42 CFR 84.103 - Man tests; performance requirements.
Code of Federal Regulations, 2013 CFR
2013-10-01
... 42 Public Health 1 2013-10-01 2013-10-01 false Man tests; performance requirements. 84.103 Section...-Contained Breathing Apparatus § 84.103 Man tests; performance requirements. (a) The apparatus shall satisfy... is 24 ±6 °C. (75 ±10 °F.), the maximum temperature of inspired air recorded during man tests shall...
42 CFR 84.103 - Man tests; performance requirements.
Code of Federal Regulations, 2014 CFR
2014-10-01
... 42 Public Health 1 2014-10-01 2014-10-01 false Man tests; performance requirements. 84.103 Section...-Contained Breathing Apparatus § 84.103 Man tests; performance requirements. (a) The apparatus shall satisfy... is 24 ±6 °C. (75 ±10 °F.), the maximum temperature of inspired air recorded during man tests shall...
42 CFR 84.103 - Man tests; performance requirements.
Code of Federal Regulations, 2012 CFR
2012-10-01
... 42 Public Health 1 2012-10-01 2012-10-01 false Man tests; performance requirements. 84.103 Section...-Contained Breathing Apparatus § 84.103 Man tests; performance requirements. (a) The apparatus shall satisfy... is 24 ±6 °C. (75 ±10 °F.), the maximum temperature of inspired air recorded during man tests shall...
42 CFR 84.103 - Man tests; performance requirements.
Code of Federal Regulations, 2010 CFR
2010-10-01
... 42 Public Health 1 2010-10-01 2010-10-01 false Man tests; performance requirements. 84.103 Section 84.103 Public Health PUBLIC HEALTH SERVICE, DEPARTMENT OF HEALTH AND HUMAN SERVICES OCCUPATIONAL SAFETY AND HEALTH RESEARCH AND RELATED ACTIVITIES APPROVAL OF RESPIRATORY PROTECTIVE DEVICES Self-Contained Breathing Apparatus § 84.103 Man tests;...
Code of Federal Regulations, 2013 CFR
2013-10-01
... 42 Public Health 1 2013-10-01 2013-10-01 false Man tests for gases and vapors; supplied-air respirators; general performance requirements. 84.159 Section 84.159 Public Health PUBLIC HEALTH SERVICE... APPROVAL OF RESPIRATORY PROTECTIVE DEVICES Supplied-Air Respirators § 84.159 Man tests for gases and vapors...
Code of Federal Regulations, 2014 CFR
2014-10-01
... 42 Public Health 1 2014-10-01 2014-10-01 false Man tests for gases and vapors; supplied-air respirators; general performance requirements. 84.159 Section 84.159 Public Health PUBLIC HEALTH SERVICE... APPROVAL OF RESPIRATORY PROTECTIVE DEVICES Supplied-Air Respirators § 84.159 Man tests for gases and vapors...
Code of Federal Regulations, 2012 CFR
2012-10-01
... 42 Public Health 1 2012-10-01 2012-10-01 false Man tests for gases and vapors; supplied-air respirators; general performance requirements. 84.159 Section 84.159 Public Health PUBLIC HEALTH SERVICE... APPROVAL OF RESPIRATORY PROTECTIVE DEVICES Supplied-Air Respirators § 84.159 Man tests for gases and vapors...
Kothe, Christian; Hissbach, Johanna; Hampe, Wolfgang
2014-01-01
Although some recent studies concluded that dexterity is not a reliable predictor of performance in preclinical laboratory courses in dentistry, they could not disprove earlier findings which confirmed the worth of manual dexterity tests in dental admission. We developed a wire bending test (HAM-Man) which was administered during dental freshmen's first week in 2008, 2009, and 2010. The purpose of our study was to evaluate if the HAM-Man is a useful selection criterion additional to the high school grade point average (GPA) in dental admission. Regression analysis revealed that GPA only accounted for a maximum of 9% of students' performance in preclinical laboratory courses, in six out of eight models the explained variance was below 2%. The HAM-Man incrementally explained up to 20.5% of preclinical practical performance over GPA. In line with findings from earlier studies the HAM-Man test of manual dexterity showed satisfactory incremental validity. While GPA has a focus on cognitive abilities, the HAM-Man reflects learning of unfamiliar psychomotor skills, spatial relationships, and dental techniques needed in preclinical laboratory courses. The wire bending test HAM-Man is a valuable additional selection instrument for applicants of dental schools.
Kothe, Christian; Hissbach, Johanna; Hampe, Wolfgang
2014-01-01
Although some recent studies concluded that dexterity is not a reliable predictor of performance in preclinical laboratory courses in dentistry, they could not disprove earlier findings which confirmed the worth of manual dexterity tests in dental admission. We developed a wire bending test (HAM-Man) which was administered during dental freshmen’s first week in 2008, 2009, and 2010. The purpose of our study was to evaluate if the HAM-Man is a useful selection criterion additional to the high school grade point average (GPA) in dental admission. Regression analysis revealed that GPA only accounted for a maximum of 9% of students’ performance in preclinical laboratory courses, in six out of eight models the explained variance was below 2%. The HAM-Man incrementally explained up to 20.5% of preclinical practical performance over GPA. In line with findings from earlier studies the HAM-Man test of manual dexterity showed satisfactory incremental validity. While GPA has a focus on cognitive abilities, the HAM-Man reflects learning of unfamiliar psychomotor skills, spatial relationships, and dental techniques needed in preclinical laboratory courses. The wire bending test HAM-Man is a valuable additional selection instrument for applicants of dental schools. PMID:24872857
NASA Technical Reports Server (NTRS)
1979-01-01
The tests and procedures for the manned remote work station (MRWS) open cherry picker (OCP) development test article (DTA) are described to validate systems requirements and performance specifications. A development test program is outlined to evaluate key design issues and man/machine interfaces when the MRWS OCP is used in a shuttle support role of satellite servicing and in orbit construction of large structures.
Code of Federal Regulations, 2010 CFR
2010-10-01
... 42 Public Health 1 2010-10-01 2010-10-01 false Man tests for gases and vapors; supplied-air respirators; general performance requirements. 84.159 Section 84.159 Public Health PUBLIC HEALTH SERVICE, DEPARTMENT OF HEALTH AND HUMAN SERVICES OCCUPATIONAL SAFETY AND HEALTH RESEARCH AND RELATED ACTIVITIES APPROVAL OF RESPIRATORY PROTECTIVE DEVICES...
Three-Man Solid Electrolyte Carbon Dioxide Electrolysis Breadboard
NASA Technical Reports Server (NTRS)
Isenberg, Arnold O.
1989-01-01
The development of the Three-Man (2.2 lb CO2/man-day) Solid Electrolyte CO2 Electrolysis Breadboard consisted of a Phase 1 and 2 effort. The Phase 1 effort constituted fabrication of three electrolysis cell types and performing parametric testing, off-design testing, and cell life testing. The Phase 2 consisted of the preliminary design, incorporation of palladium (Pd) tubes for hydrogen separation from the electrolyzer cathode feed gases, design support testing, final design, fabrication, and performance testing of the breadboard system. The results of performance tests demonstrated that CO2 electrolysis in an oxygen reclamation system for long duration space-based habitats is feasible. Closure of the oxygen system loop, therefore, can be achieved by CO2 electrolysis. In a two step process the metabolic CO2 and H2O vapor are electrolyzed into O2, H2, and CO. The CO can subsequently be disproportionated into carbon and CO2 in a carbon deposition reactor and the CO2 in turn be recycled and electrolyzed for total O2 recovery. The development effort demonstrated electrolyzer system can be designed and built to operate safely and reliably and the incorporation of Pd tubes for hydrogen diffusion can be integrated safely with predictable performance.
Motor Sensory Performance - Skylab Student Experiment ED-41
NASA Technical Reports Server (NTRS)
1973-01-01
This chart describes the Skylab student experiment Motor Sensory Performance, proposed by Kathy L. Jackson of Houston, Texas. Her proposal was a very simple but effective test to measure the potential degradation of man's motor-sensory skills while weightless. Without knowing whether or not man can retain a high level of competency in the performance of various tasks after long exposure to weightlessness, this capability could not be fully known. Skylab, with its long-duration missions, provided an ideal testing situation. The experiment Kathy Jackson proposed was similar in application to the tasks involved in docking one spacecraft to another using manual control. It required one of the greatest tests of the motor-sensory capabilities of man. In March 1972, NASA and the National Science Teachers Association selected 25 experiment proposals for flight on Skylab. Science advisors from the Marshall Space Flight Center aided and assisted the students in developing the proposals for flight on Skylab.
Technology demonstrator program for Space Station Environmental Control Life Support System
NASA Technical Reports Server (NTRS)
Adams, Alan M.; Platt, Gordon K.; Claunch, William C.; Humphries, William R.
1987-01-01
The main objectives and requirements of the NASA/Marshall Space Flight Center Technology Demonstration Program are discussed. The program consists of a comparative test and a 90-day manned system test to evaluate an Environmental Control and Life Support System (ECLSS). In the comparative test phase, 14 types of subsystems which perform oxygen and water reclamation functions are to be examined in terms of performance maintenance/service requirements, reliability, and safety. The manned chamber testing phase involves a four person crew using a partial ECLSS for 90 days. The schedule for the program and the program hardware requirements are described.
Strategies for Ground Based Testing of Manned Lunar Surface Systems
NASA Technical Reports Server (NTRS)
Beyer, Jeff; Peacock, Mike; Gill, Tracy
2009-01-01
Integrated testing (such as Multi-Element Integrated Test (MEIT)) is critical to reducing risks and minimizing problems encountered during assembly, activation, and on-orbit operation of large, complex manned spacecraft. Provides the best implementation of "Test Like You Fly:. Planning for integrated testing needs to begin at the earliest stages of Program definition. Program leadership needs to fully understand and buy in to what integrated testing is and why it needs to be performed. As Program evolves and design and schedules mature, continually look for suitable opportunities to perform testing where enough components are together in one place at one time. The benefits to be gained are well worth the costs.
2009 Navy ManTech Project Book
2009-01-01
pieces which are welded together, filled with syntactic foam , and welded to the sail and hull structure. The ManTech project was successful in...cladding has demonstrated the required performance characteristics . The testing demonstrated manufacturability of optical fibers with enhanced hard...using Liquid Injection Molding Simulation (LIMS) and Polyworx software tools for infusion set-up optimization. Test articles fabricated are
42 CFR 84.103 - Man tests; performance requirements.
Code of Federal Regulations, 2011 CFR
2011-10-01
... inspired air shall not exceed— °F. °C. 1/4 hour or less 0-100 135 57 1/4 hour to 3/4 hour 0-50 50-100 125 1 110 52 1 43 1 to 2 hours 0-50 50-100 115 1105 46 141 3 hours 0-50 50-100 110 1100 43 1 38 4 hours 0-50... 42 Public Health 1 2011-10-01 2011-10-01 false Man tests; performance requirements. 84.103 Section...
Huh, Hee Jae; Koh, Won-Jung; Song, Dong Joon
2014-01-01
We evaluated the performance of the Cobas TaqMan MTB test (Roche Diagnostics, Basel, Switzerland), stratified by acid-fast bacilli (AFB) smear grades. The sensitivity of this test in smear-positive specimens was >95% in all grades, while that in trace and negative specimens was 85.3% and 34.4%, respectively. PMID:25428157
Space station prototype Sabatier reactor design verification testing
NASA Technical Reports Server (NTRS)
Cusick, R. J.
1974-01-01
A six-man, flight prototype carbon dioxide reduction subsystem for the SSP ETC/LSS (Space Station Prototype Environmental/Thermal Control and Life Support System) was developed and fabricated for the NASA-Johnson Space Center between February 1971 and October 1973. Component design verification testing was conducted on the Sabatier reactor covering design and off-design conditions as part of this development program. The reactor was designed to convert a minimum of 98 per cent hydrogen to water and methane for both six-man and two-man reactant flow conditions. Important design features of the reactor and test conditions are described. Reactor test results are presented that show design goals were achieved and off-design performance was stable.
1973-01-01
This chart describes the Skylab student experiment Motor Sensory Performance, proposed by Kathy L. Jackson of Houston, Texas. Her proposal was a very simple but effective test to measure the potential degradation of man's motor-sensory skills while weightless. Without knowing whether or not man can retain a high level of competency in the performance of various tasks after long exposure to weightlessness, this capability could not be fully known. Skylab, with its long-duration missions, provided an ideal testing situation. The experiment Kathy Jackson proposed was similar in application to the tasks involved in docking one spacecraft to another using manual control. It required one of the greatest tests of the motor-sensory capabilities of man. In March 1972, NASA and the National Science Teachers Association selected 25 experiment proposals for flight on Skylab. Science advisors from the Marshall Space Flight Center aided and assisted the students in developing the proposals for flight on Skylab.
Vallefuoco, L; Sorrentino, R; Spalletti Cernia, D; Colucci, G; Portella, G
2012-12-01
The cobas p 630, a fully automated pre-analytical instrument for primary tube handling recently introduced to complete the Cobas(®) TaqMan systems portfolio, was evaluated in conjunction with: the COBAS(®) AmpliPrep/COBAS(®) TaqMan HBV Test, v2.0, COBAS(®) AmpliPrep/COBAS(®) TaqMan HCV Test, v1.0 and COBAS(®) AmpliPrep/COBAS(®) TaqMan HIV Test, v2.0. The instrument performance in transferring samples from primary to secondary tubes, its impact in improving COBAS(®) AmpliPrep/COBAS(®) TaqMan workflow and hands-on reduction and the risk of possible cross-contamination were assessed. Samples from 42 HBsAg positive, 42 HCV and 42 HIV antibody (Ab) positive patients as well as 21 healthy blood donors were processed with or without automated primary tubes. HIV, HCV and HBsAg positive samples showed a correlation index of 0.999, 0.987 and of 0.994, respectively. To assess for cross-contamination, high titer HBV DNA positive samples, HCV RNA and HIV RNA positive samples were distributed in the cobas p 630 in alternate tube positions, adjacent to negative control samples within the same rack. None of the healthy donor samples showed any reactivity. Based on these results, the cobas p 630 can improve workflow and sample tracing in laboratories performing molecular tests, and reduce turnaround time, errors, and risks. Copyright © 2012 Elsevier B.V. All rights reserved.
NASA Technical Reports Server (NTRS)
Huddleston, J. D.; Aylward, J. R.
1973-01-01
The investigations and testing associated with the CO2 removal efficiency and voltage degradation of a hydrogen depolarized carbon oxide concentrator are reported. Also discussed is the vibration testing of a water vapor electrolysis cell pair. Performance testing of various HDC cell pairs with Cs2CO3 electrolyte provided sufficient parametric and endurance data to size a six man space station prototype CO2 removal system as having 36 HDC cell pairs, and to verify a life capability exceeding six moths. Testing also demonstrated that tetramethylammonium carbonate is an acceptable HDC electrolyte for operating over the relative humidity range of 30 to 90 percent and over a temperature range of 50 to 80 F.
Huh, Hee Jae; Koh, Won-Jung; Song, Dong Joon; Ki, Chang-Seok; Lee, Nam Yong
2015-02-01
We evaluated the performance of the Cobas TaqMan MTB test (Roche Diagnostics, Basel, Switzerland), stratified by acid-fast bacilli (AFB) smear grades. The sensitivity of this test in smear-positive specimens was >95% in all grades, while that in trace and negative specimens was 85.3% and 34.4%, respectively. Copyright © 2015, American Society for Microbiology. All Rights Reserved.
One-man, self-contained CO2 concentrating system
NASA Technical Reports Server (NTRS)
Wynveen, R. A.; Schubert, F. H.; Powell, J. D.
1972-01-01
A program to design, fabricate, and test a 1-man, self-contained, electrochemical CO2 concentrating system is described. The system was designed with electronic controls and instrumentation to regulate performance, to analyze and display performance trends, and to detect and isolate faults. Ground support accessories were included to provide power, fluids, and a Parametric Data Display allowing real time indication of operating status in engineering units.
NASA Astrophysics Data System (ADS)
Borriello, G.; Bonori, V.; Cresti, M.; Dente, E.; Ideo, L.; Mazzi, G.; Usai, A.; Tafuto, A.; Togna, F.
2014-10-01
In this paper authors provide a description of the currently deployed Man Portable Air Defense System (ManPADS) heat-seeking missiles. Principles of IR seeking and Aircraft signatures are shortly described. Basic information are listed on currently designed Infra-Red Counter Measure Systems, intended to protect Aircrafts against ManPADS. Authors provide an overview on ELT-572(v)2 DIRCM Program, funded by Italian Air Force, currently in low rate production phase. Description of the Design and Development phase, completed in Elettronica SpA in 2013, is reported. Development Test and Evaluation (DTE) Activities on ELT-572(v)2 DIRCM, jointly performed by Elettronica Spa and Italian Air Force Flight Test Centre, are shortly described. A summary of tests and some results are also discussed. Platform Installation Programs, using the low rate production units from ELT-572(v)2 DIRCM Program, are finally listed.
42 CFR 84.99 - Man tests; testing conditions; general requirements.
Code of Federal Regulations, 2012 CFR
2012-10-01
... 42 Public Health 1 2012-10-01 2012-10-01 false Man tests; testing conditions; general requirements...-Contained Breathing Apparatus § 84.99 Man tests; testing conditions; general requirements. (a) The man tests...) All man tests will be conducted by the Institute. (d) The apparatus will be examined before each man...
42 CFR 84.99 - Man tests; testing conditions; general requirements.
Code of Federal Regulations, 2014 CFR
2014-10-01
... 42 Public Health 1 2014-10-01 2014-10-01 false Man tests; testing conditions; general requirements...-Contained Breathing Apparatus § 84.99 Man tests; testing conditions; general requirements. (a) The man tests...) All man tests will be conducted by the Institute. (d) The apparatus will be examined before each man...
42 CFR 84.99 - Man tests; testing conditions; general requirements.
Code of Federal Regulations, 2011 CFR
2011-10-01
... 42 Public Health 1 2011-10-01 2011-10-01 false Man tests; testing conditions; general requirements...-Contained Breathing Apparatus § 84.99 Man tests; testing conditions; general requirements. (a) The man tests...) All man tests will be conducted by the Institute. (d) The apparatus will be examined before each man...
42 CFR 84.99 - Man tests; testing conditions; general requirements.
Code of Federal Regulations, 2013 CFR
2013-10-01
... 42 Public Health 1 2013-10-01 2013-10-01 false Man tests; testing conditions; general requirements...-Contained Breathing Apparatus § 84.99 Man tests; testing conditions; general requirements. (a) The man tests...) All man tests will be conducted by the Institute. (d) The apparatus will be examined before each man...
ERIC Educational Resources Information Center
Levensky, Kay
As a part of the National Study of American Indian Education, this document reports on 1700 American Indian primary school children (representing 14 tribal groups and 12 states) who were administered the Goodenough Draw-A-Man Test (DAM) as a measure of mental alertness. A comparison is given of the Indian and white children's scores. It appears…
Improving the Predictive Validity of the Draw-A-Man Test as a Screening Device for School Readiness.
ERIC Educational Resources Information Center
Simner, Marvin L.
An item analysis of Harris' scoring system for the Goodenough-Harris Draw-A-Man Test was conducted by comparing sets of protocols obtained in the early fall of kindergarten from children whose overall in-class academic performance placed them either in an at-risk category (N=21) or at the top of their class (N=38) by the end of the school year.…
The multi-axis vibration environment and man.
Lovesey, E J
1970-12-01
Many investigations into the effects of vibration on man have been performed since Mallock's first study of London Underground vibrations in 1902. The vibration research has tended to be confined to the vertical (heave) axis, yet recent experiments have indicated that low frequency vibration along the lateral (sway) axis has a greater adverse effect upon comfort and performance. Measurements of the vibration environments in current forms of transport including motor vehicles, hovercraft and aircraft etc have shown that appreciable quantities of vibration along all three axes exist. Further vibration research should consider the effects of multi-axis vibrations upon man rather than limit tests to single axis vibration.
A Review of the Biomedical Effects of Marihuana on Man in the Military Environment
The review documents in detail the current state of knowledge of the effects of marihuana on man. The study examines the relationships between... marihuana use and performance of the man in a military environment and identifies opportunities for future research by the Army in this field. The scope of...review includes a description of behavioral tests used to measure marihuana effects, the influence of an individual’s expectations, and effects of
Use of COTS Batteries on ISS and Shuttle
NASA Technical Reports Server (NTRS)
Jeevarajan, Judith A.
2004-01-01
This presentation focuses on COTS Battery testing for energy content, toxicity, hazards, failures modes and controls for different battery chemistries. It also discusses the current program requirements, challenges with COTS Batteries in manned vehicle COTS methodology, JSC test details, and gives a list of incidents from consumer protection safety commissions. The Battery test process involved testing new batteries for engineering certification, qualification of batteries, flight acceptance, cell and battery, environment, performance and abuse. Their conclusions and recommendations were that: high risk is undertaken with the use of COTS batteries, hazard control verification is required to allow the use of these batteries on manned space flights, failures during use cannot be understood if different scenarios of failure are not tested on the ground, and that testing is performed on small sample numbers due to restrictions on cost and time. They recommend testing of large sample size to gain more confidence in the operation of the hazard controls.
NASA Technical Reports Server (NTRS)
Propp, C. E.; Mcgee, J. M.
1971-01-01
The Apollo 13 anomaly provided considerable impetus for a variety of types of cryogenic and ignition tests. The logic of the various test program designs, the test techniques, and their final impact upon the investigation findings are described. In addition, several test programs initiated to determine the thermal performance and general performance characteristics of the redesigned Apollo 14 cryogenic storage system are presented.
Pharmacogenetics of clopidogrel: comparison between a standard and a rapid genetic testing.
Saracini, Claudia; Vestrini, Anna; Galora, Silvia; Armillis, Alessandra; Abbate, Rosanna; Giusti, Betti
2012-06-01
CYP2C19 variant alleles are independent predictors of clopidogrel response variability and occurrence of major adverse cardiovascular events in high-risk vascular patients on clopidogrel therapy. Increasing evidence suggests a combination of platelet function testing with CYP2C19 genetic testing may be more effective in identifying high-risk individuals for alternative antiplatelet therapeutic strategies. A crucial point in evaluating the use of these polymorphisms in clinical practice, besides test accuracy, is the cost of the genetic test and rapid availability of the results. One hundred acute coronary syndrome patients were genotyped for CYP2C19*2,*3,*4,*5, and *17 polymorphisms with two platforms: Verigene(®) and the TaqMan(®) system. Genotyping results obtained by the classical TaqMan approach and the rapid Verigene approach showed a 100% concordance for all the five polymorphisms investigated. The Verigene system had shorter turnaround time with respect to TaqMan. The cost of reagents for TaqMan genotyping was lower than that for the Verigene system, but the effective manual staff involvement and the relative cost resulted in higher cost for TaqMan than for Verigene. The Verigene system demonstrated good performance in terms of turnaround time and cost for the evaluation of the clopidogrel poor metabolizer status, giving genetic information in suitable time (206 min) for a therapeutic strategy decision.
NASA Technical Reports Server (NTRS)
Kohl, Randall L.; Homick, Jerry L.; Cintron, Nitza; Calkins, Dick S.
1987-01-01
Astemizole was orally administered to 20 subjects in a randomized, double-blind design to assess the efficacy of this peripherally active antihistamine as an antimotion sickness drug possessing no central side-effects. Measures of vestibular ocular reflex (VOR) were made to evaluate the agent as a selective vestibular depressant. Following one week of orally administered astemizole (30 mg daily), a Staircase Profile Test, a VOR test, and a variety of tests of cognitive performance were administered. These tests revealed no statistically significant effects of astemizole. This leads to the conclusion that, although the drug probably reaches the peripheral vestibular apparatus in man by crossing the blood-vestibular barrier, a selective peripheral antihistamine (H1) action is inadequate to control motion sickness induced through cross-coupled accelerative semicircular canal stimulation in a rotating chair.
NASA Technical Reports Server (NTRS)
1970-01-01
A developmental test plan for the wheel and wheel drive assembly of the dual-mode (manned/automated) lunar surface roving vehicle is presented. The tests cover performance, as well as critical environmental characteristics. Insofar as practical, the environmental conditions imposed will be in the sequence expected during the hardware's life from storage through the lunar mission. Test procedures are described for static load deflection and endurance tests. Soft soil tests to determine mobility characteristics including drawbar-pull and thrust vs slip, and motion resistance for various wheel loads are also discussed. Test designs for both ambient and thermal vacuum conditions are described. Facility, transducer, and instrumentation requirements are outlined.
Altitude Chamber Testing of the Passenger Oxygen System (POS)
2009-08-01
4 5.0 Schedule 4 6.0 Method for Unmanned Testing 4 7.0 Unmanned Testing Results 6 8.0 Methods for Manned...manned testing. 30 Mar 09: Subjects received orientation and training briefings. 31 Mar-03 Apr 09: POS manned testing conducted. 6.0 Method ...8.0 Methods for Manned Testing: The system was tested in five manned modes. The details of each mode are described in Appendix B (ICD for
View of White Room atop Pad A during Apollo 9 Countdown Demonstration Test
1969-02-23
S69-25884 (23 Feb. 1969) --- Interior view of the white room atop Pad A, Launch Complex 39, Kennedy Space Center, during Apollo 9 Countdown Demonstration Test activity. Standing next to spacecraft hatch is astronaut James A. McDivitt, commander. Also, taking part in the training exercise were astronauts David R. Scott, command module pilot; and Russell L. Schweickart, lunar module pilot. The Apollo 9 mission will evaluate spacecraft lunar module systems performance during manned Earth-orbital flight. Apollo 9 will be the second manned Saturn V mission.
Do Performers' Experience and Sex Affect Their Performance?
Emmanuel, Jacobs; Nathalie, Roussel; Van Caekenberghe, Ine; Cassiers, Edith; Van den Dries, Luc; Rutgeerts, Jonas; Gielen, Jan; Hallemans, Ann
2017-04-01
This cross-sectional study aimed at developing a biomechanical method to objectify voluntary and unpredictable movements, using an automated three-dimensional motion capture system and surface electromyography. Fourteen experienced theater performers were tested while executing the old man exercise, wherein they have to walk like an old man, building up a sustained high intensive muscular activity and tremor. Less experienced performed showed a different kinematics of movement, a slower speed of progression and more variable EMG signals at higher intensity. Female performers also differed from males in movement kinematics and muscular activity. The number of the trial only influenced the speed of progression. The performers showed results which could be well placed within the stages of learning and the degrees of freedom problem.
Orbit Transfer Vehicle (OTV) engine, phase A study. Volume 2: Study
NASA Technical Reports Server (NTRS)
Mellish, J. A.
1979-01-01
The hydrogen oxygen engine used in the orbiter transfer vehicle is described. The engine design is analyzed and minimum engine performance and man rating requirements are discussed. Reliability and safety analysis test results are presented and payload, risk and cost, and engine installation parameters are defined. Engine tests were performed including performance analysis, structural analysis, thermal analysis, turbomachinery analysis, controls analysis, and cycle analysis.
The sperm count test is performed if a man's fertility is in question. It is helpful in determining if there is a problem in sperm production or quality of the sperm as a cause of infertility. The test may also be used after ...
Pilot-in-the-Loop CFD Method Development
2017-04-20
the methods on the NAVAIR Manned Flight Simulator. Activities this period During this report period, we implemented the CRAFT CFD code on the...Penn State VLRCROE Flight simulator and performed the first Pilot-in-the-Loop PILCFD tests at Penn State using the COCOA5 clusters. The initial tests...integration of the flight simulator and Penn State computing infrastructure. Initial tests showed slower performance than real-time (3x slower than real
The space shuttle launch vehicle aerodynamic verification challenges
NASA Technical Reports Server (NTRS)
Wallace, R. O.; Austin, L. D.; Hondros, J. G.; Surber, T. E.; Gaines, L. M.; Hamilton, J. T.
1985-01-01
The Space Shuttle aerodynamics and performance communities were challenged to verify the Space Shuttle vehicle (SSV) aerodynamics and system performance by flight measurements. Historically, launch vehicle flight test programs which faced these same challenges were unmanned instrumented flights of simple aerodynamically shaped vehicles. However, the manned SSV flight test program made these challenges more complex because of the unique aerodynamic configuration powered by the first man-rated solid rocket boosters (SRB). The analyses of flight data did not verify the aerodynamics or performance preflight predictions of the first flight of the Space Transportation System (STS-1). However, these analyses have defined the SSV aerodynamics and verified system performance. The aerodynamics community also was challenged to understand the discrepancy between the wind tunnel and flight defined aerodynamics. The preflight analysis challenges, the aerodynamic extraction challenges, and the postflight analyses challenges which led to the SSV system performance verification and which will lead to the verification of the operational ascent aerodynamics data base are presented.
DOT National Transportation Integrated Search
1969-04-01
Male subjects were tested after extensive training as two five-man 'crews' in an experiment designed to examine the effects of signal rate on the performance of a task involving the monitoring of a dynamic process. Performance was measured using thre...
42 CFR 84.102 - Man test 6; requirements.
Code of Federal Regulations, 2011 CFR
2011-10-01
... 42 Public Health 1 2011-10-01 2011-10-01 false Man test 6; requirements. 84.102 Section 84.102 Public Health PUBLIC HEALTH SERVICE, DEPARTMENT OF HEALTH AND HUMAN SERVICES OCCUPATIONAL SAFETY AND... Breathing Apparatus § 84.102 Man test 6; requirements. (a) Man test 6 will be conducted with respect to...
42 CFR 84.102 - Man test 6; requirements.
Code of Federal Regulations, 2014 CFR
2014-10-01
... 42 Public Health 1 2014-10-01 2014-10-01 false Man test 6; requirements. 84.102 Section 84.102 Public Health PUBLIC HEALTH SERVICE, DEPARTMENT OF HEALTH AND HUMAN SERVICES OCCUPATIONAL SAFETY AND... Breathing Apparatus § 84.102 Man test 6; requirements. (a) Man test 6 will be conducted with respect to...
42 CFR 84.102 - Man test 6; requirements.
Code of Federal Regulations, 2012 CFR
2012-10-01
... 42 Public Health 1 2012-10-01 2012-10-01 false Man test 6; requirements. 84.102 Section 84.102 Public Health PUBLIC HEALTH SERVICE, DEPARTMENT OF HEALTH AND HUMAN SERVICES OCCUPATIONAL SAFETY AND... Breathing Apparatus § 84.102 Man test 6; requirements. (a) Man test 6 will be conducted with respect to...
42 CFR 84.102 - Man test 6; requirements.
Code of Federal Regulations, 2013 CFR
2013-10-01
... 42 Public Health 1 2013-10-01 2013-10-01 false Man test 6; requirements. 84.102 Section 84.102 Public Health PUBLIC HEALTH SERVICE, DEPARTMENT OF HEALTH AND HUMAN SERVICES OCCUPATIONAL SAFETY AND... Breathing Apparatus § 84.102 Man test 6; requirements. (a) Man test 6 will be conducted with respect to...
1979-05-01
This montage depicts the flight crew patches for the manned Apollo 7 thru Apollo 17 missions. The Apollo 7 through 10 missions were basically manned test flights that paved the way for lunar landing missions. Primary objectives met included the demonstration of the Command Service Module (CSM) crew performance; crew/space vehicle/mission support facilities performance and testing during a manned CSM mission; CSM rendezvous capability; translunar injection demonstration; the first manned Apollo docking, the first Apollo Extra Vehicular Activity (EVA), performance of the first manned flight of the lunar module (LM); the CSM-LM docking in translunar trajectory, LM undocking in lunar orbit, LM staging in lunar orbit, and manned LM-CSM docking in lunar orbit. Apollo 11 through 17 were lunar landing missions with the exception of Apollo 13 which was forced to circle the moon without landing due to an onboard explosion. The craft was,however, able to return to Earth safely. Apollo 11 was the first manned lunar landing mission and performed the first lunar surface EVA. Landing site was the Sea of Tranquility. A message for mankind was delivered, the U.S. flag was planted, experiments were set up and 47 pounds of lunar surface material was collected for analysis back on Earth. Apollo 12, the 2nd manned lunar landing mission landed in the Ocean of Storms and retrieved parts of the unmanned Surveyor 3, which had landed on the Moon in April 1967. The Apollo Lunar Surface Experiments Package (ALSEP) was deployed, and 75 pounds of lunar material was gathered. Apollo 14, the 3rd lunar landing mission landed in Fra Mauro. ALSEP and other instruments were deployed, and 94 pounds of lunar materials were gathered, using a hand cart for first time to transport rocks. Apollo 15, the 4th lunar landing mission landed in the Hadley-Apennine region. With the first use of the Lunar Roving Vehicle (LRV), the crew was bale to gather 169 pounds of lunar material. Apollo 16, the 5th lunar landing mission, landed in the Descartes Highlands for the first study of highlands area. Selected surface experiments were deployed, the ultraviolet camera/spectrograph was used for first time on the Moon, and the LRV was used for second time for a collection of 213 pounds of lunar material. The Apollo program came to a close with Apollo 17, the 6th and final manned lunar landing mission that landed in the Taurus-Littrow highlands and valley area. This mission hosted the first scientist-astronaut, Schmitt, to land on the Moon. The 6th automated research station was set up, and 243 ponds of lunar material was gathered using the LRV.
Montage of Apollo Crew Patches
NASA Technical Reports Server (NTRS)
1979-01-01
This montage depicts the flight crew patches for the manned Apollo 7 thru Apollo 17 missions. The Apollo 7 through 10 missions were basically manned test flights that paved the way for lunar landing missions. Primary objectives met included the demonstration of the Command Service Module (CSM) crew performance; crew/space vehicle/mission support facilities performance and testing during a manned CSM mission; CSM rendezvous capability; translunar injection demonstration; the first manned Apollo docking, the first Apollo Extra Vehicular Activity (EVA), performance of the first manned flight of the lunar module (LM); the CSM-LM docking in translunar trajectory, LM undocking in lunar orbit, LM staging in lunar orbit, and manned LM-CSM docking in lunar orbit. Apollo 11 through 17 were lunar landing missions with the exception of Apollo 13 which was forced to circle the moon without landing due to an onboard explosion. The craft was,however, able to return to Earth safely. Apollo 11 was the first manned lunar landing mission and performed the first lunar surface EVA. Landing site was the Sea of Tranquility. A message for mankind was delivered, the U.S. flag was planted, experiments were set up and 47 pounds of lunar surface material was collected for analysis back on Earth. Apollo 12, the 2nd manned lunar landing mission landed in the Ocean of Storms and retrieved parts of the unmanned Surveyor 3, which had landed on the Moon in April 1967. The Apollo Lunar Surface Experiments Package (ALSEP) was deployed, and 75 pounds of lunar material was gathered. Apollo 14, the 3rd lunar landing mission landed in Fra Mauro. ALSEP and other instruments were deployed, and 94 pounds of lunar materials were gathered, using a hand cart for first time to transport rocks. Apollo 15, the 4th lunar landing mission landed in the Hadley-Apennine region. With the first use of the Lunar Roving Vehicle (LRV), the crew was bale to gather 169 pounds of lunar material. Apollo 16, the 5th lunar landing mission, landed in the Descartes Highlands for the first study of highlands area. Selected surface experiments were deployed, the ultraviolet camera/spectrograph was used for first time on the Moon, and the LRV was used for second time for a collection of 213 pounds of lunar material. The Apollo program came to a close with Apollo 17, the 6th and final manned lunar landing mission that landed in the Taurus-Littrow highlands and valley area. This mission hosted the first scientist-astronaut, Schmitt, to land on the Moon. The 6th automated research station was set up, and 243 ponds of lunar material was gathered using the LRV.
1971-08-14
N-243 Flight and Guidance Centrifuge: Is used for spacecraft mission simulations and is adaptable to two configurations. Configuration 1: The cab will accommodate a three-man crew for space mission research. The accelerations and rates are intended to be smoothly applicable at very low value so the navigation and guidance procedures using a high-accuracy, out-the window display may be simulated. Configuration 2: The simulator can use a one-man cab for human tolerance studies and performance testing. Atmosphere and tempertaure can be varied as stress inducements. This simlator is operated closed-loop with digital or analog computation. It is currently man-rated for 3.5g maximum.
1971-08-14
N-243 Flight and Guidance Centrifuge: Is used for spacecraft mission simulations and is adaptable to two configurations. Configuration 1: The cab will accommodate a three-man crew for space mission research. The accelerations and rates are intended to be smoothly applicable at very low value so the navigation and guidance procedures using a high-accuracy, out-the window display may be simulated. Configuration 2: The simulator can use a one-man cab for human tolerance studies and performance testing. Atmosphere and tempertaure can be varied as stress inducements. This simlator is operated closed-loop with digital or analog computation. It is currently man-rated for 3.5g maximum.
1971-08-14
N-243 Flight and Guidance Centrifuge: Is used for spacecraft mission simulations and is adaptable to two configurations. Configuration 1: The cab will accommodate a three-man crew for space mission research. The accelerations and rates are intended to be smoothly applicable at very low value so the navigation and guidance procedures using a high-accuracy, out-the window display may be simulated. Configuration 2: The simulator can use a one-man cab for human tolerance studies and performance testing. Atmosphere and tempertaure can be varied as stress inducements. This simlator is operated closed-loop with digital or analog computation. It is currently man-rated for 3.5g maximum.
42 CFR 84.100 - Man tests 1, 2, 3, and 4; requirements.
Code of Federal Regulations, 2014 CFR
2014-10-01
... 42 Public Health 1 2014-10-01 2014-10-01 false Man tests 1, 2, 3, and 4; requirements. 84.100 Section 84.100 Public Health PUBLIC HEALTH SERVICE, DEPARTMENT OF HEALTH AND HUMAN SERVICES OCCUPATIONAL...-Contained Breathing Apparatus § 84.100 Man tests 1, 2, 3, and 4; requirements. Man tests 1, 2, 3, and 4, set...
42 CFR 84.100 - Man tests 1, 2, 3, and 4; requirements.
Code of Federal Regulations, 2013 CFR
2013-10-01
... 42 Public Health 1 2013-10-01 2013-10-01 false Man tests 1, 2, 3, and 4; requirements. 84.100 Section 84.100 Public Health PUBLIC HEALTH SERVICE, DEPARTMENT OF HEALTH AND HUMAN SERVICES OCCUPATIONAL...-Contained Breathing Apparatus § 84.100 Man tests 1, 2, 3, and 4; requirements. Man tests 1, 2, 3, and 4, set...
42 CFR 84.100 - Man tests 1, 2, 3, and 4; requirements.
Code of Federal Regulations, 2012 CFR
2012-10-01
... 42 Public Health 1 2012-10-01 2012-10-01 false Man tests 1, 2, 3, and 4; requirements. 84.100 Section 84.100 Public Health PUBLIC HEALTH SERVICE, DEPARTMENT OF HEALTH AND HUMAN SERVICES OCCUPATIONAL...-Contained Breathing Apparatus § 84.100 Man tests 1, 2, 3, and 4; requirements. Man tests 1, 2, 3, and 4, set...
Holguín, Africa; López, Marisa; Molinero, Mar; Soriano, Vincent
2008-09-01
Monitoring antiretroviral therapy requires that human immunodeficiency virus type 1 (HIV-1) viremia assays are applicable to all distinct variants. This study evaluates the performance of three commercial viral load assays-Versant HIV-1 RNA bDNA v3.0, Cobas AmpliPrep/Cobas TaqMan HIV-1, and NucliSens HIV-1 EasyQ v1.2-in testing 83 plasma specimens from patients carrying HIV-1 non-B subtypes and recombinants previously defined by phylogenetic analysis of the pol gene. All 28 specimens from patients under treatment presented viremia values below the detection limit with the three methods. In the remaining 55 specimens from naive individuals viremia could not be detected in 32.7, 20, and 14.6% using the NucliSens, Versant, or TaqMan tests, respectively, suggesting potential viral load underestimation of some samples by all techniques. Only 32 (58.2%) samples from naive subjects were quantified by the three methods; the NucliSens test provided the highest HIV RNA values (mean, 4.87 log copies/ml), and the Versant test provided the lowest (mean, 4.16 log copies/ml). Viremia differences of greater than 1 log were seen in 8 (14.5%) of 55 specimens, occurring in 10.9, 7.3, and 5.4%, respectively, of the specimens in comparisons of Versant versus NucliSens, Versant versus TaqMan, and TaqMan versus NucliSens. Differences greater than 0.5 log, considered significant for clinicians, occurred in 45.5, 27.3, and 29% when the same assays were compared. Some HIV-1 strains, such as subtype G and CRF02_AG, showed more discrepancies in distinct quantification methods than others. In summary, an adequate design of primers and probes is needed for optimal quantitation of plasma HIV-RNA in non-B subtypes. Our data emphasize the need to use the same method for monitoring patients on therapy and also the convenience of HIV-1 subtyping.
42 CFR 84.100 - Man tests 1, 2, 3, and 4; requirements.
Code of Federal Regulations, 2011 CFR
2011-10-01
... 42 Public Health 1 2011-10-01 2011-10-01 false Man tests 1, 2, 3, and 4; requirements. 84.100...-Contained Breathing Apparatus § 84.100 Man tests 1, 2, 3, and 4; requirements. Man tests 1, 2, 3, and 4, set forth in Tables 1, 2, 3, and 4 of this subpart, respectively, prescribe the duration and sequence of...
Safety validation test equipment operation
NASA Astrophysics Data System (ADS)
Kurosaki, Tadaaki; Watanabe, Takashi
1992-08-01
An overview of the activities conducted on safety validation test equipment operation for materials used for NASA manned missions is presented. Safety validation tests, such as flammability, odor, offgassing, and so forth were conducted in accordance with NASA-NHB-8060.1C using test subjects common with those used by NASA, and the equipment used were qualified for their functions and performances in accordance with NASDA-CR-99124 'Safety Validation Test Qualification Procedures.' Test procedure systems were established by preparing 'Common Procedures for Safety Validation Test' as well as test procedures for flammability, offgassing, and odor tests. The test operation organization chaired by the General Manager of the Parts and Material Laboratory of NASDA (National Space Development Agency of Japan) was established, and the test leaders and operators in the organization were qualified in accordance with the specified procedures. One-hundred-one tests had been conducted so far by the Parts and Material Laboratory according to the request submitted by the manufacturers through the Space Station Group and the Safety and Product Assurance for Manned Systems Office.
DOT National Transportation Integrated Search
1977-01-01
The report describes the installation and load test of the world's first press-lam timber bridge superstructure. A five-man crew replaced the substandard steel stringer-timber deck superstructure on Rte. 610 over Little Stoney Creek in Shenandoah Cou...
Performance of the SNPforID 52 SNP-plex assay in paternity testing.
Børsting, Claus; Sanchez, Juan J; Hansen, Hanna E; Hansen, Anders J; Bruun, Hanne Q; Morling, Niels
2008-09-01
The performance of a multiplex assay with 52 autosomal single nucleotide polymorphisms (SNPs) developed for human identification was tested on 124 mother-child-father trios. The typical paternity indices (PIs) were 10(5)-10(6) for the trios and 10(3)-10(4) for the child-father duos. Using the SNP profiles from the randomly selected trios and 700 previously typed individuals, a total of 83,096 comparisons between mother, child and an unrelated man were performed. On average, 9-10 mismatches per comparison were detected. Four mismatches were genetic inconsistencies and 5-6 mismatches were opposite homozygosities. In only two of the 83,096 comparisons did an unrelated man match perfectly to a mother-child duo, and in both cases the PI of the true father was much higher than the PI of the unrelated man. The trios were also typed for 15 short tandem repeats (STRs) and seven variable number of tandem repeats (VNTRs). The typical PIs based on 15 STRs or seven VNTRs were 5-50 times higher than the typical PIs based on 52 SNPs. Six mutations in tandem repeats were detected among the randomly selected trios. In contrast, there was not found any mutations in the SNP loci. The results showed that the 52 SNP-plex assay is a very useful alternative to currently used methods in relationship testing. The usefulness of SNP markers with low mutation rates in paternity and immigration casework is discussed.
42 CFR 84.161 - Man test for gases and vapors; Type B and Type BE respirators; test requirements.
Code of Federal Regulations, 2013 CFR
2013-10-01
... 42 Public Health 1 2013-10-01 2013-10-01 false Man test for gases and vapors; Type B and Type BE... RESPIRATORY PROTECTIVE DEVICES Supplied-Air Respirators § 84.161 Man test for gases and vapors; Type B and... 25 percent of the hose length will be located in isoamyl acetate-free air. (b) The man in the isoamyl...
42 CFR 84.161 - Man test for gases and vapors; Type B and Type BE respirators; test requirements.
Code of Federal Regulations, 2012 CFR
2012-10-01
... 42 Public Health 1 2012-10-01 2012-10-01 false Man test for gases and vapors; Type B and Type BE... RESPIRATORY PROTECTIVE DEVICES Supplied-Air Respirators § 84.161 Man test for gases and vapors; Type B and... 25 percent of the hose length will be located in isoamyl acetate-free air. (b) The man in the isoamyl...
42 CFR 84.161 - Man test for gases and vapors; Type B and Type BE respirators; test requirements.
Code of Federal Regulations, 2014 CFR
2014-10-01
... 42 Public Health 1 2014-10-01 2014-10-01 false Man test for gases and vapors; Type B and Type BE... RESPIRATORY PROTECTIVE DEVICES Supplied-Air Respirators § 84.161 Man test for gases and vapors; Type B and... 25 percent of the hose length will be located in isoamyl acetate-free air. (b) The man in the isoamyl...
42 CFR 84.160 - Man test for gases and vapors; Type A and Type AE respirators; test requirements.
Code of Federal Regulations, 2013 CFR
2013-10-01
... 42 Public Health 1 2013-10-01 2013-10-01 false Man test for gases and vapors; Type A and Type AE... RESPIRATORY PROTECTIVE DEVICES Supplied-Air Respirators § 84.160 Man test for gases and vapors; Type A and... not more than 25 percent of the hose length will be located in isoamyl acetate-free air. (b) The man...
42 CFR 84.160 - Man test for gases and vapors; Type A and Type AE respirators; test requirements.
Code of Federal Regulations, 2014 CFR
2014-10-01
... 42 Public Health 1 2014-10-01 2014-10-01 false Man test for gases and vapors; Type A and Type AE... RESPIRATORY PROTECTIVE DEVICES Supplied-Air Respirators § 84.160 Man test for gases and vapors; Type A and... not more than 25 percent of the hose length will be located in isoamyl acetate-free air. (b) The man...
42 CFR 84.160 - Man test for gases and vapors; Type A and Type AE respirators; test requirements.
Code of Federal Regulations, 2012 CFR
2012-10-01
... 42 Public Health 1 2012-10-01 2012-10-01 false Man test for gases and vapors; Type A and Type AE... RESPIRATORY PROTECTIVE DEVICES Supplied-Air Respirators § 84.160 Man test for gases and vapors; Type A and... not more than 25 percent of the hose length will be located in isoamyl acetate-free air. (b) The man...
Program operational summary: Operational 90 day manned test of a regenerative life support system
NASA Technical Reports Server (NTRS)
Jackson, J. K.; Wamsley, J. R.; Bonura, M. S.; Seeman, J. S.
1972-01-01
An operational 90-day manned test of a regenerative life support system was successfully completed. This test was performed with a crew of four carefully selected and trained men in a space station simulator (SSS) which had a two gas atmosphere maintained at a total pressure of 68.9, 10 psia, and composed of oxygen at a partial pressure of 3.05 psia with nitrogen as the diluent. The test was planned to provide data on regenerative life support subsystems and on integrated system operations in a closed ecology, similar to that of a space station. All crew equipment and expendables were stored onboard at the start of the mission to eliminate the need for pass-in operations. The significant accomplishments of the test, some of the pertinent test results, some of the problem areas, and conclusions are presented.
Distribution of man-machine controls in space teleoperation
NASA Technical Reports Server (NTRS)
Bejczy, A. K.
1982-01-01
The distribution of control between man and machine is dependent on the tasks, available technology, human performance characteristics and control goals. This dependency has very specific projections on systems designed for teleoperation in space. This paper gives a brief outline of the space-related issues and presents the results of advanced teleoperator research and development at the Jet Propulsion Laboratory (JPL). The research and development work includes smart sensors, flexible computer controls and intelligent man-machine interface devices in the area of visual displays and kinesthetic man-machine coupling in remote control of manipulators. Some of the development results have been tested at the Johnson Space Center (JSC) using the simulated full-scale Shuttle Remote Manipulator System (RMS). The research and development work for advanced space teleoperation is far from complete and poses many interdisciplinary challenges.
ERIC Educational Resources Information Center
Elrod, G. Franklin; Obringer, S. John
Many researchers have attempted to link children's drawings to intelligence. The Goodenough-Harris Draw-a-Man (DAM) and Draw-a-Woman (DAW) test has been accepted as an indicator of intelligence. This study, via examination of specific cases, explored the effect that instruction in drawing cartoons had on the DAM and DAW performance of 16…
Control system software, simulation, and robotic applications
NASA Technical Reports Server (NTRS)
Frisch, Harold P.
1991-01-01
All essential existing capabilities needed to create a man-machine interaction dynamics and performance (MMIDAP) capability are reviewed. The multibody system dynamics software program Order N DISCOS will be used for machine and musculo-skeletal dynamics modeling. The program JACK will be used for estimating and animating whole body human response to given loading situations and motion constraints. The basic elements of performance (BEP) task decomposition methodologies associated with the Human Performance Institute database will be used for performance assessment. Techniques for resolving the statically indeterminant muscular load sharing problem will be used for a detailed understanding of potential musculotendon or ligamentous fatigue, pain, discomfort, and trauma. The envisioned capacity is to be used for mechanical system design, human performance assessment, extrapolation of man/machine interaction test data, biomedical engineering, and soft prototyping within a concurrent engineering (CE) system.
The human role in space (THURIS) applications study. Final briefing
NASA Technical Reports Server (NTRS)
Maybee, George W.
1987-01-01
The THURIS (The Human Role in Space) application is an iterative process involving successive assessments of man/machine mixes in terms of performance, cost and technology to arrive at an optimum man/machine mode for the mission application. The process begins with user inputs which define the mission in terms of an event sequence and performance time requirements. The desired initial operational capability date is also an input requirement. THURIS terms and definitions (e.g., generic activities) are applied to the input data converting it into a form which can be analyzed using the THURIS cost model outputs. The cost model produces tabular and graphical outputs for determining the relative cost-effectiveness of a given man/machine mode and generic activity. A technology database is provided to enable assessment of support equipment availability for selected man/machine modes. If technology gaps exist for an application, the database contains information supportive of further investigation into the relevant technologies. The present study concentrated on testing and enhancing the THURIS cost model and subordinate data files and developing a technology database which interfaces directly with the user via technology readiness displays. This effort has resulted in a more powerful, easy-to-use applications system for optimization of man/machine roles. Volume 1 is an executive summary.
Water electrolysis system refurbishment and testing
NASA Technical Reports Server (NTRS)
Greenough, B. M.
1972-01-01
The electrolytic oxygen generator for the back-up water electrolysis system in a 90-day manned test was refurbished, improved and subjected to a 182-day bench test. The performance of the system during the test demonstrated the soundness of the basic electrolysis concept, the high development status of the automatic controls which allowed completely hands-off operation, and the capability for orbital operation. Some design improvements are indicated.
Capability of the Gas Analysis and Testing Laboratory at the NASA Johnson Space Center
NASA Technical Reports Server (NTRS)
Broerman, Craig; Jimenez, Javier; Sweterlitsch, Jeff
2012-01-01
The Gas Analysis and Testing Laboratory is an integral part of the testing performed at the NASA Johnson Space Center. The Gas Analysis and Testing Laboratory is a high performance laboratory providing real time analytical instruments to support manned and unmanned testing. The lab utilizes precision gas chromatographs, gas analyzers and spectrophotometers to support the technology development programs within the NASA community. The Gas Analysis and Testing Laboratory works with a wide variety of customers and provides engineering support for user-specified applications in compressed gas, chemical analysis, general and research laboratory.
Capability of the Gas Analysis and Testing Laboratory at the NASA Johnson Space Center
NASA Technical Reports Server (NTRS)
Broerman, Craig; Jimenez, Javier; Sweterlitsch, Jeff
2011-01-01
The Gas Analysis and Testing Laboratory is an integral part of the testing performed at the NASA Johnson Space Center. The Gas Analysis and Testing Laboratory is a high performance laboratory providing real time analytical instruments to support manned and unmanned testing. The lab utilizes precision gas chromatographs, gas analyzers and spectrophotometers to support the technology development programs within the NASA community. The Gas Analysis and Testing Laboratory works with a wide variety of customers and provides engineering support for user-specified applications in compressed gas, chemical analysis, general and research laboratory
Performance evaluation of candidate space suit elements for the next generation orbital EMU
NASA Technical Reports Server (NTRS)
West, Philip R.; Trausch, Stephanie V.
1992-01-01
The AX-5 all metallic, multibearing technologies developed at the Ames Research Center and the Mk III fabric and metallic technologies developed at the Johnson Space Center were evaluated using the current Space Shuttle space suit technologies as a baseline. Manned evaluations were performed in the Weightless Environment Training Facility and KC-135 zero-gravity aircraft. Joint torque, range, cycle life, and environmental protection characteristics were analyzed during unmanned tests. Both numerical results and test subject comments on performance are presented.
The freshwater amphipod Hyalella azteca is a common organism used for sediment toxicity testing in the United States and elsewhere. Standard methods for 10-d and 42-d toxicity tests with H. azteca were last revised and published by USEPA/ASTM in 2000. Under the methods in the man...
Communication Impairment in the AIDS Dementia Complex (ADC): A Case Report
ERIC Educational Resources Information Center
McCabe, Patricia J.; Sheard, Christine; Code, Chris
2008-01-01
This article details three examinations of communication impairment over 13 months in a man with AIDS dementia complex (ADC) and compares his performance on standardised language testing with that of two control participants. He had mild language impairments as measured on standardised tests but was severely impaired in pragmatic language skills.…
NASA Technical Reports Server (NTRS)
Staveland, Lowell
1994-01-01
This is the experimental and software detailed design report for the prototype task loading model (TLM) developed as part of the man-machine integration design and analysis system (MIDAS), as implemented and tested in phase 6 of the Army-NASA Aircrew/Aircraft Integration (A3I) Program. The A3I program is an exploratory development effort to advance the capabilities and use of computational representations of human performance and behavior in the design, synthesis, and analysis of manned systems. The MIDAS TLM computationally models the demands designs impose on operators to aide engineers in the conceptual design of aircraft crewstations. This report describes TLM and the results of a series of experiments which were run this phase to test its capabilities as a predictive task demand modeling tool. Specifically, it includes discussions of: the inputs and outputs of TLM, the theories underlying it, the results of the test experiments, the use of the TLM as both stand alone tool and part of a complete human operator simulation, and a brief introduction to the TLM software design.
2008-05-01
BQs ) (see Appendix B for a listing of CCOs and BQs ). The grading guidance provided direction in determining performance on a scale of 1 to 7 (table...THU FRI SAT In-Proc./ Training/ Baseline/ Testing 1/ Testing 2/ Testing 3/ Recovery/ Day 1 Day 2 Day 3 Day 4 Day 5 Day 6 Day 7 00:00 Sleep Sleep...Checklist For use of this form, see ACT Aircrew Guide CCO BQ Crew Coordination Objectives/Basic Qualities Rating I Establish and Maintain Team Relationships
Vacuum distillation/vapor filtration water recovery, phases 1 and 2
NASA Technical Reports Server (NTRS)
Honegger, R. J.; Remus, G. A.; Krug, E. K.
1973-01-01
The research is reported on the development of an evaporator for vacuum distillation/vapor filtration VD/VF water reclamation system for use on manned space flights. The design, fabrication, and tests of a six-man evaporator are described. It is concluded that: (1) A condenser with an internal rotating impeller and coolant surfaces directly opposite the condensing surfaces is an effective condenser. (2) The VD/VF evaporator, catalyst unit and condenser function satisfactorily based on thermal, mechanical and recovery performance during a 145-hour evaluation test. (3) The quality of recovered water, as measured by analyses for total organic carbon, pH, conductivity, turbidity, and viable bacteria density was within established limits for potability.
Acute suppurative parotitis caused by Streptococcus pneumoniae in an HIV-infected man.
Guzman Vinasco, Luis; Bares, Sara; Sandkovsky, Uriel
2015-03-02
We report a case of a 32-year-old man who presented with progressive unilateral parotid gland enlargement and subsequently tested positive for HIV. A CT scan of the neck performed with contrast showed a phlegmon in the region of the right parotid tail measuring approximately 2.5×2.4 cm. Cultures of the aspirated fluid grew Streptococcus pneumoniae and the S. pneumoniae urinary antigen test was also positive. The patient underwent surgical debridement and received antimicrobial therapy with complete resolution of the parotitis. Parotitis caused by S. pneumoniae is rare, and HIV infection should be suspected in any case of invasive pneumococcal disease. 2015 BMJ Publishing Group Ltd.
Acute suppurative parotitis caused by Streptococcus pneumoniae in an HIV-infected man
Guzman Vinasco, Luis; Bares, Sara; Sandkovsky, Uriel
2015-01-01
We report a case of a 32-year-old man who presented with progressive unilateral parotid gland enlargement and subsequently tested positive for HIV. A CT scan of the neck performed with contrast showed a phlegmon in the region of the right parotid tail measuring approximately 2.5×2.4 cm. Cultures of the aspirated fluid grew Streptococcus pneumoniae and the S. pneumoniae urinary antigen test was also positive. The patient underwent surgical debridement and received antimicrobial therapy with complete resolution of the parotitis. Parotitis caused by S. pneumoniae is rare, and HIV infection should be suspected in any case of invasive pneumococcal disease. PMID:25733094
42 CFR 84.101 - Man test 5; requirements.
Code of Federal Regulations, 2012 CFR
2012-10-01
... 42 Public Health 1 2012-10-01 2012-10-01 false Man test 5; requirements. 84.101 Section 84.101 Public Health PUBLIC HEALTH SERVICE, DEPARTMENT OF HEALTH AND HUMAN SERVICES OCCUPATIONAL SAFETY AND... Breathing Apparatus § 84.101 Man test 5; requirements. (a) Test 5 will be conducted to determine the maximum...
42 CFR 84.101 - Man test 5; requirements.
Code of Federal Regulations, 2014 CFR
2014-10-01
... 42 Public Health 1 2014-10-01 2014-10-01 false Man test 5; requirements. 84.101 Section 84.101 Public Health PUBLIC HEALTH SERVICE, DEPARTMENT OF HEALTH AND HUMAN SERVICES OCCUPATIONAL SAFETY AND... Breathing Apparatus § 84.101 Man test 5; requirements. (a) Test 5 will be conducted to determine the maximum...
42 CFR 84.101 - Man test 5; requirements.
Code of Federal Regulations, 2013 CFR
2013-10-01
... 42 Public Health 1 2013-10-01 2013-10-01 false Man test 5; requirements. 84.101 Section 84.101 Public Health PUBLIC HEALTH SERVICE, DEPARTMENT OF HEALTH AND HUMAN SERVICES OCCUPATIONAL SAFETY AND... Breathing Apparatus § 84.101 Man test 5; requirements. (a) Test 5 will be conducted to determine the maximum...
Code of Federal Regulations, 2011 CFR
2011-10-01
..., DEPARTMENT OF HEALTH AND HUMAN SERVICES OCCUPATIONAL SAFETY AND HEALTH RESEARCH AND RELATED ACTIVITIES...) Five minutes. Walking, turning head, dipping chin; and (2) Five minutes. Pumping air with a tire pump...
Multi-Terrain Earth Landing Systems Applicable for Manned Space Capsules
NASA Technical Reports Server (NTRS)
Fasanella, Edwin L.
2008-01-01
A key element of the President's Vision for Space Exploration is the development of a new space transportation system to replace Shuttle that will enable manned exploration of the moon, Mars, and beyond. NASA has tasked the Constellation Program with the development of this architecture, which includes the Ares launch vehicle and Orion manned spacecraft. The Orion spacecraft must carry six astronauts and its primary structure should be reusable, if practical. These requirements led the Constellation Program to consider a baseline land landing on return to earth. To assess the landing system options for Orion, a review of current operational parachute landing systems such as those used for the F-111 escape module and the Soyuz is performed. In particular, landing systems with airbags and retrorockets that would enable reusability of the Orion capsule are investigated. In addition, Apollo tests and analyses conducted in the 1960's for both water and land landings are reviewed. Finally, tests and dynamic finite element simulations to understand land landings for the Orion spacecraft are also presented.
NASA Technical Reports Server (NTRS)
Edeen, Marybeth; Henninger, Donald
1991-01-01
By growing higher plants for food, lunar and Martian manned habitats will not only reduce resupply requirements but obtain CO2 removal and both oxygen-production and water-reclamation requirements. Plants have been grown in the RLSS at NASA-Johnson in order to quantitatively evaluate plant CO2 accumulation, O2 generation, evapotranspiration, trace-contaminant generation, and biomass productivity. Attention is presently given to test conditions and anomalies in these RLSS trials; areas where performance must be improved have been identified.
42 CFR 84.102 - Man test 6; requirements.
Code of Federal Regulations, 2010 CFR
2010-10-01
... 42 Public Health 1 2010-10-01 2010-10-01 false Man test 6; requirements. 84.102 Section 84.102 Public Health PUBLIC HEALTH SERVICE, DEPARTMENT OF HEALTH AND HUMAN SERVICES OCCUPATIONAL SAFETY AND HEALTH RESEARCH AND RELATED ACTIVITIES APPROVAL OF RESPIRATORY PROTECTIVE DEVICES Self-Contained Breathing Apparatus § 84.102 Man test 6; requirements....
42 CFR 84.101 - Man test 5; requirements.
Code of Federal Regulations, 2010 CFR
2010-10-01
... 42 Public Health 1 2010-10-01 2010-10-01 false Man test 5; requirements. 84.101 Section 84.101 Public Health PUBLIC HEALTH SERVICE, DEPARTMENT OF HEALTH AND HUMAN SERVICES OCCUPATIONAL SAFETY AND HEALTH RESEARCH AND RELATED ACTIVITIES APPROVAL OF RESPIRATORY PROTECTIVE DEVICES Self-Contained Breathing Apparatus § 84.101 Man test 5; requirements....
Validation of NHB 8060.1C, Test 18 Arc Tracking, September 30, 1991
NASA Technical Reports Server (NTRS)
Linley, Larry
2005-01-01
A test project was conducted to validate Test 18 of NASA Handbook (NHB) 8060.1C and, if necessary, identify and recommend improvements in the procedures or criteria of the test. The NHB 8060.1C, Test 18 test system was modified to produce better discrimination of test results. Changes, and their effects on test results, in the graphite immersion-depth, test timing sequence, and atmospheric conditions were investigated for the wire-insulation constructions tested. Based on the test results, the graphite immersion-depths (between 0.8 mm and 1.6 mm), the timing sequence, and the change in the test conditions from ambient to three environments common in manned spaceflight did not significantly affect test results. The criteria used in Test 18 of NHB 8060.1C was found to be appropriate for qualifying arc-tracking and arc-propagation characteristics of wire-insulation materials, Using the Test 18 criteria, Kapton and ETFE were considered inappropriate for use, while PTFE was considered appropriate. Recommendations from this test project for Test 18 of NHB 8060.1C include changing the experimental setup and configurational tests and performing qualification testing in air rather than in the three environments common in manned spaceflight.
NASA Technical Reports Server (NTRS)
Tri, Terry O.; Thompson, Clifford D.
1992-01-01
Future NASA manned missions to the moon and Mars will require development of robust regenerative life support system technologies which offer high reliability and minimal resupply. To support the development of such systems, early ground-based test facilities will be required to demonstrate integrated, long-duration performance of candidate regenerative air revitalization, water recovery, and thermal management systems. The advanced life support Systems Integration Research Facility (SIRF) is one such test facility currently being developed at NASA's Johnson Space Center. The SIRF, when completed, will accommodate unmanned and subsequently manned integrated testing of advanced regenerative life support technologies at ambient and reduced atmospheric pressures. This paper provides an overview of the SIRF project, a top-level description of test facilities to support the project, conceptual illustrations of integrated test article configurations for each of the three SIRF systems, and a phased project schedule denoting projected activities and milestones through the next several years.
Code of Federal Regulations, 2011 CFR
2011-10-01
... 42 Public Health 1 2011-10-01 2011-10-01 false Man test for gases and vapors; Type C respirators, continuous-flow class and Type CE supplied-air respirators; test requirements. 84.162 Section 84.162 Public....162 Man test for gases and vapors; Type C respirators, continuous-flow class and Type CE supplied-air...
Code of Federal Regulations, 2014 CFR
2014-10-01
... 42 Public Health 1 2014-10-01 2014-10-01 false Man test for gases and vapors; Type C respirators, continuous-flow class and Type CE supplied-air respirators; test requirements. 84.162 Section 84.162 Public....162 Man test for gases and vapors; Type C respirators, continuous-flow class and Type CE supplied-air...
Code of Federal Regulations, 2013 CFR
2013-10-01
... 42 Public Health 1 2013-10-01 2013-10-01 false Man test for gases and vapors; Type C respirators, continuous-flow class and Type CE supplied-air respirators; test requirements. 84.162 Section 84.162 Public....162 Man test for gases and vapors; Type C respirators, continuous-flow class and Type CE supplied-air...
Code of Federal Regulations, 2012 CFR
2012-10-01
... 42 Public Health 1 2012-10-01 2012-10-01 false Man test for gases and vapors; Type C respirators, continuous-flow class and Type CE supplied-air respirators; test requirements. 84.162 Section 84.162 Public....162 Man test for gases and vapors; Type C respirators, continuous-flow class and Type CE supplied-air...
A new TaqMan method for the reliable diagnosis of Ehrlichia spp. in canine whole blood.
Thomson, Kirsty; Yaaran, Tal; Belshaw, Alex; Curson, Lucia; Tisi, Laurence; Maurice, Sarah; Kiddle, Guy
2018-06-18
Ehrlichiosis is an important emerging infectious disease of the canid family and humans worldwide. To date, no extensive evaluation or validation of a molecular diagnostic test for ehrlichiosis has been published. Here, we present data for a newly designed TaqMan assay and compare its performance to a commercial technology (PCRun®). Both of these real-time methods of analysis were evaluated using a comprehensive number of prospective and retrospective samples collected from dogs exhibiting symptoms of ehrlichiosis. Whole blood samples collected from dogs, retrospectively in the United Kingdom and prospectively in Israel, were analysed for the presence of Ehrlichia canis and Ehrlichia minasensis DNA using the TaqMan PCR, developed specifically for this study. The results were compared to those of a real time commercial isothermal amplification method (PCRun® system developed by Biogal Galed Labs ACS, Galed, Israel). The sensitivity and specificity (CI: 95%) of the TaqMan PCR and PCRun® were both determined to be 100% and absolute, for all of the samples tested. Interestingly, both tests were demonstrated to be highly comparable, irrespective of differences in amplification chemistry or sequences targeted. Host differences, incidence of disease and geographical location of the isolates had little impact on the positivity recorded by each of the diagnostic methods. It was evident that both amplification methods were equally suited for diagnosing canine ehrlichiosis and while the PCRun® clearly amplified all clinically relevant Ehrlichia species known to infect dogs and humans, the TaqMan method was more specific for E. canis and E. minasensis. This work demonstrates that despite good analytical sensitivities and specificities for Ehrlichia spp. neither method could fully account for the clinical diagnosis of thrombocytopenia.
Carleton, Stephanie M.; Peck, Dawn S.; Grasela, Julie; Dietiker, Kristin L.
2010-01-01
Maple syrup urine disease (MSUD) is an inherited metabolic disorder caused by mutations in the branched chain α-keto acid dehydrogenase complex. Worldwide incidence of MSUD is 1:225,000 live births. However, within Old Order Mennonite communities, the incidence is 1:150 live births and results from a common tyrosine to asparagine substitution (Y438N) in the E1α subunit of branched chain α-keto acid dehydrogenase. We developed a new DNA diagnostic assay utilizing TaqMan® technology and compared its efficacy, sensitivity, and duration with an existing polymerase chain reaction–restriction fragment length polymorphism (PCR-RFLP) assay. Carrier testing was performed by both TaqMan technology and PCR-RFLP on DNA isolated from buccal swabs of 160 individuals as well as from buccal swabs and blood spots of nine at-risk newborns; assay time, sensitivity, and reliability were also evaluated. The TaqMan assay, like the PCR-RFLP assay, accurately determined Y438N E1α allele status. However, the TaqMan assay appeared (1) more sensitive than the PCR-RFLP assay, requiring 10-fold less DNA (10 ng) to reliably determine genotype status and (2) faster, reducing the assay time required for diagnosis from ∼12 to 5 h. TaqMan technology allowed more rapid DNA diagnoses of MSUD in the neonate, thereby reducing the likelihood of neurological impairment while enhancing health and prognosis for affected infants. PMID:20136525
42 CFR 84.100 - Man tests 1, 2, 3, and 4; requirements.
Code of Federal Regulations, 2010 CFR
2010-10-01
... 42 Public Health 1 2010-10-01 2010-10-01 false Man tests 1, 2, 3, and 4; requirements. 84.100 Section 84.100 Public Health PUBLIC HEALTH SERVICE, DEPARTMENT OF HEALTH AND HUMAN SERVICES OCCUPATIONAL SAFETY AND HEALTH RESEARCH AND RELATED ACTIVITIES APPROVAL OF RESPIRATORY PROTECTIVE DEVICES Self-Contained Breathing Apparatus § 84.100 Man tests 1...
Salvi, Sergio; D'Orso, Fabio; Morelli, Giorgio
2008-06-25
Many countries have introduced mandatory labeling requirements on foods derived from genetically modified organisms (GMOs). Real-time quantitative polymerase chain reaction (PCR) based upon the TaqMan probe chemistry has become the method mostly used to support these regulations; moreover, event-specific PCR is the preferred method in GMO detection because of its high specificity based on the flanking sequence of the exogenous integrant. The aim of this study was to evaluate the use of very short (eight-nucleotide long), locked nucleic acid (LNA) TaqMan probes in 5'-nuclease PCR assays for the detection and quantification of GMOs. Classic TaqMan and LNA TaqMan probes were compared for the analysis of the maize MON810 transgene. The performance of the two types of probes was tested on the maize endogenous reference gene hmga, the CaMV 35S promoter, and the hsp70/cryIA(b) construct as well as for the event-specific 5'-integration junction of MON810, using plasmids as standard reference molecules. The results of our study demonstrate that the LNA 5'-nuclease PCR assays represent a valid and reliable analytical system for the detection and quantification of transgenes. Application of very short LNA TaqMan probes to GMO quantification can simplify the design of 5'-nuclease assays.
NASA Technical Reports Server (NTRS)
1979-01-01
A manned remote work station (MRWS) mission scenario, broken down into the three time phases was selected as the basis for analysis of the MRWS flight article requirements and concepts. The mission roles for the three time phases, supporting tradeoff and evaluation studies, was used to identify key issues requiring simulation. The MRWS is discussed in terms of its capability to perform such operations as support of Spacelab experiments, servicing and repair of satellites, and construction. Future considerations for the use of the MRWS are also given.
Apollo 8 Astronaut Anders Suits Up For Countdown Demonstration Test
NASA Technical Reports Server (NTRS)
1968-01-01
Apollo 8 astronaut William Anders, Lunar Module (LM) pilot, is suited up for the Apollo 8 mission countdown demonstration test. The first manned Apollo mission launched aboard the Saturn V and first manned Apollo craft to enter lunar orbit, the SA-503, Apollo 8 mission lift off occurred on December 21, 1968 and returned safely to Earth on December 27, 1968. Aboard were Anders and fellow astronauts James Lovell, Command Module (CM) pilot; and Frank Borman, commander. The mission achieved operational experience and tested the Apollo command module systems, including communications, tracking, and life-support, in cis-lunar space and lunar orbit, and allowed evaluation of crew performance on a lunar orbiting mission. The crew photographed the lunar surface, both far side and near side, obtaining information on topography and landmarks as well as other scientific information necessary for future Apollo landings. All systems operated within allowable parameters and all objectives of the mission were achieved.
NASA Technical Reports Server (NTRS)
Fields, S. F.; Labak, L. J.; Honegger, R. J.
1974-01-01
A baseline laboratory prototype of an integrated, six man, zero-g subsystem for processing human wastes onboard spacecraft was investigated, and included the development of an operational specification for the baseline subsystem, followed by design and fabrication. The program was concluded by performing a series of six tests over a period of two weeks to evaluate the performance of the subsystem. The results of the tests were satisfactory, however, several changes in the design of the subsystem are required before completely satisfactory performance can be achieved.
Extended testing of compression distillation.
NASA Technical Reports Server (NTRS)
Bambenek, R. A.; Nuccio, P. P.
1972-01-01
During the past eight years, the NASA Manned Spacecraft Center has supported the development of an integrated water and waste management system which includes the compression distillation process for recovering useable water from urine, urinal flush water, humidity condensate, commode flush water, and concentrated wash water. This paper describes the design of the compression distillation unit, developed for this system, and the testing performed to demonstrate its reliability and performance. In addition, this paper summarizes the work performed on pretreatment and post-treatment processes, to assure the recovery of sterile potable water from urine and treated urinal flush water.
United Space Alliance waits to test its one-man submarine for SRB retrieval
NASA Technical Reports Server (NTRS)
2000-01-01
The one-man submarine dubbed DeepWorker 2000 sits on the deck of Liberty Star, one of two KSC solid rocket booster recovery ships. The sub is being tested on its ability to duplicate the sometimes hazardous job United Space Alliance (USA) divers perform to recover the expended boosters in the ocean after a launch. The boosters splash down in an impact area about 140 miles east of Jacksonville and after recovery are towed back to KSC for refurbishment by the specially rigged recovery ships. DeepWorker 2000 was built by Nuytco Research Ltd., North Vancouver, British Columbia. It is 8.25 feet long, 5.75 feet high, and weighs 3,800 pounds. USA is a prime contractor to NASA for the Space Shuttle program.
Time/Frequency Relationships for an FFT-Based Acoustic Modem
2010-09-01
Jenkins II 5. FUNDING NUMBERS 7. PERFORMING ORGANIZATION NAME(S) AND ADDRESS(ES) Naval Postgraduate School Monterey, CA 93943-5000 8. PERFORMING... seawater , and a fluid- like bottom composed of quartz sand. From [11] ............................................18 Table 3. Transmission loss at the...in St. Andrew’s Bay, Florida [4]. The goal of this sea testing was to observe the effects of natural and man-made noise on network performance in a
Test results of six-month test of two water electrolysis systems
NASA Technical Reports Server (NTRS)
Mills, E. S.; Wells, G. W.
1972-01-01
The two water electrolysis systems used in the NASA space station simulation 90-day manned test of a regenerative life support system were refurbished as required and subjected to 26-weeks of testing. The two electrolysis units are both promising systems for oxygen and hydrogen generation and both needed extensive long-term testing to evaluate the performance of the respective cell design and provide guidance for further development. Testing was conducted to evaluate performance in terms of current, pressure, variable oxygen demands, and orbital simulation. An automatic monitoring system was used to record, monitor and printout performance data at one minute, ten minute or one-hour intervals. Performance data is presented for each day of system operation for each module used during the day. Failures are analyzed, remedial action taken to eliminate problems is discussed and recommendations for redesign for future space applications are stated.
SSI-ARC Flight Test 3 Data Review
NASA Technical Reports Server (NTRS)
Gong, Chester; Wu, Minghong G.
2015-01-01
The "Unmanned Aircraft System (UAS) Integration into the National Airspace System (NAS)" Project conducted flight test program, referred to as Flight Test 3, at Armstrong Flight Research Center from June - August 2015. Four flight test days were dedicated to the NASA Ames-developed Detect and Avoid (DAA) System referred to as Autoresolver. The encounter scenarios, which involved NASA's Ikhana UAS and a manned intruder aircraft, were designed to collect data on DAA system performance in real-world conditions and uncertainties with four different surveillance sensor systems. Resulting flight test data and analysis results will be used to evaluate the DAA system performance (e.g., trajectory prediction accuracy, threat detection) and to add fidelity to simulation models used to inform Minimum Operating Performance Standards (MOPS) for integrating UAS into routine NAS operations.
Multi-Terrain Earth Landing Systems Applicable for Manned Space Capsules
NASA Technical Reports Server (NTRS)
Fasanella, Edwin L.
2008-01-01
A key element of the President's Vision for Space Exploration is the development of a new space transportation system to replace the Shuttle that will enable manned exploration of the moon, Mars, and beyond. NASA has tasked the Constellation Program with the development of this architecture, which includes the Ares launch vehicle and Orion manned spacecraft. The Orion spacecraft must carry six astronauts and its primary structure should be reusable, if practical. These requirements led the Constellation Program to consider a baseline land landing on return to earth. To assess the landing system options for Orion, a review of current operational parachute landing systems such as those used for the F-111 escape module and the Soyuz is performed. In particular, landing systems with airbags and retrorockets that would enable reusability of the Orion capsule are investigated. In addition, Apollo tests and analyses conducted in the 1960's for both water and land landings are reviewed. Finally, tests and dynamic finite element simulations to understand land landings for the Orion spacecraft are also presented.
Continuous performance measurement in flight systems. [sequential control model
NASA Technical Reports Server (NTRS)
Connelly, E. M.; Sloan, N. A.; Zeskind, R. M.
1975-01-01
The desired response of many man machine control systems can be formulated as a solution to an optimal control synthesis problem where the cost index is given and the resulting optimal trajectories correspond to the desired trajectories of the man machine system. Optimal control synthesis provides the reference criteria and the significance of error information required for performance measurement. The synthesis procedure described provides a continuous performance measure (CPM) which is independent of the mechanism generating the control action. Therefore, the technique provides a meaningful method for online evaluation of man's control capability in terms of total man machine performance.
The Apollo spacecraft: A chronology, volume 3, 1 October 1964 - 20 January 1966
NASA Technical Reports Server (NTRS)
Brooks, C. G.; Ertel, I. D.
1976-01-01
The development of the Apollo spacecraft is traced along with that of Saturn V. Emphasis is placed on the detailed engineering design and exhaustive testing performed to qualify both the command and service modules and the lunar module for manned flight.
The PMS project: Poor man's supercomputer
NASA Astrophysics Data System (ADS)
Csikor, F.; Fodor, Z.; Hegedüs, P.; Horváth, V. K.; Katz, S. D.; Piróth, A.
2001-02-01
We briefly describe the Poor Man's Supercomputer (PMS) project carried out at Eötvös University, Budapest. The goal was to construct a cost effective, scalable, fast parallel computer to perform numerical calculations of physical problems that can be implemented on a lattice with nearest neighbour interactions. To this end we developed the PMS architecture using PC components and designed a special, low cost communication hardware and the driver software for Linux OS. Our first implementation of PMS includes 32 nodes (PMS1). The performance of PMS1 was tested by Lattice Gauge Theory simulations. Using pure SU(3) gauge theory or the bosonic part of the minimal supersymmetric extention of the standard model (MSSM) on PMS1 we obtained 3 / Mflops and 0.60 / Mflops price-to-sustained performance ratio for double and single precision operations, respectively. The design of the special hardware and the communication driver are freely available upon request for non-profit organizations.
NASA Technical Reports Server (NTRS)
Kostell, G. D.; Schubert, F. H.; Shumar, J. W.; Hallick, T. M.; Jensen, F. C.
1974-01-01
A six man, self contained, electrochemical carbon dioxide concentrating subsystem for space station prototype use was successfully designed, fabricated, and tested. A test program was successfully completed which covered shakedown testing, design verification testing, and acceptance testing.
NASA Technical Reports Server (NTRS)
Wright, R. M.; Hwang, K. C.
1973-01-01
The sorbent behavior of solid amine resin IR-45 with regard to potential use in regenerative CO2-removal systems for manned spacecraft is considered. Measurements of equilibrium sorption capacity of IR-45 for water and for CO2 are reported, and the dynamic mass transfer behavior of IR-45 beds is studied under conditions representative of those expected in a manned spacecraft. A digital computer program was written for the transient performance prediction of CO2 removal systems comprised of solid amine beds. Also evaluated are systems employing inorganic molecular-sieve sorbents. Tests show that there is definitely an effect of water loading on the absorption rate.
ERIC Educational Resources Information Center
Kessels, Ursula; Steinmayr, Ricarda
2013-01-01
This study seeks to understand boys' lower academic success by analysing the relationship between sex, gender role self-concept, help seeking attitudes, and school performance in a sample of 182 German 11th grade students (83 girls, 99 boys), age 16. Grades at two points in time, intelligence test data, help-seeking attitudes, gender role…
Schønning, Kristian; Johansen, Kim; Nielsen, Lone Gilmor; Weis, Nina; Westh, Henrik
2018-07-01
Quantification of HBV DNA is used for initiating and monitoring antiviral treatment. Analytical test performance consequently impacts treatment decisions. To compare the analytical performance of the Aptima HBV Quant Assay (Aptima) and the COBAS Ampliprep/COBAS TaqMan HBV Test v2.0 (CAPCTMv2) for the quantification of HBV DNA in plasma samples. The performance of the two tests was compared on 129 prospective plasma samples, and on 63 archived plasma samples of which 53 were genotyped. Linearity of the two assays was assessed on dilutions series of three clinical samples (Genotype B, C, and D). Bland-Altman analysis of 120 clinical samples, which quantified in both tests, showed an average quantification bias (Aptima - CAPCTMv2) of -0.19 Log IU/mL (SD: 0.33 Log IU/mL). A single sample quantified more than three standard deviations higher in Aptima than in CAPCTMv2. Only minor differences were observed between genotype A (N = 4; average difference -0.01 Log IU/mL), B (N = 8; -0.13 Log IU/mL), C (N = 8; -0.31 Log IU/mL), D (N = 25; -0.22 Log IU/mL), and E (N = 7; -0.03 Log IU/mL). Deming regression showed that the two tests were excellently correlated (slope of the regression line 1.03; 95% CI: 0.998-1.068). Linearity of the tests was evaluated on dilution series and showed an excellent correlation of the two tests. Both tests were precise with %CV less than 3% for HBV DNA ≥3 Log IU/mL. The Aptima and CAPCTMv2 tests are highly correlated, and both tests are useful for monitoring patients chronically infected with HBV. Copyright © 2018 Elsevier B.V. All rights reserved.
Schønning, Kristian; Johansen, Kim; Landt, Bodil; Benfield, Thomas; Westh, Henrik
2017-07-01
HIV-RNA is the most important parameter for monitoring antiviral treatment in individuals infected with HIV-1. Knowledge of the performance of different tests for the quantification of HIV-1 RNA is therefore important for clinical care. To compare the analytical performance of the Aptima HIV-1 Quant Dx Assay (Aptima) and the COBAS Ampliprep/COBAS TaqMan HIV-1 Test v2.0 (CAPCTMv2) for the quantification of HIV-1 RNA in plasma samples. The performance of the two tests was compared on 216 clinical plasma samples, on dilutions series in seven replicates of five clinical samples of known subtype and on ten replicates of the Acrometrix High and Low Positive Control. Bland-Altman analysis of 130 samples that quantified in both tests did not show indications of gross mis-quantification of either test. A tendency of the Aptima assay to quantify higher at high viral load compared to the CAPCTMv2 was observed in Bland-Altman analysis, by Deming regression (Slope 1.13) and in dilution series of clinical samples. Precision evaluated using the Acrometrix Positive Controls was similar for the High Control (CV: 1.2% vs. 1.3%; Aptima assay vs. CAPCTMv2 test, respectively), but differed for the Low control (CV: 17.9% vs. 7.1%; Aptima assay vs. CAPCTMv2 test, respectively). However, this did not impact clinical categorization of clinical samples at neither the 50 cp/mL nor 200 cp/mL level. The Aptima assay and the CAPCTMv2 test are highly correlated and are useful for monitoring HIV-infected individuals. Copyright © 2017 Elsevier B.V. All rights reserved.
Environment, power, and society. [stressing energy language and energy analysis
DOE Office of Scientific and Technical Information (OSTI.GOV)
Odum, H.T.
Studies of the energetics of ecological systems suggest general means for applying basic laws of energy and matter to the complex systems of nature and man. In this book, energy language is used to consider the pressing problem of survival in our time--the partnership of man in nature. An effort is made to show that energy analysis can help answer many of the questions of economics, law, and religion. Models for the analysis of a system are made by recognizing major divisions whose causal relationships are indicated by the pathways of interchange of energy and work. Then simulation allows themore » model's performance to be tested against the performance of the real system. Ideal energy flows are illustrated with ecological systems and then applied to all kinds of situations from very small biochemical processes to the large overall systems of man and the biosphere. Energy diagraming is included to consider the great problems of power, pollution, population, food, and war. This account also attempts to introduce ecology through the energy language.« less
Enzyme Mini-Test for Field Identification of Leishmania Isolates from U.S. Military Personnel.
1986-05-15
Panama Dominques L2 539 NWC LBP Man - Panama Carillo 530 NWC LBP Man - Panama Schoonmaker 063 NWC LBG Man - Peru Terborgh/Muco 294 NWC LBB Man - Brazil...NWC LMA-G Man - Panama Castro 140 NWC LMM-P Man - Peru UTA 381 NWC LMM-P Man - Panama Peters 453 NWC LMM-P Man - Dominican Republic - 457 NWC LMM-P...LV24 547 OWC LMJ Man R. Beach Kenya LRC-L137 551 OWC LMJ Rodent R. Beach Kenya NLB095 552 OWC LMJ Sandfly R. Beach Kenya NLBI44 558 OWC LMJ Man
Urine sampling and collection system
NASA Technical Reports Server (NTRS)
Fogal, G. L.; Mangialardi, J. K.; Reinhardt, C. G.
1971-01-01
This specification defines the performance and design requirements for the urine sampling and collection system engineering model and establishes requirements for its design, development, and test. The model shall provide conceptual verification of a system applicable to manned space flight which will automatically provide for collection, volume sensing, and sampling of urine.
Z-2 Architecture Description and Requirements Verification Results
NASA Technical Reports Server (NTRS)
Graziosi, Dave; Jones, Bobby; Ferl, Jinny; Scarborough, Steve; Hewes, Linda; Ross, Amy; Rhodes, Richard
2016-01-01
The Z-2 Prototype Planetary Extravehicular Space Suit Assembly is a continuation of NASA's Z series of spacesuits. The Z-2 is another step in NASA's technology development roadmap leading to human exploration of the Martian surface. The suit was designed for maximum mobility at 8.3 psid, reduced mass, and to have high fidelity life support interfaces. As Z-2 will be man-tested at full vacuum in NASA JSC's Chamber B, it was manufactured as Class II, making it the most flight-like planetary walking suit produced to date. The Z-2 suit architecture is an evolution of previous EVA suits, namely the ISS EMU, Mark III, Rear Entry I-Suit and Z-1 spacesuits. The suit is a hybrid hard and soft multi-bearing, rear entry spacesuit. The hard upper torso (HUT) is an all-composite structure and includes a 2-bearing rolling convolute shoulder with Vernier sizing mechanism, removable suit port interface plate (SIP), elliptical hemispherical helmet and self-don/doff shoulder harness. The hatch is a hybrid aluminum and composite construction with Apollo style gas connectors, custom water pass-thru, removable hatch cage and interfaces to primary and auxiliary life support feed water bags. The suit includes Z-1 style lower arms with cam brackets for Vernier sizing and government furnished equipment (GFE) Phase VI gloves. The lower torso includes a telescopic waist sizing system, waist bearing, rolling convolute waist joint, hard brief, 2 bearing soft hip thigh, Z-1 style legs with ISS EMU style cam brackets for sizing, and conformal walking boots with ankle bearings. The Z-2 Requirements Verification Plan includes the verification of more than 200 individual requirements. The verification methods include test, analysis, inspection, demonstration or a combination of methods. Examples of unmanned requirements include suit leakage, proof pressure testing, operational life, mass, isometric man-loads, sizing adjustment ranges, internal and external interfaces such as in-suit drink bag, partial pressure relief valve, purge valve, donning stand and ISS Body Restraint Tether (BRT). Examples of manned requirements include verification of anthropometric range, suit self-don/doff, secondary suit exit method, donning stand self-ingress/egress and manned mobility covering eight functional tasks. The eight functional tasks include kneeling with object pick-up, standing toe touch, cross-body reach, walking, reach to the SIP and helmet visor. This paper will provide an overview of the Z-2 design. Z-2 requirements verification testing was performed with NASA at the ILC Houston test facility. This paper will also discuss pre-delivery manned and unmanned test results as well as analysis performed in support of requirements verification.
NASA Technical Reports Server (NTRS)
Genin, A. M.
1980-01-01
Various tests related to studies concerning the effects of decompression sicknesses at varying pressure levels and physical activity are described. The tests indicate that there are no guarantees of freedom from decompression sicknesses when man transitions from a normally oxygenated normobaric nitrogen-oxygen atmosphere into an environment having a 0.4 atm or lower pressure and he is performing physical work.
Schalasta, Gunnar; Börner, Anna; Speicher, Andrea; Enders, Martin
2016-03-01
Quantification of human immunodeficiency virus type 1 (HIV-1) RNA in plasma has become the standard of care in the management of HIV-infected patients. There are several commercially available assays that have been implemented for the detection of HIV-1 RNA in plasma. Here, the new Hologic Aptima® HIV-1 Quant Dx assay (Aptima HIV) was compared to the Roche COBAS® TaqMan® HIV-1 Test v2.0 for use with the High Pure System (HPS/CTM). The performance characteristics of the assays were assessed using commercially available HIV reference panels, dilution of the WHO 3rd International HIV-1 RNA International Standard (WHO-IS) and plasma from clinical specimens. Assay performance was determined by linear regression, Deming correlation analysis and Bland-Altman analysis. Testing of HIV-1 reference panels revealed excellent agreement. The 61 clinical specimens quantified in both assays were linearly associated and strongly correlated. The Aptima HIV assay offers performance comparable to that of the HPS/CTM assay and, as it is run on a fully automated platform, a significantly improved workflow.
Differential GPS/inertial navigation approach/landing flight test results
NASA Technical Reports Server (NTRS)
Snyder, Scott; Schipper, Brian; Vallot, Larry; Parker, Nigel; Spitzer, Cary
1992-01-01
Results of a joint Honeywell/NASA-Langley differential GPS/inertial flight test conducted in November 1990 are discussed focusing on postflight data analysis. The test was aimed at acquiring a system performance database and demonstrating automatic landing based on an integrated differential GPS/INS with barometric and radar altimeters. Particular attention is given to characteristics of DGPS/inertial error and the magnitude of the differential corrections and vertical channel performance with and without altimeter augmentation. It is shown that DGPS/inertial integrated with a radar altimeter is capable of providing a precision approach and autoland guidance of manned return space vehicles within the Space Shuttle accuracy requirements.
Angiographic Anatomy of External Iliac Arteries in the Sheep.
Joscht, M; Martin, M; Henin, M; Nisolle, J F; Kirschvink, N; Dugdale, A; Godart, B; Coulon, H; Simon, V; Hontoir, F; Graffin, R; De Raeve, Y; Vandeweerd, J M
2016-12-01
External iliac artery atherosclerotic disease and aneurism occur in man. For treatment, imaging is required to facilitate minimally invasive introduction and advancement of stents within the intended vessels. Sheep are commonly used to test and improve stents. However, little information is published regarding the angiographic anatomy of the iliac arteries in the ovine species. The objective of this study was to describe the angiographic anatomy of the iliac arteries in the sheep. Computed tomography (CT) angiography and gross anatomical dissection were performed in, respectively, 10 and 43 adult ewes. Diameters and lengths of the arteries were measured. In comparison with man, salient anatomical differences were identified in the sheep: (1) the absence of common iliac arteries, (2) the common trunk at the origin of internal iliac arteries and (3) the location of the bifurcation of the external iliac arteries into femoral arteries in the pelvis (not in the limb). External iliac arteries in this series of sheep were 86 mm long in average and had a mean diameter of 7.5 mm. Lengths of arteries are only slightly different between man and sheep, while diameters are rather similar. Therefore, the sheep model appears to be sufficiently similar to man to test stent properties. This study provides useful reference images and measures of lengths and diameters of relevant arteries that could be applied to research with ovine models. © 2015 Blackwell Verlag GmbH.
Yakami, Yoshikazu; Watanabe, Kenji; Kameda, Natsuhiko; Machida, Hirohisa; Okazaki, Hirotoshi; Yamagami, Hirokazu; Shiba, Masatsugu; Fujiwara, Yasuhiro; Oshitani, Nobuhide; Arakawa, Tetsuo
2008-11-01
A 31-year-old man has visited our hospital, complaining diarrhea and leg edema. Blood test showed hypoalbuminea, but we couldn't find the reason by several examinations. Therefore, we performed double balloon enteroscopy, and intestinal lymphangiectasia was diagnosed histologically by biopsy. It's useful and effective to perform double balloon enteroscopy and histological examination for the unknown origin case of protein loosing enteropathy.
United Space Alliance waits to test its one-man submarine for SRB retrieval
NASA Technical Reports Server (NTRS)
2000-01-01
The one-man submarine dubbed DeepWorker 2000 sits on the deck of Liberty Star, one of two KSC solid rocket booster recovery ships. Inside the sub is the pilot, Anker Rasmussen. The sub is being tested on its ability to duplicate the sometimes hazardous job United Space Alliance (USA) divers perform to recover the expended boosters in the ocean after a launch. The boosters splash down in an impact area about 140 miles east of Jacksonville and after recovery are towed back to KSC for refurbishment by the specially rigged recovery ships. DeepWorker 2000 was built by Nuytco Research Ltd., North Vancouver, British Columbia. It is 8.25 feet long, 5.75 feet high, and weighs 3,800 pounds. USA is a prime contractor to NASA for the Space Shuttle program.
Human capabilities in space. [man machine interaction
NASA Technical Reports Server (NTRS)
Nicogossian, A. E.
1984-01-01
Man's ability to live and perform useful work in space was demonstrated throughout the history of manned space flight. Current planning envisions a multi-functional space station. Man's unique abilities to respond to the unforeseen and to operate at a level of complexity exceeding any reasonable amount of previous planning distinguish him from present day machines. His limitations, however, include his inherent inability to survive without protection, his limited strength, and his propensity to make mistakes when performing repetitive and monotonous tasks. By contrast, an automated system does routine and delicate tasks, exerts force smoothly and precisely, stores, and recalls large amounts of data, and performs deductive reasoning while maintaining a relative insensitivity to the environment. The establishment of a permanent presence of man in space demands that man and machines be appropriately combined in spaceborne systems. To achieve this optimal combination, research is needed in such diverse fields as artificial intelligence, robotics, behavioral psychology, economics, and human factors engineering.
Apollo experience report: Manned thermal-vacuum testing of spacecraft
NASA Technical Reports Server (NTRS)
Mclane, J. C., Jr.
1974-01-01
Manned thermal-vacuum tests of the Apollo spacecraft presented many first-time problems in the areas of test philosophy, operational concepts, and program implementation. The rationale used to resolve these problems is explained and examined critically in view of actual experience. The series of 12 tests involving 1517 hours of chamber operating time resulted in the disclosure of numerous equipment and procedural deficiencies of significance to the flight mission. Test experience and results in view of subsequent flight experience confirmed that thermal-vacuum testing of integrated manned spacecraft provides a feasible, cost-effective, and safe technique with which to obtain maximum confidence in spacecraft flight worthiness early in the program.
Kho, S L; Chua, K H; George, E; Tan, J A M A
2013-07-15
Beta-thalassemia is a life-threatening inherited blood disorder. Rapid characterization of β-globin gene mutations is necessary because of the high frequency of Malaysian β-thalassemia carriers. A combination real-time polymerase chain reaction genotyping assay using TaqMan probes was developed to confirm β-globin gene mutations. In this study, primers and probes were designed to specifically identify 8 common β-thalassemia mutations in the Malaysian Malay and Chinese ethnic groups using the Primer Express software. "Blind tests" using DNA samples from healthy individuals and β-thalassemia patients with different genotypes were performed to determine the specificity and sensitivity of this newly designed assay. Our results showed 100% sensitivity and specificity for this novel assay. In conclusion, the TaqMan genotyping assay is a straightforward assay that allows detection of β-globin gene mutations in less than 40 min. The simplicity and reproducibility of the TaqMan genotyping assay permit its use in laboratories as a rapid and cost-effective diagnostic tool for confirmation of common β-thalassemia mutations in Malaysia.
Kim, Hyerin; Kang, NaNa; An, KyuHyeon; Koo, JaeHyung; Kim, Min-Soo
2016-01-01
Design of high-quality primers for multiple target sequences is essential for qPCR experiments, but is challenging due to the need to consider both homology tests on off-target sequences and the same stringent filtering constraints on the primers. Existing web servers for primer design have major drawbacks, including requiring the use of BLAST-like tools for homology tests, lack of support for ranking of primers, TaqMan probes and simultaneous design of primers against multiple targets. Due to the large-scale computational overhead, the few web servers supporting homology tests use heuristic approaches or perform homology tests within a limited scope. Here, we describe the MRPrimerW, which performs complete homology testing, supports batch design of primers for multi-target qPCR experiments, supports design of TaqMan probes and ranks the resulting primers to return the top-1 best primers to the user. To ensure high accuracy, we adopted the core algorithm of a previously reported MapReduce-based method, MRPrimer, but completely redesigned it to allow users to receive query results quickly in a web interface, without requiring a MapReduce cluster or a long computation. MRPrimerW provides primer design services and a complete set of 341 963 135 in silico validated primers covering 99% of human and mouse genes. Free access: http://MRPrimerW.com. PMID:27154272
Schalasta, Gunnar; Börner, Anna; Speicher, Andrea; Enders, Martin
2018-03-28
Proper management of patients with chronic hepatitis B virus (HBV) infection requires monitoring of plasma or serum HBV DNA levels using a highly sensitive nucleic acid amplification test. Because commercially available assays differ in performance, we compared herein the performance of the Hologic Aptima HBV Quant assay (Aptima) to that of the Roche Cobas TaqMan HBV test for use with the high pure system (HPS/CTM). Assay performance was assessed using HBV reference panels as well as plasma and serum samples from chronically HBV-infected patients. Method correlation, analytical sensitivity, precision/reproducibility, linearity, bias and influence of genotype were evaluated. Data analysis was performed using linear regression, Deming correlation analysis and Bland-Altman analysis. Agreement between the assays for the two reference panels was good, with a difference in assay values vs. target <0.5 log. Qualitative assay results for 159 clinical samples showed good concordance (88.1%; κ=0.75; 95% confidence interval: 0.651-0.845). For the 106 samples quantitated by both assays, viral load results were highly correlated (R=0.92) and differed on average by 0.09 log, with 95.3% of the samples being within the 95% limit of agreement of the assays. Linearity for viral loads 1-7 log was excellent for both assays (R2>0.98). The two assays had similar bias and precision across the different genotypes tested at low viral loads (25-1000 IU/mL). Aptima has a performance comparable with that of HPS/CTM, making it suitable for use for HBV infection monitoring. Aptima runs on a fully automated platform (the Panther system) and therefore offers a significantly improved workflow compared with HPS/CTM.
NASA Technical Reports Server (NTRS)
Rich, T. R.; Mix, T. W.
1974-01-01
Recovery of potable water from urine on manned space missions of extended duration was the objective of work aimed at the improvement of membrane performance for the vapor diffusion process (VDR). Kynar, Teflon, PVC, and polysulfone candidate membranes were evaluated from chemical, thermal, mechanical, and fabricating standpoints to determine their suitability for operation in the VDR pervaporation module. Pervaporation rates and other performance characteristics were determined in a breadboard pervaporator test rig. Kynar and Teflon membranes were demonstrated to be chemically stable at pervaporation temperatures in urine pretreated with chromic acid bactericide. The separation of the pervaporator and condenser modules, the use of a recirculating sweep gas to conduct pervaporate to the condenser, and the selection of a hollow fiber membrane configuration for pervaporator module design is recommended as a result of the investigation.
Suboptimal Performance in Cleft Lip/Palate Children- Who is Responsible?
Lakhkar, Bhavana B
2016-10-01
Information in this article is from an observational study comparing intelligence in children with cleft lip and palate with normal children. Both groups performed "draw a man test", the investigator noted the attitude and behaviour of children and their parents. The study shows low, but normal intelligence quotient in children with oral defects as compared to normal. The probable reason for sub-normal performance appeared to be overprotective attitude of parents and poor self esteem of children with oral defects.
The control of manual entry accuracy in management/engineering information systems, phase 1
NASA Technical Reports Server (NTRS)
Hays, Daniel; Nocke, Henry; Wilson, Harold; Woo, John, Jr.; Woo, June
1987-01-01
It was shown that clerical personnel can be tested for proofreading performance under simulated industrial conditions. A statistical study showed that errors in proofreading follow an extreme value probability theory. The study showed that innovative man/machine interfaces can be developed to improve and control accuracy during data entry.
Evolutionary space platform concept study. Volume 2, part B: Manned space platform concepts
NASA Technical Reports Server (NTRS)
1982-01-01
Logical, cost-effective steps in the evolution of manned space platforms are investigated and assessed. Tasks included the analysis of requirements for a manned space platform, identifying alternative concepts, performing system analysis and definition of the concepts, comparing the concepts and performing programmatic analysis for a reference concept.
Design, fabrication and test of a 4750 Newton-meter-second double Gimbal control moment gyroscope
NASA Technical Reports Server (NTRS)
Cook, Lewis; Golley, Paul; Krome, Henning; Blondin, Joseph; Gurrisi, Charles; Kolvek, John
1989-01-01
The development of a prototype Control Moment Gyroscope (CMG) is discussed. Physical characteristics and the results of functional testing are presented to demonstrate the level of system performance obtained. Particular attention is given to how the man-rated mission requirement influenced the choice of the materials, fabrication, and design details employed. Comparisons are made of the measured system responses against the prediction generated by computer simulation.
The needs of aphasic patients for verbal communication as the element of life quality.
Kulik, Teresa Bernadetta; Koc-Kozłowiec, Barbara; Wrońska, Irena; Rudnicka-Drozak, Ewa
2003-01-01
The fact of using the language by man confirms the specific properties of his brain. Man is not able to learn this skill without a contact with speaking and human environment. This skill of linguistic communication with others allows man to get knowledge about the surrounding world and on the other hand it enables him to express his thoughts, feelings and needs. Therefore, people with serious speech disorders, i.e. aphasic patients, suffer not only from the problems connected with communication but mainly because of the deterioration of their social status that consequently will change their life quality. Generally, they cannot cope with the tasks they are lacking both in their personal and professional life. Speech is defined as the process of communication; the act in which the transmitter sends verbal structured message (statement), and the receiver perceives this message or understands its contents. The present paper presents the realised programme of 8-week speech re-education of 10 patients with motor aphasia and 10 patients with sensory aphasia. The examination of speech was performed on the basis of clinical-experimental tests developed by A. Luria. Diagnostic treatment in this test is focused on the qualitative analysis of the disorders structure.
Flight control system design factors for applying automated testing techniques
NASA Technical Reports Server (NTRS)
Sitz, Joel R.; Vernon, Todd H.
1990-01-01
Automated validation of flight-critical embedded systems is being done at ARC Dryden Flight Research Facility. The automated testing techniques are being used to perform closed-loop validation of man-rated flight control systems. The principal design features and operational experiences of the X-29 forward-swept-wing aircraft and F-18 High Alpha Research Vehicle (HARV) automated test systems are discussed. Operationally applying automated testing techniques has accentuated flight control system features that either help or hinder the application of these techniques. The paper also discusses flight control system features which foster the use of automated testing techniques.
NASA Technical Reports Server (NTRS)
1977-01-01
Captive-active tests consisted of three mated carrier aircraft/Orbiter flights with an active manned Orbiter. The objectives of this series of flights were to (1) verify the separation profile, (2) verify the integrated structure, aerodynamics, and flight control system, (3) verify Orbiter integrated system operations, and (4) refine and finalize carrier aircraft, Orbiter crew, and ground procedures in preparation for free flight tests. A summary description of the flights is presented with assessments of flight test requirements, and of the performance operations, and of significant flight anomalies is included.
42 CFR 84.99 - Man tests; testing conditions; general requirements.
Code of Federal Regulations, 2010 CFR
2010-10-01
... 42 Public Health 1 2010-10-01 2010-10-01 false Man tests; testing conditions; general requirements. 84.99 Section 84.99 Public Health PUBLIC HEALTH SERVICE, DEPARTMENT OF HEALTH AND HUMAN SERVICES OCCUPATIONAL SAFETY AND HEALTH RESEARCH AND RELATED ACTIVITIES APPROVAL OF RESPIRATORY PROTECTIVE DEVICES Self-Contained Breathing Apparatus § 84.99...
Heuvelink, Annet; Hassan, Abdulwahed Ahmed; van Weering, Hilmar; van Engelen, Erik; Bülte, Michael; Akineden, Ömer
2017-05-01
Mycobacterium avium subsp. paratuberculosis (MAP) is a vigorous microorganism which causes incurable chronic enteritis, Johne's disease (JD) in cattle. A target of control programmes for JD is to accurately detect MAP-infected cattle early to reduce disease transmission. The present study evaluated the efficacy of two different cultural procedures and a TaqMan real-time PCR assay for detection of subclinical paratuberculosis in dairy herds. Therefore, sixty-one faecal samples were collected from two Dutch dairy herds (n = 40 and n = 21, respectively) which were known to be MAP-ELISA positive. All individual samples were assessed using two different cultural protocols in two different laboratories. The first cultural protocol (first laboratory) included a decontamination step with 0.75% hexadecylpyridinium chloride (HPC) followed by inoculation on Herrold's egg yolk media (HEYM). The second protocol (second laboratory) comprised of a decontamination step using 4% NaOH and malachite green-oxalic acid followed by inoculation on two media, HEYM and in parallel on modified Löwenstein-Jensen media (mLJ). For the TaqMan real-time PCR assay, all faecal samples were tested in two different laboratories using TaqMan® MAP (Johne's) reagents (Life Technologies). The cultural procedures revealed positive reactions in 1.64% of the samples for cultivation protocol 1 and 6.56 and 8.20% of the samples for cultivation protocol 2, respectively. The results of the TaqMan real-time PCR performed in two different laboratories yielded 13.11 and 19.76% positive reaction. The kappa test showed proportional agreement 0.54 between the mLJ media (second laboratory) and TaqMan® real-time PCR method (second laboratory). In conclusion, the TaqMan real-time PCR could be a strongly useful and efficient assay for the detection of subclinical paratuberculosis in dairy cattle leading to an improvement in the efficiency of MAP control strategies.
Space: exploration-exploitation and the role of man.
Loftus, J P
1986-10-01
The early years of space activity have emphasized a crew role similar to that of the test pilot or the crew of a high performance aircraft; even the Apollo lunar exploration missions were dominated by the task of getting to and from the moon. Skylab was a prototype space station and began to indicate the range of other functional roles man will play in space. The operation of the Space Shuttle has the elements of the operation of any other high performance flight vehicle during launch and landing; but in its on-orbit operations, it is often a surrogate space station, developing techniques and demonstrating the role of a future space station in various functions. In future space systems, the role of the crew will encompass all of the activities pursued in research laboratories, manufacturing facilities, maintenance shops, and construction sites. The challenge will be to design the tasks and the tools so that the full benefit of the opportunities offered by performing these functions in space can be attained.
Skylab experiment M-171 'Metabolic Activity' - Results of the first manned mission
NASA Technical Reports Server (NTRS)
Michel, E. L.; Rummel, J. A.; Sawin, C. F.
1975-01-01
The experiment was performed to ascertain whether man's ability to perform mechanical work would be altered as a result of exposure to the weightless environment. Skylab II crewmen were exercised on a bicycle ergometer at loads approximating 25%, 50%, and 75% of their maximum oxygen uptake while their physiological responses were monitored. The results of these tests indicate that the crewmen had no significant decrement in their response to exercise during their exposure to zero gravity. Immediately postflight, however, all crewmen demonstrated an inability to perform the programmed exercise with the same metabolic effectiveness as they did both preflight and inflight. The most significant changes were elevated heart rates for the same work load and oxygen consumption (decreased oxygen pulse), decreased stroke volume, and decreased cardiac output at the same oxygen consumption level. It is apparent that the changes occurred inflight, but did not manifest themselves until the crewmen attempted to readapt to the 1-G environment.
Lee, Kyung Jin; Kim, Jaeyeon; Shin, Dong Hwan; Jung, Jun Oh; Koh, Seokyoung; Kim, Ka Young; Lee, Jae Min
2015-12-01
We report the case of a 20-year-old man with a 2-month history of anal pain and bloody rectal discharge. He was referred to our clinic of gastroenterology for suspected inflammatory bowel disease (IBD). The colonoscopy showed mucosal nodularities on the rectum and an anal tag. Because the colonoscopic findings were not consistent with the typical manifestations of IBD, we took an additional sexual history and performed studies for infectious proctitis, including serologic tests for Chlamydia trachomatis, Neisseria gonorrhoeae, and Treponema pallidum. He had homosexual experience, and the serologic tests and PCR of a rectal swab were positive for C. trachomatis infection. Finally he was diagnosed as having chlamydial proctitis and was treated with intramuscular ceftriaxone 250 mg in a single dose and doxycycline 100 mg orally twice daily for 7 days. After 2 months, he had no lower abdominal symptoms and his endoscopic findings were improved.
Repeat testing of low-level HIV-1 RNA: assay performance and implementation in clinical trials.
White, Kirsten; Garner, Will; Wei, Lilian; Eron, Joseph J; Zhong, Lijie; Miller, Michael D; Martin, Hal; Plummer, Andrew; Tran-Muchowski, Cecilia; Lindstrom, Kim; Porter, James; Piontkowsky, David; Light, Angela; Reiske, Heinz; Quirk, Erin
2018-05-15
Assess the performance of HIV-1 RNA repeat testing of stored samples in cases of low-level viremia during clinical trials. Prospective and retrospective analysis of randomized clinical trial samples and reference standards. To evaluate assay variability of the Cobas AmpliPrep/Cobas TaqMan HIV-1 Test, v2.0, three separate sources of samples were utilized: the World Health Organization (WHO) HIV reference standard (assayed using 50 independent measurements at six viral loads <200 copies/ml), retrospective analysis of four to six aliquots of plasma samples from four clinical trial participants, and prospective repeat testing of 120 samples from participants in randomized trials with low-level viremia. The TaqMan assay on the WHO HIV-1 RNA standards at viral loads <200 copies/ml performed within the expected variability according to assay specifications. However, standards with low viral loads of 36 and 18 copies/ml reported values of ≥ 50 copies/ml in 66 and 18% of tests, respectively. In participants treated with antiretrovirals who had unexpected viremia of 50-200 copies/ml after achieving <50 copies/ml, retesting of multiple aliquots of stored plasma found <50 copies/ml in nearly all cases upon retesting (14/15; 93%). Repeat testing was prospectively implemented in four clinical trials for all samples with virologic rebound of 50-200 copies/ml (n = 120 samples from 92 participants) from which 42% (50/120) had a retest result of less than 50 copies/ml and 58% (70/120) retested ≥ 50 copies/ml. The TaqMan HIV-1 RNA assay shows variability around 50 copies/ml that affects clinical trial results and may impact clinical practice. In participants with a history of viral load suppression, unexpected low-level viremia may be because of assay variability rather than low drug adherence or true virologic failure. Retesting a stored aliquot of the same sample may differentiate between assay variability and virologic failure as the source of viremia. This retesting strategy could save time, money, and anxiety for patients and their providers, as well as decrease follow-up clinic visits without increasing the risk of virologic failure and resistance development.
The Orion Atmosphere Revitalization Technology in Manned Ambient Pressure Space Suit Testing
NASA Technical Reports Server (NTRS)
Button, Amy; Sweterlitsch, Jeffrey
2011-01-01
An amine-based carbon dioxide (CO2) and water vapor sorbent in pressure-swing regenerable beds has been developed by Hamilton Sundstrand and baselined for the Atmosphere Revitalization System (ARS) for moderate duration missions of the Orion Multipurpose Crew Vehicle. The Orion ARS is designed to support not only open-cabin operations, tests of which have been reported in previous years at this conference, but also closed space suit-loop operations. A previous low-pressure suit loop test was performed with a human metabolic simulator, and humans wearing emergency masks were tested in a closed-loop configuration before that. In late 2011, simple tests were performed in a suit-loop configuration with human test subjects in prototype space suits with prototype umbilicals at ambient and two slightly above-ambient pressures. Trace contaminant filters and a prototype blower were also incorporated into the test rig. This paper discusses the performance of the ARS technology in that 2011 test configuration.
NASA Technical Reports Server (NTRS)
1971-01-01
A preliminary plan and procedure are presented for conducting an extended manned test program for a regenerative life support system. Emphasis will be placed on elements associated with long-term system operation and long-term uninterrupted crew confinement.
29 CFR 780.305 - 500 man-day provision.
Code of Federal Regulations, 2011 CFR
2011-07-01
... 29 Labor 3 2011-07-01 2011-07-01 false 500 man-day provision. 780.305 Section 780.305 Labor...) Statutory Provisions § 780.305 500 man-day provision. (a) Section 3(u) of the Act defines man-day to mean “any day during which an employee performs agricultural labor for not less than 1 hour.” 500 man-days...
29 CFR 780.305 - 500 man-day provision.
Code of Federal Regulations, 2013 CFR
2013-07-01
... 29 Labor 3 2013-07-01 2013-07-01 false 500 man-day provision. 780.305 Section 780.305 Labor...) Statutory Provisions § 780.305 500 man-day provision. (a) Section 3(u) of the Act defines man-day to mean “any day during which an employee performs agricultural labor for not less than 1 hour.” 500 man-days...
29 CFR 780.305 - 500 man-day provision.
Code of Federal Regulations, 2012 CFR
2012-07-01
... 29 Labor 3 2012-07-01 2012-07-01 false 500 man-day provision. 780.305 Section 780.305 Labor...) Statutory Provisions § 780.305 500 man-day provision. (a) Section 3(u) of the Act defines man-day to mean “any day during which an employee performs agricultural labor for not less than 1 hour.” 500 man-days...
29 CFR 780.305 - 500 man-day provision.
Code of Federal Regulations, 2014 CFR
2014-07-01
... 29 Labor 3 2014-07-01 2014-07-01 false 500 man-day provision. 780.305 Section 780.305 Labor...) Statutory Provisions § 780.305 500 man-day provision. (a) Section 3(u) of the Act defines man-day to mean “any day during which an employee performs agricultural labor for not less than 1 hour.” 500 man-days...
Research on regulating technique of material flow for 2-person and 30-day integrated CELSS test
NASA Astrophysics Data System (ADS)
Guo, Shuangsheng; Dong, Wenping; Ai, Weidang; Feng, Hongqi; Tang, Yongkang; Huang, Zhide; Shen, Yunze; Ren, Jin; Qin, Lifeng; Zeng, Gu; Zhang, Lihong; Zhu, Jingtao; Fei, Jinxue; Xu, Guoxin
2014-07-01
A man-plant integration test was processed using the CELSS integration experiment platform in which 4 kinds of plants were grown (Lactuca sativa L var. Dasusheng, L. sativa L var. Youmaicai, Gynura bicolor and Cichorium endivia L) to exchange material with 2 persons in order to research the dynamic changing laws and balanced regulation of air and water between man and plant in an inclosed system. In the test the material flow was measured so that the dynamically changing laws and balanced regulation of air and water between man and plant in the closed system were mostly mastered. The material closure degree of air, water and food reached 100%, 90% and 13.9% respectively with the whole system closure degree up to 95.1%. Meanwhile, it was proved that a 13.5 m2 planting area could meet the demand of one person for O2 in the system, and the energy efficiency ratio of which reached 59.56 g/(kW m2 day). The material flow dynamic balance-regulating technology was initially mastered between man and plant through the test. The interaction was realized among man, plant and environment in the closed system, which is of great significance to the advancement of long-term manned environment control and life support technology for China.
History of suborbital spaceflight: medical and performance issues.
Campbell, Mark R; Garbino, Alejandro
2011-04-01
The development of manned sub-orbital commercial space vehicles is rapidly occurring and flight testing followed by operational flights will soon begin. The experience of manned suborbital spaceflight at the designated altitude (100 km/62.14 mi) is very limited--two Mercury-Redstone flights, two X-15 flights, one inadvertent Soyuz launch abort, and three recent SpaceShipOne flights, with only 15 min of critical flight time each. All indications were that the sequence of acceleration-weightlessness-deceleration was well tolerated with minimal neurovestibular dysfunction. However, there are some indications that distraction and spatial disorientation did occur. Vertigo on transition from the boost phase to weightlessness was reported on most high-altitude X-15 flights. +Gz tolerance to re-entry deceleration forces (as high as 6 + Gz) after 4 min of weightlessness is still unknown. Only further suborbital spaceflight experience will clarify if pilot performance will be affected.
Zarei, Eghbal; Sanaeimanesh, Mehri
2014-01-01
This study aimed to examine the effect of self-disclosure skill training on communication patterns of referred couples to counseling clinics in Bandar Abbas. The applied research design was an experimental study using pre-test and post-test, which was performed on a population of all referred couples to counseling clinics in Bandar Abbas who were interested to participate in a self-disclosure training workshop in response to the announcement. This study was performed on 26 couples who were selected by simple, convenient sampling method; however, they were randomly assigned to the control and experiment groups. A pre-test was administrated before self-disclosure training. The applied instrument includes Christensen and Salavy's scale of communication patterns. Participants in the experiment group had six sessions of training workshop, each lasted for 90 min. After the intervention, both groups answered the questionnaire again. The collected data were analyzed with paired t-test and covariance statistics. The results showed that the intervention led to significant (p < 0.05) increase in mutual constructive communication pattern and a reduction in mutual avoidance, demand/withdraw, demanding man/withdrawing woman communication patterns. It was also found that the training was not effective on the communication pattern of demanding woman/withdrawing man. The training of simple, but important skills of self-disclosure can help couples to improve their communication and consequently improve their marital satisfaction.
Design and fabrication of a four-man capacity urine wick evaporator system
NASA Technical Reports Server (NTRS)
1979-01-01
The integrated system was tested to determine the performance characteristics and limitations of the dual catalyst concept. The primary objective of the dual catalyst concept is to remove ammonia and other noxious substances in the gas phase and thereby eliminate the need for and current practice of chemically or electrochemically pretreating urine prior to distillation.
Results of the Second U.S. Manned Suborbital Space Flight, July 21, 1961
NASA Technical Reports Server (NTRS)
1961-01-01
This document presents the results of the second United States manned suborbital space flight. The data and flight description presented form a continuation of the information provided at an open conference held under the auspices of the National Aeronautics and Space Administration, in cooperation with the National Institutes of Health and the National Academy of Sciences, at the U.S. Department of State Auditorium on June 6, 1961. The papers presented herein generally parallel the presentations of the first report and were prepared by the personnel of the NASA Manned Spacecraft Center in collaboration with personnel from other government agencies, participating industry, and universities. The second successful manned suborbital space flight on July 21, 1961, in which Astronaut Virgil I. Grissom was the pilot was another step in the progressive research, development, and training program leading to the study of man's capabilities in a space environment during manned orbital flight. Data and operational experiences gained from this flight were in agreement with and supplemented the knowledge obtained from the first suborbital flight of May 5, 1961, piloted by Astronaut Alan B. Shepard, Jr. The two recent manned suborbital flights, coupled with the unmanned research and development flights, have provided valuable engineering nd scientific data on which the program can progress. The successful active participation of the pilots, in much the same way as in the development and testing of high performance aircraft, has. greatly increased our confidence in giving man a significant role in future space flight activities. It is the purpose of this report to continue the practice of providing data to the scientific community interested in activities of this nature. Brief descriptions are presented of the Project Mercury spacecraft and flight plan. Papers are provided which parallel the presentations of data published for the first suborbital space flight. Additional information is given relating to the operational aspects of the medical support activities for the two manned suborbital space flights.
Neurovirulence safety testing of mumps vaccines--historical perspective and current status.
Rubin, S A; Afzal, M A
2011-04-05
Many live, attenuated viral vaccines are derived from wild type viruses with known neurovirulent properties. To assure the absence of residual neurotoxicity, pre-clinical neurovirulence safety testing of candidate vaccines is performed. For mumps virus, a highly neurotropic virus, neurovirulence safety testing is performed in monkeys. However, laboratory studies suggest an inability of this test to correctly discern among virus strains of varying neurovirulence potential in man, and, further, some vaccines found to be neuroattenuated in monkeys were later found to be neurovirulent in humans when administered in large numbers. Over the past decade, concerted efforts have been made to replace monkey-based neurovirulence safety testing with more informative, alternative methods. This review summarizes the current status of mumps vaccine neurovirulence safety testing and insights into models currently approved and those under development. Published by Elsevier Ltd.
Apollo Telescope Mount (ATM) gimballed star tracker. [developed for the Skylab program
NASA Technical Reports Server (NTRS)
Lana, J. D.
1974-01-01
Design and development of six gimballed star trackers for Skylab's Apollo Telescope Mount, which performed successfully on all three manned Skylab missions and accumulated a total usage time of approximately 3,500 hours, is described in terms of configurations, materials and construction, qualification testing, performance, and reliability characteristics. A brief program history and design changes incorporated during the life of the program are also discussed. Extensive drawings, block diagrams, and photographs are provided.
Katsoulidou, Antigoni; Petrodaskalaki, Maria; Sypsa, Vana; Papachristou, Eleni; Anastassopoulou, Cleo G; Gargalianos, Panagiotis; Karafoulidou, Anastasia; Lazanas, Marios; Kordossis, Theodoros; Andoniadou, Anastasia; Hatzakis, Angelos
2006-02-01
The COBAS TaqMan HIV-1 test (Roche Diagnostics) was compared with the LCx HIV RNA quantitative assay (Abbott Laboratories), the Versant HIV-1 RNA 3.0 (bDNA) assay (Bayer) and the COBAS Amplicor HIV-1 Monitor v1.5 test (Roche Diagnostics), using plasma samples of various viral load levels from HIV-1-infected individuals. In the comparison of TaqMan with LCx, TaqMan identified as positive 77.5% of the 240 samples versus 72.1% identified by LCx assay, while their overall agreement was 94.6% and the quantitative results of samples that were positive by both methods were strongly correlated (r=0.91). Similarly, in the comparison of TaqMan with bDNA 3.0, both methods identified 76.3% of the 177 samples as positive, while their overall agreement was 95.5% and the quantitative results of samples that were positive by both methods were strongly correlated (r=0.95). Finally, in the comparison of TaqMan with Monitor v1.5, TaqMan identified 79.5% of the 156 samples as positive versus 80.1% identified by Monitor v1.5, while their overall agreement was 95.5% and the quantitative results of samples that were positive by both methods were strongly correlated (r=0.96). In conclusion, the new COBAS TaqMan HIV-1 test showed excellent agreement with other widely used commercially available tests for the quantitation of HIV-1 viral load.
Adani, Flavia; Stegenwallner-Schütz, Maja; Niesel, Talea
2017-01-01
The predictions of two contrasting approaches to the acquisition of transitive relative clauses were tested within the same groups of German-speaking participants aged from 3 to 5 years old. The input frequency approach predicts that object relative clauses with inanimate heads (e.g., the pullover that the man is scratching) are comprehended earlier and more accurately than those with an animate head (e.g., the man that the boy is scratching). In contrast, the structural intervention approach predicts that object relative clauses with two full NP arguments mismatching in number (e.g., the man that the boys are scratching) are comprehended earlier and more accurately than those with number-matching NPs (e.g., the man that the boy is scratching). These approaches were tested in two steps. First, we ran a corpus analysis to ensure that object relative clauses with number-mismatching NPs are not more frequent than object relative clauses with number-matching NPs in child directed speech. Next, the comprehension of these structures was tested experimentally in 3-, 4-, and 5-year-olds respectively by means of a color naming task. By comparing the predictions of the two approaches within the same participant groups, we were able to uncover that the effects predicted by the input frequency and by the structural intervention approaches co-exist and that they both influence the performance of children on transitive relative clauses, but in a manner that is modulated by age. These results reveal a sensitivity to animacy mismatch already being demonstrated by 3-year-olds and show that animacy is initially deployed more reliably than number to interpret relative clauses correctly. In all age groups, the animacy mismatch appears to explain the performance of children, thus, showing that the comprehension of frequent object relative clauses is enhanced compared to the other conditions. Starting with 4-year-olds but especially in 5-year-olds, the number mismatch supported comprehension—a facilitation that is unlikely to be driven by input frequency. Once children fine-tune their sensitivity to verb agreement information around the age of four, they are also able to deploy number marking to overcome the intervention effects. This study highlights the importance of testing experimentally contrasting theoretical approaches in order to characterize the multifaceted, developmental nature of language acquisition. PMID:29033863
Orion Launch Abort System Jettison Motor Performance During Exploration Flight Test 1
NASA Technical Reports Server (NTRS)
McCauley, Rachel J.; Davidson, John B.; Winski, Richard G.
2015-01-01
This paper presents an overview of the flight test objectives and performance of the Orion Launch Abort System during Exploration Flight Test-1. Exploration Flight Test-1, the first flight test of the Orion spacecraft, was managed and led by the Orion prime contractor, Lockheed Martin, and launched atop a United Launch Alliance Delta IV Heavy rocket. This flight test was a two-orbit, high-apogee, high-energy entry, low-inclination test mission used to validate and test systems critical to crew safety. This test included the first flight test of the Launch Abort System performing Orion nominal flight mission critical objectives. Although the Orion Program has tested a number of the critical systems of the Orion spacecraft on the ground, the launch environment cannot be replicated completely on Earth. Data from this flight will be used to verify the function of the jettison motor to separate the Launch Abort System from the crew module so it can continue on with the mission. Selected Launch Abort System flight test data is presented and discussed in the paper. Through flight test data, Launch Abort System performance trends have been derived that will prove valuable to future flights as well as the manned space program.
Kim, Hyerin; Kang, NaNa; An, KyuHyeon; Koo, JaeHyung; Kim, Min-Soo
2016-07-08
Design of high-quality primers for multiple target sequences is essential for qPCR experiments, but is challenging due to the need to consider both homology tests on off-target sequences and the same stringent filtering constraints on the primers. Existing web servers for primer design have major drawbacks, including requiring the use of BLAST-like tools for homology tests, lack of support for ranking of primers, TaqMan probes and simultaneous design of primers against multiple targets. Due to the large-scale computational overhead, the few web servers supporting homology tests use heuristic approaches or perform homology tests within a limited scope. Here, we describe the MRPrimerW, which performs complete homology testing, supports batch design of primers for multi-target qPCR experiments, supports design of TaqMan probes and ranks the resulting primers to return the top-1 best primers to the user. To ensure high accuracy, we adopted the core algorithm of a previously reported MapReduce-based method, MRPrimer, but completely redesigned it to allow users to receive query results quickly in a web interface, without requiring a MapReduce cluster or a long computation. MRPrimerW provides primer design services and a complete set of 341 963 135 in silico validated primers covering 99% of human and mouse genes. Free access: http://MRPrimerW.com. © The Author(s) 2016. Published by Oxford University Press on behalf of Nucleic Acids Research.
NASA Technical Reports Server (NTRS)
Jackola, Arthur S.; Hartjen, Gary L.
1992-01-01
The plans for a new test facility, including new environmental test systems, which are presently under construction, and the major environmental Test Support Equipment (TSE) used therein are addressed. This all-new Rocketdyne facility will perform space simulation environmental tests on Power Management and Distribution (PMAD) hardware to Space Station Freedom (SSF) at the Engineering Model, Qualification Model, and Flight Model levels of fidelity. Testing will include Random Vibration in three axes - Thermal Vacuum, Thermal Cycling and Thermal Burn-in - as well as numerous electrical functional tests. The facility is designed to support a relatively high throughput of hardware under test, while maintaining the high standards required for a man-rated space program.
Develop Advanced Nonlinear Signal Analysis Topographical Mapping System
NASA Technical Reports Server (NTRS)
Jong, Jen-Yi
1997-01-01
During the development of the SSME, a hierarchy of advanced signal analysis techniques for mechanical signature analysis has been developed by NASA and AI Signal Research Inc. (ASRI) to improve the safety and reliability for Space Shuttle operations. These techniques can process and identify intelligent information hidden in a measured signal which is often unidentifiable using conventional signal analysis methods. Currently, due to the highly interactive processing requirements and the volume of dynamic data involved, detailed diagnostic analysis is being performed manually which requires immense man-hours with extensive human interface. To overcome this manual process, NASA implemented this program to develop an Advanced nonlinear signal Analysis Topographical Mapping System (ATMS) to provide automatic/unsupervised engine diagnostic capabilities. The ATMS will utilize a rule-based Clips expert system to supervise a hierarchy of diagnostic signature analysis techniques in the Advanced Signal Analysis Library (ASAL). ASAL will perform automatic signal processing, archiving, and anomaly detection/identification tasks in order to provide an intelligent and fully automated engine diagnostic capability. The ATMS has been successfully developed under this contract. In summary, the program objectives to design, develop, test and conduct performance evaluation for an automated engine diagnostic system have been successfully achieved. Software implementation of the entire ATMS system on MSFC's OISPS computer has been completed. The significance of the ATMS developed under this program is attributed to the fully automated coherence analysis capability for anomaly detection and identification which can greatly enhance the power and reliability of engine diagnostic evaluation. The results have demonstrated that ATMS can significantly save time and man-hours in performing engine test/flight data analysis and performance evaluation of large volumes of dynamic test data.
Results of Skylab medical experiment M171: Metabolic activity
NASA Technical Reports Server (NTRS)
Michel, E. L.; Rummel, J. A.; Sawin, C. F.; Buderer, M. C.; Lem, J. D.
1974-01-01
The experiment was conducted to establish whether man's ability to perform mechanical work would be progressively altered as a result of exposure to the weightless environment of space flight. The Skylab crewmen exercised on a bicycle ergometer at workloads approximating 25, 50, and 75 percent of their maximum aerobic capacity. The physiological parameters monitored were respiratory gas exchange, blood pressure, and vectorcardiogram/heart rate. The results of these tests indicate that the crewmen had no significant decrement in their responses to exercise during their exposure to zero gravity. The results of the third manned Skylab mission (Skylab 4) are presented and a comparison is made of the overall results obtained from the three successively longer Skylab manned missions. The Skylab 4 crewmembers' 84-day in-flight responses to exercise were no worse and were probably better than the responses of the crewmen on the first two Skylab missions. Indications that exercise was an important contributing factor in maintaining this response are discussed.
Electronics systems test laboratory testing of shuttle communications systems
NASA Technical Reports Server (NTRS)
Stoker, C. J.; Bromley, L. K.
1985-01-01
Shuttle communications and tracking systems space to space and space to ground compatibility and performance evaluations are conducted in the NASA Johnson Space Center Electronics Systems Test Laboratory (ESTL). This evaluation is accomplished through systems verification/certification tests using orbiter communications hardware in conjunction with other shuttle communications and tracking external elements to evaluate end to end system compatibility and to verify/certify that overall system performance meets program requirements before manned flight usage. In this role, the ESTL serves as a multielement major ground test facility. The ESTL capability and program concept are discussed. The system test philosophy for the complex communications channels is described in terms of the major phases. Results of space to space and space to ground systems tests are presented. Several examples of the ESTL's unique capabilities to locate and help resolve potential problems are discussed in detail.
Apollo experience report: Electronic systems test program accomplishments and results
NASA Technical Reports Server (NTRS)
Ohnesorge, T. E.
1972-01-01
A chronological record is presented of the Electronic Systems Test Program from its conception in May 1963 to December 1969. The original concept of the program, which was primarily a spacecraft/Manned Space Flight Network communications system compatibility and performance evaluation, is described. The evolution of these concepts to include various levels of test detail, as well as systems level design verification testing, is discussed. Actual implementation of these concepts is presented, and the facility to support the program is described. Test results are given, and significant contributions to the lunar landing mission are underlined. Plans for modifying the facility and the concepts, based on Apollo experience, are proposed.
Humphries, R M; Hindler, J A
2016-07-01
Accurate and timely performance of antimicrobial susceptibility testing (AST) by the clinical laboratory is paramount to combating antimicrobial resistance. The ability of laboratories in the United States to effectively perform ASTs is challenged by several factors. Some, such as new resistance mechanisms and the associated evolution of testing recommendations and breakpoints, are inevitable. Others are entirely man-made. These include unnecessarily strict US Food and Drug Administration (FDA) limitations on how commercial AST systems can be used for diagnostic testing, the absence of up-to-date performance data on these systems, and the lack of commercially available FDA-cleared tests for newer antimicrobial agents or for older agents with updated breakpoints. This viewpoint will highlight contemporary AST challenges faced by the clinical laboratory, and propose some solutions. © The Author 2016. Published by Oxford University Press for the Infectious Diseases Society of America. All rights reserved. For permissions, e-mail journals.permissions@oup.com.
NASA Technical Reports Server (NTRS)
Anderson, James E.; Tepper, Edward H.; Trevino, Louis A.
1991-01-01
Manned tests in Chamber B at NASA JSC were conducted in May and June of 1990 to better quantify the Space Shuttle Extravehicular Mobility Unit's (EMU) thermal performance in the cold environmental extremes of space. Use of an infrared imaging camera with real-time video monitoring of the output significantly added to the scope, quality and interpretation of the test conduct and data acquisition. Results of this test program have been effective in the thermal certification of a new insulation configuration and the '5000 Series' glove. In addition, the acceptable thermal performance of flight garments with visually deteriorated insulation was successfully demonstrated, thereby saving significant inspection and garment replacement cost. This test program also established a new method for collecting data vital to improving crew thermal comfort in a cold environment.
2009-02-01
antagonist (Nehilg, Daval, & Debry, 1992). It is found naturally in some foods and beverages such as coffee and tea. Caffeine is also common in soft 2...exceeding 600mg, or any history of a sleep disorder. Volunteers were neither allowed to consume caffeine 7 during the test week nor take any...H., Balkin, T., Wesensten, N., and Redmond, D. 1994. The effects of sleep deprivation on performance during continuous combat operations. In Food
Shallow Habitat Air Dive Series (SHAD I and II): The Effects on Visual Performance and Physiology
1974-10-02
APPLICATION Since the tests employed cover all the major, known visual symptoms of oxygen toxicity , the data indicate that man can live under...included a number of measures of visual physiology and visual performance, since many of the symptoms of oxygen toxicity involve the visual system. The...oxygen toxic - ity. Nitrogen narcosis, which normally occurs at 200 to 300 ft, is the lesser of the two problems for shaUow habitat divers, since
ERIC Educational Resources Information Center
Simner, Marvin L.
1985-01-01
An abbreviated scoring system for the Goodenough-Harris Draw-A-Man Test found that three items had the same overall potential for correctly identifying at-risk kindergarteners as more time-consuming scoring methods. (CL)
Man and His Environment: To Perceive and to React: Language Arts. 5111.13.
ERIC Educational Resources Information Center
Bermudez, Lynne L.
A course which is an investigation and appraisal of prose, poetry, fine arts, and music which reflects the environment's effect on man or man's effect on his environment is presented. Performance objectives include the following: (1) Students will formulate a definition of what constitutes man's environment; (2) Students will examine the reactions…
42 CFR 84.161 - Man test for gases and vapors; Type B and Type BE respirators; test requirements.
Code of Federal Regulations, 2010 CFR
2010-10-01
... 42 Public Health 1 2010-10-01 2010-10-01 false Man test for gases and vapors; Type B and Type BE respirators; test requirements. 84.161 Section 84.161 Public Health PUBLIC HEALTH SERVICE, DEPARTMENT OF HEALTH AND HUMAN SERVICES OCCUPATIONAL SAFETY AND HEALTH RESEARCH AND RELATED ACTIVITIES APPROVAL OF RESPIRATORY PROTECTIVE DEVICES Supplied-Air...
42 CFR 84.160 - Man test for gases and vapors; Type A and Type AE respirators; test requirements.
Code of Federal Regulations, 2010 CFR
2010-10-01
... 42 Public Health 1 2010-10-01 2010-10-01 false Man test for gases and vapors; Type A and Type AE respirators; test requirements. 84.160 Section 84.160 Public Health PUBLIC HEALTH SERVICE, DEPARTMENT OF HEALTH AND HUMAN SERVICES OCCUPATIONAL SAFETY AND HEALTH RESEARCH AND RELATED ACTIVITIES APPROVAL OF RESPIRATORY PROTECTIVE DEVICES Supplied-Air...
DOE Office of Scientific and Technical Information (OSTI.GOV)
Protat, A; Young, S
The objective of this field campaign was to evaluate the performance of the new Leosphere R-MAN 510 lidar, procured by the Australian Bureau of Meteorology, by testing it against the MicroPulse Lidar (MPL) and Raman lidars, at the Darwin Atmospheric Radiation Measurement (ARM) site. This lidar is an eye-safe (355 nm), turn-key mini Raman lidar, which allows for the detection of aerosols and cloud properties, and the retrieval of particulate extinction profiles. To accomplish this evaluation, the R-MAN 510 lidar has been operated at the Darwin ARM site, next to the MPL, Raman lidar, and Vaisala ceilometer (VCEIL) for threemore » months (from 20 January 2013 to 20 April 2013) in order to collect a sufficient sample size for statistical comparisons.« less
Lyon, W. J.
2001-01-01
Vibrio cholerae is recognized as a leading human waterborne pathogen. Traditional diagnostic testing for Vibrio is not always reliable, because this bacterium can enter a viable but nonculturable state. Therefore, nucleic acid-based tests have emerged as a useful alternative to traditional enrichment testing. In this article, a TaqMan PCR assay is presented for quantitative detection of V. cholerae in pure cultures, oysters, and synthetic seawater. Primers and probe were designed from the nonclassical hemolysin (hlyA) sequence of V. cholerae strains. This probe was applied to DNA from 60 bacterial strains comprising 21 genera. The TaqMan PCR assay was positive for all of the strains of V. cholerae tested and negative for all other species of Vibrio tested. In addition, none of the other genera tested was amplified with the TaqMan primers and probe used in this study. The results of the TaqMan PCR with raw oysters and spiked with V. cholerae serotypes O1 and O139 were comparable to those of pure cultures. The sensitivity of the assay was in the range of 6 to 8 CFU g−1 and 10 CFU ml−1 in spiked raw oyster and synthetic seawater samples, respectively. The total assay could be completed in 3 h. Quantification of the Vibrio cells was linear over at least 6 log units. The TaqMan probe and primer set developed in this study can be used as a rapid screening tool for the presence of V. cholerae in oysters and seawater without prior isolation and characterization of the bacteria by traditional microbiological methods. PMID:11571173
A new one-man submarine is tested as vehicle for solid rocket booster retrieval
NASA Technical Reports Server (NTRS)
2000-01-01
A mockup of a solid rocket booster nozzle is lowered into the waters of the Atlantic during a test of a new booster retrieval method. A one-man submarine known as DeepWorker 2000 is being tested on its ability to duplicate the sometimes hazardous job United Space Alliance (USA) divers perform to recover the expended boosters in the ocean after a launch. The boosters splash down in an impact area about 140 miles east of Jacksonville and after recovery are towed back to KSC for refurbishment by the specially rigged recovery ships. DeepWorker 2000 will be used in a demonstration during retrieval operations after the upcoming STS-101 launch. The submarine pilot will demonstrate capabilities to cut tangled parachute riser lines using a manipulator arm and attach a Diver Operator Plug to extract water and provide flotation for the booster. DeepWorker 2000 was built by Nuytco Research Ltd., North Vancouver, British Columbia. It is 8.25 feet long, 5.75 feet high, and weighs 3,800 pounds. USA is a prime contractor to NASA for the Space Shuttle program.
A new one-man submarine is tested as vehicle for solid rocket booster retrieval
NASA Technical Reports Server (NTRS)
2000-01-01
- The one-man submarine known as DeepWorker 2000 is tested in Atlantic waters near Cape Canaveral, Fla. Nearby are divers; inside the sub is the pilot, Anker Rasmussen. The sub is being tested on its ability to duplicate the sometimes hazardous job United Space Alliance (USA) divers perform to recover the expended boosters in the ocean after a launch. The boosters splash down in an impact area about 140 miles east of Jacksonville and after recovery are towed back to KSC for refurbishment by the specially rigged recovery ships. DeepWorker 2000 will be used in a demonstration during retrieval operations after the upcoming STS-101 launch. The submarine pilot will demonstrate capabilities to cut tangled parachute riser lines using a manipulator arm and attach a Diver Operator Plug to extract water and provide flotation for the booster. DeepWorker 2000 was built by Nuytco Research Ltd., North Vancouver, British Columbia. It is 8.25 feet long, 5.75 feet high, and weighs 3,800 pounds. USA is a prime contractor to NASA for the Space Shuttle program.
NASA Astrophysics Data System (ADS)
Yim, S.-W.; Yu, S.-D.; Kim, H.-R.; Kim, M.-J.; Park, C.-R.; Yang, S.-E.; Kim, W.-S.; Hyun, O.-B.; Sim, J.; Park, K.-B.; Oh, I.-S.
2010-11-01
We have constructed and completed the preparation for a long-term operation test of a superconducting fault current limiter (SFCL) in a Korea Electric Power Corporation (KEPCO) test grid. The SFCL with rating of 22.9 kV/630 A, 3-phases, has been connected to the 22.9 kV test grid equipped with reclosers and other protection devices in Gochang Power Testing Center of KEPCO. The main goals of the test are the verification of SFCL performance and protection coordination studies. A line-commutation type SFCL was fabricated and installed for this project, and the superconducting components were cooled by a cryo-cooler to 77 K in the sub-cooled liquid nitrogen pressurized by 3 bar of helium gas. The verification test includes un-manned - long-term operation with and without loads and fault tests. Since the test site is 170 km away from the laboratory, we will adopt the un-manned operation with real-time remote monitoring and controlling using high speed internet. For the fault tests, we will apply fault currents up to around 8 kArms to the SFCL using an artificial fault generator. The fault tests may allow us not only to confirm the current limiting capability of the SFCL, but also to adjust the SFCL - recloser coordination such as resetting over-current relay parameters. This paper describes the construction of the testing facilities and discusses the plans for the verification tests.
Re-Design and Beat Testing of the Man-Machine Integration Design and Analysis System: MIDAS
NASA Technical Reports Server (NTRS)
Shively, R. Jay; Rutkowski, Michael (Technical Monitor)
1999-01-01
The Man-machine Design and Analysis System (MIDAS) is a human factors design and analysis system that combines human cognitive models with 3D CAD models and rapid prototyping and simulation techniques. MIDAS allows designers to ask 'what if' types of questions early in concept exploration and development prior to actual hardware development. The system outputs predictions of operator workload, situational awareness and system performance as well as graphical visualization of the cockpit designs interacting with models of the human in a mission scenario. Recently, MIDAS was re-designed to enhance functionality and usability. The goals driving the redesign include more efficient processing, GUI interface, advances in the memory structures, implementation of external vision models and audition. These changes were detailed in an earlier paper. Two Beta test sites with diverse applications have been chosen. One Beta test site is investigating the development of a new airframe and its interaction with the air traffic management system. The second Beta test effort will investigate 3D auditory cueing in conjunction with traditional visual cueing strategies including panel-mounted and heads-up displays. The progress and lessons learned on each of these projects will be discussed.
Preprototype Vapor Compression Distillation Subsystem development
NASA Technical Reports Server (NTRS)
Thompson, C. D.; Ellis, G. S.; Schubert, F. H.
1981-01-01
Vapor Compression Distillation (VCD) has evolved as the most promising approach to reclaim potable water from wastewater for future long-term manned space missions. Life Systems, Inc. (LSI), working with NASA, has developed a preprototype Vapor Compression Distillation Subsystem (VCDS) which processes wastewater at 1.4 kg/h. The preprototype unit weighs 143 kg, occupies a volume of 0.47 cu m, and will reclaim 96 percent of the available wastewater. This unit has been tested by LSI and is scheduled for further testing at NASA-JSC. This paper presents the preprototype VCDS design, configuration, performance data, test results and flight system projections.
Goldstone field test activities: Target search
NASA Technical Reports Server (NTRS)
Tarter, J.
1986-01-01
In March of this year prototype SETI equipment was installed at DSS13, the 26 meter research and development antenna at NASA's Goldstone complex of satellite tracking dishes. The SETI equipment will remain at this site at least through the end of the summer so that the hardware and software developed for signal detection and recognition can be fully tested in a dynamic observatory environment. The field tests are expected to help understand which strategies for observing and which signal recognition algorithms perform best in the presence of strong man-made interfering signals (RFI) and natural astronomical sources.
A Manual Segmentation Tool for Three-Dimensional Neuron Datasets.
Magliaro, Chiara; Callara, Alejandro L; Vanello, Nicola; Ahluwalia, Arti
2017-01-01
To date, automated or semi-automated software and algorithms for segmentation of neurons from three-dimensional imaging datasets have had limited success. The gold standard for neural segmentation is considered to be the manual isolation performed by an expert. To facilitate the manual isolation of complex objects from image stacks, such as neurons in their native arrangement within the brain, a new Manual Segmentation Tool (ManSegTool) has been developed. ManSegTool allows user to load an image stack, scroll down the images and to manually draw the structures of interest stack-by-stack. Users can eliminate unwanted regions or split structures (i.e., branches from different neurons that are too close each other, but, to the experienced eye, clearly belong to a unique cell), to view the object in 3D and save the results obtained. The tool can be used for testing the performance of a single-neuron segmentation algorithm or to extract complex objects, where the available automated methods still fail. Here we describe the software's main features and then show an example of how ManSegTool can be used to segment neuron images acquired using a confocal microscope. In particular, expert neuroscientists were asked to segment different neurons from which morphometric variables were subsequently extracted as a benchmark for precision. In addition, a literature-defined index for evaluating the goodness of segmentation was used as a benchmark for accuracy. Neocortical layer axons from a DIADEM challenge dataset were also segmented with ManSegTool and compared with the manual "gold-standard" generated for the competition.
Constraint-based semi-autonomy for unmanned ground vehicles using local sensing
NASA Astrophysics Data System (ADS)
Anderson, Sterling J.; Karumanchi, Sisir B.; Johnson, Bryan; Perlin, Victor; Rohde, Mitchell; Iagnemma, Karl
2012-06-01
Teleoperated vehicles are playing an increasingly important role in a variety of military functions. While advantageous in many respects over their manned counterparts, these vehicles also pose unique challenges when it comes to safely avoiding obstacles. Not only must operators cope with difficulties inherent to the manned driving task, but they must also perform many of the same functions with a restricted field of view, limited depth perception, potentially disorienting camera viewpoints, and significant time delays. In this work, a constraint-based method for enhancing operator performance by seamlessly coordinating human and controller commands is presented. This method uses onboard LIDAR sensing to identify environmental hazards, designs a collision-free path homotopy traversing that environment, and coordinates the control commands of a driver and an onboard controller to ensure that the vehicle trajectory remains within a safe homotopy. This system's performance is demonstrated via off-road teleoperation of a Kawasaki Mule in an open field among obstacles. In these tests, the system safely avoids collisions and maintains vehicle stability even in the presence of "routine" operator error, loss of operator attention, and complete loss of communications.
Manned remote work station development article, executive summary
NASA Technical Reports Server (NTRS)
1979-01-01
The mission requirements for the manned remote work station (MRWS) flight article and the manned remote work station open cherry picker development test article is defined. Considerations are given for the near, mid, and far term use of the MRWS with emphasis on its ultimate application: constructing the Solar Power Satellite.
Checkout and Standard Use Procedures for the Mark III Space Suit Assembly
NASA Technical Reports Server (NTRS)
Valish, Dana J.
2012-01-01
The operational pressure range is the range to which the suit can be nominally operated for manned testing. The top end of the nominal operational pressure range is equivalent to 1/2 the proof pressure. Structural pressure is 1.5 times the specified test pressure for any given test. Proof pressure is the maximum unmanned pressure to which the suit was tested by the vendor prior to delivery. The maximum allowable working pressure (MAWP) is 90% of the proof pressure. The pressure systems RVs are set to keep components below their MAWPs. If the suit is pressurized over its MAWP, the suit will be taken out of service and an in-depth inspection/review of the suit will be performed before the suit is put back in service. The procedures outlined in this document should be followed as written. However, the suit test engineer (STE) may make redline changes real-time, provided those changes are recorded in the anomaly section of the test data sheet. If technicians supporting suit build-up, check-out, and/or test execution believe that a procedure can be improved, they should notify their lead. If procedures are incorrect to the point of potentially causing hardware damage or affecting safety, bring the problem to the technician lead and/or STE s attention and stop work until a solution (temporary or permanent) is authorized. Certain steps in the procedure are marked with a DV , for Designated Verifier. The Designated Verifier for this procedure is an Advanced Space Suit Technology Development Laboratory technician, not directly involved in performing the procedural steps, who will verify that the step was performed as stated. The steps to be verified by the DV were selected based on one or more of the following criteria: the step was deemed significant in ensuring the safe performance of the test, the data recorded in the step is of specific interest in monitoring the suit system operation, or the step has a strong influence on the successful completion of test objectives. Prior to all manned test activities, Advanced Suit Test Data Sheet (TDS) Parts A-E shall be completed to verify system and team are ready for test. Advanced Suit TDS Parts F-G shall be completed at the end of the suited activity. Appendix B identifies tha appropriate Mark III suit emergency event procedures.
Aptitude and Trait Predictors of Manned and Unmanned Aircraft Pilot Job Performance
2016-04-22
actually fly RPAs. To address this gap, the present study evaluated pre-accession trait (Big Five personality domains) and aptitude (spatial...knowledge, and personality traits that predict successful job performance for manned aircraft pilots also predict successful job performance for RPA...aptitude and personality traits , job performance, remotely-piloted aircraft, unmanned aircraft systems 16. SECURITY CLASSIFICATION OF: 17
Study of Odours and taste for Space Food
NASA Astrophysics Data System (ADS)
Katayama, Naomi; Space Agriculture Task Force; Nakata, Seiichi; Teranishi, Masaaki; Sone, Michihiko; Nakashima, Tsutomu; Hamajima, Nobuyuki; Ito, Yoshihiro
2012-07-01
The sense of taste and smell come under some kind of influences in the space environment. In the space, the astronaut was changed their food habits from light taste and smell food to like strong taste and smells food. When an astronaut live in the space comes to have weak bone like osteoporosis. It may become the physiologic condition like the old man on the earth. Therefore this study performed fact-finding of the smell and the taste in the old man on the earth as test bed of astronaut in space. Based on this finding, it was intended to predict the taste and the olfactory change of the astronaut in the space. The study included 179 males and 251 females aged 30-90 years in Yakumo Town, Hokkaido, Japan. Odours were tested using a ``standard odours by odour stick identification''method of organoleptic testing. Taste were tested using a ``standard taste by taste disc identification'' method of chemical testing. Correct answers for identification odours consisted of average 6.0±3.0 in male subjects and average 6.9±2.8 in female subjects. Correct answers for identification of sweet taste consisted of 81% males and 87% females, salty taste consisted of 86% males and 91%, sour taste consisted of 75% males and 78% females, bitter taste consisted of 76% males and 88% females. It became clear that overall approximately 20% were in some kind of abnormality in sense of smell and taste. I want to perform the investigation that continued more in future.
Design and landing dynamic analysis of reusable landing leg for a near-space manned capsule
NASA Astrophysics Data System (ADS)
Yue, Shuai; Nie, Hong; Zhang, Ming; Wei, Xiaohui; Gan, Shengyong
2018-06-01
To improve the landing performance of a near-space manned capsule under various landing conditions, a novel landing system is designed that employs double chamber and single chamber dampers in the primary and auxiliary struts, respectively. A dynamic model of the landing system is established, and the damper parameters are determined by employing the design method. A single-leg drop test with different initial pitch angles is then conducted to compare and validate the simulation model. Based on the validated simulation model, seven critical landing conditions regarding nine crucial landing responses are found by combining the radial basis function (RBF) surrogate model and adaptive simulated annealing (ASA) optimization method. Subsequently, the adaptability of the landing system under critical landing conditions is analyzed. The results show that the simulation effectively results match the test results, which validates the accuracy of the dynamic model. In addition, all of the crucial responses under their corresponding critical landing conditions satisfy the design specifications, demonstrating the feasibility of the landing system.
Improved self-contained breathing apparatus concept. Final report Oct 80-Jun 82
DOE Office of Scientific and Technical Information (OSTI.GOV)
White, L.; Walker, J.
1982-08-01
Past operational experiences of USAF fire fighting and rescue teams have indicated the need for an improved self-contained breathing apparatus (SCBA). In October 1980, a contract was awarded to Electronic Data Systems, Panama City, Florida, to design and develop a prototype SCBA that would meet Air Force technical requirements. A prototype was designed, developed, and tested through a subcontract with Reimers Consultants, Falls Church, Virginia. This report describes the technical requirements, a detailed technical description of the unit, and the unmanned test procedures and results. The unmanned testing demonstrate that the prototype SCBA meets all performance requirements, except for weight.more » The fully charged prototype weights 34 pounds, the maximum acceptable weight is 30 pounds. With the other performance requirements either met or exceeded, manned testing of the SCBA can proceed.« less
1984-06-01
emostraion. Tese eserch ool wee deignted and experimental demonstrations wre successfully con- for demonstrations. These research tools wre designated ...Topics 4.02 Instructional Systems Design Methodology Instructional Systems Development and Effectiveness Evaluation .................................... 1...6 53 0 0 67w Report Page 10.07 Human Performance Variables/Factors 10.08 Man-Machine Design Methodology Computer Assisted Methods for Human
Unilateral visual neglect overcome by cues implicit in stimulus arrays.
Kartsounis, L D; Warrington, E K
1989-01-01
The case of a man with a right hemisphere lesion and with evidence of left-sided visuospatial neglect is reported. On a variety of verbal and nonverbal tasks his performance was significantly modified by information implicit in stimulus configurations. Neglect deficits were present on tests involving spatially distinct or meaningless stimulus arrays but almost absent when stimuli were continuous or meaningfully integrated. PMID:2592968
Optimizing Orbital Debris Monitoring with Optical Telescopes
2010-09-01
poses an increasing risk to manned space missions and operational satellites ; however, the majority of debris large enough to cause catastrophic...cameras hosted on GEO- based satellites for monitoring GEO. Performance analysis indicates significant potential contributions of these systems as a...concerns over the long term-viability of the space environment and the resulting economic impacts. The 2007 China anti- satellite test and the 2009
Tsuyuguchi, Kazunari; Nagai, Hideaki; Ogawa, Kenji; Matsumoto, Tomoshige; Morimoto, Kozo; Takaki, Akiko; Mitarai, Satoshi
2017-02-01
Xpert MTB/RIF is an automated nucleic acid amplification test (NAT) that can detect the presence of Mycobacterium tuberculosis complex (MTC) in clinical specimens as well as rifampicin (RIF) resistance resulting from rpoB mutation. Despite its high sensitivity and specificity for diagnosing tuberculosis (TB) with or without RIF resistance, the clinical performance of the test is variable. In this study, we evaluated the performance of Xpert MTB/RIF in a setting of moderate TB burden and high medical resources. A total of 427 sputum specimens were obtained from 237 suspected TB cases. Of these, 159 were identified as active TB, while the other 78 were non-TB diseases. The overall sensitivity and specificity of MTC detection by Xpert MTB/RIF using culture results as a reference were 86.8% [95% confidence interval (CI): 81.8%-90.6%] and 96.8% (95% CI: 93.1%-98.5%), respectively. Among MTC-positive culture specimens, Xpert MTB/RIF positivity was 95.2% (95% CI: 91.2%-97.5%) in smear-positive and 44.7% (95% CI 30.1-60.3) in smear-negative specimens. Xpert MTB/RIF was similar to other NATs (TaqMan MTB and TRCRapid M.TB) in terms of performance. Xpert MTB/RIF detected 25 RIF-resistant isolates as compared to 22 with the mycobacterial growth indicator tube antimicrobial susceptibility testing system, yielding a sensitivity of 100% (95% CI: 85.1%-100%) and specificity of 98.3% (95% CI: 95.1%-99.4%). These results indicate that although sensitivity in smear-negative/culture-positive specimens was relatively low, Xpert MTB/RIF is a useful diagnostic tool for detecting TB and RIF resistance even in settings of moderate TB burden. Copyright © 2016. Published by Elsevier Ltd.
Computer-Based Arithmetic Test Generation
ERIC Educational Resources Information Center
Trocchi, Robert F.
1973-01-01
The computer can be a welcome partner in the instructional process, but only if there is man-machine interaction. Man should not compromise system design because of available hardware; the computer must fit the system design for the result to represent an acceptable solution to instructional technology. The Arithmetic Test Generator system fits…
Glover, William A; Atienza, Ederlyn E; Nesbitt, Shannon; Kim, Woo J; Castor, Jared; Cook, Linda; Jerome, Keith R
2016-01-01
Quantitative DNA detection of cytomegalovirus (CMV) and BK virus (BKV) is critical in the management of transplant patients. Quantitative laboratory-developed procedures for CMV and BKV have been described in which much of the processing is automated, resulting in rapid, reproducible, and high-throughput testing of transplant patients. To increase the efficiency of such assays, the performance and stability of four commercial preassembled frozen fast qPCR master mixes (Roche FastStart Universal Probe Master Mix with Rox, Bio-Rad SsoFast Probes Supermix with Rox, Life Technologies TaqMan FastAdvanced Master Mix, and Life Technologies Fast Universal PCR Master Mix), in combination with in-house designed primers and probes, was evaluated using controls and standards from standard CMV and BK assays. A subsequent parallel evaluation using patient samples was performed comparing the performance of freshly prepared assay mixes versus aliquoted frozen master mixes made with two of the fast qPCR mixes (Life Technologies TaqMan FastAdvanced Master Mix, and Bio-Rad SsoFast Probes Supermix with Rox), chosen based on their performance and compatibility with existing PCR cycling conditions. The data demonstrate that the frozen master mixes retain excellent performance over a period of at least 10 weeks. During the parallel testing using clinical specimens, no difference in quantitative results was observed between the preassembled frozen master mixes and freshly prepared master mixes. Preassembled fast real-time qPCR frozen master mixes perform well and represent an additional strategy laboratories can implement to reduce assay preparation times, and to minimize technical errors and effort necessary to perform clinical PCR. © 2015 Wiley Periodicals, Inc.
Determination of UAV pre-flight Checklist for flight test purpose using qualitative failure analysis
NASA Astrophysics Data System (ADS)
Hendarko; Indriyanto, T.; Syardianto; Maulana, F. A.
2018-05-01
Safety aspects are of paramount importance in flight, especially in flight test phase. Before performing any flight tests of either manned or unmanned aircraft, one should include pre-flight checklists as a required safety document in the flight test plan. This paper reports on the development of a new approach for determination of pre-flight checklists for UAV flight test based on aircraft’s failure analysis. The Lapan’s LSA (Light Surveillance Aircraft) is used as a study case, assuming this aircraft has been transformed into the unmanned version. Failure analysis is performed on LSA using fault tree analysis (FTA) method. Analysis is focused on propulsion system and flight control system, which fail of these systems will lead to catastrophic events. Pre-flight checklist of the UAV is then constructed based on the basic causes obtained from failure analysis.
NASA Technical Reports Server (NTRS)
Holder, Donald W., Jr.; Bagdigian, Robert M.
1992-01-01
A series of tests has been conducted at the NASA Marshall Space Flight Center (MSFC) to evaluate the performance of a Space Station Freedom (SSF) pre-development water recovery system. Potable, hygiene, and urine reclamation subsystems were integrated with end-use equipment items and successfully operated for a total of 35 days, including 23 days in closed-loop mode with man-in-the-loop. Although several significant subsystem physical anomalies were encountered, reclaimed potable and hygiene water routinely met current SSF water quality specifications. This paper summarizes the test objectives, system design, test activities/protocols, significant results/anomalies, and major lessons learned.
Technology developments integrating a space network communications testbed
NASA Technical Reports Server (NTRS)
Kwong, Winston; Jennings, Esther; Clare, Loren; Leang, Dee
2006-01-01
As future manned and robotic space explorations missions involve more complex systems, it is essential to verify, validate, and optimize such systems through simulation and emulation in a low cost testbed environment. The goal of such a testbed is to perform detailed testing of advanced space and ground communications networks, technologies, and client applications that are essential for future space exploration missions. We describe the development of new technologies enhancing our Multi-mission Advanced Communications Hybrid Environment for Test and Evaluation (MACHETE) that enables its integration in a distributed space communications testbed. MACHETE combines orbital modeling, link analysis, and protocol and service modeling to quantify system performance based on comprehensive considerations of different aspects of space missions.
Chang, Joy; Omuomo, Kenneth; Anyango, Emily; Kingwara, Leonard; Basiye, Frank; Morwabe, Alex; Shanmugam, Vedapuri; Nguyen, Shon; Sabatier, Jennifer; Zeh, Clement; Ellenberger, Dennis
2016-01-01
Timely diagnosis and treatment of infants infected with HIV are critical for reducing infant mortality. High-throughput automated diagnostic tests like Roche COBAS AmpliPrep/COBAS TaqMan HIV-1 Qual Test (Roche CAPCTM Qual) and the Abbott Real Time HIV-1 Qualitative (Abbott Qualitative) can be used to rapidly expand early infant diagnosis testing services. In this study, the performance characteristics of the Abbott Qualitative were evaluated using two hundred dried blood spots (DBS) samples (100 HIV-1 positive and 100 HIV-1 negative) collected from infants attending the antenatal facilities in Kisumu, Kenya. The Abbott Qualitative results were compared to the diagnostic testing completed using the Roche CAPCTM Qual in Kenya. The sensitivity and specificity of the Abbott Qualitative were 99.0% (95% CI: 95.0–100.0) and 100.0% (95% CI: 96.0–100.0), respectively, and the overall reproducibility was 98.0% (95% CI: 86.0–100.0). The limits of detection for the Abbott Qualitative and Roche CAPCTM Qual were 56.5 and 6.9 copies/mL at 95% CIs (p = 0.005), respectively. The study findings demonstrate that the Abbott Qualitative test is a practical option for timely diagnosis of HIV in infants. PMID:24726703
Chang, Joy; Omuomo, Kenneth; Anyango, Emily; Kingwara, Leonard; Basiye, Frank; Morwabe, Alex; Shanmugam, Vedapuri; Nguyen, Shon; Sabatier, Jennifer; Zeh, Clement; Ellenberger, Dennis
2014-08-01
Timely diagnosis and treatment of infants infected with HIV are critical for reducing infant mortality. High-throughput automated diagnostic tests like Roche COBAS AmpliPrep/COBAS TaqMan HIV-1 Qual Test (Roche CAPCTM Qual) and the Abbott Real Time HIV-1 Qualitative (Abbott Qualitative) can be used to rapidly expand early infant diagnosis testing services. In this study, the performance characteristics of the Abbott Qualitative were evaluated using two hundred dried blood spots (DBS) samples (100 HIV-1 positive and 100 HIV-1 negative) collected from infants attending the antenatal facilities in Kisumu, Kenya. The Abbott Qualitative results were compared to the diagnostic testing completed using the Roche CAPCTM Qual in Kenya. The sensitivity and specificity of the Abbott Qualitative were 99.0% (95% CI: 95.0-100.0) and 100.0% (95% CI: 96.0-100.0), respectively, and the overall reproducibility was 98.0% (95% CI: 86.0-100.0). The limits of detection for the Abbott Qualitative and Roche CAPCTM Qual were 56.5 and 6.9copies/mL at 95% CIs (p=0.005), respectively. The study findings demonstrate that the Abbott Qualitative test is a practical option for timely diagnosis of HIV in infants. Published by Elsevier B.V.
Ballistic Performance of Porous-Ceramic, Thermal-Protection-Systems
NASA Technical Reports Server (NTRS)
Christiansen, E. L.; Davis, B. A.; Miller, J. E.; Bohl, W. E.; Foreman, C. D.
2009-01-01
Porous-ceramic, thermal protection systems are used heavily in current reentry vehicles like the Space Shuttle and are currently being proposed for the next generation of manned spacecraft, Orion. These materials insulate the structural components of a spacecraft against the intense thermal environments of atmospheric reentry. Furthermore, these materials are also highly exposed to space environmental hazards like meteoroid and orbital debris impacts. This paper discusses recent impact testing up to 9 km/s, and the findings of the influence of material equation-of-state on the simulation of the impact event to characterize the ballistic performance of these materials. These results will be compared with heritage models1 for these materials developed from testing at lower velocities. Assessments of predicted spacecraft risk based upon these tests and simulations will also be discussed.
Code of Federal Regulations, 2010 CFR
2010-10-01
... 42 Public Health 1 2010-10-01 2010-10-01 false Man test for gases and vapors; Type C supplied-air respirators, demand and pressure-demand classes; test requirements. 84.163 Section 84.163 Public Health PUBLIC HEALTH SERVICE, DEPARTMENT OF HEALTH AND HUMAN SERVICES OCCUPATIONAL SAFETY AND HEALTH RESEARCH AND RELATED ACTIVITIES APPROVAL OF...
Carbon dioxide and water vapor high temperature electrolysis
NASA Technical Reports Server (NTRS)
Isenberg, Arnold O.; Verostko, Charles E.
1989-01-01
The design, fabrication, breadboard testing, and the data base obtained for solid oxide electrolysis systems that have applications for planetary manned missions and habitats are reviewed. The breadboard tested contains sixteen tubular cells in a closely packed bundle for the electrolysis of carbon dioxide and water vapor. The discussion covers energy requirements, volume, weight, and operational characteristics related to the measurement of the reactant and product gas compositions, temperature distribution along the electrolyzer tubular cells and through the bundle, and thermal energy losses. The reliability of individual cell performance in the bundle configuration is assessed.
DOT National Transportation Integrated Search
1974-08-01
Volume 3 describes the methodology for man-machine task allocation. It contains a description of man and machine performance capabilities and an explanation of the methodology employed to allocate tasks to human or automated resources. It also presen...
1981-12-01
During 1980 and the first half of 1981, the Marshall Space Flight Center conducted studies concerned with a relatively low-cost, near-term, manned space platform to satisfy current user needs, yet capable of evolutionary growth to meet future needs. The Science and Application Manned Space Platform (SAMSP) studies were to serve as a test bed for developing scientific and operational capabilities required by later, more advanced manned platforms while accomplishing early science and operations. This concept illustrates a manned space platform.
Ethnic Differences in the Goodenough-Harris Draw-a-Man and Draw-a-Woman Tests.
ERIC Educational Resources Information Center
Dugdale, A. E.; Chen, S. T.
1979-01-01
The draw-a-man (DAM) and draw-a-woman (DAW) tests were given to 307 school children in Petaling Jaya, Malaysia. The children were ethnically Malay, Chinese, or Indian (Tamil), and all came from lower socioeconomic groups. Journal availability: British Medical Journal, 1172 Commonwealth Ave., Boston, MA 02134. (Author)
Hussain, Asif; Budhota, Aamani; Hughes, Charmayne Mary Lee; Dailey, Wayne D; Vishwanath, Deshmukh A; Kuah, Christopher W K; Yam, Lester H L; Loh, Yong J; Xiang, Liming; Chua, Karen S G; Burdet, Etienne; Campolo, Domenico
2016-01-01
Technology aided measures offer a sensitive, accurate and time-efficient approach for the assessment of sensorimotor function after neurological insult compared to standard clinical assessments. This study investigated the sensitivity of robotic measures to capture differences in planar reaching movements as a function of neurological status (stroke, healthy), direction (front, ipsilateral, contralateral), movement segment (outbound, inbound), and time (baseline, post-training, 2-week follow-up) using a planar, two-degrees of freedom, robotic-manipulator (H-Man). Twelve chronic stroke (age: 55 ± 10.0 years, 5 female, 7 male, time since stroke: 11.2 ± 6.0 months) and nine aged-matched healthy participants (age: 53 ± 4.3 years, 5 female, 4 male) participated in this study. Both healthy and stroke participants performed planar reaching movements in contralateral, ipsilateral and front directions with the H-Man, and the robotic measures, spectral arc length (SAL), normalized time to peak velocities ( T peakN ), and root-mean square error (RMSE) were evaluated. Healthy participants went through a one-off session of assessment to investigate the baseline. Stroke participants completed a 2-week intensive robotic training plus standard arm therapy (8 × 90 min sessions). Motor function for stroke participants was evaluated prior to training (baseline, week-0), immediately following training (post-training, week-2), and 2-weeks after training (follow-up, week-4) using robotic assessment and the clinical measures Fugl-Meyer Assessment (FMA), Activity-Research-Arm Test (ARAT), and grip-strength. Robotic assessments were able to capture differences due to neurological status, movement direction, and movement segment. Movements performed by stroke participants were less-smooth, featured longer T peakN , and larger RMSE values, compared to healthy controls. Significant movement direction differences were observed, with improved reaching performance for the front, compared to ipsilateral and contralateral movement directions. There were group differences depending on movement segment. Outbound reaching movements were smoother and featured longer T peakN values than inbound movements for control participants, whereas SAL, T peakN , and RMSE values were similar regardless of movement segment for stroke patients. Significant change in performance was observed between initial and post-assessments using H-Man in stroke participants, compared to conventional scales which showed no significant difference. Results of the study indicate the potential of H-Man as a sensitive tool for tracking changes in performance compared to ordinal scales (i.e., FM, ARAT).
A micro-UAS to start prescribed fires
Beachly, Evan; Higgins, James; Laney, Christian; Elbaum, Sebastian; Detweiler, Carrick; Allen, Craig R.; Twidwell, Dirac
2017-01-01
Prescribed fires have many benefits, but existing ignition methods are dangerous, costly, or inefficient. This paper presents the design and evaluation of a micro-UAS that can start a prescribed fire from the air, while being operated from a safe distance and without the costs associated with aerial ignition from a manned aircraft. We evaluate the performance of the system in extensive controlled tests indoors. We verify the capabilities of the system to perform interior ignitions, a normally dangerous task, through the ignition of two prescribed fires alongside wildland firefighters.
Naserpour Farivar, Taghi; Najafipour, Reza; Johari, Pouran; Aslanimehr, Masoumeh; Peymani, Amir; Jahani Hashemi, Hoasan; Mirzaui, Baman
2014-10-01
We developed and evaluated the utility of a quadruplex Taqman real-time PCR assay that allows simultaneous identification of vancomycin-resistant genotypes and clinically relevant enterococci. The specificity of the assay was tested using reference strains of vancomycin-resistant and susceptible enterococci. In total, 193 clinical isolates were identified and subsequently genotyped using a Quadruplex Taqman real-time PCR assay and melting curve analysis. Representative Quadruplex Taqman real-time PCR amplification curve were obtained for Enterococcus faecium, Enterococcus faecalis, vanA-containing E. faecium, vanB-containing E. faecalis. Phenotypic and genotypic analysis of the isolates gave same results for 82 enterococcal isolates, while in 5 isolates, they were inconsistent. We had three mixed strains, which were detected by the TaqMan real-time PCR assay and could not be identified correctly using phenotypic methods. Vancomycin resistant enterococci (VRE) genotyping and identification of clinically relevant enterococci were rapidly and correctly performed using TaqMan real-time multiplex real-time PCR assay.
NASA Technical Reports Server (NTRS)
Hammack, Jerome B.; Heberlig, Jack C.
1961-01-01
The Mercury-Redstone program is reviewed as to its intended mission and its main results. The progressive results of unmanned, animal, and manned flights of this over-all Project Mercury ballistic training program are presented. A technical description of the major spacecraft systems is presented with some analysis of flight performance. Performance of the spacecraft with and without pilot input is discussed. The influence of the astronaut as an operating link in the over-all system is presented, and relative difficulties of manned versus unmanned flight are briefly commented upon. The program provided information on man as an integral part of a space flight system, demonstrating that man can assume a primary role in space as he does in other realms of flight. The Mercury-Redstone program demonstrated that the Mercury spacecraft was capable of manned space flight, and succeeded in partially qualifying the spacecraft for orbital flight.
Code of Federal Regulations, 2010 CFR
2010-10-01
... 42 Public Health 1 2010-10-01 2010-10-01 false Man test for gases and vapors; Type C respirators, continuous-flow class and Type CE supplied-air respirators; test requirements. 84.162 Section 84.162 Public Health PUBLIC HEALTH SERVICE, DEPARTMENT OF HEALTH AND HUMAN SERVICES OCCUPATIONAL SAFETY AND HEALTH RESEARCH AND RELATED ACTIVITIES APPROVAL...
An evaluative model of system performance in manned teleoperational systems
NASA Technical Reports Server (NTRS)
Haines, Richard F.
1989-01-01
Manned teleoperational systems are used in aerospace operations in which humans must interact with machines remotely. Manual guidance of remotely piloted vehicles, controling a wind tunnel, carrying out a scientific procedure remotely are examples of teleoperations. A four input parameter throughput (Tp) model is presented which can be used to evaluate complex, manned, teleoperations-based systems and make critical comparisons among candidate control systems. The first two parameters of this model deal with nominal (A) and off-nominal (B) predicted events while the last two focus on measured events of two types, human performance (C) and system performance (D). Digital simulations showed that the expression A(1-B)/C+D) produced the greatest homogeneity of variance and distribution symmetry. Results from a recently completed manned life science telescience experiment will be used to further validate the model. Complex, interacting teleoperational systems may be systematically evaluated using this expression much like a computer benchmark is used.
The Great Personhole Cover Debate Revisited: A Test of the Generic "Man."
ERIC Educational Resources Information Center
Cooper, Anne Messerly
In an attempt to determine whether the generic "man" has a strong association with maleness, 307 college students (122 males and 185 females) were polled to assess their attitudes about whether people "outgrow" the limited definition of man or whether the generic still retains an exclusionary, "mostly males" coloring. In order to prevent the…
Asia, Saba; Vaziri Nasab, Hamed; Sabbaghian, Marjan; Kalantari, Hamid; Zari Moradi, Shabnam; Gourabi, Hamid; Mohseni Meybodi, Anahita
2014-01-01
Complex chromosomal rearrangements (CCRs) are rare events involving more than two chromosomes and over two breakpoints. They are usually associated with infertility or sub fertility in male carriers. Here we report a novel case of a CCR in a 30-year-old oligoasthenosperm man with a history of varicocelectomy, normal testes size and normal endocrinology profile referred for chromosome analysis to the Genetics unit of Royan Reproductive Biomedicine Research Center. Chromosomal analysis was performed using peripheral blood lymphocyte cultures and analyzed by GTG banding. Additional tests such as C-banding and multicolor fluorescence in situ hybridization (FISH) procedure for each of the involved chromosomes were performed to determine the patterns of the segregations. Y chromosome microdeletions in the azoospermia factor (AZF) region were analyzed with multiplex polymerase chain reaction. To identify the history and origin of this CCR, all the family members were analyzed. No micro deletion in Y chromosome was detected. The same de novo reciprocal exchange was also found in his monozygous twin brother. The other siblings and parents were normal. CCRs are associated with male infertility as a result of spermatogenic disruption due to complex meiotic configurations and the production of chromosomally abnormal sperms. These chromosomal rearrangements might have an influence on decreasing the number of sperms. PMID:24611143
Astronaut Owen Garriott - Test Subject - Human Vestibular Function Experiment
1973-08-09
S73-34171 (9 Aug. 1973) --- Scientist-astronaut Owen K. Garriott, Skylab 3 science pilot, serves as test subject for the Skylab ?Human Vestibular Function? M131 Experiment, as seen in this photographic reproduction taken from a television transmission made by a color TV camera aboard the Skylab space station in Earth orbit. The objectives of the Skylab M131 experiment are to obtain data pertinent to establishing the validity of measurements of specific behavioral/physiological responses influenced by vestibular activity under one-g and zero-g conditions; to determine man?s adaptability to unusual vestibular conditions and predict habitability of future spacecraft conditions involving reduced gravity and Coriollis forces; and to measure the accuracy and variability in man?s judgment of spatial coordinates based on atypical gravity receptor cues and inadequate visual cures. Dr. Garriott is seated in the experiment?s litter chair which can rotate the test subject at predetermined rotational velocity or programmed acceleration/decelerational profile. Photo credit: NASA
NASA Astrophysics Data System (ADS)
Hagemann, M. W.; Gleason, C. J.; Durand, M. T.
2017-11-01
The forthcoming Surface Water and Ocean Topography (SWOT) NASA satellite mission will measure water surface width, height, and slope of major rivers worldwide. The resulting data could provide an unprecedented account of river discharge at continental scales, but reliable methods need to be identified prior to launch. Here we present a novel algorithm for discharge estimation from only remotely sensed stream width, slope, and height at multiple locations along a mass-conserved river segment. The algorithm, termed the Bayesian AMHG-Manning (BAM) algorithm, implements a Bayesian formulation of streamflow uncertainty using a combination of Manning's equation and at-many-stations hydraulic geometry (AMHG). Bayesian methods provide a statistically defensible approach to generating discharge estimates in a physically underconstrained system but rely on prior distributions that quantify the a priori uncertainty of unknown quantities including discharge and hydraulic equation parameters. These were obtained from literature-reported values and from a USGS data set of acoustic Doppler current profiler (ADCP) measurements at USGS stream gauges. A data set of simulated widths, slopes, and heights from 19 rivers was used to evaluate the algorithms using a set of performance metrics. Results across the 19 rivers indicate an improvement in performance of BAM over previously tested methods and highlight a path forward in solving discharge estimation using solely satellite remote sensing.
Mission requirements CSM-111/DM-2 Apollo/Soyuz test project
NASA Technical Reports Server (NTRS)
Blackmer, S. M.
1974-01-01
Test systems are developed for rendezvous and docking of manned spacecraft and stations that are suitable for use as a standard international system. This includes the rendezvous and docking of Apollo and Soyuz spacecraft, and crew transfer. The conduct of the mission will include: (1) testing of compatible rendezvous systems in orbit; (2) testing of universal docking assemblies; (3) verifying the techniques for transfer of cosmonauts and astronauts; (4) performing certain activities by U.S.A. and U.S.S.R. crews in joint flight; and (5) gaining of experience in conducting joint flights by U.S.A. and U.S.S.R. spacecraft, including, in case of necessity, rendering aid in emergency situations.
EMU processing - A myth dispelled
NASA Technical Reports Server (NTRS)
Peacock, Paul R.; Wilde, Richard C.; Lutz, Glenn C.; Melgares, Michael A.
1991-01-01
The refurbishment-and-checkout 'processing' activities entailed by the Space Shuttle Extravehicular Mobility Units (EMUs) are currently significantly more modest, at 1050 man-hours, than when Space Shuttle services began (involving about 4000 man-hours). This great improvement in hardware efficiency is due to the design or modification of test rigs for simplification of procedures, as well as those procedures' standardization, in conjunction with an increase in hardware confidence which has allowed the extension of inspection, service, and testing intervals. Recent simplification of the hardware-processing sequence could reduce EMU processing requirements to 600 man-hours in the near future.
MONTE CARLO STUDY OF THE CARDIAC ABSORBED DOSE DURING X-RAY EXAMINATION OF AN ADULT PATIENT.
Kadri, O; Manai, K; Alfuraih, A
2016-12-01
The computational voxel phantom 'High-Definition Reference Korean-Man (HDRK-Man)' was implemented into the Monte Carlo transport toolkit Geant4. The voxel model, adjusted to the Reference Korean Man, is 171 cm in height and 68 kg in weight and composed of ∼30 million voxels whose size is 1.981 × 1.981 × 2.0854 mm 3 The Geant4 code is then utilised to compute the dose conversion coefficients (DCCs) expressed in absorbed dose per air kerma free in air for >30 tissues and organs, including almost all organs required in the new recommendation of the ICRP 103, due to a broad parallel beam of monoenergetic photons impinging in antero-postero direction with energy ranging from 10 to 150 keV. The computed DCCs of different organs are found to be in good agreement with data published using other simulation codes. Also, the influence of patient size on DCC values was investigated for a representative body size of the adult Korean patient population. The study was performed using five different sizes covering the range of 0.8-1.2 magnification order of the original HDRK-Man. It focussed on the computation of DCC for the human heart. Moreover, the provided DCCs were used to present an analytical parameterisation for the calculation of the cardiac absorbed dose for any arbitrary X-ray spectrum and for those patient sizes. Thus, the present work can be considered as an enhancement of the continuous studies performed by medical physicist as part of quality control tests and radiation protection dosimetry. © The Author 2015. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.
NASA Technical Reports Server (NTRS)
Bates, Lisa B.; Young, David T.
2012-01-01
This paper describes recent developmental testing to verify the integration of a developmental electromechanical actuator (EMA) with high rate lithium ion batteries and a cross platform extensible controller. Testing was performed at the Thrust Vector Control Research, Development and Qualification Laboratory at the NASA George C. Marshall Space Flight Center. Electric Thrust Vector Control (ETVC) systems like the EMA may significantly reduce recurring launch costs and complexity compared to heritage systems. Electric actuator mechanisms and control requirements across dissimilar platforms are also discussed with a focus on the similarities leveraged and differences overcome by the cross platform extensible common controller architecture.
Investigations to improve carbon dioxide control with amine and molecular sieve type sorbers
NASA Technical Reports Server (NTRS)
Bertrand, J. F.; Brose, H. F.; Kester, F. L.; Lunde, P. J.
1972-01-01
The optimization trends and operating parameters of an integral molecular sieve bed heat exchanger were investigated. The optimum combination of substrate and coating for the HS-B porous polymer was determined based on the CO2 dynamic capacity in the presence of water vapor. Full size HS-B canister performance was evaluated. An Amine CO2 Concentrator utilizing IR-45 sorber material and available Manned Orbiting Laboratory hardware was designed, fabricated and tested for use as an experiment in the NASA 90-day space simulator test of 1970. It supported four men in the simulator for 71 days out of the 90-day test duration.
Intergenerational Transmission of the Behavioral Consequences of Early Experience in Prairie Voles
Stone, Anita Iyengar; Bales, Karen Lisa
2010-01-01
We examined intergenerational and epigenetic effects of early handling manipulations on the social behavior of the prairie vole (Microtus ochrogaster), a monogamous rodent. Laboratory-born parents and their newborn pups were assigned to either a MAN0 “zero handling” manipulation (transfer with a cup during weekly cage changes) or a MAN1 “gloved handling” manipulation (transfer with a gloved hand). Previous studies from our laboratory (Bales et al. 2007) showed that MAN0 juvenile males that received this manipulation as pups are less alloparental and that MAN0 adult females that received this manipulation as pups display impaired pair-bonding. In the present study, when MAN0 and MAN1 pups reached adulthood, they were mated in three combinations (MAN1 female × MAN1 male; MAN0 female × MAN1 male; MAN1 female and MAN0 male). Once the pairs produced offspring, we examined their parental behavior towards their own pups. The offspring of these pairings (F2 generation) also were tested as juveniles for alloparental behavior. MAN1 females paired with a MAN0 male displayed higher levels of parenting behaviors. In the F2 generation, juvenile offspring with a MAN0 parent were less alloparental than were offspring from other pairs. These results suggest that early experiences can be transmitted intergenerationally. PMID:20457234
Robotic vehicle mobility and task performance: A flexible control modality for manned systems
NASA Technical Reports Server (NTRS)
Eldredge, Frederick
1994-01-01
In the early 1980's, a number of concepts were developed for applying robotics to ground systems. The majority of these early application concepts envisioned robotics technology embedded in dedicated unmanned systems; i.e., unmanned systems with no provision for direct manned control of the platform. Although these concepts offered advantages peculiar to platforms designed from the outset exclusively for unmanned operation--i.e., no crew compartment--their findings would require costs and support for a new class of unmanned systems. The current era of reduced budgets and increasing focus on rapid force projection has created new opportunities to examine the value of an alternative concept: the use of existing manned platforms with an ability to quickly shift from normal manned operation to unmanned should a particularly harzardous situation arise. The author of this paper addresses the evolution of robotic vehicle concepts and technology testbeds from exclusively unmanned systems to a variety of 'optionally manned' systems which have been designed with minimum intrusion actuator and control equipment to minimize degradation of vehicle performance in manned modes of operation.
NASA Technical Reports Server (NTRS)
Brady, J. F.
1972-01-01
Future manned space missions may require transition between artificial gravity and weightlessness environments. The frequency and rate of such transition will influence the psychophysiological responses of man. Abrupt transfers are examined between such rotating and nonrotating environments to determine the physiological and behavioral responses of man. Five subjects were tested using rates of rotation up to 5 rpm.
ERIC Educational Resources Information Center
Chicago Board of Education, IL.
Two units of Asian materials for secondary students comprise this document. The first unit presents a brief history of Asian man and his environment, including geography, climate, ethnic groups, resources, food, and population. Following the historical narrative are community references and various learning experiences and activities which further…
Water-propellant resistojets for man-tended platforms
NASA Technical Reports Server (NTRS)
Louviere, Allen J.; Jones, Robert E.; Morren, W. Earl; Sovey, James S.
1987-01-01
The selection of a propulsion system for a man-tended platform has been influenced by the planned use of resistojets for drag make-up on the manned space station. For that application a resistojet has been designed that is capable of operation with a wide variety of propellants, including water. The reasons for the selection of water as the propellant and the performance of water as a propellant are discussed. The man-tended platform and its mission requirements are described.
Muller, Laura K.; Lorch, Jeffrey M.; Lindner, Daniel L.; O'Connor, Michael; Gargas, Andrea; Blehert, David S.
2013-01-01
The fungus Geomyces destructans is the causative agent of white-nose syndrome (WNS), a disease that has killed millions of North American hibernating bats. We describe a real-time TaqMan PCR test that detects DNA from G. destructans by targeting a portion of the multicopy intergenic spacer region of the rRNA gene complex. The test is highly sensitive, consistently detecting as little as 3.3 fg of genomic DNA from G. destructans. The real-time PCR test specifically amplified genomic DNA from G. destructans but did not amplify target sequence from 54 closely related fungal isolates (including 43 Geomyces spp. isolates) associated with bats. The test was further qualified by analyzing DNA extracted from 91 bat wing skin samples, and PCR results matched histopathology findings. These data indicate the real-time TaqMan PCR method described herein is a sensitive, specific, and rapid test to detect DNA from G. destructans and provides a valuable tool for WNS diagnostics and research.
NASA Astrophysics Data System (ADS)
Vandewal, Anthony
1993-11-01
This paper provides an unclassified overview of the U.S. Army program that collects and disseminates information about the effects of battlefied smokes and obscurants on weapon system performance. The primary mechanism for collecting field data is an annual exercise called SMOKE WEEK. In SMOKE WEEK testing, a complete characterization is made of the ambient test conditions, of the electromagnetic radiation propagation in clear and obscured conditions, and of the obscuring cloud that the particles that comprise the cloud. This paper describes the instrumentation and methodology employed to make these field measurements, methods of analysis, and some typical results. The effects of these realistic battlefield environments on weapons system performance are discussed generically.
A century of wind tunnels since Eiffel
NASA Astrophysics Data System (ADS)
Chanetz, Bruno
2017-08-01
Fly higher, faster, preserve the life of test pilots and passengers, many challenges faced by man since the dawn of the twentieth century, with aviation pioneers. Contemporary of the first aerial exploits, wind tunnels, artificially recreating conditions encountered during the flight, have powerfully contributed to the progress of aeronautics. But the use of wind tunnels is not limited to aviation. The research for better performance, coupled with concern for energy saving, encourages manufacturers of ground vehicles to perform aerodynamic tests. Buildings and bridge structures are also concerned. This article deals principally with the wind tunnels built at ONERA during the last century. Somme wind tunnels outside ONERA, even outside France, are also evocated when their characteristics do not exist at ONERA.
Teleoperator Human Factors Study
NASA Technical Reports Server (NTRS)
1986-01-01
An investigation of the spectrum of space teleoperation activities likely in the 1985 to 1995 decade focused on the resolution of critical human engineering issues and characterization of the technology effect on performance of remote human operators. The study began with the identification and documentation of a set of representative reference teleoperator tasks. For each task, technology, development, and design options, issues, and alternatives that bear on human operator performance were defined and categorized. A literature survey identified existing studies of man/machine issues. For each teleoperations category, an assessment was made of the state of knowledge on a scale from adequate to void. The tests, experiments, and analyses necessary to provide the missing elements of knowledge were then defined. A limited set of tests were actually performed, including operator selection, baseline task definition, control mode study, lighting study, camera study, and preliminary time delay study.
Evaluation of sensitivity of TaqMan RT-PCR for rubella virus detection in clinical specimens.
Okamoto, Kiyoko; Mori, Yoshio; Komagome, Rika; Nagano, Hideki; Miyoshi, Masahiro; Okano, Motohiko; Aoki, Yoko; Ogura, Atsushi; Hotta, Chiemi; Ogawa, Tomoko; Saikusa, Miwako; Kodama, Hiroe; Yasui, Yoshihiro; Minagawa, Hiroko; Kurata, Takako; Kanbayashi, Daiki; Kase, Tetsuo; Murata, Sachiko; Shirabe, Komei; Hamasaki, Mitsuhiro; Kato, Takashi; Otsuki, Noriyuki; Sakata, Masafumi; Komase, Katsuhiro; Takeda, Makoto
2016-07-01
An easy and reliable assay for detection of the rubella virus is required to strengthen rubella surveillance. Although a TaqMan RT-PCR assay for detection of the rubella virus has been established in Japan, its utility for diagnostic purposes has not been tested. To allow introduction of the TaqMan RT-PCR into the rubella surveillance system in Japan, the sensitivity of the assay was determined using representative strains for all genotypes and clinical specimens. The detection limits of the method for individual genotypes were examined using viral RNA extracted from 13 representative strains. The assay was also tested at 10 prefectural laboratories in Japan, designated as local reference laboratories for measles and rubella, to allow nationwide application of the assay. The detection limits and amplification efficiencies of the assay were similar among all the representative strains of the 13 genotypes. The TaqMan RT-PCR could detect approximately 90% of throat swab and urine samples taken up to 5days of illness. These samples were determined positive by a highly sensitive nested RT-PCR. The TaqMan RT-PCR could detect at least 10 pfu of rubella virus. Although the sensitivity was somewhat lower than that of the conventional nested RT-PCR, the TaqMan RT-PCR could be more practical to routine tests for rubella laboratory diagnosis and detection in view of the rapid response and reducing risks of contamination. Copyright © 2016 Elsevier B.V. All rights reserved.
Man in space: The use of animal models
NASA Astrophysics Data System (ADS)
Ballard, Rodney W.; Souza, Kenneth A.
Animals have traditionally preceded man into space. During animal and human travels in space over the past almost 30 years, numerous anatomical, physiological, and biochemical changes have been observed. In order to safely qualify humans for extended duration space missions, scientific research needs to be performed. It may be possible to achieve many of these research goals with flight crews serving as experimental subjects; however, to do this with human subjects alone is impractical. Therefore, the use of animal surrogates as experimental subjects is essential to provide the missing information on the effects of spaceflights, to validate countermeasures, and to test medical treatment techniques which will be necessary for long duration missions. This research to assure human health, safety, and productivity in future extended duration space flights will include flights on NASA's Space Shuttle, unmanned biosatellites, and the Space Station Freedom.
Man in space: the use of animal models.
Ballard, R W; Souza, K A
1991-01-01
Animals have traditionally preceded man into space. During animal and human travels in space over the past almost 30 years, numerous anatomical, physiological, and biochemical changes have been observed. In order to safely qualify humans for extended duration space missions, scientific research needs to be performed. It may be possible to achieve many of these research goals with flight crews serving as experimental subjects; however, to do this with human subjects alone is impractical. Therefore, the use of animal surrogates as experimental subjects is essential to provide the missing information on the effects of spaceflights, to validate countermeasures, and to test medical treatment techniques which will be necessary for long duration missions. This research to assure human health, safety, and productivity in future extended duration space flights will include flights on NASA's Space Shuttle, unmanned biosatellites, and the Space Station Freedom.
NASA Technical Reports Server (NTRS)
Taff, L. G.; Beatty, D. E.; Yakutis, A. J.; Randall, P. M. S.
1985-01-01
The majority of work performed by the Lincoln Laboratory's Space Surveillance Group, at the request of NASA, to define the near-earth population of man-made debris is summarized. Electrooptical devices, each with a 1.2 deg FOV, were employed at the GEODSS facility in New Mexico. Details of the equipment calibration and alignment procedures are discussed, together with implementation of a synchronized time code for computer controlled videotaping of the imagery. Parallax and angular speed data served as bases for distinguishing between man-made debris and meteoroids. The best visibility was obtained in dawn and dusk twilight conditions at elevation ranges of 300-2000 km. Tables are provided of altitudinal density distribution of debris. It is noted that the program also yielded an extensive data base on meteoroid rates.
NASA Technical Reports Server (NTRS)
1984-01-01
The Executive Summary volume 1, includes an overview of both phases of the Definition of Technology Development Missions for Early Space Station Satellite Servicing. The primary purpose of Phase 1 of the Marshall Space Flight Center (MSFC) Satellite Servicing Phase 1 study was to establish requirements for demonstrating the capability of performing satellite servicing activities on a permanently manned Space Station in the early 1990s. The scope of Phase 1 included TDM definition, outlining of servicing objectives, derivation of initial Space Station servicing support requirements, and generation of the associated programmatic schedules and cost. The purpose of phase 2 of the satellite servicing study was to expand and refine the overall understanding of how best to use the manned space station as a test bed for demonstration of satellite servicing capabilities.
When to Perform Antenna Measurements in a Near-Field Range or a Short Tapered Chamber
2017-03-01
study was undertaken to quantify and compare electromagnetic device (i.e., antenna) measurements using the US Army Research Laboratory’s (ARL’s) near...results for future antennas under test in the most cost-effective manner (man-hours, custom mount, etc.) 15. SUBJECT TERMS electromagnetic , chamber...study was undertaken to quantify and compare electromagnetic (EM) device (i.e., antenna) measurements using the US Army Research Laboratory’s (ARL
Computerized atmospheric trace contaminant control simulation for manned spacecraft
NASA Technical Reports Server (NTRS)
Perry, J. L.
1993-01-01
Buildup of atmospheric trace contaminants in enclosed volumes such as a spacecraft may lead to potentially serious health problems for the crew members. For this reason, active control methods must be implemented to minimize the concentration of atmospheric contaminants to levels that are considered safe for prolonged, continuous exposure. Designing hardware to accomplish this has traditionally required extensive testing to characterize and select appropriate control technologies. Data collected since the Apollo project can now be used in a computerized performance simulation to predict the performance and life of contamination control hardware to allow for initial technology screening, performance prediction, and operations and contingency studies to determine the most suitable hardware approach before specific design and testing activities begin. The program, written in FORTRAN 77, provides contaminant removal rate, total mass removed, and per pass efficiency for each control device for discrete time intervals. In addition, projected cabin concentration is provided. Input and output data are manipulated using commercial spreadsheet and data graphing software. These results can then be used in analyzing hardware design parameters such as sizing and flow rate, overall process performance and program economics. Test performance may also be predicted to aid test design.
NASA Technical Reports Server (NTRS)
Steinbronn, O.
1983-01-01
The following types of space missions were evaluated to determine those that require, or will be benefited materially, by a manned space station: (1) science and applications, (2) commercial, (3) technology development, (4) space operations, and (5) national security. Integrated mission requirements for man-operated and man-tended free-flying missions were addressed. A manned space station will provide major performance and economic benefits to a wide range of missions planned for the 1990s.
Secondary Impacts on Structures on the Lunar Surface
NASA Technical Reports Server (NTRS)
Christiansen, Eric; Walker, James D.; Grosch, Donald J.
2010-01-01
The Altair Lunar Lander is being designed for the planned return to the Moon by 2020. Since it is hoped that lander components will be re-used by later missions, studies are underway to examine the exposure threat to the lander sitting on the Lunar surface for extended periods. These threats involve both direct strikes of meteoroids on the vehicle as well as strikes from Lunar regolith and rock thrown by nearby meteorite strikes. Currently, the lander design is comprised of up to 10 different types of pressure vessels. These vessels included the manned habitation module, fuel, cryogenic fuel and gas storage containers, and instrument bays. These pressure vessels have various wall designs, including various aluminum alloys, honeycomb, and carbon-fiber composite materials. For some of the vessels, shielding is being considered. This program involved the test and analysis of six pressure vessel designs, one of which included a Whipple bumper shield. In addition to the pressure vessel walls, all the pressure vessels are wrapped in multi-layer insulation (MLI). Two variants were tested without the MLI to better understand the role of the MLI in the impact performance. The tests of performed were to examine the secondary impacts on these structures as they rested on the Lunar surface. If a hypervelocity meteor were to strike the surface nearby, it would throw regolith and rock debris into the structure at a much lower velocity. Also, when the manned module departs for the return to Earth, its rocket engines throw up debris that can impact the remaining lander components and cause damage. Glass spheres were used as a stimulant for the regolith material. Impact tests were performed with a gas gun to find the V50 of various sized spheres striking the pressure vessels. The impacts were then modeled and a fast-running approximate model for the V50 data was developed. This model was for performing risk analysis to assist in the vessel design and in the identification of ideal long-term mission sites. This paper reviews the impact tests and analysis and modeling examining the impact threat to various components in the lander design.
A new one-man submarine is tested as vehicle for solid rocket booster retrieval
NASA Technical Reports Server (NTRS)
2000-01-01
The one-man submarine dubbed DeepWorker 2000 sits on the deck of Liberty Star, one of two KSC solid rocket booster recovery ships. The sub is being tested on its ability to duplicate the sometimes hazardous job United Space Alliance (USA) divers perform to recover the expended boosters in the ocean after a launch. The boosters splash down in an impact area about 140 miles east of Jacksonville and after recovery are towed back to KSC for refurbishment by the specially rigged recovery ships. DeepWorker 2000 will be used in a demonstration during retrieval operations after the upcoming STS-101 launch. The submarine pilot will demonstrate capabilities to cut tangled parachute riser lines using a manipulator arm and attach a Diver Operator Plug to extract water and provide flotation for the booster. DeepWorker 2000 was built by Nuytco Research Ltd., North Vancouver, British Columbia. It is 8.25 feet long, 5.75 feet high, and weighs 3,800 pounds. USA is a prime contractor to NASA for the Space Shuttle program.
A new one-man submarine is tested as vehicle for solid rocket booster retrieval
NASA Technical Reports Server (NTRS)
2000-01-01
From the deck of Liberty Star, one of two KSC solid rocket booster recovery ships, a crane lowers a one-man submarine into the ocean near Cape Canaveral, Fla. Called DeepWorker 2000, the sub is being tested on its ability to duplicate the sometimes hazardous job United Space Alliance (USA) divers perform to recover the expended boosters in the ocean after a launch. The boosters splash down in an impact area about 140 miles east of Jacksonville and after recovery are towed back to KSC for refurbishment by the specially rigged recovery ships. DeepWorker 2000 will be used in a demonstration during retrieval operations after the upcoming STS-101 launch. The submarine pilot will demonstrate capabilities to cut tangled parachute riser lines using a manipulator arm and attach a Diver Operator Plug to extract water and provide flotation for the booster. DeepWorker 2000 was built by Nuytco Research Ltd., North Vancouver, British Columbia. It is 8.25 feet long, 5.75 feet high, and weighs 3,800 pounds. USA is a prime contractor to NASA for the Space Shuttle program.
An unusual case of random fire-setting behavior associated with lacunar stroke.
Bosshart, Herbert; Capek, Sonia
2011-06-15
A case of a 47-year-old man with a sudden onset of a bizarre and random fire-setting behavior is reported. The man, who had been arrested on felony arson charges, complained of difficulties concentrating and of recent memory impairment. Axial T1-weighted magnetic resonance imaging showed a low intensity lacunar lesion in the genu and anterior limb of the left internal capsule. A neuropsychological test battery revealed lower than normal scores for executive functions, attention and memory, consistent with frontal lobe dysfunction. The recent onset of fire-setting behavior and the chronic nature of the lacunar lesion, together with an unremarkable performance on tests measuring executive functions two years prior, suggested a causal relationship between this organic brain lesion and the fire-setting behavior. The present case describes a rare and as yet unreported association between random impulse-driven fire-setting behavior and damage to the left internal capsule and suggests a disconnection of frontal lobe structures as a possible pathogenic mechanism. Copyright © 2011 Elsevier Ireland Ltd. All rights reserved.
Technology advancement of the static feed water electrolysis process
NASA Technical Reports Server (NTRS)
Jensen, F. C.; Schubert, F. H.
1977-01-01
Some results are presented of a research and development program to continue the development of a method to generate oxygen for crew metabolic consumption during extended manned space flights. The concept being pursued is that of static feed water electrolysis. Specific major results of the work included: (1) completion of a 30-day electrode test using a Life Systems, Inc.-developed high performance catalyst. During startup the cell voltages were as low as 1.38 V at current densities of 108 mA/sq cm (100 ASF) and temperatures of 355 K (180 F). At the end of 30 days of testing the cell voltages were still only 1.42 V at 108 mA/sq cm, (2) determination that the Static Feed Water Electrolysis Module does not release an aerosol of the cell electrolyte into the product gas streams after a break-in period of 24 hours following a new electrolyte charge, and (3) completion of a detailed design analysis of an electrochemical Oxygen Generation Subsystem at a three-man level (4.19 kg/day (9.24 lb/day) of oxygen).
[Addictive potential in man: methodological aspects].
Warot, D; Marra, D
1995-01-01
Different methods have been developed in clinical abuse liability testing in man. Tolerance, psychic and/or physical dependence must be investigated through clinical studies during drug development of a new substance. Adequate methodology is needed using double-blind, time-blind evaluations, comparisons of different dose levels and duration of treatment for a given drug, abrupt and gradual interruption of treatment, appropriate period of observation after treatment cessation ... The optimal scale to evaluate properly the symptoms occurring after drug discontinuation is still under investigation. These studies will or should permit the differentiation of rebound, withdrawal and recurrence. Methods developed to study reinforcing effects in post-addicts and healthy subjects are self-administration and choice procedures. In addition, the more traditional approach has been through assessing self-reported effects in which standardized questionnaires are used (Addiction Research Center Inventory or A.R.C.I.; Single Dose Questionnaire or S.D.Q.). A third focus of measurement has been discrimination studies performed in individuals with histories of drug abuse as well as healthy subjects. Abuse-liability testing of a new compound needs a multidimensional assessment to optimize the predictivity in defining the relative risk.
Psychophysiological investigations of the biomedical problems of manned spaceflight
NASA Technical Reports Server (NTRS)
1993-01-01
The Final Report on psychophysiological investigations of the biomedical problems of manned spaceflight is presented. In the first project, statistical analyses of human autonomic data were performed. The objectives were the following: to establish a relational data base containing human psychophysiological data obtained from Shuttle flight experiments and ground-based research over a 20 year period; to enable multi-user access and retrieval of these data for subsequent analyses and for possible inclusion in the proposed Life Sciences Data Archive; and to enable/conduct statistical analyses across several experiments on large subject populations which can thereby provide definitive answers to questions on human autonomic and behavioral responses and adaptation to environmental stressors on Earth and in space. The second project studied motion sickness. The objectives were: to test/develop hardware and procedures to be incorporated into preflight training of crewmembers of Spacelab-J; and to examine spin-off applications of AFT. The third project studied orthostatic intolerance. The objective was to test the feasibility of applying autogenic-feedback training as a potential treatment for postflight orthostatic intolerance.
Design and Verification of Critical Pressurised Windows for Manned Spaceflight
NASA Astrophysics Data System (ADS)
Lamoure, Richard; Busto, Lara; Novo, Francisco; Sinnema, Gerben; Leal, Mendes M.
2014-06-01
The Window Design for Manned Spaceflight (WDMS) project was tasked with establishing the state-of-art and explore possible improvements to the current structural integrity verification and fracture control methodologies for manned spacecraft windows.A critical review of the state-of-art in spacecraft window design, materials and verification practice was conducted. Shortcomings of the methodology in terms of analysis, inspection and testing were identified. Schemes for improving verification practices and reducing conservatism whilst maintaining the required safety levels were then proposed.An experimental materials characterisation programme was defined and carried out with the support of the 'Glass and Façade Technology Research Group', at the University of Cambridge. Results of the sample testing campaign were analysed, post-processed and subsequently applied to the design of a breadboard window demonstrator.Two Fused Silica glass window panes were procured and subjected to dedicated analyses, inspection and testing comprising both qualification and acceptance programmes specifically tailored to the objectives of the activity.Finally, main outcomes have been compiled into a Structural Verification Guide for Pressurised Windows in manned spacecraft, incorporating best practices and lessons learned throughout this project.
Integrated Energy Solutions | NREL
Transitions A man and woman standing in front of a large, color 3D visualization screen that spans the height a woman and a man testing a scaled model of a microgrid controller in a laboratory setting
Apollo Soyuz, mission evaluation report
NASA Technical Reports Server (NTRS)
1975-01-01
The Apollo Soyuz mission was the first manned space flight to be conducted jointly by two nations - the United States and the Union of Soviet Socialist Republics. The primary purpose of the mission was to test systems for rendezvous and docking of manned spacecraft that would be suitable for use as a standard international system, and to demonstrate crew transfer between spacecraft. The secondary purpose was to conduct a program of scientific and applications experimentation. With minor modifications, the Apollo and Soyuz spacecraft were like those flown on previous missions. However, a new module was built specifically for this mission - the docking module. It served as an airlock for crew transfer and as a structural base for the docking mechanism that interfaced with a similar mechanism on the Soyuz orbital module. The postflight evaluation of the performance of the docking system and docking module, as well as the overall performance of the Apollo spacecraft and experiments is presented. In addition, the mission is evaluated from the viewpoints of the flight crew, ground support operations, and biomedical operations. Descriptions of the docking mechanism, docking module, crew equipment and experiment hardware are given.
Vestibular ataxia and its measurement in man
NASA Technical Reports Server (NTRS)
Fregly, A. R.
1974-01-01
Methods involved in and results obtained with a new comprehensive ataxia test battery are described, and definitions of spontaneous and induced vestibular ataxia in man are given in terms of these findings. In addition, the topic of alcohol-induced ataxia in relation to labyrinth function is investigated. Items in the test battery comprise a sharpened Romberg test, in which the subject stands on the floor with eyes closed and arms folded against his chest, feet heel-to-toe, for 60 seconds; an eyes-open walking test; an eyes-open standing test; an eyes-closed standing test; an eyes-closed on-leg standing test; an eyes-closed walk a line test; an eyes-closed heel-to-toe walking test; and supplementary ataxia tests such as the classical Romberg test.
NASA Technical Reports Server (NTRS)
1979-01-01
The requirements for several configurations of flight articles are presented. These requirements provide the basis to design manned remote work station development test articles and establish tests and simulation objectives for the resolution of development issues. Mission system and subsystem requirements for four MRWS configurations included: open cherry picker; closed cherry picker; crane turret; and free flyer.
Optimization of Shipboard Manning Levels Using Imprint Pro Forces Module
2015-09-01
NPS-OR-15-008 NAVAL POSTGRADUATE SCHOOL MONTEREY, CALIFORNIA OPTIMIZATION OF SHIPBOARD MANNING LEVELS USING IMPRINT PRO...Optimization of Shipboard Manning Levels Using IMPRINT Pro Forces Module 5a. CONTRACT NUMBER 5b. GRANT NUMBER 5c. PROGRAM ELEMENT NUMBER...ABSTRACT The Improved Performance Research Integration Tool ( IMPRINT ) is a dynamic, stochastic, discrete-event modeling tool used to develop a model
Small reactor power systems for manned planetary surface bases
NASA Technical Reports Server (NTRS)
Bloomfield, Harvey S.
1987-01-01
A preliminary feasibility study of the potential application of small nuclear reactor space power systems to manned planetary surface base missions was conducted. The purpose of the study was to identify and assess the technology, performance, and safety issues associated with integration of reactor power systems with an evolutionary manned planetary surface exploration scenario. The requirements and characteristics of a variety of human-rated modular reactor power system configurations selected for a range of power levels from 25 kWe to hundreds of kilowatts is described. Trade-off analyses for reactor power systems utilizing both man-made and indigenous shielding materials are provided to examine performance, installation and operational safety feasibility issues. The results of this study have confirmed the preliminary feasibility of a wide variety of small reactor power plant configurations for growth oriented manned planetary surface exploration missions. The capability for power level growth with increasing manned presence, while maintaining safe radiation levels, was favorably assessed for nominal 25 to 100 kWe modular configurations. No feasibility limitations or technical barriers were identified and the use of both distance and indigenous planetary soil material for human rated radiation shielding were shown to be viable and attractive options.
Öztürk, Semi; Aktemur, Tuğba; Kalyoncuoğlu, Muhsin; Durmuş, Gündüz; Can, Mehmet
2017-04-01
A 52-year-old man complaining of persistent recurring chest pain at night underwent coronary angiogram at another institution. Normal coronaries were observed and he was discharged with muscle spasmolytic prescription. Since symptoms had continued, 24-hour Holter monitoring was ordered at our facility and results revealed huge ST elevation and polymorphic ventricular tachycardia. Cold pressor test performed in catheterization laboratory also resulted in ventricular tachycardia. Nifedipine was prescribed and follow-up Holter monitoring revealed no further vasospastic episodes. Utility of 24-hour Holter rhythm monitoring and cold pressor test in patients with recurrent chest pain at night is demonstrated in this report.
Shin, Kyung-Hwa; Lee, Hyun-Ji; Chang, Chulhun L; Kim, Hyung-Hoi
2018-04-01
Hepatitis B virus (HBV) DNA levels are used to predict the response to therapy, determine therapy initiation, monitor resistance to therapy, and establish treatment success. To verify the performance of the cobas HBV test using the cobas 4800 system for HBV DNA quantification and to compare the HBV DNA quantification ability between the cobas HBV test and COBAS AmpliPrep/COBAS TaqMan HBV version 2.0 (CAP/CTM v2.0). The precision, linearity, and limit of detection of the cobas HBV test were evaluated using the 4th World Health Organization International Standard material and plasma samples. Clinical samples that yielded quantitative results using the CAP/CTM v2.0 and cobas HBV tests were subjected to correlational analysis. Three hundred forty-nine samples were subjected to correlational analysis, among which 114 samples showed results above the lower limit of quantification. Comparable results were obtained ([cobas HBV test] = 1.038 × [CAP/CTM v2.0]-0.173, r = 0.914) in 114 samples, which yielded values above the lower limit of quantification. The results for 86.8% of the samples obtained using the cobas HBV test were within 0.5 log 10 IU/mL of the CAP/CTM v2.0 results. The total precision values against the low and high positive controls were 1.4% (mean level: 2.25 log 10 IU/mL) and 3.2% (mean level: 6.23 log 10 IU/mL), respectively. The cobas HBV test demonstrated linearity (1.15-6.75 log 10 IU/mL, y = 0.95 × 6 + 0.17, r 2 = 0.994). The cobas HBV test showed good correlation with CAP/CTM v2.0, and had good precision and an acceptable limit of detection. The cobas HBV test using the cobas 4800 is a reliable method for quantifying HBV DNA levels in the clinical setting. Copyright © 2018. Published by Elsevier B.V.
NASA Technical Reports Server (NTRS)
Bagdigian, R. M.; Traweek, M. S.; Griffith, G. K.; Griffin, M. R.
1991-01-01
A series of tests has been conducted at the NASA Marshall Space Flight Center (MSFC) to evaluate the performance of a predevelopment water recovery system. Potable, hygiene, and urine reclamation subsystems were integrated with end-use equipment items and successfully operated in open and partially closed-loop modes, with man-in-the-loop, for a total of 28 days. Several significant subsystem physical anomalies were encountered during testing. Reclaimed potable and hygiene water generally met the current Space Station Freedom (SSF) water quality specifications for inorganic and microbiological constituents, but exceeded the maximum allowable concentrations for Total Organic Carbon (TOC). This paper summarizes the test objectives, system design, test activities/protocols, significant results/anomalies, and major lessons learned.
Microbial ecology measurement system
NASA Technical Reports Server (NTRS)
1972-01-01
The sensitivity and potential rapidity of the PIA test that was demonstrated during the feasibility study warranted continuing the effort to examine the possibility of adapting this test to an automated procedure that could be used during manned missions. The effort during this program has optimized the test conditions for two important respiratory pathogens, influenza virus and Mycoplasma pneumoniae, developed a laboratory model automated detection system, and investigated a group antigen concept for virus detection. Preliminary tests on the handling of oropharygeal clinical samples for PIA testing were performed using the adenovirus system. The results obtained indicated that the PIA signal is reduced in positive samples and is increased in negative samples. Treatment with cysteine appeared to reduce nonspecific agglutination in negative samples but did not maintain the signal in positive samples.
Swan, H J
1979-12-01
Altered regional mechanical myocardial performance is an early, sensitive marker of myocardial ischemia, and can be estimated in man with reasonable accuracy. Identification, localization and quantification of abnormalities in mechanical performance can be used to predict the presence of coronary artery disease. Testing techniques that have little or no effect on diagnostic efficiency must be replaced with more sensitive indicators of ischemia. If experimental data are validated by findings in human subjects, accurate identification of regional wall motion changes during test conditions should prove to be a powerful marker of ischemia. To be of value, a diagnostic test must strongly increase the frequency of identification of subjects with a high probabilty for the presence of coronary artery disease in an otherwise low-prevalence population, and of those with known disease who are at the highest risk for complications including myocardial infarction or death.
NASA Technical Reports Server (NTRS)
Gore, Brian F.
2011-01-01
As automation and advanced technologies are introduced into transport systems ranging from the Next Generation Air Transportation System termed NextGen, to the advanced surface transportation systems as exemplified by the Intelligent Transportations Systems, to future systems designed for space exploration, there is an increased need to validly predict how the future systems will be vulnerable to error given the demands imposed by the assistive technologies. One formalized approach to study the impact of assistive technologies on the human operator in a safe and non-obtrusive manner is through the use of human performance models (HPMs). HPMs play an integral role when complex human-system designs are proposed, developed, and tested. One HPM tool termed the Man-machine Integration Design and Analysis System (MIDAS) is a NASA Ames Research Center HPM software tool that has been applied to predict human-system performance in various domains since 1986. MIDAS is a dynamic, integrated HPM and simulation environment that facilitates the design, visualization, and computational evaluation of complex man-machine system concepts in simulated operational environments. The paper will discuss a range of aviation specific applications including an approach used to model human error for NASA s Aviation Safety Program, and what-if analyses to evaluate flight deck technologies for NextGen operations. This chapter will culminate by raising two challenges for the field of predictive HPMs for complex human-system designs that evaluate assistive technologies: that of (1) model transparency and (2) model validation.
Hot air balloons fill gap in atmospheric and sensing platforms
NASA Astrophysics Data System (ADS)
Watson, Steven M.; Price, Russ
Eric Edgerton was having a problem he could not solve: how to noninvasively collect in situ incinerator plume data. So he called in the Air Force and learned about its Atmospheric and Sensor Test Platform program; its platform is a manned hot air balloon. Many investigators are discovering the advantages of hot air balloons as stable, inexpensive platforms for performing in situ atmospheric measurements. Some are also using remote sensing capabilities on the balloon platforms.
Variable Inhibition by Falling CO2 of Hypoxic Ventilatory Response in Man,
1983-06-21
alkalosis which, in turn, inhibits the ventilatory response to hypoxia (4,5,11). Thus for the usual measurement of the acute ventilatory response to...rest for 20 minutes. All of the ventilatory response tests were performed with the subject breathing through a respiratory valve (Model 2700, Hans...increase ventilation because the inhibition by hypocapnic alkalosis is prevented by adding CO2 to the inspired air to maintain C02 and pH at their
Coexposure to toluene and p-xylene in man: central nervous functions.
Olson, B A; Gamberale, F; Iregren, A
1985-01-01
Sixteen men were studied in an exposure chamber to assess the effect of four hours' exposure to toluene (3.25 mmol/m3), xylene (2.84 mmol/m3), a mixture of toluene and xylene (2.20 + 0.94 mmol/m3), and a control condition. With the aid of microcomputers, subjects performed tests of simple reaction time, short term memory, and choice reaction time immediately after entering the chamber, after two, and after four hours' exposure. The results indicate that the performance on the tests was unaffected by exposure. In the light of this result the risk of an acute effect on central nervous functions after exposure for four hours at concentrations that do not exceed the Swedish threshold limit values was considered to be minimal. PMID:3970870
Encephalopathy Associated with Influenza B in a Healthy Young Man.
Shimamoto, Masaki; Okada, Satoshi; Terashima, Takeshi
2017-01-01
A 19-year-old man presented with a fever, convulsions, and loss of consciousness at our hospital. The patient had a Glasgow Coma Scale score of 12. Influenza B virus infection was diagnosed using the rapid test kit, and an eight-fold increase in the serum levels of anti-influenza B virus antibody was confirmed using the complement fixation test. Brain magnetic resonance imaging showed multifocal high-signal lesions, and an electroencephalogram showed diffuse slowing of the background activity, indicating acute encephalopathy. After treatment with peramivir and methylprednisolone for 3 days, the patient was discharged without any neurological impairment. This was a case of influenza B infection associated with acute encephalopathy in a healthy young man.
NASA Technical Reports Server (NTRS)
Reaves, Will F.; Hoberecht, Mark A.
2003-01-01
The Fuel Cell has been used for manned space flight since the Gemini program. Its power output and water production capability over long durations for the mass and volume are critical for manned space-flight requirements. The alkaline fuel cell used on the Shuttle, while very reliable and capable for it s application, has operational sensitivities, limited life, and an expensive recycle cost. The PEM fuel cell offers many potential improvements in those areas. NASA Glenn Research Center is currently leading a PEM fuel cell development and test program intended to move the technology closer to the point required for manned space-flight consideration. This paper will address the advantages of PEM fuel cell technology and its potential for future space flight as compared to existing alkaline fuel cells. It will also cover the technical hurdles that must be overcome. In addition, a description of the NASA PEM fuel cell development program will be presented, and the current status of this effort discussed. The effort is a combination of stack and ancillary component hardware development, culminating in breadboard and engineering model unit assembly and test. Finally, a detailed roadmap for proceeding fiom engineering model hardware to qualification and flight hardware will be proposed. Innovative test engineering and potential payload manifesting may be required to actually validate/certify a PEM fuel cell for manned space flight.
The Role of the Nuclear Envelope Protein MAN1 in Mesenchymal Stem Cell Differentiation.
Bermeo, Sandra; Al-Saedi, Ahmed; Kassem, Moustapha; Vidal, Christopher; Duque, Gustavo
2017-12-01
Mutations in MAN1, a protein of the nuclear envelope, cause bone phenotypes characterized by hyperostosis. The mechanism of this pro-osteogenic phenotype remains unknown. We increased and decreased MAN1 expression in mesenchymal stem cells (MSC) upon which standard osteogenic and adipogenic differentiation were performed. MAN1 knockdown increased osteogenesis and mineralization. In contrast, osteogenesis remained stable upon MAN1 overexpression. Regarding a mechanism, we found that low levels of MAN1 facilitated the nuclear accumulation of regulatory smads and smads-related complexes, with a concurrently high expression of nuclear β-Catenin. In addition, we found adipogenesis to be decreased in both conditions, although predominantly affected by MAN1 overexpression. Finally, lamin A, a protein of the nuclear envelope that regulates MSC differentiation, was unaffected by changes in MAN1. In conclusion, our studies demonstrated that lower levels of MAN1 in differentiating MSC are associated with higher osteogenesis and lower adipogenesis. High levels of MAN1 only affected adipogenesis. These effects could have an important role in the understanding of the role of the proteins of the nuclear envelope in bone formation. J. Cell. Biochem. 118: 4425-4435, 2017. © 2017 Wiley Periodicals, Inc. © 2017 Wiley Periodicals, Inc.
Shivane, Aditya; Pearce, Amy; Khatib, Nadia; Smith, Mark E F
2018-06-01
We report a case of EBV+ and HHV-8+ multicentric Castleman disease with plasmablastic aggregates in an HIV-positive individual. A 41-year-old man presented in early 2015 with fevers, sweats, weight loss, intractable itching, and on subsequent testing was found to be HIV positive. Investigations showed cervical lymphadenopathy and splenomegaly. He was treated for HIV and his symptoms resolved. His symptoms recurred in January 2016, and a provisional diagnosis of multicentric Castleman disease was entertained. The HHV-8 (human herpesvirus-8) and EBV (Epstein-Barr virus) viral load was elevated. A left supraclavicular lymph node core biopsy was performed, which showed features of multicentric Castleman disease with plasmablastic aggregates that are EBV (EBER) and HHV-8 positive. He responded well to rituximab treatment and remains well with no symptoms at recent follow-up.
NASA Technical Reports Server (NTRS)
Rom, F. E.
1969-01-01
Recent developments in the fields of gas core hydrodynamics, heat transfer, and neutronics indicate that gas core nuclear rockets may be feasible from the point of view of basic principles. Based on performance predictions using these results, mission analyses indicate that gas core nuclear rockets may have the potential for reducing the initial weight in orbit of manned interplanetary vehicles by a factor of 5 when compared to the best chemical rocket systems. In addition, there is a potential for reducing total trip times from 450 to 500 days for chemical systems to 250 to 300 days for gas core systems. The possibility of demonstrating the feasibility of gas core nuclear rocket engines by means of a logical series of experiments of increasing difficulty that ends with ground tests of full scale gas core reactors is considered.
A middle man approach to knowledge acquisition in expert systems
NASA Technical Reports Server (NTRS)
Jordan, Janice A.; Lin, Min-Jin; Mayer, Richard J.; Sterle, Mark E.
1990-01-01
The Weed Control Advisor (WCA) is a robust expert system that has been successfully implemented on an IBM AT class microcomputer in CLIPS. The goal of the WCA was to demonstrate the feasibility of providing an economical, efficient, user friendly system through which Texas rice producers could obtain expert level knowledge regarding herbicide application for weed control. During the development phase of the WCA, an improved knowledge acquisition method which we call the Middle Man Approach (MMA) was applied to facilitate the communication process between the domain experts and the knowledge engineer. The MMA served to circumvent the problems associated with the more traditional forms of knowledge acquisition by placing the Middle Man, a semi-expert in the problem domain with some computer expertise, at the site of system development. The middle man was able to contribute to system development in two major ways. First, the Middle Man had experience working in rice production and could assume many of the responsibilities normally performed by the domain experts such as explaining the background of the problem domain and determining the important relations. Second, the Middle Man was familiar with computers and worked closely with the system developers to update the rules after the domain experts reviewed the prototype, contribute to the help menus and explanation portions of the expert system, conduct the testing that is required to insure that the expert system gives the expected results answer questions in a timely way, help the knowledge engineer structure the domain knowledge into a useable form, and provide insight into the end user's profile which helped in the development of the simple user friendly interface. The final results were not only that both time expended and costs were greatly reduced by using the MMA, but the quality of the system was improved. This papa will introduce the WCA system and then discuss traditional knowledge acquisition along with some of the problems often associated with it, the MMA methodology, and its application to the WCA development.
Lung, Jrhau; Lin, Yu-Ching; Hung, Ming-Szu; Jiang, Yuan Yuan; Lee, Kuan-Der; Lin, Paul Yann; Tsai, Ying Huang
2016-04-01
ALK fusion gene is an oncogenic driver in lung cancer with low prevalence, which can be ameliorated by crizotinib. Currently, ALK fusion gene can be diagnosed by fluorescence in situ hybridization (FISH) and immunohistochemistry (IHC), but inconstistnt results between the two methods are encountered regularly. To make the ALK fusion gene screening more efficient and to provide a simple solution to clarify the discrepancy between FISH and IHC results, a sensitive TaqMan-based reverse transcription quantitative polymerase chain reaction (RT-qPCR) assay was established. The 3-plex TaqMan-based RT-qPCR assay was established and performed on 102 archived formalin-fixed, paraffin-embedded (FFPE) NSCLC samples to detect ALK rearrangement and overexpression. Break-apart FISH and automatic immunohistochemistry based ALK assays were performed side by side using tissue microarray. The RT-qPCR was performed successfully for 80 samples and 10 of them showed positive signals. Three out of the 10 qPCR positive cases were further confirmed by FISH and IHC test. Two others were IHC positive and FISH negative, and expressed full-length ALK transcript. The rest were neither FISH nor IHC positive and their ALK expression level was significantly lower than those FISH or IHC positive cases. Our RT-qPCR assay demonstrates that the capability and reliability of ALK detection is comparable to FISH and IHC, but it is more effective at discriminating ALK rearrangement from overexpression. The RT-qPCR assay easily clarifies the discrepancy between FISH and IHC, and can be incorporated into routine ALK screening for lung cancer. Copyright © 2016 Elsevier Ireland Ltd. All rights reserved.
Dexamethasone suppression test
DST; ACTH suppression test; Cortisol suppression test ... During this test, you will receive dexamethasone. This is a strong man-made (synthetic) glucocorticoid medicine. Afterward, your blood is drawn ...
NASA Technical Reports Server (NTRS)
Mccllough, J. R.; Sharpe, A.; Doetsch, K. H.
1980-01-01
The SIMFAC has played a vital role in the design, development, and performance verification of the shuttle remote manipulator system (SRMS) to be installed in the space shuttle orbiter. The facility provides for realistic man-in-the-loop operation of the SRMS by an operator in the operator complex, a flightlike crew station patterned after the orbiter aft flight deck with all necessary man machine interface elements, including SRMS displays and controls and simulated out-of-the-window and CCTV scenes. The characteristics of the manipulator system, including arm and joint servo dynamics and control algorithms, are simulated by a comprehensive mathematical model within the simulation subsystem of the facility. Major studies carried out using SIMFAC include: SRMS parameter sensitivity evaluations; the development, evaluation, and verification of operating procedures; and malfunction simulation and analysis of malfunction performance. Among the most important and comprehensive man-in-the-loop simulations carried out to date on SIMFAC are those which support SRMS performance verification and certification when the SRMS is part of the integrated orbiter-manipulator system.
CaveMan Enterprise version 1.0 Software Validation and Verification.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Hart, David
The U.S. Department of Energy Strategic Petroleum Reserve stores crude oil in caverns solution-mined in salt domes along the Gulf Coast of Louisiana and Texas. The CaveMan software program has been used since the late 1990s as one tool to analyze pressure mea- surements monitored at each cavern. The purpose of this monitoring is to catch potential cavern integrity issues as soon as possible. The CaveMan software was written in Microsoft Visual Basic, and embedded in a Microsoft Excel workbook; this method of running the CaveMan software is no longer sustainable. As such, a new version called CaveMan Enter- prisemore » has been developed. CaveMan Enterprise version 1.0 does not have any changes to the CaveMan numerical models. CaveMan Enterprise represents, instead, a change from desktop-managed work- books to an enterprise framework, moving data management into coordinated databases and porting the numerical modeling codes into the Python programming language. This document provides a report of the code validation and verification testing.« less
NASA Technical Reports Server (NTRS)
Ewing, D. E.
1972-01-01
A modular approach for assessing the affects of radiation environments on man in operational systems has been developed. The feasibility of the model has been proved and the practicality has been assessed. It has been applied to one operational system to date and information obtained has been submitted to systems analysts and mission planners for the assessment of man's vulnerability and impact on systems survivability. In addition, the model has been developed so that the radiobiological data can be input to a sophisticated man-machine interface model to properly relate the radiobiological stress with other mission stresses including the effects of a degraded system.
NASA Astrophysics Data System (ADS)
Zhou, Qianxiang; Liu, Zhongqi
With the development of manned space technology, space rendezvous and docking (RVD) technology will play a more and more important role. The astronauts’ participation in a final close period of man-machine combination control is an important way of RVD technology. Spacecraft RVD control involves control problem of a total of 12 degrees of freedom (location) and attitude which it relative to the inertial space the orbit. Therefore, in order to reduce the astronauts’ operation load and reduce the security requirements to the ground station and achieve an optimal performance of the whole man-machine system, it is need to study how to design the number of control parameters of astronaut or aircraft automatic control system. In this study, with the laboratory conditions on the ground, a method was put forward to develop an experimental system in which the performance evaluation of spaceship RVD integration control by man and machine could be completed. After the RVD precision requirements were determined, 26 male volunteers aged 20-40 took part in the performance evaluation experiments. The RVD integration control success rates and total thruster ignition time were chosen as evaluation indices. Results show that if less than three RVD parameters control tasks were finished by subject and the rest of parameters control task completed by automation, the RVD success rate would be larger than eighty-eight percent and the fuel consumption would be optimized. In addition, there were two subjects who finished the whole six RVD parameters control tasks by enough train. In conclusion, if the astronauts' role should be integrated into the RVD control, it was suitable for them to finish the heading, pitch and roll control in order to assure the man-machine system high performance. If astronauts were needed to finish all parameter control, two points should be taken into consideration, one was enough fuel and another was enough long operation time.
NASA Technical Reports Server (NTRS)
Dinges, David F.
1999-01-01
This project is concerned with identifying ways to prevent neurobehavioral and physical deterioration due to inadequate sleep in astronauts during long-duration manned space flight. The performance capability of astronauts during extended-duration space flight depends heavily on achieving recovery through adequate sleep. Even with appropriate circadian alignment, sleep loss can erode fundamental elements of human performance capability including vigilance, cognitive speed and accuracy, working memory, reaction time, and physiological alertness. Adequate sleep is essential during manned space flight not only to ensure high levels of safe and effective human performance, but also as a basic regulatory biology critical to healthy human functioning. There is now extensive objective evidence that astronaut sleep is frequently restricted in space flight to averages between 4 hr and 6.5 hr/day. Chronic sleep restriction during manned space flight can occur in response to endogenous disturbances of sleep (motion sickness, stress, circadian rhythms), environmental disruptions of sleep (noise, temperature, light), and curtailment of sleep due to the work demands and other activities that accompany extended space flight operations. The mechanism through which this risk emerges is the development of cumulative homeostatic pressure for sleep across consecutive days of inadequate sleep. Research has shown that the physiological sleepiness and performance deficits engendered by sleep debt can progressively worsen (i.e., accumulate) over consecutive days of sleep restriction, and that sleep limited to levels commonly experienced by astronauts (i.e., 4 - 6 hr per night) for as little as 1 week, can result in increased lapses of attention, degradation of response times, deficits in complex problem solving, reduced learning, mood disturbance, disruption of essential neuroendocrine, metabolic, and neuroimmune responses, and in some vulnerable persons, the emergence of uncontrolled sleep attacks. The prevention of cumulative performance deficits and neuroendocrine disruption from sleep restriction during extended duration space flight involves finding the most effective ways to obtain sleep in order to maintain the high-level cognitive and physical performance functions required for manned space flight. There is currently a critical deficiency in knowledge of the effects of how variations in sleep duration and timing relate to the most efficient return of performance per unit time invested in sleep during long-duration missions, and how the nature of sleep physiology (i.e., sleep stages, sleep electroencephalographic [EEG] power spectral analyses) change as a function of sleep restriction and performance degradation. The primary aim of this project is to meet these critical deficiencies through utilization of a response surface experimental paradigm, testing in a dose-response manner, varying combinations of sleep duration and timing, for the purpose of establishing how to most effectively limit the cumulative adverse effects on human performance and physiology of chronic sleep restriction in space operations.
The Scent of the Future: Manned Space Travel and the Soviet Union.
1981-06-01
AND ECONOMIC APPLICATIONS 56 GREENHOUSES , BOOSTERS, AND SPACE PLANES: SOVIET SPACE-RELATED RESEARCH AND DEVELOPMENT 72 R.U.R. REVISITED: MANNED VERSUS... greenhouse that was part of their 12-square-meter closed environment.9 6 The successful conclusion of this test demonstrated the feasibility of a manned...will probably be timed to coincide with the XXVI Party Congress which convenes in February 1981. 71 GREENHOUSES , BOOSTERS, AND SPACE PLANES: SOVIET
NASA Technical Reports Server (NTRS)
Malone, T. B.
1972-01-01
Requirements were determined analytically for the man machine interface for a teleoperator system performing on-orbit satellite retrieval and servicing. Requirements are basically of two types; mission/system requirements, and design requirements or design criteria. Two types of teleoperator systems were considered: a free flying vehicle, and a shuttle attached manipulator. No attempt was made to evaluate the relative effectiveness or efficiency of the two system concepts. The methodology used entailed an application of the Essex Man-Systems analysis technique as well as a complete familiarization with relevant work being performed at government agencies and by private industry.
Manned/Unmanned Common Architecture Program (MCAP) net centric flight tests
NASA Astrophysics Data System (ADS)
Johnson, Dale
2009-04-01
Properly architected avionics systems can reduce the costs of periodic functional improvements, maintenance, and obsolescence. With this in mind, the U.S. Army Aviation Applied Technology Directorate (AATD) initiated the Manned/Unmanned Common Architecture Program (MCAP) in 2003 to develop an affordable, high-performance embedded mission processing architecture for potential application to multiple aviation platforms. MCAP analyzed Army helicopter and unmanned air vehicle (UAV) missions, identified supporting subsystems, surveyed advanced hardware and software technologies, and defined computational infrastructure technical requirements. The project selected a set of modular open systems standards and market-driven commercial-off-theshelf (COTS) electronics and software, and, developed experimental mission processors, network architectures, and software infrastructures supporting the integration of new capabilities, interoperability, and life cycle cost reductions. MCAP integrated the new mission processing architecture into an AH-64D Apache Longbow and participated in Future Combat Systems (FCS) network-centric operations field experiments in 2006 and 2007 at White Sands Missile Range (WSMR), New Mexico and at the Nevada Test and Training Range (NTTR) in 2008. The MCAP Apache also participated in PM C4ISR On-the-Move (OTM) Capstone Experiments 2007 (E07) and 2008 (E08) at Ft. Dix, NJ and conducted Mesa, Arizona local area flight tests in December 2005, February 2006, and June 2008.
NASA Technical Reports Server (NTRS)
Aten, Laurie A.; Crump, William J.; Sauer, Richard L.
1992-01-01
Among the challenges of designing and constructing Space Station Freedom is the development of the water system. A review of past efforts in reclaiming waste water in enclosed environments reveals that there are many gaps in the biomedical understanding of this process. Some of the key uncertainties of human interaction with a closed water system include determining potential contaminants and establishing safe levels of multiple compounds in the enclosed system of Space Station. Another uncertainty is the microbial constituency of such a system and what impact it could have on crew health and performance. The use of iodine as the passive biocide may have both an indirect and direct impact on the crew. In this paper the initial results of the Water Recovery Test are reviewed from a biomedical perspective, revealing areas where more information is needed to develop the ECLSS water system. By including the approach of 'man as a subsystem', consideration is given to how man interacts with the total water system. Taking this systems approach to providing the crew with a safe source of water gives useful insight into the most efficient design and utilization of closed system testbeds.
NASA Technical Reports Server (NTRS)
Jack, Devin P.; Hoffler, Keith D.; Johnson, Sally C.
2014-01-01
A need exists to safely integrate Unmanned Aircraft Systems (UAS) into the National Airspace System. Replacing manned aircraft's see-and-avoid capability in the absence of an onboard pilot is one of the key challenges associated with safe integration. Sense-and-avoid (SAA) systems will have to achieve yet-to-be-determined required separation distances for a wide range of encounters. They will also need to account for the maneuver performance of the UAS they are paired with. The work described in this paper is aimed at developing an understanding of the trade space between UAS maneuver performance and SAA system performance requirements. An assessment of current manned and unmanned aircraft performance was used to establish potential UAS performance test matrix bounds. Then, nearterm UAS integration work was used to narrow down the scope. A simulator was developed with sufficient fidelity to assess SAA system performance requirements for a wide range of encounters. The simulator generates closest-point-of-approach (CPA) data from the wide range of UAS performance models maneuvering against a single intruder with various encounter geometries. The simulator is described herein and has both a graphical user interface and batch interface to support detailed analysis of individual UAS encounters and macro analysis of a very large set of UAS and encounter models, respectively. Results from the simulator using approximate performance data from a well-known manned aircraft is presented to provide insight into the problem and as verification and validation of the simulator. Analysis of climb, descent, and level turn maneuvers to avoid a collision is presented. Noting the diversity of backgrounds in the UAS community, a description of the UAS aerodynamic and propulsive design and performance parameters is included. Initial attempts to model the results made it clear that developing maneuver performance groups is required. Discussion of the performance groups developed and how to know in which group an aircraft belongs for a given flight condition and encounter is included. The groups are specific to airplane, flight condition, and encounter, rather than airplane-only specific. Results and methodology for developing UAS maneuver performance requirements are presented for each maneuver as well. Results for the vertical maneuver indicate that a minimum specific excess power value can assure a minimum CPA for a given time-to-go prediction. However, smaller values of specific excess power may achieve or exceed the same CPA if the UAS has sufficient speed to trade for altitude. Level turn results are less impacted by specific excess power and are presented as a function of turn rate. The effect of altitude is also discussed for the turns. Next steps and future work are discussed. Future studies will lead to better quantification of the preliminary results and cover the remainder of the proposed test matrix. It is anticipated that this will be done in conjunction with RTCA SC-228 over the next few months.
Resolution of fish allergy: a case report.
Solensky, Roland
2003-10-01
Fish allergy is one of the most common food allergies, and it is believed to be lifelong. There are no published reports, to my knowledge, of resolution of fish allergy. To report a case of resolution of IgE-mediated fish allergy. The patient was a 68-year-old man with a history of fish-induced anaphylaxis who had previously undergone prick-puncture skin testing to several fish species. Additional skin testing was performed in October 2002. Subsequently, he underwent an open challenge with halibut. The patient's previous skin tests showed him to have strongly positive reactions to several fish species. However, testing performed in October 2002 produced negative results to a number of fish species. In addition, he tolerated an open challenge with halibut. In the ensuing 8 months, he has regularly ingested salmon, cod, and halibut without experiencing any allergic reactions. This case illustrates that fish allergy is not invariably lifelong. Hence, allergists should consider reevaluating the allergy status of adults with a history of fish hypersensitivity.
Flight test experience and controlled impact of a large, four-engine, remotely piloted airplane
NASA Technical Reports Server (NTRS)
Kempel, R. W.; Horton, T. W.
1985-01-01
A controlled impact demonstration (CID) program using a large, four engine, remotely piloted transport airplane was conducted. Closed loop primary flight control was performed from a ground based cockpit and digital computer in conjunction with an up/down telemetry link. Uplink commands were received aboard the airplane and transferred through uplink interface systems to a highly modified Bendix PB-20D autopilot. Both proportional and discrete commands were generated by the ground pilot. Prior to flight tests, extensive simulation was conducted during the development of ground based digital control laws. The control laws included primary control, secondary control, and racetrack and final approach guidance. Extensive ground checks were performed on all remotely piloted systems. However, manned flight tests were the primary method of verification and validation of control law concepts developed from simulation. The design, development, and flight testing of control laws and the systems required to accomplish the remotely piloted mission are discussed.
Casaburi, R; Stringer, W W; Singer, E
1995-01-01
1. The mechanisms underlying the exercise hyperpnoea have been difficult to define. Recently it has been suggested that exercise ventilation (VE) changes in proportion to changes in arterial potassium concentration ([K+]a). Similar VE and [K+]a time courses following work rate changes have been cited as supporting evidence. This study compared [K+]a and VE dynamics during moderate exercise in man. 2. We observed VE and gas exchange responses in five healthy men to sinusoidal work rate variation between 25 and approximately 105 W. Tests of approximately 30 min duration were performed at sinusoidal periods of 9, 6 and 3 min and in the steady state. In each test, during two or three sine periods, arterial blood was sampled (24 per test) and analysed for [K+] and blood gases. Response amplitude and phase (relative to work rate) were determined for each variable. 3. [K+]a fluctuated in response to sinusoidal work rate forcing with mean-to-peak amplitude averaging 0.15 mmol 1(-1). However, among tests, VE amplitude and phase were not highly correlated with [K+]a (r = 0.36 and 0.67, respectively). Further, average [K+]a amplitude in the 9 and 6 min sinusoidal studies tended to exceed the steady-state amplitude, while average VE amplitude fell progressively with increasing forcing frequency. The dissimilar dynamics of [K+]a and VE seem inconsistent with a major role for [K+]a as a proportional controller of ventilation during non-steady state moderate exercise in man. 4. Among tests, VE and CO2 output (VCO2) amplitude and phase were closely correlated (r = 0.87 and 0.94, respectively). Further, arterial CO2 pressure (Pa,CO2) and arterial pH(pHa) did not fluctuate significantly in ten of twenty and thirteen of twenty studies, respectively. In tests where sinusoidal fluctuation was detected, amplitude averaged 1.1 mmHg and 0.008 units, respectively. Thus VE demonstrated a close dynamic coupling to CO2 output, with consequent tight regulation of Pa,CO2 and pHa. PMID:7666376
Analytical definition and proposed concept for the manned infrastructure of a lunar outpost
NASA Astrophysics Data System (ADS)
Clément, G.; Braak, L.; Arénalès, O.
A recent study made by ESA has reviewed the scientific investigations to be only, or best, performed on the Moon (Return to the Moon, ESA SP-1150, June 1992), and has identified the need for a manned lunar outpost to provide support to field geologists in sampling and in-situ observations of the lunar surface, and to allow the refurbishments of surface stations and rovers. Planning and development for a manned outpost on the Moon requires an in-depth understanding and analysis of the functions this outpost is expected to perform. We therefore analyzed the impact of the proposed scientific investigations on the design of a manned lunar outpost. The specific questions raised in our study were: What are the medical, physiological and psychological risks for a crew to stay and to work on the Moon? What transit and lunar surface infrastructures (habitats and vehicles) are needed to minimize those risks?
Infrared hyperspectral imaging sensor for gas detection
NASA Astrophysics Data System (ADS)
Hinnrichs, Michele
2000-11-01
A small light weight man portable imaging spectrometer has many applications; gas leak detection, flare analysis, threat warning, chemical agent detection, just to name a few. With support from the US Air Force and Navy, Pacific Advanced Technology has developed a small man portable hyperspectral imaging sensor with an embedded DSP processor for real time processing that is capable of remotely imaging various targets such as gas plums, flames and camouflaged targets. Based upon their spectral signature the species and concentration of gases can be determined. This system has been field tested at numerous places including White Mountain, CA, Edwards AFB, and Vandenberg AFB. Recently evaluation of the system for gas detection has been performed. This paper presents these results. The system uses a conventional infrared camera fitted with a diffractive optic that images as well as disperses the incident radiation to form spectral images that are collected in band sequential mode. Because the diffractive optic performs both imaging and spectral filtering, the lens system consists of only a single element that is small, light weight and robust, thus allowing man portability. The number of spectral bands are programmable such that only those bands of interest need to be collected. The system is entirely passive, therefore, easily used in a covert operation. Currently Pacific Advanced Technology is working on the next generation of this camera system that will have both an embedded processor as well as an embedded digital signal processor in a small hand held camera configuration. This will allow the implementation of signal and image processing algorithms for gas detection and identification in real time. This paper presents field test data on gas detection and identification as well as discuss the signal and image processing used to enhance the gas visibility. Flow rates as low as 0.01 cubic feet per minute have been imaged with this system.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Protat, Alain; Young, S.
The objective of this IOP was to evaluate the performances of the new Leosphere R-MAN 510 lidar procured by the Australian Bureau of Meteorology, by testing it against the MPL and Raman lidars at the Darwin ARM site. This lidar is an eye-safe (355 nm), turn-key mini Raman lidar, which allows for the detection of aerosols and cloud properties, and the retrieval of particulate extinction profiles. To do so, the R-MAN 510 lidar has been operated at the Darwin ARM site, next to the MPL, Raman lidar, and Vaisala ceilometer for three months (from 20 January 2013 to 20 Aprilmore » 2013) in order to collect a good sample for statistical comparisons. The comparisons with the Raman lidar were not performed, since the Raman lidar attenuated backscatter and depolarization ratio product was not available. A new product has just been delivered to the ARM archive as a value-added product, hence this study will continue. Nevertheless we have developed software to match the different space and time resolutions of the other lidars and project the data onto a common grid to permit detailed comparison of the instruments’ performance and an enhanced analysis of clouds and aerosols through the use of composite data products, like the ratios of attenuated backscatters, attenuated scattering ratios and depolarization ratios. Comparisons between the MPL and R-MAN510 lidar data exhibit large differences in total attenuated backscatter at 355 and 532 nm, attenuated scattering ratios, and aerosol volume depolarization ratios. Differences in attenuated backscatter result mainly from the different relative contributions of scattering from molecules and particles at the different wavelengths, but there are some intriguing differences that will require further investigations. The differences in volume depolarization ratios are due to the much larger contribution of molecular returns to the volume depolarization ratio (5 times larger at 355 nm than at 532 nm). The R-MAN510 lidar is also found to be much less sensitive to daylight solar background illumination, which is greater at the visible wavelength than in the UV.« less
HIV Viral Load: MedlinePlus Lab Test Information
... and blood. (It can also be transmitted from mother to child during birth and through breast milk.) You may be at higher risk of infection if you: Are a man that has had sex with another man Have had sex with an ...
Electrochemical carbon dioxide concentrator subsystem math model. [for manned space station
NASA Technical Reports Server (NTRS)
Marshall, R. D.; Carlson, J. N.; Schubert, F. H.
1974-01-01
A steady state computer simulation model has been developed to describe the performance of a total six man, self-contained electrochemical carbon dioxide concentrator subsystem built for the space station prototype. The math model combines expressions describing the performance of the electrochemical depolarized carbon dioxide concentrator cells and modules previously developed with expressions describing the performance of the other major CS-6 components. The model is capable of accurately predicting CS-6 performance over EDC operating ranges and the computer simulation results agree with experimental data obtained over the prediction range.
ERIC Educational Resources Information Center
Dade County Public Schools, Miami, FL.
Performance objectives are stated for each of the five secondary school units included in this package of instructional guides prepared for the Dade County Florida Quinmester Program. All five units are concerned with aspects of physiology; three require no prerequisite study of biology ("Introduction to the Human Body,""Man and…
Low Temperature Life-Cycle Testing of a Lithium-Ion Battery for Low-Earth-Orbiting Spacecraft
NASA Technical Reports Server (NTRS)
Reid, Concha
2006-01-01
A flight-qualified, lithium-ion (Li-ion) battery developed for the Mars Surveyor Program 2001 Landeris undergoing life-testing at low temperature under a low-Earth-orbit (LEO) profile to assess its capability to provide long term energy storage for aerospace missions. NASA has embarked upon an ambitious course to return humans to the moon by 2015-2020 in preparation for robotic and human exploration of Mars and robotic exploration of the moons of outer planets. Li-ion batteries are excellent candidates to provide power and energy storage for multiple aspects of these missions due to their high specific energy, high energy density, and excellent low temperature performance. Laboratory testing of Li-ion technology is necessary in order to assess lifetime, characterize multi-cell battery-level performance under aerospace conditions, and to gauge safety aspects of the technology. Life-cycle testing provides an opportunity to examine battery-level performance and the dynamics of individual cells in the stack over the entire life of the battery. Data generated through this testing will be critical to establish confidence in the technology for its widespread use in manned and unmanned missions.
Evaluation of the Abbott RealTime HCV assay for quantitative detection of hepatitis C virus RNA.
Michelin, Birgit D A; Muller, Zsofia; Stelzl, Evelyn; Marth, Egon; Kessler, Harald H
2007-02-01
The Abbott RealTime HCV assay for quantitative detection of HCV RNA has recently been introduced. In this study, the performance of the Abbott RealTime HCV assay was evaluated and compared to the COBAS AmpliPrep/COBAS TaqMan HCV test. Accuracy, linearity, interassay and intra-assay variations were determined, and a total of 243 routine clinical samples were investigated. When accuracy of the new assay was tested, the majority of results were found to be within +/-0.5 log(10) unit of the results obtained by reference laboratories. Determination of linearity resulted in a quasilinear curve up to 1.0 x 10(6)IU/ml. The interassay variation ranged from 15% to 32%, and the intra-assay variation ranged from 5% to 8%. When clinical samples were tested by the Abbott RealTime HCV assay and the results were compared with those obtained by the COBAS AmpliPrep/COBAS TaqMan HCV test, the results for 93% of all samples with positive results by both tests were found to be within +/-1.0 log(10) unit. The viral loads for all patients measured by the Abbott and Roche assays showed a high correlation (R(2)=0.93); quantitative results obtained by the Abbott assay were found to be lower than those obtained by the Roche assay. The Abbott RealTime HCV assay proved to be suitable for use in the routine diagnostic laboratory. The time to results was similar for both of the assays.
Bartsch, H; Tomatis, L
1983-01-01
The qualitative relationship between carcinogenicity and mutagenicity (DNA-damaging activity), based on chemicals which are known to be or suspected of being carcinogenic to man and/or to experimental animals, is analyzed using 532 chemicals evaluated in Volumes 1-25 of the IARC Monographs on the Evaluation of the Carcinogenic Risk of Chemicals to Humans. About 40 compounds (industrial processes) were found to be either definitely or probably carcinogenic to man, and 130 chemicals have been adequately tested in rodents and most of them also in various short-term assays. For a comparison between the carcinogenicity of a chemical and its behavior in short-term tests, systems were selected that have a value for predicting carcinogenicity. These were divided into mutagenicity in (A) the S. typhimurium/microsome assay, (B) other submammalian systems and (C) cultured mammalian cells; (D) chromosomal abnormalities in mammalian cells; (E) DNA damage and repair; (F) cell transformation (or altered growth properties) in vitro. The following conclusions can be drawn. In the absence of studies in man, long-term animal tests are still today the only ones capable of providing evidence of the carcinogenic effect of a chemical. The development and application of an appropriate combination of short-term tests (despite current limitations) can significantly contribute to the prediction/confirmation of the carcinogenic effects of chemicals in animals/man. Confidence in positive tests results is increased when they are confirmed in multiple short-term tests using nonrepetitive end points and different activation systems. Assays to detect carcinogens which do not act via electrophiles (promoters) need to be developed. The results of a given short-term test should be interpreted in the context of other toxicological data. Increasing demand for quantitative carcinogenicity data requires further examination of whether or not there is a quantitative relationship between the potency of a carcinogen in experimental animals/man, and its genotoxic activity in short-term tests. At present, such a relationship is not sufficiently established for it to be used for the prediction of the carcinogenic potency of new compounds. PMID:6337827
Babady, N Esther; Germer, Jeffrey J; Yao, Joseph D C
2010-03-01
No significantly discordant results were observed between the Abbott RealTime HIV-1 assay and the COBAS AmpliPrep/COBAS TaqMan HIV-1 Test (CTM) among 1,190 unique clinical plasma specimens obtained from laboratories located in 40 states representing all nine U.S. geographic regions and previously yielding "target not detected" results by CTM.
Amos, D. Bernard; Bach, Fritz H.
1968-01-01
The evidence is reviewed that a single genetic system, the major histocompatibility locus in man, HL-A, determines most of the antigens measured by presently available leukocyte isoantisera, and also controls reactivity in one-way mixed leucocyte culture tests. Studies in 12 families are presented to support this conclusion. Some interesting exceptions to the general typing—MLC tests correlation are presented and discussed. PMID:5675436
NASA Technical Reports Server (NTRS)
Koch, L. Danielle; VanZante, Dale E.; Wernet, Mark P.; Podboy, Gary G.
2006-01-01
Quiet, high performance electronics cooling fans are needed for both commercial applications and future manned space exploration missions. Researchers at NASA Glenn focusing on aircraft engine noise, have long been familiar with the challenge of reducing fan noise without sacrificing aerodynamic performance. Is it possible to capitalize on the lessons-learned in aircraft engine noise reduction to identify inexpensive ways to improve the aerodynamic and acoustic performance of electronics cooling fans? Recent tests at NASA Glenn have begun to look for answers to this question. The overall aerodynamic and acoustic performance of a commercially available, spaceflight qualified 80 mm diameter axial flow fan has been measured using an automated plenum in accordance with ISO 10302 in the hemi-anechoic chamber of NASA Glenn s Acoustical Testing Laboratory. These measurements are complemented by detailed aerodynamic measurements of the inlet, exhaust, and rotor wake regions of the fan using Particle Image Velocimetry and hot-wire probes. A study of preliminary results yielded recommendations for system designers, fan manufacturers, and researchers.
Negassi, K; Closs, O; Harboe, M
1979-01-01
Cross-reactions between serum proteins and water soluble liver antigens of the nine-banded armadillo (Dasypus novemcinctus Linn.) and man were studied by crossed immunoelectrophoresis (CIE). Armadillo serum tested with rabbit antiserum against human serum proteins gave twelve components in CIE. Nine of these cross-reacting proteins were identified and showed partial identity with the corresponding human proteins. The electrophoretic mobility of alpha 2-macroglobulin and Gc-globulin differed in the two species. An ultrasonicate of normal armadillo liver gave twenty-eight anodic and eight cathodic components in CIE. By absorption experiments with armadillo serum, twenty of the former and seven of the latter were shown to be liver tissue components. A combination of CIE and crossed-line immunoelectrophoresis (CLIE) revealed the presence of twelve anodic and six cathodic liver tissue components cross-reacting with man. A cathodic armadillo liver antigen called (CALA-17) showed partial identity with that of man both in tandem and fused rocket immunoelectrophoresis. The implications of the findings are discussed in relation to the use of armadillo-grown M. leprae for skin testing and other purposes in man. Images FIG. 1 FIG. 3 FIG. 4 FIG. 5 PMID:93527
Lymphogranuloma venereum in an Italian MSM: concurrent pharyngeal and rectal infection.
Foschi, Claudio; Filippini, Andrea; D'Antuono, Antonietta; Compri, Monica; Macca, Francesca; Banzola, Nicoletta; Marangoni, Antonella
2014-07-01
An Italian HIV-positive man having sex with men (MSM) attended the STIs Outpatients Clinic of Sant'Orsola Hospital in Bologna complaining of anal pain and constipation. According to patient's sexual history and repertoires, NAAT testing for Chlamydia trachomatis (CT) and Neisseria gonorrhoeae (GC) was performed. Pharyngeal and anal swabs resulted positive for CT DNA detection and the following molecular genotyping identified a L2 serovar, coming to the final diagnosis of pharyngeal and rectal lymphogranuloma venereum (LGV) infection. After an antibiotic therapy with doxycycline 100 mg twice a day for 3 weeks, the patient completely recovered and the test of cure was negative for LGV infection.
Damage Tolerance Assessment Branch
NASA Technical Reports Server (NTRS)
Walker, James L.
2013-01-01
The Damage Tolerance Assessment Branch evaluates the ability of a structure to perform reliably throughout its service life in the presence of a defect, crack, or other form of damage. Such assessment is fundamental to the use of structural materials and requires an integral blend of materials engineering, fracture testing and analysis, and nondestructive evaluation. The vision of the Branch is to increase the safety of manned space flight by improving the fracture control and the associated nondestructive evaluation processes through development and application of standards, guidelines, advanced test and analytical methods. The Branch also strives to assist and solve non-aerospace related NDE and damage tolerance problems, providing consultation, prototyping and inspection services.
Cytomegalovirus retinitis in a patient with proliferative diabetes retinopathy.
Takayama, Kei; Ogawa, Manabu; Mochizuki, Manabu; Takeuchi, Masaru
2013-06-01
To report a case of cytomegalovirus (CMV) retinitis in an immunocompetent patient with proliferative diabetic retinopathy (PDR). Case report. A 69-year-old man presented with a 44-year history of diabetes mellitus and 4 years of PDR. Fundus of left eye could not be visualized because of vitreous hemorrhage. Laboratory tests indicated normal immunological status. Yellowish white retinal exudative lesion and whitening inside vascular arcades were observed during vitrectomy. Multiplex PCR using vitreous sample detected CMV DNA at 4.37 × 10(4) copies/mL. CMV retinitis was diagnosed. If atypical findings of PDR are observed, a multiplex PCR test should be performed for further investigation.
Aerospace Medicine and Biology: A continuing bibliography with indexes (supplement 259)
NASA Technical Reports Server (NTRS)
1984-01-01
A bibliography containing 476 documents introduced into the NASA scientific and technical information system in May 1984 is presented. The primary subject categories included are: life sciences, aerospace medicine, behavioral sciences, man/system technology, life support, and planetary biology. Topics extensively represented were space flight stress, man machine systems, weightlessness, human performance, mental performance, and spacecraft environments. Abstracts for each citation are given.
Harvey, John J; Chester, Stephanie; Burke, Stephen A; Ansbro, Marisela; Aden, Tricia; Gose, Remedios; Sciulli, Rebecca; Bai, Jing; DesJardin, Lucy; Benfer, Jeffrey L; Hall, Joshua; Smole, Sandra; Doan, Kimberly; Popowich, Michael D; St George, Kirsten; Quinlan, Tammy; Halse, Tanya A; Li, Zhen; Pérez-Osorio, Ailyn C; Glover, William A; Russell, Denny; Reisdorf, Erik; Whyte, Thomas; Whitaker, Brett; Hatcher, Cynthia; Srinivasan, Velusamy; Tatti, Kathleen; Tondella, Maria Lucia; Wang, Xin; Winchell, Jonas M; Mayer, Leonard W; Jernigan, Daniel; Mawle, Alison C
2016-02-01
In this study, a multicenter evaluation of the Life Technologies TaqMan(®) Array Card (TAC) with 21 custom viral and bacterial respiratory assays was performed on the Applied Biosystems ViiA™ 7 Real-Time PCR System. The goal of the study was to demonstrate the analytical performance of this platform when compared to identical individual pathogen specific laboratory developed tests (LDTs) designed at the Centers for Disease Control and Prevention (CDC), equivalent LDTs provided by state public health laboratories, or to three different commercial multi-respiratory panels. CDC and Association of Public Health Laboratories (APHL) LDTs had similar analytical sensitivities for viral pathogens, while several of the bacterial pathogen APHL LDTs demonstrated sensitivities one log higher than the corresponding CDC LDT. When compared to CDC LDTs, TAC assays were generally one to two logs less sensitive depending on the site performing the analysis. Finally, TAC assays were generally more sensitive than their counterparts in three different commercial multi-respiratory panels. TAC technology allows users to spot customized assays and design TAC layout, simplify assay setup, conserve specimen, dramatically reduce contamination potential, and as demonstrated in this study, analyze multiple samples in parallel with good reproducibility between instruments and operators. Copyright © 2015 Elsevier B.V. All rights reserved.
NASA Technical Reports Server (NTRS)
Gershzohn, Gary R.; Sirko, Robert J.; Zimmerman, K.; Jones, A. D.
1990-01-01
This task concerns the design, development, testing, and evaluation of a new proximity operations planning and flight guidance display and control system for manned space operations. A forecast, derivative manned maneuvering unit (MMU) was identified as a candidate for the application of a color, highway-in-the-sky display format for the presentation of flight guidance information. A silicon graphics 4D/20-based simulation is being developed to design and test display formats and operations concepts. The simulation includes the following: (1) real-time color graphics generation to provide realistic, dynamic flight guidance displays and control characteristics; (2) real-time graphics generation of spacecraft trajectories; (3) MMU flight dynamics and control characteristics; (4) control algorithms for rotational and translational hand controllers; (5) orbital mechanics effects for rendezvous and chase spacecraft; (6) inclusion of appropriate navigation aids; and (7) measurement of subject performance. The flight planning system under development provides for: (1) selection of appropriate operational modes, including minimum cost, optimum cost, minimum time, and specified ETA; (2) automatic calculation of rendezvous trajectories, en route times, and fuel requirements; (3) and provisions for manual override. Man/machine function allocations in planning and en route flight segments are being evaluated. Planning and en route data are presented on one screen composed of two windows: (1) a map display presenting a view perpendicular to the orbital plane, depicting flight planning trajectory and time data attitude display presenting attitude and course data for use en route; and (2) an attitude display presenting local vertical-local horizontal attitude data superimposed on a highway-in-the-sky or flight channel representation of the flight planned course. Both display formats are presented while the MMU is en route. In addition to these displays, several original display elements are being developed, including a 3DOF flight detector for attitude commanding, a different flight detector for translation commands, and a pictorial representation of velocity deviations.
1981-04-12
S81-33179 (12 April 1981) --- Though their STS-1 task has been performed, the two solid rocket boosters (SRB) still glow following their jettisoning from the space shuttle Columbia on its way to many firsts. Among the history recorded by the spacecraft is the marking of a mission in a reusable spacecraft. STS-1 is NASA's first manned mission since the Apollo-Soyuz Test Project in 1975. Inside the cabin of the climbing spacecraft are astronauts John W. Young and Robert L. Crippen. Photo credit: NASA
NASA Technical Reports Server (NTRS)
Brown, N. E.
1973-01-01
Parameters that require consideration by the planners and designers when planning for man to perform functions outside the vehicle are presented in terms of the impact the extravehicular crewmen and major EV equipment items have on the mission, vehicle, and payload. Summary data on man's performance capabilities in the weightless space environment are also provided. The performance data are based on orbital and transearth EVA from previous space flight programs and earthbound simulations, such as water immersion and zero-g aircraft.
One man electrochemical air revitalization system
NASA Technical Reports Server (NTRS)
Huddleston, J. C.; Aylward, J. R.
1975-01-01
An integrated water vapor electrolysis (WVE) hydrogen depolarized CO2 concentrator (HDC) system sized for one man support over a wide range of inlet air conditions was designed, fabricated, and tested. Data obtained during 110 days of testing verified that this system can provide the necessary oxygen, CO2 removal, and partial humidity control to support one man (without exceeding a cabin partial pressure of 3.0 mmHg for CO2 and while maintaining a 20% oxygen level), when operated at a WVE current of 50 amperes and an HDC current of 18 amperes. An evaluation to determine the physical properties of tetramethylammonium bicarbonate (TMAC) and hydroxide was made. This provides the necessary electrolyte information for designing an HDC cell using TMAC.
Infected Aneurysm after Endoscopic Submucosal Dissection.
Gen, Shiko; Usui, Ryuichi; Sasaki, Takaya; Nobe, Kanako; Takahashi, Aya; Okudaira, Keisuke; Ikeda, Naofumi
2016-01-01
A 79-year-old man on hemodialysis was hospitalized for further investigation. Early gastric cancer was diagnosed by gastrointestinal endoscopy and endoscopic submucosal dissection (ESD) was performed. Fever and abdominal pain thereafter developed, and a severe inflammatory response was observed on a blood test. Contrast computed tomography (CT) showed ulcer-like projections and soft tissue surrounding the aorta, from the celiac to left renal artery. An infected aneurysm was diagnosed. Although infected aneurysms developing after laparoscopic cholecystectomy or biopsy of contiguous esophageal duplication cyst have been reported, those developing after ESD have not. When fever and abdominal pain develop after ESD, an infected aneurysm should be considered and contrast CT performed.
Rapid diagnosis of sepsis with TaqMan-Based multiplex real-time PCR.
Liu, Chang-Feng; Shi, Xin-Ping; Chen, Yun; Jin, Ye; Zhang, Bing
2018-02-01
The survival rate of septic patients mainly depends on a rapid and reliable diagnosis. A rapid, broad range, specific and sensitive quantitative diagnostic test is the urgent need. Thus, we developed a TaqMan-Based Multiplex real-time PCR assays to identify bloodstream pathogens within a few hours. Primers and TaqMan probes were designed to be complementary to conserved regions in the 16S rDNA gene of different kinds of bacteria. To evaluate accurately, sensitively, and specifically, the known bacteria samples (Standard strains, whole blood samples) are determined by TaqMan-Based Multiplex real-time PCR. In addition, 30 blood samples taken from patients with clinical symptoms of sepsis were tested by TaqMan-Based Multiplex real-time PCR and blood culture. The mean frequency of positive for Multiplex real-time PCR was 96% at a concentration of 100 CFU/mL, and it was 100% at a concentration greater than 1000 CFU/mL. All the known blood samples and Standard strains were detected positively by TaqMan-Based Multiplex PCR, no PCR products were detected when DNAs from other bacterium were used in the multiplex assay. Among the 30 patients with clinical symptoms of sepsis, 18 patients were confirmed positive by Multiplex real-time PCR and seven patients were confirmed positive by blood culture. TaqMan-Based Multiplex real-time PCR assay with highly sensitivity, specificity and broad detection range, is a rapid and accurate method in the detection of bacterial pathogens of sepsis and should have a promising usage in the diagnosis of sepsis. © 2017 Wiley Periodicals, Inc.
Offgassing Characterization of the Columbus Laboratory Module
NASA Technical Reports Server (NTRS)
Rampini, riccardo; Lobascio, Cesare; Perry, Jay L.; Hinderer, Stephan
2005-01-01
Trace gaseous contamination in the cabin environment is a major concern for manned spacecraft, especially those designed for long duration missions, such as the International Space Station (ISS). During the design phase, predicting the European-built Columbus laboratory module s contribution to the ISS s overall trace contaminant load relied on "trace gas budgeting" based on material level and assembled article tests data. In support of the Qualification Review, a final offgassing test has been performed on the complete Columbus module to gain cumulative system offgassing data. Comparison between the results of the predicted offgassing load based on the budgeted material/assembled article-level offgassing rates and the module-level offgassing test is presented. The Columbus module offgassing test results are also compared to results from similar tests conducted for Node 1, U.S. Laboratory, and Airlock modules.
NASA Technical Reports Server (NTRS)
Smith, R. A.
1979-01-01
Operational and physical requirements were investigated for a low-light-level viewing device to be used as a window-mounted optical sight for crew use in the pointing, navigating, stationkeeping, and docking of space vehicles to support space station operations and the assembly of large structures in space. A suitable prototype, obtained from a commercial vendor, was subjected to limited tests to determine the potential effectiveness of a proximity optical device in spacecraft operations. The constructional features of the device are discussed as well as concepts for its use. Tests results show that a proximity optical device is capable of performing low-light-level viewing services and will enhance manned spacecraft operations.
Definition study for an extended manned test of a regenerative life support system
NASA Technical Reports Server (NTRS)
1971-01-01
A program was defined which consists of extended ground-based manned tests of regenerative life support systems. The tests are to evaluate prototypes of advanced life support systems under operational, integrated conditions, thus providing data for the design of efficient environmental control and life support systems for use in long-duration space missions. The requirements are defined for test operations to provide a simulation of an orbiting space laboratory. The features of Phase A and B programs are described. These tests use proven backup equipment to ensure successful evaluation of the advanced subsystems. A pre-tests all-systems checkout period is provided to minimize equipment problems during extended testing and to familiarize all crew and operating staff members with test equipment and procedures.
An aerial radiological survey of the Nevada Test Site
DOE Office of Scientific and Technical Information (OSTI.GOV)
Hendricks, T J; Riedhauser, S R
1999-12-01
A team from the Remote Sensing Laboratory conducted an aerial radiological survey of the US Department of Energy's Nevada Test Site including three neighboring areas during August and September 1994. The survey team measured the terrestrial gamma radiation at the Nevada Test Site to determine the levels of natural and man-made radiation. This survey included the areas covered by previous surveys conducted from 1962 through 1993. The results of the aerial survey showed a terrestrial background exposure rate that varied from less than 6 microroentgens per hour (mR/h) to 50 mR/h plus a cosmic-ray contribution that varied from 4.5 mR/hmore » at an elevation of 900 meters (3,000 feet) to 8.5 mR/h at 2,400 meters (8,000 feet). In addition to the principal gamma-emitting, naturally occurring isotopes (potassium-40, thallium-208, bismuth-214, and actinium-228), the man-made radioactive isotopes found in this survey were cobalt-60, cesium-137, europium-152, protactinium-234m an indicator of depleted uranium, and americium-241, which are due to human actions in the survey area. Individual, site-wide plots of gross terrestrial exposure rate, man-made exposure rate, and americium-241 activity (approximating the distribution of all transuranic material) are presented. In addition, expanded plots of individual areas exhibiting these man-made contaminations are given. A comparison is made between the data from this survey and previous aerial radiological surveys of the Nevada Test Site. Some previous ground-based measurements are discussed and related to the aerial data. In regions away from man-made activity, the exposure rates inferred from the gamma-ray measurements collected during this survey agreed very well with the exposure rates inferred from previous aerial surveys.« less
NASA Technical Reports Server (NTRS)
Nolan, Sean; Neubek, Deb; Baxmann, C. J.
1988-01-01
The Manned Mars Explorer (MME) project responds to the fundamental problems of sending human beings to Mars in a mission scenario and schematic vehicle designs. The mission scenario targets an opposition class Venus inbound swingby for its trajectory with concentration on Phobos and/or Deimos as a staging base for initial and future Mars vicinity operations. Optional vehicles are presented as a comparison using nuclear electric power/propulsion technology. A Manned Planetary Vehicle and Crew Command Vehicle are used to accomplish the targeted mission. The Manned Planetary Vehicle utilizes the mature technology of chemical propulsion combined with an advanced aerobrake, tether and pressurized environment system. The Crew Command Vehicle is the workhorse of the mission performing many different functions including a manned Mars landing, and Phobos rendezvous.
Inhibition of processing of plant N-linked oligosaccharides by castanospermine.
Hori, H; Pan, Y T; Molyneux, R J; Elbein, A D
1984-02-01
Castanospermine (1,6,7,8-tetrahydroxyoctahydroindolizine) is a plant alkaloid that inhibits lysosomal alpha- and beta-glucosidase. It also inhibits processing of influenza viral glycoproteins by inhibiting glucosidase I and leads to altered glycoproteins with Glc3Man7GlcNAc2 structures. Castanospermine was tested as an inhibitor of glycoprotein processing in suspension-cultured soybean cells. Soybean cells were pulse-labeled with [2-3H]mannose and chased for varying periods in unlabeled medium. In normal cells, the initial glycopeptides contained oligosaccharides having Glc3Man9GlcNAc2 to Glc1Man9GlcNAc2 structures and these were trimmed during the chase to Man9GlcNac2 to Man7GlcNAc2 structures. In the presence of castanospermine, no trimming of glucose residues occurred although some mannose residues were apparently still removed. Thus, the major oligosaccharide in the glycopeptides of castanospermine-incubated cells after a 90-min chase was a Glc3Man7GlcNAc2 structure. Smaller amounts of Glc3Man6GlcNAc2 and Glc3Man5GlcNAc2 were also identified. Thus, in plant cells, castanospermine also prevents the removal of the outermost glucose residue.
Wiring test program insulation material related properties
NASA Technical Reports Server (NTRS)
Reher, Heinz-Josef
1995-01-01
This viewgraph presentation provides an overview of activities at DASA-RI concerning the testing of wires for manned spacecraft, including test facilities, arc-tracking tests, flammability tests, microgravity tests, and standardization, and outlines future activities.
Key technologies for expeditions to Mars.
NASA Astrophysics Data System (ADS)
French, J. R., Jr.
A round-trip manned Mars landing mission, while difficult, is within the realm of today's technology. However, better understood and more practical advanced technologies offer promising improvements in mass performance, and some also enhance certain aspects of self-reliance for manned missions.
Mahmood, I
1998-05-01
Extrapolation of animal data to assess pharmacokinetic parameters in man is an important tool in drug development. Clearance, volume of distribution and elimination half-life are the three most frequently extrapolated pharmacokinetic parameters. Extensive work has been done to improve the predictive performance of allometric scaling for clearance. In general there is good correlation between body weight and volume, hence volume in man can be predicted with reasonable accuracy from animal data. Besides the volume of distribution in the central compartment (Vc), two other volume terms, the volume of distribution by area (Vbeta) and the volume of distribution at steady state (VdSS), are also extrapolated from animals to man. This report compares the predictive performance of allometric scaling for Vc, Vbeta and VdSS in man from animal data. The relationship between elimination half-life (t(1/2)) and body weight across species results in poor correlation, most probably because of the hybrid nature of this parameter. To predict half-life in man from animal data, an indirect method (CL=VK, where CL=clearance, V is volume and K is elimination rate constant) has been proposed. This report proposes another indirect method which uses the mean residence time (MRT). After establishing that MRT can be predicted across species, it was used to predict half-life using the equation MRT=1.44 x t(1/2). The results of the study indicate that Vc is predicted more accurately than Vbeta and VdSS in man. It should be emphasized that for first-time dosing in man, Vc is a more important pharmacokinetic parameter than Vbeta or VdSS. Furthermore, MRT can be predicted reasonably well for man and can be used for prediction of half-life.
A Rationale for Developmental Testing and Training.
ERIC Educational Resources Information Center
Arner, Robert S.
Man's phylogenetic development has resulted in a potential for environmental interaction in a symbolic and conceptual manner. There are ontogenetic requirements to develop such potential. The process by which man learns is sequential and involves perceptual-motor-cognitive abilities. There is an optimum respectivity period at each developmental…
Laura K Muller; Jeffrey M. Lorch; Daniel L. Lindner; Michael O' Connor; Andrea Gargas; David S. Blehert
2013-01-01
The fungus Geomyces destructans is the causative agent of white-nose syndrome (WNS), a disease that has killed millions of North American hibernating bats. We describe a real-time TaqMan PCR test that detects DNA from G. destructans by targeting a portion of the multicopy intergenic spacer region of the rRNA gene complex. The...
1991-08-01
a suspended man basket. All work, including Government investigations, was done from the man basket and in some instances from a boatswain’s chair...Teale, Somerton , etc.. The Enpasol recordings rely on the same basic principle. The Enpasol is a "black box" monitoring up to 8 drilling parameters...below, Kelly bar is center. Inspector being lowered into access shaft with a man basket. Note liner plates, left. Density test being taken in core
Proceedings of the 1986 IEEE international conference on systems, man and cybernetics
DOE Office of Scientific and Technical Information (OSTI.GOV)
Not Available
1986-01-01
This book presents the papers given at a conference on man-machine systems. Topics considered at the conference included neural model-based cognitive theory and engineering, user interfaces, adaptive and learning systems, human interaction with robotics, decision making, the testing and evaluation of expert systems, software development, international conflict resolution, intelligent interfaces, automation in man-machine system design aiding, knowledge acquisition in expert systems, advanced architectures for artificial intelligence, pattern recognition, knowledge bases, and machine vision.
A new one-man submarine is tested as vehicle for solid rocket booster retrieval
NASA Technical Reports Server (NTRS)
2000-01-01
A Diver Operator Plug (DOP) is being pulled down into the ocean by a newly designed one-man submarine known as DeepWorker 2000. The activity is part of an operation to attach the plug to a mockup of a solid rocket booster nozzle. DeepWorker 2000 is being tested on its ability to duplicate the sometimes hazardous job United Space Alliance (USA) divers perform to recover the expended boosters in the ocean after a launch. The boosters splash down in an impact area about 140 miles east of Jacksonville and after recovery are towed back to KSC for refurbishment by the specially rigged recovery ships. DeepWorker 2000 will be used in a demonstration during retrieval operations after the upcoming STS-101 launch. The submarine pilot will demonstrate capabilities to cut tangled parachute riser lines using a manipulator arm and attach the DOP to extract water and provide flotation for the booster. DeepWorker 2000 was built by Nuytco Research Ltd., North Vancouver, British Columbia. It is 8.25 feet long, 5.75 feet high, and weighs 3,800 pounds. USA is a prime contractor to NASA for the Space Shuttle program.
A new one-man submarine is tested as vehicle for solid rocket booster retrieval
NASA Technical Reports Server (NTRS)
2000-01-01
After a successful dive, the one-man submarine known as DeepWorker 2000 is lifted from Atlantic waters near Cape Canaveral, Fla., onto the deck of the Liberty Star, one of two KSC solid rocket booster recovery ships. Inside the sub is the pilot, Anker Rasmussen. The sub is being tested on its ability to duplicate the sometimes hazardous job United Space Alliance (USA) divers perform to recover the expended boosters in the ocean after a launch. The boosters splash down in an impact area about 140 miles east of Jacksonville and after recovery are towed back to KSC for refurbishment by the specially rigged recovery ships. DeepWorker 2000 will be used in a demonstration during retrieval operations after the upcoming STS-101 launch. The submarine pilot will demonstrate capabilities to cut tangled parachute riser lines using a manipulator arm and attach a Diver Operator Plug to extract water and provide flotation for the booster. DeepWorker 2000 was built by Nuytco Research Ltd., North Vancouver, British Columbia. It is 8.25 feet long, 5.75 feet high, and weighs 3,800 pounds. USA is a prime contractor to NASA for the Space Shuttle program.
A new one-man submarine is tested as vehicle for solid rocket booster retrieval
NASA Technical Reports Server (NTRS)
2000-01-01
At left, a manipulator arm on a one-man submarine demonstrates its ability to cut tangled parachute riser lines and place a Diver Operator Plug (top right) inside a mock solid rocket booster nozzle (center). Known as DeepWorker 2000, the sub is being tested on its ability to duplicate the sometimes hazardous job United Space Alliance (USA) divers perform to recover the expended boosters in the ocean after a launch. The boosters splash down in an impact area about 140 miles east of Jacksonville and after recovery are towed back to KSC for refurbishment by the specially rigged recovery ships. DeepWorker 2000 will be used in a demonstration during retrieval operations after the upcoming STS-101 launch. The submarine pilot will demonstrate capabilities to cut tangled parachute riser lines using a manipulator arm and attach the DOP to extract water and provide flotation for the booster. DeepWorker 2000 was built by Nuytco Research Ltd., North Vancouver, British Columbia. It is 8.25 feet long, 5.75 feet high, and weighs 3,800 pounds. USA is a prime contractor to NASA for the Space Shuttle program.
A study of a tissue equivalent gelatine based tissue substitute
DOE Office of Scientific and Technical Information (OSTI.GOV)
Spence, J.L.
1992-11-01
A study of several tissue substitutes for use as volumetric dosimeters was performed. The tissue substitutes studied included tissue substitutes from previous studies and from ICRU 44. The substitutes were evaluated for an overall match to Reference Man which was used as a basis for this study. The evaluation was based on the electron stopping power, the mass attenuation coefficient, the electron density, and the specific gravity. The tissue substitute chosen also had to be capable of changing from a liquid into a solid form to maintain an even distribution of thermoluminesent dosimetry (TLD) powder and then back to amore » liquid for recovery of the TLD powder without adversely effecting the TLD powder. The gelatine mixture provided the closest match to the data from Reference Man tissue. The gelatine mixture was put through a series of test to determine it's usefulness as a reliable tissue substitute. The TLD powder was cast in the gelatine mixture and recovered to determine if the TLD powder was adversely effected. The distribution of the TLD powder after being cast into the gelatin mixture was tested in insure an even was maintained.« less
A study of a tissue equivalent gelatine based tissue substitute
DOE Office of Scientific and Technical Information (OSTI.GOV)
Spence, Jody L.
1992-11-01
A study of several tissue substitutes for use as volumetric dosimeters was performed. The tissue substitutes studied included tissue substitutes from previous studies and from ICRU 44. The substitutes were evaluated for an overall match to Reference Man which was used as a basis for this study. The evaluation was based on the electron stopping power, the mass attenuation coefficient, the electron density, and the specific gravity. The tissue substitute chosen also had to be capable of changing from a liquid into a solid form to maintain an even distribution of thermoluminesent dosimetry (TLD) powder and then back to amore » liquid for recovery of the TLD powder without adversely effecting the TLD powder. The gelatine mixture provided the closest match to the data from Reference Man tissue. The gelatine mixture was put through a series of test to determine it`s usefulness as a reliable tissue substitute. The TLD powder was cast in the gelatine mixture and recovered to determine if the TLD powder was adversely effected. The distribution of the TLD powder after being cast into the gelatin mixture was tested in insure an even was maintained.« less
Human Performance in Continuous Operations. Volume 3. Technical Documentation
1980-03-01
completed for the U. S. Commander, V Corps. Artillery, by Manning (1978). Manning collected information which bears on the following three questions: 0 Can...performance data were not collected in these pre- liminary studies. Field Studies of Continuous Tank OperationsLI __ _ _ __ _ _ _ To simulate a combat...on routine, monotonous tasks tends A show rapid and severe decrement after peri- odk of more than 24 hours without sleep. I Increasing task complexity
Man-machine interface requirements - advanced technology
NASA Technical Reports Server (NTRS)
Remington, R. W.; Wiener, E. L.
1984-01-01
Research issues and areas are identified where increased understanding of the human operator and the interaction between the operator and the avionics could lead to improvements in the performance of current and proposed helicopters. Both current and advanced helicopter systems and avionics are considered. Areas critical to man-machine interface requirements include: (1) artificial intelligence; (2) visual displays; (3) voice technology; (4) cockpit integration; and (5) pilot work loads and performance.
Virtual reality applied to teletesting
NASA Astrophysics Data System (ADS)
van den Berg, Thomas J.; Smeenk, Roland J. M.; Mazy, Alain; Jacques, Patrick; Arguello, Luis; Mills, Simon
2003-05-01
The activity "Virtual Reality applied to Teletesting" is related to a wider European Space Agency (ESA) initiative of cost reduction, in particular the reduction of test costs. Reduction of costs of space related projects have to be performed on test centre operating costs and customer company costs. This can accomplished by increasing the automation and remote testing ("teletesting") capabilities of the test centre. Main problems related to teletesting are a lack of situational awareness and the separation of control over the test environment. The objective of the activity is to evaluate the use of distributed computing and Virtual Reality technology to support the teletesting of a payload under vacuum conditions, and to provide a unified man-machine interface for the monitoring and control of payload, vacuum chamber and robotics equipment. The activity includes the development and testing of a "Virtual Reality Teletesting System" (VRTS). The VRTS is deployed at one of the ESA certified test centres to perform an evaluation and test campaign using a real payload. The VRTS is entirely written in the Java programming language, using the J2EE application model. The Graphical User Interface runs as an applet in a Web browser, enabling easy access from virtually any place.
Schalasta, Gunnar; Speicher, Andrea; Börner, Anna; Enders, Martin
2016-04-01
Quantitating the level of hepatitis C virus (HCV) RNA is the standard of care for monitoring HCV-infected patients during treatment. The performances of commercially available assays differ for precision, limit of detection, and limit of quantitation (LOQ). Here, we compare the performance of the Hologic Aptima HCV Quant Dx assay (Aptima) to that of the Roche Cobas TaqMan HCV test, version 2.0, using the High Pure system (HPS/CTM), considered a reference assay since it has been used in trials defining clinical decision points in patient care. The assays' performance characteristics were assessed using HCV RNA reference panels and plasma/serum from chronically HCV-infected patients. The agreement between the assays for the 3 reference panels was good, with a difference in quantitation values of <0.5 log. High concordance was demonstrated between the assays for 245 clinical samples (kappa = 0.80; 95% confidence interval [CI], 0.720 to 0.881); however, Aptima detected and/or quantitated 20 samples that HPS/CTM did not detect, while Aptima did not detect 1 sample that was quantitated by HPS/CTM. For the 165 samples quantitated by both assays, the values were highly correlated (R= 0.98;P< 0.0001). The linearity of quantitation from concentrations of 1.4 to 6 log was excellent for both assays for all HCV genotypes (GT) tested (GT 1a, 1b, 2b, and 3a) (R(2)> 0.99). The assays had similar levels of total and intra-assay variability across all genotypes at concentrations from 1,000 to 25 IU/ml. Aptima had a greater analytical sensitivity, quantitating more than 50% of replicates at 25-IU/ml target. Aptima showed performance characteristics comparable to those of HPS/CTM and increased sensitivity, making it suitable for use as a clinical diagnostic tool on the fully automated Panther platform. Copyright © 2016 Schalasta et al.
Leiva, T; Cooke, R F; Aboin, A C; Drago, F L; Gennari, R; Vasconcelos, J L M
2014-02-01
The objective was to compare insulin resistance parameters in cows with adequate or excessive energy intake as well as in cows with excessive energy intake receiving Cr supplementation as chromium propionate. Thirteen multiparous, nonlactating Gir × Holstein cows were ranked by BW and BCS and assigned to 1 of 3 dietary treatments on d 0: 1) diet to meet their ME requirements without Cr supplementation (MAN; n = 4), 2) diet to exceed their ME requirements without Cr supplementation (HIGH; n = 4), and 3) HIGH with 2.5 g/d of chromium propionate (HIGHCR; n = 5, with 10 mg of Cr/cow daily). Diets were formulated to provide 100% of daily ME requirements of MAN and 177% of daily ME requirements of HIGH and HIGHCR cows and offered twice daily via individual self-locking head gates from d 0 to 88. Cow BW and BCS were recorded on d 0 and 88 of the experiment. Blood samples were collected before and 2 h after the morning feeding twice weekly. Preprandial revised quantitative insulin sensitivity check index (RQUICKI) was determined using serum glucose, insulin, and NEFA concentrations obtained before feeding. Glucose tolerance tests (GTT) were performed on d 32 and 88 by infusing cows with 0.5 g of glucose/kg of BW whereas blood samples were collected at -15, 0, 10, 20, 30, 45, 60, and 90 min relative to infusion. Change in BCS tended to be greater in HIGH and HIGHCR (P = 0.09) compared with MAN cows. Within samples collected twice weekly, serum concentrations of glucose, insulin (beginning on d 14 of the experiment), and NEFA (preprandial samples only) were greater (P ≤ 0.05) in HIGH compared with HIGHCR cows and tended to be greater in HIGH compared with MAN cows (P ≤ 0.10) but did not differ (P ≥ 0.52) between HIGHCR and MAN cows. Moreover, HIGH cows had reduced RQUICKI compared with MAN (P = 0.02) and HIGHCR cows (P = 0.05) whereas RQUICKI was similar between MAN and HIGHCR cows (P = 0.53). Within samples collected during the GTT, mean serum insulin concentrations and insulin:glucose ratio were greater (P < 0.01) in HIGH compared with HIGHCR cows, tended (P ≤ 0.09) to be greater in HIGH compared with MAN cows, and were similar (P ≥ 0.16) between HIGHCR and MAN cows. Serum glucose concentrations were greater (P < 0.01) for HIGH compared with MAN and HIGHCR cows 20 min relative to infusion. In conclusion, chromium propionate supplementation prevented the increase in insulin resistance caused by excessive energy intake in nonlactating dairy cows.
NASA Technical Reports Server (NTRS)
Duffy, James B.
1993-01-01
The purpose of the Advanced Transportation System Study (ATSS) task area 1 study effort is to examine manned launch vehicle booster concepts and two-way cargo transfer and return vehicle concepts to determine which of the many proposed concepts best meets NASA's needs for two-way transportation to low earth orbit. The study identified specific configurations of the normally unmanned, expendable launch vehicles (such as the National Launch System family) necessary to fly manned payloads. These launch vehicle configurations were then analyzed to determine the integrated booster/spacecraft performance, operations, reliability, and cost characteristics for the payload delivery and return mission. Design impacts to the expendable launch vehicles which would be required to perform the manned payload delivery mission were also identified. These impacts included the implications of applying NASA's man-rating requirements, as well as any mission or payload unique impacts. The booster concepts evaluated included the National Launch System (NLS) family of expendable vehicles and several variations of the NLS reference configurations to deliver larger manned payload concepts (such as the crew logistics vehicle (CLV) proposed by NASA JSC). Advanced, clean sheet concepts such as an F-1A engine derived liquid rocket booster (LRB), the single stage to orbit rocket, and a NASP-derived aerospace plane were also included in the study effort. Existing expendable launch vehicles such as the Titan 4, Ariane 5, Energia, and Proton were also examined. Although several manned payload concepts were considered in the analyses, the reference manned payload was the NASA Langley Research Center's HL-20 version of the personnel launch system (PLS). A scaled up version of the PLS for combined crew/cargo delivery capability, the HL-42 configuration, was also included in the analyses of cargo transfer and return vehicle (CTRV) booster concepts. In addition to strictly manned payloads, two-way cargo transportation systems (CTRV's) were also examined. The study provided detailed design and analysis of the performance, reliability, and operations of these concepts. The study analyzed these concepts as unique systems and also analyzed several combined CTRV/booster configurations as integrated launch systems (such as for launch abort analyses). Included in the set of CTRV concepts analyzed were the medium CTRV, the integral CTRV (in both a pressurized and unpressurized configuration), the winged CTRV, and an attached cargo carrier for the PLS system known as the PLS caboose.
NASA Technical Reports Server (NTRS)
Crane, D. F.
1984-01-01
When human operators are performing precision tracking tasks, their dynamic response can often be modeled by quasilinear describing functions. That fact permits analysis of the effects of delay in certain man machine control systems using linear control system analysis techniques. The analysis indicates that a reduction in system stability is the immediate effect of additional control system delay, and that system characteristics moderate or exaggerate the importance of the delay. A selection of data (simulator and flight test) consistent with the analysis is reviewed. Flight simulator visual-display delay compensation, designed to restore pilot aircraft system stability, was evaluated in several studies which are reviewed here. The studies range from single-axis, tracking-task experiments (with sufficient subjects and trials to establish the statistical significance of the results) to a brief evaluation of compensation of a computer generated imagery (CGI) visual display system in a full six degree of freedom simulation. The compensation was effective, improvements in pilot performance and workload or aircraft handling qualities rating (HQR) were observed. Results from recent aircraft handling qualities research literature, which support the compensation design approach, are also reviewed.
Human Factors Experiments for Data Link : Interim Report No. 5
DOT National Transportation Integrated Search
1975-02-01
One and two-man crews of general aviation pilots and two-man crews of FAA/NAFEC test pilots made a series of simulated flights in a GAT-2 simulator to evaluate various complements of I/O equipment for Data Link. In the earlier experiments in the seri...
Centaur Test Bed (CTB) for Cryogenic Fluid Management
NASA Technical Reports Server (NTRS)
Sakla, Steven; Kutter, Bernard; Wall, John
2006-01-01
Future missions such as NASA s space exploration vision and DOD satellite servicing will require significant increases in the understanding and knowledge of space based cryogenic fluid management (CFM), including the transfer and storage of cryogenic fluids. Existing CFM capabilities are based on flight of upper stage cryogenic vehicles, scientific dewars, a few dedicated flight demonstrations and ground testing. This current capability is inadequate to support development of the CEV cryogenic propulsion system, other aspects of robust space exploration or the refueling of satellite cryo propulsion systems with reasonable risk. In addition, these technologies can provide significant performance increases for missions beyond low-earth orbit to enable manned missions to the Moon and beyond. The Centaur upper-stage vehicle can provide a low cost test platform for performing numerous flight demonstrations of the full breadth of required CFM technologies to support CEV development. These flight demonstrations can be performed as secondary mission objectives using excess LH2 and/or LO2 from the main vehicle propellant tanks following primary spacecraft separation at minimal cost and risk.
Technical Evaluation Report, Part A - Vortex Flow and High Angle of Attack
NASA Technical Reports Server (NTRS)
Luckring, James M.
2003-01-01
A symposium entitled Vortex Flow and High Angle of Attack was held in Loen, Norway, from May 7 through May 11, 2001. The Applied Vehicle Technology (AVT) panel, under the auspices of the Research and Technology Organization (RTO), sponsored this symposium. Forty-eight papers, organized into nine sessions, addressed computational and experimental studies of vortex flows pertinent to both aircraft and maritime applications. The studies also ranged from fundamental fluids investigations to flight test results, and significant results were contributed from a broad range of countries. The principal emphasis of this symposium was on "the understanding and prediction of separation-induced vortex flows and their effects on military vehicle performance, stability, control, and structural design loads." It was further observed by the program committee that "separation- induced vortex flows are an important part of the design and off-design performance of conventional fighter aircraft and new conventional or unconventional manned or unmanned advanced vehicle designs (UAVs, manned aircraft, missiles, space planes, ground-based vehicles, and ships)." The nine sessions addressed the following topics: vortical flows on wings and bodies, experimental techniques for vortical flows, numerical simulations of vortical flows, vortex stability and breakdown, vortex flows in maritime applications, vortex interactions and control, vortex dynamics, flight testing, and vehicle design. The purpose of this paper is to provide brief reviews of these papers along with some synthesizing perspectives toward future vortex flow research opportunities. The paper includes the symposium program. (15 refs.)
Orbital construction support equipment - Manned remote work station
NASA Technical Reports Server (NTRS)
Nassiff, S. H.
1978-01-01
The Manned Remote Work Station (MRWS) is a versatile piece of orbital construction support equipment which can support in-space construction in various modes of operation. Proposed near-term Space Shuttle mission support and future large orbiting systems support, along with the various construction modes of MRWS operation, are discussed. Preliminary flight subsystems requirements and configuration design are presented. Integration of the MRWS development test article with the JSC Mockup and Integration Facility, including ground-test objectives and techniques for zero-g simulations, is also presented.
Evaluation and characterization of the methane-carbon dioxide decomposition reaction
NASA Technical Reports Server (NTRS)
Davenport, R. J.; Schubert, F. H.; Shumar, J. W.; Steenson, T. S.
1975-01-01
A program was conducted to evaluate and characterize the carbon dioxide-methane (CO2-CH4) decomposition reaction, i.e., CO2 + CH4 = 2C + 2H2O. The primary objective was to determine the feasibility of applying this reaction at low temperatures as a technique for recovering the oxygen (O2) remaining in the CO2 which exits mixed with CH4 from a Sabatier CO2 reduction subsystem (as part of an air revitalization system of a manned spacecraft). A test unit was designed, fabricated, and assembled for characterizing the performance of various catalysts for the reaction and ultraviolet activation of the CH4 and CO2. The reactor included in the test unit was designed to have sufficient capacity to evaluate catalyst charges of up to 76 g (0.17 lb). The test stand contained the necessary instrumentation and controls to obtain the data required to characterize the performance of the catalysts and sensitizers tested: flow control and measurement, temperature control and measurement, product and inlet gas analysis, and pressure measurement. A product assurance program was performed implementing the concepts of quality control and safety into the program effort.
NASA Technical Reports Server (NTRS)
Mckee, J. W.
1974-01-01
Experiments are performed during manned space flights in an attempt to acquire knowledge that can advance science and technology or that can be applied to operational techniques for future space flights. A description is given of the procedures that the personnel who are directly assigned to the function of crew support at the NASA Lyndon B. Johnson Space Center use to prepare for and to conduct experiments during space flight.
Passive Fingerprinting Of Computer Network Reconnaissance Tools
2009-09-01
v6 for version 6 MITM : Man-In-The-Middle Attack MSS: Maximum Segment Size NOP: No Operation Performed NPS: Naval Postgraduate School OS...specific, or man-in-the- middle ( MITM ) attacks. Depending on the attacker’s position to access the targeted network, the attacker may be able to...identification numbers. Both are ordinarily supposed to be initialized as a random number to make it difficult for an attacker to perform an injection MITM
Flight Performance of a Man Portable Guided Projectile Concept
2014-02-01
include precision guided technologies. The focus of this study is maneuvering projectiles launched from man portable weapon systems . A novel guided...5 Figure 5. Body-fixed coordinate system and aerodynamic angles...20 Figure 20. Earth and body-fixed coordinate systems and Euler angles. ........................................24
One-man electrochemical air revitalization system evaluation
NASA Technical Reports Server (NTRS)
Schbert, F. H.; Marshall, R. D.; Hallick, T. M.; Woods, R. R.
1976-01-01
A program to evaluate the performance of a one man capacity, self contained electrochemical air revitalization system was successfully completed. The technology readiness of this concept was demonstrated by characterizing the performance of this one man system over wide ranges in cabin atmospheric conditions. The electrochemical air revitalization system consists of a water vapor electrolysis module to generate oxygen from water vapor in the cabin air, and an electrochemical depolarized carbon dioxide concentrator module to remove carbon dioxide from the cabin air. A control/monitor instrumentation package that uses the electrochemical depolarized concentrator module power generated to partially offset the water vapor electrolysis module power requirements and various structural fluid routing components are also part of the system. The system was designed to meet the one man metabolic oxygen generation and carbon dioxide removal requirements, thereby controlling cabin partial pressure of oxygen at 22 kN/sq m and cabin pressure of carbon dioxide at 400 N/sq m over a wide range in cabin air relative humidity conditions.
Clinical evaluation of Roche COBAS® AmpliPrep/COBAS® TaqMan® CMV Test using non-plasma samples.
Hildenbrand, Cynthia; Wedekind, Laura; Li, Ge; vonRentzell, Jeanne E; Shah, Krunal; Rooney, Paul; Harrington, Amanda T; Zhao, Richard Y
2018-05-24
Cytomegalovirus (CMV) infection is a leading cause of loss of hearing, vision, and mental retardation in congenitally infected children. It is also associated with complications of organ-transplant and opportunistic HIV co-infection. The Roche COBAS ® AmpliPrep/COBAS ® TaqMan ® CMV Test is a FDA-approved test that measures CMV DNA viral load in plasma for the diagnosis and management of patients at risk for CMV-associated diseases. Besides plasma, CMV is often found in bronchoalveolar lavage (BAL), cerebrospinal fluid (CSF) and urine. Thus, monitoring of CMV for critical care of patients in these non-plasma samples becomes necessary. The objective of this study was to conduct an analytic and clinical feasibility study of the Roche CMV Test in BAL, CSF, and urine. The lower limit of detection (LOD), analytic measurement range (AMR), assay sensitivity, specificity, and precision were determined. Results of this study showed the LODs were 50, 100 and 300 IU/mL for BAL, CSF, or urine, respectively. The AMRs were from log 10 2.48 to log 10 5.48. The assay specificity was 94.4% for BAL, and 100% for CSF and urine. The assay precision was all within the acceptable range. The performance of Roche test was further compared with two comparators including the RealTime CMV Assay (Abbott Molecular) and a CMV Quantitative PCR Test (Vela Diagnostics). There was a general positive correlation between the Roche method and the Abbott or the Vela method. Overall, this study suggests the Roche CMV Test is suitable for the quantification of CMV viral load DNA in the described non-plasma samples. This article is protected by copyright. All rights reserved. This article is protected by copyright. All rights reserved.
Thermal human phantom for testing of millimeter wave cameras
NASA Astrophysics Data System (ADS)
Palka, Norbert; Ryniec, Radoslaw; Piszczek, Marek; Szustakowski, Mieczyslaw; Zyczkowski, Marek; Kowalski, Marcin
2012-06-01
Screening cameras working in millimetre band gain more and more interest among security society mainly due to their capability of finding items hidden under clothes. Performance of commercially available passive cameras is still limited due to not sufficient resolution and contrast in comparison to other wavelengths (visible or infrared range). Testing of such cameras usually requires some persons carrying guns, bombs or knives. Such persons can have different clothes or body temperature, what makes the measurements even more ambiguous. To avoid such situations we built a moving phantom of human body. The phantom consists of a polystyrene manikin which is covered with a number of small pipes with water. Pipes were next coated with a silicone "skin". The veins (pipes) are filled with water heated up to 37 C degrees to obtain the same temperature as human body. The phantom is made of non-metallic materials and is placed on a moving wirelessly-controlled platform with four wheels. The phantom can be dressed with a set of ordinary clothes and can be equipped with some dangerous (guns, bombs) and non-dangerous items. For tests we used a passive commercially available camera TS4 from ThruVision Systems Ltd. operating at 250 GHz. We compared the images taken from phantom and a man and we obtained good similarity both for naked as well as dressed man/phantom case. We also tested the phantom with different sets of clothes and hidden items and we got good conformity with persons.
Low Temperature Life-cycle Testing of a Lithium-ion Battery for Low-earth-orbiting Spacecraft
NASA Technical Reports Server (NTRS)
Reid, Concha
2004-01-01
A flight-qualified, lithium-ion (Li-ion) battery developed for the Mars Surveyor Program 2001 lander is undergoing life-testing at low temperature under a low-Earth-orbit (LEO) profile to assess its capability to provide long term energy storage for aerospace missions. NASA has embarked upon an ambitious course to return humans to the moon by 2015-2020 in preparation for robotic and human exploration of Mars and robotic exploration of the moons of outer planets. Li-ion batteries are excellent candidates to provide power and energy storage for multiple aspects of these missions due to their low specific energy, low energy density, and excellent low temperature performance. Laboratory testing of Li-ion technology is necessary in order to assess lifetime, characterize multi-cell battery-level performance under aerospace conditions, and to gauge safety aspects of the technology. Life-cycle testing provides an opportunity to examine battery-level performance and the dynamics of individual cells in the stack over the entire life of the battery. Data generated through this testing will be critical to establish confidence in the technology for its widespread use in manned and unmanned mission. This paper discusses the performance of the 28 volt, 25 ampere-hour battery through 6000 LEO cycles, which corresponds to one year on LEO orbit. Testing is being performed at 0 C and 40% depth-of-discharge. Individual cell behaviors and their effect on the performance of the battery are described. Capacity, impedance, energy efficiency and end-of-discharge voltage at 1000 cycle intervals are reported. Results from this life-testing will help contribute to the database on battery-level performance of aerospace Li-ion batteries and low temperature cycling under LEO conditions.
EVA assembly of large space structure element
NASA Technical Reports Server (NTRS)
Bement, L. J.; Bush, H. G.; Heard, W. L., Jr.; Stokes, J. W., Jr.
1981-01-01
The results of a test program to assess the potential of manned extravehicular activity (EVA) assembly of erectable space trusses are described. Seventeen tests were conducted in which six "space-weight" columns were assembled into a regular tetrahedral cell by a team of two "space"-suited test subjects. This cell represents the fundamental "element" of a tetrahedral truss structure. The tests were conducted under simulated zero-gravity conditions. Both manual and simulated remote manipulator system modes were evaluated. Articulation limits of the pressure suit and zero gravity could be accommodated by work stations with foot restraints. The results of this study have confirmed that astronaut EVA assembly of large, erectable space structures is well within man's capabilities.
Isotope heat source simulator for testing of space power systems
NASA Technical Reports Server (NTRS)
Prok, G. M.; Smith, R. B.
1973-01-01
A reliable isotope heat source simulator was designed for use in a Brayton power system. This simulator is composed of an electrically heated tungsten wire which is wound around a boron nitride core and enclosed in a graphite jacket. Simulator testing was performed at the expected operating temperature of the Brayton power system. Endurance testing for 5012 hours was followed by cycling the simulator temperature. The integrity of this simulator was maintained throughout testing. Alumina beads served as a diffusion barrier to prevent interaction between the tungsten heater and boron nitride core. The simulator was designed to maintain a surface temperature of 1311 to 1366 K (1900 to 2000 F) with a power input of approximately 400 watts. The design concept and the materials used in the simulator make possible man different geometries. This flexibility increases its potential use.
Results of the International Space Station Interim Resistance Exercise Device Man-in-the-Loop Test
NASA Technical Reports Server (NTRS)
Moore, A. D., Jr.; Amonette, W. E.; Bentley, J. R.; Rapley, M. G.; Blazine, K. L.; Loehr, J. A.; Collier, K. R.; Boettcher, C. R.; Skrocki, J. S.; Hohrnann, R. J.
2004-01-01
The Interim Resistance Exercise Device (iRED), developed for the International Space Station (ISS), was evaluated using human subjects for a Man-In-The-Loop Test (MILT). Thirty-two human subjects exercised using the iRED in a test that was conducted over a 63-working-day period. The subjects performed the same exercises will be used on board ISS, and the iRED operating constraints that are to be used on ISS were followed. In addition, eight of the subjects were astronauts who volunteered to be in the evaluation in order to become familiar with the iRED and provide a critique of the device. The MILT was scheduled to last for 57,000 exercise repetitions on the iRED. This number of repetitions was agreed to as a number typical of that expected during a 3-person, 17-week ISS Increment. One of the canisters of the iRED failed at the 49,683- repetition mark (87.1% of targeted goal). The remaining canister was operated using the plan for operations if one canister fails during flight (contingency operations). This canister remained functional past the 57,000-repetition mark. This report details the results of the iRED MILT, and lists specific recommendations regarding both operation of the iRED and future resistance exercise device development.
Distributed Aerodynamic Sensing and Processing Toolbox
NASA Technical Reports Server (NTRS)
Brenner, Martin; Jutte, Christine; Mangalam, Arun
2011-01-01
A Distributed Aerodynamic Sensing and Processing (DASP) toolbox was designed and fabricated for flight test applications with an Aerostructures Test Wing (ATW) mounted under the fuselage of an F-15B on the Flight Test Fixture (FTF). DASP monitors and processes the aerodynamics with the structural dynamics using nonintrusive, surface-mounted, hot-film sensing. This aerodynamic measurement tool benefits programs devoted to static/dynamic load alleviation, body freedom flutter suppression, buffet control, improvement of aerodynamic efficiency through cruise control, supersonic wave drag reduction through shock control, etc. This DASP toolbox measures local and global unsteady aerodynamic load distribution with distributed sensing. It determines correlation between aerodynamic observables (aero forces) and structural dynamics, and allows control authority increase through aeroelastic shaping and active flow control. It offers improvements in flutter suppression and, in particular, body freedom flutter suppression, as well as aerodynamic performance of wings for increased range/endurance of manned/ unmanned flight vehicles. Other improvements include inlet performance with closed-loop active flow control, and development and validation of advanced analytical and computational tools for unsteady aerodynamics.
Presentation of the Letter of Offer and Acceptance to Iran for the F-16: A Case Study.
1979-06-01
terms of man- power and/or dollars? a. Man-years $ (Contract). b. Man-years $ (In-house). 4. Often it is not possible to attach equivalent dollar...the program, as well as its recent expasion into some sensitive centers of power - iran, Israel, Saudi Arabia, Egypt-have brought arms transfers...tasks are to be performed, and how much money is involved, the LOA is a uniquely powerful document. Yet surprisingly, the first-and only--analysis and
Humanoid Flight Metabolic Simulator Project
NASA Technical Reports Server (NTRS)
Ross, Stuart
2015-01-01
NASA's Evolvable Mars Campaign (EMC) has identified several areas of technology that will require significant improvements in terms of performance, capacity, and efficiency, in order to make a manned mission to Mars possible. These include crew vehicle Environmental Control and Life Support System (ECLSS), EVA suit Portable Life Support System (PLSS) and Information Systems, autonomous environmental monitoring, radiation exposure monitoring and protection, and vehicle thermal control systems (TCS). (MADMACS) in a Suit can be configured to simulate human metabolism, consuming crew resources (oxygen) in the process. In addition to providing support for testing Life Support on unmanned flights, MADMACS will also support testing of suit thermal controls, and monitor radiation exposure, body zone temperatures, moisture, and loads.
Chen, Jing; Chen, Yuchao; Cheng, Yi; Gao, Youheng
2017-09-24
Mannose-diester lauric diacid-cholesterol (Man-DLD-Chol), as a liposomal target ligand, was synthesized by lipase catalyzed in a non-aqueous medium. Its chemical structure was confirmed by mass spectrometry (MS) and nuclear magnetic resonance (NMR) spectroscopy. Glycyrrhetinic acid (GA) liposomes containing Man-DLD-Chol (Man-DLD-Chol-GA-Lp) were prepared by the film-dispersion method. We evaluated the characterizations of liposomes, drug-release in vitro, the hemolytic test, cellular uptake, pharmacokinetics, and the tissue distributions. The cellular uptake in vitro suggested that the uptake of Man-DLD-Chol-modified liposomes was significantly higher than that of unmodified liposomes in HepG2 cells. Pharmacokinetic parameters indicated that Man-DLD-Chol-GA-Lp was eliminated more rapidly than GA-Lp. In tissue distributions, the targeting efficiency (Te) of Man-DLD-Chol-GA-Lp on liver was 54.67%, relative targeting efficiency (R Te ) was 3.39, relative uptake rate (Re) was 4.78, and peak concentration ratio (Ce) was 3.46. All these results supported the hypothesis that Man-DLD-Chol would be an efficient liposomal carrier, and demonstrated that Man-DLD-Chol-GA-Lp has potential as a drug delivery for liver-targeting therapy.
Yadav, Reena; Paria, Anutosh; Mankame, Smruti; Makesh, M; Chaudhari, Aparna; Rajendran, K V
2015-12-01
Hepatopancreatic parvovirus (HPV) infects Penaeus monodon and causes mortality in the larval stages. Further, it has been implicated in the growth retardation in cultured P. monodon. Though different geographical isolates of HPV show large sequence variations, a sensitive PCR assay specific to Indian isolate has not yet been reported. Here, we developed a sensitive SYBR Green-based and TaqMan real-time PCR for the detection and quantification of the virus. A 441-bp PCR amplicon was cloned in pTZ57 R/T vector and the plasmid copy number was estimated. A 10-fold serial dilution of the plasmid DNA from 1 × 10(9) copies to 1 copy was prepared and used as the standard. The primers were tested initially using the standard on a conventional PCR format to determine the linearity of detection. The standards were further tested on real-time PCR format using SYBR Green and TaqMan chemistry and standard curves were generated based on the Ct values from three well replicates for each dilution. The assays were found to be sensitive, specific and reproducible with a wide dynamic range (1 × 10(9) to 10 copies) with coefficient of regression (R(2)) > 0.99, calculated average slope -3.196 for SYBR Green assay whereas, for TaqMan assay it was >0.99 and -3.367, respectively. The intra- and inter-assay variance of the Ct values ranged from 0.26% to 0.94% and 0.12% to 0.81%, respectively, for SYBR Green assay, and the inter-assay variance of the Ct values for TaqMan assay ranged from 0.07% to 1.93%. The specificity of the assays was proved by testing other DNA viruses of shrimp such as WSSV, IHHNV and MBV. Standardized assays were further tested to detect and quantify HPV in the post-larvae of P. monodon. The result was further compared with conventional PCR to test the reproducibility of the test. The assay was also used to screen Litopeneaus vannamei, Macrobrachium rosenbergii and Scylla serrata for HPV. Copyright © 2015 Elsevier Ltd. All rights reserved.
THE DESIGN OF A MAN-MACHINE COUNSELING SYSTEM. A PROFESSIONAL PAPER.
ERIC Educational Resources Information Center
COGSWELL, J.F.; AND OTHERS
TWO PROJECTS ON THE DESIGN, DEVELOPMENT, IMPLEMENTATION, AND EVALUATION OF A MAN-MACHINE SYSTEM FOR COUNSELING IN THE PALO ALTO AND LOS ANGELES SCHOOL DISTRICTS ARE REPORTED. THE EARLIER PHILCO 2000 COMPUTER PROGRAMS SIMULATED A COUNSELOR'S WORK IN THE EDUCATIONAL PLANNING INTERVIEW BY ACCEPTING INPUTS SUCH AS SCHOOL GRADES, TEST SCORES, AND…
Aerial shows Stennis test stands
2004-04-16
An aerial photo shows the B-1/B-2 Test Stand (foreground), A-2 Test Stand (middle) and A-1 Test Stand (back). The historic stands have been used to test engines used on every manned Apollo and space shuttle mission.
Manned Versus Unmanned Risk and Complexity Considerations for Future Midsized X-Planes
NASA Technical Reports Server (NTRS)
Lechniak, Jason A.; Melton, John E.
2017-01-01
The objective of this work was to identify and estimate complexity and risks associated with the development and testing of new low-cost medium-scale X-plane aircraft primarily focused on air transport operations. Piloting modes that were evaluated for this task were manned, remotely piloted, and unmanned flight research programs. This analysis was conducted early in the data collection period for X-plane concept vehicles before preliminary designs were complete. Over 50 different aircraft and system topics were used to evaluate the three piloting control modes. Expert group evaluations from a diverse set of pilots, engineers, and other experts at Aeronautics Research Mission Directorate centers within the National Aeronautics and Space Administration provided qualitative reasoning on the many issues surrounding the decisions regarding piloting modes. The group evaluations were numerically rated to evaluate each topic quantitatively and were used to provide independent criteria for vehicle complexity and risk. An Edwards Air Force Base instruction document was identified that emerged as a source of the effects found in our qualitative and quantitative data. The study showed that a manned aircraft was the best choice to align with test activities for transport aircraft flight research from a low-complexity and low-risk perspective. The study concluded that a manned aircraft option would minimize the risk and complexity to improve flight-test efficiency and bound the cost of the flight-test portion of the program. Several key findings and discriminators between the three modes are discussed in detail.
Results from On-Orbit Testing of the Fram Memory Test Experiment on the Fastsat Micro-Satellite
NASA Technical Reports Server (NTRS)
MacLeod, Todd C.; Sims, W. Herb; Varnavas, Kosta A.; Ho, Fat D.
2011-01-01
NASA is planning on going beyond Low Earth orbit with manned exploration missions. The radiation environment for most Low Earth orbit missions is harsher than at the Earth's surface but much less harsh than deep space. Development of new electronics is needed to meet the requirements of high performance, radiation tolerance, and reliability. The need for both Volatile and Non-volatile memory has been identified. Emerging Non-volatile memory technologies (FRAM, C-RAM,M-RAM, R-RAM, Radiation Tolerant FLASH, SONOS, etc.) need to be investigated for use in Space missions. An opportunity arose to fly a small memory experiment on a high inclination satellite (FASTSAT). An off-the-shelf 512K Ramtron FRAM was chosen to be tested in the experiment.
Numerical and flight simulator test of the flight deterioration concept
NASA Technical Reports Server (NTRS)
Mccarthy, J.; Norviel, V.
1982-01-01
Manned flight simulator response to theoretical wind shear profiles was studied in an effort to calibrate fixed-stick and pilot-in-the-loop numerical models of jet transport aircraft on approach to landing. Results of the study indicate that both fixed-stick and pilot-in-the-loop models overpredict the deleterious effects of aircraft approaches when compared to pilot performance in the manned simulator. Although the pilot-in-the-loop model does a better job than does the fixed-stick model, the study suggests that the pilot-in-the-loop model is suitable for use in meteorological predictions of adverse low-level wind shear along approach and departure courses to identify situations in which pilots may find difficulty. The model should not be used to predict the success or failure of a specific aircraft. It is suggested that the pilot model be used as part of a ground-based Doppler radar low-level wind shear detection and warning system.
Water Recovery System Design to Accommodate Dormant Periods for Manned Missions
NASA Technical Reports Server (NTRS)
Tabb, David; Carter, Layne
2015-01-01
Future manned missions beyond lower Earth orbit may include intermittent periods of extended dormancy. Under the NASA Advanced Exploration System (AES) project, NASA personnel evaluated the viability of the ISS Water Recovery System (WRS) to support such a mission. The mission requirement includes the capability for life support systems to support crew activity, followed by a dormant period of up to one year, and subsequently for the life support systems to come back online for additional crewed missions. Dormancy could be a critical issue due to concerns with microbial growth or chemical degradation that might prevent water systems from operating properly when the crewed mission began. As such, it is critical that the water systems be designed to accommodate this dormant period. This paper details the results of this evaluation, which include identification of dormancy issues, results of testing performed to assess microbial stability of pretreated urine during dormancy periods, and concepts for updating to the WRS architecture and operational concepts that will enable the ISS WRS to support the dormancy requirement.
[Results of salad machine experiment within the MARS-500 project].
Berkovich, Iu A; Erokhin, A N; Ziablova, N V; Krivobok, A S; Krivobok, N M; Smolianina, S O; Mukhamedieva, L N; Pakhomova, A A; Novikova, N D; Poddubko, S V; Korsak, I V
2012-01-01
The salad machine experiment was aimed to fulfill performance testing of a prototype of space conveyor-type cylindrical greenhouse PHYTOCYCLE-SL, to study growth and development of plants, and to evaluate microbial contamination of equipment in the closed manned environment. Crops of leaf cabbage Brassica chinensis L., cultivar Vesnianka were raised in the time interval between MARS-500 days 417 and 515. The greenhouse proved it serviceability demanding 17 min/(man x d) in the normal mode. Most likely that the slow growth rate and deviations in plant morphology were caused by the presence of volatile pollutants in the greenhouse compartment Accumulation of micromycetes was observed at the sites of humid surfaces contact with ambient air; reduction of the artificial soil area contacting with air decreased population of micromycetes in 40 times. Cabbage leafs were free of pathogenic microflora. These results of the experiment helped develop recommendations on how to work out some units and systems in projectable greenhouse VITACYCLE-T
How Surface Treatments Enhance Ground Handling
NASA Technical Reports Server (NTRS)
Yager, Thomas J.
2002-01-01
Several runway surface treatments developed in recent years are described in terms of how aircraft tire landing and takeoff friction requirements are met, particularly during adverse weather conditions. Changing the surface texture with grooving, grinding and shot peening, use of chemicals to remove or prevent accumulation of natural or man-made contaminants, and the use of new techniques and materials are discussed as means of improving surface friction performance. Test data are presented to illustrate the effects of runway conditions on aircraft ground performance. The severity of the problem of operating on runway surfaces which cannot provide sufficient aircraft tire friction capability is also illustrated from documented aircraft accident/incident reports. The paper concludes with recommendations for future pavement research activities.
NASA Astrophysics Data System (ADS)
Clements, Jim; Robinson, Richard; Bunt, Leslie; Robinson, Joe
2011-06-01
A number of techniques have been utilized to evaluate the performance of Aircraft Survivability Equipment (ASE) against threat Man-Portable Air Defense Systems (MANPADS). These techniques include flying actual threat MANPADS against stationary ASE with simulated aircraft signatures, testing installed ASE systems against simulated threat signatures, and laboratory hardware-in-the-loop (HWIL) testing with simulated aircraft and simulated missile signatures. All of these tests lack the realism of evaluating installed ASE against in-flight MANPADS on a terminal homing intercept path toward the actual ASE equipped aircraft. This limitation is due primarily to the current inability to perform non-destructive MANPADS/Aircraft flight testing. The U.S. Army Aviation and Missile Research and Development and Engineering Center (AMRDEC) is working to overcome this limitation with the development of a recoverable surrogate MANPADS missile system capable of engaging aircraft equipped with ASE while guaranteeing collision avoidance with the test aircraft. Under its Missile Airframe Simulation Testbed - MANPADS (MAST-M) program, the AMRDEC is developing a surrogate missile system which will utilize actual threat MANPADS seeker/guidance sections to control the flight of a surrogate missile which will perform a collision avoidance and recovery maneuver prior to intercept to insure non-destructive test and evaluation of the ASE and reuse of the MANPADS seeker/guidance section. The remainder of this paper provides an overview of this development program and intended use.
NASA Technical Reports Server (NTRS)
1975-01-01
Solid polymer electrolyte technology used in a water electrolysis system (WES) to generate oxygen and hydrogen for manned space station applications was investigated. A four-man rated, low pressure breadboard water electrolysis system with the necessary instrumentation and controls was fabricated and tested. A six man rated, high pressure, high temperature, advanced preprototype WES was developed. This configuration included the design and development of an advanced water electrolysis module, capable of operation at 400 psig and 200 F, and a dynamic phase separator/pump in place of a passive phase separator design. Evaluation of this system demonstrated the goal of safe, unattended automated operation at high pressure and high temperature with an accumulated gas generation time of over 1000 hours.
Design of Test Support Hardware for Advanced Space Suits
NASA Technical Reports Server (NTRS)
Watters, Jeffrey A.; Rhodes, Richard
2013-01-01
As a member of the Space Suit Assembly Development Engineering Team, I designed and built test equipment systems to support the development of the next generation of advanced space suits. During space suit testing it is critical to supply the subject with two functions: (1) cooling to remove metabolic heat, and (2) breathing air to pressurize the space suit. The objective of my first project was to design, build, and certify an improved Space Suit Cooling System for manned testing in a 1-G environment. This design had to be portable and supply a minimum cooling rate of 2500 BTU/hr. The Space Suit Cooling System is a robust, portable system that supports very high metabolic rates. It has a highly adjustable cool rate and is equipped with digital instrumentation to monitor the flowrate and critical temperatures. It can supply a variable water temperature down to 34 deg., and it can generate a maximum water flowrate of 2.5 LPM. My next project was to design and build a Breathing Air System that was capable of supply facility air to subjects wearing the Z-2 space suit. The system intakes 150 PSIG breathing air and regulates it to two operating pressures: 4.3 and 8.3 PSIG. It can also provide structural capabilities at 1.5x operating pressure: 6.6 and 13.2 PSIG, respectively. It has instrumentation to monitor flowrate, as well as inlet and outlet pressures. The system has a series of relief valves to fully protect itself in case of regulator failure. Both projects followed a similar design methodology. The first task was to perform research on existing concepts to develop a sufficient background knowledge. Then mathematical models were developed to size components and simulate system performance. Next, mechanical and electrical schematics were generated and presented at Design Reviews. After the systems were approved by the suit team, all the hardware components were specified and procured. The systems were then packaged, fabricated, and thoroughly tested. The next step was to certify the equipment for manned used, which included generating a Hazard Analysis and giving a presentation to the Test Readiness Review Board. Both of these test support systems will perform critical roles in the development of next-generation space suits. They will used on a regular basis to test the NASA's new Z-2 Space Suit. The Space Suit Cooling System is now the primary cooling system for all advanced suit tests.
Reisner, Sari L; Deutsch, Madeline B; Peitzmeier, Sarah M; White Hughto, Jaclyn M; Cavanaugh, Timothy; Pardee, Dana J; McLean, Sarah; Marrow, Elliot J; Mimiaga, Matthew J; Panther, Lori; Gelman, Marcy; Green, Jamison; Potter, Jennifer
2017-06-23
Cervical cancer, nearly all cases of which are caused by one of several high-risk strains of the human papillomavirus (hr-HPV), leads to significant morbidity and mortality in individuals with a cervix. Trans masculine (TM) individuals were born with female reproductive organs and identify as male, man, transgender man, or another diverse gender identity different from their female assigned sex at birth. Routine preventive sexual health screening of TM patients is recommended, including screening for cervical cancer and other sexually transmitted infections (STIs); however, as many as one in three TM patients are not up-to-date per recommended U.S. Among cisgender (non-transgender) women, self-swab hr.-HPV DNA testing as a primary cervical cancer screening method and self-swab specimen collection for other STIs have high levels of acceptability. No study has yet been conducted to compare the performance and acceptability of self- and provider-collected swabs for hr.-HPV DNA testing and other STIs in TM patients. This article describes the study protocol for a mixed-methods biobehavioral investigation enrolling 150 sexually active TM to (1) assess the clinical performance and acceptability of a vaginal self-swab for hr.-HPV DNA testing compared to provider cervical swab and cervical cytology, and (2) gather acceptability data on self-collected specimens for other STIs. Study participation entails a one-time clinical visit at Fenway Health in Boston, MA comprised of informed consent, quantitative assessment, venipuncture for syphilis testing and HIV (Rapid OraQuick) testing, randomization, collection of biological specimens/biomarkers, participant and provider satisfaction survey, and qualitative exit interview. Participants are compensated $100. The primary study outcomes are concordance (kappa statistic) and performance (sensitivity and specificity) of self-collected vaginal HPV DNA specimens vs provider-collected cervical HPV swabs as a gold standard. This study addresses critical gaps in current clinical knowledge of sexual health in TM patients, including comparing alternative strategies for screening and diagnosis of cervical cancer, hr.-HPV, and other STIs. Findings have implications for improving the delivery of sexual health screening to this often overlooked and underserved patient population. Less-invasive patient-centered strategies may also generalize to other at-risk cisgender female populations that face barriers to timely and needed STI and cervical cancer screening. ClinicalTrials.gov ID: NCT02401867.
Human performance issues arising from manned space station missions
NASA Technical Reports Server (NTRS)
Douglas, William K.
1986-01-01
Ten former NASA astronauts were interviewed using a set of 51 questions developed to encourage the contacts to discuss any thoughts, opinions, conclusions, or suggestions which might have evolved since they left the astronaut program. Strict confidentiality was maintained. At least one astronaut from each of the NASA manned space flight programs, excluding the Space Transportation System (Shuttle), was interviewed. The report records the answers to the questions asked, spontaneous comments, and the investigator's own personal evaluations of the material obtained. No statistical analysis of the material was attempted. The professional opinions of these ten experienced astronauts will be of value to persons concerned with the design and operation of manned spacecraft and manned space stations.
Dawson, Arthur; Loving, Richard T; Gordon, Robert M; Abel, Susan L; Loewy, Derek; Kripke, Daniel F; Kline, Lawrence E
2015-06-30
In its guidelines on the use of portable monitors to diagnose obstructive sleep apnoea, the American Academy of Sleep Medicine endorses home polygraphy with type III devices recording at a minimum airflow the respiratory effort and pulse oximetry, but advises against simple pulse oximetry. However, oximetry is widely available and simple to use in the home. This study was designed to compare the ability of the oxygen desaturation index (ODI) based on oximetry alone with a stand-alone pulse oximeter (SPO) and from the oximetry channel of the ApneaLink Plus (ALP), with the respiratory disturbance index (RDI) based on four channels from the ALP to predict the apnoea-hypopnoea index (AHI) from laboratory polysomnography. Cross-sectional diagnostic accuracy study. Sleep medicine practice of a multispecialty clinic. Patients referred for laboratory polysomnography with suspected sleep apnoea. We enrolled 135 participants with 123 attempting the home sleep testing and 73 having at least 4 hours of satisfactory data from SPO and ALP. Participants had home testing performed simultaneously with both a SPO and an ALP. The 2 oximeter probes were worn on different fingers of the same hand. The ODI for the SPO was calculated using Profox software (ODI(SOX)). For the ALP, RDI and ODI were calculated using both technician scoring (RDI(MAN) and ODI(MAN)) and the ALP computer scoring (RDI(RAW) and ODI(RAW)). The receiver-operator characteristic areas under the curve for AHI ≥ 5 were RDI(MAN) 0.88 (95% confidence limits 0.81-0.96), RDI(RAW) 0.86 (0.76-0.94), ODI(MAN) 0.86 (0.77-0.95), ODI(RAW) 0.84 (0.75-0.93) and ODI(SOX) 0.83 (0.73-0.93). We conclude that the RDI and the ODI, measured at home on the same night, give similar predictions of the laboratory AHI, measured on a different night. The differences between the two methods are small compared with the reported night-to-night variation of the AHI. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://group.bmj.com/group/rights-licensing/permissions.
Radiation protection using Martian surface materials in human exploration of Mars
NASA Technical Reports Server (NTRS)
Kim, M. H.; Thibeault, S. A.; Wilson, J. W.; Heilbronn, L.; Kiefer, R. L.; Weakley, J. A.; Dueber, J. L.; Fogarty, T.; Wilkins, R.
2001-01-01
To develop materials for shielding astronauts from the hazards of GCR, natural Martian surface materials are considered for their potential as radiation shielding for manned Mars missions. The modified radiation fluences behind various kinds of Martian rocks and regolith are determined by solving the Boltzmann equation using NASA Langley's HZETRN code along with the 1977 Solar Minimum galactic cosmic ray environmental model. To develop structural shielding composite materials for Martian surface habitats, theoretical predictions of the shielding properties of Martian regolith/polyimide composites has been computed to assess their shielding effectiveness. Adding high-performance polymer binders to Martian regolith to enhance structural properties also enhances the shielding properties of these composites because of the added hydrogenous constituents. Heavy ion beam testing of regolith simulant/polyimide composites is planned to validate this prediction. Characterization and proton beam tests are performed to measure structural properties and to compare the shielding effects on microelectronic devices, respectively.
[Acute hepatitis following amiodarone administration].
Tagliamonte, E; Cice, G; Ducceschi, V; Mayer, M S; Iacono, A
1997-09-01
A 61 year old man, treated with amiodarone since 1993 for resistant supraventricular arrhythmias, developed acute hepatitis after an intravenous amiodarone administration. Kidney and liver function tests were performed and pointed out abnormal results. Symptoms ascribable to hepatotoxicity were absent. These changes returned to normal levels within 20 days from withdrawal of the drug. Amiodarone hepatotoxicity can be related to prolonged therapy with a high dose. Intravenous amiodarone may cause acute hepatic disease, but it is suggested that polysorbate 80, a solvent added to the intravenous infusion, is a more likely cause of this complication.
Review of basic medical results of the Salyut-7-Soyuz-T 8-month manned flight
NASA Astrophysics Data System (ADS)
Gazenko, O. G.; Schulzhenko, E. B.; Grigoriev, A. I.; Atkov, O. Yu.; Egorov, A. D.
This paper presents the results of medical investigations performed in the Salyut-7 8-month mission in which a professional physician took part. The paper contains anthropometric measurements, results of investigating the vestibular function, cardiovascular function at rest and in response to multi-step tests (with emphasis on echocardiographic measurements), metabolic parameters and hormonal status. It also discusses medical aspects of the extravehicular activity. The medical investigations, although some new methods were applied, provided the continuity of methodical approaches and data accumulated in previous missions.
1961-10-13
usefulness is impaired, as by a failure of the light mstem. Adjusting is nscessary for efficiency of the power plant, as in carburetor adjustment or ignition...that thoz’e are two mamnals on the table behind Sgt. Craig. Valve adjustment is the task in the second photograph, The man bent over behind the power ...was no compreheiwion on our part cf the proficiency levels we wauld find. Or purpose actual2y -as to pin-point skill aW, kowledge deficiencies of the
[Cushing syndrome in a HIV patient using inhaled steroids. Report of one case].
Frías, Alondra; Ortiz, Alex; Soto, Miriam; Muñoz, Francisco; Chacón, Carolina
2016-07-01
We report a 41-year-old man with HIV and a chronic obstructive pulmonary disease, treated for seven months with Fluticasone/Salmeterol and antiretroviral therapy (Lamivudine, Tenofovir, Atazanavir and Ritonavir). While using these medications, the patients developed a Cushing syndrome in a period of five months. After performing laboratory and imaging tests, it was concluded that the most probable cause of the syndrome was the interaction of inhaled steroids with Ritonavir. After discontinuing these medications the syndrome reverted in a period of 8 months.
Technology advancements for the U.S. manned Space Station - An overview
NASA Technical Reports Server (NTRS)
Simon, William E.
1987-01-01
The structure and methodology of the Johnson Space Center (JSC) advanced development program is described. An overview of the program is given, and the technology transfer process to other disciplines is described. The test bed and flight experiment programs are described, as is the technology assessment which was performed at the end of the Phase B program. The technology program within each discipline is summarized, and the coordination and integration of the JSC program with the activities of other NASA centers and with work package contractors are discussed.
Influence of inspired oxygen concentration on the dynamics of the exercise hyperpnoea in man.
Griffiths, T L; Henson, L C; Whipp, B J
1986-01-01
In order to determine the role of the carotid bodies on the ventilatory control characteristics during the non-steady-state phase of exercise in man, six normal males performed cycle ergometry with four repetitions of a 6 min, constant-load work bout at inspired O2 fractions (FI,O2) of 0.12, 0.15, 0.21, 0.30 and 1.00. Each test began with unloaded pedalling; this was followed by a constant load which was 90% of the subject's anaerobic threshold at FI,O2 = 0.12. Ventilation (VE), CO2 output (VCO2) and O2 uptake (VO2) were determined breath-by-breath during the test and the time constants of response (tau VE, tau VCO2 and tau VO2) were established by least-squares techniques, following interpolation (1 s), temporal alignment and averaging of the four responses. In each subject, tau VE and tau VCO2 increased as functions of increasing FI,O2, and were inverse functions of the proportional contribution to VE of peripheral chemoreceptor drive (as estimated from hyperoxic-transition or 'Dejours' tests). tau VE averaged 40 s at FI,O2 = 0.12 and 112 s at FI,O2 = 1.00, each response being well fitted by a single exponential. However, tau VO2 was not significantly affected by the alterations in FI,O2. Although there was no discernible peripheral chemosensitivity at FI,O2 = 0.30 or 1.00, the tau VE increased appreciably between these inspirates. We therefore conclude that the peripheral chemoreceptors are important, but not exclusive determinants of the exponential response characteristics during the non-steady-state phase of the exercise hyperpnoea in man. This supports the contention of a component of the control being humorally mediated even during moderate exercise. PMID:3612567
NASA Astrophysics Data System (ADS)
Kryuchkov, B. I.; Usov, V. M.; Chertopolokhov, V. A.; Ronzhin, A. L.; Karpov, A. A.
2017-05-01
Extravehicular activity (EVA) on the lunar surface, necessary for the future exploration of the Moon, involves extensive use of robots. One of the factors of safe EVA is a proper interaction between cosmonauts and robots in extreme environments. This requires a simple and natural man-machine interface, e.g. multimodal contactless interface based on recognition of gestures and cosmonaut's poses. When travelling in the "Follow Me" mode (master/slave), a robot uses onboard tools for tracking cosmonaut's position and movements, and on the basis of these data builds its itinerary. The interaction in the system "cosmonaut-robot" on the lunar surface is significantly different from that on the Earth surface. For example, a man, dressed in a space suit, has limited fine motor skills. In addition, EVA is quite tiring for the cosmonauts, and a tired human being less accurately performs movements and often makes mistakes. All this leads to new requirements for the convenient use of the man-machine interface designed for EVA. To improve the reliability and stability of human-robot communication it is necessary to provide options for duplicating commands at the task stages and gesture recognition. New tools and techniques for space missions must be examined at the first stage of works in laboratory conditions, and then in field tests (proof tests at the site of application). The article analyzes the methods of detection and tracking of movements and gesture recognition of the cosmonaut during EVA, which can be used for the design of human-machine interface. A scenario for testing these methods by constructing a virtual environment simulating EVA on the lunar surface is proposed. Simulation involves environment visualization and modeling of the use of the "vision" of the robot to track a moving cosmonaut dressed in a spacesuit.
Air Evaporation closed cycle water recovery technology - Advanced energy saving designs
NASA Technical Reports Server (NTRS)
Morasko, Gwyndolyn; Putnam, David F.; Bagdigian, Robert
1986-01-01
The Air Evaporation water recovery system is a visible candidate for Space Station application. A four-man Air Evaporation open cycle system has been successfully demonstrated for waste water recovery in manned chamber tests. The design improvements described in this paper greatly enhance the system operation and energy efficiency of the air evaporation process. A state-of-the-art wick feed design which results in reduced logistics requirements is presented. In addition, several design concepts that incorporate regenerative features to minimize the energy input to the system are discussed. These include a recuperative heat exchanger, a heat pump for energy transfer to the air heater, and solar collectors for evaporative heat. The addition of the energy recovery devices will result in an energy reduction of more than 80 percent over the systems used in earlier manned chamber tests.
Coefficient of friction: tribological studies in man - an overview.
Sivamani, Raja K; Goodman, Jack; Gitis, Norm V; Maibach, Howard I
2003-08-01
Compared to other studies of skin, relatively few studies have focused on the friction of skin. This work reviews existing skin friction, emphasizing test apparatuses and parameters that have added to information regarding the friction coefficient. This review also outlines what factors are important to consider in future friction studies. Past studies have utilized numerous designs for a test apparatus, including probe geometry and material, as well as various probe motions (rotational vs. linear). Most tests were performed in vivo; a few were performed in vitro and on porcine skin. Differences in probe material, geometry and smoothness affect friction coefficient measurements. An increase in skin hydration, either through water or through moisturizer application, increases its friction coefficient; a decrease in skin hydration, either through clinical dermatitis or through alcohol addition, decreases the coefficient. Differences are present between anatomical sites. Conflicting results are found regarding age and no differences are apparent as a result of gender or race. Skin friction appears to be dependent on several factors - such as age, anatomical site and skin hydration. The choice of the probe and the test apparatus also influence the measurement.
Wise Guys: "The Man Who Knew Infinity" and Other Movies about Uppity Geniuses
ERIC Educational Resources Information Center
Beck, Bernard
2017-01-01
Conventional expectations about subcultural groups can be undermined by unusual performances of some individual members. Several recent movies have concerned people of exceptional ability who unexpectedly excelled at prestigious centers of learning. "The Man Who Knew Infinity," "The Imitation Game," and "The Theory of…
Art and the Special Child: Nine Case Studies.
ERIC Educational Resources Information Center
Brown, Eleese V.
1983-01-01
Nine special needs children who had been mainstreamed into regular classrooms were asked to draw a man and make a clay figure of a man. All but two of the children performed at the level of students of comparable mental age. Their clay figures were less sophisticated than their drawings. (IS)
Man's Search: English, Mythology. 5112.22.
ERIC Educational Resources Information Center
Gundersheimer, Lenore C.
A course which is an exploration of man's eternal search to understand himself and his world through the study of the mythology of the world is presented. Performance objectives include: (1) Students will recognize the content of the myths studied; (2) Students will identify the specific characteristics of the civilization studied; (3) Students…
Manipulator system man-machine interface evaluation program. [technology assessment
NASA Technical Reports Server (NTRS)
Malone, T. B.; Kirkpatrick, M.; Shields, N. L.
1974-01-01
Application and requirements for remote manipulator systems for future space missions were investigated. A manipulator evaluation program was established to study the effects of various systems parameters on operator performance of tasks necessary for remotely manned missions. The program and laboratory facilities are described. Evaluation criteria and philosophy are discussed.
Facilities and support systems for a 90-day test of a regenerative life support system
NASA Technical Reports Server (NTRS)
Malin, R. L.
1972-01-01
A 90-day test is reported of a regenerative life support system which was completed in a space station simulator. The long duration of the test and the fact that it was manned, imposed rigid reliability and safety requirements on the facility. Where adequate reliability could not be built into essential facility systems, either backup systems or components were provided. Awareness was intensified by: (1) placing signs on every piece of equipment that could affect the test, (2) painting switches on all breaker panels a bright contrasting color, (3) restricting access to the test control area, and (4) informing personnel in the facility (other than test personnel) of test activities. It is concluded that the basic facility is satisfactory for conducting long-duration manned tests, and it is recommended that all monitor and alarm functions be integrated into a single operation.
Flight telerobotic servicer legacy
NASA Astrophysics Data System (ADS)
Shattuck, Paul L.; Lowrie, James W.
1992-11-01
The Flight Telerobotic Servicer (FTS) was developed to enhance and provide a safe alternative to human presence in space. The first step for this system was a precursor development test flight (DTF-1) on the Space Shuttle. DTF-1 was to be a pathfinder for manned flight safety of robotic systems. The broad objectives of this mission were three-fold: flight validation of telerobotic manipulator (design, control algorithms, man/machine interfaces, safety); demonstration of dexterous manipulator capabilities on specific building block tasks; and correlation of manipulator performance in space with ground predictions. The DTF-1 system is comprised of a payload bay element (7-DOF manipulator with controllers, end-of-arm gripper and camera, telerobot body with head cameras and electronics module, task panel, and MPESS truss) and an aft flight deck element (force-reflecting hand controller, crew restraint, command and display panel and monitors). The approach used to develop the DTF-1 hardware, software and operations involved flight qualification of components from commercial, military, space, and R controller, end-of-arm tooling, force/torque transducer) and the development of the telerobotic system for space applications. The system is capable of teleoperation and autonomous control (advances state of the art); reliable (two-fault tolerance); and safe (man-rated). Benefits from the development flight included space validation of critical telerobotic technologies and resolution of significant safety issues relating to telerobotic operations in the Shuttle bay or in the vicinity of other space assets. This paper discusses the lessons learned and technology evolution that stemmed from developing and integrating a dexterous robot into a manned system, the Space Shuttle. Particular emphasis is placed on the safety and reliability requirements for a man-rated system as these are the critical factors which drive the overall system architecture. Other topics focused on include: task requirements and operational concepts for servicing and maintenance of space platforms; origins of technology for dexterous robotic systems; issues associated with space qualification of components; and development of the industrial base to support space robotics.
Space Suit Portable Life Support System (PLSS) 2.0 Human-in-the-Loop (HITL) Testing
NASA Technical Reports Server (NTRS)
Watts, Carly; Vogel, Matthew
2016-01-01
The space suit Portable Life Support System (PLSS) 2.0 represents the second integrated prototype developed and tested to mature a design that uses advanced technologies to reduce consumables, improve robustness, and provide additional capabilities over the current state of the art. PLSS 2.0 was developed in 2012, with extensive functional evaluations and system performance testing through mid-2014. In late 2014, PLSS 2.0 was integrated with the Mark III space suit in an ambient laboratory environment to facilitate manned testing, designated PLSS 2.0 Human-in-the-Loop (HITL) testing, in which the PLSS prototype performed the primary life support functions, including suit pressure regulation, ventilation, carbon dioxide control, and cooling of the test subject and PLSS avionics. The intent of this testing was to obtain subjective test subject feedback regarding qualitative aspects of PLSS 2.0 performance such as thermal comfort, sounds, smells, and suit pressure fluctuations due to the cycling carbon dioxide removal system, as well as to collect PLSS performance data over a range of human metabolic rates from 500-3000 Btu/hr. Between October 27 and December 18, 2014, nineteen two-hour simulated EVA test points were conducted in which suited test subjects walked on a treadmill to achieve a target metabolic rate. Six test subjects simulated nominal and emergency EVA conditions with varied test parameters including metabolic rate profile, carbon dioxide removal control mode, cooling water temperature, and Liquid Cooling and Ventilation Garment (state of the art or prototype). The nineteen test points achieved more than 60 hours of test time, with 36 hours accounting for simulated EVA time. The PLSS 2.0 test article performed nominally throughout the test series, confirming design intentions for the advanced PLSS. Test subjects' subjective feedback provided valuable insight into thermal comfort and perceptions of suit pressure fluctuations that will influence future advanced PLSS design and testing strategies.
Materials Control for Aerospace Applications
NASA Technical Reports Server (NTRS)
Ferguson, Michael
2005-01-01
The distant future of mankind and the ultimate survivability of the human race, as it is known today, will depend on mans' ability to break earthly bonds and establish new territorial positions throughout the universe. Man must therefore be positioned to not only travel to, but also, to readily adapt to numerous and varying environments. For this mass migration across the galaxies nothing is as import to the human race as is NASA's future missions into Low Earth Orbit (LEO), to the moon, and/or Mars. These missions will form the building blocks to eternity for mankind. From these missions, NASA will develop the foundations for these building blocks based on sound engineering and scientific principles, both known and yet to be discovered. The integrity of the program will lead to development, tracking and control of the most basic elements of hardware production: That being development and control of applications of space flight materials. Choosing the right material for design purposes involves many considerations, such as governmental regulations associated with manufacturing operations, both safety of usage and of manufacturing, general material usage requirements, material longevity and performance requirements, material interfacing compatibility and material usage environments. Material performance is subject to environmental considerations in as much as a given material may perform exceptionally well at standard temperatures and pressures while performing poorly under non-standard conditions. These concerns may be found true for materials relative to the extreme temperatures and vacuum gradients of high altitude usage. The only way to assure that flight worthy materials are used in design is through testing. However, as with all testing, it requires both time on schedule and cost to the operation. One alternative to this high cost testing approach is to rely on a materials control system established by NASA. The NASA community relies on the MAPTIS materials control system founded at MSFC and supported by the other NASA Centers. This system is a data bank of all materials used in space flight operations. These materials are rated for several characteristics that are common concerns in high altitude or deep space usage: Odor, off gassing, material fluid compatibility, toxicity, corrosion susceptibility, stress corrosion susceptibility, etc.
NASA Technical Reports Server (NTRS)
Atwell, William; Koontz, Steve; Normand, Eugene
2012-01-01
In this paper we review the discovery of cosmic ray effects on the performance and reliability of microelectronic systems as well as on human health and safety, as well as the development of the engineering and health science tools used to evaluate and mitigate cosmic ray effects in earth surface, atmospheric flight, and space flight environments. Three twentieth century technological developments, 1) high altitude commercial and military aircraft; 2) manned and unmanned spacecraft; and 3) increasingly complex and sensitive solid state micro-electronics systems, have driven an ongoing evolution of basic cosmic ray science into a set of practical engineering tools (e.g. ground based test methods as well as high energy particle transport and reaction codes) needed to design, test, and verify the safety and reliability of modern complex electronic systems as well as effects on human health and safety. The effects of primary cosmic ray particles, and secondary particle showers produced by nuclear reactions with spacecraft materials, can determine the design and verification processes (as well as the total dollar cost) for manned and unmanned spacecraft avionics systems. Similar considerations apply to commercial and military aircraft operating at high latitudes and altitudes near the atmospheric Pfotzer maximum. Even ground based computational and controls systems can be negatively affected by secondary particle showers at the Earth's surface, especially if the net target area of the sensitive electronic system components is large. Accumulation of both primary cosmic ray and secondary cosmic ray induced particle shower radiation dose is an important health and safety consideration for commercial or military air crews operating at high altitude/latitude and is also one of the most important factors presently limiting manned space flight operations beyond low-Earth orbit (LEO).
Real-time PCR and its application to mumps rapid diagnosis.
Jin, L; Feng, Y; Parry, R; Cui, A; Lu, Y
2007-11-01
A real-time polymerase chain reaction assay was initially developed in China to detect mumps genome. The primers and TaqMan-MGB probe were selected from regions of the hemagglutinin gene of mumps virus. The primers and probe for the real-time PCR were evaluated by both laboratories in China and in the UK using three different pieces of equipment, LightCycler (Roche), MJ DNA Engine Option 2 (BIO-RAD) and TaqMan (ABI Prism) on different samples. The reaction was performed with either a one-step (China) or two-step (UK) process. The sensitivity (10 copies) was estimated using a serial dilution of constructed mumps-plasmid DNA and a linear standard curve was obtained between 10 and 10(7) DNA copies/reaction, which can be used to quantify viral loads. The detection limit on cell culture-grown virus was approximately 2 pfu/ml with a two-step assay on TaqMan, which was equivalent to the sensitivity of the nested PCR routinely used in the UK. The specificity was proved by testing a range of respiratory viruses and several genotypes of mumps strains. The concentration of primers and probe is 22 pmol and 6.25 or 7 pmol respectively for a 25 microl reaction. The assay took 3 hr from viral RNA extraction to complete the detection using any of the three pieces of equipment. Three hundred forty-one (35 in China and 306 in the UK) clinical specimens were tested, the results showing that this real-time PCR assay is suitable for rapid and accurate detection of mumps virus RNA in various types of clinical specimens. (c) 2007 Wiley-Liss, Inc.
Nagy, Alexander; Černíková, Lenka; Vitásková, Eliška; Křivda, Vlastimil; Dán, Ádám; Dirbáková, Zuzana; Jiřincová, Helena; Procházka, Bohumír; Sedlák, Kamil; Havlíčková, Martina
2016-01-01
In the present work, we optimised and evaluated a qPCR system integrating 6-FAM (6-carboxyfluorescein)-labelled TaqMan probes and melting analysis using the SYTO 82 (S82) DNA binding dye in a single reaction. We investigated the influence of the S82 on various TaqMan and melting analysis parameters and defined its optimal concentration. In the next step, the method was evaluated in 36 different TaqMan assays with a total of 729 paired reactions using various DNA and RNA templates, including field specimens. In addition, the melting profiles of interest were correlated with the electrophoretic patterns. We proved that the S82 is fully compatible with the FAM-TaqMan system. Further, the advantages of this approach in routine diagnostic TaqMan qPCR were illustrated with practical examples. These included solving problems with flat or other atypical amplification curves or even false negativity as a result of probe binding failure. Our data clearly show that the integration of the TaqMan qPCR and melting analysis into a single assay provides an additional control option as well as the opportunity to perform more complex analyses, get more data from the reactions, and obtain analysis results with higher confidence. PMID:27031831
ERIC Educational Resources Information Center
Potterfield, James E.; And Others
This social studies unit includes a teaching guide, student text, study guide, teacher background material, and composite pretest/posttest covering archaeological methods, evolution, fossils and man, and development of culture during the prehistoric periods in the Old World. It is part of the Anthropology Curriculum Project and is designed for…
Exercise-induced hand tremor: a possible test for beta 2-adrenoceptor selectivity in man?
Abila, B; Wilson, J F; Marshall, R W; Richens, A
1986-01-01
The effects of intravenous doses of propranolol, sotalol, timolol, atenolol and placebo on exercise-induced tachycardia and exercise-induced increases in hand tremor were assessed in four healthy volunteers. All active drugs produced significant reductions in exercise-induced tachycardia. Exercise caused consistent significant increases in hand tremor which were blocked by the three non-cardioselective drugs but not by atenolol or placebo. The blockade of exercise-induced hand tremor is suggested as a possible test for the assessment of the selectivity of beta-adrenoceptor blockade in man. PMID:2874824
Study of Man-Machine Communications Systems for the Handicapped. Volume III. Final Report.
ERIC Educational Resources Information Center
Kafafian, Haig
The report describes a series of studies conducted to determine the extent to which severly handicapped students who were able to comprehend language and language structure but who were not able to write or type could communicate using various man-machine systems. Included among the systems tested were specialized electric typewriting machines, a…
21 CFR 514.111 - Refusal to approve an application.
Code of Federal Regulations, 2013 CFR
2013-04-01
... misleading in any particular; or (8) Such drug induces cancer when ingested by man or animal or, after appropriate tests for evaluation of the safety of such drug, induces cancer in man or animal, except that this... 21 Food and Drugs 6 2013-04-01 2013-04-01 false Refusal to approve an application. 514.111 Section...
21 CFR 514.111 - Refusal to approve an application.
Code of Federal Regulations, 2010 CFR
2010-04-01
... misleading in any particular; or (8) Such drug induces cancer when ingested by man or animal or, after appropriate tests for evaluation of the safety of such drug, induces cancer in man or animal, except that this... 21 Food and Drugs 6 2010-04-01 2010-04-01 false Refusal to approve an application. 514.111 Section...
21 CFR 514.111 - Refusal to approve an application.
Code of Federal Regulations, 2011 CFR
2011-04-01
... misleading in any particular; or (8) Such drug induces cancer when ingested by man or animal or, after appropriate tests for evaluation of the safety of such drug, induces cancer in man or animal, except that this... 21 Food and Drugs 6 2011-04-01 2011-04-01 false Refusal to approve an application. 514.111 Section...
21 CFR 514.111 - Refusal to approve an application.
Code of Federal Regulations, 2012 CFR
2012-04-01
... misleading in any particular; or (8) Such drug induces cancer when ingested by man or animal or, after appropriate tests for evaluation of the safety of such drug, induces cancer in man or animal, except that this... 21 Food and Drugs 6 2012-04-01 2012-04-01 false Refusal to approve an application. 514.111 Section...
21 CFR 514.111 - Refusal to approve an application.
Code of Federal Regulations, 2014 CFR
2014-04-01
... misleading in any particular; or (8) Such drug induces cancer when ingested by man or animal or, after appropriate tests for evaluation of the safety of such drug, induces cancer in man or animal, except that this... 21 Food and Drugs 6 2014-04-01 2014-04-01 false Refusal to approve an application. 514.111 Section...
The F-16 Onboard Oxygen Generating System: Performance Evaluation and Man Rating
1983-08-01
OXYGEN GENERATING , YSTEM: PERFORMANCE EVALUATION AND MAN RATING Thomas C. Horch , Captain, USAF Richard L. Miller, Ph.D. John B. Bomar, Jr...C. Horch , Capt, USAF; R. L. Miller, 8. CONTRACT OR GRANT NUMBER(i) Ph.D.; J. B. Bomar, Jr., Lt Col, IJSAF, BSC; J. B. Tedor, Maj, USAF, BSC; R. D...limitation (as of 1983); however, the information may no longer need protection since it is 14 years. At the time of its publication, Capt Thomas Horch
Czajkowski, Robert; van der Wolf, Jan M
2012-11-01
A Serratia plymuthica-specific TaqMan® assay was designed based on the consensus nucleotide sequence from the 3'- end of the luxS gene present in all S. plymuthica strains tested. The specificity of the assay was demonstrated by testing 21 Serratia spp. strains and 30 isolates belonging to various species that can potentially coexist with S. plymuthica in the same environment. Positive reactions in the TaqMan® assay were observed only for S. plymuthica isolates and not for other bacteria. The TaqMan® assay could detect down to 1.95 ng of S. plymuthica DNA, down to 5 bacterial cells per reaction (100 cfu ml(-1)) in vitro, down to 50 bacterial cells per reaction (1,000 cfu ml(-1)) in spiked potato root extracts and down to 5 bacterial cells per reaction (100 cfu ml(-1)) in spiked potato haulm extracts. We used this assay to quantify S. plymuthica A30 cells in potato and tomato haulms and roots grown from S. plymuthica A30-inoculated potato seed tubers and tomato seeds. The results were comparable with the spread-plating of plant extracts on a newly developed S. plymuthica A30 selective medium (CVTR2Arif). The TaqMan® assay can be used to quantify S. plymuthica isolates in different ecosystems and in complex substrates.
Liu, Jie; Ochieng, Caroline; Wiersma, Steve; Ströher, Ute; Towner, Jonathan S; Whitmer, Shannon; Nichol, Stuart T; Moore, Christopher C; Kersh, Gilbert J; Kato, Cecilia; Sexton, Christopher; Petersen, Jeannine; Massung, Robert; Hercik, Christine; Crump, John A; Kibiki, Gibson; Maro, Athanasia; Mujaga, Buliga; Gratz, Jean; Jacob, Shevin T; Banura, Patrick; Scheld, W Michael; Juma, Bonventure; Onyango, Clayton O; Montgomery, Joel M; Houpt, Eric; Fields, Barry
2016-01-01
Acute febrile illness (AFI) is associated with substantial morbidity and mortality worldwide, yet an etiologic agent is often not identified. Convalescent-phase serology is impractical, blood culture is slow, and many pathogens are fastidious or impossible to cultivate. We developed a real-time PCR-based TaqMan array card (TAC) that can test six to eight samples within 2.5 h from sample to results and can simultaneously detect 26 AFI-associated organisms, including 15 viruses (chikungunya, Crimean-Congo hemorrhagic fever [CCHF] virus, dengue, Ebola virus, Bundibugyo virus, Sudan virus, hantaviruses [Hantaan and Seoul], hepatitis E, Marburg, Nipah virus, o'nyong-nyong virus, Rift Valley fever virus, West Nile virus, and yellow fever virus), 8 bacteria (Bartonella spp., Brucella spp., Coxiella burnetii, Leptospira spp., Rickettsia spp., Salmonella enterica and Salmonella enterica serovar Typhi, and Yersinia pestis), and 3 protozoa (Leishmania spp., Plasmodium spp., and Trypanosoma brucei). Two extrinsic controls (phocine herpesvirus 1 and bacteriophage MS2) were included to ensure extraction and amplification efficiency. Analytical validation was performed on spiked specimens for linearity, intra-assay precision, interassay precision, limit of detection, and specificity. The performance of the card on clinical specimens was evaluated with 1,050 blood samples by comparison to the individual real-time PCR assays, and the TAC exhibited an overall 88% (278/315; 95% confidence interval [CI], 84% to 92%) sensitivity and a 99% (5,261/5,326, 98% to 99%) specificity. This TaqMan array card can be used in field settings as a rapid screen for outbreak investigation or for the surveillance of pathogens, including Ebola virus. Copyright © 2015, American Society for Microbiology. All Rights Reserved.
Saha, Ratul; Bestervelt, Lorelle L; Donofrio, Robert S
2012-02-01
Pseudomonas fluorescens ATCC 13525 is used as the challenge organism to evaluate the efficacy of the clean-in-place (CIP) process of food equipment (automatic ice-maker) as per NSF/ANSI Standard 12. Traditional culturing methodology is presently used to determine the concentration of the challenge organism, which takes 48 h to confirm the cell density. Storage of the challenge preparation in the refrigerator might alter the cell density as P. fluorescens is capable of growing at 4 °C. Also, background organism can grow on the Pseudomonas F agar (PFA) used for the recovery of P. fluorescens thus affecting the results of the test. Real-time TaqMan assay targeting the cpn60 gene was developed for the enumeration and the identification of P. fluorescens because of its specificity, accuracy, and shorter turnaround time. The TaqMan primer-probe pair developed using the Allele ID® 7.0 probe design software was highly specific and sensitive for the target organism. The sensitivity of the assay was 10 colony forming units (CFU)/mL. The assay was also successful in determining the concentration of the challenge preparation within 2 h. Based on these observations, TaqMan assay targeting the cpn60 gene can be efficiently used for strain level identification and enumeration of bacteria. Pseudomonas fluorescens ATCC 13525 is used as a challenge organism in the efficacy testing of clean-in-place process of food equipments. Currently, culturing technique is used for its identification and estimation, which is not only time-consuming but also prone to error. Real-time TaqMan assay is more specific, sensitive, and accurate along with a shorter turnaround time compared to culturing techniques, thereby increasing the overall quality of the testing methodology to evaluate the clean-in-place process critical for the food industry to protect public health and safety. © 2012 Institute of Food Technologists®
Perera, Piyumali K; Gasser, Robin B; Pulford, David J; Stevenson, Mark A; Firestone, Simon M; McFadden, Andrew M J; Jabbar, Abdul
2015-03-31
Oriental theileriosis is a tick-borne disease of bovines caused by the members of the Theileria orientalis complex. Recently, we developed a multiplexed tandem (MT) PCR to detect, differentiate and quantitate four genotypes (i.e., buffeli, chitose, ikeda and type 5) of T. orientalis. In this study, we used MT PCR to assess the prevalence and infection intensity of four T. orientalis genotypes in selected cattle herds that experienced oriental theileriosis outbreaks in New Zealand, and compared the sensitivities and specificities of MT PCR, PCR-high resolution melting (PCR-HRM) and a TaqMan qPCR. MT PCR, PCR-HRM analysis for T. orientalis and a TaqMan qPCR assay for ikeda genotype were employed to test 154 and 88 cattle blood samples from North (where oriental theileriosis outbreaks had occurred; designated as Group 1) and South (where no outbreaks had been reported; Group 2) Islands of New Zealand, respectively. Quantitative data from MT PCR assay were analyzed using generalized linear model and paired-sample t-test. The diagnostic specificity and sensitivity of the assays were estimated using a Bayesian latent class modeling approach. In Group 1, 99.4% (153/154) of cattle were test-positive for T. orientalis in both the MT PCR and PCR-HRM assays. The apparent prevalences of genotype ikeda in Group 1 were 87.6% (134/153) and 87.7% (135/154) using the MT PCR and Ikeda TaqMan qPCR assays, respectively. Using the MT PCR test, all four genotypes of T. orientalis were detected. The infection intensity estimated for genotype ikeda was significantly higher (P = 0.009) in severely anaemic cattle than in those without anaemia, and this intensity was significantly higher than that of buffeli (P < 0.001) in the former cattle. Bayesian latent class analysis showed that the diagnostic sensitivities (97.1-98.9%) and specificities (96.5-98.9%) of the three PCR assays were very comparable. The present findings show the advantages of using the MT PCR assay as a useful tool for in-depth epidemiological and transmission studies of T. orientalis worldwide.
Garbuglia, A R; Angeletti, C; Lauria, F N; Zaccaro, P; Cocca, A M; Pisciotta, M; Solmone, M; Capobianchi, M R
2007-12-01
We compared two commercial assays for HBV DNA quantitation, Versant HBV 3.0, System 340 (bDNA; Bayer Diagnostics) and COBAS AmpliPrep-COBAS TaqMan HBV Test (TaqMan; Roche Diagnostics). Analytical sensitivity, calculated on WHO International Standard, predicted 95% detection rate at 11.4 and 520.2IU/ml for TaqMan and bDNA, respectively. Specificity, established on 50 blood donor samples, was 100% and 84% for TaqMan and bDNA, respectively. When using clinical samples, HBV DNA was detected by TaqMan in 21/55 samples negative to bDNA. Mean values of HBV DNA obtained with bDNA were higher than those obtained with TaqMan (4.09log(10)+/-1.90 versus 3.39log(10)+/-2.41, p<0.001), and 24.4% of samples showed differences in viral load values >0.5log(10), without association with HBV genotype. There was a good correlation for HBV DNA concentrations measured by the two assays (r=0.94; p<0.001) within the overlapping range, and the distribution of results with respect to relevant clinical threshold recently confirmed (20,000 and 2000IU/ml) was similar. Approximately 50% of samples with low HBV DNA, appreciated by TaqMan but not by bDNA, were successfully sequenced in pol region, where drug resistance mutations are located.
Assessing Man’s Impact on Wetlands,
1980-12-01
AD-A94 652 ARMY MILITARY PERSONNEL CENTER ALEXANDRIA VA F/S 8/6 ASSESSZNG MAN’S IMPACT ON WE LANDS,(U) UNCLASSIFIED 0 GALLOWAY 1 A uhuhfuhfhumEIliE...EElliE mrhhmhhhhEEohE mmmmmmmmm Assessing Mns Impact on Wetlands By G.E. Galloway rpp fo f A.l - 5 UN RI pulcto N-RI7-3 D 1 i ILI ’!UNt’ Sea Grant...TITLE (and Subtitle) - - 5. TYPE OF REPORT & PERIOD COVERED /Assessing Man’s Impact on Wetlands December 1980 6. PERFORMING ORG. REPORT NUMBER 7- AU HOR
Ocular bacillary angiomatosis in an immunocompromised man.
Murray, Meltzer A; Zamecki, Katherine J; Paskowski, Joseph; Lelli, Gary J
2010-01-01
An immunocompromised man presented with an inflammatory eyelid lesion. Biopsy was performed; histopathology and special staining confirmed a diagnosis of bacillary angiomatosis. The man was treated with oral erythromycin, and the lesion resolved. The etiologic agents of bacillary angiomatosis are Bartonella henselae and Bartonella quintana, Gram-negative coccobacilli. The organisms stain positively with the Warthin-Starry silver stain. Lesions can be cutaneous or visceral and have been commonly described in immunocompromised patients. Histopathologic examination of lesions reveals angiogenesis and cellular proliferation. Bacillary angiomatosis can be treated with oral antibiotics.
Solovjev, V A
1987-09-01
Today, more than 20 years after the first in the world man's space walk, soviet cosmonautics gained large experience of extravehicular activity (EVA). Space suits of high reliability, onboard facilities for passing through the airlock, sets of special tools and technological rigging, as well as procedures for carrying out various EVA's were developed. In the course of the Salyut-7 space station orbital operation the EVA's have become regular. The author of the report as the participant of the EVA's considers the main steps of man activities in space and analyzes specific problems arised in performing such activities.
Use of Heritage Hardware on MPCV Exploration Flight Test One
NASA Technical Reports Server (NTRS)
Rains, George Edward; Cross, Cynthia D.
2011-01-01
Due to an aggressive schedule for the first orbital test flight of an unmanned Orion capsule, known as Exploration Flight Test One (EFT1), combined with severe programmatic funding constraints, an effort was made to identify heritage hardware, i.e., already existing, flight-certified components from previous manned space programs, which might be available for use on EFT1. With the end of the Space Shuttle Program, no current means exists to launch Multi Purpose Logistics Modules (MPLMs) to the International Space Station (ISS), and so the inventory of many flight-certified Shuttle and MPLM components are available for other purposes. Two of these items are the Shuttle Ground Support Equipment Heat Exchanger (GSE Hx) and the MPLM cabin Positive Pressure Relief Assembly (PPRA). In preparation for the utilization of these components by the Orion Program, analyses and testing of the hardware were performed. The PPRA had to be analyzed to determine its susceptibility to pyrotechnic shock, and vibration testing had to be performed, since those environments are predicted to be significantly more severe during an Orion mission than those the hardware was originally designed to accommodate. The GSE Hx had to be tested for performance with the Orion thermal working fluids, which are different from those used by the Space Shuttle. This paper summarizes the certification of the use of heritage hardware for EFT1.
Distributed medical services within the ATM-based Berlin regional test bed
NASA Astrophysics Data System (ADS)
Thiel, Andreas; Bernarding, Johannes; Krauss, Manfred; Schulz, Sandra; Tolxdorff, Thomas
1996-05-01
The ATM-based Metropolitan Area Network (MAN) of Berlin connects two university hospitals (Benjamin Franklin University Hospital and Charite) with the computer resources of the Technical University of Berlin (TUB). Distributed new medical services have been implemented and will be evaluated within the highspeed MAN of Berlin. The network with its data transmission rates of up to 155 Mbit/s renders these medical services externally available to practicing physicians. Resource and application sharing is demonstrated by the use of two software systems. The first software system is an interactive 3D reconstruction tool (3D- Medbild), based on a client-server mechanism. This structure allows the use of high- performance computers at the TUB from the low-level workstations in the hospitals. A second software system, RAMSES, utilizes a tissue database of Magnetic Resonance Images. For the remote control of the software, the developed applications use standards such as DICOM 3.0 and features of the World Wide Web. Data security concepts are being tested and integrated for the needs of the sensitive medical data. The highspeed network is the necessary prerequisite for the clinical evaluation of data in a joint teleconference. The transmission of digitized real-time sequences such as video and ultrasound and the interactive manipulation of data are made possible by Multi Media tools.
Solid electrolyte oxygen regeneration system
NASA Technical Reports Server (NTRS)
Shumar, J. W.; See, G. G.; Schubert, F. H.; Powell, J. D.
1976-01-01
A program to design, develop, fabricate and assemble a one-man, self-contained, solid electrolyte oxygen regeneration system (SX-1) incorporating solid electrolyte electrolyzer drums was completed. The SX-1 is a preprototype engineering model designed to produce 0.952 kg (2.1 lb)/day of breathable oxygen (O2) from the electrolysis of metabolic carbon dioxide (CO2) and water vapor. The CO2 supply rate was established based on the metabolic CO2 generation rate for one man of 0.998 kg (2.2 lb)/day. The water supply rate (0.254 kg (0.56 lb)/day) was designed to be sufficient to make up the difference between the 0.952 kg (2.1 lb)/day O2 generation specification and the O2 available through CO2 electrolysis, 0.726 kg (1.6 lb)/day. The SX-1 was successfully designed, fabricated and assembled. Design verification tests (DVT) or the CO Disproportionators, H2 separators, control instrumentation, monitor instrumentation, water feed mechanism were successfully completed. The erratic occurrence of electrolyzer drum leakage prevented the completion of the CO2 electrolyzer module and water electrolyzer module DVT's and also prevented the performance of SX-1 integrated testing. Further development work is required to improve the solid electrolyte cell high temperature seals.
NASA Astrophysics Data System (ADS)
Leewe, R.; Shahriari, Z.; Moallem, M.
2017-10-01
Control of the natural resonance frequency of an RF cavity is essential for accelerator structures due to their high cavity sensitivity to internal and external vibrations and the dependency of resonant frequency on temperature changes. Due to the relatively high radio frequencies involved (MHz to GHz), direct measurement of the resonant frequency for real-time control is not possible by using conventional microcontroller hardware. So far, all operational cavities are tuned using phase comparison techniques. The temperature dependent phase measurements render this technique labor and time intensive. To eliminate the phase measurement, reduce man hours and speed up cavity start up time, this paper presents a control theme that relies solely on the reflected power measurement. The control algorithm for the nonlinear system is developed through Lyapunov's method. The controller stabilizes the resonance frequency of the cavity using a nonlinear control algorithm in combination with a gradient estimation method. Experimental results of the proposed system on a test cavity show that the resonance frequency can be tuned to its optimum operating point while the start up time of a single cavity and the accompanied man hours are significantly decreased. A test result of the fully commissioned control system on one of TRIUMF's DTL tanks verifies its performance under real environmental conditions.
1982-01-01
McDornel Douglas performed an Evolutionary Space Platform Concept Study for the Marshall Space Flight Center in the early 1980's. The 10-month study was designed to define, evaluate, and compare approaches and concepts for evolving unmanned and manned capability platforms beyond the then current space platform concepts to an evolutionary goal of establishing a permanent-manned presence in space.
The role of man in flight experiment payload missions. Volume 2: Appendices
NASA Technical Reports Server (NTRS)
Malone, T. B.
1973-01-01
In the study to determine the role of man in Sortie Lab operations, a functional model of a generalized experiment system was developed. The results are presented of a requirements analysis which was conducted to identify performance requirements, information requirements, and interface requirements associated with each function in the model.
SKYLAB (SL)-3 - ASTRONAUT GARRIOTT, OWEN
1973-08-09
S73-32113 (9 Aug. 1973) --- Scientist-astronaut Owen K. Garriott, Skylab 3 science pilot, serves as test subject for the Skylab ?Human Vestibular Function? M131 Experiment, as seen in this photographic reproduction taken from a television transmission made by a color TV camera aboard the Skylab space station in Earth orbit. The objectives of the Skylab M131 experiment are to obtain data pertinent to establishing the validity of measurements of specific behavioral/physiological responses influenced by vestibular activity under one-g and zero-g conditions; to determine man?s adaptability to unusual vestibular conditions and predict habitability of future spacecraft conditions involving reduced gravity and Coriollis forces; and to measure the accuracy and variability in man?s judgment of spatial coordinates based on atypical gravity receptor cues and inadequate visual cues. Photo credit: NASA
ThOMAs: the other means of assessment.
Williams, Andrew N; Debelle, Geoffrey D; Davies, Paul; Barrett, Tim G
2005-02-01
We describe a pilot study to investigate whether drawing "Thomas the Tank Engine" could be as effective a measure of developmental progress as the Goodenough-Harris Draw A Man test against the ThOMAs test (The Other Means of Assessment), with internal validation. The study included 95 children aged between 3 and 11 years of age, including a subgroup of 13 children with registered special needs from community and general pediatric clinics within Birmingham, UK, as a means of validation. There was no significant evidence that ThOMAS was either culturally or sex biased. Using regression analysis, nine items were found to correlate highly with actual age, and their total score gave a correlation of 0.563 with age. Adding further items did not increase this. After being converted into age-standardized scores, ThOMAS was as sensitive and specific as the Draw A Man test, and more so above a defined age-standardized threshold. This pilot study suggests that drawing Thomas the Tank Engine would appear to be as sensitive and specific a means of identifying children with special needs as the Goodenough-Harris Draw A Man test. The relatively small sample size means that further research is necessary to further define the age standardizations and to refine the ThOMAs test.
Occurrence of $sup 137$Cs in the biosphere evaluated with environmental and metabolic studies
DOE Office of Scientific and Technical Information (OSTI.GOV)
Haesaenen, E.
This work forms a part of the fall-out studies carried out in the Department of Radiochemistry, University of Helsinki. Its main emphasis has been on the $gamma$-spectrometric determination of the $sup 137$Cs-levels and changes herein in different environmental samples and in man after the second nuclear testing period in 1961--1962. Special attention has been paid to the aquatic foodchains of $sup 137$Cs, to the foodchain reindeer-lichen-man, and to the biological half-life of $sup 137$Cs in man and in certain fish species. (auth)
NASA Astrophysics Data System (ADS)
Maksimov, A. I.
2011-06-01
Development of cosmonautics and preparation to the first manned space flights are briefly observed. Details of the development of the first Soviet intercontinental ballistic missile R-7, which served as a basis for creating Sputnik, Vostok, Voskhod, Molniya, and Soyuz launchers, are given. The contributions of the outstanding designers of space engineering, W. von Braun, S.P. Korolev, V.P. Glushko, and academician M.V. Keldysh, to the development of astronautics and first manned space missions are demonstrated. A list of test launches and manned flights of Vostok and Mercury spacecrafts and the basic characteristics of Vostok, Redstone, Atlas-D, Voskhod, and Soyuz launchers are presented.
NASA Technical Reports Server (NTRS)
Atwell, William; Koontz, Steve; Normand, Eugene
2012-01-01
Three twentieth century technological developments, 1) high altitude commercial and military aircraft; 2) manned and unmanned spacecraft; and 3) increasingly complex and sensitive solid state micro-electronics systems, have driven an ongoing evolution of basic cosmic ray science into a set of practical engineering tools needed to design, test, and verify the safety and reliability of modern complex technological systems. The effects of primary cosmic ray particles and secondary particle showers produced by nuclear reactions with the atmosphere, can determine the design and verification processes (as well as the total dollar cost) for manned and unmanned spacecraft avionics systems. Similar considerations apply to commercial and military aircraft operating at high latitudes and altitudes near the atmospheric Pfotzer maximum. Even ground based computational and controls systems can be negatively affected by secondary particle showers at the Earth s surface, especially if the net target area of the sensitive electronic system components is large. Finally, accumulation of both primary cosmic ray and secondary cosmic ray induced particle shower radiation dose is an important health and safety consideration for commercial or military air crews operating at high altitude/latitude and is also one of the most important factors presently limiting manned space flight operations beyond low-Earth orbit (LEO). In this paper we review the discovery of cosmic ray effects on the performance and reliability of microelectronic systems as well as human health and the development of the engineering and health science tools used to evaluate and mitigate cosmic ray effects in ground-based atmospheric flight, and space flight environments. Ground test methods applied to microelectronic components and systems are used in combinations with radiation transport and reaction codes to predict the performance of microelectronic systems in their operating environments. Similar radiation transport codes are used to evaluate possible human health effects of cosmic ray exposure, however, the health effects are based on worst-case analysis and extrapolation of a very limited human exposure data base combined with some limited experimental animal data. Finally, the limitations on human space operations beyond low-Earth orbit imposed by long term exposure to galactic cosmic rays are discussed.
Murphy, Helen R; Lee, Seulgi; da Silva, Alexandre J
2017-07-01
Cyclospora cayetanensis is a protozoan parasite that causes human diarrheal disease associated with the consumption of fresh produce or water contaminated with C. cayetanensis oocysts. In the United States, foodborne outbreaks of cyclosporiasis have been linked to various types of imported fresh produce, including cilantro and raspberries. An improved method was developed for identification of C. cayetanensis in produce at the U.S. Food and Drug Administration. The method relies on a 0.1% Alconox produce wash solution for efficient recovery of oocysts, a commercial kit for DNA template preparation, and an optimized TaqMan real-time PCR assay with an internal amplification control for molecular detection of the parasite. A single laboratory validation study was performed to assess the method's performance and compare the optimized TaqMan real-time PCR assay and a reference nested PCR assay by examining 128 samples. The samples consisted of 25 g of cilantro or 50 g of raspberries seeded with 0, 5, 10, or 200 C. cayetanensis oocysts. Detection rates for cilantro seeded with 5 and 10 oocysts were 50.0 and 87.5%, respectively, with the real-time PCR assay and 43.7 and 94.8%, respectively, with the nested PCR assay. Detection rates for raspberries seeded with 5 and 10 oocysts were 25.0 and 75.0%, respectively, with the real-time PCR assay and 18.8 and 68.8%, respectively, with the nested PCR assay. All unseeded samples were negative, and all samples seeded with 200 oocysts were positive. Detection rates using the two PCR methods were statistically similar, but the real-time PCR assay is less laborious and less prone to amplicon contamination and allows monitoring of amplification and analysis of results, making it more attractive to diagnostic testing laboratories. The improved sample preparation steps and the TaqMan real-time PCR assay provide a robust, streamlined, and rapid analytical procedure for surveillance, outbreak response, and regulatory testing of foods for detection of C. cayetanensis.
The Computerized Anatomical Man (CAM) model
NASA Technical Reports Server (NTRS)
Billings, M. P.; Yucker, W. R.
1973-01-01
A computerized anatomical man (CAM) model, representing the most detailed and anatomically correct geometrical model of the human body yet prepared, has been developed for use in analyzing radiation dose distribution in man. This model of a 50-percentile standing USAF man comprises some 1100 unique geometric surfaces and some 2450 solid regions. Internal body geometry such as organs, voids, bones, and bone marrow are explicitly modeled. A computer program called CAMERA has also been developed for performing analyses with the model. Such analyses include tracing rays through the CAM geometry, placing results on magnetic tape in various forms, collapsing areal density data from ray tracing information to areal density distributions, preparing cross section views, etc. Numerous computer drawn cross sections through the CAM model are presented.
NASA Astrophysics Data System (ADS)
Solvik, K.; Macedo, M.; Graesser, J.; Lathuilliere, M. J.
2017-12-01
Large-scale agriculture and cattle ranching in Brazil has driving the creation of tens of thousands of small stream impoundments to provide water for crops and livestock. These impoundments are a source of methane emissions and have significant impacts on stream temperature, connectivity, and water use over a large region. Due to their large numbers and small size, they are difficult to map using conventional methods. Here, we present a two-stage object-based supervised classification methodology for identifying man-made impoundments in Brazil. First, in Google Earth Engine pixels are classified as water or non-water using satellite data and HydroSHEDS products as predictors. Second, using Python's scikit-learn and scikit-image modules the water objects are classified as man-made or natural based on a variety of shape and spectral properties. Both classifications are performed by a random forest classifier. Training data is acquired by visually identifying impoundments and natural water bodies using high resolution satellite imagery from Google Earth.This methodology was applied to the state of Mato Grosso using a cloud-free mosaic of Sentinel 1 (10m resolution) radar and Sentinel 2 (10-20m) multispectral data acquired during the 2016 dry season. Independent test accuracy was estimated at 95% for the first stage and 93% for the second. We identified 54,294 man-made impoundments in Mato Grosso in 2016. The methodology is generalizable to other high resolution satellite data and has been tested on Landsat 5 and 8 imagery. Applying the same approach to Landsat 8 images (30 m), we identified 35,707 impoundments in the 2015 dry season. The difference in number is likely because the coarser-scale imagery fails to detect small (< 900 m2) objects. On-going work will apply this approach to satellite time series for the entire Amazon-Cerrado frontier, allowing us to track changes in the number, size, and distribution of man-made impoundments. Automated impoundment mapping over large areas may help with management of streams in agricultural landscapes in Brazil and other tropical regions.
Aerodynamics of high frequency flapping wings
NASA Astrophysics Data System (ADS)
Hu, Zheng; Roll, Jesse; Cheng, Bo; Deng, Xinyan
2010-11-01
We investigated the aerodynamic performance of high frequency flapping wings using a 2.5 gram robotic insect mechanism developed in our lab. The mechanism flaps up to 65Hz with a pair of man-made wing mounted with 10cm wingtip-to-wingtip span. The mean aerodynamic lift force was measured by a lever platform, and the flow velocity and vorticity were measured using a stereo DPIV system in the frontal, parasagittal, and horizontal planes. Both near field (leading edge vortex) and far field flow (induced flow) were measured with instantaneous and phase-averaged results. Systematic experiments were performed on the man-made wings, cicada and hawk moth wings due to their similar size, frequency and Reynolds number. For insect wings, we used both dry and freshly-cut wings. The aerodynamic force increase with flapping frequency and the man-made wing generates more than 4 grams of lift at 35Hz with 3 volt input. Here we present the experimental results and the major differences in their aerodynamic performances.
Outcomes of repeat catheter ablation using magnetic navigation or conventional ablation.
Akca, Ferdi; Theuns, Dominic A M J; Abkenari, Lara Dabiri; de Groot, Natasja M S; Jordaens, Luc; Szili-Torok, Tamas
2013-10-01
After initial catheter ablation, repeat procedures could be necessary. This study evaluates the efficacy of the magnetic navigation system (MNS) in repeat catheter ablation as compared with manual conventional techniques (MANs). The results of 163 repeat ablation procedures were analysed. Ablations were performed either using MNS (n = 84) or conventional manual ablation (n = 79). Procedures were divided into four groups based on the technique used during the initial and repeat ablation procedure: MAN-MAN (n = 66), MAN-MNS (n = 31), MNS-MNS (n = 53), and MNS-MAN (n = 13). Three subgroups were analysed: supraventricular tachycardias (SVTs, n = 68), atrial fibrillation (AF, n = 67), and ventricular tachycardias (VT, n = 28). Recurrences were assessed during 19 ± 11 months follow-up. Overall, repeat procedures using MNS were successful in 89.0% as compared with 96.2% in the MAN group (P = ns). The overall recurrence rate was significantly lower using MNS (25.0 vs. 41.4%, P = 0.045). Acute success and recurrence rates for the MAN-MAN, MAN-MNS, MNS-MNS, and MNS-MAN groups were comparable. For the SVT subgroup a higher acute success rate was achieved using MAN (87.9 vs. 100.0%, P = 0.049). The use of MNS for SVT is associated with longer procedure times (205 ± 82 vs. 172 ± 69 min, P = 0.040). For AF procedure and fluoroscopy times were longer (257 ± 72 vs. 185 ± 64, P = 0.001; 59.5 ± 19.3 vs. 41.1 ± 18.3 min, P < 0.001). Less fluoroscopy was used for MNS-guided VT procedures (22.8 ± 14.7 vs. 41.2 ± 10.9, P = 0.011). Our data suggest that overall MNS is comparable with MAN in acute success after repeat catheter ablation. However, MNS is related to fewer recurrences as compared with MAN.
Design and engineering of a man-made diffusive electron-transport protein
Fry, Bryan A.; Solomon, Lee A.; Dutton, P. Leslie
2016-01-01
Maquettes are man-made cofactor-binding oxidoreductases designed from first principles with minimal reference to natural protein sequences. Here we focus on water-soluble maquettes designed and engineered to perform diffusive electron transport of the kind typically carried out by cytochromes, ferredoxins and flavodoxins and other small proteins in photosynthetic and respiratory energy conversion and oxido-reductive metabolism. Our designs were tested by analysis of electron transfer between heme maquettes and the well-known natural electron transporter, cytochrome c. Electron-transfer kinetics were measured from seconds to milliseconds by stopped-flow, while sub-millisecond resolution was achieved through laser photolysis of the carbon monoxide maquette heme complex. These measurements demonstrate electron transfer from the maquette to cytochrome c, reproducing the timescales and charge complementarity modulation observed in natural systems. The ionic strength dependence of inter-protein electron transfer from 9.7 × 106 M−1s−1 to 1.2 × 109 M−1s−1 follows a simple Debye-Hückel model for attraction between +8 net charged oxidized cytochrome c and −19 net charged heme maquette, with no indication of significant protein dipole moment steering. Successfully recreating essential components of energy conversion and downstream metabolism in man-made proteins holds promise for in vivo clinical intervention and for the production of fuel or other industrial products. PMID:26423266
Fernández, F; D'Alessio, C; Fanchiotti, S; Parodi, A J
1998-10-15
A key element in the quality control of glycoprotein folding is the UDP-Glc:glycoprotein glucosyltransferase (GT), which in cell-free assays exclusively glucosylates misfolded glycoproteins. In order to test if such a protein conformation is a sufficient condition for in vivo glucosylation of all N-linked oligosaccharides by GT, a Schizosaccharomyces pombe double mutant (gls2/alg6) was constructed. With this mutant, Man9GlcNAc2 is transferred to proteins and no removal of glucose units added by GT occurs as it lacks glucosidase II. The same proportion of glucosylated (Glc1Man9GlcNAc2) and unglucosylated (Man9GlcNAc2 and Man8GlcNAc2) endoplasmic reticulum (ER)-specific compounds was produced when cells were pre-incubated for 10, 20 or 30 min and further incubated with [14C]glucose for 10 min at 28 degrees C with or without 5 mM dithiothreitol (DTT), thus indicating not only that DTT did not affect protein glucosylation but also that no increased glucosylation of glycoproteins occurred in the presence of the drug. Monitoring Golgi-specific modifications of oligosaccharides after pulse-chase experiments performed in the presence or absence of 5 mM DTT showed that exit of the bulk of glycoproteins synthesized from the ER and thence their proper folding had been prevented by the drug. Cells pulse-chase labeled at 37 degrees C in the absence of DTT also yielded glucosylated and unglucosylated protein-linked oligosaccharides without Golgi-specific modifications. It was concluded that a misfolded protein conformation is not a sufficient condition for in vivo glucosylation of all N-linked oligosaccharides by GT.
Hatzakis, Angelos; Papachristou, Helen; Nair, Sangeetha J; Fortunko, Jacqueline; Foote, Tracy; Kim, HeeCheol; Peling, Tashi L; Worlock, Andrew J
2016-10-21
Quantitation of HIV-RNA is critically important for diagnosis, prognosis, treatment, monitoring and assessment of infectivity in HIV-1 infection. The objective of this study was to assess performance characteristics of the Aptima HIV-1 Quant Dx assay (Aptima), a new transcription mediated amplification (TMA), fully integrated and automated assay from Hologic Inc., San Diego, CA, USA. The analytical sensitivity, analytical specificity, precision and detection of HIV-1 subtypes were tested based on commercially available international standards or panels. A selected group of 244 anti-HIV-1 (+) plasma samples was used for comparison with Roche COBAS Ampliprep/COBAS TaqMan HIV- 1 test v2.0 (Roche CAP/CTM), (Roche Molecular Systems, Pleasanton, CA). The 50 and 95 % limit of detection were estimated at 4.9 (95 % CI 3.9-5.7) and 17.6 (15.2-21.2) IU/mL respectively. The specificity was found 99.83 (99.06-99.97) %. The standard deviations and coefficient of variations for panels with 50 and 100 copies/mL (1.7 and 2 log copies/mL) were 0.14 log copies/mL (8.67 %CV) and 0.18 log copies/mL (9.91 %CV) respectively. The detection rate for Aptima and Roche assays was 220/244 (90.2 %) and 217/244 (88.9 %) respectively. The Aptima assay is a sensitive, specific, precise and accurate test for measuring HIV-1 viral loads and for the detection of HIV-1 infections.
Usefulness of in-house PCR methods for hepatitis B virus DNA detection.
Portilho, Moyra Machado; Baptista, Marcia Leite; da Silva, Messias; de Sousa, Paulo Sérgio Fonseca; Lewis-Ximenez, Lia Laura; Lampe, Elisabeth; Villar, Livia Melo
2015-10-01
The aim of the present study was to evaluate the performance of three in-house PCR techniques for HBV DNA detection and compare it with commercial quantitative methods to evaluate the usefulness of in-house methods for HBV diagnosis. Three panels of HBsAg reactive sera samples were evaluated: (i) 50 samples were examined using three methods for in-house qualitative PCR and the Cobas Amplicor HBV Monitor Assay; (ii) 87 samples were assayed using in-house semi-nested PCR and the Cobas TaqMan HBV test; (iii) 11 serial samples obtained from 2 HBV-infected individuals were assayed using the Cobas Amplicor HBV test and semi-nested PCR. In panel I, HBV DNA was detected in 44 samples using the Cobas Amplicor HBV test, 42 samples using semi-nested PCR (90% concordance with Cobas Amplicor), 22 samples using PCR for the core gene (63.6% concordance) and 29 samples using single-round PCR for the pre-S/S gene (75% concordance). In panel II, HBV DNA was quantified in 78 of the 87 HBsAg reactive samples using Cobas TaqMan but 52 samples using semi-nested PCR (67.8% concordance). HBV DNA was detected in serial samples until the 17th and 26th week after first donation using in-house semi-nested PCR and the Cobas Amplicor HBV test, respectively. In-house semi-nested PCR presented adequate concordance with commercial methods as an alternative method for HBV molecular diagnosis in low-resource settings. Copyright © 2015 Elsevier B.V. All rights reserved.
Can Intelligence Be Estimated From Drawings Of A Man?
ERIC Educational Resources Information Center
Reisman, John M.; Yamokoski, Tom
1973-01-01
The Goodenough-Harris Draw-A-Man Test (DAM) and either the WISC or Stanford-Binet (S-B) were administered to 158 normal'' children. Discrepancy scores between the DAM and the S-B or WISC indicated that the DAM IQ tends to be below, at times considerably, IQs obtained from individual scales. Moreover, the DAM seemed to be virtually useless in…
ERIC Educational Resources Information Center
Almquist, Alan J.; Cronin, John E.
This is one of several study guides on contemporary problems produced by the American Association for the Advancement of Science with support of the National Science Foundation. This guide focuses on the origin of man. Part I, The Biochemical Evidence for Human Evolution, contains four sections: (1) Introduction; (2) Macromolecular Data; (3)…
Crew Training - Apollo 9 (Alt. Chamber) - KSC
1968-01-01
S68-55272 (15 Nov. 1968) --- The Apollo 9 prime crew is seen inside the Apollo 9 spacecraft in the Kennedy Space Center's Manned Spacecraft Operations Building during manned altitude chamber test activity. Left to right, are astronauts James A. McDivitt, commander; David R. Scott, command module pilot; and Russell L. Schweickart (out of view to far right), lunar module pilot.
Combination of an electrolytic pretreatment unit with secondary water reclamation processes
NASA Technical Reports Server (NTRS)
Wells, G. W.; Bonura, M. S.
1973-01-01
The design and fabrication of a flight concept prototype electrolytic pretreatment unit (EPU) and of a contractor-furnished air evaporation unit (AEU) are described. The integrated EPU and AEU potable water recovery system is referred to as the Electrovap and is capable of processing the urine and flush water of a six-man crew. Results of a five-day performance verification test of the Electrovap system are presented and plans are included for the extended testing of the Electrovap to produce data applicable to the combination of electrolytic pretreatment with most final potable water recovery systems. Plans are also presented for a program to define the design requirements for combining the electrolytic pretreatment unit with a reverse osmosis final processing unit.
The Association Between MCT1 T1470A Polymorphism and Power-Oriented Athletic Performance.
Kikuchi, N; Fuku, N; Matsumoto, R; Matsumoto, S; Murakami, H; Miyachi, M; Nakazato, K
2017-01-01
The purpose of this study was to investigate the effects of the MCT1 T1470A polymorphism (rs1049434) on power-oriented performance and lactate concentration during or after cycling sprints in Japanese wrestlers. Participants (199 wrestlers and 649 controls) were genotyped for the MCT1 T1470A genotype (rs1049434) using the TaqMan ® Assay. All wrestlers were international (n=77) or national (n=122) level athletes. Among them, 46 wrestlers performed 2 anaerobic performance tests, a 30-s Wingate Anaerobic test (WAnT) and a series of 10 maximal effort 10-s sprints on a cycle ergometer. Blood lactate levels were measured before, during, and after the tests. In the A-allele recessive model (AA vs. TA+TT), the frequency of the AA genotype was significantly higher in all wrestlers than in controls (p=0.037). Wrestlers with AA genotype had lower blood lactate concentrations than those with TA+TT genotype at 10 min after the WAnT and following the 5 th and the final set of repeated cycling sprints (p<0.05). The AA genotype of the MCT1 T1470A polymorphism is over-represented in wrestlers compared with controls and is associated with lower blood lactate concentrations after 30-s WAnT and during intermittent sprint tests in Japanese wrestlers. © Georg Thieme Verlag KG Stuttgart · New York.
Who was that masked man? Conjoint representations of intrinsic motions with actor appearance.
Kersten, Alan W; Earles, Julie L; Negri, Leehe
2018-09-01
Motion plays an important role in recognising animate creatures. This research supports a distinction between intrinsic and extrinsic motions in their relationship to identifying information about the characters performing the motions. Participants viewed events involving costumed human characters. Intrinsic motions involved relative movements of a character's body parts, whereas extrinsic motions involved movements with respect to external landmarks. Participants were later tested for recognition of the motions and who had performed them. The critical test items involved familiar characters performing motions that had previously been performed by other characters. Participants falsely recognised extrinsic conjunction items, in which characters followed the paths of other characters, more often than intrinsic conjunction items, in which characters moved in the manner of other characters. In contrast, participants falsely recognised new extrinsic motions less often than new intrinsic motions, suggesting that they remembered extrinsic motions but had difficulty remembering who had performed them. Modelling of receiver operating characteristics indicated that participants discriminated old items from intrinsic conjunction items via familiarity, consistent with conjoint representations of intrinsic motion and identity information. In contrast, participants used recollection to distinguish old items from extrinsic conjunction items, consistent with separate but associated representations of extrinsic motion and identity information.
Yang, Lixue; Chen, Kean
2015-11-01
To improve the design of underwater target recognition systems based on auditory perception, this study compared human listeners with automatic classifiers. Performances measures and strategies in three discrimination experiments, including discriminations between man-made and natural targets, between ships and submarines, and among three types of ships, were used. In the experiments, the subjects were asked to assign a score to each sound based on how confident they were about the category to which it belonged, and logistic regression, which represents linear discriminative models, also completed three similar tasks by utilizing many auditory features. The results indicated that the performances of logistic regression improved as the ratio between inter- and intra-class differences became larger, whereas the performances of the human subjects were limited by their unfamiliarity with the targets. Logistic regression performed better than the human subjects in all tasks but the discrimination between man-made and natural targets, and the strategies employed by excellent human subjects were similar to that of logistic regression. Logistic regression and several human subjects demonstrated similar performances when discriminating man-made and natural targets, but in this case, their strategies were not similar. An appropriate fusion of their strategies led to further improvement in recognition accuracy.
Garner, Will; White, Kirsten; Szwarcberg, Javier; McCallister, Scott; Zhong, Lijie; Wulfsohn, Mike
2016-01-01
Background. The COBAS AMPLICOR HIV-1 MONITOR Test, version 1.5 (Amplicor) has been replaced with the COBAS AmpliPrep/COBAS TaqMan HIV-1 Test, version 2.0 (TaqMan 2.0), a real-time polymerase chain reaction human immunodeficiency virus type 1 (HIV-1) assay with higher sensitivity and broader dynamic range. HIV-1 RNA values at the 50 copies/mL cutoff drive major patient management decisions and clinical study outcomes. Methods. A total of 2217 samples were collected from 1922 HIV-1–infected subjects taking antiretroviral therapy for at least 48 weeks and had at least 2 consecutive samples with HIV-1 RNA <50 copies/mL by Amplicor from 7 recent clinical trials. HIV-1 RNA results were obtained from the Amplicor and TaqMan 2.0 assays in parallel by a reference laboratory. Results. The overall concordance between assay results was 96% at the cutoff of 50 copies/mL. However, statistically significant discordance at the 50 copies/mL cutoff was found between the assays for 3.9% of samples (n = 87). By TaqMan 2.0, virologic failure defined as HIV-1 RNA ≥50 copies/mL was reported for 2.8% more samples than Amplicor. Of these 87 samples, 68 samples fell within the predicted range of assay variability. Retesting of HIV-1 RNA by TaqMan 2.0 confirmed the discordance in only 28 of the 87 samples. Conclusions. The TaqMan 2.0 assay reports fewer subjects below the clinical endpoint of HIV-1 RNA <50 copies/mL in HIV clinical trials than the Amplicor assay. This difference must be considered when assessing disease progression, designing clinical trials, and comparisons with historical trials that used the Amplicor assay. PMID:26689956
Extravehicular activities guidelines and design criteria
NASA Technical Reports Server (NTRS)
Brown, N. E.; Dashner, T. R.; Hayes, B. C.
1973-01-01
A listing of astronaut EVA support systems and equipment, and the physical, operational, and performance characteristics of each major system are presented. An overview of the major ground based support operations necessary in the development and verification of orbital EVA systems is included. The performance and biomedical characteristics of man in the orbital EV environment are discussed. Major factors affecting astronaut EV work performance are identified and delineated as they relate to EV support systems design. Data concerning the medical and physiological aspects of spaceflight on man are included. The document concludes with an extensive bibliography, and a series of appendices which expand on some of the information presented in the main body.
29 CFR 1620.17 - Jobs requiring equal responsibility in performance.
Code of Federal Regulations, 2010 CFR
2010-07-01
... justify a wage rate differential between the man's and woman's job if the equal pay provisions otherwise... the higher rate to both men and women who are called upon from time to time to assume such supervisory... either a man or a woman) is authorized and required to determine whether to accept payment for purchases...
29 CFR 1620.17 - Jobs requiring equal responsibility in performance.
Code of Federal Regulations, 2012 CFR
2012-07-01
... justify a wage rate differential between the man's and woman's job if the equal pay provisions otherwise... the higher rate to both men and women who are called upon from time to time to assume such supervisory... either a man or a woman) is authorized and required to determine whether to accept payment for purchases...
29 CFR 780.316 - Thirteen week provision.
Code of Federal Regulations, 2010 CFR
2010-07-01
... consisting of seven consecutive 24-hour periods during which the employee worked at least 1 “man-day.” Section 3(u) of the Act defines a man-day as “any day during which an employee performs any agricultural... 13(a)(6)(C) (as well as section 3(e)(2)) comports with the traditional definition of week used in...
Evaluation of Magnetostrictive Shunt Damper Performance Using Iron (Fe)-Gallium (Ga) Alloy
2013-09-01
Technol. 2003, 11 (4), 482– 494 3. Manning, K. V.; Watanabe, K.; Drake, A. E.; Wright, A. Eddy Current. in AccessScience , ©McGraw-Hill Education...2012, http://www.accessscience.com. 4. Manning, K. V. Lenz’s Law in AccessScience , ©McGraw-Hill Education, 2012, http://www.accessscience.com 5
NASA Technical Reports Server (NTRS)
1972-01-01
Guidelines for the selection of equipment to be used for manned spacecraft in order to assure a five year maintenance-free service life were developed. A special study was conducted to determine the adequacy of the procedures used to determine the quality and effectiveness of various components. The subjects examined are: (1) temperature cycling for acceptance of electronic assemblies; (2) accelerated testing techniques; (3) electronic part screening techniques; (4) electronic part derating practices; (5) vibration life extension of printed circuit board assemblies; and (6) tolerance funnelling and test requirements.
ERIC Educational Resources Information Center
Austin, Carol E.; And Others
The social studies unit includes a teaching guide, teacher background material, student text, study guide, and composite pretest/posttest. Subject matter focuses on archaeological methods, history of man in America, and the Hopi Indians in the past and present. The unit is part of the Anthropology Curriculum Project and is designed to be used in…
Antarctica as a testing ground for manned missions to the Moon and Mars
NASA Astrophysics Data System (ADS)
Demidov, N. E.; Lukin, V. V.
2017-03-01
This paper is concerned with the study of expedition activity in Antarctica as a part of the search for useful analogies and solutions which can be taken into account in planning manned missions to the Moon and Mars. The following is considered: natural analogies, human factors, station facilities, means of transportation, scientific programs, safety issues, and historical and political analogies. A rationalization is given for the idea of creating a testing ground in Antarctica (stations Vostok, Novolazarevskaya, Jetty Oasis) for ground-based simulation of functioning of a lunar and Martian base.
Skylab - Skylab Medical Evaluation Activities Test (SMEAT) - MSC
1972-06-16
S72-41853 (15 June 1972) --- Two members of the three-man Skylab Medical Experiment Altitude Test (SMEAT) crew, that will spend up to 56 days in the Crew Systems Division's 20-foot altitude chamber at the Manned Spacecraft Center (MSC) beginning in mid-July, go over a menu in the food preparation area. Seated at the simulated wardroom food table is astronaut Karol J. Bobko, SMEAT pilot, and standing is astronaut Robert L. Crippen, SMEAT commander. Dr. William E. Thornton, SMEAT science pilot, the third crew member is not shown in this view. Photo credit: NASA
SKYLAB (SL) MEDICAL EXPERIMENT ALTITUDE TEST (SMEAT) - MSC
1972-06-16
S72-41858 (15 June 1972) --- Astronauts Robert L. Crippen, left, Skylab Medical Experiment Altitude Test (SMEAT) crew commander, and Dr. William E. Thornton, SMEAT science pilot, stand at the cabinet containing off duty recreation equipment. They are two members of a three-man SMEAT crew who will spend up to 56 days in the Crew Systems Division's 20-foot altitude chamber at the NASA Manned Spacecraft Center (MSC) beginning in mid-July to obtain medical data and evaluate medical experiment equipment for Skylab. Astronaut Karol J. Bobko, SMEAT pilot, the third crew member is not shown in this view. Photo credit: NASA
Cascade Distillation Subsystem Development: Progress Toward a Distillation Comparison Test
NASA Technical Reports Server (NTRS)
Callahan, M. R.; Lubman, A.; Pickering, Karen D.
2009-01-01
Recovery of potable water from wastewater is essential for the success of long-duration manned missions to the Moon and Mars. Honeywell International and a team from NASA Johnson Space Center (JSC) are developing a wastewater processing subsystem that is based on centrifugal vacuum distillation. The wastewater processor, referred to as the Cascade Distillation Subsystem (CDS), utilizes an innovative and efficient multistage thermodynamic process to produce purified water. The rotary centrifugal design of the system also provides gas/liquid phase separation and liquid transport under microgravity conditions. A five-stage subsystem unit has been designed, built, delivered and integrated into the NASA JSC Advanced Water Recovery Systems Development Facility for performance testing. A major test objective of the project is to demonstrate the advancement of the CDS technology from the breadboard level to a subsystem level unit. An initial round of CDS performance testing was completed in fiscal year (FY) 2008. Based on FY08 testing, the system is now in development to support an Exploration Life Support (ELS) Project distillation comparison test expected to begin in early 2009. As part of the project objectives planned for FY09, the system will be reconfigured to support the ELS comparison test. The CDS will then be challenged with a series of human-gene-rated waste streams representative of those anticipated for a lunar outpost. This paper provides a description of the CDS technology, a status of the current project activities, and data on the system s performance to date.
Maritz, Jean; Preiser, Wolfgang; van Zyl, Gert U
2012-02-01
As antibody testing cannot confirm HIV-1 infection in children less than 18 months of age, diagnosis in these children depends on nucleic acid testing. The COBAS(®) AmpliPrep/COBAS(®) TaqMan(®) (CAP/CTM, Roche(®) Molecular Systems, Inc., Branchburg, NJ) HIV-1 Qualitative test is a total nucleic acid real-time PCR assay utilising whole EDTA blood or dried blood spots (DBS), which recently replaced the Roche(®) AMPLICOR(®) DNA test v1.5 (Amplicor) as the diagnostic HIV PCR assay in many South African laboratories. For the Amplicor assay, stringent diagnostic criteria were previously formulated for the local population, and a comparison reported the CAP/CTM's sensitivity at 99.7% and specificity at 100% for both sample types compared to these Amplicor criteria. To validate the assay prior to introduction in our laboratory and to define stringent diagnostic cut-off criteria. Whole EDTA blood samples from patients younger than 18 months sent for routine HIV-1 diagnosis were tested by Amplicor, and positive results were confirmed from DBS. CAP/CTM assays were subsequently performed from DBS. The CAP/CTM had a sensitivity of 98.8% and a specificity of 97.1%, but a positive predictive value (PPV) of only 78.7% compared to the Amplicor assay. Samples positive by CAP/CTM but negative by Amplicor displayed poor amplification curves compared to concordant positive samples. Upon re-testing those with sufficient material available by CAP/CTM, all showed negative results. The decreased PPV may either be due to false positive CAP/CTM results, or increased sensitivity compared to the Amplicor assay. Criteria were formulated for defining presumed false-positive results. Copyright © 2011 Elsevier B.V. All rights reserved.
NASA Technical Reports Server (NTRS)
Redmond, M.; Polk, J. D.; Hamilton, D.; Schuette, M.; Guttromson, J.; Guess, T.; Smith, B.
2005-01-01
The NASA Manned Space Program uses an electrocardiograph (ECG) system to monitor astronauts during extravehicular activity (EVA). This ECG system, called the Operational Bioinstrumentation System (OBS), was developed during the Apollo era. Throughout the Shuttle program these electrodes experienced failures during several EVAs performed from the Space Shuttle and International Space Station (ISS) airlocks. An attempt during Shuttle Flight STS-109 to replace the old electrodes with new commercial off-the-shelf (COTS) disposable electrodes proved unsuccessful. One assumption for failure of the STS-109 COTS electrodes was the expansion of trapped gases under the foam electrode pad, causing the electrode to be displaced from the skin. Given that our current electrodes provide insufficient reliability, a number of COTS ECG electrodes were tested at the NASA Altitude Manned Chamber Test Facility. Methods: OBS disposable electrodes were tested on human test subjects in an altitude chamber simulating an Extravehicular Mobility Unit (EMU) operating pressure of 4.3 psia with the following goals: (1) to confirm the root cause of the flight certified, disposable electrode failure during flight STS-109. (2) to identify an adequate COTS replacement electrode and determine if further modifications to the electrodes are required. (3) to evaluate the adhesion of each disposable electrode without preparation of the skin with isopropyl alcohol. Results: There were several electrodes that failed the pressure testing at 4.3psia, including the electrodes used during flight STS-109. Two electrodes functioned well throughout all testing and were selected for further testing in an EMU at altitude. A vent hole placed in all electrodes was also tested as a possible solution to prevent gas expansion from causing electrode failures. Conclusions: Two failure modes were identified: (1) foam-based porous electrodes entrapped air bubbles under the pad (2) poor adhesion caused some electrodes to fail
Orion FSW V and V and Kedalion Engineering Lab Insight
NASA Technical Reports Server (NTRS)
Mangieri, Mark L.
2010-01-01
NASA, along with its prime Orion contractor and its subcontractor s are adapting an avionics system paradigm borrowed from the manned commercial aircraft industry for use in manned space flight systems. Integrated Modular Avionics (IMA) techniques have been proven as a robust avionics solution for manned commercial aircraft (B737/777/787, MD 10/90). This presentation will outline current approaches to adapt IMA, along with its heritage FSW V&V paradigms, into NASA's manned space flight program for Orion. NASA's Kedalion engineering analysis lab is on the forefront of validating many of these contemporary IMA based techniques. Kedalion has already validated many of the proposed Orion FSW V&V paradigms using Orion's precursory Flight Test Article (FTA) Pad Abort 1 (PA-1) program. The Kedalion lab will evolve its architectures, tools, and techniques in parallel with the evolving Orion program.
Waterfield, Thomas; Patenall, Bethany; McKenna, James; Fairley, Derek
2017-12-01
Despite successful vaccination programmes meningococcal disease (MD) remains the leading infectious cause of septicaemia and death in children in the UK and Ireland. 1,2 The early diagnosis of MD significantly improves outcomes with reduced morbidity and mortality. 1,2 The early stages of MD are often indistinguishable from a simple viral illness making an early positive diagnosis of MD difficult. 1 Hibergene have developed a commercially available bedside Loop-mediated isothermal AMPlification PCR (LAMP-MD) test that is a highly sensitive 0.89 (95%CI 0.72-0.96) and specific 1.0 (95%CI 0.97-1.0) for identifying children with invasive MD (4) (figure 1).emermed;34/12/A895-a/F1F1F1Figure 1 AIMS: The aims of this RCEM funded study were:Assess the ease of use and suitability for the EDDetermine the time taken to perform the testIndependently verify LAMP-MD performance against TaqMan quantitative PCR. The LAMP-MD was assessed for practicality and ease of use within the ED including an assessment of training needs, footprint and health and safety requirements.For verification of the Hibergene LAMP-MD analyser and assay we used dry nasopharyngeal swabs sent for viral screening. Additional verification was undertaken using N. meningitidis genomic DNA spiked over a range of concentrations. This included serotypes A, B, C, W, X and Y and a dilution series to determine the limit of detection. All samples were then analysed using real time TaqMan qPCR. The LAMP-MD analyser was easy to use and could be accommodated in the EDThe mean time for detection of Meningococcal DNA was 14.01 minDetection of meningococcal serogroups A, B, C, W, X and Z was confirmedThe detection limit for dry nasopharyngeal swabs was below 2 genomic copies per µlNo non-specific amplification was observed in 17 randomly selected negative clinical swabsThe LAMP-MD assay was 100% sensitive and specific relative to real-time TaqMAN PCR. LAMP-MD is a practical, rapid point of care test that can reliably detect all Meningococcal serotypes in less than 15 min.Funding has been secured to perform a PERUKI supported study to investigate the potential for LAMP-MD in the diagnosis of meningococcal disease in children. Meningitis Research Foundation. Meningococcal Meningitis and Septicaemia Guidance Notes 2014.Ó Maoldomhnaigh, et al. Invasive meningococcal disease in children in Ireland . PMID: 27566800.NICE. Management of petechial rash .Bourke TW, et al. Diagnostic accuracy of loop-mediated isothermal amplification as a near-patient test for meningococcal disease in children . PMID: 25728843. © 2017, Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://group.bmj.com/group/rights-licensing/permissions.
Use of Heritage Hardware on Orion MPCV Exploration Flight Test One
NASA Technical Reports Server (NTRS)
Rains, George Edward; Cross, Cynthia D.
2012-01-01
Due to an aggressive schedule for the first space flight of an unmanned Orion capsule, currently known as Exploration Flight Test One (EFT1), combined with severe programmatic funding constraints, an effort was made within the Orion Program to identify heritage hardware, i.e., already existing, flight-certified components from previous manned space programs, which might be available for use on EFT1. With the end of the Space Shuttle Program, no current means exists to launch Multi-Purpose Logistics Modules (MPLMs) to the International Space Station (ISS), and so the inventory of many flight-certified Shuttle and MPLM components are available for other purposes. Two of these items are the MPLM cabin Positive Pressure Relief Assembly (PPRA), and the Shuttle Ground Support Equipment Heat Exchanger (GSE HX). In preparation for the utilization of these components by the Orion Program, analyses and testing of the hardware were performed. The PPRA had to be analyzed to determine its susceptibility to pyrotechnic shock, and vibration testing had to be performed, since those environments are predicted to be more severe during an Orion mission than those the hardware was originally designed to accommodate. The GSE HX had to be tested for performance with the Orion thermal working fluids, which are different from those used by the Space Shuttle. This paper summarizes the activities required in order to utilize heritage hardware for EFT1.
Fidler, Sarah; Lewis, Heather; Meyerowitz, Jodi; Kuldanek, Kristin; Thornhill, John; Muir, David; Bonnissent, Alice; Timson, Georgina; Frater, John
2017-10-20
There is a global need for HIV viral load point-of-care (PoC) assays to monitor patients receiving antiretroviral therapy. UNICORN was the first study of an off-label protocol using whole blood finger-prick samples tested with and without a simple three minute spin using a clinic-room microcentrifuge. Two PoC assays were evaluated in 40 HIV-positive participants, 20 with detectable and 20 with undetectable plasma viral load (pVL) (<20 copies/ml). Using 100 µl finger-prick blood samples, the Cepheid Xpert HIV-1 Viral Load and HIV-1 Qual cartridges were compared with laboratory pVL assessment (TaqMan, Roche). For participants with undetectable viraemia by TaqMan, there was poor concordance without centrifugation with the TaqMan platform with only 40% 'undetectable' using Xpert VL and 25% 'not detected' using the Qual assay. After a 3 minute spin, 100% of samples were undetectable using either assay, showing full concordance with the TaqMan assay. Defining a lower limit of detection of 1000 copies/ml when including a spin, there was 100% concordance with the TaqMan platform with strong correlation (rho 0.95 and 0.94; p < 0.0001 for both assays). When including a simple microcentrifugation step, finger-prick PoC testing was a quick and accurate approach for assessing HIV viraemia, with excellent concordance with validated laboratory approaches.
Hydroshear Simulation Lab Test 2
Bauer, Steve
2014-08-01
This data file is for test 2. In this test a sample of granite with a pre cut (man made fracture) is confined, heated and differential stress is applied. max temperature in this this system development test is 95C. test details on the spreadsheets--note thta there are 2 spreadsheets
NASA Technical Reports Server (NTRS)
Reynolds, R. C.; Ruck, G. T.
1983-01-01
Observations using NORAD radar showed that man made debris exceeds the natural environment for large objects. For short times (a few days to a few weeks) after solid rocket motor (SRM) firings in LEO, man made debris in the microparticle size range also appears to exceed the meteoroid environment. The properties of the debris population between these size regimes is currently unknown as there has been no detector system able to perform the required observations. The alternatives for obtaining data on this currently unobserved segment of the population are assessed.
EDEM2 initiates mammalian glycoprotein ERAD by catalyzing the first mannose trimming step
Ninagawa, Satoshi; Okada, Tetsuya; Sumitomo, Yoshiki; Kamiya, Yukiko; Kato, Koichi; Horimoto, Satoshi; Ishikawa, Tokiro; Takeda, Shunichi; Sakuma, Tetsushi; Yamamoto, Takashi
2014-01-01
Glycoproteins misfolded in the endoplasmic reticulum (ER) are subjected to ER-associated glycoprotein degradation (gpERAD) in which Htm1-mediated mannose trimming from the oligosaccharide Man8GlcNAc2 to Man7GlcNAc2 is the rate-limiting step in yeast. In contrast, the roles of the three Htm1 homologues (EDEM1/2/3) in mammalian gpERAD have remained elusive, with a key controversy being whether EDEMs function as mannosidases or as lectins. We therefore conducted transcription activator-like effector nuclease–mediated gene knockout analysis in human cell line and found that all endogenous EDEMs possess mannosidase activity. Mannose trimming from Man8GlcNAc2 to Man7GlcNAc2 is performed mainly by EDEM3 and to a lesser extent by EDEM1. Most surprisingly, the upstream mannose trimming from Man9GlcNAc2 to Man8GlcNAc2 is conducted mainly by EDEM2, which was previously considered to lack enzymatic activity. Based on the presence of two rate-limiting steps in mammalian gpERAD, we propose that mammalian cells double check gpERAD substrates before destruction by evolving EDEM2, a novel-type Htm1 homologue that catalyzes the first mannose trimming step from Man9GlcNAc2. PMID:25092655
Integrated Vehicle Ground Vibration Testing of Manned Spacecraft: Historical Precedent
NASA Technical Reports Server (NTRS)
Lemke, Paul R.; Tuma, Margaret L.; Askins, Bruce R.
2008-01-01
For the first time in nearly 30 years, NASA is developing a new manned space flight launch system. The Ares I will carry crew and cargo to not only the International Space Station, but onward for the future exploration of the Moon and Mars. The Ares I control system and structural designs use complex computer models for their development. An Integrated Vehicle Ground Vibration Test (IVGVT) will validate the efficacy of these computer models. The IVGVT will reduce the technical risk of unexpected conditions that could place the vehicle or crew in jeopardy. The Ares Project Office's Flight and Integrated Test Office commissioned a study to determine how historical programs, such as Saturn and Space Shuttle, validated the structural dynamics of an integrated flight vehicle. The study methodology was to examine the historical record and seek out members of the engineering community who recall the development of historic manned launch vehicles. These records and interviews provided insight into the best practices and lessons learned from these historic development programs. The information that was gathered allowed the creation of timelines of the historic development programs. The timelines trace the programs from the development of test articles through test preparation, test operations, and test data reduction efforts. These timelines also demonstrate how the historical tests fit within their overall vehicle development programs. Finally, the study was able to quantify approximate staffing levels during historic development programs. Using this study, the Flight and Integrated Test Office was able to evaluate the Ares I Integrated Vehicle Ground Vibration Test schedule and workforce budgets in light of the historical precedents to determine if the test had schedule or cost risks associated with it.
Space station needs, attributes, and architectural options. Volume 1. Executive summary
NASA Technical Reports Server (NTRS)
Pritchard, E. B.
1983-01-01
The initial space station should be manned, placed in 28.5 deg orbit, and provide substantial economic, performance, and social benefits. The most beneficial space station capabilities include: a space test facility; a transport harbor; satellite servicing and assembly; and an observatory. A space industrial park could be added once further development effort validates the cost and expanding commercial market for space processed materials. The potential accrued gross mission model benefit derived from these capabilities is $5.9B without the industrial park, and $9.3B with it. An unclassified overview of all phases of the study is presented.
NASA Technical Reports Server (NTRS)
1972-01-01
A long life assurance program for the development of design, process, test, and application guidelines for achieving reliable spacecraft hardware was conducted. The study approach consisted of a review of technical data performed concurrently with a survey of the aerospace industry. The data reviewed included design and operating characteristics, failure histories and solutions, and similar documents. The topics covered by the guidelines are reported. It is concluded that long life hardware is achieved through meticulous attention to many details and no simple set of rules can suffice.
Impaired glucose utilization in man during acute exposure to environmental heat.
Tatár, P; Vigas, M; Jurcovicová, J; Jezová, D; Strec, V; Palát, M
1985-12-01
In 6 healthy males the oral glucose tolerance test (OGTT) was performed after the administration of 100 g glucose during the hyperthermic Finnish sauna bath (85 degrees C) of 30 min duration. The lowered insulin response (P less than 0.001) to glucose challenge during heating and the subsequent prolonged hyperglycemia (P less than 0.001) after heating were observed, when compared to OGTT under thermoneutral conditions (23 degrees C). It is suggested that the heat-induced decrease in visceral blood flow and stimulation of sympathoadrenomedullary and pituitary activity may be responsible for this effect.
Biorhythms and space experiments with nonhuman primates
NASA Technical Reports Server (NTRS)
Winget, C. M.
1977-01-01
Man's response to exposure to spaceflight and weightlessness is expressed in physiological adjustments which involve his health and ability to function. The amplitude and periodicity of fluctuations in biological processes affect various functions and responses to provocative stimuli. Primates and other species are subjected to tests to determine the consequences of an altered biorhythm on work and performance, emotional stability, biomedical evaluation in space, the ability to cope with the unexpected, and susceptibility to infection, toxicity, radiation, drugs, and stress. Factors in the environment or operational setup which can change the physiological baseline must be determined and controlled.
1971-11-01
The Apollo Telescope Mount (ATM), designed and developed by the Marshall Space Flight Center, was one of four major components comprising the Skylab (1973-1979). The ATM housed the first manned scientific telescope in space. This photograph shows the ATM rigged for altitude and space simulation tests at the Space Environment Simulation Laboratory of the Manned Spacecraft Center (MSC). The MSC was renamed the Johnson Space Center (JSC) in early 1973.
Development of task network models of human performance in microgravity
NASA Technical Reports Server (NTRS)
Diaz, Manuel F.; Adam, Susan
1992-01-01
This paper discusses the utility of task-network modeling for quantifying human performance variability in microgravity. The data are gathered for: (1) improving current methodologies for assessing human performance and workload in the operational space environment; (2) developing tools for assessing alternative system designs; and (3) developing an integrated set of methodologies for the evaluation of performance degradation during extended duration spaceflight. The evaluation entailed an analysis of the Remote Manipulator System payload-grapple task performed on many shuttle missions. Task-network modeling can be used as a tool for assessing and enhancing human performance in man-machine systems, particularly for modeling long-duration manned spaceflight. Task-network modeling can be directed toward improving system efficiency by increasing the understanding of basic capabilities of the human component in the system and the factors that influence these capabilities.
The Proceedings of the Skylab Life Sciences Symposium, volume 2
NASA Technical Reports Server (NTRS)
Johnston, R. S.; Dietlein, L. F.
1974-01-01
The three manned Skylab missions resulted in biomedical experiment data in the areas of neurophysiology, musculoskeletal physiology, biochemistry, hematology, cytology, cardiovascular and respiratory metabolic functions: as well as detailed test objectives involving crew health and environment procedures. Major emphasis was placed on results from the last mission, Skylab 4, which covered 84 days of in-flight data collection. Many new norms were defined for normal man living and operating in a unique environment. While man is quite adaptable to this unique environment, many of the changes observed in Skylab require additional research for future flights lasting very long periods of time such as a Mars mission requiring 18 months.
Use of IPsec by Manned Space Missions
NASA Technical Reports Server (NTRS)
Pajevski, Michael J.
2009-01-01
NASA's Constellation Program is developing its next generation manned space systems for missions to the International Space Station (ISS) and the Moon. The Program is embarking on a path towards standards based Internet Protocol (IP) networking for space systems communication. The IP based communications will be paired with industry standard security mechanisms such as Internet Protocol Security (IPsec) to ensure the integrity of information exchanges and prevent unauthorized release of sensitive information in-transit. IPsec has been tested in simulations on the ground and on at least one Earth orbiting satellite, but the technology is still unproven in manned space mission situations and significant obstacles remain.
The Proceedings of the Skylab Life Sciences Symposium, Volume 1
NASA Technical Reports Server (NTRS)
Johnston, R. S.; Dietlein, L. F.
1974-01-01
The three manned Skylab missions resulted in biomedical experiment data in the areas of neurophysiology, musculoskeletal physiology, biochemistry, hematology, cytology, cardiovascular and respiratory metabolic functions: as well as detailed test objectives involving crew health and environment procedures. Major emphasis was placed on results from the last mission, Skylab 4, which covered 84 days of in-flight data collection. Many new norms were defined for normal man living and operating in a unique environment. While man is quite adaptable to this unique environment, many of the changes observed in Skylab require additional research for future flights lasting very long periods of time such as a Mars mission requiring 18 months.
Imaging of neuro-cognitive performance in extreme Environments—A (p)review
NASA Astrophysics Data System (ADS)
Schneider, Stefan; Bubeev, Juri A.; Choukèr, Alexander; Morukov, Boris; Johannes, Bernd; Strüder, Heiko K.
2012-12-01
Living in extreme environments is accompanied by a number of stressors, which can be classified either as physiological stressors (e.g. microgravity, missing sunlight) or psychological stressors (e.g. confinement). From earth bound studies a negative impact of stress on mental health and cognitive performance is well known and both factors might impair mission success and mission safety during longer inhabitation of space. Accordingly there is the need to identify adequate countermeasures. Nevertheless causal research of neuro-cognitive impairments in space remains speculative due to missing possibilities of brain imaging. Furthermore the reliability of current psychological tests used to assess and monitor cognitive performance in extreme environments seems to be vulnerable due to a lack of compliance. With on-going plans of international space agencies to send people to moon and/or mars, this manuscript aims to summarize and review research attempts of the past two decades and to identify methodological shortcomings. Finally, following the guideline that research has no legacy for its own but must serve the self-concept and well-being of man, this manuscript presents a number of recommendations to enhance future neuro-cognitive research in extreme environments. A deeper insight into neuro-cognitive coherence is not only desirable to understand the effects of stress on mental health, which seems to be a major issue for our current society, and to develop adequate countermeasures but will also help to maintain and improve mission success and mission safety in manned space flight.
Refurbishment of one-person regenerative air revitalization system
NASA Technical Reports Server (NTRS)
Powell, Ferolyn T.
1989-01-01
Regenerative processes for the revitalization of spacecraft atmospheres and reclamation of waste waters are essential for making long-term manned space missions a reality. Processes studied include: static feed water electrolysis for oxygen generation, Bosch carbon dioxide reduction, electrochemical carbon dioxide concentration, vapor compression distillation water recovery, and iodine monitoring. The objectives were to: provide engineering support to Marshall Space Flight Center personnel throughout all phases of the test program, e.g., planning through data analysis; fabricate, test, and deliver to Marshall Space Flight Center an electrochemical carbon dioxide module and test stand; fabricate and deliver an iodine monitor; evaluate the electrochemical carbon dioxide concentrator subsystem configuration and its ability to ensure safe utilization of hydrogen gas; evaluate techniques for recovering oxygen from a product oxygen and carbon dioxide stream; and evaluate the performance of an electrochemical carbon dioxide concentrator module to operate without hydrogen as a method of safe haven operation. Each of the tasks were related in that all focused on providing a better understanding of the function, operation, and performance of developmental pieces of environmental control and life support system hardware.
Molecular implementation of simple logic programs.
Ran, Tom; Kaplan, Shai; Shapiro, Ehud
2009-10-01
Autonomous programmable computing devices made of biomolecules could interact with a biological environment and be used in future biological and medical applications. Biomolecular implementations of finite automata and logic gates have already been developed. Here, we report an autonomous programmable molecular system based on the manipulation of DNA strands that is capable of performing simple logical deductions. Using molecular representations of facts such as Man(Socrates) and rules such as Mortal(X) <-- Man(X) (Every Man is Mortal), the system can answer molecular queries such as Mortal(Socrates)? (Is Socrates Mortal?) and Mortal(X)? (Who is Mortal?). This biomolecular computing system compares favourably with previous approaches in terms of expressive power, performance and precision. A compiler translates facts, rules and queries into their molecular representations and subsequently operates a robotic system that assembles the logical deductions and delivers the result. This prototype is the first simple programming language with a molecular-scale implementation.
Jönsson, A; Arvebo, E; Schantz, B
1988-01-01
Experiments with an anthropomorphic dummy for blast research demonstrated that pressures recorded in the lung model of the dummy could be correlated to primary air blast effects on the lungs of experimental animals. The results presented here were obtained with a dummy of the type mentioned above, but with the lung model modified to improve geometric similarity to man. Blast experiments were performed in a shock tube, and impact experiments in a special impact machine. Experiments with nonpenetrating missiles were performed with small-caliber firearms and the dummy protected by body armor. Severity indices derived from the blast experiments were related to established criteria for primary lung injury in man. Impacts delivered in the impact machine and by nonpenetrating missiles are compared. Relationships between severity of impact based on experiments with animals and primary lung injury in man are discussed.
Saletu, B; Grünberger, J
1984-01-01
Changes in human brain function and mental performance under hypoxic hypoxidosis as well as after intravenous injection of aniracetam - a new potentially nootropic 2-pyrrolidinone derivative - were investigated in a double-blind placebo-controlled study utilizing computer-assisted spectral analysis of the EEG and psychometric tests. Hypoxic hypoxidosis was induced by a fixed gas combination of 11.2% O2 and 88.8% N2, which was inhaled under normobaric conditions by 10 male healthy volunteers. The following substances were injected intravenously at weekly intervals according to a latin square design: placebo, 10 mg and 100 mg aniracetam and the solvent under hypoxic conditions as well as placebo under normoxic conditions. Spectral analysis of the EEG recorded under hypoxia demonstrated neurophysiological alterations indicative of a deterioration in vigilance, which was also reflected by a deterioration in psychomotor activity and mnestic performance in the psychometric tests. Aniracetam i.v. attenuated the hypoxia-induced deterioration of brain function and mental performance, thus exhibiting protective properties against hypoxia in man. The usefulness of the hypoxia model in the screening of antihypoxidotic compounds is discussed.
A Status Report on the Parachute Development for NASA's Next Manned Spacecraft
NASA Technical Reports Server (NTRS)
Sinclair, Robert
2008-01-01
NASA has determined that the parachute portion of the Landing System for the Crew Exploration Vehicle (CEV) will be Government Furnished Equipment (GFE). The Earth Landing System has been designated CEV Parachute Assembly System (CPAS). Thus a program team was developed consisting of NASA Johnson Space Center (JSC) and Jacobs Engineering through their Engineering and Science Contract Group (ESCG). Following a rigorous competitive phase, Airborne Systems North America was selected to provide the parachute design, testing and manufacturing role to support this team. The development program has begun with some early flight testing of a Generation 1 parachute system. Future testing will continue to refine the design and complete a qualification phase prior to manned flight of the spacecraft. The program team will also support early spacecraft system testing, including a Pad Abort Flight Test in the Fall of 2008
2014-01-01
Background The Amberg-Schwandorf Algorithm for Primary Triage (ASAV) is a novel primary triage concept specifically for physician manned emergency medical services (EMS) systems. In this study, we determined the diagnostic reliability and the time requirements of ASAV triage. Methods Seven hundred eighty triage runs performed by 76 trained EMS providers of varying professional qualification were included into the study. Patients were simulated using human dummies with written vital signs sheets. Triage results were compared to a standard solution, which was developed in a modified Delphi procedure. Test performance parameters (e.g. sensitivity, specificity, likelihood ratios (LR), under-triage, and over-triage) were calculated. Time measurements comprised the complete triage and tagging process and included the time span for walking to the subsequent patient. Results were compared to those published for mSTaRT. Additionally, a subgroup analysis was performed for employment status (career/volunteer), team qualification, and previous triage training. Results For red patients, ASAV sensitivity was 87%, specificity 91%, positive LR 9.7, negative LR 0.139, over-triage 6%, and under-triage 10%. There were no significant differences related to mSTaRT. Per patient, ASAV triage required a mean of 35.4 sec (75th percentile 46 sec, 90th percentile 58 sec). Volunteers needed slightly more time to perform triage than EMS professionals. Previous mSTaRT training of the provider reduced under-triage significantly. There were significant differences in time requirements for triage depending on the expected triage category. Conclusions The ASAV is a specific concept for primary triage in physician governed EMS systems. It may detect red patients reliably. The test performance criteria are comparable to that of mSTaRT, whereas ASAV triage might be accomplished slightly faster. From the data, there was no evidence for a clinically significant reliability difference between typical staffing of mobile intensive care units, patient transport ambulances, or disaster response volunteers. Up to now, there is no clinical validation of either triage concept. Therefore, reality based evaluation studies are needed. PMID:25214310
Volynets, Valentina; Reichold, Astrid; Bárdos, Gyöngyi; Rings, Andreas; Bleich, André; Bischoff, Stephan C
2016-03-01
Intestinal permeability is thought to be of major relevance for digestive and nutrition-related diseases, and therefore has been studied in numerous mouse models of disease. However, it is unclear which tools are the preferable ones, and how normal values should be defined. To compare different in vivo permeability tests in healthy mice of commonly used genetic backgrounds. We assessed the intestinal barrier in male and female C57BL/6J and BALB/cJ mice of different ages, using four orally administered permeability markers, FITC-dextran 4000 (FITC-D4000) and ovalbumin (OVA) measured in plasma, and polyethylene glycol (PEG) and lactulose/mannitol (Lac/Man) measured in urine, and by assessing lipopolysaccharide (LPS) in portal vein plasma. After gavage, FITC-D4000, OVA, Lac/Man, and PEG400, but not PEG4000, were detectable in plasma or urine. Female mice tended to have a higher permeability according to the FITC-D4000, OVA, and PEG400 tests, but the Lac/Man ratio was higher in males. No significant differences between the two mouse strains of young and old mice were observed except for mannitol recovery, which was higher in BALB/cJ mice compared to C57BL/6J mice (p < 0.05). Virtually no LPS was detected in healthy mice. For all markers, normal values have been defined based on 5th-95th percentile ranges of our data. Selected oral permeability tests, such as FITC-D4000, OVA, PEG400, and Lac/Man, as well as LPS measurements in portal vein plasma, could be suitable for the evaluation of the intestinal barrier in mice, if used in a standardized way.
DANTi: Detect and Avoid iN The Cockpit
NASA Technical Reports Server (NTRS)
Chamberlain, James; Consiglio, Maria; Munoz, Cesar
2017-01-01
Mid-air collision risk continues to be a concern for manned aircraft operations, especially near busy non-towered airports. The use of Detect and Avoid (DAA) technologies and draft standards developed for unmanned aircraft systems (UAS), either alone or in combination with other collision avoidance technologies, may be useful in mitigating this collision risk for manned aircraft. This paper describes a NASA research effort known as DANTi (DAA iN The Cockpit), including the initial development of the concept of use, a software prototype, and results from initial flight tests conducted with this prototype. The prototype used a single Automatic Dependent Surveillance - Broadcast (ADS-B) traffic sensor and the own aircraft's position, track, heading and air data information, along with NASA-developed DAA software to display traffic alerts and maneuver guidance to manned aircraft pilots on a portable tablet device. Initial flight tests with the prototype showed a successful DANTi proof-of-concept, but also demonstrated that the traffic separation parameter set specified in the RTCA SC-228 Phase I DAA MOPS may generate excessive false alerts during traffic pattern operations. Several parameter sets with smaller separation values were also tested in flight, one of which yielded more timely alerts for the maneuvers tested. Results from this study may further inform future DANTi efforts as well as Phase II DAA MOPS development.
Space suit glove design with advanced metacarpal phalangeal joints and robotic hand evaluation.
Southern, Theodore; Roberts, Dustyn P; Moiseev, Nikolay; Ross, Amy; Kim, Joo H
2013-06-01
One area of space suits that is ripe for innovation is the glove. Existing models allow for some fine motor control, but the power grip--the act of grasping a bar--is cumbersome due to high torque requirements at the knuckle or metacarpal phalangeal joint (MCP). This area in particular is also a major source of complaints of pain and injury as reported by astronauts. This paper explores a novel fabrication and patterning technique that allows for more freedom of movement and less pain at this crucial joint in the manned space suit glove. The improvements are evaluated through unmanned testing, manned testing while depressurized in a vacuum glove box, and pressurized testing with a robotic hand. MCP joint flex score improved from 6 to 6.75 (out of 10) in the final glove relative to the baseline glove, and torque required for flexion decreased an average of 17% across all fingers. Qualitative assessments during unpressurized and depressurized manned testing also indicated the final glove was more comfortable than the baseline glove. The quantitative results from both human subject questionnaires and robotic torque evaluation suggest that the final iteration of the glove design enables flexion at the MCP joint with less torque and more comfort than the baseline glove.
Rapid Detection of the Chlamydiaceae and Other Families in the Order Chlamydiales: Three PCR Tests
Everett, Karin D. E.; Hornung, Linda J.; Andersen, Arthur A.
1999-01-01
Few identification methods will rapidly or specifically detect all bacteria in the order Chlamydiales, family Chlamydiaceae. In this study, three PCR tests based on sequence data from over 48 chlamydial strains were developed for identification of these bacteria. Two tests exclusively recognized the Chlamydiaceae: a multiplex test targeting the ompA gene and the rRNA intergenic spacer and a TaqMan test targeting the 23S ribosomal DNA. The multiplex test was able to detect as few as 200 inclusion-forming units (IFU), while the TaqMan test could detect 2 IFU. The amplicons produced in these tests ranged from 132 to 320 bp in length. The third test, targeting the 23S rRNA gene, produced a 600-bp amplicon from strains belonging to several families in the order Chlamydiales. Direct sequence analysis of this amplicon has facilitated the identification of new chlamydial strains. These three tests permit ready identification of chlamydiae for diagnostic and epidemiologic study. The specificity of these tests indicates that they might also be used to identify chlamydiae without culture or isolation. PMID:9986815
NASA Technical Reports Server (NTRS)
Olree, H. D.
1974-01-01
Training programs necessary for the development of optimal strength during prolonged manned space flight were examined, and exercises performed on the Super Mini Gym Skylab 2 were compared with similar exercises on the Universal Gym and calisthenics. Cardiopulmonary gains were found negligible but all training groups exhibited good gains in strength.
Definition of technology development missions for early space station satellite servicing, volume 1
NASA Technical Reports Server (NTRS)
1983-01-01
The testbed role of an early manned space station in the context of a satellite servicing evolutionary development and flight demonstration technology plan which results in a satellite servicing operational capability is defined. A satellite servicing technology development mission (a set of missions) to be performed on an early manned space station is conceptually defined.
Does the speaker's voice quality influence children's performance on a language comprehension test?
Lyberg-Åhlander, Viveka; Haake, Magnus; Brännström, Jonas; Schötz, Susanne; Sahlén, Birgitta
2015-02-01
A small number of studies have explored children's perception of speakers' voice quality and its possible influence on language comprehension. The aim of this explorative study was to investigate the relationship between the examiner's voice quality, the child's performance on a digital version of a language comprehension test, the Test for Reception of Grammar (TROG-2), and two measures of cognitive functioning. The participants were (n = 86) mainstreamed 8-year old children with typical language development. Two groups of children (n = 41/45) were presented with the TROG-2 through recordings of one female speaker: one group was presented with a typical voice and the other with a simulated dysphonic voice. Significant associations were found between executive functioning and language comprehension. The results also showed that children listening to the dysphonic voice achieved significantly lower scores for more difficult sentences ("the man but not the horse jumps") and used more self-corrections on simpler sentences ("the girl is sitting"). Findings suggest that a dysphonic speaker's voice may force the child to allocate capacity to the processing of the voice signal at the expense of comprehension. The findings have implications for clinical and research settings where standardized language tests are used.
Belotserkovsky, Harel; Berger, Yael; Shahar, Ron; Wolf, Shmuel
2007-12-01
Endo-beta-mannanase is one of the key enzymes involved in the hydrolysis of the mannan-rich cell walls of tomato (Solanum lycopersicon) seeds. Two isoforms of endo-beta-mannanase have been characterized in tomato seeds: LeMAN2 is active in the micropylar area prior to germination and LeMAN1 is active after germination in all endosperm cells surrounding the cotyledons. To explore whether general mannanase activity in the endosperm cap is sufficient to promote germination, the gene encoding LeMAN3 was inserted into transgenic tomato plants under the control of a CaMV-35S promoter. Expression of LeMAN3 was evident in the endosperm cap and in the lateral endosperm of the transgenic seeds 10 min after imbibition. An activity test indicated increased activity of endo-beta-mannanase in the transgenic lines relative to the control line in all seed parts, during the first 20 h of imbibition. However, overexpression of LeMAN3 in transgenic seeds inhibited seed germination at both optimal and suboptimal temperatures. Detailed RT-PCR analyses revealed the transcription patterns of the genes encoding the various mannanase isoforms, and indicated a delay in LeMAN2 transcription in the endosperm cap of the transgenic seeds. Interestingly, tissue-print assays indicated similar mannanase activity in the micropylar areas for both transgenic and control seeds. These results indicate that overexpression of active endo-beta-mannanase in the endosperm cap is not sufficient to enable hydrolysis of the cell walls or to promote germination of tomato seeds. Cell-wall hydrolysis in these endosperm cells is under tight control and requires the specific activity of LeMAN2.
Akca, Ferdi; Schwagten, Bruno; Theuns, Dominic A J; Takens, Marieke; Musters, Paul; Szili-Torok, Tamas
2013-12-01
Ablation of atrioventricular nodal re-entrant tachycardia (AVNRT) is a highly effective procedure both with radiofrequency (RF) and cryoenergy (CE). Conventionally, it requires several diagnostic catheters and hospital admission. This study assessed the safety and efficacy of a highly simplified approach using the magnetic navigation system (MNS) compared to CE and manual RF ablation (MAN). In the MNS group a single magnetic-guided quadripolar catheter was inserted through the internal jugular vein to perform ablation. In the CE group cryomapping preceded ablation and for MAN procedures conventional ablation was performed. The following parameters were analysed: success- and recurrence rate, procedure-, fluoroscopy- and total application time. In total 69 eligible patients were treated with MNS (n = 26), CE (n = 25) and MAN (n = 16). The success rates were 100%, 100% and 94%, respectively (p = ns). The mean procedural time was 83 +/- 25 min for MNS, 117 +/- 47 min for CE and 117 +/- 55 min for MAN (P < 0.01). Total radiation time was significantly lower for MNS [0.0 min (IQR 0.0-0.0)] compared to CE [15.1 min (IQR 9.1-23.8), P < 0.001] and MAN [17.5 min (IQR 7.0-31.3), P < 0.001]. The total application time was comparable for both RF groups: 357 +/- 315 s (MNS) vs 204 +/- 177 s (MAN) (P = 0.14). No major adverse events occurred. After 3 months follow-up similar PR intervals were recorded for all patients. During a follow-up of 26 +/- 5 months recurrence rates were 3.8%, 4.0% and 6.3%, respectively, for each group. The MNS-guided single-catheter approach is a feasible and safe technique for the treatment of patients with typical AVNRT.
Vozmediano, Valvanera; Ortega, Ignacio; Lukas, John C; Gonzalo, Ana; Rodriguez, Monica; Lucero, Maria Luisa
2014-03-01
Modern pharmacometrics can integrate and leverage all prior proprietary and public knowledge. Such methods can be used to scale across species or comparators, perform clinical trial simulation across alternative designs, confirm hypothesis and potentially reduce development burden, time and costs. Crucial yet typically lacking in integration is the pre-clinical stage. Prediction of PK in man, using in vitro and in vivo studies in different animal species, is increasingly well theorized but could still find wider application in drug development. The aim of the present work was to explore methods for bridging pharmacokinetic knowledge from animal species (i.v. and p.o.) and man (p.o.) into i.v. in man using the antihistamine drug bilastine as example. A model, predictive of i.v. PK in man, was developed on data from two pre-clinical species (rat and dog) and p.o. in man bilastine trials performed earlier. In the knowledge application stage, two different approaches were used to predict human plasma concentration after i.v. of bilastine: allometry (several scaling methods) and a semi-physiological method. Both approaches led to successful predictions of key i.v. PK parameters of bilastine in man. The predictive i.v. PK model was validated using later data from a clinical study of i.v. bilastine. Introduction of such knowledge in development permits proper leveraging of all emergent knowledge as well as quantification-based exploration of PK scenario, e.g. in special populations (pediatrics, renal insufficiency, comedication). In addition, the methods permit reduction or elimination and certainly optimization of learning trials, particularly those concerning alternative off-label administration routes.
Shu, Zunpeng; Yang, Yanni; Xing, Na; Wang, Yi; Wang, Qiuhong; Kuang, Haixue
2018-02-01
A purified polysaccharide, designated CALB-4, was acquired from Fructus aurantii that is the traditional edible/medicina plant in China. The present study was performed to characterize the CALB-4 and to evaluate its immunomodulatory activities on human peripheral blood mononuclear cells (PBMCs). The structure of CALB-4 was characterized by partial acid hydrolysis, periodate oxidation, Smith degradation, and methylation analysis combined with gas chromatography-mass spectrometry (GC-MS), Infrared Spectroscopy (IR) and scanning electron microscopy (SEM). The results indicated that CALB-4 was elucidated as a pectic polysaccharide and its main chain is composed of Man, Gal UA and Gal, interspersed with Ara, Rha, Man and Gal. Furthermore, immunological tests showed that CALB-4 exhibits the immunoenhancement effects. The mechanism for this action might be attributed to the increase of the cytoplasmic concentration of pro-IL-1 via the up-regulation of several mitogen-activated protein kinases (MAPKs) and the nuclear translocation of p65. This study clarified that CALB-4 could be as an efficacious biological response modifier in immunotherapy. Copyright © 2018. Published by Elsevier B.V.
NASA Astrophysics Data System (ADS)
Barati, Reza
2017-07-01
Perumal et al. (2017) compared the performances of the variable parameter McCarthy-Muskingum (VPMM) model of Perumal and Price (2013) and the nonlinear Muskingum (NLM) model of Gill (1978) using hypothetical inflow hydrographs in an artificial channel. As input parameters, first model needs the initial condition, upstream boundary condition, Manning's roughness coefficient, length of the routing reach, cross-sections of the river reach and the bed slope, while the latter one requires the initial condition, upstream boundary condition and the hydrologic parameters (three parameters which can be calibrated using flood hydrographs of the upstream and downstream sections). The VPMM model was examined by available Manning's roughness values, whereas the NLM model was tested in both calibration and validation steps. As final conclusion, Perumal et al. (2017) claimed that the NLM model should be retired from the literature of the Muskingum model. While the author's intention is laudable, this comment examines some important issues in the subject matter of the original study.
Gomes, Perpétua; Palma, Ana Carolina; Cabanas, Joaquim; Abecasis, Ana; Carvalho, Ana Patrícia; Ziermann, Rainer; Diogo, Isabel; Gonçalves, Fátima; Lobo, Céu Sousa; Camacho, Ricardo
2006-08-01
Quantitation of HIV-1 RNA levels in plasma has an undisputed prognostic value and is extremely important for evaluating response to antiretroviral therapy. The purpose of this study was to evaluate the performance of the real-time PCR COBAS TaqMan 48 analyser, comparing it to the existing VERSANT 3.0 (bDNA) for HIV-1 RNA quantitation in plasma of individuals infected with different HIV-1 subtypes (104 blood samples). A positive linear correlation between the two tests (r2 = 0.88) was found. Quantitation by the COBAS TaqMan assay was approximately 0.32log10 higher than by bDNA. The relationship between the two assays was similar within all subtypes with a Deming regression of <1 and <0 for the Bland-Altman plots. Overall, no significant differences were found in plasma viral load quantitation in different HIV-1 subtypes between both assays; therefore these assays are suitable for viral load quantitation of highly genetically diverse HIV-1 plasma samples.
Preparation of an oakmoss absolute with reduced allergenic potential.
Ehret, C; Maupetit, P; Petrzilka, M; Klecak, G
1992-06-01
Synopsis Oakmoss absolute, an extract of the lichen Evernia prunastri, is known to cause allergenic skin reactions due to the presence of certain aromatic aldehydes such as atranorin, chloratranorin, ethyl hematommate and ethyl chlorohematommate. In this paper it is shown that treatment of Oakmoss absolute with amino acids such as lysine and/or leucine, lowers considerably the content of these allergenic constituents including atranol and chloratranol. The resulting Oakmoss absolute, which exhibits an excellent olfactive quality, was tested extensively in comparative studies on guinea pigs and on man. The results of the Guinea Pig Maximization Test (GPMT) and Human Repeated Insult Patch Test (HRIPT) indicate that, in comparison with the commercial test sample, the allergenicity of this new quality of Oakmoss absolute was considerably reduced, and consequently better skin tolerance of this fragrance for man was achieved.
Emblem - Third (3rd) Manned Skylab (SL) Mission - SL-4
1972-11-14
S72-53094 (For release February 1973) --- This is the emblem for the third manned Skylab mission. It will be a mission of up to 56 days. Skylab is an experimental space station consisting of a 100-ton laboratory complex in which medical, scientific and technological experiments will be performed in Earth orbit. The members of the crew will be astronaut Gerald P. Carr, commander; scientist-astronaut Edward G. Gibson, science pilot; and astronaut William R. Pogue, pilot. The symbols in the patch refer to the three major areas of investigation proposed in the mission. The tree represents man's natural environment and relates directly to the Skylab mission objectives of advancing the study of Earth resources. The hydrogen atom, as the basic building block of the universe, represents man's exploration of the physical world, his application of knowledge, and his development of technology. Since the sun is composed primarily of hydrogen, it is appropriate that the symbol refers to the solar physics mission objectives. The human silhouette represents mankind and the human capacity to direct technology with a wisdom tempered by regard for his natural environment. It also directly relates to the Skylab medical studies of man himself. The rainbow, adopted from the Biblical story of the flood, symbolizes the promise that is offered man. It embraces man and extends to the tree and the hydrogen atom emphasizing man's pivotal role in the conciliation of technology with nature. Photo credit: NASA
Shanmugam, Vedapuri; Azarskova, Marianna; Nguyen, Shon; Hurlston, Mackenzie; Sabatier, Jennifer; Zhang, Guoqing; Osmanov, Saladin; Ellenberger, Dennis; Yang, Chunfu; Vitek, Charles; Liulchuk, Maria; Nizova, Natalya
2015-01-01
An accurate accessible test for early infant diagnosis (EID) is crucial for identifying HIV-infected infants and linking them to treatment. To improve EID services in Ukraine, dried blood spot (DBS) samples obtained from 237 HIV-exposed children (≤18 months of age) in six regions in Ukraine in 2012 to 2013 were tested with the AmpliSens DNA-HIV-FRT assay, the Roche COBAS AmpliPrep/COBAS TaqMan (CAP/CTM) HIV-1 Qual test, and the Abbott RealTime HIV-1 Qualitative assay. In comparison with the paired whole-blood results generated from AmpliSens testing at the oblast HIV reference laboratories in Ukraine, the sensitivity was 0.99 (95% confidence interval [CI], 0.95 to 1.00) for the AmpliSens and Roche CAP/CTM Qual assays and 0.96 (95% CI, 0.90 to 0.98) for the Abbott Qualitative assay. The specificity was 1.00 (95% CI, 0.97 to 1.00) for the AmpliSens and Abbott Qualitative assays and 0.99 (95% CI, 0.96 to 1.00) for the Roche CAP/CTM Qual assay. McNemar analysis indicated that the proportions of positive results for the tests were not significantly different (P > 0.05). Cohen's kappa (0.97 to 0.99) indicated almost perfect agreement among the three tests. These results indicated that the AmpliSens DBS and whole-blood tests performed equally well and were comparable to the two commercially available EID tests. More importantly, the performance characteristics of the AmpliSens DBS test meets the World Health Organization EID test requirements; implementing AmpliSens DBS testing might improve EID services in resource-limited settings. PMID:26447114
STV engine design considerations
NASA Technical Reports Server (NTRS)
1991-01-01
The topics covered include the following: (1) engine design criteria and issues; (2) design requirements for man rating; (3) test requirements for man rating; (4) design requirements for space basing; (5) engine operation requirements; (6) health monitoring; (7) lunar transfer vehicle (LTV) feed system; (8) lunar excursion vehicle (LEV) propellant system; (9) area ratio gimbal angle limits; (10) reaction control system; and (11) engine configuration and characteristics. This document is presented in viewgraph form.
Technology advancement of the electrochemical CO2 concentrating process
NASA Technical Reports Server (NTRS)
Schubert, F. H.; Woods, R. R.; Hallick, T. M.; Heppner, D. B.
1977-01-01
A five-cell, liquid-cooled advanced electrochemical depolarized carbon dioxide concentrator module was fabricated. The cells utilized the advanced, lightweight, plated anode current collector concept and internal liquid-cooling. The five cell module was designed to meet the carbon dioxide removal requirements of one man and was assembled using plexiglass endplates. This one-man module was tested as part of an integrated oxygen generation and recovery subsystem.
Manned maneuvering unit latching mechanism
NASA Technical Reports Server (NTRS)
Allton, C. S.
1980-01-01
The astronaut/Manned Maneuvering Unit interface, which presented a challenging set of requirements for a latching mechanism, is described. A spring loaded cam segment with variable ratio pulley release actuator was developed to meet the requirements. To preclude jamming of the mechanism, special precautions were taken such as spring loaded bearing points and careful selection of materials to resist cold welding. The mechanism successfully passed a number of tests which partially simulated orbital conditions.
1973-05-01
SA-206 lifts off from Kennedy Space Center's launch complex 39B, in Florida, on May 25, 1973, for the first manned Skylab mission (SL-2) with astronauts Pete Conrad, Joseph Kerwin, and Paul Weitz. The Saturn IB, developed under the direction of the Marshall Space Flight Center (MSFC), launched five manned Earth-orbital missions between 1968 and 1975: Apollo 7, Skylab 2, Skylab 3, Skylab 4, and the Apollo-Soyuz Test Project (ASTP).
1988-10-03
in Yunnan Province 38 Identification of Mycotoxins in Shaanxi Livestock Fodder 41 Aflotoxin Contamination of Peanut Products Surveyed 41 New Test...changes in man-to-man relations. It is said that the law of value is being used to effect the economic reform and to guide production, but frequently...Marx in his days. It has realized the defects in its very system and has by itself effected adjustments. Since the great economic crash and
NASA Technical Reports Server (NTRS)
Woods, R. R.; Heppner, D. B.; Marshall, R. D.; Quattrone, P. D.
1979-01-01
As the length of manned space missions increase, more ambitious extravehicular activities (EVAs) are required. For the projected longer mission the use of expendables in the portable life support system (PLSS) will become prohibited due to high launch weight and volume requirements. Therefore, the development of a regenerable CO2 absorber for the PLSS application is highly desirable. The paper discusses the concept, regeneration mechanism, performance, system design, and absorption/regeneration cycle testing of a most promising concept known as ERCA (Electrochemically Regenerable CO2 Absorber). This concept is based on absorbing CO2 into an alkaline absorbent similar to LiOH. The absorbent is an aqueous solution supported in a porous matrix which can be electrochemically regenerated on board the primary space vehicle. With the metabolic CO2 recovery the ERCA concept results in a totally regenerable CO2 scrubber. The ERCA test hardware has passed 200 absorption/regeneration cycles without performance degradation.
Design and Demonstration of a Miniature Lidar System for Rover Applications
NASA Technical Reports Server (NTRS)
Robinson, Benjamin
2011-01-01
Public awareness of harmful human environmental effects such as global warming has increased greatly in recent years and researchers have increased their efforts in gaining more knowledge about the Earth's atmosphere. Natural and man-made processes pose threats to the environment and human life, so knowledge of all atmospheric processes is necessary. Ozone and aerosols are important factors in many atmospheric processes and active remote sensing techniques provide a way to analyze their quantity and distribution. A compact ground-based lidar system for a robotic platform meant for atmospheric aerosol measurements was designed, tested, and evaluated. The system will eventually be deployed for ozone and aerosol measurements in Mars and lunar missions to improve our knowledge and understanding of atmospheres on Mars and the Moon. Atmospheric testing was performed to test the operability of the receiver system to acquire the lidar return signal from clouds and aerosols.
The effect of evaluation on co-occurrence memory judgement.
Bar-Anan, Yoav; Amzaleg-David, Efrat
2014-01-01
Three experiments tested the effect of an attitude towards an object on the memory judgement of whether this object co-occurred with positive versus negative stimuli. We induced positive or negative attitudes towards novel male stimuli, and paired each man with an equal number of positive and negative animals. In a memory test, participants reported more co-occurrences of same-valence man/animal pairs than opposite-valence pairs. This valence-compatibility effect occurred even when attitudes were induced after the pairing (Experiment 1), when participants knew that each man occurred with an equal number of positive and negative animals (Experiment 2), and in reports of clear memory of pairs that did not co-occur (Experiment 3). The present findings suggest that evaluation causes illusory correlation even when the co-occurring stimuli are not traits or behaviours attributed to the attitude object. The results question the validity of co-occurrence memory judgements as measures of co-occurrence awareness in evaluative conditioning (EC) research.
Man/Machine Interaction Dynamics And Performance (MMIDAP) capability
NASA Technical Reports Server (NTRS)
Frisch, Harold P.
1991-01-01
The creation of an ability to study interaction dynamics between a machine and its human operator can be approached from a myriad of directions. The Man/Machine Interaction Dynamics and Performance (MMIDAP) project seeks to create an ability to study the consequences of machine design alternatives relative to the performance of both machine and operator. The class of machines to which this study is directed includes those that require the intelligent physical exertions of a human operator. While Goddard's Flight Telerobotic's program was expected to be a major user, basic engineering design and biomedical applications reach far beyond telerobotics. Ongoing efforts are outlined of the GSFC and its University and small business collaborators to integrate both human performance and musculoskeletal data bases with analysis capabilities necessary to enable the study of dynamic actions, reactions, and performance of coupled machine/operator systems.
Microgravity Active Vibration Isolation System on Parabolic Flights
NASA Astrophysics Data System (ADS)
Dong, Wenbo; Pletser, Vladimir; Yang, Yang
2016-07-01
The Microgravity Active Vibration Isolation System (MAIS) aims at reducing on-orbit vibrations, providing a better controlled lower gravity environment for microgravity physical science experiments. The MAIS will be launched on Tianzhou-1, the first cargo ship of the China Manned Space Program. The principle of the MAIS is to suspend with electro-magnetic actuators a scientific payload, isolating it from the vibrating stator. The MAIS's vibration isolation capability is frequency-dependent and a decrease of vibration of about 40dB can be attained. The MAIS can accommodate 20kg of scientific payload or sample unit, and provide 30W of power and 1Mbps of data transmission. The MAIS is developed to support microgravity scientific experiments on manned platforms in low earth orbit, in order to meet the scientific requirements for fluid physics, materials science, and fundamental physics investigations, which usually need a very quiet environment, increasing their chances of success and their scientific outcomes. The results of scientific experiments and technology tests obtained with the MAIS will be used to improve future space based research. As the suspension force acting on the payload is very small, the MAIS can only be operative and tested in a weightless environment. The 'Deutsches Zentrum für Luft- und Raumfahrt e.V.' (DLR, German Aerospace Centre) granted a flight opportunity to the MAIS experiment to be tested during its 27th parabolic flight campaign of September 2015 performed on the A310 ZERO-G aircraft managed by the French company Novespace, a subsidiary of the 'Centre National d'Etudes Spatiales' (CNES, French Space Agency). The experiment results confirmed that the 6 degrees of freedom motion control technique was effective, and that the vibration isolation performance fulfilled perfectly the expectations based on theoretical analyses and simulations. This paper will present the design of the MAIS and the experiment results obtained during the parabolic flight campaign.