095.0 ± 39.5 ms in semitendinosus, 1053.1 ± 31.7 ms vs. 1118.4 ± 40.0 ms in semimembranosus, respectively; T2: 33.4 ± 0.7 ms vs. 36.1 ± 1.9 ms in biceps femoris, 34.6 ± 2.0 ms vs. 37.0 ± 1.9 ms in semitendinosus, 36.9 ± 1.5 ms vs. 38.9 ± 2.4 ms in semimembranosus, respectively; all P < 0.05) although T2* relaxation time was detected with no significant difference. The FF of the hamstring muscles was obviously less than the control group (5.5 ± 1.9% vs. 10.7 ± 4.7%, P < 0.001). In addition, the quadriceps' CSA in the athlete group was substantially larger than the control group (8039.0 ± 1072.3 vs. 6258.2 ± 852.0 mm 2 , P < 0.001). Interrater reliability was excellent (ICC: 0.758-0.994). Multiple MR imaging parameters indicated significant differences between snowboarding halfpipe athletes and healthy volunteers in the thigh skeletal muscles.
Mang, Cameron S.; Snow, Nicholas J.; Campbell, Kristin L.; Ross, Colin J. D.
2014-01-01
The objectives of the present study were to evaluate the impact of a single bout of high-intensity aerobic exercise on 1) long-term potentiation (LTP)-like neuroplasticity via response to paired associative stimulation (PAS) and 2) the temporal and spatial components of sequence-specific implicit motor learning. Additionally, relationships between exercise-induced increases in systemic brain-derived neurotrophic factor (BDNF) and response to PAS and motor learning were evaluated. Sixteen young healthy participants completed six experimental sessions, including the following: 1) rest followed by PAS; 2) aerobic exercise followed by PAS; 3) rest followed by practice of a continuous tracking (CT) task and 4) a no-exercise 24-h retention test; and 5) aerobic exercise followed by CT task practice and 6) a no-exercise 24-h retention test. The CT task included an embedded repeated sequence allowing for evaluation of sequence-specific implicit learning. Slope of motor-evoked potential recruitment curves generated with transcranial magnetic stimulation showed larger increases when PAS was preceded by aerobic exercise (59.8% increase) compared with rest (14.2% increase, P = 0.02). Time lag of CT task performance on the repeated sequence improved under the aerobic exercise condition from early (−100.8 ms) to late practice (−75.2 ms, P < 0.001) and was maintained at retention (−79.2 ms, P = 0.004) but did not change under the rest condition (P > 0.16). Systemic BDNF increased on average by 3.4-fold following aerobic exercise (P = 0.003), but the changes did not relate to neurophysiological or behavioral measures (P > 0.42). These results indicate that a single bout of high-intensity aerobic exercise can prime LTP-like neuroplasticity and promote sequence-specific implicit motor learning. PMID:25257866