Sample records for making high precision

  1. VIEW OF MICROMACHINING, HIGH PRECISION EQUIPMENT USED TO CUSTOM MAKE ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    VIEW OF MICRO-MACHINING, HIGH PRECISION EQUIPMENT USED TO CUSTOM MAKE SMALL PARTS. LUMPS OF CLAY; SHOWN IN THE PHOTOGRAPH, WERE USED TO STABILIZE PARTS BEING MACHINED. (11/1/87) - Rocky Flats Plant, Stainless Steel & Non-Nuclear Components Manufacturing, Southeast corner of intersection of Cottonwood & Third Avenues, Golden, Jefferson County, CO

  2. Precision Health Economics and Outcomes Research to Support Precision Medicine: Big Data Meets Patient Heterogeneity on the Road to Value.

    PubMed

    Chen, Yixi; Guzauskas, Gregory F; Gu, Chengming; Wang, Bruce C M; Furnback, Wesley E; Xie, Guotong; Dong, Peng; Garrison, Louis P

    2016-11-02

    The "big data" era represents an exciting opportunity to utilize powerful new sources of information to reduce clinical and health economic uncertainty on an individual patient level. In turn, health economic outcomes research (HEOR) practices will need to evolve to accommodate individual patient-level HEOR analyses. We propose the concept of "precision HEOR", which utilizes a combination of costs and outcomes derived from big data to inform healthcare decision-making that is tailored to highly specific patient clusters or individuals. To explore this concept, we discuss the current and future roles of HEOR in health sector decision-making, big data and predictive analytics, and several key HEOR contexts in which big data and predictive analytics might transform traditional HEOR into precision HEOR. The guidance document addresses issues related to the transition from traditional to precision HEOR practices, the evaluation of patient similarity analysis and its appropriateness for precision HEOR analysis, and future challenges to precision HEOR adoption. Precision HEOR should make precision medicine more realizable by aiding and adapting healthcare resource allocation. The combined hopes for precision medicine and precision HEOR are that individual patients receive the best possible medical care while overall healthcare costs remain manageable or become more cost-efficient.

  3. Precision Health Economics and Outcomes Research to Support Precision Medicine: Big Data Meets Patient Heterogeneity on the Road to Value

    PubMed Central

    Chen, Yixi; Guzauskas, Gregory F.; Gu, Chengming; Wang, Bruce C. M.; Furnback, Wesley E.; Xie, Guotong; Dong, Peng; Garrison, Louis P.

    2016-01-01

    The “big data” era represents an exciting opportunity to utilize powerful new sources of information to reduce clinical and health economic uncertainty on an individual patient level. In turn, health economic outcomes research (HEOR) practices will need to evolve to accommodate individual patient–level HEOR analyses. We propose the concept of “precision HEOR”, which utilizes a combination of costs and outcomes derived from big data to inform healthcare decision-making that is tailored to highly specific patient clusters or individuals. To explore this concept, we discuss the current and future roles of HEOR in health sector decision-making, big data and predictive analytics, and several key HEOR contexts in which big data and predictive analytics might transform traditional HEOR into precision HEOR. The guidance document addresses issues related to the transition from traditional to precision HEOR practices, the evaluation of patient similarity analysis and its appropriateness for precision HEOR analysis, and future challenges to precision HEOR adoption. Precision HEOR should make precision medicine more realizable by aiding and adapting healthcare resource allocation. The combined hopes for precision medicine and precision HEOR are that individual patients receive the best possible medical care while overall healthcare costs remain manageable or become more cost-efficient. PMID:27827859

  4. Precision mechatronics based on high-precision measuring and positioning systems and machines

    NASA Astrophysics Data System (ADS)

    Jäger, Gerd; Manske, Eberhard; Hausotte, Tino; Mastylo, Rostyslav; Dorozhovets, Natalja; Hofmann, Norbert

    2007-06-01

    Precision mechatronics is defined in the paper as the science and engineering of a new generation of high precision systems and machines. Nanomeasuring and nanopositioning engineering represents important fields of precision mechatronics. The nanometrology is described as the today's limit of the precision engineering. The problem, how to design nanopositioning machines with uncertainties as small as possible will be discussed. The integration of several optical and tactile nanoprobes makes the 3D-nanopositioning machine suitable for various tasks, such as long range scanning probe microscopy, mask and wafer inspection, nanotribology, nanoindentation, free form surface measurement as well as measurement of microoptics, precision molds, microgears, ring gauges and small holes.

  5. Study on high-precision measurement of long radius of curvature

    NASA Astrophysics Data System (ADS)

    Wu, Dongcheng; Peng, Shijun; Gao, Songtao

    2016-09-01

    It is hard to get high-precision measurement of the radius of curvature (ROC), because of many factors that affect the measurement accuracy. For the measurement of long radius of curvature, some factors take more important position than others'. So, at first this paper makes some research about which factor is related to the long measurement distance, and also analyse the uncertain of the measurement accuracy. At second this article also study the influence about the support status and the adjust error about the cat's eye and confocal position. At last, a 1055micrometer radius of curvature convex is measured in high-precision laboratory. Experimental results show that the proper steady support (three-point support) can guarantee the high-precision measurement of radius of curvature. Through calibrating the gain of cat's eye and confocal position, is useful to ensure the precise position in order to increase the measurement accuracy. After finish all the above process, the high-precision long ROC measurement is realized.

  6. Position measurement of the direct drive motor of Large Aperture Telescope

    NASA Astrophysics Data System (ADS)

    Li, Ying; Wang, Daxing

    2010-07-01

    Along with the development of space and astronomy science, production of large aperture telescope and super large aperture telescope will definitely become the trend. It's one of methods to solve precise drive of large aperture telescope using direct drive technology unified designed of electricity and magnetism structure. A direct drive precise rotary table with diameter of 2.5 meters researched and produced by us is a typical mechanical & electrical integration design. This paper mainly introduces position measurement control system of direct drive motor. In design of this motor, position measurement control system requires having high resolution, and precisely aligning the position of rotor shaft and making measurement, meanwhile transferring position information to position reversing information corresponding to needed motor pole number. This system has chosen high precision metal band coder and absolute type coder, processing information of coders, and has sent 32-bit RISC CPU making software processing, and gained high resolution composite coder. The paper gives relevant laboratory test results at the end, indicating the position measurement can apply to large aperture telescope control system. This project is subsidized by Chinese National Natural Science Funds (10833004).

  7. Development and Validation of High Precision Thermal, Mechanical, and Optical Models for the Space Interferometry Mission

    NASA Technical Reports Server (NTRS)

    Lindensmith, Chris A.; Briggs, H. Clark; Beregovski, Yuri; Feria, V. Alfonso; Goullioud, Renaud; Gursel, Yekta; Hahn, Inseob; Kinsella, Gary; Orzewalla, Matthew; Phillips, Charles

    2006-01-01

    SIM Planetquest (SIM) is a large optical interferometer for making microarcsecond measurements of the positions of stars, and to detect Earth-sized planets around nearby stars. To achieve this precision, SIM requires stability of optical components to tens of picometers per hour. The combination of SIM s large size (9 meter baseline) and the high stability requirement makes it difficult and costly to measure all aspects of system performance on the ground. To reduce risks, costs and to allow for a design with fewer intermediate testing stages, the SIM project is developing an integrated thermal, mechanical and optical modeling process that will allow predictions of the system performance to be made at the required high precision. This modeling process uses commercial, off-the-shelf tools and has been validated against experimental results at the precision of the SIM performance requirements. This paper presents the description of the model development, some of the models, and their validation in the Thermo-Opto-Mechanical (TOM3) testbed which includes full scale brassboard optical components and the metrology to test them at the SIM performance requirement levels.

  8. The Geoscience Laser Altimetry/Ranging System (GLARS)

    NASA Technical Reports Server (NTRS)

    Cohen, S. C.; Degnan, J. J.; Bufton, J. L.; Garvin, J. B.; Abshire, J. B.

    1986-01-01

    The Geoscience Laser Altimetry Ranging System (GLARS) is a highly precise distance measurement system to be used for making extremely accurate geodetic observations from a space platform. It combines the attributes of a pointable laser ranging system making observations to cube corner retroreflectors placed on the ground with those of a nadir looking laser altimeter making height observations to ground, ice sheet, and oceanic surfaces. In the ranging mode, centimeter-level precise baseline and station coordinate determinations will be made on grids consisting of 100 to 200 targets separated by distances from a few tens of kilometers to about 1000 km. These measurements will be used for studies of seismic zone crustal deformations and tectonic plate motions. Ranging measurements will also be made to a coarser, but globally distributed array of retroreflectors for both precise geodetic and orbit determination applications. In the altimetric mode, relative height determinations will be obtained with approximately decimeter vertical precision and 70 to 100 meter horizontal resolution. The height data will be used to study surface topography and roughness, ice sheet and lava flow thickness, and ocean dynamics. Waveform digitization will provide a measure of the vertical extent of topography within each footprint. The planned Earth Observing System is an attractive candidate platform for GLARS since the GLAR data can be used both for direct analyses and for highly precise orbit determination needed in the reduction of data from other sensors on the multi-instrument platform. (1064, 532, and 355 nm)Nd:YAG laser meets the performance specifications for the system.

  9. Classification of LIDAR Data for Generating a High-Precision Roadway Map

    NASA Astrophysics Data System (ADS)

    Jeong, J.; Lee, I.

    2016-06-01

    Generating of a highly precise map grows up with development of autonomous driving vehicles. The highly precise map includes a precision of centimetres level unlike an existing commercial map with the precision of meters level. It is important to understand road environments and make a decision for autonomous driving since a robust localization is one of the critical challenges for the autonomous driving car. The one of source data is from a Lidar because it provides highly dense point cloud data with three dimensional position, intensities and ranges from the sensor to target. In this paper, we focus on how to segment point cloud data from a Lidar on a vehicle and classify objects on the road for the highly precise map. In particular, we propose the combination with a feature descriptor and a classification algorithm in machine learning. Objects can be distinguish by geometrical features based on a surface normal of each point. To achieve correct classification using limited point cloud data sets, a Support Vector Machine algorithm in machine learning are used. Final step is to evaluate accuracies of obtained results by comparing them to reference data The results show sufficient accuracy and it will be utilized to generate a highly precise road map.

  10. Molecularly precise dendrimer-drug conjugates with tunable drug release for cancer therapy.

    PubMed

    Zhou, Zhuxian; Ma, Xinpeng; Murphy, Caitlin J; Jin, Erlei; Sun, Qihang; Shen, Youqing; Van Kirk, Edward A; Murdoch, William J

    2014-10-06

    The structural preciseness of dendrimers makes them perfect drug delivery carriers, particularly in the form of dendrimer-drug conjugates. Current dendrimer-drug conjugates are synthesized by anchoring drug and functional moieties onto the dendrimer peripheral surface. However, functional groups exhibiting the same reactivity make it impossible to precisely control the number and the position of the functional groups and drug molecules anchored to the dendrimer surface. This structural heterogeneity causes variable pharmacokinetics, preventing such conjugates to be translational. Furthermore, the highly hydrophobic drug molecules anchored on the dendrimer periphery can interact with blood components and alter the pharmacokinetic behavior. To address these problems, we herein report molecularly precise dendrimer-drug conjugates with drug moieties buried inside the dendrimers. Surprisingly, the drug release rates of these conjugates were tailorable by the dendrimer generation, surface chemistry, and acidity. © 2014 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  11. Precision manufacturing for clinical-quality regenerative medicines.

    PubMed

    Williams, David J; Thomas, Robert J; Hourd, Paul C; Chandra, Amit; Ratcliffe, Elizabeth; Liu, Yang; Rayment, Erin A; Archer, J Richard

    2012-08-28

    Innovations in engineering applied to healthcare make a significant difference to people's lives. Market growth is guaranteed by demographics. Regulation and requirements for good manufacturing practice-extreme levels of repeatability and reliability-demand high-precision process and measurement solutions. Emerging technologies using living biological materials add complexity. This paper presents some results of work demonstrating the precision automated manufacture of living materials, particularly the expansion of populations of human stem cells for therapeutic use as regenerative medicines. The paper also describes quality engineering techniques for precision process design and improvement, and identifies the requirements for manufacturing technology and measurement systems evolution for such therapies.

  12. Topics in inference and decision-making with partial knowledge

    NASA Technical Reports Server (NTRS)

    Safavian, S. Rasoul; Landgrebe, David

    1990-01-01

    Two essential elements needed in the process of inference and decision-making are prior probabilities and likelihood functions. When both of these components are known accurately and precisely, the Bayesian approach provides a consistent and coherent solution to the problems of inference and decision-making. In many situations, however, either one or both of the above components may not be known, or at least may not be known precisely. This problem of partial knowledge about prior probabilities and likelihood functions is addressed. There are at least two ways to cope with this lack of precise knowledge: robust methods, and interval-valued methods. First, ways of modeling imprecision and indeterminacies in prior probabilities and likelihood functions are examined; then how imprecision in the above components carries over to the posterior probabilities is examined. Finally, the problem of decision making with imprecise posterior probabilities and the consequences of such actions are addressed. Application areas where the above problems may occur are in statistical pattern recognition problems, for example, the problem of classification of high-dimensional multispectral remote sensing image data.

  13. High precision measurement of the proton charge radius: The PRad experiment

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Meziane, Mehdi

    2013-11-01

    The recent high precision measurements of the proton charge radius performed at PSI from muonic hydrogen Lamb shift puzzled the hadronic physics community. A value of 0.8418 {+-} 0.0007 fm was extracted which is 7{sigma} smaller than the previous determinations obtained from electron-proton scattering experiments and based on precision spectroscopy of electronic hydrogen. An additional extraction of the proton charge radius from electron scattering at Mainz is also in good agreement with these "electronic" determinations. An independent measurement of the proton charge radius from unpolarized elastic ep scattering using a magnetic spectrometer free method was proposed and fully approved atmore » Jefferson Laboratory in June 2012. This novel technique uses the high precision calorimeter HyCal and a windowless hydrogen gas target which makes possible the extraction of the charge radius at very forward angles and thus very low momentum transfer Q{sup 2} up to 10{sup -4} (GeV/c){sup 2} with an unprecedented sub-percent precision for this type of experiment. In this paper, after a review of the recent progress on the proton charge radius extraction and the new high precision experiment PRad will be presented.« less

  14. SmallSat Precision Navigation with Low-Cost MEMS IMU Swarms

    NASA Technical Reports Server (NTRS)

    Christian, John; Bishop, Robert; Martinez, Andres; Petro, Andrew

    2015-01-01

    The continued advancement of small satellite-based science missions requires the solution to a number of important technical challenges. Of particular note is that small satellite missions are characterized by tight constraints on cost, mass, power, and volume that make them unable to fly the high-quality Inertial Measurement Units (IMUs) required for orbital missions demanding precise orientation and positioning. Instead, small satellite missions typically fly low-cost Micro-Electro-Mechanical System (MEMS) IMUs. Unfortunately, the performance characteristics of these MEMS IMUs make them ineffectual in many spaceflight applications when employed in a single IMU system configuration.

  15. PRECISE ANGLE MONITOR BASED ON THE CONCEPT OF PENCIL-BEAM INTERFEROMETRY

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    QIAN,S.; TAKACS,P.

    2000-07-30

    The precise angle monitoring is a very important metrology task for research, development and industrial applications. Autocollimator is one of the most powerful and widely applied instruments for small angle monitoring, which is based on the principle of geometric optics. In this paper the authors introduce a new precise angle monitoring system, Pencil-beam Angle Monitor (PAM), base on pencil beam interferometry. Its principle of operation is a combination of physical and geometrical optics. The angle calculation method is similar to the autocollimator. However, the autocollimator creates a cross image but the precise pencil-beam angle monitoring system produces an interference fringemore » on the focal plane. The advantages of the PAM are: high angular sensitivity, long-term stability character making angle monitoring over long time periods possible, high measurement accuracy in the order of sub-microradian, simultaneous measurement ability in two perpendicular directions or on two different objects, dynamic measurement possibility, insensitive to the vibration and air turbulence, automatic display, storage and analysis by use of the computer, small beam diameter making the alignment extremely easy and longer test distance. Some test examples are presented.« less

  16. Effects of Boron and Graphite Uncertainty in Fuel for TREAT Simulations

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Vaughn, Kyle; Mausolff, Zander; Gonzalez, Esteban

    Advanced modeling techniques and current computational capacity make full core TREAT simulations possible, with the goal of such simulations to understand the pre-test core and minimize the number of required calibrations. But, in order to simulate TREAT with a high degree of precision the reactor materials and geometry must also be modeled with a high degree of precision. This paper examines how uncertainty in the reported values of boron and graphite have an effect on simulations of TREAT.

  17. Simple Refractometers for Index Measurements by Minimum Deviation Method from Far-ultraviolet to Near Infrared

    NASA Technical Reports Server (NTRS)

    Leviton, Douglas B.; Madison, Timothy J.; Petrone, Peter

    1998-01-01

    The focal shift of an optical filter used in non-collimated light depends directly on substrate thickness and index of refraction. The HST Advanced Camera for Surveys (ACS) requires a set of filters whose focal shifts are tightly matched. Knowing the index of refraction for substrate glasses allows precise substrate thicknesses to be specified. Two refractometers have been developed at the Goddard Space Flight Center (GSFC) to determine the indices of refraction of materials from which ACS filters are made. Modem imaging detectors for the near infrared, visible, and far ultraviolet spectral regions make these simple yet sophisticated refractometers possible. A new technology, high accuracy, angular encoder also developed at GSFC makes high precision index measurement possible in the vacuum ultraviolet.

  18. High-Precision Coupling Mechanism Operable By Robots

    NASA Technical Reports Server (NTRS)

    Voellmer, George

    1992-01-01

    Coupling mechanism has features making it easily operable by hand and suitable for operation by robots: tolerates some initial misalignment, imposes precise final alignment, and protects itself against overtightening. Typically used to mount equipment module on structure. Mechanism includes kinematic mounts, which tolerate small initial misalignment and enforce precise final alignment as two assemblies brought together. Clamping force applied to kinematic mounts via two flexible plates. Bolt and nut tightened on flexible plates to impose spring clamping load. Repeatability of interface tested and found to be better than forty-millionths of inch.

  19. Beyond Precision: Issues of Morality and Decision Making in Minimizing Collateral Casualties

    DTIC Science & Technology

    2003-04-28

    possible contributions from moral judgment and decision making . As Fuller himself said, laws “can create the conditions essential for a rational ...BEYOND PRECISION: Issues of Morality and Decision Making in Minimizing Collateral Casualties Program in Arms Control, Disarmament, and...28 APR 2003 2. REPORT TYPE N/A 3. DATES COVERED - 4. TITLE AND SUBTITLE Beyond Precision: Issues of Morality and Decision Making in

  20. Improved Slip Casting Of Ceramic Models

    NASA Technical Reports Server (NTRS)

    Buck, Gregory M.; Vasquez, Peter; Hicks, Lana P.

    1994-01-01

    Improved technique of investment slip casting developed for making precise ceramic wind-tunnel models. Needed in wind-tunnel experiments to verify predictions of aerothermodynamical computer codes. Ceramic materials used because of their low heat conductivities and ability to survive high temperatures. Present improved slip-casting technique enables casting of highly detailed models from aqueous or nonaqueous solutions. Wet shell molds peeled off models to ensure precise and undamaged details. Used at NASA Langley Research Center to form superconducting ceramic components from nonaqueous slip solutions. Technique has many more applications when ceramic materials developed further for such high-strength/ temperature components as engine parts.

  1. High-Resolution Spectroscopy at the Wyoming Infrared Observatory: Setting TESS Science on FHiRE

    NASA Astrophysics Data System (ADS)

    Jang-Condell, Hannah; Pierce, Michael J.; Pilachowski, C. A.; Kobulnicky, Henry; McLane, Jacob N.

    2018-01-01

    The Fiber High Resolution Echelle (FHiRE) spectrograph is a new instrument designed for the 2.3-m Wyoming InfraRed Observatory (WIRO). With the construction of a vacuum chamber for FHiRE to stabilize the spectrograph and a temperature-stabilized Thorium-Argon lamp for precise velocity calibration, we will be able to achieve 1 m/s RV precision, making it an ideal instrument for finding exoplanets. Details of the design of FHiRE are presented in a companion poster (Pierce et al.). The construction of this instrument is well-timed with the planned 2018 launch of NASA's Transiting Exoplanet Survey Satellite (TESS) mission. TESS will require a great deal of follow-up spectroscopy to characterize potential exoplanet host stars as well as radial velocity measurements to confirm new exoplanets. WIRO is ideally suited to acquire the long-term, high-cadence observations that will be required to make progress in this frontier area of astrophysics. We will coordinate our efforts with the TESS Follow-up Observing Program (TFOP), specifically as part of the Recon Spectroscopy and Precise Radial Velocity Work sub-groups.This work is supported by a grant from NASA EPSCOR.

  2. Citation searches are more sensitive than keyword searches to identify studies using specific measurement instruments.

    PubMed

    Linder, Suzanne K; Kamath, Geetanjali R; Pratt, Gregory F; Saraykar, Smita S; Volk, Robert J

    2015-04-01

    To compare the effectiveness of two search methods in identifying studies that used the Control Preferences Scale (CPS), a health care decision-making instrument commonly used in clinical settings. We searched the literature using two methods: (1) keyword searching using variations of "Control Preferences Scale" and (2) cited reference searching using two seminal CPS publications. We searched three bibliographic databases [PubMed, Scopus, and Web of Science (WOS)] and one full-text database (Google Scholar). We report precision and sensitivity as measures of effectiveness. Keyword searches in bibliographic databases yielded high average precision (90%) but low average sensitivity (16%). PubMed was the most precise, followed closely by Scopus and WOS. The Google Scholar keyword search had low precision (54%) but provided the highest sensitivity (70%). Cited reference searches in all databases yielded moderate sensitivity (45-54%), but precision ranged from 35% to 75% with Scopus being the most precise. Cited reference searches were more sensitive than keyword searches, making it a more comprehensive strategy to identify all studies that use a particular instrument. Keyword searches provide a quick way of finding some but not all relevant articles. Goals, time, and resources should dictate the combination of which methods and databases are used. Copyright © 2015 Elsevier Inc. All rights reserved.

  3. Citation searches are more sensitive than keyword searches to identify studies using specific measurement instruments

    PubMed Central

    Linder, Suzanne K.; Kamath, Geetanjali R.; Pratt, Gregory F.; Saraykar, Smita S.; Volk, Robert J.

    2015-01-01

    Objective To compare the effectiveness of two search methods in identifying studies that used the Control Preferences Scale (CPS), a healthcare decision-making instrument commonly used in clinical settings. Study Design & Setting We searched the literature using two methods: 1) keyword searching using variations of “control preferences scale” and 2) cited reference searching using two seminal CPS publications. We searched three bibliographic databases [PubMed, Scopus, Web of Science (WOS)] and one full-text database (Google Scholar). We report precision and sensitivity as measures of effectiveness. Results Keyword searches in bibliographic databases yielded high average precision (90%), but low average sensitivity (16%). PubMed was the most precise, followed closely by Scopus and WOS. The Google Scholar keyword search had low precision (54%) but provided the highest sensitivity (70%). Cited reference searches in all databases yielded moderate sensitivity (45–54%), but precision ranged from 35–75% with Scopus being the most precise. Conclusion Cited reference searches were more sensitive than keyword searches, making it a more comprehensive strategy to identify all studies that use a particular instrument. Keyword searches provide a quick way of finding some but not all relevant articles. Goals, time and resources should dictate the combination of which methods and databases are used. PMID:25554521

  4. The prospects of pulsar timing with new-generation radio telescopes and the Square Kilometre Array

    NASA Astrophysics Data System (ADS)

    Stappers, B. W.; Keane, E. F.; Kramer, M.; Possenti, A.; Stairs, I. H.

    2018-05-01

    Pulsars are highly magnetized and rapidly rotating neutron stars. As they spin, the lighthouse-like beam of radio emission from their magnetic poles sweeps across the Earth with a regularity approaching that of the most precise clocks known. This precision combined with the extreme environments in which they are found, often in compact orbits with other neutron stars and white dwarfs, makes them excellent tools for studying gravity. Present and near-future pulsar surveys, especially those using the new generation of telescopes, will find more extreme binary systems and pulsars that are more precise `clocks'. These telescopes will also greatly improve the precision to which we can measure the arrival times of the pulses. The Square Kilometre Array will revolutionize pulsar searches and timing precision. The increased number of sources will reveal rare sources, including possibly a pulsar-black hole binary, which can provide the most stringent tests of strong-field gravity. The improved timing precision will reveal new phenomena and also allow us to make a detection of gravitational waves in the nanohertz frequency regime. It is here where we expect to see the signature of the binary black holes that are formed as galaxies merge throughout cosmological history. This article is part of a discussion meeting issue `The promises of gravitational-wave astronomy'.

  5. Ultra-High Precision Half-Life Measurement for the Superallowed &+circ; Emitter ^26Al^m

    NASA Astrophysics Data System (ADS)

    Finlay, P.; Demand, G.; Garrett, P. E.; Leach, K. G.; Phillips, A. A.; Sumithrarachchi, C. S.; Svensson, C. E.; Triambak, S.; Grinyer, G. F.; Leslie, J. R.; Andreoiu, C.; Cross, D.; Austin, R. A. E.; Ball, G. C.; Bandyopadhyay, D.; Djongolov, M.; Ettenauer, S.; Hackman, G.; Pearson, C. J.; Williams, S. J.

    2009-10-01

    The calculated nuclear structure dependent correction for ^26Al^m (δC-δNS= 0.305(27)% [1]) is smaller by nearly a factor of two than the other twelve precision superallowed cases, making it an ideal case to pursue a reduction in the experimental errors contributing to the Ft value. An ultra-high precision half-life measurement for the superallowed &+circ; emitter ^26Al^m has been made at the Isotope Separator and Accelerator (ISAC) facility at TRIUMF in Vancouver, Canada. A beam of ˜10^5 ^26Al^m/s was delivered in October 2007 and its decay was observed using a 4π continuous gas flow proportional counter as part of an ongoing experimental program in superallowed Fermi β decay studies. With a statistical precision of ˜0.008%, the present work represents the single most precise measurement of any superallowed half-life to date. [4pt] [1] I.S. Towner and J.C. Hardy, Phys. Rev. C 79, 055502 (2009).

  6. Ultra-High Precision Half-Life Measurement for the Superallowed &+circ; Emitter ^26Al^m

    NASA Astrophysics Data System (ADS)

    Finlay, P.; Demand, G.; Garrett, P. E.; Leach, K. G.; Phillips, A. A.; Sumithrarachchi, C. S.; Svensson, C. E.; Triambak, S.; Ball, G. C.; Bandyopadhyay, D.; Djongolov, M.; Ettenauer, S.; Hackman, G.; Pearson, C. J.; Williams, S. J.; Andreoiu, C.; Cross, D.; Austin, R. A. E.; Grinyer, G. F.; Leslie, J. R.

    2008-10-01

    The calculated nuclear structure dependent correction for ^26Al^m (δC-δNS= 0.305(27)% [1]) is smaller by nearly a factor of two than the other twelve precision superallowed cases, making it an ideal case to pursue a reduction in the experimental errors contributing to the Ft value. An ultra-high precision half-life measurement for the superallowed &+circ; emitter ^26Al^m has been made using a 4π continuous gas flow proportional counter as part of an ongoing experimental program in superallowed Fermi β decay studies at the Isotope Separator and Accelerator (ISAC) facility at TRIUMF in Vancouver, Canada, which delivered a beam of ˜10^5 ^26Al^m/s in October 2007. With a statistical precision of ˜0.008%, the present work represents the single most precise measurement of any superallowed half-life to date. [1] I.S. Towner and J.C. Hardy, Phys. Rev. C 77, 025501 (2008).

  7. Turbulence Measurements from Compliant Moorings. Part II: Motion Correction

    DOE PAGES

    Kilcher, Levi F.; Thomson, Jim; Harding, Samuel; ...

    2017-06-20

    Acoustic Doppler velocimeters (ADVs) are a valuable tool for making high-precision measurements of turbulence, and moorings are a convenient and ubiquitous platform for making many kinds of measurements in the ocean. However, because of concerns that mooring motion can contaminate turbulence measurements and that acoustic Doppler profilers make middepth velocity measurements relatively easy, ADVs are not frequently deployed from moorings. This work demonstrates that inertial motion measurements can be used to reduce motion contamination from moored ADV velocity measurements. Three distinct mooring platforms were deployed in a tidal channel with inertial-motion-sensor-equipped ADVs. In each case, motion correction based on themore » inertial measurements reduces mooring motion contamination of velocity measurements. The spectra from these measurements are consistent with other measurements in tidal channels and have an f –5/3 slope at high frequencies - consistent with Kolmogorov's theory of isotropic turbulence. Motion correction also improves estimates of cross spectra and Reynolds stresses. A comparison of turbulence dissipation with flow speed and turbulence production indicates a bottom boundary layer production-dissipation balance during ebb and flood that is consistent with the strong tidal forcing at the site. Finally, these results indicate that inertial-motion-sensor-equipped ADVs are a valuable new tool for making high-precision turbulence measurements from moorings.« less

  8. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Kilcher, Levi F.; Thomson, Jim; Harding, Samuel

    Acoustic Doppler velocimeters (ADVs) are a valuable tool for making high-precision measurements of turbulence, and moorings are a convenient and ubiquitous platform for making many kinds of measurements in the ocean. However, because of concerns that mooring motion can contaminate turbulence measurements and that acoustic Doppler profilers make middepth velocity measurements relatively easy, ADVs are not frequently deployed from moorings. This work demonstrates that inertial motion measurements can be used to reduce motion contamination from moored ADV velocity measurements. Three distinct mooring platforms were deployed in a tidal channel with inertial-motion-sensor-equipped ADVs. In each case, motion correction based on themore » inertial measurements reduces mooring motion contamination of velocity measurements. The spectra from these measurements are consistent with other measurements in tidal channels and have an f –5/3 slope at high frequencies - consistent with Kolmogorov's theory of isotropic turbulence. Motion correction also improves estimates of cross spectra and Reynolds stresses. A comparison of turbulence dissipation with flow speed and turbulence production indicates a bottom boundary layer production-dissipation balance during ebb and flood that is consistent with the strong tidal forcing at the site. Finally, these results indicate that inertial-motion-sensor-equipped ADVs are a valuable new tool for making high-precision turbulence measurements from moorings.« less

  9. Thin-Slice Perception Develops Slowly

    ERIC Educational Resources Information Center

    Balas, Benjamin; Kanwisher, Nancy; Saxe, Rebecca

    2012-01-01

    Body language and facial gesture provide sufficient visual information to support high-level social inferences from "thin slices" of behavior. Given short movies of nonverbal behavior, adults make reliable judgments in a large number of tasks. Here we find that the high precision of adults' nonverbal social perception depends on the slow…

  10. Dynamic tracking down-conversion signal processing method based on reference signal for grating heterodyne interferometer

    NASA Astrophysics Data System (ADS)

    Wang, Guochao; Yan, Shuhua; Zhou, Weihong; Gu, Chenhui

    2012-08-01

    Traditional displacement measurement systems by grating, which purely make use of fringe intensity to implement fringe count and subdivision, have rigid demands for signal quality and measurement condition, so they are not easy to realize measurement with nanometer precision. Displacement measurement with the dual-wavelength and single-grating design takes advantage of the single grating diffraction theory and the heterodyne interference theory, solving quite well the contradiction between large range and high precision in grating displacement measurement. To obtain nanometer resolution and nanometer precision, high-power subdivision of interference fringes must be realized accurately. A dynamic tracking down-conversion signal processing method based on the reference signal is proposed. Accordingly, a digital phase measurement module to realize high-power subdivision on field programmable gate array (FPGA) was designed, as well as a dynamic tracking down-conversion module using phase-locked loop (PLL). Experiments validated that a carrier signal after down-conversion can constantly maintain close to 100 kHz, and the phase-measurement resolution and phase precision are more than 0.05 and 0.2 deg, respectively. The displacement resolution and the displacement precision, corresponding to the phase results, are 0.139 and 0.556 nm, respectively.

  11. Error measuring system of rotary Inductosyn

    NASA Astrophysics Data System (ADS)

    Liu, Chengjun; Zou, Jibin; Fu, Xinghe

    2008-10-01

    The inductosyn is a kind of high-precision angle-position sensor. It has important applications in servo table, precision machine tool and other products. The precision of inductosyn is calibrated by its error. It's an important problem about the error measurement in the process of production and application of the inductosyn. At present, it mainly depends on the method of artificial measurement to obtain the error of inductosyn. Therefore, the disadvantages can't be ignored such as the high labour intensity of the operator, the occurrent error which is easy occurred and the poor repeatability, and so on. In order to solve these problems, a new automatic measurement method is put forward in this paper which based on a high precision optical dividing head. Error signal can be obtained by processing the output signal of inductosyn and optical dividing head precisely. When inductosyn rotating continuously, its zero position error can be measured dynamically, and zero error curves can be output automatically. The measuring and calculating errors caused by man-made factor can be overcome by this method, and it makes measuring process more quickly, exactly and reliably. Experiment proves that the accuracy of error measuring system is 1.1 arc-second (peak - peak value).

  12. Development of a Pulsed 2-micron Laser Transmitter for CO2 Sensing from Space

    NASA Technical Reports Server (NTRS)

    Singh, Upendra N.; Yu, Jirong; Bai, Yingxin; Petros, Mulugeta; Menzies, Robert T.

    2011-01-01

    NASA Langley Research Center (LaRC), in collaboration with NASA Jet Propulsion Laboratory (JPL), is engaged in the development and demonstration of a highly efficient, versatile, 2-micron pulsed laser that can be used in a pulsed Differential Absorption Lidar (DIAL)/Integrated Path Differential Absorption (IPDA) instrument to make precise, high-resolution CO2 measurements to investigate sources, sinks, and fluxes of CO2. This laser transmitter will feature performance characteristics needed for an ASCENDS system that will be capable of delivering the CO2 measurement precision required by the Earth Science Decadal Survey (DS).

  13. Investigation Into Radiation-Induced Compaction of Zerodur (trademark)

    NASA Technical Reports Server (NTRS)

    Edwards, D. L.; Herren, K.; Hayden, M.; McDonald, K.; Sims, J. A.; Semmel, C. L.

    1996-01-01

    Zerodur is a low coefficient of thermal expansion glass-ceramic material. This property makes Zerodur an excellent material for high precision optical substrates. Functioning as a high precision optical substrate, a material must be dimensionally stable in the system operating environment. Published data indicate that Zerodur is dimensionally unstable when exposed to large doses of ionizing radiation. The dimensional instability is discussed as an increase in Zerodur density. This increase in density is described as a compaction. Experimental data showing proton-induced compaction of Zerodur is presented. The dependence of compaction on proton dose was determined to be a power law relationship.

  14. Investigation Into Radiation-Induced Compaction of Zerodur (trademark)

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Edwards, D.L.; Herren, K.; Hayden, M.

    1996-03-01

    Zerodur is a low coefficient of thermal expansion glass-ceramic material. This property makes Zerodur an excellent material for high precision optical substrates. Functioning as a high precision optical substrate, a material must be dimensionally stable in the system operating environment. Published data indicate that Zerodur is dimensionally unstable when exposed to large doses of ionizing radiation. The dimensional instability is discussed as an increase in Zerodur density. This increase in density is described as a compaction. Experimental data showing proton-induced compaction of Zerodur is presented. The dependence of compaction on proton dose was determined to be a power law relationship.

  15. High-precision branching ratio measurement for the superallowed β+ emitter Ga62

    NASA Astrophysics Data System (ADS)

    Finlay, P.; Ball, G. C.; Leslie, J. R.; Svensson, C. E.; Towner, I. S.; Austin, R. A. E.; Bandyopadhyay, D.; Chaffey, A.; Chakrawarthy, R. S.; Garrett, P. E.; Grinyer, G. F.; Hackman, G.; Hyland, B.; Kanungo, R.; Leach, K. G.; Mattoon, C. M.; Morton, A. C.; Pearson, C. J.; Phillips, A. A.; Ressler, J. J.; Sarazin, F.; Savajols, H.; Schumaker, M. A.; Wong, J.

    2008-08-01

    A high-precision branching ratio measurement for the superallowed β+ decay of Ga62 was performed at the Isotope Separator and Accelerator (ISAC) radioactive ion beam facility. The 8π spectrometer, an array of 20 high-purity germanium detectors, was employed to detect the γ rays emitted following Gamow-Teller and nonanalog Fermi β+ decays of Ga62, and the SCEPTAR plastic scintillator array was used to detect the emitted β particles. Thirty γ rays were identified following Ga62 decay, establishing the superallowed branching ratio to be 99.858(8)%. Combined with the world-average half-life and a recent high-precision Q-value measurement for Ga62, this branching ratio yields an ft value of 3074.3±1.1 s, making Ga62 among the most precisely determined superallowed ft values. Comparison between the superallowed ft value determined in this work and the world-average corrected F tmacr value allows the large nuclear-structure-dependent correction for Ga62 decay to be experimentally determined from the CVC hypothesis to better than 7% of its own value, the most precise experimental determination for any superallowed emitter. These results provide a benchmark for the refinement of the theoretical description of isospin-symmetry breaking in A⩾62 superallowed decays.

  16. In situ precision electrospinning as an effective delivery technique for cyanoacrylate medical glue with high efficiency and low toxicity.

    PubMed

    Dong, R H; Qin, C C; Qiu, X; Yan, X; Yu, M; Cui, L; Zhou, Y; Zhang, H D; Jiang, X Y; Long, Y Z

    2015-12-14

    The side effects or toxicity of cyanoacrylate used in vivo have been argued since its first application in wound closure. We propose an airflow-assisted in situ precision electrospinning apparatus as an applicator and make a detailed comparison with traditional spraying via in vitro and in vivo experiments. This novel method can not only improve operational performance and safety by precisely depositing cyanoacrylate fibers onto a wound, but significantly reduce the dosage of cyanoacrylate by almost 80%. A white blood cell count, liver function test and histological analysis prove that the in situ precision electrospinning applicator produces a better postoperative outcome, e.g., minor hepatocyte injury, moderate inflammation and the significant ability for liver regeneration. This in situ precision electrospinning method may thus dramatically broaden both civilian and military applications of cyanoacrylates.

  17. The prospects of pulsar timing with new-generation radio telescopes and the Square Kilometre Array.

    PubMed

    Stappers, B W; Keane, E F; Kramer, M; Possenti, A; Stairs, I H

    2018-05-28

    Pulsars are highly magnetized and rapidly rotating neutron stars. As they spin, the lighthouse-like beam of radio emission from their magnetic poles sweeps across the Earth with a regularity approaching that of the most precise clocks known. This precision combined with the extreme environments in which they are found, often in compact orbits with other neutron stars and white dwarfs, makes them excellent tools for studying gravity. Present and near-future pulsar surveys, especially those using the new generation of telescopes, will find more extreme binary systems and pulsars that are more precise 'clocks'. These telescopes will also greatly improve the precision to which we can measure the arrival times of the pulses. The Square Kilometre Array will revolutionize pulsar searches and timing precision. The increased number of sources will reveal rare sources, including possibly a pulsar-black hole binary, which can provide the most stringent tests of strong-field gravity. The improved timing precision will reveal new phenomena and also allow us to make a detection of gravitational waves in the nanohertz frequency regime. It is here where we expect to see the signature of the binary black holes that are formed as galaxies merge throughout cosmological history.This article is part of a discussion meeting issue 'The promises of gravitational-wave astronomy'. © 2018 The Author(s).

  18. Printable semiconductor structures and related methods of making and assembling

    DOEpatents

    Nuzzo, Ralph G.; Rogers, John A.; Menard, Etienne; Lee, Keon Jae; Khang; , Dahl-Young; Sun, Yugang; Meitl, Matthew; Zhu, Zhengtao; Ko, Heung Cho; Mack, Shawn

    2013-03-12

    The present invention provides a high yield pathway for the fabrication, transfer and assembly of high quality printable semiconductor elements having selected physical dimensions, shapes, compositions and spatial orientations. The compositions and methods of the present invention provide high precision registered transfer and integration of arrays of microsized and/or nanosized semiconductor structures onto substrates, including large area substrates and/or flexible substrates. In addition, the present invention provides methods of making printable semiconductor elements from low cost bulk materials, such as bulk silicon wafers, and smart-materials processing strategies that enable a versatile and commercially attractive printing-based fabrication platform for making a broad range of functional semiconductor devices.

  19. Printable semiconductor structures and related methods of making and assembling

    DOEpatents

    Nuzzo, Ralph G [Champaign, IL; Rogers, John A [Champaign, IL; Menard, Etienne [Durham, NC; Lee, Keon Jae [Tokyo, JP; Khang, Dahl-Young [Urbana, IL; Sun, Yugang [Westmont, IL; Meitl, Matthew [Raleigh, NC; Zhu, Zhengtao [Rapid City, SD; Ko, Heung Cho [Urbana, IL; Mack, Shawn [Goleta, CA

    2011-10-18

    The present invention provides a high yield pathway for the fabrication, transfer and assembly of high quality printable semiconductor elements having selected physical dimensions, shapes, compositions and spatial orientations. The compositions and methods of the present invention provide high precision registered transfer and integration of arrays of microsized and/or nanosized semiconductor structures onto substrates, including large area substrates and/or flexible substrates. In addition, the present invention provides methods of making printable semiconductor elements from low cost bulk materials, such as bulk silicon wafers, and smart-materials processing strategies that enable a versatile and commercially attractive printing-based fabrication platform for making a broad range of functional semiconductor devices.

  20. Printable semiconductor structures and related methods of making and assembling

    DOEpatents

    Nuzzo, Ralph G.; Rogers, John A.; Menard, Etienne; Lee, Keon Jae; Khang, Dahl-Young; Sun, Yugang; Meitl, Matthew; Zhu, Zhengtao; Ko, Heung Cho; Mack, Shawn

    2010-09-21

    The present invention provides a high yield pathway for the fabrication, transfer and assembly of high quality printable semiconductor elements having selected physical dimensions, shapes, compositions and spatial orientations. The compositions and methods of the present invention provide high precision registered transfer and integration of arrays of microsized and/or nanosized semiconductor structures onto substrates, including large area substrates and/or flexible substrates. In addition, the present invention provides methods of making printable semiconductor elements from low cost bulk materials, such as bulk silicon wafers, and smart-materials processing strategies that enable a versatile and commercially attractive printing-based fabrication platform for making a broad range of functional semiconductor devices.

  1. Composite adaptive control of belt polishing force for aero-engine blade

    NASA Astrophysics Data System (ADS)

    Zhsao, Pengbing; Shi, Yaoyao

    2013-09-01

    The existing methods for blade polishing mainly focus on robot polishing and manual grinding. Due to the difficulty in high-precision control of the polishing force, the blade surface precision is very low in robot polishing, in particular, quality of the inlet and exhaust edges can not satisfy the processing requirements. Manual grinding has low efficiency, high labor intensity and unstable processing quality, moreover, the polished surface is vulnerable to burn, and the surface precision and integrity are difficult to ensure. In order to further improve the profile accuracy and surface quality, a pneumatic flexible polishing force-exerting mechanism is designed and a dual-mode switching composite adaptive control(DSCAC) strategy is proposed, which combines Bang-Bang control and model reference adaptive control based on fuzzy neural network(MRACFNN) together. By the mode decision-making mechanism, Bang-Bang control is used to track the control command signal quickly when the actual polishing force is far away from the target value, and MRACFNN is utilized in smaller error ranges to improve the system robustness and control precision. Based on the mathematical model of the force-exerting mechanism, simulation analysis is implemented on DSCAC. Simulation results show that the output polishing force can better track the given signal. Finally, the blade polishing experiments are carried out on the designed polishing equipment. Experimental results show that DSCAC can effectively mitigate the influence of gas compressibility, valve dead-time effect, valve nonlinear flow, cylinder friction, measurement noise and other interference on the control precision of polishing force, which has high control precision, strong robustness, strong anti-interference ability and other advantages compared with MRACFNN. The proposed research achieves high-precision control of the polishing force, effectively improves the blade machining precision and surface consistency, and significantly reduces the surface roughness.

  2. Fundamentals of precision medicine

    PubMed Central

    Divaris, Kimon

    2018-01-01

    Imagine a world where clinicians make accurate diagnoses and provide targeted therapies to their patients according to well-defined, biologically-informed disease subtypes, accounting for individual differences in genetic make-up, behaviors, cultures, lifestyles and the environment. This is not as utopic as it may seem. Relatively recent advances in science and technology have led to an explosion of new information on what underlies health and what constitutes disease. These novel insights emanate from studies of the human genome and microbiome, their associated transcriptomes, proteomes and metabolomes, as well as epigenomics and exposomics—such ‘omics data can now be generated at unprecedented depth and scale, and at rapidly decreasing cost. Making sense and integrating these fundamental information domains to transform health care and improve health remains a challenge—an ambitious, laudable and high-yield goal. Precision dentistry is no longer a distant vision; it is becoming part of the rapidly evolving present. Insights from studies of the human genome and microbiome, their associated transcriptomes, proteomes and metabolomes, and epigenomics and exposomics have reached an unprecedented depth and scale. Much more needs to be done, however, for the realization of precision medicine in the oral health domain. PMID:29227115

  3. Photolithography-Based Patterning of Liquid Metal Interconnects for Monolithically Integrated Stretchable Circuits.

    PubMed

    Park, Chan Woo; Moon, Yu Gyeong; Seong, Hyejeong; Jung, Soon Won; Oh, Ji-Young; Na, Bock Soon; Park, Nae-Man; Lee, Sang Seok; Im, Sung Gap; Koo, Jae Bon

    2016-06-22

    We demonstrate a new patterning technique for gallium-based liquid metals on flat substrates, which can provide both high pattern resolution (∼20 μm) and alignment precision as required for highly integrated circuits. In a very similar manner as in the patterning of solid metal films by photolithography and lift-off processes, the liquid metal layer painted over the whole substrate area can be selectively removed by dissolving the underlying photoresist layer, leaving behind robust liquid patterns as defined by the photolithography. This quick and simple method makes it possible to integrate fine-scale interconnects with preformed devices precisely, which is indispensable for realizing monolithically integrated stretchable circuits. As a way for constructing stretchable integrated circuits, we propose a hybrid configuration composed of rigid device regions and liquid interconnects, which is constructed on a rigid substrate first but highly stretchable after being transferred onto an elastomeric substrate. This new method can be useful in various applications requiring both high-resolution and precisely aligned patterning of gallium-based liquid metals.

  4. High-Precision Distribution of Highly Stable Optical Pulse Trains with 8.8 × 10−19 instability

    PubMed Central

    Ning, B.; Zhang, S. Y.; Hou, D.; Wu, J. T.; Li, Z. B.; Zhao, J. Y.

    2014-01-01

    The high-precision distribution of optical pulse trains via fibre links has had a considerable impact in many fields. In most published work, the accuracy is still fundamentally limited by unavoidable noise sources, such as thermal and shot noise from conventional photodiodes and thermal noise from mixers. Here, we demonstrate a new high-precision timing distribution system that uses a highly precise phase detector to obviously reduce the effect of these limitations. Instead of using photodiodes and microwave mixers, we use several fibre Sagnac-loop-based optical-microwave phase detectors (OM-PDs) to achieve optical-electrical conversion and phase measurements, thereby suppressing the sources of noise and achieving ultra-high accuracy. The results of a distribution experiment using a 10-km fibre link indicate that our system exhibits a residual instability of 2.0 × 10−15 at1 s and8.8 × 10−19 at 40,000 s and an integrated timing jitter as low as 3.8 fs in a bandwidth of 1 Hz to 100 kHz. This low instability and timing jitter make it possible for our system to be used in the distribution of optical-clock signals or in applications that require extremely accurate frequency/time synchronisation. PMID:24870442

  5. A 256-channel, high throughput and precision time-to-digital converter with a decomposition encoding scheme in a Kintex-7 FPGA

    NASA Astrophysics Data System (ADS)

    Song, Z.; Wang, Y.; Kuang, J.

    2018-05-01

    Field Programmable Gate Arrays (FPGAs) made with 28 nm and more advanced process technology have great potentials for implementation of high precision time-to-digital convertors (TDC), because the delay cells in the tapped delay line (TDL) used for time interpolation are getting smaller and smaller. However, the bubble problems in the TDL status are becoming more complicated, which make it difficult to achieve TDCs on these chips with a high time precision. In this paper, we are proposing a novel decomposition encoding scheme, which not only can solve the bubble problem easily, but also has a high encoding efficiency. The potential of these chips to realize TDC can be fully released with the scheme. In a Xilinx Kintex-7 FPGA chip, we implemented a TDC system with 256 TDC channels, which doubles the number of TDC channels that our previous technique could achieve. Performances of all these TDC channels are evaluated. The average RMS time precision among them is 10.23 ps in the time-interval measurement range of (0–10 ns), and their measurement throughput reaches 277 M measures per second.

  6. Precision Timing of PSR J0437-4715: An Accurate Pulsar Distance, a High Pulsar Mass, and a Limit on the Variation of Newton's Gravitational Constant

    NASA Astrophysics Data System (ADS)

    Verbiest, J. P. W.; Bailes, M.; van Straten, W.; Hobbs, G. B.; Edwards, R. T.; Manchester, R. N.; Bhat, N. D. R.; Sarkissian, J. M.; Jacoby, B. A.; Kulkarni, S. R.

    2008-05-01

    Analysis of 10 years of high-precision timing data on the millisecond pulsar PSR J0437-4715 has resulted in a model-independent kinematic distance based on an apparent orbital period derivative, dot Pb , determined at the 1.5% level of precision (Dk = 157.0 +/- 2.4 pc), making it one of the most accurate stellar distance estimates published to date. The discrepancy between this measurement and a previously published parallax distance estimate is attributed to errors in the DE200 solar system ephemerides. The precise measurement of dot Pb allows a limit on the variation of Newton's gravitational constant, |Ġ/G| <= 23 × 10-12 yr-1. We also constrain any anomalous acceleration along the line of sight to the pulsar to |a⊙/c| <= 1.5 × 10-18 s-1 at 95% confidence, and derive a pulsar mass, mpsr = 1.76 +/- 0.20 M⊙, one of the highest estimates so far obtained.

  7. High-Sensitivity Fiber-Optic Ultrasound Sensors for Medical Imaging Applications

    PubMed Central

    Wen, H.; Wiesler, D.G.; Tveten, A.; Danver, B.; Dandridge, A.

    2010-01-01

    This paper presents several designs of high-sensitivity, compact fiber-optic ultrasound sensors that may be used for medical imaging applications. These sensors translate ultrasonic pulses into strains in single-mode optical fibers, which are measured with fiber-based laser interferometers at high precision. The sensors are simpler and less expensive to make than piezoelectric sensors, and are not susceptible to electromagnetic interference. It is possible to make focal sensors with these designs, and several schemes are discussed. Because of the minimum bending radius of optical fibers, the designs are suitable for single element sensors rather than for arrays. PMID:9691368

  8. Precision digital control systems

    NASA Astrophysics Data System (ADS)

    Vyskub, V. G.; Rozov, B. S.; Savelev, V. I.

    This book is concerned with the characteristics of digital control systems of great accuracy. A classification of such systems is considered along with aspects of stabilization, programmable control applications, digital tracking systems and servomechanisms, and precision systems for the control of a scanning laser beam. Other topics explored are related to systems of proportional control, linear devices and methods for increasing precision, approaches for further decreasing the response time in the case of high-speed operation, possibilities for the implementation of a logical control law, and methods for the study of precision digital control systems. A description is presented of precision automatic control systems which make use of electronic computers, taking into account the existing possibilities for an employment of computers in automatic control systems, approaches and studies required for including a computer in such control systems, and an analysis of the structure of automatic control systems with computers. Attention is also given to functional blocks in the considered systems.

  9. The influence of chronotype on making music: circadian fluctuations in pianists' fine motor skills

    PubMed Central

    Van Vugt, Floris T.; Treutler, Katharina; Altenmüller, Eckart; Jabusch, Hans-Christian

    2013-01-01

    Making music on a professional level requires a maximum of sensorimotor precision. Chronotype-dependent fluctuations of sensorimotor precision in the course of the day may prove a challenge for musicians because public performances or recordings are usually scheduled at fixed times of the day. We investigated pianists' sensorimotor timing precision in a scale playing task performed in the morning and in the evening. Participants' chronotype was established through the Munich Chrono-Type Questionnaire, where mid-sleep time served as a marker for the individual chronotypes. Twenty-one piano students were included in the study. Timing precision was decomposed into consistent within-trial variability (irregularity) and residual, between-trial variability (instability). The timing patterns of late chronotype pianists were more stable in the evening than in the morning, whereas early chronotype pianists did not show a difference between the two recording timepoints. In sum, the present results indicate that even highly complex sensorimotor tasks such as music playing are affected by interactions between chronotype and the time of day. Thus, even long-term, massed practice of these expert musicians has not been able to wash out circadian fluctuations in performance. PMID:23847515

  10. The influence of chronotype on making music: circadian fluctuations in pianists' fine motor skills.

    PubMed

    Van Vugt, Floris T; Treutler, Katharina; Altenmüller, Eckart; Jabusch, Hans-Christian

    2013-01-01

    Making music on a professional level requires a maximum of sensorimotor precision. Chronotype-dependent fluctuations of sensorimotor precision in the course of the day may prove a challenge for musicians because public performances or recordings are usually scheduled at fixed times of the day. We investigated pianists' sensorimotor timing precision in a scale playing task performed in the morning and in the evening. Participants' chronotype was established through the Munich Chrono-Type Questionnaire, where mid-sleep time served as a marker for the individual chronotypes. Twenty-one piano students were included in the study. Timing precision was decomposed into consistent within-trial variability (irregularity) and residual, between-trial variability (instability). The timing patterns of late chronotype pianists were more stable in the evening than in the morning, whereas early chronotype pianists did not show a difference between the two recording timepoints. In sum, the present results indicate that even highly complex sensorimotor tasks such as music playing are affected by interactions between chronotype and the time of day. Thus, even long-term, massed practice of these expert musicians has not been able to wash out circadian fluctuations in performance.

  11. Collaborative Manufacturing for Small-Medium Enterprises

    NASA Astrophysics Data System (ADS)

    Irianto, D.

    2016-02-01

    Manufacturing systems involve decisions concerning production processes, capacity, planning, and control. In a MTO manufacturing systems, strategic decisions concerning fulfilment of customer requirement, manufacturing cost, and due date of delivery are the most important. In order to accelerate the decision making process, research on decision making structure when receiving order and sequencing activities under limited capacity is required. An effective decision making process is typically required by small-medium components and tools maker as supporting industries to large industries. On one side, metal small-medium enterprises are expected to produce parts, components or tools (i.e. jigs, fixture, mold, and dies) with high precision, low cost, and exact delivery time. On the other side, a metal small- medium enterprise may have weak bargaining position due to aspects such as low production capacity, limited budget for material procurement, and limited high precision machine and equipment. Instead of receiving order exclusively, a small-medium enterprise can collaborate with other small-medium enterprise in order to fulfill requirements high quality, low manufacturing cost, and just in time delivery. Small-medium enterprises can share their best capabilities to form effective supporting industries. Independent body such as community service at university can take a role as a collaboration manager. The Laboratory of Production Systems at Bandung Institute of Technology has implemented shared manufacturing systems for small-medium enterprise collaboration.

  12. Method for measuring retardation of infrared wave-plate by modulated-polarized visible light

    NASA Astrophysics Data System (ADS)

    Zhang, Ying; Song, Feijun

    2012-11-01

    A new method for precisely measuring the optical phase retardation of wave-plates in the infrared spectral region is presented by using modulated-polarized visible light. An electro-optic modulator is used to accurately determine the zero point by the frequency-doubled signal of the Modulated-polarized light. A Babinet-Soleil compensator is employed to make the phase delay compensation. Based on this method, an instrument is set up to measure the retardations of the infrared wave-plates with visible region laser. Measurement results with high accuracy and sound repetition are obtained by simple calculation. Its measurement precision is less than and repetitive precision is within 0.3%.

  13. Removal of Lattice Imperfections that Impact the Optical Quality of Ti:Sapphire using Advanced Magnetorheological Finishing Techniques

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Menapace, J A; Schaffers, K I; Bayramian, A J

    2007-10-09

    Ti:sapphire has become the premier lasing medium material for use in solid-state femtosecond high-peak power laser systems because of its wide wavelength tuning range. With a tuneable range from 680 to 1100 nm, peaking at 800 nm, Ti:sapphire lasing crystals can easily be tuned to the required pump wavelength and provide very high pump brightness due to their good beam quality and high output power of typically several watts. Femtosecond lasers are used for precision cutting and machining of materials ranging from steel to tooth enamel to delicate heart tissue and high explosives. These ultra-short pulses are too brief tomore » transfer heat or shock to the material being cut, which means that cutting, drilling, and machining occur with virtually no damage to surrounding material. Furthermore, these lasers can cut with high precision, making hairline cuts of less than 100 microns in thick materials along a computer-generated path. Extension of laser output to higher energies is limited by the size of the amplification medium. Yields of high quality large diameter crystals have been constrained by lattice distortions that may appear in the boule limiting the usable area from which high quality optics can be harvested. Lattice distortions affect the transmitted wavefront of these optics which ultimately limits the high-end power output and efficiency of the laser system, particularly when operated in multi-pass mode. To make matters even more complicated, Ti:sapphire is extremely hard (Mohs hardness of 9 with diamond being 10) which makes it extremely difficult to accurately polish using conventional methods without subsurface damage or significant wavefront error. In this presentation, we demonstrate for the first time that Magnetorheological finishing (MRF) can be used to compensate for the lattice distortions in Ti:sapphire by perturbing the transmitted wavefront. The advanced MRF techniques developed allow for precise polishing of the optical inverse of lattice distortions with magnitudes of about 70 nm in optical path difference onto one or both of the optical surfaces to produce high quality optics from otherwise unusable Ti:sapphire crystals. The techniques include interferometric, software, and machine modifications to precisely locate and polish sub-millimeter sites onto the optical surfaces that can not be polished into the optics conventionally. This work may allow extension of Ti:sapphire based systems to peak powers well beyond one petawatt.« less

  14. Evaluation of the FIR Example using Xilinx Vivado High-Level Synthesis Compiler

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Jin, Zheming; Finkel, Hal; Yoshii, Kazutomo

    Compared to central processing units (CPUs) and graphics processing units (GPUs), field programmable gate arrays (FPGAs) have major advantages in reconfigurability and performance achieved per watt. This development flow has been augmented with high-level synthesis (HLS) flow that can convert programs written in a high-level programming language to Hardware Description Language (HDL). Using high-level programming languages such as C, C++, and OpenCL for FPGA-based development could allow software developers, who have little FPGA knowledge, to take advantage of the FPGA-based application acceleration. This improves developer productivity and makes the FPGA-based acceleration accessible to hardware and software developers. Xilinx Vivado HLSmore » compiler is a high-level synthesis tool that enables C, C++ and System C specification to be directly targeted into Xilinx FPGAs without the need to create RTL manually. The white paper [1] published recently by Xilinx uses a finite impulse response (FIR) example to demonstrate the variable-precision features in the Vivado HLS compiler and the resource and power benefits of converting floating point to fixed point for a design. To get a better understanding of variable-precision features in terms of resource usage and performance, this report presents the experimental results of evaluating the FIR example using Vivado HLS 2017.1 and a Kintex Ultrascale FPGA. In addition, we evaluated the half-precision floating-point data type against the double-precision and single-precision data type and present the detailed results.« less

  15. Precision Column CO2 Measurement from Space Using Broad Band LIDAR

    NASA Technical Reports Server (NTRS)

    Heaps, William S.

    2009-01-01

    In order to better understand the budget of carbon dioxide in the Earth's atmosphere it is necessary to develop a global high precision understanding of the carbon dioxide column. To uncover the missing sink" that is responsible for the large discrepancies in the budget as we presently understand it, calculation has indicated that measurement accuracy of 1 ppm is necessary. Because typical column average CO2 has now reached 380 ppm this represents a precision on the order of 0.25% for these column measurements. No species has ever been measured from space at such a precision. In recognition of the importance of understanding the CO2 budget to evaluate its impact on global warming the National Research Council in its decadal survey report to NASA recommended planning for a laser based total CO2 mapping mission in the near future. The extreme measurement accuracy requirements on this mission places very strong constraints on the laser system used for the measurement. This work presents an overview of the characteristics necessary in a laser system used to make this measurement. Consideration is given to the temperature dependence, pressure broadening, and pressure shift of the CO2 lines themselves and how these impact the laser system characteristics. We are examining the possibility of making precise measurements of atmospheric carbon dioxide using a broad band source of radiation. This means that many of the difficulties in wavelength control can be treated in the detector portion of the system rather than the laser source. It also greatly reduces the number of individual lasers required to make a measurement. Simplifications such as these are extremely desirable for systems designed to operate from space.

  16. A high-precision velocity measuring system design for projectiles based on S-shaped laser screen

    NASA Astrophysics Data System (ADS)

    Liu, Huayi; Qian, Zheng; Yu, Hao; Li, Yutao

    2018-03-01

    The high-precision measurement of the velocity of high-speed flying projectile is of great significance for the evaluation and development of modern weapons. The velocity of the high-speed flying projectile is usually measured by laser screen velocity measuring system. But this method cannot achieve the repeated measurements, so we cannot make an indepth evaluation of the uncertainty about the measuring system. This paper presents a design based on S-shaped laser screen velocity measuring system. This design can achieve repeated measurements. Therefore, it can effectively reduce the uncertainty of the velocity measuring system. In addition, we made a detailed analysis of the uncertainty of the measuring system. The measurement uncertainty is 0.2% when the velocity of the projectile is about 200m/s.

  17. Method for making precisely configured flakes useful in optical devices

    DOEpatents

    Trajkovska-Petkoska, Anka [Rochester, NY; Jacobs, Stephen D [Pittsford, NY; Kosc, Tanya Z [Rochester, NY; Marshall, Kenneth L [Rochester, NY

    2007-07-03

    Precisely configured, especially of geometric shape, flakes of liquid crystal material are made using a mechanically flexible polymer mold with wells having shapes which are precisely configured by making the mold with a photolithographically manufactured or laser printed master. The polymer liquid crystal is poured into the wells in the flexible mold. When the liquid crystal material has solidified, the flexible mold is bent and the flakes are released and collected for use in making an electrooptical cell utilizing the liquid crystal flakes as the active element therein.

  18. High-accuracy 3D measurement system based on multi-view and structured light

    NASA Astrophysics Data System (ADS)

    Li, Mingyue; Weng, Dongdong; Li, Yufeng; Zhang, Longbin; Zhou, Haiyun

    2013-12-01

    3D surface reconstruction is one of the most important topics in Spatial Augmented Reality (SAR). Using structured light is a simple and rapid method to reconstruct the objects. In order to improve the precision of 3D reconstruction, we present a high-accuracy multi-view 3D measurement system based on Gray-code and Phase-shift. We use a camera and a light projector that casts structured light patterns on the objects. In this system, we use only one camera to take photos on the left and right sides of the object respectively. In addition, we use VisualSFM to process the relationships between each perspective, so the camera calibration can be omitted and the positions to place the camera are no longer limited. We also set appropriate exposure time to make the scenes covered by gray-code patterns more recognizable. All of the points above make the reconstruction more precise. We took experiments on different kinds of objects, and a large number of experimental results verify the feasibility and high accuracy of the system.

  19. -Omic and Electronic Health Record Big Data Analytics for Precision Medicine.

    PubMed

    Wu, Po-Yen; Cheng, Chih-Wen; Kaddi, Chanchala D; Venugopalan, Janani; Hoffman, Ryan; Wang, May D

    2017-02-01

    Rapid advances of high-throughput technologies and wide adoption of electronic health records (EHRs) have led to fast accumulation of -omic and EHR data. These voluminous complex data contain abundant information for precision medicine, and big data analytics can extract such knowledge to improve the quality of healthcare. In this paper, we present -omic and EHR data characteristics, associated challenges, and data analytics including data preprocessing, mining, and modeling. To demonstrate how big data analytics enables precision medicine, we provide two case studies, including identifying disease biomarkers from multi-omic data and incorporating -omic information into EHR. Big data analytics is able to address -omic and EHR data challenges for paradigm shift toward precision medicine. Big data analytics makes sense of -omic and EHR data to improve healthcare outcome. It has long lasting societal impact.

  20. A fiducial skull marker for precise MRI-based stereotaxic surgery in large animal models.

    PubMed

    Glud, Andreas Nørgaard; Bech, Johannes; Tvilling, Laura; Zaer, Hamed; Orlowski, Dariusz; Fitting, Lise Moberg; Ziedler, Dora; Geneser, Michael; Sangill, Ryan; Alstrup, Aage Kristian Olsen; Bjarkam, Carsten Reidies; Sørensen, Jens Christian Hedemann

    2017-06-15

    Stereotaxic neurosurgery in large animals is used widely in different sophisticated models, where precision is becoming more crucial as desired anatomical target regions are becoming smaller. Individually calculated coordinates are necessary in large animal models with cortical and subcortical anatomical differences. We present a convenient method to make an MRI-visible skull fiducial for 3D MRI-based stereotaxic procedures in larger experimental animals. Plastic screws were filled with either copper-sulfate solution or MRI-visible paste from a commercially available cranial head marker. The screw fiducials were inserted in the animal skulls and T1 weighted MRI was performed allowing identification of the inserted skull marker. Both types of fiducial markers were clearly visible on the MRÍs. This allows high precision in the stereotaxic space. The use of skull bone based fiducial markers gives high precision for both targeting and evaluation of stereotaxic systems. There are no metal artifacts and the fiducial is easily removed after surgery. The fiducial marker can be used as a very precise reference point, either for direct targeting or in evaluation of other stereotaxic systems. Copyright © 2017 Elsevier B.V. All rights reserved.

  1. Demonstration of a Fast, Precise Propane Measurement Using Infrared Spectroscopy

    NASA Astrophysics Data System (ADS)

    Zahniser, M. S.; Roscioli, J. R.; Nelson, D. D.; Herndon, S. C.

    2016-12-01

    Propane is one of the primary components of emissions from natural gas extraction and processing activities. In addition to being an air pollutant, its ratio to other hydrocarbons such as methane and ethane can serve as a "fingerprint" of a particular facility or process, aiding in identifying emission sources. Quantifying propane has typically required laboratory analysis of flask samples, resulting in low temporal resolution and making plume-based measurements infeasible. Here we demonstrate fast (1-second), high precision (<300 ppt) measurements of propane using high resolution mid-infrared spectroscopy at 2967 wavenumbers. In addition, we explore the impact of nearby water and ethane absorption lines on the accuracy and precision of the propane measurement. Finally, we discuss development of a dual-laser instrument capable of simultaneous measurements of methane, ethane, and propane (the C1-C3 compounds), all within a small spatial package that can be easily deployed aboard a mobile platform.

  2. Parametric geometric model and hydrodynamic shape optimization of a flying-wing structure underwater glider

    NASA Astrophysics Data System (ADS)

    Wang, Zhen-yu; Yu, Jian-cheng; Zhang, Ai-qun; Wang, Ya-xing; Zhao, Wen-tao

    2017-12-01

    Combining high precision numerical analysis methods with optimization algorithms to make a systematic exploration of a design space has become an important topic in the modern design methods. During the design process of an underwater glider's flying-wing structure, a surrogate model is introduced to decrease the computation time for a high precision analysis. By these means, the contradiction between precision and efficiency is solved effectively. Based on the parametric geometry modeling, mesh generation and computational fluid dynamics analysis, a surrogate model is constructed by adopting the design of experiment (DOE) theory to solve the multi-objects design optimization problem of the underwater glider. The procedure of a surrogate model construction is presented, and the Gaussian kernel function is specifically discussed. The Particle Swarm Optimization (PSO) algorithm is applied to hydrodynamic design optimization. The hydrodynamic performance of the optimized flying-wing structure underwater glider increases by 9.1%.

  3. A flexible 32-channel time-to-digital converter implemented in a Xilinx Zynq-7000 field programmable gate array

    NASA Astrophysics Data System (ADS)

    Wang, Yonggang; Kuang, Jie; Liu, Chong; Cao, Qiang; Li, Deng

    2017-03-01

    A high performance multi-channel time-to-digital converter (TDC) is implemented in a Xilinx Zynq-7000 field programmable gate array (FPGA). It can be flexibly configured as either 32 TDC channels with 9.9 ps time-interval RMS precision, 16 TDC channels with 6.9 ps RMS precision, or 8 TDC channels with 5.8 ps RMS precision. All TDCs have a 380 M Samples/second measurement throughput and a 2.63 ns measurement dead time. The performance consistency and temperature dependence of TDC channels are also evaluated. Because Zynq-7000 FPGA family integrates a feature-rich dual-core ARM based processing system and 28 nm Xilinx programmable logic in a single device, the realization of high performance TDCs on it will make the platform more widely used in time-measuring related applications.

  4. Progress at the TITAN-EBIT

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Klawitter, R.; Alanssari, M.; Frekers, D.

    2015-01-09

    Precision mass measurements of short-lived isotopes provide insight into a wide array of physics, including nuclear structure, nucleosynthesis, and tests of the Standard Model. The precision of Penning trap mass spectrometry (PTMS) measurements is limited by the lifetime of the isotopes of interest, but scales proportionally with their charge state q, making highly charged ions attractive for mass measurements of nuclides far from stability. TITAN, TRIUMF's Ion Trap(s) for Atomic and Nuclear science, is currently the only setup in the world coupling an EBIT to a rare isotope facility for the purpose of PTMS. Charge breeding ions for Penning trapmore » mass spectrometry, however, entails specific set of challenges. To make use of its potential, efficiencies have to be high, breeding times have to be short and the ion energy spread has to be small. An overview of the TITAN facility and charge-breeding program is given, current and future developments are highlighted and some selected results are presented.« less

  5. A highly versatile and easily configurable system for plant electrophysiology.

    PubMed

    Gunsé, Benet; Poschenrieder, Charlotte; Rankl, Simone; Schröeder, Peter; Rodrigo-Moreno, Ana; Barceló, Juan

    2016-01-01

    In this study we present a highly versatile and easily configurable system for measuring plant electrophysiological parameters and ionic flow rates, connected to a computer-controlled highly accurate positioning device. The modular software used allows easy customizable configurations for the measurement of electrophysiological parameters. Both the operational tests and the experiments already performed have been fully successful and rendered a low noise and highly stable signal. Assembly, programming and configuration examples are discussed. The system is a powerful technique that not only gives precise measuring of plant electrophysiological status, but also allows easy development of ad hoc configurations that are not constrained to plant studies. •We developed a highly modular system for electrophysiology measurements that can be used either in organs or cells and performs either steady or dynamic intra- and extracellular measurements that takes advantage of the easiness of visual object-oriented programming.•High precision accuracy in data acquisition under electrical noisy environments that allows it to run even in a laboratory close to electrical equipment that produce electrical noise.•The system makes an improvement of the currently used systems for monitoring and controlling high precision measurements and micromanipulation systems providing an open and customizable environment for multiple experimental needs.

  6. Thermo-mechanical performance of precision C/SiC mounts

    NASA Astrophysics Data System (ADS)

    Goodman, William A.; Mueller, Claus E.; Jacoby, Marc T.; Wells, Jim D.

    2001-12-01

    For complex shaped, lightweight, high precision opto- mechanical structures that must operate in adverse environments and over wide ranges of temperature, we consider IABG's optical grade silicon carbide composite ceramic (C/SiC) as the material of choice. C/SiC employs conventional NC machining/milling equipment to rapidly fabricate near-net shape parts, providing substantial schedule, cost, and risk savings for high precision components. Unlike powder based SiC ceramics, C/SiC does not experience significant shrinkage during processing, nor does it suffer from incomplete densification. If required, e.g. for large-size components, a fully-monolithic ceramic joining technique can be applied. Generally, the thermal and mechanical properties of C/SiC are tunable in certain ranges by modifying certain process steps. This paper focuses on the thermo-mechanical performance of new, high precision mounts designed by Schafer Corporation and manufactured by IABG. The mounts were manufactured using standard optical grade C/SiC (formulation internally called A-3). The A-3 formulation has a near-perfect CTE match with silicon, making it the ideal material to athermally support Schafer produced Silicon Lightweight Mirrors (SLMs) that will operate in a cryogenic environment. Corresponding thermo- mechanical testing and analysis is presented in this manuscript.

  7. The proton radius puzzle

    NASA Astrophysics Data System (ADS)

    Bonesini, Maurizio

    2017-12-01

    The FAMU (Fisica degli Atomi Muonici) experiment has the goal to measure precisely the proton Zemach radius, thus contributing to the solution of the so-called proton radius "puzzle". To this aim, it makes use of a high-intensity pulsed muon beam at RIKEN-RAL impinging on a cryogenic hydrogen target with an high-Z gas admixture and a tunable mid-IR high power laser, to measure the hyperfine (HFS) splitting of the 1S state of the muonic hydrogen. From the value of the exciting laser frequency, the energy of the HFS transition may be derived with high precision ( 10-5) and thus, via QED calculations, the Zemach radius of the proton. The experimental apparatus includes a precise fiber-SiPMT beam hodoscope and a crown of eight LaBr3 crystals and a few HPGe detectors for detection of the emitted characteristic X-rays. Preliminary runs to optimize the gas target filling and its operating conditions have been taken in 2014 and 2015-2016. The final run, with the pump laser to drive the HFS transition, is expected in 2018.

  8. Design of automatic leveling and centering system of theodolite

    NASA Astrophysics Data System (ADS)

    Liu, Chun-tong; He, Zhen-Xin; Huang, Xian-xiang; Zhan, Ying

    2012-09-01

    To realize the theodolite automation and improve the azimuth Angle measurement instrument, the theodolite automatic leveling and centering system with the function of leveling error compensation is designed, which includes the system solution, key components selection, the mechanical structure of leveling and centering, and system software solution. The redesigned leveling feet are driven by the DC servo motor; and the electronic control center device is installed. Using high precision of tilt sensors as horizontal skew detection sensors ensures the effectiveness of the leveling error compensation. Aiming round mark center is located using digital image processing through surface array CCD; and leveling measurement precision can reach the pixel level, which makes the theodolite accurate centering possible. Finally, experiments are conducted using the automatic leveling and centering system of the theodolite. The results show the leveling and centering system can realize automatic operation with high centering accuracy of 0.04mm.The measurement precision of the orientation angle after leveling error compensation is improved, compared with that of in the traditional method. Automatic leveling and centering system of theodolite can satisfy the requirements of the measuring precision and its automation.

  9. A new Ultra Precision Interferometer for absolute length measurements down to cryogenic temperatures

    NASA Astrophysics Data System (ADS)

    Schödel, R.; Walkov, A.; Zenker, M.; Bartl, G.; Meeß, R.; Hagedorn, D.; Gaiser, C.; Thummes, G.; Heltzel, S.

    2012-09-01

    A new Ultra Precision Interferometer (UPI) was built at Physikalisch-Technische Bundesanstalt. As its precursor, the precision interferometer, it was designed for highly precise absolute length measurements of prismatic bodies, e.g. gauge blocks, under well-defined temperature conditions and pressure, making use of phase stepping imaging interferometry. The UPI enables a number of enhanced features, e.g. it is designed for a much better lateral resolution and better temperature stability. In addition to the original concept, the UPI is equipped with an external measurement pathway (EMP) in which a prismatic body can be placed alternatively. The temperature of the EMP can be controlled in a much wider range compared to the temperature of the interferometer's main chamber. An appropriate cryostat system, a precision temperature measurement system and improved imaging interferometry were established to permit absolute length measurements down to cryogenic temperature, demonstrated for the first time ever. Results of such measurements are important for studying thermal expansion of materials from room temperature towards less than 10 K.

  10. Double Arm Linkage precision Linear motion (DALL) Carriage, a simplified, rugged, high performance linear motion stage for the moving mirror of an Fourier Transform Spectrometer or other system requiring precision linear motion

    NASA Astrophysics Data System (ADS)

    Johnson, Kendall B.; Hopkins, Greg

    2017-08-01

    The Double Arm Linkage precision Linear motion (DALL) carriage has been developed as a simplified, rugged, high performance linear motion stage. Initially conceived as a moving mirror stage for the moving mirror of a Fourier Transform Spectrometer (FTS), it is applicable to any system requiring high performance linear motion. It is based on rigid double arm linkages connecting a base to a moving carriage through flexures. It is a monolithic design. The system is fabricated from one piece of material including the flexural elements, using high precision machining. The monolithic design has many advantages. There are no joints to slip or creep and there are no CTE (coefficient of thermal expansion) issues. This provides a stable, robust design, both mechanically and thermally and is expected to provide a wide operating temperature range, including cryogenic temperatures, and high tolerance to vibration and shock. Furthermore, it provides simplicity and ease of implementation, as there is no assembly or alignment of the mechanism. It comes out of the machining operation aligned and there are no adjustments. A prototype has been fabricated and tested, showing superb shear performance and very promising tilt performance. This makes it applicable to both corner cube and flat mirror FTS systems respectively.

  11. Predicting the Oxygen-Binding Properties of Platinum Nanoparticle Ensembles by Combining High-Precision Electron Microscopy and Density Functional Theory.

    PubMed

    Aarons, Jolyon; Jones, Lewys; Varambhia, Aakash; MacArthur, Katherine E; Ozkaya, Dogan; Sarwar, Misbah; Skylaris, Chris-Kriton; Nellist, Peter D

    2017-07-12

    Many studies of heterogeneous catalysis, both experimental and computational, make use of idealized structures such as extended surfaces or regular polyhedral nanoparticles. This simplification neglects the morphological diversity in real commercial oxygen reduction reaction (ORR) catalysts used in fuel-cell cathodes. Here we introduce an approach that combines 3D nanoparticle structures obtained from high-throughput high-precision electron microscopy with density functional theory. Discrepancies between experimental observations and cuboctahedral/truncated-octahedral particles are revealed and discussed using a range of widely used descriptors, such as electron-density, d-band centers, and generalized coordination numbers. We use this new approach to determine the optimum particle size for which both detrimental surface roughness and particle shape effects are minimized.

  12. -Omic and Electronic Health Records Big Data Analytics for Precision Medicine

    PubMed Central

    Wu, Po-Yen; Cheng, Chih-Wen; Kaddi, Chanchala D.; Venugopalan, Janani; Hoffman, Ryan; Wang, May D.

    2017-01-01

    Objective Rapid advances of high-throughput technologies and wide adoption of electronic health records (EHRs) have led to fast accumulation of -omic and EHR data. These voluminous complex data contain abundant information for precision medicine, and big data analytics can extract such knowledge to improve the quality of health care. Methods In this article, we present -omic and EHR data characteristics, associated challenges, and data analytics including data pre-processing, mining, and modeling. Results To demonstrate how big data analytics enables precision medicine, we provide two case studies, including identifying disease biomarkers from multi-omic data and incorporating -omic information into EHR. Conclusion Big data analytics is able to address –omic and EHR data challenges for paradigm shift towards precision medicine. Significance Big data analytics makes sense of –omic and EHR data to improve healthcare outcome. It has long lasting societal impact. PMID:27740470

  13. Evaluating the MEDLINE Core Clinical Journals filter: data-driven evidence assessing clinical utility.

    PubMed

    Klein-Fedyshin, Michele; Ketchum, Andrea M; Arnold, Robert M; Fedyshin, Peter J

    2014-12-01

    MEDLINE offers the Core Clinical Journals filter to limit to clinically useful journals. To determine its effectiveness for searching and patient-centric decision making, this study compared literature used for Morning Report in Internal Medicine with journals in the filter. An EndNote library with references answering 327 patient-related questions during Morning Report from 2007 to 2012 was exported to a file listing variables including designated Core Clinical Journal, Impact Factor, date used and medical subject. Bradford's law of scattering was applied ranking the journals and reflecting their clinical utility. Recall (sensitivity) and precision of the Core Morning Report journals and non-Core set was calculated. This study applied bibliometrics to compare the 628 articles used against these criteria to determine journals impacting decision making. Analysis shows 30% of clinically used articles are from the Core Clinical Journals filter and 16% of the journals represented are Core titles. When Bradford-ranked, 55% of the top 20 journals are Core. Articles <5 years old furnish 63% of sources used. Among the 63 Morning Report subjects, 55 have <50% precision and 41 have <50% recall including 37 subjects with 0% precision and 0% recall. Low usage of publications within the Core Clinical Journals filter indicates less relevance for hospital-based care. The divergence from high-impact medicine titles suggests clinically valuable journals differ from academically important titles. With few subjects demonstrating high recall or precision, the MEDLINE Core Clinical Journals filter may require a review and update to better align with current clinical needs. © 2014 John Wiley & Sons, Ltd.

  14. High resolution remote sensing for reducing uncertainties in urban forest carbon offset life cycle assessments.

    PubMed

    Tigges, Jan; Lakes, Tobia

    2017-10-04

    Urban forests reduce greenhouse gas emissions by storing and sequestering considerable amounts of carbon. However, few studies have considered the local scale of urban forests to effectively evaluate their potential long-term carbon offset. The lack of precise, consistent and up-to-date forest details is challenging for long-term prognoses. Therefore, this review aims to identify uncertainties in urban forest carbon offset assessment and discuss the extent to which such uncertainties can be reduced by recent progress in high resolution remote sensing. We do this by performing an extensive literature review and a case study combining remote sensing and life cycle assessment of urban forest carbon offset in Berlin, Germany. Recent progress in high resolution remote sensing and methods is adequate for delivering more precise details on the urban tree canopy, individual tree metrics, species, and age structures compared to conventional land use/cover class approaches. These area-wide consistent details can update life cycle inventories for more precise future prognoses. Additional improvements in classification accuracy can be achieved by a higher number of features derived from remote sensing data of increasing resolution, but first studies on this subject indicated that a smart selection of features already provides sufficient data that avoids redundancies and enables more efficient data processing. Our case study from Berlin could use remotely sensed individual tree species as consistent inventory of a life cycle assessment. However, a lack of growth, mortality and planting data forced us to make assumptions, therefore creating uncertainty in the long-term prognoses. Regarding temporal changes and reliable long-term estimates, more attention is required to detect changes of gradual growth, pruning and abrupt changes in tree planting and mortality. As such, precise long-term urban ecological monitoring using high resolution remote sensing should be intensified, especially due to increasing climate change effects. This is important for calibrating and validating recent prognoses of urban forest carbon offset, which have so far scarcely addressed longer timeframes. Additionally, higher resolution remote sensing of urban forest carbon estimates can improve upscaling approaches, which should be extended to reach a more precise global estimate for the first time. Urban forest carbon offset can be made more relevant by making more standardized assessments available for science and professional practitioners, and the increasing availability of high resolution remote sensing data and the progress in data processing allows for precisely that.

  15. ZERODUR expanding capabilities and capacity for future spaceborne and ground-based telescopes

    NASA Astrophysics Data System (ADS)

    Westerhoff, Thomas; Werner, Thomas

    2017-09-01

    The glass ceramic ZERODUR is well known for its extremely low coefficient of thermal expansion making it one of the key materials for ultra-precision application such as IC and LCD Lithography, High-end Metrology, Aviation and space borne or ground based Astronomy. The steady growth of demand for more precision in those applications together with a growing number of precision systems and components is requesting the ability to on hand increase precision in manufacturing. Additionally, there is a need to increase production capacity of ZERODUR CNC machined products in parallel. This paper reports on the measures SCHOTT is realizing to feed the continuously increasing demand on high precision material and components. Next to a second melting tank additional capacity is going to be installed along the entire value stream of ZERODUR production. Features of new CNC machining capabilities in the two and four meter class will be reported allowing to provide tighter tolerance on mirror surface figure together with reduced sub surface damage in order to accelerate the polishing time. Examples are discussed such as the 4 m class secondary and tertiary mirrors for the ESO E-ELT. The new equipment will enable SCHOTT to light weight 4 m class mirror substrates for future space optics demand.

  16. Motion Simulation Analysis of Rail Weld CNC Fine Milling Machine

    NASA Astrophysics Data System (ADS)

    Mao, Huajie; Shu, Min; Li, Chao; Zhang, Baojun

    CNC fine milling machine is a new advanced equipment of rail weld precision machining with high precision, high efficiency, low environmental pollution and other technical advantages. The motion performance of this machine directly affects its machining accuracy and stability, which makes it an important consideration for its design. Based on the design drawings, this article completed 3D modeling of 60mm/kg rail weld CNC fine milling machine by using Solidworks. After that, the geometry was imported into Adams to finish the motion simulation analysis. The displacement, velocity, angular velocity and some other kinematical parameters curves of the main components were obtained in the post-processing and these are the scientific basis for the design and development for this machine.

  17. High-Precision Phenotyping of Grape Bunch Architecture Using Fast 3D Sensor and Automation.

    PubMed

    Rist, Florian; Herzog, Katja; Mack, Jenny; Richter, Robert; Steinhage, Volker; Töpfer, Reinhard

    2018-03-02

    Wine growers prefer cultivars with looser bunch architecture because of the decreased risk for bunch rot. As a consequence, grapevine breeders have to select seedlings and new cultivars with regard to appropriate bunch traits. Bunch architecture is a mosaic of different single traits which makes phenotyping labor-intensive and time-consuming. In the present study, a fast and high-precision phenotyping pipeline was developed. The optical sensor Artec Spider 3D scanner (Artec 3D, L-1466, Luxembourg) was used to generate dense 3D point clouds of grapevine bunches under lab conditions and an automated analysis software called 3D-Bunch-Tool was developed to extract different single 3D bunch traits, i.e., the number of berries, berry diameter, single berry volume, total volume of berries, convex hull volume of grapes, bunch width and bunch length. The method was validated on whole bunches of different grapevine cultivars and phenotypic variable breeding material. Reliable phenotypic data were obtained which show high significant correlations (up to r² = 0.95 for berry number) compared to ground truth data. Moreover, it was shown that the Artec Spider can be used directly in the field where achieved data show comparable precision with regard to the lab application. This non-invasive and non-contact field application facilitates the first high-precision phenotyping pipeline based on 3D bunch traits in large plant sets.

  18. The use of secondary ion mass spectrometry in forensic analyses of ultra-small samples

    NASA Astrophysics Data System (ADS)

    Cliff, John

    2010-05-01

    It is becoming increasingly important in forensic science to perform chemical and isotopic analyses on very small sample sizes. Moreover, in some instances the signature of interest may be incorporated in a vast background making analyses impossible by bulk methods. Recent advances in instrumentation make secondary ion mass spectrometry (SIMS) a powerful tool to apply to these problems. As an introduction, we present three types of forensic analyses in which SIMS may be useful. The causal organism of anthrax (Bacillus anthracis) chelates Ca and other metals during spore formation. Thus, the spores contain a trace element signature related to the growth medium that produced the organisms. Although other techniques have been shown to be useful in analyzing these signatures, the sample size requirements are generally relatively large. We have shown that time of flight SIMS (TOF-SIMS) combined with multivariate analysis, can clearly separate Bacillus sp. cultures prepared in different growth media using analytical spot sizes containing approximately one nanogram of spores. An important emerging field in forensic analysis is that of provenance of fecal pollution. The strategy of choice for these analyses-developing host-specific nucleic acid probes-has met with considerable difficulty due to lack of specificity of the probes. One potentially fruitful strategy is to combine in situ nucleic acid probing with high precision isotopic analyses. Bulk analyses of human and bovine fecal bacteria, for example, indicate a relative difference in d13C content of about 4 per mil. We have shown that sample sizes of several nanograms can be analyzed with the IMS 1280 with precisions capable of separating two per mil differences in d13C. The NanoSIMS 50 is capable of much better spatial resolution than the IMS 1280, albeit at a cost of analytical precision. Nevertheless we have documented precision capable of separating five per mil differences in d13C using analytical spots containing less than 300 picograms of bacteria. Perhaps the most successful application of SIMS for forensic purposes to date is in the field of nuclear forensics. An example that has been used by laboratories associated with the International Atomic Energy Agency is the examination of environmental samples for enriched uranium particles indicative of clandestine weapons production activities.. The analytical challenge in these types of measurements is to search complex environmental matrices for U-bearing particles which must then be analyzed for 234U, 235U, and 236U content with high precision and accuracy. Older-generation SIMS instruments were hampered by small geometries that made resolution of significant interferences problematic. In addition, automated particle search software was proprietary and difficult to obtain. With the development of new search software, the IMS 1280 is capable of searching a sample in a matter of hours, flagging U-bearing particles for later analyses, and providing a rough 235U content. Particles of interest can be revisited for high precision analyses, and all U-isotopes can be measured simultaneously in multicollector mode, dramatically improving analysis time and internal precision. Further, the large geometry of the instrument allows complete resolution of isobaric interferences that have traditionally limited SIMS analyses of difficult samples. Examples of analyses of micron-sized standard particles indicate that estimates of 235U enrichment can be obtained with an external relative precision of 0.1% and 234U and 236U contents can be obtained with a relative precision of less than 1%. Analyses of 'real' samples show a dramatic improvement in the data quality obtained compared with small-geometry SIMS instruments making SIMS the method of choice for these high-profile samples when accurate, precise, and rapid results are required.

  19. Magnetic-field-induced rotation of light with orbital angular momentum

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Shi, Shuai; Ding, Dong-Sheng, E-mail: dds@ustc.edu.cn; Zhou, Zhi-Yuan

    Light carrying orbital angular momentum (OAM) has attractive applications in the fields of precise optical measurements and high capacity optical communications. We study the rotation of a light beam propagating in warm {sup 87}Rb atomic vapor using a method based on magnetic-field-induced circular birefringence. The dependence of the rotation angle on the magnetic field makes it appropriate for weak magnetic field measurements. We quote a detailed theoretical description that agrees well with the experimental observations. The experiment shown here provides a method to measure the magnetic field intensity precisely and expands the application of OAM-carrying light. This technique has advantagemore » in measurement of magnetic field weaker than 0.5 G, and the precision we achieved is 0.8 mG.« less

  20. Precision force sensing with optically-levitated nanospheres

    NASA Astrophysics Data System (ADS)

    Geraci, Andrew

    2017-04-01

    In high vacuum, optically-trapped dielectric nanospheres achieve excellent decoupling from their environment and experience minimal friction, making them ideal for precision force sensing. We have shown that 300 nm silica spheres can be used for calibrated zeptonewton force measurements in a standing-wave optical trap. In this optical potential, the known spacing of the standing wave anti-nodes can serve as an independent calibration tool for the displacement spectrum of the trapped particle. I will describe our progress towards using these sensors for tests of the Newtonian gravitational inverse square law at micron length scales. Optically levitated dielectric objects also show promise for a variety of other precision sensing applications, including searches for gravitational waves and other experiments in quantum optomechanics. National Science Foundation PHY-1205994, PHY-1506431, PHY-1509176.

  1. Freedom Is Structure.

    ERIC Educational Resources Information Center

    Papay, Twila Yates

    To make freedom work in the writing classroom, the instructor must be highly structured, possessing a clear sense of direction that includes a precise idea of the skills to be covered. Freedom refers to the view of writing as a liberal art, a liberating force with the capacity to open new channels of thought and lead students to discover…

  2. Individual Biomarkers Using Molecular Personalized Medicine Approaches.

    PubMed

    Zenner, Hans P

    2017-01-01

    Molecular personalized medicine tries to generate individual predictive biomarkers to assist doctors in their decision making. These are thought to improve the efficacy and lower the toxicity of a treatment. The molecular basis of the desired high-precision prediction is modern "omex" technologies providing high-throughput bioanalytical methods. These include genomics and epigenomics, transcriptomics, proteomics, metabolomics, microbiomics, imaging, and functional analyses. In most cases, producing big data also requires a complex biomathematical analysis. Using molecular personalized medicine, the conventional physician's check of biomarker results may no longer be sufficient. By contrast, the physician may need to cooperate with the biomathematician to achieve the desired prediction on the basis of the analysis of individual big data typically produced by omex technologies. Identification of individual biomarkers using molecular personalized medicine approaches is thought to allow a decision-making for the precise use of a targeted therapy, selecting the successful therapeutic tool from a panel of preexisting drugs or medical products. This should avoid the treatment of nonresponders and responders that produces intolerable unwanted effects. © 2017 S. Karger AG, Basel.

  3. High Precision Rovibrational Spectroscopy of OH+

    NASA Astrophysics Data System (ADS)

    Markus, Charles R.; Hodges, James N.; Perry, Adam J.; Kocheril, G. Stephen; Müller, Holger S. P.; McCall, Benjamin J.

    2016-02-01

    The molecular ion OH+ has long been known to be an important component of the interstellar medium. Its relative abundance can be used to indirectly measure cosmic ray ionization rates of hydrogen, and it is the first intermediate in the interstellar formation of water. To date, only a limited number of pure rotational transitions have been observed in the laboratory making it necessary to indirectly calculate rotational levels from high-precision rovibrational spectroscopy. We have remeasured 30 transitions in the fundamental band with MHz-level precision, in order to enable the prediction of a THz spectrum of OH+. The ions were produced in a water cooled discharge of O2, H2, and He, and the rovibrational transitions were measured with the technique Noise Immune Cavity Enhanced Optical Heterodyne Velocity Modulation Spectroscopy. These values have been included in a global fit of field free data to a 3Σ- linear molecule effective Hamiltonian to determine improved spectroscopic parameters which were used to predict the pure rotational transition frequencies.

  4. Study on digital closed-loop system of silicon resonant micro-sensor

    NASA Astrophysics Data System (ADS)

    Xu, Yefeng; He, Mengke

    2008-10-01

    Designing a micro, high reliability weak signal extracting system is a critical problem need to be solved in the application of silicon resonant micro-sensor. The closed-loop testing system based on FPGA uses software to replace hardware circuit which dramatically decrease the system's mass and power consumption and make the system more compact, both correlation theory and frequency scanning scheme are used in extracting weak signal, the adaptive frequency scanning arithmetic ensures the system real-time. The error model was analyzed to show the solution to enhance the system's measurement precision. The experiment results show that the closed-loop testing system based on FPGA has the personality of low power consumption, high precision, high-speed, real-time etc, and also the system is suitable for different kinds of Silicon Resonant Micro-sensor.

  5. High-performance time-resolved fluorescence by direct waveform recording.

    PubMed

    Muretta, Joseph M; Kyrychenko, Alexander; Ladokhin, Alexey S; Kast, David J; Gillispie, Gregory D; Thomas, David D

    2010-10-01

    We describe a high-performance time-resolved fluorescence (HPTRF) spectrometer that dramatically increases the rate at which precise and accurate subnanosecond-resolved fluorescence emission waveforms can be acquired in response to pulsed excitation. The key features of this instrument are an intense (1 μJ/pulse), high-repetition rate (10 kHz), and short (1 ns full width at half maximum) laser excitation source and a transient digitizer (0.125 ns per time point) that records a complete and accurate fluorescence decay curve for every laser pulse. For a typical fluorescent sample containing a few nanomoles of dye, a waveform with a signal/noise of about 100 can be acquired in response to a single laser pulse every 0.1 ms, at least 10(5) times faster than the conventional method of time-correlated single photon counting, with equal accuracy and precision in lifetime determination for lifetimes as short as 100 ps. Using standard single-lifetime samples, the detected signals are extremely reproducible, with waveform precision and linearity to within 1% error for single-pulse experiments. Waveforms acquired in 0.1 s (1000 pulses) with the HPTRF instrument were of sufficient precision to analyze two samples having different lifetimes, resolving minor components with high accuracy with respect to both lifetime and mole fraction. The instrument makes possible a new class of high-throughput time-resolved fluorescence experiments that should be especially powerful for biological applications, including transient kinetics, multidimensional fluorescence, and microplate formats.

  6. Developmental differences in masked form priming are not driven by vocabulary growth.

    PubMed

    Bhide, Adeetee; Schlaggar, Bradley L; Barnes, Kelly Anne

    2014-01-01

    As children develop into skilled readers, they are able to more quickly and accurately distinguish between words with similar visual forms (i.e., they develop precise lexical representations). The masked form priming lexical decision task is used to test the precision of lexical representations. In this paradigm, a prime (which differs by one letter from the target) is briefly flashed before the target is presented. Participants make a lexical decision to the target. Primes can facilitate reaction time by partially activating the lexical entry for the target. If a prime is unable to facilitate reaction time, it is assumed that participants have a precise orthographic representation of the target and thus the prime is not a close enough match to activate its lexical entry. Previous developmental work has shown that children and adults' lexical decision times are facilitated by form primes preceding words from small neighborhoods (i.e., very few words can be formed by changing one letter in the original word; low N words), but only children are facilitated by form primes preceding words from large neighborhoods (high N words). It has been hypothesized that written vocabulary growth drives the increase in the precision of the orthographic representations; children may not know all of the neighbors of the high N words, making the words effectively low N for them. We tested this hypothesis by (1) equating the effective orthographic neighborhood size of the targets for children and adults and (2) testing whether age or vocabulary size was a better predictor of the extent of form priming. We found priming differences even when controlling for effective neighborhood size. Furthermore, age was a better predictor of form priming effects than was vocabulary size. Our findings provide no support for the hypothesis that growth in written vocabulary size gives rise to more precise lexical representations. We propose that the development of spelling ability may be a more important factor.

  7. Inverse Tomo-Lithography for Making Microscopic 3D Parts

    NASA Technical Reports Server (NTRS)

    White, Victor; Wiberg, Dean

    2003-01-01

    According to a proposal, basic x-ray lithography would be extended to incorporate a technique, called inverse tomography, that would enable the fabrication of microscopic three-dimensional (3D) objects. The proposed inverse tomo-lithographic process would make it possible to produce complex shaped, submillimeter-sized parts that would be difficult or impossible to make in any other way. Examples of such shapes or parts include tapered helices, paraboloids with axes of different lengths, and even Archimedean screws that could serve as rotors in microturbines. The proposed inverse tomo-lithographic process would be based partly on a prior microfabrication process known by the German acronym LIGA (lithographie, galvanoformung, abformung, which means lithography, electroforming, molding). In LIGA, one generates a precise, high-aspect ratio pattern by exposing a thick, x-ray-sensitive resist material to an x-ray beam through a mask that contains the pattern. One can electrodeposit metal into the developed resist pattern to form a precise metal part, then dissolve the resist to free the metal. Aspect ratios of 100:1 and patterns into resist thicknesses of several millimeters are possible.

  8. Scaling up the precision in a ytterbium Bose-Einstein condensate interferometer

    NASA Astrophysics Data System (ADS)

    McAlpine, Katherine; Plotkin-Swing, Benjamin; Gochnauer, Daniel; Saxberg, Brendan; Gupta, Subhadeep

    2016-05-01

    We report on progress toward a high-precision ytterbium (Yb) Bose-Einstein condensate (BEC) interferometer, with the goal of measuring h/m and thus the fine structure constant α. Here h is Planck's constant and m is the mass of a Yb atom. The use of the non-magnetic Yb atom makes our experiment insensitive to magnetic field noise. Our chosen symmetric 3-path interferometer geometry suppresses errors from vibration, rotation, and acceleration. The precision scales with the phase accrued due to the kinetic energy difference between the interferometer arms, resulting in a quadratic sensitivity to the momentum difference. We are installing and testing the laser pulses for large momentum transfer via Bloch oscillations. We will report on Yb BEC production in a new apparatus and progress toward realizing the atom optical elements for high precision measurements. We will also discuss approaches to mitigate two important systematics: (i) atom interaction effects can be suppressed by creating the BEC in a dynamically shaped optical trap to reduce the density; (ii) diffraction phase effects from the various atom-optical elements can be accounted for through an analysis of the light-atom interaction for each pulse.

  9. The MOLLER Experiment: ``An Ultra-precise Measurement of the Weak Charge of the Electron using moller Scattering''

    NASA Astrophysics Data System (ADS)

    Beminiwattha, Rakitha; Moller Collaboration

    2017-09-01

    Parity Violating Electron Scattering (PVES) is an extremely successful precision frontier tool that has been used for testing the Standard Model (SM) and understanding nucleon structure. Several generations of highly successful PVES programs at SLAC, MIT-Bates, MAMI-Mainz, and Jefferson Lab have contributed to the understanding of nucleon structure and testing the SM. But missing phenomena like matter-antimatter asymmetry, neutrino flavor oscillations, and dark matter and energy suggest that the SM is only a `low energy' effective theory. The MOLLER experiment at Jefferson Lab will measure the weak charge of the electron, QWe = 1 - 4sin2θW , with a precision of 2.4 % by measuring the parity violating asymmetry in electron-electron () scattering and will be sensitive to subtle but measurable deviations from precisely calculable predictions from the SM. The MOLLER experiment will provide the best contact interaction search for leptons at low OR high energy makes it a probe of physics beyond the Standard Model with sensitivities to mass-scales of new PV physics up to 7.5 TeV. Overview of the experiment and recent pre-R&D progress will be reported.

  10. Self-leveling 2D DPN probe arrays

    NASA Astrophysics Data System (ADS)

    Haaheim, Jason R.; Val, Vadim; Solheim, Ed; Bussan, John; Fragala, J.; Nelson, Mike

    2010-02-01

    Dip Pen Nanolithography® (DPN®) is a direct write scanning probe-based technique which operates under ambient conditions, making it suitable to deposit a wide range of biological and inorganic materials. Precision nanoscale deposition is a fundamental requirement to advance nanoscale technology in commercial applications, and tailoring chemical composition and surface structure on the sub-100 nm scale benefits researchers in areas ranging from cell adhesion to cell-signaling and biomimetic membranes. These capabilities naturally suggest a "Desktop Nanofab" concept - a turnkey system that allows a non-expert user to rapidly create high resolution, scalable nanostructures drawing upon well-characterized ink and substrate pairings. In turn, this system is fundamentally supported by a portfolio of MEMS devices tailored for microfluidic ink delivery, directed placement of nanoscale materials, and cm2 tip arrays for high-throughput nanofabrication. Massively parallel two-dimensional nanopatterning is now commercially available via NanoInk's 2D nano PrintArray™, making DPN a high-throughput (>3×107 μm2 per hour), flexible and versatile method for precision nanoscale pattern formation. However, cm2 arrays of nanoscopic tips introduce the nontrivial problem of getting them all evenly touching the surface to ensure homogeneous deposition; this requires extremely precise leveling of the array. Herein, we describe how we have made the process simple by way of a selfleveling gimbal attachment, coupled with semi-automated software leveling routines which bring the cm^2 chip to within 0.002 degrees of co-planarity. This excellent co-planarity yields highly homogeneous features across a square centimeter, with <6% feature size standard deviation. We have engineered the devices to be easy to use, wire-free, and fully integrated with both of our patterning tools: the DPN 5000, and the NLP 2000.

  11. Progress in Measurement of Carbon Dioxide Using a Broadband Lidar

    NASA Technical Reports Server (NTRS)

    Heaps, William S.

    2010-01-01

    In order to better understand the budget of carbon dioxide in the Earth's atmosphere it is necessary to develop a global high precision understanding of the carbon dioxide column. In order to uncover the 'missing sink" that is responsible for the large discrepancies in the budget as we presently understand it calculation has indicated that measurement accuracy on the order of 1 ppm is necessary. Because typical column average CO2 has now reached 380 ppm this represents a precision on the order of .25% for these column measurements. No species has ever been measured from space at such a precision. In recognition of the importance of understanding the CO2 budget in order to evaluate its impact on global warming the National Research Council in its decadal survey report to NASA recommended planning for a laser based total CO2 mapping mission in the near future. The extreme measurement accuracy requirements on this mission places very strong requirements on the laser system used for the measurement. This work presents an overview of the characteristics necessary in a laser system used to make this measurement. Consideration is given to the temperature dependence, pressure broadening, and pressure shift of the CO2 lines themselves and how these impact the laser system characteristics We have been examining the possibility of making precise measurements of atmospheric carbon dioxide using broad band source of radiation. This means that many of the difficulties in wavelength control can be treated in the detector portion of the system rather than the laser source. It also greatly reduces the number of individual lasers required to make a measurement. Simplifications such as these are extremely desirable for systems designed to operate from space.

  12. Molecular transport through capillaries made with atomic-scale precision

    NASA Astrophysics Data System (ADS)

    Radha, B.; Esfandiar, A.; Wang, F. C.; Rooney, A. P.; Gopinadhan, K.; Keerthi, A.; Mishchenko, A.; Janardanan, A.; Blake, P.; Fumagalli, L.; Lozada-Hidalgo, M.; Garaj, S.; Haigh, S. J.; Grigorieva, I. V.; Wu, H. A.; Geim, A. K.

    2016-10-01

    Nanometre-scale pores and capillaries have long been studied because of their importance in many natural phenomena and their use in numerous applications. A more recent development is the ability to fabricate artificial capillaries with nanometre dimensions, which has enabled new research on molecular transport and led to the emergence of nanofluidics. But surface roughness in particular makes it challenging to produce capillaries with precisely controlled dimensions at this spatial scale. Here we report the fabrication of narrow and smooth capillaries through van der Waals assembly, with atomically flat sheets at the top and bottom separated by spacers made of two-dimensional crystals with a precisely controlled number of layers. We use graphene and its multilayers as archetypal two-dimensional materials to demonstrate this technology, which produces structures that can be viewed as if individual atomic planes had been removed from a bulk crystal to leave behind flat voids of a height chosen with atomic-scale precision. Water transport through the channels, ranging in height from one to several dozen atomic planes, is characterized by unexpectedly fast flow (up to 1 metre per second) that we attribute to high capillary pressures (about 1,000 bar) and large slip lengths. For channels that accommodate only a few layers of water, the flow exhibits a marked enhancement that we associate with an increased structural order in nanoconfined water. Our work opens up an avenue to making capillaries and cavities with sizes tunable to ångström precision, and with permeation properties further controlled through a wide choice of atomically flat materials available for channel walls.

  13. Precision medicine needs pioneering clinical bioinformaticians.

    PubMed

    Gómez-López, Gonzalo; Dopazo, Joaquín; Cigudosa, Juan C; Valencia, Alfonso; Al-Shahrour, Fátima

    2017-10-25

    Success in precision medicine depends on accessing high-quality genetic and molecular data from large, well-annotated patient cohorts that couple biological samples to comprehensive clinical data, which in conjunction can lead to effective therapies. From such a scenario emerges the need for a new professional profile, an expert bioinformatician with training in clinical areas who can make sense of multi-omics data to improve therapeutic interventions in patients, and the design of optimized basket trials. In this review, we first describe the main policies and international initiatives that focus on precision medicine. Secondly, we review the currently ongoing clinical trials in precision medicine, introducing the concept of 'precision bioinformatics', and we describe current pioneering bioinformatics efforts aimed at implementing tools and computational infrastructures for precision medicine in health institutions around the world. Thirdly, we discuss the challenges related to the clinical training of bioinformaticians, and the urgent need for computational specialists capable of assimilating medical terminologies and protocols to address real clinical questions. We also propose some skills required to carry out common tasks in clinical bioinformatics and some tips for emergent groups. Finally, we explore the future perspectives and the challenges faced by precision medicine bioinformatics. © The Author 2017. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

  14. From technological advances to biological understanding: The main steps toward high-precision RT in breast cancer.

    PubMed

    Leonardi, Maria Cristina; Ricotti, Rosalinda; Dicuonzo, Samantha; Cattani, Federica; Morra, Anna; Dell'Acqua, Veronica; Orecchia, Roberto; Jereczek-Fossa, Barbara Alicja

    2016-10-01

    Radiotherapy improves local control in breast cancer (BC) patients which increases overall survival in the long term. Improvements in treatment planning and delivery and a greater understanding of BC behaviour have laid the groundwork for high-precision radiotherapy, which is bound to further improve the therapeutic index. Precise identification of target volumes, better coverage and dose homogeneity have had a positive impact on toxicity and local control. The conformity of treatment dose due to three-dimensional radiotherapy and new techniques such as intensity modulated radiotherapy makes it possible to spare surrounding normal tissue. The widespread use of dose-volume constraints and histograms have increased awareness of toxicity. Real time image guidance has improved geometric precision and accuracy, together with the implementation of quality assurance programs. Advances in the precision of radiotherapy is also based on the choice of the appropriate fractionation and approach. Adaptive radiotherapy is not only a technical concept, but is also a biological concept based on the knowledge that different types of BC have distinctive patterns of locoregional spread. A greater understanding of cancer biology helps in choosing the treatment best suited to a particular situation. Biomarkers predictive of response play a crucial role. The combination of radiotherapy with molecular targeted therapies may enhance radiosensitivity, thus increasing the cytotoxic effects and improving treatment response. The appropriateness of an alternative fractionation, partial breast irradiation, dose escalating/de-escalating approaches, the extent of nodal irradiation have been examined for all the BC subtypes. The broadened concept of adaptive radiotherapy is vital to high-precision treatments. Copyright © 2016 Elsevier Ltd. All rights reserved.

  15. Validating data analysis of broadband laser ranging

    NASA Astrophysics Data System (ADS)

    Rhodes, M.; Catenacci, J.; Howard, M.; La Lone, B.; Kostinski, N.; Perry, D.; Bennett, C.; Patterson, J.

    2018-03-01

    Broadband laser ranging combines spectral interferometry and a dispersive Fourier transform to achieve high-repetition-rate measurements of the position of a moving surface. Telecommunications fiber is a convenient tool for generating the large linear dispersions required for a dispersive Fourier transform, but standard fiber also has higher-order dispersion that distorts the Fourier transform. Imperfections in the dispersive Fourier transform significantly complicate the ranging signal and must be dealt with to make high-precision measurements. We describe in detail an analysis process for interpreting ranging data when standard telecommunications fiber is used to perform an imperfect dispersive Fourier transform. This analysis process is experimentally validated over a 27-cm scan of static positions, showing an accuracy of 50 μm and a root-mean-square precision of 4.7 μm.

  16. A multichannel fiber optic photometer present performance and future developments

    NASA Technical Reports Server (NTRS)

    Barwig, H.; Schoembs, R.; Huber, G.

    1988-01-01

    A three channel photometer for simultaneous multicolor observations was designed with the aim of making possible highly efficient photometry of fast variable objects like cataclysmic variables. Experiences with this instrument over a period of three years are presented. Aspects of the special techniques applied are discussed with respect to high precision photometry. In particular, the use of fiber optics is critically analyzed. Finally, the development of a new photometer concept is discussed.

  17. Precision medicine in breast cancer: reality or utopia?

    PubMed

    Bettaieb, Ali; Paul, Catherine; Plenchette, Stéphanie; Shan, Jingxuan; Chouchane, Lotfi; Ghiringhelli, François

    2017-06-17

    Many cancers, including breast cancer, have demonstrated prognosis and support advantages thanks to the discovery of targeted therapies. The advent of these new approaches marked the rise of precision medicine, which leads to improve the diagnosis, prognosis and treatment of cancer. Precision medicine takes into account the molecular and biological specificities of the patient and their tumors that will influence the treatment determined by physicians. This new era of medicine is accessible through molecular genetics platforms, the development of high-speed sequencers and means of analysis of these data. Despite the spectacular results in the treatment of cancers including breast cancer, described in this review, not all patients however can benefit from this new strategy. This seems to be related to the many genetic mutations, which may be different from one patient to another or within the same patient. It comes to give new impetus to the research-both from a technological and biological point of view-to make the hope of precision medicine accessible to all.

  18. Bringing Definitions into High Definition

    ERIC Educational Resources Information Center

    Mason, John

    2010-01-01

    Why do definitions play such a central role in mathematics? It may seem obvious that precision about the terms one uses is necessary in order to use those terms reasonably (while reasoning). Definitions are chosen so as to be definite about the terms one uses, but also to make both the statement of, and the reasoning to justify, theorems as…

  19. Precision timing measurements of PSR J1012+5307

    NASA Astrophysics Data System (ADS)

    Lange, Ch.; Camilo, F.; Wex, N.; Kramer, M.; Backer, D. C.; Lyne, A. G.; Doroshenko, O.

    2001-09-01

    We present results and applications of high-precision timing measurements of the binary millisecond pulsar J1012+5307. Combining our radio timing measurements with results based on optical observations, we derive complete 3D velocity information for this system. Correcting for Doppler effects, we derive the intrinsic spin parameters of this pulsar and a characteristic age of 8.6+/-1.9Gyr. Our upper limit for the orbital eccentricity of only 8×10-7 (68 per cent confidence level) is the smallest ever measured for a binary system. We demonstrate that this makes the pulsar an ideal laboratory in which to test certain aspects of alternative theories of gravitation. Our precision measurements suggest deviations from a simple pulsar spin-down timing model, which are consistent with timing noise and the extrapolation of the known behaviour of slowly rotating pulsars.

  20. Data and Time Transfer Using SONET Radio

    NASA Technical Reports Server (NTRS)

    Graceffo, Gary M.

    1996-01-01

    The need for precise knowledge of time and frequency has become ubiquitous throughout our society. The areas of astronomy, navigation, and high speed wide-area networks are among a few of the many consumers of this type of information. The Global Positioning System (GPS) has the potential to be the most comprehensive source of precise timing information developed to date; however, the introduction of selective availability has made it difficult for many users to recover this information from the GPS system with the precision required for today's systems. The system described in this paper is a 'Synchronous Optical NetWORK (SONET) Radio Data and Time Transfer System'. The objective of this system is to provide precise time and frequency information to a variety of end-users using a two-way data and time-transfer system. Although time and frequency transfers have been done for many years, this system is unique in that time and frequency information are embedded into existing communications traffic. This eliminates the need to make the transfer of time and frequency informatio a dedicated function of the communications system. For this system SONET has been selected as the transport format from which precise time is derived. SONET has been selected because of its high data rates and its increasing acceptance throughout the industry. This paper details a proof-of-concept initiative to perform embedded time and frequency transfers using SONET Radio.

  1. The influence of number line estimation precision and numeracy on risky financial decision making.

    PubMed

    Park, Inkyung; Cho, Soohyun

    2018-01-10

    This study examined whether different aspects of mathematical proficiency influence one's ability to make adaptive financial decisions. "Numeracy" refers to the ability to process numerical and probabilistic information and is commonly reported as an important factor which contributes to financial decision-making ability. The precision of mental number representation (MNR), measured with the number line estimation (NLE) task has been reported to be another critical factor. This study aimed to examine the contribution of these mathematical proficiencies while controlling for the influence of fluid intelligence, math anxiety and personality factors. In our decision-making task, participants chose between two options offering probabilistic monetary gain or loss. Sensitivity to expected value was measured as an index for the ability to discriminate between optimal versus suboptimal options. Partial correlation and hierarchical regression analyses revealed that NLE precision better explained EV sensitivity compared to numeracy, after controlling for all covariates. These results suggest that individuals with more precise MNR are capable of making more rational financial decisions. We also propose that the measurement of "numeracy," which is commonly used interchangeably with general mathematical proficiency, should include more diverse aspects of mathematical cognition including basic understanding of number magnitude. © 2018 International Union of Psychological Science.

  2. Calibration of gyro G-sensitivity coefficients with FOG monitoring on precision centrifuge

    NASA Astrophysics Data System (ADS)

    Lu, Jiazhen; Yang, Yanqiang; Li, Baoguo; Liu, Ming

    2017-07-01

    The advantages of mechanical gyros, such as high precision, endurance and reliability, make them widely used as the core parts of inertial navigation systems (INS) utilized in the fields of aeronautics, astronautics and underground exploration. In a high-g environment, the accuracy of gyros is degraded. Therefore, the calibration and compensation of the gyro G-sensitivity coefficients is essential when the INS operates in a high-g environment. A precision centrifuge with a counter-rotating platform is the typical equipment for calibrating the gyro, as it can generate large centripetal acceleration and keep the angular rate close to zero; however, its performance is seriously restricted by the angular perturbation in the high-speed rotating process. To reduce the dependence on the precision of the centrifuge and counter-rotating platform, an effective calibration method for the gyro g-sensitivity coefficients under fiber-optic gyroscope (FOG) monitoring is proposed herein. The FOG can efficiently compensate spindle error and improve the anti-interference ability. Harmonic analysis is performed for data processing. Simulations show that the gyro G-sensitivity coefficients can be efficiently estimated to up to 99% of the true value and compensated using a lookup table or fitting method. Repeated tests indicate that the G-sensitivity coefficients can be correctly calibrated when the angular rate accuracy of the precision centrifuge is as low as 0.01%. Verification tests are performed to demonstrate that the attitude errors can be decreased from 0.36° to 0.08° in 200 s. The proposed measuring technology is generally applicable in engineering, as it can reduce the accuracy requirements for the centrifuge and the environment.

  3. Rapid Prototyping Technology for Manufacturing GTE Turbine Blades

    NASA Astrophysics Data System (ADS)

    Balyakin, A. V.; Dobryshkina, E. M.; Vdovin, R. A.; Alekseev, V. P.

    2018-03-01

    The conventional approach to manufacturing turbine blades by investment casting is expensive and time-consuming, as it takes a lot of time to make geometrically precise and complex wax patterns. Turbine blade manufacturing in pilot production can be sped up by accelerating the casting process while keeping the geometric precision of the final product. This paper compares the rapid prototyping method (casting the wax pattern composition into elastic silicone molds) to the conventional technology. Analysis of the size precision of blade casts shows that silicon-mold casting features sufficient geometric precision. Thus, this method for making wax patterns can be a cost-efficient solution for small-batch or pilot production of turbine blades for gas-turbine units (GTU) and gas-turbine engines (GTE). The paper demonstrates how additive technology and thermographic analysis can speed up the cooling of wax patterns in silicone molds. This is possible at an optimal temperature and solidification time, which make the process more cost-efficient while keeping the geometric quality of the final product.

  4. The Gigatracker: An ultra-fast and low-mass silicon pixel detector for the NA62 experiment

    NASA Astrophysics Data System (ADS)

    Fiorini, M.; Carassiti, V.; Ceccucci, A.; Cortina, E.; Cotta Ramusino, A.; Dellacasa, G.; Garbolino, S.; Jarron, P.; Kaplon, J.; Kluge, A.; Mapelli, A.; Marchetto, F.; Martin, E.; Martoiu, S.; Mazza, G.; Morel, M.; Noy, M.; Nuessle, G.; Petrucci, F.; Riedler, P.; Aglieri Rinella, G.; Rivetti, A.; Tiuraniemi, S.

    2011-02-01

    The Gigatracker is a hybrid silicon pixel detector developed to track the highly intense NA62 hadron beam with a time resolution of 150 ps (rms). The beam spectrometer of the experiment is composed of three Gigatracker stations installed in vacuum in order to precisely measure momentum, time and direction of every traversing particle. Precise tracking demands a very low mass of the detector assembly ( <0.5% X0 per station) in order to limit multiple scattering and beam hadronic interactions. The high rate and especially the high timing precision requirements are very demanding: two R&D options are ongoing and the corresponding prototype read-out chips have been recently designed and produced in 0.13 μm CMOS technology. One solution makes use of a constant fraction discriminator and on-pixel analogue-based time-to-digital-converter (TDC); the other comprises a delay-locked loop based TDC placed at the end of each pixel column and a time-over-threshold discriminator with time-walk correction technique. The current status of the R&D program is overviewed and results from the prototype read-out chips test are presented.

  5. The Orbiter camera payload system's large-format camera and attitude reference system

    NASA Technical Reports Server (NTRS)

    Schardt, B. B.; Mollberg, B. H.

    1985-01-01

    The Orbiter camera payload system (OCPS) is an integrated photographic system carried into earth orbit as a payload in the Space Transportation System (STS) Orbiter vehicle's cargo bay. The major component of the OCPS is a large-format camera (LFC), a precision wide-angle cartographic instrument capable of producing high-resolution stereophotography of great geometric fidelity in multiple base-to-height ratios. A secondary and supporting system to the LFC is the attitude reference system (ARS), a dual-lens stellar camera array (SCA) and camera support structure. The SCA is a 70 mm film system that is rigidly mounted to the LFC lens support structure and, through the simultaneous acquisition of two star fields with each earth viewing LFC frame, makes it possible to precisely determine the pointing of the LFC optical axis with reference to the earth nadir point. Other components complete the current OCPS configuration as a high-precision cartographic data acquisition system. The primary design objective for the OCPS was to maximize system performance characteristics while maintaining a high level of reliability compatible with rocket launch conditions and the on-orbit environment. The full OCPS configuration was launched on a highly successful maiden voyage aboard the STS Orbiter vehicle Challenger on Oct. 5, 1984, as a major payload aboard the STS-41G mission.

  6. [The equivalence and interchangeability of medical articles].

    PubMed

    Antonov, V S

    2013-11-01

    The information concerning the interchangeability of medical articles is highly valuable because it makes it possible to correlate most precisely medical articles with medical technologies and medical care standards and to optimize budget costs under public purchasing. The proposed procedure of determination of interchangeability is based on criteria of equivalence of prescriptions, functional technical and technological characteristics and effectiveness of functioning of medical articles.

  7. KSC-2012-6430

    NASA Image and Video Library

    2012-12-05

    CAPE CANAVERAL, Fla. – Technicians prepare to lift a special fixture inside the high bay of the Operations & Checkout Building at NASA's Kennedy Space Center in Florida. The fixture is designed to enable precise pre-launch processing of the Orion spacecraft. An Orion capsule is being prepared to make a flight test in 2014 on a mission that will not carry any astronauts. Photo by Tim Jacobs

  8. KSC-2012-6447

    NASA Image and Video Library

    2012-12-06

    CAPE CANAVERAL, Fla. – Technicians lift a special fixture inside the high bay of the Operations & Checkout Building at NASA's Kennedy Space Center in Florida. The fixture is designed to enable precise pre-launch processing of the Orion spacecraft. An Orion capsule is being prepared to make a flight test in 2014 on a mission that will not carry any astronauts. Photo by Tim Jacobs

  9. KSC-2012-6428

    NASA Image and Video Library

    2012-12-05

    CAPE CANAVERAL, Fla. – Technicians prepare to lift a special fixture inside the high bay of the Operations & Checkout Building at NASA's Kennedy Space Center in Florida. The fixture is designed to enable precise pre-launch processing of the Orion spacecraft. An Orion capsule is being prepared to make a flight test in 2014 on a mission that will not carry any astronauts. Photo by Tim Jacobs

  10. KSC-2012-6429

    NASA Image and Video Library

    2012-12-05

    CAPE CANAVERAL, Fla. – Technicians prepare to lift a special fixture inside the high bay of the Operations & Checkout Building at NASA's Kennedy Space Center in Florida. The fixture is designed to enable precise pre-launch processing of the Orion spacecraft. An Orion capsule is being prepared to make a flight test in 2014 on a mission that will not carry any astronauts. Photo by Tim Jacobs

  11. KSC-2012-6446

    NASA Image and Video Library

    2012-12-06

    CAPE CANAVERAL, Fla. – Technicians lift a special fixture inside the high bay of the Operations & Checkout Building at NASA's Kennedy Space Center in Florida. The fixture is designed to enable precise pre-launch processing of the Orion spacecraft. An Orion capsule is being prepared to make a flight test in 2014 on a mission that will not carry any astronauts. Photo by Tim Jacobs

  12. KSC-2012-6445

    NASA Image and Video Library

    2012-12-05

    CAPE CANAVERAL, Fla. – Technicians lift a special fixture inside the high bay of the Operations & Checkout Building at NASA's Kennedy Space Center in Florida. The fixture is designed to enable precise pre-launch processing of the Orion spacecraft. An Orion capsule is being prepared to make a flight test in 2014 on a mission that will not carry any astronauts. Photo by Tim Jacobs

  13. Universal Tool Grinder Operator Instructor's Guide. Part of Single-Tool Skills Program Machine Industries Occupations.

    ERIC Educational Resources Information Center

    New York State Education Dept., Albany. Div. of Curriculum Development.

    The document is an instructor's guide for a course on universal tool grinder operation. The course is designed to train people in making complicated machine setups and precision in the grinding operations and, although intended primarily for adult learners, it can be adapted for high school use. The guide is divided into three parts: (1) the…

  14. Reliable Location-Based Services from Radio Navigation Systems

    PubMed Central

    Qiu, Di; Boneh, Dan; Lo, Sherman; Enge, Per

    2010-01-01

    Loran is a radio-based navigation system originally designed for naval applications. We show that Loran-C’s high-power and high repeatable accuracy are fantastic for security applications. First, we show how to derive a precise location tag—with a sensitivity of about 20 meters—that is difficult to project to an exact location. A device can use our location tag to block or allow certain actions, without knowing its precise location. To ensure that our tag is reproducible we make use of fuzzy extractors, a mechanism originally designed for biometric authentication. We build a fuzzy extractor specifically designed for radio-type errors and give experimental evidence to show its effectiveness. Second, we show that our location tag is difficult to predict from a distance. For example, an observer cannot predict the location tag inside a guarded data center from a few hundreds of meters away. As an application, consider a location-aware disk drive that will only work inside the data center. An attacker who steals the device and is capable of spoofing Loran-C signals, still cannot make the device work since he does not know what location tag to spoof. We provide experimental data supporting our unpredictability claim. PMID:22163532

  15. Reliable location-based services from radio navigation systems.

    PubMed

    Qiu, Di; Boneh, Dan; Lo, Sherman; Enge, Per

    2010-01-01

    Loran is a radio-based navigation system originally designed for naval applications. We show that Loran-C's high-power and high repeatable accuracy are fantastic for security applications. First, we show how to derive a precise location tag--with a sensitivity of about 20 meters--that is difficult to project to an exact location. A device can use our location tag to block or allow certain actions, without knowing its precise location. To ensure that our tag is reproducible we make use of fuzzy extractors, a mechanism originally designed for biometric authentication. We build a fuzzy extractor specifically designed for radio-type errors and give experimental evidence to show its effectiveness. Second, we show that our location tag is difficult to predict from a distance. For example, an observer cannot predict the location tag inside a guarded data center from a few hundreds of meters away. As an application, consider a location-aware disk drive that will only work inside the data center. An attacker who steals the device and is capable of spoofing Loran-C signals, still cannot make the device work since he does not know what location tag to spoof. We provide experimental data supporting our unpredictability claim.

  16. Precision Branching Ratio Measurement for the Superallowed &+circ; Emitter ^62Ga

    NASA Astrophysics Data System (ADS)

    Finlay, Paul; Svensson, C. E.; Austin, R. A. E.; Ball, G. C.; Bandyopadhyay, D.; Chaffey, A.; Chakrawarthy, R. S.; Garrett, P. E.; Grinyer, G. F.; Hackman, G.; Hyland, B.; Kanungo, R.; Leslie, J. R.; Mattoon, C.; Morton, A. C.; Pearson, C. J.; Ressler, J. J.; Sarazin, F.; Savajols, H.

    2007-10-01

    A high-precision branching ratio measurement for the superallowed &+circ; emitter ^62Ga has been made using the 8π γ-ray spectrometer in conjunction with the SCintillating Electron-Positron Tagging ARray (SCEPTAR) as part of an ongoing experimental program in superallowed Fermi beta decay studies at the Isotope Separator and Accelerator (ISAC) facility at TRIUMF in Vancouver, Canada, which delivered a high-purity beam of ˜10^4 ^62Ga/s in December 2005. The present work represents the highest statistics measurement of the ^62Ga superallowed branching ratio to date. 25 γ rays emitted following non-superallowed decay branches of ^62Ga have been identified and their intensities determined. These data yield a superallowed branching ratio with 10-4 precision, and our observed branch to the first nonanalogue 0^+ state sets a new upper limit on the isospin-mixing correction δC1^1. By comparing our ft value with the world average Ft, we make stringent tests of the different calculations for the isospin-symmetry-breaking correction δC, which is predicted to be large for ^62Ga.

  17. High-precision measurements of wetland sediment elevation. I. Recent improvements to the sedimentation--erosion table

    USGS Publications Warehouse

    Cahoon, D.R.; Lynch, J.C.; Hensel, P.; Boumans, R.; Perez, B.C.; Segura, B.; Day, J.W.

    2002-01-01

    The sedimentation-erosion table (SET) developed by Boumans and Day (1993) is herein renamed the surface elevation table (SET) to better reflect the conceptual view of the processes being measured. The SET was designed for making high-resolution measurements of small-scale changes in elevation of loose, unconsolidated sediments in shallow water and mudflat habitats. The SET has undergone three major improvements to increase precision and so that it can be used to measure sediment elevation in vegetated wetlands as well as shallow water habitats. The remote-release 'sliding plate' mechanism has been replaced with a single plate, collars (first 2.5 cm then 7.5 cm in length) have been attached to the plate to reduce play in the placement of the measuring pins, and the brass measuring pins have been replaced with fiberglass pins to reduce bending and consequent loss of precision. Under ideal laboratory conditions, the 95% confidence limit for individual pin measurements averaged about A? 1.4 mm (range A? 0.7 to A? 1.9 mm). These modifications have resulted in a reduction of error by about 50%.

  18. High-precision measurement of variations in calcium isotope ratios in urine by multiple collector inductively coupled plasma mass spectrometry

    USGS Publications Warehouse

    Morgan, J.L.L.; Gordon, G.W.; Arrua, R.C.; Skulan, J.L.; Anbar, A.D.; Bullen, T.D.

    2011-01-01

    We describe a new chemical separation method to isolate Ca from other matrix elements in biological samples, developed with the long-term goal of making high-precision measurement of natural stable Ca isotope variations a clinically applicable tool to assess bone mineral balance. A new two-column procedure utilizing HBr achieves the purity required to accurately and precisely measure two Ca isotope ratios (44Ca/42Ca and 44Ca/43Ca) on a Neptune multiple collector inductively coupled plasma mass spectrometer (MC-ICPMS) in urine. Purification requirements for Sr, Ti, and K (Ca/Sr > 10000; Ca/Ti > 10000000; and Ca/K > 10) were determined by addition of these elements to Ca standards of known isotopic composition. Accuracy was determined by (1) comparing Ca isotope results for samples and standards to published data obtained using thermal ionization mass spectrometry (TIMS), (2) adding a Ca standard of known isotopic composition to a urine sample purified of Ca, and (3) analyzing mixtures of urine samples and standards in varying proportions. The accuracy and precision of δ44/42Ca measurements of purified samples containing 25 μg of Ca can be determined with typical errors less than ±0.2‰ (2σ).

  19. Conjugating precision and acquisition time in a Doppler broadening regime by interleaved frequency-agile rapid-scanning cavity ring-down spectroscopy.

    PubMed

    Gotti, Riccardo; Gatti, Davide; Masłowski, Piotr; Lamperti, Marco; Belmonte, Michele; Laporta, Paolo; Marangoni, Marco

    2017-10-07

    We propose a novel approach to cavity-ring-down-spectroscopy (CRDS) in which spectra acquired with a frequency-agile rapid-scanning (FARS) scheme, i.e., with a laser sideband stepped across the modes of a high-finesse cavity, are interleaved with one another by a sub-millisecond readjustment of the cavity length. This brings to time acquisitions below 20 s for few-GHz-wide spectra composed of a very high number of spectral points, typically 3200. Thanks to the signal-to-noise ratio easily in excess of 10 000, each FARS-CRDS spectrum is shown to be sufficient to determine the line-centre frequency of a Doppler broadened line with a precision of 2 parts over 10 11 , thus very close to that of sub-Doppler regimes and in a few-seconds time scale. The referencing of the probe laser to a frequency comb provides absolute accuracy and long-term reproducibility to the spectrometer and makes it a powerful tool for precision spectroscopy and line-shape analysis. The experimental approach is discussed in detail together with experimental precision and accuracy tests on the (30 012) ← (00 001) P12e line of CO 2 at ∼1.57 μm.

  20. Principles of precision medicine in stroke.

    PubMed

    Hinman, Jason D; Rost, Natalia S; Leung, Thomas W; Montaner, Joan; Muir, Keith W; Brown, Scott; Arenillas, Juan F; Feldmann, Edward; Liebeskind, David S

    2017-01-01

    The era of precision medicine has arrived and conveys tremendous potential, particularly for stroke neurology. The diagnosis of stroke, its underlying aetiology, theranostic strategies, recurrence risk and path to recovery are populated by a series of highly individualised questions. Moreover, the phenotypic complexity of a clinical diagnosis of stroke makes a simple genetic risk assessment only partially informative on an individual basis. The guiding principles of precision medicine in stroke underscore the need to identify, value, organise and analyse the multitude of variables obtained from each individual to generate a precise approach to optimise cerebrovascular health. Existing data may be leveraged with novel technologies, informatics and practical clinical paradigms to apply these principles in stroke and realise the promise of precision medicine. Importantly, precision medicine in stroke will only be realised once efforts to collect, value and synthesise the wealth of data collected in clinical trials and routine care starts. Stroke theranostics, the ultimate vision of synchronising tailored therapeutic strategies based on specific diagnostic data, demand cerebrovascular expertise on big data approaches to clinically relevant paradigms. This review considers such challenges and delineates the principles on a roadmap for rational application of precision medicine to stroke and cerebrovascular health. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://www.bmj.com/company/products-services/rights-and-licensing/.

  1. High-precision measurement of phenylalanine δ15N values for environmental samples: a new approach coupling high-pressure liquid chromatography purification and elemental analyzer isotope ratio mass spectrometry.

    PubMed

    Broek, Taylor A B; Walker, Brett D; Andreasen, Dyke H; McCarthy, Matthew D

    2013-11-15

    Compound-specific isotope analysis of individual amino acids (CSI-AA) is a powerful new tool for tracing nitrogen (N) source and transformation in biogeochemical cycles. Specifically, the δ(15)N value of phenylalanine (δ(15)N(Phe)) represents an increasingly used proxy for source δ(15)N signatures, with particular promise for paleoceanographic applications. However, current derivatization/gas chromatography methods require expensive and relatively uncommon instrumentation, and have relatively low precision, making many potential applications impractical. A new offline approach has been developed for high-precision δ(15)N measurements of amino acids (δ(15)N(AA)), optimized for δ(15)N(Phe) values. Amino acids (AAs) are first purified via high-pressure liquid chromatography (HPLC), using a mixed-phase column and automated fraction collection. The δ(15)N values are determined via offline elemental analyzer-isotope ratio mass spectrometry (EA-IRMS). The combined HPLC/EA-IRMS method separated most protein AAs with sufficient resolution to obtain accurate δ(15)N values, despite significant intra-peak isotopic fractionation. For δ(15)N(Phe) values, the precision was ±0.16‰ for standards, 4× better than gas chromatography/combustion/isotope ratio mass spectrometry (GC/C/IRMS; ±0.64‰). We also compared a δ(15)N(Phe) paleo-record from a deep-sea bamboo coral from Monterey Bay, CA, USA, using our method versus GC/C/IRMS. The two methods produced equivalent δ(15)N(Phe) values within error; however, the δ(15)N(Phe) values from HPLC/EA-IRMS had approximately twice the precision of GC/C/IRMS (average stdev of 0.27‰ ± 0.14‰ vs 0.60‰ ± 0.20‰, respectively). These results demonstrate that offline HPLC represents a viable alternative to traditional GC/C/IMRS for δ(15)N(AA) measurement. HPLC/EA-IRMS is more precise and widely available, and therefore useful in applications requiring increased precision for data interpretation (e.g. δ(15)N paleoproxies). Copyright © 2013 John Wiley & Sons, Ltd.

  2. Segmented Detector Calibration Techniques for the PROSPECT Experiment

    NASA Astrophysics Data System (ADS)

    Davee, Daniel; Prospect Collaboration

    2016-03-01

    PROSPECT will make the most precise measurement of the 235U anti-neutrino spectrum to date and search for eV-scale sterile neutrinos. The proposed detector is composed of 120 6Li loaded liquid scintillator filled cells, and uses Inverse Beta Decay (IBD) ν + p -->e+ + n to detect reactor anti-neutrinos. Because the positron produced in IBD carries most of the ν energy, the response throughout the entire segmented detector to electron-like energy depositions must be determined with high precision via an extensive calibration program. To this end the detector is designed to allow for the insertion of both optical and radioactive sources to test each performance of cell individually without changing the optical response. In addition to these measures, cosmogenic sources will be used to probe energy response of the detector at high energies.

  3. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Sun, Rongyu; Zhao, Changyin; Zhang, Xiaoxiang, E-mail: cyzhao@pmo.ac.cn

    The data reduction method for optical space debris observations has many similarities with the one adopted for surveying near-Earth objects; however, due to several specific issues, the image degradation is particularly critical, which makes it difficult to obtain precise astrometry. An automatic image reconstruction method was developed to improve the astrometry precision for space debris, based on the mathematical morphology operator. Variable structural elements along multiple directions are adopted for image transformation, and then all the resultant images are stacked to obtain a final result. To investigate its efficiency, trial observations are made with Global Positioning System satellites and themore » astrometry accuracy improvement is obtained by comparison with the reference positions. The results of our experiments indicate that the influence of degradation in astrometric CCD images is reduced, and the position accuracy of both objects and stellar stars is improved distinctly. Our technique will contribute significantly to optical data reduction and high-order precision astrometry for space debris.« less

  4. Latest results from Daya Bay

    NASA Astrophysics Data System (ADS)

    Vorobel, Vit; Daya Bay Collaboration

    2017-07-01

    The Daya Bay Reactor Neutrino Experiment was designed to measure θ 13, the smallest mixing angle in the three-neutrino mixing framework, with unprecedented precision. The experiment consists of eight functionally identical detectors placed underground at different baselines from three pairs of nuclear reactors in South China. Since Dec. 2011, the experiment has been running stably for more than 4 years, and has collected the largest reactor anti-neutrino sample to date. Daya Bay is able to greatly improve the precision on θ 13 and to make an independent measurement of the effective mass splitting in the electron antineutrino disappearance channel. Daya Bay can also perform a number of other precise measurements, such as a high-statistics determination of the absolute reactor antineutrino flux and spectrum, as well as a search for sterile neutrino mixing, among others. The most recent results from Daya Bay are discussed in this paper, as well as the current status and future prospects of the experiment.

  5. A method of undifferenced ambiguity resolution for GPS+GLONASS precise point positioning

    PubMed Central

    Yi, Wenting; Song, Weiwei; Lou, Yidong; Shi, Chuang; Yao, Yibin

    2016-01-01

    Integer ambiguity resolution is critical for achieving positions of high precision and for shortening the convergence time of precise point positioning (PPP). However, GLONASS adopts the signal processing technology of frequency division multiple access and results in inter-frequency code biases (IFCBs), which are currently difficult to correct. This bias makes the methods proposed for GPS ambiguity fixing unsuitable for GLONASS. To realize undifferenced GLONASS ambiguity fixing, we propose an undifferenced ambiguity resolution method for GPS+GLONASS PPP, which considers the IFCBs estimation. The experimental result demonstrates that the success rate of GLONASS ambiguity fixing can reach 75% through the proposed method. Compared with the ambiguity float solutions, the positioning accuracies of ambiguity-fixed solutions of GLONASS-only PPP are increased by 12.2%, 20.9%, and 10.3%, and that of the GPS+GLONASS PPP by 13.0%, 35.2%, and 14.1% in the North, East and Up directions, respectively. PMID:27222361

  6. A method of undifferenced ambiguity resolution for GPS+GLONASS precise point positioning.

    PubMed

    Yi, Wenting; Song, Weiwei; Lou, Yidong; Shi, Chuang; Yao, Yibin

    2016-05-25

    Integer ambiguity resolution is critical for achieving positions of high precision and for shortening the convergence time of precise point positioning (PPP). However, GLONASS adopts the signal processing technology of frequency division multiple access and results in inter-frequency code biases (IFCBs), which are currently difficult to correct. This bias makes the methods proposed for GPS ambiguity fixing unsuitable for GLONASS. To realize undifferenced GLONASS ambiguity fixing, we propose an undifferenced ambiguity resolution method for GPS+GLONASS PPP, which considers the IFCBs estimation. The experimental result demonstrates that the success rate of GLONASS ambiguity fixing can reach 75% through the proposed method. Compared with the ambiguity float solutions, the positioning accuracies of ambiguity-fixed solutions of GLONASS-only PPP are increased by 12.2%, 20.9%, and 10.3%, and that of the GPS+GLONASS PPP by 13.0%, 35.2%, and 14.1% in the North, East and Up directions, respectively.

  7. A precision device needs precise simulation: Software description of the CBM Silicon Tracking System

    NASA Astrophysics Data System (ADS)

    Malygina, Hanna; Friese, Volker; CBM Collaboration

    2017-10-01

    Precise modelling of detectors in simulations is the key to the understanding of their performance, which, in turn, is a prerequisite for the proper design choice and, later, for the achievement of valid physics results. In this report, we describe the implementation of the Silicon Tracking System (STS), the main tracking device of the CBM experiment, in the CBM software environment. The STS makes uses of double-sided silicon micro-strip sensors with double metal layers. We present a description of transport and detector response simulation, including all relevant physical effects like charge creation and drift, charge collection, cross-talk and digitization. Of particular importance and novelty is the description of the time behaviour of the detector, since its readout will not be externally triggered but continuous. We also cover some aspects of local reconstruction, which in the CBM case has to be performed in real-time and thus requires high-speed algorithms.

  8. [Calm thinking for precision medicine of breast cancer in the boom].

    PubMed

    Jiang, Z F; Xu, F R

    2017-02-01

    In the past two years, researchers have been exploring the precision medicine. Thanks to the development of sequence industry and clinical study, the big data about the precision medicine have been more and more sufficient. However, how to deal with the precision data is still a question for clinicians. We focus on the hot issues that disturb clinicians most, wanting to help them to make suitable decisions between the traditional and precision medicine of breast cancer. We believe the precision medicine is on the way.

  9. Amplion, Inc.

    PubMed

    Taylor, Seth; Carroll, Adam; Lord, Jessi

    2016-07-01

    Amplion, Inc. (OR, USA) is focused on progressing the primary drivers of precision medicine. Focused on enabling the front end of the healthcare value chain, pharmaceutical developers and diagnostic test developers, Amplion zeros in on the research and market components that will make precision medicine a reality. With BiomarkerBase™, Amplion's flagship product, Amplion provides evidence-based biomarker information that support the key strategic decisions pharmaceutical and diagnostic developers need to make to be successful in the emerging world of precision medicine. A passion for saving lives and improving patient outcomes using precision medicine inspires Amplion's product BiomarkerBase™. A unique combination of hard science and data science positions Amplion to surface the relationships of biomarkers and clinical evidence that gives pharmaceutical and diagnostic companies unique insight into the technical realities and market opportunities provided by biomarkers.

  10. Mass Measurements beyond the Major r-Process Waiting Point {sup 80}Zn

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Baruah, S.; Herlert, A.; Schweikhard, L.

    2008-12-31

    High-precision mass measurements on neutron-rich zinc isotopes {sup 71m,72-81}Zn have been performed with the Penning trap mass spectrometer ISOLTRAP. For the first time, the mass of {sup 81}Zn has been experimentally determined. This makes {sup 80}Zn the first of the few major waiting points along the path of the astrophysical rapid neutron-capture process where neutron-separation energy and neutron-capture Q-value are determined experimentally. The astrophysical conditions required for this waiting point and its associated abundance signatures to occur in r-process models can now be mapped precisely. The measurements also confirm the robustness of the N=50 shell closure for Z=30.

  11. Research on the method of precise alignment technology of atmospheric laser communication

    NASA Astrophysics Data System (ADS)

    Chen, Wen-jian; Gao, Wei; Duan, Yuan-yuan; Ma, Shi-wei; Chen, Jian

    2016-10-01

    Atmosphere laser communication takes advantage of laser as the carrier transmitting the voice, data, and image information in the atmosphere. Because of its high reliability, strong anti-interference ability, the advantages of easy installation, it has great potential and development space in the communications field. In the process of establish communication, the capture, targeting and tracking of the communication signal is the key technology. This paper introduce a method of targeting the signal spot in the process of atmosphere laser communication, which through the way of making analog signal addition and subtraction directly and normalized to obtain the target azimuth information to drive the servo system to achieve precise alignment of tracking.

  12. Optical excitation of carbon nanotubes drives stoichiometric reaction with diazonium salts

    NASA Astrophysics Data System (ADS)

    Powell, Lyndsey; Piao, Yanmei; Wang, Yuhuang; YuHuang Wang Research Group Team

    Covalent chemistry is known to lack the precision required to tailor the physical properties of carbon nanostructures. Here we show that, for the first time, light can be used to drive a typically inefficient reaction with single-walled carbon nanotubes in a more stoichiometric fashion. Specifically, our experimental results suggest that light can enhance the reaction rate of diazonium salt with carbon nanotubes by as much as 35-fold, making possible stoichiometric control of the covalent bonding of a functional group to the sp2 carbon lattice. This light-controlled reaction paves the way for the possibility of highly selective and precise chemistry on single-walled carbon nanotubes and other graphitic nanostructures.

  13. Template optimization and transfer in perceptual learning.

    PubMed

    Kurki, Ilmari; Hyvärinen, Aapo; Saarinen, Jussi

    2016-08-01

    We studied how learning changes the processing of a low-level Gabor stimulus, using a classification-image method (psychophysical reverse correlation) and a task where observers discriminated between slight differences in the phase (relative alignment) of a target Gabor in visual noise. The method estimates the internal "template" that describes how the visual system weights the input information for decisions. One popular idea has been that learning makes the template more like an ideal Bayesian weighting; however, the evidence has been indirect. We used a new regression technique to directly estimate the template weight change and to test whether the direction of reweighting is significantly different from an optimal learning strategy. The subjects trained the task for six daily sessions, and we tested the transfer of training to a target in an orthogonal orientation. Strong learning and partial transfer were observed. We tested whether task precision (difficulty) had an effect on template change and transfer: Observers trained in either a high-precision (small, 60° phase difference) or a low-precision task (180°). Task precision did not have an effect on the amount of template change or transfer, suggesting that task precision per se does not determine whether learning generalizes. Classification images show that training made observers use more task-relevant features and unlearn some irrelevant features. The transfer templates resembled partially optimized versions of templates in training sessions. The template change direction resembles ideal learning significantly but not completely. The amount of template change was highly correlated with the amount of learning.

  14. On the use of programmable hardware and reduced numerical precision in earth-system modeling.

    PubMed

    Düben, Peter D; Russell, Francis P; Niu, Xinyu; Luk, Wayne; Palmer, T N

    2015-09-01

    Programmable hardware, in particular Field Programmable Gate Arrays (FPGAs), promises a significant increase in computational performance for simulations in geophysical fluid dynamics compared with CPUs of similar power consumption. FPGAs allow adjusting the representation of floating-point numbers to specific application needs. We analyze the performance-precision trade-off on FPGA hardware for the two-scale Lorenz '95 model. We scale the size of this toy model to that of a high-performance computing application in order to make meaningful performance tests. We identify the minimal level of precision at which changes in model results are not significant compared with a maximal precision version of the model and find that this level is very similar for cases where the model is integrated for very short or long intervals. It is therefore a useful approach to investigate model errors due to rounding errors for very short simulations (e.g., 50 time steps) to obtain a range for the level of precision that can be used in expensive long-term simulations. We also show that an approach to reduce precision with increasing forecast time, when model errors are already accumulated, is very promising. We show that a speed-up of 1.9 times is possible in comparison to FPGA simulations in single precision if precision is reduced with no strong change in model error. The single-precision FPGA setup shows a speed-up of 2.8 times in comparison to our model implementation on two 6-core CPUs for large model setups.

  15. The quantitative control and matching of an optical false color composite imaging system

    NASA Astrophysics Data System (ADS)

    Zhou, Chengxian; Dai, Zixin; Pan, Xizhe; Li, Yinxi

    1993-10-01

    Design of an imaging system for optical false color composite (OFCC) capable of high-precision density-exposure time control and color balance is presented. The system provides high quality FCC image data that can be analyzed using a quantitative calculation method. The quality requirement to each part of the image generation system is defined, and the distribution of satellite remote sensing image information is analyzed. The proposed technology makes it possible to present the remote sensing image data more effectively and accurately.

  16. Isotopic Abundances as Tracers of the Processes of Lunar Formation

    NASA Astrophysics Data System (ADS)

    Pahlevan, K.

    2011-12-01

    Ever since Apollo, isotopic abundances have been used as tracers to study lunar formation, in particular, to study the sources of the lunar material. In the last decade, however, a number of isotopic similarities have been observed between the lunar samples and the Earth's mantle such that these two reservoirs are now known to be indistinguishable from one another to high precision for a variety of isotopic tracers. This occurs against the backdrop of a Solar System that exhibits widespread heterogeneity with respect to these tracers, a situation that strongly argues that the source of the lunar material is the silicate Earth. To reconcile this observation with the fact that the Moon is thought to result from the collision of two isotopically distinct planetary bodies, a scenario has emerged in which the material from the Moon-forming impactor and the proto-Earth are homogenized in the aftermath of the giant impact. This takes place via turbulent mixing in the time after the giant impact but before lunar accretion while the Earth-Moon system exists in the form of a continuous, high-temperature fluid. Importantly, this high-temperature phase of the evolution occurs in the presence of at least two phases (liquid + vapor) making possible chemical and isotopic fractionation. While equilibrium isotopic fractionation tends to zero at high temperatures, and the post giant impact environment experiences some of the highest temperatures encountered in the Earth sciences, there are several factors that nevertheless make equilibrium isotope effects important probes of this early evolution. (1) Because the vaporization of silicates involves decomposition reactions, the bonding environment for elements in the liquid is often very different from that in the vapor. This difference makes the magnitude of isotopic fractionation intrinsically large, even at the relevant temperatures. (2) Since the isotopic composition of a silicate liquid and co-existing vapor are distinctly different, if the Moon preferentially forms from the liquid or vapor relative to the Earth, mass-dependent isotopic differences at the planetary scale may arise. The large density contrast between liquid and vapor makes phase separation possible. (3) The precision with which planetary isotopic compositions can be determined has increased such that measurements are sensitive to even small degrees of high-temperature phase separation. Using thermodynamic models of silicate liquids to determine the partial vaporization behavior of the major elements, we will present calculations of isotopic fractionation due to liquid-vapor separation for the elements iron, magnesium, silicon, and oxygen. Improvements in analytical precision have largely settled the question of the source of the lunar material - the Earth's mantle - and isotopic measurements are now beginning to yield insight into the high-temperatures processes operating during lunar formation.

  17. High Power Helicon Plasma Source for Plasma Processing

    NASA Astrophysics Data System (ADS)

    Prager, James; Ziemba, Timothy; Miller, Kenneth E.

    2015-09-01

    Eagle Harbor Technologies (EHT), Inc. is developing a high power helicon plasma source. The high power nature and pulsed neutral gas make this source unique compared to traditional helicon source. These properties produce a plasma flow along the magnetic field lines, and therefore allow the source to be decoupled from the reaction chamber. Neutral gas can be injected downstream, which allows for precision control of the ion-neutral ratio at the surface of the sample. Although operated at high power, the source has demonstrated very low impurity production. This source has applications to nanoparticle productions, surface modification, and ionized physical vapor deposition.

  18. Implementation of a high precision multi-measurement time-to-digital convertor on a Kintex-7 FPGA

    NASA Astrophysics Data System (ADS)

    Kuang, Jie; Wang, Yonggang; Cao, Qiang; Liu, Chong

    2018-05-01

    Time-to-digital convertors (TDCs) based on field programmable gate array (FPGA) are becoming more and more popular. Multi-measurement is an effective method to improve TDC precision beyond the cell delay limitation. However, the implementation of TDC with multi-measurement on FPGAs manufactured with 28 nm and more advanced process is facing new challenges. Benefiting from the ones-counter encoding scheme, which was developed in our previous work, we implement a ring oscillator multi-measurement TDC on a Xilinx Kintex-7 FPGA. Using the two TDC channels to measure time-intervals in the range (0 ns-30 ns), the average RMS precision can be improved to 5.76 ps, meanwhile the logic resource usage remains the same with the one-measurement TDC, and the TDC dead time is only 22 ns. The investigation demonstrates that the multi-measurement methods are still available for current main-stream FPGAs. Furthermore, the new implementation in this paper could make the trade-off among the time precision, resource usage and TDC dead time better than ever before.

  19. In vivo blunt-end cloning through CRISPR/Cas9-facilitated non-homologous end-joining

    PubMed Central

    Geisinger, Jonathan M.; Turan, Sören; Hernandez, Sophia; Spector, Laura P.; Calos, Michele P.

    2016-01-01

    The CRISPR/Cas9 system facilitates precise DNA modifications by generating RNA-guided blunt-ended double-strand breaks. We demonstrate that guide RNA pairs generate deletions that are repaired with a high level of precision by non-homologous end-joining in mammalian cells. We present a method called knock-in blunt ligation for exploiting these breaks to insert exogenous PCR-generated sequences in a homology-independent manner without loss of additional nucleotides. This method is useful for making precise additions to the genome such as insertions of marker gene cassettes or functional elements, without the need for homology arms. We successfully utilized this method in human and mouse cells to insert fluorescent protein cassettes into various loci, with efficiencies up to 36% in HEK293 cells without selection. We also created versions of Cas9 fused to the FKBP12-L106P destabilization domain in an effort to improve Cas9 performance. Our in vivo blunt-end cloning method and destabilization-domain-fused Cas9 variant increase the repertoire of precision genome engineering approaches. PMID:26762978

  20. Epidemiology in wonderland: Big Data and precision medicine.

    PubMed

    Saracci, Rodolfo

    2018-03-01

    Big Data and precision medicine, two major contemporary challenges for epidemiology, are critically examined from two different angles. In Part 1 Big Data collected for research purposes (Big research Data) and Big Data used for research although collected for other primary purposes (Big secondary Data) are discussed in the light of the fundamental common requirement of data validity, prevailing over "bigness". Precision medicine is treated developing the key point that high relative risks are as a rule required to make a variable or combination of variables suitable for prediction of disease occurrence, outcome or response to treatment; the commercial proliferation of allegedly predictive tests of unknown or poor validity is commented. Part 2 proposes a "wise epidemiology" approach to: (a) choosing in a context imprinted by Big Data and precision medicine-epidemiological research projects actually relevant to population health, (b) training epidemiologists, (c) investigating the impact on clinical practices and doctor-patient relation of the influx of Big Data and computerized medicine and (d) clarifying whether today "health" may be redefined-as some maintain in purely technological terms.

  1. KSC-2012-6433

    NASA Image and Video Library

    2012-12-05

    CAPE CANAVERAL, Fla. – Technicians prepare to fit a special fixture around an Orion capsule inside the high bay of the Operations & Checkout Building at NASA's Kennedy Space Center in Florida. The fixture is designed to enable precise pre-launch processing of the Orion spacecraft. An Orion capsule is being prepared to make a flight test in 2014 on a mission that will not carry any astronauts. Photo by Tim Jacobs

  2. KSC-2012-6444

    NASA Image and Video Library

    2012-12-05

    CAPE CANAVERAL, Fla. – Technicians prepare to fit a special fixture around an Orion capsule inside the high bay of the Operations & Checkout Building at NASA's Kennedy Space Center in Florida. The fixture is designed to enable precise pre-launch processing of the Orion spacecraft. An Orion capsule is being prepared to make a flight test in 2014 on a mission that will not carry any astronauts. Photo by Tim Jacobs

  3. KSC-2012-6434

    NASA Image and Video Library

    2012-12-05

    CAPE CANAVERAL, Fla. – Technicians prepare to fit a special fixture around an Orion capsule inside the high bay of the Operations & Checkout Building at NASA's Kennedy Space Center in Florida. The fixture is designed to enable precise pre-launch processing of the Orion spacecraft. An Orion capsule is being prepared to make a flight test in 2014 on a mission that will not carry any astronauts. Photo by Tim Jacobs

  4. KSC-2012-6442

    NASA Image and Video Library

    2012-12-05

    CAPE CANAVERAL, Fla. – Technicians prepare to fit a special fixture around an Orion capsule inside the high bay of the Operations & Checkout Building at NASA's Kennedy Space Center in Florida. The fixture is designed to enable precise pre-launch processing of the Orion spacecraft. An Orion capsule is being prepared to make a flight test in 2014 on a mission that will not carry any astronauts. Photo by Tim Jacobs

  5. KSC-2012-6441

    NASA Image and Video Library

    2012-12-05

    CAPE CANAVERAL, Fla. – Technicians prepare to fit a special fixture around an Orion capsule inside the high bay of the Operations & Checkout Building at NASA's Kennedy Space Center in Florida. The fixture is designed to enable precise pre-launch processing of the Orion spacecraft. An Orion capsule is being prepared to make a flight test in 2014 on a mission that will not carry any astronauts. Photo by Tim Jacobs

  6. KSC-2012-6440

    NASA Image and Video Library

    2012-12-05

    CAPE CANAVERAL, Fla. – Technicians prepare to fit a special fixture around an Orion capsule inside the high bay of the Operations & Checkout Building at NASA's Kennedy Space Center in Florida. The fixture is designed to enable precise pre-launch processing of the Orion spacecraft. An Orion capsule is being prepared to make a flight test in 2014 on a mission that will not carry any astronauts. Photo by Tim Jacobs

  7. KSC-2012-6432

    NASA Image and Video Library

    2012-12-05

    CAPE CANAVERAL, Fla. – Technicians prepare to fit a special fixture around an Orion capsule inside the high bay of the Operations & Checkout Building at NASA's Kennedy Space Center in Florida. The fixture is designed to enable precise pre-launch processing of the Orion spacecraft. An Orion capsule is being prepared to make a flight test in 2014 on a mission that will not carry any astronauts. Photo by Tim Jacobs

  8. KSC-2012-6443

    NASA Image and Video Library

    2012-12-05

    CAPE CANAVERAL, Fla. – Technicians prepare to fit a special fixture around an Orion capsule inside the high bay of the Operations & Checkout Building at NASA's Kennedy Space Center in Florida. The fixture is designed to enable precise pre-launch processing of the Orion spacecraft. An Orion capsule is being prepared to make a flight test in 2014 on a mission that will not carry any astronauts. Photo by Tim Jacobs

  9. KSC-2012-6431

    NASA Image and Video Library

    2012-12-05

    CAPE CANAVERAL, Fla. – Technicians prepare to fit a special fixture around an Orion capsule inside the high bay of the Operations & Checkout Building at NASA's Kennedy Space Center in Florida. The fixture is designed to enable precise pre-launch processing of the Orion spacecraft. An Orion capsule is being prepared to make a flight test in 2014 on a mission that will not carry any astronauts. Photo by Tim Jacobs

  10. KSC-2012-6437

    NASA Image and Video Library

    2012-12-05

    CAPE CANAVERAL, Fla. – Technicians prepare to fit a special fixture around an Orion capsule inside the high bay of the Operations & Checkout Building at NASA's Kennedy Space Center in Florida. The fixture is designed to enable precise pre-launch processing of the Orion spacecraft. An Orion capsule is being prepared to make a flight test in 2014 on a mission that will not carry any astronauts. Photo by Tim Jacobs

  11. KSC-2012-6435

    NASA Image and Video Library

    2012-12-05

    CAPE CANAVERAL, Fla. – Technicians prepare to fit a special fixture around an Orion capsule inside the high bay of the Operations & Checkout Building at NASA's Kennedy Space Center in Florida. The fixture is designed to enable precise pre-launch processing of the Orion spacecraft. An Orion capsule is being prepared to make a flight test in 2014 on a mission that will not carry any astronauts. Photo by Tim Jacobs

  12. KSC-2012-6436

    NASA Image and Video Library

    2012-12-05

    CAPE CANAVERAL, Fla. – Technicians prepare to fit a special fixture around an Orion capsule inside the high bay of the Operations & Checkout Building at NASA's Kennedy Space Center in Florida. The fixture is designed to enable precise pre-launch processing of the Orion spacecraft. An Orion capsule is being prepared to make a flight test in 2014 on a mission that will not carry any astronauts. Photo by Tim Jacobs

  13. KSC-2012-6448

    NASA Image and Video Library

    2012-12-06

    CAPE CANAVERAL, Fla. – Technicians lower a special fixture around an Orion spacecraft inside the high bay of the Operations & Checkout Building at NASA's Kennedy Space Center in Florida. The fixture is designed to enable precise pre-launch processing of the Orion spacecraft. An Orion capsule is being prepared to make a flight test in 2014 on a mission that will not carry any astronauts. Photo by Tim Jacobs

  14. KSC-2012-6449

    NASA Image and Video Library

    2012-12-06

    CAPE CANAVERAL, Fla. – Technicians lower a special fixture around an Orion spacecraft inside the high bay of the Operations & Checkout Building at NASA's Kennedy Space Center in Florida. The fixture is designed to enable precise pre-launch processing of the Orion spacecraft. An Orion capsule is being prepared to make a flight test in 2014 on a mission that will not carry any astronauts. Photo by Tim Jacobs

  15. KSC-2012-6450

    NASA Image and Video Library

    2012-12-06

    CAPE CANAVERAL, Fla. – A special fixture stands in place around an Orion spacecraft inside the high bay of the Operations & Checkout Building at NASA's Kennedy Space Center in Florida. The fixture is designed to enable precise pre-launch processing of the Orion spacecraft. An Orion capsule is being prepared to make a flight test in 2014 on a mission that will not carry any astronauts. Photo by Tim Jacobs

  16. KSC-2012-6439

    NASA Image and Video Library

    2012-12-05

    CAPE CANAVERAL, Fla. – Technicians prepare to fit a special fixture around an Orion capsule inside the high bay of the Operations & Checkout Building at NASA's Kennedy Space Center in Florida. The fixture is designed to enable precise pre-launch processing of the Orion spacecraft. An Orion capsule is being prepared to make a flight test in 2014 on a mission that will not carry any astronauts. Photo by Tim Jacobs

  17. KSC-2012-6438

    NASA Image and Video Library

    2012-12-05

    CAPE CANAVERAL, Fla. – Technicians prepare to fit a special fixture around an Orion capsule inside the high bay of the Operations & Checkout Building at NASA's Kennedy Space Center in Florida. The fixture is designed to enable precise pre-launch processing of the Orion spacecraft. An Orion capsule is being prepared to make a flight test in 2014 on a mission that will not carry any astronauts. Photo by Tim Jacobs

  18. Precise, High-throughput Analysis of Bacterial Growth.

    PubMed

    Kurokawa, Masaomi; Ying, Bei-Wen

    2017-09-19

    Bacterial growth is a central concept in the development of modern microbial physiology, as well as in the investigation of cellular dynamics at the systems level. Recent studies have reported correlations between bacterial growth and genome-wide events, such as genome reduction and transcriptome reorganization. Correctly analyzing bacterial growth is crucial for understanding the growth-dependent coordination of gene functions and cellular components. Accordingly, the precise quantitative evaluation of bacterial growth in a high-throughput manner is required. Emerging technological developments offer new experimental tools that allow updates of the methods used for studying bacterial growth. The protocol introduced here employs a microplate reader with a highly optimized experimental procedure for the reproducible and precise evaluation of bacterial growth. This protocol was used to evaluate the growth of several previously described Escherichia coli strains. The main steps of the protocol are as follows: the preparation of a large number of cell stocks in small vials for repeated tests with reproducible results, the use of 96-well plates for high-throughput growth evaluation, and the manual calculation of two major parameters (i.e., maximal growth rate and population density) representing the growth dynamics. In comparison to the traditional colony-forming unit (CFU) assay, which counts the cells that are cultured in glass tubes over time on agar plates, the present method is more efficient and provides more detailed temporal records of growth changes, but has a stricter detection limit at low population densities. In summary, the described method is advantageous for the precise and reproducible high-throughput analysis of bacterial growth, which can be used to draw conceptual conclusions or to make theoretical observations.

  19. Neutron activation analyses and half-life measurements at the usgs triga reactor

    NASA Astrophysics Data System (ADS)

    Larson, Robert E.

    Neutron activation of materials followed by gamma spectroscopy using high-purity germanium detectors is an effective method for making measurements of nuclear beta decay half-lives and for detecting trace amounts of elements present in materials. This research explores applications of neutron activation analysis (NAA) in two parts. Part 1. High Precision Methods for Measuring Decay Half-Lives, Chapters 1 through 8 Part one develops research methods and data analysis techniques for making high precision measurements of nuclear beta decay half-lives. The change in the electron capture half-life of 51Cr in pure chromium versus chromium mixed in a gold lattice structure is explored, and the 97Ru electron capture decay half-life are compared for ruthenium in a pure crystal versus ruthenium in a rutile oxide state, RuO2. In addition, the beta-minus decay half-life of 71mZn is measured and compared with new high precision findings. Density Functional Theory is used to explain the measured magnitude of changes in electron capture half-life from changes in the surrounding lattice electron configuration. Part 2. Debris Collection Nuclear Diagnostic at the National Ignition Facility, Chapters 9 through 11 Part two explores the design and development of a solid debris collector for use as a diagnostic tool at the National Ignition Facility (NIF). NAA measurements are performed on NIF post-shot debris collected on witness plates in the NIF chamber. In this application NAA is used to detect and quantify the amount of trace amounts of gold from the hohlraum and germanium from the pellet present in the debris collected after a NIF shot. The design of a solid debris collector based on material x-ray ablation properties is given, and calculations are done to predict performance and results for the collection and measurements of trace amounts of gold and germanium from dissociated hohlraum debris.

  20. Engineering of Machine tool’s High-precision electric drives

    NASA Astrophysics Data System (ADS)

    Khayatov, E. S.; Korzhavin, M. E.; Naumovich, N. I.

    2018-03-01

    In the article it is shown that in mechanisms with numerical program control, high quality of processes can be achieved only in systems that provide adjustment of the working element’s position with high accuracy, and this requires an expansion of the regulation range by the torque. In particular, the use of synchronous reactive machines with independent excitation control makes it possible to substantially increase the moment overload in the sequential excitation circuit. Using mathematical and physical modeling methods, it is shown that in the electric drive with a synchronous reactive machine with independent excitation in a circuit with sequential excitation, it is possible to significantly expand the range of regulation by the torque and this is achieved by the effect of sequential excitation, which makes it possible to compensate for the transverse reaction of the armature.

  1. Sampling animal sign in heterogeneous environments: how much is enough?

    USGS Publications Warehouse

    Holbrook, Joseph D.; Arkle, Robert S.; Rachlow, Janet L.; Vierling, Kerri T.; Pilliod, David S.

    2015-01-01

    Animal ecologists often use animal sign as a surrogate for direct observation of organisms, especially when species are secretive or difficult to observe. Spatial heterogeneity in arid environments makes it challenging to consistently detect and precisely characterize animal sign, which can bias estimates of animal abundance or habitat use. Piute ground squirrels (Urocitellus mollis) and Owyhee harvester ants (Pogonomyrmex salinus) live in arid environments and are fossorial, which can make them difficult to observe directly. Their relative abundance can be assessed using sign (i.e., burrows and nests). We implemented an over-sampling framework (i.e., recorded an excessive amount of information) with two observers to 1) identify a sampling intensity that balanced precision with our resource constraints, and 2) assess classification and detection of squirrel burrows and ant nests across vegetation conditions. We sampled 20 1-ha plots for ground squirrel burrows and ant nests using six 4 m × 100 m belt transects. Analyses of precision and sampling effort indicated that three belt transects covering 1200 m2 per ha provided sufficient precision, while minimizing effort. Regardless of vegetation conditions, counts by two observers were strongly correlated for ground squirrel burrows (r = 0.99, P < 0.001, df = 18; slope = 0.92) and harvester ant nests (r = 0.99, P < 0.001, df = 18; slope = 1.01) indicating observer consistency and perhaps high detection probability. These findings illustrate an approach for evaluating sampling designs in many ecological contexts.

  2. Application of CCD drift-scan photoelectric technique on monitoring GEO satellites

    NASA Astrophysics Data System (ADS)

    Yu, Yong; Zhao, Xiao-Fen; Luo, Hao; Mao, Yin-Dun; Tang, Zheng-Hong

    2018-05-01

    Geosynchronous Earth Orbit (GEO) satellites are widely used because of their unique characteristics of high-orbit and remaining permanently in the same area of the sky. Precise monitoring of GEO satellites can provide a key reference for the judgment of satellite operation status, the capture and identification of targets, and the analysis of collision warning. The observation using ground-based optical telescopes plays an important role in the field of monitoring GEO targets. Different from distant celestial bodies, there is a relative movement between the GEO target and the background reference stars, which makes the conventional observation method limited for long focal length telescopes. CCD drift-scan photoelectric technique is applied on monitoring GEO targets. In the case of parking the telescope, the good round images of the background reference stars and the GEO target at the same sky region can be obtained through the alternating observation of CCD drift-scan mode and CCD stare mode, so as to improve the precision of celestial positioning for the GEO target. Observation experiments of GEO targets were carried out with 1.56-meter telescope of Shanghai Astronomical Observatory. The results show that the application of CCD drift-scan photoelectric technique makes the precision of observing the GEO target reach the level of 0.2″, which gives full play to the advantage of the long focal length of the telescope. The effect of orbit improvement based on multi-pass of observations is obvious and the prediction precision of extrapolating to 72-h is in the order of several arc seconds in azimuth and elevation.

  3. Evaluation Applied to Reliability Analysis of Reconfigurable, Highly Reliable, Fault-Tolerant, Computing Systems for Avionics

    NASA Technical Reports Server (NTRS)

    Migneault, G. E.

    1979-01-01

    Emulation techniques are proposed as a solution to a difficulty arising in the analysis of the reliability of highly reliable computer systems for future commercial aircraft. The difficulty, viz., the lack of credible precision in reliability estimates obtained by analytical modeling techniques are established. The difficulty is shown to be an unavoidable consequence of: (1) a high reliability requirement so demanding as to make system evaluation by use testing infeasible, (2) a complex system design technique, fault tolerance, (3) system reliability dominated by errors due to flaws in the system definition, and (4) elaborate analytical modeling techniques whose precision outputs are quite sensitive to errors of approximation in their input data. The technique of emulation is described, indicating how its input is a simple description of the logical structure of a system and its output is the consequent behavior. The use of emulation techniques is discussed for pseudo-testing systems to evaluate bounds on the parameter values needed for the analytical techniques.

  4. Extraction of impacted mandibular third molars - the effect of osteotomy at two speeds on peripheral bone: a histopathological analysis.

    PubMed

    Siroraj, A Pearlcid; Giri G V V; Ramkumar, Subramaniam; Narasimhan, Malathi

    2016-05-01

    The aim of this study was to find out the ideal speed for making a precise osteotomy with minimal damage to the surrounding bone. Thirty-six patients were divided into two groups (n=18 in each) depending on the speed of the handpiece used for osteotomy (slow=20000rpm and fast=40000rpm). Samples were taken from the peripheral bone and examined histologically to measure the margins of the osteotomy, the amount of debris produced, and the degree of thermal osteonecrosis. The osteotomy made with the high speed handpiece was better than that made with the low speed one on all counts. The margins in the high speed group were more or less precisely as required, with less debris and no thermal necrosis, which illustrated the efficacy of a high speed osteotomy. These findings can apply to other procedures that involve osteotomies in maxillofacial surgery. Copyright © 2016 The British Association of Oral and Maxillofacial Surgeons. Published by Elsevier Ltd. All rights reserved.

  5. A two-ply polymer-based flexible tactile sensor sheet using electric capacitance.

    PubMed

    Guo, Shijie; Shiraoka, Takahisa; Inada, Seisho; Mukai, Toshiharu

    2014-01-29

    Traditional capacitive tactile sensor sheets usually have a three-layered structure, with a dielectric layer sandwiched by two electrode layers. Each electrode layer has a number of parallel ribbon-like electrodes. The electrodes on the two electrode layers are oriented orthogonally and each crossing point of the two perpendicular electrode arrays makes up a capacitive sensor cell on the sheet. It is well known that compatibility between measuring precision and resolution is difficult, since decreasing the width of the electrodes is required to obtain a high resolution, however, this may lead to reduction of the area of the sensor cells, and as a result, lead to a low Signal/Noise (S/N) ratio. To overcome this problem, a new multilayered structure and related calculation procedure are proposed. This new structure stacks two or more sensor sheets with shifts in position. Both a high precision and a high resolution can be obtained by combining the signals of the stacked sensor sheets. Trial production was made and the effect was confirmed.

  6. Automation of ⁹⁹Tc extraction by LOV prior ICP-MS detection: application to environmental samples.

    PubMed

    Rodríguez, Rogelio; Leal, Luz; Miranda, Silvia; Ferrer, Laura; Avivar, Jessica; García, Ariel; Cerdà, Víctor

    2015-02-01

    A new, fast, automated and inexpensive sample pre-treatment method for (99)Tc determination by inductively coupled plasma-mass spectrometry (ICP-MS) detection is presented. The miniaturized approach is based on a lab-on-valve (LOV) system, allowing automatic separation and preconcentration of (99)Tc. Selectivity is provided by the solid phase extraction system used (TEVA resin) which retains selectively pertechnetate ion in diluted nitric acid solution. The proposed system has some advantages such as minimization of sample handling, reduction of reagents volume, improvement of intermediate precision and sample throughput, offering a significant decrease of both time and cost per analysis in comparison to other flow techniques and batch methods. The proposed LOV system has been successfully applied to different samples of environmental interest (water and soil) with satisfactory recoveries, between 94% and 98%. The detection limit (LOD) of the developed method is 0.005 ng. The high durability of the resin and its low amount (32 mg), its good intermediate precision (RSD 3.8%) and repeatability (RSD 2%) and its high extraction frequency (up to 5 h(-1)) makes this method an inexpensive, high precision and fast tool for monitoring (99)Tc in environmental samples. Copyright © 2014 Elsevier B.V. All rights reserved.

  7. Aspects of ultra-high-precision diamond machining of RSA 443 optical aluminium

    NASA Astrophysics Data System (ADS)

    Mkoko, Z.; Abou-El-Hossein, K.

    2015-08-01

    Optical aluminium alloys such as 6061-T6 are traditionally used in ultra-high precision manufacturing for making optical mirrors for aerospace and other applications. However, the optics industry has recently witnessed the development of more advanced optical aluminium grades that are capable of addressing some of the issues encountered when turning with single-point natural monocrystalline diamond cutters. The advent of rapidly solidified aluminium (RSA) grades has generally opened up new possibilities for ultra-high precision manufacturing of optical components. In this study, experiments were conducted with single-point diamond cutters on rapidly solidified aluminium RSA 443 material. The objective of this study is to observe the effects of depth of cut and feed rate at a fixed rotational speed on the tool wear rate and resulting surface roughness of diamond turned specimens. This is done to gain further understanding of the rate of wear on the diamond cutters versus the surface texture generated on the RSA 443 material. The diamond machining experiments yielded machined surfaces which are less reflective but with consistent surface roughness values. Cutting tools were observed for wear through scanning microscopy; relatively low wear pattern was evident on the diamond tool edge. The highest tool wear were obtained at higher depth of cut and increased feed rate.

  8. Jig For Stereoscopic Photography

    NASA Technical Reports Server (NTRS)

    Nielsen, David J.

    1990-01-01

    Separations between views adjusted precisely for best results. Simple jig adjusted to set precisely, distance between right and left positions of camera used to make stereoscopic photographs. Camera slides in slot between extreme positions, where it takes stereoscopic pictures. Distance between extreme positions set reproducibly with micrometer. In view of trend toward very-large-scale integration of electronic circuits, training method and jig used to make training photographs useful to many companies to reduce cost of training manufacturing personnel.

  9. A Very High Order, Adaptable MESA Implementation for Aeroacoustic Computations

    NASA Technical Reports Server (NTRS)

    Dydson, Roger W.; Goodrich, John W.

    2000-01-01

    Since computational efficiency and wave resolution scale with accuracy, the ideal would be infinitely high accuracy for problems with widely varying wavelength scales. Currently, many of the computational aeroacoustics methods are limited to 4th order accurate Runge-Kutta methods in time which limits their resolution and efficiency. However, a new procedure for implementing the Modified Expansion Solution Approximation (MESA) schemes, based upon Hermitian divided differences, is presented which extends the effective accuracy of the MESA schemes to 57th order in space and time when using 128 bit floating point precision. This new approach has the advantages of reducing round-off error, being easy to program. and is more computationally efficient when compared to previous approaches. Its accuracy is limited only by the floating point hardware. The advantages of this new approach are demonstrated by solving the linearized Euler equations in an open bi-periodic domain. A 500th order MESA scheme can now be created in seconds, making these schemes ideally suited for the next generation of high performance 256-bit (double quadruple) or higher precision computers. This ease of creation makes it possible to adapt the algorithm to the mesh in time instead of its converse: this is ideal for resolving varying wavelength scales which occur in noise generation simulations. And finally, the sources of round-off error which effect the very high order methods are examined and remedies provided that effectively increase the accuracy of the MESA schemes while using current computer technology.

  10. Clinical Ion Beam Applications: Basic Properties, Application, Quality Control, Planning

    NASA Astrophysics Data System (ADS)

    Kraft, Gerhard

    2009-03-01

    Heavy-ion therapy using beam scanning and biological dose optimization is a novel technique of high-precision external radiotherapy. It yields a better perspective for tumor cure of radio-resistant tumors. However, heavy-ion therapy is not a general solution for all types of tumors. As compared to conventional radiotherapy, heavy-ion radiotherapy has the advantages of higher tumor dose, improved sparing of normal tissue in the entrance channel, a more precise concentration of the dose in the target volume with steeper gradients to the normal tissue, and a higher radiobiological effectiveness for tumors which are radio-resistant in conventional therapy. These properties make it possible to treat radio-resistant tumors with great success, including those in close vicinity to critical organs.

  11. Development and Characterization of 6Li-doped Liquid Scintillator Detectors for PROSPECT

    NASA Astrophysics Data System (ADS)

    Gaison, Jeremy; Prospect Collaboration

    2016-09-01

    PROSPECT, the Precision Reactor Oscillation and Spectrum experiment, is a phased reactor antineutrino experiment designed to search for eV-scale sterile neutrinos via short-baseline neutrino oscillations and to make a precision measurement of the 235U reactor antineutrino spectrum. A multi-ton, optically segmented detector will be deployed at Oak Ridge National Laboratory's (ORNL) High Flux Isotope Reactor (HFIR) to measure the reactor spectrum at baselines ranging from 7-12m. A two-segment detector prototype with 50 liters of active liquid scintillator target has been built to verify the detector design and to benchmark its performance. In this presentation, we will summarize the performance of this detector prototype and describe the optical and energy calibration of the segmented PROSPECT detectors.

  12. A time projection chamber for high accuracy and precision fission cross-section measurements

    DOE PAGES

    Heffner, M.; Asner, D. M.; Baker, R. G.; ...

    2014-05-22

    The fission Time Projection Chamber (fissionTPC) is a compact (15 cm diameter) two-chamber MICROMEGAS TPC designed to make precision cross-section measurements of neutron-induced fission. The actinide targets are placed on the central cathode and irradiated with a neutron beam that passes axially through the TPC inducing fission in the target. The 4π acceptance for fission fragments and complete charged particle track reconstruction are powerful features of the fissionTPC which will be used to measure fission cross-sections and examine the associated systematic errors. This study provides a detailed description of the design requirements, the design solutions, and the initial performance ofmore » the fissionTPC.« less

  13. [Progress in precision medicine: a scientific perspective].

    PubMed

    Wang, B; Li, L M

    2017-01-10

    Precision medicine is a new strategy for disease prevention and treatment by taking into account differences in genetics, environment and lifestyles among individuals and making precise diseases classification and diagnosis, which can provide patients with personalized, targeted prevention and treatment. Large-scale population cohort studies are fundamental for precision medicine research, and could produce best evidence for precision medicine practices. Current criticisms on precision medicine mainly focus on the very small proportion of benefited patients, the neglect of social determinants for health, and the possible waste of limited medical resources. In spite of this, precision medicine is still a most hopeful research area, and would become a health care practice model in the future.

  14. Gas Nonideality at One Atmosphere Revealed through Speed of Sound Measurements and Heat Capacity Determinations

    ERIC Educational Resources Information Center

    Halpern, Arthur M.; Liu, Allen

    2008-01-01

    Using an easy-to-make cylindrical resonator, students can measure the speed of sound in a gas, u, with sufficiently high precision (by locating standing-wave Lissajous patterns on an oscilloscope) to observe real gas properties at one atmosphere and 300 K. For CO[subscript 2] and SF[subscript 6], u is found to be 268.83 and 135.25 m s[superscript…

  15. An Extended ADOP for Performance Evaluation of Single-Frequency Single-Epoch Positioning by BDS/GPS in Asia-Pacific Region

    PubMed Central

    Liu, Xin; Zhang, Shubi; Zhang, Qiuzhao; Yang, Wei

    2017-01-01

    Single-Frequency Single-Epoch (SFSE) high-precision positioning has always been the hot spot of Global Navigation Satellite System (GNSS), and ambiguity dilution of precision (ADOP) is a well-known scalar measure for success rate of ambiguity resolution. Traditional ADOP expression is complicated, thus the SFSE extended ADOP (E-ADOP), with the newly defined Summation-Multiplication Ratio of Weight (SMRW) and two theorems for short baseline, was developed. This simplifies the ADOP expression; gives a clearer insight into the influences of SMRW and number of satellites on E-ADOP; and makes theoretical analysis of E-ADOP more convenient than that of ADOP, and through that the E-ADOP value can be predicted more accurately than through the ADOP expression for ADOP value. E-ADOP reveals that number of satellites and SMRW or high-elevation satellite are important for ADOP and, through E-ADOP, we studied which factor is dominant to control ADOP in different conditions and make ADOP different between BeiDou Navigation Satellite System (BDS), Global Positioning System (GPS), and BDS/GPS. Based on experimental results of SFSE positioning with different baselines, some conclusions are made: (1) ADOP decreases when new satellites are added mainly because the number of satellites becomes larger; (2) when the number of satellites is constant, ADOP is mainly affected by SMRW; (3) in contrast to systems where the satellites with low-elevation are the majority or where low- and high-elevation satellites are equally distributed, in systems where the high-elevation satellites are the majority, the SMRW mainly makes ADOP smaller, even if there are fewer satellites than in the two previous cases, and the difference in numbers of satellites can be expanded as the proportion of high-elevation satellites becomes larger; and (4) ADOP of BDS is smaller than ADOP of GPS mainly because of its SMRW. PMID:28973977

  16. Optical technologies for space sensor

    NASA Astrophysics Data System (ADS)

    Wang, Hu; Liu, Jie; Xue, Yaoke; Liu, Yang; Liu, Meiying; Wang, Lingguang; Yang, Shaodong; Lin, Shangmin; Chen, Su; Luo, Jianjun

    2015-10-01

    Space sensors are used in navigation sensor fields. The sun, the earth, the moon and other planets are used as frame of reference to obtain stellar position coordinates, and then to control the attitude of an aircraft. Being the "eyes" of the space sensors, Optical sensor system makes images of the infinite far stars and other celestial bodies. It directly affects measurement accuracy of the space sensor, indirectly affecting the data updating rate. Star sensor technology is the pilot for Space sensors. At present more and more attention is paid on all-day star sensor technology. By day and night measurements of the stars, the aircraft's attitude in the inertial coordinate system can be provided. Facing the requirements of ultra-high-precision, large field of view, wide spectral range, long life and high reliability, multi-functional optical system, we integration, integration optical sensors will be future space technology trends. In the meantime, optical technologies for space-sensitive research leads to the development of ultra-precision optical processing, optical and precision test machine alignment technology. It also promotes the development of long-life optical materials and applications. We have achieved such absolute distortion better than ±1um, Space life of at least 15years of space-sensitive optical system.

  17. The precise temporal calibration of dinosaur origins.

    PubMed

    Marsicano, Claudia A; Irmis, Randall B; Mancuso, Adriana C; Mundil, Roland; Chemale, Farid

    2016-01-19

    Dinosaurs have been major components of ecosystems for over 200 million years. Although different macroevolutionary scenarios exist to explain the Triassic origin and subsequent rise to dominance of dinosaurs and their closest relatives (dinosauromorphs), all lack critical support from a precise biostratigraphically independent temporal framework. The absence of robust geochronologic age control for comparing alternative scenarios makes it impossible to determine if observed faunal differences vary across time, space, or a combination of both. To better constrain the origin of dinosaurs, we produced radioisotopic ages for the Argentinian Chañares Formation, which preserves a quintessential assemblage of dinosaurian precursors (early dinosauromorphs) just before the first dinosaurs. Our new high-precision chemical abrasion thermal ionization mass spectrometry (CA-TIMS) U-Pb zircon ages reveal that the assemblage is early Carnian (early Late Triassic), 5- to 10-Ma younger than previously thought. Combined with other geochronologic data from the same basin, we constrain the rate of dinosaur origins, demonstrating their relatively rapid origin in a less than 5-Ma interval, thus halving the temporal gap between assemblages containing only dinosaur precursors and those with early dinosaurs. After their origin, dinosaurs only gradually dominated mid- to high-latitude terrestrial ecosystems millions of years later, closer to the Triassic-Jurassic boundary.

  18. Optogenetic Functional MRI

    PubMed Central

    Lin, Peter; Fang, Zhongnan; Liu, Jia; Lee, Jin Hyung

    2016-01-01

    The investigation of the functional connectivity of precise neural circuits across the entire intact brain can be achieved through optogenetic functional magnetic resonance imaging (ofMRI), which is a novel technique that combines the relatively high spatial resolution of high-field fMRI with the precision of optogenetic stimulation. Fiber optics that enable delivery of specific wavelengths of light deep into the brain in vivo are implanted into regions of interest in order to specifically stimulate targeted cell types that have been genetically induced to express light-sensitive trans-membrane conductance channels, called opsins. fMRI is used to provide a non-invasive method of determining the brain's global dynamic response to optogenetic stimulation of specific neural circuits through measurement of the blood-oxygen-level-dependent (BOLD) signal, which provides an indirect measurement of neuronal activity. This protocol describes the construction of fiber optic implants, the implantation surgeries, the imaging with photostimulation and the data analysis required to successfully perform ofMRI. In summary, the precise stimulation and whole-brain monitoring ability of ofMRI are crucial factors in making ofMRI a powerful tool for the study of the connectomics of the brain in both healthy and diseased states. PMID:27167840

  19. Biotemplated Morpho Butterfly Wings for Tunable Structurally Colored Photocatalysts.

    PubMed

    Rodríguez, Robin E; Agarwal, Sneha P; An, Shun; Kazyak, Eric; Das, Debashree; Shang, Wen; Skye, Rachael; Deng, Tao; Dasgupta, Neil P

    2018-02-07

    Morpho sulkowskyi butterfly wings contain naturally occurring hierarchical nanostructures that produce structural coloration. The high aspect ratio and surface area of these wings make them attractive nanostructured templates for applications in solar energy and photocatalysis. However, biomimetic approaches to replicate their complex structural features and integrate functional materials into their three-dimensional framework are highly limited in precision and scalability. Herein, a biotemplating approach is presented that precisely replicates Morpho nanostructures by depositing nanocrystalline ZnO coatings onto wings via low-temperature atomic layer deposition (ALD). This study demonstrates the ability to precisely tune the natural structural coloration while also integrating multifunctionality by imparting photocatalytic activity onto fully intact Morpho wings. Optical spectroscopy and finite-difference time-domain numerical modeling demonstrate that ALD ZnO coatings can rationally tune the structural coloration across the visible spectrum. These structurally colored photocatalysts exhibit an optimal coating thickness to maximize photocatalytic activity, which is attributed to trade-offs between light absorption and catalytic quantum yield with increasing coating thickness. These multifunctional photocatalysts present a new approach to integrating solar energy harvesting into visually attractive surfaces that can be integrated into building facades or other macroscopic structures to impart aesthetic appeal.

  20. Target templates: the precision of mental representations affects attentional guidance and decision-making in visual search.

    PubMed

    Hout, Michael C; Goldinger, Stephen D

    2015-01-01

    When people look for things in the environment, they use target templates-mental representations of the objects they are attempting to locate-to guide attention and to assess incoming visual input as potential targets. However, unlike laboratory participants, searchers in the real world rarely have perfect knowledge regarding the potential appearance of targets. In seven experiments, we examined how the precision of target templates affects the ability to conduct visual search. Specifically, we degraded template precision in two ways: 1) by contaminating searchers' templates with inaccurate features, and 2) by introducing extraneous features to the template that were unhelpful. We recorded eye movements to allow inferences regarding the relative extents to which attentional guidance and decision-making are hindered by template imprecision. Our findings support a dual-function theory of the target template and highlight the importance of examining template precision in visual search.

  1. Target templates: the precision of mental representations affects attentional guidance and decision-making in visual search

    PubMed Central

    Hout, Michael C.; Goldinger, Stephen D.

    2014-01-01

    When people look for things in the environment, they use target templates—mental representations of the objects they are attempting to locate—to guide attention and to assess incoming visual input as potential targets. However, unlike laboratory participants, searchers in the real world rarely have perfect knowledge regarding the potential appearance of targets. In seven experiments, we examined how the precision of target templates affects the ability to conduct visual search. Specifically, we degraded template precision in two ways: 1) by contaminating searchers’ templates with inaccurate features, and 2) by introducing extraneous features to the template that were unhelpful. We recorded eye movements to allow inferences regarding the relative extents to which attentional guidance and decision-making are hindered by template imprecision. Our findings support a dual-function theory of the target template and highlight the importance of examining template precision in visual search. PMID:25214306

  2. Optical spectroscopy of atomic and molecular positronium

    NASA Astrophysics Data System (ADS)

    Mills, A. P., Jr.

    2014-04-01

    Positronium (Ps) is a purely leptonic hydrogen-like atom formed from an electron and a positron. Since the interactions of electrons and positrons are thought to be almost entirely electromagnetic, precision measurements of the Ps energy levels should constitute a good test of QED theory. The ultimate precision is limited by the rapid annihilation of the various Ps states and the number of Ps atoms available. Much progress in making better Ps sources has been made since the 1950's when Ps was discovered and its principle characteristics measured in by the pioneering experiments of Martin Deutsch. The most notable milestones were the first reproducible schemes for making slow positrons and Ps in vacuum by Canter and his co-workers in the 1970's and the discovery of the enabling technology for accumulating slow positrons by Surko and co-workers in 1989. These techniques have made it possible to generate high density bursts of slow Ps atoms that has led to the production of di-positronium molecules, Ps2, and the observation of the Lyman-alpha-like transition in Ps2 at a wavelength of 251 nm predicted by Varga and co-workers. The possibilities for 1S-2S spectroscopy of triplet and singlet Ps with precisions relevant to the proton charge radius problem and efficient production of slow Rydberg Ps atoms useful for measuring Ps free fall are discussed.

  3. Introducing the Precision Isotope Ratio Mass Spectrometer: Novel Innovations in Multi-Collector Arrays for Isotopologues and Isotopomers in Organic Molecule Gas Analysis

    NASA Astrophysics Data System (ADS)

    Kasson, A.

    2016-12-01

    In January 2016, elementar Analysensysteme, GmbH (Germany), in conjunction with their daughter company, Isoprime Ltd. (United Kingdom) released the Precision isotope ratio mass spectrometer. The Precision is the newest light element IRMS on the market and adds some unique hardware and software functionalities to the basic core of stable isotopic research previously unseen. Although this system is designed to make the typical bulk and compound specific measurements that functioning stable isotope laboratories have been accustomed to, it has been designed to make complicated measurements of isotopologues, isotopomers and clumped isotopes much more turnkey and user friendly. Here we focus on some datasets that have been collected from three different beta test sites and highlight the functional use of the new hardware in conjunction with ionOS operating software. As part of those highlights, the improved precision, accuracy and ion optics of the Precision IRMS will be demonstrated. In addition, we intend to show that the reprocessing functions on the ionOS software package are not only beneficial to users of just the Precision IRMS, but to the entire stable isotope community as a whole.

  4. The artificial retina processor for track reconstruction at the LHC crossing rate

    DOE PAGES

    Abba, A.; Bedeschi, F.; Citterio, M.; ...

    2015-03-16

    We present results of an R&D study for a specialized processor capable of precisely reconstructing, in pixel detectors, hundreds of charged-particle tracks from high-energy collisions at 40 MHz rate. We apply a highly parallel pattern-recognition algorithm, inspired by studies of the processing of visual images by the brain as it happens in nature, and describe in detail an efficient hardware implementation in high-speed, high-bandwidth FPGA devices. This is the first detailed demonstration of reconstruction of offline-quality tracks at 40 MHz and makes the device suitable for processing Large Hadron Collider events at the full crossing frequency.

  5. Microbarograph - ESRL Hi-Res Microbarograph, Goldendale - Raw Data

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    McCaffrey, Katherine

    High-precision barometers (Paroscientific 6000-16B-IS) are combined with Nishiyama-Bedard Quad Disk pressure probes, measuring pressure (mb) at the surface, nominally 2 m above ground level. Data are sampled at 20 Hz for potential studies of turbulence. The sensors' high accuracy makes them useful for determining horizontal pressure gradients and their relation to wind ramp events, as well as the temporal variability of pressure associated with mountain wakes and waves. **Note different ASCII file formats for Goldendale (z04) and Walla Walla (z09) sites.**

  6. Microbarograph - ESRL Hi-Res Microbarograph, Condon - Reviewed Data

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    McCaffrey, Katherine

    High-precision barometers (Paroscientific 6000-16B-IS) are combined with Nishiyama-Bedard Quad Disk pressure probes, measuring pressure (mb) at the surface, nominally 2 m above ground level. Data are sampled at 20 Hz for potential studies of turbulence. The sensors' high accuracy makes them useful for determining horizontal pressure gradients and their relation to wind ramp events, as well as the temporal variability of pressure associated with mountain wakes and waves. **Note different ASCII file formats for Goldendale (z04) and Walla Walla (z09) sites.**

  7. Microbarograph - ESRL Hi-Res Microbarograph, Troutdale - Raw Data

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    McCaffrey, Katherine

    High-precision barometers (Paroscientific 6000-16B-IS) are combined with Nishiyama-Bedard Quad Disk pressure probes, measuring pressure (mb) at the surface, nominally 2 m above ground level. Data are sampled at 20 Hz for potential studies of turbulence. The sensors' high accuracy makes them useful for determining horizontal pressure gradients and their relation to wind ramp events, as well as the temporal variability of pressure associated with mountain wakes and waves. **Note different ASCII file formats for Goldendale (z04) and Walla Walla (z09) sites.**

  8. Microbarograph - ESRL Hi-Res Microbarograph, Troutdale - Reviewed Data

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    McCaffrey, Katherine

    High-precision barometers (Paroscientific 6000-16B-IS) are combined with Nishiyama-Bedard Quad Disk pressure probes, measuring pressure (mb) at the surface, nominally 2 m above ground level. Data are sampled at 20 Hz for potential studies of turbulence. The sensors' high accuracy makes them useful for determining horizontal pressure gradients and their relation to wind ramp events, as well as the temporal variability of pressure associated with mountain wakes and waves. **Note different ASCII file formats for Goldendale (z04) and Walla Walla (z09) sites.**

  9. Microbarograph - ESRL Hi-Res Microbarograph, Condon - Raw Data

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    McCaffrey, Katherine

    High-precision barometers (Paroscientific 6000-16B-IS) are combined with Nishiyama-Bedard Quad Disk pressure probes, measuring pressure (mb) at the surface, nominally 2 m above ground level. Data are sampled at 20 Hz for potential studies of turbulence. The sensors' high accuracy makes them useful for determining horizontal pressure gradients and their relation to wind ramp events, as well as the temporal variability of pressure associated with mountain wakes and waves. **Note different ASCII file formats for Goldendale (z04) and Walla Walla (z09) sites.**

  10. Microbarograph - ESRL Hi-Res Microbarograph, Wasco Airport - Reviewed Data

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    McCaffrey, Katherine

    High-precision barometers (Paroscientific 6000-16B-IS) are combined with Nishiyama-Bedard Quad Disk pressure probes, measuring pressure (mb) at the surface, nominally 2 m above ground level. Data are sampled at 20 Hz for potential studies of turbulence. The sensors' high accuracy makes them useful for determining horizontal pressure gradients and their relation to wind ramp events, as well as the temporal variability of pressure associated with mountain wakes and waves. **Note different ASCII file formats for Goldendale (z04) and Walla Walla (z09) sites.**

  11. Microbarograph - ESRL Hi-Res Microbarograph, Walla Walla - Raw Data

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    McCaffrey, Katherine

    High-precision barometers (Paroscientific 6000-16B-IS) are combined with Nishiyama-Bedard Quad Disk pressure probes, measuring pressure (mb) at the surface, nominally 2 m above ground level. Data are sampled at 20 Hz for potential studies of turbulence. The sensors' high accuracy makes them useful for determining horizontal pressure gradients and their relation to wind ramp events, as well as the temporal variability of pressure associated with mountain wakes and waves. **Note different ASCII file formats for Goldendale (z04) and Walla Walla (z09) sites.**

  12. Microbarograph - ESRL Hi-Res Microbarograph, Goldendale - Reviewed Data

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    McCaffrey, Katherine

    High-precision barometers (Paroscientific 6000-16B-IS) are combined with Nishiyama-Bedard Quad Disk pressure probes, measuring pressure (mb) at the surface, nominally 2 m above ground level. Data are sampled at 20 Hz for potential studies of turbulence. The sensors' high accuracy makes them useful for determining horizontal pressure gradients and their relation to wind ramp events, as well as the temporal variability of pressure associated with mountain wakes and waves. **Note different ASCII file formats for Goldendale (z04) and Walla Walla (z09) sites.**

  13. Microbarograph - ESRL Hi-Res Microbarograph, Walla Walla - Reviewed Data

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    McCaffrey, Katherine

    High-precision barometers (Paroscientific 6000-16B-IS) are combined with Nishiyama-Bedard Quad Disk pressure probes, measuring pressure (mb) at the surface, nominally 2 m above ground level. Data are sampled at 20 Hz for potential studies of turbulence. The sensors' high accuracy makes them useful for determining horizontal pressure gradients and their relation to wind ramp events, as well as the temporal variability of pressure associated with mountain wakes and waves. **Note different ASCII file formats for Goldendale (z04) and Walla Walla (z09) sites.**

  14. Microbarograph - ESRL Hi-Res Microbarograph, Wasco Airport - Raw Data

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    McCaffrey, Katherine

    High-precision barometers (Paroscientific 6000-16B-IS) are combined with Nishiyama-Bedard Quad Disk pressure probes, measuring pressure (mb) at the surface, nominally 2 m above ground level. Data are sampled at 20 Hz for potential studies of turbulence. The sensors' high accuracy makes them useful for determining horizontal pressure gradients and their relation to wind ramp events, as well as the temporal variability of pressure associated with mountain wakes and waves. **Note different ASCII file formats for Goldendale (z04) and Walla Walla (z09) sites.**

  15. Microbarograph - ESRL Hi-Res Microbarograph, Boardman - Raw Data

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    McCaffrey, Katherine

    High-precision barometers (Paroscientific 6000-16B-IS) are combined with Nishiyama-Bedard Quad Disk pressure probes, measuring pressure (mb) at the surface, nominally 2 m above ground level. Data are sampled at 20 Hz for potential studies of turbulence. The sensors' high accuracy makes them useful for determining horizontal pressure gradients and their relation to wind ramp events, as well as the temporal variability of pressure associated with mountain wakes and waves. **Note different ASCII file formats for Goldendale (z04) and Walla Walla (z09) sites.**

  16. Microbarograph - ESRL Hi-Res Microbarograph, John Day - Raw Data

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    McCaffrey, Katherine

    High-precision barometers (Paroscientific 6000-16B-IS) are combined with Nishiyama-Bedard Quad Disk pressure probes, measuring pressure (mb) at the surface, nominally 2 m above ground level. Data are sampled at 20 Hz for potential studies of turbulence. The sensors' high accuracy makes them useful for determining horizontal pressure gradients and their relation to wind ramp events, as well as the temporal variability of pressure associated with mountain wakes and waves. **Note different ASCII file formats for Goldendale (z04) and Walla Walla (z09) sites.**

  17. Microbarograph - ESRL Hi-Res Microbarograph, Hood River - Raw Data

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    McCaffrey, Katherine

    High-precision barometers (Paroscientific 6000-16B-IS) are combined with Nishiyama-Bedard Quad Disk pressure probes, measuring pressure (mb) at the surface, nominally 2 m above ground level. Data are sampled at 20 Hz for potential studies of turbulence. The sensors' high accuracy makes them useful for determining horizontal pressure gradients and their relation to wind ramp events, as well as the temporal variability of pressure associated with mountain wakes and waves. **Note different ASCII file formats for Goldendale (z04) and Walla Walla (z09) sites.**

  18. Microbarograph - ESRL Hi-Res Microbarograph, Umatilla - Reviewed Data

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    McCaffrey, Katherine

    High-precision barometers (Paroscientific 6000-16B-IS) are combined with Nishiyama-Bedard Quad Disk pressure probes, measuring pressure (mb) at the surface, nominally 2 m above ground level. Data are sampled at 20 Hz for potential studies of turbulence. The sensors' high accuracy makes them useful for determining horizontal pressure gradients and their relation to wind ramp events, as well as the temporal variability of pressure associated with mountain wakes and waves. **Note different ASCII file formats for Goldendale (z04) and Walla Walla (z09) sites.**

  19. Microbarograph - ESRL Hi-Res Microbarograph, Boardman - Reviewed Data

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    McCaffrey, Katherine

    High-precision barometers (Paroscientific 6000-16B-IS) are combined with Nishiyama-Bedard Quad Disk pressure probes, measuring pressure (mb) at the surface, nominally 2 m above ground level. Data are sampled at 20 Hz for potential studies of turbulence. The sensors' high accuracy makes them useful for determining horizontal pressure gradients and their relation to wind ramp events, as well as the temporal variability of pressure associated with mountain wakes and waves. **Note different ASCII file formats for Goldendale (z04) and Walla Walla (z09) sites.**

  20. Microbarograph - ESRL Hi-Res Microbarograph, Bonneville - Reviewed Data

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    McCaffrey, Katherine

    High-precision barometers (Paroscientific 6000-16B-IS) are combined with Nishiyama-Bedard Quad Disk pressure probes, measuring pressure (mb) at the surface, nominally 2 m above ground level. Data are sampled at 20 Hz for potential studies of turbulence. The sensors' high accuracy makes them useful for determining horizontal pressure gradients and their relation to wind ramp events, as well as the temporal variability of pressure associated with mountain wakes and waves. **Note different ASCII file formats for Goldendale (z04) and Walla Walla (z09) sites.**

  1. Microbarograph - ESRL Hi-Res Microbarograph, Bonneville - Raw Data

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    McCaffrey, Katherine

    High-precision barometers (Paroscientific 6000-16B-IS) are combined with Nishiyama-Bedard Quad Disk pressure probes, measuring pressure (mb) at the surface, nominally 2 m above ground level. Data are sampled at 20 Hz for potential studies of turbulence. The sensors' high accuracy makes them useful for determining horizontal pressure gradients and their relation to wind ramp events, as well as the temporal variability of pressure associated with mountain wakes and waves. **Note different ASCII file formats for Goldendale (z04) and Walla Walla (z09) sites.**

  2. Microbarograph - ESRL Hi-Res Microbarograph, Umatilla - Raw Data

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    McCaffrey, Katherine

    High-precision barometers (Paroscientific 6000-16B-IS) are combined with Nishiyama-Bedard Quad Disk pressure probes, measuring pressure (mb) at the surface, nominally 2 m above ground level. Data are sampled at 20 Hz for potential studies of turbulence. The sensors' high accuracy makes them useful for determining horizontal pressure gradients and their relation to wind ramp events, as well as the temporal variability of pressure associated with mountain wakes and waves. **Note different ASCII file formats for Goldendale (z04) and Walla Walla (z09) sites.**

  3. Microbarograph - ESRL Hi-Res Microbarograph, John Day - Reviewed Data

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    McCaffrey, Katherine

    High-precision barometers (Paroscientific 6000-16B-IS) are combined with Nishiyama-Bedard Quad Disk pressure probes, measuring pressure (mb) at the surface, nominally 2 m above ground level. Data are sampled at 20 Hz for potential studies of turbulence. The sensors' high accuracy makes them useful for determining horizontal pressure gradients and their relation to wind ramp events, as well as the temporal variability of pressure associated with mountain wakes and waves. **Note different ASCII file formats for Goldendale (z04) and Walla Walla (z09) sites.**

  4. Microbarograph - ESRL Hi-Res Microbarograph, Hood River - Reviewed Data

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    McCaffrey, Katherine

    High-precision barometers (Paroscientific 6000-16B-IS) are combined with Nishiyama-Bedard Quad Disk pressure probes, measuring pressure (mb) at the surface, nominally 2 m above ground level. Data are sampled at 20 Hz for potential studies of turbulence. The sensors' high accuracy makes them useful for determining horizontal pressure gradients and their relation to wind ramp events, as well as the temporal variability of pressure associated with mountain wakes and waves. **Note different ASCII file formats for Goldendale (z04) and Walla Walla (z09) sites.**

  5. A Superconducting Magnet UCN Trap for Precise Neutron Lifetime Measurements.

    PubMed

    Picker, R; Altarev, I; Bröcker, J; Gutsmiedl, E; Hartmann, J; Müller, A; Paul, S; Schott, W; Trinks, U; Zimmer, O

    2005-01-01

    Finite-element methods along with Monte Carlo simulations were used to design a magnetic storage device for ultracold neutrons (UCN) to measure their lifetime. A setup was determined which should make it possible to confine UCN with negligible losses and detect the protons emerging from β-decay with high efficiency: stacked superconducting solenoids create the magnetic storage field, an electrostatic extraction field inside the storage volume assures high proton collection efficiency. Alongside with the optimization of the magnetic and electrostatic design, the properties of the trap were investigated through extensive Monte Carlo simulation.

  6. Absolute spectrophotometry of Titan, Uranus, and Neptune 3500-10,500 A

    NASA Technical Reports Server (NTRS)

    Neff, J. S.; Humm, D. C.; Bergstralh, J. T.; Cochran, A. L.; Cochran, W. D.; Barker, E. S.; Tull, R. G.

    1984-01-01

    The present absolute measurements of Titan, Uranus and Neptune geometric albedo spectra in the 3500-10,500 A range have a resolution of about 7 A, together with high SNR, in virtue of the exceptional effeciency of the spectrograph and Reticon detector employed. The high precision and spectral resolution of the data, which are in excellent agreement with the Uranus albedo measurements of Lockwood et al. (1983), make possible quantitative measurements of the effects of Raman scattering by H2 in the Uranus and Neptune atmospheres.

  7. An open-source, extensible system for laboratory timing and control

    NASA Astrophysics Data System (ADS)

    Gaskell, Peter E.; Thorn, Jeremy J.; Alba, Sequoia; Steck, Daniel A.

    2009-11-01

    We describe a simple system for timing and control, which provides control of analog, digital, and radio-frequency signals. Our system differs from most common laboratory setups in that it is open source, built from off-the-shelf components, synchronized to a common and accurate clock, and connected over an Ethernet network. A simple bus architecture facilitates creating new and specialized devices with only moderate experience in circuit design. Each device operates independently, requiring only an Ethernet network connection to the controlling computer, a clock signal, and a trigger signal. This makes the system highly robust and scalable. The devices can all be connected to a single external clock, allowing synchronous operation of a large number of devices for situations requiring precise timing of many parallel control and acquisition channels. Provided an accurate enough clock, these devices are capable of triggering events separated by one day with near-microsecond precision. We have achieved precisions of ˜0.1 ppb (parts per 109) over 16 s.

  8. Precision Measurements of $$A_1^n$$ in the Deep Inelastic Regime

    DOE PAGES

    Parno, Diana; Flay, David; Posik, Matthew; ...

    2015-04-07

    We have performed precision measurements of the double-spin virtual-photon asymmetry A₁ on the neutron in the deep inelastic scattering regime, using an open-geometry, large-acceptance spectrometer and a longitudinally and transversely polarized ³He target. Our data cover a wide kinematic range 0.277 ≤ x ≤ 0.5480 at an average Q² value of 3.078 (GeV/c)², doubling the available high-precision neutron data in this x range. We have combined our results with world data on proton targets to make a leading-order extraction of the ratio of polarized-to-unpolarized parton distribution functions for up quarks and for down quarks in the same kinematic range. Ourmore » data are consistent with a previous observation of an View the MathML source A 1 n zero crossing near x=0.5. We find no evidence of a transition to a positive slope in (Δd+Δd¯)/(d+d¯) up to x=0.548.« less

  9. Academic medical centers as innovation ecosystems to address population -omics challenges in precision medicine.

    PubMed

    Silva, Patrick J; Schaibley, Valerie M; Ramos, Kenneth S

    2018-02-15

    While the promise of the Human Genome Project provided significant insights into the structure of the human genome, the complexities of disease at the individual level have made it difficult to utilize -omic information in clinical decision making. Some of the existing constraints have been minimized by technological advancements that have reduced the cost of sequencing to a rate far in excess of Moore's Law (a halving in cost per unit output every 18 months). The reduction in sequencing costs has made it economically feasible to create large data commons capturing the diversity of disease across populations. Until recently, these data have primarily been consumed in clinical research, but now increasingly being considered in clinical decision- making. Such advances are disrupting common diagnostic business models around which academic medical centers (AMCs) and molecular diagnostic companies have collaborated over the last decade. Proprietary biomarkers and patents on proprietary diagnostic content are no longer driving biomarker collaborations between industry and AMCs. Increasingly the scope of the data commons and biorepositories that AMCs can assemble through a nexus of academic and pharma collaborations is driving a virtuous cycle of precision medicine capabilities that make an AMC relevant and highly competitive. A rebalancing of proprietary strategies and open innovation strategies is warranted to enable institutional precision medicine asset portfolios. The scope of the AMC's clinical trial and research collaboration portfolios with industry are increasingly dependent on the currency of data, and less on patents. Intrapeneurial support of internal service offerings, clinical trials and clinical laboratory services for example, will be important new points of emphasis at the academic-industry interface. Streamlining these new models of industry collaboration for AMCs are a new area for technology transfer offices to offer partnerships and to add value beyond the traditional intellectual property offering.

  10. High precision wavefront control in point spread function engineering for single emitter localization

    NASA Astrophysics Data System (ADS)

    Siemons, M.; Hulleman, C. N.; Thorsen, R. Ø.; Smith, C. S.; Stallinga, S.

    2018-04-01

    Point Spread Function (PSF) engineering is used in single emitter localization to measure the emitter position in 3D and possibly other parameters such as the emission color or dipole orientation as well. Advanced PSF models such as spline fits to experimental PSFs or the vectorial PSF model can be used in the corresponding localization algorithms in order to model the intricate spot shape and deformations correctly. The complexity of the optical architecture and fit model makes PSF engineering approaches particularly sensitive to optical aberrations. Here, we present a calibration and alignment protocol for fluorescence microscopes equipped with a spatial light modulator (SLM) with the goal of establishing a wavefront error well below the diffraction limit for optimum application of complex engineered PSFs. We achieve high-precision wavefront control, to a level below 20 m$\\lambda$ wavefront aberration over a 30 minute time window after the calibration procedure, using a separate light path for calibrating the pixel-to-pixel variations of the SLM, and alignment of the SLM with respect to the optical axis and Fourier plane within 3 $\\mu$m ($x/y$) and 100 $\\mu$m ($z$) error. Aberrations are retrieved from a fit of the vectorial PSF model to a bead $z$-stack and compensated with a residual wavefront error comparable to the error of the SLM calibration step. This well-calibrated and corrected setup makes it possible to create complex `3D+$\\lambda$' PSFs that fit very well to the vectorial PSF model. Proof-of-principle bead experiments show precisions below 10~nm in $x$, $y$, and $\\lambda$, and below 20~nm in $z$ over an axial range of 1 $\\mu$m with 2000 signal photons and 12 background photons.

  11. Opto-mechanical system design of test system for near-infrared and visible target

    NASA Astrophysics Data System (ADS)

    Wang, Chunyan; Zhu, Guodong; Wang, Yuchao

    2014-12-01

    Guidance precision is the key indexes of the guided weapon shooting. The factors of guidance precision including: information processing precision, control system accuracy, laser irradiation accuracy and so on. The laser irradiation precision is an important factor. This paper aimed at the demand of the precision test of laser irradiator,and developed the laser precision test system. The system consists of modified cassegrain system, the wide range CCD camera, tracking turntable and industrial PC, and makes visible light and near infrared target imaging at the same time with a Near IR camera. Through the analysis of the design results, when it exposures the target of 1000 meters that the system measurement precision is43mm, fully meet the needs of the laser precision test.

  12. Working memory retrieval as a decision process

    PubMed Central

    Pearson, Benjamin; Raškevičius, Julius; Bays, Paul M.; Pertzov, Yoni; Husain, Masud

    2014-01-01

    Working memory (WM) is a core cognitive process fundamental to human behavior, yet the mechanisms underlying it remain highly controversial. Here we provide a new framework for understanding retrieval of information from WM, conceptualizing it as a decision based on the quality of internal evidence. Recent findings have demonstrated that precision of WM decreases with memory load. If WM retrieval uses a decision process that depends on memory quality, systematic changes in response time distribution should occur as a function of WM precision. We asked participants to view sample arrays and, after a delay, report the direction of change in location or orientation of a probe. As WM precision deteriorated with increasing memory load, retrieval time increased systematically. Crucially, the shape of reaction time distributions was consistent with a linear accumulator decision process. Varying either task relevance of items or maintenance duration influenced memory precision, with corresponding shifts in retrieval time. These results provide strong support for a decision-making account of WM retrieval based on noisy storage of items. Furthermore, they show that encoding, maintenance, and retrieval in WM need not be considered as separate processes, but may instead be conceptually unified as operations on the same noise-limited, neural representation. PMID:24492597

  13. Relative Sensor with 4(pi) Coverage for Formation Flying Missions

    NASA Technical Reports Server (NTRS)

    Tien, Jeffrey Y.; Purcell, George H., Jr.; Sirinivasan, Jeffrey M.; Young, Lawrence E.

    2004-01-01

    The Terrestrial Planet Finder (TPF) pre-project, an element of NASA's Origins program, is currently developing two architectures for a mission to search for earth-like planets around nearby stars. One of the architectures being developed is the Formation Flying Interferometer (FFI). The FFI is envisioned to consist of up to seven spacecraft (as many as six 'collectors' with IR telescopes, and a 'combiner') flying in precise formation within f 1 cm of pre-determined trajectories for synchronized observations. The spacecraft-to-spacecraft separations are variable between 20 m and 100 m or more during observations to support various configurations of the interferometer in the planet-finding mode. The challenges involved with TPF autonomous operations, ranging from formation acquisition and formation maneuvering to high precision formation control during science observations, are unprecedented. In this paper we discuss the development of the formation acquisition sensor, which uses novel modulation and duplexing schemes to enable fast signal acquisition, multiple-spacecraft operation, and mitigation of inherent jamming conditions, while providing precise formation sensing and integrated radar capability. This approach performs delay synthesis and carrier cycle ambiguity resolution to improve range measurement, and uses differential carrier cycle ambiguity resolution to make precise bearing angle measurements without calibration maneuvers.

  14. Relative Sensor with 4Pi Coverage for Formation Flying Missions

    NASA Technical Reports Server (NTRS)

    Tien, Jeffrey Y.; Purcell, George H., Jr.; Srinivasan, Jeffrey M.; Young, Lawrence E.

    2004-01-01

    The Terrestrial Planet Finder (TPF) pre-project, an element of NASA s Origins program, is currently developing two architectures for a mission to search for earth-like planets around nearby stars. One of the architectures being developed is the Formation Flying Interferometer (FFI). The FFI is envisioned to consist of up to seven spacecraft (as many as six "collectors" with IR telescopes, and a "combiner") flying in precise formation within +/-1 cm of pre-determined trajectories for synchronized observations. The spacecraft-to-spacecraft separations are variable between 20 m and 100 m or more during observations to support various configurations of the interferometer in the planet-finding mode. The challenges involved with TPF autonomous operations, ranging from formation acquisition and formation maneuvering to high precision formation control during science observations, are unprecedented. In this paper we discuss the development of the formation acquisition sensor, which uses novel modulation and duplexing schemes to enable fast signal acquisition, multiple-spacecraft operation, and mitigation of inherent jamming conditions, while providing precise formation sensing and integrated radar capability. This approach performs delay synthesis and carrier cycle ambiguity resolution to improve range measurement, and uses differential carrier cycle ambiguity resolution to make precise bearing angle measurements without calibration maneuvers.

  15. Working memory retrieval as a decision process.

    PubMed

    Pearson, Benjamin; Raskevicius, Julius; Bays, Paul M; Pertzov, Yoni; Husain, Masud

    2014-02-03

    Working memory (WM) is a core cognitive process fundamental to human behavior, yet the mechanisms underlying it remain highly controversial. Here we provide a new framework for understanding retrieval of information from WM, conceptualizing it as a decision based on the quality of internal evidence. Recent findings have demonstrated that precision of WM decreases with memory load. If WM retrieval uses a decision process that depends on memory quality, systematic changes in response time distribution should occur as a function of WM precision. We asked participants to view sample arrays and, after a delay, report the direction of change in location or orientation of a probe. As WM precision deteriorated with increasing memory load, retrieval time increased systematically. Crucially, the shape of reaction time distributions was consistent with a linear accumulator decision process. Varying either task relevance of items or maintenance duration influenced memory precision, with corresponding shifts in retrieval time. These results provide strong support for a decision-making account of WM retrieval based on noisy storage of items. Furthermore, they show that encoding, maintenance, and retrieval in WM need not be considered as separate processes, but may instead be conceptually unified as operations on the same noise-limited, neural representation.

  16. [Biobanking and the further development of precision medicine].

    PubMed

    Dahl, E

    2018-06-06

    Over the last 15 years, an estimated 3000 large centralized biobanks have been established worldwide, making important contributions to the further development of precision medicine. In many cases, these biobanks are affiliated with pathological institutes or work closely with them. In which translational research projects, and during which phases in the development of new drugs are human bioprobes being used and can their use be easily traced in the literature? PubMed, Internet research, and information from the German Biobank Alliance and the European initiative BBMRI-ERIC. High-quality biosamples from centralized biobanks are increasingly used in clinical research and development projects. Success stories, where bioprobes have contributed to the further development of precision medicine, are shown in this paper using among others the example of RET gene fusion discovery in lung cancer. Interestingly enough, many key publications in the field of precision medicine do not contain exact references to the biobanks involved. The importance of centralized biobanks in translational research and clinical development is constantly increasing. However, in order to ensure the acceptance and visibility of biobanks, their participation in success stories of biomedical progress must be systematically documented and published.

  17. Precision Distances with the Tip of the Red Giant Branch Method

    NASA Astrophysics Data System (ADS)

    Beaton, Rachael Lynn; Carnegie-Chicago Hubble Program Team

    2018-01-01

    The Carnegie-Chicago Hubble Program aims to construct a distance ladder that utilizes old stellar populations in the outskirts of galaxies to produce a high precision measurement of the Hubble Constant that is independent of Cepheids. The CCHP uses the tip of the red giant branch (TRGB) method, which is a statistical measurement technique that utilizes the termination of the red giant branch. Two innovations combine to make the TRGB a competitive route to the Hubble Constant (i) the large-scale measurement of trigonometric parallax by the Gaia mission and (ii) the development of both precise and accurate means of determining the TRGB in both nearby (~1 Mpc) and distant (~20 Mpc) galaxies. Here I will summarize our progress in developing these standardized techniques, focusing on both our edge-detection algorithm and our field selection strategy. Using these methods, the CCHP has determined equally precise (~2%) distances to galaxies in the Local Group (< 1 Mpc) and across the Local Volume (< 20 Mpc). The TRGB is, thus, an incredibly powerful and straightforward means to determine distances to galaxies of any Hubble Type and, thus, has enormous potential for putting any number of astrophyiscal phenomena on absolute units.

  18. Why pilots are least likely to get good decision making precisely when they need it most

    NASA Technical Reports Server (NTRS)

    Maher, John W.

    1991-01-01

    Studies of commercial aircraft incidents and accidents indicate that, in flight conditions not covered by standard operating procedures, as well as when the environment is saturated with information or unmanaged stress, cognitive shortcuts dominate aircrews' decisionmaking processes. Multidisciplinary research on such situations with high-fidelity simulators becomes critically important, as do psychometric tools which examine vigilance, personality resiliency before stressful conditions, and decisional and interpersonal mind-sets.

  19. Removing function model and experiments on ultrasonic polishing molding die

    NASA Astrophysics Data System (ADS)

    Huang, Qitai; Ni, Ying; Yu, Jingchi

    2010-10-01

    Low temperature glass molding technology is the main method on volume-producing high precision middle and small diameter optical cells in the future. While the accuracy of the molding die will effect the cell precision, so the high precision molding die development is one of the most important part of the low temperature glass molding technology. The molding die is manufactured from high rigid and crisp metal alloy, with the ultrasonic vibration character of high vibration frequency and concentrative energy distribution; abrasive particles will impact the rigid metal alloy surface with very high speed that will remove the material from the work piece. Ultrasonic can make the rigid metal alloy molding die controllable polishing and reduce the roughness and surface error. Different from other ultrasonic fabrication method, untouched ultrasonic polishing is applied on polish the molding die, that means the tool does not touch the work piece in the process of polishing. The abrasive particles vibrate around the balance position with high speed and frequency under the drive of ultrasonic vibration in the liquid medium and impact the workspace surface, the energy of abrasive particles come from ultrasonic vibration, while not from the direct hammer blow of the tool. So a nummular vibrator simple harmonic vibrates on an infinity plane surface is considered as a model of ultrasonic polishing working condition. According to Huygens theory the sound field distribution on a plane surface is analyzed and calculated, the tool removing function is also deduced from this distribution. Then the simple point ultrasonic polishing experiment is proceeded to certificate the theory validity.

  20. Pharmacogenomics and Global Precision Medicine in the Context of Adverse Drug Reactions: Top 10 Opportunities and Challenges for the Next Decade.

    PubMed

    Alessandrini, Marco; Chaudhry, Mamoonah; Dodgen, Tyren M; Pepper, Michael S

    2016-10-01

    In a move indicative of the enthusiastic support of precision medicine, the U.S. President Barack Obama announced the Precision Medicine Initiative in January 2015. The global precision medicine ecosystem is, thus, receiving generous support from the United States ($215 million), and numerous other governments have followed suit. In the context of precision medicine, drug treatment and prediction of its outcomes have been important for nearly six decades in the field of pharmacogenomics. The field offers an elegant solution for minimizing the effects and occurrence of adverse drug reactions (ADRs). The Clinical Pharmacogenetics Implementation Consortium (CPIC) plays an important role in this context, and it aims at specifically guiding the translation of clinically relevant and evidence-based pharmacogenomics research. In this forward-looking analysis, we make particular reference to several of the CPIC guidelines and their role in guiding the treatment of highly relevant diseases, namely cardiovascular disease, major depressive disorder, cancer, and human immunodeficiency virus, with a view to predicting and managing ADRs. In addition, we provide a list of the top 10 crosscutting opportunities and challenges facing the fields of precision medicine and pharmacogenomics, which have broad applicability independent of the drug class involved. Many of these opportunities and challenges pertain to infrastructure, study design, policy, and science culture in the early 21st century. Ultimately, rational pharmacogenomics study design and the acquisition of comprehensive phenotypic data that proportionately match the genomics data should be an imperative as we move forward toward global precision medicine.

  1. Pharmacogenomics and Global Precision Medicine in the Context of Adverse Drug Reactions: Top 10 Opportunities and Challenges for the Next Decade

    PubMed Central

    Alessandrini, Marco; Chaudhry, Mamoonah; Dodgen, Tyren M.

    2016-01-01

    Abstract In a move indicative of the enthusiastic support of precision medicine, the U.S. President Barack Obama announced the Precision Medicine Initiative in January 2015. The global precision medicine ecosystem is, thus, receiving generous support from the United States ($215 million), and numerous other governments have followed suit. In the context of precision medicine, drug treatment and prediction of its outcomes have been important for nearly six decades in the field of pharmacogenomics. The field offers an elegant solution for minimizing the effects and occurrence of adverse drug reactions (ADRs). The Clinical Pharmacogenetics Implementation Consortium (CPIC) plays an important role in this context, and it aims at specifically guiding the translation of clinically relevant and evidence-based pharmacogenomics research. In this forward-looking analysis, we make particular reference to several of the CPIC guidelines and their role in guiding the treatment of highly relevant diseases, namely cardiovascular disease, major depressive disorder, cancer, and human immunodeficiency virus, with a view to predicting and managing ADRs. In addition, we provide a list of the top 10 crosscutting opportunities and challenges facing the fields of precision medicine and pharmacogenomics, which have broad applicability independent of the drug class involved. Many of these opportunities and challenges pertain to infrastructure, study design, policy, and science culture in the early 21st century. Ultimately, rational pharmacogenomics study design and the acquisition of comprehensive phenotypic data that proportionately match the genomics data should be an imperative as we move forward toward global precision medicine. PMID:27643672

  2. Budget impact and cost-effectiveness: can we afford precision medicine in oncology?

    PubMed

    Doble, Brett

    2016-01-01

    Over the past decade there have been remarkable advancements in the understanding of the molecular underpinnings of malignancy. Methods of testing capable of elucidating patients' molecular profiles are now readily available and there is an increased desire to incorporate the information derived from such tests into treatment selection for cancer patients. This has led to more appropriate application of existing treatments as well as the development of a number of innovative and highly effective treatments or what is known collectively as precision medicine. The impact that precision medicine will have on health outcomes is uncertain, as are the costs it will incur. There is, therefore, a need to develop economic evidence and appropriate methods of evaluation to support its implementation to ensure the resources allocated to these approaches are affordable and offer value for money. The market for precision medicine in oncology continues to rapidly expand, placing an increased pressure on reimbursement decision-makers to consider the value and opportunity cost of funding such approaches to care. The benefits of molecular testing can be complex and difficult to evaluate given currently available economic methods, potentially causing a distorted appreciation of their value. Funding decisions of precision medicine will also have far-reaching implications, requiring the consideration of both patient and public perspectives in decision-making. Recommendations to improve the value proposition of precision medicine are, therefore, provided with the hopes of facilitating a better understanding of its impact on outcomes and the overall health budget.

  3. Measurement of latent cognitive abilities involved in concept identification learning.

    PubMed

    Thomas, Michael L; Brown, Gregory G; Gur, Ruben C; Moore, Tyler M; Patt, Virginie M; Nock, Matthew K; Naifeh, James A; Heeringa, Steven; Ursano, Robert J; Stein, Murray B

    2015-01-01

    We used cognitive and psychometric modeling techniques to evaluate the construct validity and measurement precision of latent cognitive abilities measured by a test of concept identification learning: the Penn Conditional Exclusion Test (PCET). Item response theory parameters were embedded within classic associative- and hypothesis-based Markov learning models and were fitted to 35,553 Army soldiers' PCET data from the Army Study to Assess Risk and Resilience in Servicemembers (Army STARRS). Data were consistent with a hypothesis-testing model with multiple latent abilities-abstraction and set shifting. Latent abstraction ability was positively correlated with number of concepts learned, and latent set-shifting ability was negatively correlated with number of perseverative errors, supporting the construct validity of the two parameters. Abstraction was most precisely assessed for participants with abilities ranging from 1.5 standard deviations below the mean to the mean itself. Measurement of set shifting was acceptably precise only for participants making a high number of perseverative errors. The PCET precisely measures latent abstraction ability in the Army STARRS sample, especially within the range of mildly impaired to average ability. This precision pattern is ideal for a test developed to measure cognitive impairment as opposed to cognitive strength. The PCET also measures latent set-shifting ability, but reliable assessment is limited to the impaired range of ability, reflecting that perseverative errors are rare among cognitively healthy adults. Integrating cognitive and psychometric models can provide information about construct validity and measurement precision within a single analytical framework.

  4. Eco-Environment Status Evaluation and Change Analysis of Qinghai Based on National Geographic Conditions Census Data

    NASA Astrophysics Data System (ADS)

    Zheng, M.; Zhu, M.; Wang, Y.; Xu, C.; Yang, H.

    2018-04-01

    As the headstream of the Yellow River, the Yangtze River and the Lantsang River, located in the hinterland of Qinghai-Tibet Plateau, Qinghai province is hugely significant for ecosystem as well as for ecological security and sustainable development in China. With the accomplishment of the first national geographic condition census, the frequent monitoring has begun. The classification indicators of the census and monitoring data are highly correlated with Technical Criterion for Ecosystem Status Evaluation released by Ministry of Environmental Protection in 2015. Based on three years' geographic conditions data (2014-2016), Landsat-8 images and thematic data (water resource, pollution emissions, meteorological data, soil erosion, etc.), a multi-years and high-precision eco-environment status evaluation and spatiotemporal change analysis of Qinghai province has been researched on the basis of Technical Criterion for Ecosystem Status Evaluation in this paper. Unlike the evaluation implemented by environmental protection department, the evaluation unit in this paper is town rather than county. The evaluation result shows that the eco-environment status in Qinghai is generally in a fine condition, and has significant regional differences. The eco-environment status evaluation based on national geographic conditions census and monitoring data can improve both the time and space precision. The eco-environment status with high space precise and multi-indices is a key basis for environment protection decision-making.

  5. Terrain matching image pre-process and its format transform in autonomous underwater navigation

    NASA Astrophysics Data System (ADS)

    Cao, Xuejun; Zhang, Feizhou; Yang, Dongkai; Yang, Bogang

    2007-06-01

    Underwater passive navigation technology is one of the important development orientations in the field of modern navigation. With the advantage of high self-determination, stealth at sea, anti-jamming and high precision, passive navigation is completely meet with actual navigation requirements. Therefore passive navigation has become a specific navigating method for underwater vehicles. The scientists and researchers in the navigating field paid more attention to it. The underwater passive navigation can provide accurate navigation information with main Inertial Navigation System (INS) for a long period, such as location and speed. Along with the development of micro-electronics technology, the navigation of AUV is given priority to INS assisted with other navigation methods, such as terrain matching navigation. It can provide navigation ability for a long period, correct the errors of INS and make AUV not emerge from the seabed termly. With terrain matching navigation technique, in the assistance of digital charts and ocean geographical characteristics sensors, we carry through underwater image matching assistant navigation to obtain the higher location precision, therefore it is content with the requirement of underwater, long-term, high precision and all-weather of the navigation system for Autonomous Underwater Vehicles. Tertian-assistant navigation (TAN) is directly dependent on the image information (map information) in the navigating field to assist the primary navigation system according to the path appointed in advance. In TAN, a factor coordinative important with the system operation is precision and practicability of the storable images and the database which produce the image data. If the data used for characteristics are not suitable, the system navigation precision will be low. Comparing with terrain matching assistant navigation system, image matching navigation system is a kind of high precision and low cost assistant navigation system, and its matching precision directly influences the final precision of integrated navigation system. Image matching assistant navigation is spatially matching and aiming at two underwater scenery images coming from two different sensors matriculating of the same scenery in order to confirm the relative displacement of the two images. In this way, we can obtain the vehicle's location in fiducial image known geographical relation, and the precise location information given from image matching location is transmitted to INS to eliminate its location error and greatly enhance the navigation precision of vehicle. Digital image data analysis and processing of image matching in underwater passive navigation is important. In regard to underwater geographic data analysis, we focus on the acquirement, disposal, analysis, expression and measurement of database information. These analysis items structure one of the important contents of underwater terrain matching and are propitious to know the seabed terrain configuration of navigation areas so that the best advantageous seabed terrain district and dependable navigation algorithm can be selected. In this way, we can improve the precision and reliability of terrain assistant navigation system. The pre-process and format transformation of digital image during underwater image matching are expatiated in this paper. The information of the terrain status in navigation areas need further study to provide the reliable data terrain characteristic and underwater overcast for navigation. Through realizing the choice of sea route, danger district prediction and navigating algorithm analysis, TAN can obtain more high location precision and probability, hence provide technological support for image matching of underwater passive navigation.

  6. Electrochemical Impedance Spectrometer with an Environmental Chamber for Rapid Screening of New Precise Copolymers

    DTIC Science & Technology

    2017-10-07

    polymerization to make linear polyethylenes with carboxylic acid groups at precise intervals along the polymer . Precise acid- containing polymers provide...acid polyethylene and the a polymerized ionic liquids based on cyclopropenium. The instrument is also be used to study polymer segmental dynamics...Advances in batteries, fuel cells, and permselective membranes are materials limited. New acid- and ion-containing polymers must be designed and

  7. Improved DORIS accuracy for precise orbit determination and geodesy

    NASA Technical Reports Server (NTRS)

    Willis, Pascal; Jayles, Christian; Tavernier, Gilles

    2004-01-01

    In 2001 and 2002, 3 more DORIS satellites were launched. Since then, all DORIS results have been significantly improved. For precise orbit determination, 20 cm are now available in real-time with DIODE and 1.5 to 2 cm in post-processing. For geodesy, 1 cm precision can now be achieved regularly every week, making now DORIS an active part of a Global Observing System for Geodesy through the IDS.

  8. Note: A rigid piezo motor with large output force and an effective method to reduce sliding friction force.

    PubMed

    Guo, Ying; Hou, Yubin; Lu, Qingyou

    2014-05-01

    We present a completely practical TunaDrive piezo motor. It consists of a central piezo stack sandwiched by two arm piezo stacks and two leg piezo stacks, respectively, which is then sandwiched and spring-clamped by a pair of parallel polished sapphire rods. It works by alternatively fast expanding and contracting the arm/leg stacks while slowly expanding/contracting the central stack simultaneously. The key point is that sufficiently fast expanding and contracting a limb stack can make its two sliding friction forces well cancel, resulting in the total sliding friction force is <10% of the total static friction force, which can help increase output force greatly. The piezo motor's high compactness, precision, and output force make it perfect in building a high-quality harsh-condition (vibration resistant) atomic resolution scanning probe microscope.

  9. How training citizen scientists affects the accuracy and precision of phenological data

    NASA Astrophysics Data System (ADS)

    Feldman, Richard E.; Žemaitė, Irma; Miller-Rushing, Abraham J.

    2018-05-01

    Monitoring plant and animal phenology is a critical step to anticipating and predicting changes in species interactions and biodiversity. Because phenology necessarily involves frequent and repeated observations over time, citizen scientists have become a vital part of collecting phenological data. However, there is still concern over the accuracy and precision of citizen science data. It is possible that training citizen scientists can improve data quality though there are few comparisons of trained and untrained citizen scientists in the ability of each to accurately and precisely measure phenology. We assessed how three types of observers—experts, trained citizen scientists that make repeated observations, and untrained citizen scientists making once-per-year observations—differ in quantifying temporal change in flower and fruit abundance of American mountain ash trees (Sorbus americana Marsh.) and arthropods in Acadia National Park, Maine, USA. We found that trained more so than untrained citizen science observers over- or under-estimated abundances leading to precise but inaccurate characterizations of phenological patterns. Our results suggest a new type of bias induced by repeated observations: A type of learning takes place that reduces the independence of observations taken on different trees or different dates. Thus, in this and many other cases, having individuals make one-off observations of marked plants may produce data as good if not better than individuals making repeated observations. For citizen science programs related to phenology, our results underscore the importance of (a) attracting the most number of observers possible even if they only make one observation, (b) producing easy-to-use and informative data sheets, and (c) carefully planning effective training programs that are, perhaps, repeated at different points during the data collection period.

  10. How training citizen scientists affects the accuracy and precision of phenological data.

    PubMed

    Feldman, Richard E; Žemaitė, Irma; Miller-Rushing, Abraham J

    2018-05-07

    Monitoring plant and animal phenology is a critical step to anticipating and predicting changes in species interactions and biodiversity. Because phenology necessarily involves frequent and repeated observations over time, citizen scientists have become a vital part of collecting phenological data. However, there is still concern over the accuracy and precision of citizen science data. It is possible that training citizen scientists can improve data quality though there are few comparisons of trained and untrained citizen scientists in the ability of each to accurately and precisely measure phenology. We assessed how three types of observers-experts, trained citizen scientists that make repeated observations, and untrained citizen scientists making once-per-year observations-differ in quantifying temporal change in flower and fruit abundance of American mountain ash trees (Sorbus americana Marsh.) and arthropods in Acadia National Park, Maine, USA. We found that trained more so than untrained citizen science observers over- or under-estimated abundances leading to precise but inaccurate characterizations of phenological patterns. Our results suggest a new type of bias induced by repeated observations: A type of learning takes place that reduces the independence of observations taken on different trees or different dates. Thus, in this and many other cases, having individuals make one-off observations of marked plants may produce data as good if not better than individuals making repeated observations. For citizen science programs related to phenology, our results underscore the importance of (a) attracting the most number of observers possible even if they only make one observation, (b) producing easy-to-use and informative data sheets, and (c) carefully planning effective training programs that are, perhaps, repeated at different points during the data collection period.

  11. Accuracy, precision, and economic efficiency for three methods of thrips (Thysanoptera: Thripidae) population density assessment.

    PubMed

    Sutherland, Andrew M; Parrella, Michael P

    2011-08-01

    Western flower thrips, Frankliniella occidentalis (Pergande) (Thysanoptera: Thripidae), is a major horticultural pest and an important vector of plant viruses in many parts of the world. Methods for assessing thrips population density for pest management decision support are often inaccurate or imprecise due to thrips' positive thigmotaxis, small size, and naturally aggregated populations. Two established methods, flower tapping and an alcohol wash, were compared with a novel method, plant desiccation coupled with passive trapping, using accuracy, precision and economic efficiency as comparative variables. Observed accuracy was statistically similar and low (37.8-53.6%) for all three methods. Flower tapping was the least expensive method, in terms of person-hours, whereas the alcohol wash method was the most expensive. Precision, expressed by relative variation, depended on location within the greenhouse, location on greenhouse benches, and the sampling week, but it was generally highest for the flower tapping and desiccation methods. Economic efficiency, expressed by relative net precision, was highest for the flower tapping method and lowest for the alcohol wash method. Advantages and disadvantages are discussed for all three methods used. If relative density assessment methods such as these can all be assumed to accurately estimate a constant proportion of absolute density, then high precision becomes the methodological goal in terms of measuring insect population density, decision making for pest management, and pesticide efficacy assessments.

  12. Emulation applied to reliability analysis of reconfigurable, highly reliable, fault-tolerant computing systems

    NASA Technical Reports Server (NTRS)

    Migneault, G. E.

    1979-01-01

    Emulation techniques applied to the analysis of the reliability of highly reliable computer systems for future commercial aircraft are described. The lack of credible precision in reliability estimates obtained by analytical modeling techniques is first established. The difficulty is shown to be an unavoidable consequence of: (1) a high reliability requirement so demanding as to make system evaluation by use testing infeasible; (2) a complex system design technique, fault tolerance; (3) system reliability dominated by errors due to flaws in the system definition; and (4) elaborate analytical modeling techniques whose precision outputs are quite sensitive to errors of approximation in their input data. Next, the technique of emulation is described, indicating how its input is a simple description of the logical structure of a system and its output is the consequent behavior. Use of emulation techniques is discussed for pseudo-testing systems to evaluate bounds on the parameter values needed for the analytical techniques. Finally an illustrative example is presented to demonstrate from actual use the promise of the proposed application of emulation.

  13. Measurement device for high-precision spectral transmittance of solar blind filter

    NASA Astrophysics Data System (ADS)

    Wang, Yan; Qian, Yunsheng; Lv, Yang; Feng, Cheng; Liu, Jian

    2017-02-01

    In order to measure spectral transmittance of solar-blind filter ranging from ultraviolet to visible light accurately, a high-precision filter transmittance measuring system based on the ultraviolet photomultiplier is developed. The calibration method is mainly used to measure transmittance in this system, which mainly consists of an ultraviolet photomultiplier as core of the system and a lock-in amplifier combined with an optical modulator as the aided measurement for the system. The ultraviolet photomultiplier can amplify the current signal through the filter and have the characteristics of low dark current and high luminance gain. The optical modulator and the lock-in amplifier can obtain the signal from the photomultiplier and inhibit dark noise and spurious signal effectively. Through these two parts, the low light passing through the filters can be detected and we can calculate the transmittance by the optical power detected. Based on the proposed system, the limit detection of the transmittance can reach 10-12, while the result of the conventional approach is merely 10-6. Therefore, the system can make an effective assessment of solar blind ultraviolet filters.

  14. Off-plane x-ray reflection grating fabrication

    NASA Astrophysics Data System (ADS)

    Peterson, Thomas J.; DeRoo, Casey T.; Marlowe, Hannah; McEntaffer, Randall L.; Miles, Drew M.; Tutt, James H.; Schultz, Ted B.

    2015-09-01

    Off-plane X-ray diffraction gratings with precision groove profiles at the submicron scale will be used in next generation X-ray spectrometers. Such gratings will be used on a current NASA suborbital rocket mission, the Off-plane Grating Rocket Experiment (OGRE), and have application for future grating missions. The fabrication of these gratings does not come without challenges. High performance off-plane gratings must be fabricated with precise radial grating patterns, optically at surfaces, and specific facet angles. Such gratings can be made using a series of common micro-fabrication techniques. The resulting process is highly customizable, making it useful for a variety of different mission architectures. In this paper, we detail the fabrication method used to produce high performance off-plane gratings and report the results of a preliminary qualification test of a grating fabricated in this manner. The grating was tested in the off-plane `Littrow' configuration, for which the grating is most efficient for a given diffraction order, and found to achieve 42% relative efficiency in the blaze order with respect to all diffracted light.

  15. Flight test experience with pilot-induced-oscillation suppressor filters

    NASA Technical Reports Server (NTRS)

    Shafer, M. F.; Smith, R. E.; Stewart, J. F.; Bailey, R. E.

    1983-01-01

    Digital flight control systems are popular for their flexibility, reliability, and power; however, their use sometimes results in deficient handling qualities, including pilot-induced oscillation (PIO), which can require extensive redesign of the control system. When redesign is not immediately possible, temporary solutions, such as the PIO suppression (PIOS) filter developed for the Space Shuttle, have been proposed. To determine the effectiveness of such PIOS filters on more conventional, high-performance aircraft, three experiments were performed using the NASA F-8 digital fly-by-wire and USAF/Calspan NT-33 variable-stability aircraft. Two types of PIOS filters were evaluated, using high-gain, precision tasks (close formation, probe-and-drogue refueling, and precision touch-and-go landing) with a time delay or a first-order lag added to make the aircraft prone to PIO. Various configurations of the PIOS filter were evaluated in the flight programs, and most of the PIOS filter configurations reduced the occurrence of PIOs and improved the handling qualities of the PIO-prone aircraft. These experiments also confirmed the influence of high-gain tasks and excessive control system time delay in evoking pilot-induced oscillations.

  16. Flight test experience with pilot-induced-oscillation suppression filters

    NASA Technical Reports Server (NTRS)

    Shafer, M. F.; Smith, R. E.; Stewart, J. F.; Bailey, R. E.

    1984-01-01

    Digital flight control systems are popular for their flexibility, reliability, and power; however, their use sometimes results in deficient handling qualities, including pilot-induced oscillation (PIO), which can require extensive redesign of the control system. When redesign is not immediately possible, temporary solutions, such as the PIO suppression (PIOS) filter developed for the Space Shuttle, have been proposed. To determine the effectiveness of such PIOS filters on more conventional, high-performance aircraft, three experiments were performed using the NASA F-8 digital fly-by-wire and USAF/Calspan NT-33 variable-stability aircraft. Two types of PIOS filters were evaluated, using high-gain, precision tasks (close formation, probe-and-drogue refueling, and precision touch-and-go landing) with a time delay or a first-order lag added to make the aircraft prone to PIO. Various configurations of the PIOS filter were evaluated in the flight programs, and most of the PIOS filter configurations reduced the occurrence of PIOs and improved the handling qualities of the PIO-prone aircraft. These experiments also confirmed the influence of high-gain tasks and excessive control system time delay in evoking pilot-induced oscillations.

  17. Measurement of snow depth distribution in the Kamikochi-Azusa river basin using an airborne laser scanning

    NASA Astrophysics Data System (ADS)

    Suzuki, K.; Sasaki, A.

    2013-12-01

    In the Japanese Alps region, large amounts of precipitation in the form of snow constitute a more important water resource than rain. During the winter, precipitation that is deposited as snowfall accumulates in the river basins, and it forms natural dams known as 'white dams.' A quantitative understanding of snow depth distribution in these mountainous areas is important not only for evaluating water resource volume, but also for understanding the effects of snow in terms of its impact on landforms and its effect on the distribution of vegetation. However, it is not easy to perform a quantitative evaluation of snow depth distribution in mountainous areas. Several methods have been proposed for clarifying snow depth distribution. The most widely used of these is a method of inserting a sounding rod into the snow to measure its depth at each geographic position. Another method is to dig a trench in the snow and then perform an observational measurement of the side of the trench. These methods enable accurate measurement of the snow depth; however, when the snow is several meters deep, the methods may be limited by the measuring capacity of the equipment, or by the time restrictions of the survey. For these reasons, wide area measurement of the spatial distribution of snow is very difficult, and it is not suitable for investigating snow depth distribution in river basins. There is a method of using ultrasonics or radar to measure the depth of snow and to make observations of snow depth at certain positions. This method offers high measurement precision and high time resolution at the observation points. However, for observations in areas of very deep snow, it becomes technically difficult to install the equipment, and it is difficult to make a large number of installations to cover a wide area. There are also methods of indirectly measuring snow depth. One of these is to use aerial photographs taken when there is no snow cover and when there is snow cover, draw contour lines, and then use the difference between them to clarify the snow depth. This method allows researchers to grasp the snow depth over a wide area, but it needs to be made more precise if it is to incorporate high-precision information on equivalent elevation points on the snow surface. In recent years, a measurement technology has been developed that uses laser scanners mounted on aircraft. This method enables researchers to obtain ground surface coordinate data with high precision over a wide area from the air. Using such a scanner to measure the ground surface during snow coverage and during no snow coverage, and then finding the differences between the surface elevations, has made it possible to ascertain snow depth with high precision. Airborne laser measurement enables high-precision measurements over a wide area and in a short amount of time, and measurements can be made regardless of geographical factors such as sloping ground. As such, it enables measurement of snow depth distribution over a wide area without having to worry about the undulations of the land. In this study, airborne laser scanning was carried out on the snow surface in the upstream region of the Kamikochi-Azusa River in Japan on March 29, 2012, in order to clarify the snow depth distribution.

  18. Improving precision of forage yield trials: A case study

    USDA-ARS?s Scientific Manuscript database

    Field-based agronomic and genetic research relies heavily on the data generated from field evaluations. Therefore, it is imperative to optimize the precision of yield estimates in cultivar evaluation trials to make reliable selections. Experimental error in yield trials is sensitive to several facto...

  19. Dual-stimuli responsive and reversibly activatable theranostic nanoprobe for precision tumor-targeting and fluorescence-guided photothermal therapy

    NASA Astrophysics Data System (ADS)

    Zhao, Xu; Yang, Cheng-Xiong; Chen, Li-Gong; Yan, Xiu-Ping

    2017-05-01

    The integrated functions of diagnostics and therapeutics make theranostics great potential for personalized medicine. Stimulus-responsive therapy allows spatial control of therapeutic effect only in the site of interest, and offers promising opportunities for imaging-guided precision therapy. However, the imaging strategies in previous stimulus-responsive therapies are `always on' or irreversible `turn on' modality, resulting in poor signal-to-noise ratios or even `false positive' results. Here we show the design of dual-stimuli-responsive and reversibly activatable nanoprobe for precision tumour-targeting and fluorescence-guided photothermal therapy. We fabricate the nanoprobe from asymmetric cyanine and glycosyl-functionalized gold nanorods (AuNRs) with matrix metalloproteinases (MMPs)-specific peptide as a linker to achieve MMPs/pH synergistic and pH reversible activation. The unique activation and glycosyl targetibility makes the nanoprobe bright only in tumour sites with negligible background, while AuNRs and asymmetric cyanine give synergistic photothermal effect. This work paves the way to designing efficient nanoprobes for precision theranostics.

  20. Space Science

    NASA Image and Video Library

    1997-10-01

    This king-size copper disk, manufactured at the Space Optics Manufacturing and Technology Center (SOMTC) at the Marshall Space Flight Center (MSFC), is a special mold for making high resolution monitor screens. This master mold will be used to make several other molds, each capable of forming hundreds of screens that have a type of lens called a Fresnel lens. Weighing much less than conventional optics, Fresnel lenses have multiple concentric grooves, each formed to a precise angle, that together create the curvature needed to focus and project images. MSFC leads NASA's space optics manufacturing technology development as a technology leader for diamond turning. The machine used to manufacture this mold is among many one-of-a-kind pieces of equipment of MSFC's SOMTC.

  1. Axion dark matter and the Lattice

    NASA Astrophysics Data System (ADS)

    Moore, Guy

    2018-03-01

    First I will review the QCD theta problem and the Peccei-Quinn solution, with its new particle, the axion. I will review the possibility of the axion as dark matter. If PQ symmetry was restored at some point in the hot early Universe, it should be possible to make a definite prediction for the axion mass if it constitutes the Dark Matter. I will describe progress on one issue needed to make this prediction - the dynamics of axionic string-wall networks and how they produce axions. Then I will discuss the sensitivity of the calculation to the high temperature QCD topological susceptibility. My emphasis is on what temperature range is important, and what level of precision is needed.

  2. EXPLORING DATA-DRIVEN SPECTRAL MODELS FOR APOGEE M DWARFS

    NASA Astrophysics Data System (ADS)

    Lua Birky, Jessica; Hogg, David; Burgasser, Adam J.; Jessica Birky

    2018-01-01

    The Cannon (Ness et al. 2015; Casey et al. 2016) is a flexible, data-driven spectral modeling and parameter inference framework, demonstrated on high-resolution Apache Point Galactic Evolution Experiment (APOGEE; λ/Δλ~22,500, 1.5-1.7µm) spectra of giant stars to estimate stellar labels (Teff, logg, [Fe/H], and chemical abundances) to precisions higher than the model-grid pipeline. The lack of reliable stellar parameters reported by the APOGEE pipeline for temperatures less than ~3550K, motivates extension of this approach to M dwarf stars. Using a training set of 51 M dwarfs with spectral types ranging M0-M9 obtained from SDSS optical spectra, we demonstrate that the Cannon can infer spectral types to a precision of +/-0.6 types, making it an effective tool for classifying high-resolution near-infrared spectra. We discuss the potential for extending this work to determine the physical stellar labels Teff, logg, and [Fe/H].This work is supported by the SDSS Faculty and Student (FAST) initiative.

  3. Extracting Related Words from Anchor Text Clusters by Focusing on the Page Designer's Intention

    NASA Astrophysics Data System (ADS)

    Liu, Jianquan; Chen, Hanxiong; Furuse, Kazutaka; Ohbo, Nobuo

    Approaches for extracting related words (terms) by co-occurrence work poorly sometimes. Two words frequently co-occurring in the same documents are considered related. However, they may not relate at all because they would have no common meanings nor similar semantics. We address this problem by considering the page designer’s intention and propose a new model to extract related words. Our approach is based on the idea that the web page designers usually make the correlative hyperlinks appear in close zone on the browser. We developed a browser-based crawler to collect “geographically” near hyperlinks, then by clustering these hyperlinks based on their pixel coordinates, we extract related words which can well reflect the designer’s intention. Experimental results show that our method can represent the intention of the web page designer in extremely high precision. Moreover, the experiments indicate that our extracting method can obtain related words in a high average precision.

  4. High-precision measurements of wetland sediment elevation. II The rod surface elevation table

    USGS Publications Warehouse

    Cahoon, D.R.; Lynch, J.C.; Perez, B.C.; Segura, B.; Holland, R.D.; Stelly, C.; Stephenson, G.; Hensel, P.

    2002-01-01

    A new high-precision device for measuring sediment elevation in emergent and shallow water wetland systems is described. The rod surface-elevation table (RSET) is a balanced, lightweight mechanical leveling device that attaches to both shallow ( 1 m in order to be stable. The pipe is driven to refusal but typically to a depth shallower than the rod bench mark because of greater surface resistance of the pipe. Thus, the RSET makes it possible to partition change in sediment elevation over shallower (e.g., the root zone) and deeper depths of the sediment profile than is possible with the SET. The confidence intervals for the height of an individual pin measured by two different operators with the RSET under laboratory conditions were A? 1.0 and A? 1.5 mm. Under field conditions, confidence intervals for the measured height of an individual pin ranged from A? 1.3 mm in a mangrove forest up to A? 4.3 mm in a salt marsh.

  5. Precise Ages for the Benchmark Brown Dwarfs HD 19467 B and HD 4747 B

    NASA Astrophysics Data System (ADS)

    Wood, Charlotte; Boyajian, Tabetha; Crepp, Justin; von Braun, Kaspar; Brewer, John; Schaefer, Gail; Adams, Arthur; White, Tim

    2018-01-01

    Large uncertainty in the age of brown dwarfs, stemming from a mass-age degeneracy, makes it difficult to constrain substellar evolutionary models. To break the degeneracy, we need ''benchmark" brown dwarfs (found in binary systems) whose ages can be determined independent of their masses. HD~19467~B and HD~4747~B are two benchmark brown dwarfs detected through the TRENDS (TaRgeting bENchmark objects with Doppler Spectroscopy) high-contrast imaging program for which we have dynamical mass measurements. To constrain their ages independently through isochronal analysis, we measured the radii of the host stars with interferometry using the Center for High Angular Resolution Astronomy (CHARA) Array. Assuming the brown dwarfs have the same ages as their host stars, we use these results to distinguish between several substellar evolutionary models. In this poster, we present new age estimates for HD~19467 and HD~4747 that are more accurate and precise and show our preliminary comparisons to cooling models.

  6. Thermal expansion as a precision actuator

    NASA Astrophysics Data System (ADS)

    Miller, Chris; Montgomery, David; Black, Martin; Schnetler, Hermine

    2016-07-01

    The UK ATC has developed a novel thermal actuator design as part of an OPTICON project focusing on the development of a Freeform Active Mirror Element (FAME). The actuator uses the well understood concept of thermal expansion to generate the required force and displacement. As heat is applied to the actuator material it expands linearly. A resistance temperature device (RTD) is embedded in the centre of the actuator and is used both as a heater and a sensor. The RTD temperature is controlled electronically by injecting a varying amount of current into the device whilst measuring the voltage across it. Temperature control of the RTD has been achieved to within 0.01°C. A 3D printed version of the actuator is currently being used at the ATC to deform a mirror but it has several advantages that may make it suitable to other applications. The actuator is cheap to produce whilst obtaining a high accuracy and repeatability. The actuator design would be suitable for applications requiring large numbers of actuators with high precision.

  7. The generation of higher-order Laguerre-Gauss optical beams for high-precision interferometry.

    PubMed

    Carbone, Ludovico; Fulda, Paul; Bond, Charlotte; Brueckner, Frank; Brown, Daniel; Wang, Mengyao; Lodhia, Deepali; Palmer, Rebecca; Freise, Andreas

    2013-08-12

    Thermal noise in high-reflectivity mirrors is a major impediment for several types of high-precision interferometric experiments that aim to reach the standard quantum limit or to cool mechanical systems to their quantum ground state. This is for example the case of future gravitational wave observatories, whose sensitivity to gravitational wave signals is expected to be limited in the most sensitive frequency band, by atomic vibration of their mirror masses. One promising approach being pursued to overcome this limitation is to employ higher-order Laguerre-Gauss (LG) optical beams in place of the conventionally used fundamental mode. Owing to their more homogeneous light intensity distribution these beams average more effectively over the thermally driven fluctuations of the mirror surface, which in turn reduces the uncertainty in the mirror position sensed by the laser light. We demonstrate a promising method to generate higher-order LG beams by shaping a fundamental Gaussian beam with the help of diffractive optical elements. We show that with conventional sensing and control techniques that are known for stabilizing fundamental laser beams, higher-order LG modes can be purified and stabilized just as well at a comparably high level. A set of diagnostic tools allows us to control and tailor the properties of generated LG beams. This enabled us to produce an LG beam with the highest purity reported to date. The demonstrated compatibility of higher-order LG modes with standard interferometry techniques and with the use of standard spherical optics makes them an ideal candidate for application in a future generation of high-precision interferometry.

  8. Laser beam distribution system for the HiLASE Center

    NASA Astrophysics Data System (ADS)

    Macúchová, Karolina; Heřmánek, Jan; Kaufman, Jan; Muresan, Mihai-George; Růžička, Jan; Řeháková, Martina; Divoký, Martin; Švandrlík, Luděk.; Mocek, Tomáś

    2017-12-01

    We report recent progress in design and testing of a distribution system for high-power laser beam delivery developed within the HiLASE project of the IOP in the Czech Republic. Laser beam distribution system is a technical system allowing safe and precise distribution of different laser beams from laboratories to several experimental stations. The unique nature of HiLASE lasers requires new approach, which makes design of the distribution system a state-of-the-art challenge.

  9. Synthesis of Nano-Scale Fast Ion Conducting Cubic Li7La3Zr2O12

    DTIC Science & Technology

    2013-09-25

    offer the flexibility to make nano-dimensional particles with high sinterability nor the ability to coat/protect electrode powders. By developing a...sintering temperature are needed. One possible approach is to use small particles , such as nano-scale particles , that can be sintered at lower temperatures...matrix to suppress Li dendrite penetration. By developing a sol–gel process, the LLZO particle size can be precisely tuned, from the nanometer to the

  10. Minerva Detector Calibration

    NASA Astrophysics Data System (ADS)

    Rakotondravohitra, Laza

    2013-04-01

    Current and future neutrino oscillation experiments depend on precise knowledge of neutrino-nucleus cross-sections. Minerva is a neutrino scattering experiment at Fermilab. Minerva was designed to make precision measurements of low energy neutrino and antineutrino cross sections on a variety of different materials (plastic scintillator, C, Fe, Pb, He and H2O). In Order to make these measurements, it is crucial that the detector is carefully calibrated.This talk will describe how MINERvA uses muons from upstream neutrino interactions as a calibration source to convert electronics output to absolute energy deposition.

  11. Calibration of the Late Cretaceous to Paleocene geomagnetic polarity and astrochronological time scales: new results from high-precision U-Pb geochronology

    NASA Astrophysics Data System (ADS)

    Ramezani, Jahandar; Clyde, William; Wang, Tiantian; Johnson, Kirk; Bowring, Samuel

    2016-04-01

    Reversals in the Earth's magnetic polarity are geologically abrupt events of global magnitude that makes them ideal timelines for stratigraphic correlation across a variety of depositional environments, especially where diagnostic marine fossils are absent. Accurate and precise calibration of the Geomagnetic Polarity Timescale (GPTS) is thus essential to the reconstruction of Earth history and to resolving the mode and tempo of biotic and environmental change in deep time. The Late Cretaceous - Paleocene GPTS is of particular interest as it encompasses a critical period of Earth history marked by the Cretaceous greenhouse climate, the peak of dinosaur diversity, the end-Cretaceous mass extinction and its paleoecological aftermaths. Absolute calibration of the GPTS has been traditionally based on sea-floor spreading magnetic anomaly profiles combined with local magnetostratigraphic sequences for which a numerical age model could be established by interpolation between an often limited number of 40Ar/39Ar dates from intercalated volcanic ash deposits. Although the Neogene part of the GPTS has been adequately calibrated using cyclostratigraphy-based, astrochronological schemes, the application of these approaches to pre-Neogene parts of the timescale has been complicated given the uncertainties of the orbital models and the chaotic behavior of the solar system this far back in time. Here we present refined chronostratigraphic frameworks based on high-precision U-Pb geochronology of ash beds from the Western Interior Basin of North America and the Songliao Basin of Northeast China that places tight temporal constraints on the Late Cretaceous to Paleocene GPTS, either directly or by testing their astrochronological underpinnings. Further application of high-precision radioisotope geochronology and calibrated astrochronology promises a complete and robust Cretaceous-Paleogene GPTS, entirely independent of sea-floor magnetic anomaly profiles.

  12. The precise temporal calibration of dinosaur origins

    PubMed Central

    Marsicano, Claudia A.; Irmis, Randall B.; Mancuso, Adriana C.; Mundil, Roland; Chemale, Farid

    2016-01-01

    Dinosaurs have been major components of ecosystems for over 200 million years. Although different macroevolutionary scenarios exist to explain the Triassic origin and subsequent rise to dominance of dinosaurs and their closest relatives (dinosauromorphs), all lack critical support from a precise biostratigraphically independent temporal framework. The absence of robust geochronologic age control for comparing alternative scenarios makes it impossible to determine if observed faunal differences vary across time, space, or a combination of both. To better constrain the origin of dinosaurs, we produced radioisotopic ages for the Argentinian Chañares Formation, which preserves a quintessential assemblage of dinosaurian precursors (early dinosauromorphs) just before the first dinosaurs. Our new high-precision chemical abrasion thermal ionization mass spectrometry (CA-TIMS) U–Pb zircon ages reveal that the assemblage is early Carnian (early Late Triassic), 5- to 10-Ma younger than previously thought. Combined with other geochronologic data from the same basin, we constrain the rate of dinosaur origins, demonstrating their relatively rapid origin in a less than 5-Ma interval, thus halving the temporal gap between assemblages containing only dinosaur precursors and those with early dinosaurs. After their origin, dinosaurs only gradually dominated mid- to high-latitude terrestrial ecosystems millions of years later, closer to the Triassic–Jurassic boundary. PMID:26644579

  13. Ultra-precision turning of complex spiral optical delay line

    NASA Astrophysics Data System (ADS)

    Zhang, Xiaodong; Li, Po; Fang, Fengzhou; Wang, Qichang

    2011-11-01

    Optical delay line (ODL) implements the vertical or depth scanning of optical coherence tomography, which is the most important factor affecting the scanning resolution and speed. The spinning spiral mirror is found as an excellent optical delay device because of the high-speed and high-repetition-rate. However, it is one difficult task to machine the mirror due to the special shape and precision requirement. In this paper, the spiral mirror with titled parabolic generatrix is proposed, and the ultra-precision turning method is studied for its machining using the spiral mathematic model. Another type of ODL with the segmental shape is also introduced and machined to make rotation balance for the mass equalization when scanning. The efficiency improvement is considered in details, including the rough cutting with the 5- axis milling machine, the machining coordinates unification, and the selection of layer direction in turning. The onmachine measuring method based on stylus gauge is designed to analyze the shape deviation. The air bearing is used as the measuring staff and the laser interferometer sensor as the position sensor, whose repeatability accuracy is proved up to 10nm and the stable feature keeps well. With this method developed, the complex mirror with nanometric finish of 10.7nm in Ra and the form error within 1um are achieved.

  14. Precise optical observation of 0.5-GPa shock waves in condensed materials

    NASA Astrophysics Data System (ADS)

    Nagayama, Kunihito; Mori, Yasuhito

    1999-06-01

    Precision optical observation method was developed to study impact-generated high-pressure shock waves in condensed materials. The present method makes it possible to sensitively detect the shock waves of the relatively low shock stress around 0.5 GPa. The principle of the present method is based on the use of total internal reflection by triangular prisms placed on the free surface of a target assembly. When a plane shock wave arrives at the free surface, the light reflected from the prisms extinguishes instantaneously. The reason is that the total internal reflection changes to the reflection depending on micron roughness of the free surface after the shock arrival. The shock arrival at the bottom face of the prisms can be detected here by two kinds of methods, i.e., a photographic method and a gauge method. The photographic method is an inclined prism method of using a high-speed streak camera. The shock velocity and the shock tilt angle can be estimated accurately from an obtained streak photograph. While in the gauge method, an in-material PVDF stress gauge is combined with an optical prism-pin. The PVDF gauge records electrically the stress profile behind the shockwave front, and the Hugoniot data can be precisely measured by combining the prism pin with the PVDF gauge.

  15. 70 Years of Making the World Safer

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    None

    This video shows our roles in making the world safer — working to end World War II, providing stable isotopes for research, providing unique precision manufacturing capabilities, and meeting nonproliferation and global security missions.

  16. High Performance Clocks and Gravity Field Determination

    NASA Astrophysics Data System (ADS)

    Müller, J.; Dirkx, D.; Kopeikin, S. M.; Lion, G.; Panet, I.; Petit, G.; Visser, P. N. A. M.

    2018-02-01

    Time measured by an ideal clock crucially depends on the gravitational potential and velocity of the clock according to general relativity. Technological advances in manufacturing high-precision atomic clocks have rapidly improved their accuracy and stability over the last decade that approached the level of 10^{-18}. This notable achievement along with the direct sensitivity of clocks to the strength of the gravitational field make them practically important for various geodetic applications that are addressed in the present paper. Based on a fully relativistic description of the background gravitational physics, we discuss the impact of those highly-precise clocks on the realization of reference frames and time scales used in geodesy. We discuss the current definitions of basic geodetic concepts and come to the conclusion that the advances in clocks and other metrological technologies will soon require the re-definition of time scales or, at least, clarification to ensure their continuity and consistent use in practice. The relative frequency shift between two clocks is directly related to the difference in the values of the gravity potential at the points of clock's localization. According to general relativity the relative accuracy of clocks in 10^{-18} is equivalent to measuring the gravitational red shift effect between two clocks with the height difference amounting to 1 cm. This makes the clocks an indispensable tool in high-precision geodesy in addition to laser ranging and space geodetic techniques. We show how clock measurements can provide geopotential numbers for the realization of gravity-field-related height systems and can resolve discrepancies in classically-determined height systems as well as between national height systems. Another application of clocks is the direct use of observed potential differences for the improved recovery of regional gravity field solutions. Finally, clock measurements for space-borne gravimetry are analyzed along with closely-related deficiencies of this method like an extra-ordinary knowledge of the spacecraft velocity, etc. For all these applications besides the near-future prospects, we also discuss the challenges that are related to using those novel clock data in geodesy.

  17. [Application Progress of Three-dimensional Laser Scanning Technology in Medical Surface Mapping].

    PubMed

    Zhang, Yonghong; Hou, He; Han, Yuchuan; Wang, Ning; Zhang, Ying; Zhu, Xianfeng; Wang, Mingshi

    2016-04-01

    The booming three-dimensional laser scanning technology can efficiently and effectively get spatial three-dimensional coordinates of the detected object surface and reconstruct the image at high speed,high precision and large capacity of information.Non-radiation,non-contact and the ability of visualization make it increasingly popular in three-dimensional surface medical mapping.This paper reviews the applications and developments of three-dimensional laser scanning technology in medical field,especially in stomatology,plastic surgery and orthopedics.Furthermore,the paper also discusses the application prospects in the future as well as the biomedical engineering problems it would encounter with.

  18. Signal processing system for electrotherapy applications

    NASA Astrophysics Data System (ADS)

    Płaza, Mirosław; Szcześniak, Zbigniew

    2017-08-01

    The system of signal processing for electrotherapeutic applications is proposed in the paper. The system makes it possible to model the curve of threshold human sensitivity to current (Dalziel's curve) in full medium frequency range (1kHz-100kHz). The tests based on the proposed solution were conducted and their results were compared with those obtained according to the assumptions of High Tone Power Therapy method and referred to optimum values. Proposed system has high dynamics and precision of mapping the curve of threshold human sensitivity to current and can be used in all methods where threshold curves are modelled.

  19. Field design factors affecting the precision of ryegrass forage yield estimation

    USDA-ARS?s Scientific Manuscript database

    Field-based agronomic and genetic research relies heavily on the data generated from field evaluations. Therefore, it is imperative to optimize the precision and accuracy of yield estimates in cultivar evaluation trials to make reliable selections. Experimental error in yield trials is sensitive to ...

  20. Isothermal Battery Calorimeters | Transportation Research | NREL

    Science.gov Websites

    only calorimeters in the world capable of providing the precise thermal measurements needed for safer battery energy efficiency with 98% accuracy and provide precise measurements through complete thermal make it possible for battery developers to predict thermal performance before installing batteries in

  1. Bringing Superconductor Digital Technology to the Market Place

    NASA Astrophysics Data System (ADS)

    Nisenoff, Martin

    The unique properties of superconductivity can be exploited to provide the ultimate in electronic technology for systems such as ultra-precise analogue-to-digital and digital-to-analogue converters, precise DC and AC voltage standards, ultra high speed logic circuits and systems (both digital and hybrid analogue-digital systems), and very high throughput network routers and supercomputers which would have superior electrical performance at lower overall electrical power consumption compared to systems with comparable performance which are fabricated using conventional room temperature technologies. This potential for high performance electronics with reduced power consumption would have a positive impact on slowing the increase in the demand for electrical utility power by the information technology community on the overall electrical power grid. However, before this technology can be successfully brought to the commercial market place, there must be an aggressive investment of resources and funding to develop the required infrastructure needed to yield these high performance superconductor systems, which will be reliable and available at low cost. The author proposes that it will require a concerted effort by the superconductor and cryogenic communities to bring this technology to the commercial market place or make it available for widespread use in scientific instrumentation.

  2. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Not Available

    The GEM collaboration was formed in June 1991 to develop a major detector for the SSC. The primary physics objectives of GEM are those central to the motivation for the SSC, to study high p{sub T} physics - exemplified by the search for Higgs bosons - and to search for new physics beyond the standard model. The authors present in this Technical Design Report (TDR) a detector with broad capabilities for the discovery and subsequent study of electroweak symmetry breaking, the origin of mass and flavor, and other physics requiring precise measurements of gammas, electrons, and muons - hence themore » name, GEM. In addition, as a design goal, they have taken care to provide the robustness needed to do the physics that requires high luminosity. Finally, good coverage and hermeticity allow the detection of missing transverse energy, E{sub T}. The GEM design emphasizes clean identification and high resolution measurement of the primary physics signatures for high p{sub T} physics. The approach is to make precise energy measurements that maximize the sensitivity to rare narrow resonances, to detect the elementary interaction products (quarks, leptons, and photons), and to build in the features required to reduce backgrounds.« less

  3. High-Precision Measurement of 13C/12C Isotopic Ratio Using Gas Chromatography-Combustion-Cavity Ring-Down Spectroscopy

    NASA Astrophysics Data System (ADS)

    Saad, N.; Kuramoto, D. S.; Haase, C.; Crosson, E.; Tan, S.; Zare, R. N.

    2009-12-01

    Light stable isotope analysis, and in particular, compound specific isotopic analysis (CSIA), is a valuable tool to elucidate pathways and provide a better insight into biological, ecological, and geological systems. We present here the results of compound-specific isotopic carbon analysis of short chain hydrocarbons using the world’s first combination of gas chromatography, combustion interface, and cavity ring-down spectroscopy (GC-C-CRDS). Cavity ring-down spectroscopy (CRDS) is a highly sensitive optical spectroscopy, one application of which is to measure the stable isotopic ratios in small molecules. Because it uses a highly reflective optical cavity with many kilometers effective path length, CRDS provides some of the most sensitive and precise optical absorption measurements. Most optical spectroscopy isotopic analysis measures the quantities of each isotopologue independently using their distinct ro-vibrational spectra. The most common isotopes measured with optical spectroscopy are 13C and 12C in carbon dioxide. However, the isotopes of hydrogen, oxygen, and sulfur have also been measured. Unlike isotope ratio mass spectrometry (IRMS), optical spectroscopy can distinguish among isobars, which have essentially identical m/z ratios. The combination of chemical separation, chemical conversion, and CRDS makes a nearly universal tool for isotopic analysis of mixtures. In addition, CRDS can tolerate a variety of compounds mixed with the target. For example, CRDS can measure carbon dioxide and its isotopic 13C/12C ratio in the presence of oxygen. Using the novel GC-C-CRDS system, we injected a 75-microliter mixture of approximately equal quantities of methane, ethane, and propane into a gas chromatograph using helium as carrier gas. The methane, ethane, and propane were separated in time by 100 to 200 seconds after the chromatograph. Oxygen gas was added, and the hydrocarbons were combusted in a catalytic combustor with platinum and nickel, held at 1150oC. The combusted products were combined with dry nitrogen gas to provide sufficient gas flow for the CRDS analyzer, which measured the 13C/12C isotopic ratio of the separated methane, ethane, and propane, obtaining a precision of 0.95 permil or better. The calibration accuracy was within 3 permil of the values determined using IRMS. The current CRDS-based system is less expensive, does not require highly trained personnel to operate, and is portable, compared with IRMS. We anticipate that advances in spectroscopic analysis will improve the precision and accuracy of the CRDS isotopic measurement, making it comparable with IRMS.

  4. Potential for long-term, high-frequency, high-precision methane isotope measurements to improve UK emissions estimates

    NASA Astrophysics Data System (ADS)

    Rennick, Chris; Bausi, Francesco; Arnold, Tim

    2017-04-01

    On the global scale methane (CH4) concentrations have more than doubled over the last 150 years, and the contribution to the enhanced greenhouse effect is almost half of that due to the increase in carbon dioxide (CO2) over the same period. Microbial, fossil fuel, biomass burning and landfill are dominant methane sources with differing annual variabilities; however, in the UK for example, mixing ratio measurements from a tall tower network and regional scale inversion modelling have thus far been unable to disaggregate emissions from specific source categories with any significant certainty. Measurement of the methane isotopologue ratios will provide the additional information needed for more robust sector attribution, which will be important for directing policy action Here we explore the potential for isotope ratio measurements to improve the interpretation of atmospheric mixing ratios beyond calculation of total UK emissions, and describe current analytical work at the National Physical Laboratory that will realise deployment of such measurements. We simulate isotopic variations at the four UK greenhouse gas tall tower network sites to understand where deployment of the first isotope analyser would be best situated. We calculate the levels of precision needed in both δ-13C and δ-D in order to detect particular scenarios of emissions. Spectroscopic measurement in the infrared by quantum cascade laser (QCL) absorption is a well-established technique to quantify the mixing ratios of trace species in atmospheric samples and, as has been demonstrated in 2016, if coupled to a suitable preconcentrator then high-precision measurements are possible. The current preconcentration system under development at NPL is designed to make the highest precision measurements yet of the standard isotope ratios via a new large-volume cryogenic trap design and controlled thermal desorption into a QCL spectrometer. Finally we explore the potential for the measurement of clumped isotopes at high frequency and precision. The doubly-substituted 13CH3D isotopologue is a tracer for methane formed at geological temperatures, and will provide additional information for identification of these sources.

  5. Making Laser Beams Visible.

    ERIC Educational Resources Information Center

    Knotts, Michael

    1993-01-01

    Describes an inexpensive fog machine that is useful for photography and laser demonstrations. The apparatus uses liquid nitrogen to chill steam to make a fine mist safe for precision optics. The device can be made for around $50. (MVL)

  6. Identification of ground motion features for high-tech facility under far field seismic waves using wavelet packet transform

    NASA Astrophysics Data System (ADS)

    Huang, Shieh-Kung; Loh, Chin-Hsiung; Chen, Chin-Tsun

    2016-04-01

    Seismic records collected from earthquake with large magnitude and far distance may contain long period seismic waves which have small amplitude but with dominant period up to 10 sec. For a general situation, the long period seismic waves will not endanger the safety of the structural system or cause any uncomfortable for human activity. On the contrary, for those far distant earthquakes, this type of seismic waves may cause a glitch or, furthermore, breakdown to some important equipments/facilities (such as the high-precision facilities in high-tech Fab) and eventually damage the interests of company if the amplitude becomes significant. The previous study showed that the ground motion features such as time-variant dominant frequencies extracted using moving window singular spectrum analysis (MWSSA) and amplitude characteristics of long-period waves identified from slope change of ground motion Arias Intensity can efficiently indicate the damage severity to the high-precision facilities. However, embedding a large hankel matrix to extract long period seismic waves make the MWSSA become a time-consumed process. In this study, the seismic ground motion data collected from broadband seismometer network located in Taiwan were used (with epicenter distance over 1000 km). To monitor the significant long-period waves, the low frequency components of these seismic ground motion data are extracted using wavelet packet transform (WPT) to obtain wavelet coefficients and the wavelet entropy of coefficients are used to identify the amplitude characteristics of long-period waves. The proposed method is a timesaving process compared to MWSSA and can be easily implemented for real-time detection. Comparison and discussion on this method among these different seismic events and the damage severity to the high-precision facilities in high-tech Fab is made.

  7. Precision engineering: an evolutionary perspective.

    PubMed

    Evans, Chris J

    2012-08-28

    Precision engineering is a relatively new name for a technology with roots going back over a thousand years; those roots span astronomy, metrology, fundamental standards, manufacturing and money-making (literally). Throughout that history, precision engineers have created links across disparate disciplines to generate innovative responses to society's needs and wants. This review combines historical and technological perspectives to illuminate precision engineering's current character and directions. It first provides us a working definition of precision engineering and then reviews the subject's roots. Examples will be given showing the contributions of the technology to society, while simultaneously showing the creative tension between the technological convergence that spurs new directions and the vertical disintegration that optimizes manufacturing economics.

  8. Template-assisted fabrication of protein nanocapsules

    NASA Astrophysics Data System (ADS)

    Dougherty, Shelley A.; Liang, Jianyu; Kowalik, Timothy F.

    2009-02-01

    Bionanomaterials have recently begun to spark a great amount of interest and could potentially revolutionize biomedical research. Nanoparticles, nanocapsules, and nanotubular structures are becoming attractive options in drug and gene delivery. The size of the delivery vehicles greatly impacts cellular uptake and makes it highly desirable to precisely control the diameter and length of nanocarriers to make uniform nanoparticles at low cost. Carbon nanotubes have shown great potential within the field of drug and gene delivery. However, their insolubility and cytotoxicity could severely delay FDA approval. A desirable alternative would be to fabricate nanostructures from biomaterials such as proteins, peptides, or liposomes, which are already FDA approved. In this article we demonstrate the preparation of protein nanocapsules with both ends sealed using a template-assisted alternate immersion method combined with controlled cleaving. Glucose oxidase nanocapsules with controllable diameter, wall thickness, and length were fabricated and characterized with SEM and TEM. The biochemical activity of glucose oxidase in the form of nanocapsules after processing was confirmed using UV spectrometry. Our future work will explore proteins suitable for drug encapsulation and cellular uptake and will focus on optimizing the cleaving process to gain precise control over the length of the nanocapsules.

  9. Precision half-life measurement of 11C: The most precise mirror transition F t value

    NASA Astrophysics Data System (ADS)

    Valverde, A. A.; Brodeur, M.; Ahn, T.; Allen, J.; Bardayan, D. W.; Becchetti, F. D.; Blankstein, D.; Brown, G.; Burdette, D. P.; Frentz, B.; Gilardy, G.; Hall, M. R.; King, S.; Kolata, J. J.; Long, J.; Macon, K. T.; Nelson, A.; O'Malley, P. D.; Skulski, M.; Strauss, S. Y.; Vande Kolk, B.

    2018-03-01

    Background: The precise determination of the F t value in T =1 /2 mixed mirror decays is an important avenue for testing the standard model of the electroweak interaction through the determination of Vu d in nuclear β decays. 11C is an interesting case, as its low mass and small QE C value make it particularly sensitive to violations of the conserved vector current hypothesis. The present dominant source of uncertainty in the 11CF t value is the half-life. Purpose: A high-precision measurement of the 11C half-life was performed, and a new world average half-life was calculated. Method: 11C was created by transfer reactions and separated using the TwinSol facility at the Nuclear Science Laboratory at the University of Notre Dame. It was then implanted into a tantalum foil, and β counting was used to determine the half-life. Results: The new half-life, t1 /2=1220.27 (26 ) s, is consistent with the previous values but significantly more precise. A new world average was calculated, t1/2 world=1220.41 (32 ) s, and a new estimate for the Gamow-Teller to Fermi mixing ratio ρ is presented along with standard model correlation parameters. Conclusions: The new 11C world average half-life allows the calculation of a F tmirror value that is now the most precise value for all superallowed mixed mirror transitions. This gives a strong impetus for an experimental determination of ρ , to allow for the determination of Vu d from this decay.

  10. Joint denoising and distortion correction of atomic scale scanning transmission electron microscopy images

    NASA Astrophysics Data System (ADS)

    Berkels, Benjamin; Wirth, Benedikt

    2017-09-01

    Nowadays, modern electron microscopes deliver images at atomic scale. The precise atomic structure encodes information about material properties. Thus, an important ingredient in the image analysis is to locate the centers of the atoms shown in micrographs as precisely as possible. Here, we consider scanning transmission electron microscopy (STEM), which acquires data in a rastering pattern, pixel by pixel. Due to this rastering combined with the magnification to atomic scale, movements of the specimen even at the nanometer scale lead to random image distortions that make precise atom localization difficult. Given a series of STEM images, we derive a Bayesian method that jointly estimates the distortion in each image and reconstructs the underlying atomic grid of the material by fitting the atom bumps with suitable bump functions. The resulting highly non-convex minimization problems are solved numerically with a trust region approach. Existence of minimizers and the model behavior for faster and faster rastering are investigated using variational techniques. The performance of the method is finally evaluated on both synthetic and real experimental data.

  11. High-precision temperature control and stabilization using a cryocooler.

    PubMed

    Hasegawa, Yasuhiro; Nakamura, Daiki; Murata, Masayuki; Yamamoto, Hiroya; Komine, Takashi

    2010-09-01

    We describe a method for precisely controlling temperature using a Gifford-McMahon (GM) cryocooler that involves inserting fiber-reinforced-plastic dampers into a conventional cryosystem. Temperature fluctuations in a GM cryocooler without a large heat bath or a stainless-steel damper at 4.2 K are typically of the order of 200 mK. It is particularly difficult to control the temperature of a GM cryocooler at low temperatures. The fiber-reinforced-plastic dampers enabled us to dramatically reduce temperature fluctuations at low temperatures. A standard deviation of the temperature fluctuations of 0.21 mK could be achieved when the temperature was controlled at 4.200 0 K using a feedback temperature control system with two heaters. Adding the dampers increased the minimum achievable temperature from 3.2 to 3.3 K. Precise temperature control between 4.200 0 and 300.000 K was attained using the GM cryocooler, and the standard deviation of the temperature fluctuations was less than 1.2 mK even at 300 K. This technique makes it possible to control and stabilize the temperature using a GM cryocooler.

  12. A T-Type Capacitive Sensor Capable of Measuring 5-DOF Error Motions of Precision Spindles

    PubMed Central

    Xiang, Kui; Qiu, Rongbo; Mei, Deqing; Chen, Zichen

    2017-01-01

    The precision spindle is a core component of high-precision machine tools, and the accurate measurement of its error motions is important for improving its rotation accuracy as well as the work performance of the machine. This paper presents a T-type capacitive sensor (T-type CS) with an integrated structure. The proposed sensor can measure the 5-degree-of-freedom (5-DOF) error motions of a spindle in-situ and simultaneously by integrating electrode groups in the cylindrical bore of the stator and the outer end face of its flange, respectively. Simulation analysis and experimental results show that the sensing electrode groups with differential measurement configuration have near-linear output for the different types of rotor displacements. What’s more, the additional capacitance generated by fringe effects has been reduced about 90% with the sensing electrode groups fabricated based on flexible printed circuit board (FPCB) and related processing technologies. The improved signal processing circuit has also been increased one times in the measuring performance and makes the measured differential output capacitance up to 93% of the theoretical values. PMID:28846631

  13. Exploiting position effects and the gypsy retrovirus insulator to engineer precisely expressed transgenes.

    PubMed

    Markstein, Michele; Pitsouli, Chrysoula; Villalta, Christians; Celniker, Susan E; Perrimon, Norbert

    2008-04-01

    A major obstacle to creating precisely expressed transgenes lies in the epigenetic effects of the host chromatin that surrounds them. Here we present a strategy to overcome this problem, employing a Gal4-inducible luciferase assay to systematically quantify position effects of host chromatin and the ability of insulators to counteract these effects at phiC31 integration loci randomly distributed throughout the Drosophila genome. We identify loci that can be exploited to deliver precise doses of transgene expression to specific tissues. Moreover, we uncover a previously unrecognized property of the gypsy retrovirus insulator to boost gene expression to levels severalfold greater than at most or possibly all un-insulated loci, in every tissue tested. These findings provide the first opportunity to create a battery of transgenes that can be reliably expressed at high levels in virtually any tissue by integration at a single locus, and conversely, to engineer a controlled phenotypic allelic series by exploiting several loci. The generality of our approach makes it adaptable to other model systems to identify and modify loci for optimal transgene expression.

  14. Carbon-14 wiggle-match dating of peat deposits: advantages and limitations

    NASA Astrophysics Data System (ADS)

    Blaauw, Maarten; van Geel, Bas; Mauquoy, Dmitri; van der Plicht, Johannes

    2004-02-01

    Carbon-14 wiggle-match dating (WMD) of peat deposits uses the non-linear relationship between 14C age and calendar age to match the shape of a series of closely spaced peat 14C dates with the 14C calibration curve. The method of WMD is discussed, and its advantages and limitations are compared with calibration of individual dates. A numerical approach to WMD is introduced that makes it possible to assess the precision of WMD chronologies. During several intervals of the Holocene, the 14C calibration curve shows less pronounced fluctuations. We assess whether wiggle-matching is also a feasible strategy for these parts of the 14C calibration curve. High-precision chronologies, such as obtainable with WMD, are needed for studies of rapid climate changes and their possible causes during the Holocene. Copyright

  15. A novel laser ranging system for measurement of ground-to-satellite distances

    NASA Technical Reports Server (NTRS)

    Golden, K. E.; Kind, D. E.; Leonard, S. L.; Ward, R. C.

    1973-01-01

    A technique was developed for improving the precision of laser ranging measurements of ground-to-satellite distances. The method employs a mode-locked laser transmitter and utilizes an image converter tube equipped with deflection plates in measuring the time of flight of the laser pulse to a distant retroreflector and back. Samples of the outgoing and returning light pulses are focussed on the photocathode of the image converter tube, whose deflection plates are driven by a high-voltage 120 MHz sine wave derived from a very stable oscillator. From the relative positions of the images produced at the output phosphor by the two light pulses, it is possible to make a precise determination of the fractional amount by which the time of flight exceeds some large integral multiple of the period of the deflection sinusoid.

  16. Lessons from the GP-B Experience for Future Fundamental Physics Missions in Space

    NASA Technical Reports Server (NTRS)

    Kolodziejczak, Jeffery

    2006-01-01

    Gravity Probe B launched in April 2004 and completed its science data collection in September 2005, with the objective of sub-milliarcsec measurement of two General Relativistic effects on the spin axis orientation of orbiting gyroscopes. Much of the technology required by GP-B has potential application in future missions intended to make precision measurements. The philosophical approach and experiment design principles developed for GP-B are equally adaptable to these mission concepts. This talk will discuss GP-B's experimental approach and the technological and philosophical lessons learned that apply to future experiments in fundamental physics. Measurement of fundamental constants to high precision, probes of short-range forces, searches for equivalence principle violations, and detection of gravitational waves are examples of concepts and missions that will benefit kern GP-B's experience.

  17. Note: Compact and light displacement sensor for a precision measurement system in large motion

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Lee, Sang Heon, E-mail: shlee@andong.ac.kr

    We developed a compact and light displacement sensor applicable to systems that require wide range motions of its sensing device. The proposed sensor utilized the optical pickup unit of the optical disk drive, which has been used applied to atomic force microscopy (AFM) because of its compactness and lightness as well as its high performance. We modified the structure of optical pickup unit and made the compact sensor driver attachable to a probe head of AFM to make large rotation. The feasibilities of the developed sensor for a general probe-moving measurement device and for probe-rotating AFM were verified. Moreover, amore » simple and precise measurement of alignment between centers of rotator and probe tip in probe-rotation AFM was experimentally demonstrated using the developed sensor.« less

  18. The white dwarf mass-radius relation with Gaia, Hubble and FUSE

    NASA Astrophysics Data System (ADS)

    Joyce, Simon R. G.; Barstow, Martin A.; Casewell, Sarah L.; Holberg, Jay B.; Bond, Howard E.

    2018-04-01

    White dwarfs are becoming useful tools for many areas of astronomy. They can be used as accurate chronometers over Gyr timescales. They are also clues to the history of star formation in our galaxy. Many of these studies require accurate estimates of the mass of the white dwarf. The theoretical mass-radius relation is often invoked to provide these mass estimates. While the theoretical mass-radius relation is well developed, observational tests of this relation show a much larger scatter in the results than expected. High precision observational tests to confirm this relation are required. Gaia is providing distance measurements which will remove one of the main source of uncertainty affecting most previous observations. We combine Gaia distances with spectra from the Hubble and FUSE satelites to make precise tests of the white dwarf mass-radius relation.

  19. Development of a Hydrogen Møller Polarimeter for Precision Parity-Violating Electron Scattering

    NASA Astrophysics Data System (ADS)

    Gray, Valerie M.

    2013-10-01

    Parity-violating electron scattering experiments allow for testing the Standard Model at low energy accelerators. Future parity-violating electron scattering experiments, like the P2 experiment at the Johannes Gutenberg University, Mainz, Germany, and the MOLLER and SoLID experiments at Jefferson Lab will measure observables predicted by the Standard Model to high precision. In order to make these measurements, we will need to determine the polarization of the electron beam to sub-percent precision. The present way of measuring the polarization, with Møller scattering in iron foils or using Compton laser backscattering, will not easily be able to reach this precision. The novel Hydrogen Møller Polarimeter presents a non-invasive way to measure the electron polarization by scattering the electron beam off of atomic hydrogen gas polarized in a 7 Tesla solenoidal magnetic trap. This apparatus is expected to be operational by 2016 in Mainz. Currently, simulations of the polarimeter are used to develop the detection system at College of William & Mary, while the hydrogen trap and superconducting solenoid magnet are being developed at the Johannes Gutenberg University, Mainz. I will discuss the progress of the design and development of this novel polarimeter system. This material is based upon work supported by the National Science Foundation under Grant No. PHY-1206053.

  20. Robotic Surgery

    NASA Technical Reports Server (NTRS)

    2000-01-01

    The Automated Endoscopic System for Optimal Positioning, or AESOP, was developed by Computer Motion, Inc. under a SBIR contract from the Jet Propulsion Lab. AESOP is a robotic endoscopic positioning system used to control the motion of a camera during endoscopic surgery. The camera, which is mounted at the end of a robotic arm, previously had to be held in place by the surgical staff. With AESOP the robotic arm can make more precise and consistent movements. AESOP is also voice controlled by the surgeon. It is hoped that this technology can be used in space repair missions which require precision beyond human dexterity. A new generation of the same technology entitled the ZEUS Robotic Surgical System can make endoscopic procedures even more successful. ZEUS allows the surgeon control various instruments in its robotic arms, allowing for the precision the procedure requires.

  1. Profit through predictability: The MRF difference at optimax

    NASA Astrophysics Data System (ADS)

    Light, Brandon

    2007-05-01

    In the manufacturing business, there is one product that matters, money. Whether making shoelaces or aircraft carriers a business that doesn't also make a profit doesn't stay around long. Being able to predict operational expenses is critical to determining a product's sale price. Priced too high a product won't sell, too low profit goes away. In the business of precision optics manufacturing, predictability has been often impossible or had large error bars. Manufacturing unpredictability made setting price a challenge. What if predictability could improve by changing the polishing process? Would a predictable, deterministic process lead to profit? Optimax Systems has experienced exactly that. Incorporating Magnetorheological Finishing (MRF) into its finishing process, Optimax saw parts categorized financially as "high risk" become a routine product of higher quality, delivered on time and within budget. Using actual production figures, this presentation will show how much incorporating MRF reduced costs, improved output and increased quality all at the same time.

  2. Note: A rigid piezo motor with large output force and an effective method to reduce sliding friction force

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Guo, Ying; Lu, Qingyou, E-mail: qxl@ustc.edu.cn; Hefei National Laboratory for Physical Sciences at Microscale, University of Science and Technology of China, Hefei, Anhui 230026

    2014-05-15

    We present a completely practical TunaDrive piezo motor. It consists of a central piezo stack sandwiched by two arm piezo stacks and two leg piezo stacks, respectively, which is then sandwiched and spring-clamped by a pair of parallel polished sapphire rods. It works by alternatively fast expanding and contracting the arm/leg stacks while slowly expanding/contracting the central stack simultaneously. The key point is that sufficiently fast expanding and contracting a limb stack can make its two sliding friction forces well cancel, resulting in the total sliding friction force is <10% of the total static friction force, which can help increasemore » output force greatly. The piezo motor's high compactness, precision, and output force make it perfect in building a high-quality harsh-condition (vibration resistant) atomic resolution scanning probe microscope.« less

  3. Beryllium-aluminum alloys for investment castings

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Nachtrab, W.T.; Levoy, N.

    1997-05-01

    Beryllium-aluminum alloys containing greater than 60 wt % beryllium are very favorable materials for applications requiring light weight and high stiffness. However, when produced by traditional powder metallurgical methods, these alloys are expensive and have limited applications. To reduce the cost of making beryllium-aluminum components, Nuclear Metals Inc. (NMI) and Lockheed Martin Electronics and Missiles have recently developed a family of patented beryllium-aluminum alloys that can be investment cast. Designated Beralcast, the alloys can achieve substantial weight savings because of their high specific strength and stiffness. In some cases, weight has been reduced by up to 50% over aluminum investmentmore » casting. Beralcast is now being used to make thin wall precision investment castings for several advanced aerospace applications, such as the RAH-66 Comanche helicopter and F-22 jet fighter. This article discusses alloy compositions, properties, casting method, and the effects of cobalt additions on strength.« less

  4. Intensification of the impact of high-intensity focused ultrasound (HIFU) with special spatiotemporal modulation

    NASA Astrophysics Data System (ADS)

    Gusev, V. A.; Rudenko, O. V.

    2013-01-01

    The principle of forming a special form of powerful acoustic signals is proposed, which makes it possible to ensure precise spatiotemporal beam focusing. The introduction of a transverse-coordinate-dependent local wave frequency is suggested, due to which the equality of the formation lengths of a discontinuity for all rays is achieved. This thereby ensures an increase in nonlinear absorption; as a result, the temperature and radiation action of focused ultrasound on the medium increase.

  5. A parallel implementation of 3D Zernike moment analysis

    NASA Astrophysics Data System (ADS)

    Berjón, Daniel; Arnaldo, Sergio; Morán, Francisco

    2011-01-01

    Zernike polynomials are a well known set of functions that find many applications in image or pattern characterization because they allow to construct shape descriptors that are invariant against translations, rotations or scale changes. The concepts behind them can be extended to higher dimension spaces, making them also fit to describe volumetric data. They have been less used than their properties might suggest due to their high computational cost. We present a parallel implementation of 3D Zernike moments analysis, written in C with CUDA extensions, which makes it practical to employ Zernike descriptors in interactive applications, yielding a performance of several frames per second in voxel datasets about 2003 in size. In our contribution, we describe the challenges of implementing 3D Zernike analysis in a general-purpose GPU. These include how to deal with numerical inaccuracies, due to the high precision demands of the algorithm, or how to deal with the high volume of input data so that it does not become a bottleneck for the system.

  6. The high cost of accurate knowledge.

    PubMed

    Sutcliffe, Kathleen M; Weber, Klaus

    2003-05-01

    Many business thinkers believe it's the role of senior managers to scan the external environment to monitor contingencies and constraints, and to use that precise knowledge to modify the company's strategy and design. As these thinkers see it, managers need accurate and abundant information to carry out that role. According to that logic, it makes sense to invest heavily in systems for collecting and organizing competitive information. Another school of pundits contends that, since today's complex information often isn't precise anyway, it's not worth going overboard with such investments. In other words, it's not the accuracy and abundance of information that should matter most to top executives--rather, it's how that information is interpreted. After all, the role of senior managers isn't just to make decisions; it's to set direction and motivate others in the face of ambiguities and conflicting demands. Top executives must interpret information and communicate those interpretations--they must manage meaning more than they must manage information. So which of these competing views is the right one? Research conducted by academics Sutcliffe and Weber found that how accurate senior executives are about their competitive environments is indeed less important for strategy and corresponding organizational changes than the way in which they interpret information about their environments. Investments in shaping those interpretations, therefore, may create a more durable competitive advantage than investments in obtaining and organizing more information. And what kinds of interpretations are most closely linked with high performance? Their research suggests that high performers respond positively to opportunities, yet they aren't overconfident in their abilities to take advantage of those opportunities.

  7. Mission Report on the Orbiter Camera Payload System (OCPS) Large Format Camera (LFC) and Attitude Reference System (ARS)

    NASA Technical Reports Server (NTRS)

    Mollberg, Bernard H.; Schardt, Bruton B.

    1988-01-01

    The Orbiter Camera Payload System (OCPS) is an integrated photographic system which is carried into earth orbit as a payload in the Space Transportation System (STS) Orbiter vehicle's cargo bay. The major component of the OCPS is a Large Format Camera (LFC), a precision wide-angle cartographic instrument that is capable of producing high resolution stereo photography of great geometric fidelity in multiple base-to-height (B/H) ratios. A secondary, supporting system to the LFC is the Attitude Reference System (ARS), which is a dual lens Stellar Camera Array (SCA) and camera support structure. The SCA is a 70-mm film system which is rigidly mounted to the LFC lens support structure and which, through the simultaneous acquisition of two star fields with each earth-viewing LFC frame, makes it possible to determine precisely the pointing of the LFC optical axis with reference to the earth nadir point. Other components complete the current OCPS configuration as a high precision cartographic data acquisition system. The primary design objective for the OCPS was to maximize system performance characteristics while maintaining a high level of reliability compatible with Shuttle launch conditions and the on-orbit environment. The full-up OCPS configuration was launched on a highly successful maiden voyage aboard the STS Orbiter vehicle Challenger on October 5, 1984, as a major payload aboard mission STS 41-G. This report documents the system design, the ground testing, the flight configuration, and an analysis of the results obtained during the Challenger mission STS 41-G.

  8. An Ultra-Precise Method for the Nano Thin-Film Removal

    NASA Astrophysics Data System (ADS)

    Pa, P. S.

    In this research an electrode-set is used to investigate via an ultra-precise method for the removal of Indium Tin Oxide (ITO) thin-film microstructure from defective display panels to conquer the low yield rate in display panel production as to from imperfect Indium Tin Oxide layer deposition is well known. This process, which involves the removal of ITO layer substructure by means of an electrochemical removal (ECMR), is of major interest to the optoelectronics semiconductor industry. In this electro machining process a high current flow and high feed rate of the display (color filter) achieves complete and efficient removal of the ITO layer. The ITO thin-film can be removed completely by a proper combination of feed rate and electric power. A small gap between the diameter cathode virtual rotation circle and the diameter virtual rotation circle also corresponds to a higher removal rate. A small anode edge radius with a small cathode edge radius effectively improves dregs discharge and is an advantage when associated with a high workpiece feed rate. This precision method for the recycling of defective display screen color filters is presented as an effective tool for use in the screen manufacturing process. The defective Indium Tin Oxide thin-film can be removed easily and cleanly in a short time. The complete removal of the ITO layer makes it possible to put these panels back into the production line for reuse with a considerable reduction of both waste and production cost.

  9. Antihydrogen Beams

    NASA Astrophysics Data System (ADS)

    Yamazaki, Yasunori; Doser, Michael; Pérez, Patrice

    2018-03-01

    Why does our universe consist purely of matter, even though the same amount of antimatter and matter should have been produced at the moment of the Big Bang 13.8 billion years ago? One of the most potentially fruitful approaches to address the mystery is to study the properties of antihydrogen and antiprotons. Because they are both stable, we can in principle make measurement precision as high as we need to see differences between these antimatter systems and their matter counterparts, i.e. hydrogen and protons. This is the goal of cold antihydrogen research. To study a fundamental symmetry-charge, parity, and time reversal (CPT) symmetry-which should lead to identical spectra in hydrogen and antihydrogen, as well as the weak equivalence principle (WEP), cold antihydrogen research seeks any discrepancies between matter and antimatter, which might also offer clues to the missing antimatter mystery. Precision tests of CPT have already been carried out in other systems, but antihydrogen spectroscopy offers the hope of reaching even higher sensitivity to violations of CPT. Meanwhile, utilizing the Earth and antihydrogen atoms as an experimental system, the WEP predicts a gravitational interaction between matter and antimatter that is identical to that between any two matter objects. The WEP has been tested to very high precision for a range of material compositions, but no such precision test using antimatter has yet been carried out, offering hope of a telltale inconsistency between matter and antimatter. In this Discovery book, we invite you to visit the frontiers of cold antimatter research, focusing on new technologies to form beams of antihydrogen atoms and antihydrogen ions, and new ways of interrogating the properties of antimatter.

  10. Surrogate biochemical markers: precise measurement for strategic drug and biologics development.

    PubMed

    Lee, J W; Hulse, J D; Colburn, W A

    1995-05-01

    More efficient drug and biologics development is necessary for future success of pharmaceutical and biotechnology companies. One way to achieve this objective is to use rationally selected surrogate markers to improve the early decision-making process. Using typical clinical chemistry methods to measure biochemical markers may not ensure adequate precision and reproducibility. In contrast, using analytical methods that meet good laboratory practices along with rational selection and validation of biochemical markers can give those who use them a competitive advantage over those who do not by providing meaningful data for earlier decision making.

  11. Alternative Films for Making Presentation Slides for the Occasional User.

    ERIC Educational Resources Information Center

    Hunt, Harold R., Jr.

    1985-01-01

    As alternatives to the well-known Kodak Kodalith film for making presentation slides, suggests using Kodak Technical Pan Film, 2415 and Kodak Precision Fine Film LPD4. Although less known, both films are capable of making excellent quality slides with minimum effort and, for the occasional user, offer advantages over the Kodalith-Diazochrome…

  12. Turbulence measurements in high Reynolds number boundary layers

    NASA Astrophysics Data System (ADS)

    Vallikivi, Margit; Smits, Alexander

    2013-11-01

    Measurements are conducted in zero pressure gradient turbulent boundary layers for Reynolds numbers from Reθ = 9,000 to 225,000. The experiments were performed in the High Reynolds number Test Facility (HRTF) at Princeton University, which uses compressed air as the working fluid. Nano-Scale Thermal Anemometry Probes (NSTAPs) are used to acquire data with very high spatial and temporal precision. These new data are used to study the scaling behavior of the streamwise velocity fluctuations in the boundary layer and make comparisons with the scaling of other wall-bounded turbulent flows. Supported under ONR Grant N00014-09-1-0263 (program manager Ron Joslin) and NSF Grant CBET-1064257 (program manager Henning Winter).

  13. The INTEGRAL scatterometer SPI

    NASA Technical Reports Server (NTRS)

    Mandrou, P.; Vedrenne, G.; Jean, P.; Kandel, B.; vonBallmoos, P.; Albernhe, F.; Lichti, G.; Schoenfelder, V.; Diehl, R.; Georgii, R.; hide

    1997-01-01

    The INTErnational Gamma Ray Astrophysics Laboratory (INTEGRAL) mission's onboard spectrometer, the INTEGRAL spectrometer (SPI), is described. The SPI constitutes one of the four main mission instruments. It is optimized for detailed measurements of gamma ray lines and for the mapping of diffuse sources. It combines a coded aperture mask with an array of large volume, high purity germanium detectors. The detectors make precise measurements of the gamma ray energies over the 20 keV to 8 MeV range. The instrument's characteristics are described and the Monte Carlo simulation of its performance is outlined. It will be possible to study gamma ray emission from compact objects or line profiles with a high energy resolution and a high angular resolution.

  14. a Band Selection Method for High Precision Registration of Hyperspectral Image

    NASA Astrophysics Data System (ADS)

    Yang, H.; Li, X.

    2018-04-01

    During the registration of hyperspectral images and high spatial resolution images, too much bands in a hyperspectral image make it difficult to select bands with good registration performance. Terrible bands are possible to reduce matching speed and accuracy. To solve this problem, an algorithm based on Cram'er-Rao lower bound theory is proposed to select good matching bands in this paper. The algorithm applies the Cram'er-Rao lower bound theory to the study of registration accuracy, and selects good matching bands by CRLB parameters. Experiments show that the algorithm in this paper can choose good matching bands and provide better data for the registration of hyperspectral image and high spatial resolution image.

  15. Detecting Patchy Reionization in the Cosmic Microwave Background.

    PubMed

    Smith, Kendrick M; Ferraro, Simone

    2017-07-14

    Upcoming cosmic microwave background (CMB) experiments will measure temperature fluctuations on small angular scales with unprecedented precision. Small-scale CMB fluctuations are a mixture of late-time effects: gravitational lensing, Doppler shifting of CMB photons by moving electrons [the kinematic Sunyaev-Zel'dovich (KSZ) effect], and residual foregrounds. We propose a new statistic which separates the KSZ signal from the others, and also allows the KSZ signal to be decomposed in redshift bins. The decomposition extends to high redshift and does not require external data sets such as galaxy surveys. In particular, the high-redshift signal from patchy reionization can be cleanly isolated, enabling future CMB experiments to make high-significance and qualitatively new measurements of the reionization era.

  16. Making and Measuring a Model of a Salt Marsh

    ERIC Educational Resources Information Center

    Fogleman, Tara; Curran, Mary Carla

    2007-01-01

    Students are often confused by the difference between the terms "accuracy" and "precision." In the following activities, students explore the definitions of accuracy and precision while learning about salt march ecology and the methods used by scientists to assess salt marsh health. The activities also address the concept that the ocean supports a…

  17. Innovative Way to Test Batteries Fills a Market Niche | News | NREL

    Science.gov Websites

    researchers, performs precise thermal measurements needed to design safer, longer-lasting, and more cost NREL researchers, are capable of performing the precise thermal measurements needed to make safer . Batteries cannot survive heat, and they need thermal management; IBCs are essential in measuring how much

  18. Thermodynamic property determination in low gravity

    NASA Technical Reports Server (NTRS)

    Margrave, J. L.

    1977-01-01

    Techniques for determining heat capacities and other properties of molten metals were investigated and critically evaluated. Precisely determining heat capacities calorimetrically in space poses several problems. The weight of a drop calorimeter block along with the necessity of obtaining a large number of data points tend to make traditional approaches appear infeasible. However, for many substances exhibiting sufficiently high thermal conductivities and with known emissivities, it appears possible to investigate their properties by observing the rate of cooling of a levitated sphere which is initially at a uniform temperature above the melting point. A special advantage of the levitation method is that considerable supercooling is expected, making the study of the heat capacities of molten metals both above and below their melting points possible.

  19. SCIAMACHY and FTS CO2 Retrievals Using the OCO Retrieval Algorithm

    NASA Technical Reports Server (NTRS)

    Boesch, Hartmut; Buchwitz, M.; Sen, Bhaswar; Toon, Geoffrey C.; Washenfelder, Rebecca A.; Wennberg, Paul O.

    2005-01-01

    The Orbiting Carbon Observatory (OCO) mission will make the first global, space-based measurements of atmospheric C02 with the precision and coverage needed to characterize C02 sources and sinks on regional scales. OCO will make spectrally and spatially highly resolved measurements of reflected sunlight in the 02A -band and two near-infrared C02 bands. To test the OCO retrieval algorithm, SCIAMACHY and ground-based Fourier Transform Spectrometer (FTS) measurements at Park Falls, Wisconsin have been analyzed. Good agreement between SCIAMACHY and FTS C02 columns has been found with SCIAMACHY showing a much larger scatter than FTS measurements. Both SCIAMACHY and FTS overestimate the surface pressure by a few percent which significantly impacts retrieved C02 columns.

  20. Copper Disk Manufactured at the Space Optics Manufacturing and Technology Center

    NASA Technical Reports Server (NTRS)

    1997-01-01

    This king-size copper disk, manufactured at the Space Optics Manufacturing and Technology Center (SOMTC) at the Marshall Space Flight Center (MSFC), is a special mold for making high resolution monitor screens. This master mold will be used to make several other molds, each capable of forming hundreds of screens that have a type of lens called a Fresnel lens. Weighing much less than conventional optics, Fresnel lenses have multiple concentric grooves, each formed to a precise angle, that together create the curvature needed to focus and project images. MSFC leads NASA's space optics manufacturing technology development as a technology leader for diamond turning. The machine used to manufacture this mold is among many one-of-a-kind pieces of equipment of MSFC's SOMTC.

  1. Generalised optical differentiation wavefront sensor: a sensitive high dynamic range wavefront sensor.

    PubMed

    Haffert, S Y

    2016-08-22

    Current wavefront sensors for high resolution imaging have either a large dynamic range or a high sensitivity. A new kind of wavefront sensor is developed which can have both: the Generalised Optical Differentiation wavefront sensor. This new wavefront sensor is based on the principles of optical differentiation by amplitude filters. We have extended the theory behind linear optical differentiation and generalised it to nonlinear filters. We used numerical simulations and laboratory experiments to investigate the properties of the generalised wavefront sensor. With this we created a new filter that can decouple the dynamic range from the sensitivity. These properties make it suitable for adaptive optic systems where a large range of phase aberrations have to be measured with high precision.

  2. 70 Years of Making the World Safer: Extended

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    None

    Extended version with narration. This video shows our roles in making the world safer — working to end World War II, providing stable isotopes for research, providing unique precision manufacturing capabilities, and meeting nonproliferation and global security missions.

  3. Integration of a synthetic vision system with airborne laser range scanner-based terrain referenced navigation for precision approach guidance

    NASA Astrophysics Data System (ADS)

    Uijt de Haag, Maarten; Campbell, Jacob; van Graas, Frank

    2005-05-01

    Synthetic Vision Systems (SVS) provide pilots with a virtual visual depiction of the external environment. When using SVS for aircraft precision approach guidance systems accurate positioning relative to the runway with a high level of integrity is required. Precision approach guidance systems in use today require ground-based electronic navigation components with at least one installation at each airport, and in many cases multiple installations to service approaches to all qualifying runways. A terrain-referenced approach guidance system is envisioned to provide precision guidance to an aircraft without the use of ground-based electronic navigation components installed at the airport. This autonomy makes it a good candidate for integration with an SVS. At the Ohio University Avionics Engineering Center (AEC), work has been underway in the development of such a terrain referenced navigation system. When used in conjunction with an Inertial Measurement Unit (IMU) and a high accuracy/resolution terrain database, this terrain referenced navigation system can provide navigation and guidance information to the pilot on a SVS or conventional instruments. The terrain referenced navigation system, under development at AEC, operates on similar principles as other terrain navigation systems: a ground sensing sensor (in this case an airborne laser scanner) gathers range measurements to the terrain; this data is then matched in some fashion with an onboard terrain database to find the most likely position solution and used to update an inertial sensor-based navigator. AEC's system design differs from today's common terrain navigators in its use of a high resolution terrain database (~1 meter post spacing) in conjunction with an airborne laser scanner which is capable of providing tens of thousands independent terrain elevation measurements per second with centimeter-level accuracies. When combined with data from an inertial navigator the high resolution terrain database and laser scanner system is capable of providing near meter-level horizontal and vertical position estimates. Furthermore, the system under development capitalizes on 1) The position and integrity benefits provided by the Wide Area Augmentation System (WAAS) to reduce the initial search space size and; 2) The availability of high accuracy/resolution databases. This paper presents results from flight tests where the terrain reference navigator is used to provide guidance cues for a precision approach.

  4. An efficient mixed-precision, hybrid CPU-GPU implementation of a nonlinearly implicit one-dimensional particle-in-cell algorithm

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Chen, Guangye; Chacon, Luis; Barnes, Daniel C

    2012-01-01

    Recently, a fully implicit, energy- and charge-conserving particle-in-cell method has been developed for multi-scale, full-f kinetic simulations [G. Chen, et al., J. Comput. Phys. 230, 18 (2011)]. The method employs a Jacobian-free Newton-Krylov (JFNK) solver and is capable of using very large timesteps without loss of numerical stability or accuracy. A fundamental feature of the method is the segregation of particle orbit integrations from the field solver, while remaining fully self-consistent. This provides great flexibility, and dramatically improves the solver efficiency by reducing the degrees of freedom of the associated nonlinear system. However, it requires a particle push per nonlinearmore » residual evaluation, which makes the particle push the most time-consuming operation in the algorithm. This paper describes a very efficient mixed-precision, hybrid CPU-GPU implementation of the implicit PIC algorithm. The JFNK solver is kept on the CPU (in double precision), while the inherent data parallelism of the particle mover is exploited by implementing it in single-precision on a graphics processing unit (GPU) using CUDA. Performance-oriented optimizations, with the aid of an analytical performance model, the roofline model, are employed. Despite being highly dynamic, the adaptive, charge-conserving particle mover algorithm achieves up to 300 400 GOp/s (including single-precision floating-point, integer, and logic operations) on a Nvidia GeForce GTX580, corresponding to 20 25% absolute GPU efficiency (against the peak theoretical performance) and 50-70% intrinsic efficiency (against the algorithm s maximum operational throughput, which neglects all latencies). This is about 200-300 times faster than an equivalent serial CPU implementation. When the single-precision GPU particle mover is combined with a double-precision CPU JFNK field solver, overall performance gains 100 vs. the double-precision CPU-only serial version are obtained, with no apparent loss of robustness or accuracy when applied to a challenging long-time scale ion acoustic wave simulation.« less

  5. Study of application and key technology of the high-energy laser weapon in optoelectronic countermeasure

    NASA Astrophysics Data System (ADS)

    Qu, Zhou; Xing, Hao; Wang, Dawei; Wang, Qiugui

    2015-10-01

    High-energy Laser weapon is a new-style which is developing rapidly nowadays. It is a one kind of direction energy weapon which can destroy the targets or make them invalid. High-energy Laser weapon has many merits such as concentrated energy, fast transmission, long operating range, satisfied precision, fast shift fire, anti-electromagnetic interference, reusability, cost-effectiveness. High-energy Laser weapon has huge potential for modern warfare since its laser beam launch attack to the target by the speed of light. High-energy Laser weapon can be deployed by multiple methods such as skyborne, carrier borne, vehicle-mounted, foundation, space platform. Besides the connection with command and control system, High-energy Laser weapon is consist of high-energy laser and beam steering. Beam steering is comprised of Large diameter launch system and Precision targeting systems. Meanwhile, beam steering includes the distance measurement of target location, detection system of television and infrared sensor, adaptive optical system of Laser atmospheric distortion correction. The development of laser technology is very fast in recent years. A variety of laser sources have been regarded as the key component in many optoelectronic devices. For directed energy weapon, the progress of laser technology has greatly improved the tactical effectiveness, such as increasing the range and strike precision. At the same time, the modern solid-state laser has become the ideal optical source for optical countermeasure, because it has high photoelectric conversion efficiency and small volume or weight. However, the total performance is limited by the mutual cooperation between different subsystems. The optical countermeasure is a complex technique after many years development. The key factor to evaluate the laser weapon can be formulated as laser energy density to target. This article elaborated the laser device technology of optoelectronic countermeasure and Photoelectric tracking technology. Also the allocation of optoelectronic countermeasure was discussed in this article. At last, this article prospected the future development of high-energy laser.

  6. High-sensitivity HLA typing by Saturated Tiling Capture Sequencing (STC-Seq).

    PubMed

    Jiao, Yang; Li, Ran; Wu, Chao; Ding, Yibin; Liu, Yanning; Jia, Danmei; Wang, Lifeng; Xu, Xiang; Zhu, Jing; Zheng, Min; Jia, Junling

    2018-01-15

    Highly polymorphic human leukocyte antigen (HLA) genes are responsible for fine-tuning the adaptive immune system. High-resolution HLA typing is important for the treatment of autoimmune and infectious diseases. Additionally, it is routinely performed for identifying matched donors in transplantation medicine. Although many HLA typing approaches have been developed, the complexity, low-efficiency and high-cost of current HLA-typing assays limit their application in population-based high-throughput HLA typing for donors, which is required for creating large-scale databases for transplantation and precision medicine. Here, we present a cost-efficient Saturated Tiling Capture Sequencing (STC-Seq) approach to capturing 14 HLA class I and II genes. The highly efficient capture (an approximately 23,000-fold enrichment) of these genes allows for simplified allele calling. Tests on five genes (HLA-A/B/C/DRB1/DQB1) from 31 human samples and 351 datasets using STC-Seq showed results that were 98% consistent with the known two sets of digitals (field1 and field2) genotypes. Additionally, STC can capture genomic DNA fragments longer than 3 kb from HLA loci, making the library compatible with the third-generation sequencing. STC-Seq is a highly accurate and cost-efficient method for HLA typing which can be used to facilitate the establishment of population-based HLA databases for the precision and transplantation medicine.

  7. Evaluation of the Precision of Satellite-Derived Sea Surface Temperature Fields

    NASA Astrophysics Data System (ADS)

    Wu, F.; Cornillon, P. C.; Guan, L.

    2016-02-01

    A great deal of attention has been focused on the temporal accuracy of satellite-derived sea surface temperature (SST) fields with little attention being given to their spatial precision. Specifically, the primary measure of the quality of SST fields has been the bias and variance of selected values minus co-located (in space and time) in situ values. Contributing values, determined by the location of the in situ values and the necessity that the satellite-derived values be cloud free, are generally widely separated in space and time hence provide little information related to the pixel-to-pixel uncertainty in the retrievals. But the main contribution to the uncertainty in satellite-derived SST retrievals relates to atmospheric contamination and because the spatial scales of atmospheric features are, in general, large compared with the pixel separation of modern infra-red sensors, the pixel-to-pixel uncertainty is often smaller than the accuracy determined from in situ match-ups. This makes selection of satellite-derived datasets for the study of submesoscale processes, for which the spatial structure of the upper ocean is significant, problematic. In this presentation we present a methodology to characterize the spatial precision of satellite-derived SST fields. The method is based on an examination of the high wavenumber tail of the 2-D spectrum of SST fields in the Sargasso Sea, a low energy region of the ocean close to the track of the MV Oleander, a container ship making weekly roundtrips between New York and Bermuda, with engine intake temperatures sampled every 75 m along track. Important spectral characteristics are the point at which the satellite-derived spectra separate from the Oleander spectra and the spectral slope following separation. In this presentation a number of high resolution 375 m to 10 km SST datasets are evaluated based on this approach.

  8. The shortest path is not the one you know: application of biological network resources in precision oncology research.

    PubMed

    Kuperstein, Inna; Grieco, Luca; Cohen, David P A; Thieffry, Denis; Zinovyev, Andrei; Barillot, Emmanuel

    2015-03-01

    Several decades of molecular biology research have delivered a wealth of detailed descriptions of molecular interactions in normal and tumour cells. This knowledge has been functionally organised and assembled into dedicated biological pathway resources that serve as an invaluable tool, not only for structuring the information about molecular interactions but also for making it available for biological, clinical and computational studies. With the advent of high-throughput molecular profiling of tumours, close to complete molecular catalogues of mutations, gene expression and epigenetic modifications are available and require adequate interpretation. Taking into account the information about biological signalling machinery in cells may help to better interpret molecular profiles of tumours. Making sense out of these descriptions requires biological pathway resources for functional interpretation of the data. In this review, we describe the available biological pathway resources, their characteristics in terms of construction mode, focus, aims and paradigms of biological knowledge representation. We present a new resource that is focused on cancer-related signalling, the Atlas of Cancer Signalling Networks. We briefly discuss current approaches for data integration, visualisation and analysis, using biological networks, such as pathway scoring, guilt-by-association and network propagation. Finally, we illustrate with several examples the added value of data interpretation in the context of biological networks and demonstrate that it may help in analysis of high-throughput data like mutation, gene expression or small interfering RNA screening and can guide in patients stratification. Finally, we discuss perspectives for improving precision medicine using biological network resources and tools. Taking into account the information about biological signalling machinery in cells may help to better interpret molecular patterns of tumours and enable to put precision oncology into general clinical practice. © The Author 2015. Published by Oxford University Press on behalf of the UK Environmental Mutagen Society. All rights reserved. For permissions, please e-mail: journals.permissions@oup.com.

  9. Approximate Single-Diode Photovoltaic Model for Efficient I-V Characteristics Estimation

    PubMed Central

    Ting, T. O.; Zhang, Nan; Guan, Sheng-Uei; Wong, Prudence W. H.

    2013-01-01

    Precise photovoltaic (PV) behavior models are normally described by nonlinear analytical equations. To solve such equations, it is necessary to use iterative procedures. Aiming to make the computation easier, this paper proposes an approximate single-diode PV model that enables high-speed predictions for the electrical characteristics of commercial PV modules. Based on the experimental data, statistical analysis is conducted to validate the approximate model. Simulation results show that the calculated current-voltage (I-V) characteristics fit the measured data with high accuracy. Furthermore, compared with the existing modeling methods, the proposed model reduces the simulation time by approximately 30% in this work. PMID:24298205

  10. Analysis and Compensation of Modulation Angular Rate Error Based on Missile-Borne Rotation Semi-Strapdown Inertial Navigation System.

    PubMed

    Zhang, Jiayu; Li, Jie; Zhang, Xi; Che, Xiaorui; Huang, Yugang; Feng, Kaiqiang

    2018-05-04

    The Semi-Strapdown Inertial Navigation System (SSINS) provides a new solution to attitude measurement of a high-speed rotating missile. However, micro-electro-mechanical-systems (MEMS) inertial measurement unit (MIMU) outputs are corrupted by significant sensor errors. In order to improve the navigation precision, a rotation modulation technology method called Rotation Semi-Strapdown Inertial Navigation System (RSSINS) is introduced into SINS. In fact, the stability of the modulation angular rate is difficult to achieve in a high-speed rotation environment. The changing rotary angular rate has an impact on the inertial sensor error self-compensation. In this paper, the influence of modulation angular rate error, including acceleration-deceleration process, and instability of the angular rate on the navigation accuracy of RSSINS is deduced and the error characteristics of the reciprocating rotation scheme are analyzed. A new compensation method is proposed to remove or reduce sensor errors so as to make it possible to maintain high precision autonomous navigation performance by MIMU when there is no external aid. Experiments have been carried out to validate the performance of the method. In addition, the proposed method is applicable for modulation angular rate error compensation under various dynamic conditions.

  11. The Accuracy and Precision of Position and Orientation Tracking in the HTC Vive Virtual Reality System for Scientific Research

    PubMed Central

    Niehorster, Diederick C.; Li, Li; Lappe, Markus

    2017-01-01

    The advent of inexpensive consumer virtual reality equipment enables many more researchers to study perception with naturally moving observers. One such system, the HTC Vive, offers a large field-of-view, high-resolution head mounted display together with a room-scale tracking system for less than a thousand U.S. dollars. If the position and orientation tracking of this system is of sufficient accuracy and precision, it could be suitable for much research that is currently done with far more expensive systems. Here we present a quantitative test of the HTC Vive’s position and orientation tracking as well as its end-to-end system latency. We report that while the precision of the Vive’s tracking measurements is high and its system latency (22 ms) is low, its position and orientation measurements are provided in a coordinate system that is tilted with respect to the physical ground plane. Because large changes in offset were found whenever tracking was briefly lost, it cannot be corrected for with a one-time calibration procedure. We conclude that the varying offset between the virtual and the physical tracking space makes the HTC Vive at present unsuitable for scientific experiments that require accurate visual stimulation of self-motion through a virtual world. It may however be suited for other experiments that do not have this requirement. PMID:28567271

  12. Design of FHiRE: the Fiber High Resolution Echelle Spectrograph

    NASA Astrophysics Data System (ADS)

    Pierce, Michael J.; McLane, Jacob N.; Pilachowski, C. A.; Kobulnicky, Henry; Jang-Condell, Hannah

    2018-01-01

    The enormous success of the Kepler mission in the discovery of transiting exoplanets implies that the majority of stars have planetary systems. NASA's upcomming Transiting Exoplanet Survey Satellite (TESS) is designed to survey the brightest stars over the entire sky, systems that are accessible to spectroscopic follow-up with mid-sized telescopes. We have undertaken the development of a precision radial velocity spectrograph with the goal of providing ground-based suppoert for TESS. The instrument, known as FHiRE (Fiber High Resolution Echelle spectrograph), is being developed in collaboration with Indiana University and will deployed at the 2.3-meter telescope of the Wyoming InfraRed Observatory (WIRO). FHiRE features a traditional white pupil echelle design with R ~ 60,000 that is fed via two optical fibers from the telescope. Both the science fiber and a simultaneously sampled Thorium-Argon comparison fiber will make use of double mode scramblers. FHiRE itself will be housed within a vacuum enclosure in order to minimize any temperatue variations of the instrument and maximize its radial velocity precision. Together, these two features should enable FHiRE to reach a long-term velocity precision of < 1 m/s. We present the design of FHiRE and its expected performance. In a companion poster (Jang-Condell et al.) we will present the exoplanet science goals of the project.

  13. Markov random field based automatic image alignment for electron tomography.

    PubMed

    Amat, Fernando; Moussavi, Farshid; Comolli, Luis R; Elidan, Gal; Downing, Kenneth H; Horowitz, Mark

    2008-03-01

    We present a method for automatic full-precision alignment of the images in a tomographic tilt series. Full-precision automatic alignment of cryo electron microscopy images has remained a difficult challenge to date, due to the limited electron dose and low image contrast. These facts lead to poor signal to noise ratio (SNR) in the images, which causes automatic feature trackers to generate errors, even with high contrast gold particles as fiducial features. To enable fully automatic alignment for full-precision reconstructions, we frame the problem probabilistically as finding the most likely particle tracks given a set of noisy images, using contextual information to make the solution more robust to the noise in each image. To solve this maximum likelihood problem, we use Markov Random Fields (MRF) to establish the correspondence of features in alignment and robust optimization for projection model estimation. The resulting algorithm, called Robust Alignment and Projection Estimation for Tomographic Reconstruction, or RAPTOR, has not needed any manual intervention for the difficult datasets we have tried, and has provided sub-pixel alignment that is as good as the manual approach by an expert user. We are able to automatically map complete and partial marker trajectories and thus obtain highly accurate image alignment. Our method has been applied to challenging cryo electron tomographic datasets with low SNR from intact bacterial cells, as well as several plastic section and X-ray datasets.

  14. The Accuracy and Precision of Position and Orientation Tracking in the HTC Vive Virtual Reality System for Scientific Research.

    PubMed

    Niehorster, Diederick C; Li, Li; Lappe, Markus

    2017-01-01

    The advent of inexpensive consumer virtual reality equipment enables many more researchers to study perception with naturally moving observers. One such system, the HTC Vive, offers a large field-of-view, high-resolution head mounted display together with a room-scale tracking system for less than a thousand U.S. dollars. If the position and orientation tracking of this system is of sufficient accuracy and precision, it could be suitable for much research that is currently done with far more expensive systems. Here we present a quantitative test of the HTC Vive's position and orientation tracking as well as its end-to-end system latency. We report that while the precision of the Vive's tracking measurements is high and its system latency (22 ms) is low, its position and orientation measurements are provided in a coordinate system that is tilted with respect to the physical ground plane. Because large changes in offset were found whenever tracking was briefly lost, it cannot be corrected for with a one-time calibration procedure. We conclude that the varying offset between the virtual and the physical tracking space makes the HTC Vive at present unsuitable for scientific experiments that require accurate visual stimulation of self-motion through a virtual world. It may however be suited for other experiments that do not have this requirement.

  15. Measuring Spray Droplet Size from Agricultural Nozzles Using Laser Diffraction

    PubMed Central

    Fritz, Bradley K.; Hoffmann, W. Clint

    2016-01-01

    When making an application of any crop protection material such as an herbicide or pesticide, the applicator uses a variety of skills and information to make an application so that the material reaches the target site (i.e., plant). Information critical in this process is the droplet size that a particular spray nozzle, spray pressure, and spray solution combination generates, as droplet size greatly influences product efficacy and how the spray moves through the environment. Researchers and product manufacturers commonly use laser diffraction equipment to measure the spray droplet size in laboratory wind tunnels. The work presented here describes methods used in making spray droplet size measurements with laser diffraction equipment for both ground and aerial application scenarios that can be used to ensure inter- and intra-laboratory precision while minimizing sampling bias associated with laser diffraction systems. Maintaining critical measurement distances and concurrent airflow throughout the testing process is key to this precision. Real time data quality analysis is also critical to preventing excess variation in the data or extraneous inclusion of erroneous data. Some limitations of this method include atypical spray nozzles, spray solutions or application conditions that result in spray streams that do not fully atomize within the measurement distances discussed. Successful adaption of this method can provide a highly efficient method for evaluation of the performance of agrochemical spray application nozzles under a variety of operational settings. Also discussed are potential experimental design considerations that can be included to enhance functionality of the data collected. PMID:27684589

  16. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Hoegg, Edward D.; Barinaga, Charles J.; Hager, George J.

    Abstract The continued development of the liquid sampling-atmospheric pressure glow discharge (LS-APGD) microplasma as an ion source for diverse, elemental/isotopic analysis applications continues. To this end, characterization of the capabilities in performing precise and accurate isotope ratio (IR) determinations is essential. Based on past experience with the Thermo Exactive Orbitrap mass analyzer, the LS-APGD was interfaced with this instrument for these tests. While the Orbitrap platform has demonstrated excellent mass resolution and accuracy in “organic” mass spectrometry (MS) applications, work using an Orbitrap for IR analysis is very sparse. These efforts build off previous work in this coupling, where themore » importance of a few of the LS-APGD discharge parameters and Orbitrap data acquisition methods on IR precision and accuracy were probed. Presented here are the results of a study that evaluated the analytical precision for natural uranium sample (assumed 235U/238U = 0.0072) determinations. The instrumental parameters evaluated include the number of microscans and scans making up a data acquisition set, uranium concentration/signal level, sample make-up, and Fourier transform digitization window. Ultimately, a precision of 0.41% relative standard deviation (RSD) can be achieved for a single determination, with a reproducibility of 1.63 %RSD over 10 separate analytical measurements. A preliminary study of matrix effects on IR measurements of U is presented, highlighting the importance of pre-mass selection before injection into the Orbitrap. The analytical system sensitivity is suggested with the ability to produce a calibration function having an R2 value of >0.99 over a range of 4 orders of magnitude of concentration (~1 – 1000 ng mL-1). These efforts demonstrate the very promising pairing of the LS-APGD ionization source and the Orbitrap, pointing as well to definitive paths forward to better utilize both components in high quality isotope ratio mass spectrometry (IRMS).« less

  17. Semantic Health Knowledge Graph: Semantic Integration of Heterogeneous Medical Knowledge and Services.

    PubMed

    Shi, Longxiang; Li, Shijian; Yang, Xiaoran; Qi, Jiaheng; Pan, Gang; Zhou, Binbin

    2017-01-01

    With the explosion of healthcare information, there has been a tremendous amount of heterogeneous textual medical knowledge (TMK), which plays an essential role in healthcare information systems. Existing works for integrating and utilizing the TMK mainly focus on straightforward connections establishment and pay less attention to make computers interpret and retrieve knowledge correctly and quickly. In this paper, we explore a novel model to organize and integrate the TMK into conceptual graphs. We then employ a framework to automatically retrieve knowledge in knowledge graphs with a high precision. In order to perform reasonable inference on knowledge graphs, we propose a contextual inference pruning algorithm to achieve efficient chain inference. Our algorithm achieves a better inference result with precision and recall of 92% and 96%, respectively, which can avoid most of the meaningless inferences. In addition, we implement two prototypes and provide services, and the results show our approach is practical and effective.

  18. Semantic Health Knowledge Graph: Semantic Integration of Heterogeneous Medical Knowledge and Services

    PubMed Central

    Yang, Xiaoran; Qi, Jiaheng; Pan, Gang; Zhou, Binbin

    2017-01-01

    With the explosion of healthcare information, there has been a tremendous amount of heterogeneous textual medical knowledge (TMK), which plays an essential role in healthcare information systems. Existing works for integrating and utilizing the TMK mainly focus on straightforward connections establishment and pay less attention to make computers interpret and retrieve knowledge correctly and quickly. In this paper, we explore a novel model to organize and integrate the TMK into conceptual graphs. We then employ a framework to automatically retrieve knowledge in knowledge graphs with a high precision. In order to perform reasonable inference on knowledge graphs, we propose a contextual inference pruning algorithm to achieve efficient chain inference. Our algorithm achieves a better inference result with precision and recall of 92% and 96%, respectively, which can avoid most of the meaningless inferences. In addition, we implement two prototypes and provide services, and the results show our approach is practical and effective. PMID:28299322

  19. Efficient generation of mouse models of human diseases via ABE- and BE-mediated base editing.

    PubMed

    Liu, Zhen; Lu, Zongyang; Yang, Guang; Huang, Shisheng; Li, Guanglei; Feng, Songjie; Liu, Yajing; Li, Jianan; Yu, Wenxia; Zhang, Yu; Chen, Jia; Sun, Qiang; Huang, Xingxu

    2018-06-14

    A recently developed adenine base editor (ABE) efficiently converts A to G and is potentially useful for clinical applications. However, its precision and efficiency in vivo remains to be addressed. Here we achieve A-to-G conversion in vivo at frequencies up to 100% by microinjection of ABE mRNA together with sgRNAs. We then generate mouse models harboring clinically relevant mutations at Ar and Hoxd13, which recapitulates respective clinical defects. Furthermore, we achieve both C-to-T and A-to-G base editing by using a combination of ABE and SaBE3, thus creating mouse model harboring multiple mutations. We also demonstrate the specificity of ABE by deep sequencing and whole-genome sequencing (WGS). Taken together, ABE is highly efficient and precise in vivo, making it feasible to model and potentially cure relevant genetic diseases.

  20. Microfabrication of Silicon/Ceramic Hybrid Cantilever for Scanning Probe Microscope and Sensor Applications

    NASA Astrophysics Data System (ADS)

    Wakayama, Takayuki; Kobayashi, Toshinari; Iwata, Nobuya; Tanifuji, Nozomi; Matsuda, Yasuaki; Yamada, Syoji

    2003-12-01

    We present here new cantilevers for scanning probe microscopy (SPM) and sensor applications, which consist of silicon cantilever beam and ceramic pedestal. Silicon is only used to make cantilever beams and tips. Precision-machinery-made ceramics replaces silicon pedestal part. The ceramics was recently developed by Sumikin Ceramics and Quarts Co., Ltd. and can be machined precisely with end mill cutting. Many silicon beams are fabricated at once from a wafer using batch fabrication method. Therefore, SPM probes can be fabricated in high productivity and in low cost. These beams are transferred with transfer technique and are bonded on the ceramic pedestal with epoxy glue. We demonstrate here atomic force microscope (AFM) and gas sensor applications of the hybrid structure. In a gas sensor application, the ends of the cantilever are selectively modified with zeolite crystals as a sensitive layer. The bonding strength is enough for each application.

  1. Study on SOC wavelet analysis for LiFePO4 battery

    NASA Astrophysics Data System (ADS)

    Liu, Xuepeng; Zhao, Dongmei

    2017-08-01

    Improving the prediction accuracy of SOC can reduce the complexity of the conservative and control strategy of the strategy such as the scheduling, optimization and planning of LiFePO4 battery system. Based on the analysis of the relationship between the SOC historical data and the external stress factors, the SOC Estimation-Correction Prediction Model based on wavelet analysis is established. Using wavelet neural network prediction model is of high precision to achieve forecast link, external stress measured data is used to update parameters estimation in the model, implement correction link, makes the forecast model can adapt to the LiFePO4 battery under rated condition of charge and discharge the operating point of the variable operation area. The test results show that the method can obtain higher precision prediction model when the input and output of LiFePO4 battery are changed frequently.

  2. Evaluation of the accuracy of LF and TV synchronization techniques inChina via portable clock.

    NASA Astrophysics Data System (ADS)

    Miao, Y.-R.; Pan, X.-P.; Song, J.-A.; Bian, Y.-J.; Luo, D.-C.; Zhuang, Q.-X.

    Shanxi, Beijing and Shanghai observatories cooperated with the U. S. Naval Observatory in making two portable clock experiments in 1981 and 1982. A high performance cesium clock was compared with the 1 pps signals from master clock, Loran-C receiver and TV Line-6 receiver in different observatories. The comparison of the experimental results with the prediction of the time delay between transmitter and each observatory indicates that the accuracy of LF synchronization technique in China can reach ±1 μs, timing precision is 0.05 - 0.2 μs at a distance of 2000 km. (It has been shown that there is a systematic error in the Daily Relative Phase Values, Ser. 4 of the U. S. Naval Observatory for the Northwest Pacific Loran-C chain.) For passive CCTV synchronization, timing accuracy is 2 μs or better and daily frequency calibration precision is (2 - 20)×10-13.

  3. Drill Down Tool Evaluation Brief

    ERIC Educational Resources Information Center

    Eliason, Bert; Morris, Kelsey

    2015-01-01

    Data-based decision making is enhanced by identifying a precise problem statement or question to explore. When looking at a problem, the nearer we get to the precise problem (e.g., where and when it is occurring, who is involved, and why the problem is continuing in context and location) the more quickly we can build an action plan to effectively…

  4. The MINERvA Experiment

    NASA Astrophysics Data System (ADS)

    Betancourt, Minerba; Minerva Collaboration

    2017-01-01

    MINERvA is a neutrino scattering experiment to make precision measurements of cross sections and investigate nuclear effects. A precise understanding of neutrino interactions is crucial for the neutrino oscillation program. Several cross sections will be presented, including pion production, kaon production as well as direct comparisons of the same process on different nuclei. Comparisons with theoretical models are reported.

  5. Trace element analysis by EPMA in geosciences: detection limit, precision and accuracy

    NASA Astrophysics Data System (ADS)

    Batanova, V. G.; Sobolev, A. V.; Magnin, V.

    2018-01-01

    Use of the electron probe microanalyser (EPMA) for trace element analysis has increased over the last decade, mainly because of improved stability of spectrometers and the electron column when operated at high probe current; development of new large-area crystal monochromators and ultra-high count rate spectrometers; full integration of energy-dispersive / wavelength-dispersive X-ray spectrometry (EDS/WDS) signals; and the development of powerful software packages. For phases that are stable under a dense electron beam, the detection limit and precision can be decreased to the ppm level by using high acceleration voltage and beam current combined with long counting time. Data on 10 elements (Na, Al, P, Ca, Ti, Cr, Mn, Co, Ni, Zn) in olivine obtained on a JEOL JXA-8230 microprobe with tungsten filament show that the detection limit decreases proportionally to the square root of counting time and probe current. For all elements equal or heavier than phosphorus (Z = 15), the detection limit decreases with increasing accelerating voltage. The analytical precision for minor and trace elements analysed in olivine at 25 kV accelerating voltage and 900 nA beam current is 4 - 18 ppm (2 standard deviations of repeated measurements of the olivine reference sample) and is similar to the detection limit of corresponding elements. To analyse trace elements accurately requires careful estimation of background, and consideration of sample damage under the beam and secondary fluorescence from phase boundaries. The development and use of matrix reference samples with well-characterised trace elements of interest is important for monitoring and improving of the accuracy. An evaluation of the accuracy of trace element analyses in olivine has been made by comparing EPMA data for new reference samples with data obtained by different in-situ and bulk analytical methods in six different laboratories worldwide. For all elements, the measured concentrations in the olivine reference sample were found to be identical (within internal precision) to reference values, suggesting that achieved precision and accuracy are similar. The spatial resolution of EPMA in a silicate matrix, even at very extreme conditions (accelerating voltage 25 kV), does not exceed 7 - 8 μm and thus is still better than laser ablation inductively coupled plasma mass spectrometry (LA-ICP-MS) or secondary ion mass spectrometry (SIMS) of similar precision. These make the electron microprobe an indispensable method with applications in experimental petrology, geochemistry and cosmochemistry.

  6. High-precision Orbit Fitting and Uncertainty Analysis of (486958) 2014 MU69

    NASA Astrophysics Data System (ADS)

    Porter, Simon B.; Buie, Marc W.; Parker, Alex H.; Spencer, John R.; Benecchi, Susan; Tanga, Paolo; Verbiscer, Anne; Kavelaars, J. J.; Gwyn, Stephen D. J.; Young, Eliot F.; Weaver, H. A.; Olkin, Catherine B.; Parker, Joel W.; Stern, S. Alan

    2018-07-01

    NASA’s New Horizons spacecraft will conduct a close flyby of the cold-classical Kuiper Belt Object (KBO) designated (486958) 2014 MU69 on 2019 January 1. At a heliocentric distance of 44 au, “MU69” will be the most distant object ever visited by a spacecraft. To enable this flyby, we have developed an extremely high-precision orbit fitting and uncertainty processing pipeline, making maximal use of the Hubble Space Telescope’s Wide Field Camera 3 (WFC3) and pre-release versions of the ESA Gaia Data Release 2 (DR2) catalog. This pipeline also enabled successful predictions of a stellar occultation by MU69 in 2017 July. We describe how we process the WFC3 images to match the Gaia DR2 catalog, extract positional uncertainties for this extremely faint target (typically 140 photons per WFC3 exposure), and translate those uncertainties into probability distribution functions for MU69 at any given time. We also describe how we use these uncertainties to guide New Horizons, plan stellar occultions of MU69, and derive MU69's orbital evolution and long-term stability.

  7. Electrodeposition of organic-inorganic tri-halide perovskites solar cell

    NASA Astrophysics Data System (ADS)

    Charles, U. A.; Ibrahim, M. A.; Teridi, M. A. M.

    2018-02-01

    Perovskite (CH3NH3PbI3) semiconductor materials are promising high-performance light energy absorber for solar cell application. However, the power conversion efficiency of perovskite solar cell is severely affected by the surface quality of the deposited thin film. Spin coating is a low-cost and widely used deposition technique for perovskite solar cell. Notably, film deposited by spin coating evolves surface hydroxide and defeats from uncontrolled precipitation and inter-diffusion reaction. Alternatively, vapor deposition (VD) method produces uniform thin film but requires precise control of complex thermodynamic parameters which makes the technique unsuitable for large scale production. Most deposition techniques for perovskite require tedious surface optimization to improve the surface quality of deposits. Optimization of perovskite surface is necessary to significantly improve device structure and electrical output. In this review, electrodeposition of perovskite solar cell is demonstrated as a scalable and reproducible technique to fabricate uniform and smooth thin film surface that circumvents the need for high vacuum environment. Electrodeposition is achieved at low temperatures, supports precise control and optimization of deposits for efficient charge transfer.

  8. Probing M Dwarf Model-Data Discrepancies via Precise, Empirical Characterization of a Long-Period F+M Binary

    NASA Astrophysics Data System (ADS)

    Stevens, Daniel; Gaudi, Scott; Beatty, Thomas; Siverd, Robert

    2018-05-01

    Double-lined eclipsing binaries (EBs) have been the gold standard for direct, precise (less than a few percent), and accurate measurements of stellar masses and radii. However, with the availability of Gaia parallaxes and nearly complete spectral energy distributions (SEDs) of millions of stars, it will soon be possible to make such measurements for the much larger number of single-lined EBs such as high mass-ratio systems and transiting planets, both of which are routinely found by transit surveys. Combining high-precision eclipse photometry and radial velocity (RV) observations of the primary star enables measurements of the primary star's density, the ratio of stellar radii, and a combination of the stars' masses. Broad-band photometry from the ultraviolet to the infrared plus a Gaia parallax and an effective temperature of the primary from either the SED or high-resolution spectra, allow one to measure the radius (and mass via the density) of the primary. The radius and mass of the secondary can then be determined in the usual way with the radius ratio and RVs, and the companion's effective temperature can be determined from a secondary eclipse measurement and the primary star's effective temperature. For single-lined EBs, the precision of ingress/egress duration measurements dominates the error budget of the masses and companion radius. We propose to observe one primary and secondary eclipse of the F+M binary TYC 4223-1012-1, an M dwarf on a 16.5-day orbit around an F dwarf. Ground-based data poorly constrain TYC 4223-1012-1's masses due to the near-impossibility of observing the full 10-hr eclipse from the ground. By combining extant RV and SED data with the Spitzer data, we expect to measure the mass, radius, and effective temperature of the M dwarf to a few percent. This is comparable to the precision of the best-characterized literature M dwarfs, but at an orbital period far beyond the majority of such systems, where tidal effects should be negligible.

  9. A high-speed tracking algorithm for dense granular media

    NASA Astrophysics Data System (ADS)

    Cerda, Mauricio; Navarro, Cristóbal A.; Silva, Juan; Waitukaitis, Scott R.; Mujica, Nicolás; Hitschfeld, Nancy

    2018-06-01

    Many fields of study, including medical imaging, granular physics, colloidal physics, and active matter, require the precise identification and tracking of particle-like objects in images. While many algorithms exist to track particles in diffuse conditions, these often perform poorly when particles are densely packed together-as in, for example, solid-like systems of granular materials. Incorrect particle identification can have significant effects on the calculation of physical quantities, which makes the development of more precise and faster tracking algorithms a worthwhile endeavor. In this work, we present a new tracking algorithm to identify particles in dense systems that is both highly accurate and fast. We demonstrate the efficacy of our approach by analyzing images of dense, solid-state granular media, where we achieve an identification error of 5% in the worst evaluated cases. Going further, we propose a parallelization strategy for our algorithm using a GPU, which results in a speedup of up to 10 × when compared to a sequential CPU implementation in C and up to 40 × when compared to the reference MATLAB library widely used for particle tracking. Our results extend the capabilities of state-of-the-art particle tracking methods by allowing fast, high-fidelity detection in dense media at high resolutions.

  10. Modeling applications for precision agriculture in the California Central Valley

    NASA Astrophysics Data System (ADS)

    Marklein, A. R.; Riley, W. J.; Grant, R. F.; Mezbahuddin, S.; Mekonnen, Z. A.; Liu, Y.; Ying, S.

    2017-12-01

    Drought in California has increased the motivation to develop precision agriculture, which uses observations to make site-specific management decisions throughout the growing season. In agricultural systems that are prone to drought, these efforts often focus on irrigation efficiency. Recent improvements in soil sensor technology allow the monitoring of plant and soil status in real-time, which can then inform models aimed at improving irrigation management. But even on farms with resources to deploy soil sensors across the landscape, leveraging that sensor data to design an efficient irrigation scheme remains a challenge. We conduct a modeling experiment aimed at simulating precision agriculture to address several questions: (1) how, when, and where does irrigation lead to optimal yield? and (2) What are the impacts of different precision irrigation schemes on yields, soil organic carbon (SOC), and total water use? We use the ecosys model to simulate precision agriculture in a conventional tomato-corn rotation in the California Central Valley with varying soil water content thresholds for irrigation and soil water sensor depths. This model is ideal for our question because it includes explicit process-based functions for the plant growth, plant water use, soil hydrology, and SOC, and has been tested extensively in agricultural ecosystems. Low irrigation thresholds allows the soil to become drier before irrigating compared to high irrigation thresholds; as such, we found that the high irrigation thresholds use more irrigation over the course of the season, have higher yields, and have lower water use efficiency. The irrigation threshold did not affect SOC. Yields and water use are highest at sensor depths of 0.5 to 0.15 m, but water use efficiency was also lowest at these depths. We found SOC to be significantly affected by sensor depth, with the highest SOC at the shallowest sensor depths. These results will help regulate irrigation water while maintaining yield in California, especially with uncertain precipitation regimes.

  11. Temporal competition between differentiation programs determines cell fate choice

    NASA Astrophysics Data System (ADS)

    Kuchina, Anna; Espinar, Lorena; Cagatay, Tolga; Balbin, Alejandro; Alvarado, Alma; Garcia-Ojalvo, Jordi; Suel, Gurol

    2011-03-01

    During pluripotent differentiation, cells adopt one of several distinct fates. The dynamics of this decision-making process are poorly understood, since cell fate choice may be governed by interactions between differentiation programs that are active at the same time. We studied the dynamics of decision-making in the model organism Bacillus subtilis by simultaneously measuring the activities of competing differentiation programs (sporulation and competence) in single cells. We discovered a precise switch-like point of cell fate choice previously hidden by cell-cell variability. Engineered artificial crosslinks between competence and sporulation circuits revealed that the precision of this choice is generated by temporal competition between the key players of two differentiation programs. Modeling suggests that variable progression towards a switch-like decision might represent a general strategy to maximize adaptability and robustness of cellular decision-making.

  12. Isotopic Analysis of Plutonium by Optical Spectroscopy; ANALYSE ISOTOPIQUE DU PLUTONIUM PAR SPECTROSCOPIE OPTIQUE

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Artaud, J.; Chaput, M.; Gerstenkorn, S.

    1961-01-01

    Isotopic analyses of mixtures of plutonium-239 and -240 were carried out by means of the photoelectric spectrometer, the source being a hollow cathode cooled by liquid nitrogen. The relative precision is of the order of 2%, for samples containieg 3% of Pu/sup 240/. The study of the reproductibility of the measurements should make it possible to increase the precision; the relative precision which can be expected from the method should be 1% for mixtures containing 1% of Pu/sup 240/. (auth)

  13. Chapter 9: "I Want to Make a Difference"

    ERIC Educational Resources Information Center

    Roholt, Ross VeLure; Hildreth, R. W.; Baizerman, Michael

    2007-01-01

    "I want to make a difference," say young people involved in Youth-in-Government, Public Achievement, and Youth Science Center. And we believe that they mean it. Indeed, the power and meaning of these projects lies in the spaces each creates for young people to do precisely that-work on meaningful issues on which they can "make a difference" beyond…

  14. Gamma astrometric measurement experiment -science and implementation

    NASA Astrophysics Data System (ADS)

    Gai, Mario; Vecchiato, Alberto; Lattanzi, Mario G.; Ligori, Sebastiano; Loreggia, Davide; Fineschi, Silvano

    GAME (Gamma Astrometric Measurement Experiment) is a mission concept taking advantage of astronomical techniques for high precision measurements of interest to Fundamental Physics, and in particular the γ parameter of the Parameterized Post-Newtonian formulation of gravi-tation theories modifying the General Relativity. A space based telescope, looking close to the Solar limb thanks to coronagraphic techniques, may implement astrometric measurements sim-ilar to those performed in the solar eclipse of 1919, when Dyson, Eddington and collaborators measured for the first time the gravitational bending of light. Simulations show that the final accuracy of GAME can reach the 10-7 level. GAME will be a decisive experiment for the understanding of gravity physics, cosmology and the Universe evolution. The observations leading to Dark Matter (e.g. galaxy rotation curves) and Dark Energy (accelerated expansion of the Universe) might be explained with a modified version of General Relativity, e.g. in which the curvature invariant R is no longer constant as in Einstein's equations, i.e. the f (R) gravity theories. A 10-7 level determination of γ will provide stringent constraints on acceptable theories. Also, high precision astrometry makes accessible other appealing measurements, e.g. the light deflection induced by the quadrupole moment of giant planets, like Jupiter or Saturn, and, by high precision determination of the orbits of Mercury and high elongation asteroids, the PPN parameter β. GAME may also carry out measurements on selected astrophysical targets, e.g. nearby, bright stars known to host companions with minimum masses in the planetary/brown dwarf regime, and orbital radii in the 3-7 AU range, which are observed by no other present or planned campaigns. GAME, also thanks to high-cadence, high-precision photometry on transit-ing exoplanet systems, will thus improve on our understanding of the actual mass distribution and multiplicity of sub-stellar companions. The GAME measurement principle is based on the differential astrometric signature on the stellar positions. Calibration is implemented by observation of stellar fields affected by neg-ligible deflection. The instrument concept is based on a dual field, multiple aperture Fizeau interferometer, observing simultaneously sky regions close to the Solar limb. Coronagraphic solutions are embedded in the astrometric telescope design, to achieve a rejection factor of the Sun disk and stray light of ˜ 10-9 . An array of apertures implemented by pupil masking on an underlying telescope with primary diameter below one meter, with long focal length, fulfills the mission specifications by providing individual photo-center precision better than 1 milli-arcsecond for source magnitude 15 or brighter.

  15. [Flexible print circuit technology application in biomedical engineering].

    PubMed

    Jiang, Lihua; Cao, Yi; Zheng, Xiaolin

    2013-06-01

    Flexible print circuit (FPC) technology has been widely applied in variety of electric circuits with high precision due to its advantages, such as low-cost, high specific fabrication ability, and good flexibility, etc. Recently, this technology has also been used in biomedical engineering, especially in the development of microfluidic chip and microelectrode array. The high specific fabrication can help making microelectrode and other micro-structure equipment. And good flexibility allows the micro devices based on FPC technique to be easily packaged with other parts. In addition, it also reduces the damage of microelectrodes to the tissue. In this paper, the application of FPC technology in biomedical engineering is introduced. Moreover, the important parameters of FPC technique and the development trend of prosperous applications is also discussed.

  16. A classification model of Hyperion image base on SAM combined decision tree

    NASA Astrophysics Data System (ADS)

    Wang, Zhenghai; Hu, Guangdao; Zhou, YongZhang; Liu, Xin

    2009-10-01

    Monitoring the Earth using imaging spectrometers has necessitated more accurate analyses and new applications to remote sensing. A very high dimensional input space requires an exponentially large amount of data to adequately and reliably represent the classes in that space. On the other hand, with increase in the input dimensionality the hypothesis space grows exponentially, which makes the classification performance highly unreliable. Traditional classification algorithms Classification of hyperspectral images is challenging. New algorithms have to be developed for hyperspectral data classification. The Spectral Angle Mapper (SAM) is a physically-based spectral classification that uses an ndimensional angle to match pixels to reference spectra. The algorithm determines the spectral similarity between two spectra by calculating the angle between the spectra, treating them as vectors in a space with dimensionality equal to the number of bands. The key and difficulty is that we should artificial defining the threshold of SAM. The classification precision depends on the rationality of the threshold of SAM. In order to resolve this problem, this paper proposes a new automatic classification model of remote sensing image using SAM combined with decision tree. It can automatic choose the appropriate threshold of SAM and improve the classify precision of SAM base on the analyze of field spectrum. The test area located in Heqing Yunnan was imaged by EO_1 Hyperion imaging spectrometer using 224 bands in visual and near infrared. The area included limestone areas, rock fields, soil and forests. The area was classified into four different vegetation and soil types. The results show that this method choose the appropriate threshold of SAM and eliminates the disturbance and influence of unwanted objects effectively, so as to improve the classification precision. Compared with the likelihood classification by field survey data, the classification precision of this model heightens 9.9%.

  17. Superallowed nuclear beta decay: Precision measurements for basic physics

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Hardy, J. C.

    2012-11-20

    For 60 years, superallowed 0{sup +}{yields}0{sup +} nuclear beta decay has been used to probe the weak interaction, currently verifying the conservation of the vector current (CVC) to high precision ({+-}0.01%) and anchoring the most demanding available test of the unitarity of the Cabibbo-Kobayashi-Maskawa (CKM) matrix ({+-}0.06%), a fundamental pillar of the electroweak standard model. Each superallowed transition is characterized by its ft-value, a result obtained from three measured quantities: the total decay energy of the transition, its branching ratio, and the half-life of the parent state. Today's data set is composed of some 150 independent measurements of 13 separatemore » superallowed transitions covering a wide range of parent nuclei from {sup 10}C to {sup 74}Rb. Excellent consistency among the average results for all 13 transitions - a prediction of CVC - also confirms the validity of the small transition-dependent theoretical corrections that have been applied to account for isospin symmetry breaking. With CVC consistency established, the value of the vector coupling constant, G{sub V}, has been extracted from the data and used to determine the top left element of the CKM matrix, V{sub ud}. With this result the top-row unitarity test of the CKM matrix yields the value 0.99995(61), a result that sets a tight limit on possible new physics beyond the standard model. To have any impact on these fundamental weak-interaction tests, any measurement must be made with a precision of 0.1% or better - a substantial experimental challenge well beyond the requirements of most nuclear physics measurements. I overview the current state of the field and outline some of the requirements that need to be met by experimentalists if they aim to make measurements with this high level of precision.« less

  18. H3Africa: current perspectives

    PubMed Central

    Mulder, Nicola; Abimiku, Alash’le; Adebamowo, Sally N; de Vries, Jantina; Matimba, Alice; Olowoyo, Paul; Ramsay, Michele; Skelton, Michelle; Stein, Dan J

    2018-01-01

    Precision medicine is being enabled in high-income countries by the growing availability of health data, increasing knowledge of the genetic determinants of disease and variation in response to treatment (pharmacogenomics), and the decreasing costs of data generation, which promote routine application of genomic technologies in the health sector. However, there is uncertainty about the feasibility of applying precision medicine approaches in low- and middle-income countries, due to the lack of population-specific knowledge, skills, and resources. The Human Heredity and Health in Africa (H3Africa) initiative was established to drive new research into the genetic and environmental basis for human diseases of relevance to Africans as well as to build capacity for genomic research on the continent. Precision medicine requires this capacity, in addition to reference data on local populations, and skills to analyze and interpret genomic data from the bedside. The H3Africa consortium is collectively processing samples and data for over 70,000 participants across the continent, accompanied in most cases by rich clinical information on a variety of non-communicable and infectious diseases. These projects are increasingly providing novel insights into the genetic basis of diseases in indigenous populations, insights that have the potential to drive the development of new diagnostics and treatments. The consortium has also invested significant resources into establishing high-quality biorepositories in Africa, a bioinformatic network, and a strong training program that has developed skills in genomic data analysis and interpretation among bioinformaticians, wet-lab researchers, and health-care professionals. Here, we describe the current perspectives of the H3Africa consortium and how it can contribute to making precision medicine in Africa a reality. PMID:29692621

  19. Clinical applications of virtual navigation bronchial intervention.

    PubMed

    Kajiwara, Naohiro; Maehara, Sachio; Maeda, Junichi; Hagiwara, Masaru; Okano, Tetsuya; Kakihana, Masatoshi; Ohira, Tatsuo; Kawate, Norihiko; Ikeda, Norihiko

    2018-01-01

    In patients with bronchial tumors, we frequently consider endoscopic treatment as the first treatment of choice. All computed tomography (CT) must satisfy several conditions necessary to analyze images by Synapse Vincent. To select safer and more precise approaches for patients with bronchial tumors, we determined the indications and efficacy of virtual navigation intervention for the treatment of bronchial tumors. We examined the efficacy of virtual navigation bronchial intervention for the treatment of bronchial tumors located at a variety of sites in the tracheobronchial tree using a high-speed 3-dimensional (3D) image analysis system, Synapse Vincent. Constructed images can be utilized to decide on the simulation and interventional strategy as well as for navigation during interventional manipulation in two cases. Synapse Vincent was used to determine the optimal planning of virtual navigation bronchial intervention. Moreover, this system can detect tumor location and alsodepict surrounding tissues, quickly, accurately, and safely. The feasibility and safety of Synapse Vincent in performing useful preoperative simulation and navigation of surgical procedures can lead to safer, more precise, and less invasion for the patient, and makes it easy to construct an image, depending on the purpose, in 5-10 minutes using Synapse Vincent. Moreover, if the lesion is in the parenchyma or sub-bronchial lumen, it helps to perform simulation with virtual skeletal subtraction to estimate potential lesion movement. By using virtual navigation system for simulation, bronchial intervention was performed with no complications safely and precisely. Preoperative simulation using virtual navigation bronchial intervention reduces the surgeon's stress levels, particularly when highly skilled techniques are needed to operate on lesions. This task, including both preoperative simulation and intraoperative navigation, leads to greater safety and precision. These technological instruments are helpful for bronchial intervention procedures, and are also excellent devices for educational training.

  20. Supervised Outlier Detection in Large-Scale Mvs Point Clouds for 3d City Modeling Applications

    NASA Astrophysics Data System (ADS)

    Stucker, C.; Richard, A.; Wegner, J. D.; Schindler, K.

    2018-05-01

    We propose to use a discriminative classifier for outlier detection in large-scale point clouds of cities generated via multi-view stereo (MVS) from densely acquired images. What makes outlier removal hard are varying distributions of inliers and outliers across a scene. Heuristic outlier removal using a specific feature that encodes point distribution often delivers unsatisfying results. Although most outliers can be identified correctly (high recall), many inliers are erroneously removed (low precision), too. This aggravates object 3D reconstruction due to missing data. We thus propose to discriminatively learn class-specific distributions directly from the data to achieve high precision. We apply a standard Random Forest classifier that infers a binary label (inlier or outlier) for each 3D point in the raw, unfiltered point cloud and test two approaches for training. In the first, non-semantic approach, features are extracted without considering the semantic interpretation of the 3D points. The trained model approximates the average distribution of inliers and outliers across all semantic classes. Second, semantic interpretation is incorporated into the learning process, i.e. we train separate inlieroutlier classifiers per semantic class (building facades, roof, ground, vegetation, fields, and water). Performance of learned filtering is evaluated on several large SfM point clouds of cities. We find that results confirm our underlying assumption that discriminatively learning inlier-outlier distributions does improve precision over global heuristics by up to ≍ 12 percent points. Moreover, semantically informed filtering that models class-specific distributions further improves precision by up to ≍ 10 percent points, being able to remove very isolated building, roof, and water points while preserving inliers on building facades and vegetation.

  1. Inflatable Hangar for Assembly of Large Structures in Space

    NASA Technical Reports Server (NTRS)

    Wilcox, Brian H.

    2012-01-01

    The NASA Human Space Flight program is interested in projects where humans, beyond low-Earth orbit (LEO), can make an important and unique contribution that cannot be reasonably accomplished purely by robotic means, and is commensurate with the effort and cost associated with human spaceflight. Robotic space telescope missions have been conceived and launched as completed assemblies (e.g., Hubble) or as jack-in-the-box one-time deployments (e.g., James Webb). If it were possible to assemble components of a very large telescope from one or two launches into a telescope that was vastly greater in light-gathering power and resolution, that would constitute a breakthrough. Large telescopes on Earth, like all one-off precision assembly tasks, are done by humans. Humans in shirtsleeves (or cleanroom bunny suits) can perform tasks of remarkable dexterity and precision. Unfortunately, astronauts in pressure suits cannot perform such dexterous and precise tasks because of the limitations of the pressurized gloves. If a large, inflatable hangar were placed in high orbit, along with all the components needed for a large assembly such as a large telescope, then humans in bunny suits could perform the same sorts of extremely precise and dexterous assembly that they could be expected to perform on Earth. Calculations show that such an inflatable hangar, and the necessary gas to make it safe to occupy by shirtsleeves humans wearing oxygen masks, fits within the mass and volume limitations of the proposed "Space Launch System" heavy-lift rocket. A second launch could bring up all the components of an approximately 100-meter-diameter or larger telescope. A large [200 ft (approximately 61 m) in diameter] inflated fabric sphere (or hangar) would contain four humans in bunny suits. The sphere would contain sufficient atmospheric pressure so that spacesuits would not be necessary [about 3.2 psi (approximately 22 kPa)]. The humans would require only oxygen masks and small backpacks similar to SCUBA tanks. The oxygen content of the gas would be about 35%, low enough to reduce fire risk but high enough to sustain life in the event of a failure of an oxygen mask. The bunnysuited astronauts could ride on long "cherry-picker" robots with foot restraints somewhat similar to the arm on the International Space Station. Other astronauts would maneuver freely with small propeller fans on their backpacks to provide thrust in the zero-g environment.

  2. Advancing Precision Nuclear Medicine and Molecular Imaging for Lymphoma.

    PubMed

    Wright, Chadwick L; Maly, Joseph J; Zhang, Jun; Knopp, Michael V

    2017-01-01

    PET with fluorodeoxyglucose F 18 ( 18 F FDG-PET) is a meaningful biomarker for the detection, targeted biopsy, and treatment of lymphoma. This article reviews the evolution of 18 F FDG-PET as a putative biomarker for lymphoma and addresses the current capabilities, challenges, and opportunities to enable precision medicine practices for lymphoma. Precision nuclear medicine is driven by new imaging technologies and methodologies to more accurately detect malignant disease. Although quantitative assessment of response is limited, such technologies will enable a more precise metabolic mapping with much higher definition image detail and thus may make it a robust and valid quantitative response assessment methodology. Copyright © 2016 Elsevier Inc. All rights reserved.

  3. Fission Product Yield Study of 235U, 238U and 239Pu Using Dual-Fission Ionization Chambers

    NASA Astrophysics Data System (ADS)

    Bhatia, C.; Fallin, B.; Howell, C.; Tornow, W.; Gooden, M.; Kelley, J.; Arnold, C.; Bond, E.; Bredeweg, T.; Fowler, M.; Moody, W.; Rundberg, R.; Rusev, G.; Vieira, D.; Wilhelmy, J.; Becker, J.; Macri, R.; Ryan, C.; Sheets, S.; Stoyer, M.; Tonchev, A.

    2014-05-01

    To resolve long-standing differences between LANL and LLNL regarding the correct fission basis for analysis of nuclear test data [M.B. Chadwick et al., Nucl. Data Sheets 111, 2891 (2010); H. Selby et al., Nucl. Data Sheets 111, 2891 (2010)], a collaboration between TUNL/LANL/LLNL has been established to perform high-precision measurements of neutron induced fission product yields. The main goal is to make a definitive statement about the energy dependence of the fission yields to an accuracy better than 2-3% between 1 and 15 MeV, where experimental data are very scarce. At TUNL, we have completed the design, fabrication and testing of three dual-fission chambers dedicated to 235U, 238U, and 239Pu. The dual-fission chambers were used to make measurements of the fission product activity relative to the total fission rate, as well as for high-precision absolute fission yield measurements. The activation method was employed, utilizing the mono-energetic neutron beams available at TUNL. Neutrons of 4.6, 9.0, and 14.5 MeV were produced via the 2H(d,n)3He reaction, and for neutrons at 14.8 MeV, the 3H(d,n)4He reaction was used. After activation, the induced γ-ray activity of the fission products was measured for two months using high-resolution HPGe detectors in a low-background environment. Results for the yield of seven fission fragments of 235U, 238U, and 239Pu and a comparison to available data at other energies are reported. For the first time results are available for neutron energies between 2 and 14 MeV.

  4. Highly conductive metal interconnects on three-dimensional objects fabricated with omnidirectional ink jet printing technology

    NASA Astrophysics Data System (ADS)

    Yoshida, Yasunori; Wada, Hikaru; Izumi, Konami; Tokito, Shizuo

    2017-05-01

    In this work, we demonstrate that highly conductive metal interconnects can be fabricated on the surface of three-dimensional objects using “omnidirectional ink jet” (OIJ) printing technology. OIJ printing technology makes it possible to perform ink jet printing in all directions by combining the motion of a 6-axis vertically articulated robot with precise positioning and a thermal drying process, which allows for the printing of stacked layers. By using OIJ technology, we were the first to successfully fabricate printed interconnect layers having a very low electrical resistance of 12 mΩ over a 10 mm length. Moreover, the results of the high-current test demonstrated that the printed interconnects can withstand high-current-flow of 5 A for 30 min or more.

  5. High temperature aircraft research furnace facilities

    NASA Technical Reports Server (NTRS)

    Smith, James E., Jr.; Cashon, John L.

    1992-01-01

    Focus is on the design, fabrication, and development of the High Temperature Aircraft Research Furnace Facilities (HTARFF). The HTARFF was developed to process electrically conductive materials with high melting points in a low gravity environment. The basic principle of operation is to accurately translate a high temperature arc-plasma gas front as it orbits around a cylindrical sample, thereby making it possible to precisely traverse the entire surface of a sample. The furnace utilizes the gas-tungsten-arc-welding (GTAW) process, also commonly referred to as Tungsten-Inert-Gas (TIG). The HTARFF was developed to further research efforts in the areas of directional solidification, float-zone processing, welding in a low-gravity environment, and segregation effects in metals. The furnace is intended for use aboard the NASA-JSC Reduced Gravity Program KC-135A Aircraft.

  6. The CHEOPS calibration bench

    NASA Astrophysics Data System (ADS)

    Wildi, F.; Chazelas, B.; Deline, A.; Sarajlic, M.; Sordet, M.

    2017-09-01

    CHEOPS is an ESA Class S Mission aiming at the characterization of exoplanets through the precise measurement of their radius, using the transit method [1]. To achieve this goal, the payload is designed to be a high precision "absolute" photometer, looking at one star at a time. It will be able to cover la large fraction of the sky by repointing. Its launch is expected at the end of 2017 [2, this conference]. CHEOPS' main science is the measure of the transit of exoplanets of radius ranging from 1 to 6 Earth radii orbiting bright stars. The required photometric stability to reach this goal is of 20 ppm in 6 hours for a 9th magnitude star. The CHEOPS' only instrument is a Ritchey-Chretien style telescope with 300 mm effective aperture diameter, which provides a defocussed image of the target star on a single frame-transfer backside illuminated CCD detector cooled to -40°C and stabilized within 10 mK [2]. CHEOPS being in a LEO, it is equipped with a high performance baffle. The spacecraft platform provides a pointing stability of < 2 arcsec rms. This relatively modest pointing performance makes high quality flat-fielding necessary In the rest of this article we will refer to the only CHEOPS instrument simply as "CHEOP" Its behavior will be calibrated thoroughly on the ground and only a small subset of the calibrations can be redone in flight. The main focuses of the calibrations are the photonic gain stability and sensibility to the environment variations and the Flat field that has to be known at a precision better than 0.1%.

  7. Design of Feedforward Controller to Reduce Force Ripple for Linear Motor using Halbach Magnet Array with T Shape Magnet

    NASA Astrophysics Data System (ADS)

    Kim, Moojong; Kim, Jinyoung; Lee, Moon G.

    Recently, in micro/nano fabrication equipments, linear motors are widely used as an actuator to position workpiece, machining tool and measurement head. To control them faster and more precise, the motor should have high actuating force and small force ripple. High actuating force enable us to more workpiece with high acceleration. Eventually, it may provide higher throughput. Force ripple gives detrimental effect on the precision and tracking performance of the equipments. In order to accomplish more precise motion, it is important to make lower the force ripple. Force ripple is categorized into cogging and mutual ripple. First is dependent on the shape of magnets and/or core. The second is not dependent on them but dependent on current commutation. In this work, coreless mover i.e. coil winding is applied to the linear motor to avoid the cogging ripple. Therefore, the mutual ripple is only considered to be minimized. Ideal Halbach magnet array has continuously varying magnetization. The THMA (Halbach magnet array with T shape magnets) is proposed to approximate the ideal one. The THMA can not produce ideal sinusoidal flux, therefore, the linear motor with THMA and sinusoidal commutation of current generates the mutual force ripple. In this paper, in order to compensate mutual force ripple by feedforward(FF) controller, we calculate the optimized commutation of input current. The ripple is lower than 1.17% of actuating force if the commutation current agree with the magnetic flux from THMA. The performance of feedforward(FF) controller is verified by experiment.

  8. Some problems concerned with the geodetic use of high precision altimeter data

    NASA Technical Reports Server (NTRS)

    Lelgemann, D.

    1976-01-01

    The definition of the geoid in view of different height systems is discussed. A definition is suggested which makes it possible to take into account the influence of the unknown corrections to the various height systems on the solution of Stokes' problem. A solution to Stokes' problem with an accuracy of 10 cm is derived which allows the inclusion of the results of satellite geodesy. In addition equations are developed for the determination of spherical harmonies using altimeter measurements. The influence of the ellipticity of the reference surface is considered.

  9. [Radiation therapy for cancer--challenges and opportunities].

    PubMed

    Specht, Lena

    2010-02-01

    Radiotherapy for cancer previously employed large treatment fields whereby cures were obtained. However, long-term follow-up documented serious long-term complications due to irradiation of normal tissues. Modern technology makes it possible to very accurately shape the high-dose volume. However, new problems emerge. Organ movement must be managed and the precise definition of the extent of the tumour tissue is crucial. Positron emission tomography and magnetic resonance imaging are increasingly used. Biological imaging may enable us to image tumour biology more accurately and modify radiation doses accordingly.

  10. A Procedure to Determine the Coordinated Chromium and Calcium Isotopic Composition of Astromaterials Including the Chelyabinsk Meteorite

    NASA Technical Reports Server (NTRS)

    Tappa, M. J.; Mills, R. D.; Ware, B.; Simon, J. I.

    2014-01-01

    The isotopic compositions of elements are often used to characterize nucelosynthetic contributions in early Solar System objects. Coordinated multiple middle-mass elements with differing volatilities may provide information regarding the location of condensation of early Solar System solids. Here we detail new procedures that we have developed to make high-precision multi-isotope measurements of chromium and calcium using thermal ionization mass spectrometry, and characterize a suite of chondritic and terrestrial material including two fragments of the Chelyabinsk LL-chondrite.

  11. Development of a scanning transmission x-ray microscope for the beamline P04 at PETRA III DESY

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Andrianov, Konstantin; Ewald, Johannes; Nisius, Thomas

    We present a scanning transmission x-ray microscope (STXM) built on top of our existing modular platform for high resolution imaging experiments. This platform consists of up to three separate vacuum chambers and custom designed piezo stages. These piezo stages are able to move precisely in x-, y- and z-direction, this makes it possible to adjust the components for different imaging modes. During recent experiments the endstation was operated mainly as a transmission x-ray microscope (TXM) [1, 2].

  12. Sub-nm-scale precision stage using nonresonant-ultrasonic motor for making of nanodevices

    NASA Astrophysics Data System (ADS)

    Soh, Y.; Kosaka, K.; Kubota, H.

    2011-12-01

    This paper is focused on piezoelectric actuator for precision stage system which has nano-scale resolution. Nanometer order positioning techniques are necessary for semiconductor manufacturing and its inspection. For these demands, we propose the nonresonant-ultrasonic motor(NRUSM) as driving source of positioning stage. One can use as the stage driving device in a SEM chamber, because NRUSM is non-magnetic device. In addition NRUSM is able to be made compact, can be equipped at various miniature tools, for instance, manipulation, pumping, probing systems, having nano scale resolution. NRUSM is also adopted to Reticle Free Exposure system which can make the flexible patterning by fine displacing of mask patterns. NRUSM's weak point is the occurrence of a wear because of friction caused by the ultrasonic motor. However this wear can be cut down by reducing the slipping. A previously proven effective solution, by which the driving keeps in the range of static friction without the slipping, results in long life time, high-durability and decrease of particles. We propose two solutions to reduce the slipping: driving method and change of structure. The former is control method using variable frequency instead of constant frequency. The latter is increase of friction tips because static frictional force is proportional to number of the tips.

  13. A compact, fast ozone UV photometer and sampling inlet for research aircraft

    NASA Astrophysics Data System (ADS)

    Gao, R. S.; Ballard, J.; Watts, L. A.; Thornberry, T. D.; Ciciora, S. J.; McLaughlin, R. J.; Fahey, D. W.

    2012-05-01

    In situ measurements of atmospheric ozone (O3) are performed routinely from many research aircraft platforms. The most common technique depends on the strong absorption of ultraviolet (UV) light by ozone. As atmospheric science advances to the widespread use of unmanned aircraft systems (UASs), there is an increasing requirement for minimizing instrument space, weight, and power while maintaining instrument accuracy, precision and time response. The design and use of a new, dual-beam, polarized, UV photometer instrument for in situ O3 measurements is described. The instrument has a fast sampling rate (2 Hz), high accuracy (3%), and precision (1.1 × 1010 O3 molecules cm-3). The size (36 l), weight (18 kg), and power (50-200 W) make the instrument suitable for many UAS and other airborne platforms. Inlet and exhaust configurations are also described for ambient sampling in the troposphere and lower stratosphere (1000-50 mb) that optimize the sample flow rate to increase time response while minimizing loss of precision due to induced turbulence in the sample cell. In-flight and laboratory intercomparisons with existing O3 instruments show that measurement accuracy is maintained in flight.

  14. A calibration method based on virtual large planar target for cameras with large FOV

    NASA Astrophysics Data System (ADS)

    Yu, Lei; Han, Yangyang; Nie, Hong; Ou, Qiaofeng; Xiong, Bangshu

    2018-02-01

    In order to obtain high precision in camera calibration, a target should be large enough to cover the whole field of view (FOV). For cameras with large FOV, using a small target will seriously reduce the precision of calibration. However, using a large target causes many difficulties in making, carrying and employing the large target. In order to solve this problem, a calibration method based on the virtual large planar target (VLPT), which is virtually constructed with multiple small targets (STs), is proposed for cameras with large FOV. In the VLPT-based calibration method, first, the positions and directions of STs are changed several times to obtain a number of calibration images. Secondly, the VLPT of each calibration image is created by finding the virtual point corresponding to the feature points of the STs. Finally, intrinsic and extrinsic parameters of the camera are calculated by using the VLPTs. Experiment results show that the proposed method can not only achieve the similar calibration precision as those employing a large target, but also have good stability in the whole measurement area. Thus, the difficulties to accurately calibrate cameras with large FOV can be perfectly tackled by the proposed method with good operability.

  15. Analysis of the Precision of Pulsar Time Clock Modeltwo

    NASA Astrophysics Data System (ADS)

    Zhao, Cheng-shi; Tong, Ming-lei; Gao, Yu-ping; Yang, Ting-gao

    2018-04-01

    Millisecond pulsars have a very high rotation stability, which can be applied to many research fields, such as the establishment of the pulsar time standard, the detection of gravitational wave, the spacecraft navigation by using X-ray pulsars and so on. In this paper, we employ two millisecond pulsars PSR J0437-4715 and J1713+0743, which are observed by the International Pulsar Timing Array (IPTA), to analyze the precision of pulsar clock parameter and the prediction accuracy of pulse time of arrival (TOA). It is found that the uncertainty of spin frequency is 10-15 Hz, the uncertainty of the first derivative of spin frequency is 10-23 s-2, and the precision of measured rotational parameters increases by one order of magnitude with the accumulated observational data every 4∼5 years. In addition, the errors of TOAs within 4.8 yr which are predicted by the clock model established by the 10 yr data of J0437-4715 are less than 1 μs. Therefore, one can use the pulsar time standard to calibrate the atomic clock, and make the atomic time deviate from the TT (Terrestrial Time) less than 1 μs within 4.8 yr.

  16. 21st century toolkit for optimizing population health through precision nutrition.

    PubMed

    O'Sullivan, Aifric; Henrick, Bethany; Dixon, Bonnie; Barile, Daniela; Zivkovic, Angela; Smilowitz, Jennifer; Lemay, Danielle; Martin, William; German, J Bruce; Schaefer, Sara Elizabeth

    2017-07-05

    Scientific, technological, and economic progress over the last 100 years all but eradicated problems of widespread food shortage and nutrient deficiency in developed nations. But now society is faced with a new set of nutrition problems related to energy imbalance and metabolic disease, which require new kinds of solutions. Recent developments in the area of new analytical tools enable us to systematically study large quantities of detailed and multidimensional metabolic and health data, providing the opportunity to address current nutrition problems through an approach called Precision Nutrition. This approach integrates different kinds of "big data" to expand our understanding of the complexity and diversity of human metabolism in response to diet. With these tools, we can more fully elucidate each individual's unique phenotype, or the current state of health, as determined by the interactions among biology, environment, and behavior. The tools of precision nutrition include genomics, metabolomics, microbiomics, phenotyping, high-throughput analytical chemistry techniques, longitudinal tracking with body sensors, informatics, data science, and sophisticated educational and behavioral interventions. These tools are enabling the development of more personalized and predictive dietary guidance and interventions that have the potential to transform how the public makes food choices and greatly improve population health.

  17. Precision Metabolic Engineering: the Design of Responsive, Selective, and Controllable Metabolic Systems

    PubMed Central

    McNerney, Monica P.; Watstein, Daniel M.; Styczynski, Mark P.

    2015-01-01

    Metabolic engineering is generally focused on static optimization of cells to maximize production of a desired product, though recently dynamic metabolic engineering has explored how metabolic programs can be varied over time to improve titer. However, these are not the only types of applications where metabolic engineering could make a significant impact. Here, we discuss a new conceptual framework, termed “precision metabolic engineering,” involving the design and engineering of systems that make different products in response to different signals. Rather than focusing on maximizing titer, these types of applications typically have three hallmarks: sensing signals that determine the desired metabolic target, completely directing metabolic flux in response to those signals, and producing sharp responses at specific signal thresholds. In this review, we will first discuss and provide examples of precision metabolic engineering. We will then discuss each of these hallmarks and identify which existing metabolic engineering methods can be applied to accomplish those tasks, as well as some of their shortcomings. Ultimately, precise control of metabolic systems has the potential to enable a host of new metabolic engineering and synthetic biology applications for any problem where flexibility of response to an external signal could be useful. PMID:26189665

  18. A precision medicine approach for psychiatric disease based on repeated symptom scores.

    PubMed

    Fojo, Anthony T; Musliner, Katherine L; Zandi, Peter P; Zeger, Scott L

    2017-12-01

    For psychiatric diseases, rich information exists in the serial measurement of mental health symptom scores. We present a precision medicine framework for using the trajectories of multiple symptoms to make personalized predictions about future symptoms and related psychiatric events. Our approach fits a Bayesian hierarchical model that estimates a population-average trajectory for all symptoms and individual deviations from the average trajectory, then fits a second model that uses individual symptom trajectories to estimate the risk of experiencing an event. The fitted models are used to make clinically relevant predictions for new individuals. We demonstrate this approach on data from a study of antipsychotic therapy for schizophrenia, predicting future scores for positive, negative, and general symptoms, and the risk of treatment failure in 522 schizophrenic patients with observations over 8 weeks. While precision medicine has focused largely on genetic and molecular data, the complementary approach we present illustrates that innovative analytic methods for existing data can extend its reach more broadly. The systematic use of repeated measurements of psychiatric symptoms offers the promise of precision medicine in the field of mental health. Copyright © 2017 The Authors. Published by Elsevier Ltd.. All rights reserved.

  19. THE PHOTOMETRIC AND KINEMATIC STRUCTURE OF FACE-ON DISK GALAXIES. III. KINEMATIC INCLINATIONS FROM H{alpha} VELOCITY FIELDS

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Andersen, David R.; Bershady, Matthew A., E-mail: david.andersen@nrc-cnrc.gc.ca, E-mail: mab@astro.wisc.edu

    2013-05-01

    Using the integral field unit DensePak on the WIYN 3.5 m telescope we have obtained H{alpha} velocity fields of 39 nearly face-on disks at echelle resolutions. High-quality, uniform kinematic data and a new modeling technique enabled us to derive accurate and precise kinematic inclinations with mean i{sub kin} = 23 Degree-Sign for 90% of these galaxies. Modeling the kinematic data as single, inclined disks in circular rotation improves upon the traditional tilted-ring method. We measure kinematic inclinations with a precision in sin i of 25% at 20 Degree-Sign and 6% at 30 Degree-Sign . Kinematic inclinations are consistent with photometricmore » and inverse Tully-Fisher inclinations when the sample is culled of galaxies with kinematic asymmetries, for which we give two specific prescriptions. Kinematic inclinations can therefore be used in statistical ''face-on'' Tully-Fisher studies. A weighted combination of multiple, independent inclination measurements yield the most precise and accurate inclination. Combining inverse Tully-Fisher inclinations with kinematic inclinations yields joint probability inclinations with a precision in sin i of 10% at 15 Degree-Sign and 5% at 30 Degree-Sign . This level of precision makes accurate mass decompositions of galaxies possible even at low inclination. We find scaling relations between rotation speed and disk-scale length identical to results from more inclined samples. We also observe the trend of more steeply rising rotation curves with increased rotation speed and light concentration. This trend appears to be uncorrelated with disk surface brightness.« less

  20. Human Microbiome and Learning Healthcare Systems: Integrating Research and Precision Medicine for Inflammatory Bowel Disease

    PubMed Central

    Chuong, Kim H.; Mack, David R.; Stintzi, Alain

    2018-01-01

    Abstract Healthcare institutions face widespread challenges of delivering high-quality and cost-effective care, while keeping up with rapid advances in biomedical knowledge and technologies. Moreover, there is increased emphasis on developing personalized or precision medicine targeted to individuals or groups of patients who share a certain biomarker signature. Learning healthcare systems (LHS) have been proposed for integration of research and clinical practice to fill major knowledge gaps, improve care, reduce healthcare costs, and provide precision care. To date, much discussion in this context has focused on the potential of human genomic data, and not yet on human microbiome data. Rapid advances in human microbiome research suggest that profiling of, and interventions on, the human microbiome can provide substantial opportunity for improved diagnosis, therapeutics, risk management, and risk stratification. In this study, we discuss a potential role for microbiome science in LHSs. We first review the key elements of LHSs, and discuss possibilities of Big Data and patient engagement. We then consider potentials and challenges of integrating human microbiome research into clinical practice as part of an LHS. With rapid growth in human microbiome research, patient-specific microbial data will begin to contribute in important ways to precision medicine. Hence, we discuss how patient-specific microbial data can help guide therapeutic decisions and identify novel effective approaches for precision care of inflammatory bowel disease. To the best of our knowledge, this expert analysis makes an original contribution with new insights poised at the emerging intersection of LHSs, microbiome science, and postgenomics medicine. PMID:28282257

  1. Fidelity of the representation of value in decision-making

    PubMed Central

    Dowding, Ben A.

    2017-01-01

    The ability to make optimal decisions depends on evaluating the expected rewards associated with different potential actions. This process is critically dependent on the fidelity with which reward value information can be maintained in the nervous system. Here we directly probe the fidelity of value representation following a standard reinforcement learning task. The results demonstrate a previously-unrecognized bias in the representation of value: extreme reward values, both low and high, are stored significantly more accurately and precisely than intermediate rewards. The symmetry between low and high rewards pertained despite substantially higher frequency of exposure to high rewards, resulting from preferential exploitation of more rewarding options. The observed variation in fidelity of value representation retrospectively predicted performance on the reinforcement learning task, demonstrating that the bias in representation has an impact on decision-making. A second experiment in which one or other extreme-valued option was omitted from the learning sequence showed that representational fidelity is primarily determined by the relative position of an encoded value on the scale of rewards experienced during learning. Both variability and guessing decreased with the reduction in the number of options, consistent with allocation of a limited representational resource. These findings have implications for existing models of reward-based learning, which typically assume defectless representation of reward value. PMID:28248958

  2. A canonical theory of dynamic decision-making.

    PubMed

    Fox, John; Cooper, Richard P; Glasspool, David W

    2013-01-01

    Decision-making behavior is studied in many very different fields, from medicine and economics to psychology and neuroscience, with major contributions from mathematics and statistics, computer science, AI, and other technical disciplines. However the conceptualization of what decision-making is and methods for studying it vary greatly and this has resulted in fragmentation of the field. A theory that can accommodate various perspectives may facilitate interdisciplinary working. We present such a theory in which decision-making is articulated as a set of canonical functions that are sufficiently general to accommodate diverse viewpoints, yet sufficiently precise that they can be instantiated in different ways for specific theoretical or practical purposes. The canons cover the whole decision cycle, from the framing of a decision based on the goals, beliefs, and background knowledge of the decision-maker to the formulation of decision options, establishing preferences over them, and making commitments. Commitments can lead to the initiation of new decisions and any step in the cycle can incorporate reasoning about previous decisions and the rationales for them, and lead to revising or abandoning existing commitments. The theory situates decision-making with respect to other high-level cognitive capabilities like problem solving, planning, and collaborative decision-making. The canonical approach is assessed in three domains: cognitive and neuropsychology, artificial intelligence, and decision engineering.

  3. A Canonical Theory of Dynamic Decision-Making

    PubMed Central

    Fox, John; Cooper, Richard P.; Glasspool, David W.

    2012-01-01

    Decision-making behavior is studied in many very different fields, from medicine and economics to psychology and neuroscience, with major contributions from mathematics and statistics, computer science, AI, and other technical disciplines. However the conceptualization of what decision-making is and methods for studying it vary greatly and this has resulted in fragmentation of the field. A theory that can accommodate various perspectives may facilitate interdisciplinary working. We present such a theory in which decision-making is articulated as a set of canonical functions that are sufficiently general to accommodate diverse viewpoints, yet sufficiently precise that they can be instantiated in different ways for specific theoretical or practical purposes. The canons cover the whole decision cycle, from the framing of a decision based on the goals, beliefs, and background knowledge of the decision-maker to the formulation of decision options, establishing preferences over them, and making commitments. Commitments can lead to the initiation of new decisions and any step in the cycle can incorporate reasoning about previous decisions and the rationales for them, and lead to revising or abandoning existing commitments. The theory situates decision-making with respect to other high-level cognitive capabilities like problem solving, planning, and collaborative decision-making. The canonical approach is assessed in three domains: cognitive and neuropsychology, artificial intelligence, and decision engineering. PMID:23565100

  4. Research on the tool holder mode in high speed machining

    NASA Astrophysics Data System (ADS)

    Zhenyu, Zhao; Yongquan, Zhou; Houming, Zhou; Xiaomei, Xu; Haibin, Xiao

    2018-03-01

    High speed machining technology can improve the processing efficiency and precision, but also reduce the processing cost. Therefore, the technology is widely regarded in the industry. With the extensive application of high-speed machining technology, high-speed tool system has higher and higher requirements on the tool chuck. At present, in high speed precision machining, several new kinds of clip heads are as long as there are heat shrinkage tool-holder, high-precision spring chuck, hydraulic tool-holder, and the three-rib deformation chuck. Among them, the heat shrinkage tool-holder has the advantages of high precision, high clamping force, high bending rigidity and dynamic balance, etc., which are widely used. Therefore, it is of great significance to research the new requirements of the machining tool system. In order to adapt to the requirement of high speed machining precision machining technology, this paper expounds the common tool holder technology of high precision machining, and proposes how to select correctly tool clamping system in practice. The characteristics and existing problems are analyzed in the tool clamping system.

  5. High-accuracy measurements of N2O concentration and site-specific nitrogen isotopes in small or high concentration samples

    NASA Astrophysics Data System (ADS)

    Palmer, M. R.; Arata, C.; Huang, K.

    2014-12-01

    Nitrous oxide (N2O) gas is among the major contributors to global warming and ozone depletion in stratosphere. Quantitative estimate of N­2O production in various pathways and N­2O fluxes across different reservoirs is the key to understanding the role of N­2O in the global change. To achieve this goal, accurate and concurrent measurement of both N2O concentration ([N2O]) and its site-specific isotopic composition (SP-δ15N), namely δ15Nα and δ15Nβ, is desired. Recent developments in Cavity Ring-Down Spectroscopy (CRDS) have enabled high precision measurements of [N2O] and SP-δ15N of a continuous gas flow. However, many N­­2O samples are discrete with limited volume (< 500 ml), and/or high [N2O] (> 2 ppm), and are not suitable for direct measurements by CRDS. Here we present results of a Small Sample Isotope Module 2 (SSIM2) which is coupled to and automatically coordinated with a Picarro isotopic N2O CRDS analyzer to handle and measure high concentration and/or small volume samples. The SSIM2 requires 20 ml of sample per analysis, and transfers the sample to the CRDS for high precision measurement. When the sample injection is < 20 ml, a zero gas is optionally filled to make up the volume. We used the SSIM2 to dilute high [N2O] samples and < 20 ml samples, and tested the effect of dilution on the measured SP-δ15N. In addition, we employed and tested a newly developed double injection method for samples adequate for two 20 ml injections. After the SSIM2 and the CRDS cavity was primed with the first injection, the second injection, which has negligible dilution of the sample, can be accurately measured for both [N2O] and SP-δ15N. Results of these experiments indicate that the precision of SSIM2-CRDS is similar to that of the continuous measurements using the CRDS alone, and that dilution has minimal effect on SP-δ15N, as along as the [N2O] is > 300 ppb after dilution. Overall, the precision of SP-δ15N measured using the SSIM2 is < 0.5 ‰.

  6. High-Accuracy Comparison Between the Post-Newtonian and Self-Force Dynamics of Black-Hole Binaries

    NASA Astrophysics Data System (ADS)

    Blanchet, Luc; Detweiler, Steven; Le Tiec, Alexandre; Whiting, Bernard F.

    The relativistic motion of a compact binary system moving in circular orbit is investigated using the post-Newtonian (PN) approximation and the perturbative self-force (SF) formalism. A particular gauge-invariant observable quantity is computed as a function of the binary's orbital frequency. The conservative effect induced by the gravitational SF is obtained numerically with high precision, and compared to the PN prediction developed to high order. The PN calculation involves the computation of the 3PN regularized metric at the location of the particle. Its divergent self-field is regularized by means of dimensional regularization. The poles ∝ {(d - 3)}^{-1} that occur within dimensional regularization at the 3PN order disappear from the final gauge-invariant result. The leading 4PN and next-to-leading 5PN conservative logarithmic contributions originating from gravitational wave tails are also obtained. Making use of these exact PN results, some previously unknown PN coefficients are measured up to the very high 7PN order by fitting to the numerical SF data. Using just the 2PN and new logarithmic terms, the value of the 3PN coefficient is also confirmed numerically with very high precision. The consistency of this cross-cultural comparison provides a crucial test of the very different regularization methods used in both SF and PN formalisms, and illustrates the complementarity of these approximation schemes when modeling compact binary systems.

  7. Conditioning of BPM pickup signals for operations of the Duke storage ring with a wide range of single-bunch current

    NASA Astrophysics Data System (ADS)

    Xu, Wei; Li, Jing-Yi; Huang, Sen-Lin; Z. Wu, W.; Hao, H.; P., Wang; K. Wu, Y.

    2014-10-01

    The Duke storage ring is a dedicated driver for the storage ring based oscillator free-electron lasers (FELs), and the High Intensity Gamma-ray Source (HIGS). It is operated with a beam current ranging from about 1 mA to 100 mA per bunch for various operations and accelerator physics studies. High performance operations of the FEL and γ-ray source require a stable electron beam orbit, which has been realized by the global orbit feedback system. As a critical part of the orbit feedback system, the electron beam position monitors (BPMs) are required to be able to precisely measure the electron beam orbit in a wide range of the single-bunch current. However, the high peak voltage of the BPM pickups associated with high single-bunch current degrades the performance of the BPM electronics, and can potentially damage the BPM electronics. A signal conditioning method using low pass filters is developed to reduce the peak voltage to protect the BPM electronics, and to make the BPMs capable of working with a wide range of single-bunch current. Simulations and electron beam based tests are performed. The results show that the Duke storage ring BPM system is capable of providing precise orbit measurements to ensure highly stable FEL and HIGS operations.

  8. Precision medicine for cancer with next-generation functional diagnostics.

    PubMed

    Friedman, Adam A; Letai, Anthony; Fisher, David E; Flaherty, Keith T

    2015-12-01

    Precision medicine is about matching the right drugs to the right patients. Although this approach is technology agnostic, in cancer there is a tendency to make precision medicine synonymous with genomics. However, genome-based cancer therapeutic matching is limited by incomplete biological understanding of the relationship between phenotype and cancer genotype. This limitation can be addressed by functional testing of live patient tumour cells exposed to potential therapies. Recently, several 'next-generation' functional diagnostic technologies have been reported, including novel methods for tumour manipulation, molecularly precise assays of tumour responses and device-based in situ approaches; these address the limitations of the older generation of chemosensitivity tests. The promise of these new technologies suggests a future diagnostic strategy that integrates functional testing with next-generation sequencing and immunoprofiling to precisely match combination therapies to individual cancer patients.

  9. Study of the precision guided communication of digital television

    NASA Astrophysics Data System (ADS)

    Liu, Lun

    2012-04-01

    Along with the progress and development of the digital technology, there produced the transmission of the new media by medium of such as the network, mobile phones and the digital television, while among them digital TV has the superiority of other media. The appearance and development of digital TV will induce a profound change in the broadcasting and television industry chain. This paper started with discussing the transformation of digital television in profit model, mode of operation and mode of transmission to construct the precision-guided communication theory; And then analyzes the properties and marketing nature of the precision-guided communication to make the construction of the precision-guided communication marketing mode; And put forward the implementing of the precision-guided communication marketing strategies and concrete steps; At the end of the article the author summarized four conclusions.

  10. Solid state neutron dosimeter for space applications

    NASA Technical Reports Server (NTRS)

    Entine, Gerald; Nagargar, Vivek; Sharif, Daud

    1990-01-01

    Personnel engaged in space flight are exposed to significant flux of high energy neutrons arising from both primary and secondary sources of ionizing radiation. Presently, there exist no compact neutron sensor capable of being integrated in a flight instrument to provide real time measurement of this radiation flux. A proposal was made to construct such an instrument using special PIN silicon diode which has the property of being insensitive to the other forms of ionizing radiation. Studies were performed to determine the design and construction of a better reading system to allow the PIN diode to be read with high precision. The physics of the device was studied, especially with respect to those factors which affect the sensitivity and reproducibility of the neutron response. This information was then used to develop methods to achieve high sensitivity at low neutron doses. The feasibility was shown of enhancing the PIN diode sensitivity to make possible the measurement of the low doses of neutrons encountered in space flights. The new PIN diode will make possible the development of a very compact, accurate, personal neutron dosimeter.

  11. Enumerative and binomial sequential sampling plans for the multicolored Asian lady beetle (Coleoptera: Coccinellidae) in wine grapes.

    PubMed

    Galvan, T L; Burkness, E C; Hutchison, W D

    2007-06-01

    To develop a practical integrated pest management (IPM) system for the multicolored Asian lady beetle, Harmonia axyridis (Pallas) (Coleoptera: Coccinellidae), in wine grapes, we assessed the spatial distribution of H. axyridis and developed eight sampling plans to estimate adult density or infestation level in grape clusters. We used 49 data sets collected from commercial vineyards in 2004 and 2005, in Minnesota and Wisconsin. Enumerative plans were developed using two precision levels (0.10 and 0.25); the six binomial plans reflected six unique action thresholds (3, 7, 12, 18, 22, and 31% of cluster samples infested with at least one H. axyridis). The spatial distribution of H. axyridis in wine grapes was aggregated, independent of cultivar and year, but it was more randomly distributed as mean density declined. The average sample number (ASN) for each sampling plan was determined using resampling software. For research purposes, an enumerative plan with a precision level of 0.10 (SE/X) resulted in a mean ASN of 546 clusters. For IPM applications, the enumerative plan with a precision level of 0.25 resulted in a mean ASN of 180 clusters. In contrast, the binomial plans resulted in much lower ASNs and provided high probabilities of arriving at correct "treat or no-treat" decisions, making these plans more efficient for IPM applications. For a tally threshold of one adult per cluster, the operating characteristic curves for the six action thresholds provided binomial sequential sampling plans with mean ASNs of only 19-26 clusters, and probabilities of making correct decisions between 83 and 96%. The benefits of the binomial sampling plans are discussed within the context of improving IPM programs for wine grapes.

  12. Highly enhanced ultraviolet photosensitivity and recovery speed in electrospun Ni-doped SnO2 nanobelts

    NASA Astrophysics Data System (ADS)

    Huang, Siya; Matsubara, Kohei; Cheng, Jing; Li, Heping; Pan, Wei

    2013-09-01

    Precisely controlled Ni-doped SnO2 (NSO) nanobelt arrays are synthesized and assembled via electrospinning. In comparison to pristine SnO2 nanobelts, enhanced photosensitivity (˜103) as well as recovery speed (˜1 s) is obtained in NSO nanobelts. The mechanism is clarified by the compensation effect of acceptor impurity Ni, which not only promotes the oxygen-surface interaction but also introduces trapping centers in SnO2 matrix. The reduced grain size (˜4 nm) along with increased depletion layer thickness also benefits the photosensitivity of NSO nanobelts. These improved photoresponse properties make the NSO nanobelt a promising candidate for high-performance ultraviolet detectors.

  13. Study on Surface Roughness of Modified Silicon Carbide Mirrors polished by Magnetorheological Finishing

    NASA Astrophysics Data System (ADS)

    Du, Hang; Song, Ci; Li, Shengyi

    2018-01-01

    In order to obtain high precision and high surface quality silicon carbide mirrors, the silicon carbide mirror substrate is subjected to surface modification treatment. In this paper, the problem of Silicon Carbide (SiC) mirror surface roughness deterioration by MRF is studied. The reasons of surface flaws of “Comet tail” are analyzed. Influence principle of MRF polishing depth and the surface roughness of modified SiC mirrors is obtained by experiments. On this basis, the united process of modified SiC mirrors is proposed which is combined MRF with the small grinding head CCOS. The united process makes improvement in the surface accuracy and surface roughness of modified SiC mirrors.

  14. Digital Processing Of Young's Fringes In Speckle Photography

    NASA Astrophysics Data System (ADS)

    Chen, D. J.; Chiang, F. P.

    1989-01-01

    A new technique for fully automatic diffraction fringe measurement in point-wise speckle photograph analysis is presented in this paper. The fringe orientation and spacing are initially estimated with the help of 1-D FFT. A 2-D convolution filter is then applied to enhance the estimated image . High signal-to-noise rate (SNR) fringe pattern is achieved which makes it feasible for precise determination of the displacement components. The halo-effect is also optimally eliminated in a new way. With the computation time compared favorably with those of 2-D autocorrelation method and the iterative 2-D FFT method. High reliability and accurate determination of displacement components are achieved over a wide range of fringe density.

  15. AATSR: global-change and surface-temperature measurements from Envisat

    NASA Astrophysics Data System (ADS)

    Llewellyn-Jones, D.; Edwards, M. C.; Mutlow, C. T.; Birks, A. R.; Barton, I. J.; Tait, H.

    2001-02-01

    The Advanced Along-Track Scanning Radiometer (AATSR) onboard ESA's Envisat spacecraft is designed to meet the challenging task of monitoring and detecting climate change. It builds on the success of its predecessor instruments on the ERS-1 and ERS-2 satellites, and will lead to a 15+ year record of precise and accurate global Sea-Surface Temperature (SST) measurements, thereby making a valuable contribution to the long-term climate record. With its high-accuracy, high-quality imagery and channels in the visible, near-infrared and thermal wavelengths, AATSR data will support many applications in addition to oceanographic and climate research, including a wide range of land-surface, cryosphere and atmospheric studies.

  16. Capture Cross-section Measurement of 241Am(n,γ) at J-PARC/MLF/ANNRI

    NASA Astrophysics Data System (ADS)

    Harada, H.; Ohta, M.; Kimura, A.; Furutaka, K.; Hirose, K.; Hara, K. Y.; Kin, T.; Kitatani, F.; Koizumi, M.; Nakamura, S.; Oshima, M.; Toh, Y.; Igashira, M.; Katabuchi, T.; Mizumoto, M.; Kino, K.; Kiyanagi, Y.; Fujii, T.; Fukutani, S.; Hori, J.; Takamiya, K.

    2014-05-01

    The 241Am(n, γ) 242Am cross sections have been measured for neutron energies between 0.01 and 10 eV using the Accurate Neutron-Nucleus Reaction measurement Instrument (ANNRI) installed at the Materials and Life-science experimental Facility (MLF) in J-PARC. ANNRI combines the strongest neutron-pulsed beam and a high energy resolution γ-ray spectrometer, making possible accurate measurements of neutron capture cross sections for highly radioactive samples. From the measured cross section, the Westcott neutron capture factor and strength of the first three resonances in 241Am are deduced. These results with precision less than 0.5 % are compared with those derived from JENDL-4.0.

  17. Satellite image processing for precision agriculture and agroindustry using convolutional neural network and genetic algorithm

    NASA Astrophysics Data System (ADS)

    Firdaus; Arkeman, Y.; Buono, A.; Hermadi, I.

    2017-01-01

    Translating satellite imagery to a useful data for decision making during this time are usually done manually by human. In this research, we are going to translate satellite imagery by using artificial intelligence method specifically using convolutional neural network and genetic algorithm to become a useful data for decision making, especially for precision agriculture and agroindustry. In this research, we are focused on how to made a sustainable land use planning with 3 objectives. The first is maximizing economic factor. Second is minimizing CO2 emission and the last is minimizing land degradation. Results show that by using artificial intelligence method, can produced a good pareto optimum solutions in a short time.

  18. On acquiring decision making skills for endovascular interventions.

    PubMed

    Lanzer, Peter; Prechelt, Lutz

    2008-11-01

    To improve interventional training we propose a staged rational approach for decision making and skill acquisition. Education and training for endovascular interventions should start to develop the learners' decision-making skills by learning from explicit representations of master interventionist's tacit decision-making knowledge through implementation of the notions of generic interventional modules, interventional strategic and tactical designs. We hope that these suggestions will encourage action, stimulate dialogue and advance the precision of our learning, procedures, practice and patient care.

  19. Spatiotemporal dynamics of random stimuli account for trial-to-trial variability in perceptual decision making

    PubMed Central

    Park, Hame; Lueckmann, Jan-Matthis; von Kriegstein, Katharina; Bitzer, Sebastian; Kiebel, Stefan J.

    2016-01-01

    Decisions in everyday life are prone to error. Standard models typically assume that errors during perceptual decisions are due to noise. However, it is unclear how noise in the sensory input affects the decision. Here we show that there are experimental tasks for which one can analyse the exact spatio-temporal details of a dynamic sensory noise and better understand variability in human perceptual decisions. Using a new experimental visual tracking task and a novel Bayesian decision making model, we found that the spatio-temporal noise fluctuations in the input of single trials explain a significant part of the observed responses. Our results show that modelling the precise internal representations of human participants helps predict when perceptual decisions go wrong. Furthermore, by modelling precisely the stimuli at the single-trial level, we were able to identify the underlying mechanism of perceptual decision making in more detail than standard models. PMID:26752272

  20. Julius Edgar Lilienfeld Prize Talk: Measuring the Electron Magnetic Moment and the Fine Structure Constant

    NASA Astrophysics Data System (ADS)

    Gabrielse, Gerald

    2011-05-01

    The electron magnetic moment in Bohr magnetons has been measured to a precision of 3 parts in 1013. This measurement, with quantum electrodynamics (AED) theory, provides the most precise value of the fine structure constant. This measurement, with a value of the fine structure from other measurements, also tests QED and sets a limit on the internal structure of the electron. A one-electron quantum cyclotron is at the heart of the measurement -- an electron suspended in a magnetic field and cooled enough that its lowest cyclotron and spin quantum states can be deduced with quantum nondemolition (QND) measurements. A cylindrical Penning trap cavity inhibits spontaneous emission and feedback methods make the electron excite and sustain its own motion for detection. A new apparatus is being commissioned in pursuit of more precise measurements. Adapted methods are promising for observing a proton spin flip, which should make it possible to compare the antiproton and proton magnetic moments a million times more accurately than is currently possible.

  1. Precision in Addiction Care: Does It Make a Difference?

    PubMed Central

    van der Stel, Jaap

    2015-01-01

    This perspective article explores the possibilities of precision in addiction care — even better individually fitted or tailor-made care — and examines what changes we need to make in order to realize sensible progress in epidemiological key figures. The first part gives a short review on the development of addiction care and tries to answer the question of where we stand now and what has been achieved in addiction science through the development and evaluation of interventions in the past decades. Following this analysis, attention will be paid to what lies ahead. This second part focuses on the question of how addiction care can deal with the consequences of the emerging paradigm of personalized or precision medicine, which is based on the fundamental assumption that individual differences matter. Finally, some limitations and conditions as well as tasks and goals for progress are raised. In conclusion, it is argued that integration of addiction care in (mental) health care in the future is desirable. PMID:26604867

  2. In-airway molecular flow sensing: A new technology for continuous, noninvasive monitoring of oxygen consumption in critical care.

    PubMed

    Ciaffoni, Luca; O'Neill, David P; Couper, John H; Ritchie, Grant A D; Hancock, Gus; Robbins, Peter A

    2016-08-01

    There are no satisfactory methods for monitoring oxygen consumption in critical care. To address this, we adapted laser absorption spectroscopy to provide measurements of O2, CO2, and water vapor within the airway every 10 ms. The analyzer is integrated within a novel respiratory flow meter that is an order of magnitude more precise than other flow meters. Such precision, coupled with the accurate alignment of gas concentrations with respiratory flow, makes possible the determination of O2 consumption by direct integration over time of the product of O2 concentration and flow. The precision is illustrated by integrating the balance gas (N2 plus Ar) flow and showing that this exchange was near zero. Measured O2 consumption changed by <5% between air and O2 breathing. Clinical capability was illustrated by recording O2 consumption during an aortic aneurysm repair. This device now makes easy, accurate, and noninvasive measurement of O2 consumption for intubated patients in critical care possible.

  3. In-airway molecular flow sensing: A new technology for continuous, noninvasive monitoring of oxygen consumption in critical care

    PubMed Central

    Ciaffoni, Luca; O’Neill, David P.; Couper, John H.; Ritchie, Grant A. D.; Hancock, Gus; Robbins, Peter A.

    2016-01-01

    There are no satisfactory methods for monitoring oxygen consumption in critical care. To address this, we adapted laser absorption spectroscopy to provide measurements of O2, CO2, and water vapor within the airway every 10 ms. The analyzer is integrated within a novel respiratory flow meter that is an order of magnitude more precise than other flow meters. Such precision, coupled with the accurate alignment of gas concentrations with respiratory flow, makes possible the determination of O2 consumption by direct integration over time of the product of O2 concentration and flow. The precision is illustrated by integrating the balance gas (N2 plus Ar) flow and showing that this exchange was near zero. Measured O2 consumption changed by <5% between air and O2 breathing. Clinical capability was illustrated by recording O2 consumption during an aortic aneurysm repair. This device now makes easy, accurate, and noninvasive measurement of O2 consumption for intubated patients in critical care possible. PMID:27532048

  4. Robust Decision Making in a Nonlinear World

    ERIC Educational Resources Information Center

    Dougherty, Michael R.; Thomas, Rick P.

    2012-01-01

    The authors propose a general modeling framework called the general monotone model (GeMM), which allows one to model psychological phenomena that manifest as nonlinear relations in behavior data without the need for making (overly) precise assumptions about functional form. Using both simulated and real data, the authors illustrate that GeMM…

  5. Solving Ordinary Differential Equations

    NASA Technical Reports Server (NTRS)

    Krogh, F. T.

    1987-01-01

    Initial-value ordinary differential equation solution via variable order Adams method (SIVA/DIVA) package is collection of subroutines for solution of nonstiff ordinary differential equations. There are versions for single-precision and double-precision arithmetic. Requires fewer evaluations of derivatives than other variable-order Adams predictor/ corrector methods. Option for direct integration of second-order equations makes integration of trajectory problems significantly more efficient. Written in FORTRAN 77.

  6. Strategy and Airpower

    DTIC Science & Technology

    2011-01-01

    myopia often leads otherwise competent observers to under­ estimate significantly the new technology’s potential. Two business examples stand out: in...direction. With precision of effect combined with precision of impact, bloodless war becomes a reality . To this point, we have tried to make the...against virtually all of the centers of gravity directly related to strategic objectives, regardless of their loca­ tion. Because it can bring many

  7. Universal, computer facilitated, steady state oscillator, closed loop analysis theory and some applications to precision oscillators

    NASA Technical Reports Server (NTRS)

    Parzen, Benjamin

    1992-01-01

    The theory of oscillator analysis in the immittance domain should be read in conjunction with the additional theory presented here. The combined theory enables the computer simulation of the steady state oscillator. The simulation makes the calculation of the oscillator total steady state performance practical, including noise at all oscillator locations. Some specific precision oscillators are analyzed.

  8. Quality assessment of decision-making in colorectal cancer multidisciplinary meetings.

    PubMed

    Seretis, Charalampos; Mankotia, Rajnish; Goonetilleke, Kolitha; Rawstorne, Edward

    2014-01-01

    The quality of decision-making in the colorectal multidisciplinary team (MDT) meetings can significantly affect the quality of care delivered to patients with colorectal cancer. We performed a prospective study to assess the quality of the MDT meetings in a specialized colorectal unit using an externally observational validated tool. An externally validated observational tool, the Colorectal Multidisciplinary Team Metric for Observation of Decision-Making (cMDT-MODe), was used to assess the quality of clinical decision-making in 64 cases. Although case history information presented by the responsible surgeon was rated high (4.4/5), the quality of radiological and histopathological information regarding each patient's case which was available at the time was less adequate, scoring 3.9/5 and 3.8/5, respectively. Moreover, the precise knowledge of patients' personal views and circumstances was a field requiring further improvement. In a general overview however, the quality and extent of the available information enabled the MDT to provide a clear recommendation regarding the patients' treatment plans in 87.5% of the cases. The cMDT-MODe tool can be used to prospectively audit the quality of clinical decision-making in the colorectal MDT meetings and highlight the fields of potential improvement.

  9. Resonant scattering as a sensitive diagnostic of current collisional plasma models

    NASA Astrophysics Data System (ADS)

    Ogorzalek, Anna; Zhuravleva, Irina; Allen, Steven W.; Pinto, Ciro; Werner, Norbert; Mantz, Adam; Canning, Rebecca; Fabian, Andrew C.; Kaastra, Jelle S.; de Plaa, Jelle

    2017-08-01

    Resonant scattering is a subtle process that suppresses fluxes of some of the brightest optically thick X-ray emission lines produced by collisional plasmas in galaxy clusters and massive early-type galaxies. The amplitude of the effect depends on the turbulent structure of the hot gas, making it a sensitive velocity probe. It is therefore crucial to properly model this effect in order to correctly interpret high resolution X-ray spectra. Our measurements of resonant scattering with XMM-Newton Reflection Grating Spectrometer in giant elliptical galaxies and with Hitomi in the center of Perseus Cluster show that the potentially rich inference from this effect is limited by the uncertainties in the atomic data underlying plasma codes such as APEC and SPEX. Typically, the effect is of the order of 10-20%, while the discrepancy between the two codes is of similar order or even higher. Precise knowledge of the emissivity and oscillator strengths of lines emitted by Fe XVII and Fe XXV, as well as their respective uncertainties propagated through plasma codes are key to understanding gas dynamics and microphysics in giant galaxies and cluster ICM, respectively. This is especially crucial for massive ellipticals, where sub-eV resolution would be needed to measure line broadening precisely, making resonant scattering an important velocity diagnostic in these systems for the foreseeable future. In this poster, I will summarize current status of resonant scattering measurements and show how they depend on the assumed atomic data. I will also discuss which improvements are essential to maximize scientific inference from future high resolution X-ray spectra.

  10. A precision mechanical nerve stimulator

    NASA Technical Reports Server (NTRS)

    Tcheng, Ping; Supplee, Frank H., Jr.; Prass, Richard L.

    1988-01-01

    An electromechanical device, used to apply and monitor stimulating pulses to a mammalian motor nerve, has been successfully developed at NASA Langley Research Center. Two existing force transducers, a flight skin friction balance and a miniature skin friction balance which were designed for making aerodynamic drag measurements, were modified and incorporated to form this precision instrument. The nerve stimulator is a type one servomechanism capable of applying and monitoring stimulating pulses of 0 to 10 grams with a precision of better than +/- 0.05 grams. Additionally, the device can be independently used to apply stimulating pulses by displacing the nerve from 0 to 0.25 mm with a precision of better than +/- 0.001 mm while measuring the level of the load applied.

  11. Error analysis of high-rate GNSS precise point positioning for seismic wave measurement

    NASA Astrophysics Data System (ADS)

    Shu, Yuanming; Shi, Yun; Xu, Peiliang; Niu, Xiaoji; Liu, Jingnan

    2017-06-01

    High-rate GNSS precise point positioning (PPP) has been playing a more and more important role in providing precise positioning information in fast time-varying environments. Although kinematic PPP is commonly known to have a precision of a few centimeters, the precision of high-rate PPP within a short period of time has been reported recently with experiments to reach a few millimeters in the horizontal components and sub-centimeters in the vertical component to measure seismic motion, which is several times better than the conventional kinematic PPP practice. To fully understand the mechanism of mystified excellent performance of high-rate PPP within a short period of time, we have carried out a theoretical error analysis of PPP and conducted the corresponding simulations within a short period of time. The theoretical analysis has clearly indicated that the high-rate PPP errors consist of two types: the residual systematic errors at the starting epoch, which affect high-rate PPP through the change of satellite geometry, and the time-varying systematic errors between the starting epoch and the current epoch. Both the theoretical error analysis and simulated results are fully consistent with and thus have unambiguously confirmed the reported high precision of high-rate PPP, which has been further affirmed here by the real data experiments, indicating that high-rate PPP can indeed achieve the millimeter level of precision in the horizontal components and the sub-centimeter level of precision in the vertical component to measure motion within a short period of time. The simulation results have clearly shown that the random noise of carrier phases and higher order ionospheric errors are two major factors to affect the precision of high-rate PPP within a short period of time. The experiments with real data have also indicated that the precision of PPP solutions can degrade to the cm level in both the horizontal and vertical components, if the geometry of satellites is rather poor with a large DOP value.

  12. A new energy-efficient control approach for astronomical telescope drive system

    NASA Astrophysics Data System (ADS)

    Zhou, W.; Wang, Y.

    2012-12-01

    Drive control makes the astronomical telescope accurately tracking celestial bodies in spite of external and internal disturbances, which is a key technique to the performance of telescopes. In this paper, we propose a nonlinear ad, aptive observer based on power reversible approach for high precision telescope position tracking. The nonlinear adaptive observer automatically estimates the disturbances in drive system, and the observed value is applied to compensate for the real disturbances. With greatly reduced disturbances, the control precision can be evidently improved. In conventional drive control, the brake device is often used to slow down the reaction wheel and may waste enormous energy. To avoid those disadvantages, an H-bridge is put forward for wheel speed regulation. Such H-bridge has four independent sections, and each section mainly consists of a power electronic switch and an anti-parallel diode. During the period of the mount slowing down, the armature current of drive motor goes through the two path-wise diodes to charge the battery. Thus, energy waste is avoided. Based on the disturbance compensation, an optimal controller is designed to minimize an evaluation function which is made up of a weighted sum of position errors and energy consumption.The outputs of the controller are applied to control the H-bridge. Simulations are performed in MATLAB language. The results show that high precision control can be obtained by the proposed approach. And the energy consumption will be remarkably reduced.

  13. The characterization and application of a low resource FPGA-based time to digital converter

    NASA Astrophysics Data System (ADS)

    Balla, Alessandro; Mario Beretta, Matteo; Ciambrone, Paolo; Gatta, Maurizio; Gonnella, Francesco; Iafolla, Lorenzo; Mascolo, Matteo; Messi, Roberto; Moricciani, Dario; Riondino, Domenico

    2014-03-01

    Time to Digital Converters (TDCs) are very common devices in particles physics experiments. A lot of "off-the-shelf" TDCs can be employed but the necessity of a custom DAta acQuisition (DAQ) system makes the TDCs implemented on the Field-Programmable Gate Arrays (FPGAs) desirable. Most of the architectures developed so far are based on the tapped delay lines with precision down to 10 ps, obtained with high FPGA resources usage and non-linearity issues to be managed. Often such precision is not necessary; in this case TDC architectures with low resources occupancy are preferable allowing the implementation of data processing systems and of other utilities on the same device. In order to reconstruct γγ physics events tagged with High Energy Tagger (HET) in the KLOE-2 (K LOng Experiment 2), we need to measure the Time Of Flight (TOF) of the electrons and positrons from the KLOE-2 Interaction Point (IP) to our tagging stations (11 m apart). The required resolution must be better than the bunch spacing (2.7 ns). We have developed and implemented on a Xilinx Virtex-5 FPGA a 32 channel TDC with a precision of 255 ps and low non-linearity effects along with an embedded data acquisition system and the interface to the online FARM of KLOE-2. The TDC is based on a low resources occupancy technique: the 4×Oversampling technique which, in this work, is pushed to its best resolution and its performances were exhaustively measured.

  14. Evaluation of laser diode thermal desorption-tandem mass spectrometry (LDTD-MS-MS) in forensic toxicology.

    PubMed

    Bynum, Nichole D; Moore, Katherine N; Grabenauer, Megan

    2014-10-01

    Many forensic laboratories experience backlogs due to increased drug-related cases. Laser diode thermal desorption (LDTD) has demonstrated its applicability in other scientific areas by providing data comparable with instrumentation, such as liquid chromatography-tandem mass spectrometry, in less time. LDTD-MS-MS was used to validate 48 compounds in drug-free human urine and blood for screening or quantitative analysis. Carryover, interference, limit of detection, limit of quantitation, matrix effect, linearity, precision and accuracy and stability were evaluated. Quantitative analysis indicated that LDTD-MS-MS produced precise and accurate results with the average overall within-run precision in urine and blood represented by a %CV <14.0 and <7.0, respectively. The accuracy for all drugs in urine ranged from 88.9 to 104.5% and 91.9 to 107.1% in blood. Overall, LDTD has the potential for use in forensic toxicology but before it can be successfully implemented that there are some challenges that must be addressed. Although the advantages of the LDTD system include minimal maintenance and rapid analysis (∼10 s per sample) which makes it ideal for high-throughput forensic laboratories, a major disadvantage is its inability or difficulty analyzing isomers and isobars due to the lack of chromatography without the use of high-resolution MS; therefore, it would be best implemented as a screening technique. © The Author 2014. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

  15. Progressive Precision Surface Design

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Duchaineau, M; Joy, KJ

    2002-01-11

    We introduce a novel wavelet decomposition algorithm that makes a number of powerful new surface design operations practical. Wavelets, and hierarchical representations generally, have held promise to facilitate a variety of design tasks in a unified way by approximating results very precisely, thus avoiding a proliferation of undergirding mathematical representations. However, traditional wavelet decomposition is defined from fine to coarse resolution, thus limiting its efficiency for highly precise surface manipulation when attempting to create new non-local editing methods. Our key contribution is the progressive wavelet decomposition algorithm, a general-purpose coarse-to-fine method for hierarchical fitting, based in this paper on anmore » underlying multiresolution representation called dyadic splines. The algorithm requests input via a generic interval query mechanism, allowing a wide variety of non-local operations to be quickly implemented. The algorithm performs work proportionate to the tiny compressed output size, rather than to some arbitrarily high resolution that would otherwise be required, thus increasing performance by several orders of magnitude. We describe several design operations that are made tractable because of the progressive decomposition. Free-form pasting is a generalization of the traditional control-mesh edit, but for which the shape of the change is completely general and where the shape can be placed using a free-form deformation within the surface domain. Smoothing and roughening operations are enhanced so that an arbitrary loop in the domain specifies the area of effect. Finally, the sculpting effect of moving a tool shape along a path is simulated.« less

  16. Rodriguez and Pennington Address Proteogenomics and Data Sharing in the Journal Cell | Office of Cancer Clinical Proteomics Research

    Cancer.gov

    Precision medicine is an approach that allows doctors to understand how a patient's genetic profile may cause cancer to grow and spread, leading to a more personalized treatment strategy based on molecular characterization of a person's tumor. However, precision medicine as a genomics-based approach does not yet apply to all patients because genetic mutations do not always lead to changes of the corresponding proteins. Therefore, integrating genomics and proteomics data, or proteogenomics, presents as a new approach that may help make precision medicine a more effective treatment option for patients.

  17. Thermodynamic Bounds on Precision in Ballistic Multiterminal Transport

    NASA Astrophysics Data System (ADS)

    Brandner, Kay; Hanazato, Taro; Saito, Keiji

    2018-03-01

    For classical ballistic transport in a multiterminal geometry, we derive a universal trade-off relation between total dissipation and the precision, at which particles are extracted from individual reservoirs. Remarkably, this bound becomes significantly weaker in the presence of a magnetic field breaking time-reversal symmetry. By working out an explicit model for chiral transport enforced by a strong magnetic field, we show that our bounds are tight. Beyond the classical regime, we find that, in quantum systems far from equilibrium, the correlated exchange of particles makes it possible to exponentially reduce the thermodynamic cost of precision.

  18. An Improved Flow Cytometry Method For Precise Quantitation Of Natural-Killer Cell Activity

    NASA Technical Reports Server (NTRS)

    Crucian, Brian; Nehlsen-Cannarella, Sandra; Sams, Clarence

    2006-01-01

    The ability to assess NK cell cytotoxicity using flow cytometry has been previously described and can serve as a powerful tool to evaluate effector immune function in the clinical setting. Previous methods used membrane permeable dyes to identify target cells. The use of these dyes requires great care to achieve optimal staining and results in a broad spectral emission that can make multicolor cytometry difficult. Previous methods have also used negative staining (the elimination of target cells) to identify effector cells. This makes a precise quantitation of effector NK cells impossible due to the interfering presence of T and B lymphocytes, and the data highly subjective to the variable levels of NK cells normally found in human peripheral blood. In this study an improved version of the standard flow cytometry assay for NK activity is described that has several advantages of previous methods. Fluorescent antibody staining (CD45FITC) is used to positively identify target cells in place of membranepermeable dyes. Fluorescent antibody staining of target cells is less labor intensive and more easily reproducible than membrane dyes. NK cells (true effector lymphocytes) are also positively identified by fluorescent antibody staining (CD56PE) allowing a simultaneous absolute count assessment of both NK cells and target cells. Dead cells are identified by membrane disruption using the DNA intercalating dye PI. Using this method, an exact NK:target ratio may be determined for each assessment, including quantitation of NK target complexes. Backimmunoscatter gating may be used to track live vs. dead Target cells via scatter properties. If desired, NK activity may then be normalized to standardized ratios for clinical comparisons between patients, making the determination of PBMC counts or NK cell percentages prior to testing unnecessary. This method provides an exact cytometric determination of NK activity that highly reproducible and may be suitable for routine use in the clinical setting.

  19. Note: High precision measurements using high frequency gigahertz signals

    NASA Astrophysics Data System (ADS)

    Jin, Aohan; Fu, Siyuan; Sakurai, Atsunori; Liu, Liang; Edman, Fredrik; Pullerits, Tõnu; Öwall, Viktor; Karki, Khadga Jung

    2014-12-01

    Generalized lock-in amplifiers use digital cavities with Q-factors as high as 5 × 108 to measure signals with very high precision. In this Note, we show that generalized lock-in amplifiers can be used to analyze microwave (giga-hertz) signals with a precision of few tens of hertz. We propose that the physical changes in the medium of propagation can be measured precisely by the ultra-high precision measurement of the signal. We provide evidence to our proposition by verifying the Newton's law of cooling by measuring the effect of change in temperature on the phase and amplitude of the signals propagating through two calibrated cables. The technique could be used to precisely measure different physical properties of the propagation medium, for example, the change in length, resistance, etc. Real time implementation of the technique can open up new methodologies of in situ virtual metrology in material design.

  20. Delivery of Formulated Industrial Enzymes with Acoustic Technology.

    PubMed

    Hwang, Jennifer Dorcas; Ortiz-Maldonado, Mariliz; Paramonov, Sergey

    2016-02-01

    Industrial enzymes are instrumental in many applications, including carbohydrate processing, fabric and household care, biofuels, food, and animal nutrition, among others. Enzymes have to be active and stable not only in harsh application conditions, but also during shipment and storage. In protein stability studies, formulated concentrated enzyme solutions are frequently diluted gravimetrically prior to enzyme activity measurements, making it challenging to move toward more high-throughput techniques using conventional robotic equipment. Current assay methods pose difficulties when measuring highly concentrated proteins. For example, plastic pipette tips can introduce error because proteins adsorb to the tip surface, despite the presence of detergents, decreasing precision and overall efficiency of protein activity assays. Acoustic liquid handling technology, frequently used for various dilute small-molecule assays, may overcome such problems. Originally shown to effectively deliver dilute solutions of small molecules, this technology is used here as an effective alternative to the aforementioned challenge with viscous concentrated protein solutions. Because the acoustic liquid handler transfers nanoliter quantities of liquids without using pipette tips and without sample loss, it rapidly and uniformly prepares assay plates for enzyme activity measurements within minutes. This increased efficiency transforms the nature of enzyme stability studies toward high precision and throughput. © 2015 Society for Laboratory Automation and Screening.

  1. Analysis and Compensation of Modulation Angular Rate Error Based on Missile-Borne Rotation Semi-Strapdown Inertial Navigation System

    PubMed Central

    Zhang, Jiayu; Li, Jie; Zhang, Xi; Che, Xiaorui; Huang, Yugang; Feng, Kaiqiang

    2018-01-01

    The Semi-Strapdown Inertial Navigation System (SSINS) provides a new solution to attitude measurement of a high-speed rotating missile. However, micro-electro-mechanical-systems (MEMS) inertial measurement unit (MIMU) outputs are corrupted by significant sensor errors. In order to improve the navigation precision, a rotation modulation technology method called Rotation Semi-Strapdown Inertial Navigation System (RSSINS) is introduced into SINS. In fact, the stability of the modulation angular rate is difficult to achieve in a high-speed rotation environment. The changing rotary angular rate has an impact on the inertial sensor error self-compensation. In this paper, the influence of modulation angular rate error, including acceleration-deceleration process, and instability of the angular rate on the navigation accuracy of RSSINS is deduced and the error characteristics of the reciprocating rotation scheme are analyzed. A new compensation method is proposed to remove or reduce sensor errors so as to make it possible to maintain high precision autonomous navigation performance by MIMU when there is no external aid. Experiments have been carried out to validate the performance of the method. In addition, the proposed method is applicable for modulation angular rate error compensation under various dynamic conditions. PMID:29734707

  2. NIAC Phase I Study Final Report on Large Ultra-Lightweight Photonic Muscle Space Structures

    NASA Technical Reports Server (NTRS)

    Ritter, Joe

    2016-01-01

    The research goal is to develop new tools support NASA's mission of understanding of the Cosmos by developing cost effective solutions that yield a leap in performance and science data. 'Maikalani' in Hawaiian translates to, "knowledge we gain from the cosmos." Missions like Hubble have fundamentally changed humanity's view of the cosmos. Last year's Nobel prize in physics was a result of astronomical discoveries. $9B class JWST size (6.5 meter diameter) space telescopes, when launched are anticipated to rewrite our knowledge of physics. Here we report on a neoteric meta-material telescope mirror technology designed to enable a factor of 100 or more reduction in areal density, a factor of 100 reduction in telescope production and launch costs as well as other advantages; a leap to enable missions to image the cosmos in unprecedented detail, with the associated gain in knowledge. Whether terahertz, visible or X-ray, reflectors used for high quality electromagnetic imaging require shape accuracy (surface figure) to far better than 1 wavelength (lambda) of the incident photons, more typically lambda/10 or better. Imaging visible light therefore requires mirror surfaces that approximate a desired curve (e.g. a sphere or paraboloid) with smooth shape deviation of th less than approximately 1/1000 the diameter of a human hair. This requires either thick high modulus material like glass or metal, or actuators to control mirror shape. During Phase I our team studied a novel solution to this systems level design mass/shape tradespace requirement both to advance the innovative space technology concept and also to help NASA and other agencies meet current operational and future mission requirements. Extreme and revolutionary NASA imaging missions such as Terrestrial Planet Imager (TPI) require lightweight mirrors with minimum diameters of 20 to 40 meters. For reference, NASA's great achievement; the Hubble space telescope, is only 2.4 meters in diameter. What is required is a way to make large inexpensive deployable mirrors where the cost is measured in millions, not billions like current efforts. For example we seek an interim goal within 10 years of a Hubble size (2.4m) primary mirror weighing 1 pound at a cost of 10K in materials. Described here is a technology using thin ultra lightweight materials where shape can be controlled simply with a beam of light, allowing imaging with incredibly low mass yet precisely shaped mirrors. These " Photonic Muscle" substrates will eventually make precision control of giant s p a c e apertures (mirrors) possible. OCCAM substrates make precision control of giant ultra light-weight mirror apertures possible. This technology is posed to create a revolution in remote sensing by making large ultra lightweight space telescopes a fiscal and material reality over the next decade.

  3. Numerical Simulation Analysis of High-precision Dispensing Needles for Solid-liquid Two-phase Grinding

    NASA Astrophysics Data System (ADS)

    Li, Junye; Hu, Jinglei; Wang, Binyu; Sheng, Liang; Zhang, Xinming

    2018-03-01

    In order to investigate the effect of abrasive flow polishing surface variable diameter pipe parts, with high precision dispensing needles as the research object, the numerical simulation of the process of polishing high precision dispensing needle was carried out. Analysis of different volume fraction conditions, the distribution of the dynamic pressure and the turbulence viscosity of the abrasive flow field in the high precision dispensing needle, through comparative analysis, the effectiveness of the abrasive grain polishing high precision dispensing needle was studied, controlling the volume fraction of silicon carbide can change the viscosity characteristics of the abrasive flow during the polishing process, so that the polishing quality of the abrasive grains can be controlled.

  4. Development of a new bench for puncturing of irradiated fuel rods in STAR hot laboratory

    NASA Astrophysics Data System (ADS)

    Petitprez, B.; Silvestre, P.; Valenza, P.; Boulore, A.; David, T.

    2018-01-01

    A new device for puncturing of irradiated fuel rods in commercial power plants has been designed by Fuel Research Department of CEA Cadarache in order to provide experimental data of high precision on fuel pins with various designs. It will replace the current set-up that has been used since 1998 in hot cell 2 of STAR facility with more than 200 rod puncturing experiments. Based on this consistent experimental feedback, the heavy-duty technique of rod perforation by clad punching has been preserved for the new bench. The method of double expansion of rod gases is also retained since it allows upgrading the confidence interval of volumetric results obtained from rod puncturing. Furthermore, many evolutions have been introduced in the new design in order to improve its reliability, to make the maintenance easier by remote handling and to reduce experimental uncertainties. Tightness components have been studied with Sealing Laboratory Maestral at Pierrelatte so as to make them able to work under mixed pressure conditions (from vacuum at 10-5 mbar up to pressure at 50 bars) and to lengthen their lifetime under permanent gamma irradiation in hot cell. Bench ergonomics has been optimized to make its operating by remote handling easier and to secure the critical phases of a puncturing experiment. A high pressure gas line equipped with high precision pressure sensors out of cell can be connected to the bench in cell for calibration purposes. Uncertainty analyses using Monte Carlo calculations have been performed in order to optimize capacity of the different volumes of the apparatus according to volumetric characteristics of the rod to be punctured. At last this device is composed of independent modules which allow puncturing fuel pins out of different geometries (PWR, BWR, VVER). After leak tests of the device and remote handling simulation in a mock-up cell, several punctures of calibrated specimens have been performed in 2016. The bench will be implemented soon in hot cell 2 of STAR facility for final qualification tests. PWR rod punctures are already planned for 2018.

  5. NREL, NASA, and UCL Team Up to Make Lithium-Ion Batteries Safer on Earth

    Science.gov Websites

    and in Space | News | NREL NREL, NASA, and UCL Team Up to Make Lithium-Ion Batteries Safer on Earth and in Space NREL, NASA, and UCL Team Up to Make Lithium-Ion Batteries Safer on Earth and in Space . NREL joined forces with NASA in finding new, more precise ways to trigger internal short circuits

  6. Astronomical Prospecting of Asteroid Resources

    NASA Astrophysics Data System (ADS)

    Elvis, M.

    2017-09-01

    To make asteroid mining profitable will require professional astronomers using some of the largest telescopes on Earth to make precision measurements. This "astronomical prospecting" information is cheaper to obtain than flying even one or two spacecraft and will drastically cut the number of space probes that have to be sent to find an ore-bearing rock in space. Astronomical prospecting could make the business case for asteroid mining a solid one.

  7. In praise of vagueness: malleability of vague information as a performance booster.

    PubMed

    Mishra, Himanshu; Mishra, Arul; Shiv, Baba

    2011-06-01

    Is the eternal quest for precise information always worthwhile? Our research suggests that, at times, vagueness has its merits. Previous research has demonstrated that people prefer precise information over vague information because it gives them a sense of security and makes their environments more predictable. However, we show that the fuzzy boundaries afforded by vague information can actually help individuals perform better than can precise information. We document these findings across two laboratory studies and one quasi-field study that involved different performance-related contexts (mental acuity, physical strength, and weight loss). We argue that the malleability of vague information allows people to interpret it in the manner they desire, so that they can generate positive response expectancies and, thereby, perform better. The rigidity of precise information discourages desirable interpretations. Hence, on certain occasions, precise information is not as helpful as vague information in boosting performance.

  8. Gene expression during blow fly development: improving the precision of age estimates in forensic entomology.

    PubMed

    Tarone, Aaron M; Foran, David R

    2011-01-01

    Forensic entomologists use size and developmental stage to estimate blow fly age, and from those, a postmortem interval. Since such estimates are generally accurate but often lack precision, particularly in the older developmental stages, alternative aging methods would be advantageous. Presented here is a means of incorporating developmentally regulated gene expression levels into traditional stage and size data, with a goal of more precisely estimating developmental age of immature Lucilia sericata. Generalized additive models of development showed improved statistical support compared to models that did not include gene expression data, resulting in an increase in estimate precision, especially for postfeeding third instars and pupae. The models were then used to make blind estimates of development for 86 immature L. sericata raised on rat carcasses. Overall, inclusion of gene expression data resulted in increased precision in aging blow flies. © 2010 American Academy of Forensic Sciences.

  9. Research on the phase adjustment method for dispersion interferometer on HL-2A tokamak

    NASA Astrophysics Data System (ADS)

    Tongyu, WU; Wei, ZHANG; Haoxi, WANG; Yan, ZHOU; Zejie, YIN

    2018-06-01

    A synchronous demodulation system is proposed and deployed for CO2 dispersion interferometer on HL-2A, which aims at high plasma density measurements and real-time feedback control. In order to make sure that the demodulator and the interferometer signal are synchronous in phase, a phase adjustment (PA) method has been developed for the demodulation system. The method takes advantages of the field programmable gate array parallel and pipeline process capabilities to carry out high performance and low latency PA. Some experimental results presented show that the PA method is crucial to the synchronous demodulation system and reliable to follow the fast change of the electron density. The system can measure the line-integrated density with a high precision of 2.0 × 1018 m‑2.

  10. Model-Based Localization and Tracking Using Bluetooth Low-Energy Beacons

    PubMed Central

    Cemgil, Ali Taylan

    2017-01-01

    We introduce a high precision localization and tracking method that makes use of cheap Bluetooth low-energy (BLE) beacons only. We track the position of a moving sensor by integrating highly unreliable and noisy BLE observations streaming from multiple locations. A novel aspect of our approach is the development of an observation model, specifically tailored for received signal strength indicator (RSSI) fingerprints: a combination based on the optimal transport model of Wasserstein distance. The tracking results of the entire system are compared with alternative baseline estimation methods, such as nearest neighboring fingerprints and an artificial neural network. Our results show that highly accurate estimation from noisy Bluetooth data is practically feasible with an observation model based on Wasserstein distance interpolation combined with the sequential Monte Carlo (SMC) method for tracking. PMID:29109375

  11. Model-Based Localization and Tracking Using Bluetooth Low-Energy Beacons.

    PubMed

    Daniş, F Serhan; Cemgil, Ali Taylan

    2017-10-29

    We introduce a high precision localization and tracking method that makes use of cheap Bluetooth low-energy (BLE) beacons only. We track the position of a moving sensor by integrating highly unreliable and noisy BLE observations streaming from multiple locations. A novel aspect of our approach is the development of an observation model, specifically tailored for received signal strength indicator (RSSI) fingerprints: a combination based on the optimal transport model of Wasserstein distance. The tracking results of the entire system are compared with alternative baseline estimation methods, such as nearest neighboring fingerprints and an artificial neural network. Our results show that highly accurate estimation from noisy Bluetooth data is practically feasible with an observation model based on Wasserstein distance interpolation combined with the sequential Monte Carlo (SMC) method for tracking.

  12. 2-Micron Pulsed Direct Detection IPDA Lidar for Atmospheric CO2 Measurement

    NASA Technical Reports Server (NTRS)

    Yu, Jirong; Petros, Mulugeta; Refaat, Tamer; Reithmaier, Karl; Remus, Ruben; Singh, Upendra; Johnson, Will; Boyer, Charlie; Fay, James; Johnston, Susan; hide

    2014-01-01

    A 2-micron high energy, pulsed Integrated Path Differential Absorption (IPDA) lidar has been developed for atmospheric CO2 measurements. Development of this lidar heavily leverages the 2-micron laser technologies developed in LaRC over the last decade. The high pulse energy, direct detection lidar operating at CO2 2-micron absorption band provides an alternate approach to measure CO2 concentrations. This new 2-micron pulsed IPDA lidar has been flown in spring of this year for total ten flights with 27 flight hours. It is able to make measurements of the total amount of atmospheric CO2 from the aircraft to the ground or cloud. It is expected to provide high-precision measurement capability by unambiguously eliminating contamination from aerosols and clouds that can bias the IPDA measurement.

  13. Hybrid Fabry-Perot interferometer for simultaneous liquid refractive index and temperature measurement.

    PubMed

    Xu, Ben; Yang, Yi; Jia, Zhenbao; Wang, D N

    2017-06-26

    A compact and high sensitivity sensor with a fiber-tip structure is proposed and demonstrated for simultaneously liquid refractive index (RI) and temperature sensing. The device is fabricated by inserting a tiny segment of capillary tube between single-mode fibers (SMFs) to form two cascaded Fabry-Perot interferometers (FPIs). The theoretical and experimental results demonstrate that the ambient liquid RI and temperature can be simultaneously determined by the intensity and shift of the resonant wavelength in the reflection spectrum. Our proposed device has the highest RI sensitivity of ~216.37 dB/RIU at the RI value of 1.30; a high spatial resolution owing to its compact size (with dimension <400 μm) makes it promising for high precision bio/chemical sensing applications.

  14. Belt-MRF for large aperture mirrors.

    PubMed

    Ren, Kai; Luo, Xiao; Zheng, Ligong; Bai, Yang; Li, Longxiang; Hu, Haixiang; Zhang, Xuejun

    2014-08-11

    With high-determinacy and no subsurface damage, Magnetorheological Finishing (MRF) has become an important tool in fabricating high-precision optics. But for large mirrors, the application of MRF is restricted by its small removal function and low material removal rate. In order to improve the material removal rate, shorten the processing cycle, we proposed a new MRF concept, named Belt-MRF to expand the application of MRF to large mirrors and made a prototype with a large remove function, using a belt instead of a very large polishing wheel to expand the polishing length. A series of experimental results on Silicon carbide (SiC) and BK 7 specimens and fabrication simulation verified that the Belt-MRF has high material removal rates, stable removal function and high convergence efficiency which makes it a promising technology for processing large aperture optical elements.

  15. Super-smooth processing x-ray telescope application research based on the magnetorheological finishing (MRF) technology

    NASA Astrophysics Data System (ADS)

    Zhong, Xianyun; Hou, Xi; Yang, Jinshan

    2016-09-01

    Nickel is the unique material in the X-ray telescopes. And it has the typical soft material characteristics with low hardness high surface damage and low stability of thermal. The traditional fabrication techniques are exposed to lots of problems, including great surface scratches, high sub-surface damage and poor surface roughness and so on. The current fabrication technology for the nickel aspheric mainly adopt the single point diamond turning(SPDT), which has lots of advantages such as high efficiency, ultra-precision surface figure, low sub-surface damage and so on. But the residual surface texture of SPDT will cause great scattering losses and fall far short from the requirement in the X-ray applications. This paper mainly investigates the magnetorheological finishing (MRF) techniques for the super-smooth processing on the nickel optics. Through the study of the MRF polishing techniques, we obtained the ideal super-smooth polishing technique based on the self-controlled MRF-fluid NS-1, and finished the high-precision surface figure lower than RMS λ/80 (λ=632.8nm) and super-smooth roughness lower than Ra 0.3nm on the plane reflector and roughness lower than Ra 0.4nm on the convex cone. The studying of the MRF techniques makes a great effort to the state-of-the-art nickel material processing level for the X-ray optical systems applications.

  16. High-Precision U-Pb Geochronology of Ice River Perovskite: A Possible Interlaboratory and Intertechnique EARTHTIME Standard

    NASA Astrophysics Data System (ADS)

    Burgess, S. D.; Bowring, S. A.; Heaman, L. M.

    2012-12-01

    Accurate and precise U-Pb geochronology of accessory phases other than zircon are required for dating some LIP basalts or determining the temporal patterns of kimberlite pipes, for example. Advances in precision and accuracy lead directly to an increase in the complexity of questions that can be posed. U-Pb geochronology of perovskite (CaTiO3) has been applied to silica-undersaturated basalts, carbonatites, alkaline igneous rocks, and kimberlites. Most published IDTIMS perovskite dates have 2-sigma precisions at the ~0.2% level for weighted mean 206Pb/238U dates, much less than possible with IDTIMS analyses of zircons, which limits the applicability of perovskite in high-precision applications. Precision on perovskite dates is lower than zircon because of common Pb, which in some cases can be up to 50% of the total Pb and must be corrected for and accurately partitioned between blank and initial. Relatively small changes in the composition of common Pb can result in inaccurate but precise dates. In many cases minerals with significant common Pb are corrected using Stacey and Kramers (1975) two stage Pb evolution model. This can be done without serious consequence to the final date for minerals with high U/Pb ratios. In the more common case where U/Pb ratios are relatively low and the proportion of common Pb is large, applying a model-derived Pb isotopic composition rather than measuring it directly can introduce percent-level inaccuracy to dates calculated with precisely known U/Pb ratios. Direct measurement of the common Pb composition can be done on a U-poor mineral that co-crystallized with perovskite; feldspar and clinopyroxene are commonly used. Clinopyroxene can contain significant in-grown radiogenic Pb and our experiments indicate that it is not eliminated by aggressive step-wise leaching. The U/Pb ratio in clinopyroxene is generally low (20 < mu < 50) but significant. Other workers (e.g. Kamo et al., 2003; Corfu and Dahlgren, 2008), have used two methods to determine the amount of ingrown Pb. First, by measuring the U/Pb ratio in clinopyroxene and assuming a crystallization age the amount of ingrown Pb can be calculated. Second, by assuming that perovskite and clinopyroxene (± other phases) are isochronous, the initial Pb isotopic composition can be calculated using the y-intercept on 206Pb/238U, 207Pb/235U, and 3-D isochron diagrams. To further develop a perovskite mineral standard for use in high-precision dating applications, we have focused on single grains/fragments of perovskite and multi-grain clinopyroxene fractions from a melteigite sample (IR90.3) within the Ice River complex, a zoned alkaline-ultramafic intrusion in southeastern British Columbia. Perovskite from this sample has variable measured 206Pb/204Pb (22-263), making this an ideal sample on which to test the sensitivity of the date on grains with variable amounts of radiogenic Pb to changes in common Pb composition. Using co-existing clinopyroxene for the initial common Pb composition by both direct measurement and by the isochron method allows us to calculate an accurate weighted-mean 206Pb/238U date on perovskite at the < 0.1% level, which overlaps within uncertainty for the two different methods. We recommend the Ice River 90.3 perovskite as a suitable EARTHTIME standard for interlaboratory and intertechnique comparison.

  17. A precision analogue integrator system for heavy current measurement in MFDC resistance spot welding

    NASA Astrophysics Data System (ADS)

    Xia, Yu-Jun; Zhang, Zhong-Dian; Xia, Zhen-Xin; Zhu, Shi-Liang; Zhang, Rui

    2016-02-01

    In order to control and monitor the quality of middle frequency direct current (MFDC) resistance spot welding (RSW), precision measurement of the welding current up to 100 kA is required, for which Rogowski coils are the only viable current transducers at present. Thus, a highly accurate analogue integrator is the key to restoring the converted signals collected from the Rogowski coils. Previous studies emphasised that the integration drift is a major factor that influences the performance of analogue integrators, but capacitive leakage error also has a significant impact on the result, especially in long-time pulse integration. In this article, new methods of measuring and compensating capacitive leakage error are proposed to fabricate a precision analogue integrator system for MFDC RSW. A voltage holding test is carried out to measure the integration error caused by capacitive leakage, and an original integrator with a feedback adder is designed to compensate capacitive leakage error in real time. The experimental results and statistical analysis show that the new analogue integrator system could constrain both drift and capacitive leakage error, of which the effect is robust to different voltage levels of output signals. The total integration error is limited within  ±0.09 mV s-1 0.005% s-1 or full scale at a 95% confidence level, which makes it possible to achieve the precision measurement of the welding current of MFDC RSW with Rogowski coils of 0.1% accuracy class.

  18. Precision resection of lung cancer in a sheep model using ultrashort laser pulses

    NASA Astrophysics Data System (ADS)

    Beck, Rainer J.; Mohanan, Syam Mohan P. C.; Góra, Wojciech S.; Cousens, Chris; Finlayson, Jeanie; Dagleish, Mark P.; Griffiths, David J.; Shephard, Jonathan D.

    2017-02-01

    Recent developments and progress in the delivery of high average power ultrafast laser pulses enable a range of novel minimally invasive surgical procedures. Lung cancer is the leading cause of cancer deaths worldwide and here the resection of lung tumours by means of picosecond laser pulses is presented. This represents a potential alternative to mitigate limitations of existing surgical treatments in terms of precision and collateral thermal damage to the healthy tissue. Robust process parameters for the laser resection are demonstrated using ovine pulmonary adenocarcinoma (OPA). OPA is a naturally occurring lung cancer of sheep caused by retrovirus infection that has several features in common with some forms of human pulmonary adenocarcinoma, including a similar histological appearance, which makes it ideally suited for this study. The picosecond laser was operated at a wavelength of 515 nm to resect square cavities from fresh ex-vivo OPA samples using a range of scanning strategies. Process parameters are presented for efficient ablation of the tumour with clear margins and only minimal collateral damage to the surrounding tissue. The resection depth can be controlled precisely by means of the pulse energy. By adjusting the overlap between successive laser pulses, deliberate heat transfer to the tissue and thermal damage can be achieved. This can be beneficial for on demand haemostasis and laser coagulation. Overall, the application of ultrafast lasers for the resection of lung tumours has potential to enable significantly improved precision and reduced thermal damage to the surrounding tissue compared to conventional techniques.

  19. High precision gas hydrate imaging of small-scale and high-resolution marine sparker multichannel seismic data

    NASA Astrophysics Data System (ADS)

    Luo, D.; Cai, F.

    2017-12-01

    Small-scale and high-resolution marine sparker multi-channel seismic surveys using large energy sparkers are characterized by a high dominant frequency of the seismic source, wide bandwidth, and a high resolution. The technology with a high-resolution and high-detection precision was designed to improve the imaging quality of shallow sedimentary. In the study, a 20KJ sparker and 24-channel streamer cable with a 6.25m group interval were used as a seismic source and receiver system, respectively. Key factors for seismic imaging of gas hydrate are enhancement of S/N ratio, amplitude compensation and detailed velocity analysis. However, the data in this study has some characteristics below: 1. Small maximum offsets are adverse to velocity analysis and multiple attenuation. 2. Lack of low frequency information, that is, information less than 100Hz are invisible. 3. Low S/N ratio since less coverage times (only 12 times). These characteristics make it difficult to reach the targets of seismic imaging. In the study, the target processing methods are used to improve the seismic imaging quality of gas hydrate. First, some technologies of noise suppression are combined used in pre-stack seismic data to suppression of seismic noise and improve the S/N ratio. These technologies including a spectrum sharing noise elimination method, median filtering and exogenous interference suppression method. Second, the combined method of three technologies including SRME, τ-p deconvolution and high precision Radon transformation is used to remove multiples. Third, accurate velocity field are used in amplitude energy compensation to highlight the Bottom Simulating Reflector (short for BSR, the indicator of gas hydrates) and gas migration pathways (such as gas chimneys, hot spots et al.). Fourth, fine velocity analysis technology are used to improve accuracy of velocity analysis. Fifth, pre-stack deconvolution processing technology is used to compensate for low frequency energy and suppress of ghost, thus formation reflection characteristics are highlighted. The result shows that the small-scale and high resolution marine sparker multi-channel seismic surveys are very effective in improving the resolution and quality of gas hydrate imaging than the conventional seismic acquisition technology.

  20. High-Precision Registration of Point Clouds Based on Sphere Feature Constraints.

    PubMed

    Huang, Junhui; Wang, Zhao; Gao, Jianmin; Huang, Youping; Towers, David Peter

    2016-12-30

    Point cloud registration is a key process in multi-view 3D measurements. Its precision affects the measurement precision directly. However, in the case of the point clouds with non-overlapping areas or curvature invariant surface, it is difficult to achieve a high precision. A high precision registration method based on sphere feature constraint is presented to overcome the difficulty in the paper. Some known sphere features with constraints are used to construct virtual overlapping areas. The virtual overlapping areas provide more accurate corresponding point pairs and reduce the influence of noise. Then the transformation parameters between the registered point clouds are solved by an optimization method with weight function. In that case, the impact of large noise in point clouds can be reduced and a high precision registration is achieved. Simulation and experiments validate the proposed method.

  1. High-Precision Registration of Point Clouds Based on Sphere Feature Constraints

    PubMed Central

    Huang, Junhui; Wang, Zhao; Gao, Jianmin; Huang, Youping; Towers, David Peter

    2016-01-01

    Point cloud registration is a key process in multi-view 3D measurements. Its precision affects the measurement precision directly. However, in the case of the point clouds with non-overlapping areas or curvature invariant surface, it is difficult to achieve a high precision. A high precision registration method based on sphere feature constraint is presented to overcome the difficulty in the paper. Some known sphere features with constraints are used to construct virtual overlapping areas. The virtual overlapping areas provide more accurate corresponding point pairs and reduce the influence of noise. Then the transformation parameters between the registered point clouds are solved by an optimization method with weight function. In that case, the impact of large noise in point clouds can be reduced and a high precision registration is achieved. Simulation and experiments validate the proposed method. PMID:28042846

  2. All-optical lithography process for contacting nanometer precision donor devices

    NASA Astrophysics Data System (ADS)

    Ward, D. R.; Marshall, M. T.; Campbell, D. M.; Lu, T. M.; Koepke, J. C.; Scrymgeour, D. A.; Bussmann, E.; Misra, S.

    2017-11-01

    We describe an all-optical lithography process that can make electrical contact to nanometer-precision donor devices fabricated in silicon using scanning tunneling microscopy (STM). This is accomplished by implementing a cleaning procedure in the STM that allows the integration of metal alignment marks and ion-implanted contacts at the wafer level. Low-temperature transport measurements of a patterned device establish the viability of the process.

  3. All-optical lithography process for contacting nanometer precision donor devices

    DOE PAGES

    Ward, Daniel Robert; Marshall, Michael Thomas; Campbell, DeAnna Marie; ...

    2017-11-06

    In this article, we describe an all-optical lithography process that can make electrical contact to nanometer-precision donor devices fabricated in silicon using scanning tunneling microscopy (STM). This is accomplished by implementing a cleaning procedure in the STM that allows the integration of metal alignment marks and ion-implanted contacts at the wafer level. Low-temperature transport measurements of a patterned device establish the viability of the process.

  4. Characterizing the Hypermutated Subtype of Advanced Prostate Cancer as a Predictive Biomarker for Precision Medicine

    DTIC Science & Technology

    2017-10-01

    goal of this research is to characterize the mechanisms leading to hypermutated prostate cancer and to integrate tumor hypermutation status with... integrate tumor hypermutation status with clinical decision making and therapy to improve the care of men with advanced prostate cancer. Using Next-Gen...preparation of presentations that integrate prostate cancer patient clinical histories with genomic findings 1-36 Yes, see Prostate Precision Tumor

  5. Detectors for Linear Colliders: Tracking and Vertexing (2/4)

    ScienceCinema

    Battaglia, Marco

    2018-04-16

    Efficient and precise determination of the flavour of partons in multi-hadron final states is essential to the anticipated LC physics program. This makes tracking in the vicinity of the interaction region of great importance. Tracking extrapolation and momentum resolution are specified by precise physics requirements. The R&D; towards detectors able to meet these specifications will be discussed, together with some of their application beyond particle physics.

  6. Opticians as astronauts. [for space station assembly of large precision telescopes

    NASA Technical Reports Server (NTRS)

    Angel, J. R. P.

    1986-01-01

    One of the most useful tasks to be carried out at the Space Station will be the making of large precision telescopes. It will become possible to assemble optics bigger than can be launched in one piece. A further step would be to take advantage of extraordinarily favorable conditions in space for testing and even manufacturing optics. In this short paper, these two aspects are considered.

  7. All-optical lithography process for contacting nanometer precision donor devices

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Ward, Daniel Robert; Marshall, Michael Thomas; Campbell, DeAnna Marie

    In this article, we describe an all-optical lithography process that can make electrical contact to nanometer-precision donor devices fabricated in silicon using scanning tunneling microscopy (STM). This is accomplished by implementing a cleaning procedure in the STM that allows the integration of metal alignment marks and ion-implanted contacts at the wafer level. Low-temperature transport measurements of a patterned device establish the viability of the process.

  8. Precision metabolic engineering: The design of responsive, selective, and controllable metabolic systems.

    PubMed

    McNerney, Monica P; Watstein, Daniel M; Styczynski, Mark P

    2015-09-01

    Metabolic engineering is generally focused on static optimization of cells to maximize production of a desired product, though recently dynamic metabolic engineering has explored how metabolic programs can be varied over time to improve titer. However, these are not the only types of applications where metabolic engineering could make a significant impact. Here, we discuss a new conceptual framework, termed "precision metabolic engineering," involving the design and engineering of systems that make different products in response to different signals. Rather than focusing on maximizing titer, these types of applications typically have three hallmarks: sensing signals that determine the desired metabolic target, completely directing metabolic flux in response to those signals, and producing sharp responses at specific signal thresholds. In this review, we will first discuss and provide examples of precision metabolic engineering. We will then discuss each of these hallmarks and identify which existing metabolic engineering methods can be applied to accomplish those tasks, as well as some of their shortcomings. Ultimately, precise control of metabolic systems has the potential to enable a host of new metabolic engineering and synthetic biology applications for any problem where flexibility of response to an external signal could be useful. Copyright © 2015 International Metabolic Engineering Society. Published by Elsevier Inc. All rights reserved.

  9. Desired Precision in Multi-Objective Optimization: Epsilon Archiving or Rounding Objectives?

    NASA Astrophysics Data System (ADS)

    Asadzadeh, M.; Sahraei, S.

    2016-12-01

    Multi-objective optimization (MO) aids in supporting the decision making process in water resources engineering and design problems. One of the main goals of solving a MO problem is to archive a set of solutions that is well-distributed across a wide range of all the design objectives. Modern MO algorithms use the epsilon dominance concept to define a mesh with pre-defined grid-cell size (often called epsilon) in the objective space and archive at most one solution at each grid-cell. Epsilon can be set to the desired precision level of each objective function to make sure that the difference between each pair of archived solutions is meaningful. This epsilon archiving process is computationally expensive in problems that have quick-to-evaluate objective functions. This research explores the applicability of a similar but computationally more efficient approach to respect the desired precision level of all objectives in the solution archiving process. In this alternative approach each objective function is rounded to the desired precision level before comparing any new solution to the set of archived solutions that already have rounded objective function values. This alternative solution archiving approach is compared to the epsilon archiving approach in terms of efficiency and quality of archived solutions for solving mathematical test problems and hydrologic model calibration problems.

  10. Comparison of fecal egg counting methods in four livestock species.

    PubMed

    Paras, Kelsey L; George, Melissa M; Vidyashankar, Anand N; Kaplan, Ray M

    2018-06-15

    Gastrointestinal nematode parasites are important pathogens of all domesticated livestock species. Fecal egg counts (FEC) are routinely used for evaluating anthelmintic efficacy and for making targeted anthelmintic treatment decisions. Numerous FEC techniques exist and vary in precision and accuracy. These performance characteristics are especially important when performing fecal egg count reduction tests (FECRT). The objective of this study was to compare the accuracy and precision of three commonly used FEC methods and determine if differences existed among livestock species. In this study, we evaluated the modified-Wisconsin, 3-chamber (high-sensitivity) McMaster, and Mini-FLOTAC methods in cattle, sheep, horses, and llamas in three phases. In the first phase, we performed an egg-spiking study to assess the egg recovery rate and accuracy of the different FEC methods. In the second phase, we examined clinical samples from four different livestock species and completed multiple replicate FEC using each method. In the last phase, we assessed the cheesecloth straining step as a potential source of egg loss. In the egg-spiking study, the Mini-FLOTAC recovered 70.9% of the eggs, which was significantly higher than either the McMaster (P = 0.002) or Wisconsin (P = 0.002). In the clinical samples from ruminants, Mini-FLOTAC consistently yielded the highest EPG, revealing a significantly higher level of egg recovery (P < 0.0001). For horses and llamas, both McMaster and Mini-FLOTAC yielded significantly higher EPG than Wisconsin (P < 0.0001, P < 0.0001, P < 0.001, and P = 0.024). Mini-FLOTAC was the most accurate method and was the most precise test for both species of ruminants. The Wisconsin method was the most precise for horses and McMaster was more precise for llama samples. We compared the Wisconsin and Mini-FLOTAC methods using a modified technique where both methods were performed using either the Mini-FLOTAC sieve or cheesecloth. The differences in the estimated mean EPG on log scale between the Wisconsin and mini-FLOTAC methods when cheesecloth was used (P < 0.0001) and when cheesecloth was excluded (P < 0.0001) were significant, providing strong evidence that the straining step is an important source of error. The high accuracy and precision demonstrated in this study for the Mini-FLOTAC, suggest that this method can be recommended for routine use in all host species. The benefits of Mini-FLOTAC will be especially relevant when high accuracy is important, such as when performing FECRT. Copyright © 2018 Elsevier B.V. All rights reserved.

  11. Ramped PyrOx 14C With a Twist: Improving Radiocarbon Chronologies on Highly Detrital Marginal Antarctic Sediments

    NASA Astrophysics Data System (ADS)

    Subt, C.; Yoon, H.; Yoo, K. C.; Lee, J. I.; Domack, E. W.; Rosenheim, B. E.

    2016-02-01

    Highly detrital sediments can be difficult to date when the detritus includes material similar to that from which dates are sought. For radiocarbon dating, samples with a high degree of pre-aged detrital carbon contamination necessitate measurement of a very small portion of the sample to remove that contamination from the targeted component, even when using advanced techniques such as Ramped PyrOx (RP) 14C dating. Here we present three case studies of alternative RP approaches, producing accurate and precise chronologies for highly detrital sediments near the Larsen C ice shelf, near the Drygalski Ice Tongue in Ross Sea, and in Lapeyrère Bay, Anvers Island. For sediments where the proportion of organic carbon that was modern at the time of deposition is too small for a traditional AMS analysis after RP treatment, we have developed an innovative multiple RP analyses approach to minimize the cost in precision from using smaller temperature intervals, while maximizing the benefit in accuracy. Resulting sub ice-shelf chronologies show vastly improved dates down-core, significantly younger than the equivalent 14C chronology from the bulk acid insoluble organic (AIO) carbon with increasing ages down-core. By comparison, bulk AIO 14C dates in the study areas are not only older, but are subject to age reversals and nearly constant ages that make sedimentation rates impossible to resolve. Using our new approaches, we can reduce pre-aged carbon contamination in Lapeyrère Bay, and date sediments within layers of siliceous mud and ooze in the Ross Sea, and near the Larsen C ice shelf. Improved accuracy for 14C dates of highly detrital sediments can sometimes require the incorporation of a larger blank correction to account for multiple analyses, decreasing the precision. Application of this method refines ages of hard-to-date sediments, removing limits on what to include in a regional approach to chronicle ice shelf collapse.

  12. KELT-12b: A P ˜ 5 day, Highly Inflated Hot Jupiter Transiting a Mildly Evolved Hot Star

    NASA Astrophysics Data System (ADS)

    Stevens, Daniel J.; Collins, Karen A.; Gaudi, B. Scott; Beatty, Thomas G.; Siverd, Robert J.; Bieryla, Allyson; Fulton, Benjamin J.; Crepp, Justin R.; Gonzales, Erica J.; Coker, Carl T.; Penev, Kaloyan; Stassun, Keivan G.; Jensen, Eric L. N.; Howard, Andrew W.; Latham, David W.; Rodriguez, Joseph E.; Zambelli, Roberto; Bozza, Valerio; Reed, Phillip A.; Gregorio, Joao; Buchhave, Lars A.; Penny, Matthew T.; Pepper, Joshua; Berlind, Perry; Calchi Novati, Sebastiano; Calkins, Michael L.; D'Ago, Giuseppe; Eastman, Jason D.; Bayliss, D.; Colón, Knicole D.; Curtis, Ivan A.; DePoy, D. L.; Esquerdo, Gilbert A.; Gould, Andrew; Joner, Michael D.; Kielkopf, John F.; Labadie-Bartz, Jonathan; Lund, Michael B.; Manner, Mark; Marshall, Jennifer L.; McLeod, Kim K.; Oberst, Thomas E.; Pogge, Richard W.; Scarpetta, Gaetano; Stephens, Denise C.; Stockdale, Christopher; Tan, T. G.; Trueblood, Mark; Trueblood, Patricia

    2017-04-01

    We announce the discovery of KELT-12b, a highly inflated Jupiter-mass planet transiting the mildly evolved, V = 10.64 host star TYC 2619-1057-1. We followed up the initial transit signal in the KELT-North survey data with precise ground-based photometry, high-resolution spectroscopy, precise radial velocity measurements, and high-resolution adaptive optics imaging. Our preferred best-fit model indicates that the host star has {T}{eff} = 6279 ± 51 K, {log}{g}\\star = 3.89 ± 0.05, [Fe/H] = {0.19}-0.09+0.08, {M}* = {1.59}-0.09+0.07 {M}⊙ , and {R}* = 2.37 ± 0.17 {R}⊙ . The planetary companion has {M}{{P}} = 0.95 ± 0.14 {M}{{J}}, {R}{{P}} = {1.78}-0.16+0.17 {R}{{J}}, {log}{g}{{P}} = {2.87}-0.10+0.09, and density {ρ }{{P}} = {0.21}-0.05+0.07 g cm-3, making it one of the most inflated giant planets known. Furthermore, for future follow-up, we report a high-precision time of inferior conjunction in {{BJD}}{TDB} of 2,457,083.660459 ± 0.000894 and period of P=5.0316216+/- 0.000032 days. Despite the relatively large separation of ˜0.07 au implied by its ˜5.03-day orbital period, KELT-12b receives significant flux of {2.38}-0.29+0.32× {10}9 erg s-1 cm-2 from its host. We compare the radii and insolations of transiting gas giant planets around hot ({T}{eff}≥slant 6250 K) and cool stars, noting that the observed paucity of known transiting giants around hot stars with low insolation is likely due to selection effects. We underscore the significance of long-term ground-based monitoring of hot stars and space-based targeting of hot stars with the Transiting Exoplanet Survey Satellite to search for inflated gas giants in longer-period orbits.

  13. rpe v5: an emulator for reduced floating-point precision in large numerical simulations

    NASA Astrophysics Data System (ADS)

    Dawson, Andrew; Düben, Peter D.

    2017-06-01

    This paper describes the rpe (reduced-precision emulator) library which has the capability to emulate the use of arbitrary reduced floating-point precision within large numerical models written in Fortran. The rpe software allows model developers to test how reduced floating-point precision affects the result of their simulations without having to make extensive code changes or port the model onto specialized hardware. The software can be used to identify parts of a program that are problematic for numerical precision and to guide changes to the program to allow a stronger reduction in precision.The development of rpe was motivated by the strong demand for more computing power. If numerical precision can be reduced for an application under consideration while still achieving results of acceptable quality, computational cost can be reduced, since a reduction in numerical precision may allow an increase in performance or a reduction in power consumption. For simulations with weather and climate models, savings due to a reduction in precision could be reinvested to allow model simulations at higher spatial resolution or complexity, or to increase the number of ensemble members to improve predictions. rpe was developed with a particular focus on the community of weather and climate modelling, but the software could be used with numerical simulations from other domains.

  14. The Laser Ranging Experiment of the Lunar Reconnaissance Orbiter: Five Years of Operations and Data Analysis

    NASA Technical Reports Server (NTRS)

    Mao, Dandan; McGarry, Jan F.; Mazarico, Erwan; Neumann, Gregory A.; Sun, Xiaoli; Torrence, Mark H.; Zagwodzki, Thomas W.; Rowlands, David D.; Hoffman, Evan D.; Horvath, Julie E.; hide

    2016-01-01

    We describe the results of the Laser Ranging (LR) experiment carried out from June 2009 to September 2014 in order to make one-way time-of-flight measurements of laser pulses between Earth-based laser ranging stations and the Lunar Reconnaissance Orbiter (LRO) orbiting the Moon. Over 4,000 hours of successful LR data are obtained from 10 international ground stations. The 20-30 centimeter precision of the full-rate LR data is further improved to 5-10 centimeter after conversion into normal points. The main purpose of LR is to utilize the high accuracy normal point data to improve the quality of the LRO orbits, which are nomi- nally determined by the radiometric S-band tracking data. When independently used in the LRO precision orbit determination process with the high-resolution GRAIL (Gravity Recovery and Interior Laboratory) gravity model, LR data provide good orbit solutions, with an average difference of approximately 50 meters in total position, and approximately 20 centimeters in radial direction, compared to the definitive LRO trajectory. When used in combination with the S-band tracking data, LR data help to improve the orbit accuracy in the radial direction to approximately 15 centimeters. In order to obtain highly accurate LR range measurements for precise orbit determination results, it is critical to closely model the behavior of the clocks both at the ground stations and on the spacecraft. LR provides a unique data set to calibrate the spacecraft clock. The LRO spacecraft clock is characterized by the LR data to a timing knowledge of 0.015 milliseconds over the entire 5 years of LR operation. We here present both the engineering setup of the LR experiments and the detailed analysis results of the LR data.

  15. Improved algorithm of ray tracing in ICF cryogenic targets

    NASA Astrophysics Data System (ADS)

    Zhang, Rui; Yang, Yongying; Ling, Tong; Jiang, Jiabin

    2016-10-01

    The high precision ray tracing inside inertial confinement fusion (ICF) cryogenic targets plays an important role in the reconstruction of the three-dimensional density distribution by algebraic reconstruction technique (ART) algorithm. The traditional Runge-Kutta methods, which is restricted by the precision of the grid division and the step size of ray tracing, cannot make an accurate calculation in the case of refractive index saltation. In this paper, we propose an improved algorithm of ray tracing based on the Runge-Kutta methods and Snell's law of refraction to achieve high tracing precision. On the boundary of refractive index, we apply Snell's law of refraction and contact point search algorithm to ensure accuracy of the simulation. Inside the cryogenic target, the combination of the Runge-Kutta methods and self-adaptive step algorithm are employed for computation. The original refractive index data, which is used to mesh the target, can be obtained by experimental measurement or priori refractive index distribution function. A finite differential method is performed to calculate the refractive index gradient of mesh nodes, and the distance weighted average interpolation methods is utilized to obtain refractive index and gradient of each point in space. In the simulation, we take ideal ICF target, Luneberg lens and Graded index rod as simulation model to calculate the spot diagram and wavefront map. Compared the simulation results to Zemax, it manifests that the improved algorithm of ray tracing based on the fourth-order Runge-Kutta methods and Snell's law of refraction exhibits high accuracy. The relative error of the spot diagram is 0.2%, and the peak-to-valley (PV) error and the root-mean-square (RMS) error of the wavefront map is less than λ/35 and λ/100, correspondingly.

  16. Determination of the Kinematics of the Qweak Experiment and Investigation of an Atomic Hydrogen Moller Polarimeter

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Gray, Valerie M.

    The Q weak experiment has tested the Standard Model through making a precise measurement of the weak charge of the proton (more » $$Q^p_W$$). This was done through measuring the parity-violating asymmetry for polarized electrons scattering off of unpolarized protons. The parity-violating asymmetry measured is directly proportional to the four-momentum transfer ($Q^2$) from the electron to the proton. The extraction of $$Q^p_W$$ from the measured asymmetry requires a precise $Q^2$ determination. The Q weak experiment had a $Q^2$ = 24.8 ± 0.1 m(GeV 2) which achieved the goal of an uncertainty of <= 0.5%. From the measured asymmetry and $Q^2$, $$Q^p_W$$ was determined to be 0.0719 ± 0.0045, which is in good agreement with the Standard Model prediction. This puts a 7.5 TeV lower limit on possible "new physics". This dissertation describes the analysis of Q^2 for the Q weak experiment. Future parity-violating electron scattering experiments similar to the Q weak experiment will measure asymmetries to high precision in order to test the Standard Model. These measurements will require the beam polarization to be measured to sub-0.5% precision. Presently the electron beam polarization is measured through Moller scattering off of a ferromagnetic foil or through using Compton scattering, both of which can have issues reaching this precision. A novel Atomic Hydrogen Moller Polarimeter has been proposed as a non-invasive way to measure the polarization of an electron beam via Moller scattering off of polarized monatomic hydrogen gas. This dissertation describes the development and initial analysis of a Monte Carlo simulation of an Atomic Hydrogen Moller Polarimeter.« less

  17. A high-precision chronological model for the decorated Upper Paleolithic cave of Chauvet-Pont d'Arc, Ardèche, France.

    PubMed

    Quiles, Anita; Valladas, Hélène; Bocherens, Hervé; Delqué-Količ, Emmanuelle; Kaltnecker, Evelyne; van der Plicht, Johannes; Delannoy, Jean-Jacques; Feruglio, Valérie; Fritz, Carole; Monney, Julien; Philippe, Michel; Tosello, Gilles; Clottes, Jean; Geneste, Jean-Michel

    2016-04-26

    Radiocarbon dates for the ancient drawings in the Chauvet-Pont d'Arc Cave revealed ages much older than expected. These early ages and nature of this Paleolithic art make this United Nations Educational, Scientific and Cultural Organization (UNESCO) site indisputably unique. A large, multidisciplinary dating program has recently mapped the anthropological evolution associated with the cave. More than 350 dates (by (14)C, U-Th, TL and (36)Cl) were obtained over the last 15 y. They include 259 radiocarbon dates, mainly related to the rock art and human activity in the cave. We present here more than 80 previously unpublished dates. All of the dates were integrated into a high-precision Bayesian model based on archaeological evidence to securely reconstruct the complete history of the Chauvet-Pont d'Arc Cave on an absolute timescale. It shows that there were two distinct periods of human activity in the cave, one from 37 to 33,500 y ago, and the other from 31 to 28,000 y ago. Cave bears also took refuge in the cave until 33,000 y ago.

  18. A high-precision chronological model for the decorated Upper Paleolithic cave of Chauvet-Pont d’Arc, Ardèche, France

    PubMed Central

    Quiles, Anita; Valladas, Hélène; Bocherens, Hervé; Delqué-Količ, Emmanuelle; Kaltnecker, Evelyne; van der Plicht, Johannes; Delannoy, Jean-Jacques; Feruglio, Valérie; Fritz, Carole; Monney, Julien; Philippe, Michel; Tosello, Gilles; Clottes, Jean; Geneste, Jean-Michel

    2016-01-01

    Radiocarbon dates for the ancient drawings in the Chauvet-Pont d’Arc Cave revealed ages much older than expected. These early ages and nature of this Paleolithic art make this United Nations Educational, Scientific and Cultural Organization (UNESCO) site indisputably unique. A large, multidisciplinary dating program has recently mapped the anthropological evolution associated with the cave. More than 350 dates (by 14C, U-Th, TL and 36Cl) were obtained over the last 15 y. They include 259 radiocarbon dates, mainly related to the rock art and human activity in the cave. We present here more than 80 previously unpublished dates. All of the dates were integrated into a high-precision Bayesian model based on archaeological evidence to securely reconstruct the complete history of the Chauvet-Pont d’Arc Cave on an absolute timescale. It shows that there were two distinct periods of human activity in the cave, one from 37 to 33,500 y ago, and the other from 31 to 28,000 y ago. Cave bears also took refuge in the cave until 33,000 y ago. PMID:27071106

  19. Precision is essential for efficient catalysis in an evolved Kemp eliminase.

    PubMed

    Blomberg, Rebecca; Kries, Hajo; Pinkas, Daniel M; Mittl, Peer R E; Grütter, Markus G; Privett, Heidi K; Mayo, Stephen L; Hilvert, Donald

    2013-11-21

    Linus Pauling established the conceptual framework for understanding and mimicking enzymes more than six decades ago. The notion that enzymes selectively stabilize the rate-limiting transition state of the catalysed reaction relative to the bound ground state reduces the problem of design to one of molecular recognition. Nevertheless, past attempts to capitalize on this idea, for example by using transition state analogues to elicit antibodies with catalytic activities, have generally failed to deliver true enzymatic rates. The advent of computational design approaches, combined with directed evolution, has provided an opportunity to revisit this problem. Starting from a computationally designed catalyst for the Kemp elimination--a well-studied model system for proton transfer from carbon--we show that an artificial enzyme can be evolved that accelerates an elementary chemical reaction 6 × 10(8)-fold, approaching the exceptional efficiency of highly optimized natural enzymes such as triosephosphate isomerase. A 1.09 Å resolution crystal structure of the evolved enzyme indicates that familiar catalytic strategies such as shape complementarity and precisely placed catalytic groups can be successfully harnessed to afford such high rate accelerations, making us optimistic about the prospects of designing more sophisticated catalysts.

  20. Ridge augmentation with soft tissue procedures in aesthetic dentistry: first clinical results measured with a new kind of moire technique

    NASA Astrophysics Data System (ADS)

    Studer, Stephan P.; Bucher, Andreas; Mueller, Felix

    1993-09-01

    The oral health of the Swiss population was significantly improved by the successful prevention of dental caries and periodontitis. Along with the healthy dentition the demand for aesthetic dentistry is increasing. Removable partial dentures are becoming less accepted. Therefore, to substitute lost teeth by permanent fixed partial prosthesis (bridges), the often deformed alveolar ridge has to be operated, either to improve the aesthetic appearance or to make it possible to restore the missing teeth by a fixed cemented bridge. The aim of this paper is (1) to evaluate whether the moire technique is an appropriate and handy method, and (2) to validate the precision of the new method. The measuring system consisted of a moire projector with an integrated phase shift device and a moire viewer with a CCD video camera, connected to a frame grabber in a personal computer. a highly versatile software was allowed to control the system as well as to grab the moire images using the four-phase shift technique in order to compute the phase image of the actual object. The new technique was validated with one solid test object measured by a 3D coordination, high precision measuring machine.

  1. [A quick algorithm of dynamic spectrum photoelectric pulse wave detection based on LabVIEW].

    PubMed

    Lin, Ling; Li, Na; Li, Gang

    2010-02-01

    Dynamic spectrum (DS) detection is attractive among the numerous noninvasive blood component detection methods because of the elimination of the main interference of the individual discrepancy and measure conditions. DS is a kind of spectrum extracted from the photoelectric pulse wave and closely relative to the artery blood. It can be used in a noninvasive blood component concentration examination. The key issues in DS detection are high detection precision and high operation speed. The precision of measure can be advanced by making use of over-sampling and lock-in amplifying on the pick-up of photoelectric pulse wave in DS detection. In the present paper, the theory expression formula of the over-sampling and lock-in amplifying method was deduced firstly. Then in order to overcome the problems of great data and excessive operation brought on by this technology, a quick algorithm based on LabVIEW and a method of using external C code applied in the pick-up of photoelectric pulse wave were presented. Experimental verification was conducted in the environment of LabVIEW. The results show that by the method pres ented, the speed of operation was promoted rapidly and the data memory was reduced largely.

  2. High Sensitivity Gravity Measurements in the Adverse Environment of Oil Wells

    NASA Astrophysics Data System (ADS)

    Pfutzner, Harold

    2014-03-01

    Bulk density is a primary measurement within oil and gas reservoirs and is the basis of most reserves calculations by oil companies. The measurement is performed with a gamma-ray source and two scintillation gamma-ray detectors from within newly drilled exploration and production wells. This nuclear density measurement, while very precise is also very shallow and is therefore susceptible to errors due to any alteration of the formation and fluids in the vicinity of the borehole caused by the drilling process. Measuring acceleration due to gravity along a well provides a direct measure of bulk density with a very large depth of investigation that makes it practically immune to errors from near-borehole effects. Advances in gravity sensors and associated mechanics and electronics provide an opportunity for routine borehole gravity measurements with comparable density precision to the nuclear density measurement and with sufficient ruggedness to survive the rough handling and high temperatures experienced in oil well logging. We will describe a borehole gravity meter and its use under very realistic conditions in an oil well in Saudi Arabia. The density measurements will be presented. Alberto Marsala (2), Paul Wanjau (1), Olivier Moyal (1), and Justin Mlcak (1); (1) Schlumberger, (2) Saudi Aramco.

  3. Experimental investigation of analog and digital dimming techniques on photometric performance of an indoor Visible Light Communication (VLC) system

    NASA Astrophysics Data System (ADS)

    Zafar, Fahad; Kalavally, Vineetha; Bakaul, Masuduzzaman; Parthiban, R.

    2015-09-01

    For making commercial implementation of light emitting diode (LED) based visible light communication (VLC) systems feasible, it is necessary to incorporate it with dimming schemes which will provide energy savings, moods and increase the aesthetic value of the places using this technology. There are two general methods which are used to dim LEDs commonly categorized as analog and digital dimming. Incorporating fast data transmission with these techniques is a key challenge in VLC. In this paper, digital and analog dimming for a 10 Mb/s non return to zero on-off keying (NRZ-OOK) based VLC system is experimentally investigated considering both photometric and communicative parameters. A spectrophotometer was used for photometric analysis and a line of sight (LOS) configuration in the presence of ambient light was used for analyzing communication parameters. Based on the experimental results, it was determined that digital dimming scheme is preferable for use in indoor VLC systems requiring high dimming precision and data transmission at lower brightness levels. On the other hand, analog dimming scheme is a cost effective solution for high speed systems where dimming precision is insignificant.

  4. Three-dimensional imaging of individual point defects using selective detection angles in annular dark field scanning transmission electron microscopy.

    PubMed

    Johnson, Jared M; Im, Soohyun; Windl, Wolfgang; Hwang, Jinwoo

    2017-01-01

    We propose a new scanning transmission electron microscopy (STEM) technique that can realize the three-dimensional (3D) characterization of vacancies, lighter and heavier dopants with high precision. Using multislice STEM imaging and diffraction simulations of β-Ga 2 O 3 and SrTiO 3 , we show that selecting a small range of low scattering angles can make the contrast of the defect-containing atomic columns substantially more depth-dependent. The origin of the depth-dependence is the de-channeling of electrons due to the existence of a point defect in the atomic column, which creates extra "ripples" at low scattering angles. The highest contrast of the point defect can be achieved when the de-channeling signal is captured using the 20-40mrad detection angle range. The effect of sample thickness, crystal orientation, local strain, probe convergence angle, and experimental uncertainty to the depth-dependent contrast of the point defect will also be discussed. The proposed technique therefore opens new possibilities for highly precise 3D structural characterization of individual point defects in functional materials. Copyright © 2016 Elsevier B.V. All rights reserved.

  5. A method to enhance the measurement accuracy of Raman shift based on high precision calibration technique

    NASA Astrophysics Data System (ADS)

    Ding, Xiang; Li, Fei; Zhang, Jiyan; Liu, Wenli

    2016-10-01

    Raman spectrometers are usually calibrated periodically to ensure their measurement accuracy of Raman shift. A combination of a piece of monocrystalline silicon chip and a low pressure discharge lamp is proposed as a candidate for the reference standard of Raman shift. A high precision calibration technique is developed to accurately determine the standard value of the silicon's Raman shift around 520cm-1. The technique is described and illustrated by measuring a piece of silicon chip against three atomic spectral lines of a neon lamp. A commercial Raman spectrometer is employed and its error characteristics of Raman shift are investigated. Error sources are evaluated based on theoretical analysis and experiments, including the sample factor, the instrumental factor, the laser factor and random factors. Experimental results show that the expanded uncertainty of the silicon's Raman shift around 520cm-1 can acheive 0.3 cm-1 (k=2), which is more accurate than most of currently used reference materials. The results are validated by comparison measurement between three Raman spectrometers. It is proved that the technique can remarkably enhance the accuracy of Raman shift, making it possible to use the silicon and the lamp to calibrate Raman spectrometers.

  6. Risk assessment in the 21st century: roadmap and matrix.

    PubMed

    Embry, Michelle R; Bachman, Ammie N; Bell, David R; Boobis, Alan R; Cohen, Samuel M; Dellarco, Michael; Dewhurst, Ian C; Doerrer, Nancy G; Hines, Ronald N; Moretto, Angelo; Pastoor, Timothy P; Phillips, Richard D; Rowlands, J Craig; Tanir, Jennifer Y; Wolf, Douglas C; Doe, John E

    2014-08-01

    Abstract The RISK21 integrated evaluation strategy is a problem formulation-based exposure-driven risk assessment roadmap that takes advantage of existing information to graphically represent the intersection of exposure and toxicity data on a highly visual matrix. This paper describes in detail the process for using the roadmap and matrix. The purpose of this methodology is to optimize the use of prior information and testing resources (animals, time, facilities, and personnel) to efficiently and transparently reach a risk and/or safety determination. Based on the particular problem, exposure and toxicity data should have sufficient precision to make such a decision. Estimates of exposure and toxicity, bounded by variability and/or uncertainty, are plotted on the X- and Y-axes of the RISK21 matrix, respectively. The resulting intersection is a highly visual representation of estimated risk. Decisions can then be made to increase precision in the exposure or toxicity estimates or declare that the available information is sufficient. RISK21 represents a step forward in the goal to introduce new methodologies into 21st century risk assessment. Indeed, because of its transparent and visual process, RISK21 has the potential to widen the scope of risk communication beyond those with technical expertise.

  7. High Precision Low-blank Lithium Isotope Ratios in Forams.

    NASA Astrophysics Data System (ADS)

    Misra, S.; Froelich, P. N.

    2007-12-01

    We present a high precision (±1‰, 2σ) low blank (<500 fg/ml) method for Li isotope measurements of forams using <2 ng of Li by single collector Quad ICP-MS (Agilent 7500cs). The Li isotope ratio of seawater (δ7Li) recorded in planktonic forams has the potential to constrain the evolution of seawater chemistry and elucidate the factors driving variations of oceanic mass balances linked to the continental and sea floor/hydrothermal silica cycles. In addition a δ7Li record of seawater will complement other long-term recorders of seawater chemistry such as Sr, Os and S isotopes. Li isotope measurements of forams are limited by several factors: low Li concentrations in forams (1-2 ppm), instrument-induced fractionation and mass bias effects, matrix effects, high Li blanks and incomplete recovery of Li during column separation. Modest concentrations of alkali and alkaline earth elements in the matrix result in variable mass bias in measured Li isotope ratios. Even worse, Li strongly fractionates during chromatographic clean-up to remove Na+, Ca2+ and Mg2+, from +100‰ in the leading edge to - 100‰ in the trailing edge of elution peaks (Urey 1938). Consequently, miniscule incomplete recoveries of Li during chromatographic separations can result in large unrecognized isotope fractionation of eluents. Large mass-dependent fractionation caused by a difference of 17% in mass between 6Li and 7Li, makes Li a powerful tracer of geochemical processes, but also promotes large and difficult-to-fix isotope fractionations during laboratory chemical processing. Matrix effects of Na & Ca and of column chromatography on Li isotope ratios were investigated using artificial Li solutions representative of foram compositions (matrix matching). Li/Ca and Li/Na ratios in cleaned forams are 10 μmol/mol and 3 mmol/mol respectively. An ICP-MS tolerance limit of 20 ppb for Na and 20 μM for Ca was established, much higher tolerances than by TIMS. A single step chromatographic method to quantitatively separate Li from matrix elements using both small volume resin (3.4 meq/2ml AG50W-X8) and acid (6 ml of 0.5N HCl) was developed. Our low blank (<0.5 pg/ml) and high yield (>99.99%) column method minimizes errors in measured Li isotope ratios associated with incomplete column recovery and presence of matrix elements. High sensitivity and precision achieved with a 7500cs using cold plasma (600W), soft extraction and peak jumping coupled with very low sample to blank ratios enables high precision (±1‰, 2σ) statistically significant Li isotope measurements using very small mass of Li (0.8 ng). The development of this technique makes possible good quality Li isotope measurements from samples that are mass limited for Li, i.e., reasonable number of picked forams. This will enable us to test interferences regarding chemical cleaning and species effects in planktonic forams along the road toward creating a δ7Li record of seawater for the Cenozoic.

  8. A Decision Support System for Optimum Use of Fertilizers

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Hoskinson, Reed Louis; Hess, John Richard; Fink, Raymond Keith

    1999-07-01

    The Decision Support System for Agriculture (DSS4Ag) is an expert system being developed by the Site-Specific Technologies for Agriculture (SST4Ag) precision farming research project at the INEEL. DSS4Ag uses state-of-the-art artificial intelligence and computer science technologies to make spatially variable, site-specific, economically optimum decisions on fertilizer use. The DSS4Ag has an open architecture that allows for external input and addition of new requirements and integrates its results with existing agricultural systems’ infrastructures. The DSS4Ag reflects a paradigm shift in the information revolution in agriculture that is precision farming. We depict this information revolution in agriculture as an historic trend inmore » the agricultural decision-making process.« less

  9. A Decision Support System for Optimum Use of Fertilizers

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    R. L. Hoskinson; J. R. Hess; R. K. Fink

    1999-07-01

    The Decision Support System for Agriculture (DSS4Ag) is an expert system being developed by the Site-Specific Technologies for Agriculture (SST4Ag) precision farming research project at the INEEL. DSS4Ag uses state-of-the-art artificial intelligence and computer science technologies to make spatially variable, site-specific, economically optimum decisions on fertilizer use. The DSS4Ag has an open architecture that allows for external input and addition of new requirements and integrates its results with existing agricultural systems' infrastructures. The DSS4Ag reflects a paradigm shift in the information revolution in agriculture that is precision farming. We depict this information revolution in agriculture as an historic trend inmore » the agricultural decision-making process.« less

  10. [What kind of information do German health information pamphlets provide on mammography screening?].

    PubMed

    Kurzenhäuser, Stephanie

    2003-02-01

    To make an informed decision on participation in mammography screening, women have to be educated about all the risks and benefits of the procedure in a manner that is detailed and understandable. But an analysis of 27 German health pamphlets on mammography screening shows that many relevant pieces of information about the benefits, the risks, and especially the meaning of screening results are only insufficiently communicated. Many statements were presented narratively rather than as precise statistics. Depending on content, 17 to 62% of the quantifiable statements were actually given as numerical data. To provide comprehensive information and to avoid misunderstandings, it is necessary to supplement the currently available health pamphlets and make the information on mammography screening more precise.

  11. Space shuttle main engine definition (phase B). Volume 2: Avionics. [for space shuttle

    NASA Technical Reports Server (NTRS)

    1971-01-01

    The advent of the space shuttle engine with its requirements for high specific impulse, long life, and low cost have dictated a combustion cycle and a closed loop control system to allow the engine components to run close to operating limits. These performance requirements, combined with the necessity for low operational costs, have placed new demands on rocket engine control, system checkout, and diagnosis technology. Based on considerations of precision environment, and compatibility with vehicle interface commands, an electronic control, makes available many functions that logically provide the information required for engine system checkout and diagnosis.

  12. B-decay anomalies in Pati-Salam SU(4)

    NASA Astrophysics Data System (ADS)

    Barbieri, Riccardo; Tesi, Andrea

    2018-03-01

    Attempts to incorporate in a coherent picture the B-decay anomalies presumably observed in b→ c and b→ s semi-leptonic decays have to face the absence of signals in other related experiments, both at low and at high energies. By extending and making more precise the content of Barbieri et al. (Eur Phys J C 77(1):8, 2017), we describe one such attempt based on the Pati-Salam SU(4) group, that unifies colour and the B- L charge, in the context of a new strongly interacting sector, equally responsible for producing a pseudo-Goldstone Higgs boson.

  13. Prize for Industrial Applications of Physics Lecture: A physicist in Business

    NASA Astrophysics Data System (ADS)

    Woollam, John

    2013-03-01

    In the 1980s I inherited a famous ellipsometry laboratory. To speed up data acquisition and analysis I associated myself with creative scientists and engineers. We started a company which grew. Together we rapidly improved acquisition speed, accuracy, precision, spectral range, and types of applications. Yet, a business is much more than technology. In this talk I outline how a high-tech business functions, and illustrate the role of physicists and engineers in making a company successful. It is fast-paced, exciting, and enormously gratifying to provide quality instruments for researchers and industry.

  14. Chemical and Physical Properties of Hi-Cal-2

    NASA Technical Reports Server (NTRS)

    Spakowski, A. E.; Allen, Harrison, Jr.; Caves, Robert M.

    1955-01-01

    As part of the Navy Project Zip to consider various boron-containing materials as possible high-energy fuels, the chemical and physical properties of Hi-Cal-2 prepared by the Callery Chemical Company were evaluated at the NACA Lewis laboratory. Elemental chemical analysis, heat of combustion, vapor pressure and decomposition, freezing point, density, self ignition temperature, flash point, and blow-out velocity were determined for the fuel. Although the precision of measurement of these properties was not equal to that obtained for hydrocarbons, this special release research memorandum was prepared to make the data available as soon as possible.

  15. Automatic control system of high precision welding of workpieces in mechanical engineering

    NASA Astrophysics Data System (ADS)

    Kuznetsov, I. N.; Zvezdin, V. V.; Israfilov, I. H.; Portnov, S. M.

    2014-12-01

    In this paper, based on the conducted patent research, the system of laser welding control with different geometry of weld and shapes of parts is developed. The method of monitoring the position of the spot of laser radiation in relation to the curved weld is worked out; it is based on the tracking the edges of the welded parts by low-power laser radiation reflected from the surface of the parts. It allows to make the positioning of the focus of laser radiation in relation to the juncture of the welded parts automatically.

  16. Morphological tuning of polymeric nanoparticles via microfluidic platform for fuel cell applications.

    PubMed

    Hasani-Sadrabadi, Mohammad Mahdi; Majedi, Fatemeh Sadat; VanDersarl, Jules John; Dashtimoghadam, Erfan; Ghaffarian, S Reza; Bertsch, Arnaud; Moaddel, Homayoun; Renaud, Philippe

    2012-11-21

    At nanoscale length scales, the properties of particles change rapidly with the slightest change in dimension. The use of a microfluidic platform enables precise control of sub-100 nm organic nanoparticles (NPs) based on polybenzimidazole. Using hydrodynamic flow focusing, we can control the size and shape of the NPs, which in turn controls a number of particle material properties. The anhydrous proton-conducting nature of the prepared NPs allowed us to make a high-performance ion exchange membrane for fuel cell applications, and microfluidic tuning of the NPs allowed us subsequently to tune the fuel cell performance.

  17. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Sukhovoj, A. M., E-mail: suchovoj@nf.jinr.ru; Mitsyna, L. V., E-mail: mitsyna@nf.jinr.ru; Jovancevic, N., E-mail: nikola.jovancevic@uns.ac.rs

    The intensities of two-step cascades in 43 nuclei of mass number in the range of 28 ≤ A ≤ 200 were approximated to a high degree of precision within a modified version of the practical cascade-gammadecay model introduced earlier. In this version, the rate of the decrease in the model-dependent density of vibrational levels has the same value for any Cooper pair undergoing breakdown. The most probable values of radiative strength functions both for E1 and for M1 transitions are determined by using one or two peaks against a smooth model dependence on the gamma-transition energy. The statement that themore » thresholds for the breaking of Cooper pairs are higher for spherical than for deformed nuclei is a basic result of the respective analysis. The parameters of the cascade-decay process are now determined to a precision that makes it possible to observe the systematic distinctions between them for nuclei characterized by different parities of neutrons and protons.« less

  18. A Bitter Pill: The Cosmic Lithium Problem

    NASA Astrophysics Data System (ADS)

    Fields, Brian

    2014-03-01

    Primordial nucleosynthesis describes the production of the lightest nuclides in the first three minutes of cosmic time. We will discuss the transformative influence of the WMAP and Planck determinations of the cosmic baryon density. Coupled with nucleosynthesis theory, these measurements make tight predictions for the primordial light element abundances: deuterium observations agree spectacularly with these predictions, helium observations are in good agreement, but lithium observations (in ancient halo stars) are significantly discrepant-this is the ``lithium problem.'' Over the past decade, the lithium discrepancy has become more severe, and very recently the solution space has shrunk. A solution due to new nuclear resonances has now been essentially ruled out experimentally. Stellar evolution solutions remain viable but must be finely tuned. Observational systematics are now being probed by qualitatively new methods of lithium observation. Finally, new physics solutions are now strongly constrained by the combination of the precision baryon determination by Planck, and the need to match the D/H abundances now measured to unprecedented precision at high redshift. Supported in part by NSF grant PHY-1214082.

  19. Prospects for Precision Measurement of CO2 Column from Space

    NASA Technical Reports Server (NTRS)

    Heaps, William S.; Kawa, S. Randolph; Burris, John F.; Wilson, Emily L.; Georgieva, Elena; Miodek, Marty

    2005-01-01

    In order to address the problem of sources and sinks of CO2 measurements are needed on a global scale. Clearly a satellite is a promising approach to meeting this requirement. Unfortunately, most methods for making a CO2 measurement from space involve the whole column. Since sources and sinks at the surface represent a small perturbation to the total column one is faced with the need to measure the column with a precision better than 1%. No species has ever been measured from space at this level. We have developed over the last 3 years a small instrument based upon a Fabry-Perot interferometer that is very sensitive to atmospheric CO2 and has a high signal to noise ratio. We have tested this instrument in a ground based configuration and from aircraft platforms simulating operation from a satellite. We will present results from these tests and discuss ways that this promising new instrument could be used to improve our understanding of the global carbon budget.

  20. Mission in the works promises precise global topographic data

    USGS Publications Warehouse

    Farr, T.; Evans, D.; Zebker, H.; Harding, D.; Bufton, J.; Dixon, T.; Vetrella, S.; Gesch, D.B.

    1995-01-01

    Significant deficiencies in the quality of today's topographic data severely limit scientific applications. Very few available data sets meet the stringent requirements of 10–30 m for global digital topography and 5 m or better vertical accuracy, and existing satellite systems are unlikely to fulfill these requirements. The Joint Topographic Science Working Group, appointed by NASA and the Italian Space Agency, concluded that radar interferometry coupled with a laser altimeter would be the most promising approach for improving data quality. By providing its own illumination at a wavelength Ion g enough to (e.g., λ = 25 cm) to penetrate clouds and rain, the interferometer would provide a global, uniform high-quality topographic data set. One mission under study, TOPSAT, is well positioned to fill this niche and promises to pave the way toward a more standardized and precise topographic database. TOPSAT would be an international mission, designed to make use of recent technology advances in such programs as NASA's New Millennium. It could be ready to launch by the end of this decade.

  1. New results from RENO and prospects with RENO-50

    NASA Astrophysics Data System (ADS)

    Kim, Soo-Bong

    2015-08-01

    RENO (Reactor Experiment for Neutrino Oscillation) has made a definitive measurement of the smallest mixing angle θ13 in 2012, based on the disappearance of electron antineutrinos. More precise measurements have been obtained and presented on the mixing angle and the reactor neutrino spectrum, using ˜800 days of data. We have observed an excess of inverse-beta-decay (IBD) prompt spectrum near 5 MeV with respect to the most commonly used models. The excess is found to be consistent with coming from reactors. We have also successfully measured the reactor neutrino flux with a delayed signal of neutron capture on hydrogen. A future reactor neutrino experiment of RENO-50 is proposed to determine the neutrino mass hierarchy and to make highly precise measurements of θ12, Δm212, and Δ m312. Physics goals and sensitivities of RENO-50 are presented with a strategy of obtaining an extremely good energy resolution toward the neutrino mass hierarchy.

  2. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Alhroob, M.; Boyd, G.; Hasib, A.

    Precision ultrasonic measurements in binary gas systems provide continuous real-time monitoring of mixture composition and flow. Using custom micro-controller-based electronics, we have developed an ultrasonic instrument, with numerous potential applications, capable of making continuous high-precision sound velocity measurements. The instrument measures sound transit times along two opposite directions aligned parallel to - or obliquely crossing - the gas flow. The difference between the two measured times yields the gas flow rate while their average gives the sound velocity, which can be compared with a sound velocity vs. molar composition look-up table for the binary mixture at a given temperature andmore » pressure. The look-up table may be generated from prior measurements in known mixtures of the two components, from theoretical calculations, or from a combination of the two. We describe the instrument and its performance within numerous applications in the ATLAS experiment at the CERN Large Hadron Collider (LHC). The instrument can be of interest in other areas where continuous in-situ binary gas analysis and flowmetry are required. (authors)« less

  3. Design and Implementation of BDS RTCM SSR Message

    NASA Astrophysics Data System (ADS)

    Xiao, Xia; Cheng, Fang; Liu, Feng; Lu, XiaoChun

    2017-09-01

    Based on the real-time differential positioning system of Beidou wide area, a set of Beidou high-precision differential information transmission protocol is studied and designed. After the system generates satellite precise orbit and clock difference products, it needs to be sent to the users in a certain data format through C band GEO communication satellite. The transport protocol should be designed according to the data volume and update rate of the system. At the same time, it is necessary to combine the signal system, satellite resources and the restriction and restriction of the receiver implementation technology. It refers to the relevant fields and international similar systems of technology and standards to design. This paper establishes a set of technical indicators which can measure the pros and cons of differential message organization and broadcasting strategy. Through modeling, simulation and actual test, this paper makes a comprehensive comparison of different strategies. Finally, a transmission protocol design scheme which has good performance and meets the system service requirements is presented.

  4. Quantum-Dot Single-Photon Sources for Entanglement Enhanced Interferometry.

    PubMed

    Müller, M; Vural, H; Schneider, C; Rastelli, A; Schmidt, O G; Höfling, S; Michler, P

    2017-06-23

    Multiphoton entangled states such as "N00N states" have attracted a lot of attention because of their possible application in high-precision, quantum enhanced phase determination. So far, N00N states have been generated in spontaneous parametric down-conversion processes and by mixing quantum and classical light on a beam splitter. Here, in contrast, we demonstrate superresolving phase measurements based on two-photon N00N states generated by quantum dot single-photon sources making use of the Hong-Ou-Mandel effect on a beam splitter. By means of pulsed resonance fluorescence of a charged exciton state, we achieve, in postselection, a quantum enhanced improvement of the precision in phase uncertainty, higher than prescribed by the standard quantum limit. An analytical description of the measurement scheme is provided, reflecting requirements, capability, and restraints of single-photon emitters in optical quantum metrology. Our results point toward the realization of a real-world quantum sensor in the near future.

  5. The development of magnetic field measurement system for drift-tube linac quadrupole

    NASA Astrophysics Data System (ADS)

    Zhou, Jianxin; Kang, Wen; Yin, Baogui; Peng, Quanling; Li, Li; Liu, Huachang; Gong, Keyun; Li, Bo; Chen, Qiang; Li, Shuai; Liu, Yiqin

    2015-06-01

    In the China Spallation Neutron Source (CSNS) linac, a conventional 324 MHz drift-tube linac (DTL) accelerating an H- ion beam from 3 MeV to 80 MeV has been designed and manufactured. The electromagnetic quadrupoles (EMQs) are widely used in a DTL accelerator. The main challenge of DTLQ's structure is to house a strong gradient EMQ in the much reduced space of the drift-tube (DT). To verify the DTLQ's design specifications and fabrication quality, a precision harmonic coil measurement system has been developed, which is based on the high precision movement platform, the harmonic coil with ceramic frame and the special method to make the harmonic coil and the quadrupoles coaxial. After more than one year's continuous running, the magnetic field measurement system still performs accurately and stably. The field measurement of more than one hundred DTLQ has been finished. The components and function of the measurement system, the key point of the technology and the repeatability of the measurement results are described in this paper.

  6. MEMS-based beam-steerable free-space optical communication link for reconfigurable wireless data center

    NASA Astrophysics Data System (ADS)

    Deng, Peng; Kavehrad, Mohsen; Lou, Yan

    2017-01-01

    Flexible wireless datacenter networks based on free space optical communication (FSO) links are being considered as promising solutions to meet the future datacenter demands of high throughput, robustness to dynamic traffic patterns, cabling complexity and energy efficiency. Robust and precise steerable FSO links over dynamic traffic play a key role in the reconfigurable optical wireless datacenter inter-rack network. In this work, we propose and demonstrate a reconfigurable 10Gbps FSO system incorporated with smart beam acquisition and tracking mechanism based on gimballess two-axis MEMS micro-mirror and retro-reflective film marked aperture. The fast MEMS-based beam acquisition switches laser beam of FSO terminal from one rack to the next for reconfigurable networks, and the precise beam tracking makes FSO device auto-correct the misalignment in real-time. We evaluate the optical power loss and bit error rate performance of steerable FSO links at various directions. Experimental results suggest that the MEMS based beam steerable FSO links hold considerable promise for the future reconfigurable wireless datacenter networks.

  7. Improved cancer diagnostics by different image processing techniques on OCT images

    NASA Astrophysics Data System (ADS)

    Kanawade, Rajesh; Lengenfelder, Benjamin; Marini Menezes, Tassiana; Hohmann, Martin; Kopfinger, Stefan; Hohmann, Tim; Grabiec, Urszula; Klämpfl, Florian; Gonzales Menezes, Jean; Waldner, Maximilian; Schmidt, Michael

    2015-07-01

    Optical-coherence tomography (OCT) is a promising non-invasive, high-resolution imaging modality which can be used for cancer diagnosis and its therapeutic assessment. However, speckle noise makes detection of cancer boundaries and image segmentation problematic and unreliable. Therefore, to improve the image analysis for a precise cancer border detection, the performance of different image processing algorithms such as mean, median, hybrid median filter and rotational kernel transformation (RKT) for this task is investigated. This is done on OCT images acquired from an ex-vivo human cancerous mucosa and in vitro by using cultivated tumour applied on organotypical hippocampal slice cultures. The preliminary results confirm that the border between the healthy and the cancer lesions can be identified precisely. The obtained results are verified with fluorescence microscopy. This research can improve cancer diagnosis and the detection of borders between healthy and cancerous tissue. Thus, it could also reduce the number of biopsies required during screening endoscopy by providing better guidance to the physician.

  8. TESS Follow-up Observing Programs at the University of Wyoming

    NASA Astrophysics Data System (ADS)

    Jang-Condell, Hannah; Kasper, David; Kar, Aman; Sorber, Rebecca; Hancock, Daniel A.; Leuquire, Jacob D.; Suhaimi, Afiq; Kobulnicky, Henry A.; Pierce, Michael; Pilachowski, Catherine A.

    2018-06-01

    The Transiting Exoplanet Survey Satellite (TESS), launched in Spring 2018, will detect thousands of new exoplanet candidates. These candidates will need to be vetted by ground-based observatories to rule out false positives. The Observatories at the University of Wyoming are well-positioned to take active roles in TESS Follow-Up Observing Program (TFOP) Working Groups. The 0.6-m Red Buttes Observatory has already demonstrated its capability to do precision photometric monitoring of transiting exoplanet targets as a participant in the Kilodegree Extremely Little Telescope Follow-Up Network (KELT-FUN). A new echelle spectrograph, Fiber High-Resolution Echelle (FHiRE), being built for the 2.3-m Wyoming InfraRed Observatory (WIRO), will enable precision radial velocity measurements of exoplanet candidates. Over 180 nights/year at both observatories will be available to our team to undertake follow-up observations of TESS Objects of Interest (TOIs). We anticipate making significant contributions to new exoplanet discoveries in the era of TESS.

  9. Prenatal diagnosis in a cystic fibrosis family: a combined molecular strategy for a precise diagnosis.

    PubMed

    Chávez-Saldaña, Margarita; García-Cavazos, Ricardo; Vigueras, Rosa María; Orozco, Lorena

    2011-01-01

    The high genetic heterogeneity in populations with a wide spectrum of mutations in the CF transmembrane conductance regulator gene (CFTR), makes the detection of mutations a very hard and difficult task, thereby limiting the accurate diagnosis of the disease, mainly in patients with uncharacterized mutations. Molecular strategies, like targeted identification of the most frequent CFTR mutations in Mexican population combined with linkage analysis using markers, is very useful for carrier detection and for prenatal diagnosis in affected families with CF. In this paper we show that the combination of methodologies was a crucial alternative to reach a precise prenatal CF diagnosis. We documented CF diagnosis in a 14th-week fetus combining the screening of the most common mutations in Mexican population with linkage analysis of two extragenic polymorphisms (XV2C/TaqI and KM19/PstI). We determined that the fetus inherited the PG542X mutation from its mother and an unknown mutation from its father through the chromosomal phases analysis.

  10. Laser Atmospheric Transmitter Receiver-Network (LAnTeRN): A new approach for active measurement of atmospheric greenhouse gases

    NASA Astrophysics Data System (ADS)

    Dobler, J. T.; Braun, M.; Zaccheo, T.

    2012-12-01

    The Laser Atmospheric Transmitter Receiver-Network (LAnTeRN) is a new measurement concept that will enable local, regional and continental determination of key greenhouse gases, with unparalleled accuracy and precision. This new approach will offer the ability to make low bias, high precision, quasi-continuous, measurements to the accuracies required for separating anthropogenic and biogenic sources and sinks. In 2004 ITT Exelis developed an airborne demonstration unit, based on an intensity modulated continuous wave (IM-CW) lidar approach, for actively measuring atmospheric CO2 and O2. The multi-functional fiber laser lidar (MFLL) system relies on low peak power, high reliability, and efficient telecom laser components to implement this unique measurement approach. While evaluating methods for discriminating against thin clouds for the MFLL instrument, a new measurement concept was conceived. LAnTeRN has several fundamental characteristics in common with the MFLL instrument, but is a fundamentally different implementation and capability. The key difference is that LAnTeRN operates in transmission rather than in the traditional backscatter lidar configuration, which has several distinct advantages. Operating as a forward scatter, bistatic lidar system, LAnTeRN enables consideration of continuous monitoring from a geostationary orbit to multiple locations on the ground. Having the receivers on the ground significantly lowers cost and risk compared to an all space based mission, and allows the transmitter subsystem to be implemented, near term, as a hosted payload. Furthermore, the LAnTeRN measurement approach is also applicable for ground to ground measurements where high precision measurements over a long open path is required, such as facilities monitoring, or monitoring of passive volcanoes and fault lines. Using narrow linewidth laser sources allows flexibility to select the position on the absorption feature being probed. This feature allows for weighting the absorption toward lower altitudes for the space implementation or to handle large dynamic range measurements as would be required for volcano monitoring. This presentation will discuss results from a detailed instrument performance analyses, retrieval simulations, and from initial testing of a proof of concept demonstration unit being developed by Exelis. Initial analysis indicate that measurements from a transmitter in geostationary orbit to 25 ground receivers in the eastern U.S. can retrieve column integrated CO2 values to a precision of <0.2 ppm on monthly averages and <0.06 ppm on yearly averages, using conservative estimates of cloud cover and aerosol loading. The capability for continuous monitoring over a fixed geometry makes it possible to independently characterize the atmospheric column, using existing capabilities (e.g. aircore, aircraft and in-situ instrumentation), for quantification of bias. Furthermore, the ability to selectively locate the ground receivers can enable focused studies for specific applications.

  11. Potassium Stable Isotopic Compositions Measured by High-Resolution MC-ICP-MS

    NASA Technical Reports Server (NTRS)

    Morgan, Leah E.; Lloyd, Nicholas S.; Ellam, Robert M.; Simon, Justin I.

    2012-01-01

    Potassium isotopic (K-41/K-39) compositions are notoriously difficult to measure. TIMS measurements are hindered by variable fractionation patterns throughout individual runs and too few isotopes to apply an internal spike method for instrumental mass fractionation corrections. Internal fractionation corrections via the K-40/K-39 ratio can provide precise values but assume identical K-40/K-39 ratios (e.g. 0.05% (1sigma) in [1]); this is appropriate in some cases (e.g. identifying excess K-41) but not others (e.g., determining mass fractionation effects and metrologically traceable isotopic abundances). SIMS analyses have yielded measurements with 0.25% precisions (1sigma) [2]. ICP-MS analyses are significantly affected by interferences from molecular species such as Ar-38H(+) and Ar-40H(+) and instrument mass bias. Single collector ICP-MS instruments in "cold plasma" mode have yielded uncertainties as low as 2% (1sigma, e.g. [3]). Although these precisions may be acceptable for some concentration determinations, they do not resolve isotopic variation in terrestrial materials. Here we present data from a series of measurements made on the Thermo Scientific NEPTUNE Plus multi-collector ICP-MS that demonstrate the ability to make K-41/K-39 ratio measurements with 0.07% precisions (1sigma). These data, collected on NIST K standards, indicate the potential for MC-ICP-MS measurements to look for K isotopic variations at the sub-permil level. The NEPTUNE Plus can sufficiently resolve 39K and 41K from the interfering 38ArH+ and 40ArH+ peaks in wet cold plasma and high-resolution mode. Measurements were made on small but flat, interference-free, plateaus (ca. 50 ppm by mass width for K-41). Although ICP-MS does not yield accurate K-41/K-39 values due to significant instrumental mass fractionation (ca. 6%), this bias can be sufficiently stable over the time required for several measurements so that relative K-41/K-39 values can be precisely determined via sample-standard bracketing. As cold plasma conditions can amplify matrix effects, experiments were conducted to test the matrix tolerance of measurements; the use of clean, matrix-matched samples and standards is critical. Limitations of the cold-plasma high-resolution MC-ICP-MS methodology with respect to matrix tolerance are discussed and compared with the limitations of TIMS methodologies.

  12. Mass spectrometric measurements of the isotopic anatomies of molecules (Invited)

    NASA Astrophysics Data System (ADS)

    Eiler, J. M.; Krumwiede, D.; Schlueter, H.

    2013-12-01

    Site-specific and multiple isotopic substitutions in molecular structures potentially provide an extraordinarily rich set of constraints on their sources, conditions of formation, reaction and transport histories, and perhaps other issues. Examples include carbonate ';clumped isotope' thermometry, clumped isotope measurements of CO2, O2, and, recently, methane, ethane and N2O; site-specific 15N measurements in N2O and 13C and D analyses of fatty acids, sugars, cellulose, food products, and, recently, n-alkanes. Extension of the principles behind these tools to the very large number of isotopologues of complex molecules could potentially lead to new uses of isotope chemistry, similar to proteomics, metabolomics and genomics in their complexity and depth of detail (';isotomics'?). Several technologies are potentially useful for this field, including ';SNIF-NMR', gas source mass spectrometry and IR absorption spectroscopy. However, all well established methods have restrictive limits in the sizes of samples, types of analyzes, and the sorts of isotopologues that can be measured with useful precision. We will present an overview of several emerging instruments and techniques of high-resolution gas source mass spectrometry that may enable study of a large proportion of the isotopologues of a wide range of volatile and semi-volatile compounds, including many organics, with precisions and sample sizes suitable for a range of applications. A variety of isotopologues can be measured by combining information from the Thermo 253 Ultra (a new high resolution, multi-collector gas source mass spectrometer) and the Thermo DFS (a very high resolution single collector, but used here on a novel mode to achieve ~per mil precision ratio measurements), sometimes supplemented by conventional bulk isotopic measurements. It is possible to design methods in which no one of these sources of data meaningfully constrain abundances of specific isotopologues, but their combination fully and precisely constrains a large number. We have assembled a suite of instruments (including the prototype of the Ultra, and a modified version of the DFS that is capable of dual inlet analyses) that make it logistically straightforward to perform such multi-instrument analyses. Examples will be presented documenting the accuracy of these techniques for systems that are independently well known (e.g., isotopologues of methane), and the precision and internal consistency of results for larger, more complex molecules (e.g., a suite of singly and doubly substituted isotopologues of hexane and other moderate-molecular-weight organics).

  13. High precision locating control system based on VCM for Talbot lithography

    NASA Astrophysics Data System (ADS)

    Yao, Jingwei; Zhao, Lixin; Deng, Qian; Hu, Song

    2016-10-01

    Aiming at the high precision and efficiency requirements of Z-direction locating in Talbot lithography, a control system based on Voice Coil Motor (VCM) was designed. In this paper, we built a math model of VCM and its moving characteristic was analyzed. A double-closed loop control strategy including position loop and current loop were accomplished. The current loop was implemented by driver, in order to achieve the rapid follow of the system current. The position loop was completed by the digital signal processor (DSP) and the position feedback was achieved by high precision linear scales. Feed forward control and position feedback Proportion Integration Differentiation (PID) control were applied in order to compensate for dynamic lag and improve the response speed of the system. And the high precision and efficiency of the system were verified by simulation and experiments. The results demonstrated that the performance of Z-direction gantry was obviously improved, having high precision, quick responses, strong real-time and easily to expend for higher precision.

  14. CPU time optimization and precise adjustment of the Geant4 physics parameters for a VARIAN 2100 C/D gamma radiotherapy linear accelerator simulation using GAMOS.

    PubMed

    Arce, Pedro; Lagares, Juan Ignacio

    2018-01-25

    We have verified the GAMOS/Geant4 simulation model of a 6 MV VARIAN Clinac 2100 C/D linear accelerator by the procedure of adjusting the initial beam parameters to fit the percentage depth dose and cross-profile dose experimental data at different depths in a water phantom. Thanks to the use of a wide range of field sizes, from 2  ×  2 cm 2 to 40  ×  40 cm 2 , a small phantom voxel size and high statistics, fine precision in the determination of the beam parameters has been achieved. This precision has allowed us to make a thorough study of the different physics models and parameters that Geant4 offers. The three Geant4 electromagnetic physics sets of models, i.e. Standard, Livermore and Penelope, have been compared to the experiment, testing the four different models of angular bremsstrahlung distributions as well as the three available multiple-scattering models, and optimizing the most relevant Geant4 electromagnetic physics parameters. Before the fitting, a comprehensive CPU time optimization has been done, using several of the Geant4 efficiency improvement techniques plus a few more developed in GAMOS.

  15. Validation of the sperm class analyser CASA system for sperm counting in a busy diagnostic semen analysis laboratory.

    PubMed

    Dearing, Chey G; Kilburn, Sally; Lindsay, Kevin S

    2014-03-01

    Sperm counts have been linked to several fertility outcomes making them an essential parameter of semen analysis. It has become increasingly recognised that Computer-Assisted Semen Analysis (CASA) provides improved precision over manual methods but that systems are seldom validated robustly for use. The objective of this study was to gather the evidence to validate or reject the Sperm Class Analyser (SCA) as a tool for routine sperm counting in a busy laboratory setting. The criteria examined were comparison with the Improved Neubauer and Leja 20-μm chambers, within and between field precision, sperm concentration linearity from a stock diluted in semen and media, accuracy against internal and external quality material, assessment of uneven flow effects and a receiver operating characteristic (ROC) analysis to predict fertility in comparison with the Neubauer method. This work demonstrates that SCA CASA technology is not a standalone 'black box', but rather a tool for well-trained staff that allows rapid, high-number sperm counting providing errors are identified and corrected. The system will produce accurate, linear, precise results, with less analytical variance than manual methods that correlate well against the Improved Neubauer chamber. The system provides superior predictive potential for diagnosing fertility problems.

  16. Design of a self-adaptive fuzzy PID controller for piezoelectric ceramics micro-displacement system

    NASA Astrophysics Data System (ADS)

    Zhang, Shuang; Zhong, Yuning; Xu, Zhongbao

    2008-12-01

    In order to improve control precision of the piezoelectric ceramics (PZT) micro-displacement system, a self-adaptive fuzzy Proportional Integration Differential (PID) controller is designed based on the traditional digital PID controller combining with fuzzy control. The arithmetic gives a fuzzy control rule table with the fuzzy control rule and fuzzy reasoning, through this table, the PID parameters can be adjusted online in real time control. Furthermore, the automatic selective control is achieved according to the change of the error. The controller combines the good dynamic capability of the fuzzy control and the high stable precision of the PID control, adopts the method of using fuzzy control and PID control in different segments of time. In the initial and middle stage of the transition process of system, that is, when the error is larger than the value, fuzzy control is used to adjust control variable. It makes full use of the fast response of the fuzzy control. And when the error is smaller than the value, the system is about to be in the steady state, PID control is adopted to eliminate static error. The problems of PZT existing in the field of precise positioning are overcome. The results of the experiments prove that the project is correct and practicable.

  17. The Dopaminergic Midbrain Encodes the Expected Certainty about Desired Outcomes.

    PubMed

    Schwartenbeck, Philipp; FitzGerald, Thomas H B; Mathys, Christoph; Dolan, Ray; Friston, Karl

    2015-10-01

    Dopamine plays a key role in learning; however, its exact function in decision making and choice remains unclear. Recently, we proposed a generic model based on active (Bayesian) inference wherein dopamine encodes the precision of beliefs about optimal policies. Put simply, dopamine discharges reflect the confidence that a chosen policy will lead to desired outcomes. We designed a novel task to test this hypothesis, where subjects played a "limited offer" game in a functional magnetic resonance imaging experiment. Subjects had to decide how long to wait for a high offer before accepting a low offer, with the risk of losing everything if they waited too long. Bayesian model comparison showed that behavior strongly supported active inference, based on surprise minimization, over classical utility maximization schemes. Furthermore, midbrain activity, encompassing dopamine projection neurons, was accurately predicted by trial-by-trial variations in model-based estimates of precision. Our findings demonstrate that human subjects infer both optimal policies and the precision of those inferences, and thus support the notion that humans perform hierarchical probabilistic Bayesian inference. In other words, subjects have to infer both what they should do as well as how confident they are in their choices, where confidence may be encoded by dopaminergic firing. © The Author 2014. Published by Oxford University Press.

  18. The Dopaminergic Midbrain Encodes the Expected Certainty about Desired Outcomes

    PubMed Central

    Schwartenbeck, Philipp; FitzGerald, Thomas H. B.; Mathys, Christoph; Dolan, Ray; Friston, Karl

    2015-01-01

    Dopamine plays a key role in learning; however, its exact function in decision making and choice remains unclear. Recently, we proposed a generic model based on active (Bayesian) inference wherein dopamine encodes the precision of beliefs about optimal policies. Put simply, dopamine discharges reflect the confidence that a chosen policy will lead to desired outcomes. We designed a novel task to test this hypothesis, where subjects played a “limited offer” game in a functional magnetic resonance imaging experiment. Subjects had to decide how long to wait for a high offer before accepting a low offer, with the risk of losing everything if they waited too long. Bayesian model comparison showed that behavior strongly supported active inference, based on surprise minimization, over classical utility maximization schemes. Furthermore, midbrain activity, encompassing dopamine projection neurons, was accurately predicted by trial-by-trial variations in model-based estimates of precision. Our findings demonstrate that human subjects infer both optimal policies and the precision of those inferences, and thus support the notion that humans perform hierarchical probabilistic Bayesian inference. In other words, subjects have to infer both what they should do as well as how confident they are in their choices, where confidence may be encoded by dopaminergic firing. PMID:25056572

  19. Heliostat kinematic system calibration using uncalibrated cameras

    NASA Astrophysics Data System (ADS)

    Burisch, Michael; Gomez, Luis; Olasolo, David; Villasante, Cristobal

    2017-06-01

    The efficiency of the solar field greatly depends on the ability of the heliostats to precisely reflect solar radiation onto a central receiver. To control the heliostats with such a precision accurate knowledge of the motion of each of them modeled as a kinematic system is required. Determining the parameters of this system for each heliostat by a calibration system is crucial for the efficient operation of the solar field. For small sized heliostats being able to make such a calibration in a fast and automatic manner is imperative as the solar field potentially contain tens or even hundreds of thousands of them. A calibration system which can rapidly recalibrate a whole solar field would also allow reducing costs. Heliostats are generally designed to provide stability over a large period of time. Being able to relax this requirement and compensate any occurring error by adapting parameters in a model, the costs of the heliostat can be reduced. The presented method describes such an automatic calibration system using uncalibrated cameras rigidly attached to each heliostat. The cameras are used to observe targets spread out through the solar field; based on this the kinematic system of the heliostat can be estimated with high precision. A comparison of this approach to similar solutions shows the viability of the proposed solution.

  20. Optimetrics for Precise Navigation

    NASA Technical Reports Server (NTRS)

    Yang, Guangning; Heckler, Gregory; Gramling, Cheryl

    2017-01-01

    Optimetrics for Precise Navigation will be implemented on existing optical communication links. The ranging and Doppler measurements are conducted over communication data frame and clock. The measurement accuracy is two orders of magnitude better than TDRSS. It also has other advantages of: The high optical carrier frequency enables: (1) Immunity from ionosphere and interplanetary Plasma noise floor, which is a performance limitation for RF tracking; and (2) High antenna gain reduces terminal size and volume, enables high precision tracking in Cubesat, and in deep space smallsat. High Optical Pointing Precision provides: (a) spacecraft orientation, (b) Minimal additional hardware to implement Precise Optimetrics over optical comm link; and (c) Continuous optical carrier phase measurement will enable the system presented here to accept future optical frequency standard with much higher clock accuracy.

  1. Motivational salience signal in the basal forebrain is coupled with faster and more precise decision speed.

    PubMed

    Avila, Irene; Lin, Shih-Chieh

    2014-03-01

    The survival of animals depends critically on prioritizing responses to motivationally salient stimuli. While it is generally believed that motivational salience increases decision speed, the quantitative relationship between motivational salience and decision speed, measured by reaction time (RT), remains unclear. Here we show that the neural correlate of motivational salience in the basal forebrain (BF), defined independently of RT, is coupled with faster and also more precise decision speed. In rats performing a reward-biased simple RT task, motivational salience was encoded by BF bursting response that occurred before RT. We found that faster RTs were tightly coupled with stronger BF motivational salience signals. Furthermore, the fraction of RT variability reflecting the contribution of intrinsic noise in the decision-making process was actively suppressed in faster RT distributions with stronger BF motivational salience signals. Artificially augmenting the BF motivational salience signal via electrical stimulation led to faster and more precise RTs and supports a causal relationship. Together, these results not only describe for the first time, to our knowledge, the quantitative relationship between motivational salience and faster decision speed, they also reveal the quantitative coupling relationship between motivational salience and more precise RT. Our results further establish the existence of an early and previously unrecognized step in the decision-making process that determines both the RT speed and variability of the entire decision-making process and suggest that this novel decision step is dictated largely by the BF motivational salience signal. Finally, our study raises the hypothesis that the dysregulation of decision speed in conditions such as depression, schizophrenia, and cognitive aging may result from the functional impairment of the motivational salience signal encoded by the poorly understood noncholinergic BF neurons.

  2. Motivational Salience Signal in the Basal Forebrain Is Coupled with Faster and More Precise Decision Speed

    PubMed Central

    Avila, Irene; Lin, Shih-Chieh

    2014-01-01

    The survival of animals depends critically on prioritizing responses to motivationally salient stimuli. While it is generally believed that motivational salience increases decision speed, the quantitative relationship between motivational salience and decision speed, measured by reaction time (RT), remains unclear. Here we show that the neural correlate of motivational salience in the basal forebrain (BF), defined independently of RT, is coupled with faster and also more precise decision speed. In rats performing a reward-biased simple RT task, motivational salience was encoded by BF bursting response that occurred before RT. We found that faster RTs were tightly coupled with stronger BF motivational salience signals. Furthermore, the fraction of RT variability reflecting the contribution of intrinsic noise in the decision-making process was actively suppressed in faster RT distributions with stronger BF motivational salience signals. Artificially augmenting the BF motivational salience signal via electrical stimulation led to faster and more precise RTs and supports a causal relationship. Together, these results not only describe for the first time, to our knowledge, the quantitative relationship between motivational salience and faster decision speed, they also reveal the quantitative coupling relationship between motivational salience and more precise RT. Our results further establish the existence of an early and previously unrecognized step in the decision-making process that determines both the RT speed and variability of the entire decision-making process and suggest that this novel decision step is dictated largely by the BF motivational salience signal. Finally, our study raises the hypothesis that the dysregulation of decision speed in conditions such as depression, schizophrenia, and cognitive aging may result from the functional impairment of the motivational salience signal encoded by the poorly understood noncholinergic BF neurons. PMID:24642480

  3. TAPIR, a web server for the prediction of plant microRNA targets, including target mimics.

    PubMed

    Bonnet, Eric; He, Ying; Billiau, Kenny; Van de Peer, Yves

    2010-06-15

    We present a new web server called TAPIR, designed for the prediction of plant microRNA targets. The server offers the possibility to search for plant miRNA targets using a fast and a precise algorithm. The precise option is much slower but guarantees to find less perfectly paired miRNA-target duplexes. Furthermore, the precise option allows the prediction of target mimics, which are characterized by a miRNA-target duplex having a large loop, making them undetectable by traditional tools. The TAPIR web server can be accessed at: http://bioinformatics.psb.ugent.be/webtools/tapir. Supplementary data are available at Bioinformatics online.

  4. Precise measurement of surface plasmon forces at a metal-dielectric interface using a calibrated evanescent wave

    NASA Astrophysics Data System (ADS)

    Liu, Lulu; Woolf, Alex

    2015-03-01

    By observing the motion of an optically trapped microscopic colloid, sub-piconewton static and dynamical forces have been measured using a technique called photonic force microscopy. This technique, though potentially powerful, has in the past struggled to make precise measurements in the vicinity of a reflective or metallic interface, due to distortions of the optical field. We introduce a new in-situ, contact-free calibration method for particle tracking using an evanescent wave, and demonstrate its expanded capability by the precise measurement of forces of interaction between a single colloid and the optical field generated by a propagating surface plasmon polariton on gold.

  5. Lightweight and High-Resolution Single Crystal Silicon Optics for X-ray Astronomy

    NASA Technical Reports Server (NTRS)

    Zhang, William W.; Biskach, Michael P.; Chan, Kai-Wing; Mazzarella, James R.; McClelland, Ryan S.; Riveros, Raul E.; Saha, Timo T.; Solly, Peter M.

    2016-01-01

    We describe an approach to building mirror assemblies for next generation X-ray telescopes. It incorporates knowledge and lessons learned from building existing telescopes, including Chandra, XMM-Newton, Suzaku, and NuSTAR, as well as from our direct experience of the last 15 years developing mirror technology for the Constellation-X and International X-ray Observatory mission concepts. This approach combines single crystal silicon and precision polishing, thus has the potential of achieving the highest possible angular resolution with the least possible mass. Moreover, it is simple, consisting of several technical elements that can be developed independently in parallel. Lastly, it is highly amenable to mass production, therefore enabling the making of telescopes of very large photon collecting areas.

  6. Towards future high performance computing: What will change? How can we be efficient?

    NASA Astrophysics Data System (ADS)

    Düben, Peter

    2017-04-01

    How can we make the most out of "exascale" supercomputers that will be available soon and enable us to calculate an amazing number of 1,000,000,000,000,000,000 real numbers operations within a single second? How do we need to design applications to use these machines efficiently? What are the limits? We will discuss opportunities and limits of the use of future high performance computers from the perspective of Earth System Modelling. We will provide an overview about future challenges and outline how numerical application will need to be changed to run efficiently on supercomputers in the future. We will also discuss how different disciplines can support each other and talk about data handling and numerical precision of data.

  7. High-sensitivity gas-mapping 3D imager and method of operation

    DOEpatents

    Kreitinger, Aaron; Thorpe, Michael

    2018-05-15

    Measurement apparatuses and methods are disclosed for generating high-precision and -accuracy gas concentration maps that can be overlaid with 3D topographic images by rapidly scanning one or several modulated laser beams with a spatially-encoded transmitter over a scene to build-up imagery. Independent measurements of the topographic target distance and path-integrated gas concentration are combined to yield a map of the path-averaged concentration between the sensor and each point in the image. This type of image is particularly useful for finding localized regions of elevated (or anomalous) gas concentration making it ideal for large-area leak detection and quantification applications including: oil and gas pipeline monitoring, chemical processing facility monitoring, and environmental monitoring.

  8. Study on manufacturing method of optical surface with high precision in angle and surface

    NASA Astrophysics Data System (ADS)

    Yu, Xin; Li, Xin; Yu, Ze; Zhao, Bin; Zhang, Xuebin; Sun, Lipeng; Tong, Yi

    2016-10-01

    This paper studied a manufacturing processing of optical surface with high precision in angel and surface. By theoretical analysis of the relationships between the angel precision and surface, the measurement conversion of the technical indicators, optical-cement method application, the optical-cement tooling design, the experiment has been finished successfully, the processing method has been verified, which can be also used in the manufacturing of the optical surface with similar high precision in angle and surface.

  9. Method of high precision interval measurement in pulse laser ranging system

    NASA Astrophysics Data System (ADS)

    Wang, Zhen; Lv, Xin-yuan; Mao, Jin-jin; Liu, Wei; Yang, Dong

    2013-09-01

    Laser ranging is suitable for laser system, for it has the advantage of high measuring precision, fast measuring speed,no cooperative targets and strong resistance to electromagnetic interference,the measuremen of laser ranging is the key paremeters affecting the performance of the whole system.The precision of the pulsed laser ranging system was decided by the precision of the time interval measurement, the principle structure of laser ranging system was introduced, and a method of high precision time interval measurement in pulse laser ranging system was established in this paper.Based on the analysis of the factors which affected the precision of range measure,the pulse rising edges discriminator was adopted to produce timing mark for the start-stop time discrimination,and the TDC-GP2 high precision interval measurement system based on TMS320F2812 DSP was designed to improve the measurement precision.Experimental results indicate that the time interval measurement method in this paper can obtain higher range accuracy. Compared with the traditional time interval measurement system,the method simplifies the system design and reduce the influence of bad weather conditions,furthermore,it satisfies the requirements of low costs and miniaturization.

  10. Extension of Fong and Alvarez: When is a lower limit of detection low enough

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Potter, W.E.

    1999-11-01

    The work of Fong and Alvarez is easily extended for counting when varied counting is not employed. It remains true in the general case that the precision of a counting method can be no less than about 30% at the LLD and so it is desirable to have decision levels at least several times larger than the LLD so that measurements have sufficient precision to make valid decisions.

  11. Extension of Fong and Alvarez: When is a lower limit of detection low enough?

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Potter, W.E.

    1999-11-01

    The work of Fong and Alvarez is easily extended for counting when varied counting is not employed. It remains true in the general case that the precision of a counting method can be no less than about 30% at the LLD and so it is desirable to have decision levels at least several times larger than the LLD so that measurements have sufficient precision to make valid decisions.

  12. Infrared Photometry for Automated Telescopes: Passband Selection

    NASA Astrophysics Data System (ADS)

    Milone, Gene; Young, Andrew T.

    2011-03-01

    The high precision that photometry in the near and intermediate infrared region can provide has not been achieved, partly because of technical challenges (including cryogenics, which most IR detectors require), and partly because the filters in common use are not optimized to avoid water-vapor absorptions, which are the principal impediment to precise ground-based IR photometry. We review the IRWG filters that achieve this goal, and the trials that were undertaken to demonstrate their superiority. We focus especially on the near IR set and, for high elevation sites, the passbands in the N window. We also discuss the price to be paid for the improved precision, in the form of lower throughput, and why it should be paid: to achieve not only higher precision (i.e., improved signal-to-noise ratio), but also lower extinction, thus producing higher accuracy in extra-atmospheric magnitudes. The edges of the IRWG passbands are not defined by the edges of the atmospheric windows: therefore, they admit no flux from these (constantly varying) edges. The throughput cost and the lack of a large body of data already obtained in these passbands are principal reasons why the IRWG filters are not in wide use at observatories around the world that currently do IR work. Yet a measure of the signal-to-noise ratio varies inversely with both extinction and with a measure of the Forbes effect. So, the small loss of raw throughput is recouped in signal-to-noise gain. We illustrate these points with passbands of both near and intermediate IR passbands. There is also the matter of cost for small production runs of these filters; reduced costs can be realized through bulk orders with uniform filter specifications. As a consequence, the near-IR IRWG passbands offer the prospect of being able to do photometry in those passbands at both high and low elevation sites that are capable of supporting precise photometry, thereby freeing infrared photometry from the need to access exclusively high and dry elevation sites, although photometry done at those sites can also benefit from improved accuracy and transformability. We suggest that if the IRWG passbands are made available, they will be used! New automated systems making use of these passbands have the advantage of establishing the system more widely, creating a larger body of data to which future observations will be fully transformable, and will be cheaper to purchase. This work has been supported in part by grants to EFM by the Canadian Natural Sciences and Engineering Research Council.

  13. Precision medicine in cardiology.

    PubMed

    Antman, Elliott M; Loscalzo, Joseph

    2016-10-01

    The cardiovascular research and clinical communities are ideally positioned to address the epidemic of noncommunicable causes of death, as well as advance our understanding of human health and disease, through the development and implementation of precision medicine. New tools will be needed for describing the cardiovascular health status of individuals and populations, including 'omic' data, exposome and social determinants of health, the microbiome, behaviours and motivations, patient-generated data, and the array of data in electronic medical records. Cardiovascular specialists can build on their experience and use precision medicine to facilitate discovery science and improve the efficiency of clinical research, with the goal of providing more precise information to improve the health of individuals and populations. Overcoming the barriers to implementing precision medicine will require addressing a range of technical and sociopolitical issues. Health care under precision medicine will become a more integrated, dynamic system, in which patients are no longer a passive entity on whom measurements are made, but instead are central stakeholders who contribute data and participate actively in shared decision-making. Many traditionally defined diseases have common mechanisms; therefore, elimination of a siloed approach to medicine will ultimately pave the path to the creation of a universal precision medicine environment.

  14. Chopping Copy.

    ERIC Educational Resources Information Center

    Bush, Don

    1994-01-01

    Discusses ways an editor can cut out words to help the reader understand quickly. Discusses dead wood, redundancy, redundancy in thought, smothered verbs, false precision, editing and academia, and making copy smoother. (SR)

  15. A farm-level precision land management framework based on integer programming

    PubMed Central

    Li, Qi; Hu, Guiping; Jubery, Talukder Zaki; Ganapathysubramanian, Baskar

    2017-01-01

    Farmland management involves several planning and decision making tasks including seed selection and irrigation management. A farm-level precision farmland management model based on mixed integer linear programming is proposed in this study. Optimal decisions are designed for pre-season planning of crops and irrigation water allocation. The model captures the effect of size and shape of decision scale as well as special irrigation patterns. The authors illustrate the model with a case study on a farm in the state of California in the U.S. and show the model can capture the impact of precision farm management on profitability. The results show that threefold increase of annual net profit for farmers could be achieved by carefully choosing irrigation and seed selection. Although farmers could increase profits by applying precision management to seed or irrigation alone, profit increase is more significant if farmers apply precision management on seed and irrigation simultaneously. The proposed model can also serve as a risk analysis tool for farmers facing seasonal irrigation water limits as well as a quantitative tool to explore the impact of precision agriculture. PMID:28346499

  16. Environmental applications of single collector high resolution ICP-MS.

    PubMed

    Krachler, Michael

    2007-08-01

    The number of environmental applications of single collector high resolution ICP-MS (HR-ICP-MS) has increased rapidly in recent years. There are many factors that contribute to make HR-ICP-MS a very powerful tool in environmental analysis. They include the extremely low detection limits achievable, tremendously high sensitivity, the ability to separate ICP-MS signals of the analyte from spectral interferences, enabling the reliable determination of many trace elements, and the reasonable precision of isotope ratio measurements. These assets are improved even further using high efficiency sample introduction systems. Therefore, external factors such as the stability of laboratory blanks are frequently the limiting factor in HR-ICP-MS analysis rather than the detection power. This review aims to highlight the most recent applications of HR-ICP-MS in this sector, focusing on matrices and applications where the superior capabilities of the instrumental technique are most useful and often ultimately required.

  17. A Predictive Algorithm to Detect Opioid Use Disorder

    PubMed Central

    Lee, Chee; Sharma, Maneesh; Kantorovich, Svetlana

    2018-01-01

    Purpose: The purpose of this study was to determine the clinical utility of an algorithm-based decision tool designed to assess risk associated with opioid use in the primary care setting. Methods: A prospective, longitudinal study was conducted to assess the utility of precision medicine testing in 1822 patients across 18 family medicine/primary care clinics in the United States. Using the profile, patients were categorized into low, moderate, and high risk for opioid use. Physicians who ordered testing were asked to complete patient evaluations and document their actions, decisions, and perceptions regarding the utility of the precision medicine tests. Results: Approximately 47% of primary care physicians surveyed used the profile to guide clinical decision-making. These physicians rated the benefit of the profile on patient care an average of 3.6 on a 5-point scale (1 indicating no benefit and 5 indicating significant benefit). Eighty-eight percent of all clinicians surveyed felt the test exhibited some benefit to their patient care. The most frequent utilization for the profile was to guide a change in opioid prescribed. Physicians reported greater benefit of profile utilization for minority patients. Patients whose treatment was guided by the profile had pain levels that were reduced, on average, 2.7 levels on the numeric rating scale. Conclusions: The profile provided primary care physicians with a useful tool to stratify the risk of opioid use disorder and was rated as beneficial for decision-making and patient improvement by the majority of physicians surveyed. Physicians reported the profile resulted in greater clinical improvement for minorities, highlighting the objective use of this profile to guide judicial use of opioids in high-risk patients. Significantly, when physicians used the profile to guide treatment decisions, patient-reported pain was greatly reduced. PMID:29383324

  18. A Predictive Algorithm to Detect Opioid Use Disorder: What Is the Utility in a Primary Care Setting?

    PubMed

    Lee, Chee; Sharma, Maneesh; Kantorovich, Svetlana; Brenton, Ashley

    2018-01-01

    The purpose of this study was to determine the clinical utility of an algorithm-based decision tool designed to assess risk associated with opioid use in the primary care setting. A prospective, longitudinal study was conducted to assess the utility of precision medicine testing in 1822 patients across 18 family medicine/primary care clinics in the United States. Using the profile, patients were categorized into low, moderate, and high risk for opioid use. Physicians who ordered testing were asked to complete patient evaluations and document their actions, decisions, and perceptions regarding the utility of the precision medicine tests. Approximately 47% of primary care physicians surveyed used the profile to guide clinical decision-making. These physicians rated the benefit of the profile on patient care an average of 3.6 on a 5-point scale (1 indicating no benefit and 5 indicating significant benefit). Eighty-eight percent of all clinicians surveyed felt the test exhibited some benefit to their patient care. The most frequent utilization for the profile was to guide a change in opioid prescribed. Physicians reported greater benefit of profile utilization for minority patients. Patients whose treatment was guided by the profile had pain levels that were reduced, on average, 2.7 levels on the numeric rating scale. The profile provided primary care physicians with a useful tool to stratify the risk of opioid use disorder and was rated as beneficial for decision-making and patient improvement by the majority of physicians surveyed. Physicians reported the profile resulted in greater clinical improvement for minorities, highlighting the objective use of this profile to guide judicial use of opioids in high-risk patients. Significantly, when physicians used the profile to guide treatment decisions, patient-reported pain was greatly reduced.

  19. The Foundation Supernova Survey: motivation, design, implementation, and first data release

    NASA Astrophysics Data System (ADS)

    Foley, Ryan J.; Scolnic, Daniel; Rest, Armin; Jha, S. W.; Pan, Y.-C.; Riess, A. G.; Challis, P.; Chambers, K. C.; Coulter, D. A.; Dettman, K. G.; Foley, M. M.; Fox, O. D.; Huber, M. E.; Jones, D. O.; Kilpatrick, C. D.; Kirshner, R. P.; Schultz, A. S. B.; Siebert, M. R.; Flewelling, H. A.; Gibson, B.; Magnier, E. A.; Miller, J. A.; Primak, N.; Smartt, S. J.; Smith, K. W.; Wainscoat, R. J.; Waters, C.; Willman, M.

    2018-03-01

    The Foundation Supernova Survey aims to provide a large, high-fidelity, homogeneous, and precisely calibrated low-redshift Type Ia supernova (SN Ia) sample for cosmology. The calibration of the current low-redshift SN sample is the largest component of systematic uncertainties for SN cosmology, and new data are necessary to make progress. We present the motivation, survey design, observation strategy, implementation, and first results for the Foundation Supernova Survey. We are using the Pan-STARRS telescope to obtain photometry for up to 800 SNe Ia at z ≲ 0.1. This strategy has several unique advantages: (1) the Pan-STARRS system is a superbly calibrated telescopic system, (2) Pan-STARRS has observed 3/4 of the sky in grizyP1 making future template observations unnecessary, (3) we have a well-tested data-reduction pipeline, and (4) we have observed ˜3000 high-redshift SNe Ia on this system. Here, we present our initial sample of 225 SN Ia grizP1 light curves, of which 180 pass all criteria for inclusion in a cosmological sample. The Foundation Supernova Survey already contains more cosmologically useful SNe Ia than all other published low-redshift SN Ia samples combined. We expect that the systematic uncertainties for the Foundation Supernova Sample will be two to three times smaller than other low-redshift samples. We find that our cosmologically useful sample has an intrinsic scatter of 0.111 mag, smaller than other low-redshift samples. We perform detailed simulations showing that simply replacing the current low-redshift SN Ia sample with an equally sized Foundation sample will improve the precision on the dark energy equation-of-state parameter by 35 per cent, and the dark energy figure of merit by 72 per cent.

  20. Development of signal processing system of avalanche photo diode for space observations by Astro-H

    NASA Astrophysics Data System (ADS)

    Ohno, M.; Goto, K.; Hanabata, Y.; Takahashi, H.; Fukazawa, Y.; Yoshino, M.; Saito, T.; Nakamori, T.; Kataoka, J.; Sasano, M.; Torii, S.; Uchiyama, H.; Nakazawa, K.; Watanabe, S.; Kokubun, M.; Ohta, M.; Sato, T.; Takahashi, T.; Tajima, H.

    2013-01-01

    Astro-H is the sixth Japanese X-ray space observatory which will be launched in 2014. Two of onboard instruments of Astro-H, Hard X-ray Imager and Soft Gamma-ray Detector are surrounded by many number of large Bismuth Germanate (Bi4Ge3O12; BGO) scintillators. Optimum readout system of scintillation lights from these BGOs are essential to reduce the background signals and achieve high performance for main detectors because most of gamma-rays from out of field-of-view of main detectors or radio-isotopes produced inside them due to activation can be eliminated by anti-coincidence technique using BGO signals. We apply Avalanche Photo Diode (APD) for light sensor of these BGO detectors since their compactness and high quantum efficiency make it easy to design such large number of BGO detector system. For signal processing from APDs, digital filter and other trigger logics on the Field-Programmable Gate Array (FPGA) is used instead of discrete analog circuits due to limitation of circuit implementation area on spacecraft. For efficient observations, we have to achieve as low threshold of anti-coincidence signal as possible by utilizing the digital filtering. In addition, such anti-coincident signals should be sent to the main detector within 5 μs to make it in time to veto the A-D conversion. Considering this requirement and constraint from logic size of FPGA, we adopt two types of filter, 8 delay taps filter with only 2 bit precision coefficient and 16 delay taps filter with 8 bit precision coefficient. The data after former simple filter provides anti-coincidence signal quickly in orbit, and the latter filter is used for detail analysis after the data is down-linked.

Top