Testing an automated method to estimate ground-water recharge from streamflow records
Rutledge, A.T.; Daniel, C.C.
1994-01-01
The computer program, RORA, allows automated analysis of streamflow hydrographs to estimate ground-water recharge. Output from the program, which is based on the recession-curve-displacement method (often referred to as the Rorabaugh method, for whom the program is named), was compared to estimates of recharge obtained from a manual analysis of 156 years of streamflow record from 15 streamflow-gaging stations in the eastern United States. Statistical tests showed that there was no significant difference between paired estimates of annual recharge by the two methods. Tests of results produced by the four workers who performed the manual method showed that results can differ significantly between workers. Twenty-two percent of the variation between manual and automated estimates could be attributed to having different workers perform the manual method. The program RORA will produce estimates of recharge equivalent to estimates produced manually, greatly increase the speed od analysis, and reduce the subjectivity inherent in manual analysis.
Ibrahim, Sarah A; Martini, Luigi
2014-08-01
Dissolution method transfer is a complicated yet common process in the pharmaceutical industry. With increased pharmaceutical product manufacturing and dissolution acceptance requirements, dissolution testing has become one of the most labor-intensive quality control testing methods. There is an increased trend for automation in dissolution testing, particularly for large pharmaceutical companies to reduce variability and increase personnel efficiency. There is no official guideline for dissolution testing method transfer from a manual, semi-automated, to automated dissolution tester. In this study, a manual multipoint dissolution testing procedure for an enteric-coated aspirin tablet was transferred effectively and reproducibly to a fully automated dissolution testing device, RoboDis II. Enteric-coated aspirin samples were used as a model formulation to assess the feasibility and accuracy of media pH change during continuous automated dissolution testing. Several RoboDis II parameters were evaluated to ensure the integrity and equivalency of dissolution method transfer from a manual dissolution tester. This current study provides a systematic outline for the transfer of the manual dissolution testing protocol to an automated dissolution tester. This study further supports that automated dissolution testers compliant with regulatory requirements and similar to manual dissolution testers facilitate method transfer. © 2014 Society for Laboratory Automation and Screening.
Battery Test Manual For 48 Volt Mild Hybrid Electric Vehicles
DOE Office of Scientific and Technical Information (OSTI.GOV)
Walker, Lee Kenneth
2017-03-01
This manual details the U.S. Advanced Battery Consortium and U.S. Department of Energy Vehicle Technologies Program goals, test methods, and analysis techniques for a 48 Volt Mild Hybrid Electric Vehicle system. The test methods are outlined stating with characterization tests, followed by life tests. The final section details standardized analysis techniques for 48 V systems that allow for the comparison of different programs that use this manual. An example test plan is included, along with guidance to filling in gap table numbers.
Nelwan, Erni J; Indrasanti, Evi; Sinto, Robert; Nurchaida, Farida; Sosrosumihardjo, Rustadi
2016-01-01
to evaluate the performance of Vitek2 compact machine (Biomerieux Inc. ver 04.02, France) in reference to manual methods for susceptibility test for Candida resistance among HIV/AIDS patients. a comparison study to evaluate Vitek2 compact machine (Biomerieux Inc. ver 04.02, France) in reference to manual methods for susceptibility test for Candida resistance among HIV/AIDS patient was done. Categorical agreement between manual disc diffusion and Vitek2 machine was calculated using predefined criteria. Time to susceptibility result for automated and manual methods were measured. there were 137 Candida isolates comprising eight Candida species with C.albicans and C. glabrata as the first (56.2%) and second (15.3%) most common species, respectively. For fluconazole drug, among the C. albicans, 2.6% was found resistant on manual disc diffusion methods and no resistant was determined by Vitek2 machine; whereas 100% C. krusei was identified as resistant on both methods. Resistant patterns for C. glabrata to fluconazole, voriconazole and amphotericin B were 52.4%, 23.8%, 23.8% vs. 9.5%, 9.5%, 4.8% respectively between manual diffusion disc methods and Vitek2 machine. Time to susceptibility result for automated methods compared to Vitex2 machine was shorter for all Candida species. there is a good categorical agreement between manual disc diffusion and Vitek2 machine, except for C. glabrata for measuring the antifungal resistant. Time to susceptibility result for automated methods is shorter for all Candida species.
Battery Test Manual For Plug-In Hybrid Electric Vehicles
DOE Office of Scientific and Technical Information (OSTI.GOV)
Jeffrey R. Belt
2010-09-01
This battery test procedure manual was prepared for the United States Department of Energy (DOE), Office of Energy Efficiency and Renewable Energy (EERE), Vehicle Technologies Program. It is based on technical targets established for energy storage development projects aimed at meeting system level DOE goals for Plug-in Hybrid Electric Vehicles (PHEV). The specific procedures defined in this manual support the performance and life characterization of advanced battery devices under development for PHEV’s. However, it does share some methods described in the previously published battery test manual for power-assist hybrid electric vehicles. Due to the complexity of some of the proceduresmore » and supporting analysis, a revision including some modifications and clarifications of these procedures is expected. As in previous battery and capacitor test manuals, this version of the manual defines testing methods for full-size battery systems, along with provisions for scaling these tests for modules, cells or other subscale level devices.« less
Battery Test Manual For Plug-In Hybrid Electric Vehicles
DOE Office of Scientific and Technical Information (OSTI.GOV)
Jeffrey R. Belt
2010-12-01
This battery test procedure manual was prepared for the United States Department of Energy (DOE), Office of Energy Efficiency and Renewable Energy (EERE), Vehicle Technologies Program. It is based on technical targets established for energy storage development projects aimed at meeting system level DOE goals for Plug-in Hybrid Electric Vehicles (PHEV). The specific procedures defined in this manual support the performance and life characterization of advanced battery devices under development for PHEV’s. However, it does share some methods described in the previously published battery test manual for power-assist hybrid electric vehicles. Due to the complexity of some of the proceduresmore » and supporting analysis, a revision including some modifications and clarifications of these procedures is expected. As in previous battery and capacitor test manuals, this version of the manual defines testing methods for full-size battery systems, along with provisions for scaling these tests for modules, cells or other subscale level devices.« less
Validity of a Manual Soft Tissue Profile Prediction Method Following Mandibular Setback Osteotomy
Kolokitha, Olga-Elpis
2007-01-01
Objectives The aim of this study was to determine the validity of a manual cephalometric method used for predicting the post-operative soft tissue profiles of patients who underwent mandibular setback surgery and compare it to a computerized cephalometric prediction method (Dentofacial Planner). Lateral cephalograms of 18 adults with mandibular prognathism taken at the end of pre-surgical orthodontics and approximately one year after surgery were used. Methods To test the validity of the manual method the prediction tracings were compared to the actual post-operative tracings. The Dentofacial Planner software was used to develop the computerized post-surgical prediction tracings. Both manual and computerized prediction printouts were analyzed by using the cephalometric system PORDIOS. Statistical analysis was performed by means of t-test. Results Comparison between manual prediction tracings and the actual post-operative profile showed that the manual method results in more convex soft tissue profiles; the upper lip was found in a more prominent position, upper lip thickness was increased and, the mandible and lower lip were found in a less posterior position than that of the actual profiles. Comparison between computerized and manual prediction methods showed that in the manual method upper lip thickness was increased, the upper lip was found in a more anterior position and the lower anterior facial height was increased as compared to the computerized prediction method. Conclusions Cephalometric simulation of post-operative soft tissue profile following orthodontic-surgical management of mandibular prognathism imposes certain limitations related to the methods implied. However, both manual and computerized prediction methods remain a useful tool for patient communication. PMID:19212468
Exponential error reduction in pretransfusion testing with automation.
South, Susan F; Casina, Tony S; Li, Lily
2012-08-01
Protecting the safety of blood transfusion is the top priority of transfusion service laboratories. Pretransfusion testing is a critical element of the entire transfusion process to enhance vein-to-vein safety. Human error associated with manual pretransfusion testing is a cause of transfusion-related mortality and morbidity and most human errors can be eliminated by automated systems. However, the uptake of automation in transfusion services has been slow and many transfusion service laboratories around the world still use manual blood group and antibody screen (G&S) methods. The goal of this study was to compare error potentials of commonly used manual (e.g., tiles and tubes) versus automated (e.g., ID-GelStation and AutoVue Innova) G&S methods. Routine G&S processes in seven transfusion service laboratories (four with manual and three with automated G&S methods) were analyzed using failure modes and effects analysis to evaluate the corresponding error potentials of each method. Manual methods contained a higher number of process steps ranging from 22 to 39, while automated G&S methods only contained six to eight steps. Corresponding to the number of the process steps that required human interactions, the risk priority number (RPN) of the manual methods ranged from 5304 to 10,976. In contrast, the RPN of the automated methods was between 129 and 436 and also demonstrated a 90% to 98% reduction of the defect opportunities in routine G&S testing. This study provided quantitative evidence on how automation could transform pretransfusion testing processes by dramatically reducing error potentials and thus would improve the safety of blood transfusion. © 2012 American Association of Blood Banks.
Validity of a manual soft tissue profile prediction method following mandibular setback osteotomy.
Kolokitha, Olga-Elpis
2007-10-01
The aim of this study was to determine the validity of a manual cephalometric method used for predicting the post-operative soft tissue profiles of patients who underwent mandibular setback surgery and compare it to a computerized cephalometric prediction method (Dentofacial Planner). Lateral cephalograms of 18 adults with mandibular prognathism taken at the end of pre-surgical orthodontics and approximately one year after surgery were used. To test the validity of the manual method the prediction tracings were compared to the actual post-operative tracings. The Dentofacial Planner software was used to develop the computerized post-surgical prediction tracings. Both manual and computerized prediction printouts were analyzed by using the cephalometric system PORDIOS. Statistical analysis was performed by means of t-test. Comparison between manual prediction tracings and the actual post-operative profile showed that the manual method results in more convex soft tissue profiles; the upper lip was found in a more prominent position, upper lip thickness was increased and, the mandible and lower lip were found in a less posterior position than that of the actual profiles. Comparison between computerized and manual prediction methods showed that in the manual method upper lip thickness was increased, the upper lip was found in a more anterior position and the lower anterior facial height was increased as compared to the computerized prediction method. Cephalometric simulation of post-operative soft tissue profile following orthodontic-surgical management of mandibular prognathism imposes certain limitations related to the methods implied. However, both manual and computerized prediction methods remain a useful tool for patient communication.
Battery Test Manual For Electric Vehicles, Revision 3
DOE Office of Scientific and Technical Information (OSTI.GOV)
Christophersen, Jon P.
2015-06-01
This battery test procedure manual was prepared for the United States Department of Energy (DOE), Office of Energy Efficiency and Renewable Energy (EERE), Vehicle Technologies Office. It is based on technical targets for commercial viability established for energy storage development projects aimed at meeting system level DOE goals for Electric Vehicles (EV). The specific procedures defined in this manual support the performance and life characterization of advanced battery devices under development for EVs. However, it does share some methods described in the previously published battery test manual for plug-in hybrid electric vehicles. Due to the complexity of some of themore » procedures and supporting analysis, future revisions including some modifications and clarifications of these procedures are expected. As in previous battery and capacitor test manuals, this version of the manual defines testing methods for full-size battery systems, along with provisions for scaling these tests for modules, cells or other subscale level devices. The DOE-United States Advanced Battery Consortium (USABC), Technical Advisory Committee (TAC) supported the development of the manual. Technical Team points of contact responsible for its development and revision are Chul Bae of Ford Motor Company and Jon P. Christophersen of the Idaho National Laboratory. The development of this manual was funded by the Unites States Department of Energy, Office of Energy Efficiency and Renewable Energy, Vehicle Technologies Office. Technical direction from DOE was provided by David Howell, Energy Storage R&D Manager and Hybrid Electric Systems Team Leader. Comments and questions regarding the manual should be directed to Jon P. Christophersen at the Idaho National Laboratory (jon.christophersen@inl.gov).« less
Performance of the BG1Luc ER TA method in a qHTS format.
Ceger, Patricia; Allen, David; Huang, Ruili; Xia, Menghang; Casey, Warren
2015-01-01
In 2012, the BG1Luc4E2 estrogen receptor (ER) transactivation (TA) method (BG1Luc ER TA) was accepted by U.S. regulatory agencies and the Organisation for Economic Co-operation and Development to detect substances with ER agonist activity. The method is now part of the Tier 1 testing battery in the Environmental Protection Agency's Endocrine Disruptor Screening Program. The BG1Luc ER TA method uses the BG1 ovarian cell line that endogenously expresses full-length ER (α and β) and is stably transfected with a plasmid containing four estrogen responsive elements upstream of a luciferase reporter gene. To allow increased throughput and testing efficiency, the BG1Luc ER TA ("BG1 manual") method was adapted for quantitative high-throughput screening (BG1 qHTS) in the U.S. Tox21 testing program. The BG1 qHTS test method was used to test approximately 10,000 chemicals three times each, and concentration-response data (n=15) were analyzed to evaluate test method performance. The balanced accuracy of the BG1 qHTS test method (97% [32/33]) was determined by comparing results to ER TA performance standards for the BG1 manual method. Concordance between the BG1 manual and qHTS methods was 92% (57/62) when calculated for a larger set of non-reference chemicals tested in both methods. These data demonstrate that the performance of the BG1 qHTS is similar to the currently accepted BG1 manual method, thereby establishing the utility of the BG1 qHTS method for identifying ER active environmental chemicals.
Battery Calendar Life Estimator Manual Modeling and Simulation
DOE Office of Scientific and Technical Information (OSTI.GOV)
Jon P. Christophersen; Ira Bloom; Ed Thomas
2012-10-01
The Battery Life Estimator (BLE) Manual has been prepared to assist developers in their efforts to estimate the calendar life of advanced batteries for automotive applications. Testing requirements and procedures are defined by the various manuals previously published under the United States Advanced Battery Consortium (USABC). The purpose of this manual is to describe and standardize a method for estimating calendar life based on statistical models and degradation data acquired from typical USABC battery testing.
Battery Life Estimator Manual Linear Modeling and Simulation
DOE Office of Scientific and Technical Information (OSTI.GOV)
Jon P. Christophersen; Ira Bloom; Ed Thomas
2009-08-01
The Battery Life Estimator (BLE) Manual has been prepared to assist developers in their efforts to estimate the calendar life of advanced batteries for automotive applications. Testing requirements and procedures are defined by the various manuals previously published under the United States Advanced Battery Consortium (USABC). The purpose of this manual is to describe and standardize a method for estimating calendar life based on statistical models and degradation data acquired from typical USABC battery testing.
Economic and workflow analysis of a blood bank automated system.
Shin, Kyung-Hwa; Kim, Hyung Hoi; Chang, Chulhun L; Lee, Eun Yup
2013-07-01
This study compared the estimated costs and times required for ABO/Rh(D) typing and unexpected antibody screening using an automated system and manual methods. The total cost included direct and labor costs. Labor costs were calculated on the basis of the average operator salaries and unit values (minutes), which was the hands-on time required to test one sample. To estimate unit values, workflows were recorded on video, and the time required for each process was analyzed separately. The unit values of ABO/Rh(D) typing using the manual method were 5.65 and 8.1 min during regular and unsocial working hours, respectively. The unit value was less than 3.5 min when several samples were tested simultaneously. The unit value for unexpected antibody screening was 2.6 min. The unit values using the automated method for ABO/Rh(D) typing, unexpected antibody screening, and both simultaneously were all 1.5 min. The total cost of ABO/Rh(D) typing of only one sample using the automated analyzer was lower than that of testing only one sample using the manual technique but higher than that of testing several samples simultaneously. The total cost of unexpected antibody screening using an automated analyzer was less than that using the manual method. ABO/Rh(D) typing using an automated analyzer incurs a lower unit value and cost than that using the manual technique when only one sample is tested at a time. Unexpected antibody screening using an automated analyzer always incurs a lower unit value and cost than that using the manual technique.
Association between heart rate variability and manual pulse rate.
Hart, John
2013-09-01
One model for neurological assessment in chiropractic pertains to autonomic variability, tested commonly with heart rate variability (HRV). Since HRV may not be convenient to use on all patient visits, more user-friendly methods may help fill-in the gaps. Accordingly, this study tests the association between manual pulse rate and heart rate variability. The manual rates were also compared to the heart rate derived from HRV. Forty-eight chiropractic students were examined with heart rate variability (SDNN and mean heart rate) and two manual radial pulse rate measurements. Inclusion criteria consisted of participants being chiropractic students. Exclusion criteria for 46 of the participants consisted of a body mass index being greater than 30, age greater than 35, and history of: a) dizziness upon standing, b) treatment of psychiatric disorders, and c) diabetes. No exclusion criteria were applied to the remaining two participants who were also convenience sample volunteers. Linear associations between the manual pulse rate methods and the two heart rate variability measures (SDNN and mean heart) were tested with Pearson's correlation and simple linear regression. Moderate strength inverse (expected) correlations were observed between both manual pulse rate methods and SDNN (r = -0.640, 95% CI -0.781, -0.435; r = -0.632, 95% CI -0.776, -0.425). Strong direct (expected) relationships were observed between the manual pulse rate methods and heart rate derived from HRV technology (r = 0.934, 95% CI 0.885, 0.962; r = 0.941, 95% CI 0.897, 0.966). Manual pulse rates may be a useful option for assessing autonomic variability. Furthermore, this study showed a strong relationship between manual pulse rates and heart rate derived from HRV technology.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Christophersen, Jon P.
2014-09-01
This battery test procedure manual was prepared for the United States Department of Energy (DOE), Office of Energy Efficiency and Renewable Energy (EERE), Vehicle Technologies Office. It is based on technical targets for commercial viability established for energy storage development projects aimed at meeting system level DOE goals for Plug-in Hybrid Electric Vehicles (PHEV). The specific procedures defined in this manual support the performance and life characterization of advanced battery devices under development for PHEV’s. However, it does share some methods described in the previously published battery test manual for power-assist hybrid electric vehicles. Due to the complexity of somemore » of the procedures and supporting analysis, future revisions including some modifications and clarifications of these procedures are expected. As in previous battery and capacitor test manuals, this version of the manual defines testing methods for full-size battery systems, along with provisions for scaling these tests for modules, cells or other subscale level devices. The DOE-United States Advanced Battery Consortium (USABC), Technical Advisory Committee (TAC) supported the development of the manual. Technical Team points of contact responsible for its development and revision are Renata M. Arsenault of Ford Motor Company and Jon P. Christophersen of the Idaho National Laboratory. The development of this manual was funded by the Unites States Department of Energy, Office of Energy Efficiency and Renewable Energy, Vehicle Technologies Office. Technical direction from DOE was provided by David Howell, Energy Storage R&D Manager and Hybrid Electric Systems Team Leader. Comments and questions regarding the manual should be directed to Jon P. Christophersen at the Idaho National Laboratory (jon.christophersen@inl.gov).« less
Training Manuals and Technical Publications.
ERIC Educational Resources Information Center
Army Test and Evaluation Command, Aberdeen Proving Ground, MD.
The objective of the Materiel Test Procedure is to describe methods for determining the need for adequacy of comprehensiveness, and clarity of training manuals and technical publications (or other pertinent types of literature) relating to the ammunition or ammunition components being tested. (Author)
Otero, Carles; Aldaba, Mikel; López, Silvia; Díaz-Doutón, Fernando; Vera-Díaz, Fuensanta A; Pujol, Jaume
2018-06-01
To study the accommodative dynamics for predictable and unpredictable stimuli using manual and automated accommodative facility tests Materials and Methods: Seventeen young healthy subjects were tested monocularly in two consecutive sessions, using five different conditions. Two conditions replicated the conventional monocular accommodative facility tests for far and near distances, performed with manually held flippers. The other three conditions were automated and conducted using an electro-optical system and open-field autorefractor. Two of the three automated conditions replicated the predictable manual accommodative facility tests. The last automated condition was a hybrid approach using a novel method whereby far and near-accommodative-facility tests were randomly integrated into a single test of four unpredictable accommodative demands. The within-subject standard deviations for far- and near-distance-accommodative reversals were (±1,±1) cycles per minute (cpm) for the manual flipper accommodative facility conditions and (±3, ±4) cpm for the automated conditions. The 95% limits of agreement between the manual and the automated conditions for far and near distances were poor: (-18, 12) and (-15, 3). During the hybrid unpredictable condition, the response time and accommodative response parameters were significantly (p < 0.05) larger for accommodation than disaccommodation responses for high accommodative demands only. The response times during the transitions 0.17/2.17 D and 0.50/4.50 D appeared to be indistinguishable between the hybrid unpredictable and the conventional predictable automated tests. The automated accommodative facility test does not agree with the manual flipper test results. Operator delays in flipping the lens may account for these differences. This novel test, using unpredictable stimuli, provides a more comprehensive examination of accommodative dynamics than conventional manual accommodative facility tests. Unexpectedly, the unpredictability of the stimulus did not to affect accommodation dynamics. Further studies are needed to evaluate the sensitivity of this novel hybrid technique on individuals with accommodative anomalies.
Johansson, Jarkko; Alakurtti, Kati; Joutsa, Juho; Tohka, Jussi; Ruotsalainen, Ulla; Rinne, Juha O
2016-10-01
The striatum is the primary target in regional C-raclopride-PET studies, and despite its small volume, it contains several functional and anatomical subregions. The outcome of the quantitative dopamine receptor study using C-raclopride-PET depends heavily on the quality of the region-of-interest (ROI) definition of these subregions. The aim of this study was to evaluate subregional analysis techniques because new approaches have emerged, but have not yet been compared directly. In this paper, we compared manual ROI delineation with several automatic methods. The automatic methods used either direct clustering of the PET image or individualization of chosen brain atlases on the basis of MRI or PET image normalization. State-of-the-art normalization methods and atlases were applied, including those provided in the FreeSurfer, Statistical Parametric Mapping8, and FSL software packages. Evaluation of the automatic methods was based on voxel-wise congruity with the manual delineations and the test-retest variability and reliability of the outcome measures using data from seven healthy male participants who were scanned twice with C-raclopride-PET on the same day. The results show that both manual and automatic methods can be used to define striatal subregions. Although most of the methods performed well with respect to the test-retest variability and reliability of binding potential, the smallest average test-retest variability and SEM were obtained using a connectivity-based atlas and PET normalization (test-retest variability=4.5%, SEM=0.17). The current state-of-the-art automatic ROI methods can be considered good alternatives for subjective and laborious manual segmentation in C-raclopride-PET studies.
Inter-arch digital model vs. manual cast measurements: Accuracy and reliability.
Kiviahde, Heikki; Bukovac, Lea; Jussila, Päivi; Pesonen, Paula; Sipilä, Kirsi; Raustia, Aune; Pirttiniemi, Pertti
2017-06-28
The purpose of this study was to evaluate the accuracy and reliability of inter-arch measurements using digital dental models and conventional dental casts. Thirty sets of dental casts with permanent dentition were examined. Manual measurements were done with a digital caliper directly on the dental casts, and digital measurements were made on 3D models by two independent examiners. Intra-class correlation coefficients (ICC), a paired sample t-test or Wilcoxon signed-rank test, and Bland-Altman plots were used to evaluate intra- and inter-examiner error and to determine the accuracy and reliability of the measurements. The ICC values were generally good for manual and excellent for digital measurements. The Bland-Altman plots of all the measurements showed good agreement between the manual and digital methods and excellent inter-examiner agreement using the digital method. Inter-arch occlusal measurements on digital models are accurate and reliable and are superior to manual measurements.
Swanson, Brian T.; Riley, Sean P.; Cote, Mark P.; Leger, Robin R.; Moss, Isaac L.; Carlos,, John
2016-01-01
Background To date, no research has examined the reliability or predictive validity of manual unloading tests of the lumbar spine to identify potential responders to lumbar mechanical traction. Purpose To determine: (1) the intra and inter-rater reliability of a manual unloading test of the lumbar spine and (2) the criterion referenced predictive validity for the manual unloading test. Methods Ten volunteers with low back pain (LBP) underwent a manual unloading test to establish reliability. In a separate procedure, 30 consecutive patients with LBP (age 50·86±11·51) were assessed for pain in their most provocative standing position (visual analog scale (VAS) 49·53±25·52 mm). Patients were assessed with a manual unloading test in their most provocative position followed by a single application of intermittent mechanical traction. Post traction, pain in the provocative position was reassessed and utilized as the outcome criterion. Results The test of unloading demonstrated substantial intra and inter-rater reliability K = 1·00, P = 0·002, K = 0·737, P = 0·001, respectively. There were statistically significant within group differences for pain response following traction for patients with a positive manual unloading test (P<0·001), while patients with a negative manual unloading test did not demonstrate a statistically significant change (P>0·05). There were significant between group differences for proportion of responders to traction based on manual unloading response (P = 0·031), and manual unloading response demonstrated a moderate to strong relationship with traction response Phi = 0·443, P = 0·015. Discussion and conclusion The manual unloading test appears to be a reliable test and has a moderate to strong correlation with pain relief that exceeds minimal clinically important difference (MCID) following traction supporting the validity of this test. PMID:27559274
WIPP waste characterization program sampling and analysis guidance manual
DOE Office of Scientific and Technical Information (OSTI.GOV)
Not Available
1991-01-01
The Waste Isolation Pilot Plant (WIPP) Waste Characterization Program Sampling and Analysis Guidance Manual (Guidance Manual) provides a unified source of information on the sampling and analytical techniques that enable Department of Energy (DOE) facilities to comply with the requirements established in the current revision of the Quality Assurance Program Plan (QAPP) for the WIPP Experimental-Waste Characterization Program (the Program). This Guidance Manual includes all of the sampling and testing methodologies accepted by the WIPP Project Office (DOE/WPO) for use in implementing the Program requirements specified in the QAPP. This includes methods for characterizing representative samples of transuranic (TRU) wastesmore » at DOE generator sites with respect to the gas generation controlling variables defined in the WIPP bin-scale and alcove test plans, as well as waste container headspace gas sampling and analytical procedures to support waste characterization requirements under the WIPP test program and the Resource Conservation and Recovery Act (RCRA). The procedures in this Guidance Manual are comprehensive and detailed and are designed to provide the necessary guidance for the preparation of site specific procedures. The use of these procedures is intended to provide the necessary sensitivity, specificity, precision, and comparability of analyses and test results. The solutions to achieving specific program objectives will depend upon facility constraints, compliance with DOE Orders and DOE facilities' operating contractor requirements, and the knowledge and experience of the TRU waste handlers and analysts. With some analytical methods, such as gas chromatography/mass spectrometry, the Guidance Manual procedures may be used directly. With other methods, such as nondestructive/destructive characterization, the Guidance Manual provides guidance rather than a step-by-step procedure.« less
DOT National Transportation Integrated Search
2001-01-01
This manual is a reference guide for mix design and field testing technicians who deal with reclaimed asphalt pavement (RAP) in Superpave mixtures. It will provide detailed descriptions and examples of each step involved in designing and testing a Su...
Computer-aided target tracking in motion analysis studies
NASA Astrophysics Data System (ADS)
Burdick, Dominic C.; Marcuse, M. L.; Mislan, J. D.
1990-08-01
Motion analysis studies require the precise tracking of reference objects in sequential scenes. In a typical situation, events of interest are captured at high frame rates using special cameras, and selected objects or targets are tracked on a frame by frame basis to provide necessary data for motion reconstruction. Tracking is usually done using manual methods which are slow and prone to error. A computer based image analysis system has been developed that performs tracking automatically. The objective of this work was to eliminate the bottleneck due to manual methods in high volume tracking applications such as the analysis of crash test films for the automotive industry. The system has proven to be successful in tracking standard fiducial targets and other objects in crash test scenes. Over 95 percent of target positions which could be located using manual methods can be tracked by the system, with a significant improvement in throughput over manual methods. Future work will focus on the tracking of clusters of targets and on tracking deformable objects such as airbags.
Four-point bending as a method for quantitatively evaluating spinal arthrodesis in a rat model.
Robinson, Samuel T; Svet, Mark T; Kanim, Linda A; Metzger, Melodie F
2015-02-01
The most common method of evaluating the success (or failure) of rat spinal fusion procedures is manual palpation testing. Whereas manual palpation provides only a subjective binary answer (fused or not fused) regarding the success of a fusion surgery, mechanical testing can provide more quantitative data by assessing variations in strength among treatment groups. We here describe a mechanical testing method to quantitatively assess single-level spinal fusion in a rat model, to improve on the binary and subjective nature of manual palpation as an end point for fusion-related studies. We tested explanted lumbar segments from Sprague-Dawley rat spines after single-level posterolateral fusion procedures at L4-L5. Segments were classified as 'not fused,' 'restricted motion,' or 'fused' by using manual palpation testing. After thorough dissection and potting of the spine, 4-point bending in flexion then was applied to the L4-L5 motion segment, and stiffness was measured as the slope of the moment-displacement curve. Results demonstrated statistically significant differences in stiffness among all groups, which were consistent with preliminary grading according to manual palpation. In addition, the 4-point bending results provided quantitative information regarding the quality of the bony union formed and therefore enabled the comparison of fused specimens. Our results demonstrate that 4-point bending is a simple, reliable, and effective way to describe and compare results among rat spines after fusion surgery.
The utility of six over-the-counter (home) pregnancy tests.
Cole, Laurence A
2011-08-01
The home pregnancy market is rapidly evolving. It has moved from detection of pregnancy on the day of missed menstrual bleeding, to detection claims 4 days prior. It is moving from all manual tests to digital tests, with a monitor reading the bands and informing women they are pregnant. A thorough study is needed to investigate the validity of claims and evolving usefulness of devices. Studies were proposed to examine the sensitivity and specificity of home tests and their abilities to detect pregnancy. Methods examined the abilities of tests to detect human chorionic gonadotropin (hCG), hyperglycosylated hCG, free β-subunit, a mixture of these antigens in 40 individual early pregnancy urines. Using a mixture of hCG, hyperglycosylated hCG and free β-subunit typical for early pregnancy, the sensitivity of the First Response manual and digital tests was 5.5 mIU/mL, while the sensitivities of the EPT and ClearBlue brand manual and digital tests was 22 mIU/mL. On further evaluation, the First Response manual and digital tests both detected 97% of 120 pregnancies on the day of missed menstrual bleeding. The EPT manual and digital devices detected 54% and 67% of pregnancies, respectively, and the ClearBlue manual and digital devices detected 64% and 54% of pregnancies, respectively. First Response manual and digital claim >99% detection on the day of missed menses. The results here suggest similar sensitivity for these two tests. The EPT and ClearBlue manual and digital test make similar >99% claims, the data presented here disputes their elevated claim.
Natural Language Processing As an Alternative to Manual Reporting of Colonoscopy Quality Metrics
RAJU, GOTTUMUKKALA S.; LUM, PHILLIP J.; SLACK, REBECCA; THIRUMURTHI, SELVI; LYNCH, PATRICK M.; MILLER, ETHAN; WESTON, BRIAN R.; DAVILA, MARTA L.; BHUTANI, MANOOP S.; SHAFI, MEHNAZ A.; BRESALIER, ROBERT S.; DEKOVICH, ALEXANDER A.; LEE, JEFFREY H.; GUHA, SUSHOVAN; PANDE, MALA; BLECHACZ, BORIS; RASHID, ASIF; ROUTBORT, MARK; SHUTTLESWORTH, GLADIS; MISHRA, LOPA; STROEHLEIN, JOHN R.; ROSS, WILLIAM A.
2015-01-01
BACKGROUND & AIMS The adenoma detection rate (ADR) is a quality metric tied to interval colon cancer occurrence. However, manual extraction of data to calculate and track the ADR in clinical practice is labor-intensive. To overcome this difficulty, we developed a natural language processing (NLP) method to identify patients, who underwent their first screening colonoscopy, identify adenomas and sessile serrated adenomas (SSA). We compared the NLP generated results with that of manual data extraction to test the accuracy of NLP, and report on colonoscopy quality metrics using NLP. METHODS Identification of screening colonoscopies using NLP was compared with that using the manual method for 12,748 patients who underwent colonoscopies from July 2010 to February 2013. Also, identification of adenomas and SSAs using NLP was compared with that using the manual method with 2259 matched patient records. Colonoscopy ADRs using these methods were generated for each physician. RESULTS NLP correctly identified 91.3% of the screening examinations, whereas the manual method identified 87.8% of them. Both the manual method and NLP correctly identified examinations of patients with adenomas and SSAs in the matched records almost perfectly. Both NLP and manual method produce comparable values for ADR for each endoscopist as well as the group as a whole. CONCLUSIONS NLP can correctly identify screening colonoscopies, accurately identify adenomas and SSAs in a pathology database, and provide real-time quality metrics for colonoscopy. PMID:25910665
Yoon, Nara; Do, In-Gu; Cho, Eun Yoon
2014-09-01
Easy and accurate HER2 testing is essential when considering the prognostic and predictive significance of HER2 in breast cancer. The use of a fully automated, quantitative FISH assay would be helpful to detect HER2 amplification in breast cancer tissue specimens with reduced inter-laboratory variability. We compared the concordance of HER2 status as assessed by an automated FISH staining system to manual FISH testing. Using 60 formalin-fixed paraffin-embedded breast carcinoma specimens, we assessed HER2 immunoexpression with two antibodies (DAKO HercepTest and CB11). In addition, HER2 status was evaluated with automated FISH using the Leica FISH System for BOND and a manual FISH using the Abbott PathVysion DNA Probe Kit. All but one specimen were successfully stained using both FISH methods. When the data were divided into two groups according to HER2/CEP17 ratio, positive and negative, the results from both the automated and manual FISH techniques were identical for all 59 evaluable specimens. The HER2 and CEP17 copy numbers and HER2/CEP17 ratio showed great agreement between both FISH methods. The automated FISH technique was interpretable with signal intensity similar to those of the manual FISH technique. In contrast with manual FISH, the automated FISH technique showed well-preserved architecture due to low membrane digestion. HER2 immunohistochemistry and FISH results showed substantial significant agreement (κ = 1.0, p < 0.001). HER2 status can be reliably determined using a fully automated HER2 FISH system with high concordance to the well-established manual FISH method. Because of stable signal intensity and high staining quality, the automated FISH technique may be more appropriate than manual FISH for routine applications. © 2013 APMIS. Published by John Wiley & Sons Ltd.
Manual for Identification of Limited-English Proficiency Students with Special Needs. Report #11785.
ERIC Educational Resources Information Center
Ambert, Alba N.; And Others
This manual, intended to assist teachers in identifying students with limited-English proficiency who may have special needs, concentrates on four areas: language, observation, testing, and learning problems. The main part of the manual has eight sections dealing with the following topics: (1) observation techniques and methods; (2) modifications…
Precise Evaluation of Anthropometric 2D Software Processing of Hand in Comparison with Direct Method
Habibi, Ehsanollah; Soury, Shiva; Zadeh, Akbar Hasan
2013-01-01
Various studies carried out on different photo anthropometry, but each one had some deficiencies which during the years they have been resolved. The objective of this paper is to test the efficiency of two-dimensional image processing software in photo anthropometry of hand. In this applied research, 204 office workers and industrial workers were selected. Their hands were measured by manual with photo anthropometric methods. In this study, designing the “Hand Photo Anthropometry Set,” we tried to fix the angle and distance of the camera in all of the photos. Thus, some of the common mistakes in photo anthropometric method got controlled. The taken photos were analyzed by Digimizer software, version 4.1.1.0 and Digital Caliper (Model: Mitutoyo Corp., Tokyo, Japan) was used via manual method. t-test statistical test on data revealed that there is no significant difference between the manual and photo anthropometric results (P > 0.05) and the correlation coefficients for hand dimensions are similar in both methods illustrated in the range of 0.71-0.95. The statistical analyses showed that photo anthropometry can be replaced with manual methods. Furthermore, it can provide a great help to develop an anthropometric database for work gloves manufacturers. Since the hand anthropometry is a necessary input for tool design, this survey can be used to determine the percentiles of workers’ hands. PMID:24696802
Corbel, Michael J; Das, Rose Gaines; Lei, Dianliang; Xing, Dorothy K L; Horiuchi, Yoshinobu; Dobbelaer, Roland
2008-04-07
This report reflects the discussion and conclusions of a WHO group of experts from National Regulatory Authorities (NRAs), National Control Laboratories (NCLs), vaccine industries and other relevant institutions involved in standardization and control of diphtheria, tetanus and pertussis vaccines (DTP), held on 20-21 July 2006 and 28-30 March 2007, in Geneva Switzerland for the revision of WHO Manual for quality control of DTP vaccines. Taking into account recent developments and standardization in quality control methods and the revision of WHO recommendations for D, T, P vaccines, and a need for updating the manual has been recognized. In these two meetings the current situation of quality control methods in terms of potency, safety and identity tests for DTP vaccines and statistical analysis of data were reviewed. Based on the WHO recommendations and recent validation of testing methods, the content of current manual were reviewed and discussed. The group agreed that the principles to be observed in selecting methods included identifying those critical for assuring safety, efficacy and quality and which were consistent with WHO recommendations/requirements. Methods that were well recognized but not yet included in current Recommendations should be taken into account. These would include in vivo and/or in vitro methods for determining potency, safety testing and identity. The statistical analysis of the data should be revised and updated. It was noted that the mouse based assays for toxoid potency were still quite widely used and it was desirable to establish appropriate standards for these to enable the results to be related to the standard guinea pig assays. The working group was met again to review the first drafts and to input further suggestions or amendments to the contributions of the drafting groups. The revised manual was to be finalized and published by WHO.
1992-10-01
Manual CI APPENDIX D: Drawing Navigator Field Test D1 DISTRIBUTION Accesion For NTIS CRA&I OTIC TAB Unannouncea JustiteCdtOn By Distribution I "".i•I...methods replace manual methods, the automation will handle the data for the designer, thus reducing error and increasing throughput. However, the two...actively move data from one automation tool (CADD) to the other (the analysis program). This intervention involves a manual rekeying of data already in
Variability of the QuantiFERON®-TB gold in-tube test using automated and manual methods.
Whitworth, William C; Goodwin, Donald J; Racster, Laura; West, Kevin B; Chuke, Stella O; Daniels, Laura J; Campbell, Brandon H; Bohanon, Jamaria; Jaffar, Atheer T; Drane, Wanzer; Sjoberg, Paul A; Mazurek, Gerald H
2014-01-01
The QuantiFERON®-TB Gold In-Tube test (QFT-GIT) detects Mycobacterium tuberculosis (Mtb) infection by measuring release of interferon gamma (IFN-γ) when T-cells (in heparinized whole blood) are stimulated with specific Mtb antigens. The amount of IFN-γ is determined by enzyme-linked immunosorbent assay (ELISA). Automation of the ELISA method may reduce variability. To assess the impact of ELISA automation, we compared QFT-GIT results and variability when ELISAs were performed manually and with automation. Blood was collected into two sets of QFT-GIT tubes and processed at the same time. For each set, IFN-γ was measured in automated and manual ELISAs. Variability in interpretations and IFN-γ measurements was assessed between automated (A1 vs. A2) and manual (M1 vs. M2) ELISAs. Variability in IFN-γ measurements was also assessed on separate groups stratified by the mean of the four ELISAs. Subjects (N = 146) had two automated and two manual ELISAs completed. Overall, interpretations were discordant for 16 (11%) subjects. Excluding one subject with indeterminate results, 7 (4.8%) subjects had discordant automated interpretations and 10 (6.9%) subjects had discordant manual interpretations (p = 0.17). Quantitative variability was not uniform; within-subject variability was greater with higher IFN-γ measurements and with manual ELISAs. For subjects with mean TB Responses ±0.25 IU/mL of the 0.35 IU/mL cutoff, the within-subject standard deviation for two manual tests was 0.27 (CI95 = 0.22-0.37) IU/mL vs. 0.09 (CI95 = 0.07-0.12) IU/mL for two automated tests. QFT-GIT ELISA automation may reduce variability near the test cutoff. Methodological differences should be considered when interpreting and using IFN-γ release assays (IGRAs).
ABO Mistyping of cis-AB Blood Group by the Automated Microplate Technique.
Chun, Sejong; Ryu, Mi Ra; Cha, Seung-Yeon; Seo, Ji-Young; Cho, Duck
2018-01-01
The cis -AB phenotype, although rare, is the relatively most frequent of ABO subgroups in Koreans. To prevent ABO mistyping of cis -AB samples, our hospital has applied a combination of the manual tile method with automated devices. Herein, we report cases of ABO mistyping detected by the combination testing system. Cases that showed discrepant results by automated devices and the manual tile method were evaluated. These samples were also tested by the standard tube method. The automated devices used in this study were a QWALYS-3 and Galileo NEO. Exons 6 and 7 of the ABO gene were sequenced. 13 cases that had the cis -AB allele showed results suggestive of the cis -AB subgroup by manual methods, but were interpreted as AB by either automated device. This happened in 87.5% of these cases by QWALYS-3 and 70.0% by Galileo NEO. Genotyping results showed that 12 cases were ABO*cis-AB01/ABO*O01 or ABO*cis-AB01/ABO*O02 , and one case was ABO*cis-AB01/ ABO*A102. Cis -AB samples were mistyped as AB by the automated microplate technique in some cases. We suggest that the manual tile method can be a simple supplemental test for the detection of the cis -AB phenotype, especially in countries with relatively high cis- AB prevalence.
Sun, Jennifer K.; Qin, Haijing; Aiello, Lloyd Paul; Melia, Michele; Beck, Roy W.; Andreoli, Christopher M.; Edwards, Paul A.; Glassman, Adam R.; Pavlica, Michael R.
2012-01-01
Objective To compare visual acuity (VA) scores after autorefraction versus research protocol manual refraction in eyes of patients with diabetes and a wide range of VA. Methods Electronic Early Treatment Diabetic Retinopathy Study (E-ETDRS) VA Test© letter score (EVA) was measured after autorefraction (AR-EVA) and after Diabetic Retinopathy Clinical Research Network (DRCR.net) protocol manual refraction (MR-EVA). Testing order was randomized, study participants and VA examiners were masked to refraction source, and a second EVA utilizing an identical manual refraction (MR-EVAsupl) was performed to determine test-retest variability. Results In 878 eyes of 456 study participants, median MR-EVA was 74 (Snellen equivalent approximately 20/32). Spherical equivalent was often similar for manual and autorefraction (median difference: 0.00, 5th and 95th percentiles −1.75 to +1.13 Diopters). However, on average, MR-EVA results were slightly better than AR-EVA results across the entire VA range. Furthermore, variability between AR-EVA and MR-EVA was substantially greater than the test-retest variability of MR-EVA (P<0.001). Variability of differences was highly dependent on autorefractor model. Conclusions Across a wide range of VA at multiple sites using a variety of autorefractors, VA measurements tend to be worse with autorefraction than manual refraction. Differences between individual autorefractor models were identified. However, even among autorefractor models comparing most favorably to manual refraction, VA variability between autorefraction and manual refraction is higher than the test-retest variability of manual refraction. The results suggest that with current instruments, autorefraction is not an acceptable substitute for manual refraction for most clinical trials with primary outcomes dependent on best-corrected VA. PMID:22159173
Validating New Software for Semiautomated Liver Volumetry--Better than Manual Measurement?
Noschinski, L E; Maiwald, B; Voigt, P; Wiltberger, G; Kahn, T; Stumpp, P
2015-09-01
This prospective study compared a manual program for liver volumetry with semiautomated software. The hypothesis was that the semiautomated software would be faster, more accurate and less dependent on the evaluator's experience. Ten patients undergoing hemihepatectomy were included in this IRB approved study after written informed consent. All patients underwent a preoperative abdominal 3-phase CT scan, which was used for whole liver volumetry and volume prediction for the liver part to be resected. Two different types of software were used: 1) manual method: borders of the liver had to be defined per slice by the user; 2) semiautomated software: automatic identification of liver volume with manual assistance for definition of Couinaud segments. Measurements were done by six observers with different experience levels. Water displacement volumetry immediately after partial liver resection served as the gold standard. The resected part was examined with a CT scan after displacement volumetry. Volumetry of the resected liver scan showed excellent correlation to water displacement volumetry (manual: ρ = 0.997; semiautomated software: ρ = 0.995). The difference between the predicted volume and the real volume was significantly smaller with the semiautomated software than with the manual method (33% vs. 57%, p = 0.002). The semiautomated software was almost four times faster for volumetry of the whole liver (manual: 6:59 ± 3:04 min; semiautomated: 1:47 ± 1:11 min). Both methods for liver volumetry give an estimated liver volume close to the real one. The tested semiautomated software is faster, more accurate in predicting the volume of the resected liver part, gives more reproducible results and is less dependent on the user's experience. Both tested types of software allow exact volumetry of resected liver parts. Preoperative prediction can be performed more accurately with the semiautomated software. The semiautomated software is nearly four times faster than the tested manual program and less dependent on the user's experience. © Georg Thieme Verlag KG Stuttgart · New York.
Users manual for the Texas quick-load method for foundation load testing.
DOT National Transportation Integrated Search
1976-12-01
The Texas State Department of Highways and Public Transportation has developed and implemented a "quick-load" method for load testing piling and drilled shafts. Using this method a load test can be completed in a relatively short time of one to two...
ERIC Educational Resources Information Center
GRITTNER, FRANK; PAVLAT, RUSSELL
IN ORDER TO ASSIST NON-TECHNICAL PEOPLE IN SCHOOLS TO CONDUCT A FIELD CHECK OF LANGUAGE LABORATORY EQUIPMENT BEFORE THEY MAKE FINAL PAYMENTS, THIS MANUAL OFFERS CRITERIA, TESTS, AND METHODS OF SCORING THE QUALITY OF THE EQUIPMENT. CHECKLISTS ARE PROVIDED FOR EVALUATING CONSOLE FUNCTIONS, TAPE RECORDERS, AMPLIFIERS, SOUND QUALITY (INCLUDING…
Mbao, V; Speybroeck, N; Berkvens, D; Dolan, T; Dorny, P; Madder, M; Mulumba, M; Duchateau, L; Brandt, J; Marcotty, T
2005-07-01
Theileria parva sporozoite stabilates are used in the infection and treatment method of immunization, a widely accepted control option for East Coast fever in cattle. T. parva sporozoites are extracted from infected adult Rhipicephalus appendiculatus ticks either manually, using a pestle and a mortar, or by use of an electric homogenizer. A comparison of the two methods as a function of stabilate infectivity has never been documented. This study was designed to provide a quantitative comparison of stabilates produced by the two methods. The approach was to prepare batches of stabilate by both methods and then subject them to in vitro titration. Equivalence testing was then performed on the average effective doses (ED). The ratio of infective sporozoites yielded by the two methods was found to be 1.14 in favour of the manually ground stabilate with an upper limit of the 95% confidence interval equal to 1.3. We conclude that the choice of method rests more on costs, available infrastructure and standardization than on which method produces a richer sporozoite stabilate.
NASA Astrophysics Data System (ADS)
Fussi, Fabio; Fumagalli, Letizia; Bonomi, Tullia; Kane, Cheikh H.; Fava, Francesco; Di Mauro, Biagio; Hamidou, Barry; Niang, Magatte; Wade, Souleye; Colombo, Roberto
2016-04-01
Manual drilling refers to several drilling methods that rely on human energy to construct a borehole and complete a water supply (Danert, 2015). It can be an effective strategy to increase access to groundwater in low income countries , but manual drilling can be applied only where shallow geological layers are relatively soft and water table is not too deep. It is important therefore to identify those zones where shallow hydrogeological conditions are suitable, investigating the characteristics of shallow porous aquifers. Existing hydrogeological studies are generally focused in the characterization of deep fractures aquifers, more productive and able to ensure water supply for large settlements. Information concerning shallow porous aquifers are limited. This research has been carried out in two different study areas in West Africa (North-Western Senegal and Eastern Guinea). Aim of the research is the characterization of shallow aquifer using different methods and the identification of hydrogeological condition suitable for manual drilling implementation. Three different methods to estimate geometry and hydraulic properties of shallow unconsolidated aquifers have been used: The first method is based on the analysis of stratigraphic data obtained from borehole logs of the national water point database in both countries. The following steps have been implemented on the original information using the software TANGAFRIC, specifically designed for this study: a) identification of most frequent terms used for hydrogeological description in Senegal and Guinea database; b) definition of standard categories and manual codification of data; c) automatic extraction of average distribution of textural classes at different depth intervals in the unconsolidated aquifer; d) estimation of hydraulic parameters using conversion tables between texture and hydraulic conductivity available in the literature. . The second method is based on the interpretation of pump and recovery test in large diameter wells. K values obtained from these tests provide direct information on hydraulic parameters of shallow porous aquifers (while pump tests data obtained from deep mechanized boreholes, exploiting fractured aquifers, cannot be considered representative for the target shallow aquifer of manual drilling). The third method is based on the interpretation of stratigraphic logs and simplified pump test from manual drilled wells carried out since 2012 in Guinea. In this country a standard and systematic procedure to collect hydrogeological data from these wells (therefore indicating properties of shallow aquifer) has been put in place in 2011; it is considered one of the best example worldwide about technical data collection and systematization from manual drilling activities, but its development has been stopped because of the outbreak of Ebola in this country. The integration of these 3 methods allow to estimate geometry and hydraulic behavior of shallow unconsolidated aquifer, identifying those areas where manual drilling is feasible and estimating potential yield that can be extracted. In the mean time this research provides relevant indications concerning the use of data obtained from low cost open hand dug or manually drilled wells (rarely used in hydrogeological research) for groundwater exploration of shallow aquifers.
NASA Technical Reports Server (NTRS)
Bond, Thomas H. (Technical Monitor); Anderson, David N.
2004-01-01
This manual reviews the derivation of the similitude relationships believed to be important to ice accretion and examines ice-accretion data to evaluate their importance. Both size scaling and test-condition scaling methods employing the resulting similarity parameters are described, and experimental icing tests performed to evaluate scaling methods are reviewed with results. The material included applies primarily to unprotected, unswept geometries, but some discussion of how to approach other situations is included as well. The studies given here and scaling methods considered are applicable only to Appendix-C icing conditions. Nearly all of the experimental results presented have been obtained in sea-level tunnels. Recommendations are given regarding which scaling methods to use for both size scaling and test-condition scaling, and icing test results are described to support those recommendations. Facility limitations and size-scaling restrictions are discussed. Finally, appendices summarize the air, water and ice properties used in NASA scaling studies, give expressions for each of the similarity parameters used and provide sample calculations for the size-scaling and test-condition scaling methods advocated.
SRC-I demonstration plant analytical laboratory methods manual. Final technical report
DOE Office of Scientific and Technical Information (OSTI.GOV)
Klusaritz, M.L.; Tewari, K.C.; Tiedge, W.F.
1983-03-01
This manual is a compilation of analytical procedures required for operation of a Solvent-Refined Coal (SRC-I) demonstration or commercial plant. Each method reproduced in full includes a detailed procedure, a list of equipment and reagents, safety precautions, and, where possible, a precision statement. Procedures for the laboratory's environmental and industrial hygiene modules are not included. Required American Society for Testing and Materials (ASTM) methods are cited, and ICRC's suggested modifications to these methods for handling coal-derived products are provided.
NASA Technical Reports Server (NTRS)
Arya, Vinod K.; Halford, Gary R. (Technical Monitor)
2003-01-01
This manual presents computer programs FLAPS for characterizing and predicting fatigue and creep-fatigue resistance of metallic materials in the high-temperature, long-life regime for isothermal and nonisothermal fatigue. The programs use the Total Strain version of Strainrange Partitioning (TS-SRP), and several other life prediction methods described in this manual. The user should be thoroughly familiar with the TS-SRP and these life prediction methods before attempting to use any of these programs. Improper understanding can lead to incorrect use of the method and erroneous life predictions. An extensive database has also been developed in a parallel effort. The database is probably the largest source of high-temperature, creep-fatigue test data available in the public domain and can be used with other life-prediction methods as well. This users' manual, software, and database are all in the public domain and can be obtained by contacting the author. The Compact Disk (CD) accompanying this manual contains an executable file for the FLAPS program, two datasets required for the example problems in the manual, and the creep-fatigue data in a format compatible with these programs.
Hargrave, Catriona; Mason, Nicole; Guidi, Robyn; Miller, Julie-Anne; Becker, Jillian; Moores, Matthew; Mengersen, Kerrie; Poulsen, Michael; Harden, Fiona
2016-03-01
Time-consuming manual methods have been required to register cone-beam computed tomography (CBCT) images with plans in the Pinnacle(3) treatment planning system in order to replicate delivered treatments for adaptive radiotherapy. These methods rely on fiducial marker (FM) placement during CBCT acquisition or the image mid-point to localise the image isocentre. A quality assurance study was conducted to validate an automated CBCT-plan registration method utilising the Digital Imaging and Communications in Medicine (DICOM) Structure Set (RS) and Spatial Registration (RE) files created during online image-guided radiotherapy (IGRT). CBCTs of a phantom were acquired with FMs and predetermined setup errors using various online IGRT workflows. The CBCTs, DICOM RS and RE files were imported into Pinnacle(3) plans of the phantom and the resulting automated CBCT-plan registrations were compared to existing manual methods. A clinical protocol for the automated method was subsequently developed and tested retrospectively using CBCTs and plans for six bladder patients. The automated CBCT-plan registration method was successfully applied to thirty-four phantom CBCT images acquired with an online 0 mm action level workflow. Ten CBCTs acquired with other IGRT workflows required manual workarounds. This was addressed during the development and testing of the clinical protocol using twenty-eight patient CBCTs. The automated CBCT-plan registrations were instantaneous, replicating delivered treatments in Pinnacle(3) with errors of ±0.5 mm. These errors were comparable to mid-point-dependant manual registrations but superior to FM-dependant manual registrations. The automated CBCT-plan registration method quickly and reliably replicates delivered treatments in Pinnacle(3) for adaptive radiotherapy.
Copple, Susan S.; Jaskowski, Troy D.; Giles, Rashelle; Hill, Harry R.
2014-01-01
Objective. To evaluate NOVA View with focus on reading archived images versus microscope based manual interpretation of ANA HEp-2 slides by an experienced, certified medical technologist. Methods. 369 well defined sera from: 44 rheumatoid arthritis, 50 systemic lupus erythematosus, 35 scleroderma, 19 Sjögren's syndrome, and 10 polymyositis patients as well as 99 healthy controls were examined. In addition, 12 defined sera from the Centers for Disease Control and 100 random patient sera sent to ARUP Laboratories for ANA HEp-2 IIF testing were included. Samples were read using the archived images on NOVA View and compared to results obtained from manual reading. Results. At a 1 : 40/1 : 80 dilution the resulting comparison demonstrated 94.8%/92.9% positive, 97.4%/97.4% negative, and 96.5%/96.2% total agreements between manual IIF and NOVA View archived images. Agreement of identifiable patterns between methods was 97%, with PCNA and mixed patterns undetermined. Conclusion. Excellent agreements were obtained between reading archived images on NOVA View and manually on a fluorescent microscope. In addition, workflow benefits were observed which need to be analyzed in future studies. PMID:24741573
Automation of Military Civil Engineering and Site Design Functions: Software Evaluation
1989-09-01
promising advantage over manual methods, USACERL is to evaluate available software to determine which, if any, is best suited to the type of civil...moved. Therefore, original surface data were assembled by scaling the northing and easting distances of field elevations and entering them manually into...in the software or requesting an update or addition to the software or manuals . Responses to forms submitted during the test were received at
Reproducible segmentation of white matter hyperintensities using a new statistical definition.
Damangir, Soheil; Westman, Eric; Simmons, Andrew; Vrenken, Hugo; Wahlund, Lars-Olof; Spulber, Gabriela
2017-06-01
We present a method based on a proposed statistical definition of white matter hyperintensities (WMH), which can work with any combination of conventional magnetic resonance (MR) sequences without depending on manually delineated samples. T1-weighted, T2-weighted, FLAIR, and PD sequences acquired at 1.5 Tesla from 119 subjects from the Kings Health Partners-Dementia Case Register (healthy controls, mild cognitive impairment, Alzheimer's disease) were used. The segmentation was performed using a proposed definition for WMH based on the one-tailed Kolmogorov-Smirnov test. The presented method was verified, given all possible combinations of input sequences, against manual segmentations and a high similarity (Dice 0.85-0.91) was observed. Comparing segmentations with different input sequences to one another also yielded a high similarity (Dice 0.83-0.94) that exceeded intra-rater similarity (Dice 0.75-0.91). We compared the results with those of other available methods and showed that the segmentation based on the proposed definition has better accuracy and reproducibility in the test dataset used. Overall, the presented definition is shown to produce accurate results with higher reproducibility than manual delineation. This approach can be an alternative to other manual or automatic methods not only because of its accuracy, but also due to its good reproducibility.
Bragança, Sara; Arezes, Pedro; Carvalho, Miguel; Ashdown, Susan P; Castellucci, Ignacio; Leão, Celina
2018-01-01
Collecting anthropometric data for real-life applications demands a high degree of precision and reliability. It is important to test new equipment that will be used for data collectionOBJECTIVE:Compare two anthropometric data gathering techniques - manual methods and a Kinect-based 3D body scanner - to understand which of them gives more precise and reliable results. The data was collected using a measuring tape and a Kinect-based 3D body scanner. It was evaluated in terms of precision by considering the regular and relative Technical Error of Measurement and in terms of reliability by using the Intraclass Correlation Coefficient, Reliability Coefficient, Standard Error of Measurement and Coefficient of Variation. The results obtained showed that both methods presented better results for reliability than for precision. Both methods showed relatively good results for these two variables, however, manual methods had better results for some body measurements. Despite being considered sufficiently precise and reliable for certain applications (e.g. apparel industry), the 3D scanner tested showed, for almost every anthropometric measurement, a different result than the manual technique. Many companies design their products based on data obtained from 3D scanners, hence, understanding the precision and reliability of the equipment used is essential to obtain feasible results.
Similarity regularized sparse group lasso for cup to disc ratio computation.
Cheng, Jun; Zhang, Zhuo; Tao, Dacheng; Wong, Damon Wing Kee; Liu, Jiang; Baskaran, Mani; Aung, Tin; Wong, Tien Yin
2017-08-01
Automatic cup to disc ratio (CDR) computation from color fundus images has shown to be promising for glaucoma detection. Over the past decade, many algorithms have been proposed. In this paper, we first review the recent work in the area and then present a novel similarity-regularized sparse group lasso method for automated CDR estimation. The proposed method reconstructs the testing disc image based on a set of reference disc images by integrating the similarity between testing and the reference disc images with the sparse group lasso constraints. The reconstruction coefficients are then used to estimate the CDR of the testing image. The proposed method has been validated using 650 images with manually annotated CDRs. Experimental results show an average CDR error of 0.0616 and a correlation coefficient of 0.7, outperforming other methods. The areas under curve in the diagnostic test reach 0.843 and 0.837 when manual and automatically segmented discs are used respectively, better than other methods as well.
Activities of daily living and manual hand dexterity in persons with idiopathic parkinson disease.
Choi, Yoo-Im; Song, Chiang-Soon; Chun, Byung-Yoon
2017-03-01
[Purpose] The purpose of this study was to evaluate the relationship between daily activities and manual dexterity in persons with Parkinson disease. [Subjects and Methods] The study participants were 25 patients with idiopathic Parkinson disease. This study used two clinical tools, the box-and-block test and Schwab and England Activities of Daily Living scale, to investigate the relationship between manual dexterity and Schwab and England Activities of Daily Living score. [Results] A positive correlation was observed between the Schwab and England Activities of Daily Living and the box-and-block test scores on the more and less affected sides. Moreover, the Schwab and England Activities of Daily Living score had a greater correlation with the box-and-block test score on the less affected side than that on the more affected side. [Conclusion] Manual dexterity and activities of daily living showed a positive correlation in individuals with Parkinson disease. The results of this study suggest that manual dexterity is an important factor for predicting physical performance in daily living in persons with Parkinson disease.
Tunç, Abdulkadir; Güngen, Belma Doğan
2017-01-01
Electro-diagnostic studies are the most reliable methods in diagnosis of carpal tunnel syndrome (CTS). Although there are many risk factors associated with CTS, there are a limited number of studies in the literature indicating that manual milking, which is frequently seen in Turkey, is a risk factor for CTS. The purpose of this study was to evaluate demographic findings of cases referred due to initial diagnosis of CTS as well as aetiological data especially manual milking and to investigate the sensitivity of initial diagnosis of CTS. Six hundred patients, who were referred to our electromyography laboratory due to initial diagnosis of CTS, were included. Demographic findings, duration of complaints, existence of diabetes mellitus, and manual milking histories of all patients were recorded. Sensitivity of initial diagnosis was investigated based on electro-diagnostic test results. According to electro-diagnostic test results, 289 of the patients were diagnosed with CTS (48.17%). 110 (18.3%) of 600 patients had a history of manual milking. In 94 of this group (85.4%), CTS was detected. Statistically significant correlation was found between CTS and age, female gender, duration of complaints, obesity and manual milking. This study confirms that manual milking is an important risk factor for CTS in addition to female gender, age, symptom duration and obesity. The fact that sensitivity of initial diagnosis of CTS was found to be low according to electro-diagnostic test results indicates importance of detailed clinical evaluation.
Code of Federal Regulations, 2013 CFR
2013-01-01
... Test Procedure,” and Chapter 6, “Definitions and Acronyms,” of the EPA's “ENERGY STAR Testing Facility Guidance Manual: Building a Testing Facility and Performing the Solid State Test Method for ENERGY STAR... specified in Chapter 4, “Equipment Setup and Test Procedure,” of the EPA's “ENERGY STAR Testing Facility...
Code of Federal Regulations, 2012 CFR
2012-01-01
... Test Procedure,” and Chapter 6, “Definitions and Acronyms,” of the EPA's “ENERGY STAR Testing Facility Guidance Manual: Building a Testing Facility and Performing the Solid State Test Method for ENERGY STAR... specified in Chapter 4, “Equipment Setup and Test Procedure,” of the EPA's “ENERGY STAR Testing Facility...
Code of Federal Regulations, 2014 CFR
2014-01-01
... Test Procedure,” and Chapter 6, “Definitions and Acronyms,” of the EPA's “ENERGY STAR Testing Facility Guidance Manual: Building a Testing Facility and Performing the Solid State Test Method for ENERGY STAR... specified in Chapter 4, “Equipment Setup and Test Procedure,” of the EPA's “ENERGY STAR Testing Facility...
Code of Federal Regulations, 2011 CFR
2011-01-01
... Test Procedure,” and Chapter 6, “Definitions and Acronyms,” of the EPA's “ENERGY STAR Testing Facility Guidance Manual: Building a Testing Facility and Performing the Solid State Test Method for ENERGY STAR... specified in Chapter 4, “Equipment Setup and Test Procedure,” of the EPA's “ENERGY STAR Testing Facility...
NASA Astrophysics Data System (ADS)
Peng, Yahui; Jiang, Yulei; Soylu, Fatma N.; Tomek, Mark; Sensakovic, William; Oto, Aytekin
2012-02-01
Quantitative analysis of multi-parametric magnetic resonance (MR) images of the prostate, including T2-weighted (T2w) and diffusion-weighted (DW) images, requires accurate image registration. We compared two registration methods between T2w and DW images. We collected pre-operative MR images of 124 prostate cancer patients (68 patients scanned with a GE scanner and 56 with Philips scanners). A landmark-based rigid registration was done based on six prostate landmarks in both T2w and DW images identified by a radiologist. Independently, a researcher manually registered the same images. A radiologist visually evaluated the registration results by using a 5-point ordinal scale of 1 (worst) to 5 (best). The Wilcoxon signed-rank test was used to determine whether the radiologist's ratings of the results of the two registration methods were significantly different. Results demonstrated that both methods were accurate: the average ratings were 4.2, 3.3, and 3.8 for GE, Philips, and all images, respectively, for the landmark-based method; and 4.6, 3.7, and 4.2, respectively, for the manual method. The manual registration results were more accurate than the landmark-based registration results (p < 0.0001 for GE, Philips, and all images). Therefore, the manual method produces more accurate registration between T2w and DW images than the landmark-based method.
Setback Test Users Manual (U.S. Army Armament Research, Development and Engineering Center’s Method)
2011-09-01
Picatinny Arsenal, New Jersey. This ARDEC setback test method collapses a planer air gap against an explosive sample in a manner to mimic what could...Research, Development and Engineering Center (ARDEC), Picatinny Arsenal, New Jersey setback test collapses a planer air gap against an explosive sample
Do Treatment Manuals Undermine Youth-Therapist Alliance in Community Clinical Practice?
ERIC Educational Resources Information Center
Langer, David A.; McLeod, Bryce D.; Weisz, John R.
2011-01-01
Objective: Some critics of treatment manuals have argued that their use may undermine the quality of the client-therapist alliance. This notion was tested in the context of youth psychotherapy delivered by therapists in community clinics. Method: Seventy-six clinically referred youths (57% female, age 8-15 years, 34% Caucasian) were randomly…
Electrostatic testing of thin plastic materials
NASA Technical Reports Server (NTRS)
Skinner, S. Ballou
1988-01-01
Ten thin plastic materials (Velostat, RCAS 1200, Llumalloy, Herculite 80, RCAS 2400, Wrightlon 7000, PVC, Aclar 22A, Mylar, and Polyethylene) were tested for electrostatic properties by four different devices: (1) The static decay meter, (2) the manual triboelectric testing device, (3) the robotic triboelectric testing device, and (4) the resistivity measurement adapter device. The static decay meter measured the electrostatic decay rates in accordance with the Federal Test Method Standard 101B, Method 4046. The manual and the robotic triboelectric devices measured the triboelectric generated peak voltages and the five-second decay voltages in accordance with the criteria for acceptance standards at Kennedy Space Center. The resistivity measurement adapter measured the surface resistivity of each material. An analysis was made to correlate the data among the four testing devices. For the material tested the pass/fail results were compared for the 4046 method and the triboelectric testing devices. For the limited number of materials tested, the relationship between decay rate and surface resistivity was investigated as well as the relationship between triboelectric peak voltage and surface resistivity.
Emerencia, Ando C; Bos, Elisabeth H; Rosmalen, Judith GM; Riese, Harriëtte; Aiello, Marco; Sytema, Sjoerd; de Jonge, Peter
2015-01-01
Background Health promotion can be tailored by combining ecological momentary assessments (EMA) with time series analysis. This combined method allows for studying the temporal order of dynamic relationships among variables, which may provide concrete indications for intervention. However, application of this method in health care practice is hampered because analyses are conducted manually and advanced statistical expertise is required. Objective This study aims to show how this limitation can be overcome by introducing automated vector autoregressive modeling (VAR) of EMA data and to evaluate its feasibility through comparisons with results of previously published manual analyses. Methods We developed a Web-based open source application, called AutoVAR, which automates time series analyses of EMA data and provides output that is intended to be interpretable by nonexperts. The statistical technique we used was VAR. AutoVAR tests and evaluates all possible VAR models within a given combinatorial search space and summarizes their results, thereby replacing the researcher’s tasks of conducting the analysis, making an informed selection of models, and choosing the best model. We compared the output of AutoVAR to the output of a previously published manual analysis (n=4). Results An illustrative example consisting of 4 analyses was provided. Compared to the manual output, the AutoVAR output presents similar model characteristics and statistical results in terms of the Akaike information criterion, the Bayesian information criterion, and the test statistic of the Granger causality test. Conclusions Results suggest that automated analysis and interpretation of times series is feasible. Compared to a manual procedure, the automated procedure is more robust and can save days of time. These findings may pave the way for using time series analysis for health promotion on a larger scale. AutoVAR was evaluated using the results of a previously conducted manual analysis. Analysis of additional datasets is needed in order to validate and refine the application for general use. PMID:26254160
Applications of "Integrated Data Viewer'' (IDV) in the classroom
NASA Astrophysics Data System (ADS)
Nogueira, R.; Cutrim, E. M.
2006-06-01
Conventionally, weather products utilized in synoptic meteorology reduce phenomena occurring in four dimensions to a 2-dimensional form. This constitutes a road-block for non-atmospheric-science majors who need to take meteorology as a non-mathematical and complementary course to their major programs. This research examines the use of Integrated Data Viewer-IDV as a teaching tool, as it allows a 4-dimensional representation of weather products. IDV was tested in the teaching of synoptic meteorology, weather analysis, and weather map interpretation to non-science students in the laboratory sessions of an introductory meteorology class at Western Michigan University. Comparison of student exam scores according to the laboratory teaching techniques, i.e., traditional lab manual and IDV was performed for short- and long-term learning. Results of the statistical analysis show that the Fall 2004 students in the IDV-based lab session retained learning. However, in the Spring 2005 the exam scores did not reflect retention in learning when compared with IDV-based and MANUAL-based lab scores (short term learning, i.e., exam taken one week after the lab exercise). Testing the long-term learning, seven weeks between the two exams in the Spring 2005, show no statistically significant difference between IDV-based group scores and MANUAL-based group scores. However, the IDV group obtained exam score average slightly higher than the MANUAL group. Statistical testing of the principal hypothesis in this study, leads to the conclusion that the IDV-based method did not prove to be a better teaching tool than the traditional paper-based method. Future studies could potentially find significant differences in the effectiveness of both manual and IDV methods if the conditions had been more controlled. That is, students in the control group should not be exposed to the weather analysis using IDV during lecture.
49 CFR 383.131 - Test manuals.
Code of Federal Regulations, 2014 CFR
2014-10-01
... knowledge and skills test examiners. To be pre-approved by FMCSA, the examiner information manual must be... 49 Transportation 5 2014-10-01 2014-10-01 false Test manuals. 383.131 Section 383.131... STANDARDS; REQUIREMENTS AND PENALTIES Tests § 383.131 Test manuals. (a) Driver information manual. (1) A...
49 CFR 383.131 - Test manuals.
Code of Federal Regulations, 2011 CFR
2011-10-01
... knowledge and skills test examiners. To be pre-approved by FMCSA, the examiner information manual must be... 49 Transportation 5 2011-10-01 2011-10-01 false Test manuals. 383.131 Section 383.131... STANDARDS; REQUIREMENTS AND PENALTIES Tests § 383.131 Test manuals. (a) Driver information manual. (1) A...
49 CFR 383.131 - Test manuals.
Code of Federal Regulations, 2013 CFR
2013-10-01
... knowledge and skills test examiners. To be pre-approved by FMCSA, the examiner information manual must be... 49 Transportation 5 2013-10-01 2013-10-01 false Test manuals. 383.131 Section 383.131... STANDARDS; REQUIREMENTS AND PENALTIES Tests § 383.131 Test manuals. (a) Driver information manual. (1) A...
Alp, Alpaslan; Us, Dürdal; Hasçelik, Gülşen
2004-01-01
Rapid quantitative molecular methods are very important for the diagnosis of human immunodeficiency virus (HIV) infections, assessment of prognosis and follow up. The purpose of this study was to compare and evaluate the performances of conventional manual extraction method and automated MagNA Pure system, for the nucleic acid isolation step which is the first and most important step in molecular diagnosis of HIV infections. Plasma samples of 35 patients in which anti-HIV antibodies were found as positive by microparticule enzyme immunoassay and confirmed by immunoblotting method, were included in the study. The nucleic acids obtained simultaneously by manual isolation kit (Cobas Amplicor, HIV-1 Monitor Test, version 1.5, Roche Diagnostics) and automated system (MagNA Pure LC Total Nucleic Acid Isolation Kit, Roche Diagnostics), were amplified and detected in Cobas Amplicor (Roche Diagnostics) instrument. Twenty three of 35 samples (65.7%) were found to be positive, and 9 (25.7%) were negative by both of the methods. The agreement between the methods were detected as 91.4%, for qualitative results. Viral RNA copies detected by manual and MagNA Pure isolation methods were found between 76.0-7.590.000 (mean: 487.143) and 113.0-20.300.0000 (mean: 2.174.097) copies/ml, respectively. When both of the overall and individual results were evaluated, the number of RNA copies obtained with automatized system, were found higher than the manual method (p<0.05). Three samples which had low numbers of nucleic acids (113, 773, 857, respectively) with MagNA Pure, yielded negative results with manual method. In conclusion, the automatized MagNA Pure system was found to be a reliable, rapid and practical method for the isolation of HIV-RNA.
Turley, James P; Johnson, Todd R; Smith, Danielle Paige; Zhang, Jaijie; Brixey, Juliana J
2006-04-01
Use of medical devices often directly contributes to medical errors. Because it is difficult or impossible to change the design of existing devices, the best opportunity for improving medical device safety is during the purchasing process. However, most hospital personnel are not familiar with the usability evaluation methods designed to identify aspects of a user interface that do not support intuitive and safe use. A review of medical device operating manuals is proposed as a more practical method of usability evaluation. Operating manuals for five volumetric infusion pumps from three manufacturers were selected for this study (January-April 2003). Each manual's safety message content was evaluated to determine whether the message indicated a device design characteristic that violated known usability principles (heuristics) or indicated a violation of an affordance of the device. "Minimize memory load," with 65 violations, was the heuristic violated most frequently across pumps. Variations between pumps, including the frequency and severity of violations for each, were noted. Results suggest that manual review can provide a proxy for heuristic evaluation of the actual medical device. This method, intended to be a component of prepurchasing evaluation, can complement more formal usability evaluation methods and be used to select a subset of devices for more extensive and formal testing.
Evaluation and costs of different haemoglobin methods for use in district hospitals in Malawi
Medina Lara, A; Mundy, C; Kandulu, J; Chisuwo, L; Bates, I
2005-01-01
Aims: To evaluate the characteristics of manual haemoglobin methods in use in Malawi and provide evidence for the Ministry of Health in Malawi to enable them to choose a suitable method for district hospitals. Methods: Criteria on accuracy, clinical usefulness, user friendliness, speed, training time, and economic costs were determined by local health professionals and used to compare six different manual haemoglobin methods. These were introduced sequentially into use in a district hospital in Malawi alongside the reference method. Results: HemoCue was the optimal method based on most of the outcome measures but was also the most expensive (US$0.75/test). DHT meter and Jenway colorimeter were the second choice because they were cheaper (US$0.20–0.35/test), but they were not as accurate or user friendly as HemoCue. Conclusions: The process for choosing appropriate laboratory methods is complex and very little guidance is available for health managers in poorer countries. This paper describes the development and testing of a practical model for gathering evidence about test efficiency that could be adapted for use in other resource poor settings. PMID:15623483
An Overview of Addiction Research Center Inventory Scales (ARCI): An Appendix and Manual of Scales.
ERIC Educational Resources Information Center
Haertzen, C.A.
The Addiction Research Center Inventory is a 550 item multipurpose test measuring the broad range of physical, emotive, cognitive, and subjective effects of drugs. This manual provides technical information concerning 38 most valid scales, a quantitative method for characterizing the similarity of a profile of scores for the subject, group, or…
Pustina, Dorian; Coslett, H. Branch; Turkeltaub, Peter E.; Tustison, Nicholas; Schwartz, Myrna F.; Avants, Brian
2015-01-01
The gold standard for identifying stroke lesions is manual tracing, a method that is known to be observer dependent and time consuming, thus impractical for big data studies. We propose LINDA (Lesion Identification with Neighborhood Data Analysis), an automated segmentation algorithm capable of learning the relationship between existing manual segmentations and a single T1-weighted MRI. A dataset of 60 left hemispheric chronic stroke patients is used to build the method and test it with k-fold and leave-one-out procedures. With respect to manual tracings, predicted lesion maps showed a mean dice overlap of 0.696±0.16, Hausdorff distance of 17.9±9.8mm, and average displacement of 2.54±1.38mm. The manual and predicted lesion volumes correlated at r=0.961. An additional dataset of 45 patients was utilized to test LINDA with independent data, achieving high accuracy rates and confirming its cross-institutional applicability. To investigate the cost of moving from manual tracings to automated segmentation, we performed comparative lesion-to-symptom mapping (LSM) on five behavioral scores. Predicted and manual lesions produced similar neuro-cognitive maps, albeit with some discussed discrepancies. Of note, region-wise LSM was more robust to the prediction error than voxel-wise LSM. Our results show that, while several limitations exist, our current results compete with or exceed the state-of-the-art, producing consistent predictions, very low failure rates, and transferable knowledge between labs. This work also establishes a new viewpoint on evaluating automated methods not only with segmentation accuracy but also with brain-behavior relationships. LINDA is made available online with trained models from over 100 patients. PMID:26756101
Analysis of subsonic wind tunnel with variation shape rectangular and octagonal on test section
NASA Astrophysics Data System (ADS)
Rhakasywi, D.; Ismail; Suwandi, A.; Fadhli, A.
2018-02-01
The need for good design in the aerodynamics field required a wind tunnel design. The wind tunnel design required in this case is capable of generating laminar flow. In this research searched for wind tunnel models with rectangular and octagonal variations with objectives to generate laminar flow in the test section. The research method used numerical approach of CFD (Computational Fluid Dynamics) and manual analysis to analyze internal flow in test section. By CFD simulation results and manual analysis to generate laminar flow in the test section is a design that has an octagonal shape without filled for optimal design.
McQuade, Kevin; Price, Robert; Liu, Nelson; Ciol, Marcia A
2012-08-30
Examination of articular joints is largely based on subjective assessment of the "end-feel" of the joint in response to manually applied forces at different joint orientations. This technical report aims to describe the development of an objective method to examine joints in general, with specific application to the shoulder, and suitable for clinical use. We adapted existing hardware and developed laptop-based software to objectively record the force/displacement behavior of the glenohumeral joint during three common manual joint examination tests with the arm in six positions. An electromagnetic tracking system recorded three-dimensional positions of sensors attached to a clinician examiner and a patient. A hand-held force transducer recorded manually applied translational forces. The force and joint displacement were time-synchronized and the joint stiffness was calculated as a quantitative representation of the joint "end-feel." A methodology and specific system checks were developed to enhance clinical testing reproducibility and precision. The device and testing protocol were tested on 31 subjects (15 with healthy shoulders, and 16 with a variety of shoulder impairments). Results describe the stiffness responses, and demonstrate the feasibility of using the device and methods in clinical settings.
Use of the smartphone for end vertebra selection in scoliosis.
Pepe, Murad; Kocadal, Onur; Iyigun, Abdullah; Gunes, Zafer; Aksahin, Ertugrul; Aktekin, Cem Nuri
2017-03-01
The aim of our study was to develop a smartphone-aided end vertebra selection method and to investigate its effectiveness in Cobb angle measurement. Twenty-nine adolescent idiopathic scoliosis patients' pre-operative posteroanterior scoliosis radiographs were used for end vertebra selection and Cobb angle measurement by standard method and smartphone-aided method. Measurements were performed by 7 examiners. The intraclass correlation coefficient was used to analyze selection and measurement reliability. Summary statistics of variance calculations were used to provide 95% prediction limits for the error in Cobb angle measurements. A paired 2-tailed t test was used to analyze end vertebra selection differences. Mean absolute Cobb angle difference was 3.6° for the manual method and 1.9° for the smartphone-aided method. Both intraobserver and interobserver reliability were found excellent in manual and smartphone set for Cobb angle measurement. Both intraobserver and interobserver reliability were found excellent in manual and smartphone set for end vertebra selection. But reliability values of manual set were lower than smartphone. Two observers selected significantly different end vertebra in their repeated selections for manual method. Smartphone-aided method for end vertebra selection and Cobb angle measurement showed excellent reliability. We can expect a reduction in measurement error rates with the widespread use of this method in clinical practice. Level III, Diagnostic study. Copyright © 2016 Turkish Association of Orthopaedics and Traumatology. Production and hosting by Elsevier B.V. All rights reserved.
Rickmann, Annekatrin; Opitz, Natalia; Szurman, Peter; Boden, Karl Thomas; Jung, Sascha; Wahl, Silke; Haus, Arno; Damm, Lara-Jil; Januschowski, Kai
2018-01-01
Descemet membrane endothelial keratoplasty (DMEK) has been improved over the last decade. The aim of this study was to compare the clinical outcome of the recently introduced liquid bubble method compared to the standard manual preparation. This retrospective study evaluated the outcome of 200 patients after DMEK surgery using two different graft preparation techniques. Ninety-six DMEK were prepared by manual dissection and 104 by the novel liquid bubble technique. The mean follow-up time was 13.7 months (SD ± 8, range 6-36 months). Best corrected mean visual acuity (BCVA) increased for all patients statistically significant from baseline 0.85 logMAR (SD ± 0.5) to 0.26 logMAR (SD ± 0.27) at the final follow-up (Wilcoxon, p = 0.001). Subgroup analyses of BCVA at the final follow-up between manual dissection and liquid bubble preparation showed no statistically significant difference (Mann-Whitney U Test, p = 0.64). The mean central corneal thickness was not statistically different (manual dissection: 539 µm, SD ± 68 µm and liquid bubble technique: 534 µm, SD ± 52 µm,) between the two groups (Mann-Whitney U Test, p = 0.64). At the final follow-up, mean endothelial cell count of donor grafts was statistically not significant different at the final follow-up with 1761 cells/mm 2 (-30.7%, SD ± 352) for manual dissection compared to liquid bubble technique with 1749 cells/mm 2 (-29.9%, SD ± 501) (Mann-Whitney U-Test, p = 0.73). The re-DMEK rate was comparable for manual dissection with 8 cases (8.3%) and 7 cases (6.7%) for liquid bubble dissection (p = 0.69, Chi-Square Test). Regarding the clinical outcome, we did not find a statistical significant difference between manual dissection and liquid bubble graft preparation. Both preparation techniques lead to an equivalent clinical outcome after DMEK surgery.
Jain, Yashika
2013-01-01
Background Plaque is intimately related to the production and progress of dental caries and inflammatory gingival and periodontal diseases. Good plaque control facilitates the return to health for patients with gingival and periodontal diseases. Daily use of a toothbrush and other oral hygiene aids is the most dependable way to achieve oral health benefits for all patients. Methods A randomized clinical trial was conducted to compare the efficacy of a powered toothbrush with a manual toothbrush in controlling plaque and gingivitis over a 6-week period. The sample consisted of 60 dental students of both sexes, with ages ranging from 18 to 28 years. The samples were stratified and randomly divided into two groups of 30 by a second examiner using the coin toss method; one group used a manual toothbrush and the other group used a powered toothbrush. Each participant’s gingival index, plaque index and oral hygiene index were assessed on the seventh, 14th, and 45th days on the basis of the assigned toothbrush. Collected data were analyzed and different subgroups were compared using Student’s t-test. Results A paired t-test revealed a highly significant reduction in the gingival, plaque, and oral hygiene index scores of the manual and powered groups at the first, second, and sixth weeks (P-value < 0.0001). An unpaired t-test revealed a significant reduction between the plaque index scores of the manual and powered groups at the second week (P-value < 0.05). Another unpaired t-test revealed a highly significant reduction between the plaque index scores of the manual and powered groups at the sixth week (P-value < 0.0001). Conclusion The subject group using the powered toothbrush demonstrated clinical and statistical improvement in overall plaque scores. Powered toothbrushes offer an individual the ability to brush the teeth in a way that is optimal in terms of removing plaque and improving gingival health, conferring good brushing technique on all who use them, irrespective of manual dexterity or training. PMID:23674927
Kim, Youngwoo; Ge, Yinghui; Tao, Cheng; Zhu, Jianbing; Chapman, Arlene B.; Torres, Vicente E.; Yu, Alan S.L.; Mrug, Michal; Bennett, William M.; Flessner, Michael F.; Landsittel, Doug P.
2016-01-01
Background and objectives Our study developed a fully automated method for segmentation and volumetric measurements of kidneys from magnetic resonance images in patients with autosomal dominant polycystic kidney disease and assessed the performance of the automated method with the reference manual segmentation method. Design, setting, participants, & measurements Study patients were selected from the Consortium for Radiologic Imaging Studies of Polycystic Kidney Disease. At the enrollment of the Consortium for Radiologic Imaging Studies of Polycystic Kidney Disease Study in 2000, patients with autosomal dominant polycystic kidney disease were between 15 and 46 years of age with relatively preserved GFRs. Our fully automated segmentation method was on the basis of a spatial prior probability map of the location of kidneys in abdominal magnetic resonance images and regional mapping with total variation regularization and propagated shape constraints that were formulated into a level set framework. T2–weighted magnetic resonance image sets of 120 kidneys were selected from 60 patients with autosomal dominant polycystic kidney disease and divided into the training and test datasets. The performance of the automated method in reference to the manual method was assessed by means of two metrics: Dice similarity coefficient and intraclass correlation coefficient of segmented kidney volume. The training and test sets were swapped for crossvalidation and reanalyzed. Results Successful segmentation of kidneys was performed with the automated method in all test patients. The segmented kidney volumes ranged from 177.2 to 2634 ml (mean, 885.4±569.7 ml). The mean Dice similarity coefficient ±SD between the automated and manual methods was 0.88±0.08. The mean correlation coefficient between the two segmentation methods for the segmented volume measurements was 0.97 (P<0.001 for each crossvalidation set). The results from the crossvalidation sets were highly comparable. Conclusions We have developed a fully automated method for segmentation of kidneys from abdominal magnetic resonance images in patients with autosomal dominant polycystic kidney disease with varying kidney volumes. The performance of the automated method was in good agreement with that of manual method. PMID:26797708
Kim, Youngwoo; Ge, Yinghui; Tao, Cheng; Zhu, Jianbing; Chapman, Arlene B; Torres, Vicente E; Yu, Alan S L; Mrug, Michal; Bennett, William M; Flessner, Michael F; Landsittel, Doug P; Bae, Kyongtae T
2016-04-07
Our study developed a fully automated method for segmentation and volumetric measurements of kidneys from magnetic resonance images in patients with autosomal dominant polycystic kidney disease and assessed the performance of the automated method with the reference manual segmentation method. Study patients were selected from the Consortium for Radiologic Imaging Studies of Polycystic Kidney Disease. At the enrollment of the Consortium for Radiologic Imaging Studies of Polycystic Kidney Disease Study in 2000, patients with autosomal dominant polycystic kidney disease were between 15 and 46 years of age with relatively preserved GFRs. Our fully automated segmentation method was on the basis of a spatial prior probability map of the location of kidneys in abdominal magnetic resonance images and regional mapping with total variation regularization and propagated shape constraints that were formulated into a level set framework. T2-weighted magnetic resonance image sets of 120 kidneys were selected from 60 patients with autosomal dominant polycystic kidney disease and divided into the training and test datasets. The performance of the automated method in reference to the manual method was assessed by means of two metrics: Dice similarity coefficient and intraclass correlation coefficient of segmented kidney volume. The training and test sets were swapped for crossvalidation and reanalyzed. Successful segmentation of kidneys was performed with the automated method in all test patients. The segmented kidney volumes ranged from 177.2 to 2634 ml (mean, 885.4±569.7 ml). The mean Dice similarity coefficient ±SD between the automated and manual methods was 0.88±0.08. The mean correlation coefficient between the two segmentation methods for the segmented volume measurements was 0.97 (P<0.001 for each crossvalidation set). The results from the crossvalidation sets were highly comparable. We have developed a fully automated method for segmentation of kidneys from abdominal magnetic resonance images in patients with autosomal dominant polycystic kidney disease with varying kidney volumes. The performance of the automated method was in good agreement with that of manual method. Copyright © 2016 by the American Society of Nephrology.
Effects of Selected Task Performance Criteria at Initiating Adaptive Task Real locations
NASA Technical Reports Server (NTRS)
Montgomery, Demaris A.
2001-01-01
In the current report various performance assessment methods used to initiate mode transfers between manual control and automation for adaptive task reallocation were tested. Participants monitored two secondary tasks for critical events while actively controlling a process in a fictional system. One of the secondary monitoring tasks could be automated whenever operators' performance was below acceptable levels. Automation of the secondary task and transfer of the secondary task back to manual control were either human- or machine-initiated. Human-initiated transfers were based on the operator's assessment of the current task demands while machine-initiated transfers were based on the operators' performance. Different performance assessment methods were tested in two separate experiments.
Comparison of the effect of three autogenous bone harvesting methods on cell viability in rabbits
Moradi Haghgoo, Janet; Arabi, Seyed Reza; Hosseinipanah, Seyyed Mohammad; Solgi, Ghasem; Rastegarfard, Neda; Farhadian, Maryam
2017-01-01
Background. This study was designed to compare the viability of autogenous bone grafts, harvested using different methods, in order to determine the best harvesting technique with respect to more viable cells. Methods. In this animal experimental study, three harvesting methods, including manual instrument (chisel), rotary device and piezosurgery, were used for harvesting bone grafts from the lateral body of the mandible on the left and right sides of 10 rabbits. In each group, 20 bone samples were collected and their viability was assessed using MTS kit. Statistical analyses, including ANOVA and post hoc Tukey tests, were used for evaluating significant differences between the groups. Results. One-way ANOVA showed significant differences between all the groups (P=0.000). Data analysis using post hoc Tukey tests indicated that manual instrument and piezosurgery had no significant differences with regard to cell viability (P=0.749) and the cell viability in both groups was higher than that with the use of a rotary instrument (P=0.000). Conclusion. Autogenous bone grafts harvested with a manual instrument and piezosurgery had more viable cells in comparison to the bone chips harvested with a rotary device. PMID:28748046
Reliability and Availability Evaluation Program Manual.
1982-11-01
research and development. The manual’s purpose was to provide a practical method for making reliability measurements, measurements directly related to... Research , Development, Test and Evaluation. RMA Reliability, Maintainability and Availability. R&R Repair and Refurbishment, Repair and Replacement, etc...length. phenomena such as mechanical wear and A number of researchers in the reliability chemical deterioration. Maintenance should field 14-pages 402
A Method for Automated Detection of Usability Problems from Client User Interface Events
Saadawi, Gilan M.; Legowski, Elizabeth; Medvedeva, Olga; Chavan, Girish; Crowley, Rebecca S.
2005-01-01
Think-aloud usability analysis provides extremely useful data but is very time-consuming and expensive to perform because of the extensive manual video analysis that is required. We describe a simple method for automated detection of usability problems from client user interface events for a developing medical intelligent tutoring system. The method incorporates (1) an agent-based method for communication that funnels all interface events and system responses to a centralized database, (2) a simple schema for representing interface events and higher order subgoals, and (3) an algorithm that reproduces the criteria used for manual coding of usability problems. A correction factor was empirically determining to account for the slower task performance of users when thinking aloud. We tested the validity of the method by simultaneously identifying usability problems using TAU and manually computing them from stored interface event data using the proposed algorithm. All usability problems that did not rely on verbal utterances were detectable with the proposed method. PMID:16779121
Zhang, Lin; Huttin, Olivier; Marie, Pierre-Yves; Felblinger, Jacques; Beaumont, Marine; Chillou, Christian DE; Girerd, Nicolas; Mandry, Damien
2016-11-01
To compare three widely used methods for myocardial infarct (MI) sizing on late gadolinium-enhanced (LGE) magnetic resonance (MR) images: manual delineation and two semiautomated techniques (full-width at half-maximum [FWHM] and n-standard deviation [SD]). 3T phase-sensitive inversion-recovery (PSIR) LGE images of 114 patients after an acute MI (2-4 days and 6 months) were analyzed by two independent observers to determine both total and core infarct sizes (TIS/CIS). Manual delineation served as the reference for determination of optimal thresholds for semiautomated methods after thresholding at multiple values. Reproducibility and accuracy were expressed as overall bias ± 95% limits of agreement. Mean infarct sizes by manual methods were 39.0%/24.4% for the acute MI group (TIS/CIS) and 29.7%/17.3% for the chronic MI group. The optimal thresholds (ie, providing the closest mean value to the manual method) were FWHM30% and 3SD for the TIS measurement and FWHM45% and 6SD for the CIS measurement (paired t-test; all P > 0.05). The best reproducibility was obtained using FWHM. For TIS measurement in the acute MI group, intra-/interobserver agreements, from Bland-Altman analysis, with FWHM30%, 3SD, and manual were -0.02 ± 7.74%/-0.74 ± 5.52%, 0.31 ± 9.78%/2.96 ± 16.62% and -2.12 ± 8.86%/0.18 ± 16.12, respectively; in the chronic MI group, the corresponding values were 0.23 ± 3.5%/-2.28 ± 15.06, -0.29 ± 10.46%/3.12 ± 13.06% and 1.68 ± 6.52%/-2.88 ± 9.62%, respectively. A similar trend for reproducibility was obtained for CIS measurement. However, semiautomated methods produced inconsistent results (variabilities of 24-46%) compared to manual delineation. The FWHM technique was the most reproducible method for infarct sizing both in acute and chronic MI. However, both FWHM and n-SD methods showed limited accuracy compared to manual delineation. J. Magn. Reson. Imaging 2016;44:1206-1217. © 2016 International Society for Magnetic Resonance in Medicine.
Using pattern enumeration to accelerate process development and ramp yield
NASA Astrophysics Data System (ADS)
Zhuang, Linda; Pang, Jenny; Xu, Jessy; Tsai, Mengfeng; Wang, Amy; Zhang, Yifan; Sweis, Jason; Lai, Ya-Chieh; Ding, Hua
2016-03-01
During a new technology node process setup phase, foundries do not initially have enough product chip designs to conduct exhaustive process development. Different operational teams use manually designed simple test keys to set up their process flows and recipes. When the very first version of the design rule manual (DRM) is ready, foundries enter the process development phase where new experiment design data is manually created based on these design rules. However, these IP/test keys contain very uniform or simple design structures. This kind of design normally does not contain critical design structures or process unfriendly design patterns that pass design rule checks but are found to be less manufacturable. It is desired to have a method to generate exhaustive test patterns allowed by design rules at development stage to verify the gap of design rule and process. This paper presents a novel method of how to generate test key patterns which contain known problematic patterns as well as any constructs which designers could possibly draw based on current design rules. The enumerated test key patterns will contain the most critical design structures which are allowed by any particular design rule. A layout profiling method is used to do design chip analysis in order to find potential weak points on new incoming products so fab can take preemptive action to avoid yield loss. It can be achieved by comparing different products and leveraging the knowledge learned from previous manufactured chips to find possible yield detractors.
2011-01-01
Background Global positioning systems (GPS) are increasingly being used in health research to determine the location of study participants. Combining GPS data with data collected via travel/activity diaries allows researchers to assess where people travel in conjunction with data about trip purpose and accompaniment. However, linking GPS and diary data is problematic and to date the only method has been to match the two datasets manually, which is time consuming and unlikely to be practical for larger data sets. This paper assesses the feasibility of a new sequence alignment method of linking GPS and travel diary data in comparison with the manual matching method. Methods GPS and travel diary data obtained from a study of children's independent mobility were linked using sequence alignment algorithms to test the proof of concept. Travel diaries were assessed for quality by counting the number of errors and inconsistencies in each participant's set of diaries. The success of the sequence alignment method was compared for higher versus lower quality travel diaries, and for accompanied versus unaccompanied trips. Time taken and percentage of trips matched were compared for the sequence alignment method and the manual method. Results The sequence alignment method matched 61.9% of all trips. Higher quality travel diaries were associated with higher match rates in both the sequence alignment and manual matching methods. The sequence alignment method performed almost as well as the manual method and was an order of magnitude faster. However, the sequence alignment method was less successful at fully matching trips and at matching unaccompanied trips. Conclusions Sequence alignment is a promising method of linking GPS and travel diary data in large population datasets, especially if limitations in the trip detection algorithm are addressed. PMID:22142322
Cheng, Yuk Wah; Wilkinson, Jenny M
2015-08-01
This paper reports on an evaluation of the introduction of a blood bank automation system (Ortho AutoVue(®) Innova) in a hospital blood bank by considering the performance and workflow as compared with manual methods. The turnaround time was found to be 45% faster than the manual method. The concordance rate was found to be 100% for both ABO/Rh(D) typing and antibody screening in both of the systems and there was no significant difference in detection sensitivity for clinically significant antibodies. The Ortho AutoVue(®) Innova automated blood banking system streamlined the routine pre-transfusion testing in hospital blood bank with high throughput, equivalent sensitivity and reliability as compared with conventional manual method. Copyright © 2015 Elsevier Ltd. All rights reserved.
Parmar, Chintan; Blezek, Daniel; Estepar, Raul San Jose; Pieper, Steve; Kim, John; Aerts, Hugo J. W. L.
2017-01-01
Purpose Accurate segmentation of lung nodules is crucial in the development of imaging biomarkers for predicting malignancy of the nodules. Manual segmentation is time consuming and affected by inter-observer variability. We evaluated the robustness and accuracy of a publically available semiautomatic segmentation algorithm that is implemented in the 3D Slicer Chest Imaging Platform (CIP) and compared it with the performance of manual segmentation. Methods CT images of 354 manually segmented nodules were downloaded from the LIDC database. Four radiologists performed the manual segmentation and assessed various nodule characteristics. The semiautomatic CIP segmentation was initialized using the centroid of the manual segmentations, thereby generating four contours for each nodule. The robustness of both segmentation methods was assessed using the region of uncertainty (δ) and Dice similarity index (DSI). The robustness of the segmentation methods was compared using the Wilcoxon-signed rank test (pWilcoxon<0.05). The Dice similarity index (DSIAgree) between the manual and CIP segmentations was computed to estimate the accuracy of the semiautomatic contours. Results The median computational time of the CIP segmentation was 10 s. The median CIP and manually segmented volumes were 477 ml and 309 ml, respectively. CIP segmentations were significantly more robust than manual segmentations (median δCIP = 14ml, median dsiCIP = 99% vs. median δmanual = 222ml, median dsimanual = 82%) with pWilcoxon~10−16. The agreement between CIP and manual segmentations had a median DSIAgree of 60%. While 13% (47/354) of the nodules did not require any manual adjustment, minor to substantial manual adjustments were needed for 87% (305/354) of the nodules. CIP segmentations were observed to perform poorly (median DSIAgree≈50%) for non-/sub-solid nodules with subtle appearances and poorly defined boundaries. Conclusion Semi-automatic CIP segmentation can potentially reduce the physician workload for 13% of nodules owing to its computational efficiency and superior stability compared to manual segmentation. Although manual adjustment is needed for many cases, CIP segmentation provides a preliminary contour for physicians as a starting point. PMID:28594880
Longo, F; Nicetto, T; Banzato, T; Savio, G; Drigo, M; Meneghello, R; Concheri, G; Isola, M
2018-02-01
The aim of this ex vivo study was to test a novel three-dimensional (3D) automated computer-aided design (CAD) method (aCAD) for the computation of femoral angles in dogs from 3D reconstructions of computed tomography (CT) images. The repeatability and reproducibility of three manual radiography, manual CT reconstructions and the aCAD method for the measurement of three femoral angles were evaluated: (1) anatomical lateral distal femoral angle (aLDFA); (2) femoral neck angle (FNA); and (3) femoral torsion angle (FTA). Femoral angles of 22 femurs obtained from 16 cadavers were measured by three blinded observers. Measurements were repeated three times by each observer for each diagnostic technique. Femoral angle measurements were analysed using a mixed effects linear model for repeated measures to determine the levels of intra-observer agreement (repeatability) and inter-observer agreement (reproducibility). Repeatability and reproducibility of measurements using the aCAD method were excellent (intra-class coefficients, ICCs≥0.98) for all three angles assessed. Manual radiography and CT exhibited excellent agreement for the aLDFA measurement (ICCs≥0.90). However, FNA repeatability and reproducibility were poor (ICCs<0.8), whereas FTA measurement showed slightly higher ICCs values, except for the radiographic reproducibility, which was poor (ICCs<0.8). The computation of the 3D aCAD method provided the highest repeatability and reproducibility among the tested methodologies. Copyright © 2017 Elsevier Ltd. All rights reserved.
Survey and Experimental Testing of Nongravimetric Mass Measurement Devices
NASA Technical Reports Server (NTRS)
Oakey, W. E.; Lorenz, R.
1977-01-01
Documentation presented describes the design, testing, and evaluation of an accelerated gravimetric balance, a low mass air bearing oscillator of the spring-mass type, and a centrifugal device for liquid mass measurement. A direct mass readout method was developed to replace the oscillation period readout method which required manual calculations to determine mass. A protoype 25 gram capacity micro mass measurement device was developed and tested.
Analysis of on-line clinical laboratory manuals and practical recommendations.
Beckwith, Bruce; Schwartz, Robert; Pantanowitz, Liron
2004-04-01
On-line clinical laboratory manuals are a valuable resource for medical professionals. To our knowledge, no recommendations currently exist for their content or design. To analyze publicly accessible on-line clinical laboratory manuals and to propose guidelines for their content. We conducted an Internet search for clinical laboratory manuals written in English with individual test listings. Four individual test listings in each manual were evaluated for 16 data elements, including sample requirements, test methodology, units of measure, reference range, and critical values. Web sites were also evaluated for supplementary information and search functions. We identified 48 on-line laboratory manuals, including 24 academic or community hospital laboratories and 24 commercial or reference laboratories. All manuals had search engines and/or test indices. No single manual contained all 16 data elements evaluated. An average of 8.9 (56%) elements were present (range, 4-14). Basic sample requirements (specimen and volume needed) were the elements most commonly present (98% of manuals). The frequency of the remaining data elements varied from 10% to 90%. On-line clinical laboratory manuals originate from both hospital and commercial laboratories. While most manuals were user-friendly and contained adequate specimen-collection information, other important elements, such as reference ranges, were frequently absent. To ensure that clinical laboratory manuals are of maximal utility, we propose the following 13 data elements be included in individual test listings: test name, synonyms, test description, test methodology, sample requirements, volume requirements, collection guidelines, transport guidelines, units of measure, reference range, critical values, test availability, and date of latest revision.
Vohra, Rais; Kelner, Michael; Clark, Richard F
2009-01-01
Crotaline Polyvalent Ovine Fab antivenom (CroFab, Savage Laboratories and Protherics Inc., Brentwood, TN, USA) preparation requires that the lyophilized powder be manually reconstituted before use. We compared automated methods for driving the product into solution with the standard manual method of reconstitution, and the effect of repeated rinsing of the product vial, on the per-vial availability of antivenom. Normal saline (NS, 10 mL) was added to 12 vials of expired CroFab. Vials were assigned in pairs to each of six mixing methods, including one pair mixed manually as recommended by the product package insert. Each vial's contents were diluted to a final volume of 75 mL of normal saline. Protein concentration was measured with a colorimetric assay. The fluid left in each vial was removed and the vial was washed with 10 mL NS. Total protein yield from each step was calculated. There was no significant change in protein yield among three of five automated mixing methods when compared to manual reconstitution. Repeat rinsing of the product vial with an additional 10 mLs of fluid added to the protein yield regardless of the mixing method used. We found slightly higher protein yields with all automated methods compared to manual mixing, but only two of five comparisons with the standard mixing method demonstrated statistical significance. However, for all methods tested, the addition of a second rinsing and recovery step increased the amount of protein recovered considerably, presumably by allowing solution of protein trapped in the foamy residues. Automated mixing methods and repeat rinsing of the product vial may allow higher protein yields in the preparation of CroFab antivenom.
Tsuboyama, Takahiro; Jost, Gregor; Pietsch, Hubertus; Tomiyama, Noriyuki
2017-09-01
The aim of this study was to compare power versus manual injection in bolus shape and image quality on contrast-enhanced magnetic resonance angiography (CE-MRA). Three types of CE-MRA (head-neck 3-dimensional [3D] MRA with a test-bolus technique, thoracic-abdominal 3D MRA with a bolus-tracking technique, and thoracic-abdominal time-resolved 4-dimensional [4D] MRA) were performed after power and manual injection of gadobutrol (0.1 mmol/kg) at 2 mL/s in 12 pigs (6 sets of power and manual injections for each type of CE-MRA). For the quantitative analysis, the signal-to-noise ratio was measured on ascending aorta, descending aorta, brachiocephalic trunk, common carotid artery, and external carotid artery on the 6 sets of head-neck 3D MRA, and on ascending aorta, descending aorta, brachiocephalic trunk, abdominal aorta, celiac trunk, and renal artery on the 6 sets of thoracic-abdominal 3D MRA. Bolus shapes were evaluated on the 6 sets each of test-bolus scans and 4D MRA. For the qualitative analysis, arterial enhancement, superimposition of nontargeted enhancement, and overall image quality were evaluated on 3D MRA. Visibility of bolus transition was assessed on 4D MRA. Intraindividual comparison between power and manual injection was made by paired t test, Wilcoxon rank sum test, and analysis of variance by ranks. Signal-to-noise ratio on 3D MRA was statistically higher with power injection than with manual injection (P < 0.001). Bolus shapes (test-bolus, 4D MRA) were represented by a characteristic standard bolus curve (sharp first-pass peak followed by a gentle recirculation peak) in all the 12 scans with power injection, but only in 1 of the 12 scans with manual injection. Standard deviations of time-to-peak enhancement were smaller in power injection than in manual injection. Qualitatively, although both injection methods achieved diagnostic quality on 3D MRA, power injection exhibited significantly higher image quality than manual injection (P = 0.001) due to significantly higher arterial enhancement (P = 0.031) and less superimposition of nontargeted enhancement (P = 0.001). Visibility of bolus transition on 4D MRA was significantly better with power injection than with manual injection (P = 0.031). Compared with manual injection, power injection provides more standardized bolus shapes and higher image quality due to higher arterial enhancement and less superimposition of nontargeted vessels.
Correlation among auto-refractor, wavefront aberration, and subjective manual refraction
NASA Astrophysics Data System (ADS)
Li, Qi; Ren, Qiushi
2005-01-01
Three optometry methods which include auto-refractor, wavefront aberrometer and subjective manual refraction were studied and compared in measuring low order aberrations of 60 people"s 117 normal eyes. Paired t-test and linear regression were used to study these three methods" relationship when measuring myopia with astigmatism. In order to make the analysis more clear, we divided the 117 normal eyes into different groups according to their subjective manual refraction and redid the statistical analysis. Correlations among three methods show significant in sphere, cylinder and axis in all groups, with sphere"s correlation coefficients largest(R>0.98, P<0.01) and cylinder"s smallest (0.90
Gagnon, Dany H; Roy, Audrey; Gabison, Sharon; Duclos, Cyril; Verrier, Molly C; Nadeau, Sylvie
2016-01-01
Objectives. To quantify the association between performance-based manual wheelchair propulsion tests (20 m propulsion test, slalom test, and 6 min propulsion test), trunk and upper extremity (U/E) strength, and seated reaching capability and to establish which ones of these variables best predict performance at these tests. Methods. 15 individuals with a spinal cord injury (SCI) performed the three wheelchair propulsion tests prior to discharge from inpatient SCI rehabilitation. Trunk and U/E strength and seated reaching capability with unilateral hand support were also measured. Bivariate correlation and multiple linear regression analyses allowed determining the best determinants and predictors, respectively. Results. The performance at the three tests was moderately or strongly correlated with anterior and lateral flexion trunk strength, anterior seated reaching distance, and the shoulder, elbow, and handgrip strength measures. Shoulder adductor strength-weakest side explained 53% of the variance on the 20-meter propulsion test-maximum velocity. Shoulder adductor strength-strongest side and forward seated reaching distance explained 71% of the variance on the slalom test. Handgrip strength explained 52% of the variance on the 6-minute propulsion test. Conclusion. Performance at the manual wheelchair propulsion tests is explained by a combination of factors that should be considered in rehabilitation.
Bauquier, Sebastien H; Lai, Alan; Jiang, Jonathan L; Sui, Yi; Cook, Mark J
2015-10-01
The aim of this prospective blinded study was to evaluate an automated algorithm for spike-and-wave discharge (SWD) detection applied to EEGs from genetic absence epilepsy rats from Strasbourg (GAERS). Five GAERS underwent four sessions of 20-min EEG recording. Each EEG was manually analyzed for SWDs longer than one second by two investigators and automatically using an algorithm developed in MATLAB®. The sensitivity, specificity, positive predictive value (PPV), and negative predictive value (NPV) were calculated for the manual (reference) versus the automatic (test) methods. The results showed that the algorithm had specificity, sensitivity, PPV and NPV >94%, comparable to published methods that are based on analyzing EEG changes in the frequency domain. This provides a good alternative as a method designed to mimic human manual marking in the time domain.
Hallas, Gary; Monis, Paul
2015-01-01
The enumeration of bacteria using plate-based counts is a core technique used by food and water microbiology testing laboratories. However, manual counting of bacterial colonies is both time and labour intensive, can vary between operators and also requires manual entry of results into laboratory information management systems, which can be a source of data entry error. An alternative is to use automated digital colony counters, but there is a lack of peer-reviewed validation data to allow incorporation into standards. We compared the performance of digital counting technology (ProtoCOL3) against manual counting using criteria defined in internationally recognized standard methods. Digital colony counting provided a robust, standardized system suitable for adoption in a commercial testing environment. The digital technology has several advantages:•Improved measurement of uncertainty by using a standard and consistent counting methodology with less operator error.•Efficiency for labour and time (reduced cost).•Elimination of manual entry of data onto LIMS.•Faster result reporting to customers.
van der Krieke, Lian; Emerencia, Ando C; Bos, Elisabeth H; Rosmalen, Judith Gm; Riese, Harriëtte; Aiello, Marco; Sytema, Sjoerd; de Jonge, Peter
2015-08-07
Health promotion can be tailored by combining ecological momentary assessments (EMA) with time series analysis. This combined method allows for studying the temporal order of dynamic relationships among variables, which may provide concrete indications for intervention. However, application of this method in health care practice is hampered because analyses are conducted manually and advanced statistical expertise is required. This study aims to show how this limitation can be overcome by introducing automated vector autoregressive modeling (VAR) of EMA data and to evaluate its feasibility through comparisons with results of previously published manual analyses. We developed a Web-based open source application, called AutoVAR, which automates time series analyses of EMA data and provides output that is intended to be interpretable by nonexperts. The statistical technique we used was VAR. AutoVAR tests and evaluates all possible VAR models within a given combinatorial search space and summarizes their results, thereby replacing the researcher's tasks of conducting the analysis, making an informed selection of models, and choosing the best model. We compared the output of AutoVAR to the output of a previously published manual analysis (n=4). An illustrative example consisting of 4 analyses was provided. Compared to the manual output, the AutoVAR output presents similar model characteristics and statistical results in terms of the Akaike information criterion, the Bayesian information criterion, and the test statistic of the Granger causality test. Results suggest that automated analysis and interpretation of times series is feasible. Compared to a manual procedure, the automated procedure is more robust and can save days of time. These findings may pave the way for using time series analysis for health promotion on a larger scale. AutoVAR was evaluated using the results of a previously conducted manual analysis. Analysis of additional datasets is needed in order to validate and refine the application for general use.
NASA Hydrogen Peroxide Propellant Hazards Technical Manual
NASA Technical Reports Server (NTRS)
Baker, David L.; Greene, Ben; Frazier, Wayne
2005-01-01
The Fire, Explosion, Compatibility and Safety Hazards of Hydrogen Peroxide NASA technical manual was developed at the NASA Johnson Space Center White Sands Test Facility. NASA Technical Memorandum TM-2004-213151 covers topics concerning high concentration hydrogen peroxide including fire and explosion hazards, material and fluid reactivity, materials selection information, personnel and environmental hazards, physical and chemical properties, analytical spectroscopy, specifications, analytical methods, and material compatibility data. A summary of hydrogen peroxide-related accidents, incidents, dose calls, mishaps and lessons learned is included. The manual draws from art extensive literature base and includes recent applicable regulatory compliance documentation. The manual may be obtained by United States government agencies from NASA Johnson Space Center and used as a reference source for hazards and safe handling of hydrogen peroxide.
Science Library of Test Items. Volume Three. Mastery Testing Programme. Introduction and Manual.
ERIC Educational Resources Information Center
New South Wales Dept. of Education, Sydney (Australia).
A set of short tests aimed at measuring student mastery of specific skills in the natural sciences are presented with a description of the mastery program's purposes, development, and methods. Mastery learning, criterion-referenced testing, and the scope of skills to be tested are defined. Each of the multiple choice tests for grades 7 through 10…
Automated identification of cone photoreceptors in adaptive optics retinal images.
Li, Kaccie Y; Roorda, Austin
2007-05-01
In making noninvasive measurements of the human cone mosaic, the task of labeling each individual cone is unavoidable. Manual labeling is a time-consuming process, setting the motivation for the development of an automated method. An automated algorithm for labeling cones in adaptive optics (AO) retinal images is implemented and tested on real data. The optical fiber properties of cones aided the design of the algorithm. Out of 2153 manually labeled cones from six different images, the automated method correctly identified 94.1% of them. The agreement between the automated and the manual labeling methods varied from 92.7% to 96.2% across the six images. Results between the two methods disagreed for 1.2% to 9.1% of the cones. Voronoi analysis of large montages of AO retinal images confirmed the general hexagonal-packing structure of retinal cones as well as the general cone density variability across portions of the retina. The consistency of our measurements demonstrates the reliability and practicality of having an automated solution to this problem.
İnce, Fatma Demet; Ellidağ, Hamit Yaşar; Koseoğlu, Mehmet; Şimşek, Neşe; Yalçın, Hülya; Zengin, Mustafa Osman
2016-08-01
Urinalysis is one of the most commonly performed tests in the clinical laboratory. However, manual microscopic sediment examination is labor-intensive, time-consuming, and lacks standardization in high-volume laboratories. In this study, the concordance of analyses between manual microscopic examination and two different automatic urine sediment analyzers has been evaluated. 209 urine samples were analyzed by the Iris iQ200 ELITE (İris Diagnostics, USA), Dirui FUS-200 (DIRUI Industrial Co., China) automatic urine sediment analyzers and by manual microscopic examination. The degree of concordance (Kappa coefficient) and the rates within the same grading were evaluated. For erythrocytes, leukocytes, epithelial cells, bacteria, crystals and yeasts, the degree of concordance between the two instruments was better than the degree of concordance between the manual microscopic method and the individual devices. There was no concordance between all methods for casts. The results from the automated analyzers for erythrocytes, leukocytes and epithelial cells were similar to the result of microscopic examination. However, in order to avoid any error or uncertainty, some images (particularly: dysmorphic cells, bacteria, yeasts, casts and crystals) have to be analyzed by manual microscopic examination by trained staff. Therefore, the software programs which are used in automatic urine sediment analysers need further development to recognize urinary shaped elements more accurately. Automated systems are important in terms of time saving and standardization.
Technical Manual: 2002 Series GED Tests
ERIC Educational Resources Information Center
Ezzelle, Carol; Setzer, J. Carl
2009-01-01
This manual was written to provide technical information regarding the 2002 Series GED (General Educational Development) Tests. Throughout this manual, documentation is provided regarding the development of the GED Tests, data collection activities, as well as reliability and validity evidence. The purpose of this manual is to provide evidence…
Neubert, Ales; Fripp, Jurgen; Engstrom, Craig; Gal, Yaniv; Crozier, Stuart; Kingsley, Michael I C
2014-11-01
Magnetic resonance (MR) examinations of morphologic characteristics of intervertebral discs (IVDs) have been used extensively for biomechanical studies and clinical investigations of the lumbar spine. Traditionally, the morphologic measurements have been performed using time- and expertise-intensive manual segmentation techniques not well suited for analyses of large-scale studies.. The purpose of this study is to introduce and validate a semiautomated method for measuring IVD height and mean sagittal area (and volume) from MR images to determine if it can replace the manual assessment and enable analyses of large MR cohorts. This study compares semiautomated and manual measurements and assesses their reliability and agreement using data from repeated MR examinations. Seven healthy asymptomatic males underwent 1.5-T MR examinations of the lumbar spine involving sagittal T2-weighted fast spin-echo images obtained at baseline, pre-exercise, and postexercise conditions. Measures of the mean height and the mean sagittal area of lumbar IVDs (L1-L2 to L4-L5) were compared for two segmentation approaches: a conventional manual method (10-15 minutes to process one IVD) and a specifically developed semiautomated method (requiring only a few mouse clicks to process each subject). Both methods showed strong test-retest reproducibility evaluated on baseline and pre-exercise examinations with strong intraclass correlations for the semiautomated and manual methods for mean IVD height (intraclass correlation coefficient [ICC]=0.99, 0.98) and mean IVD area (ICC=0.98, 0.99), respectively. A bias (average deviation) of 0.38 mm (4.1%, 95% confidence interval 0.18-0.59 mm) was observed between the manual and semiautomated methods for the IVD height, whereas there was no statistically significant difference for the mean IVD area (0.1%±3.5%). The semiautomated and manual methods both detected significant exercise-induced changes in IVD height (0.20 and 0.28 mm) and mean IVD area (5.7 and 8.3 mm(2)), respectively. The presented semiautomated method provides an alternative to time- and expertise-intensive manual procedures for analysis of larger, cross-sectional, interventional, and longitudinal MR studies for morphometric analyses of lumbar IVDs. Copyright © 2014 Elsevier Inc. All rights reserved.
A narrative review of manual muscle testing and implications for muscle testing research
Conable, Katharine M.; Rosner, Anthony L.
2011-01-01
Objective Manual muscle testing (MMT) is used for a variety of purposes in health care by medical, osteopathic, chiropractic, physical therapy, rehabilitation, and athletic training professionals. The purpose of this study is to provide a narrative review of variations in techniques, durations, and forces used in MMT putting applied kinesiology (AK) muscle testing in context and highlighting aspects of muscle testing important to report in MMT research. Method PubMed, the Collected Papers of the International College of Applied Kinesiology–USA, and related texts were searched on the subjects of MMT, maximum voluntary isometric contraction testing, and make/break testing. Force parameters (magnitude, duration, timing of application), testing variations of MMT, and normative data were collected and evaluated. Results “Break” tests aim to evaluate the muscle's ability to resist a gradually increasing pressure and may test different aspects of neuromuscular control than tests against fixed resistances. Applied kinesiologists use submaximal manual break tests and a binary grading scale to test short-term changes in muscle function in response to challenges. Many of the studies reviewed were not consistent in reporting parameters for testing. Conclusions To increase the chances for replication, studies using MMT should specify parameters of the tests used, such as exact procedures and instrumentation, duration of test, peak force, and timing of application of force. PMID:22014904
NASA Technical Reports Server (NTRS)
Kreutzberg, G. A.; Rosenberg, M. J. F.; Peters, B. T.; Reschke, M. F.
2017-01-01
Due to the deconditioned state of crewmembers in the initial hours after landing, it is safer and more practical to perform a vision test while seated in a chair versus walking on a treadmill. The purpose of this study was to validate the ability of a manually operated oscillating chair to produce the oscillatory frequency and displacement equivalent of walking on a treadmill at a 4 mph pace. A fast Fourier transform (FFT)was performed on the vertical trunk acceleration to compare the peak and spread of the distribution of oscillation frequencies for each oscillating condition. Peak oscillation frequencies achieved with the manual chair were lower and more variable than those of treadmill walking and the automatic chair. This can mostly be attributed to operator fatigue. However, DVA scores across conditions were not significantly different, indicating that the manual chair can provide adequate vertical oscillation frequency and displacement with the added advantage of being portable enough for testing outside a laboratory. Furthermore the automatic chair very closely matches the oscillation frequency of treadmill walking, making it an ideal method for testing DVA in a laboratory setting.
Morgan, Kerri A.; Tucker, Susan M.; Klaesner, Joseph W.; Engsberg, Jack R.
2017-01-01
Context/Objective Developing an evidence-based approach to teaching wheelchair skills and proper propulsion for everyday wheelchair users with a spinal cord injury (SCI) is important to their rehabilitation. The purpose of this project was to pilot test manual wheelchair training based on motor learning and repetition-based approaches for new manual wheelchair users with an SCI. Design A repeated measures within-subject design was used with participants acting as their own controls. Methods Six persons with an SCI requiring the use of a manual wheelchair participated in wheelchair training. The training included nine 90-minute sessions. The primary focus was on wheelchair propulsion biomechanics with a secondary focus on wheelchair skills. Outcome Measures During Pretest 1, Pretest 2, and Posttest, wheelchair propulsion biomechanics were measured using the Wheelchair Propulsion Test and a Video Motion Capture system. During Pretest 2 and Posttest, propulsion forces using the WheelMill System and wheelchair skills using the Wheelchair Skills Test were measured. Results Significant changes in area of the push loop, hand-to-axle relationship, and slope of push forces were found. Changes in propulsion patterns were identified post-training. No significant differences were found in peak and average push forces and wheelchair skills pre- and post-training. Conclusions This project identified trends in change related to a repetition-based motor learning approach for propelling a manual wheelchair. The changes found were related to the propulsion patterns used by participants. Despite some challenges associated with implementing interventions for new manual wheelchair users, such as recruitment, the results of this study show that repetition-based training can improve biomechanics and propulsion patterns for new manual wheelchair users. PMID:26674751
40 CFR Appendix A to Part 63 - Test Methods
Code of Federal Regulations, 2010 CFR
2010-07-01
... components by a different analyst). 3.3Surrogate Reference Materials. The analyst may use surrogate compounds... the variance of the proposed method is significantly different from that of the validated method by... variables can be determined in eight experiments rather than 128 (W.J. Youden, Statistical Manual of the...
Jiang, Hui; Hanna, Eriny; Gatto, Cheryl L.; Page, Terry L.; Bhuva, Bharat; Broadie, Kendal
2016-01-01
Background Aversive olfactory classical conditioning has been the standard method to assess Drosophila learning and memory behavior for decades, yet training and testing are conducted manually under exceedingly labor-intensive conditions. To overcome this severe limitation, a fully automated, inexpensive system has been developed, which allows accurate and efficient Pavlovian associative learning/memory analyses for high-throughput pharmacological and genetic studies. New Method The automated system employs a linear actuator coupled to an odorant T-maze with airflow-mediated transfer of animals between training and testing stages. Odorant, airflow and electrical shock delivery are automatically administered and monitored during training trials. Control software allows operator-input variables to define parameters of Drosophila learning, short-term memory and long-term memory assays. Results The approach allows accurate learning/memory determinations with operational fail-safes. Automated learning indices (immediately post-training) and memory indices (after 24 hours) are comparable to traditional manual experiments, while minimizing experimenter involvement. Comparison with Existing Methods The automated system provides vast improvements over labor-intensive manual approaches with no experimenter involvement required during either training or testing phases. It provides quality control tracking of airflow rates, odorant delivery and electrical shock treatments, and an expanded platform for high-throughput studies of combinational drug tests and genetic screens. The design uses inexpensive hardware and software for a total cost of ~$500US, making it affordable to a wide range of investigators. Conclusions This study demonstrates the design, construction and testing of a fully automated Drosophila olfactory classical association apparatus to provide low-labor, high-fidelity, quality-monitored, high-throughput and inexpensive learning and memory behavioral assays. PMID:26703418
STS-37 crewmembers test CETA hand cart during training session in JSC's WETF
NASA Technical Reports Server (NTRS)
1989-01-01
STS-37 Atlantis, Orbiter Vehicle (OV) 104, Mission Specialist (MS) Jerry L. Ross and MS Jerome Apt test crew and equipment translation aid (CETA) manual hand over hand cart during underwater session in JSC's Weightless Environment Training Facility (WETF) Bldg 29. Wearing an extravehicular mobility unit (EMU), Ross pulls the CETA manual cart along the rail while Apt holds onto the back of the cart. The test will determine how difficult it is to maneuver cargo in such a manner when it is done in space on STS-37. The goal is to find the best method for astronauts to move around the exterior of Space Station Freedom (SSF).
User manual for Blossom statistical package for R
Talbert, Marian; Cade, Brian S.
2005-01-01
Blossom is an R package with functions for making statistical comparisons with distance-function based permutation tests developed by P.W. Mielke, Jr. and colleagues at Colorado State University (Mielke and Berry, 2001) and for testing parameters estimated in linear models with permutation procedures developed by B. S. Cade and colleagues at the Fort Collins Science Center, U.S. Geological Survey. This manual is intended to provide identical documentation of the statistical methods and interpretations as the manual by Cade and Richards (2005) does for the original Fortran program, but with changes made with respect to command inputs and outputs to reflect the new implementation as a package for R (R Development Core Team, 2012). This implementation in R has allowed for numerous improvements not supported by the Cade and Richards (2005) Fortran implementation, including use of categorical predictor variables in most routines.
Chapter A7. Biological Indicators
Myers, Donna N.; Wilde, Franceska D.
2003-01-01
The National Field Manual for the Collection of Water-Quality Data (National Field Manual) provides guidelines and standard procedures for U.S. Geological Survey (USGS) personnel who collect data used to assess the quality of the Nation's surface-water and ground-water resources. This chapter of the manual includes procedures for the (1) determination of biochemical oxygen demand using a 5-day bioassay test; (2) collection, identification, and enumeration of fecal indicator bacteria; (3) collection of samples and information on two laboratory methods for fecal indicator viruses (coliphages); and (4) collection of samples for protozoan pathogens. Each chapter of the National Field Manual is published separately and revised periodically. Newly published and revised chapters are posted on the World Wide Web on the USGS page 'National Field Manual for the Collection of Water-Quality Data.' The URL for this page is http://pubs.water.usgs.gov/twri9A/ (accessed November 25, 2003).
HEp-2 cell image classification method based on very deep convolutional networks with small datasets
NASA Astrophysics Data System (ADS)
Lu, Mengchi; Gao, Long; Guo, Xifeng; Liu, Qiang; Yin, Jianping
2017-07-01
Human Epithelial-2 (HEp-2) cell images staining patterns classification have been widely used to identify autoimmune diseases by the anti-Nuclear antibodies (ANA) test in the Indirect Immunofluorescence (IIF) protocol. Because manual test is time consuming, subjective and labor intensive, image-based Computer Aided Diagnosis (CAD) systems for HEp-2 cell classification are developing. However, methods proposed recently are mostly manual features extraction with low accuracy. Besides, the scale of available benchmark datasets is small, which does not exactly suitable for using deep learning methods. This issue will influence the accuracy of cell classification directly even after data augmentation. To address these issues, this paper presents a high accuracy automatic HEp-2 cell classification method with small datasets, by utilizing very deep convolutional networks (VGGNet). Specifically, the proposed method consists of three main phases, namely image preprocessing, feature extraction and classification. Moreover, an improved VGGNet is presented to address the challenges of small-scale datasets. Experimental results over two benchmark datasets demonstrate that the proposed method achieves superior performance in terms of accuracy compared with existing methods.
The Brockport Physical Fitness Test Training Manual. [Project Target].
ERIC Educational Resources Information Center
Winnick, Joseph P.; Short, Francis X., Ed.
This training manual presents information on the Brockport Physical Fitness Test (BPFT), a criterion-referenced fitness test for children and adolescents with disabilities. The first chapter of the test training manual includes information dealing with health-related criterion-referenced testing, the interaction between physical activity and…
Bouchoucha, Mongia; Akrout, Mouna; Bellali, Hédia; Bouchoucha, Rim; Tarhouni, Fadwa; Mansour, Abderraouf Ben; Zouari, Béchir
2016-01-01
Background Estimation of food portion sizes has always been a challenge in dietary studies on free-living individuals. The aim of this work was to develop and validate a food photography manual to improve the accuracy of the estimated size of consumed food portions. Methods A manual was compiled from digital photos of foods commonly consumed by the Tunisian population. The food was cooked and weighed before taking digital photographs of three portion sizes. The manual was validated by comparing the method of 24-hour recall (using photos) to the reference method [food weighing (FW)]. In both the methods, the comparison focused on food intake amounts as well as nutritional issues. Validity was assessed by Bland–Altman limits of agreement. In total, 31 male and female volunteers aged 9–89 participated in the study. Results We focused on eight food categories and compared their estimated amounts (using the 24-hour recall method) to those actually consumed (using FW). Animal products and sweets were underestimated, whereas pasta, bread, vegetables, fruits, and dairy products were overestimated. However, the difference between the two methods is not statistically significant except for pasta (p<0.05) and dairy products (p<0.05). The coefficient of correlation between the two methods is highly significant, ranging from 0.876 for pasta to 0.989 for dairy products. Nutrient intake calculated for both methods showed insignificant differences except for fat (p<0.001) and dietary fiber (p<0.05). A highly significant correlation was observed between the two methods for all micronutrients. The test agreement highlights the lack of difference between the two methods. Conclusion The difference between the 24-hour recall method using digital photos and the weighing method is acceptable. Our findings indicate that the food photography manual can be a useful tool for quantifying food portion sizes in epidemiological dietary surveys. PMID:27585631
Bouchoucha, Mongia; Akrout, Mouna; Bellali, Hédia; Bouchoucha, Rim; Tarhouni, Fadwa; Mansour, Abderraouf Ben; Zouari, Béchir
2016-01-01
Background Estimation of food portion sizes has always been a challenge in dietary studies on free-living individuals. The aim of this work was to develop and validate a food photography manual to improve the accuracy of the estimated size of consumed food portions. Methods A manual was compiled from digital photos of foods commonly consumed by the Tunisian population. The food was cooked and weighed before taking digital photographs of three portion sizes. The manual was validated by comparing the method of 24-hour recall (using photos) to the reference method [food weighing (FW)]. In both the methods, the comparison focused on food intake amounts as well as nutritional issues. Validity was assessed by Bland-Altman limits of agreement. In total, 31 male and female volunteers aged 9-89 participated in the study. Results We focused on eight food categories and compared their estimated amounts (using the 24-hour recall method) to those actually consumed (using FW). Animal products and sweets were underestimated, whereas pasta, bread, vegetables, fruits, and dairy products were overestimated. However, the difference between the two methods is not statistically significant except for pasta (p<0.05) and dairy products (p<0.05). The coefficient of correlation between the two methods is highly significant, ranging from 0.876 for pasta to 0.989 for dairy products. Nutrient intake calculated for both methods showed insignificant differences except for fat (p<0.001) and dietary fiber (p<0.05). A highly significant correlation was observed between the two methods for all micronutrients. The test agreement highlights the lack of difference between the two methods. Conclusion The difference between the 24-hour recall method using digital photos and the weighing method is acceptable. Our findings indicate that the food photography manual can be a useful tool for quantifying food portion sizes in epidemiological dietary surveys.
Roy, Audrey; Gabison, Sharon; Verrier, Molly C.
2016-01-01
Objectives. To quantify the association between performance-based manual wheelchair propulsion tests (20 m propulsion test, slalom test, and 6 min propulsion test), trunk and upper extremity (U/E) strength, and seated reaching capability and to establish which ones of these variables best predict performance at these tests. Methods. 15 individuals with a spinal cord injury (SCI) performed the three wheelchair propulsion tests prior to discharge from inpatient SCI rehabilitation. Trunk and U/E strength and seated reaching capability with unilateral hand support were also measured. Bivariate correlation and multiple linear regression analyses allowed determining the best determinants and predictors, respectively. Results. The performance at the three tests was moderately or strongly correlated with anterior and lateral flexion trunk strength, anterior seated reaching distance, and the shoulder, elbow, and handgrip strength measures. Shoulder adductor strength-weakest side explained 53% of the variance on the 20-meter propulsion test-maximum velocity. Shoulder adductor strength-strongest side and forward seated reaching distance explained 71% of the variance on the slalom test. Handgrip strength explained 52% of the variance on the 6-minute propulsion test. Conclusion. Performance at the manual wheelchair propulsion tests is explained by a combination of factors that should be considered in rehabilitation. PMID:27635262
Handbook for Classroom Testing in Peace Corps Language Programs. Manual T0068.
ERIC Educational Resources Information Center
Anderson, Neil J.
This manual provides instructors in Peace Corps language training programs with information about two kinds of classroom testing: formative, ongoing testing and summative testing that occurs at the end of an instructional period. The first of the manual's four chapters on the purposes of language testing, discusses language testing within a…
ACT Plan: Technical Manual. 2013/2014
ERIC Educational Resources Information Center
ACT, Inc., 2013
2013-01-01
This manual contains information about the American College Test (ACT) Plan® program. The principal focus of this manual is to document the Plan program's technical adequacy in light of its intended purposes. This manual supersedes the 2011 edition. The content of this manual responds to requirements of the testing industry as established in the…
A bibliography on formal methods for system specification, design and validation
NASA Technical Reports Server (NTRS)
Meyer, J. F.; Furchtgott, D. G.; Movaghar, A.
1982-01-01
Literature on the specification, design, verification, testing, and evaluation of avionics systems was surveyed, providing 655 citations. Journal papers, conference papers, and technical reports are included. Manual and computer-based methods were employed. Keywords used in the online search are listed.
Test Technical Manual 2014 GED® Test
ERIC Educational Resources Information Center
GED Testing Service, 2014
2014-01-01
This manual was written to provide technical information regarding the General Educational Development (GED®) test as evidence that the GED® test is technically sound. Throughout this manual, documentation is provided regarding the development of the GED® test and data collection activities, as well as evidence of reliability and validity. This…
40 CFR 60.59b - Reporting and recordkeeping requirements.
Code of Federal Regulations, 2010 CFR
2010-07-01
... monitor mercury or dioxin/furan instead of conducting performance testing using EPA manual test methods, all integrated 24-hour mercury concentrations or all integrated 2-week dioxin/furan concentrations as... actions taken. (4) For affected facilities that apply activated carbon for mercury or dioxin/furan control...
21 CFR 606.65 - Supplies and reagents.
Code of Federal Regulations, 2014 CFR
2014-04-01
... solutions shall be tested on a regularly scheduled basis by methods described in the Standard Operating Procedures Manual to determine their capacity to perform as required: Reagent or solution Frequency of...
21 CFR 606.65 - Supplies and reagents.
Code of Federal Regulations, 2012 CFR
2012-04-01
... solutions shall be tested on a regularly scheduled basis by methods described in the Standard Operating Procedures Manual to determine their capacity to perform as required: Reagent or solution Frequency of...
21 CFR 606.65 - Supplies and reagents.
Code of Federal Regulations, 2013 CFR
2013-04-01
... solutions shall be tested on a regularly scheduled basis by methods described in the Standard Operating Procedures Manual to determine their capacity to perform as required: Reagent or solution Frequency of...
21 CFR 606.65 - Supplies and reagents.
Code of Federal Regulations, 2011 CFR
2011-04-01
... solutions shall be tested on a regularly scheduled basis by methods described in the Standard Operating Procedures Manual to determine their capacity to perform as required: Reagent or solution Frequency of...
Saini, V.; Riekerink, R. G. M. Olde; McClure, J. T.; Barkema, H. W.
2011-01-01
Determining the accuracy and precision of a measuring instrument is pertinent in antimicrobial susceptibility testing. This study was conducted to predict the diagnostic accuracy of the Sensititre MIC mastitis panel (Sensititre) and agar disk diffusion (ADD) method with reference to the manual broth microdilution test method for antimicrobial resistance profiling of Escherichia coli (n = 156), Staphylococcus aureus (n = 154), streptococcal (n = 116), and enterococcal (n = 31) bovine clinical mastitis isolates. The activities of ampicillin, ceftiofur, cephalothin, erythromycin, oxacillin, penicillin, the penicillin-novobiocin combination, pirlimycin, and tetracycline were tested against the isolates. Diagnostic accuracy was determined by estimating the area under the receiver operating characteristic curve; intertest essential and categorical agreements were determined as well. Sensititre and the ADD method demonstrated moderate to highly accurate (71 to 99%) and moderate to perfect (71 to 100%) predictive accuracies for 74 and 76% of the isolate-antimicrobial MIC combinations, respectively. However, the diagnostic accuracy was low for S. aureus-ceftiofur/oxacillin combinations and other streptococcus-ampicillin combinations by either testing method. Essential agreement between Sensititre automatic MIC readings and MIC readings obtained by the broth microdilution test method was 87%. Essential agreement between Sensititre automatic and manual MIC reading methods was 97%. Furthermore, the ADD test method and Sensititre MIC method exhibited 92 and 91% categorical agreement (sensitive, intermediate, resistant) of results, respectively, compared with the reference method. However, both methods demonstrated lower agreement for E. coli-ampicillin/cephalothin combinations than for Gram-positive isolates. In conclusion, the Sensititre and ADD methods had moderate to high diagnostic accuracy and very good essential and categorical agreement for most udder pathogen-antimicrobial combinations and can be readily employed in veterinary diagnostic laboratories. PMID:21270215
Cha, Dong Ik; Lee, Min Woo; Song, Kyoung Doo; Oh, Young-Taek; Jeong, Ja-Yeon; Chang, Jung-Woo; Ryu, Jiwon; Lee, Kyong Joon; Kim, Jaeil; Bang, Won-Chul; Shin, Dong Kuk; Choi, Sung Jin; Koh, Dalkwon; Seo, Bong Koo; Kim, Kyunga
2017-06-01
To compare the accuracy and required time for image fusion of real-time ultrasound (US) with pre-procedural magnetic resonance (MR) images between positioning auto-registration and manual registration for percutaneous radiofrequency ablation or biopsy of hepatic lesions. This prospective study was approved by the institutional review board, and all patients gave written informed consent. Twenty-two patients (male/female, n = 18/n = 4; age, 61.0 ± 7.7 years) who were referred for planning US to assess the feasibility of radiofrequency ablation (n = 21) or biopsy (n = 1) for focal hepatic lesions were included. One experienced radiologist performed the two types of image fusion methods in each patient. The performance of auto-registration and manual registration was evaluated. The accuracy of the two methods, based on measuring registration error, and the time required for image fusion for both methods were recorded using in-house software and respectively compared using the Wilcoxon signed rank test. Image fusion was successful in all patients. The registration error was not significantly different between the two methods (auto-registration: median, 3.75 mm; range, 1.0-15.8 mm vs. manual registration: median, 2.95 mm; range, 1.2-12.5 mm, p = 0.242). The time required for image fusion was significantly shorter with auto-registration than with manual registration (median, 28.5 s; range, 18-47 s, vs. median, 36.5 s; range, 14-105 s, p = 0.026). Positioning auto-registration showed promising results compared with manual registration, with similar accuracy and even shorter registration time.
The Combined Effect of Cold and Moisture on Manual Performance.
Ray, Matthew; Sanli, Elizabeth; Brown, Robert; Ennis, Kerri Ann; Carnahan, Heather
2018-02-01
Objective The aim of this study was to investigate the combined effect of cold and moisture on manual performance and tactile sensitivity. Background People working in the ocean environment often perform manual work in cold and wet conditions. Although the independent effects of cold and moisture on hand function are known, their combined effect has not been investigated. Method Participants completed sensory (Touch-Test, two-point discrimination) and motor (Purdue Pegboard, Grooved Pegboard, reef knot untying) tests in the following conditions: dry hand, wet hand, cold hand, and cold and wet hand. Results For the Purdue Pegboard and knot untying tasks, the greatest decrement in performance was observed in the cold-and-wet-hand condition, whereas the decrements seen in the cold-hand and wet-hand conditions were similar. In the Grooved Pegboard task, the performance decrements exhibited in the cold-and-wet-hand condition and the cold-hand condition were similar, whereas no decrement was observed in the wet-hand condition. Tactile sensitivity was reduced in the cold conditions for the Touch-Test but not the two-point discrimination test. The combined effect of cold and moisture led to the largest performance decrements except when intrinsic object properties helped with grasp maintenance. The independent effects of cold and moisture on manual performance were comparable. Application Tools and equipment for use in the cold ocean environment should be designed to minimize the effects of cold and moisture on manual performance by including object properties that enhance grasp maintenance and minimize the fine-dexterity requirements.
Bouchoucha, Mongia; Akrout, Mouna; Bellali, Hédia; Bouchoucha, Rim; Tarhouni, Fadwa; Mansour, Abderraouf Ben; Zouari, Béchir
2016-01-01
Estimation of food portion sizes has always been a challenge in dietary studies on free-living individuals. The aim of this work was to develop and validate a food photography manual to improve the accuracy of the estimated size of consumed food portions. A manual was compiled from digital photos of foods commonly consumed by the Tunisian population. The food was cooked and weighed before taking digital photographs of three portion sizes. The manual was validated by comparing the method of 24-hour recall (using photos) to the reference method [food weighing (FW)]. In both the methods, the comparison focused on food intake amounts as well as nutritional issues. Validity was assessed by Bland-Altman limits of agreement. In total, 31 male and female volunteers aged 9-89 participated in the study. We focused on eight food categories and compared their estimated amounts (using the 24-hour recall method) to those actually consumed (using FW). Animal products and sweets were underestimated, whereas pasta, bread, vegetables, fruits, and dairy products were overestimated. However, the difference between the two methods is not statistically significant except for pasta (p<0.05) and dairy products (p<0.05). The coefficient of correlation between the two methods is highly significant, ranging from 0.876 for pasta to 0.989 for dairy products. Nutrient intake calculated for both methods showed insignificant differences except for fat (p<0.001) and dietary fiber (p<0.05). A highly significant correlation was observed between the two methods for all micronutrients. The test agreement highlights the lack of difference between the two methods. The difference between the 24-hour recall method using digital photos and the weighing method is acceptable. Our findings indicate that the food photography manual can be a useful tool for quantifying food portion sizes in epidemiological dietary surveys.
40 CFR 63.5160 - What performance tests must I complete?
Code of Federal Regulations, 2010 CFR
2010-07-01
... solvent recovery system and you choose to comply by means of a monthly liquid-liquid material balance. (b... Method 3B, the manual method for measuring the oxygen, carbon dioxide, and carbon monoxide content of... hour (h). Cc=concentration of organic compounds as carbon in the vent gas, as determined by Method 25...
40 CFR 63.5160 - What performance tests must I complete?
Code of Federal Regulations, 2011 CFR
2011-07-01
... solvent recovery system and you choose to comply by means of a monthly liquid-liquid material balance. (b... Method 3B, the manual method for measuring the oxygen, carbon dioxide, and carbon monoxide content of... hour (h). Cc=concentration of organic compounds as carbon in the vent gas, as determined by Method 25...
40 CFR 63.5160 - What performance tests must I complete?
Code of Federal Regulations, 2013 CFR
2013-07-01
... solvent recovery system and you choose to comply by means of a monthly liquid-liquid material balance. (b... Method 3B, the manual method for measuring the oxygen, carbon dioxide, and carbon monoxide content of... hour (h). Cc=concentration of organic compounds as carbon in the vent gas, as determined by Method 25...
40 CFR 63.5160 - What performance tests must I complete?
Code of Federal Regulations, 2012 CFR
2012-07-01
... solvent recovery system and you choose to comply by means of a monthly liquid-liquid material balance. (b... Method 3B, the manual method for measuring the oxygen, carbon dioxide, and carbon monoxide content of... hour (h). Cc=concentration of organic compounds as carbon in the vent gas, as determined by Method 25...
40 CFR 63.5160 - What performance tests must I complete?
Code of Federal Regulations, 2014 CFR
2014-07-01
... solvent recovery system and you choose to comply by means of a monthly liquid-liquid material balance. (b... Method 3B, the manual method for measuring the oxygen, carbon dioxide, and carbon monoxide content of... hour (h). Cc = concentration of organic compounds as carbon in the vent gas, as determined by Method 25...
Vajawat, Mayuri; Deepika, P. C.; Kumar, Vijay; Rajeshwari, P.
2015-01-01
Aim: To compare the efficacy of powered toothbrushes in improving gingival health and reducing salivary red complex counts as compared to manual toothbrushes, among autistic individuals. Materials and Methods: Forty autistics was selected. Test group received powered toothbrushes, and control group received manual toothbrushes. Plaque index and gingival index were recorded. Unstimulated saliva was collected for analysis of red complex organisms using polymerase chain reaction. Results: A statistically significant reduction in the plaque scores was seen over a period of 12 weeks in both the groups (P < 0.001 for tests and P = 0.002 for controls). This reduction was statistically more significant in the test group (P = 0.024). A statistically significant reduction in the gingival scores was seen over a period of 12 weeks in both the groups (P < 0.001 for tests and P = 0.001 for controls). This reduction was statistically more significant in the test group (P = 0.042). No statistically significant reduction in the detection rate of red complex organisms were seen at 4 weeks in both the groups. Conclusion: Powered toothbrushes result in a significant overall improvement in gingival health when constant reinforcement of oral hygiene instructions is given. PMID:26681855
DOE Office of Scientific and Technical Information (OSTI.GOV)
Cornelis, F.; Takaki, H.; Laskhmanan, M.
PurposeTo compare CT fluoroscopy-guided manual and CT-guided robotic positioning system (RPS)-assisted needle placement by experienced IR physicians to targets in swine liver.Materials and MethodsManual and RPS-assisted needle placement was performed by six experienced IR physicians to four 5 mm fiducial seeds placed in swine liver (n = 6). Placement performance was assessed for placement accuracy, procedure time, number of confirmatory scans, needle manipulations, and procedure radiation dose. Intra-modality difference in performance for each physician was assessed using paired t test. Inter-physician performance variation for each modality was analyzed using Kruskal–Wallis test.ResultsPaired comparison of manual and RPS-assisted placements to a target by the samemore » physician indicated accuracy outcomes was not statistically different (manual: 4.53 mm; RPS: 4.66 mm; p = 0.41), but manual placement resulted in higher total radiation dose (manual: 1075.77 mGy/cm; RPS: 636.4 mGy/cm; p = 0.03), required more confirmation scans (manual: 6.6; RPS: 1.6; p < 0.0001) and needle manipulations (manual: 4.6; RPS: 0.4; p < 0.0001). Procedure time for RPS was longer than manual placement (manual: 6.12 min; RPS: 9.7 min; p = 0.0003). Comparison of inter-physician performance during manual placement indicated significant differences in the time taken to complete placements (p = 0.008) and number of repositions (p = 0.04) but not in other study measures (p > 0.05). Comparison of inter-physician performance during RPS-assisted placement suggested statistically significant differences in procedure time (p = 0.02) and not in other study measures (p > 0.05).ConclusionsCT-guided RPS-assisted needle placement reduced radiation dose, number of confirmatory scans, and needle manipulations when compared to manual needle placement by experienced IR physicians, with equivalent accuracy.« less
Assessment Methods for Restrictions in Manual Dexterity: Suitability for Exposure to the Cold
2009-10-01
palm is goat leather. The thermal comfort range of the gloves had been described recently (Zimmermann et al. 2008). Figure 1: Military five...sufficient to maintain the thermal comfort of the body. In the screw/bolt skill test restrictions in manual dexterity due to mechanical and haptical...temperature of the human body. J. Appl. Physiol. 19: 531-533 (1964). [10] Zimmermann, C., Uedelhoven, W. H., Kurz, B., Glitz, K. J.: Thermal comfort range
Gaburro, Julie; Duchemin, Jean-Bernard; Paradkar, Prasad N; Nahavandi, Saeid; Bhatti, Asim
2016-11-18
Widespread in the tropics, the mosquito Aedes aegypti is an important vector of many viruses, posing a significant threat to human health. Vector monitoring often requires fecundity estimation by counting eggs laid by female mosquitoes. Traditionally, manual data analyses have been used but this requires a lot of effort and is the methods are prone to errors. An easy tool to assess the number of eggs laid would facilitate experimentation and vector control operations. This study introduces a built-in software called ICount allowing automatic egg counting of the mosquito vector, Aedes aegypti. ICount egg estimation compared to manual counting is statistically equivalent, making the software effective for automatic and semi-automatic data analysis. This technique also allows rapid analysis compared to manual methods. Finally, the software has been used to assess p-cresol oviposition choices under laboratory conditions in order to test the system with different egg densities. ICount is a powerful tool for fast and precise egg count analysis, freeing experimenters from manual data processing. Software access is free and its user-friendly interface allows easy use by non-experts. Its efficiency has been tested in our laboratory with oviposition dual choices of Aedes aegypti females. The next step will be the development of a mobile application, based on the ICount platform, for vector monitoring surveys in the field.
A comparison of manual and quantitative elbow strength testing.
Shahgholi, Leili; Bengtson, Keith A; Bishop, Allen T; Shin, Alexander Y; Spinner, Robert J; Basford, Jeffrey R; Kaufman, Kenton R
2012-10-01
The aim of this study was to compare the clinical ratings of elbow strength obtained by skilled clinicians with objective strength measurement obtained through quantitative testing. A retrospective comparison of subject clinical records with quantitative strength testing results in a motion analysis laboratory was conducted. A total of 110 individuals between the ages of 8 and 65 yrs with traumatic brachial plexus injuries were identified. Patients underwent manual muscle strength testing as assessed on the 5-point British Medical Research Council Scale (5/5, normal; 0/5, absent) and quantitative elbow flexion and extension strength measurements. A total of 92 subjects had elbow flexion testing. Half of the subjects clinically assessed as having normal (5/5) elbow flexion strength on manual muscle testing exhibited less than 42% of their age-expected strength on quantitative testing. Eighty-four subjects had elbow extension strength testing. Similarly, half of those displaying normal elbow extension strength on manual muscle testing were found to have less than 62% of their age-expected values on quantitative testing. Significant differences between manual muscle testing and quantitative findings were not detected for the lesser (0-4) strength grades. Manual muscle testing, even when performed by experienced clinicians, may be more misleading than expected for subjects graded as having normal (5/5) strength. Manual muscle testing estimates for the lesser strength grades (1-4/5) seem reasonably accurate.
NASA Technical Reports Server (NTRS)
Mullally, Fergal
2017-01-01
We present an automated method of identifying background eclipsing binaries masquerading as planet candidates in the Kepler planet candidate catalogs. We codify the manual vetting process for Kepler Objects of Interest (KOIs) described in Bryson et al. (2013) with a series of measurements and tests that can be performed algorithmically. We compare our automated results with a sample of manually vetted KOIs from the catalog of Burke et al. (2014) and find excellent agreement. We test the performance on a set of simulated transits and find our algorithm correctly identifies simulated false positives approximately 50 of the time, and correctly identifies 99 of simulated planet candidates.
FIELD OPERATIONS AND METHODS FOR MEASURING THE ECOLOGICAL CONDITION OF WADEABLE STREAMS
The methods and instructions for field operations presented in this manual for surveys of wadeable streams were developed and tested during 5 years of pilot and demonstration projects (1993 through 1997). These projects were conducted under the sponsorship of the U.S. Environment...
Kabir, Md Iqbal; Rahman, Md Bayzidur; Smith, Wayne; Lusha, Mirza Afreen Fatima; Milton, Abul Hasnat
2015-01-01
Background Bangladesh is one of the most vulnerable countries to climate change. People are getting educated at different levels on how to deal with potential impacts. One such educational mode was the preparation of a school manual, for high school students on climate change and health protection endorsed by the National Curriculum and Textbook Board, which is based on a 2008 World Health Organization manual. The objective of this study was to test the effectiveness of the manual in increasing the knowledge level of the school children about climate change and health adaptation. Methods This cluster randomized intervention trial involved 60 schools throughout Bangladesh, with 3293 secondary school students participating. School upazilas (sub-districts) were randomised into intervention and control groups, and two schools from each upazila were randomly selected. All year seven students from both groups of schools sat for a pre-test of 30 short questions of binary response. A total of 1515 students from 30 intervention schools received the intervention through classroom training based on the school manual and 1778 students of the 30 control schools did not get the manual but a leaflet on climate change and health issues. Six months later, a post-intervention test of the same questionnaire used in the pre-test was performed at both intervention and control schools. The pre and post test scores were analysed along with the demographic data by using random effects model. Results None of the various school level and student level variables were significantly different between the control and intervention group. However, the intervention group had a 17.42% (95% CI: 14.45 to 20.38, P = <0.001) higher score in the post-test after adjusting for pre-test score and other covariates in a multi-level linear regression model. Conclusions These results suggest that school-based intervention for climate change and health adaptation is effective for increasing the knowledge level of school children on this topic. PMID:26252381
May, S L; May, W A; Bourdoux, P P; Pino, S; Sullivan, K M; Maberly, G F
1997-05-01
The measurement of urinary iodine in population-based surveys provides a biological indicator of the severity of iodine-deficiency disorders. We describe the steps performed to validate a simple, inexpensive, manual urinary iodine acid digestion method, and compare the results using this method with those of other urinary iodine methods. Initially, basic performance characteristics were evaluated: the average recovery of added iodine was 100.4 +/- 8.7% (mean +/- SD), within-assay precision (CV) over the assay range 0-0.95 mumol/L (0-12 micrograms/dL) was < 6%, between-assay precision over the same range was < 12%, and assay sensitivity was 0.05 mumol/L (0.6 microgram/dL). There were no apparent effects on the method by thiocyanate, a known interfering substance. In a comparison with five other methods performed in four different laboratories, samples were collected to test the method performance over a wide range of urinary iodine values (0.04-3.7 mumol/L, or 0.5-47 micrograms/dL). There was a high correlation between all methods and the interpretation of the results was consistent. We conclude that the simple, manual acid digestion method is suitable for urinary iodine analysis.
Electrostatic discharge control for STDN stations
NASA Technical Reports Server (NTRS)
Mckiernan, J.
1983-01-01
This manual defines the requirements and control methods necessary to control the effect of electrostatic discharges that damage or destroy electronic equipment components. Test procedures for measuring the effectiveness of the control are included.
Alfa, M J; Nemes, R; Olson, N; Mulaire, A
2006-08-01
Most reusable biopsy forceps and all of the currently available single-use biopsy forceps do not have a port that allows fluid flow down the inner tubular shaft of the device. Reusable biopsy forceps are widely used and reprocessed in healthcare facilities, and single-use biopsy forceps are reprocessed either in-house (eg, in Canada and Japan) or by third-party reprocessors (eg, in the United States). The objective of this study was to determine the cleaning efficacy of automated narrow-lumen sonic irrigation cleaning, sonication-only cleaning, and manual cleaning for biopsy forceps. A simulated-use study was performed by inoculating the inner channel of single-use biopsy forceps with artificial test soil containing both Enterococcus faecalis and Geobacillus stearothermophilus at concentrations of 10(6) colony-forming units per milliliter. The cleaning methods evaluated were manual cleaning, sonication-only cleaning, and "retroflush" cleaning by an automated narrow-lumen irrigator. Bioburden and organic soil reduction after washing was evaluated. Forceps used in biopsies of patients were also tested to determine the worst-case soiling levels. Only retroflush irrigation cleaning could effectively remove material from within the shaft portion of the biopsy forceps: it achieved an average reduction of more than 95% in levels of protein, hemoglobin, carbohydrate, and endotoxin. However, even this method of cleaning was not totally effective, as only a 2 log10 reduction in bioburden could be achieved, and there were low residual levels of hemoglobin and carbohydrate. The data from this evaluation indicate that manual and sonication-only cleaning methods for biopsy forceps were totally ineffective in removing material from within the biopsy forceps. Even the use of retroflush cleaning was not totally effective. These findings suggest that in-hospital reprocessing of biopsy forceps with currently available equipment and cleaning methods is suboptimal.
Semi-Automated Trajectory Analysis of Deep Ballistic Penetrating Brain Injury
Folio, Les; Solomon, Jeffrey; Biassou, Nadia; Fischer, Tatjana; Dworzak, Jenny; Raymont, Vanessa; Sinaii, Ninet; Wassermann, Eric M.; Grafman, Jordan
2016-01-01
Background Penetrating head injuries (PHIs) are common in combat operations and most have visible wound paths on computed tomography (CT). Objective We assess agreement between an automated trajectory analysis-based assessment of brain injury and manual tracings of encephalomalacia on CT. Methods We analyzed 80 head CTs with ballistic PHI from the Institutional Review Board approved Vietnam head injury registry. Anatomic reports were generated from spatial coordinates of projectile entrance and terminal fragment location. These were compared to manual tracings of the regions of encephalomalacia. Dice’s similarity coefficients, kappa, sensitivities, and specificities were calculated to assess agreement. Times required for case analysis were also compared. Results Results show high specificity of anatomic regions identified on CT with semiautomated anatomical estimates and manual tracings of tissue damage. Radiologist’s and medical students’ anatomic region reports were similar (Kappa 0.8, t-test p < 0.001). Region of probable injury modeling of involved brain structures was sensitive (0.7) and specific (0.9) compared with manually traced structures. Semiautomated analysis was 9-fold faster than manual tracings. Conclusion Our region of probable injury spatial model approximates anatomical regions of encephalomalacia from ballistic PHI with time-saving over manual methods. Results show potential for automated anatomical reporting as an adjunct to current practice of radiologist/neurosurgical review of brain injury by penetrating projectiles. PMID:23707123
46 CFR 130.480 - Test procedure and operations manual.
Code of Federal Regulations, 2010 CFR
2010-10-01
... 46 Shipping 4 2010-10-01 2010-10-01 false Test procedure and operations manual. 130.480 Section... VESSEL CONTROL, AND MISCELLANEOUS EQUIPMENT AND SYSTEMS Automation of Unattended Machinery Spaces § 130.480 Test procedure and operations manual. (a) A procedure for tests to be conducted on automated...
A new computer-based Farnsworth Munsell 100-hue test for evaluation of color vision.
Ghose, Supriyo; Parmar, Twinkle; Dada, Tanuj; Vanathi, Murugesan; Sharma, Sourabh
2014-08-01
To evaluate a computer-based Farnsworth-Munsell (FM) 100-hue test and compare it with a manual FM 100-hue test in normal and congenital color-deficient individuals. Fifty color defective subjects and 200 normal subjects with a best-corrected visual acuity ≥ 6/12 were compared using a standard manual FM 100-hue test and a computer-based FM 100-hue test under standard operating conditions as recommended by the manufacturer after initial trial testing. Parameters evaluated were total error scores (TES), type of defect and testing time. Pearson's correlation coefficient was used to determine the relationship between the test scores. Cohen's kappa was used to assess agreement of color defect classification between the two tests. A receiver operating characteristic curve was used to determine the optimal cut-off score for the computer-based FM 100-hue test. The mean time was 16 ± 1.5 (range 6-20) min for the manual FM 100-hue test and 7.4 ± 1.4 (range 5-13) min for the computer-based FM 100-hue test, thus reducing testing time to <50 % (p < 0.05). For grading color discrimination, Pearson's correlation coefficient for TES between the two tests was 0.91 (p < 0.001). For color defect classification, Cohen's agreement coefficient was 0.98 (p < 0.01). The computer-based FM 100-hue is an effective and rapid method for detecting, classifying and grading color vision anomalies.
Evaluation of an artificial intelligence guided inverse planning system: clinical case study.
Yan, Hui; Yin, Fang-Fang; Willett, Christopher
2007-04-01
An artificial intelligence (AI) guided method for parameter adjustment of inverse planning was implemented on a commercial inverse treatment planning system. For evaluation purpose, four typical clinical cases were tested and the results from both plans achieved by automated and manual methods were compared. The procedure of parameter adjustment mainly consists of three major loops. Each loop is in charge of modifying parameters of one category, which is carried out by a specially customized fuzzy inference system. A physician prescribed multiple constraints for a selected volume were adopted to account for the tradeoff between prescription dose to the PTV and dose-volume constraints for critical organs. The searching process for an optimal parameter combination began with the first constraint, and proceeds to the next until a plan with acceptable dose was achieved. The initial setup of the plan parameters was the same for each case and was adjusted independently by both manual and automated methods. After the parameters of one category were updated, the intensity maps of all fields were re-optimized and the plan dose was subsequently re-calculated. When final plan arrived, the dose statistics were calculated from both plans and compared. For planned target volume (PTV), the dose for 95% volume is up to 10% higher in plans using the automated method than those using the manual method. For critical organs, an average decrease of the plan dose was achieved. However, the automated method cannot improve the plan dose for some critical organs due to limitations of the inference rules currently employed. For normal tissue, there was no significant difference between plan doses achieved by either automated or manual method. With the application of AI-guided method, the basic parameter adjustment task can be accomplished automatically and a comparable plan dose was achieved in comparison with that achieved by the manual method. Future improvements to incorporate case-specific inference rules are essential to fully automate the inverse planning process.
Majdak, Piotr; Goupell, Matthew J; Laback, Bernhard
2010-02-01
The ability to localize sound sources in three-dimensional space was tested in humans. In Experiment 1, naive subjects listened to noises filtered with subject-specific head-related transfer functions. The tested conditions included the pointing method (head or manual pointing) and the visual environment (VE; darkness or virtual VE). The localization performance was not significantly different between the pointing methods. The virtual VE significantly improved the horizontal precision and reduced the number of front-back confusions. These results show the benefit of using a virtual VE in sound localization tasks. In Experiment 2, subjects were provided with sound localization training. Over the course of training, the performance improved for all subjects, with the largest improvements occurring during the first 400 trials. The improvements beyond the first 400 trials were smaller. After the training, there was still no significant effect of pointing method, showing that the choice of either head- or manual-pointing method plays a minor role in sound localization performance. The results of Experiment 2 reinforce the importance of perceptual training for at least 400 trials in sound localization studies.
40 CFR 63.3360 - What performance tests must I conduct?
Code of Federal Regulations, 2012 CFR
2012-07-01
... monthly liquid-liquid material balance. (c) Organic HAP content. If you determine compliance with the... alternative to Method 3B the manual method for measuring the oxygen, carbon dioxide, and carbon monoxide... meters (dscm)/h. Cc = Concentration of organic compounds as carbon, ppmv. 12.0 = Molecular weight of...
40 CFR 63.3360 - What performance tests must I conduct?
Code of Federal Regulations, 2013 CFR
2013-07-01
... monthly liquid-liquid material balance. (c) Organic HAP content. If you determine compliance with the... alternative to Method 3B the manual method for measuring the oxygen, carbon dioxide, and carbon monoxide... meters (dscm)/h. Cc = Concentration of organic compounds as carbon, ppmv. 12.0 = Molecular weight of...
40 CFR 63.3360 - What performance tests must I conduct?
Code of Federal Regulations, 2014 CFR
2014-07-01
... monthly liquid-liquid material balance. (c) Organic HAP content. If you determine compliance with the... alternative to Method 3B the manual method for measuring the oxygen, carbon dioxide, and carbon monoxide... meters (dscm)/h. Cc = Concentration of organic compounds as carbon, ppmv. 12.0 = Molecular weight of...
Usefulness of a rotation-revolution mixer for mixing powder-liquid reline material.
Yamaga, Yoshio; Kanatani, Mitsugu; Nomura, Shuichi
2015-01-01
The purpose of this study was to evaluate the distribution of bubbles, degree of mixing, flowability and mechanical strength of powder-liquid reline material by manually and with a rotation-revolution (planetary) mixer, and to determine the usefulness of a rotation-revolution mixer for this application. Powder-liquid reline material (Mild Rebaron, GC, Tokyo, Japan) was mixed with a powder to liquid ratio of 1:0.62 according to the manufacturer's instruction. Two methods were used to mix it: mixed by manually ("manual-mixing") and automatically with a rotation-revolution mixer (Super Rakuneru Fine, GC, Tokyo, Japan; "automatic-mixing"). Disc-shaped specimens, 30 mm in diameter and 1.0mm in thickness, were used to observe the distribution of bubbles in at 10× magnifications. Flowability tests were carried out according to the JIS T6521 for denture base hard reline materials. A three point bending test was carried out by a universal testing machine. Elastic modulus and flexural stress at the proportional limit were calculated. A median of 4 bubbles and inhomogeneous were observed in manual-mixed specimens. However, no bubbles and homogeneous were observed in automatic-mixed specimens. Flowability was within the JIS range in all mixing conditions and did not differ significantly across conditions. The elastic modulus was the same for manual-mixed and automatic-mixed specimens. On the other hand, the flexural stress at the proportional limit differed significantly between manual-mixed and automatic-mixed specimens. The results confirm that rotation-revolution mixer is useful for mixing powder-liquid reline material. Automatic-mixing may be recommended for clinical practice. Copyright © 2014 Japan Prosthodontic Society. Published by Elsevier Ltd. All rights reserved.
Foot Pedals for Spacecraft Manual Control
NASA Technical Reports Server (NTRS)
Love, Stanley G.; Morin, Lee M.; McCabe, Mary
2010-01-01
Fifty years ago, NASA decided that the cockpit controls in spacecraft should be like the ones in airplanes. But controls based on the stick and rudder may not be best way to manually control a vehicle in space. A different method is based on submersible vehicles controlled with foot pedals. A new pilot can learn the sub's control scheme in minutes and drive it hands-free. We are building a pair of foot pedals for spacecraft control, and will test them in a spacecraft flight simulator.
NASA Astrophysics Data System (ADS)
Noble, Clifford Elliott, II
2002-09-01
The problem. The purpose of this study was to investigate the ability of three single-task instruments---(a) the Test of English as a Foreign Language, (b) the Aviation Test of Spoken English, and (c) the Single Manual-Tracking Test---and three dual-task instruments---(a) the Concurrent Manual-Tracking and Communication Test, (b) the Certified Flight Instructor's Test, and (c) the Simulation-Based English Test---to predict the language performance of 10 Chinese student pilots speaking English as a second language when operating single-engine and multiengine aircraft within American airspace. Method. This research implemented a correlational design to investigate the ability of the six described instruments to predict the mean score of the criterion evaluation, which was the Examiner's Test. This test assessed the oral communication skill of student pilots on the flight portion of the terminal checkride in the Piper Cadet, Piper Seminole, and Beechcraft King Air airplanes. Results. Data from the Single Manual-Tracking Test, as well as the Concurrent Manual-Tracking and Communication Test, were discarded due to performance ceiling effects. Hypothesis 1, which stated that the average correlation between the mean scores of the dual-task evaluations and that of the Examiner's Test would predict the mean score of the criterion evaluation with a greater degree of accuracy than that of single-task evaluations, was not supported. Hypothesis 2, which stated that the correlation between the mean scores of the participants on the Simulation-Based English Test and the Examiner's Test would predict the mean score of the criterion evaluation with a greater degree of accuracy than that of all single- and dual-task evaluations, was also not supported. The findings suggest that single- and dual-task assessments administered after initial flight training are equivalent predictors of language performance when piloting single-engine and multiengine aircraft.
AM2 Brickwork Pattern Evaluation
2016-12-01
pavement applications. Designation : D 6951. West Consho- hocken, PA: ASTM International. ASTM International. 2010a. Standard test method for in-place... design . This report provides test results for each evaluation and discussions comparing their perfor- mance to previous tests conducted under similar... designated by other authorized documents. DESTRUCTION NOTICE - For classified documents, follow the procedures in DOD5200.22-M, Industrial Security Manual
Manual tracing versus smartphone application (app) tracing: a comparative study.
Sayar, Gülşilay; Kilinc, Delal Dara
2017-11-01
This study aimed to compare the results of conventional manual cephalometric tracing with those acquired with smartphone application cephalometric tracing. The cephalometric radiographs of 55 patients (25 females and 30 males) were traced via the manual and app methods and were subsequently examined with Steiner's analysis. Five skeletal measurements, five dental measurements and two soft tissue measurements were managed based on 21 landmarks. The durations of the performances of the two methods were also compared. SNA (Sella, Nasion, A point angle) and SNB (Sella, Nasion, B point angle) values for the manual method were statistically lower (p < .001) than those for the app method. The ANB value for the manual method was statistically lower than that of app method. L1-NB (°) and upper lip protrusion values for the manual method were statistically higher than those for the app method. Go-GN/SN, U1-NA (°) and U1-NA (mm) values for manual method were statistically lower than those for the app method. No differences between the two methods were found in the L1-NB (mm), occlusal plane to SN, interincisal angle or lower lip protrusion values. Although statistically significant differences were found between the two methods, the cephalometric tracing proceeded faster with the app method than with the manual method.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Cardenas, C; The University of Texas Graduate School of Biomedical Sciences, Houston, TX; Wong, A
Purpose: To develop and test population-based machine learning algorithms for delineating high-dose clinical target volumes (CTVs) in H&N tumors. Automating and standardizing the contouring of CTVs can reduce both physician contouring time and inter-physician variability, which is one of the largest sources of uncertainty in H&N radiotherapy. Methods: Twenty-five node-negative patients treated with definitive radiotherapy were selected (6 right base of tongue, 11 left and 9 right tonsil). All patients had GTV and CTVs manually contoured by an experienced radiation oncologist prior to treatment. This contouring process, which is driven by anatomical, pathological, and patient specific information, typically results inmore » non-uniform margin expansions about the GTV. Therefore, we tested two methods to delineate high-dose CTV given a manually-contoured GTV: (1) regression-support vector machines(SVM) and (2) classification-SVM. These models were trained and tested on each patient group using leave-one-out cross-validation. The volume difference(VD) and Dice similarity coefficient(DSC) between the manual and auto-contoured CTV were calculated to evaluate the results. Distances from GTV-to-CTV were computed about each patient’s GTV and these distances, in addition to distances from GTV to surrounding anatomy in the expansion direction, were utilized in the regression-SVM method. The classification-SVM method used categorical voxel-information (GTV, selected anatomical structures, else) from a 3×3×3cm3 ROI centered about the voxel to classify voxels as CTV. Results: Volumes for the auto-contoured CTVs ranged from 17.1 to 149.1cc and 17.4 to 151.9cc; the average(range) VD between manual and auto-contoured CTV were 0.93 (0.48–1.59) and 1.16(0.48–1.97); while average(range) DSC values were 0.75(0.59–0.88) and 0.74(0.59–0.81) for the regression-SVM and classification-SVM methods, respectively. Conclusion: We developed two novel machine learning methods to delineate high-dose CTV for H&N patients. Both methods showed promising results that hint to a solution to the standardization of the contouring process of clinical target volumes. Varian Medical Systems grant.« less
Price, Randi; Wan, Ping
2010-01-01
A potentiometric titration for determining the quaternary ammonium compounds (QAC) commonly found in antimicrobial products was validated by a single laboratory. Traditionally, QACs were determined by using a biphasic (chloroform and water) manual titration procedure. Because of safety considerations regarding chloroform, as well as the subjectivity of color indicator-based manual titration determinations, an automatic potentiometric titration procedure was tested with quaternary nitrogen product formulations. By using the Metrohm Titrando system coupled with an ionic surfactant electrode and an Ag/AgCl reference electrode, titrations were performed with various QAC-containing formulation products/matrixes; a standard sodium lauryl sulfate solution was used as the titrant. Results for the products tested are sufficiently reproducible and accurate for the purpose of regulatory product enforcement. The robustness of the method was measured by varying pH levels, as well as by comparing buffered versus unbuffered titration systems. A quantitation range of 1-1000 ppm quaternary nitrogen was established. Eight commercially available antimicrobial products covering a variety of matrixes were assayed; the results obtained were comparable to those obtained by the manual titration method. Recoveries of 94 to 104% were obtained for spiked samples.
Ultrasonic Testing, Aviation Quality Control (Advanced): 9227.03.
ERIC Educational Resources Information Center
Dade County Public Schools, Miami, FL.
This unit of instruction covers the theory of ultrasonic sound, methods of applying soundwaves to test specimens and interpreting results, calibrating the ultrasonic equipment, and the use of standards. Study periods, group discussions, and extensive use of textbooks and training manuals are to be used. These are listed along with references and…
Rapid enumeration of viable bacteria by image analysis
NASA Technical Reports Server (NTRS)
Singh, A.; Pyle, B. H.; McFeters, G. A.
1989-01-01
A direct viable counting method for enumerating viable bacteria was modified and made compatible with image analysis. A comparison was made between viable cell counts determined by the spread plate method and direct viable counts obtained using epifluorescence microscopy either manually or by automatic image analysis. Cultures of Escherichia coli, Salmonella typhimurium, Vibrio cholerae, Yersinia enterocolitica and Pseudomonas aeruginosa were incubated at 35 degrees C in a dilute nutrient medium containing nalidixic acid. Filtered samples were stained for epifluorescence microscopy and analysed manually as well as by image analysis. Cells enlarged after incubation were considered viable. The viable cell counts determined using image analysis were higher than those obtained by either the direct manual count of viable cells or spread plate methods. The volume of sample filtered or the number of cells in the original sample did not influence the efficiency of the method. However, the optimal concentration of nalidixic acid (2.5-20 micrograms ml-1) and length of incubation (4-8 h) varied with the culture tested. The results of this study showed that under optimal conditions, the modification of the direct viable count method in combination with image analysis microscopy provided an efficient and quantitative technique for counting viable bacteria in a short time.
Dötsch, J; Demirakça, S; Hahn, D; Katz, N; Kühl, P G; Rascher, W
1999-06-01
During nitric oxide inhalation, methemoglobinemia needs to be monitored. We compared six commercially available instruments and one manual method for methemoglobin measurements. In addition, we studied whether and to what degree methylene blue interferes with methemoglobin measurements. In vitro methodologic study. Research laboratory in a university hospital. Five healthy volunteers from whom red blood cells were obtained. Methemoglobinemia was generated in a red blood cell suspension by nitric oxide; methemoglobin was measured with six commercial instruments and one manual photometric method to calculate variation coefficients and to determine the differences between the devices. Methemoglobin was measured with and without the addition of methylene blue with two instruments. Measurements were performed immediately after the addition of methylene blue. All six commercially available instruments had variation coefficients of <0.1 at methemoglobin concentrations of 5%, whereas the manual photometric method did not reach a variation coefficient of <0.1 at 8% of methemoglobin. Apart from two devices that measured slightly but significantly higher methemoglobin levels, all instruments measured similar values of methemoglobin when the same samples were determined simultaneously. Higher concentrations of methylene blue (10, 40, 100 microM) reduced substantially the apparent concentrations of methemoglobin. Interference by methylene blue was most pronounced at low methemoglobin levels. With some limitations, all commercial instruments that were tested performed adequately for the monitoring of methemoglobinemia. Methylene blue interferes with the methemoglobin measurements in a dose-dependent manner.
Truett, April A; Letizia, Andrew; Malyangu, Evans; Sinyangwe, Frank; Morales, Brandi N; Crum, Nancy F; Crowe, Suzanne M
2006-02-01
Manual CD4 tests such as Dynal T4 Quant (Dynabeads, Dynal Biotech, Oslo, Norway) are less expensive alternatives to flow cytometry in resource-limited countries. Whereas blood preservatives have proven useful for stabilizing blood samples to allow delayed CD4 testing by flow cytometry, they have not been verified for manual tests. A method for preservation of blood prior to manual CD4 testing is needed for long-distance transport or sample batching. Blood from HIV-positive Zambian military beneficiaries was mixed (1:1) with Cyto-Chex (Streck Laboratories, La Vista, NE) blood preservative, and the blood was stored at refrigerated, ambient, and incubator (37 degrees C) temperatures prior to Dynabeads CD4 testing at 0, 3, 6, and 9 days after collection. Baseline flow cytometry and Dynabeads testing without preservative were performed for comparison. Twenty-seven patient samples were analyzed. Dynabeads vs. flow cytometry had a correlation coefficient (r) of 0.84. There was excellent correlation (r = 0.96) between baseline Dynabeads testing and Cyto-Chex-preserved samples. Refrigerated samples showed strong correlation with baseline Dynabeads (r = 0.93-0.95) on days 3, 6, and 9 without decline in CD4 count (P = 0.73). Samples stored at ambient temperature yielded inferior results (r = 0.76-0.81), with a significant decline in CD4 count by day 3 (P < 0.001). The incubator arm had especially poor correlation (r = 0.30-0.49). Addition of Cyto-Chex to peripheral blood (1:1) adequately preserves refrigerated blood samples for up to 9 days for subsequent testing with Dynabeads CD4 test. Cyto-Chex, however, cannot be recommended for delayed Dynabeads CD4 testing with storage at 37 degrees C or ambient temperatures in tropical areas similar to the site of this study.
NASA Astrophysics Data System (ADS)
Albrecht, F.; Hölbling, D.; Friedl, B.
2017-09-01
Landslide mapping benefits from the ever increasing availability of Earth Observation (EO) data resulting from programmes like the Copernicus Sentinel missions and improved infrastructure for data access. However, there arises the need for improved automated landslide information extraction processes from EO data while the dominant method is still manual delineation. Object-based image analysis (OBIA) provides the means for the fast and efficient extraction of landslide information. To prove its quality, automated results are often compared to manually delineated landslide maps. Although there is awareness of the uncertainties inherent in manual delineations, there is a lack of understanding how they affect the levels of agreement in a direct comparison of OBIA-derived landslide maps and manually derived landslide maps. In order to provide an improved reference, we present a fuzzy approach for the manual delineation of landslides on optical satellite images, thereby making the inherent uncertainties of the delineation explicit. The fuzzy manual delineation and the OBIA classification are compared by accuracy metrics accepted in the remote sensing community. We have tested this approach for high resolution (HR) satellite images of three large landslides in Austria and Italy. We were able to show that the deviation of the OBIA result from the manual delineation can mainly be attributed to the uncertainty inherent in the manual delineation process, a relevant issue for the design of validation processes for OBIA-derived landslide maps.
NASA Astrophysics Data System (ADS)
Lizarelli, Rosane F. Z.; Ferreira, Zulene A.; Torquato, Tatiana M.; Sampaio, Jose E. C.; Bagnato, Vanderlei S.
2000-03-01
One of the most important difficulty in the periodontal disease treatment resides in the impossibility of decontamination of roots just affected by the periodontal disease through mechanical tools. Manual dental scaling results in the amorphous material without continuity solution due to the dental cut, denominated smear layer. The main purpose of the present study was to evaluate the structure of the radicular surface using two methods for periodontal treatments: manual and mechanical associated to the irrigation with water and with EDTA (ethylene diamine tetracycline acid), followed by the application of the Er:YAG laser or the same without laser. Thirty teeth were selected with periodontal involvement. The radicular surface was scraped with ultrasound and planed vigorously, with manual instrumentation. The teeth were divided ramdomically in several groups: GI -- control, just manual instrumentation and water irrigation; GII -- manual instrumentation, EDTA irrigation; GIII -- manual instrumentation, EDTA irrigation, Er:YAG laser irradiation; GIV -- manual instrumentation, laser irradiation; and, GV -- manual instrumentation, laser irradiation and EDTA. Kruskall Wallis statistical test was applied and shows that there was not significance difference at the level of 5% among the five groups, however, when the groups were compared in pairs, GII X GIV and GII X GV shows difference in 5%, and GI X GII, difference at 1% level. The results show equivalence around the used methodology.
Softball for Boys and Girls. Skills Test Manual.
ERIC Educational Resources Information Center
Rikli, Roberta E., Ed.
The first section of this manual provides information on the history of softball and the development of testing for proficiency in the game. The tests in the manual cover batting, fielding ground balls, overhand throwing, and baserunning. Test norms are listed for males and females at each grade level. A review is included of proper techniques and…
Mateos-Pérez, José María; Soto-Montenegro, María Luisa; Peña-Zalbidea, Santiago; Desco, Manuel; Vaquero, Juan José
2016-02-01
We present a novel segmentation algorithm for dynamic PET studies that groups pixels according to the similarity of their time-activity curves. Sixteen mice bearing a human tumor cell line xenograft (CH-157MN) were imaged with three different (68)Ga-DOTA-peptides (DOTANOC, DOTATATE, DOTATOC) using a small animal PET-CT scanner. Regional activities (input function and tumor) were obtained after manual delineation of regions of interest over the image. The algorithm was implemented under the jClustering framework and used to extract the same regional activities as in the manual approach. The volume of distribution in the tumor was computed using the Logan linear method. A Kruskal-Wallis test was used to investigate significant differences between the manually and automatically obtained volumes of distribution. The algorithm successfully segmented all the studies. No significant differences were found for the same tracer across different segmentation methods. Manual delineation revealed significant differences between DOTANOC and the other two tracers (DOTANOC - DOTATATE, p=0.020; DOTANOC - DOTATOC, p=0.033). Similar differences were found using the leader-follower algorithm. An open implementation of a novel segmentation method for dynamic PET studies is presented and validated in rodent studies. It successfully replicated the manual results obtained in small-animal studies, thus making it a reliable substitute for this task and, potentially, for other dynamic segmentation procedures. Copyright © 2016 Elsevier Ltd. All rights reserved.
Rödiger, Matthias; Rinke, Sven; Ehret-Kleinau, Fenja; Pohlmeyer, Franziska; Lange, Katharina; Bürgers, Ralf
2014-01-01
PURPOSE To evaluate the effects of different abutment geometries in combination with varying luting agents and the effectiveness of different cleaning methods (prior to re-cementation) regarding the retentiveness of zirconia copings on implants. MATERIALS AND METHODS Implants were embedded in resin blocks. Three groups of titanium abutments (pre-fabricated, height: 7.5 mm, taper: 5.7°; customized-long, height: 6.79 mm, taper: 4.8°; customized-short, height: 4.31 mm, taper: 4.8°) were used for luting of CAD/CAM-fabricated zirconia copings with a semi-permanent (Telio CS) and a provisional cement (TempBond NE). Retention forces were evaluated using a universal testing machine. Furthermore, the influence of cleaning methods (manually, manually in combination with ultrasonic bath or sandblasting) prior to re-cementation with a provisional cement (TempBond NE) was investigated with the pre-fabricated titanium abutments (height: 7.5 mm, taper: 5.7°) and SEM-analysis of inner surfaces of the copings was performed. Significant differences were determined via two-way ANOVA. RESULTS Significant interactions between abutment geometry and luting agent were observed. TempBond NE showed the highest level of retentiveness on customized-long abutments, but was negatively affected by other abutment geometries. In contrast, luting with Telio CS demonstrated consistent results irrespective of the varying abutment geometries. Manual cleaning in combination with an ultrasonic bath was the only cleaning method tested prior to re-cementation that revealed retentiveness levels not inferior to primary cementation. CONCLUSION No superiority for one of the two cements could be demonstrated because their influences on retentive strength are also depending on abutment geometry. Only manual cleaning in combination with an ultrasonic bath offers retentiveness levels after re-cementation comparable to those of primary luting. PMID:25006388
NASA Astrophysics Data System (ADS)
Wang, J.; Feng, B.
2016-12-01
Impervious surface area (ISA) has long been studied as an important input into moisture flux models. In general, ISA impedes groundwater recharge, increases stormflow/flood frequency, and alters in-stream and riparian habitats. Urban area is recognized as one of the richest ISA environment. Urban ISA mapping assists flood prevention and urban planning. Hyperspectral imagery (HI), for its ability to detect subtle spectral signature, becomes an ideal candidate in urban ISA mapping. To map ISA from HI involves endmember (EM) selection. The high degree of spatial and spectral heterogeneity of urban environment puts great difficulty in this task: a compromise point is needed between the automatic degree and the good representativeness of the method. The study tested one manual and two semi-automatic EM selection strategies. The manual and the first semi-automatic methods have been widely used in EM selection. The second semi-automatic EM selection method is rather new and has been only proposed for moderate spatial resolution satellite. The manual method visually selected the EM candidates from eight landcover types in the original image. The first semi-automatic method chose the EM candidates using a threshold over the pixel purity index (PPI) map. The second semi-automatic method used the triangle shape of the HI scatter plot in the n-Dimension visualizer to identify the V-I-S (vegetation-impervious surface-soil) EM candidates: the pixels locate at the triangle points. The initial EM candidates from the three methods were further refined by three indexes (EM average RMSE, minimum average spectral angle, and count based EM selection) and generated three spectral libraries, which were used to classify the test image. Spectral angle mapper was applied. The accuracy reports for the classification results were generated. The overall accuracy are 85% for the manual method, 81% for the PPI method, and 87% for the V-I-S method. The V-I-S EM selection method performs best in this study. This fact proves the value of V-I-S EM selection method in not only moderate spatial resolution satellite image but also the more and more accessible high spatial resolution airborne image. This semi-automatic EM selection method can be adopted into a wide range of remote sensing images and provide ISA map for hydrology analysis.
Alfa, M J; Nemes, R
2004-09-01
We undertook a simulated-use study using quantitative methods to evaluate the cleaning efficacy of ported and non-ported accessory devices used in minimally invasive surgery. We chose laparoscopic scissors and forceps to represent worst-case devices which were inoculated with artificial test soil containing 10(6) cfu/mL Enterococcus faecalis and Geobacillus stearothermophilus and allowed to dry for 1 h. Cleaning was performed manually, as well as by the automated SI-Auto Narrow lumen cleaner. Manual cleaning left two- to 50-fold more soil residuals (protein, haemoglobin and carbohydrate) inside the lumen of non-ported versus ported laparoscopic accessory devices. The SI-Auto Narrow lumen cleaner was more efficient than manual cleaning and achieved >99% reduction in soil parameters in both non-ported (using retro-flushing) and ported laparoscopic devices. Only the automated cleaning of ported devices achieved 10(3)-10(4)-fold reduction in bacterial numbers. Sonication alone (no flushing of inner channel) did not effectively remove soil or organisms from the inner channel. Our findings indicate that non-ported accessory devices cannot be as reliably cleaned as ported devices regardless of the cleaning method used. If non-ported accessory devices are reprocessed, they should be cleaned using retro-flushing in an automated narrow lumen cleaner.
Methods for chemical analysis of water and wastes
DOE Office of Scientific and Technical Information (OSTI.GOV)
Not Available
1979-03-01
This manual provides test procedures approved for the monitoring of water supplies, waste discharges, and ambient waters, under the Safe Drinking Water Act, the National Pollutant Discharge Elimination System, and Ambient Monitoring Requirements of Section 106 and 208 of Public Law 92-500. The test methods have been selected to meet the needs of federal legislation and to provide guidance to laboratories engaged in the protection of human health and the aquatic environment.
Test procedure for validation of automated distress data : project summary.
DOT National Transportation Integrated Search
2017-01-01
For distress surveys of asphalt pavements, the automated results from two vendors compared reasonably closely in ratings to the manual methods. In addition, automated ratings for jointed concrete pavement show much greater inconsistency between diffe...
Teżyk, Michał; Jakubowska, Emilia; Milczewska, Kasylda; Milanowski, Bartłomiej; Voelkel, Adam; Lulek, Janina
2017-06-01
The aim of this article is to compare the gravitational powder blend loading method to the tablet press and manual loading in terms of their influence on tablets' critical quality attributes (CQA). The results of the study can be of practical relevance to the pharmaceutical industry in the area of direct compression of low-dose formulations, which could be prone to content uniformity (CU) issues. In the preliminary study, particle size distribution (PSD) and surface energy of raw materials were determined using laser diffraction method and inverse gas chromatography, respectively. For trials purpose, a formulation containing two pharmaceutical ingredients (APIs) was used. Tablet samples were collected during the compression progress to analyze their CQAs, namely assay and CU. Results obtained during trials indicate that tested direct compression powder blend is sensitive to applied powder handling method. Mild increase in both APIs content was observed during manual scooping. Gravitational approach (based on discharge into the drum) resulted in a decrease in CU, which is connected to a more pronounced assay increase at the end of tableting than in the case of manual loading. The correct design of blend transfer over single unit processes is an important issue and should be investigated during the development phase since it may influence the final product CQAs. The manual scooping method, although simplistic, can be a temporary solution to improve the results of API's content and uniformity when compared to industrial gravitational transfer.
Misclassification of OSA Severity With Automated Scoring of Home Sleep Recordings
Aurora, R. Nisha; Swartz, Rachel
2015-01-01
BACKGROUND: The advent of home sleep testing has allowed for the development of an ambulatory care model for OSA that most health-care providers can easily deploy. Although automated algorithms that accompany home sleep monitors can identify and classify disordered breathing events, it is unclear whether manual scoring followed by expert review of home sleep recordings is of any value. Thus, this study examined the agreement between automated and manual scoring of home sleep recordings. METHODS: Two type 3 monitors (ApneaLink Plus [ResMed] and Embletta [Embla Systems]) were examined in distinct study samples. Data from manual and automated scoring were available for 200 subjects. Two thresholds for oxygen desaturation (≥ 3% and ≥ 4%) were used to define disordered breathing events. Agreement between manual and automated scoring was examined using Pearson correlation coefficients and Bland-Altman analyses. RESULTS: Automated scoring consistently underscored disordered breathing events compared with manual scoring for both sleep monitors irrespective of whether a ≥ 3% or ≥ 4% oxygen desaturation threshold was used to define the apnea-hypopnea index (AHI). For the ApneaLink Plus monitor, Bland-Altman analyses revealed an average AHI difference between manual and automated scoring of 6.1 (95% CI, 4.9-7.3) and 4.6 (95% CI, 3.5-5.6) events/h for the ≥ 3% and ≥ 4% oxygen desaturation thresholds, respectively. Similarly for the Embletta monitor, the average difference between manual and automated scoring was 5.3 (95% CI, 3.2-7.3) and 8.4 (95% CI, 7.2-9.6) events/h, respectively. CONCLUSIONS: Although agreement between automated and manual scoring of home sleep recordings varies based on the device used, modest agreement was observed between the two approaches. However, manual review of home sleep test recordings can decrease the misclassification of OSA severity, particularly for those with mild disease. TRIAL REGISTRY: ClinicalTrials.gov; No.: NCT01503164; www.clinicaltrials.gov PMID:25411804
Hammack, Thomas S; Valentin-Bon, Iris E; Jacobson, Andrew P; Andrews, Wallace H
2004-05-01
Soak and rinse methods were compared for the recovery of Salmonella from whole cantaloupes. Cantaloupes were surface inoculated with Salmonella cell suspensions and stored for 4 days at 2 to 6 degrees C. Cantaloupes were placed in sterile plastic bags with a nonselective preenrichment broth at a 1:1.5 cantaloupe weight-to-broth volume ratio. The cantaloupe broths were shaken for 5 min at 100 rpm after which 25-ml aliquots (rinse) were removed from the bags. The 25-ml rinses were preenriched in 225-ml portions of the same uninoculated broth type at 35 degrees C for 24 h (rinse method). The remaining cantaloupe broths were incubated at 35 degrees C for 24 h (soak method). The preenrichment broths used were buffered peptone water (BPW), modified BPW, lactose (LAC) broth, and Universal Preenrichment (UP) broth. The Bacteriological Analytical Manual Salmonella culture method was compared with the following rapid methods: the TECRA Unique Salmonella method, the VIDAS ICS/SLM method, and the VIDAS SLM method. The soak method detected significantly more Salmonella-positive cantaloupes (P < 0.05) than did the rinse method: 367 Salmonella-positive cantaloupes of 540 test cantaloupes by the soak method and 24 Salmonella-positive cantaloupes of 540 test cantaloupes by the rinse method. Overall, BPW, LAC, and UP broths were equivalent for the recovery of Salmonella from cantaloupes. Both the VIDAS ICS/SLM and TECRA Unique Salmonella methods detected significantly fewer Salmonella-positive cantaloupes than did the culture method: the VIDAS ICS/SLM method detected 23 of 50 Salmonella-positive cantaloupes (60 tested) and the TECRA Unique Salmonella method detected 16 of 29 Salmonella-positive cantaloupes (60 tested). The VIDAS SLM and culture methods were equivalent: both methods detected 37 of 37 Salmonella-positive cantaloupes (60 tested).
The methods and instructions for field operations presented in this manual for surveys of non-wadeable streams and rivers were developed and tested based on 55 sample sites in the Mid-Atlantic region and 53 sites in an Oregon study during two years of pilot and demonstration proj...
Validation of a Mobile Device for Acoustic Coordinated Reset Neuromodulation Tinnitus Therapy.
Hauptmann, Christian; Wegener, Alexander; Poppe, Hendrik; Williams, Mark; Popelka, Gerald; Tass, Peter A
2016-10-01
Sound-based tinnitus intervention stimuli include broad-band noise signals with subjectively adjusted bandwidths used as maskers delivered by commercial devices or hearing aids, environmental sounds broadly described and delivered by both consumer devices and hearing aids, music recordings specifically modified and delivered in a variety of different ways, and other stimuli. Acoustic coordinated reset neuromodulation therapy for tinnitus reduction has unique and more stringent requirements compared to all other sound-based tinnitus interventions. These include precise characterization of tinnitus pitch and loudness, and effective provision of patient-controlled daily therapy signals at defined frequencies, levels, and durations outside of the clinic. The purpose of this study was to evaluate an approach to accommodate these requirements including evaluation of a mobile device, validation of an automated tinnitus pitch-matching algorithm and assessment of a patient's ability to control stimuli and collect repeated outcome measures. The experimental design involved direct laboratory measurements of the sound delivery capabilities of a mobile device, comparison of an automated, adaptive pitch-matching method to a traditional manual method and measures of a patient's ability to understand and manipulate a mobile device graphic user interface to both deliver the therapy signals and collect the outcome measures. This study consisted of 5 samples of a common mobile device for the laboratory measures and a total of 30 adult participants: 15 randomly selected normal-hearing participants with simulated tinnitus for validation of a tinnitus pitch-matching algorithm and 15 sequentially selected patients already undergoing tinnitus therapy for evaluation of patient usability. No tinnitus intervention(s) were specifically studied as a component of this study. Data collection involved laboratory measures of mobile devices, comparison of manual and automated adaptive tinnitus pitch-matching psychoacoustic procedures in the same participant analyzed for absolute differences (t test), variance differences (f test), and range comparisons, and assessment of patient usability including questionnaire measures and logs of patient observations. Mobile devices are able to reliably and accurately deliver the acoustic therapy signals. There was no difference in mean pitch matches (t test, p > 0.05) between an automated adaptive method compared to a traditional manual pitch-matching method. However, the variability of the automated pitch-matching method was much less (f test, p < 0.05) with twice as many matches within the predefined error range (±5%) compared to the manual pitch-matching method (80% versus 40%). After a short initial training, all participants were able to use the mobile device effectively and to perform the required tasks without further professional assistance. American Academy of Audiology
Li, Guo-Cai; Zhang, Yu-Chun; Xu, Yong; Zhang, Fang-Cheng; Huang, Wei-Hua; Xu, Jian-Qing; Ma, Qing-Jiu
2014-01-01
The key point of digestive cancer surgery is reconstruction and anastomosis of the digestive tract. Traditional anastomoses involve double-layer interrupted suturing, manually or using a surgical stapler. In special anatomical locations, however, suturing may become increasingly difficult and the complication rate increases accordingly. In this study, we aimed to investigate the feasibility and safety of a new manual suturing method, the single-layer continuous suture in the posterior wall of the anastomosis. Between January, 2007 and August, 2012, 101 patients with digestive cancer underwent surgery in Xi'an Gaoxin Hospital. Of those patients, 27 underwent surgery with the new manual method and the remaining 74 underwent surgery using traditional methods of anastomosis of the digestive tract. Surgical time, intraoperative blood loss, drainage duration, complications, blood tests, postoperative quality of life (QOL) and overall expenditure were recorded and analyzed. No significant differences were observed in surgical time, intraoperative blood loss, temperature, blood tests and postoperative QOL between the two groups. However, compared with the control group, the new manual suture group exhibited a lower surgical complication rate (7.40 vs. 31.08%; P=0.018), lower blood transfusion volume (274.07±419.33 vs. 646.67±1,146.06 ml; P=0.053), shorter postoperative hospital stay (14.60±4.19 vs. 17.60±6.29 days; P=0.038) and lower overall expenditure (3,509.85±768.68 vs. 6,141.83±308.90 renminbi; P=0.001). Our results suggested that single-layer continuous suturing for the anastomosis of the digestive tract is feasible and safe and may contribute to the reduction of surgical complications and overall expenditure.
LI, GUO-CAI; ZHANG, YU-CHUN; XU, YONG; ZHANG, FANG-CHENG; HUANG, WEI-HUA; XU, JIAN-QING; MA, QING-JIU
2014-01-01
The key point of digestive cancer surgery is reconstruction and anastomosis of the digestive tract. Traditional anastomoses involve double-layer interrupted suturing, manually or using a surgical stapler. In special anatomical locations, however, suturing may become increasingly difficult and the complication rate increases accordingly. In this study, we aimed to investigate the feasibility and safety of a new manual suturing method, the single-layer continuous suture in the posterior wall of the anastomosis. Between January, 2007 and August, 2012, 101 patients with digestive cancer underwent surgery in Xi’an Gaoxin Hospital. Of those patients, 27 underwent surgery with the new manual method and the remaining 74 underwent surgery using traditional methods of anastomosis of the digestive tract. Surgical time, intraoperative blood loss, drainage duration, complications, blood tests, postoperative quality of life (QOL) and overall expenditure were recorded and analyzed. No significant differences were observed in surgical time, intraoperative blood loss, temperature, blood tests and postoperative QOL between the two groups. However, compared with the control group, the new manual suture group exhibited a lower surgical complication rate (7.40 vs. 31.08%; P=0.018), lower blood transfusion volume (274.07±419.33 vs. 646.67±1,146.06 ml; P=0.053), shorter postoperative hospital stay (14.60±4.19 vs. 17.60±6.29 days; P=0.038) and lower overall expenditure (3,509.85±768.68 vs. 6,141.83±308.90 renminbi; P=0.001). Our results suggested that single-layer continuous suturing for the anastomosis of the digestive tract is feasible and safe and may contribute to the reduction of surgical complications and overall expenditure. PMID:24649327
ERIC Educational Resources Information Center
Bryden, P.J.; Roy, E.A.
2005-01-01
The purpose of the present study was twofold: first to examine the influences of sex and handedness on manual performance on the Grooved Pegboard Test; and secondly to provide normative data for two versions (Place and Remove tasks) of the Grooved Pegboard Test, as previous work (Bryden & Roy, 1999) had suggested that the Remove task of the…
Methicillin-resistant Staphylococcus aureus: an overview for manual therapists().
Green, Bart N; Johnson, Claire D; Egan, Jonathon Todd; Rosenthal, Michael; Griffith, Erin A; Evans, Marion Willard
2012-03-01
Methicillin-resistant Staphylococcus aureus (MRSA) is associated with difficult-to-treat infections and high levels of morbidity. Manual practitioners work in environments where MRSA is a common acquired infection. The purpose of this review is to provide a practical overview of MRSA as it applies to the manual therapy professions (eg, physical and occupational therapy, athletic training, chiropractic, osteopathy, massage, sports medicine) and to discuss how to identify and prevent MRSA infections in manual therapy work environments. PubMed and CINAHL were searched from the beginning of their respective indexing years through June 2011 using the search terms MRSA, methicillin-resistant Staphylococcus aureus, and Staphylococcus aureus. Texts and authoritative Web sites were also reviewed. Pertinent articles from the authors' libraries were included if they were not already identified in the literature search. Articles were included if they were applicable to ambulatory health care environments in which manual therapists work or if the content of the article related to the clinical management of MRSA. Following information extraction, 95 citations were included in this review, to include 76 peer-reviewed journal articles, 16 government Web sites, and 3 textbooks. Information was organized into 10 clinically relevant categories for presentation. Information was organized into the following clinically relevant categories: microbiology, development of MRSA, risk factors for infection, clinical presentation, diagnostic tests, screening tests, reporting, treatment, prevention for patients and athletes, and prevention for health care workers. Methicillin-resistant S aureus is a health risk in the community and to patients and athletes treated by manual therapists. Manual practitioners can play an essential role in recognizing MRSA infections and helping to control its transmission in the health care environment and the community. Essential methods for protecting patients and health care workers include being aware of presenting signs, patient education, and using appropriate hand and clinic hygiene.
Graph theoretical stable allocation as a tool for reproduction of control by human operators
NASA Astrophysics Data System (ADS)
van Nooijen, Ronald; Ertsen, Maurits; Kolechkina, Alla
2016-04-01
During the design of central control algorithms for existing water resource systems under manual control it is important to consider the interaction with parts of the system that remain under manual control and to compare the proposed new system with the existing manual methods. In graph theory the "stable allocation" problem has good solution algorithms and allows for formulation of flow distribution problems in terms of priorities. As a test case for the use of this approach we used the algorithm to derive water allocation rules for the Gezira Scheme, an irrigation system located between the Blue and White Niles south of Khartoum. In 1925, Gezira started with 300,000 acres; currently it covers close to two million acres.
Federal Register 2010, 2011, 2012, 2013, 2014
2013-04-16
... System Test Laboratories Program Manual, Version 2.0 AGENCY: United States Election Assistance Commission (EAC). ACTION: Notice; publication of Voting System Test Laboratories Program Manual, Version 2.0, for 60 day public comment period on EAC Web site. SUMMARY: The U.S. Election Assistance Commission (EAC...
SPSS and SAS programming for the testing of mediation models.
Dudley, William N; Benuzillo, Jose G; Carrico, Mineh S
2004-01-01
Mediation modeling can explain the nature of the relation among three or more variables. In addition, it can be used to show how a variable mediates the relation between levels of intervention and outcome. The Sobel test, developed in 1990, provides a statistical method for determining the influence of a mediator on an intervention or outcome. Although interactive Web-based and stand-alone methods exist for computing the Sobel test, SPSS and SAS programs that automatically run the required regression analyses and computations increase the accessibility of mediation modeling to nursing researchers. To illustrate the utility of the Sobel test and to make this programming available to the Nursing Research audience in both SAS and SPSS. The history, logic, and technical aspects of mediation testing are introduced. The syntax files sobel.sps and sobel.sas, created to automate the computation of the regression analysis and test statistic, are available from the corresponding author. The reported programming allows the user to complete mediation testing with the user's own data in a single-step fashion. A technical manual included with the programming provides instruction on program use and interpretation of the output. Mediation modeling is a useful tool for describing the relation between three or more variables. Programming and manuals for using this model are made available.
Novas, Romulo Bourget; Fazan, Valeria Paula Sassoli; Felipe, Joaquim Cezar
2016-02-01
Nerve morphometry is known to produce relevant information for the evaluation of several phenomena, such as nerve repair, regeneration, implant, transplant, aging, and different human neuropathies. Manual morphometry is laborious, tedious, time consuming, and subject to many sources of error. Therefore, in this paper, we propose a new method for the automated morphometry of myelinated fibers in cross-section light microscopy images. Images from the recurrent laryngeal nerve of adult rats and the vestibulocochlear nerve of adult guinea pigs were used herein. The proposed pipeline for fiber segmentation is based on the techniques of competitive clustering and concavity analysis. The evaluation of the proposed method for segmentation of images was done by comparing the automatic segmentation with the manual segmentation. To further evaluate the proposed method considering morphometric features extracted from the segmented images, the distributions of these features were tested for statistical significant difference. The method achieved a high overall sensitivity and very low false-positive rates per image. We detect no statistical difference between the distribution of the features extracted from the manual and the pipeline segmentations. The method presented a good overall performance, showing widespread potential in experimental and clinical settings allowing large-scale image analysis and, thus, leading to more reliable results.
Onboard Classifiers for Science Event Detection on a Remote Sensing Spacecraft
NASA Technical Reports Server (NTRS)
Castano, Rebecca; Mazzoni, Dominic; Tang, Nghia; Greeley, Ron; Doggett, Thomas; Cichy, Ben; Chien, Steve; Davies, Ashley
2006-01-01
Typically, data collected by a spacecraft is downlinked to Earth and pre-processed before any analysis is performed. We have developed classifiers that can be used onboard a spacecraft to identify high priority data for downlink to Earth, providing a method for maximizing the use of a potentially bandwidth limited downlink channel. Onboard analysis can also enable rapid reaction to dynamic events, such as flooding, volcanic eruptions or sea ice break-up. Four classifiers were developed to identify cryosphere events using hyperspectral images. These classifiers include a manually constructed classifier, a Support Vector Machine (SVM), a Decision Tree and a classifier derived by searching over combinations of thresholded band ratios. Each of the classifiers was designed to run in the computationally constrained operating environment of the spacecraft. A set of scenes was hand-labeled to provide training and testing data. Performance results on the test data indicate that the SVM and manual classifiers outperformed the Decision Tree and band-ratio classifiers with the SVM yielding slightly better classifications than the manual classifier.
One Small Step for Manuals: Computer-Assisted Training in Twelve-Step Facilitation*
Sholomskas, Diane E.; Carroll, Kathleen M.
2008-01-01
Objective The burgeoning number of empirically validated therapies has not been met with systematic evaluation of practical, inexpensive means of teaching large numbers of clinicians to use these treatments effectively. An interactive, computer-assisted training program that sought to impart skills associated with the Project MATCH (Matching Alcoholism Treatments to Client Heterogeneity) Twelve-Step Facilitation (TSF) manual was developed to address this need. Method Twenty-five community-based substance use-treatment clinicians were randomized to one of two training conditions: (1) access to the computer-assisted training program plus the TSF manual or (2) access to the manual only. The primary outcome measure was change from pre- to posttraining in the clinicians' ability to demonstrate key TSF skills. Results The data suggested that the clinicians' ability to implement TSF, as assessed by independent ratings of adherence and skill for the key TSF interventions, was significantly higher after training for those who had access to the computerized training condition than those who were assigned to the manual-only condition. Those assigned to the computer-assisted training condition also demonstrated greater gains in a knowledge test assessing familiarity with concepts presented in the TSF manual. Conclusions Computer-based training may be a feasible and effective means of training larger numbers of clinicians in empirically supported, manual-guided therapies. PMID:17061013
Fisher, Beth E; Davenport, Todd E; Kulig, Kornelia; Wu, Allan D
2009-01-01
Background Many health care practitioners use a variety of hands-on treatments to improve symptoms and disablement in patients with musculoskeletal pathology. Research to date indirectly suggests a potentially broad effect of manual therapy on the neuromotor processing of functional behavior within the supraspinal central nervous system (CNS) in a manner that may be independent of modification at the level of local spinal circuits. However, the effect of treatment speed, as well as the specific mechanism and locus of CNS changes, remain unclear. Methods/Design We developed a placebo-controlled, randomized study to test the hypothesis that manual therapy procedures directed to the talocrural joint in individuals with post-acute ankle sprain induce a change in corticospinal excitability that is relevant to improve the performance of lower extremity functional behavior. Discussion This study is designed to identify potential neuromotor changes associated with manual therapy procedures directed to the appendicular skeleton, compare the relative effect of treatment speed on potential neuromotor effects of manual therapy procedures, and determine the behavioral relevance of potential neuromotor effects of manual therapy procedures. Trial Registration identifier NCT00847769. PMID:19460169
Development of a Facility Management and Improvement Manual for Army Service Schools.
1983-03-01
Ehhhhomhmhhhhlo EEEEEEEohhhhhI L-Ii Ilk . ~MICROCOPY RESOLUTION TEST CHART NATIONAL BURESU Of STA OSN-T63-A NA01BRA FSADRS16- construction m*nilhlli 8mbtg 10b...U.S. Army Construction Engineering Research Lab. P.O. Box 4005 • 4A762731AT41-A-001 Champaign, IL 61820 _ It. CONTROLLING OFFICtNAME AND ADDRESS 37...developing a data collection and analysis method. The prototype method was discussed in CERL Interim Report P-ill. 3 This prototype method was tested by
Cleaning of Root Canal System by Different Irrigation Methods.
Tanomaru-Filho, Mário; Miano, Lucas Martinati; Chávez-Andrade, Gisselle Moraima; Torres, Fernanda Ferrari Esteves; Leonardo, Renato de Toledo; Guerreiro-Tanomaru, Juliane Maria
2015-11-01
The aim of this study was to compare the cleaning of main and lateral canals using the irrigation methods: negative pressure irrigation (EndoVac system), passive ultrasonic irrigation (PUI) and manual irrigation (MI). Resin teeth were used. After root canal preparation, four lateral canals were made at 2 and 7 mm from the apex. Root canals were filled with contrast solution and radiographed pre- and post-irrigation using digital radiographic system [radiovisiography (RVG)]. The irrigation protocols were: MI1-manual irrigation [22 G needle at 5 mm short of working length-WL]; MI2-manual irrigation (30G needle at 2 mm short of WL); PUI; EV1-EndoVac (microcannula at 1 mm short of WL); EV2-Endovac (microcannula at 3 mm short of WL). The obtained images, initial (filled with contrast solution) and final (after irrigation) were analyzed by using image tool 3.0 software. Statistical analysis was performed by analysis of variance (ANOVA) and Tukey tests (5% significance level). EV1 and EV2, followed by PUI showed better cleaning capacity than manual irrigation (MI1 and MI2) (p < 0.05). Negative pressure irrigation and PUI promoted better cleaning of main and simulated lateral canals. Conventional manual irrigation technique may promote less root canal cleaning in the apical third. For this reason, the search for other irrigation protocols is important, and EndoVac and PUI are alternatives to contribute to irrigation effectiveness.
USDA-ARS?s Scientific Manuscript database
This book chapter for the 8th edition of the OIE Manual of Diagnostic Tests and Vaccines for Terrestrial Animals describes the current state of knowledge regarding progressive atrophic rhinitis of swine. Topics covered include clinical signs and lesions, characteristics and methods of detection for...
Optimization of Fit for Mass Customized Apparel Ordering Using Fit Preference and Self Measurement.
2000-01-01
shorts had the highest satisfaction of fit and which short provided the optimum fit. Finally a discrepancy question form and a manual order form were...used during fit test sessions. In pilot testing manual order forms were used exclusively to record self-measurements and fit preference responses for...test participants. The website requirements were completed on site in the pilot test and manual order forms were returned to test evaluators once
Comparison of Cobas 6500 and Iris IQ200 fully-automated urine analyzers to manual urine microscopy
Bakan, Ebubekir; Ozturk, Nurinnisa; Baygutalp, Nurcan Kilic; Polat, Elif; Akpinar, Kadriye; Dorman, Emrullah; Polat, Harun; Bakan, Nuri
2016-01-01
Introduction Urine screening is achieved by either automated or manual microscopic analysis. The aim of the study was to compare Cobas 6500 and Iris IQ200 urine analyzers, and manual urine microscopic analysis. Materials and methods A total of 540 urine samples sent to the laboratory for chemical and sediment analysis were analyzed on Cobas 6500 and Iris IQ200 within 1 hour from sampling. One hundred and fifty three samples were found to have pathological sediment results and were subjected to manual microscopic analysis performed by laboratory staff blinded to the study. Spearman’s and Gamma statistics were used for correlation analyses, and the McNemar test for the comparison of the two automated analyzers. Results The comparison of Cobas u701 to the manual method yielded the following regression equations: y = - 0.12 (95% CI: - 1.09 to 0.67) + 0.78 (95% CI: 0.65 to 0.95) x for WBC and y = 0.06 (95% CI: - 0.09 to 0.25) + 0.66 (95% CI: 0.57 to 0.73) x for RBC. The comparison of IQ200 Elite to manual method the following equations: y = 0.03 (95% CI: - 1.00 to 1.00) + 0.88 (95% CI: 0.66 to 1.00) x for WBC and y = - 0.22 (95% CI: - 0.80 to 0.20) + 0.40 (95% CI: 0.32 to 0.50) x for RBC. IQ200 Elite compared to Cobas u701 yielded the following equations: y = - 0.95 (95% CI: - 2.13 to 0.11) + 1.25 (95% CI: 1.08 to 1.44) x for WBC and y = - 1.20 (95% CI: - 1.80 to -0.30) + 0. 80 (95% CI: 0.55 to 1.00) x for RBC. Conclusions The two analyzers showed similar performances and good compatibility to manual microscopy. However, they are still inadequate in the determination of WBC, RBC, and EC in highly-pathological samples. Thus, confirmation by manual microscopic analysis may be useful. PMID:27812305
ERIC Educational Resources Information Center
Anderson, Paul S.
Initial experiences with computer-assisted reconsiderative scoring are described. Reconsiderative scoring occurs when student responses are received and reviewed by the teacher before points for correctness are assigned. Manually scored completion-style questions are reconsiderative. A new method of machine assistance produces an item analysis on…
Automatic measurement of voice onset time using discriminative structured prediction.
Sonderegger, Morgan; Keshet, Joseph
2012-12-01
A discriminative large-margin algorithm for automatic measurement of voice onset time (VOT) is described, considered as a case of predicting structured output from speech. Manually labeled data are used to train a function that takes as input a speech segment of an arbitrary length containing a voiceless stop, and outputs its VOT. The function is explicitly trained to minimize the difference between predicted and manually measured VOT; it operates on a set of acoustic feature functions designed based on spectral and temporal cues used by human VOT annotators. The algorithm is applied to initial voiceless stops from four corpora, representing different types of speech. Using several evaluation methods, the algorithm's performance is near human intertranscriber reliability, and compares favorably with previous work. Furthermore, the algorithm's performance is minimally affected by training and testing on different corpora, and remains essentially constant as the amount of training data is reduced to 50-250 manually labeled examples, demonstrating the method's practical applicability to new datasets.
NASA Astrophysics Data System (ADS)
Taboada, B.; Vega-Alvarado, L.; Córdova-Aguilar, M. S.; Galindo, E.; Corkidi, G.
2006-09-01
Characterization of multiphase systems occurring in fermentation processes is a time-consuming and tedious process when manual methods are used. This work describes a new semi-automatic methodology for the on-line assessment of diameters of oil drops and air bubbles occurring in a complex simulated fermentation broth. High-quality digital images were obtained from the interior of a mechanically stirred tank. These images were pre-processed to find segments of edges belonging to the objects of interest. The contours of air bubbles and oil drops were then reconstructed using an improved Hough transform algorithm which was tested in two, three and four-phase simulated fermentation model systems. The results were compared against those obtained manually by a trained observer, showing no significant statistical differences. The method was able to reduce the total processing time for the measurements of bubbles and drops in different systems by 21-50% and the manual intervention time for the segmentation procedure by 80-100%.
NASA Astrophysics Data System (ADS)
Fussi, F. Fabio; Fumagalli, Letizia; Fava, Francesco; Di Mauro, Biagio; Kane, Cheik Hamidou; Niang, Magatte; Wade, Souleye; Hamidou, Barry; Colombo, Roberto; Bonomi, Tullia
2017-12-01
A method is proposed that uses analysis of borehole stratigraphic logs for the characterization of shallow aquifers and for the assessment of areas suitable for manual drilling. The model is based on available borehole-log parameters: depth to hard rock, depth to water, thickness of laterite and hydraulic transmissivity of the shallow aquifer. The model is applied to a study area in northwestern Senegal. A dataset of boreholes logs has been processed using a software package (TANGAFRIC) developed during the research. After a manual procedure to assign a standard category describing the lithological characteristics, the next step is the automated extraction of different textural parameters and the estimation of hydraulic conductivity using reference values available in the literature. The hydraulic conductivity values estimated from stratigraphic data have been partially validated, by comparing them with measured values from a series of pumping tests carried out in large-diameter wells. The results show that this method is able to produce a reliable interpretation of the shallow hydrogeological context using information generally available in the region. The research contributes to improving the identification of areas where conditions are suitable for manual drilling. This is achieved by applying the described method, based on a structured and semi-quantitative approach, to classify the zones of suitability for given manual drilling techniques using data available in most African countries. Ultimately, this work will support proposed international programs aimed at promoting low-cost water supply in Africa and enhancing access to safe drinking water for the population.
Kwak, Jihoon; Genovesio, Auguste; Kang, Myungjoo; Hansen, Michael Adsett Edberg; Han, Sung-Jun
2015-01-01
Genotoxicity testing is an important component of toxicity assessment. As illustrated by the European registration, evaluation, authorization, and restriction of chemicals (REACH) directive, it concerns all the chemicals used in industry. The commonly used in vivo mammalian tests appear to be ill adapted to tackle the large compound sets involved, due to throughput, cost, and ethical issues. The somatic mutation and recombination test (SMART) represents a more scalable alternative, since it uses Drosophila, which develops faster and requires less infrastructure. Despite these advantages, the manual scoring of the hairs on Drosophila wings required for the SMART limits its usage. To overcome this limitation, we have developed an automated SMART readout. It consists of automated imaging, followed by an image analysis pipeline that measures individual wing genotoxicity scores. Finally, we have developed a wing score-based dose-dependency approach that can provide genotoxicity profiles. We have validated our method using 6 compounds, obtaining profiles almost identical to those obtained from manual measures, even for low-genotoxicity compounds such as urethane. The automated SMART, with its faster and more reliable readout, fulfills the need for a high-throughput in vivo test. The flexible imaging strategy we describe and the analysis tools we provide should facilitate the optimization and dissemination of our methods. PMID:25830368
Validity of radiographic assessment of the knee joint space using automatic image analysis.
Komatsu, Daigo; Hasegawa, Yukiharu; Kojima, Toshihisa; Seki, Taisuke; Ikeuchi, Kazuma; Takegami, Yasuhiko; Amano, Takafumi; Higuchi, Yoshitoshi; Kasai, Takehiro; Ishiguro, Naoki
2016-09-01
The present study investigated whether there were differences between automatic and manual measurements of the minimum joint space width (mJSW) on knee radiographs. Knee radiographs of 324 participants in a systematic health screening were analyzed using the following three methods: manual measurement of film-based radiographs (Manual), manual measurement of digitized radiographs (Digital), and automatic measurement of digitized radiographs (Auto). The mean mJSWs on the medial and lateral sides of the knees were determined using each method, and measurement reliability was evaluated using intra-class correlation coefficients. Measurement errors were compared between normal knees and knees with radiographic osteoarthritis. All three methods demonstrated good reliability, although the reliability was slightly lower with the Manual method than with the other methods. On the medial and lateral sides of the knees, the mJSWs were the largest in the Manual method and the smallest in the Auto method. The measurement errors of each method were significantly larger for normal knees than for radiographic osteoarthritis knees. The mJSW measurements are more accurate and reliable with the Auto method than with the Manual or Digital method, especially for normal knees. Therefore, the Auto method is ideal for the assessment of the knee joint space.
Verhaeghe, C; Parot-Schinkel, E; Bouet, P E; Madzou, S; Biquard, F; Gillard, P; Descamps, P; Legendre, G
2018-02-14
The frequency of posterior presentations (occiput of the fetus towards the sacrum of the mother) in labor is approximately 20% and, of this, 5% remain posterior until the end of labor. These posterior presentations are associated with higher rates of cesarean section and instrumental delivery. Manual rotation of a posterior position in order to rotate the fetus to an anterior position has been proposed in order to reduce the rate of instrumental fetal delivery. No randomized study has compared the efficacy of this procedure to expectant management. We therefore propose a monocentric, interventional, randomized, prospective study to show the superiority of vaginal delivery rates using the manual rotation of the posterior position at full dilation over expectant management. Ultrasound imaging of the presentation will be performed at full dilation on all the singleton pregnancies for which a clinical suspicion of a posterior position was raised at more than 37 weeks' gestation (WG). In the event of an ultrasound confirming a posterior position, the patient will be randomized into an experimental group (manual rotation) or a control group (expectative management with no rotation). For a power of 90% and the hypothesis that vaginal deliveries will increase by 20%, (10% of patients lost to follow-up) 238 patients will need to be included in the study. The primary endpoint will be the rate of spontaneous vaginal deliveries (expected rate without rotation: 60%). The secondary endpoints will be the rate of fetal extractions (cesarean or instrumental) and the maternal and fetal morbidity and mortality rates. The intent-to-treat study will be conducted over 24 months. Recruitment started in February 2017. To achieve the primary objective, we will perform a test comparing the number of spontaneous vaginal deliveries in the two groups using Pearson's chi-squared test (provided that the conditions for using this test are satisfactory in terms of numbers). In the event that this test cannot be performed, we will use Fisher's exact test. Given that the efficacy of manual rotation has not been proven with a high level of evidence, the practice of this technique is not systematically recommended by scholarly societies and is, therefore, rarely performed by obstetric gynecologists. If our hypothesis regarding the superiority of manual rotation is confirmed, our study will help change delivery practices in cases of posterior fetal position. An increase in the rates of vaginal delivery will help decrease the short- and long-term rates of morbidity and mortality following cesarean section. Manual rotation is a simple and effective method with a success rate of almost 90%. Several preliminary studies have shown that manual rotation is associated with reduced rates for fetal extraction and maternal complications: Shaffer has shown that the cesarean section rate is lower in patients for whom a manual rotation is performed successfully (2%) with a 9% rate of cesarean sections when manual rotation is performed versus 41% when it is not performed. Le Ray has shown that manual rotation significantly reduces vaginal delivery rates via fetal extraction (23.2% vs 38.7%, p < 0.01). However, manual rotation is not systematically performed due to the absence of proof of its efficacy in retrospective studies and quasi-experimental before/after studies. ClinicalTrials.gov, Identifier: NCT03009435 . Registered on 30 December 2016.
Wong, M S; Cheng, J C Y; Wong, M W; So, S F
2005-04-01
A study was conducted to compare the CAD/CAM method with the conventional manual method in fabrication of spinal orthoses for patients with adolescent idiopathic scoliosis. Ten subjects were recruited for this study. Efficiency analyses of the two methods were performed from cast filling/ digitization process to completion of cast/image rectification. The dimensional changes of the casts/ models rectified by the two cast rectification methods were also investigated. The results demonstrated that the CAD/CAM method was faster than the conventional manual method in the studied processes. The mean rectification time of the CAD/CAM method was shorter than that of the conventional manual method by 108.3 min (63.5%). This indicated that the CAD/CAM method took about 1/3 of the time of the conventional manual to finish cast rectification. In the comparison of cast/image dimensional differences between the conventional manual method and the CAD/CAM method, five major dimensions in each of the five rectified regions namely the axilla, thoracic, lumbar, abdominal and pelvic regions were involved. There were no significant dimensional differences (p < 0.05) in 19 out of the 25 studied dimensions. This study demonstrated that the CAD/CAM system could save the time in the rectification process and offer a relatively high resemblance in cast rectification as compared with the conventional manual method.
Wiggen, Øystein Nordrum; Heen, Sigri; Færevik, Hilde; Reinertsen, Randi Eidsmo
2011-01-01
The purpose of this study was to investigate manual performance and thermal responses during low work intensity in persons wearing standard protective clothing in the petroleum industry when they were exposed to a range of temperatures (5, -5, -15 and -25℃) that are relevant to environmental conditions for petroleum industry personnel in northern regions. Twelve men participated in the study. Protective clothing was adjusted for the given cold exposure according to current practices. The subjects performed manual tests five times under each environmental condition. The manual performance test battery consisted of four different tests: tactile sensation (Semmes-Weinstein monofilaments), finger dexterity (Purdue Pegboard), hand dexterity (Complete Minnesota dexterity test) and grip strength (grip dynamometer). We found that exposure to -5℃ or colder lowered skin and body temperatures and reduced manual performance during low work intensity. In conclusion the current protective clothing at a given cold exposure is not adequate to maintain manual performance and thermal balance for petroleum workers in the high north.
Computerized Adaptive Testing (CAT): A User Manual
1984-03-12
NPRDC TR 84-32 COMPUTERIZED ADAPTIVE TESTING ( CAT ): A USER MANUAL Susan Hardwick Lawrence Eastman Ross Cooper Rehab Group, Incorporated San...a ~EI’IOD COVIRED COMPUTERIZED ADAPTIVE TESTING ( CAT ) Final Report Aug 1981-June 1982 A USER MANUAL 1. ~l:l’t,ORMINCI ORCI. RE~ORT NUM.I:R 62-83...II nee• .. _, entl ldentll)’ ,,. llloclr _,.,) A joint-service effort is underway to develop a computerized adaptive testing ( CAT ) system and to
Fatigue Lives Of Laser-Cut Metals
NASA Technical Reports Server (NTRS)
Martin, Michael R.
1988-01-01
Fatigue lives made to approach those attainable by traditional grinding methods. Fatigue-test specimens prepared from four metallic alloys, and material removed from specimens by manual grinding, by Nd:glass laser, and by Nd:YAG laser. Results of fatigue tests of all specimens indicated reduction of fatigue strengths of laser-fired specimens. Laser machining holds promise for improved balancing of components of gas turbines.
Wong, M S; Cheng, J C Y; Lo, K H
2005-04-01
The treatment effectiveness of the CAD/CAM method and the manual method in managing adolescent idiopathic scoliosis (AIS) was compared. Forty subjects were recruited with twenty subjects for each method. The clinical parameters namely Cobb's angle and apical vertebral rotation were evaluated at the pre-brace and the immediate in-brace visits. The results demonstrated that orthotic treatments rendered by the CAD/CAM method and the conventional manual method were effective in providing initial control of Cobb's angle. Significant decreases (p < 0.05) were found between the pre-brace and immediate in-brace visits for both methods. The mean reductions of Cobb's angle were 12.8 degrees (41.9%) for the CAD/CAM method and 9.8 degrees (32.1%) for the manual method. An initial control of the apical vertebral rotation was not shown in this study. In the comparison between the CAD/CAM method and the manual method, no significant difference was found in the control of Cobb's angle and apical vertebral rotation. The current study demonstrated that the CAD/CAM method can provide similar result in the initial stage of treatment as compared with the manual method.
Sethi, Saurabh; Huang, Robert J.; Barakat, Monique T.; Banaei, Niaz; Friedland, Shai; Banerjee, Subhas
2017-01-01
Background/Aims Recent outbreaks of duodenoscope-transmitted infections underscore the importance of adequate endoscope reprocessing. Adenosine triphosphate (ATP) bioluminescence testing allows rapid evaluation of endoscopes for bacteriological/biological residue. In this prospective study we evaluate the utility of ATP in bacteriological surveillance, and the effects of endoscopy staff education and dual cycles of cleaning and high-level disinfection (HLD) on endoscope reprocessing. Methods ATP bioluminescence was measured after pre-cleaning, manual cleaning and HLD on rinsates from suction-biopsy channels of all endoscopes and elevator channels of duodenoscopes/linear echoendoscopes after use. ATP bioluminescence was re-measured in duodenoscopes (1) after re-education and competency testing of endoscopy staff, and subsequently (2) after 2 cycles of pre-cleaning and manual cleaning and single cycle of HLD, or (3) after 2 cycles of pre-cleaning, manual cleaning and HLD. Results The ideal ATP bioluminescence benchmark of <200 relative light units (RLUs) after manual cleaning was achieved from suction-biopsy channel rinsates of all endoscopes, but 9 of 10 duodenoscope elevator channel rinsates failed to meet this benchmark. Re-education reduced RLUs in duodenoscope elevator channel rinsates after pre-cleaning (23218.0 vs 1340.5 RLUs, p<0.01) and HLD (177.0 vs 12.0 RLUs, p<0.01). After 2 cycles of manual cleaning/HLD, duodenoscope elevator channel RLUs achieved levels similar to sterile water, with corresponding negative cultures. Conclusions ATP testing offers a rapid, inexpensive alternative for detection of endoscope microbial residue. Re-education of endoscopy staff and 2 cycles of cleaning and HLD decrease elevator channel RLUs to levels similar to sterile water and may therefore minimize the risk of transmission of infections by duodenoscopes. PMID:27818222
Sun, Jennifer K; Qin, Haijing; Aiello, Lloyd Paul; Melia, Michele; Beck, Roy W; Andreoli, Christopher M; Edwards, Paul A; Glassman, Adam R; Pavlica, Michael R
2012-04-01
To compare visual acuity (VA) scores after autorefraction vs manual refraction in eyes of patients with diabetes mellitus and a wide range of VAs. The letter score from the Electronic Visual Acuity (EVA) test from the electronic Early Treatment Diabetic Retinopathy Study was measured after autorefraction (AR-EVA score) and after manual refraction (MR-EVA score), which is the research protocol of the Diabetic Retinopathy Clinical Research Network. Testing order was randomized, study participants and VA examiners were masked to refraction source, and a second EVA test using an identical supplemental manual refraction (MR-EVAsuppl score) was performed to determine test-retest variability. In 878 eyes of 456 study participants, the median MR-EVA score was 74 (Snellen equivalent, approximately 20/32). The spherical equivalent was often similar for manual refraction and autorefraction (median difference, 0.00; 5th-95th percentile range, -1.75 to 1.13 diopters). However, on average, the MR-EVA scores were slightly better than the AR-EVA scores, across the entire VA range. Furthermore, the variability between the AR-EVA scores and the MR-EVA scores was substantially greater than the test-retest variability of the MR-EVA scores (P < .001). The variability of differences was highly dependent on the autorefractor model. Across a wide range of VAs at multiple sites using a variety of autorefractors, VA measurements tend to be worse with autorefraction than manual refraction. Differences between individual autorefractor models were identified. However, even among autorefractor models that compare most favorably with manual refraction, VA variability between autorefraction and manual refraction is higher than the test-retest variability of manual refraction. The results suggest that, with current instruments, autorefraction is not an acceptable substitute for manual refraction for most clinical trials with primary outcomes dependent on best-corrected VA.
A Tool for Requirements-Based Programming
NASA Technical Reports Server (NTRS)
Rash, James L.; Hinchey, Michael G.; Rouff, Christopher A.; Gracanin, Denis; Erickson, John
2005-01-01
Absent a general method for mathematically sound, automated transformation of customer requirements into a formal model of the desired system, developers must resort to either manual application of formal methods or to system testing (either manual or automated). While formal methods have afforded numerous successes, they present serious issues, e.g., costs to gear up to apply them (time, expensive staff), and scalability and reproducibility when standards in the field are not settled. The testing path cannot be walked to the ultimate goal, because exhaustive testing is infeasible for all but trivial systems. So system verification remains problematic. System or requirements validation is similarly problematic. The alternatives available today depend on either having a formal model or pursuing enough testing to enable the customer to be certain that system behavior meets requirements. The testing alternative for non-trivial systems always have some system behaviors unconfirmed and therefore is not the answer. To ensure that a formal model is equivalent to the customer s requirements necessitates that the customer somehow fully understands the formal model, which is not realistic. The predominant view that provably correct system development depends on having a formal model of the system leads to a desire for a mathematically sound method to automate the transformation of customer requirements into a formal model. Such a method, an augmentation of requirements-based programming, will be briefly described in this paper, and a prototype tool to support it will be described. The method and tool enable both requirements validation and system verification for the class of systems whose behavior can be described as scenarios. An application of the tool to a prototype automated ground control system for NASA mission is presented.
An Ultrasonographic Periodontal Probe
NASA Astrophysics Data System (ADS)
Bertoncini, C. A.; Hinders, M. K.
2010-02-01
Periodontal disease, commonly known as gum disease, affects millions of people. The current method of detecting periodontal pocket depth is painful, invasive, and inaccurate. As an alternative to manual probing, an ultrasonographic periodontal probe is being developed to use ultrasound echo waveforms to measure periodontal pocket depth, which is the main measure of periodontal disease. Wavelet transforms and pattern classification techniques are implemented in artificial intelligence routines that can automatically detect pocket depth. The main pattern classification technique used here, called a binary classification algorithm, compares test objects with only two possible pocket depth measurements at a time and relies on dimensionality reduction for the final determination. This method correctly identifies up to 90% of the ultrasonographic probe measurements within the manual probe's tolerance.
Time series modeling of human operator dynamics in manual control tasks
NASA Technical Reports Server (NTRS)
Biezad, D. J.; Schmidt, D. K.
1984-01-01
A time-series technique is presented for identifying the dynamic characteristics of the human operator in manual control tasks from relatively short records of experimental data. Control of system excitation signals used in the identification is not required. The approach is a multi-channel identification technique for modeling multi-input/multi-output situations. The method presented includes statistical tests for validity, is designed for digital computation, and yields estimates for the frequency responses of the human operator. A comprehensive relative power analysis may also be performed for validated models. This method is applied to several sets of experimental data; the results are discussed and shown to compare favorably with previous research findings. New results are also presented for a multi-input task that has not been previously modeled to demonstrate the strengths of the method.
Time Series Modeling of Human Operator Dynamics in Manual Control Tasks
NASA Technical Reports Server (NTRS)
Biezad, D. J.; Schmidt, D. K.
1984-01-01
A time-series technique is presented for identifying the dynamic characteristics of the human operator in manual control tasks from relatively short records of experimental data. Control of system excitation signals used in the identification is not required. The approach is a multi-channel identification technique for modeling multi-input/multi-output situations. The method presented includes statistical tests for validity, is designed for digital computation, and yields estimates for the frequency response of the human operator. A comprehensive relative power analysis may also be performed for validated models. This method is applied to several sets of experimental data; the results are discussed and shown to compare favorably with previous research findings. New results are also presented for a multi-input task that was previously modeled to demonstrate the strengths of the method.
La Delfa, Nicholas J; Potvin, Jim R
2017-03-01
This paper describes the development of a novel method (termed the 'Arm Force Field' or 'AFF') to predict manual arm strength (MAS) for a wide range of body orientations, hand locations and any force direction. This method used an artificial neural network (ANN) to predict the effects of hand location and force direction on MAS, and included a method to estimate the contribution of the arm's weight to the predicted strength. The AFF method predicted the MAS values very well (r 2 = 0.97, RMSD = 5.2 N, n = 456) and maintained good generalizability with external test data (r 2 = 0.842, RMSD = 13.1 N, n = 80). The AFF can be readily integrated within any DHM ergonomics software, and appears to be a more robust, reliable and valid method of estimating the strength capabilities of the arm, when compared to current approaches. Copyright © 2016 Elsevier Ltd. All rights reserved.
Manual for Scoring the Test of Directed Imagination.
ERIC Educational Resources Information Center
Veldman, Donald J.; And Others
A scoring manual for the Directed Imagination Test, a projective technique wherein the subject is instructed to write four fictional stories (four minutes are allowed for each) about teachers and their experiences, is presented. The manual provides detailed instructions for rating each story by fifteen dimensions relevant to teacher education…
NASA Technical Reports Server (NTRS)
Saltsman, James F.
1992-01-01
This manual presents computer programs for characterizing and predicting fatigue and creep-fatigue resistance of metallic materials in the high-temperature, long-life regime for isothermal and nonisothermal fatigue. The programs use the total strain version of Strainrange Partitioning (TS-SRP). An extensive database has also been developed in a parallel effort. This database is probably the largest source of high-temperature, creep-fatigue test data available in the public domain and can be used with other life prediction methods as well. This users manual, software, and database are all in the public domain and are available through COSMIC (382 East Broad Street, Athens, GA 30602; (404) 542-3265, FAX (404) 542-4807). Two disks accompany this manual. The first disk contains the source code, executable files, and sample output from these programs. The second disk contains the creep-fatigue data in a format compatible with these programs.
Modifications to the algal growth inhibition test for use as a regulatory assay
DOE Office of Scientific and Technical Information (OSTI.GOV)
Geis, S.W.; Fleming, K.L.; Korthals, E.T.
2000-01-01
Biological assays using aquatic invertebrates and fish do not necessarily predict protection levels for primary producers such as algae and aquatic macrophytes. State regulatory programs may not be protecting the environment from many phytotoxic compounds. Recent modifications of the US Environmental Protection Agency's algal test were evaluated for their potential use as a regulatory assay. Primary goals of this investigation were to downsize the algal assay and to evaluate various methods of automation. Disposable microplates with 2-ml sample wells were evaluated as an alternative testing chamber for the 96-h growth inhibition test with Raphidocelis subcapitata (formerly known as Selenastrum capricornutum).more » The authors compared the standardized Erlenmeyer {reg_sign} flask test to the microplate test using CuCl{sub 2}, NaCl, phenol, ZnCl{sub 2}, and a surfactant. They noted improved control performance with the microplate test, whereas median inhibitory concentration values were similar for both methods. Other procedures they addressed included the use of EDTA, filtration of samples, and the effect of colored samples on algal growth. They also evaluated growth estimates by comparing manual cell counting to more automated growth estimates using fluorescence and absorbance endpoints. The use of fluorescence and absorbance measurements demonstrated reductions in replicate variability over manual counting and may offer time-saving alternatives for laboratory analysts.« less
Test and evaluation procedures for Sandia's Teraflops Operating System (TOS) on Janus.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Barnette, Daniel Wayne
This report describes the test and evaluation methods by which the Teraflops Operating System, or TOS, that resides on Sandia's massively-parallel computer Janus is verified for production release. Also discussed are methods used to build TOS before testing and evaluating, miscellaneous utility scripts, a sample test plan, and a proposed post-test method for quickly examining the large number of test results. The purpose of the report is threefold: (1) to provide a guide to T&E procedures, (2) to aid and guide others who will run T&E procedures on the new ASCI Red Storm machine, and (3) to document some ofmore » the history of evaluation and testing of TOS. This report is not intended to serve as an exhaustive manual for testers to conduct T&E procedures.« less
Manual therapy in osteoarthritis of the hip: outcome in subgroups of patients.
Hoeksma, H L; Dekker, J; Ronday, H K; Breedveld, F C; Van den Ende, C H M
2005-04-01
To investigate whether manual therapy has particular benefit in subgroups of patients defined on the basis of hip function, range of joint motion, pain and radiological deterioration. The study was performed in the out-patient clinic of physical therapy of a large hospital. Data on 109 patients with OA of the hip (clinical ACR criteria) participating in a randomized clinical trial on the effects of manual therapy were used. The outcomes for hip function (Harris hip score), range of joint motion (ROM) and pain (VAS) were compared for specific subgroups. Subgroups were assigned by the median split method. The interaction effect between subgroup and treatment was tested using multiple regression analysis. No differences were observed in the effect of manual therapy in specific subgroups of patients defined on the basis of baseline levels of hip function, pain and ROM. On the basis of radiological grading of osteoarthritis (OA), we found that patients with severe radiological grading of OA had significantly worse outcome on ROM as a result of manual therapy than patients with mild or moderate radiological grading of OA. A significant interaction effect was found for only 1 out of 12 hypotheses investigated. Therefore, we conclude that there is no evidence for the particular benefit of manual therapy in subgroups of patients.
Development of a novel constellation based landmark detection algorithm
NASA Astrophysics Data System (ADS)
Ghayoor, Ali; Vaidya, Jatin G.; Johnson, Hans J.
2013-03-01
Anatomical landmarks such as the anterior commissure (AC) and posterior commissure (PC) are commonly used by researchers for co-registration of images. In this paper, we present a novel, automated approach for landmark detection that combines morphometric constraining and statistical shape models to provide accurate estimation of landmark points. This method is made robust to large rotations in initial head orientation by extracting extra information of the eye centers using a radial Hough transform and exploiting the centroid of head mass (CM) using a novel estimation approach. To evaluate the effectiveness of this method, the algorithm is trained on a set of 20 images with manually selected landmarks, and a test dataset is used to compare the automatically detected against the manually detected landmark locations of the AC, PC, midbrain-pons junction (MPJ), and fourth ventricle notch (VN4). The results show that the proposed method is accurate as the average error between the automatically and manually labeled landmark points is less than 1 mm. Also, the algorithm is highly robust as it was successfully run on a large dataset that included different kinds of images with various orientation, spacing, and origin.
Supervised segmentation of microelectrode recording artifacts using power spectral density.
Bakstein, Eduard; Schneider, Jakub; Sieger, Tomas; Novak, Daniel; Wild, Jiri; Jech, Robert
2015-08-01
Appropriate detection of clean signal segments in extracellular microelectrode recordings (MER) is vital for maintaining high signal-to-noise ratio in MER studies. Existing alternatives to manual signal inspection are based on unsupervised change-point detection. We present a method of supervised MER artifact classification, based on power spectral density (PSD) and evaluate its performance on a database of 95 labelled MER signals. The proposed method yielded test-set accuracy of 90%, which was close to the accuracy of annotation (94%). The unsupervised methods achieved accuracy of about 77% on both training and testing data.
An Approach to Evaluate Blurriness in Retinal Images with Vitreous Opacity for Cataract Diagnosis
Xu, Liang
2017-01-01
Cataract is one of the leading causes of blindness in the world's population. A method to evaluate blurriness for cataract diagnosis in retinal images with vitreous opacity is proposed in this paper. Three types of features are extracted, which include pixel number of visible structures, mean contrast between vessels and background, and local standard deviation. To avoid the wrong detection of vitreous opacity as retinal structures, a morphological method is proposed to detect and remove such lesions from retinal visible structure segmentation. Based on the extracted features, a decision tree is trained to classify retinal images into five grades of blurriness. The proposed approach was tested using 1355 clinical retinal images, and the accuracies of two-class classification and five-grade grading compared with that of manual grading are 92.8% and 81.1%, respectively. The kappa value between automatic grading and manual grading is 0.74 in five-grade grading, in which both variance and P value are less than 0.001. Experimental results show that the grading difference between automatic grading and manual grading is all within 1 grade, which is much improvement compared with that of other available methods. The proposed grading method provides a universal measure of cataract severity and can facilitate the decision of cataract surgery. PMID:29065620
NASA Astrophysics Data System (ADS)
Ibrahim, Dheyaa Ahmed; Al-Assam, Hisham; Du, Hongbo; Jassim, Sabah
2017-05-01
Ovarian masses are categorised into different types of malignant and benign. In order to optimize patient treatment, it is necessary to carry out pre-operational characterisation of the suspect ovarian mass to determine its category. Ultrasound imaging has been widely used in differentiating malignant from benign cases due to its safe and non-intrusive nature, and can be used for determining the number of cysts in the ovary. Presently, the gynaecologist is tasked with manually counting the number of cysts shown on the ultrasound image. This paper proposes, a new approach that automatically segments the ovarian masses and cysts from a static B-mode image. Initially, the method uses a trainable segmentation procedure and a trained neural network classifier to accurately identify the position of the masses and cysts. After that, the borders of the masses can be appraised using watershed transform. The effectiveness of the proposed method has been tested by comparing the number of cysts identified by the method against the manual examination by a gynaecologist. A total of 65 ultrasound images were used for the comparison, and the results showed that the proposed solution is a viable alternative to the manual counting method for accurately determining the number of cysts in a US ovarian image.
Ma, Junlong; Wang, Chengbin; Yue, Jiaxin; Li, Mianyang; Zhang, Hongrui; Ma, Xiaojing; Li, Xincui; Xue, Dandan; Qing, Xiaoyan; Wang, Shengjiang; Xiang, Daijun; Cong, Yulong
2013-01-01
Several automated urine sediment analyzers have been introduced to clinical laboratories. Automated microscopic pattern recognition is a new technique for urine particle analysis. We evaluated the analytical and diagnostic performance of the UriSed automated microscopic analyzer and compared with manual microscopy for urine sediment analysis. Precision, linearity, carry-over, and method comparison were carried out. A total of 600 urine samples sent for urinalysis were assessed using the UriSed automated microscopic analyzer and manual microscopy. Within-run and between-run precision of the UriSed for red blood cells (RBC) and white blood cells (WBC) were acceptable at all levels (CV < 20%). Within-run and between-run imprecision of the UriSed testing for cast, squamous epithelial cells (EPI), and bacteria (BAC) were good at middle level and high level (CV < 20%). The linearity analysis revealed substantial agreement between the measured value and the theoretical value of the UriSed for RBC, WBC, cast, EPI, and BAC (r > 0.95). There was no carry-over. RBC, WBC, and squamous epithelial cells with sensitivities and specificities were more than 80% in this study. There is substantial agreement between the UriSed automated microscopic analyzer and the manual microscopy methods. The UriSed provides for a rapid turnaround time.
Alfa, Michelle J; Fatima, Iram; Olson, Nancy
2013-03-01
The study objective was to verify that the adenosine triphosphate (ATP) benchmark of <200 relative light units (RLUs) was achievable in a busy endoscopy clinic that followed the manufacturer's manual cleaning instructions. All channels from patient-used colonoscopes (20) and duodenoscopes (20) in a tertiary care hospital endoscopy clinic were sampled after manual cleaning and tested for residual ATP. The ATP test benchmark for adequate manual cleaning was set at <200 RLUs. The benchmark for protein was <6.4 μg/cm(2), and, for bioburden, it was <4-log10 colony-forming units/cm(2). Our data demonstrated that 96% (115/120) of channels from 20 colonoscopes and 20 duodenoscopes evaluated met the ATP benchmark of <200 RLUs. The 5 channels that exceeded 200 RLUs were all elevator guide-wire channels. All 120 of the manually cleaned endoscopes tested had protein and bioburden levels that were compliant with accepted benchmarks for manual cleaning for suction-biopsy, air-water, and auxiliary water channels. Our data confirmed that, by following the endoscope manufacturer's manual cleaning recommendations, 96% of channels in gastrointestinal endoscopes would have <200 RLUs for the ATP test kit evaluated and would meet the accepted clean benchmarks for protein and bioburden. Copyright © 2013 Association for Professionals in Infection Control and Epidemiology, Inc. Published by Mosby, Inc. All rights reserved.
ERIC Educational Resources Information Center
Bureau of Employment Security (DOL), Washington, DC.
THE NINE APTITUDES MEASURED BY THE GENERAL APTITUDE TEST BATTERY ARE INTELLIGENCE, VERBAL APTITUDE, NUMERICAL APTITUDE, SPATIAL APTITUDE, FORM PERCEPTION, CLERICAL PERCEPTION, MOTOR COORDINATION, FINGER DEXTERITY, AND MANUAL DEXTERITY. THIS MANUAL PRESENTS (1) PERCENTILE EQUIVALENTS OF APTITUDE OR STANDARD SCORES FOR ADULTS, 10TH GRADERS, AND 9TH…
NASA Technical Reports Server (NTRS)
Bull, William B. (Compiler); Pinoli, Pat C. (Compiler); Upton, Cindy G. (Compiler); Day, Tony (Compiler); Hill, Keith (Compiler); Stone, Frank (Compiler); Hall, William B.
1994-01-01
This report is a compendium of the presentations of the 12th biannual meeting of the Industry Advisory Committee under the Solid Propulsion Integrity Program. A complete transcript of the welcoming talks is provided. Presentation outlines and overheads are included for the other sessions: SPIP Overview, Past, Current and Future Activity; Test Methods Manual and Video Tape Library; Air Force Developed Computer Aided Cure Program and SPC/TQM Experience; Magneto-Optical mapper (MOM), Joint Army/NASA program to assess composite integrity; Permeability Testing; Moisture Effusion Testing by Karl Fischer Analysis; Statistical Analysis of Acceptance Test Data; NMR Phenolic Resin Advancement; Constituent Testing Highlights on the LDC Optimization Program; Carbon Sulfur Study, Performance Related Testing; Current Rayon Specifications and Future Availability; RSRM/SPC Implementation; SRM Test Methods, Delta/Titan/FBM/RSRM; and Open Forum on Performance Based Acceptance Testing -- Industry Experience.
DESIGN MANUAL: PHOSPHORUS REMOVAL
This manual summarizes process design information for the best developed methods for removing phosphorus from wastewater. his manual discusses several proven phosphorus removal methods, including phosphorus removal obtainable through biological activity as well as chemical precip...
Experimental analysis of drilling process in cortical bone.
Wang, Wendong; Shi, Yikai; Yang, Ning; Yuan, Xiaoqing
2014-02-01
Bone drilling is an essential part in orthopaedics, traumatology and bone biopsy. Prediction and control of drilling forces and torque are critical to the success of operations involving bone drilling. This paper studied the drilling force, torque and drilling process with automatic and manual drill penetrating into bovine cortical bone. The tests were performed on a drilling system which is used to drill and measure forces and torque during drilling. The effects of drilling speed, feed rate and drill bit diameter on force and torque were discussed separately. The experimental results were proven to be in accordance with the mathematic expressions introduced in this paper. The automatic drilling saved drilling time by 30-60% in the tested range and created less vibration, compared to manual drilling. The deviation between maximum and average force of the automatic drilling was 5N but 25N for manual drilling. To conclude, using the automatic method has significant advantages in control drilling force, torque and drilling process in bone drilling. Copyright © 2013 IPEM. Published by Elsevier Ltd. All rights reserved.
Samaan, Michael A; Schultz, Brooke; Popovic, Tijana; Souza, Richard B; Majumdar, Sharmila
2017-01-01
Background Performance tests are important to characterize patient disabilities and functional changes. The Osteoarthritis Research Society International and others recommend the 30-second Chair Stand Test and Stair Climb Test, among others, as core tests that capture two distinct types of disability during activities of daily living. However, these two tests are limited by current protocols of testing in clinics. There is a need for an alternative that allows remote testing of functional capabilities during these tests in the osteoarthritis patient population. Objective Objectives are to (1) develop an app for testing the functionality of an iPhone’s accelerometer and gravity sensor and (2) conduct a pilot study objectively evaluating the criterion validity and test-retest reliability of outcome variables obtained from these sensors during the 30-second Chair Stand Test and Stair Climb Test. Methods An iOS app was developed with data collection capabilities from the built-in iPhone accelerometer and gravity sensor tools and linked to Google Firebase. A total of 24 subjects performed the 30-second Chair Stand Test with an iPhone accelerometer collecting data and an external rater manually counting sit-to-stand repetitions. A total of 21 subjects performed the Stair Climb Test with an iPhone gravity sensor turned on and an external rater timing the duration of the test on a stopwatch. App data from Firebase were converted into graphical data and exported into MATLAB for data filtering. Multiple iterations of a data processing algorithm were used to increase robustness and accuracy. MATLAB-generated outcome variables were compared to the manually determined outcome variables of each test. Pearson’s correlation coefficients (PCCs), Bland-Altman plots, intraclass correlation coefficients (ICCs), standard errors of measurement, and repeatability coefficients were generated to evaluate criterion validity, agreement, and test-retest reliability of iPhone sensor data against gold-standard manual measurements. Results App accelerometer data during the 30-second Chair Stand Test (PCC=.890) and gravity sensor data during the Stair Climb Test (PCC=.865) were highly correlated to gold-standard manual measurements. Greater than 95% of values on Bland-Altman plots comparing the manual data to the app data fell within the 95% limits of agreement. Strong intraclass correlation was found for trials of the 30-second Chair Stand Test (ICC=.968) and Stair Climb Test (ICC=.902). Standard errors of measurement for both tests were found to be within acceptable thresholds for MATLAB. Repeatability coefficients for the 30-second Chair Stand Test and Stair Climb Test were 0.629 and 1.20, respectively. Conclusions App-based performance testing of the 30-second Chair Stand Test and Stair Climb Test is valid and reliable, suggesting its applicability to future, larger-scale studies in the osteoarthritis patient population. PMID:29079549
Pliasunova, S A; Balugian, R Sh; Khmel'nitskiĭ, K E; Medovyĭ, V S; Parpara, A A; Piatnitskiĭ, A M; Sokolinskiĭ, B Z; Dem'ianov, V L; Nikolaenko, D S
2006-10-01
The paper presents the results of medical tests of a group of computer-aided procedures for microscopic analysis by means of a MECOS-Ts2 complex (ZAO "MECOS", Russia), which have been conducted at the Republican Children's Clinical Hospital, the Research Institute of Emergency Pediatric Surgery and Traumatology, and Moscow City Clinical Hospital No. 23. Computer-aided procedures for calculating the differential count and for analyzing the morphology of red blood cells were tested on blood smears from a total of 443 patients and donors, computer-aided calculation of the count of reticulocytes was tested on 318 smears. The tests were carried out under the US standard NCCLS-H20A. Manual microscopy (443 smears) and flow blood analysis on a Coulter GEN*S (125 smears) were used as reference methods. The quality of collection of samples and laboriousness were additionally assessed. The certified MECOS-Ts2 subsystems were additionally used as reference tools. The tests indicated the advantage of computer-aided MECOS-Tsl2 complex microscopy over manual microscopy.
2013-01-01
Background T2-weighted cardiovascular magnetic resonance (CMR) is clinically-useful for imaging the ischemic area-at-risk and amount of salvageable myocardium in patients with acute myocardial infarction (MI). However, to date, quantification of oedema is user-defined and potentially subjective. Methods We describe a highly automatic framework for quantifying myocardial oedema from bright blood T2-weighted CMR in patients with acute MI. Our approach retains user input (i.e. clinical judgment) to confirm the presence of oedema on an image which is then subjected to an automatic analysis. The new method was tested on 25 consecutive acute MI patients who had a CMR within 48 hours of hospital admission. Left ventricular wall boundaries were delineated automatically by variational level set methods followed by automatic detection of myocardial oedema by fitting a Rayleigh-Gaussian mixture statistical model. These data were compared with results from manual segmentation of the left ventricular wall and oedema, the current standard approach. Results The mean perpendicular distances between automatically detected left ventricular boundaries and corresponding manual delineated boundaries were in the range of 1-2 mm. Dice similarity coefficients for agreement (0=no agreement, 1=perfect agreement) between manual delineation and automatic segmentation of the left ventricular wall boundaries and oedema regions were 0.86 and 0.74, respectively. Conclusion Compared to standard manual approaches, the new highly automatic method for estimating myocardial oedema is accurate and straightforward. It has potential as a generic software tool for physicians to use in clinical practice. PMID:23548176
Correlation and agreement of a digital and conventional method to measure arch parameters.
Nawi, Nes; Mohamed, Alizae Marny; Marizan Nor, Murshida; Ashar, Nor Atika
2018-01-01
The aim of the present study was to determine the overall reliability and validity of arch parameters measured digitally compared to conventional measurement. A sample of 111 plaster study models of Down syndrome (DS) patients were digitized using a blue light three-dimensional (3D) scanner. Digital and manual measurements of defined parameters were performed using Geomagic analysis software (Geomagic Studio 2014 software, 3D Systems, Rock Hill, SC, USA) on digital models and with a digital calliper (Tuten, Germany) on plaster study models. Both measurements were repeated twice to validate the intraexaminer reliability based on intraclass correlation coefficients (ICCs) using the independent t test and Pearson's correlation, respectively. The Bland-Altman method of analysis was used to evaluate the agreement of the measurement between the digital and plaster models. No statistically significant differences (p > 0.05) were found between the manual and digital methods when measuring the arch width, arch length, and space analysis. In addition, all parameters showed a significant correlation coefficient (r ≥ 0.972; p < 0.01) between all digital and manual measurements. Furthermore, a positive agreement between digital and manual measurements of the arch width (90-96%), arch length and space analysis (95-99%) were also distinguished using the Bland-Altman method. These results demonstrate that 3D blue light scanning and measurement software are able to precisely produce 3D digital model and measure arch width, arch length, and space analysis. The 3D digital model is valid to be used in various clinical applications.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Morshed, Nader; Lawrence Berkeley National Laboratory, Berkeley, CA 94720; Echols, Nathaniel, E-mail: nechols@lbl.gov
2015-05-01
A method to automatically identify possible elemental ions in X-ray crystal structures has been extended to use support vector machine (SVM) classifiers trained on selected structures in the PDB, with significantly improved sensitivity over manually encoded heuristics. In the process of macromolecular model building, crystallographers must examine electron density for isolated atoms and differentiate sites containing structured solvent molecules from those containing elemental ions. This task requires specific knowledge of metal-binding chemistry and scattering properties and is prone to error. A method has previously been described to identify ions based on manually chosen criteria for a number of elements. Here,more » the use of support vector machines (SVMs) to automatically classify isolated atoms as either solvent or one of various ions is described. Two data sets of protein crystal structures, one containing manually curated structures deposited with anomalous diffraction data and another with automatically filtered, high-resolution structures, were constructed. On the manually curated data set, an SVM classifier was able to distinguish calcium from manganese, zinc, iron and nickel, as well as all five of these ions from water molecules, with a high degree of accuracy. Additionally, SVMs trained on the automatically curated set of high-resolution structures were able to successfully classify most common elemental ions in an independent validation test set. This method is readily extensible to other elemental ions and can also be used in conjunction with previous methods based on a priori expectations of the chemical environment and X-ray scattering.« less
NASA Astrophysics Data System (ADS)
Luiza Bondar, M.; Hoogeman, Mischa; Schillemans, Wilco; Heijmen, Ben
2013-08-01
For online adaptive radiotherapy of cervical cancer, fast and accurate image segmentation is required to facilitate daily treatment adaptation. Our aim was twofold: (1) to test and compare three intra-patient automated segmentation methods for the cervix-uterus structure in CT-images and (2) to improve the segmentation accuracy by including prior knowledge on the daily bladder volume or on the daily coordinates of implanted fiducial markers. The tested methods were: shape deformation (SD) and atlas-based segmentation (ABAS) using two non-rigid registration methods: demons and a hierarchical algorithm. Tests on 102 CT-scans of 13 patients demonstrated that the segmentation accuracy significantly increased by including the bladder volume predicted with a simple 1D model based on a manually defined bladder top. Moreover, manually identified implanted fiducial markers significantly improved the accuracy of the SD method. For patients with large cervix-uterus volume regression, the use of CT-data acquired toward the end of the treatment was required to improve segmentation accuracy. Including prior knowledge, the segmentation results of SD (Dice similarity coefficient 85 ± 6%, error margin 2.2 ± 2.3 mm, average time around 1 min) and of ABAS using hierarchical non-rigid registration (Dice 82 ± 10%, error margin 3.1 ± 2.3 mm, average time around 30 s) support their use for image guided online adaptive radiotherapy of cervical cancer.
Bondar, M Luiza; Hoogeman, Mischa; Schillemans, Wilco; Heijmen, Ben
2013-08-07
For online adaptive radiotherapy of cervical cancer, fast and accurate image segmentation is required to facilitate daily treatment adaptation. Our aim was twofold: (1) to test and compare three intra-patient automated segmentation methods for the cervix-uterus structure in CT-images and (2) to improve the segmentation accuracy by including prior knowledge on the daily bladder volume or on the daily coordinates of implanted fiducial markers. The tested methods were: shape deformation (SD) and atlas-based segmentation (ABAS) using two non-rigid registration methods: demons and a hierarchical algorithm. Tests on 102 CT-scans of 13 patients demonstrated that the segmentation accuracy significantly increased by including the bladder volume predicted with a simple 1D model based on a manually defined bladder top. Moreover, manually identified implanted fiducial markers significantly improved the accuracy of the SD method. For patients with large cervix-uterus volume regression, the use of CT-data acquired toward the end of the treatment was required to improve segmentation accuracy. Including prior knowledge, the segmentation results of SD (Dice similarity coefficient 85 ± 6%, error margin 2.2 ± 2.3 mm, average time around 1 min) and of ABAS using hierarchical non-rigid registration (Dice 82 ± 10%, error margin 3.1 ± 2.3 mm, average time around 30 s) support their use for image guided online adaptive radiotherapy of cervical cancer.
Validation of adenosine triphosphate to audit manual cleaning of flexible endoscope channels.
Alfa, Michelle J; Fatima, Iram; Olson, Nancy
2013-03-01
Compliance with cleaning of flexible endoscope channels cannot be verified using visual inspection. Adenosine triphosphate (ATP) has been suggested as a possible rapid cleaning monitor for flexible endoscope channels. There have not been published validation studies to specify the level of ATP that indicates inadequate cleaning has been achieved. The objective of this study was to validate the Clean-Trace (3M Inc, St. Paul, MN) ATP water test method for monitoring manual cleaning of flexible endoscopes. This was a simulated use study using a duodenoscope as the test device. Artificial test soil containing 10(6) colony-forming units of Pseudomonas aeruginosa and Enterococcus faecalis was used to perfuse all channels. The flush sample method for the suction-biopsy (L1) or air-water channel (L2) using 40 and 20 mLs sterile reverse osmosis water, respectively, was validated. Residuals of ATP, protein, hemoglobin, and bioburden were quantitated from channel samples taken from uncleaned, partially cleaned, and fully cleaned duodenoscopes. The benchmarks for clean were as follows: <6.4 μg/cm(2) protein, <2.2 μg/cm(2) hemoglobin, and <4-log10 colony-forming units/cm(2) bioburden. The average ATP in clean channel samples was 27.7 RLUs and 154 RLUs for L1 and L2, respectively (<200 RLUs for all channels). The average protein, hemoglobin, and bioburden benchmarks were achieved if <200 RLUs were detected. If the channel sample was >200 RLUs, the residual organic and bioburden levels would exceed the acceptable benchmarks. Our data validated that flexible endoscopes that have complete manual cleaning will have <200 RLUs by the Clean-Trace ATP test. Copyright © 2013 Association for Professionals in Infection Control and Epidemiology, Inc. Published by Mosby, Inc. All rights reserved.
Urinalysis: The Automated Versus Manual Techniques; Is It Time To Change?.
Ahmed, Asmaa Ismail; Baz, Heba; Lotfy, Sarah
2016-01-01
Urinalysis is the third major test in clinical laboratory. Manual technique imprecision urges the need for a rapid reliable automated test. We evaluated the H800-FUSIOO automatic urine sediment analyzer and compared it to the manual urinalysis technique to determine if it may be a competitive substitute in laboratories of central hospitals. 1000 urine samples were examined by the two methods in parallel. Agreement, precision, carryover, drift, sensitivity, specificity, and practicability criteria were tested. Agreement ranged from excellent to good for all urine semi-quantitative components (K > 0.4, p = 0.000), except for granular casts (K = 0.317, p = 0.000). Specific gravity results correlated well between the two methods (r = 0.884, p = 0.000). RBCS and WBCs showed moderate correlation (r = 0.42, p = 0.000) and (r = 0.44, p = 0.000), respectively. The auto-analyzer's within-run precision was > 75% for all semi-quantitative components except for proteins (50% precision). This finding in addition to the granular casts poor agreement indicate the necessity of operator interference at the critical cutoff values. As regards quantitative contents, RBCs showed a mean of 69.8 +/- 3.95, C.V. = 5.7, WBCs showed a mean of 38.9 +/- 1.9, C.V. = 4.9). Specific gravity, pH, microalbumin, and creatinine also showed good precision results with C.Vs of 0.000, 2.6, 9.1, and 0.00 respectively. In the between run precision, positive control showed good precision (C.V. = 2.9), while negative control's C.V. was strikingly high (C.V. = 127). Carryover and drift studies were satisfactory. Manual examination of inter-observer results showed major discrepancies (< 60% similar readings), while intra-observer's results correlated well with each other (r = 0.99, p = 0.000). Automation of urinalysis decreases observer-associated variation and offers prompt competitive results when standardized for screening away from the borderline cutoffs.
Automated posterior cranial fossa volumetry by MRI: applications to Chiari malformation type I.
Bagci, A M; Lee, S H; Nagornaya, N; Green, B A; Alperin, N
2013-09-01
Quantification of PCF volume and the degree of PCF crowdedness were found beneficial for differential diagnosis of tonsillar herniation and prediction of surgical outcome in CMI. However, lack of automated methods limits the clinical use of PCF volumetry. An atlas-based method for automated PCF segmentation tailored for CMI is presented. The method performance is assessed in terms of accuracy and spatial overlap with manual segmentation. The degree of association between PCF volumes and the lengths of previously proposed linear landmarks is reported. T1-weighted volumetric MR imaging data with 1-mm isotropic resolution obtained with the use of a 3T scanner from 14 patients with CMI and 3 healthy subjects were used for the study. Manually delineated PCF from 9 patients was used to establish a CMI-specific reference for an atlas-based automated PCF parcellation approach. Agreement between manual and automated segmentation of 5 different CMI datasets was verified by means of the t test. Measurement reproducibility was established through the use of 2 repeated scans from 3 healthy subjects. Degree of linear association between PCF volume and 6 linear landmarks was determined by means of Pearson correlation. PCF volumes measured by use of the automated method and with manual delineation were similar, 196.2 ± 8.7 mL versus 196.9 ± 11.0 mL, respectively. The mean relative difference of -0.3 ± 1.9% was not statistically significant. Low measurement variability, with a mean absolute percentage value of 0.6 ± 0.2%, was achieved. None of the PCF linear landmarks were significantly associated with PCF volume. PCF and tissue content volumes can be reliably measured in patients with CMI by use of an atlas-based automated segmentation method.
NASA Technical Reports Server (NTRS)
Green, C.
1971-01-01
Guidelines of the methods and applications used in vibration technology at the MSFC are presented. The purpose of the guidelines is to provide a practical tool for coordination and understanding between industry and government groups concerned with vibration of systems and equipments. Topics covered include measuring, reducing, analyzing, and methods for obtaining simulated environments and formulating vibration specifications. Methods for vibration and shock testing, theoretical aspects of data processing, vibration response analysis, and techniques of designing for vibration are also presented.
Karell, Mara A; Langstaff, Helen K; Halazonetis, Demetrios J; Minghetti, Caterina; Frelat, Mélanie; Kranioti, Elena F
2016-09-01
The commingling of human remains often hinders forensic/physical anthropologists during the identification process, as there are limited methods to accurately sort these remains. This study investigates a new method for pair-matching, a common individualization technique, which uses digital three-dimensional models of bone: mesh-to-mesh value comparison (MVC). The MVC method digitally compares the entire three-dimensional geometry of two bones at once to produce a single value to indicate their similarity. Two different versions of this method, one manual and the other automated, were created and then tested for how well they accurately pair-matched humeri. Each version was assessed using sensitivity and specificity. The manual mesh-to-mesh value comparison method was 100 % sensitive and 100 % specific. The automated mesh-to-mesh value comparison method was 95 % sensitive and 60 % specific. Our results indicate that the mesh-to-mesh value comparison method overall is a powerful new tool for accurately pair-matching commingled skeletal elements, although the automated version still needs improvement.
32 CFR 634.35 - Chemical testing policies and procedures.
Code of Federal Regulations, 2010 CFR
2010-07-01
... 32 National Defense 4 2010-07-01 2010-07-01 true Chemical testing policies and procedures. 634.35... Chemical testing policies and procedures. (a) Validity of chemical testing. Results of chemical testing are... instruction manual. (iv) Perform preventive maintenance as required by the instruction manual. (c) Chemical...
32 CFR 634.35 - Chemical testing policies and procedures.
Code of Federal Regulations, 2011 CFR
2011-07-01
... 32 National Defense 4 2011-07-01 2011-07-01 false Chemical testing policies and procedures. 634.35... Chemical testing policies and procedures. (a) Validity of chemical testing. Results of chemical testing are... instruction manual. (iv) Perform preventive maintenance as required by the instruction manual. (c) Chemical...
32 CFR 634.35 - Chemical testing policies and procedures.
Code of Federal Regulations, 2012 CFR
2012-07-01
... 32 National Defense 4 2012-07-01 2011-07-01 true Chemical testing policies and procedures. 634.35... Chemical testing policies and procedures. (a) Validity of chemical testing. Results of chemical testing are... instruction manual. (iv) Perform preventive maintenance as required by the instruction manual. (c) Chemical...
32 CFR 634.35 - Chemical testing policies and procedures.
Code of Federal Regulations, 2014 CFR
2014-07-01
... 32 National Defense 4 2014-07-01 2013-07-01 true Chemical testing policies and procedures. 634.35... Chemical testing policies and procedures. (a) Validity of chemical testing. Results of chemical testing are... instruction manual. (iv) Perform preventive maintenance as required by the instruction manual. (c) Chemical...
32 CFR 634.35 - Chemical testing policies and procedures.
Code of Federal Regulations, 2013 CFR
2013-07-01
... 32 National Defense 4 2013-07-01 2013-07-01 false Chemical testing policies and procedures. 634.35... Chemical testing policies and procedures. (a) Validity of chemical testing. Results of chemical testing are... instruction manual. (iv) Perform preventive maintenance as required by the instruction manual. (c) Chemical...
DiPaola, Matthew J; DiPaola, Christian P; Conrad, Bryan P; Horodyski, MaryBeth; Del Rossi, Gianluca; Sawers, Andrew; Bloch, David; Rechtine, Glenn R
2008-06-01
A study of spine biomechanics in a cadaver model. To quantify motion in multiple axes created by transfer methods from stretcher to operating table in the prone position in a cervical global instability model. Patients with an unstable cervical spine remain at high risk for further secondary injury until their spine is adequately surgically stabilized. Previous studies have revealed that collars have significant, but limited benefit in preventing cervical motion when manually transferring patients. The literature proposes multiple methods of patient transfer, although no one method has been universally adopted. To date, no study has effectively evaluated the relationship between spine motion and various patient transfer methods to an operating room table for prone positioning. A global instability was surgically created at C5-6 in 4 fresh cadavers with no history of spine pathology. All cadavers were tested both with and without a rigid cervical collar in the intact and unstable state. Three headrest permutations were evaluated Mayfield (SM USA Inc), Prone View (Dupaco, Oceanside, CA), and Foam Pillow (OSI, Union City, CA). A trained group of medical staff performed each of 2 transfer methods: the "manual" and the "Jackson table" transfer. The manual technique entailed performing a standard rotation of the supine patient on a stretcher to the prone position on the operating room table with in-line manual cervical stabilization. The "Jackson" technique involved sliding the supine patient to the Jackson table (OSI, Union City, CA) with manual in-line cervical stabilization, securing them to the table, then initiating the table's lock and turn mechanism and rotating them into a prone position. An electromagnetic tracking device captured angular motion between the C5 and C6 vertebral segments. Repeated measures statistical analysis was performed to evaluate the following conditions: collar use (2 levels), headrest (3 levels), and turning technique (2 levels). For all measures, there was significantly more cervical spine motion during manual prone positioning compared with using the Jackson table. The use of a collar provided a slight reduction in motion in all the planes of movement; however, this was only significantly different from the no collar condition in axial rotation. Differences in gross motion between the headrest type were observed in lateral bending (Foam Pillow
Paproki, Anthony; Engstrom, Craig; Strudwick, Mark; Wilson, Katharine J; Surowiec, Rachel K; Ho, Charles; Crozier, Stuart; Fripp, Jurgen
2017-10-01
This study aimed to evaluate the accuracy of an automated method for segmentation and T2 mapping of the medial meniscus (MM) and lateral meniscus (LM) in clinical magnetic resonance images from patients with acute knee injury. Eighty patients scheduled for surgery of an anterior cruciate ligament or meniscal injury underwent magnetic resonance imaging of the knee (multiplanar two-dimensional [2D] turbo spin echo [TSE] or three-dimensional [3D]-TSE examinations, T2 mapping). Each meniscus was automatically segmented from the 2D-TSE (composite volume) or 3D-TSE images, auto-partitioned into anterior, mid, and posterior regions, and co-registered onto the T2 maps. The Dice similarity index (spatial overlap) was calculated between automated and manual segmentations of 2D-TSE (15 patients), 3D-TSE (16 patients), and corresponding T2 maps (31 patients). Pearson and intraclass correlation coefficients (ICC) were calculated between automated and manual T2 values. T2 values were compared (Wilcoxon rank sum tests) between torn and non-torn menisci for the subset of patients with both manual and automated segmentations to compare statistical outcomes of both methods. The Dice similarity index values for the 2D-TSE, 3D-TSE, and T2 map volumes, respectively, were 76.4%, 84.3%, and 75.2% for the MM and 76.4%, 85.1%, and 76.1% for the LM. There were strong correlations between automated and manual T2 values (r MM = 0.95, ICC MM = 0.94; r LM = 0.97, ICC LM = 0.97). For both the manual and the automated methods, T2 values were significantly higher in torn than in non-torn MM for the full meniscus and its subregions (P < .05). Non-torn LM had higher T2 values than non-torn MM (P < .05). The present automated method offers a promising alternative to manual T2 mapping analyses of the menisci and a considerable advance for integration into clinical workflows. Copyright © 2017 The Association of University Radiologists. All rights reserved.
Werner-Wasik, Maria; Nelson, Arden D; Choi, Walter; Arai, Yoshio; Faulhaber, Peter F; Kang, Patrick; Almeida, Fabio D; Xiao, Ying; Ohri, Nitin; Brockway, Kristin D; Piper, Jonathan W; Nelson, Aaron S
2012-03-01
To evaluate the accuracy and consistency of a gradient-based positron emission tomography (PET) segmentation method, GRADIENT, compared with manual (MANUAL) and constant threshold (THRESHOLD) methods. Contouring accuracy was evaluated with sphere phantoms and clinically realistic Monte Carlo PET phantoms of the thorax. The sphere phantoms were 10-37 mm in diameter and were acquired at five institutions emulating clinical conditions. One institution also acquired a sphere phantom with multiple source-to-background ratios of 2:1, 5:1, 10:1, 20:1, and 70:1. One observer segmented (contoured) each sphere with GRADIENT and THRESHOLD from 25% to 50% at 5% increments. Subsequently, seven physicians segmented 31 lesions (7-264 mL) from 25 digital thorax phantoms using GRADIENT, THRESHOLD, and MANUAL. For spheres <20 mm in diameter, GRADIENT was the most accurate with a mean absolute % error in diameter of 8.15% (10.2% SD) compared with 49.2% (51.1% SD) for 45% THRESHOLD (p < 0.005). For larger spheres, the methods were statistically equivalent. For varying source-to-background ratios, GRADIENT was the most accurate for spheres >20 mm (p < 0.065) and <20 mm (p < 0.015). For digital thorax phantoms, GRADIENT was the most accurate (p < 0.01), with a mean absolute % error in volume of 10.99% (11.9% SD), followed by 25% THRESHOLD at 17.5% (29.4% SD), and MANUAL at 19.5% (17.2% SD). GRADIENT had the least systematic bias, with a mean % error in volume of -0.05% (16.2% SD) compared with 25% THRESHOLD at -2.1% (34.2% SD) and MANUAL at -16.3% (20.2% SD; p value <0.01). Interobserver variability was reduced using GRADIENT compared with both 25% THRESHOLD and MANUAL (p value <0.01, Levene's test). GRADIENT was the most accurate and consistent technique for target volume contouring. GRADIENT was also the most robust for varying imaging conditions. GRADIENT has the potential to play an important role for tumor delineation in radiation therapy planning and response assessment. Copyright © 2012. Published by Elsevier Inc.
Tafe, Laura J; Allen, Samantha F; Steinmetz, Heather B; Dokus, Betty A; Cook, Leanne J; Marotti, Jonathan D; Tsongalis, Gregory J
2014-08-01
HER2 fluorescence in-situ hybridization (FISH) is used in breast and gastro-esophageal carcinoma for determining HER2 gene amplification and patients' eligibility for HER2 targeted therapeutics. Traditional manual processing of the FISH slides is labor intensive because of multiple steps that require hands on manipulation of the slides and specifically timed intervals between steps. This highly manual processing also introduces inter-run and inter-operator variability that may affect the quality of the FISH result. Therefore, we sought to incorporate an automated processing instrument into our FISH workflow. Twenty-six cases including breast (20) and gastro-esophageal (6) cancer comprising 23 biopsies and three excision specimens were tested for HER2 FISH (Pathvysion, Abbott) using the Thermobrite Elite (TBE) system (Leica). Up to 12 slides can be run simultaneously. All cases were previously tested by the Pathvysion HER2 FISH assay with manual preparation. Twenty cells were counted by two observers for each case; five cases were tested on three separate runs by different operators to evaluate the precision and inter-operator variability. There was 100% concordance in the scoring between the manual and TBE methods as well as among the five cases that were tested on three runs. Only one case failed due to poor probe hybridization. In total, seven cases were positive for HER2 amplification (HER2:CEP17 ratio >2.2) and the remaining 19 were negative (HER2:CEP17 ratio <1.8) utilizing the 2007 ASCO/CAP scoring criteria. Due to the automated denaturation and hybridization, for each run, there was a reduction in labor of 3.5h which could then be dedicated to other lab functions. The TBE is a walk away pre- and post-hybridization system that automates FISH slide processing, improves work flow and consistency and saves approximately 3.5h of technologist time. The instrument has a small footprint thus occupying minimal counter space. TBE processed slides performed exceptionally well in comparison to the manual technique with no disagreement in HER2 amplification status. Copyright © 2014 Elsevier Inc. All rights reserved.
Jordan, Jeanne A; Ibe, Christine O; Moore, Miranda S; Host, Christel; Simon, Gary L
2012-05-01
In resource-limited settings (RLS) dried blood spots (DBS) are collected on infants and transported through provincial laboratories to a central facility where HIV-1 DNA PCR testing is performed using specialized equipment. Implementing a simpler approach not requiring such equipment or skilled personnel could allow the more numerous provincial laboratories to offer testing, improving turn-around-time to identify and treat infected infants sooner. Assess performances of a manual DNA extraction method and helicase-dependent amplification (HDA) assay for detecting HIV-1 DNA from DBS. 60 HIV-1 infected adults were enrolled, blood samples taken and DBS made. DBS extracts were assessed for DNA concentration and beta globin amplification using PCR and melt-curve analysis. These same extracts were then tested for HIV-1 DNA using HDA and compared to results generated by PCR and pyrosequencing. Finally, HDA limit of detection (LOD) studies were performed using DBS extracts prepared with known numbers of 8E5 cells. The manual extraction protocol consistently yielded high concentrations of amplifiable DNA from DBS. LOD assessment demonstrated HDA detected ∼470 copies/ml of HIV-1 DNA extracts in 4/4 replicates. No statistical difference was found using the McNemar's test when comparing HDA to PCR for detecting HIV-1 DNA from DBS. Using just a magnet, heat block and pipettes, the manual extraction protocol and HDA assay detected HIV-1 DNA from DBS at levels that would be useful for early infant diagnosis. Next steps will include assessing HDA for non-B HIV-1 subtypes recognition and comparison to Roche HIV-1 DNA v1.5 PCR assay. Copyright © 2012 Elsevier B.V. All rights reserved.
Comparison of Inoculation with the InoqulA and WASP Automated Systems with Manual Inoculation
Croxatto, Antony; Dijkstra, Klaas; Prod'hom, Guy
2015-01-01
The quality of sample inoculation is critical for achieving an optimal yield of discrete colonies in both monomicrobial and polymicrobial samples to perform identification and antibiotic susceptibility testing. Consequently, we compared the performance between the InoqulA (BD Kiestra), the WASP (Copan), and manual inoculation methods. Defined mono- and polymicrobial samples of 4 bacterial species and cloudy urine specimens were inoculated on chromogenic agar by the InoqulA, the WASP, and manual methods. Images taken with ImagA (BD Kiestra) were analyzed with the VisionLab version 3.43 image analysis software to assess the quality of growth and to prevent subjective interpretation of the data. A 3- to 10-fold higher yield of discrete colonies was observed following automated inoculation with both the InoqulA and WASP systems than that with manual inoculation. The difference in performance between automated and manual inoculation was mainly observed at concentrations of >106 bacteria/ml. Inoculation with the InoqulA system allowed us to obtain significantly more discrete colonies than the WASP system at concentrations of >107 bacteria/ml. However, the level of difference observed was bacterial species dependent. Discrete colonies of bacteria present in 100- to 1,000-fold lower concentrations than the most concentrated populations in defined polymicrobial samples were not reproducibly recovered, even with the automated systems. The analysis of cloudy urine specimens showed that InoqulA inoculation provided a statistically significantly higher number of discrete colonies than that with WASP and manual inoculation. Consequently, the automated InoqulA inoculation greatly decreased the requirement for bacterial subculture and thus resulted in a significant reduction in the time to results, laboratory workload, and laboratory costs. PMID:25972424
NASA Technical Reports Server (NTRS)
Montgomery, O. L.
1977-01-01
Procedures developed for digitizing the transportation arteries, airports, and dock facilities of Alabama and placing them in a computerized format compatible with the Alabama Resource Information System are described. The time required to digitize by the following methods: (a) manual, (b) Telereadex 29 with film reading and digitizing system, and (c) digitizing tablets was evaluated. A method for digitizing and storing information from the U. T. M. grid cell base which was compatible with the system was developed and tested. The highways, navigable waterways, railroads, airports, and docks in the study area were digitized and the data stored. The manual method of digitizing was shown to be best for small amounts of data, while the graphic input from the digitizing tablets would be the best approach for entering the large amounts of data required for an entire state.
Unsupervised Ensemble Anomaly Detection Using Time-Periodic Packet Sampling
NASA Astrophysics Data System (ADS)
Uchida, Masato; Nawata, Shuichi; Gu, Yu; Tsuru, Masato; Oie, Yuji
We propose an anomaly detection method for finding patterns in network traffic that do not conform to legitimate (i.e., normal) behavior. The proposed method trains a baseline model describing the normal behavior of network traffic without using manually labeled traffic data. The trained baseline model is used as the basis for comparison with the audit network traffic. This anomaly detection works in an unsupervised manner through the use of time-periodic packet sampling, which is used in a manner that differs from its intended purpose — the lossy nature of packet sampling is used to extract normal packets from the unlabeled original traffic data. Evaluation using actual traffic traces showed that the proposed method has false positive and false negative rates in the detection of anomalies regarding TCP SYN packets comparable to those of a conventional method that uses manually labeled traffic data to train the baseline model. Performance variation due to the probabilistic nature of sampled traffic data is mitigated by using ensemble anomaly detection that collectively exploits multiple baseline models in parallel. Alarm sensitivity is adjusted for the intended use by using maximum- and minimum-based anomaly detection that effectively take advantage of the performance variations among the multiple baseline models. Testing using actual traffic traces showed that the proposed anomaly detection method performs as well as one using manually labeled traffic data and better than one using randomly sampled (unlabeled) traffic data.
Training manuals for nondestructive testing using magnetic particles
NASA Technical Reports Server (NTRS)
1968-01-01
Training manuals containing the fundamentals of nondestructive testing using magnetic particle as detection media are used by metal parts inspectors and quality assurance specialists. Magnetic particle testing involves magnetization of the test specimen, application of the magnetic particle and interpretation of the patterns formed.
49 CFR 383.131 - Test manuals.
Code of Federal Regulations, 2012 CFR
2012-10-01
...; (ix) Causes for automatic failure of skills tests; (x) Standardized scoring sheets for the skills tests; and (xi) Standardized driving instructions for the applicants. (2) A State may include any... 49 Transportation 5 2012-10-01 2012-10-01 false Test manuals. 383.131 Section 383.131...
Letters, S; Smith, A J; McHugh, S; Bagg, J
2005-10-22
This study examined methods used for reprocessing endodontic instruments in general dental practice and determined the degree of residual visual contamination and blood contamination on 250 reprocessed files collected from 25 general dental practices. A questionnaire was administered to 25 general dental practitioners to obtain information on the re-processing of used endodontic files. Ten files which had been used and reprocessed were also collected from each practice. These were examined visually under a dissecting light microscope for residual contamination and then tested for blood deposits using the Kastle-Meyer test. Nineteen of the 25 practices used stainless steel hand files. No practitioners used endodontic files as single use devices. Ninety-two per cent of the practitioners discarded and replaced files when they were bent or damaged. Several decontamination methods were reported. The two combinations employed most frequently were manual cleaning and autoclaving or manual cleaning, followed by ultrasonic cleaning and autoclaving. Of the 250 files, 75% showed some degree of visual contamination and seven percent tested positive for residual blood. Blood contaminated files were significantly more heavily contaminated when examined visually. Large variations were found in residual contamination of files collected from practices using the same methods of decontamination. While all practitioners re-used endodontic files, the variations in decontamination methods reported indicate a lack of clarity on best practice. This study demonstrates that endodontic files are not reliably decontaminated by methods currently employed in dental practice.
Zhen, Chen; QuiuLi, Zhang; YuanQi, An; Casado, Verónica Vocero; Fan, Yuan
2016-01-01
Currently, conventional enzyme immunoassays which use manual gold immunoassays and colloidal tests (GICTs) are used as screening tools to detect Treponema pallidum (syphilis), hepatitis B virus (HBV), hepatitis C virus (HCV), human immunodeficiency virus type 1 (HIV-1), and HIV-2 in patients undergoing surgery. The present observational, cross-sectional study compared the sensitivity, specificity, and work flow characteristics of the conventional algorithm with manual GICTs with those of a newly proposed algorithm that uses the automated Bio-Flash technology as a screening tool in patients undergoing gastrointestinal (GI) endoscopy. A total of 956 patients were examined for the presence of serological markers of infection with HIV-1/2, HCV, HBV, and T. pallidum. The proposed algorithm with the Bio-Flash technology was superior for the detection of all markers (100.0% sensitivity and specificity for detection of anti-HIV and anti-HCV antibodies, HBV surface antigen [HBsAg], and T. pallidum) compared with the conventional algorithm based on the manual method (80.0% sensitivity and 98.6% specificity for the detection of anti-HIV, 75.0% sensitivity for the detection of anti-HCV, 94.7% sensitivity for the detection of HBsAg, and 100% specificity for the detection of anti-HCV and HBsAg) in these patients. The automated Bio-Flash technology-based screening algorithm also reduced the operation time by 85.0% (205 min) per day, saving up to 24 h/week. In conclusion, the use of the newly proposed screening algorithm based on the automated Bio-Flash technology can provide an advantage over the use of conventional algorithms based on manual methods for screening for HIV, HBV, HCV, and syphilis before GI endoscopy. PMID:27707942
Jun, Zhou; Zhen, Chen; QuiuLi, Zhang; YuanQi, An; Casado, Verónica Vocero; Fan, Yuan
2016-12-01
Currently, conventional enzyme immunoassays which use manual gold immunoassays and colloidal tests (GICTs) are used as screening tools to detect Treponema pallidum (syphilis), hepatitis B virus (HBV), hepatitis C virus (HCV), human immunodeficiency virus type 1 (HIV-1), and HIV-2 in patients undergoing surgery. The present observational, cross-sectional study compared the sensitivity, specificity, and work flow characteristics of the conventional algorithm with manual GICTs with those of a newly proposed algorithm that uses the automated Bio-Flash technology as a screening tool in patients undergoing gastrointestinal (GI) endoscopy. A total of 956 patients were examined for the presence of serological markers of infection with HIV-1/2, HCV, HBV, and T. pallidum The proposed algorithm with the Bio-Flash technology was superior for the detection of all markers (100.0% sensitivity and specificity for detection of anti-HIV and anti-HCV antibodies, HBV surface antigen [HBsAg], and T. pallidum) compared with the conventional algorithm based on the manual method (80.0% sensitivity and 98.6% specificity for the detection of anti-HIV, 75.0% sensitivity for the detection of anti-HCV, 94.7% sensitivity for the detection of HBsAg, and 100% specificity for the detection of anti-HCV and HBsAg) in these patients. The automated Bio-Flash technology-based screening algorithm also reduced the operation time by 85.0% (205 min) per day, saving up to 24 h/week. In conclusion, the use of the newly proposed screening algorithm based on the automated Bio-Flash technology can provide an advantage over the use of conventional algorithms based on manual methods for screening for HIV, HBV, HCV, and syphilis before GI endoscopy. Copyright © 2016 Jun et al.
Automated touch sensing in the mouse tapered beam test using Raspberry Pi.
Ardesch, Dirk Jan; Balbi, Matilde; Murphy, Timothy H
2017-11-01
Rodent models of neurological disease such as stroke are often characterized by motor deficits. One of the tests that are used to assess these motor deficits is the tapered beam test, which provides a sensitive measure of bilateral motor function based on foot faults (slips) made by a rodent traversing a gradually narrowing beam. However, manual frame-by-frame scoring of video recordings is necessary to obtain test results, which is time-consuming and prone to human rater bias. We present a cost-effective method for automated touch sensing in the tapered beam test. Capacitive touch sensors detect foot faults onto the beam through a layer of conductive paint, and results are processed and stored on a Raspberry Pi computer. Automated touch sensing using this method achieved high sensitivity (96.2%) as compared to 'gold standard' manual video scoring. Furthermore, it provided a reliable measure of lateralized motor deficits in mice with unilateral photothrombotic stroke: results indicated an increased number of contralesional foot faults for up to 6days after ischemia. The automated adaptation of the tapered beam test produces results immediately after each trial, without the need for labor-intensive post-hoc video scoring. It also increases objectivity of the data as it requires less experimenter involvement during analysis. Automated touch sensing may provide a useful adaptation to the existing tapered beam test in mice, while the simplicity of the hardware lends itself to potential further adaptations to related behavioral tests. Copyright © 2017 Elsevier B.V. All rights reserved.
NASA Technical Reports Server (NTRS)
Hazen-Bosveld, April; Lipert, Robert J.; Nordling, John; Shih, Chien-Ju; Siperko, Lorraine; Porter, Marc D.; Gazda, Daniel B.; Rutz, Jeff A.; Straub, John E.; Schultz, John R.;
2007-01-01
Colorimetric-solid phase extraction (C-SPE) is being developed as a method for in-flight monitoring of spacecraft water quality. C-SPE is based on measuring the change in the diffuse reflectance spectrum of indicator disks following exposure to a water sample. Previous microgravity testing has shown that air bubbles suspended in water samples can cause uncertainty in the volume of liquid passed through the disks, leading to errors in the determination of water quality parameter concentrations. We report here the results of a recent series of C-9 microgravity experiments designed to evaluate manual manipulation as a means to collect bubble-free water samples of specified volumes from water sample bags containing up to 47% air. The effectiveness of manual manipulation was verified by comparing the results from C-SPE analyses of silver(I) and iodine performed in-flight using samples collected and debubbled in microgravity to those performed on-ground using bubble-free samples. The ground and flight results showed excellent agreement, demonstrating that manual manipulation is an effective means for collecting bubble-free water samples in microgravity.
STOP using just GO: a multi-ontology hypothesis generation tool for high throughput experimentation
2013-01-01
Background Gene Ontology (GO) enrichment analysis remains one of the most common methods for hypothesis generation from high throughput datasets. However, we believe that researchers strive to test other hypotheses that fall outside of GO. Here, we developed and evaluated a tool for hypothesis generation from gene or protein lists using ontological concepts present in manually curated text that describes those genes and proteins. Results As a consequence we have developed the method Statistical Tracking of Ontological Phrases (STOP) that expands the realm of testable hypotheses in gene set enrichment analyses by integrating automated annotations of genes to terms from over 200 biomedical ontologies. While not as precise as manually curated terms, we find that the additional enriched concepts have value when coupled with traditional enrichment analyses using curated terms. Conclusion Multiple ontologies have been developed for gene and protein annotation, by using a dataset of both manually curated GO terms and automatically recognized concepts from curated text we can expand the realm of hypotheses that can be discovered. The web application STOP is available at http://mooneygroup.org/stop/. PMID:23409969
[The Confusion Assessment Method: Transcultural adaptation of a French version].
Antoine, V; Belmin, J; Blain, H; Bonin-Guillaume, S; Goldsmith, L; Guerin, O; Kergoat, M-J; Landais, P; Mahmoudi, R; Morais, J A; Rataboul, P; Saber, A; Sirvain, S; Wolfklein, G; de Wazieres, B
2018-05-01
The Confusion Assessment Method (CAM) is a validated key tool in clinical practice and research programs to diagnose delirium and assess its severity. There is no validated French version of the CAM training manual and coding guide (Inouye SK). The aim of this study was to establish a consensual French version of the CAM and its manual. Cross-cultural adaptation to achieve equivalence between the original version and a French adapted version of the CAM manual. A rigorous process was conducted including control of cultural adequacy of the tool's components, double forward and back translations, reconciliation, expert committee review (including bilingual translators with different nationalities, a linguist, highly qualified clinicians, methodologists) and pretesting. A consensual French version of the CAM was achieved. Implementation of the CAM French version in daily clinical practice will enable optimal diagnosis of delirium diagnosis and enhance communication between health professionals in French speaking countries. Validity and psychometric properties are being tested in a French multicenter cohort, opening up new perspectives for improved quality of care and research programs in French speaking countries. Copyright © 2018 Elsevier Masson SAS. All rights reserved.
Operator's Manual for Waveform Generator Model RPG-6236-A
DOT National Transportation Integrated Search
1988-02-01
The waveform generator, described in this manual, provides a reference signal standard for use in testing the performance of crash test data acquisition systems. During the test, the waveform generator provides the signal inputs to the data acquisiti...
DOE Office of Scientific and Technical Information (OSTI.GOV)
Orendorff, Christopher; Lamb, Joshua; Steele, Leigh Anna Marie
This report describes recommended abuse testing procedures for rechargeable energy storage systems (RESSs) for electric vehicles. This report serves as a revision to the FreedomCAR Electrical Energy Storage System Abuse Test Manual for Electric and Hybrid Electric Vehicle Applications (SAND2005-3123).
Video Measurements: Quantity or Quality
ERIC Educational Resources Information Center
Zajkov, Oliver; Mitrevski, Boce
2012-01-01
Students have problems with understanding, using and interpreting graphs. In order to improve the students' skills for working with graphs, we propose Manual Video Measurement (MVM). In this paper, the MVM method is explained and its accuracy is tested. The comparison with the standardized video data software shows that its accuracy is comparable…
Radar Cuts Subsoil Survey Costs
NASA Technical Reports Server (NTRS)
Johnson, R.; Glaccum, R.
1984-01-01
Soil features located with minimum time and labor. Ground-penetrating radar (GPR) system supplements manual and mechanical methods in performing subsurface soil survey. Mobile system obtains graphic profile of soil discontinuities and interfaces as function of depth. One or two test borings necessary to substantiate soil profile. GPR proves useful as reconnaissance tool.
User's Manual for the Basic Math Mastery Tests.
ERIC Educational Resources Information Center
Weiss, David J.; Trombley, Robert J.
This user manual introduces and explains the Basic Math Mastery Tests (BMMT), a collection of 10 tests of specific mathematics skills. The tests were designed to assess mastery of specific skills required for successful performance in vocational education or in occupations requiring mathematics skills. All 10 tests are administered and scored by…
Automating testbed documentation and database access using World Wide Web (WWW) tools
NASA Technical Reports Server (NTRS)
Ames, Charles; Auernheimer, Brent; Lee, Young H.
1994-01-01
A method for providing uniform transparent access to disparate distributed information systems was demonstrated. A prototype testing interface was developed to access documentation and information using publicly available hypermedia tools. The prototype gives testers a uniform, platform-independent user interface to on-line documentation, user manuals, and mission-specific test and operations data. Mosaic was the common user interface, and HTML (Hypertext Markup Language) provided hypertext capability.
Ciesla, Nancy; Dinglas, Victor; Fan, Eddy; Kho, Michelle; Kuramoto, Jill; Needham, Dale
2011-04-12
Survivors of acute respiratory distress syndrome (ARDS) and other causes of critical illness often have generalized weakness, reduced exercise tolerance, and persistent nerve and muscle impairments after hospital discharge. Using an explicit protocol with a structured approach to training and quality assurance of research staff, manual muscle testing (MMT) is a highly reliable method for assessing strength, using a standardized clinical examination, for patients following ARDS, and can be completed with mechanically ventilated patients who can tolerate sitting upright in bed and are able to follow two-step commands. (7, 8) This video demonstrates a protocol for MMT, which has been taught to ≥ 43 research staff who have performed >800 assessments on >280 ARDS survivors. Modifications for the bedridden patient are included. Each muscle is tested with specific techniques for positioning, stabilization, resistance, and palpation for each score of the 6-point ordinal Medical Research Council scale. Three upper and three lower extremity muscles are graded in this protocol: shoulder abduction, elbow flexion, wrist extension, hip flexion, knee extension, and ankle dorsiflexion. These muscles were chosen based on the standard approach for evaluating patients for ICU-acquired weakness used in prior publications. (1,2).
A mobile work station concept for mechanically aided astronaut assembly of large space trusses
NASA Technical Reports Server (NTRS)
Heard, W. L., Jr.; Bush, H. G.; Wallson, R. E.; Jensen, J. K.
1983-01-01
This report presents results of a series of truss assembly tests conducted to evaluate a mobile work station concept intended to mechanically assist astronaut manual assembly of erectable space trusses. The tests involved assembly of a tetrahedral truss beam by a pair of test subjects with and without pressure (space) suits, both in Earth gravity and in simulated zero gravity (neutral buoyancy in water). The beam was assembled from 38 identical graphite-epoxy nestable struts, 5.4 m in length with aluminum quick-attachment structural joints. Struts and joints were designed to closely simulate flight hardware. The assembled beam was approximately 16.5 m long and 4.5 m on each of the four sides of its diamond-shaped cross section. The results show that average in-space assembly rates of approximately 38 seconds per strut can be expected for struts of comparable size. This result is virtually independent of the overall size of the structure being assembled. The mobile work station concept would improve astronaut efficiency for on-orbit manual assembly of truss structures, and also this assembly-line method is highly competitive with other construction methods being considered for large space structures.
Lee, Sungsil; Lim, Hwan Sub; Park, Jungyong; Kim, Hyon Suk
2009-04-01
In the diagnosis of atopic diseases, allergen detection is a crucial step. Multiple allergen simultaneous test-chemiluminescent assay (MAST-CLA) is a simple and noninvasive method for in vitro screening of allergen-specific IgE antibodies. The Korean Inhalant Panel test on 20 patients and Food Panel test on 19 patients were performed using the conventional manual MAST-CLA kit and the new automated MAST-CLA method (automated AP720S system for the Optigen Assay; Hitachi Chemical Diagnostics, Inc., USA) simultaneously. The results were evaluated for positive reactivity and concordance. The results of inhalant panel gave a relatively higher class level result than the food panel. The 8 patients out of 20 (40%) of the inhalation panel, and 9 patients out of 18 (47.4%) of the food panel showed 100% concordance between the 2 systems. Eighteen patients (90%) of the Inhalation Panel and sixteen patients (84.2%) of the Food Panel showed more than 91% concordance. These results suggest that the MAST-CLA assay using the new, automated AP720S analyzer performs well, showing a high concordance rate with conventional MAST-CLA. Compared to manual MAST-CLA, the automated AP720S system has a shorter assay time and uses a smaller serum volume (500 microl) along with other conveniences.
Semi-automating the manual literature search for systematic reviews increases efficiency.
Chapman, Andrea L; Morgan, Laura C; Gartlehner, Gerald
2010-03-01
To minimise retrieval bias, manual literature searches are a key part of the search process of any systematic review. Considering the need to have accurate information, valid results of the manual literature search are essential to ensure scientific standards; likewise efficient approaches that minimise the amount of personnel time required to conduct a manual literature search are of great interest. The objective of this project was to determine the validity and efficiency of a new manual search method that utilises the scopus database. We used the traditional manual search approach as the gold standard to determine the validity and efficiency of the proposed scopus method. Outcome measures included completeness of article detection and personnel time involved. Using both methods independently, we compared the results based on accuracy of the results, validity and time spent conducting the search, efficiency. Regarding accuracy, the scopus method identified the same studies as the traditional approach indicating its validity. In terms of efficiency, using scopus led to a time saving of 62.5% compared with the traditional approach (3 h versus 8 h). The scopus method can significantly improve the efficiency of manual searches and thus of systematic reviews.
ERIC Educational Resources Information Center
Cronin, Mary C.; And Others
This document (two manuals combined) offers a practical, straightforward means of evaluating the reading level of students in French immersion classes at the elementary level. The evaluator's manual features a good review of the relevant publications in the field and provides clear, detailed descriptions of each of three reading levels, the…
14 CFR 33.87 - Endurance test.
Code of Federal Regulations, 2011 CFR
2011-01-01
... particular engine being tested. (2) Any automatic engine control that is part of the engine must control the engine during the endurance test except for operations where automatic control is normally overridden by manual control or where manual control is otherwise specified for a particular test run. (3) Except as...
14 CFR 33.87 - Endurance test.
Code of Federal Regulations, 2012 CFR
2012-01-01
... particular engine being tested. (2) Any automatic engine control that is part of the engine must control the engine during the endurance test except for operations where automatic control is normally overridden by manual control or where manual control is otherwise specified for a particular test run. (3) Except as...
Gil-Agudo, Ángel; Solís-Mozos, Marta; Crespo-Ruiz, Beatriz; Del-Ama Eng, Antonio J; Pérez-Rizo, Enrique; Segura-Fragoso, Antonio; Jiménez-Díaz, Fernando
2014-01-01
Manual wheelchair users with spinal cord injury (SCI) have a high prevalence of shoulder pain due to the use of the upper extremity for independent mobility, transfers, and other activities of daily living. Indeed, shoulder pain dramatically affects quality of life of these individuals. There is limited evidence obtained through radiographic techniques of a relationship between the forces acting on the shoulder during different propulsion conditions and shoulder pathologies. Today, ultrasound is widely accepted as a precise tool in diagnosis, displaying particularly effectiveness in screening the shoulder rotator cuff. Thus, we set out to perform an ultrasound-based study of the acute changes to the shoulder soft tissues after propelling a manual wheelchair in two workload settings. Shoulder joint kinetics was recorded from 14 manual wheelchair users with SCI while they performed high- and low-intensity wheelchair propulsion tests (constant and incremental). Shoulder joint forces and moments were obtained from inverse dynamic methods, and ultrasound screening of the shoulder was performed before and immediately after the test. Kinetic changes were more relevant after the most intensive task, showing the significance of high-intensity activity, yet no differences were found in ultrasound-related parameters before and after each propulsion task. It therefore appears that further studies will be needed to collect clinical data and correlate data regarding shoulder pain with both ultrasound images and data from shoulder kinetics.
Gil-Agudo, Ángel; Solís-Mozos, Marta; Crespo-Ruiz, Beatriz; del-Ama Eng, Antonio J.; Pérez-Rizo, Enrique; Segura-Fragoso, Antonio; Jiménez-Díaz, Fernando
2014-01-01
Manual wheelchair users with spinal cord injury (SCI) have a high prevalence of shoulder pain due to the use of the upper extremity for independent mobility, transfers, and other activities of daily living. Indeed, shoulder pain dramatically affects quality of life of these individuals. There is limited evidence obtained through radiographic techniques of a relationship between the forces acting on the shoulder during different propulsion conditions and shoulder pathologies. Today, ultrasound is widely accepted as a precise tool in diagnosis, displaying particularly effectiveness in screening the shoulder rotator cuff. Thus, we set out to perform an ultrasound-based study of the acute changes to the shoulder soft tissues after propelling a manual wheelchair in two workload settings. Shoulder joint kinetics was recorded from 14 manual wheelchair users with SCI while they performed high- and low-intensity wheelchair propulsion tests (constant and incremental). Shoulder joint forces and moments were obtained from inverse dynamic methods, and ultrasound screening of the shoulder was performed before and immediately after the test. Kinetic changes were more relevant after the most intensive task, showing the significance of high-intensity activity, yet no differences were found in ultrasound-related parameters before and after each propulsion task. It therefore appears that further studies will be needed to collect clinical data and correlate data regarding shoulder pain with both ultrasound images and data from shoulder kinetics. PMID:25566539
Evaluation of DuPont Qualicon Bax System PCR assay for yeast and mold.
Wallace, F Morgan; Burns, Frank; Fleck, Lois; Andaloro, Bridget; Farnum, Andrew; Tice, George; Ruebl, Joanne
2010-01-01
Evaluations were conducted to test the performance of the BAX System PCR assay which was certified as Performance Tested Method 010902 for screening yeast and mold in yogurt, corn starch, and milk-based powdered infant formula. Method comparison studies performed on samples with low-level inoculates showed that the BAX System demonstrates a sensitivity equivalent to the U.S. Food and Drug Administration's Bacteriological Analytical Manual culture method, but with a significantly shorter time to obtain results. Tests to evaluate inclusivity and exclusivity returned no false-negative and no false-positive results on a diverse panel of isolates, and tests for lot-to-lot variability and tablet stability demonstrated consistent performance. Ruggedness studies determined that none of the factors examined affected the performance of the assay.
CometBoards Users Manual Release 1.0
NASA Technical Reports Server (NTRS)
Guptill, James D.; Coroneos, Rula M.; Patnaik, Surya N.; Hopkins, Dale A.; Berke, Lazlo
1996-01-01
Several nonlinear mathematical programming algorithms for structural design applications are available at present. These include the sequence of unconstrained minimizations technique, the method of feasible directions, and the sequential quadratic programming technique. The optimality criteria technique and the fully utilized design concept are two other structural design methods. A project was undertaken to bring all these design methods under a common computer environment so that a designer can select any one of these tools that may be suitable for his/her application. To facilitate selection of a design algorithm, to validate and check out the computer code, and to ascertain the relative merits of the design tools, modest finite element structural analysis programs based on the concept of stiffness and integrated force methods have been coupled to each design method. The code that contains both these design and analysis tools, by reading input information from analysis and design data files, can cast the design of a structure as a minimum-weight optimization problem. The code can then solve it with a user-specified optimization technique and a user-specified analysis method. This design code is called CometBoards, which is an acronym for Comparative Evaluation Test Bed of Optimization and Analysis Routines for the Design of Structures. This manual describes for the user a step-by-step procedure for setting up the input data files and executing CometBoards to solve a structural design problem. The manual includes the organization of CometBoards; instructions for preparing input data files; the procedure for submitting a problem; illustrative examples; and several demonstration problems. A set of 29 structural design problems have been solved by using all the optimization methods available in CometBoards. A summary of the optimum results obtained for these problems is appended to this users manual. CometBoards, at present, is available for Posix-based Cray and Convex computers, Iris and Sun workstations, and the VM/CMS system.
Jungkind, D
2001-01-01
While it is an extremely powerful and versatile assay method, polymerase chain reaction (PCR) can be a labor-intensive process. Since the advent of commercial test kits from Roche and the semi-automated microwell Amplicor system, PCR has become an increasingly useful and widespread clinical tool. However, more widespread acceptance of molecular testing will depend upon automation that allows molecular assays to enter the routine clinical laboratory. The forces driving the need for automated PCR are the requirements for diagnosis and treatment of chronic viral diseases, economic pressures to develop more automated and less expensive test procedures similar to those in the clinical chemistry laboratories, and a shortage in many areas of qualified laboratory personnel trained in the types of manual procedures used in past decades. The automated Roche COBAS AMPLICOR system has automated the amplification and detection process. Specimen preparation remains the most labor-intensive part of the PCR testing process, accounting for the majority of the hands-on-time in most of the assays. A new automated specimen preparation system, the COBAS AmpliPrep, was evaluated. The system automatically releases the target nucleic acid, captures the target with specific oligonucleotide probes, which become attached to magnetic beads via a biotin-streptavidin binding reaction. Once attached to the beads, the target is purified and concentrated automatically. Results of 298 qualitative and 57 quantitative samples representing a wide range of virus concentrations analyzed after the COBAS AmpliPrep and manual specimen preparation methods, showed that there was no significant difference in qualitative or quantitative hepatitis C virus (HCV) assay performance, respectively. The AmpliPrep instrument decreased the time required to prepare serum or plasma samples for HCV PCR to under 1 min per sample. This was a decrease of 76% compared to the manual specimen preparation method. Systems that can analyze more samples with higher throughput and that can answer more questions about the nature of the microbes that we can presently only detect and quantitate will be needed in the future.
Design manual: Oxygen Thermal Test Article (OTTA)
NASA Technical Reports Server (NTRS)
Chronic, W. L.; Baese, C. L.; Conder, R. L.
1974-01-01
The characteristics of a cryogenic tank for storing liquid hydrogen, nitrogen, oxygen, methane, or helium for an extended period of time with minimum losses are discussed. A description of the tank and control module, assembly drawings and details of major subassemblies, specific requirements controlling development of the system, thermal concept considerations, thermal analysis methods, and a record of test results are provided. The oxygen thermal test article thermal protection system has proven that the insulation system for cryogenic vessels is effective.
Computational knee ligament modeling using experimentally determined zero-load lengths.
Bloemker, Katherine H; Guess, Trent M; Maletsky, Lorin; Dodd, Kevin
2012-01-01
This study presents a subject-specific method of determining the zero-load lengths of the cruciate and collateral ligaments in computational knee modeling. Three cadaver knees were tested in a dynamic knee simulator. The cadaver knees also underwent manual envelope of motion testing to find their passive range of motion in order to determine the zero-load lengths for each ligament bundle. Computational multibody knee models were created for each knee and model kinematics were compared to experimental kinematics for a simulated walk cycle. One-dimensional non-linear spring damper elements were used to represent cruciate and collateral ligament bundles in the knee models. This study found that knee kinematics were highly sensitive to altering of the zero-load length. The results also suggest optimal methods for defining each of the ligament bundle zero-load lengths, regardless of the subject. These results verify the importance of the zero-load length when modeling the knee joint and verify that manual envelope of motion measurements can be used to determine the passive range of motion of the knee joint. It is also believed that the method described here for determining zero-load length can be used for in vitro or in vivo subject-specific computational models.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Caudell, R.B.; Bauder, M.E.; Boyer, W.B.
1993-09-01
Sandia National Laboratories (SNL) Instrumentation Development Department was tasked by the Defense Nuclear Agency (DNA) to record data on Tektronix RTD720 Digitizers on the HUNTERS TROPHY field test conducted at the Nevada Test Site (NTS) on September 18, 1992. This report contains a overview and description of the computer hardware and software that was used to acquire, reduce, and display the data. The document is divided into two volumes: an overview and operators manual (Volume 1) and a maintenance manual (Volume 2).
1989-02-28
AD-A259 245 RESEARCH TRIANGLE INSTITUTE I SOFTWARE SYSTEM USER’S MANUAL, REFERENCE MANUAL, AND INSTALLATION GUIDE FOR THE TEST ENGINEER’S ASSISTANT...SYSTEM U. yD"VxC - February 28, 1989 Iŕ 5 G3 ’Contract No. DAAL01-86-C-0039 W Prepared for: Department of the Army Electronics Research and...Development Command Fort Monmouth, New Jersey 07703 I Prepared by: Center for Digital Systems ResearchI Research Triangle Institute Research Triangle Park, NC
DOT National Transportation Integrated Search
1971-01-01
This manual describes a new method developed by the author, based on ASTM Method D2901, for determining the cement content of freshly mixed soil cement. The manual contains information on apparatus, reagents, procedures, source of equipment and reage...
A Manual of Simplified Laboratory Methods for Operators of Wastewater Treatment Facilities.
ERIC Educational Resources Information Center
Westerhold, Arnold F., Ed.; Bennett, Ernest C., Ed.
This manual is designed to provide the small wastewater treatment plant operator, as well as the new or inexperienced operator, with simplified methods for laboratory analysis of water and wastewater. It is emphasized that this manual is not a replacement for standard methods but a guide for plants with insufficient equipment to perform analyses…
NASA Technical Reports Server (NTRS)
Cassarino, S.; Sopher, R.
1982-01-01
user instruction and software descriptions for the base program of the coupled rotor/airframe vibration analysis are provided. The functional capabilities and procedures for running the program are provided. Interfaces with external programs are discussed. The procedure of synthesizing a dynamic system and the various solution methods are described. Input data and output results are presented. Detailed information is provided on the program structure. Sample test case results for five representative dynamic configurations are provided and discussed. System response are plotted to demonstrate the plots capabilities available. Instructions to install and execute SIMVIB on the CDC computer system are provided.
An automatic aerosol classification for earlinet: application and results
NASA Astrophysics Data System (ADS)
Papagiannopoulos, Nikolaos; Mona, Lucia; Amiridis, Vassilis; Binietoglou, Ioannis; D'Amico, Giuseppe; Guma-Claramunt, P.; Schwarz, Anja; Alados-Arboledas, Lucas; Amodeo, Aldo; Apituley, Arnoud; Baars, Holger; Bortoli, Daniele; Comeron, Adolfo; Guerrero-Rascado, Juan Luis; Kokkalis, Panos; Nicolae, Doina; Papayannis, Alex; Pappalardo, Gelsomina; Wandinger, Ulla; Wiegner, Matthias
2018-04-01
Aerosol typing is essential for understanding the impact of the different aerosol sources on climate, weather system and air quality. An aerosol classification method for EARLINET (European Aerosol Research Lidar Network) measurements is introduced which makes use the Mahalanobis distance classifier. The performance of the automatic classification is tested against manually classified EARLINET data. Results of the application of the method to an extensive aerosol dataset will be presented.
Mozola, Mark; Norton, Paul; Alles, Susan; Gray, R Lucas; Tolan, Jerry; Caballero, Oscar; Pinkava, Lisa; Hosking, Edan; Luplow, Karen; Rice, Jennifer
2013-01-01
ANSR Salmonella is a new molecular diagnostic assay for detection of Salmonella spp. in foods and environmental samples. The test is based on the nicking enzyme amplification reaction (NEAR) isothermal nucleic acid amplification technology. The assay platform features simple instrumentation, minimal labor, and, following a single-step 10-24 h enrichment (depending on sample type), an extremely short assay time of 30 min, including sample preparation. Detection is real-time using fluorescent molecular beacon probes. Inclusivity testing was performed using a panel of 113 strains of S. enterica and S. bongori, representing 109 serovars and all genetic subgroups. With the single exception of the rare serovar S. Weslaco, all serovars and genetic subgroups were detected. Exclusivity testing of 38 non-salmonellae, mostly Enterobacteriaceae, yielded no evidence of cross-reactivity. In comparative testing of chicken carcass rinse, raw ground turkey, raw ground beef, hot dogs, and oat cereal, there were no statistically significant differences in the number of positive results obtained with the ANSR and the U.S. Department of Agriculture-Food Safety and Inspection Service or U.S. Food and Drug Administration/Bacteriological Analytical Manual reference culture methods. In testing of swab or sponge samples from five different environmental surfaces, four trials showed no statistically significant differences in the number of positive results by the ANSR and the U.S. Food and Drug Administration/ Bacteriological Analytical Manual reference methods; in the trial with stainless steel surface, there were significantly more positive results by the ANSR method. Ruggedness experiments showed a high degree of assay robustness when deviations in reagent volumes and incubation times were introduced.
[Effect of manual cleaning and machine cleaning for dental handpiece].
Zhou, Xiaoli; Huang, Hao; He, Xiaoyan; Chen, Hui; Zhou, Xiaoying
2013-08-01
Comparing the dental handpiece' s cleaning effect between manual cleaning and machine cleaning. Eighty same contaminated dental handpieces were randomly divided into experimental group and control group, each group contains 40 pieces. The experimental group was treated by full automatic washing machine, and the control group was cleaned manually. The cleaning method was conducted according to the operations process standard, then ATP bioluminescence was used to test the cleaning results. Average relative light units (RLU) by ATP bioluminescence detection were as follows: Experimental group was 9, control group was 41. The two groups were less than the recommended RLU value provided by the instrument manufacturer (RLU < or = 45). There was significant difference between the two groups (P < 0.05). The cleaning quality of the experimental group was better than that of control group. It is recommended that the central sterile supply department should clean dental handpieces by machine to ensure the cleaning effect and maintain the quality.
Ging, Patricia B.
1999-01-01
Surface-water sampling protocols of the U.S. Geological Survey National Water-Quality Assessment (NAWQA) Program specify samples for most properties and constituents to be collected manually in equal-width increments across a stream channel and composited for analysis. Single-point sampling with an automated sampler (autosampler) during storms was proposed in the upper part of the South-Central Texas NAWQA study unit, raising the question of whether property and constituent concentrations from automatically collected samples differ significantly from those in samples collected manually. Statistical (Wilcoxon signed-rank test) analyses of 3 to 16 paired concentrations for each of 26 properties and constituents from water samples collected using both methods at eight sites in the upper part of the study unit indicated that there were no significant differences in concentrations for dissolved constituents, other than calcium and organic carbon.
49 CFR 236.1039 - Operations and Maintenance Manual.
Code of Federal Regulations, 2010 CFR
2010-10-01
... 49 Transportation 4 2010-10-01 2010-10-01 false Operations and Maintenance Manual. 236.1039... Train Control Systems § 236.1039 Operations and Maintenance Manual. (a) The railroad shall catalog and..., modification, inspection, and testing of the PTC system and have them in one Operations and Maintenance Manual...
Taylor, Stuart A; Slater, Andrew; Halligan, Steve; Honeyfield, Lesley; Roddie, Mary E; Demeshski, Jamshid; Amin, Hamdam; Burling, David
2007-01-01
To prospectively investigate the relative accuracy and reproducibility of manual and automated computer software measurements by using polyps of known size in a human colectomy specimen. Institutional review board approval was obtained for the study; written consent for use of the surgical specimen was obtained. A colectomy specimen containing 27 polyps from a 16-year-old male patient with familial adenomatous polyposis was insufflated, submerged in a container with solution, and scanned at four-section multi-detector row computed tomography (CT). A histopathologist measured the maximum dimension of all polyps in the opened specimen. Digital photographs and line drawings were produced to aid CT-histologic measurement correlation. A novice (radiographic technician) and an experienced (radiologist) observer independently estimated polyp diameter with three methods: manual two-dimensional (2D) and manual three-dimensional (3D) measurement with software calipers and automated measurement with software (automatic). Data were analyzed with paired t tests and Bland-Altman limits of agreement. Seven polyps (
Evaluation of clinical methods for peroneal muscle testing.
Sarig-Bahat, Hilla; Krasovsky, Andrei; Sprecher, Elliot
2013-03-01
Manual muscle testing of the peroneal muscles is well accepted as a testing method in musculoskeletal physiotherapy for the assessment of the foot and ankle. The peroneus longus and brevis are primary evertors and secondary plantar flexors of the ankle joint. However, some international textbooks describe them as dorsi flexors, when instructing peroneal muscle testing. The identified variability raised a question whether these educational texts are reflected in the clinical field. The purposes of this study were to investigate what are the methods commonly used in the clinical field for peroneal muscle testing and to evaluate their compatibility with functional anatomy. A cross-sectional study was conducted, using an electronic questionnaire sent to 143 Israeli physiotherapists in the musculoskeletal field. The survey questioned on the anatomical location of manual resistance and the combination of motions resisted. Ninety-seven responses were received. The majority (69%) of respondents related correctly to the peronei as evertors, but asserted that resistance should be located over the dorsal aspect of the fifth metatarsus, thereby disregarding the peroneus longus. Moreover, 38% of the respondents described the peronei as dorsi flexors, rather than plantar flexors. Only 2% selected the correct method of resisting plantarflexion and eversion at the base of the first metatarsus. We consider this technique to be the most compatible with the anatomy of the peroneus longus and brevis. The Fisher-Freeman-Halton test indicated that there was a significant relationship between responses on the questions (P = 0.0253, 95% CI 0.0249-0.0257), thus justifying further correspondence analysis. The correspondence analysis found no clustering of the answers that were compatible with anatomical evidence and were applied in the correct technique, but did demonstrate a common error, resisting dorsiflexion rather than plantarflexion, which was in agreement with the described frequencies. Inconsistencies were identified between the instruction method commonly provided for peroneal muscle testing in textbook and the functional anatomy of these muscles. Results reflect the lack of accuracy in applying functional anatomy to peroneal testing. This may be due to limited use of peroneal muscle testing or to inadequate investigation of the existing evaluation methods and their validity. Accordingly, teaching materials and clinical methods used for this test should be re-evaluated. Further research should investigate the value of peroneal muscle testing in clinical ankle evaluation. Copyright © 2012 John Wiley & Sons, Ltd.
[Automatic adjustment control system for DC glow discharge plasma source].
Wan, Zhen-zhen; Wang, Yong-qing; Li, Xiao-jia; Wang, Hai-zhou; Shi, Ning
2011-03-01
There are three important parameters in the DC glow discharge process, the discharge current, discharge voltage and argon pressure in discharge source. These parameters influence each other during glow discharge process. This paper presents an automatic control system for DC glow discharge plasma source. This system collects and controls discharge voltage automatically by adjusting discharge source pressure while the discharge current is constant in the glow discharge process. The design concept, circuit principle and control program of this automatic control system are described. The accuracy is improved by this automatic control system with the method of reducing the complex operations and manual control errors. This system enhances the control accuracy of glow discharge voltage, and reduces the time to reach discharge voltage stability. The glow discharge voltage stability test results with automatic control system are provided as well, the accuracy with automatic control system is better than 1% FS which is improved from 4% FS by manual control. Time to reach discharge voltage stability has been shortened to within 30 s by automatic control from more than 90 s by manual control. Standard samples like middle-low alloy steel and tin bronze have been tested by this automatic control system. The concentration analysis precision has been significantly improved. The RSDs of all the test result are better than 3.5%. In middle-low alloy steel standard sample, the RSD range of concentration test result of Ti, Co and Mn elements is reduced from 3.0%-4.3% by manual control to 1.7%-2.4% by automatic control, and that for S and Mo is also reduced from 5.2%-5.9% to 3.3%-3.5%. In tin bronze standard sample, the RSD range of Sn, Zn and Al elements is reduced from 2.6%-4.4% to 1.0%-2.4%, and that for Si, Ni and Fe is reduced from 6.6%-13.9% to 2.6%-3.5%. The test data is also shown in this paper.
Lee, Wonmok; Ha, Jung-Sook; Ryoo, Nam-Hee
2016-09-01
The cobas u 701, a new automated image-based urine sediment analyzer, was introduced recently. In this study, we compared its performance with that of UF-1000i flow cytometry and manual microscopy in the examination of urine sediments. Precision, linearity, and carry-over were determined for the two urine sediment analyzers. For a comparison of the method, 300 urine samples were examined by the automated analyzers and by manual microscopy using a KOVA chamber. Within-run coefficients of variation (CVs) for the control materials were 7.0-8.8% and 1.7-5.7% for the cobas u 701 and UF-1000i systems, respectively. Between-run CVs were 8.5-9.8% and 2.7-5.4%, respectively. Both instruments showed good linearity and negligible carry-over. For red blood cells (RBC), white blood cells (WBC), and epithelial cells (EPI), the overall concordance rates within one grade of difference among the three methods were good (78.6-86.0%, 88.7-93.8%, and 81.3-90.7%, respectively). The concordance rate for casts was poor (66.5-68.9%). Compared with manual microscopy, the two automated sediment analyzers tested in this study showed satisfactory analytical performances for RBC, WBC, and EPI. However, for other urine sediment particles confirmation by visual microscopy is still required. © 2016 Wiley Periodicals, Inc.
Ammari, Michelle Mikhael; Moliterno, Luiz Flávio Martins; Hirata Júnior, Raphael; Séllos, Mariana Canano; Soviero, Vera Mendes; Coutinho Filho, Wagner Pereira
2014-01-01
The aim of this study was to compare the efficacy of chemochemical methods (Carisolv™ and Papacárie®) versus the manual method (excavators) in reducing the cariogenic microbiota in dentine caries of primary teeth. Forty-six healthy children (5 to 9 years old) having at least one primary tooth with a cavitated dentine carious lesion were included in the study. The teeth presented no clinical or radiographic signs of pulpal involvement. The sample of 74 teeth was randomly divided into three different groups: Papacárie® (n = 25), Carisolv™ (n = 27) and Manual (n = 22). Samples of carious and sound dentine were collected with sterile excavators before and after caries removal in the three groups. The dentine samples were transferred to glass tubes containing a 1mL thioglycollate medium used as a carrier and enriched for microbiological detection of mutans streptococci and Lactobacillus spp, after incubation for 6h at room temperature. The minimum detection value for colony forming units (CFU) was 3.3 x 102 CFU/ml, and the results were converted into scores from 0 to 4. A significant difference was observed in relation to the microbiological scores before and after caries removal for all methods (Wilcoxon test; p < 0.001). The use of chemomechanical methods for caries removal did not improve the reduction of cariogenic microorganisms in dentine caries lesions, in comparison with manual excavation.
Oostendorp, Rob A. B.; Elvers, Hans; Mikołajewska, Emilia; Laekeman, Marjan; van Trijffel, Emiel; Samwel, Han; Duquet, William
2015-01-01
Objective. To develop and evaluate process indicators relevant to biopsychosocial history taking in patients with chronic back and neck pain. Methods. The SCEBS method, covering the Somatic, Psychological (Cognition, Emotion, and Behavior), and Social dimensions of chronic pain, was used to evaluate biopsychosocial history taking by manual physical therapists (MPTs). In Phase I, process indicators were developed while in Phase II indicators were tested in practice. Results. Literature-based recommendations were transformed into 51 process indicators. Twenty MTPs contributed 108 patient audio recordings. History taking was excellent (98.3%) for the Somatic dimension, very inadequate for Cognition (43.1%) and Behavior (38.3%), weak (27.8%) for Emotion, and low (18.2%) for the Social dimension. MTPs estimated their coverage of the Somatic dimension as excellent (100%), as adequate for Cognition, Emotion, and Behavior (60.1%), and as very inadequate for the Social dimension (39.8%). Conclusion. MTPs perform screening for musculoskeletal pain mainly through the use of somatic dimension of (chronic) pain. Psychological and social dimensions of chronic pain were inadequately covered by MPTs. Furthermore, a substantial discrepancy between actual and self-estimated use of biopsychosocial history taking was noted. We strongly recommend full implementation of the SCEBS method in educational programs in manual physical therapy. PMID:25945358
Morshed, Nader; Echols, Nathaniel; Adams, Paul D.
2015-04-25
In the process of macromolecular model building, crystallographers must examine electron density for isolated atoms and differentiate sites containing structured solvent molecules from those containing elemental ions. This task requires specific knowledge of metal-binding chemistry and scattering properties and is prone to error. A method has previously been described to identify ions based on manually chosen criteria for a number of elements. Here, the use of support vector machines (SVMs) to automatically classify isolated atoms as either solvent or one of various ions is described. Two data sets of protein crystal structures, one containing manually curated structures deposited with anomalousmore » diffraction data and another with automatically filtered, high-resolution structures, were constructed. On the manually curated data set, an SVM classifier was able to distinguish calcium from manganese, zinc, iron and nickel, as well as all five of these ions from water molecules, with a high degree of accuracy. Additionally, SVMs trained on the automatically curated set of high-resolution structures were able to successfully classify most common elemental ions in an independent validation test set. This method is readily extensible to other elemental ions and can also be used in conjunction with previous methods based on a priori expectations of the chemical environment and X-ray scattering.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Heeswijk, Miriam M. van; Department of Surgery, Maastricht University Medical Centre, Maastricht; Lambregts, Doenja M.J., E-mail: d.lambregts@nki.nl
Purpose: Diffusion-weighted imaging (DWI) tumor volumetry is promising for rectal cancer response assessment, but an important drawback is that manual per-slice tumor delineation can be highly time consuming. This study investigated whether manual DWI-volumetry can be reproduced using a (semi)automated segmentation approach. Methods and Materials: Seventy-nine patients underwent magnetic resonance imaging (MRI) that included DWI (highest b value [b1000 or b1100]) before and after chemoradiation therapy (CRT). Tumor volumes were assessed on b1000 (or b1100) DWI before and after CRT by means of (1) automated segmentation (by 2 inexperienced readers), (2) semiautomated segmentation (manual adjustment of the volumes obtained bymore » method 1 by 2 radiologists), and (3) manual segmentation (by 2 radiologists); this last assessment served as the reference standard. Intraclass correlation coefficients (ICC) and Dice similarity indices (DSI) were calculated to evaluate agreement between different methods and observers. Measurement times (from a radiologist's perspective) were recorded for each method. Results: Tumor volumes were not significantly different among the 3 methods, either before or after CRT (P=.08 to .92). ICCs compared to manual segmentation were 0.80 to 0.91 and 0.53 to 0.66 before and after CRT, respectively, for the automated segmentation and 0.91 to 0.97 and 0.61 to 0.75, respectively, for the semiautomated method. Interobserver agreement (ICC) pre and post CRT was 0.82 and 0.59 for automated segmentation, 0.91 and 0.73 for semiautomated segmentation, and 0.91 and 0.75 for manual segmentation, respectively. Mean DSI between the automated and semiautomated method were 0.83 and 0.58 pre-CRT and post-CRT, respectively; DSI between the automated and manual segmentation were 0.68 and 0.42 and 0.70 and 0.41 between the semiautomated and manual segmentation, respectively. Median measurement time for the radiologists was 0 seconds (pre- and post-CRT) for the automated method, 41 to 69 seconds (pre-CRT) and 60 to 67 seconds (post-CRT) for the semiautomated method, and 180 to 296 seconds (pre-CRT) and 84 to 91 seconds (post-CRT) for the manual method. Conclusions: DWI volumetry using a semiautomated segmentation approach is promising and a potentially time-saving alternative to manual tumor delineation, particularly for primary tumor volumetry. Once further optimized, it could be a helpful tool for tumor response assessment in rectal cancer.« less
TRENDS: A flight test relational database user's guide and reference manual
NASA Technical Reports Server (NTRS)
Bondi, M. J.; Bjorkman, W. S.; Cross, J. L.
1994-01-01
This report is designed to be a user's guide and reference manual for users intending to access rotocraft test data via TRENDS, the relational database system which was developed as a tool for the aeronautical engineer with no programming background. This report has been written to assist novice and experienced TRENDS users. TRENDS is a complete system for retrieving, searching, and analyzing both numerical and narrative data, and for displaying time history and statistical data in graphical and numerical formats. This manual provides a 'guided tour' and a 'user's guide' for the new and intermediate-skilled users. Examples for the use of each menu item within TRENDS is provided in the Menu Reference section of the manual, including full coverage for TIMEHIST, one of the key tools. This manual is written around the XV-15 Tilt Rotor database, but does include an appendix on the UH-60 Blackhawk database. This user's guide and reference manual establishes a referrable source for the research community and augments NASA TM-101025, TRENDS: The Aeronautical Post-Test, Database Management System, Jan. 1990, written by the same authors.
National Testing of Pupils in Europe: Objectives, Organisation and Use of Results. Greece 2009
ERIC Educational Resources Information Center
Eurydice, 2009
2009-01-01
Pupil assessment procedures and methods in Greece are set and "standardized" externally by the central authorities as defined in the legislative framework, the National Curriculum guidelines and teachers' manuals, while implementation is internal to the schools. The focus of primary schools is on formative assessment, while the lower…
Alexithymia as a Mediator between Childhood Trauma and Self-Injurious Behaviors
ERIC Educational Resources Information Center
Paivio, Sandra C.; McCulloch, Chantal R.
2004-01-01
Objective: The aim of this study was to test whether alexithymia mediates the relationship between childhood maltreatment and self-injurious behaviors (SIB) in college women. Method: The sample was comprised of 100 female undergraduate students. Measures were the Childhood Trauma Questionnaire [D. Bernstein, L. Fink, Manual for the Childhood…
Alford, Timothy J.; Roberts, W. Eugene; Hartsfield, James K.; Eckert, George J.; Snyder, Ronald J.
2016-01-01
Objective Utilize American Board of Orthodontics (ABO) cast/radiographic evaluation (CRE) to compare a series of 63 consecutive patients, finished with manual wire bending (conventional) treatment, vs a subsequent series of 69 consecutive patients, finished by the same orthodontist using the SureSmile™ (SS) method. Materials and Methods Records of 132 nonextraction patients were scored by a calibrated examiner blinded to treatment mode. Age and discrepancy index (DI) between groups were compared by t-tests. A chi-square test was used to compare for differences in sex and whether the patient was treated using braces only (no orthopedic correction). Analysis of covariance tested for differences in CRE outcomes and treatment times, with sex and DI included as covariates. A logarithmic transformation of CRE outcomes and treatment times was used because their distributions were skewed. Significance was defined as P < .05. Results Compared with conventional finishing, SS patients had significantly lower DI scores, less treatment time (~7 months), and better CRE scores for first-order alignment-rotation and interproximal space closure; however, second-order root angulation (RA) was inferior. Conclusion SS patients were treated in less time to better CRE scores for first-order rotation (AR) and interproximal space closure (IC) but on the average, malocclusions were less complex and second order root alignment was inferior, compared with patients finished with manual wire bending. PMID:21261488
ERIC Educational Resources Information Center
New York State Education Dept., Albany. Bureau of Elementary and Secondary Testing Programs.
This manual contains the general information on Regents Examinations, Regents Competency tests, occupational education proficiency examinations, and second language proficiency examinations, as well as the regulations and procedures for ordering, administering, and rating these examinations. The Regents Examinations are achievement tests based on…
29 CFR 1630.11 - Administration of tests.
Code of Federal Regulations, 2011 CFR
2011-07-01
... has a disability that impairs sensory, manual or speaking skills, the test results accurately reflect the skills, aptitude, or whatever other factor of the applicant or employee that the test purports to measure, rather than reflecting the impaired sensory, manual, or speaking skills of such employee or...
29 CFR 1630.11 - Administration of tests.
Code of Federal Regulations, 2010 CFR
2010-07-01
... has a disability that impairs sensory, manual or speaking skills, the test results accurately reflect the skills, aptitude, or whatever other factor of the applicant or employee that the test purports to measure, rather than reflecting the impaired sensory, manual, or speaking skills of such employee or...
ERIC Educational Resources Information Center
Johnson, Robert E.; Lavay, Barry
This manual was developed to address the need for health-related physical fitness testing of children with special needs. The first section defines the components of health-related physical fitness which consist of: (1)abdominal strength and endurance measured by a sit-up test; (2) flexibility, measured by a sit and reach test; (3) upper body…
Wu, Zhichao; Weng, Denis S D; Thenappan, Abinaya; Ritch, Robert; Hood, Donald C
2018-04-01
To evaluate a manual region-of-interest (ROI) approach for detecting progressive macular ganglion cell complex (GCC) changes on optical coherence tomography (OCT) imaging. One hundred forty-six eyes with a clinical diagnosis of glaucoma or suspected glaucoma with macular OCT scans obtained at least 1 year apart were evaluated. Changes in the GCC thickness were identified using a manual ROI approach (ROI M ), whereby region(s) of observed or suspected glaucomatous damage were manually identified when using key features from the macular OCT scan on the second visit. Progression was also evaluated using the global GCC thickness and an automatic ROI approach (ROI A ), where contiguous region(s) that fell below the 1% lower normative limit and exceeded 288 μm 2 in size were evaluated. Longitudinal signal-to-noise ratios (SNRs) were calculated for progressive changes detected by each of these methods using individualized estimates of test-retest variability and age-related changes, obtained from 303 glaucoma and 394 healthy eyes, respectively. On average, the longitudinal SNR for the global thickness, ROI A and ROI M methods were -0.90 y -1 , -0.91 y -1 , and -1.03 y -1 , respectively, and was significantly more negative for the ROI M compared with the global thickness ( P = 0.003) and ROI A methods ( P = 0.021). Progressive glaucomatous macular GCC changes were optimally detected with a manual ROI approach. These findings suggests that an approach based on a qualitative evaluation of OCT imaging information and consideration of known patterns of damage can improve the detection of progressive glaucomatous macular damage.
Improved segmentation of cerebellar structures in children
Narayanan, Priya Lakshmi; Boonazier, Natalie; Warton, Christopher; Molteno, Christopher D; Joseph, Jesuchristopher; Jacobson, Joseph L; Jacobson, Sandra W; Zöllei, Lilla; Meintjes, Ernesta M
2016-01-01
Background Consistent localization of cerebellar cortex in a standard coordinate system is important for functional studies and detection of anatomical alterations in studies of morphometry. To date, no pediatric cerebellar atlas is available. New method The probabilistic Cape Town Pediatric Cerebellar Atlas (CAPCA18) was constructed in the age-appropriate National Institute of Health Pediatric Database asymmetric template space using manual tracings of 16 cerebellar compartments in 18 healthy children (9–13 years) from Cape Town, South Africa. The individual atlases of the training subjects were also used to implement multi atlas label fusion using multi atlas majority voting (MAMV) and multi atlas generative model (MAGM) approaches. Segmentation accuracy in 14 test subjects was compared for each method to ‘gold standard’ manual tracings. Results Spatial overlap between manual tracings and CAPCA18 automated segmentation was 73% or higher for all lobules in both hemispheres, except VIIb and X. Automated segmentation using MAGM yielded the best segmentation accuracy over all lobules (mean Dice Similarity Coefficient 0.76; range 0.55–0.91). Comparison with existing methods In all lobules, spatial overlap of CAPCA18 segmentations with manual tracings was similar or higher than those obtained with SUIT (spatially unbiased infra-tentorial template), providing additional evidence of the benefits of an age appropriate atlas. MAGM segmentation accuracy was comparable to values reported recently by Park et al. (2014) in adults (across all lobules mean DSC = 0.73, range 0.40–0.89). Conclusions CAPCA18 and the associated multi atlases of the training subjects yield improved segmentation of cerebellar structures in children. PMID:26743973
Asphalt Raking. Instructor Manual. Trainee Manual.
ERIC Educational Resources Information Center
Laborers-AGC Education and Training Fund, Pomfret Center, CT.
This packet consists of the instructor and trainee manuals for an asphalt raking course. The instructor manual contains a course schedule for 4 days of instruction, content outline, and instructor outline. The trainee manual is divided into five sections: safety, asphalt basics, placing methods, repair and patching, and clean-up and maintenance.…
Automatic Scaling of Digisonde Ionograms Test and Evaluation Report.
1982-09-01
Labrador 30 21 IManual MUF - Auto MUFj/Manual MUF April 1980 Goose Bay, Labrador 31 22 IManual MUF - Auto MUFI /Manual MUF July 1980 Goose Bay...Labrador 32 23 IManual MUF - Auto MUFI /Manual MUF September 1980 Goose Bay, Labrador 33 24 !Manual M(3000) - Auto M(3000)1 January 1980 Goose Bay, Labrador
Vocational-Technical Physics Project. Instructor's Manual. Field Test Edition.
ERIC Educational Resources Information Center
Forsyth Technical Inst., Winston-Salem, NC.
This instructor's manual in vocational physics consists of five modules: Jacks, Thermometers, The Alternator, The Pool Table, and The Radiator. It is an individualized approach, designed for use with accompanying student manuals on each of the individual modules. Each module in the instructor's manual consists of a general description plus an…
Azar, Mohammad Reza; Safi, Laya; Nikaein, Afshin
2012-01-01
Background: Root canal cleaning is an important step in endodontic therapy. In order to develop better techniques, a new generation of endodontic instruments has been designed. The aim of this study was to compare the effectiveness of manual K-files (Mani Co, Tokyo, Japan) and two rotary systems–Mtwo (Dentsply-Maillefer, Ballaigues, Switzerland) and ProTaper (VDW, Munich, Germany)–for root canal preparation in primary molars. Materials and Methods: India ink was injected to 160 mesiobuccal and distal root canals of mandibular primary molars. The teeth were randomly divided into three experimental groups and one control group. In each experimental group, either manual instruments (K-files) or rotary instruments (Mtwo or ProTaper) were used to prepare root canals. After cleaning the canals and clearing the teeth, ink removal was evaluated with a stereomicroscope. Statistical analysis was done with Kruskal–Wallis and Friedman tests. Results: There were no significant differences in cleaning efficiency between manual and rotary instruments. Only ProTaper files performed significantly better in the coronal and middle thirds than in the apical third of the root canal. Conclusion: Manual K-files and the Mtwo and ProTaper rotary systems showed equally acceptable cleaning ability in primary molar root canals. PMID:22623929
Comparison of manual scaled and predicted foE and foF1 critical frequencies. Technical report
DOE Office of Scientific and Technical Information (OSTI.GOV)
Gamache, R.R.; Kersey, W.T.
1990-07-01
The CCIR and Titheridge foE critical frequency prediction routines were tested by comparison with 1875 manually scaled values. The foF1 critical frequency prediction routine of Millman et al was tested by comparison with 1005 manually scaled values. Plots and statistics of the comparisons are presented and discussed. From the results recommendations are made to help improve autoscaling.
Technology Reinvestment Project Manufacturing Education and Training. Volume 1
NASA Technical Reports Server (NTRS)
Schroer, Bernard J.; Bond, Arthur J.
1997-01-01
The manufacturing education program is a joint program between the University of Alabama in Huntsville's (UAH) College of Engineering and Alabama A&M University's (AAMLJ) School of Engineering and Technology. The objective of the program is to provide more hands-on experiences to undergraduate engineering and engineering technology students. The scope of work consisted of. Year 1, Task 1: Review courses at Alabama Industrial Development Training (AIDT); Task 2: Review courses at UAH and AAMU; Task 3: Develop new lab manuals; Task 4: Field test manuals; Task 5: Prepare annual report. Year 2, Task 1: Incorporate feedback into lab manuals; Task 2 : Introduce lab manuals into classes; Task 3: Field test manuals; Task 4: Prepare annual report. Year 3, Task 1: Incorporate feedback into lab manuals; Task 2: Introduce lab manuals into remaining classes; Task 3: Conduct evaluation with assistance of industry; Task 4: Prepare final report. This report only summarizes the activities of the University of Alabama in Huntsville. The activities of Alabama A&M University are contained in a separate report.
Code of Federal Regulations, 2010 CFR
2010-07-01
... Methods for Air Monitoring of Criteria Pollutants Pollutant Ref. or equivalent Manual or automated Applicable part 50 appendix Applicable subparts of part 53 A B C D E F SO2 Reference Manual A Equivalent Manual ✓ ✓ Automated ✓ ✓ ✓ CO Reference Automated C ✓ ✓ Equivalent Manual ✓ ✓ Automated ✓ ✓ ✓ O3...
A Manual on Nonviolence and Children.
ERIC Educational Resources Information Center
Judson, Stephanie, Comp.
This manual on teaching children non-violent attitudes and the skills for non-violent conflict resolution suggests teaching activities and methods, describes classrooms in which these methods have been employed, and explains the underlying theory of conflict resolution. The first part of the manual, an outgrowth of the Friends' Nonviolence and…
Safe Driving Knowledge Dissemination and Testing Techniques. Volume III: Handbook. Final Report.
ERIC Educational Resources Information Center
McKnight, James; Green, Molly A.
Guidelines are presented for use by driver licensing agencies in the development of driver manuals, tests, and other means of disseminating information and testing license applicants. An introductory chapter discusses the purposes of written license tests and of drivers' manuals, focusing on the needs of groups of drivers based on kind of vehicle,…
Araki, Tadashi; Kumar, P Krishna; Suri, Harman S; Ikeda, Nobutaka; Gupta, Ajay; Saba, Luca; Rajan, Jeny; Lavra, Francesco; Sharma, Aditya M; Shafique, Shoaib; Nicolaides, Andrew; Laird, John R; Suri, Jasjit S
2016-07-01
The degree of stenosis in the carotid artery can be predicted using automated carotid lumen diameter (LD) measured from B-mode ultrasound images. Systolic velocity-based methods for measurement of LD are subjective. With the advancement of high resolution imaging, image-based methods have started to emerge. However, they require robust image analysis for accurate LD measurement. This paper presents two different algorithms for automated segmentation of the lumen borders in carotid ultrasound images. Both algorithms are modeled as a two stage process. Stage one consists of a global-based model using scale-space framework for the extraction of the region of interest. This stage is common to both algorithms. Stage two is modeled using a local-based strategy that extracts the lumen interfaces. At this stage, the algorithm-1 is modeled as a region-based strategy using a classification framework, whereas the algorithm-2 is modeled as a boundary-based approach that uses the level set framework. Two sets of databases (DB), Japan DB (JDB) (202 patients, 404 images) and Hong Kong DB (HKDB) (50 patients, 300 images) were used in this study. Two trained neuroradiologists performed manual LD tracings. The mean automated LD measured was 6.35 ± 0.95 mm for JDB and 6.20 ± 1.35 mm for HKDB. The precision-of-merit was: 97.4 % and 98.0 % w.r.t to two manual tracings for JDB and 99.7 % and 97.9 % w.r.t to two manual tracings for HKDB. Statistical tests such as ANOVA, Chi-Squared, T-test, and Mann-Whitney test were conducted to show the stability and reliability of the automated techniques.
Wagner, Maximilian E H; Gellrich, Nils-Claudius; Friese, Karl-Ingo; Becker, Matthias; Wolter, Franz-Erich; Lichtenstein, Juergen T; Stoetzer, Marcus; Rana, Majeed; Essig, Harald
2016-01-01
Objective determination of the orbital volume is important in the diagnostic process and in evaluating the efficacy of medical and/or surgical treatment of orbital diseases. Tools designed to measure orbital volume with computed tomography (CT) often cannot be used with cone beam CT (CBCT) because of inferior tissue representation, although CBCT has the benefit of greater availability and lower patient radiation exposure. Therefore, a model-based segmentation technique is presented as a new method for measuring orbital volume and compared to alternative techniques. Both eyes from thirty subjects with no known orbital pathology who had undergone CBCT as a part of routine care were evaluated (n = 60 eyes). Orbital volume was measured with manual, atlas-based, and model-based segmentation methods. Volume measurements, volume determination time, and usability were compared between the three methods. Differences in means were tested for statistical significance using two-tailed Student's t tests. Neither atlas-based (26.63 ± 3.15 mm(3)) nor model-based (26.87 ± 2.99 mm(3)) measurements were significantly different from manual volume measurements (26.65 ± 4.0 mm(3)). However, the time required to determine orbital volume was significantly longer for manual measurements (10.24 ± 1.21 min) than for atlas-based (6.96 ± 2.62 min, p < 0.001) or model-based (5.73 ± 1.12 min, p < 0.001) measurements. All three orbital volume measurement methods examined can accurately measure orbital volume, although atlas-based and model-based methods seem to be more user-friendly and less time-consuming. The new model-based technique achieves fully automated segmentation results, whereas all atlas-based segmentations at least required manipulations to the anterior closing. Additionally, model-based segmentation can provide reliable orbital volume measurements when CT image quality is poor.
Liu, Peiying; Lu, Hanzhang; Filbey, Francesca M.; Pinkham, Amy E.; McAdams, Carrie J.; Adinoff, Bryon; Daliparthi, Vamsi; Cao, Yan
2014-01-01
Phase-Contrast MRI (PC-MRI) is a noninvasive technique to measure blood flow. In particular, global but highly quantitative cerebral blood flow (CBF) measurement using PC-MRI complements several other CBF mapping methods such as arterial spin labeling and dynamic susceptibility contrast MRI by providing a calibration factor. The ability to estimate blood supply in physiological units also lays a foundation for assessment of brain metabolic rate. However, a major obstacle before wider applications of this method is that the slice positioning of the scan, ideally placed perpendicular to the feeding arteries, requires considerable expertise and can present a burden to the operator. In the present work, we proposed that the majority of PC-MRI scans can be positioned using an automatic algorithm, leaving only a small fraction of arteries requiring manual positioning. We implemented and evaluated an algorithm for this purpose based on feature extraction of a survey angiogram, which is of minimal operator dependence. In a comparative test-retest study with 7 subjects, the blood flow measurement using this algorithm showed an inter-session coefficient of variation (CoV) of . The Bland-Altman method showed that the automatic method differs from the manual method by between and , for of the CBF measurements. This is comparable to the variance in CBF measurement using manually-positioned PC MRI alone. In a further application of this algorithm to 157 consecutive subjects from typical clinical cohorts, the algorithm provided successful positioning in 89.7% of the arteries. In 79.6% of the subjects, all four arteries could be planned using the algorithm. Chi-square tests of independence showed that the success rate was not dependent on the age or gender, but the patients showed a trend of lower success rate (p = 0.14) compared to healthy controls. In conclusion, this automatic positioning algorithm could improve the application of PC-MRI in CBF quantification. PMID:24787742
Federal Register 2010, 2011, 2012, 2013, 2014
2010-11-30
... System Testing and Certification Program, Version 2.0 AGENCY: United States Election Assistance Commission (EAC). ACTION: Notice; publication of Voting System Testing and Certification Manual, Version 2.0, for 60 day public comment period on EAC Web site. SUMMARY: The U.S. Election Assistance Commission...
Regents Examinations and Competency Tests. School Administrator's Manual, June 1985 Edition.
ERIC Educational Resources Information Center
1985
Intended for use by school administrators, guidance counselors, teachers and proctors, this manual contains general information on the New York State Regents examinations and competency tests, as well as specific regulations and procedures for ordering, administering, and rating these examinations. The competency testing requirements for a local…
van Heeswijk, Miriam M; Lambregts, Doenja M J; van Griethuysen, Joost J M; Oei, Stanley; Rao, Sheng-Xiang; de Graaff, Carla A M; Vliegen, Roy F A; Beets, Geerard L; Papanikolaou, Nikos; Beets-Tan, Regina G H
2016-03-15
Diffusion-weighted imaging (DWI) tumor volumetry is promising for rectal cancer response assessment, but an important drawback is that manual per-slice tumor delineation can be highly time consuming. This study investigated whether manual DWI-volumetry can be reproduced using a (semi)automated segmentation approach. Seventy-nine patients underwent magnetic resonance imaging (MRI) that included DWI (highest b value [b1000 or b1100]) before and after chemoradiation therapy (CRT). Tumor volumes were assessed on b1000 (or b1100) DWI before and after CRT by means of (1) automated segmentation (by 2 inexperienced readers), (2) semiautomated segmentation (manual adjustment of the volumes obtained by method 1 by 2 radiologists), and (3) manual segmentation (by 2 radiologists); this last assessment served as the reference standard. Intraclass correlation coefficients (ICC) and Dice similarity indices (DSI) were calculated to evaluate agreement between different methods and observers. Measurement times (from a radiologist's perspective) were recorded for each method. Tumor volumes were not significantly different among the 3 methods, either before or after CRT (P=.08 to .92). ICCs compared to manual segmentation were 0.80 to 0.91 and 0.53 to 0.66 before and after CRT, respectively, for the automated segmentation and 0.91 to 0.97 and 0.61 to 0.75, respectively, for the semiautomated method. Interobserver agreement (ICC) pre and post CRT was 0.82 and 0.59 for automated segmentation, 0.91 and 0.73 for semiautomated segmentation, and 0.91 and 0.75 for manual segmentation, respectively. Mean DSI between the automated and semiautomated method were 0.83 and 0.58 pre-CRT and post-CRT, respectively; DSI between the automated and manual segmentation were 0.68 and 0.42 and 0.70 and 0.41 between the semiautomated and manual segmentation, respectively. Median measurement time for the radiologists was 0 seconds (pre- and post-CRT) for the automated method, 41 to 69 seconds (pre-CRT) and 60 to 67 seconds (post-CRT) for the semiautomated method, and 180 to 296 seconds (pre-CRT) and 84 to 91 seconds (post-CRT) for the manual method. DWI volumetry using a semiautomated segmentation approach is promising and a potentially time-saving alternative to manual tumor delineation, particularly for primary tumor volumetry. Once further optimized, it could be a helpful tool for tumor response assessment in rectal cancer. Copyright © 2016 Elsevier Inc. All rights reserved.
A metronome for pacing manual ventilation in a neonatal resuscitation simulation.
Cocucci, Cecilia; Madorno, Matías; Aguilar, Adriana; Acha, Leila; Szyld, Edgardo; Musante, Gabriel
2015-01-01
During manual positive pressure ventilation (PPV), delivering a recommended respiratory rate (RR) is operator dependent. We tested the efficacy of a metronome as a standardised method to improve the accuracy of delivered RR during manual PPV in a neonatal resuscitation simulation. We conducted a blinded simulation in two consecutive stages. Using a self-inflating bag, 36 CPR trained operators provided PPV to a modified neonatal manikin via an endotracheal tube. Pressure and flow signals were captured by a respiratory function monitor. In the first standard stage, participants delivered RR as they would in delivery room. Prior to the second stage, they were asked about what their target RR had been and a metronome was set to that target. Subsequently, operators repeated PPV attempting to coordinate their delivered RR with the metronome. To evaluate accuracy we generated the variable RR Gap as the absolute difference between delivered and target RR. The primary outcome was the difference in RR Gap between stages. Mean (SD) target RR was 50 (8.7) inflations/min. During the initial stage, median (IQR) RR Gap was 11.6 (4.7-18.3) inflations/min and 20/36 participants (55.5%) had a mean delivered RR beyond the recommended range. When paced by the metronome, RR Gap was reduced to 0.2 (0.1-0.4) inflations/min and 32/36 participants (89%) fell within the recommended range. The use of a metronome improved the accuracy of delivered RR during manual PPV. Novel approaches to deliver an accurate RR during manual PPV need to be tested in more realistic scenarios. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://group.bmj.com/group/rights-licensing/permissions.
Tests to measure the quality of spermatozoa at spermiation
Amann, Rupert P.
2010-01-01
This commentary is to critique the revised World Health Organization (WHO) semen analysis manual as it pertains to characteristics of a spermatozoon at spermiation. The aims of the revised WHO manual include improving the 'quality of semen analysis' without any restriction to clinical use. Furthermore, the manual states that semen analysis may be useful for (a) 'investigating male fertility status' and (b) 'monitoring spermatogenesis during and following male fertility regulation.' However, if the analysis of ejaculated spermatozoa is intended for the purposes described in (b), then cells that are abnormal at spermiation must be identified. This paper takes the position that the manual does not identify methods to estimate the quality of spermatozoa at spermiation. Instead, it uses a 'gold standard' of sperm passing through the cervical mucus or arriving near the site of fertilization. Although this standard is appropriate for drawing conclusions regarding the probability that an individual could impregnate his partner, it is not appropriate for studying illness of the testes per se. Herein, the measures of sperm quality presented in the WHO manual are critiqued with respect to the detection of spermatozoa that were abnormal at spermiation vs. those that became abnormal subsequently. Quality assessments based on the percentage of motile or 'viable' spermatozoa are meaningless. Alternative quality attributes defining spermatozoa at spermiation are presented in this paper. In conclusion, assessment of spermatozoal quality at spermiation, on the basis of quality attributes of individual ejaculated spermatozoa, is best achieved through application of (a) a new paradigm for the morphological evaluation of sperm quality and (b) modern analytical techniques to evaluate, in an adequate sample, several appropriate independent attributes in each spermatozoon in order to more accurately identify the proportion of abnormal spermatozoa. PMID:20111084
Gingival abrasion and recession in manual and oscillating–rotating power brush users
Rosema, NAM; Adam, R; Grender, JM; Van der Sluijs, E; Supranoto, SC; Van der Weijden, GA
2014-01-01
Objective To assess gingival recession (GR) in manual and power toothbrush users and evaluate the relationship between GR and gingival abrasion scores (GA). Methods This was an observational (cross-sectional), single-centre, examiner-blind study involving a single-brushing exercise, with 181 young adult participants: 90 manual brush users and 91 oscillating–rotating power brush users. Participants were assessed for GR and GA as primary response variables. Secondary response variables were the level of gingival inflammation, plaque score reduction and brushing duration. Pearson correlation was used to describe the relationship between number of recession sites and number of abrasions. Prebrushing (baseline) and post-brushing GA and plaque scores were assessed and differences analysed using paired tests. Two-sample t-test was used to analyse group differences; ancova was used for analyses of post-brushing changes with baseline as covariate. Results Overall, 97.8% of the study population had at least one site of ≥1 mm of gingival recession. For the manual group, this percentage was 98.9%, and for the power group, this percentage was 96.7% (P = 0.621). Post-brushing, the power group showed a significantly smaller GA increase than the manual group (P = 0.004); however, there was no significant correlation between number of recession sites and number of abrasions for either group (P ≥ 0.327). Conclusions Little gingival recession was observed in either toothbrush user group; the observed GR levels were comparable. Lower post-brushing gingival abrasion levels were seen in the power group. There was no correlation between gingival abrasion as a result of brushing and the observed gingival recession following use of either toothbrush. PMID:24871587
The Identification of Software Failure Regions
1990-06-01
be used to detect non-obviously redundant test cases. A preliminary examination of the manual analysis method is performed with a set of programs ...failure regions are defined and a method of failure region analysis is described in detail. The thesis describes how this analysis may be used to detect...is the termination of the ability of a functional unit to perform its required function. (Glossary, 1983) The presence of faults in program code
PAVECHECK : training material updated user's manual including GPS.
DOT National Transportation Integrated Search
2009-01-01
PAVECHECK is a software package used to integrate nondestructive test data from various testing systems to provide the pavement engineer with a comprehensive evaluation of both surface and subsurface conditions. This User's Manual is intended to demo...
Manual for guided home exercises for osteoarthritis of the knee
de Almeida Carvalho, Nilza Aparecida; Bittar, Simoni Teixeira; de Souza Pinto, Flávia Ribeiro; Ferreira, Mônica; Sitta, Robson Roberto
2010-01-01
INTRODUCTION: Physiotherapy is one of the most important components of therapy for osteoarthritis of the knee. The objective of this prospective case series was to assess the efficiency of a guidance manual for patients with osteoarthritis of the knee in relation to pain, range of movement , muscle strength and function, active goniometry, manual strength test and function. METHODS: Thirty-eight adults with osteoarthritis of the knee (≥ 45 years old) who were referred to the physiotherapy service at the university hospital (Santa Casa de Misericórdia de São Paulo) were studied. Patients received guidance for the practice of specific physical exercises and a manual with instructions on how to perform the exercises at home. They were evaluated for pain, range of movement, muscle strength and function. These evaluations were performed before they received the manual and three months later. Patients were seen monthly regarding improvements in their exercising abilities. RESULTS: The program was effective for improving muscle strength, controlling pain, maintaining range of movement of the knee joint, and reducing functional incapacity. DISCUSSION: A review of the literature showed that there are numerous clinical benefits to the regular practice of physical therapy exercises by patients with osteoarthritis of the knee(s) in a program with appropriate guidance. This study shows that this guidance can be attained at home with the use of a proper manual. CONCLUSIONS: Even when performed at home without constant supervision, the use of the printed manual for orientation makes the exercises for osteoarthritis of the knee beneficial. PMID:20835554
TECRA Unique test for rapid detection of Salmonella in food: collaborative study.
Hughes, D; Dailianis, A E; Hill, L; McIntyre, D A; Anderson, A
2001-01-01
The TECRA Unique Salmonella test uses the principle of immunoenrichment to allow rapid detection of Salmonellae in food. A collaborative study was conducted to compare the TECRA Salmonella Unique test with the reference culture method given in the U.S. Food and Drug Administration's Bacteriological Analytical Manual. Three food types (milk powder, pepper, and soy flour) were analyzed in Australia and 2 food types (milk chocolate and dried egg) were analyzed in the United States. Forty-one collaborators participated in the study. For each of the 5 foods at each of the 3 levels, a comparison showed no significant differences (p > or = 0.05) in the proportion of positive test samples for Unique and that for the reference method using the Chi-square test for independence with continuity correction.
ERIC Educational Resources Information Center
Koppitz, Elizabeth Munsterberg
Presented is a manual for scoring the Bender Gestalt Test and the Human Figure Drawing Test for screening and diagnostic uses with emotionally disturbed, brain damaged, or perceptually handicapped 5- to 11-year-old children. Given are suggestions for administering and scoring the Bender test which examines distortion of shape, rotation,…
Oliveira, M; Lopez, G; Geambastiani, P; Ubeda, C
2018-05-01
A quality assurance (QA) program is a valuable tool for the continuous production of optimal quality images. The aim of this paper is to assess a newly developed automatic computer software for image quality (IR) evaluation in fluoroscopy X-ray systems. Test object images were acquired using one fluoroscopy system, Siemens Axiom Artis model (Siemens AG, Medical Solutions Erlangen, Germany). The software was developed as an ImageJ plugin. Two image quality parameters were assessed: high-contrast spatial resolution (HCSR) and signal-to-noise ratio (SNR). The time between manual and automatic image quality assessment procedures were compared. The paired t-test was used to assess the data. p Values of less than 0.05 were considered significant. The Fluoro-QC software generated faster IQ evaluation results (mean = 0.31 ± 0.08 min) than manual procedure (mean = 4.68 ± 0.09 min). The mean difference between techniques was 4.36 min. Discrepancies were identified in the region of interest (ROI) areas drawn manually with evidence of user dependence. The new software presented the results of two tests (HCSR = 3.06, SNR = 5.17) and also collected information from the DICOM header. Significant differences were not identified between manual and automatic measures of SNR (p value = 0.22) and HCRS (p value = 0.46). The Fluoro-QC software is a feasible, fast and free to use method for evaluating imaging quality parameters on fluoroscopy systems. Copyright © 2017 The College of Radiographers. Published by Elsevier Ltd. All rights reserved.
Comparison of Manual Refraction Versus Autorefraction in 60 Diabetic Retinopathy Patients
Shirzadi, Keyvan; Shahraki, Kourosh; Yahaghi, Emad; Makateb, Ali; Khosravifard, Keivan
2016-01-01
Aim: The purpose of the study was to evaluate the comparison of manual refraction versus autorefraction in diabetic retinopathy patients. Material and Methods: The study was conducted at the Be’sat Army Hospital from 2013-2015. In the present study differences between two common refractometry methods (manual refractometry and Auto refractometry) in diagnosis and follow up of retinopathy in patients affected with diabetes is investigated. Results: Our results showed that there is a significant difference in visual acuity score of patients between manual and auto refractometry. Despite this fact, spherical equivalent scores of two methods of refractometry did not show a significant statistical difference in the patients. Conclusion: Although use of manual refraction is comparable with autorefraction in evaluating spherical equivalent scores in diabetic patients affected with retinopathy, but in the case of visual acuity results from these two methods are not comparable. PMID:27703289
Belete, Tamrat; Crowley, Erin; Bird, Patrick; Gensic, Joseph; Wallace, F Morgan
2014-10-01
The performances of two DuPont BAX System PCR assays for detecting Salmonella on a variety of low-moisture soy ingredients were evaluated against the U. S. Food and Drug Administration's Bacteriological Analytical Manual (FDA BAM) method or the International Organization for Standardization (ISO) 6579 reference method. These evaluations were conducted as a single laboratory validation at an ISO 17025 accredited third-party laboratory. Validations were conducted on five soy ingredients: isolated soy protein (ISP), soy fiber, fluid soy lecithin, deoiled soy lecithin, and soy nuggets, using a paired-study design. The ISP was analyzed as both 25- and 375-g composite test portions, whereas all other sample matrices were analyzed as 375-g composite test portions. To evaluate 25-g test portions of ISP, the test material was inoculated using Salmonella enterica subsp. enterica serovar Mbandaka (Q Laboratories isolate 11031.1). Salmonella enterica subsp. enterica serovar Tennessee (Q Laboratories isolate 11031.3) was used for all other trials. For each trial of the method comparison, 25 samples were analyzed for each matrix: 5 uninoculated controls and 20 samples inoculated at low levels (0.2 to 2 CFU per test portion) that were targeted to achieve fractionally positive results (25 to 75%). Using McNemar's chi-square analysis, no significant difference at P ≥ 0.05 (χ(2) ≤ 3.84) was observed between the number of positives obtained by the BAX System and the reference methods for all five test matrices evaluated. These studies indicate that the BAX System PCR assays, in combination with the single buffered peptone water primary enrichment and subsequent brain heart infusion regrowth step, demonstrate equivalent sensitivity and robustness compared with the FDA BAM and ISO reference methods for both 25- and 375-g composite samples. Moreover, there was no observed reduction of sensitivity in the larger 375-g composite samples for all five matrices.
Course Manual for X-Ray Measurements.
ERIC Educational Resources Information Center
Food and Drug Administration (DHEW), Rockville, MD. Bureau of Radiological Health.
This is the second of a series of three instructor manuals in x-ray science and engineering and is produced as part of a project of Oregon State University's Bureau of Radiological Health. This manual, and the two campanion manuals, have been tested in courses at Oregon State. These materials have been designed to serve as models for teaching and…
Sierra/SolidMechanics 4.48 Verification Tests Manual.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Plews, Julia A.; Crane, Nathan K; de Frias, Gabriel Jose
2018-03-01
Presented in this document is a small portion of the tests that exist in the Sierra / SolidMechanics (Sierra / SM) verification test suite. Most of these tests are run nightly with the Sierra / SM code suite, and the results of the test are checked versus the correct analytical result. For each of the tests presented in this document, the test setup, a description of the analytic solution, and comparison of the Sierra / SM code results to the analytic solution is provided. Mesh convergence is also checked on a nightly basis for several of these tests. This documentmore » can be used to confirm that a given code capability is verified or referenced as a compilation of example problems. Additional example problems are provided in the Sierra / SM Example Problems Manual. Note, many other verification tests exist in the Sierra / SM test suite, but have not yet been included in this manual.« less
Sierra/SolidMechanics 4.48 Verification Tests Manual.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Plews, Julia A.; Crane, Nathan K.; de Frias, Gabriel Jose
Presented in this document is a small portion of the tests that exist in the Sierra / SolidMechanics (Sierra / SM) verification test suite. Most of these tests are run nightly with the Sierra / SM code suite, and the results of the test are checked versus the correct analytical result. For each of the tests presented in this document, the test setup, a description of the analytic solution, and comparison of the Sierra / SM code results to the analytic solution is provided. Mesh convergence is also checked on a nightly basis for several of these tests. This documentmore » can be used to confirm that a given code capability is verified or referenced as a compilation of example problems. Additional example problems are provided in the Sierra / SM Example Problems Manual. Note, many other verification tests exist in the Sierra / SM test suite, but have not yet been included in this manual.« less
NASA Technical Reports Server (NTRS)
Berg, Melanie D.; LaBel, Kenneth A.
2018-01-01
The following are updated or new subjects added to the FPGA SEE Test Guidelines manual: academic versus mission specific device evaluation, single event latch-up (SEL) test and analysis, SEE response visibility enhancement during radiation testing, mitigation evaluation (embedded and user-implemented), unreliable design and its affects to SEE Data, testing flushable architectures versus non-flushable architectures, intellectual property core (IP Core) test and evaluation (addresses embedded and user-inserted), heavy-ion energy and linear energy transfer (LET) selection, proton versus heavy-ion testing, fault injection, mean fluence to failure analysis, and mission specific system-level single event upset (SEU) response prediction. Most sections within the guidelines manual provide information regarding best practices for test structure and test system development. The scope of this manual addresses academic versus mission specific device evaluation and visibility enhancement in IP Core testing.
NASA Technical Reports Server (NTRS)
Berg, Melanie D.; LaBel, Kenneth A.
2018-01-01
The following are updated or new subjects added to the FPGA SEE Test Guidelines manual: academic versus mission specific device evaluation, single event latch-up (SEL) test and analysis, SEE response visibility enhancement during radiation testing, mitigation evaluation (embedded and user-implemented), unreliable design and its affects to SEE Data, testing flushable architectures versus non-flushable architectures, intellectual property core (IP Core) test and evaluation (addresses embedded and user-inserted), heavy-ion energy and linear energy transfer (LET) selection, proton versus heavy-ion testing, fault injection, mean fluence to failure analysis, and mission specific system-level single event upset (SEU) response prediction. Most sections within the guidelines manual provide information regarding best practices for test structure and test system development. The scope of this manual addresses academic versus mission specific device evaluation and visibility enhancement in IP Core testing.
SAS molecular tests Salmonella detection kit. Performance tested method 021202.
Bapanpally, Chandra; Montier, Laura; Khan, Shah; Kasra, Akif; Brunelle, Sharon L
2014-01-01
The SAS Molecular tests Salmonella Detection method, a Loop-mediated Isothermal Amplification method, performed as well as or better than the U.S. Department of Agriculture-Food Safety Inspection Service Microbiology Laboratory Guidebook and the U.S. Food and Drug Administration Bacteriological Analytical Manual reference methods for ground beef, beef trim, ground turkey, chicken carcass rinses, bagged mixed lettuce, and fresh spinach. The ground beef (30% fat, 25 g test portion), poultry matrixes and leafy greens were validated in a 6-7 h enrichment, and ground beef (30% fat, 375 g composite test portion) and beef trim (375 g composite test portion) were validated in a 16-20 h enrichment. The method performance for meat and leafy green matrixes was shown to be acceptable under conditions of co-enrichment with Escherichia coli 0157. Thus, after a short 6-7 h co-enrichment step, ground beef, beef trim, lettuce, and spinach can be tested for both Salmonella and E. coli O157. Inclusivity and exclusivity testing revealed no false negatives and no false positives among the 100 Salmonella serovars and 30 non-Salmonella species examined. The method was shown to be robust when enrichment time, DNA extract hold time, and DNA volume were varied.
Automated classification of Acid Rock Drainage potential from Corescan drill core imagery
NASA Astrophysics Data System (ADS)
Cracknell, M. J.; Jackson, L.; Parbhakar-Fox, A.; Savinova, K.
2017-12-01
Classification of the acid forming potential of waste rock is important for managing environmental hazards associated with mining operations. Current methods for the classification of acid rock drainage (ARD) potential usually involve labour intensive and subjective assessment of drill core and/or hand specimens. Manual methods are subject to operator bias, human error and the amount of material that can be assessed within a given time frame is limited. The automated classification of ARD potential documented here is based on the ARD Index developed by Parbhakar-Fox et al. (2011). This ARD Index involves the combination of five indicators: A - sulphide content; B - sulphide alteration; C - sulphide morphology; D - primary neutraliser content; and E - sulphide mineral association. Several components of the ARD Index require accurate identification of sulphide minerals. This is achieved by classifying Corescan Red-Green-Blue true colour images into the presence or absence of sulphide minerals using supervised classification. Subsequently, sulphide classification images are processed and combined with Corescan SWIR-based mineral classifications to obtain information on sulphide content, indices representing sulphide textures (disseminated versus massive and degree of veining), and spatially associated minerals. This information is combined to calculate ARD Index indicator values that feed into the classification of ARD potential. Automated ARD potential classifications of drill core samples associated with a porphyry Cu-Au deposit are compared to manually derived classifications and those obtained by standard static geochemical testing and X-ray diffractometry analyses. Results indicate a high degree of similarity between automated and manual ARD potential classifications. Major differences between approaches are observed in sulphide and neutraliser mineral percentages, likely due to the subjective nature of manual estimates of mineral content. The automated approach presented here for the classification of ARD potential offers rapid, repeatable and accurate outcomes comparable to manually derived classifications. Methods for automated ARD classifications from digital drill core data represent a step-change for geoenvironmental management practices in the mining industry.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Yu, Y. Q.; Shemon, E. R.; Thomas, J. W.
SHARP is an advanced modeling and simulation toolkit for the analysis of nuclear reactors. It is comprised of several components including physical modeling tools, tools to integrate the physics codes for multi-physics analyses, and a set of tools to couple the codes within the MOAB framework. Physics modules currently include the neutronics code PROTEUS, the thermal-hydraulics code Nek5000, and the structural mechanics code Diablo. This manual focuses on performing multi-physics calculations with the SHARP ToolKit. Manuals for the three individual physics modules are available with the SHARP distribution to help the user to either carry out the primary multi-physics calculationmore » with basic knowledge or perform further advanced development with in-depth knowledge of these codes. This manual provides step-by-step instructions on employing SHARP, including how to download and install the code, how to build the drivers for a test case, how to perform a calculation and how to visualize the results. Since SHARP has some specific library and environment dependencies, it is highly recommended that the user read this manual prior to installing SHARP. Verification tests cases are included to check proper installation of each module. It is suggested that the new user should first follow the step-by-step instructions provided for a test problem in this manual to understand the basic procedure of using SHARP before using SHARP for his/her own analysis. Both reference output and scripts are provided along with the test cases in order to verify correct installation and execution of the SHARP package. At the end of this manual, detailed instructions are provided on how to create a new test case so that user can perform novel multi-physics calculations with SHARP. Frequently asked questions are listed at the end of this manual to help the user to troubleshoot issues.« less
Designing a User Manual to Support an In-House Database.
ERIC Educational Resources Information Center
Kraft, Melissa A.; Pugh, W. Jean
1988-01-01
Describes the steps involved in designing a user manual for an in-house database. Topics covered include goal definition, target audience identification, production scheduling, design and production choices, testing and review, and updating of the manual. (CLB)
Azin, Mahdieh; Zangiabadi, Nasser; Iranmanesh, Farhad; Baneshi, Mohammad Reza; Banihashem, Seyedshahab
2016-01-01
Background Intermittent theta burst stimulation (iTBS) is a repetitive transcranial magnetic stimulation (rTMS) protocol that influences cortical excitability and motor function recovery. Objectives This study aimed to investigate the effects of iTBS on manual dexterity and hand motor imagery in multiple sclerosis (MS) patients. Methods Thirty-six MS patients were non-randomly assigned into sham (control) or iTBS groups. Then, iTBS was delivered to the primary motor cortex for ten days over two consecutive weeks. The patients’ manual dexterity was assessed using the nine-hole peg test (9HPT) and the Box and Block Test (BBT), while the hand motor imagery was assessed with the hand mental rotation task (HMRT). Results iTBS group showed a reduction in the time required to complete the 9HPT (mean difference = -3.05, P = 0.002), and an increase in the number of blocks transferred in one minute in the BBT (mean difference = 8.9, P = 0.001) when compared to the control group. Furthermore, there was no significant difference between the two groups in terms of the reaction time (P = 0.761) and response accuracy rate (P = 0.482) in the HMRT. Conclusions When iTBS was applied over the primary motor cortex, it significantly improved manual dexterity, but had no significant effect on the hand motor imagery ability in MS patients. PMID:28180015
THERM 5 / WINDOW 5 NFRC simulation manual
DOE Office of Scientific and Technical Information (OSTI.GOV)
Mitchell, Robin; Kohler, Christian; Arasteh, Dariush
This document, the ''THERM 5/WINDOW 5 NFRC Simulation Manual', discusses how to use the THERM and WINDOW programs to model products for NFRC certified simulations and assumes that the user is already familiar with those programs. In order to learn how to use these programs, it is necessary to become familiar with the material in both the ''THERM User's Manual'' and the ''WINDOW User's Manual''. In general, this manual references the User's Manuals rather than repeating the information. If there is a conflict between either of the User Manual and this ''THERM 5/''WINDOW 5 NFRC Simulation Manual'', the ''THERM 5/WINDOWmore » 5 NFRC Simulation Manual'' takes precedence. In addition, if this manual is in conflict with any NFRC standards, the standards take precedence. For example, if samples in this manual do not follow the current taping and testing NFRC standards, the standards not the samples in this manual, take precedence.« less
Jiang, Hui; Hanna, Eriny; Gatto, Cheryl L; Page, Terry L; Bhuva, Bharat; Broadie, Kendal
2016-03-01
Aversive olfactory classical conditioning has been the standard method to assess Drosophila learning and memory behavior for decades, yet training and testing are conducted manually under exceedingly labor-intensive conditions. To overcome this severe limitation, a fully automated, inexpensive system has been developed, which allows accurate and efficient Pavlovian associative learning/memory analyses for high-throughput pharmacological and genetic studies. The automated system employs a linear actuator coupled to an odorant T-maze with airflow-mediated transfer of animals between training and testing stages. Odorant, airflow and electrical shock delivery are automatically administered and monitored during training trials. Control software allows operator-input variables to define parameters of Drosophila learning, short-term memory and long-term memory assays. The approach allows accurate learning/memory determinations with operational fail-safes. Automated learning indices (immediately post-training) and memory indices (after 24h) are comparable to traditional manual experiments, while minimizing experimenter involvement. The automated system provides vast improvements over labor-intensive manual approaches with no experimenter involvement required during either training or testing phases. It provides quality control tracking of airflow rates, odorant delivery and electrical shock treatments, and an expanded platform for high-throughput studies of combinational drug tests and genetic screens. The design uses inexpensive hardware and software for a total cost of ∼$500US, making it affordable to a wide range of investigators. This study demonstrates the design, construction and testing of a fully automated Drosophila olfactory classical association apparatus to provide low-labor, high-fidelity, quality-monitored, high-throughput and inexpensive learning and memory behavioral assays. Copyright © 2015 Elsevier B.V. All rights reserved.
ERIC Educational Resources Information Center
Wise, Edward A.; Streiner, David L.; Walfish, Steven
2010-01-01
This article provides a review of the literature to determine the most frequently used personality tests. Based on this review, internal consistency and test-retest reliability coefficients from the test manuals for the Minnesota Multiphasic Personality Inventory-2 (MMPI-2), Millon Clinical Multiaxial Inventory-III (MCMI-III), and Personality…
Sierra/SolidMechanics 4.46 Example Problems Manual.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Plews, Julia A.; Crane, Nathan K; de Frias, Gabriel Jose
Presented in this document are tests that exist in the Sierra/SolidMechanics example problem suite, which is a subset of the Sierra/SM regression and performance test suite. These examples showcase common and advanced code capabilities. A wide variety of other regression and verification tests exist in the Sierra/SM test suite that are not included in this manual.
Nicoletti, S; Battevi, N; Colafemmina, G; Di Leone, G; Satriani, G; Ragone, P; Occhipinti, E
2013-01-01
The Basilicata Regional Headquarters of the Italian Institute for Insurance against Occupational Accidents and Disease (INAIL) and the Basilicata association of small building enterprises (Edilcassa di Basilicata) promoted a research project to assess the risk of manual lifting and manual transport in construction enterprises in the Basilicata Region and estimate the prevalence of related diseases. Manual lifting risk assessment was performed by calculating the VLI of 204 working days in as many building workers. Manual transport risk assessment was carried out comparing the weights transported (on the 204 days tested) with the reference values of the "Snoock and Ciriello" tables. Manual Ifting risk was present on 195 of the 204 days, with an average value of VLI equal to 2.1 (min 0.4, max 8.5), with higher values in the restructuring sector (VLI average of 2.3, min 0.4, max 8.5), and no significant differences between the different tasks. Manual transport risk was present on 129 of the 204 days, with average values of 1.2 (min 0.2, max 3.3), with no significant differences between the different tasks analyzed For both risks additional factors were present that were not analyzed by the methods of assessment used (for manual lifting: 8.8% of the geometries in the critical area; for manual transport: 39% of transport on shoulders, 42.5% on a route with uneven surface and 31.9% on a sloping route), so it is likely that the actual risk is greater than that indicated by the synthetic indices of exposure. The medical questionnaire showed from the case histories that 148 out of 546 subjects were positive for the threshold forpain or discomfort in the lumbosacral spine area and 99 out of 546 subjects reported suffering from an already diagnosed herniated spinal disk. Only 18% of osteoarticular diseases was reported to the Insurance Institute, al though there was widespread awareness that the diseases in question might be related to work. Diseases of the spine were responsible for 1.9% of absenteeism, equal to 30-40% of total absenteeism ofworkers enrolled in "Edilcassa di Basilicata". The method used provides a solid basis for evaluating the two risks in the construction industry, where employment is subject to extreme organizational, environmental and structural (machines, tools, operators involved) variability. Employment in the construction industry involves significant exposure to the two risks, counting for 30-40% of total absenteeism in this sector.
Primary Test of Economic Understanding. Examiner's Manual. Revised Edition.
ERIC Educational Resources Information Center
Iowa Univ., Iowa City. Bureau of Business and Economic Research.
This manual for examiners administering the Primary Test of Economic Understanding (PTEU) describes the purpose, development, and validity of the test which is designed to provide a measure of students' growth and a means to assess the effectiveness of existing materials, teaching strategies, and pre-service and in-service economics education…
Software-assisted small bowel motility analysis using free-breathing MRI: feasibility study.
Bickelhaupt, Sebastian; Froehlich, Johannes M; Cattin, Roger; Raible, Stephan; Bouquet, Hanspeter; Bill, Urs; Patak, Michael A
2014-01-01
To validate a software prototype allowing for small bowel motility analysis in free breathing by comparing it to manual measurements. In all, 25 patients (15 male, 10 female; mean age 39 years) were included in this Institutional Review Board-approved, retrospective study. Magnetic resonance imaging (MRI) was performed on a 1.5T system after standardized preparation acquiring motility sequences in free breathing over 69-84 seconds. Small bowel motility was analyzed manually and with the software. Functional parameters, measurement time, and reproducibility were compared using the coefficient of variance and paired Student's t-test. Correlation was analyzed using Pearson's correlation coefficient and linear regression. The 25 segments were analyzed twice both by hand and using the software with automatic breathing correction. All assessed parameters significantly correlated between the methods (P < 0.01), but the scattering of repeated measurements was significantly (P < 0.01) lower using the software (3.90%, standard deviation [SD] ± 5.69) than manual examinations (9.77%, SD ± 11.08). The time needed was significantly less (P < 0.001) with the software (4.52 minutes, SD ± 1.58) compared to manual measurement, lasting 17.48 minutes for manual (SD ± 1.75 minutes). The use of the software proves reliable and faster small bowel motility measurements in free-breathing MRI compared to manual analyses. The new technique allows for analyses of prolonged sequences acquired in free breathing, improving the informative value of the examinations by amplifying the evaluable data. Copyright © 2013 Wiley Periodicals, Inc.
ERIC Educational Resources Information Center
Gomez, Rapson
2012-01-01
Objective: Generalized partial credit model, which is based on item response theory (IRT), was used to test differential item functioning (DIF) for the "Diagnostic and Statistical Manual of Mental Disorders" (4th ed.), inattention (IA), and hyperactivity/impulsivity (HI) symptoms across boys and girls. Method: To accomplish this, parents completed…
A manual 24-h integrated method for determining SO2, NOx, and CO2 in emissions from electric utility plants was developed and field tested downstream from an SO2 control system. Samples were collected in alkaline potassium permanganate solution contained in restricted-orifice imp...
A Parent-Only Group Intervention for Children with Anxiety Disorders: Pilot Study
ERIC Educational Resources Information Center
Thienemann, Margo; Moore, Phoebe; Tompkins, Kim
2006-01-01
Objective: Working to optimize treatment outcome and use resources efficiently, investigators conducted the first test of an existing parent-only group cognitive-behavioral therapy protocol to treat 24 children 7 to 16 years old with primary anxiety disorder diagnoses. Method: Over the course of 7 months, the authors evaluated a manual-based…
7 CFR 91.23 - Analytical methods.
Code of Federal Regulations, 2014 CFR
2014-01-01
... 7 Agriculture 3 2014-01-01 2014-01-01 false Analytical methods. 91.23 Section 91.23 Agriculture... SERVICES AND GENERAL INFORMATION Method Manuals § 91.23 Analytical methods. Most analyses are performed according to approved procedures described in manuals of standardized methodology. These standard methods...
7 CFR 91.23 - Analytical methods.
Code of Federal Regulations, 2011 CFR
2011-01-01
... 7 Agriculture 3 2011-01-01 2011-01-01 false Analytical methods. 91.23 Section 91.23 Agriculture... SERVICES AND GENERAL INFORMATION Method Manuals § 91.23 Analytical methods. Most analyses are performed according to approved procedures described in manuals of standardized methodology. These standard methods...
7 CFR 91.23 - Analytical methods.
Code of Federal Regulations, 2013 CFR
2013-01-01
... 7 Agriculture 3 2013-01-01 2013-01-01 false Analytical methods. 91.23 Section 91.23 Agriculture... SERVICES AND GENERAL INFORMATION Method Manuals § 91.23 Analytical methods. Most analyses are performed according to approved procedures described in manuals of standardized methodology. These standard methods...
Validation of Interdisciplinary Cooperative Education Manual.
ERIC Educational Resources Information Center
Stone, Sheila D.
A field test examined the validity of the "Interdisciplinary Cooperative Education Curriculum Manual." (Among those topics covered in the manual are the following: vocational student organizations, leadership, civic responsibility, health and safety, human relations, communications, resource management, consumer skills, consumer law,…
Field manual for the collection of Navajo Nation streamflow-gage data
Hart, Robert J.; Fisk, Gregory G.
2014-01-01
The Field Manual for the Collection of Navajo Nation Streamflow-Gage Data (Navajo Field Manual) is based on established (standard) U.S. Geological Survey streamflow-gaging methods and provides guidelines specifically designed for the Navajo Department of Water Resources personnel who establish and maintain streamflow gages. The Navajo Field Manual addresses field visits, including essential field equipment and the selection of and routine visits to streamflow-gaging stations, examines surveying methods for determining peak flows (indirect measurements), discusses safety considerations, and defines basic terms.
The CAHPER Fitness-Performance Test Manual: For Boys and Girls 7 to 17 Years of Age.
ERIC Educational Resources Information Center
Canadian Association for Health, Physical Education, and Recreation, Ottawa (Ontario).
Outlined in this manual is Canada's first National Test of Physical Fitness. Each test item is a valid and reliable measure of fitness, simple enough for any teacher not trained in fitness measurement to administer. Each of the six tests measures a different aspect of fitness: (1) the one-minute speed sit-up tests the strength and endurance of the…
Generation algorithm of craniofacial structure contour in cephalometric images
NASA Astrophysics Data System (ADS)
Mondal, Tanmoy; Jain, Ashish; Sardana, H. K.
2010-02-01
Anatomical structure tracing on cephalograms is a significant way to obtain cephalometric analysis. Computerized cephalometric analysis involves both manual and automatic approaches. The manual approach is limited in accuracy and repeatability. In this paper we have attempted to develop and test a novel method for automatic localization of craniofacial structure based on the detected edges on the region of interest. According to the grey scale feature at the different region of the cephalometric images, an algorithm for obtaining tissue contour is put forward. Using edge detection with specific threshold an improved bidirectional contour tracing approach is proposed by an interactive selection of the starting edge pixels, the tracking process searches repetitively for an edge pixel at the neighborhood of previously searched edge pixel to segment images, and then craniofacial structures are obtained. The effectiveness of the algorithm is demonstrated by the preliminary experimental results obtained with the proposed method.
Cloud cover determination in polar regions from satellite imagery
NASA Technical Reports Server (NTRS)
Barry, R. G.; Maslanik, J. A.; Key, J. R.
1987-01-01
A definition is undertaken of the spectral and spatial characteristics of clouds and surface conditions in the polar regions, and to the creation of calibrated, geometrically correct data sets suitable for quantitative analysis. Ways are explored in which this information can be applied to cloud classifications as new methods or as extensions to existing classification schemes. A methodology is developed that uses automated techniques to merge Advanced Very High Resolution Radiometer (AVHRR) and Scanning Multichannel Microwave Radiometer (SMMR) data, and to apply first-order calibration and zenith angle corrections to the AVHRR imagery. Cloud cover and surface types are manually interpreted, and manual methods are used to define relatively pure training areas to describe the textural and multispectral characteristics of clouds over several surface conditions. The effects of viewing angle and bidirectional reflectance differences are studied for several classes, and the effectiveness of some key components of existing classification schemes is tested.
Guidelines for cone penetration test : performance and design
DOT National Transportation Integrated Search
1978-07-01
This manual presents procedures and guidelines applicable to the use of the cone penetration test. Dr. Schmertmann prepared this manual in February 1977 and made minor additions in May 1978. It represents his interpretation of the state-of-the-art in...
28 CFR 42.512 - Employment criteria.
Code of Federal Regulations, 2010 CFR
2010-07-01
... sensory, manual, or speaking skills, the test results must accurately reflect the applicant's or employee's job skills, aptitude, or whatever other factor the test purports to measure, rather than reflecting the applicant's or employee's impaired sensory, manual, or speaking skills (except where those...
24 CFR 8.12 - Employment criteria.
Code of Federal Regulations, 2011 CFR
2011-04-01
... handicap that impairs sensory, manual, or speaking skills, the test results accurately reflect the applicant's or employee's job skills, aptitude, or whatever other factor the test purports to measure, rather than the applicant's or employee's impaired sensory, manual, or speaking skills (except where...
24 CFR 8.12 - Employment criteria.
Code of Federal Regulations, 2010 CFR
2010-04-01
... handicap that impairs sensory, manual, or speaking skills, the test results accurately reflect the applicant's or employee's job skills, aptitude, or whatever other factor the test purports to measure, rather than the applicant's or employee's impaired sensory, manual, or speaking skills (except where...
28 CFR 42.512 - Employment criteria.
Code of Federal Regulations, 2011 CFR
2011-07-01
... sensory, manual, or speaking skills, the test results must accurately reflect the applicant's or employee's job skills, aptitude, or whatever other factor the test purports to measure, rather than reflecting the applicant's or employee's impaired sensory, manual, or speaking skills (except where those...
Comparison of analytical methods for the determination of histamine in reference canned fish samples
NASA Astrophysics Data System (ADS)
Jakšić, S.; Baloš, M. Ž.; Mihaljev, Ž.; Prodanov Radulović, J.; Nešić, K.
2017-09-01
Two screening methods for histamine in canned fish, an enzymatic test and a competitive direct enzyme-linked immunosorbent assay (CD-ELISA), were compared with the reversed-phase liquid chromatography (RP-HPLC) standard method. For enzymatic and CD-ELISA methods, determination was conducted according to producers’ manuals. For RP-HPLC, histamine was derivatized with dansyl-chloride, followed by RP-HPLC and diode array detection. Results of analysis of canned fish, supplied as reference samples for proficiency testing, showed good agreement when histamine was present at higher concentrations (above 100 mg kg-1). At a lower level (16.95 mg kg-1), the enzymatic test produced some higher results. Generally, analysis of four reference samples according to CD-ELISA and RP-HPLC showed good agreement for histamine determination (r=0.977 in concentration range 16.95-216 mg kg-1) The results show that the applied enzymatic test and CD-ELISA appeared to be suitable screening methods for the determination of histamine in canned fish.
Feasibility of a Semi-computerized Line Bisection Test for Unilateral Visual Neglect Assessment.
Jee, H; Kim, J; Kim, C; Kim, T; Park, J
2015-01-01
Commonly used paper-and-pencil based test modalities for assessing the degree of unilateral visual neglect (ULN) in patients with hemispheric cerebral lesions consume human resources with a significant inter and intra-rater variability. To explore the feasibility of a semi-computerized electronic-pen based ULN assessment system (e-system) to improve assessment quality without altering the conventional user interface. Thirty cognitively healthy participants (HG) and 11 participants diagnosed with right-hemispheric lesion and unilateral visual neglect (NG) were recruited to evaluate the e-system. Line bisection tests (LBT) were repeatedly conducted twice for the inter-rater and intra-rater (reliability) comparisons. The LBT results were assessed by the e-system and the golden standard methods (manual rater assessment). The percent deviation (%), assessment duration (sec), and number of neglected line (each) were evaluated. The inter-rater comparisons of the assessed deviation (%) variable showed excellent interrater reliabilities (CCCs) ranging from .84 (.59 to .95 (p < .001)) to .99 (.90 to .99 (p < .001)) for HG and NG. The Bland Altman mean difference (B-A) plots with bias (95% LOA (limits of agreement)) showed similar agreements between the e-system and the raters ranging from -.04 % (-2.10 to 1.97) to 1.30 % (-2.23 to 4.84) for HG and NG. The effect sizes (ES), which show similarities between the assessment methods, yielded smaller ranges from .01 to .30 for HG and NG. The reliability (test-retest) comparisons showed similar assessment results between the e-system, rater 1, and rater 2. The manual rater assessment time ranging from 5.85 to 6.00 minutes and inter- and intraassessment variations were virtually eliminated with the e-system. The semi-computerized system with the conventional paper-and pencil user-interface showed valid and reliable assessment results. It may be a feasible replacement for the manual rater assessment modality even in a clinical setting.
Kuretzki, Carlos Henrique; Campos, Antônio Carlos Ligocki; Malafaia, Osvaldo; Soares, Sandramara Scandelari Kusano de Paula; Tenório, Sérgio Bernardo; Timi, Jorge Rufino Ribas
2016-03-01
The use of information technology is often applied in healthcare. With regard to scientific research, the SINPE(c) - Integrated Electronic Protocols was created as a tool to support researchers, offering clinical data standardization. By the time, SINPE(c) lacked statistical tests obtained by automatic analysis. Add to SINPE(c) features for automatic realization of the main statistical methods used in medicine . The study was divided into four topics: check the interest of users towards the implementation of the tests; search the frequency of their use in health care; carry out the implementation; and validate the results with researchers and their protocols. It was applied in a group of users of this software in their thesis in the strict sensu master and doctorate degrees in one postgraduate program in surgery. To assess the reliability of the statistics was compared the data obtained both automatically by SINPE(c) as manually held by a professional in statistics with experience with this type of study. There was concern for the use of automatic statistical tests, with good acceptance. The chi-square, Mann-Whitney, Fisher and t-Student were considered as tests frequently used by participants in medical studies. These methods have been implemented and thereafter approved as expected. The incorporation of the automatic SINPE (c) Statistical Analysis was shown to be reliable and equal to the manually done, validating its use as a research tool for medical research.
Quan, Erik; Mahmood, Rizwan; Naik, Amar; Sargon, Peter; Shastri, Nikhil; Venu, Mukund; Parada, Jorge P; Gupta, Neil
2018-05-21
There have been reported outbreaks of carbapenem-resistant Enterobacteriaceae infections linked to endoscopes with elevator mechanisms. Adenosine triphosphate (ATP) testing has been used as a marker for bioburden and monitoring manual cleaning for flexible endoscopes with and without an elevator mechanism. The objective of this study was to determine whether routine ATP testing could identify areas of improvement in cleaning of endoscopes with an elevator mechanism. ATP testing after manual cleaning of TJF-Q180V duodenoscopes and GF-UCT180 linear echoendoscopes (Olympus America Inc, Center Valley, PA) was implemented. Samples were tested from the distal end, the elevator mechanism, and water flushed through the lumen of the biopsy channel. Data were recorded and compared by time point, test point, and reprocessing technician. Overall failure rate was 6.99% (295 out of 4,219). The highest percentage of failed ATP tests (17.05%) was reported in the first quarter of routine testing, with an overall decrease in rates over time. The elevator mechanism and working channel lumen had higher failure rates than the distal end. Quality of manual cleaning between reprocessing technicians showed variation. ATP testing is effective in identifying residual organic material and improving quality of manual cleaning of endoscopes with an elevator mechanism. Cleaning efficacy is influenced by reprocessing technicians and location tested on the endoscope. Close attention to the working channel and elevator mechanism during manual cleaning is warranted. Copyright © 2018 Association for Professionals in Infection Control and Epidemiology, Inc. Published by Elsevier Inc. All rights reserved.
Beltran-Alacreu, Hector; López-de-Uralde-Villanueva, Ibai; Fernández-Carnero, Josué; La Touche, Roy
2015-10-01
The aim of this study was to determine the effectiveness of a multimodal treatment in the short and medium term for disability in nonspecific chronic neck pain. The design of this study is a single-blinded randomized controlled trial carried out in a university research laboratory. Forty-five patients between 18 and 65 yrs with nonspecific chronic neck pain were included in this study. Each patient was treated eight times over a 4-wk period. The sample was divided into three groups: control group, subjected to a protocol of manual therapy; experimental group 1, subjected to a protocol of manual therapy and therapeutic patient education; and experimental group 2, subjected to manual therapy, therapeutic patient education, and a therapeutic exercise protocol. Assessments were performed at baseline and at 4, 8, and 16 wks using the following measurements: the Neck Disability Index, the 11-item Tampa Scale of Kinesiophobia, the Fear Avoidance Beliefs Questionnaire, the Neck Flexor Muscle Endurance Test, and the Visual Analog Fatigue Scale. The nonparametric Kruskal-Wallis test for the Neck Disability Index showed statistically significant differences between baseline outcomes and all follow-up periods (P < 0.01). In the Kruskal-Wallis test, differences were found for the Visual Analog Fatigue Scale and the Neck Flexor Muscle Endurance Test in the follow-ups at 8 and 16 wks (P < 0.05). Analysis of variance for group × time interaction showed statistically significant changes (Tampa Scale of Kinesiophobia, F = 3.613, P = 0.005; Fear Avoidance Beliefs Questionnaire, F = 2.803, P = 0.022). Minimal detectable changes were obtained in both experimental groups for the 11-item Tampa Scale of Kinesiophobia but not in the control group. Differences between experimental groups and the control group were found in the short and medium term. A multimodal treatment is a good method for reducing disability in patients with nonspecific chronic neck pain in the short and medium term.
Military Publications, Index of Test Operations Procedures
1981-10-01
AND RECORDING EQUIPMENT B033862L VOL X ELECTRONIC TEST EQUIPMENT BO33863L VOL XI MAINTENANCE OF ARMY AIRCRAFT; OPERATORS AND CREWMEMBERS MANUALS ...SYSTEMS 718646 6 JUN 68 6-2-186 (L) METEOROLOGICAL EQUIPMENT; METEOROLOGICAL STATIONS, MANUAL OR AUTOMATIC 870954 20 MAR 70 6-2-189 (L) METEOROLOGICAL...69 6-2-250 (L) RELAYS, RADIO 718622 16 APR 69 6-2-262 (L) SUPPRESSORS, VOLTAGE TRANSIENT 720578 MAR 67 6-2-265 (L) SWITCHBOARDS, MANUAL 718647 1 DEC
The effect of experience, simulator-training and biometric feedback on manual ventilation technique.
Lewis, Rebecca; Sherfield, Cerrie A; Fellows, Christopher R; Burrow, Rachel; Young, Iain; Dugdale, Alex
2017-05-01
To determine the frequency of provision and main providers (veterinary surgeons, nurses or trainees) of manual ventilation in UK veterinary practices. Furthermore, to determine the variation in peak inspiratory (inflation) pressure (PIP), applied to a lung model during manual ventilation, by three different groups of operators (inexperienced, experienced and specialist), before and after training. Questionnaire survey, lung model simulator development and prospective testing. Postal questionnaires were sent to 100 randomly selected veterinary practices. The lung model simulator was manually ventilated in a staged process over 3 weeks, with and without real-time biometric feedback (PIP display), by three groups of volunteer operators: inexperienced, experienced and specialist. The questionnaires determined that veterinary nurses were responsible for providing the majority of manual ventilation in veterinary practices, mainly drawing on theoretical knowledge rather than any specific training. Thoracic surgery and apnoea were the main reasons for provision of manual ventilation. Specialists performed well when manually ventilating the lung model, regardless of feedback training. Both inexperienced and experienced operators showed significant improvement in technique when using the feedback training tool: variation in PIP decreased significantly until operators provided manual ventilation at PIPs within the defined optimum range. Preferences for different forms of feedback (graphical, numerical or scale display), revealed that the operators' choice was not always the method which gave least variation in PIP. This study highlighted a need for training in manual ventilation at an early stage in veterinary and veterinary nursing careers and demonstrated how feedback is important in the process of experiential learning. A manometer device which can provide immediate feedback during training, or indeed in a real clinical setting, should improve patient safety. Copyright © 2017 Association of Veterinary Anaesthetists and American College of Veterinary Anesthesia and Analgesia. Published by Elsevier Ltd. All rights reserved.
Computational Knee Ligament Modeling Using Experimentally Determined Zero-Load Lengths
Bloemker, Katherine H; Guess, Trent M; Maletsky, Lorin; Dodd, Kevin
2012-01-01
This study presents a subject-specific method of determining the zero-load lengths of the cruciate and collateral ligaments in computational knee modeling. Three cadaver knees were tested in a dynamic knee simulator. The cadaver knees also underwent manual envelope of motion testing to find their passive range of motion in order to determine the zero-load lengths for each ligament bundle. Computational multibody knee models were created for each knee and model kinematics were compared to experimental kinematics for a simulated walk cycle. One-dimensional non-linear spring damper elements were used to represent cruciate and collateral ligament bundles in the knee models. This study found that knee kinematics were highly sensitive to altering of the zero-load length. The results also suggest optimal methods for defining each of the ligament bundle zero-load lengths, regardless of the subject. These results verify the importance of the zero-load length when modeling the knee joint and verify that manual envelope of motion measurements can be used to determine the passive range of motion of the knee joint. It is also believed that the method described here for determining zero-load length can be used for in vitro or in vivo subject-specific computational models. PMID:22523522
NASA Technical Reports Server (NTRS)
Knox, Charles E.
1993-01-01
A piloted simulation study was conducted to examine the requirements for using electromechanical flight instrumentation to provide situation information and flight guidance for manually controlled flight along curved precision approach paths to a landing. Six pilots were used as test subjects. The data from these tests indicated that flight director guidance is required for the manually controlled flight of a jet transport airplane on curved approach paths. Acceptable path tracking performance was attained with each of the three situation information algorithms tested. Approach paths with both multiple sequential turns and short final path segments were evaluated. Pilot comments indicated that all the approach paths tested could be used in normal airline operations.
Resource Manual: Handicapped Children Birth to Five. Part 2.
ERIC Educational Resources Information Center
Leslie, Lin; And Others
The resource manual, in two parts, provides a compilation of methods for enhancing the development of handicapped children from birth to 5 years in the areas of motor, communication, cognition, self help, and social skills. The manual is intended to aid in (1) assessing and identifying target behaviors to be achieved, (2) identifying methods for…
NASA Technical Reports Server (NTRS)
Hartle, M.; McKnight, R. L.
2000-01-01
This manual is a combination of a user manual, theory manual, and programmer manual. The reader is assumed to have some previous exposure to the finite element method. This manual is written with the idea that the CSTEM (Coupled Structural Thermal Electromagnetic-Computer Code) user needs to have a basic understanding of what the code is actually doing in order to properly use the code. For that reason, the underlying theory and methods used in the code are described to a basic level of detail. The manual gives an overview of the CSTEM code: how the code came into existence, a basic description of what the code does, and the order in which it happens (a flowchart). Appendices provide a listing and very brief description of every file used by the CSTEM code, including the type of file it is, what routine regularly accesses the file, and what routine opens the file, as well as special features included in CSTEM.
Ranking of physiotherapeutic evaluation methods as outcome measures of stifle functionality in dogs.
Hyytiäinen, Heli K; Mölsä, Sari H; Junnila, Jouni T; Laitinen-Vapaavuori, Outi M; Hielm-Björkman, Anna K
2013-04-08
Various physiotherapeutic evaluation methods are used to assess the functionality of dogs with stifle problems. Neither validity nor sensitivity of these methods has been investigated. This study aimed to determine the most valid and sensitive physiotherapeutic evaluation methods for assessing functional capacity in hind limbs of dogs with stifle problems and to serve as a basis for developing an indexed test for these dogs. A group of 43 dogs with unilateral surgically treated cranial cruciate ligament deficiency and osteoarthritic findings was used to test different physiotherapeutic evaluation methods. Twenty-one healthy dogs served as the control group and were used to determine normal variation in static weight bearing and range of motion.The protocol consisted of 14 different evaluation methods: visual evaluation of lameness, visual evaluation of diagonal movement, visual evaluation of functional active range of motion and difference in thrust of hind limbs via functional tests (sit-to-move and lie-to-move), movement in stairs, evaluation of hind limb muscle atrophy, manual evaluation of hind limb static weight bearing, quantitative measurement of static weight bearing of hind limbs with bathroom scales, and passive range of motion of hind limb stifle (flexion and extension) and tarsal (flexion and extension) joints using a universal goniometer. The results were compared with those from an orthopaedic examination, force plate analysis, radiographic evaluation, and a conclusive assessment. Congruity of the methods was assessed with a combination of three statistical approaches (Fisher's exact test and two differently calculated proportions of agreeing observations), and the components were ranked from best to worst. Sensitivities of all of the physiotherapeutic evaluation methods against each standard were calculated. Evaluation of asymmetry in a sitting and lying position, assessment of muscle atrophy, manual and measured static weight bearing, and measurement of stifle passive range of motion were the most valid and sensitive physiotherapeutic evaluation methods. Ranking of the various physiotherapeutic evaluation methods was accomplished. Several of these methods can be considered valid and sensitive when examining the functionality of dogs with stifle problems.
Ranking of physiotherapeutic evaluation methods as outcome measures of stifle functionality in dogs
2013-01-01
Background Various physiotherapeutic evaluation methods are used to assess the functionality of dogs with stifle problems. Neither validity nor sensitivity of these methods has been investigated. This study aimed to determine the most valid and sensitive physiotherapeutic evaluation methods for assessing functional capacity in hind limbs of dogs with stifle problems and to serve as a basis for developing an indexed test for these dogs. A group of 43 dogs with unilateral surgically treated cranial cruciate ligament deficiency and osteoarthritic findings was used to test different physiotherapeutic evaluation methods. Twenty-one healthy dogs served as the control group and were used to determine normal variation in static weight bearing and range of motion. The protocol consisted of 14 different evaluation methods: visual evaluation of lameness, visual evaluation of diagonal movement, visual evaluation of functional active range of motion and difference in thrust of hind limbs via functional tests (sit-to-move and lie-to-move), movement in stairs, evaluation of hind limb muscle atrophy, manual evaluation of hind limb static weight bearing, quantitative measurement of static weight bearing of hind limbs with bathroom scales, and passive range of motion of hind limb stifle (flexion and extension) and tarsal (flexion and extension) joints using a universal goniometer. The results were compared with those from an orthopaedic examination, force plate analysis, radiographic evaluation, and a conclusive assessment. Congruity of the methods was assessed with a combination of three statistical approaches (Fisher’s exact test and two differently calculated proportions of agreeing observations), and the components were ranked from best to worst. Sensitivities of all of the physiotherapeutic evaluation methods against each standard were calculated. Results Evaluation of asymmetry in a sitting and lying position, assessment of muscle atrophy, manual and measured static weight bearing, and measurement of stifle passive range of motion were the most valid and sensitive physiotherapeutic evaluation methods. Conclusions Ranking of the various physiotherapeutic evaluation methods was accomplished. Several of these methods can be considered valid and sensitive when examining the functionality of dogs with stifle problems. PMID:23566355
How to Write Effective Procedure Manuals.
ERIC Educational Resources Information Center
Wold, Geoffrey H.
1987-01-01
Describes six key guidelines for developing usable procedure manuals, including defining the audience; designing a standard format; preparing an outline; using a clear, concise writing style; testing the procedures; and "finalizing" the product with indices, glossaries, appendices, and section tabs. Well-written manuals can increase…
Ichikawa, Tamaki; Kitanosono, Takashi; Koizumi, Jun; Ogushi, Yoichi; Tanaka, Osamu; Endo, Jun; Hashimoto, Takeshi; Kawada, Shuichi; Saito, Midori; Kobayashi, Makiko; Imai, Yutaka
2007-12-20
We evaluated the usefulness of radiological reporting that combines continuous speech recognition (CSR) and error correction by transcriptionists. Four transcriptionists (two with more than 10 years' and two with less than 3 months' transcription experience) listened to the same 100 dictation files and created radiological reports using conventional transcription and a method that combined CSR with manual error correction by the transcriptionists. We compared the 2 groups using the 2 methods for accuracy and report creation time and evaluated the transcriptionists' inter-personal dependence on accuracy rate and report creation time. We used a CSR system that did not require the training of the system to recognize the user's voice. We observed no significant difference in accuracy between the 2 groups and 2 methods that we tested, though transcriptionists with greater experience transcribed faster than those with less experience using conventional transcription. Using the combined method, error correction speed was not significantly different between two groups of transcriptionists with different levels of experience. Combining CSR and manual error correction by transcriptionists enabled convenient and accurate radiological reporting.
Ballanger, Bénédicte; Tremblay, Léon; Sgambato-Faure, Véronique; Beaudoin-Gobert, Maude; Lavenne, Franck; Le Bars, Didier; Costes, Nicolas
2013-08-15
MRI templates and digital atlases are needed for automated and reproducible quantitative analysis of non-human primate PET studies. Segmenting brain images via multiple atlases outperforms single-atlas labelling in humans. We present a set of atlases manually delineated on brain MRI scans of the monkey Macaca fascicularis. We use this multi-atlas dataset to evaluate two automated methods in terms of accuracy, robustness and reliability in segmenting brain structures on MRI and extracting regional PET measures. Twelve individual Macaca fascicularis high-resolution 3DT1 MR images were acquired. Four individual atlases were created by manually drawing 42 anatomical structures, including cortical and sub-cortical structures, white matter regions, and ventricles. To create the MRI template, we first chose one MRI to define a reference space, and then performed a two-step iterative procedure: affine registration of individual MRIs to the reference MRI, followed by averaging of the twelve resampled MRIs. Automated segmentation in native space was obtained in two ways: 1) Maximum probability atlases were created by decision fusion of two to four individual atlases in the reference space, and transformation back into the individual native space (MAXPROB)(.) 2) One to four individual atlases were registered directly to the individual native space, and combined by decision fusion (PROPAG). Accuracy was evaluated by computing the Dice similarity index and the volume difference. The robustness and reproducibility of PET regional measurements obtained via automated segmentation was evaluated on four co-registered MRI/PET datasets, which included test-retest data. Dice indices were always over 0.7 and reached maximal values of 0.9 for PROPAG with all four individual atlases. There was no significant mean volume bias. The standard deviation of the bias decreased significantly when increasing the number of individual atlases. MAXPROB performed better when increasing the number of atlases used. When all four atlases were used for the MAXPROB creation, the accuracy of morphometric segmentation approached that of the PROPAG method. PET measures extracted either via automatic methods or via the manually defined regions were strongly correlated, with no significant regional differences between methods. Intra-class correlation coefficients for test-retest data were over 0.87. Compared to single atlas extractions, multi-atlas methods improve the accuracy of region definition. They also perform comparably to manually defined regions for PET quantification. Multiple atlases of Macaca fascicularis brains are now available and allow reproducible and simplified analyses. Copyright © 2013 Elsevier Inc. All rights reserved.
Tooth-size discrepancy: A comparison between manual and digital methods
Correia, Gabriele Dória Cabral; Habib, Fernando Antonio Lima; Vogel, Carlos Jorge
2014-01-01
Introduction Technological advances in Dentistry have emerged primarily in the area of diagnostic tools. One example is the 3D scanner, which can transform plaster models into three-dimensional digital models. Objective This study aimed to assess the reliability of tooth size-arch length discrepancy analysis measurements performed on three-dimensional digital models, and compare these measurements with those obtained from plaster models. Material and Methods To this end, plaster models of lower dental arches and their corresponding three-dimensional digital models acquired with a 3Shape R700T scanner were used. All of them had lower permanent dentition. Four different tooth size-arch length discrepancy calculations were performed on each model, two of which by manual methods using calipers and brass wire, and two by digital methods using linear measurements and parabolas. Results Data were statistically assessed using Friedman test and no statistically significant differences were found between the two methods (P > 0.05), except for values found by the linear digital method which revealed a slight, non-significant statistical difference. Conclusions Based on the results, it is reasonable to assert that any of these resources used by orthodontists to clinically assess tooth size-arch length discrepancy can be considered reliable. PMID:25279529
10 CFR 4.124 - Employment criteria.
Code of Federal Regulations, 2011 CFR
2011-01-01
... sensory, manual, or speaking skills, the test results accurately reflect the applicant's or employee's job skills, aptitude, or whatever other factor the test purports to measure, rather than reflecting the applicant's or employee's impaired sensory, manual, or speaking skills (except where those skills are the...
10 CFR 4.124 - Employment criteria.
Code of Federal Regulations, 2010 CFR
2010-01-01
... sensory, manual, or speaking skills, the test results accurately reflect the applicant's or employee's job skills, aptitude, or whatever other factor the test purports to measure, rather than reflecting the applicant's or employee's impaired sensory, manual, or speaking skills (except where those skills are the...
Reproducibility of myelin content-based human habenula segmentation at 3 Tesla.
Kim, Joo-Won; Naidich, Thomas P; Joseph, Joshmi; Nair, Divya; Glasser, Matthew F; O'halloran, Rafael; Doucet, Gaelle E; Lee, Won Hee; Krinsky, Hannah; Paulino, Alejandro; Glahn, David C; Anticevic, Alan; Frangou, Sophia; Xu, Junqian
2018-03-26
In vivo morphological study of the human habenula, a pair of small epithalamic nuclei adjacent to the dorsomedial thalamus, has recently gained significant interest for its role in reward and aversion processing. However, segmenting the habenula from in vivo magnetic resonance imaging (MRI) is challenging due to the habenula's small size and low anatomical contrast. Although manual and semi-automated habenula segmentation methods have been reported, the test-retest reproducibility of the segmented habenula volume and the consistency of the boundaries of habenula segmentation have not been investigated. In this study, we evaluated the intra- and inter-site reproducibility of in vivo human habenula segmentation from 3T MRI (0.7-0.8 mm isotropic resolution) using our previously proposed semi-automated myelin contrast-based method and its fully-automated version, as well as a previously published manual geometry-based method. The habenula segmentation using our semi-automated method showed consistent boundary definition (high Dice coefficient, low mean distance, and moderate Hausdorff distance) and reproducible volume measurement (low coefficient of variation). Furthermore, the habenula boundary in our semi-automated segmentation from 3T MRI agreed well with that in the manual segmentation from 7T MRI (0.5 mm isotropic resolution) of the same subjects. Overall, our proposed semi-automated habenula segmentation showed reliable and reproducible habenula localization, while its fully-automated version offers an efficient way for large sample analysis. © 2018 Wiley Periodicals, Inc.
Spade, Daniel J; Bai, Cathy Yue; Lambright, Christy; Conley, Justin M; Boekelheide, Kim; Gray, L Earl
2018-06-15
In utero exposure to certain phthalate esters results in testicular toxicity, characterized at the tissue level by induction of multinucleated germ cells (MNGs) in rat, mouse, and human fetal testis. Phthalate exposures also result in a decrease in testicular testosterone in rats. The anti-androgenic effects of phthalates have been more thoroughly quantified than testicular pathology due to the significant time requirement associated with manual counting of MNGs on histological sections. An automated counting method was developed in ImageJ to quantify MNGs in digital images of hematoxylin-stained rat fetal testis tissue sections. Timed pregnant Sprague Dawley rats were exposed by daily oral gavage from gestation day 17 to 21 with one of eight phthalate test compounds or corn oil vehicle. Both the manual counting method and the automated image analysis method identified di-n-butyl phthalate, butyl benzyl phthalate, dipentyl phthalate, and di-(2-ethylhexyl) phthalate as positive for induction of MNGs. Dimethyl phthalate, diethyl phthalate, the brominated phthalate di-(2-ethylhexyl) tetrabromophthalate, and dioctyl terephthalate were negative. The correlation between automated and manual scoring metrics was high (r = 0.923). Results of MNG analysis were consistent with these compounds' anti-androgenic activities, which were confirmed in an ex vivo testosterone production assay. In conclusion, we have developed a reliable image analysis method that can be used to facilitate dose-response studies for the reproducible induction of MNGs by in utero phthalate exposure. Copyright © 2018 Elsevier B.V. All rights reserved.
Comparison of Manual Refraction Versus Autorefraction in 60 Diabetic Retinopathy Patients.
Shirzadi, Keyvan; Shahraki, Kourosh; Yahaghi, Emad; Makateb, Ali; Khosravifard, Keivan
2016-07-27
The purpose of the study was to evaluate the comparison of manual refraction versus autorefraction in diabetic retinopathy patients. The study was conducted at the Be'sat Army Hospital from 2013-2015. In the present study differences between two common refractometry methods (manual refractometry and Auto refractometry) in diagnosis and follow up of retinopathy in patients affected with diabetes is investigated. Our results showed that there is a significant difference in visual acuity score of patients between manual and auto refractometry. Despite this fact, spherical equivalent scores of two methods of refractometry did not show a significant statistical difference in the patients. Although use of manual refraction is comparable with autorefraction in evaluating spherical equivalent scores in diabetic patients affected with retinopathy, but in the case of visual acuity results from these two methods are not comparable.
Wongsritrang, Krongthong; Fueangkamloon, Sumet
2013-09-01
To compare the clinical outcomes and determine the difference in therapeutic pressure between Automatic positive airway pressure (APAP) and polysomnography manual titration. Fifty patients of obstructive sleep apnea (OSA), moderate to severe cases, were randomized into two groups of intervention: 95-percentile pressure derived from APAP titration and an optimal pressure derived from manual titration. Clinical outcomes were assessed before and after four weeks. The average 95-percentile pressure derived from APAP titration was 11.7 +/- 0.3 cmH2O with median mask leak 1.3 L/min. The average optimal pressure derived from manual titration was 8.2 +/- 0.3 cmH2O. Pearson correlation analysis showed weak positive correlation (r = 0.336, p = 0.017). The Epworth Sleepiness Score (ESS), Quality of life tests: PSQI (Pittsburg Sleep Quality Index), and SF-36 (Medical Outcomes Study 36-Item Short-Form Health Survey) were improved significantly in both groups, but there were no statistical significant differences between groups. An APAP titration is an effective method of pressure determination for conventional CPAP therapy and shows no difference in clinical outcomes comparing the standard titration.
A Manual for Teachers to Aid the Understanding and Implementation of Statewide Evaluation.
ERIC Educational Resources Information Center
New Mexico State Dept. of Education, Santa Fe.
A manual is presented to familiarize the teacher with the two major components of the New Mexico evaluation effort: (1) the objective-based procedure and the tests used to measure a school and district's progress toward those objectives, and (2) the statewide testing program which utilizes norm-referenced tests and provides both individual and…
Social Studies Assessment Program: Grade 10 [and] Manual and Scoring Key.
ERIC Educational Resources Information Center
Manitoba Dept. of Education and Training, Winnipeg. Curriculum Development and Implementation Branch.
Designed to assess the success of social studies instruction for students in grade 10 in Manitoba, Canada, this test evaluation instrument contains a manual, a scoring key, and a test. Administered to determine whether students learned important ideas and skills in social studies instruction, the results of the testing will be used to improve…
Solar Heating Systems: Progress Checks & Tests Manual.
ERIC Educational Resources Information Center
Green, Joanne; And Others
This manual contains Progress Checks and Tests for use in a Solar Heating Systems curriculum (see note). It contains master copies of all Progress Checks and Unit Tests accompanying the curriculum, organized by unit. (The master copies are to be duplicated by each school so that adequate copies are available for student use in a self-paced student…
Raman, Pavithra; Raman, Raghav; Newman, Beverley; Venkatraman, Raman; Raman, Bhargav; Robinson, Terry E
2010-12-01
To address potential concern for cumulative radiation exposure with serial spiral chest computed tomography (CT) scans in children with chronic lung disease, we developed an approach to match bronchial airways on low-dose spiral and low-dose high-resolution CT (HRCT) chest images to allow serial comparisons. An automated algorithm matches the position and orientation of bronchial airways obtained from HRCT slices with those in the spiral CT scan. To validate this algorithm, we compared manual matching vs automatic matching of bronchial airways in three pediatric patients. The mean absolute percentage difference between the manually matched spiral CT airway and the index HRCT airways were 9.4 ± 8.5% for the internal diameter measurements, 6.0 ± 4.1% for the outer diameter measurements, and 10.1 ± 9.3% for the wall thickness measurements. The mean absolute percentage difference between the automatically matched spiral CT airway measurements and index HRCT airway measurements were 9.2 ± 8.6% for the inner diameter, 5.8 ± 4.5% for the outer diameter, and 9.9 ± 9.5% for the wall thickness. The overall difference between manual and automated methods was 2.1 ± 1.2%, which was significantly less than the interuser variability of 5.1 ± 4.6% (p<0.05). Tests of equivalence had p<0.05, demonstrating no significant difference between the two methods. The time required for matching was significantly reduced in the automated method (p<0.01) and was as accurate as manual matching, allowing efficient comparison of airways obtained on low-dose spiral CT imaging with low-dose HRCT scans.
Ffuzz: Towards full system high coverage fuzz testing on binary executables.
Zhang, Bin; Ye, Jiaxi; Bi, Xing; Feng, Chao; Tang, Chaojing
2018-01-01
Bugs and vulnerabilities in binary executables threaten cyber security. Current discovery methods, like fuzz testing, symbolic execution and manual analysis, both have advantages and disadvantages when exercising the deeper code area in binary executables to find more bugs. In this paper, we designed and implemented a hybrid automatic bug finding tool-Ffuzz-on top of fuzz testing and selective symbolic execution. It targets full system software stack testing including both the user space and kernel space. Combining these two mainstream techniques enables us to achieve higher coverage and avoid getting stuck both in fuzz testing and symbolic execution. We also proposed two key optimizations to improve the efficiency of full system testing. We evaluated the efficiency and effectiveness of our method on real-world binary software and 844 memory corruption vulnerable programs in the Juliet test suite. The results show that Ffuzz can discover software bugs in the full system software stack effectively and efficiently.
Golbaz, Isabelle; Ahlers, Christian; Goesseringer, Nina; Stock, Geraldine; Geitzenauer, Wolfgang; Prünte, Christian; Schmidt-Erfurth, Ursula Margarethe
2011-03-01
This study compared automatic- and manual segmentation modalities in the retina of healthy eyes using high-definition optical coherence tomography (HD-OCT). Twenty retinas in 20 healthy individuals were examined using an HD-OCT system (Carl Zeiss Meditec, Inc.). Three-dimensional imaging was performed with an axial resolution of 6 μm at a maximum scanning speed of 25,000 A-scans/second. Volumes of 6 × 6 × 2 mm were scanned. Scans were analysed using a matlab-based algorithm and a manual segmentation software system (3D-Doctor). The volume values calculated by the two methods were compared. Statistical analysis revealed a high correlation between automatic and manual modes of segmentation. The automatic mode of measuring retinal volume and the corresponding three-dimensional images provided similar results to the manual segmentation procedure. Both methods were able to visualize retinal and subretinal features accurately. This study compared two methods of assessing retinal volume using HD-OCT scans in healthy retinas. Both methods were able to provide realistic volumetric data when applied to raster scan sets. Manual segmentation methods represent an adequate tool with which to control automated processes and to identify clinically relevant structures, whereas automatic procedures will be needed to obtain data in larger patient populations. © 2009 The Authors. Journal compilation © 2009 Acta Ophthalmol.
LeBa, Thu-Ba; Gugala, Zbigniew; Morris, Randal P; Panchbhavi, Vinod K
2015-06-01
The purpose of this prospective study was to determine whether gravity versus manual external rotation stress testing effectively detects widening of the medial clear space in isolated ankle fractures when compared with the uninjured contralateral side. Manual external rotation stress and gravity stress tests were performed on injured and uninjured ankles of ankle fracture patients in a clinic setting. Medial clear space measurements were recorded and differences between gravity and manual stress views were determined. Twenty consecutive patients with ankle injury were enrolled in the study. When compared with the uninjured side, gravity stress views showed a statistically significant (P = .017) increase in medial clear space widening (1.85 ± 1.07 mm) compared with manual stress view widening (1.35 ± 1.04 mm). This study suggests that gravity stress views are as effective as manual external rotation stress views in detecting medial clear space widening in isolated fibular fractures. Diagnostic, Level II: Prospective, comparative trial. © 2014 The Author(s).
2011-01-01
Background Reprocessing of endoscopes generally requires labour-intensive manual cleaning followed by high-level disinfection in an automated endoscope reprocessor (AER). EVOTECH Endoscope Cleaner and Reprocessor (ECR) is approved for fully automated cleaning and disinfection whereas AERs require manual cleaning prior to the high-level disinfection procedure. The purpose of this economic evaluation was to determine the cost-efficiency of the ECR versus AER methods of endoscopy reprocessing in an actual practice setting. Methods A time and motion study was conducted at a Canadian hospital to collect data on the personnel resources and consumable supplies costs associated with the use of EVOTECH ECR versus manual cleaning followed by AER with Medivators DSD-201. Reprocessing of all endoscopes was observed and timed for both reprocessor types over three days. Laboratory staff members were interviewed regarding the consumption and cost of all disposable supplies and equipment. Exact Wilcoxon rank sum test was used for assessing differences in total cycle reprocessing time. Results Endoscope reprocessing was significantly shorter with the ECR than with manual cleaning followed by AER. The differences in median time were 12.46 minutes per colonoscope (p < 0.0001), 6.31 minutes per gastroscope (p < 0.0001), and 5.66 minutes per bronchoscope (p = 0.0040). Almost 2 hours of direct labour time was saved daily with the ECR. The total per cycle cost of consumables and labour for maintenance was slightly higher for EVOTECH ECR versus manual cleaning followed by AER ($8.91 versus $8.31, respectively). Including the cost of direct labour time consumed in reprocessing scopes, the per cycle and annual costs of using the EVOTECH ECR was less than the cost of manual cleaning followed by AER disinfection ($11.50 versus $11.88). Conclusions The EVOTECH ECR was more efficient and less costly to use for the reprocessing of endoscopes than manual cleaning followed by AER disinfection. Although the cost of consumable supplies required to reprocess endoscopes with EVOTECH ECR was slightly higher, the value of the labour time saved with EVOTECH ECR more than offset the additional consumables cost. The increased efficiency with EVOTECH ECR could lead to even further cost-savings by shifting endoscopy laboratory personnel responsibilities but further study is required. PMID:21967345
Elias, Nassim Chamel; Goyos, Celso; Saunders, Muriel; Saunders, Richard
2008-01-01
The objective of this study was to teach manual signs through an automated matching-to-sample procedure and to test for the emergence of new conditional relations and imitative behaviors. Seven adults with mild to severe mental retardation participated. Four were also hearing impaired. Relations between manual signs (set A) and pictures (set B) were initially taught, followed by the training of corresponding printed words (set C) and pictures (set B). Further presentations of conditional discriminations tested for the emergence of AC, followed by tests for the emergence of imitative signing behavior (D) in the presence of either pictures (B) or printed words (C). Each stimulus set was comprised of 9 elements. The stimuli were still pictures, printed words, and dynamic presentations of manual signs. A pretest was conducted to determine which signs the participants could make pre-experimentally. Teaching was arranged in a multiple baseline design across 3 groups of 3 words each. The purpose of the present study was to determine whether participants would emit manual signs in expressive signs tests as a result of observation (video modeling) during match-to-sample training in the absence of explicit training. Five of the 7 subjects passed tests of emergence and emitted at least 50% of the signs. Two were hearing impaired with signing experience, and 3 were not hearing impaired and had no signing experience. Thus, observation of video recorded manual signs in a matching-to-sample training procedure was effective at establishing some signs by adults with mental retardation. PMID:22477400
NASA Astrophysics Data System (ADS)
Pena-Verdeal, Hugo; Garcia-Resua, Carlos; Yebra-Pimentel, Eva; Giraldez, Maria J.
2017-08-01
Purpose: Different lower tear meniscus parameters can be clinical assessed on dry eye diagnosis. The aim of this study was to propose and analyse the variability of a semi-automatic method for measuring lower tear meniscus central area (TMCA) by using open source software. Material and methods: On a group of 105 subjects, one video of the lower tear meniscus after fluorescein instillation was generated by a digital camera attached to a slit-lamp. A short light beam (3x5 mm) with moderate illumination in the central portion of the meniscus (6 o'clock) was used. Images were extracted from each video by a masked observer. By using an open source software based on Java (NIH ImageJ), a further observer measured in a masked and randomized order the TMCA in the short light beam illuminated area by two methods: (1) manual method, where TMCA images was "manually" measured; (2) semi-automatic method, where TMCA images were transformed in an 8-bit-binary image, then holes inside this shape were filled and on the isolated shape, the area size was obtained. Finally, both measurements, manual and semi-automatic, were compared. Results: Paired t-test showed no statistical difference between both techniques results (p = 0.102). Pearson correlation between techniques show a significant positive near to perfect correlation (r = 0.99; p < 0.001). Conclusions: This study showed a useful tool to objectively measure the frontal central area of the meniscus in photography by free open source software.
Nyberg, Richard Edward; Russell Smith, A
2013-01-01
Spinal motion palpation (SMP) is a standard component of a manual therapy examination despite questionable reliability. The present research is inconclusive as to the relevance of the findings from SMP, with respect to the patient’s pain complaints. Differences in the testing methods and interpretation of spinal mobility testing are problematic. If SMP is to be a meaningful component of a spinal examination, the methods for testing and interpretation must be carefully scrutinized. The intent of this narrative review is to facilitate a better understanding of how SMP should provide the examiner with relevant information for assessment and treatment of patients with spinal pain disorders. The concept of just noticeable difference is presented and applied to SMP as a suggestion for determining the neutral zone behavior of a spinal segment. In addition, the use of a lighter, or more passive receptive palpation technique, is considered as a means for increasing tactile discrimination of spinal movement behavior. Further understanding of the scientific basis of testing SMP may improve intra- and inter-examiner reliability. The significance of the findings from SMP should be considered in context of the patient’s functional problem. Methodological changes may be indicated for the performance of SMP techniques, such as central posterior-anterior (PA) pressure and passive intervertebral motion tests, in order to improve reliability. Instructors of manual therapy involved in teaching SMP should be knowledgeable of the neurophysiological processes of touch sensation so as to best advise students in the application of the various testing techniques. PMID:24421627
Vocational Education Readiness Test Manual.
ERIC Educational Resources Information Center
Thomas, Edward L.; And Others
This manual provides vocational instructors in public schools with standardized procedures in the form of a Vocational Education Readiness Test (VERT) for assessing the vocational potential of educable mentally handicapped (EMR) secondary school students. The various stages of VERT's development are traced: (1) visits with vocational trade…
IERL-RTP PROCEDURES MANUAL: LEVEL 1 ENVIRONMENTAL ASSESSMENT BIOLOGICAL TESTS
The manual gives revised procedures for Level 1 environmental assessment biological tests, and supersedes the first edition, EPA-600/7-77-043 (NTIS No. PB 268484), published in April 1977. The revised biological procedures complement the Level 1 chemical and physical procedures p...
Applicator Training Manual for: Aerial Application of Pesticides.
ERIC Educational Resources Information Center
Overhults, Douglas G.
This training manual discusses both the advantages and limitations of aerial application of pesticides. Other topics included are: agricultural aircraft equipment, dispersal accessories, drift control, calibration, spray testing, granular materials testing, operations, and personal safety. Safety check lists are given for pilots, ground crew, and…
Regents Examinations and Competency Tests: School Administrator's Manual. 1981 Edition.
ERIC Educational Resources Information Center
New York State Education Dept., Albany. Bureau of Elementary and Secondary Educational Testing.
Intended for use by school administrators, guidance counselors, teachers, and proctors, this manual contains general information on Regents examinations and competency tests. Specifically, the regulations and procedures for ordering, administering, and rating these examinations are described. Information is also included about the competency…
Regents Examinations & Competency Tests: School Administrator's Manual. 1983 Edition.
ERIC Educational Resources Information Center
New York State Education Dept., Albany. Bureau of Elementary and Secondary Testing Programs.
Intended for use by school administrators, guidance counselors, teachers, and proctors, this manual contains general information on Regents examinations and competency tests. Specifically, the regulations and procedures for ordering, administering, rating, and reporting results of these examinations are described. Information is also included…
Comparison of tongue interface with keyboard for control of an assistive robotic arm.
Struijk, Lotte N S Andreasen; Lontis, Romulus
2017-07-01
This paper demonstrates how an assistive 6 DoF robotic arm with a gripper can be controlled manually using a tongue interface. The proposed method suggests that it possible for a user to manipulate the surroundings with his or her tongue using the inductive tongue control system as deployed in this study. The sensors of an inductive tongue-computer interface were mapped to the Cartesian control of an assistive robotic arm. The resulting control system was tested manually in order to compare manual control of the robot using a standard keyboard and using the tongue interface. Two healthy subjects controlled the robotic arm to precisely move a bottle of water from one location to another. The results shows that the tongue interface was able to fully control the robotic arm in a similar manner as the standard keyboard resulting in the same number of successful manipulations and an average increase in task duration of up to 30% as compared with the standard keyboard.
Field of dreamers and dreamed-up fields: functional and fake perimetry.
Thompson, J C; Kosmorsky, G S; Ellis, B D
1996-01-01
Hysterical and malingering patients can manifest visual field defects on perimetry (visual field testing), including defects suggestive of true visual pathway pathology. It has been shown that control subjects can easily imitate some pathologic defects with automated, computed perimetry. The authors sought to determine whether subjects could imitate the same pathologic defect with manual and automated perimetry. Six subjects posed as patients with neurologic problems. They had manual perimetry with both an experienced and inexperienced technician followed by automated perimetry. They were later interviewed about the methods of the technicians and the difficulty of the exercise. Four of six subjects easily imitated the assigned defects with both technicians on manual perimetry and with automated perimetry. These included quadrantic, altitudinal, hemianopic, and enlarged blind-spot defects. Two subjects who were assigned cecocentral and paracentral scotomas instead produced enlarged blind spots by manual perimetry and defects suggestive of chiasmal pathology by automated perimetry. Paradoxically, some subjects found that experienced technicians were easier to fool than inexperienced technicians because of the systematic way in which experienced technicians defined defects. With minimal coaching, some subjects can imitate visual fields with enlarged blind spots, quadrantic, hemianopic, and altitudinal defects with ease and reproducibility by both automated and manual perimetry. Cecocentral and paracentral scotomas are harder to imitate but may be mistaken as representing chiasmal pathology. Paradoxically, experienced technicians may not be better at detecting hysterical or malingering individuals.
Accuracy of localization of prostate lesions using manual palpation and ultrasound elastography
NASA Astrophysics Data System (ADS)
Kut, Carmen; Schneider, Caitlin; Carter-Monroe, Naima; Su, Li-Ming; Boctor, Emad; Taylor, Russell
2009-02-01
Purpose: To compare the accuracy of detecting tumor location and size in the prostate using both manual palpation and ultrasound elastography (UE). Methods: Tumors in the prostate were simulated using both synthetic and ex vivo tissue phantoms. 25 participants were asked to provide the presence, size and depth of these simulated lesions using manual palpation and UE. Ultrasound images were captured using a laparoscopic ultrasound probe, fitted with a Gore-Tetrad transducer with frequency of 7.5 MHz and a RF capture depth of 4-5 cm. A MATLAB GUI application was employed to process the RF data for ex vivo phantoms, and to generate UE images using a cross-correlation algorithm. Ultrasonix software was used to provide real time elastography during laparoscopic palpation of the synthetic phantoms. Statistical analyses were performed based on a two-tailed, student t-test with α = 0.05. Results: UE displays both a higher accuracy and specificity in tumor detection (sensitivity = 84%, specificity = 74%). Tumor diameters and depths are better estimated using ultrasound elastography when compared with manual palpation. Conclusions: Our results indicate that UE has strong potential in assisting surgeons to intra-operatively evaluate the tumor depth and size. We have also demonstrated that ultrasound elastography can be implemented in a laparoscopic environment, in which manual palpation would not be feasible. With further work, this application can provide accurate and clinically relevant information for surgeons during prostate resection.
Fully Automatic Segmentation of Fluorescein Leakage in Subjects With Diabetic Macular Edema
Rabbani, Hossein; Allingham, Michael J.; Mettu, Priyatham S.; Cousins, Scott W.; Farsiu, Sina
2015-01-01
Purpose. To create and validate software to automatically segment leakage area in real-world clinical fluorescein angiography (FA) images of subjects with diabetic macular edema (DME). Methods. Fluorescein angiography images obtained from 24 eyes of 24 subjects with DME were retrospectively analyzed. Both video and still-frame images were obtained using a Heidelberg Spectralis 6-mode HRA/OCT unit. We aligned early and late FA frames in the video by a two-step nonrigid registration method. To remove background artifacts, we subtracted early and late FA frames. Finally, after postprocessing steps, including detection and inpainting of the vessels, a robust active contour method was utilized to obtain leakage area in a 1500-μm-radius circular region centered at the fovea. Images were captured at different fields of view (FOVs) and were often contaminated with outliers, as is the case in real-world clinical imaging. Our algorithm was applied to these images with no manual input. Separately, all images were manually segmented by two retina specialists. The sensitivity, specificity, and accuracy of manual interobserver, manual intraobserver, and automatic methods were calculated. Results. The mean accuracy was 0.86 ± 0.08 for automatic versus manual, 0.83 ± 0.16 for manual interobserver, and 0.90 ± 0.08 for manual intraobserver segmentation methods. Conclusions. Our fully automated algorithm can reproducibly and accurately quantify the area of leakage of clinical-grade FA video and is congruent with expert manual segmentation. The performance was reliable for different DME subtypes. This approach has the potential to reduce time and labor costs and may yield objective and reproducible quantitative measurements of DME imaging biomarkers. PMID:25634978
Smits, Loek P.; van Wijk, Diederik F.; Duivenvoorden, Raphael; Xu, Dongxiang; Yuan, Chun; Stroes, Erik S.; Nederveen, Aart J.
2016-01-01
Purpose To study the interscan reproducibility of manual versus automated segmentation of carotid artery plaque components, and the agreement between both methods, in high and lower quality MRI scans. Methods 24 patients with 30–70% carotid artery stenosis were planned for 3T carotid MRI, followed by a rescan within 1 month. A multicontrast protocol (T1w,T2w, PDw and TOF sequences) was used. After co-registration and delineation of the lumen and outer wall, segmentation of plaque components (lipid-rich necrotic cores (LRNC) and calcifications) was performed both manually and automated. Scan quality was assessed using a visual quality scale. Results Agreement for the detection of LRNC (Cohen’s kappa (k) is 0.04) and calcification (k = 0.41) between both manual and automated segmentation methods was poor. In the high-quality scans (visual quality score ≥ 3), the agreement between manual and automated segmentation increased to k = 0.55 and k = 0.58 for, respectively, the detection of LRNC and calcification larger than 1 mm2. Both manual and automated analysis showed good interscan reproducibility for the quantification of LRNC (intraclass correlation coefficient (ICC) of 0.94 and 0.80 respectively) and calcified plaque area (ICC of 0.95 and 0.77, respectively). Conclusion Agreement between manual and automated segmentation of LRNC and calcifications was poor, despite a good interscan reproducibility of both methods. The agreement between both methods increased to moderate in high quality scans. These findings indicate that image quality is a critical determinant of the performance of both manual and automated segmentation of carotid artery plaque components. PMID:27930665
Ravikumar, Ke; Liu, Haibin; Cohn, Judith D; Wall, Michael E; Verspoor, Karin
2012-10-05
We propose a method for automatic extraction of protein-specific residue mentions from the biomedical literature. The method searches text for mentions of amino acids at specific sequence positions and attempts to correctly associate each mention with a protein also named in the text. The methods presented in this work will enable improved protein functional site extraction from articles, ultimately supporting protein function prediction. Our method made use of linguistic patterns for identifying the amino acid residue mentions in text. Further, we applied an automated graph-based method to learn syntactic patterns corresponding to protein-residue pairs mentioned in the text. We finally present an approach to automated construction of relevant training and test data using the distant supervision model. The performance of the method was assessed by extracting protein-residue relations from a new automatically generated test set of sentences containing high confidence examples found using distant supervision. It achieved a F-measure of 0.84 on automatically created silver corpus and 0.79 on a manually annotated gold data set for this task, outperforming previous methods. The primary contributions of this work are to (1) demonstrate the effectiveness of distant supervision for automatic creation of training data for protein-residue relation extraction, substantially reducing the effort and time involved in manual annotation of a data set and (2) show that the graph-based relation extraction approach we used generalizes well to the problem of protein-residue association extraction. This work paves the way towards effective extraction of protein functional residues from the literature.
40 CFR 53.2 - General requirements for a reference method determination.
Code of Federal Regulations, 2010 CFR
2010-07-01
...) Manual methods—(1) Sulfur dioxide (SO 2 ) and lead. For measuring SO2 and lead, appendices A and G of part 50 of this chapter specify unique manual FRM for measuring these pollutants. Except as provided in § 53.16, other manual methods for SO2 and lead will not be considered for FRM determinations under this...
Methods for automatic detection of artifacts in microelectrode recordings.
Bakštein, Eduard; Sieger, Tomáš; Wild, Jiří; Novák, Daniel; Schneider, Jakub; Vostatek, Pavel; Urgošík, Dušan; Jech, Robert
2017-10-01
Extracellular microelectrode recording (MER) is a prominent technique for studies of extracellular single-unit neuronal activity. In order to achieve robust results in more complex analysis pipelines, it is necessary to have high quality input data with a low amount of artifacts. We show that noise (mainly electromagnetic interference and motion artifacts) may affect more than 25% of the recording length in a clinical MER database. We present several methods for automatic detection of noise in MER signals, based on (i) unsupervised detection of stationary segments, (ii) large peaks in the power spectral density, and (iii) a classifier based on multiple time- and frequency-domain features. We evaluate the proposed methods on a manually annotated database of 5735 ten-second MER signals from 58 Parkinson's disease patients. The existing methods for artifact detection in single-channel MER that have been rigorously tested, are based on unsupervised change-point detection. We show on an extensive real MER database that the presented techniques are better suited for the task of artifact identification and achieve much better results. The best-performing classifiers (bagging and decision tree) achieved artifact classification accuracy of up to 89% on an unseen test set and outperformed the unsupervised techniques by 5-10%. This was close to the level of agreement among raters using manual annotation (93.5%). We conclude that the proposed methods are suitable for automatic MER denoising and may help in the efficient elimination of undesirable signal artifacts. Copyright © 2017 Elsevier B.V. All rights reserved.
Zebrowska, Aleksandra; Trybulski, Robert; Roczniok, Robert; Marcol, Wieslaw
2017-08-16
Physical methods are reported to be important for accelerating skeletal muscle regeneration, decreasing muscle soreness, and shortening of the recovery time. The aim of the study was to assess the effect of the physical methods of lymphatic drainage (PMLD) such as manual lymphatic drainage (MLD), the Bodyflow (BF) therapy, and lymphatic drainage by deep oscillation (DO) on postexercise regeneration of the forearm muscles of mixed martial arts (MMA) athletes. Eighty MMA athletes aged 27.5 ± 6.4 years were allocated to 4 groups: MLD, the BF device, DO therapy, and the control group. Blood flow velocity in the cephalic vein was measured with the ultrasound Doppler velocity meter. Maximal strength of the forearm muscles (Fmax), muscle tissue tension, pain threshold, blood lactate concentration (LA), and activity of creatine kinase were measured in all groups at rest, after the muscle fatigue test (post-ex) and then 20 minutes, 24, and 48 hours after the application of PMLD. The muscle fatigue test reduced Fmax in all subjects, but in the groups receiving MLD, DO, and BF significantly higher Fmax was observed at recovery compared with post-ex values. The application of MDL reduced the postexercise blood LA and postexercise muscle tension. The lymphatic drainage methods, whether manual or using electro-stimulation and DO, improve postexercise regeneration of the forearm muscles of MMA athletes. The methods can be an important element of therapeutic management focused on optimizing training effects and reducing the risk of injuries of the combat sports athletes.
An experience of qualified preventive screening: shiraz smart screening software.
Islami Parkoohi, Parisa; Zare, Hashem; Abdollahifard, Gholamreza
2015-01-01
Computerized preventive screening software is a cost effective intervention tool to address non-communicable chronic diseases. Shiraz Smart Screening Software (SSSS) was developed as an innovative tool for qualified screening. It allows simultaneous smart screening of several high-burden chronic diseases and supports reminder notification functionality. The extent in which SSSS affects screening quality is also described. Following software development, preventive screening and annual health examinations of 261 school staff (Medical School of Shiraz, Iran) was carried out in a software-assisted manner. To evaluate the quality of the software-assisted screening, we used quasi-experimental study design and determined coverage, irregular attendance and inappropriateness proportions in relation with the manual and software-assisted screening as well as the corresponding number of requested tests. In manual screening method, 27% of employees were covered (with 94% irregular attendance) while by software-assisted screening, the coverage proportion was 79% (attendance status will clear after the specified time). The frequency of inappropriate screening test requests, before the software implementation, was 41.37% for fasting plasma glucose, 41.37% for lipid profile, 0.84% for occult blood, 0.19% for flexible sigmoidoscopy/colonoscopy, 35.29% for Pap smear, 19.20% for mammography and 11.2% for prostate specific antigen. All of the above were corrected by the software application. In total, 366 manual screening and 334 software-assisted screening tests were requested. SSSS is an innovative tool to improve the quality of preventive screening plans in terms of increased screening coverage, reduction in inappropriateness and the total number of requested tests.
Koehl, Bérengère; Sommet, Julie; Holvoet, Laurent; Abdoul, Hendy; Boizeau, Priscilla; Ithier, Ghislaine; Missud, Florence; Couque, Nathalie; Verlhac, Suzanne; Voultoury, Pauline; Sellami, Fatiha; Baruchel, André; Benkerrou, Malika
2016-05-01
Chronic exchange transfusion is effective for primary and secondary prevention of stroke in children with sickle cell anemia (SCA). Erythrocytapheresis is recognized to be the most efficient approach; however, it is not widely implemented and is not suitable for all patients. The aim of our study was to compare automated exchange transfusion (AET) with our manual method of exchange transfusion and, in particular, to evaluate the efficacy, safety, and cost of our manual method. Thirty-nine SCA children with stroke and/or abnormal findings on transcranial Doppler were included in the study. We retrospectively analyzed 1353 exchange sessions, including 333 sessions of AET and 1020 sessions of manual exchange transfusion (MET). Both methods were well tolerated. The median decrease in hemoglobin (Hb)S per session was 21.5% with AET and 18.8% with our manual method (p < 0.0001) with no major increase in red blood cell consumption. Iron overload was well controlled, even with the manual method, with a median (interquartile range) ferritin level of 312 (152-994) µg/L after 24 months of transfusions. The main differences in annual cost relate to equipment costs, which were 74 times higher with the automated method. Our study shows that continuous MET has comparable efficacy to the automated method in terms of stroke prevention, decrease in HbS, and iron overload prevention. It is feasible in all hospital settings and is often combined with AET successively over time. © 2016 AABB.
Computational Methods for Analyzing Health News Coverage
ERIC Educational Resources Information Center
McFarlane, Delano J.
2011-01-01
Researchers that investigate the media's coverage of health have historically relied on keyword searches to retrieve relevant health news coverage, and manual content analysis methods to categorize and score health news text. These methods are problematic. Manual content analysis methods are labor intensive, time consuming, and inherently…
NASA Astrophysics Data System (ADS)
Peterson, Karl
Since the discovery in the late 1930s that air entrainment can improve the durability of concrete, it has been important for people to know the quantity, spacial distribution, and size distribution of the air-voids in their concrete mixes in order to ensure a durable final product. The task of air-void system characterization has fallen on the microscopist, who, according to a standard test method laid forth by the American Society of Testing and Materials, must meticulously count or measure about a thousand air-voids per sample as exposed on a cut and polished cross-section of concrete. The equipment used to perform this task has traditionally included a stereomicroscope, a mechanical stage, and a tally counter. Over the past 30 years, with the availability of computers and digital imaging, automated methods have been introduced to perform the same task, but using the same basic equipment. The method described here replaces the microscope and mechanical stage with an ordinary flatbed desktop scanner, and replaces the microscopist and tally counter with a personal computer; two pieces of equipment much more readily available than a microscope with a mechanical stage, and certainly easier to find than a person willing to sit for extended periods of time counting air-voids. Most laboratories that perform air-void system characterization typically have cabinets full of prepared samples with corresponding results from manual operators. Proponents of automated methods often take advantage of this fact by analyzing the same samples and comparing the results. A similar iterative approach is described here where scanned images collected from a significant number of samples are analyzed, the results compared to those of the manual operator, and the settings optimized to best approximate the results of the manual operator. The results of this calibration procedure are compared to an alternative calibration procedure based on the more rigorous digital image accuracy assessment methods employed primarily by the remote sensing/satellite imaging community.
Manuals Used in the National Aquatic Resource Surveys
Various manuals are used to communicate the methods and guidelines for the National Aquatic Resource Surveys. The Field Operations Manual: outlines the field protocols that crews will utilize to sample sites.
34 CFR 104.44 - Academic adjustments.
Code of Federal Regulations, 2010 CFR
2010-07-01
... that impairs sensory, manual, or speaking skills as will best ensure that the results of the evaluation..., manual, or speaking skills (except where such skills are the factors that the test purports to measure... students with impaired sensory, manual, or speaking skills. (2) Auxiliary aids may include taped texts...
[Evaluation of cadmium, mercury and lead intake with reproduced weekly food rations].
Marzec, Z; Buliński, R
1991-01-01
In Lublin, Olsztyn, Poznań, Warszawa and Wrocław, weekly food rations characteristic of families other than those of manual workers, with medium incomes, were reproduced. Food rations comprised ca. 90 food products whose average weekly intakes were established consistently with the results of questionnaires of the Chief Census Bureau. Namely, from these results we calculated and prepared the average weekly food rations (from 11 470 g to 14 732 g), in which cadmium, mercury and lead were assayed by the ASA method. These average food rations afforded weekly intakes of 105-147 micrograms Cd, 441-931 micrograms Pb and 50.5-119.0 micrograms Hg. According to these results, the average food rations from the above-mentioned cities are moderately contaminated with the heavy metals tested, because in no case 50% of the provisional tolerable weekly intake (PTWI) were exceeded. The present results are lower than those obtained in the same year for families of manual workers; this is probably due to the fact that in the families of manual workers, as compared with other families, the weight of meals is usually higher. It is noteworthy that in the cities with greater numbers of industrial plants the contents of the metals tested, particularly of mercury and lead, in food are higher.
Standardizing Flow Cytometry Immunophenotyping Analysis from the Human ImmunoPhenotyping Consortium
Finak, Greg; Langweiler, Marc; Jaimes, Maria; Malek, Mehrnoush; Taghiyar, Jafar; Korin, Yael; Raddassi, Khadir; Devine, Lesley; Obermoser, Gerlinde; Pekalski, Marcin L.; Pontikos, Nikolas; Diaz, Alain; Heck, Susanne; Villanova, Federica; Terrazzini, Nadia; Kern, Florian; Qian, Yu; Stanton, Rick; Wang, Kui; Brandes, Aaron; Ramey, John; Aghaeepour, Nima; Mosmann, Tim; Scheuermann, Richard H.; Reed, Elaine; Palucka, Karolina; Pascual, Virginia; Blomberg, Bonnie B.; Nestle, Frank; Nussenblatt, Robert B.; Brinkman, Ryan Remy; Gottardo, Raphael; Maecker, Holden; McCoy, J Philip
2016-01-01
Standardization of immunophenotyping requires careful attention to reagents, sample handling, instrument setup, and data analysis, and is essential for successful cross-study and cross-center comparison of data. Experts developed five standardized, eight-color panels for identification of major immune cell subsets in peripheral blood. These were produced as pre-configured, lyophilized, reagents in 96-well plates. We present the results of a coordinated analysis of samples across nine laboratories using these panels with standardized operating procedures (SOPs). Manual gating was performed by each site and by a central site. Automated gating algorithms were developed and tested by the FlowCAP consortium. Centralized manual gating can reduce cross-center variability, and we sought to determine whether automated methods could streamline and standardize the analysis. Within-site variability was low in all experiments, but cross-site variability was lower when central analysis was performed in comparison with site-specific analysis. It was also lower for clearly defined cell subsets than those based on dim markers and for rare populations. Automated gating was able to match the performance of central manual analysis for all tested panels, exhibiting little to no bias and comparable variability. Standardized staining, data collection, and automated gating can increase power, reduce variability, and streamline analysis for immunophenotyping. PMID:26861911
Anger Management for Parents: The Rethink Method. Program Guide, Parent's Manual, and Videotape.
ERIC Educational Resources Information Center
Institute for Mental Health Initiatives, Washington, DC.
Parents who abuse their children are found to lack adequate knowledge of child development and child rearing, and to exhibit a tendency toward more negative and less positive parent-child interactions and a tendency for anger responses to occur in every day child rearing situations. The Institute for Mental Health Initiatives (IMHI) pilot tested a…
A method for assessing the silvicultural effects of releasing young trees from competition.
P.W. Owsten; M. Greenup; V.A. Davis
1986-01-01
Systematic, long-term measurements of the survival and growth effects of releasing crop trees from competing vegetation are important for evaluating vegetation management treatments in forest plantations. This report details field-tested procedures for use in any type of release treatmentâmechanical, manual, biological, or chemical. The basic concept is to delineate...
Historic Crafts and Skills. Instructor Manual. Historic Skills Series.
ERIC Educational Resources Information Center
Cooper, Jim
Designed for classroom teachers and youth leaders, this self-contained manual contains classroom tested background information, lesson plans, activities, class exercises, tests, suggested visual aids, and references for teaching basic historic crafts and skills to junior high and senior high school students. An introductory section briefly…
22 CFR 217.13 - Employment criteria.
Code of Federal Regulations, 2010 CFR
2010-04-01
... administered to an applicant or employee who has a handicap that impairs sensory, manual, or speaking skills, the test results accurately reflect the applicant's or employee's job skills, aptitude, or whatever... sensory, manual or speaking skills (except where those skills are the factors that the test purports to...
22 CFR 217.13 - Employment criteria.
Code of Federal Regulations, 2011 CFR
2011-04-01
... administered to an applicant or employee who has a handicap that impairs sensory, manual, or speaking skills, the test results accurately reflect the applicant's or employee's job skills, aptitude, or whatever... sensory, manual or speaking skills (except where those skills are the factors that the test purports to...
Evaluation of three methods of platelet labelling.
Mortelmans, L; Verbruggen, A; De Roo, M; Vermylen, J
1986-07-01
The study of the kinetics of labelled platelets makes sense only when the platelets preserve their viability after separation and labelling. The separation and labelling procedures described in the manual of two producers of 111In-oxinate (Amersham, Mallinckrodt) have been evaluated by in vitro aggregation tests. The method of Mallinckrodt diminished the aggregation capacities of the thrombocytes. The labelled platelets with normal in vitro aggregation response (Amersham) were tested in vivo in 11 patients who underwent peripheral bypass surgery. The platelet half-life and the platelet accumulation on bypass grafts were checked one week post-operatively. Because of the poor in vivo response of both methods (exponential half-life curve and bad graft visualization), a third method was optimized in our laboratory with good in vitro and in vivo results in 12 patients.
A method for communication analysis in prosthodontics.
Sondell, K; Söderfeldt, B; Palmqvist, S
1998-02-01
Particularly in prosthodontics, in which the issues of esthetic preferences and possibilities are abundant, improved knowledge about dentist patient communication during clinical encounters is important. Because previous studies on communication used different methods and patient materials, the results are difficult to evaluate. There is, therefore, a need for methodologic development. One method that makes it possible to quantitatively describe different interaction behaviors during clinical encounters is the Roter Method of Interaction Process Analysis (RIAS). Since the method was developed in the USA for use in the medical context, a translation of the method into Swedish and a modification of the categories for use in prosthodontics were necessary. The revised manual was used to code 10 audio recordings of dentist patient encounters at a specialist clinic for prosthodontics. No major alterations of the RIAS manual were made during the translation and modification. The study shows that it is possible to distinguish patterns of communication in audio-recorded dentist patient encounters. The method also made the identification of different interaction profiles possible. These profiles distinguished well among the audio-recorded encounters. The coding procedures were tested for intra-rater reliability and found to be 97% for utterance classification and lambda = 0.76 for categorization definition. It was concluded that the revised RIAS method is applicable in communication studies in prosthodontics.
Reddy, J M V Raghavendra; Latha, Prasanna; Gowda, Basavana; Manvikar, Varadendra; Vijayalaxmi, D Benal; Ponangi, Kalyana Chakravarthi
2014-01-01
Background: Predictable successful endodontic therapy depends on correct diagnosis, effective cleaning, shaping and disinfection of the root canals and adequate obturation. Irrigation serves as a flush to remove debris, tissue solvent and lubricant from the canal irregularities; however these irregularities can restrict the complete debridement of root canal by mechanical instrumentation.Various types of hand and rotary instruments are used for the preparation of the root canal system to obtain debris free canals. The purpose of this study was to evaluate the amount of smear layer and debris removal on canal walls following the using of manual Nickel-Titanium (NiTi) files compared with rotary ProTaperNiTi files using a Scanning Electron Microscope in two individual groups. Materials & Methods: A comparative study consisting of 50 subjects randomized into two groups – 25 subjects in Group A (manual) and 25 subjects in Group B (rotary) was undertaken to investigate and compare the effects of smear layer and debris between manual and rotary NiTi instruments. Chi square test was used to find the significance of smear layer and debris removal in the coronal, middle and apical between Group A and Group B. Results: Both systems of Rotary ProTaperNiTi and manual NiTi files used in the present study, did not create completely clean root canals. Manual NiTi files produced significantly less smear layer and debris compared to Rotary ProTaperNiTi instruments. Rotary instruments were less time consuming when compared to manual instruments. Instrument separation was not found to be significant with both the groups. Conclusions: Both systems of Rotary ProTaperNiTi and manual NiTi files used did not produce completely clean root canals. Manual NiTi files produced significantly less smear layer and debris compared to Rotary protaper instruments. How to cite the article: Reddy JM, Latha P, Gowda B, Manvikar V, Vijayalaxmi DB, Ponangi KC. Smear layer and debris removal using manual Ni-Ti files compared with rotary Protaper Ni-Ti files - An In-Vitro SEM study. J Int Oral Health 2014;6(1):89-94. PMID:24653610
Zeidler-Erdely, Patti C.; Antonini, James M.; Meighan, Terence G.; Young, Shih-Houng; Eye, Tracy J.; Hammer, Mary Ann; Erdely, Aaron
2016-01-01
Pulmonary toxicity studies often use bronchoalveolar lavage (BAL) to investigate potential adverse lung responses to a particulate exposure. The BAL cellular fraction is counted, using automated (i.e. Coulter Counter®), flow cytometry or manual (i.e. hemocytometer) methods, to determine inflammatory cell influx. The goal of the study was to compare the different counting methods to determine which is optimal for examining BAL cell influx after exposure by inhalation or intratracheal instillation (ITI) to different particles with varying inherent pulmonary toxicities in both rat and mouse models. General findings indicate that total BAL cell counts using the automated and manual methods tended to agree after inhalation or ITI exposure to particle samples that are relatively nontoxic or at later time points after exposure to a pneumotoxic particle when the response resolves. However, when the initial lung inflammation and cytotoxicity was high after exposure to a pneumotoxic particle, significant differences were observed when comparing cell counts from the automated, flow cytometry and manual methods. When using total BAL cell count for differential calculations from the automated method, depending on the cell diameter size range cutoff, the data suggest that the number of lung polymorphonuclear leukocytes (PMN) varies. Importantly, the automated counts, regardless of the size cutoff, still indicated a greater number of total lung PMN when compared with the manual method, which agreed more closely with flow cytometry. The results suggest that either the manual method or flow cytometry would be better suited for BAL studies where cytotoxicity is an unknown variable. PMID:27251196
Milne, Marjorie E; Steward, Christopher; Firestone, Simon M; Long, Sam N; O'Brien, Terrence J; Moffat, Bradford A
2016-04-01
To develop representative MRI atlases of the canine brain and to evaluate 3 methods of atlas-based segmentation (ABS). 62 dogs without clinical signs of epilepsy and without MRI evidence of structural brain disease. The MRI scans from 44 dogs were used to develop 4 templates on the basis of brain shape (brachycephalic, mesaticephalic, dolichocephalic, and combined mesaticephalic and dolichocephalic). Atlas labels were generated by segmenting the brain, ventricular system, hippocampal formation, and caudate nuclei. The MRI scans from the remaining 18 dogs were used to evaluate 3 methods of ABS (manual brain extraction and application of a brain shape-specific template [A], automatic brain extraction and application of a brain shape-specific template [B], and manual brain extraction and application of a combined template [C]). The performance of each ABS method was compared by calculation of the Dice and Jaccard coefficients, with manual segmentation used as the gold standard. Method A had the highest mean Jaccard coefficient and was the most accurate ABS method assessed. Measures of overlap for ABS methods that used manual brain extraction (A and C) ranged from 0.75 to 0.95 and compared favorably with repeated measures of overlap for manual extraction, which ranged from 0.88 to 0.97. Atlas-based segmentation was an accurate and repeatable method for segmentation of canine brain structures. It could be performed more rapidly than manual segmentation, which should allow the application of computer-assisted volumetry to large data sets and clinical cases and facilitate neuroimaging research and disease diagnosis.
Zeidler-Erdely, Patti C; Antonini, James M; Meighan, Terence G; Young, Shih-Houng; Eye, Tracy J; Hammer, Mary Ann; Erdely, Aaron
2016-08-01
Pulmonary toxicity studies often use bronchoalveolar lavage (BAL) to investigate potential adverse lung responses to a particulate exposure. The BAL cellular fraction is counted, using automated (i.e. Coulter Counter®), flow cytometry or manual (i.e. hemocytometer) methods, to determine inflammatory cell influx. The goal of the study was to compare the different counting methods to determine which is optimal for examining BAL cell influx after exposure by inhalation or intratracheal instillation (ITI) to different particles with varying inherent pulmonary toxicities in both rat and mouse models. General findings indicate that total BAL cell counts using the automated and manual methods tended to agree after inhalation or ITI exposure to particle samples that are relatively nontoxic or at later time points after exposure to a pneumotoxic particle when the response resolves. However, when the initial lung inflammation and cytotoxicity was high after exposure to a pneumotoxic particle, significant differences were observed when comparing cell counts from the automated, flow cytometry and manual methods. When using total BAL cell count for differential calculations from the automated method, depending on the cell diameter size range cutoff, the data suggest that the number of lung polymorphonuclear leukocytes (PMN) varies. Importantly, the automated counts, regardless of the size cutoff, still indicated a greater number of total lung PMN when compared with the manual method, which agreed more closely with flow cytometry. The results suggest that either the manual method or flow cytometry would be better suited for BAL studies where cytotoxicity is an unknown variable.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Huang, Zhenyu; Du, Pengwei; Kosterev, Dmitry
2013-05-01
Disturbance data recorded by phasor measurement units (PMU) offers opportunities to improve the integrity of dynamic models. However, manually tuning parameters through play-back events demands significant efforts and engineering experiences. In this paper, a calibration method using the extended Kalman filter (EKF) technique is proposed. The formulation of EKF with parameter calibration is discussed. Case studies are presented to demonstrate its validity. The proposed calibration method is cost-effective, complementary to traditional equipment testing for improving dynamic model quality.
Flexible Reporting of Clinical Data
Andrews, Robert D.
1987-01-01
Two prototype methods have been developed to aid in the presentation of relevant clinical data: 1) an integrated report that displays results from a patient's computer-stored data and also allows manual entry of data, and 2) a graph program that plots results of multiple kinds of tests. These reports provide a flexible means of displaying data to help evaluate patient treatment. The two methods also explore ways of integrating the display of data from multiple components of the Veterans Administration's (VA) Decentralized Hospital Computer Program (DHCP) database.
Locating articular cartilage in MR images
NASA Astrophysics Data System (ADS)
Folkesson, Jenny; Dam, Erik; Pettersen, Paola; Olsen, Ole F.; Nielsen, Mads; Christiansen, Claus
2005-04-01
Accurate computation of the thickness of the articular cartilage is of great importance when diagnosing and monitoring the progress of joint diseases such as osteoarthritis. A fully automated cartilage assessment method is preferable compared to methods using manual interaction in order to avoid inter- and intra-observer variability. As a first step in the cartilage assessment, we present an automatic method for locating articular cartilage in knee MRI using supervised learning. The next step will be to fit a variable shape model to the cartilage, initiated at the location found using the method presented in this paper. From the model, disease markers will be extracted for the quantitative evaluation of the cartilage. The cartilage is located using an ANN-classifier, where every voxel is classified as cartilage or non-cartilage based on prior knowledge of the cartilage structure. The classifier is tested using leave-one-out-evaluation, and we found the average sensitivity and specificity to be 91.0% and 99.4%, respectively. The center of mass calculated from voxels classified as cartilage are similar to the corresponding values calculated from manual segmentations, which confirms that this method can find a good initial position for a shape model.
A tool for design of primers for microRNA-specific quantitative RT-qPCR.
Busk, Peter K
2014-01-28
MicroRNAs are small but biologically important RNA molecules. Although different methods can be used for quantification of microRNAs, quantitative PCR is regarded as the reference that is used to validate other methods. Several commercial qPCR assays are available but they often come at a high price and the sequences of the primers are not disclosed. An alternative to commercial assays is to manually design primers but this work is tedious and, hence, not practical for the design of primers for a larger number of targets. I have developed the software miRprimer for automatic design of primers for the method miR-specific RT-qPCR, which is one of the best performing microRNA qPCR methods available. The algorithm is based on an implementation of the previously published rules for manual design of miR-specific primers with the additional feature of evaluating the propensity of formation of secondary structures and primer dimers. Testing of the primers showed that 76 out of 79 primers (96%) worked for quantification of microRNAs by miR-specific RT-qPCR of mammalian RNA samples. This success rate corresponds to the success rate of manual primer design. Furthermore, primers designed by this method have been distributed to several labs and used successfully in published studies. The software miRprimer is an automatic and easy method for design of functional primers for miR-specific RT-qPCR. The application is available as stand-alone software that will work on the MS Windows platform and in a developer version written in the Ruby programming language.
Shahidi, Shoaleh; Bahrampour, Ehsan; Soltanimehr, Elham; Zamani, Ali; Oshagh, Morteza; Moattari, Marzieh; Mehdizadeh, Alireza
2014-09-16
Two-dimensional projection radiographs have been traditionally considered the modality of choice for cephalometric analysis. To overcome the shortcomings of two-dimensional images, three-dimensional computed tomography (CT) has been used to evaluate craniofacial structures. However, manual landmark detection depends on medical expertise, and the process is time-consuming. The present study was designed to produce software capable of automated localization of craniofacial landmarks on cone beam (CB) CT images based on image registration and to evaluate its accuracy. The software was designed using MATLAB programming language. The technique was a combination of feature-based (principal axes registration) and voxel similarity-based methods for image registration. A total of 8 CBCT images were selected as our reference images for creating a head atlas. Then, 20 CBCT images were randomly selected as the test images for evaluating the method. Three experts twice located 14 landmarks in all 28 CBCT images during two examinations set 6 weeks apart. The differences in the distances of coordinates of each landmark on each image between manual and automated detection methods were calculated and reported as mean errors. The combined intraclass correlation coefficient for intraobserver reliability was 0.89 and for interobserver reliability 0.87 (95% confidence interval, 0.82 to 0.93). The mean errors of all 14 landmarks were <4 mm. Additionally, 63.57% of landmarks had a mean error of <3 mm compared with manual detection (gold standard method). The accuracy of our approach for automated localization of craniofacial landmarks, which was based on combining feature-based and voxel similarity-based methods for image registration, was acceptable. Nevertheless we recommend repetition of this study using other techniques, such as intensity-based methods.
Thomas, Marianna S; Newman, David; Leinhard, Olof Dahlqvist; Kasmai, Bahman; Greenwood, Richard; Malcolm, Paul N; Karlsson, Anette; Rosander, Johannes; Borga, Magnus; Toms, Andoni P
2014-09-01
To measure the test-retest reproducibility of an automated system for quantifying whole body and compartmental muscle volumes using wide bore 3 T MRI. Thirty volunteers stratified by body mass index underwent whole body 3 T MRI, two-point Dixon sequences, on two separate occasions. Water-fat separation was performed, with automated segmentation of whole body, torso, upper and lower leg volumes, and manually segmented lower leg muscle volumes. Mean automated total body muscle volume was 19·32 L (SD9·1) and 19·28 L (SD9·12) for first and second acquisitions (Intraclass correlation coefficient (ICC) = 1·0, 95% level of agreement -0·32-0·2 L). ICC for all automated test-retest muscle volumes were almost perfect (0·99-1·0) with 95% levels of agreement 1.8-6.6% of mean volume. Automated muscle volume measurements correlate closely with manual quantification (right lower leg: manual 1·68 L (2SD0·6) compared to automated 1·64 L (2SD 0·6), left lower leg: manual 1·69 L (2SD 0·64) compared to automated 1·63 L (SD0·61), correlation coefficients for automated and manual segmentation were 0·94-0·96). Fully automated whole body and compartmental muscle volume quantification can be achieved rapidly on a 3 T wide bore system with very low margins of error, excellent test-retest reliability and excellent correlation to manual segmentation in the lower leg. Sarcopaenia is an important reversible complication of a number of diseases. Manual quantification of muscle volume is time-consuming and expensive. Muscles can be imaged using in and out of phase MRI. Automated atlas-based segmentation can identify muscle groups. Automated muscle volume segmentation is reproducible and can replace manual measurements.
Training children aged 5-10 years in manual compliance control to improve drawing and handwriting.
Bingham, Geoffrey P; Snapp-Childs, Winona
2018-04-12
A large proportion of school-aged children exhibit poor drawing and handwriting. This prevalence limits the availability of therapy. We developed an automated method for training improved manual compliance control and relatedly, prospective control of a stylus. The approach included a difficult training task, while providing parametrically modifiable support that enables the children to perform successfully while developing good compliance control. The task was to use a stylus to push a bead along a 3D wire path. Support was provided by making the wire magnetically attractive to the stylus. Support was progressively reduced as 3D tracing performance improved. We report studies that (1) compared performance of Typically Developing (TD) children and children with Developmental Coordination Disorder (DCD), (2) tested training with active versus passive movement, (3) tested progressively reduced versus constant or no support during training, (4) tested children of different ages, (5) tested the transfer of training to a drawing task, (6) tested the specificity of training in respect to the size, shape and dimensionality of figures, and (7) investigated the relevance of the training task to the Beery VMI, an inventory used to diagnose DCD. The findings were as follows. (1) Pre-training performance of TD and DCD children was the same and good with high support but distinct and poor with low support. Support yielded good self-efficacy that motivated training. Post training performance with no support was improved and the same for TD and DCD children. (2) Actively controlled movements were required for improved performance. (3) Progressively reduced support was required for good performance during and after training. (4) Age differences in performance during pre-training were eliminated post-training. (5) Improvements transferred to drawing. (6) There was no evidence of specificity of training in transfer. (7) Disparate Beery scores were reflected in pre-training but not post-training performance. We conclude that the method improves manual compliance control, and more generally, prospective control of movements used in drawing performance. Copyright © 2018. Published by Elsevier B.V.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Burgmans, Mark Christiaan, E-mail: m.c.burgmans@lumc.nl; Harder, J. Michiel den, E-mail: chiel.den.harder@gmail.com; Meershoek, Philippa, E-mail: P.Meershoek@lumc.nl
PurposeTo determine the accuracy of automatic and manual co-registration methods for image fusion of three-dimensional computed tomography (CT) with real-time ultrasonography (US) for image-guided liver interventions.Materials and MethodsCT images of a skills phantom with liver lesions were acquired and co-registered to US using GE Logiq E9 navigation software. Manual co-registration was compared to automatic and semiautomatic co-registration using an active tracker. Also, manual point registration was compared to plane registration with and without an additional translation point. Finally, comparison was made between manual and automatic selection of reference points. In each experiment, accuracy of the co-registration method was determined bymore » measurement of the residual displacement in phantom lesions by two independent observers.ResultsMean displacements for a superficial and deep liver lesion were comparable after manual and semiautomatic co-registration: 2.4 and 2.0 mm versus 2.0 and 2.5 mm, respectively. Both methods were significantly better than automatic co-registration: 5.9 and 5.2 mm residual displacement (p < 0.001; p < 0.01). The accuracy of manual point registration was higher than that of plane registration, the latter being heavily dependent on accurate matching of axial CT and US images by the operator. Automatic reference point selection resulted in significantly lower registration accuracy compared to manual point selection despite lower root-mean-square deviation (RMSD) values.ConclusionThe accuracy of manual and semiautomatic co-registration is better than that of automatic co-registration. For manual co-registration using a plane, choosing the correct plane orientation is an essential first step in the registration process. Automatic reference point selection based on RMSD values is error-prone.« less
Predicting the clinical performance of dental students with a manual dexterity test
Lugassy, Diva; Levanon, Yafi; Pilo, Raphael; Shelly, Asaf; Rosen, Gal; Meirowitz, Avi
2018-01-01
Dentists must be skilled when using dental mirrors. Working with mirrors requires spatial perception, bimanual coordination, perceptual learning and fine motor skills. Many studies have attempted to determine the predictors of manual skills among pre-clinical students, but consensus has yet to be reached. We hypothesized that valid and reliable occupational therapy test performance regarding indirect vision would differ between dental students and junior dentists and would explain the variance in manual skill performance in pre-clinical courses. To test this hypothesis, we applied the Purdue Pegboard test and O’Connor Tweezer Dexterity test under different conditions of direct and indirect vision. We administered these tests to students in phantom-head academic courses in 2015 and 2016 and to junior dentists. Students performed the tests at three time points: before phantom training (T0), at the end of the training (T1) and in the middle of the following year of study (T2). Dentists performed the same tests twice at 1st and 2nd trials one week apart. The results showed that indirect tasks were significantly more difficult to perform for both groups. These dexterity tests were sensitive enough to detect students’ improvement after phantom training. The dentists’ performances were significantly better than those of students at T0, specifically with regard to the use of tweezers under direct and indirect vision (the O’Connor test). A regression analysis showed that students’ manual grades obtained at the beginning of the phantom course, their performance on the Purdue test using both hands, and their performance on the O’Connor test under indirect vision predicted phantom course success in 80% of cases. The O’Connor test under indirect vision is the most informative means of monitoring and predicting the manual skills required in the pre-clinical year of dentistry studies. PMID:29518127
Application of drilling, coring, and sampling techniques to test holes and wells
Shuter, Eugene; Teasdale, Warren E.
1989-01-01
The purpose of this manual is to provide ground-water hydrologists with a working knowledge of the techniques of test drilling, auger drilling, coring and sampling, and the related drilling and sampling equipment. For the most part, the techniques discussed deal with drilling, sampling, and completion of test holes in unconsolidated sediments because a hydrologist is interested primarily in shallow-aquifer data in this type of lithology. Successful drilling and coring of these materials usually is difficult, and published research information on the subject is not readily available. The authors emphasize in-situ sampling of unconsolidated sediments to obtain virtually undisturbed samples. Particular attention is given to auger drilling and hydraulic-rotary methods of drilling because these are the principal means of test drilling performed by the U.S. Geological Survey during hydrologic studies. Techniques for sampling areas contaminated by solid or liquid waste are discussed. Basic concepts of well development and a detailed discussion of drilling muds, as related to hole conditioning, also are included in the report. The information contained in this manual is intended to help ground-water hydrologists obtain useful subsurface data and samples from their drilling programs.
Tabard-Fougère, Anne; Rose-Dulcina, Kevin; Pittet, Vincent; Dayer, Romain; Vuillerme, Nicolas; Armand, Stéphane
2018-02-01
Electromyography (EMG) is an important parameter in Clinical Gait Analysis (CGA), and is generally interpreted with timing of activation. EMG amplitude comparisons between individuals, muscles or days need normalization. There is no consensus on existing methods. The gold standard, maximum voluntary isometric contraction (MVIC), is not adapted to pathological populations because patients are often unable to perform an MVIC. The normalization method inspired by the isometric grade 3 of manual muscle testing (isoMMT3), which is the ability of a muscle to maintain a position against gravity, could be an interesting alternative. The aim of this study was to evaluate the within- and between-day reliability of the isoMMT3 EMG normalizing method during gait compared with the conventional MVIC method. Lower limb muscles EMG (gluteus medius, rectus femoris, tibialis anterior, semitendinosus) were recorded bilaterally in nine healthy participants (five males, aged 29.7±6.2years, BMI 22.7±3.3kgm -2 ) giving a total of 18 independent legs. Three repeated measurements of the isoMMT3 and MVIC exercises were performed with an EMG recording. EMG amplitude of the muscles during gait was normalized by these two methods. This protocol was repeated one week later. Within- and between-day reliability of normalization tasks were similar for isoMMT3 and MVIC methods. Within- and between-day reliability of gait EMG normalized by isoMMT3 was higher than with MVIC normalization. These results indicate that EMG normalization using isoMMT3 is a reliable method with no special equipment needed and will support CGA interpretation. The next step will be to evaluate this method in pathological populations. Copyright © 2017 Elsevier B.V. All rights reserved.
Operation and maintenance manual for a preprototype Sabatier carbon dioxide reduction subsystem
NASA Technical Reports Server (NTRS)
Kleiner, G. N.
1981-01-01
The manual delineates the procedures, precautions and necessary sequences of steps required to prepare the package for test, provide troubleshooting information and perform required maintenance by the operating crew. The manual is divided into five sections: Installation, Checkout, Operation, Failure Detection/Isolation and Maintenance.
ERIC Educational Resources Information Center
Luborsky, Lester; And Others
1982-01-01
Tested whether independent judges could recognize three different manual-guided psychotherapies, drug counseling, supportive-expressive psychotherapy, and cognitive-behavioral using a special rating form containing scales for the characteristic aspects of each type. Results indicated that manual-guided therapies can be reliably recognized.…
SRM Manual, Selected Resource Materials: Description and Evaluation.
ERIC Educational Resources Information Center
Alberta Dept. of Education, Edmonton. Special Educational Services Branch.
Provided in the manual is descriptive and evaluative information on 67 instructional materials or programs frequently used with exceptional children in Alberta schools. A flow chart describes the three methods of using the manual: l) to obtain descriptive and evaluative information of an instruction program in the manual 2) to classify and record…
A Manual Segmentation Tool for Three-Dimensional Neuron Datasets.
Magliaro, Chiara; Callara, Alejandro L; Vanello, Nicola; Ahluwalia, Arti
2017-01-01
To date, automated or semi-automated software and algorithms for segmentation of neurons from three-dimensional imaging datasets have had limited success. The gold standard for neural segmentation is considered to be the manual isolation performed by an expert. To facilitate the manual isolation of complex objects from image stacks, such as neurons in their native arrangement within the brain, a new Manual Segmentation Tool (ManSegTool) has been developed. ManSegTool allows user to load an image stack, scroll down the images and to manually draw the structures of interest stack-by-stack. Users can eliminate unwanted regions or split structures (i.e., branches from different neurons that are too close each other, but, to the experienced eye, clearly belong to a unique cell), to view the object in 3D and save the results obtained. The tool can be used for testing the performance of a single-neuron segmentation algorithm or to extract complex objects, where the available automated methods still fail. Here we describe the software's main features and then show an example of how ManSegTool can be used to segment neuron images acquired using a confocal microscope. In particular, expert neuroscientists were asked to segment different neurons from which morphometric variables were subsequently extracted as a benchmark for precision. In addition, a literature-defined index for evaluating the goodness of segmentation was used as a benchmark for accuracy. Neocortical layer axons from a DIADEM challenge dataset were also segmented with ManSegTool and compared with the manual "gold-standard" generated for the competition.
Near-station terrain corrections for gravity data by a surface-integral technique
Gettings, M.E.
1982-01-01
A new method of computing gravity terrain corrections by use of a digitizer and digital computer can result in substantial savings in the time and manual labor required to perform such corrections by conventional manual ring-chart techniques. The method is typically applied to estimate terrain effects for topography near the station, for example within 3 km of the station, although it has been used successfully to a radius of 15 km to estimate corrections in areas where topographic mapping is poor. Points (about 20) that define topographic maxima, minima, and changes in the slope gradient are picked on the topographic map, within the desired radius of correction about the station. Particular attention must be paid to the area immediately surrounding the station to ensure a good topographic representation. The horizontal and vertical coordinates of these points are entered into the computer, usually by means of a digitizer. The computer then fits a multiquadric surface to the input points to form an analytic representation of the surface. By means of the divergence theorem, the gravity effect of an interior closed solid can be expressed as a surface integral, and the terrain correction is calculated by numerical evaluation of the integral over the surfaces of a cylinder, The vertical sides of which are at the correction radius about the station, the flat bottom surface at the topographic minimum, and the upper surface given by the multiquadric equation. The method has been tested with favorable results against models for which an exact result is available and against manually computed field-station locations in areas of rugged topography. By increasing the number of points defining the topographic surface, any desired degree of accuracy can be obtained. The method is more objective than manual ring-chart techniques because no average compartment elevations need be estimated ?
Otani, Kyoko; Nakazono, Akemi; Salgo, Ivan S; Lang, Roberto M; Takeuchi, Masaaki
2016-10-01
Echocardiographic determination of left heart chamber volumetric parameters by using manual tracings during multiple beats is tedious in atrial fibrillation (AF). The aim of this study was to determine the usefulness of fully automated left chamber quantification software with single-beat three-dimensional transthoracic echocardiographic data sets in patients with AF. Single-beat full-volume three-dimensional transthoracic echocardiographic data sets were prospectively acquired during consecutive multiple cardiac beats (≥10 beats) in 88 patients with AF. In protocol 1, left ventricular volumes, left ventricular ejection fraction, and maximal left atrial volume were validated using automated quantification against the manual tracing method in identical beats in 10 patients. In protocol 2, automated quantification-derived averaged values from multiple beats were compared with the corresponding values obtained from the indexed beat in all patients. Excellent correlations of left chamber parameters between automated quantification and the manual method were observed (r = 0.88-0.98) in protocol 1. The time required for the analysis with the automated quantification method (5 min) was significantly less compared with the manual method (27 min) (P < .0001). In protocol 2, there were excellent linear correlations between the averaged left chamber parameters and the corresponding values obtained from the indexed beat (r = 0.94-0.99), and test-retest variability of left chamber parameters was low (3.5%-4.8%). Three-dimensional transthoracic echocardiography with fully automated quantification software is a rapid and reliable way to measure averaged values of left heart chamber parameters during multiple consecutive beats. Thus, it is a potential new approach for left chamber quantification in patients with AF in daily routine practice. Copyright © 2016 American Society of Echocardiography. Published by Elsevier Inc. All rights reserved.
78 FR 41285 - Airworthiness Directives; Pilatus Aircraft Ltd. Airplanes
Federal Register 2010, 2011, 2012, 2013, 2014
2013-07-10
... manual). The limitations were revised to include an emergency fuel control system adjustment test. We are... a 300 Flight Hour (FH) hour inspection on the Emergency Fuel Control System (FCS). For the reason...., maintenance manual). The limitations were revised to include an emergency fuel control system adjustment test...
Maine Educational Assessment (MEA) Operational Procedures, March 2005 Administration.
ERIC Educational Resources Information Center
Maine Department of Education, 2004
2004-01-01
This document is intended for use in conjunction with "Policies and Procedures for Accommodations and Alternate Assessment to the MEA," and both the "MEA Principal/Test Coordinator's Manual" and the "MEA Test Administrator's Manual." The first section, Enrollment, covers the following subjects: (1) Participation of Enrolled Students; (2) Students…
40 CFR Appendix I to Subparts D... - Motorcycle Noise Emission Test Procedures
Code of Federal Regulations, 2012 CFR
2012-07-01
... 40 Protection of Environment 26 2012-07-01 2011-07-01 true Motorcycle Noise Emission Test... valid measurements. Operating manuals or other literature furnished by the instrument manufacturer must... instrumentation is essential to obtain valid measurements. Operating manuals or other literature furnished by the...
Federal Register 2010, 2011, 2012, 2013, 2014
2011-09-16
...; Comment Request; Election Assistance Commission's Voting System Test Laboratory Program Manual, Version 1... Paperwork Reduction Act of 1995, the U.S. Election Assistance Commission (EAC) invites the general public... information collection, EAC's Voting System Test Laboratory Program Manual, Version 1.0. Comments are invited...
Vocational Education Safety Instruction Manual.
ERIC Educational Resources Information Center
Cropley, Russell, Ed.; Doherty, Susan Sloan, Ed.
This manual describes four program areas in vocational education safety instruction: (1) introduction to a safety program; (2) resources to ensure laboratory safety; (3) safety program implementation; and (4) safety rules and safety tests. The safety rules and tests included in section four are for the most common tools and machines used in…
Araújo, Marcelo Marotta; Lauria, Andrezza; Mendes, Marcelo Breno Meneses; Claro, Ana Paula Rosifini Alves; Claro, Cristiane Aparecida de Assis; Moreira, Roger William Fernandes
2015-12-01
The aim of this study was to analyze, through Vickers hardness test and photoelasticity analysis, pre-bent areas, manually bent areas, and areas without bends of 10-mm advancement pre-bent titanium plates (Leibinger system). The work was divided into three groups: group I-region without bend, group II-region of 90° manual bend, and group III-region of 90° pre-fabricated bends. All the materials were evaluated through hardness analysis by the Vickers hardness test, stress analysis by residual images obtained in a polariscope, and photoelastic analysis by reflection during the manual bending. The data obtained from the hardness tests were statistically analyzed using ANOVA and Tukey's tests at a significance level of 5 %. The pre-bent plate (group III) showed hardness means statistically significantly higher (P < 0.05) than those of the other groups (I-region without bends, II-90° manually bent region). Through the study of photoelastic reflection, it was possible to identify that the stress gradually increased, reaching a pink color (1.81 δ / λ), as the bending was performed. A general analysis of the results showed that the bent plate region of pre-bent titanium presented the best results.
[Manual therapy in general practice].
Березуцкий, Владимир И
2016-01-01
The article is devoted to manual therapy practice for diagnostics and treatment of vertebrogenic pain syndrome in general practice. Analytical roundup of sources proves medical advantage of implementation of manual therapy basic methods by general practice specialists.
Computerized in vitro test for chemical toxicity based on tetrahymena swimming patterns
NASA Technical Reports Server (NTRS)
Noever, David A.; Matsos, Helen C.; Cronise, Raymond J.; Looger, Loren L.; Relwani, Rachna A.; Johnson, Jacqueline U.
1994-01-01
An apparatus and method for rapidly determining chemical toxicity was evaluated. The toxicity monitor includes an automated scoring of how motile biological cells (Tetrahymena pyriformis) slow down or otherwise change their swimming patterns in a hostile chemical environment. The device, called the Motility Assay Apparatus (MAA) is tested for 30 second determination of chemical toxicity in 20 aqueous samples containing trace organics and salts. With equal or better detection limits, results compare favorably to in vivo animal tests of eye irritancy, in addition to agreeing for all chemicals with previous manual evaluations of single cell motility.
Uitdehaag, K A; Rodenburg, T B; van Hierden, Y M; Bolhuis, J E; Toscano, M J; Nicol, C J; Komen, J
2008-09-01
Birds from Rhode Island Red (RIR) origin show a lower fear response and less feather pecking than birds from White Leghorn (WL) origin. This study investigated whether responses in fear eliciting tests were affected if RIR and WL birds were housed together. Experimental groups contained either birds from one line only ('pure' groups) or an equal number of RIR and WL birds ('mixed' groups). These arrangements were maintained from hatch onwards, throughout the rearing and laying period. Birds were subjected to open field tests at 5-6 weeks and 17-18 weeks of age and to manual restraint tests at 7-8 weeks and 24 weeks of age. RIR birds were more active in both open field tests and in the manual restraint test at 24 weeks of age as compared with WL birds. RIR birds from pure groups were more active in the open field test at 17-18 weeks and in the manual restraint test at 24 weeks of age than RIR birds from mixed groups. These results suggest that otherwise low fearful RIR birds may adopt a higher fear response if they are housed together with more fearful conspecifics. These effects do not emerge until after 8 weeks of age.
Gagnon, Dany H; Roy, Audrey; Verrier, Molly C; Duclos, Cyril; Craven, B Cathy; Nadeau, Sylvie
2016-07-01
To quantify and compare the responsiveness and concurrent validity of 3 performance-based manual wheelchair propulsion tests among manual wheelchair users with subacute spinal cord injury (SCI) undergoing inpatient rehabilitation. Quasi-experimental repeated-measures design. Publicly funded comprehensive inpatient SCI rehabilitation program. Consenting adult manual wheelchair users with a subacute SCI admitted and discharged from inpatient rehabilitation (N=14). Participants performed 20-m propulsion at both self-selected natural and maximal speeds, the slalom, and the 6-minute propulsion tests at rehabilitation admission and discharge. Time required to complete the performance-based wheelchair propulsion tests. Standardized response means (SRMs) were computed for each performance test and Pearson correlation coefficients (r) were calculated to explore the associations between performance tests. The slalom (SRM=1.24), 20-m propulsion at maximum speed (SRM=.99), and 6-minute propulsion tests (SRM=.84) were the most responsive. The slalom and 20-m propulsion at maximum speed were strongly correlated at both admission (r=.93) and discharge (r=.92). The slalom and 6-minute propulsion tests best document wheelchair propulsion performance change over the course of inpatient rehabilitation. Adding the 20-m propulsion test performed at maximal speed provides a complementary description of performance change. Copyright © 2016 American Congress of Rehabilitation Medicine. Published by Elsevier Inc. All rights reserved.
Medical Device for Automated Prick Test Reading.
Justo, Xabier; Diaz, Inaki; Gil, Jorge Juan; Gastaminza, Gabriel
2018-05-01
Allergy tests are routinely performed in most hospitals everyday. However, measuring the outcomes of these tests is still a very laborious manual task. Current methods and systems lack of precision and repeatability. This paper presents a novel mechatronic system that is able to scan a patient's entire arm and provide allergists with precise measures of wheals for diagnosis. The device is based on 3-D laser technology and specific algorithms have been developed to process the information gathered. This system aims to automate the reading of skin prick tests and make gains in speed, accuracy, and reliability. Several experiments have been performed to evaluate the performance of the system.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Roberts, Nathan V.
2016-09-28
Camellia began as an effort to simplify implementation of efficient solvers for the discontinuous Petrov-Galerkin (DPG) finite element methodology of Demkowicz and Gopalakrishnan. Since then, the feature set has expanded, to allow implementation of traditional continuous Galerkin methods, as well as discontinuous Galerkin (DG) methods, hybridizable DG (HDG) methods, first-order-system least squares (FOSLS), and the primal DPG method. This manual serves as an introduction to using Camellia. We begin, in Section 1.1, by describing some of the core features of Camellia. In Section 1.2 we provide an outline of the manual as a whole.
Ghasemi, Negin; Janani, Maryam; Razi, Tahmineh; Atharmoghaddam, Faezeh
2017-03-01
It is necessary apical plug material to exhibit proper adaptation with the root canal walls. Presence of voids at the interface between the root canal wall and this material result in micro leakage, which might have a relationship with post treatment disease. The aim of the present study was to evaluate the effect of different mixing (manual and ultrasonic) and placement (manual and manual in association with indirect ultrasonic) method of Mineral Trioxide Aggregate (MTA) on the void count and dimension in the apical plug in natural teeth with simulated open apices. Eighty human maxillary central incisors were selected. After simulation of the open apex model, the teeth were assigned to 4 groups based on the mixing and placement techniques of MTA: group 1, manual mixing and manual placement; group 2, manual mixing and manual placement in association with indirect ultrasonic; group 3, ultrasonic mixing and and manual placement; and group 4, ultrasonic mixing and manual placement in association with indirect ultrasonic. The prepared samples were placed within gypsum sockets in which the periodontal ligament was reconstructed with polyether impression material. In group 1, after mixing, the material was condensed with a hand plugger. In group 2, after mixing, the ultrasonic tip was contacted with the hand plugger for 2 seconds. In groups 3 and 4, mixing was carried out with the ultrasonic tip for 5 seconds and in groups 3 and 4, similar to groups 1 and 2, respectively, the materials were placed as apical plugs, measuring 3 mm in length. A wet cotton pellet was placed at canal orifices and dressed with Cavit. After one week, the cone beam computed tomography (CBCT) technique was used to count the number of voids between the material and root canal walls. The void dimensions were determined using the following scoring system: score 1, absence of voids; score 2, the void size less than half of the dimensions of the evaluated cross-section; score 3, the void size larger than half of the dimensions of the evaluated cross-section. Chi-squared and Fisher's exact tests were used for statistical analyses. Statistical significance was set at P <0.05. The maximum (13) and minimum (3) number of voids were detected in groups 2 and 3, respectively. There were no significant differences between groups 1 and 3 in the number of voids ( p >0.05). Evaluation of void dimensions showed no score 3 in any of the study groups and the dimensions of all the voids conformed to score 2. Under the limitations of the present study, use of ultrasonic mixing and manual placement techniques resulted in a decrease in the number of voids in the apical plug. Key words: Apical plug, MTA, ultrasonic, void.
Dental health knowledge in a group of Latin American refugees in Sweden.
Groisman, M; Bratthall, G T; Harari, S G; Tapia, J A
1989-01-01
Sixty-nine Latin American refugees with a mean age of 31 years participated in this study. The knowledge about dental health before and after reading a self-instructional manual in Spanish was tested by questionnaires. The test persons were also interviewed about their dietary habits. The results showed an improvement of 30% of right answers after reading the manual and that a frequent sugar consumption was common. This indicates that a self-instructional manual can be of value in oral health prevention in a similar group of non-resident immigrants.
Analytical methods manual for the Mineral Resource Surveys Program, U.S. Geological Survey
Arbogast, Belinda F.
1996-01-01
The analytical methods validated by the Mineral Resource Surveys Program, Geologic Division, is the subject of this manual. This edition replaces the methods portion of Open-File Report 90-668 published in 1990. Newer methods may be used which have been approved by the quality assurance (QA) project and are on file with the QA coordinator.This manual is intended primarily for use by laboratory scientists; this manual can also assist laboratory users to evaluate the data they receive. The analytical methods are written in a step by step approach so that they may be used as a training tool and provide detailed documentation of the procedures for quality assurance. A "Catalog of Services" is available for customer (submitter) use with brief listings of:the element(s)/species determined,method of determination,reference to cite,contact person,summary of the technique,and analyte concentration range.For a copy please contact the Branch office at (303) 236-1800 or fax (303) 236-3200.
Mixed methods research - the best of both worlds?
van Griensven, Hubert; Moore, Ann P; Hall, Valerie
2014-10-01
There has been a bias towards quantitative research approaches within manual therapy, which may have resulted in a narrow understanding of manual therapy practice. The aim of this Masterclass is to make a contribution to the expansion of methodologies used in manual therapy enquiry by discussing mixed methods research (MMR), a methodology which utilises both qualitative and quantitative methods within a single study in order to provide more comprehensive insights. To review rationales for MMR, as well as some of the common design options and potential difficulties. The paper also discusses theoretical frameworks that have been used to underpin qualitative and quantitative research, and ongoing debates about the possibility of combining them. Complexities associated with health and manual therapy cannot always be investigated satisfactorily by using a single research method. Some issues require a more comprehensive understanding, which may be provided by combining the strengths of quantitative and qualitative methods in a mixed methods study. Copyright © 2014 Elsevier Ltd. All rights reserved.
Burgmans, Mark Christiaan; den Harder, J Michiel; Meershoek, Philippa; van den Berg, Nynke S; Chan, Shaun Xavier Ju Min; van Leeuwen, Fijs W B; van Erkel, Arian R
2017-06-01
To determine the accuracy of automatic and manual co-registration methods for image fusion of three-dimensional computed tomography (CT) with real-time ultrasonography (US) for image-guided liver interventions. CT images of a skills phantom with liver lesions were acquired and co-registered to US using GE Logiq E9 navigation software. Manual co-registration was compared to automatic and semiautomatic co-registration using an active tracker. Also, manual point registration was compared to plane registration with and without an additional translation point. Finally, comparison was made between manual and automatic selection of reference points. In each experiment, accuracy of the co-registration method was determined by measurement of the residual displacement in phantom lesions by two independent observers. Mean displacements for a superficial and deep liver lesion were comparable after manual and semiautomatic co-registration: 2.4 and 2.0 mm versus 2.0 and 2.5 mm, respectively. Both methods were significantly better than automatic co-registration: 5.9 and 5.2 mm residual displacement (p < 0.001; p < 0.01). The accuracy of manual point registration was higher than that of plane registration, the latter being heavily dependent on accurate matching of axial CT and US images by the operator. Automatic reference point selection resulted in significantly lower registration accuracy compared to manual point selection despite lower root-mean-square deviation (RMSD) values. The accuracy of manual and semiautomatic co-registration is better than that of automatic co-registration. For manual co-registration using a plane, choosing the correct plane orientation is an essential first step in the registration process. Automatic reference point selection based on RMSD values is error-prone.
An Improved Manual Method for NOx Emission Measurement.
ERIC Educational Resources Information Center
Dee, L. A.; And Others
The current manual NO (x) sampling and analysis method was evaluated. Improved time-integrated sampling and rapid analysis methods were developed. In the new method, the sample gas is drawn through a heated bed of uniquely active, crystalline, Pb02 where NO (x) is quantitatively absorbed. Nitrate ion is later extracted with water and the…
Alford, Timothy J; Roberts, W Eugene; Hartsfield, James K; Eckert, George J; Snyder, Ronald J
2011-05-01
Utilize American Board of Orthodontics (ABO) cast/radiographic evaluation (CRE) to compare a series of 63 consecutive patients, finished with manual wire bending (conventional) treatment, vs a subsequent series of 69 consecutive patients, finished by the same orthodontist using the SureSmile™ (SS) method. Records of 132 nonextraction patients were scored by a calibrated examiner blinded to treatment mode. Age and discrepancy index (DI) between groups were compared by t-tests. A chi-square test was used to compare for differences in sex and whether the patient was treated using braces only (no orthopedic correction). Analysis of covariance tested for differences in CRE outcomes and treatment times, with sex and DI included as covariates. A logarithmic transformation of CRE outcomes and treatment times was used because their distributions were skewed. Significance was defined as P < .05. Compared with conventional finishing, SS patients had significantly lower DI scores, less treatment time (∼7 months), and better CRE scores for first-order alignment-rotation and interproximal space closure; however, second-order root angulation (RA) was inferior. SS patients were treated in less time to better CRE scores for first-order rotation (AR) and interproximal space closure (IC) but on the average, malocclusions were less complex and second order root alignment was inferior, compared with patients finished with manual wire bending.
Nawasreh, Zakariya; Logerstedt, David; Failla, Mathew; Snyder-Mackler, Lynn
2017-10-27
Manual perturbation training improves dynamic knee stability and functional performance after anterior cruciate ligament rupture (ACL-rupture). However, it is limited to static standing position and does not allow time-specific perturbations at different phase of functional activities. The purpose of this study was to investigate whether administering mechanical perturbation training including compliant surface provides effects similar to manual perturbation training on knee functional measures after an acute ACL-rupture. Sixteen level I/II athletes with ACL-ruptures participated in this preliminary study. Eight patients received mechanical (Mechanical) and eight subjects received manual perturbation training (Manual). All patients completed a functional testing (isometric quadriceps strength, single-legged hop tests) and patient-reported measures (Knee Outcome Survey-Activities of Daily Living Scale (KOS-ADLS), Global Rating Score (GRS), International Knee Documentation Committee 2000 (IKDC 2000) at pre- and post-training. 2 × 2 ANOVA was used for data analysis. No significant group-by-time interactions were found for all measures (p > 0.18). Main effects of time were found for single hop (Pre-testing: 85.14% ± 21.07; Post-testing: 92.49% ± 17.55), triple hop (Pre-testing: 84.64% ± 14.17; Post-testing: 96.64% ± 11.14), KOS-ADLS (Pre-testing: 81.13% ± 11.12; Post-testing: 88.63% ± 12.63), GRS (Pre-testing: 68.63% ± 15.73; Post-testing: 78.81% ± 13.85), and IKDC 2000 (Pre-testing: 66.66% ± 9.85; Post-testing: 76.05% ± 14.62) (p < 0.032). Administering mechanical perturbation training using compliant surfaces induce effects similar to manual perturbation training on knee functional performance after acute ACL-rupture. The clinical significance is both modes of training improve patients' functional-performance and limb-to-limb movement symmetry, and enhancing the patients' self-reported of knee functional measures after ACL rupture. Mechanical perturbation that provides a compliant surface might be utilized as part of the ACL rehabilitation training. © 2017 Orthopaedic Research Society. Published by Wiley Periodicals, Inc. J Orthop Res. © 2017 Orthopaedic Research Society. Published by Wiley Periodicals, Inc.
ERIC Educational Resources Information Center
Lindsay, Gordon B.; Merrill, Ray M.; Owens, Adam; Barleen, Nathan A.
2008-01-01
Background: There is some debate over the efficacy of alcohol industry parenting manuals. Purpose: This study compares the content and focus of alcohol industry and non-industry "talk to your child about drinking" parenting manuals. Methods: Parenting manuals from Anheuser-Busch and Miller Brewing Company were compared to federal government and…
NASA Astrophysics Data System (ADS)
Barlow, Steven J.
1986-09-01
The Air Force needs a better method of designing new and retrofit heating, ventilating and air conditioning (HVAC) control systems. Air Force engineers currently use manual design/predict/verify procedures taught at the Air Force Institute of Technology, School of Civil Engineering, HVAC Control Systems course. These existing manual procedures are iterative and time-consuming. The objectives of this research were to: (1) Locate and, if necessary, modify an existing computer-based method for designing and analyzing HVAC control systems that is compatible with the HVAC Control Systems manual procedures, or (2) Develop a new computer-based method of designing and analyzing HVAC control systems that is compatible with the existing manual procedures. Five existing computer packages were investigated in accordance with the first objective: MODSIM (for modular simulation), HVACSIM (for HVAC simulation), TRNSYS (for transient system simulation), BLAST (for building load and system thermodynamics) and Elite Building Energy Analysis Program. None were found to be compatible or adaptable to the existing manual procedures, and consequently, a prototype of a new computer method was developed in accordance with the second research objective.
Cerebella segmentation on MR images of pediatric patients with medulloblastoma
NASA Astrophysics Data System (ADS)
Shan, Zu Y.; Ji, Qing; Glass, John; Gajjar, Amar; Reddick, Wilburn E.
2005-04-01
In this study, an automated method has been developed to identify the cerebellum from T1-weighted MR brain images of patients with medulloblastoma. A new objective function that is similar to Gibbs free energy in classic physics was defined; and the brain structure delineation was viewed as a process of minimizing Gibbs free energy. We used a rigid-body registration and an active contour (snake) method to minimize the Gibbs free energy in this study. The method was applied to 20 patient data sets to generate cerebellum images and volumetric results. The generated cerebellum images were compared with two manually drawn results. Strong correlations were found between the automatically and manually generated volumetric results, the correlation coefficients with each of manual results were 0.971 and 0.974, respectively. The average Jaccard similarities with each of two manual results were 0.89 and 0.88, respectively. The average Kappa indexes with each of two manual results were 0.94 and 0.93, respectively. These results showed this method was both robust and accurate for cerebellum segmentation. The method may be applied to various research and clinical investigation in which cerebellum segmentation and quantitative MR measurement of cerebellum are needed.
Kuo, Terry B. J.; Li, Jia-Yi; Lai, Chun-Ting; Huang, Yu-Chun; Hsu, Ya-Chuan; Yang, Cheryl C. H.
2013-01-01
Background. Different types of mattresses affect sleep quality and waking muscle power. Whether manual muscle testing (MMT) predicts the cardiovascular effects of the bedding system was explored using ten healthy young men. Methods. For each participant, two bedding systems, one inducing the strongest limb muscle force (strong bedding system) and the other inducing the weakest limb force (weak bedding system), were identified using MMT. Each bedding system, in total five mattresses and eight pillows of different firmness, was used for two continuous weeks at the participant's home in a random and double-blind sequence. A sleep log, a questionnaire, and a polysomnography were used to differentiate the two bedding systems. Results and Conclusion. Heart rate variability and arterial pressure variability analyses showed that the strong bedding system resulted in decreased cardiovascular sympathetic modulation, increased cardiac vagal activity, and increased baroreceptor reflex sensitivity during sleep as compared to the weak bedding system. Different bedding systems have distinct cardiovascular effects during sleep that can be predicted by MMT. PMID:24371836
Current Space Station Experiments Investigating Component Level Electronics Repair
NASA Technical Reports Server (NTRS)
Easton, John W.; Struk, Peter M.
2010-01-01
The Soldering in a Reduced Gravity Experiment (SoRGE) and Component Repair Experiment (CRE)-1 are tests performed on the International Space Station to determine the techniques, tools, and training necessary to allow future crews to perform manual electronics repairs at the component level. SoRGE provides information on the formation and internal structure of through-hole solder joints, illustrating the challenges and implications of soldering in reduced gravity. SoRGE showed a significant increase in internal void defects for joints formed in low gravity compared to normal gravity. Methods for mitigating these void defects were evaluated using a modified soldering process. CRE-1 demonstrated the removal, cleaning, and replacement of electronics components by manual means on functional circuit boards. The majority of components successful passed a post-repair functional test demonstrating the feasibility of component-level repair within the confines of a spacecraft. Together, these tasks provide information to recommend material and tool improvements, training improvements, and future work to help enable electronics repairs in future space missions.
Yang, Byung Il; Song, Bo Kyoung; Joung, Sang Mi
2017-01-01
[Purpose] The purpose of this study was to determine whether two-handed task training is effective on motor learning of injured cerebral cortex activation and upper extremity function recovery after stroke. [Subjects and Methods] Two hemiplegic subjects participated in this study: one patient was affected on the dominant side of the body and the other was affected on the non-dominant side of the body, and both scored in the range of 58–66 in the Fugl-Meyer assessment. The excitability of the corticospinal tract and Manual Function Test were examined. [Results] The excitability of the corticospinal tract and the Manual Function Test showed significant differences in the activation of both sides of the cerebral cortex and in the variation in learning effect of upper extremity motor function recovery in patients with hemiplegic non-dominant hand (left). [Conclusion] The results suggested that two-handed task training had a different influence on dominant hand (right) and non-dominant hand (left) motor recovery. PMID:28210051
Manual of an Instructional Program in Dental Assisting.
ERIC Educational Resources Information Center
Gilbert, Maud R., Ed.; Fiedler, Belle, Ed.
This manual is for administrator and teacher use in planning a program and individual courses for adults in dental assisting in vocational, technical, and adult programs. The manual was developed by a supervisor, a teacher-coordinator, teachers, and dentists at the local level and tested in the local school. The objectives are to prepare…
Course Manual for X-Ray Applications.
ERIC Educational Resources Information Center
Food and Drug Administration (DHEW), Rockville, MD. Bureau of Radiological Health.
This publication is the third of three sequential course manuals for instructors in x-ray science and engineering. This course manual has been tested by introducing it into the Oregon State University curriculum. The publication is prepared for the purpose of improving the qualifications of x-ray users and to reduce the ionizing radiation exposure…
Huang, Jianyan; Maram, Jyotsna; Tepelus, Tudor C; Modak, Cristina; Marion, Ken; Sadda, SriniVas R; Chopra, Vikas; Lee, Olivia L
2017-08-07
To determine the reliability of corneal endothelial cell density (ECD) obtained by automated specular microscopy versus that of validated manual methods and factors that predict such reliability. Sharp central images from 94 control and 106 glaucomatous eyes were captured with Konan specular microscope NSP-9900. All images were analyzed by trained graders using Konan CellChek Software, employing the fully- and semi-automated methods as well as Center Method. Images with low cell count (input cells number <100) and/or guttata were compared with the Center and Flex-Center Methods. ECDs were compared and absolute error was used to assess variation. The effect on ECD of age, cell count, cell size, and cell size variation was evaluated. No significant difference was observed between the Center and Flex-Center Methods in corneas with guttata (p=0.48) or low ECD (p=0.11). No difference (p=0.32) was observed in ECD of normal controls <40 yrs old between the fully-automated method and manual Center Method. However, in older controls and glaucomatous eyes, ECD was overestimated by the fully-automated method (p=0.034) and semi-automated method (p=0.025) as compared to manual method. Our findings show that automated analysis significantly overestimates ECD in the eyes with high polymegathism and/or large cell size, compared to the manual method. Therefore, we discourage reliance upon the fully-automated method alone to perform specular microscopy analysis, particularly if an accurate ECD value is imperative. Copyright © 2017. Published by Elsevier España, S.L.U.
Segmentation of tumor ultrasound image in HIFU therapy based on texture and boundary encoding
NASA Astrophysics Data System (ADS)
Zhang, Dong; Xu, Menglong; Quan, Long; Yang, Yan; Qin, Qianqing; Zhu, Wenbin
2015-02-01
It is crucial in high intensity focused ultrasound (HIFU) therapy to detect the tumor precisely with less manual intervention for enhancing the therapy efficiency. Ultrasound image segmentation becomes a difficult task due to signal attenuation, speckle effect and shadows. This paper presents an unsupervised approach based on texture and boundary encoding customized for ultrasound image segmentation in HIFU therapy. The approach oversegments the ultrasound image into some small regions, which are merged by using the principle of minimum description length (MDL) afterwards. Small regions belonging to the same tumor are clustered as they preserve similar texture features. The mergence is completed by obtaining the shortest coding length from encoding textures and boundaries of these regions in the clustering process. The tumor region is finally selected from merged regions by a proposed algorithm without manual interaction. The performance of the method is tested on 50 uterine fibroid ultrasound images from HIFU guiding transducers. The segmentations are compared with manual delineations to verify its feasibility. The quantitative evaluation with HIFU images shows that the mean true positive of the approach is 93.53%, the mean false positive is 4.06%, the mean similarity is 89.92%, the mean norm Hausdorff distance is 3.62% and the mean norm maximum average distance is 0.57%. The experiments validate that the proposed method can achieve favorable segmentation without manual initialization and effectively handle the poor quality of the ultrasound guidance image in HIFU therapy, which indicates that the approach is applicable in HIFU therapy.
The manual lists and describes the instruments and techniques that are available for measuring the concentration or size distribution of particles suspended in process streams. The standard, official, well established methods are described as well as some experimental methods and...
Instrumental and Non-Instrumental Evaluation of 4-Meter Walking Speed in Older Individuals
Maggio, Marcello; Ceda, Gian Paolo; Ticinesi, Andrea; De Vita, Francesca; Gelmini, Giovanni; Costantino, Cosimo; Meschi, Tiziana; Kressig, Reto W.; Cesari, Matteo; Fabi, Massimo; Lauretani, Fulvio
2016-01-01
Background Manual measurement of 4-meter gait speed by a stopwatch is the gold standard test for functional assessment in older adults. However, the accuracy of this technique may be biased by several factors, including intra- and inter-operator variability. Instrumental techniques of measurement using accelerometers may have a higher accuracy. Studies addressing the concordance between these two techniques are missing. The aim of the present community-based observational study was to compare manual and instrumental measurements of 4-meter gait speed in older individuals and to assess their relationship with other indicators of physical performance. Methods One-hundred seventy-two (69 men, 103 women) non-disabled community-dwellers aged ≥65 years were enrolled. They underwent a comprehensive geriatric assessment including physical function by Short Physical Performance Battery (SPPB), hand grip strength, and 6-minute walking test (6MWT). Timed usual walking speed on a 4-meter course was assessed by using both a stopwatch (4-meter manual measurement, 4-MM) and a tri-axial accelerometer (4-meter automatic measurement, 4-MA). Correlations between these performance measures were evaluated separately in men and women by partial correlation coefficients. Results In both genders, 4-MA was associated with 4-MM (men r = 0.62, p<0.001; women r = 0.73, p<0.001), handgrip strength (men r = 0.40, p = 0.005; women r = 0.29, p = 0.001) and 6MWT (men r = 0.50, p = 0.0004; women r = 0.22, p = 0.048). 4-MM was associated with handgrip strength and 6MWT in both men and women. Considering gait speed <0.6 m/s as diagnostic of dismobility syndrome, the two methods of assessment disagreed, with a different categorization of subjects, in 19% of men and 23% of women. The use of accelerometer resulted in 29 (13 M, 16 F) additional diagnoses of dismobility, compared with the 4-MM. Conclusions In an older population, the concordance of gait speeds manually or instrumentally assessed is not optimal. The results suggest that manual measures might lead to misclassification of a substantial number of subjects. However, longitudinal studies using standardized and validated procedures aimed at the comparison of different techniques are needed before recommending the use of accelerometers in comprehensive geriatric assessment. PMID:27077744
1978-09-01
iE ARI TECHNICAL REPORT S~ TR-78-A31 M CCriterion-Reforencod Loasurement In the Army: Development of a Research-Based, Practical, Test Construction ...conducted to develop a Criterion- 1 Referenced Tests (CRTs) Construction Manual. Major accomplishments were the preparation of a written review of the...survey of the literature on Criterion-Referenced Testing’ conducted in order to provide an information base for development of the CRT Construction
Wallace, F Morgan; DiCosimo, Deana; Farnum, Andrew; Tice, George; Andaloro, Bridget; Davis, Eugene; Burns, Frank R
2011-01-01
In 2010, the BAX System PCR assay for Salmonella was modified to include a hot start functionality designed to keep the reaction enzyme inactive until PCR begins. To validate the assay's Official Methods of Analysis status to include this procedure modification, an evaluation was conducted on four food types that were simultaneously analyzed with the BAX System and either the U.S. Food and Drug Administration's Bacteriological Analytical Manual or the U.S. Department of Agriculture-Food Safety and Inspection Service Microbiology Laboratory Guidebook reference method for detecting Salmonella. Identical performance between the BAX System method and the reference methods was observed. Additionally, lysates were analyzed using both the BAX System Classic and BAX System Q7 instruments with identical results using both platforms for all samples tested. Of the 100 samples analyzed, 34 samples were positive for both the BAX System and reference methods, and 66 samples were negative by both the BAX System and reference methods, demonstrating 100% correlation. No instrument platform variation was observed. Additional inclusivity and exclusivity testing using the modified test kit demonstrated the test kit to be 100% accurate in evaluation of test panels of 352 Salmonella strains and 46 non-Salmonella strains.
Zhou, Guang-Quan; Chan, Phoebe; Zheng, Yong-Ping
2015-03-01
Muscle imaging is a promising field of research to understand the biological and bioelectrical characteristics of muscles through the observation of muscle architectural change. Sonomyography (SMG) is a technique which can quantify the real-time architectural change of muscles under different contractions and motions with ultrasound imaging. The pennation angle and fascicle length are two crucial SMG parameters to understand the contraction mechanics at muscle level, but they have to be manually detected on ultrasound images frame by frame. In this study, we proposed an automatic method to quantitatively identify pennation angle and fascicle length of gastrocnemius (GM) muscle based on multi-resolution analysis and line feature extraction, which could overcome the limitations of tedious and time-consuming manual measurement. The method started with convolving Gabor wavelet specially designed for enhancing the line-like structure detection in GM ultrasound image. The resulting image was then used to detect the fascicles and aponeuroses for calculating the pennation angle and fascicle length with the consideration of their distribution in ultrasound image. The performance of this method was tested on computer simulated images and experimental images in vivo obtained from normal subjects. Tests on synthetic images showed that the method could identify the fascicle orientation with an average error less than 0.1°. The result of in vivo experiment showed a good agreement between the results obtained by the automatic and the manual measurements (r=0.94±0.03; p<0.001, and r=0.95±0.02, p<0.001). Furthermore, a significant correlation between the ankle angle and pennation angle (r=0.89±0.05; p<0.001) and fascicle length (r=-0.90±0.04; p<0.001) was found for the ankle plantar flexion. This study demonstrated that the proposed method was able to automatically measure the pennation angle and fascicle length of GM ultrasound images, which made it feasible to investigate muscle-level mechanics more comprehensively in vivo. Copyright © 2014 Elsevier B.V. All rights reserved.
Bird, Patrick; Benzinger, M Joseph; Bastin, Benjamin; Crowley, Erin; Agin, James; Goins, David; Armstrong, Marcia
2018-05-01
QIAGEN mericon Escherichia coli O157 Screen Plus and mericon E. coli Shiga toxin-producing E. coli (STEC) O-Type Pathogen Detection Assays use Real-Time PCR technology for the rapid, accurate detection of E. coli O157 and the "big six" (O26, O45, O103, O111, O121, O145) (non-O157 STEC) in select food types. Using a paired study design, the assays were compared with the U.S. Department of Agriculture, Food Safety Inspection Service Microbiology Laboratory Guidebook Chapter 5.09 reference method for the detection of E. coli O157:H7 in raw ground beef. Both mericon assays were evaluated using the manual and an automated DNA extraction method. Thirteen technicians from five laboratories located within the continental United States participated in the collaborative study. Three levels of contamination were evaluated. Statistical analysis was conducted according to the probability of detection (POD) statistical model. Results obtained for the low-inoculum level test portions produced a difference between laboratories POD (dLPOD) value with a 95% confidence interval of 0.00 (-0.12, 0.12) for the mericon E. coli O157 Screen Plus with manual and automated extraction and mericon E. coli STEC O-Type with manual extraction and -0.01 (-0.13, 0.10) for the mericon E. coli STEC O-Type with automated extraction. The dLPOD results indicate equivalence between the candidate methods and the reference method.
NASA Astrophysics Data System (ADS)
Patel, Ajay; van de Leemput, Sil C.; Prokop, Mathias; van Ginneken, Bram; Manniesing, Rashindra
2017-03-01
Segmentation of anatomical structures is fundamental in the development of computer aided diagnosis systems for cerebral pathologies. Manual annotations are laborious, time consuming and subject to human error and observer variability. Accurate quantification of cerebrospinal fluid (CSF) can be employed as a morphometric measure for diagnosis and patient outcome prediction. However, segmenting CSF in non-contrast CT images is complicated by low soft tissue contrast and image noise. In this paper we propose a state-of-the-art method using a multi-scale three-dimensional (3D) fully convolutional neural network (CNN) to automatically segment all CSF within the cranial cavity. The method is trained on a small dataset comprised of four manually annotated cerebral CT images. Quantitative evaluation of a separate test dataset of four images shows a mean Dice similarity coefficient of 0.87 +/- 0.01 and mean absolute volume difference of 4.77 +/- 2.70 %. The average prediction time was 68 seconds. Our method allows for fast and fully automated 3D segmentation of cerebral CSF in non-contrast CT, and shows promising results despite a limited amount of training data.
ERIC Educational Resources Information Center
Todd, Richard D.; Huang, Hongyan; Henderson, Cynthia A.
2008-01-01
Background: To test whether the retrospective reporting of the age of onset impairment criterion for attention deficit/hyperactivity disorder (ADHD) required in the "Diagnostic and Statistical Manual of Mental Disorders-IV" (DSM-IV) complicates identification of new and known child and adolescent cases later in life. Methods: A birth-records-based…
User's Manual. Vocational Education Readiness Test (VERT). Revised Edition.
ERIC Educational Resources Information Center
Thomas, Edward L.; And Others
This user's manual provides information suggesting various ways in which educational personnel may wish to utilize the eight modules included in the Vocational Education Readiness Test (VERT). The introductory section presents questions which can be used by school personnel to determine whether or not VERT will be useful in their school system.…
Petrographic methods of examining hardened concrete : a petrographic manual.
DOT National Transportation Integrated Search
1997-11-01
This manual was undertaken to record for all persons wishing to do concrete : petrography the petrographic procedures that have been found useful at the : Virginia Transportation Research Council. The manual is made up of an : introduction and chapte...
Calibration of highway safety manual work zone crash modification factors.
DOT National Transportation Integrated Search
2014-06-01
The Highway Safety Manual is the national safety manual that provides quantitative methods for analyzing highway safety. The : HSM presents crash modification factors related to work zone characteristics such as work zone duration and length. These c...
Fully automatic segmentation of fluorescein leakage in subjects with diabetic macular edema.
Rabbani, Hossein; Allingham, Michael J; Mettu, Priyatham S; Cousins, Scott W; Farsiu, Sina
2015-01-29
To create and validate software to automatically segment leakage area in real-world clinical fluorescein angiography (FA) images of subjects with diabetic macular edema (DME). Fluorescein angiography images obtained from 24 eyes of 24 subjects with DME were retrospectively analyzed. Both video and still-frame images were obtained using a Heidelberg Spectralis 6-mode HRA/OCT unit. We aligned early and late FA frames in the video by a two-step nonrigid registration method. To remove background artifacts, we subtracted early and late FA frames. Finally, after postprocessing steps, including detection and inpainting of the vessels, a robust active contour method was utilized to obtain leakage area in a 1500-μm-radius circular region centered at the fovea. Images were captured at different fields of view (FOVs) and were often contaminated with outliers, as is the case in real-world clinical imaging. Our algorithm was applied to these images with no manual input. Separately, all images were manually segmented by two retina specialists. The sensitivity, specificity, and accuracy of manual interobserver, manual intraobserver, and automatic methods were calculated. The mean accuracy was 0.86 ± 0.08 for automatic versus manual, 0.83 ± 0.16 for manual interobserver, and 0.90 ± 0.08 for manual intraobserver segmentation methods. Our fully automated algorithm can reproducibly and accurately quantify the area of leakage of clinical-grade FA video and is congruent with expert manual segmentation. The performance was reliable for different DME subtypes. This approach has the potential to reduce time and labor costs and may yield objective and reproducible quantitative measurements of DME imaging biomarkers. Copyright 2015 The Association for Research in Vision and Ophthalmology, Inc.
Qu, Zhenhong; Ghorbani, Rhonda P; Li, Hongyan; Hunter, Robert L; Hannah, Christina D
2007-03-01
Gross examination, encompassing description, dissection, and sampling, is a complex task and an essential component of surgical pathology. Because of the complexity of the task, standardized protocols to guide the gross examination often become a bulky manual that is difficult to use. This problem is further compounded by the high specimen volume and biohazardous nature of the task. As a result, such a manual is often underused, leading to errors that are potentially harmful and time consuming to correct-a common chronic problem affecting many pathology laboratories. To combat this problem, we have developed a simple method that incorporates complex text and graphic information of a typical procedure manual and yet allows easy access to any intended instructive information in the manual. The method uses the Object-Linking-and-Embedding function of Microsoft Word (Microsoft, Redmond, WA) to establish hyperlinks among different contents, and then it uses the touch screen technology to facilitate navigation through the manual on a computer screen installed at the cutting bench with no need for a physical keyboard or a mouse. It takes less than 4 seconds to reach any intended information in the manual by 3 to 4 touches on the screen. A 3-year follow-up study shows that this method has increased use of the manual and has improved the quality of gross examination. The method is simple and can be easily tailored to different formats of instructive information, allowing flexible organization, easy access, and quick navigation. Increased compliance to instructive information reduces errors at the grossing bench and improves work efficiency.
Trehan, Mridula; Sharma, Sunil; Jharwal, Vikas; Rathore, Nidhi
2015-01-01
ABSTRACT Introduction: Maintenance of good oral hygiene is important for patients undergoing fixed orthodontic treatment. Aim: The aim of this study was to evaluate the effectiveness of a manual orthodontic toothbrush, powered toothbrush with oscillating head and sonic toothbrush in controlling plaque, gingivitis and interdental bleeding in patients undergoing fixed orthodontic treatment, and to compare their relative efficacy. Materials and methods: Sixty subjects, who were to receive orthodontic treatment with both upper and lower fixed appliances, were randomly divided into three study groups, with 20 patients in each group. Groups I to III were given manual orthodontic, powered and sonic toothbrushes, respectively. Plaque index (PI), gingival index (GI) and interdental bleeding index were scored to assess the level of plaque accumulation, gingival health and interdental bleeding at baseline; 4 and 8 weeks recall visits after fixed appliance bonding. Paired t-tests and one-way analysis of variance (ANOVA) tests were used for intragroup and intergroup comparisons. The level of statistical significance was set at p < 0.05. Results: This study showed that a significant reduction in all the three indices scores was found from baseline to 4 and 8 weeks in group III. On intergroup comparison, no statistically significant differences were detected between the three groups for any of the parameters assessed. Conclusion: On intragroup comparison, sonic brushes performed superiorly in reducing gingivitis, plaque and interdental bleeding as compared to the manual orthodontic and powered brushes. On intergroup comparison, the relative comparative effectiveness was found to be similar for all the three brushes. How to cite this article: Sharma R, Trehan M, Sharma S, Jharwal V, Rathore N. Comparison of Effectiveness of Manual Orthodontic, Powered and Sonic Toothbrushes on Oral Hygiene of Fixed Orthodontic Patients. Int J Clin Pediatr Dent 2015;8(3):181-189. PMID:26628852
Application of surface geophysics to ground-water investigations
Zohdy, Adel A.R.; Eaton, Gordon P.; Mabey, Don R.
1974-01-01
This manual reviews the standard methods of surface geophysics applicable to ground-water investigations. It covers electrical methods, seismic and gravity methods, and magnetic methods. The general physical principles underlying each method and its capabilities and limitations are described. Possibilities for non-uniqueness of interpretation of geophysical results are noted. Examples of actual use of the methods are given to illustrate applications and interpretation in selected geohydrologic environments. The objective of the manual is to provide the hydrogeologist with a sufficient understanding of the capabilities, imitations, and relative cost of geophysical methods to make sound decisions as to when to use of these methods is desirable. The manual also provides enough information for the hydrogeologist to work with a geophysicist in designing geophysical surveys that differentiate significant hydrogeologic changes.
Mulder, Emma R; de Jong, Remko A; Knol, Dirk L; van Schijndel, Ronald A; Cover, Keith S; Visser, Pieter J; Barkhof, Frederik; Vrenken, Hugo
2014-05-15
To measure hippocampal volume change in Alzheimer's disease (AD) or mild cognitive impairment (MCI), expert manual delineation is often used because of its supposed accuracy. It has been suggested that expert outlining yields poorer reproducibility as compared to automated methods, but this has not been investigated. To determine the reproducibilities of expert manual outlining and two common automated methods for measuring hippocampal atrophy rates in healthy aging, MCI and AD. From the Alzheimer's Disease Neuroimaging Initiative (ADNI), 80 subjects were selected: 20 patients with AD, 40 patients with mild cognitive impairment (MCI) and 20 healthy controls (HCs). Left and right hippocampal volume change between baseline and month-12 visit was assessed by using expert manual delineation, and by the automated software packages FreeSurfer (longitudinal processing stream) and FIRST. To assess reproducibility of the measured hippocampal volume change, both back-to-back (BTB) MPRAGE scans available for each visit were analyzed. Hippocampal volume change was expressed in μL, and as a percentage of baseline volume. Reproducibility of the 1-year hippocampal volume change was estimated from the BTB measurements by using linear mixed model to calculate the limits of agreement (LoA) of each method, reflecting its measurement uncertainty. Using the delta method, approximate p-values were calculated for the pairwise comparisons between methods. Statistical analyses were performed both with inclusion and exclusion of visibly incorrect segmentations. Visibly incorrect automated segmentation in either one or both scans of a longitudinal scan pair occurred in 7.5% of the hippocampi for FreeSurfer and in 6.9% of the hippocampi for FIRST. After excluding these failed cases, reproducibility analysis for 1-year percentage volume change yielded LoA of ±7.2% for FreeSurfer, ±9.7% for expert manual delineation, and ±10.0% for FIRST. Methods ranked the same for reproducibility of 1-year μL volume change, with LoA of ±218 μL for FreeSurfer, ±319 μL for expert manual delineation, and ±333 μL for FIRST. Approximate p-values indicated that reproducibility was better for FreeSurfer than for manual or FIRST, and that manual and FIRST did not differ. Inclusion of failed automated segmentations led to worsening of reproducibility of both automated methods for 1-year raw and percentage volume change. Quantitative reproducibility values of 1-year microliter and percentage hippocampal volume change were roughly similar between expert manual outlining, FIRST and FreeSurfer, but FreeSurfer reproducibility was statistically significantly superior to both manual outlining and FIRST after exclusion of failed segmentations. Copyright © 2014 Elsevier Inc. All rights reserved.
Plaster, Ralph; Vieira, Wellington Bueno; Alencar, Flávia Alves Duarte; Nakano, Eduardo Yoshio; Liebano, Richard Eloin
2014-06-01
To compare the immediate effects of electroacupuncture and manual acupuncture on pain, mobility and muscle strength in patients with knee osteoarthritis. Sixty patients with knee osteoarthritis, with a pain intensity of ≥2 on the pain Numerical Rating Scale, were included. The patients were randomised into two groups: manual acupuncture and electroacupuncture. Pain intensity, degree of dysfunction (Timed Up and Go (TUG) test), maximal voluntary isometric contraction and pressure pain threshold were assessed before and after a single session of manual acupuncture or electroacupuncture treatments. Both groups showed a significant reduction in pain intensity (p<0.001) and time to run the TUG test after the acupuncture treatment (p=0.005 for the manual acupuncture group and p=0.002 for the electroacupuncture group). There were no differences between the groups regarding pain intensity (p=0.25), TUG test (p=0.70), maximum voluntary isometric contraction (p=0.43) or pressure pain threshold (p=0.27). This study found no difference between the immediate effects of a single session of manual acupuncture and electroacupuncture on pain, muscle strength and mobility in patients with knee osteoarthritis. RBR-9TCN2X. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://group.bmj.com/group/rights-licensing/permissions.
Automated brainstem co-registration (ABC) for MRI.
Napadow, Vitaly; Dhond, Rupali; Kennedy, David; Hui, Kathleen K S; Makris, Nikos
2006-09-01
Group data analysis in brainstem neuroimaging is predicated on accurate co-registration of anatomy. As the brainstem is comprised of many functionally heterogeneous nuclei densely situated adjacent to one another, relatively small errors in co-registration can manifest in increased variance or decreased sensitivity (or significance) in detecting activations. We have devised a 2-stage automated, reference mask guided registration technique (Automated Brainstem Co-registration, or ABC) for improved brainstem co-registration. Our approach utilized a brainstem mask dataset to weight an automated co-registration cost function. Our method was validated through measurement of RMS error at 12 manually defined landmarks. These landmarks were also used as guides for a secondary manual co-registration option, intended for outlier individuals that may not adequately co-register with our automated method. Our methodology was tested on 10 healthy human subjects and compared to traditional co-registration techniques (Talairach transform and automated affine transform to the MNI-152 template). We found that ABC had a significantly lower mean RMS error (1.22 +/- 0.39 mm) than Talairach transform (2.88 +/- 1.22 mm, mu +/- sigma) and the global affine (3.26 +/- 0.81 mm) method. Improved accuracy was also found for our manual-landmark-guided option (1.51 +/- 0.43 mm). Visualizing individual brainstem borders demonstrated more consistent and uniform overlap for ABC compared to traditional global co-registration techniques. Improved robustness (lower susceptibility to outliers) was demonstrated with ABC through lower inter-subject RMS error variance compared with traditional co-registration methods. The use of easily available and validated tools (AFNI and FSL) for this method should ease adoption by other investigators interested in brainstem data group analysis.
Validity of Automated Choroidal Segmentation in SS-OCT and SD-OCT.
Zhang, Li; Buitendijk, Gabriëlle H S; Lee, Kyungmoo; Sonka, Milan; Springelkamp, Henriët; Hofman, Albert; Vingerling, Johannes R; Mullins, Robert F; Klaver, Caroline C W; Abràmoff, Michael D
2015-05-01
To evaluate the validity of a novel fully automated three-dimensional (3D) method capable of segmenting the choroid from two different optical coherence tomography scanners: swept-source OCT (SS-OCT) and spectral-domain OCT (SD-OCT). One hundred eight subjects were imaged using SS-OCT and SD-OCT. A 3D method was used to segment the choroid and quantify the choroidal thickness along each A-scan. The segmented choroidal posterior boundary was evaluated by comparing to manual segmentation. Differences were assessed to test the agreement between segmentation results of the same subject. Choroidal thickness was defined as the Euclidian distance between Bruch's membrane and the choroidal posterior boundary, and reproducibility was analyzed using automatically and manually determined choroidal thicknesses. For SS-OCT, the average choroidal thickness of the entire 6- by 6-mm2 macular region was 219.5 μm (95% confidence interval [CI], 204.9-234.2 μm), and for SD-OCT it was 209.5 μm (95% CI, 197.9-221.0 μm). The agreement between automated and manual segmentations was high: Average relative difference was less than 5 μm, and average absolute difference was less than 15 μm. Reproducibility of choroidal thickness between repeated SS-OCT scans was high (coefficient of variation [CV] of 3.3%, intraclass correlation coefficient [ICC] of 0.98), and differences between SS-OCT and SD-OCT results were small (CV of 11.0%, ICC of 0.73). We have developed a fully automated 3D method for segmenting the choroid and quantifying choroidal thickness along each A-scan. The method yielded high validity. Our method can be used reliably to study local choroidal changes and may improve the diagnosis and management of patients with ocular diseases in which the choroid is affected.