Sample records for manual control methods

  1. A comparison of treatment effectiveness between the CAD/CAM method and the manual method for managing adolescent idiopathic scoliosis.

    PubMed

    Wong, M S; Cheng, J C Y; Lo, K H

    2005-04-01

    The treatment effectiveness of the CAD/CAM method and the manual method in managing adolescent idiopathic scoliosis (AIS) was compared. Forty subjects were recruited with twenty subjects for each method. The clinical parameters namely Cobb's angle and apical vertebral rotation were evaluated at the pre-brace and the immediate in-brace visits. The results demonstrated that orthotic treatments rendered by the CAD/CAM method and the conventional manual method were effective in providing initial control of Cobb's angle. Significant decreases (p < 0.05) were found between the pre-brace and immediate in-brace visits for both methods. The mean reductions of Cobb's angle were 12.8 degrees (41.9%) for the CAD/CAM method and 9.8 degrees (32.1%) for the manual method. An initial control of the apical vertebral rotation was not shown in this study. In the comparison between the CAD/CAM method and the manual method, no significant difference was found in the control of Cobb's angle and apical vertebral rotation. The current study demonstrated that the CAD/CAM method can provide similar result in the initial stage of treatment as compared with the manual method.

  2. Prototype of a computer method for designing and analyzing heating, ventilating and air conditioning proportional, electronic control systems

    NASA Astrophysics Data System (ADS)

    Barlow, Steven J.

    1986-09-01

    The Air Force needs a better method of designing new and retrofit heating, ventilating and air conditioning (HVAC) control systems. Air Force engineers currently use manual design/predict/verify procedures taught at the Air Force Institute of Technology, School of Civil Engineering, HVAC Control Systems course. These existing manual procedures are iterative and time-consuming. The objectives of this research were to: (1) Locate and, if necessary, modify an existing computer-based method for designing and analyzing HVAC control systems that is compatible with the HVAC Control Systems manual procedures, or (2) Develop a new computer-based method of designing and analyzing HVAC control systems that is compatible with the existing manual procedures. Five existing computer packages were investigated in accordance with the first objective: MODSIM (for modular simulation), HVACSIM (for HVAC simulation), TRNSYS (for transient system simulation), BLAST (for building load and system thermodynamics) and Elite Building Energy Analysis Program. None were found to be compatible or adaptable to the existing manual procedures, and consequently, a prototype of a new computer method was developed in accordance with the second research objective.

  3. Review of manual control methods for handheld maneuverable instruments.

    PubMed

    Fan, Chunman; Dodou, Dimitra; Breedveld, Paul

    2013-06-01

    By the introduction of new technologies, surgical procedures have been varying from free access in open surgery towards limited access in minimal access surgery. Improving access to difficult-to-reach anatomic sites, e.g. in neurosurgery or percutaneous interventions, needs advanced maneuverable instrumentation. Advances in maneuverable technology require the development of dedicated methods enabling surgeons to stay in direct, manual control of these complex instruments. This article gives an overview of the state-of-the-art in the development of manual control methods for handheld maneuverable instruments. It categorizes the manual control methods in three levels: a) number of steerable segments, b) number of Degrees Of Freedom (DOF), and c) coupling between control motion of the handle and steering motion of the tip. The literature research was completed by using Web of Science, Scopus and PubMed. The study shows that in controlling single steerable segments, direct as well as indirect control methods have been developed, whereas in controlling multiple steerable segments, a gradual shift can be noticed from parallel and serial control to integrated control. The development of multi-segmented maneuverable instruments is still at an early stage, and an intuitive and effective method to control them has to become a primary focus in the domain of minimal access surgery.

  4. Applicator Training Manual for: Public Health Pest Control.

    ERIC Educational Resources Information Center

    Moore, E. E.

    This manual gives the life cycle and habitats, public health importance, methods of non-chemical control, and pesticides and methods of application for mosquitoes, flies, bedbugs, fleas, lice, cockroaches, venomous anthropods, ticks and chiggers, and rodents. (BB)

  5. Manual, mechanical, and cultural control methds and tools

    Treesearch

    Steven Manning; James Miller

    2011-01-01

    There are many land management scenarios where chemicals are not the ideal choice for controlling invasive plants. More often than not, the best approach is the use of integrated pest management involving a variety of control methods. Maximizing the value of mechanical, manual, and cultural control methods with the added benefit of selective herbicides can offer the...

  6. Manual on Bibliographic Control.

    ERIC Educational Resources Information Center

    International Federation of Library Associations, The Hague (Netherlands).

    This manual outlines objectives, functions, and methods for establishing national bibliographic control as part of the development of a worldwide system for the control and exchange of bibliographic information. Chapters cover: (1) definitions of bibliographic control and related concepts including Universal Bibliographic Control (UBC) and…

  7. Comparison of manual & automated analysis methods for corneal endothelial cell density measurements by specular microscopy.

    PubMed

    Huang, Jianyan; Maram, Jyotsna; Tepelus, Tudor C; Modak, Cristina; Marion, Ken; Sadda, SriniVas R; Chopra, Vikas; Lee, Olivia L

    2017-08-07

    To determine the reliability of corneal endothelial cell density (ECD) obtained by automated specular microscopy versus that of validated manual methods and factors that predict such reliability. Sharp central images from 94 control and 106 glaucomatous eyes were captured with Konan specular microscope NSP-9900. All images were analyzed by trained graders using Konan CellChek Software, employing the fully- and semi-automated methods as well as Center Method. Images with low cell count (input cells number <100) and/or guttata were compared with the Center and Flex-Center Methods. ECDs were compared and absolute error was used to assess variation. The effect on ECD of age, cell count, cell size, and cell size variation was evaluated. No significant difference was observed between the Center and Flex-Center Methods in corneas with guttata (p=0.48) or low ECD (p=0.11). No difference (p=0.32) was observed in ECD of normal controls <40 yrs old between the fully-automated method and manual Center Method. However, in older controls and glaucomatous eyes, ECD was overestimated by the fully-automated method (p=0.034) and semi-automated method (p=0.025) as compared to manual method. Our findings show that automated analysis significantly overestimates ECD in the eyes with high polymegathism and/or large cell size, compared to the manual method. Therefore, we discourage reliance upon the fully-automated method alone to perform specular microscopy analysis, particularly if an accurate ECD value is imperative. Copyright © 2017. Published by Elsevier España, S.L.U.

  8. Microbial ecology laboratory procedures manual NASA/MSFC

    NASA Technical Reports Server (NTRS)

    Huff, Timothy L.

    1990-01-01

    An essential part of the efficient operation of any microbiology laboratory involved in sample analysis is a standard procedures manual. The purpose of this manual is to provide concise and well defined instructions on routine technical procedures involving sample analysis and methods for monitoring and maintaining quality control within the laboratory. Of equal importance is the safe operation of the laboratory. This manual outlines detailed procedures to be followed in the microbial ecology laboratory to assure safety, analytical control, and validity of results.

  9. Annual Conference on Manual Control (20th) Held in California on June 12 - 14, 1984. Volume 1

    DTIC Science & Technology

    1984-06-14

    and in conjunction with movements of other joints. Much of this data is for atheletic performance . Components of such data can be simulated using JAMM... PERFORMANCE Chairman: Mr. Henry Jex Jewell, W. & Clement, W.F. A method for measuring the effective throughput time delay in simulated displays involving...manual control. 173 Allen, R. W. & DiMarco, R. J. Effects of transport delays on manual control system performance . 185 Sanders, K. E., Anderson, D. C

  10. Tree and brush control for county road right-of-way.

    DOT National Transportation Integrated Search

    2002-10-01

    This manual summarizes the roadside tree and brush control methods used by all of Iowa's 99 : counties. It is based on interviews conducted in Spring 2002 with county engineers, roadside : managers and others. The target audience of this manual is th...

  11. Applicator Training Manual for: Agricultural Animal Pest Control.

    ERIC Educational Resources Information Center

    Christensen, Christian M.

    This manual discusses pesticide safety and environmental considerations, pesticide toxicity, residue potential, pesticide formulations, and application techniques. In addition, descriptions of, and methods for controlling insects and related pests that attack cattle, sheep and goats, swine, horses and other equines, and poultry are given. These…

  12. Right Of Way Pest Control. Manual 88.

    ERIC Educational Resources Information Center

    Missouri Univ., Columbia. Agricultural Experiment Station.

    This training manual provides information needed to meet the minimum EPA standards for certification as a commercial applicator of pesticides in the right-of-way pest control category. The text discusses types of vegetation, the nature of herbicides, application methods, use for specific situations, and safety precautions. (CS)

  13. Interactive 3D segmentation using connected orthogonal contours.

    PubMed

    de Bruin, P W; Dercksen, V J; Post, F H; Vossepoel, A M; Streekstra, G J; Vos, F M

    2005-05-01

    This paper describes a new method for interactive segmentation that is based on cross-sectional design and 3D modelling. The method represents a 3D model by a set of connected contours that are planar and orthogonal. Planar contours overlayed on image data are easily manipulated and linked contours reduce the amount of user interaction.1 This method solves the contour-to-contour correspondence problem and can capture extrema of objects in a more flexible way than manual segmentation of a stack of 2D images. The resulting 3D model is guaranteed to be free of geometric and topological errors. We show that manual segmentation using connected orthogonal contours has great advantages over conventional manual segmentation. Furthermore, the method provides effective feedback and control for creating an initial model for, and control and steering of, (semi-)automatic segmentation methods.

  14. WHO Working Group on revision of the Manual of Laboratory Methods for Testing DTP Vaccines-Report of two meetings held on 20-21 July 2006 and 28-30 March 2007, Geneva, Switzerland.

    PubMed

    Corbel, Michael J; Das, Rose Gaines; Lei, Dianliang; Xing, Dorothy K L; Horiuchi, Yoshinobu; Dobbelaer, Roland

    2008-04-07

    This report reflects the discussion and conclusions of a WHO group of experts from National Regulatory Authorities (NRAs), National Control Laboratories (NCLs), vaccine industries and other relevant institutions involved in standardization and control of diphtheria, tetanus and pertussis vaccines (DTP), held on 20-21 July 2006 and 28-30 March 2007, in Geneva Switzerland for the revision of WHO Manual for quality control of DTP vaccines. Taking into account recent developments and standardization in quality control methods and the revision of WHO recommendations for D, T, P vaccines, and a need for updating the manual has been recognized. In these two meetings the current situation of quality control methods in terms of potency, safety and identity tests for DTP vaccines and statistical analysis of data were reviewed. Based on the WHO recommendations and recent validation of testing methods, the content of current manual were reviewed and discussed. The group agreed that the principles to be observed in selecting methods included identifying those critical for assuring safety, efficacy and quality and which were consistent with WHO recommendations/requirements. Methods that were well recognized but not yet included in current Recommendations should be taken into account. These would include in vivo and/or in vitro methods for determining potency, safety testing and identity. The statistical analysis of the data should be revised and updated. It was noted that the mouse based assays for toxoid potency were still quite widely used and it was desirable to establish appropriate standards for these to enable the results to be related to the standard guinea pig assays. The working group was met again to review the first drafts and to input further suggestions or amendments to the contributions of the drafting groups. The revised manual was to be finalized and published by WHO.

  15. Fiscal Accounting Manual.

    ERIC Educational Resources Information Center

    California State Dept. of Housing and Community Development, Sacramento. Indian Assistance Program.

    Written in simple, easy to understand form, the manual provides a vehicle for the untrained person in bookkeeping to control funds received from grants for Indian Tribal Councils and Indian organizations. The method used to control grants (federal, state, or private) is fund accounting, designed to organize rendering services on a non-profit…

  16. The paradox of sham therapy and placebo effect in osteopathy

    PubMed Central

    Cerritelli, Francesco; Verzella, Marco; Cicchitti, Luca; D’Alessandro, Giandomenico; Vanacore, Nicola

    2016-01-01

    Abstract Background: Placebo, defined as “false treatment,” is a common gold-standard method to assess the validity of a therapy both in pharmacological trials and manual medicine research where placebo is also referred to as “sham therapy.” In the medical literature, guidelines have been proposed on how to conduct robust placebo-controlled trials, but mainly in a drug-based scenario. In contrast, there are not precise guidelines on how to conduct a placebo-controlled in manual medicine trials (particularly osteopathy). The aim of the present systematic review was to report how and what type of sham methods, dosage, operator characteristics, and patient types were used in osteopathic clinical trials and, eventually, assess sham clinical effectiveness. Methods: A systematic Cochrane-based review was conducted by analyzing the osteopathic trials that used both manual and nonmanual placebo control. Searches were conducted on 8 databases from journal inception to December 2015 using a pragmatic literature search approach. Two independent reviewers conducted the study selection and data extraction for each study. The risk of bias was evaluated according to the Cochrane methods. Results: A total of 64 studies were eligible for analysis collecting a total of 5024 participants. More than half (43 studies) used a manual placebo; 9 studies used a nonmanual placebo; and 12 studies used both manual and nonmanual placebo. Data showed lack of reporting sham therapy information across studies. Risk of bias analysis demonstrated a high risk of bias for allocation, blinding of personnel and participants, selective, and other bias. To explore the clinical effects of sham therapies used, a quantitative analysis was planned. However, due to the high heterogeneity of sham approaches used no further analyses were performed. Conclusion: High heterogeneity regarding placebo used between studies, lack of reporting information on placebo methods and within-study variability between sham and real treatment procedures suggest prudence in reading and interpreting study findings in manual osteopathic randomized controlled trials (RCTs). Efforts must be made to promote guidelines to design the most reliable placebo for manual RCTs as a means of increasing the internal validity and improve external validity of findings. PMID:27583913

  17. Foot Pedals for Spacecraft Manual Control

    NASA Technical Reports Server (NTRS)

    Love, Stanley G.; Morin, Lee M.; McCabe, Mary

    2010-01-01

    Fifty years ago, NASA decided that the cockpit controls in spacecraft should be like the ones in airplanes. But controls based on the stick and rudder may not be best way to manually control a vehicle in space. A different method is based on submersible vehicles controlled with foot pedals. A new pilot can learn the sub's control scheme in minutes and drive it hands-free. We are building a pair of foot pedals for spacecraft control, and will test them in a spacecraft flight simulator.

  18. The paradox of sham therapy and placebo effect in osteopathy: A systematic review.

    PubMed

    Cerritelli, Francesco; Verzella, Marco; Cicchitti, Luca; D'Alessandro, Giandomenico; Vanacore, Nicola

    2016-08-01

    Placebo, defined as "false treatment," is a common gold-standard method to assess the validity of a therapy both in pharmacological trials and manual medicine research where placebo is also referred to as "sham therapy." In the medical literature, guidelines have been proposed on how to conduct robust placebo-controlled trials, but mainly in a drug-based scenario. In contrast, there are not precise guidelines on how to conduct a placebo-controlled in manual medicine trials (particularly osteopathy). The aim of the present systematic review was to report how and what type of sham methods, dosage, operator characteristics, and patient types were used in osteopathic clinical trials and, eventually, assess sham clinical effectiveness. A systematic Cochrane-based review was conducted by analyzing the osteopathic trials that used both manual and nonmanual placebo control. Searches were conducted on 8 databases from journal inception to December 2015 using a pragmatic literature search approach. Two independent reviewers conducted the study selection and data extraction for each study. The risk of bias was evaluated according to the Cochrane methods. A total of 64 studies were eligible for analysis collecting a total of 5024 participants. More than half (43 studies) used a manual placebo; 9 studies used a nonmanual placebo; and 12 studies used both manual and nonmanual placebo. Data showed lack of reporting sham therapy information across studies. Risk of bias analysis demonstrated a high risk of bias for allocation, blinding of personnel and participants, selective, and other bias. To explore the clinical effects of sham therapies used, a quantitative analysis was planned. However, due to the high heterogeneity of sham approaches used no further analyses were performed. High heterogeneity regarding placebo used between studies, lack of reporting information on placebo methods and within-study variability between sham and real treatment procedures suggest prudence in reading and interpreting study findings in manual osteopathic randomized controlled trials (RCTs). Efforts must be made to promote guidelines to design the most reliable placebo for manual RCTs as a means of increasing the internal validity and improve external validity of findings.

  19. Manual herbicide application methods for managing vegetation in Appalachian hardwood forests

    Treesearch

    Jeffrey D. Kochenderfer; James N. Kochenderfer; Gary W. Miller

    2012-01-01

    Four manual herbicide application methods are described for use in Appalachian hardwood forests. Stem injection, basal spray, cut-stump, and foliar spray techniques can be used to control interfering vegetation and promote the development of desirable reproduction and valuable crop trees in hardwood forests. Guidelines are presented to help the user select the...

  20. A Guide to the Organization of Library Collections, For the Use of Students of Library Science.

    ERIC Educational Resources Information Center

    Wetmore, Rosamond B.

    This manual serves as a guide to the organization of library collections for Ball State University students in the graduate school of library science. The manual presents, in a concise manner, methods and card forms used in establishing bibliographic controls over a library collection. It is intended that the manual will be used in conjunction…

  1. The effectiveness and cost-evaluation of manual therapy and physical therapy in patients with sub-acute and chronic non specific neck pain. Rationale and design of a Randomized Controlled Trial (RCT)

    PubMed Central

    2010-01-01

    Background Manual Therapy applied to patients with non specific neck pain has been investigated several times. In the Netherlands, manual therapy as applied according to the Utrecht School of Manual Therapy (MTU) has not been the subject of a randomized controlled trial. MTU differs in diagnoses and treatment from other forms of manual therapy. Methods/Design This is a single blind randomized controlled trial in patients with sub-acute and chronic non specific neck pain. Patients with neck complaints existing for two weeks (minimum) till one year (maximum) will participate in the trial. 180 participants will be recruited in thirteen primary health care centres in the Netherlands. The experimental group will be treated with MTU during a six week period. The control group will be treated with physical therapy (standard care, mainly active exercise therapy), also for a period of six weeks. Primary outcomes are Global Perceived Effect (GPE) and functional status (Neck Disability Index (NDI-DV)). Secondary outcomes are neck pain (Numeric Rating Scale (NRS)), Eurocol, costs and quality of life (SF36). Discussion This paper presents details on the rationale of MTU, design, methods and operational aspects of the trial. Trial registration ClinicalTrials.gov Identifier: NCT00713843 PMID:20096136

  2. Applicator Training Manual for: Forest Pest Control.

    ERIC Educational Resources Information Center

    Newman, Jim

    Described in this manual is the use of insecticides, fungicides, and herbicides in forestry. Both diseases and insects found in hardwoods and conifers are covered. Detailed information is given on methods of herbicide application. Finally, five important environmental considerations are given. (BB)

  3. Graph theoretical stable allocation as a tool for reproduction of control by human operators

    NASA Astrophysics Data System (ADS)

    van Nooijen, Ronald; Ertsen, Maurits; Kolechkina, Alla

    2016-04-01

    During the design of central control algorithms for existing water resource systems under manual control it is important to consider the interaction with parts of the system that remain under manual control and to compare the proposed new system with the existing manual methods. In graph theory the "stable allocation" problem has good solution algorithms and allows for formulation of flow distribution problems in terms of priorities. As a test case for the use of this approach we used the algorithm to derive water allocation rules for the Gezira Scheme, an irrigation system located between the Blue and White Niles south of Khartoum. In 1925, Gezira started with 300,000 acres; currently it covers close to two million acres.

  4. The Identification and Modeling of Visual Cue Usage in Manual Control Task Experiments

    NASA Technical Reports Server (NTRS)

    Sweet, Barbara Townsend; Trejo, Leonard J. (Technical Monitor)

    1999-01-01

    Many fields of endeavor require humans to conduct manual control tasks while viewing a perspective scene. Manual control refers to tasks in which continuous, or nearly continuous, control adjustments are required. Examples include flying an aircraft, driving a car, and riding a bicycle. Perspective scenes can arise through natural viewing of the world, simulation of a scene (as in flight simulators), or through imaging devices (such as the cameras on an unmanned aerospace vehicle). Designers frequently have some degree of control over the content and characteristics of a perspective scene; airport designers can choose runway markings, vehicle designers can influence the size and shape of windows, as well as the location of the pilot, and simulator database designers can choose scene complexity and content. Little theoretical framework exists to help designers determine the answers to questions related to perspective scene content. An empirical approach is most commonly used to determine optimum perspective scene configurations. The goal of the research effort described in this dissertation has been to provide a tool for modeling the characteristics of human operators conducting manual control tasks with perspective-scene viewing. This is done for the purpose of providing an algorithmic, as opposed to empirical, method for analyzing the effects of changing perspective scene content for closed-loop manual control tasks.

  5. Iowa Commercial Pesticide Applicator Manual, Category 1D: Fruit and Vegetable Pest Control and Supplement. CS-12 and CS-12a.

    ERIC Educational Resources Information Center

    Epstein, Abraham H.; And Others

    This manual provides information needed to meet specific standards for certification as a pesticide applicator. The major weed and insect pests of fruits and vegetables are pictured and discussed. Suggested methods for control by utilizing herbicides and pesticides are presented with attention given to safety considerations for both humans and the…

  6. A Manual of Mosquito Control Projects and Committee Assignments for 4-H and Scouts Biology Class Projects, Organized Community Service Programs, and Individuals Interested in Environmental Management.

    ERIC Educational Resources Information Center

    Hart, Richard A.

    The mosquito control projects presented in this manual were prepared from an educational viewpoint and are intended for use by students in 4-H and Scouts and as a supplement to high school and college biology course work. The major emphasis of the projects is on integrated pest management, an approach utilizing cost-effective control methods which…

  7. New techniques for the analysis of manual control systems. [mathematical models of human operator behavior

    NASA Technical Reports Server (NTRS)

    Bekey, G. A.

    1971-01-01

    Studies are summarized on the application of advanced analytical and computational methods to the development of mathematical models of human controllers in multiaxis manual control systems. Specific accomplishments include the following: (1) The development of analytical and computer methods for the measurement of random parameters in linear models of human operators. (2) Discrete models of human operator behavior in a multiple display situation were developed. (3) Sensitivity techniques were developed which make possible the identification of unknown sampling intervals in linear systems. (4) The adaptive behavior of human operators following particular classes of vehicle failures was studied and a model structure proposed.

  8. Automatic and manual segmentation of healthy retinas using high-definition optical coherence tomography.

    PubMed

    Golbaz, Isabelle; Ahlers, Christian; Goesseringer, Nina; Stock, Geraldine; Geitzenauer, Wolfgang; Prünte, Christian; Schmidt-Erfurth, Ursula Margarethe

    2011-03-01

    This study compared automatic- and manual segmentation modalities in the retina of healthy eyes using high-definition optical coherence tomography (HD-OCT). Twenty retinas in 20 healthy individuals were examined using an HD-OCT system (Carl Zeiss Meditec, Inc.). Three-dimensional imaging was performed with an axial resolution of 6 μm at a maximum scanning speed of 25,000 A-scans/second. Volumes of 6 × 6 × 2 mm were scanned. Scans were analysed using a matlab-based algorithm and a manual segmentation software system (3D-Doctor). The volume values calculated by the two methods were compared. Statistical analysis revealed a high correlation between automatic and manual modes of segmentation. The automatic mode of measuring retinal volume and the corresponding three-dimensional images provided similar results to the manual segmentation procedure. Both methods were able to visualize retinal and subretinal features accurately. This study compared two methods of assessing retinal volume using HD-OCT scans in healthy retinas. Both methods were able to provide realistic volumetric data when applied to raster scan sets. Manual segmentation methods represent an adequate tool with which to control automated processes and to identify clinically relevant structures, whereas automatic procedures will be needed to obtain data in larger patient populations. © 2009 The Authors. Journal compilation © 2009 Acta Ophthalmol.

  9. Electrostatic discharge control for STDN stations

    NASA Technical Reports Server (NTRS)

    Mckiernan, J.

    1983-01-01

    This manual defines the requirements and control methods necessary to control the effect of electrostatic discharges that damage or destroy electronic equipment components. Test procedures for measuring the effectiveness of the control are included.

  10. Proceedings of the 8th Annual Conference on Manual Control

    NASA Technical Reports Server (NTRS)

    Pew, R. W.

    1972-01-01

    The volume presents recent developments in the field of manual control theory and applications. The papers give analytical methods as well as examples of the important interplay between man and machine, such as how man controls and stabilizes machine dynamics, and how machines extend man's capability. Included in the broad range of subjects are procedures to evaluate and identify display systems, controllers, manipulators, human operators, aircraft, and non-flying vehicles. Of particular interest is the continuing trend of applying control theory to problems in medicine and psychology, as well as to problems in vehicle control.

  11. Aircraft noise prediction program user's manual

    NASA Technical Reports Server (NTRS)

    Gillian, R. E.

    1982-01-01

    The Aircraft Noise Prediction Program (ANOPP) predicts aircraft noise with the best methods available. This manual is designed to give the user an understanding of the capabilities of ANOPP and to show how to formulate problems and obtain solutions by using these capabilities. Sections within the manual document basic ANOPP concepts, ANOPP usage, ANOPP functional modules, ANOPP control statement procedure library, and ANOPP permanent data base. appendixes to the manual include information on preparing job decks for the operating systems in use, error diagnostics and recovery techniques, and a glossary of ANOPP terms.

  12. Interpretation of ANA Indirect Immunofluorescence Test Outside the Darkroom Using NOVA View Compared to Manual Microscopy

    PubMed Central

    Copple, Susan S.; Jaskowski, Troy D.; Giles, Rashelle; Hill, Harry R.

    2014-01-01

    Objective. To evaluate NOVA View with focus on reading archived images versus microscope based manual interpretation of ANA HEp-2 slides by an experienced, certified medical technologist. Methods. 369 well defined sera from: 44 rheumatoid arthritis, 50 systemic lupus erythematosus, 35 scleroderma, 19 Sjögren's syndrome, and 10 polymyositis patients as well as 99 healthy controls were examined. In addition, 12 defined sera from the Centers for Disease Control and 100 random patient sera sent to ARUP Laboratories for ANA HEp-2 IIF testing were included. Samples were read using the archived images on NOVA View and compared to results obtained from manual reading. Results. At a 1 : 40/1 : 80 dilution the resulting comparison demonstrated 94.8%/92.9% positive, 97.4%/97.4% negative, and 96.5%/96.2% total agreements between manual IIF and NOVA View archived images. Agreement of identifiable patterns between methods was 97%, with PCNA and mixed patterns undetermined. Conclusion. Excellent agreements were obtained between reading archived images on NOVA View and manually on a fluorescent microscope. In addition, workflow benefits were observed which need to be analyzed in future studies. PMID:24741573

  13. Iowa Commercial Pesticide Applicator Manual, Category 1C: Agricultural Crop Disease Control. CS-11.

    ERIC Educational Resources Information Center

    Nyvall, Robert F.; Ryan, Stephen O.

    This manual provides information needed to meet specific standards for certification as a pesticide applicator. It summarizes the economically important diseases of field and forage crops such as corn, soybeans and alfalfa. Special attention is given to pesticide application methods and safety. (CS)

  14. Comparison of automated erythrocytapheresis versus manual exchange transfusion to treat cerebral macrovasculopathy in sickle cell anemia.

    PubMed

    Koehl, Bérengère; Sommet, Julie; Holvoet, Laurent; Abdoul, Hendy; Boizeau, Priscilla; Ithier, Ghislaine; Missud, Florence; Couque, Nathalie; Verlhac, Suzanne; Voultoury, Pauline; Sellami, Fatiha; Baruchel, André; Benkerrou, Malika

    2016-05-01

    Chronic exchange transfusion is effective for primary and secondary prevention of stroke in children with sickle cell anemia (SCA). Erythrocytapheresis is recognized to be the most efficient approach; however, it is not widely implemented and is not suitable for all patients. The aim of our study was to compare automated exchange transfusion (AET) with our manual method of exchange transfusion and, in particular, to evaluate the efficacy, safety, and cost of our manual method. Thirty-nine SCA children with stroke and/or abnormal findings on transcranial Doppler were included in the study. We retrospectively analyzed 1353 exchange sessions, including 333 sessions of AET and 1020 sessions of manual exchange transfusion (MET). Both methods were well tolerated. The median decrease in hemoglobin (Hb)S per session was 21.5% with AET and 18.8% with our manual method (p < 0.0001) with no major increase in red blood cell consumption. Iron overload was well controlled, even with the manual method, with a median (interquartile range) ferritin level of 312 (152-994) µg/L after 24 months of transfusions. The main differences in annual cost relate to equipment costs, which were 74 times higher with the automated method. Our study shows that continuous MET has comparable efficacy to the automated method in terms of stroke prevention, decrease in HbS, and iron overload prevention. It is feasible in all hospital settings and is often combined with AET successively over time. © 2016 AABB.

  15. Effects of Selected Task Performance Criteria at Initiating Adaptive Task Real locations

    NASA Technical Reports Server (NTRS)

    Montgomery, Demaris A.

    2001-01-01

    In the current report various performance assessment methods used to initiate mode transfers between manual control and automation for adaptive task reallocation were tested. Participants monitored two secondary tasks for critical events while actively controlling a process in a fictional system. One of the secondary monitoring tasks could be automated whenever operators' performance was below acceptable levels. Automation of the secondary task and transfer of the secondary task back to manual control were either human- or machine-initiated. Human-initiated transfers were based on the operator's assessment of the current task demands while machine-initiated transfers were based on the operators' performance. Different performance assessment methods were tested in two separate experiments.

  16. Validation of a fibula graft cutting guide for mandibular reconstruction: experiment with rapid prototyping mandible model.

    PubMed

    Lim, Se-Ho; Kim, Yeon-Ho; Kim, Moon-Key; Nam, Woong; Kang, Sang-Hoon

    2016-12-01

    We examined whether cutting a fibula graft with a surgical guide template, prepared with computer-aided design/computer-aided manufacturing (CAD/CAM), would improve the precision and accuracy of mandibular reconstruction. Thirty mandibular rapid prototype (RP) models were allocated to experimental (N = 15) and control (N = 15) groups. Thirty identical fibular RP models were assigned randomly, 15 to each group. For reference, we prepared a reconstructed mandibular RP model with a three-dimensional printer, based on surgical simulation. In the experimental group, a stereolithography (STL) surgical guide template, based on simulation, was used for cutting the fibula graft. In the control group, the fibula graft was cut manually, with reference to the reconstructed RP mandible model. The mandibular reconstructions were compared to the surgical simulation, and errors were calculated for both the STL surgical guide and the manual methods. The average differences in three-dimensional, minimum distances between the reconstruction and simulation were 9.87 ± 6.32 mm (mean ± SD) for the STL surgical guide method and 14.76 ± 10.34 mm (mean ± SD) for the manual method. The STL surgical guide method incurred less error than the manual method in mandibular reconstruction. A fibula cutting guide improved the precision of reconstructing the mandible with a fibula graft.

  17. ISE: An Integrated Search Environment. The manual

    NASA Technical Reports Server (NTRS)

    Chu, Lon-Chan

    1992-01-01

    Integrated Search Environment (ISE), a software package that implements hierarchical searches with meta-control, is described in this manual. ISE is a collection of problem-independent routines to support solving searches. Mainly, these routines are core routines for solving a search problem and they handle the control of searches and maintain the statistics related to searches. By separating the problem-dependent and problem-independent components in ISE, new search methods based on a combination of existing methods can be developed by coding a single master control program. Further, new applications solved by searches can be developed by coding the problem-dependent parts and reusing the problem-independent parts already developed. Potential users of ISE are designers of new application solvers and new search algorithms, and users of experimental application solvers and search algorithms. The ISE is designed to be user-friendly and information rich. In this manual, the organization of ISE is described and several experiments carried out on ISE are also described.

  18. Automated Dissolution for Enteric-Coated Aspirin Tablets: A Case Study for Method Transfer to a RoboDis II.

    PubMed

    Ibrahim, Sarah A; Martini, Luigi

    2014-08-01

    Dissolution method transfer is a complicated yet common process in the pharmaceutical industry. With increased pharmaceutical product manufacturing and dissolution acceptance requirements, dissolution testing has become one of the most labor-intensive quality control testing methods. There is an increased trend for automation in dissolution testing, particularly for large pharmaceutical companies to reduce variability and increase personnel efficiency. There is no official guideline for dissolution testing method transfer from a manual, semi-automated, to automated dissolution tester. In this study, a manual multipoint dissolution testing procedure for an enteric-coated aspirin tablet was transferred effectively and reproducibly to a fully automated dissolution testing device, RoboDis II. Enteric-coated aspirin samples were used as a model formulation to assess the feasibility and accuracy of media pH change during continuous automated dissolution testing. Several RoboDis II parameters were evaluated to ensure the integrity and equivalency of dissolution method transfer from a manual dissolution tester. This current study provides a systematic outline for the transfer of the manual dissolution testing protocol to an automated dissolution tester. This study further supports that automated dissolution testers compliant with regulatory requirements and similar to manual dissolution testers facilitate method transfer. © 2014 Society for Laboratory Automation and Screening.

  19. An Experimental Comparison of Two Methods Of Teaching Numerical Control Manual Programming Concepts; Visual Media Versus Hands-On Equipment.

    ERIC Educational Resources Information Center

    Biekert, Russell

    Accompanying the rapid changes in technology has been a greater dependence on automation and numerical control, which has resulted in the need to find ways of preparing programers for industrial machines using numerical control. To compare the hands-on equipment method and a visual media method of teaching numerical control, an experimental and a…

  20. Comparison of tongue interface with keyboard for control of an assistive robotic arm.

    PubMed

    Struijk, Lotte N S Andreasen; Lontis, Romulus

    2017-07-01

    This paper demonstrates how an assistive 6 DoF robotic arm with a gripper can be controlled manually using a tongue interface. The proposed method suggests that it possible for a user to manipulate the surroundings with his or her tongue using the inductive tongue control system as deployed in this study. The sensors of an inductive tongue-computer interface were mapped to the Cartesian control of an assistive robotic arm. The resulting control system was tested manually in order to compare manual control of the robot using a standard keyboard and using the tongue interface. Two healthy subjects controlled the robotic arm to precisely move a bottle of water from one location to another. The results shows that the tongue interface was able to fully control the robotic arm in a similar manner as the standard keyboard resulting in the same number of successful manipulations and an average increase in task duration of up to 30% as compared with the standard keyboard.

  1. Efficacy of single-layer continuous suture of the posterior wall in anastomosis involving a difficult location of the digestive tract

    PubMed Central

    LI, GUO-CAI; XU, YONG; ZHANG, YU-CHUN; ZHANG, FANG-CHENG; WANG, QI; MA, QING-JIU

    2014-01-01

    Surgery for digestive tract disease predominantly consists of reconstruction and anastomosis. Due to the difficult location, anastomosis is extremely challenging and the risk of complication increases accordingly. Traditional manual anastomosis and the application of a stapling device are insufficient. Therefore, the aim of this study was to investigate the feasibility and safety of a novel manual method in a difficult anastomotic location, consisting of a single-layer continuous suture in the posterior wall. In total, 15 beagle dogs were included in the study; eight underwent surgery with the novel manual method for reconstruction and anastomosis of the digestive tract, while seven underwent surgery with the stapler device as a control. The subsequent postoperative complications were observed and, three months later, the anastomotic ports were excised, and the pathological formation and morphological changes were evaluated. No statistically significant differences were identified between the total (50.0 vs. 57.1%; P=0.782) and anastomotic (0.0 vs. 28.6%; P=0.200) complication rates in the manual suture and staple suture groups, respectively. Compared with the control group, the operative expenditure was lower in the manual group (1726.7±33.5 vs. 2135.7±43.1 renminbi; P=0.001), the diameter of the anastomotic port was larger in the manual group (3.04±0.07 vs. 2.24±0.25 cm; P=0.004) and the thickness of the anastomotic port (in cm) was thinner in the manual group (2.94±0.06 vs. 5.07±0.85; P=0.002). Furthermore, the pathological formation of the anastomositic port in the manual group was improved. The results of the current study suggest single-layer continuous suture of the posterior wall in anastomosis of the digestive tract to be a novel method with feasibility and safety, particularly in difficult anastomotic locations. PMID:25202369

  2. Efficacy of single-layer continuous suture of the posterior wall in anastomosis involving a difficult location of the digestive tract.

    PubMed

    Li, Guo-Cai; Xu, Yong; Zhang, Yu-Chun; Zhang, Fang-Cheng; Wang, Qi; Ma, Qing-Jiu

    2014-10-01

    Surgery for digestive tract disease predominantly consists of reconstruction and anastomosis. Due to the difficult location, anastomosis is extremely challenging and the risk of complication increases accordingly. Traditional manual anastomosis and the application of a stapling device are insufficient. Therefore, the aim of this study was to investigate the feasibility and safety of a novel manual method in a difficult anastomotic location, consisting of a single-layer continuous suture in the posterior wall. In total, 15 beagle dogs were included in the study; eight underwent surgery with the novel manual method for reconstruction and anastomosis of the digestive tract, while seven underwent surgery with the stapler device as a control. The subsequent postoperative complications were observed and, three months later, the anastomotic ports were excised, and the pathological formation and morphological changes were evaluated. No statistically significant differences were identified between the total (50.0 vs. 57.1%; P=0.782) and anastomotic (0.0 vs. 28.6%; P=0.200) complication rates in the manual suture and staple suture groups, respectively. Compared with the control group, the operative expenditure was lower in the manual group (1726.7±33.5 vs. 2135.7±43.1 renminbi; P=0.001), the diameter of the anastomotic port was larger in the manual group (3.04±0.07 vs. 2.24±0.25 cm; P=0.004) and the thickness of the anastomotic port (in cm) was thinner in the manual group (2.94±0.06 vs. 5.07±0.85; P=0.002). Furthermore, the pathological formation of the anastomositic port in the manual group was improved. The results of the current study suggest single-layer continuous suture of the posterior wall in anastomosis of the digestive tract to be a novel method with feasibility and safety, particularly in difficult anastomotic locations.

  3. Microscopic Analysis of Plankton, Periphyton, and Activated Sludge. Training Manual.

    ERIC Educational Resources Information Center

    Environmental Protection Agency, Washington, DC. Office of Water Programs.

    This manual is intended for professional personnel in the fields of water pollution control, limnology, water supply and waste treatment. Primary emphasis is given to practice in the identification and enumeration of microscopic organisms which may be encountered in water and activated sludge. Methods for the chemical and instrumental evaluation…

  4. Algorithm design, user interface, and optimization procedure for a fuzzy logic ramp metering algorithm : a training manual for freeway operations engineers

    DOT National Transportation Integrated Search

    2000-02-01

    This training manual describes the fuzzy logic ramp metering algorithm in detail, as implemented system-wide in the greater Seattle area. The method of defining the inputs to the controller and optimizing the performance of the algorithm is explained...

  5. 75 FR 20935 - National Standards for Traffic Control Devices; the Manual on Uniform Traffic Control Devices for...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-04-22

    ... for implementation and continued use of a maintenance method that is designed to maintain pavement... method that is designed to maintain pavement marking retroreflectivity at or above the established levels... every pavement marking in its jurisdiction. Instead, agencies must implement methods designed to provide...

  6. Time series modeling of human operator dynamics in manual control tasks

    NASA Technical Reports Server (NTRS)

    Biezad, D. J.; Schmidt, D. K.

    1984-01-01

    A time-series technique is presented for identifying the dynamic characteristics of the human operator in manual control tasks from relatively short records of experimental data. Control of system excitation signals used in the identification is not required. The approach is a multi-channel identification technique for modeling multi-input/multi-output situations. The method presented includes statistical tests for validity, is designed for digital computation, and yields estimates for the frequency responses of the human operator. A comprehensive relative power analysis may also be performed for validated models. This method is applied to several sets of experimental data; the results are discussed and shown to compare favorably with previous research findings. New results are also presented for a multi-input task that has not been previously modeled to demonstrate the strengths of the method.

  7. Time Series Modeling of Human Operator Dynamics in Manual Control Tasks

    NASA Technical Reports Server (NTRS)

    Biezad, D. J.; Schmidt, D. K.

    1984-01-01

    A time-series technique is presented for identifying the dynamic characteristics of the human operator in manual control tasks from relatively short records of experimental data. Control of system excitation signals used in the identification is not required. The approach is a multi-channel identification technique for modeling multi-input/multi-output situations. The method presented includes statistical tests for validity, is designed for digital computation, and yields estimates for the frequency response of the human operator. A comprehensive relative power analysis may also be performed for validated models. This method is applied to several sets of experimental data; the results are discussed and shown to compare favorably with previous research findings. New results are also presented for a multi-input task that was previously modeled to demonstrate the strengths of the method.

  8. Display aids for remote control of untethered undersea vehicles

    NASA Technical Reports Server (NTRS)

    Verplank, W. L.

    1978-01-01

    A predictor display superimposed on slow-scan video or sonar data is proposed as a method to allow better remote manual control of an untethered submersible. Simulation experiments show good control under circumstances which otherwise make control practically impossible.

  9. [Effect of manual cleaning and machine cleaning for dental handpiece].

    PubMed

    Zhou, Xiaoli; Huang, Hao; He, Xiaoyan; Chen, Hui; Zhou, Xiaoying

    2013-08-01

    Comparing the dental handpiece' s cleaning effect between manual cleaning and machine cleaning. Eighty same contaminated dental handpieces were randomly divided into experimental group and control group, each group contains 40 pieces. The experimental group was treated by full automatic washing machine, and the control group was cleaned manually. The cleaning method was conducted according to the operations process standard, then ATP bioluminescence was used to test the cleaning results. Average relative light units (RLU) by ATP bioluminescence detection were as follows: Experimental group was 9, control group was 41. The two groups were less than the recommended RLU value provided by the instrument manufacturer (RLU < or = 45). There was significant difference between the two groups (P < 0.05). The cleaning quality of the experimental group was better than that of control group. It is recommended that the central sterile supply department should clean dental handpieces by machine to ensure the cleaning effect and maintain the quality.

  10. End-tidal carbon dioxide output in manual cardiopulmonary resuscitation versus active compression-decompression device during prehospital quality controlled resuscitation: a case series study.

    PubMed

    Setälä, Piritta Anniina; Virkkunen, Ilkka Tapani; Kämäräinen, Antti Jaakko; Huhtala, Heini Sisko Annamari; Virta, Janne Severi; Yli-Hankala, Arvi Mikael; Hoppu, Sanna Elisa

    2018-05-16

    Active compression-decompression (ACD) devices have enhanced end-tidal carbon dioxide (ETCO 2 ) output in experimental cardiopulmonary resuscitation (CPR) studies. However, the results in out-of-hospital cardiac arrest (OHCA) patients have shown inconsistent outcomes, and earlier studies lacked quality control of CPR attempts. We compared manual CPR with ACD-CPR by measuring ETCO 2 output using an audiovisual feedback defibrillator to ensure continuous high quality resuscitation attempts. 10 witnessed OHCAs were resuscitated, rotating a 2 min cycle with manual CPR and a 2 min cycle of ACD-CPR. Patients were intubated and the ventilation rate was held constant during CPR. CPR quality parameters and ETCO 2 values were collected continuously with the defibrillator. Differences in ETCO 2 output between manual CPR and ACD-CPR were analysed using a linear mixed model where ETCO 2 output produced by a summary of the 2 min cycles was included as the dependent variable, the patient as a random factor and method as a fixed effect. These comparisons were made within each OHCA case to minimise confounding factors between the cases. Mean length of the CPR episodes was 37 (SD 8) min. Mean compression depth was 76 (SD 1.3) mm versus 71 (SD1.0) mm, and mean compression rate was 100 per min (SD 6.7) versus 105 per min (SD 4.9) between ACD-CPR and manual CPR, respectively. For ETCO 2 output, the interaction between the method and the patient was significant (P<0.001). ETCO 2 output was higher with manual CPR in 6 of the 10 cases. This study suggests that quality controlled ACD-CPR is not superior to quality controlled manual CPR when ETCO 2 is used as a quantitative measure of CPR effectiveness. NCT00951704; Results. © Article author(s) (or their employer(s) unless otherwise stated in the text of the article) 2018. All rights reserved. No commercial use is permitted unless otherwise expressly granted.

  11. Emergency Manuals Improved Novice Physician Performance During Simulated ICU Emergencies

    PubMed Central

    Wang, Jacob; Stiegler, Marjorie P.; Nguyen, Dung; Rebel, Annette; Isaak, Robert S.

    2017-01-01

    Background Emergency manuals, which are safety essentials in non-medical high-reliability organizations (e.g., aviation), have recently gained acceptance in critical medical environments. Of the existing emergency manuals in anesthesiology, most are geared towards intraoperative settings. Additionally, most evidence supporting their efficacy focuses on the study of physicians with at least some meaningful experience as a physician. Our aim was to evaluate whether an emergency manual would improve the performance of novice physicians (post-graduate year [PGY] 1 or first year resident) in managing a critical event in the intensive care unit (ICU). Methods PGY1 interns (n=41) were assessed on the management of a simulated critical event (unstable bradycardia) in the ICU. Participants underwent a group allocation process to either a control group (n=18) or an intervention group (emergency manual provided, n=23). The number of successfully executed treatment and diagnostic interventions completed was evaluated over a ten minute (600 seconds) simulation for each participant. Results The participants using the emergency manual averaged 9.9/12 (83%) interventions, compared to an average of 7.1/12 (59%) interventions (p < 0.01) in the control group. Conclusions The use of an emergency manual was associated with a significant improvement in critical event management by individual novice physicians in a simulated ICU patient (23% average increase). PMID:29600255

  12. Comparison of a brain-based adaptive system and a manual adaptable system for invoking automation.

    PubMed

    Bailey, Nathan R; Scerbo, Mark W; Freeman, Frederick G; Mikulka, Peter J; Scott, Lorissa A

    2006-01-01

    Two experiments are presented examining adaptive and adaptable methods for invoking automation. Empirical investigations of adaptive automation have focused on methods used to invoke automation or on automation-related performance implications. However, no research has addressed whether performance benefits associated with brain-based systems exceed those in which users have control over task allocations. Participants performed monitoring and resource management tasks as well as a tracking task that shifted between automatic and manual modes. In the first experiment, participants worked with an adaptive system that used their electroencephalographic signals to switch the tracking task between automatic and manual modes. Participants were also divided between high- and low-reliability conditions for the system-monitoring task as well as high- and low-complacency potential. For the second experiment, participants operated an adaptable system that gave them manual control over task allocations. Results indicated increased situation awareness (SA) of gauge instrument settings for individuals high in complacency potential using the adaptive system. In addition, participants who had control over automation performed more poorly on the resource management task and reported higher levels of workload. A comparison between systems also revealed enhanced SA of gauge instrument settings and decreased workload in the adaptive condition. The present results suggest that brain-based adaptive automation systems may enhance perceptual level SA while reducing mental workload relative to systems requiring user-initiated control. Potential applications include automated systems for which operator monitoring performance and high-workload conditions are of concern.

  13. Can Dialectical Behavior Therapy Be Learned in Highly Structured Learning Environments? Results from a Randomized Controlled Dissemination Trial

    ERIC Educational Resources Information Center

    Dimeff, Linda A.; Woodcock, Eric A.; Harned, Melanie S.; Beadnell, Blair

    2011-01-01

    This study evaluated the efficacy of methods of training community mental health providers (N=132) in dialectical behavior therapy (DBT) distress tolerance skills, including (a) Linehan's (1993a) Skills Training Manual for Borderline Personality Disorder (Manual), (b) a multimedia e-Learning course covering the same content (e-DBT), and (c) a…

  14. Aquatic Pest Control. Sale Publication 4071.

    ERIC Educational Resources Information Center

    Wamsley, Mary Ann, Ed.; Vermeire, Donna M., Ed.

    The information in this manual applies to control of aquatic pests in recreational waters, agricultural reservoirs, ornamental ponds, coastal bays, estuaries and channels, and drinking water reservoirs. Mechanical, cultural, biological, and chemical control methods are discussed. The majority of the material is devoted to weed control in static…

  15. Three-dimensional echocardiographic measurements using automated quantification software for big data processing.

    PubMed

    Feng, Cheng; Chen, Lixin; Li, Jian; Wang, Jiangtao; Dong, Fajin; Xu, Jinfeng

    2017-01-01

    To compare a full-automated software to quantify 3D transthoracic echocardiography namely, 3DE-HM (three-dimensional echocardiography HeartModel, Philips Healthcare) with the traditional manual quantitative method (3DE-manual) for assessing volumes of left atrial and ventricular volumes, and left ventricular ejection fraction (LVEF). 3D full volume images acquired from 156 subjects were collected and divided into 3 groups, which include 70 normal control cases (Group A), 17 patients with left ventricular remodeling after acute myocardial infarction (AMI) (Group B), and 69 patients with left atrial remodeling secondary to hypertension (Group C). The 3DE-HM method was used to quantify left ventricular end-diastolic volume (LVEDV), left ventricular end-systolic volume (LVESV), left atrial end-systolic volume (LAESV), and left ventricular ejection fraction (LVEF), respectively. The results were compared with those obtained with the 3DE-manual method for correlation and consistency analyses. The reproducibility of the 3DE-HM method was also evaluated. There was a high correlation between LVEDV, LVESV, LAESV and LVEF values obtained with the 3DE-HM method and those obtained using the 3DE-manual method (r = 0.72 to 0.97). The correlation was strongest for Group B, patients with left ventricular remodeling post-AMI also demonstrated the greatest degree of morphologic changes. There was a significant difference in all parameters measured with the 3DE-HM method in different groups (P < 0.05). The difference in the measurements of LVEDV and LVESV between the two methods was greatest in patients in Group B compared with patients with hypertension-induced left ventricular remodeling (Group C) and in normal controls (Group A) (P < 0.05). Lastly, the difference in the measurement of LAESV between the two methods was greater in patients with hypertension-induced left ventricular remodeling (Group C) than that in the control group (Group A) (P < 0.05). The post-processing time of the 3DE-HM data was significantly shorter than that using the 3DE-manual method (P < 0.05). There was no significant variability in repeated measurements at different time points using the 3DE-HM method either between subjects in different groups or within the same subject. 3DE-HM is a quick and feasible method for left ventricular quantification and is clinically applicable for evaluating patients with left atrial and left ventricular remodeling.

  16. Guidelines for Analysis of Communicable Disease Control Planning in Developing Countries. Volume 1: Communicable Diseases Control Planning. International Health Planning Methods Series.

    ERIC Educational Resources Information Center

    Chin, James

    Intended to assist Agency for International Development (AID) officers, advisors, and health officials in incorporating health planning into national plans for economic development, this first of ten manuals in the International Health Planning Methods Series deals with planning and evaluation of communicable disease control programs. The first…

  17. Monitoring of endoscope reprocessing with an adenosine triphosphate (ATP) bioluminescence method.

    PubMed

    Parohl, Nina; Stiefenhöfer, Doris; Heiligtag, Sabine; Reuter, Henning; Dopadlik, Dana; Mosel, Frank; Gerken, Guido; Dechêne, Alexander; Heintschel von Heinegg, Evelyn; Jochum, Christoph; Buer, Jan; Popp, Walter

    2017-01-01

    Background: The arising challenges over endoscope reprocessing quality proposes to look for possibilities to measure and control the process of endoscope reprocessing. Aim: The goal of this study was to evaluate the feasibility of monitoring endoscope reprocessing with an adenosine triphosphate (ATP) based bioluminescence system. Methods: 60 samples of eight gastroscopes have been assessed from routine clinical use in a major university hospital in Germany. Endoscopes have been assessed with an ATP system and microbial cultures at different timepoints during the reprocessing. Findings: After the bedside flush the mean ATP level in relative light units (RLU) was 19,437 RLU, after the manual cleaning 667 RLU and after the automated endoscope reprocessor (AER) 227 RLU. After the manual cleaning the mean total viable count (TVC) per endoscope was 15.3 CFU/10 ml, and after the AER 5.7 CFU/10 ml. Our results show that there are reprocessing cycles which are not able to clean a patient used endoscope. Conclusion: Our data suggest that monitoring of flexible endoscope with ATP can identify a number of different influence factors, like the endoscope condition and the endoscopic procedure, or especially the quality of the bedside flush and manual cleaning before the AER. More process control is one option to identify and improve influence factors to finally increase the overall reprocessing quality, best of all by different methods. ATP measurement seems to be a valid technique that allows an immediate repeat of the manual cleaning if the ATP results after manual cleaning exceed the established cutoff of 200 RLU.

  18. Assessment of Alternative Interfaces for Manual Commanding of Spacecraft Systems: Compatibility with Flexible Allocation Policies

    NASA Technical Reports Server (NTRS)

    Billman, Dorrit Owen; Schreckenghost, Debra; Miri, Pardis

    2014-01-01

    Astronauts will be responsible for executing a much larger body of procedures as human exploration moves further from Earth and Mission Control. Efficient, reliable methods for executing these procedures, including manual, automated, and mixed execution will be important. Our interface integrates step-by-step instruction with the means for execution. The research reported here compared manual execution using the new system to a system analogous to the manual-only system currently in use on the International Space Station, to assess whether user performance in manual operations would be as good or better with the new than with the legacy system. The system used also allows flexible automated execution. The system and our data lay the foundation for integrating automated execution into the flow of procedures designed for humans. In our formative study, we found speed and accuracy of manual procedure execution was better using the new, integrated interface over the legacy design.

  19. Comparison of manual and homogenizer methods for preparation of tick-derived stabilates of Theileria parva: equivalence testing using an in vitro titration model.

    PubMed

    Mbao, V; Speybroeck, N; Berkvens, D; Dolan, T; Dorny, P; Madder, M; Mulumba, M; Duchateau, L; Brandt, J; Marcotty, T

    2005-07-01

    Theileria parva sporozoite stabilates are used in the infection and treatment method of immunization, a widely accepted control option for East Coast fever in cattle. T. parva sporozoites are extracted from infected adult Rhipicephalus appendiculatus ticks either manually, using a pestle and a mortar, or by use of an electric homogenizer. A comparison of the two methods as a function of stabilate infectivity has never been documented. This study was designed to provide a quantitative comparison of stabilates produced by the two methods. The approach was to prepare batches of stabilate by both methods and then subject them to in vitro titration. Equivalence testing was then performed on the average effective doses (ED). The ratio of infective sporozoites yielded by the two methods was found to be 1.14 in favour of the manually ground stabilate with an upper limit of the 95% confidence interval equal to 1.3. We conclude that the choice of method rests more on costs, available infrastructure and standardization than on which method produces a richer sporozoite stabilate.

  20. Application of Digital Image Analysis to Determine Pancreatic Islet Mass and Purity in Clinical Islet Isolation and Transplantation

    PubMed Central

    Wang, Ling-jia; Kissler, Hermann J; Wang, Xiaojun; Cochet, Olivia; Krzystyniak, Adam; Misawa, Ryosuke; Golab, Karolina; Tibudan, Martin; Grzanka, Jakub; Savari, Omid; Grose, Randall; Kaufman, Dixon B; Millis, Michael; Witkowski, Piotr

    2015-01-01

    Pancreatic islet mass, represented by islet equivalent (IEQ), is the most important parameter in decision making for clinical islet transplantation. To obtain IEQ, the sample of islets is routinely counted manually under a microscope and discarded thereafter. Islet purity, another parameter in islet processing, is routinely acquired by estimation only. In this study, we validated our digital image analysis (DIA) system developed using the software of Image Pro Plus for islet mass and purity assessment. Application of the DIA allows to better comply with current good manufacturing practice (cGMP) standards. Human islet samples were captured as calibrated digital images for the permanent record. Five trained technicians participated in determination of IEQ and purity by manual counting method and DIA. IEQ count showed statistically significant correlations between the manual method and DIA in all sample comparisons (r >0.819 and p < 0.0001). Statistically significant difference in IEQ between both methods was found only in High purity 100μL sample group (p = 0.029). As far as purity determination, statistically significant differences between manual assessment and DIA measurement was found in High and Low purity 100μL samples (p<0.005), In addition, islet particle number (IPN) and the IEQ/IPN ratio did not differ statistically between manual counting method and DIA. In conclusion, the DIA used in this study is a reliable technique in determination of IEQ and purity. Islet sample preserved as a digital image and results produced by DIA can be permanently stored for verification, technical training and islet information exchange between different islet centers. Therefore, DIA complies better with cGMP requirements than the manual counting method. We propose DIA as a quality control tool to supplement the established standard manual method for islets counting and purity estimation. PMID:24806436

  1. 46 CFR 62.25-10 - Manual alternate control systems.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... automatic primary control system failure; (2) Be suitable for manual control for prolonged periods; (3) Be... 46 Shipping 2 2011-10-01 2011-10-01 false Manual alternate control systems. 62.25-10 Section 62.25... AUTOMATION General Requirements for All Automated Vital Systems § 62.25-10 Manual alternate control systems...

  2. An introduction to high speed aircraft noise prediction

    NASA Technical Reports Server (NTRS)

    Wilson, Mark R.

    1992-01-01

    The Aircraft Noise Prediction Program's High Speed Research prediction system (ANOPP-HSR) is introduced. This mini-manual is an introduction which gives a brief overview of the ANOPP system and the components of the HSR prediction method. ANOPP information resources are given. Twelve of the most common ANOPP-HSR control statements are described. Each control statement's purpose and format are stated and relevant examples are provided. More detailed examples of the use of the control statements are presented in the manual along with ten ANOPP-HSR templates. The purpose of the templates is to provide the user with working ANOPP-HSR programs which can be modified to serve particular prediction requirements. Also included in this manual is a brief discussion of common errors and how to solve these problems. The appendices include the following useful information: a summary of all ANOPP-HSR functional research modules, a data unit directory, a discussion of one of the more complex control statements, and input data unit and table examples.

  3. Comparison of human septal nuclei MRI measurements using automated segmentation and a new manual protocol based on histology

    PubMed Central

    Butler, Tracy; Zaborszky, Laszlo; Pirraglia, Elizabeth; Li, Jinyu; Wang, Xiuyuan Hugh; Li, Yi; Tsui, Wai; Talos, Delia; Devinsky, Orrin; Kuchna, Izabela; Nowicki, Krzysztof; French, Jacqueline; Kuzniecky, Rubin; Wegiel, Jerzy; Glodzik, Lidia; Rusinek, Henry; DeLeon, Mony J.; Thesen, Thomas

    2014-01-01

    Septal nuclei, located in basal forebrain, are strongly connected with hippocampi and important in learning and memory, but have received limited research attention in human MRI studies. While probabilistic maps for estimating septal volume on MRI are now available, they have not been independently validated against manual tracing of MRI, typically considered the gold standard for delineating brain structures. We developed a protocol for manual tracing of the human septal region on MRI based on examination of neuroanatomical specimens. We applied this tracing protocol to T1 MRI scans (n=86) from subjects with temporal epilepsy and healthy controls to measure septal volume. To assess the inter-rater reliability of the protocol, a second tracer used the same protocol on 20 scans that were randomly selected from the 72 healthy controls. In addition to measuring septal volume, maximum septal thickness between the ventricles was measured and recorded. The same scans (n=86) were also analysed using septal probabilistic maps and Dartel toolbox in SPM. Results show that our manual tracing algorithm is reliable, and that septal volume measurements obtained via manual and automated methods correlate significantly with each other (p<001). Both manual and automated methods detected significantly enlarged septal nuclei in patients with temporal lobe epilepsy in accord with a proposed compensatory neuroplastic process related to the strong connections between septal nuclei and hippocampi. Septal thickness, which was simple to measure with excellent inter-rater reliability, correlated well with both manual and automated septal volume, suggesting it could serve as an easy-to-measure surrogate for septal volume in future studies. Our results call attention to the important though understudied human septal region, confirm its enlargement in temporal lobe epilepsy, and provide a reliable new manual delineation protocol that will facilitate continued study of this critical region. PMID:24736183

  4. Comparison of human septal nuclei MRI measurements using automated segmentation and a new manual protocol based on histology.

    PubMed

    Butler, Tracy; Zaborszky, Laszlo; Pirraglia, Elizabeth; Li, Jinyu; Wang, Xiuyuan Hugh; Li, Yi; Tsui, Wai; Talos, Delia; Devinsky, Orrin; Kuchna, Izabela; Nowicki, Krzysztof; French, Jacqueline; Kuzniecky, Rubin; Wegiel, Jerzy; Glodzik, Lidia; Rusinek, Henry; deLeon, Mony J; Thesen, Thomas

    2014-08-15

    Septal nuclei, located in basal forebrain, are strongly connected with hippocampi and important in learning and memory, but have received limited research attention in human MRI studies. While probabilistic maps for estimating septal volume on MRI are now available, they have not been independently validated against manual tracing of MRI, typically considered the gold standard for delineating brain structures. We developed a protocol for manual tracing of the human septal region on MRI based on examination of neuroanatomical specimens. We applied this tracing protocol to T1 MRI scans (n=86) from subjects with temporal epilepsy and healthy controls to measure septal volume. To assess the inter-rater reliability of the protocol, a second tracer used the same protocol on 20 scans that were randomly selected from the 72 healthy controls. In addition to measuring septal volume, maximum septal thickness between the ventricles was measured and recorded. The same scans (n=86) were also analyzed using septal probabilistic maps and DARTEL toolbox in SPM. Results show that our manual tracing algorithm is reliable, and that septal volume measurements obtained via manual and automated methods correlate significantly with each other (p<.001). Both manual and automated methods detected significantly enlarged septal nuclei in patients with temporal lobe epilepsy in accord with a proposed compensatory neuroplastic process related to the strong connections between septal nuclei and hippocampi. Septal thickness, which was simple to measure with excellent inter-rater reliability, correlated well with both manual and automated septal volume, suggesting it could serve as an easy-to-measure surrogate for septal volume in future studies. Our results call attention to the important though understudied human septal region, confirm its enlargement in temporal lobe epilepsy, and provide a reliable new manual delineation protocol that will facilitate continued study of this critical region. Copyright © 2014 Elsevier Inc. All rights reserved.

  5. 40 CFR 63.4965 - How do I determine the add-on control device emission destruction or removal efficiency?

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... an alternative to Method 3B, the manual method for measuring the oxygen, carbon dioxide, and carbon..., Instruments and Apparatus]” (incorporated by reference, see § 63.14). (4) Use Method 4 of appendix A to 40 CFR... total gaseous organic mass emissions as carbon at the inlet and outlet of the add-on control device...

  6. 40 CFR 63.3545 - How do I determine the add-on control device emission destruction or removal efficiency?

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... an alternative to Method 3B the manual method for measuring the oxygen, carbon dioxide, and carbon..., Instruments and Apparatus]” (incorporated by reference, see § 63.14). (4) Use Method 4 of appendix A to 40 CFR... total gaseous organic mass emissions as carbon at the inlet and outlet of the add-on control device...

  7. Quality control in urinalysis.

    PubMed

    Takubo, T; Tatsumi, N

    1999-01-01

    Quality control (QC) has been introduced in laboratories, and QC surveys in urinalysis have been performed by College of American Pathologist, by Japanese Association of Medical Technologists, by Osaka Medical Association and by manufacturers. QC survey in urinalysis for synthetic urine by the reagent strip and instrument made in same manufacturer, and by an automated urine cell analyser provided satisfactory results among laboratories. QC survey in urinalysis for synthetic urine by the reagent strips and instruments made by various manufacturers indicated differences in the determination values among manufacturers, and between manual and automated methods because the reagent strips and instruments have different characteristics, respectively. QC photo survey in urinalysis on the microscopic photos of urine sediment constituents indicated differences in the identification of cells among laboratories. From the results, it is necessary to standardize a reagent strip method, manual and automated methods, and synthetic urine.

  8. Applying Computer Models to Realize Closed-Loop Neonatal Oxygen Therapy.

    PubMed

    Morozoff, Edmund; Smyth, John A; Saif, Mehrdad

    2017-01-01

    Within the context of automating neonatal oxygen therapy, this article describes the transformation of an idea verified by a computer model into a device actuated by a computer model. Computer modeling of an entire neonatal oxygen therapy system can facilitate the development of closed-loop control algorithms by providing a verification platform and speeding up algorithm development. In this article, we present a method of mathematically modeling the system's components: the oxygen transport within the patient, the oxygen blender, the controller, and the pulse oximeter. Furthermore, within the constraints of engineering a product, an idealized model of the neonatal oxygen transport component may be integrated effectively into the control algorithm of a device, referred to as the adaptive model. Manual and closed-loop oxygen therapy performance were defined in this article by 3 criteria in the following order of importance: percent duration of SpO2 spent in normoxemia (target SpO2 ± 2.5%), hypoxemia (less than normoxemia), and hyperoxemia (more than normoxemia); number of 60-second periods <85% SpO2 and >95% SpO2; and number of manual adjustments. Results from a clinical evaluation that compared the performance of 3 closed-loop control algorithms (state machine, proportional-integral-differential, and adaptive model) with manual oxygen therapy on 7 low-birth-weight ventilated preterm babies, are presented. Compared with manual therapy, all closed-loop control algorithms significantly increased the patients' duration in normoxemia and reduced hyperoxemia (P < 0.05). The number of manual adjustments was also significantly reduced by all of the closed-loop control algorithms (P < 0.05). Although the performance of the 3 control algorithms was equivalent, it is suggested that the adaptive model, with its ease of use, may have the best utility.

  9. Method and apparatus for telemetry adaptive bandwidth compression

    NASA Technical Reports Server (NTRS)

    Graham, Olin L.

    1987-01-01

    Methods and apparatus are provided for automatic and/or manual adaptive bandwidth compression of telemetry. An adaptive sampler samples a video signal from a scanning sensor and generates a sequence of sampled fields. Each field and range rate information from the sensor are hence sequentially transmitted to and stored in a multiple and adaptive field storage means. The field storage means then, in response to an automatic or manual control signal, transfers the stored sampled field signals to a video monitor in a form for sequential or simultaneous display of a desired number of stored signal fields. The sampling ratio of the adaptive sample, the relative proportion of available communication bandwidth allocated respectively to transmitted data and video information, and the number of fields simultaneously displayed are manually or automatically selectively adjustable in functional relationship to each other and detected range rate. In one embodiment, when relatively little or no scene motion is detected, the control signal maximizes sampling ratio and causes simultaneous display of all stored fields, thus maximizing resolution and bandwidth available for data transmission. When increased scene motion is detected, the control signal is adjusted accordingly to cause display of fewer fields. If greater resolution is desired, the control signal is adjusted to increase the sampling ratio.

  10. On-line moisture determination of ore concentrates 'a review of traditional methods and introduction of a novel solution'.

    PubMed

    Cancilla, P A; Barrette, P; Rosenblum, F

    2002-12-01

    The manual gravimetric drying moisture determination methods currently employed by most mineral processing plants fail to provide timely and accurate information required for automatic control. The costs associated with transporting and handling concentrates still represent a major portion of the overall treatment price. When considering the cash flow of a mining operation that is governed by both the smelter contract, with moisture penalties and the quantity and quality of the concentrates shipped, an efficient method of on-line moisture content would be a welcome tool. A novel on-line determination system for ore concentrate moisture content would replace the tedious manual procedure. Since the introduction of microelectronic-based control systems, operators have strived to reduce the treatment costs to the minimum. Therefore, a representative and timely determination of on-line moisture content becomes vital for control set points and timely feedback. Reliable sensors have long been on the 'wish list' of mineral processors since the problem has always been that you can only control what you can measure. Today, the task of moisture determination is still done by the classical technique of loss in weight utilizing uncontrolled procedures. These same methods were introduced in the earliest base metal concentrators. Generally, it is acceptable to have ore concentrate moisture content vary within a range of 7-9%, but controlling the moisture content below 8% is a difficult task with a manually controlled system. Many times, delays in manually achieving reliable feedback of the moisture content results in the moisture varying from 5-12% before corrective actions can be made. This paper first reviews the traditional and widely available methods for determining moisture content in granular materials by applying physical principles and properties to measure moisture content. All methods are in some form affected when employed on mineral ore concentrates. This paper introduces and describes a novel on-line moisture sensor employed for mineral processing de-watering applications, which not only automates the tedious tasks but also results in reliable moisture feedback that can be used in the optimization of the de-watering process equipment such as pressure or vacuum filters and fuel-fired driers. Finally, two measurement applications will be presented which indicate the usefulness and summarizes the measurement requirements for the proposed method of employing drag force and mechanical properties of the material itself to determine the moisture content. Copyright 2002 Elsevier Science Ltd.

  11. First evaluation of automated specimen inoculation for wound swab samples by use of the Previ Isola system compared to manual inoculation in a routine laboratory: finding a cost-effective and accurate approach.

    PubMed

    Mischnik, Alexander; Mieth, Markus; Busch, Cornelius J; Hofer, Stefan; Zimmermann, Stefan

    2012-08-01

    Automation of plate streaking is ongoing in clinical microbiological laboratories, but evaluation for routine use is mostly open. In the present study, the recovery of microorganisms from the Previ Isola system plated polyurethane (PU) swab samples is compared to manually plated control viscose swab samples from wounds according to the CLSI procedure M40-A (quality control of microbiological transport systems). One hundred twelve paired samples (224 swabs) were analyzed. In 80/112 samples (71%), concordant culture results were obtained with the two methods. In 32/112 samples (29%), CFU recovery of microorganisms from the two methods was discordant. In 24 (75%) of the 32 paired samples with a discordant result, Previ Isola plated PU swabs were superior. In 8 (25%) of the 32 paired samples with a discordant result, control viscose swabs were superior. The quality of colony growth on culture media for further investigations was superior with Previ Isola inoculated plates compared to manual plating techniques. Gram stain results were concordant between the two methods in 62/112 samples (55%). In 50/112 samples (45%), the results of Gram staining were discordant between the two methods. In 34 (68%) of the 50 paired samples with discordant results, Gram staining of PU swabs was superior to that of control viscose swabs. In 16 (32%) of the 50 paired samples, Gram staining of control viscose swabs was superior to that of PU swabs. We report the first clinical evaluation of Previ Isola automated specimen inoculation for wound swab samples. This study suggests that use of an automated specimen inoculation system has good results with regard to CFU recovery, quality of Gram staining, and accuracy of diagnosis.

  12. First Evaluation of Automated Specimen Inoculation for Wound Swab Samples by Use of the Previ Isola System Compared to Manual Inoculation in a Routine Laboratory: Finding a Cost-Effective and Accurate Approach

    PubMed Central

    Mieth, Markus; Busch, Cornelius J.; Hofer, Stefan; Zimmermann, Stefan

    2012-01-01

    Automation of plate streaking is ongoing in clinical microbiological laboratories, but evaluation for routine use is mostly open. In the present study, the recovery of microorganisms from the Previ Isola system plated polyurethane (PU) swab samples is compared to manually plated control viscose swab samples from wounds according to the CLSI procedure M40-A (quality control of microbiological transport systems). One hundred twelve paired samples (224 swabs) were analyzed. In 80/112 samples (71%), concordant culture results were obtained with the two methods. In 32/112 samples (29%), CFU recovery of microorganisms from the two methods was discordant. In 24 (75%) of the 32 paired samples with a discordant result, Previ Isola plated PU swabs were superior. In 8 (25%) of the 32 paired samples with a discordant result, control viscose swabs were superior. The quality of colony growth on culture media for further investigations was superior with Previ Isola inoculated plates compared to manual plating techniques. Gram stain results were concordant between the two methods in 62/112 samples (55%). In 50/112 samples (45%), the results of Gram staining were discordant between the two methods. In 34 (68%) of the 50 paired samples with discordant results, Gram staining of PU swabs was superior to that of control viscose swabs. In 16 (32%) of the 50 paired samples, Gram staining of control viscose swabs was superior to that of PU swabs. We report the first clinical evaluation of Previ Isola automated specimen inoculation for wound swab samples. This study suggests that use of an automated specimen inoculation system has good results with regard to CFU recovery, quality of Gram staining, and accuracy of diagnosis. PMID:22692745

  13. Lawn and Turf Pest Control: A Guide for Commercial Applicators.

    ERIC Educational Resources Information Center

    Khan, M. S.

    This manual is designed for use in training commercial pesticide applicators. It gives identification and control information for common lawn and turf diseases, insects, nematodes, weeds, and vertebrate pests. It also discusses phytotoxicity, environmental concerns, and application methods. (BB)

  14. Right-of-Way Pest Control. Sale Publication 4075.

    ERIC Educational Resources Information Center

    Stimmann, M. W., Ed.

    This manual discusses weed control to be applied to such areas as roads, airports, railroads, electric utilities, waterways; and trails. Included is information about types of weeds, methods of weed control, safe and effective use of herbicides, and application equipment. Some topics included are: (1) selective and nonselective herbicides; (2)…

  15. Applications of "Integrated Data Viewer'' (IDV) in the classroom

    NASA Astrophysics Data System (ADS)

    Nogueira, R.; Cutrim, E. M.

    2006-06-01

    Conventionally, weather products utilized in synoptic meteorology reduce phenomena occurring in four dimensions to a 2-dimensional form. This constitutes a road-block for non-atmospheric-science majors who need to take meteorology as a non-mathematical and complementary course to their major programs. This research examines the use of Integrated Data Viewer-IDV as a teaching tool, as it allows a 4-dimensional representation of weather products. IDV was tested in the teaching of synoptic meteorology, weather analysis, and weather map interpretation to non-science students in the laboratory sessions of an introductory meteorology class at Western Michigan University. Comparison of student exam scores according to the laboratory teaching techniques, i.e., traditional lab manual and IDV was performed for short- and long-term learning. Results of the statistical analysis show that the Fall 2004 students in the IDV-based lab session retained learning. However, in the Spring 2005 the exam scores did not reflect retention in learning when compared with IDV-based and MANUAL-based lab scores (short term learning, i.e., exam taken one week after the lab exercise). Testing the long-term learning, seven weeks between the two exams in the Spring 2005, show no statistically significant difference between IDV-based group scores and MANUAL-based group scores. However, the IDV group obtained exam score average slightly higher than the MANUAL group. Statistical testing of the principal hypothesis in this study, leads to the conclusion that the IDV-based method did not prove to be a better teaching tool than the traditional paper-based method. Future studies could potentially find significant differences in the effectiveness of both manual and IDV methods if the conditions had been more controlled. That is, students in the control group should not be exposed to the weather analysis using IDV during lecture.

  16. Improving transcriptome construction in non-model organisms: integrating manual and automated gene definition in Emiliania huxleyi.

    PubMed

    Feldmesser, Ester; Rosenwasser, Shilo; Vardi, Assaf; Ben-Dor, Shifra

    2014-02-22

    The advent of Next Generation Sequencing technologies and corresponding bioinformatics tools allows the definition of transcriptomes in non-model organisms. Non-model organisms are of great ecological and biotechnological significance, and consequently the understanding of their unique metabolic pathways is essential. Several methods that integrate de novo assembly with genome-based assembly have been proposed. Yet, there are many open challenges in defining genes, particularly where genomes are not available or incomplete. Despite the large numbers of transcriptome assemblies that have been performed, quality control of the transcript building process, particularly on the protein level, is rarely performed if ever. To test and improve the quality of the automated transcriptome reconstruction, we used manually defined and curated genes, several of them experimentally validated. Several approaches to transcript construction were utilized, based on the available data: a draft genome, high quality RNAseq reads, and ESTs. In order to maximize the contribution of the various data, we integrated methods including de novo and genome based assembly, as well as EST clustering. After each step a set of manually curated genes was used for quality assessment of the transcripts. The interplay between the automated pipeline and the quality control indicated which additional processes were required to improve the transcriptome reconstruction. We discovered that E. huxleyi has a very high percentage of non-canonical splice junctions, and relatively high rates of intron retention, which caused unique issues with the currently available tools. While individual tools missed genes and artificially joined overlapping transcripts, combining the results of several tools improved the completeness and quality considerably. The final collection, created from the integration of several quality control and improvement rounds, was compared to the manually defined set both on the DNA and protein levels, and resulted in an improvement of 20% versus any of the read-based approaches alone. To the best of our knowledge, this is the first time that an automated transcript definition is subjected to quality control using manually defined and curated genes and thereafter the process is improved. We recommend using a set of manually curated genes to troubleshoot transcriptome reconstruction.

  17. A comparison of the efficacy of powered and manual toothbrushes in controlling plaque and gingivitis: a clinical study

    PubMed Central

    Jain, Yashika

    2013-01-01

    Background Plaque is intimately related to the production and progress of dental caries and inflammatory gingival and periodontal diseases. Good plaque control facilitates the return to health for patients with gingival and periodontal diseases. Daily use of a toothbrush and other oral hygiene aids is the most dependable way to achieve oral health benefits for all patients. Methods A randomized clinical trial was conducted to compare the efficacy of a powered toothbrush with a manual toothbrush in controlling plaque and gingivitis over a 6-week period. The sample consisted of 60 dental students of both sexes, with ages ranging from 18 to 28 years. The samples were stratified and randomly divided into two groups of 30 by a second examiner using the coin toss method; one group used a manual toothbrush and the other group used a powered toothbrush. Each participant’s gingival index, plaque index and oral hygiene index were assessed on the seventh, 14th, and 45th days on the basis of the assigned toothbrush. Collected data were analyzed and different subgroups were compared using Student’s t-test. Results A paired t-test revealed a highly significant reduction in the gingival, plaque, and oral hygiene index scores of the manual and powered groups at the first, second, and sixth weeks (P-value < 0.0001). An unpaired t-test revealed a significant reduction between the plaque index scores of the manual and powered groups at the second week (P-value < 0.05). Another unpaired t-test revealed a highly significant reduction between the plaque index scores of the manual and powered groups at the sixth week (P-value < 0.0001). Conclusion The subject group using the powered toothbrush demonstrated clinical and statistical improvement in overall plaque scores. Powered toothbrushes offer an individual the ability to brush the teeth in a way that is optimal in terms of removing plaque and improving gingival health, conferring good brushing technique on all who use them, irrespective of manual dexterity or training. PMID:23674927

  18. ISS Contingency Attitude Control Recovery Method for Loss of Automatic Thruster Control

    NASA Technical Reports Server (NTRS)

    Bedrossian, Nazareth; Bhatt, Sagar; Alaniz, Abran; McCants, Edward; Nguyen, Louis; Chamitoff, Greg

    2008-01-01

    In this paper, the attitude control issues associated with International Space Station (ISS) loss of automatic thruster control capability are discussed and methods for attitude control recovery are presented. This scenario was experienced recently during Shuttle mission STS-117 and ISS Stage 13A in June 2007 when the Russian GN&C computers, which command the ISS thrusters, failed. Without automatic propulsive attitude control, the ISS would not be able to regain attitude control after the Orbiter undocked. The core issues associated with recovering long-term attitude control using CMGs are described as well as the systems engineering analysis to identify recovery options. It is shown that the recovery method can be separated into a procedure for rate damping to a safe harbor gravity gradient stable orientation and a capability to maneuver the vehicle to the necessary initial conditions for long term attitude hold. A manual control option using Soyuz and Progress vehicle thrusters is investigated for rate damping and maneuvers. The issues with implementing such an option are presented and the key issue of closed-loop stability is addressed. A new non-propulsive alternative to thruster control, Zero Propellant Maneuver (ZPM) attitude control method is introduced and its rate damping and maneuver performance evaluated. It is shown that ZPM can meet the tight attitude and rate error tolerances needed for long term attitude control. A combination of manual thruster rate damping to a safe harbor attitude followed by a ZPM to Stage long term attitude control orientation was selected by the Anomaly Resolution Team as the alternate attitude control method for such a contingency.

  19. Influence of Vibrotactile Feedback on Controlling Tilt Motion After Spaceflight

    NASA Technical Reports Server (NTRS)

    Wood, S. J.; Rupert, A. H.; Vanya, R. D.; Esteves, J. T.; Clement, G.

    2011-01-01

    We hypothesize that adaptive changes in how inertial cues from the vestibular system are integrated with other sensory information leads to perceptual disturbances and impaired manual control following transitions between gravity environments. The primary goals of this ongoing post-flight investigation are to quantify decrements in manual control of tilt motion following short-duration spaceflight and to evaluate vibrotactile feedback of tilt as a sensorimotor countermeasure. METHODS. Data is currently being collected on 9 astronaut subjects during 3 preflight sessions and during the first 8 days after Shuttle landings. Variable radius centrifugation (216 deg/s, <20 cm radius) in a darkened room is utilized to elicit otolith reflexes in the lateral plane without concordant canal or visual cues. A Tilt-Translation Sled (TTS) is capable of synchronizing pitch tilt with fore-aft translation to align the resultant gravitoinertial vector with the longitudinal body axis, thereby eliciting canal reflexes without concordant otolith or visual cues. A simple 4 tactor system was implemented to provide feedback when tilt position exceeded predetermined levels in either device. Closed-loop nulling tasks are performed during random tilt steps or sum-of-sines (TTS only) with and without vibrotactile feedback of chair position. RESULTS. On landing day the manual control performance without vibrotactile feedback was reduced by >30% based on the gain or the amount of tilt disturbance successfully nulled. Manual control performance tended to return to baseline levels within 1-2 days following landing. Root-mean-square position error and tilt velocity were significantly reduced with vibrotactile feedback. CONCLUSIONS. These preliminary results are consistent with our hypothesis that adaptive changes in vestibular processing corresponds to reduced manual control performance following G-transitions. A simple vibrotactile prosthesis improves the ability to null out tilt motion within a limited range of motion disturbances.

  20. Hippocampal volume change measurement: quantitative assessment of the reproducibility of expert manual outlining and the automated methods FreeSurfer and FIRST.

    PubMed

    Mulder, Emma R; de Jong, Remko A; Knol, Dirk L; van Schijndel, Ronald A; Cover, Keith S; Visser, Pieter J; Barkhof, Frederik; Vrenken, Hugo

    2014-05-15

    To measure hippocampal volume change in Alzheimer's disease (AD) or mild cognitive impairment (MCI), expert manual delineation is often used because of its supposed accuracy. It has been suggested that expert outlining yields poorer reproducibility as compared to automated methods, but this has not been investigated. To determine the reproducibilities of expert manual outlining and two common automated methods for measuring hippocampal atrophy rates in healthy aging, MCI and AD. From the Alzheimer's Disease Neuroimaging Initiative (ADNI), 80 subjects were selected: 20 patients with AD, 40 patients with mild cognitive impairment (MCI) and 20 healthy controls (HCs). Left and right hippocampal volume change between baseline and month-12 visit was assessed by using expert manual delineation, and by the automated software packages FreeSurfer (longitudinal processing stream) and FIRST. To assess reproducibility of the measured hippocampal volume change, both back-to-back (BTB) MPRAGE scans available for each visit were analyzed. Hippocampal volume change was expressed in μL, and as a percentage of baseline volume. Reproducibility of the 1-year hippocampal volume change was estimated from the BTB measurements by using linear mixed model to calculate the limits of agreement (LoA) of each method, reflecting its measurement uncertainty. Using the delta method, approximate p-values were calculated for the pairwise comparisons between methods. Statistical analyses were performed both with inclusion and exclusion of visibly incorrect segmentations. Visibly incorrect automated segmentation in either one or both scans of a longitudinal scan pair occurred in 7.5% of the hippocampi for FreeSurfer and in 6.9% of the hippocampi for FIRST. After excluding these failed cases, reproducibility analysis for 1-year percentage volume change yielded LoA of ±7.2% for FreeSurfer, ±9.7% for expert manual delineation, and ±10.0% for FIRST. Methods ranked the same for reproducibility of 1-year μL volume change, with LoA of ±218 μL for FreeSurfer, ±319 μL for expert manual delineation, and ±333 μL for FIRST. Approximate p-values indicated that reproducibility was better for FreeSurfer than for manual or FIRST, and that manual and FIRST did not differ. Inclusion of failed automated segmentations led to worsening of reproducibility of both automated methods for 1-year raw and percentage volume change. Quantitative reproducibility values of 1-year microliter and percentage hippocampal volume change were roughly similar between expert manual outlining, FIRST and FreeSurfer, but FreeSurfer reproducibility was statistically significantly superior to both manual outlining and FIRST after exclusion of failed segmentations. Copyright © 2014 Elsevier Inc. All rights reserved.

  1. Precise Evaluation of Anthropometric 2D Software Processing of Hand in Comparison with Direct Method

    PubMed Central

    Habibi, Ehsanollah; Soury, Shiva; Zadeh, Akbar Hasan

    2013-01-01

    Various studies carried out on different photo anthropometry, but each one had some deficiencies which during the years they have been resolved. The objective of this paper is to test the efficiency of two-dimensional image processing software in photo anthropometry of hand. In this applied research, 204 office workers and industrial workers were selected. Their hands were measured by manual with photo anthropometric methods. In this study, designing the “Hand Photo Anthropometry Set,” we tried to fix the angle and distance of the camera in all of the photos. Thus, some of the common mistakes in photo anthropometric method got controlled. The taken photos were analyzed by Digimizer software, version 4.1.1.0 and Digital Caliper (Model: Mitutoyo Corp., Tokyo, Japan) was used via manual method. t-test statistical test on data revealed that there is no significant difference between the manual and photo anthropometric results (P > 0.05) and the correlation coefficients for hand dimensions are similar in both methods illustrated in the range of 0.71-0.95. The statistical analyses showed that photo anthropometry can be replaced with manual methods. Furthermore, it can provide a great help to develop an anthropometric database for work gloves manufacturers. Since the hand anthropometry is a necessary input for tool design, this survey can be used to determine the percentiles of workers’ hands. PMID:24696802

  2. Disinfection of transvaginal ultrasound probes in a clinical setting: comparative performance of automated and manual reprocessing methods.

    PubMed

    Buescher, D L; Möllers, M; Falkenberg, M K; Amler, S; Kipp, F; Burdach, J; Klockenbusch, W; Schmitz, R

    2016-05-01

    Transvaginal and intracavitary ultrasound probes are a possible source of cross-contamination with microorganisms and thus a risk to patients' health. Therefore appropriate methods for reprocessing are needed. This study was designed to compare the standard disinfection method for transvaginal ultrasound probes in Germany with an automated disinfection method in a clinical setting. This was a prospective randomized controlled clinical study of two groups. In each group, 120 microbial samples were collected from ultrasound transducers before and after disinfection with either an automated method (Trophon EPR®) or a manual method (Mikrozid Sensitive® wipes). Samples were then analyzed for microbial growth and isolates were identified to species level. Automated disinfection had a statistically significantly higher success rate of 91.4% (106/116) compared with 78.8% (89/113) for manual disinfection (P = 0.009). The risk of contamination was increased by 2.9-fold when disinfection was performed manually (odds ratio, 2.9 (95% CI, 1.3-6.3)). Before disinfection, bacterial contamination was observed on 98.8% of probes. Microbial analysis revealed 36 different species of bacteria, including skin and environmental bacteria as well as pathogenic bacteria such as Staphylococcus aureus, enterobacteriaceae and Pseudomonas spp. Considering the high number of contaminated probes and bacterial species found, disinfection of the ultrasound probe's body and handle should be performed after each use to decrease the risk of cross-contamination. This study favored automated disinfection owing to its significantly higher efficacy compared with a manual method. Copyright © 2015 ISUOG. Published by John Wiley & Sons Ltd. Copyright © 2015 ISUOG. Published by John Wiley & Sons Ltd.

  3. New fully automated software for assessment of brachial artery flow- mediated dilation with advantages of continuous measurement.

    PubMed

    Ercan, Ertuğrul; Kırılmaz, Bahadır; Kahraman, İsmail; Bayram, Vildan; Doğan, Hüseyin

    2012-11-01

    Flow-mediated dilation (FMD) is used to evaluate endothelial functions. Computer-assisted analysis utilizing edge detection permits continuous measurements along the vessel wall. We have developed a new fully automated software program to allow accurate and reproducible measurement. FMD has been measured and analyzed in 18 coronary artery disease (CAD) patients and 17 controls both by manually and by the software developed (computer supported) methods. The agreement between methods was assessed by Bland-Altman analysis. The mean age, body mass index and cardiovascular risk factors were higher in CAD group. Automated FMD% measurement for the control subjects was 18.3±8.5 and 6.8±6.5 for the CAD group (p=0.0001). The intraobserver and interobserver correlation for automated measurement was high (r=0.974, r=0.981, r=0.937, r=0.918, respectively). Manual FMD% at 60th second was correlated with automated FMD % (r=0.471, p=0.004). The new fully automated software© can be used to precise measurement of FMD with low intra- and interobserver variability than manual assessment.

  4. Reliability of chemotherapy preparation processes: Evaluating independent double-checking and computer-assisted gravimetric control.

    PubMed

    Carrez, Laurent; Bouchoud, Lucie; Fleury-Souverain, Sandrine; Combescure, Christophe; Falaschi, Ludivine; Sadeghipour, Farshid; Bonnabry, Pascal

    2017-03-01

    Background and objectives Centralized chemotherapy preparation units have established systematic strategies to avoid errors. Our work aimed to evaluate the accuracy of manual preparations associated with different control methods. Method A simulation study in an operational setting used phenylephrine and lidocaine as markers. Each operator prepared syringes that were controlled using a different method during each of three sessions (no control, visual double-checking, and gravimetric control). Eight reconstitutions and dilutions were prepared in each session, with variable doses and volumes, using different concentrations of stock solutions. Results were analyzed according to qualitative (choice of stock solution) and quantitative criteria (accurate, <5% deviation from the target concentration; weakly accurate, 5%-10%; inaccurate, 10%-30%; wrong, >30% deviation). Results Eleven operators carried out 19 sessions. No final preparation (n = 438) contained a wrong drug. The protocol involving no control failed to detect 1 of 3 dose errors made and double-checking failed to detect 3 of 7 dose errors. The gravimetric control method detected all 5 out of 5 dose errors. The accuracy of the doses measured was equivalent across the control methods ( p = 0.63 Kruskal-Wallis). The final preparations ranged from 58% to 60% accurate, 25% to 27% weakly accurate, 14% to 17% inaccurate and 0.9% wrong. A high variability was observed between operators. Discussion Gravimetric control was the only method able to detect all dose errors, but it did not improve dose accuracy. A dose accuracy with <5% deviation cannot always be guaranteed using manual production. Automation should be considered in the future.

  5. Proceedings of the Annual Conference on Manual Control (15th) held March 20 - 22, 1979, Wright State University, Dayton, Ohio

    DTIC Science & Technology

    1979-11-01

    Performance in a Precognitive Tracking Task," Proc. 13th Annual Conf. on Manual Control, pp. 152-165, June 1977. (32] Repa Brian S. and Robert S. Zucker...operators that have received attention in manual control. Precognitive manual control displays differ from the pursuit and compensatory displays of the

  6. Manual traffic control for planned special events and emergencies.

    DOT National Transportation Integrated Search

    2015-11-01

    Manual traffic control is a common intersection control strategy in which trained personnel, : typically police law enforcement officers, allocate intersection right-of-way to approaching vehicles. : Manual intersection control is a key part of manag...

  7. The effect of manual therapy and exercise in patients with chronic low back pain: Double blind randomized controlled trial.

    PubMed

    Ulger, Ozlem; Demirel, Aynur; Oz, Müzeyyen; Tamer, Seval

    2017-11-06

    To determine the effects of spinal stabilization exercises (SSE) and manual therapy methods on pain, function and quality of life (QoL) levels in individuals with chronic low back pain (CLBP). A total of one-hundred thirteen patients diagnosed as CLBP were enrolled to the study. The patients allocated into Spinal Stabilization group (SG) and manual therapy group (MG), randomly. While SSE performed in SG, soft tissue mobilizations, muscle-energy techniques, joint mobilizations and manipulations were performed in MG. While the severity of pain was assessed with Visual Analog Scale (VAS), Oswestry Disability Index (ODI) and Short Form 36 (SF-36) assessments were performed to evaluate the functional status and QoL, respectively. All assessments were repeated before and after the treatment. Intragroup analyses both treatments were effective in terms of sub parameters of pain, function and life quality (p< 0.05). Inter group analyses, there was more reduction in pain and improvement in functional status in favor of MG (p< 0.05). This study showed that SSE and manual therapy methods have the same effects on QoL, while the manual treatment is more effective on the pain and functional parameters in particular.

  8. The integrated manual and automatic control of complex flight systems

    NASA Technical Reports Server (NTRS)

    Schmidt, D. K.

    1983-01-01

    Development of a unified control synthesis methodology for complex and/or non-conventional flight vehicles, and prediction techniques for the handling characteristics of such vehicles are reported. Identification of pilot dynamics and objectives, using time domain and frequency domain methods is proposed.

  9. Sensor fault-tolerant control for gear-shifting engaging process of automated manual transmission

    NASA Astrophysics Data System (ADS)

    Li, Liang; He, Kai; Wang, Xiangyu; Liu, Yahui

    2018-01-01

    Angular displacement sensor on the actuator of automated manual transmission (AMT) is sensitive to fault, and the sensor fault will disturb its normal control, which affects the entire gear-shifting process of AMT and results in awful riding comfort. In order to solve this problem, this paper proposes a method of fault-tolerant control for AMT gear-shifting engaging process. By using the measured current of actuator motor and angular displacement of actuator, the gear-shifting engaging load torque table is built and updated before the occurrence of the sensor fault. Meanwhile, residual between estimated and measured angular displacements is used to detect the sensor fault. Once the residual exceeds a determined fault threshold, the sensor fault is detected. Then, switch control is triggered, and the current observer and load torque table estimates an actual gear-shifting position to replace the measured one to continue controlling the gear-shifting process. Numerical and experiment tests are carried out to evaluate the reliability and feasibility of proposed methods, and the results show that the performance of estimation and control is satisfactory.

  10. Novel non-contact control system of electric bed for medical healthcare.

    PubMed

    Lo, Chi-Chun; Tsai, Shang-Ho; Lin, Bor-Shyh

    2017-03-01

    A novel non-contact controller of the electric bed for medical healthcare was proposed in this study. Nowadays, the electric beds are widely used for hospitals and home-care, and the conventional control method of the electric beds usually involves in the manual operation. However, it is more difficult for the disabled and bedridden patients, who might totally depend on others, to operate the conventional electric beds by themselves. Different from the current controlling method, the proposed system provides a new concept of controlling the electric bed via visual stimuli, without manual operation. The disabled patients could operate the electric bed by focusing on the control icons of a visual stimulus tablet in the proposed system. Besides, a wearable and wireless EEG acquisition module was also implemented to monitor the EEG signals of patients. The experimental results showed that the proposed system successfully measured and extracted the EEG features related to visual stimuli, and the disabled patients could operate the adjustable function of the electric bed by themselves to effectively reduce the long-term care burden.

  11. Reproducible segmentation of white matter hyperintensities using a new statistical definition.

    PubMed

    Damangir, Soheil; Westman, Eric; Simmons, Andrew; Vrenken, Hugo; Wahlund, Lars-Olof; Spulber, Gabriela

    2017-06-01

    We present a method based on a proposed statistical definition of white matter hyperintensities (WMH), which can work with any combination of conventional magnetic resonance (MR) sequences without depending on manually delineated samples. T1-weighted, T2-weighted, FLAIR, and PD sequences acquired at 1.5 Tesla from 119 subjects from the Kings Health Partners-Dementia Case Register (healthy controls, mild cognitive impairment, Alzheimer's disease) were used. The segmentation was performed using a proposed definition for WMH based on the one-tailed Kolmogorov-Smirnov test. The presented method was verified, given all possible combinations of input sequences, against manual segmentations and a high similarity (Dice 0.85-0.91) was observed. Comparing segmentations with different input sequences to one another also yielded a high similarity (Dice 0.83-0.94) that exceeded intra-rater similarity (Dice 0.75-0.91). We compared the results with those of other available methods and showed that the segmentation based on the proposed definition has better accuracy and reproducibility in the test dataset used. Overall, the presented definition is shown to produce accurate results with higher reproducibility than manual delineation. This approach can be an alternative to other manual or automatic methods not only because of its accuracy, but also due to its good reproducibility.

  12. WIPP waste characterization program sampling and analysis guidance manual

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Not Available

    1991-01-01

    The Waste Isolation Pilot Plant (WIPP) Waste Characterization Program Sampling and Analysis Guidance Manual (Guidance Manual) provides a unified source of information on the sampling and analytical techniques that enable Department of Energy (DOE) facilities to comply with the requirements established in the current revision of the Quality Assurance Program Plan (QAPP) for the WIPP Experimental-Waste Characterization Program (the Program). This Guidance Manual includes all of the sampling and testing methodologies accepted by the WIPP Project Office (DOE/WPO) for use in implementing the Program requirements specified in the QAPP. This includes methods for characterizing representative samples of transuranic (TRU) wastesmore » at DOE generator sites with respect to the gas generation controlling variables defined in the WIPP bin-scale and alcove test plans, as well as waste container headspace gas sampling and analytical procedures to support waste characterization requirements under the WIPP test program and the Resource Conservation and Recovery Act (RCRA). The procedures in this Guidance Manual are comprehensive and detailed and are designed to provide the necessary guidance for the preparation of site specific procedures. The use of these procedures is intended to provide the necessary sensitivity, specificity, precision, and comparability of analyses and test results. The solutions to achieving specific program objectives will depend upon facility constraints, compliance with DOE Orders and DOE facilities' operating contractor requirements, and the knowledge and experience of the TRU waste handlers and analysts. With some analytical methods, such as gas chromatography/mass spectrometry, the Guidance Manual procedures may be used directly. With other methods, such as nondestructive/destructive characterization, the Guidance Manual provides guidance rather than a step-by-step procedure.« less

  13. A randomised controlled trial to explore attitudes to routine scale and polish and compare manual versus ultrasonic scaling in the general dental service in Scotland [ISRCTN99609795

    PubMed Central

    Bonner, Brian C; Young, Linda; Smith, Patricia A; McCombes, Wendy; Clarkson, Jan E

    2005-01-01

    Background To investigate, within general dental practice, patients' and vocational dental practitioners' (VDP) attitudes towards the benefits and costs of a simple scale and polish and to compare the experience of using manual versus ultrasonic instruments to scale teeth. Methods 28 VDPs and 420 patients participated. Patients were randomly allocated to either group. Patients' and VDPs' attitudes towards, and experience of, the scale and polish were elicited by means of self-administered questionnaires. Results The majority of patients (99%) believed a scale and polish was beneficial. VDPs considered ultrasonic treatment to be appropriate on significantly more occasions than they did for manual scale and polish (P < 0.001). Patient discomfort: with ultrasonic scaling 69.2% felt 'a little uncomfortable' or worse compared with 60% of those undergoing manual treatment (P = 0.072). VDPs considered treatment charges were appropriate for 77% of patients. Conclusion Routine scaling and polishing is considered beneficial by both patients and vocational trainees. The majority of patients, regardless of treatment method, experience some degree of discomfort when undergoing a scale and polish. VDPs showed a preference for the ultrasonic treatment method. PMID:15975140

  14. Electromagnetic navigated condylar positioning after high oblique sagittal split osteotomy of the mandible: a guided method to attain pristine temporomandibular joint conditions.

    PubMed

    Berger, Moritz; Nova, Igor; Kallus, Sebastian; Ristow, Oliver; Eisenmann, Urs; Dickhaus, Hartmut; Engel, Michael; Freudlsperger, Christian; Hoffmann, Jürgen; Seeberger, Robin

    2018-05-01

    Reproduction of the exact preoperative proximal-mandible position after osteotomy in orthognathic surgery is difficult to achieve. This clinical pilot study evaluated an electromagnetic (EM) navigation system for condylar positioning after high-oblique sagittal split osteotomy (HSSO). After HSSO as part of 2-jaw surgery, the position of 10 condyles was intraoperatively guided by an EM navigation system. As controls, 10 proximal segments were positioned by standard manual replacement. Accuracy was measured by pre- and postoperative cone beam computed tomography imaging. Overall, EM condyle repositioning was equally accurate compared with manual repositioning (P > .05). Subdivided into 3 axes, significant differences could be identified (P < .05). Nevertheless, no significantly and clinically relevant dislocations of the proximal segment of either the EM or the manual repositioning method could be shown (P > .05). This pilot study introduces a guided method for proximal segment positioning after HSSO by applying the intraoperative EM system. The data demonstrate the high accuracy of EM navigation, although manual replacement of the condyles could not be surpassed. However, EM navigation can avoid clinically hidden, severe malpositioning of the condyles. Copyright © 2017 Elsevier Inc. All rights reserved.

  15. H. W. Laboratory manual: 100 Area section

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Not Available

    1950-07-01

    The purpose of this manual is to present a Hazard Breakdown of all jobs normally encountered in the laboratory work of the three sections comprising the Analytic Section, Metallurgy and Control Division of the Technical Department. A Hazard Breakdown is a careful analysis of any job in which the source of possible dangers is clearly indicated for each particular step. The analysis is prepared by individuals who are thoroughly familiar with the specific job or procedure. It is felt that if the hazards herein outlined are recognized by the Laboratory personnel and the suggested safety cautions followed, the chance formore » injury will be minimized and the worker will become generally more safety conscious. The manual, which is prefaced by the general safety rules applying to all the laboratories, is divided into three main sections, one for each of the three sections into which the Laboratories Division is divided. These sections are as follows: Section 1 -- 200 Area Control; Section 2 -- 100 Area Control; Section 3 -- 300 Area Control, Essential Materials, and Methods Improvement.« less

  16. Inverse simulation system for manual-controlled rendezvous and docking based on artificial neural network

    NASA Astrophysics Data System (ADS)

    Zhou, Wanmeng; Wang, Hua; Tang, Guojin; Guo, Shuai

    2016-09-01

    The time-consuming experimental method for handling qualities assessment cannot meet the increasing fast design requirements for the manned space flight. As a tool for the aircraft handling qualities research, the model-predictive-control structured inverse simulation (MPC-IS) has potential applications in the aerospace field to guide the astronauts' operations and evaluate the handling qualities more effectively. Therefore, this paper establishes MPC-IS for the manual-controlled rendezvous and docking (RVD) and proposes a novel artificial neural network inverse simulation system (ANN-IS) to further decrease the computational cost. The novel system was obtained by replacing the inverse model of MPC-IS with the artificial neural network. The optimal neural network was trained by the genetic Levenberg-Marquardt algorithm, and finally determined by the Levenberg-Marquardt algorithm. In order to validate MPC-IS and ANN-IS, the manual-controlled RVD experiments on the simulator were carried out. The comparisons between simulation results and experimental data demonstrated the validity of two systems and the high computational efficiency of ANN-IS.

  17. Agreement between automated and manual quantification of corneal nerve fiber length: Implications for diabetic neuropathy research.

    PubMed

    Scarr, Daniel; Lovblom, Leif E; Ostrovski, Ilia; Kelly, Dylan; Wu, Tong; Farooqi, Mohammed A; Halpern, Elise M; Ngo, Mylan; Ng, Eduardo; Orszag, Andrej; Bril, Vera; Perkins, Bruce A

    2017-06-01

    Quantification of corneal nerve fiber length (CNFL) by in vivo corneal confocal microscopy represents a promising diabetic neuropathy biomarker, but applicability is limited by resource-intensive image analysis. We aimed to evaluate, in cross-sectional analysis of non-diabetic controls and patients with type 1 and type 2 diabetes with and without neuropathy, the agreement between manual and automated analysis protocols. Sixty-eight controls, 139 type 1 diabetes, and 249 type 2 diabetes participants underwent CNFL measurement (N=456). Neuropathy status was determined by clinical and electrophysiological criteria. CNFL was determined by manual (CNFL Manual , reference standard) and automated (CNFL Auto ) protocols, and results were compared for correlation and agreement using Spearman coefficients and the method of Bland and Altman (CNFL Manual subtracted from CNFL Auto ). Participants demonstrated broad variability in clinical characteristics associated with neuropathy. The mean age, diabetes duration, and HbA1c were 53±18years, 15.9±12.6years, and 7.4±1.7%, respectively, and 218 (56%) individuals with diabetes had neuropathy. Mean CNFL Manual was 15.1±4.9mm/mm 2 , and mean CNFL Auto was 10.5±3.7mm/mm 2 (CNFL Auto underestimation bias, -4.6±2.6mm/mm 2 corresponding to -29±17%). Percent bias was similar across non-diabetic controls (-33±12%), type 1 (-30±20%), and type 2 diabetes (-28±16%) subgroups (ANOVA, p=0.068), and similarly in diabetes participants with and without neuropathy. Levels of CNFL Auto and CNFL Manual were both inversely associated with neuropathy status. Although CNFL Auto substantially underestimated CNFL Manual , its bias was non-differential between diverse patient groups and its relationship with neuropathy status was preserved. Determination of diagnostic thresholds specific to CNFL Auto should be pursued in diagnostic studies of diabetic neuropathy. Copyright © 2016 Elsevier Inc. All rights reserved.

  18. Nutrient Control Design Manual

    EPA Science Inventory

    The purpose of this EPA design manual is to provide updated, state‐of‐the‐technology design guidance on nitrogen and phosphorus control at municipal Wastewater Treatment Plants (WWTPs). Similar to previous EPA manuals, this manual contains extensive information on the principles ...

  19. Forest Pest Control. Bulletin 759.

    ERIC Educational Resources Information Center

    Coleman, V. Rodney

    This manual describes the major forest types, the major species, seed orchards, and tree nurseries. Methods of identifying forest insect pests and diseases are given. The most common types of insecticides, fungicides, and herbicides are described. Both sprayer and granular applicator methods are discussed. Environmental considerations are…

  20. EPA Air Pollution Control Cost Manual

    EPA Science Inventory

    EPA's Air Pollution Control Cost Manual provides guidance for the development of accurate and consistent costs for air pollution control devices. A long-standing document prepared by EPA, the Control Cost Manual focuses on point source and stationary area source air pollution con...

  1. Motion Perception and Manual Control Performance During Passive Tilt and Translation Following Space Flight

    NASA Technical Reports Server (NTRS)

    Clement, Gilles; Wood, Scott J.

    2010-01-01

    This joint ESA-NASA study is examining changes in motion perception following Space Shuttle flights and the operational implications of post-flight tilt-translation ambiguity for manual control performance. Vibrotactile feedback of tilt orientation is also being evaluated as a countermeasure to improve performance during a closed-loop nulling task. METHODS. Data has been collected on 5 astronaut subjects during 3 preflight sessions and during the first 8 days after Shuttle landings. Variable radius centrifugation (216 deg/s) combined with body translation (12-22 cm, peak-to-peak) is utilized to elicit roll-tilt perception (equivalent to 20 deg, peak-to-peak). A forward-backward moving sled (24-390 cm, peak-to-peak) with or without chair tilting in pitch is utilized to elicit pitch tilt perception (equivalent to 20 deg, peak-to-peak). These combinations are elicited at 0.15, 0.3, and 0.6 Hz for evaluating the effect of motion frequency on tilt-translation ambiguity. In both devices, a closed-loop nulling task is also performed during pseudorandom motion with and without vibrotactile feedback of tilt. All tests are performed in complete darkness. PRELIMINARY RESULTS. Data collection is currently ongoing. Results to date suggest there is a trend for translation motion perception to be increased at the low and medium frequencies on landing day compared to pre-flight. Manual control performance is improved with vibrotactile feedback. DISCUSSION. The results of this study indicate that post-flight recovery of motion perception and manual control performance is complete within 8 days following short-duration space missions. Vibrotactile feedback of tilt improves manual control performance both before and after flight.

  2. Nutrient Control Design Manual

    EPA Science Inventory

    The Nutrient Control Design Manual will present an extensive state-of-the-technology review of the engineering design and operation of nitrogen and phosphorous control technologies and techniques applied at municipal wastewater treatment plants (WWTPs). This manual will present ...

  3. Ottawa panel evidence-based clinical practice guidelines for therapeutic exercises and manual therapy in the management of osteoarthritis.

    PubMed

    2005-09-01

    Osteoarthritis (OA) affects a large and growing proportion of the population. The purpose of this project was to create guidelines for the use of therapeutic exercises and manual therapy in the management of adult patients (>18 years of age) with a diagnosis of OA. All stages of the disease were included in the analysis, and studies of patients who had recent surgery or other rheumatologic, musculoskeletal, or spinal problems or of subjects without known pathology or impairments were excluded. The Ottawa Methods Group used Cochrane Collaboration methods to find and synthesize evidence from comparative controlled trials and then asked stakeholder groups to nominate representatives to serve on a panel of experts. The Ottawa Panel agreed on criteria for grading the strength of the recommendations and their supporting evidence. Of the 609 potential articles on therapeutic exercises for OA that were identified, 113 were considered potentially relevant, and 26 randomized controlled trials and controlled clinical trials were ultimately used. Sixteen positive recommendations of clinical benefit were developed for therapeutic exercises, especially strengthening exercises and general physical activity, particularly for the management of pain and improvement of functional status. Manual therapy combined with exercises also is recommended in the management of patients with OA. The Ottawa Panel recommends the use of therapeutic exercises alone, or combined with manual therapy, for managing patients with OA. There were a total of 16 positive recommendations: 13 grade A and 3 grade C+. The Ottawa Panel recommends the use of therapeutic exercises because of the strong evidence (grades A, B, and C+) in the literature.

  4. An evolutionary view of chromatography data systems used in bioanalysis.

    PubMed

    McDowall, R D

    2010-02-01

    This is a personal view of how chromatographic peak measurement and analyte quantification for bioanalysis have evolved from the manual methods of 1970 to the electronic working possible in 2010. In four decades there have been major changes from a simple chart recorder output (that was interpreted and quantified manually) through simple automation of peak measurement, calculation of standard curves and quality control values and instrument control to the networked chromatography data systems of today that are capable of interfacing with Laboratory Information Management Systems and other IT applications. The incorporation of electronic signatures to meet regulatory requirements offers a great opportunity for business improvement and electronic working.

  5. Radiological control manual. Revision 1

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Kloepping, R.

    1996-05-01

    This Lawrence Berkeley National Laboratory Radiological Control Manual (LBNL RCM) has been prepared to provide guidance for site-specific additions, supplements and interpretation of the DOE Radiological Control Manual. The guidance provided in this manual is one methodology to implement the requirements given in Title 10 Code of Federal Regulations Part 835 (10 CFR 835) and the DOE Radiological Control Manual. Information given in this manual is also intended to provide demonstration of compliance to specific requirements in 10 CFR 835. The LBNL RCM (Publication 3113) and LBNL Health and Safety Manual Publication-3000 form the technical basis for the LBNL RPPmore » and will be revised as necessary to ensure that current requirements from Rules and Orders are represented. The LBNL RCM will form the standard for excellence in the implementation of the LBNL RPP.« less

  6. Water Quality Control for Shrimp Pond Using Adaptive Neuro Fuzzy Inference System : The First Project

    NASA Astrophysics Data System (ADS)

    Umam, F.; Budiarto, H.

    2018-01-01

    Shrimp farming becomes the main commodity of society in Madura Island East Java Indonesia. Because of Madura island has a very extreme weather, farmers have difficulty in keeping the balance of pond water. As a consequence of this condition, there are some farmers experienced losses. In this study an adaptive control system was developed using ANFIS method to control pH balance (7.5-8.5), Temperature (25-31°C), water level (70-120 cm) and Dissolved Oxygen (4-7,5 ppm). Each parameter (pH, temperature, level and DO) is controlled separately but can work together. The output of the control system is in the form of pump activation which provides the antidote to the imbalance that occurs in pond water. The system is built with two modes at once, which are automatic mode and manual mode. The manual control interface based on android which is easy to use.

  7. Regulatory Pest Control. Pesticide Bulletin 1.

    ERIC Educational Resources Information Center

    Thornton, George C.

    This manual gives descriptions of and control methods for the imported fire ant, sweet potato pests, the white fringed beetle, the Japanese beetle, and phony peach disease. Toxicity, formulation, and application information is given for 2,4-D, methyl bromide, Chlordane, Mirex, and Mocap. Finally, environmental considerations and precautions are…

  8. Manual tracing versus smartphone application (app) tracing: a comparative study.

    PubMed

    Sayar, Gülşilay; Kilinc, Delal Dara

    2017-11-01

    This study aimed to compare the results of conventional manual cephalometric tracing with those acquired with smartphone application cephalometric tracing. The cephalometric radiographs of 55 patients (25 females and 30 males) were traced via the manual and app methods and were subsequently examined with Steiner's analysis. Five skeletal measurements, five dental measurements and two soft tissue measurements were managed based on 21 landmarks. The durations of the performances of the two methods were also compared. SNA (Sella, Nasion, A point angle) and SNB (Sella, Nasion, B point angle) values for the manual method were statistically lower (p < .001) than those for the app method. The ANB value for the manual method was statistically lower than that of app method. L1-NB (°) and upper lip protrusion values for the manual method were statistically higher than those for the app method. Go-GN/SN, U1-NA (°) and U1-NA (mm) values for manual method were statistically lower than those for the app method. No differences between the two methods were found in the L1-NB (mm), occlusal plane to SN, interincisal angle or lower lip protrusion values. Although statistically significant differences were found between the two methods, the cephalometric tracing proceeded faster with the app method than with the manual method.

  9. Enhanced insulin sensitivity and acute regulation of metabolic genes and signaling pathways after a single electrical or manual acupuncture session in female insulin-resistant rats.

    PubMed

    Benrick, Anna; Maliqueo, Manuel; Johansson, Julia; Sun, Miao; Wu, Xiaoke; Mannerås-Holm, Louise; Stener-Victorin, Elisabet

    2014-12-01

    To compare the effect of a single session of acupuncture with either low-frequency electrical or manual stimulation on insulin sensitivity and molecular pathways in the insulin-resistant dihydrotestosterone-induced rat polycystic ovary syndrome (PCOS) model. Both stimulations cause activation of afferent nerve fibers. In addition, electrical stimulation causes muscle contractions, enabling us to differentiate changes induced by activation of sensory afferents from contraction-induced changes. Control and PCOS rats were divided into no-stimulation, manual-, and electrical stimulation groups and insulin sensitivity was measured by euglycemic hyperinsulinemic clamp. Manually stimulated needles were rotated 180° ten times every 5 min, or low-frequency electrical stimulation was applied to evoke muscle twitches for 45 min. Gene and protein expression were analyzed by real-time PCR and Western blot. The glucose infusion rate (GIR) was lower in PCOS rats than in controls. Electrical stimulation was superior to manual stimulation during treatment but both methods increased GIR to the same extent in the post-stimulation period. Electrical stimulation decreased mRNA expression of Adipor2, Adrb1, Fndc5, Erk2, and Tfam in soleus muscle and increased ovarian Adrb2 and Pdf. Manual stimulation decreased ovarian mRNA expression of Erk2 and Sdnd. Electrical stimulation increased phosphorylated ERK levels in soleus muscle. One acupuncture session with electrical stimulation improves insulin sensitivity and modulates skeletal muscle gene and protein expression more than manual stimulation. Although electrical stimulation is superior to manual in enhancing insulin sensitivity during stimulation, they are equally effective after stimulation indicating that it is activation of sensory afferents rather than muscle contraction per se leading to the observed changes.

  10. Automated T2 relaxometry of the hippocampus for temporal lobe epilepsy.

    PubMed

    Winston, Gavin P; Vos, Sjoerd B; Burdett, Jane L; Cardoso, M Jorge; Ourselin, Sebastien; Duncan, John S

    2017-09-01

    Hippocampal sclerosis (HS), the most common cause of refractory temporal lobe epilepsy, is associated with hippocampal volume loss and increased T2 signal. These can be identified on quantitative imaging with hippocampal volumetry and T2 relaxometry. Although hippocampal segmentation for volumetry has been automated, T2 relaxometry currently involves subjective and time-consuming manual delineation of regions of interest. In this work, we develop and validate an automated technique for hippocampal T2 relaxometry. Fifty patients with unilateral or bilateral HS and 50 healthy controls underwent T 1 -weighted and dual-echo fast recovery fast spin echo scans. Hippocampi were automatically segmented using a multi-atlas-based segmentation algorithm (STEPS) and a template database. Voxelwise T2 maps were determined using a monoexponential fit. The hippocampal segmentations were registered to the T2 maps and eroded to reduce partial volume effect. Voxels with T2 >170 msec excluded to minimize cerebrospinal fluid (CSF) contamination. Manual determination of T2 values was performed twice in each subject. Twenty controls underwent repeat scans to assess interscan reproducibility. Hippocampal T2 values were reliably determined using the automated method. There was a significant ipsilateral increase in T2 values in HS (p < 0.001), and a smaller but significant contralateral increase. The combination of hippocampal volumes and T2 values separated the groups well. There was a strong correlation between automated and manual methods for hippocampal T2 measurement (0.917 left, 0.896 right, both p < 0.001). Interscan reproducibility was superior for automated compared to manual measurements. Automated hippocampal segmentation can be reliably extended to the determination of hippocampal T2 values, and a combination of hippocampal volumes and T2 values can separate subjects with HS from healthy controls. There is good agreement with manual measurements, and the technique is more reproducible on repeat scans than manual measurement. This protocol can be readily introduced into a clinical workflow for the assessment of patients with focal epilepsy. © 2017 The Authors. Epilepsia published by Wiley Periodicals, Inc. on behalf of International League Against Epilepsy.

  11. [Automatic adjustment control system for DC glow discharge plasma source].

    PubMed

    Wan, Zhen-zhen; Wang, Yong-qing; Li, Xiao-jia; Wang, Hai-zhou; Shi, Ning

    2011-03-01

    There are three important parameters in the DC glow discharge process, the discharge current, discharge voltage and argon pressure in discharge source. These parameters influence each other during glow discharge process. This paper presents an automatic control system for DC glow discharge plasma source. This system collects and controls discharge voltage automatically by adjusting discharge source pressure while the discharge current is constant in the glow discharge process. The design concept, circuit principle and control program of this automatic control system are described. The accuracy is improved by this automatic control system with the method of reducing the complex operations and manual control errors. This system enhances the control accuracy of glow discharge voltage, and reduces the time to reach discharge voltage stability. The glow discharge voltage stability test results with automatic control system are provided as well, the accuracy with automatic control system is better than 1% FS which is improved from 4% FS by manual control. Time to reach discharge voltage stability has been shortened to within 30 s by automatic control from more than 90 s by manual control. Standard samples like middle-low alloy steel and tin bronze have been tested by this automatic control system. The concentration analysis precision has been significantly improved. The RSDs of all the test result are better than 3.5%. In middle-low alloy steel standard sample, the RSD range of concentration test result of Ti, Co and Mn elements is reduced from 3.0%-4.3% by manual control to 1.7%-2.4% by automatic control, and that for S and Mo is also reduced from 5.2%-5.9% to 3.3%-3.5%. In tin bronze standard sample, the RSD range of Sn, Zn and Al elements is reduced from 2.6%-4.4% to 1.0%-2.4%, and that for Si, Ni and Fe is reduced from 6.6%-13.9% to 2.6%-3.5%. The test data is also shown in this paper.

  12. Hepatoprotective effect of manual acupuncture at acupoint GB34 against CCl4-induced chronic liver damage in rats

    PubMed Central

    Yim, Yun-Kyoung; Lee, Hyun; Hong, Kwon-Eui; Kim, Young-Il; Lee, Byung-Ryul; Kim, Tae-Han; Yi, Ji-Young

    2006-01-01

    AIM: To investigate the hepatoprotective effect of manual acupuncture at Yanglingquan (GB34) on CCl4-induced chronic liver damage in rats. METHODS: Rats were injected intraperitoneally with CCl4 (1 mL/kg) and treated with manual acupuncture using reinforcing manipulation techniques at left GB34 (Yanglingquan) 3 times a week for 10 wk. A non-acupoint in left gluteal area was selected as a sham point. To estimate the hepatoprotective effect of manual acupuncture at GB34, measurement of liver index, biochemical assays including serum ALT, AST, ALP and total cholesterol, histological analysis and blood cell counts were conducted. RESULTS: Manual acupuncture at GB34 reduced the liver index, serum ALT, AST, ALP and total cholesterol levels as compared with the control group and the sham acupuncture group. It also increased and normalized the populations of WBC and lymphocytes. CONCLUSION: Manual acupuncture with reinforcing manipulation techniques at left GB34 reduces liver toxicity, protects liver function and liver tissue, and normalizes immune activity in CCl4-intoxicated rats. PMID:16610030

  13. Agricultural Electricity. Electric Controls. Student Manual. Report No. 820/20.

    ERIC Educational Resources Information Center

    Benson, Robert T.

    Addressed to the student, this manual presents terms, abbreviations, and symbols used in discussing manual or automatic control of the flow of electric current. Diagrams accompany discussion of the following types of control devices and principles of operation: Heat sensitive controls (thermostats, thermal relays), light sensitive controls…

  14. Development of the Coordination between Posture and Manual Control

    ERIC Educational Resources Information Center

    Haddad, Jeffrey M.; Claxton, Laura J.; Keen, Rachel; Berthier, Neil E.; Riccio, Gary E.; Hamill, Joseph; Van Emmerik, Richard E. A.

    2012-01-01

    Studies have suggested that proper postural control is essential for the development of reaching. However, little research has examined the development of the coordination between posture and manual control throughout childhood. We investigated the coordination between posture and manual control in children (7- and 10-year-olds) and adults during…

  15. A Fully Automated Method for Quantifying and Localizing White Matter Hyperintensities on MR Images

    PubMed Central

    Wu, Minjie; Rosano, Caterina; Butters, Meryl; Whyte, Ellen; Nable, Megan; Crooks, Ryan; Meltzer, Carolyn C.; Reynolds, Charles F.; Aizenstein3, Howard J.

    2006-01-01

    White matter hyperintensities (WMH), commonly found on T2-weighted FLAIR brain MR images in the elderly, are associated with a number of neuropsychiatric disorders, including vascular dementia, Alzheimer’s disease, and late-life depression. Previous MRI studies of WMHs have primarily relied on the subjective and global (i.e., full-brain) ratings of WMH grade. In the current study we implement and validate an automated method for quantifying and localizing WMHs. We adapt a fuzzy connected algorithm to automate the segmentation of WMHs and use a demons-based image registration to automate the anatomic localization of the WMHs using the Johns Hopkins University White Matter Atlas. The method is validated using the brain MR images acquired from eleven elderly subjects with late-onset late-life depression (LLD) and eight elderly controls. This dataset was chosen because LLD subjects are known to have significant WMH burden. The volumes of WMH identified in our automated method are compared with the accepted gold standard (manual ratings). A significant correlation of the automated method and the manual ratings is found (P<0.0001), thus demonstrating similar WMH quantifications of both methods. As has been shown in other studies e.g. (Taylor, et al. 2003)), we found there was a significantly greater WMH burden in the LLD subjects versus the controls for both the manual and automated method. The effect size was greater for the automated method, suggesting that it is a more specific measure. Additionally, we describe the anatomic localization of the WMHs in LLD subjects as well as in the control subjects, and detect the regions of interest (ROIs) specific for the WMH burden of LLD patients. Given the emergence of large neuroimage databases, techniques, such as that described here, will allow for a better understanding of the relationship between WMHs and neuropsychiatric disorders. PMID:17097277

  16. 46 CFR 160.133-9 - Preapproval review.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... manual as described in §§ 160.133-19 and 160.133-21 of this subpart; (7) A description of the quality... suppliers; (ii) The method for controlling the inventory of materials; (iii) The method for checking quality of fabrication and joints, including welding inspection procedures; and (iv) The inspection...

  17. 46 CFR 160.133-9 - Preapproval review.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... manual as described in §§ 160.133-19 and 160.133-21 of this subpart; (7) A description of the quality... suppliers; (ii) The method for controlling the inventory of materials; (iii) The method for checking quality of fabrication and joints, including welding inspection procedures; and (iv) The inspection...

  18. 46 CFR 160.170-9 - Preapproval review.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... manual as described in §§ 160.170-19 and 160.170-21 of this subpart; (7) A description of the quality... suppliers; (ii) The method for controlling the inventory of materials; (iii) The method for checking quality of fabrication and joints, including welding inspection procedures; and (iv) The inspection...

  19. 46 CFR 160.170-9 - Preapproval review.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... manual as described in §§ 160.170-19 and 160.170-21 of this subpart; (7) A description of the quality... suppliers; (ii) The method for controlling the inventory of materials; (iii) The method for checking quality of fabrication and joints, including welding inspection procedures; and (iv) The inspection...

  20. 46 CFR 160.133-9 - Preapproval review.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... manual as described in §§ 160.133-19 and 160.133-21 of this subpart; (7) A description of the quality... suppliers; (ii) The method for controlling the inventory of materials; (iii) The method for checking quality of fabrication and joints, including welding inspection procedures; and (iv) The inspection...

  1. 46 CFR 160.170-9 - Preapproval review.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... manual as described in §§ 160.170-19 and 160.170-21 of this subpart; (7) A description of the quality... suppliers; (ii) The method for controlling the inventory of materials; (iii) The method for checking quality of fabrication and joints, including welding inspection procedures; and (iv) The inspection...

  2. Radiometer Calibration and Characterization (RCC) User's Manual: Windows Version 4.0

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Andreas, Afshin M.; Wilcox, Stephen M.

    2016-02-29

    The Radiometer Calibration and Characterization (RCC) software is a data acquisition and data archival system for performing Broadband Outdoor Radiometer Calibrations (BORCAL). RCC provides a unique method of calibrating broadband atmospheric longwave and solar shortwave radiometers using techniques that reduce measurement uncertainty and better characterize a radiometer's response profile. The RCC software automatically monitors and controls many of the components that contribute to uncertainty in an instrument's responsivity. This is a user's manual and guide to the RCC software.

  3. [Evaluation of postoperative pain comparing manual and ultrasonic endodontic instrumentation in patients with cleft lip and palate].

    PubMed

    Brosco, H B; Pimentel, P A; Lacerda, A G; Nishiyama, C K; de Moraes, I G

    1989-01-01

    Our purpose was to compare incidence of post-surgical pain associated to the endodontic therapy where the instrumentation on the root canal was performed by the method of Marshall & Pappin and the method of Marshall & Pappin complemented by the ultrasonic. Seventy patients with only one tooth needing endodontic treatment were treated by one of the methods and, posteriorly, evaluated. The endodontic treatment was performed at one time and from the seventy teeth, thirty have been instrumented by the manual method complemented by the ultrasonic and forty by the manual instrumentation. The patients were clinically controlled after the endodontic treatment was finished during periods of 24, 48 and 72 hours to evaluate their post-surgical condition. The results suggest that were no statistically significant differences (p less than 0.05) in the incidence of pain between the employed methods or according to the pulpar semiologic condition in any of the observed periods. However, we have realized that there was a tendency for a smaller percentage of a postoperative pain in those cases of necropulpectamy treated by the endosonic ultrasonic synergistic system. In those cases of biopulpectomy this has been not observed.

  4. Comparative evaluation of root surface after manual instrumentation with and without Er:YAG laser as an auxiliary therapy: in-vitro study

    NASA Astrophysics Data System (ADS)

    Lizarelli, Rosane F. Z.; Ferreira, Zulene A.; Torquato, Tatiana M.; Sampaio, Jose E. C.; Bagnato, Vanderlei S.

    2000-03-01

    One of the most important difficulty in the periodontal disease treatment resides in the impossibility of decontamination of roots just affected by the periodontal disease through mechanical tools. Manual dental scaling results in the amorphous material without continuity solution due to the dental cut, denominated smear layer. The main purpose of the present study was to evaluate the structure of the radicular surface using two methods for periodontal treatments: manual and mechanical associated to the irrigation with water and with EDTA (ethylene diamine tetracycline acid), followed by the application of the Er:YAG laser or the same without laser. Thirty teeth were selected with periodontal involvement. The radicular surface was scraped with ultrasound and planed vigorously, with manual instrumentation. The teeth were divided ramdomically in several groups: GI -- control, just manual instrumentation and water irrigation; GII -- manual instrumentation, EDTA irrigation; GIII -- manual instrumentation, EDTA irrigation, Er:YAG laser irradiation; GIV -- manual instrumentation, laser irradiation; and, GV -- manual instrumentation, laser irradiation and EDTA. Kruskall Wallis statistical test was applied and shows that there was not significance difference at the level of 5% among the five groups, however, when the groups were compared in pairs, GII X GIV and GII X GV shows difference in 5%, and GI X GII, difference at 1% level. The results show equivalence around the used methodology.

  5. Treatment manuals and the advancement of psychoanalytic knowledge: The Treatment Manual of the Tavistock Adult Depression Study.

    PubMed

    Taylor, David

    2015-06-01

    This paper has two aims: first, it seeks to understand the absence of treatment manuals in psychoanalysis. Secondly, it summarizes the treatment manual of the Tavistock Adult Depression Study, which describes the form of psychoanalytic psychotherapy whose effectiveness has been evaluated both in the Tavistock Adult Depression Study (TADS); and in the German Die Langzeittherapie bei chronischen Depressionen (LAC) Studie. Throughout the history of psychoanalysis, opinions about treatment manuals, empirical research and their antecedents have been deeply divided. After tracing the often polarized unfolding of these matters, the paper proposes that emotional and cognitive difficulties as well as scientific ones underpin their persistence. It is suggested that greater familiarity with them may lead to better combinations of outcome research and psychoanalysis: for example, the Tavistock manual seeks to match one account of the objects, aims, values, spirit and methods of psychoanalysis (as well as of connected forms of psychoanalytic psychotherapy); and also to meet what is required of treatment manuals by random allocation controlled trials. It has been a crucial element in the above studies of the outcome of long-term psychoanalytic psychotherapies with chronically depressed patients. After describing the Tavistock Manual, the paper concludes suggesting that, if appropriately constructed, treatment manuals can make a contribution to the advancement of specifically psychoanalytic knowledge. Copyright © 2015 Institute of Psychoanalysis.

  6. Effective teaching of manual skills to physiotherapy students: a randomised clinical trial.

    PubMed

    Rossettini, Giacomo; Rondoni, Angie; Palese, Alvisa; Cecchetto, Simone; Vicentini, Marco; Bettale, Fernanda; Furri, Laura; Testa, Marco

    2017-08-01

    To date, despite the relevance of manual skills laboratories in physiotherapy education, evidence on the effectiveness of different teaching methods is limited. Peyton's four-step and the 'See one, do one' approaches were compared for their effectiveness in teaching manual skills. A cluster randomised controlled trial was performed among final-year, right-handed physiotherapy students, without prior experience in manual therapy or skills laboratories. The manual technique of C1-C2 passive right rotation was taught by different experienced physiotherapist using Peyton's four-step approach (intervention group) and the 'See one, do one' approach (control group). Participants, teachers and assessors were blinded to the aims of the study. Primary outcomes were quality of performance at the end of the skills laboratories, and after 1 week and 1 month. Secondary outcomes were time required to teach, time required to perform the procedure and student satisfaction. A total of 39 students were included in the study (21 in the intervention group and 18 in the control group). Their main characteristics were homogeneous at baseline. The intervention group showed better quality of performance in the short, medium and long terms (F 1,111  = 35.91, p < 0.001). Both groups demonstrated decreased quality of performance over time (F 2,111  = 12.91, p < 0.001). The intervention group reported significantly greater mean ± standard deviation satisfaction (4.31 ± 1.23) than the control group (4.03 ± 1.31) (p < 0.001). Although there was no significant difference between the two methods in the time required for teaching, the time required by the intervention group to perform the procedure was significantly lower immediately after the skills laboratories and over time (p < 0.001). Peyton's four-step approach is more effective than the 'See one, do one' approach in skills laboratories aimed at developing physiotherapy student competence in C1-C2 passive mobilisation. © 2017 John Wiley & Sons Ltd and The Association for the Study of Medical Education.

  7. Comparison of anaesthetic gas consumption and stability of anaesthesia using automatic and manual control over the course of anaesthesia.

    PubMed

    Skalec, Tomasz; Górecka-Dolny, Agnieszka; Zieliński, Stanisław; Gibek, Mirosław; Stróżecki, Łukasz; Kübler, Andrzej

    2017-01-01

    The automatic control module of end-tidal volatile agents (EtC) was designed to reduce the consumption of anaesthetic gases, increase the stability of general anaesthesia and reduce the need for adjustments in the settings of the anaesthesia machine. The aim of this study was to verify these hypotheses. The course of general anaesthesia with the use of the EtC module was analysed for haemodynamic stability, depth of anaesthesia, end-expiratory concentration of anaesthetic, number of ventilator key presses, fentanyl supply, consumption of volatile agents and anaesthesia and operation times. These data were compared with the data obtained during general anaesthesia controlled manually and were processed with statistical tests. Seventy-four patients underwent general anaesthesia for scheduled operations. Group AUTO-ET (n = 35) was anaesthetized with EtC, and group MANUAL-ET (n = 39) was controlled manually. Both populations presented similar anaesthesia stability. No differences were noted in the time of anaesthesia, saturation up to MAC 1.0 or awakening. Data revealed no differences in mean EtAA or the fentanyl dose. The AUTO-ET group exhibited fewer key presses per minute, 0.0603 min⁻¹, whereas the MANUAL-ET exhibited a value of 0.0842 min⁻¹; P = 0.001. The automatic group consumed more anaesthetic and oxygen per minute (sevoflurane 0.1171 mL min⁻¹; IQR: 0.0503; oxygen 1.8286 mL min⁻¹, IQR: 1,3751) than MANUAL-ET (sevoflurane 0.0824 mL min⁻¹, IQR: 0.0305; oxygen 1,288 mL min⁻¹, IQR: 0,6517) (P = 0.0028 and P = 0.0171, respectively). Both methods are equally stable and safe for patients. The consumption of volatile agents was significantly increased in the AUTO-ET group. EtC considerably reduces the number of key presses.

  8. Putaminal volume and diffusion in early familial Creutzfeldt-Jakob disease.

    PubMed

    Seror, Ilana; Lee, Hedok; Cohen, Oren S; Hoffmann, Chen; Prohovnik, Isak

    2010-01-15

    The putamen is centrally implicated in the pathophysiology of Creutzfeldt-Jakob Disease (CJD). To our knowledge, its volume has never been measured in this disease. We investigated whether gross putaminal atrophy can be detected by MRI in early stages, when the diffusion is already reduced. Twelve familial CJD patients with the E200K mutation and 22 healthy controls underwent structural and diffusion MRI scans. The putamen was identified in anatomical scans by two methods: manual tracing by a blinded investigator, and automatic parcellation by a computerized segmentation procedure (FSL FIRST). For each method, volume and mean Apparent Diffusion Coefficient (ADC) were calculated. ADC was significantly lower in CJD patients (697+/-64 microm(2)/s vs. 750+/-31 microm(2)/s, p<0.005), as expected, but the volume was not reduced. The computerized FIRST delineation yielded comparable ADC values to the manual method, but computerized volumes were smaller than manual tracing values. We conclude that significant diffusion reduction in the putamen can be detected by delineating the structure manually or with a computerized algorithm. Our findings confirm and extend previous voxel-based and observational studies. Putaminal volume was not reduced in our early-stage patients, thus confirming that diffusion abnormalities precede detectible atrophy in this structure.

  9. EEG Neurofeedback for ADHD: Double-Blind Sham-Controlled Randomized Pilot Feasibility Trial

    ERIC Educational Resources Information Center

    Arnold, L. Eugene; Lofthouse, Nicholas; Hersch, Sarah; Pan, Xueliang; Hurt, Elizabeth; Bates, Bethany; Kassouf, Kathleen; Moone, Stacey; Grantier, Cara

    2013-01-01

    Objective: Preparing for a definitive randomized clinical trial (RCT) of neurofeedback (NF) for ADHD, this pilot trial explored feasibility of a double-blind, sham-controlled design and adherence/palatability/relative effect of two versus three treatments/week. Method: Unmedicated 6- to 12-year-olds with "Diagnostic and Statistical Manual of…

  10. 78 FR 59712 - Notice of Availability of the Draft Environmental Impact Statement for the 3 Bars Ecosystem and...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-09-27

    ... treatment methods would include manual, mechanical, and biological control treatments, prescribed fire or wildland fire for resource benefit, and other management actions. In order to implement the proposed 3 Bars... enhancement, fire and fuels management, control of weeds, woodland and rangeland values, wetland and riparian...

  11. Ornamental and Turf Pest Control. Bulletin 764.

    ERIC Educational Resources Information Center

    Bowyer, Timothy H.; And Others

    This manual gives descriptions of and methods for control of diseases and insect pests of ornamental plants, weeds, and diseases and insect pests of turf plants. Included are diseases caused by fungi such as cankers, leaf galls, and rust; diseases caused by bacteria such as bacterial blight and crown gall; and diseases caused by nematodes and…

  12. Safe, Effective Use of Pesticides, A Manual for Commercial Applicators: Aquatic Pest Control.

    ERIC Educational Resources Information Center

    Extension Service (USDA), Washington, DC.

    This manual is intended to assist pesticide applicators in the area of aquatic pest control meet the requirements of the Michigan Department of Agriculture for certification. The Environmental Protection Agency (EPA) Aquatic Pest Control Guide served as a basis for this manual. The six sections presented describe: (1) Aquatic pest control; (2)…

  13. 77 FR 28455 - National Standards for Traffic Control Devices; the Manual on Uniform Traffic Control Devices for...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-05-14

    ... Options for design and applications of traffic control devices, this Manual should not be considered a... application of traffic control devices, as well as in the location and design of roads and streets that the..., while this Manual provides Standards, Guidance, and Options for design and applications of traffic...

  14. Architectural study of the design and operation of advanced force feedback manual controllers

    NASA Technical Reports Server (NTRS)

    Tesar, Delbert; Kim, Whee-Kuk

    1990-01-01

    A teleoperator system consists of a manual controller, control hardware/software, and a remote manipulator. It was employed in either hazardous or unstructured, and/or remote environments. In teleoperation, the main-in-the-loop is the central concept that brings human intelligence to the teleoperator system. When teleoperation involves contact with an uncertain environment, providing the feeling of telepresence to the human operator is one of desired characteristics of the teleoperator system. Unfortunately, most available manual controllers in bilateral or force-reflecting teleoperator systems can be characterized by their bulky size, high costs, or lack of smoothness and transparency, and elementary architectures. To investigate other alternatives, a force-reflecting, 3 degree of freedom (dof) spherical manual controller is designed, analyzed, and implemented as a test bed demonstration in this research effort. To achieve an improved level of design to meet criteria such as compactness, portability, and a somewhat enhanced force-reflecting capability, the demonstration manual controller employs high gear-ratio reducers. To reduce the effects of the inertia and friction on the system, various force control strategies are applied and their performance investigated. The spherical manual controller uses a parallel geometry to minimize inertial and gravitational effects on its primary task of transparent information transfer. As an alternative to the spherical 3-dof manual controller, a new conceptual (or parallel) spherical 3-dof module is introduced with a full kinematic analysis. Also, the resulting kinematic properties are compared to those of other typical spherical 3-dof systems. The conceptual design of a parallel 6-dof manual controller and its kinematic analysis is presented. This 6-dof manual controller is similar to the Stewart Platform with the actuators located on the base to minimize the dynamic effects. Finally, a combination of the new 3-dof and 6-dof concepts is presented as a feasible test-bed for enhanced performance in a 9-dof system.

  15. Development and validation of an automated ventilator-associated event electronic surveillance system: A report of a successful implementation.

    PubMed

    Hebert, Courtney; Flaherty, Jennifer; Smyer, Justin; Ding, Jing; Mangino, Julie E

    2018-03-01

    Surveillance is an important tool for infection control; however, this task can often be time-consuming and take away from infection prevention activities. With the increasing availability of comprehensive electronic health records, there is an opportunity to automate these surveillance activities. The objective of this article is to describe the implementation of an electronic algorithm for ventilator-associated events (VAEs) at a large academic medical center METHODS: This article reports on a 6-month manual validation of a dashboard for VAEs. We developed a computerized algorithm for automatically detecting VAEs and compared the output of this algorithm to the traditional, manual method of VAE surveillance. Manual surveillance by the infection preventionists identified 13 possible and 11 probable ventilator-associated pneumonias (VAPs), and the VAE dashboard identified 16 possible and 13 probable VAPs. The dashboard had 100% sensitivity and 100% accuracy when compared with manual surveillance for possible and probable VAP. We report on the successfully implemented VAE dashboard. Workflow of the infection preventionists was simplified after implementation of the dashboard with subjective time-savings reported. Implementing a computerized dashboard for VAE surveillance at a medical center with a comprehensive electronic health record is feasible; however, this required significant initial and ongoing work on the part of data analysts and infection preventionists. Copyright © 2018 Association for Professionals in Infection Control and Epidemiology, Inc. Published by Elsevier Inc. All rights reserved.

  16. Shared control on lunar spacecraft teleoperation rendezvous operations with large time delay

    NASA Astrophysics Data System (ADS)

    Ya-kun, Zhang; Hai-yang, Li; Rui-xue, Huang; Jiang-hui, Liu

    2017-08-01

    Teleoperation could be used in space on-orbit serving missions, such as object deorbits, spacecraft approaches, and automatic rendezvous and docking back-up systems. Teleoperation rendezvous and docking in lunar orbit may encounter bottlenecks for the inherent time delay in the communication link and the limited measurement accuracy of sensors. Moreover, human intervention is unsuitable in view of the partial communication coverage problem. To solve these problems, a shared control strategy for teleoperation rendezvous and docking is detailed. The control authority in lunar orbital maneuvers that involves two spacecraft as rendezvous and docking in the final phase was discussed in this paper. The predictive display model based on the relative dynamic equations is established to overcome the influence of the large time delay in communication link. We discuss and attempt to prove via consistent, ground-based simulations the relative merits of fully autonomous control mode (i.e., onboard computer-based), fully manual control (i.e., human-driven at the ground station) and shared control mode. The simulation experiments were conducted on the nine-degrees-of-freedom teleoperation rendezvous and docking simulation platform. Simulation results indicated that the shared control methods can overcome the influence of time delay effects. In addition, the docking success probability of shared control method was enhanced compared with automatic and manual modes.

  17. 46 CFR 62.25-10 - Manual alternate control systems.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 46 Shipping 2 2010-10-01 2010-10-01 false Manual alternate control systems. 62.25-10 Section 62.25-10 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) MARINE ENGINEERING VITAL SYSTEM AUTOMATION General Requirements for All Automated Vital Systems § 62.25-10 Manual alternate control systems...

  18. Massage, reflexology and other manual methods for pain management in labour.

    PubMed

    Smith, Caroline A; Levett, Kate M; Collins, Carmel T; Jones, Leanne

    2012-02-15

    Many women would like to avoid pharmacological or invasive methods of pain management in labour, and this may contribute towards the popularity of complementary methods of pain management. This review examined currently available evidence supporting the use of manual healing methods including massage and reflexology for pain management in labour. To examine the effects of manual healing methods including massage and reflexology for pain management in labour on maternal and perinatal morbidity. We searched the Cochrane Pregnancy and Childbirth Group's Trials Register (30 June 2011), the Cochrane Central Register of Controlled Trials (CENTRAL) (The Cochrane Library 2011, Issue 2 of 4), MEDLINE (1966 to 30 June 2011), CINAHL (1980 to 30 June 2011), the Australian and New Zealand Clinical Trial Registry (30 June 2011), Chinese Clinical Trial Register (30 June 2011), Current Controlled Trials (30 June 2011), ClinicalTrials.gov, (30 June 2011) ISRCTN Register (30 June 2011), National Centre for Complementary and Alternative Medicine (NCCAM) (30 June 2011) and the WHO International Clinical Trials Registry Platform (30 June 2011). Randomised controlled trials comparing manual healing methods with standard care, no treatment, other non-pharmacological forms of pain management in labour or placebo. Two authors independently assessed trial quality and extracted data. We attempted to contact study authors for additional information. We included six trials, with data reporting on five trials and 326 women in the meta-analysis. We found trials for massage only. Less pain during labour was reported from massage compared with usual care during the first stage of labour (standardised mean difference (SMD) -0.82, 95% confidence interval (CI) -1.17 to -0.47), four trials, 225 women), and labour pain was reduced in one trial of massage compared with music (risk ratio (RR) 0.40, 95% CI 0.18 to 0.89, 101 women). One trial of massage compared with usual care found reduced anxiety during the first stage of labour (MD -16.27, 95% CI -27.03 to -5.51, 60 women). No trial was assessed as being at a low risk of bias for all quality domains. Massage may have a role in reducing pain, and improving women's emotional experience of labour. However, there is a need for further research.

  19. Validity of a Manual Soft Tissue Profile Prediction Method Following Mandibular Setback Osteotomy

    PubMed Central

    Kolokitha, Olga-Elpis

    2007-01-01

    Objectives The aim of this study was to determine the validity of a manual cephalometric method used for predicting the post-operative soft tissue profiles of patients who underwent mandibular setback surgery and compare it to a computerized cephalometric prediction method (Dentofacial Planner). Lateral cephalograms of 18 adults with mandibular prognathism taken at the end of pre-surgical orthodontics and approximately one year after surgery were used. Methods To test the validity of the manual method the prediction tracings were compared to the actual post-operative tracings. The Dentofacial Planner software was used to develop the computerized post-surgical prediction tracings. Both manual and computerized prediction printouts were analyzed by using the cephalometric system PORDIOS. Statistical analysis was performed by means of t-test. Results Comparison between manual prediction tracings and the actual post-operative profile showed that the manual method results in more convex soft tissue profiles; the upper lip was found in a more prominent position, upper lip thickness was increased and, the mandible and lower lip were found in a less posterior position than that of the actual profiles. Comparison between computerized and manual prediction methods showed that in the manual method upper lip thickness was increased, the upper lip was found in a more anterior position and the lower anterior facial height was increased as compared to the computerized prediction method. Conclusions Cephalometric simulation of post-operative soft tissue profile following orthodontic-surgical management of mandibular prognathism imposes certain limitations related to the methods implied. However, both manual and computerized prediction methods remain a useful tool for patient communication. PMID:19212468

  20. Trust, control strategies and allocation of function in human-machine systems.

    PubMed

    Lee, J; Moray, N

    1992-10-01

    As automated controllers supplant human intervention in controlling complex systems, the operators' role often changes from that of an active controller to that of a supervisory controller. Acting as supervisors, operators can choose between automatic and manual control. Improperly allocating function between automatic and manual control can have negative consequences for the performance of a system. Previous research suggests that the decision to perform the job manually or automatically depends, in part, upon the trust the operators invest in the automatic controllers. This paper reports an experiment to characterize the changes in operators' trust during an interaction with a semi-automatic pasteurization plant, and investigates the relationship between changes in operators' control strategies and trust. A regression model identifies the causes of changes in trust, and a 'trust transfer function' is developed using time series analysis to describe the dynamics of trust. Based on a detailed analysis of operators' strategies in response to system faults we suggest a model for the choice between manual and automatic control, based on trust in automatic controllers and self-confidence in the ability to control the system manually.

  1. Contour detection improved by context-adaptive surround suppression.

    PubMed

    Sang, Qiang; Cai, Biao; Chen, Hao

    2017-01-01

    Recently, many image processing applications have taken advantage of a psychophysical and neurophysiological mechanism, called "surround suppression" to extract object contour from a natural scene. However, these traditional methods often adopt a single suppression model and a fixed input parameter called "inhibition level", which needs to be manually specified. To overcome these drawbacks, we propose a novel model, called "context-adaptive surround suppression", which can automatically control the effect of surround suppression according to image local contextual features measured by a surface estimator based on a local linear kernel. Moreover, a dynamic suppression method and its stopping mechanism are introduced to avoid manual intervention. The proposed algorithm is demonstrated and validated by a broad range of experimental results.

  2. Consensus statement: patient safety, healthcare-associated infections and hospital environmental surfaces.

    PubMed

    Roques, Christine; Al Mousa, Haifaa; Duse, Adriano; Gallagher, Rose; Koburger, Torsten; Lingaas, Egil; Petrosillo, Nicola; Škrlin, Jasenka

    2015-01-01

    Healthcare-associated infections have serious implications for both patients and hospitals. Environmental surface contamination is the key to transmission of nosocomial pathogens. Routine manual cleaning and disinfection eliminates visible soil and reduces environmental bioburden and risk of transmission, but may not address some surface contamination. Automated area decontamination technologies achieve more consistent and pervasive disinfection than manual methods, but it is challenging to demonstrate their efficacy within a randomized trial of the multiple interventions required to reduce healthcare-associated infection rates. Until data from multicenter observational studies are available, automated area decontamination technologies should be an adjunct to manual cleaning and disinfection within a total, multi-layered system and risk-based approach designed to control environmental pathogens and promote patient safety.

  3. Manual de Adiestramiento sobre Terapia de Rehidratacion Oral y Control de las Enfermedades Diarreicas (Oral Rehydration Therapy and the Control of Diarrheal Diseases). Training for Development. Peace Corps Information Collection & Exchange Training Manual No. T-53.

    ERIC Educational Resources Information Center

    Clark, Mari; And Others

    This Spanish-language manual was developed to train Peace Corps volunteers and other community health workers in Spanish-speaking countries in oral rehydration therapy (ORT) and the control of diarrheal diseases. Using a competency-based format, the manual contains three training modules (organized in seven sessions) that focus on interrelated…

  4. First step in managing bulimia nervosa: controlled trial of therapeutic manual.

    PubMed Central

    Treasure, J.; Schmidt, U.; Troop, N.; Tiller, J.; Todd, G.; Keilen, M.; Dodge, E.

    1994-01-01

    OBJECTIVE--To test the short term efficacy of a self directed treatment manual for bulimia nervosa. DESIGN--Randomised controlled trial of the manual against cognitive behavioural therapy and a waiting list. SETTING--Tertiary referral centre. SUBJECTS--81 consecutive referrals presenting with bulimia nervosa or atypical bulimia nervosa. MAIN OUTCOME MEASURES--Frequency of binge eating, vomiting, and other behaviours to control weight as well as abstinence from these behaviours. RESULTS--Cognitive behavioural treatment produced a significant reduction in the frequency of binge eating, vomiting, and other behaviours to control weight. The manual significantly reduced frequency of binge eating and weight control behaviours other than vomiting, and there was no change in the group on the waiting list. Full remission was achieved in five (24%) of the group assigned to cognitive behavioural treatment, nine (22%) of the group who used the manual, and two (11%) of the group on the waiting list. CONCLUSIONS--A self directed treatment manual may be a useful first intervention in the treatment of bulimia nervosa. PMID:8142791

  5. MANUAL: ALTERNATIVE METHODS FOR FLUID DELIVERY AND RECOVERY

    EPA Science Inventory

    Controlling subsurface fluids is among the highest priorities in rnanaging sites with in situ contamination. Some applications direct fluid movement continually inward towards the site, whereas others attempt to recover contaminants and, ultimately, close the site. Both these...

  6. Effectiveness of Plaque Control with Novel Pediatric Oral Hygiene Need Station (Modified Oral Irrigation Device) as Compared with Manual Brushing and Flossing: Randomized Controlled Pilot Trial

    PubMed Central

    Murthy, Prashanth Sadashiva; Shaik, Naseemoon; Deshmukh, Seema; Girish, M. S.

    2018-01-01

    Background: Establishing good hygiene habits are valuable for present and future oral health. Below 6 years, tooth brushing should be performed by parents, as increasing dexterity and cognition may permit supervised brushing until the child is capable of independent brushing. Aim and Objectives: The aim of the present study was to evaluate the effectiveness of modified oral irrigation device in children in terms of plaque control and to compare the effectiveness of plaque control with manual brushing with the modified oral irrigation device in children. Materials and Methods: A randomized clinical trial was performed on 12 subjects who were allocated to the two study groups. After obtaining the consent, the control group was instructed tooth brushing with regular pediatric commercially available toothbrush and the intervention group with modified oral irrigation device. Plaque scores in both groups were assessed pre- and post-brushing using modified navy plaque index. Results: The data were subjected to Descriptive statistics and Paired t-test using SPSS version 22. Intragroup comparison of mean difference of plaque score in control group and intervention group pre- and post-brushing was statistically significant. Intergroup comparison of manual brushing group with modified oral irrigation group shows P < 0.05 was statistically significant. Conclusion: Within the limitation of the present study, it has been found novel pediatric oral hygiene need Station is more effective than manual brushing since it combined the effect of brushing, flossing (water floss), and rinsing in children simultaneously and at the same time did not demand any special motor skill. PMID:29875555

  7. Comparison of anastomotic leakage and stricture formation following layered and stapler oesophagogastric anastomosis for cancer: a prospective randomized controlled trial.

    PubMed

    Zhang, Y S; Gao, B R; Wang, H J; Su, Y F; Yang, Y Z; Zhang, J H; Wang, C

    2010-01-01

    The objective of this prospective, randomized, controlled trial, conducted from May 2002 to December 2007, was to compare post-operative anastomotic leakage and stricture formation following layered manual versus stapler oesophagogastric anastomosis in patients who underwent resection of oesophageal or gastric cardia carcinoma. Patients (n = 516) were randomized to receive either layered manual or circular stapled oesophagogastric anastomosis. Mean follow-up time was > 12 months. Anastomotic leakage occurred in one (0.4%) patient in the layered group and six (2.2%) in the stapler group; no statistically significant between-group difference. After operation, two (0.8%) patients in the layered group and 13 (5.0%) in the stapler group developed a benign oesophageal stricture; the difference between the groups was statistically significant. Compared with stapler anastomosis, layered manual anastomosis may significantly reduce the incidence of anastomotic strictures. This method is easy to apply and could be used as an alternative procedure for oesophagogastric anastomosis after resection for oesophageal or cardia carcinoma.

  8. Calculating the Mean Amplitude of Glycemic Excursions from Continuous Glucose Data Using an Open-Code Programmable Algorithm Based on the Integer Nonlinear Method.

    PubMed

    Yu, Xuefei; Lin, Liangzhuo; Shen, Jie; Chen, Zhi; Jian, Jun; Li, Bin; Xin, Sherman Xuegang

    2018-01-01

    The mean amplitude of glycemic excursions (MAGE) is an essential index for glycemic variability assessment, which is treated as a key reference for blood glucose controlling at clinic. However, the traditional "ruler and pencil" manual method for the calculation of MAGE is time-consuming and prone to error due to the huge data size, making the development of robust computer-aided program an urgent requirement. Although several software products are available instead of manual calculation, poor agreement among them is reported. Therefore, more studies are required in this field. In this paper, we developed a mathematical algorithm based on integer nonlinear programming. Following the proposed mathematical method, an open-code computer program named MAGECAA v1.0 was developed and validated. The results of the statistical analysis indicated that the developed program was robust compared to the manual method. The agreement among the developed program and currently available popular software is satisfied, indicating that the worry about the disagreement among different software products is not necessary. The open-code programmable algorithm is an extra resource for those peers who are interested in the related study on methodology in the future.

  9. Validity of a manual soft tissue profile prediction method following mandibular setback osteotomy.

    PubMed

    Kolokitha, Olga-Elpis

    2007-10-01

    The aim of this study was to determine the validity of a manual cephalometric method used for predicting the post-operative soft tissue profiles of patients who underwent mandibular setback surgery and compare it to a computerized cephalometric prediction method (Dentofacial Planner). Lateral cephalograms of 18 adults with mandibular prognathism taken at the end of pre-surgical orthodontics and approximately one year after surgery were used. To test the validity of the manual method the prediction tracings were compared to the actual post-operative tracings. The Dentofacial Planner software was used to develop the computerized post-surgical prediction tracings. Both manual and computerized prediction printouts were analyzed by using the cephalometric system PORDIOS. Statistical analysis was performed by means of t-test. Comparison between manual prediction tracings and the actual post-operative profile showed that the manual method results in more convex soft tissue profiles; the upper lip was found in a more prominent position, upper lip thickness was increased and, the mandible and lower lip were found in a less posterior position than that of the actual profiles. Comparison between computerized and manual prediction methods showed that in the manual method upper lip thickness was increased, the upper lip was found in a more anterior position and the lower anterior facial height was increased as compared to the computerized prediction method. Cephalometric simulation of post-operative soft tissue profile following orthodontic-surgical management of mandibular prognathism imposes certain limitations related to the methods implied. However, both manual and computerized prediction methods remain a useful tool for patient communication.

  10. Identification of potential neuromotor mechanisms of manual therapy in patients with musculoskeletal disablement: rationale and description of a clinical trial

    PubMed Central

    Fisher, Beth E; Davenport, Todd E; Kulig, Kornelia; Wu, Allan D

    2009-01-01

    Background Many health care practitioners use a variety of hands-on treatments to improve symptoms and disablement in patients with musculoskeletal pathology. Research to date indirectly suggests a potentially broad effect of manual therapy on the neuromotor processing of functional behavior within the supraspinal central nervous system (CNS) in a manner that may be independent of modification at the level of local spinal circuits. However, the effect of treatment speed, as well as the specific mechanism and locus of CNS changes, remain unclear. Methods/Design We developed a placebo-controlled, randomized study to test the hypothesis that manual therapy procedures directed to the talocrural joint in individuals with post-acute ankle sprain induce a change in corticospinal excitability that is relevant to improve the performance of lower extremity functional behavior. Discussion This study is designed to identify potential neuromotor changes associated with manual therapy procedures directed to the appendicular skeleton, compare the relative effect of treatment speed on potential neuromotor effects of manual therapy procedures, and determine the behavioral relevance of potential neuromotor effects of manual therapy procedures. Trial Registration identifier NCT00847769. PMID:19460169

  11. Extracting data from figures with software was faster, with higher interrater reliability than manual extraction.

    PubMed

    Jelicic Kadic, Antonia; Vucic, Katarina; Dosenovic, Svjetlana; Sapunar, Damir; Puljak, Livia

    2016-06-01

    To compare speed and accuracy of graphical data extraction using manual estimation and open source software. Data points from eligible graphs/figures published in randomized controlled trials (RCTs) from 2009 to 2014 were extracted by two authors independently, both by manual estimation and with the Plot Digitizer, open source software. Corresponding authors of each RCT were contacted up to four times via e-mail to obtain exact numbers that were used to create graphs. Accuracy of each method was compared against the source data from which the original graphs were produced. Software data extraction was significantly faster, reducing time for extraction for 47%. Percent agreement between the two raters was 51% for manual and 53.5% for software data extraction. Percent agreement between the raters and original data was 66% vs. 75% for the first rater and 69% vs. 73% for the second rater, for manual and software extraction, respectively. Data extraction from figures should be conducted using software, whereas manual estimation should be avoided. Using software for data extraction of data presented only in figures is faster and enables higher interrater reliability. Copyright © 2016 Elsevier Inc. All rights reserved.

  12. A guide to best practices for Gene Ontology (GO) manual annotation

    PubMed Central

    Balakrishnan, Rama; Harris, Midori A.; Huntley, Rachael; Van Auken, Kimberly; Cherry, J. Michael

    2013-01-01

    The Gene Ontology Consortium (GOC) is a community-based bioinformatics project that classifies gene product function through the use of structured controlled vocabularies. A fundamental application of the Gene Ontology (GO) is in the creation of gene product annotations, evidence-based associations between GO definitions and experimental or sequence-based analysis. Currently, the GOC disseminates 126 million annotations covering >374 000 species including all the kingdoms of life. This number includes two classes of GO annotations: those created manually by experienced biocurators reviewing the literature or by examination of biological data (1.1 million annotations covering 2226 species) and those generated computationally via automated methods. As manual annotations are often used to propagate functional predictions between related proteins within and between genomes, it is critical to provide accurate consistent manual annotations. Toward this goal, we present here the conventions defined by the GOC for the creation of manual annotation. This guide represents the best practices for manual annotation as established by the GOC project over the past 12 years. We hope this guide will encourage research communities to annotate gene products of their interest to enhance the corpus of GO annotations available to all. Database URL: http://www.geneontology.org PMID:23842463

  13. Validity of radiographic assessment of the knee joint space using automatic image analysis.

    PubMed

    Komatsu, Daigo; Hasegawa, Yukiharu; Kojima, Toshihisa; Seki, Taisuke; Ikeuchi, Kazuma; Takegami, Yasuhiko; Amano, Takafumi; Higuchi, Yoshitoshi; Kasai, Takehiro; Ishiguro, Naoki

    2016-09-01

    The present study investigated whether there were differences between automatic and manual measurements of the minimum joint space width (mJSW) on knee radiographs. Knee radiographs of 324 participants in a systematic health screening were analyzed using the following three methods: manual measurement of film-based radiographs (Manual), manual measurement of digitized radiographs (Digital), and automatic measurement of digitized radiographs (Auto). The mean mJSWs on the medial and lateral sides of the knees were determined using each method, and measurement reliability was evaluated using intra-class correlation coefficients. Measurement errors were compared between normal knees and knees with radiographic osteoarthritis. All three methods demonstrated good reliability, although the reliability was slightly lower with the Manual method than with the other methods. On the medial and lateral sides of the knees, the mJSWs were the largest in the Manual method and the smallest in the Auto method. The measurement errors of each method were significantly larger for normal knees than for radiographic osteoarthritis knees. The mJSW measurements are more accurate and reliable with the Auto method than with the Manual or Digital method, especially for normal knees. Therefore, the Auto method is ideal for the assessment of the knee joint space.

  14. A Randomized Placebo-Controlled Trial of a School-Based Depression Prevention Program.

    ERIC Educational Resources Information Center

    Merry, Sally; McDowell, Heather; Wild, Chris J.; Bir, Julliet; Cunliffe, Rachel

    2004-01-01

    Objective: To conduct a placebo-controlled study of the effectiveness of a universal school-based depression prevention program. Method: Three hundred ninety-two students age 13 to 15 from two schools were randomized to intervention (RAP-Kiwi) and placebo programs run by teachers. RAP-Kiwi was an 11-session manual-based program derived from…

  15. Biology and Control of Insect and Related Pests of Livestock in Wyoming. MP-23.

    ERIC Educational Resources Information Center

    Lloyd, John E.

    This document provides information that a potential insecticide applicator can utilize to safely and effectively control insects and related pests of livestock. The first section of the manual discusses the general methods of preparation and application of insecticides. The second section concerns itself with the recognition of insect problems,…

  16. A 5-Year Assessment Of Shortleaf Pine And Hardwood Sprouts Relative To Three Methods Of Hardwood Control In The Arkansas Ozarks

    Treesearch

    Michael D. Cain

    2004-01-01

    Abstract - Compared with untreated checks, manual hardwood control and herbicide injection of hardwoods facilitated the development of direct seeded shortleaf pine (Pinus echinata Mill.) regeneration following a single-tree selection harvest in a mature natural stand of shortleaf pines in northwest Arkansas. Five years after...

  17. Online learning control using adaptive critic designs with sparse kernel machines.

    PubMed

    Xu, Xin; Hou, Zhongsheng; Lian, Chuanqiang; He, Haibo

    2013-05-01

    In the past decade, adaptive critic designs (ACDs), including heuristic dynamic programming (HDP), dual heuristic programming (DHP), and their action-dependent ones, have been widely studied to realize online learning control of dynamical systems. However, because neural networks with manually designed features are commonly used to deal with continuous state and action spaces, the generalization capability and learning efficiency of previous ACDs still need to be improved. In this paper, a novel framework of ACDs with sparse kernel machines is presented by integrating kernel methods into the critic of ACDs. To improve the generalization capability as well as the computational efficiency of kernel machines, a sparsification method based on the approximately linear dependence analysis is used. Using the sparse kernel machines, two kernel-based ACD algorithms, that is, kernel HDP (KHDP) and kernel DHP (KDHP), are proposed and their performance is analyzed both theoretically and empirically. Because of the representation learning and generalization capability of sparse kernel machines, KHDP and KDHP can obtain much better performance than previous HDP and DHP with manually designed neural networks. Simulation and experimental results of two nonlinear control problems, that is, a continuous-action inverted pendulum problem and a ball and plate control problem, demonstrate the effectiveness of the proposed kernel ACD methods.

  18. A work study of the CAD/CAM method and conventional manual method in the fabrication of spinal orthoses for patients with adolescent idiopathic scoliosis.

    PubMed

    Wong, M S; Cheng, J C Y; Wong, M W; So, S F

    2005-04-01

    A study was conducted to compare the CAD/CAM method with the conventional manual method in fabrication of spinal orthoses for patients with adolescent idiopathic scoliosis. Ten subjects were recruited for this study. Efficiency analyses of the two methods were performed from cast filling/ digitization process to completion of cast/image rectification. The dimensional changes of the casts/ models rectified by the two cast rectification methods were also investigated. The results demonstrated that the CAD/CAM method was faster than the conventional manual method in the studied processes. The mean rectification time of the CAD/CAM method was shorter than that of the conventional manual method by 108.3 min (63.5%). This indicated that the CAD/CAM method took about 1/3 of the time of the conventional manual to finish cast rectification. In the comparison of cast/image dimensional differences between the conventional manual method and the CAD/CAM method, five major dimensions in each of the five rectified regions namely the axilla, thoracic, lumbar, abdominal and pelvic regions were involved. There were no significant dimensional differences (p < 0.05) in 19 out of the 25 studied dimensions. This study demonstrated that the CAD/CAM system could save the time in the rectification process and offer a relatively high resemblance in cast rectification as compared with the conventional manual method.

  19. Three combinations of manual therapy techniques within naprapathy in the treatment of neck and/or back pain: a randomized controlled trial.

    PubMed

    Paanalahti, Kari; Holm, Lena W; Nordin, Margareta; Höijer, Jonas; Lyander, Jessica; Asker, Martin; Skillgate, Eva

    2016-04-23

    Manual therapy as spinal manipulation, spinal mobilization, stretching and massage are common treatment methods for neck and back pain. The objective was to compare the treatment effect on pain intensity, pain related disability and perceived recovery from a) naprapathic manual therapy (spinal manipulation, spinal mobilization, stretching and massage) to b) naprapathic manual therapy without spinal manipulation and to c) naprapathic manual therapy without stretching for male and female patients seeking care for back and/or neck pain. Participants were recruited among patients, ages 18-65, seeking care at the educational clinic of Naprapathögskolan - the Scandinavian College of Naprapathic Manual Medicine in Stockholm. The patients (n = 1057) were randomized to one of three treatment arms a) manual therapy (i.e. spinal manipulation, spinal mobilization, stretching and massage), b) manual therapy excluding spinal manipulation and c) manual therapy excluding stretching. The primary outcomes were minimal clinically important improvement in pain intensity and pain related disability. Treatments were provided by naprapath students in the seventh semester of eight total semesters. Generalized estimating equations and logistic regression were used to examine the association between the treatments and the outcomes. At 12 weeks follow-up, 64% had a minimal clinically important improvement in pain intensity and 42% in pain related disability. The corresponding chances to be improved at the 52 weeks follow-up were 58% and 40% respectively. No systematic differences in effect when excluding spinal manipulation and stretching respectively from the treatment were found over 1 year follow-up, concerning minimal clinically important improvement in pain intensity (p = 0.41) and pain related disability (p = 0.85) and perceived recovery (p = 0.98). Neither were there disparities in effect when male and female patients were analyzed separately. The effect of manual therapy for male and female patients seeking care for neck and/or back pain at an educational clinic is similar regardless if spinal manipulation or if stretching is excluded from the treatment option. Current Controlled Trials ISRCTN92249294.

  20. SU-E-T-213: Comparison of Treatment Efficiency of Gamma Knife SRS Plans for Brain Metastases with Different Planning Methods

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Feng, Y; Huang, Z; Lo, S

    2015-06-15

    Purpose: To improve Gamma Knife SRS treatment efficiency for brain metastases and compare the differences of treatment time and radiobiological effects between two different planning methods of automatic filling and manual placement of shots with inverse planning. Methods: T1-weighted MRI images with gadolinium contrast from five patients with a single brain metastatic-lesion were used in this retrospective study. Among them, two were from primary breast cancer, two from primary melanoma cancer and one from primary prostate cancer. For each patient, two plans were generated in Leksell GammaPlan10.1.1 for radiosurgical treatment with a Leksell GammaKnife Perfexion machine: one with automatic filling,more » automatic sector configuration and inverse optimization (Method1); and the other with manual placement of shots, manual setup of collimator sizes, manual setup of sector blocking and inverse optimization (Method2). Dosimetric quality of the plans was evaluated with parameters of Coverage, Selectivity, Gradient-Index and DVH. Beam-on Time, Number-of-Shots and Tumor Control Probability(TCP) were compared for the two plans while keeping their dosimetric quality very similar. Relative reduction of Beam-on Time and Number-of-Shots were calculated as the ratios among the two plans and used for quantitative analysis. Results: With very similar dosimetric and radiobiological plan quality, plans created with Method 2 had significantly reduced treatment time. Relative reduction of Beam-on Time ranged from 20% to 51 % (median:29%,p=0.001), and reduction of Number-of-Shots ranged from 5% to 67% (median:40%,p=0.0002), respectively. Time of plan creation for Method1 and Method2 was similar, approximately 20 minutes, excluding the time for tumor delineation. TCP calculated for the tumors from differential DVHs did not show significant difference between the two plans (p=0.35). Conclusion: The method of manual setup combined with inverse optimization in LGP for treatment of brain metastatic lesions with the Perfexion can achieve significantly higher time efficiency without degrading treatment quality.« less

  1. Detection of antipersonnel (AP) mines using mechatronics approach

    NASA Astrophysics Data System (ADS)

    Shahri, Ali M.; Naghdy, Fazel

    1998-09-01

    At present there are approximately 110 million land-mines scattered around the world in 64 countries. The clearance of these mines takes place manually. Unfortunately, on average for every 5000 mines cleared one mine clearer is killed. A Mine Detector Arm (MDA) using mechatronics approach is under development in this work. The robot arm imitates manual hand- prodding technique for mine detection. It inserts a bayonet into the soil and models the dynamics of the manipulator and environment parameters, such as stiffness variation in the soil to control the impact caused by contacting a stiff object. An explicit impact control scheme is applied as the main control scheme, while two different intelligent control methods are designed to deal with uncertainties and varying environmental parameters. Firstly, a neuro-fuzzy adaptive gain controller (NFAGC) is designed to adapt the force gain control according to the estimated environment stiffness. Then, an adaptive neuro-fuzzy plus PID controller is employed to switch from a conventional PID controller to neuro-fuzzy impact control (NFIC), when an impact is detected. The developed control schemes are validated through computer simulation and experimental work.

  2. Monitoring rationale, strategy, issues, and methods: UMRR-EMP LTRMP fish component

    USGS Publications Warehouse

    Ickes, Brian S.; Sauer, Jennifer S.; Rogala, James T.

    2014-01-01

    The Long Term Resource Monitoring Program (LTRMP), an element of the multiagency partnership Upper Mississippi River Restoration-Environmental Management Program, has been monitoring fishes in the Upper Mississippi River System (UMRS) for over two decades, using scientific and highly standardized methods. Today, the LTRMP’s data assets represent one of the world’s largest and most extensive datasets on a great river. Methods and procedures used over the past two decades have been documented and have proven a key tool towards gaining data that are (a) scientifically valid, (b) comparable over time, and (c) comparable over space. These procedures manuals coordinate and standardize methods, procedures, and field behaviors in the execution of long-term monitoring, permitting the informed management and control of important sources of error actually under program control. As LTRMP databases have matured in scope and accumulated more years' worth of data, their utility in research and management in the UMRS basin has increased notably. To maximize their utility, data users need not only be aware of “how the data were collected,” as portrayed in the procedures manuals, but also “why the data were collected in the way they were, at the scales they were, and in the manner that they were.” Whereas the procedures manuals contribute information as to the “how” the data were gained, this document seeks to contribute information as to the “why.” As such, this document is intended to be a companion document to the procedures manuals. Herein, we present information on the rationale for monitoring nearly one-fifth of the entire North American freshwater fish fauna (representing the greatest freshwater fish diversity on the planet at temperate latitudes); strategies employed and their reasoning; and discussions on issues associated with the sampling design itself, data arising therefrom, and uses of those data in different contexts.

  3. 40 CFR 63.4766 - How do I determine the add-on control device emission destruction or removal efficiency?

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... also use as an alternative to Method 3B, the manual method for measuring the oxygen, carbon dioxide, and carbon monoxide content of exhaust gas in ANSI/ASME PTC 19.10-1981, “Flue and Exhaust Gas Analyses [Part 10, Instruments and Apparatus]” (incorporated by reference, see § 63.14). (4) Use Method 4 of...

  4. The effect of bridge deck design methodology on crack control.

    DOT National Transportation Integrated Search

    2010-01-30

    At present, the Idaho Transportation Department (ITD) Bridge Design Manual allows engineers to use the AASHTO empirical method to : design concrete bridge decks. However, the ITD Bridge Section would like to compare their design practices to those em...

  5. Natural Language Processing As an Alternative to Manual Reporting of Colonoscopy Quality Metrics

    PubMed Central

    RAJU, GOTTUMUKKALA S.; LUM, PHILLIP J.; SLACK, REBECCA; THIRUMURTHI, SELVI; LYNCH, PATRICK M.; MILLER, ETHAN; WESTON, BRIAN R.; DAVILA, MARTA L.; BHUTANI, MANOOP S.; SHAFI, MEHNAZ A.; BRESALIER, ROBERT S.; DEKOVICH, ALEXANDER A.; LEE, JEFFREY H.; GUHA, SUSHOVAN; PANDE, MALA; BLECHACZ, BORIS; RASHID, ASIF; ROUTBORT, MARK; SHUTTLESWORTH, GLADIS; MISHRA, LOPA; STROEHLEIN, JOHN R.; ROSS, WILLIAM A.

    2015-01-01

    BACKGROUND & AIMS The adenoma detection rate (ADR) is a quality metric tied to interval colon cancer occurrence. However, manual extraction of data to calculate and track the ADR in clinical practice is labor-intensive. To overcome this difficulty, we developed a natural language processing (NLP) method to identify patients, who underwent their first screening colonoscopy, identify adenomas and sessile serrated adenomas (SSA). We compared the NLP generated results with that of manual data extraction to test the accuracy of NLP, and report on colonoscopy quality metrics using NLP. METHODS Identification of screening colonoscopies using NLP was compared with that using the manual method for 12,748 patients who underwent colonoscopies from July 2010 to February 2013. Also, identification of adenomas and SSAs using NLP was compared with that using the manual method with 2259 matched patient records. Colonoscopy ADRs using these methods were generated for each physician. RESULTS NLP correctly identified 91.3% of the screening examinations, whereas the manual method identified 87.8% of them. Both the manual method and NLP correctly identified examinations of patients with adenomas and SSAs in the matched records almost perfectly. Both NLP and manual method produce comparable values for ADR for each endoscopist as well as the group as a whole. CONCLUSIONS NLP can correctly identify screening colonoscopies, accurately identify adenomas and SSAs in a pathology database, and provide real-time quality metrics for colonoscopy. PMID:25910665

  6. Optimization of Endotracheal Tube Cuff Pressure by Monitoring CO2 Levels in the Subglottic Space in Mechanically Ventilated Patients: A Randomized Controlled Trial.

    PubMed

    Efrati, Shai; Bolotin, Gil; Levi, Leon; Zaaroor, Menashe; Guralnik, Ludmila; Weksler, Natan; Levinger, Uriel; Soroksky, Arie; Denman, William T; Gurman, Gabriel M

    2017-10-01

    Many of the complications of mechanical ventilation are related to inappropriate endotracheal tube (ETT) cuff pressure. The aim of the current study was to evaluate the effectiveness of automatic cuff pressure closed-loop control in patients under prolonged intubation, where presence of carbon dioxide (CO2) in the subglottic space is used as an indicator for leaks. The primary outcome of the study is leakage around the cuff quantified using the area under the curve (AUC) of CO2 leakage over time. This was a multicenter, prospective, randomized controlled, noninferiority trial including intensive care unit patients. All patients were intubated with the AnapnoGuard ETT, which has an extra lumen used to monitor CO2 levels in the subglottic space.The study group was connected to the AnapnoGuard system operating with cuff control adjusted automatically based on subglottic CO2 (automatic group). The control group was connected to the AnapnoGuard system, while cuff pressure was managed manually using a manometer 3 times/d (manual group). The system recorded around cuff CO2 leakage in both groups. Seventy-two patients were recruited and 64 included in the final analysis. The mean hourly around cuff CO2 leak (mm Hg AUC/h) was 0.22 ± 0.32 in the manual group and 0.09 ± 0.04 in the automatic group (P = .01) where the lower bound of the 1-sided 95% confidence interval was 0.05, demonstrating noninferiority (>-0.033). Additionally, the 2-sided 95% confidence interval was 0.010 to 0.196, showing superiority (>0.0) as well. Significant CO2 leakage (CO2 >2 mm Hg) was 0.027 ± 0.057 (mm Hg AUC/h) in the automatic group versus 0.296 ± 0.784 (mm Hg AUC/h) in the manual group (P = .025). In addition, cuff pressures were in the predefined safety range 97.6% of the time in the automatic group compared to 48.2% in the automatic group (P < .001). This study shows that the automatic cuff pressure group is not only noninferior but also superior compared to the manual cuff pressure group. Thus, the use of automatic cuff pressure control based on subglottic measurements of CO2 levels is an effective method for ETT cuff pressure optimization. The method is safe and can be easily utilized with any intubated patient.

  7. SOWFA + Super Controller User's Manual

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Fleming, P.; Gebraad, P.; Churchfield, M.

    2013-08-01

    SOWFA + Super Controller is a modification of the NREL's SOWFA tool which allows for a user to apply multiturbine or centralized wind plant control algorithms within the high-fidelity SOWFA simulation environment. The tool is currently a branch of the main SOWFA program, but will one day will be merged into a single version. This manual introduces the tool and provides examples such that a usercan implement their own super controller and set up and run simulations. The manual only discusses enough about SOWFA itself to allow for the customization of controllers and running of simulations, and details of SOWFAmore » itself are reported elsewhere Churchfield and Lee (2013); Churchfield et al. (2012). SOWFA + Super Controller, and this manual, are in alpha mode.« less

  8. FAA Air Traffic Control Operations Concepts. Volume 5. ATCT/TCCC (airport Traffic Control Tower/Tower Control Computer Complex) Tower Controllers

    DTIC Science & Technology

    1988-07-29

    Departure List. T1.1.4.13 RESEQUENCE FOE MANUALLY 3.7.2.2.1.1.2.2-00 ARRIVAL LIST 457 3.7.2.2.1,1.2.2-11 b. Ordering - In manual ordering , the 457 a...3.7.2.2.1.1.2.3-12 b. Ordering - In manual ordering , the 457 controller shall have the capability to put a new FOE in the appropriate place in a sublist...3.7.2.2.1.1.2.2-00 ARRIVAL LIST 457 3.7.2.2.1.1.2.2-11 b. Ordering - In manual ordering , the 457 controller snall have the capability to put a new FOE in

  9. VDOT manual of practice for planning stormwater management.

    DOT National Transportation Integrated Search

    1992-01-01

    The final report is in the form of a manual of practice for the VDOT to use in planning its stormwater management strategies. The manual was proposed to aid in the selection and design of erosion control practices and stormwater control practices for...

  10. MAC/GMC 4.0 User's Manual: Keywords Manual. Volume 2

    NASA Technical Reports Server (NTRS)

    Bednarcyk, Brett A.; Arnold, Steven M.

    2002-01-01

    This document is the second volume in the three volume set of User's Manuals for the Micromechanics Analysis Code with Generalized Method of Cells Version 4.0 (MAC/GMC 4.0). Volume 1 is the Theory Manual, this document is the Keywords Manual, and Volume 3 is the Example Problem Manual. MAC/GMC 4.0 is a composite material and laminate analysis software program developed at the NASA Glenn Research Center. It is based on the generalized method of cells (GMC) micromechanics theory, which provides access to the local stress and strain fields in the composite material. This access grants GMC the ability to accommodate arbitrary local models for inelastic material behavior and various types of damage and failure analysis. MAC/GMC 4.0 has been built around GMC to provide the theory with a user-friendly framework, along with a library of local inelastic, damage, and failure models. Further, applications of simulated thermo-mechanical loading, generation of output results, and selection of architectures to represent the composite material have been automated in MAC/GMC 4.0. Finally, classical lamination theory has been implemented within MAC/GMC 4.0 wherein GMC is used to model the composite material response of each ply. Consequently, the full range of GMC composite material capabilities is available for analysis of arbitrary laminate configurations as well. This volume describes the basic information required to use the MAC/GMC 4.0 software, including a 'Getting Started' section, and an in-depth description of each of the 22 keywords used in the input file to control the execution of the code.

  11. Monitoring post-fire vegetation rehabilitation projects: A common approach for non-forested ecosystems

    USGS Publications Warehouse

    Wirth, Troy A.; Pyke, David A.

    2007-01-01

    Emergency Stabilization and Rehabilitation (ES&R) and Burned Area Emergency Response (BAER) treatments are short-term, high-intensity treatments designed to mitigate the adverse effects of wildfire on public lands. The federal government expends significant resources implementing ES&R and BAER treatments after wildfires; however, recent reviews have found that existing data from monitoring and research are insufficient to evaluate the effects of these activities. The purpose of this report is to: (1) document what monitoring methods are generally used by personnel in the field; (2) describe approaches and methods for post-fire vegetation and soil monitoring documented in agency manuals; (3) determine the common elements of monitoring programs recommended in these manuals; and (4) describe a common monitoring approach to determine the effectiveness of future ES&R and BAER treatments in non-forested regions. Both qualitative and quantitative methods to measure effectiveness of ES&R treatments are used by federal land management agencies. Quantitative methods are used in the field depending on factors such as funding, personnel, and time constraints. There are seven vegetation monitoring manuals produced by the federal government that address monitoring methods for (primarily) vegetation and soil attributes. These methods vary in their objectivity and repeatability. The most repeatable methods are point-intercept, quadrat-based density measurements, gap intercepts, and direct measurement of soil erosion. Additionally, these manuals recommend approaches for designing monitoring programs for the state of ecosystems or the effect of management actions. The elements of a defensible monitoring program applicable to ES&R and BAER projects that most of these manuals have in common are objectives, stratification, control areas, random sampling, data quality, and statistical analysis. The effectiveness of treatments can be determined more accurately if data are gathered using an approach that incorporates these six monitoring program design elements and objectives, as well as repeatable procedures to measure cover, density, gap intercept, and soil erosion within each ecoregion and plant community. Additionally, using a common monitoring program design with comparable methods, consistently documenting results, and creating and maintaining a central database for query and reporting, will ultimately allow a determination of the effectiveness of post-fire rehabilitation activities region-wide.

  12. Antifungal Susceptibility Testing in HIV/AIDS Patients: a Comparison Between Automated Machine and Manual Method.

    PubMed

    Nelwan, Erni J; Indrasanti, Evi; Sinto, Robert; Nurchaida, Farida; Sosrosumihardjo, Rustadi

    2016-01-01

    to evaluate the performance of Vitek2 compact machine (Biomerieux Inc. ver 04.02, France) in reference to manual methods for susceptibility test for Candida resistance among HIV/AIDS patients. a comparison study to evaluate Vitek2 compact machine (Biomerieux Inc. ver 04.02, France) in reference to manual methods for susceptibility test for Candida resistance among HIV/AIDS patient was done. Categorical agreement between manual disc diffusion and Vitek2 machine was calculated using predefined criteria. Time to susceptibility result for automated and manual methods were measured. there were 137 Candida isolates comprising eight Candida species with C.albicans and C. glabrata as the first (56.2%) and second (15.3%) most common species, respectively. For fluconazole drug, among the C. albicans, 2.6% was found resistant on manual disc diffusion methods and no resistant was determined by Vitek2 machine; whereas 100% C. krusei was identified as resistant on both methods. Resistant patterns for C. glabrata to fluconazole, voriconazole and amphotericin B were 52.4%, 23.8%, 23.8% vs. 9.5%, 9.5%, 4.8% respectively between manual diffusion disc methods and Vitek2 machine. Time to susceptibility result for automated methods compared to Vitex2 machine was shorter for all Candida species. there is a good categorical agreement between manual disc diffusion and Vitek2 machine, except for C. glabrata for measuring the antifungal resistant. Time to susceptibility result for automated methods is shorter for all Candida species.

  13. Proceedings, 13th Annual Conference on Manual Control

    NASA Technical Reports Server (NTRS)

    1977-01-01

    Theoretical aspects of manual control theory are discussed. Specific topics covered include: tracking; performance, attention allocation, and mental load; surface vehicle control; monitoring behavior and supervisory control; manipulators and prosthetics; aerospace vehicle control; motion and visual cues; and displays and controls.

  14. Teaching artificial neural systems to drive: Manual training techniques for autonomous systems

    NASA Technical Reports Server (NTRS)

    Shepanski, J. F.; Macy, S. A.

    1987-01-01

    A methodology was developed for manually training autonomous control systems based on artificial neural systems (ANS). In applications where the rule set governing an expert's decisions is difficult to formulate, ANS can be used to extract rules by associating the information an expert receives with the actions taken. Properly constructed networks imitate rules of behavior that permits them to function autonomously when they are trained on the spanning set of possible situations. This training can be provided manually, either under the direct supervision of a system trainer, or indirectly using a background mode where the networks assimilates training data as the expert performs its day-to-day tasks. To demonstrate these methods, an ANS network was trained to drive a vehicle through simulated freeway traffic.

  15. A clinicomicrobiological study to evaluate the efficacy of manual and powered toothbrushes among autistic patients

    PubMed Central

    Vajawat, Mayuri; Deepika, P. C.; Kumar, Vijay; Rajeshwari, P.

    2015-01-01

    Aim: To compare the efficacy of powered toothbrushes in improving gingival health and reducing salivary red complex counts as compared to manual toothbrushes, among autistic individuals. Materials and Methods: Forty autistics was selected. Test group received powered toothbrushes, and control group received manual toothbrushes. Plaque index and gingival index were recorded. Unstimulated saliva was collected for analysis of red complex organisms using polymerase chain reaction. Results: A statistically significant reduction in the plaque scores was seen over a period of 12 weeks in both the groups (P < 0.001 for tests and P = 0.002 for controls). This reduction was statistically more significant in the test group (P = 0.024). A statistically significant reduction in the gingival scores was seen over a period of 12 weeks in both the groups (P < 0.001 for tests and P = 0.001 for controls). This reduction was statistically more significant in the test group (P = 0.042). No statistically significant reduction in the detection rate of red complex organisms were seen at 4 weeks in both the groups. Conclusion: Powered toothbrushes result in a significant overall improvement in gingival health when constant reinforcement of oral hygiene instructions is given. PMID:26681855

  16. The cost-effectiveness of three methods of disseminating information to improve medical male circumcision in Uganda

    PubMed Central

    Karamagi, Esther; Kigonya, Angella; Lawino, Anna; Marquez, Lani; Lunsford, Sarah Smith; Twinomugisha, Albert

    2018-01-01

    Background Uganda is working to increase voluntary medical male circumcision (VMMC) to prevent HIV infection. To support VMMC quality improvement, this study compared three methods of disseminating information to facilities on how to improve VMMC quality: M—providing a written manual; MH—providing the manual plus a handover meeting in which clinicians shared advice on implementing key changes and participated in group discussion; and MHC—manual, handover meeting, and three site visits to the facility in which a coach provided individualized guidance and mentoring on improvement. We determined the different effects these had on compliance with indicators of quality of care. Methods This controlled pre-post intervention study randomized health facility groups to receive M, MH, or MHC. Observations of VMMCs performance determined compliance with quality indicators. Intervention costs per patient receiving VMMC were used in a decision-tree cost-effectiveness model to calculate the incremental cost per additional patient treated to compliance with indicators of informed consent, history taking, anesthesia administration, and post-operative instructions. Results The most intensive method (MHC) cost $28.83 per patient and produced the biggest gains in history taking (35% improvement), anesthesia administration (20% improvement), and post-operative instructions (37% improvement). The least intensive method (M; $1.13 per patient) was most efficient because it produced small gains for a very low cost. The handover meeting (MH) was the most expensive among the three interventions but did not have a corresponding positive effect on quality. Conclusion Health workers in facilities that received the VMMC improvement manual and participated in the handover meeting and coaching visits showed more improvement in VMMC quality indicators than those in the other two intervention groups. Providing the manual alone cost the least but was also the least effective in achieving improvements. The MHC intervention is recommended for broader implementation to improve VMMC quality in Uganda. PMID:29672578

  17. Tele-Manipulation with Two Asymmetric Slaves: Two Operators Perform Better Than One.

    PubMed

    van Oosterhout, Jeroen; Heemskerk, Cock J M; de Baar, Marco R; van der Helm, Frans C T; Abbink, David A

    2018-01-01

    Certain tele-manipulation tasks require manipulation by two asymmetric slaves, for example, a crane for hoisting and a dexterous robotic arm for fine manipulation. It is unclear how to best design human-in-the-loop control over two asymmetric slaves. The goal of this paper is to quantitatively compare the standard approach of two co-operating operators that each control a single subtask, to a single operator performing bi-manual control over the two subtasks, and a uni-manual control approach. In a human factors experiment, participants performed a heavy load maneuvering and mounting task using a vertical crane and a robotic arm. We hypothesize that bi-manual control yields worse task performance and control activity compared to co-operation, because of conflicting spatial and temporal constraints. Literature suggests that uni-manual operators should perform better than co-operation, as co-operators critically depend on each other's actions. However, other literature provides evidence that individual operators have limited capabilities in controlling asymmetric axes of two dynamic systems. The results show that the two co-operators perform the maneuvering and mounting task faster than either bi- or uni-manual operators. Compared to co-operators, uni-manual operators required more control activity for the vertical crane and less for the robotic arm. In conclusion, this study suggests that when controlling two asymmetric slaves, a co-operating pair of operators performs better than a single operator.

  18. PID self tuning control based on Mamdani fuzzy logic control for quadrotor stabilization

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Priyambodo, Tri Kuntoro, E-mail: mastri@ugm.ac.id; Putra, Agfianto Eko; Department of Computer Science and Electronics, Universitas Gadjah Mada, Yogyakarta

    Quadrotor as one type of UAV have the ability to perform Vertical Take Off and Landing (VTOL). It allows the Quadrotor to be stationary hovering in the air. PID (Proportional Integral Derivative) control system is one of the control methods that are commonly used. It is usually used to optimize the Quadrotor stabilization at least based on the three Eulerian angles (roll, pitch, and yaw) as input parameters for the control system. The three constants of PID can be obtained in various methods. The simplest method is tuning manually. This method has several weaknesses. For example if the three constantsmore » are not exact, the resulting response will deviate from the desired result. By combining the methods of PID with fuzzy logic systems where human expertise is implemented into the machine language is expected to further optimize the control system.« less

  19. The effects of voice and manual control mode on dual task performance

    NASA Technical Reports Server (NTRS)

    Wickens, C. D.; Zenyuh, J.; Culp, V.; Marshak, W.

    1986-01-01

    Two fundamental principles of human performance, compatibility and resource competition, are combined with two structural dichotomies in the human information processing system, manual versus voice output, and left versus right cerebral hemisphere, in order to predict the optimum combination of voice and manual control with either hand, for time-sharing performance of a dicrete and continuous task. Eight right handed male subjected performed a discrete first-order tracking task, time-shared with an auditorily presented Sternberg Memory Search Task. Each task could be controlled by voice, or by the left or right hand, in all possible combinations except for a dual voice mode. When performance was analyzed in terms of a dual-task decrement from single task control conditions, the following variables influenced time-sharing efficiency in diminishing order of magnitude, (1) the modality of control, (discrete manual control of tracking was superior to discrete voice control of tracking and the converse was true with the memory search task), (2) response competition, (performance was degraded when both tasks were responded manually), (3) hemispheric competition, (performance degraded whenever two tasks were controlled by the left hemisphere) (i.e., voice or right handed control). The results confirm the value of predictive models invoice control implementation.

  20. AGARD Flight Test Instrumentation Series. Volume 14. The Analysis of Random Data

    DTIC Science & Technology

    1981-11-01

    obtained at arbitrary times during a number of flights. No constraints have been placed upon the controlling parameters, so that the process is non ...34noisy" environment controlling a non -linear system (the aircraft) using a redundant net of control parameters. when aircraft were flown manually with...structure. Cuse 2. Non -Stationary Measurements. When the 114S value of a random signal varies with parameters which cannot be controlled , then the method

  1. Testing an automated method to estimate ground-water recharge from streamflow records

    USGS Publications Warehouse

    Rutledge, A.T.; Daniel, C.C.

    1994-01-01

    The computer program, RORA, allows automated analysis of streamflow hydrographs to estimate ground-water recharge. Output from the program, which is based on the recession-curve-displacement method (often referred to as the Rorabaugh method, for whom the program is named), was compared to estimates of recharge obtained from a manual analysis of 156 years of streamflow record from 15 streamflow-gaging stations in the eastern United States. Statistical tests showed that there was no significant difference between paired estimates of annual recharge by the two methods. Tests of results produced by the four workers who performed the manual method showed that results can differ significantly between workers. Twenty-two percent of the variation between manual and automated estimates could be attributed to having different workers perform the manual method. The program RORA will produce estimates of recharge equivalent to estimates produced manually, greatly increase the speed od analysis, and reduce the subjectivity inherent in manual analysis.

  2. Objective Model Selection for Identifying the Human Feedforward Response in Manual Control.

    PubMed

    Drop, Frank M; Pool, Daan M; van Paassen, Marinus Rene M; Mulder, Max; Bulthoff, Heinrich H

    2018-01-01

    Realistic manual control tasks typically involve predictable target signals and random disturbances. The human controller (HC) is hypothesized to use a feedforward control strategy for target-following, in addition to feedback control for disturbance-rejection. Little is known about human feedforward control, partly because common system identification methods have difficulty in identifying whether, and (if so) how, the HC applies a feedforward strategy. In this paper, an identification procedure is presented that aims at an objective model selection for identifying the human feedforward response, using linear time-invariant autoregressive with exogenous input models. A new model selection criterion is proposed to decide on the model order (number of parameters) and the presence of feedforward in addition to feedback. For a range of typical control tasks, it is shown by means of Monte Carlo computer simulations that the classical Bayesian information criterion (BIC) leads to selecting models that contain a feedforward path from data generated by a pure feedback model: "false-positive" feedforward detection. To eliminate these false-positives, the modified BIC includes an additional penalty on model complexity. The appropriate weighting is found through computer simulations with a hypothesized HC model prior to performing a tracking experiment. Experimental human-in-the-loop data will be considered in future work. With appropriate weighting, the method correctly identifies the HC dynamics in a wide range of control tasks, without false-positive results.

  3. Structural Pest Control.

    ERIC Educational Resources Information Center

    Kahn, M. S.; Hoffman, W. M.

    This manual is designed for those who seek certification as pesticide applicators for industrial, institutional, structural, and health-related pest control. It is divided into six sections covering general pest control, wood-destroying organisms, bird control, fumigation, rodent control, and industrial weed control. The manual gives information…

  4. High-occupancy vehicle guidelines for planning, design and operations

    DOT National Transportation Integrated Search

    2003-08-01

    These guidelines are not intended to supersede Caltrans : Transportation Planning Manual, Project Development : Procedures Manual, Highway Design Manual, Manual : on Uniform Traffic Control Devices (MUTCD) and : California Supplement to the MUTCD ...

  5. Manual Planimetry of the Medial Temporal Lobe Versus Automated Volumetry of the Hippocampus in the Diagnosis of Alzheimer's Disease.

    PubMed

    Menéndez González, Manuel; Suárez-Sanmartin, Esther; García, Ciara; Martínez-Camblor, Pablo; Westman, Eric; Simmons, Andy

    2016-03-26

    Though a disproportionate rate of atrophy in the medial temporal lobe (MTA) represents a reliable marker of Alzheimer's disease (AD) pathology, measurement of the MTA is not currently widely used in daily clinical practice. This is mainly because the methods available to date are sophisticated and difficult to implement in clinical practice (volumetric methods), are poorly explored (linear and planimetric methods), or lack objectivity (visual rating). Here, we aimed to compare the results of a manual planimetric measure (the yearly rate of absolute atrophy of the medial temporal lobe, 2D-yrA-MTL) with the results of an automated volumetric measure (the yearly rate of atrophy of the hippocampus, 3D-yrA-H). A series of 1.5T MRI studies on 290 subjects in the age range of 65-85 years, including patients with AD (n = 100), mild cognitive impairment (MCI) (n = 100), and matched controls (n = 90) from the AddNeuroMed study, were examined by two independent subgroups of researchers: one in charge of volumetric measures and the other in charge of planimetric measures. The means of both methods were significantly different between AD and the other two diagnostic groups. In the differential diagnosis of AD against controls, 3D-yrA-H performed significantly better than 2D-yrA-MTL while differences were not statistically significant in the differential diagnosis of AD against MCI. Automated volumetry of the hippocampus is superior to manual planimetry of the MTL in the diagnosis of AD. Nevertheless, the 2D-yrAMTL is a simpler method that could be easily implemented in clinical practice when volumetry is not available.

  6. Regulation of dynamic postural control to attend manual steadiness constraints.

    PubMed

    Teixeira, Luis Augusto; Coutinho, Joane Figueiredo Serpa; Coelho, Daniel Boari

    2018-05-02

    In daily living activities, performance of spatially accurate manual movements in upright stance depends on postural stability. In the present investigation, we aimed to evaluate the effect of the required manual steadiness (task constraint) on the regulation of dynamic postural control. A single group of young participants (n=20) were evaluated in the performance of a dual posturo-manual task of balancing on a platform oscillating in sinusoidal translations at 0.4 Hz (low) or 1 Hz (high) frequencies while stabilizing a cylinder on a handheld tray. Manual task constraint was manipulated by comparing the conditions of keeping the cylinder stationary on its flat or round side, corresponding to low and high manual task constraints, respectively. Results showed that in the low oscillation frequency the high manual task constraint led to lower oscillation amplitudes of the head, center of mass, and tray, in addition to higher relative phase values between ankle/hip-shoulder oscillatory rotations and between center of mass/center of pressure-feet oscillations as compared to values observed in the low manual task constraint. Further analyses showed that the high manual task constraint also affected variables related to both postural (increased amplitudes of center of pressure oscillation) and manual (increased amplitude of shoulder rotations) task components in the high oscillation frequency. These results suggest that control of a dynamic posturo-manual task is modulated in distinct parameters to attend the required manual steadiness in a complex and flexible way.

  7. Voxel-based Gaussian naïve Bayes classification of ischemic stroke lesions in individual T1-weighted MRI scans.

    PubMed

    Griffis, Joseph C; Allendorfer, Jane B; Szaflarski, Jerzy P

    2016-01-15

    Manual lesion delineation by an expert is the standard for lesion identification in MRI scans, but it is time-consuming and can introduce subjective bias. Alternative methods often require multi-modal MRI data, user interaction, scans from a control population, and/or arbitrary statistical thresholding. We present an approach for automatically identifying stroke lesions in individual T1-weighted MRI scans using naïve Bayes classification. Probabilistic tissue segmentation and image algebra were used to create feature maps encoding information about missing and abnormal tissue. Leave-one-case-out training and cross-validation was used to obtain out-of-sample predictions for each of 30 cases with left hemisphere stroke lesions. Our method correctly predicted lesion locations for 30/30 un-trained cases. Post-processing with smoothing (8mm FWHM) and cluster-extent thresholding (100 voxels) was found to improve performance. Quantitative evaluations of post-processed out-of-sample predictions on 30 cases revealed high spatial overlap (mean Dice similarity coefficient=0.66) and volume agreement (mean percent volume difference=28.91; Pearson's r=0.97) with manual lesion delineations. Our automated approach agrees with manual tracing. It provides an alternative to automated methods that require multi-modal MRI data, additional control scans, or user interaction to achieve optimal performance. Our fully trained classifier has applications in neuroimaging and clinical contexts. Copyright © 2015 Elsevier B.V. All rights reserved.

  8. 40 CFR 63.4166 - How do I determine the add-on control device emission destruction or removal efficiency?

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... also use as an alternative to Method 3B, the manual method for measuring the oxygen, carbon dioxide, and carbon monoxide content of exhaust gas in ANSI/ASME, PTC 19.10-1981, “Flue and Exhaust Gas Analyses” (incorporated by reference, see § 63.14). (4) Use Method 4 of appendix A to 40 CFR part 60 to...

  9. Sixteenth Annual Conference on Manual Control

    NASA Technical Reports Server (NTRS)

    1982-01-01

    Manual control is discussed in terms of operator modeling, measurement of human response, mental workload, pilot/operator opinion, effects of motion, aircraft displays, supervisory control, automobile driving, and remote manipulation.

  10. Scanning electron microscopic evaluation of the influence of manual and mechanical glide path on the surface of nickel-titanium rotary instruments in moderately curved root canals: An in-vivo study

    PubMed Central

    Patel, Dishant; Bashetty, Kusum; Srirekha, A.; Archana, S.; Savitha, B.; Vijay, R.

    2016-01-01

    Aim: The aim of this study was to evaluate the influence of manual versus mechanical glide path (GP) on the surface changes of two different nickel-titanium rotary instruments used during root canal therapy in a moderately curved root canal. Materials and Methods: Sixty systemically healthy controls were selected for the study. Controls were divided randomly into four groups: Group 1: Manual GP followed by RaCe rotary instruments, Group 2: Manual GP followed by HyFlex rotary instruments, Group 3: Mechanical GP followed by RaCe rotary instruments, Group 4: Mechanical GP followed by HyFlex rotary instruments. After access opening, GP was prepared and rotary instruments were used according to manufacturer's instructions. All instruments were evaluated for defects under standard error mean before their use and after a single use. The scorings for the files were given at apical and middle third. Statistical Analysis Used: Chi-squared test was used. Results: The results showed that there is no statistical difference between any of the groups. Irrespective of the GP and rotary files used, more defects were present in the apical third when compared to middle third of the rotary instrument. Conclusion: Within the limitations of this study, it can be concluded that there was no effect of manual or mechanical GP on surface defects of subsequent rotary file system used. PMID:27994317

  11. DESIGN MANUAL: PHOSPHORUS REMOVAL

    EPA Science Inventory

    This manual summarizes process design information for the best developed methods for removing phosphorus from wastewater. his manual discusses several proven phosphorus removal methods, including phosphorus removal obtainable through biological activity as well as chemical precip...

  12. Disability pension by occupational class - the impact of work-related factors: The Hordaland Health Study Cohort

    PubMed Central

    2011-01-01

    Background The social gradient in disability pension is well recognized, however mechanisms accounting for the gradient are largely unknown. The aim of this study was to examine the association between occupational class and subsequent disability pension among middle-aged men and women, and to what extent work-related factors accounted for the association. Methods A subsample (N = 7031) of the population-based Hordaland Health Study (HUSK) conducted in 1997-99, provided self-reported information on health and work-related factors, and were grouped in four strata by Erikson, Goldthorpe and Portocareros occupational class scheme. The authors obtained follow-up data on disability pension by linking the health survey to national registries of benefit (FD-trygd). They employed Cox regression analysis and adjusted for gender, health (medical conditions, mental health, self-perceived health, somatic symptoms) and work-related factors (working hours, years in current occupation, physical demands, job demands, job control). Results A strong gradient in disability pension by occupational class was found. In the fully adjusted model the risk (hazard ratio) ranged from 1.41 (95% CI 0.84 to 2.33) in the routine non-manual class, 1.87 (95% CI 1.07 to 3.27) in the skilled manual class and 2.12 (95% CI 1.14 to 3.95) in the unskilled manual class, employing the administrator and professional class as reference. In the gender and health-adjusted model work-related factors mediated the impact of occupational class on subsequent disability pension with 5% in the routine non-manual class, 26% in the skilled manual class and 24% in the unskilled manual class. The impact of job control and physical demands was modest, and mainly seen among skilled and unskilled manual workers. Conclusions Workers in the skilled and unskilled manual classes had a substantial unexplained risk of disability pension. Work-related factors only had a moderate impact on the disability risk. Literature indicates an accumulation of hazards in the manual classes. This should be taken into account when interpreting the gradient in disability pension. PMID:21619716

  13. Effects of Intermittent Theta Burst Stimulation on Manual Dexterity and Motor Imagery in Patients with Multiple Sclerosis: A Quasi-Experimental Controlled Study

    PubMed Central

    Azin, Mahdieh; Zangiabadi, Nasser; Iranmanesh, Farhad; Baneshi, Mohammad Reza; Banihashem, Seyedshahab

    2016-01-01

    Background Intermittent theta burst stimulation (iTBS) is a repetitive transcranial magnetic stimulation (rTMS) protocol that influences cortical excitability and motor function recovery. Objectives This study aimed to investigate the effects of iTBS on manual dexterity and hand motor imagery in multiple sclerosis (MS) patients. Methods Thirty-six MS patients were non-randomly assigned into sham (control) or iTBS groups. Then, iTBS was delivered to the primary motor cortex for ten days over two consecutive weeks. The patients’ manual dexterity was assessed using the nine-hole peg test (9HPT) and the Box and Block Test (BBT), while the hand motor imagery was assessed with the hand mental rotation task (HMRT). Results iTBS group showed a reduction in the time required to complete the 9HPT (mean difference = -3.05, P = 0.002), and an increase in the number of blocks transferred in one minute in the BBT (mean difference = 8.9, P = 0.001) when compared to the control group. Furthermore, there was no significant difference between the two groups in terms of the reaction time (P = 0.761) and response accuracy rate (P = 0.482) in the HMRT. Conclusions When iTBS was applied over the primary motor cortex, it significantly improved manual dexterity, but had no significant effect on the hand motor imagery ability in MS patients. PMID:28180015

  14. Child Centred Approach to Climate Change and Health Adaptation through Schools in Bangladesh: A Cluster Randomised Intervention Trial

    PubMed Central

    Kabir, Md Iqbal; Rahman, Md Bayzidur; Smith, Wayne; Lusha, Mirza Afreen Fatima; Milton, Abul Hasnat

    2015-01-01

    Background Bangladesh is one of the most vulnerable countries to climate change. People are getting educated at different levels on how to deal with potential impacts. One such educational mode was the preparation of a school manual, for high school students on climate change and health protection endorsed by the National Curriculum and Textbook Board, which is based on a 2008 World Health Organization manual. The objective of this study was to test the effectiveness of the manual in increasing the knowledge level of the school children about climate change and health adaptation. Methods This cluster randomized intervention trial involved 60 schools throughout Bangladesh, with 3293 secondary school students participating. School upazilas (sub-districts) were randomised into intervention and control groups, and two schools from each upazila were randomly selected. All year seven students from both groups of schools sat for a pre-test of 30 short questions of binary response. A total of 1515 students from 30 intervention schools received the intervention through classroom training based on the school manual and 1778 students of the 30 control schools did not get the manual but a leaflet on climate change and health issues. Six months later, a post-intervention test of the same questionnaire used in the pre-test was performed at both intervention and control schools. The pre and post test scores were analysed along with the demographic data by using random effects model. Results None of the various school level and student level variables were significantly different between the control and intervention group. However, the intervention group had a 17.42% (95% CI: 14.45 to 20.38, P = <0.001) higher score in the post-test after adjusting for pre-test score and other covariates in a multi-level linear regression model. Conclusions These results suggest that school-based intervention for climate change and health adaptation is effective for increasing the knowledge level of school children on this topic. PMID:26252381

  15. Development of a short course : manual on uniform traffic control devices for the Alabama Department of Transportation

    DOT National Transportation Integrated Search

    2002-05-31

    This project developed a one-day short course on the Manual on Uniform Manual Traffic Control Devices (MUTCD) for the Alabama Department of Transportation (ALDOT). Portions of the MUTCD are changed from time to time, and in 2001a significantly revise...

  16. Speech versus manual control of camera functions during a telerobotic task

    NASA Technical Reports Server (NTRS)

    Bierschwale, John M.; Sampaio, Carlos E.; Stuart, Mark A.; Smith, Randy L.

    1993-01-01

    This investigation has evaluated the voice-commanded camera control concept. For this particular task, total voice control of continuous and discrete camera functions was significantly slower than manual control. There was no significant difference between voice and manual input for several types of errors. There was not a clear trend in subjective preference of camera command input modality. Task performance, in terms of both accuracy and speed, was very similar across both levels of experience.

  17. A corrosion control manual for rail rapid transit

    NASA Technical Reports Server (NTRS)

    Gilbert, L. O.; Fitzgerald, J. F., II; Menke, J. T.

    1982-01-01

    In 1979, during the planning stage of the Metropolitan Dade County Transit System, the need was expressed for a corrosion control manual oriented to urban rapid transit system use. This manual responds to that need. The objective of the manual is to aid rail rapid transit agencies by providing practical solutions to selected corrosion problems. The scope of the manual encompasses corrosion problems of the facilities of rapid transit systems: structures and tracks, platforms and stations, power and signals, and cars. It also discusses stray electric current corrosion. Both design and maintenance solutions are provided for each problem. Also included are descriptions of the types of corrosion and their causes, descriptions of rapid transit properties, a list of corrosion control committees and NASA, DOD, and ASTM specifications and design criteria to which reference is made in the manual. A bibliography of papers and excerpts of reports and a glossary of frequency used terms are provided.

  18. Auto-tuning for NMR probe using LabVIEW

    NASA Astrophysics Data System (ADS)

    Quen, Carmen; Pham, Stephanie; Bernal, Oscar

    2014-03-01

    Typical manual NMR-tuning method is not suitable for broadband spectra spanning several megahertz linewidths. Among the main problems encountered during manual tuning are pulse-power reproducibility, baselines, and transmission line reflections, to name a few. We present a design of an auto-tuning system using graphic programming language, LabVIEW, to minimize these problems. The program uses a simplified model of the NMR probe conditions near perfect tuning to mimic the tuning process and predict the position of the capacitor shafts needed to achieve the desirable impedance. The tuning capacitors of the probe are controlled by stepper motors through a LabVIEW/computer interface. Our program calculates the effective capacitance needed to tune the probe and provides controlling parameters to advance the motors in the right direction. The impedance reading of a network analyzer can be used to correct the model parameters in real time for feedback control.

  19. Method and apparatus for preloading a joint by remotely operable means

    NASA Technical Reports Server (NTRS)

    Kahn, Jon B. (Inventor)

    1993-01-01

    The invention is a method and apparatus for joining structures, an active structure and a passive structure, and imposing a tensile pre-load on the joint by a remotely operable mechanism comprising a heat contractible joining element. The method and apparatus include mounting on the structure, a probe shaft of material which is transformable from an expanded length to a contracted length when heated to a specific temperature range. The shaft is provided with a probe head which is receivable in a receptacle opening formed in the passive structure, when the active structure is moved into engagement therewith by an appropriate manipulator mechanism. A latching system mounted on the structure adjacent to the receptacle opening captures the probe head, when the probe head is inserted a predetermined amount. A heating coil on the shaft is energizable by remote control for heating the shaft to a temperature range which transforms the shaft to its contracted length, whereby a latching shoulder thereof engages latching elements of the latching system and imposes a tensile preload on the structural joint. Provision is also made for manually adjusting the probe head on the shaft to allow for manual detachment of the structures or manual preloading of the structural joint.

  20. Method and apparatus for preloading a joint by remotely operable means

    NASA Technical Reports Server (NTRS)

    Shelton, Robert O. (Inventor)

    1992-01-01

    The invention is a method and apparatus for joining structures, an active structure and a passive structure, and imposing a tensile pre-load on the joint by a remotely operable mechanism comprising a heat contractible joining element. The method and apparatus include mounting on the structure, a probe shaft of material which is transformable from an expanded length to a contracted length when heated to a specific temperature range. The shaft is provided with a probe head which is receivable in a receptacle opening formed in the passive structure, when the active structure is moved into engagement therewith by an appropriate manipulator mechanism. A latching system mounted on the structure adjacent to the receptacle opening captures the probe head, when the probe head is inserted a predetermined amount. A heating coil on the shaft is energizable by remote control for heating the shaft to a temperature range which transforms the shaft to its contracted length, whereby a latching shoulder thereof engages latching elements of the latching system and imposes a tensile preload on the structural joint. Provision is also made for manually adjusting the probe head on the shaft to allow for manual detachment of the structures or manual preloading of the structural joint.

  1. Computer numeric control generation of toric surfaces

    NASA Astrophysics Data System (ADS)

    Bradley, Norman D.; Ball, Gary A.; Keller, John R.

    1994-05-01

    Until recently, the manufacture of toric ophthalmic lenses relied largely upon expensive, manual techniques for generation and polishing. Recent gains in computer numeric control (CNC) technology and tooling enable lens designers to employ single- point diamond, fly-cutting methods in the production of torics. Fly-cutting methods continue to improve, significantly expanding lens design possibilities while lowering production costs. Advantages of CNC fly cutting include precise control of surface geometry, rapid production with high throughput, and high-quality lens surface finishes requiring minimal polishing. As accessibility and affordability increase within the ophthalmic market, torics promise to dramatically expand lens design choices available to consumers.

  2. Speech versus manual control of camera functions during a telerobotic task

    NASA Technical Reports Server (NTRS)

    Bierschwale, John M.; Sampaio, Carlos E.; Stuart, Mark A.; Smith, Randy L.

    1989-01-01

    Voice input for control of camera functions was investigated in this study. Objective were to (1) assess the feasibility of a voice-commanded camera control system, and (2) identify factors that differ between voice and manual control of camera functions. Subjects participated in a remote manipulation task that required extensive camera-aided viewing. Each subject was exposed to two conditions, voice and manual input, with a counterbalanced administration order. Voice input was found to be significantly slower than manual input for this task. However, in terms of remote manipulator performance errors and subject preference, there was no difference between modalities. Voice control of continuous camera functions is not recommended. It is believed that the use of voice input for discrete functions, such as multiplexing or camera switching, could aid performance. Hybrid mixes of voice and manual input may provide the best use of both modalities. This report contributes to a better understanding of the issues that affect the design of an efficient human/telerobot interface.

  3. Experimental analysis of drilling process in cortical bone.

    PubMed

    Wang, Wendong; Shi, Yikai; Yang, Ning; Yuan, Xiaoqing

    2014-02-01

    Bone drilling is an essential part in orthopaedics, traumatology and bone biopsy. Prediction and control of drilling forces and torque are critical to the success of operations involving bone drilling. This paper studied the drilling force, torque and drilling process with automatic and manual drill penetrating into bovine cortical bone. The tests were performed on a drilling system which is used to drill and measure forces and torque during drilling. The effects of drilling speed, feed rate and drill bit diameter on force and torque were discussed separately. The experimental results were proven to be in accordance with the mathematic expressions introduced in this paper. The automatic drilling saved drilling time by 30-60% in the tested range and created less vibration, compared to manual drilling. The deviation between maximum and average force of the automatic drilling was 5N but 25N for manual drilling. To conclude, using the automatic method has significant advantages in control drilling force, torque and drilling process in bone drilling. Copyright © 2013 IPEM. Published by Elsevier Ltd. All rights reserved.

  4. CONTROL ROOM WITH SPRINKLER SYSTEM CONTROLS, INCLUDING MANUAL CONTROL BOXES ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    CONTROL ROOM WITH SPRINKLER SYSTEM CONTROLS, INCLUDING MANUAL CONTROL BOXES FOR THE VENTILATION SYSTEM AND A PLC SWITCH FOR AUTOMATIC CO (CARBON MONOXIDE) SYSTEM. THE AIR TESTING SYSTEM IS FREE STANDING AND THE FANS ARE COMPUTER-OPERATED. - Alaskan Way Viaduct and Battery Street Tunnel, Seattle, King County, WA

  5. FAA Air Traffic Control Operations Concepts. Volume 4. TAAS (Terminal Advanced Automation System) Terminal Controllers

    DTIC Science & Technology

    1988-07-29

    manually under controller comiand. 40.3.7.1.2.1.1.2-19 b. Ordering - In manual ordering , the 780 controller shall have the capability to put o new FOE...7.1.2.1.1.2-09 a. Posting - This orgonization of FOEs shall 780 be provided at the option of the controller. 40.3.7.1.2.1.1.2-19 b. Ordering - In manual ... ordering , the 780 controller shall have the capability to put o new FOE in the appropriate place in a list and to move FOEs with respect to one another

  6. Development of automation software for neutron activation analysis process in Malaysian nuclear agency

    NASA Astrophysics Data System (ADS)

    Yussup, N.; Rahman, N. A. A.; Ibrahim, M. M.; Mokhtar, M.; Salim, N. A. A.; Soh@Shaari, S. C.; Azman, A.

    2017-01-01

    Neutron Activation Analysis (NAA) process has been established in Malaysian Nuclear Agency (Nuclear Malaysia) since 1980s. Most of the procedures established especially from sample registration to sample analysis are performed manually. These manual procedures carried out by the NAA laboratory personnel are time consuming and inefficient. Hence, a software to support the system automation is developed to provide an effective method to replace redundant manual data entries and produce faster sample analysis and calculation process. This paper describes the design and development of automation software for NAA process which consists of three sub-programs. The sub-programs are sample registration, hardware control and data acquisition; and sample analysis. The data flow and connection between the sub-programs will be explained. The software is developed by using National Instrument LabView development package.

  7. Multimodal corridor and capacity analysis manual. Final report

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    NONE

    1998-12-31

    This report presents the results of research carried out under NCHRP Project 8-31, Long-Term Availability of Multimodal Corridor Capacity. The report is presented as a manual on multimodal corridor and capacity analysis. Because transportation-system and corridor capacity for freight and passengers is critical for meeting current and future transportation demand, this manual will provide much needed assistance to a wide range of practitioners, particularly those engaged in performance analysis, capacity management, needs studies, systems planning, and corridor development planning--including major investment studies. It provides information regarding capacity analysis approaches for highways, rail, pipelines, and waterways and presents available options formore » enhancing corridor capacity and performance through various strategies such as new capacity development, freeing up unused capacity, or control of travel demand. Evaluation methods for these options are included.« less

  8. Flight directors for STOl aircraft

    NASA Technical Reports Server (NTRS)

    Rabin, U. H.

    1983-01-01

    Flight director logic for flight path and airspeed control of a powered-lift STOL aircraft in the approach, transition, and landing configurations are developed. The methods for flight director design are investigated. The first method is based on the Optimal Control Model (OCM) of the pilot. The second method, proposed here, uses a fixed dynamic model of the pilot in a state space formulation similar to that of the OCM, and includes a pilot work-load metric. Several design examples are presented with various aircraft, sensor, and control configurations. These examples show the strong impact of throttle effectiveness on the performance and pilot work-load associated with manual control of powered-lift aircraft during approach. Improved performed and reduced pilot work-load can be achieved by using direct-lift-control to increase throttle effectiveness.

  9. Verification of rut depth collected with the INO laser rut measurement system : executive summary report.

    DOT National Transportation Integrated Search

    2011-10-28

    Since 1985, ODOT has been manually collecting rut : depth data using a straight edge and dial gauge (S&G). This : method is slow and dangerous to pavement condition raters : when traffic control is not available. According to the : Pavement Condition...

  10. 40 CFR 60.59b - Reporting and recordkeeping requirements.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... monitor mercury or dioxin/furan instead of conducting performance testing using EPA manual test methods, all integrated 24-hour mercury concentrations or all integrated 2-week dioxin/furan concentrations as... actions taken. (4) For affected facilities that apply activated carbon for mercury or dioxin/furan control...

  11. Neighborhood Team Policing: Prescriptive Package.

    ERIC Educational Resources Information Center

    Bloch, Peter B.; Specht, David

    The manual for neighborhood team policing, a method of decentralizing police departments, presents guidelines for putting a team policing system into effect. Noticeable results of this type of this type organization have been an increased effectiveness in crime control, improved police-community relations, and improved police morale. Chapter 1…

  12. Massage, reflexology and other manual methods for pain management in labour.

    PubMed

    Smith, Caroline A; Levett, Kate M; Collins, Carmel T; Dahlen, Hannah G; Ee, Carolyn C; Suganuma, Machiko

    2018-03-28

    Many women would like to avoid pharmacological or invasive methods of pain management in labour, and this may contribute towards the popularity of complementary methods of pain management. This review examined the evidence currently available on manual methods, including massage and reflexology, for pain management in labour. This review is an update of the review first published in 2012. To assess the effect, safety and acceptability of massage, reflexology and other manual methods to manage pain in labour. For this update, we searched Cochrane Pregnancy and Childbirth's Trials Register (30 June 2017), the Cochrane Central Register of Controlled Trials (CENTRAL; 2017, Issue 6), MEDLINE (1966 to 30 June 2017, CINAHL (1980 to 30 June 2017), the Australian New Zealand Clinical Trials Registry (4 August 2017), Chinese Clinical Trial Registry (4 August 2017), ClinicalTrials.gov, (4 August 2017), the National Center for Complementary and Integrative Health (4 August 2017), the WHO International Clinical Trials Registry Platform (ICTRP) (4 August 2017) and reference lists of retrieved trials. We included randomised controlled trials comparing manual methods with standard care, other non-pharmacological forms of pain management in labour, no treatment or placebo. We searched for trials of the following modalities: massage, warm packs, thermal manual methods, reflexology, chiropractic, osteopathy, musculo-skeletal manipulation, deep tissue massage, neuro-muscular therapy, shiatsu, tuina, trigger point therapy, myotherapy and zero balancing. We excluded trials for pain management relating to hypnosis, aromatherapy, acupuncture and acupressure; these are included in other Cochrane reviews. Two review authors independently assessed trial quality, extracted data and checked data for accuracy. We contacted trial authors for additional information. We assessed the quality of the evidence using the GRADE approach. We included a total of 14 trials; 10 of these (1055 women) contributed data to meta-analysis. Four trials, involving 274 women, met our inclusion criteria but did not contribute data to the review. Over half the trials had a low risk of bias for random sequence generation and attrition bias. The majority of trials had a high risk of performance bias and detection bias, and an unclear risk of reporting bias. We found no trials examining the effectiveness of reflexology.MassageWe found low-quality evidence that massage provided a greater reduction in pain intensity (measured using self-reported pain scales) than usual care during the first stage of labour (standardised mean difference (SMD) -0.81, 95% confidence interval (CI) -1.06 to -0.56, six trials, 362 women). Two trials reported on pain intensity during the second and third stages of labour, and there was evidence of a reduction in pain scores in favour of massage (SMD -0.98, 95% CI -2.23 to 0.26, 124 women; and SMD -1.03, 95% CI -2.17 to 0.11, 122 women). There was very low-quality evidence showing no clear benefit of massage over usual care for the length of labour (in minutes) (mean difference (MD) 20.64, 95% CI -58.24 to 99.52, six trials, 514 women), and pharmacological pain relief (average risk ratio (RR) 0.81, 95% CI 0.37 to 1.74, four trials, 105 women). There was very low-quality evidence showing no clear benefit of massage for assisted vaginal birth (average RR 0.71, 95% CI 0.44 to 1.13, four trials, 368 women) and caesarean section (RR 0.75, 95% CI 0.51 to 1.09, six trials, 514 women). One trial reported less anxiety during the first stage of labour for women receiving massage (MD -16.27, 95% CI -27.03 to -5.51, 60 women). One trial found an increased sense of control from massage (MD 14.05, 95% CI 3.77 to 24.33, 124 women, low-quality evidence). Two trials examining satisfaction with the childbirth experience reported data on different scales; both found more satisfaction with massage, although the evidence was low quality in one study and very low in the other.Warm packsWe found very low-quality evidence for reduced pain (Visual Analogue Scale/VAS) in the first stage of labour (SMD -0.59, 95% CI -1.18 to -0.00, three trials, 191 women), and the second stage of labour (SMD -1.49, 95% CI -2.85 to -0.13, two trials, 128 women). Very low-quality evidence showed reduced length of labour (minutes) in the warm-pack group (MD -66.15, 95% CI -91.83 to -40.47; two trials; 128 women).Thermal manual methodsOne trial evaluated thermal manual methods versus usual care and found very low-quality evidence of reduced pain intensity during the first phase of labour for women receiving thermal methods (MD -1.44, 95% CI -2.24 to -0.65, one trial, 96 women). There was a reduction in the length of labour (minutes) (MD -78.24, 95% CI -118.75 to -37.73, one trial, 96 women, very low-quality evidence). There was no clear difference for assisted vaginal birth (very low-quality evidence). Results were similar for cold packs versus usual care, and intermittent hot and cold packs versus usual care, for pain intensity, length of labour and assisted vaginal birth.Music One trial that compared manual methods with music found very low-quality evidence of reduced pain intensity during labour in the massage group (RR 0.40, 95% CI 0.18 to 0.89, 101 women). There was no evidence of benefit for reduced use of pharmacological pain relief (RR 0.41, 95% CI 0.16 to 1.08, very low-quality evidence).Of the seven outcomes we assessed using GRADE, only pain intensity was reported in all comparisons. Satisfaction with the childbirth experience, sense of control, and caesarean section were rarely reported in any of the comparisons. Massage, warm pack and thermal manual methods may have a role in reducing pain, reducing length of labour and improving women's sense of control and emotional experience of labour, although the quality of evidence varies from low to very low and few trials reported on the key GRADE outcomes. Few trials reported on safety as an outcome. There is a need for further research to address these outcomes and to examine the effectiveness and efficacy of these manual methods for pain management.

  13. Semi-automating the manual literature search for systematic reviews increases efficiency.

    PubMed

    Chapman, Andrea L; Morgan, Laura C; Gartlehner, Gerald

    2010-03-01

    To minimise retrieval bias, manual literature searches are a key part of the search process of any systematic review. Considering the need to have accurate information, valid results of the manual literature search are essential to ensure scientific standards; likewise efficient approaches that minimise the amount of personnel time required to conduct a manual literature search are of great interest. The objective of this project was to determine the validity and efficiency of a new manual search method that utilises the scopus database. We used the traditional manual search approach as the gold standard to determine the validity and efficiency of the proposed scopus method. Outcome measures included completeness of article detection and personnel time involved. Using both methods independently, we compared the results based on accuracy of the results, validity and time spent conducting the search, efficiency. Regarding accuracy, the scopus method identified the same studies as the traditional approach indicating its validity. In terms of efficiency, using scopus led to a time saving of 62.5% compared with the traditional approach (3 h versus 8 h). The scopus method can significantly improve the efficiency of manual searches and thus of systematic reviews.

  14. 46 CFR 62.10-1 - Definitions.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... control means a function of an automatic control system to restrict operation to a specified operating... automatic or manual control. Safety trip control system means a manually or automatically operated system... GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) MARINE ENGINEERING VITAL SYSTEM AUTOMATION Terms Used...

  15. 46 CFR 62.10-1 - Definitions.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... control means a function of an automatic control system to restrict operation to a specified operating... automatic or manual control. Safety trip control system means a manually or automatically operated system... GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) MARINE ENGINEERING VITAL SYSTEM AUTOMATION Terms Used...

  16. 46 CFR 62.10-1 - Definitions.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... control means a function of an automatic control system to restrict operation to a specified operating... automatic or manual control. Safety trip control system means a manually or automatically operated system... GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) MARINE ENGINEERING VITAL SYSTEM AUTOMATION Terms Used...

  17. 46 CFR 62.10-1 - Definitions.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... control means a function of an automatic control system to restrict operation to a specified operating... automatic or manual control. Safety trip control system means a manually or automatically operated system... GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) MARINE ENGINEERING VITAL SYSTEM AUTOMATION Terms Used...

  18. 46 CFR 62.10-1 - Definitions.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... control means a function of an automatic control system to restrict operation to a specified operating... automatic or manual control. Safety trip control system means a manually or automatically operated system... GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) MARINE ENGINEERING VITAL SYSTEM AUTOMATION Terms Used...

  19. [The Confusion Assessment Method: Transcultural adaptation of a French version].

    PubMed

    Antoine, V; Belmin, J; Blain, H; Bonin-Guillaume, S; Goldsmith, L; Guerin, O; Kergoat, M-J; Landais, P; Mahmoudi, R; Morais, J A; Rataboul, P; Saber, A; Sirvain, S; Wolfklein, G; de Wazieres, B

    2018-05-01

    The Confusion Assessment Method (CAM) is a validated key tool in clinical practice and research programs to diagnose delirium and assess its severity. There is no validated French version of the CAM training manual and coding guide (Inouye SK). The aim of this study was to establish a consensual French version of the CAM and its manual. Cross-cultural adaptation to achieve equivalence between the original version and a French adapted version of the CAM manual. A rigorous process was conducted including control of cultural adequacy of the tool's components, double forward and back translations, reconciliation, expert committee review (including bilingual translators with different nationalities, a linguist, highly qualified clinicians, methodologists) and pretesting. A consensual French version of the CAM was achieved. Implementation of the CAM French version in daily clinical practice will enable optimal diagnosis of delirium diagnosis and enhance communication between health professionals in French speaking countries. Validity and psychometric properties are being tested in a French multicenter cohort, opening up new perspectives for improved quality of care and research programs in French speaking countries. Copyright © 2018 Elsevier Masson SAS. All rights reserved.

  20. [The risk of manual handling loads in the hotel sector].

    PubMed

    Muraca, G; Martino, L Barbaro; Abbate, A; De Pasquale, D; Barbuzza, O; Brecciaroli, R

    2007-01-01

    The aim of our study is to evaluate the manual handling risk and the incidence of muscle-skeletal pathologies in the hotel compartment. Our study is conducted on 264 workers of the hotel compartment. The sample is divided on the base of the working turn in the following groups: porter (both to the plans and in the kitchen); waiters to the plans; services (gardeners and workers). The duties have been valued according to the method NIOSH. The presence of muscle-skeletal pathologies has been verified on the base to the accused symptomology, and on the presence of clinical objectivity and to the reports of checks. The data has been compared to a control group. The application of the NIOSH method has showed for each working profile an elevated synthetic index, > 3, and for porter the index is 5. The clinical data has shown an elevated incidence of pathologies of the spine, especially lumbar spine, with a high prevalence in the group of male porters. In conclusion we believe that the manual handling represents a particularly remarkable risk for the workers in the hotel compartment.

  1. Force-reflective teleoperated system with shared and compliant control capabilities

    NASA Technical Reports Server (NTRS)

    Szakaly, Z.; Kim, W. S.; Bejczy, A. K.

    1989-01-01

    The force-reflecting teleoperator breadboard is described. It is the first system among available Research and Development systems with the following combined capabilities: (1) The master input device is not a replica of the slave arm. It is a general purpose device which can be applied to the control of different robot arms through proper mathematical transformations. (2) Force reflection generated in the master hand controller is referenced to forces and moments measured by a six DOF force-moment sensor at the base of the robot hand. (3) The system permits a smooth spectrum of operations between full manual, shared manual and automatic, and full automatic (called traded) control. (4) The system can be operated with variable compliance or stiffness in force-reflecting control. Some of the key points of the system are the data handling and computing architecture, the communication method, and the handling of mathematical transformations. The architecture is a fully synchronized pipeline. The communication method achieves optimal use of a parallel communication channel between the local and remote computing nodes. A time delay box is also implemented in this communication channel permitting experiments with up to 8 sec time delay. The mathematical transformations are computed faster than 1 msec so that control at each node can be operated at 1 kHz servo rate without interpolation. This results in an overall force-reflecting loop rate of 200 Hz.

  2. 14 CFR 33.87 - Endurance test.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... particular engine being tested. (2) Any automatic engine control that is part of the engine must control the engine during the endurance test except for operations where automatic control is normally overridden by manual control or where manual control is otherwise specified for a particular test run. (3) Except as...

  3. 14 CFR 33.87 - Endurance test.

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... particular engine being tested. (2) Any automatic engine control that is part of the engine must control the engine during the endurance test except for operations where automatic control is normally overridden by manual control or where manual control is otherwise specified for a particular test run. (3) Except as...

  4. Twenty-First Annual Conference on Manual Control

    NASA Technical Reports Server (NTRS)

    Miller, R. A. (Compiler); Jagacinski, R. J. (Compiler)

    1986-01-01

    The proceedings of the entitled conference are presented. Twenty-nine manuscripts and eight abstracts pertaining to workload, attention and errors, controller evaluation, movement skills, coordination and decision making, display evaluation and human operator modeling and manual control.

  5. Therapist tips for the brief behavioural activation therapy for depression - revised (BATD-R) treatment manual practical wisdom and clinical nuance

    PubMed Central

    CASSAR, Joanne; ROSS, Joanne; DAHNE, Jennifer; EWER, Philippa; TEESSON, Maree; HOPKO, Derek; LEJUEZ, Carl W.

    2018-01-01

    Objective This article aims to provide supportive guidance for clinicians using the brief behavioral activation treatment for depression - revised (BATD-R) manual. Expanding upon key points less explicitly addressed in the treatment manual, the goal is to convey practical wisdom and clinical nuance beyond that available in the manual, thereby enhancing therapist comfort with the approach and improving treatment delivery. Methods In preparation for a randomised control trial of behavioural activation treatment for depression among substance users (the Activate Study), Professor Carl Lejuez, an author on the manual, provided training to our research team. This occurred over four days in May 2013 at the National Drug and Alcohol Research Centre in Sydney, Australia and involved in-depth discussion about treatment delivery, often addressing important issues implied but not addressed in-depth in the manual. Reflections were discussed throughout training and subsequently collated into key themes. Results Intricacies associated with treatment delivery were identified. Seven key themes emerged, covering: provision of the treatment rationale; therapeutic alliance and self-disclosure; behaviour monitoring; values; angles and steps; contracts; and drawing from other therapeutic approaches. A detailed discussion of how to approach these themes in treatment forms the basis of this article. Conclusions The current article seeks to guide therapists and provide a supplement to the BATD-R manual that will enhance the flexibility and accessibility for therapists utilising this treatment. The suggestions made are useful for straightforward cases of depression and more complicated comorbid presentations, serving as a useful complement for therapists using the manual. PMID:29720886

  6. The Virginia method of determining the cement content of freshly mixed cement-soil mixtures : a manual prepared for the use of the Virginia Dept. of Highways.

    DOT National Transportation Integrated Search

    1971-01-01

    This manual describes a new method developed by the author, based on ASTM Method D2901, for determining the cement content of freshly mixed soil cement. The manual contains information on apparatus, reagents, procedures, source of equipment and reage...

  7. A Manual of Simplified Laboratory Methods for Operators of Wastewater Treatment Facilities.

    ERIC Educational Resources Information Center

    Westerhold, Arnold F., Ed.; Bennett, Ernest C., Ed.

    This manual is designed to provide the small wastewater treatment plant operator, as well as the new or inexperienced operator, with simplified methods for laboratory analysis of water and wastewater. It is emphasized that this manual is not a replacement for standard methods but a guide for plants with insufficient equipment to perform analyses…

  8. METRO-APEX Volume 7.1: Air Pollution Control Officer's Manual. Revised.

    ERIC Educational Resources Information Center

    University of Southern California, Los Angeles. COMEX Research Project.

    The Air Pollution Control Officer's Manual is one of a set of twenty-one manuals used in METRO-APEX 1974, a computerized college and professional level, computer-supported, role-play, simulation exercise of a community with "normal" problems. Stress is placed on environmental quality considerations. APEX 1974 is an expansion of APEX--Air…

  9. Verification of rut depth collected with the INO laser rut measurement system (LRMS) : executive summary report.

    DOT National Transportation Integrated Search

    2011-11-01

    Since 1985, ODOT has been manually collecting rut : depth data using a straight edge and dial gauge (S&G). This : method is slow and dangerous to pavement condition raters : when traffic control is not available. According to the : Pavement Condition...

  10. Asbestos-Containing Materials in School Buildings: A Guidance Document. Part 2.

    ERIC Educational Resources Information Center

    Sawyer, Robert N.; Spooner, Charles M.

    Part 2 of the Environmental Protection Agency (EPA) guidance manuals consists of more detailed information on asbestos identification and control methods. Available information on sprayed asbestos-containing materials in buildings is summarized. Guidelines are presented for the detection and monitoring, removal or encapsulation, and disposal of…

  11. PCBs in Fish: A Problem? Student Guide and Teacher Guide. OEAGLS Investigation 19.

    ERIC Educational Resources Information Center

    Mayer, Victor J.; And Others

    In this secondary school unit, students investigate the health effects and methods for controlling polychlorinated biphenyls (PCBs). The teacher's manual contains a materials list, objectives, teaching strategies, supplementary information on PCBs, and answers to questions included in the accompanying student workbook. Activities presented include…

  12. Corpus-Based Optimization of Language Models Derived from Unification Grammars

    NASA Technical Reports Server (NTRS)

    Rayner, Manny; Hockey, Beth Ann; James, Frankie; Bratt, Harry; Bratt, Elizabeth O.; Gawron, Mark; Goldwater, Sharon; Dowding, John; Bhagat, Amrita

    2000-01-01

    We describe a technique which makes it feasible to improve the performance of a language model derived from a manually constructed unification grammar, using low-quality untranscribed speech data and a minimum of human annotation. The method is on a medium-vocabulary spoken language command and control task.

  13. Calculations of financial incentives for providers in a pay-for-performance program: Manual review versus data from structured fields in electronic health records

    PubMed Central

    Urech, Tracy H.; Woodard, LeChauncy D.; Virani, Salim S.; Dudley, R. Adams; Lutschg, Meghan Z.; Petersen, Laura A.

    2015-01-01

    Background Hospital report cards and financial incentives linked to performance require clinical data that are reliable, appropriate, timely, and cost-effective to process. Pay-for-performance plans are transitioning to automated electronic health record (EHR) data as an efficient method to generate data needed for these programs. Objective To determine how well data from automated processing of structured EHR fields (AP-EHR) reflect data from manual chart review and the impact of these data on performance rewards. Research Design Cross-sectional analysis of performance measures used in a cluster randomized trial assessing the impact of financial incentives on guideline-recommended care for hypertension. Subjects A total of 2,840 patients with hypertension assigned to participating physicians at 12 Veterans Affairs hospital-based outpatient clinics. Fifty-two physicians and 33 primary care personnel received incentive payments. Measures Overall, positive and negative agreement indices and Cohen's kappa were calculated for assessments of guideline-recommended antihypertensive medication use, blood pressure (BP) control, and appropriate response to uncontrolled BP. Pearson's correlation coefficient was used to assess how similar participants’ calculated earnings were between the data sources. Results By manual chart review data, 72.3% of patients were considered to have received guideline-recommended antihypertensive medications compared to 65.0% by AP-EHR review (k=0.51). Manual review indicated 69.5% of patients had controlled BP compared to 66.8% by AP-EHR review (k=0.87). Compared to 52.2% of patients per the manual review, 39.8% received an appropriate response by AP-EHR review (k=0.28). Participants’ incentive payments calculated using the two methods were highly correlated (r≥0.98). Using the AP-EHR data to calculate earnings, participants’ payment changes ranged from a decrease of $91.00 (−30.3%) to an increase of $18.20 (+7.4%) for medication use (IQR, −14.4% to 0%) and a decrease of $100.10 (−31.4%) to an increase of $36.40 (+15.4%) for BP control or appropriate response to uncontrolled BP (IQR, −11.9% to −6.1%). Conclusions Pay-for-performance plans that use only EHR data should carefully consider the measures and the structure of the EHR before data collection and financial incentive disbursement. For this study, we feel that a 10% difference in the total amount of incentive earnings disbursed based on AP-EHR data compared to manual review is acceptable given the time and resources required to abstract data from medical records. PMID:26340661

  14. Speech recognition in advanced rotorcraft - Using speech controls to reduce manual control overload

    NASA Technical Reports Server (NTRS)

    Vidulich, Michael A.; Bortolussi, Michael R.

    1988-01-01

    An experiment has been conducted to ascertain the usefulness of helicopter pilot speech controls and their effect on time-sharing performance, under the impetus of multiple-resource theories of attention which predict that time-sharing should be more efficient with mixed manual and speech controls than with all-manual ones. The test simulation involved an advanced, single-pilot scout/attack helicopter. Performance and subjective workload levels obtained supported the claimed utility of speech recognition-based controls; specifically, time-sharing performance was improved while preparing a data-burst transmission of information during helicopter hover.

  15. Automated search of control points in surface-based morphometry.

    PubMed

    Canna, Antonietta; Russo, Andrea G; Ponticorvo, Sara; Manara, Renzo; Pepino, Alessandro; Sansone, Mario; Di Salle, Francesco; Esposito, Fabrizio

    2018-04-16

    Cortical surface-based morphometry is based on a semi-automated analysis of structural MRI images. In FreeSurfer, a widespread tool for surface-based analyses, a visual check of gray-white matter borders is followed by the manual placement of control points to drive the topological correction (editing) of segmented data. A novel algorithm combining radial sampling and machine learning is presented for the automated control point search (ACPS). Four data sets with 3 T MRI structural images were used for ACPS validation, including raw data acquired twice in 36 healthy subjects and both raw and FreeSurfer preprocessed data of 125 healthy subjects from public databases. The unedited data from a subgroup of subjects were submitted to manual control point search and editing. The ACPS algorithm was trained on manual control points and tested on new (unseen) unedited data. Cortical thickness (CT) and fractal dimensionality (FD) were estimated in three data sets by reconstructing surfaces from both unedited and edited data, and the effects of editing were compared between manual and automated editing and versus no editing. The ACPS-based editing improved the surface reconstructions similarly to manual editing. Compared to no editing, ACPS-based and manual editing significantly reduced CT and FD in consistent regions across different data sets. Despite the extra processing of control point driven reconstructions, CT and FD estimates were highly reproducible in almost all cortical regions, albeit some problematic regions (e.g. entorhinal cortex) may benefit from different editing. The use of control points improves the surface reconstruction and the ACPS algorithm can automate their search reducing the burden of manual editing. Copyright © 2018 Elsevier Inc. All rights reserved.

  16. 21 CFR 892.5650 - Manual radionuclide applicator system.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... system. (a) Identification. A manual radionuclide applicator system is a manually operated device... 21 Food and Drugs 8 2013-04-01 2013-04-01 false Manual radionuclide applicator system. 892.5650... planning computer programs, and accessories. (b) Classification. Class I (general controls). The device is...

  17. 21 CFR 892.5650 - Manual radionuclide applicator system.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... system. (a) Identification. A manual radionuclide applicator system is a manually operated device... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Manual radionuclide applicator system. 892.5650... planning computer programs, and accessories. (b) Classification. Class I (general controls). The device is...

  18. 21 CFR 892.5650 - Manual radionuclide applicator system.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... system. (a) Identification. A manual radionuclide applicator system is a manually operated device... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Manual radionuclide applicator system. 892.5650... planning computer programs, and accessories. (b) Classification. Class I (general controls). The device is...

  19. 21 CFR 892.5650 - Manual radionuclide applicator system.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... system. (a) Identification. A manual radionuclide applicator system is a manually operated device... 21 Food and Drugs 8 2014-04-01 2014-04-01 false Manual radionuclide applicator system. 892.5650... planning computer programs, and accessories. (b) Classification. Class I (general controls). The device is...

  20. 21 CFR 892.5650 - Manual radionuclide applicator system.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... system. (a) Identification. A manual radionuclide applicator system is a manually operated device... 21 Food and Drugs 8 2012-04-01 2012-04-01 false Manual radionuclide applicator system. 892.5650... planning computer programs, and accessories. (b) Classification. Class I (general controls). The device is...

  1. Cognitive Rehabilitation: ACTION Training for Soldiers with Executive Dysfunction

    DTIC Science & Technology

    2015-10-01

    failing to comply with a collection of information if it does not display a currently valid OMB control number. PLEASE DO NOT RETURN YOUR FORM TO... controlled trial. Aim 1: Finalize ACTION curriculum/ manuals; field test Aim 2: Evaluate ACTION instructional methods (the extent to which SM with...metacognitive strategy instruction (MSI), together called Target Acquisition Practices ( Group 1) by evaluating the extent to which training 1) improves

  2. DOD Financial Management: Actions Under Way Need to Be Successfully Completed to Address Long-standing Funds Control Weaknesses

    DTIC Science & Technology

    2014-04-01

    FISCAM Federal Information System Controls Audit Manual FMFIA Federal Managers’ Financial Integrity Act FMR Financial Management Regulation GAAP ...rules are incorporated into generally accepted accounting principles ( GAAP ) for the federal government. For additional information on the two methods of...to hold executive branch officials accountable for proper use of budgetary resources, and to ensure proper stewardship and transparency of the use

  3. Day Care Infection Control Protocol.

    ERIC Educational Resources Information Center

    Seattle-King County Dept. of Public Health, Seattle, WA.

    This day care infection control manual was assembled to provide technical guidance for the prevention and control of communicable diseases to child day care facilities in Seattle and King County, Washington. For each disease, the manual provides background information, public health control recommendations, and letters that can be used to…

  4. Microprocessor-controlled hemodynamics: a step towards improved efficiency and safety.

    PubMed

    Keogh, B E; Jacobs, J; Royston, D; Taylor, K M

    1989-02-01

    Manual titration of sodium nitroprusside (SNP) is widely used for treatment of hypertension following cardiac surgery. This study compared conventional manual control with control by a research prototype of an automatic infusion module based on a proportional plus integral plus derivative (PID) negative feedback loop. Two groups of coronary artery bypass patients requiring SNP for postoperative hypertension were studied prospectively. In the first group, hypertension was controlled by manual adjustment of the SNP infusion rate, and in the second, the infusion rate was controlled automatically. The actual and desired mean arterial pressures (MAP) over consecutive ten-second epochs were recorded during the period of infusion. The MAP was maintained within 10% of the desired MAP 45.8% of the time in the manual group, compared with 90.0% in the automatic group, and the mean percent error in the automatic group was significantly less than in the manual group (P less than 0.01). It is concluded that adoption of such systems will result in improved patient safety and may facilitate more effective distribution of nursing staff within intensive care units.

  5. 76 FR 54156 - National Standards for Traffic Control Devices; the Manual on Uniform Traffic Control Devices for...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-08-31

    ... traffic control device design, location, or operation that have made some existing devices in the field...-2010-0159] RIN 2125-AF43 National Standards for Traffic Control Devices; the Manual on Uniform Traffic Control Devices for Streets and Highways; Revision AGENCY: Federal Highway Administration (FHWA...

  6. 77 FR 28460 - National Standards for Traffic Control Devices; the Manual on Uniform Traffic Control Devices for...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-05-14

    ...-2010-0159] RIN 2125-AF43 National Standards for Traffic Control Devices; the Manual on Uniform Traffic Control Devices for Streets and Highways; Revision AGENCY: Federal Highway Administration (FHWA..., approved by the FHWA, and recognized as the national standard for traffic control devices used on all...

  7. Field Operations and Enforcement Manual for Air Pollution Control. Volume II: Control Technology and General Source Inspection.

    ERIC Educational Resources Information Center

    Weisburd, Melvin I.

    The Field Operations and Enforcement Manual for Air Pollution Control, Volume II, explains in detail the following: technology of source control, modification of operations, particulate control equipment, sulfur dioxide removal systems for power plants, and control equipment for gases and vapors; inspection procedures for general sources, fuel…

  8. Automated and Semiautomated Segmentation of Rectal Tumor Volumes on Diffusion-Weighted MRI: Can It Replace Manual Volumetry?

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Heeswijk, Miriam M. van; Department of Surgery, Maastricht University Medical Centre, Maastricht; Lambregts, Doenja M.J., E-mail: d.lambregts@nki.nl

    Purpose: Diffusion-weighted imaging (DWI) tumor volumetry is promising for rectal cancer response assessment, but an important drawback is that manual per-slice tumor delineation can be highly time consuming. This study investigated whether manual DWI-volumetry can be reproduced using a (semi)automated segmentation approach. Methods and Materials: Seventy-nine patients underwent magnetic resonance imaging (MRI) that included DWI (highest b value [b1000 or b1100]) before and after chemoradiation therapy (CRT). Tumor volumes were assessed on b1000 (or b1100) DWI before and after CRT by means of (1) automated segmentation (by 2 inexperienced readers), (2) semiautomated segmentation (manual adjustment of the volumes obtained bymore » method 1 by 2 radiologists), and (3) manual segmentation (by 2 radiologists); this last assessment served as the reference standard. Intraclass correlation coefficients (ICC) and Dice similarity indices (DSI) were calculated to evaluate agreement between different methods and observers. Measurement times (from a radiologist's perspective) were recorded for each method. Results: Tumor volumes were not significantly different among the 3 methods, either before or after CRT (P=.08 to .92). ICCs compared to manual segmentation were 0.80 to 0.91 and 0.53 to 0.66 before and after CRT, respectively, for the automated segmentation and 0.91 to 0.97 and 0.61 to 0.75, respectively, for the semiautomated method. Interobserver agreement (ICC) pre and post CRT was 0.82 and 0.59 for automated segmentation, 0.91 and 0.73 for semiautomated segmentation, and 0.91 and 0.75 for manual segmentation, respectively. Mean DSI between the automated and semiautomated method were 0.83 and 0.58 pre-CRT and post-CRT, respectively; DSI between the automated and manual segmentation were 0.68 and 0.42 and 0.70 and 0.41 between the semiautomated and manual segmentation, respectively. Median measurement time for the radiologists was 0 seconds (pre- and post-CRT) for the automated method, 41 to 69 seconds (pre-CRT) and 60 to 67 seconds (post-CRT) for the semiautomated method, and 180 to 296 seconds (pre-CRT) and 84 to 91 seconds (post-CRT) for the manual method. Conclusions: DWI volumetry using a semiautomated segmentation approach is promising and a potentially time-saving alternative to manual tumor delineation, particularly for primary tumor volumetry. Once further optimized, it could be a helpful tool for tumor response assessment in rectal cancer.« less

  9. Comparison of characteristics of femtosecond laser-assisted anterior capsulotomy versus manual continuous curvilinear capsulorrhexis: A meta-analysis of 5-year results.

    PubMed

    Ali, Muhammad Hassaan; Ullah, Samee; Javaid, Usman; Javaid, Mamoona; Jamal, Samreen; Butt, Nadeem Hafeez

    2017-10-01

    To perform a meta-analysis on the precision and safety of femtosecond laser-assisted anterior capsulotomy versus conventional manual continuous curvilinear capsulorrhexis. This meta-analysis was conducted from February 2010 to November 2014. Literature search on PubMed, Google Scholar, ExcerptaMedica database and Cochrane Library was done to identify randomised controlled trials and case-control studies. SPSS 20 was used for data analysis. Of the 10 articles included, there were 3(30%) randomised controlled trials and 7(70%) non-randomised controlled trials. The meta-analysis was based on a total of 2,882eyes. Of them, 1,498(51.97%) underwent femtosecond laser-assisted capsulotomy and 1,384(48.02%) underwent manual continuous curvilinear capsulorrhexis. The diameter of the capsulotomy and the rates of anterior capsule tear showed no statistical difference between the femtosecond laser group and the manual capsulorrhexis group (p=0.29 and p=0.68). In terms of circularity of capsulotomy, femtosecond laser group had a more significant advantage than the manual capsulorrhexis group (p<0.001). Femtosecond laser performed capsulotomy with more precision and higher reliability than the manual continuous curvilinear capsulorrhexis.

  10. Freesurfer-initialized large deformation diffeomorphic metric mapping with application to Parkinson's disease

    NASA Astrophysics Data System (ADS)

    Chen, Jingyun; Palmer, Samantha J.; Khan, Ali R.; Mckeown, Martin J.; Beg, Mirza Faial

    2009-02-01

    We apply a recently developed automated brain segmentation method, FS+LDDMM, to brain MRI scans from Parkinson's Disease (PD) subjects, and normal age-matched controls and compare the results to manual segmentation done by trained neuroscientists. The data set consisted of 14 PD subjects and 12 age-matched control subjects without neurologic disease and comparison was done on six subcortical brain structures (left and right caudate, putamen and thalamus). Comparison between automatic and manual segmentation was based on Dice Similarity Coefficient (Overlap Percentage), L1 Error, Symmetrized Hausdorff Distance and Symmetrized Mean Surface Distance. Results suggest that FS+LDDMM is well-suited for subcortical structure segmentation and further shape analysis in Parkinson's Disease. The asymmetry of the Dice Similarity Coefficient over shape change is also discussed based on the observation and measurement of FS+LDDMM segmentation results.

  11. Safe, Effective Use of Pesticides, A Manual for Commercial Applicators: Home, Institutional, and Structural Pest Control.

    ERIC Educational Resources Information Center

    Extension Service (USDA), Washington, DC.

    This manual is designed to assist pest control operators to prepare for certification under the Michigan Pesticide Control Act of 1976. The primary focus of this publication is on home, institutional, and structural pest control. The ten sections included describe: (1) Insect control; (2) Rodent control; (3) Special situation pest control; (4)…

  12. Manual hyperinflation in airway clearance in pediatric patients: a systematic review

    PubMed Central

    de Godoy, Vanessa Cristina Waetge Pires; Zanetti, Nathalia Mendonça; Johnston, Cíntia

    2013-01-01

    Objective To perform an assessment of the available literature on manual hyperinflation as a respiratory physical therapy technique used in pediatric patients, with the main outcome of achieving airway clearance. Methods We reviewed articles included in the Lilacs (Latin American and Caribbean Literature on Health Sciences/Literatura Latino Americana e do Caribe em Ciências da Saúde), Cochrane Library, Medline (via Virtual Health Library and PubMed), SciELO (Scientific Electronic Library), and PEDro (Physiotherapy Evidence Database) databases from 2002 to 2013 using the following search terms: "physiotherapy (techniques)", "respiratory therapy", "intensive care", and "airway clearance". The selected studies were classified according to the level of evidence and grades of recommendation (method of the Oxford Centre for Evidence-Based Medicine) by two examiners, while a third examiner repeated the search and analysis and checked the classification of the articles. Results Three articles were included for analysis, comprising 250 children (aged 0 to 16 years). The main diagnoses were acute respiratory failure, recovery following heart congenital disease and upper abdominal surgery, bone marrow transplantation, asthma, tracheal reconstruction, brain injury, airway injury, and heterogeneous lung diseases. The studies were classified as having a level of evidence 2C and grade of recommendation C. Conclusions Manual hyperinflation appeared useful for airway clearance in the investigated population, although the evidence available in the literature remains insufficient. Therefore, controlled randomized studies are needed to establish the safety and efficacy of manual hyperinflation in pediatric patients. However, manual hyperinflation must be performed by trained physical therapists only. PMID:24213091

  13. 76 FR 69869 - Energy Conservation Program: Test Procedures for Residential Clothes Washers

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-11-09

    ... manual water fill control system, user- adjustable adaptive water fill control system, or adaptive water fill control system with alternate manual water fill control system, use the water fill selector... and transcripts, comments, and other supporting documents/ materials. All documents in the docket are...

  14. Asphalt Raking. Instructor Manual. Trainee Manual.

    ERIC Educational Resources Information Center

    Laborers-AGC Education and Training Fund, Pomfret Center, CT.

    This packet consists of the instructor and trainee manuals for an asphalt raking course. The instructor manual contains a course schedule for 4 days of instruction, content outline, and instructor outline. The trainee manual is divided into five sections: safety, asphalt basics, placing methods, repair and patching, and clean-up and maintenance.…

  15. The effectiveness of manual therapy in treating cervicogenic dizziness: a systematic review.

    PubMed

    Yaseen, Khalid; Hendrick, Paul; Ismail, Ayah; Felemban, Mohannad; Alshehri, Mansour Abdullah

    2018-01-01

    [Purpose] This review provides an evaluation of the evidence for the effectiveness of using manual therapy to treat cervicogenic dizziness. [Subjects and Methods] The literature was systematically searched on the May 2, 2016 using the following online databases: Medline, EMBASE, CINAHL and PEDro. This review included randomised controlled trials and compared the efficacy of manual therapy for the treatment of cervicogenic dizziness, compared to other types of intervention. This study measured changes based on dizziness intensity and frequency. [Results] The primary search found 30 articles, but only four articles met the inclusion criteria. Assessment of methodological quality was performed by two researchers using the PEDro scale. The level of evidence was determined using a recognised grading scale. Three out of the four articles were deemed to have high methodological quality, while the fourth was rated as moderate quality. The attributed level of evidence was moderate (level 2). [Conclusion] Manual therapy is potentially effective for managing cervicogenic dizziness. However, due to the heterogeneity of the results and techniques and the low number of studies, further research is recommended to provide conclusive evidence.

  16. Driving Performance After Self-Regulated Control Transitions in Highly Automated Vehicles.

    PubMed

    Eriksson, Alexander; Stanton, Neville A

    2017-12-01

    This study aims to explore whether driver-paced, noncritical transitions of control may counteract some of the aftereffects observed in the contemporary literature, resulting in higher levels of vehicle control. Research into control transitions in highly automated driving has focused on urgent scenarios where drivers are given a relatively short time span to respond to a request to resume manual control, resulting in seemingly scrambled control when manual control is resumed. Twenty-six drivers drove two scenarios with an automated driving feature activated. Drivers were asked to read a newspaper or monitor the system and relinquish or resume control from the automation when prompted by vehicle systems. Driving performance in terms of lane positioning and steering behavior was assessed for 20 seconds post resuming control to capture the resulting level of control. It was found that lane positioning was virtually unaffected for the duration of the 20-second time span in both automated conditions compared to the manual baseline when drivers resumed manual control; however, significant increases in the standard deviation of steering input were found for both automated conditions compared to baseline. No significant differences were found between the two automated conditions. The results indicate that when drivers self-paced the transfer back to manual control they exhibit less of the detrimental effects observed in system-paced conditions. It was shown that self-paced transitions could reduce the risk of accidents near the edge of the operational design domain. Vehicle manufacturers must consider these benefits when designing contemporary systems.

  17. Skylab Saturn 1B flight manual

    NASA Technical Reports Server (NTRS)

    1972-01-01

    A Saturn 1B Flight Manual provides launch vehicle systems descriptions and predicted performance data for the Skylab missions. Vehicle SL-2 (SA-206) is the baseline for this manual; but, as a result of the great similarity, the material is representative of SL-3 and SL-4 launch vehicles, also. The Flight Manual is not a control document but is intended primarily as an aid to astronauts who are training for Skylab missions. In order to provide a comprehensive reference for that purpose, the manual also contains descriptions of the ground support interfaces, prelaunch operations, and emergency procedures. Mission variables and constraints are summarized, and mission control monitoring and data flow during launch preparation and flight are discussed.

  18. Assessment of ICount software, a precise and fast egg counting tool for the mosquito vector Aedes aegypti.

    PubMed

    Gaburro, Julie; Duchemin, Jean-Bernard; Paradkar, Prasad N; Nahavandi, Saeid; Bhatti, Asim

    2016-11-18

    Widespread in the tropics, the mosquito Aedes aegypti is an important vector of many viruses, posing a significant threat to human health. Vector monitoring often requires fecundity estimation by counting eggs laid by female mosquitoes. Traditionally, manual data analyses have been used but this requires a lot of effort and is the methods are prone to errors. An easy tool to assess the number of eggs laid would facilitate experimentation and vector control operations. This study introduces a built-in software called ICount allowing automatic egg counting of the mosquito vector, Aedes aegypti. ICount egg estimation compared to manual counting is statistically equivalent, making the software effective for automatic and semi-automatic data analysis. This technique also allows rapid analysis compared to manual methods. Finally, the software has been used to assess p-cresol oviposition choices under laboratory conditions in order to test the system with different egg densities. ICount is a powerful tool for fast and precise egg count analysis, freeing experimenters from manual data processing. Software access is free and its user-friendly interface allows easy use by non-experts. Its efficiency has been tested in our laboratory with oviposition dual choices of Aedes aegypti females. The next step will be the development of a mobile application, based on the ICount platform, for vector monitoring surveys in the field.

  19. Interagency field manual for the collection of water-quality data

    USGS Publications Warehouse

    Lurry, Dee L.; Kolbe, Christine M.

    2000-01-01

    The USEPA, IBWC, USGS, and Texas Natural Resource Conservation Commission (TNRCC) have been working cooperatively to establish a Water-Quality Monitoring Council for the international reach of the Rio Grande (Río Bravo). A similar effort is occurring along the western international boundary with interested partners including the U.S. Bureau of Reclamation (BOR), Arizona Department of Environmental Quality (ADEQ), and the California Regional Water Quality Control Board (CRWQCB). As of February 1997, the partners agreed to work towards greater cooperation, specifically: 1. to revise the 1977 Joint Report of IBWC Engineers as specified in IBWC Minute No. 289; 2. to implement a binational Intergovernmental Task Force for Water-Quality Monitoring (ITFM) workgroup by inviting the participation of cooperators from Mexico; 3. to review and revise each agency’s existing monitoring network to reduce interagency redundancy; 4. to develop a bilingual manual for water-quality monitoring that would describe various field methods used for sampling water, aquatic biology, and sediment, and for assessing stream habitat; and selection of methods on the basis of DQOs, representativeness, and limitations; 5. to establish a common, easily accessible water-quality database; and 6. to hold joint training programs in water-quality monitoring and data management. Part of the fourth goal—to develop a field manual for water-sample-collection methods—will be accomplished with the publication of this manual.

  20. Comparison of the Automated cobas u 701 Urine Microscopy and UF-1000i Flow Cytometry Systems and Manual Microscopy in the Examination of Urine Sediments.

    PubMed

    Lee, Wonmok; Ha, Jung-Sook; Ryoo, Nam-Hee

    2016-09-01

    The cobas u 701, a new automated image-based urine sediment analyzer, was introduced recently. In this study, we compared its performance with that of UF-1000i flow cytometry and manual microscopy in the examination of urine sediments. Precision, linearity, and carry-over were determined for the two urine sediment analyzers. For a comparison of the method, 300 urine samples were examined by the automated analyzers and by manual microscopy using a KOVA chamber. Within-run coefficients of variation (CVs) for the control materials were 7.0-8.8% and 1.7-5.7% for the cobas u 701 and UF-1000i systems, respectively. Between-run CVs were 8.5-9.8% and 2.7-5.4%, respectively. Both instruments showed good linearity and negligible carry-over. For red blood cells (RBC), white blood cells (WBC), and epithelial cells (EPI), the overall concordance rates within one grade of difference among the three methods were good (78.6-86.0%, 88.7-93.8%, and 81.3-90.7%, respectively). The concordance rate for casts was poor (66.5-68.9%). Compared with manual microscopy, the two automated sediment analyzers tested in this study showed satisfactory analytical performances for RBC, WBC, and EPI. However, for other urine sediment particles confirmation by visual microscopy is still required. © 2016 Wiley Periodicals, Inc.

  1. 46 CFR 161.002-12 - Manual fire alarm systems.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... the control unit and terminating at manual fire alarm boxes. Power failure alarm devices may be... specifically approved. (b) Types. Manual fire alarm systems shall be one of the following types, or a... using manually operated fire alarm boxes. (3) Other types as may be developed. (c) Power supply. The...

  2. 46 CFR 161.002-12 - Manual fire alarm systems.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... the control unit and terminating at manual fire alarm boxes. Power failure alarm devices may be... specifically approved. (b) Types. Manual fire alarm systems shall be one of the following types, or a... using manually operated fire alarm boxes. (3) Other types as may be developed. (c) Power supply. The...

  3. 46 CFR 161.002-12 - Manual fire alarm systems.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... the control unit and terminating at manual fire alarm boxes. Power failure alarm devices may be... specifically approved. (b) Types. Manual fire alarm systems shall be one of the following types, or a... using manually operated fire alarm boxes. (3) Other types as may be developed. (c) Power supply. The...

  4. 49 CFR 236.1039 - Operations and Maintenance Manual.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 49 Transportation 4 2010-10-01 2010-10-01 false Operations and Maintenance Manual. 236.1039... Train Control Systems § 236.1039 Operations and Maintenance Manual. (a) The railroad shall catalog and..., modification, inspection, and testing of the PTC system and have them in one Operations and Maintenance Manual...

  5. 40 CFR Table A-1 to Subpart A of... - Summary of Applicable Requirements for Reference and Equivalent Methods for Air Monitoring of...

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... Methods for Air Monitoring of Criteria Pollutants Pollutant Ref. or equivalent Manual or automated Applicable part 50 appendix Applicable subparts of part 53 A B C D E F SO2 Reference Manual A Equivalent Manual ✓ ✓ Automated ✓ ✓ ✓ CO Reference Automated C ✓ ✓ Equivalent Manual ✓ ✓ Automated ✓ ✓ ✓ O3...

  6. A Manual on Nonviolence and Children.

    ERIC Educational Resources Information Center

    Judson, Stephanie, Comp.

    This manual on teaching children non-violent attitudes and the skills for non-violent conflict resolution suggests teaching activities and methods, describes classrooms in which these methods have been employed, and explains the underlying theory of conflict resolution. The first part of the manual, an outgrowth of the Friends' Nonviolence and…

  7. ANIE: A mathematical algorithm for automated indexing of planar deformation features in quartz grains

    NASA Astrophysics Data System (ADS)

    Huber, Matthew S.; Ferriãre, Ludovic; Losiak, Anna; Koeberl, Christian

    2011-09-01

    Abstract- Planar deformation features (PDFs) in quartz, one of the most commonly used diagnostic indicators of shock metamorphism, are planes of amorphous material that follow crystallographic orientations, and can thus be distinguished from non-shock-induced fractures in quartz. The process of indexing data for PDFs from universal-stage measurements has traditionally been performed using a manual graphical method, a time-consuming process in which errors can easily be introduced. A mathematical method and computer algorithm, which we call the Automated Numerical Index Executor (ANIE) program for indexing PDFs, was produced, and is presented here. The ANIE program is more accurate and faster than the manual graphical determination of Miller-Bravais indices, as it allows control of the exact error used in the calculation and removal of human error from the process.

  8. Comparison of pressure-controlled provocation discography using automated versus manual syringe pump manometry in patients with chronic low back pain.

    PubMed

    Derby, Richard; Lee, Sang Hoon; Lee, Jeong-Eun; Lee, Sang-Heon

    2011-01-01

    The study compares the rate of positive discograms using an automated versus a manual pressure-controlled injection devise and compares the pressure and volume values at various pressures and initial evoked pain and 6/10 or greater evoked pain. A retrospective study prospectively collected patient study data used in a prior prospective study and with prospectively collected data which is routinely collected per our institutional standardized audit protocol. Two custom-built disc manometers (automated injection speed control; manual injection speed control) were sequentially employed during provocation discography in 510 discs of 151 consecutive patients. Two hundred thirty-seven discs of 67 patients with chronic low back pain were evaluated using the automated manometer (automated group) and 273 discs of 84 patients were evaluated with a manual manometer (manual group). No significant differences in positive discogram rates were found between the automated and manual groups (32.1% vs 32.6% per disc, respectively, P>0.05). No significant differences in low-pressure positive discogram rates were found (16.0% vs 15.0% per disc, automated group versus manual group, respectively, P>0.05). However, there were significantly increased volumes and lower pressures at initial and "bad" pain provocation. The study results found equivalent positive discogram rates following a series of pressure-controlled discography using either an automated or manual pressure devise. There were, however significant increases in volume at both initial onset of evoked pain and at 6/10 pain when using the automated injection devise that may have caused the observed lower opening pressure and lower pressure values at initial evoked pain. Assuming increased volumes are innocuous, automated injection is inherently more controlled and may better reduce unintended and often unrecorded spurious high dynamic pressure peaks thereby reducing conscious and unconscious operator bias. Wiley Periodicals, Inc.

  9. Automated and Semiautomated Segmentation of Rectal Tumor Volumes on Diffusion-Weighted MRI: Can It Replace Manual Volumetry?

    PubMed

    van Heeswijk, Miriam M; Lambregts, Doenja M J; van Griethuysen, Joost J M; Oei, Stanley; Rao, Sheng-Xiang; de Graaff, Carla A M; Vliegen, Roy F A; Beets, Geerard L; Papanikolaou, Nikos; Beets-Tan, Regina G H

    2016-03-15

    Diffusion-weighted imaging (DWI) tumor volumetry is promising for rectal cancer response assessment, but an important drawback is that manual per-slice tumor delineation can be highly time consuming. This study investigated whether manual DWI-volumetry can be reproduced using a (semi)automated segmentation approach. Seventy-nine patients underwent magnetic resonance imaging (MRI) that included DWI (highest b value [b1000 or b1100]) before and after chemoradiation therapy (CRT). Tumor volumes were assessed on b1000 (or b1100) DWI before and after CRT by means of (1) automated segmentation (by 2 inexperienced readers), (2) semiautomated segmentation (manual adjustment of the volumes obtained by method 1 by 2 radiologists), and (3) manual segmentation (by 2 radiologists); this last assessment served as the reference standard. Intraclass correlation coefficients (ICC) and Dice similarity indices (DSI) were calculated to evaluate agreement between different methods and observers. Measurement times (from a radiologist's perspective) were recorded for each method. Tumor volumes were not significantly different among the 3 methods, either before or after CRT (P=.08 to .92). ICCs compared to manual segmentation were 0.80 to 0.91 and 0.53 to 0.66 before and after CRT, respectively, for the automated segmentation and 0.91 to 0.97 and 0.61 to 0.75, respectively, for the semiautomated method. Interobserver agreement (ICC) pre and post CRT was 0.82 and 0.59 for automated segmentation, 0.91 and 0.73 for semiautomated segmentation, and 0.91 and 0.75 for manual segmentation, respectively. Mean DSI between the automated and semiautomated method were 0.83 and 0.58 pre-CRT and post-CRT, respectively; DSI between the automated and manual segmentation were 0.68 and 0.42 and 0.70 and 0.41 between the semiautomated and manual segmentation, respectively. Median measurement time for the radiologists was 0 seconds (pre- and post-CRT) for the automated method, 41 to 69 seconds (pre-CRT) and 60 to 67 seconds (post-CRT) for the semiautomated method, and 180 to 296 seconds (pre-CRT) and 84 to 91 seconds (post-CRT) for the manual method. DWI volumetry using a semiautomated segmentation approach is promising and a potentially time-saving alternative to manual tumor delineation, particularly for primary tumor volumetry. Once further optimized, it could be a helpful tool for tumor response assessment in rectal cancer. Copyright © 2016 Elsevier Inc. All rights reserved.

  10. Manual Therapy, Therapeutic Patient Education, and Therapeutic Exercise, an Effective Multimodal Treatment of Nonspecific Chronic Neck Pain: A Randomized Controlled Trial.

    PubMed

    Beltran-Alacreu, Hector; López-de-Uralde-Villanueva, Ibai; Fernández-Carnero, Josué; La Touche, Roy

    2015-10-01

    The aim of this study was to determine the effectiveness of a multimodal treatment in the short and medium term for disability in nonspecific chronic neck pain. The design of this study is a single-blinded randomized controlled trial carried out in a university research laboratory. Forty-five patients between 18 and 65 yrs with nonspecific chronic neck pain were included in this study. Each patient was treated eight times over a 4-wk period. The sample was divided into three groups: control group, subjected to a protocol of manual therapy; experimental group 1, subjected to a protocol of manual therapy and therapeutic patient education; and experimental group 2, subjected to manual therapy, therapeutic patient education, and a therapeutic exercise protocol. Assessments were performed at baseline and at 4, 8, and 16 wks using the following measurements: the Neck Disability Index, the 11-item Tampa Scale of Kinesiophobia, the Fear Avoidance Beliefs Questionnaire, the Neck Flexor Muscle Endurance Test, and the Visual Analog Fatigue Scale. The nonparametric Kruskal-Wallis test for the Neck Disability Index showed statistically significant differences between baseline outcomes and all follow-up periods (P < 0.01). In the Kruskal-Wallis test, differences were found for the Visual Analog Fatigue Scale and the Neck Flexor Muscle Endurance Test in the follow-ups at 8 and 16 wks (P < 0.05). Analysis of variance for group × time interaction showed statistically significant changes (Tampa Scale of Kinesiophobia, F = 3.613, P = 0.005; Fear Avoidance Beliefs Questionnaire, F = 2.803, P = 0.022). Minimal detectable changes were obtained in both experimental groups for the 11-item Tampa Scale of Kinesiophobia but not in the control group. Differences between experimental groups and the control group were found in the short and medium term. A multimodal treatment is a good method for reducing disability in patients with nonspecific chronic neck pain in the short and medium term.

  11. Oral Rehydration Therapy and the Control of Diarrheal Diseases. Training for Development. Peace Corps Information Collection & Exchange Training Manual No. T-34.

    ERIC Educational Resources Information Center

    Clark, Mari; And Others

    This manual was developed to train Peace Corps volunteers and other community health workers in oral rehydration therapy (ORT) and the control of diarrheal diseases. Using a competency-based format, the manual contains six training modules (organized in 22 sessions) that focus on interrelated health education and technical content areas. Each…

  12. Contour propagation for lung tumor delineation in 4D-CT using tensor-product surface of uniform and non-uniform closed cubic B-splines

    NASA Astrophysics Data System (ADS)

    Jin, Renchao; Liu, Yongchuan; Chen, Mi; Zhang, Sheng; Song, Enmin

    2018-01-01

    A robust contour propagation method is proposed to help physicians delineate lung tumors on all phase images of four-dimensional computed tomography (4D-CT) by only manually delineating the contours on a reference phase. The proposed method models the trajectory surface swept by a contour in a respiratory cycle as a tensor-product surface of two closed cubic B-spline curves: a non-uniform B-spline curve which models the contour and a uniform B-spline curve which models the trajectory of a point on the contour. The surface is treated as a deformable entity, and is optimized from an initial surface by moving its control vertices such that the sum of the intensity similarities between the sampling points on the manually delineated contour and their corresponding ones on different phases is maximized. The initial surface is constructed by fitting the manually delineated contour on the reference phase with a closed B-spline curve. In this way, the proposed method can focus the registration on the contour instead of the entire image to prevent the deformation of the contour from being smoothed by its surrounding tissues, and greatly reduce the time consumption while keeping the accuracy of the contour propagation as well as the temporal consistency of the estimated respiratory motions across all phases in 4D-CT. Eighteen 4D-CT cases with 235 gross tumor volume (GTV) contours on the maximal inhale phase and 209 GTV contours on the maximal exhale phase are manually delineated slice by slice. The maximal inhale phase is used as the reference phase, which provides the initial contours. On the maximal exhale phase, the Jaccard similarity coefficient between the propagated GTV and the manually delineated GTV is 0.881 +/- 0.026, and the Hausdorff distance is 3.07 +/- 1.08 mm. The time for propagating the GTV to all phases is 5.55 +/- 6.21 min. The results are better than those of the fast adaptive stochastic gradient descent B-spline method, the 3D  +  t B-spline method and the diffeomorphic demons method. The proposed method is useful for helping physicians delineate target volumes efficiently and accurately.

  13. A New Design Method of Automotive Electronic Real-time Control System

    NASA Astrophysics Data System (ADS)

    Zuo, Wenying; Li, Yinguo; Wang, Fengjuan; Hou, Xiaobo

    Structure and functionality of automotive electronic control system is becoming more and more complex. The traditional manual programming development mode to realize automotive electronic control system can't satisfy development needs. So, in order to meet diversity and speedability of development of real-time control system, combining model-based design approach and auto code generation technology, this paper proposed a new design method of automotive electronic control system based on Simulink/RTW. Fristly, design algorithms and build a control system model in Matlab/Simulink. Then generate embedded code automatically by RTW and achieve automotive real-time control system development in OSEK/VDX operating system environment. The new development mode can significantly shorten the development cycle of automotive electronic control system, improve program's portability, reusability and scalability and had certain practical value for the development of real-time control system.

  14. The impact of injector-based contrast agent administration in time-resolved MRA.

    PubMed

    Budjan, Johannes; Attenberger, Ulrike I; Schoenberg, Stefan O; Pietsch, Hubertus; Jost, Gregor

    2018-05-01

    Time-resolved contrast-enhanced MR angiography (4D-MRA), which allows the simultaneous visualization of the vasculature and blood-flow dynamics, is widely used in clinical routine. In this study, the impact of two different contrast agent injection methods on 4D-MRA was examined in a controlled, standardized setting in an animal model. Six anesthetized Goettingen minipigs underwent two identical 4D-MRA examinations at 1.5 T in a single session. The contrast agent (0.1 mmol/kg body weight gadobutrol, followed by 20 ml saline) was injected using either manual injection or an automated injection system. A quantitative comparison of vascular signal enhancement and quantitative renal perfusion analyses were performed. Analysis of signal enhancement revealed higher peak enhancements and shorter time to peak intervals for the automated injection. Significantly different bolus shapes were found: automated injection resulted in a compact first-pass bolus shape clearly separated from the recirculation while manual injection resulted in a disrupted first-pass bolus with two peaks. In the quantitative perfusion analyses, statistically significant differences in plasma flow values were found between the injection methods. The results of both qualitative and quantitative 4D-MRA depend on the contrast agent injection method, with automated injection providing more defined bolus shapes and more standardized examination protocols. • Automated and manual contrast agent injection result in different bolus shapes in 4D-MRA. • Manual injection results in an undefined and interrupted bolus with two peaks. • Automated injection provides more defined bolus shapes. • Automated injection can lead to more standardized examination protocols.

  15. Measurement of atmospheric mercury species with manual sampling and analysis methods in a case study in Indiana

    USGS Publications Warehouse

    Risch, M.R.; Prestbo, E.M.; Hawkins, L.

    2007-01-01

    Ground-level concentrations of three atmospheric mercury species were measured using manual sampling and analysis to provide data for estimates of mercury dry deposition. Three monitoring stations were operated simultaneously during winter, spring, and summer 2004, adjacent to three mercury wet-deposition monitoring stations in northern, central, and southern Indiana. The monitoring locations differed in land-use setting and annual mercury-emissions level from nearby sources. A timer-controlled air-sampling system that contained a three-part sampling train was used to isolate reactive gaseous mercury, particulate-bound mercury, and elemental mercury. The sampling trains were exchanged every 6 days, and the mercury species were quantified in a laboratory. A quality-assurance study indicated the sampling trains could be held at least 120 h without a significant change in reactive gaseous or particulate-bound mercury concentrations. The manual sampling method was able to provide valid mercury concentrations in 90 to 95% of samples. Statistical differences in mercury concentrations were observed during the project. Concentrations of reactive gaseous and elemental mercury were higher in the daytime samples than in the nighttime samples. Concentrations of reactive gaseous mercury were higher in winter than in summer and were highest at the urban monitoring location. The results of this case study indicated manual sampling and analysis could be a reliable method for measurement of atmospheric mercury species and has the capability for supplying representative concentrations in an effective manner from a long-term deposition-monitoring network. ?? 2007 Springer Science+Business Media B.V.

  16. Internal and external cooling methods and their effect on body temperature, thermal perception and dexterity.

    PubMed

    Maley, Matthew J; Minett, Geoffrey M; Bach, Aaron J E; Zietek, Stephanie A; Stewart, Kelly L; Stewart, Ian B

    2018-01-01

    The present study aimed to compare a range of cooling methods possibly utilised by occupational workers, focusing on their effect on body temperature, perception and manual dexterity. Ten male participants completed eight trials involving 30 min of seated rest followed by 30 min of cooling or control of no cooling (CON) (34°C, 58% relative humidity). The cooling methods utilised were: ice cooling vest (CV0), phase change cooling vest melting at 14°C (CV14), evaporative cooling vest (CVEV), arm immersion in 10°C water (AI), portable water-perfused suit (WPS), heliox inhalation (HE) and ice slushy ingestion (SL). Immediately before and after cooling, participants were assessed for fine (Purdue pegboard task) and gross (grip and pinch strength) manual dexterity. Rectal and skin temperature, as well as thermal sensation and comfort, were monitored throughout. Compared with CON, SL was the only method to reduce rectal temperature (P = 0.012). All externally applied cooling methods reduced skin temperature (P<0.05), though CV0 resulted in the lowest skin temperature versus other cooling methods. Participants felt cooler with CV0, CV14, WPS, AI and SL (P<0.05). AI significantly impaired Purdue pegboard performance (P = 0.001), but did not affect grip or pinch strength (P>0.05). The present study observed that ice ingestion or ice applied to the skin produced the greatest effect on rectal and skin temperature, respectively. AI should not be utilised if workers require subsequent fine manual dexterity. These results will help inform future studies investigating appropriate pre-cooling methods for the occupational worker.

  17. Manual-control Analysis Applied to the Money-supply Control Task

    NASA Technical Reports Server (NTRS)

    Wingrove, R. C.

    1984-01-01

    The recent procedure implemented by the Federal Reserve Board to control the money supply is formulated in the form of a tracking model as used in the study of manual-control tasks. Using this model, an analysis is made to determine the effect of monetary control on the fluctuations in economic output. The results indicate that monetary control can reduce the amplitude of fluctuations at frequencies near the region of historic business cycles. However, with significant time lags in the control loop, monetary control tends to increase the amplitude of the fluctuations at the higher frequencies. How the investigator or student can use the tools developed in the field of manual-control analysis to study the nature of economic fluctuations and to examine different strategies for stabilization is examined.

  18. Turtle Manual.

    ERIC Educational Resources Information Center

    Schneider, Marlene; Robin, Arthur

    This manual describes the Turtle Technique which was developed to help children with behavior problems control their own disruptive behavior. The technique differs from other behavior modification techniques in that it is based upon self-control rather than external control of disruptive behavior. The Turtle Technique first teaches the child how…

  19. Aquatic Pest Control. Manual 99.

    ERIC Educational Resources Information Center

    Missouri Univ., Columbia. Agricultural Experiment Station.

    This training manual provides information needed to meet the minimum EPA standards for certification as a commercial applicator of pesticides in the aquatic pest control category. The text discusses various water use situations; aquatic weed identification; herbicide use and effects; and aquatic insects and their control. (CS)

  20. What is industrial hygiene? | News

    Science.gov Websites

    Radiological Control Manual (FRCM) Graphic design standards Quality Assurance Manual (QAM) Forms Forms , 2016 | Rob Bushek icon icon icon Industrial hygiene is concerned primarily with the control of that science and art devoted to the anticipation, recognition, evaluation and control of those

  1. 77 FR 18283 - Self-Regulatory Organizations; The National Securities Clearing Corporation; Notice of Filing and...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-03-27

    .... NSCC believes it can offer a number of control improvements to the current manual, decentralized, and...: Electronic Comments Use the Commission's Internet comment form ( http://www.sec.gov/rules/sro.shtml ); or... one method. The Commission will post all comments on the Commission's Internet Web site ( http://www...

  2. Agricultural Animal Pest Control. Bulletin 767.

    ERIC Educational Resources Information Center

    Nolan, Maxcy P., Jr.

    Included in this training manual are descriptions and pictures of the following agricultural animal pests: mosquitoes, stable flies, horse flies and deer or yellow flies, house flies, horn flies, wound-infesting larvae, lice, mites, ticks, and bots and grubs. Information is given on the life-cycle and breeding habits of the pests. Methods of…

  3. Ultrasonic Testing, Aviation Quality Control (Advanced): 9227.03.

    ERIC Educational Resources Information Center

    Dade County Public Schools, Miami, FL.

    This unit of instruction covers the theory of ultrasonic sound, methods of applying soundwaves to test specimens and interpreting results, calibrating the ultrasonic equipment, and the use of standards. Study periods, group discussions, and extensive use of textbooks and training manuals are to be used. These are listed along with references and…

  4. Guidance Document on Anaerobic Digester Foaming Prevention and Control Methods (WERF Report INFR1SG10a)

    EPA Science Inventory

    The development of this anaerobic digester (AD) foaming guidance document is based on the need for a specific detailed methodology that water resource recovery facilities (WRRF) personnel can follow and implement to manage or mitigate AD foam incidents. This guidance manual is th...

  5. Methods of rapid, early selection of poplar clones for maximum yield potential: a manual of procedures.

    Treesearch

    USDA FS

    1982-01-01

    Instructions, illustrated with examples and experimental results, are given for the controlled-environment propagation and selection of poplar clones. Greenhouse and growth-room culture of poplar stock plants and scions are described, and statistical techniques for discriminating among clones on the basis of growth variables are emphasized.

  6. Group Therapy for Anxiety in Children with Autism Spectrum Disorder

    ERIC Educational Resources Information Center

    McConachie, Helen; McLaughlin, Eleanor; Grahame, Victoria; Taylor, Helen; Honey, Emma; Tavernor, Laura; Rodgers, Jacqui; Freeston, Mark; Hemm, Cahley; Steen, Nick; Le Couteur, Ann

    2014-01-01

    Aim: To investigate the acceptability and feasibility of adapted group therapy for anxiety in children with autism spectrum disorder in a pilot randomised controlled trial. Method: A total of 32 children aged 9-13 years were randomised to immediate or delayed therapy using the "Exploring Feelings" manual (Attwood, 2004). Child and parent…

  7. Comparison of Manual Refraction Versus Autorefraction in 60 Diabetic Retinopathy Patients

    PubMed Central

    Shirzadi, Keyvan; Shahraki, Kourosh; Yahaghi, Emad; Makateb, Ali; Khosravifard, Keivan

    2016-01-01

    Aim: The purpose of the study was to evaluate the comparison of manual refraction versus autorefraction in diabetic retinopathy patients. Material and Methods: The study was conducted at the Be’sat Army Hospital from 2013-2015. In the present study differences between two common refractometry methods (manual refractometry and Auto refractometry) in diagnosis and follow up of retinopathy in patients affected with diabetes is investigated. Results: Our results showed that there is a significant difference in visual acuity score of patients between manual and auto refractometry. Despite this fact, spherical equivalent scores of two methods of refractometry did not show a significant statistical difference in the patients. Conclusion: Although use of manual refraction is comparable with autorefraction in evaluating spherical equivalent scores in diabetic patients affected with retinopathy, but in the case of visual acuity results from these two methods are not comparable. PMID:27703289

  8. Cross-cultural adaptation of the Window to Hope: a psychological intervention to reduce hopelessness among U.S. veterans with traumatic brain injury.

    PubMed

    Matarazzo, Bridget B; Hoffberg, Adam S; Clemans, Tracy A; Signoracci, Gina M; Simpson, Grahame K; Brenner, Lisa A

    2014-01-01

    To conduct a cross-cultural adaptation of Window to Hope (WtoH), a treatment to reduce hopelessness after traumatic brain injury (TBI), from the Australian civilian context to that of U.S. Veterans. Three-stage mixed-methods approach. Stage 1: Consensus conference with stakeholders to revise the manual. Stage 2: Pilot study of the revised manual with US Veterans to examine acceptability, feasibility and fidelity. Stage 3: Review of results with consensus conference attendees and further revisions. Stage 1: Conference attendees reached 100% consensus regarding changes made to the manual. Stage 2: Qualitative results yielded themes that suggest that participants benefitted from the intervention and that multiple factors contributed to successful implementation (Narrative Evaluation of Intervention Interview, User Feedback Survey-Modified, Post-Treatment Interviews). Therapists achieved 100% treatment fidelity. Quantitative results from the Client Satisfaction Questionnaire-8 suggest that the intervention was acceptable. Stage 3: The culturally adapted manual was finalized. RESULTS of this study suggest that the revised WtoH manual is acceptable and feasible. US therapists exhibited adherence to the protocol. The three-stage methodology was successfully employed to cross-culturally adapt an intervention that is well-suited for a Phase II randomized controlled trial among US military Veterans.

  9. Comparison of the cleaning capacity of Mtwo and Pro Taper rotary systems and manual instruments in primary teeth

    PubMed Central

    Azar, Mohammad Reza; Safi, Laya; Nikaein, Afshin

    2012-01-01

    Background: Root canal cleaning is an important step in endodontic therapy. In order to develop better techniques, a new generation of endodontic instruments has been designed. The aim of this study was to compare the effectiveness of manual K-files (Mani Co, Tokyo, Japan) and two rotary systems–Mtwo (Dentsply-Maillefer, Ballaigues, Switzerland) and ProTaper (VDW, Munich, Germany)–for root canal preparation in primary molars. Materials and Methods: India ink was injected to 160 mesiobuccal and distal root canals of mandibular primary molars. The teeth were randomly divided into three experimental groups and one control group. In each experimental group, either manual instruments (K-files) or rotary instruments (Mtwo or ProTaper) were used to prepare root canals. After cleaning the canals and clearing the teeth, ink removal was evaluated with a stereomicroscope. Statistical analysis was done with Kruskal–Wallis and Friedman tests. Results: There were no significant differences in cleaning efficiency between manual and rotary instruments. Only ProTaper files performed significantly better in the coronal and middle thirds than in the apical third of the root canal. Conclusion: Manual K-files and the Mtwo and ProTaper rotary systems showed equally acceptable cleaning ability in primary molar root canals. PMID:22623929

  10. An automated workflow for patient-specific quality control of contour propagation

    NASA Astrophysics Data System (ADS)

    Beasley, William J.; McWilliam, Alan; Slevin, Nicholas J.; Mackay, Ranald I.; van Herk, Marcel

    2016-12-01

    Contour propagation is an essential component of adaptive radiotherapy, but current contour propagation algorithms are not yet sufficiently accurate to be used without manual supervision. Manual review of propagated contours is time-consuming, making routine implementation of real-time adaptive radiotherapy unrealistic. Automated methods of monitoring the performance of contour propagation algorithms are therefore required. We have developed an automated workflow for patient-specific quality control of contour propagation and validated it on a cohort of head and neck patients, on which parotids were outlined by two observers. Two types of error were simulated—mislabelling of contours and introducing noise in the scans before propagation. The ability of the workflow to correctly predict the occurrence of errors was tested, taking both sets of observer contours as ground truth, using receiver operator characteristic analysis. The area under the curve was 0.90 and 0.85 for the observers, indicating good ability to predict the occurrence of errors. This tool could potentially be used to identify propagated contours that are likely to be incorrect, acting as a flag for manual review of these contours. This would make contour propagation more efficient, facilitating the routine implementation of adaptive radiotherapy.

  11. Process Control Manual for Aerobic Biological Wastewater Treatment Facilities.

    ERIC Educational Resources Information Center

    Environmental Protection Agency, Washington, DC. Office of Water Programs.

    This Environmental Protection Agency (EPA) publication is an operations manual for activated sludge and trickling filter wastewater treatment facilities. The stated purpose of the manual is to provide an on-the-job reference for operators of these two types of treatment plants. The overall objective of the manual is to aid the operator in…

  12. WIM data analyst's manual

    DOT National Transportation Integrated Search

    2010-06-01

    This manual provides information and recommended procedures to be utilized by an agencys Weigh-in-Motion (WIM) Office Data Analyst to perform validation and quality control (QC) checks of WIM traffic data. This manual focuses on data generated by ...

  13. Manual for guided home exercises for osteoarthritis of the knee

    PubMed Central

    de Almeida Carvalho, Nilza Aparecida; Bittar, Simoni Teixeira; de Souza Pinto, Flávia Ribeiro; Ferreira, Mônica; Sitta, Robson Roberto

    2010-01-01

    INTRODUCTION: Physiotherapy is one of the most important components of therapy for osteoarthritis of the knee. The objective of this prospective case series was to assess the efficiency of a guidance manual for patients with osteoarthritis of the knee in relation to pain, range of movement , muscle strength and function, active goniometry, manual strength test and function. METHODS: Thirty-eight adults with osteoarthritis of the knee (≥ 45 years old) who were referred to the physiotherapy service at the university hospital (Santa Casa de Misericórdia de São Paulo) were studied. Patients received guidance for the practice of specific physical exercises and a manual with instructions on how to perform the exercises at home. They were evaluated for pain, range of movement, muscle strength and function. These evaluations were performed before they received the manual and three months later. Patients were seen monthly regarding improvements in their exercising abilities. RESULTS: The program was effective for improving muscle strength, controlling pain, maintaining range of movement of the knee joint, and reducing functional incapacity. DISCUSSION: A review of the literature showed that there are numerous clinical benefits to the regular practice of physical therapy exercises by patients with osteoarthritis of the knee(s) in a program with appropriate guidance. This study shows that this guidance can be attained at home with the use of a proper manual. CONCLUSIONS: Even when performed at home without constant supervision, the use of the printed manual for orientation makes the exercises for osteoarthritis of the knee beneficial. PMID:20835554

  14. Creating a systems engineering approach for the manual on uniform traffic control devices.

    DOT National Transportation Integrated Search

    2011-03-01

    The Manual on Uniform Traffic Control Devices (MUTCD) provides basic principles for use of traffic : control devices (TCD). However, most TCDs are not explicitly required, and the decision to use a given : TCD in a given situation is typically made b...

  15. Ornamental and Turf Pest Control for Commercial Applicators: Pest Control of Ornamental Plants; NCR 12, Lawn Diseases in the Midwest; NCR 26, Lawn Weeds and their Control. Manual 89.

    ERIC Educational Resources Information Center

    Craig, W. S., Comp.; And Others

    This training manual provides information needed to meet the minimum EPA standards for certification as a commercial applicator of pesticides in the ornamental and turf pest control category. The text discusses pest control of ornamental plants, lawn diseases, and lawn weeds and their control. (CS)

  16. Training children aged 5-10 years in manual compliance control to improve drawing and handwriting.

    PubMed

    Bingham, Geoffrey P; Snapp-Childs, Winona

    2018-04-12

    A large proportion of school-aged children exhibit poor drawing and handwriting. This prevalence limits the availability of therapy. We developed an automated method for training improved manual compliance control and relatedly, prospective control of a stylus. The approach included a difficult training task, while providing parametrically modifiable support that enables the children to perform successfully while developing good compliance control. The task was to use a stylus to push a bead along a 3D wire path. Support was provided by making the wire magnetically attractive to the stylus. Support was progressively reduced as 3D tracing performance improved. We report studies that (1) compared performance of Typically Developing (TD) children and children with Developmental Coordination Disorder (DCD), (2) tested training with active versus passive movement, (3) tested progressively reduced versus constant or no support during training, (4) tested children of different ages, (5) tested the transfer of training to a drawing task, (6) tested the specificity of training in respect to the size, shape and dimensionality of figures, and (7) investigated the relevance of the training task to the Beery VMI, an inventory used to diagnose DCD. The findings were as follows. (1) Pre-training performance of TD and DCD children was the same and good with high support but distinct and poor with low support. Support yielded good self-efficacy that motivated training. Post training performance with no support was improved and the same for TD and DCD children. (2) Actively controlled movements were required for improved performance. (3) Progressively reduced support was required for good performance during and after training. (4) Age differences in performance during pre-training were eliminated post-training. (5) Improvements transferred to drawing. (6) There was no evidence of specificity of training in transfer. (7) Disparate Beery scores were reflected in pre-training but not post-training performance. We conclude that the method improves manual compliance control, and more generally, prospective control of movements used in drawing performance. Copyright © 2018. Published by Elsevier B.V.

  17. Assessing consumption of bioactive micro-particles by filter-feeding Asian carp

    USGS Publications Warehouse

    Jensen, Nathan R.; Amberg, Jon J.; Luoma, James A.; Walleser, Liza R.; Gaikowski, Mark P.

    2012-01-01

    Silver carp Hypophthalmichthys molitrix (SVC) and bighead carp H. nobilis (BHC) have impacted waters in the US since their escape. Current chemical controls for aquatic nuisance species are non-selective. Development of a bioactive micro-particle that exploits filter-feeding habits of SVC or BHC could result in a new control tool. It is not fully understood if SVC or BHC will consume bioactive micro-particles. Two discrete trials were performed to: 1) evaluate if SVC and BHC consume the candidate micro-particle formulation; 2) determine what size they consume; 3) establish methods to evaluate consumption of filter-feeders for future experiments. Both SVC and BHC were exposed to small (50-100 μm) and large (150-200 μm) micro-particles in two 24-h trials. Particles in water were counted electronically and manually (microscopy). Particles on gill rakers were counted manually and intestinal tracts inspected for the presence of micro-particles. In Trial 1, both manual and electronic count data confirmed reductions of both size particles; SVC appeared to remove more small particles than large; more BHC consumed particles; SVC had fewer overall particles in their gill rakers than BHC. In Trial 2, electronic counts confirmed reductions of both size particles; both SVC and BHC consumed particles, yet more SVC consumed micro-particles compared to BHC. Of the fish that ate micro-particles, SVC consumed more than BHC. It is recommended to use multiple metrics to assess consumption of candidate micro-particles by filter-feeders when attempting to distinguish differential particle consumption. This study has implications for developing micro-particles for species-specific delivery of bioactive controls to help fisheries, provides some methods for further experiments with bioactive micro-particles, and may also have applications in aquaculture.

  18. Advanced figure sensor operations and maintenance manual

    NASA Technical Reports Server (NTRS)

    Robertson, H. J.

    1972-01-01

    This manual contains procedures for installing, operating, and maintaining the optical figure sensor and its associated electronic controls. The optical figure sensor, a system of integrated components, comprises: (1) a phase measuring modified interferometer employing a single frequency 6328 A laser, and a Vidissector; (2) a two-axis automatic thermal compensation control mount; (3) a five degree of freedom manual adjustment stand; and (4) a control console. This instrument provides real time output data of optical figure errors for spherical mirrors, and is also capable of measuring aspherical mirrors if a null corrector is added.

  19. Control technology appendices for pollution control technical manuals. Final report, June 1982-February 1983

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Not Available

    1983-04-01

    The document is one of six technical handbooks prepared by EPA to help government officials granting permits to build synfuels facilities, synfuels process developers, and other interested parties. They provide technical data on waste streams from synfuels facilities and technologies capable of controlling them. Process technologies covered in the manuals include coal gasification, coal liquefaction by direct and idirect processing, and the extraction of oil from shale. The manuals offer no regulatory guidance, allowing the industry flexibility in deciding how best to comply with environmental regulations.

  20. Manual calf massage and passive ankle motion reduce the incidence of deep vein thromboembolism after total hip arthroplasty.

    PubMed

    Imai, Norio; Ito, Tomoyuki; Suda, Ken; Miyasaka, Dai; Endo, Naoto

    2017-07-01

    Venous thromboembolism is one of the general complications following total hip arthroplasty, wherein various preventive treatments have been recommended. Several studies reported that venous thromboembolism incidence after total hip arthroplasty was similar in patients who were administered prophylaxis with a conventional mechanical procedure alone, and those who were administered pharmacological anticoagulation therapy. Therefore, the optimum methods of prophylaxis are still controversial. The purpose of this study was to investigate whether manual calf massage and passive ankle motion could lower the risk for venous thromboembolism after total hip arthroplasty. We retrospectively reviewed the data of 126 consecutive patients undergoing elective primary unilateral total hip arthroplasty wherein manual calf massage and passive ankle motion were performed after the surgery at our hospitals between January and October 2014. The 138 patients of the control group underwent total hip arthroplasty using the same surgical approach and pre- and postoperative protocols without this mechanical prophylaxis between January and December 2013. This mechanical prophylaxis was performed simultaneously 30 times during approximately 10 s; these procedures were repeated thrice immediately after total hip arthroplasty. Duplex ultrasonography was performed to observe the veins of both legs in all the patients on postoperative day 7. The incidence of deep vein thrombosis was 6.52% and 0.79% in the control and manual calf massage and passive ankle motion groups, respectively. The odds ratio for the manual calf massage and passive ankle motion groups was 8.72. Performing this mechanical prophylaxis reduced the incidence of venous thromboembolism after total hip arthroplasty. This mechanical prophylaxis is not only simple and easy, but is also safe and inexpensive. We therefore recommend that manual calf massage and passive ankle motion be performed in patients who will undergo total hip arthroplasty, if deep vein thrombosis does not exist before the surgery. Copyright © 2017 The Japanese Orthopaedic Association. Published by Elsevier B.V. All rights reserved.

  1. Manual Therapy in the Treatment of Idiopathic Scoliosis. Analysis of Current Knowledge.

    PubMed

    Czaprowski, Dariusz

    2016-10-28

    Apart from the recommended specific physiotherapy, the treatment of idiopathic scoliosis (IS) also incorporates non-specific manual therapy (NMT). The aim of this paper is to assess the efficacy of NMT (manual therapy, chiropractic, osteopathy) used in the treatment of children and adolescents with IS. The study analysed systematic reviews (Analysis 1) and other recent scientific publications (Analysis 2). Analysis 1 encompassed papers on the use of NMT in patients with IS. Works concerning specific physiotherapy (SP) or bracing (B) and other types of scoliosis were excluded from the analysis. Inclusion criteria for Analysis 2 were: treatment with NMT; subjects aged 10-18 years with IS. The following types of papers were excluded: works analysing NMT combined with SP or B, reports concerning adult pa tients, analyses of single cases and publications included in Analysis 1. Analysis 1: six systematic reviews contained 6 papers on the efficacy of NMT in the treatment of IS. The results of these studies are contradictory, ranging from Cobb angle reduction to no treatment effects whatsoever. The papers analysed are characterised by poor methodological quality: small group sizes, incomplete descriptions of the study groups, no follow-up and no control groups. Analysis 2: in total, 217 papers were found. None of them met the criteria set for the analysis. 1. Few papers verifying the efficacy of manual therapy, chiropractic and osteopathy in the treatment of idiopathic scoliosis have been published to date. 2. The majority are experimental studies with poor methodology or observational case studies. 3. At present, the efficacy of non-specific manual therapy in the treatment of patients with idiopathic scoliosis cannot be reliably evaluated. 4. It is necessary to conduct further research based on appropriate methods (prospective, rando mi s ed, controlled studies) in order to reliably assess the usefulness of non-specific manual therapy in the treatment of idiopathic scoliosis.

  2. 7 CFR 91.23 - Analytical methods.

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... 7 Agriculture 3 2014-01-01 2014-01-01 false Analytical methods. 91.23 Section 91.23 Agriculture... SERVICES AND GENERAL INFORMATION Method Manuals § 91.23 Analytical methods. Most analyses are performed according to approved procedures described in manuals of standardized methodology. These standard methods...

  3. 7 CFR 91.23 - Analytical methods.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... 7 Agriculture 3 2011-01-01 2011-01-01 false Analytical methods. 91.23 Section 91.23 Agriculture... SERVICES AND GENERAL INFORMATION Method Manuals § 91.23 Analytical methods. Most analyses are performed according to approved procedures described in manuals of standardized methodology. These standard methods...

  4. 7 CFR 91.23 - Analytical methods.

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... 7 Agriculture 3 2013-01-01 2013-01-01 false Analytical methods. 91.23 Section 91.23 Agriculture... SERVICES AND GENERAL INFORMATION Method Manuals § 91.23 Analytical methods. Most analyses are performed according to approved procedures described in manuals of standardized methodology. These standard methods...

  5. Use of the white amur for aquatic plant management. Final report

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Miller, A.C.; Decell, J.L.

    1984-08-01

    The manual presents practical guidelines for the use of the white amur to manage aquatic vegetation in lakes and ponds. This document will introduce the reader to the white amur as a biological control agent for submersed aquatic plants, and present information necessary for successful use of the fish. Included are methods for calculating the number of fish required to effect a desired level of plant control, as well as information on obtaining, shipping, and releasing white amur. Data on feeding, growth rates, food preferences, reproduction, and tolerances to various aquatic conditions are also presented. Case studies on the usemore » of the fish are discussed to illustrate possible impacts of white amur on water chemistry and native biota. While the majority of the information for this report originated in Lake Conway, Florida, the fish is a viable control agent in other parts of the country. This manual should have utility in all parts of the United States in providing background data on the white amur and concise information on the proper use of fish to control submersed aquatic plants. 122 references.« less

  6. Automated registration of multispectral MR vessel wall images of the carotid artery

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Klooster, R. van 't; Staring, M.; Reiber, J. H. C.

    2013-12-15

    Purpose: Atherosclerosis is the primary cause of heart disease and stroke. The detailed assessment of atherosclerosis of the carotid artery requires high resolution imaging of the vessel wall using multiple MR sequences with different contrast weightings. These images allow manual or automated classification of plaque components inside the vessel wall. Automated classification requires all sequences to be in alignment, which is hampered by patient motion. In clinical practice, correction of this motion is performed manually. Previous studies applied automated image registration to correct for motion using only nondeformable transformation models and did not perform a detailed quantitative validation. The purposemore » of this study is to develop an automated accurate 3D registration method, and to extensively validate this method on a large set of patient data. In addition, the authors quantified patient motion during scanning to investigate the need for correction. Methods: MR imaging studies (1.5T, dedicated carotid surface coil, Philips) from 55 TIA/stroke patients with ipsilateral <70% carotid artery stenosis were randomly selected from a larger cohort. Five MR pulse sequences were acquired around the carotid bifurcation, each containing nine transverse slices: T1-weighted turbo field echo, time of flight, T2-weighted turbo spin-echo, and pre- and postcontrast T1-weighted turbo spin-echo images (T1W TSE). The images were manually segmented by delineating the lumen contour in each vessel wall sequence and were manually aligned by applying throughplane and inplane translations to the images. To find the optimal automatic image registration method, different masks, choice of the fixed image, different types of the mutual information image similarity metric, and transformation models including 3D deformable transformation models, were evaluated. Evaluation of the automatic registration results was performed by comparing the lumen segmentations of the fixed image and moving image after registration. Results: The average required manual translation per image slice was 1.33 mm. Translations were larger as the patient was longer inside the scanner. Manual alignment took 187.5 s per patient resulting in a mean surface distance of 0.271 ± 0.127 mm. After minimal user interaction to generate the mask in the fixed image, the remaining sequences are automatically registered with a computation time of 52.0 s per patient. The optimal registration strategy used a circular mask with a diameter of 10 mm, a 3D B-spline transformation model with a control point spacing of 15 mm, mutual information as image similarity metric, and the precontrast T1W TSE as fixed image. A mean surface distance of 0.288 ± 0.128 mm was obtained with these settings, which is very close to the accuracy of the manual alignment procedure. The exact registration parameters and software were made publicly available. Conclusions: An automated registration method was developed and optimized, only needing two mouse clicks to mark the start and end point of the artery. Validation on a large group of patients showed that automated image registration has similar accuracy as the manual alignment procedure, substantially reducing the amount of user interactions needed, and is multiple times faster. In conclusion, the authors believe that the proposed automated method can replace the current manual procedure, thereby reducing the time to analyze the images.« less

  7. Field manual for the collection of Navajo Nation streamflow-gage data

    USGS Publications Warehouse

    Hart, Robert J.; Fisk, Gregory G.

    2014-01-01

    The Field Manual for the Collection of Navajo Nation Streamflow-Gage Data (Navajo Field Manual) is based on established (standard) U.S. Geological Survey streamflow-gaging methods and provides guidelines specifically designed for the Navajo Department of Water Resources personnel who establish and maintain streamflow gages. The Navajo Field Manual addresses field visits, including essential field equipment and the selection of and routine visits to streamflow-gaging stations, examines surveying methods for determining peak flows (indirect measurements), discusses safety considerations, and defines basic terms.

  8. California Publicly-Owned Utilities (POUs) – LBNL ‘Beyond Widgets’ Project. Task: ambient lighting and occupancy-based plug load control. System Program Manual

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Robinson, Alastair; Mathew, Paul A.; Regnier, Cynthia

    This program manual contains detailed technical information for implementing an incentive program for task-ambient lighting and occupancy-based plug load control. This manual was developed by Lawrence Berkeley National Laboratory, in collaboration with the California Publicly-Owned Utilities (CA POUs) as a partner in the ‘Beyond Widgets’ program funded by the U.S. Department of Energy Building Technologies Office. The primary audience for this manual is the program staff of the various CA POUs. It may also be used by other utility incentive programs to help develop similar programs. It is anticipated that the content of this manual be utilized by the CAmore » POU staff for developing related documents such as the Technical Resource Manual and other filings pertaining to the rollout of an energy systems-based rebate incentive program.« less

  9. Safe, Effective Use of Pesticides, A Manual for Commercial Applicators: Ornamental and Turf Pest Control.

    ERIC Educational Resources Information Center

    Extension Service (USDA), Washington, DC.

    This manual is intended to assist pesticide applicators in the area of ornamental and turf pest control prepare for certification under the Michigan Pesticide Control Act of 1976. The three sections presented describe: (1) Ornamentals; (2) Turfgrass; and (3) Pest Control. Section one discusses the diagnostic chart for plant problems, non-pest…

  10. 78 FR 41285 - Airworthiness Directives; Pilatus Aircraft Ltd. Airplanes

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-07-10

    ... manual). The limitations were revised to include an emergency fuel control system adjustment test. We are... a 300 Flight Hour (FH) hour inspection on the Emergency Fuel Control System (FCS). For the reason...., maintenance manual). The limitations were revised to include an emergency fuel control system adjustment test...

  11. 76 FR 46213 - National Standards for Traffic Control Devices; the Manual on Uniform Traffic Control Devices for...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-08-02

    ... design and application of traffic control devices, this Manual should not be considered a substitute for... retroreflectivity of longitudinal pavement markings. The deadline for comments to that docket has passed and the... the proposed revisions regarding maintaining minimum retroreflectivity of longitudinal pavement...

  12. Computer Numerical Control: Instructional Manual. The North Dakota High Technology Mobile Laboratory Project.

    ERIC Educational Resources Information Center

    Sinn, John W.

    This instructional manual contains five learning activity packets for use in a workshop on computer numerical control for computer-aided manufacturing. The lessons cover the following topics: introduction to computer-aided manufacturing, understanding the lathe, using the computer, computer numerically controlled part programming, and executing a…

  13. Cost Control. Michigan School Food Service Training Manual.

    ERIC Educational Resources Information Center

    Michigan State Univ., East Lansing. Cooperative Extension Service.

    Cost control is the subject of this eight-lesson, three-test food service training manual. Lesson 1 deals with financial accountability and includes 17 handouts, ranging from sample balance to quarterly report sheets. Lesson 2 focuses on budgeting principles, and lesson 3 on labor controls. Professional purchasing, receiving, and inventorying…

  14. Anaerobic Digestion. Student Manual. Biological Treatment Process Control.

    ERIC Educational Resources Information Center

    Carnegie, John W., Ed.

    This student manual contains the textual material for a four-lesson unit on anaerobic digestion control. Areas addressed include: (1) anaerobic sludge digestion (considering the nature of raw sludge, purposes of anaerobic digestion, the results of digestion, types of equipment, and other topics); (2) digester process control (considering feeding…

  15. Navy Occupational Health Information Management System (NOHIMS). Hazardous Materials Control Module. Users’ Manual

    DTIC Science & Technology

    1987-01-16

    Occupational Health Information Management System (NOHIMS) 6 Hazardous Materials Control Module (HMC) User’s Manual 7. Author(s) 8. Performing Organization...Materials Control (HMC) module of the Naval Medical Command’s (NAVMED) Navy Occupational Health Information Management System (NOHIMS). After presenting

  16. Intelligent guidance and control for wind shear encounter

    NASA Technical Reports Server (NTRS)

    Stengel, Robert F.

    1988-01-01

    The principal objective is to develop methods for assessing the likelihood of wind shear encounter, for deciding what flight path to pursue, and for using the aircraft's full potential for combating wind shear. This study requires the definition of both deterministic and statistical techniques for fusing internal and external information, for making go/no-go decisions, and for generating commands to the aircraft's cockpit displays and autopilot for both manually controlled and automatic flight. The program has begun with the development of a real-time expert system for pilot aiding that is based on the results of the FAA Windshear Training Aids Program. A two-volume manual that presents an overview, pilot guide, training program, and substantiating data provides guidelines for this initial development. The Expert System to Avoid Wind Shear (ESAWS) currently contains over 140 rules and is coded in the LISP programming language for implementation on a Symbolics 3670 LISP machine.

  17. Auto-tuning system for NMR probe with LabView

    NASA Astrophysics Data System (ADS)

    Quen, Carmen; Mateo, Olivia; Bernal, Oscar

    2013-03-01

    Typical manual NMR-tuning method is not suitable for broadband spectra spanning several megahertz linewidths. Among the main problems encountered during manual tuning are pulse-power reproducibility, baselines, and transmission line reflections, to name a few. We present a design of an auto-tuning system using graphic programming language, LabVIEW, to minimize these problems. The program is designed to analyze the detected power signal of an antenna near the NMR probe and use this analysis to automatically tune the sample coil to match the impedance of the spectrometer (50 Ω). The tuning capacitors of the probe are controlled by a stepper motor through a LabVIEW/computer interface. Our program calculates the area of the power signal as an indicator to control the motor so disconnecting the coil to tune it through a network analyzer is unnecessary. Work supported by NSF-DMR 1105380

  18. Identification and analysis of unsatisfactory psychosocial work situations: a participatory approach employing video-computer interaction.

    PubMed

    Hanse, J J; Forsman, M

    2001-02-01

    A method for psychosocial evaluation of potentially stressful or unsatisfactory situations in manual work was developed. It focuses on subjective responses regarding specific situations and is based on interactive worker assessment when viewing video recordings of oneself. The worker is first video-recorded during work. The video is then displayed on the computer terminal, and the filmed worker clicks on virtual controls on the screen whenever an unsatisfactory psychosocial situation appears; a window of questions regarding psychological demands, mental strain and job control is then opened. A library with pictorial information and comments on the selected situations is formed in the computer. The evaluation system, called PSIDAR, was applied in two case studies, one of manual materials handling in an automotive workshop and one of a group of workers producing and testing instrument panels. The findings indicate that PSIDAR can provide data that are useful in a participatory ergonomic process of change.

  19. A Fully Automated Drosophila Olfactory Classical Conditioning and Testing System for Behavioral Learning and Memory Assessment

    PubMed Central

    Jiang, Hui; Hanna, Eriny; Gatto, Cheryl L.; Page, Terry L.; Bhuva, Bharat; Broadie, Kendal

    2016-01-01

    Background Aversive olfactory classical conditioning has been the standard method to assess Drosophila learning and memory behavior for decades, yet training and testing are conducted manually under exceedingly labor-intensive conditions. To overcome this severe limitation, a fully automated, inexpensive system has been developed, which allows accurate and efficient Pavlovian associative learning/memory analyses for high-throughput pharmacological and genetic studies. New Method The automated system employs a linear actuator coupled to an odorant T-maze with airflow-mediated transfer of animals between training and testing stages. Odorant, airflow and electrical shock delivery are automatically administered and monitored during training trials. Control software allows operator-input variables to define parameters of Drosophila learning, short-term memory and long-term memory assays. Results The approach allows accurate learning/memory determinations with operational fail-safes. Automated learning indices (immediately post-training) and memory indices (after 24 hours) are comparable to traditional manual experiments, while minimizing experimenter involvement. Comparison with Existing Methods The automated system provides vast improvements over labor-intensive manual approaches with no experimenter involvement required during either training or testing phases. It provides quality control tracking of airflow rates, odorant delivery and electrical shock treatments, and an expanded platform for high-throughput studies of combinational drug tests and genetic screens. The design uses inexpensive hardware and software for a total cost of ~$500US, making it affordable to a wide range of investigators. Conclusions This study demonstrates the design, construction and testing of a fully automated Drosophila olfactory classical association apparatus to provide low-labor, high-fidelity, quality-monitored, high-throughput and inexpensive learning and memory behavioral assays. PMID:26703418

  20. Forest Pest Control. Manual 94.

    ERIC Educational Resources Information Center

    Missouri Univ., Columbia. Agricultural Experiment Station.

    This training manual provides information needed to meet the minimum EPA standards for certification as a commercial applicator of pesticides in forest pest control. The text discusses disease problems, insects, and herbicide use in both established forests and nurseries. (CS)

  1. Dispelling Rumours Around Zika and Complications

    MedlinePlus

    ... the spread and control of disease. WHO’s Vector Control Advisory Group is preparing a manual on how best to design such studies. The manual will be released later this year. ... populations. WHO encourages affected countries and their ...

  2. Evaluation of three automatic oxygen therapy control algorithms on ventilated low birth weight neonates.

    PubMed

    Morozoff, Edmund P; Smyth, John A

    2009-01-01

    Neonates with under developed lungs often require oxygen therapy. During the course of oxygen therapy, elevated levels of blood oxygenation, hyperoxemia, must be avoided or the risk of chronic lung disease or retinal damage is increased. Low levels of blood oxygen, hypoxemia, may lead to permanent brain tissue damage and, in some cases, mortality. A closed loop controller that automatically administers oxygen therapy using 3 algorithms - state machine, adaptive model, and proportional integral derivative (PID) - is applied to 7 ventilated low birth weight neonates and compared to manual oxygen therapy. All 3 automatic control algorithms demonstrated their ability to improve manual oxygen therapy by increasing periods of normoxemia and reducing the need for manual FiO(2) adjustments. Of the three control algorithms, the adaptive model showed the best performance with 0.25 manual adjustments per hour and 73% time spent within target +/- 3% SpO(2).

  3. A macro-micro robot for precise force applications

    NASA Technical Reports Server (NTRS)

    Marzwell, Neville I.; Wang, Yulun

    1993-01-01

    This paper describes an 8 degree-of-freedom macro-micro robot capable of performing tasks which require accurate force control. Applications such as polishing, finishing, grinding, deburring, and cleaning are a few examples of tasks which need this capability. Currently these tasks are either performed manually or with dedicated machinery because of the lack of a flexible and cost effective tool, such as a programmable force-controlled robot. The basic design and control of the macro-micro robot is described in this paper. A modular high-performance multiprocessor control system was designed to provide sufficient compute power for executing advanced control methods. An 8 degree of freedom macro-micro mechanism was constructed to enable accurate tip forces. Control algorithms based on the impedance control method were derived, coded, and load balanced for maximum execution speed on the multiprocessor system.

  4. 46 CFR 161.002-12 - Manual fire alarm systems.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    .... (a) General. A manual fire alarm system shall consist of a power supply, a control unit on which are... using manually operated fire alarm boxes. (3) Other types as may be developed. (c) Power supply. The power supply shall be as specified for automatic fire detecting system by § 161.002-9. (d) Manual fire...

  5. 46 CFR 161.002-12 - Manual fire alarm systems.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    .... (a) General. A manual fire alarm system shall consist of a power supply, a control unit on which are... using manually operated fire alarm boxes. (3) Other types as may be developed. (c) Power supply. The power supply shall be as specified for automatic fire detecting system by § 161.002-9. (d) Manual fire...

  6. Stereophotogrammetry in studies of riparian vegetation dynamics

    NASA Astrophysics Data System (ADS)

    Hortobagyi, Borbala; Vautier, Franck; Corenblit, Dov; Steiger, Johannes

    2014-05-01

    Riparian vegetation responds to hydrogeomorphic disturbances and also controls sediment deposition and erosion. Spatio-temporal riparian vegetation dynamics within fluvial corridors have been quantified in many studies using aerial photographs and GIS. However, this approach does not allow the consideration of woody vegetation growth rates (i.e. vertical dimension) which are fundamental when studying feedbacks between the processes of fluvial landform construction and vegetation establishment and succession. We built 3D photogrammetric models of vegetation height based on aerial argentic and digital photographs from sites of the Allier and Garonne Rivers (France). The models were realized at two different spatial scales and with two different methods. The "large" scale corresponds to the reach of the river corridor on the Allier river (photograph taken in 2009) and the "small" scale to river bars of the Allier (photographs taken in 2002, 2009) and Garonne Rivers (photographs taken in 2000, 2002, 2006 and 2010). At the corridor scale, we generated vegetation height models using an automatic procedure. This method is fast but can only be used with digital photographs. At the bar scale, we constructed the models manually using a 3D visualization on the screen. This technique showed good results for digital and also argentic photographs but is very time-consuming. A diachronic study was performed in order to investigate vegetation succession by distinguishing three different classes according to the vegetation height: herbs (<1 m), shrubs (1-4 m) or trees (>4 m). Both methods, i.e. automatic and manual, were employed to study the evolution of the three vegetation classes and the recruitment of new vegetation patches. A comparison was conducted between the vegetation height given by models (automatic and manual) and the vegetation height measured in the field. The manually produced models (small scale) were of a precision of 0.5-1 m, allowing the quantification of woody vegetation growth rates. Thus, our results show that the manual method we developed is accurate to quantify vegetation growth rates at small scales, whereas the less accurate automatic method is appropriate to study vegetation succession at the corridor scale. Both methods are complementary and will contribute to a further exploration of the mutual relationships between hydrogeomorphic processes, topography and vegetation dynamics within alluvial systems, adding the quantification of the vertical dimension of riparian vegetation to their spatio-temporal characteristics.

  7. Internal and external cooling methods and their effect on body temperature, thermal perception and dexterity

    PubMed Central

    Minett, Geoffrey M.; Bach, Aaron J. E.; Zietek, Stephanie A.; Stewart, Kelly L.; Stewart, Ian B.

    2018-01-01

    Objective The present study aimed to compare a range of cooling methods possibly utilised by occupational workers, focusing on their effect on body temperature, perception and manual dexterity. Methods Ten male participants completed eight trials involving 30 min of seated rest followed by 30 min of cooling or control of no cooling (CON) (34°C, 58% relative humidity). The cooling methods utilised were: ice cooling vest (CV0), phase change cooling vest melting at 14°C (CV14), evaporative cooling vest (CVEV), arm immersion in 10°C water (AI), portable water-perfused suit (WPS), heliox inhalation (HE) and ice slushy ingestion (SL). Immediately before and after cooling, participants were assessed for fine (Purdue pegboard task) and gross (grip and pinch strength) manual dexterity. Rectal and skin temperature, as well as thermal sensation and comfort, were monitored throughout. Results Compared with CON, SL was the only method to reduce rectal temperature (P = 0.012). All externally applied cooling methods reduced skin temperature (P<0.05), though CV0 resulted in the lowest skin temperature versus other cooling methods. Participants felt cooler with CV0, CV14, WPS, AI and SL (P<0.05). AI significantly impaired Purdue pegboard performance (P = 0.001), but did not affect grip or pinch strength (P>0.05). Conclusion The present study observed that ice ingestion or ice applied to the skin produced the greatest effect on rectal and skin temperature, respectively. AI should not be utilised if workers require subsequent fine manual dexterity. These results will help inform future studies investigating appropriate pre-cooling methods for the occupational worker. PMID:29357373

  8. Launch Vehicle Manual Steering with Adaptive Augmenting Control In-flight Evaluations of Adverse Interactions Using a Piloted Aircraft

    NASA Technical Reports Server (NTRS)

    Hanson, Curt; Miller, Chris; Wall, John H.; Vanzwieten, Tannen S.; Gilligan, Eric; Orr, Jeb S.

    2015-01-01

    An adaptive augmenting control algorithm for the Space Launch System has been developed at the Marshall Space Flight Center as part of the launch vehicles baseline flight control system. A prototype version of the SLS flight control software was hosted on a piloted aircraft at the Armstrong Flight Research Center to demonstrate the adaptive controller on a full-scale realistic application in a relevant flight environment. Concerns regarding adverse interactions between the adaptive controller and a proposed manual steering mode were investigated by giving the pilot trajectory deviation cues and pitch rate command authority. Two NASA research pilots flew a total of twenty five constant pitch-rate trajectories using a prototype manual steering mode with and without adaptive control.

  9. Resource Manual: Handicapped Children Birth to Five. Part 2.

    ERIC Educational Resources Information Center

    Leslie, Lin; And Others

    The resource manual, in two parts, provides a compilation of methods for enhancing the development of handicapped children from birth to 5 years in the areas of motor, communication, cognition, self help, and social skills. The manual is intended to aid in (1) assessing and identifying target behaviors to be achieved, (2) identifying methods for…

  10. Strength training alone, exercise therapy alone, and exercise therapy with passive manual mobilisation each reduce pain and disability in people with knee osteoarthritis: a systematic review.

    PubMed

    Jansen, Mariette J; Viechtbauer, Wolfgang; Lenssen, Antoine F; Hendriks, Erik J M; de Bie, Rob A

    2011-01-01

    What are the effects of strength training alone, exercise therapy alone, and exercise with additional passive manual mobilisation on pain and function in people with knee osteoarthritis compared to control? What are the effects of these interventions relative to each other? A meta-analysis of randomised controlled trials. Adults with osteoarthritis of the knee. INTERVENTION TYPES: Strength training alone, exercise therapy alone (combination of strength training with active range of motion exercises and aerobic activity), or exercise with additional passive manual mobilisation, versus any non-exercise control. Comparisons between the three interventions were also sought. The primary outcome measures were pain and physical function. 12 trials compared one of the interventions against control. The effect size on pain was 0.38 (95% CI 0.23 to 0.54) for strength training, 0.34 (95% CI 0.19 to 0.49) for exercise, and 0.69 (95% CI 0.42 to 0.96) for exercise plus manual mobilisation. Each intervention also improved physical function significantly. No randomised comparisons of the three interventions were identified. However, meta-regression indicated that exercise plus manual mobilisations improved pain significantly more than exercise alone (p = 0.03). The remaining comparisons between the three interventions for pain and physical function were not significant. Exercise therapy plus manual mobilisation showed a moderate effect size on pain compared to the small effect sizes for strength training or exercise therapy alone. To achieve better pain relief in patients with knee osteoarthritis physiotherapists or manual therapists might consider adding manual mobilisation to optimise supervised active exercise programs. Copyright © 2011 Australian Physiotherapy Association. Published by .. All rights reserved.

  11. CSTEM User Manual

    NASA Technical Reports Server (NTRS)

    Hartle, M.; McKnight, R. L.

    2000-01-01

    This manual is a combination of a user manual, theory manual, and programmer manual. The reader is assumed to have some previous exposure to the finite element method. This manual is written with the idea that the CSTEM (Coupled Structural Thermal Electromagnetic-Computer Code) user needs to have a basic understanding of what the code is actually doing in order to properly use the code. For that reason, the underlying theory and methods used in the code are described to a basic level of detail. The manual gives an overview of the CSTEM code: how the code came into existence, a basic description of what the code does, and the order in which it happens (a flowchart). Appendices provide a listing and very brief description of every file used by the CSTEM code, including the type of file it is, what routine regularly accesses the file, and what routine opens the file, as well as special features included in CSTEM.

  12. The modulation of brain functional connectivity with manual acupuncture in healthy subjects: An electroencephalograph case study

    NASA Astrophysics Data System (ADS)

    Yi, Guo-Sheng; Wang, Jiang; Han, Chun-Xiao; Deng, Bin; Wei, Xi-Le; Li, Nuo

    2013-02-01

    Manual acupuncture is widely used for pain relief and stress control. Previous studies on acupuncture have shown its modulatory effects on the functional connectivity associated with one or a few preselected brain regions. To investigate how manual acupuncture modulates the organization of functional networks at a whole-brain level, we acupuncture at ST36 of a right leg to obtain electroencephalograph (EEG) signals. By coherence estimation, we determine the synchronizations between all pairwise combinations of EEG channels in three acupuncture states. The resulting synchronization matrices are converted into functional networks by applying a threshold, and the clustering coefficients and path lengths are computed as a function of threshold. The results show that acupuncture can increase functional connections and synchronizations between different brain areas. For a wide range of thresholds, the clustering coefficient during acupuncture and post-acupuncture period is higher than that during the pre-acupuncture control period, whereas the characteristic path length is shorter. We provide further support for the presence of “small-world" network characteristics in functional networks by using acupuncture. These preliminary results highlight the beneficial modulations of functional connectivity by manual acupuncture, which could contribute to the understanding of the effects of acupuncture on the entire brain, as well as the neurophysiological mechanisms underlying acupuncture. Moreover, the proposed method may be a useful approach to the further investigation of the complexity of patterns of interrelations between EEG channels.

  13. Comparison of Manual Refraction Versus Autorefraction in 60 Diabetic Retinopathy Patients.

    PubMed

    Shirzadi, Keyvan; Shahraki, Kourosh; Yahaghi, Emad; Makateb, Ali; Khosravifard, Keivan

    2016-07-27

    The purpose of the study was to evaluate the comparison of manual refraction versus autorefraction in diabetic retinopathy patients. The study was conducted at the Be'sat Army Hospital from 2013-2015. In the present study differences between two common refractometry methods (manual refractometry and Auto refractometry) in diagnosis and follow up of retinopathy in patients affected with diabetes is investigated. Our results showed that there is a significant difference in visual acuity score of patients between manual and auto refractometry. Despite this fact, spherical equivalent scores of two methods of refractometry did not show a significant statistical difference in the patients. Although use of manual refraction is comparable with autorefraction in evaluating spherical equivalent scores in diabetic patients affected with retinopathy, but in the case of visual acuity results from these two methods are not comparable.

  14. Ada Software Design Methods Formulation.

    DTIC Science & Technology

    1982-10-01

    aside for one-to-one, non -judgemental discussions between SofTech and the design teams. SofTech’s role in the meetings was to address any Ada-specific...assurance 1.0 prepare version audits 1.0 monitoring contracts 1.0 library control 1.0 other development 1.0 correspondence 1.0 conduct support design ...quality assurance 2.0 Control Board update training manuals 2.0 participation 2.5 being trained 2.0 formulation of policy 2.5 functional system design

  15. 26. DETAIL VIEW OF THE ADJUSTABLE FIELD RESISTTOR MANUAL CONTROLS ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    26. DETAIL VIEW OF THE ADJUSTABLE FIELD RESISTTOR MANUAL CONTROLS AND SWITCH BOXES. - Potomac Power Plant, On West Virginia Shore of Potomac River, about 1 mile upriver from confluence with Shenandoah River, Harpers Ferry, Jefferson County, WV

  16. 75 FR 72822 - Nationwide Categorical Waivers Under Section 1605 (Buy American) of the American Recovery and...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-11-26

    ... a temperature range of 15-55 degrees Fahrenheit and manual reset; (4) Programmable DDC controllers... manual reset; (4) Programmable DDC controllers for LON protocol, where an existing LON system exists that...

  17. A users manual for the method of moments Aircraft Modeling Code (AMC), version 2

    NASA Technical Reports Server (NTRS)

    Peters, M. E.; Newman, E. H.

    1994-01-01

    This report serves as a user's manual for Version 2 of the 'Aircraft Modeling Code' or AMC. AMC is a user-oriented computer code, based on the method of moments (MM), for the analysis of the radiation and/or scattering from geometries consisting of a main body or fuselage shape with attached wings and fins. The shape of the main body is described by defining its cross section at several stations along its length. Wings, fins, rotor blades, and radiating monopoles can then be attached to the main body. Although AMC was specifically designed for aircraft or helicopter shapes, it can also be applied to missiles, ships, submarines, jet inlets, automobiles, spacecraft, etc. The problem geometry and run control parameters are specified via a two character command language input format. This report describes the input command language and also includes several examples which illustrate typical code inputs and outputs.

  18. A user's manual for the method of moments Aircraft Modeling Code (AMC)

    NASA Technical Reports Server (NTRS)

    Peters, M. E.; Newman, E. H.

    1989-01-01

    This report serves as a user's manual for the Aircraft Modeling Code or AMC. AMC is a user-oriented computer code, based on the method of moments (MM), for the analysis of the radiation and/or scattering from geometries consisting of a main body or fuselage shape with attached wings and fins. The shape of the main body is described by defining its cross section at several stations along its length. Wings, fins, rotor blades, and radiating monopoles can then be attached to the main body. Although AMC was specifically designed for aircraft or helicopter shapes, it can also be applied to missiles, ships, submarines, jet inlets, automobiles, spacecraft, etc. The problem geometry and run control parameters are specified via a two character command language input format. The input command language is described and several examples which illustrate typical code inputs and outputs are also included.

  19. Dose Response Effects of Lisdexamfetamine Dimesylate Treatment in Adults with ADHD: An Exploratory Study

    ERIC Educational Resources Information Center

    Faraone, Stephen V.; Spencer, Thomas J.; Kollins, Scott H.; Glatt, Stephen J.; Goodman, David

    2012-01-01

    Objective: To explore dose-response effects of lisdexamfetamine dimesylate (LDX) treatment for ADHD. Method: This was a 4-week, randomized, double-blinded, placebo-controlled, parallel-group, forced-dose titration study in adult participants, aged 18 to 55 years, meeting "Diagnostic and Statistical Manual of Mental Disorders" (4th ed., text rev.)…

  20. 40 CFR Appendix Ix to Part 266 - Methods Manual for Compliance With the BIF Regulations

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... Systems 2.1Performance Specifications for Continuous Emission Monitoring of Carbon Monoxide and Oxygen for... Methodology for Bevill Residue Determinations 8.0Procedures for Determining Default Values for Air Pollution Control System Removal Efficiencies 8.1APCS RE Default Values for Metals 8.2APCS RE Default Values for HC1...

  1. 40 CFR Appendix Ix to Part 266 - Methods Manual for Compliance With the BIF Regulations

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... Systems 2.1Performance Specifications for Continuous Emission Monitoring of Carbon Monoxide and Oxygen for... Methodology for Bevill Residue Determinations 8.0Procedures for Determining Default Values for Air Pollution Control System Removal Efficiencies 8.1APCS RE Default Values for Metals 8.2APCS RE Default Values for HC1...

  2. DETERMINATION OF SULFUR DIOXIDE, NITROGEN OXIDES, AND CARBON DIOXIDE IN EMISSIONS FROM ELECTRIC UTILITY PLANTS BY ALKALINE PERMANGANATE SAMPLING AND ION CHROMATOGRAPHY

    EPA Science Inventory

    A manual 24-h integrated method for determining SO2, NOx, and CO2 in emissions from electric utility plants was developed and field tested downstream from an SO2 control system. Samples were collected in alkaline potassium permanganate solution contained in restricted-orifice imp...

  3. [Report quality of randomized controlled trials of moxibustion for knee osteoarthritis based on CONSORT and STRICTOM].

    PubMed

    Xiong, Jun; Zhu, Daocheng; Chen, Rixin; Ye, Wenguo

    2015-08-01

    The report quality of randomized controlled trials (RCTs) of moxibustion for knee osteoarthritis (KOA) in China was evaluated by Consolidated Standards for Reporting of Trials (CONSORT) and Standards for Reporting Interventions in Controlled Trials of Moxibustion (STRICTOM). Computer and manual retrieval was used. Four databases of China National Knowledge Infrastructure (CNKD, China Biomedicine (CBM), VIP and WNFANG were searched in combination with manual retrieval for relevant journals to screen the literature that: met the inclusive criteria, and CONSORT and STRICTOM were used to assess the report quality. A total of 52 RCTs were included. It was found that unclear description of random methods, low use of blind methods, no allocation concealment, no sample size calculation, no intention-to-treat analysis,inadequate report of moxibustion details and no mention of practitioners background existed in the majority of the RCTs. Although the quality of RCTs of moxibustion for KOA was generally low, reducing the reliability and homogeneous comparability of the reports ,the quality of heat-sensitive moxibustion RCTs was high. It was believed that in order to improve the reliability and quality of RCTs of moxibustion, CONSORT and STRICTOM should be introduced into the RCT design of moxibustion and be strictly performed.

  4. FLAPS (Fatigue Life Analysis Programs): Computer Programs to Predict Cyclic Life Using the Total Strain Version of Strainrange Partitioning and Other Life Prediction Methods. Users' Manual and Example Problems, Version 1.0

    NASA Technical Reports Server (NTRS)

    Arya, Vinod K.; Halford, Gary R. (Technical Monitor)

    2003-01-01

    This manual presents computer programs FLAPS for characterizing and predicting fatigue and creep-fatigue resistance of metallic materials in the high-temperature, long-life regime for isothermal and nonisothermal fatigue. The programs use the Total Strain version of Strainrange Partitioning (TS-SRP), and several other life prediction methods described in this manual. The user should be thoroughly familiar with the TS-SRP and these life prediction methods before attempting to use any of these programs. Improper understanding can lead to incorrect use of the method and erroneous life predictions. An extensive database has also been developed in a parallel effort. The database is probably the largest source of high-temperature, creep-fatigue test data available in the public domain and can be used with other life-prediction methods as well. This users' manual, software, and database are all in the public domain and can be obtained by contacting the author. The Compact Disk (CD) accompanying this manual contains an executable file for the FLAPS program, two datasets required for the example problems in the manual, and the creep-fatigue data in a format compatible with these programs.

  5. Motion planning and synchronized control of the dental arch generator of the tooth-arrangement robot.

    PubMed

    Jiang, Jin-Gang; Zhang, Yong-De

    2013-03-01

    The traditional, manual method of reproducing the dental arch form is prone to numerous random errors caused by human factors. The purpose of this study was to investigate the automatic acquisition of the dental arch and implement the motion planning and synchronized control of the dental arch generator of the multi-manipulator tooth-arrangement robot for use in full denture manufacture. First, the mathematical model of the dental arch generator was derived. Then the kinematics and control point position of the dental arch generator of the tooth arrangement robot were calculated and motion planning of each control point was analysed. A hardware control scheme is presented, based on the industrial personal computer and control card PC6401. In order to gain single-axis, precise control of the dental arch generator, we studied the control pulse realization of high-resolution timing. Real-time, closed-loop, synchronous control was applied to the dental arch generator. Experimental control of the dental arch generator and preliminary tooth arrangement were gained by using the multi-manipulator tooth-arrangement robotic system. The dental arch generator can automatically generate a dental arch to fit a patient according to the patient's arch parameters. Repeated positioning accuracy is 0.12 mm for the slipways that drive the dental arch generator. The maximum value of single-point error is 1.83 mm, while the arc-width direction (x axis) is -33.29 mm. A novel system that generates the dental arch has been developed. The traditional method of manually determining the dental arch may soon be replaced by a robot to assist in generating a more individual dental arch. The system can be used to fabricate full dentures and bend orthodontic wires. Copyright © 2012 John Wiley & Sons, Ltd.

  6. A study on special test stand of automatic and manual descent control in presence of simulated g-load effect

    NASA Astrophysics Data System (ADS)

    Glazkov, Yury; Artjuchin, Yury; Astakhov, Alexander; Vas'kov, Alexander; Malyshev, Veniamin; Mitroshin, Edward; Glinsky, Valery; Moiseenko, Vasily; Makovlev, Vyacheslav

    The development of aircraft-type reusable space vehicles (RSV) involves the problem of complete compatibility of automatic, director and manual control. Task decision is complicated, in particular, due to considerable quantitative and qualitative changes of vehicle dynamic characteristics, little stability margins (and even of unstability) of the RSV, and stringent requirements to control accuracy at some flight phases. Besides, during control a pilot is affected by g-loads which hamper motor activity and deteriorate its accuracy, alter the functional status of the visual analyser, and influence higher nervous activity. A study of g-load effects on the control efficiency, especially in manual and director modes, is of primary importance. The main tools for study of a rational selection of manual and director vehicle control systems and as an aid in formulating recommendations for optimum crew-automatic control system interactions are special complex and functional flight simulator test stands. The proposed simulator stand includes a powerful digital computer complex combined with the control system of the centrifuge. The interior of a pilot's vehicle cabin is imitated. A situation image system, pyscho-physical monitoring system, physician, centrifuge operator, and instructor stations are linked with the test stand.

  7. 46 CFR 160.176-19 - Servicing.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... section contains requirements for servicing facilities, manuals, training, guidelines, and records. Other... follow the procedures in the service manual required by this section. (2) Each servicing facility must... strong sunlight, and have appropriate temperature and humidity control as specified in the service manual...

  8. A synchronized computational architecture for generalized bilateral control of robot arms

    NASA Technical Reports Server (NTRS)

    Bejczy, Antal K.; Szakaly, Zoltan

    1987-01-01

    This paper describes a computational architecture for an interconnected high speed distributed computing system for generalized bilateral control of robot arms. The key method of the architecture is the use of fully synchronized, interrupt driven software. Since an objective of the development is to utilize the processing resources efficiently, the synchronization is done in the hardware level to reduce system software overhead. The architecture also achieves a balaced load on the communication channel. The paper also describes some architectural relations to trading or sharing manual and automatic control.

  9. Adaptive automation of human-machine system information-processing functions.

    PubMed

    Kaber, David B; Wright, Melanie C; Prinzel, Lawrence J; Clamann, Michael P

    2005-01-01

    The goal of this research was to describe the ability of human operators to interact with adaptive automation (AA) applied to various stages of complex systems information processing, defined in a model of human-automation interaction. Forty participants operated a simulation of an air traffic control task. Automated assistance was adaptively applied to information acquisition, information analysis, decision making, and action implementation aspects of the task based on operator workload states, which were measured using a secondary task. The differential effects of the forms of automation were determined and compared with a manual control condition. Results of two 20-min trials of AA or manual control revealed a significant effect of the type of automation on performance, particularly during manual control periods as part of the adaptive conditions. Humans appear to better adapt to AA applied to sensory and psychomotor information-processing functions (action implementation) than to AA applied to cognitive functions (information analysis and decision making), and AA is superior to completely manual control. Potential applications of this research include the design of automation to support air traffic controller information processing.

  10. 18 CFR 3b.204 - Safeguarding information in manual and computer-based record systems.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... information in manual and computer-based record systems. 3b.204 Section 3b.204 Conservation of Power and Water... Collection of Records § 3b.204 Safeguarding information in manual and computer-based record systems. (a) The administrative and physical controls to protect the information in the manual and computer-based record systems...

  11. 18 CFR 3b.204 - Safeguarding information in manual and computer-based record systems.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... information in manual and computer-based record systems. 3b.204 Section 3b.204 Conservation of Power and Water... Collection of Records § 3b.204 Safeguarding information in manual and computer-based record systems. (a) The administrative and physical controls to protect the information in the manual and computer-based record systems...

  12. 18 CFR 3b.204 - Safeguarding information in manual and computer-based record systems.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... information in manual and computer-based record systems. 3b.204 Section 3b.204 Conservation of Power and Water... Collection of Records § 3b.204 Safeguarding information in manual and computer-based record systems. (a) The administrative and physical controls to protect the information in the manual and computer-based record systems...

  13. 18 CFR 3b.204 - Safeguarding information in manual and computer-based record systems.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... information in manual and computer-based record systems. 3b.204 Section 3b.204 Conservation of Power and Water... Collection of Records § 3b.204 Safeguarding information in manual and computer-based record systems. (a) The administrative and physical controls to protect the information in the manual and computer-based record systems...

  14. Fully Automatic Segmentation of Fluorescein Leakage in Subjects With Diabetic Macular Edema

    PubMed Central

    Rabbani, Hossein; Allingham, Michael J.; Mettu, Priyatham S.; Cousins, Scott W.; Farsiu, Sina

    2015-01-01

    Purpose. To create and validate software to automatically segment leakage area in real-world clinical fluorescein angiography (FA) images of subjects with diabetic macular edema (DME). Methods. Fluorescein angiography images obtained from 24 eyes of 24 subjects with DME were retrospectively analyzed. Both video and still-frame images were obtained using a Heidelberg Spectralis 6-mode HRA/OCT unit. We aligned early and late FA frames in the video by a two-step nonrigid registration method. To remove background artifacts, we subtracted early and late FA frames. Finally, after postprocessing steps, including detection and inpainting of the vessels, a robust active contour method was utilized to obtain leakage area in a 1500-μm-radius circular region centered at the fovea. Images were captured at different fields of view (FOVs) and were often contaminated with outliers, as is the case in real-world clinical imaging. Our algorithm was applied to these images with no manual input. Separately, all images were manually segmented by two retina specialists. The sensitivity, specificity, and accuracy of manual interobserver, manual intraobserver, and automatic methods were calculated. Results. The mean accuracy was 0.86 ± 0.08 for automatic versus manual, 0.83 ± 0.16 for manual interobserver, and 0.90 ± 0.08 for manual intraobserver segmentation methods. Conclusions. Our fully automated algorithm can reproducibly and accurately quantify the area of leakage of clinical-grade FA video and is congruent with expert manual segmentation. The performance was reliable for different DME subtypes. This approach has the potential to reduce time and labor costs and may yield objective and reproducible quantitative measurements of DME imaging biomarkers. PMID:25634978

  15. Manual versus Automated Carotid Artery Plaque Component Segmentation in High and Lower Quality 3.0 Tesla MRI Scans

    PubMed Central

    Smits, Loek P.; van Wijk, Diederik F.; Duivenvoorden, Raphael; Xu, Dongxiang; Yuan, Chun; Stroes, Erik S.; Nederveen, Aart J.

    2016-01-01

    Purpose To study the interscan reproducibility of manual versus automated segmentation of carotid artery plaque components, and the agreement between both methods, in high and lower quality MRI scans. Methods 24 patients with 30–70% carotid artery stenosis were planned for 3T carotid MRI, followed by a rescan within 1 month. A multicontrast protocol (T1w,T2w, PDw and TOF sequences) was used. After co-registration and delineation of the lumen and outer wall, segmentation of plaque components (lipid-rich necrotic cores (LRNC) and calcifications) was performed both manually and automated. Scan quality was assessed using a visual quality scale. Results Agreement for the detection of LRNC (Cohen’s kappa (k) is 0.04) and calcification (k = 0.41) between both manual and automated segmentation methods was poor. In the high-quality scans (visual quality score ≥ 3), the agreement between manual and automated segmentation increased to k = 0.55 and k = 0.58 for, respectively, the detection of LRNC and calcification larger than 1 mm2. Both manual and automated analysis showed good interscan reproducibility for the quantification of LRNC (intraclass correlation coefficient (ICC) of 0.94 and 0.80 respectively) and calcified plaque area (ICC of 0.95 and 0.77, respectively). Conclusion Agreement between manual and automated segmentation of LRNC and calcifications was poor, despite a good interscan reproducibility of both methods. The agreement between both methods increased to moderate in high quality scans. These findings indicate that image quality is a critical determinant of the performance of both manual and automated segmentation of carotid artery plaque components. PMID:27930665

  16. 40 CFR 53.2 - General requirements for a reference method determination.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ...) Manual methods—(1) Sulfur dioxide (SO 2 ) and lead. For measuring SO2 and lead, appendices A and G of part 50 of this chapter specify unique manual FRM for measuring these pollutants. Except as provided in § 53.16, other manual methods for SO2 and lead will not be considered for FRM determinations under this...

  17. Flight investigation of manual and automatic VTOL decelerating instrument approaches and landings

    NASA Technical Reports Server (NTRS)

    Kelly, J. R.; Niessen, F. R.; Thibodeaux, J. J.; Yenni, K. R.; Garren, J. F., Jr.

    1974-01-01

    A flight investigation was undertaken to study the problems associated with manual and automatic control of steep, decelerating instrument approaches and landings under simulated instrument conditions. The study was conducted with a research helicopter equipped with a three-cue flight-director indicator. The scope of the investigation included variations in the flight-director control laws, glide-path angle, deceleration profile, and control response characteristics. Investigation of the automatic-control problem resulted in the first automated approach and landing to a predetermined spot ever accomplished with a helicopter. Although well-controlled approaches and landings could be performed manually with the flight-director concept, pilot comments indicated the need for a better display which would more effectively integrate command and situation information.

  18. Validation of a Mobile Device for Acoustic Coordinated Reset Neuromodulation Tinnitus Therapy.

    PubMed

    Hauptmann, Christian; Wegener, Alexander; Poppe, Hendrik; Williams, Mark; Popelka, Gerald; Tass, Peter A

    2016-10-01

    Sound-based tinnitus intervention stimuli include broad-band noise signals with subjectively adjusted bandwidths used as maskers delivered by commercial devices or hearing aids, environmental sounds broadly described and delivered by both consumer devices and hearing aids, music recordings specifically modified and delivered in a variety of different ways, and other stimuli. Acoustic coordinated reset neuromodulation therapy for tinnitus reduction has unique and more stringent requirements compared to all other sound-based tinnitus interventions. These include precise characterization of tinnitus pitch and loudness, and effective provision of patient-controlled daily therapy signals at defined frequencies, levels, and durations outside of the clinic. The purpose of this study was to evaluate an approach to accommodate these requirements including evaluation of a mobile device, validation of an automated tinnitus pitch-matching algorithm and assessment of a patient's ability to control stimuli and collect repeated outcome measures. The experimental design involved direct laboratory measurements of the sound delivery capabilities of a mobile device, comparison of an automated, adaptive pitch-matching method to a traditional manual method and measures of a patient's ability to understand and manipulate a mobile device graphic user interface to both deliver the therapy signals and collect the outcome measures. This study consisted of 5 samples of a common mobile device for the laboratory measures and a total of 30 adult participants: 15 randomly selected normal-hearing participants with simulated tinnitus for validation of a tinnitus pitch-matching algorithm and 15 sequentially selected patients already undergoing tinnitus therapy for evaluation of patient usability. No tinnitus intervention(s) were specifically studied as a component of this study. Data collection involved laboratory measures of mobile devices, comparison of manual and automated adaptive tinnitus pitch-matching psychoacoustic procedures in the same participant analyzed for absolute differences (t test), variance differences (f test), and range comparisons, and assessment of patient usability including questionnaire measures and logs of patient observations. Mobile devices are able to reliably and accurately deliver the acoustic therapy signals. There was no difference in mean pitch matches (t test, p > 0.05) between an automated adaptive method compared to a traditional manual pitch-matching method. However, the variability of the automated pitch-matching method was much less (f test, p < 0.05) with twice as many matches within the predefined error range (±5%) compared to the manual pitch-matching method (80% versus 40%). After a short initial training, all participants were able to use the mobile device effectively and to perform the required tasks without further professional assistance. American Academy of Audiology

  19. ZAG-Otolith: Modification of Otolith-Ocular Reflexes, Motion Perception and Manual Control during Variable Radius Centrifugation Following Space Flight

    NASA Technical Reports Server (NTRS)

    Wood, S. J.; Clarke, A. H.; Rupert, A. H.; Harm, D. L.; Clement, G. R.

    2009-01-01

    Two joint ESA-NASA studies are examining changes in otolith-ocular reflexes and motion perception following short duration space flights, and the operational implications of post-flight tilt-translation ambiguity for manual control performance. Vibrotactile feedback of tilt orientation is also being evaluated as a countermeasure to improve performance during a closed-loop nulling task. METHODS. Data is currently being collected on astronaut subjects during 3 preflight sessions and during the first 8 days after Shuttle landings. Variable radius centrifugation is utilized to elicit otolith reflexes in the lateral plane without concordant roll canal cues. Unilateral centrifugation (400 deg/s, 3.5 cm radius) stimulates one otolith positioned off-axis while the opposite side is centered over the axis of rotation. During this paradigm, roll-tilt perception is measured using a subjective visual vertical task and ocular counter-rolling is obtained using binocular video-oculography. During a second paradigm (216 deg/s, <20 cm radius), the effects of stimulus frequency (0.15 - 0.6 Hz) are examined on eye movements and motion perception. A closed-loop nulling task is also performed with and without vibrotactile display feedback of chair radial position. PRELIMINARY RESULTS. Data collection is currently ongoing. Results to date suggest there is a trend for perceived tilt and translation amplitudes to be increased at the low and medium frequencies on landing day compared to pre-flight. Manual control performance is improved with vibrotactile feedback. DISCUSSION. One result of this study will be to characterize the variability (gain, asymmetry) in both otolithocular responses and motion perception during variable radius centrifugation, and measure the time course of postflight recovery. This study will also address how adaptive changes in otolith-mediated reflexes correspond to one's ability to perform closed-loop nulling tasks following G-transitions, and whether manual control performance can be improved with vibrotactile feedback of orientation.

  20. Association between heart rate variability and manual pulse rate.

    PubMed

    Hart, John

    2013-09-01

    One model for neurological assessment in chiropractic pertains to autonomic variability, tested commonly with heart rate variability (HRV). Since HRV may not be convenient to use on all patient visits, more user-friendly methods may help fill-in the gaps. Accordingly, this study tests the association between manual pulse rate and heart rate variability. The manual rates were also compared to the heart rate derived from HRV. Forty-eight chiropractic students were examined with heart rate variability (SDNN and mean heart rate) and two manual radial pulse rate measurements. Inclusion criteria consisted of participants being chiropractic students. Exclusion criteria for 46 of the participants consisted of a body mass index being greater than 30, age greater than 35, and history of: a) dizziness upon standing, b) treatment of psychiatric disorders, and c) diabetes. No exclusion criteria were applied to the remaining two participants who were also convenience sample volunteers. Linear associations between the manual pulse rate methods and the two heart rate variability measures (SDNN and mean heart) were tested with Pearson's correlation and simple linear regression. Moderate strength inverse (expected) correlations were observed between both manual pulse rate methods and SDNN (r = -0.640, 95% CI -0.781, -0.435; r = -0.632, 95% CI -0.776, -0.425). Strong direct (expected) relationships were observed between the manual pulse rate methods and heart rate derived from HRV technology (r = 0.934, 95% CI 0.885, 0.962; r = 0.941, 95% CI 0.897, 0.966). Manual pulse rates may be a useful option for assessing autonomic variability. Furthermore, this study showed a strong relationship between manual pulse rates and heart rate derived from HRV technology.

  1. Identification of spinal tissues loaded by manual therapy: a robot-based serial dissection technique applied in porcine motion segments.

    PubMed

    Kawchuk, Gregory N; Carrasco, Alejandro; Beecher, Grayson; Goertzen, Darrell; Prasad, Narasimha

    2010-10-15

    Serial dissection of porcine motion segments during robotic control of vertebral kinematics. To identify which spinal tissues are loaded in response to manual therapy (manipulation and mobilization) and to what magnitude. Various theoretical constructs attempt to explain how manual therapies load specific spinal tissues. By using a parallel robot to control vertebral kinematics during serial dissection, it is possible to quantify the loads experienced by discrete spinal tissues undergoing common therapeutic procedures such as manual therapy. In 9 porcine cadavers, manual therapy was provided to L3 and the kinematic response of L3-L4 recorded. The exact kinematic trajectory experienced by L3-L4 in response to manual therapy was then replayed to the isolated segment by a parallel robot equipped with a 6-axis load cell. Discrete spinal tissues were then removed and the kinematic pathway replayed. The change in forces and moments following tissue removal were considered to be those applied to that specific tissue by manual therapy. In this study, both manual therapies affected spinal tissues. The intervertebral disc experienced the greatest forces and moments arising from both manipulation and mobilization. This study is the first to identify which tissues are loaded in response to manual therapy. The observation that manual therapy loads some tissues to a much greater magnitude than others offers a possible explanation for its modest treatment effect; only conditions involving these tissues may be influenced by manual therapy. Future studies are planned to determine if manual therapy can be altered to target (or avoid) specific spinal tissues.

  2. Single-layer continuous suture contributes to the reduction of surgical complications in digestive tract anastomosis involving special anatomical locations.

    PubMed

    Li, Guo-Cai; Zhang, Yu-Chun; Xu, Yong; Zhang, Fang-Cheng; Huang, Wei-Hua; Xu, Jian-Qing; Ma, Qing-Jiu

    2014-01-01

    The key point of digestive cancer surgery is reconstruction and anastomosis of the digestive tract. Traditional anastomoses involve double-layer interrupted suturing, manually or using a surgical stapler. In special anatomical locations, however, suturing may become increasingly difficult and the complication rate increases accordingly. In this study, we aimed to investigate the feasibility and safety of a new manual suturing method, the single-layer continuous suture in the posterior wall of the anastomosis. Between January, 2007 and August, 2012, 101 patients with digestive cancer underwent surgery in Xi'an Gaoxin Hospital. Of those patients, 27 underwent surgery with the new manual method and the remaining 74 underwent surgery using traditional methods of anastomosis of the digestive tract. Surgical time, intraoperative blood loss, drainage duration, complications, blood tests, postoperative quality of life (QOL) and overall expenditure were recorded and analyzed. No significant differences were observed in surgical time, intraoperative blood loss, temperature, blood tests and postoperative QOL between the two groups. However, compared with the control group, the new manual suture group exhibited a lower surgical complication rate (7.40 vs. 31.08%; P=0.018), lower blood transfusion volume (274.07±419.33 vs. 646.67±1,146.06 ml; P=0.053), shorter postoperative hospital stay (14.60±4.19 vs. 17.60±6.29 days; P=0.038) and lower overall expenditure (3,509.85±768.68 vs. 6,141.83±308.90 renminbi; P=0.001). Our results suggested that single-layer continuous suturing for the anastomosis of the digestive tract is feasible and safe and may contribute to the reduction of surgical complications and overall expenditure.

  3. Single-layer continuous suture contributes to the reduction of surgical complications in digestive tract anastomosis involving special anatomical locations

    PubMed Central

    LI, GUO-CAI; ZHANG, YU-CHUN; XU, YONG; ZHANG, FANG-CHENG; HUANG, WEI-HUA; XU, JIAN-QING; MA, QING-JIU

    2014-01-01

    The key point of digestive cancer surgery is reconstruction and anastomosis of the digestive tract. Traditional anastomoses involve double-layer interrupted suturing, manually or using a surgical stapler. In special anatomical locations, however, suturing may become increasingly difficult and the complication rate increases accordingly. In this study, we aimed to investigate the feasibility and safety of a new manual suturing method, the single-layer continuous suture in the posterior wall of the anastomosis. Between January, 2007 and August, 2012, 101 patients with digestive cancer underwent surgery in Xi’an Gaoxin Hospital. Of those patients, 27 underwent surgery with the new manual method and the remaining 74 underwent surgery using traditional methods of anastomosis of the digestive tract. Surgical time, intraoperative blood loss, drainage duration, complications, blood tests, postoperative quality of life (QOL) and overall expenditure were recorded and analyzed. No significant differences were observed in surgical time, intraoperative blood loss, temperature, blood tests and postoperative QOL between the two groups. However, compared with the control group, the new manual suture group exhibited a lower surgical complication rate (7.40 vs. 31.08%; P=0.018), lower blood transfusion volume (274.07±419.33 vs. 646.67±1,146.06 ml; P=0.053), shorter postoperative hospital stay (14.60±4.19 vs. 17.60±6.29 days; P=0.038) and lower overall expenditure (3,509.85±768.68 vs. 6,141.83±308.90 renminbi; P=0.001). Our results suggested that single-layer continuous suturing for the anastomosis of the digestive tract is feasible and safe and may contribute to the reduction of surgical complications and overall expenditure. PMID:24649327

  4. Piloted Evaluation of the H-Mode, a Variable Autonomy Control System, in Motion-Based Simulation

    NASA Technical Reports Server (NTRS)

    Goodrich, Kenneth H.; Schutte, Paul C.; Williams, Ralph A.

    2008-01-01

    As aircraft become able to autonomously respond to a range of situations with performance surpassing human operators, we are compelled to look for new methods that help understand their use and guide the design of new, more effective forms of automation and interaction. The "H-mode" is one such method and is based on the metaphor of a well-trained horse. The concept allows the pilot to manage a broad range of control automation functionality, from augmented manual control to FMS-like coupling and automation initiated actions, using a common interface system and easily learned set of interaction skills. The interface leverages familiar manual control interfaces (e.g., the control stick) and flight displays through the addition of contextually dependent haptic-multimodal elements. The concept is relevant to manned and remotely piloted vehicles. This paper provides an overview of the H-mode concept followed by a presentation of the results from a recent evaluation conducted in a motion-based simulator. The evaluation focused on assessing the overall usability and flying qualities of the concept with an emphasis on the effects of turbulence and cockpit motion. Because the H-mode results in interactions between traditional flying qualities and management of higher-level flight path automation, these effects are of particular interest. The results indicate that the concept may provide a useful complement or replacement to conventional interfaces, and retains the usefulness in the presence of turbulence and motion.

  5. Computational Methods for Analyzing Health News Coverage

    ERIC Educational Resources Information Center

    McFarlane, Delano J.

    2011-01-01

    Researchers that investigate the media's coverage of health have historically relied on keyword searches to retrieve relevant health news coverage, and manual content analysis methods to categorize and score health news text. These methods are problematic. Manual content analysis methods are labor intensive, time consuming, and inherently…

  6. [A semimicroquality evaluation method on Panax notoginseng and its application in analysis of continuous cropping obstacles research samples].

    PubMed

    Cao, Yi; Wang, Chao-Qun; Xu, Feng; Jia, Xiu-Hong; Liu, Guang-Xue; Yang, Sheng-Chao; Long, Guang-Qiang; Chen, Zhong-Jian; Wei, Fu-Zhou; Yang, Shao-Zhou; Fukuda, Kozo; Wang, Xuan; Cai, Shao-Qing

    2016-10-01

    Panax notoginseng is a commonly used traditional Chinese medicine with blood activating effect while has continuous cropping obstacle problem in planting process. In present study, a semimicroextraction method with water-saturated n-butanol on 0.1 g notoginseng sample was established with good repeatability (RSD<2.5%) and 9.6%-20.6% higher extraction efficiency of seven saponins than the conventional method. A total of 16 characteristic peaks were identified by LC-MS-IT-TOF, including eight 20(S)-protopanaxatriol (PPT) type saponins and eight 20(S)-protopanaxadiol (PPD) type saponins. The established method was utilized to evaluate the quality of notoginseng samples cultivated by manual intervened methods to overcome continuous cropping obstacles.As a result, HPLC fingerprint similarity, content of Fa and ratio of notoginsenoside K and notoginsenoside Fa (N-K/Fa) were found out to be as valuatable markers of the quality of samples in continuous cropping obstacle research, of which N-K/Fa could also be applied to the analysis of notoginseng samples with different growth years.Notoginseng samples with continuous cropping obstacle had HPLC fingerprint similarity lower than 0.87, in consistent with normal sample, and had significant lower content of notoginsenoside Fa and significant higher N-K/Fa (2.35-4.74) than normal group (0.45-1.33). All samples in the first group with manual intervention showed high similarity with normal group (>0.87), similar content of common peaks and N-K/Fa (0.42-2.06). The content of notoginsenoside K in the second group with manual intervention was higher than normal group. All samples except two displayed similarity higher than 0.87 and possessed content of 16 saponins close to normal group. The result showed that notoginseng samples with continuous cropping obstacle had lower quality than normal sample. And manual intervened methods could improve their quality in different levels.The method established in this study was simple, fast and accurate, and the markers may provide new guides for quality control in continuous cropping obstacle research of notoginseng. Copyright© by the Chinese Pharmaceutical Association.

  7. Training Manual for Elements of Interface Definition and Control

    NASA Technical Reports Server (NTRS)

    Lalli, Vincent R. (Editor); Kastner, Robert E. (Editor); Hartt, Henry N. (Editor)

    1997-01-01

    The primary thrust of this manual is to ensure that the format and information needed to control interfaces between equipment are clear and understandable. The emphasis is on controlling the engineering design of the interface and not on the functional performance requirements of the system or the internal workings of the interfacing equipment. Interface control should take place, with rare exception, at the interfacing elements and no further. There are two essential sections of the manual. Chapter 2, Principles of Interface Control, discusses how interfaces are defined. It describes different types of interfaces to be considered and recommends a format for the documentation necessary for adequate interface control. Chapter 3, The Process: Through the Design Phases, provides tailored guidance for interface definition and control. This manual can be used to improve planned or existing interface control processes during system design and development. It can also be used to refresh and update the corporate knowledge base. The information presented herein will reduce the amount of paper and data required in interface definition and control processes by as much as 50 percent and will shorten the time required to prepare an interface control document. It also highlights the essential technical parameters that ensure that flight subsystems will indeed fit together and function as intended after assembly and checkout.

  8. Manuals Used in the National Aquatic Resource Surveys

    EPA Pesticide Factsheets

    Various manuals are used to communicate the methods and guidelines for the National Aquatic Resource Surveys. The Field Operations Manual: outlines the field protocols that crews will utilize to sample sites.

  9. PROCESS DESIGN MANUAL FOR SLUDGE TREATMENT AND DISPOSAL

    EPA Science Inventory

    The purpose of this manual is to provide the engineering community and related industry with a new source of information to be used in the planning, design, and operation of present and future wastewater pollution control facilities. This manual supplements this existing knowledg...

  10. An automatic vision-based malaria diagnosis system.

    PubMed

    Vink, J P; Laubscher, M; Vlutters, R; Silamut, K; Maude, R J; Hasan, M U; DE Haan, G

    2013-06-01

    Malaria is a worldwide health problem with 225 million infections each year. A fast and easy-to-use method, with high performance is required to differentiate malaria from non-malarial fevers. Manual examination of blood smears is currently the gold standard, but it is time-consuming, labour-intensive, requires skilled microscopists and the sensitivity of the method depends heavily on the skills of the microscopist. We propose an easy-to-use, quantitative cartridge-scanner system for vision-based malaria diagnosis, focusing on low malaria parasite densities. We have used special finger-prick cartridges filled with acridine orange to obtain a thin blood film and a dedicated scanner to image the cartridge. Using supervised learning, we have built a Plasmodium falciparum detector. A two-step approach was used to first segment potentially interesting areas, which are then analysed in more detail. The performance of the detector was validated using 5,420 manually annotated parasite images from malaria parasite culture in medium, as well as using 40 cartridges of 11,780 images containing healthy blood. From finger prick to result, the prototype cartridge-scanner system gave a quantitative diagnosis in 16 min, of which only 1 min required manual interaction of basic operations. It does not require a wet lab or a skilled operator and provides parasite images for manual review and quality control. In healthy samples, the image analysis part of the system achieved an overall specificity of 99.999978% at the level of (infected) red blood cells, resulting in at most seven false positives per microlitre. Furthermore, the system showed a sensitivity of 75% at the cell level, enabling the detection of low parasite densities in a fast and easy-to-use manner. A field trial in Chittagong (Bangladesh) indicated that future work should primarily focus on improving the filling process of the cartridge and the focus control part of the scanner. © 2013 The Authors Journal of Microscopy © 2013 Royal Microscopical Society.

  11. Urinalysis: The Automated Versus Manual Techniques; Is It Time To Change?.

    PubMed

    Ahmed, Asmaa Ismail; Baz, Heba; Lotfy, Sarah

    2016-01-01

    Urinalysis is the third major test in clinical laboratory. Manual technique imprecision urges the need for a rapid reliable automated test. We evaluated the H800-FUSIOO automatic urine sediment analyzer and compared it to the manual urinalysis technique to determine if it may be a competitive substitute in laboratories of central hospitals. 1000 urine samples were examined by the two methods in parallel. Agreement, precision, carryover, drift, sensitivity, specificity, and practicability criteria were tested. Agreement ranged from excellent to good for all urine semi-quantitative components (K > 0.4, p = 0.000), except for granular casts (K = 0.317, p = 0.000). Specific gravity results correlated well between the two methods (r = 0.884, p = 0.000). RBCS and WBCs showed moderate correlation (r = 0.42, p = 0.000) and (r = 0.44, p = 0.000), respectively. The auto-analyzer's within-run precision was > 75% for all semi-quantitative components except for proteins (50% precision). This finding in addition to the granular casts poor agreement indicate the necessity of operator interference at the critical cutoff values. As regards quantitative contents, RBCs showed a mean of 69.8 +/- 3.95, C.V. = 5.7, WBCs showed a mean of 38.9 +/- 1.9, C.V. = 4.9). Specific gravity, pH, microalbumin, and creatinine also showed good precision results with C.Vs of 0.000, 2.6, 9.1, and 0.00 respectively. In the between run precision, positive control showed good precision (C.V. = 2.9), while negative control's C.V. was strikingly high (C.V. = 127). Carryover and drift studies were satisfactory. Manual examination of inter-observer results showed major discrepancies (< 60% similar readings), while intra-observer's results correlated well with each other (r = 0.99, p = 0.000). Automation of urinalysis decreases observer-associated variation and offers prompt competitive results when standardized for screening away from the borderline cutoffs.

  12. Heavily Oiled Salt Marsh following the Deepwater Horizon Oil Spill, Ecological Comparisons of Shoreline Cleanup Treatments and Recovery

    PubMed Central

    Zengel, Scott; Bernik, Brittany M.; Rutherford, Nicolle; Nixon, Zachary; Michel, Jacqueline

    2015-01-01

    The Deepwater Horizon oil spill affected hundreds of kilometers of coastal wetland shorelines, including salt marshes with persistent heavy oiling that required intensive shoreline “cleanup” treatment. Oiled marsh treatment involves a delicate balance among: removing oil, speeding the degradation of remaining oil, protecting wildlife, fostering habitat recovery, and not causing further ecological damage with treatment. To examine the effectiveness and ecological effects of treatment during the emergency response, oiling characteristics and ecological parameters were compared over two years among heavily oiled test plots subject to: manual treatment, mechanical treatment, natural recovery (no treatment, oiled control), as well as adjacent reference conditions. An additional experiment compared areas with and without vegetation planting following treatment. Negative effects of persistent heavy oiling on marsh vegetation, intertidal invertebrates, and shoreline erosion were observed. In areas without treatment, oiling conditions and negative effects for most marsh parameters did not considerably improve over two years. Both manual and mechanical treatment were effective at improving oiling conditions and vegetation characteristics, beginning the recovery process, though recovery was not complete by two years. Mechanical treatment had additional negative effects of mixing oil into the marsh soils and further accelerating erosion. Manual treatment appeared to strike the right balance between improving oiling and habitat conditions while not causing additional detrimental effects. However, even with these improvements, marsh periwinkle snails showed minimal signs of recovery through two years, suggesting that some ecosystem components may lag vegetation recovery. Planting following treatment quickened vegetation recovery and reduced shoreline erosion. Faced with comparable marsh oiling in the future, we would recommend manual treatment followed by planting. We caution against the use of intensive treatment methods with lesser marsh oiling. Oiled controls (no treatment “set-asides”) are essential for judging marsh treatment effectiveness and ecological effects; we recommend their use when applying intensive treatment methods. PMID:26200349

  13. [Comparison of manual and automated (MagNA Pure) nucleic acid isolation methods in molecular diagnosis of HIV infections].

    PubMed

    Alp, Alpaslan; Us, Dürdal; Hasçelik, Gülşen

    2004-01-01

    Rapid quantitative molecular methods are very important for the diagnosis of human immunodeficiency virus (HIV) infections, assessment of prognosis and follow up. The purpose of this study was to compare and evaluate the performances of conventional manual extraction method and automated MagNA Pure system, for the nucleic acid isolation step which is the first and most important step in molecular diagnosis of HIV infections. Plasma samples of 35 patients in which anti-HIV antibodies were found as positive by microparticule enzyme immunoassay and confirmed by immunoblotting method, were included in the study. The nucleic acids obtained simultaneously by manual isolation kit (Cobas Amplicor, HIV-1 Monitor Test, version 1.5, Roche Diagnostics) and automated system (MagNA Pure LC Total Nucleic Acid Isolation Kit, Roche Diagnostics), were amplified and detected in Cobas Amplicor (Roche Diagnostics) instrument. Twenty three of 35 samples (65.7%) were found to be positive, and 9 (25.7%) were negative by both of the methods. The agreement between the methods were detected as 91.4%, for qualitative results. Viral RNA copies detected by manual and MagNA Pure isolation methods were found between 76.0-7.590.000 (mean: 487.143) and 113.0-20.300.0000 (mean: 2.174.097) copies/ml, respectively. When both of the overall and individual results were evaluated, the number of RNA copies obtained with automatized system, were found higher than the manual method (p<0.05). Three samples which had low numbers of nucleic acids (113, 773, 857, respectively) with MagNA Pure, yielded negative results with manual method. In conclusion, the automatized MagNA Pure system was found to be a reliable, rapid and practical method for the isolation of HIV-RNA.

  14. A motor learning approach to training wheelchair propulsion biomechanics for new manual wheelchair users: A pilot study

    PubMed Central

    Morgan, Kerri A.; Tucker, Susan M.; Klaesner, Joseph W.; Engsberg, Jack R.

    2017-01-01

    Context/Objective Developing an evidence-based approach to teaching wheelchair skills and proper propulsion for everyday wheelchair users with a spinal cord injury (SCI) is important to their rehabilitation. The purpose of this project was to pilot test manual wheelchair training based on motor learning and repetition-based approaches for new manual wheelchair users with an SCI. Design A repeated measures within-subject design was used with participants acting as their own controls. Methods Six persons with an SCI requiring the use of a manual wheelchair participated in wheelchair training. The training included nine 90-minute sessions. The primary focus was on wheelchair propulsion biomechanics with a secondary focus on wheelchair skills. Outcome Measures During Pretest 1, Pretest 2, and Posttest, wheelchair propulsion biomechanics were measured using the Wheelchair Propulsion Test and a Video Motion Capture system. During Pretest 2 and Posttest, propulsion forces using the WheelMill System and wheelchair skills using the Wheelchair Skills Test were measured. Results Significant changes in area of the push loop, hand-to-axle relationship, and slope of push forces were found. Changes in propulsion patterns were identified post-training. No significant differences were found in peak and average push forces and wheelchair skills pre- and post-training. Conclusions This project identified trends in change related to a repetition-based motor learning approach for propelling a manual wheelchair. The changes found were related to the propulsion patterns used by participants. Despite some challenges associated with implementing interventions for new manual wheelchair users, such as recruitment, the results of this study show that repetition-based training can improve biomechanics and propulsion patterns for new manual wheelchair users. PMID:26674751

  15. Methicillin-resistant Staphylococcus aureus: an overview for manual therapists().

    PubMed

    Green, Bart N; Johnson, Claire D; Egan, Jonathon Todd; Rosenthal, Michael; Griffith, Erin A; Evans, Marion Willard

    2012-03-01

    Methicillin-resistant Staphylococcus aureus (MRSA) is associated with difficult-to-treat infections and high levels of morbidity. Manual practitioners work in environments where MRSA is a common acquired infection. The purpose of this review is to provide a practical overview of MRSA as it applies to the manual therapy professions (eg, physical and occupational therapy, athletic training, chiropractic, osteopathy, massage, sports medicine) and to discuss how to identify and prevent MRSA infections in manual therapy work environments. PubMed and CINAHL were searched from the beginning of their respective indexing years through June 2011 using the search terms MRSA, methicillin-resistant Staphylococcus aureus, and Staphylococcus aureus. Texts and authoritative Web sites were also reviewed. Pertinent articles from the authors' libraries were included if they were not already identified in the literature search. Articles were included if they were applicable to ambulatory health care environments in which manual therapists work or if the content of the article related to the clinical management of MRSA. Following information extraction, 95 citations were included in this review, to include 76 peer-reviewed journal articles, 16 government Web sites, and 3 textbooks. Information was organized into 10 clinically relevant categories for presentation. Information was organized into the following clinically relevant categories: microbiology, development of MRSA, risk factors for infection, clinical presentation, diagnostic tests, screening tests, reporting, treatment, prevention for patients and athletes, and prevention for health care workers. Methicillin-resistant S aureus is a health risk in the community and to patients and athletes treated by manual therapists. Manual practitioners can play an essential role in recognizing MRSA infections and helping to control its transmission in the health care environment and the community. Essential methods for protecting patients and health care workers include being aware of presenting signs, patient education, and using appropriate hand and clinic hygiene.

  16. Comparison of cell counting methods in rodent pulmonary toxicity studies: automated and manual protocols and considerations for experimental design

    PubMed Central

    Zeidler-Erdely, Patti C.; Antonini, James M.; Meighan, Terence G.; Young, Shih-Houng; Eye, Tracy J.; Hammer, Mary Ann; Erdely, Aaron

    2016-01-01

    Pulmonary toxicity studies often use bronchoalveolar lavage (BAL) to investigate potential adverse lung responses to a particulate exposure. The BAL cellular fraction is counted, using automated (i.e. Coulter Counter®), flow cytometry or manual (i.e. hemocytometer) methods, to determine inflammatory cell influx. The goal of the study was to compare the different counting methods to determine which is optimal for examining BAL cell influx after exposure by inhalation or intratracheal instillation (ITI) to different particles with varying inherent pulmonary toxicities in both rat and mouse models. General findings indicate that total BAL cell counts using the automated and manual methods tended to agree after inhalation or ITI exposure to particle samples that are relatively nontoxic or at later time points after exposure to a pneumotoxic particle when the response resolves. However, when the initial lung inflammation and cytotoxicity was high after exposure to a pneumotoxic particle, significant differences were observed when comparing cell counts from the automated, flow cytometry and manual methods. When using total BAL cell count for differential calculations from the automated method, depending on the cell diameter size range cutoff, the data suggest that the number of lung polymorphonuclear leukocytes (PMN) varies. Importantly, the automated counts, regardless of the size cutoff, still indicated a greater number of total lung PMN when compared with the manual method, which agreed more closely with flow cytometry. The results suggest that either the manual method or flow cytometry would be better suited for BAL studies where cytotoxicity is an unknown variable. PMID:27251196

  17. Development of representative magnetic resonance imaging-based atlases of the canine brain and evaluation of three methods for atlas-based segmentation.

    PubMed

    Milne, Marjorie E; Steward, Christopher; Firestone, Simon M; Long, Sam N; O'Brien, Terrence J; Moffat, Bradford A

    2016-04-01

    To develop representative MRI atlases of the canine brain and to evaluate 3 methods of atlas-based segmentation (ABS). 62 dogs without clinical signs of epilepsy and without MRI evidence of structural brain disease. The MRI scans from 44 dogs were used to develop 4 templates on the basis of brain shape (brachycephalic, mesaticephalic, dolichocephalic, and combined mesaticephalic and dolichocephalic). Atlas labels were generated by segmenting the brain, ventricular system, hippocampal formation, and caudate nuclei. The MRI scans from the remaining 18 dogs were used to evaluate 3 methods of ABS (manual brain extraction and application of a brain shape-specific template [A], automatic brain extraction and application of a brain shape-specific template [B], and manual brain extraction and application of a combined template [C]). The performance of each ABS method was compared by calculation of the Dice and Jaccard coefficients, with manual segmentation used as the gold standard. Method A had the highest mean Jaccard coefficient and was the most accurate ABS method assessed. Measures of overlap for ABS methods that used manual brain extraction (A and C) ranged from 0.75 to 0.95 and compared favorably with repeated measures of overlap for manual extraction, which ranged from 0.88 to 0.97. Atlas-based segmentation was an accurate and repeatable method for segmentation of canine brain structures. It could be performed more rapidly than manual segmentation, which should allow the application of computer-assisted volumetry to large data sets and clinical cases and facilitate neuroimaging research and disease diagnosis.

  18. Comparison of cell counting methods in rodent pulmonary toxicity studies: automated and manual protocols and considerations for experimental design.

    PubMed

    Zeidler-Erdely, Patti C; Antonini, James M; Meighan, Terence G; Young, Shih-Houng; Eye, Tracy J; Hammer, Mary Ann; Erdely, Aaron

    2016-08-01

    Pulmonary toxicity studies often use bronchoalveolar lavage (BAL) to investigate potential adverse lung responses to a particulate exposure. The BAL cellular fraction is counted, using automated (i.e. Coulter Counter®), flow cytometry or manual (i.e. hemocytometer) methods, to determine inflammatory cell influx. The goal of the study was to compare the different counting methods to determine which is optimal for examining BAL cell influx after exposure by inhalation or intratracheal instillation (ITI) to different particles with varying inherent pulmonary toxicities in both rat and mouse models. General findings indicate that total BAL cell counts using the automated and manual methods tended to agree after inhalation or ITI exposure to particle samples that are relatively nontoxic or at later time points after exposure to a pneumotoxic particle when the response resolves. However, when the initial lung inflammation and cytotoxicity was high after exposure to a pneumotoxic particle, significant differences were observed when comparing cell counts from the automated, flow cytometry and manual methods. When using total BAL cell count for differential calculations from the automated method, depending on the cell diameter size range cutoff, the data suggest that the number of lung polymorphonuclear leukocytes (PMN) varies. Importantly, the automated counts, regardless of the size cutoff, still indicated a greater number of total lung PMN when compared with the manual method, which agreed more closely with flow cytometry. The results suggest that either the manual method or flow cytometry would be better suited for BAL studies where cytotoxicity is an unknown variable.

  19. Field of dreamers and dreamed-up fields: functional and fake perimetry.

    PubMed

    Thompson, J C; Kosmorsky, G S; Ellis, B D

    1996-01-01

    Hysterical and malingering patients can manifest visual field defects on perimetry (visual field testing), including defects suggestive of true visual pathway pathology. It has been shown that control subjects can easily imitate some pathologic defects with automated, computed perimetry. The authors sought to determine whether subjects could imitate the same pathologic defect with manual and automated perimetry. Six subjects posed as patients with neurologic problems. They had manual perimetry with both an experienced and inexperienced technician followed by automated perimetry. They were later interviewed about the methods of the technicians and the difficulty of the exercise. Four of six subjects easily imitated the assigned defects with both technicians on manual perimetry and with automated perimetry. These included quadrantic, altitudinal, hemianopic, and enlarged blind-spot defects. Two subjects who were assigned cecocentral and paracentral scotomas instead produced enlarged blind spots by manual perimetry and defects suggestive of chiasmal pathology by automated perimetry. Paradoxically, some subjects found that experienced technicians were easier to fool than inexperienced technicians because of the systematic way in which experienced technicians defined defects. With minimal coaching, some subjects can imitate visual fields with enlarged blind spots, quadrantic, hemianopic, and altitudinal defects with ease and reproducibility by both automated and manual perimetry. Cecocentral and paracentral scotomas are harder to imitate but may be mistaken as representing chiasmal pathology. Paradoxically, experienced technicians may not be better at detecting hysterical or malingering individuals.

  20. Ohio manual of uniform traffic control devices [2003

    DOT National Transportation Integrated Search

    2003-01-01

    The purpose of traffic control device and warrants for their use is to help to insure highway safety by providing for the orderly and predictable movement of all traffic and to provide such guidance and warnings as are needed. This manual sets forth ...

  1. Process Design Manual for Nitrogen Control.

    ERIC Educational Resources Information Center

    Parker, Denny S.; And Others

    This manual presents theoretical and process design criteria for the implementation of nitrogen control technology in municipal wastewater treatment facilities. Design concepts are emphasized through examination of data from full-scale and pilot installations. Design data are included on biological nitrification and denitrification, breakpoint…

  2. Termite Pest Control - Industrial. Manual 96.

    ERIC Educational Resources Information Center

    Missouri Univ., Columbia. Agricultural Experiment Station.

    This training manual provides information needed to meet the minimum EPA standards for certification as a commercial applicator of pesticides in the termite pest control category. The text discusses general pests, especially ants, and wood-destroying organisms such as termites, beetles, and fungi. (CS)

  3. Public Health Pest Control Category Manual.

    ERIC Educational Resources Information Center

    Bowman, James S.; Turmel, Jon P.

    This manual provides information needed to meet the standards for pesticide applicator certification. It presents pest control guidelines for those organisms of public health significance. Fact sheets with line drawings discuss pests such as cockroaches, bedbugs, lice, ants, beetles, bats, birds, and rodents. (CS)

  4. Myocardial infarct sizing by late gadolinium-enhanced MRI: Comparison of manual, full-width at half-maximum, and n-standard deviation methods.

    PubMed

    Zhang, Lin; Huttin, Olivier; Marie, Pierre-Yves; Felblinger, Jacques; Beaumont, Marine; Chillou, Christian DE; Girerd, Nicolas; Mandry, Damien

    2016-11-01

    To compare three widely used methods for myocardial infarct (MI) sizing on late gadolinium-enhanced (LGE) magnetic resonance (MR) images: manual delineation and two semiautomated techniques (full-width at half-maximum [FWHM] and n-standard deviation [SD]). 3T phase-sensitive inversion-recovery (PSIR) LGE images of 114 patients after an acute MI (2-4 days and 6 months) were analyzed by two independent observers to determine both total and core infarct sizes (TIS/CIS). Manual delineation served as the reference for determination of optimal thresholds for semiautomated methods after thresholding at multiple values. Reproducibility and accuracy were expressed as overall bias ± 95% limits of agreement. Mean infarct sizes by manual methods were 39.0%/24.4% for the acute MI group (TIS/CIS) and 29.7%/17.3% for the chronic MI group. The optimal thresholds (ie, providing the closest mean value to the manual method) were FWHM30% and 3SD for the TIS measurement and FWHM45% and 6SD for the CIS measurement (paired t-test; all P > 0.05). The best reproducibility was obtained using FWHM. For TIS measurement in the acute MI group, intra-/interobserver agreements, from Bland-Altman analysis, with FWHM30%, 3SD, and manual were -0.02 ± 7.74%/-0.74 ± 5.52%, 0.31 ± 9.78%/2.96 ± 16.62% and -2.12 ± 8.86%/0.18 ± 16.12, respectively; in the chronic MI group, the corresponding values were 0.23 ± 3.5%/-2.28 ± 15.06, -0.29 ± 10.46%/3.12 ± 13.06% and 1.68 ± 6.52%/-2.88 ± 9.62%, respectively. A similar trend for reproducibility was obtained for CIS measurement. However, semiautomated methods produced inconsistent results (variabilities of 24-46%) compared to manual delineation. The FWHM technique was the most reproducible method for infarct sizing both in acute and chronic MI. However, both FWHM and n-SD methods showed limited accuracy compared to manual delineation. J. Magn. Reson. Imaging 2016;44:1206-1217. © 2016 International Society for Magnetic Resonance in Medicine.

  5. Phantom Study Investigating the Accuracy of Manual and Automatic Image Fusion with the GE Logiq E9: Implications for use in Percutaneous Liver Interventions

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Burgmans, Mark Christiaan, E-mail: m.c.burgmans@lumc.nl; Harder, J. Michiel den, E-mail: chiel.den.harder@gmail.com; Meershoek, Philippa, E-mail: P.Meershoek@lumc.nl

    PurposeTo determine the accuracy of automatic and manual co-registration methods for image fusion of three-dimensional computed tomography (CT) with real-time ultrasonography (US) for image-guided liver interventions.Materials and MethodsCT images of a skills phantom with liver lesions were acquired and co-registered to US using GE Logiq E9 navigation software. Manual co-registration was compared to automatic and semiautomatic co-registration using an active tracker. Also, manual point registration was compared to plane registration with and without an additional translation point. Finally, comparison was made between manual and automatic selection of reference points. In each experiment, accuracy of the co-registration method was determined bymore » measurement of the residual displacement in phantom lesions by two independent observers.ResultsMean displacements for a superficial and deep liver lesion were comparable after manual and semiautomatic co-registration: 2.4 and 2.0 mm versus 2.0 and 2.5 mm, respectively. Both methods were significantly better than automatic co-registration: 5.9 and 5.2 mm residual displacement (p < 0.001; p < 0.01). The accuracy of manual point registration was higher than that of plane registration, the latter being heavily dependent on accurate matching of axial CT and US images by the operator. Automatic reference point selection resulted in significantly lower registration accuracy compared to manual point selection despite lower root-mean-square deviation (RMSD) values.ConclusionThe accuracy of manual and semiautomatic co-registration is better than that of automatic co-registration. For manual co-registration using a plane, choosing the correct plane orientation is an essential first step in the registration process. Automatic reference point selection based on RMSD values is error-prone.« less

  6. An adaptive human response mechanism controlling the V/STOL aircraft. Appendix 3: The adaptive control model of a pilot in V/STOL aircraft control loops. M.S. Thesis. Final Report

    NASA Technical Reports Server (NTRS)

    Kucuk, Senol

    1988-01-01

    Importance of the role of human operator in control systems has led to the particular area of manual control theory. Human describing functions were developed to model human behavior for manual control studies to take advantage of the successful and safe human operations. A single variable approach is presented that can be extended for multi-variable tasks where a low order human response model is used together with its rules, to adapt the model on-line, being capable of responding to the changes in the controlled element dynamics. Basic control theory concepts are used to combine the model, constrained with the physical observations, particularly, for the case of aircraft control. Pilot experience is represented as the initial model parameters. An adaptive root-locus method is presented as the adaptation law of the model where the closed loop bandwidth of the system is to be preserved in a stable manner with the adjustments of the pilot handling qualities which relate the latter to the closed loop bandwidth and damping of the closed loop pilot aircraft combination. A Kalman filter parameter estimator is presented as the controlled element identifier of the adaptive model where any discrepancies of the open loop dynamics from the presented one, are sensed to be compensated.

  7. Development of a Facility Management and Improvement Manual for Army Service Schools.

    DTIC Science & Technology

    1983-03-01

    Ehhhhomhmhhhhlo EEEEEEEohhhhhI L-Ii Ilk . ~MICROCOPY RESOLUTION TEST CHART NATIONAL BURESU Of STA OSN-T63-A NA01BRA FSADRS16- construction m*nilhlli 8mbtg 10b...U.S. Army Construction Engineering Research Lab. P.O. Box 4005 • 4A762731AT41-A-001 Champaign, IL 61820 _ It. CONTROLLING OFFICtNAME AND ADDRESS 37...developing a data collection and analysis method. The prototype method was discussed in CERL Interim Report P-ill. 3 This prototype method was tested by

  8. 33 CFR 385.3 - Definitions.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... performance of the Central and Southern Project and other water management systems in the South Florida... locations and times. Natural system means all land and water managed by the Federal government or the State... System Operating Manual and Project Operating Manuals. Operating Manuals contain water control plans...

  9. 33 CFR 385.3 - Definitions.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... performance of the Central and Southern Project and other water management systems in the South Florida... locations and times. Natural system means all land and water managed by the Federal government or the State... System Operating Manual and Project Operating Manuals. Operating Manuals contain water control plans...

  10. Motor Development: Manual of Alternative Procedures.

    ERIC Educational Resources Information Center

    McCormack, James E.

    The manual of alternative procedures for teaching handicapped children focuses on programming, planning, and implementing training in the gross motor (posture, limb control, locomotion) and fine motor (facial, digital) skills. The manual consists of the following sections: specific teaching tactics commonly used in motor training stiuations…

  11. Safe, Effective Use of Pesticides, A Manual for Commercial Applicators: Fruit Pest Control.

    ERIC Educational Resources Information Center

    Brunner, J.; And Others

    This manual is intended to assist pesticide applicators prepare for certification under the Michigan Pesticide Control Act of 1976. The primary focus of this publication is on fruit pest control. Sections included are: (1) Causes of fruit diseases; (2) Fruit fungicides and bactericides; (3) Insect and mite pests; (4) Insecticides and miticides;…

  12. Safe, Effective Use of Pesticides, A Manual for Commercial Applicators: Public Health Pest Control.

    ERIC Educational Resources Information Center

    Extension Service (USDA), Washington, DC.

    This manual is designed to assist public health pest control officials in meeting the certification required under the Michigan Pesticide Control Act of 1976. The four sections included describe: (1) Insects of public health significance in Michigan; (2) Other arthropods that affect man; (3) Swimmers' itch parasite and snail host; and (4)…

  13. Domestic Rodent Control Training Manual: A Training Aid for the Rodent Control Category for Certification of Pesticide Applicators.

    ERIC Educational Resources Information Center

    Childress, William R., Jr.; And Others

    This training manual, designed for training applicants who wish to obtain certification in pesticide application relative to rodent control, covers the following topics: economic factors, public health factors, biological characteristics of domestic rodents, rat and mouse signs, trapping, repellents, poisons, baits, poisoned water, dumps, sewers,…

  14. SRM Manual, Selected Resource Materials: Description and Evaluation.

    ERIC Educational Resources Information Center

    Alberta Dept. of Education, Edmonton. Special Educational Services Branch.

    Provided in the manual is descriptive and evaluative information on 67 instructional materials or programs frequently used with exceptional children in Alberta schools. A flow chart describes the three methods of using the manual: l) to obtain descriptive and evaluative information of an instruction program in the manual 2) to classify and record…

  15. Sharing control with haptics: seamless driver support from manual to automatic control.

    PubMed

    Mulder, Mark; Abbink, David A; Boer, Erwin R

    2012-10-01

    Haptic shared control was investigated as a human-machine interface that can intuitively share control between drivers and an automatic controller for curve negotiation. As long as automation systems are not fully reliable, a role remains for the driver to be vigilant to the system and the environment to catch any automation errors. The conventional binary switches between supervisory and manual control has many known issues, and haptic shared control is a promising alternative. A total of 42 respondents of varying age and driving experience participated in a driving experiment in a fixed-base simulator, in which curve negotiation behavior during shared control was compared to during manual control, as well as to three haptic tunings of an automatic controller without driver intervention. Under the experimental conditions studied, the main beneficial effect of haptic shared control compared to manual control was that less control activity (16% in steering wheel reversal rate, 15% in standard deviation of steering wheel angle) was needed for realizing an improved safety performance (e.g., 11% in peak lateral error). Full automation removed the need for any human control activity and improved safety performance (e.g., 35% in peak lateral error) but put the human in a supervisory position. Haptic shared control kept the driver in the loop, with enhanced performance at reduced control activity, mitigating the known issues that plague full automation. Haptic support for vehicular control ultimately seeks to intuitively combine human intelligence and creativity with the benefits of automation systems.

  16. Design manual: Oxygen Thermal Test Article (OTTA)

    NASA Technical Reports Server (NTRS)

    Chronic, W. L.; Baese, C. L.; Conder, R. L.

    1974-01-01

    The characteristics of a cryogenic tank for storing liquid hydrogen, nitrogen, oxygen, methane, or helium for an extended period of time with minimum losses are discussed. A description of the tank and control module, assembly drawings and details of major subassemblies, specific requirements controlling development of the system, thermal concept considerations, thermal analysis methods, and a record of test results are provided. The oxygen thermal test article thermal protection system has proven that the insulation system for cryogenic vessels is effective.

  17. Calibration of a semi-automated segmenting method for quantification of adipose tissue compartments from magnetic resonance images of mice.

    PubMed

    Garteiser, Philippe; Doblas, Sabrina; Towner, Rheal A; Griffin, Timothy M

    2013-11-01

    To use an automated water-suppressed magnetic resonance imaging (MRI) method to objectively assess adipose tissue (AT) volumes in whole body and specific regional body components (subcutaneous, thoracic and peritoneal) of obese and lean mice. Water-suppressed MR images were obtained on a 7T, horizontal-bore MRI system in whole bodies (excluding head) of 26 week old male C57BL6J mice fed a control (10% kcal fat) or high-fat diet (60% kcal fat) for 20 weeks. Manual (outlined regions) versus automated (Gaussian fitting applied to threshold-weighted images) segmentation procedures were compared for whole body AT and regional AT volumes (i.e., subcutaneous, thoracic, and peritoneal). The AT automated segmentation method was compared to dual-energy X-ray (DXA) analysis. The average AT volumes for whole body and individual compartments correlated well between the manual outlining and the automated methods (R2>0.77, p<0.05). Subcutaneous, peritoneal, and total body AT volumes were increased 2-3 fold and thoracic AT volume increased more than 5-fold in diet-induced obese mice versus controls (p<0.05). MRI and DXA-based method comparisons were highly correlative (R2=0.94, p<0.0001). Automated AT segmentation of water-suppressed MRI data using a global Gaussian filtering algorithm resulted in a fairly accurate assessment of total and regional AT volumes in a pre-clinical mouse model of obesity. © 2013 Elsevier Inc. All rights reserved.

  18. [Manual therapy in general practice].

    PubMed

    Березуцкий, Владимир И

    2016-01-01

    The article is devoted to manual therapy practice for diagnostics and treatment of vertebrogenic pain syndrome in general practice. Analytical roundup of sources proves medical advantage of implementation of manual therapy basic methods by general practice specialists.

  19. Six degree of freedom manual controls study report

    NASA Technical Reports Server (NTRS)

    Mckinnon, G. M.; Lippay, A.; King, M. L.

    1982-01-01

    The feasibility of using degree of freedom manual controls in space in an on orbit environment was determined. Several six degree of freedom controls were tested in a laboratory environment, and replica controls were used to control robot arms. The selection of six degrees of freedom as a design goal was based on the fact that six degrees are sufficient to define the location and orientation of a rigid body in space.

  20. Application of the 3D slicer chest imaging platform segmentation algorithm for large lung nodule delineation

    PubMed Central

    Parmar, Chintan; Blezek, Daniel; Estepar, Raul San Jose; Pieper, Steve; Kim, John; Aerts, Hugo J. W. L.

    2017-01-01

    Purpose Accurate segmentation of lung nodules is crucial in the development of imaging biomarkers for predicting malignancy of the nodules. Manual segmentation is time consuming and affected by inter-observer variability. We evaluated the robustness and accuracy of a publically available semiautomatic segmentation algorithm that is implemented in the 3D Slicer Chest Imaging Platform (CIP) and compared it with the performance of manual segmentation. Methods CT images of 354 manually segmented nodules were downloaded from the LIDC database. Four radiologists performed the manual segmentation and assessed various nodule characteristics. The semiautomatic CIP segmentation was initialized using the centroid of the manual segmentations, thereby generating four contours for each nodule. The robustness of both segmentation methods was assessed using the region of uncertainty (δ) and Dice similarity index (DSI). The robustness of the segmentation methods was compared using the Wilcoxon-signed rank test (pWilcoxon<0.05). The Dice similarity index (DSIAgree) between the manual and CIP segmentations was computed to estimate the accuracy of the semiautomatic contours. Results The median computational time of the CIP segmentation was 10 s. The median CIP and manually segmented volumes were 477 ml and 309 ml, respectively. CIP segmentations were significantly more robust than manual segmentations (median δCIP = 14ml, median dsiCIP = 99% vs. median δmanual = 222ml, median dsimanual = 82%) with pWilcoxon~10−16. The agreement between CIP and manual segmentations had a median DSIAgree of 60%. While 13% (47/354) of the nodules did not require any manual adjustment, minor to substantial manual adjustments were needed for 87% (305/354) of the nodules. CIP segmentations were observed to perform poorly (median DSIAgree≈50%) for non-/sub-solid nodules with subtle appearances and poorly defined boundaries. Conclusion Semi-automatic CIP segmentation can potentially reduce the physician workload for 13% of nodules owing to its computational efficiency and superior stability compared to manual segmentation. Although manual adjustment is needed for many cases, CIP segmentation provides a preliminary contour for physicians as a starting point. PMID:28594880

  1. Acupuncture for functional dyspepsia.

    PubMed

    Lan, Lei; Zeng, Fang; Liu, Guan J; Ying, Li; Wu, Xi; Liu, Mailan; Liang, Fan-Rong

    2014-10-13

    Functional dyspepsia (FD) has been a worldwide complaint. More effective therapies are needed with fewer adverse effects than are seen with conventional medications. Acupuncture, as a traditional therapeutic method, has been widely used for functional gastrointestinal disorders in the East. Manual acupuncture and electroacupuncture have been recognized treatments for FD, but to date, no robust evidence has been found for the effectiveness and safety of these interventions in the treatment of this condition. This review was conducted to assess the efficacy and safety of manual acupuncture and electroacupuncture in the treatment of FD. Trials meeting the inclusion criteria were identified through electronic searches of the Cochrane Central Register of Controlled Trials (CENTRAL), MEDLINE, EMBASE, the Allied and Complementary Medicine Database (AMED), Chinese Biology Medicine Disc (CBMdisc), China National Knowledge Infrastructure (CNKI), the Wanfang Database, the VIP Database, and six trial registries. Handsearching was done to screen the reference sections of potential trials and reviews. Randomized controlled trials (RCTs) were included if investigators reported efficacy and safety of manual acupuncture or electroacupuncture for patients with FD diagnosed by Rome II or Rome III criteria, compared with medications, blank control, or sham acupuncture. Data were extracted by independent review authors. Study limitations were assessed by using the tool of The Cochrane Collabration for assessing risk of bias. For dichotomous data, risk ratios (RRs) and 95% confidence intervals (95% CIs) would be applied, and for continuous data, mean differences (MDs) and 95% CIs. A fixed-effect model was applied in the meta-analysis, or a descriptive analysis was performed. The quality of evidence for the outcome measure was assessed by the Grading of Recommendations Assessment, Development and Evaluation (GRADE) methods. Seven studies were included in the review, involving 542 participants with FD (212 males and 330 females). These studies generally had an unclear risk of bias based on inadequate descriptions of allocation concealment and a high risk of bias based on lack of blinding. None of the studies reported on outcomes of the Functional Digestive Disorder Quality of Life questionnaire (FDDQL), the Satisfaction With Dyspepsia Related Health scale (SODA), the Digestive Health Status Instrument (DHSI), or effective/inefficient rate and symptom recurrence six months from completion of acupuncture treatment.Four RCTs of acupuncture versus medications (cisapride, domperidone, and itopride) were included in the review. No statistically significant difference was noted in the reduction in FD symptom scores and the frequency of FD attack by manual acupuncture, manual-electroacupuncture, or electroacupuncture compared with medications. In three trials of acupuncture versus sham acupuncture, all descriptive or quantitative analysis results implied that acupuncture could improve FD symptom scores and scores on the Neck Disability Index (NDI), the 36-Item Short Form Health Survey (SF-36), the Self-Rating Anxiety Scale (SAS), and the Self-Rating Depression Scale (SDS) more or as significantly as sham acupuncture. With regard to adverse effects, acupuncture was superior to cisapride treatment (one study; all minor events), but no statistically significant difference was reported between acupuncture and sham acupuncture. No adverse effects data were reported in studies examining manual acupuncture versus domperidone, manual-electroacupuncture versus domperidone, or electroacupuncture versus itopride.Nevertheless, all evidence was of low or very low quality. The body of evidence identified cannot yet permit a robust conclusion regarding the efficacy and safety of acupuncture for FD. It remains unknown whether manual acupuncture or electroacupuncture is more effective or safer than other treatments for patients with FD.

  2. Commercial Pesticides Applicator Manual: Public Health.

    ERIC Educational Resources Information Center

    Fitzwater, William D.; Reed, Leonard G., Jr.

    This training manual provides information needed to meet the minimum EPA standards for certification as a commercial applicator of pesticides in the public health pest control category. The text discusses pests such as roaches, bedbugs, bees, mosquitoes, gnats, flies, and rodents with possible control measures provided. (CS)

  3. Forest Pest Control and Timber Treatment Category Manual.

    ERIC Educational Resources Information Center

    Bowman, James S.; Turmel, Jon P.

    This manual provides information needed to meet the standards for pesticide applicator certification. The document is a compilation of pamphlets and circulars which discuss forest management, control of undesirable woody plants, herbicides in forestry, diseases and insect pests, and equipment for pesticide application. (CS)

  4. 46 CFR 112.35-1 - General.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... Manually Controlled Emergency Systems Having a Storage Battery or a Diesel Engine or Gas Turbine Driven Generator as the Sole Emergency Power Source § 112.35-1 General. This subpart contains requirements applicable to emergency power installations having a manually controlled storage battery, diesel engine, or...

  5. 46 CFR 112.35-1 - General.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... Manually Controlled Emergency Systems Having a Storage Battery or a Diesel Engine or Gas Turbine Driven Generator as the Sole Emergency Power Source § 112.35-1 General. This subpart contains requirements applicable to emergency power installations having a manually controlled storage battery, diesel engine, or...

  6. Incorporating Manual and Autonomous Code Generation

    NASA Technical Reports Server (NTRS)

    McComas, David

    1998-01-01

    Code can be generated manually or using code-generated software tools, but how do you interpret the two? This article looks at a design methodology that combines object-oriented design with autonomic code generation for attitude control flight software. Recent improvements in space flight computers are allowing software engineers to spend more time engineering the applications software. The application developed was the attitude control flight software for an astronomical satellite called the Microwave Anisotropy Probe (MAP). The MAP flight system is being designed, developed, and integrated at NASA's Goddard Space Flight Center. The MAP controls engineers are using Integrated Systems Inc.'s MATRIXx for their controls analysis. In addition to providing a graphical analysis for an environment, MATRIXx includes an autonomic code generation facility called AutoCode. This article examines the forces that shaped the final design and describes three highlights of the design process: (1) Defining the manual to autonomic code interface; (2) Applying object-oriented design to the manual flight code; (3) Implementing the object-oriented design in C.

  7. Variable Lifting Index for Manual-Lifting Risk Assessment: A Preliminary Validation Study.

    PubMed

    Battevi, Natale; Pandolfi, Monica; Cortinovis, Ivan

    2016-08-01

    The aim of this study was to evaluate the efficacy of the new Variable Lifting Index (VLI) method, theoretically based on the Revised National Institute for Occupational Safety and Health [NIOSH] Lifting Equation (RNLE), in predicting the risk of acute low-back pain (LBP) in the past 12 months. A new risk variable termed the VLI for assessing variable manual lifting has been developed, but there has been no epidemiological study that evaluates the relationship between the VLI and LBP. A sample of 3,402 study participants from 16 companies in different industrial sectors was analyzed. Of the participants, 2,374 were in the risk exposure group involving manual materials handling (MMH), and 1,028 were in the control group without MMH. The VLI was calculated for each participant in the exposure group using a systematic approach. LBP information was collected by occupational physicians at the study sites. The risk of acute LBP was estimated by calculating the odds ratio (OR) between levels of the risk exposure and the control group using a logistic regression analysis. Both crude and adjusted ORs for body mass index, gender, and age were analyzed. Both crude and adjusted ORs showed a dose-response relationship. As the levels of VLI increased, the risk of LBP increased. This risk relationship existed when VLI was greater than 1. The VLI method can be used to assess the risk of acute LBP, although further studies are needed to confirm the outcome and to define better VLI categories. © 2016, Human Factors and Ergonomics Society.

  8. Camellia v1.0 Manual: Part I

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Roberts, Nathan V.

    2016-09-28

    Camellia began as an effort to simplify implementation of efficient solvers for the discontinuous Petrov-Galerkin (DPG) finite element methodology of Demkowicz and Gopalakrishnan. Since then, the feature set has expanded, to allow implementation of traditional continuous Galerkin methods, as well as discontinuous Galerkin (DG) methods, hybridizable DG (HDG) methods, first-order-system least squares (FOSLS), and the primal DPG method. This manual serves as an introduction to using Camellia. We begin, in Section 1.1, by describing some of the core features of Camellia. In Section 1.2 we provide an outline of the manual as a whole.

  9. Microprocessor controlled compliance monitor for eye drop medication

    PubMed Central

    Hermann, M M; Diestelhorst, M

    2006-01-01

    Background/aims The effectiveness of a self administered eye drop medication can only be assessed if the compliance is known. The authors studied the specificity and sensitivity of a new microprocessor controlled monitoring device. Methods The monitoring system was conducted by an 8 bit microcontroller for data acquisition and storage with sensors measuring applied pressure to the bottle, temperature, and vertical position. 10 devices were mounted under commercial 10 ml eye drops. Test subjects had to note down each application manually. A total of 15 applications each within 3 days was intended. Results Manual reports confirmed 15 applications for each of the 10 bottles. The monitoring devices detected a total of 149 events; one was missed; comprising a sensitivity of 99%. Two devices registered three applications, which did not appear in the manual protocols, indicating a specificity of about 98%. Refrigerated bottles were correctly identified. The battery lifetime exceeded 60 days. Conclusion The new monitoring device demonstrated a high reliability of the collected compliance data. The important, yet often unknown, influence of compliance in patient care and clinical trials shall be illuminated by the new device. This may lead to a better adapted patient care. Studies will profit from a higher credibility and results will be less influenced by non‐compliance. PMID:16540488

  10. Eye-Hand Synergy and Intermittent Behaviors during Target-Directed Tracking with Visual and Non-visual Information

    PubMed Central

    Huang, Chien-Ting; Hwang, Ing-Shiou

    2012-01-01

    Visual feedback and non-visual information play different roles in tracking of an external target. This study explored the respective roles of the visual and non-visual information in eleven healthy volunteers who coupled the manual cursor to a rhythmically moving target of 0.5 Hz under three sensorimotor conditions: eye-alone tracking (EA), eye-hand tracking with visual feedback of manual outputs (EH tracking), and the same tracking without such feedback (EHM tracking). Tracking error, kinematic variables, and movement intermittency (saccade and speed pulse) were contrasted among tracking conditions. The results showed that EHM tracking exhibited larger pursuit gain, less tracking error, and less movement intermittency for the ocular plant than EA tracking. With the vision of manual cursor, EH tracking achieved superior tracking congruency of the ocular and manual effectors with smaller movement intermittency than EHM tracking, except that the rate precision of manual action was similar for both types of tracking. The present study demonstrated that visibility of manual consequences altered mutual relationships between movement intermittency and tracking error. The speed pulse metrics of manual output were linked to ocular tracking error, and saccade events were time-locked to the positional error of manual tracking during EH tracking. In conclusion, peripheral non-visual information is critical to smooth pursuit characteristics and rate control of rhythmic manual tracking. Visual information adds to eye-hand synchrony, underlying improved amplitude control and elaborate error interpretation during oculo-manual tracking. PMID:23236498

  11. Manual for a Volunteer Services System.

    ERIC Educational Resources Information Center

    Helgerson, Linda; And Others

    This manual presents guidelines for planning, monitoring, and controlling the development and operation of volunteer assistance programs. The materials included address questions related to both the process of establishing a volunteer program and the administration of a volunteer management system. The manual is not intended to provide a blueprint…

  12. 46 CFR 112.35-5 - Manually started emergency systems.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ....35-5 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) ELECTRICAL ENGINEERING EMERGENCY LIGHTING AND POWER SYSTEMS Manually Controlled Emergency Systems Having a Storage Battery or a Diesel Engine or Gas Turbine Driven Generator as the Sole Emergency Power Source § 112.35-5 Manually...

  13. 46 CFR 112.35-5 - Manually started emergency systems.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ....35-5 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) ELECTRICAL ENGINEERING EMERGENCY LIGHTING AND POWER SYSTEMS Manually Controlled Emergency Systems Having a Storage Battery or a Diesel Engine or Gas Turbine Driven Generator as the Sole Emergency Power Source § 112.35-5 Manually...

  14. 46 CFR 112.35-5 - Manually started emergency systems.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ....35-5 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) ELECTRICAL ENGINEERING EMERGENCY LIGHTING AND POWER SYSTEMS Manually Controlled Emergency Systems Having a Storage Battery or a Diesel Engine or Gas Turbine Driven Generator as the Sole Emergency Power Source § 112.35-5 Manually...

  15. 46 CFR 112.35-5 - Manually started emergency systems.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ....35-5 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) ELECTRICAL ENGINEERING EMERGENCY LIGHTING AND POWER SYSTEMS Manually Controlled Emergency Systems Having a Storage Battery or a Diesel Engine or Gas Turbine Driven Generator as the Sole Emergency Power Source § 112.35-5 Manually...

  16. 46 CFR 112.35-5 - Manually started emergency systems.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ....35-5 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) ELECTRICAL ENGINEERING EMERGENCY LIGHTING AND POWER SYSTEMS Manually Controlled Emergency Systems Having a Storage Battery or a Diesel Engine or Gas Turbine Driven Generator as the Sole Emergency Power Source § 112.35-5 Manually...

  17. 21 CFR 886.1770 - Manual refractor.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... DEVICES OPHTHALMIC DEVICES Diagnostic Devices § 886.1770 Manual refractor. (a) Identification. A manual refractor is a device that is a set of lenses of varous dioptric powers intended to measure the refractive error of the eye. (b) Classification. Class I (general controls). The device is exempt from the...

  18. Hazardous Waste Minimization Assessment: Fort Meade, MD

    DTIC Science & Technology

    1991-01-01

    Manual TSCA Toxic Substances Control Act TSDF T.xatment. Storage, and Disposal Facility USACERL U.S. Army Construction Engineering Research Laboratory...generation; and current methods of treatment, storage, and disposal, researchers conducted feasibility and economicanalyses of milnimizaion options...Bernard A. Donahue 7. PERFORMING ORGANIZATION NAME(S) ANO ADO ESS(ES) S. PERFORMING ORGANIZATION REPORT NUMBER U.S. Army Construction Engineering Research

  19. PAN AIR: A computer program for predicting subsonic or supersonic linear potential flows about arbitrary configurations using a higher order panel method. Volume 2: User's manual (version 3.0)

    NASA Technical Reports Server (NTRS)

    Sidwell, Kenneth W.; Baruah, Pranab K.; Bussoletti, John E.; Medan, Richard T.; Conner, R. S.; Purdon, David J.

    1990-01-01

    A comprehensive description of user problem definition for the PAN AIR (Panel Aerodynamics) system is given. PAN AIR solves the 3-D linear integral equations of subsonic and supersonic flow. Influence coefficient methods are used which employ source and doublet panels as boundary surfaces. Both analysis and design boundary conditions can be used. This User's Manual describes the information needed to use the PAN AIR system. The structure and organization of PAN AIR are described, including the job control and module execution control languages for execution of the program system. The engineering input data are described, including the mathematical and physical modeling requirements. Version 3.0 strictly applies only to PAN AIR version 3.0. The major revisions include: (1) inputs and guidelines for the new FDP module (which calculates streamlines and offbody points); (2) nine new class 1 and class 2 boundary conditions to cover commonly used modeling practices, in particular the vorticity matching Kutta condition; (3) use of the CRAY solid state Storage Device (SSD); and (4) incorporation of errata and typo's together with additional explanation and guidelines.

  20. An attentive multi-camera system

    NASA Astrophysics Data System (ADS)

    Napoletano, Paolo; Tisato, Francesco

    2014-03-01

    Intelligent multi-camera systems that integrate computer vision algorithms are not error free, and thus both false positive and negative detections need to be revised by a specialized human operator. Traditional multi-camera systems usually include a control center with a wall of monitors displaying videos from each camera of the network. Nevertheless, as the number of cameras increases, switching from a camera to another becomes hard for a human operator. In this work we propose a new method that dynamically selects and displays the content of a video camera from all the available contents in the multi-camera system. The proposed method is based on a computational model of human visual attention that integrates top-down and bottom-up cues. We believe that this is the first work that tries to use a model of human visual attention for the dynamic selection of the camera view of a multi-camera system. The proposed method has been experimented in a given scenario and has demonstrated its effectiveness with respect to the other methods and manually generated ground-truth. The effectiveness has been evaluated in terms of number of correct best-views generated by the method with respect to the camera views manually generated by a human operator.

  1. Analytical methods manual for the Mineral Resource Surveys Program, U.S. Geological Survey

    USGS Publications Warehouse

    Arbogast, Belinda F.

    1996-01-01

    The analytical methods validated by the Mineral Resource Surveys Program, Geologic Division, is the subject of this manual. This edition replaces the methods portion of Open-File Report 90-668 published in 1990. Newer methods may be used which have been approved by the quality assurance (QA) project and are on file with the QA coordinator.This manual is intended primarily for use by laboratory scientists; this manual can also assist laboratory users to evaluate the data they receive. The analytical methods are written in a step by step approach so that they may be used as a training tool and provide detailed documentation of the procedures for quality assurance. A "Catalog of Services" is available for customer (submitter) use with brief listings of:the element(s)/species determined,method of determination,reference to cite,contact person,summary of the technique,and analyte concentration range.For a copy please contact the Branch office at (303) 236-1800 or fax (303) 236-3200.

  2. Mixed methods research - the best of both worlds?

    PubMed

    van Griensven, Hubert; Moore, Ann P; Hall, Valerie

    2014-10-01

    There has been a bias towards quantitative research approaches within manual therapy, which may have resulted in a narrow understanding of manual therapy practice. The aim of this Masterclass is to make a contribution to the expansion of methodologies used in manual therapy enquiry by discussing mixed methods research (MMR), a methodology which utilises both qualitative and quantitative methods within a single study in order to provide more comprehensive insights. To review rationales for MMR, as well as some of the common design options and potential difficulties. The paper also discusses theoretical frameworks that have been used to underpin qualitative and quantitative research, and ongoing debates about the possibility of combining them. Complexities associated with health and manual therapy cannot always be investigated satisfactorily by using a single research method. Some issues require a more comprehensive understanding, which may be provided by combining the strengths of quantitative and qualitative methods in a mixed methods study. Copyright © 2014 Elsevier Ltd. All rights reserved.

  3. Phantom Study Investigating the Accuracy of Manual and Automatic Image Fusion with the GE Logiq E9: Implications for use in Percutaneous Liver Interventions.

    PubMed

    Burgmans, Mark Christiaan; den Harder, J Michiel; Meershoek, Philippa; van den Berg, Nynke S; Chan, Shaun Xavier Ju Min; van Leeuwen, Fijs W B; van Erkel, Arian R

    2017-06-01

    To determine the accuracy of automatic and manual co-registration methods for image fusion of three-dimensional computed tomography (CT) with real-time ultrasonography (US) for image-guided liver interventions. CT images of a skills phantom with liver lesions were acquired and co-registered to US using GE Logiq E9 navigation software. Manual co-registration was compared to automatic and semiautomatic co-registration using an active tracker. Also, manual point registration was compared to plane registration with and without an additional translation point. Finally, comparison was made between manual and automatic selection of reference points. In each experiment, accuracy of the co-registration method was determined by measurement of the residual displacement in phantom lesions by two independent observers. Mean displacements for a superficial and deep liver lesion were comparable after manual and semiautomatic co-registration: 2.4 and 2.0 mm versus 2.0 and 2.5 mm, respectively. Both methods were significantly better than automatic co-registration: 5.9 and 5.2 mm residual displacement (p < 0.001; p < 0.01). The accuracy of manual point registration was higher than that of plane registration, the latter being heavily dependent on accurate matching of axial CT and US images by the operator. Automatic reference point selection resulted in significantly lower registration accuracy compared to manual point selection despite lower root-mean-square deviation (RMSD) values. The accuracy of manual and semiautomatic co-registration is better than that of automatic co-registration. For manual co-registration using a plane, choosing the correct plane orientation is an essential first step in the registration process. Automatic reference point selection based on RMSD values is error-prone.

  4. Logistics and operations implications of manual control of spacecraft docking maneuvers

    NASA Technical Reports Server (NTRS)

    Brody, Adam R.; Ellis, Stephen R.

    1991-01-01

    The implications of logistics and operations on the manual control of spacecraft docking are discussed. The results of simulation studies to investigate fuel and time cost tradeoffs are reviewed and discussed. Comparisons of acceleration control and pulse control are presented to evaluate the effects of astronauts being instructed to use pulse mode for fuel conservation. The applications of the findings to moon and Mars missions are addressed.

  5. Implementation and control of a 3 degree-of-freedom, force-reflecting manual controller

    NASA Astrophysics Data System (ADS)

    Kim, Whee-Kuk; Bevill, Pat; Tesar, Delbert

    1991-02-01

    Most available manual controllers which are used in bilateral or force-reflecting teleoperator systems can be characterized by their bulky size heavy weight high cost low magnitude of reflecting-force lack of smoothness insufficient transparency and simplified architectures. A compact smooth lightweight portable universal manual controller could provide a markedly improved level of transparency and be able to drive a broad spectrum of slave manipulators. This implies that a single stand-off position could be used for a diverse population of remote systems and that a standard environment for training of operators would result in reduced costs and higher reliability. In the implementation presented in this paper a parallel 3 degree-of-freedom (DOF) spherical structure (for compactness and reduced weight) is combined with high gear-ratio reducers using a force control algorithm to produce a " power steering" effect for enhanced smoothness and transparency. The force control algorithm has the further benefit of minimizing the effect of the system friction and non-linear inertia forces. The fundamental analytical description for the spherical force-reflecting manual controller such as forward position analysis reflecting-force transformation and applied force control algorithm are presented. Also a brief description of the system integration its actual implementation and preliminary test results are presented in the paper.

  6. An Improved Manual Method for NOx Emission Measurement.

    ERIC Educational Resources Information Center

    Dee, L. A.; And Others

    The current manual NO (x) sampling and analysis method was evaluated. Improved time-integrated sampling and rapid analysis methods were developed. In the new method, the sample gas is drawn through a heated bed of uniquely active, crystalline, Pb02 where NO (x) is quantitatively absorbed. Nitrate ion is later extracted with water and the…

  7. A scalable, fully automated process for construction of sequence-ready human exome targeted capture libraries

    PubMed Central

    2011-01-01

    Genome targeting methods enable cost-effective capture of specific subsets of the genome for sequencing. We present here an automated, highly scalable method for carrying out the Solution Hybrid Selection capture approach that provides a dramatic increase in scale and throughput of sequence-ready libraries produced. Significant process improvements and a series of in-process quality control checkpoints are also added. These process improvements can also be used in a manual version of the protocol. PMID:21205303

  8. Registration of T2-weighted and diffusion-weighted MR images of the prostate: comparison between manual and landmark-based methods

    NASA Astrophysics Data System (ADS)

    Peng, Yahui; Jiang, Yulei; Soylu, Fatma N.; Tomek, Mark; Sensakovic, William; Oto, Aytekin

    2012-02-01

    Quantitative analysis of multi-parametric magnetic resonance (MR) images of the prostate, including T2-weighted (T2w) and diffusion-weighted (DW) images, requires accurate image registration. We compared two registration methods between T2w and DW images. We collected pre-operative MR images of 124 prostate cancer patients (68 patients scanned with a GE scanner and 56 with Philips scanners). A landmark-based rigid registration was done based on six prostate landmarks in both T2w and DW images identified by a radiologist. Independently, a researcher manually registered the same images. A radiologist visually evaluated the registration results by using a 5-point ordinal scale of 1 (worst) to 5 (best). The Wilcoxon signed-rank test was used to determine whether the radiologist's ratings of the results of the two registration methods were significantly different. Results demonstrated that both methods were accurate: the average ratings were 4.2, 3.3, and 3.8 for GE, Philips, and all images, respectively, for the landmark-based method; and 4.6, 3.7, and 4.2, respectively, for the manual method. The manual registration results were more accurate than the landmark-based registration results (p < 0.0001 for GE, Philips, and all images). Therefore, the manual method produces more accurate registration between T2w and DW images than the landmark-based method.

  9. Evaluation of discrepancies between thermoluminescent dosimeter and direct-reading dosimeter results

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Shaw, K.R.

    1993-07-01

    Currently at Oak Ridge National Laboratory (ORNL), the responses of thermoluminescent dosimeters (TLDs) and direct-reading dosimeters (DRDs) are not officially compared or the discrepancies investigated. However, both may soon be required due to the new US Department of Energy (DOE) Radiological Control Manual. In the past, unofficial comparisons of the two dosimeters have led to discrepancies of up to 200%. This work was conducted to determine the reasons behind such discrepancies. For tests conducted with the TLDs, the reported dose was most often lower than the delivered dose, while DRDs most often responded higher than the delivered dose. Trends weremore » identified in personnel DRD readings, and ft was concluded that more training and more control of the DRDs could improve their response. TLD responses have already begun to be improved; a new background subtraction method was implemented in April 1993, and a new dose algorithm is being considered. It was concluded that the DOE Radiological Control Manual requirements are reasonable for identifying discrepancies between dosimeter types, and more stringent administrative limits might even be considered.« less

  10. A New Semi-Automatic Approach to Find Suitable Virtual Electrodes in Arrays Using an Interpolation Strategy.

    PubMed

    Salchow, Christina; Valtin, Markus; Seel, Thomas; Schauer, Thomas

    2016-06-13

    Functional Electrical Stimulation via electrode arrays enables the user to form virtual electrodes (VEs) of dynamic shape, size, and position. We developed a feedback-control-assisted manual search strategy which allows the therapist to conveniently and continuously modify VEs to find a good stimulation area. This works for applications in which the desired movement consists of at least two degrees of freedom. The virtual electrode can be moved to arbitrary locations within the array, and each involved element is stimulated with an individual intensity. Meanwhile, the applied global stimulation intensity is controlled automatically to meet a predefined angle for one degree of freedom. This enables the therapist to concentrate on the remaining degree(s) of freedom while changing the VE position. This feedback-control-assisted approach aims to integrate the user's opinion and the patient's sensation. Therefore, our method bridges the gap between manual search and fully automatic identification procedures for array electrodes. Measurements in four healthy volunteers were performed to demonstrate the usefulness of our concept, using a 24-element array to generate wrist and hand extension.

  11. MASQOT: a method for cDNA microarray spot quality control

    PubMed Central

    Bylesjö, Max; Eriksson, Daniel; Sjödin, Andreas; Sjöström, Michael; Jansson, Stefan; Antti, Henrik; Trygg, Johan

    2005-01-01

    Background cDNA microarray technology has emerged as a major player in the parallel detection of biomolecules, but still suffers from fundamental technical problems. Identifying and removing unreliable data is crucial to prevent the risk of receiving illusive analysis results. Visual assessment of spot quality is still a common procedure, despite the time-consuming work of manually inspecting spots in the range of hundreds of thousands or more. Results A novel methodology for cDNA microarray spot quality control is outlined. Multivariate discriminant analysis was used to assess spot quality based on existing and novel descriptors. The presented methodology displays high reproducibility and was found superior in identifying unreliable data compared to other evaluated methodologies. Conclusion The proposed methodology for cDNA microarray spot quality control generates non-discrete values of spot quality which can be utilized as weights in subsequent analysis procedures as well as to discard spots of undesired quality using the suggested threshold values. The MASQOT approach provides a consistent assessment of spot quality and can be considered an alternative to the labor-intensive manual quality assessment process. PMID:16223442

  12. Neural manual vs. robotic assisted mobilization to improve motion and reduce pain hypersensitivity in hand osteoarthritis: study protocol for a randomized controlled trial.

    PubMed

    Villafañe, Jorge Hugo; Valdes, Kristin; Imperio, Grace; Borboni, Alberto; Cantero-Téllez, Raquel; Galeri, Silvia; Negrini, Stefano

    2017-05-01

    [Purpose] The aim of the present study is to detail the protocol for a randomised controlled trial (RCT) of neural manual vs. robotic assisted on pain in sensitivity as well as analyse the quantitative and qualitative movement of hand in subjects with hand osteoarthritis. [Subjects and Methods] Seventy-two patients, aged 50 to 90 years old of both genders, with a diagnosis of hand Osteoarthritis (OA), will be recruited. Two groups of 36 participants will receive an experimental intervention (neurodynamic mobilization intervention plus exercise) or a control intervention (robotic assisted passive mobilization plus exercise) for 12 sessions over 4 weeks. Assessment points will be at baseline, end of therapy, and 1 and 3 months after end of therapy. The outcomes of this intervention will be pain and determine the central pain processing mechanisms. [Result] Not applicable. [Conclusion] If there is a reduction in pain hypersensitivity in hand OA patients it can suggest that supraspinal pain-inhibitory areas, including the periaqueductal gray matter, can be stimulated by joint mobilization.

  13. Parenting Manuals on Underage Drinking: Differences between Alcohol Industry and Non-Industry Publications

    ERIC Educational Resources Information Center

    Lindsay, Gordon B.; Merrill, Ray M.; Owens, Adam; Barleen, Nathan A.

    2008-01-01

    Background: There is some debate over the efficacy of alcohol industry parenting manuals. Purpose: This study compares the content and focus of alcohol industry and non-industry "talk to your child about drinking" parenting manuals. Methods: Parenting manuals from Anheuser-Busch and Miller Brewing Company were compared to federal government and…

  14. Cerebella segmentation on MR images of pediatric patients with medulloblastoma

    NASA Astrophysics Data System (ADS)

    Shan, Zu Y.; Ji, Qing; Glass, John; Gajjar, Amar; Reddick, Wilburn E.

    2005-04-01

    In this study, an automated method has been developed to identify the cerebellum from T1-weighted MR brain images of patients with medulloblastoma. A new objective function that is similar to Gibbs free energy in classic physics was defined; and the brain structure delineation was viewed as a process of minimizing Gibbs free energy. We used a rigid-body registration and an active contour (snake) method to minimize the Gibbs free energy in this study. The method was applied to 20 patient data sets to generate cerebellum images and volumetric results. The generated cerebellum images were compared with two manually drawn results. Strong correlations were found between the automatically and manually generated volumetric results, the correlation coefficients with each of manual results were 0.971 and 0.974, respectively. The average Jaccard similarities with each of two manual results were 0.89 and 0.88, respectively. The average Kappa indexes with each of two manual results were 0.94 and 0.93, respectively. These results showed this method was both robust and accurate for cerebellum segmentation. The method may be applied to various research and clinical investigation in which cerebellum segmentation and quantitative MR measurement of cerebellum are needed.

  15. Air Controlman 1 & C: Rate Training Manual.

    ERIC Educational Resources Information Center

    Naval Training Command, Pensacola, FL.

    The manual is designed for use in preparing for advancement within the Navy Air Controlman rating, which designates a professional air traffic controller, unlike the more specialized center or tower controllers. However, minimum qualifications for the rating include completion of the Federal Aviation Administration (FAA) written examination for…

  16. Agricultural Plant Pest Control. Manual 93.

    ERIC Educational Resources Information Center

    Missouri Univ., Columbia. Agricultural Experiment Station.

    This training manual provides information needed to meet the minimum EPA standards for certification as a commercial applicator of pesticides for the agricultural plant pest control category. The text discusses the insect pests including caterpillars, beetles, and soil inhabiting insects; diseases and nematodes; and weeds. Consideration is given…

  17. Commercial Pesticides Applicator Manual: Agriculture - Plant.

    ERIC Educational Resources Information Center

    Fitzwater, W. D.; And Others

    This training manual provides information needed to meet the minimum EPA standards for certification as a commercial applicator of pesticides in the agriculture-plant pest control category. The text discusses identification and control of insects, diseases, nematodes, and weeds of agricultural crops. Proper use of application equipment and safety…

  18. 33 CFR 164.11 - Navigation under way: General.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... maintain an exact position because strong or varying currents, heavy seas, ice, and collisions with vessels... the navigating bridge is operated to determine if the steering equipment is operating properly under manual control, unless the vessel has been steered under manual control from the navigating bridge within...

  19. 33 CFR 164.11 - Navigation under way: General.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... maintain an exact position because strong or varying currents, heavy seas, ice, and collisions with vessels... the navigating bridge is operated to determine if the steering equipment is operating properly under manual control, unless the vessel has been steered under manual control from the navigating bridge within...

  20. Iowa Commercial Pesticide Applicator Manual, Category 7A: General and Household Pest Control. CS-19. Category 7B: Termite Control, CS-20. Category 7C: Food Industry Pest Control, CS-21. Category 7D: Community Insect Control, CS-22.

    ERIC Educational Resources Information Center

    Stockdale, Harold J., Ed.; And Others

    This manual provides information needed to meet specific standards for certification as a pesticide applicator. The first section discusses general and household pest control and is concerned with parasitic pests and man, stored product pests, and irritating vertebrates. Section two is devoted to identifying and controlling structural pests such…

  1. A simulation study of emergency lunar escape to orbit using several simplified manual guidance and control techniques

    NASA Technical Reports Server (NTRS)

    Middleton, D. B.; Hurt, G. J., Jr.

    1971-01-01

    A fixed-base piloted simulator investigation has been made of the feasibility of using any of several manual guidance and control techniques for emergency lunar escape to orbit with very simplified, lightweight vehicle systems. The escape-to-orbit vehicles accommodate two men, but one man performs all of the guidance and control functions. Three basic attitude-control modes and four manually executed trajectory-guidance schemes were used successfully during approximately 125 simulated flights under a variety of conditions. These conditions included thrust misalinement, uneven propellant drain, and a vehicle moment-of-inertia range of 250 to 12,000 slugs per square foot. Two types of results are presented - orbit characteristics and pilot ratings of vehicle handling qualities.

  2. An Improved Genetic Fuzzy Logic Control Method to Reduce the Enlargement of Coal Floor Deformation in Shearer Memory Cutting Process

    PubMed Central

    Tan, Chao; Xu, Rongxin; Wang, Zhongbin; Si, Lei; Liu, Xinhua

    2016-01-01

    In order to reduce the enlargement of coal floor deformation and the manual adjustment frequency of rocker arms, an improved approach through integration of improved genetic algorithm and fuzzy logic control (GFLC) method is proposed. The enlargement of coal floor deformation is analyzed and a model is built. Then, the framework of proposed approach is built. Moreover, the constituents of GA such as tangent function roulette wheel selection (Tan-RWS) selection, uniform crossover, and nonuniform mutation are employed to enhance the performance of GFLC. Finally, two simulation examples and an industrial application example are carried out and the results indicate that the proposed method is feasible and efficient. PMID:27217824

  3. Automatic alignment method for calibration of hydrometers

    NASA Astrophysics Data System (ADS)

    Lee, Y. J.; Chang, K. H.; Chon, J. C.; Oh, C. Y.

    2004-04-01

    This paper presents a new method to automatically align specific scale-marks for the calibration of hydrometers. A hydrometer calibration system adopting the new method consists of a vision system, a stepping motor, and software to control the system. The vision system is composed of a CCD camera and a frame grabber, and is used to acquire images. The stepping motor moves the camera, which is attached to the vessel containing a reference liquid, along the hydrometer. The operating program has two main functions: to process images from the camera to find the position of the horizontal plane and to control the stepping motor for the alignment of the horizontal plane with a particular scale-mark. Any system adopting this automatic alignment method is a convenient and precise means of calibrating a hydrometer. The performance of the proposed method is illustrated by comparing the calibration results using the automatic alignment method with those obtained using the manual method.

  4. Safe, Effective Use of Pesticides, A Manual for Commercial Applicators: Right-of-Way Pest Control.

    ERIC Educational Resources Information Center

    Extension Service (USDA), Washington, DC.

    This manual is intended to assist pesticide applicators who are engaged in right-of-way pest control to meet the requirements of the Michigan Department of Agriculture for certification. While the majority of material in this guide pertains to vegetation management, the guide also addresses right-of-way insect and fungus control. An introduction…

  5. Socioeconomic status and the risk of developing rheumatoid arthritis: results from the Swedish EIRA study

    PubMed Central

    Bengtsson, C; Nordmark, B; Klareskog, L; Lundberg, I; Alfredsson, L; the, E

    2005-01-01

    Objective: To study whether formal education and occupational class are associated with incidence of rheumatoid arthritis overall and with the incidence of the two major subgroups of rheumatoid arthritis—seropositive (RF+) and seronegative (RF–) disease. Methods: 930 cases and 1126 controls participated in a population based case–control study using incident cases of rheumatoid arthritis, carried out in Sweden during the period May 1996 to June 2001. The relative risk (RR) of developing rheumatoid arthritis with 95% confidence interval (CI) was calculated for different levels of formal education compared with university degree and for different occupational classes compared with higher non-manual employees. Results: Subjects without a university degree had an increased risk of rheumatoid arthritis compared with those with a university degree (RR = 1.4 (95% CI, 1.2 to 1.8)). For manual employees, assistant and intermediate non-manual employees together, the risk of developing rheumatoid arthritis was about 20% more than for non-manual employees. These increased risks were more pronounced for RF+ than for RF– rheumatoid arthritis and were mainly confined to women. Smoking could not of its own explain the observed associations between risk of rheumatoid arthritis in different socioeconomic groups in Sweden. Conclusions: There was an association between high socioeconomic status and lower risk of rheumatoid arthritis in a population based investigation that was representative for the Swedish population. The study shows that as yet unexplained environmental or lifestyle factors, or both, influence the risk of rheumatoid arthritis, even in the relatively egalitarian Swedish society. PMID:15843455

  6. Estimation of Time-Varying Pilot Model Parameters

    NASA Technical Reports Server (NTRS)

    Zaal, Peter M. T.; Sweet, Barbara T.

    2011-01-01

    Human control behavior is rarely completely stationary over time due to fatigue or loss of attention. In addition, there are many control tasks for which human operators need to adapt their control strategy to vehicle dynamics that vary in time. In previous studies on the identification of time-varying pilot control behavior wavelets were used to estimate the time-varying frequency response functions. However, the estimation of time-varying pilot model parameters was not considered. Estimating these parameters can be a valuable tool for the quantification of different aspects of human time-varying manual control. This paper presents two methods for the estimation of time-varying pilot model parameters, a two-step method using wavelets and a windowed maximum likelihood estimation method. The methods are evaluated using simulations of a closed-loop control task with time-varying pilot equalization and vehicle dynamics. Simulations are performed with and without remnant. Both methods give accurate results when no pilot remnant is present. The wavelet transform is very sensitive to measurement noise, resulting in inaccurate parameter estimates when considerable pilot remnant is present. Maximum likelihood estimation is less sensitive to pilot remnant, but cannot detect fast changes in pilot control behavior.

  7. Dental Aide. Student Manual [and] Instructor Key. Revised.

    ERIC Educational Resources Information Center

    Heckman, Karen; Noirfalise, Pat

    The first component of this three-part package is a student manual designed to be used independently in secondary health occupations programs or on-the-job training programs for dental assistants. The manual contains seven units that cover the following topics: introduction to dentistry; basic office procedures; infection control and occupational…

  8. 46 CFR 130.480 - Test procedure and operations manual.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 46 Shipping 4 2010-10-01 2010-10-01 false Test procedure and operations manual. 130.480 Section... VESSEL CONTROL, AND MISCELLANEOUS EQUIPMENT AND SYSTEMS Automation of Unattended Machinery Spaces § 130.480 Test procedure and operations manual. (a) A procedure for tests to be conducted on automated...

  9. 40 CFR 63.545 - Standards for fugitive dust sources.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... according to a standard operating procedures manual that describes in detail the measures that will be put... standard operating procedures manual shall be submitted to the Administrator or delegated authority for review and approval. (c) The controls specified in the standard operating procedures manual shall at a...

  10. 40 CFR 63.545 - Standards for fugitive dust sources.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... according to a standard operating procedures manual that describes in detail the measures that will be put... standard operating procedures manual shall be submitted to the Administrator or delegated authority for review and approval. (c) The controls specified in the standard operating procedures manual shall at a...

  11. Exponential error reduction in pretransfusion testing with automation.

    PubMed

    South, Susan F; Casina, Tony S; Li, Lily

    2012-08-01

    Protecting the safety of blood transfusion is the top priority of transfusion service laboratories. Pretransfusion testing is a critical element of the entire transfusion process to enhance vein-to-vein safety. Human error associated with manual pretransfusion testing is a cause of transfusion-related mortality and morbidity and most human errors can be eliminated by automated systems. However, the uptake of automation in transfusion services has been slow and many transfusion service laboratories around the world still use manual blood group and antibody screen (G&S) methods. The goal of this study was to compare error potentials of commonly used manual (e.g., tiles and tubes) versus automated (e.g., ID-GelStation and AutoVue Innova) G&S methods. Routine G&S processes in seven transfusion service laboratories (four with manual and three with automated G&S methods) were analyzed using failure modes and effects analysis to evaluate the corresponding error potentials of each method. Manual methods contained a higher number of process steps ranging from 22 to 39, while automated G&S methods only contained six to eight steps. Corresponding to the number of the process steps that required human interactions, the risk priority number (RPN) of the manual methods ranged from 5304 to 10,976. In contrast, the RPN of the automated methods was between 129 and 436 and also demonstrated a 90% to 98% reduction of the defect opportunities in routine G&S testing. This study provided quantitative evidence on how automation could transform pretransfusion testing processes by dramatically reducing error potentials and thus would improve the safety of blood transfusion. © 2012 American Association of Blood Banks.

  12. A Brief Manualized Treatment for Problematic Caffeine Use: A Randomized Control Trial

    PubMed Central

    Evatt, Daniel P.; Juliano, Laura M.; Griffiths, Roland R.

    2015-01-01

    Objective The goal of the present investigation was to develop and test a brief therapist-guided manualized treatment for problematic caffeine use including cognitive-behavioral strategies and 5-weeks of progressively decreased consumption. Methods Individuals seeking treatment for problematic caffeine use (mean daily caffeine consumption of 666.0 mg at baseline) were randomized using a waitlist-control design to receive immediate (N = 33) treatment or delayed (N = 34) treatment (∼6 weeks later). A one-hour long treatment session designed to help individuals quit or reduce caffeine consumption was provided by a trained counselor along with a take-home booklet. After the treatment session, participants completed daily diaries of caffeine consumption for 5 weeks. They returned for follow-up assessments at 6, 12, and 26 weeks and had a telephone interview at 52-weeks post-treatment. Results Treatment resulted in a significant reduction in self reported caffeine use and salivary caffeine levels. No significant post-treatment increases in caffeine use were observed for up to one year follow-up. Comparisons to the waitlist control condition revealed that reductions in caffeine consumption were due to treatment and not the passing of time, with a treatment effect size of R2 = .35 for the model. Conclusions A brief one-session manualized intervention with follow-up was efficacious at reducing caffeine consumption. Future research should replicate and extend these findings, as well as consider factors affecting dissemination of treatment for problematic caffeine use to those in need. PMID:26501499

  13. TECHNICAL MANUAL: A SURVEY OF EQUIPMENT AND METHODS FOR PARTICULATE SAMPLING IN INDUSTRIAL PROCESS STREAMS

    EPA Science Inventory

    The manual lists and describes the instruments and techniques that are available for measuring the concentration or size distribution of particles suspended in process streams. The standard, official, well established methods are described as well as some experimental methods and...

  14. [Effects of mechanical transplanting of rice with controlled release bulk blending fertilizer on rice yield and soil fertility].

    PubMed

    Zhang, Xuan; Ding, Jun-Shan; Liu, Yan-Ling; Gu, Yan; Han, Ke-Feng; Wu, Liang-Huan

    2014-03-01

    Abstract: A 2-year field experiment with a yellow-clay paddy soil in Zhejiang Province was conducted to study the effects of different planting measures combined with different fertilization practices on rice yield, soil nutrients, microbial biomass C and N and activities of urease, phosphatase, sucrase and hydrogen peroxidase at the maturity stage. Results showed that mechanical transplanting of rice with controlled release bulk blending (BB) fertilizer (BBMT) could achieve a significantly higher mean yield than traditional manual transplanting with traditional fertilizer (TFTM) and direct seeding with controlled release BB fertilizer (BBDS) by 16.3% and 27.0%, respectively. The yield by BBMT was similar to that by traditional manual transplanting with controlled release BB fertilizer (BBTM). Compared with TFTM, BBMT increased the contents of soil total-N, available N, available P and microbial biomass C, and the activities of urease, sucrase and hydrogen peroxidase by 21.5%, 13.6%, 41.2%, 27.1%, 50.0%, 22.5% and 46.2%, respectively. Therefore, BBMT, a simple high-efficiency rice cultivation method with use of a light-weighted mechanical transplanter, should be widely promoted and adopted.

  15. Petrographic methods of examining hardened concrete : a petrographic manual.

    DOT National Transportation Integrated Search

    1997-11-01

    This manual was undertaken to record for all persons wishing to do concrete : petrography the petrographic procedures that have been found useful at the : Virginia Transportation Research Council. The manual is made up of an : introduction and chapte...

  16. Calibration of highway safety manual work zone crash modification factors.

    DOT National Transportation Integrated Search

    2014-06-01

    The Highway Safety Manual is the national safety manual that provides quantitative methods for analyzing highway safety. The : HSM presents crash modification factors related to work zone characteristics such as work zone duration and length. These c...

  17. A decision support tool for identifying abuse of controlled substances by ForwardHealth Medicaid members.

    PubMed

    Mailloux, Allan T; Cummings, Stephen W; Mugdh, Mrinal

    2010-01-01

    Our objective was to use Wisconsin's Medicaid Evaluation and Decision Support (MEDS) data warehouse to develop and validate a decision support tool (DST) that (1) identifies Wisconsin Medicaid fee-for-service recipients who are abusing controlled substances, (2) effectively replicates clinical pharmacist recommendations for interventions intended to curb abuse of physician and pharmacy services, and (3) automates data extraction, profile generation and tracking of recommendations and interventions. From pharmacist manual reviews of medication profiles, seven measures of overutilization of controlled substances were developed, including (1-2) 6-month and 2-month "shopping" scores, (3-4) 6-month and 2-month forgery scores, (5) duplicate/same day prescriptions, (6) count of controlled substance claims, and the (7) shopping 6-month score for the individual therapeutic class with the highest score. The pattern analysis logic for the measures was encoded into SQL and applied to the medication profiles of 190 recipients who had already undergone manual review. The scores for each measure and numbers of providers were analyzed by exhaustive chi-squared automatic interaction detection (CHAID) to determine significant thresholds and combinations of predictors of pharmacist recommendations, resulting in a decision tree to classify recipients by pharmacist recommendations. The overall correct classification rate of the decision tree was 95.3%, with a 2.4% false positive rate and 4.0% false negative rate for lock-in versus prescriber-alert letter recommendations. Measures used by the decision tree include the 2-month and 6-month shopping scores, and the number of pharmacies and prescribers. The number of pharmacies was the best predictor of abuse of controlled substances. When a Medicaid recipient receives prescriptions for controlled substances at 8 or more pharmacies, the likelihood of a lock-in recommendation is 90%. The availability of the Wisconsin MEDS data warehouse has enabled development and application of a decision tree for detecting recipient fraud and abuse of controlled substance medications. Using standard pharmacy claims data, the decision tree effectively replicates pharmacist manual review recommendations. The DST has automated extraction and evaluation of pharmacy claims data for creating recommendations for guiding pharmacists in the selection of profiles for manual review. The DST is now the primary method used by the Wisconsin Medicaid program to detect fraud and abuse of physician and pharmacy services committed by recipients.

  18. Evaluating the quality of a cell counting measurement process via a dilution series experimental design.

    PubMed

    Sarkar, Sumona; Lund, Steven P; Vyzasatya, Ravi; Vanguri, Padmavathy; Elliott, John T; Plant, Anne L; Lin-Gibson, Sheng

    2017-12-01

    Cell counting measurements are critical in the research, development and manufacturing of cell-based products, yet determining cell quantity with accuracy and precision remains a challenge. Validating and evaluating a cell counting measurement process can be difficult because of the lack of appropriate reference material. Here we describe an experimental design and statistical analysis approach to evaluate the quality of a cell counting measurement process in the absence of appropriate reference materials or reference methods. The experimental design is based on a dilution series study with replicate samples and observations as well as measurement process controls. The statistical analysis evaluates the precision and proportionality of the cell counting measurement process and can be used to compare the quality of two or more counting methods. As an illustration of this approach, cell counting measurement processes (automated and manual methods) were compared for a human mesenchymal stromal cell (hMSC) preparation. For the hMSC preparation investigated, results indicated that the automated method performed better than the manual counting methods in terms of precision and proportionality. By conducting well controlled dilution series experimental designs coupled with appropriate statistical analysis, quantitative indicators of repeatability and proportionality can be calculated to provide an assessment of cell counting measurement quality. This approach does not rely on the use of a reference material or comparison to "gold standard" methods known to have limited assurance of accuracy and precision. The approach presented here may help the selection, optimization, and/or validation of a cell counting measurement process. Published by Elsevier Inc.

  19. Fully automatic segmentation of fluorescein leakage in subjects with diabetic macular edema.

    PubMed

    Rabbani, Hossein; Allingham, Michael J; Mettu, Priyatham S; Cousins, Scott W; Farsiu, Sina

    2015-01-29

    To create and validate software to automatically segment leakage area in real-world clinical fluorescein angiography (FA) images of subjects with diabetic macular edema (DME). Fluorescein angiography images obtained from 24 eyes of 24 subjects with DME were retrospectively analyzed. Both video and still-frame images were obtained using a Heidelberg Spectralis 6-mode HRA/OCT unit. We aligned early and late FA frames in the video by a two-step nonrigid registration method. To remove background artifacts, we subtracted early and late FA frames. Finally, after postprocessing steps, including detection and inpainting of the vessels, a robust active contour method was utilized to obtain leakage area in a 1500-μm-radius circular region centered at the fovea. Images were captured at different fields of view (FOVs) and were often contaminated with outliers, as is the case in real-world clinical imaging. Our algorithm was applied to these images with no manual input. Separately, all images were manually segmented by two retina specialists. The sensitivity, specificity, and accuracy of manual interobserver, manual intraobserver, and automatic methods were calculated. The mean accuracy was 0.86 ± 0.08 for automatic versus manual, 0.83 ± 0.16 for manual interobserver, and 0.90 ± 0.08 for manual intraobserver segmentation methods. Our fully automated algorithm can reproducibly and accurately quantify the area of leakage of clinical-grade FA video and is congruent with expert manual segmentation. The performance was reliable for different DME subtypes. This approach has the potential to reduce time and labor costs and may yield objective and reproducible quantitative measurements of DME imaging biomarkers. Copyright 2015 The Association for Research in Vision and Ophthalmology, Inc.

  20. Advantages of combined touch screen technology and text hyperlink for the pathology grossing manual: a simple approach to access instructive information in biohazardous environments.

    PubMed

    Qu, Zhenhong; Ghorbani, Rhonda P; Li, Hongyan; Hunter, Robert L; Hannah, Christina D

    2007-03-01

    Gross examination, encompassing description, dissection, and sampling, is a complex task and an essential component of surgical pathology. Because of the complexity of the task, standardized protocols to guide the gross examination often become a bulky manual that is difficult to use. This problem is further compounded by the high specimen volume and biohazardous nature of the task. As a result, such a manual is often underused, leading to errors that are potentially harmful and time consuming to correct-a common chronic problem affecting many pathology laboratories. To combat this problem, we have developed a simple method that incorporates complex text and graphic information of a typical procedure manual and yet allows easy access to any intended instructive information in the manual. The method uses the Object-Linking-and-Embedding function of Microsoft Word (Microsoft, Redmond, WA) to establish hyperlinks among different contents, and then it uses the touch screen technology to facilitate navigation through the manual on a computer screen installed at the cutting bench with no need for a physical keyboard or a mouse. It takes less than 4 seconds to reach any intended information in the manual by 3 to 4 touches on the screen. A 3-year follow-up study shows that this method has increased use of the manual and has improved the quality of gross examination. The method is simple and can be easily tailored to different formats of instructive information, allowing flexible organization, easy access, and quick navigation. Increased compliance to instructive information reduces errors at the grossing bench and improves work efficiency.

  1. Application of surface geophysics to ground-water investigations

    USGS Publications Warehouse

    Zohdy, Adel A.R.; Eaton, Gordon P.; Mabey, Don R.

    1974-01-01

    This manual reviews the standard methods of surface geophysics applicable to ground-water investigations. It covers electrical methods, seismic and gravity methods, and magnetic methods. The general physical principles underlying each method and its capabilities and limitations are described. Possibilities for non-uniqueness of interpretation of geophysical results are noted. Examples of actual use of the methods are given to illustrate applications and interpretation in selected geohydrologic environments. The objective of the manual is to provide the hydrogeologist with a sufficient understanding of the capabilities, imitations, and relative cost of geophysical methods to make sound decisions as to when to use of these methods is desirable. The manual also provides enough information for the hydrogeologist to work with a geophysicist in designing geophysical surveys that differentiate significant hydrogeologic changes.

  2. Trial Protocol: Cognitive functional therapy compared with combined manual therapy and motor control exercise for people with non-specific chronic low back pain: protocol for a randomised, controlled trial.

    PubMed

    Belache, Fabiana Terra Cunha; Souza, Cíntia Pereira de; Fernandez, Jessica; Castro, Julia; Ferreira, Paula Dos Santos; Rosa, Elizana Rodrigues de Sousa; Araújo, Nathalia Cristina Gimenez de; Reis, Felipe José Jandre; Almeida, Renato Santos de; Nogueira, Leandro Alberto Calazans; Correia, Luís Cláudio Lemos; Meziat-Filho, Ney

    2018-06-11

    Chronic low back pain is a public health problem, and there is strong evidence that it is associated with a complex interaction of biopsychosocial factors. Cognitive functional therapy is an intervention that deals with potentially modifiable multidimensional aspects of pain (eg, provocative cognitive, movement and lifestyle behaviours). There is evidence (from a single randomised, controlled trial) that cognitive functional therapy is better than combined manual therapy and motor control exercise. However, this study had significant methodological shortcomings including the failure to carry out an intention-to-treat analysis and a considerable loss of follow-up of participants. It is important to replicate this study in another domain through a randomised clinical trial with similar objectives but correcting these methodological shortcomings. To investigate the efficacy of cognitive functional therapy compared to combined manual therapy and exercise on pain and disability at 3 months in patients with chronic non-specific low back pain. Two-group, randomised, multicentre controlled trial with blinded assessors. One hundred and forty-eight participants with chronic low back pain that has persisted for >3months and no specific spinal pathology will be recruited from the school clinic of the Centro Universitário Augusto Motta and a private clinic in the city of Rio de Janeiro, Brazil. Four to 10 sessions of cognitive functional therapy. The physiotherapists who will treat the participants in the cognitive functional therapy group have previously attended 2 workshops with two different tutors of the method. Such physiotherapists have completed 106 hours of training, including workshops and patient examinations, as well as conducting a pilot study under the supervision of another physiotherapist with>3 years of clinical experience in cognitive functional therapy. Four to 10 sessions of combined manual therapy and motor control exercises. Participants in the combined manual therapy and exercise group will be treated by two physiotherapists with an average of >10years of clinical experience in manual therapy and motor control exercises, including isolated contractions of the deep abdominal muscles. The primary outcome measures will be pain intensity and disability 3 months after randomisation. Secondary outcomes will be pain and disability assessed 6 and 12 months after randomisation, and both global perceived effect and patient satisfaction at 3, 6 and 12 months after randomisation. The potential outcome mediators will be assessed at 3 and 6 months after randomisation, with brief screening questions for anxiety, social isolation, catastrophisation, depression, fear of movement, stress and sleep. Non-specific predictors and moderators will include age, gender, duration of chronic low back pain, chronicity risk (Örebro and Start Back score), number of pain areas, stressful life event, MRI scan imaging, and family history. Intention-to-treat analysis will be performed. Linear mixed models will be used to compare the mean differences in pain intensity, disability and global perceived effect between the intervention arms. The analysis of the effect of potential mediators of the treatment will be performed using the causal mediation methods described by Imai and colleagues. The baseline variables will be evaluated as predictors and moderators of treatment, including terms and interaction models. A level of statistical significance of 5% will be used in the analysis. All the analyses will be performed using RStudio. This study will investigate whether the results of the first cognitive functional therapy randomised clinical trial are reproducible. The present study will have a sample size capable of detecting clinically relevant effects of the treatment with a low risk of bias. In pragmatic terms, this clinical trial is designed to reproduce the intervention as it would be performed in clinical practice by a trained physiotherapist who works with cognitive functional therapy, which increases the relevance of this study. The combined manual therapy and exercise group comprises an intervention strategy widely used by physiotherapists to treat low back pain. As evidence of efficacy is still limited, the results of a randomised, controlled clinical trial of high methodological quality will help physiotherapists in clinical decision-making. Copyright © 2018 Australian Physiotherapy Association. Published by Elsevier B.V. All rights reserved.

  3. Preharvest manual herbicide treatments for controlling American beech in Central West Virginia

    Treesearch

    Jeffery D. Kochenderfer; James N. Kochenderfer; David A. Warner; Gary W. Miller

    2004-01-01

    Application costs and efficacy were determined for manual preharvest herbicide treatments applied to control American beech (Fagus grandifolia Ehrh.) that was interfering with the establishment and development of black cherry (Prunus serotina Ehrh.) in central West Virginia. The treatments consisted of four levels of basal area...

  4. MFCVs (Manual Flow Control Valves) in the Lab

    NASA Image and Video Library

    2009-07-07

    ISS020-E-017705 (7 July 2009) --- NASA astronaut Michael Barratt, Expedition 20 flight engineer, works at a rotated rack in the Destiny laboratory of the International Space Station during in-flight maintenance (IFM) to adjust the periodic flow rate of manual flow control valves for coolant loops.

  5. MFCVs (Manual Flow Control Valves) in the Lab

    NASA Image and Video Library

    2009-07-07

    ISS020-E-017710 (7 July 2009) --- NASA astronaut Michael Barratt, Expedition 20 flight engineer, works at a rotated rack in the Destiny laboratory of the International Space Station during in-flight maintenance (IFM) to adjust the periodic flow rate of manual flow control valves for coolant loops.

  6. General Pest Control - Industrial. Manual 95.

    ERIC Educational Resources Information Center

    Missouri Univ., Columbia. Agricultural Experiment Station.

    This training manual provides information needed to meet the minimum EPA standards for certification as a commercial applicator of pesticides in the general pest control category. The text discusses general, parasitic and miscellaneous pests such as ants, ticks, and spiders; fabric, wood-destroying, and grain pests such as beetles, termites, and…

  7. PREVENTION REFERENCE MANUAL: OVERVIEWS ON PREVENTING AND CONTROLLING ACCIDENTIAL RELEASES OF SELECTED TOXIC CHEMICALS

    EPA Science Inventory

    The manual can be used to orient personnel involved in inspecting and otherwise evaluating potential toxic chemical release hazards to the fundamentals of release hazard control for 13 of the specific chemicals chosen for evaluation under Section 305(b) of the Superfund Amendment...

  8. Facultative Lagoons. Student Manual. Biological Treatment Process Control.

    ERIC Educational Resources Information Center

    Andersen, Lorri

    The textual material for a unit on facultative lagoons is presented in this student manual. Topic areas discussed include: (1) loading; (2) microbial theory; (3) structure and design; (4) process control; (5) lagoon start-up; (6) data handling and analysis; (7) lagoon maintenance (considering visual observations, pond structure, safety, odor,…

  9. Applying the highway safety manual to Georgia.

    DOT National Transportation Integrated Search

    2015-08-01

    This report examines the Highway Safety Manual (HSM) from the perspective of applying its : methods and approaches within the state of Georgia. The work presented here focuses : specifically on data requirements and methods that may be of particular ...

  10. Computer-Aided Diagnosis of Acute Lymphoblastic Leukaemia

    PubMed Central

    2018-01-01

    Leukaemia is a form of blood cancer which affects the white blood cells and damages the bone marrow. Usually complete blood count (CBC) and bone marrow aspiration are used to diagnose the acute lymphoblastic leukaemia. It can be a fatal disease if not diagnosed at the earlier stage. In practice, manual microscopic evaluation of stained sample slide is used for diagnosis of leukaemia. But manual diagnostic methods are time-consuming, less accurate, and prone to errors due to various human factors like stress, fatigue, and so forth. Therefore, different automated systems have been proposed to wrestle the glitches in the manual diagnostic methods. In recent past, some computer-aided leukaemia diagnosis methods are presented. These automated systems are fast, reliable, and accurate as compared to manual diagnosis methods. This paper presents review of computer-aided diagnosis systems regarding their methodologies that include enhancement, segmentation, feature extraction, classification, and accuracy. PMID:29681996

  11. Comparison of Manual and Automated Measurements of Tracheobronchial Airway Geometry in Three Balb/c Mice.

    PubMed

    Islam, Asef; Oldham, Michael J; Wexler, Anthony S

    2017-11-01

    Mammalian lungs are comprised of large numbers of tracheobronchial airways that transition from the trachea to alveoli. Studies as wide ranging as pollutant deposition and lung development rely on accurate characterization of these airways. Advancements in CT imaging and the value of computational approaches in eliminating the burden of manual measurement are providing increased efficiency in obtaining this geometric data. In this study, we compare an automated method to a manual one for the first six generations of three Balb/c mouse lungs. We find good agreement between manual and automated methods and that much of the disagreement can be attributed to method precision. Using the automated method, we then provide anatomical data for the entire tracheobronchial airway tree from three Balb/C mice. Anat Rec, 2017. © 2017 Wiley Periodicals, Inc. Anat Rec, 300:2046-2057, 2017. © 2017 Wiley Periodicals, Inc. © 2017 Wiley Periodicals, Inc.

  12. Methods for the Determination of Chemical Contaminants in Drinking Water. Training Manual.

    ERIC Educational Resources Information Center

    Office of Water Program Operations (EPA), Cincinnati, OH. National Training and Operational Technology Center.

    This training manual, intended for chemists and technicians with little or no experience in chemical procedures required to monitor drinking water, covers analytical methods for inorganic and organic chemical contaminants listed in the interim primary drinking water regulations. Topics include methods for heavy metals, nitrate, and organic…

  13. Illustrated surface mining methods

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Not Available

    1979-01-01

    This manual provides a visual synopsis of surface coal mining methods in the United States. The manual presents various surface mining methods and techniques through artist renderings and appropriate descriptions. The productive coal fields of the United States were divided into four regions according to geology and physiography. A glossay of terminology is included. (DP)

  14. Analytical Methods for Trace Metals. Training Manual.

    ERIC Educational Resources Information Center

    Office of Water Program Operations (EPA), Cincinnati, OH. National Training and Operational Technology Center.

    This training manual presents material on the theoretical concepts involved in the methods listed in the Federal Register as approved for determination of trace metals. Emphasis is on laboratory operations. This course is intended for chemists and technicians with little or no experience in analytical methods for trace metals. Students should have…

  15. Analysis of FY79 Army Aircraft Accidents.

    DTIC Science & Technology

    1980-04-01

    maintenance and field manuals . *.7 "reel world" Army operations. It Includes detailed lemons Additional requirmnent indifId by the results of the le-a...and 2. Emphb and direction to upgrade training at unit trufe of akrraft control, and school levels. R% eview the current aulons nd manuals to 3. Unit...Evaluation and revision of Army regulations, e Evluate effectiveness of programs desgned to technical manuals , field manuals , and other written Insure

  16. Theoretical linear approach to the combined man-manipulator system in manual control of an aircraft

    NASA Technical Reports Server (NTRS)

    Brauser, K.

    1981-01-01

    An approach to the calculation of the dynamic characteristics of the combined man manipulator system in manual aircraft control was derived from a model of the neuromuscular system. This model combines the neuromuscular properties of man with the physical properties of the manipulator system which is introduced as pilot manipulator model into the manual aircraft control. The assumption of man as a quasilinear and time invariant control operator adapted to operating states, depending on the flight phases, of the control system gives rise to interesting solutions of the frequency domain transfer functions of both the man manipulator system and the closed loop pilot aircraft control system. It is shown that it is necessary to introduce the complete precision pilot manipulator model into the closed loop pilot aircraft transfer function in order to understand the well known handling quality criteria, and to derive these criteria directly from human operator properties.

  17. Modern digital flight control system design for VTOL aircraft

    NASA Technical Reports Server (NTRS)

    Broussard, J. R.; Berry, P. W.; Stengel, R. F.

    1979-01-01

    Methods for and results from the design and evaluation of a digital flight control system (DFCS) for a CH-47B helicopter are presented. The DFCS employed proportional-integral control logic to provide rapid, precise response to automatic or manual guidance commands while following conventional or spiral-descent approach paths. It contained altitude- and velocity-command modes, and it adapted to varying flight conditions through gain scheduling. Extensive use was made of linear systems analysis techniques. The DFCS was designed, using linear-optimal estimation and control theory, and the effects of gain scheduling are assessed by examination of closed-loop eigenvalues and time responses.

  18. Multi-spectral brain tissue segmentation using automatically trained k-Nearest-Neighbor classification.

    PubMed

    Vrooman, Henri A; Cocosco, Chris A; van der Lijn, Fedde; Stokking, Rik; Ikram, M Arfan; Vernooij, Meike W; Breteler, Monique M B; Niessen, Wiro J

    2007-08-01

    Conventional k-Nearest-Neighbor (kNN) classification, which has been successfully applied to classify brain tissue in MR data, requires training on manually labeled subjects. This manual labeling is a laborious and time-consuming procedure. In this work, a new fully automated brain tissue classification procedure is presented, in which kNN training is automated. This is achieved by non-rigidly registering the MR data with a tissue probability atlas to automatically select training samples, followed by a post-processing step to keep the most reliable samples. The accuracy of the new method was compared to rigid registration-based training and to conventional kNN-based segmentation using training on manually labeled subjects for segmenting gray matter (GM), white matter (WM) and cerebrospinal fluid (CSF) in 12 data sets. Furthermore, for all classification methods, the performance was assessed when varying the free parameters. Finally, the robustness of the fully automated procedure was evaluated on 59 subjects. The automated training method using non-rigid registration with a tissue probability atlas was significantly more accurate than rigid registration. For both automated training using non-rigid registration and for the manually trained kNN classifier, the difference with the manual labeling by observers was not significantly larger than inter-observer variability for all tissue types. From the robustness study, it was clear that, given an appropriate brain atlas and optimal parameters, our new fully automated, non-rigid registration-based method gives accurate and robust segmentation results. A similarity index was used for comparison with manually trained kNN. The similarity indices were 0.93, 0.92 and 0.92, for CSF, GM and WM, respectively. It can be concluded that our fully automated method using non-rigid registration may replace manual segmentation, and thus that automated brain tissue segmentation without laborious manual training is feasible.

  19. Dialects for the Stage: A Manual and Two Casette Tapes.

    ERIC Educational Resources Information Center

    Machlin, Evangeline

    This document contains a manual and two cassette tapes designed to help actors and actresses learn to speak various dialects. The tapes and the manual are arranged for the play-it-and-say-it method of dialect acquisition. The first three parts discuss the tapes and the manual in general, the dialect texts and dialect data, and the steps involved…

  20. The comparison of manual and LabVIEW-based fuzzy control on mechanical ventilation.

    PubMed

    Guler, Hasan; Ata, Fikret

    2014-09-01

    The aim of this article is to develop a knowledge-based therapy for management of rats with respiratory distress. A mechanical ventilator was designed to achieve this aim. The designed ventilator is called an intelligent mechanical ventilator since fuzzy logic was used to control the pneumatic equipment according to the rat's status. LabVIEW software was used to control all equipments in the ventilator prototype and to monitor respiratory variables in the experiment. The designed ventilator can be controlled both manually and by fuzzy logic. Eight female Wistar-Albino rats were used to test the designed ventilator and to show the effectiveness of fuzzy control over manual control on pressure control ventilation mode. The anesthetized rats were first ventilated for 20 min manually. After that time, they were ventilated for 20 min by fuzzy logic. Student's t-test for p < 0.05 was applied to the measured minimum, maximum and mean peak inspiration pressures to analyze the obtained results. The results show that there is no statistical difference in the rat's lung parameters before and after the experiments. It can be said that the designed ventilator and developed knowledge-based therapy support artificial respiration of living things successfully. © IMechE 2014.

  1. Improvement of registration accuracy in accelerated partial breast irradiation using the point-based rigid-body registration algorithm for patients with implanted fiducial markers

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Inoue, Minoru; Yoshimura, Michio, E-mail: myossy@kuhp.kyoto-u.ac.jp; Sato, Sayaka

    2015-04-15

    Purpose: To investigate image-registration errors when using fiducial markers with a manual method and the point-based rigid-body registration (PRBR) algorithm in accelerated partial breast irradiation (APBI) patients, with accompanying fiducial deviations. Methods: Twenty-two consecutive patients were enrolled in a prospective trial examining 10-fraction APBI. Titanium clips were implanted intraoperatively around the seroma in all patients. For image-registration, the positions of the clips in daily kV x-ray images were matched to those in the planning digitally reconstructed radiographs. Fiducial and gravity registration errors (FREs and GREs, respectively), representing resulting misalignments of the edge and center of the target, respectively, were comparedmore » between the manual and algorithm-based methods. Results: In total, 218 fractions were evaluated. Although the mean FRE/GRE values for the manual and algorithm-based methods were within 3 mm (2.3/1.7 and 1.3/0.4 mm, respectively), the percentages of fractions where FRE/GRE exceeded 3 mm using the manual and algorithm-based methods were 18.8%/7.3% and 0%/0%, respectively. Manual registration resulted in 18.6% of patients with fractions of FRE/GRE exceeding 5 mm. The patients with larger clip deviation had significantly more fractions showing large FRE/GRE using manual registration. Conclusions: For image-registration using fiducial markers in APBI, the manual registration results in more fractions with considerable registration error due to loss of fiducial objectivity resulting from their deviation. The authors recommend the PRBR algorithm as a safe and effective strategy for accurate, image-guided registration and PTV margin reduction.« less

  2. Effects of Retinal Eccentricity on Human Manual Control

    NASA Technical Reports Server (NTRS)

    Popovici, Alexandru; Zaal, Peter M. T.

    2017-01-01

    This study investigated the effects of viewing a primary flight display at different retinal eccentricities on human manual control behavior and performance. Ten participants performed a pitch tracking task while looking at a simplified primary flight display at different horizontal and vertical retinal eccentricities, and with two different controlled dynamics. Tracking performance declined at higher eccentricity angles and participants behaved more nonlinearly. The visual error rate gain increased with eccentricity for single-integrator-like controlled dynamics, but decreased for double-integrator-like dynamics. Participants' visual time delay was up to 100 ms higher at the highest horizontal eccentricity compared to foveal viewing. Overall, vertical eccentricity had a larger impact than horizontal eccentricity on most of the human manual control parameters and performance. Results might be useful in the design of displays and procedures for critical flight conditions such as in an aerodynamic stall.

  3. High-throughput DNA extraction of forensic adhesive tapes.

    PubMed

    Forsberg, Christina; Jansson, Linda; Ansell, Ricky; Hedman, Johannes

    2016-09-01

    Tape-lifting has since its introduction in the early 2000's become a well-established sampling method in forensic DNA analysis. Sampling is quick and straightforward while the following DNA extraction is more challenging due to the "stickiness", rigidity and size of the tape. We have developed, validated and implemented a simple and efficient direct lysis DNA extraction protocol for adhesive tapes that requires limited manual labour. The method uses Chelex beads and is applied with SceneSafe FAST tape. This direct lysis protocol provided higher mean DNA yields than PrepFiler Express BTA on Automate Express, although the differences were not significant when using clothes worn in a controlled fashion as reference material (p=0.13 and p=0.34 for T-shirts and button-down shirts, respectively). Through in-house validation we show that the method is fit-for-purpose for application in casework, as it provides high DNA yields and amplifiability, as well as good reproducibility and DNA extract stability. After implementation in casework, the proportion of extracts with DNA concentrations above 0.01ng/μL increased from 71% to 76%. Apart from providing higher DNA yields compared with the previous method, the introduction of the developed direct lysis protocol also reduced the amount of manual labour by half and doubled the potential throughput for tapes at the laboratory. Generally, simplified manual protocols can serve as a cost-effective alternative to sophisticated automation solutions when the aim is to enable high-throughput DNA extraction of complex crime scene samples. Copyright © 2016 The Authors. Published by Elsevier Ireland Ltd.. All rights reserved.

  4. Measurement of edge residual stresses in glass by the phase-shifting method

    NASA Astrophysics Data System (ADS)

    Ajovalasit, A.; Petrucci, G.; Scafidi, M.

    2011-05-01

    Control and measurement of residual stress in glass is of great importance in the industrial field. Since glass is a birefringent material, the residual stress analysis is based mainly on the photoelastic method. This paper considers two methods of automated analysis of membrane residual stress in glass sheets, based on the phase-shifting concept in monochromatic light. In particular these methods are the automated versions of goniometric compensation methods of Tardy and Sénarmont. The proposed methods can effectively replace manual methods of compensation (goniometric compensation of Tardy and Sénarmont, Babinet and Babinet-Soleil compensators) provided by current standards on the analysis of residual stresses in glasses.

  5. Carotid stenosis assessment with multi-detector CT angiography: comparison between manual and automatic segmentation methods.

    PubMed

    Zhu, Chengcheng; Patterson, Andrew J; Thomas, Owen M; Sadat, Umar; Graves, Martin J; Gillard, Jonathan H

    2013-04-01

    Luminal stenosis is used for selecting the optimal management strategy for patients with carotid artery disease. The aim of this study is to evaluate the reproducibility of carotid stenosis quantification using manual and automated segmentation methods using submillimeter through-plane resolution Multi-Detector CT angiography (MDCTA). 35 patients having carotid artery disease with >30 % luminal stenosis as identified by carotid duplex imaging underwent contrast enhanced MDCTA. Two experienced CT readers quantified carotid stenosis from axial source images, reconstructed maximum intensity projection (MIP) and 3D-carotid geometry which was automatically segmented by an open-source toolkit (Vascular Modelling Toolkit, VMTK) using NASCET criteria. Good agreement among the measurement using axial images, MIP and automatic segmentation was observed. Automatic segmentation methods show better inter-observer agreement between the readers (intra-class correlation coefficient (ICC): 0.99 for diameter stenosis measurement) than manual measurement of axial (ICC = 0.82) and MIP (ICC = 0.86) images. Carotid stenosis quantification using an automatic segmentation method has higher reproducibility compared with manual methods.

  6. Flight experience with manually controlled unconventional aircraft motions

    NASA Technical Reports Server (NTRS)

    Barfield, A. F.

    1978-01-01

    A modified YF-16 aircraft was used to flight demonstrate decoupled modes under the USAF Fighter Control Configured Vehicle (CCV) Program. The direct force capabilities were used to implement seven manually controlled unconventional modes on the aircraft, allowing flat turns, decoupled normal acceleration control, independent longitudinal and lateral translations, uncoupled elevation and azimuth aiming, and blended direct lift. This paper describes the design, development, and flight testing of these control modes. The need for task-tailored mode authorities, gain-scheduling and selected closed-loop design is discussed.

  7. Supply Management Analysis of the Chilean Navy Acquisition System

    DTIC Science & Technology

    2014-12-01

    52 LIST OF REFERENCES Armada de Chile, N. (1986). Manual de Logistica de la Armada de Chile [Manual of logistics of the Chilean Navy]. Chile... transportation • Quality control • Demand and supply planning • Receiving, materials handling, and storage 11 • Material or inventory control...Order purchasing • Production planning, scheduling, and control • Warehousing and distribution • Shipping • Outbound transportation • Customer

  8. Visuo‐manual tracking: does intermittent control with aperiodic sampling explain linear power and non‐linear remnant without sensorimotor noise?

    PubMed Central

    Gawthrop, Peter J.; Lakie, Martin; Loram, Ian D.

    2017-01-01

    Key points A human controlling an external system is described most easily and conventionally as linearly and continuously translating sensory input to motor output, with the inevitable output remnant, non‐linearly related to the input, attributed to sensorimotor noise.Recent experiments show sustained manual tracking involves repeated refractoriness (insensitivity to sensory information for a certain duration), with the temporary 200–500 ms periods of irresponsiveness to sensory input making the control process intrinsically non‐linear.This evidence calls for re‐examination of the extent to which random sensorimotor noise is required to explain the non‐linear remnant.This investigation of manual tracking shows how the full motor output (linear component and remnant) can be explained mechanistically by aperiodic sampling triggered by prediction error thresholds.Whereas broadband physiological noise is general to all processes, aperiodic sampling is associated with sensorimotor decision making within specific frontal, striatal and parietal networks; we conclude that manual tracking utilises such slow serial decision making pathways up to several times per second. Abstract The human operator is described adequately by linear translation of sensory input to motor output. Motor output also always includes a non‐linear remnant resulting from random sensorimotor noise from multiple sources, and non‐linear input transformations, for example thresholds or refractory periods. Recent evidence showed that manual tracking incurs substantial, serial, refractoriness (insensitivity to sensory information of 350 and 550 ms for 1st and 2nd order systems respectively). Our two questions are: (i) What are the comparative merits of explaining the non‐linear remnant using noise or non‐linear transformations? (ii) Can non‐linear transformations represent serial motor decision making within the sensorimotor feedback loop intrinsic to tracking? Twelve participants (instructed to act in three prescribed ways) manually controlled two systems (1st and 2nd order) subject to a periodic multi‐sine disturbance. Joystick power was analysed using three models, continuous‐linear‐control (CC), continuous‐linear‐control with calculated noise spectrum (CCN), and intermittent control with aperiodic sampling triggered by prediction error thresholds (IC). Unlike the linear mechanism, the intermittent control mechanism explained the majority of total power (linear and remnant) (77–87% vs. 8–48%, IC vs. CC). Between conditions, IC used thresholds and distributions of open loop intervals consistent with, respectively, instructions and previous measured, model independent values; whereas CCN required changes in noise spectrum deviating from broadband, signal dependent noise. We conclude that manual tracking uses open loop predictive control with aperiodic sampling. Because aperiodic sampling is inherent to serial decision making within previously identified, specific frontal, striatal and parietal networks we suggest that these structures are intimately involved in visuo‐manual tracking. PMID:28833126

  9. Variational Trajectory Optimization Tool Set: Technical description and user's manual

    NASA Technical Reports Server (NTRS)

    Bless, Robert R.; Queen, Eric M.; Cavanaugh, Michael D.; Wetzel, Todd A.; Moerder, Daniel D.

    1993-01-01

    The algorithms that comprise the Variational Trajectory Optimization Tool Set (VTOTS) package are briefly described. The VTOTS is a software package for solving nonlinear constrained optimal control problems from a wide range of engineering and scientific disciplines. The VTOTS package was specifically designed to minimize the amount of user programming; in fact, for problems that may be expressed in terms of analytical functions, the user needs only to define the problem in terms of symbolic variables. This version of the VTOTS does not support tabular data; thus, problems must be expressed in terms of analytical functions. The VTOTS package consists of two methods for solving nonlinear optimal control problems: a time-domain finite-element algorithm and a multiple shooting algorithm. These two algorithms, under the VTOTS package, may be run independently or jointly. The finite-element algorithm generates approximate solutions, whereas the shooting algorithm provides a more accurate solution to the optimization problem. A user's manual, some examples with results, and a brief description of the individual subroutines are included.

  10. A randomized controlled trial of manual therapy and pneumatic compression for recovery from prolonged running - an extended study.

    PubMed

    Heapy, Amanda M; Hoffman, Martin D; Verhagen, Heidie H; Thompson, Samuel W; Dhamija, Pavitra; Sandford, Fiona J; Cooper, Mary C

    2018-03-07

    Manual therapy (MT) and intermittent pneumatic compression (IPC) are recovery methods used by endurance athletes with little evidence supporting effectiveness. This randomized controlled trial evaluated effectiveness of four daily post-race treatments of a specific MT protocol and IPC compared with supine rest on recovery following an ultramarathon among 56 ultramarathoners. Groups were comparable across all characteristics examined, including post-race plasma creatine kinase concentration. Subject completed timed 400 m runs before the race and on days three, five, seven and 14 post- race, and also provided muscle pain and soreness ratings and fatigue scores immediately before and after treatments, and during the 14 days post- race. Daily subjective measures and 400 m run times were not improved by either treatment, but both treatments reduced (p < .05) muscular fatigue scores acutely after treatment following the race and on post-race day 1, and MT improved (p < .05) muscle pain and soreness acutely following the race.

  11. ANSI/ASHRAE/IES Standard 90.1-2010 Performance Rating Method Reference Manual

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Goel, Supriya; Rosenberg, Michael I.

    This document is intended to be a reference manual for the Appendix G Performance Rating Method (PRM) of ANSI/ASHRAE/IES Standard 90.1- 2010 (Standard 90.1-2010).The PRM is used for rating the energy efficiency of commercial and high-rise residential buildings with designs that exceed the requirements of Standard 90.1. The procedures and processes described in this manual are designed to provide consistency and accuracy by filling in gaps and providing additional details needed by users of the PRM. It should be noted that this document is created independently from ASHRAE and SSPC 90.1 and is not sanctioned nor approved by either ofmore » those entities . Potential users of this manual include energy modelers, software developers and implementers of “beyond code” energy programs. Energy modelers using ASHRAE Standard 90.1-2010 for beyond code programs can use this document as a reference manual for interpreting requirements of the Performance Rating method. Software developers, developing tools for automated creation of the baseline model can use this reference manual as a guideline for developing the rules for the baseline model.« less

  12. Manual of industrial diamonds plus dressing and grinding criteria for machining superalloys

    NASA Technical Reports Server (NTRS)

    Carr, W. L.

    1968-01-01

    Manual combines the important and controlling factors for the proper selection and use of diamond stones for cutting and dressing grinding wheels. This manual is a compilation of empirical data and incorporates an original companion treatise on the physical descriptions of the diamond stones, their grading, and their applications.

  13. Students' Reactions to Manual-Based Treatments for Substance Abuse: An Exploratory Study

    ERIC Educational Resources Information Center

    Simons, Lori; Jacobucci, Raymond; Houston, Hank

    2006-01-01

    A quasi-experimental research design with quantitative and qualitative methodologies was conducted to explore reactions of 21 students to treatment manuals for substance abuse. Students were randomized to experimental (n = 11) and attention-control (n = 10) groups involving exposure to one of two manual-based therapy interventions. Quantitative…

  14. Inorganic Analyses in Water Quality Control Programs. Training Manual.

    ERIC Educational Resources Information Center

    Kroner, Audrey; And Others

    This lecture/laboratory manual for a five-day course deals with the analysis of selected inorganic pollutants. The manual is an instructional aid for classroom presentations to those with little or no experience in the field, but having one year (or equivalent) of college level inorganic chemistry, one semester of college level quantitative…

  15. Inorganic Analyses in Water Quality Control Programs. Training Manual.

    ERIC Educational Resources Information Center

    Office of Water Program Operations (EPA), Cincinnati, OH. National Training and Operational Technology Center.

    This document is a lecture/laboratory manual dealing with the analysis of selected inorganic pollutants. The manual is an instructional aid for classroom presentations to those with little or no experience in the field, but having one year (or equivalent) of college level inorganic chemistry and having basic laboratory skills. Topics include:…

  16. Biology Laboratory Safety Manual.

    ERIC Educational Resources Information Center

    Case, Christine L.

    The Centers for Disease Control (CDC) recommends that schools prepare or adapt a biosafety manual, and that instructors develop a list of safety procedures applicable to their own lab and distribute it to each student. In this way, safety issues will be brought to each student's attention. This document is an example of such a manual. It contains…

  17. Waste Water Plant Operators Manual.

    ERIC Educational Resources Information Center

    Washington State Coordinating Council for Occupational Education, Olympia.

    This manual for sewage treatment plant operators was prepared by a committee of operators, educators, and engineers for use as a reference text and handbook and to serve as a training manual for short course and certification programs. Sewage treatment plant operators have a responsibility in water quality control; they are the principal actors in…

  18. High‐resolution trench photomosaics from image‐based modeling: Workflow and error analysis

    USGS Publications Warehouse

    Reitman, Nadine G.; Bennett, Scott E. K.; Gold, Ryan D.; Briggs, Richard; Duross, Christopher

    2015-01-01

    Photomosaics are commonly used to construct maps of paleoseismic trench exposures, but the conventional process of manually using image‐editing software is time consuming and produces undesirable artifacts and distortions. Herein, we document and evaluate the application of image‐based modeling (IBM) for creating photomosaics and 3D models of paleoseismic trench exposures, illustrated with a case‐study trench across the Wasatch fault in Alpine, Utah. Our results include a structure‐from‐motion workflow for the semiautomated creation of seamless, high‐resolution photomosaics designed for rapid implementation in a field setting. Compared with conventional manual methods, the IBM photomosaic method provides a more accurate, continuous, and detailed record of paleoseismic trench exposures in approximately half the processing time and 15%–20% of the user input time. Our error analysis quantifies the effect of the number and spatial distribution of control points on model accuracy. For this case study, an ∼87  m2 exposure of a benched trench photographed at viewing distances of 1.5–7 m yields a model with <2  cm root mean square error (rmse) with as few as six control points. Rmse decreases as more control points are implemented, but the gains in accuracy are minimal beyond 12 control points. Spreading control points throughout the target area helps to minimize error. We propose that 3D digital models and corresponding photomosaics should be standard practice in paleoseismic exposure archiving. The error analysis serves as a guide for future investigations that seek balance between speed and accuracy during photomosaic and 3D model construction.

  19. The Smartphone Peer Physical Activity Counseling (SPPAC) Program for Manual Wheelchair Users: Protocol of a Pilot Randomized Controlled Trial

    PubMed Central

    Best, Krista L; Sweet, Shane N; Arbour-Nicitopoulos, Kelly P; Borisoff, Jaimie F; Noreau, Luc; Martin Ginis, Kathleen A

    2017-01-01

    Background Physical activity (PA) must be performed regularly to accrue health benefits. However, the majority of manual wheelchair users do not meet PA recommendations. Existing community-based PA programs for manual wheelchair users appear to work, but effect sizes are small and retention is low. Existing PA programs may not fully implement some psychosocial factors that are strongly linked with PA (eg, autonomy). The use of peers and mobile phone technology in the Smartphone Peer PA Counseling (SPPAC) program represents a novel approach to cultivating a PA-supportive environment for manual wheelchair users. Objective The primary objective is to compare change in objective PA between the experimental (SPPAC) and control groups from baseline to postintervention (10 weeks) and follow-up (3 months). Changes in and relationships between subjective PA, wheelchair skills, motivation, self-efficacy (for overcoming barriers to PA for manual wheelchair use), satisfaction of psychological needs for PA, and satisfaction with PA participation will be explored (secondary outcome). Program implementation will be explored (tertiary objective). Methods A total of 38 community-living manual wheelchair users (≥18 years) will be recruited in a randomized controlled trial (RCT). Participants in both the control and experimental groups will receive existing PA guidelines. Participants in the experimental group will also receive the SPPAC program: 14 sessions (~30 min) over a 10-week period delivered by a peer trainer using a mobile phone. PA activities will be based on individuals’ preferences and goals. Implementation of important theoretical variables will be enforced through a peer-trainer checklist. Outcomes for objective PA (primary) and subjective PA, wheelchair skills, motivation, self-efficacy, satisfaction of psychological needs, and satisfaction with participation will be collected at three time points (baseline, postintervention, follow-up). Multiple imputations will be used to treat missing data. A mixed-model ANCOVA will be conducted, controlling for covariates (primary and secondary objectives). The strength and direction of the relationships between the primary and secondary outcomes will be explored (secondary objective). Descriptive and content analysis will be used to appraise program implementation (tertiary objective). Results Funding has been obtained from the Craig Neilsen Foundation and the Canadian Disability Participation Project, with additional funds being sought from the Canadian Institute for Health Research and Fonds de Recherche du Québec-Santé. Pilot evaluation of intervention implementation is currently underway, with enrollment anticipated to begin early 2018. Conclusions There may be substantial benefits for the SPPAC program including limited burden on health care professionals, decreased barriers (eg. accessibility, transportation), development of peer social supports, and potential cost savings related to physical inactivity. Before conducting a large and expensive multisite RCT within a small heterogeneous population of manual wheelchair users, a pilot study affords a prudent step to establishing an adequate study protocol and implementation strategies. Trial Registration ClinicalTrials.gov NCT02826707; https://clinicaltrials.gov/ct2/show/NCT02826707 (Archived by WebCite at http://www.webcitation.org/6pqIc14dU) PMID:28446419

  20. LOCALIZING THE RANGELAND HEALTH METHOD FOR SOUTHEASTERN ARIZONA

    EPA Science Inventory

    The interagency manual Interpreting Indicators of Rangeland Health, Version 4 (Technical Reference 1734-6) provides a method for making rangeland health assessments. The manual recommends that the rangeland health assessment approach be adapted to local conditions. This technica...

Top