Sample records for manual control performance

  1. The effects of voice and manual control mode on dual task performance

    NASA Technical Reports Server (NTRS)

    Wickens, C. D.; Zenyuh, J.; Culp, V.; Marshak, W.

    1986-01-01

    Two fundamental principles of human performance, compatibility and resource competition, are combined with two structural dichotomies in the human information processing system, manual versus voice output, and left versus right cerebral hemisphere, in order to predict the optimum combination of voice and manual control with either hand, for time-sharing performance of a dicrete and continuous task. Eight right handed male subjected performed a discrete first-order tracking task, time-shared with an auditorily presented Sternberg Memory Search Task. Each task could be controlled by voice, or by the left or right hand, in all possible combinations except for a dual voice mode. When performance was analyzed in terms of a dual-task decrement from single task control conditions, the following variables influenced time-sharing efficiency in diminishing order of magnitude, (1) the modality of control, (discrete manual control of tracking was superior to discrete voice control of tracking and the converse was true with the memory search task), (2) response competition, (performance was degraded when both tasks were responded manually), (3) hemispheric competition, (performance degraded whenever two tasks were controlled by the left hemisphere) (i.e., voice or right handed control). The results confirm the value of predictive models invoice control implementation.

  2. Tele-Manipulation with Two Asymmetric Slaves: Two Operators Perform Better Than One.

    PubMed

    van Oosterhout, Jeroen; Heemskerk, Cock J M; de Baar, Marco R; van der Helm, Frans C T; Abbink, David A

    2018-01-01

    Certain tele-manipulation tasks require manipulation by two asymmetric slaves, for example, a crane for hoisting and a dexterous robotic arm for fine manipulation. It is unclear how to best design human-in-the-loop control over two asymmetric slaves. The goal of this paper is to quantitatively compare the standard approach of two co-operating operators that each control a single subtask, to a single operator performing bi-manual control over the two subtasks, and a uni-manual control approach. In a human factors experiment, participants performed a heavy load maneuvering and mounting task using a vertical crane and a robotic arm. We hypothesize that bi-manual control yields worse task performance and control activity compared to co-operation, because of conflicting spatial and temporal constraints. Literature suggests that uni-manual operators should perform better than co-operation, as co-operators critically depend on each other's actions. However, other literature provides evidence that individual operators have limited capabilities in controlling asymmetric axes of two dynamic systems. The results show that the two co-operators perform the maneuvering and mounting task faster than either bi- or uni-manual operators. Compared to co-operators, uni-manual operators required more control activity for the vertical crane and less for the robotic arm. In conclusion, this study suggests that when controlling two asymmetric slaves, a co-operating pair of operators performs better than a single operator.

  3. Proceedings of the Annual Conference on Manual Control (15th) held March 20 - 22, 1979, Wright State University, Dayton, Ohio

    DTIC Science & Technology

    1979-11-01

    Performance in a Precognitive Tracking Task," Proc. 13th Annual Conf. on Manual Control, pp. 152-165, June 1977. (32] Repa Brian S. and Robert S. Zucker...operators that have received attention in manual control. Precognitive manual control displays differ from the pursuit and compensatory displays of the

  4. Speech recognition in advanced rotorcraft - Using speech controls to reduce manual control overload

    NASA Technical Reports Server (NTRS)

    Vidulich, Michael A.; Bortolussi, Michael R.

    1988-01-01

    An experiment has been conducted to ascertain the usefulness of helicopter pilot speech controls and their effect on time-sharing performance, under the impetus of multiple-resource theories of attention which predict that time-sharing should be more efficient with mixed manual and speech controls than with all-manual ones. The test simulation involved an advanced, single-pilot scout/attack helicopter. Performance and subjective workload levels obtained supported the claimed utility of speech recognition-based controls; specifically, time-sharing performance was improved while preparing a data-burst transmission of information during helicopter hover.

  5. Annual Conference on Manual Control (20th) Held in California on June 12 - 14, 1984. Volume 1

    DTIC Science & Technology

    1984-06-14

    and in conjunction with movements of other joints. Much of this data is for atheletic performance . Components of such data can be simulated using JAMM... PERFORMANCE Chairman: Mr. Henry Jex Jewell, W. & Clement, W.F. A method for measuring the effective throughput time delay in simulated displays involving...manual control. 173 Allen, R. W. & DiMarco, R. J. Effects of transport delays on manual control system performance . 185 Sanders, K. E., Anderson, D. C

  6. Trust, control strategies and allocation of function in human-machine systems.

    PubMed

    Lee, J; Moray, N

    1992-10-01

    As automated controllers supplant human intervention in controlling complex systems, the operators' role often changes from that of an active controller to that of a supervisory controller. Acting as supervisors, operators can choose between automatic and manual control. Improperly allocating function between automatic and manual control can have negative consequences for the performance of a system. Previous research suggests that the decision to perform the job manually or automatically depends, in part, upon the trust the operators invest in the automatic controllers. This paper reports an experiment to characterize the changes in operators' trust during an interaction with a semi-automatic pasteurization plant, and investigates the relationship between changes in operators' control strategies and trust. A regression model identifies the causes of changes in trust, and a 'trust transfer function' is developed using time series analysis to describe the dynamics of trust. Based on a detailed analysis of operators' strategies in response to system faults we suggest a model for the choice between manual and automatic control, based on trust in automatic controllers and self-confidence in the ability to control the system manually.

  7. Proceedings, 13th Annual Conference on Manual Control

    NASA Technical Reports Server (NTRS)

    1977-01-01

    Theoretical aspects of manual control theory are discussed. Specific topics covered include: tracking; performance, attention allocation, and mental load; surface vehicle control; monitoring behavior and supervisory control; manipulators and prosthetics; aerospace vehicle control; motion and visual cues; and displays and controls.

  8. Effects of Retinal Eccentricity on Human Manual Control

    NASA Technical Reports Server (NTRS)

    Popovici, Alexandru; Zaal, Peter M. T.

    2017-01-01

    This study investigated the effects of viewing a primary flight display at different retinal eccentricities on human manual control behavior and performance. Ten participants performed a pitch tracking task while looking at a simplified primary flight display at different horizontal and vertical retinal eccentricities, and with two different controlled dynamics. Tracking performance declined at higher eccentricity angles and participants behaved more nonlinearly. The visual error rate gain increased with eccentricity for single-integrator-like controlled dynamics, but decreased for double-integrator-like dynamics. Participants' visual time delay was up to 100 ms higher at the highest horizontal eccentricity compared to foveal viewing. Overall, vertical eccentricity had a larger impact than horizontal eccentricity on most of the human manual control parameters and performance. Results might be useful in the design of displays and procedures for critical flight conditions such as in an aerodynamic stall.

  9. Speech versus manual control of camera functions during a telerobotic task

    NASA Technical Reports Server (NTRS)

    Bierschwale, John M.; Sampaio, Carlos E.; Stuart, Mark A.; Smith, Randy L.

    1989-01-01

    Voice input for control of camera functions was investigated in this study. Objective were to (1) assess the feasibility of a voice-commanded camera control system, and (2) identify factors that differ between voice and manual control of camera functions. Subjects participated in a remote manipulation task that required extensive camera-aided viewing. Each subject was exposed to two conditions, voice and manual input, with a counterbalanced administration order. Voice input was found to be significantly slower than manual input for this task. However, in terms of remote manipulator performance errors and subject preference, there was no difference between modalities. Voice control of continuous camera functions is not recommended. It is believed that the use of voice input for discrete functions, such as multiplexing or camera switching, could aid performance. Hybrid mixes of voice and manual input may provide the best use of both modalities. This report contributes to a better understanding of the issues that affect the design of an efficient human/telerobot interface.

  10. Architectural study of the design and operation of advanced force feedback manual controllers

    NASA Technical Reports Server (NTRS)

    Tesar, Delbert; Kim, Whee-Kuk

    1990-01-01

    A teleoperator system consists of a manual controller, control hardware/software, and a remote manipulator. It was employed in either hazardous or unstructured, and/or remote environments. In teleoperation, the main-in-the-loop is the central concept that brings human intelligence to the teleoperator system. When teleoperation involves contact with an uncertain environment, providing the feeling of telepresence to the human operator is one of desired characteristics of the teleoperator system. Unfortunately, most available manual controllers in bilateral or force-reflecting teleoperator systems can be characterized by their bulky size, high costs, or lack of smoothness and transparency, and elementary architectures. To investigate other alternatives, a force-reflecting, 3 degree of freedom (dof) spherical manual controller is designed, analyzed, and implemented as a test bed demonstration in this research effort. To achieve an improved level of design to meet criteria such as compactness, portability, and a somewhat enhanced force-reflecting capability, the demonstration manual controller employs high gear-ratio reducers. To reduce the effects of the inertia and friction on the system, various force control strategies are applied and their performance investigated. The spherical manual controller uses a parallel geometry to minimize inertial and gravitational effects on its primary task of transparent information transfer. As an alternative to the spherical 3-dof manual controller, a new conceptual (or parallel) spherical 3-dof module is introduced with a full kinematic analysis. Also, the resulting kinematic properties are compared to those of other typical spherical 3-dof systems. The conceptual design of a parallel 6-dof manual controller and its kinematic analysis is presented. This 6-dof manual controller is similar to the Stewart Platform with the actuators located on the base to minimize the dynamic effects. Finally, a combination of the new 3-dof and 6-dof concepts is presented as a feasible test-bed for enhanced performance in a 9-dof system.

  11. Motion Perception and Manual Control Performance During Passive Tilt and Translation Following Space Flight

    NASA Technical Reports Server (NTRS)

    Clement, Gilles; Wood, Scott J.

    2010-01-01

    This joint ESA-NASA study is examining changes in motion perception following Space Shuttle flights and the operational implications of post-flight tilt-translation ambiguity for manual control performance. Vibrotactile feedback of tilt orientation is also being evaluated as a countermeasure to improve performance during a closed-loop nulling task. METHODS. Data has been collected on 5 astronaut subjects during 3 preflight sessions and during the first 8 days after Shuttle landings. Variable radius centrifugation (216 deg/s) combined with body translation (12-22 cm, peak-to-peak) is utilized to elicit roll-tilt perception (equivalent to 20 deg, peak-to-peak). A forward-backward moving sled (24-390 cm, peak-to-peak) with or without chair tilting in pitch is utilized to elicit pitch tilt perception (equivalent to 20 deg, peak-to-peak). These combinations are elicited at 0.15, 0.3, and 0.6 Hz for evaluating the effect of motion frequency on tilt-translation ambiguity. In both devices, a closed-loop nulling task is also performed during pseudorandom motion with and without vibrotactile feedback of tilt. All tests are performed in complete darkness. PRELIMINARY RESULTS. Data collection is currently ongoing. Results to date suggest there is a trend for translation motion perception to be increased at the low and medium frequencies on landing day compared to pre-flight. Manual control performance is improved with vibrotactile feedback. DISCUSSION. The results of this study indicate that post-flight recovery of motion perception and manual control performance is complete within 8 days following short-duration space missions. Vibrotactile feedback of tilt improves manual control performance both before and after flight.

  12. WIM data analyst's manual

    DOT National Transportation Integrated Search

    2010-06-01

    This manual provides information and recommended procedures to be utilized by an agencys Weigh-in-Motion (WIM) Office Data Analyst to perform validation and quality control (QC) checks of WIM traffic data. This manual focuses on data generated by ...

  13. Speech versus manual control of camera functions during a telerobotic task

    NASA Technical Reports Server (NTRS)

    Bierschwale, John M.; Sampaio, Carlos E.; Stuart, Mark A.; Smith, Randy L.

    1993-01-01

    This investigation has evaluated the voice-commanded camera control concept. For this particular task, total voice control of continuous and discrete camera functions was significantly slower than manual control. There was no significant difference between voice and manual input for several types of errors. There was not a clear trend in subjective preference of camera command input modality. Task performance, in terms of both accuracy and speed, was very similar across both levels of experience.

  14. Regulation of dynamic postural control to attend manual steadiness constraints.

    PubMed

    Teixeira, Luis Augusto; Coutinho, Joane Figueiredo Serpa; Coelho, Daniel Boari

    2018-05-02

    In daily living activities, performance of spatially accurate manual movements in upright stance depends on postural stability. In the present investigation, we aimed to evaluate the effect of the required manual steadiness (task constraint) on the regulation of dynamic postural control. A single group of young participants (n=20) were evaluated in the performance of a dual posturo-manual task of balancing on a platform oscillating in sinusoidal translations at 0.4 Hz (low) or 1 Hz (high) frequencies while stabilizing a cylinder on a handheld tray. Manual task constraint was manipulated by comparing the conditions of keeping the cylinder stationary on its flat or round side, corresponding to low and high manual task constraints, respectively. Results showed that in the low oscillation frequency the high manual task constraint led to lower oscillation amplitudes of the head, center of mass, and tray, in addition to higher relative phase values between ankle/hip-shoulder oscillatory rotations and between center of mass/center of pressure-feet oscillations as compared to values observed in the low manual task constraint. Further analyses showed that the high manual task constraint also affected variables related to both postural (increased amplitudes of center of pressure oscillation) and manual (increased amplitude of shoulder rotations) task components in the high oscillation frequency. These results suggest that control of a dynamic posturo-manual task is modulated in distinct parameters to attend the required manual steadiness in a complex and flexible way.

  15. Study of automatic and manual terminal guidance and control systems for space shuttle vehicles. Volume 2: Section 4 through appendix B

    NASA Technical Reports Server (NTRS)

    Osder, S.; Keller, R.

    1971-01-01

    Guidance and control design studies that were performed for three specific space shuttle candidate vehicles are described. Three types of simulation were considered. The manual control investigations and pilot evaluations of the automatic system performance is presented. Recommendations for systems and equipment, both airborne and ground-based, necessary to flight test the guidance and control concepts for shuttlecraft terminal approach and landing are reported.

  16. Comparison of characteristics of femtosecond laser-assisted anterior capsulotomy versus manual continuous curvilinear capsulorrhexis: A meta-analysis of 5-year results.

    PubMed

    Ali, Muhammad Hassaan; Ullah, Samee; Javaid, Usman; Javaid, Mamoona; Jamal, Samreen; Butt, Nadeem Hafeez

    2017-10-01

    To perform a meta-analysis on the precision and safety of femtosecond laser-assisted anterior capsulotomy versus conventional manual continuous curvilinear capsulorrhexis. This meta-analysis was conducted from February 2010 to November 2014. Literature search on PubMed, Google Scholar, ExcerptaMedica database and Cochrane Library was done to identify randomised controlled trials and case-control studies. SPSS 20 was used for data analysis. Of the 10 articles included, there were 3(30%) randomised controlled trials and 7(70%) non-randomised controlled trials. The meta-analysis was based on a total of 2,882eyes. Of them, 1,498(51.97%) underwent femtosecond laser-assisted capsulotomy and 1,384(48.02%) underwent manual continuous curvilinear capsulorrhexis. The diameter of the capsulotomy and the rates of anterior capsule tear showed no statistical difference between the femtosecond laser group and the manual capsulorrhexis group (p=0.29 and p=0.68). In terms of circularity of capsulotomy, femtosecond laser group had a more significant advantage than the manual capsulorrhexis group (p<0.001). Femtosecond laser performed capsulotomy with more precision and higher reliability than the manual continuous curvilinear capsulorrhexis.

  17. Navy Occupational Health Information Management System (NOHIMS). Hazardous Materials Control Module. Users’ Manual

    DTIC Science & Technology

    1987-01-16

    Occupational Health Information Management System (NOHIMS) 6 Hazardous Materials Control Module (HMC) User’s Manual 7. Author(s) 8. Performing Organization...Materials Control (HMC) module of the Naval Medical Command’s (NAVMED) Navy Occupational Health Information Management System (NOHIMS). After presenting

  18. Sharing control with haptics: seamless driver support from manual to automatic control.

    PubMed

    Mulder, Mark; Abbink, David A; Boer, Erwin R

    2012-10-01

    Haptic shared control was investigated as a human-machine interface that can intuitively share control between drivers and an automatic controller for curve negotiation. As long as automation systems are not fully reliable, a role remains for the driver to be vigilant to the system and the environment to catch any automation errors. The conventional binary switches between supervisory and manual control has many known issues, and haptic shared control is a promising alternative. A total of 42 respondents of varying age and driving experience participated in a driving experiment in a fixed-base simulator, in which curve negotiation behavior during shared control was compared to during manual control, as well as to three haptic tunings of an automatic controller without driver intervention. Under the experimental conditions studied, the main beneficial effect of haptic shared control compared to manual control was that less control activity (16% in steering wheel reversal rate, 15% in standard deviation of steering wheel angle) was needed for realizing an improved safety performance (e.g., 11% in peak lateral error). Full automation removed the need for any human control activity and improved safety performance (e.g., 35% in peak lateral error) but put the human in a supervisory position. Haptic shared control kept the driver in the loop, with enhanced performance at reduced control activity, mitigating the known issues that plague full automation. Haptic support for vehicular control ultimately seeks to intuitively combine human intelligence and creativity with the benefits of automation systems.

  19. Optimizing the balance between task automation and human manual control in simulated submarine track management.

    PubMed

    Chen, Stephanie I; Visser, Troy A W; Huf, Samuel; Loft, Shayne

    2017-09-01

    Automation can improve operator performance and reduce workload, but can also degrade operator situation awareness (SA) and the ability to regain manual control. In 3 experiments, we examined the extent to which automation could be designed to benefit performance while ensuring that individuals maintained SA and could regain manual control. Participants completed a simulated submarine track management task under varying task load. The automation was designed to facilitate information acquisition and analysis, but did not make task decisions. Relative to a condition with no automation, the continuous use of automation improved performance and reduced subjective workload, but degraded SA. Automation that was engaged and disengaged by participants as required (adaptable automation) moderately improved performance and reduced workload relative to no automation, but degraded SA. Automation engaged and disengaged based on task load (adaptive automation) provided no benefit to performance or workload, and degraded SA relative to no automation. Automation never led to significant return-to-manual deficits. However, all types of automation led to degraded performance on a nonautomated task that shared information processing requirements with automated tasks. Given these outcomes, further research is urgently required to establish how to design automation to maximize performance while keeping operators cognitively engaged. (PsycINFO Database Record (c) 2017 APA, all rights reserved).

  20. The retention of manual flying skills in the automated cockpit.

    PubMed

    Casner, Stephen M; Geven, Richard W; Recker, Matthias P; Schooler, Jonathan W

    2014-12-01

    The aim of this study was to understand how the prolonged use of cockpit automation is affecting pilots' manual flying skills. There is an ongoing concern about a potential deterioration of manual flying skills among pilots who assume a supervisory role while cockpit automation systems carry out tasks that were once performed by human pilots. We asked 16 airline pilots to fly routine and nonroutine flight scenarios in a Boeing 747-400 simulator while we systematically varied the level of automation that they used, graded their performance, and probed them about what they were thinking about as they flew. We found pilots' instrument scanning and manual control skills to be mostly intact, even when pilots reported that they were infrequently practiced. However, when pilots were asked to manually perform the cognitive tasks needed for manual flight (e.g., tracking the aircraft's position without the use of a map display, deciding which navigational steps come next, recognizing instrument system failures), we observed more frequent and significant problems. Furthermore, performance on these cognitive tasks was associated with measures of how often pilots engaged in task-unrelated thought when cockpit automation was used. We found that while pilots' instrument scanning and aircraft control skills are reasonably well retained when automation is used, the retention of cognitive skills needed for manual flying may depend on the degree to which pilots remain actively engaged in supervising the automation.

  1. 33 CFR 385.3 - Definitions.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... performance of the Central and Southern Project and other water management systems in the South Florida... locations and times. Natural system means all land and water managed by the Federal government or the State... System Operating Manual and Project Operating Manuals. Operating Manuals contain water control plans...

  2. 33 CFR 385.3 - Definitions.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... performance of the Central and Southern Project and other water management systems in the South Florida... locations and times. Natural system means all land and water managed by the Federal government or the State... System Operating Manual and Project Operating Manuals. Operating Manuals contain water control plans...

  3. Driving Performance After Self-Regulated Control Transitions in Highly Automated Vehicles.

    PubMed

    Eriksson, Alexander; Stanton, Neville A

    2017-12-01

    This study aims to explore whether driver-paced, noncritical transitions of control may counteract some of the aftereffects observed in the contemporary literature, resulting in higher levels of vehicle control. Research into control transitions in highly automated driving has focused on urgent scenarios where drivers are given a relatively short time span to respond to a request to resume manual control, resulting in seemingly scrambled control when manual control is resumed. Twenty-six drivers drove two scenarios with an automated driving feature activated. Drivers were asked to read a newspaper or monitor the system and relinquish or resume control from the automation when prompted by vehicle systems. Driving performance in terms of lane positioning and steering behavior was assessed for 20 seconds post resuming control to capture the resulting level of control. It was found that lane positioning was virtually unaffected for the duration of the 20-second time span in both automated conditions compared to the manual baseline when drivers resumed manual control; however, significant increases in the standard deviation of steering input were found for both automated conditions compared to baseline. No significant differences were found between the two automated conditions. The results indicate that when drivers self-paced the transfer back to manual control they exhibit less of the detrimental effects observed in system-paced conditions. It was shown that self-paced transitions could reduce the risk of accidents near the edge of the operational design domain. Vehicle manufacturers must consider these benefits when designing contemporary systems.

  4. Influence of Vibrotactile Feedback on Controlling Tilt Motion After Spaceflight

    NASA Technical Reports Server (NTRS)

    Wood, S. J.; Rupert, A. H.; Vanya, R. D.; Esteves, J. T.; Clement, G.

    2011-01-01

    We hypothesize that adaptive changes in how inertial cues from the vestibular system are integrated with other sensory information leads to perceptual disturbances and impaired manual control following transitions between gravity environments. The primary goals of this ongoing post-flight investigation are to quantify decrements in manual control of tilt motion following short-duration spaceflight and to evaluate vibrotactile feedback of tilt as a sensorimotor countermeasure. METHODS. Data is currently being collected on 9 astronaut subjects during 3 preflight sessions and during the first 8 days after Shuttle landings. Variable radius centrifugation (216 deg/s, <20 cm radius) in a darkened room is utilized to elicit otolith reflexes in the lateral plane without concordant canal or visual cues. A Tilt-Translation Sled (TTS) is capable of synchronizing pitch tilt with fore-aft translation to align the resultant gravitoinertial vector with the longitudinal body axis, thereby eliciting canal reflexes without concordant otolith or visual cues. A simple 4 tactor system was implemented to provide feedback when tilt position exceeded predetermined levels in either device. Closed-loop nulling tasks are performed during random tilt steps or sum-of-sines (TTS only) with and without vibrotactile feedback of chair position. RESULTS. On landing day the manual control performance without vibrotactile feedback was reduced by >30% based on the gain or the amount of tilt disturbance successfully nulled. Manual control performance tended to return to baseline levels within 1-2 days following landing. Root-mean-square position error and tilt velocity were significantly reduced with vibrotactile feedback. CONCLUSIONS. These preliminary results are consistent with our hypothesis that adaptive changes in vestibular processing corresponds to reduced manual control performance following G-transitions. A simple vibrotactile prosthesis improves the ability to null out tilt motion within a limited range of motion disturbances.

  5. SRB-3D Solid Rocket Booster performance prediction program. Volume 3: Programmer's manual

    NASA Technical Reports Server (NTRS)

    Winkler, J. C.

    1976-01-01

    The programmer's manual for the Modified Solid Rocket Booster Performance Prediction Program (SRB-3D) describes the major control routines of SRB-3D, followed by a super index listing of the program and a cross-reference of the program variables.

  6. Effects of Selected Task Performance Criteria at Initiating Adaptive Task Real locations

    NASA Technical Reports Server (NTRS)

    Montgomery, Demaris A.

    2001-01-01

    In the current report various performance assessment methods used to initiate mode transfers between manual control and automation for adaptive task reallocation were tested. Participants monitored two secondary tasks for critical events while actively controlling a process in a fictional system. One of the secondary monitoring tasks could be automated whenever operators' performance was below acceptable levels. Automation of the secondary task and transfer of the secondary task back to manual control were either human- or machine-initiated. Human-initiated transfers were based on the operator's assessment of the current task demands while machine-initiated transfers were based on the operators' performance. Different performance assessment methods were tested in two separate experiments.

  7. The effects of bedrest on crew performance during simulated shuttle reentry. Volume 2: Control task performance

    NASA Technical Reports Server (NTRS)

    Jex, H. R.; Peters, R. A.; Dimarco, R. J.; Allen, R. W.

    1974-01-01

    A simplified space shuttle reentry simulation performed on the NASA Ames Research Center Centrifuge is described. Anticipating potentially deleterious effects of physiological deconditioning from orbital living (simulated here by 10 days of enforced bedrest) upon a shuttle pilot's ability to manually control his aircraft (should that be necessary in an emergency) a comprehensive battery of measurements was made roughly every 1/2 minute on eight military pilot subjects, over two 20-minute reentry Gz vs. time profiles, one peaking at 2 Gz and the other at 3 Gz. Alternate runs were made without and with g-suits to test the help or interference offered by such protective devices to manual control performance. A very demanding two-axis control task was employed, with a subcritical instability in the pitch axis to force a high attentional demand and a severe loss-of-control penalty. The results show that pilots experienced in high Gz flying can easily handle the shuttle manual control task during 2 Gz or 3 Gz reentry profiles, provided the degree of physiological deconditioning is no more than induced by these 10 days of enforced bedrest.

  8. Skylab Saturn 1B flight manual

    NASA Technical Reports Server (NTRS)

    1972-01-01

    A Saturn 1B Flight Manual provides launch vehicle systems descriptions and predicted performance data for the Skylab missions. Vehicle SL-2 (SA-206) is the baseline for this manual; but, as a result of the great similarity, the material is representative of SL-3 and SL-4 launch vehicles, also. The Flight Manual is not a control document but is intended primarily as an aid to astronauts who are training for Skylab missions. In order to provide a comprehensive reference for that purpose, the manual also contains descriptions of the ground support interfaces, prelaunch operations, and emergency procedures. Mission variables and constraints are summarized, and mission control monitoring and data flow during launch preparation and flight are discussed.

  9. Applying Computer Models to Realize Closed-Loop Neonatal Oxygen Therapy.

    PubMed

    Morozoff, Edmund; Smyth, John A; Saif, Mehrdad

    2017-01-01

    Within the context of automating neonatal oxygen therapy, this article describes the transformation of an idea verified by a computer model into a device actuated by a computer model. Computer modeling of an entire neonatal oxygen therapy system can facilitate the development of closed-loop control algorithms by providing a verification platform and speeding up algorithm development. In this article, we present a method of mathematically modeling the system's components: the oxygen transport within the patient, the oxygen blender, the controller, and the pulse oximeter. Furthermore, within the constraints of engineering a product, an idealized model of the neonatal oxygen transport component may be integrated effectively into the control algorithm of a device, referred to as the adaptive model. Manual and closed-loop oxygen therapy performance were defined in this article by 3 criteria in the following order of importance: percent duration of SpO2 spent in normoxemia (target SpO2 ± 2.5%), hypoxemia (less than normoxemia), and hyperoxemia (more than normoxemia); number of 60-second periods <85% SpO2 and >95% SpO2; and number of manual adjustments. Results from a clinical evaluation that compared the performance of 3 closed-loop control algorithms (state machine, proportional-integral-differential, and adaptive model) with manual oxygen therapy on 7 low-birth-weight ventilated preterm babies, are presented. Compared with manual therapy, all closed-loop control algorithms significantly increased the patients' duration in normoxemia and reduced hyperoxemia (P < 0.05). The number of manual adjustments was also significantly reduced by all of the closed-loop control algorithms (P < 0.05). Although the performance of the 3 control algorithms was equivalent, it is suggested that the adaptive model, with its ease of use, may have the best utility.

  10. Automation - Changes in cognitive demands and mental workload

    NASA Technical Reports Server (NTRS)

    Tsang, Pamela S.; Johnson, Walter W.

    1987-01-01

    The effect of partial automation on mental workloads in man/machine tasks is investigated experimentally. Subjective workload measures are obtained from six subjects after performance of a task battery comprising two manual (flight-path control, FC, and target acquisition, TA) tasks and one decisionmaking (engine failure, EF) task; the FC task was performed in both a fully manual (altitude and lateral control) mode and in a semiautomated mode (autmatic latitude control). The performance results and subjective evaluations are presented in graphs and characterized in detail. The automation is shown to improve objective performance and lower subjective workload significantly in the combined FC/TA task, but not in the FC task alone or in the FC/EF task.

  11. The effect of processing code, response modality and task difficulty on dual task performance and subjective workload in a manual system

    NASA Technical Reports Server (NTRS)

    Liu, Yili; Wickens, Christopher D.

    1987-01-01

    This paper reports on the first experiment of a series studying the effect of task structure and difficulty demand on time-sharing performance and workload in both automated and corresponding manual systems. The experimental task involves manual control time-shared with spatial and verbal decisions tasks of two levels of difficulty and two modes of response (voice or manual). The results provide strong evidence that tasks and processes competing for common processing resources are time shared less effecively and have higher workload than tasks competing for separate resources. Subjective measures and the structure of multiple resources are used in conjunction to predict dual task performance. The evidence comes from both single-task and from dual-task performance.

  12. Influence of Coactors on Saccadic and Manual Responses

    PubMed Central

    Niehorster, Diederick C.; Jarodzka, Halszka; Holmqvist, Kenneth

    2017-01-01

    Two experiments were conducted to investigate the effects of coaction on saccadic and manual responses. Participants performed the experiments either in a solitary condition or in a group of coactors who performed the same tasks at the same time. In Experiment 1, participants completed a pro- and antisaccade task where they were required to make saccades towards (prosaccades) or away (antisaccades) from a peripheral visual stimulus. In Experiment 2, participants performed a visual discrimination task that required both making a saccade towards a peripheral stimulus and making a manual response in reaction to the stimulus’s orientation. The results showed that performance of stimulus-driven responses was independent of the social context, while volitionally controlled responses were delayed by the presence of coactors. These findings are in line with studies assessing the effect of attentional load on saccadic control during dual-task paradigms. In particular, antisaccades – but not prosaccades – were influenced by the type of social context. Additionally, the number of coactors present in the group had a moderating effect on both saccadic and manual responses. The results support an attentional view of social influences. PMID:28321288

  13. Comparison of a brain-based adaptive system and a manual adaptable system for invoking automation.

    PubMed

    Bailey, Nathan R; Scerbo, Mark W; Freeman, Frederick G; Mikulka, Peter J; Scott, Lorissa A

    2006-01-01

    Two experiments are presented examining adaptive and adaptable methods for invoking automation. Empirical investigations of adaptive automation have focused on methods used to invoke automation or on automation-related performance implications. However, no research has addressed whether performance benefits associated with brain-based systems exceed those in which users have control over task allocations. Participants performed monitoring and resource management tasks as well as a tracking task that shifted between automatic and manual modes. In the first experiment, participants worked with an adaptive system that used their electroencephalographic signals to switch the tracking task between automatic and manual modes. Participants were also divided between high- and low-reliability conditions for the system-monitoring task as well as high- and low-complacency potential. For the second experiment, participants operated an adaptable system that gave them manual control over task allocations. Results indicated increased situation awareness (SA) of gauge instrument settings for individuals high in complacency potential using the adaptive system. In addition, participants who had control over automation performed more poorly on the resource management task and reported higher levels of workload. A comparison between systems also revealed enhanced SA of gauge instrument settings and decreased workload in the adaptive condition. The present results suggest that brain-based adaptive automation systems may enhance perceptual level SA while reducing mental workload relative to systems requiring user-initiated control. Potential applications include automated systems for which operator monitoring performance and high-workload conditions are of concern.

  14. The internal model: A study of the relative contribution of proprioception and visual information to failure detection in dynamic systems. [sensitivity of operators versus monitors to failures

    NASA Technical Reports Server (NTRS)

    Kessel, C.; Wickens, C. D.

    1978-01-01

    The development of the internal model as it pertains to the detection of step changes in the order of control dynamics is investigated for two modes of participation: whether the subjects are actively controlling those dynamics or are monitoring an autopilot controlling them. A transfer of training design was used to evaluate the relative contribution of proprioception and visual information to the overall accuracy of the internal model. Sixteen subjects either tracked or monitored the system dynamics as a 2-dimensional pursuit display under single task conditions and concurrently with a sub-critical tracking task at two difficulty levels. Detection performance was faster and more accurate in the manual as opposed to the autopilot mode. The concurrent tracking task produced a decrement in detection performance for all conditions though this was more marked for the manual mode. The development of an internal model in the manual mode transferred positively to the automatic mode producing enhanced detection performance. There was no transfer from the internal model developed in the automatic mode to the manual mode.

  15. Manned versus unmanned rendezvous and capture

    NASA Technical Reports Server (NTRS)

    Brody, Adam R.

    1991-01-01

    Rendezvous and capture (docking) operations may be performed either automatically or under manual control. In cases where humans are far from the mission site, or high-bandwidth communications lines are not in place, automation is the only option. Such might be the case with unmanned missions to the moon or Mars that involve orbital docking or cargo transfer. In crewed situations where sensors, computation capabilities, and other necessary instrumentation are unavailable, manual control is the only alternative. Power, mass, cost, or other restrictions may limit the availability of the machinery required for an automated rendezvous and capture. The only occasions for which there is a choice about whether to use automated or manual control are those where the vehicle(s) have both the crew and instrumentation necessary to perform the mission either way. The following discussion will focus on the final approach or capture (docking) maneuver. The maneuvers required for long-range rendezvous operations are calculated by computers. It is almost irrelevant whether it is an astronaut, watching a count-down timer who pushes the button firing the thruster or whether the computer keeps track of the time and fires with the astronaut monitoring. The actual manual workload associated with a mission that may take as long as hours or days to perform is small. The workload per unit time increases tremendously during the final approach (docking) phase and this is where the issue of manual versus automatic is more important.

  16. Manual and automatic flight control during severe turbulence penetration

    NASA Technical Reports Server (NTRS)

    Johnston, D. E.; Klein, R. H.; Hoh, R. H.

    1976-01-01

    An analytical and experimental investigation of possible contributing factors in jet aircraft turbulence upsets was conducted. Major contributing factors identified included autopilot and display deficiencies, the large aircraft inertia and associated long response time, and excessive pilot workload. An integrated flight and thrust energy management director system was synthesized. The system was incorporated in a moving-base simulation and evaluated using highly experienced airline pilots. The evaluation included comparison of pilot workload and flight performance during severe turbulence penetration utilizing four control/display concepts: manual control with conventional full panel display, conventional autopilot (A/P-A) with conventional full panel display, improved autopilot (A/P-B) with conventional full panel display plus thrust director display, and longitudinal flight director with conventional full panel display plus thrust director display. Simulation results show improved performance, reduced pilot workload, and a pilot preference for the autopilot system controlling to the flight director command and manual control of thrust following the trim thrust director.

  17. Emergency Manuals Improved Novice Physician Performance During Simulated ICU Emergencies

    PubMed Central

    Wang, Jacob; Stiegler, Marjorie P.; Nguyen, Dung; Rebel, Annette; Isaak, Robert S.

    2017-01-01

    Background Emergency manuals, which are safety essentials in non-medical high-reliability organizations (e.g., aviation), have recently gained acceptance in critical medical environments. Of the existing emergency manuals in anesthesiology, most are geared towards intraoperative settings. Additionally, most evidence supporting their efficacy focuses on the study of physicians with at least some meaningful experience as a physician. Our aim was to evaluate whether an emergency manual would improve the performance of novice physicians (post-graduate year [PGY] 1 or first year resident) in managing a critical event in the intensive care unit (ICU). Methods PGY1 interns (n=41) were assessed on the management of a simulated critical event (unstable bradycardia) in the ICU. Participants underwent a group allocation process to either a control group (n=18) or an intervention group (emergency manual provided, n=23). The number of successfully executed treatment and diagnostic interventions completed was evaluated over a ten minute (600 seconds) simulation for each participant. Results The participants using the emergency manual averaged 9.9/12 (83%) interventions, compared to an average of 7.1/12 (59%) interventions (p < 0.01) in the control group. Conclusions The use of an emergency manual was associated with a significant improvement in critical event management by individual novice physicians in a simulated ICU patient (23% average increase). PMID:29600255

  18. Emergency Manuals Improved Novice Physician Performance During Simulated ICU Emergencies.

    PubMed

    Kazior, Michael R; Wang, Jacob; Stiegler, Marjorie P; Nguyen, Dung; Rebel, Annette; Isaak, Robert S

    2017-01-01

    Emergency manuals, which are safety essentials in non-medical high-reliability organizations (e.g., aviation), have recently gained acceptance in critical medical environments. Of the existing emergency manuals in anesthesiology, most are geared towards intraoperative settings. Additionally, most evidence supporting their efficacy focuses on the study of physicians with at least some meaningful experience as a physician. Our aim was to evaluate whether an emergency manual would improve the performance of novice physicians (post-graduate year [PGY] 1 or first year resident) in managing a critical event in the intensive care unit (ICU). PGY1 interns (n=41) were assessed on the management of a simulated critical event (unstable bradycardia) in the ICU. Participants underwent a group allocation process to either a control group (n=18) or an intervention group (emergency manual provided, n=23). The number of successfully executed treatment and diagnostic interventions completed was evaluated over a ten minute (600 seconds) simulation for each participant. The participants using the emergency manual averaged 9.9/12 (83%) interventions, compared to an average of 7.1/12 (59%) interventions (p < 0.01) in the control group. The use of an emergency manual was associated with a significant improvement in critical event management by individual novice physicians in a simulated ICU patient (23% average increase).

  19. Flight investigation of manual and automatic VTOL decelerating instrument approaches and landings

    NASA Technical Reports Server (NTRS)

    Kelly, J. R.; Niessen, F. R.; Thibodeaux, J. J.; Yenni, K. R.; Garren, J. F., Jr.

    1974-01-01

    A flight investigation was undertaken to study the problems associated with manual and automatic control of steep, decelerating instrument approaches and landings under simulated instrument conditions. The study was conducted with a research helicopter equipped with a three-cue flight-director indicator. The scope of the investigation included variations in the flight-director control laws, glide-path angle, deceleration profile, and control response characteristics. Investigation of the automatic-control problem resulted in the first automated approach and landing to a predetermined spot ever accomplished with a helicopter. Although well-controlled approaches and landings could be performed manually with the flight-director concept, pilot comments indicated the need for a better display which would more effectively integrate command and situation information.

  20. Real-Time Performance Feedback for the Manual Control of Spacecraft

    NASA Astrophysics Data System (ADS)

    Karasinski, John Austin

    Real-time performance metrics were developed to quantify workload, situational awareness, and manual task performance for use as visual feedback to pilots of aerospace vehicles. Results from prior lunar lander experiments with variable levels of automation were replicated and extended to provide insights for the development of real-time metrics. Increased levels of automation resulted in increased flight performance, lower workload, and increased situational awareness. Automated Speech Recognition (ASR) was employed to detect verbal callouts as a limited measure of subjects' situational awareness. A one-dimensional manual tracking task and simple instructor-model visual feedback scheme was developed. This feedback was indicated to the operator by changing the color of a guidance element on the primary flight display, similar to how a flight instructor points out elements of a display to a student pilot. Experiments showed that for this low-complexity task, visual feedback did not change subject performance, but did increase the subjects' measured workload. Insights gained from these experiments were applied to a Simplified Aid for EVA Rescue (SAFER) inspection task. The effects of variations of an instructor-model performance-feedback strategy on human performance in a novel SAFER inspection task were investigated. Real-time feedback was found to have a statistically significant effect of improving subject performance and decreasing workload in this complicated four degree of freedom manual control task with two secondary tasks.

  1. Evaluation of three automatic oxygen therapy control algorithms on ventilated low birth weight neonates.

    PubMed

    Morozoff, Edmund P; Smyth, John A

    2009-01-01

    Neonates with under developed lungs often require oxygen therapy. During the course of oxygen therapy, elevated levels of blood oxygenation, hyperoxemia, must be avoided or the risk of chronic lung disease or retinal damage is increased. Low levels of blood oxygen, hypoxemia, may lead to permanent brain tissue damage and, in some cases, mortality. A closed loop controller that automatically administers oxygen therapy using 3 algorithms - state machine, adaptive model, and proportional integral derivative (PID) - is applied to 7 ventilated low birth weight neonates and compared to manual oxygen therapy. All 3 automatic control algorithms demonstrated their ability to improve manual oxygen therapy by increasing periods of normoxemia and reducing the need for manual FiO(2) adjustments. Of the three control algorithms, the adaptive model showed the best performance with 0.25 manual adjustments per hour and 73% time spent within target +/- 3% SpO(2).

  2. System Hazard Analysis of TACOM’s Crew Station/Turret Motion Base Simulator

    DTIC Science & Technology

    1992-01-01

    Safety devices have been located on the equipment where necessary and are described in the Contraves USA Manual No. IM-27751, "INSTRUCTION MANUAL FOR...OF TACOM’s CREW STATION/TURRET MOTION BASE SIMULATOR" and Contraves USA Manual No. IM-27751, "INSTRUCTION MANUAL FOR TACOM" in an attempt to satisfy... Contraves USA and assembled jointly by Contraves USA and TACOM. All control compensation was performed by TACOM. The CS/TMBS is expected to open doors

  3. Automatic sample changer control software for automation of neutron activation analysis process in Malaysian Nuclear Agency

    NASA Astrophysics Data System (ADS)

    Yussup, N.; Ibrahim, M. M.; Rahman, N. A. A.; Mokhtar, M.; Salim, N. A. A.; Soh@Shaari, S. C.; Azman, A.; Lombigit, L.; Azman, A.; Omar, S. A.

    2018-01-01

    Most of the procedures in neutron activation analysis (NAA) process that has been established in Malaysian Nuclear Agency (Nuclear Malaysia) since 1980s were performed manually. These manual procedures carried out by the NAA laboratory personnel are time consuming and inefficient especially for sample counting and measurement process. The sample needs to be changed and the measurement software needs to be setup for every one hour counting time. Both of these procedures are performed manually for every sample. Hence, an automatic sample changer system (ASC) that consists of hardware and software is developed to automate sample counting process for up to 30 samples consecutively. This paper describes the ASC control software for NAA process which is designed and developed to control the ASC hardware and call GammaVision software for sample measurement. The software is developed by using National Instrument LabVIEW development package.

  4. Solving the optimal attention allocation problem in manual control

    NASA Technical Reports Server (NTRS)

    Kleinman, D. L.

    1976-01-01

    Within the context of the optimal control model of human response, analytic expressions for the gradients of closed-loop performance metrics with respect to human operator attention allocation are derived. These derivatives serve as the basis for a gradient algorithm that determines the optimal attention that a human should allocate among several display indicators in a steady-state manual control task. Application of the human modeling techniques are made to study the hover control task for a CH-46 VTOL flight tested by NASA.

  5. Controlling robots in the home: Factors that affect the performance of novice robot operators.

    PubMed

    McGinn, Conor; Sena, Aran; Kelly, Kevin

    2017-11-01

    For robots to successfully integrate into everyday life, it is important that they can be effectively controlled by laypeople. However, the task of manually controlling mobile robots can be challenging due to demanding cognitive and sensorimotor requirements. This research explores the effect that the built environment has on the manual control of domestic service robots. In this study, a virtual reality simulation of a domestic robot control scenario was developed. The performance of fifty novice users was evaluated, and their subjective experiences recorded through questionnaires. Through quantitative and qualitative analysis, it was found that untrained operators frequently perform poorly at navigation-based robot control tasks. The study found that passing through doorways accounted for the largest number of collisions, and was consistently identified as a very difficult operation to perform. These findings suggest that homes and other human-orientated settings present significant challenges to robot control. Copyright © 2017 Elsevier Ltd. All rights reserved.

  6. Aerial applications dispersal systems control requirements study. [agriculture

    NASA Technical Reports Server (NTRS)

    Bauchspies, J. S.; Cleary, W. L.; Rogers, W. F.; Simpson, W.; Sanders, G. S.

    1980-01-01

    Performance deficiencies in aerial liquid and dry dispersal systems are identified. Five control system concepts are explored: (1) end of field on/off control; (2) manual control of particle size and application rate from the aircraft; (3) manual control of deposit rate on the field; (4) automatic alarm and shut-off control; and (5) fully automatic control. Operational aspects of the concepts and specifications for improved control configurations are discussed in detail. A research plan to provide the technology needed to develop the proposed improvements is presented along with a flight program to verify the benefits achieved.

  7. A simulation study of emergency lunar escape to orbit using several simplified manual guidance and control techniques

    NASA Technical Reports Server (NTRS)

    Middleton, D. B.; Hurt, G. J., Jr.

    1971-01-01

    A fixed-base piloted simulator investigation has been made of the feasibility of using any of several manual guidance and control techniques for emergency lunar escape to orbit with very simplified, lightweight vehicle systems. The escape-to-orbit vehicles accommodate two men, but one man performs all of the guidance and control functions. Three basic attitude-control modes and four manually executed trajectory-guidance schemes were used successfully during approximately 125 simulated flights under a variety of conditions. These conditions included thrust misalinement, uneven propellant drain, and a vehicle moment-of-inertia range of 250 to 12,000 slugs per square foot. Two types of results are presented - orbit characteristics and pilot ratings of vehicle handling qualities.

  8. A low cost, high performance remotely controlled backhoe/excavator

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Rizzo, J.

    1995-12-31

    This paper addresses a state of the art, low cost, remotely controlled backhoe/excavator system for remediation use at hazardous waste sites. The all weather, all terrain, Remote Dig-It is based on a simple, proven construction platform and incorporates state of the art sensors, control, telemetry and other subsystems derived from advanced underwater remotely operated vehicle systems. The system can be towed to a site without the use of a trailer, manually operated by an on board operator or operated via a fiber optic or optional RF communications link by a remotely positioned operator. A proportional control system is piggy backedmore » onto the standard manual control system. The control system improves manual operation, allows rapid manual/remote mode selection and provides fine manual or remote control of all functions. The system incorporates up to 4 separate video links, acoustic obstacle proximity sensors, and stereo audio pickups and an optional differential GPS navigation. Video system options include electronic panning and tilting within a distortion-corrected wide angle field of view. The backhoe/excavator subsystem has a quick disconnect interface feature which allows its use as a manipulator with a wide variety of end effectors and tools. The Remote Dig-It was developed to respond to the need for a low-cost, effective remediation system for use at sites containing hazardous materials. The prototype system was independently evaluated for this purpose by the Army at the Jefferson Proving Ground where it surpassed all performance goals. At the time of this writing, the Remote Dig-It system is currently the only backhoe/excavator which met the Army`s goals for remediation systems for use at hazardous waste sites and it costs a fraction of any known competing offerings.« less

  9. Manual control age and sex differences in 4 to 11 year old children.

    PubMed

    Flatters, Ian; Hill, Liam J B; Williams, Justin H G; Barber, Sally E; Mon-Williams, Mark

    2014-01-01

    To what degree does being male or female influence the development of manual skills in pre-pubescent children? This question is important because of the emphasis placed on developing important new manual skills during this period of a child's education (e.g. writing, drawing, using computers). We investigated age and sex-differences in the ability of 422 children to control a handheld stylus. A task battery deployed using tablet PC technology presented interactive visual targets on a computer screen whilst simultaneously recording participant's objective kinematic responses, via their interactions with the on-screen stimuli using the handheld stylus. The battery required children use the stylus to: (i) make a series of aiming movements, (ii) trace a series of abstract shapes and (iii) track a moving object. The tasks were not familiar to the children, allowing measurement of a general ability that might be meaningfully labelled 'manual control', whilst minimising culturally determined differences in experience (as much as possible). A reliable interaction between sex and age was found on the aiming task, with girls' movement times being faster than boys in younger age groups (e.g. 4-5 years) but with this pattern reversing in older children (10-11 years). The improved performance in older boys on the aiming task is consistent with prior evidence of a male advantage for gross-motor aiming tasks, which begins to emerge during adolescence. A small but reliable sex difference was found in tracing skill, with girls showing a slightly higher level of performance than boys irrespective of age. There were no reliable sex differences between boys and girls on the tracking task. Overall, the findings suggest that prepubescent girls are more likely to have superior manual control abilities for performing novel tasks. However, these small population differences do not suggest that the sexes require different educational support whilst developing their manual skills.

  10. Resistance Training Reduces Force Tremor and Improves Manual Dexterity in Older Individuals With Essential Tremor.

    PubMed

    Kavanagh, Justin J; Wedderburn-Bisshop, Jacob; Keogh, Justin W L

    2016-01-01

    Although symptoms of Essential Tremor (ET) are typically controlled with medication, it is of interest to explore additional therapies to assist with functionality. The purpose of this study was to determine if a generalized upper limb resistance training (RT) program improves manual dexterity and reduces force tremor in older individuals with ET. Ten Essential Tremor and 9 controls were recruited into a dual group, pretest-posttest intervention study. Participants performed 6 weeks of upper-limb RT, and battery of manual dexterity and isometric force tremor assessments were performed before and after the RT to determine the benefits of the program. The six-week, high-load, RT program produced strength increases in each limb for the ET and healthy older group. These changes in strength aligned with improvements in manual dexterity and tremor-most notably for the ET group. The least affected limb and the most affected limb exhibited similar improvements in functional assessments of manual dexterity, whereas reductions in force tremor amplitude following the RT program were restricted to the most affected limb of the ET group. These findings suggest that generalized upper limb RT program has the potential to improve aspects of manual dexterity and reduce force tremor in older ET patients.

  11. Adopt-A-MACT Project: A Manual of Model Documents and Guidance to Aid Compliance and Enforcement of the Nutritional Yeast MACT (Maximum Achievable Control Technology)

    EPA Pesticide Factsheets

    This manual provides a compliance checklist, and overview of emissions limitations, how to do performance tests, and an overview of applicability of general provisions for the Nutritional Yeast NESHAP.

  12. Effective teaching of manual skills to physiotherapy students: a randomised clinical trial.

    PubMed

    Rossettini, Giacomo; Rondoni, Angie; Palese, Alvisa; Cecchetto, Simone; Vicentini, Marco; Bettale, Fernanda; Furri, Laura; Testa, Marco

    2017-08-01

    To date, despite the relevance of manual skills laboratories in physiotherapy education, evidence on the effectiveness of different teaching methods is limited. Peyton's four-step and the 'See one, do one' approaches were compared for their effectiveness in teaching manual skills. A cluster randomised controlled trial was performed among final-year, right-handed physiotherapy students, without prior experience in manual therapy or skills laboratories. The manual technique of C1-C2 passive right rotation was taught by different experienced physiotherapist using Peyton's four-step approach (intervention group) and the 'See one, do one' approach (control group). Participants, teachers and assessors were blinded to the aims of the study. Primary outcomes were quality of performance at the end of the skills laboratories, and after 1 week and 1 month. Secondary outcomes were time required to teach, time required to perform the procedure and student satisfaction. A total of 39 students were included in the study (21 in the intervention group and 18 in the control group). Their main characteristics were homogeneous at baseline. The intervention group showed better quality of performance in the short, medium and long terms (F 1,111  = 35.91, p < 0.001). Both groups demonstrated decreased quality of performance over time (F 2,111  = 12.91, p < 0.001). The intervention group reported significantly greater mean ± standard deviation satisfaction (4.31 ± 1.23) than the control group (4.03 ± 1.31) (p < 0.001). Although there was no significant difference between the two methods in the time required for teaching, the time required by the intervention group to perform the procedure was significantly lower immediately after the skills laboratories and over time (p < 0.001). Peyton's four-step approach is more effective than the 'See one, do one' approach in skills laboratories aimed at developing physiotherapy student competence in C1-C2 passive mobilisation. © 2017 John Wiley & Sons Ltd and The Association for the Study of Medical Education.

  13. Adaptive automation of human-machine system information-processing functions.

    PubMed

    Kaber, David B; Wright, Melanie C; Prinzel, Lawrence J; Clamann, Michael P

    2005-01-01

    The goal of this research was to describe the ability of human operators to interact with adaptive automation (AA) applied to various stages of complex systems information processing, defined in a model of human-automation interaction. Forty participants operated a simulation of an air traffic control task. Automated assistance was adaptively applied to information acquisition, information analysis, decision making, and action implementation aspects of the task based on operator workload states, which were measured using a secondary task. The differential effects of the forms of automation were determined and compared with a manual control condition. Results of two 20-min trials of AA or manual control revealed a significant effect of the type of automation on performance, particularly during manual control periods as part of the adaptive conditions. Humans appear to better adapt to AA applied to sensory and psychomotor information-processing functions (action implementation) than to AA applied to cognitive functions (information analysis and decision making), and AA is superior to completely manual control. Potential applications of this research include the design of automation to support air traffic controller information processing.

  14. To do it or to let an automatic tool do it? The priority of control over effort.

    PubMed

    Osiurak, François; Wagner, Clara; Djerbi, Sara; Navarro, Jordan

    2013-01-01

    The aim of the present study is to provide experimental data relevant to the issue of what leads humans to use automatic tools. Two answers can be offered. The first is that humans strive to minimize physical and/or cognitive effort (principle of least effort). The second is that humans tend to keep their perceived control over the environment (principle of more control). These two factors certainly play a role, but the question raised here is to what do people give priority in situations wherein both manual and automatic actions take the same time - minimizing effort or keeping perceived control? To answer that question, we built four experiments in which participants were confronted with a recurring choice between performing a task manually (physical effort) or in a semi-automatic way (cognitive effort) versus using an automatic tool that completes the task for them (no effort). In this latter condition, participants were required to follow the progression of the automatic tool step by step. Our results showed that participants favored the manual or semi-automatic condition over the automatic condition. However, when they were offered the opportunity to perform recreational tasks in parallel, the shift toward manual condition disappeared. The findings give support to the idea that people give priority to keeping control over minimizing effort.

  15. Effects of Attentional Focus and Age on Suprapostural Task Performance and Postural Control

    ERIC Educational Resources Information Center

    McNevin, Nancy; Weir, Patricia; Quinn, Tiffany

    2013-01-01

    Purpose: Suprapostural task performance (manual tracking) and postural control (sway and frequency) were examined as a function of attentional focus, age, and tracking difficulty. Given the performance benefits often found under external focus conditions, it was hypothesized that external focus instructions would promote superior tracking and…

  16. Aerobic Digestion. Student Manual. Biological Treatment Process Control.

    ERIC Educational Resources Information Center

    Klopping, Paul H.

    This manual contains the textual material for a single-lesson unit on aerobic sludge digestion. Topic areas addressed include: (1) theory of aerobic digestion; (2) system components; (3) performance factors; (4) indicators of stable operation; and (5) operational problems and their solutions. A list of objectives, glossary of key terms, and…

  17. Automation effects in a stereotypical multiloop manual control system. [for aircraft

    NASA Technical Reports Server (NTRS)

    Hess, R. A.; Mcnally, B. D.

    1984-01-01

    The increasing reliance of state-of-the art, high performance aircraft on high authority stability and command augmentation systems, in order to obtain satisfactory performance and handling qualities, has made critical the achievement of a better understanding of human capabilities, limitations, and preferences during interactions with complex dynamic systems that involve task allocation between man and machine. An analytical and experimental study has been undertaken to investigate human interaction with a simple, multiloop dynamic system in which human activity was systematically varied by changing the levels of automation. Task definition has led to a control loop structure which parallels that for any multiloop manual control system, and may therefore be considered a stereotype.

  18. Manual control of yaw motion with combined visual and vestibular cues

    NASA Technical Reports Server (NTRS)

    Zacharias, G. L.; Young, L. R.

    1977-01-01

    Measurements are made of manual control performance in the closed-loop task of nulling perceived self-rotation velocity about an earth-vertical axis. Self-velocity estimation was modelled as a function of the simultaneous presentation of vestibular and peripheral visual field motion cues. Based on measured low-frequency operator behavior in three visual field environments, a parallel channel linear model is proposed which has separate visual and vestibular pathways summing in a complementary manner. A correction to the frequency responses is provided by a separate measurement of manual control performance in an analogous visual pursuit nulling task. The resulting dual-input describing function for motion perception dependence on combined cue presentation supports the complementary model, in which vestibular cues dominate sensation at frequencies above 0.05 Hz. The describing function model is extended by the proposal of a non-linear cue conflict model, in which cue weighting depends on the level of agreement between visual and vestibular cues.

  19. The comparison of manual lymph drainage and ultrasound therapy on the leg swelling caused by wearing high heels.

    PubMed

    Lee, Dong-Yeop; Han, Ji-Su; Jang, Eun-Ji; Seo, Dong-Kwon; Hong, Ji-Heon; Lee, Sang-Sook; Lee, Dong-Geol; Yu Lee, Jae-Ho

    2014-01-01

    One of the major symptoms when women are wearing high heels for a long time is leg swelling. The purpose of this study was to compare the effect of manual lymph drainage with ultrasound therapy. The forty-five healthy women of twenties were participated in this study and divided randomly into three groups; manual lymph drainage group (n=15), ultrasound therapy group (n=15) and control group (n=15). Swelling was measured before wearing the high heels (10 cm-height), after one-hour of wearing the high heels, wearing the high heels of one-hour after the intervention of 15 minutes. Also swelling was calculated by using a tape measure, volumeter and body composition analyzer. Statistical analysis of the comparison between the three groups was performed by one-way ANOVA. Also comparison to the mean value in swelling according to the time was performed by repeated measure ANOVA. As the result of this study, a significant changes have emerged within each of manual lymph drainage, ultrasound therapy and control group (p< 0.05). However, there were no significant differences between each group (p> 0.05). But the mean value of manual lymph drainage group showed the tendency of fast recovering before causing swelling. Therefore, we consider that the clinical treatment of manual lymph drainage and ongoing studies will be made since manual lymph drainage is very effective in releasing the leg swelling caused by wearing high heels and standing for a long time at work.

  20. Research on an expert system for database operation of simulation-emulation math models. Volume 2, Phase 1: Results

    NASA Technical Reports Server (NTRS)

    Kawamura, K.; Beale, G. O.; Schaffer, J. D.; Hsieh, B. J.; Padalkar, S.; Rodriguez-Moscoso, J. J.

    1985-01-01

    A reference manual is provided for NESS, a simulation expert system. This manual gives user information regarding starting and operating NASA expert simulation system (NESS). This expert system provides an intelligent interface to a generic simulation program for spacecraft attitude control problems. A menu of the functions the system can perform is provided. Control repeated returns to this menu after executing each user request.

  1. Adaptive Training of Manual Control: 1. Comparison of Three Adaptive Variables and Two Logic Schemes.

    ERIC Educational Resources Information Center

    Norman, D. A.; And Others

    "Machine controlled adaptive training is a promising concept. In adaptive training the task presented to the trainee varies as a function of how well he performs. In machine controlled training, adaptive logic performs a function analogous to that performed by a skilled operator." This study looks at the ways in which gain-effective time…

  2. ZAG-Otolith: Modification of Otolith-Ocular Reflexes, Motion Perception and Manual Control during Variable Radius Centrifugation Following Space Flight

    NASA Technical Reports Server (NTRS)

    Wood, S. J.; Clarke, A. H.; Rupert, A. H.; Harm, D. L.; Clement, G. R.

    2009-01-01

    Two joint ESA-NASA studies are examining changes in otolith-ocular reflexes and motion perception following short duration space flights, and the operational implications of post-flight tilt-translation ambiguity for manual control performance. Vibrotactile feedback of tilt orientation is also being evaluated as a countermeasure to improve performance during a closed-loop nulling task. METHODS. Data is currently being collected on astronaut subjects during 3 preflight sessions and during the first 8 days after Shuttle landings. Variable radius centrifugation is utilized to elicit otolith reflexes in the lateral plane without concordant roll canal cues. Unilateral centrifugation (400 deg/s, 3.5 cm radius) stimulates one otolith positioned off-axis while the opposite side is centered over the axis of rotation. During this paradigm, roll-tilt perception is measured using a subjective visual vertical task and ocular counter-rolling is obtained using binocular video-oculography. During a second paradigm (216 deg/s, <20 cm radius), the effects of stimulus frequency (0.15 - 0.6 Hz) are examined on eye movements and motion perception. A closed-loop nulling task is also performed with and without vibrotactile display feedback of chair radial position. PRELIMINARY RESULTS. Data collection is currently ongoing. Results to date suggest there is a trend for perceived tilt and translation amplitudes to be increased at the low and medium frequencies on landing day compared to pre-flight. Manual control performance is improved with vibrotactile feedback. DISCUSSION. One result of this study will be to characterize the variability (gain, asymmetry) in both otolithocular responses and motion perception during variable radius centrifugation, and measure the time course of postflight recovery. This study will also address how adaptive changes in otolith-mediated reflexes correspond to one's ability to perform closed-loop nulling tasks following G-transitions, and whether manual control performance can be improved with vibrotactile feedback of orientation.

  3. Modification of Otolith-Ocular Reflexes, Motion Perception and Manual Control During Variable Radius Centrifugation Following Space Flight

    NASA Technical Reports Server (NTRS)

    Wood, Scott J.; Clarke, A. H.; Rupert, A. H.; Harm, D. L.; Clement, G. R.

    2009-01-01

    Two joint ESA-NASA studies are examining changes in otolith-ocular reflexes and motion perception following short duration space flights, and the operational implications of post-flight tilt-translation ambiguity for manual control performance. Vibrotactile feedback of tilt orientation is also being evaluated as a countermeasure to improve performance during a closed-loop nulling task. Data is currently being collected on astronaut subjects during 3 preflight sessions and during the first 8 days after Shuttle landings. Variable radius centrifugation is utilized to elicit otolith reflexes in the lateral plane without concordant roll canal cues. Unilateral centrifugation (400 deg/s, 3.5 cm radius) stimulates one otolith positioned off-axis while the opposite side is centered over the axis of rotation. During this paradigm, roll-tilt perception is measured using a subjective visual vertical task and ocular counter-rolling is obtained using binocular video-oculography. During a second paradigm (216 deg/s, less than 20 cm radius), the effects of stimulus frequency (0.15 - 0.6 Hz) are examined on eye movements and motion perception. A closed-loop nulling task is also performed with and without vibrotactile display feedback of chair radial position. Data collection is currently ongoing. Results to date suggest there is a trend for perceived tilt and translation amplitudes to be increased at the low and medium frequencies on landing day compared to pre-flight. Manual control performance is improved with vibrotactile feedback. One result of this study will be to characterize the variability (gain, asymmetry) in both otolith-ocular responses and motion perception during variable radius centrifugation, and measure the time course of post-flight recovery. This study will also address how adaptive changes in otolith-mediated reflexes correspond to one's ability to perform closed-loop nulling tasks following G-transitions, and whether manual control performance can be improved with vibrotactile feedback of orientation.

  4. Assessment of coarse and fine hand motor performance in asymptomatic subjects exposed to hand-arm vibration.

    PubMed

    Popević, Martin B; Janković, Srđan M; Borjanović, Srđan S; Jovičić, Slavica R; Tenjović, Lazar R; Milovanović, Aleksandar P S; Bulat, Petar

    2014-03-01

    A frequently encountered exposure profile for hand-arm vibration in contemporary occupational setting comprises workers with a long history of intermittent exposure but without detectable signs of hand-arm vibration syndrome (HAVS). Yet, most of the published studies deal with developed HAVS cases, rarely discussing the biological processes that may be involved in degradation of manual dexterity and grip strength when it can be most beneficial - during the asymptomatic stage. In the present paper, a group of 31 male asymptomatic vibration-exposed workers (according to the Stockholm Workshop Scale) were compared against 30 male controls. They were tested using dynamometry and dexterimetry (modelling coarse and fine manual performance respectively) and cold provocation was done to detect possible differences in manual performance drop on these tests. The results showed reduced manual dexterity but no significant degradation in hand grip strength in the exposed subjects. This suggests that intermittent exposure profile and small cumulative vibration dose could only lead to a measurable deficit in manual dexterity but not hand grip strength even at non-negligible A(8) levels and long term exposures.

  5. Manual therapy, exercise therapy, or both, in addition to usual care, for osteoarthritis of the hip or knee: a randomized controlled trial. 1: clinical effectiveness.

    PubMed

    Abbott, J H; Robertson, M C; Chapple, C; Pinto, D; Wright, A A; Leon de la Barra, S; Baxter, G D; Theis, J-C; Campbell, A J

    2013-04-01

    To evaluate the clinical effectiveness of manual physiotherapy and/or exercise physiotherapy in addition to usual care for patients with osteoarthritis (OA) of the hip or knee. In this 2 × 2 factorial randomized controlled trial, 206 adults (mean age 66 years) who met the American College of Rheumatology criteria for hip or knee OA were randomly allocated to receive manual physiotherapy (n = 54), multi-modal exercise physiotherapy (n = 51), combined exercise and manual physiotherapy (n = 50), or no trial physiotherapy (n = 51). The primary outcome was change in the Western Ontario and McMaster osteoarthritis index (WOMAC) after 1 year. Secondary outcomes included physical performance tests. Outcome assessors were blinded to group allocation. Of 206 participants recruited, 193 (93.2%) were retained at follow-up. Mean (SD) baseline WOMAC score was 100.8 (53.8) on a scale of 0-240. Intention to treat analysis showed adjusted reductions in WOMAC scores at 1 year compared with the usual care group of 28.5 (95% confidence interval (CI) 9.2-47.8) for usual care plus manual therapy, 16.4 (-3.2 to 35.9) for usual care plus exercise therapy, and 14.5 (-5.2 to 34.1) for usual care plus combined exercise therapy and manual therapy. There was an antagonistic interaction between exercise therapy and manual therapy (P = 0.027). Physical performance test outcomes favoured the exercise therapy group. Manual physiotherapy provided benefits over usual care, that were sustained to 1 year. Exercise physiotherapy also provided physical performance benefits over usual care. There was no added benefit from a combination of the two therapies. Australian New Zealand Clinical Trials Registry ACTRN12608000130369. Copyright © 2013 Osteoarthritis Research Society International. Published by Elsevier Ltd. All rights reserved.

  6. Training Manual for Elements of Interface Definition and Control

    NASA Technical Reports Server (NTRS)

    Lalli, Vincent R. (Editor); Kastner, Robert E. (Editor); Hartt, Henry N. (Editor)

    1997-01-01

    The primary thrust of this manual is to ensure that the format and information needed to control interfaces between equipment are clear and understandable. The emphasis is on controlling the engineering design of the interface and not on the functional performance requirements of the system or the internal workings of the interfacing equipment. Interface control should take place, with rare exception, at the interfacing elements and no further. There are two essential sections of the manual. Chapter 2, Principles of Interface Control, discusses how interfaces are defined. It describes different types of interfaces to be considered and recommends a format for the documentation necessary for adequate interface control. Chapter 3, The Process: Through the Design Phases, provides tailored guidance for interface definition and control. This manual can be used to improve planned or existing interface control processes during system design and development. It can also be used to refresh and update the corporate knowledge base. The information presented herein will reduce the amount of paper and data required in interface definition and control processes by as much as 50 percent and will shorten the time required to prepare an interface control document. It also highlights the essential technical parameters that ensure that flight subsystems will indeed fit together and function as intended after assembly and checkout.

  7. Automation effects in a multiloop manual control system

    NASA Technical Reports Server (NTRS)

    Hess, R. A.; Mcnally, B. D.

    1986-01-01

    An experimental and analytical study was undertaken to investigate human interaction with a simple multiloop manual control system in which the human's activity was systematically varied by changing the level of automation. The system simulated was the longitudinal dynamics of a hovering helicopter. The automation-systems-stabilized vehicle responses from attitude to velocity to position and also provided for display automation in the form of a flight director. The control-loop structure resulting from the task definition can be considered a simple stereotype of a hierarchical control system. The experimental study was complemented by an analytical modeling effort which utilized simple crossover models of the human operator. It was shown that such models can be extended to the description of multiloop tasks involving preview and precognitive human operator behavior. The existence of time optimal manual control behavior was established for these tasks and the role which internal models may play in establishing human-machine performance was discussed.

  8. Algorithm design, user interface, and optimization procedure for a fuzzy logic ramp metering algorithm : a training manual for freeway operations engineers

    DOT National Transportation Integrated Search

    2000-02-01

    This training manual describes the fuzzy logic ramp metering algorithm in detail, as implemented system-wide in the greater Seattle area. The method of defining the inputs to the controller and optimizing the performance of the algorithm is explained...

  9. Manual calf massage and passive ankle motion reduce the incidence of deep vein thromboembolism after total hip arthroplasty.

    PubMed

    Imai, Norio; Ito, Tomoyuki; Suda, Ken; Miyasaka, Dai; Endo, Naoto

    2017-07-01

    Venous thromboembolism is one of the general complications following total hip arthroplasty, wherein various preventive treatments have been recommended. Several studies reported that venous thromboembolism incidence after total hip arthroplasty was similar in patients who were administered prophylaxis with a conventional mechanical procedure alone, and those who were administered pharmacological anticoagulation therapy. Therefore, the optimum methods of prophylaxis are still controversial. The purpose of this study was to investigate whether manual calf massage and passive ankle motion could lower the risk for venous thromboembolism after total hip arthroplasty. We retrospectively reviewed the data of 126 consecutive patients undergoing elective primary unilateral total hip arthroplasty wherein manual calf massage and passive ankle motion were performed after the surgery at our hospitals between January and October 2014. The 138 patients of the control group underwent total hip arthroplasty using the same surgical approach and pre- and postoperative protocols without this mechanical prophylaxis between January and December 2013. This mechanical prophylaxis was performed simultaneously 30 times during approximately 10 s; these procedures were repeated thrice immediately after total hip arthroplasty. Duplex ultrasonography was performed to observe the veins of both legs in all the patients on postoperative day 7. The incidence of deep vein thrombosis was 6.52% and 0.79% in the control and manual calf massage and passive ankle motion groups, respectively. The odds ratio for the manual calf massage and passive ankle motion groups was 8.72. Performing this mechanical prophylaxis reduced the incidence of venous thromboembolism after total hip arthroplasty. This mechanical prophylaxis is not only simple and easy, but is also safe and inexpensive. We therefore recommend that manual calf massage and passive ankle motion be performed in patients who will undergo total hip arthroplasty, if deep vein thrombosis does not exist before the surgery. Copyright © 2017 The Japanese Orthopaedic Association. Published by Elsevier B.V. All rights reserved.

  10. Manual therapy in joint and nerve structures combined with exercises in the treatment of recurrent ankle sprains: A randomized, controlled trial.

    PubMed

    Plaza-Manzano, Gustavo; Vergara-Vila, Marta; Val-Otero, Sandra; Rivera-Prieto, Cristina; Pecos-Martin, Daniel; Gallego-Izquierdo, Tomás; Ferragut-Garcías, Alejandro; Romero-Franco, Natalia

    2016-12-01

    Recurrent ankle sprains often involve residual symptoms for which subjects often perform proprioceptive or/and strengthening exercises. However, the effectiveness of mobilization to influence important nerve structures due to its anatomical distribution like tibial and peroneal nerves is unclear. To analyze the effects of proprioceptive/strengthening exercises versus the same exercises and manual therapy including mobilizations to influence joint and nerve structures in the management of recurrent ankle sprains. A randomized single-blind controlled clinical trial. Fifty-six patients with recurrent ankle sprains and regular sports practice were randomly assigned to experimental or control group. The control group performed 4 weeks of proprioceptive/strengthening exercises; the experimental group performed 4 weeks of the same exercises combined with manual therapy (mobilizations to influence joint and nerve structures). Pain, self-reported functional ankle instability, pressure pain threshold (PPT), ankle muscle strength, and active range of motion (ROM) were evaluated in the ankle joint before, just after and one month after the interventions. The within-group differences revealed improvements in all of the variables in both groups throughout the time. Between-group differences revealed that the experimental group exhibited lower pain levels and self-reported functional ankle instability and higher PPT, ankle muscle strength and ROM values compared to the control group immediately after the interventions and one month later. A protocol involving proprioceptive and strengthening exercises and manual therapy (mobilizations to influence joint and nerve structures) resulted in greater improvements in pain, self-reported functional joint stability, strength and ROM compared to exercises alone. Copyright © 2016 Elsevier Ltd. All rights reserved.

  11. Manual Control Age and Sex Differences in 4 to 11 Year Old Children

    PubMed Central

    Flatters, Ian; Hill, Liam J. B.; Williams, Justin H. G.; Barber, Sally E.; Mon-Williams, Mark

    2014-01-01

    To what degree does being male or female influence the development of manual skills in pre-pubescent children? This question is important because of the emphasis placed on developing important new manual skills during this period of a child's education (e.g. writing, drawing, using computers). We investigated age and sex-differences in the ability of 422 children to control a handheld stylus. A task battery deployed using tablet PC technology presented interactive visual targets on a computer screen whilst simultaneously recording participant's objective kinematic responses, via their interactions with the on-screen stimuli using the handheld stylus. The battery required children use the stylus to: (i) make a series of aiming movements, (ii) trace a series of abstract shapes and (iii) track a moving object. The tasks were not familiar to the children, allowing measurement of a general ability that might be meaningfully labelled ‘manual control’, whilst minimising culturally determined differences in experience (as much as possible). A reliable interaction between sex and age was found on the aiming task, with girls' movement times being faster than boys in younger age groups (e.g. 4–5 years) but with this pattern reversing in older children (10–11 years). The improved performance in older boys on the aiming task is consistent with prior evidence of a male advantage for gross-motor aiming tasks, which begins to emerge during adolescence. A small but reliable sex difference was found in tracing skill, with girls showing a slightly higher level of performance than boys irrespective of age. There were no reliable sex differences between boys and girls on the tracking task. Overall, the findings suggest that prepubescent girls are more likely to have superior manual control abilities for performing novel tasks. However, these small population differences do not suggest that the sexes require different educational support whilst developing their manual skills. PMID:24523931

  12. Application of genetic algorithms to tuning fuzzy control systems

    NASA Technical Reports Server (NTRS)

    Espy, Todd; Vombrack, Endre; Aldridge, Jack

    1993-01-01

    Real number genetic algorithms (GA) were applied for tuning fuzzy membership functions of three controller applications. The first application is our 'Fuzzy Pong' demonstration, a controller that controls a very responsive system. The performance of the automatically tuned membership functions exceeded that of manually tuned membership functions both when the algorithm started with randomly generated functions and with the best manually-tuned functions. The second GA tunes input membership functions to achieve a specified control surface. The third application is a practical one, a motor controller for a printed circuit manufacturing system. The GA alters the positions and overlaps of the membership functions to accomplish the tuning. The applications, the real number GA approach, the fitness function and population parameters, and the performance improvements achieved are discussed. Directions for further research in tuning input and output membership functions and in tuning fuzzy rules are described.

  13. Experimental evaluation of the concept of supevisory manipulation

    NASA Technical Reports Server (NTRS)

    Brooks, T. L.; Sheridan, T. B.

    1982-01-01

    A computer-controlled teleoperator system which is based on task-referenced sensor-aided control has been developed to study supervisory manipulation. This system, called SUPERMAN, is capable of performing complicated tasks in real-time by utilizing the operator for high-level functions related to the unpredictable portions of a task, while the subordinate machine performs the more well-defined subtasks under human supervison. To determine whether supervisory control schemes such as these offer any advantage over manual control under real-time conditions, a number of experiments involving both simple and complicated tasks were performed. Six representative tasks were chosen for the study: (1) obtaining a tool from a rack, (2) returning the tool to the rack, (3) removing a nut, (4) placing samples in a storage bin, (5) opening and closing a valve, and (6) digging with a shovel. The experiments were performed under simulated conditions using four forms of manual control (i.e., switch rate, joystick rate, master-slave position control, and master-slave with force feedback), as well as supervisory control. Through these experiments the effectiveness and quality of control were evaluated on the basis of the time required to complete each portion of the task and the type and number of errors which occurred.

  14. Modeling of Depth Cue Integration in Manual Control Tasks

    NASA Technical Reports Server (NTRS)

    Sweet, Barbara T.; Kaiser, Mary K.; Davis, Wendy

    2003-01-01

    Psychophysical research has demonstrated that human observers utilize a variety of visual cues to form a perception of three-dimensional depth. However, most of these studies have utilized a passive judgement paradigm, and failed to consider depth-cue integration as a dynamic and task-specific process. In the current study, we developed and experimentally validated a model of manual control of depth that examines how two potential cues (stereo disparity and relative size) are utilized in both first- and second-order active depth control tasks. We found that stereo disparity plays the dominate role for determining depth position, while relative size dominates perception of depth velocity. Stereo disparity also plays a reduced role when made less salient (i.e., when viewing distance is increased). Manual control models predict that position information is sufficient for first-order control tasks, while velocity information is required to perform a second-order control task. Thus, the rules for depth-cue integration in active control tasks are dependent on both task demands and cue quality.

  15. Equipment Management Manual

    NASA Technical Reports Server (NTRS)

    1992-01-01

    The NASA Equipment Management Manual (NHB 4200.1) is issued pursuant to Section 203(c)(1) of the National Aeronautics and Space Act of 1958, as amended (42 USC 2473), and sets forth policy, uniform performance standards, and procedural guidance to NASA personnel for the acquisition, management, and use of NASA-owned equipment. This revision is effective upon receipt. This is a controlled manual, issued in loose-leaf form, and revised through page changes. Additional copies for internal use may be obtained through normal distribution.

  16. Impact of pay for performance on quality of chronic disease management by social class group in England.

    PubMed

    Crawley, Danielle; Ng, Anthea; Mainous, Arch G; Majeed, Azeem; Millett, Christopher

    2009-03-01

    To examine associations between social class and achievement of selected national audit targets for coronary heart disease (CHD), diabetes and hypertension in England before and after the introduction of a major pay for performance programme in 2004. Secondary analysis of 2003 and 2006 national survey data for respondents with CHD and diabetes and hypertension. England. Achievement of national audit targets for blood pressure, blood glucose and cholesterol control. There were no significant differences in achievement of blood pressure targets in individuals from manual and non-manual occupational groups with diabetes (2003: 65.9% v 60.3%, 2006: 67.6% v 69.7%) or hypertension (2003: 66.2% v 66.2%, 2006: 72.8% v 71.9%) before or after the introduction of pay for performance. Achievement of the cholesterol target was also similar in individuals from manual and non-manual groups with diabetes (2003: 52.5% v 46.6%, 2006: 68.7% v 70.5%) or CHD (2003: 54.3% v 53.3%, 2006: 68.6% v 71.3%). Differences in achievement of the blood pressure target in CHD [75.8% v 84.5%; AOR 0.44 (0.21-0.90)] were evident between manual and non-manual occupational groups after the introduction of pay for performance. The quality of chronic disease management in England was broadly equitable between socioeconomic groups before this major pay for performance programme and remained so after its introduction.

  17. A dissociation of objective and subjective workload measures in assessing the impact of speech controls in advanced helicopters

    NASA Technical Reports Server (NTRS)

    Vidulich, Michael A.; Bortolussi, Michael R.

    1988-01-01

    Among the new technologies that are expected to aid helicopter designers are speech controls. Proponents suggest that speech controls could reduce the potential for manual control overloads and improve time-sharing performance in environments that have heavy demands for manual control. This was tested in a simulation of an advanced single-pilot, scout/attack helicopter. Objective performance indicated that the speech controls were effective in decreasing the interference of discrete responses during moments of heavy flight control activity. However, subjective ratings indicated that the use of speech controls required extra effort to speak precisely and to attend to feedback. Although the operational reliability of speech controls must be improved, the present results indicate that reliable speech controls could enhance the time-sharing efficiency of helicopter pilots. Furthermore, the results demonstrated the importance of using multiple assessment techniques to completely assess a task. Neither the objective nor the subjective measures alone provided complete information. It was the contrast between the measures that was most informative.

  18. TA-55 change control manual

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Blum, T.W.; Selvage, R.D.; Courtney, K.H.

    This manual is the guide for initiating change at the Plutonium Facility, which handles the processing of plutonium as well as research on plutonium metallurgy. It describes the change and work control processes employed at TA-55 to ensure that all proposed changes are properly identified, reviewed, approved, implemented, tested, and documented so that operations are maintained within the approved safety envelope. All Laboratory groups, their contractors, and subcontractors doing work at TA-55 follow requirements set forth herein. This manual applies to all new and modified processes and experiments inside the TA-55 Plutonium Facility; general plant project (GPP) and line itemmore » funded construction projects at TA-55; temporary and permanent changes that directly or indirectly affect structures, systems, or components (SSCs) as described in the safety analysis, including Facility Control System (FCS) software; and major modifications to procedures. This manual does not apply to maintenance performed on process equipment or facility SSCs or the replacement of SSCs or equipment with documented approved equivalents.« less

  19. Manual flying of curved precision approaches to landing with electromechanical instrumentation. A piloted simulation study

    NASA Technical Reports Server (NTRS)

    Knox, Charles E.

    1993-01-01

    A piloted simulation study was conducted to examine the requirements for using electromechanical flight instrumentation to provide situation information and flight guidance for manually controlled flight along curved precision approach paths to a landing. Six pilots were used as test subjects. The data from these tests indicated that flight director guidance is required for the manually controlled flight of a jet transport airplane on curved approach paths. Acceptable path tracking performance was attained with each of the three situation information algorithms tested. Approach paths with both multiple sequential turns and short final path segments were evaluated. Pilot comments indicated that all the approach paths tested could be used in normal airline operations.

  20. The effect of standing desks on manual control in children and young adults.

    PubMed

    Britten, L; Shire, K; Coats, R O; Astill, S L

    2016-07-01

    The aim of the present study was to establish if and how the additional postural constraint of standing affects accuracy and precision of goal directed naturalistic actions. Forty participants, comprising 20 young adults aged 20-23 years and 20 children aged 9-10 years completed 3 manual dexterity tasks on a tablet laptop with a handheld stylus during two separate conditions (1) while standing and (2) while seated. The order of conditions was counterbalanced across both groups of participants. The tasks were (1) a tracking task, where the stylus tracked a dot in a figure of 8 at 3 speeds, (2) an aiming task where the stylus moved from dot to dot with individual movements creating the outline of a pentagram and (3) a tracing task, where participants had to move the stylus along a static pathway or maze. Root mean squared error (RMSE), movement time and path accuracy, respectively, were used to quantify the effect that postural condition had on manual control. Overall adults were quicker and more accurate than children when performing all 3 tasks, and where the task speed was manipulated accuracy was better at slower speeds for all participants. Surprisingly, children performed these tasks more quickly and more accurately when standing compared to when sitting. In conclusion, standing at a desk while performing goal directed tasks did not detrimentally affect children's manual control, and moreover offered a benefit. Copyright © 2016 Elsevier B.V. All rights reserved.

  1. A hand and a field effect in on-line motor control in unilateral optic ataxia.

    PubMed

    Blangero, Annabelle; Gaveau, Valérie; Luauté, Jacques; Rode, Gilles; Salemme, Romeo; Guinard, Marine; Boisson, Dominique; Rossetti, Yves; Pisella, Laure

    2008-05-01

    Patients with bilateral optic ataxia fail to show rapid perturbation-induced corrections during manual aiming movements. Based on this, it has been proposed that this pathology results from a disruption of processes of on-line motor control in the posterior parietal cortex (PPC). Here, we show that on-line motor control performance in a patient with unilateral optic ataxia is similar to that of pointing towards stationary targets in peripheral vision, showing the same combination of hand and field effects. We also show that in the patient, manual correction towards his ataxic field was possible only when a preceding saccade (100msec earlier) rapidly provides foveal information about the new target location. In control subjects, manual correction was often, but not necessarily preceded by a saccade. These results allow us to put forward a model of visuo-manual transformation, which involves updating of the reach plan based on the target-eye error, and rely upon two dissociated spatial representations (of the hand and of the target, respectively) within the PPC.

  2. Higher order balance control: Distinct effects between cognitive task and manual steadiness constraint on automatic postural responses.

    PubMed

    Coelho, Daniel Boari; Bourlinova, Catarina; Teixeira, Luis Augusto

    2016-12-01

    In the present experiment, we aimed to evaluate the interactive effect of performing a cognitive task simultaneously with a manual task requiring either high or low steadiness on APRs. Young volunteers performed the task of recovering upright balance following a mechanical perturbation provoked by unanticipatedly releasing a load pulling the participant's body backwards. The postural task was performed while holding a cylinder steadily on a tray. One group performed that task under high (cylinder' round side down) and another one under low (cylinder' flat side down) manual steadiness constraint. Those tasks were evaluated in the conditions of performing concurrently a cognitive numeric subtraction task and under no cognitive task. Analysis showed that performance of the cognitive task led to increased body and tray displacement, associated with higher displacement at the hip and upper trunk, and lower magnitude of activation of the GM muscle in response to the perturbation. Conversely, high manual steadiness constraint led to reduced tray velocity in association with lower values of trunk displacement, and decreased rotation amplitude at the ankle and hip joints. We found no interactions between the effects of the cognitive and manual tasks on APRs, suggesting that they were processed in parallel in the generation of responses for balance recovery. Modulation of postural responses from the manual and cognitive tasks indicates participation of higher order neural structures in the generation of APRs, with postural responses being affected by multiple mental processes occurring in parallel. Copyright © 2016 Elsevier B.V. All rights reserved.

  3. The Effects of Divided Attention on Speech Motor, Verbal Fluency, and Manual Task Performance

    ERIC Educational Resources Information Center

    Dromey, Christopher; Shim, Erin

    2008-01-01

    Purpose: The goal of this study was to evaluate aspects of the "functional distance hypothesis," which predicts that tasks regulated by brain networks in closer anatomic proximity will interfere more with each other than tasks controlled by spatially distant regions. Speech, verbal fluency, and manual motor tasks were examined to ascertain whether…

  4. Effectiveness of Plaque Control with Novel Pediatric Oral Hygiene Need Station (Modified Oral Irrigation Device) as Compared with Manual Brushing and Flossing: Randomized Controlled Pilot Trial.

    PubMed

    Murthy, Prashanth Sadashiva; Shaik, Naseemoon; Deshmukh, Seema; Girish, M S

    2018-01-01

    Establishing good hygiene habits are valuable for present and future oral health. Below 6 years, tooth brushing should be performed by parents, as increasing dexterity and cognition may permit supervised brushing until the child is capable of independent brushing. The aim of the present study was to evaluate the effectiveness of modified oral irrigation device in children in terms of plaque control and to compare the effectiveness of plaque control with manual brushing with the modified oral irrigation device in children. A randomized clinical trial was performed on 12 subjects who were allocated to the two study groups. After obtaining the consent, the control group was instructed tooth brushing with regular pediatric commercially available toothbrush and the intervention group with modified oral irrigation device. Plaque scores in both groups were assessed pre- and post-brushing using modified navy plaque index. The data were subjected to Descriptive statistics and Paired t -test using SPSS version 22. Intragroup comparison of mean difference of plaque score in control group and intervention group pre- and post-brushing was statistically significant. Intergroup comparison of manual brushing group with modified oral irrigation group shows P < 0.05 was statistically significant. Within the limitation of the present study, it has been found novel pediatric oral hygiene need Station is more effective than manual brushing since it combined the effect of brushing, flossing (water floss), and rinsing in children simultaneously and at the same time did not demand any special motor skill.

  5. Thermal/structural Tailoring of Engine Blades (T/STAEBL) User's Manual

    NASA Technical Reports Server (NTRS)

    Brown, K. W.; Clevenger, W. B.; Arel, J. D.

    1994-01-01

    The Thermal/Structural Tailoring of Engine Blades (T/STAEBL) system is a family of computer programs executed by a control program. The T/STAEBL system performs design optimizations of cooled, hollow turbine blades and vanes. This manual contains an overview of the system, fundamentals of the data block structure, and detailed descriptions of the inputs required by the optimizer. Additionally, the thermal analysis input requirements are described as well as the inputs required to perform a finite element blade vibrations analysis.

  6. Evaluation of pavement marking performance.

    DOT National Transportation Integrated Search

    2008-06-01

    The objective of the investigation was to evaluate the useful life of pavement markings. The Manual on Uniform Traffic Control Devices (MUTCD) provides general guidelines for the application and installation of pavement markings. However, performance...

  7. Training children aged 5-10 years in manual compliance control to improve drawing and handwriting.

    PubMed

    Bingham, Geoffrey P; Snapp-Childs, Winona

    2018-04-12

    A large proportion of school-aged children exhibit poor drawing and handwriting. This prevalence limits the availability of therapy. We developed an automated method for training improved manual compliance control and relatedly, prospective control of a stylus. The approach included a difficult training task, while providing parametrically modifiable support that enables the children to perform successfully while developing good compliance control. The task was to use a stylus to push a bead along a 3D wire path. Support was provided by making the wire magnetically attractive to the stylus. Support was progressively reduced as 3D tracing performance improved. We report studies that (1) compared performance of Typically Developing (TD) children and children with Developmental Coordination Disorder (DCD), (2) tested training with active versus passive movement, (3) tested progressively reduced versus constant or no support during training, (4) tested children of different ages, (5) tested the transfer of training to a drawing task, (6) tested the specificity of training in respect to the size, shape and dimensionality of figures, and (7) investigated the relevance of the training task to the Beery VMI, an inventory used to diagnose DCD. The findings were as follows. (1) Pre-training performance of TD and DCD children was the same and good with high support but distinct and poor with low support. Support yielded good self-efficacy that motivated training. Post training performance with no support was improved and the same for TD and DCD children. (2) Actively controlled movements were required for improved performance. (3) Progressively reduced support was required for good performance during and after training. (4) Age differences in performance during pre-training were eliminated post-training. (5) Improvements transferred to drawing. (6) There was no evidence of specificity of training in transfer. (7) Disparate Beery scores were reflected in pre-training but not post-training performance. We conclude that the method improves manual compliance control, and more generally, prospective control of movements used in drawing performance. Copyright © 2018. Published by Elsevier B.V.

  8. Space Flight and Manual Control: Implications for Sensorimotor Function on Future Missions

    NASA Technical Reports Server (NTRS)

    Reschke, Millard F.; Kornilova, Ludmila; Tomilovskaya, Elena; Parker, Donald E.; Leigh, R. John; Kozlovskaya, Inessa

    2009-01-01

    Control of vehicles, and other complex mechanical motion systems, is a high-level integrative function of the central nervous system (CNS) that requires good visual acuity, eye-hand coordination, spatial (and, in some cases, geographic) orientation perception, and cognitive function. Existing evidence from space flight research (Paloski et.al., 2008, Clement and Reschke 2008, Reschke et al., 2007) demonstrates that the function of each of these systems is altered by removing (and subsequently by reintroducing) a gravitational field that can be sensed by vestibular, proprioceptive, and haptic receptors and used by the CNS for spatial orientation, navigation, and coordination of movements. Furthermore, much of the operational performance data collected as a function of space flight has not been available for independent analysis, and those data that have been reviewed are equivocal owing to uncontrolled environmental and/or engineering factors. Thus, our current understanding, when it comes to manual control, is limited primarily to a review of those situations where manual control has been a factor. One of the simplest approaches to the manual control problem is to review shuttle landing data. See the Figure below for those landing for which we have Shuttle velocities over the runway threshold.

  9. The effect of manual therapy and exercise in patients with chronic low back pain: Double blind randomized controlled trial.

    PubMed

    Ulger, Ozlem; Demirel, Aynur; Oz, Müzeyyen; Tamer, Seval

    2017-11-06

    To determine the effects of spinal stabilization exercises (SSE) and manual therapy methods on pain, function and quality of life (QoL) levels in individuals with chronic low back pain (CLBP). A total of one-hundred thirteen patients diagnosed as CLBP were enrolled to the study. The patients allocated into Spinal Stabilization group (SG) and manual therapy group (MG), randomly. While SSE performed in SG, soft tissue mobilizations, muscle-energy techniques, joint mobilizations and manipulations were performed in MG. While the severity of pain was assessed with Visual Analog Scale (VAS), Oswestry Disability Index (ODI) and Short Form 36 (SF-36) assessments were performed to evaluate the functional status and QoL, respectively. All assessments were repeated before and after the treatment. Intragroup analyses both treatments were effective in terms of sub parameters of pain, function and life quality (p< 0.05). Inter group analyses, there was more reduction in pain and improvement in functional status in favor of MG (p< 0.05). This study showed that SSE and manual therapy methods have the same effects on QoL, while the manual treatment is more effective on the pain and functional parameters in particular.

  10. The Effect of Visual Information on the Manual Approach and Landing

    NASA Technical Reports Server (NTRS)

    Wewerinke, P. H.

    1982-01-01

    The effect of visual information in combination with basic display information on the approach performance. A pre-experimental model analysis was performed in terms of the optimal control model. The resulting aircraft approach performance predictions were compared with the results of a moving base simulator program. The results illustrate that the model provides a meaningful description of the visual (scene) perception process involved in the complex (multi-variable, time varying) manual approach task with a useful predictive capability. The theoretical framework was shown to allow a straight-forward investigation of the complex interaction of a variety of task variables.

  11. Comparison of double intravenous vasopressor automated system using nexfin versus manual vasopressor bolus administration for maintenance of haemodynamic stability during spinal anaesthesia for caesarean delivery: A randomised double-blind controlled trial.

    PubMed

    Sng, Ban Leong; Du, Wei; Lee, Man Xin; Ithnin, Farida; Mathur, Deepak; Leong, Wan Ling; Sultana, Rehena; Han, Nian-Lin R; Sia, Alex Tiong Heng

    2018-05-01

    Hypotension is a common side effect of spinal anaesthesia during caesarean delivery and is associated with maternal and foetal adverse effects. We developed an updated double intravenous vasopressor automated (DIVA) system that administers phenylephrine or ephedrine based on continuous noninvasive haemodynamic monitoring using the Nexfin device. The aim of our present study is to compare the performance and reliability of the DIVA system against Manual Vasopressor Bolus administration. A randomised, double-blind controlled trial. Single-centre, KK Women's and Children's Hospital, Singapore. Two hundred and thirty-six healthy women undergoing elective caesarean delivery under spinal anaesthesia. The primary outcome was the incidence of maternal hypotension. The secondary outcome measures were reactive hypertension, total vasopressor requirement and maternal and neonatal outcomes. The DIVA group had a significantly lower incidence of maternal hypotension, with 39.3% (46 of 117) patients having any SBP reading less than 80% of baseline compared with 57.5% (65 of 113) in the manual vasopressor bolus group (P = 0.008). The DIVA group also had fewer hypotensive episodes than the manual vasopressor bolus group (4.67 versus 7.77%; P < 0.0001). There was no difference in the incidence of reactive hypertension or the total vasopressor requirement. The DIVA group had less wobble in system performance. Maternal and neonatal outcomes were similar. The DIVA system achieved better control of maternal blood pressure after spinal anaesthesia than manual vasopressor bolus administration. Clinicaltrials.gov identifier: NCT02277730.

  12. Manual for guided home exercises for osteoarthritis of the knee.

    PubMed

    Carvalho, Nilza Aparecida de Almeida; Bittar, Simoni Teixeira; Pinto, Flávia Ribeiro de Souza; Ferreira, Mônica; Sitta, Robson Roberto

    2010-06-01

    Physiotherapy is one of the most important components of therapy for osteoarthritis of the knee. The objective of this prospective case series was to assess the efficiency of a guidance manual for patients with osteoarthritis of the knee in relation to pain, range of movement , muscle strength and function, active goniometry, manual strength test and function. Thirty-eight adults with osteoarthritis of the knee (>or= 45 years old) who were referred to the physiotherapy service at the university hospital (Santa Casa de Misericórdia de São Paulo) were studied. Patients received guidance for the practice of specific physical exercises and a manual with instructions on how to perform the exercises at home. They were evaluated for pain, range of movement, muscle strength and function. These evaluations were performed before they received the manual and three months later. Patients were seen monthly regarding improvements in their exercising abilities. The program was effective for improving muscle strength, controlling pain, maintaining range of movement of the knee joint, and reducing functional incapacity. A review of the literature showed that there are numerous clinical benefits to the regular practice of physical therapy exercises by patients with osteoarthritis of the knee(s) in a program with appropriate guidance. This study shows that this guidance can be attained at home with the use of a proper manual. Even when performed at home without constant supervision, the use of the printed manual for orientation makes the exercises for osteoarthritis of the knee beneficial.

  13. Performance test of nutrient control equipment for hydroponic plants

    NASA Astrophysics Data System (ADS)

    Rahman, Nurhaidar; Kuala, S. I.; Tribowo, R. I.; Anggara, C. E. W.; Susanti, N. D.

    2017-11-01

    Automatic control equipment has been made for the nutrient content in irrigation water for hydroponic plants. Automatic control equipment with CCT53200E conductivity controller to nutrient content in irrigation water for hydroponic plants, can be used to control the amount of TDS of nutrient solution in the range of TDS numbers that can be set according to the range of TDS requirements for the growth of hydroponically cultivated crops. This equipment can minimize the work time of hydroponic crop cultivators. The equipment measurement range is set between 1260 ppm up to 1610 ppm for spinach plants. Caisim plants were included in this experiment along with spinach plants with a spinach plants TDS range. The average of TDS device is 1450 ppm, while manual (conventional) is 1610 ppm. Nutrient solution in TDS controller has pH 5,5 and temperature 29,2 °C, while manual is pH 5,6 and temperature 31,3 °C. Manually treatment to hydroponic plant crop, yields in an average of 39.6 grams/plant, greater than the yield of spinach plants with TDS control equipment, which is in an average of 24.6 grams / plant. The yield of caisim plants by manual treatment is in an average of 32.3 grams/crop, less than caisim crop yields with TDS control equipment, which is in an average of 49.4 grams/plant.

  14. Calculations of financial incentives for providers in a pay-for-performance program: Manual review versus data from structured fields in electronic health records

    PubMed Central

    Urech, Tracy H.; Woodard, LeChauncy D.; Virani, Salim S.; Dudley, R. Adams; Lutschg, Meghan Z.; Petersen, Laura A.

    2015-01-01

    Background Hospital report cards and financial incentives linked to performance require clinical data that are reliable, appropriate, timely, and cost-effective to process. Pay-for-performance plans are transitioning to automated electronic health record (EHR) data as an efficient method to generate data needed for these programs. Objective To determine how well data from automated processing of structured EHR fields (AP-EHR) reflect data from manual chart review and the impact of these data on performance rewards. Research Design Cross-sectional analysis of performance measures used in a cluster randomized trial assessing the impact of financial incentives on guideline-recommended care for hypertension. Subjects A total of 2,840 patients with hypertension assigned to participating physicians at 12 Veterans Affairs hospital-based outpatient clinics. Fifty-two physicians and 33 primary care personnel received incentive payments. Measures Overall, positive and negative agreement indices and Cohen's kappa were calculated for assessments of guideline-recommended antihypertensive medication use, blood pressure (BP) control, and appropriate response to uncontrolled BP. Pearson's correlation coefficient was used to assess how similar participants’ calculated earnings were between the data sources. Results By manual chart review data, 72.3% of patients were considered to have received guideline-recommended antihypertensive medications compared to 65.0% by AP-EHR review (k=0.51). Manual review indicated 69.5% of patients had controlled BP compared to 66.8% by AP-EHR review (k=0.87). Compared to 52.2% of patients per the manual review, 39.8% received an appropriate response by AP-EHR review (k=0.28). Participants’ incentive payments calculated using the two methods were highly correlated (r≥0.98). Using the AP-EHR data to calculate earnings, participants’ payment changes ranged from a decrease of $91.00 (−30.3%) to an increase of $18.20 (+7.4%) for medication use (IQR, −14.4% to 0%) and a decrease of $100.10 (−31.4%) to an increase of $36.40 (+15.4%) for BP control or appropriate response to uncontrolled BP (IQR, −11.9% to −6.1%). Conclusions Pay-for-performance plans that use only EHR data should carefully consider the measures and the structure of the EHR before data collection and financial incentive disbursement. For this study, we feel that a 10% difference in the total amount of incentive earnings disbursed based on AP-EHR data compared to manual review is acceptable given the time and resources required to abstract data from medical records. PMID:26340661

  15. Experimental analysis of robot-assisted needle insertion into porcine liver.

    PubMed

    Wang, Wendong; Shi, Yikai; Goldenberg, Andrew A; Yuan, Xiaoqing; Zhang, Peng; He, Lijing; Zou, Yingjie

    2015-01-01

    How to improve placement accuracy of needle insertion into liver tissue is of paramount interest to physicians. A robot-assisted system was developed to experimentally demonstrate its advantages in needle insertion surgeries. Experiments of needle insertion into porcine liver tissue were performed with conic tip needle (diameter 8 mm) and bevel tip needle (diameter 1.5 mm) in this study. Manual operation was designed to compare the performance of the presented robot-assisted system. The real-time force curves show outstanding advantages of robot-assisted operation in improving the controllability and stability of needle insertion process by comparing manual operation. The statistics of maximum force and average force further demonstrates robot-assisted operation causes less oscillation. The difference of liver deformation created by manual operation and robot-assisted operation is very low, 1 mm for average deformation and 2 mm for maximum deformation. To conclude, the presented robot-assisted system can improve placement accuracy of needle by stably control insertion process.

  16. NCC simulation model. Phase 2: Simulating the operations of the Network Control Center and NCC message manual

    NASA Technical Reports Server (NTRS)

    Benjamin, Norman M.; Gill, Tepper; Charles, Mary

    1994-01-01

    The network control center (NCC) provides scheduling, monitoring, and control of services to the NASA space network. The space network provides tracking and data acquisition services to many low-earth orbiting spacecraft. This report describes the second phase in the development of simulation models for the FCC. Phase one concentrated on the computer systems and interconnecting network.Phase two focuses on the implementation of the network message dialogs and the resources controlled by the NCC. Performance measures were developed along with selected indicators of the NCC's operational effectiveness.The NCC performance indicators were defined in terms of the following: (1) transfer rate, (2) network delay, (3) channel establishment time, (4) line turn around time, (5) availability, (6) reliability, (7) accuracy, (8) maintainability, and (9) security. An NCC internal and external message manual is appended to this report.

  17. Effectiveness of Plaque Control with Novel Pediatric Oral Hygiene Need Station (Modified Oral Irrigation Device) as Compared with Manual Brushing and Flossing: Randomized Controlled Pilot Trial

    PubMed Central

    Murthy, Prashanth Sadashiva; Shaik, Naseemoon; Deshmukh, Seema; Girish, M. S.

    2018-01-01

    Background: Establishing good hygiene habits are valuable for present and future oral health. Below 6 years, tooth brushing should be performed by parents, as increasing dexterity and cognition may permit supervised brushing until the child is capable of independent brushing. Aim and Objectives: The aim of the present study was to evaluate the effectiveness of modified oral irrigation device in children in terms of plaque control and to compare the effectiveness of plaque control with manual brushing with the modified oral irrigation device in children. Materials and Methods: A randomized clinical trial was performed on 12 subjects who were allocated to the two study groups. After obtaining the consent, the control group was instructed tooth brushing with regular pediatric commercially available toothbrush and the intervention group with modified oral irrigation device. Plaque scores in both groups were assessed pre- and post-brushing using modified navy plaque index. Results: The data were subjected to Descriptive statistics and Paired t-test using SPSS version 22. Intragroup comparison of mean difference of plaque score in control group and intervention group pre- and post-brushing was statistically significant. Intergroup comparison of manual brushing group with modified oral irrigation group shows P < 0.05 was statistically significant. Conclusion: Within the limitation of the present study, it has been found novel pediatric oral hygiene need Station is more effective than manual brushing since it combined the effect of brushing, flossing (water floss), and rinsing in children simultaneously and at the same time did not demand any special motor skill. PMID:29875555

  18. Implementation of remote video auditing with feedback and compliance for manual-cleaning protocols of endoscopic retrograde cholangiopancreatography endoscopes.

    PubMed

    Armellino, Donna; Cifu, Kelly; Wallace, Maureen; Johnson, Sherly; DiCapua, John; Dowling, Oonagh; Jacobs, Mitchel; Browning, Susan

    2018-05-01

    A pilot initiative to assess the use of remote video auditing in monitoring compliance with manual-cleaning protocols for endoscopic retrograde cholangiopancreatography (ERCP) endoscopes was performed. Compliance with manual-cleaning steps following the initiation of feedback was measured. A video feed of the ERCP reprocessing room was provided to remote auditors who scored items of an ERCP endoscope manual-cleaning checklist. Compliance feedback was provided in the form of reports and reeducation. Outcomes were reported as checklist compliance. The use of remote video auditing to document manual processing is a feasible approach and feedback and reeducation increased manual-cleaning compliance from 53.1% (95% confidence interval, 34.7-71.6) to 98.9% (95.0% confidence interval, 98.1-99.6). Copyright © 2018 Association for Professionals in Infection Control and Epidemiology, Inc. Published by Elsevier Inc. All rights reserved.

  19. Assessment of Alternative Interfaces for Manual Commanding of Spacecraft Systems: Compatibility with Flexible Allocation Policies

    NASA Technical Reports Server (NTRS)

    Billman, Dorrit Owen; Schreckenghost, Debra; Miri, Pardis

    2014-01-01

    Astronauts will be responsible for executing a much larger body of procedures as human exploration moves further from Earth and Mission Control. Efficient, reliable methods for executing these procedures, including manual, automated, and mixed execution will be important. Our interface integrates step-by-step instruction with the means for execution. The research reported here compared manual execution using the new system to a system analogous to the manual-only system currently in use on the International Space Station, to assess whether user performance in manual operations would be as good or better with the new than with the legacy system. The system used also allows flexible automated execution. The system and our data lay the foundation for integrating automated execution into the flow of procedures designed for humans. In our formative study, we found speed and accuracy of manual procedure execution was better using the new, integrated interface over the legacy design.

  20. Kaleri works with the TORU teleoperated control system in the SM during Expedition 8

    NASA Image and Video Library

    2004-01-30

    ISS008-E-14073 (30 January 2004) --- Cosmonaut Alexander Y. Kaleri, Expedition 8 flight engineer, practices docking procedures with the manual TORU rendezvous system in the Zvezda Service Module on the International Space Station (ISS) in preparation for the docking of the Progress 13 on January 31. With the manual TORU mode, Kaleri can perform necessary guidance functions from Zvezda via two hand controllers in the event of a failure of the “Kurs” automated rendezvous and docking (AR&D) of the Progress. Kaleri represents Rosaviakosmos.

  1. Kaleri works with the TORU teleoperated control system in the SM during Expedition 8

    NASA Image and Video Library

    2004-01-30

    ISS008-E-14076 (30 January 2004) --- Cosmonaut Alexander Y. Kaleri, Expedition 8 flight engineer, practices docking procedures with the manual TORU rendezvous system in the Zvezda Service Module on the International Space Station (ISS) in preparation for the docking of the Progress 13 on January 31. With the manual TORU mode, Kaleri can perform necessary guidance functions from Zvezda via two hand controllers in the event of a failure of the “Kurs” automated rendezvous and docking (AR&D) of the Progress. Kaleri represents Rosaviakosmos.

  2. Kaleri works with the TORU teleoperated control system in the SM during Expedition 8

    NASA Image and Video Library

    2004-01-30

    ISS008-E-14067 (30 January 2004) --- Cosmonaut Alexander Y. Kaleri, Expedition 8 flight engineer, practices docking procedures with the manual TORU rendezvous system in the Zvezda Service Module on the International Space Station (ISS) in preparation for the docking of the Progress 13 on January 31. With the manual TORU mode, Kaleri can perform necessary guidance functions from Zvezda via two hand controllers in the event of a failure of the “Kurs” automated rendezvous and docking (AR&D) of the Progress. Kaleri represents Rosaviakosmos.

  3. Preparation of forefinger's sequence on keyboard orients ocular fixations on computer screen.

    PubMed

    Coutté, Alexandre; Olivier, Gérard; Faure, Sylvane; Baccino, Thierry

    2014-08-01

    This study examined the links between attention, hand movements and eye movements when performed in different spatial areas. Participants performed a visual search task on a computer screen while preparing to press two keyboard keys sequentially with their index. Results showed that the planning of the manual sequence influenced the latency of the first saccade and the placement of the first fixation. In particular, even if the first fixation placement was influenced by the combination of both components of the prepared manual sequence in some trials, it was affected principally by the first component of the prepared manual sequence. Moreover, the probability that the first fixation placement did reflect a combination of both components of the manual sequence was correlated with the speed of the second component. This finding suggests that the preparation of the second component of the sequence influence simultaneous oculomotor behavior when motor control of the manual sequence relied on proactive motor planning. These results are discussed taking into account the current debate on the eye/hand coordination research.

  4. Thermal/structural Tailoring of Engine Blades (T/SEAEBL). Theoretical Manual

    NASA Technical Reports Server (NTRS)

    Brown, K. W.; Clevenger, W. B.

    1994-01-01

    The Thermal/Structural Tailoring of Engine Blades (T/STAEBL) system is a family of computer programs executed by a control program. The T/STAEBL system performs design optimizations of cooled, hollow turbine blades and vanes. This manual describes the T/STAEBL data block structure and system organization. The approximate analysis and optimization modules are detailed, and a validation test case is provided.

  5. Thermal/structural tailoring of engine blades (T/SEAEBL). Theoretical manual

    NASA Astrophysics Data System (ADS)

    Brown, K. W.; Clevenger, W. B.

    1994-03-01

    The Thermal/Structural Tailoring of Engine Blades (T/STAEBL) system is a family of computer programs executed by a control program. The T/STAEBL system performs design optimizations of cooled, hollow turbine blades and vanes. This manual describes the T/STAEBL data block structure and system organization. The approximate analysis and optimization modules are detailed, and a validation test case is provided.

  6. Highly automated driving, secondary task performance, and driver state.

    PubMed

    Merat, Natasha; Jamson, A Hamish; Lai, Frank C H; Carsten, Oliver

    2012-10-01

    A driving simulator study compared the effect of changes in workload on performance in manual and highly automated driving. Changes in driver state were also observed by examining variations in blink patterns. With the addition of a greater number of advanced driver assistance systems in vehicles, the driver's role is likely to alter in the future from an operator in manual driving to a supervisor of highly automated cars. Understanding the implications of such advancements on drivers and road safety is important. A total of 50 participants were recruited for this study and drove the simulator in both manual and highly automated mode. As well as comparing the effect of adjustments in driving-related workload on performance, the effect of a secondary Twenty Questions Task was also investigated. In the absence of the secondary task, drivers' response to critical incidents was similar in manual and highly automated driving conditions. The worst performance was observed when drivers were required to regain control of driving in the automated mode while distracted by the secondary task. Blink frequency patterns were more consistent for manual than automated driving but were generally suppressed during conditions of high workload. Highly automated driving did not have a deleterious effect on driver performance, when attention was not diverted to the distracting secondary task. As the number of systems implemented in cars increases, an understanding of the implications of such automation on drivers' situation awareness, workload, and ability to remain engaged with the driving task is important.

  7. Manual for guided home exercises for osteoarthritis of the knee

    PubMed Central

    de Almeida Carvalho, Nilza Aparecida; Bittar, Simoni Teixeira; de Souza Pinto, Flávia Ribeiro; Ferreira, Mônica; Sitta, Robson Roberto

    2010-01-01

    INTRODUCTION: Physiotherapy is one of the most important components of therapy for osteoarthritis of the knee. The objective of this prospective case series was to assess the efficiency of a guidance manual for patients with osteoarthritis of the knee in relation to pain, range of movement , muscle strength and function, active goniometry, manual strength test and function. METHODS: Thirty-eight adults with osteoarthritis of the knee (≥ 45 years old) who were referred to the physiotherapy service at the university hospital (Santa Casa de Misericórdia de São Paulo) were studied. Patients received guidance for the practice of specific physical exercises and a manual with instructions on how to perform the exercises at home. They were evaluated for pain, range of movement, muscle strength and function. These evaluations were performed before they received the manual and three months later. Patients were seen monthly regarding improvements in their exercising abilities. RESULTS: The program was effective for improving muscle strength, controlling pain, maintaining range of movement of the knee joint, and reducing functional incapacity. DISCUSSION: A review of the literature showed that there are numerous clinical benefits to the regular practice of physical therapy exercises by patients with osteoarthritis of the knee(s) in a program with appropriate guidance. This study shows that this guidance can be attained at home with the use of a proper manual. CONCLUSIONS: Even when performed at home without constant supervision, the use of the printed manual for orientation makes the exercises for osteoarthritis of the knee beneficial. PMID:20835554

  8. Programmer's manual for the Mission Analysis Evaluation and Space Trajectory Operations program (MAESTRO)

    NASA Technical Reports Server (NTRS)

    Lutzky, D.; Bjorkman, W. S.

    1973-01-01

    The Mission Analysis Evaluation and Space Trajectory Operations program known as MAESTRO is described. MAESTRO is an all FORTRAN, block style, computer program designed to perform various mission control tasks. This manual is a guide to MAESTRO, providing individuals the capability of modifying the program to suit their needs. Descriptions are presented of each of the subroutines descriptions consist of input/output description, theory, subroutine description, and a flow chart where applicable. The programmer's manual also contains a detailed description of the common blocks, a subroutine cross reference map, and a general description of the program structure.

  9. Effects of Different Heave Motion Components on Pilot Pitch Control Behavior

    NASA Technical Reports Server (NTRS)

    Zaal, Petrus M. T.; Zavala, Melinda A.

    2016-01-01

    The study described in this paper had two objectives. The first objective was to investigate if a different weighting of heave motion components decomposed at the center of gravity, allowing for a higher fidelity of individual components, would result in pilot manual pitch control behavior and performance closer to that observed with full aircraft motion. The second objective was to investigate if decomposing the heave components at the aircraft's instantaneous center of rotation rather than at the center of gravity could result in additional improvements in heave motion fidelity. Twenty-one general aviation pilots performed a pitch attitude control task in an experiment conducted on the Vertical Motion Simulator at NASA Ames under different hexapod motion conditions. The large motion capability of the Vertical Motion Simulator also allowed for a full aircraft motion condition, which served as a baseline. The controlled dynamics were of a transport category aircraft trimmed close to the stall point. When the ratio of center of gravity pitch heave to center of gravity heave increased in the hexapod motion conditions, pilot manual control behavior and performance became increasingly more similar to what is observed with full aircraft motion. Pilot visual and motion gains significantly increased, while the visual lead time constant decreased. The pilot visual and motion time delays remained approximately constant and decreased, respectively. The neuromuscular damping and frequency both decreased, with their values more similar to what is observed with real aircraft motion when there was an equal weighting of the heave of the center of gravity and heave due to rotations about the center of gravity. In terms of open- loop performance, the disturbance and target crossover frequency increased and decreased, respectively, and their corresponding phase margins remained constant and increased, respectively. The decomposition point of the heave components only had limited effects on pilot manual control behavior and performance.

  10. Traffic control and work zone safety for high volume roads.

    DOT National Transportation Integrated Search

    2012-07-01

    The Manual on Uniform Traffic Control Devices (MUTCD) predominantly addresses work performed : along the centerline of roadways and low-speed roads. This work does not apply to the majority of : situations encountered by New Jersey Department of Tran...

  11. The effect of acute exercise and psychosocial stress on fine motor skills and testosterone concentration in the saliva of high school students.

    PubMed

    Wegner, Mirko; Koedijker, Johan M; Budde, Henning

    2014-01-01

    Little is known about the influence of different stressors on fine motor skills, the concentration of testosterone (T), and their interaction in adolescents. Therefore, 62 high school students aged 14-15 years were randomly assigned to two experimental groups (exercise, psychosocial stress) and a control group. Exercise stress was induced at 65-75% of the maximum heart rate by running for 15 minutes (n = 24). Psychosocial stress was generated by an intelligence test (HAWIK-IV), which was uncontrollable and characterized by social-evaluative-threat to the students (n = 21). The control group followed was part of a regular school lesson with the same duration (n = 28). Saliva was collected after a normal school lesson (pre-test) as well as after the intervention/control period (post-test) and was analyzed for testosterone. Fine motor skills were assessed pre- and post-intervention using a manual dexterity test (Flower Trail) from the Movement Assessment Battery for Children-2. A repeated measure ANCOVA including gender as a covariate revealed a significant group by test interaction, indicating an increase in manual dexterity only for the psychosocial stress group. Correlation analysis of all students shows that the change of testosterone from pre- to post-test was directly linked (r = -.31, p = .01) to the changes in manual dexterity performance. Participants showing high increases in testosterone from pre- to post-test made fewer mistakes in the fine motor skills task. Findings suggest that manual dexterity increases when psychosocial stress is induced and that improvement of manual dexterity performance corresponds with the increase of testosterone.

  12. INTEGRATED AIR POLLUTION CONTROL SYSTEM VERSION 5.0 - VOLUME 3: PROGRAMMER'S MAINTENANCE MANUAL

    EPA Science Inventory

    The three volume report and two diskettes document the Integrated Air Pollution Control System (IAPCS), developed for the U.S. EPA to estimate costs and performance for emission control systems applied to coal-fired utility boilers. The model can project a material balance, an eq...

  13. INTEGRATED AIR POLLUTION CONTROL SYSTEM, VERSION 4.0 - VOLUME 3: PROGRAMMER'S MAINTENACE MANUAL

    EPA Science Inventory

    The Integrated Air Pollution Control System (IAPCS) was developed for the U.S. EPA's Air and Energy Engineering Research Laboratory to estimate costs and performance for emission control systems applied to coal-fired utility boilers. The model can project a material balance, and ...

  14. INTEGRATED AIR POLLUTION CONTROL SYSTEM, VERSION 4.0 - VOLUME 2: TECHNICAL DOCUMENTATION MANUAL

    EPA Science Inventory

    The Integrated Air Pollution Control System (IAPCS) was developed for the U.S. EPA's Air and Energy Engineering Research Laboratory to estimate costs and performance for emission control systems applied to coal-fired utility boilers. The model can project a material balance, and ...

  15. Patient-specific positioning guides versus manual instrumentation for total knee arthroplasty: an intraoperative comparison.

    PubMed

    Kassab, Safa; Pietrzak, William S

    2014-01-01

    Traditional manual instruments for total knee arthroplasty are associated with a malalignment rate of nearly 30%. Patient-specific positioning guides, developed to help address alignment, may also influence other intraoperative factors. This study compared a consecutive series of 270 Vanguard total knee replacements performed with Signature patient-specific positioning guides (study group) to a consecutive series of 595 similar knee replacements performed with manual instrumentation (control group). The study group averaged 16.7 fewer minutes in the operating room (p < .001), utilized tibial inserts that averaged 0.4 mm thinner with a smaller proportion of "thick" tibial inserts (14-18 mm) (p < .001), and required fewer transfusions (p = .022). The Signature-derived surgical plan accurately predicted correct femoral and tibial component sizes in 86.3% and 70.3% of the cases, respectively. These rates increased to 99.3% and 99.2%, respectively, for accuracy to within one size of the surgical plan, similar to published values for manual instrumentation.

  16. Differences in Learning Volitional (Manual) and Non-Volitional (Posture) Aspects of a Complex Motor Skill in Young Adult Dyslexic and Skilled Readers

    PubMed Central

    Sela, Itamar; Karni, Avi

    2012-01-01

    The ‘Cerebellar Deficit Theory’ of developmental dyslexia proposes that a subtle developmental cerebellar dysfunction leads to deficits in attaining ‘automatic’ procedures and therefore manifests as subtle motor impairments (e.g., balance control, motor skill learning) in addition to the reading and phonological difficulties. A more recent version of the theory suggests a core deficit in motor skill acquisition. This study was undertaken to compare the time-course and the nature of practice-related changes in volitional (manual) and non-volitional (posture) motor performance in dyslexic and typical readers while learning a new movement sequence. Seventeen dyslexic and 26 skilled young adult readers underwent a three-session training program in which they practiced a novel sequence of manual movements while standing in a quiet stance position. Both groups exhibited robust and well-retained gains in speed, with no loss of accuracy, on the volitional, manual, aspects of the task, with a time-course characteristic of procedural learning. However, the dyslexic readers exhibited a pervasive slowness in the initiation of volitional performance. In addition, while typical readers showed clear and well-retained task-related adaptation of the balance and posture control system, the dyslexic readers had significantly larger sway and variance of sway throughout the three sessions and were less efficient in adapting the posture control system to support the acquisition of the novel movement sequence. These results support the notion of a non-language-related deficit in developmental dyslexia, one related to the recruitment of motor systems for effective task performance rather than to a general motor learning disability. PMID:23049736

  17. Effect of time span and task load on pilot mental workload

    NASA Technical Reports Server (NTRS)

    Berg, S. L.; Sheridan, T. B.

    1986-01-01

    Two sets of simulations designed to examine how a pilot's mental workload is affected by continuous manual-control activity versus discrete mental tasks that included the length of time between receiving an assignment and executing it are described. The first experiment evaluated two types of measures: objective performance indicators and subjective ratings. Subjective ratings for the two missions were different, but the objective performance measures were similar. In the second experiments, workload levels were increased and a second performance measure was taken. Mental workload had no influence on either performance-based workload measure. Subjective ratings discriminated among the scenarios and correlated with performance measures for high-workload flights. The number of mental tasks performed did not influence error rates, although high manual workloads did increase errors.

  18. Improving transcriptome construction in non-model organisms: integrating manual and automated gene definition in Emiliania huxleyi.

    PubMed

    Feldmesser, Ester; Rosenwasser, Shilo; Vardi, Assaf; Ben-Dor, Shifra

    2014-02-22

    The advent of Next Generation Sequencing technologies and corresponding bioinformatics tools allows the definition of transcriptomes in non-model organisms. Non-model organisms are of great ecological and biotechnological significance, and consequently the understanding of their unique metabolic pathways is essential. Several methods that integrate de novo assembly with genome-based assembly have been proposed. Yet, there are many open challenges in defining genes, particularly where genomes are not available or incomplete. Despite the large numbers of transcriptome assemblies that have been performed, quality control of the transcript building process, particularly on the protein level, is rarely performed if ever. To test and improve the quality of the automated transcriptome reconstruction, we used manually defined and curated genes, several of them experimentally validated. Several approaches to transcript construction were utilized, based on the available data: a draft genome, high quality RNAseq reads, and ESTs. In order to maximize the contribution of the various data, we integrated methods including de novo and genome based assembly, as well as EST clustering. After each step a set of manually curated genes was used for quality assessment of the transcripts. The interplay between the automated pipeline and the quality control indicated which additional processes were required to improve the transcriptome reconstruction. We discovered that E. huxleyi has a very high percentage of non-canonical splice junctions, and relatively high rates of intron retention, which caused unique issues with the currently available tools. While individual tools missed genes and artificially joined overlapping transcripts, combining the results of several tools improved the completeness and quality considerably. The final collection, created from the integration of several quality control and improvement rounds, was compared to the manually defined set both on the DNA and protein levels, and resulted in an improvement of 20% versus any of the read-based approaches alone. To the best of our knowledge, this is the first time that an automated transcript definition is subjected to quality control using manually defined and curated genes and thereafter the process is improved. We recommend using a set of manually curated genes to troubleshoot transcriptome reconstruction.

  19. Speech responses and dual-task performance - Better time-sharing or asymmetric transfer?

    NASA Technical Reports Server (NTRS)

    Vidulich, Michael A.

    1988-01-01

    The value of speech controls in a dual-task experiment that also evaluated asymmetric transfer effects is considered. There was no evidence of asymmetric transfer in spite of significant effects supporting the advantage of mixing manual and speech responses. The data suggest that speech controls can be used to enhance performance in operational multiple-task environments.

  20. 46 CFR 62.25-10 - Manual alternate control systems.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... automatic primary control system failure; (2) Be suitable for manual control for prolonged periods; (3) Be... 46 Shipping 2 2011-10-01 2011-10-01 false Manual alternate control systems. 62.25-10 Section 62.25... AUTOMATION General Requirements for All Automated Vital Systems § 62.25-10 Manual alternate control systems...

  1. A manual control theory analysis of vertical situation displays for STOL aircraft

    NASA Technical Reports Server (NTRS)

    Baron, S.; Levison, W. H.

    1973-01-01

    Pilot-vehicle-display systems theory is applied to the analysis of proposed vertical situation displays for manual control in approach-to-landing of a STOL aircraft. The effects of display variables on pilot workload and on total closed-loop system performance was calculated using an optimal-control model for the human operator. The steep approach of an augmentor wing jet STOL aircraft was analyzed. Both random turbulence and mean-wind shears were considered. Linearized perturbation equations were used to describe longitudinal and lateral dynamics of the aircraft. The basic display configuration was one that abstracted the essential status information (including glide-slope and localizer errors) of an EADI display. Proposed flight director displays for both longitudinal and lateral control were also investigated.

  2. Dynamic Stability Instrumentation System (DSIS). Volume 3; User Manual

    NASA Technical Reports Server (NTRS)

    Daniels, Taumi S.; Boyden, Richmond P.; Dress, David A.; Jordan, Thomas L.

    1996-01-01

    The paper is an operating manual for the Dynamic Stability Instrumentation System in specific NASA Langley wind tunnels. The instrumentation system performs either a synchronous demodulation or a Fast Fourier Transform on dynamic balance strain gage signals, and ultimately computes aerodynamic coefficients. The dynamic balance converts sting motor rotation into pitch or yaw plane or roll axis oscillation, with timing information provided by a shaft encoder. Additional instruments control model attitude and balance temperature and monitor sting vibrations. Other instruments perform self-calibration and diagnostics. Procedures for conducting calibrations and wind-off and wind-on tests are listed.

  3. Multivariable manual control with simultaneous visual and auditory presentation of information. [for improved compensatory tracking performance of human operator

    NASA Technical Reports Server (NTRS)

    Uhlemann, H.; Geiser, G.

    1975-01-01

    Multivariable manual compensatory tracking experiments were carried out in order to determine typical strategies of the human operator and conditions for improvement of his performance if one of the visual displays of the tracking errors is supplemented by an auditory feedback. Because the tracking error of the system which is only visually displayed is found to decrease, but not in general that of the auditorally supported system, it was concluded that the auditory feedback unloads the visual system of the operator who can then concentrate on the remaining exclusively visual displays.

  4. A Model of Manual Control with Perspective Scene Viewing

    NASA Technical Reports Server (NTRS)

    Sweet, Barbara Townsend

    2013-01-01

    A model of manual control during perspective scene viewing is presented, which combines the Crossover Model with a simpli ed model of perspective-scene viewing and visual- cue selection. The model is developed for a particular example task: an idealized constant- altitude task in which the operator controls longitudinal position in the presence of both longitudinal and pitch disturbances. An experiment is performed to develop and vali- date the model. The model corresponds closely with the experimental measurements, and identi ed model parameters are highly consistent with the visual cues available in the perspective scene. The modeling results indicate that operators used one visual cue for position control, and another visual cue for velocity control (lead generation). Additionally, operators responded more quickly to rotation (pitch) than translation (longitudinal).

  5. Commentary on “Performance of a Glucose Meter with a Built-In Automated Bolus Calculator versus Manual Bolus Calculation in Insulin-Using Subjects”

    PubMed Central

    Rossetti, Paolo; Vehí, Josep; Revert, Ana; Calm, Remei; Bondia, Jorge

    2012-01-01

    Since the early 2000s, there has been an exponentially increasing development of new diabetes-applied technology, such as continuous glucose monitoring, bolus calculators, and “smart” pumps, with the expectation of partially overcoming clinical inertia and low patient compliance. However, its long-term efficacy in glucose control has not been unequivocally proven. In this issue of Journal of Diabetes Science and Technology, Sussman and colleagues evaluated a tool for the calculation of the prandial insulin dose. A total of 205 insulin-treated patients were asked to compute a bolus dose in two simulated conditions either manually or with the bolus calculator built into the FreeStyle InsuLinx meter, revealing the high frequency of wrong calculations when performed manually. Although the clinical impact of this study is limited, it highlights the potential implications of low diabetes-related numeracy in poor glycemic control. Educational programs aiming to increase patients’ empowerment and caregivers’ knowledge are needed in order to get full benefit of the technology. PMID:22538145

  6. Improvement in children's fine motor skills following a computerized typing intervention.

    PubMed

    McGlashan, Hannah L; Blanchard, Caroline C V; Sycamore, Nicole J; Lee, Rachel; French, Blandine; Holmes, Nicholas P

    2017-12-01

    Children spend a large proportion of their school day engaged in tasks that require manual dexterity. If children experience difficulties with their manual dexterity skills it can have a consequential effect on their academic achievement. The first aim of this paper was to explore whether an online interactive typing intervention could improve children's scores on a standardised measure of manual dexterity. The second aim was to implement a serial reaction time tapping task as an index of children's finger movement learning, and to see whether performance on this task would improve after the intervention. Seventy-eight typically developing children aged between 8 and 10 were tested at their school on the pre-intervention Movement Assessment Battery for Children (2nd edition; MABC-2) and tapping tasks. Twenty-eight of these children volunteered to be randomly allocated to the intervention or control group. Children in the intervention group had a choice of two online games to play at home over a period of four weeks, while the children in the control group were not given these games to play. The intervention and control groups were then re-tested on the MABC-2 manual dexterity and the tapping task. Children in the intervention group significantly improved their manual dexterity scores in the MABC-2 compared to the control group. On average, all children learnt the tapping sequence, however, there were no group differences and no effect of the intervention on the tapping task. These results have important implications for implementing a freely available, easy to administer, fun and interactive intervention to help children improve their manual dexterity skills. Copyright © 2017 The Authors. Published by Elsevier B.V. All rights reserved.

  7. Multimodal corridor and capacity analysis manual. Final report

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    NONE

    1998-12-31

    This report presents the results of research carried out under NCHRP Project 8-31, Long-Term Availability of Multimodal Corridor Capacity. The report is presented as a manual on multimodal corridor and capacity analysis. Because transportation-system and corridor capacity for freight and passengers is critical for meeting current and future transportation demand, this manual will provide much needed assistance to a wide range of practitioners, particularly those engaged in performance analysis, capacity management, needs studies, systems planning, and corridor development planning--including major investment studies. It provides information regarding capacity analysis approaches for highways, rail, pipelines, and waterways and presents available options formore » enhancing corridor capacity and performance through various strategies such as new capacity development, freeing up unused capacity, or control of travel demand. Evaluation methods for these options are included.« less

  8. 42 CFR 493.1269 - Standard: Hematology.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... materials must be tested in duplicate. (b) For all nonmanual coagulation test systems, the laboratory must...) For manual coagulation tests— (1) Each individual performing tests must test two levels of control...

  9. 42 CFR 493.1269 - Standard: Hematology.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... materials must be tested in duplicate. (b) For all nonmanual coagulation test systems, the laboratory must...) For manual coagulation tests— (1) Each individual performing tests must test two levels of control...

  10. 42 CFR 493.1269 - Standard: Hematology.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... materials must be tested in duplicate. (b) For all nonmanual coagulation test systems, the laboratory must...) For manual coagulation tests— (1) Each individual performing tests must test two levels of control...

  11. 42 CFR 493.1269 - Standard: Hematology.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... materials must be tested in duplicate. (b) For all nonmanual coagulation test systems, the laboratory must...) For manual coagulation tests— (1) Each individual performing tests must test two levels of control...

  12. 42 CFR 493.1269 - Standard: Hematology.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... materials must be tested in duplicate. (b) For all nonmanual coagulation test systems, the laboratory must...) For manual coagulation tests— (1) Each individual performing tests must test two levels of control...

  13. Manual versus sonic-powered toothbrushing for plaque reduction in patients with dental implants: an explanatory randomised controlled trial.

    PubMed

    Swierkot, Katrin; Brusius, Manuel; Leismann, Diana; Nonnenmacher, Claudia; Nüsing, Rolf; Lubbe, Dirk; Schade-Brittinger, Carmen; Mengel, Reiner

    2013-01-01

    The aim of the present study was to investigate plaque levels following sonic-powered and manual toothbrushing in subjects with dental implants. This study included 36 male and 47 female partially edentulous patients (age range 45-78 years, mean age 59.8 years) that were randomly assigned to one of two treatment groups: the sonic toothbrush group (n = 42; Philips Sonicare FlexCare® toothbrush) or the manual toothbrush group (n = 41; Oral-B P40®). Clinical, microbiological and immunological examinations were performed blinded at baseline and after 3, 6, 9 and 12 months. Microbiological analyses were performed by real-time polymerase chain reaction. Immunological analyses (prostaglandin E2) were performed by chromatography-electrospray spectrometry. The plaque index difference between baseline and 12 months at implants showed no significant difference between sonic or manual toothbrushing in a two-sided Mann-Whitney test (W = 773.5, P = 0.426, 95% CI -0.64 to 0.20). At the end of the study, there were no significant changes in plaque index, bleeding on probing, gingival index, pocket probing depth, gingival recession, clinical attachment level or the microbiological and immunological outcomes at implants or teeth in either group. This study uncovered no significant difference between sonic and manual toothbrushing for plaque reduction at implants and teeth. Both toothbrushes maintain healthy peri-implant soft tissue.

  14. Movement Interferes with Visuospatial Working Memory during the Encoding: An ERP Study

    PubMed Central

    Gunduz Can, Rumeysa; Schack, Thomas; Koester, Dirk

    2017-01-01

    The present study focuses on the functional interactions of cognition and manual action control. Particularly, we investigated the neurophysiological correlates of the dual-task costs of a manual-motor task (requiring grasping an object, holding it, and subsequently placing it on a target) for working memory (WM) domains (verbal and visuospatial) and processes (encoding and retrieval). Thirty participants were tested in a cognitive-motor dual-task paradigm, in which a single block (a verbal or visuospatial WM task) was compared with a dual block (concurrent performance of a WM task and a motor task). Event-related potentials (ERPs) were analyzed separately for the encoding and retrieval processes of verbal and visuospatial WM domains both in single and dual blocks. The behavioral analyses show that the motor task interfered with WM and decreased the memory performance. The performance decrease was larger for the visuospatial task compared with the verbal task, i.e., domain-specific memory costs were obtained. The ERP analyses show the domain-specific interference also at the neurophysiological level, which is further process-specific to encoding. That is, comparing the patterns of WM-related ERPs in the single block and dual block, we showed that visuospatial ERPs changed only for the encoding process when a motor task was performed at the same time. Generally, the present study provides evidence for domain- and process-specific interactions of a prepared manual-motor movement with WM (visuospatial domain during the encoding process). This study, therefore, provides an initial neurophysiological characterization of functional interactions of WM and manual actions in a cognitive-motor dual-task setting, and contributes to a better understanding of the neuro-cognitive mechanisms of motor action control. PMID:28611714

  15. A users' guide to the trace contaminant control simulation computer program

    NASA Technical Reports Server (NTRS)

    Perry, J. L.

    1994-01-01

    The Trace Contaminant Control Simulation computer program is a tool for assessing the performance of various trace contaminant control technologies for removing trace chemical contamination from a spacecraft cabin atmosphere. The results obtained from the program can be useful in assessing different technology combinations, system sizing, system location with respect to other life support systems, and the overall life cycle economics of a trace contaminant control system. The user's manual is extracted in its entirety from NASA TM-108409 to provide a stand-alone reference for using any version of the program. The first publication of the manual as part of TM-108409 also included a detailed listing of version 8.0 of the program. As changes to the code were necessary, it became apparent that the user's manual should be separate from the computer code documentation and be general enough to provide guidance in using any version of the program. Provided in the guide are tips for input file preparation, general program execution, and output file manipulation. Information concerning source code listings of the latest version of the computer program may be obtained by contacting the author.

  16. Stabilization exercise compared to general exercises or manual therapy for the management of low back pain: A systematic review and meta-analysis.

    PubMed

    Gomes-Neto, Mansueto; Lopes, Jordana Moura; Conceição, Cristiano Sena; Araujo, Anderson; Brasileiro, Alécio; Sousa, Camila; Carvalho, Vitor Oliveira; Arcanjo, Fabio Luciano

    2017-01-01

    We performed a systematic review with a meta-analysis to examine the efficacy of stabilization exercises versus general exercises or manual therapy in patients with low back pain. We searched MEDLINE, Cochrane Controlled Trials, Scielo, and CINAHL (from the earliest date available to November 2014) for randomized controlled trials that examined the efficacy of stabilization exercises compared to general exercises or manual therapy on pain, disability, and function in patients with low back pain. Weighted mean differences (WMD) and 95% confidence intervals were calculated. Eleven studies met the inclusion criteria (413 stabilization exercises patients, 297 general exercises patients, and 185 manual therapy patients). Stabilization exercises may provide greater benefit than general exercise for pain reduction and improvement in disability. Stabilization exercise improved pain with a WMD of -1.03 (95% CI: -1.29 to -0.27) and improved disability with a WMD of -5.41 (95% CI: -8.34 to -2.49). There were no significant differences in pain and disability scores among participants in the stabilization exercise group compared to those in the manual therapy group. Stabilization exercises were as efficacious as manual therapy in decreasing pain and disability and should be encouraged as part of musculoskeletal rehabilitation for low back pain. Copyright © 2016 Elsevier Ltd. All rights reserved.

  17. The Effectiveness and Safety of Manual Therapy on Pain and Disability in Older Persons With Chronic Low Back Pain: A Systematic Review.

    PubMed

    de Luca, Katie E; Fang, Sheng Hung; Ong, Justin; Shin, Ki-Soo; Woods, Samuel; Tuchin, Peter J

    2017-09-01

    The aim of this study was to perform a systematic review of the literature of the effectiveness and safety of manual therapy interventions on pain and disability in older persons with chronic low back pain (LBP). A literature search of 4 electronic databases was performed (PubMed, EMBASE, OVID, and CINAHL). Inclusion criteria included randomized controlled trials of manual therapy interventions on older persons who had chronic LBP. Effectiveness was determined by extracting and examining outcomes for pain and disability, with safety determined by the report of adverse events. The PEDro scale was used for quality assessment of eligible studies. The search identified 405 articles, and 38 full-text articles were assessed. Four studies met the inclusion criteria. All trials were of good methodologic quality and had a low risk of bias. The included studies provided moderate evidence supporting the use of manual therapy to reduce pain levels and alleviate disability. A limited number of studies have investigated the effectiveness and safety of manual therapy in the management of older people with chronic LBP. The current evidence to make firm clinical recommendations is limited. Research with appropriately designed trials to investigate the effectiveness and safety of manual therapy interventions in older persons with chronic LBP is required. Copyright © 2017. Published by Elsevier Inc.

  18. Aging and Attentional Control

    PubMed Central

    Tsang, Pamela S.

    2013-01-01

    The research examines the structural bottleneck account and the resource account of the substantial dual-task deficits among older adults. Procedures from two common dual-task methodologies--the psychological refractory period and the relative-priority manipulation--were used to encourage maximization of the joint performance. Performance and time-sharing strategies from subjects between the ages of 20 and 70 were examined. Age-related declines in time-sharing efficiency and in the precision of the executive control process were observed. The age-related effect was larger when two manual responses were required than when one manual and one vocal response were required but no evidence for obligatory sequential processing was found. Except for the most demanding conditions, comparable practice effects were observed between the younger and older subjects, suggesting considerable cognitive plasticity in the older subjects. Implications for the two attentional accounts were discussed. PMID:23281799

  19. Manual traffic control for planned special events and emergencies.

    DOT National Transportation Integrated Search

    2015-11-01

    Manual traffic control is a common intersection control strategy in which trained personnel, : typically police law enforcement officers, allocate intersection right-of-way to approaching vehicles. : Manual intersection control is a key part of manag...

  20. Laboratory productivity and the rate of manual peripheral blood smear review: a College of American Pathologists Q-Probes study of 95,141 complete blood count determinations performed in 263 institutions.

    PubMed

    Novis, David A; Walsh, Molly; Wilkinson, David; St Louis, Mary; Ben-Ezra, Jonathon

    2006-05-01

    Automated laboratory hematology analyzers are capable of performing differential counts on peripheral blood smears with greater precision and more accurate detection of distributional and morphologic abnormalities than those performed by manual examinations of blood smears. Manual determinations of blood morphology and leukocyte differential counts are time-consuming, expensive, and may not always be necessary. The frequency with which hematology laboratory workers perform manual screens despite the availability of labor-saving features of automated analyzers is unknown. To determine the normative rates with which manual peripheral blood smears were performed in clinical laboratories, to examine laboratory practices associated with higher or lower manual review rates, and to measure the effects of manual smear review on the efficiency of generating complete blood count (CBC) determinations. From each of 3 traditional shifts per day, participants were asked to select serially, 10 automated CBC specimens, and to indicate whether manual scans and/or reviews with complete differential counts were performed on blood smears prepared from those specimens. Sampling continued until a total of 60 peripheral smears were reviewed manually. For each specimen on which a manual review was performed, participants indicated the patient's age, hemoglobin value, white blood cell count, platelet count, and the primary reason why the manual review was performed. Participants also submitted data concerning their institutions' demographic profiles and their laboratories' staffing, work volume, and practices regarding CBC determinations. The rates of manual reviews and estimations of efficiency in performing CBC determinations were obtained from the data. A total of 263 hospitals and independent laboratories, predominantly located in the United States, participating in the College of American Pathologists Q-Probes Program. There were 95,141 CBC determinations examined in this study; participants reviewed 15,423 (16.2%) peripheral blood smears manually. In the median institution (50th percentile), manual reviews of peripheral smears were performed on 26.7% of specimens. Manual differential count review rates were inversely associated with the magnitude of platelet counts that were required by laboratory policy to trigger smear reviews and with the efficiency of generating CBC reports. Lower manual differential count review rates were associated with laboratory policies that allowed manual reviews solely on the basis of abnormal automated red cell parameters and that precluded performing repeat manual reviews within designated time intervals. The manual scan rate elevated with increased number of hospital beds. In more than one third (35.7%) of the peripheral smears reviewed manually, participants claimed to have learned additional information beyond what was available on automated hematology analyzer printouts alone. By adopting certain laboratory practices, it may be possible to reduce the rates of manual reviews of peripheral blood smears and increase the efficiency of generating CBC results.

  1. Manual control analysis of drug effects on driving performance

    NASA Technical Reports Server (NTRS)

    Smiley, A.; Ziedman, K.; Moskowitz, H.

    1981-01-01

    The effects of secobarbital, diazepam, alcohol, and marihuana on car-driver transfer functions obtained using a driving simulator were studied. The first three substances, all CNS depressants, reduced gain, crossover frequency, and coherence which resulted in poorer tracking performance. Marihuana also impaired tracking performance but the only effect on the transfer function parameters was to reduce coherence.

  2. Twentieth Annual Conference on Manual Control, Volume 2

    NASA Technical Reports Server (NTRS)

    Hart, S. G. (Compiler); Hartzell, E. J. (Compiler)

    1984-01-01

    Volume II contains thirty two complete manuscripts and five abstracts. The topics covered include the application of event-related brain potential analysis to operational problems, the subjective evaluation of workload, mental models, training, crew interaction analysis, multiple task performance, and the measurement of workload and performance in simulation.

  3. User's manual for a computer program for the emulation/simulation of a space station Environmental Control and Life Support System (ESCM)

    NASA Technical Reports Server (NTRS)

    Yanosy, James L.

    1988-01-01

    This manual describes how to use the Emulation Simulation Computer Model (ESCM). Based on G189A, ESCM computes the transient performance of a Space Station atmospheric revitalization subsystem (ARS) with CO2 removal provided by a solid amine water desorbed subsystem called SAWD. Many performance parameters are computed some of which are cabin CO2 partial pressure, relative humidity, temperature, O2 partial pressure, and dew point. The program allows the user to simulate various possible combinations of man loading, metabolic profiles, cabin volumes and certain hypothesized failures that could occur.

  4. Interpersonal Biocybernetics: Connecting Through Social Psychophysiology

    NASA Technical Reports Server (NTRS)

    Pope, Alan T.; Stephens, Chad L.

    2012-01-01

    One embodiment of biocybernetic adaptation is a human-computer interaction system designed such that physiological signals modulate the effect that control of a task by other means, usually manual control, has on performance of the task. Such a modulation system enables a variety of human-human interactions based upon physiological self-regulation performance. These interpersonal interactions may be mixes of competition and cooperation for simulation training and/or videogame entertainment

  5. System design and installation for RS600 programmable control system for solar heating and cooling

    NASA Technical Reports Server (NTRS)

    1978-01-01

    Procedures for installing, operating, and maintaining a programmable control system which utilizes a F8 microprocessor to perform all timing, control, and calculation functions in order to customize system performance to meet individual requirements for solar heating, combined heating and cooling, and/or hot water systems are described. The manual discusses user configuration and options, displays, theory of operation, trouble-shooting procedures, and warranty and assistance. Wiring lists, parts lists, drawings, and diagrams are included.

  6. The impact of manual rotation of the occiput posterior position on spontaneous vaginal delivery rate: study protocol for a randomized clinical trial (RMOS).

    PubMed

    Verhaeghe, C; Parot-Schinkel, E; Bouet, P E; Madzou, S; Biquard, F; Gillard, P; Descamps, P; Legendre, G

    2018-02-14

    The frequency of posterior presentations (occiput of the fetus towards the sacrum of the mother) in labor is approximately 20% and, of this, 5% remain posterior until the end of labor. These posterior presentations are associated with higher rates of cesarean section and instrumental delivery. Manual rotation of a posterior position in order to rotate the fetus to an anterior position has been proposed in order to reduce the rate of instrumental fetal delivery. No randomized study has compared the efficacy of this procedure to expectant management. We therefore propose a monocentric, interventional, randomized, prospective study to show the superiority of vaginal delivery rates using the manual rotation of the posterior position at full dilation over expectant management. Ultrasound imaging of the presentation will be performed at full dilation on all the singleton pregnancies for which a clinical suspicion of a posterior position was raised at more than 37 weeks' gestation (WG). In the event of an ultrasound confirming a posterior position, the patient will be randomized into an experimental group (manual rotation) or a control group (expectative management with no rotation). For a power of 90% and the hypothesis that vaginal deliveries will increase by 20%, (10% of patients lost to follow-up) 238 patients will need to be included in the study. The primary endpoint will be the rate of spontaneous vaginal deliveries (expected rate without rotation: 60%). The secondary endpoints will be the rate of fetal extractions (cesarean or instrumental) and the maternal and fetal morbidity and mortality rates. The intent-to-treat study will be conducted over 24 months. Recruitment started in February 2017. To achieve the primary objective, we will perform a test comparing the number of spontaneous vaginal deliveries in the two groups using Pearson's chi-squared test (provided that the conditions for using this test are satisfactory in terms of numbers). In the event that this test cannot be performed, we will use Fisher's exact test. Given that the efficacy of manual rotation has not been proven with a high level of evidence, the practice of this technique is not systematically recommended by scholarly societies and is, therefore, rarely performed by obstetric gynecologists. If our hypothesis regarding the superiority of manual rotation is confirmed, our study will help change delivery practices in cases of posterior fetal position. An increase in the rates of vaginal delivery will help decrease the short- and long-term rates of morbidity and mortality following cesarean section. Manual rotation is a simple and effective method with a success rate of almost 90%. Several preliminary studies have shown that manual rotation is associated with reduced rates for fetal extraction and maternal complications: Shaffer has shown that the cesarean section rate is lower in patients for whom a manual rotation is performed successfully (2%) with a 9% rate of cesarean sections when manual rotation is performed versus 41% when it is not performed. Le Ray has shown that manual rotation significantly reduces vaginal delivery rates via fetal extraction (23.2% vs 38.7%, p < 0.01). However, manual rotation is not systematically performed due to the absence of proof of its efficacy in retrospective studies and quasi-experimental before/after studies. ClinicalTrials.gov, Identifier: NCT03009435 . Registered on 30 December 2016.

  7. Does the therapy manual or the therapist matter most in treatment of obsessive-compulsive disorder? A randomized controlled trial of exposure with response or ritual prevention in 118 patients.

    PubMed

    van Oppen, Patricia; van Balkom, Anton J L M; Smit, Johannes H; Schuurmans, Josien; van Dyck, Richard; Emmelkamp, Paul M G

    2010-09-01

    The importance of the therapist's education and experience for the successful behavior treatment of obsessive-compulsive disorder (OCD) has not been investigated. Data on the relative effectiveness of self-controlled versus therapist-controlled in vivo exposure with response or ritual prevention (ERP) have yielded conflicting results. The present study compared the effectiveness of 4 different modes of delivery of ERP in a referred sample of OCD patients. Of the 146 eligible OCD outpatients, 118 patients enrolled in this randomized controlled trial and were randomly assigned to (1) therapist-controlled ERP performed by experienced behavior therapists; (2) therapist-controlled ERP performed by master's students of clinical psychology; (3) self-controlled ERP performed by experienced behavior therapists; and (4) self-controlled ERP performed by master's students of clinical psychology. This trial was performed from January 1999 to January 2005. Our analyses revealed no significant differences in clinical outcome between any of the different modes of delivery of ERP at posttreatment. The different ERP modes of delivery were associated with significant pretreatment to posttreatment improvement on all measurements, with large effect sizes on the primary outcome measure, the Yale-Brown Obsessive Compulsive Scale. Our results indicate that clinically inexperienced master's students with no postgraduate training can be as capable as experienced and certified behavior therapists in treating OCD patients, as long as therapists adhere to a standardized treatment manual and adequate training and supervision is provided. In contrast to other studies, we did not find a supposed benefit of therapist-controlled ERP versus self-controlled ERP in patients with OCD. www.trialregister.nl Identifier: NTR1444. © Copyright 2010 Physicians Postgraduate Press, Inc.

  8. Nutrient Control Design Manual

    EPA Science Inventory

    The purpose of this EPA design manual is to provide updated, state‐of‐the‐technology design guidance on nitrogen and phosphorus control at municipal Wastewater Treatment Plants (WWTPs). Similar to previous EPA manuals, this manual contains extensive information on the principles ...

  9. EPA Air Pollution Control Cost Manual

    EPA Science Inventory

    EPA's Air Pollution Control Cost Manual provides guidance for the development of accurate and consistent costs for air pollution control devices. A long-standing document prepared by EPA, the Control Cost Manual focuses on point source and stationary area source air pollution con...

  10. Effects of transcranial direct current stimulation on the control of finger force during dexterous manipulation in healthy older adults.

    PubMed

    Parikh, Pranav J; Cole, Kelly J

    2015-01-01

    The contribution of poor finger force control to age-related decline in manual dexterity is above and beyond ubiquitous behavioral slowing. Altered control of the finger forces can impart unwanted torque on the object affecting its orientation, thus impairing manual performance. Anodal transcranial direct current stimulation (tDCS) over primary motor cortex (M1) has been shown to improve the performance speed on manual tasks in older adults. However, the effects of anodal tDCS over M1 on the finger force control during object manipulation in older adults remain to be fully explored. Here we determined the effects of anodal tDCS over M1 on the control of grip force in older adults while they manipulated an object with an uncertain mechanical property. Eight healthy older adults were instructed to grip and lift an object whose contact surfaces were unexpectedly made more or less slippery across trials using acetate and sandpaper surfaces, respectively. Subjects performed this task before and after receiving anodal or sham tDCS over M1 on two separate sessions using a cross-over design. We found that older adults used significantly lower grip force following anodal tDCS compared to sham tDCS. Friction measured at the finger-object interface remained invariant after anodal and sham tDCS. These findings suggest that anodal tDCS over M1 improved the control of grip force during object manipulation in healthy older adults. Although the cortical networks for representing objects and manipulative actions are complex, the reduction in grip force following anodal tDCS over M1 might be due to a cortical excitation yielding improved processing of object-specific sensory information and its integration with the motor commands for production of manipulative forces. Our findings indicate that tDCS has a potential to improve the control of finger force during dexterous manipulation in older adults.

  11. Automatic documentation system extension to multi-manufacturers' computers and to measure, improve, and predict software reliability. Appendix A and B

    NASA Technical Reports Server (NTRS)

    Simmons, D. B.

    1975-01-01

    A manual which explains how to use the DOMONIC command language is presented. The manual consists of the following sections: 1. Introduction 2. What You Must Know to Use DOMONIC 3. Functions of DOMONIC 4. Entering and Manipulating Data 5. Templates and Data Definitions 6. Recipes and Document Generation 7. Initiating A Project and 8. Entering and Changing Security Controls. The first four sections must be known by all DOMONIC users. Sections five, seven and eight describe functions normally used only by project management. Section six tells how to generate documents. The manual specifies what commands to use in performing each of the functions mentioned above.

  12. Radiometer Calibration and Characterization (RCC) User's Manual: Windows Version 4.0

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Andreas, Afshin M.; Wilcox, Stephen M.

    2016-02-29

    The Radiometer Calibration and Characterization (RCC) software is a data acquisition and data archival system for performing Broadband Outdoor Radiometer Calibrations (BORCAL). RCC provides a unique method of calibrating broadband atmospheric longwave and solar shortwave radiometers using techniques that reduce measurement uncertainty and better characterize a radiometer's response profile. The RCC software automatically monitors and controls many of the components that contribute to uncertainty in an instrument's responsivity. This is a user's manual and guide to the RCC software.

  13. The Windmill technique avoids manual removal of the retained placenta-A new solution for an old problem.

    PubMed

    Hinkson, Larry; Suermann, Mia Amelie; Hinkson, Susan; Henrich, Wolfgang

    2017-08-01

    The primary objective is to assess the reduction in manual removal of placenta with the Windmill technique of placenta delivery in patients with retained placenta. The Windmill technique involves the application of continuous 360° umbilical cord traction and rotation in such a manner as to be perpendicular to the direction of the birth canal at the level of the introitus. This rotation through 360° is repeated slowly with movement akin to the motion of the blades of a windmill. We performed a 3-year retrospective case-control study at the Charité University Hospital in Berlin. Patients with a retained placenta more than 30min following failed traditional interventions were consented and offered the Windmill technique of placenta delivery. Study cases were compared to controls where an operative manual removal of placenta was performed. Patients with suspected placenta implantation problems, uterine atony, bleeding due to vaginal tract injury and coagulation disturbances were excluded. Over the study period 14 patients were recruited to the study arm and 17 patients were in the control group. With the Windmill technique for retained placenta, 86% (12/14, p<0.001) of patients avoided invasive operative manual removal of the placenta in theatre. There was a statistically significant reduction in mean blood loss (429ml vs 724ml, p=0.001) and mean postoperative fall in hemoglobin values (1.3g/dl vs 2.5g/dl, p=0.04). There was a reduction in the time to delivery of the placenta, antibiotic prophylaxis and use of general anesthesia. The Windmill technique for the delivery of the retained placenta is a simple, safe, effective and easy to teach technique that reduces invasive operative manual removal of the placenta, postpartum blood loss and delay in the placenta delivery. This innovative technique can also be a lifesaving intervention especially in areas with limited or no access to operative facilities. Copyright © 2017 Elsevier B.V. All rights reserved.

  14. Scalability of Robotic Controllers: An Evaluation of Controller Options-Experiment III

    DTIC Science & Technology

    2012-04-01

    NUMBER 7. PERFORMING ORGANIZATION NAME(S) AND ADDRESS(ES) U.S. Army Research Laboratory ATTN: RDRL- HRM -DW Aberdeen Proving Ground, MD 21005-5425...In this condition, the operator manually controlled all the robotic functions using a COTS Microsoft Xbox* 360 game controller (figure 3). The...Xbox is a trademark of Microsoft Corporation. 5 Figure 3. Game controller (GC/MC). 2.2.3.2 Virtual

  15. Manual therapy as an effective treatment for fibrosis in a rat model of upper extremity overuse injury

    PubMed Central

    Bove, Geoffrey M.; Harris, Michele Y; Zhao, Huaqing; Barbe, Mary F.

    2016-01-01

    Key clinical features of carpal tunnel syndrome and other types of cumulative trauma disorders of the hand and wrist include pain and functional disabilities. Mechanistic details remain under investigation but may involve tissue inflammation and/or fibrosis. We examined the effectiveness of modeled manual therapy (MMT) as a treatment for sensorimotor behavior declines and increased fibrogenic processes occurring in forearm tissues of rats performing an high repetition high force (HRHF) reaching and grasping task for 12 weeks. Young adult, female rats were examined: food restricted control rats (FRC, n=12); rats that were trained for 6 weeks before performing the HRHF task for 12 weeks with no treatment (HRHF-CON, n=11); and HRHF task rats received modeled manual therapy (HRHF-MMT, n=5) for 5 days/week for the duration of the 12-week of task. Rats receiving the MMT expressed fewer discomfort-related behaviors, and performed progressively better in the HRHF task. Grip strength, while decreased after training, improved following MMT. Fibrotic nerve and connective tissue changes (increased collagen and TGF-β1 deposition) present in 12-week HRHF-CON rats were significantly decreased in 12-week HRHF-MMT rats. These observations support the investigation of manual therapy as a preventative for repetitive motion disorders. PMID:26810536

  16. Management of Chronic Lateral Epicondylitis With Manual Therapy and Local Cryostimulation: A Pilot Study.

    PubMed

    Richer, Nadia; Marchand, Andrée-Anne; Descarreaux, Martin

    2017-12-01

    The purpose of this pilot study was to evaluate the feasibility and efficacy of adding cryostimulation to manual therapy in patients with chronic lateral epicondylitis. The control group (n = 19) was treated with manual therapy consisting of soft-tissue therapy and radial head mobilizations. The experimental group (n = 18) received cryostimulation in addition to manual therapy care similar to that for the control group. Both protocols consisted of 8 treatments over a 4-week period. Outcome measures included pain intensity (visual analog scale), pain-free grip strength (handheld dynamometer), and functional index (Patient-Rated Tennis Elbow Evaluation questionnaire). Assessments were performed at baseline, postintervention, and 3-month follow-up. Adherence and dropout rates were also considered. Both groups exhibited significant improvements in pain intensity and functional index at postintervention assessments, which were maintained at follow-up. All participants attended the prescribed number of treatments, but 27% were lost at follow-up. Minor adverse events were reported after cryostimulation in 4 cases. This study indicated that it is feasible to complete a clinical trial evaluating the efficacy of adding cryostimulation to manual therapy in patients with chronic lateral epicondylitis. On the basis of these preliminary data, the combination of cryostimulation and manual therapy care did not provide any additional benefits in both the short term and the long term. Manual myofascial point treatment and mobilization techniques yielded positive outcomes in chronic lateral epicondylitis. Further studies should focus on the sole therapeutic effect of cryostimulation in both patients with acute and those with chronic conditions.

  17. Nutrient Control Design Manual

    EPA Science Inventory

    The Nutrient Control Design Manual will present an extensive state-of-the-technology review of the engineering design and operation of nitrogen and phosphorous control technologies and techniques applied at municipal wastewater treatment plants (WWTPs). This manual will present ...

  18. Gait parameter control timing with dynamic manual contact or visual cues

    PubMed Central

    Shi, Peter; Werner, William

    2016-01-01

    We investigated the timing of gait parameter changes (stride length, peak toe velocity, and double-, single-support, and complete step duration) to control gait speed. Eleven healthy participants adjusted their gait speed on a treadmill to maintain a constant distance between them and a fore-aft oscillating cue (a place on a conveyor belt surface). The experimental design balanced conditions of cue modality (vision: eyes-open; manual contact: eyes-closed while touching the cue); treadmill speed (0.2, 0.4, 0.85, and 1.3 m/s); and cue motion (none, ±10 cm at 0.09, 0.11, and 0.18 Hz). Correlation analyses revealed a number of temporal relationships between gait parameters and cue speed. The results suggest that neural control ranged from feedforward to feedback. Specifically, step length preceded cue velocity during double-support duration suggesting anticipatory control. Peak toe velocity nearly coincided with its most-correlated cue velocity during single-support duration. The toe-off concluding step and double-support durations followed their most-correlated cue velocity, suggesting feedback control. Cue-tracking accuracy and cue velocity correlations with timing parameters were higher with the manual contact cue than visual cue. The cue/gait timing relationships generalized across cue modalities, albeit with greater delays of step-cycle events relative to manual contact cue velocity. We conclude that individual kinematic parameters of gait are controlled to achieve a desired velocity at different specific times during the gait cycle. The overall timing pattern of instantaneous cue velocities associated with different gait parameters is conserved across cues that afford different performance accuracies. This timing pattern may be temporally shifted to optimize control. Different cue/gait parameter latencies in our nonadaptation paradigm provide general-case evidence of the independent control of gait parameters previously demonstrated in gait adaptation paradigms. PMID:26936979

  19. 14 CFR 29.1587 - Performance information.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... 14 Aeronautics and Space 1 2011-01-01 2011-01-01 false Performance information. 29.1587 Section 29... Manual § 29.1587 Performance information. Flight manual performance information which exceeds any... rotorcraft, the Rotorcraft Flight Manual must contain a summary of the performance data, including data...

  20. 14 CFR 29.1587 - Performance information.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... 14 Aeronautics and Space 1 2010-01-01 2010-01-01 false Performance information. 29.1587 Section 29... Manual § 29.1587 Performance information. Flight manual performance information which exceeds any... rotorcraft, the Rotorcraft Flight Manual must contain a summary of the performance data, including data...

  1. 14 CFR 29.1587 - Performance information.

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... 14 Aeronautics and Space 1 2012-01-01 2012-01-01 false Performance information. 29.1587 Section 29... Manual § 29.1587 Performance information. Flight manual performance information which exceeds any... rotorcraft, the Rotorcraft Flight Manual must contain a summary of the performance data, including data...

  2. 14 CFR 29.1587 - Performance information.

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... 14 Aeronautics and Space 1 2013-01-01 2013-01-01 false Performance information. 29.1587 Section 29... Manual § 29.1587 Performance information. Flight manual performance information which exceeds any... rotorcraft, the Rotorcraft Flight Manual must contain a summary of the performance data, including data...

  3. The control of manual entry accuracy in management/engineering information systems, phase 1

    NASA Technical Reports Server (NTRS)

    Hays, Daniel; Nocke, Henry; Wilson, Harold; Woo, John, Jr.; Woo, June

    1987-01-01

    It was shown that clerical personnel can be tested for proofreading performance under simulated industrial conditions. A statistical study showed that errors in proofreading follow an extreme value probability theory. The study showed that innovative man/machine interfaces can be developed to improve and control accuracy during data entry.

  4. The manual control of vehicles undergoing slow transitions in dynamic characteristics

    NASA Technical Reports Server (NTRS)

    Moriarty, T. E.

    1974-01-01

    The manual control was studied of a vehicle with slowly time-varying dynamics to develop analytic and computer techniques necessary for the study of time-varying systems. The human operator is considered as he controls a time-varying plant in which the changes are neither abrupt nor so slow that the time variations are unimportant. An experiment in which pilots controlled the longitudinal mode of a simulated time-varying aircraft is described. The vehicle changed from a pure double integrator to a damped second order system, either instantaneously or smoothly over time intervals of 30, 75, or 120 seconds. The regulator task consisted of trying to null the error term resulting from injected random disturbances with bandwidths of 0.8, 1.4, and 2.0 radians per second. Each of the twelve experimental conditons was replicated ten times. It is shown that the pilot's performance in the time-varying task is essentially equivalent to his performance in stationary tasks which correspond to various points in the transition. A rudimentary model for the pilot-vehicle-regulator is presented.

  5. Radiological control manual. Revision 1

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Kloepping, R.

    1996-05-01

    This Lawrence Berkeley National Laboratory Radiological Control Manual (LBNL RCM) has been prepared to provide guidance for site-specific additions, supplements and interpretation of the DOE Radiological Control Manual. The guidance provided in this manual is one methodology to implement the requirements given in Title 10 Code of Federal Regulations Part 835 (10 CFR 835) and the DOE Radiological Control Manual. Information given in this manual is also intended to provide demonstration of compliance to specific requirements in 10 CFR 835. The LBNL RCM (Publication 3113) and LBNL Health and Safety Manual Publication-3000 form the technical basis for the LBNL RPPmore » and will be revised as necessary to ensure that current requirements from Rules and Orders are represented. The LBNL RCM will form the standard for excellence in the implementation of the LBNL RPP.« less

  6. Influence of Manual Labor at Work on Muscular Fitness and Its Relationship With Work Performance.

    PubMed

    Ryan, Eric D; Thompson, Brennan J; Sobolewski, Eric J

    2016-10-01

    The present study examined the influence of workplace manual labor on measures of muscular fitness, with a secondary aim to investigate the relationship between muscular fitness and work performance in blue-collar (BC) workers. Leg extension isokinetic strength at slow and fast velocities, hamstring and hip-flexor flexibility, and low back muscular endurance were examined in young and older BC workers and white-collar (WC) controls, while work performance was examined in the BC cohort. There were no differences in muscular fitness variables between BC and WC groups; however, the older men had lower low back muscular endurance (-43.0%) and strength at slow (-9.4%) and fast (-12.7%) velocities. Work performance was associated with strength at fast velocities (r = 0.633) in the older BC workers. Leg strength may influence work performance, with higher velocities becoming more important in older workers.

  7. 3T MR-guided in-bore transperineal prostate biopsy: A comparison of robotic and manual needle-guidance templates.

    PubMed

    Tilak, Gaurie; Tuncali, Kemal; Song, Sang-Eun; Tokuda, Junichi; Olubiyi, Olutayo; Fennessy, Fiona; Fedorov, Andriy; Penzkofer, Tobias; Tempany, Clare; Hata, Nobuhiko

    2015-07-01

    To demonstrate the utility of a robotic needle-guidance template device as compared to a manual template for in-bore 3T transperineal magnetic resonance imaging (MRI)-guided prostate biopsy. This two-arm mixed retrospective-prospective study included 99 cases of targeted transperineal prostate biopsies. The biopsy needles were aimed at suspicious foci noted on multiparametric 3T MRI using manual template (historical control) as compared with a robotic template. The following data were obtained: the accuracy of average and closest needle placement to the focus, histologic yield, percentage of cancer volume in positive core samples, complication rate, and time to complete the procedure. In all, 56 cases were performed using the manual template and 43 cases were performed using the robotic template. The mean accuracy of the best needle placement attempt was higher in the robotic group (2.39 mm) than the manual group (3.71 mm, P < 0.027). The mean core procedure time was shorter in the robotic (90.82 min) than the manual group (100.63 min, P < 0.030). Percentage of cancer volume in positive core samples was higher in the robotic group (P < 0.001). Cancer yields and complication rates were not statistically different between the two subgroups (P = 0.557 and P = 0.172, respectively). The robotic needle-guidance template helps accurate placement of biopsy needles in MRI-guided core biopsy of prostate cancer. © 2014 Wiley Periodicals, Inc.

  8. Biosafety Manual

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    King, Bruce W.

    2010-05-18

    Work with or potential exposure to biological materials in the course of performing research or other work activities at Lawrence Berkeley National Laboratory (LBNL) must be conducted in a safe, ethical, environmentally sound, and compliant manner. Work must be conducted in accordance with established biosafety standards, the principles and functions of Integrated Safety Management (ISM), this Biosafety Manual, Chapter 26 (Biosafety) of the Health and Safety Manual (PUB-3000), and applicable standards and LBNL policies. The purpose of the Biosafety Program is to protect workers, the public, agriculture, and the environment from exposure to biological agents or materials that may causemore » disease or other detrimental effects in humans, animals, or plants. This manual provides workers; line management; Environment, Health, and Safety (EH&S) Division staff; Institutional Biosafety Committee (IBC) members; and others with a comprehensive overview of biosafety principles, requirements from biosafety standards, and measures needed to control biological risks in work activities and facilities at LBNL.« less

  9. Agricultural Electricity. Electric Controls. Student Manual. Report No. 820/20.

    ERIC Educational Resources Information Center

    Benson, Robert T.

    Addressed to the student, this manual presents terms, abbreviations, and symbols used in discussing manual or automatic control of the flow of electric current. Diagrams accompany discussion of the following types of control devices and principles of operation: Heat sensitive controls (thermostats, thermal relays), light sensitive controls…

  10. Development of the Coordination between Posture and Manual Control

    ERIC Educational Resources Information Center

    Haddad, Jeffrey M.; Claxton, Laura J.; Keen, Rachel; Berthier, Neil E.; Riccio, Gary E.; Hamill, Joseph; Van Emmerik, Richard E. A.

    2012-01-01

    Studies have suggested that proper postural control is essential for the development of reaching. However, little research has examined the development of the coordination between posture and manual control throughout childhood. We investigated the coordination between posture and manual control in children (7- and 10-year-olds) and adults during…

  11. The paradox of sham therapy and placebo effect in osteopathy

    PubMed Central

    Cerritelli, Francesco; Verzella, Marco; Cicchitti, Luca; D’Alessandro, Giandomenico; Vanacore, Nicola

    2016-01-01

    Abstract Background: Placebo, defined as “false treatment,” is a common gold-standard method to assess the validity of a therapy both in pharmacological trials and manual medicine research where placebo is also referred to as “sham therapy.” In the medical literature, guidelines have been proposed on how to conduct robust placebo-controlled trials, but mainly in a drug-based scenario. In contrast, there are not precise guidelines on how to conduct a placebo-controlled in manual medicine trials (particularly osteopathy). The aim of the present systematic review was to report how and what type of sham methods, dosage, operator characteristics, and patient types were used in osteopathic clinical trials and, eventually, assess sham clinical effectiveness. Methods: A systematic Cochrane-based review was conducted by analyzing the osteopathic trials that used both manual and nonmanual placebo control. Searches were conducted on 8 databases from journal inception to December 2015 using a pragmatic literature search approach. Two independent reviewers conducted the study selection and data extraction for each study. The risk of bias was evaluated according to the Cochrane methods. Results: A total of 64 studies were eligible for analysis collecting a total of 5024 participants. More than half (43 studies) used a manual placebo; 9 studies used a nonmanual placebo; and 12 studies used both manual and nonmanual placebo. Data showed lack of reporting sham therapy information across studies. Risk of bias analysis demonstrated a high risk of bias for allocation, blinding of personnel and participants, selective, and other bias. To explore the clinical effects of sham therapies used, a quantitative analysis was planned. However, due to the high heterogeneity of sham approaches used no further analyses were performed. Conclusion: High heterogeneity regarding placebo used between studies, lack of reporting information on placebo methods and within-study variability between sham and real treatment procedures suggest prudence in reading and interpreting study findings in manual osteopathic randomized controlled trials (RCTs). Efforts must be made to promote guidelines to design the most reliable placebo for manual RCTs as a means of increasing the internal validity and improve external validity of findings. PMID:27583913

  12. The paradox of sham therapy and placebo effect in osteopathy: A systematic review.

    PubMed

    Cerritelli, Francesco; Verzella, Marco; Cicchitti, Luca; D'Alessandro, Giandomenico; Vanacore, Nicola

    2016-08-01

    Placebo, defined as "false treatment," is a common gold-standard method to assess the validity of a therapy both in pharmacological trials and manual medicine research where placebo is also referred to as "sham therapy." In the medical literature, guidelines have been proposed on how to conduct robust placebo-controlled trials, but mainly in a drug-based scenario. In contrast, there are not precise guidelines on how to conduct a placebo-controlled in manual medicine trials (particularly osteopathy). The aim of the present systematic review was to report how and what type of sham methods, dosage, operator characteristics, and patient types were used in osteopathic clinical trials and, eventually, assess sham clinical effectiveness. A systematic Cochrane-based review was conducted by analyzing the osteopathic trials that used both manual and nonmanual placebo control. Searches were conducted on 8 databases from journal inception to December 2015 using a pragmatic literature search approach. Two independent reviewers conducted the study selection and data extraction for each study. The risk of bias was evaluated according to the Cochrane methods. A total of 64 studies were eligible for analysis collecting a total of 5024 participants. More than half (43 studies) used a manual placebo; 9 studies used a nonmanual placebo; and 12 studies used both manual and nonmanual placebo. Data showed lack of reporting sham therapy information across studies. Risk of bias analysis demonstrated a high risk of bias for allocation, blinding of personnel and participants, selective, and other bias. To explore the clinical effects of sham therapies used, a quantitative analysis was planned. However, due to the high heterogeneity of sham approaches used no further analyses were performed. High heterogeneity regarding placebo used between studies, lack of reporting information on placebo methods and within-study variability between sham and real treatment procedures suggest prudence in reading and interpreting study findings in manual osteopathic randomized controlled trials (RCTs). Efforts must be made to promote guidelines to design the most reliable placebo for manual RCTs as a means of increasing the internal validity and improve external validity of findings.

  13. Human Factors Approach to Comparative Usability of Hospital Manual Defibrillators.

    PubMed

    Fidler, Richard; Johnson, Meshell

    2016-04-01

    Equipment-related issues have recently been cited as a significant contributor to the suboptimal outcomes of resuscitation management. A systematic evaluation of the human-device interface was undertaken to evaluate the intuitive nature of three different defibrillators. Devices tested were the Physio-Control LifePak 15, the Zoll R Series Plus, and the Philips MRx. A convenience sample of 73 multidisciplinary health care providers from 5 different hospitals participated in this study. All subjects' performances were evaluated without any training on the devices being studied to assess the intuitiveness of the user interface to perform the functions of delivering an Automated External Defibrillator (AED) shock, a manual defibrillation, pacing to achieve 100% capture, and synchronized cardioversion on a rhythm simulator. Times to deliver an AED shock were fastest with the Zoll, whereas the Philips had the fastest times to deliver a manual defibrillation. Subjects took the least time to attain 100% capture for pacing with the Physio-Control device. No differences in performance times were seen with synchronized cardioversion among the devices. Human factors issues uncovered during this study included a preference for knobs over soft keys and a desire for clarity in control panel design. This study demonstrated no clearly superior defibrillator, as each of the models exhibited strengths in different areas. When asked their defibrillator preference, 67% of subjects chose the Philips. This comparison of user interfaces of defibrillators in simulated situations allows the assessment of usability that can provide manufacturers and educators with feedback about defibrillator implementation for these critical care devices. Published by Elsevier Ireland Ltd.

  14. 14 CFR 25.1587 - Performance information.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... 14 Aeronautics and Space 1 2010-01-01 2010-01-01 false Performance information. 25.1587 Section 25... Manual § 25.1587 Performance information. (a) Each Airplane Flight Manual must contain information to... Manual must contain the performance information computed under the applicable provisions of this part...

  15. 14 CFR 25.1587 - Performance information.

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... 14 Aeronautics and Space 1 2012-01-01 2012-01-01 false Performance information. 25.1587 Section 25... Manual § 25.1587 Performance information. (a) Each Airplane Flight Manual must contain information to... Manual must contain the performance information computed under the applicable provisions of this part...

  16. 14 CFR 25.1587 - Performance information.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... 14 Aeronautics and Space 1 2011-01-01 2011-01-01 false Performance information. 25.1587 Section 25... Manual § 25.1587 Performance information. (a) Each Airplane Flight Manual must contain information to... Manual must contain the performance information computed under the applicable provisions of this part...

  17. 14 CFR 25.1587 - Performance information.

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... 14 Aeronautics and Space 1 2013-01-01 2013-01-01 false Performance information. 25.1587 Section 25... Manual § 25.1587 Performance information. (a) Each Airplane Flight Manual must contain information to... Manual must contain the performance information computed under the applicable provisions of this part...

  18. OT calibration and service maintenance manual.

    DOT National Transportation Integrated Search

    2012-01-01

    The machine conditions, as well as the values at the calibration and control parameters, may determine the quality of each test results obtained. In order to keep consistency and accuracy, the conditions, performance and measurements of an OT must be...

  19. A Manual Control Test for the Detection and Deterrence of Impaired Drivers

    NASA Technical Reports Server (NTRS)

    Stein, A. C.; Allen, R. W.; Jex, H. R.

    1984-01-01

    A brief manual control test and a decision strategy were developed, laboratory tested, and field validated which provide a means for detecting human operator impairment from alcohol or other drugs. The test requires the operator to stabilize progressively unstable controlled element dynamics. Control theory and experimental data verify that the human operator's control ability on this task is constrained by basic cybernetic characteristics, and that task performance is reliably affected by impairment effects on these characteristics. Assessment of human operator control ability is determined by a statistically based decision strategy. The operator is allowed several chances to exceed a preset pass criterion. Procedures are described for setting the pass criterion based on individual ability and a desired unimpaired failure rate. These procedures were field tested with apparatus installed in automobiles that were designed to discourage drunk drivers from operating their vehicles. This test program demonstrated that the control task and detection strategy could be applied in a practical setting to screen human operators for impairment in their basic cybernetic skills.

  20. Age-Related Interference between the Selection of Input-Output Modality Mappings and Postural Control—a Pilot Study

    PubMed Central

    Stelzel, Christine; Schauenburg, Gesche; Rapp, Michael A.; Heinzel, Stephan; Granacher, Urs

    2017-01-01

    Age-related decline in executive functions and postural control due to degenerative processes in the central nervous system have been related to increased fall-risk in old age. Many studies have shown cognitive-postural dual-task interference in old adults, but research on the role of specific executive functions in this context has just begun. In this study, we addressed the question whether postural control is impaired depending on the coordination of concurrent response-selection processes related to the compatibility of input and output modality mappings as compared to impairments related to working-memory load in the comparison of cognitive dual and single tasks. Specifically, we measured total center of pressure (CoP) displacements in healthy female participants aged 19–30 and 66–84 years while they performed different versions of a spatial one-back working memory task during semi-tandem stance on an unstable surface (i.e., balance pad) while standing on a force plate. The specific working-memory tasks comprised: (i) modality compatible single tasks (i.e., visual-manual or auditory-vocal tasks), (ii) modality compatible dual tasks (i.e., visual-manual and auditory-vocal tasks), (iii) modality incompatible single tasks (i.e., visual-vocal or auditory-manual tasks), and (iv) modality incompatible dual tasks (i.e., visual-vocal and auditory-manual tasks). In addition, participants performed the same tasks while sitting. As expected from previous research, old adults showed generally impaired performance under high working-memory load (i.e., dual vs. single one-back task). In addition, modality compatibility affected one-back performance in dual-task but not in single-task conditions with strikingly pronounced impairments in old adults. Notably, the modality incompatible dual task also resulted in a selective increase in total CoP displacements compared to the modality compatible dual task in the old but not in the young participants. These results suggest that in addition to effects of working-memory load, processes related to simultaneously overcoming special linkages between input- and output modalities interfere with postural control in old but not in young female adults. Our preliminary data provide further evidence for the involvement of cognitive control processes in postural tasks. PMID:28484411

  1. Effects of False Tilt Cues on the Training of Manual Roll Control Skills

    NASA Technical Reports Server (NTRS)

    Zaal, Peter M. T.; Popovici, Alexandru; Zavala, Melinda A.

    2015-01-01

    This paper describes a transfer-of-training study performed in the NASA Ames Vertica lMotion Simulator. The purpose of the study was to investigate the effect of false tilt cues on training and transfer of training of manual roll control skills. Of specific interest were the skills needed to control unstable roll dynamics of a mid-size transport aircraft close to the stall point. Nineteen general aviation pilots trained on a roll control task with one of three motion conditions: no motion, roll motion only, or reduced coordinated roll motion. All pilots transferred to full coordinated roll motion in the transfer session. A novel multimodal pilot model identification technique was successfully applied to characterize how pilots' use of visual and motion cues changed over the course of training and after transfer. Pilots who trained with uncoordinated roll motion had significantly higher performance during training and after transfer, even though they experienced the false tilt cues. Furthermore, pilot control behavior significantly changed during the two sessions, as indicated by increasing visual and motion gains, and decreasing lead time constants. Pilots training without motion showed higher learning rates after transfer to the full coordinated roll motion case.

  2. Haptic Guidance Improves the Visuo-Manual Tracking of Trajectories

    PubMed Central

    Bluteau, Jérémy; Coquillart, Sabine; Payan, Yohan; Gentaz, Edouard

    2008-01-01

    Background Learning to perform new movements is usually achieved by following visual demonstrations. Haptic guidance by a force feedback device is a recent and original technology which provides additional proprioceptive cues during visuo-motor learning tasks. The effects of two types of haptic guidances-control in position (HGP) or in force (HGF)–on visuo-manual tracking (“following”) of trajectories are still under debate. Methodology/Principals Findings Three training techniques of haptic guidance (HGP, HGF or control condition, NHG, without haptic guidance) were evaluated in two experiments. Movements produced by adults were assessed in terms of shapes (dynamic time warping) and kinematics criteria (number of velocity peaks and mean velocity) before and after the training sessions. Trajectories consisted of two Arabic and two Japanese-inspired letters in Experiment 1 and ellipses in Experiment 2. We observed that the use of HGF globally improves the fluency of the visuo-manual tracking of trajectories while no significant improvement was found for HGP or NHG. Conclusion/Significance These results show that the addition of haptic information, probably encoded in force coordinates, play a crucial role on the visuo-manual tracking of new trajectories. PMID:18335049

  3. Wheelchair skills training to improve confidence with using a manual wheelchair among older adults: A pilot study

    PubMed Central

    Sakakibara, Brodie M.; Miller, William C.; Souza, Melanie; Nikolova, Viara; Best, Krista L.

    2014-01-01

    Objectives To examine the effects of wheelchair skills training on confidence in older adults who are inexperienced with using a wheelchair. Design Parallel group, single blind randomized controlled trial Setting Vancouver, Canada Participants Participants (N=20) who were community-living older adults at least 65 years old (mean = 70 years), 50% female, and who had no prior experience using a wheelchair were randomly allocated to an intervention (n=10) or control (n=10) group. Intervention The intervention group received two 1-hour training sessions that followed the Wheelchair Skills Training Program (WSTP) protocol. The control group received a single socialization contact. Main Outcome Measure The Wheelchair Use Confidence Scale-Manual (WheelCon-M) was used to evaluate confidence with using a manual wheelchair. The WheelCon-M is a self-report questionnaire comprised of 65 items in 6 conceptual areas. Results A 1-way between groups analysis of covariance revealed a significant difference in post-intervention WheelCon-M scores between the intervention and control groups [F(1,17) = 10.9, p = 0.004] after controlling for baseline WheelCon-M scores. A large effect size was also observed (partial eta squared = 0.39). Secondary analyses revealed the WSTP had greater effects on confidence in areas related to maneuvering around the physical environment, knowledge and problem solving, advocacy, and managing emotions, than in areas related to performing activities and behaving in social situations. Conclusion Two 1-hour WSTP sessions improves confidence with using a manual wheelchair among older adults, inexperienced with using a wheelchair. PMID:23385110

  4. Comparison of manual & automated analysis methods for corneal endothelial cell density measurements by specular microscopy.

    PubMed

    Huang, Jianyan; Maram, Jyotsna; Tepelus, Tudor C; Modak, Cristina; Marion, Ken; Sadda, SriniVas R; Chopra, Vikas; Lee, Olivia L

    2017-08-07

    To determine the reliability of corneal endothelial cell density (ECD) obtained by automated specular microscopy versus that of validated manual methods and factors that predict such reliability. Sharp central images from 94 control and 106 glaucomatous eyes were captured with Konan specular microscope NSP-9900. All images were analyzed by trained graders using Konan CellChek Software, employing the fully- and semi-automated methods as well as Center Method. Images with low cell count (input cells number <100) and/or guttata were compared with the Center and Flex-Center Methods. ECDs were compared and absolute error was used to assess variation. The effect on ECD of age, cell count, cell size, and cell size variation was evaluated. No significant difference was observed between the Center and Flex-Center Methods in corneas with guttata (p=0.48) or low ECD (p=0.11). No difference (p=0.32) was observed in ECD of normal controls <40 yrs old between the fully-automated method and manual Center Method. However, in older controls and glaucomatous eyes, ECD was overestimated by the fully-automated method (p=0.034) and semi-automated method (p=0.025) as compared to manual method. Our findings show that automated analysis significantly overestimates ECD in the eyes with high polymegathism and/or large cell size, compared to the manual method. Therefore, we discourage reliance upon the fully-automated method alone to perform specular microscopy analysis, particularly if an accurate ECD value is imperative. Copyright © 2017. Published by Elsevier España, S.L.U.

  5. Final-Approach Spacing Aids (FASA) evaluation for terminal-area, time-based air traffic control

    NASA Technical Reports Server (NTRS)

    Credeur, Leonard; Capron, William R.; Lohr, Gary W.; Crawford, Daniel J.; Tang, Dershuen A.; Rodgers, William G., Jr.

    1993-01-01

    A jointly funded (NASA/FAA) real-time simulation study was conducted at NASA Langley Research Center to gather comparative performance data among three candidate final-approach spacing aid (FASA) display formats. Several objective measures of controller performance and their display eye-scan behavior as well as subjective workload and rating questionnaires were used. For each of two representative pattern-speed procedures (a 170-knot procedure and a 210-knot procedure with speed control aiding), data were gathered, via twelve FAA controllers, using four final-controller display format conditions (manual/ARTS 3, graphic marker, DICE countdown, and centerline slot marker). Measured runway separations were more precise with both the graphic marker and DICE countdown formats than with the centerline slot marker and both (graphic and DICE) improved precision relative to the manual/ARTS 3 format. For three separate rating criteria, the subject controllers ranked the FASA formats in the same order: graphic marker, DICE countdown, and centerline slot marker. The increased precision measured with the 210-knot pattern-speed procedure may indicate the potential for the application of speed-control aiding where higher pattern speeds are practical after the base-to-final turn. Also presented are key FASA issues, a rationale for the formats selected for testing, and their description.

  6. Transfer of Training from Predictor to Conventional Displays. Interim Report.

    ERIC Educational Resources Information Center

    Wulfeck, J. W.

    Use of a predictor display has been shown to virtually transform the difficulty of a variety of complex, manual control pursuit tracking tasks to the level of those having relatively simple control requirements. With 15-minutes practice, naive operators are able to perform some complex tasks with a predictor display at accuracy levels previously…

  7. Sensory perception. [role of human vestibular system in dynamic space perception and manual vehicle control

    NASA Technical Reports Server (NTRS)

    1974-01-01

    The effect of motion on the ability of men to perform a variety of control actions was investigated. Special attention was given to experimental and analytical studies of the dynamic characteristics of the otoliths and semicircular canals using a two axis angular motion simulator and a one axis linear motion simulator.

  8. 14 CFR 27.1587 - Performance information.

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... 14 Aeronautics and Space 1 2012-01-01 2012-01-01 false Performance information. 27.1587 Section 27... Manual and Approved Manual Material § 27.1587 Performance information. (a) The Rotorcraft Flight Manual... performance information is provided and at which the rotorcraft cannot land and take off safely with the...

  9. 14 CFR 27.1587 - Performance information.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... 14 Aeronautics and Space 1 2010-01-01 2010-01-01 false Performance information. 27.1587 Section 27... Manual and Approved Manual Material § 27.1587 Performance information. (a) The Rotorcraft Flight Manual... performance information is provided and at which the rotorcraft cannot land and take off safely with the...

  10. 14 CFR 27.1587 - Performance information.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... 14 Aeronautics and Space 1 2011-01-01 2011-01-01 false Performance information. 27.1587 Section 27... Manual and Approved Manual Material § 27.1587 Performance information. (a) The Rotorcraft Flight Manual... performance information is provided and at which the rotorcraft cannot land and take off safely with the...

  11. 14 CFR 27.1587 - Performance information.

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... 14 Aeronautics and Space 1 2013-01-01 2013-01-01 false Performance information. 27.1587 Section 27... Manual and Approved Manual Material § 27.1587 Performance information. (a) The Rotorcraft Flight Manual... performance information is provided and at which the rotorcraft cannot land and take off safely with the...

  12. Automation in future air traffic management: effects of decision aid reliability on controller performance and mental workload.

    PubMed

    Metzger, Ulla; Parasuraman, Raja

    2005-01-01

    Future air traffic management concepts envisage shared decision-making responsibilities between controllers and pilots, necessitating that controllers be supported by automated decision aids. Even as automation tools are being introduced, however, their impact on the air traffic controller is not well understood. The present experiments examined the effects of an aircraft-to-aircraft conflict decision aid on performance and mental workload of experienced, full-performance level controllers in a simulated Free Flight environment. Performance was examined with both reliable (Experiment 1) and inaccurate automation (Experiment 2). The aid improved controller performance and reduced mental workload when it functioned reliably. However, detection of a particular conflict was better under manual conditions than under automated conditions when the automation was imperfect. Potential or actual applications of the results include the design of automation and procedures for future air traffic control systems.

  13. 78 FR 39285 - Information Collection Being Reviewed by the Federal Communications Commission Under Delegated...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-07-01

    .... SUPPLEMENTARY INFORMATION: OMB Control Number: 3060-0384. Title: Sections 64.901, 64.904 and 64.905, Auditor's... allocation manual is to either have an attest engagement performed by an independent auditor every two years, covering the prior two year period, or have a financial audit performed by an independent auditor...

  14. Digital Troposcatter Performance Model

    DTIC Science & Technology

    1983-12-01

    Dist Speia DIIBUTON STATEMR AO Approved tot public relemg ** - DistributionUnlimited __________ Communications. Control and Information Systems ...for digital troposcatter communication system design is described. Propagation and modem performance *are modeled. These include Path Loss and RSL...designing digital troposcatter systems . A User’s Manual Report discusses the use of the computer program TROPO. The description of the structure and logical

  15. Kinematical analysis of handwriting movements in depressed patients.

    PubMed

    Mergl, R; Juckel, G; Rihl, J; Henkel, V; Karner, M; Tigges, P; Schröter, A; Hegerl, U

    2004-05-01

    Motor disturbances are a relevant aspect of depression. Kinematical analysis of movements can be applied to explore which type of motor dysfunction is associated with depression. We hypothesized that depressed patients draw and write significantly slower than controls and that motor disturbances become more pronounced under bi-manual demands. We examined 37 depressed patients and 37 healthy controls using a digitizing graphic tablet and subsequent kinematical analysis of handwriting and rapid drawing movements. Depressed patients performed drawing with significantly less regular velocity than controls (P < 0.001), but normal velocity. Motor differences between patients and controls did not increase under bi-manual demands. Handwriting of patients was abnormally slow (P = 0.04). Irregular patterns of velocity peaks in depressed patients point to basal ganglia dysfunction and/or deficient activity of the sensorimotor cortex and the supplementary motor area as a possible substrate of hand-motor disturbances in depression.

  16. Effectiveness of a fine motor skills rehabilitation program on upper limb disability, manual dexterity, pinch strength, range of fingers motion, performance in activities of daily living, functional independency, and general self-efficacy in hand osteoarthritis: A randomized clinical trial.

    PubMed

    Pérez-Mármol, Jose Manuel; García-Ríos, Ma Carmen; Ortega-Valdivieso, María Azucena; Cano-Deltell, Enrique Elías; Peralta-Ramírez, María Isabel; Ickmans, Kelly; Aguilar-Ferrándiz, María Encarnación

    A randomized clinical trial. Rehabilitation treatments for improving fine motor skills (FMS) in hand osteoarthritis (HOA) have not been well explored yet. To assess the effectiveness of a rehabilitation program on upper limb disability, independence of activities of daily living (ADLs), fine motor abilities, functional independency, and general self-efficacy in older adults with HOA. About 45 adults (74-86 years) with HOA were assigned to an experimental group for completing an FMS intervention or a control group receiving conventional occupational therapy. Both interventions were performed 3 times/wk, 45 minutes each session, during 8 weeks. Upper limb disability, performance in ADLs, pinch strength, manual dexterity, range of fingers motion, functional independency, and general self-efficacy were assessed at baseline, immediately after treatment, and after 2 months of follow-up. FMS group showed significant improvements with a small effect size on manual dexterity (P ≤ .034; d ≥ 0.48) and a moderate-high effect on range of index (P ≤ .018; d ≥ 0.58) and thumb (P ≤ .027; d ≥ 0.39) motion. The control group showed a significant worse range of motion over time in some joints at the index (P ≤ .037; d ≥ 0.36) finger and thumb (P ≤ .017; d ≥ 0.55). A rehabilitation intervention for FMS may improve manual dexterity and range of fingers motion in HOA, but its effects on upper limb disability, performance in ADLs, pinch strength, functionality, and self-efficacy remain uncertain. Specific interventions of the hand are needed to prevent a worsening in range of finger motion. 1b. Copyright © 2016 Hanley & Belfus. Published by Elsevier Inc. All rights reserved.

  17. Procedural errors in air traffic control: effects of traffic density, expertise, and automation.

    PubMed

    Di Nocera, Francesco; Fabrizi, Roberto; Terenzi, Michela; Ferlazzo, Fabio

    2006-06-01

    Air traffic management requires operators to frequently shift between multiple tasks and/or goals with different levels of accomplishment. Procedural errors can occur when a controller accomplishes one of the tasks before the entire operation has been completed. The present study had two goals: first, to verify the occurrence of post-completion errors in air traffic control (ATC) tasks; and second, to assess effects on performance of medium term conflict detection (MTCD) tools. There were 18 military controllers who performed a simulated ATC task with and without automation support (MTCD vs. manual) in high and low air traffic density conditions. During the task, which consisted of managing several simulated flights in an enroute ATC scenario, a trace suddenly disappeared "after" the operator took the aircraft in charge, "during" the management of the trace, or "before" the pilot's first contact. In the manual condition, only the fault type "during" was found to be significantly different from the other two. On the contrary, when in the MTCD condition, the fault type "after" generated significantly less errors than the fault type "before." Additionally, automation was found to affect performance of junior controllers, whereas seniors' performance was not affected. Procedural errors can happen in ATC, but automation can mitigate this effect. Lack of benefits for the "before" fault type may be due to the fact that operators extend their reliance to a part of the task that is unsupported by the automated system.

  18. Hybrid water immersion simulation of manual IVA performance in weightlessness

    NASA Technical Reports Server (NTRS)

    Loats, H. L., Jr.; Mattingly, G. S.

    1971-01-01

    A description is given of the development, tests, and analysis of a manual simulator. The simulator was developed to test mass handling and translation under weightlessness conditions by a test subject. The system is composed of a hybrid simulator with a combination of water immersion and mechanical, Peter Pan, simulation. The concept operates on the equivalence principle, with the subject and the cargo remaining quasi-stationary. Movement is effected through a moving device controlled through force by the subject. Motion response is determined through computations of the inertial movement under such conditions.

  19. Identification of potential neuromotor mechanisms of manual therapy in patients with musculoskeletal disablement: rationale and description of a clinical trial.

    PubMed

    Fisher, Beth E; Davenport, Todd E; Kulig, Kornelia; Wu, Allan D

    2009-05-21

    Many health care practitioners use a variety of hands-on treatments to improve symptoms and disablement in patients with musculoskeletal pathology.Research to date indirectly suggests a potentially broad effect of manual therapy on the neuromotor processing of functional behavior within the supraspinal central nervous system (CNS) in a manner that may be independent of modification at the level of local spinal circuits. However, the effect of treatment speed, as well as the specific mechanism and locus of CNS changes, remain unclear. We developed a placebo-controlled, randomized study to test the hypothesis that manual therapy procedures directed to the talocrural joint in individuals with post-acute ankle sprain induce a change in corticospinal excitability that is relevant to improve the performance of lower extremity functional behavior. This study is designed to identify potential neuromotor changes associated with manual therapy procedures directed to the appendicular skeleton, compare the relative effect of treatment speed on potential neuromotor effects of manual therapy procedures, and determine the behavioral relevance of potential neuromotor effects of manual therapy procedures. http://www.clinicaltrials.gov identifier NCT00847769.

  20. Identification of potential neuromotor mechanisms of manual therapy in patients with musculoskeletal disablement: rationale and description of a clinical trial

    PubMed Central

    Fisher, Beth E; Davenport, Todd E; Kulig, Kornelia; Wu, Allan D

    2009-01-01

    Background Many health care practitioners use a variety of hands-on treatments to improve symptoms and disablement in patients with musculoskeletal pathology. Research to date indirectly suggests a potentially broad effect of manual therapy on the neuromotor processing of functional behavior within the supraspinal central nervous system (CNS) in a manner that may be independent of modification at the level of local spinal circuits. However, the effect of treatment speed, as well as the specific mechanism and locus of CNS changes, remain unclear. Methods/Design We developed a placebo-controlled, randomized study to test the hypothesis that manual therapy procedures directed to the talocrural joint in individuals with post-acute ankle sprain induce a change in corticospinal excitability that is relevant to improve the performance of lower extremity functional behavior. Discussion This study is designed to identify potential neuromotor changes associated with manual therapy procedures directed to the appendicular skeleton, compare the relative effect of treatment speed on potential neuromotor effects of manual therapy procedures, and determine the behavioral relevance of potential neuromotor effects of manual therapy procedures. Trial Registration identifier NCT00847769. PMID:19460169

  1. Collision avoidance system cost-benefit analysis : volume I - technical manual

    DOT National Transportation Integrated Search

    1981-09-01

    Collision-avoidance systems under development in the U.S.A., Japan and Germany were evaluated. The performance evaluation showed that the signal processing and the control law of a system were the key parameters that decided the system's capability, ...

  2. Robust, Decoupled, Flight Control Design with Rate Saturating Actuators

    NASA Technical Reports Server (NTRS)

    Snell, S. A.; Hess, R. A.

    1997-01-01

    Techniques for the design of control systems for manually controlled, high-performance aircraft must provide the following: (1) multi-input, multi-output (MIMO) solutions, (2) acceptable handling qualities including no tendencies for pilot-induced oscillations, (3) a tractable approach for compensator design, (4) performance and stability robustness in the presence of significant plant uncertainty, and (5) performance and stability robustness in the presence actuator saturation (particularly rate saturation). A design technique built upon Quantitative Feedback Theory is offered as a candidate methodology which can provide flight control systems meeting these requirements, and do so over a considerable part of the flight envelope. An example utilizing a simplified model of a supermaneuverable fighter aircraft demonstrates the proposed design methodology.

  3. Texting while driving using Google Glass™: Promising but not distraction-free.

    PubMed

    He, Jibo; Choi, William; McCarley, Jason S; Chaparro, Barbara S; Wang, Chun

    2015-08-01

    Texting while driving is risky but common. This study evaluated how texting using a Head-Mounted Display, Google Glass, impacts driving performance. Experienced drivers performed a classic car-following task while using three different interfaces to text: fully manual interaction with a head-down smartphone, vocal interaction with a smartphone, and vocal interaction with Google Glass. Fully manual interaction produced worse driving performance than either of the other interaction methods, leading to more lane excursions and variable vehicle control, and higher workload. Compared to texting vocally with a smartphone, texting using Google Glass produced fewer lane excursions, more braking responses, and lower workload. All forms of texting impaired driving performance compared to undistracted driving. These results imply that the use of Google Glass for texting impairs driving, but its Head-Mounted Display configuration and speech recognition technology may be safer than texting using a smartphone. Copyright © 2015 Elsevier Ltd. All rights reserved.

  4. Safe, Effective Use of Pesticides, A Manual for Commercial Applicators: Aquatic Pest Control.

    ERIC Educational Resources Information Center

    Extension Service (USDA), Washington, DC.

    This manual is intended to assist pesticide applicators in the area of aquatic pest control meet the requirements of the Michigan Department of Agriculture for certification. The Environmental Protection Agency (EPA) Aquatic Pest Control Guide served as a basis for this manual. The six sections presented describe: (1) Aquatic pest control; (2)…

  5. 77 FR 28455 - National Standards for Traffic Control Devices; the Manual on Uniform Traffic Control Devices for...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-05-14

    ... Options for design and applications of traffic control devices, this Manual should not be considered a... application of traffic control devices, as well as in the location and design of roads and streets that the..., while this Manual provides Standards, Guidance, and Options for design and applications of traffic...

  6. Thoracic manual therapy is not more effective than placebo thoracic manual therapy in patients with shoulder dysfunctions: A systematic review with meta-analysis.

    PubMed

    Bizzarri, Paolo; Buzzatti, Luca; Cattrysse, Erik; Scafoglieri, Aldo

    2018-02-01

    Manual treatments targeting different regions (shoulder, cervical spine, thoracic spine, ribs) have been studied to deal with patients complaining of shoulder pain. Thoracic manual treatments seem able to produce beneficial effects on this group of patients. However, it is not clear whether the patient improvement is a consequence of thoracic manual therapy or a placebo effect. To compare the efficacy of thoracic manual therapy and placebo thoracic manual treatment for patients with shoulder dysfunction. Electronic databases (MEDLINE, CENTRAL, PEDro, CINAHL, WoS, EMBASE, ERIC) were searched through November 2016. Randomized Controlled Trials assessing pain, mobility and function were selected. The Cochrane bias estimation tool was applied. Outcome results were either extracted or computed from raw data. Meta-analysis was performed for outcomes with low heterogeneity. Four studies were included in the review. The methodology of the included studies was generally good except for one study that was rated as high risk of bias. Meta-analysis showed no significant effect for "pain at present" (SMD -0.02; 95% CI: -0.35, 0.32) and "pain during movement" (SMD -0.12; 95% CI: -0.45, 0.21). There is very low to low quality of evidence that a single session of thoracic manual therapy is not more effective than a single session of placebo thoracic manual therapy in patients with shoulder dysfunction at immediate post-treatment. Copyright © 2017 Elsevier Ltd. All rights reserved.

  7. Manual Khalifa Therapy Improves Functional and Morphological Outcome of Patients with Anterior Cruciate Ligament Rupture in the Knee: A Randomized Controlled Trial

    PubMed Central

    Kastner, Andreas; Wallenboeck, Engelbert; Pehn, Robert; Schneider, Frank; Groell, Reinhard; Szolar, Dieter; Walach, Harald; Sandner-Kiesling, Andreas

    2014-01-01

    Rupture of the anterior cruciate ligament (ACL) is a high incidence injury usually treated surgically. According to common knowledge, it does not heal spontaneously, although some claim the opposite. Regeneration therapy by Khalifa was developed for injuries of the musculoskeletal system by using specific pressure to the skin. This randomized, controlled, observer-blinded, multicentre study was performed to validate this assumption. Thirty patients with complete ACL rupture, magnetic resonance imaging (MRI) verified, were included. Study examinations (e.g., international knee documentation committee (IKDC) score) were performed at inclusion (t 0). Patients were randomized to receive either standardised physiotherapy (ST) or additionally 1 hour of Khalifa therapy at the first session (STK). Twenty-four hours later, study examinations were performed again (t 1). Three months later control MRI and follow-up examinations were performed (t 2). Initial status was comparable between both groups. There was a highly significant difference of mean IKDC score results at t 1 and t 2. After 3 months, 47% of the STK patients, but no ST patient, demonstrated an end-to-end homogeneous ACL in MRI. Clinical and physical examinations were significantly different in t 1 and t 2. ACL healing can be improved with manual therapy. Physical activity can be performed without pain and nearly normal range of motion after one treatment of specific pressure. PMID:24600477

  8. Short Haul Civil Tiltrotor Study in MIDAS: Auto versus Manual Nacelle Procedures for Commanded Go-Around

    NASA Technical Reports Server (NTRS)

    Atencio, Adolph, Jr.; Banda, Carolyn

    1998-01-01

    Tiltrotor aircraft combine the speed and range of a turboprop performance with the ability to take off and land in a vertical mode like a helicopter. These aircraft will transport passengers from city center to city center and from satellite airports to major hub airports to make connections to long range travel. The Short Haul Civil Tiltrotor (SH(CT)) being studied by NASA is a concept 40 passenger civil tiltrotor (CTR) transport. The Man-machine Integration Design and Analysis System (MIDAS) was used to evaluate human performance in terms of crew procedures and pilot workload for a simulated 40 passenger Civil Tiltrotor Transport on a steep approach to a vertiport. The scenario for the simulation was a normal approach to the vertiport that is interrupted by a commanded go-around at the landing decision point. The simulation contrasted an automated discrete nacelle mode control with a fully manual nacelle control mode for the go-around. The MIDAS simulation showed that the pilot task loading during approach and for the commanded go-around is high and that pilot workload is near capacity throughout. The go-around in manual nacelle mode was most demanding, resulting in additional time requirements to complete necessary tasks.

  9. 46 CFR 62.25-10 - Manual alternate control systems.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 46 Shipping 2 2010-10-01 2010-10-01 false Manual alternate control systems. 62.25-10 Section 62.25-10 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) MARINE ENGINEERING VITAL SYSTEM AUTOMATION General Requirements for All Automated Vital Systems § 62.25-10 Manual alternate control systems...

  10. Time series modeling of human operator dynamics in manual control tasks

    NASA Technical Reports Server (NTRS)

    Biezad, D. J.; Schmidt, D. K.

    1984-01-01

    A time-series technique is presented for identifying the dynamic characteristics of the human operator in manual control tasks from relatively short records of experimental data. Control of system excitation signals used in the identification is not required. The approach is a multi-channel identification technique for modeling multi-input/multi-output situations. The method presented includes statistical tests for validity, is designed for digital computation, and yields estimates for the frequency responses of the human operator. A comprehensive relative power analysis may also be performed for validated models. This method is applied to several sets of experimental data; the results are discussed and shown to compare favorably with previous research findings. New results are also presented for a multi-input task that has not been previously modeled to demonstrate the strengths of the method.

  11. Time Series Modeling of Human Operator Dynamics in Manual Control Tasks

    NASA Technical Reports Server (NTRS)

    Biezad, D. J.; Schmidt, D. K.

    1984-01-01

    A time-series technique is presented for identifying the dynamic characteristics of the human operator in manual control tasks from relatively short records of experimental data. Control of system excitation signals used in the identification is not required. The approach is a multi-channel identification technique for modeling multi-input/multi-output situations. The method presented includes statistical tests for validity, is designed for digital computation, and yields estimates for the frequency response of the human operator. A comprehensive relative power analysis may also be performed for validated models. This method is applied to several sets of experimental data; the results are discussed and shown to compare favorably with previous research findings. New results are also presented for a multi-input task that was previously modeled to demonstrate the strengths of the method.

  12. Advanced Communications Technology Satellite high burst rate link evaluation terminal experiment control and monitor software maintenance manual, version 1.0

    NASA Technical Reports Server (NTRS)

    Reinhart, Richard C.

    1992-01-01

    The Experiment Control and Monitor (EC&M) software was developed at NASA Lewis Research Center to support the Advanced Communications Technology Satellite (ACTS) High Burst Rate Link Evaluation Terminal (HBR-LET). The HBR-LET is an experimenter's terminal to communicate with the ACTS for various investigations by government agencies, universities, and industry. The EC&M software is one segment of the Control and Performance Monitoring (C&PM) software system of the HBR-LET. The EC&M software allows users to initialize, control, and monitor the instrumentation within the HBR-LET using a predefined sequence of commands. Besides instrument control, the C&PM software system is also responsible for computer communication between the HBR-LET and the ACTS NASA Ground Station and for uplink power control of the HBR-LET to demonstrate power augmentation during rain fade events. The EC&M Software User's Guide, Version 1.0 (NASA-CR-189160) outlines the commands required to install and operate the EC&M software. Input and output file descriptions, operator commands, and error recovery procedures are discussed in the document. The EC&M Software Maintenance Manual, Version 1.0 (NASA-CR-189161) is a programmer's guide that describes current implementation of the EC&M software from a technical perspective. An overview of the EC&M software, computer algorithms, format representation, and computer hardware configuration are included in the manual.

  13. Effect of cold conditions on manual performance while wearing petroleum industry protective clothing.

    PubMed

    Wiggen, Øystein Nordrum; Heen, Sigri; Færevik, Hilde; Reinertsen, Randi Eidsmo

    2011-01-01

    The purpose of this study was to investigate manual performance and thermal responses during low work intensity in persons wearing standard protective clothing in the petroleum industry when they were exposed to a range of temperatures (5, -5, -15 and -25℃) that are relevant to environmental conditions for petroleum industry personnel in northern regions. Twelve men participated in the study. Protective clothing was adjusted for the given cold exposure according to current practices. The subjects performed manual tests five times under each environmental condition. The manual performance test battery consisted of four different tests: tactile sensation (Semmes-Weinstein monofilaments), finger dexterity (Purdue Pegboard), hand dexterity (Complete Minnesota dexterity test) and grip strength (grip dynamometer). We found that exposure to -5℃ or colder lowered skin and body temperatures and reduced manual performance during low work intensity. In conclusion the current protective clothing at a given cold exposure is not adequate to maintain manual performance and thermal balance for petroleum workers in the high north.

  14. Control with an eye for perception: Precursors to an active psychophysics

    NASA Technical Reports Server (NTRS)

    Flach, John M.

    1991-01-01

    The perception-action cycle is viewed within the context of research in manual control. A portrait of a perception-action system is derived from the primitives of control theory in order to evaluate the promise of this perspective of what Warren and McMillan (1984) have termed 'active psychophysics'. That is, a study of human performance that does justice to the intimate coupling between perception and action.

  15. User's Manual for the Naval Interactive Data Analysis System-Climatologies (NIDAS-C), Version 2.0

    NASA Technical Reports Server (NTRS)

    Abbott, Clifton

    1996-01-01

    This technical note provides the user's manual for the NIDAS-C system developed for the naval oceanographic office. NIDAS-C operates using numerous oceanographic data categories stored in an installed version of the Naval Environmental Operational Nowcast System (NEONS), a relational database management system (rdbms) which employs the ORACLE proprietary rdbms engine. Data management, configuration, and control functions for the supporting rdbms are performed externally. NIDAS-C stores and retrieves data to/from the rdbms but exercises no direct internal control over the rdbms or its configuration. Data is also ingested into the rdbms, for use by NIDAS-C, by external data acquisition processes. The data categories employed by NIDAS-C are as follows: Bathymetry - ocean depth at

  16. Manual de Adiestramiento sobre Terapia de Rehidratacion Oral y Control de las Enfermedades Diarreicas (Oral Rehydration Therapy and the Control of Diarrheal Diseases). Training for Development. Peace Corps Information Collection & Exchange Training Manual No. T-53.

    ERIC Educational Resources Information Center

    Clark, Mari; And Others

    This Spanish-language manual was developed to train Peace Corps volunteers and other community health workers in Spanish-speaking countries in oral rehydration therapy (ORT) and the control of diarrheal diseases. Using a competency-based format, the manual contains three training modules (organized in seven sessions) that focus on interrelated…

  17. The relationship among eye movements, head movements, and manual responses in a simulated air traffic control task.

    DOT National Transportation Integrated Search

    1995-08-01

    Performance of operators in aviation systems is highly dependent on their ability to visually scan information sources, identify problematic situations, and respond appropriately. Scanning behavior has often been mentioned as a contributing factor in...

  18. A high performance two degree-of-freedom kinesthetic interface

    NASA Technical Reports Server (NTRS)

    Adelstein, Bernard D.; Rosen, Michael J.

    1991-01-01

    This summary focuses on the kinesthetic interface of a virtual environment system that was developed at the Newman Laboratory for Biomechanics and Human Rehabilitation at M.I.T. for the study of manual control in both motorically impaired and able-bodied individuals.

  19. First step in managing bulimia nervosa: controlled trial of therapeutic manual.

    PubMed Central

    Treasure, J.; Schmidt, U.; Troop, N.; Tiller, J.; Todd, G.; Keilen, M.; Dodge, E.

    1994-01-01

    OBJECTIVE--To test the short term efficacy of a self directed treatment manual for bulimia nervosa. DESIGN--Randomised controlled trial of the manual against cognitive behavioural therapy and a waiting list. SETTING--Tertiary referral centre. SUBJECTS--81 consecutive referrals presenting with bulimia nervosa or atypical bulimia nervosa. MAIN OUTCOME MEASURES--Frequency of binge eating, vomiting, and other behaviours to control weight as well as abstinence from these behaviours. RESULTS--Cognitive behavioural treatment produced a significant reduction in the frequency of binge eating, vomiting, and other behaviours to control weight. The manual significantly reduced frequency of binge eating and weight control behaviours other than vomiting, and there was no change in the group on the waiting list. Full remission was achieved in five (24%) of the group assigned to cognitive behavioural treatment, nine (22%) of the group who used the manual, and two (11%) of the group on the waiting list. CONCLUSIONS--A self directed treatment manual may be a useful first intervention in the treatment of bulimia nervosa. PMID:8142791

  20. Teaching artificial neural systems to drive: Manual training techniques for autonomous systems

    NASA Technical Reports Server (NTRS)

    Shepanski, J. F.; Macy, S. A.

    1987-01-01

    A methodology was developed for manually training autonomous control systems based on artificial neural systems (ANS). In applications where the rule set governing an expert's decisions is difficult to formulate, ANS can be used to extract rules by associating the information an expert receives with the actions taken. Properly constructed networks imitate rules of behavior that permits them to function autonomously when they are trained on the spanning set of possible situations. This training can be provided manually, either under the direct supervision of a system trainer, or indirectly using a background mode where the networks assimilates training data as the expert performs its day-to-day tasks. To demonstrate these methods, an ANS network was trained to drive a vehicle through simulated freeway traffic.

  1. Hazardous Waste Minimization Assessment: Fort Meade, MD

    DTIC Science & Technology

    1991-01-01

    Manual TSCA Toxic Substances Control Act TSDF T.xatment. Storage, and Disposal Facility USACERL U.S. Army Construction Engineering Research Laboratory...generation; and current methods of treatment, storage, and disposal, researchers conducted feasibility and economicanalyses of milnimizaion options...Bernard A. Donahue 7. PERFORMING ORGANIZATION NAME(S) ANO ADO ESS(ES) S. PERFORMING ORGANIZATION REPORT NUMBER U.S. Army Construction Engineering Research

  2. Minimizing the endophthalmitis rate following intravitreal injections using 0.25% povidone-iodine irrigation and surgical mask.

    PubMed

    Shimada, Hiroyuki; Hattori, Takayuki; Mori, Ryusaburo; Nakashizuka, Hiroyuki; Fujita, Kyoko; Yuzawa, Mitsuko

    2013-08-01

    To examine the efficacy of complying with an infection control manual for intravitreal injection of anti-vascular endothelial growth factor (VEGF) preparations in reducing the rate of endophthalmitis. We retrospectively reviewed intravitreal anti-VEGF injections conducted by vitreoretinal specialists at the outpatient injection room of a single university hospital between July 2009 and July 2012. The injections were conducted following an infection control manual established by our department. Doctors and nurses wore surgical masks, and disinfected the patient's eyelid skin with 10% povidone-iodine and then the conjunctiva with 0.25% povidone-iodine. After putting a drape on the patient's face, a lid speculum was placed. The conjunctival surface was again washed with 5 ml of 0.25% povidone-iodine. After waiting at least 30 seconds, intravitreal injection was performed through povidone-iodine. Following injection, the injection site was again washed with 5 ml of 0.25% povidone-iodine. Patients were treated with topical levofloxacin 4 times a day for 3 days before and after the injection. A total of 15,144 injections comprising 548 injections of pegaptanib sodium, 846 injections of bevacizumab, and 13,750 injections of ranibizumab were performed. During this period, no case of suspected or proven infectious endophthalmitis occurred. The endophthalmitis rate was 0 per 15,144 injections, (95% confidence interval, 0.0-0.0%). The results suggest that endophthalmitis can be reduced to a minimum by preventing normal flora of the conjunctiva and bacteria in the oral cavity from entering the vitreous. For this purpose, an infection control manual that requires nurses and doctors to wear surgical mask and drape the patient's face, irrigate the conjunctiva with 0.25% povidone-iodine and wait at least 30 seconds before performing intravitreal injection is useful.

  3. A magnetorheological haptic cue accelerator for manual transmission vehicles

    NASA Astrophysics Data System (ADS)

    Han, Young-Min; Noh, Kyung-Wook; Lee, Yang-Sub; Choi, Seung-Bok

    2010-07-01

    This paper proposes a new haptic cue function for manual transmission vehicles to achieve optimal gear shifting. This function is implemented on the accelerator pedal by utilizing a magnetorheological (MR) brake mechanism. By combining the haptic cue function with the accelerator pedal, the proposed haptic cue device can transmit the optimal moment of gear shifting for manual transmission to a driver without requiring the driver's visual attention. As a first step to achieve this goal, a MR fluid-based haptic device is devised to enable rotary motion of the accelerator pedal. Taking into account spatial limitations, the design parameters are optimally determined using finite element analysis to maximize the relative control torque. The proposed haptic cue device is then manufactured and its field-dependent torque and time response are experimentally evaluated. Then the manufactured MR haptic cue device is integrated with the accelerator pedal. A simple virtual vehicle emulating the operation of the engine of a passenger vehicle is constructed and put into communication with the haptic cue device. A feed-forward torque control algorithm for the haptic cue is formulated and control performances are experimentally evaluated and presented in the time domain.

  4. Trial Protocol: Cognitive functional therapy compared with combined manual therapy and motor control exercise for people with non-specific chronic low back pain: protocol for a randomised, controlled trial.

    PubMed

    Belache, Fabiana Terra Cunha; Souza, Cíntia Pereira de; Fernandez, Jessica; Castro, Julia; Ferreira, Paula Dos Santos; Rosa, Elizana Rodrigues de Sousa; Araújo, Nathalia Cristina Gimenez de; Reis, Felipe José Jandre; Almeida, Renato Santos de; Nogueira, Leandro Alberto Calazans; Correia, Luís Cláudio Lemos; Meziat-Filho, Ney

    2018-06-11

    Chronic low back pain is a public health problem, and there is strong evidence that it is associated with a complex interaction of biopsychosocial factors. Cognitive functional therapy is an intervention that deals with potentially modifiable multidimensional aspects of pain (eg, provocative cognitive, movement and lifestyle behaviours). There is evidence (from a single randomised, controlled trial) that cognitive functional therapy is better than combined manual therapy and motor control exercise. However, this study had significant methodological shortcomings including the failure to carry out an intention-to-treat analysis and a considerable loss of follow-up of participants. It is important to replicate this study in another domain through a randomised clinical trial with similar objectives but correcting these methodological shortcomings. To investigate the efficacy of cognitive functional therapy compared to combined manual therapy and exercise on pain and disability at 3 months in patients with chronic non-specific low back pain. Two-group, randomised, multicentre controlled trial with blinded assessors. One hundred and forty-eight participants with chronic low back pain that has persisted for >3months and no specific spinal pathology will be recruited from the school clinic of the Centro Universitário Augusto Motta and a private clinic in the city of Rio de Janeiro, Brazil. Four to 10 sessions of cognitive functional therapy. The physiotherapists who will treat the participants in the cognitive functional therapy group have previously attended 2 workshops with two different tutors of the method. Such physiotherapists have completed 106 hours of training, including workshops and patient examinations, as well as conducting a pilot study under the supervision of another physiotherapist with>3 years of clinical experience in cognitive functional therapy. Four to 10 sessions of combined manual therapy and motor control exercises. Participants in the combined manual therapy and exercise group will be treated by two physiotherapists with an average of >10years of clinical experience in manual therapy and motor control exercises, including isolated contractions of the deep abdominal muscles. The primary outcome measures will be pain intensity and disability 3 months after randomisation. Secondary outcomes will be pain and disability assessed 6 and 12 months after randomisation, and both global perceived effect and patient satisfaction at 3, 6 and 12 months after randomisation. The potential outcome mediators will be assessed at 3 and 6 months after randomisation, with brief screening questions for anxiety, social isolation, catastrophisation, depression, fear of movement, stress and sleep. Non-specific predictors and moderators will include age, gender, duration of chronic low back pain, chronicity risk (Örebro and Start Back score), number of pain areas, stressful life event, MRI scan imaging, and family history. Intention-to-treat analysis will be performed. Linear mixed models will be used to compare the mean differences in pain intensity, disability and global perceived effect between the intervention arms. The analysis of the effect of potential mediators of the treatment will be performed using the causal mediation methods described by Imai and colleagues. The baseline variables will be evaluated as predictors and moderators of treatment, including terms and interaction models. A level of statistical significance of 5% will be used in the analysis. All the analyses will be performed using RStudio. This study will investigate whether the results of the first cognitive functional therapy randomised clinical trial are reproducible. The present study will have a sample size capable of detecting clinically relevant effects of the treatment with a low risk of bias. In pragmatic terms, this clinical trial is designed to reproduce the intervention as it would be performed in clinical practice by a trained physiotherapist who works with cognitive functional therapy, which increases the relevance of this study. The combined manual therapy and exercise group comprises an intervention strategy widely used by physiotherapists to treat low back pain. As evidence of efficacy is still limited, the results of a randomised, controlled clinical trial of high methodological quality will help physiotherapists in clinical decision-making. Copyright © 2018 Australian Physiotherapy Association. Published by Elsevier B.V. All rights reserved.

  5. Comparison of the metabolic demands of dance performance using three mobility devices for a dancer with spinal cord injury and an able-bodied dancer.

    PubMed

    Mengelkoch, Larry J; Highsmith, M Jason; Morris, Merry L

    2014-09-01

    Mobility devices for dancers with physical mobility impairments have previously been limited to traditional manual or power wheelchairs. The hands-free torso-controlled mobility chair is a unique powered mobility device which allows greater freedom and expression of movement of the trunk and upper extremities. This study compared differences in energy expenditure during a standardized dance activity using three mobility devices: the hands-free torso-controlled mobility chair, a manual sports wheelchair with hand-arm control, and an electric power chair with hand-joystick control. An experienced dancer with C7 incomplete spinal cord injury (SCI) and an experienced able-bodied dancer were recruited for testing. Three measurement trials were obtained for each chair per subject. Oxygen uptake (VO2) and heart rate (HR) were measured continuously during the dance activity. Immediately following the dance activity, subjects rated perceived exertion. Significant differences (p ≤ 0.05) and similar linear patterns in VO2 and HR responses were observed between chairs for both dancers. When the hands-free mobility chair was used, the dance activity required a moderate level of energy expenditure compared to the manual sports chair or electric power chair for both dancers. Higher ratings of perceived exertion were observed in the manual chair compared to the other chairs for the dancer with SCI, but were similar between chairs for the able-bodied dancer. These results suggest that for a dancer with high-level SCI, the hands-free torso-controlled mobility chair may offer improved freedom and expressive movement possibilities and is an energy-efficient mobility device.

  6. Gait parameter control timing with dynamic manual contact or visual cues.

    PubMed

    Rabin, Ely; Shi, Peter; Werner, William

    2016-06-01

    We investigated the timing of gait parameter changes (stride length, peak toe velocity, and double-, single-support, and complete step duration) to control gait speed. Eleven healthy participants adjusted their gait speed on a treadmill to maintain a constant distance between them and a fore-aft oscillating cue (a place on a conveyor belt surface). The experimental design balanced conditions of cue modality (vision: eyes-open; manual contact: eyes-closed while touching the cue); treadmill speed (0.2, 0.4, 0.85, and 1.3 m/s); and cue motion (none, ±10 cm at 0.09, 0.11, and 0.18 Hz). Correlation analyses revealed a number of temporal relationships between gait parameters and cue speed. The results suggest that neural control ranged from feedforward to feedback. Specifically, step length preceded cue velocity during double-support duration suggesting anticipatory control. Peak toe velocity nearly coincided with its most-correlated cue velocity during single-support duration. The toe-off concluding step and double-support durations followed their most-correlated cue velocity, suggesting feedback control. Cue-tracking accuracy and cue velocity correlations with timing parameters were higher with the manual contact cue than visual cue. The cue/gait timing relationships generalized across cue modalities, albeit with greater delays of step-cycle events relative to manual contact cue velocity. We conclude that individual kinematic parameters of gait are controlled to achieve a desired velocity at different specific times during the gait cycle. The overall timing pattern of instantaneous cue velocities associated with different gait parameters is conserved across cues that afford different performance accuracies. This timing pattern may be temporally shifted to optimize control. Different cue/gait parameter latencies in our nonadaptation paradigm provide general-case evidence of the independent control of gait parameters previously demonstrated in gait adaptation paradigms. Copyright © 2016 the American Physiological Society.

  7. Closed loop ventilation mode in Intensive Care Unit: a randomized controlled clinical trial comparing the numbers of manual ventilator setting changes.

    PubMed

    Arnal, Jean-Michel; Garnero, Aude; Novotni, Dominik; Corno, Gaëlle; Donati, Stéphane-Yannis; Demory, Didier; Quintana, Gabrielle; Ducros, Laurent; Laubscher, Thomas; Durand-Gasselin, Jacques

    2018-01-01

    There is an equipoise regarding closed-loop ventilation modes and the ability to reduce workload for providers. On one hand some settings are managed by the ventilator but on another hand the automatic mode introduces new settings for the user. This randomized controlled trial compared the number of manual ventilator setting changes between a full closed loop ventilation and oxygenation mode (INTELLiVENT-ASV®) and conventional ventilation modes (volume assist control and pressure support) in Intensive Care Unit (ICU) patients. The secondary endpoints were to compare the number of arterial blood gas analysis, the sedation dose and the user acceptance. Sixty subjects with an expected duration of mechanical ventilation of at least 48 hours were randomized to be ventilated using INTELLiVENT-ASV® or conventional modes with a protocolized weaning. All manual ventilator setting changes were recorded continuously from inclusion to successful extubation or death. Arterial blood gases were performed upon decision of the clinician in charge. User acceptance score was assessed for nurses and physicians once daily using a Likert Scale. The number of manual ventilator setting changes per 24 h-period per subject was lower in INTELLiVENT-ASV® as compared to conventional ventilation group (5 [4-7] versus 10 [7-17]) manuals settings per subject per day [P<0.001]). The number of arterial blood gas analysis and the sedation doses were not significantly different between the groups. Nurses and physicians reported that INTELLiVENT-ASV® was significantly easier to use as compared to conventional ventilation (P<0.001 for nurses and P<0.01 for physicians). For mechanically ventilated ICU patients, INTELLiVENT-ASV® significantly reduces the number of manual ventilator setting changes with the same number of arterial blood gas analysis and sedation dose, and is easier to use for the caregivers as compared to conventional ventilation modes.

  8. Investigation of piloting aids for manual control of hypersonic maneuvers

    NASA Technical Reports Server (NTRS)

    Raney, David L.; Phillips, Michael R.; Person, Lee H., Jr.

    1995-01-01

    An investigation of piloting aids designed to provide precise maneuver control for an air-breathing hypersonic vehicle is described. Stringent constraints and nonintuitive high-speed flight effects associated with maneuvering in the hypersonic regime raise the question of whether manual control of such a vehicle should even be considered. The objectives of this research were to determine the extent of manual control that is desirable for a vehicle maneuvering in this regime and to identify the form of aids that must be supplied to the pilot to make such control feasible. A piloted real-time motion-based simulation of a hypersonic vehicle concept was used for this study, and the investigation focused on a single representative cruise turn maneuver. Piloting aids, which consisted of an auto throttle, throttle director, autopilot, flight director, and two head-up display configurations, were developed and evaluated. Two longitudinal control response types consisting of a rate-command/attitude-hold system and a load factor-rate/load-factor-hold system were also compared. The complete set of piloting aids, which consisted of the autothrottle, throttle director, and flight director, improved the average Cooper-Harper flying qualities ratings from 8 to 2.6, even though identical inner-loop stability and control augmentation was provided in all cases. The flight director was determined to be the most critical of these aids, and the cruise turn maneuver was unachievable to adequate performance specifications in the absence of this flight director.

  9. Comparison of CT Fluoroscopy-Guided Manual and CT-Guided Robotic Positioning System for In Vivo Needle Placements in Swine Liver

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Cornelis, F.; Takaki, H.; Laskhmanan, M.

    PurposeTo compare CT fluoroscopy-guided manual and CT-guided robotic positioning system (RPS)-assisted needle placement by experienced IR physicians to targets in swine liver.Materials and MethodsManual and RPS-assisted needle placement was performed by six experienced IR physicians to four 5 mm fiducial seeds placed in swine liver (n = 6). Placement performance was assessed for placement accuracy, procedure time, number of confirmatory scans, needle manipulations, and procedure radiation dose. Intra-modality difference in performance for each physician was assessed using paired t test. Inter-physician performance variation for each modality was analyzed using Kruskal–Wallis test.ResultsPaired comparison of manual and RPS-assisted placements to a target by the samemore » physician indicated accuracy outcomes was not statistically different (manual: 4.53 mm; RPS: 4.66 mm; p = 0.41), but manual placement resulted in higher total radiation dose (manual: 1075.77 mGy/cm; RPS: 636.4 mGy/cm; p = 0.03), required more confirmation scans (manual: 6.6; RPS: 1.6; p < 0.0001) and needle manipulations (manual: 4.6; RPS: 0.4; p < 0.0001). Procedure time for RPS was longer than manual placement (manual: 6.12 min; RPS: 9.7 min; p = 0.0003). Comparison of inter-physician performance during manual placement indicated significant differences in the time taken to complete placements (p = 0.008) and number of repositions (p = 0.04) but not in other study measures (p > 0.05). Comparison of inter-physician performance during RPS-assisted placement suggested statistically significant differences in procedure time (p = 0.02) and not in other study measures (p > 0.05).ConclusionsCT-guided RPS-assisted needle placement reduced radiation dose, number of confirmatory scans, and needle manipulations when compared to manual needle placement by experienced IR physicians, with equivalent accuracy.« less

  10. Thermal Protection System Application to Composite Cryotank Technology Demonstrator

    NASA Technical Reports Server (NTRS)

    Protz, Alison; Nettles, Mindy

    2015-01-01

    The EM41 Thermal Protection System (TPS) team contributed to the success of the Composite Cryotank Technology Demonstrator (CCTD) manufacturing by developing and implementing a low-cost solution to apply cryoinsulation foam on the exterior surface of the tank in the NASA Marshall Space Flight Center (MSFC) TPS Development Facility, Bldg. 4765. The TPS team used techniques developed for the smallscale composite cryotank to apply Stepanfoam S-180 polyurethane foam to the 5.5-meter CCTD using a manual spray process. Manual spray foam technicians utilized lifts and scaffolding to access the barrel and dome sections of the large-scale tank in the horizontal orientation. During manufacturing, the tank was then oriented vertically, allowing access to the final barrel section for manual spray foam application. The CCTD was the largest application of manual spray foam performed to date with the S-180 polyurethane foam and required the TPS team to employ best practices for process controls on the development article.

  11. Disinfection of transvaginal ultrasound probes in a clinical setting: comparative performance of automated and manual reprocessing methods.

    PubMed

    Buescher, D L; Möllers, M; Falkenberg, M K; Amler, S; Kipp, F; Burdach, J; Klockenbusch, W; Schmitz, R

    2016-05-01

    Transvaginal and intracavitary ultrasound probes are a possible source of cross-contamination with microorganisms and thus a risk to patients' health. Therefore appropriate methods for reprocessing are needed. This study was designed to compare the standard disinfection method for transvaginal ultrasound probes in Germany with an automated disinfection method in a clinical setting. This was a prospective randomized controlled clinical study of two groups. In each group, 120 microbial samples were collected from ultrasound transducers before and after disinfection with either an automated method (Trophon EPR®) or a manual method (Mikrozid Sensitive® wipes). Samples were then analyzed for microbial growth and isolates were identified to species level. Automated disinfection had a statistically significantly higher success rate of 91.4% (106/116) compared with 78.8% (89/113) for manual disinfection (P = 0.009). The risk of contamination was increased by 2.9-fold when disinfection was performed manually (odds ratio, 2.9 (95% CI, 1.3-6.3)). Before disinfection, bacterial contamination was observed on 98.8% of probes. Microbial analysis revealed 36 different species of bacteria, including skin and environmental bacteria as well as pathogenic bacteria such as Staphylococcus aureus, enterobacteriaceae and Pseudomonas spp. Considering the high number of contaminated probes and bacterial species found, disinfection of the ultrasound probe's body and handle should be performed after each use to decrease the risk of cross-contamination. This study favored automated disinfection owing to its significantly higher efficacy compared with a manual method. Copyright © 2015 ISUOG. Published by John Wiley & Sons Ltd. Copyright © 2015 ISUOG. Published by John Wiley & Sons Ltd.

  12. PSC, a Programmable Software Controller for a Multiple Bladder, Sequentially Inflatable G-Suit.

    DTIC Science & Technology

    1983-12-01

    Valves . For inflation and deflation, industrial soleniod pilot valves provide filling and dumping via a manually thrown three -poition switch...medicine with a tool for performing that research. This research concerns itself with developing a programmable valve actuation controller generic to g...Subsystem 2 - Software Controller ......... -5 %o Subsystem 3 - Cromemco D/7A S-100 Bus S y m Conversion Board ....o...... -6 Subsyst 4 Computer/ Valve

  13. The Efficacy of LUCAS in Prehospital Cardiac Arrest Scenarios: A Crossover Mannequin Study.

    PubMed

    Gyory, Robert A; Buchle, Scott E; Rodgers, David; Lubin, Jeffrey S

    2017-04-01

    High-quality cardiopulmonary resuscitation (CPR) is critical for successful cardiac arrest outcomes. Mechanical devices may improve CPR quality. We simulated a prehospital cardiac arrest, including patient transport, and compared the performance of the LUCAS™ device, a mechanical chest compression-decompression system, to manual CPR. We hypothesized that because of the movement involved in transporting the patient, LUCAS would provide chest compressions more consistent with high-quality CPR guidelines. We performed a crossover-controlled study in which a recording mannequin was placed on the second floor of a building. An emergency medical services (EMS) crew responded, defibrillated, and provided either manual or LUCAS CPR. The team transported the mannequin through hallways and down stairs to an ambulance and drove to the hospital with CPR in progress. Critical events were manually timed while the mannequin recorded data on compressions. Twenty-three EMS providers participated. Median time to defibrillation was not different for LUCAS compared to manual CPR (p=0.97). LUCAS had a lower median number of compressions per minute (112/min vs. 125/min; IQR = 102-128 and 102-126 respectively; p<0.002), which was more consistent with current American Heart Association CPR guidelines, and percent adequate compression rate (71% vs. 40%; IQR = 21-93 and 12-88 respectively; p<0.002). In addition, LUCAS had a higher percent adequate depth (52% vs. 36%; IQR = 25-64 and 29-39 respectively; p<0.007) and lower percent total hands-off time (15% vs. 20%; IQR = 10-22 and 15-27 respectively; p<0.005). LUCAS performed no differently than manual CPR in median compression release depth, percent fully released compressions, median time hands off, or percent correct hand position. In our simulation, LUCAS had a higher rate of adequate compressions and decreased total hands-off time as compared to manual CPR. Chest compression quality may be better when using a mechanical device during patient movement in prehospital cardiac arrest patient.

  14. Sharing control between humans and automation using haptic interface: primary and secondary task performance benefits.

    PubMed

    Griffiths, Paul G; Gillespie, R Brent

    2005-01-01

    This paper describes a paradigm for human/automation control sharing in which the automation acts through a motor coupled to a machine's manual control interface. The manual interface becomes a haptic display, continually informing the human about automation actions. While monitoring by feel, users may choose either to conform to the automation or override it and express their own control intentions. This paper's objective is to demonstrate that adding automation through haptic display can be used not only to improve performance on a primary task but also to reduce perceptual demands or free attention for a secondary task. Results are presented from three experiments in which 11 participants completed a lane-following task using a motorized steering wheel on a fixed-base driving simulator. The automation behaved like a copilot, assisting with lane following by applying torques to the steering wheel. Results indicate that haptic assist improves lane following by least 30%, p < .0001, while reducing visual demand by 29%, p < .0001, or improving reaction time in a secondary tone localization task by 18 ms, p = .0009. Potential applications of this research include the design of automation interfaces based on haptics that support human/automation control sharing better than traditional push-button automation interfaces.

  15. Systematic review of intraoperative colonic irrigation vs. manual decompression in obstructed left-sided colorectal emergencies.

    PubMed

    Kam, M H; Tang, C L; Chan, E; Lim, J F; Eu, K W

    2009-09-01

    A systematic review was conducted to determine if manual decompression is a safe alternative to intraoperative colonic irrigation prior to primary anastomosis in obstructed left-sided colorectal emergencies. Search for relevant articles from 1980 to 2007 was conducted on Medline, Embase and the Cochrane Controlled Trials Register using the keywords "colonic lavage, irrigation, decompression, washout, obstructed and bowel preparation", either singularly or in combination. Trials in English publications with similar patient characteristics, inclusion criteria and outcome measures were selected for analysis. Thirty-day mortality, anastomotic leak rates and post-operative wound infection were studied as outcome variables. Analysis was performed with RevMan 4.2 software. Seven trials were identified for systematic review, with a total of 449 patients. Data from the single randomised controlled trial and one prospective comparative trial were analysed separately. Results from the remaining five studies were pooled into two arms of a composite series, one with colonic irrigation and one without. Results showed no significant difference in the anastomotic leak rates and mortality rates between the colonic irrigation and manual decompression arms in the randomised and comparative trials. The composite series, however, showed significantly better results with manual decompression (RR 6.18, 95% CI 1.67-22.86). The post-operative infection rate was similar in both groups. Manual decompression was comparable to colonic irrigation for primary anastomosis in obstructed left-sided colorectal emergencies, with no significant increase in mortality, leak or infection rates.

  16. On the Automatic Decellularisation of Porcine Aortae: A Repeatability Study Using a Non-Enzymatic Approach.

    PubMed

    O'Connor Mooney, Rory; Davis, Niall Francis; Hoey, David; Hogan, Lisa; McGloughlin, Timothy M; Walsh, Michael T

    2016-01-01

    To investigate the repeatability of automatic decellularisation of porcine aortae using a non-enzymatic approach, addressing current limitations associated with other automatic decellularisation processes. Individual porcine aortae (n = 3) were resected and every third segment (n = 4) was allocated to one of three different groups: a control or a manually or automatically decellularised group. Manual and automatic decellularisation was performed using Triton X-100 (2% v/v) and sodium deoxycholate. Protein preservation and the elimination of a galactosyl-α(1,3)galactose (GAL) epitope were measured using immunohistochemistry and protein binding assays. The presence of residual DNA was determined with gel electrophoresis and spectrophotometry. Scaffold integrity was characterised with scanning electron microscopy and uni-axial tensile testing. Manual and automatic results were compared to one another, to control groups and to current gold standards. The results were comparable to those of current gold standard decellularisation techniques. Successful repeatability was achieved, both manually and automatically, with little effect on mechanical characteristics. Complete acellularity was not confirmed in either decellularisation group. Protein preservation was consistent in both the manually and automatically decellularised groups and between each individual aorta. Elimination of GAL was not achieved. Repeatable automatic decellularisation of porcine aortae is feasible using a Triton X-100-sodium deoxycholate protocol. Protein preservation was satisfactory; however, gold standard thresholds for permissible residual DNA levels were not achieved. Future research will focus on addressing this issue by optimisation of the existing protocol for thick tissues. © 2016 S. Karger AG, Basel.

  17. A macro-micro robot for precise force applications

    NASA Technical Reports Server (NTRS)

    Marzwell, Neville I.; Wang, Yulun

    1993-01-01

    This paper describes an 8 degree-of-freedom macro-micro robot capable of performing tasks which require accurate force control. Applications such as polishing, finishing, grinding, deburring, and cleaning are a few examples of tasks which need this capability. Currently these tasks are either performed manually or with dedicated machinery because of the lack of a flexible and cost effective tool, such as a programmable force-controlled robot. The basic design and control of the macro-micro robot is described in this paper. A modular high-performance multiprocessor control system was designed to provide sufficient compute power for executing advanced control methods. An 8 degree of freedom macro-micro mechanism was constructed to enable accurate tip forces. Control algorithms based on the impedance control method were derived, coded, and load balanced for maximum execution speed on the multiprocessor system.

  18. Carryover effects of highly automated convoy driving on subsequent manual driving performance.

    PubMed

    Skottke, Eva-Maria; Debus, Günter; Wang, Lei; Huestegge, Lynn

    2014-11-01

    In the present study, we tested to what extent highly automated convoy driving involving small spacing ("platooning") may affect time headway (THW) and standard deviation of lateral position (SDLP) during subsequent manual driving. Although many previous studies have reported beneficial effects of automated driving, some research has also highlighted potential drawbacks, such as increased speed and reduced THW during the activation of semiautomated driving systems. Here, we rather focused on the question of whether switching from automated to manual driving may produce unwanted carryover effects on safety-relevant driving performance. We utilized a pre-post simulator design to measure THW and SDLP after highly automated driving and compared the data with those for a control group (manual driving throughout). Our data revealed that THW was reduced and SDLP increased after leaving the automation mode. A closer inspection of the data suggested that specifically the effect on THW is likely due to sensory and/or cognitive adaptation processes. Behavioral adaptation effects need to be taken into account in future implementations of automated convoy systems. Potential application areas of this research comprise automated freight traffic (truck convoys) and the design of driver assistance systems in general. Potential countermeasures against following at short distance as behavioral adaptation should be considered.

  19. Fully Automatic Speech-Based Analysis of the Semantic Verbal Fluency Task.

    PubMed

    König, Alexandra; Linz, Nicklas; Tröger, Johannes; Wolters, Maria; Alexandersson, Jan; Robert, Phillipe

    2018-06-08

    Semantic verbal fluency (SVF) tests are routinely used in screening for mild cognitive impairment (MCI). In this task, participants name as many items as possible of a semantic category under a time constraint. Clinicians measure task performance manually by summing the number of correct words and errors. More fine-grained variables add valuable information to clinical assessment, but are time-consuming. Therefore, the aim of this study is to investigate whether automatic analysis of the SVF could provide these as accurate as manual and thus, support qualitative screening of neurocognitive impairment. SVF data were collected from 95 older people with MCI (n = 47), Alzheimer's or related dementias (ADRD; n = 24), and healthy controls (HC; n = 24). All data were annotated manually and automatically with clusters and switches. The obtained metrics were validated using a classifier to distinguish HC, MCI, and ADRD. Automatically extracted clusters and switches were highly correlated (r = 0.9) with manually established values, and performed as well on the classification task separating HC from persons with ADRD (area under curve [AUC] = 0.939) and MCI (AUC = 0.758). The results show that it is possible to automate fine-grained analyses of SVF data for the assessment of cognitive decline. © 2018 S. Karger AG, Basel.

  20. SOWFA + Super Controller User's Manual

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Fleming, P.; Gebraad, P.; Churchfield, M.

    2013-08-01

    SOWFA + Super Controller is a modification of the NREL's SOWFA tool which allows for a user to apply multiturbine or centralized wind plant control algorithms within the high-fidelity SOWFA simulation environment. The tool is currently a branch of the main SOWFA program, but will one day will be merged into a single version. This manual introduces the tool and provides examples such that a usercan implement their own super controller and set up and run simulations. The manual only discusses enough about SOWFA itself to allow for the customization of controllers and running of simulations, and details of SOWFAmore » itself are reported elsewhere Churchfield and Lee (2013); Churchfield et al. (2012). SOWFA + Super Controller, and this manual, are in alpha mode.« less

  1. FAA Air Traffic Control Operations Concepts. Volume 5. ATCT/TCCC (airport Traffic Control Tower/Tower Control Computer Complex) Tower Controllers

    DTIC Science & Technology

    1988-07-29

    Departure List. T1.1.4.13 RESEQUENCE FOE MANUALLY 3.7.2.2.1.1.2.2-00 ARRIVAL LIST 457 3.7.2.2.1,1.2.2-11 b. Ordering - In manual ordering , the 457 a...3.7.2.2.1.1.2.3-12 b. Ordering - In manual ordering , the 457 controller shall have the capability to put a new FOE in the appropriate place in a sublist...3.7.2.2.1.1.2.2-00 ARRIVAL LIST 457 3.7.2.2.1.1.2.2-11 b. Ordering - In manual ordering , the 457 controller snall have the capability to put a new FOE in

  2. VDOT manual of practice for planning stormwater management.

    DOT National Transportation Integrated Search

    1992-01-01

    The final report is in the form of a manual of practice for the VDOT to use in planning its stormwater management strategies. The manual was proposed to aid in the selection and design of erosion control practices and stormwater control practices for...

  3. Unraveling the association between SSRI use and falls: an experimental study of risk factors for accidental falls in long-term paroxetine users.

    PubMed

    Hegeman, Judith; van den Bemt, Bart; Weerdesteyn, Vivian; Nienhuis, Bart; van Limbeek, Jacques; Duysens, Jacques

    2011-01-01

    Selective serotonin reuptake inhibitors (SSRIs) are widely used to treat depression and are also associated with an increased falls risk. However, the biological mechanism underlying accidental falls with SSRI intake has yet to be elucidated. The present experimental study was designed to investigate whether obstacle avoidance skills in long-term (>90 days), senior paroxetine users (61 ± 5.8 years) are affected during gait, simple and challenging postural balance tasks, as well as during manual reaction time tasks. The performance of the paroxetine users was compared with healthy group-matched controls (60 ± 4.8 years). The results demonstrated impaired postural balance in the paroxetine users, especially during one-legged stance or under various dual-task conditions. Although the deficit in one-legged stance could indicate vestibular involvement, this was deemed unlikely because performance of standing on compliant surface with closed eyes remained unaffected. Paroxetine use also failed to affect manual reaction times or obstacle avoidance performance. It is suggested that paroxetine affects attentional capacities particularly in conjunction with balance control. Compared with healthy seniors, long-term senior users of paroxetine seem to be at an increased risk of falling due to impairments in balance control, especially when attention has to be divided between 2 concurrent activities.

  4. Automatic and manual segmentation of healthy retinas using high-definition optical coherence tomography.

    PubMed

    Golbaz, Isabelle; Ahlers, Christian; Goesseringer, Nina; Stock, Geraldine; Geitzenauer, Wolfgang; Prünte, Christian; Schmidt-Erfurth, Ursula Margarethe

    2011-03-01

    This study compared automatic- and manual segmentation modalities in the retina of healthy eyes using high-definition optical coherence tomography (HD-OCT). Twenty retinas in 20 healthy individuals were examined using an HD-OCT system (Carl Zeiss Meditec, Inc.). Three-dimensional imaging was performed with an axial resolution of 6 μm at a maximum scanning speed of 25,000 A-scans/second. Volumes of 6 × 6 × 2 mm were scanned. Scans were analysed using a matlab-based algorithm and a manual segmentation software system (3D-Doctor). The volume values calculated by the two methods were compared. Statistical analysis revealed a high correlation between automatic and manual modes of segmentation. The automatic mode of measuring retinal volume and the corresponding three-dimensional images provided similar results to the manual segmentation procedure. Both methods were able to visualize retinal and subretinal features accurately. This study compared two methods of assessing retinal volume using HD-OCT scans in healthy retinas. Both methods were able to provide realistic volumetric data when applied to raster scan sets. Manual segmentation methods represent an adequate tool with which to control automated processes and to identify clinically relevant structures, whereas automatic procedures will be needed to obtain data in larger patient populations. © 2009 The Authors. Journal compilation © 2009 Acta Ophthalmol.

  5. Effects of gross motor function and manual function levels on performance-based ADL motor skills of children with spastic cerebral palsy.

    PubMed

    Park, Myoung-Ok

    2017-02-01

    [Purpose] The purpose of this study was to determine effects of Gross Motor Function Classification System and Manual Ability Classification System levels on performance-based motor skills of children with spastic cerebral palsy. [Subjects and Methods] Twenty-three children with cerebral palsy were included. The Assessment of Motor and Process Skills was used to evaluate performance-based motor skills in daily life. Gross motor function was assessed using Gross Motor Function Classification Systems, and manual function was measured using the Manual Ability Classification System. [Results] Motor skills in daily activities were significantly different on Gross Motor Function Classification System level and Manual Ability Classification System level. According to the results of multiple regression analysis, children categorized as Gross Motor Function Classification System level III scored lower in terms of performance based motor skills than Gross Motor Function Classification System level I children. Also, when analyzed with respect to Manual Ability Classification System level, level II was lower than level I, and level III was lower than level II in terms of performance based motor skills. [Conclusion] The results of this study indicate that performance-based motor skills differ among children categorized based on Gross Motor Function Classification System and Manual Ability Classification System levels of cerebral palsy.

  6. Child Centred Approach to Climate Change and Health Adaptation through Schools in Bangladesh: A Cluster Randomised Intervention Trial

    PubMed Central

    Kabir, Md Iqbal; Rahman, Md Bayzidur; Smith, Wayne; Lusha, Mirza Afreen Fatima; Milton, Abul Hasnat

    2015-01-01

    Background Bangladesh is one of the most vulnerable countries to climate change. People are getting educated at different levels on how to deal with potential impacts. One such educational mode was the preparation of a school manual, for high school students on climate change and health protection endorsed by the National Curriculum and Textbook Board, which is based on a 2008 World Health Organization manual. The objective of this study was to test the effectiveness of the manual in increasing the knowledge level of the school children about climate change and health adaptation. Methods This cluster randomized intervention trial involved 60 schools throughout Bangladesh, with 3293 secondary school students participating. School upazilas (sub-districts) were randomised into intervention and control groups, and two schools from each upazila were randomly selected. All year seven students from both groups of schools sat for a pre-test of 30 short questions of binary response. A total of 1515 students from 30 intervention schools received the intervention through classroom training based on the school manual and 1778 students of the 30 control schools did not get the manual but a leaflet on climate change and health issues. Six months later, a post-intervention test of the same questionnaire used in the pre-test was performed at both intervention and control schools. The pre and post test scores were analysed along with the demographic data by using random effects model. Results None of the various school level and student level variables were significantly different between the control and intervention group. However, the intervention group had a 17.42% (95% CI: 14.45 to 20.38, P = <0.001) higher score in the post-test after adjusting for pre-test score and other covariates in a multi-level linear regression model. Conclusions These results suggest that school-based intervention for climate change and health adaptation is effective for increasing the knowledge level of school children on this topic. PMID:26252381

  7. Nevada National Security Site Radiological Control Manual

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Radiological Control Managers’ Council

    2012-03-26

    This document supersedes DOE/NV/25946--801, 'Nevada Test Site Radiological Control Manual,' Revision 1 issued in February 2010. Brief Description of Revision: A complete revision to reflect a recent change in name for the NTS; changes in name for some tenant organizations; and to update references to current DOE policies, orders, and guidance documents. Article 237.2 was deleted. Appendix 3B was updated. Article 411.2 was modified. Article 422 was re-written to reflect the wording of DOE O 458.1. Article 431.6.d was modified. The glossary was updated. This manual contains the radiological control requirements to be used for all radiological activities conducted bymore » programs under the purview of the U.S. Department of Energy (DOE) and the U.S. Department of Energy, National Nuclear Security Administration Nevada Site Office (NNSA/NSO). Compliance with these requirements will ensure compliance with Title 10 Code of Federal Regulations (CFR) Part 835, 'Occupational Radiation Protection.' Programs covered by this manual are located at the Nevada National Security Site (NNSS); Nellis Air Force Base and North Las Vegas, Nevada; Santa Barbara and Livermore, California; and Andrews Air Force Base, Maryland. In addition, fieldwork by NNSA/NSO at other locations is covered by this manual. Current activities at NNSS include operating low-level radioactive and mixed waste disposal facilities for United States defense-generated waste, assembly and execution of subcritical experiments, assembly/disassembly of special experiments, the storage and use of special nuclear materials, performing criticality experiments, emergency responder training, surface cleanup and site characterization of contaminated land areas, environmental activity by the University system, and nonnuclear test operations, such as controlled spills of hazardous materials at the Hazardous Materials Spill Center. Currently, the major potential for occupational radiation exposure is associated with the burial of low-level radioactive waste and the handling of radioactive sources. Remediation of contaminated land areas may also result in radiological exposures.« less

  8. Child Centred Approach to Climate Change and Health Adaptation through Schools in Bangladesh: A Cluster Randomised Intervention Trial.

    PubMed

    Kabir, Md Iqbal; Rahman, Md Bayzidur; Smith, Wayne; Lusha, Mirza Afreen Fatima; Milton, Abul Hasnat

    2015-01-01

    Bangladesh is one of the most vulnerable countries to climate change. People are getting educated at different levels on how to deal with potential impacts. One such educational mode was the preparation of a school manual, for high school students on climate change and health protection endorsed by the National Curriculum and Textbook Board, which is based on a 2008 World Health Organization manual. The objective of this study was to test the effectiveness of the manual in increasing the knowledge level of the school children about climate change and health adaptation. This cluster randomized intervention trial involved 60 schools throughout Bangladesh, with 3293 secondary school students participating. School upazilas (sub-districts) were randomised into intervention and control groups, and two schools from each upazila were randomly selected. All year seven students from both groups of schools sat for a pre-test of 30 short questions of binary response. A total of 1515 students from 30 intervention schools received the intervention through classroom training based on the school manual and 1778 students of the 30 control schools did not get the manual but a leaflet on climate change and health issues. Six months later, a post-intervention test of the same questionnaire used in the pre-test was performed at both intervention and control schools. The pre and post test scores were analysed along with the demographic data by using random effects model. None of the various school level and student level variables were significantly different between the control and intervention group. However, the intervention group had a 17.42% (95% CI: 14.45 to 20.38, P = <0.001) higher score in the post-test after adjusting for pre-test score and other covariates in a multi-level linear regression model. These results suggest that school-based intervention for climate change and health adaptation is effective for increasing the knowledge level of school children on this topic.

  9. An Overview of the Automated Dispatch Controller Algorithms in the System Advisor Model (SAM)

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    DiOrio, Nicholas A

    2017-11-22

    Three automatic dispatch modes have been added to the battery model within the System Adviser Model. These controllers have been developed to perform peak shaving in an automated fashion, providing users with a way to see the benefit of reduced demand charges without manually programming a complicated dispatch control. A flexible input option allows more advanced interaction with the automated controller. This document will describe the algorithms in detail and present brief results on its use and limitations.

  10. A simple highly efficient non invasive EMG-based HMI.

    PubMed

    Vitiello, N; Olcese, U; Oddo, C M; Carpaneto, J; Micera, S; Carrozza, M C; Dario, P

    2006-01-01

    Muscle activity recorded non-invasively is sufficient to control a mobile robot if it is used in combination with an algorithm for its asynchronous analysis. In this paper, we show that several subjects successfully can control the movements of a robot in a structured environment made up of six rooms by contracting two different muscles using a simple algorithm. After a small training period, subjects were able to control the robot with performances comparable to those achieved manually controlling the robot.

  11. Realism and Effectiveness of Robotic Moving Targets

    DTIC Science & Technology

    2017-04-01

    scenario or be manually controlled . The targets can communicate with other nearby targets, which means they can move independently, as a group , or...present a realistic three- dimensional human-sized target that can freely move with semi-autonomous control . The U.S. Army Research Institute for...Procedure: Performance and survey data were collected during multiple training exercises from Soldiers who engaged the RHTTs. Different groups

  12. A trajectory generation and system characterization model for cislunar low-thrust spacecraft. Volume 2: Technical manual

    NASA Technical Reports Server (NTRS)

    Korsmeyer, David J.; Pinon, Elfego, III; Oconnor, Brendan M.; Bilby, Curt R.

    1990-01-01

    The documentation of the Trajectory Generation and System Characterization Model for the Cislunar Low-Thrust Spacecraft is presented in Technical and User's Manuals. The system characteristics and trajectories of low thrust nuclear electric propulsion spacecraft can be generated through the use of multiple system technology models coupled with a high fidelity trajectory generation routine. The Earth to Moon trajectories utilize near Earth orbital plane alignment, midcourse control dependent upon the spacecraft's Jacobian constant, and capture to target orbit utilizing velocity matching algorithms. The trajectory generation is performed in a perturbed two-body equinoctial formulation and the restricted three-body formulation. A single control is determined by the user for the interactive midcourse portion of the trajectory. The full spacecraft system characteristics and trajectory are provided as output.

  13. Multi-level manual and autonomous control superposition for intelligent telerobot

    NASA Technical Reports Server (NTRS)

    Hirai, Shigeoki; Sato, T.

    1989-01-01

    Space telerobots are recognized to require cooperation with human operators in various ways. Multi-level manual and autonomous control superposition in telerobot task execution is described. The object model, the structured master-slave manipulation system, and the motion understanding system are proposed to realize the concept. The object model offers interfaces for task level and object level human intervention. The structured master-slave manipulation system offers interfaces for motion level human intervention. The motion understanding system maintains the consistency of the knowledge through all the levels which supports the robot autonomy while accepting the human intervention. The superposing execution of the teleoperational task at multi-levels realizes intuitive and robust task execution for wide variety of objects and in changeful environment. The performance of several examples of operating chemical apparatuses is shown.

  14. 32 CFR 117.54 - Policy.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... Agency Central Security Service (NSA/CSS) Policy Manual 3-16, “Control of Communications Security Material” (available to authorized users of SIPRNET at www.iad.nsa.smil.mil/resources/library/nsa_office_of_policy_section/pdf/NSA_CSS_MAN-3-16_080505.pdf). (b) Adversely affecting the performance of classified...

  15. 40 CFR 60.59b - Reporting and recordkeeping requirements.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... monitor mercury or dioxin/furan instead of conducting performance testing using EPA manual test methods, all integrated 24-hour mercury concentrations or all integrated 2-week dioxin/furan concentrations as... actions taken. (4) For affected facilities that apply activated carbon for mercury or dioxin/furan control...

  16. Blended shared control utilizing online identification : Regulating grasping forces of a surrogate surgical grasper.

    PubMed

    Stephens, Trevor K; Kong, Nathan J; Dockter, Rodney L; O'Neill, John J; Sweet, Robert M; Kowalewski, Timothy M

    2018-06-01

    Surgical robots are increasingly common, yet routine tasks such as tissue grasping remain potentially harmful with high occurrences of tissue crush injury due to the lack of force feedback from the grasper. This work aims to investigate whether a blended shared control framework which utilizes real-time identification of the object being grasped as part of the feedback may help address the prevalence of tissue crush injury in robotic surgeries. This work tests the proposed shared control framework and tissue identification algorithm on a custom surrogate surgical robotic grasping setup. This scheme utilizes identification of the object being grasped as part of the feedback to regulate to a desired force. The blended shared control is arbitrated between human and an implicit force controller based on a computed confidence in the identification of the grasped object. The online identification is performed using least squares based on a nonlinear tissue model. Testing was performed on five silicone tissue surrogates. Twenty grasps were conducted, with half of the grasps performed under manual control and half of the grasps performed with the proposed blended shared control, to test the efficacy of the control scheme. The identification method resulted in an average of 95% accuracy across all time samples of all tissue grasps using a full leave-grasp-out cross-validation. There was an average convergence time of [Formula: see text] ms across all training grasps for all tissue surrogates. Additionally, there was a reduction in peak forces induced during grasping for all tissue surrogates when applying blended shared control online. The blended shared control using online identification more successfully regulated grasping forces to the desired target force when compared with manual control. The preliminary work on this surrogate setup for surgical grasping merits further investigation on real surgical tools and with real human tissues.

  17. Coordinating and Performing Activities for Employer. Preparing Expense Reports. Student Manual and Teacher's Manual.

    ERIC Educational Resources Information Center

    Jones, Maleeta M.

    Supporting performance objective 13 of the V-TECS (Vocational-Technical Education Consortium of States) Secretarial Catalog, both a set of student materials and an instructor's manual on preparing employer's business expense statements are included in this packet. (The packet is the fourth in a set of four on coordinating and performing activities…

  18. The role of treatment timing and mode of stimulation in the treatment of primary dysmenorrhea with acupuncture: An exploratory randomised controlled trial.

    PubMed

    Armour, Mike; Dahlen, Hannah G; Zhu, Xiaoshu; Farquhar, Cindy; Smith, Caroline A

    2017-01-01

    We examined the effect of changing treatment timing and the use of manual, electro acupuncture on the symptoms of primary dysmenorrhea. A randomised controlled trial was performed with four arms, low frequency manual acupuncture (LF-MA), high frequency manual acupuncture (HF-MA), low frequency electro acupuncture (LF-EA) and high frequency electro acupuncture (HF-EA). A manualised trial protocol was used to allow differentiation and individualized treatment over three months. A total of 74 women were randomly assigned to one of the four groups (LF-MA n = 19, HF-MA n = 18, LF-EA n = 18, HF-EA n = 19). Twelve treatments were performed over three menstrual cycles, either once per week (LF groups) or three times in the week prior to menses (HF groups). All groups received a treatment in the first 48 hours of menses. The primary outcome was the reduction in peak menstrual pain at 12 months from trial entry. During the treatment period and nine month follow-up all groups showed statistically significant (p < .001) reductions in peak and average menstrual pain compared to baseline but there were no differences between groups (p > 0.05). Health related quality of life increased significantly in six domains in groups having high frequency of treatment compared to two domains in low frequency groups. Manual acupuncture groups required less analgesic medication than electro-acupuncture groups (p = 0.02). HF-MA was most effective in reducing secondary menstrual symptoms compared to both-EA groups (p<0.05). Acupuncture treatment reduced menstrual pain intensity and duration after three months of treatment and this was sustained for up to one year after trial entry. The effect of changing mode of stimulation or frequency of treatment on menstrual pain was not significant. This may be due to a lack of power. The role of acupuncture stimulation on menstrual pain needs to be investigated in appropriately powered randomised controlled trials.

  19. The role of treatment timing and mode of stimulation in the treatment of primary dysmenorrhea with acupuncture: An exploratory randomised controlled trial

    PubMed Central

    Dahlen, Hannah G.; Zhu, Xiaoshu; Farquhar, Cindy; Smith, Caroline A.

    2017-01-01

    Objectives We examined the effect of changing treatment timing and the use of manual, electro acupuncture on the symptoms of primary dysmenorrhea. Methods A randomised controlled trial was performed with four arms, low frequency manual acupuncture (LF-MA), high frequency manual acupuncture (HF-MA), low frequency electro acupuncture (LF-EA) and high frequency electro acupuncture (HF-EA). A manualised trial protocol was used to allow differentiation and individualized treatment over three months. A total of 74 women were randomly assigned to one of the four groups (LF-MA n = 19, HF-MA n = 18, LF-EA n = 18, HF-EA n = 19). Twelve treatments were performed over three menstrual cycles, either once per week (LF groups) or three times in the week prior to menses (HF groups). All groups received a treatment in the first 48 hours of menses. The primary outcome was the reduction in peak menstrual pain at 12 months from trial entry. Results During the treatment period and nine month follow-up all groups showed statistically significant (p < .001) reductions in peak and average menstrual pain compared to baseline but there were no differences between groups (p > 0.05). Health related quality of life increased significantly in six domains in groups having high frequency of treatment compared to two domains in low frequency groups. Manual acupuncture groups required less analgesic medication than electro-acupuncture groups (p = 0.02). HF-MA was most effective in reducing secondary menstrual symptoms compared to both–EA groups (p<0.05). Conclusion Acupuncture treatment reduced menstrual pain intensity and duration after three months of treatment and this was sustained for up to one year after trial entry. The effect of changing mode of stimulation or frequency of treatment on menstrual pain was not significant. This may be due to a lack of power. The role of acupuncture stimulation on menstrual pain needs to be investigated in appropriately powered randomised controlled trials. PMID:28700680

  20. Experimental analysis of drilling process in cortical bone.

    PubMed

    Wang, Wendong; Shi, Yikai; Yang, Ning; Yuan, Xiaoqing

    2014-02-01

    Bone drilling is an essential part in orthopaedics, traumatology and bone biopsy. Prediction and control of drilling forces and torque are critical to the success of operations involving bone drilling. This paper studied the drilling force, torque and drilling process with automatic and manual drill penetrating into bovine cortical bone. The tests were performed on a drilling system which is used to drill and measure forces and torque during drilling. The effects of drilling speed, feed rate and drill bit diameter on force and torque were discussed separately. The experimental results were proven to be in accordance with the mathematic expressions introduced in this paper. The automatic drilling saved drilling time by 30-60% in the tested range and created less vibration, compared to manual drilling. The deviation between maximum and average force of the automatic drilling was 5N but 25N for manual drilling. To conclude, using the automatic method has significant advantages in control drilling force, torque and drilling process in bone drilling. Copyright © 2013 IPEM. Published by Elsevier Ltd. All rights reserved.

  1. Development of automation software for neutron activation analysis process in Malaysian nuclear agency

    NASA Astrophysics Data System (ADS)

    Yussup, N.; Rahman, N. A. A.; Ibrahim, M. M.; Mokhtar, M.; Salim, N. A. A.; Soh@Shaari, S. C.; Azman, A.

    2017-01-01

    Neutron Activation Analysis (NAA) process has been established in Malaysian Nuclear Agency (Nuclear Malaysia) since 1980s. Most of the procedures established especially from sample registration to sample analysis are performed manually. These manual procedures carried out by the NAA laboratory personnel are time consuming and inefficient. Hence, a software to support the system automation is developed to provide an effective method to replace redundant manual data entries and produce faster sample analysis and calculation process. This paper describes the design and development of automation software for NAA process which consists of three sub-programs. The sub-programs are sample registration, hardware control and data acquisition; and sample analysis. The data flow and connection between the sub-programs will be explained. The software is developed by using National Instrument LabView development package.

  2. Structural Pest Control.

    ERIC Educational Resources Information Center

    Kahn, M. S.; Hoffman, W. M.

    This manual is designed for those who seek certification as pesticide applicators for industrial, institutional, structural, and health-related pest control. It is divided into six sections covering general pest control, wood-destroying organisms, bird control, fumigation, rodent control, and industrial weed control. The manual gives information…

  3. High-occupancy vehicle guidelines for planning, design and operations

    DOT National Transportation Integrated Search

    2003-08-01

    These guidelines are not intended to supersede Caltrans : Transportation Planning Manual, Project Development : Procedures Manual, Highway Design Manual, Manual : on Uniform Traffic Control Devices (MUTCD) and : California Supplement to the MUTCD ...

  4. The effects of speech controls on performance in advanced helicopters in a double stimulation paradigm

    NASA Technical Reports Server (NTRS)

    Bortolussi, Michael R.; Vidulich, Michael A.

    1991-01-01

    The potential benefit of speech as a control modality has been investigated with mixed results. Earlier studies suggests that speech controls can reduce the potential of manual control overloads and improve time-sharing performance. However, these benefits were not without costs. Pilots reported higher workload levels associated with the use of speech controls. To further investigate these previous findings, an experiment was conducted in a simulation of an advanced single-pilot, scout/attack helicopter at NASA-Ames' ICAB (interchangeable cab) facility. Objective performance data suggested that speech control modality was effective in reducing interference of discrete, time-shared responses during continuous flight control activity. Subjective ratings, however, indicated that the speech control modality increased workload. Post-flight debriefing indicated that these results were mainly due to the increased effort to speak precisely to a less than perfect voice recognition system.

  5. 78 FR 24817 - Visual-Manual NHTSA Driver Distraction Guidelines for In-Vehicle Electronic Devices

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-04-26

    ...The National Highway Traffic Safety Administration (NHTSA) is concerned about the effects of distraction on motor vehicle safety due to drivers' use of electronic devices. Consequently, NHTSA is issuing nonbinding, voluntary Driver Distraction Guidelines (NHTSA Guidelines) to promote safety by discouraging the introduction of excessively distracting devices in vehicles. This notice announces the issuance of the final version of the first phase of the NHTSA Guidelines. This first phase applies to original equipment (OE) in-vehicle electronic devices used by the driver to perform secondary tasks (communications, entertainment, information gathering, navigation tasks, etc. are considered secondary tasks) through visual-manual means (i.e., the driver looks at a device, manipulates a device-related control with his or her hand, and/or watches for visual feedback). The NHTSA Guidelines list certain secondary tasks believed by the agency to interfere inherently with a driver's ability to safely control the vehicle. The NHTSA Guidelines recommend that in-vehicle devices be designed so that they cannot be used by the driver to perform these inherently distracting secondary tasks while driving. For all other visual-manual secondary tasks, the NHTSA Guidelines specify a test method for measuring eye glance behavior during those tasks. Eye glance metrics are compared to acceptance criteria to evaluate whether a task interferes too much with driver attention, rendering it unsuitable for a driver to perform while driving. If a task does not meet the acceptance criteria, the NHTSA Guidelines recommend that the task be made inaccessible for performance by the driver while driving. In addition, the NHTSA Guidelines contain several recommendations to limit and reduce the potential for distraction associated with the use of OE in-vehicle electronic devices.

  6. Airport Performance Model : Volume 2 - User's Manual and Program Documentation

    DOT National Transportation Integrated Search

    1978-10-01

    Volume II contains a User's manual and program documentation for the Airport Performance Model. This computer-based model is written in FORTRAN IV for the DEC-10. The user's manual describes the user inputs to the interactive program and gives sample...

  7. Sixteenth Annual Conference on Manual Control

    NASA Technical Reports Server (NTRS)

    1982-01-01

    Manual control is discussed in terms of operator modeling, measurement of human response, mental workload, pilot/operator opinion, effects of motion, aircraft displays, supervisory control, automobile driving, and remote manipulation.

  8. The influence of ship motion of manual control skills

    NASA Technical Reports Server (NTRS)

    Mcleod, P.; Poulton, C.; Duross, H.; Lewis, W.

    1981-01-01

    The effects of ship motion on a range of typical manual control skills were examined on the Warren Spring ship motion simulator driven in heave, pitch, and roll by signals taken from the frigate HMS Avenger at 13 m/s (25 knots) into a force 4 wind. The motion produced a vertical r.m.s. acceleration of 0.024g, mostly between 0.1 and 0.3 Hz, with comparatively little pitch or roll. A task involving unsupported arm movements was seriously affected by the motion; a pursuit tracking task showed a reliable decrement although it was still performed reasonably well (pressure and free moving tracking controls were affected equally by the motion); a digit keying task requiring ballistic hand movements was unaffected. There was no evidence that these effects were caused by sea sickness. The differing response to motion of the different tasks, from virtual destruction to no effect, suggests that a major benefit could come from an attempt to design the man/control interface onboard ship around motion resistant tasks.

  9. Sensor fault-tolerant control for gear-shifting engaging process of automated manual transmission

    NASA Astrophysics Data System (ADS)

    Li, Liang; He, Kai; Wang, Xiangyu; Liu, Yahui

    2018-01-01

    Angular displacement sensor on the actuator of automated manual transmission (AMT) is sensitive to fault, and the sensor fault will disturb its normal control, which affects the entire gear-shifting process of AMT and results in awful riding comfort. In order to solve this problem, this paper proposes a method of fault-tolerant control for AMT gear-shifting engaging process. By using the measured current of actuator motor and angular displacement of actuator, the gear-shifting engaging load torque table is built and updated before the occurrence of the sensor fault. Meanwhile, residual between estimated and measured angular displacements is used to detect the sensor fault. Once the residual exceeds a determined fault threshold, the sensor fault is detected. Then, switch control is triggered, and the current observer and load torque table estimates an actual gear-shifting position to replace the measured one to continue controlling the gear-shifting process. Numerical and experiment tests are carried out to evaluate the reliability and feasibility of proposed methods, and the results show that the performance of estimation and control is satisfactory.

  10. Manual on Bibliographic Control.

    ERIC Educational Resources Information Center

    International Federation of Library Associations, The Hague (Netherlands).

    This manual outlines objectives, functions, and methods for establishing national bibliographic control as part of the development of a worldwide system for the control and exchange of bibliographic information. Chapters cover: (1) definitions of bibliographic control and related concepts including Universal Bibliographic Control (UBC) and…

  11. The influence of spatial ability and experience on performance during spaceship rendezvous and docking.

    PubMed

    Du, Xiaoping; Zhang, Yijing; Tian, Yu; Huang, Weifen; Wu, Bin; Zhang, Jingyu

    2015-01-01

    Manual rendezvous and docking (manual RVD) is a challenging space task for astronauts. Previous research showed a correlation between spatial ability and manual RVD skills among participants at early stages of training, but paid less attention to experts. Therefore, this study tried to explore the role of spatial ability in manual RVD skills in two groups of trainees, one relatively inexperienced and the other experienced operators. Additionally, mental rotation has been proven essential in RVD and was tested in this study among 27 male participants, 15 novices, and 12 experts. The participants performed manual RVD tasks in a high fidelity simulator. Results showed that experience moderated the relation between mental rotation ability and manual RVD performance. On one hand, novices with high mental rotation ability tended to perform that RVD task more successfully; on the other hand, experts with high mental rotation ability showed not only no performance advantage in the final stage of the RVD task, but had certain disadvantages in their earlier processes. Both theoretical and practical implications were discussed.

  12. The influence of spatial ability and experience on performance during spaceship rendezvous and docking

    PubMed Central

    Du, Xiaoping; Zhang, Yijing; Tian, Yu; Huang, Weifen; Wu, Bin; Zhang, Jingyu

    2015-01-01

    Manual rendezvous and docking (manual RVD) is a challenging space task for astronauts. Previous research showed a correlation between spatial ability and manual RVD skills among participants at early stages of training, but paid less attention to experts. Therefore, this study tried to explore the role of spatial ability in manual RVD skills in two groups of trainees, one relatively inexperienced and the other experienced operators. Additionally, mental rotation has been proven essential in RVD and was tested in this study among 27 male participants, 15 novices, and 12 experts. The participants performed manual RVD tasks in a high fidelity simulator. Results showed that experience moderated the relation between mental rotation ability and manual RVD performance. On one hand, novices with high mental rotation ability tended to perform that RVD task more successfully; on the other hand, experts with high mental rotation ability showed not only no performance advantage in the final stage of the RVD task, but had certain disadvantages in their earlier processes. Both theoretical and practical implications were discussed. PMID:26236252

  13. Safety performance testing of a modified Oregon multidirectional slip-base sign support : FOIL test numbers 98F002 and 98F004

    DOT National Transportation Integrated Search

    1997-07-01

    This project evaluated the effectiveness of symbol traffic signs for young, middle-aged and elderly drivers. Daytime legibility distance and comprehension of 85 symbols in the Manual on Uniform Traffic Control Devices (MUTCD) were measured. Legibilit...

  14. 40 CFR 85.2110 - Submission of owners' manuals and warranty statements to EPA.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... Control System Performance Warranty Regulations and Voluntary Aftermarket Part Certification Program § 85... booklet (if applicable) for each model vehicle, except that, if the same warranty information is to be... with a statement that such copies are complete and accurate representation of the warranty information...

  15. Corpus-Based Optimization of Language Models Derived from Unification Grammars

    NASA Technical Reports Server (NTRS)

    Rayner, Manny; Hockey, Beth Ann; James, Frankie; Bratt, Harry; Bratt, Elizabeth O.; Gawron, Mark; Goldwater, Sharon; Dowding, John; Bhagat, Amrita

    2000-01-01

    We describe a technique which makes it feasible to improve the performance of a language model derived from a manually constructed unification grammar, using low-quality untranscribed speech data and a minimum of human annotation. The method is on a medium-vocabulary spoken language command and control task.

  16. Development of a short course : manual on uniform traffic control devices for the Alabama Department of Transportation

    DOT National Transportation Integrated Search

    2002-05-31

    This project developed a one-day short course on the Manual on Uniform Manual Traffic Control Devices (MUTCD) for the Alabama Department of Transportation (ALDOT). Portions of the MUTCD are changed from time to time, and in 2001a significantly revise...

  17. A corrosion control manual for rail rapid transit

    NASA Technical Reports Server (NTRS)

    Gilbert, L. O.; Fitzgerald, J. F., II; Menke, J. T.

    1982-01-01

    In 1979, during the planning stage of the Metropolitan Dade County Transit System, the need was expressed for a corrosion control manual oriented to urban rapid transit system use. This manual responds to that need. The objective of the manual is to aid rail rapid transit agencies by providing practical solutions to selected corrosion problems. The scope of the manual encompasses corrosion problems of the facilities of rapid transit systems: structures and tracks, platforms and stations, power and signals, and cars. It also discusses stray electric current corrosion. Both design and maintenance solutions are provided for each problem. Also included are descriptions of the types of corrosion and their causes, descriptions of rapid transit properties, a list of corrosion control committees and NASA, DOD, and ASTM specifications and design criteria to which reference is made in the manual. A bibliography of papers and excerpts of reports and a glossary of frequency used terms are provided.

  18. Manual Dexterity in Schizophrenia—A Neglected Clinical Marker?

    PubMed Central

    Térémetz, Maxime; Carment, Loïc; Brénugat-Herne, Lindsay; Croca, Marta; Bleton, Jean-Pierre; Krebs, Marie-Odile; Maier, Marc A.; Amado, Isabelle; Lindberg, Påvel G.

    2017-01-01

    Impaired manual dexterity is commonly observed in schizophrenia. However, a quantitative description of key sensorimotor components contributing to impaired dexterity is lacking. Whether the key components of dexterity are differentially affected and how they relate to clinical characteristics also remains unclear. We quantified the degree of dexterity in 35 stabilized patients with schizophrenia and in 20 age-matched control subjects using four visuomotor tasks: (i) force tracking to quantify visuomotor precision, (ii) sequential finger tapping to measure motor sequence recall, (iii) single-finger tapping to assess temporal regularity, and (iv) multi-finger tapping to measure independence of finger movements. Diverse clinical and neuropsychological tests were also applied. A patient subgroup (N = 15) participated in a 14-week cognitive remediation protocol and was assessed before and after remediation. Compared to control subjects, patients with schizophrenia showed greater error in force tracking, poorer recall of tapping sequences, decreased tapping regularity, and reduced degree of finger individuation. A composite performance measure discriminated patients from controls with sensitivity = 0.79 and specificity = 0.9. Aside from force-tracking error, no other dexterity components correlated with antipsychotic medication. In patients, some dexterity components correlated with neurological soft signs, Positive and Negative Syndrome Scale (PANSS), or neuropsychological scores. This suggests differential cognitive contributions to these components. Cognitive remediation lead to significant improvement in PANSS, tracking error, and sequence recall (without change in medication). These findings show that multiple aspects of sensorimotor control contribute to impaired manual dexterity in schizophrenia. Only visuomotor precision was related to antipsychotic medication. Good diagnostic accuracy and responsiveness to treatment suggest that manual dexterity may represent a useful clinical marker in schizophrenia. PMID:28740470

  19. 14 CFR 27.1587 - Performance information.

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ....1587 Aeronautics and Space FEDERAL AVIATION ADMINISTRATION, DEPARTMENT OF TRANSPORTATION AIRCRAFT... Manual and Approved Manual Material § 27.1587 Performance information. (a) The Rotorcraft Flight Manual... determined in accordance with § 27.65(a)(2)(i). (Secs. 313(a), 601, 603, 604, and 605 of the Federal Aviation...

  20. Dual Extended Kalman Filter for the Identification of Time-Varying Human Manual Control Behavior

    NASA Technical Reports Server (NTRS)

    Popovici, Alexandru; Zaal, Peter M. T.; Pool, Daan M.

    2017-01-01

    A Dual Extended Kalman Filter was implemented for the identification of time-varying human manual control behavior. Two filters that run concurrently were used, a state filter that estimates the equalization dynamics, and a parameter filter that estimates the neuromuscular parameters and time delay. Time-varying parameters were modeled as a random walk. The filter successfully estimated time-varying human control behavior in both simulated and experimental data. Simple guidelines are proposed for the tuning of the process and measurement covariance matrices and the initial parameter estimates. The tuning was performed on simulation data, and when applied on experimental data, only an increase in measurement process noise power was required in order for the filter to converge and estimate all parameters. A sensitivity analysis to initial parameter estimates showed that the filter is more sensitive to poor initial choices of neuromuscular parameters than equalization parameters, and bad choices for initial parameters can result in divergence, slow convergence, or parameter estimates that do not have a real physical interpretation. The promising results when applied to experimental data, together with its simple tuning and low dimension of the state-space, make the use of the Dual Extended Kalman Filter a viable option for identifying time-varying human control parameters in manual tracking tasks, which could be used in real-time human state monitoring and adaptive human-vehicle haptic interfaces.

  1. Modular control subsystems for use in solar heating systems for multi-family dwellings

    NASA Technical Reports Server (NTRS)

    1977-01-01

    Progress in the development of solar heating modular control subsystems is reported. Circuit design, circuit drawings, and printed circuit board layout are discussed along with maintenance manuals, installation instructions, and verification and acceptance tests. Calculations made to determine the predicted performance of the differential thermostat are given including details and results of tests for the offset temperature, and boil and freeze protect points.

  2. Hand Path Priming in Manual Obstacle Avoidance: Evidence that the Dorsal Stream Does Not Only Control Visually Guided Actions in Real Time

    ERIC Educational Resources Information Center

    Jax, Steven A.; Rosenbaum, David A.

    2007-01-01

    According to a prominent theory of human perception and performance (M. A. Goodale & A. D. Milner, 1992), the dorsal, action-related stream only controls visually guided actions in real time. Such a system would be predicted to show little or no action priming from previous experience. The 3 experiments reported here were designed to determine…

  3. Physics-Based Robot Motion Planning in Dynamic Multi-Body Environments

    DTIC Science & Technology

    2010-05-10

    be actuated by external influences and interactions, such as being carried or pushed. Foreign-controlled bodies are actively actuated, but by external...from the action space A. How this action is generated can strongly influence the overall behavior and performance of our planner and will be discussed in...evolving game-state and unpredictable player -input), an animator cannot manually adjust these controls in advance. The planning approaches introduced in

  4. A dual-user teleoperation system with Online Authority Adjustment for haptic training.

    PubMed

    Fei Liu; Leleve, Arnaud; Eberard, Damien; Redarce, Tanneguy

    2015-08-01

    This paper introduces a dual-user teleoperation system for hands-on medical training. A shared control based architecture is presented for authority management. In this structure, the combination of control signals is obtained using a dominance factor. Its main improvement is Online Authority Adjustment (OAA): the authority can be adjusted manually/automatically during the training progress. Experimental results are provided to validate the performances of the system.

  5. The ability of a sustained within-session finding of pain reduction during traction to dictate improved outcomes from a manual therapy approach on patients with osteoarthritis of the hip.

    PubMed

    Wright, Alexis A; Abbott, J Haxby; Baxter, Dave; Cook, Chad

    2010-09-01

    THE OBJECTIVES OF THIS STUDY WERE TO: (1) determine the association of a within-session finding after traction of the hip with self-report of well-being, pain, and self-report of function at 9 weeks; and (2) to determine if the interactions between the within-session finding and the outcome measure are different between groups of patients with hip OA who receive and who do not receive manual therapy. Data were retrospectively analysed in 70 subjects who were part of a randomized control trial. Correlation analyses of within-session findings from the initial visit after traction of a concordantly painful hip were compared to self-report measures for function, pain, and well-being at 9 weeks. A comparison of slope coefficients between manual therapy and non-manual therapy groups was performed to determine the interactive aspects of the within-session finding. Although the correlations for the manual therapy group were higher than for the supervised neglect group, none of the correlational analyses for both groups was strong or significant. Significant differences in the slope coefficients for well-being and pain were found, suggesting that the interactions between the within-session findings and the targeted outcomes were different in the manual therapy group versus supervised neglect group. These findings suggest that within-session findings during the initial evaluation are not strongly related to a positive outcome after manual therapy, although the interaction of the finding of a within-session change and the use of manual therapy is more compelling than the finding in a sample of patients who did not receive manual therapy.

  6. Online learning control using adaptive critic designs with sparse kernel machines.

    PubMed

    Xu, Xin; Hou, Zhongsheng; Lian, Chuanqiang; He, Haibo

    2013-05-01

    In the past decade, adaptive critic designs (ACDs), including heuristic dynamic programming (HDP), dual heuristic programming (DHP), and their action-dependent ones, have been widely studied to realize online learning control of dynamical systems. However, because neural networks with manually designed features are commonly used to deal with continuous state and action spaces, the generalization capability and learning efficiency of previous ACDs still need to be improved. In this paper, a novel framework of ACDs with sparse kernel machines is presented by integrating kernel methods into the critic of ACDs. To improve the generalization capability as well as the computational efficiency of kernel machines, a sparsification method based on the approximately linear dependence analysis is used. Using the sparse kernel machines, two kernel-based ACD algorithms, that is, kernel HDP (KHDP) and kernel DHP (KDHP), are proposed and their performance is analyzed both theoretically and empirically. Because of the representation learning and generalization capability of sparse kernel machines, KHDP and KDHP can obtain much better performance than previous HDP and DHP with manually designed neural networks. Simulation and experimental results of two nonlinear control problems, that is, a continuous-action inverted pendulum problem and a ball and plate control problem, demonstrate the effectiveness of the proposed kernel ACD methods.

  7. Remote controlled robot assisted cardiac navigation: feasibility assessment and validation in a porcine model.

    PubMed

    Ganji, Yusof; Janabi-Sharifi, Farrokh; Cheema, Asim N

    2011-12-01

    Despite the recent advances in catheter design and technology, intra-cardiac navigation during electrophysiology procedures remains challenging. Incorporation of imaging along with magnetic or robotic guidance may improve navigation accuracy and procedural safety. In the present study, the in vivo performance of a novel remote controlled Robot Assisted Cardiac Navigation System (RACN) was evaluated in a porcine model. The navigation catheter and target sensor were advanced to the right atrium using fluoroscopic and intra-cardiac echo guidance. The target sensor was positioned at three target locations in the right atrium (RA) and the navigation task was completed by an experienced physician using both manual and RACN guidance. The navigation time, final distance between the catheter tip and target sensor, and variability in final catheter tip position were determined and compared for manual and RACN guided navigation. The experiments were completed in three animals and five measurements recorded for each target location. The mean distance (mm) between catheter tip and target sensor at the end of the navigation task was significantly less using RACN guidance compared with manual navigation (5.02 ± 0.31 vs. 9.66 ± 2.88, p = 0.050 for high RA, 9.19 ± 1.13 vs. 13.0 ± 1.00, p = 0.011 for low RA and 6.77 ± 0.59 vs. 15.66 ± 2.51, p = 0.003 for tricuspid valve annulus). The average time (s) needed to complete the navigation task was significantly longer by RACN guided navigation compared with manual navigation (43.31 ± 18.19 vs. 13.54 ± 1.36, p = 0.047 for high RA, 43.71 ± 11.93 vs. 22.71 ± 3.79, p = 0.043 for low RA and 37.84 ± 3.71 vs. 16.13 ± 4.92, p = 0.003 for tricuspid valve annulus. RACN guided navigation resulted in greater consistency in performance compared with manual navigation as evidenced by lower variability in final distance measurements (0.41 vs. 0.99 mm, p = 0.04). This study demonstrated the safety and feasibility of the RACN system for cardiac navigation. The results demonstrated that RACN performed comparably with manual navigation, with improved precision and consistency for targets located in and near the right atrial chamber. Copyright © 2011 John Wiley & Sons, Ltd.

  8. Very Large Scale Integrated Circuits for Military Systems.

    DTIC Science & Technology

    1981-01-01

    ABBREVIATIONS A/D Analog-to-digital C AGC Automatic Gain Control A A/J Anti-jam ASP Advanced Signal Processor AU Arithmetic Units C.AD Computer-Aided...ESM) equipments (Ref. 23); in lieu of an adequate automatic proces- sing capability, the function is now performed manually (Ref. 24), which involves...a human operator, displays, etc., and a sacrifice in performance (acquisition speed, saturation signal density). Various automatic processing

  9. Acceleration and Performance Modeling Workshop, Washington, DC, 14-17 May 79,

    DTIC Science & Technology

    1979-12-01

    disturbance of the muscular systems, perhaps changes in spindle fiber output, and changes in the perceived weight of the muscle because of the acceleration...at this point either. The output models which are determining performance are essentially tied to muscular systems, through manual control (hand and...feet), and through speech, another muscular output. In normal activities the pilot, who senses changes in the visual system, the acceleration vector

  10. Validation of a Cytotechnologist Manual Counting Service for the Ki67 Index in Neuroendocrine Tumors of the Pancreas and Gastrointestinal Tract.

    PubMed

    Cottenden, Jennielee; Filter, Emily R; Cottreau, Jon; Moore, David; Bullock, Martin; Huang, Weei-Yuarn; Arnason, Thomas

    2018-03-01

    - Pathologists routinely assess Ki67 immunohistochemistry to grade gastrointestinal and pancreatic neuroendocrine tumors. Unfortunately, manual counts of the Ki67 index are very time consuming and eyeball estimation has been criticized as unreliable. Manual Ki67 counts performed by cytotechnologists could potentially save pathologist time and improve accuracy. - To assess the concordance between manual Ki67 index counts performed by cytotechnologists versus eyeball estimates and manual Ki67 counts by pathologists. - One Ki67 immunohistochemical stain was retrieved from each of 18 archived gastrointestinal or pancreatic neuroendocrine tumor resections. We compared pathologists' Ki67 eyeball estimates on glass slides and printed color images with manual counts performed by 3 cytotechnologists and gold standard manual Ki67 index counts by 3 pathologists. - Tumor grade agreement between pathologist image eyeball estimate and gold standard pathologist manual count was fair (κ = 0.31; 95% CI, 0.030-0.60). In 9 of 20 cases (45%), the mean pathologist eyeball estimate was 1 grade higher than the mean pathologist manual count. There was almost perfect agreement in classifying tumor grade between the mean cytotechnologist manual count and the mean pathologist manual count (κ = 0.910; 95% CI, 0.697-1.00). In 20 cases, there was only 1 grade disagreement between the 2 methods. Eyeball estimation by pathologists required less than 1 minute, whereas manual counts by pathologists required a mean of 17 minutes per case. - Eyeball estimation of the Ki67 index has a high rate of tumor grade misclassification compared with manual counting. Cytotechnologist manual counts are accurate and save pathologist time.

  11. Efficacy of manual therapy in the treatment of tension-type headache. A systematic review from 2000-2013.

    PubMed

    Lozano López, C; Mesa Jiménez, J; de la Hoz Aizpurúa, J L; Pareja Grande, J; Fernández de Las Peñas, C

    2016-01-01

    To study the efficacy of manual therapy in the treatment of tension-type headache (TTH) by assessing the quality of randomized control trials (RCTs) published from the year 2000 to April 2013. A search was performed in the following databases: MEDLINE, EBSCO, CINAHL, SCOPUS, PEDRO and OVID. An analysis was made of RCT including patients with TTH receiving any manual therapy, and assessing outcome measures including the intensity, and frequency or duration of the headache. Two independent referees reviewed the methodological quality of RCTs using the Jadad scale. Data from the studies were extracted by two different reviewers. A total of fourteen RCTs were selected. Twelve studies showed acceptable quality (Jadad scale ≥3), and the remaining 2 had low quality (Jadad=2). The studies showed positive results, including reduction in headache intensity and/or frequency, reduction of medication consumption, and improvement in quality of life. The effectiveness of manual therapy for TTH cannot be completely assessed due to the heterogeneity in study design, outcome measures, and different treatments. Nevertheless, the results suggest patients with TTH receiving manual therapies showed better progress than those receiving conventional treatment or placebo. Further studies of high quality using manual therapy protocols, and also including standardized outcome measures, are now needed to clarify the efficacy of manual therapy in the management of TTH. Copyright © 2013 Sociedad Española de Neurología. Publicado por Elsevier España, S.L.U. All rights reserved.

  12. Preliminary clinical evaluation of semi-automated nailfold capillaroscopy in the assessment of patients with Raynaud's phenomenon.

    PubMed

    Murray, Andrea K; Feng, Kaiyan; Moore, Tonia L; Allen, Phillip D; Taylor, Christopher J; Herrick, Ariane L

    2011-08-01

      Nailfold capillaroscopy is well established in screening patients with Raynaud's phenomenon for underlying SSc-spectrum disorders, by identifying abnormal capillaries. Our aim was to compare semi-automatic feature measurement from newly developed software with manual measurements, and determine the degree to which semi-automated data allows disease group classification.   Images from 46 healthy controls, 21 patients with PRP and 49 with SSc were preprocessed, and semi-automated measurements of intercapillary distance and capillary width, tortuosity, and derangement were performed. These were compared with manual measurements. Features were used to classify images into the three subject groups.   Comparison of automatic and manual measures for distance, width, tortuosity, and derangement had correlations of r=0.583, 0.624, 0.495 (p<0.001), and 0.195 (p=0.040). For automatic measures, correlations were found between width and intercapillary distance, r=0.374, and width and tortuosity, r=0.573 (p<0.001). Significant differences between subject groups were found for all features (p<0.002). Overall, 75% of images correctly matched clinical classification using semi-automated features, compared with 71% for manual measurements.   Semi-automatic and manual measurements of distance, width, and tortuosity showed moderate (but statistically significant) correlations. Correlation for derangement was weaker. Semi-automatic measurements are faster than manual measurements. Semi-automatic parameters identify differences between groups, and are as good as manual measurements for between-group classification. © 2011 John Wiley & Sons Ltd.

  13. CONTROL ROOM WITH SPRINKLER SYSTEM CONTROLS, INCLUDING MANUAL CONTROL BOXES ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    CONTROL ROOM WITH SPRINKLER SYSTEM CONTROLS, INCLUDING MANUAL CONTROL BOXES FOR THE VENTILATION SYSTEM AND A PLC SWITCH FOR AUTOMATIC CO (CARBON MONOXIDE) SYSTEM. THE AIR TESTING SYSTEM IS FREE STANDING AND THE FANS ARE COMPUTER-OPERATED. - Alaskan Way Viaduct and Battery Street Tunnel, Seattle, King County, WA

  14. Management of occiput posterior position in the second stage of labor: a survey of midwifery practice in Australia.

    PubMed

    Phipps, Hala; de Vries, Brad; Jagadish, Ujvala; Hyett, Jon

    2014-03-01

    The management of the occiput posterior (OP) position has been controversial for many years. Manual rotation can be performed by midwives and could reduce cesarean sections and instrumental births. We aimed to determine current midwifery views, knowledge, and practice of manual rotation. A de-identified, self-reported questionnaire was e-mailed to all Australian College of Midwives full members (n = 3,997). Of 3,182 surveyed, 57 percent (1,817) responded, of whom 51 percent (920) were currently practicing midwifery. Seventy-seven percent of midwives thought that manual rotation at full dilatation was a valid intervention. Sixty-four percent stated the procedure was acceptable before instrumental delivery, but 30 percent were unsure. Most practicing midwives (93%) had heard of manual rotation, but only 18 percent had performed one in the last year. Midwives would support the routine performance of manual rotation for OP position if it reduced operative births from 68 to 50 percent and would support manual rotation for occiput transverse (OT) position if it reduced operative births from 39 to 25 percent. This study indicates that manual rotation is considered acceptable by most midwives in Australia, yet is only performed by a minority. Midwives would be willing to perform prophylactic manual rotation if it was known to facilitate normal vaginal births suggesting a scope to introduce this procedure into widespread clinical practice. © 2014, Copyright the Authors Journal compilation © 2014, Wiley Periodicals, Inc.

  15. Non-invasive stimulation of the vibrissal pad improves recovery of whisking function after simultaneous lesion of the facial and infraorbital nerves in rats.

    PubMed

    Bendella, H; Pavlov, S P; Grosheva, M; Irintchev, A; Angelova, S K; Merkel, D; Sinis, N; Kaidoglou, K; Skouras, E; Dunlop, S A; Angelov, Doychin N

    2011-07-01

    We have recently shown that manual stimulation of target muscles promotes functional recovery after transection and surgical repair to pure motor nerves (facial: whisking and blink reflex; hypoglossal: tongue position). However, following facial nerve repair, manual stimulation is detrimental if sensory afferent input is eliminated by, e.g., infraorbital nerve extirpation. To further understand the interplay between sensory input and motor recovery, we performed simultaneous cut-and-suture lesions on both the facial and the infraorbital nerves and examined whether stimulation of the sensory afferents from the vibrissae by a forced use would improve motor recovery. The efficacy of 3 treatment paradigms was assessed: removal of the contralateral vibrissae to ensure a maximal use of the ipsilateral ones (vibrissal stimulation; Group 2), manual stimulation of the ipsilateral vibrissal muscles (Group 3), and vibrissal stimulation followed by manual stimulation (Group 4). Data were compared to controls which underwent surgery but did not receive any treatment (Group 1). Four months after surgery, all three treatments significantly improved the amplitude of vibrissal whisking to 30° versus 11° in the controls of Group 1. The three treatments also reduced the degree of polyneuronal innervation of target muscle fibers to 37% versus 58% in Group 1. These findings indicate that forced vibrissal use and manual stimulation, either alone or sequentially, reduce target muscle polyinnervation and improve recovery of whisking function when both the sensory and the motor components of the trigemino-facial system regenerate.

  16. Effects of Static Stretching and Playing Soccer on Knee Laxity.

    PubMed

    Baumgart, Christian; Gokeler, Alli; Donath, Lars; Hoppe, Matthias W; Freiwald, Jürgen

    2015-11-01

    This study investigated exercise-induced effects of static stretching and playing soccer on anterior tibial translation (ATT) of the knee joint. Randomized controlled trial. University biomechanics laboratory. Thirty-one athletes were randomly assigned into a stretching (26.9 ± 6.2 years, 1.77 ± 0.09 m, 67.9 ± 10.7 kg) and a control group (27.9 ± 7.4 years, 1.75 ± 0.08 m, 72.0 ± 14.9 kg). Thirty-one amateur soccer players in an additional soccer group (25.1 ± 5.6 years, 1.74 ± 0.10 m, 71.8 ± 14.8 kg). All participants had no history of knee injury requiring surgery and any previous knee ligament or cartilage injury. The stretching group performed 4 different static stretching exercises with a duration of 2 × 20 seconds interspersed with breaks of 10 seconds. The soccer group completed a 90-minute soccer-specific training program. The control group did not perform any physical activity for approximately 30 minutes. Anterior tibial translation was measured with the KT-1000 knee arthrometer at forces of 67 N, 89 N, and maximal manual force (Max) before and after the intervention. There was a significant increase in ATT after static stretching and playing soccer at all applied forces. Maximal manual testing revealed a mean increase of ATT after static stretching of 2.1 ± 1.6 mm (P < 0.0005) and after playing soccer of 1.0 ± 1.5 mm (P = 0.001). The ATT increase after static stretching at 67 and 89 N is significantly higher than in controls. At maximum manual testing, significant differences were evident between all groups. Static stretching and playing soccer increase ATT and may consequently influence mechanical factors of the anterior cruciate ligament. The ATT increase after static stretching was greater than after playing soccer. The observed increase in ATT after static stretching and playing soccer may be associated with changes in kinesthetic perception and sensorimotor control, activation of muscles, joint stability, overall performance, and higher injury risk.

  17. Manual transmission enhances attention and driving performance of ADHD adolescent males: pilot study.

    PubMed

    Cox, Daniel J; Punja, Mohan; Powers, Katie; Merkel, R Lawrence; Burket, Roger; Moore, Melissa; Thorndike, Frances; Kovatchev, Boris

    2006-11-01

    Inattention is a major contributor to driving mishaps and is especially problematic among adolescent drivers with ADHD, possibly contributing to their 2 to 4 times higher incidence of collisions. Manual transmission has been demonstrated to be associated with greater arousal. This study tests the hypotheses that manual transmission, compared to automatic transmission, would be associated with better attention and performance on a driving simulator. Ten adolescent drivers with ADHD practice driving on the simulator in the manual and automatic mode. Employing a single-blind, cross-over design, participants drive the simulator at 19:30 and 22:30 hr for 30 min in both transmissions and rate their attention to driving. Subjectively, participants report being more attentive while driving in manual transmission mode. Objectively, participants drive safer in the manual transmission mode. Although in need of replication, this pilot study suggests a behavioral intervention to improve driving performance among ADHD adolescents.

  18. Effectiveness of basic display augmentation in vehicular control by visual field cues

    NASA Technical Reports Server (NTRS)

    Grunwald, A. J.; Merhav, S. J.

    1978-01-01

    The paper investigates the effectiveness of different basic display augmentation concepts - fixed reticle, velocity vector, and predicted future vehicle path - for RPVs controlled by a vehicle-mounted TV camera. The task is lateral manual control of a low flying RPV along a straight reference line in the presence of random side gusts. The man-machine system and the visual interface are modeled as a linear time-invariant system. Minimization of a quadratic performance criterion is assumed to underlie the control strategy of a well-trained human operator. The solution for the optimal feedback matrix enables the explicit computation of the variances of lateral deviation and directional error of the vehicle and of the control force that are used as performance measures.

  19. FAA Air Traffic Control Operations Concepts. Volume 4. TAAS (Terminal Advanced Automation System) Terminal Controllers

    DTIC Science & Technology

    1988-07-29

    manually under controller comiand. 40.3.7.1.2.1.1.2-19 b. Ordering - In manual ordering , the 780 controller shall have the capability to put o new FOE...7.1.2.1.1.2-09 a. Posting - This orgonization of FOEs shall 780 be provided at the option of the controller. 40.3.7.1.2.1.1.2-19 b. Ordering - In manual ... ordering , the 780 controller shall have the capability to put o new FOE in the appropriate place in a list and to move FOEs with respect to one another

  20. Manual hyperinflation in airway clearance in pediatric patients: a systematic review

    PubMed Central

    de Godoy, Vanessa Cristina Waetge Pires; Zanetti, Nathalia Mendonça; Johnston, Cíntia

    2013-01-01

    Objective To perform an assessment of the available literature on manual hyperinflation as a respiratory physical therapy technique used in pediatric patients, with the main outcome of achieving airway clearance. Methods We reviewed articles included in the Lilacs (Latin American and Caribbean Literature on Health Sciences/Literatura Latino Americana e do Caribe em Ciências da Saúde), Cochrane Library, Medline (via Virtual Health Library and PubMed), SciELO (Scientific Electronic Library), and PEDro (Physiotherapy Evidence Database) databases from 2002 to 2013 using the following search terms: "physiotherapy (techniques)", "respiratory therapy", "intensive care", and "airway clearance". The selected studies were classified according to the level of evidence and grades of recommendation (method of the Oxford Centre for Evidence-Based Medicine) by two examiners, while a third examiner repeated the search and analysis and checked the classification of the articles. Results Three articles were included for analysis, comprising 250 children (aged 0 to 16 years). The main diagnoses were acute respiratory failure, recovery following heart congenital disease and upper abdominal surgery, bone marrow transplantation, asthma, tracheal reconstruction, brain injury, airway injury, and heterogeneous lung diseases. The studies were classified as having a level of evidence 2C and grade of recommendation C. Conclusions Manual hyperinflation appeared useful for airway clearance in the investigated population, although the evidence available in the literature remains insufficient. Therefore, controlled randomized studies are needed to establish the safety and efficacy of manual hyperinflation in pediatric patients. However, manual hyperinflation must be performed by trained physical therapists only. PMID:24213091

  1. The relationship between cell phone use and management of driver fatigue: It's complicated.

    PubMed

    Saxby, Dyani Juanita; Matthews, Gerald; Neubauer, Catherine

    2017-06-01

    Voice communication may enhance performance during monotonous, potentially fatiguing driving conditions (Atchley & Chan, 2011); however, it is unclear whether safety benefits of conversation are outweighed by costs. The present study tested whether personalized conversations intended to simulate hands-free cell phone conversation may counter objective and subjective fatigue effects elicited by vehicle automation. A passive fatigue state (Desmond & Hancock, 2001), characterized by disengagement from the task, was induced using full vehicle automation prior to drivers resuming full control over the driving simulator. A conversation was initiated shortly after reversion to manual control. During the conversation an emergency event occurred. The fatigue manipulation produced greater task disengagement and slower response to the emergency event, relative to a control condition. Conversation did not mitigate passive fatigue effects; rather, it added worry about matters unrelated to the driving task. Conversation moderately improved vehicle control, as measured by SDLP, but it failed to counter fatigue-induced slowing of braking in response to an emergency event. Finally, conversation appeared to have a hidden danger in that it reduced drivers' insights into performance impairments when in a state of passive fatigue. Automation induced passive fatigue, indicated by loss of task engagement; yet, simulated cell phone conversation did not counter the subjective automation-induced fatigue. Conversation also failed to counter objective loss of performance (slower braking speed) resulting from automation. Cell phone conversation in passive fatigue states may impair drivers' awareness of their performance deficits. Practical applications: Results suggest that conversation, even using a hands-free device, may not be a safe way to reduce fatigue and increase alertness during transitions from automated to manual vehicle control. Copyright © 2017 Elsevier Ltd and National Safety Council. All rights reserved.

  2. Quality control in urinalysis.

    PubMed

    Takubo, T; Tatsumi, N

    1999-01-01

    Quality control (QC) has been introduced in laboratories, and QC surveys in urinalysis have been performed by College of American Pathologist, by Japanese Association of Medical Technologists, by Osaka Medical Association and by manufacturers. QC survey in urinalysis for synthetic urine by the reagent strip and instrument made in same manufacturer, and by an automated urine cell analyser provided satisfactory results among laboratories. QC survey in urinalysis for synthetic urine by the reagent strips and instruments made by various manufacturers indicated differences in the determination values among manufacturers, and between manual and automated methods because the reagent strips and instruments have different characteristics, respectively. QC photo survey in urinalysis on the microscopic photos of urine sediment constituents indicated differences in the identification of cells among laboratories. From the results, it is necessary to standardize a reagent strip method, manual and automated methods, and synthetic urine.

  3. Design of a force reflecting hand controller for space telemanipulation studies

    NASA Technical Reports Server (NTRS)

    Paines, J. D. B.

    1987-01-01

    The potential importance of space telemanipulator systems is reviewed, along with past studies of master-slave manipulation using a generalized force reflecting master arm. Problems concerning their dynamic interaction with the human operator have been revealed in the use of these systems, with marked differences between 1-g and simulated weightless conditions. A study is outlined to investigate the optimization of the man machine dynamics of master-slave manipulation, and a set of specifications is determined for the apparatus necessary to perform this investigation. This apparatus is a one degree of freedom force reflecting hand controller with closed loop servo control which enables it to simulate arbitrary dynamic properties to high bandwidth. Design of the complete system and its performance is discussed. Finally, the experimental adjustment of the hand controller dynamics for smooth manual control performance with good operator force perception is described, resulting in low inertia, viscously damped hand controller dynamics.

  4. Comparison of the Automated cobas u 701 Urine Microscopy and UF-1000i Flow Cytometry Systems and Manual Microscopy in the Examination of Urine Sediments.

    PubMed

    Lee, Wonmok; Ha, Jung-Sook; Ryoo, Nam-Hee

    2016-09-01

    The cobas u 701, a new automated image-based urine sediment analyzer, was introduced recently. In this study, we compared its performance with that of UF-1000i flow cytometry and manual microscopy in the examination of urine sediments. Precision, linearity, and carry-over were determined for the two urine sediment analyzers. For a comparison of the method, 300 urine samples were examined by the automated analyzers and by manual microscopy using a KOVA chamber. Within-run coefficients of variation (CVs) for the control materials were 7.0-8.8% and 1.7-5.7% for the cobas u 701 and UF-1000i systems, respectively. Between-run CVs were 8.5-9.8% and 2.7-5.4%, respectively. Both instruments showed good linearity and negligible carry-over. For red blood cells (RBC), white blood cells (WBC), and epithelial cells (EPI), the overall concordance rates within one grade of difference among the three methods were good (78.6-86.0%, 88.7-93.8%, and 81.3-90.7%, respectively). The concordance rate for casts was poor (66.5-68.9%). Compared with manual microscopy, the two automated sediment analyzers tested in this study showed satisfactory analytical performances for RBC, WBC, and EPI. However, for other urine sediment particles confirmation by visual microscopy is still required. © 2016 Wiley Periodicals, Inc.

  5. Acupuncture and related therapies used as add-on or alternative to prokinetics for functional dyspepsia: overview of systematic reviews and network meta-analysis.

    PubMed

    Ho, Robin S T; Chung, Vincent C H; Wong, Charlene H L; Wu, Justin C Y; Wong, Samuel Y S; Wu, Irene X Y

    2017-09-04

    Prokinetics for functional dyspepsia (FD) have relatively higher number needed to treat values. Acupuncture and related therapies could be used as add-on or alternative. An overview of systematic reviews (SRs) and network meta-analyses (NMA) were performed to evaluate the comparative effectiveness of different acupuncture and related therapies. We conducted a comprehensive literature search for SRs of randomized controlled trials (RCTs) in eight international and Chinese databases. Data from eligible RCTs were extracted for random effect pairwise meta-analyses. NMA was used to explore the most effective treatment among acupuncture and related therapies used alone or as add-on to prokinetics, compared to prokinetics alone. From five SRs, 22 RCTs assessing various acupuncture and related therapies were included. No serious adverse events were reported. Two pairwise meta-analyses showed manual acupuncture has marginally stronger effect in alleviating global FD symptoms, compared to domperidone or itopride. Results from NMA showed combination of manual acupuncture and clebopride has the highest probability in alleviating patient reported global FD symptom. Combination of manual acupuncture and clebopride has the highest probability of being the most effective treatment for FD symptoms. Patients who are contraindicated for prokinetics may use manual acupuncture or moxibustion as alternative. Future confirmatory comparative effectiveness trials should compare clebopride add-on manual acupuncture with domperidone add-on manual acupuncture and moxibustion.

  6. Manual therapy directed at the knee or lumbopelvic region does not influence quadriceps spinal reflex excitability.

    PubMed

    Grindstaff, Terry L; Pietrosimone, Brian G; Sauer, Lindsay D; Kerrigan, D Casey; Patrie, James T; Hertel, Jay; Ingersoll, Christopher D

    2014-08-01

    Manual therapies, directed to the knee and lumbopelvic region, have demonstrated the ability to improve neuromuscular quadriceps function in individuals with knee pathology. It remains unknown if manual therapies may alter impaired spinal reflex excitability, thus identifying a potential mechanism in which manual therapy may improve neuromuscular function following knee injury. To determine the effect of local and distant mobilisation/manipulation interventions on quadriceps spinal reflex excitability. Seventy-five individuals with a history of knee joint injury and current quadriceps inhibition volunteered for this study. Participants were randomised to one of five intervention groups: lumbopelvic manipulation (grade V), lumbopelvic manipulation positioning (no thrust), grade IV patellar mobilisation, grade I patellar mobilisation, and control (no treatment). Changes in spinal reflex excitability were quantified by assessing the Hoffmann reflex (H-reflex), presynaptic, and postsynaptic excitability. A hierarchical linear-mixed model for repeated measures was performed to compare changes in outcome variables between groups over time (pre, post 0, 30, 60, 90 min). There were no significant differences in H-reflex, presynaptic, or postsynaptic excitability between groups across time. Manual therapies directed to the knee or lumbopelvic region did not acutely change quadriceps spinal reflex excitability. Although manual therapies may improve impairments and functional outcomes the underlying mechanism does not appear to be related to changes in spinal reflex excitability. Copyright © 2014 Elsevier Ltd. All rights reserved.

  7. Development of a community pharmacy disaster preparedness manual.

    PubMed

    Noe, Brooke; Smith, April

    2013-01-01

    To share an independent pharmacy's experience creating a practical manual for disaster preparedness that incorporates applicable pharmacy regulations, provides a plan to prepare a community pharmacy for disasters, and addresses the pharmacy's duty to the community during disasters. A literature search was performed to determine if such a manual or a guide had been published previously. The search returned examples of expectations of hospitals during disasters, but few results were specific to community pharmacy. An Internet search for pharmacy contingency planning returned only a few checklists and descriptive reports of pharmacist involvement in past disasters. Public resources available from the Centers for Disease Control and Prevention, Environmental Protection Agency, Drug Enforcement Administration, Department of Public Health, Federal Emergency Management Agency, National Community Pharmacists Association, and American Pharmacists Association were explored. The Iowa State Board of Pharmacy also was contacted. Information was compiled to create a useful guide that addressed disaster planning, risk assessment, and public need during a disaster and that prioritized the needs of the pharmacy and community. Every community pharmacy should have a detailed disaster preparedness manual that is readily accessible and easy to follow. The manual created for Valley Drug focused on continuing pharmacy operations while minimizing disruptions in patient care during a disaster. Our manual included only necessary information required to prepare for, operate during, or recover from a disaster.

  8. A novel system for automated propofol sedation: hybrid sedation system (HSS).

    PubMed

    Zaouter, Cedrick; Taddei, Riccardo; Wehbe, Mohamad; Arbeid, Erik; Cyr, Shantale; Giunta, Francesco; Hemmerling, Thomas M

    2017-04-01

    Closed-loop systems for propofol have been demonstrated to be safe and reliable for general anesthesia. However, no study has been conducted using a closed-loop system specifically designed for sedation in patients under spinal anesthesia. We developed an automatic anesthesia sedation system that allows for closed-loop delivery of propofol for sedation integrating a decision support system, called the hybrid sedation system (HSS). The objective of this study is to compare this system with standard practice. One hundred fifty patients were enrolled and randomly assigned to two groups: HSS-Group (N = 75), in which propofol was administered using a closed-loop system; Control Group (N = 75), in which propofol was delivered manually. The clinical performance of the propofol sedation control is defined as efficacy to maintain bispectral index (BIS) near 65. The clinical control was called 'Excellent', 'Good', 'Poor' and 'Inadequate' with BIS values within 10 %, from 11 to 20 %, 21 to 30 %, or greater than 30 % of the BIS target of 65, respectively. The controller performance was evaluated using Varvel's parameters. Data are presented as mean ± standard deviation, groups were compared using t test or Chi square test, P < 0.05. Clinical performance of sedation showed 'Excellent' control in the HSS-group for a significantly longer period of time (49 vs. 26 % in the control group, P < 0.0001). 'Poor' and 'Inadequate' sedation was significantly shorter in the HSS Group compared to the Control Group (11 and 10 % vs. 20 and 18 %, respectively, P < 0.0001). The novel, closed-loop system for propofol sedation showed better maintenance of the target BIS value compared to manual administration.

  9. Performance Improvement of Friction Stir Welds by Better Surface Finish

    NASA Technical Reports Server (NTRS)

    Russell, Sam; Nettles, Mindy

    2015-01-01

    The as-welded friction stir weld has a cross section that may act as a stress concentrator. The geometry associated with the stress concentration may reduce the weld strength and it makes the weld challenging to inspect with ultrasound. In some cases, the geometry leads to false positive nondestructive evaluation (NDE) indications and, in many cases, it requires manual blending to facilitate the inspection. This study will measure the stress concentration effect and develop an improved phased array ultrasound testing (PAUT) technique for friction stir welding. Post-welding, the friction stir weld (FSW) tool would be fitted with an end mill that would machine the weld smooth, trimmed shaved. This would eliminate the need for manual weld preparation for ultrasonic inspections. Manual surface preparation is a hand operation that varies widely depending on the person preparing the welds. Shaving is a process that can be automated and tightly controlled.

  10. 46 CFR 62.10-1 - Definitions.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... control means a function of an automatic control system to restrict operation to a specified operating... automatic or manual control. Safety trip control system means a manually or automatically operated system... GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) MARINE ENGINEERING VITAL SYSTEM AUTOMATION Terms Used...

  11. 46 CFR 62.10-1 - Definitions.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... control means a function of an automatic control system to restrict operation to a specified operating... automatic or manual control. Safety trip control system means a manually or automatically operated system... GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) MARINE ENGINEERING VITAL SYSTEM AUTOMATION Terms Used...

  12. 46 CFR 62.10-1 - Definitions.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... control means a function of an automatic control system to restrict operation to a specified operating... automatic or manual control. Safety trip control system means a manually or automatically operated system... GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) MARINE ENGINEERING VITAL SYSTEM AUTOMATION Terms Used...

  13. 46 CFR 62.10-1 - Definitions.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... control means a function of an automatic control system to restrict operation to a specified operating... automatic or manual control. Safety trip control system means a manually or automatically operated system... GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) MARINE ENGINEERING VITAL SYSTEM AUTOMATION Terms Used...

  14. 46 CFR 62.10-1 - Definitions.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... control means a function of an automatic control system to restrict operation to a specified operating... automatic or manual control. Safety trip control system means a manually or automatically operated system... GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) MARINE ENGINEERING VITAL SYSTEM AUTOMATION Terms Used...

  15. Microbial ecology laboratory procedures manual NASA/MSFC

    NASA Technical Reports Server (NTRS)

    Huff, Timothy L.

    1990-01-01

    An essential part of the efficient operation of any microbiology laboratory involved in sample analysis is a standard procedures manual. The purpose of this manual is to provide concise and well defined instructions on routine technical procedures involving sample analysis and methods for monitoring and maintaining quality control within the laboratory. Of equal importance is the safe operation of the laboratory. This manual outlines detailed procedures to be followed in the microbial ecology laboratory to assure safety, analytical control, and validity of results.

  16. The effectiveness of manual therapy in treating cervicogenic dizziness: a systematic review.

    PubMed

    Yaseen, Khalid; Hendrick, Paul; Ismail, Ayah; Felemban, Mohannad; Alshehri, Mansour Abdullah

    2018-01-01

    [Purpose] This review provides an evaluation of the evidence for the effectiveness of using manual therapy to treat cervicogenic dizziness. [Subjects and Methods] The literature was systematically searched on the May 2, 2016 using the following online databases: Medline, EMBASE, CINAHL and PEDro. This review included randomised controlled trials and compared the efficacy of manual therapy for the treatment of cervicogenic dizziness, compared to other types of intervention. This study measured changes based on dizziness intensity and frequency. [Results] The primary search found 30 articles, but only four articles met the inclusion criteria. Assessment of methodological quality was performed by two researchers using the PEDro scale. The level of evidence was determined using a recognised grading scale. Three out of the four articles were deemed to have high methodological quality, while the fourth was rated as moderate quality. The attributed level of evidence was moderate (level 2). [Conclusion] Manual therapy is potentially effective for managing cervicogenic dizziness. However, due to the heterogeneity of the results and techniques and the low number of studies, further research is recommended to provide conclusive evidence.

  17. Solar heating and cooling system installed at RKL Controls Company, Lumberton, New Jersey

    NASA Technical Reports Server (NTRS)

    1981-01-01

    The final results of the design and operation of a computer controlled solar heated and cooled 40,000 square foot manufacturing building, sales office, and computer control center/display room are summarized. The system description, test data, major problems and resolutions, performance, operation and maintenance manual, equipment manufacturers' literature, and as-built drawings are presented. The solar system is composed of 6,000 square feet of flat plate collectors, external above ground storage subsystem, controls, absorption chiller, heat recovery, and a cooling tower.

  18. Entry dynamics of space shuttle orbiter with longitudinal stability and control uncertainties at supersonic and hypersonic speeds

    NASA Technical Reports Server (NTRS)

    Stone, H. W.; Powell, R. W.

    1977-01-01

    A six-degree-of-freedom simulation analysis was conducted to examine the effects of longitudinal static aerodynamic stability and control uncertainties on the performance of the space shuttle orbiter automatic (no manual inputs) entry guidance and control systems. To establish the acceptable boundaries, the static aerodynamic characteristics were varied either by applying a multiplier to the aerodynamic parameter or by adding an increment. With either of two previously identified control system modifications included, the acceptable longitudinal aerodynamic boundaries were determined.

  19. 14 CFR 33.87 - Endurance test.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... particular engine being tested. (2) Any automatic engine control that is part of the engine must control the engine during the endurance test except for operations where automatic control is normally overridden by manual control or where manual control is otherwise specified for a particular test run. (3) Except as...

  20. 14 CFR 33.87 - Endurance test.

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... particular engine being tested. (2) Any automatic engine control that is part of the engine must control the engine during the endurance test except for operations where automatic control is normally overridden by manual control or where manual control is otherwise specified for a particular test run. (3) Except as...

  1. Twenty-First Annual Conference on Manual Control

    NASA Technical Reports Server (NTRS)

    Miller, R. A. (Compiler); Jagacinski, R. J. (Compiler)

    1986-01-01

    The proceedings of the entitled conference are presented. Twenty-nine manuscripts and eight abstracts pertaining to workload, attention and errors, controller evaluation, movement skills, coordination and decision making, display evaluation and human operator modeling and manual control.

  2. Optimal cooperative control synthesis of active displays

    NASA Technical Reports Server (NTRS)

    Garg, S.; Schmidt, D. K.

    1985-01-01

    A technique is developed that is intended to provide a systematic approach to synthesizing display augmentation for optimal manual control in complex, closed-loop tasks. A cooperative control synthesis technique, previously developed to design pilot-optimal control augmentation for the plant, is extended to incorporate the simultaneous design of performance enhancing displays. The technique utilizes an optimal control model of the man in the loop. It is applied to the design of a quickening control law for a display and a simple K/s(2) plant, and then to an F-15 type aircraft in a multi-channel task. Utilizing the closed loop modeling and analysis procedures, the results from the display design algorithm are evaluated and an analytical validation is performed. Experimental validation is recommended for future efforts.

  3. METRO-APEX Volume 7.1: Air Pollution Control Officer's Manual. Revised.

    ERIC Educational Resources Information Center

    University of Southern California, Los Angeles. COMEX Research Project.

    The Air Pollution Control Officer's Manual is one of a set of twenty-one manuals used in METRO-APEX 1974, a computerized college and professional level, computer-supported, role-play, simulation exercise of a community with "normal" problems. Stress is placed on environmental quality considerations. APEX 1974 is an expansion of APEX--Air…

  4. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Singledecker, Amalia

    Lockout/tagout (LO/TO) is used to disable machinery or equipment and to control potentially hazardous energy while service or maintenance is being performed. This course is designed to introduce trainees to the Los Alamos National Laboratory (LANL) procedure for the lockout and tagout of hazardous energy. Trainees will apply their knowledge in two exercises located at the end of the course manual.

  5. 40 CFR 60.453 - Performance test and compliance provisions.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ....45 Manual electrostatic spray 0.60 Flow coat 0.85 Dip coat 0.85 Nonrotational automatic electrostatic... applied (G) during the calendar month for each affected facility by the following equation: EC16NO91.038... affected facility that uses a capture system and a control device that destroys VOC's (e.g., incinerator...

  6. Developmental Changes in Motor Control: Insights from Bimanual Coordination

    ERIC Educational Resources Information Center

    Serrien, Deborah J.; Sovijärvi-Spapé, Michiel M.; Rana, Gita

    2014-01-01

    Manual dexterity is known to gradually progress with developmental age. In this study, we evaluate the performance of unimanual and bimanual actions under perturbed and unperturbed conditions in children between 4 and 10 years of age. Behavior was assessed by means of trajectory measurements and degree of bimanual coupling. The results showed that…

  7. MRI features after radiofrequency ablation of osteoid osteoma with cooled probes and impedance-control energy delivery.

    PubMed

    Cantwell, Colin P; Kerr, Jennifer; O'Byrne, John; Eustace, Stephen

    2006-05-01

    The purposes of our study were to determine the temporal changes in MR signal in bone after radiofrequency ablation of osteoid osteoma and the size of the zone of marrow signal change produced by the radiofrequency technique and to compare the size of the zone with published data for radiofrequency ablation with manual-control protocols. Radiofrequency ablation was performed in 10 patients with a clinical and radiologic diagnosis of osteoid osteoma. A cooled radiofrequency probe was inserted in the nidus. Twelve minutes of radiofrequency energy was applied from a 200-W radiofrequency generator in an impedance-control setting. MRI with multiplanar turbo spin-echo T1-weighted and STIR sequences was performed at 1, 7, and 28 days after the procedure in seven patients. The three remaining patients had follow-up imaging at 28 days only. The images were reviewed by two radiologists who categorized the imaging features and measured the marrow zone of signal alteration when visible. The size of the zone of marrow signal change produced by the radiofrequency technique was compared with published data for radiofrequency ablation with manual-control protocols. A 1-mm band of homogeneous altered marrow signal distributed symmetrically parallel to the entire probe tract was seen earliest, at 1 day, in the femoral neck lesion treated with the 2-cm probe. The band was low signal on the T1 sequence and high signal on the STIR sequence, and the diameter of the zone was 27 mm. By 7 days, five of the seven treated bones showed a band of marrow signal alteration. By 28 days, all 10 treated bones had a band of marrow signal alteration. The interband distance at 90 degrees to the probe measured on STIR images at 28 days was a mean of 20.9 mm (confidence interval, 16.1-25.7 mm [p < 0.05]; range +/- measurement error, 10.5-35 +/- 1.64 mm) with a 1-cm probe and 30.5 mm (measurement error, +/- 0.78 mm) on T1 images without contrast material when a 2-cm exposed-tip probe was used. Higher-output generators with impedance-control software and internally cooled radiofrequency probes with longer exposed tips produce larger zones of marrow signal change than expected with manual-control protocols. MRI allows detection of temporal marrow signal change after radiofrequency ablation. The marrow signal change with a high-energy delivery protocol is larger than manual-control protocols.

  8. Orion Capsule Handling Qualities for Atmospheric Entry

    NASA Technical Reports Server (NTRS)

    Tigges, Michael A.; Bihari, Brian D.; Stephens, John-Paul; Vos, Gordon A.; Bilimoria, Karl D.; Mueller, Eric R.; Law, Howard G.; Johnson, Wyatt; Bailey, Randall E.; Jackson, Bruce

    2011-01-01

    Two piloted simulations were conducted at NASA's Johnson Space Center using the Cooper-Harper scale to study the handling qualities of the Orion Command Module capsule during atmospheric entry flight. The simulations were conducted using high fidelity 6-DOF simulators for Lunar Return Skip Entry and International Space Station Return Direct Entry flight using bank angle steering commands generated by either the Primary (PredGuid) or Backup (PLM) guidance algorithms. For both evaluations, manual control of bank angle began after descending through Entry Interface into the atmosphere until drogue chutes deployment. Pilots were able to use defined bank management and reversal criteria to accurately track the bank angle commands, and stay within flight performance metrics of landing accuracy, g-loads, and propellant consumption, suggesting that the pilotability of Orion under manual control is both achievable and provides adequate trajectory performance with acceptable levels of pilot effort. Another significant result of these analyses is the applicability of flying a complex entry task under high speed entry flight conditions relevant to the next generation Multi Purpose Crew Vehicle return from Mars and Near Earth Objects.

  9. Automated T2 relaxometry of the hippocampus for temporal lobe epilepsy.

    PubMed

    Winston, Gavin P; Vos, Sjoerd B; Burdett, Jane L; Cardoso, M Jorge; Ourselin, Sebastien; Duncan, John S

    2017-09-01

    Hippocampal sclerosis (HS), the most common cause of refractory temporal lobe epilepsy, is associated with hippocampal volume loss and increased T2 signal. These can be identified on quantitative imaging with hippocampal volumetry and T2 relaxometry. Although hippocampal segmentation for volumetry has been automated, T2 relaxometry currently involves subjective and time-consuming manual delineation of regions of interest. In this work, we develop and validate an automated technique for hippocampal T2 relaxometry. Fifty patients with unilateral or bilateral HS and 50 healthy controls underwent T 1 -weighted and dual-echo fast recovery fast spin echo scans. Hippocampi were automatically segmented using a multi-atlas-based segmentation algorithm (STEPS) and a template database. Voxelwise T2 maps were determined using a monoexponential fit. The hippocampal segmentations were registered to the T2 maps and eroded to reduce partial volume effect. Voxels with T2 >170 msec excluded to minimize cerebrospinal fluid (CSF) contamination. Manual determination of T2 values was performed twice in each subject. Twenty controls underwent repeat scans to assess interscan reproducibility. Hippocampal T2 values were reliably determined using the automated method. There was a significant ipsilateral increase in T2 values in HS (p < 0.001), and a smaller but significant contralateral increase. The combination of hippocampal volumes and T2 values separated the groups well. There was a strong correlation between automated and manual methods for hippocampal T2 measurement (0.917 left, 0.896 right, both p < 0.001). Interscan reproducibility was superior for automated compared to manual measurements. Automated hippocampal segmentation can be reliably extended to the determination of hippocampal T2 values, and a combination of hippocampal volumes and T2 values can separate subjects with HS from healthy controls. There is good agreement with manual measurements, and the technique is more reproducible on repeat scans than manual measurement. This protocol can be readily introduced into a clinical workflow for the assessment of patients with focal epilepsy. © 2017 The Authors. Epilepsia published by Wiley Periodicals, Inc. on behalf of International League Against Epilepsy.

  10. Impact of robotics and a suspended lead suit on physician radiation exposure during percutaneous coronary intervention.

    PubMed

    Madder, Ryan D; VanOosterhout, Stacie; Mulder, Abbey; Elmore, Matthew; Campbell, Jessica; Borgman, Andrew; Parker, Jessica; Wohns, David

    Reports of left-sided brain malignancies among interventional cardiologists have heightened concerns regarding physician radiation exposure. This study evaluated the impact of a suspended lead suit and robotic system on physician radiation exposure during percutaneous coronary intervention (PCI). Real-time radiation exposure data were prospectively collected from dosimeters worn by operating physicians at the head- and chest-level during consecutive PCI cases. Exposures were compared in three study groups: 1) manual PCI performed with traditional lead apparel; 2) manual PCI performed using suspended lead; and 3) robotic PCI performed in combination with suspended lead. Among 336 cases (86.6% manual, 13.4% robotic) performed over 30weeks, use of suspended lead during manual PCI was associated with significantly less radiation exposure to the chest and head of operating physicians than traditional lead apparel (chest: 0.0 [0.1] μSv vs 0.4 [4.0] μSv, p<0.001; head: 0.5 [1.9] μSv vs 14.9 [51.5] μSv, p<0.001). Chest-level radiation exposure during robotic PCI performed in combination with suspended lead was 0.0 [0.0] μSv, which was significantly less chest exposure than manual PCI performed with traditional lead (p<0.001) or suspended lead (p=0.046). In robotic PCI the median head-level exposure was 0.1 [0.2] μSv, which was 99.3% less than manual PCI performed with traditional lead (p<0.001) and 80.0% less than manual PCI performed with suspended lead (p<0.001). Utilization of suspended lead and robotics were observed to result in significantly less radiation exposure to the chest and head of operating physicians during PCI. Copyright © 2016 Elsevier Inc. All rights reserved.

  11. Depth Cue Integration in an Active Control Paradigm

    NASA Technical Reports Server (NTRS)

    Kaiser, Mary K.; Sweet, Barabara T.; Shafto, Meredith; Null, Cynthia H. (Technical Monitor)

    1995-01-01

    Numerous models of depth cue integration have been proposed. Of particular interest is how the visual system processes discrepent cues, as might arise when viewing synthetic displays. A powerful paradigm for examining this integration process can be adapted from manual control research. This methodology introduces independent disturbances in the candidate cues, then performs spectral analysis of subjects' resulting motoric responses (e.g., depth matching). We will describe this technique and present initial findings.

  12. Electromechanical flight control actuator, volume 2

    NASA Technical Reports Server (NTRS)

    1978-01-01

    Schematic diagrams are given for both the four-channel electromechanical actuator and the single-channel power electronics breadboard. Detailed design data is also given on the gears used in the differential gearbox and a copy of the operations manual for the system is included. Performance test results are given for the EMA motor and its current source indicator, the drive control electronics, and the overall system. The power converter waveform test results are also summarized.

  13. Automated search of control points in surface-based morphometry.

    PubMed

    Canna, Antonietta; Russo, Andrea G; Ponticorvo, Sara; Manara, Renzo; Pepino, Alessandro; Sansone, Mario; Di Salle, Francesco; Esposito, Fabrizio

    2018-04-16

    Cortical surface-based morphometry is based on a semi-automated analysis of structural MRI images. In FreeSurfer, a widespread tool for surface-based analyses, a visual check of gray-white matter borders is followed by the manual placement of control points to drive the topological correction (editing) of segmented data. A novel algorithm combining radial sampling and machine learning is presented for the automated control point search (ACPS). Four data sets with 3 T MRI structural images were used for ACPS validation, including raw data acquired twice in 36 healthy subjects and both raw and FreeSurfer preprocessed data of 125 healthy subjects from public databases. The unedited data from a subgroup of subjects were submitted to manual control point search and editing. The ACPS algorithm was trained on manual control points and tested on new (unseen) unedited data. Cortical thickness (CT) and fractal dimensionality (FD) were estimated in three data sets by reconstructing surfaces from both unedited and edited data, and the effects of editing were compared between manual and automated editing and versus no editing. The ACPS-based editing improved the surface reconstructions similarly to manual editing. Compared to no editing, ACPS-based and manual editing significantly reduced CT and FD in consistent regions across different data sets. Despite the extra processing of control point driven reconstructions, CT and FD estimates were highly reproducible in almost all cortical regions, albeit some problematic regions (e.g. entorhinal cortex) may benefit from different editing. The use of control points improves the surface reconstruction and the ACPS algorithm can automate their search reducing the burden of manual editing. Copyright © 2018 Elsevier Inc. All rights reserved.

  14. Closed-loop, pilot/vehicle analysis of the approach and landing task

    NASA Technical Reports Server (NTRS)

    Schmidt, D. K.; Anderson, M. R.

    1985-01-01

    Optimal-control-theoretic modeling and frequency-domain analysis is the methodology proposed to evaluate analytically the handling qualities of higher-order manually controlled dynamic systems. Fundamental to the methodology is evaluating the interplay between pilot workload and closed-loop pilot/vehicle performance and stability robustness. The model-based metric for pilot workload is the required pilot phase compensation. Pilot/vehicle performance and loop stability is then evaluated using frequency-domain techniques. When these techniques were applied to the flight-test data for thirty-two highly-augmented fighter configurations, strong correlation was obtained between the analytical and experimental results.

  15. Effects of Rifle Handling, Target Acquisition, and Trigger Control on Simulated Shooting Performance

    DTIC Science & Technology

    2014-05-06

    qualification task, and covers all of the training requirements listed in the Soldier’s Manual of Common Tasks: Warrior Skills Level 1 handbook...allow for more direct and standardized training based on common Soldier errors. If discernible patterns in these core elements of marksmanship were...more than 50 percent of variance in marksmanship performance on a standard EST weapons qualification task for participants whose 3 Snellen acuity

  16. The Effect of Pain on Task Performance: A Review of the Literature.

    DTIC Science & Technology

    1992-07-01

    Pharmacology. 11 (2), 123-127 (1989) 8. J. D. Benson, Application of manual handling task in the control of low back pain. In Trends in Ergonomics /Human...Factors IV. Proceedings of the Annual International Industrial Ergonomics and Safety Conference. Amsterdam: Elsevier Science Publishers (1987). 9. T...development of a motor performance method for the measurement of pain. Ergonomics . 32 (3), 307-316 (1989) 67. K. Sedlak, Low-back pain perception and

  17. 21 CFR 892.5650 - Manual radionuclide applicator system.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... system. (a) Identification. A manual radionuclide applicator system is a manually operated device... 21 Food and Drugs 8 2013-04-01 2013-04-01 false Manual radionuclide applicator system. 892.5650... planning computer programs, and accessories. (b) Classification. Class I (general controls). The device is...

  18. 21 CFR 892.5650 - Manual radionuclide applicator system.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... system. (a) Identification. A manual radionuclide applicator system is a manually operated device... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Manual radionuclide applicator system. 892.5650... planning computer programs, and accessories. (b) Classification. Class I (general controls). The device is...

  19. 21 CFR 892.5650 - Manual radionuclide applicator system.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... system. (a) Identification. A manual radionuclide applicator system is a manually operated device... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Manual radionuclide applicator system. 892.5650... planning computer programs, and accessories. (b) Classification. Class I (general controls). The device is...

  20. 21 CFR 892.5650 - Manual radionuclide applicator system.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... system. (a) Identification. A manual radionuclide applicator system is a manually operated device... 21 Food and Drugs 8 2014-04-01 2014-04-01 false Manual radionuclide applicator system. 892.5650... planning computer programs, and accessories. (b) Classification. Class I (general controls). The device is...

  1. 21 CFR 892.5650 - Manual radionuclide applicator system.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... system. (a) Identification. A manual radionuclide applicator system is a manually operated device... 21 Food and Drugs 8 2012-04-01 2012-04-01 false Manual radionuclide applicator system. 892.5650... planning computer programs, and accessories. (b) Classification. Class I (general controls). The device is...

  2. Manual Therapy, Therapeutic Patient Education, and Therapeutic Exercise, an Effective Multimodal Treatment of Nonspecific Chronic Neck Pain: A Randomized Controlled Trial.

    PubMed

    Beltran-Alacreu, Hector; López-de-Uralde-Villanueva, Ibai; Fernández-Carnero, Josué; La Touche, Roy

    2015-10-01

    The aim of this study was to determine the effectiveness of a multimodal treatment in the short and medium term for disability in nonspecific chronic neck pain. The design of this study is a single-blinded randomized controlled trial carried out in a university research laboratory. Forty-five patients between 18 and 65 yrs with nonspecific chronic neck pain were included in this study. Each patient was treated eight times over a 4-wk period. The sample was divided into three groups: control group, subjected to a protocol of manual therapy; experimental group 1, subjected to a protocol of manual therapy and therapeutic patient education; and experimental group 2, subjected to manual therapy, therapeutic patient education, and a therapeutic exercise protocol. Assessments were performed at baseline and at 4, 8, and 16 wks using the following measurements: the Neck Disability Index, the 11-item Tampa Scale of Kinesiophobia, the Fear Avoidance Beliefs Questionnaire, the Neck Flexor Muscle Endurance Test, and the Visual Analog Fatigue Scale. The nonparametric Kruskal-Wallis test for the Neck Disability Index showed statistically significant differences between baseline outcomes and all follow-up periods (P < 0.01). In the Kruskal-Wallis test, differences were found for the Visual Analog Fatigue Scale and the Neck Flexor Muscle Endurance Test in the follow-ups at 8 and 16 wks (P < 0.05). Analysis of variance for group × time interaction showed statistically significant changes (Tampa Scale of Kinesiophobia, F = 3.613, P = 0.005; Fear Avoidance Beliefs Questionnaire, F = 2.803, P = 0.022). Minimal detectable changes were obtained in both experimental groups for the 11-item Tampa Scale of Kinesiophobia but not in the control group. Differences between experimental groups and the control group were found in the short and medium term. A multimodal treatment is a good method for reducing disability in patients with nonspecific chronic neck pain in the short and medium term.

  3. Day Care Infection Control Protocol.

    ERIC Educational Resources Information Center

    Seattle-King County Dept. of Public Health, Seattle, WA.

    This day care infection control manual was assembled to provide technical guidance for the prevention and control of communicable diseases to child day care facilities in Seattle and King County, Washington. For each disease, the manual provides background information, public health control recommendations, and letters that can be used to…

  4. Microprocessor-controlled hemodynamics: a step towards improved efficiency and safety.

    PubMed

    Keogh, B E; Jacobs, J; Royston, D; Taylor, K M

    1989-02-01

    Manual titration of sodium nitroprusside (SNP) is widely used for treatment of hypertension following cardiac surgery. This study compared conventional manual control with control by a research prototype of an automatic infusion module based on a proportional plus integral plus derivative (PID) negative feedback loop. Two groups of coronary artery bypass patients requiring SNP for postoperative hypertension were studied prospectively. In the first group, hypertension was controlled by manual adjustment of the SNP infusion rate, and in the second, the infusion rate was controlled automatically. The actual and desired mean arterial pressures (MAP) over consecutive ten-second epochs were recorded during the period of infusion. The MAP was maintained within 10% of the desired MAP 45.8% of the time in the manual group, compared with 90.0% in the automatic group, and the mean percent error in the automatic group was significantly less than in the manual group (P less than 0.01). It is concluded that adoption of such systems will result in improved patient safety and may facilitate more effective distribution of nursing staff within intensive care units.

  5. 14 CFR 23.1587 - Performance information.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... 14 Aeronautics and Space 1 2011-01-01 2011-01-01 false Performance information. 23.1587 Section 23... Information Airplane Flight Manual and Approved Manual Material § 23.1587 Performance information. Unless otherwise prescribed, performance information must be provided over the altitude and temperature ranges...

  6. 14 CFR 23.1587 - Performance information.

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... 14 Aeronautics and Space 1 2013-01-01 2013-01-01 false Performance information. 23.1587 Section 23... Information Airplane Flight Manual and Approved Manual Material § 23.1587 Performance information. Unless otherwise prescribed, performance information must be provided over the altitude and temperature ranges...

  7. 14 CFR 23.1587 - Performance information.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... 14 Aeronautics and Space 1 2010-01-01 2010-01-01 false Performance information. 23.1587 Section 23... Information Airplane Flight Manual and Approved Manual Material § 23.1587 Performance information. Unless otherwise prescribed, performance information must be provided over the altitude and temperature ranges...

  8. Development of a microprocessor controller for stand-alone photovoltaic power systems

    NASA Technical Reports Server (NTRS)

    Millner, A. R.; Kaufman, D. L.

    1984-01-01

    A controller for stand-alone photovoltaic systems has been developed using a low power CMOS microprocessor. It performs battery state of charge estimation, array control, load management, instrumentation, automatic testing, and communications functions. Array control options are sequential subarray switching and maximum power control. A calculator keypad and LCD display provides manual control, fault diagnosis and digital multimeter functions. An RS-232 port provides data logging or remote control capability. A prototype 5 kW unit has been built and tested successfully. The controller is expected to be useful in village photovoltaic power systems, large solar water pumping installations, and other battery management applications.

  9. Semi-manual mastoidectomy assisted by human-robot collaborative control - A temporal bone replica study.

    PubMed

    Lim, Hoon; Matsumoto, Nozomu; Cho, Byunghyun; Hong, Jaesung; Yamashita, Makoto; Hashizume, Makoto; Yi, Byung-Ju

    2016-04-01

    To develop an otological robot that can protect important organs from being injured. We developed a five degree-of-freedom robot for otological surgery. Unlike the other robots that were reported previously, our robot does not replace surgeon's procedures, but instead utilizes human-robot collaborative control. The robot basically releases all of the actuators so that the surgeon can manipulate the drill within the robot's working area with minimal restriction. When the drill reaches a forbidden area, the surgeon feels as if the drill hits a wall. When an engineer performed mastoidectomy using the robot for assistance, the facial nerve in the segmented region was always protected with a more than 2.5mm margin, which was almost the same as the pre-set safety margin of 3mm. Semi-manual drilling using human-robot collaborative control was feasible, and may hold a realistic prospect of clinical use in the near future. Copyright © 2015 Elsevier Ireland Ltd. All rights reserved.

  10. No reduction of manual removal after misoprostol for retained placenta: a double-blind, randomized trial.

    PubMed

    van Stralen, Giel; Veenhof, Marieke; Holleboom, Cas; van Roosmalen, Jos

    2013-04-01

    To test the effect of 800 μg of misoprostol orally on the prevention of manual removal of retained placenta. Multicenter, double-blinded, placebo-controlled, randomized trial. One university and one non-university teaching hospital in the Netherlands. 99 women with retained placenta (longer than 60 min after childbirth) in the absence of postpartum hemorrhage. Eligible women were administered either 800 μg of misoprostol or placebo orally. Number of manual removals of retained placenta and amount of blood loss. Manual removal of retained placenta was performed in 50% of the women who received misoprostol and in 55% who received placebo (relative risk 0.91, 95% confidence interval 0.62-1.34). No difference in the amount of blood loss (970 vs. 1120 mL; p = 0.34) was observed between the two groups. Administration of 800 μg of oral misoprostol, one hour after childbirth, does not seem to reduce the number of manual removals of retained placentas. The time elapsing results in the delivery of 50% of the retained placentas at the expense of an increased risk of postpartum hemorrhage. © 2013 The Authors Acta Obstetricia et Gynecologica Scandinavica © 2013 Nordic Federation of Societies of Obstetrics and Gynecology.

  11. Comparison of the cleaning capacity of Mtwo and Pro Taper rotary systems and manual instruments in primary teeth

    PubMed Central

    Azar, Mohammad Reza; Safi, Laya; Nikaein, Afshin

    2012-01-01

    Background: Root canal cleaning is an important step in endodontic therapy. In order to develop better techniques, a new generation of endodontic instruments has been designed. The aim of this study was to compare the effectiveness of manual K-files (Mani Co, Tokyo, Japan) and two rotary systems–Mtwo (Dentsply-Maillefer, Ballaigues, Switzerland) and ProTaper (VDW, Munich, Germany)–for root canal preparation in primary molars. Materials and Methods: India ink was injected to 160 mesiobuccal and distal root canals of mandibular primary molars. The teeth were randomly divided into three experimental groups and one control group. In each experimental group, either manual instruments (K-files) or rotary instruments (Mtwo or ProTaper) were used to prepare root canals. After cleaning the canals and clearing the teeth, ink removal was evaluated with a stereomicroscope. Statistical analysis was done with Kruskal–Wallis and Friedman tests. Results: There were no significant differences in cleaning efficiency between manual and rotary instruments. Only ProTaper files performed significantly better in the coronal and middle thirds than in the apical third of the root canal. Conclusion: Manual K-files and the Mtwo and ProTaper rotary systems showed equally acceptable cleaning ability in primary molar root canals. PMID:22623929

  12. Voxel-based Gaussian naïve Bayes classification of ischemic stroke lesions in individual T1-weighted MRI scans.

    PubMed

    Griffis, Joseph C; Allendorfer, Jane B; Szaflarski, Jerzy P

    2016-01-15

    Manual lesion delineation by an expert is the standard for lesion identification in MRI scans, but it is time-consuming and can introduce subjective bias. Alternative methods often require multi-modal MRI data, user interaction, scans from a control population, and/or arbitrary statistical thresholding. We present an approach for automatically identifying stroke lesions in individual T1-weighted MRI scans using naïve Bayes classification. Probabilistic tissue segmentation and image algebra were used to create feature maps encoding information about missing and abnormal tissue. Leave-one-case-out training and cross-validation was used to obtain out-of-sample predictions for each of 30 cases with left hemisphere stroke lesions. Our method correctly predicted lesion locations for 30/30 un-trained cases. Post-processing with smoothing (8mm FWHM) and cluster-extent thresholding (100 voxels) was found to improve performance. Quantitative evaluations of post-processed out-of-sample predictions on 30 cases revealed high spatial overlap (mean Dice similarity coefficient=0.66) and volume agreement (mean percent volume difference=28.91; Pearson's r=0.97) with manual lesion delineations. Our automated approach agrees with manual tracing. It provides an alternative to automated methods that require multi-modal MRI data, additional control scans, or user interaction to achieve optimal performance. Our fully trained classifier has applications in neuroimaging and clinical contexts. Copyright © 2015 Elsevier B.V. All rights reserved.

  13. 76 FR 54156 - National Standards for Traffic Control Devices; the Manual on Uniform Traffic Control Devices for...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-08-31

    ... traffic control device design, location, or operation that have made some existing devices in the field...-2010-0159] RIN 2125-AF43 National Standards for Traffic Control Devices; the Manual on Uniform Traffic Control Devices for Streets and Highways; Revision AGENCY: Federal Highway Administration (FHWA...

  14. 77 FR 28460 - National Standards for Traffic Control Devices; the Manual on Uniform Traffic Control Devices for...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-05-14

    ...-2010-0159] RIN 2125-AF43 National Standards for Traffic Control Devices; the Manual on Uniform Traffic Control Devices for Streets and Highways; Revision AGENCY: Federal Highway Administration (FHWA..., approved by the FHWA, and recognized as the national standard for traffic control devices used on all...

  15. Field Operations and Enforcement Manual for Air Pollution Control. Volume II: Control Technology and General Source Inspection.

    ERIC Educational Resources Information Center

    Weisburd, Melvin I.

    The Field Operations and Enforcement Manual for Air Pollution Control, Volume II, explains in detail the following: technology of source control, modification of operations, particulate control equipment, sulfur dioxide removal systems for power plants, and control equipment for gases and vapors; inspection procedures for general sources, fuel…

  16. An automated workflow for patient-specific quality control of contour propagation

    NASA Astrophysics Data System (ADS)

    Beasley, William J.; McWilliam, Alan; Slevin, Nicholas J.; Mackay, Ranald I.; van Herk, Marcel

    2016-12-01

    Contour propagation is an essential component of adaptive radiotherapy, but current contour propagation algorithms are not yet sufficiently accurate to be used without manual supervision. Manual review of propagated contours is time-consuming, making routine implementation of real-time adaptive radiotherapy unrealistic. Automated methods of monitoring the performance of contour propagation algorithms are therefore required. We have developed an automated workflow for patient-specific quality control of contour propagation and validated it on a cohort of head and neck patients, on which parotids were outlined by two observers. Two types of error were simulated—mislabelling of contours and introducing noise in the scans before propagation. The ability of the workflow to correctly predict the occurrence of errors was tested, taking both sets of observer contours as ground truth, using receiver operator characteristic analysis. The area under the curve was 0.90 and 0.85 for the observers, indicating good ability to predict the occurrence of errors. This tool could potentially be used to identify propagated contours that are likely to be incorrect, acting as a flag for manual review of these contours. This would make contour propagation more efficient, facilitating the routine implementation of adaptive radiotherapy.

  17. A Comparison of a Brain-Based Adaptive System and a Manual Adaptable System for Invoking Automation

    NASA Technical Reports Server (NTRS)

    Bailey, Nathan R.; Scerbo, Mark W.; Freeman, Frederick G.; Mikulka, Peter J.; Scott, Lorissa A.

    2004-01-01

    Two experiments are presented that examine alternative methods for invoking automation. In each experiment, participants were asked to perform simultaneously a monitoring task and a resource management task as well as a tracking task that changed between automatic and manual modes. The monitoring task required participants to detect failures of an automated system to correct aberrant conditions under either high or low system reliability. Performance on each task was assessed as well as situation awareness and subjective workload. In the first experiment, half of the participants worked with a brain-based system that used their EEG signals to switch the tracking task between automatic and manual modes. The remaining participants were yoked to participants from the adaptive condition and received the same schedule of mode switches, but their EEG had no effect on the automation. Within each group, half of the participants were assigned to either the low or high reliability monitoring task. In addition, within each combination of automation invocation and system reliability, participants were separated into high and low complacency potential groups. The results revealed no significant effects of automation invocation on the performance measures; however, the high complacency individuals demonstrated better situation awareness when working with the adaptive automation system. The second experiment was the same as the first with one important exception. Automation was invoked manually. Thus, half of the participants pressed a button to invoke automation for 10 s. The remaining participants were yoked to participants from the adaptable condition and received the same schedule of mode switches, but they had no control over the automation. The results showed that participants who could invoke automation performed more poorly on the resource management task and reported higher levels of subjective workload. Further, those who invoked automation more frequently performed more poorly on the tracking task and reported higher levels of subjective workload. and the adaptable condition in the second experiment revealed only one significant difference: the subjective workload was higher in the adaptable condition. Overall, the results show that a brain-based, adaptive automation system may facilitate situation awareness for those individuals who are more complacent toward automation. By contrast, requiring operators to invoke automation manually may have some detrimental impact on performance but does appear to increases subjective workload relative to an adaptive system.

  18. Parenting Skills: A Trainer's Manual. A Performance Based Early Childhood-Special Education Teacher Preparation Program. Monograph 3.

    ERIC Educational Resources Information Center

    Abidin, Richard R.

    This manual, developed as part of the performance-based Early Childhood-Special Education Teacher Preparation Program, is a trainer's manual for teaching parenting skills. Each module or set of modules presents effective skills for managing and changing behaviors of adults and children. Several profession strategies and theoretical orientations…

  19. Prototype of a computer method for designing and analyzing heating, ventilating and air conditioning proportional, electronic control systems

    NASA Astrophysics Data System (ADS)

    Barlow, Steven J.

    1986-09-01

    The Air Force needs a better method of designing new and retrofit heating, ventilating and air conditioning (HVAC) control systems. Air Force engineers currently use manual design/predict/verify procedures taught at the Air Force Institute of Technology, School of Civil Engineering, HVAC Control Systems course. These existing manual procedures are iterative and time-consuming. The objectives of this research were to: (1) Locate and, if necessary, modify an existing computer-based method for designing and analyzing HVAC control systems that is compatible with the HVAC Control Systems manual procedures, or (2) Develop a new computer-based method of designing and analyzing HVAC control systems that is compatible with the existing manual procedures. Five existing computer packages were investigated in accordance with the first objective: MODSIM (for modular simulation), HVACSIM (for HVAC simulation), TRNSYS (for transient system simulation), BLAST (for building load and system thermodynamics) and Elite Building Energy Analysis Program. None were found to be compatible or adaptable to the existing manual procedures, and consequently, a prototype of a new computer method was developed in accordance with the second research objective.

  20. Does haptic steering guidance instigate speeding? A driving simulator study into causes and remedies.

    PubMed

    Melman, T; de Winter, J C F; Abbink, D A

    2017-01-01

    An important issue in road traffic safety is that drivers show adverse behavioral adaptation (BA) to driver assistance systems. Haptic steering guidance is an upcoming assistance system which facilitates lane-keeping performance while keeping drivers in the loop, and which may be particularly prone to BA. Thus far, experiments on haptic steering guidance have measured driver performance while the vehicle speed was kept constant. The aim of the present driving simulator study was to examine whether haptic steering guidance causes BA in the form of speeding, and to evaluate two types of haptic steering guidance designed not to suffer from BA. Twenty-four participants drove a 1.8m wide car for 13.9km on a curved road, with cones demarcating a single 2.2m narrow lane. Participants completed four conditions in a counterbalanced design: no guidance (Manual), continuous haptic guidance (Cont), continuous guidance that linearly reduced feedback gains from full guidance at 125km/h towards manual control at 130km/h and above (ContRF), and haptic guidance provided only when the predicted lateral position was outside a lateral bandwidth (Band). Participants were familiarized with each condition prior to the experimental runs and were instructed to drive as they normally would while minimizing the number of cone hits. Compared to Manual, the Cont condition yielded a significantly higher driving speed (on average by 7km/h), whereas ContRF and Band did not. All three guidance conditions yielded better lane-keeping performance than Manual, whereas Cont and ContRF yielded lower self-reported workload than Manual. In conclusion, continuous steering guidance entices drivers to increase their speed, thereby diminishing its potential safety benefits. It is possible to prevent BA while retaining safety benefits by making a design adjustment either in lateral (Band) or in longitudinal (ContRF) direction. Copyright © 2016. Published by Elsevier Ltd.

  1. Safe, Effective Use of Pesticides, A Manual for Commercial Applicators: Home, Institutional, and Structural Pest Control.

    ERIC Educational Resources Information Center

    Extension Service (USDA), Washington, DC.

    This manual is designed to assist pest control operators to prepare for certification under the Michigan Pesticide Control Act of 1976. The primary focus of this publication is on home, institutional, and structural pest control. The ten sections included describe: (1) Insect control; (2) Rodent control; (3) Special situation pest control; (4)…

  2. Safe Manual Jettison

    NASA Technical Reports Server (NTRS)

    Barton, Jay

    2008-01-01

    In space, the controlled release of certain cargoes is no less useful than the maritime jettisons from which they take their name but is also much more dangerous. Experience has shown that jettisons can be performed safely, but the process is complicated with the path to performing a jettison taking months or even years. In the background, time is also required to write procedures, train the crew, configure the vehicle, and many other activities. This paper outlines the current process used by the National Aeronautics and Space Administration (NASA) for manual jettisons, detailing the methods used to assure that the jettisons and the jettisoned objects are as safe as achievable and that the crew is adequately trained to be able to affect the safe jettison. The goal of this paper is not only to capture what it takes to perform safe jettisons in the near Earth environment but to extrapolate this knowledge to future space exploration scenarios that will likely have Extravehicular Activity (EVA) and International Partner (IP) interfaces.

  3. Diagnosis from functional perspectives: usefulness of a manual tactile test for predicting precision pinch performance and disease severity in subjects with carpal tunnel syndrome.

    PubMed

    Hsu, Hsiu-Yun; Kuo, Yao-Lung; Jou, I-Ming; Su, Fong-Chin; Chiu, Haw-Yen; Kuo, Li-Chieh

    2014-04-01

    To investigate how the severity levels revealed in a nerve conduction study (NCS) affect the results of the Manual Tactile Test (MTT) for patients with carpal tunnel syndrome (CTS), and to examine the relationships between the results of the MTT and precision pinch performance. Case-control studies. Hospital and local community. Patients with CTS (N=70) with 119 affected hands were studied. A control group matched by age, sex, and hand dominance was also recruited. Not applicable. CTS severity was determined based on NCS findings. The MTT, traditional sensory tests, and precision pinch performance were used to examine the functional sensory status of the hand from different perspectives. The patients with CTS exhibited deterioration in all of the sensibility tests (P<.001). The results showed that the MTT could classify subgroups of severity in CTS (P<.001). A moderate correlation was found between the results of the MTT and precision pinch performance (r=.526-.585, P<.001). Multiple linear regression analysis showed that the MTT results were useful indicators for predicting precision pinch performance and differentiating severity in subjects with CTS (r(2)=.376 and .323, respectively). The findings indicate that the MTT could be a valid and useful assessment for hand sensibility and prehensile pinch performance in patients with CTS. Copyright © 2014 American Congress of Rehabilitation Medicine. Published by Elsevier Inc. All rights reserved.

  4. [Evaluation of postoperative pain comparing manual and ultrasonic endodontic instrumentation in patients with cleft lip and palate].

    PubMed

    Brosco, H B; Pimentel, P A; Lacerda, A G; Nishiyama, C K; de Moraes, I G

    1989-01-01

    Our purpose was to compare incidence of post-surgical pain associated to the endodontic therapy where the instrumentation on the root canal was performed by the method of Marshall & Pappin and the method of Marshall & Pappin complemented by the ultrasonic. Seventy patients with only one tooth needing endodontic treatment were treated by one of the methods and, posteriorly, evaluated. The endodontic treatment was performed at one time and from the seventy teeth, thirty have been instrumented by the manual method complemented by the ultrasonic and forty by the manual instrumentation. The patients were clinically controlled after the endodontic treatment was finished during periods of 24, 48 and 72 hours to evaluate their post-surgical condition. The results suggest that were no statistically significant differences (p less than 0.05) in the incidence of pain between the employed methods or according to the pulpar semiologic condition in any of the observed periods. However, we have realized that there was a tendency for a smaller percentage of a postoperative pain in those cases of necropulpectamy treated by the endosonic ultrasonic synergistic system. In those cases of biopulpectomy this has been not observed.

  5. 76 FR 69869 - Energy Conservation Program: Test Procedures for Residential Clothes Washers

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-11-09

    ... manual water fill control system, user- adjustable adaptive water fill control system, or adaptive water fill control system with alternate manual water fill control system, use the water fill selector... and transcripts, comments, and other supporting documents/ materials. All documents in the docket are...

  6. Comparison of success rates, learning curves, and inter-subject performance variability of robot-assisted and manual ultrasound-guided nerve block needle guidance in simulation.

    PubMed

    Morse, J; Terrasini, N; Wehbe, M; Philippona, C; Zaouter, C; Cyr, S; Hemmerling, T M

    2014-06-01

    This study focuses on a recently developed robotic nerve block system and its impact on learning regional anaesthesia skills. We compared success rates, learning curves, performance times, and inter-subject performance variability of robot-assisted vs manual ultrasound (US)-guided nerve block needle guidance. The hypothesis of this study is that robot assistance will result in faster skill acquisition than manual needle guidance. Five co-authors with different experience with nerve blocks and the robotic system performed both manual and robot-assisted, US-guided nerve blocks on two different nerves of a nerve phantom. Ten trials were performed for each of the four procedures. Time taken to move from a shared starting position till the needle was inserted into the target nerve was defined as the performance time. A successful block was defined as the insertion of the needle into the target nerve. Average performance times were compared using analysis of variance. P<0.05 was considered significant. Data presented as mean (standard deviation). All blocks were successful. There were significant differences in performance times between co-authors to perform the manual blocks, either superficial (P=0.001) or profound (P=0.0001); no statistical difference between co-authors was noted for the robot-assisted blocks. Linear regression indicated that the average decrease in time between consecutive trials for robot-assisted blocks of 1.8 (1.6) s was significantly (P=0.007) greater than the decrease for manual blocks of 0.3 (0.3) s. Robot assistance of nerve blocks allows for faster learning of needle guidance over manual positioning and reduces inter-subject performance variability. © The Author [2014]. Published by Oxford University Press on behalf of the British Journal of Anaesthesia. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

  7. Visual Performance Manual.

    ERIC Educational Resources Information Center

    Chaikin, Rosalind B.; And Others

    Intended for classroom teachers, the manual provides an approach to observation, assessment, record keeping, and remediation of students' visual performance. A list of clues for detecting visual performance difficulties and nine laws applicable to visual performance development tasks are given. Described in two sections are the materials, steps,…

  8. Flight directors for STOl aircraft

    NASA Technical Reports Server (NTRS)

    Rabin, U. H.

    1983-01-01

    Flight director logic for flight path and airspeed control of a powered-lift STOL aircraft in the approach, transition, and landing configurations are developed. The methods for flight director design are investigated. The first method is based on the Optimal Control Model (OCM) of the pilot. The second method, proposed here, uses a fixed dynamic model of the pilot in a state space formulation similar to that of the OCM, and includes a pilot work-load metric. Several design examples are presented with various aircraft, sensor, and control configurations. These examples show the strong impact of throttle effectiveness on the performance and pilot work-load associated with manual control of powered-lift aircraft during approach. Improved performed and reduced pilot work-load can be achieved by using direct-lift-control to increase throttle effectiveness.

  9. Twelfth Annual Conference on Manual Control

    NASA Technical Reports Server (NTRS)

    Wempe, T. E.

    1976-01-01

    Main topics discussed cover multi-task decision making, attention allocation and workload measurement, displays and controls, nonvisual displays, tracking and other psychomotor tasks, automobile driving, handling qualities and pilot ratings, remote manipulation, system identification, control models, and motion and visual cues. Sixty-five papers are included with presentations on results of analytical studies to develop and evaluate human operator models for a range of control task, vehicle dynamics and display situations; results of tests of physiological control systems and applications to medical problems; and on results of simulator and flight tests to determine display, control and dynamics effects on operator performance and workload for aircraft, automobile, and remote control systems.

  10. The Relative Success of a Self-Help and a Group-Based Memory Training Program for Older Adults

    PubMed Central

    Hastings, Erin C.; West, Robin L.

    2011-01-01

    This study evaluates self-help and group-based memory training programs to test for their differential impact on memory beliefs and performance. Self-help participants used a manual that presented strategies for name, story, and list recall and practice exercises. Matched content from that same manual was presented by the trainer in 2-hr weekly group sessions for the group-based trainees. Relative to a wait-list control group, most memory measures showed significant gains for both self-help and group-based training, with no significant training condition differences, and these gains were maintained at follow-up. Belief measures showed that locus of control was significantly higher for the self-help and group-based training than the control group; memory self-efficacy significantly declined for controls, increased for group-trained participants, and remained constant in the self-help group. Self-efficacy change in a self-help group may require more opportunities for interacting with peers and/or an instructor emphasizing one's potential for memory change. PMID:19739914

  11. 46 CFR 161.002-12 - Manual fire alarm systems.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... the control unit and terminating at manual fire alarm boxes. Power failure alarm devices may be... specifically approved. (b) Types. Manual fire alarm systems shall be one of the following types, or a... using manually operated fire alarm boxes. (3) Other types as may be developed. (c) Power supply. The...

  12. 46 CFR 161.002-12 - Manual fire alarm systems.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... the control unit and terminating at manual fire alarm boxes. Power failure alarm devices may be... specifically approved. (b) Types. Manual fire alarm systems shall be one of the following types, or a... using manually operated fire alarm boxes. (3) Other types as may be developed. (c) Power supply. The...

  13. 46 CFR 161.002-12 - Manual fire alarm systems.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... the control unit and terminating at manual fire alarm boxes. Power failure alarm devices may be... specifically approved. (b) Types. Manual fire alarm systems shall be one of the following types, or a... using manually operated fire alarm boxes. (3) Other types as may be developed. (c) Power supply. The...

  14. 49 CFR 236.1039 - Operations and Maintenance Manual.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 49 Transportation 4 2010-10-01 2010-10-01 false Operations and Maintenance Manual. 236.1039... Train Control Systems § 236.1039 Operations and Maintenance Manual. (a) The railroad shall catalog and..., modification, inspection, and testing of the PTC system and have them in one Operations and Maintenance Manual...

  15. Identification of the feedforward component in manual control with predictable target signals.

    PubMed

    Drop, Frank M; Pool, Daan M; Damveld, Herman J; van Paassen, Marinus M; Mulder, Max

    2013-12-01

    In the manual control of a dynamic system, the human controller (HC) often follows a visible and predictable reference path. Compared with a purely feedback control strategy, performance can be improved by making use of this knowledge of the reference. The operator could effectively introduce feedforward control in conjunction with a feedback path to compensate for errors, as hypothesized in literature. However, feedforward behavior has never been identified from experimental data, nor have the hypothesized models been validated. This paper investigates human control behavior in pursuit tracking of a predictable reference signal while being perturbed by a quasi-random multisine disturbance signal. An experiment was done in which the relative strength of the target and disturbance signals were systematically varied. The anticipated changes in control behavior were studied by means of an ARX model analysis and by fitting three parametric HC models: two different feedback models and a combined feedforward and feedback model. The ARX analysis shows that the experiment participants employed control action on both the error and the target signal. The control action on the target was similar to the inverse of the system dynamics. Model fits show that this behavior can be modeled best by the combined feedforward and feedback model.

  16. The performance of pile driving systems : inspection manual.

    DOT National Transportation Integrated Search

    1986-12-01

    A study was undertaken on the performance of pile driving systems and the existiny technology for the measurement of performance parameters was reviewed, This report is an inspection manual for use by pile driving inspectors and engineers to ascertai...

  17. Prototype road weather performance management (RWPM) tool installation instructions & user manual.

    DOT National Transportation Integrated Search

    2016-07-20

    This document is the Installation Instructions and User Manual for the Road Weather Performance Management (RW-PM) Tool developed for the project on Development and Demonstration of a Prototype Road Weather Performance Management Application that Use...

  18. Prototype road weather performance management tool : installation instructions & user manual.

    DOT National Transportation Integrated Search

    2016-07-20

    This document is the Installation Instructions and User Manual for the Road Weather Performance Management (RW-PM) Tool developed for the project on Development and Demonstration of a Prototype Road Weather Performance Management Application that Use...

  19. Distress identification manual for the long-term pavement performance program (Fifth revised edition)

    DOT National Transportation Integrated Search

    2014-05-01

    Accurate, consistent, and repeatable distress evaluation surveys can be performed by using the Distress Identification Manual for the Long-Term Pavement Performance Program. Color photographs and drawings illustrate the distresses found in three basi...

  20. The Identification and Modeling of Visual Cue Usage in Manual Control Task Experiments

    NASA Technical Reports Server (NTRS)

    Sweet, Barbara Townsend; Trejo, Leonard J. (Technical Monitor)

    1999-01-01

    Many fields of endeavor require humans to conduct manual control tasks while viewing a perspective scene. Manual control refers to tasks in which continuous, or nearly continuous, control adjustments are required. Examples include flying an aircraft, driving a car, and riding a bicycle. Perspective scenes can arise through natural viewing of the world, simulation of a scene (as in flight simulators), or through imaging devices (such as the cameras on an unmanned aerospace vehicle). Designers frequently have some degree of control over the content and characteristics of a perspective scene; airport designers can choose runway markings, vehicle designers can influence the size and shape of windows, as well as the location of the pilot, and simulator database designers can choose scene complexity and content. Little theoretical framework exists to help designers determine the answers to questions related to perspective scene content. An empirical approach is most commonly used to determine optimum perspective scene configurations. The goal of the research effort described in this dissertation has been to provide a tool for modeling the characteristics of human operators conducting manual control tasks with perspective-scene viewing. This is done for the purpose of providing an algorithmic, as opposed to empirical, method for analyzing the effects of changing perspective scene content for closed-loop manual control tasks.

  1. Applications of "Integrated Data Viewer'' (IDV) in the classroom

    NASA Astrophysics Data System (ADS)

    Nogueira, R.; Cutrim, E. M.

    2006-06-01

    Conventionally, weather products utilized in synoptic meteorology reduce phenomena occurring in four dimensions to a 2-dimensional form. This constitutes a road-block for non-atmospheric-science majors who need to take meteorology as a non-mathematical and complementary course to their major programs. This research examines the use of Integrated Data Viewer-IDV as a teaching tool, as it allows a 4-dimensional representation of weather products. IDV was tested in the teaching of synoptic meteorology, weather analysis, and weather map interpretation to non-science students in the laboratory sessions of an introductory meteorology class at Western Michigan University. Comparison of student exam scores according to the laboratory teaching techniques, i.e., traditional lab manual and IDV was performed for short- and long-term learning. Results of the statistical analysis show that the Fall 2004 students in the IDV-based lab session retained learning. However, in the Spring 2005 the exam scores did not reflect retention in learning when compared with IDV-based and MANUAL-based lab scores (short term learning, i.e., exam taken one week after the lab exercise). Testing the long-term learning, seven weeks between the two exams in the Spring 2005, show no statistically significant difference between IDV-based group scores and MANUAL-based group scores. However, the IDV group obtained exam score average slightly higher than the MANUAL group. Statistical testing of the principal hypothesis in this study, leads to the conclusion that the IDV-based method did not prove to be a better teaching tool than the traditional paper-based method. Future studies could potentially find significant differences in the effectiveness of both manual and IDV methods if the conditions had been more controlled. That is, students in the control group should not be exposed to the weather analysis using IDV during lecture.

  2. Investigation of the effect of conservative interventions in thumb carpometacarpal osteoarthritis: systematic review and meta-analysis.

    PubMed

    Bertozzi, Lucia; Valdes, Kristin; Vanti, Carla; Negrini, Stefano; Pillastrini, Paolo; Villafañe, Jorge Hugo

    2015-01-01

    The purpose of this study was to conduct a current review of randomized controlled trials regarding the effect of conservative interventions on pain and function in people with thumb carpometacarpal (CMC) osteoarthritis (OA), perform a meta-analysis of the findings and summarize current knowledge. Data were obtained from MEDLINE, CINAHL, Embase, PEDro and CENTRAL databases from their inception to May 2014. Reference lists of relevant literature reviews were also searched. All published randomized trials without restrictions to time of publication or language were considered for inclusion. Study subjects were symptomatic adults with thumb CMC OA. Two reviewers independently selected studies, conducted quality assessment and extracted results. Data were pooled in a meta-analysis, when possible, using a random-effects model. Quality of the body evidence was assessed using GRADE approach. Sixteen RCTs involving 1145 participants met the inclusion criteria. Twelve were of high quality (PEDro score > 6). We found moderate quality evidence that manual therapy and therapeutic exercise combined with manual therapy improve pain in thumb CMC OA at short- and intermediate-term follow-up, and from low to moderate quality evidences that magneto therapy improves pain and function at short-term follow-up. Orthoses (splints) were found to improve function at long-term follow-up and pinch strength at short-term follow-up. Finally, we found from very low to low-quality evidence that other conservative interventions provide no significant improvement in pain and in function at short- and long-term follow-up. Some of the commonly performed conservative interventions performed in therapy have evidence to support their use to improve hand function and decrease hand pain. Additional research is required to determine the efficacy of other therapeutic interventions that are performed with patients with thumb CMC OA. Manual therapy and exercise are an effective means of improving pain and function at short-term follow-up by patients with thumb CMC OA. Magneto therapy, manual therapy, manual therapy and exercise and Orthoses (splints) were found to have clinically significant results. Very few of the included studies showed a clinically significant effect size in favor of treatment.

  3. 14 CFR 23.1587 - Performance information.

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... 14 Aeronautics and Space 1 2012-01-01 2012-01-01 false Performance information. 23.1587 Section 23... Information Airplane Flight Manual and Approved Manual Material § 23.1587 Performance information. Link to an amendment published at 76 FR 75763, December 2, 2011. Unless otherwise prescribed, performance information...

  4. Comparison of pressure-controlled provocation discography using automated versus manual syringe pump manometry in patients with chronic low back pain.

    PubMed

    Derby, Richard; Lee, Sang Hoon; Lee, Jeong-Eun; Lee, Sang-Heon

    2011-01-01

    The study compares the rate of positive discograms using an automated versus a manual pressure-controlled injection devise and compares the pressure and volume values at various pressures and initial evoked pain and 6/10 or greater evoked pain. A retrospective study prospectively collected patient study data used in a prior prospective study and with prospectively collected data which is routinely collected per our institutional standardized audit protocol. Two custom-built disc manometers (automated injection speed control; manual injection speed control) were sequentially employed during provocation discography in 510 discs of 151 consecutive patients. Two hundred thirty-seven discs of 67 patients with chronic low back pain were evaluated using the automated manometer (automated group) and 273 discs of 84 patients were evaluated with a manual manometer (manual group). No significant differences in positive discogram rates were found between the automated and manual groups (32.1% vs 32.6% per disc, respectively, P>0.05). No significant differences in low-pressure positive discogram rates were found (16.0% vs 15.0% per disc, automated group versus manual group, respectively, P>0.05). However, there were significantly increased volumes and lower pressures at initial and "bad" pain provocation. The study results found equivalent positive discogram rates following a series of pressure-controlled discography using either an automated or manual pressure devise. There were, however significant increases in volume at both initial onset of evoked pain and at 6/10 pain when using the automated injection devise that may have caused the observed lower opening pressure and lower pressure values at initial evoked pain. Assuming increased volumes are innocuous, automated injection is inherently more controlled and may better reduce unintended and often unrecorded spurious high dynamic pressure peaks thereby reducing conscious and unconscious operator bias. Wiley Periodicals, Inc.

  5. An evaluation toolkit for Florida's Commuter Assistance Programs (CAP) : a companion to the 1999 CAP evaluation manual

    DOT National Transportation Integrated Search

    2001-01-01

    This manual is a companion piece to the Commuter Assistance Program Evaluation Manual that was developed to assist Florida's Commuter Assistance Programs (CAP) in their efforts to measure and evaluate their performance. This manual is intended to pro...

  6. Sport stacking activities in school children's motor skill development.

    PubMed

    Li, Yuhua; Coleman, Diane; Ransdell, Mary; Coleman, Lyndsie; Irwin, Carol

    2011-10-01

    This study examined the impact of a 12-wk. sport stacking intervention on reaction time (RT), manual dexterity, and hand-eye coordination in elementary school-aged children. 80 Grade 2 students participated in a 15-min. sport stacking practice session every school day for 12 wk., and were tested on psychomotor performance improvement. Tests for choice RT, manual dexterity, and photoelectric rotary pursuit tracking were conducted pre- and post-intervention for both experimental group (n = 36) and the controls (n = 44) who did no sport stacking. Students who had the intervention showed a greater improvement in two-choice RT. No other group difference was found. Such sport stacking activities may facilitate children's central processing and perceptual-motor integration.

  7. Motor and cognitive performance of overweight preschool children.

    PubMed

    Krombholz, Heinz

    2013-02-01

    Gross and fine motor skills and cognitive performance in obese and overweight children were compared to healthy weight children. Participants were 1,543 children (797 boys and 746 girls) ages 43 to 84 months, attending childcare centers in Munich, Germany. According to German Body Mass Index (BMI) standards for age and sex, 4.6% of the children were classified as obese (percentile greater or equal 97), 6.8% as overweight (percentile greater or equal 90 and less than 97), 5.9% as underweight (percentile less than 10), and 83.1% as being of healthy weight. Dependent variables were physical characteristics (height, weight, skinfold thickness), physical fitness (standing broad jump, shuttle run, hanging), body coordination (balancing forward, balancing backward, lateral jump, hopping), manual dexterity (right and left hand), and cognitive performance (intelligence, verbal ability, concentration). Higher proportions of children from lower socioeconomic and immigrant backgrounds were overweight. There was no association between weight and sex. Overweight children showed lower performance on gross motor skills (coordination and fitness), manual dexterity, and intelligence compared to healthy weight children, even after controlling for the effects of social class and immigration status.

  8. Oral Rehydration Therapy and the Control of Diarrheal Diseases. Training for Development. Peace Corps Information Collection & Exchange Training Manual No. T-34.

    ERIC Educational Resources Information Center

    Clark, Mari; And Others

    This manual was developed to train Peace Corps volunteers and other community health workers in oral rehydration therapy (ORT) and the control of diarrheal diseases. Using a competency-based format, the manual contains six training modules (organized in 22 sessions) that focus on interrelated health education and technical content areas. Each…

  9. The Effect of Ship Inherent Controllability on Piloted Performance: The Simulator Experiment

    DTIC Science & Technology

    1990-10-01

    planned analysis that would look for a dependence of the piloted maneuvers on the inherent controllability of the ships, the transit ccnditions and pilot...instructions were planned to sample the maneuvers needed in a narrow channel. Each run was initialized with the ship to the right of the channel...to Navigation Systems Design Manual for Restricted Waterways," (Smith et al., 1985). As of this writing this revision is planned for calendar year 1991

  10. 40 CFR Appendix Ix to Part 266 - Methods Manual for Compliance With the BIF Regulations

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... Systems 2.1Performance Specifications for Continuous Emission Monitoring of Carbon Monoxide and Oxygen for... Methodology for Bevill Residue Determinations 8.0Procedures for Determining Default Values for Air Pollution Control System Removal Efficiencies 8.1APCS RE Default Values for Metals 8.2APCS RE Default Values for HC1...

  11. 40 CFR Appendix Ix to Part 266 - Methods Manual for Compliance With the BIF Regulations

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... Systems 2.1Performance Specifications for Continuous Emission Monitoring of Carbon Monoxide and Oxygen for... Methodology for Bevill Residue Determinations 8.0Procedures for Determining Default Values for Air Pollution Control System Removal Efficiencies 8.1APCS RE Default Values for Metals 8.2APCS RE Default Values for HC1...

  12. Filter Leaf. Operational Control Tests for Wastewater Treatment Facilities. Instructor's Manual [and] Student Workbook.

    ERIC Educational Resources Information Center

    Wooley, John F.

    In the operation of vacuum filters and belt filters, it is desirable to evaluate the performance of different types of filter media and conditioning processes. The filter leaf test, which is used to evaluate these items, is described. Designed for individuals who have completed National Pollutant Discharge Elimination System (NPDES) level 1…

  13. LANDSAT-D flight segment operations manual, volume 2

    NASA Technical Reports Server (NTRS)

    Varhola, J.

    1981-01-01

    Functions, performance capabilities, modes of operation, constraints, redundancy, commands, and telemetry are described for the thematic mapper; the global positioning system; the direct access S-band; the multispectral scanner; the payload correction; the thermal control subsystem; the solar array retention, deployment, and jettison assembly; and the boom antenna retention, deployment, and jettison assembly for LANDSAT 4.

  14. Development of an automated analysis system for data from flow cytometric intracellular cytokine staining assays from clinical vaccine trials

    PubMed Central

    Shulman, Nick; Bellew, Matthew; Snelling, George; Carter, Donald; Huang, Yunda; Li, Hongli; Self, Steven G.; McElrath, M. Juliana; De Rosa, Stephen C.

    2008-01-01

    Background Intracellular cytokine staining (ICS) by multiparameter flow cytometry is one of the primary methods for determining T cell immunogenicity in HIV-1 clinical vaccine trials. Data analysis requires considerable expertise and time. The amount of data is quickly increasing as more and larger trials are performed, and thus there is a critical need for high throughput methods of data analysis. Methods A web based flow cytometric analysis system, LabKey Flow, was developed for analyses of data from standardized ICS assays. A gating template was created manually in commercially-available flow cytometric analysis software. Using this template, the system automatically compensated and analyzed all data sets. Quality control queries were designed to identify potentially incorrect sample collections. Results Comparison of the semi-automated analysis performed by LabKey Flow and the manual analysis performed using FlowJo software demonstrated excellent concordance (concordance correlation coefficient >0.990). Manual inspection of the analyses performed by LabKey Flow for 8-color ICS data files from several clinical vaccine trials indicates that template gates can appropriately be used for most data sets. Conclusions The semi-automated LabKey Flow analysis system can analyze accurately large ICS data files. Routine use of the system does not require specialized expertise. This high-throughput analysis will provide great utility for rapid evaluation of complex multiparameter flow cytometric measurements collected from large clinical trials. PMID:18615598

  15. Fully Automated Driving: Impact of Trust and Practice on Manual Control Recovery.

    PubMed

    Payre, William; Cestac, Julien; Delhomme, Patricia

    2016-03-01

    An experiment was performed in a driving simulator to investigate the impacts of practice, trust, and interaction on manual control recovery (MCR) when employing fully automated driving (FAD). To increase the use of partially or highly automated driving efficiency and to improve safety, some studies have addressed trust in driving automation and training, but few studies have focused on FAD. FAD is an autonomous system that has full control of a vehicle without any need for intervention by the driver. A total of 69 drivers with a valid license practiced with FAD. They were distributed evenly across two conditions: simple practice and elaborate practice. When examining emergency MCR, a correlation was found between trust and reaction time in the simple practice group (i.e., higher trust meant a longer reaction time), but not in the elaborate practice group. This result indicated that to mitigate the negative impact of overtrust on reaction time, more appropriate practice may be needed. Drivers should be trained in how the automated device works so as to improve MCR performance in case of an emergency. The practice format used in this study could be used for the first interaction with an FAD car when acquiring such a vehicle. © 2015, Human Factors and Ergonomics Society.

  16. 14 CFR 23.1587 - Performance information.

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... 14 Aeronautics and Space 1 2014-01-01 2014-01-01 false Performance information. 23.1587 Section 23.1587 Aeronautics and Space FEDERAL AVIATION ADMINISTRATION, DEPARTMENT OF TRANSPORTATION AIRCRAFT... Information Airplane Flight Manual and Approved Manual Material § 23.1587 Performance information. Unless...

  17. Manual-control Analysis Applied to the Money-supply Control Task

    NASA Technical Reports Server (NTRS)

    Wingrove, R. C.

    1984-01-01

    The recent procedure implemented by the Federal Reserve Board to control the money supply is formulated in the form of a tracking model as used in the study of manual-control tasks. Using this model, an analysis is made to determine the effect of monetary control on the fluctuations in economic output. The results indicate that monetary control can reduce the amplitude of fluctuations at frequencies near the region of historic business cycles. However, with significant time lags in the control loop, monetary control tends to increase the amplitude of the fluctuations at the higher frequencies. How the investigator or student can use the tools developed in the field of manual-control analysis to study the nature of economic fluctuations and to examine different strategies for stabilization is examined.

  18. Turtle Manual.

    ERIC Educational Resources Information Center

    Schneider, Marlene; Robin, Arthur

    This manual describes the Turtle Technique which was developed to help children with behavior problems control their own disruptive behavior. The technique differs from other behavior modification techniques in that it is based upon self-control rather than external control of disruptive behavior. The Turtle Technique first teaches the child how…

  19. Aquatic Pest Control. Manual 99.

    ERIC Educational Resources Information Center

    Missouri Univ., Columbia. Agricultural Experiment Station.

    This training manual provides information needed to meet the minimum EPA standards for certification as a commercial applicator of pesticides in the aquatic pest control category. The text discusses various water use situations; aquatic weed identification; herbicide use and effects; and aquatic insects and their control. (CS)

  20. What is industrial hygiene? | News

    Science.gov Websites

    Radiological Control Manual (FRCM) Graphic design standards Quality Assurance Manual (QAM) Forms Forms , 2016 | Rob Bushek icon icon icon Industrial hygiene is concerned primarily with the control of that science and art devoted to the anticipation, recognition, evaluation and control of those

  1. Job Language Performance Requirements for MOS 75C. Personnel Management Specialist. Reference Soldier’s Manual Dated 22 May 1979.

    DTIC Science & Technology

    1979-05-22

    STANDARDS-1963-A •4 OCT 1982 kJOB LANGUAGE PERFORMANCE REQUIREMENTS FOR 75C PERSONNEL MANAGEENT SPECIALIST REFERENCE SOLDIER’S MANUAL DATED 22 May 1979...task by task listing of the vocabulary extracted from the Soldier’s Manual .. iii [’ Appendix seven contains the machine-generated vocabulary f3r this...Observation Form and an analysis of language structures in the Soldier’s Manual for this MOS. The Observation Form (Appendix 4) was used to record actual

  2. The diagnostic performance of leak-plugging automated segmentation versus manual tracing of breast lesions on ultrasound images.

    PubMed

    Xiong, Hui; Sultan, Laith R; Cary, Theodore W; Schultz, Susan M; Bouzghar, Ghizlane; Sehgal, Chandra M

    2017-05-01

    To assess the diagnostic performance of a leak-plugging segmentation method that we have developed for delineating breast masses on ultrasound images. Fifty-two biopsy-proven breast lesion images were analyzed by three observers using the leak-plugging and manual segmentation methods. From each segmentation method, grayscale and morphological features were extracted and classified as malignant or benign by logistic regression analysis. The performance of leak-plugging and manual segmentations was compared by: size of the lesion, overlap area ( O a ) between the margins, and area under the ROC curves ( A z ). The lesion size from leak-plugging segmentation correlated closely with that from manual tracing ( R 2 of 0.91). O a was higher for leak plugging, 0.92 ± 0.01 and 0.86 ± 0.06 for benign and malignant masses, respectively, compared to 0.80 ± 0.04 and 0.73 ± 0.02 for manual tracings. Overall O a between leak-plugging and manual segmentations was 0.79 ± 0.14 for benign and 0.73 ± 0.14 for malignant lesions. A z for leak plugging was consistently higher (0.910 ± 0.003) compared to 0.888 ± 0.012 for manual tracings. The coefficient of variation of A z between three observers was 0.29% for leak plugging compared to 1.3% for manual tracings. The diagnostic performance, size measurements, and observer variability for automated leak-plugging segmentations were either comparable to or better than those of manual tracings.

  3. Verification test results of Apollo stabilization and control systems during undocked operations

    NASA Technical Reports Server (NTRS)

    Copeland, E. L.; Haken, R. L.

    1974-01-01

    The results are presented of analysis and simulation testing of both the Skylark 1 reaction control system digital autopilot (RCS DAP) and the thrust vector control (TVC) autopilot for use during the undocked portions of the Apollo/Soyuz Test Project Mission. The RCS DAP testing was performed using the Skylab Functional Simulator (SLFS), a digital computer program capable of simulating the Apollo and Skylab autopilots along with vehicle dynamics including bending and sloshing. The model is used to simulate three-axis automatic maneuvers along with pilot controlled manual maneuvers using the RCS DAP. The TVC autopilot was tested in two parts. A classical stability analysis was performed on the vehicle considering the effects of structural bending and sloshing when under control of the TVC autopilot. The time response of the TVC autopilot was tested using the SLFS. Results indicate that adequate performance stability margins can be expected for the CSM/DM configuration when under the control of the Apollo control systems tested.

  4. Tool Support for Software Lookup Table Optimization

    DOE PAGES

    Wilcox, Chris; Strout, Michelle Mills; Bieman, James M.

    2011-01-01

    A number of scientific applications are performance-limited by expressions that repeatedly call costly elementary functions. Lookup table (LUT) optimization accelerates the evaluation of such functions by reusing previously computed results. LUT methods can speed up applications that tolerate an approximation of function results, thereby achieving a high level of fuzzy reuse. One problem with LUT optimization is the difficulty of controlling the tradeoff between performance and accuracy. The current practice of manual LUT optimization adds programming effort by requiring extensive experimentation to make this tradeoff, and such hand tuning can obfuscate algorithms. In this paper we describe a methodology andmore » tool implementation to improve the application of software LUT optimization. Our Mesa tool implements source-to-source transformations for C or C++ code to automate the tedious and error-prone aspects of LUT generation such as domain profiling, error analysis, and code generation. We evaluate Mesa with five scientific applications. Our results show a performance improvement of 3.0× and 6.9× for two molecular biology algorithms, 1.4× for a molecular dynamics program, 2.1× to 2.8× for a neural network application, and 4.6× for a hydrology calculation. We find that Mesa enables LUT optimization with more control over accuracy and less effort than manual approaches.« less

  5. Delayed visual feedback affects both manual tracking and grip force control when transporting a handheld object.

    PubMed

    Sarlegna, Fabrice R; Baud-Bovy, Gabriel; Danion, Frédéric

    2010-08-01

    When we manipulate an object, grip force is adjusted in anticipation of the mechanical consequences of hand motion (i.e., load force) to prevent the object from slipping. This predictive behavior is assumed to rely on an internal representation of the object dynamic properties, which would be elaborated via visual information before the object is grasped and via somatosensory feedback once the object is grasped. Here we examined this view by investigating the effect of delayed visual feedback during dextrous object manipulation. Adult participants manually tracked a sinusoidal target by oscillating a handheld object whose current position was displayed as a cursor on a screen along with the visual target. A delay was introduced between actual object displacement and cursor motion. This delay was linearly increased (from 0 to 300 ms) and decreased within 2-min trials. As previously reported, delayed visual feedback altered performance in manual tracking. Importantly, although the physical properties of the object remained unchanged, delayed visual feedback altered the timing of grip force relative to load force by about 50 ms. Additional experiments showed that this effect was not due to task complexity nor to manual tracking. A model inspired by the behavior of mass-spring systems suggests that delayed visual feedback may have biased the representation of object dynamics. Overall, our findings support the idea that visual feedback of object motion can influence the predictive control of grip force even when the object is grasped.

  6. Teacher Performance Assessment Instruments: A Guide to Interpretation.

    ERIC Educational Resources Information Center

    Capie, William; And Others

    This manual was prepared to assist in the development of skills requisite to rating the performance of student or beginning teachers. The activities prescribed in the manual are intended to enable experienced teachers to describe the spectrum of performances indicative of the 18 competencies subsumed in the Teacher Performance Assessment…

  7. Basic Emergency Medical Technician Skills Manual.

    ERIC Educational Resources Information Center

    Oklahoma State Dept. of Vocational and Technical Education, Stillwater. Curriculum and Instructional Materials Center.

    This manual was developed to help students preparing to become emergency medical technicians (EMTs) learn standardized basic skills in the field. The manual itemizes the steps and performance criteria of each required skill and uses an accompanying videotape series (not included) to enhance the educational experience. The five units of the manual,…

  8. Enhanced Engine Control for Emergency Operation

    NASA Technical Reports Server (NTRS)

    Litt, Jonathan S.

    2012-01-01

    C-MAPSS40k engine simulation has been developed and is available to the public. The authenticity of the engine performance and controller enabled the development of realistic enhanced control modes through controller modification alone. Use of enhanced control modes improved stability and control of an impaired aircraft. - Fast Response is useful for manual manipulation of the throttles - Use of Fast Response improved stability as part of a yaw rate feedback system. - Use of Overthrust shortened takeoff distance, but was generally useful in flight, too. Initial lack of pilot familiarity resulted in discomfort, especially with yaw rate feedback, but that was the only drawback, overall the pilot found the enhanced modes very helpful.

  9. [Regulation of hypnosis in Propofol anesthesia administration based on non-linear control strategy].

    PubMed

    Ilyas, Muhammad; Khaqan, Ali; Iqbal, Jamshed; Riaz, Raja Ali

    Continuous adjustment of Propofol in manual delivery of anesthesia for conducting a surgical procedure overburdens the workload of an anesthetist who is working in a multi-tasking scenario. Going beyond manual administration and Target Controlled Infusion, closed-loop control of Propofol infusion has the potential to offer several benefits in terms of handling perturbations and reducing the effect of inter-patient variability. This paper proposes a closed-loop automated drug administration approach to control Depth Of Hypnosis in anesthesia. In contrast with most of the existing research on anesthesia control which makes use of linear control strategies or their improved variants, the novelty of the present research lies in applying robust control strategy i.e. Sliding Mode Control to accurately control drug infusion. Based on the derived patient's model, the designed controller uses measurements from EEG to regulate DOH on Bispectral Index by controlling infusion rate of Propofol. The performance of the controller is investigated and characterized with real dataset of 8 patients undergoing surgery. Results of this in silico study indicate that for all the patients, with 0% overshoot observed, the steady state error lies in between ±5. Clinically, this implies that in all the cases, without any overdose, the controller maintains the desired DOH level for smooth conduction of surgical procedures. Copyright © 2016 Sociedade Brasileira de Anestesiologia. Publicado por Elsevier Editora Ltda. All rights reserved.

  10. Regulation of hypnosis in Propofol anesthesia administration based on non-linear control strategy.

    PubMed

    Ilyas, Muhammad; Khaqan, Ali; Iqbal, Jamshed; Riaz, Raja Ali

    Continuous adjustment of Propofol in manual delivery of anesthesia for conducting a surgical procedure overburdens the workload of an anesthetist who is working in a multi-tasking scenario. Going beyond manual administration and Target Controlled Infusion, closed-loop control of Propofol infusion has the potential to offer several benefits in terms of handling perturbations and reducing the effect of inter-patient variability. This paper proposes a closed-loop automated drug administration approach to control Depth Of Hypnosis in anesthesia. In contrast with most of the existing research on anesthesia control which makes use of linear control strategies or their improved variants, the novelty of the present research lies in applying robust control strategy i.e. Sliding Mode Control to accurately control drug infusion. Based on the derived patient's model, the designed controller uses measurements from EEG to regulate DOH on Bispectral Index by controlling infusion rate of Propofol. The performance of the controller is investigated and characterized with real dataset of 8 patients undergoing surgery. Results of this in silico study indicate that for all the patients, with 0% overshoot observed, the steady state error lies in between ±5. Clinically, this implies that in all the cases, without any overdose, the controller maintains the desired DOH level for smooth conduction of surgical procedures. Copyright © 2016 Sociedade Brasileira de Anestesiologia. Published by Elsevier Editora Ltda. All rights reserved.

  11. The effectiveness of manual physical therapy interventions in pediatric patients with anterior hip pain: a retrospective study.

    PubMed

    Galleher, Mindy; Crowe, Briana; Selhorst, Mitchell

    2017-12-01

    The purposes of this study were to: (1) assess the benefit of adding manual therapy (MT) to physical therapy care in pediatric patients with anterior hip pain; (2) assess the relative risk of adverse reactions when MT is used; and (3) report the types of MT used. This study was a retrospective chart review of patients treated in a hospital-based sports medicine clinic. The charts of 201 patients (mean age = 14.23 ± 2.15 years) met the inclusion criteria and were reviewed. Patients were grouped into those who received MT during their episode of care, and those who did not. Pain efficiency (change in pain/number of visits), number and type of adverse reactions, as well as frequency and type of manual therapy interventions used, were the outcomes of interest. The mean pain efficiency was significantly less if manual therapy was performed (MT = 0.60 [95% CI 0.47-0.72], no MT = 0.80 [95% CI 0.71-0.90] p  = 0.01). There was no significant difference between groups in risk of adverse reactions (MT = 5, no MT = 5). The number of visits was significantly different between groups (MT = 9.43 ± 3.9 sessions, and no MT = 7.6 ± 5.2 sessions). MT did not increase the risk of an adverse reaction in pediatric patients with anterior hip pain. While it appears to be a safe intervention, it did not improve pain efficiency or patient adherence. Future research should be performed to assess the effectiveness of MT, when performed by skilled therapists, in pediatric patients with hip pain in a controlled manner. Level of Evidence: 3b.

  12. Process Control Manual for Aerobic Biological Wastewater Treatment Facilities.

    ERIC Educational Resources Information Center

    Environmental Protection Agency, Washington, DC. Office of Water Programs.

    This Environmental Protection Agency (EPA) publication is an operations manual for activated sludge and trickling filter wastewater treatment facilities. The stated purpose of the manual is to provide an on-the-job reference for operators of these two types of treatment plants. The overall objective of the manual is to aid the operator in…

  13. The Effect of Part-simulation of Weightlessness on Human Control of Bilateral Teleoperation: Neuromotor Considerations

    NASA Technical Reports Server (NTRS)

    Corker, K.; Bejczy, A. K.

    1984-01-01

    The effect of weightlessness on the human operator's performance in force reflecting position control of remote manipulators was investigated. A gravity compensation system was developed to simulate the effect of weightlessness on the operator's arm. A universal force reflecting hand controller (FRHC) and task simulation software were employed. Two experiments were performed because of anticipated disturbances in neuromotor control specification on the human operator in an orbital control environment to investigate: (1) the effect of controller stiffness on the attainment of a learned terminal position in the three dimensional controller space, and (2) the effect of controller stiffness and damping on force tracking of the contour of a simulated three dimensional cube using the part simulation of weightless conditions. The results support the extension of neuromotor control models, which postulate a stiffness balance encoding of terminal position, to three dimensional motion of a multilink system, confirm the existence of a disturbance in human manual control performance under gravity compensated conditions, and suggest techniques for compensation of weightlessness induced performance decrement through appropriate specification of hand controller response characteristics. These techniques are based on the human control model.

  14. Neuromapping: Inflight Evaluation of Cognition and Adaptability

    NASA Technical Reports Server (NTRS)

    Kofman, I. S.; De Dios, Y. E.; Lawrence, K.; Schade, A.; Reschke, M. F.; Bloomberg, J. J.; Wood, S. J.; Mulavara, A. P.; Seidle, R. D.

    2016-01-01

    In consideration of the health and performance of crewmembers during flight and postflight, we are conducting a controlled prospective longitudinal study to investigate the effects of spaceflight on the extent, longevity and neural bases of sensorimotor, cognitive, and neural changes. Previous studies investigating sensorimotor adaptation to the microgravity environment longitudinally inflight have shown reduction in the ability to perform complex dual tasks. In this study we perform a series of tests investigating the longitudinal effects of adaptation to the microgravity environment and how it affects spatial cognition, manual visuo-motor adaption and dual tasking.

  15. A spectral power analysis of driving behavior changes during the transition from nondistraction to distraction.

    PubMed

    Wang, Yuan; Bao, Shan; Du, Wenjun; Ye, Zhirui; Sayer, James R

    2017-11-17

    This article investigated and compared frequency domain and time domain characteristics of drivers' behaviors before and after the start of distracted driving. Data from an existing naturalistic driving study were used. Fast Fourier transform (FFT) was applied for the frequency domain analysis to explore drivers' behavior pattern changes between nondistracted (prestarting of visual-manual task) and distracted (poststarting of visual-manual task) driving periods. Average relative spectral power in a low frequency range (0-0.5 Hz) and the standard deviation in a 10-s time window of vehicle control variables (i.e., lane offset, yaw rate, and acceleration) were calculated and further compared. Sensitivity analyses were also applied to examine the reliability of the time and frequency domain analyses. Results of the mixed model analyses from the time and frequency domain analyses all showed significant degradation in lateral control performance after engaging in visual-manual tasks while driving. Results of the sensitivity analyses suggested that the frequency domain analysis was less sensitive to the frequency bandwidth, whereas the time domain analysis was more sensitive to the time intervals selected for variation calculations. Different time interval selections can result in significantly different standard deviation values, whereas average spectral power analysis on yaw rate in both low and high frequency bandwidths showed consistent results, that higher variation values were observed during distracted driving when compared to nondistracted driving. This study suggests that driver state detection needs to consider the behavior changes during the prestarting periods, instead of only focusing on periods with physical presence of distraction, such as cell phone use. Lateral control measures can be a better indicator of distraction detection than longitudinal controls. In addition, frequency domain analyses proved to be a more robust and consistent method in assessing driving performance compared to time domain analyses.

  16. Entry dynamics of space shuttle orbiter with lateral-directional stability and control uncertainties at supersonic and hypersonic speeds

    NASA Technical Reports Server (NTRS)

    Stone, H. W.; Powell, R. W.

    1977-01-01

    A six-degree-of-freedom simulation analysis was conducted to examine the effects of the lateral-directional static aerodynamic stability and control uncertainties on the performance of the automatic (no manual inputs) entry-guidance and control systems of the space shuttle orbiter. To establish the acceptable boundaries of the uncertainties, the static aerodynamic characteristics were varied either by applying a multiplier to the aerodynamic parameter or by adding an increment. Control-system modifications were identified that decrease the sensitivity to off-nominal aerodynamics. With these modifications, the acceptable aerodynamic boundaries were determined.

  17. Creating a systems engineering approach for the manual on uniform traffic control devices.

    DOT National Transportation Integrated Search

    2011-03-01

    The Manual on Uniform Traffic Control Devices (MUTCD) provides basic principles for use of traffic : control devices (TCD). However, most TCDs are not explicitly required, and the decision to use a given : TCD in a given situation is typically made b...

  18. Ornamental and Turf Pest Control for Commercial Applicators: Pest Control of Ornamental Plants; NCR 12, Lawn Diseases in the Midwest; NCR 26, Lawn Weeds and their Control. Manual 89.

    ERIC Educational Resources Information Center

    Craig, W. S., Comp.; And Others

    This training manual provides information needed to meet the minimum EPA standards for certification as a commercial applicator of pesticides in the ornamental and turf pest control category. The text discusses pest control of ornamental plants, lawn diseases, and lawn weeds and their control. (CS)

  19. Intravenous nitroglycerin for controlled cord traction in the management of retained placenta.

    PubMed

    Visalyaputra, Shusee; Prechapanich, Japarath; Suwanvichai, Sukanya; Yimyam, Suwimol; Permpolprasert, Ladda; Suksopee, Pattipa

    2011-02-01

    To determine the effect of 200 μg of intravenous nitroglycerin in the release of retained placenta by controlled cord traction. In this randomized controlled study, 40 women with a placenta retained for 30 minutes received intravenously 200 μg of nitroglycerin or a normal saline solution before umbilical cord traction was initiated. The rates of successful removal of the retained placenta in the study (n=20) and control (n=20) groups were compared, as were blood pressure, pulse rate, blood loss, and adverse effects. The placenta was released in only 15% and 20% of the participants in the study and control group, respectively. The remainder of the participants required general anesthesia and manual removal of the retained placenta regardless of group assignation. Blood pressure fell in significantly more women in the study group, but there were no differences in estimated blood loss or minor adverse effects. Intravenously administered nitroglycerin did not facilitate the release of retained placenta by umbilical cord traction. However, cord traction may be performed longer than 30 minutes to attempt releasing the placenta before operative manual removal is initiated. Copyright © 2010 International Federation of Gynecology and Obstetrics. Published by Elsevier Ireland Ltd. All rights reserved.

  20. Magnetic versus manual catheter navigation for mapping and ablation of right ventricular outflow tract ventricular arrhythmias: a randomized controlled study.

    PubMed

    Zhang, Fengxiang; Yang, Bing; Chen, Hongwu; Ju, Weizhu; Kojodjojo, Pipin; Cao, Kejiang; Chen, Minglong

    2013-08-01

    No randomized controlled study has prospectively compared the performance and clinical outcomes of remote magnetic control (RMC) vs manual catheter control (MCC) during ablation of right ventricular outflow tract (RVOT) ventricular premature complexes (VPC) or ventricular tachycardia (VT). The purpose of this study was to prospectively evaluate the efficacy and safety of using either RMC vs MCC for mapping and ablation of RVOT VPC/VT. Thirty consecutive patients with idiopathic RVOT VPC/VT were referred for catheter ablation and randomized into either the RMC or MCC group. A noncontact mapping system was deployed in the RVOT to identify origins of VPC/VT. Conventional activation and pace-mapping was performed to guide ablation. If ablation performed using 1 mode of catheter control was acutely unsuccessful, the patient crossed over to the other group. The primary endpoints were patients' and physicians' fluoroscopic exposure and times. Mean procedural times were similar between RMC and MCC groups. The fluoroscopic exposure and times for both patients and physicians were much lower in the RMC group than in the MCC group. Ablation was acutely successful in 14 of 15 patients in the MCC group and 10 of 15 in the RMC group. Following crossover, acute success was achieved in all patients. No major complications occurred in either group. During 22 months of follow-up, RVOT VPC recurred in 2 RMC patients. RMC navigation significantly reduces patients' and physicians' fluoroscopic times by 50.5% and 68.6%, respectively, when used in conjunction with a noncontact mapping system to guide ablation of RVOT VPC/VT. Copyright © 2013 Heart Rhythm Society. Published by Elsevier Inc. All rights reserved.

  1. Advanced figure sensor operations and maintenance manual

    NASA Technical Reports Server (NTRS)

    Robertson, H. J.

    1972-01-01

    This manual contains procedures for installing, operating, and maintaining the optical figure sensor and its associated electronic controls. The optical figure sensor, a system of integrated components, comprises: (1) a phase measuring modified interferometer employing a single frequency 6328 A laser, and a Vidissector; (2) a two-axis automatic thermal compensation control mount; (3) a five degree of freedom manual adjustment stand; and (4) a control console. This instrument provides real time output data of optical figure errors for spherical mirrors, and is also capable of measuring aspherical mirrors if a null corrector is added.

  2. Control technology appendices for pollution control technical manuals. Final report, June 1982-February 1983

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Not Available

    1983-04-01

    The document is one of six technical handbooks prepared by EPA to help government officials granting permits to build synfuels facilities, synfuels process developers, and other interested parties. They provide technical data on waste streams from synfuels facilities and technologies capable of controlling them. Process technologies covered in the manuals include coal gasification, coal liquefaction by direct and idirect processing, and the extraction of oil from shale. The manuals offer no regulatory guidance, allowing the industry flexibility in deciding how best to comply with environmental regulations.

  3. Using real-time ultrasound imaging as adjunct teaching tools to enhance physical therapist students' ability and confidence to perform traction of the knee joint.

    PubMed

    Markowski, Alycia; Watkins, Maureen K; Burnett, Todd; Ho, Melissa; Ling, Michael

    2018-04-01

    Often, physical therapy students struggle with the skill and the confidence to perform manual techniques for musculoskeletal examination. Current teaching methods lack concurrent objective feedback. Real-time ultrasound imaging (RTUI) has the advantage of generating visualization of anatomical structures in real-time in an efficient and safe manner. We hypothesize that the use of RTUI to augment teaching with concurrent objective visual feedback will result in students' improved ability to create a change in joint space when performing a manual knee traction and higher confidence scores. Eighty-six students were randomly allocated to a control or an experimental group. All participants received baseline instructions on how to perform knee traction. The control group received standardized lab instruction (visual, video, and instructor/partner feedback). The experimental group received standardized lab instruction augmented with RTUI feedback. Pre-data and post-data collection consisted of measuring participants' ability to create changes in joint space when performing knee traction, a confidence survey evaluating perceived ability and a reflection paper. Joint space changes between groups were compared using a paired t-test. Surveys were analyzed with descriptive statistics and compared using Wilcoxon Rank Sum and for the reflection papers, themes were identified and descriptive statistics reported. Although there were no statistically significant differences between the control and the experimental group, overall scores improved. Qualitative data suggests students found the use of ultrasound imaging beneficial and would like more exposure. This novel approach to teaching knee traction with RTUI has potential and may be a basis for further studies. Copyright © 2018 Elsevier Ltd. All rights reserved.

  4. Idiosyncratic representation of peripersonal space depends on the success of one's own motor actions, but also the successful actions of others!

    PubMed Central

    Quesque, François; Gigliotti, Maria-Francesca; Ott, Laurent; Bruyelle, Jean-Luc

    2018-01-01

    Peripersonal space is a multisensory representation of the environment around the body in relation to the motor system, underlying the interactions with the physical and social world. Although changing body properties and social context have been shown to alter the functional processing of space, little is known about how changing the value of objects influences the representation of peripersonal space. In two experiments, we tested the effect of modifying the spatial distribution of reward-yielding targets on manual reaching actions and peripersonal space representation. Before and after performing a target-selection task consisting of manually selecting a set of targets on a touch-screen table, participants performed a two-alternative forced-choice reachability-judgment task. In the target-selection task, half of the targets were associated with a reward (change of colour from grey to green, providing 1 point), the other half being associated with no reward (change of colour from grey to red, providing no point). In Experiment 1, the target-selection task was performed individually with the aim of maximizing the point count, and the distribution of the reward-yielding targets was either 50%, 25% or 75% in the proximal and distal spaces. In Experiment 2, the target-selection task was performed in a social context involving cooperation between two participants to maximize the point count, and the distribution of the reward-yielding targets was 50% in the proximal and distal spaces. Results showed that changing the distribution of the reward-yielding targets or introducing the social context modified concurrently the amplitude of self-generated manual reaching actions and the representation of peripersonal space. Moreover, a decrease of the amplitude of manual reaching actions caused a reduction of peripersonal space when resulting from the distribution of reward-yielding targets, while this effect was not observed in a social interaction context. In that case, the decreased amplitude of manual reaching actions was accompanied by an increase of peripersonal space representation, which was not due to the mere presence of a confederate (control experiment). We conclude that reward-dependent modulation of objects values in the environment modifies the representation of peripersonal space, when resulting from either self-generated motor actions or observation of motor actions performed by a confederate. PMID:29771982

  5. Idiosyncratic representation of peripersonal space depends on the success of one's own motor actions, but also the successful actions of others!

    PubMed

    Coello, Yann; Quesque, François; Gigliotti, Maria-Francesca; Ott, Laurent; Bruyelle, Jean-Luc

    2018-01-01

    Peripersonal space is a multisensory representation of the environment around the body in relation to the motor system, underlying the interactions with the physical and social world. Although changing body properties and social context have been shown to alter the functional processing of space, little is known about how changing the value of objects influences the representation of peripersonal space. In two experiments, we tested the effect of modifying the spatial distribution of reward-yielding targets on manual reaching actions and peripersonal space representation. Before and after performing a target-selection task consisting of manually selecting a set of targets on a touch-screen table, participants performed a two-alternative forced-choice reachability-judgment task. In the target-selection task, half of the targets were associated with a reward (change of colour from grey to green, providing 1 point), the other half being associated with no reward (change of colour from grey to red, providing no point). In Experiment 1, the target-selection task was performed individually with the aim of maximizing the point count, and the distribution of the reward-yielding targets was either 50%, 25% or 75% in the proximal and distal spaces. In Experiment 2, the target-selection task was performed in a social context involving cooperation between two participants to maximize the point count, and the distribution of the reward-yielding targets was 50% in the proximal and distal spaces. Results showed that changing the distribution of the reward-yielding targets or introducing the social context modified concurrently the amplitude of self-generated manual reaching actions and the representation of peripersonal space. Moreover, a decrease of the amplitude of manual reaching actions caused a reduction of peripersonal space when resulting from the distribution of reward-yielding targets, while this effect was not observed in a social interaction context. In that case, the decreased amplitude of manual reaching actions was accompanied by an increase of peripersonal space representation, which was not due to the mere presence of a confederate (control experiment). We conclude that reward-dependent modulation of objects values in the environment modifies the representation of peripersonal space, when resulting from either self-generated motor actions or observation of motor actions performed by a confederate.

  6. California Publicly-Owned Utilities (POUs) – LBNL ‘Beyond Widgets’ Project. Task: ambient lighting and occupancy-based plug load control. System Program Manual

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Robinson, Alastair; Mathew, Paul A.; Regnier, Cynthia

    This program manual contains detailed technical information for implementing an incentive program for task-ambient lighting and occupancy-based plug load control. This manual was developed by Lawrence Berkeley National Laboratory, in collaboration with the California Publicly-Owned Utilities (CA POUs) as a partner in the ‘Beyond Widgets’ program funded by the U.S. Department of Energy Building Technologies Office. The primary audience for this manual is the program staff of the various CA POUs. It may also be used by other utility incentive programs to help develop similar programs. It is anticipated that the content of this manual be utilized by the CAmore » POU staff for developing related documents such as the Technical Resource Manual and other filings pertaining to the rollout of an energy systems-based rebate incentive program.« less

  7. An automatic vision-based malaria diagnosis system.

    PubMed

    Vink, J P; Laubscher, M; Vlutters, R; Silamut, K; Maude, R J; Hasan, M U; DE Haan, G

    2013-06-01

    Malaria is a worldwide health problem with 225 million infections each year. A fast and easy-to-use method, with high performance is required to differentiate malaria from non-malarial fevers. Manual examination of blood smears is currently the gold standard, but it is time-consuming, labour-intensive, requires skilled microscopists and the sensitivity of the method depends heavily on the skills of the microscopist. We propose an easy-to-use, quantitative cartridge-scanner system for vision-based malaria diagnosis, focusing on low malaria parasite densities. We have used special finger-prick cartridges filled with acridine orange to obtain a thin blood film and a dedicated scanner to image the cartridge. Using supervised learning, we have built a Plasmodium falciparum detector. A two-step approach was used to first segment potentially interesting areas, which are then analysed in more detail. The performance of the detector was validated using 5,420 manually annotated parasite images from malaria parasite culture in medium, as well as using 40 cartridges of 11,780 images containing healthy blood. From finger prick to result, the prototype cartridge-scanner system gave a quantitative diagnosis in 16 min, of which only 1 min required manual interaction of basic operations. It does not require a wet lab or a skilled operator and provides parasite images for manual review and quality control. In healthy samples, the image analysis part of the system achieved an overall specificity of 99.999978% at the level of (infected) red blood cells, resulting in at most seven false positives per microlitre. Furthermore, the system showed a sensitivity of 75% at the cell level, enabling the detection of low parasite densities in a fast and easy-to-use manner. A field trial in Chittagong (Bangladesh) indicated that future work should primarily focus on improving the filling process of the cartridge and the focus control part of the scanner. © 2013 The Authors Journal of Microscopy © 2013 Royal Microscopical Society.

  8. 10 CFR 850 Implementation of Requirements

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Lee, S

    2012-01-05

    10 CFR 850 defines a contractor as any entity, including affiliated entities, such as a parent corporation, under contract with DOE, including a subcontractor at any tier, with responsibility for performing work at a DOE site in furtherance of a DOE mission. The Chronic Beryllium Disease Prevention Program (CBDPP) applies to beryllium-related activities that are performed at the Lawrence Livermore National Laboratory (LLNL). The CBDPP or Beryllium Safety Program is integrated into the LLNL Worker Safety and Health Program and, thus, implementation documents and responsibilities are integrated in various documents and organizational structures. Program development and management of the CBDPPmore » is delegated to the Environment, Safety and Health (ES&H) Directorate, Worker Safety and Health Functional Area. As per 10 CFR 850, Lawrence Livermore National Security, LLC (LLNS) periodically submits a CBDPP to the National Nuclear Security Administration/Livermore Site Office (NNSA/LSO). The requirements of this plan are communicated to LLNS workers through ES&H Manual Document 14.4, 'Working Safely with Beryllium.' 10 CFR 850 is implemented by the LLNL CBDPP, which integrates the safety and health standards required by the regulation, components of the LLNL Integrated Safety Management System (ISMS), and incorporates other components of the LLNL ES&H Program. As described in the regulation, and to fully comply with the regulation, specific portions of existing programs and additional requirements are identified in the CBDPP. The CBDPP is implemented by documents that interface with the workers, principally through ES&H Manual Document 14.4. This document contains information on how the management practices prescribed by the LLNL ISMS are implemented, how beryllium hazards that are associated with LLNL work activities are controlled, and who is responsible for implementing the controls. Adherence to the requirements and processes described in the ES&H Manual ensures that ES&H practices across LLNL are developed in a consistent manner. Other implementing documents, such as the ES&H Manual, are integral in effectively implementing 10 CFR 850.« less

  9. ESPVI 4.0 ELECTROSTATIS PRECIPITATOR V-1 AND PERFORMANCE MODEL: USER'S MANUAL

    EPA Science Inventory

    The manual is the companion document for the microcomputer program ESPVI 4.0, Electrostatic Precipitation VI and Performance Model. The program was developed to provide a user- friendly interface to an advanced model of electrostatic precipitation (ESP) performance. The program i...

  10. Manual, mechanical, and cultural control methds and tools

    Treesearch

    Steven Manning; James Miller

    2011-01-01

    There are many land management scenarios where chemicals are not the ideal choice for controlling invasive plants. More often than not, the best approach is the use of integrated pest management involving a variety of control methods. Maximizing the value of mechanical, manual, and cultural control methods with the added benefit of selective herbicides can offer the...

  11. Safe, Effective Use of Pesticides, A Manual for Commercial Applicators: Ornamental and Turf Pest Control.

    ERIC Educational Resources Information Center

    Extension Service (USDA), Washington, DC.

    This manual is intended to assist pesticide applicators in the area of ornamental and turf pest control prepare for certification under the Michigan Pesticide Control Act of 1976. The three sections presented describe: (1) Ornamentals; (2) Turfgrass; and (3) Pest Control. Section one discusses the diagnostic chart for plant problems, non-pest…

  12. 78 FR 41285 - Airworthiness Directives; Pilatus Aircraft Ltd. Airplanes

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-07-10

    ... manual). The limitations were revised to include an emergency fuel control system adjustment test. We are... a 300 Flight Hour (FH) hour inspection on the Emergency Fuel Control System (FCS). For the reason...., maintenance manual). The limitations were revised to include an emergency fuel control system adjustment test...

  13. 76 FR 46213 - National Standards for Traffic Control Devices; the Manual on Uniform Traffic Control Devices for...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-08-02

    ... design and application of traffic control devices, this Manual should not be considered a substitute for... retroreflectivity of longitudinal pavement markings. The deadline for comments to that docket has passed and the... the proposed revisions regarding maintaining minimum retroreflectivity of longitudinal pavement...

  14. Computer Numerical Control: Instructional Manual. The North Dakota High Technology Mobile Laboratory Project.

    ERIC Educational Resources Information Center

    Sinn, John W.

    This instructional manual contains five learning activity packets for use in a workshop on computer numerical control for computer-aided manufacturing. The lessons cover the following topics: introduction to computer-aided manufacturing, understanding the lathe, using the computer, computer numerically controlled part programming, and executing a…

  15. Cost Control. Michigan School Food Service Training Manual.

    ERIC Educational Resources Information Center

    Michigan State Univ., East Lansing. Cooperative Extension Service.

    Cost control is the subject of this eight-lesson, three-test food service training manual. Lesson 1 deals with financial accountability and includes 17 handouts, ranging from sample balance to quarterly report sheets. Lesson 2 focuses on budgeting principles, and lesson 3 on labor controls. Professional purchasing, receiving, and inventorying…

  16. Anaerobic Digestion. Student Manual. Biological Treatment Process Control.

    ERIC Educational Resources Information Center

    Carnegie, John W., Ed.

    This student manual contains the textual material for a four-lesson unit on anaerobic digestion control. Areas addressed include: (1) anaerobic sludge digestion (considering the nature of raw sludge, purposes of anaerobic digestion, the results of digestion, types of equipment, and other topics); (2) digester process control (considering feeding…

  17. Effects of exercise and manual therapy on pain associated with hip osteoarthritis: a systematic review and meta-analysis.

    PubMed

    Beumer, Lucy; Wong, Jennie; Warden, Stuart J; Kemp, Joanne L; Foster, Paul; Crossley, Kay M

    2016-04-01

    To explore the effects of exercise (water-based or land-based) and/or manual therapies on pain in adults with clinically and/or radiographically diagnosed hip osteoarthritis (OA). A systematic review and meta-analysis was performed, with patient reported pain assessed using a visual analogue scale (VAS) or the Western Ontario and McMaster Universities Arthritis Index (WOMAC) pain subscale. Data were grouped by follow-up time (0-3 months=short term; 4-12 months=medium term and; >12 months=long term), and standardised mean differences (SMD) with 95% CIs were used to establish intervention effect sizes. Study quality was assessed using modified PEDro scores. 19 trials were included. Four studies showed short-term benefits favouring water-based exercise over minimal control using the WOMAC pain subscale (SMD -0.53, 95% CI -0.96 to -0.10). Six studies supported a short-term benefit of land-based exercise compared to minimal control on VAS assessed pain (SMD -0.49, 95% CI -0.70 to -0.29). There were no medium (SMD -0.23, 95% CI -0.48 to 0.03) or long (SMD -0.22, 95% CI -0.51 to 0.06) term benefits of exercise therapy, or benefit of combining exercise therapy with manual therapy (SMD -0.38, 95% CI -0.88 to 0.13) when compared to minimal control. Best available evidence indicates that exercise therapy (whether land-based or water-based) is more effective than minimal control in managing pain associated with hip OA in the short term. Larger high-quality RCTs are needed to establish the effectiveness of exercise and manual therapies in the medium and long term. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://www.bmj.com/company/products-services/rights-and-licensing/

  18. Applicator Training Manual for: Public Health Pest Control.

    ERIC Educational Resources Information Center

    Moore, E. E.

    This manual gives the life cycle and habitats, public health importance, methods of non-chemical control, and pesticides and methods of application for mosquitoes, flies, bedbugs, fleas, lice, cockroaches, venomous anthropods, ticks and chiggers, and rodents. (BB)

  19. Forest Pest Control. Manual 94.

    ERIC Educational Resources Information Center

    Missouri Univ., Columbia. Agricultural Experiment Station.

    This training manual provides information needed to meet the minimum EPA standards for certification as a commercial applicator of pesticides in forest pest control. The text discusses disease problems, insects, and herbicide use in both established forests and nurseries. (CS)

  20. Dispelling Rumours Around Zika and Complications

    MedlinePlus

    ... the spread and control of disease. WHO’s Vector Control Advisory Group is preparing a manual on how best to design such studies. The manual will be released later this year. ... populations. WHO encourages affected countries and their ...

  1. 46 CFR 161.002-12 - Manual fire alarm systems.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    .... (a) General. A manual fire alarm system shall consist of a power supply, a control unit on which are... using manually operated fire alarm boxes. (3) Other types as may be developed. (c) Power supply. The power supply shall be as specified for automatic fire detecting system by § 161.002-9. (d) Manual fire...

  2. 46 CFR 161.002-12 - Manual fire alarm systems.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    .... (a) General. A manual fire alarm system shall consist of a power supply, a control unit on which are... using manually operated fire alarm boxes. (3) Other types as may be developed. (c) Power supply. The power supply shall be as specified for automatic fire detecting system by § 161.002-9. (d) Manual fire...

  3. Launch Vehicle Manual Steering with Adaptive Augmenting Control In-flight Evaluations of Adverse Interactions Using a Piloted Aircraft

    NASA Technical Reports Server (NTRS)

    Hanson, Curt; Miller, Chris; Wall, John H.; Vanzwieten, Tannen S.; Gilligan, Eric; Orr, Jeb S.

    2015-01-01

    An adaptive augmenting control algorithm for the Space Launch System has been developed at the Marshall Space Flight Center as part of the launch vehicles baseline flight control system. A prototype version of the SLS flight control software was hosted on a piloted aircraft at the Armstrong Flight Research Center to demonstrate the adaptive controller on a full-scale realistic application in a relevant flight environment. Concerns regarding adverse interactions between the adaptive controller and a proposed manual steering mode were investigated by giving the pilot trajectory deviation cues and pitch rate command authority. Two NASA research pilots flew a total of twenty five constant pitch-rate trajectories using a prototype manual steering mode with and without adaptive control.

  4. Strength training alone, exercise therapy alone, and exercise therapy with passive manual mobilisation each reduce pain and disability in people with knee osteoarthritis: a systematic review.

    PubMed

    Jansen, Mariette J; Viechtbauer, Wolfgang; Lenssen, Antoine F; Hendriks, Erik J M; de Bie, Rob A

    2011-01-01

    What are the effects of strength training alone, exercise therapy alone, and exercise with additional passive manual mobilisation on pain and function in people with knee osteoarthritis compared to control? What are the effects of these interventions relative to each other? A meta-analysis of randomised controlled trials. Adults with osteoarthritis of the knee. INTERVENTION TYPES: Strength training alone, exercise therapy alone (combination of strength training with active range of motion exercises and aerobic activity), or exercise with additional passive manual mobilisation, versus any non-exercise control. Comparisons between the three interventions were also sought. The primary outcome measures were pain and physical function. 12 trials compared one of the interventions against control. The effect size on pain was 0.38 (95% CI 0.23 to 0.54) for strength training, 0.34 (95% CI 0.19 to 0.49) for exercise, and 0.69 (95% CI 0.42 to 0.96) for exercise plus manual mobilisation. Each intervention also improved physical function significantly. No randomised comparisons of the three interventions were identified. However, meta-regression indicated that exercise plus manual mobilisations improved pain significantly more than exercise alone (p = 0.03). The remaining comparisons between the three interventions for pain and physical function were not significant. Exercise therapy plus manual mobilisation showed a moderate effect size on pain compared to the small effect sizes for strength training or exercise therapy alone. To achieve better pain relief in patients with knee osteoarthritis physiotherapists or manual therapists might consider adding manual mobilisation to optimise supervised active exercise programs. Copyright © 2011 Australian Physiotherapy Association. Published by .. All rights reserved.

  5. Application of the 3D slicer chest imaging platform segmentation algorithm for large lung nodule delineation

    PubMed Central

    Parmar, Chintan; Blezek, Daniel; Estepar, Raul San Jose; Pieper, Steve; Kim, John; Aerts, Hugo J. W. L.

    2017-01-01

    Purpose Accurate segmentation of lung nodules is crucial in the development of imaging biomarkers for predicting malignancy of the nodules. Manual segmentation is time consuming and affected by inter-observer variability. We evaluated the robustness and accuracy of a publically available semiautomatic segmentation algorithm that is implemented in the 3D Slicer Chest Imaging Platform (CIP) and compared it with the performance of manual segmentation. Methods CT images of 354 manually segmented nodules were downloaded from the LIDC database. Four radiologists performed the manual segmentation and assessed various nodule characteristics. The semiautomatic CIP segmentation was initialized using the centroid of the manual segmentations, thereby generating four contours for each nodule. The robustness of both segmentation methods was assessed using the region of uncertainty (δ) and Dice similarity index (DSI). The robustness of the segmentation methods was compared using the Wilcoxon-signed rank test (pWilcoxon<0.05). The Dice similarity index (DSIAgree) between the manual and CIP segmentations was computed to estimate the accuracy of the semiautomatic contours. Results The median computational time of the CIP segmentation was 10 s. The median CIP and manually segmented volumes were 477 ml and 309 ml, respectively. CIP segmentations were significantly more robust than manual segmentations (median δCIP = 14ml, median dsiCIP = 99% vs. median δmanual = 222ml, median dsimanual = 82%) with pWilcoxon~10−16. The agreement between CIP and manual segmentations had a median DSIAgree of 60%. While 13% (47/354) of the nodules did not require any manual adjustment, minor to substantial manual adjustments were needed for 87% (305/354) of the nodules. CIP segmentations were observed to perform poorly (median DSIAgree≈50%) for non-/sub-solid nodules with subtle appearances and poorly defined boundaries. Conclusion Semi-automatic CIP segmentation can potentially reduce the physician workload for 13% of nodules owing to its computational efficiency and superior stability compared to manual segmentation. Although manual adjustment is needed for many cases, CIP segmentation provides a preliminary contour for physicians as a starting point. PMID:28594880

  6. Effect of a worktable position on head and shoulder posture and shoulder muscles in manual material handling.

    PubMed

    Kim, Min-Hee; Yoo, Won-Gyu

    2015-06-05

    According to a recent research, manual working with high levels of static contraction, repetitive loads, or extreme working postures involving the neck and shoulder muscles causes an increased risk of neck and shoulder musculoskeletal disorders. We investigated the effects of the forwardly worktable position on head and shoulder angles and shoulder muscle activity in manual material handling tasks. The forward head and shoulder angles and the activity of upper trapezius, levator scapulae, and middle deltoid muscle activities of 15 workers were measured during performing of manual material handling in two tasks that required different forward head and shoulder angles. The second manual material task required a significantly increased forward head and shoulder angle. The upper trapezius and levator scapulae muscle activity in second manual material task was increased significantly compared with first manual material task. The middle deltoid muscle activity in second manual material task was not significantly different compared with first manual material task. Based on this result, the forward head and shoulder angles while performing manual work need to be considered in selection of the forward distance of a worktable form the body. The high level contractions of the neck and shoulder muscles correlated with neck and shoulder pain. Therefore, the forward distance of a worktable can be an important factor in preventing neck and shoulder pain in manual material handling workers.

  7. Evaluation of induction motor performance using an electronic power factor controller

    NASA Technical Reports Server (NTRS)

    1978-01-01

    The concept of reducing the losses in an induction motor by electronically controlling the time interval between the zero crossing of the applied voltage and the zero crossing of the armature current was evaluated. The effect on power losses and power factor of reducing the applied sinusoidal voltages below the rated value was investigated experimentally. The reduction in power losses was measured using an electronic controller designed and built at MSFC. Modifications to the MSFC controller are described as well as a manually controlled electronic device which does not require that the motor be wye connected and the neutral available. Possible energy savings are examined.

  8. Longitudinal development of manual motor ability in autism spectrum disorder from childhood to mid-adulthood relates to adaptive daily living skills.

    PubMed

    Travers, Brittany G; Bigler, Erin D; Duffield, Tyler C; Prigge, Molly D B; Froehlich, Alyson L; Lange, Nicholas; Alexander, Andrew L; Lainhart, Janet E

    2017-07-01

    Many individuals with autism spectrum disorder (ASD) exhibit motor difficulties, but it is unknown whether manual motor skills improve, plateau, or decline in ASD in the transition from childhood into adulthood. Atypical development of manual motor skills could impact the ability to learn and perform daily activities across the life span. This study examined longitudinal grip strength and finger tapping development in individuals with ASD (n = 90) compared to individuals with typical development (n = 56), ages 5 to 40 years old. We further examined manual motor performance as a possible correlate of current and future daily living skills. The group with ASD demonstrated atypical motor development, characterized by similar performance during childhood but increasingly poorer performance from adolescence into adulthood. Grip strength was correlated with current adaptive daily living skills, and Time 1 grip strength predicted daily living skills eight years into the future. These results suggest that individuals with ASD may experience increasingly more pronounced motor difficulties from adolescence into adulthood and that manual motor performance in ASD is related to adaptive daily living skills. © 2016 John Wiley & Sons Ltd.

  9. 1999 commuter assistance program evaluation manual

    DOT National Transportation Integrated Search

    2001-01-01

    This manual was developed to assist Florida's Commuter Assistance Programs (CAP) to measure and evaluate their performance. It provides information necessary for a CAP to create and implement its own evaluation program. It discusses performance measu...

  10. Detection of system failures in multi-axes tasks. [pilot monitored instrument approach

    NASA Technical Reports Server (NTRS)

    Ephrath, A. R.

    1975-01-01

    The effects of the pilot's participation mode in the control task on his workload level and failure detection performance were examined considering a low visibility landing approach. It is found that the participation mode had a strong effect on the pilot's workload, the induced workload being lowest when the pilot acted as a monitoring element during a coupled approach and highest when the pilot was an active element in the control loop. The effects of workload and participation mode on failure detection were separated. The participation mode was shown to have a dominant effect on the failure detection performance, with a failure in a monitored (coupled) axis being detected significantly faster than a comparable failure in a manually controlled axis.

  11. The Effects of Spaceflight on Neurocognitive Performance: Extent, Longevity, and Neural Bases

    NASA Technical Reports Server (NTRS)

    Seidler, Rachael D.; Bloomberg, Jacob; Wood, Scott; Mason, Sara; Mulavara, Ajit; Kofman, Igor; De Dios, Yiri; Gadd, Nicole; Stepanyan, Vahagn; Szecsy, Darcy

    2017-01-01

    Spaceflight effects on gait, balance, & manual motor control have been well studied; some evidence for cognitive deficits. Rodent cortical motor & sensory systems show neural structural alterations with spaceflight. We found extensive changes in behavior, brain structure & brain function following 70 days of HDBR. Specific Aim: Aim 1-Identify changes in brain structure, function, and network integrity as a function of spaceflight and characterize their time course. Aim 2-Specify relationships between structural and functional brain changes and performance and characterize their time course.

  12. The Effects of Spaceflight and Head Down Tilt Bed Rest on Neurocognitive Performance: Extent, Longevity, and Neural Bases

    NASA Technical Reports Server (NTRS)

    Seidler, Rachael D.; Bloomberg, Jacob; Wood, Scott; Mulavara, Ajit; Kofman, Igor; De Dios, Yiri; Gadd, Nicole; Stepanyan, Vahagn

    2017-01-01

    Spaceflight effects on gait, balance, & manual motor control have been well studied; some evidence for cognitive deficits. Rodent cortical motor & sensory systems show neural structural alterations with spaceflight. specific Aims: Aim 1-Identify changes in brain structure, function, and network integrity as a function of head down tilt bed rest and spaceflight, and characterize their time course. Aim 2-Specify relationships between structural and functional brain changes and performance and characterize their time course.

  13. Stinger Post Hybrid Simulation: Design Description and Users’ Manual

    DTIC Science & Technology

    1983-04-01

    function of three variables. Table 4 MVFG Modes £ ?*" Mode Function Number Argument Number Trunking Station Address Output Hole Argument...between JA and J7. This permits the signal to control a normally-open, single-throw minature relay. It closes the remote operate line when a logic...logic functions are also performed on the card. A normally- open, single-throw minature relay (U5) and an AND gate (1/4 of Ul) are used to perform the

  14. Physiologic parameters associated with sexual arousal in women with incomplete spinal cord injuries.

    PubMed

    Sipski, M L; Alexander, C J; Rosen, R C

    1997-03-01

    To compare the physiologic sexual responses of women with incomplete spinal cord injuries (SCIs) with and without preservation of the ability to perceive T11-L2 pinprick sensation. Controlled laboratory-based analysis of responses to varying combinations of audiovisual erotic stimulation, manual genital stimulation, and performance of a distracting task coupled with manual genital stimulation. The sexual physiology laboratory at our freestanding rehabilitation hospital. A volunteer sample of 17 women with incomplete SCIs. Two 78-minute protocols using 6-minute baselines alternating with 12-minute testing conditions. One protocol was designed to study the effects of psychogenic and psychogenic combined with manual sexual stimulation, while the other was designed to examine the effects of genital sexual stimulation performed in conjunction with a distracting task. Vaginal pulse amplitude, subjective arousal, heart rate, respiratory rate, and blood pressure. Subjective arousal increased in both groups of subjects with isolated audiovisual erotic stimulation; however, only those subjects with the ability to perceive T11-L2 pinprick sensation had concomitant increases in vaginal pulse amplitude. In contrast, when manual genital stimulation was added to the audiovisual erotic stimulation, both groups of subjects developed increases in vaginal pulse amplitude, whereas only those subjects with the ability to perceive T11-L2 demonstrated a further increase in their level of subjective arousal. Performance of manual genital stimulation in conjunction with a distracting task resulted in significantly increased vaginal pulse amplitude and arousal level only in those subjects with preservation of the ability to perceive T11-L2 pinprick sensation. With the changeover to masturbation, neither group of subjects developed significant increases in vaginal pulse amplitude. During masturbation, both groups of subjects had increases in their level of sexual arousal; however, only those subjects with T11-L2 pinprick preservation had a significant increase. Women with preservation of the ability to perceive T11-L2 pinprick sensation tended to maintain the ability for psychogenic genital vasocongestion. Psychogenic protocol results showed that all subjects appeared to develop reflex genital vasocongestion when manual stimulation was added to audiovisual erotic stimulation. Manual genital stimulation in conjunction with the performance of a distracting task only resulted in increased vaginal pulse amplitudes in those subjects with preservation of T11-L2 pinprick sensation. We believe that this was due to increased subjective sexual arousal and that the reason all subjects did not develop increased genital vasocongestion under these conditions was due to poor hand function. Further research examining women with lower levels of SCI is necessary to understand the neurophysiology of female sexual response after SCI.

  15. Effect of manual therapy versus proprioceptive neuromuscular facilitation in dynamic balance, mobility and flexibility in field hockey players. A randomized controlled trial.

    PubMed

    Espí-López, Gemma V; López-Martínez, Susana; Inglés, Marta; Serra-Añó, Pilar; Aguilar-Rodríguez, Marta

    2018-04-22

    To compare the effectiveness of a specific Manual Therapy (MT) protocol applied to field hockey players (FHP), versus a Proprioceptive Neuromuscular Facilitation (PNF) protocol, in the improvement of dynamic balance, active range of movement and lumbar flexibility one-week and four-weeks after the treatment. Randomized controlled trial. Participants were assigned to 2 groups: MT and PNF. 30 min' sessions were performed once a week for three weeks. Three evaluations were performed: basal, one-week and four-weeks post-treatment. University of Valencia (Spain). 22 in MT group and 20 in PNF group. Dynamic Balance, measured with Star Excursion Balance Test; Active Range of Motion (ROM), using a manual goniometer and Lumbar Flexibility, assessed with Fingertip-to-floor test. Both groups significantly improved in lateral and medial dynamic balance one-week post-treatment (p < 0.05); but the improvement in the MT group lasted until the fourth-week after treatment in both reaches (lateral and medial) (p < 0.05). MT group also obtained significant improvements in dorsal flexion of the ankle in the fourth-week post-treatment (p < 0.05) and in lumbar flexibility one-week post-treatment (p < 0.05). MT and PNF improve dynamic balance one-week post-treatment; however, the improvement obtained through MT is maintained four-weeks later. Only MT improves dorsal flexion of the ankle four-weeks post-treatment and lumbar flexibility one-week post-treatment. Copyright © 2018 Elsevier Ltd. All rights reserved.

  16. Steady-state evoked potentials possibilities for mental-state estimation

    NASA Technical Reports Server (NTRS)

    Junker, Andrew M.; Schnurer, John H.; Ingle, David F.; Downey, Craig W.

    1988-01-01

    The use of the human steady-state evoked potential (SSEP) as a possible measure of mental-state estimation is explored. A method for evoking a visual response to a sum-of-ten sine waves is presented. This approach provides simultaneous multiple frequency measurements of the human EEG to the evoking stimulus in terms of describing functions (gain and phase) and remnant spectra. Ways in which these quantities vary with the addition of performance tasks (manual tracking, grammatical reasoning, and decision making) are presented. Models of the describing function measures can be formulated using systems engineering technology. Relationships between model parameters and performance scores during manual tracking are discussed. Problems of unresponsiveness and lack of repeatability of subject responses are addressed in terms of a need for loop closure of the SSEP. A technique to achieve loop closure using a lock-in amplifier approach is presented. Results of a study designed to test the effectiveness of using feedback to consciously connect humans to their evoked response are presented. Findings indicate that conscious control of EEG is possible. Implications of these results in terms of secondary tasks for mental-state estimation and brain actuated control are addressed.

  17. AEOSS runtime manual for system analysis on Advanced Earth-Orbital Spacecraft Systems

    NASA Technical Reports Server (NTRS)

    Lee, Hwa-Ping

    1990-01-01

    Advanced earth orbital spacecraft system (AEOSS) enables users to project the required power, weight, and cost for a generic earth-orbital spacecraft system. These variables are calculated on the component and subsystem levels, and then the system level. The included six subsystems are electric power, thermal control, structure, auxiliary propulsion, attitude control, and communication, command, and data handling. The costs are computed using statistically determined models that were derived from the flown spacecraft in the past and were categorized into classes according to their functions and structural complexity. Selected design and performance analyses for essential components and subsystems are also provided. AEOSS has the feature permitting a user to enter known values of these parameters, totally and partially, at all levels. All information is of vital importance to project managers of subsystems or a spacecraft system. AEOSS is a specially tailored software coded from the relational database program of the Acius' 4th Dimension with a Macintosh version. Because of the licensing agreements, two versions of the AEOSS documents were prepared. This version, AEOSS Runtime Manual, is permitted to be distributed with a finite number of the restrictive 4D Runtime version. It can perform all contained applications without any programming alterations.

  18. 26. DETAIL VIEW OF THE ADJUSTABLE FIELD RESISTTOR MANUAL CONTROLS ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    26. DETAIL VIEW OF THE ADJUSTABLE FIELD RESISTTOR MANUAL CONTROLS AND SWITCH BOXES. - Potomac Power Plant, On West Virginia Shore of Potomac River, about 1 mile upriver from confluence with Shenandoah River, Harpers Ferry, Jefferson County, WV

  19. 75 FR 72822 - Nationwide Categorical Waivers Under Section 1605 (Buy American) of the American Recovery and...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-11-26

    ... a temperature range of 15-55 degrees Fahrenheit and manual reset; (4) Programmable DDC controllers... manual reset; (4) Programmable DDC controllers for LON protocol, where an existing LON system exists that...

  20. Review of manual control methods for handheld maneuverable instruments.

    PubMed

    Fan, Chunman; Dodou, Dimitra; Breedveld, Paul

    2013-06-01

    By the introduction of new technologies, surgical procedures have been varying from free access in open surgery towards limited access in minimal access surgery. Improving access to difficult-to-reach anatomic sites, e.g. in neurosurgery or percutaneous interventions, needs advanced maneuverable instrumentation. Advances in maneuverable technology require the development of dedicated methods enabling surgeons to stay in direct, manual control of these complex instruments. This article gives an overview of the state-of-the-art in the development of manual control methods for handheld maneuverable instruments. It categorizes the manual control methods in three levels: a) number of steerable segments, b) number of Degrees Of Freedom (DOF), and c) coupling between control motion of the handle and steering motion of the tip. The literature research was completed by using Web of Science, Scopus and PubMed. The study shows that in controlling single steerable segments, direct as well as indirect control methods have been developed, whereas in controlling multiple steerable segments, a gradual shift can be noticed from parallel and serial control to integrated control. The development of multi-segmented maneuverable instruments is still at an early stage, and an intuitive and effective method to control them has to become a primary focus in the domain of minimal access surgery.

  1. Anticipatory control: A software retrofit for current plant controllers

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Parthasarathy, S.; Parlos, A.G.; Atiya, A.F.

    1993-01-01

    The design and simulated testing of an artificial neural network (ANN)-based self-adapting controller for complex process systems are presented in this paper. The proposed controller employs concepts based on anticipatory systems, which have been widely used in the petroleum and chemical industries, and they are slowly finding their way into the power industry. In particular, model predictive control (MPC) is used for the systematic adaptation of the controller parameters to achieve desirable plant performance over the entire operating envelope. The versatile anticipatory control algorithm developed in this study is projected to enhance plant performance and lend robustness to drifts inmore » plant parameters and to modeling uncertainties. This novel technique of integrating recurrent ANNs with a conventional controller structure appears capable of controlling complex, nonlinear, and nonminimum phase process systems. The direct, on-line adaptive control algorithm presented in this paper considers the plant response over a finite time horizon, diminishing the need for manual control or process interruption for controller gain tuning.« less

  2. A study on special test stand of automatic and manual descent control in presence of simulated g-load effect

    NASA Astrophysics Data System (ADS)

    Glazkov, Yury; Artjuchin, Yury; Astakhov, Alexander; Vas'kov, Alexander; Malyshev, Veniamin; Mitroshin, Edward; Glinsky, Valery; Moiseenko, Vasily; Makovlev, Vyacheslav

    The development of aircraft-type reusable space vehicles (RSV) involves the problem of complete compatibility of automatic, director and manual control. Task decision is complicated, in particular, due to considerable quantitative and qualitative changes of vehicle dynamic characteristics, little stability margins (and even of unstability) of the RSV, and stringent requirements to control accuracy at some flight phases. Besides, during control a pilot is affected by g-loads which hamper motor activity and deteriorate its accuracy, alter the functional status of the visual analyser, and influence higher nervous activity. A study of g-load effects on the control efficiency, especially in manual and director modes, is of primary importance. The main tools for study of a rational selection of manual and director vehicle control systems and as an aid in formulating recommendations for optimum crew-automatic control system interactions are special complex and functional flight simulator test stands. The proposed simulator stand includes a powerful digital computer complex combined with the control system of the centrifuge. The interior of a pilot's vehicle cabin is imitated. A situation image system, pyscho-physical monitoring system, physician, centrifuge operator, and instructor stations are linked with the test stand.

  3. 46 CFR 160.176-19 - Servicing.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... section contains requirements for servicing facilities, manuals, training, guidelines, and records. Other... follow the procedures in the service manual required by this section. (2) Each servicing facility must... strong sunlight, and have appropriate temperature and humidity control as specified in the service manual...

  4. A comparison of treatment effectiveness between the CAD/CAM method and the manual method for managing adolescent idiopathic scoliosis.

    PubMed

    Wong, M S; Cheng, J C Y; Lo, K H

    2005-04-01

    The treatment effectiveness of the CAD/CAM method and the manual method in managing adolescent idiopathic scoliosis (AIS) was compared. Forty subjects were recruited with twenty subjects for each method. The clinical parameters namely Cobb's angle and apical vertebral rotation were evaluated at the pre-brace and the immediate in-brace visits. The results demonstrated that orthotic treatments rendered by the CAD/CAM method and the conventional manual method were effective in providing initial control of Cobb's angle. Significant decreases (p < 0.05) were found between the pre-brace and immediate in-brace visits for both methods. The mean reductions of Cobb's angle were 12.8 degrees (41.9%) for the CAD/CAM method and 9.8 degrees (32.1%) for the manual method. An initial control of the apical vertebral rotation was not shown in this study. In the comparison between the CAD/CAM method and the manual method, no significant difference was found in the control of Cobb's angle and apical vertebral rotation. The current study demonstrated that the CAD/CAM method can provide similar result in the initial stage of treatment as compared with the manual method.

  5. Surface Environmental Surveillance Procedures Manual

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Hanf, RW; Dirkes, RL

    1990-02-01

    This manual establishes the procedures for the collection of environmental samples and the performance of radiation surveys and other field measurements. Responsibilities are defined for those personnel directly involved in the collection of samples and the performance of field measurements.

  6. Long-term pavement performance program manual for profile measurements and processing

    DOT National Transportation Integrated Search

    2008-11-01

    This manual describes operational procedures for measuring longitudinal pavement profiles for the Long-Term Pavement Performance (LTPP) Program using the International Cybernetics Corporation (ICC) road profiler, Face Company Dipstick, and the rod an...

  7. Decrement in manual arm performance during whole body cooling.

    PubMed

    Giesbrecht, G G; Bristow, G K

    1992-12-01

    Six subjects performed three manual arm tasks: 1) prior to immersion in 8 degrees C water; 2) soon after immersion to the neck, but prior to any decrease in core temperature; and 3) every 15 min until core temperatures decreased 2-4.5 degrees C. The tasks were speed of flexion and extension of the fingers, handgrip strength and manual dexterity. There was no immediate effect of cold immersion; however, all scores decreased significantly after core temperature decreased 0.5 degrees C. Further decrease in core temperature was associated with a progressive impairment of performance, although at a slower rate than during the first 0.5 degrees C decrease. Flexion and extension of the fingers was affected relatively more than handgrip strength or manual dexterity. Decrement in performance is a result of peripheral cooling on sensorimotor function with a probable additional effect of central cooling on cerebral function.

  8. 18 CFR 3b.204 - Safeguarding information in manual and computer-based record systems.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... information in manual and computer-based record systems. 3b.204 Section 3b.204 Conservation of Power and Water... Collection of Records § 3b.204 Safeguarding information in manual and computer-based record systems. (a) The administrative and physical controls to protect the information in the manual and computer-based record systems...

  9. 18 CFR 3b.204 - Safeguarding information in manual and computer-based record systems.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... information in manual and computer-based record systems. 3b.204 Section 3b.204 Conservation of Power and Water... Collection of Records § 3b.204 Safeguarding information in manual and computer-based record systems. (a) The administrative and physical controls to protect the information in the manual and computer-based record systems...

  10. 18 CFR 3b.204 - Safeguarding information in manual and computer-based record systems.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... information in manual and computer-based record systems. 3b.204 Section 3b.204 Conservation of Power and Water... Collection of Records § 3b.204 Safeguarding information in manual and computer-based record systems. (a) The administrative and physical controls to protect the information in the manual and computer-based record systems...

  11. 18 CFR 3b.204 - Safeguarding information in manual and computer-based record systems.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... information in manual and computer-based record systems. 3b.204 Section 3b.204 Conservation of Power and Water... Collection of Records § 3b.204 Safeguarding information in manual and computer-based record systems. (a) The administrative and physical controls to protect the information in the manual and computer-based record systems...

  12. Action-perception dissociation in response to target acceleration.

    PubMed

    Dubrowski, Adam; Carnahan, Heather

    2002-05-01

    The purpose of this study was to investigate whether information about the acceleration characteristics of a moving target can be used for both action and perception. Also of interest was whether prior movement experience altered perceptual judgements. Participants manually intercepted targets moving with various acceleration, velocity and movement time characteristics. They also made perceptual judgements about the acceleration characteristics of these targets either with or without prior manual interception experience. Results showed that while aiming kinematics were sensitive to the acceleration characteristics of the target, participants were only able to perceptually discriminate the velocity characteristics of target motion, even after performing interceptive actions to the same targets. These results are discussed in terms of a two channel (action-perception) model of visuomotor control.

  13. Flexible and composite structures for premium pavements. Volume 2, Design manual

    DOT National Transportation Integrated Search

    1980-11-01

    This design manual presents the results of a detailed study to identify and design flexible and composite pavement configurations which will perform as premium or "zero-maintenance" pavements. This manual includes identification and classification of...

  14. Single axis control of ball position in magnetic levitation system using fuzzy logic control

    NASA Astrophysics Data System (ADS)

    Sahoo, Narayan; Tripathy, Ashis; Sharma, Priyaranjan

    2018-03-01

    This paper presents the design and real time implementation of Fuzzy logic control(FLC) for the control of the position of a ferromagnetic ball by manipulating the current flowing in an electromagnet that changes the magnetic field acting on the ball. This system is highly nonlinear and open loop unstable. Many un-measurable disturbances are also acting on the system, making the control of it highly complex but interesting for any researcher in control system domain. First the system is modelled using the fundamental laws, which gives a nonlinear equation. The nonlinear model is then linearized at an operating point. Fuzzy logic controller is designed after studying the system in closed loop under PID control action. The controller is then implemented in real time using Simulink real time environment. The controller is tuned manually to get a stable and robust performance. The set point tracking performance of FLC and PID controllers were compared and analyzed.

  15. Identification of spinal tissues loaded by manual therapy: a robot-based serial dissection technique applied in porcine motion segments.

    PubMed

    Kawchuk, Gregory N; Carrasco, Alejandro; Beecher, Grayson; Goertzen, Darrell; Prasad, Narasimha

    2010-10-15

    Serial dissection of porcine motion segments during robotic control of vertebral kinematics. To identify which spinal tissues are loaded in response to manual therapy (manipulation and mobilization) and to what magnitude. Various theoretical constructs attempt to explain how manual therapies load specific spinal tissues. By using a parallel robot to control vertebral kinematics during serial dissection, it is possible to quantify the loads experienced by discrete spinal tissues undergoing common therapeutic procedures such as manual therapy. In 9 porcine cadavers, manual therapy was provided to L3 and the kinematic response of L3-L4 recorded. The exact kinematic trajectory experienced by L3-L4 in response to manual therapy was then replayed to the isolated segment by a parallel robot equipped with a 6-axis load cell. Discrete spinal tissues were then removed and the kinematic pathway replayed. The change in forces and moments following tissue removal were considered to be those applied to that specific tissue by manual therapy. In this study, both manual therapies affected spinal tissues. The intervertebral disc experienced the greatest forces and moments arising from both manipulation and mobilization. This study is the first to identify which tissues are loaded in response to manual therapy. The observation that manual therapy loads some tissues to a much greater magnitude than others offers a possible explanation for its modest treatment effect; only conditions involving these tissues may be influenced by manual therapy. Future studies are planned to determine if manual therapy can be altered to target (or avoid) specific spinal tissues.

  16. Evaluation of dexterity in insulin-treated patients with type 1 and type 2 diabetes mellitus.

    PubMed

    Pfützner, Julia; Hellhammer, Juliane; Musholt, Petra; Pfützner, Anke H; Böhnke, Jan; Torsten, Hero; Amann-Zalan, Ildiko; Ganz, Manfred; Forst, Thomas; Pfützner, Andreas

    2011-01-01

    Daily routine for insulin-treated patients with diabetes mellitus requires correct performance of self-monitoring of blood glucose and insulin injections several times a day. Dexterity skills may play an important role in the performance efficacy of these procedures. We collected data of insulin-treated (>10 years) patients with different age ranges [healthy controls, 14 female/11 male, age (mean ± standard deviation) 55 ± 7 years; type 1 diabetes mellitus (T1DM) patients, 12/13, 45 ± 9 years, disease duration 23.9 ± 6.5 years; T2DM patients, 8/17, 64 ± 6 years, 16.2 ± 6.9 years; T2DM patients (>70 years of age), 9/16, 75 ± 4 years, 19.7 ± 7.0 years]. After assessment of neuropathy (temperature, pain, and vibration perception), the patients participated in two dexterity test batteries [Jebsen-Taylor hand-function test (JHFT) and motoric performance series (MPS)]. Patients with type 2 diabetes showed disturbed vibration perception as compared to the other groups. The dexterity results were influenced by age to a large extent. Older T2DM patients performed worst in the majority of the subtests (e.g., JHFT, writing nondominant hand: control, 40.8 ± 11.7 s; T1DM, 46.3 ± 50.9 s, not significant versus control; old T2DM, 68.1 ± 29.5 s, p < .05; young T2DM, 52.5 ± 26.2 s, p < .05). Patients with type 1 diabetes showed similar JHFT and MPS results than the 10-year-older control subjects and performed outside of the age-dependent normal reference range. Manual skills and dexterity differed between the groups, and age-corrected reduced skills were common in both T1DM and T2DM patients in this study. Our findings underline the importance of considering dexterity and manual skills when designing medical devices for patients with diabetes mellitus. © 2010 Diabetes Technology Society.

  17. Investigation of Control System and Display Variations on Spacecraft Handling Qualities for Docking with Stationary and Rotating Targets

    NASA Technical Reports Server (NTRS)

    Jackson, E. Bruce; Goodrich, Kenneth H.; Bailey, Randall E.; Barnes, James R.; Ragsdale, William A.; Neuhaus, Jason R.

    2010-01-01

    This paper documents the investigation into the manual docking of a preliminary version of the Crew Exploration Vehicle with stationary and rotating targets in Low Earth Orbit. The investigation was conducted at NASA Langley Research Center in the summer of 2008 in a repurposed fixed-base transport aircraft cockpit and involved nine evaluation astronauts and research pilots. The investigation quantified the benefits of a feed-forward reaction control system thruster mixing scheme to reduce translation-into-rotation coupling, despite unmodeled variations in individual thruster force levels and off-axis center of mass locations up to 12 inches. A reduced rate dead-band in the phase-plane attitude controller also showed some promise. Candidate predictive symbology overlaid on a docking ring centerline camera image did not improve handling qualities, but an innovative attitude status indicator symbol was beneficial. The investigation also showed high workload and handling quality problems when manual dockings were performed with a rotating target. These concerns indicate achieving satisfactory handling quality ratings with a vehicle configuration similar to the nominal Crew Exploration Vehicle may require additional automation.

  18. A New Semi-Automatic Approach to Find Suitable Virtual Electrodes in Arrays Using an Interpolation Strategy.

    PubMed

    Salchow, Christina; Valtin, Markus; Seel, Thomas; Schauer, Thomas

    2016-06-13

    Functional Electrical Stimulation via electrode arrays enables the user to form virtual electrodes (VEs) of dynamic shape, size, and position. We developed a feedback-control-assisted manual search strategy which allows the therapist to conveniently and continuously modify VEs to find a good stimulation area. This works for applications in which the desired movement consists of at least two degrees of freedom. The virtual electrode can be moved to arbitrary locations within the array, and each involved element is stimulated with an individual intensity. Meanwhile, the applied global stimulation intensity is controlled automatically to meet a predefined angle for one degree of freedom. This enables the therapist to concentrate on the remaining degree(s) of freedom while changing the VE position. This feedback-control-assisted approach aims to integrate the user's opinion and the patient's sensation. Therefore, our method bridges the gap between manual search and fully automatic identification procedures for array electrodes. Measurements in four healthy volunteers were performed to demonstrate the usefulness of our concept, using a 24-element array to generate wrist and hand extension.

  19. Semiautomated spleen volumetry with diffusion-weighted MR imaging.

    PubMed

    Lee, Jeongjin; Kim, Kyoung Won; Lee, Ho; Lee, So Jung; Choi, Sanghyun; Jeong, Woo Kyoung; Kye, Heewon; Song, Gi-Won; Hwang, Shin; Lee, Sung-Gyu

    2012-07-01

    In this article, we determined the relative accuracy of semiautomated spleen volumetry with diffusion-weighted (DW) MR images compared to standard manual volumetry with DW-MR or CT images. Semiautomated spleen volumetry using simple thresholding followed by 3D and 2D connected component analysis was performed with DW-MR images. Manual spleen volumetry was performed on DW-MR and CT images. In this study, 35 potential live liver donor candidates were included. Semiautomated volumetry results were highly correlated with manual volumetry results using DW-MR (r = 0.99; P < 0.0001; mean percentage absolute difference, 1.43 ± 0.94) and CT (r = 0.99; P < 0.0001; 1.76 ± 1.07). Mean total processing time for semiautomated volumetry was significantly shorter compared to that of manual volumetry with DW-MR (P < 0.0001) and CT (P < 0.0001). In conclusion, semiautomated spleen volumetry with DW-MR images can be performed rapidly and accurately when compared with standard manual volumetry. Copyright © 2011 Wiley Periodicals, Inc.

  20. From mouth to hand: gesture, speech, and the evolution of right-handedness.

    PubMed

    Corballis, Michael C

    2003-04-01

    The strong predominance of right-handedness appears to be a uniquely human characteristic, whereas the left-cerebral dominance for vocalization occurs in many species, including frogs, birds, and mammals. Right-handedness may have arisen because of an association between manual gestures and vocalization in the evolution of language. I argue that language evolved from manual gestures, gradually incorporating vocal elements. The transition may be traced through changes in the function of Broca's area. Its homologue in monkeys has nothing to do with vocal control, but contains the so-called "mirror neurons," the code for both the production of manual reaching movements and the perception of the same movements performed by others. This system is bilateral in monkeys, but predominantly left-hemispheric in humans, and in humans is involved with vocalization as well as manual actions. There is evidence that Broca's area is enlarged on the left side in Homo habilis, suggesting that a link between gesture and vocalization may go back at least two million years, although other evidence suggests that speech may not have become fully autonomous until Homo sapiens appeared some 170,000 years ago, or perhaps even later. The removal of manual gesture as a necessary component of language may explain the rapid advance of technology, allowing late migrations of Homo sapiens from Africa to replace all other hominids in other parts of the world, including the Neanderthals in Europe and Homo erectus in Asia. Nevertheless, the long association of vocalization with manual gesture left us a legacy of right-handedness.

  1. PROCESS DESIGN MANUAL FOR SLUDGE TREATMENT AND DISPOSAL

    EPA Science Inventory

    The purpose of this manual is to provide the engineering community and related industry with a new source of information to be used in the planning, design, and operation of present and future wastewater pollution control facilities. This manual supplements this existing knowledg...

  2. Toward brain-actuated car applications: Self-paced control with a motor imagery-based brain-computer interface.

    PubMed

    Yu, Yang; Zhou, Zongtan; Yin, Erwei; Jiang, Jun; Tang, Jingsheng; Liu, Yadong; Hu, Dewen

    2016-10-01

    This study presented a paradigm for controlling a car using an asynchronous electroencephalogram (EEG)-based brain-computer interface (BCI) and presented the experimental results of a simulation performed in an experimental environment outside the laboratory. This paradigm uses two distinct MI tasks, imaginary left- and right-hand movements, to generate a multi-task car control strategy consisting of starting the engine, moving forward, turning left, turning right, moving backward, and stopping the engine. Five healthy subjects participated in the online car control experiment, and all successfully controlled the car by following a previously outlined route. Subject S1 exhibited the most satisfactory BCI-based performance, which was comparable to the manual control-based performance. We hypothesize that the proposed self-paced car control paradigm based on EEG signals could potentially be used in car control applications, and we provide a complementary or alternative way for individuals with locked-in disorders to achieve more mobility in the future, as well as providing a supplementary car-driving strategy to assist healthy people in driving a car. Copyright © 2016 Elsevier Ltd. All rights reserved.

  3. Multi-Attribute Task Battery - Applications in pilot workload and strategic behavior research

    NASA Technical Reports Server (NTRS)

    Arnegard, Ruth J.; Comstock, J. R., Jr.

    1991-01-01

    The Multi-Attribute Task (MAT) Battery provides a benchmark set of tasks for use in a wide range of lab studies of operator performance and workload. The battery incorporates tasks analogous to activities that aircraft crewmembers perform in flight, while providing a high degree of experimenter control, performance data on each subtask, and freedom to nonpilot test subjects. Features not found in existing computer based tasks include an auditory communication task (to simulate Air Traffic Control communication), a resource management task permitting many avenues or strategies of maintaining target performance, a scheduling window which gives the operator information about future task demands, and the option of manual or automated control of tasks. Performance data are generated for each subtask. In addition, the task battery may be paused and onscreen workload rating scales presented to the subject. The MAT Battery requires a desktop computer with color graphics. The communication task requires a serial link to a second desktop computer with a voice synthesizer or digitizer card.

  4. The multi-attribute task battery for human operator workload and strategic behavior research

    NASA Technical Reports Server (NTRS)

    Comstock, J. Raymond, Jr.; Arnegard, Ruth J.

    1992-01-01

    The Multi-Attribute Task (MAT) Battery provides a benchmark set of tasks for use in a wide range of lab studies of operator performance and workload. The battery incorporates tasks analogous to activities that aircraft crewmembers perform in flight, while providing a high degree of experimenter control, performance data on each subtask, and freedom to use nonpilot test subjects. Features not found in existing computer based tasks include an auditory communication task (to simulate Air Traffic Control communication), a resource management task permitting many avenues or strategies of maintaining target performance, a scheduling window which gives the operator information about future task demands, and the option of manual or automated control of tasks. Performance data are generated for each subtask. In addition, the task battery may be paused and onscreen workload rating scales presented to the subject. The MAT Battery requires a desktop computer with color graphics. The communication task requires a serial link to a second desktop computer with a voice synthesizer or digitizer card.

  5. Pilot performance in zero-visibility precision approach. Ph.D. Thesis

    NASA Technical Reports Server (NTRS)

    Ephrath, A. R.

    1975-01-01

    The pilot's short-term decisions regarding performance assessment and failure monitoring is examined. The performance of airline pilots who flew simulated zero-visibility landing approaches is reported. Results indicate that the pilot's mode of participation in the control task has a strong effect on his workload, the induced workload being lowest when the pilot acts as a monitor during a coupled approach and highest when the pilot is an active element in the control loop. A marked increase in workload at altitudes below 500 ft. is documented at all participation modes; this increase is inversely related to distance-to-go. The participation mode is shown to have a dominant effect on failure-detection performance, with a failure in a monitored (coupled) axis being detected faster than a comparable failure in a manually-controlled axis. Touchdown performance is also documented. It is concluded that the conventional instrument panel and its associated displays are inadequate for zero-visibility operations in the final phases of the landing approach.

  6. Root-canal shaping with manual and rotary Ni-Ti files performed by students.

    PubMed

    Sonntag, D; Delschen, S; Stachniss, V

    2003-11-01

    To investigate root-canal shaping with manual and rotary Ni-Ti files performed by students. Thirty undergraduate dental students prepared 150 simulated curved root canals in resin blocks with manual Ni-Ti files with a stepback technique and 450 simulated curved canals with rotary Ni-Ti files with a crowndown technique. Incidence of fracture, preparation length, canal shape and preparation time were investigated. Questionnaires were then issued to the students for them to note their experience of the two preparation methods. Zips and elbows occurred significantly (P < 0.001) less frequently with rotary than with manual preparation. The correct preparation length was achieved significantly (P < 0.05) more often with rotary files than with manual files. Instrument fractures were recorded in only 1.3% of cases with both rotary and manual preparation. The mean time required for manual preparation was significantly (P < 0.001) longer than that required for rotary preparation. Prior experience with a hand preparation technique was not reflected in an improved quality of the subsequent rotary preparation. Approximately 83% of the students claimed to have a greater sense of security in rotary than in manual preparation. Overall 50% felt that manual and engine-driven preparation should be given equal status in undergraduate dental education. Inexperienced operators achieved better canal preparations with rotary instruments than with manual files. No difference in fracture rate was recorded between the two systems.

  7. Closed-loop double-vasopressor automated system vs manual bolus vasopressor to treat hypotension during spinal anaesthesia for caesarean section: a randomised controlled trial.

    PubMed

    Sng, B L; Tan, H S; Sia, A T H

    2014-01-01

    Hypotension necessitating vasopressor administration occurs commonly during caesarean section under spinal anaesthesia. We developed a novel vasopressor delivery system that automatically administers phenylephrine or ephedrine based on continuous non-invasive arterial pressure monitoring. A phenylephrine bolus of 50 μg was given at 30-s intervals when systolic blood pressure fell < 90% of baseline; an ephedrine bolus of 4 mg was given instead if systolic pressure fell < 90% of baseline together with a heart rate < 60 beats.min(-1). The control group used manual boluses of either phenylephrine 100 μg or ephedrine 8 mg, administered at 1-min intervals based on the same thresholds for systolic pressure and heart rate. This randomised, controlled, double-blinded trial involved 213 healthy women who underwent elective caesarean delivery under spinal anaesthesia using 11 mg hyperbaric bupivacaine with 15 μg fentanyl and 100 μg morphine. The automated vasopressor group had better systolic pressure control, with 37/106 (34.9%) having any beat-to-beat systolic pressure reading < 80% of baseline compared with 63/107 (58.9%) in the control group (p < 0.001). There was no difference in the incidence of reactive hypertension, defined as systolic pressure > 120% of baseline, with 8/106 (7.5%) in the automated vasopressor group vs 14/107 (13.1%) in the control group, or total dose of vasopressors. The automated vasopressor group had lower median absolute performance error of 8.5% vs control of 9.8% (p = 0.013), and reduced incidence of nausea (1/106 (0.9%) vs 11/107 (10.3%), p = 0.005). Neonatal umbilical cord pH, umbilical lactate and Apgar scores were similar. Hence, our system afforded better control of maternal blood pressure and reduced nausea with no increase in reactive hypertension when compared with manual boluses. © 2013 The Association of Anaesthetists of Great Britain and Ireland.

  8. 77 FR 11199 - Visual-Manual NHTSA Driver Distraction Guidelines for In-Vehicle Electronic Devices

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-02-24

    ...The National Highway Traffic Safety Administration (NHTSA) is concerned about the effects of distraction due to drivers' use of electronic devices on motor vehicle safety. Consequently, NHTSA is issuing nonbinding, voluntary NHTSA Driver Distraction Guidelines (NHTSA Guidelines) to promote safety by discouraging the introduction of excessively distracting devices in vehicles. This notice details the contents of the first phase of the NHTSA Driver Distraction Guidelines. These NHTSA Guidelines cover original equipment in-vehicle device secondary tasks (communications, entertainment, information gathering, and navigation tasks not required to drive are considered secondary tasks) performed by the driver through visual-manual means (meaning the driver looking at a device, manipulating a device-related control with the driver's hand, and watching for visual feedback). The proposed NHTSA Guidelines list certain secondary, non-driving related tasks that, based on NHTSA's research, are believed by the agency to interfere inherently with a driver's ability to safely control the vehicle. The Guidelines recommend that those in-vehicle devices be designed so that they cannot be used by the driver to perform such tasks while the driver is driving. For all other secondary, non-driving-related visual-manual tasks, the NHTSA Guidelines specify a test method for measuring the impact of task performance on driving safety while driving and time-based acceptance criteria for assessing whether a task interferes too much with driver attention to be suitable to perform while driving. If a task does not meet the acceptance criteria, the NHTSA Guidelines recommend that in- vehicle devices be designed so that the task cannot be performed by the driver while driving. In addition to identifying inherently distracting tasks and providing a means for measuring and evaluating the level of distraction associated with other non-driving-related tasks, the NHTSA Guidelines contain several design recommendations for in-vehicle devices in order to minimize their potential for distraction. NHTSA seeks comments on these NHTSA Guidelines and any suggestions for how to improve them so as to better enhance motor vehicle safety.

  9. Ohio manual of uniform traffic control devices [2003

    DOT National Transportation Integrated Search

    2003-01-01

    The purpose of traffic control device and warrants for their use is to help to insure highway safety by providing for the orderly and predictable movement of all traffic and to provide such guidance and warnings as are needed. This manual sets forth ...

  10. Process Design Manual for Nitrogen Control.

    ERIC Educational Resources Information Center

    Parker, Denny S.; And Others

    This manual presents theoretical and process design criteria for the implementation of nitrogen control technology in municipal wastewater treatment facilities. Design concepts are emphasized through examination of data from full-scale and pilot installations. Design data are included on biological nitrification and denitrification, breakpoint…

  11. Tree and brush control for county road right-of-way.

    DOT National Transportation Integrated Search

    2002-10-01

    This manual summarizes the roadside tree and brush control methods used by all of Iowa's 99 : counties. It is based on interviews conducted in Spring 2002 with county engineers, roadside : managers and others. The target audience of this manual is th...

  12. Termite Pest Control - Industrial. Manual 96.

    ERIC Educational Resources Information Center

    Missouri Univ., Columbia. Agricultural Experiment Station.

    This training manual provides information needed to meet the minimum EPA standards for certification as a commercial applicator of pesticides in the termite pest control category. The text discusses general pests, especially ants, and wood-destroying organisms such as termites, beetles, and fungi. (CS)

  13. Public Health Pest Control Category Manual.

    ERIC Educational Resources Information Center

    Bowman, James S.; Turmel, Jon P.

    This manual provides information needed to meet the standards for pesticide applicator certification. It presents pest control guidelines for those organisms of public health significance. Fact sheets with line drawings discuss pests such as cockroaches, bedbugs, lice, ants, beetles, bats, birds, and rodents. (CS)

  14. The effects of sequential use of oxytocin and sublingual nitroglycerin in the cases of retained placenta.

    PubMed

    Kashanian, Maryam; Hasankhani, Samira; Sheikhansari, Narges; Bahasadri, Shohreh; Homam, Homa

    2016-10-01

    To evaluate the effects of adding sublingual nitroglycerin to oxytocin, for delivery of retained placenta after vaginal delivery. The study was performed as a placebo controlled clinical trial on women who did not finish delivering placenta after 30 min of active management of the third stage of labor. In case group, 1 mg nitroglycerin and in the control group, placebo was prescribed sublingually. In total, 80 women finished the study. The number of manual removal of placenta did not show significant difference between the two groups [25 women (62.5%) in the case and 30 women (75%) in the control group, p = 0.335]. There was no significant difference between the two groups according to duration of the third stage of labor, hemoglobin index, decline in HB index >30% and maternal vital signs after treatment. There was no significant difference between the two groups according to adverse effects [eight women (20%) in the case group and four (10%) in the control group (p = 0.348)]. The sequential use of oxytocin and sublingual nitroglycerin could not lead to delivery of more placentas and did not reduce the necessity of manual removal of placenta in comparison with placebo.

  15. ANSI/ASHRAE/IES Standard 90.1-2010 Performance Rating Method Reference Manual

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Goel, Supriya; Rosenberg, Michael I.

    This document is intended to be a reference manual for the Appendix G Performance Rating Method (PRM) of ANSI/ASHRAE/IES Standard 90.1- 2010 (Standard 90.1-2010).The PRM is used for rating the energy efficiency of commercial and high-rise residential buildings with designs that exceed the requirements of Standard 90.1. The procedures and processes described in this manual are designed to provide consistency and accuracy by filling in gaps and providing additional details needed by users of the PRM. It should be noted that this document is created independently from ASHRAE and SSPC 90.1 and is not sanctioned nor approved by either ofmore » those entities . Potential users of this manual include energy modelers, software developers and implementers of “beyond code” energy programs. Energy modelers using ASHRAE Standard 90.1-2010 for beyond code programs can use this document as a reference manual for interpreting requirements of the Performance Rating method. Software developers, developing tools for automated creation of the baseline model can use this reference manual as a guideline for developing the rules for the baseline model.« less

  16. Short-term response of Holcus lanatus L. (Common Velvetgrass) to chemical and manual control at Yosemite National Park, USA

    USGS Publications Warehouse

    Jones, Laura J.; Ostoja, Steven M.; Brooks, Matthew L.; Hutten, Martin

    2015-01-01

    One of the highest priority invasive species at both Yosemite and Sequoia and Kings Canyon national parks is Holcus lanatus L. (common velvetgrass), a perennial bunchgrass that invades mid-elevation montane meadows. Despite velvetgrass being a high priority species, there is little information available on control techniques. The goal of this project was to evaluate the short-term response of a single application of common chemical and manual velvetgrass control techniques. The study was conducted at three montane sites in Yosemite National Park. Glyphosate spot-spray treatments were applied at 0.5, 1.0, 1.5, and 2.0% concentrations, and compared with hand pulling to evaluate effects on cover of common velvetgrass, cover of other plant species, and community species richness. Posttreatment year 1 cover of common velvetgrass was 12.1% ± 1.6 in control plots, 6.3% ± 1.5 averaged over the four chemical treatments (all chemical treatments performed similarly), and 13.6% ± 1.7 for handpulled plots. This represents an approximately 50% reduction in common velvetgrass cover in chemically- treated plots recoded posttreatment year 1 and no statistically significant reduction in hand pulled plots compared with controls. However, there was no treatment effect in posttreatment year 2, and all herbicide application rates performed similarly. In addition, there were no significant treatment effects on nontarget species or species richness. These results suggest that for this level of infestation and habitat type, (1) one year of hand pulling is not an effective control method and (2) glyphosate provides some level of control in the short-term without impact to nontarget plant species, but the effect is temporary as a single year of glyphosate treatment is ineffective over a two-year period.

  17. Effect of virtual reality-based rehabilitation on upper-extremity function in patients with brain tumor: controlled trial.

    PubMed

    Yoon, Jisun; Chun, Min Ho; Lee, Sook Joung; Kim, Bo Ryun

    2015-06-01

    The aim of this study was to evaluate the benefit of virtual reality-based rehabilitation on upper-extremity function in patients with brain tumor. Patients with upper-extremity dysfunction were divided into age-matched and tumor type-matched two groups. The intervention group performed the virtual reality program 30 mins per session for 9 sessions and conventional occupational therapy 30 mins per session for 6 sessions for 3 wks, whereas the control group received conventional occupational therapy alone 30 mins per session for 15 sessions for 3 wks. The Box and Block test, the Manual Function test, and the Fugl-Meyer scale were used to evaluate upper-extremity function. The Korean version of the Modified Barthel Index was used to assess activities of daily living. Forty patients completed the study (20 for each group). Each group exhibited significant posttreatment improvements in the Box and Block test, Manual Function test, Fugl-Meyer scale, and Korean version of the Modified Barthel Index scores. The Box and Block test, the Fugl-Meyer scale, and the Manual Function test showed greater improvements in shoulder/elbow/forearm function in the intervention group and hand function in the control group. Virtual reality-based rehabilitation combined with conventional occupational therapy may be more effective than conventional occupational therapy, especially for proximal upper-extremity function in patients with brain tumor. Further studies considering hand function, such as use of virtual reality programs that targeting hand use, are required.

  18. Mechanical versus manual chest compressions for out-of-hospital cardiac arrest: a meta-analysis of randomized controlled trials

    PubMed Central

    Tang, Lu; Gu, Wan-Jie; Wang, Fei

    2015-01-01

    Recent evidence regarding mechanical chest compressions in out-of-hospital cardiac arrest (OHCA) is conflicting. The objective of this study was to perform a meta-analysis of randomized controlled trials (RCTs) to compare the effect of mechanical versus manual chest compressions on resuscitation outcomes in OHCA. PubMed, Embase, the Cochrane Central Register of Controlled Trials, and the ClinicalTrials.gov registry were searched. In total, five RCTs with 12,510 participants were included. Compared with manual chest compressions, mechanical chest compressions did not significantly improve survival with good neurological outcome to hospital discharge (relative risks (RR) 0.80, 95% CI 0.61–1.04, P = 0.10; I2 = 65%), return of spontaneous circulation (RR 1.02, 95% CI 0.95–1.09, P = 0.59; I2 = 0%), or long-term (≥6 months) survival (RR 0.96, 95% CI 0.79–1.16, P = 0.65; I2 = 16%). In addition, mechanical chest compressions were associated with worse survival to hospital admission (RR 0.94, 95% CI 0.89–1.00, P = 0.04; I2 = 0%) and to hospital discharge (RR 0.88, 95% CI 0.78–0.99, P = 0.03; I2 = 0%). Based on the current evidence, widespread use of mechanical devices for chest compressions in OHCA cannot be recommended. PMID:26503429

  19. Relative extrinsic stain removal effectiveness of a new battery-powered toothbrush and a flat trim manual toothbrush.

    PubMed

    Hunt, Sheri A; Bartizek, Robert D

    2004-01-01

    To evaluate the stain removal efficacy of two different toothbrush designs using a laboratory stained pellicle test with seven different dentifrices. The toothbrushes were a prototype powered toothbrush (Crest SpinBrush Pro Whitening) and an ADA reference manual toothbrush, as a control. The dentifrices used in the study were: Crest Dual Action Whitening (Cool Mint), Crest Extra Whitening with Tartar Control (Clean Mint), Crest MultiCare Whitening (Fresh Mint), Colgate Total, Colgate Total Plus Whitening, Arm & Hammer Advance White with Tartar Control and Rembrandt Plus with Active Dental Peroxide. This was a randomized, parallel group study that examined stain removal with a novel toothbrushing configuration adapted for powered and manual toothbrushes. Stain was scored before and after brushing for two consecutive, 1-minute periods using digital image analysis. The mean change in L* was statistically compared between toothbrushes with ANCOVA. Labial enamel specimens were obtained from bovine permanent incisors and these specimens were subjected to a laboratory staining process until the L* values for the samples were in the range of 35-45. Digital images for CIE L*a*b* analysis were captured using a high-resolution digital camera under standard polarized lighting conditions. Based on the L* values, the enamel specimens were divided into 14 groups of nine specimens each. Baseline L* values ranged from 40.62 to 41.38 for the 14 toothbrush/dentifrice combinations. The change in L* (post-brushing minus baseline), denoted as deltaL*, was calculated for each specimen and the resulting data were subjected to a two-way ANCOVA. Toothbrush type and dentifrice type were the two terms in the model, and baseline L* was the covariate. Pairwise tests were performed on the adjusted means in order to compare the stain removal efficacy of the two toothbrushes for each of the seven dentifrices evaluated. The powered toothbrush resulted in statistically significantly greater deltaL* values (all P < or = 0.006) than the manual toothbrush for every dentifrice tested. The deltaL* values for dentifrices used with the powered toothbrush were from 66.0-164.2% higher than for the same dentifrice used with the manual toothbrush.

  20. Motor Development: Manual of Alternative Procedures.

    ERIC Educational Resources Information Center

    McCormack, James E.

    The manual of alternative procedures for teaching handicapped children focuses on programming, planning, and implementing training in the gross motor (posture, limb control, locomotion) and fine motor (facial, digital) skills. The manual consists of the following sections: specific teaching tactics commonly used in motor training stiuations…

Top