Simpson, G S; Eardley, N; McNicol, F; Healey, P; Hughes, M; Rooney, P S
2014-05-01
The management of rectal cancer relies on accurate MRI staging. Multi-modal treatments can downstage rectal cancer prior to surgery and may have an effect on MRI accuracy. We aim to correlate the findings of MRI staging of rectal cancer with histological analysis, the effect of neoadjuvant therapy on this and the implications of circumferential resection margin (CRM) positivity following neoadjuvant therapy. An analysis of histological data and radiological staging of all cases of rectal cancer in a single centre between 2006 and 2011 were conducted. Two hundred forty-one patients had histologically proved rectal cancer during the study period. One hundred eighty-two patients underwent resection. Median age was 66.6 years, and male to female ratio was 13:5. R1 resection rate was 11.1%. MRI assessments of the circumferential resection margin in patients without neoadjuvant radiotherapy were 93.6 and 88.1% in patients who underwent neoadjuvant radiotherapy. Eighteen patients had predicted positive margins following chemoradiotherapy, of which 38.9% had an involved CRM on histological analysis. MRI assessment of the circumferential resection margin in rectal cancer is associated with high accuracy. Neoadjuvant chemoradiotherapy has a detrimental effect on this accuracy, although accuracy remains high. In the presence of persistently predicted positive margins, complete resection remains achievable but may necessitate a more radical approach to resection.
Different CAD/CAM-processing routes for zirconia restorations: influence on fitting accuracy.
Kohorst, Philipp; Junghanns, Janet; Dittmer, Marc P; Borchers, Lothar; Stiesch, Meike
2011-08-01
The aim of the present in vitro study was to evaluate the influence of different processing routes on the fitting accuracy of four-unit zirconia fixed dental prostheses (FDPs) fabricated by computer-aided design/computer-aided manufacturing (CAD/CAM). Three groups of zirconia frameworks with ten specimens each were fabricated. Frameworks of one group (CerconCAM) were produced by means of a laboratory CAM-only system. The other frameworks were made with different CAD/CAM systems; on the one hand by in-laboratory production (CerconCAD/CAM) and on the other hand by centralized production in a milling center (Compartis) after forwarding geometrical data. Frameworks were then veneered with the recommended ceramics, and marginal accuracy was determined using a replica technique. Horizontal marginal discrepancy, vertical marginal discrepancy, absolute marginal discrepancy, and marginal gap were evaluated. Statistical analyses were performed by one-way analysis of variance (ANOVA), with the level of significance chosen at 0.05. Mean horizontal discrepancies ranged between 22 μm (CerconCAM) and 58 μm (Compartis), vertical discrepancies ranged between 63 μm (CerconCAD/CAM) and 162 μm (CerconCAM), and absolute marginal discrepancies ranged between 94 μm (CerconCAD/CAM) and 181 μm (CerconCAM). The marginal gap varied between 72 μm (CerconCAD/CAM) and 112 μm (CerconCAM, Compartis). Statistical analysis revealed that, with all measurements, the marginal accuracy of the zirconia FDPs was significantly influenced by the processing route used (p < 0.05). Within the limitations of this study, all restorations showed a clinically acceptable marginal accuracy; however, the results suggest that the CAD/CAM systems are more precise than the CAM-only system for the manufacture of four-unit FDPs.
Patil, Abhijit; Singh, Kishan; Sahoo, Sukant; Suvarna, Suraj; Kumar, Prince; Singh, Anupam
2013-01-01
Objective: The aims of the study are to assess the marginal accuracy of base metal and titanium alloy casting and to evaluate the effect of repeated ceramic firing on the marginal accuracy of base metal and titanium alloy castings. Materials and Methods: Twenty metal copings were fabricated with each casting material. Specimens were divided into 4 groups of 10 each representing base metal alloys castings without (Group A) and with metal shoulder margin (Group B), titanium castings without (Group C) and with metal shoulder margin (Group D). The measurement of fit of the metal copings was carried out before the ceramic firing at four different points and the same was followed after porcelain build-up. Results: Significant difference was found when Ni–Cr alloy samples were compared with Grade II titanium samples both before and after ceramic firings. The titanium castings with metal shoulder margin showed highest microgap among all the materials tested. Conclusions: Based on the results that were found and within the limitations of the study design, it can be concluded that there is marginal discrepancy in the copings made from Ni–Cr and Grade II titanium. This marginal discrepancy increased after ceramic firing cycles for both Ni–Cr and Grade II titanium. The comparative statistical analysis for copings with metal-collar showed maximum discrepancy for Group D. The comparative statistical analysis for copings without metal-collar showed maximum discrepancy for Group C. PMID:24926205
NASA Technical Reports Server (NTRS)
Orme, John S.; Schkolnik, Gerard S.
1995-01-01
Performance Seeking Control (PSC), an onboard, adaptive, real-time optimization algorithm, relies upon an onboard propulsion system model. Flight results illustrated propulsion system performance improvements as calculated by the model. These improvements were subject to uncertainty arising from modeling error. Thus to quantify uncertainty in the PSC performance improvements, modeling accuracy must be assessed. A flight test approach to verify PSC-predicted increases in thrust (FNP) and absolute levels of fan stall margin is developed and applied to flight test data. Application of the excess thrust technique shows that increases of FNP agree to within 3 percent of full-scale measurements for most conditions. Accuracy to these levels is significant because uncertainty bands may now be applied to the performance improvements provided by PSC. Assessment of PSC fan stall margin modeling accuracy was completed with analysis of in-flight stall tests. Results indicate that the model overestimates the stall margin by between 5 to 10 percent. Because PSC achieves performance gains by using available stall margin, this overestimation may represent performance improvements to be recovered with increased modeling accuracy. Assessment of thrust and stall margin modeling accuracy provides a critical piece for a comprehensive understanding of PSC's capabilities and limitations.
Marginal adaptation of four inlay casting waxes on stone, titanium, and zirconia dies.
Michalakis, Konstantinos X; Kapsampeli, Vassiliki; Kitsou, Aikaterini; Kirmanidou, Yvone; Fotiou, Anna; Pissiotis, Argirios L; Calvani, Pasquale Lino; Hirayama, Hiroshi; Kudara, Yukio
2014-07-01
Different inlay casting waxes do not produce copings with satisfactory marginal accuracy when used on different die materials. The purpose of this study was to evaluate the marginal accuracy of 4 inlay casting waxes on stone dies and titanium and zirconia abutments and to correlate the findings with the degree of wetting between the die specimens and the inlay casting waxes. The inlay casting waxes tested were Starwax (Dentaurum), Unterziehwachs (Bredent), SU Esthetic wax (Schuler), and Sculpturing wax (Renfert). The marginal opening of the waxes was measured with a stereomicroscope on high-strength stone dies and on titanium and zirconia abutments. Photographic images were obtained, and the mean marginal opening for each specimen was calculated. A total of 1440 measurements were made. Wetting between die materials and waxes was determined after fabricating stone, titanium, and zirconia rectangular specimens. A calibrated pipette was used to place a drop of molten wax onto each specimen. The contact angle was calculated with software after an image of each specimen had been made with a digital camera. Collected data were subjected to a 2-way analysis of variance (α=.05). Any association between marginal accuracy and wetting of different materials was found by using the Pearson correlation. The wax factor had a statistically significant effect both on the marginal discrepancy (F=158.31, P<.001) and contact angle values (F=68.09, P<.001). A statistically significant effect of the die material factor both on the marginal adaptation (F=503.47, P<.001) and contact angle values (F=585.02, P<.001) was detected. A significant correlation between the marginal accuracy and the contact angle values (Pearson=0.881, P=.01) was also found. Stone dies provided wax copings with the best marginal integrity, followed by titanium and zirconia abutments. Unterziehwachs (Bredent), wax produced the best marginal adaptation on different die materials. A significant correlation was found between the marginal accuracy and the contact angle values. As the contact angle value became smaller, the marginal accuracy improved. All combinations of waxes and stone and titanium dies presented a high wettability. Copyright © 2014 Editorial Council for the Journal of Prosthetic Dentistry. Published by Elsevier Inc. All rights reserved.
Role of specimen US for predicting resection margin status in breast conserving therapy.
Moschetta, M; Telegrafo, M; Introna, T; Coi, L; Rella, L; Ranieri, V; Cirili, A; Stabile Ianora, A A; Angelelli, G
2015-01-01
To assess the diagnostic accuracy of specimen ultrasound (US) for predicting resection margin status in women undergoing breast conserving therapy for US-detected cancer, having the histological findings as the reference standard. A total of 132 consecutive patients (age range, 34-87 years; mean, 51 years) underwent breast-conserving surgery for US-detected invasive breast cancer. All surgical specimens underwent US examination. The presence of lesion within the specimen and its distance from the specimen margins were assessed considering a threshold distance between the lesion and specimen margins of 10 mm. US findings were then compared with the pathological ones and specimen US. Sensitivity, specificity, diagnostic accuracy, positive (PPV) and negative predictive values (NPV) for predicting histological margin status were evaluated, having the histological findings as the reference standard. The histological examination detected invasive ductal carcinoma in 96/132 (73%) cases, invasive lobular carcinoma in 32/132 (24%), mucinous carcinoma in 4/132 (3%). The pathological margin analysis revealed 96/132 (73%) negative margins and 36 (27%) close/positive margins. US examination detected all 132 breast lesions within the surgical specimens. 110 (83%) negative margins and 22 (17%) positive margins were found on US. Sensitivity, specificity, diagnostic accuracy, PPV and NPV of 44%, 94%, 80%, 73% and 82%, respectively, were found for specimen US. Specimen US represents a time and cost saving imaging tool for evaluating the presence of US detected-breast lesion within surgical specimen and for predicting the histological margin status.
Role of specimen US for predicting resection margin status in breast conserving therapy
MOSCHETTA, M.; TELEGRAFO, M.; INTRONA, T.; COI, L.; RELLA, L.; RANIERI, V.; CIRILLI, A.; IANORA, A.A. STABILE; ANGELELLI, G.
2015-01-01
Aim To assess the diagnostic accuracy of specimen ultrasound (US) for predicting resection margin status in women undergoing breast conserving therapy for US-detected cancer, having the histological findings as the reference standard. Patients and methods A total of 132 consecutive patients (age range, 34–87 years; mean, 51 years) underwent breast-conserving surgery for US-detected invasive breast cancer. All surgical specimens underwent US examination. The presence of lesion within the specimen and its distance from the specimen margins were assessed considering a threshold distance between the lesion and specimen margins of 10 mm. US findings were then compared with the pathological ones and specimen US. Sensitivity, specificity, diagnostic accuracy, positive (PPV) and negative predictive values (NPV) for predicting histological margin status were evaluated, having the histological findings as the reference standard. Results The histological examination detected invasive ductal carcinoma in 96/132 (73%) cases, invasive lobular carcinoma in 32/132 (24%), mucinous carcinoma in 4/132 (3%). The pathological margin analysis revealed 96/132 (73%) negative margins and 36 (27%) close/positive margins. US examination detected all 132 breast lesions within the surgical specimens. 110 (83%) negative margins and 22 (17%) positive margins were found on US. Sensitivity, specificity, diagnostic accuracy, PPV and NPV of 44%, 94%, 80%, 73% and 82%, respectively, were found for specimen US. Conclusions Specimen US represents a time and cost saving imaging tool for evaluating the presence of US detected-breast lesion within surgical specimen and for predicting the histological margin status. PMID:26712255
Juntavee, Niwut; Sirisathit, Issarawas
2018-01-01
This study evaluated marginal accuracy of full-arch zirconia restoration fabricated from two digital computer-aided design and computer-aided manufacturing (CAD-CAM) systems (Trios-3 and CS3500) in comparison to conventional cast metal restoration. A stainless steel model comprising two canine and two molar abutments was used as a master model for full-arch reconstruction. The canine and molar abutments were machined in a cylindrical shape with 5° taper and chamfer margin. The CAD-CAM systems based on the digital approach were used to construct the full-arch zirconia restoration. The conventional cast metal restoration was fabricated according to a conventional lost-wax technique using nickel-chromium alloys. Ten restorations were fabricated from each system. The marginal accuracy of each restoration was determined at four locations for each abutment. An analysis of variance (ANOVA) and Tukey's honest significant difference (HSD) multiple comparisons were used to determine statistically significant difference at 95% confidence interval. The mean values of marginal accuracy of restorations fabricated from conventional casting, Trios-3, and CS3500 were 48.59±4.16 μm, 53.50±5.66 μm, and 56.47±5.52 μm, respectively. ANOVA indicated significant difference in marginal fit of restorations among various systems. The marginal discrepancy of zirconia restoration fabricated from the CS3500 system demonstrated significantly larger gap than that fabricated from the 3Shape system ( p <0.05). Tukey's HSD multiple comparisons indicated that the zirconia restoration fabricated from either CS3500 or Trios-3 demonstrated a significantly larger marginal gap than the conventional cast metal restoration ( p <0.05). Full-arch zirconia restoration fabricated from the Trios-3 illustrated better marginal fits than that from the CS3500, although, both were slightly less accurate than the conventional cast restoration. However, the marginal discrepancies of restoration produced by both CAD-CAM systems were within the clinically acceptable range and satisfactorily precise to be suggested for construction full-arch zirconia restoration.
Marginal Accuracy and Internal Fit of 3-D Printing Laser-Sintered Co-Cr Alloy Copings.
Kim, Myung-Joo; Choi, Yun-Jung; Kim, Seong-Kyun; Heo, Seong-Joo; Koak, Jai-Young
2017-01-23
Laser sintered technology has been introduced for clinical use and can be utilized more widely, accompanied by the digitalization of dentistry and the development of direct oral scanning devices. This study was performed with the aim of comparing the marginal accuracy and internal fit of Co-Cr alloy copings fabricated by casting, CAD/CAM (Computer-aided design/Computer-assisted manufacture) milled, and 3-D laser sintered techniques. A total of 36 Co-Cr alloy crown-copings were fabricated from an implant abutment. The marginal and internal fit were evaluated by measuring the weight of the silicone material, the vertical marginal discrepancy using a microscope, and the internal gap in the sectioned specimens. The data were statistically analyzed by One-way ANOVA (analysis of variance), a Scheffe's test, and Pearson's correlation at the significance level of p = 0.05, using statistics software. The silicone weight was significantly low in the casting group. The 3-D laser sintered group showed the highest vertical discrepancy, and marginal-, occlusal-, and average- internal gaps ( p < 0.05). The CAD/CAM milled group revealed a significantly high axial internal gap. There are moderate correlations between the vertical marginal discrepancy and the internal gap variables ( r = 0.654), except for the silicone weight. In this study, the 3-D laser sintered group achieved clinically acceptable marginal accuracy and internal fit.
Marginal Accuracy and Internal Fit of 3-D Printing Laser-Sintered Co-Cr Alloy Copings
Kim, Myung-Joo; Choi, Yun-Jung; Kim, Seong-Kyun; Heo, Seong-Joo; Koak, Jai-Young
2017-01-01
Laser sintered technology has been introduced for clinical use and can be utilized more widely, accompanied by the digitalization of dentistry and the development of direct oral scanning devices. This study was performed with the aim of comparing the marginal accuracy and internal fit of Co-Cr alloy copings fabricated by casting, CAD/CAM (Computer-aided design/Computer-assisted manufacture) milled, and 3-D laser sintered techniques. A total of 36 Co-Cr alloy crown-copings were fabricated from an implant abutment. The marginal and internal fit were evaluated by measuring the weight of the silicone material, the vertical marginal discrepancy using a microscope, and the internal gap in the sectioned specimens. The data were statistically analyzed by One-way ANOVA (analysis of variance), a Scheffe’s test, and Pearson’s correlation at the significance level of p = 0.05, using statistics software. The silicone weight was significantly low in the casting group. The 3-D laser sintered group showed the highest vertical discrepancy, and marginal-, occlusal-, and average- internal gaps (p < 0.05). The CAD/CAM milled group revealed a significantly high axial internal gap. There are moderate correlations between the vertical marginal discrepancy and the internal gap variables (r = 0.654), except for the silicone weight. In this study, the 3-D laser sintered group achieved clinically acceptable marginal accuracy and internal fit. PMID:28772451
SIRTF Focal Plane Survey: A Pre-flight Error Analysis
NASA Technical Reports Server (NTRS)
Bayard, David S.; Brugarolas, Paul B.; Boussalis, Dhemetrios; Kang, Bryan H.
2003-01-01
This report contains a pre-flight error analysis of the calibration accuracies expected from implementing the currently planned SIRTF focal plane survey strategy. The main purpose of this study is to verify that the planned strategy will meet focal plane survey calibration requirements (as put forth in the SIRTF IOC-SV Mission Plan [4]), and to quantify the actual accuracies expected. The error analysis was performed by running the Instrument Pointing Frame (IPF) Kalman filter on a complete set of simulated IOC-SV survey data, and studying the resulting propagated covariances. The main conclusion of this study is that the all focal plane calibration requirements can be met with the currently planned survey strategy. The associated margins range from 3 to 95 percent, and tend to be smallest for frames having a 0.14" requirement, and largest for frames having a more generous 0.28" (or larger) requirement. The smallest margin of 3 percent is associated with the IRAC 3.6 and 5.8 micron array centers (frames 068 and 069), and the largest margin of 95 percent is associated with the MIPS 160 micron array center (frame 087). For pointing purposes, the most critical calibrations are for the IRS Peakup sweet spots and short wavelength slit centers (frames 019, 023, 052, 028, 034). Results show that these frames are meeting their 0.14" requirements with an expected accuracy of approximately 0.1", which corresponds to a 28 percent margin.
Effect of various putty-wash impression techniques on marginal fit of cast crowns.
Nissan, Joseph; Rosner, Ofir; Bukhari, Mohammed Amin; Ghelfan, Oded; Pilo, Raphael
2013-01-01
Marginal fit is an important clinical factor that affects restoration longevity. The accuracy of three polyvinyl siloxane putty-wash impression techniques was compared by marginal fit assessment using the nondestructive method. A stainless steel master cast containing three abutments with three metal crowns matching the three preparations was used to make 45 impressions: group A = single-step technique (putty and wash impression materials used simultaneously), group B = two-step technique with a 2-mm relief (putty as a preliminary impression to create a 2-mm wash space followed by the wash stage), and group C = two-step technique with a polyethylene spacer (plastic spacer used with the putty impression followed by the wash stage). Accuracy was assessed using a toolmaker microscope to measure and compare the marginal gaps between each crown and finish line on the duplicated stone casts. Each abutment was further measured at the mesial, buccal, and distal aspects. One-way analysis of variance was used for statistical analysis. P values and Scheffe post hoc contrasts were calculated. Significance was determined at .05. One-way analysis of variance showed significant differences among the three impression techniques in all three abutments and at all three locations (P < .001). Group B yielded dies with minimal gaps compared to groups A and C. The two-step impression technique with 2-mm relief was the most accurate regarding the crucial clinical factor of marginal fit.
Sirisathit, Issarawas
2018-01-01
Objective This study evaluated marginal accuracy of full-arch zirconia restoration fabricated from two digital computer-aided design and computer-aided manufacturing (CAD-CAM) systems (Trios-3 and CS3500) in comparison to conventional cast metal restoration. Materials and methods A stainless steel model comprising two canine and two molar abutments was used as a master model for full-arch reconstruction. The canine and molar abutments were machined in a cylindrical shape with 5° taper and chamfer margin. The CAD-CAM systems based on the digital approach were used to construct the full-arch zirconia restoration. The conventional cast metal restoration was fabricated according to a conventional lost-wax technique using nickel–chromium alloys. Ten restorations were fabricated from each system. The marginal accuracy of each restoration was determined at four locations for each abutment. An analysis of variance (ANOVA) and Tukey’s honest significant difference (HSD) multiple comparisons were used to determine statistically significant difference at 95% confidence interval. Results The mean values of marginal accuracy of restorations fabricated from conventional casting, Trios-3, and CS3500 were 48.59±4.16 μm, 53.50±5.66 μm, and 56.47±5.52 μm, respectively. ANOVA indicated significant difference in marginal fit of restorations among various systems. The marginal discrepancy of zirconia restoration fabricated from the CS3500 system demonstrated significantly larger gap than that fabricated from the 3Shape system (p<0.05). Tukey’s HSD multiple comparisons indicated that the zirconia restoration fabricated from either CS3500 or Trios-3 demonstrated a significantly larger marginal gap than the conventional cast metal restoration (p<0.05). Conclusion Full-arch zirconia restoration fabricated from the Trios-3 illustrated better marginal fits than that from the CS3500, although, both were slightly less accurate than the conventional cast restoration. However, the marginal discrepancies of restoration produced by both CAD-CAM systems were within the clinically acceptable range and satisfactorily precise to be suggested for construction full-arch zirconia restoration. PMID:29497334
Read margin analysis of crossbar arrays using the cell-variability-aware simulation method
NASA Astrophysics Data System (ADS)
Sun, Wookyung; Choi, Sujin; Shin, Hyungsoon
2018-02-01
This paper proposes a new concept of read margin analysis of crossbar arrays using cell-variability-aware simulation. The size of the crossbar array should be considered to predict the read margin characteristic of the crossbar array because the read margin depends on the number of word lines and bit lines. However, an excessively high-CPU time is required to simulate large arrays using a commercial circuit simulator. A variability-aware MATLAB simulator that considers independent variability sources is developed to analyze the characteristics of the read margin according to the array size. The developed MATLAB simulator provides an effective method for reducing the simulation time while maintaining the accuracy of the read margin estimation in the crossbar array. The simulation is also highly efficient in analyzing the characteristic of the crossbar memory array considering the statistical variations in the cell characteristics.
Quantifying Safety Margin Using the Risk-Informed Safety Margin Characterization (RISMC)
DOE Office of Scientific and Technical Information (OSTI.GOV)
Grabaskas, David; Bucknor, Matthew; Brunett, Acacia
2015-04-26
The Risk-Informed Safety Margin Characterization (RISMC), developed by Idaho National Laboratory as part of the Light-Water Reactor Sustainability Project, utilizes a probabilistic safety margin comparison between a load and capacity distribution, rather than a deterministic comparison between two values, as is usually done in best-estimate plus uncertainty analyses. The goal is to determine the failure probability, or in other words, the probability of the system load equaling or exceeding the system capacity. While this method has been used in pilot studies, there has been little work conducted investigating the statistical significance of the resulting failure probability. In particular, it ismore » difficult to determine how many simulations are necessary to properly characterize the failure probability. This work uses classical (frequentist) statistics and confidence intervals to examine the impact in statistical accuracy when the number of simulations is varied. Two methods are proposed to establish confidence intervals related to the failure probability established using a RISMC analysis. The confidence interval provides information about the statistical accuracy of the method utilized to explore the uncertainty space, and offers a quantitative method to gauge the increase in statistical accuracy due to performing additional simulations.« less
Memon, S; Lynch, A C; Bressel, M; Wise, A G; Heriot, A G
2015-09-01
Restaging imaging by MRI or endorectal ultrasound (ERUS) following neoadjuvant chemoradiotherapy is not routinely performed, but the assessment of response is becoming increasingly important to facilitate individualization of management. A search of the MEDLINE and Scopus databases was performed for studies that evaluated the accuracy of restaging of rectal cancer following neoadjuvant chemoradiotherapy with MRI or ERUS against the histopathological outcome. A systematic review of selected studies was performed. The methodological quality of studies that qualified for meta-analysis was critically assessed to identify studies suitable for inclusion in the meta-analysis. Sixty-three articles were included in the systematic review. Twelve restaging MRI studies and 18 restaging ERUS studies were eligible for meta-analysis of T-stage restaging accuracy. Overall, ERUS T-stage restaging accuracy (mean [95% CI]: 65% [56-72%]) was nonsignificantly higher than MRI T-stage accuracy (52% [44-59%]). Restaging MRI is accurate at excluding circumferential resection margin involvement. Restaging MRI and ERUS were equivalent for prediction of nodal status: the accuracy of both investigations was 72% with over-staging and under-staging occurring in 10-15%. The heterogeneity amongst restaging studies is high, limiting conclusive findings regarding their accuracies. The accuracy of restaging imaging is different for different pathological T stages and highest for T3 tumours. Morphological assessment of T- or N-stage by MRI or ERUS is currently not accurate or consistent enough for clinical application. Restaging MRI appears to have a role in excluding circumferential resection margin involvement. Colorectal Disease © 2015 The Association of Coloproctology of Great Britain and Ireland.
Reddy, S Srikanth; Revathi, Kakkirala; Reddy, S Kranthikumar
2013-01-01
Conventional casting technique is time consuming when compared to accelerated casting technique. In this study, marginal accuracy of castings fabricated using accelerated and conventional casting technique was compared. 20 wax patterns were fabricated and the marginal discrepancy between the die and patterns were measured using Optical stereomicroscope. Ten wax patterns were used for Conventional casting and the rest for Accelerated casting. A Nickel-Chromium alloy was used for the casting. The castings were measured for marginal discrepancies and compared. Castings fabricated using Conventional casting technique showed less vertical marginal discrepancy than the castings fabricated by Accelerated casting technique. The values were statistically highly significant. Conventional casting technique produced better marginal accuracy when compared to Accelerated casting. The vertical marginal discrepancy produced by the Accelerated casting technique was well within the maximum clinical tolerance limits. Accelerated casting technique can be used to save lab time to fabricate clinical crowns with acceptable vertical marginal discrepancy.
Vila, Peter M; Park, Chan W; Pierce, Mark C; Goldstein, Gregg H; Levy, Lauren; Gurudutt, Vivek V; Polydorides, Alexandros D; Godbold, James H; Teng, Marita S; Genden, Eric M; Miles, Brett A; Anandasabapathy, Sharmila; Gillenwater, Ann M; Richards-Kortum, Rebecca; Sikora, Andrew G
2012-10-01
The efficacy of ablative surgery for head and neck squamous cell carcinoma (HNSCC) depends critically on obtaining negative margins. Although intraoperative "frozen section" analysis of margins is a valuable adjunct, it is expensive, time-consuming, and highly dependent on pathologist expertise. Optical imaging has potential to improve the accuracy of margins by identifying cancerous tissue in real time. Our goal was to determine the accuracy and inter-rater reliability of head and neck cancer specialists using high-resolution microendoscopic (HRME) images to discriminate between cancerous and benign mucosa. Thirty-eight patients diagnosed with head and neck squamous cell carcinoma (HNSCC) were enrolled in this single-center study. HRME was used to image each specimen after application of proflavine, with concurrent standard histopathologic analysis. Images were evaluated for quality control, and a training set containing representative images of benign and neoplastic tissue was assembled. After viewing training images, seven head and neck cancer specialists with no previous HRME experience reviewed 36 test images and were asked to classify each. The mean accuracy of all reviewers in correctly diagnosing neoplastic mucosa was 97% (95% confidence interval (CI), 94-99%). The mean sensitivity and specificity were 98% (97-100%) and 92% (87-98%), respectively. The Fleiss kappa statistic for inter-rater reliability was 0.84 (0.77-0.91). Medical professionals can be quickly trained to use HRME to discriminate between benign and neoplastic mucosa in the head and neck. With further development, the HRME shows promise as a method of real-time margin determination at the point of care.
Vila, Peter M.; Park, Chan W.; Pierce, Mark C.; Goldstein, Gregg H.; Levy, Lauren; Gurudutt, Vivek V.; Polydorides, Alexandras D.; Godbold, James H.; Teng, Marita S.; Genden, Eric M.; Miles, Brett A.; Anandasabapathy, Sharmila; Gillenwater, Ann M.; Richards-Kortum, Rebecca; Sikora, Andrew G.
2012-01-01
Background The efficacy of ablative surgery for head and neck squamous cell carcinoma (HNSCC) depends critically on obtaining negative margins. While intraoperative "frozen section" analysis of margins is a valuable adjunct, it is expensive, time-consuming, and highly dependent on pathologist expertise. Optical imaging has potential to improve the accuracy of margins by identifying cancerous tissue in real time. Our aim was to determine the accuracy and inter-rater reliability of head and neck cancer specialists using high-resolution microendoscopic (HRME) images to discriminate between cancerous and benign mucosa. Methods Thirty-eight patients diagnosed with HNSCC were enrolled in this single-center study. HRME was used to image each specimen after application of proflavine, with concurrent standard histopathologic analysis. Images were evaluated for quality control, and a training set containing representative images of benign and neoplastic tissue was assembled. After viewing training images, seven head and neck cancer specialists with no prior HRME experience reviewed 37 test images and were asked to classify each. Results The mean accuracy of all reviewers in correctly diagnosing neoplastic mucosa was 97 percent (95% Cl = 94–99%). The mean sensitivity and specificity were 98 percent (97–100%) and 92 percent (87–98%), respectively. The Fleiss kappa statistic for inter-rater reliability was 0.84 (0.77–0.91). Conclusions Medical professionals can be quickly trained to use HRME to discriminate between benign and neoplastic mucosa in the head and neck. With further development, the HRME shows promise as a method of real-time margin determination at the point of care. PMID:22492225
Product Quality Modelling Based on Incremental Support Vector Machine
NASA Astrophysics Data System (ADS)
Wang, J.; Zhang, W.; Qin, B.; Shi, W.
2012-05-01
Incremental Support vector machine (ISVM) is a new learning method developed in recent years based on the foundations of statistical learning theory. It is suitable for the problem of sequentially arriving field data and has been widely used for product quality prediction and production process optimization. However, the traditional ISVM learning does not consider the quality of the incremental data which may contain noise and redundant data; it will affect the learning speed and accuracy to a great extent. In order to improve SVM training speed and accuracy, a modified incremental support vector machine (MISVM) is proposed in this paper. Firstly, the margin vectors are extracted according to the Karush-Kuhn-Tucker (KKT) condition; then the distance from the margin vectors to the final decision hyperplane is calculated to evaluate the importance of margin vectors, where the margin vectors are removed while their distance exceed the specified value; finally, the original SVs and remaining margin vectors are used to update the SVM. The proposed MISVM can not only eliminate the unimportant samples such as noise samples, but also can preserve the important samples. The MISVM has been experimented on two public data and one field data of zinc coating weight in strip hot-dip galvanizing, and the results shows that the proposed method can improve the prediction accuracy and the training speed effectively. Furthermore, it can provide the necessary decision supports and analysis tools for auto control of product quality, and also can extend to other process industries, such as chemical process and manufacturing process.
Jianming, Yuan; Ying, Tang; Feng, Pan; Weixing, Xu
2016-12-01
This study aims to compare the marginal accuracy of single crowns fabricated using self-curing resin, Luxatemp, and computer aided design/computer aided manufacturing (CAD/CAM) methods in clinical application. A total of 30 working dies, which were obtained from 30 clinical teeth prepared with full crown as standard, were created and made into 30 self-curing resin, Luxatemp, and CAD/CAM single crowns. The restorations were seated on the working dies, and stereomicroscope was used to observe and measure the thickness of reference points. One-way analysis of variance, which was performed using SPSS 19.0 software package, compared the marginal gap widths of self-curing resin, Luxatemp, and CAD/CAM provisional crowns. The mean marginal gap widths of the fabricated self-curing resin, Luxatemp, and CAD/CAM were (179.06±33.24), (88.83±9.56), and (43.61±7.27) μm, respectively. A significant difference was observed among the three provisional crowns (P<0.05). The marginal gap width of CAD/CAM provisional crown was lower than that of the self-curing resin and Luxatemp. Thus, the CAD/CAM provisional crown offers a better remediation effect in clinical application.
Isotani, Shuji; Shimoyama, Hirofumi; Yokota, Isao; China, Toshiyuki; Hisasue, Shin-ichi; Ide, Hisamitsu; Muto, Satoru; Yamaguchi, Raizo; Ukimura, Osamu; Horie, Shigeo
2015-05-01
To evaluate the feasibility and accuracy of virtual partial nephrectomy analysis, including a color-coded three-dimensional virtual surgical planning and a quantitative functional analysis, in predicting the surgical outcomes of robot-assisted partial nephrectomy. Between 2012 and 2014, 20 patients underwent virtual partial nephrectomy analysis before undergoing robot-assisted partial nephrectomy. Virtual partial nephrectomy analysis was carried out with the following steps: (i) evaluation of the arterial branch for selective clamping by showing the vascular-supplied area; (ii) simulation of the optimal surgical margin in precise segmented three-dimensional model for prediction of collecting system opening; and (iii) detailed volumetric analyses and estimates of postoperative renal function based on volumetric change. At operation, the surgeon identified the targeted artery and determined the surgical margin according to the virtual partial nephrectomy analysis. The surgical outcomes between the virtual partial nephrectomy analysis and the actual robot-assisted partial nephrectomy were compared. All 20 patients had negative cancer surgical margins and no urological complications. The tumor-specific renal arterial supply areas were shown in color-coded three-dimensional model visualization in all cases. The prediction value of collecting system opening was 85.7% for sensitivity and 100% for specificity. The predicted renal resection volume was significantly correlated with actual resected specimen volume (r(2) = 0.745, P < 0.001). The predicted estimated glomerular filtration rate was significantly correlated with actual postoperative estimated glomerular filtration rate (r(2) = 0.736, P < 0.001). Virtual partial nephrectomy analysis is able to provide the identification of tumor-specific renal arterial supply, prediction of collecting system opening and prediction of postoperative renal function. This technique might allow urologists to compare various arterial clamping methods and resection margins with surgical outcomes in a non-invasive manner. © 2015 The Japanese Urological Association.
Meta-analysis of studies with bivariate binary outcomes: a marginal beta-binomial model approach
Chen, Yong; Hong, Chuan; Ning, Yang; Su, Xiao
2018-01-01
When conducting a meta-analysis of studies with bivariate binary outcomes, challenges arise when the within-study correlation and between-study heterogeneity should be taken into account. In this paper, we propose a marginal beta-binomial model for the meta-analysis of studies with binary outcomes. This model is based on the composite likelihood approach, and has several attractive features compared to the existing models such as bivariate generalized linear mixed model (Chu and Cole, 2006) and Sarmanov beta-binomial model (Chen et al., 2012). The advantages of the proposed marginal model include modeling the probabilities in the original scale, not requiring any transformation of probabilities or any link function, having closed-form expression of likelihood function, and no constraints on the correlation parameter. More importantly, since the marginal beta-binomial model is only based on the marginal distributions, it does not suffer from potential misspecification of the joint distribution of bivariate study-specific probabilities. Such misspecification is difficult to detect and can lead to biased inference using currents methods. We compare the performance of the marginal beta-binomial model with the bivariate generalized linear mixed model and the Sarmanov beta-binomial model by simulation studies. Interestingly, the results show that the marginal beta-binomial model performs better than the Sarmanov beta-binomial model, whether or not the true model is Sarmanov beta-binomial, and the marginal beta-binomial model is more robust than the bivariate generalized linear mixed model under model misspecifications. Two meta-analyses of diagnostic accuracy studies and a meta-analysis of case-control studies are conducted for illustration. PMID:26303591
Grit blasting and the marginal accuracy of two ceramic veneer systems--a pilot study.
Lim, C; Ironside, J G
1997-04-01
Margins of ceramic restorations can be damaged during removal of investment materials with grit blasting and result in relatively large marginal discrepancies and excessive marginal discrepancies with greater exposure of cement to the oral environment. Subsequent dissolution of cement can encourage plaque retention, dental caries, and periodontal problems. This study compared marginal adaptation of ceramic veneers created by the refractory die technique (R), Dicor glass ceramic technique (D), and effects of grit blasting on their margins. Two groups of ceramic veneers were constructed for each system, one without grit blasting (R g and D g) and one with grit blasting (R+g and D+g). Statistical analyses revealed that grit blasting had a greater effect in reducing marginal accuracy for Dicor ceramic veneers compared with refractory die ceramic veneers.
Vojdani, Mahroo; Torabi, Kianoosh; Atashkar, Berivan; Heidari, Hossein; Torabi Ardakani, Mahshid
2016-12-01
Marginal fitness is the most important criteria for evaluation of the clinical acceptability of a cast restoration. Marginal gap which is due to cement solubility and plaque retention is potentially detrimental to both tooth and periodontal tissues. This in vitro study aimed to evaluate the marginal and internal fit of cobalt- chromium (Co-Cr) copings fabricated by two different CAD/CAM systems: (CAD/ milling and CAD/ Ceramill Sintron). We prepared one machined standard stainless steel master model with following dimensions: 7 mm height, 5mm diameter, 90˚ shoulder marginal finish line with 1 mm width, 10˚ convergence angle and anti-rotational surface on the buccal aspect of the die. There were 10 copings produced from hard presintered Co-Cr blocks according to CAD/ Milling technique and ten copings from soft non- presintered Co-Cr blocks according to CAD/ Ceramill Sintron technique. Marginal and internal accuracies of copings were documented by the replica technique. Replicas were examined at ten reference points under a digital microscope (230X). The Student's t-test was used for statistical analysis. p < 0.001 was considered significant. Statistically significant differences existed between the groups ( p < 0.001). The CAD/milling group (hard copings) had a mean marginal discrepancy (MD) of 104 µm, axial discrepancy (AD) of 23 µm and occlusal discrepancy of 130 µm. For CAD/ Ceramill Sintron group, these values were 195 µm (MD), 46 µm (AD), and 232 µm (OD). Internal total discrepancy (ITD) for the CAD/milling group was 77 µm, whereas for the CAD/Ceramill Sintron group was 143 µm. Hard presintered Co-Cr copings had significantly higher marginal and internal accuracies compared to the soft non-presintered copings.
Hayashi, Masamichi; Guerrero-Preston, Rafael; Sidransky, David; Koch, Wayne M.
2015-01-01
Molecular deep surgical margin analysis has been shown to predict locoregional recurrences of head and neck squamous cell carcinoma (HNSCC). In order to improve the accuracy and versatility of the analysis, we used a highly tumor-specific methylation marker and highly sensitive detection technology to test DNA from surgical margins. Histologically cancer-negative deep surgical margin samples were prospectively collected from 82 eligible HNSCC surgeries by an imprinting procedure (n=75) and primary tissue collection (n=70). Bisulfite treated DNA from each sample was analyzed by both conventional quantitative methylation-specific polymerase chain reaction (QMSP) and QMSP by droplet digital PCR (ddQMSP) targeting PAX5 gene promoter methylation. The association between the presence of PAX5 methylation and locoregional recurrence free survival (LRFS) was evaluated. PAX5 methylation was found in 68.0% (51/75) of tumors in the imprint samples and 71.4% (50/70) in the primary tissue samples. Among cases which did not have postoperative radiation, (n=31 in imprint samples, n=29 in tissue samples), both conventional QMSP and ddQMSP revealed that PAX5 methylation positive margins was significantly associated with poor LRFS by univariate analysis. In particular, ddQMSP increased detection of the PAX5 marker from 29% to 71% in the non-radiated imprint cases. Also, PAX5 methylated imprint margins were an excellent predictor of poor LRFS (HR=3.89, 95%CI:1.19-17.52, P=0.023) by multivariate analysis. PAX5 methylation appears to be an excellent tumor-specific marker for molecular deep surgical margin analysis of HNSCC. Moreover, the ddQMSP assay displays increased sensitivity for methylation marker detection. PMID:26304463
Accuracy of the One-Stage and Two-Stage Impression Techniques: A Comparative Analysis
Jamshidy, Ladan; Faraji, Payam; Sharifi, Roohollah
2016-01-01
Introduction. One of the main steps of impression is the selection and preparation of an appropriate tray. Hence, the present study aimed to analyze and compare the accuracy of one- and two-stage impression techniques. Materials and Methods. A resin laboratory-made model, as the first molar, was prepared by standard method for full crowns with processed preparation finish line of 1 mm depth and convergence angle of 3-4°. Impression was made 20 times with one-stage technique and 20 times with two-stage technique using an appropriate tray. To measure the marginal gap, the distance between the restoration margin and preparation finish line of plaster dies was vertically determined in mid mesial, distal, buccal, and lingual (MDBL) regions by a stereomicroscope using a standard method. Results. The results of independent test showed that the mean value of the marginal gap obtained by one-stage impression technique was higher than that of two-stage impression technique. Further, there was no significant difference between one- and two-stage impression techniques in mid buccal region, but a significant difference was reported between the two impression techniques in MDL regions and in general. Conclusion. The findings of the present study indicated higher accuracy for two-stage impression technique than for the one-stage impression technique. PMID:28003824
Accuracy of the One-Stage and Two-Stage Impression Techniques: A Comparative Analysis.
Jamshidy, Ladan; Mozaffari, Hamid Reza; Faraji, Payam; Sharifi, Roohollah
2016-01-01
Introduction . One of the main steps of impression is the selection and preparation of an appropriate tray. Hence, the present study aimed to analyze and compare the accuracy of one- and two-stage impression techniques. Materials and Methods . A resin laboratory-made model, as the first molar, was prepared by standard method for full crowns with processed preparation finish line of 1 mm depth and convergence angle of 3-4°. Impression was made 20 times with one-stage technique and 20 times with two-stage technique using an appropriate tray. To measure the marginal gap, the distance between the restoration margin and preparation finish line of plaster dies was vertically determined in mid mesial, distal, buccal, and lingual (MDBL) regions by a stereomicroscope using a standard method. Results . The results of independent test showed that the mean value of the marginal gap obtained by one-stage impression technique was higher than that of two-stage impression technique. Further, there was no significant difference between one- and two-stage impression techniques in mid buccal region, but a significant difference was reported between the two impression techniques in MDL regions and in general. Conclusion . The findings of the present study indicated higher accuracy for two-stage impression technique than for the one-stage impression technique.
Haralur, Satheesh B; Hamdi, Osama A; Al-Shahrani, Abdulaziz A; Alhasaniah, Sultan
2017-01-01
To evaluate the effect of varying cellulose casting ring liner length and its prewetting on the marginal adaptation and dimensional accuracy of full veneer metal castings. The master die was milled in stainless steel to fabricate the wax pattern. Sixty wax patterns were fabricated with a uniform thickness of 1.5 mm at an occlusal surface and 1 mm axial surface, cervical width at 13.5 mm, and 10 mm cuspal height. The samples were divided into six groups ( n = 10). Groups I and II samples had the full-length cellulose prewet and dry ring liner, respectively. The groups III and IV had 2 mm short prewet and dry cellulose ring liner, respectively, whereas groups V and VI were invested in 6 mm short ring liner. The wax patterns were immediately invested in phosphate bonded investment, and casting procedure was completed with nickel-chrome alloy. The castings were cleaned and mean score of measurements at four reference points for marginal adaption, casting height, and cervical width was calculated. The marginal adaption was calculated with Imaje J software, whereas the casting height and cervical width was determined using a digital scale. The data was subjected to one-way analysis of varaince and Tukey post hoc statistical analysis with Statistical Package for the Social Sciences version 20 software. The group II had the best marginal adaption with a gap of 63.786 μm followed by group I (65.185 μm), group IV (87.740 μm), and group III (101.455 μm). A large marginal gap was observed in group V at 188.871 μm. Cuspal height was more accurate with group V (10.428 mm), group VI (10.421 mm), and group II (10.488 mm). The cervical width was approximately similar in group I, group III, and group V. Statistically significant difference was observed in Tukey post hoc analysis between group V and group VI with all the other groups with regards to marginal adaptation. The dry cellulose ring liners provided better marginal adaptation in comparison to prewet cellulose ring liners. Accurate cuspal height was obtained with shorter ring liner in comparison to full-length cellulose ring liners.
Haralur, Satheesh B.; Hamdi, Osama A.; Al-Shahrani, Abdulaziz A.; Alhasaniah, Sultan
2017-01-01
Aim: To evaluate the effect of varying cellulose casting ring liner length and its prewetting on the marginal adaptation and dimensional accuracy of full veneer metal castings. Materials and Methods: The master die was milled in stainless steel to fabricate the wax pattern. Sixty wax patterns were fabricated with a uniform thickness of 1.5 mm at an occlusal surface and 1 mm axial surface, cervical width at 13.5 mm, and 10 mm cuspal height. The samples were divided into six groups (n = 10). Groups I and II samples had the full-length cellulose prewet and dry ring liner, respectively. The groups III and IV had 2 mm short prewet and dry cellulose ring liner, respectively, whereas groups V and VI were invested in 6 mm short ring liner. The wax patterns were immediately invested in phosphate bonded investment, and casting procedure was completed with nickel-chrome alloy. The castings were cleaned and mean score of measurements at four reference points for marginal adaption, casting height, and cervical width was calculated. The marginal adaption was calculated with Imaje J software, whereas the casting height and cervical width was determined using a digital scale. The data was subjected to one-way analysis of varaince and Tukey post hoc statistical analysis with Statistical Package for the Social Sciences version 20 software. Results: The group II had the best marginal adaption with a gap of 63.786 μm followed by group I (65.185 μm), group IV (87.740 μm), and group III (101.455 μm). A large marginal gap was observed in group V at 188.871 μm. Cuspal height was more accurate with group V (10.428 mm), group VI (10.421 mm), and group II (10.488 mm). The cervical width was approximately similar in group I, group III, and group V. Statistically significant difference was observed in Tukey post hoc analysis between group V and group VI with all the other groups with regards to marginal adaptation. Conclusion: The dry cellulose ring liners provided better marginal adaptation in comparison to prewet cellulose ring liners. Accurate cuspal height was obtained with shorter ring liner in comparison to full-length cellulose ring liners. PMID:28316950
Kim, Kyung Hwan; Park, Min Jung; Lim, Joon Seok; Kim, Nam Kyu; Min, Byung Soh; Ahn, Joong Bae; Kim, Tae Il; Kim, Ho Geun; Koom, Woong Sub
2016-04-01
To identify patients who are at a higher risk of pathologic circumferential resection margin involvement using preoperative magnetic resonance imaging. Between October 2008 and November 2012, 165 patients with locally advanced rectal cancer (cT4 or cT3 with <2 mm distance from tumour to mesorectal fascia) who received preoperative chemoradiotherapy were analysed. The morphologic patterns on post-chemoradiotherapy magnetic resonance imaging were categorized into five patterns from Pattern A (most-likely negative pathologic circumferential resection margin) to Pattern E (most-likely positive pathologic circumferential resection margin). In addition, the location of mesorectal fascia involvement was classified as lateral, posterior and anterior. The diagnostic accuracy of the morphologic criteria was calculated using receiver operating characteristic curve analysis. Pathologic circumferential resection margin involvement was identified in 17 patients (10.3%). The diagnostic accuracy of predicting pathologic circumferential resection margin involvement was 0.73 using the five-scale magnetic resonance imaging pattern. The sensitivity, specificity, positive predictive value and negative predictive value for predicting pathologic circumferential resection margin involvement were 76.5, 65.5, 20.3 and 96.0%, respectively, when cut-off was set between Patterns C and D. On multivariate logistic regression, the magnetic resonance imaging patterns D and E (P= 0.005) and posterior or lateral mesorectal fascia involvement (P= 0.017) were independently associated with increased probability of pathologic circumferential resection margin involvement. The rate of pathologic circumferential resection margin involvement was 30.0% when the patient had Pattern D or E with posterior or lateral mesorectal fascia involvement. Patients who are at a higher risk of pathologic circumferential resection margin involvement can be identified using preoperative magnetic resonance imaging although the predictability is moderate. © The Author 2016. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.
Nelson, Neha; K S, Jyothi; Sunny, Kiran
2017-03-01
The margins of copings for crowns and retainers of fixed partial dentures affect the progress of microleakage and dental caries. Failures occur due to altered fit which is also influenced by the method of fabrication. An in-vitro study was conducted to determine among the cast base metal, copy milled zirconia, computer aided designing computer aided machining/manufacturing zirconia and direct metal laser sintered copings which showed best marginal accuracy and internal fit. Forty extracted maxillary premolars were mounted on an acrylic model and reduced occlusally using a milling machine up to a final tooth height of 4 mm from the cementoenamel junction. Axial reduction was accomplished on a surveyor and a chamfer finish line was given. The impressions and dies were made for fabrication of copings which were luted on the prepared teeth under standardized loading, embedded in self-cure acrylic resin, sectioned and observed using scanning electron microscope for internal gap and marginal accuracy. The copings fabricated using direct metal laser sintering technique exhibited best marginal accuracy and internal fit. Comparison of mean between the four groups by ANOVA and post-hoc Tukey HSD tests showed a statistically significant difference between all the groups (p⟨0.05). It was concluded that the copings fabricated using direct metal laser sintering technique exhibited best marginal accuracy and internal fit. Additive digital technologies such as direct metal laser sintering could be cost-effective for the clinician, minimize failures related to fit and increase longevity of teeth and prostheses. Copyright© 2017 Dennis Barber Ltd.
Meta-analysis of studies with bivariate binary outcomes: a marginal beta-binomial model approach.
Chen, Yong; Hong, Chuan; Ning, Yang; Su, Xiao
2016-01-15
When conducting a meta-analysis of studies with bivariate binary outcomes, challenges arise when the within-study correlation and between-study heterogeneity should be taken into account. In this paper, we propose a marginal beta-binomial model for the meta-analysis of studies with binary outcomes. This model is based on the composite likelihood approach and has several attractive features compared with the existing models such as bivariate generalized linear mixed model (Chu and Cole, 2006) and Sarmanov beta-binomial model (Chen et al., 2012). The advantages of the proposed marginal model include modeling the probabilities in the original scale, not requiring any transformation of probabilities or any link function, having closed-form expression of likelihood function, and no constraints on the correlation parameter. More importantly, because the marginal beta-binomial model is only based on the marginal distributions, it does not suffer from potential misspecification of the joint distribution of bivariate study-specific probabilities. Such misspecification is difficult to detect and can lead to biased inference using currents methods. We compare the performance of the marginal beta-binomial model with the bivariate generalized linear mixed model and the Sarmanov beta-binomial model by simulation studies. Interestingly, the results show that the marginal beta-binomial model performs better than the Sarmanov beta-binomial model, whether or not the true model is Sarmanov beta-binomial, and the marginal beta-binomial model is more robust than the bivariate generalized linear mixed model under model misspecifications. Two meta-analyses of diagnostic accuracy studies and a meta-analysis of case-control studies are conducted for illustration. Copyright © 2015 John Wiley & Sons, Ltd.
The new analysis method of PWQ in the DRAM pattern
NASA Astrophysics Data System (ADS)
Han, Daehan; Chang, Jinman; Kim, Taeheon; Lee, Kyusun; Kim, Yonghyeon; Kang, Jinyoung; Hong, Aeran; Choi, Bumjin; Lee, Joosung; Kim, Hyoung Jun; Lee, Kweonjae; Hong, Hyoungsun; Jin, Gyoyoung
2016-03-01
In a sub 2Xnm node process, the feedback of pattern weak points is more and more significant. Therefore, it is very important to extract the systemic defect in Double Patterning Technology(DPT), however, it is impossible to predict exact systemic defect at the recent photo simulation tool.[1] Therefore, the method of Process Window Qualification (PWQ) is very serious and essential these days. Conventional PWQ methods are die to die image comparison by using an e-beam or bright field machine. Results are evaluated by the person, who reviews the images, in some cases. However, conventional die to die comparison method has critical problem. If reference die and comparison die have same problem, such as both of dies have pattern problems, the issue patterns are not detected by current defect detecting approach. Aside from the inspection accuracy, reviewing the wafer requires much effort and time to justify the genuine issue patterns. Therefore, our company adopts die to data based matching PWQ method that is using NGR machine. The main features of the NGR are as follows. First, die to data based matching, second High speed, finally massive data were used for evaluation of pattern inspection.[2] Even though our die to data based matching PWQ method measures the mass data, our margin decision process is based on image shape. Therefore, it has some significant problems. First, because of the long analysis time, the developing period of new device is increased. Moreover, because of the limitation of resources, it may not examine the full chip area. Consequently, the result of PWQ weak points cannot represent the all the possible defects. Finally, since the PWQ margin is not decided by the mathematical value, to make the solid definition of killing defect is impossible. To overcome these problems, we introduce a statistical values base process window qualification method that increases the accuracy of process margin and reduces the review time. Therefore, it is possible to see the genuine margin of the critical pattern issue which we cannot see on our conventional PWQ inspection; hence we can enhance the accuracy of PWQ margin.
Moris, Izabela C M; Monteiro, Silas Borges; Martins, Raíssa; Ribeiro, Ricardo Faria; Gomes, Erica A
2018-01-01
To evaluate the influence of different manufacturing methods of single implant-supported metallic crowns on the internal and external marginal fit through computed microtomography. Forty external hexagon implants were divided into 4 groups ( n = 8), according to the manufacturing method: GC, conventional casting; GI, induction casting; GP, plasma casting; and GCAD, CAD/CAM machining. The crowns were attached to the implants with insertion torque of 30 N·cm. The external (vertical and horizontal) marginal fit and internal fit were assessed through computed microtomography. Internal and external marginal fit data ( μ m) were submitted to a one-way ANOVA and Tukey's test ( α = .05). Qualitative evaluation of the images was conducted by using micro-CT. The statistical analysis revealed no significant difference between the groups for vertical misfit ( P = 0.721). There was no significant difference ( P > 0.05) for the internal and horizontal marginal misfit in the groups GC, GI, and GP, but it was found for the group GCAD ( P ≤ 0.05). Qualitative analysis revealed that most of the samples of cast groups exhibited crowns underextension while the group GCAD showed overextension. The manufacturing method of the crowns influenced the accuracy of marginal fit between the prosthesis and implant. The best results were found for the crowns fabricated through CAD/CAM machining.
SU-E-J-188: Theoretical Estimation of Margin Necessary for Markerless Motion Tracking
DOE Office of Scientific and Technical Information (OSTI.GOV)
Patel, R; Block, A; Harkenrider, M
2015-06-15
Purpose: To estimate the margin necessary to adequately cover the target using markerless motion tracking (MMT) of lung lesions given the uncertainty in tracking and the size of the target. Methods: Simulations were developed in Matlab to determine the effect of tumor size and tracking uncertainty on the margin necessary to achieve adequate coverage of the target. For simplicity, the lung tumor was approximated by a circle on a 2D radiograph. The tumor was varied in size from a diameter of 0.1 − 30 mm in increments of 0.1 mm. From our previous studies using dual energy markerless motion tracking,more » we estimated tracking uncertainties in x and y to have a standard deviation of 2 mm. A Gaussian was used to simulate the deviation between the tracked location and true target location. For each size tumor, 100,000 deviations were randomly generated, the margin necessary to achieve at least 95% coverage 95% of the time was recorded. Additional simulations were run for varying uncertainties to demonstrate the effect of the tracking accuracy on the margin size. Results: The simulations showed an inverse relationship between tumor size and margin necessary to achieve 95% coverage 95% of the time using the MMT technique. The margin decreased exponentially with target size. An increase in tracking accuracy expectedly showed a decrease in margin size as well. Conclusion: In our clinic a 5 mm expansion of the internal target volume (ITV) is used to define the planning target volume (PTV). These simulations show that for tracking accuracies in x and y better than 2 mm, the margin required is less than 5 mm. This simple simulation can provide physicians with a guideline estimation for the margin necessary for use of MMT clinically based on the accuracy of their tracking and the size of the tumor.« less
Vaidya, Sharad; Parkash, Hari; Bhargava, Akshay; Gupta, Sharad
2014-01-01
Abundant resources and techniques have been used for complete coverage crown fabrication. Conventional investing and casting procedures for phosphate-bonded investments require a 2- to 4-h procedure before completion. Accelerated casting techniques have been used, but may not result in castings with matching marginal accuracy. The study measured the marginal gap and determined the clinical acceptability of single cast copings invested in a phosphate-bonded investment with the use of conventional and accelerated methods. One hundred and twenty cast coping samples were fabricated using conventional and accelerated methods, with three finish lines: Chamfer, shoulder and shoulder with bevel. Sixty copings were prepared with each technique. Each coping was examined with a stereomicroscope at four predetermined sites and measurements of marginal gaps were documented for each. A master chart was prepared for all the data and was analyzed using Statistical Package for the Social Sciences version. Evidence of marginal gap was then evaluated by t-test. Analysis of variance and Post-hoc analysis were used to compare two groups as well as to make comparisons between three subgroups . Measurements recorded showed no statistically significant difference between conventional and accelerated groups. Among the three marginal designs studied, shoulder with bevel showed the best marginal fit with conventional as well as accelerated casting techniques. Accelerated casting technique could be a vital alternative to the time-consuming conventional casting technique. The marginal fit between the two casting techniques showed no statistical difference.
NASA Astrophysics Data System (ADS)
Souche, A.; Medvedev, S.; Hartz, E. H.
2009-04-01
The sub-ice topography of Greenland is characterized by a central depression below the sea level and by elevated (in some places significantly) margins. Whereas the central depression may be explained by significant load of the Greenland ice sheet, the origin of the peripheral relief remains unclear. We analyze the influence of formation of the ice sheet and carving by glacial erosion on the evolution of topography along the margins of Greenland. Our analysis shows that: (1) The heavy ice loading in the central part of Greenland and consecutive peripheral bulging has a negligible effect on amplitude of the uplifted Greenland margins. (2) First order estimates of uplift due to isostatic readjustment caused by glacial erosion and unloading in the fjord systems is up to 1.1 km. (3) The increase of accuracy of topographic data (comparing several data sets of resolution with grid size from 5 km to 50 m) results in increase of the isostatic response in the model. (4) The analysis of mass redistribution during erosion-sedimentation process and data on age of offshore sediments allows us to estimate the timing of erosion along the margins of Greenland. This ongoing analysis, however, requires careful account for the link between sources (localized glacial erosion) and sinks (offshore sedimentary basins around Greenland).
Analysis of Fractal Parameters of the Lunar Surface
NASA Astrophysics Data System (ADS)
Nefedyev, Yuri; Petrova, Natalia; Andreev, Alexey; Demina, Natalya; Demin, Sergey
2016-07-01
Analysis of complex selenographic systems is a complicatedissue. This fully applies to the lunar topography. In this report a new method of the comparative reliable estimation of thelunar mapsdata is represented. The estimation was made by the comparison of high-altitude lines using the fractal analysis. The influence of the lunar macrofigure variances were determined by the method of fractal dimensions comparison. It should be noted the investigations of the lunar figure and rotation implystudy itsmarginal zone charts constructionwith various methods and this is traditionally carried out at the Engelhardt Astronomical Observatory (EAO). In particular this research is important for lunar occultations reductions and on the basis of that it is possible to solve a number of astrometric and astrophysical problems. By now the highly accurate theories of the lunar movement have been obtained and stars coordinates have been determined on the basis of space measurements with the several multiarcseconds accuracy but there are factors highly influencingon the accuracy of the results of these observations. They are: exactitude of the occultation moment recording, errors of the stars coordinates, accuracy of lunar ephemeris positions and unreliability of lunar marginal zone charts. Therefore difficulties arise during the reduction process of lunar occultations by the reason of irregularities of lunar limb. Existing charts of the lunar marginal zone have some defects. The researching of lunar marginal zone maps is very difficult. First of all, it concernsthe reliability of maps data. To resolve this task thecomparison method in which the structure of the high-altitude lines of data appropriated with identical lunar coordinates can used. However, such comparison requires a lot of calculations. In addition there is a large number of the marginal zone maps constructed by different methods and the accuracy of their data causes many questions. In other words, the lunar relief has a very complex structure and traditional research methods are unacceptable. After considering this, it was decided to use the method of fractal dimensionsd comparisons. For this purpose lunar marginal zone maps made in the celestial coordinate system (maps N1) and oneconstructed on the basis of data obtained from heliometric observations with taking into account thefirst model of the figure of the Moon given by Jakovkin (maps N2) were taken. The charts contain isohypses of the lunar marginal zone extending over 10" on both sides of the mean position of the limb line. In order to find thevariations of irregularities for thelimb points above the mean level of lunar surface werecomputed the position angles of this pointsP (reckoned from the centre of the Moon's disc) and D coordinates. This coordinates introduced by Hayn: P is the selenocentric longitude reckoned along the mean limb from the north pole of the Moon, like the position angles, and D is the latitude counted positively for that part of the disc that is nearer to the observer. Thus the data of our studies was obtained by identical types. Then the first, segments of a lunar marginal zone for every 45" on P were considered. For each segment profile of the surface for a constant D were constructed with a step of 2". Thus 80 profiles were obtained. Secondly the fractal dimensions d for each considered structure was defined. Third the obtained values d werecompared with the othersmaps considered in this work. The obtained results show some well agreement between the mean fractal dimensions for maps N1 and N2. Thus it can be concluded that the using of fractal method for lunar maps analysis to determine the accuracy of the presented to themdata give good results. The work was supported by grants RFBR 15-02-01638-a, 16-32-60071-mol-dk-a and 16-02-00496-a.
Schneider, Lea; Rinke, Sven
2018-01-01
This study evaluated the marginal accuracy of CAD/CAM-fabricated crown copings from four different materials within the same processing route. Twenty stone replicas of a metallic master die (prepared upper premolar) were scanned and divided into two groups. Group 1 (n = 10) was used for a pilot test to determine the design parameters for best marginal accuracy. Group 2 (n = 10) was used to fabricate 10 specimens from the following materials with one identical CAD/CAM system (GAMMA 202, Wissner GmbH, Goettingen, Germany): A = commercially pure (cp) titanium, B = cobalt-chromium alloy, C = yttria-stabilized zirconia (YSZ), and D = leucite-reinforced glass-ceramics. Copings from group 2 were evaluated for the mean marginal gap size (MeanMG) and average maximum marginal gap size (AMaxMG) with a light microscope in the “as-machined” state. The effect of the material on the marginal accuracy was analyzed by multiple pairwise comparisons (Mann–Whitney, U-test, α = 0.05, adjusted by Bonferroni-Holmes method). MeanMG values were as follows: A: 46.92 ± 23.12 μm, B: 48.37 ± 29.72 μm, C: 68.25 ± 28.54 μm, and D: 58.73 ± 21.15 μm. The differences in the MeanMG values proved to be significant for groups A/C (p = 0.0024), A/D (p = 0.008), and B/C (p = 0.0332). AMaxMG values (A: 91.54 ± 23.39 μm, B: 96.86 ± 24.19 μm, C: 120.66 ± 32.75 μm, and D: 100.22 ± 10.83 μm) revealed no significant differences. The material had a significant impact on the marginal accuracy of CAD/CAM-fabricated copings. PMID:29765979
Effect of investment type and mold temperature on casting accuracy and titanium-ceramic bond.
Leal, Mônica Barbosa; Pagnano, Valéria Oliveira; Bezzon, Osvaldo Luiz
2013-01-01
This study evaluated the casting accuracy of crown margins and metal-ceramic shear bond strength (SBS) of pure titanium injected into casting molds made using 2 investment types at 3 mold temperatures. Sixty crown (30-degree beveled finish line) and 60 cylinder (5mm diameter × 8mm high) patterns were divided into 6 groups (n=10), and cast using a phosphate-bonded investment (P) and a magnesium oxide-bonded investment (U), at 400°C (groups P400 and U400), 550°C (groups P550 and U550) and 700°C (groups P700 and U700) mold temperatures. Crown margins were recorded in impression material, the degree of marginal rounding was measured and margin length deficiencies (µm) were calculated. Titanium-ceramic specimens were prepared using Triceram ceramic (2mm high) and SBS was tested. Failure modes were assessed by optical microscopy. Data were subjected to two-way ANOVA and Tukey's HSD test (α=0.05). For casting accuracy, expressed by marginal deficiency (µm), investment U provided more accurate results (64 ± 11) than P (81 ± 23) (p<0.001). The increase in temperature resulted in different effects for the tested investments (p<0.001), as it provided better casting accuracy for U700 (55 ± 7) and worse for P700 (109 ± 18). Casting accuracy at 700°C (82 ± 31) was significantly different from 400°C (69 ± 9) and 550°C (68 ± 9) (p<0.05). For SBS, there was no significant differences among the groups for factors investment (p=0.062) and temperature (p=0.224), or for their interaction (p=0.149). Investment U provided better casting accuracy than investment P. The SBS was similar for all combinations of investments and temperatures.
Vojdani, Mahroo; Torabi, Kianoosh; Atashkar, Berivan; Heidari, Hossein; Torabi Ardakani, Mahshid
2016-01-01
Statement of the Problem: Marginal fitness is the most important criteria for evaluation of the clinical acceptability of a cast restoration. Marginal gap which is due to cement solubility and plaque retention is potentially detrimental to both tooth and periodontal tissues. Purpose: This in vitro study aimed to evaluate the marginal and internal fit of cobalt- chromium (Co-Cr) copings fabricated by two different CAD/CAM systems: (CAD/ milling and CAD/ Ceramill Sintron). Materials and Method: We prepared one machined standard stainless steel master model with following dimensions: 7 mm height, 5mm diameter, 90˚ shoulder marginal finish line with 1 mm width, 10˚ convergence angle and anti-rotational surface on the buccal aspect of the die. There were 10 copings produced from hard presintered Co-Cr blocks according to CAD/ Milling technique and ten copings from soft non- presintered Co-Cr blocks according to CAD/ Ceramill Sintron technique. Marginal and internal accuracies of copings were documented by the replica technique. Replicas were examined at ten reference points under a digital microscope (230X). The Student's t-test was used for statistical analysis. p< 0.001 was considered significant. Results: Statistically significant differences existed between the groups (p< 0.001). The CAD/milling group (hard copings) had a mean marginal discrepancy (MD) of 104 µm, axial discrepancy (AD) of 23 µm and occlusal discrepancy of 130 µm. For CAD/ Ceramill Sintron group, these values were 195 µm (MD), 46 µm (AD), and 232 µm (OD). Internal total discrepancy (ITD) for the CAD/milling group was 77 µm, whereas for the CAD/Ceramill Sintron group was 143 µm. Conclusion: Hard presintered Co-Cr copings had significantly higher marginal and internal accuracies compared to the soft non-presintered copings. PMID:27942545
Augmented reality in a tumor resection model.
Chauvet, Pauline; Collins, Toby; Debize, Clement; Novais-Gameiro, Lorraine; Pereira, Bruno; Bartoli, Adrien; Canis, Michel; Bourdel, Nicolas
2018-03-01
Augmented Reality (AR) guidance is a technology that allows a surgeon to see sub-surface structures, by overlaying pre-operative imaging data on a live laparoscopic video. Our objectives were to evaluate a state-of-the-art AR guidance system in a tumor surgical resection model, comparing the accuracy of the resection with and without the system. Our system has three phases. Phase 1: using the MRI images, the kidney's and pseudotumor's surfaces are segmented to construct a 3D model. Phase 2: the intra-operative 3D model of the kidney is computed. Phase 3: the pre-operative and intra-operative models are registered, and the laparoscopic view is augmented with the pre-operative data. We performed a prospective experimental study on ex vivo porcine kidneys. Alginate was injected into the parenchyma to create pseudotumors measuring 4-10 mm. The kidneys were then analyzed by MRI. Next, the kidneys were placed into pelvictrainers, and the pseudotumors were laparoscopically resected. The AR guidance system allows the surgeon to see tumors and margins using classical laparoscopic instruments, and a classical screen. The resection margins were measured microscopically to evaluate the accuracy of resection. Ninety tumors were segmented: 28 were used to optimize the AR software, and 62 were used to randomly compare surgical resection: 29 tumors were resected using AR and 33 without AR. The analysis of our pathological results showed 4 failures (tumor with positive margins) (13.8%) in the AR group, and 10 (30.3%) in the Non-AR group. There was no complete miss in the AR group, while there were 4 complete misses in the non-AR group. In total, 14 (42.4%) tumors were completely missed or had a positive margin in the non-AR group. Our AR system enhances the accuracy of surgical resection, particularly for small tumors. Crucial information such as resection margins and vascularization could also be displayed.
Amin, Bhavya Mohandas; Aras, Meena Ajay; Chitre, Vidya
2015-01-01
Purpose: The purpose of this in vitro study was to evaluate and compare the primary marginal accuracy of four commercially available provisional materials (Protemp 4, Luxatemp Star, Visalys Temp and DPI tooth moulding powder and liquid) at 2 time intervals (10 and 30 min). Materials and Methods: A customized stainless steel master model containing two interchangeable dies was used for fabrication of provisional crowns. Forty crowns (n = 10) were fabricated, and each crown was evaluated under a stereomicroscope. Vertical marginal discrepancies were noted and compared at 10 min since the start of mixing and then at 30 min. Observations and Results: Protemp 4 showed the least vertical marginal discrepancy (71.59 μ), followed by Luxatemp Star (91.93 μ) at 10 min. DPI showed a marginal discrepancy of 95.94 μ while Visalys Temp crowns had vertical marginal discrepancy of 106.81 μ. There was a significant difference in the marginal discrepancy values of Protemp 4 and Visalys Temp. At 30 min, there was a significant difference between the marginal discrepancy of Protemp 4 crowns (83.11 μ) and Visalys Temp crowns (128.97 μ) and between Protemp 4 and DPI (118.88 μ). No significant differences were observed between Protemp 4 and Luxatemp Star. Conclusion: The vertical marginal discrepancy of temporary crowns fabricated from the four commercially available provisional materials ranged from 71 to 106 μ immediately after fabrication (at 10 min from the start of mix) to 83–128 μ (30 min from the start of mix). The time elapsed after mixing had a significant influence on the marginal accuracy of the crowns. PMID:26097348
A novel method to quantify and compare anatomical shape: application in cervix cancer radiotherapy
NASA Astrophysics Data System (ADS)
Oh, Seungjong; Jaffray, David; Cho, Young-Bin
2014-06-01
Adaptive radiation therapy (ART) had been proposed to restore dosimetric deficiencies during treatment delivery. In this paper, we developed a technique of Geometric reLocation for analyzing anatomical OBjects' Evolution (GLOBE) for a numerical model of tumor evolution under radiation therapy and characterized geometric changes of the target using GLOBE. A total of 174 clinical target volumes (CTVs) obtained from 32 cervical cancer patients were analyzed. GLOBE consists of three main steps; step (1) deforming a 3D surface object to a sphere by parametric active contour (PAC), step (2) sampling a deformed PAC on 642 nodes of icosahedron geodesic dome for reference frame, and step (3) unfolding 3D data to 2D plane for convenient visualization and analysis. The performance was evaluated with respect to (1) convergence of deformation (iteration number and computation time) and (2) accuracy of deformation (residual deformation). Based on deformation vectors from planning CTV to weekly CTVs, target specific (TS) margins were calculated on each sampled node of GLOBE and the systematic (Σ) and random (σ) variations of the vectors were calculated. Population based anisotropic (PBA) margins were generated using van Herk's margin recipe. GLOBE successfully modeled 152 CTVs from 28 patients. Fast convergence was observed for most cases (137/152) with the iteration number of 65 ± 74 (average ± STD) and the computation time of 13.7 ± 18.6 min. Residual deformation of PAC was 0.9 ± 0.7 mm and more than 97% was less than 3 mm. Margin analysis showed random nature of TS-margin. As a consequence, PBA-margins perform similarly to ISO-margins. For example, PBA-margins for 90% patients' coverage with 95% dose level is close to 13 mm ISO-margins in the aspect of target coverage and OAR sparing. GLOBE demonstrates a systematic analysis of tumor motion and deformation of patients with cervix cancer during radiation therapy and numerical modeling of PBA-margin on 642 locations of CTV surface.
Matta, Ragai E; Schmitt, Johannes; Wichmann, Manfred; Holst, Stefan
2012-10-01
Techniques currently applied to determine the marginal accuracy of dental crown restorations yield inadequate information. This investigation aimed to test a new virtual approach for determining the precision of fit of single-crown copings. Zirconia single crown copings were manufactured on 10 gypsum, single-tooth master casts with two different established computer-aided design/computer-assisted manufacture (CAD/CAM) systems (groups A and B). After cementation, the circumferential fit was assessed with an industrial noncontact scanner and virtual 3D analysis, following a triple-scan protocol. Marginal fit was determined by virtual sectioning; each abutment-coping complex was digitally sliced in 360 vertical sections (1 degree per section). Standardized measurement distances for analyzing the marginal fit (z, xy, xyz) were selected, and a crosshair alignment was utilized to determine whether crowns were horizontally and/or vertically too large or small. The Mann-Whitney test was applied to test for differences between groups. Significant differences in the xy direction (P = .008) were measured between groups. Group A showed a greater number of horizontally overextended margins and a higher frequency of xy distances greater than 150 Μm, in addition to a tendency for excessive z distances (P = .095). The mean marginal gap values were clinically acceptable in the present investigation; however, a full circumferential analysis revealed significant differences in marginal coping quality.
Gómez-Cogolludo, Pablo; Castillo-Oyagüe, Raquel; Lynch, Christopher D; Suárez-García, María-Jesús
2013-09-01
The aim of this study was to identify the most appropriate alloy composition and melting technique by evaluating the marginal accuracy of cast metal-ceramic crowns. Seventy standardised stainless-steel abutments were prepared to receive metal-ceramic crowns and were randomly divided into four alloy groups: Group 1: palladium-gold (Pd-Au), Group 2: nickel-chromium-titanium (Ni-Cr-Ti), Group 3: nickel-chromium (Ni-Cr) and Group 4: titanium (Ti). Groups 1, 2 and 3 were in turn subdivided to be melted and cast using: (a) gas oxygen torch and centrifugal casting machine (TC) or (b) induction and centrifugal casting machine (IC). Group 4 was melted and cast using electric arc and vacuum/pressure machine (EV). All of the metal-ceramic crowns were luted with glass-ionomer cement. The marginal fit was measured under an optical microscope before and after cementation using image analysis software. All data was subjected to two-way analysis of variance (ANOVA). Duncan's multiple range test was run for post-hoc comparisons. The Student's t-test was used to investigate the influence of cementation (α=0.05). Uncemented Pd-Au/TC samples achieved the best marginal adaptation, while the worst fit corresponded to the luted Ti/EV crowns. Pd-Au/TC, Ni-Cr and Ti restorations demonstrated significantly increased misfit after cementation. The Ni-Cr-Ti alloy was the most predictable in terms of differences in misfit when either torch or induction was applied before or after cementation. Cemented titanium crowns exceeded the clinically acceptable limit of 120μm. The combination of alloy composition, melting technique, casting method and luting process influences the vertical seal of cast metal-ceramic crowns. An accurate use of the gas oxygen torch may overcome the results attained with the induction system concerning the marginal adaptation of fixed dental prostheses. Copyright © 2013 Elsevier Ltd. All rights reserved.
Bayesian analysis of the flutter margin method in aeroelasticity
Khalil, Mohammad; Poirel, Dominique; Sarkar, Abhijit
2016-08-27
A Bayesian statistical framework is presented for Zimmerman and Weissenburger flutter margin method which considers the uncertainties in aeroelastic modal parameters. The proposed methodology overcomes the limitations of the previously developed least-square based estimation technique which relies on the Gaussian approximation of the flutter margin probability density function (pdf). Using the measured free-decay responses at subcritical (preflutter) airspeeds, the joint non-Gaussain posterior pdf of the modal parameters is sampled using the Metropolis–Hastings (MH) Markov chain Monte Carlo (MCMC) algorithm. The posterior MCMC samples of the modal parameters are then used to obtain the flutter margin pdfs and finally the fluttermore » speed pdf. The usefulness of the Bayesian flutter margin method is demonstrated using synthetic data generated from a two-degree-of-freedom pitch-plunge aeroelastic model. The robustness of the statistical framework is demonstrated using different sets of measurement data. In conclusion, it will be shown that the probabilistic (Bayesian) approach reduces the number of test points required in providing a flutter speed estimate for a given accuracy and precision.« less
Effects of Computer-Aided Manufacturing Technology on Precision of Clinical Metal-Free Restorations.
Lee, Ki-Hong; Yeo, In-Sung; Wu, Benjamin M; Yang, Jae-Ho; Han, Jung-Suk; Kim, Sung-Hun; Yi, Yang-Jin; Kwon, Taek-Ka
2015-01-01
The purpose of this study was to investigate the marginal fit of metal-free crowns made by three different computer-aided design/computer-aided manufacturing (CAD/CAM) systems. The maxillary left first premolar of a dentiform was prepared for all-ceramic crown restoration. Thirty all-ceramic premolar crowns were made, ten each manufactured by the Lava system, Cercon, and Cerec. Ten metal ceramic gold (MCG) crowns served as control. The marginal gap of each sample was measured under a stereoscopic microscope at 75x magnification after cementation. One-way ANOVA and the Duncan's post hoc test were used for data analysis at the significance level of 0.05. The mean (standard deviation) marginal gaps were 70.5 (34.4) μm for the MCG crowns, 87.2 (22.8) μm for Lava, 58.5 (17.6) μm for Cercon, and 72.3 (30.8) μm for Cerec. There were no significant differences in the marginal fit among the groups except that the Cercon crowns had significantly smaller marginal gaps than the Lava crowns (P < 0.001). Within the limitation of this study, all the metal-free restorations made by the digital CAD/CAM systems had clinically acceptable marginal accuracy.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Xiang, H; Hirsch, A; Willins, J
2014-06-01
Purpose: To measure intrafractional prostate motion by time-based stereotactic x-ray imaging and investigate the impact on the accuracy and efficiency of prostate SBRT delivery. Methods: Prostate tracking log files with 1,892 x-ray image registrations from 18 SBRT fractions for 6 patients were retrospectively analyzed. Patient setup and beam delivery sessions were reviewed to identify extended periods of large prostate motion that caused delays in setup or interruptions in beam delivery. The 6D prostate motions were compared to the clinically used PTV margin of 3–5 mm (3 mm posterior, 5 mm all other directions), a hypothetical PTV margin of 2–3 mmmore » (2 mm posterior, 3 mm all other directions), and the rotation correction limits (roll ±2°, pitch ±5° and yaw ±3°) of CyberKnife to quantify beam delivery accuracy. Results: Significant incidents of treatment start delay and beam delivery interruption were observed, mostly related to large pitch rotations of ≥±5°. Optimal setup time of 5–15 minutes was recorded in 61% of the fractions, and optimal beam delivery time of 30–40 minutes in 67% of the fractions. At a default imaging interval of 15 seconds, the percentage of prostate motion beyond PTV margin of 3–5 mm varied among patients, with a mean at 12.8% (range 0.0%–31.1%); and the percentage beyond PTV margin of 2–3 mm was at a mean of 36.0% (range 3.3%–83.1%). These timely detected offsets were all corrected real-time by the robotic manipulator or by operator intervention at the time of treatment interruptions. Conclusion: The durations of patient setup and beam delivery were directly affected by the occurrence of large prostate motion. Frequent imaging of down to 15 second interval is necessary for certain patients. Techniques for reducing prostate motion, such as using endorectal balloon, can be considered to assure consistently higher accuracy and efficiency of prostate SBRT delivery.« less
Minami, Yasunori; Minami, Tomohiro; Hagiwara, Satoru; Ida, Hiroshi; Ueshima, Kazuomi; Nishida, Naoshi; Murakami, Takamichi; Kudo, Masatoshi
2018-05-01
To assess the clinical feasibility of US-US image overlay fusion with evaluation of the ablative margin in radiofrequency ablation (RFA) for hepatocellular carcinoma (HCC). Fifty-three patients with 68 HCCs measuring 0.9-4.0 cm who underwent RFA guided by US-US overlay image fusion were included in this retrospective study. By an overlay of pre-/postoperative US, the tumor image could be projected onto the ablative hyperechoic zone. Therefore, the ablative margin three-dimensionally could be shown during the RFA procedure. US-US image overlay was compared to dynamic CT a few days after RFA for assessment of early treatment response. Accuracy of graded response was calculated, and the performance of US-US image overlay fusion was compared with that of CT using a Kappa agreement test. Technically effective ablation was achieved in a single session, and 59 HCCs (86.8 %) succeeded in obtaining a 5-mm margin on CT. The response with US-US image overlay correctly predicted early CT evaluation with an accuracy of 92.6 % (63/68) (k = 0.67; 95 % CI: 0.39-0.95). US-US image overlay fusion can be proposed as a feasible guidance in RFA with a safety margin and predicts early response of treatment assessment with high accuracy. • US-US image overlay fusion visualizes the ablative margin during RFA procedure. • Visualizing the margin during the procedure can prompt immediate complementary treatment. • US image fusion correlates with the results of early evaluation CT.
Yildirim, Güler; Uzun, Ismail H; Keles, Ali
2017-08-01
The accuracy of recently introduced chairside computer-aided design and computer-aided manufacturing (CAD-CAM) blocks is not well established, and marginal integrity and internal adaptation are not known. The purpose of this in vitro study was to evaluate the marginal and internal adaptation of hybrid and nanoceramics using microcomputed tomography (μ-CT). The marginal and internal adaptation of 3 polymer-infiltrated ceramic-network (PICN) materials (Vita Enamic [VE]; Lava Ultimate [LU]; Vita Suprinity [VS]) were compared with lithium disilicate (IPS e.max.CAD, IPS). Ninety-six specimens (48 dies and 48 crowns) were prepared (n=12 each group) using a chairside CAD-CAM system. The restorations were scanned with μ-CT, with 160 measurements made for each crown, and used in 2-dimensional (2D) analysis. The marginal adaptation of marginal discrepancy (MD), absolute marginal discrepancy (AMD), internal adaptation of shoulder area (SA), axial space (AS), and occlusal space (OS) were compared using appropriate statistical analysis methods (α=.05). Cement volumes were compared using 3D analysis. The IPS blocks showed higher MD (130 μm), AMD (156 μm), SA (111 μm) (P<.05), AS (52 μm), and OS (192 μm) than the other blocks (P<.01). The adaptation values of VS were significantly lower than those of the IPS block (P<.05). The adaption values of the LU and VE blocks were significantly lower than those of others (P<.01) but were statistically similar to one another (P>.05). IPS had the largest cement space at 18 mm 3 (P<.01). The marginal and internal adaptation values were within a clinically acceptable range for all 3 hybrids and nanoceramics tested. Copyright © 2016 Editorial Council for the Journal of Prosthetic Dentistry. Published by Elsevier Inc. All rights reserved.
NASA Astrophysics Data System (ADS)
Al-Gburi, A.; Freeman, C. T.; French, M. C.
2018-06-01
This paper uses gap metric analysis to derive robustness and performance margins for feedback linearising controllers. Distinct from previous robustness analysis, it incorporates the case of output unstructured uncertainties, and is shown to yield general stability conditions which can be applied to both stable and unstable plants. It then expands on existing feedback linearising control schemes by introducing a more general robust feedback linearising control design which classifies the system nonlinearity into stable and unstable components and cancels only the unstable plant nonlinearities. This is done in order to preserve the stabilising action of the inherently stabilising nonlinearities. Robustness and performance margins are derived for this control scheme, and are expressed in terms of bounds on the plant nonlinearities and the accuracy of the cancellation of the unstable plant nonlinearity by the controller. Case studies then confirm reduced conservatism compared with standard methods.
Al Amri, Mohammad D; Al-Johany, Sulieman S; Al-Qarni, Mohammed N; Al-Bakri, Ahmed S; Al-Maflehi, Nassr S; Abualsaud, Haythem S
2018-02-01
The detrimental effect of extruded excess cement on peri-implant tissue has been well documented. Although several techniques have been proposed to reduce this effect by decreasing the amount of extruded cement, how the space size of the abutment screw access channel (SAC) affects the amount of extruded cement and marginal accuracy is unclear. The purpose of this in vitro study was to evaluate the effect of the size of the unfilled space of the abutment SAC on the amount of extruded excess cement and the marginal accuracy of zirconia copings. Twelve implant replicas and corresponding standard abutments were attached and embedded in acrylic resin blocks. Computer-aided design and computer-aided manufacturing (CAD-CAM) zirconia copings with a uniform 30-μm cement space were fabricated by 1 dental technician using the standard method. The copings were temporarily cemented 3 times at different sizes of the left space of the SAC as follows: the nonspaced group (NS), in which the entire SAC was completely filled, the 1-mm-spaced group (1MMS), and the 2-mm-spaced group (2MMS). Abutments and crowns were ultrasonically cleaned, steam cleaned, and air-dried. The excess cement was collected and weighed. To measure the marginal accuracy, 20 measurements were made every 18 degrees along the coping margin at ×300 magnification and compared with the pre-cementation readings. One-way ANOVA was calculated to determine whether the amount of extruded excess cement differed among the 3 groups, and the Tukey test was applied for multiple comparisons (α=.05). The mean weights (mg) of extruded excess cement were NS (33.53 ±1.5), 1MMS (22.97 ±5.4), and 2MMS (15.17 ±5.9). Multiple comparisons showed significant differences in the amount of extruded excess cement among the 3 test groups (P<.001). The mean marginal discrepancy (μm) of the pre-cemented group (29.5 ±8.2) was significantly different (P<.01) from that of the NS (72.3 ±13.7), the 1MMS (70.1 ±19), and the 2MMS group (70.1 ±18.8). No significant differences were found in marginal accuracy among the 3 test groups (P=.942). Within the limitations of this in vitro study, leaving a 2-mm space in the SAC reduced the amount of extruded excess cement by 55% in comparison with the nonspaced abutments. However, no effect was found on the marginal accuracy of zirconia copings. Copyright © 2017 Editorial Council for the Journal of Prosthetic Dentistry. Published by Elsevier Inc. All rights reserved.
Using known map category marginal frequencies to improve estimates of thematic map accuracy
NASA Technical Reports Server (NTRS)
Card, D. H.
1982-01-01
By means of two simple sampling plans suggested in the accuracy-assessment literature, it is shown how one can use knowledge of map-category relative sizes to improve estimates of various probabilities. The fact that maximum likelihood estimates of cell probabilities for the simple random sampling and map category-stratified sampling were identical has permitted a unified treatment of the contingency-table analysis. A rigorous analysis of the effect of sampling independently within map categories is made possible by results for the stratified case. It is noted that such matters as optimal sample size selection for the achievement of a desired level of precision in various estimators are irrelevant, since the estimators derived are valid irrespective of how sample sizes are chosen.
Tsirogiannis, Panagiotis; Reissmann, Daniel R; Heydecke, Guido
2016-09-01
In existing published reports, some studies indicate the superiority of digital impression systems in terms of the marginal accuracy of ceramic restorations, whereas others show that the conventional method provides restorations with better marginal fit than fully digital fabrication. Which impression method provides the lowest mean values for marginal adaptation is inconclusive. The findings from those studies cannot be easily generalized, and in vivo studies that could provide valid and meaningful information are limited in the existing publications. The purpose of this study was to systematically review existing reports and evaluate the marginal fit of ceramic single-tooth restorations after either digital or conventional impression methods by combining the available evidence in a meta-analysis. The search strategy for this systematic review of the publications was based on a Population, Intervention, Comparison, and Outcome (PICO) framework. For the statistical analysis, the mean marginal fit values of each study were extracted and categorized according to the impression method to calculate the mean value, together with the 95% confidence intervals (CI) of each category, and to evaluate the impact of each impression method on the marginal adaptation by comparing digital and conventional techniques separately for in vitro and in vivo studies. Twelve studies were included in the meta-analysis from the 63 identified records after database searching. For the in vitro studies, where ceramic restorations were fabricated after conventional impressions, the mean value of the marginal fit was 58.9 μm (95% CI: 41.1-76.7 μm), whereas after digital impressions, it was 63.3 μm (95% CI: 50.5-76.0 μm). In the in vivo studies, the mean marginal discrepancy of the restorations after digital impressions was 56.1 μm (95% CI: 46.3-65.8 μm), whereas after conventional impressions, it was 79.2 μm (95% CI: 59.6-98.9 μm) No significant difference was observed regarding the marginal discrepancy of single-unit ceramic restorations fabricated after digital or conventional impressions. Copyright © 2016 Editorial Council for the Journal of Prosthetic Dentistry. Published by Elsevier Inc. All rights reserved.
Cogolludo, Pablo G; Suarez, María J; Peláez, Jesús; Lozano, José F L
2010-01-01
The aim of this study was to analyze the influence of melting and casting procedures and the cervical finish line design on the marginal fit of nickel-chromium-titanium alloy crowns. Sixty standardized specimens were prepared to receive metal-ceramic crowns and were divided into two groups according to the cervical finish line: chamfer or rounded shoulder. Three melting and casting procedures were analyzed: (1) induction-centrifuge (IC), (2) gas oxygen torch-centrifuge (TC), and (3) induction-vacuum/pressure (IP). The marginal fit was measured with an image analysis system. Significant differences (P =.005) were observed among the groups, with TC showing the lowest discrepancies (45.87 μm). No significant differences were observed between the two finish lines. The accuracy of fit achieved for the groups analyzed may be regarded as within the range of clinical acceptance.
Margin and sensitivity methods for security analysis of electric power systems
NASA Astrophysics Data System (ADS)
Greene, Scott L.
Reliable operation of large scale electric power networks requires that system voltages and currents stay within design limits. Operation beyond those limits can lead to equipment failures and blackouts. Security margins measure the amount by which system loads or power transfers can change before a security violation, such as an overloaded transmission line, is encountered. This thesis shows how to efficiently compute security margins defined by limiting events and instabilities, and the sensitivity of those margins with respect to assumptions, system parameters, operating policy, and transactions. Security margins to voltage collapse blackouts, oscillatory instability, generator limits, voltage constraints and line overloads are considered. The usefulness of computing the sensitivities of these margins with respect to interarea transfers, loading parameters, generator dispatch, transmission line parameters, and VAR support is established for networks as large as 1500 buses. The sensitivity formulas presented apply to a range of power system models. Conventional sensitivity formulas such as line distribution factors, outage distribution factors, participation factors and penalty factors are shown to be special cases of the general sensitivity formulas derived in this thesis. The sensitivity formulas readily accommodate sparse matrix techniques. Margin sensitivity methods are shown to work effectively for avoiding voltage collapse blackouts caused by either saddle node bifurcation of equilibria or immediate instability due to generator reactive power limits. Extremely fast contingency analysis for voltage collapse can be implemented with margin sensitivity based rankings. Interarea transfer can be limited by voltage limits, line limits, or voltage stability. The sensitivity formulas presented in this thesis apply to security margins defined by any limit criteria. A method to compute transfer margins by directly locating intermediate events reduces the total number of loadflow iterations required by each margin computation and provides sensitivity information at minimal additional cost. Estimates of the effect of simultaneous transfers on the transfer margins agree well with the exact computations for a network model derived from a portion of the U.S grid. The accuracy of the estimates over a useful range of conditions and the ease of obtaining the estimates suggest that the sensitivity computations will be of practical value.
Whole specimen intraoperative frozen section analysis. Experience with 1082 basal cell carcinomas.
Kedilioglu, Muhammed A; Bos, Paul G; De Jong, Kim; Noordzij, Niels A; Kibbelaar, Robby E; Lapid, Oren; Mouës, Chantal M
2018-01-01
Basal cell carcinomas (BCCs) excised leaving positive tumour margins, are at a higher risk of recurrence. Accordingly, complete tumour removal with preservation of healthy tissue, aiming for low recurrence rates, is the main goal in treating BCCs. The present study aimed to identify the reliability of the Whole Specimen Intraoperative Frozen Section Analysis (WIFSA) technique by comparing intraoperative WIFSA and postoperative Formalin-Fixed Paraffin-Embedded section analysis (FFPE) results in 1082 basal cell carcinomas and by assessing the recurrence rates during a follow-up period up to 10 years. A single-centre retrospective cohort of all patients with BCC of the face receiving surgical excision with the WIFSA method between January 2007 and December 2013 was evaluated. We compared the intraoperative frozen section results with postoperative FFPE in order to assess accuracy of the WIFSA. Recurrence rates were assessed among all BCCs with a tumour-free margin at final excision that had a minimum follow-up of 6 months. A total of 996 patients with 1082 BCCs were treated with the WIFSA. Overall agreement of WIFSA with conventional postoperative FFPE was 98·8%, sensitivity and specificity being 99·0% and 98·7% respectively. We excluded 23 BCCs that still had positive tumour margins at the end of the procedure and another 67 for the analysis of recurrence rate because follow-up was shorter than 6 months. A total of 992 BCCs with a tumour-free margin at final excision had a mean follow-up of 5·6 years (mean 67 ± 27·7 months (range 6-117 months)). The total recurrence rate was 2·1% (21 out of 992 BCCs). The recurrence rate among the primary tumours was 1·6% (13 out of 828 cases) and 4·9% among the recurring tumours (8 out of 164 cases). This study indicates that, in patients with primary or recurring BCCs, WIFSA provides a high accuracy for intraoperative specimen analysis and has a low recurrence rate after a mean follow-up of 5·6 years. This research did not receive any specific grant from funding agencies in the public, commercial, or not-for-profit sectors. Copyright © 2017 Elsevier Ltd, BASO ~ The Association for Cancer Surgery, and the European Society of Surgical Oncology. All rights reserved.
Speed-Accuracy Response Models: Scoring Rules Based on Response Time and Accuracy
ERIC Educational Resources Information Center
Maris, Gunter; van der Maas, Han
2012-01-01
Starting from an explicit scoring rule for time limit tasks incorporating both response time and accuracy, and a definite trade-off between speed and accuracy, a response model is derived. Since the scoring rule is interpreted as a sufficient statistic, the model belongs to the exponential family. The various marginal and conditional distributions…
Shokry, Tamer E; Attia, Mazen; Mosleh, Ihab; Elhosary, Mohamed; Hamza, Tamer; Shen, Chiayi
2010-01-01
Titanium is the most biocompatible metal used for dental casting; however, there is concern about its marginal accuracy after porcelain application since this aspect has direct influence on marginal fit. The purpose of this study was to determine the effect that metal selection and the porcelain firing procedure have on the marginal accuracy of metal ceramic prostheses. Cast CP Ti, milled CP Ti, cast Ti-6Al-7Nb, and cast Ni-Cr copings (n=5) were fired with compatible porcelains (Triceram for titanium-based metals and VITA VMK 95 for Ni-Cr alloy). The Ni-Cr alloy fired with its porcelain served as the control. Photographs of metal copings placed on a master die were made. Marginal discrepancy was determined on the photographs using an image processing program at 8 predetermined locations before airborne-particle abrasion for porcelain application, after firing of the opaque layer, and after firing of the dentin layer. Repeated-measures 2-way ANOVA was used to investigate the effect of metal selection and firing stage, and paired t tests were used to determine the effect of each firing stage within each material group (alpha=.05). ANOVA showed that both metal selection and firing stage significantly influenced the measured marginal discrepancy (P<.001), and there was interaction between the 2 variables (P<.001). Student-Newman-Keuls multiple comparison tests showed that there were significant differences between any 2 metals compared, at each stage of measurement. Paired t tests showed that significant changes in marginal discrepancy occurred with opaque firing on milled CP Ti (P=.017) and cast Ti-6Al-7Nb alloy (P=.003). Titanium copings fabricated by CAD/CAM demonstrated the least marginal discrepancy among all groups, while the base metal (Ni-Cr) groups exhibited the most discrepancy of all groups tested. Copyright 2010 The Editorial Council of the Journal of Prosthetic Dentistry. Published by Mosby, Inc. All rights reserved.
Quantitative measurement of marginal disintegration of ceramic inlays.
Hayashi, Mikako; Tsubakimoto, Yuko; Takeshige, Fumio; Ebisu, Shigeyuki
2004-01-01
The objectives of this study include establishing a method for quantitative measurement of marginal change in ceramic inlays and clarifying their marginal disintegration in vivo. An accurate CCD optical laser scanner system was used for morphological measurement of the marginal change of ceramic inlays. The accuracy of the CCD measurement was assessed by comparing it with microscopic measurement. Replicas of 15 premolars restored with Class II ceramic inlays at the time of placement and eight years after restoration were used for morphological measurement by means of the CCD laser scanner system. Occlusal surfaces of the restored teeth were scanned and cross-sections of marginal areas were computed with software. Marginal change was defined as the area enclosed by two profiles obtained by superimposing two cross-sections of the same location at two different times and expressing the maximum depth and mean area of the area enclosed. The accuracy of this method of measurement was 4.3 +/- 3.2 microm in distance and 2.0 +/- 0.6% in area. Quantitative marginal changes for the eight-year period were 10 x 10 microm in depth and 50 x 10(3) microm2 in area at the functional cusp area and 7 x 10 microm in depth and 28 x 10(3) microm2 in area at the non-functional cusp area. Marginal disintegration at the functional cusp area was significantly greater than at the non-functional cusp area (Wilcoxon signed-ranks test, p < 0.05). This study constitutes a quantitative measurement of in vivo deterioration in marginal adaptation of ceramic inlays and indicates that occlusal force may accelerate marginal disintegration.
Rai, Rathika; Kumar, S Arun; Prabhu, R; Govindan, Ranjani Thillai; Tanveer, Faiz Mohamed
2017-01-01
Accuracy in fit of cast metal restoration has always remained as one of the primary factors in determining the success of the restoration. A well-fitting restoration needs to be accurate both along its margin and with regard to its internal surface. The aim of the study is to evaluate the marginal fit of metal ceramic crowns obtained by conventional inlay casting wax pattern using conventional impression with the metal ceramic crowns obtained by computer-aided design and computer-aided manufacturing (CAD/CAM) technique using direct and indirect optical scanning. This in vitro study on preformed custom-made stainless steel models with former assembly that resembles prepared tooth surfaces of standardized dimensions comprised three groups: the first group included ten samples of metal ceramic crowns fabricated with conventional technique, the second group included CAD/CAM-milled direct metal laser sintering (DMLS) crowns using indirect scanning, and the third group included DMLS crowns fabricated by direct scanning of the stainless steel model. The vertical marginal gap and the internal gap were evaluated with the stereomicroscope (Zoomstar 4); post hoc Turkey's test was used for statistical analysis. One-way analysis of variance method was used to compare the mean values. Metal ceramic crowns obtained from direct optical scanning showed the least marginal and internal gap when compared to the castings obtained from inlay casting wax and indirect optical scanning. Indirect and direct optical scanning had yielded results within clinically acceptable range.
Gonzalo, Esther; Suárez, María J; Serrano, Benjamin; Lozano, José F L
2009-01-01
The purpose of this study was to compare two measurement methods for the external marginal fit of zirconia posterior fixed partial dentures (FPDs) fabricated using computer-aided design/manufacturing technology and metal-ceramic posterior FPDs fabricated using the conventional lost-wax technique. The null hypothesis was that there would be no differences between the measurement methods. Forty standardized steel specimens were prepared to receive posterior three-unit FPDs. Specimens were divided into four groups (n = 10): (1) metal-ceramic, (2) Procera Bridge Zirconia, (3) Lava AllCeramic System, and (4) Vita In-Ceram YZ 2000. All FPDs were luted with glass-ionomer cement (Ketac Cem EasyMix, 3M ESPE). Two measurement methods were used to analyze marginal fit: an image analysis (IA) program and a scanning electron microscope (SEM) (JEOL JSM-6400) with magnifications of 340 and 31,000, respectively. Marginal fit was measured at the same point on each abutment. Significant interaction was observed between measurement method and material (P = .0019). Therefore, the measurement method is not independent of the restoration material. Differences among groups were observed for IA (P = .0001) and SEM (P = .0013). Significant differences were observed for the Procera (P = .0050) and metal-ceramic (P = .0039) specimen groups when both measurement methods were evaluated separately. Accuracy of fit achieved by the four groups analyzed was within the range of clinical acceptance, yielding Procera Bridge Zirconia to have the best marginal fit using both measurement methods.
Concept Mapping Improves Metacomprehension Accuracy among 7th Graders
ERIC Educational Resources Information Center
Redford, Joshua S.; Thiede, Keith W.; Wiley, Jennifer; Griffin, Thomas D.
2012-01-01
Two experiments explored concept map construction as a useful intervention to improve metacomprehension accuracy among 7th grade students. In the first experiment, metacomprehension was marginally better for a concept mapping group than for a rereading group. In the second experiment, metacomprehension accuracy was significantly greater for a…
NASA Astrophysics Data System (ADS)
Liu, Tuo; Chen, Changshui; Shi, Xingzhe; Liu, Chengyong
2016-05-01
The Raman spectra of tissue of 20 brain tumor patients was recorded using a confocal microlaser Raman spectroscope with 785 nm excitation in vitro. A total of 133 spectra were investigated. Spectra peaks from normal white matter tissue and tumor tissue were analyzed. Algorithms, such as principal component analysis, linear discriminant analysis, and the support vector machine, are commonly used to analyze spectral data. However, in this study, we employed the learning vector quantization (LVQ) neural network, which is typically used for pattern recognition. By applying the proposed method, a normal diagnosis accuracy of 85.7% and a glioma diagnosis accuracy of 89.5% were achieved. The LVQ neural network is a recent approach to excavating Raman spectra information. Moreover, it is fast and convenient, does not require the spectra peak counterpart, and achieves a relatively high accuracy. It can be used in brain tumor prognostics and in helping to optimize the cutting margins of gliomas.
NASA Technical Reports Server (NTRS)
Mcknight, R. D.; Blalock, T. V.; Kennedy, E. J.
1974-01-01
The design, analysis, and experimental evaluation of an optimum performance torque current generator for use with strapdown gyroscopes, is presented. Among the criteria used to evaluate the design were the following: (1) steady-state accuracy; (2) margins of stability against self-oscillation; (3) temperature variations; (4) aging; (5) static errors drift errors, and transient errors, (6) classical frequency and time domain characteristics; and (7) the equivalent noise at the input of the comparater operational amplifier. The DC feedback loop of the torque current generator was approximated as a second-order system. Stability calculations for gain margins are discussed. Circuit diagrams are shown and block diagrams showing the implementation of the torque current generator are discussed.
Analysis of Bonded Joints Between the Facesheet and Flange of Corrugated Composite Panels
NASA Technical Reports Server (NTRS)
Yarrington, Phillip W.; Collier, Craig S.; Bednarcyk, Brett A.
2008-01-01
This paper outlines a method for the stress analysis of bonded composite corrugated panel facesheet to flange joints. The method relies on the existing HyperSizer Joints software, which analyzes the bonded joint, along with a beam analogy model that provides the necessary boundary loading conditions to the joint analysis. The method is capable of predicting the full multiaxial stress and strain fields within the flange to facesheet joint and thus can determine ply-level margins and evaluate delamination. Results comparing the method to NASTRAN finite element model stress fields are provided illustrating the accuracy of the method.
NASA Technical Reports Server (NTRS)
Davidson, Frederic M.; Field, Christopher T.; Sun, Xiaoli
1996-01-01
We report here the design and the performance measurements of the breadboard receiver of the Geoscience Laser Altimeter System (GLAS). The measured ranging accuracy was better than 2 cm and 10 cm for 5 ns and 30 ns wide received laser pulses under the expected received signal level, which agreed well with the theoretical analysis. The measured receiver sensitivity or the link margin was also consistent with the theory. The effects of the waveform digitizer sample rate and resolution were also measured.
Application of Replica Technique and SEM in Accuracy Measurement of Ceramic Crowns
NASA Astrophysics Data System (ADS)
Trifkovic, B.; Budak, I.; Todorovic, A.; Hodolic, J.; Puskar, T.; Jevremovic, D.; Vukelic, D.
2012-01-01
The paper presents a comparative study of the measuring values of the marginal gap related to the ceramic crowns made by dental CAD/CAM system using the replica technique and SEM. The study was conducted using three experimental groups, which consisted of ceramic crowns manufactured by the Cerec CAD/CAM system. The scanning procedure was carried out using three specialized dental 3D digitization systems from the Cerec family - two types of extraoral optical scanning systems and an intraoral optical scanner. Measurements of the marginal gap were carried out using the replica technique and SEM. The comparison of aggregate values of the marginal gap using the replica technique showed a statistically significant difference between the systems. The measured values of marginal gaps of ceramic crowns using the replica technique were significantly lower compared to those measured by SEM. The results indicate that the choice of technique for measuring the accuracy of ceramic crowns influences the final results of investigation.
Accuracy and Consistency of Respiratory Gating in Abdominal Cancer Patients
DOE Office of Scientific and Technical Information (OSTI.GOV)
Ge, Jiajia; Santanam, Lakshmi; Yang, Deshan
2013-03-01
Purpose: To evaluate respiratory gating accuracy and intrafractional consistency for abdominal cancer patients treated with respiratory gated treatment on a regular linear accelerator system. Methods and Materials: Twelve abdominal patients implanted with fiducials were treated with amplitude-based respiratory-gated radiation therapy. On the basis of daily orthogonal fluoroscopy, the operator readjusted the couch position and gating window such that the fiducial was within a setup margin (fiducial-planning target volume [f-PTV]) when RPM indicated “beam-ON.” Fifty-five pre- and post-treatment fluoroscopic movie pairs with synchronized respiratory gating signal were recorded. Fiducial motion traces were extracted from the fluoroscopic movies using a template matchingmore » algorithm and correlated with f-PTV by registering the digitally reconstructed radiographs with the fluoroscopic movies. Treatment was determined to be “accurate” if 50% of the fiducial area stayed within f-PTV while beam-ON. For movie pairs that lost gating accuracy, a MATLAB program was used to assess whether the gating window was optimized, the external-internal correlation (EIC) changed, or the patient moved between movies. A series of safety margins from 0.5 mm to 3 mm was added to f-PTV for reassessing gating accuracy. Results: A decrease in gating accuracy was observed in 44% of movie pairs from daily fluoroscopic movies of 12 abdominal patients. Three main causes for inaccurate gating were identified as change of global EIC over time (∼43%), suboptimal gating setup (∼37%), and imperfect EIC within movie (∼13%). Conclusions: Inconsistent respiratory gating accuracy may occur within 1 treatment session even with a daily adjusted gating window. To improve or maintain gating accuracy during treatment, we suggest using at least a 2.5-mm safety margin to account for gating and setup uncertainties.« less
Accuracy of digital images in the detection of marginal microleakage: an in vitro study.
Alvarenga, Fábio Augusto; Andrade, Marcelo Ferrarezi; Pinelli, Camila; Rastelli, Alessanda Nara; Victorino, Keli Regina; Loffredo, Leonor de
2012-08-01
To evaluate the accuracy of Image Tool Software 3.0 (ITS 3.0) to detect marginal microleakage using the stereomicroscope as the validation criterion and ITS 3.0 as the tool under study. Class V cavities were prepared at the cementoenamel junction of 61 bovine incisors, and 53 halves of them were used. Using the stereomicroscope, microleakage was classified dichotomously: presence or absence. Next, ITS 3.0 was used to obtain measurements of the microleakage, so that 0.75 was taken as the cut-off point, and values equal to or greater than 0.75 indicated its presence, while values between 0.00 and 0.75 indicated its absence. Sensitivity and specificity were calculated by point and given as 95% confidence interval (95% CI). The accuracy of the ITS 3.0 was verified with a sensitivity of 0.95 (95% CI: 0.89 to 1.00) and a specificity of 0.92 (95% CI: 0.84 to 0.99). Digital diagnosis of marginal microleakage using ITS 3.0 was sensitive and specific.
Generalized Full-Information Item Bifactor Analysis
Cai, Li; Yang, Ji Seung; Hansen, Mark
2011-01-01
Full-information item bifactor analysis is an important statistical method in psychological and educational measurement. Current methods are limited to single group analysis and inflexible in the types of item response models supported. We propose a flexible multiple-group item bifactor analysis framework that supports a variety of multidimensional item response theory models for an arbitrary mixing of dichotomous, ordinal, and nominal items. The extended item bifactor model also enables the estimation of latent variable means and variances when data from more than one group are present. Generalized user-defined parameter restrictions are permitted within or across groups. We derive an efficient full-information maximum marginal likelihood estimator. Our estimation method achieves substantial computational savings by extending Gibbons and Hedeker’s (1992) bifactor dimension reduction method so that the optimization of the marginal log-likelihood only requires two-dimensional integration regardless of the dimensionality of the latent variables. We use simulation studies to demonstrate the flexibility and accuracy of the proposed methods. We apply the model to study cross-country differences, including differential item functioning, using data from a large international education survey on mathematics literacy. PMID:21534682
Q-elastography in the presurgical diagnosis of thyroid nodules with indeterminate cytology.
Cantisani, Vito; Ulisse, Salvatore; Guaitoli, Eleonora; De Vito, Corrado; Caruso, Riccardo; Mocini, Renzo; D'Andrea, Vito; Ascoli, Valeria; Antonaci, Alfredo; Catalano, Carlo; Nardi, Francesco; Redler, Adriano; Ricci, Paolo; De Antoni, Enrico; Sorrenti, Salvatore
2012-01-01
Quantitative ultrasound (US) elastography (Q-USE), able to evaluate tissue stiffness has been indicated as a new diagnostic tool to differentiate benign from malignant thyroid lesions. Aim of this prospective study, conducted at the Department of Surgical Sciences, of the "Sapienza" University of Rome, was to evaluate the diagnostic accuracy of Q-USE, compared with US parameters, in thyroid nodules with indeterminate cytology (Thy3).The case study included 140 nodules from 140 consecutive patients. Patient's thyroid nodules were evaluated by Q-USE, measuring the strain ratio (SR) of stiffness between nodular and surrounding normal thyroid tissue, and conventional US parameters prior fine-needle aspiration cytology. Those with Thy3 diagnosis were included in the study. Forty of the nodules analyzed harbored a malignant lesion. Q-USE demonstrated that malignant nodules have a significant higher stiffness with respect to benign one and an optimun SR cut-off value of 2.05 was individuated following ROC analysis. Univariate analysis showed that hypoechogenicity, irregular margins and SR >2.05 associated with malignancy, with an accuracy of 67.2%, 81,0% and 89.8%, respectively. Data were unaffected by nodule size or thyroiditis. These findings were confirmed in multivariate analysis demonstrating a significant association of the SR and the irregular margins with thyroid nodule's malignancy. In conclusion, we demonstrated the diagnostic utility of Q-USE in the differential diagnosis of thyroid nodules with indeterminate cytology that, if confirmed, could be of major clinical utility in patients' presurgical selection.
Q-Elastography in the Presurgical Diagnosis of Thyroid Nodules with Indeterminate Cytology
Guaitoli, Eleonora; De Vito, Corrado; Caruso, Riccardo; Mocini, Renzo; D’Andrea, Vito; Ascoli, Valeria; Antonaci, Alfredo; Catalano, Carlo; Nardi, Francesco; Redler, Adriano; Ricci, Paolo; De Antoni, Enrico; Sorrenti, Salvatore
2012-01-01
Quantitative ultrasound (US) elastography (Q-USE), able to evaluate tissue stiffness has been indicated as a new diagnostic tool to differentiate benign from malignant thyroid lesions. Aim of this prospective study, conducted at the Department of Surgical Sciences, of the “Sapienza” University of Rome, was to evaluate the diagnostic accuracy of Q-USE, compared with US parameters, in thyroid nodules with indeterminate cytology (Thy3).The case study included 140 nodules from 140 consecutive patients. Patient’s thyroid nodules were evaluated by Q-USE, measuring the strain ratio (SR) of stiffness between nodular and surrounding normal thyroid tissue, and conventional US parameters prior fine-needle aspiration cytology. Those with Thy3 diagnosis were included in the study. Forty of the nodules analyzed harbored a malignant lesion. Q-USE demonstrated that malignant nodules have a significant higher stiffness with respect to benign one and an optimun SR cut-off value of 2.05 was individuated following ROC analysis. Univariate analysis showed that hypoechogenicity, irregular margins and SR >2.05 associated with malignancy, with an accuracy of 67.2%, 81,0% and 89.8%, respectively. Data were unaffected by nodule size or thyroiditis. These findings were confirmed in multivariate analysis demonstrating a significant association of the SR and the irregular margins with thyroid nodule’s malignancy. In conclusion, we demonstrated the diagnostic utility of Q-USE in the differential diagnosis of thyroid nodules with indeterminate cytology that, if confirmed, could be of major clinical utility in patients’ presurgical selection. PMID:23209819
DOE Office of Scientific and Technical Information (OSTI.GOV)
Li, Winnie, E-mail: winnie.li@rmp.uhn.on.ca; Department of Radiation Oncology, University of Toronto, Toronto, Ontario; Purdie, Thomas G.
2011-12-01
Purpose: To assess intrafractional geometric accuracy of lung stereotactic body radiation therapy (SBRT) patients treated with volumetric image guidance. Methods and Materials: Treatment setup accuracy was analyzed in 133 SBRT patients treated via research ethics board-approved protocols. For each fraction, a localization cone-beam computed tomography (CBCT) scan was acquired for soft-tissue registration to the internal target volume, followed by a couch adjustment for positional discrepancies greater than 3 mm, verified with a second CBCT scan. CBCT scans were also performed at intrafraction and end fraction. Patient positioning data from 2047 CBCT scans were recorded to determine systematic ({Sigma}) and randommore » ({sigma}) uncertainties, as well as planning target volume margins. Data were further stratified and analyzed by immobilization method (evacuated cushion [n = 75], evacuated cushion plus abdominal compression [n = 33], or chest board [n = 25]) and by patients' Eastern Cooperative Oncology Group performance status (PS): 0 (n = 31), 1 (n = 70), or 2 (n = 32). Results: Using CBCT internal target volume was matched within {+-}3 mm in 16% of all fractions at localization, 89% at verification, 72% during treatment, and 69% after treatment. Planning target volume margins required to encompass residual setup errors after couch corrections (verification CBCT scans) were 4 mm, and they increased to 5 mm with target intrafraction motion (post-treatment CBCT scans). Small differences (<1 mm) in the cranial-caudal direction of target position were observed between the immobilization cohorts in the localization, verification, intrafraction, and post-treatment CBCT scans (p < 0.01). Positional drift varied according to patient PS, with the PS 1 and 2 cohorts drifting out of position by mid treatment more than the PS 0 cohort in the cranial-caudal direction (p = 0.04). Conclusions: Image guidance ensures high geometric accuracy for lung SBRT irrespective of immobilization method or PS. A 5-mm setup margin suffices to address intrafraction motion. This setup margin may be further reduced by strategies such as frequent image guidance or volumetric arc therapy to correct or limit intrafraction motion.« less
Li, Winnie; Purdie, Thomas G; Taremi, Mojgan; Fung, Sharon; Brade, Anthony; Cho, B C John; Hope, Andrew; Sun, Alexander; Jaffray, David A; Bezjak, Andrea; Bissonnette, Jean-Pierre
2011-12-01
To assess intrafractional geometric accuracy of lung stereotactic body radiation therapy (SBRT) patients treated with volumetric image guidance. Treatment setup accuracy was analyzed in 133 SBRT patients treated via research ethics board-approved protocols. For each fraction, a localization cone-beam computed tomography (CBCT) scan was acquired for soft-tissue registration to the internal target volume, followed by a couch adjustment for positional discrepancies greater than 3 mm, verified with a second CBCT scan. CBCT scans were also performed at intrafraction and end fraction. Patient positioning data from 2047 CBCT scans were recorded to determine systematic (Σ) and random (σ) uncertainties, as well as planning target volume margins. Data were further stratified and analyzed by immobilization method (evacuated cushion [n=75], evacuated cushion plus abdominal compression [n=33], or chest board [n=25]) and by patients' Eastern Cooperative Oncology Group performance status (PS): 0 (n=31), 1 (n=70), or 2 (n=32). Using CBCT internal target volume was matched within ±3 mm in 16% of all fractions at localization, 89% at verification, 72% during treatment, and 69% after treatment. Planning target volume margins required to encompass residual setup errors after couch corrections (verification CBCT scans) were 4 mm, and they increased to 5 mm with target intrafraction motion (post-treatment CBCT scans). Small differences (<1 mm) in the cranial-caudal direction of target position were observed between the immobilization cohorts in the localization, verification, intrafraction, and post-treatment CBCT scans (p<0.01). Positional drift varied according to patient PS, with the PS 1 and 2 cohorts drifting out of position by mid treatment more than the PS 0 cohort in the cranial-caudal direction (p=0.04). Image guidance ensures high geometric accuracy for lung SBRT irrespective of immobilization method or PS. A 5-mm setup margin suffices to address intrafraction motion. This setup margin may be further reduced by strategies such as frequent image guidance or volumetric arc therapy to correct or limit intrafraction motion. Copyright © 2011 Elsevier Inc. All rights reserved.
Brachtel, Elena F.; Johnson, Nicole B.; Huck, Amelia E.; Rice-Stitt, Travis L.; Vangel, Mark G.; Smith, Barbara L.; Tearney, Guillermo J.; Kang, Dongkyun
2016-01-01
A large percentage of breast cancer patients treated with breast conserving surgery need to undergo multiple surgeries due to positive margins found during post-operative margin assessment. Carcinomas could be removed completely during the initial surgery and additional surgery avoided if positive margins can be determined intra-operatively. Spectrally-encoded confocal microscopy (SECM) is a high-speed reflectance confocal microscopy technology that has a potential to rapidly image the entire surgical margin at sub-cellular resolution and accurately determine margin status intra-operatively. In this paper, in order to test feasibility of using SECM for intra-operative margin assessment, we have evaluated the diagnostic accuracy of SECM for detecting various types of breast cancers. Forty-six surgically-removed breast specimens were imaged with a SECM system. Side-by-side comparison between SECM and histologic images showed that SECM images can visualize key histomorphologic patterns of normal/benign and malignant breast tissues. Small (500 µm × 500 µm) spatially-registered SECM and histologic images (n=124 for each) were diagnosed independently by three pathologists with expertise in breast pathology. Diagnostic accuracy of SECM for determining malignant tissues was high, average sensitivity of 0.91, specificity of 0.93, positive predictive value of 0.95, and negative predictive value of 0.87. Intra-observer agreement and inter-observer agreement for SECM were also high, 0.87 and 0.84, respectively. Results from this study suggest that SECM may be developed into an intra-operative margin assessment tool for guiding breast cancer excisions. PMID:26779830
Multi-look fusion identification: a paradigm shift from quality to quantity in data samples
NASA Astrophysics Data System (ADS)
Wong, S.
2009-05-01
A multi-look identification method known as score-level fusion is found to be capable of achieving very high identification accuracy, even when low quality target signatures are used. Analysis using measured ground vehicle radar signatures has shown that a 97% correct identification rate can be achieved using this multi-look fusion method; in contrast, only a 37% accuracy rate is obtained when single target signature input is used. The results suggest that quantity can be used to replace quality of the target data in improving identification accuracy. With the advent of sensor technology, a large amount of target signatures of marginal quality can be captured routinely. This quantity over quality approach allows maximum exploitation of the available data to improve the target identification performance and this could have the potential of being developed into a disruptive technology.
In vitro investigation of marginal accuracy of implant-supported screw-retained partial dentures.
Koke, U; Wolf, A; Lenz, P; Gilde, H
2004-05-01
Mismatch occurring during the fabrication of implant-supported dentures may induce stress to the peri-implant bone. The purpose of this study was to investigate the influence of two different alloys and the fabrication method on the marginal accuracy of cast partial dentures. Two laboratory implants were bonded into an aluminium block so that the distance between their longitudinal axes was 21 mm. Frameworks designed for screw-retained partial dentures were cast either with pure titanium (rematitan) or with a CoCr-alloy (remanium CD). Two groups of 10 frameworks were cast in a single piece. The first group was made of pure titanium, and the second group of a CoCr-alloy (remanium CD). A third group of 10 was cast in two pieces and then laser-welded onto a soldering model. This latter group was also made of the CoCr-alloy. All the frameworks were screwed to the original model with defined torque. Using light microscopy, marginal accuracy was determined by measuring vertical gaps at eight defined points around each implant. Titanium frameworks cast in a single piece demonstrated mean vertical gaps of 40 microm (s.d. = 11 microm) compared with 72 microm (s.d. = 40 microm) for CoCr-frameworks. These differences were not significant (U-test, P = 0.124) because of a considerable variation of the values for CoCr-frameworks (minimum: 8 microm and maximum: 216 microm). However, frameworks cast in two pieces and mated with a laser showed significantly better accuracy in comparison with the other experimental groups (mean: 17 microm +/- 6; P < 0.01). (i) The fit of implant-supported partial dentures cast with pure titanium in a single piece is preferable to that of those made with the CoCr-alloy and (ii) the highest accuracy can be achieved by using a two-piece casting technique combined with laser welding. Manufacturing the framework pieces separately and then welding them together provides the best marginal fit.
Baxter, Suzanne Domel; Smith, Albert F.; Nichols, Michele D.; Guinn, Caroline H.; Hardin, James W.
2007-01-01
This secondary analysis investigated the influence of body mass index (BMI) category and sex on reporting accuracy during multiple 24-hour dietary recalls. On three occasions, each of 79 children (40 girls) was observed eating school meals and interviewed the next morning about the previous day’s intake, with ≥ 25 days between any two consecutive occasions for a child. Using age/sex BMI percentiles, we categorized 48 children as healthy weight (≥ 5th percentile <85th), 14 as at risk of overweight (≥ 85th percentile <95th), and 17 as overweight (≥95th percentile). A repeated-measures analysis was conducted for each of five outcomes (number of items observed eaten, number of items reported eaten, omission rate, intrusion rate, total inaccuracy). For items observed, BMI category x trial was marginally significant (P=0.079); over trials, this outcome was stable for healthy-weight children, decreased and stabilized for at-risk-of-overweight children, and was stable and decreased for overweight children. This outcome was greatest for overweight children and least for healthy-weight children (P=0.015). For items reported, no significant effects were found. For omission rate (P=0.028) and intrusion rate (P=0.083), BMI category x trial was significant and marginally significant; over trials, both decreased for healthy-weight children, decreased and stabilized for at-risk-of-overweight children, and increased and stabilized for overweight children. Total inaccuracy decreased slightly over trials (P=0.076); this outcome was greater for boys than for girls (P=0.049). Results suggest that children’s dietary reporting accuracy over multiple recalls varies by BMI category. Validation studies with adequate samples for each BMI category, sex, and race are needed. PMID:17541449
High Accuracy Transistor Compact Model Calibrations
DOE Office of Scientific and Technical Information (OSTI.GOV)
Hembree, Charles E.; Mar, Alan; Robertson, Perry J.
2015-09-01
Typically, transistors are modeled by the application of calibrated nominal and range models. These models consists of differing parameter values that describe the location and the upper and lower limits of a distribution of some transistor characteristic such as current capacity. Correspond- ingly, when using this approach, high degrees of accuracy of the transistor models are not expected since the set of models is a surrogate for a statistical description of the devices. The use of these types of models describes expected performances considering the extremes of process or transistor deviations. In contrast, circuits that have very stringent accuracy requirementsmore » require modeling techniques with higher accuracy. Since these accurate models have low error in transistor descriptions, these models can be used to describe part to part variations as well as an accurate description of a single circuit instance. Thus, models that meet these stipulations also enable the calculation of quantifi- cation of margins with respect to a functional threshold and uncertainties in these margins. Given this need, new model high accuracy calibration techniques for bipolar junction transis- tors have been developed and are described in this report.« less
Kappa and Rater Accuracy: Paradigms and Parameters
ERIC Educational Resources Information Center
Conger, Anthony J.
2017-01-01
Drawing parallels to classical test theory, this article clarifies the difference between rater accuracy and reliability and demonstrates how category marginal frequencies affect rater agreement and Cohen's kappa. Category assignment paradigms are developed: comparing raters to a standard (index) versus comparing two raters to one another…
NASA Astrophysics Data System (ADS)
Jiang, Li; Xuan, Jianping; Shi, Tielin
2013-12-01
Generally, the vibration signals of faulty machinery are non-stationary and nonlinear under complicated operating conditions. Therefore, it is a big challenge for machinery fault diagnosis to extract optimal features for improving classification accuracy. This paper proposes semi-supervised kernel Marginal Fisher analysis (SSKMFA) for feature extraction, which can discover the intrinsic manifold structure of dataset, and simultaneously consider the intra-class compactness and the inter-class separability. Based on SSKMFA, a novel approach to fault diagnosis is put forward and applied to fault recognition of rolling bearings. SSKMFA directly extracts the low-dimensional characteristics from the raw high-dimensional vibration signals, by exploiting the inherent manifold structure of both labeled and unlabeled samples. Subsequently, the optimal low-dimensional features are fed into the simplest K-nearest neighbor (KNN) classifier to recognize different fault categories and severities of bearings. The experimental results demonstrate that the proposed approach improves the fault recognition performance and outperforms the other four feature extraction methods.
Hypersonic vehicle control law development using H infinity and mu-synthesis
NASA Technical Reports Server (NTRS)
Gregory, Irene M.; Chowdhry, Rajiv S.; Mcminn, John D.; Shaughnessy, John D.
1992-01-01
Applicability and effectiveness of robust control techniques to a single-stage-to-orbit (SSTO) airbreathing hypersonic vehicle on an ascent accelerating path and their effectiveness are explored in this paper. An SSTO control system design problem, requiring high accuracy tracking of velocity and altitude commands while limiting angle of attack oscillations, minimizing control power usage and stabilizing the vehicle all in the presence of atmospheric turbulence and uncertainty in the system, was formulated to compare results of the control designs using H infinity and mu-synthesis procedures. The math model, an integrated flight/propulsion dynamic model of a conical accelerator class vehicle, was linearized as the vehicle accelerated through Mach 8. Controller analysis was conducted using the singular value technique and the mu-analysis approach. Analysis results were obtained in both the frequency and the time domains. The results clearly demonstrate the inherent advantages of the structured singular value framework for this class of problems. Since payload performance margins are so critical for the SSTO mission, it is crucial that adequate stability margins be provided without sacrificing any payload mass.
In vitro marginal fit of three all-ceramic crown systems.
Yeo, In-Sung; Yang, Jae-Ho; Lee, Jai-Bong
2003-11-01
Studies on marginal discrepancies of single restorations using various systems and materials have resulted in statistical inferences that are ambiguous because of small sample sizes and limited numbers of measurements per specimen. The purpose of this study was to compare the marginal adaptation of single anterior restorations made using different systems. The in vitro marginal discrepancies of 3 different all-ceramic crown systems (Celay In-Ceram, conventional In-Ceram, and IPS Empress 2 layering technique), and a control group of metal ceramic restorations were evaluated and compared by measuring the gap dimension between the crowns and the prepared tooth at the marginal opening. The crowns were made for 1 extracted maxillary central incisor prepared with a 1-mm shoulder margin and 6-degree tapered walls by milling. Thirty crowns per system were fabricated. Crown measurements were recorded with an optical microscope, with an accuracy of +/-0.1 microm, at 50 points spaced approximately 400 microm along the circumferential margin. The criterion of 120 microm was used as the maximum clinically acceptable marginal gap. Mean gap dimensions and standard deviations were calculated for marginal opening. The data were analyzed with a 1-way analysis of variance (alpha=.05). Mean gap dimensions and standard deviations at the marginal opening for the incisor crowns were 87 +/- 34 microm for control, 83 +/- 33 microm for Celay In-Ceram, 112 +/- 55 microm for conventional In-Ceram, and 46 +/- 16 microm for the IPS Empress 2 layering technique. Significant differences were found among the crown groups (P<.05). Compared with the control group, the IPS Empress 2 group had significantly smaller marginal discrepancies (P<.05), and the conventional In-Ceram group exhibited significantly greater marginal discrepancies (P<.05). There was no significant difference between the Celay In-Ceram and the control group. Within the limitations of this study, the marginal discrepancies were all within the clinically acceptable standard set at 120 microm. However, the IPS Empress 2 system showed the smallest and most homogeneous gap dimension, whereas the conventional In-Ceram system presented the largest and more variable gap dimension compared with the metal ceramic (control) restoration.
Layfield, Eleanor M; Schmidt, Robert L; Esebua, Magda; Layfield, Lester J
2018-06-01
Frozen section is routinely used for intraoperative margin evaluation in carcinomas of the head and neck. We studied a series of frozen sections performed for margin status of head and neck tumors to determine diagnostic accuracy. All frozen sections for margin control of squamous carcinomas of the head and neck were studied from a 66 month period. Frozen and permanent section diagnoses were classified as negative or malignant. Correlation of diagnoses was performed to determine accuracy. One thousand seven hundred and ninety-six pairs of frozen section and corresponding permanent section diagnoses were obtained. Discordances were found in 55 (3.1%) pairs. In 35 pairs (1.9%), frozen section was reported as benign, but permanent sections disclosed carcinoma. In 21 cases, the discrepancy was due to sampling and in the remaining cases it was an interpretive error. In 20 cases (1.1%), frozen section was malignant, but the permanent section was interpreted as negative. Frozen section is an accurate method for evaluation of operative margins for head and neck carcinomas with concordance between frozen and permanent results of 97%. Most errors are false negative results with the majority of these being due to sampling issues.
Zimmermann, Moritz; Valcanaia, Andre; Neiva, Gisele; Mehl, Albert; Fasbinder, Dennis
2018-03-06
A wide variety of CAD/CAM materials are available for single-tooth restorations. CAD/CAM material characteristics are different and may influence CAM fabrication accuracy. There is no study investigating the influence of different CAD/CAM materials on the final fit of the restoration. The aim of this study was to evaluate the fit of endocrowns fabricated from different CAD/CAM materials using a new 3D evaluation method with an intraoral scanning system. The null hypothesis was that there are no significant differences for the fitting accuracy of different CAD/CAM materials. Preparation for an endocrown was performed on a maxillary right first molar on a typodont, and restorations were fabricated with a chairside CAD/CAM system (CEREC Omnicam, MCXL). Three groups using three different CAD/CAM materials were established (each n = 10): zirconia-reinforced lithium silicate ceramic (Celtra Duo; CD), leucite-reinforced silicate ceramic (Empress CAD; EM), resin nanoceramic (Lava Ultimate; LU). A 3D digital measurement technique (OraCheck, Cyfex AG) using an intraoral scanner (CEREC Omnicam) was used to measure the difference in fit between the three materials for a master endocrown preparation. The preparation scan and the endocrown fit scan were matched with special difference analysis software OraCheck. Three areas were selected for fitting accuracy measurements: margin (MA), axial (AX), occlusal (OC). Statistical analysis was performed using 80% percentile, one-way ANOVA, and post-hoc Scheffé test. Significance level was set to p = 0.05. Results varied from best 88.9 ± 7.7 μm for marginal fit of resin nanoceramic restorations (LU_MA) to worst 182.3 ± 24.0 μm for occlusal fit of zirconia-reinforced lithium silicate restorations (CD_OC). Statistically significant differences were found both within and among the test groups. Group CD performed statistically significantly different from group LU for marginal fit (MA) and axial fit (AX) (p < 0.05). For occlusal fit (OC), no statistically significant differences were found within all three test groups (p > 0.05). Deviation pattern for differences was visually analyzed with a color-coded scheme for each restoration. Statistically significant differences were found for different CAD/CAM materials if the CAM procedure was identical. Within the limitations of this study, the choice of CAD/CAM material may influence the fitting accuracy of CAD/CAM-fabricated restorations. © 2018 by the American College of Prosthodontists.
NASA Astrophysics Data System (ADS)
Brachtel, Elena F.; Johnson, Nicole B.; Huck, Amelia E.; Rice-Stitt, Travis L.; Vangel, Mark G.; Smith, Barbara L.; Tearney, Guillermo J.; Kang, DongKyun
2016-03-01
Unacceptably large percentage (20-40%) of breast cancer lumpectomy patients are required to undergo multiple surgeries when positive margins are found upon post-operative histologic assessment. If the margin status can be determined during surgery, surgeon can resect additional tissues to achieve tumor-free margin, which will reduce the need for additional surgeries. Spectrally encoded confocal microscopy (SECM) is a high-speed reflectance confocal microscopy technology that has a potential to image the entire surgical margin within a short procedural time. Previously, SECM was shown to rapidly image a large area (10 mm by 10 mm) of human esophageal tissue within a short procedural time (15 seconds). When used in lumpectomy, SECM will be able to image the entire margin surface of ~30 cm2 in around 7.5 minutes. SECM images will then be used to determine margin status intra-operatively. In this paper, we present results from a study of testing accuracy of SECM for diagnosing malignant breast tissues. We have imaged freshly-excised breast specimens (N=46) with SECM. SECM images clearly visualized histomorphologic features associated with normal/benign and malignant breast tissues in a similar manner to histologic images. Diagnostic accuracy was tested by comparing SECM diagnoses made by three junior pathologists with corresponding histologic diagnoses made by a senior pathologist. SECM sensitivity and specificity were high, 0.91 and 0.93, respectively. Intra-observer agreement and inter-observer agreement were also high, 0.87 and 0.84, respectively. Results from this study showed that SECM has a potential to accurately determine margin status during breast cancer lumpectomy.
Jei, J Brintha; Mohan, Jayashree
2014-03-01
The periodontal health of abutment teeth and the durability of fixed partial denture depends on the marginal adaptation of the prosthesis. Any discrepancy in the marginal area leads to dissolution of luting agent and plaque accumulation. This study was done with the aim of evaluating the accuracy of marginal fit of four unit crown and bridge made up of Ni-Cr and Cr-Co alloys under induction and centrifugal casting. They were compared to cast fixed partial denture (FPD) and soldered FPD. For the purpose of this study a metal model was fabricated. A total of 40 samples (4-unit crown and bridge) were prepared in which 20 Cr-Co samples and 20 Ni-Cr samples were fabricated. Within these 20 samples of each group 10 samples were prepared by induction casting technique and other 10 samples with centrifugal casting technique. The cast FPD samples obtained were seated on the model and the samples were then measured with travelling microscope having precision of 0.001 cm. Sectioning of samples was done between the two pontics and measurements were made, then the soldering was made with torch soldering unit. The marginal discrepancy of soldered samples was measured and all findings were statistically analysed. The results revealed minimal marginal discrepancy with Cr-Co samples when compared to Ni-Cr samples done under induction casting technique. When compared to cast FPD samples, the soldered group showed reduced marginal discrepancy.
NASA Astrophysics Data System (ADS)
Kho, Esther; de Boer, Lisanne L.; Van de Vijver, Koen K.; Sterenborg, Henricus J. C. M.; Ruers, Theo J. M.
2017-02-01
Worldwide, up to 40% of the breast conserving surgeries require additional operations due to positive resection margins. We propose to reduce this percentage by using hyperspectral imaging for resection margin assessment during surgery. Spectral hypercubes were collected from 26 freshly excised breast specimens with a pushbroom camera (900-1700nm). Computer simulations of the penetration depth in breast tissue suggest a strong variation in sampling depth ( 0.5-10 mm) over this wavelength range. This was confirmed with a breast tissue mimicking phantom study. Smaller penetration depths are observed in wavelength regions with high water and/or fat absorption. Consequently, tissue classification based on spectral analysis over the whole wavelength range becomes complicated. This is especially a problem in highly inhomogeneous human tissue. We developed a method, called derivative imaging, which allows accurate tissue analysis, without the impediment of dissimilar sampling volumes. A few assumptions were made based on previous research. First, the spectra acquired with our camera from breast tissue are mainly shaped by fat and water absorption. Second, tumor tissue contains less fat and more water than healthy tissue. Third, scattering slopes of different tissue types are assumed to be alike. In derivative imaging, the derivatives are calculated of wavelengths a few nanometers apart; ensuring similar penetration depths. The wavelength choice determines the accuracy of the method and the resolution. Preliminary results on 3 breast specimens indicate a classification accuracy of 93% when using wavelength regions characterized by water and fat absorption. The sampling depths at these regions are 1mm and 5mm.
Simon, Anne-Laure; Lugade, Vipul; Bernhardt, Kathie; Larson, A Noelle; Kaufman, Kenton
2017-06-01
Daily living activities are dynamic, requiring spinal motion through space. Current assessment of spinal deformities is based on static measurements from full-spine standing radiographs. Tools to assess dynamic stability during gait might be useful to enhance the standard evaluation. The aim of this study was to evaluate gait dynamic imbalance in patients with spinal deformity using the dynamic stability margin (DSM). Twelve normal subjects and 17 patients with spinal deformity were prospectively recruited. A kinematic 3D gait analysis was performed for the control group (CG) and the spinal deformity group (SDG). The DSM (distance between the extrapolated center of mass and the base of support) and time-distance parameters were calculated for the right and left side during gait. The relationship between DSM and step length was assessed using three variables: gait stability, symmetry, and consistency. Variables' accuracy was validated by a discriminant analysis. Patients with spinal deformity exhibited gait instability according to the DSM (0.25m versus 0.31m) with decreased velocity (1.1ms -1 versus 1.3ms -1 ) and decreased step length (0.32m versus 0.38m). According to the discriminant analysis, gait stability was the more accurate variable (area under the curve AUC=0.98) followed by gait symmetry and consistency. However, gait consistency showed 100% of specificity, sensitivity, and accuracy of precision. The DSM showed that patients with spinal malalignment exhibit decreased gait stability, symmetry, and consistency besides gait time-distance parameter changes. Additional work is required to determine how to apply the DSM for preoperative and postoperative spinal deformity management. Copyright © 2017. Published by Elsevier B.V.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Xu Huijun; Gordon, J. James; Siebers, Jeffrey V.
2011-02-15
Purpose: A dosimetric margin (DM) is the margin in a specified direction between a structure and a specified isodose surface, corresponding to a prescription or tolerance dose. The dosimetric margin distribution (DMD) is the distribution of DMs over all directions. Given a geometric uncertainty model, representing inter- or intrafraction setup uncertainties or internal organ motion, the DMD can be used to calculate coverage Q, which is the probability that a realized target or organ-at-risk (OAR) dose metric D{sub v} exceeds the corresponding prescription or tolerance dose. Postplanning coverage evaluation quantifies the percentage of uncertainties for which target and OAR structuresmore » meet their intended dose constraints. The goal of the present work is to evaluate coverage probabilities for 28 prostate treatment plans to determine DMD sampling parameters that ensure adequate accuracy for postplanning coverage estimates. Methods: Normally distributed interfraction setup uncertainties were applied to 28 plans for localized prostate cancer, with prescribed dose of 79.2 Gy and 10 mm clinical target volume to planning target volume (CTV-to-PTV) margins. Using angular or isotropic sampling techniques, dosimetric margins were determined for the CTV, bladder and rectum, assuming shift invariance of the dose distribution. For angular sampling, DMDs were sampled at fixed angular intervals {omega} (e.g., {omega}=1 deg., 2 deg., 5 deg., 10 deg., 20 deg.). Isotropic samples were uniformly distributed on the unit sphere resulting in variable angular increments, but were calculated for the same number of sampling directions as angular DMDs, and accordingly characterized by the effective angular increment {omega}{sub eff}. In each direction, the DM was calculated by moving the structure in radial steps of size {delta}(=0.1,0.2,0.5,1 mm) until the specified isodose was crossed. Coverage estimation accuracy {Delta}Q was quantified as a function of the sampling parameters {omega} or {omega}{sub eff} and {delta}. Results: The accuracy of coverage estimates depends on angular and radial DMD sampling parameters {omega} or {omega}{sub eff} and {delta}, as well as the employed sampling technique. Target |{Delta}Q|<1% and OAR |{Delta}Q|<3% can be achieved with sampling parameters {omega} or {omega}{sub eff}=20 deg., {delta}=1 mm. Better accuracy (target |{Delta}Q|<0.5% and OAR |{Delta}Q|<{approx}1%) can be achieved with {omega} or {omega}{sub eff}=10 deg., {delta}=0.5 mm. As the number of sampling points decreases, the isotropic sampling method maintains better accuracy than fixed angular sampling. Conclusions: Coverage estimates for post-planning evaluation are essential since coverage values of targets and OARs often differ from the values implied by the static margin-based plans. Finer sampling of the DMD enables more accurate assessment of the effect of geometric uncertainties on coverage estimates prior to treatment. DMD sampling with {omega} or {omega}{sub eff}=10 deg. and {delta}=0.5 mm should be adequate for planning purposes.« less
Xu, Huijun; Gordon, J James; Siebers, Jeffrey V
2011-02-01
A dosimetric margin (DM) is the margin in a specified direction between a structure and a specified isodose surface, corresponding to a prescription or tolerance dose. The dosimetric margin distribution (DMD) is the distribution of DMs over all directions. Given a geometric uncertainty model, representing inter- or intrafraction setup uncertainties or internal organ motion, the DMD can be used to calculate coverage Q, which is the probability that a realized target or organ-at-risk (OAR) dose metric D, exceeds the corresponding prescription or tolerance dose. Postplanning coverage evaluation quantifies the percentage of uncertainties for which target and OAR structures meet their intended dose constraints. The goal of the present work is to evaluate coverage probabilities for 28 prostate treatment plans to determine DMD sampling parameters that ensure adequate accuracy for postplanning coverage estimates. Normally distributed interfraction setup uncertainties were applied to 28 plans for localized prostate cancer, with prescribed dose of 79.2 Gy and 10 mm clinical target volume to planning target volume (CTV-to-PTV) margins. Using angular or isotropic sampling techniques, dosimetric margins were determined for the CTV, bladder and rectum, assuming shift invariance of the dose distribution. For angular sampling, DMDs were sampled at fixed angular intervals w (e.g., w = 1 degree, 2 degrees, 5 degrees, 10 degrees, 20 degrees). Isotropic samples were uniformly distributed on the unit sphere resulting in variable angular increments, but were calculated for the same number of sampling directions as angular DMDs, and accordingly characterized by the effective angular increment omega eff. In each direction, the DM was calculated by moving the structure in radial steps of size delta (=0.1, 0.2, 0.5, 1 mm) until the specified isodose was crossed. Coverage estimation accuracy deltaQ was quantified as a function of the sampling parameters omega or omega eff and delta. The accuracy of coverage estimates depends on angular and radial DMD sampling parameters omega or omega eff and delta, as well as the employed sampling technique. Target deltaQ/ < l% and OAR /deltaQ/ < 3% can be achieved with sampling parameters omega or omega eef = 20 degrees, delta =1 mm. Better accuracy (target /deltaQ < 0.5% and OAR /deltaQ < approximately 1%) can be achieved with omega or omega eff = 10 degrees, delta = 0.5 mm. As the number of sampling points decreases, the isotropic sampling method maintains better accuracy than fixed angular sampling. Coverage estimates for post-planning evaluation are essential since coverage values of targets and OARs often differ from the values implied by the static margin-based plans. Finer sampling of the DMD enables more accurate assessment of the effect of geometric uncertainties on coverage estimates prior to treatment. DMD sampling with omega or omega eff = 10 degrees and delta = 0.5 mm should be adequate for planning purposes.
Büchi, Dominik L; Ebler, Sabine; Hämmerle, Christoph H F; Sailer, Irena
2014-01-01
To test whether or not different types of CAD/CAM systems, processing zirconia in the densely and in the pre-sintered stage, lead to differences in the accuracy of 4-unit anterior fixed dental prosthesis (FDP) frameworks, and to evaluate the efficiency. 40 curved anterior 4-unit FDP frameworks were manufactured with four different CAD/CAM systems: DCS Precident (DCS) (control group), Cercon (DeguDent) (test group 1), Cerec InLab (Sirona) (test group 2), Kavo Everest (Kavo) (test group 3). The DCS System was chosen as the control group because the zirconia frameworks are processed in its densely sintered stage and there is no shrinkage of the zirconia during the manufacturing process. The initial fit of the frameworks was checked and adjusted to a subjectively similar level of accuracy by one dental technician, and the time taken for this was recorded. After cementation, the frameworks were embedded into resin and the abutment teeth were cut in mesiodistal and orobuccal directions in four specimens. The thickness of the cement gap was measured at 50× (internal adaptation) and 200× (marginal adaptation) magnification. The measurement of the accuracy was performed at four sites. Site 1: marginal adaptation, the marginal opening at the point of closest perpendicular approximation between the die and framework margin. Site 2: Internal adaptation at the chamfer. Site 3: Internal adaptation at the axial wall. Site 4: Internal adaptation in the occlusal area. The data were analyzed descriptively using the ANOVA and Bonferroni/ Dunn tests. The mean marginal adaptation (site 1) of the control group was 107 ± 26 μm; test group 1, 140 ± 26 μm; test group 2, 104 ± 40 μm; and test group 3, 95 ± 31 μm. Test group 1 showed a tendency to exhibit larger marginal gaps than the other groups, however, this difference was only significant when test groups 1 and 3 were compared (P = .0022; Bonferroni/Dunn test). Significantly more time was needed for the adjustment of the frameworks of test group 1 compared to the other test groups and the control group (21.1 min vs 3.8 min) (P < .0001; Bonferroni/Dunn test). For the adjustment of the frameworks of test groups 2 and 3, the same time was needed as for the frameworks of the control group. No differences of the framework accuracy resulting from the different CAM and CAD/CAM procedures were found; however, only after adjustment of the fit by an experienced dental technician. Hence, the influence of a manual correction of the fit was crucial, and the efforts differed for the tested systems. The CAM system led to lower initial accuracy of the frameworks than the CAD/CAM systems, which may be crucial for the dental laboratory. The stage of the zirconia materials used for the different CAD/CAM procedures, ie presintered or densely sintered, exhibited no influence.
A Directed Acyclic Graph-Large Margin Distribution Machine Model for Music Symbol Classification
Wen, Cuihong; Zhang, Jing; Rebelo, Ana; Cheng, Fanyong
2016-01-01
Optical Music Recognition (OMR) has received increasing attention in recent years. In this paper, we propose a classifier based on a new method named Directed Acyclic Graph-Large margin Distribution Machine (DAG-LDM). The DAG-LDM is an improvement of the Large margin Distribution Machine (LDM), which is a binary classifier that optimizes the margin distribution by maximizing the margin mean and minimizing the margin variance simultaneously. We modify the LDM to the DAG-LDM to solve the multi-class music symbol classification problem. Tests are conducted on more than 10000 music symbol images, obtained from handwritten and printed images of music scores. The proposed method provides superior classification capability and achieves much higher classification accuracy than the state-of-the-art algorithms such as Support Vector Machines (SVMs) and Neural Networks (NNs). PMID:26985826
A Directed Acyclic Graph-Large Margin Distribution Machine Model for Music Symbol Classification.
Wen, Cuihong; Zhang, Jing; Rebelo, Ana; Cheng, Fanyong
2016-01-01
Optical Music Recognition (OMR) has received increasing attention in recent years. In this paper, we propose a classifier based on a new method named Directed Acyclic Graph-Large margin Distribution Machine (DAG-LDM). The DAG-LDM is an improvement of the Large margin Distribution Machine (LDM), which is a binary classifier that optimizes the margin distribution by maximizing the margin mean and minimizing the margin variance simultaneously. We modify the LDM to the DAG-LDM to solve the multi-class music symbol classification problem. Tests are conducted on more than 10000 music symbol images, obtained from handwritten and printed images of music scores. The proposed method provides superior classification capability and achieves much higher classification accuracy than the state-of-the-art algorithms such as Support Vector Machines (SVMs) and Neural Networks (NNs).
Influence of polyurethane resin dies on the fit and adaptation of full veneer crowns.
Lillywhite, Graeme R R; Vohra, Fahim
2015-01-01
Polyurethane resin is a possible alternative to type IV dental stone for fabrication of indirect restorations however its dimensional accuracy is questionable. The aim was to investigate the dimensional accuracy of silica filled polyurethane resin die material by evaluating the marginal fit and adaptation of indirect gold castings. Experimental, in vitro study. Totally 40 copper plated replicas of a nickel chrome master die analogous to a veneer gold crown preparation were made and impressions recorded using polyvinylsiloxane material. Twenty impressions were poured in type IV dental stone (control group (Vel-mix, Kerr, UK) and the remaining (n = 20) in silica filled polyurethane die material (test group) (Alpha Die MF, CA, USA). Gold castings were fabricated for each die using standardized techniques. The castings were seated on their respective copper plated dies, embedded in resin and sectioned. The specimens were analyzed by measuring marginal opening and the area beneath the casting at a ×63 magnification and using image analysis software. Data were analyzed using a Student's t-test. No significant difference was observed between the experimental groups (P > 0.05). The mean marginal opening for type IV, dental stone and polyurethane resin, was 57 ± 22.6 μm and 63.47 ± 27.1 μm, respectively. Stone displayed a smaller area beneath the casting (31581 ± 16297 μm 2 ) as compared to polyurethane resin (35003 ± 23039 μm 2 ). The fit and adaptation of indirect gold castings made on polyurethane and type IV dental stone dies were comparable.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Mori, Shinichiro, E-mail: shinshin@nirs.go.jp; Karube, Masataka; Shirai, Toshiyuki
Purpose: Having implemented amplitude-based respiratory gating for scanned carbon-ion beam therapy, we sought to evaluate its effect on positional accuracy and throughput. Methods and Materials: A total of 10 patients with tumors of the lung and liver participated in the first clinical trials at our center. Treatment planning was conducted with 4-dimensional computed tomography (4DCT) under free-breathing conditions. The planning target volume (PTV) was calculated by adding a 2- to 3-mm setup margin outside the clinical target volume (CTV) within the gating window. The treatment beam was on when the CTV was within the PTV. Tumor position was detected inmore » real time with a markerless tumor tracking system using paired x-ray fluoroscopic imaging units. Results: The patient setup error (mean ± SD) was 1.1 ± 1.2 mm/0.6 ± 0.4°. The mean internal gating accuracy (95% confidence interval [CI]) was 0.5 mm. If external gating had been applied to this treatment, the mean gating accuracy (95% CI) would have been 4.1 mm. The fluoroscopic radiation doses (mean ± SD) were 23.7 ± 21.8 mGy per beam and less than 487.5 mGy total throughout the treatment course. The setup, preparation, and irradiation times (mean ± SD) were 8.9 ± 8.2 min, 9.5 ± 4.6 min, and 4.0 ± 2.4 min, respectively. The treatment room occupation time was 36.7 ± 67.5 min. Conclusions: Internal gating had a much higher accuracy than external gating. By the addition of a setup margin of 2 to 3 mm, internal gating positional error was less than 2.2 mm at 95% CI.« less
Alqahtani, Fawaz
2017-01-01
The purpose of this study was to determine the effect of two extraoral computer-aided design (CAD) and computer-aided manufacturing (CAM) systems, in comparison with conventional techniques, on the marginal fit of monolithic CAD/CAM lithium disilicate ceramic crowns. This is an in vitro interventional study. The study was carried out at the Department of Prosthodontics, School of Dentistry, Prince Sattam Bin Abdul-Aziz University, Saudi Arabia, from December 2015 to April 2016. A marginal gap of 60 lithium disilicate crowns was evaluated by scanning electron microscopy. In total, 20 pressable lithium disilicate (IPS e.max Press [Ivoclar Vivadent]) ceramic crowns were fabricated using the conventional lost-wax technique as a control group. The experimental all-ceramic crowns were produced based on a scan stone model and milled using two extraoral CAD/CAM systems: the Cerec group was fabricated using the Cerec CAD/CAM system, and the Trios group was fabricated using Trios CAD and milled using Wieland Zenotec CAM. One-way analysis of variance (ANOVA) and the Scheffe post hoc test were used for statistical comparison of the groups (α=0.05). The mean (±standard deviation) of the marginal gap of each group was as follows: the Control group was 91.15 (±15.35) µm, the Cerec group was 111.07 (±6.33) µm, and the Trios group was 60.17 (±11.09) µm. One-way ANOVA and the Scheffe post hoc test showed a statistically significant difference in the marginal gap between all groups. It can be concluded from the current study that all-ceramic crowns, fabricated using the CAD/CAM system, show a marginal accuracy that is acceptable in clinical environments. The Trios CAD group displayed the smallest marginal gap.
Face recognition using total margin-based adaptive fuzzy support vector machines.
Liu, Yi-Hung; Chen, Yen-Ting
2007-01-01
This paper presents a new classifier called total margin-based adaptive fuzzy support vector machines (TAF-SVM) that deals with several problems that may occur in support vector machines (SVMs) when applied to the face recognition. The proposed TAF-SVM not only solves the overfitting problem resulted from the outlier with the approach of fuzzification of the penalty, but also corrects the skew of the optimal separating hyperplane due to the very imbalanced data sets by using different cost algorithm. In addition, by introducing the total margin algorithm to replace the conventional soft margin algorithm, a lower generalization error bound can be obtained. Those three functions are embodied into the traditional SVM so that the TAF-SVM is proposed and reformulated in both linear and nonlinear cases. By using two databases, the Chung Yuan Christian University (CYCU) multiview and the facial recognition technology (FERET) face databases, and using the kernel Fisher's discriminant analysis (KFDA) algorithm to extract discriminating face features, experimental results show that the proposed TAF-SVM is superior to SVM in terms of the face-recognition accuracy. The results also indicate that the proposed TAF-SVM can achieve smaller error variances than SVM over a number of tests such that better recognition stability can be obtained.
Abe, M; Kiryu, T; Sonoda, K; Kashiki, Y
2011-11-01
The aim of this study was to evaluate the accuracy of a magnetic resonance imaging (MRI) marking technique with a drape-type thermoplastic shell for planning breast-conserving surgery (BCS). A prospective review was performed on 35 consecutive patients who underwent MRI in the supine position and used the specified MRI marking technique. Eleven cases underwent pre-operative chemotherapy and 24 cases did not. After immobilizing the breast mound with a drape-type thermoplastic shell, patients underwent MRI, and the location of the lesion was marked on the shell. Resection lines were dyed blue by indigo carmine, which was pushed through the pores of the shell. Specimens obtained during BCS were sliced into 5-mm contiguous sections, and the margin was assessed for each specimen. Cancer foci less than 5 mm from the margin were classified as positive. Of 35 patients, 33 were included in the analysis; 2 were excluded due to a lack of effect of pre-operative chemotherapy. Of these 33 patients, 25 (75.8%) had negative margins and 7 (21.2%) had positive margins. Our MRI marking technique may be useful for evaluating the extent of tumors that were determined by MRI alone. Long-term outcomes of this technique should be evaluated further. Copyright © 2011 Elsevier Ltd. All rights reserved.
van Rijn, Peter W; Ali, Usama S
2017-05-01
We compare three modelling frameworks for accuracy and speed of item responses in the context of adaptive testing. The first framework is based on modelling scores that result from a scoring rule that incorporates both accuracy and speed. The second framework is the hierarchical modelling approach developed by van der Linden (2007, Psychometrika, 72, 287) in which a regular item response model is specified for accuracy and a log-normal model for speed. The third framework is the diffusion framework in which the response is assumed to be the result of a Wiener process. Although the three frameworks differ in the relation between accuracy and speed, one commonality is that the marginal model for accuracy can be simplified to the two-parameter logistic model. We discuss both conditional and marginal estimation of model parameters. Models from all three frameworks were fitted to data from a mathematics and spelling test. Furthermore, we applied a linear and adaptive testing mode to the data off-line in order to determine differences between modelling frameworks. It was found that a model from the scoring rule framework outperformed a hierarchical model in terms of model-based reliability, but the results were mixed with respect to correlations with external measures. © 2017 The British Psychological Society.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Laaksomaa, Marko, E-mail: marko.laaksomaa@pshp.fi; Kapanen, Mika; Department of Medical Physics, Tampere University Hospital
We evaluated adequate setup margins for the radiotherapy (RT) of pelvic tumors based on overall position errors of bony landmarks. We also estimated the difference in setup accuracy between the male and female patients. Finally, we compared the patient rotation for 2 immobilization devices. The study cohort included consecutive 64 male and 64 female patients. Altogether, 1794 orthogonal setup images were analyzed. Observer-related deviation in image matching and the effect of patient rotation were explicitly determined. Overall systematic and random errors were calculated in 3 orthogonal directions. Anisotropic setup margins were evaluated based on residual errors after weekly image guidance.more » The van Herk formula was used to calculate the margins. Overall, 100 patients were immobilized with a house-made device. The patient rotation was compared against 28 patients immobilized with CIVCO's Kneefix and Feetfix. We found that the usually applied isotropic setup margin of 8 mm covered all the uncertainties related to patient setup for most RT treatments of the pelvis. However, margins of even 10.3 mm were needed for the female patients with very large pelvic target volumes centered either in the symphysis or in the sacrum containing both of these structures. This was because the effect of rotation (p ≤ 0.02) and the observer variation in image matching (p ≤ 0.04) were significantly larger for the female patients than for the male patients. Even with daily image guidance, the required margins remained larger for the women. Patient rotations were largest about the lateral axes. The difference between the required margins was only 1 mm for the 2 immobilization devices. The largest component of overall systematic position error came from patient rotation. This emphasizes the need for rotation correction. Overall, larger position errors and setup margins were observed for the female patients with pelvic cancer than for the male patients.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Calvo Ortega, Juan Francisco, E-mail: jfcdrr@yahoo.es; Wunderink, Wouter; Delgado, David
The aim of this study is to evaluate the setup margins from the clinical target volume (CTV) to planning target volume (PTV) for cranial stereotactic radiosurgery (SRS) treatments guided by cone beam computed tomography (CBCT). We designed an end-to-end (E2E) test using a skull phantom with an embedded 6mm tungsten ball (target). A noncoplanar plan was computed (E2E plan) to irradiate the target. The CBCT-guided positioning of the skull phantom on the linac was performed. Megavoltage portal images were acquired after 15 independent deliveries of the E2E plan. The displacement 2-dimensional (2D) vector between the centers of the square fieldmore » and the ball target on each portal image was used to quantify the isocenter accuracy. Geometrical margins on each patient's direction (left-right or LR, anterior-posterior or AP, superior-inferior or SI) were calculated. Dosimetric validation of the margins was performed in 5 real SRS cases: 3-dimesional (3D) isocenter deviations were mimicked, and changes in CTV dose coverage and organs-at-risk (OARs) dosage were analyzed. The CTV-PTV margins of 1.1 mm in LR direction, and 0.7 mm in AP and SI directions were derived from the E2E tests. The dosimetric analysis revealed that a 1-mm uniform margin was sufficient to ensure the CTV dose coverage, without compromising the OAR dose tolerances. The effect of isocenter uncertainty has been estimated to be 1 mm in our CBCT-guided SRS approach.« less
Garbarino, John R.; Taylor, Howard E.
1987-01-01
Inductively coupled plasma mass spectrometry is employed in the determination of Ni, Cu, Sr, Cd, Ba, Ti, and Pb in nonsaline, natural water samples by stable isotope dilution analysis. Hydrologic samples were directly analyzed without any unusual pretreatment. Interference effects related to overlapping isobars, formation of metal oxide and multiply charged ions, and matrix composition were identified and suitable methods of correction evaluated. A comparability study snowed that single-element isotope dilution analysis was only marginally better than sequential multielement isotope dilution analysis. Accuracy and precision of the single-element method were determined on the basis of results obtained for standard reference materials. The instrumental technique was shown to be ideally suited for programs associated with certification of standard reference materials.
Papadiochou, Sofia; Pissiotis, Argirios L
2018-04-01
The comparative assessment of computer-aided design and computer-aided manufacturing (CAD-CAM) technology and other fabrication techniques pertaining to marginal adaptation should be documented. Limited evidence exists on the effect of restorative material on the performance of a CAD-CAM system relative to marginal adaptation. The purpose of this systematic review was to investigate whether the marginal adaptation of CAD-CAM single crowns, fixed dental prostheses, and implant-retained fixed dental prostheses or their infrastructures differs from that obtained by other fabrication techniques using a similar restorative material and whether it depends on the type of restorative material. An electronic search of English-language literature published between January 1, 2000, and June 30, 2016, was conducted of the Medline/PubMed database. Of the 55 included comparative studies, 28 compared CAD-CAM technology with conventional fabrication techniques, 12 contrasted CAD-CAM technology and copy milling, 4 compared CAD-CAM milling with direct metal laser sintering (DMLS), and 22 investigated the performance of a CAD-CAM system regarding marginal adaptation in restorations/infrastructures produced with different restorative materials. Most of the CAD-CAM restorations/infrastructures were within the clinically acceptable marginal discrepancy (MD) range. The performance of a CAD-CAM system relative to marginal adaptation is influenced by the restorative material. Compared with CAD-CAM, most of the heat-pressed lithium disilicate crowns displayed equal or smaller MD values. Slip-casting crowns exhibited similar or better marginal accuracy than those fabricated with CAD-CAM. Cobalt-chromium and titanium implant infrastructures produced using a CAD-CAM system elicited smaller MD values than zirconia. The majority of cobalt-chromium restorations/infrastructures produced by DMLS displayed better marginal accuracy than those fabricated with the casting technique. Compared with copy milling, the majority of zirconia restorations/infrastructures produced by CAD-CAM milling exhibited better marginal adaptation. No clear conclusions can be drawn about the superiority of CAD-CAM milling over the casting technique and DMLS regarding marginal adaptation. Copyright © 2017 Editorial Council for the Journal of Prosthetic Dentistry. Published by Elsevier Inc. All rights reserved.
Liang, Shanshan; Yuan, Fusong; Luo, Xu; Yu, Zhuoren; Tang, Zhihui
2018-04-05
Marginal discrepancy is key to evaluating the accuracy of fixed dental prostheses. An improved method of evaluating marginal discrepancy is needed. The purpose of this in vitro study was to evaluate the absolute marginal discrepancy of ceramic crowns fabricated using conventional and digital methods with a digital method for the quantitative evaluation of absolute marginal discrepancy. The novel method was based on 3-dimensional scanning, iterative closest point registration techniques, and reverse engineering theory. Six standard tooth preparations for the right maxillary central incisor, right maxillary second premolar, right maxillary second molar, left mandibular lateral incisor, left mandibular first premolar, and left mandibular first molar were selected. Ten conventional ceramic crowns and 10 CEREC crowns were fabricated for each tooth preparation. A dental cast scanner was used to obtain 3-dimensional data of the preparations and ceramic crowns, and the data were compared with the "virtual seating" iterative closest point technique. Reverse engineering software used edge sharpening and other functional modules to extract the margins of the preparations and crowns. Finally, quantitative evaluation of the absolute marginal discrepancy of the ceramic crowns was obtained from the 2-dimensional cross-sectional straight-line distance between points on the margin of the ceramic crowns and the standard preparations based on the circumferential function module along the long axis. The absolute marginal discrepancy of the ceramic crowns fabricated using conventional methods was 115 ±15.2 μm, and 110 ±14.3 μm for those fabricated using the digital technique was. ANOVA showed no statistical difference between the 2 methods or among ceramic crowns for different teeth (P>.05). The digital quantitative evaluation method for the absolute marginal discrepancy of ceramic crowns was established. The evaluations determined that the absolute marginal discrepancies were within a clinically acceptable range. This method is acceptable for the digital evaluation of the accuracy of complete crowns. Copyright © 2017 Editorial Council for the Journal of Prosthetic Dentistry. Published by Elsevier Inc. All rights reserved.
Aerodynamic analysis of Pegasus - Computations vs reality
NASA Technical Reports Server (NTRS)
Mendenhall, Michael R.; Lesieutre, Daniel J.; Whittaker, C. H.; Curry, Robert E.; Moulton, Bryan
1993-01-01
Pegasus, a three-stage, air-launched, winged space booster was developed to provide fast and efficient commercial launch services for small satellites. The aerodynamic design and analysis of Pegasus was conducted without benefit of wind tunnel tests using only computational aerodynamic and fluid dynamic methods. Flight test data from the first two operational flights of Pegasus are now available, and they provide an opportunity to validate the accuracy of the predicted pre-flight aerodynamic characteristics. Comparisons of measured and predicted flight characteristics are presented and discussed. Results show that the computational methods provide reasonable aerodynamic design information with acceptable margins. Post-flight analyses illustrate certain areas in which improvements are desired.
Kioleoglou, Ioannis; Pissiotis, Argirios
2018-01-01
Background The purpose of this study was to evaluate the accuracy of fitting of an implant supported screw-retained bar made on definitive casts produced by 4 different dental stone products. Material and Methods The dental stones tested were QuickRock (Protechno), FujiRock (GC), Jade Stone (Whip Mix) and Moldasynt (Heraeus). Three external hexagon implants were placed in a polyoxymethylene block. Definitive impressions were made using monophase high viscosity polyvinylsiloxane in combination with custom trays. Then, definitive models from the different types of dental stones were fabricated. Three castable cylinders with a machined non-enganging base were cast and connected with a very small quantity of PMMA to a cast bar, which was used to verify the marginal discrepancies between the abutments and the prosthetic platforms of the implants. For that purpose special software and a camera mounted on an optical microscope were used. The gap was measured by taking 10 measurements on each abutment, after the Sheffield test was applied. Twelve definitive casts were fabricated for each gypsum product and 40 measurements were performed for each cast. Mean, minimum, and maximum values were calculated. The Shapiro-Wilk test of normality was performed. Mann-Whitney test (P<.06) was used for the statistical analysis of the measurements. Results The non-parametric Kruskal-Wallis test revealed a statistically significant effect of the stone factor on the marginal discrepancy for all Sheffield test combinations: 1. Abutment 2 when screw was fastened on abutment 1 (χ2=3, df=35.33, P<0.01), 2. Abutment 3 when the screw was fastened on abutment 1 (χ2=3, df=37.74, P<0.01), 3. Abutment 1 when the screw was fastened on abutment 3 (χ2=3, df=39.79, P<0.01), 4. Abutment 2 when the screw was fastened on abutment 3 (χ2=3, df=37.26, P<0.01). Conclusions A significant correlation exists between marginal discrepancy and different dental gypsum products used for the fabrication of definitive casts for implant supported bars. The smallest marginal discrepancy was noted on implant supported bars fabricated on definitive casts made by Type III mounting stone. The biggest marginal discrepancy was noted on implant supported bars fabricated on definitive casts made by Type V dental stone. The marginal discrepancies presented on implant supported bars fabricated on definitive casts made by two types of Type IV dental stone were not significantly different. Key words:Dental implant, passive fit, dental stones, marginal discrepancy. PMID:29721227
Walker, Luke; Chinnaiyan, Prakash; Forster, Kenneth
2008-01-01
We conducted a comprehensive evaluation of the clinical accuracy of an image‐guided frameless intracranial radiosurgery system. All links in the process chain were tested. Using healthy volunteers, we evaluated a novel method to prospectively quantify the range of target motion for optimal determination of the planning target volume (PTV) margin. The overall system isocentric accuracy was tested using a rigid anthropomorphic phantom containing a hidden target. Intrafraction motion was simulated in 5 healthy volunteers. Reinforced head‐and‐shoulders thermoplastic masks were used for immobilization. The subjects were placed in a treatment position for 15 minutes (the maximum expected time between repeated isocenter localizations) and the six‐degrees‐of‐freedom target displacements were recorded with high frequency by tracking infrared markers. The markers were placed on a customized piece of thermoplastic secured to the head independently of the immobilization mask. Additional data were collected with the subjects holding their breath, talking, and deliberately moving. As compared with fiducial matching, the automatic registration algorithm did not introduce clinically significant errors (<0.3 mm difference). The hidden target test confirmed overall system isocentric accuracy of ≤1 mm (total three‐dimensional displacement). The subjects exhibited various patterns and ranges of head motion during the mock treatment. The total displacement vector encompassing 95% of the positional points varied from 0.4 mm to 2.9 mm. Pre‐planning motion simulation with optical tracking was tested on volunteers and appears promising for determination of patient‐specific PTV margins. Further patient study is necessary and is planned. In the meantime, system accuracy is sufficient for confident clinical use with 3 mm PTV margins. PACS number: 87.53.Ly
Gopalan, Reji P; Nair, Vivek V; Harshakumar, K; Ravichandran, R; Lylajam, S; Viswambaran, Prasanth
2018-01-01
Different pattern materials do not produce copings with satisfactory, marginal accuracy when used on stone dies at varying time intervals. The purpose of this study was to evaluate and compare the vertical marginal accuracy of patterns formed from three materials, namely, thermoplastic resin, light cured wax and inlay casting wax at three-time intervals of 1, 12, and 24 h. A master die (zirconia abutment mimicking a prepared permanent maxillary central incisor) and metal sleeve (direct metal laser sintering crown #11) were fabricated. A total of 30 stone dies were obtained from the master die. Ten patterns were made each from the three materials and stored off the die at room temperature. The vertical marginal gaps were measured using digital microscope at 1, 12, and 24 h after reseating with gentle finger pressure. The results revealed a significant statistical difference in the marginal adaptation of three materials at all the three-time intervals. Light cured wax was found to be most accurate at all time intervals, followed by thermoplastic resin and inlay casting wax. Furthermore, there was a significant difference between all pairs of materials. The change in vertical marginal gap from 1 to 24 h between thermoplastic resin and light cured wax was not statistically significant. The marginal adaptation of all the three materials used, was well within the acceptable range of 25-70 μm. The resin pattern materials studied revealed significantly less dimensional change than inlay casting wax on storage at 1, 12, and 24 h time intervals. They may be employed in situations where high precision and delayed investing is expected.
Genealogical Working Distributions for Bayesian Model Testing with Phylogenetic Uncertainty
Baele, Guy; Lemey, Philippe; Suchard, Marc A.
2016-01-01
Marginal likelihood estimates to compare models using Bayes factors frequently accompany Bayesian phylogenetic inference. Approaches to estimate marginal likelihoods have garnered increased attention over the past decade. In particular, the introduction of path sampling (PS) and stepping-stone sampling (SS) into Bayesian phylogenetics has tremendously improved the accuracy of model selection. These sampling techniques are now used to evaluate complex evolutionary and population genetic models on empirical data sets, but considerable computational demands hamper their widespread adoption. Further, when very diffuse, but proper priors are specified for model parameters, numerical issues complicate the exploration of the priors, a necessary step in marginal likelihood estimation using PS or SS. To avoid such instabilities, generalized SS (GSS) has recently been proposed, introducing the concept of “working distributions” to facilitate—or shorten—the integration process that underlies marginal likelihood estimation. However, the need to fix the tree topology currently limits GSS in a coalescent-based framework. Here, we extend GSS by relaxing the fixed underlying tree topology assumption. To this purpose, we introduce a “working” distribution on the space of genealogies, which enables estimating marginal likelihoods while accommodating phylogenetic uncertainty. We propose two different “working” distributions that help GSS to outperform PS and SS in terms of accuracy when comparing demographic and evolutionary models applied to synthetic data and real-world examples. Further, we show that the use of very diffuse priors can lead to a considerable overestimation in marginal likelihood when using PS and SS, while still retrieving the correct marginal likelihood using both GSS approaches. The methods used in this article are available in BEAST, a powerful user-friendly software package to perform Bayesian evolutionary analyses. PMID:26526428
Marginal space learning for efficient detection of 2D/3D anatomical structures in medical images.
Zheng, Yefeng; Georgescu, Bogdan; Comaniciu, Dorin
2009-01-01
Recently, marginal space learning (MSL) was proposed as a generic approach for automatic detection of 3D anatomical structures in many medical imaging modalities [1]. To accurately localize a 3D object, we need to estimate nine pose parameters (three for position, three for orientation, and three for anisotropic scaling). Instead of exhaustively searching the original nine-dimensional pose parameter space, only low-dimensional marginal spaces are searched in MSL to improve the detection speed. In this paper, we apply MSL to 2D object detection and perform a thorough comparison between MSL and the alternative full space learning (FSL) approach. Experiments on left ventricle detection in 2D MRI images show MSL outperforms FSL in both speed and accuracy. In addition, we propose two novel techniques, constrained MSL and nonrigid MSL, to further improve the efficiency and accuracy. In many real applications, a strong correlation may exist among pose parameters in the same marginal spaces. For example, a large object may have large scaling values along all directions. Constrained MSL exploits this correlation for further speed-up. The original MSL only estimates the rigid transformation of an object in the image, therefore cannot accurately localize a nonrigid object under a large deformation. The proposed nonrigid MSL directly estimates the nonrigid deformation parameters to improve the localization accuracy. The comparison experiments on liver detection in 226 abdominal CT volumes demonstrate the effectiveness of the proposed methods. Our system takes less than a second to accurately detect the liver in a volume.
Near-infrared autofluorescence spectroscopy of in vivo soft tissue sarcomas
Nguyen, John Quan; Gowani, Zain; O'Connor, Maggie; Pence, Isaac; Nguyen, The-Quyen; Holt, Ginger; Mahadevan-Jansen, Anita
2016-01-01
Soft tissue sarcomas (STS) are a rare and heterogeneous group of malignant tumors that are often treated via surgical resection. Inadequate resection can lead to local recurrence and decreased survival rates. In this study, we investigate the hypothesis that near-infrared (NIR) autofluorescence can be utilized for tumor margin analysis by differentiating STS from the surrounding normal tissue. Intraoperative in vivo measurements were acquired from 30 patients undergoing STS resection and were characterized to differentiate between normal tissue and STS. Overall, normal muscle and fat were observed to have the highest and lowest autofluorescence intensities, respectively, with STS falling in between. With the exclusion of well-differentiated liposarcomas, the algorithm's accuracy for classifying muscle, fat, and STS was 93%, 92%, and 88%, respectively. These findings suggest that NIR autofluorescence spectroscopy has potential as a rapid and nondestructive surgical guidance tool that can inform surgeons of suspicious margins in need of immediate re-excision. PMID:26625035
The simulations of indirect-drive targets for ignition on megajoule lasers.
NASA Astrophysics Data System (ADS)
Lykov, Vladimir; Andreev, Eugene; Ardasheva, Ludmila; Avramenko, Michael; Chernyakov, Valerian; Chizhkov, Maxim; Karlykhanov, Nikalai; Kozmanov, Michael; Lebedev, Serge; Rykovanov, George; Seleznev, Vladimir; Sokolov, Lev; Timakova, Margaret; Shestakov, Alexander; Shushlebin, Aleksander
2013-10-01
The calculations were performed with use of radiation hydrodynamic codes developed in RFNC-VNIITF. The analysis of published calculations of indirect-drive targets to obtain ignition on NIF and LMJ lasers has shown that these targets have very low margins for ignition: according to 1D-ERA code calculations it could not be ignited under decreasing of thermonuclear reaction rate less than in 2 times.The purpose of new calculations is search of indirect-drive targets with the raised margins for ignition. The calculations of compression and thermonuclear burning of targets are carried out for conditions of X-ray flux asymmetry obtained in simulations of Rugby hohlraum that were performed with 2D-SINARA code. The requirements to accuracy of manufacturing and irradiation symmetry of targets were studied with use of 2D-TIGR-OMEGA-3T code. The necessity of performed researches is caused by the construction of magajoule laser in Russia.
Kalavathi, M; Sachin, Bhuvana; Prasanna, B G; Shreeharsha, T V; Praveen, B; Ragher, Mallikarjuna
2016-02-01
The thermal expansion of the investment can be restricted by the metal casting ring because the thermal expansion of the ring is less than that of the investment. The ringless casting procedure is in use in clinical dentistry, though there is little scientific data to support its use in fixed partial dentures. In this study, marginal discrepancy of castings produced with the ringless casting technique and the conventional technique using the metal rings were compared. A total of 30 wax patterns were fabricated directly on a metal die. Optical stereomicroscope was used to measure the marginal discrepancy between the metal die and wax patterns. A total of 15 castings were invested using Bellavest T phosphate-bonded investment with the ringless technique and 15 were invested with the same investment with a metal ring; 30 castings were produced using a nickel-chromium ceramo-metal alloy. The internal surface of the castings was not modified and seated with finger pressure. The vertical marginal discrepancy was measured using an optical stereomicroscope at a magnification of 100x. The data obtained were statistically analyzed using students t-test (paired t-test and unpaired t-test). The castings of the ringless technique provided less vertical marginal discrepancy (240.56 ± 45.81 μ) than the castings produced with the conventional metal ring technique (281.98± 53.05 μ). The difference was statistically significant. The ringless casting technique had produced better marginal accuracy compared with conventional casting technique. Ringless casting system can be used routinely for clinical purpose.
A comparative analysis of toluidine blue with frozen section in oral squamous cell carcinoma
2012-01-01
Background Surgical excision of the primary tumor with safe margins remains the mainstay of treatment for oral cavity squamous cell carcinoma (OSCC). The standard of care for assessment of intraoperative margins is frozen section histopathology. Unfortunately the facility is not available at most centers in limited resource countries. Toluidine blue, a metachromatic dye, has been well described in clinical identification of malignant and premalignant lesion in the oral cavity. Considering this we decided to explore intraoperative use of toluidine blue staining, in comparison with frozen sections, for the assessment of tumor-free margins. Methods After obtaining clearance from the in-house ethical review committee, a prospective study was conducted at Aga Khan University Hospital, Karachi, from August 15, 2009 to March 14, 2010. A sample of 56 consenting patients with biopsy-proven OSCC were included in the study, giving us 280 tumor margins. Margins were analyzed using toluidine blue staining and frozen section histopathology. A receiver operator curve (ROC) was then applied to compare assessment of margin status by toluidine blue and frozen section. Results Of the 280 examined margins 11 stained positive with toluidine blue, three were positive on frozen section biopsy, and three were positive on final histopathology. Toluidine blue staining had sensitivity and specificity of 100% and 97%, respectively. The diagnostic accuracy of toluidine blue was found to be 97.1% with a positive predictive value (PPV) of 27.2% and a negative predictive value (NPV) of 100%. Conclusions Toluidine blue can be used as an effective screening modality for the assessment of intraoperative margins in resource limited environments and reducing the number of frozen section biopsies performed. Further by providing real-time clinical information within minutes it can reduce indirect costs such as operating room time. It may also be used as an ad hoc for frozen section biopsies where frozen section facilities are available. PMID:22500814
Warrier, Satish K; Kong, Joseph Cherng; Guerra, Glen R; Chittleborough, Timothy J; Naik, Arun; Ramsay, Robert G; Lynch, A Craig; Heriot, Alexander G
2018-04-01
Rectal cancer outcomes have improved with the adoption of a multidisciplinary model of care. However, there is a spectrum of quality when viewed from a national perspective, as highlighted by the Consortium for Optimizing the Treatment of Rectal Cancer data on rectal cancer care in the United States. The aim of this study was to assess and identify predictors of circumferential resection margin involvement for rectal cancer across Australasia. A retrospective study from a prospectively maintained binational colorectal cancer database was interrogated. This study is based on a binational colorectal cancer audit database. Clinical information on all consecutive resected rectal cancer cases recorded in the registry from 2007 to 2016 was retrieved, collated, and analyzed. The primary outcome measure was positive circumferential resection margin, measured as a resection margin ≤1 mm. A total of 3367 patients were included, with 261 (7.5%) having a positive circumferential resection margin. After adjusting for hospital and surgeon volume, hierarchical logistic regression analysis identified a 6-variable model encompassing the independent predictors, including urgent operation, abdominoperineal resection, open technique, low rectal cancer, T3 to T4, and N1 to N2. The accuracy of the model was 92.3%, with an receiver operating characteristic of 0.783 (p < 0.0001). The quantitative risk associated with circumferential resection margin positivity ranged from <1% (no risk factors) to 43% (6 risk factors). This study was limited by the lack of recorded long-term outcomes associated with circumferential resection margin positivity. The rate of circumferential resection margin involvement in patients undergoing rectal cancer resection in Australasia is low and is influenced by a number of factors. Risk stratification of outcome is important with the increasing demand for publicly accessible quality data. See Video Abstract at http://links.lww.com/DCR/A512.
NASA Astrophysics Data System (ADS)
Gu, Wen; Zhu, Zhiwei; Zhu, Wu-Le; Lu, Leyao; To, Suet; Xiao, Gaobo
2018-05-01
An automatic identification method for obtaining the critical depth-of-cut (DoC) of brittle materials with nanometric accuracy and sub-nanometric uncertainty is proposed in this paper. With this method, a two-dimensional (2D) microscopic image of the taper cutting region is captured and further processed by image analysis to extract the margin of generated micro-cracks in the imaging plane. Meanwhile, an analytical model is formulated to describe the theoretical curve of the projected cutting points on the imaging plane with respect to a specified DoC during the whole cutting process. By adopting differential evolution algorithm-based minimization, the critical DoC can be identified by minimizing the deviation between the extracted margin and the theoretical curve. The proposed method is demonstrated through both numerical simulation and experimental analysis. Compared with conventional 2D- and 3D-microscopic-image-based methods, determination of the critical DoC in this study uses the envelope profile rather than the onset point of the generated cracks, providing a more objective approach with smaller uncertainty.
Atwal, Anita; McIntyre, Anne
2017-01-01
Introduction High quality guidance in home strategies is needed to enable older people to measure their home environment and become involved in the provision of assistive devices and to promote consistency among professionals. This study aims to investigate the reliability of such guidance and its ability to promote accuracy of results when measurements are taken by both older people and professionals. Method Twenty-five health professionals and 26 older people participated in a within-group design to test the accuracy of measurements taken (that is, person’s popliteal height, baths, toilets, beds, stairs and chairs). Data were analysed with descriptive analysis and the Wilcoxon test. The intra-rater reliability was assessed by correlating measurements taken at two different times with guidance use. Results The intra-rater reliability analysis revealed statistical significance (P < 0.05) for all measurements except for the bath internal width. The guidance enabled participants to take 90% of measurements that they were not able to complete otherwise, 80.55% of which lay within the acceptable suggested margin of variation. Accuracy was supported by the significant reduction in the standard deviation of the actual measurements and accuracy scores. Conclusion This evidence-based guidance can be used in its current format by older people and professionals to facilitate appropriate measurements. Yet, some users might need help from carers or specialists depending on their impairments. PMID:29386701
Spiliotopoulou, Georgia; Atwal, Anita; McIntyre, Anne
2018-01-01
High quality guidance in home strategies is needed to enable older people to measure their home environment and become involved in the provision of assistive devices and to promote consistency among professionals. This study aims to investigate the reliability of such guidance and its ability to promote accuracy of results when measurements are taken by both older people and professionals. Twenty-five health professionals and 26 older people participated in a within-group design to test the accuracy of measurements taken (that is, person's popliteal height, baths, toilets, beds, stairs and chairs). Data were analysed with descriptive analysis and the Wilcoxon test. The intra-rater reliability was assessed by correlating measurements taken at two different times with guidance use. The intra-rater reliability analysis revealed statistical significance ( P < 0.05) for all measurements except for the bath internal width. The guidance enabled participants to take 90% of measurements that they were not able to complete otherwise, 80.55% of which lay within the acceptable suggested margin of variation. Accuracy was supported by the significant reduction in the standard deviation of the actual measurements and accuracy scores. This evidence-based guidance can be used in its current format by older people and professionals to facilitate appropriate measurements. Yet, some users might need help from carers or specialists depending on their impairments.
Precise Absolute Astrometry from the VLBA Imaging and Polarimetry Survey at 5 GHz
NASA Technical Reports Server (NTRS)
Petrov, L.; Taylor, G. B.
2011-01-01
We present accurate positions for 857 sources derived from the astrometric analysis of 16 eleven-hour experiments from the Very Long Baseline Array imaging and polarimetry survey at 5 GHz (VIPS). Among the observed sources, positions of 430 objects were not previously determined at milliarcsecond-level accuracy. For 95% of the sources the uncertainty of their positions ranges from 0.3 to 0.9 mas, with a median value of 0.5 mas. This estimate of accuracy is substantiated by the comparison of positions of 386 sources that were previously observed in astrometric programs simultaneously at 2.3/8.6 GHz. Surprisingly, the ionosphere contribution to group delay was adequately modeled with the use of the total electron content maps derived from GPS observations and only marginally affected estimates of source coordinates.
Inter- and Intrafraction Uncertainty in Prostate Bed Image-Guided Radiotherapy
DOE Office of Scientific and Technical Information (OSTI.GOV)
Huang, Kitty; Palma, David A.; Department of Oncology, University of Western Ontario, London
2012-10-01
Purpose: The goals of this study were to measure inter- and intrafraction setup error and prostate bed motion (PBM) in patients undergoing post-prostatectomy image-guided radiotherapy (IGRT) and to propose appropriate population-based three-dimensional clinical target volume to planning target volume (CTV-PTV) margins in both non-IGRT and IGRT scenarios. Methods and Materials: In this prospective study, 14 patients underwent adjuvant or salvage radiotherapy to the prostate bed under image guidance using linac-based kilovoltage cone-beam CT (kV-CBCT). Inter- and intrafraction uncertainty/motion was assessed by offline analysis of three consecutive daily kV-CBCT images of each patient: (1) after initial setup to skin marks, (2)more » after correction for positional error/immediately before radiation treatment, and (3) immediately after treatment. Results: The magnitude of interfraction PBM was 2.1 mm, and intrafraction PBM was 0.4 mm. The maximum inter- and intrafraction prostate bed motion was primarily in the anterior-posterior direction. Margins of at least 3-5 mm with IGRT and 4-7 mm without IGRT (aligning to skin marks) will ensure 95% of the prescribed dose to the clinical target volume in 90% of patients. Conclusions: PBM is a predominant source of intrafraction error compared with setup error and has implications for appropriate PTV margins. Based on inter- and estimated intrafraction motion of the prostate bed using pre- and post-kV-CBCT images, CBCT IGRT to correct for day-to-day variances can potentially reduce CTV-PTV margins by 1-2 mm. CTV-PTV margins for prostate bed treatment in the IGRT and non-IGRT scenarios are proposed; however, in cases with more uncertainty of target delineation and image guidance accuracy, larger margins are recommended.« less
Cluster-based exposure variation analysis
2013-01-01
Background Static posture, repetitive movements and lack of physical variation are known risk factors for work-related musculoskeletal disorders, and thus needs to be properly assessed in occupational studies. The aims of this study were (i) to investigate the effectiveness of a conventional exposure variation analysis (EVA) in discriminating exposure time lines and (ii) to compare it with a new cluster-based method for analysis of exposure variation. Methods For this purpose, we simulated a repeated cyclic exposure varying within each cycle between “low” and “high” exposure levels in a “near” or “far” range, and with “low” or “high” velocities (exposure change rates). The duration of each cycle was also manipulated by selecting a “small” or “large” standard deviation of the cycle time. Theses parameters reflected three dimensions of exposure variation, i.e. range, frequency and temporal similarity. Each simulation trace included two realizations of 100 concatenated cycles with either low (ρ = 0.1), medium (ρ = 0.5) or high (ρ = 0.9) correlation between the realizations. These traces were analyzed by conventional EVA, and a novel cluster-based EVA (C-EVA). Principal component analysis (PCA) was applied on the marginal distributions of 1) the EVA of each of the realizations (univariate approach), 2) a combination of the EVA of both realizations (multivariate approach) and 3) C-EVA. The least number of principal components describing more than 90% of variability in each case was selected and the projection of marginal distributions along the selected principal component was calculated. A linear classifier was then applied to these projections to discriminate between the simulated exposure patterns, and the accuracy of classified realizations was determined. Results C-EVA classified exposures more correctly than univariate and multivariate EVA approaches; classification accuracy was 49%, 47% and 52% for EVA (univariate and multivariate), and C-EVA, respectively (p < 0.001). All three methods performed poorly in discriminating exposure patterns differing with respect to the variability in cycle time duration. Conclusion While C-EVA had a higher accuracy than conventional EVA, both failed to detect differences in temporal similarity. The data-driven optimality of data reduction and the capability of handling multiple exposure time lines in a single analysis are the advantages of the C-EVA. PMID:23557439
BRIEF REPORT: Screening Items to Identify Patients with Limited Health Literacy Skills
Wallace, Lorraine S; Rogers, Edwin S; Roskos, Steven E; Holiday, David B; Weiss, Barry D
2006-01-01
BACKGROUND Patients with limited literacy skills are routinely encountered in clinical practice, but they are not always identified by clinicians. OBJECTIVE To evaluate 3 candidate questions to determine their accuracy in identifying patients with limited or marginal health literacy skills. METHODS We studied 305 English-speaking adults attending a university-based primary care clinic. Demographic items, health literacy screening questions, and the Rapid Estimate of Adult Literacy in Medicine (REALM) were administered to patients. To determine the accuracy of the candidate questions for identifying limited or marginal health literacy skills, we plotted area under the receiver operating characteristic (AUROC) curves for each item, using REALM scores as a reference standard. RESULTS The mean age of subjects was 49.5; 67.5% were female, 85.2% Caucasian, and 81.3% insured by TennCare and/or Medicare. Fifty-four (17.7%) had limited and 52 (17.0%) had marginal health literacy skills. One screening question, “How confident are you filling out medical forms by yourself?” was accurate in detecting limited (AUROC of 0.82; 95% confidence interval [CI]=0.77 to 0.86) and limited/marginal (AUROC of 0.79; 95% CI=0.74 to 0.83) health literacy skills. This question had significantly greater AUROC than either of the other questions (P<.01) and also a greater AUROC than questions based on demographic characteristics. CONCLUSIONS One screening question may be sufficient for detecting limited and marginal health literacy skills in clinic populations. PMID:16881950
Orion Flight Performance Design Trades
NASA Technical Reports Server (NTRS)
Jackson, Mark C.; Straube, Timothy
2010-01-01
A significant portion of the Orion pre-PDR design effort has focused on balancing mass with performance. High level performance metrics include abort success rates, lunar surface coverage, landing accuracy and touchdown loads. These metrics may be converted to parameters that affect mass, such as ballast for stabilizing the abort vehicle, propellant to achieve increased lunar coverage or extended missions, or ballast to increase the lift-to-drag ratio to improve entry and landing performance. The Orion Flight Dynamics team was tasked to perform analyses to evaluate many of these trades. These analyses not only provide insight into the physics of each particular trade but, in aggregate, they illustrate the processes used by Orion to balance performance and mass margins, and thereby make design decisions. Lessons learned can be gleaned from a review of these studies which will be useful to other spacecraft system designers. These lessons fall into several categories, including: appropriate application of Monte Carlo analysis in design trades, managing margin in a highly mass-constrained environment, and the use of requirements to balance margin between subsystems and components. This paper provides a review of some of the trades and analyses conducted by the Flight Dynamics team, as well as systems engineering lessons learned.
Tumor margin detection using optical biopsy techniques
NASA Astrophysics Data System (ADS)
Zhou, Yan; Liu, Cheng-hui; Li, Jiyou; Li, Zhongwu; Zhou, Lixin; Chen, Ke; Pu, Yang; He, Yong; Zhu, Ke; Li, Qingbo; Alfano, Robert R.
2014-03-01
The aim of this study is to use the Resonance Raman (RR) and fluorescence spectroscopic technique for tumor margin detection with high accuracy based on native molecular fingerprints of breast and gastrointestinal (GI) tissues. This tumor margins detection method utilizes advantages of RR spectroscopic technique in situ and in real-time to diagnose tumor changes providing powerful tools for clinical guiding intraoperative margin assessments and postoperative treatments. The tumor margin detection procedures by RR spectroscopy were taken by scanning lesion from center or around tumor region in ex-vivo to find the changes in cancerous tissues with the rim of normal tissues using the native molecular fingerprints. The specimens used to analyze tumor margins include breast and GI carcinoma and normal tissues. The sharp margin of the tumor was found by the changes of RR spectral peaks within 2 mm distance. The result was verified using fluorescence spectra with 300 nm, 320 nm and 340 nm excitation, in a typical specimen of gastric cancerous tissue within a positive margin in comparison with normal gastric tissues. This study demonstrates the potential of RR and fluorescence spectroscopy as new approaches with labeling free to determine the intraoperative margin assessment.
Application of high-precision two-way ranging to Galileo Earth-1 encounter navigation
NASA Technical Reports Server (NTRS)
Pollmeier, V. M.; Thurman, S. W.
1992-01-01
The application of precision two-way ranging to orbit determination with relatively short data arcs is investigated for the Galileo spacecraft's approach to its first Earth encounter (December 8, 1990). Analysis of previous S-band (2.3-GHz) ranging data acquired from Galileo indicated that under good signal conditions submeter precision and 10-m ranging accuracy were achieved. It is shown that ranging data of sufficient accuracy, when acquired from multiple stations, can sense the geocentric angular position of a distant spacecraft. A range data filtering technique, in which explicit modeling of range measurement bias parameters for each station pass is utilized, is shown to largely remove the systematic ground system calibration errors and transmission media effects from the Galileo range measurements, which would otherwise corrupt the angle-finding capabilities of the data. The accuracy of the Galileo orbit solutions obtained with S-band Doppler and precision ranging were found to be consistent with simple theoretical calculations, which predicted that angular accuracies of 0.26-0.34 microrad were achievable. In addition, the navigation accuracy achieved with precision ranging was marginally better than that obtained using delta-differenced one-way range (delta DOR), the principal data type that was previously used to obtain spacecraft angular position measurements operationally.
Marlière, Daniel Amaral Alves; Demétrio, Maurício Silva; Picinini, Leonardo Santos; De Oliveira, Rodrigo Guerra; Chaves Netto, Henrique Duque De Miranda
2018-01-01
Assess clinical studies regarding accuracy between virtual planning of computer-guided surgery and actual outcomes of dental implant placements in total edentulous alveolar ridges. A PubMed search was performed to identify only clinical studies published between 2011 and 2016, searching the following combinations of keywords: “Accuracy AND Computer-Assisted Surgery AND Dental Implants.” Study designs were identified using the terms: Case Reports, Clinical study, Randomized Controlled Trial, Systematic Reviews, Meta-Analysis, humans. Level of agreement between the authors in the study selection process was substantial (k = 0.767), and the study eligibility was considered excellent (k = 0.863). Seven articles were included in this review. They describe the use of bone and muco-supported guides, demonstrating angular deviations cervically and apically ranging from (minimum and maximum means), respectively, 1.85–8.4 (°), 0.17–2.17 (mm), and 0.77–2.86 (mm). Angular deviations obtained most inaccuracy in maxila. For cervical and apical deviations, accuracy was preponderantly lower in maxilla. Despite the similar deviations measurement approaches described, clinical relevance of this study may be useful to warn the surgeon that safety margins in clinical situations. PMID:29657542
ERIC Educational Resources Information Center
Wu, Yi-Fang
2015-01-01
Item response theory (IRT) uses a family of statistical models for estimating stable characteristics of items and examinees and defining how these characteristics interact in describing item and test performance. With a focus on the three-parameter logistic IRT (Birnbaum, 1968; Lord, 1980) model, the current study examines the accuracy and…
NASA Astrophysics Data System (ADS)
Cowie, Leanne; Kusznir, Nick
2014-05-01
Subsidence analysis of sedimentary basins and rifted continental margins requires a correction for the anomalous uplift or subsidence arising from mantle dynamic topography. Whilst different global model predictions of mantle dynamic topography may give a broadly similar pattern at long wavelengths, they differ substantially in the predicted amplitude and at shorter wavelengths. As a consequence the accuracy of predicted mantle dynamic topography is not sufficiently good to provide corrections for subsidence analysis. Measurements of present day anomalous subsidence, which we attribute to mantle dynamic topography, have been made for three rifted continental margins; offshore Iberia, the Gulf of Aden and southern Angola. We determine residual depth anomaly (RDA), corrected for sediment loading and crustal thickness variation for 2D profiles running from unequivocal oceanic crust across the continental ocean boundary onto thinned continental crust. Residual depth anomalies (RDA), corrected for sediment loading using flexural backstripping and decompaction, have been calculated by comparing observed and age predicted oceanic bathymetries at these margins. Age predicted bathymetric anomalies have been calculated using the thermal plate model predictions from Crosby & McKenzie (2009). Non-zero sediment corrected RDAs may result from anomalous oceanic crustal thickness with respect to the global average or from anomalous uplift or subsidence. Gravity anomaly inversion incorporating a lithosphere thermal gravity anomaly correction and sediment thickness from 2D seismic reflection data has been used to determine Moho depth, calibrated using seismic refraction, and oceanic crustal basement thickness. Crustal basement thicknesses derived from gravity inversion together with Airy isostasy have been used to correct for variations of crustal thickness from a standard oceanic thickness of 7km. The 2D profiles of RDA corrected for both sediment loading and non-standard crustal thickness provide a measurement of anomalous uplift or subsidence which we attribute to mantle dynamic topography. We compare our sediment and crustal thickness corrected RDA analysis results with published predictions of mantle dynamic topography from global models.
Grande, Antonio Jose; Reid, Hamish; Thomas, Emma; Foster, Charlie; Darton, Thomas C
2016-08-01
Dengue fever is a ubiquitous arboviral infection in tropical and sub-tropical regions, whose incidence has increased over recent decades. In the absence of a rapid point of care test, the clinical diagnosis of dengue is complex. The World Health Organisation has outlined diagnostic criteria for making the diagnosis of dengue infection, which includes the use of the tourniquet test (TT). To assess the quality of the evidence supporting the use of the TT and perform a diagnostic accuracy meta-analysis comparing the TT to antibody response measured by ELISA. A comprehensive literature search was conducted in the following databases to April, 2016: MEDLINE (PubMed), EMBASE, Cochrane Central Register of Controlled Trials, BIOSIS, Web of Science, SCOPUS. Studies comparing the diagnostic accuracy of the tourniquet test with ELISA for the diagnosis of dengue were included. Two independent authors extracted data using a standardized form. A total of 16 studies with 28,739 participants were included in the meta-analysis. Pooled sensitivity for dengue diagnosis by TT was 58% (95% Confidence Interval (CI), 43%-71%) and the specificity was 71% (95% CI, 60%-80%). In the subgroup analysis sensitivity for non-severe dengue diagnosis was 55% (95% CI, 52%-59%) and the specificity was 63% (95% CI, 60%-66%), whilst sensitivity for dengue hemorrhagic fever diagnosis was 62% (95% CI, 53%-71%) and the specificity was 60% (95% CI, 48%-70%). Receiver-operator characteristics demonstrated a test accuracy (AUC) of 0.70 (95% CI, 0.66-0.74). The tourniquet test is widely used in resource poor settings despite currently available evidence demonstrating only a marginal benefit in making a diagnosis of dengue infection alone. The protocol for this systematic review was registered at CRD42015020323.
NASA Astrophysics Data System (ADS)
Zhou, Dapeng; Guo, Lei
2018-01-01
This study aims to address the rapid transfer alignment (RTA) issue of an inertial navigation system with large misalignment angles. The strong nonlinearity and high dimensionality of the system model pose a significant challenge to the estimation of the misalignment angles. In this paper, a 15-dimensional nonlinear model for RTA has been exploited, and it is shown that the functions for the model description exhibit a conditionally linear substructure. Then, a modified stochastic integration filter (SIF) called marginal SIF (MSIF) is developed to incorporate into the nonlinear model, where the number of sample points is significantly reduced but the estimation accuracy of SIF is retained. Comparisons between the MSIF-based RTA and the previously well-known methodologies are carried out through numerical simulations and a van test. The results demonstrate that the newly proposed method has an obvious accuracy advantage over the extended Kalman filter, the unscented Kalman filter and the marginal unscented Kalman filter. Further, the MSIF achieves a comparable performance to SIF, but with a significantly lower computation load.
Alqahtani, Fawaz
2017-01-01
Objective The purpose of this study was to determine the effect of two extraoral computer-aided design (CAD) and computer-aided manufacturing (CAM) systems, in comparison with conventional techniques, on the marginal fit of monolithic CAD/CAM lithium disilicate ceramic crowns. Study design This is an in vitro interventional study. Place and duration of study The study was carried out at the Department of Prosthodontics, School of Dentistry, Prince Sattam Bin Abdul-Aziz University, Saudi Arabia, from December 2015 to April 2016. Methodology A marginal gap of 60 lithium disilicate crowns was evaluated by scanning electron microscopy. In total, 20 pressable lithium disilicate (IPS e.max Press [Ivoclar Vivadent]) ceramic crowns were fabricated using the conventional lost-wax technique as a control group. The experimental all-ceramic crowns were produced based on a scan stone model and milled using two extraoral CAD/CAM systems: the Cerec group was fabricated using the Cerec CAD/CAM system, and the Trios group was fabricated using Trios CAD and milled using Wieland Zenotec CAM. One-way analysis of variance (ANOVA) and the Scheffe post hoc test were used for statistical comparison of the groups (α=0.05). Results The mean (±standard deviation) of the marginal gap of each group was as follows: the Control group was 91.15 (±15.35) µm, the Cerec group was 111.07 (±6.33) µm, and the Trios group was 60.17 (±11.09) µm. One-way ANOVA and the Scheffe post hoc test showed a statistically significant difference in the marginal gap between all groups. Conclusion It can be concluded from the current study that all-ceramic crowns, fabricated using the CAD/CAM system, show a marginal accuracy that is acceptable in clinical environments. The Trios CAD group displayed the smallest marginal gap. PMID:28352204
Nyirenda, Ndeke; Farkas, Daniel L.
2010-01-01
Prevention and early detection of breast cancer are the major prophylactic measures taken to reduce the breast cancer related mortality and morbidity. Clinical management of breast cancer largely relies on the efficacy of the breast-conserving surgeries and the subsequent radiation therapy. A key problem that limits the success of these surgeries is the lack of accurate, real-time knowledge about the positive tumor margins in the surgically excised tumors in the operating room. This leads to tumor recurrence and, hence, the need for repeated surgeries. Current intraoperative techniques such as frozen section pathology or touch imprint cytology severely suffer from poor sampling and non-optimal detection sensitivity. Even though histopathology analysis can provide information on positive tumor margins post-operatively (~2–3 days), this information is of no immediate utility in the operating rooms. In this article, we propose a novel image analysis method for tumor margin assessment based on nuclear morphometry and tissue topology and demonstrate its high sensitivity/specificity in preclinical animal model of breast carcinoma. The method relies on imaging nuclear-specific fluorescence in the excised surgical specimen and on extracting nuclear morphometric parameters (size, number, and area fraction) from the spatial distribution of the observed fluorescence in the tissue. We also report the utility of tissue topology in tumor margin assessment by measuring the fractal dimension in the same set of images. By a systematic analysis of multiple breast tissues specimens, we show here that the proposed method is not only accurate (~97% sensitivity and 96% specificity) in thin sections, but also in three-dimensional (3D) thick tissues that mimic the realistic lumpectomy specimens. Our data clearly precludes the utility of nuclear size as a reliable diagnostic criterion for tumor margin assessment. On the other hand, nuclear area fraction addresses this issue very effectively since it is a combination of both nuclear size and count in any given region of the analyzed image, and thus yields high sensitivity and specificity (~97%) in tumor detection. This is further substantiated by an independent parameter, fractal dimension, based on the tissue topology. Although the basic definition of cancer as an uncontrolled cell growth entails a high nuclear density in tumor regions, a simple but systematic exploration of nuclear distribution in thick tissues by nuclear morphometry and tissue topology as performed in this study has never been carried out, to the best of our knowledge. We discuss the practical aspects of implementing this imaging approach in automated tissue sampling scenario where the accuracy of tumor margin assessment can be significantly increased by scanning the entire surgical specimen rather than sampling only a few sections as in current histopathology analysis. PMID:20446030
Yu, Xiao; Ding, Enjie; Chen, Chunxu; Liu, Xiaoming; Li, Li
2015-01-01
Because roller element bearings (REBs) failures cause unexpected machinery breakdowns, their fault diagnosis has attracted considerable research attention. Established fault feature extraction methods focus on statistical characteristics of the vibration signal, which is an approach that loses sight of the continuous waveform features. Considering this weakness, this article proposes a novel feature extraction method for frequency bands, named Window Marginal Spectrum Clustering (WMSC) to select salient features from the marginal spectrum of vibration signals by Hilbert–Huang Transform (HHT). In WMSC, a sliding window is used to divide an entire HHT marginal spectrum (HMS) into window spectrums, following which Rand Index (RI) criterion of clustering method is used to evaluate each window. The windows returning higher RI values are selected to construct characteristic frequency bands (CFBs). Next, a hybrid REBs fault diagnosis is constructed, termed by its elements, HHT-WMSC-SVM (support vector machines). The effectiveness of HHT-WMSC-SVM is validated by running series of experiments on REBs defect datasets from the Bearing Data Center of Case Western Reserve University (CWRU). The said test results evidence three major advantages of the novel method. First, the fault classification accuracy of the HHT-WMSC-SVM model is higher than that of HHT-SVM and ST-SVM, which is a method that combines statistical characteristics with SVM. Second, with Gauss white noise added to the original REBs defect dataset, the HHT-WMSC-SVM model maintains high classification accuracy, while the classification accuracy of ST-SVM and HHT-SVM models are significantly reduced. Third, fault classification accuracy by HHT-WMSC-SVM can exceed 95% under a Pmin range of 500–800 and a m range of 50–300 for REBs defect dataset, adding Gauss white noise at Signal Noise Ratio (SNR) = 5. Experimental results indicate that the proposed WMSC method yields a high REBs fault classification accuracy and a good performance in Gauss white noise reduction. PMID:26540059
Yu, Xiao; Ding, Enjie; Chen, Chunxu; Liu, Xiaoming; Li, Li
2015-11-03
Because roller element bearings (REBs) failures cause unexpected machinery breakdowns, their fault diagnosis has attracted considerable research attention. Established fault feature extraction methods focus on statistical characteristics of the vibration signal, which is an approach that loses sight of the continuous waveform features. Considering this weakness, this article proposes a novel feature extraction method for frequency bands, named Window Marginal Spectrum Clustering (WMSC) to select salient features from the marginal spectrum of vibration signals by Hilbert-Huang Transform (HHT). In WMSC, a sliding window is used to divide an entire HHT marginal spectrum (HMS) into window spectrums, following which Rand Index (RI) criterion of clustering method is used to evaluate each window. The windows returning higher RI values are selected to construct characteristic frequency bands (CFBs). Next, a hybrid REBs fault diagnosis is constructed, termed by its elements, HHT-WMSC-SVM (support vector machines). The effectiveness of HHT-WMSC-SVM is validated by running series of experiments on REBs defect datasets from the Bearing Data Center of Case Western Reserve University (CWRU). The said test results evidence three major advantages of the novel method. First, the fault classification accuracy of the HHT-WMSC-SVM model is higher than that of HHT-SVM and ST-SVM, which is a method that combines statistical characteristics with SVM. Second, with Gauss white noise added to the original REBs defect dataset, the HHT-WMSC-SVM model maintains high classification accuracy, while the classification accuracy of ST-SVM and HHT-SVM models are significantly reduced. Third, fault classification accuracy by HHT-WMSC-SVM can exceed 95% under a Pmin range of 500-800 and a m range of 50-300 for REBs defect dataset, adding Gauss white noise at Signal Noise Ratio (SNR) = 5. Experimental results indicate that the proposed WMSC method yields a high REBs fault classification accuracy and a good performance in Gauss white noise reduction.
Mock, U; Dieckmann, K; Wolff, U; Knocke, T H; Pötter, R
1999-08-01
Geometrical accuracy in patient positioning can vary substantially during external radiotherapy. This study estimated the set-up accuracy during pelvic irradiation for gynecological malignancies for determination of safety margins (planning target volume, PTV). Based on electronic portal imaging devices (EPID), 25 patients undergoing 4-field pelvic irradiation for gynecological malignancies were analyzed with regard to set-up accuracy during the treatment course. Regularly performed EPID images were used in order to systematically assess the systematic and random component of set-up displacements. Anatomical matching of verification and simulation images was followed by measuring corresponding distances between the central axis and anatomical features. Data analysis of set-up errors referred to the x-, y-,and z-axes. Additionally, cumulative frequencies were evaluated. A total of 50 simulation films and 313 verification images were analyzed. For the anterior-posterior (AP) beam direction mean deviations along the x- and z-axes were 1.5 mm and -1.9 mm, respectively. Moreover, random errors of 4.8 mm (x-axis) and 3.0 mm (z-axis) were determined. Concerning the latero-lateral treatment fields, the systematic errors along the two axes were calculated to 2.9 mm (y-axis) and -2.0 mm (z-axis) and random errors of 3.8 mm and 3.5 mm were found, respectively. The cumulative frequency of misalignments < or =5 mm showed values of 75% (AP fields) and 72% (latero-lateral fields). With regard to cumulative frequencies < or =10 mm quantification revealed values of 97% for both beam directions. During external pelvic irradiation therapy for gynecological malignancies, EPID images on a regular basis revealed acceptable set-up inaccuracies. Safety margins (PTV) of 1 cm appear to be sufficient, accounting for more than 95% of all deviations.
Accuracy of computer-guided implantation in a human cadaver model.
Yatzkair, Gustavo; Cheng, Alice; Brodie, Stan; Raviv, Eli; Boyan, Barbara D; Schwartz, Zvi
2015-10-01
To examine the accuracy of computer-guided implantation using a human cadaver model with reduced experimental variability. Twenty-eight (28) dental implants representing 12 clinical cases were placed in four cadaver heads using a static guided implantation template. All planning and surgeries were performed by one clinician. All radiographs and measurements were performed by two examiners. The distance of the implants from buccal and lingual bone and mesial implant or tooth was analyzed at the apical and coronal levels, and measurements were compared to the planned values. No significant differences were seen between planned and implanted measurements. Average deviation of an implant from its planning radiograph was 0.8 mm, which is within the range of variability expected from CT analysis. Guided implantation can be used safely with a margin of error of 1 mm. © 2014 The Authors. Clinical Oral Implants Research Published by John Wiley & Sons Ltd.
Detection of marginal leakage of Class V restorations in vitro by micro-computed tomography.
Zhao, X Y; Li, S B; Gu, L J; Li, Y
2014-01-01
This in vitro study evaluated the efficacy of micro-computed tomography (CT) in marginal leakage detection of Class V restorations. Standardized Class V preparations with cervical margins in dentin and occlusal margins in enamel were made in 20 extracted human molars and restored with dental bonding agents and resin composite. All teeth were then immersed in 50% ammoniacal silver nitrate solution for 12 hours, followed by a developing solution for eight hours. Each restoration was scanned by micro-CT, the depth of marginal silver leakage in the central scanning section was measured, and the three-dimensional images of the silver leakage around each restoration were reconstructed. Afterward, all restorations were cut through the center and examined for leakage depth using a microscope. The silver leakage depth of each restoration obtained by the micro-CT and the microscope were compared for equivalency. The silver leakage depth in cervical walls observed by micro-CT and microscope showed no significant difference; however, in certain cases the judgment of leakage depth in the occlusal wall in micro-CT image was affected by adjacent enamel structure, providing less leakage depth than was observed with the microscope (p<0.01). Micro-CT displayed the three-dimensional image of the leakage around the Class V restorations with clear borders only in the dentin region. It can be concluded that micro-CT can detect nondestructively the leakage around a resin composite restoration in two and three dimensions, with accuracy comparable to that of the conventional microscope method in the dentin region but with inferior accuracy in the enamel region.
NASA Astrophysics Data System (ADS)
Prince, John R.
1982-12-01
Sensitivity, specificity, and predictive accuracy have been shown to be useful measures of the clinical efficacy of diagnostic tests and can be used to predict the potential improvement in diagnostic certitude resulting from the introduction of a competing technology. This communication demonstrates how the informal use of clinical decision analysis may guide health planners in the allocation of resources, purchasing decisions, and implementation of high technology. For didactic purposes the focus is on a comparison between conventional planar radioscintigraphy (RS) and single photon transverse section emission conputed tomography (SPECT). For example, positive predictive accuracy (PPA) for brain RS in a specialist hospital with a 50% disease prevalance is about 95%. SPECT should increase this predicted accuracy to 96%. In a primary care hospital with only a 15% disease prevalance the PPA is only 77% and SPECT may increase this accuracy to about 79%. Similar calculations based on published data show that marginal improvements are expected with SPECT in the liver. It is concluded that: a) The decision to purchase a high technology imaging modality such as SPECT for clinical purposes should be analyzed on an individual organ system and institutional basis. High technology may be justified in specialist hospitals but not necessarily in primary care hospitals. This is more dependent on disease prevalance than procedure volume; b) It is questionable whether SPECT imaging will be competitive with standard RS procedures. Research should concentrate on the development of different medical applications.
Tadayyon, Hadi; Sannachi, Lakshmanan; Gangeh, Mehrdad J.; Kim, Christina; Ghandi, Sonal; Trudeau, Maureen; Pritchard, Kathleen; Tran, William T.; Slodkowska, Elzbieta; Sadeghi-Naini, Ali; Czarnota, Gregory J.
2017-01-01
Quantitative ultrasound (QUS) can probe tissue structure and analyze tumour characteristics. Using a 6-MHz ultrasound system, radiofrequency data were acquired from 56 locally advanced breast cancer patients prior to their neoadjuvant chemotherapy (NAC) and QUS texture features were computed from regions of interest in tumour cores and their margins as potential predictive and prognostic indicators. Breast tumour molecular features were also collected and used for analysis. A multiparametric QUS model was constructed, which demonstrated a response prediction accuracy of 88% and ability to predict patient 5-year survival rates (p = 0.01). QUS features demonstrated superior performance in comparison to molecular markers and the combination of QUS and molecular markers did not improve response prediction. This study demonstrates, for the first time, that non-invasive QUS features in the core and margin of breast tumours can indicate breast cancer response to neoadjuvant chemotherapy (NAC) and predict five-year recurrence-free survival. PMID:28401902
Tadayyon, Hadi; Sannachi, Lakshmanan; Gangeh, Mehrdad J; Kim, Christina; Ghandi, Sonal; Trudeau, Maureen; Pritchard, Kathleen; Tran, William T; Slodkowska, Elzbieta; Sadeghi-Naini, Ali; Czarnota, Gregory J
2017-04-12
Quantitative ultrasound (QUS) can probe tissue structure and analyze tumour characteristics. Using a 6-MHz ultrasound system, radiofrequency data were acquired from 56 locally advanced breast cancer patients prior to their neoadjuvant chemotherapy (NAC) and QUS texture features were computed from regions of interest in tumour cores and their margins as potential predictive and prognostic indicators. Breast tumour molecular features were also collected and used for analysis. A multiparametric QUS model was constructed, which demonstrated a response prediction accuracy of 88% and ability to predict patient 5-year survival rates (p = 0.01). QUS features demonstrated superior performance in comparison to molecular markers and the combination of QUS and molecular markers did not improve response prediction. This study demonstrates, for the first time, that non-invasive QUS features in the core and margin of breast tumours can indicate breast cancer response to neoadjuvant chemotherapy (NAC) and predict five-year recurrence-free survival.
Shimizu, Sakura; Shinya, Akikazu; Kuroda, Soichi; Gomi, Harunori
2017-07-26
The accuracy of prostheses affects clinical success and is, in turn, affected by the accuracy of the scanner and CAD programs. Thus, their accuracy is important. The first aim of this study was to evaluate the accuracy of an intraoral scanner with active triangulation (Cerec Omnicam), an intraoral scanner with a confocal laser (3Shape Trios), and an extraoral scanner with active triangulation (D810). The second aim of this study was to compare the accuracy of the digital crowns designed with two different scanner/CAD combinations. The accuracy of the intraoral scanners and extraoral scanner was clinically acceptable. Marginal and internal fit of the digital crowns fabricated using the intraoral scanner and CAD programs were inferior to those fabricated using the extraoral scanner and CAD programs.
Thematic mapping, land use, geological structure and water resources in central Spain
NASA Technical Reports Server (NTRS)
Delascuevas, N. (Principal Investigator)
1976-01-01
The author has identified the following significant results. The images can be positioned in an absolute reference system (geographical coordinates or polar stereographic coordinates) by means of their marginal indicators. By digital analysis of LANDSAT data and geometric positioning of pixels in UTM projection, accuracy was achieved for corrected MSS information which could be used for updating maps at scale 1:200,000 or smaller. Results show that adjustment of the UTM grid was better obtained by a first order, or even second order, algorithm of geometric correction. Digital analysis of LANDSAT data from the Madrid area showed that this line of study was promising for automatic classification of data applied to thematic cartography and soils identification.
NASA Astrophysics Data System (ADS)
Gabor, A.; Jivanescu, A.; Zaharia, C.; Hategan, S.; Topala, F. I.; Levai, C. M.; Negrutiu, M. L.; Sinescu, C.; Duma, V.-F.; Bradu, A.; Podoleanu, A. Gh.
2016-03-01
Digital impressions were introduced to overcome some of the obstacles due to traditional impression materials and techniques. The aim of this in vitro study is to compare the accuracy of all ceramic crowns obtained with digital impression and CAD-CAM technology with the accuracy of those obtained with conventional impression techniques. Two groups of 10 crowns each have been considered. The digital data obtained from Group 1 have been processed and the all-ceramic crowns were milled with a CAD/CAM technology (CEREC MCX, Sirona). The all ceramic crowns in Group 2 were obtained with the classical technique of pressing (emax, Ivoclar, Vivadent). The evaluation of the marginal adaptation was performed with Time Domain Optical Coherence Tomography (TD OCT), working at a wavelength of 1300 nm. Tri-dimensional (3D) reconstructions of the selected areas were obtained. Based on the findings in this study, one may conclude that the marginal accuracy of all ceramic crowns fabricated with digital impression and the CAD/CAM technique is superior to the conventional impression technique.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Hoang, P; Wierzbicki, M; Juravinski Cancer Centre, Medical Physics Department, Hamilton, Ontario
A four dimensional computed tomography (4DCT) image is acquired for all radically treated, lung cancer patients to define the internal target volume (ITV), which encompasses tumour motion due to breathing and subclinical disease. Patient set-up error and anatomical motion that is not due to breathing is addressed through an additional 1 cm margin around the ITV to obtain the planning target volume (PTV). The objective of this retrospective study is to find the minimum PTV margin that provides an acceptable probability of delivering the prescribed dose to the ITV. Acquisition of a kV cone beam computed tomography (CBCT) image atmore » each fraction was used to shift the treatment couch to accurately align the spinal cord and carina. Our method utilized deformable image registration to automatically position the planning ITV on each CBCT. We evaluated the percentage of the ITV surface that fell within various PTVs for 79 fractions across 18 patients. Treatment success was defined as a situation where at least 99% of the ITV is covered by the PTV. Overall, this is to be achieved in at least 90% of the treatment fractions. The current approach with a 1cm PTV margin was successful ∼96% of the time. This analysis revealed that the current margin can be reduced to 0.8cm isotropic or 0.6×0.6×1 cm{sup 3} non-isotropic, which were successful 92 and 91 percent of the time respectively. Moreover, we have shown that these margins maintain accuracy, despite intrafractional variation, and maximize CBCT image guidance capabilities.« less
Dynamic CT myocardial perfusion imaging: performance of 3D semi-automated evaluation software.
Ebersberger, Ullrich; Marcus, Roy P; Schoepf, U Joseph; Lo, Gladys G; Wang, Yining; Blanke, Philipp; Geyer, Lucas L; Gray, J Cranston; McQuiston, Andrew D; Cho, Young Jun; Scheuering, Michael; Canstein, Christian; Nikolaou, Konstantin; Hoffmann, Ellen; Bamberg, Fabian
2014-01-01
To evaluate the performance of three-dimensional semi-automated evaluation software for the assessment of myocardial blood flow (MBF) and blood volume (MBV) at dynamic myocardial perfusion computed tomography (CT). Volume-based software relying on marginal space learning and probabilistic boosting tree-based contour fitting was applied to CT myocardial perfusion imaging data of 37 subjects. In addition, all image data were analysed manually and both approaches were compared with SPECT findings. Study endpoints included time of analysis and conventional measures of diagnostic accuracy. Of 592 analysable segments, 42 showed perfusion defects on SPECT. Average analysis times for the manual and software-based approaches were 49.1 ± 11.2 and 16.5 ± 3.7 min respectively (P < 0.01). There was strong agreement between the two measures of interest (MBF, ICC = 0.91, and MBV, ICC = 0.88, both P < 0.01) and no significant difference in MBF/MBV with respect to diagnostic accuracy between the two approaches for both MBF and MBV for manual versus software-based approach; respectively; all comparisons P > 0.05. Three-dimensional semi-automated evaluation of dynamic myocardial perfusion CT data provides similar measures and diagnostic accuracy to manual evaluation, albeit with substantially reduced analysis times. This capability may aid the integration of this test into clinical workflows. • Myocardial perfusion CT is attractive for comprehensive coronary heart disease assessment. • Traditional image analysis methods are cumbersome and time-consuming. • Automated 3D perfusion software shortens analysis times. • Automated 3D perfusion software increases standardisation of myocardial perfusion CT. • Automated, standardised analysis fosters myocardial perfusion CT integration into clinical practice.
Automated detection of breast cancer in resected specimens with fluorescence lifetime imaging
NASA Astrophysics Data System (ADS)
Phipps, Jennifer E.; Gorpas, Dimitris; Unger, Jakob; Darrow, Morgan; Bold, Richard J.; Marcu, Laura
2018-01-01
Re-excision rates for breast cancer lumpectomy procedures are currently nearly 25% due to surgeons relying on inaccurate or incomplete methods of evaluating specimen margins. The objective of this study was to determine if cancer could be automatically detected in breast specimens from mastectomy and lumpectomy procedures by a classification algorithm that incorporated parameters derived from fluorescence lifetime imaging (FLIm). This study generated a database of co-registered histologic sections and FLIm data from breast cancer specimens (N = 20) and a support vector machine (SVM) classification algorithm able to automatically detect cancerous, fibrous, and adipose breast tissue. Classification accuracies were greater than 97% for automated detection of cancerous, fibrous, and adipose tissue from breast cancer specimens. The classification worked equally well for specimens scanned by hand or with a mechanical stage, demonstrating that the system could be used during surgery or on excised specimens. The ability of this technique to simply discriminate between cancerous and normal breast tissue, in particular to distinguish fibrous breast tissue from tumor, which is notoriously challenging for optical techniques, leads to the conclusion that FLIm has great potential to assess breast cancer margins. Identification of positive margins before waiting for complete histologic analysis could significantly reduce breast cancer re-excision rates.
Investigation and evaluation of shuttle/GPS navigation system
NASA Technical Reports Server (NTRS)
Nilsen, P. W.
1977-01-01
Iterative procedures were used to analyze the performance of two preliminary shuttle/GPS navigation system configurations: an early OFT experimental system and a more sophisticated system which consolidates several separate navigation functions thus permitting net cost savings from decreased shuttle avionics weight and power consumption, and from reduced ground data processing. The GPS system can provide on-orbit navigation accuracy an order of magnitude better than the baseline system, with very adequate link margins. The worst-case link margin is 4.3 dB. This link margin accounts for shuttle RF circuit losses which were minimized under the constraints of program schedule and environmental limitations. Implicit in the link analyses are the location trade-offs for preamplifiers and antennas.
Three-dimensional marginal separation
NASA Technical Reports Server (NTRS)
Duck, Peter W.
1988-01-01
The three dimensional marginal separation of a boundary layer along a line of symmetry is considered. The key equation governing the displacement function is derived, and found to be a nonlinear integral equation in two space variables. This is solved iteratively using a pseudo-spectral approach, based partly in double Fourier space, and partly in physical space. Qualitatively, the results are similar to previously reported two dimensional results (which are also computed to test the accuracy of the numerical scheme); however quantitatively the three dimensional results are much different.
Automating digital leaf measurement: the tooth, the whole tooth, and nothing but the tooth.
Corney, David P A; Tang, H Lilian; Clark, Jonathan Y; Hu, Yin; Jin, Jing
2012-01-01
Many species of plants produce leaves with distinct teeth around their margins. The presence and nature of these teeth can often help botanists to identify species. Moreover, it has long been known that more species native to colder regions have teeth than species native to warmer regions. It has therefore been suggested that fossilized remains of leaves can be used as a proxy for ancient climate reconstruction. Similar studies on living plants can help our understanding of the relationships. The required analysis of leaves typically involves considerable manual effort, which in practice limits the number of leaves that are analyzed, potentially reducing the power of the results. In this work, we describe a novel algorithm to automate the marginal tooth analysis of leaves found in digital images. We demonstrate our methods on a large set of images of whole herbarium specimens collected from Tilia trees (also known as lime, linden or basswood). We chose the genus Tilia as its constituent species have toothed leaves of varied size and shape. In a previous study we extracted c.1600 leaves automatically from a set of c.1100 images. Our new algorithm locates teeth on the margins of such leaves and extracts features such as each tooth's area, perimeter and internal angles, as well as counting them. We evaluate an implementation of our algorithm's performance against a manually analyzed subset of the images. We found that the algorithm achieves an accuracy of 85% for counting teeth and 75% for estimating tooth area. We also demonstrate that the automatically extracted features are sufficient to identify different species of Tilia using a simple linear discriminant analysis, and that the features relating to teeth are the most useful.
D’Avolio, Leonard W.; Litwin, Mark S.; Rogers, Selwyn O.; Bui, Alex A. T.
2007-01-01
Prostate cancer removal surgeries that result in tumor found at the surgical margin, otherwise known as a positive surgical margin, have a significantly higher chance of biochemical recurrence and clinical progression. To support clinical outcomes assessment a system was designed to automatically identify, extract, and classify key phrases from pathology reports describing this outcome. Heuristics and boundary detection were used to extract phrases. Phrases were then classified using support vector machines into one of three classes: ‘positive (involved) margins,’ ‘negative (uninvolved) margins,’ and ‘not-applicable or definitive.’ A total of 851 key phrases were extracted from a sample of 782 reports produced between 1996 and 2006 from two major hospitals. Despite differences in reporting style, at least 1 sentence containing a diagnosis was extracted from 780 of the 782 reports (99.74%). Of the 851 sentences extracted, 97.3% contained diagnoses. Overall accuracy of automated classification of extracted sentences into the three categories was 97.18%. PMID:18693818
Garofolo, Sabrina; Piazza, Cesare; Del Bon, Francesca; Mangili, Stefano; Guastini, Luca; Mora, Francesco; Nicolai, Piero; Peretti, Giorgio
2015-04-01
The high rate of positive margins after transoral laser microsurgery (TLM) remains a matter of debate. This study investigates the effect of intraoperative narrow band imaging (NBI) examination on the incidence of positive superficial surgical margins in early glottic cancer treated by TLM. Between January 2012 and October 2013, 82 patients affected by Tis-T1a glottic cancer were treated with TLM by type I or II cordectomies. Intraoperative NBI evaluation was performed using 0-degree and 70-degree rigid telescopes. Surgical specimens were oriented by marking the superior edge with black ink and sent to a dedicated pathologist. Comparison between the rate of positive superficial margins in the present cohort and in a matched historical control group treated in the same way without intraoperative NBI was calculated by chi-square test. At histopathological examination, all surgical margins were negative in 70 patients, whereas 7 had positive deep margins, 2 close, and 3 positive superficial margins. The rate of positive superficial margins was thus 3.6% in the present group and 23.7% in the control cohort (P<.001). Routine use of intraoperative NBI increases the accuracy of neoplastic superficial spreading evaluation during TLM for early glottic cancer. © The Author(s) 2014.
Hwang, Chang Yun; Song, Tae Jun; Moon, Sung-Hoon; Lee, Don; Park, Do Hyun; Seo, Dong Wan; Lee, Sung Koo; Kim, Myung-Hwan
2009-01-01
Background/Aims Although endoscopic ultrasound guided fine needle aspiration (EUS-FNA) has been introduced and its use has been increasing in Korea, there have not been many reports about its performance. The aim of this study was to assess the utility of EUS-FNA without on-site cytopathologist in establishing the diagnosis of solid pancreatic and peripancreatic masses from a single institution in Korea. Methods Medical records of 139 patients who underwent EUS-FNA for pancreatic and peripancreatic solid mass in the year 2007, were retrospectively reviewed. By comparing cytopathologic diagnosis of FNA with final diagnosis, sensitivity, specificity, and accuracy were determined, and factors influencing the accuracy as well as complications were analyzed. Results One hundred twenty out of 139 cases had final diagnosis of malignancy. Sensitivity, specificity, and accuracy of EUS-FNA were 82%, 89%, and 83%, respectively, and positive and negative predictive values were 100% and 46%, respectively. As for factors influencing the accuracy of FNA, lesion size was marginally significant (p-value 0.08) by multivariate analysis. Conclusions EUS-FNA performed without on-site cytopathologist was found to be accurate and safe, and thus EUS-FNA should be a part of the standard management algorithm for pancreatic and peripancreatic mass. PMID:20431733
Comparison of Laser Scanning Diagnostic Devices for Early Glaucoma Detection.
Schulze, Andreas; Lamparter, Julia; Pfeiffer, Norbert; Berisha, Fatmire; Schmidtmann, Irene; Hoffmann, Esther M
2015-08-01
To compare the diagnostic accuracy and to evaluate the correlation of optic nerve head and retinal nerve fiber layer thickness values between Fourier-Domain optical coherence tomography (FD-OCT), confocal scanning laser ophthalmoscopy (CSLO), and scanning laser polarimetry (SLP) for early glaucoma detection. Ninety-three patients with early open-angle glaucoma, 58 patients with ocular hypertension, and 60 healthy control subjects were included in this observational, cross-sectional study. All study participants underwent FD-OCT (RTVue-100), CSLO (HRT3), and SLP (GDx VCC) imaging of the optic nerve head and the retinal nerve fiber layer. Area under the receiver operating characteristic curves (AUROC) and Bland-Altman analysis were performed. The parameters with the highest diagnostic accuracy were found for FD-OCT cup-to-disc ratio (AUROC=0.841), for SLP NFI (AUROC=0.835), and for CSLO cup-to-disc ratio (AUROC=0.789). Diagnostic accuracy of the best CSLO and SLP parameter was similar (P=0.259). There was a small statistically significant difference between the best CSLO and FD-OCT parameters for differentiating between glaucoma and healthy eyes (P=0.047). FD-OCT and SLP have a similarly good diagnostic ability to distinguish between early glaucoma and healthy subjects. The diagnostic accuracy of CSLO was comparable with SLP and marginally lower compared with FD-OCT.
Barbieri, Christopher E; Cha, Eugene K; Chromecki, Thomas F; Dunning, Allison; Lotan, Yair; Svatek, Robert S; Scherr, Douglas S; Karakiewicz, Pierre I; Sun, Maxine; Mazumdar, Madhu; Shariat, Shahrokh F
2012-03-01
• To employ decision curve analysis to determine the impact of nuclear matrix protein 22 (NMP22) on clinical decision making in the detection of bladder cancer using data from a prospective trial. • The study included 1303 patients at risk for bladder cancer who underwent cystoscopy, urine cytology and measurement of urinary NMP22 levels. • We constructed several prediction models to estimate risk of bladder cancer. The base model was generated using patient characteristics (age, gender, race, smoking and haematuria); cytology and NMP22 were added to the base model to determine effects on predictive accuracy. • Clinical net benefit was calculated by summing the benefits and subtracting the harms and weighting these by the threshold probability at which a patient or clinician would opt for cystoscopy. • In all, 72 patients were found to have bladder cancer (5.5%). In univariate analyses, NMP22 was the strongest predictor of bladder cancer presence (predictive accuracy 71.3%), followed by age (67.5%) and cytology (64.3%). • In multivariable prediction models, NMP22 improved the predictive accuracy of the base model by 8.2% (area under the curve 70.2-78.4%) and of the base model plus cytology by 4.2% (area under the curve 75.9-80.1%). • Decision curve analysis revealed that adding NMP22 to other models increased clinical benefit, particularly at higher threshold probabilities. • NMP22 is a strong, independent predictor of bladder cancer. • Addition of NMP22 improves the accuracy of standard predictors by a statistically and clinically significant margin. • Decision curve analysis suggests that integration of NMP22 into clinical decision making helps avoid unnecessary cystoscopies, with minimal increased risk of missing a cancer. © 2011 THE AUTHORS. BJU INTERNATIONAL © 2011 BJU INTERNATIONAL.
Federal Register 2010, 2011, 2012, 2013, 2014
2010-03-22
... Staff Guidance on Implementation of a Seismic Margin Analysis for New Reactors Based on Probabilistic... Seismic Margin Analysis for New Reactors Based on Probabilistic Risk Assessment,'' (Agencywide Documents.../COL-ISG-020 ``Implementation of a Seismic Margin Analysis for New Reactors Based on Probabilistic Risk...
Li, Jiangeng; Su, Lei; Pang, Zenan
2015-12-01
Feature selection techniques have been widely applied to tumor gene expression data analysis in recent years. A filter feature selection method named marginal Fisher analysis score (MFA score) which is based on graph embedding has been proposed, and it has been widely used mainly because it is superior to Fisher score. Considering the heavy redundancy in gene expression data, we proposed a new filter feature selection technique in this paper. It is named MFA score+ and is based on MFA score and redundancy excluding. We applied it to an artificial dataset and eight tumor gene expression datasets to select important features and then used support vector machine as the classifier to classify the samples. Compared with MFA score, t test and Fisher score, it achieved higher classification accuracy.
The Development of a Handbook for Astrobee F Performance and Stability Analysis
NASA Technical Reports Server (NTRS)
Wolf, R. S.
1982-01-01
An astrobee F performance and stability analysis is presented, for use by the NASA Sounding Rocket Division. The performance analysis provides information regarding altitude, mach number, dynamic pressure, and velocity as functions of time since launch. It is found that payload weight has the greatest effect on performance, and performance prediction accuracy was calculated to remain within 1%. In addition, to assure sufficient flight stability, a predicted rigid-body static margin of at least 8% of the total vehicle length is required. Finally, fin cant angle predictions are given in order to achieve a 2.5 cycle per second burnout roll rate, based on obtaining 75% of the steady roll rate. It is noted that this method can be used by flight performance engineers to create a similar handbook for any sounding rocket series.
Rajagopal, Praveen; Chitre, Vidya; Aras, Meena A
2012-01-01
Traditionally, inlay casting waxes have been used to fabricate patterns for castings. Newer resin pattern materials offer greater rigidity and strength, allowing easier laboratory and intraoral adjustment without the fear of pattern damage. They also claim to possess a greater dimensional stability when compared to inlay wax. This study attempted to determine and compare the marginal accuracy of patterns fabricated from an inlay casting wax, an autopolymerized pattern resin and a light polymerized pattern resin on storage off the die for varying time intervals. Ten patterns each were fabricated from an inlay casting wax (GC Corp., Tokyo, Japan), an autopolymerized resin pattern material (Pattern resin, GC Corp, Tokyo, Japan) and a light-cured resin pattern material (Palavit GLC, Hereaus Kulzer GmbH, Germany). The completed patterns were stored off the die at room temperature. Marginal gaps were evaluated by reseating the patterns on their respective dies and observing it under a stereomicroscope at 1, 12, and 24 h intervals after pattern fabrication. The results revealed that the inlay wax showed a significantly greater marginal discrepancy at the 12 and 24 h intervals. The autopolymerized resin showed an initial (at 1 h) marginal discrepancy slightly greater than inlay wax, but showed a significantly less marginal gap (as compared to inlay wax) at the other two time intervals. The light-cured resin proved to be significantly more dimensionally stable, and showed minimal change during the storage period. The resin pattern materials studied, undergo a significantly less dimensional change than the inlay waxes on prolonged storage. They would possibly be a better alternative to inlay wax in situations requiring high precision or when delayed investment (more than 1 h) of patterns can be expected.
Robust Flutter Margin Analysis that Incorporates Flight Data
NASA Technical Reports Server (NTRS)
Lind, Rick; Brenner, Martin J.
1998-01-01
An approach for computing worst-case flutter margins has been formulated in a robust stability framework. Uncertainty operators are included with a linear model to describe modeling errors and flight variations. The structured singular value, mu, computes a stability margin that directly accounts for these uncertainties. This approach introduces a new method of computing flutter margins and an associated new parameter for describing these margins. The mu margins are robust margins that indicate worst-case stability estimates with respect to the defined uncertainty. Worst-case flutter margins are computed for the F/A-18 Systems Research Aircraft using uncertainty sets generated by flight data analysis. The robust margins demonstrate flight conditions for flutter may lie closer to the flight envelope than previously estimated by p-k analysis.
Tang, Z H; Geng, Z M; Chen, C; Si, S B; Cai, Z Q; Song, T Q; Gong, P; Jiang, L; Qiu, Y H; He, Y; Zhai, W L; Li, S P; Zhang, Y C; Yang, Y
2018-05-01
Objective: To investigate the clinical value of Bayesian network in predicting survival of patients with advanced gallbladder cancer(GBC)who underwent curative intent surgery. Methods: The clinical data of patients with advanced GBC who underwent curative intent surgery in 9 institutions from January 2010 to December 2015 were analyzed retrospectively.A median survival time model based on a tree augmented naïve Bayes algorithm was established by Bayesia Lab software.The survival time, number of metastatic lymph nodes(NMLN), T stage, pathological grade, margin, jaundice, liver invasion, age, sex and tumor morphology were included in this model.Confusion matrix, the receiver operating characteristic curve and area under the curve were used to evaluate the accuracy of the model.A priori statistical analysis of these 10 variables and a posterior analysis(survival time as the target variable, the remaining factors as the attribute variables)was performed.The importance rankings of each variable was calculated with the polymorphic Birnbaum importance calculation based on the posterior analysis results.The survival probability forecast table was constructed based on the top 4 prognosis factors. The survival curve was drawn by the Kaplan-Meier method, and differences in survival curves were compared using the Log-rank test. Results: A total of 316 patients were enrolled, including 109 males and 207 females.The ratio of male to female was 1.0∶1.9, the age was (62.0±10.8)years.There was 298 cases(94.3%) R0 resection and 18 cases(5.7%) R1 resection.T staging: 287 cases(90.8%) T3 and 29 cases(9.2%) T4.The median survival time(MST) was 23.77 months, and the 1, 3, 5-year survival rates were 67.4%, 40.8%, 32.0%, respectively.For the Bayesian model, the number of correctly predicted cases was 121(≤23.77 months) and 115(>23.77 months) respectively, leading to a 74.86% accuracy of this model.The prior probability of survival time was 0.503 2(≤23.77 months) and 0.496 8(>23.77 months), the importance ranking showed that NMLN(0.366 6), margin(0.350 1), T stage(0.319 2) and pathological grade(0.258 9) were the top 4 prognosis factors influencing the postoperative MST.These four factors were taken as observation variables to get the probability of patients in different survival periods.Basing on these results, a survival prediction score system including NMLN, margin, T stage and pathological grade was designed, the median survival time(month) of 4-9 points were 66.8, 42.4, 26.0, 9.0, 7.5 and 2.3, respectively, there was a statistically significant difference in the different points( P <0.01). Conclusions: The survival prediction model of GBC based on Bayesian network has high accuracy.NMLN, margin, T staging and pathological grade are the top 4 risk factors affecting the survival of patients with advanced GBC who underwent curative resection.The survival prediction score system based on these four factors could be used to predict the survival and to guide the decision making of patients with advanced GBC.
Examining the margins: a concept analysis of marginalization.
Vasas, Elyssa B
2005-01-01
The aim of this analysis is to explore the concept of social marginalization for the purpose of concept development. Specifically, the article intends to clarify the relationship between health disparities and marginalization and generate knowledge about working with people who are socially marginalized. Concept development evolved from the critical analysis of relevant literature generated through searches of nursing and social science databases. Literature was organized thematically and themes related to marginalization as a social process were included and analyzed. The article explores the challenges of using marginalization as an independent concept and suggests areas for future inquiry and research.
Adaptive Quadrature for Item Response Models. Research Report. ETS RR-06-29
ERIC Educational Resources Information Center
Haberman, Shelby J.
2006-01-01
Adaptive quadrature is applied to marginal maximum likelihood estimation for item response models with normal ability distributions. Even in one dimension, significant gains in speed and accuracy of computation may be achieved.
Large Area Crop Inventory Experiment (LACIE). Phase 1: Evaluation report
NASA Technical Reports Server (NTRS)
1976-01-01
It appears that the Large Area Crop Inventory Experiment over the Great Plains, can with a reasonable expectation, be a satisfactory component of a 90/90 production estimator. The area estimator produced more accurate area estimates for the total winter wheat region than for the mixed spring and winter wheat region of the northern Great Plains. The accuracy does appear to degrade somewhat in regions of marginal agriculture where there are small fields and abundant confusion crops. However, it would appear that these regions tend also to be marginal with respect to wheat production and thus increased area estimation errors do not greatly influence the overall production estimation accuracy in the United States. The loss of segments resulting from cloud cover appears to be a random phenomenon that introduces no significant bias into the estimates. This loss does increase the variance of the estimates.
NASA Technical Reports Server (NTRS)
Drinkwater, Mark R.
1991-01-01
Pulse-limited, airborne radar data taken in June and July 1984 with a 13.8-GHz altimeter over the Fram Strait marginal ice zone are analyzed with the aid of large-format aerial photography, airborne synthetic aperture radar data, and surface observations. Variations in the radar return pulse waveforms are quantified and correlated with ice properties recorded during the Marginal Ice Zone Experiment. Results indicate that the wide-beam altimeter is a flexible instrument, capable of identifying the ice edge with a high degree of accuracy, calculating the ice concentration, and discriminating a number of different ice classes. This suggests that microwave radar altimeters have a sensitivity to sea ice which has not yet been fully exploited. When fused with SSM/I, AVHRR and ERS-1 synthetic aperture radar imagery, future ERS-1 altimeter data are expected to provide some missing pieces to the sea ice geophysics puzzle.
Homsy, Foudda R; Özcan, Mutlu; Khoury, Marwan; Majzoub, Zeina A K
2018-05-01
The subtractive and additive computer-aided design and computer-aided manufacturing (CAD-CAM) of lithium disilicate partial coverage restorations is poorly documented. The purpose of this in vitro study was to compare the marginal and internal fit accuracy of lithium disilicate glass-ceramic inlays fabricated with conventional, milled, and 3-dimensional (3D) printed wax patterns. A dentoform mandibular first molar was prepared for a mesio-occlusal ceramic inlay. Five groups of 15 inlays were obtained through conventional impression and manual wax pattern (group CICW); conventional impression, laboratory scanning of the stone die, CAD-CAM milled wax blanks (group CIDW) or 3D printed wax patterns (group CI3DW); and scanning of the master preparation with intraoral scanner and CAD-CAM milled (group DSDW) or 3D printed wax patterns (group DS3DW). The same design was used to produce the wax patterns in the last 4 groups. The replica technique was used to measure marginal and internal adaptation by using stereomicroscopy. Mixed-model ANOVA was used to assess differences according to the groups and discrepancy location (α=.05). Group DSDW showed the smallest marginal discrepancy (24.3 μm) compared with those of groups CICW (45.1 μm), CIDW (33.7 μm), CI3DW (39.8 μm), and DS3DW (39.7 μm) (P<.001). No statistically significant differences were detected among groups CICW, CIDW, CI3DW, and DS3DW relative to the marginal discrepancy. The internal discrepancy was significantly larger than the marginal discrepancy within all groups (P<.001). Lithium disilicate glass-ceramic inlays produced from digital scans and subtractive milling of wax patterns resulted in better marginal and internal fit accuracy than either conventional impression/fabrication or additive 3D manufacturing. Three-dimensional printed wax patterns yielded fit values similar to those of the conventionally waxed inlays. Copyright © 2017 Editorial Council for the Journal of Prosthetic Dentistry. Published by Elsevier Inc. All rights reserved.
Independent Predictors of Prognosis Based on Oral Cavity Squamous Cell Carcinoma Surgical Margins.
Buchakjian, Marisa R; Ginader, Timothy; Tasche, Kendall K; Pagedar, Nitin A; Smith, Brian J; Sperry, Steven M
2018-05-01
Objective To conduct a multivariate analysis of a large cohort of oral cavity squamous cell carcinoma (OCSCC) cases for independent predictors of local recurrence (LR) and overall survival (OS), with emphasis on the relationship between (1) prognosis and (2) main specimen permanent margins and intraoperative tumor bed frozen margins. Study Design Retrospective cohort study. Setting Tertiary academic head and neck cancer program. Subjects and Methods This study included 426 patients treated with OCSCC resection between 2005 and 2014 at University of Iowa Hospitals and Clinics. Patients underwent excision of OCSCC with intraoperative tumor bed frozen margin sampling and main specimen permanent margin assessment. Multivariate analysis of the data set to predict LR and OS was performed. Results Independent predictors of LR included nodal involvement, histologic grade, and main specimen permanent margin status. Specifically, the presence of a positive margin (odds ratio, 6.21; 95% CI, 3.3-11.9) or <1-mm/carcinoma in situ margin (odds ratio, 2.41; 95% CI, 1.19-4.87) on the main specimen was an independent predictor of LR, whereas intraoperative tumor bed margins were not predictive of LR on multivariate analysis. Similarly, independent predictors of OS on multivariate analysis included nodal involvement, extracapsular extension, and a positive main specimen margin. Tumor bed margins did not independently predict OS. Conclusion The main specimen margin is a strong independent predictor of LR and OS on multivariate analysis. Intraoperative tumor bed frozen margins do not independently predict prognosis. We conclude that emphasis should be placed on evaluating the main specimen margins when estimating prognosis after OCSCC resection.
Aranda Yus, Estefanía; Cantarell, Josep Maria Anglada; Miñarro Alonso, Antonio
2018-06-01
To determine the discrepancy in monolithic zirconium dioxide crowns made with computer-aided design and computer-aided manufacturing (CAD/CAM) systems by comparing scans of silicone impressions and of master casts. From a Cr-Co master die of a first upper left molar, 30 silicone impressions were taken. The 30 silicone impressions were scanned with the laboratory scanner, thus obtaining 30 milled monolithic yttrium stabilized zirconium dioxide (YSZD) crowns (the silicone group). They were poured and the working models were scanned, obtaining 30 milled monolithic yttrium stabilized zirconium dioxide (YSZD) crowns (the plaster group). Three predetermined points were analyzed in each side of the crown (Mesial, Distal ,Vestibular and Palatal), and the marginal fit was evaluated with SEM (×600). The response variable is the discrepancy from the master model. A repeated measures ANOVA with two within subject factors was performed to study significance of main factors and interaction. Mean marginal discrepancy was 22.42±35.65 µm in the silicone group and 8.94±14.69 µm in the plaster group. The statistical analysis showed significant differences between the two groups and also among the four aspects. Interaction was also significant ( P =.02). The mean marginal fit values of the two groups were within the clinically acceptable values. Significant differences were found between the groups according to the aspects studied. Various factors influenced the accuracy of digitizing, such as the design, the geometry, and the preparation guidance, as well as the texture, roughness and the color of the scanned material.
Mueller, Jenna L.; Harmany, Zachary T.; Mito, Jeffrey K.; Kennedy, Stephanie A.; Kim, Yongbaek; Dodd, Leslie; Geradts, Joseph; Kirsch, David G.; Willett, Rebecca M.; Brown, J. Quincy; Ramanujam, Nimmi
2013-01-01
Purpose To develop a robust tool for quantitative in situ pathology that allows visualization of heterogeneous tissue morphology and segmentation and quantification of image features. Materials and Methods Tissue excised from a genetically engineered mouse model of sarcoma was imaged using a subcellular resolution microendoscope after topical application of a fluorescent anatomical contrast agent: acriflavine. An algorithm based on sparse component analysis (SCA) and the circle transform (CT) was developed for image segmentation and quantification of distinct tissue types. The accuracy of our approach was quantified through simulations of tumor and muscle images. Specifically, tumor, muscle, and tumor+muscle tissue images were simulated because these tissue types were most commonly observed in sarcoma margins. Simulations were based on tissue characteristics observed in pathology slides. The potential clinical utility of our approach was evaluated by imaging excised margins and the tumor bed in a cohort of mice after surgical resection of sarcoma. Results Simulation experiments revealed that SCA+CT achieved the lowest errors for larger nuclear sizes and for higher contrast ratios (nuclei intensity/background intensity). For imaging of tumor margins, SCA+CT effectively isolated nuclei from tumor, muscle, adipose, and tumor+muscle tissue types. Differences in density were correctly identified with SCA+CT in a cohort of ex vivo and in vivo images, thus illustrating the diagnostic potential of our approach. Conclusion The combination of a subcellular-resolution microendoscope, acriflavine staining, and SCA+CT can be used to accurately isolate nuclei and quantify their density in anatomical images of heterogeneous tissue. PMID:23824589
Mueller, Jenna L; Harmany, Zachary T; Mito, Jeffrey K; Kennedy, Stephanie A; Kim, Yongbaek; Dodd, Leslie; Geradts, Joseph; Kirsch, David G; Willett, Rebecca M; Brown, J Quincy; Ramanujam, Nimmi
2013-01-01
To develop a robust tool for quantitative in situ pathology that allows visualization of heterogeneous tissue morphology and segmentation and quantification of image features. TISSUE EXCISED FROM A GENETICALLY ENGINEERED MOUSE MODEL OF SARCOMA WAS IMAGED USING A SUBCELLULAR RESOLUTION MICROENDOSCOPE AFTER TOPICAL APPLICATION OF A FLUORESCENT ANATOMICAL CONTRAST AGENT: acriflavine. An algorithm based on sparse component analysis (SCA) and the circle transform (CT) was developed for image segmentation and quantification of distinct tissue types. The accuracy of our approach was quantified through simulations of tumor and muscle images. Specifically, tumor, muscle, and tumor+muscle tissue images were simulated because these tissue types were most commonly observed in sarcoma margins. Simulations were based on tissue characteristics observed in pathology slides. The potential clinical utility of our approach was evaluated by imaging excised margins and the tumor bed in a cohort of mice after surgical resection of sarcoma. Simulation experiments revealed that SCA+CT achieved the lowest errors for larger nuclear sizes and for higher contrast ratios (nuclei intensity/background intensity). For imaging of tumor margins, SCA+CT effectively isolated nuclei from tumor, muscle, adipose, and tumor+muscle tissue types. Differences in density were correctly identified with SCA+CT in a cohort of ex vivo and in vivo images, thus illustrating the diagnostic potential of our approach. The combination of a subcellular-resolution microendoscope, acriflavine staining, and SCA+CT can be used to accurately isolate nuclei and quantify their density in anatomical images of heterogeneous tissue.
NASA Astrophysics Data System (ADS)
Luiza Bondar, M.; Hoogeman, Mischa; Schillemans, Wilco; Heijmen, Ben
2013-08-01
For online adaptive radiotherapy of cervical cancer, fast and accurate image segmentation is required to facilitate daily treatment adaptation. Our aim was twofold: (1) to test and compare three intra-patient automated segmentation methods for the cervix-uterus structure in CT-images and (2) to improve the segmentation accuracy by including prior knowledge on the daily bladder volume or on the daily coordinates of implanted fiducial markers. The tested methods were: shape deformation (SD) and atlas-based segmentation (ABAS) using two non-rigid registration methods: demons and a hierarchical algorithm. Tests on 102 CT-scans of 13 patients demonstrated that the segmentation accuracy significantly increased by including the bladder volume predicted with a simple 1D model based on a manually defined bladder top. Moreover, manually identified implanted fiducial markers significantly improved the accuracy of the SD method. For patients with large cervix-uterus volume regression, the use of CT-data acquired toward the end of the treatment was required to improve segmentation accuracy. Including prior knowledge, the segmentation results of SD (Dice similarity coefficient 85 ± 6%, error margin 2.2 ± 2.3 mm, average time around 1 min) and of ABAS using hierarchical non-rigid registration (Dice 82 ± 10%, error margin 3.1 ± 2.3 mm, average time around 30 s) support their use for image guided online adaptive radiotherapy of cervical cancer.
Bondar, M Luiza; Hoogeman, Mischa; Schillemans, Wilco; Heijmen, Ben
2013-08-07
For online adaptive radiotherapy of cervical cancer, fast and accurate image segmentation is required to facilitate daily treatment adaptation. Our aim was twofold: (1) to test and compare three intra-patient automated segmentation methods for the cervix-uterus structure in CT-images and (2) to improve the segmentation accuracy by including prior knowledge on the daily bladder volume or on the daily coordinates of implanted fiducial markers. The tested methods were: shape deformation (SD) and atlas-based segmentation (ABAS) using two non-rigid registration methods: demons and a hierarchical algorithm. Tests on 102 CT-scans of 13 patients demonstrated that the segmentation accuracy significantly increased by including the bladder volume predicted with a simple 1D model based on a manually defined bladder top. Moreover, manually identified implanted fiducial markers significantly improved the accuracy of the SD method. For patients with large cervix-uterus volume regression, the use of CT-data acquired toward the end of the treatment was required to improve segmentation accuracy. Including prior knowledge, the segmentation results of SD (Dice similarity coefficient 85 ± 6%, error margin 2.2 ± 2.3 mm, average time around 1 min) and of ABAS using hierarchical non-rigid registration (Dice 82 ± 10%, error margin 3.1 ± 2.3 mm, average time around 30 s) support their use for image guided online adaptive radiotherapy of cervical cancer.
Sun, LiJun; Hwang, Hyeon-Shik; Lee, Kyung-Min
2018-03-01
The purpose of this study was to examine changes in registration accuracy after including occlusal surface and incisal edge areas in addition to the buccal surface when integrating laser-scanned and maxillofacial cone-beam computed tomography (CBCT) dental images. CBCT scans and maxillary dental casts were obtained from 30 patients. Three methods were used to integrate the images: R1, only the buccal and labial surfaces were used; R2, the incisal edges of the anterior teeth and the buccal and distal marginal ridges of the second molars were used; and R3, labial surfaces, including incisal edges of anterior teeth, and buccal surfaces, including buccal and distal marginal ridges of the second molars, were used. Differences between the 2 images were evaluated by color-mapping methods and average surface distances by measuring the 3-dimensional Euclidean distances between the surface points on the 2 images. The R1 method showed more discrepancies between the laser-scanned and CBCT images than did the other methods. The R2 method did not show a significant difference in registration accuracy compared with the R3 method. The results of this study indicate that accuracy when integrating laser-scanned dental images into maxillofacial CBCT images can be increased by including occlusal surface and incisal edge areas as registration areas. Copyright © 2017 American Association of Orthodontists. Published by Elsevier Inc. All rights reserved.
Tannamala, Pavan Kumar; Azhagarasan, Nagarasampatti Sivaprakasam; Shankar, K Chitra
2013-01-01
Conventional casting techniques following the manufacturers' recommendations are time consuming. Accelerated casting techniques have been reported, but their accuracy with base metal alloys has not been adequately studied. We measured the vertical marginal gap of nickel-chromium copings made by conventional and accelerated casting techniques and determined the clinical acceptability of the cast copings in this study. Experimental design, in vitro study, lab settings. Ten copings each were cast by conventional and accelerated casting techniques. All copings were identical, only their mold preparation schedules differed. Microscopic measurements were recorded at ×80 magnification on the perpendicular to the axial wall at four predetermined sites. The marginal gap values were evaluated by paired t test. The mean marginal gap by conventional technique (34.02 μm) is approximately 10 μm lesser than that of accelerated casting technique (44.62 μm). As the P value is less than 0.0001, there is highly significant difference between the two techniques with regard to vertical marginal gap. The accelerated casting technique is time saving and the marginal gap measured was within the clinically acceptable limits and could be an alternative to time-consuming conventional techniques.
Calvo-Ortega, Juan-Francisco; Hermida-López, Marcelino; Moragues-Femenía, Sandra; Pozo-Massó, Miquel; Casals-Farran, Joan
2017-03-01
To evaluate the spatial accuracy of a frameless cone-beam computed tomography (CBCT)-guided cranial radiosurgery (SRS) using an end-to-end (E2E) phantom test methodology. Five clinical SRS plans were mapped to an acrylic phantom containing a radiochromic film. The resulting phantom-based plans (E2E plans) were delivered four times. The phantom was setup on the treatment table with intentional misalignments, and CBCT-imaging was used to align it prior to E2E plan delivery. Comparisons (global gamma analysis) of the planned and delivered dose to the film were performed using a commercial triple-channel film dosimetry software. The necessary distance-to-agreement to achieve a 95% (DTA95) gamma passing rate for a fixed 3% dose difference provided an estimate of the spatial accuracy of CBCT-guided SRS. Systematic (∑) and random (σ) error components, as well as 95% confidence levels were derived for the DTA95 metric. The overall systematic spatial accuracy averaged over all tests was 1.4mm (SD: 0.2mm), with a corresponding 95% confidence level of 1.8mm. The systematic (Σ) and random (σ) spatial components of the accuracy derived from the E2E tests were 0.2mm and 0.8mm, respectively. The E2E methodology used in this study allowed an estimation of the spatial accuracy of our CBCT-guided SRS procedure. Subsequently, a PTV margin of 2.0mm is currently used in our department. Copyright © 2017 Associazione Italiana di Fisica Medica. Published by Elsevier Ltd. All rights reserved.
SU-E-T-573: The Robustness of a Combined Margin Recipe for Uncertainties During Radiotherapy
DOE Office of Scientific and Technical Information (OSTI.GOV)
Stroom, J; Vieira, S; Greco, C
2014-06-01
Purpose: To investigate the variability of a safety margin recipe that combines CTV and PTV margins quadratically, with several tumor, treatment, and user related factors. Methods: Margin recipes were calculated by monte-carlo simulations in 5 steps. 1. A spherical tumor with or without isotropic microscopic was irradiated with a 5 field dose plan2. PTV: Geometric uncertainties were introduced using systematic (Sgeo) and random (sgeo) standard deviations. CTV: Microscopic disease distribution was modelled by semi-gaussian (Smicro) with varying number of islets (Ni)3. For a specific uncertainty set (Sgeo, sgeo, Smicro(Ni)), margins were varied until pre-defined decrease in TCP or dose coveragemore » was fulfilled. 4. First, margin recipes were calculated for each of the three uncertainties separately. CTV and PTV recipes were then combined quadratically to yield a final recipe M(Sgeo, sgeo, Smicro(Ni)).5. The final M was verified by simultaneous simulations of the uncertainties.Now, M has been calculated for various changing parameters like margin criteria, penumbra steepness, islet radio-sensitivity, dose conformity, and number of fractions. We subsequently investigated A: whether the combined recipe still holds in all these situations, and B: what the margin variation was in all these cases. Results: We found that the accuracy of the combined margin recipes remains on average within 1mm for all situations, confirming the correctness of the quadratic addition. Depending on the specific parameter, margin factors could change such that margins change over 50%. Especially margin recipes based on TCP-criteria are more sensitive to more parameters than those based on purely geometric Dmin-criteria. Interestingly, measures taken to minimize treatment field sizes (by e.g. optimizing dose conformity) are counteracted by the requirement of larger margins to get the same tumor coverage. Conclusion: Margin recipes combining geometric and microscopic uncertainties quadratically are accurate under varying circumstances. However margins can change up to 50% for different situations.« less
NASA Astrophysics Data System (ADS)
Sousa, Maria A. Z.; Siqueira, Paula N.; Schiabel, Homero
2015-03-01
A large number of breast phantoms have been developed for conducting quality tests, characterization of imaging systems and computer aided diagnosis schemes, dosimetry and image perception. The realism of these phantoms is important for ensuring the accuracy of results and a greater range of applications. In this work, a developed phantom is considered proposing the use of PVC films for simulation of nodules inserted in the breast parenchyma designed for classification between malignant and benign signals according to the BI-RADS® standard. The investigation includes analysis of radiographic density, mass shape and its corresponding contour outlined by experienced radiologists. The material was cut based on lesions margins found in 44 clinical cases, which were divided between circumscribed and spiculated structures. Tests were performed to check the ability of the specialists in distinguishing the contour compared to actual cases while the shapes accuracy was determined quantitatively by evaluation metrics. Results showed the applicability of the chosen material creating image radiological patterns very similar to the actual ones.
Theoretical and Empirical Analysis of a Spatial EA Parallel Boosting Algorithm.
Kamath, Uday; Domeniconi, Carlotta; De Jong, Kenneth
2018-01-01
Many real-world problems involve massive amounts of data. Under these circumstances learning algorithms often become prohibitively expensive, making scalability a pressing issue to be addressed. A common approach is to perform sampling to reduce the size of the dataset and enable efficient learning. Alternatively, one customizes learning algorithms to achieve scalability. In either case, the key challenge is to obtain algorithmic efficiency without compromising the quality of the results. In this article we discuss a meta-learning algorithm (PSBML) that combines concepts from spatially structured evolutionary algorithms (SSEAs) with concepts from ensemble and boosting methodologies to achieve the desired scalability property. We present both theoretical and empirical analyses which show that PSBML preserves a critical property of boosting, specifically, convergence to a distribution centered around the margin. We then present additional empirical analyses showing that this meta-level algorithm provides a general and effective framework that can be used in combination with a variety of learning classifiers. We perform extensive experiments to investigate the trade-off achieved between scalability and accuracy, and robustness to noise, on both synthetic and real-world data. These empirical results corroborate our theoretical analysis, and demonstrate the potential of PSBML in achieving scalability without sacrificing accuracy.
Gonzalo, Esther; Suárez, Maria J; Serrano, Benjamin; Lozano, Jose F L
2009-12-01
Marginal discrepancies of zirconia posterior fixed dental prostheses (FDPs) fabricated using various systems have been assessed to determine the quality of the restorations and facilitate clinical use; however, studies are limited and results are ambiguous because of the sample sizes and measurement methods. The purpose of this in vitro study was to compare changes in marginal fit of posterior fixed dental prostheses of 3 zirconia systems manufactured using CAD/CAM technology and metal ceramic posterior fixed dental protheses fabricated with the conventional lost-wax technique, before and after cementation. Forty standardized master steel dies with 2 abutments simulating first mandibular premolars were fabricated to receive a posterior 3-unit FDP (from first molar to first premolar) and divided into 4 groups (n=10): Lava All-Ceramic System, Procera Bridge Zirconia, VITA In-Ceram 2000 YZ, and metal ceramic (control group). All FDPs were prepared for an internal space of 50 microm. The external marginal gap of the restorations was investigated by measuring 30 points in the middle of the buccal and lingual surfaces; therefore, 60 measurements per abutment were recorded. Measurements were made with an image analysis program on the master steel model before and after conventional cementation with a glass ionomer agent (Ketac Cem Easymix). The data obtained were statistically analyzed using 1-way ANOVA, Duncan's multiple range post hoc test, and Student's paired t test (alpha=.05). No significant differences in the vertical marginal fit before and after cementation were recorded for the analyzed groups. The marginal discrepancy of Procera abutments before and after cementation (9 +/-10 microm and 12 +/-9 microm, respectively) was less than that of the other groups. Significant differences (P=.001) were observed in marginal adaptation between Procera Bridge Zirconia and the other groups. The results of this study showed that cementation did not cause a significant increase in the vertical marginal discrepancies of the FDPs and that an internal space of 50 mum provided a high precision of fit of the restorations. The accuracy of fit achieved for the 3 zirconium oxide groups analyzed was within the range of clinical acceptance, and the discrepancies were lower than in the metal ceramic group. Procera Bridge Zirconia showed the lowest vertical discrepancies.
NASA Astrophysics Data System (ADS)
Basuyau, C.; Tiberi, C.; Leroy, S.; Stuart, G.; Al-Lazki, A.; Al-Toubi, K.; Ebinger, C.
2010-02-01
Gravity data and P-wave teleseismic traveltime residuals from 29 temporary broad-band stations spread over the northern margin of the Gulf of Aden (Dhofar region, Oman) were used to image lithospheric structure. We apply a linear relationship between density and velocity to provide consistent density and velocity models from mid-crust down to about 250 km depth. The accuracy of the resulting models is investigated through a series of synthetic tests. The analysis of our resulting models shows: (1) crustal heterogeneities that match the main geological features at the surface; (2) the gravity edge effect and disparity in anomaly depth locations for layers at 20 and 50 km; (3) two low-velocity anomalies along the continuation of Socotra-Hadbeen and Alula-Fartak fracture zones between 60 and 200 km depth; and (4) evidence for partial melting (3-6 per cent) within these two negative anomalies. We discuss the presence of partial melting in terms of interaction between the Sheba ridge melts and its along-axis segmentation.
Safety margins in older adults increase with improved control of a dynamic object
Hasson, Christopher J.; Sternad, Dagmar
2014-01-01
Older adults face decreasing motor capabilities due to pervasive neuromuscular degradations. As a consequence, errors in movement control increase. Thus, older individuals should maintain larger safety margins than younger adults. While this has been shown for object manipulation tasks, several reports on whole-body activities, such as posture and locomotion, demonstrate age-related reductions in safety margins. This is despite increased costs for control errors, such as a fall. We posit that this paradox could be explained by the dynamic challenge presented by the body or also an external object, and that age-related reductions in safety margins are in part due to a decreased ability to control dynamics. To test this conjecture we used a virtual ball-in-cup task that had challenging dynamics, yet afforded an explicit rendering of the physics and safety margin. The hypotheses were: (1) When manipulating an object with challenging dynamics, older adults have smaller safety margins than younger adults. (2) Older adults increase their safety margins with practice. Nine young and 10 healthy older adults practiced moving the virtual ball-in-cup to a target location in exactly 2 s. The accuracy and precision of the timing error quantified skill, and the ball energy relative to an escape threshold quantified the safety margin. Compared to the young adults, older adults had increased timing errors, greater variability, and decreased safety margins. With practice, both young and older adults improved their ability to control the object with decreased timing errors and variability, and increased their safety margins. These results suggest that safety margins are related to the ability to control dynamics, and may explain why in tasks with simple dynamics older adults use adequate safety margins, but in more complex tasks, safety margins may be inadequate. Further, the results indicate that task-specific training may improve safety margins in older adults. PMID:25071566
Svensson, W E; Pandian, A J; Hashimoto, H
2010-10-01
The aim of this study was to evaluate the use of vascular morphology, around and within the B-mode region of abnormality, for improving the diagnostic accuracy of two of the most common solid breast pathologies. The B-mode and Doppler images of 117 breast cancers and 366 fibroadenomas and lesions with a fibroadenoma-like appearance were reviewed retrospectively and the morphology of the vascular pattern was evaluated. The ratio of external to internal color Doppler, the external vascular pattern and the connecting vessels to internal vessels were assessed and differentiated into benign and malignant vascular patterns. These patterns were correlated with the histological diagnosis. Vascularity was demonstrated in 95 % of cancers and in 46 % of benign lesions with a trend to increasing vascularity in cancers. This provided poor specificity for excluding cancer in fibroadenomas. Variations in vascular pattern were recorded. The observed benign vascular patterns were avascularity, vascularity in the periphery and peripheral marginal vessels connecting with internal vascularity. The observed malignant vascular patterns were radially aligned external vessels with internal vessels being more numerous than external vessels which connected to radial vessels. (Fisher exact test p < 0.0001). Analysis of the vascular morphology improved the sensitivity for identifying cancers from 97 % (B-mode) to 99 % (B-mode and color Doppler) with a minimal reduction in specificity (93.7 to 92.6 %) or accuracy (94.6 to 94.2 %). The presence of vascularity within a lesion, by itself, is no longer a good predictor of malignancy because of the increase in Doppler sensitivity associated with improvements in ultrasound technology. The color Doppler ultrasound vascular pattern morphology improves the accuracy and sensitivity of B-mode image diagnosis, breast cancers and fibroadenomas with a minimal loss of specificity. Any breast lesion with radial rather than marginal connecting vessels should be regarded with suspicion. © Georg Thieme Verlag KG Stuttgart · New York.
NASA Astrophysics Data System (ADS)
Xu, Xiaochun; Kang, Soyoung; Navarro-Comes, Eric; Wang, Yu; Liu, Jonathan T. C.; Tichauer, Kenneth M.
2018-03-01
Intraoperative tumor/surgical margin assessment is required to achieve higher tumor resection rate in breast-conserving surgery. Though current histology provides incomparable accuracy in margin assessment, thin tissue sectioning and the limited field of view of microscopy makes histology too time-consuming for intraoperative applications. If thick tissue, wide-field imaging can provide an acceptable assessment of tumor cells at the surface of resected tissues, an intraoperative protocol can be developed to guide the surgery and provide immediate feedback for surgeons. Topical staining of margins with cancer-targeted molecular imaging agents has the potential to provide the sensitivity needed to see microscopic cancer on a wide-field image; however, diffusion and nonspecific retention of imaging agents in thick tissue can significantly diminish tumor contrast with conventional methods. Here, we present a mathematical model to accurately simulate nonspecific retention, binding, and diffusion of imaging agents in thick tissue topical staining to guide and optimize future thick tissue staining and imaging protocol. In order to verify the accuracy and applicability of the model, diffusion profiles of cancer targeted and untargeted (control) nanoparticles at different staining times in A431 tumor xenografts were acquired for model comparison and tuning. The initial findings suggest the existence of nonspecific retention in the tissue, especially at the tissue surface. The simulator can be used to compare the effect of nonspecific retention, receptor binding and diffusion under various conditions (tissue type, imaging agent) and provides optimal staining and imaging protocols for targeted and control imaging agent.
Giordano, Mauro; Ausiello, Pietro; Martorelli, Massimo; Sorrentino, Roberto
2012-09-01
To evaluate the reliability and accuracy of computer-designed surgical guides in osseointegrated oral implant rehabilitation. Six implant rehabilitations, with a total of 17 implants, were completed with computer-designed surgical guides, performed with the master model developed by muco-compressive and muco-static impressions. In the first case, the surgical guide had exclusively mucosal support, in the second case exclusively dental support. For all six cases computer-aided surgical planning was performed by virtual analyses with 3D models obtained by dental scan DICOM data. The accuracy and stability of implant osseointegration over two years post surgery was then evaluated with clinical and radiographic examinations. Radiographic examination, performed with digital acquisitions (RVG - Radio Video graph) and parallel techniques, allowed two-dimensional feedback with a margin of linear error of 10%. Implant osseointegration was recorded for all the examined rehabilitations. During the clinical and radiographic post-surgical assessments, over the following two years, the peri-implant bone level was found to be stable and without appearance of any complications. The margin of error recorded between pre-operative positions assigned by virtual analysis and the post-surgical digital radiographic observations was as low as 0.2mm. Computer-guided implant surgery can be very effective in oral rehabilitations, providing an opportunity for the surgeon: (a) to avoid the necessity of muco-periosteal detachments and then (b) to perform minimally invasive interventions, whenever appropriate, with a flapless approach. Copyright © 2012 Academy of Dental Materials. Published by Elsevier Ltd. All rights reserved.
Stachs, A.; Thi, A. Tra-Ha; Dieterich, M.; Stubert, J.; Hartmann, S.; Glass, Ä.; Reimer, T.; Gerber, B.
2015-01-01
Purpose: To evaluate the accuracy of axillary ultrasound (AUS) in detecting nodal metastasis in patients with early-stage breast cancer and to identify AUS features with high predictive power. Materials and Methods: Prospective single-center preliminary study in 105 patients with a primary diagnosis of breast cancer and clinically negative axilla. AUS was performed using a 12 MHz linear-array transducer before ultrasound-guided needle biopsy. Nodal characteristics (shape, longitudinal-transverse [LT] axis ratio, margins, cortical thickness, hyperechoic hilum) were correlated with histopathological nodal status after SLNB or axillary lymph node dissection (ALND). Results: Nodal metastases were present in 42/105 patients (40.0%). Univariate analyses showed that absence of hyperechoic hilum, round shape, LT axis ratio<2, sharp margins and cortical thickness>3 mm were associated with lymph node metastasis. Multivariate logistic regression analysis revealed cortical thickness > 3 mm as an independent predictive parameter for nodal involvement. Sensitivity, specificity, positive predictive value, negative predictive value and accuracy were 66.7, 74.6, 63.6, 77.0% and 71.4% respectively when cortical thickness > 3 mm was applied as the criterion for AUS positivity. Axillary tumor volume was low in patients with pT1/2 tumors and negative AUS, since only 3.2% of patients had > 2 metastatic lymph nodes. Conclusion: Cortical thickness>3 mm is a reliable predictor of nodal metastatic involvement. Negative AUS does not exclude lymph node metastases, but extensive axillary tumor volume is rare. PMID:27689144
A new portable vibrator for plaster pouring: effect on the marginal fit at cylinder-abutment
de ANDRADE, Pâmela Cândida Aires Ribas; LUTHI, Leonardo Flores; STANLEY, Kyle; CARDOSO, Antônio Carlos
2012-01-01
Objective The aim of this study was to test a new portable vibrator for plaster pouring (developed for this purpose), comparing the effect of its use on the accuracy of working cast of implant-supported restorations to the conventional vibrator. Material and methods From a master cast with 2 implants, 30 transfer moldings were made randomly and divided into three groups: Group I (GI): pouring performed in an outsourced dental laboratory with conventional plaster vibrator (10 casts), Group II (GII): pouring performed in the laboratory of the Federal University of Santa Catarina (UFSC) with conventional plaster vibrator (10 casts) and Group III (GIII): pouring performed with the portable vibrator fabricated for this study (10 casts). The position of the analogue and marginal adaptation of the infrastructure were verified by testing the single screw on the master model and on the working model. The measurement of misfit was blindly performed with a precision microscope and analyzing unit, Quadra-Check 200. The data were statistically analyzed by analysis of variance (ANOVA) and the Holm-Sidak test (α=0.05). Results Means±standard deviations were as follows: GI: 19.19±4.73 µm; GII: 21.72±5.41 µm; GIII: 13.5±2.39 µm (P<0.05), with GIII significantly lower as compared to the other groups. Conclusion Within the limitations of this study, it was concluded that a greater accuracy of working cast was achieved when a portable vibrator was used for casting molds. PMID:23138736
Bhaskaran, Eswaran; Azhagarasan, N S; Miglani, Saket; Ilango, T; Krishna, G Phani; Gajapathi, B
2013-09-01
Accuracy of the fit of the restoration has always remained as one of the primary factors in determining success of the restoration. A well fitting restoration needs to be accurate both along its margins and internal surface. This study was conducted to comparatively evaluate the marginal gap and internal gap of cobalt-chromium (Co-Cr) copings fabricated by conventional casting procedures and with direct metal laser sintering (DMLS) technique. Among the total of 30 test samples 10 cast copings were made from inlay casting wax and 10 from 3D printed resin pattern. 10 copings were obtained from DMLS technique. All the 30 test samples were then cemented sequentially on stainless steel model using pressure indicating paste and evaluated for vertical marginal gap in 8 predetermined reference areas. All copings were then removed and partially sectioned and cemented sequentially on same master model for evaluation of internal gap at 4 predetermined reference areas. Both marginal gap and internal gap were measured in microns using video measuring system (VMS2010F). The results obtained for both marginal and internal gap were statistically analyzed and the values fall within the clinically acceptable range. The DMLS technique had an edge over the other two techniques used, as it exhibited minimal gap in the marginal region which is an area of chief concern.
An algorithm of improving speech emotional perception for hearing aid
NASA Astrophysics Data System (ADS)
Xi, Ji; Liang, Ruiyu; Fei, Xianju
2017-07-01
In this paper, a speech emotion recognition (SER) algorithm was proposed to improve the emotional perception of hearing-impaired people. The algorithm utilizes multiple kernel technology to overcome the drawback of SVM: slow training speed. Firstly, in order to improve the adaptive performance of Gaussian Radial Basis Function (RBF), the parameter determining the nonlinear mapping was optimized on the basis of Kernel target alignment. Then, the obtained Kernel Function was used as the basis kernel of Multiple Kernel Learning (MKL) with slack variable that could solve the over-fitting problem. However, the slack variable also brings the error into the result. Therefore, a soft-margin MKL was proposed to balance the margin against the error. Moreover, the relatively iterative algorithm was used to solve the combination coefficients and hyper-plane equations. Experimental results show that the proposed algorithm can acquire an accuracy of 90% for five kinds of emotions including happiness, sadness, anger, fear and neutral. Compared with KPCA+CCA and PIM-FSVM, the proposed algorithm has the highest accuracy.
Multi-disciplinary optimization of aeroservoelastic systems
NASA Technical Reports Server (NTRS)
Karpel, Mordechay
1990-01-01
Efficient analytical and computational tools for simultaneous optimal design of the structural and control components of aeroservoelastic systems are presented. The optimization objective is to achieve aircraft performance requirements and sufficient flutter and control stability margins with a minimal weight penalty and without violating the design constraints. Analytical sensitivity derivatives facilitate an efficient optimization process which allows a relatively large number of design variables. Standard finite element and unsteady aerodynamic routines are used to construct a modal data base. Minimum State aerodynamic approximations and dynamic residualization methods are used to construct a high accuracy, low order aeroservoelastic model. Sensitivity derivatives of flutter dynamic pressure, control stability margins and control effectiveness with respect to structural and control design variables are presented. The performance requirements are utilized by equality constraints which affect the sensitivity derivatives. A gradient-based optimization algorithm is used to minimize an overall cost function. A realistic numerical example of a composite wing with four controls is used to demonstrate the modeling technique, the optimization process, and their accuracy and efficiency.
Multidisciplinary optimization of aeroservoelastic systems using reduced-size models
NASA Technical Reports Server (NTRS)
Karpel, Mordechay
1992-01-01
Efficient analytical and computational tools for simultaneous optimal design of the structural and control components of aeroservoelastic systems are presented. The optimization objective is to achieve aircraft performance requirements and sufficient flutter and control stability margins with a minimal weight penalty and without violating the design constraints. Analytical sensitivity derivatives facilitate an efficient optimization process which allows a relatively large number of design variables. Standard finite element and unsteady aerodynamic routines are used to construct a modal data base. Minimum State aerodynamic approximations and dynamic residualization methods are used to construct a high accuracy, low order aeroservoelastic model. Sensitivity derivatives of flutter dynamic pressure, control stability margins and control effectiveness with respect to structural and control design variables are presented. The performance requirements are utilized by equality constraints which affect the sensitivity derivatives. A gradient-based optimization algorithm is used to minimize an overall cost function. A realistic numerical example of a composite wing with four controls is used to demonstrate the modeling technique, the optimization process, and their accuracy and efficiency.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Chang, J; Dept of Radiation Oncology, New York Weill Cornell Medical Ctr, New York, NY
Purpose: To develop a generalized statistical model that incorporates the treatment uncertainty from the rotational error of single iso-center technique, and calculate the additional PTV (planning target volume) margin required to compensate for this error. Methods: The random vectors for setup and additional rotation errors in the three-dimensional (3D) patient coordinate system were assumed to follow the 3D independent normal distribution with zero mean, and standard deviations σx, σy, σz, for setup error and a uniform σR for rotational error. Both random vectors were summed, normalized and transformed to the spherical coordinates to derive the chi distribution with 3 degreesmore » of freedom for the radical distance ρ. PTV margin was determined using the critical value of this distribution for 0.05 significant level so that 95% of the time the treatment target would be covered by ρ. The additional PTV margin required to compensate for the rotational error was calculated as a function of σx, σy, σz and σR. Results: The effect of the rotational error is more pronounced for treatments that requires high accuracy/precision like stereotactic radiosurgery (SRS) or stereotactic body radiotherapy (SBRT). With a uniform 2mm PTV margin (or σx =σy=σz=0.7mm), a σR=0.32mm will decrease the PTV coverage from 95% to 90% of the time, or an additional 0.2mm PTV margin is needed to prevent this loss of coverage. If we choose 0.2 mm as the threshold, any σR>0.3mm will lead to an additional PTV margin that cannot be ignored, and the maximal σR that can be ignored is 0.0064 rad (or 0.37°) for iso-to-target distance=5cm, or 0.0032 rad (or 0.18°) for iso-to-target distance=10cm. Conclusions: The rotational error cannot be ignored for high-accuracy/-precision treatments like SRS/SBRT, particularly when the distance between the iso-center and target is large.« less
Alex, Deepa; Shetty, Y Bharath; Miranda, Glynis Anita; Prabhu, M Bharath; Karkera, Reshma
2015-01-01
Conventional investing and casting techniques are time-consuming and usually requires 2-4 h for completion. Accelerated nonstandard, casting techniques have been reported to achieve similar quality results in significantly less time, namely, in 30-40 min. During casting, it is essential to achieve compensation for the shrinkage of solidifying alloy by investment expansion. The metal casting ring restricts the thermal expansion of investment because the thermal expansion of the ring is lesser than that of the investment. The use of casting ring was challenged with the introduction of the ringless technique. A total of 40 test samples of nickel chromium (Ni-Cr) cast copings were obtained from the patterns fabricated using inlay casting wax. The 20 wax patterns were invested using metal ring and 20 wax patterns were invested using the ringless investment system. Of both the groups, 10 samples underwent conventional casting, and the other 10 underwent accelerated casting. The patterns were casted using the induction casting technique. All the test samples of cast copings were evaluated for vertical marginal gaps at four points on the die employing a stereo optical microscope. The vertical marginal discrepancy data obtained were tabulated. Mean and standard deviations were obtained. Vertical discrepancies were analyzed using analysis of variance and Tukey honestly significantly different. The data obtained were found to be very highly significant (P < 0.001). Mean vertical gap was the maximum for Group II (53.64 μm) followed by Group IV (47.62 μm), Group I (44.83 μm) and Group III (35.35 μm). The Ni-Cr cast copings fabricated with the conventional casting using ringless investment system showed significantly better marginal fit than that of cast copings fabricated from conventional and accelerated casting with metal ring investment and accelerated casting using ringless investment since those copings had shown the least vertical marginal discrepancies among the four methods evaluated in this study.
Clinician Assessment of the Driving Competence of Patients with Dementia
Ott, Brian R.; Anthony, David; Papandonatos, George D.; D’Abreu, Anelyssa; Burock, Jeffrey; Curtin, Alicia; Wu, Chuang-Kuo; Morris, John C.
2012-01-01
OBJECTIVES To determine the validity and reliability of clinician ratings of the driving competence of patients with mild dementia. DESIGN Observational study of a cross-section of drivers with mild dementia based on chart review by clinicians with varying types of expertise and experience. SETTING Outpatient dementia clinic. PARTICIPANTS Fifty dementia subjects from a longitudinal study of driving and dementia. MEASUREMENTS Each clinician reviewed information from the clinic charts and the first study visit. The clinician then rated the drivers as safe, marginal, or unsafe. A professional driving instructor compared these ratings with total driving scores on a standardized road test and categorical ratings of driving competence. Clinicians also completed a visual analog scale assessment of variables that led to their determinations of driving competence. RESULTS Accuracy of clinician ratings ranged from 62% to 78% for the instructor’s global rating of safe versus marginal or unsafe. In general, there was moderate accuracy and interrater reliability. Accuracy could have been improved in the least-accurate raters by greater attention to dementia duration and severity ratings, as well as less reliance on the history and physical examination. The most accurate predictors were clinicians specially trained in dementia assessment, who were not necessarily the most experienced in their years of clinical experience. CONCLUSION Although a clinician may be able to identify many potentially hazardous drivers, accuracy is insufficient to suggest that a clinician’s assessment alone is adequate to determine driving competence in those with mild dementia. PMID:15877559
Unified framework to evaluate panmixia and migration direction among multiple sampling locations.
Beerli, Peter; Palczewski, Michal
2010-05-01
For many biological investigations, groups of individuals are genetically sampled from several geographic locations. These sampling locations often do not reflect the genetic population structure. We describe a framework using marginal likelihoods to compare and order structured population models, such as testing whether the sampling locations belong to the same randomly mating population or comparing unidirectional and multidirectional gene flow models. In the context of inferences employing Markov chain Monte Carlo methods, the accuracy of the marginal likelihoods depends heavily on the approximation method used to calculate the marginal likelihood. Two methods, modified thermodynamic integration and a stabilized harmonic mean estimator, are compared. With finite Markov chain Monte Carlo run lengths, the harmonic mean estimator may not be consistent. Thermodynamic integration, in contrast, delivers considerably better estimates of the marginal likelihood. The choice of prior distributions does not influence the order and choice of the better models when the marginal likelihood is estimated using thermodynamic integration, whereas with the harmonic mean estimator the influence of the prior is pronounced and the order of the models changes. The approximation of marginal likelihood using thermodynamic integration in MIGRATE allows the evaluation of complex population genetic models, not only of whether sampling locations belong to a single panmictic population, but also of competing complex structured population models.
Optical assessment of tumor resection margins in the breast
Brown, J. Quincy; Bydlon, Torre M.; Richards, Lisa M.; Yu, Bing; Kennedy, Stephanie A.; Geradts, Joseph; Wilke, Lee G.; Junker, Marlee; Gallagher, Jennifer; Barry, William; Ramanujam, Nimmi
2011-01-01
Breast conserving surgery, in which the breast tumor and surrounding normal tissue are removed, is the primary mode of treatment for invasive and in situ carcinomas of the breast, conditions that affect nearly 200,000 women annually. Of these nearly 200,000 patients who undergo this surgical procedure, between 20–70% of them may undergo additional surgeries to remove tumor that was left behind in the first surgery, due to the lack of intra-operative tools which can detect whether the boundaries of the excised specimens are free from residual cancer. Optical techniques have many attractive attributes which may make them useful tools for intra-operative assessment of breast tumor resection margins. In this manuscript, we discuss clinical design criteria for intra-operative breast tumor margin assessment, and review optical techniques appied to this problem. In addition, we report on the development and clinical testing of quantitative diffuse reflectance imaging (Q-DRI) as a potential solution to this clinical need. Q-DRI is a spectral imaging tool which has been applied to 56 resection margins in 48 patients at Duke University Medical Center. Clear sources of contrast between cancerous and cancer-free resection margins were identified with the device, and resulted in an overall accuracy of 75% in detecting positive margins. PMID:21544237
Exploring diversity in ensemble classification: Applications in large area land cover mapping
NASA Astrophysics Data System (ADS)
Mellor, Andrew; Boukir, Samia
2017-07-01
Ensemble classifiers, such as random forests, are now commonly applied in the field of remote sensing, and have been shown to perform better than single classifier systems, resulting in reduced generalisation error. Diversity across the members of ensemble classifiers is known to have a strong influence on classification performance - whereby classifier errors are uncorrelated and more uniformly distributed across ensemble members. The relationship between ensemble diversity and classification performance has not yet been fully explored in the fields of information science and machine learning and has never been examined in the field of remote sensing. This study is a novel exploration of ensemble diversity and its link to classification performance, applied to a multi-class canopy cover classification problem using random forests and multisource remote sensing and ancillary GIS data, across seven million hectares of diverse dry-sclerophyll dominated public forests in Victoria Australia. A particular emphasis is placed on analysing the relationship between ensemble diversity and ensemble margin - two key concepts in ensemble learning. The main novelty of our work is on boosting diversity by emphasizing the contribution of lower margin instances used in the learning process. Exploring the influence of tree pruning on diversity is also a new empirical analysis that contributes to a better understanding of ensemble performance. Results reveal insights into the trade-off between ensemble classification accuracy and diversity, and through the ensemble margin, demonstrate how inducing diversity by targeting lower margin training samples is a means of achieving better classifier performance for more difficult or rarer classes and reducing information redundancy in classification problems. Our findings inform strategies for collecting training data and designing and parameterising ensemble classifiers, such as random forests. This is particularly important in large area remote sensing applications, for which training data is costly and resource intensive to collect.
Simulating the effect of non-linear mode coupling in cosmological parameter estimation
NASA Astrophysics Data System (ADS)
Kiessling, A.; Taylor, A. N.; Heavens, A. F.
2011-09-01
Fisher Information Matrix methods are commonly used in cosmology to estimate the accuracy that cosmological parameters can be measured with a given experiment and to optimize the design of experiments. However, the standard approach usually assumes both data and parameter estimates are Gaussian-distributed. Further, for survey forecasts and optimization it is usually assumed that the power-spectrum covariance matrix is diagonal in Fourier space. However, in the low-redshift Universe, non-linear mode coupling will tend to correlate small-scale power, moving information from lower to higher order moments of the field. This movement of information will change the predictions of cosmological parameter accuracy. In this paper we quantify this loss of information by comparing naïve Gaussian Fisher matrix forecasts with a maximum likelihood parameter estimation analysis of a suite of mock weak lensing catalogues derived from N-body simulations, based on the SUNGLASS pipeline, for a 2D and tomographic shear analysis of a Euclid-like survey. In both cases, we find that the 68 per cent confidence area of the Ωm-σ8 plane increases by a factor of 5. However, the marginal errors increase by just 20-40 per cent. We propose a new method to model the effects of non-linear shear-power mode coupling in the Fisher matrix by approximating the shear-power distribution as a multivariate Gaussian with a covariance matrix derived from the mock weak lensing survey. We find that this approximation can reproduce the 68 per cent confidence regions of the full maximum likelihood analysis in the Ωm-σ8 plane to high accuracy for both 2D and tomographic weak lensing surveys. Finally, we perform a multiparameter analysis of Ωm, σ8, h, ns, w0 and wa to compare the Gaussian and non-linear mode-coupled Fisher matrix contours. The 6D volume of the 1σ error contours for the non-linear Fisher analysis is a factor of 3 larger than for the Gaussian case, and the shape of the 68 per cent confidence volume is modified. We propose that future Fisher matrix estimates of cosmological parameter accuracies should include mode-coupling effects.
NASA Astrophysics Data System (ADS)
Gommes, Cedric J.
2010-03-01
Although water rockets are widely used to illustrate first year physics principles, accurate measurements show that they outperform the usual textbook analysis at the beginning of the thrust phase. This paper gives a more thorough analysis of this problem. It is shown that the air expansion in the rocket is accompanied by water vapor condensation, which provides an extra thrust; the downward acceleration of water within the rocket also contributes to the thrust, an effect that is negligible in other types of rockets; the apparent gravity resulting from the acceleration of the rocket contributes as much to water ejection as does the pressure difference between the inside and outside of the rocket; and the water flow is transient, which precludes the use of Bernoulli's equation. Although none of these effects is negligible, they mostly cancel each other, and the overall accuracy of the analysis is only marginally improved. There remains a difference between theory and experiment with water rockets.
Bounded Linear Stability Margin Analysis of Nonlinear Hybrid Adaptive Control
NASA Technical Reports Server (NTRS)
Nguyen, Nhan T.; Boskovic, Jovan D.
2008-01-01
This paper presents a bounded linear stability analysis for a hybrid adaptive control that blends both direct and indirect adaptive control. Stability and convergence of nonlinear adaptive control are analyzed using an approximate linear equivalent system. A stability margin analysis shows that a large adaptive gain can lead to a reduced phase margin. This method can enable metrics-driven adaptive control whereby the adaptive gain is adjusted to meet stability margin requirements.
Xie, Long; Shinohara, Russell T; Ittyerah, Ranjit; Kuijf, Hugo J; Pluta, John B; Blom, Kim; Kooistra, Minke; Reijmer, Yael D; Koek, Huiberdina L; Zwanenburg, Jaco J M; Wang, Hongzhi; Luijten, Peter R; Geerlings, Mirjam I; Das, Sandhitsu R; Biessels, Geert Jan; Wolk, David A; Yushkevich, Paul A; Wisse, Laura E M
2018-01-01
Multi-atlas segmentation, a popular technique implemented in the Automated Segmentation of Hippocampal Subfields (ASHS) software, utilizes multiple expert-labelled images ("atlases") to delineate medial temporal lobe substructures. This multi-atlas method is increasingly being employed in early Alzheimer's disease (AD) research, it is therefore becoming important to know how the construction of the atlas set in terms of proportions of controls and patients with mild cognitive impairment (MCI) and/or AD affects segmentation accuracy. To evaluate whether the proportion of controls in the training sets affects the segmentation accuracy of both controls and patients with MCI and/or early AD at 3T and 7T. We performed cross-validation experiments varying the proportion of control subjects in the training set, ranging from a patient-only to a control-only set. Segmentation accuracy of the test set was evaluated by the Dice similarity coeffiecient (DSC). A two-stage statistical analysis was applied to determine whether atlas composition is linked to segmentation accuracy in control subjects and patients, for 3T and 7T. The different atlas compositions did not significantly affect segmentation accuracy at 3T and for patients at 7T. For controls at 7T, including more control subjects in the training set significantly improves the segmentation accuracy, but only marginally, with the maximum of 0.0003 DSC improvement per percent increment of control subject in the training set. ASHS is robust in this study, and the results indicate that future studies investigating hippocampal subfields in early AD populations can be flexible in the selection of their atlas compositions.
Worst-Case Flutter Margins from F/A-18 Aircraft Aeroelastic Data
NASA Technical Reports Server (NTRS)
Lind, Rick; Brenner, Marty
1997-01-01
An approach for computing worst-case flutter margins has been formulated in a robust stability framework. Uncertainty operators are included with a linear model to describe modeling errors and flight variations. The structured singular value, micron, computes a stability margin which directly accounts for these uncertainties. This approach introduces a new method of computing flutter margins and an associated new parameter for describing these margins. The micron margins are robust margins which indicate worst-case stability estimates with respect to the defined uncertainty. Worst-case flutter margins are computed for the F/A-18 SRA using uncertainty sets generated by flight data analysis. The robust margins demonstrate flight conditions for flutter may lie closer to the flight envelope than previously estimated by p-k analysis.
Hsieh, Chi-Wen; Liu, Tzu-Chiang; Wang, Jui-Kai; Jong, Tai-Lang; Tiu, Chui-Mei
2011-08-01
The Tanner-Whitehouse III (TW3) method is popular for assessing children's bone age, but it is time-consuming in clinical settings; to simplify this, a grouped-TW algorithm (GTA) was developed. A total of 534 left-hand roentgenograms of subjects aged 2-15 years, including 270 training and 264 testing datasets, were evaluated by a senior pediatrician. Next, GTA was used to choose the appropriate candidate of radius, ulna, and short bones and to classify the bones into three groups by data mining. Group 1 was composed of the maturity pattern of the radius and the middle phalange of the third and fifth digits and three weights were obtained by data mining, yielding a result similar to that of TW3. Subsequently, new bone-age assessment tables were constructed for boys and girls by linear regression and fuzzy logic. In addition, the Bland-Altman plot was utilized to compare accuracy between the GTA, the Greulich-Pyle (GP), and the TW3 method. The relative accuracy between the GTA and the TW3 was 96.2% in boys and 95% in girls, with an error of 1 year, while that between the assessment results of the GP and TW3 was about 87%, with an error of 1 year. However, even if the three weights were not optimally processed, GTA yielded a marginal result with an accuracy of 78.2% in boys and 79.6% in girls. GTA can efficiently simplify the complexity of the TW3 method, while maintaining almost the same accuracy. The relative accuracy between the assessment results of GTA and GP can also be marginal. © 2011 The Authors. Pediatrics International © 2011 Japan Pediatric Society.
Ribeiro, J. D.; Franklin, J. C.; Fox, K. R.; Bentley, K. H.; Kleiman, E. M.; Chang, B. P.; Nock, M. K.
2016-01-01
Background A history of self-injurious thoughts and behaviors (SITBs) is consistently cited as one of the strongest predictors of future suicidal behavior. However, stark discrepancies in the literature raise questions about the true magnitude of these associations. The objective of this study is to examine the magnitude and clinical utility of the associations between SITBs and subsequent suicide ideation, attempts, and death. Method We searched PubMed, PsycInfo, and Google Scholar for papers published through December 2014. Inclusion required that studies include at least one longitudinal analysis predicting suicide ideation, attempts, or death using any SITB variable. We identified 2179 longitudinal studies; 172 met inclusion criteria. Results The most common outcome was suicide attempt (47.80%), followed by death (40.50%) and ideation (11.60%). Median follow-up was 52 months (mean = 82.52, s.d. = 102.29). Overall prediction was weak, with weighted mean odds ratios (ORs) of 2.07 [95% confidence interval (CI) 1.76–2.43] for ideation, 2.14 (95% CI 2.00–2.30) for attempts, and 1.54 (95% CI 1.39–1.71) for death. Adjusting for publication bias further reduced estimates. Diagnostic accuracy analyses indicated acceptable specificity (86–87%) and poor sensitivity (10–26%), with areas under the curve marginally above chance (0.60–0.62). Most risk factors generated OR estimates of <2.0 and no risk factor exceeded 4.5. Effects were consistent regardless of sample severity, sample age groups, or follow-up length. Conclusions Prior SITBs confer risk for later suicidal thoughts and behaviors. However, they only provide a marginal improvement in diagnostic accuracy above chance. Addressing gaps in study design, assessment, and underlying mechanisms may prove useful in improving prediction and prevention of suicidal thoughts and behaviors. PMID:26370729
DOE Office of Scientific and Technical Information (OSTI.GOV)
Mao, W; Hrycushko, B; Yan, Y
Purpose: Traditional external beam radiotherapy for cervical cancer requires setup by external skin marks. In order to improve treatment accuracy and reduce planning margin for more conformal therapy, it is essential to monitor tumor positions interfractionally and intrafractionally. We demonstrate feasibility of monitoring cervical tumor motion online using EPID imaging from Beam’s Eye View. Methods: Prior to treatment, 1∼2 cylindrical radio opaque markers were implanted into inferior aspect of cervix tumor. During external beam treatments on a Varian 2100C by 4-field 3D plans, treatment beam images were acquired continuously by an EPID. A Matlab program was developed to locate internalmore » markers on MV images. Based on 2D marker positions obtained from different treatment fields, their 3D positions were estimated for every treatment fraction. Results: There were 398 images acquired during different treatment fractions of three cervical cancer patients. Markers were successfully located on every frame of image at an analysis speed of about 1 second per frame. Intrafraction motions were evaluated by comparing marker positions relative to the position on the first frame of image. The maximum intrafraction motion of the markers was 1.6 mm. Interfraction motions were evaluated by comparing 3D marker positions at different treatment fractions. The maximum interfraction motion was up to 10 mm. Careful comparison found that this is due to patient positioning since the bony structures shifted with the markers. Conclusion: This method provides a cost-free and simple solution for online tumor tracking for cervical cancer treatment since it is feasible to acquire and export EPID images with fast analysis in real time. This method does not need any extra equipment or deliver extra dose to patients. The online tumor motion information will be very useful to reduce planning margins and improve treatment accuracy, which is particularly important for SBRT treatment with long delivery time.« less
Use of Empirical Estimates of Shrinkage in Multiple Regression: A Caution.
ERIC Educational Resources Information Center
Kromrey, Jeffrey D.; Hines, Constance V.
1995-01-01
The accuracy of four empirical techniques to estimate shrinkage in multiple regression was studied through Monte Carlo simulation. None of the techniques provided unbiased estimates of the population squared multiple correlation coefficient, but the normalized jackknife and bootstrap techniques demonstrated marginally acceptable performance with…
McGarraugh, Geoffrey
2010-01-01
Continuous glucose monitoring (CGM) devices available in the United States are approved for use as adjuncts to self-monitoring of blood glucose (SMBG); all CGM alarms require SMBG confirmation before treatment. In this report, an analysis method is proposed to determine the CGM threshold alarm accuracy required to eliminate SMBG confirmation. The proposed method builds on the Clinical and Laboratory Standards Institute (CLSI) guideline for evaluating CGM threshold alarms using data from an in-clinic study of subjects with type 1 diabetes. The CLSI method proposes a maximum time limit of +/-30 minutes for the detection of hypo- and hyperglycemic events but does not include limits for glucose measurement accuracy. The International Standards Organization (ISO) standard for SMBG glucose measurement accuracy (ISO 15197) is +/-15 mg/dl for glucose <75 mg/dl and +/-20% for glucose > or = 75 mg/dl. This standard was combined with the CLSI method to more completely characterize the accuracy of CGM alarms. Incorporating the ISO 15197 accuracy margins, FreeStyle Navigator CGM system alarms detected 70 mg/dl hypoglycemia within 30 minutes at a rate of 70.3%, with a false alarm rate of 11.4%. The device detected high glucose in the range of 140-300 mg/dl within 30 minutes at an average rate of 99.2%, with a false alarm rate of 2.1%. Self-monitoring of blood glucose confirmation is necessary for detecting and treating hypoglycemia with the FreeStyle Navigator CGM system, but at high glucose levels, SMBG confirmation adds little incremental value to CGM alarms. 2010 Diabetes Technology Society.
Wong, Kwok-Chuen; Sze, Kwan-Yik; Wong, Irene Oi-Ling; Wong, Chung-Ming; Kumta, Shekhar-Madhukar
2016-02-01
Inaccurate resection in pelvic tumors can result in compromised margins with increase local recurrence. Navigation-assisted and patient-specific instrument (PSI) techniques have recently been reported in assisting pelvic tumor surgery with the tendency of improving surgical accuracy. We examined and compared the accuracy of transferring a virtual pelvic resection plan to actual surgery using navigation-assisted or PSI technique in a cadaver study. We performed CT scan in twelve cadaveric bodies including whole pelvic bones. Either supraacetabular or partial acetabular resection was virtually planned in a hemipelvis using engineering software. The virtual resection plan was transferred to a CT-based navigation system or was used for design and fabrication of PSI. Pelvic resections were performed using navigation assistance in six cadavers and PSI in another six. Post-resection images were co-registered with preoperative planning for comparative analysis of resection accuracy in the two techniques. The mean average deviation error from the planned resection was no different ([Formula: see text]) for the navigation and the PSI groups: 1.9 versus 1.4 mm, respectively. The mean time required for the bone resection was greater ([Formula: see text]) for the navigation group than for the PSI group: 16.2 versus 1.1 min, respectively. In simulated periacetabular pelvic tumor resections, PSI technique enabled surgeons to reproduce the virtual surgical plan with similar accuracy but with less bone resection time when compared with navigation assistance. Further studies are required to investigate the clinical benefits of PSI technique in pelvic tumor surgery.
Bouhrara, Mustapha; Spencer, Richard G.
2015-01-01
Myelin water fraction (MWF) mapping with magnetic resonance imaging has led to the ability to directly observe myelination and demyelination in both the developing brain and in disease. Multicomponent driven equilibrium single pulse observation of T1 and T2 (mcDESPOT) has been proposed as a rapid approach for multicomponent relaxometry and has been applied to map MWF in human brain. However, even for the simplest two-pool signal model consisting of MWF and non-myelin-associated water, the dimensionality of the parameter space for obtaining MWF estimates remains high. This renders parameter estimation difficult, especially at low-to-moderate signal-to-noise ratios (SNR), due to the presence of local minima and the flatness of the fit residual energy surface used for parameter determination using conventional nonlinear least squares (NLLS)-based algorithms. In this study, we introduce three Bayesian approaches for analysis of the mcDESPOT signal model to determine MWF. Given the high dimensional nature of mcDESPOT signal model, and, thereby, the high dimensional marginalizations over nuisance parameters needed to derive the posterior probability distribution of MWF parameter, the introduced Bayesian analyses use different approaches to reduce the dimensionality of the parameter space. The first approach uses normalization by average signal amplitude, and assumes that noise can be accurately estimated from signal-free regions of the image. The second approach likewise uses average amplitude normalization, but incorporates a full treatment of noise as an unknown variable through marginalization. The third approach does not use amplitude normalization and incorporates marginalization over both noise and signal amplitude. Through extensive Monte Carlo numerical simulations and analysis of in-vivo human brain datasets exhibiting a range of SNR and spatial resolution, we demonstrated the markedly improved accuracy and precision in the estimation of MWF using these Bayesian methods as compared to the stochastic region contraction (SRC) implementation of NLLS. PMID:26499810
A binary search approach to whole-genome data analysis.
Brodsky, Leonid; Kogan, Simon; Benjacob, Eshel; Nevo, Eviatar
2010-09-28
A sequence analysis-oriented binary search-like algorithm was transformed to a sensitive and accurate analysis tool for processing whole-genome data. The advantage of the algorithm over previous methods is its ability to detect the margins of both short and long genome fragments, enriched by up-regulated signals, at equal accuracy. The score of an enriched genome fragment reflects the difference between the actual concentration of up-regulated signals in the fragment and the chromosome signal baseline. The "divide-and-conquer"-type algorithm detects a series of nonintersecting fragments of various lengths with locally optimal scores. The procedure is applied to detected fragments in a nested manner by recalculating the lower-than-baseline signals in the chromosome. The algorithm was applied to simulated whole-genome data, and its sensitivity/specificity were compared with those of several alternative algorithms. The algorithm was also tested with four biological tiling array datasets comprising Arabidopsis (i) expression and (ii) histone 3 lysine 27 trimethylation CHIP-on-chip datasets; Saccharomyces cerevisiae (iii) spliced intron data and (iv) chromatin remodeling factor binding sites. The analyses' results demonstrate the power of the algorithm in identifying both the short up-regulated fragments (such as exons and transcription factor binding sites) and the long--even moderately up-regulated zones--at their precise genome margins. The algorithm generates an accurate whole-genome landscape that could be used for cross-comparison of signals across the same genome in evolutionary and general genomic studies.
Ambient Ionization Mass Spectrometry for Cancer Diagnosis and Surgical Margin Evaluation
Ifa, Demian R.; Eberlin, Livia S.
2017-01-01
Background There is a clinical need for new technologies that would enable rapid disease diagnosis based on diagnostic molecular signatures. Ambient ionization mass spectrometry has revolutionized the means by which molecular information can be obtained from tissue samples in real time and with minimal sample pretreatment. New developments in ambient ionization techniques applied to clinical research suggest that ambient ionization mass spectrometry will soon become a routine medical tool for tissue diagnosis. Content This review summarizes the main developments in ambient ionization techniques applied to tissue analysis, with focus on desorption electrospray ionization mass spectrometry, probe electrospray ionization, touch spray, and rapid evaporative ionization mass spectrometry. We describe their applications to human cancer research and surgical margin evaluation, highlighting integrated approaches tested for ex vivo and in vivo human cancer tissue analysis. We also discuss the challenges for clinical implementation of these tools and offer perspectives on the future of the field. Summary A variety of studies have showcased the value of ambient ionization mass spectrometry for rapid and accurate cancer diagnosis. Small molecules have been identified as potential diagnostic biomarkers, including metabolites, fatty acids, and glycerophospholipids. Statistical analysis allows tissue discrimination with high accuracy rates (>95%) being common. This young field has challenges to overcome before it is ready to be broadly accepted as a medical tool for cancer diagnosis. Growing research in new, integrated ambient ionization mass spectrometry technologies and the ongoing improvements in the existing tools make this field very promising for future translation into the clinic. PMID:26555455
Chai, Xin; Wang, Qisong; Zhao, Yongping; Li, Yongqiang; Liu, Dan; Liu, Xin; Bai, Ou
2017-01-01
Electroencephalography (EEG)-based emotion recognition is an important element in psychiatric health diagnosis for patients. However, the underlying EEG sensor signals are always non-stationary if they are sampled from different experimental sessions or subjects. This results in the deterioration of the classification performance. Domain adaptation methods offer an effective way to reduce the discrepancy of marginal distribution. However, for EEG sensor signals, both marginal and conditional distributions may be mismatched. In addition, the existing domain adaptation strategies always require a high level of additional computation. To address this problem, a novel strategy named adaptive subspace feature matching (ASFM) is proposed in this paper in order to integrate both the marginal and conditional distributions within a unified framework (without any labeled samples from target subjects). Specifically, we develop a linear transformation function which matches the marginal distributions of the source and target subspaces without a regularization term. This significantly decreases the time complexity of our domain adaptation procedure. As a result, both marginal and conditional distribution discrepancies between the source domain and unlabeled target domain can be reduced, and logistic regression (LR) can be applied to the new source domain in order to train a classifier for use in the target domain, since the aligned source domain follows a distribution which is similar to that of the target domain. We compare our ASFM method with six typical approaches using a public EEG dataset with three affective states: positive, neutral, and negative. Both offline and online evaluations were performed. The subject-to-subject offline experimental results demonstrate that our component achieves a mean accuracy and standard deviation of 80.46% and 6.84%, respectively, as compared with a state-of-the-art method, the subspace alignment auto-encoder (SAAE), which achieves values of 77.88% and 7.33% on average, respectively. For the online analysis, the average classification accuracy and standard deviation of ASFM in the subject-to-subject evaluation for all the 15 subjects in a dataset was 75.11% and 7.65%, respectively, gaining a significant performance improvement compared to the best baseline LR which achieves 56.38% and 7.48%, respectively. The experimental results confirm the effectiveness of the proposed method relative to state-of-the-art methods. Moreover, computational efficiency of the proposed ASFM method is much better than standard domain adaptation; if the numbers of training samples and test samples are controlled within certain range, it is suitable for real-time classification. It can be concluded that ASFM is a useful and effective tool for decreasing domain discrepancy and reducing performance degradation across subjects and sessions in the field of EEG-based emotion recognition. PMID:28467371
Chai, Xin; Wang, Qisong; Zhao, Yongping; Li, Yongqiang; Liu, Dan; Liu, Xin; Bai, Ou
2017-05-03
Electroencephalography (EEG)-based emotion recognition is an important element in psychiatric health diagnosis for patients. However, the underlying EEG sensor signals are always non-stationary if they are sampled from different experimental sessions or subjects. This results in the deterioration of the classification performance. Domain adaptation methods offer an effective way to reduce the discrepancy of marginal distribution. However, for EEG sensor signals, both marginal and conditional distributions may be mismatched. In addition, the existing domain adaptation strategies always require a high level of additional computation. To address this problem, a novel strategy named adaptive subspace feature matching (ASFM) is proposed in this paper in order to integrate both the marginal and conditional distributions within a unified framework (without any labeled samples from target subjects). Specifically, we develop a linear transformation function which matches the marginal distributions of the source and target subspaces without a regularization term. This significantly decreases the time complexity of our domain adaptation procedure. As a result, both marginal and conditional distribution discrepancies between the source domain and unlabeled target domain can be reduced, and logistic regression (LR) can be applied to the new source domain in order to train a classifier for use in the target domain, since the aligned source domain follows a distribution which is similar to that of the target domain. We compare our ASFM method with six typical approaches using a public EEG dataset with three affective states: positive, neutral, and negative. Both offline and online evaluations were performed. The subject-to-subject offline experimental results demonstrate that our component achieves a mean accuracy and standard deviation of 80.46% and 6.84%, respectively, as compared with a state-of-the-art method, the subspace alignment auto-encoder (SAAE), which achieves values of 77.88% and 7.33% on average, respectively. For the online analysis, the average classification accuracy and standard deviation of ASFM in the subject-to-subject evaluation for all the 15 subjects in a dataset was 75.11% and 7.65%, respectively, gaining a significant performance improvement compared to the best baseline LR which achieves 56.38% and 7.48%, respectively. The experimental results confirm the effectiveness of the proposed method relative to state-of-the-art methods. Moreover, computational efficiency of the proposed ASFM method is much better than standard domain adaptation; if the numbers of training samples and test samples are controlled within certain range, it is suitable for real-time classification. It can be concluded that ASFM is a useful and effective tool for decreasing domain discrepancy and reducing performance degradation across subjects and sessions in the field of EEG-based emotion recognition.
Anadioti, Evanthia; Aquilino, Steven A; Gratton, David G; Holloway, Julie A; Denry, Isabelle; Thomas, Geb W; Qian, Fang
2014-12-01
This in vitro study evaluated the 3D and 2D marginal fit of pressed and computer-aided-designed/computer-aided-manufactured (CAD/CAM) all-ceramic crowns made from digital and conventional impressions. A dentoform tooth (#30) was prepared for an all-ceramic crown (master die). Thirty type IV definitive casts were made from 30 polyvinyl siloxane (PVS) impressions. Thirty resin models were produced from thirty Lava Chairside Oral Scanner impressions. Thirty crowns were pressed in lithium disilicate (IPS e.max Press; 15/impression technique). Thirty crowns were milled from lithium disilicate blocks (IPS e.max CAD; 15/impression technique) using the E4D scanner and milling engine. The master die and the intaglio of the crowns were digitized using a 3D laser coordinate measurement machine with accuracy of ±0.00898 mm. For each specimen a separate data set was created for the Qualify 2012 software. The digital master die and the digital intaglio of each crown were merged using best-fitting alignment. An area above the margin with 0.75 mm occlusal-gingival width circumferentially was defined. The 3D marginal fit of each specimen was an average of all 3D gap values on that area. For the 2D measurements, the marginal gap was measured at two standardized points (on the margin and at 0.75 mm above the margin), from standardized facial-lingual and mesial-distal digitized sections. One-way ANOVA with post hoc Tukey's honestly significant difference and two-way ANOVA tests were used, separately, for statistical analysis of the 3D and 2D marginal data (alpha = 0.05). One-way ANOVA revealed that both 3D and 2D mean marginal gap for group A: PVS impression/IPS e.max Press (0.048 mm ± 0.009 and 0.040 mm ± 0.009) were significantly smaller than those obtained from the other three groups (p < 0.0001), while no significant differences were found among groups B: PVS impression/IPS e.max CAD (0.088 mm ± 0.024 and 0.076 mm ± 0.023), C: digital impression/IPS e.max Press (0.089 mm ± 0.020 and 0.075 mm ± 0.015) and D: digital impression/IPS e.max CAD (0.084 mm ± 0.021 and 0.074 mm ± 0.026). The results of two-way ANOVA revealed a significant interaction between impression techniques and crown fabrication methods for both 3D and 2D measurements. The combination of PVS impression method and press fabrication technique produced the most accurate 3D and 2D marginal fits. © 2014 by the American College of Prosthodontists.
Koo, Hyun Jung; Kim, Mi Young; Koo, Ja Hwan; Sung, Yu Sub; Jung, Jiwon; Kim, Sung-Han; Choi, Chang-Min; Kim, Hwa Jung
2017-01-01
Radiologists have used margin characteristics based on routine visual analysis; however, the attenuation changes at the margin of the lesion on CT images have not been quantitatively assessed. We established a CT-based margin analysis method by comparing a target lesion with normal lung attenuation, drawing a slope to represent the attenuation changes. This approach was applied to patients with invasive mucinous adenocarcinoma (n = 40) or bacterial pneumonia (n = 30). Correlations among multiple regions of interest (ROIs) were obtained using intraclass correlation coefficient (ICC) values. CT visual assessment, margin and texture parameters were compared for differentiating the two disease entities. The attenuation and margin parameters in multiple ROIs showed excellent ICC values. Attenuation slopes obtained at the margins revealed a difference between invasive mucinous adenocarcinoma and pneumonia (P<0.001), and mucinous adenocarcinoma produced a sharply declining attenuation slope. On multivariable logistic regression analysis, pneumonia had an ill-defined margin (odds ratio (OR), 4.84; 95% confidence interval (CI), 1.26-18.52; P = 0.02), ground-glass opacity (OR, 8.55; 95% CI, 2.09-34.95; P = 0.003), and gradually declining attenuation at the margin (OR, 12.63; 95% CI, 2.77-57.51, P = 0.001). CT-based margin analysis method has a potential to act as an imaging parameter for differentiating invasive mucinous adenocarcinoma and bacterial pneumonia.
What is the best surgical margin for a Basal cell carcinoma: a meta-analysis of the literature.
Gulleth, Yusuf; Goldberg, Nelson; Silverman, Ronald P; Gastman, Brian R
2010-10-01
Current management of basal cell carcinoma is surgical excision. Most resections use predetermined surgical margins. The basis of ideal resection margins is almost completely from retrospective data and mainly from small case series. This article presents a systematic analysis from a large pool of data to provide a better basis of determining ideal surgical margin. A systematic analysis was performed on data from 89 articles from a larger group of 973 articles selected from the PubMed database. Relevant inclusion and exclusion criteria were applied to all articles reviewed and the data were entered into a database for statistical analysis. The total number of lesions analyzed was 16,066; size ranged from 3 to 30 mm (mean, 11.7 ± 5.9 mm). Surgical margins ranged from 1 to 10 mm (mean, 3.9 ± 1.4 mm). Negative surgical margins ranged 45 to 100 percent (mean, 86 ± 12 percent). Recurrence rates for 5-, 4-, 3-, and 2-mm surgical margins were 0.39, 1.62, 2.56, and 3.96 percent, respectively. Pooled data for incompletely excised margins have an average recurrence rate of 27 percent. A 3-mm surgical margin can be safely used for nonmorpheaform basal cell carcinoma to attain 95 percent cure rates for lesions 2 cm or smaller. A positive pathologic margin has an average recurrence rate of 27 percent.
Efficacy of "Dimodent" sex predictive equation assessed in an Indian population.
Bharti, A; Angadi, P V; Kale, A D; Hallikerimath, S R
2011-07-01
Teeth are considered as a useful adjunct for sex assessment and may play an important role in constructing a post-mortem profile. The Dimodent method is based on the high degree of sex discrimination obtained with the mandibular canine and the high correlation coefficients between mandibular canine and lateral incisor mesiodistal (MD) and buccolingual (BL) dimensions. This has been evaluated in the French and Lebanese, but no study exists on its efficacy in Indians. Here, we have applied the 'Dimodent' equation on an Indian sample (100 males, 100 females; age range of 19-27yrs). Additionally, a population-specific Dimodent equation was derived using logistic regression analysis and applied to our sample. Also, the sex determination potential of MD and BL measurements of mandibular lateral incisors and canines, individually, was assessed. We found a poor sex assessment accuracy using the Dimodent equation of Fronty (34.5%) in our Indian sample, but the populationspecific Dimodent equation gave a better accuracy (72%).Thus, it appears that sexual dimorphism in teeth is population-specific; consequently the Dimodent equation has to be derived individually in different populations for use in sex assessment. The mesiodistal measurement of the mandibular canine alone gave a marginally higher accuracy (72.5%); therefore, we suggest the use of mandibular canines alone rather than the Dimodent method.
Wu, Jinshuang; Wang, Xianli; Xing, Helin; Guo, Tianwen; Dong, Chaofang
2017-01-01
This study investigated the mechanical properties and single crown accuracy of the tailor-made Fourth University Stomatology investment (FUS-invest) for casting titanium. Background. Current investment for casting titanium is not optimal for obtaining high-quality castings, and the commercially available titanium investment is costly. Methods. Titanium specimens were cast using the tailor-made FUS-invest. The mechanical properties were tested using a universal testing machine. Fractured castings were characterized by energy-dispersive spectroscopy. 19 titanium crowns were produced using FUS-invest and another 19 by Symbion. The accuracy of crowns was evaluated. Results. The mechanical properties of the titanium cast by FUS-invest were elastic modulus 125.6 ± 8.8 GPa, yield strength 567.5 ± 11.1 MPa, tensile strength 671.2 ± 15.6 MPa, and elongation 4.6 ± 0.2%. For marginal fit, no significant difference (P > 0.05) was found at four marker points of each group. For internal fit, no significant difference (P > 0.05) was found between two groups, whereas significant difference (P < 0.01) was found at different mark point of each group. Conclusions. The mechanical properties of titanium casted using FUS-invest fulfilled the ISO 9693 criteria. The marginal and internal fit of the titanium crowns using either the FUS-invest or Symbion were similar. PMID:28913355
NASA Astrophysics Data System (ADS)
Fei, Baowei; Lu, Guolan; Wang, Xu; Zhang, Hongzheng; Little, James V.; Magliocca, Kelly R.; Chen, Amy Y.
2017-02-01
We are developing label-free hyperspectral imaging (HSI) for tumor margin assessment. HSI data, hypercube (x,y,λ), consists of a series of high-resolution images of the same field of view that are acquired at different wavelengths. Every pixel on the HSI image has an optical spectrum. We developed preprocessing and classification methods for HSI data. We used spectral features from HSI data for the classification of cancer and benign tissue. We collected surgical tissue specimens from 16 human patients who underwent head and neck (H&N) cancer surgery. We acquired both HSI, autofluorescence images, and fluorescence images with 2-NBDG and proflavine from the specimens. Digitized histologic slides were examined by an H&N pathologist. The hyperspectral imaging and classification method was able to distinguish between cancer and normal tissue from oral cavity with an average accuracy of 90+/-8%, sensitivity of 89+/-9%, and specificity of 91+/-6%. For tissue specimens from the thyroid, the method achieved an average accuracy of 94+/-6%, sensitivity of 94+/-6%, and specificity of 95+/-6%. Hyperspectral imaging outperformed autofluorescence imaging or fluorescence imaging with vital dye (2-NBDG or proflavine). This study suggests that label-free hyperspectral imaging has great potential for tumor margin assessment in surgical tissue specimens of H&N cancer patients. Further development of the hyperspectral imaging technology is warranted for its application in image-guided surgery.
Schmidt, Brian M; McHugh, Jonathan B; Patel, Rajiv M; Wrobel, James S
2018-04-01
Osteomyelitis is common in diabetic foot infections and medical management can lead to poor outcomes. Surgical management involves sending histopathologic and microbiologic specimens which guides future intervention. We examined the effect of obtainment of surgical margins in patients undergoing forefoot amputations to identify patient characteristics associated with outcomes. Secondary aims included evaluating interobserver reliability of histopathologic data at both the distal-to and proximal-to surgical bone margin. Data were prospectively collected on 72 individuals and was pooled for analysis. Standardized method to retrieve intraoperative bone margins was established. A univariate analysis was performed. Negative outcomes, including major lower extremity amputation, wound dehiscence, reulceration, reamputation, or death were recorded. Viable proximal margins were obtained in 63 out of 72 cases (87.5%). Strong interobserver reliability of histopathology was recorded. Univariate analysis demonstrated preoperative platelets, albumin, probe-to-bone testing, absolute toe pressures, smaller wound surface area were associated with obtaining viable margins. Residual osteomyelitis resulted in readmission 2.6 times more often and more postoperative complications. Certain patients were significantly different in the viable margin group versus dirty margin group. High interobserver reliability was demonstrated. Obtainment of viable margins resulted in reduced rates of readmission and negative outcomes. Prognostic, Level I: Prospective.
Analysis of System Margins on Missions Utilizing Solar Electric Propulsion
NASA Technical Reports Server (NTRS)
Oh, David Y.; Landau, Damon; Randolph, Thomas; Timmerman, Paul; Chase, James; Sims, Jon; Kowalkowski, Theresa
2008-01-01
NASA's Jet Propulsion Laboratory has conducted a study focused on the analysis of appropriate margins for deep space missions using solar electric propulsion (SEP). The purpose of this study is to understand the links between disparate system margins (power, mass, thermal, etc.) and their impact on overall mission performance and robustness. It is determined that the various sources of uncertainty and risk associated with electric propulsion mission design can be summarized into three relatively independent parameters 1) EP Power Margin, 2) Propellant Margin and 3) Duty Cycle Margin. The overall relationship between these parameters and other major sources of uncertainty is presented. A detailed trajectory analysis is conducted to examine the impact that various assumptions related to power, duty cycle, destination, and thruster performance including missed thrust periods have on overall performance. Recommendations are presented for system margins for deep space missions utilizing solar electric propulsion.
High-resolution tree canopy mapping for New York City using LIDAR and object-based image analysis
NASA Astrophysics Data System (ADS)
MacFaden, Sean W.; O'Neil-Dunne, Jarlath P. M.; Royar, Anna R.; Lu, Jacqueline W. T.; Rundle, Andrew G.
2012-01-01
Urban tree canopy is widely believed to have myriad environmental, social, and human-health benefits, but a lack of precise canopy estimates has hindered quantification of these benefits in many municipalities. This problem was addressed for New York City using object-based image analysis (OBIA) to develop a comprehensive land-cover map, including tree canopy to the scale of individual trees. Mapping was performed using a rule-based expert system that relied primarily on high-resolution LIDAR, specifically its capacity for evaluating the height and texture of aboveground features. Multispectral imagery was also used, but shadowing and varying temporal conditions limited its utility. Contextual analysis was a key part of classification, distinguishing trees according to their physical and spectral properties as well as their relationships to adjacent, nonvegetated features. The automated product was extensively reviewed and edited via manual interpretation, and overall per-pixel accuracy of the final map was 96%. Although manual editing had only a marginal effect on accuracy despite requiring a majority of project effort, it maximized aesthetic quality and ensured the capture of small, isolated trees. Converting high-resolution LIDAR and imagery into usable information is a nontrivial exercise, requiring significant processing time and labor, but an expert system-based combination of OBIA and manual review was an effective method for fine-scale canopy mapping in a complex urban environment.
Legleiter, C.J.; Kinzel, P.J.; Overstreet, B.T.
2011-01-01
This study examined the possibility of mapping depth from optical image data in turbid, sediment-laden channels. Analysis of hyperspectral images from the Platte River indicated that depth retrieval in these environments is feasible, but might not be highly accurate. Four methods of calibrating image-derived depth estimates were evaluated. The first involved extracting image spectra at survey point locations throughout the reach. These paired observations of depth and reflectance were subjected to optimal band ratio analysis (OBRA) to relate (R2 = 0.596) a spectrally based quantity to flow depth. Two other methods were based on OBRA of data from individual cross sections. A fourth strategy used ground-based reflectance measurements to derive an OBRA relation (R2 = 0.944) that was then applied to the image. Depth retrieval accuracy was assessed by visually inspecting cross sections and calculating various error metrics. Calibration via field spectroscopy resulted in a shallow bias but provided relative accuracies similar to image-based methods. Reach-aggregated OBRA was marginally superior to calibrations based on individual cross sections, and depth retrieval accuracy varied considerably along each reach. Errors were lower and observed versus predicted regression R2 values higher for a relatively simple, deeper site than a shallower, braided reach; errors were 1/3 and 1/2 the mean depth for the two reaches. Bathymetric maps were coherent and hydraulically reasonable, however, and might be more reliable than implied by numerical metrics. As an example application, linear discriminant analysis was used to produce a series of depth threshold maps for characterizing shallow-water habitat for roosting cranes. ?? 2011 by the American Geophysical Union.
Legleiter, Carl J.; Kinzel, Paul J.; Overstreet, Brandon T.
2011-01-01
This study examined the possibility of mapping depth from optical image data in turbid, sediment-laden channels. Analysis of hyperspectral images from the Platte River indicated that depth retrieval in these environments is feasible, but might not be highly accurate. Four methods of calibrating image-derived depth estimates were evaluated. The first involved extracting image spectra at survey point locations throughout the reach. These paired observations of depth and reflectance were subjected to optimal band ratio analysis (OBRA) to relate (R2 = 0.596) a spectrally based quantity to flow depth. Two other methods were based on OBRA of data from individual cross sections. A fourth strategy used ground-based reflectance measurements to derive an OBRA relation (R2 = 0.944) that was then applied to the image. Depth retrieval accuracy was assessed by visually inspecting cross sections and calculating various error metrics. Calibration via field spectroscopy resulted in a shallow bias but provided relative accuracies similar to image-based methods. Reach-aggregated OBRA was marginally superior to calibrations based on individual cross sections, and depth retrieval accuracy varied considerably along each reach. Errors were lower and observed versus predicted regression R2 values higher for a relatively simple, deeper site than a shallower, braided reach; errors were 1/3 and 1/2 the mean depth for the two reaches. Bathymetric maps were coherent and hydraulically reasonable, however, and might be more reliable than implied by numerical metrics. As an example application, linear discriminant analysis was used to produce a series of depth threshold maps for characterizing shallow-water habitat for roosting cranes.
Accuracy of endoscopic and videofluoroscopic evaluations of swallowing for oropharyngeal dysphagia.
Giraldo-Cadavid, Luis Fernando; Leal-Leaño, Lorena Renata; Leon-Basantes, Guillermo Alfredo; Bastidas, Alirio Rodrigo; Garcia, Rafael; Ovalle, Sergio; Abondano-Garavito, Jorge E
2017-09-01
A systematic review and meta-analysis of the literature was conducted to compare the accuracy with which flexible endoscopic evaluation of swallowing (FEES) and videofluoroscopic swallowing study (VFSS) assessed oropharyngeal dysphagia in adults. PubMed, Embase, and the Latin American and Caribbean Health Sciences Literature (LILACS) database. A review of published studies was conducted in parallel by two groups of researchers. We evaluated the methodological quality, homogeneity, threshold effect, and publication bias. The results are presented as originally published, then with each test compared against the other as a reference and both compared against a composite reference standard, and then pooled using a random effects model. Software use consisted of Meta-DiSc and SPSS. The search yielded 5,697 articles. Fifty-two articles were reviewed in full text, and six articles were included in the meta-analysis. FEES showed greater sensitivity than VFSS for aspiration (0.88 vs. 0.77; P = .03), penetration (0.97 vs. 0.83; P = .0002), and laryngopharyngeal residues (0.97 vs. 0.80; P < .0001). Sensitivity to detect pharyngeal premature spillage was similar for both tests (VFSS: 0.80; FEES: 0.69; P = .28). The specificities of both tests were similar (range, 0.93-0.98). In the sensitivity analysis there were statistically significant differences between the tests regarding residues but only marginally significant differences regarding aspiration and penetration. FEES had a slight advantage over VFSS to detect aspiration, penetration, and residues. Prospective studies comparing both tests against an appropriate reference standard are needed to define which test has greater accuracy. 2a Laryngoscope, 127:2002-2010, 2017. © 2016 The American Laryngological, Rhinological and Otological Society, Inc.
Tyler, Susan; Truong, Pauline T; Lesperance, Mary; Nichol, Alan; Baliski, Chris; Warburton, Rebecca; Tyldesley, Scott
2018-03-13
The 2014 Society of Surgical Oncology-American Society for Radiation Oncology consensus suggested "no ink on tumor" is a sufficient surgical margin for invasive breast cancer treated with breast-conserving surgery (BCS). Whether close margins <2 mm are associated with inferior outcomes remains controversial. This study evaluated 10-year outcomes by margin status in a population-based cohort treated with BCS and adjuvant radiation therapy (RT). The subjects were 10,863 women with invasive cancer categorized as pT1 to T3, any N, and M0 referred from 2001 to 2011, an era in which the institutional policy was to re-excise close or positive margins, except in select cases. All women underwent BCS and whole-breast RT with or without boost RT. Local recurrence (LR) and breast cancer-specific survival (BCSS) were examined using competing-risk analysis in cohorts with negative (≥2 mm; n = 9241, 85%), close (<2 mm; n = 1310, 12%), or positive (tumor touching ink; n = 312, 3%) margins. Multivariable analysis and matched-pair analysis were performed. The median follow-up period was 8 years. Systemic therapy was used in 87% of patients. Boost RT was used in 34.1%, 76.9%, and 79.5% of patients with negative, close, and positive margins, respectively. In the negative, close, and positive margin cohorts, the 10-year cumulative incidence of LR was 1.8%, 2.0%, and 1.1%, respectively (P = .759). Corresponding BCSS estimates were 93.9%, 91.8%, and 87.9%, respectively (P < .001). On multivariable analysis, close margins were not associated with increased LR (hazard ratio, 1.25; 95% confidence interval 0.79-1.97; P = .350) or reduced BCSS (hazard ratio, 1.25; 95% confidence interval 0.98-1.58, P = .071) relative to negative margins. On matched-pair analysis, close margin cases had similar LR (P = .114) and BCSS (P = .100) to negative margin controls. Select cases with close or positive margins in this population-based analysis had similar LR and BCSS to cases with negative margins. While these findings do not endorse omitting re-excision for all cases, the data support a policy of accepting carefully selected cases with close margins for adjuvant RT without re-excision. Copyright © 2018 Elsevier Inc. All rights reserved.
Developing Typewriting Skill; Business Education: 7701.03.
ERIC Educational Resources Information Center
Abrams, Ruth
The junior high school student will type reports and themes, title pages, footnotes, bibliographies, carbon copies, headings, and subheadings; and use margins, pagination, and erasing. Emphasis is placed on speed and accuracy, the application of typewriting rules, and the advance applications of typewriting skills. A prerequisite for this course…
Estimation Methods for One-Parameter Testlet Models
ERIC Educational Resources Information Center
Jiao, Hong; Wang, Shudong; He, Wei
2013-01-01
This study demonstrated the equivalence between the Rasch testlet model and the three-level one-parameter testlet model and explored the Markov Chain Monte Carlo (MCMC) method for model parameter estimation in WINBUGS. The estimation accuracy from the MCMC method was compared with those from the marginalized maximum likelihood estimation (MMLE)…
Wang, Jane; Margonis, Georgios Antonios; Amini, Neda; Andreatos, Nikolaos; Yuan, Chunhui; Damaskos, Christos; Antoniou, Efstathios; Garmpis, Nikolaos; Buettner, Stefan; Barbon, Carlotta; Deshwar, Amar; He, Jin; Burkhart, Richard; Pawlik, Timothy M; Wolfgang, Christopher L; Weiss, Matthew J
2018-04-09
Varying definitions of resection margin clearance are currently employed among patients with colorectal cancer liver metastases (CRLM). Specifically, a microscopically positive margin (R1) has alternatively been equated with an involved margin (margin width = 0 mm) or a margin width < 1 mm. Consequently, patients with a margin width of 0-1 mm (sub-mm) are inconsistently classified in either the R0 or R1 categories, thus obscuring the prognostic implications of sub-mm margins. Six hundred thirty-three patients who underwent resection of CRLM were identified. Both R1 definitions were alternatively employed and multivariable analysis was used to determine the predictive power of each definition, as well as the prognostic implications of a sub-mm margin. Five hundred thirty-nine (85.2%) patients had a margin width ≥ 1 mm, 42 had a sub-mm margin width, and 52 had an involved margin (0 mm). A margin width ≥ 1 mm was associated with improved survival vs. a sub-mm margin (65 vs. 36 months; P = 0.03) or an involved margin (65 vs. 33 months; P < 0.001). No significant difference in survival was detected between patients with involved vs. sub-mm margins (P = 0.31). A sub-mm margin and an involved margin were both independent predictors of worse OS (HR 1.66, 1.04-2.67; P = 0.04, and HR 2.14, 1.46-3.16; P < 0.001, respectively) in multivariable analysis. Importantly, after combining the two definitions, patients with either an involved margin or a sub-mm margin were associated with worse OS in multivariable analysis (HR 1.94, 1.41-2.65; P < 0.001). Patients with involved or sub-mm margins demonstrated a similar inferior OS vs. patients with a margin width > 1 mm. Consequently, a uniform definition of R1 as a margin width < 1 mm should perhaps be employed by future studies.
Kraeima, Joep; Schepers, Rutger H; van Ooijen, Peter M A; Steenbakkers, Roel J H M; Roodenburg, Jan L N; Witjes, Max J H
2015-10-01
Three-dimensional (3D) virtual planning of reconstructive surgery, after resection, is a frequently used method for improving accuracy and predictability. However, when applied to malignant cases, the planning of the oncologic resection margins is difficult due to visualisation of tumours in the current 3D planning. Embedding tumour delineation on a magnetic resonance image, similar to the routinely performed radiotherapeutic contouring of tumours, is expected to provide better margin planning. A new software pathway was developed for embedding tumour delineation on magnetic resonance imaging (MRI) within the 3D virtual surgical planning. The software pathway was validated by the use of five bovine cadavers implanted with phantom tumour objects. MRI and computed tomography (CT) images were fused and the tumour was delineated using radiation oncology software. This data was converted to the 3D virtual planning software by means of a conversion algorithm. Tumour volumes and localization were determined in both software stages for comparison analysis. The approach was applied to three clinical cases. A conversion algorithm was developed to translate the tumour delineation data to the 3D virtual plan environment. The average difference in volume of the tumours was 1.7%. This study reports a validated software pathway, providing multi-modality image fusion for 3D virtual surgical planning. Copyright © 2015 European Association for Cranio-Maxillo-Facial Surgery. Published by Elsevier Ltd. All rights reserved.
Verhoeven, Karolien; Weltens, Caroline; Van den Heuvel, Frank
2015-01-01
Quantification of the setup errors is vital to define appropriate setup margins preventing geographical misses. The no‐action–level (NAL) correction protocol reduces the systematic setup errors and, hence, the setup margins. The manual entry of the setup corrections in the record‐and‐verify software, however, increases the susceptibility of the NAL protocol to human errors. Moreover, the impact of the skin mobility on the anteroposterior patient setup reproducibility in whole‐breast radiotherapy (WBRT) is unknown. In this study, we therefore investigated the potential of fixed vertical couch position‐based patient setup in WBRT. The possibility to introduce a threshold for correction of the systematic setup errors was also explored. We measured the anteroposterior, mediolateral, and superior–inferior setup errors during fractions 1–12 and weekly thereafter with tangential angled single modality paired imaging. These setup data were used to simulate the residual setup errors of the NAL protocol, the fixed vertical couch position protocol, and the fixed‐action–level protocol with different correction thresholds. Population statistics of the setup errors of 20 breast cancer patients and 20 breast cancer patients with additional regional lymph node (LN) irradiation were calculated to determine the setup margins of each off‐line correction protocol. Our data showed the potential of the fixed vertical couch position protocol to restrict the systematic and random anteroposterior residual setup errors to 1.8 mm and 2.2 mm, respectively. Compared to the NAL protocol, a correction threshold of 2.5 mm reduced the frequency of mediolateral and superior–inferior setup corrections with 40% and 63%, respectively. The implementation of the correction threshold did not deteriorate the accuracy of the off‐line setup correction compared to the NAL protocol. The combination of the fixed vertical couch position protocol, for correction of the anteroposterior setup error, and the fixed‐action–level protocol with 2.5 mm correction threshold, for correction of the mediolateral and the superior–inferior setup errors, was proved to provide adequate and comparable patient setup accuracy in WBRT and WBRT with additional LN irradiation. PACS numbers: 87.53.Kn, 87.57.‐s
Mai, Hang-Nga; Lee, Kyeong Eun; Lee, Kyu-Bok; Jeong, Seung-Mi; Lee, Seok-Jae; Lee, Cheong-Hee; An, Seo-Young; Lee, Du-Hyeong
2017-10-01
The purpose of this study was to evaluate the reliability of computer-aided replica technique (CART) by calculating its agreement with the replica technique (RT), using statistical agreement analysis. A prepared metal die and a metal crown were fabricated. The gap between the restoration and abutment was replicated using silicone indicator paste (n = 25). Gap measurements differed in the control (RT) and experimental (CART) groups. In the RT group, the silicone replica was manually sectioned, and the marginal and occlusal gaps were measured using a microscope. In the CART group, the gap was digitized using optical scanning and image superimposition, and the gaps were measured using a software program. The agreement between the measurement techniques was evaluated by using the 95% Bland-Altman limits of agreement and concordance correlation coefficients (CCC). The least acceptable CCC was 0.90. The RT and CART groups showed linear association, with a strong positive correlation in gap measurements, but without significant differences. The 95% limits of agreement between the paired gap measurements were 3.84% and 7.08% of the mean. The lower 95% confidence limits of CCC were 0.9676 and 0.9188 for the marginal and occlusal gap measurements, respectively, and the values were greater than the allowed limit. The CART is a reliable digital approach for evaluating the fit accuracy of fixed dental prostheses.
Prediction-Oriented Marker Selection (PROMISE): With Application to High-Dimensional Regression.
Kim, Soyeon; Baladandayuthapani, Veerabhadran; Lee, J Jack
2017-06-01
In personalized medicine, biomarkers are used to select therapies with the highest likelihood of success based on an individual patient's biomarker/genomic profile. Two goals are to choose important biomarkers that accurately predict treatment outcomes and to cull unimportant biomarkers to reduce the cost of biological and clinical verifications. These goals are challenging due to the high dimensionality of genomic data. Variable selection methods based on penalized regression (e.g., the lasso and elastic net) have yielded promising results. However, selecting the right amount of penalization is critical to simultaneously achieving these two goals. Standard approaches based on cross-validation (CV) typically provide high prediction accuracy with high true positive rates but at the cost of too many false positives. Alternatively, stability selection (SS) controls the number of false positives, but at the cost of yielding too few true positives. To circumvent these issues, we propose prediction-oriented marker selection (PROMISE), which combines SS with CV to conflate the advantages of both methods. Our application of PROMISE with the lasso and elastic net in data analysis shows that, compared to CV, PROMISE produces sparse solutions, few false positives, and small type I + type II error, and maintains good prediction accuracy, with a marginal decrease in the true positive rates. Compared to SS, PROMISE offers better prediction accuracy and true positive rates. In summary, PROMISE can be applied in many fields to select regularization parameters when the goals are to minimize false positives and maximize prediction accuracy.
Immunohistochemical analysis of an ectopic endometriosis in the uterine round ligament.
Terada, Shinichi; Miyata, Yachiyo; Nakazawa, Hiroaki; Higashimori, Takamitsu; Arai, Takanari; Kikuchi, Yuji; Nozaki, Motohiro
2006-09-09
A rare case of the inguinal endometriosis was reported with immunohistochemical analysis. A 28-year-old woman had a thumb-sized tumor in the right groin for two years with a gradual increase in size and pain. An operation revealed an elastic hard tumor with an unclear margin and adhesion to the uterine round ligament. The histology showed irregular proliferation of the endometrial glands and stroma. The glandular epithelium stained weakly positive against CD125 antibody and the stromal matrix stained strongly positive against CD10 antibody. The nucleus in both the epithelial and stromal cells stained strongly positive against progesterone and estrogen receptor antibodies, and the cytoplasm in both types of cells stained moderately positive against COX-2 (cyclooxygenase-2) antibody. In conclusion, the combination of estrogen or progesterone receptor antibody for the nucleus and CD10 or COX-2 antibody for the cytoplasm could enhance the accuracy of diagnosis for ectopic endometriosis.
Classification of Tidal Disruption Events Based on Stellar Orbital Properties
NASA Astrophysics Data System (ADS)
Hayasaki, Kimitake; Zhong, Shiyan; Li, Shuo; Berczik, Peter; Spurzem, Rainer
2018-03-01
We study the rates of tidal disruption of stars on bound to unbound orbits by intermediate-mass to supermassive black holes using high-accuracy direct N-body experiments. Stars from the star cluster approaching the black hole can have three types of orbit: eccentric, parabolic, and hyperbolic. Since the mass fallback rate shows different variabilities depending on the orbital type, we can classify tidal disruption events (TDEs) into three main categories: eccentric, parabolic, and hyperbolic. The respective TDEs are characterized by two critical values of the orbital eccentricity: the lower critical eccentricity is the one below which stars on eccentric orbits cause finite, intense accretion, and the upper critical eccentricity is the one above which stars on hyperbolic orbits cause no accretion. Moreover, we find that parabolic TDEs can be divided into three subclasses: precisely parabolic, marginally eccentric, and marginally hyperbolic. We analytically derive that the mass fallback rate of marginally eccentric TDEs can be flatter and slightly higher than the standard fallback rate proportional to t ‑5/3, whereas it can be flatter and lower for marginally hyperbolic TDEs. We confirm using N-body experiments that only a few eccentric, precisely parabolic, and hyperbolic TDEs can occur in a spherical stellar system with a single intermediate-mass to supermassive black hole. A substantial fraction of the stars approaching the black hole would cause marginally eccentric or marginally hyperbolic TDEs.
Bickford, Lissett R; Agollah, Germaine; Drezek, Rebekah; Yu, Tse-Kuan
2010-04-01
Obtaining negative margins is critical for breast cancer patients undergoing conservation therapy in order to reduce the reemergence of the original cancer. Currently, breast cancer tumor margins are examined in a pathology lab either while the patient is anesthetized or after the surgical procedure has been terminated. These current methods often result in cancer cells present at the surgical resection margin due to inadequate margin assessment at the point of care. Due to such limitations evident in current diagnoses, tools for increasing the accuracy and speed of tumor margin detection directly in the operating room are still needed. We are exploring the potential of using a nano-biophotonics system to facilitate intraoperative tumor margin assessment ex vivo at the cellular level. By combining bioconjugated silica-based gold nanoshells, which scatter light in the near-infrared, with a portable FDA-approved reflectance confocal microscope, we first validate the use of gold nanoshells as effective reflectance-based imaging probes by evaluating the contrast enhancement of three different HER2-overexpressing cell lines. Additionally, we demonstrate the ability to detect HER2-overexpressing cells in human tissue sections within 5 min of incubation time. This work supports the use of targeted silica-based gold nanoshells as potential real-time molecular probes for HER2-overexpression in human tissue.
Abutment Disconnection/Reconnection Affects Peri-implant Marginal Bone Levels: A Meta-Analysis.
Koutouzis, Theofilos; Gholami, Fatemeh; Reynolds, John; Lundgren, Tord; Kotsakis, Georgios A
Preclinical and clinical studies have shown that marginal bone loss can be secondary to repeated disconnection and reconnection of abutments that affect the peri-implant mucosal seal. The aim of this systematic review and meta-analysis was to evaluate the impact of abutment disconnections/reconnections on peri-implant marginal bone level changes. To address this question, two reviewers independently performed an electronic search of three major databases up to October 2015 complemented by manual searches. Eligible articles were selected on the basis of prespecified inclusion and exclusion criteria after a two-phase search strategy and assessed for risk of bias. A random-effects meta-analysis was performed for marginal bone loss. The authors initially identified 392 titles and abstracts. After evaluation, seven controlled clinical studies were included. Qualitative assessment of the articles revealed a trend toward protective marginal bone level preservation for implants with final abutment placement (FAP) at the time of implant placement compared with implants for which there were multiple abutment placements (MAP). The FAP group exhibited a marginal bone level change ranging from 0.08 to 0.34 mm, whereas the MAP group exhibited a marginal bone level change ranging from 0.09 to 0.55 mm. Meta-analysis of the seven studies reporting on 396 implants showed significantly greater bone loss in cases of multiple abutment disconnections/reconnections. The weighted mean difference in marginal bone loss was 0.19 mm (95% confidence interval, 0.06-0.32 mm), favoring bone preservation in the FAP group. Within the limitations of this meta-analysis, abutment disconnection and reconnection significantly affected peri-implant marginal bone levels. These findings pave the way for revisiting current restorative protocols at the restorative treatment planning stage to prevent incipient marginal bone loss.
Stafeev, A A; Zinov'ev, G I; Drozdov, D D
2015-01-01
The orthopedic restoration and related to its clinical stages (preparation, gingival retraction, impression) is often associated with complications which arise from the marginal gingiva. The technology of indirect ceramic restoration requires an assessment of the clinical and morphological parameters of periodontal tissues. The study outlines correlation between the type of periodontal histhology and inflammatory and degenerative complications that has been established after the analysis of morphofunctional state of periodontal tissue. Results of clinical studies and correlation analysis of clinical and morphological parameters of marginal gingiva has shown that important parameter influencing the choice of manufacturing technology are the position of restoration margin relatively to marginal gingiva and periodontal morphotype.
NASA Astrophysics Data System (ADS)
Hänsch, Ronny; Hellwich, Olaf
2018-04-01
Random Forests have continuously proven to be one of the most accurate, robust, as well as efficient methods for the supervised classification of images in general and polarimetric synthetic aperture radar data in particular. While the majority of previous work focus on improving classification accuracy, we aim for accelerating the training of the classifier as well as its usage during prediction while maintaining its accuracy. Unlike other approaches we mainly consider algorithmic changes to stay as much as possible independent of platform and programming language. The final model achieves an approximately 60 times faster training and a 500 times faster prediction, while the accuracy is only marginally decreased by roughly 1 %.
Lalande, David; Hodd, Jeffrey A; Brousseau, John S; Ramos, Van; Dunham, Daniel; Rueggeberg, Frederick
2017-10-14
Because crowns with open margins are a well-known problem and can lead to complications, it is important to assess the accuracy of margins resulting from the use of a new technique. Currently, data regarding the marginal fit of computer-aided design and computer-aided manufacturing (CAD-CAM) technology to fabricate a complete gold crown (CGC) from a castable acrylate resin polymer block are lacking. The purpose of this in vitro study was to compare marginal discrepancy widths of CGCs fabricated by using either conventional hand waxing or acrylate resin polymer blocks generated by using CAD-CAM technology. A plastic model of a first mandibular molar was prepared by using a 1-mm, rounded chamfer margin on the entire circumference of the tooth. The master die was duplicated 30 times, and 15 wax patterns were fabricated by using a manual waxing technique, and 15 were fabricated by using CAD-CAM technology. All patterns were invested and cast, and resulting CGCs were cemented on their respective die by using resin-modified glass ionomer cement. The specimens were then embedded in acrylic resin and sectioned buccolingually. The buccal and lingual marginal discrepancies of each sectioned portion were measured by using microscopy at ×50 magnification. Data were subjected to repeated measures 2-way ANOVA, by using the Tukey post hoc pairwise comparison test (α=.05). The factor of "technique" had no significant influence on marginal discrepancy measurement (P=.431), but a significant effect of "margin location" (P=.019) was noted. The confounding combination of factors was found to be significantly lower marginal discrepancy dimensions of the lingual margin discrepancy than on the buccal side by using CAD-CAM technology. The marginal discrepancy of CAD-CAM acrylate resin crowns was not significantly different from those made with a conventional manual method; however, lingual margin discrepancies present from CAD-CAM-prepared crowns were significantly less than those measured on the respective buccal surface. Copyright © 2017 Editorial Council for the Journal of Prosthetic Dentistry. Published by Elsevier Inc. All rights reserved.
Augmented reality in bone tumour resection: An experimental study.
Cho, H S; Park, Y K; Gupta, S; Yoon, C; Han, I; Kim, H-S; Choi, H; Hong, J
2017-03-01
We evaluated the accuracy of augmented reality (AR)-based navigation assistance through simulation of bone tumours in a pig femur model. We developed an AR-based navigation system for bone tumour resection, which could be used on a tablet PC. To simulate a bone tumour in the pig femur, a cortical window was made in the diaphysis and bone cement was inserted. A total of 133 pig femurs were used and tumour resection was simulated with AR-assisted resection (164 resection in 82 femurs, half by an orthropaedic oncology expert and half by an orthopaedic resident) and resection with the conventional method (82 resection in 41 femurs). In the conventional group, resection was performed after measuring the distance from the edge of the condyle to the expected resection margin with a ruler as per routine clinical practice. The mean error of 164 resections in 82 femurs in the AR group was 1.71 mm (0 to 6). The mean error of 82 resections in 41 femurs in the conventional resection group was 2.64 mm (0 to 11) (p < 0.05, one-way analysis of variance). The probabilities of a surgeon obtaining a 10 mm surgical margin with a 3 mm tolerance were 90.2% in AR-assisted resections, and 70.7% in conventional resections. We demonstrated that the accuracy of tumour resection was satisfactory with the help of the AR navigation system, with the tumour shown as a virtual template. In addition, this concept made the navigation system simple and available without additional cost or time. Cite this article: H. S. Cho, Y. K. Park, S. Gupta, C. Yoon, I. Han, H-S. Kim, H. Choi, J. Hong. Augmented reality in bone tumour resection: An experimental study. Bone Joint Res 2017;6:137-143. © 2017 Cho et al.
Augmented reality in bone tumour resection
Park, Y. K.; Gupta, S.; Yoon, C.; Han, I.; Kim, H-S.; Choi, H.; Hong, J.
2017-01-01
Objectives We evaluated the accuracy of augmented reality (AR)-based navigation assistance through simulation of bone tumours in a pig femur model. Methods We developed an AR-based navigation system for bone tumour resection, which could be used on a tablet PC. To simulate a bone tumour in the pig femur, a cortical window was made in the diaphysis and bone cement was inserted. A total of 133 pig femurs were used and tumour resection was simulated with AR-assisted resection (164 resection in 82 femurs, half by an orthropaedic oncology expert and half by an orthopaedic resident) and resection with the conventional method (82 resection in 41 femurs). In the conventional group, resection was performed after measuring the distance from the edge of the condyle to the expected resection margin with a ruler as per routine clinical practice. Results The mean error of 164 resections in 82 femurs in the AR group was 1.71 mm (0 to 6). The mean error of 82 resections in 41 femurs in the conventional resection group was 2.64 mm (0 to 11) (p < 0.05, one-way analysis of variance). The probabilities of a surgeon obtaining a 10 mm surgical margin with a 3 mm tolerance were 90.2% in AR-assisted resections, and 70.7% in conventional resections. Conclusion We demonstrated that the accuracy of tumour resection was satisfactory with the help of the AR navigation system, with the tumour shown as a virtual template. In addition, this concept made the navigation system simple and available without additional cost or time. Cite this article: H. S. Cho, Y. K. Park, S. Gupta, C. Yoon, I. Han, H-S. Kim, H. Choi, J. Hong. Augmented reality in bone tumour resection: An experimental study. Bone Joint Res 2017;6:137–143. PMID:28258117
Measurement system analysis of viscometers used for drilling mud characterization
NASA Astrophysics Data System (ADS)
Mat-Shayuti, M. S.; Adzhar, S. N.
2017-07-01
Viscometers in the Faculty of Chemical Engineering, University Teknologi MARA, are subject to heavy utilization from the members of the faculty. Due to doubts surrounding their result integrity and maintenance management, Measurement System Analysis was executed. 5 samples of drilling muds with varied barite content from 5 - 25 weight% were prepared and their rheological properties determined in 3 trials by 3 operators using the viscometers. Gage Linearity and Bias Study were performed using Minitab software and the result shows high biases in the range of 19.2% to 38.7%, with non-linear trend along the span of measurements. Gage Repeatability & Reproducibility (Nested) analysis later produces Percent Repeatability & Reproducibility more than 7.7% and Percent Tolerance above 30%. Lastly, good and marginal Distinct Categories output are seen among the results. Despite acceptable performance of the measurement system in Distinct Categories, the poor results in accuracy, linearity, and Percent Repeatability & Reproducibility render the gage generally not capable. Improvement to the measurement system is imminent.
Boughey, Judy C; Keeney, Gary L; Radensky, Paul; Song, Christine P; Habermann, Elizabeth B
2016-04-01
In the current health care environment, cost effectiveness is critically important in policy setting and care of patients. This study performed a health economic analysis to assess the implications to providers and payers of expanding the use of frozen section margin analysis to minimize reoperations for patients undergoing breast cancer lumpectomy. A health care economic impact model was built to assess annual costs associated with breast lumpectomy procedures with and without frozen section margin analysis to avoid reoperation. If frozen section margin analysis is used in 20% of breast lumpectomies and under a baseline assumption that 35% of initial lumpectomies without frozen section analysis result in reoperations, the potential annual cost savings are $18.2 million to payers and $0.4 million to providers. Under the same baseline assumption, if 100% of all health care facilities adopted the use of frozen section margin analysis for breast lumpectomy procedures, the potential annual cost savings are $90.9 million to payers and $1.8 million to providers. On the basis of 10,000 simulations, use of intraoperative frozen section margin analysis yields cost saving for payers and is cost neutral to slightly cost saving for providers. This economic analysis indicates that widespread use of frozen section margin evaluation intraoperatively to guide surgical resection in breast lumpectomy cases and minimize reoperations would be beneficial to cost savings not only for the patient but also for payers and, in most cases, for providers. Copyright © 2016 by American Society of Clinical Oncology.
A method for identifying EMI critical circuits during development of a large C3
NASA Astrophysics Data System (ADS)
Barr, Douglas H.
The circuit analysis methods and process Boeing Aerospace used on a large, ground-based military command, control, and communications (C3) system are described. This analysis was designed to help identify electromagnetic interference (EMI) critical circuits. The methodology used the MIL-E-6051 equipment criticality categories as the basis for defining critical circuits, relational database technology to help sort through and account for all of the approximately 5000 system signal cables, and Macintosh Plus personal computers to predict critical circuits based on safety margin analysis. The EMI circuit analysis process systematically examined all system circuits to identify which ones were likely to be EMI critical. The process used two separate, sequential safety margin analyses to identify critical circuits (conservative safety margin analysis, and detailed safety margin analysis). These analyses used field-to-wire and wire-to-wire coupling models using both worst-case and detailed circuit parameters (physical and electrical) to predict circuit safety margins. This process identified the predicted critical circuits that could then be verified by test.
Miniature star tracker for small remote sensing satellites
NASA Astrophysics Data System (ADS)
Cassidy, Lawrence W.; Schlom, Leslie
1995-01-01
Designers of future remote sensing spacecraft, including platforms for Mission to Planet Earth and small satellites, will be driven to provide spacecraft designs that maximize data return and minimize hardware and operating costs. The attitude determination subsystems of these spacecraft must likewise provide maximum capability and versatility at an affordable price. Hughes Danbury Optical Systems (HDOS) has developed the Model HD-1003 Miniature Star Tracker which combines high accuracy, high reliability and growth margin for `all-stellar' capability in a compact, radiation tolerant design that meets these future spacecraft needs and whose cost is competitive with horizon sensors and digital fine sum sensors. Begun in 1991, our HD-1003 development program has now entered the hardware qualification phase. This paper acquaints spacecraft designers with the design and performance capabilities of the HD- 1003 tracker. We highlight the tracker's unique features which include: (1) Very small size (165 cu. in.). (2) Low weight (7 lbs). (3) Multi-star tracking (6 stars simultaneously). (4) Eighteen arc-sec (3-sigma) accuracy. (5) Growth margin for `all-stellar' attitude reference.
Applied Time Domain Stability Margin Assessment for Nonlinear Time-Varying Systems
NASA Technical Reports Server (NTRS)
Kiefer, J. M.; Johnson, M. D.; Wall, J. H.; Dominguez, A.
2016-01-01
The baseline stability margins for NASA's Space Launch System (SLS) launch vehicle were generated via the classical approach of linearizing the system equations of motion and determining the gain and phase margins from the resulting frequency domain model. To improve the fidelity of the classical methods, the linear frequency domain approach can be extended by replacing static, memoryless nonlinearities with describing functions. This technique, however, does not address the time varying nature of the dynamics of a launch vehicle in flight. An alternative technique for the evaluation of the stability of the nonlinear launch vehicle dynamics along its trajectory is to incrementally adjust the gain and/or time delay in the time domain simulation until the system exhibits unstable behavior. This technique has the added benefit of providing a direct comparison between the time domain and frequency domain tools in support of simulation validation. This technique was implemented by using the Stability Aerospace Vehicle Analysis Tool (SAVANT) computer simulation to evaluate the stability of the SLS system with the Adaptive Augmenting Control (AAC) active and inactive along its ascent trajectory. The gains for which the vehicle maintains apparent time-domain stability defines the gain margins, and the time delay similarly defines the phase margin. This method of extracting the control stability margins from the time-domain simulation is relatively straightforward and the resultant margins can be compared to the linearized system results. The sections herein describe the techniques employed to extract the time-domain margins, compare the results between these nonlinear and the linear methods, and provide explanations for observed discrepancies. The SLS ascent trajectory was simulated with SAVANT and the classical linear stability margins were evaluated at one second intervals. The linear analysis was performed with the AAC algorithm disabled to attain baseline stability margins. At each time point, the system was linearized about the current operating point using Simulink's built-in solver. Each linearized system in time was evaluated for its rigid-body gain margin (high frequency gain margin), rigid-body phase margin, and aero gain margin (low frequency gain margin) for each control axis. Using the stability margins derived from the baseline linearization approach, the time domain derived stability margins were determined by executing time domain simulations in which axis-specific incremental gain and phase adjustments were made to the nominal system about the expected neutral stability point at specific flight times. The baseline stability margin time histories were used to shift the system gain to various values around the zero margin point such that a precise amount of expected gain margin was maintained throughout flight. When assessing the gain margins, the gain was applied starting at the time point under consideration, thereafter following the variation in the margin found in the linear analysis. When assessing the rigid-body phase margin, a constant time delay was applied to the system starting at the time point under consideration. If the baseline stability margins were correctly determined via the linear analysis, the time domain simulation results should contain unstable behavior at certain gain and phase values. Examples will be shown from repeated simulations with variable added gain and phase lag. Faithfulness of margins calculated from the linear analysis to the nonlinear system will be demonstrated.
A Variance Distribution Model of Surface EMG Signals Based on Inverse Gamma Distribution.
Hayashi, Hideaki; Furui, Akira; Kurita, Yuichi; Tsuji, Toshio
2017-11-01
Objective: This paper describes the formulation of a surface electromyogram (EMG) model capable of representing the variance distribution of EMG signals. Methods: In the model, EMG signals are handled based on a Gaussian white noise process with a mean of zero for each variance value. EMG signal variance is taken as a random variable that follows inverse gamma distribution, allowing the representation of noise superimposed onto this variance. Variance distribution estimation based on marginal likelihood maximization is also outlined in this paper. The procedure can be approximated using rectified and smoothed EMG signals, thereby allowing the determination of distribution parameters in real time at low computational cost. Results: A simulation experiment was performed to evaluate the accuracy of distribution estimation using artificially generated EMG signals, with results demonstrating that the proposed model's accuracy is higher than that of maximum-likelihood-based estimation. Analysis of variance distribution using real EMG data also suggested a relationship between variance distribution and signal-dependent noise. Conclusion: The study reported here was conducted to examine the performance of a proposed surface EMG model capable of representing variance distribution and a related distribution parameter estimation method. Experiments using artificial and real EMG data demonstrated the validity of the model. Significance: Variance distribution estimated using the proposed model exhibits potential in the estimation of muscle force. Objective: This paper describes the formulation of a surface electromyogram (EMG) model capable of representing the variance distribution of EMG signals. Methods: In the model, EMG signals are handled based on a Gaussian white noise process with a mean of zero for each variance value. EMG signal variance is taken as a random variable that follows inverse gamma distribution, allowing the representation of noise superimposed onto this variance. Variance distribution estimation based on marginal likelihood maximization is also outlined in this paper. The procedure can be approximated using rectified and smoothed EMG signals, thereby allowing the determination of distribution parameters in real time at low computational cost. Results: A simulation experiment was performed to evaluate the accuracy of distribution estimation using artificially generated EMG signals, with results demonstrating that the proposed model's accuracy is higher than that of maximum-likelihood-based estimation. Analysis of variance distribution using real EMG data also suggested a relationship between variance distribution and signal-dependent noise. Conclusion: The study reported here was conducted to examine the performance of a proposed surface EMG model capable of representing variance distribution and a related distribution parameter estimation method. Experiments using artificial and real EMG data demonstrated the validity of the model. Significance: Variance distribution estimated using the proposed model exhibits potential in the estimation of muscle force.
The development of accurate and high quality radiotherapy treatment delivery
NASA Astrophysics Data System (ADS)
Griffiths, Susan E.
Accurate radiotherapy delivery is required for curing cancer. Historical radiotherapy accuracy studies at Leeds (1983-1991) are discussed in context of when radiographers were not involved in practice design. The seminal research was unique in being led by a radiographer practitioner, and in prospectively studying the accuracy of different techniques within one department. The viability of alignment of treatment beams with marks painted on a patient's skin varied daily, and, using film I showed that the alignment of treatment on anatomy varied. I then led 6 sequential studies with collaborating oncologists. Unique outcomes were in identifying the origins of treatment inaccuracies, implementing and evidencing changes in multi-disciplinary practice, thus improving accuracy and reproducibility generally and achieving accuracy for the pelvis to within current norms. Innovations included: discontinuation of painted skin marks and developing whole-body patient positioning using lasers, tattoos, and standardised supports; unification of set-up conditions through planning and treatment; planning normal tissue margins round target tissue to allow for inaccuracies (1985); improved manual shielding methods, changed equipment usage, its quality assurance and design; influenced the development of portal imaging and image analysis. Consequences and current implications. The research, still cited internationally, contributed to clinical management of lymphoma, and critically underpins contemporary practice. It led to my becoming the first radiographer invited into multi-disciplinary collaborative work, to advise in the first multi-centre clinical trials to consider treatment delivery accuracy, contribute to books written from within other disciplines and inform guidelines for good practice so helping to improve practices, with recent publications. I thus led my profession into research activity. Later work included development of a national staffing formula for radiotherapy Centres, and contributing to the evidence-base for improved National radiotherapy resourcing. I recently researched and developed a textbook (second edition) on quality in treatment delivery.
van Bogaert, Louis-Jacques
2015-04-01
To describe the accuracy of the diagnosis of involved excision margins after loop electrosurgical excision procedure (LEEP) in a low-resource setting. Cross-sectional study of 176 LEEPs indicated for a cytological report of high-grade squamous intraepithelial lesion (HGSIL). A total of 72 HIV-positive and 104 HIV-negative women with cervical intraepithelial neoplasia (CIN) ≥ 2 on their LEEP histology report with involved excision margins were enrolled in the study. All patients underwent either a repeat LEEP or a hysterectomy. The specimens were evaluated for residual/recurrent CIN ≥ 2 or less. Persistent/recurrent CIN ≥ 2 was diagnosed in 139 (79.4%) instances and microinvasive squamous cell carcinoma in 6 (3.4%). Thirty (17.2%) showed CIN1. The persistence/recurrence rate was 72.2% and 88.5% in HIV-positive and HIV-negative women, respectively (χ2 = 7.5, p = 0.006). In > 80% the diagnosis of involved excision margins was confirmed, a positive predictive value of 82.4%. In the absence of more accurate follow-up methods such as HPV testing or co-testing with cytology, a correct diagnosis of margin status, especially when involved, is an important guide to further management and follow-up.
Aboushelib, Moustafa Nabil; Elmahy, Waleed AbdelMeguid; Ghazy, Mohammed Hamed
2012-08-01
The aim of this study was to evaluate the internal adaptation and marginal properties of ceramic laminate veneers fabricated using pressable and machinable CAD/CAM techniques. 40 ceramic laminate veneers were fabricated by either milling ceramic blocks using a CAD/CAM system (group 1 n=20) or press-on veneering using lost wax technique (group 2 n=20). The veneers were acid etched using hydrofluoric acid, silanated, and cemented on their corresponding prepared teeth. All specimens were stored under water (37 °C) for 60 days, then received thermocycling (15,000 cycles between 5 and 55 °C and dwell time of 90 s) followed by cyclic loading (100,000 cycles between 50 and 100 N) before immersion in basic fuchsine dye for 24 h. Half of the specimens in each group were sectioned in labio-lingual direction and the rest were horizontally sectioned using precision cutting machine (n=10). Dye penetration, internal cement film thickness, and vertical and horizontal marginal gaps at the incisal and cervical regions were measured (α=0.05). Pressable ceramic veneers demonstrated significantly lower (F=8.916, P<0.005) vertical and horizontal marginal gaps at the cervical and incisal margins and lower cement film thickness (F=50.921, P<0.001) compared to machinable ceramic veneers. The inferior marginal properties of machinable ceramic veneers were associated with significantly higher microleakage values. Pressable ceramic laminate veneers produced higher marginal adaptation, homogenous and thinner cement film thickness, and improved resistance to microleakage compared to machinable ceramic veneers. The manufacturing process influences internal and marginal fit of ceramic veneers. Therefore, dentist and laboratory technicians should choose a manufacturing process with careful consideration. Copyright © 2012 Elsevier Ltd. All rights reserved.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Bakhtiari, M; Schmitt, J; Sarfaraz, M
2015-06-15
Purpose: To establish a minimum number of patients required to obtain statistically accurate Planning Target Volume (PTV) margins for prostate Intensity Modulated Radiation Therapy (IMRT). Methods: A total of 320 prostate patients, consisting of a total number of 9311 daily setups, were analyzed. These patients had gone under IMRT treatments. Daily localization was done using the skin marks and the proper shifts were determined by the CBCT to match the prostate gland. The Van Herk formalism is used to obtain the margins using the systematic and random setup variations. The total patient population was divided into different grouping sizes varyingmore » from 1 group of 320 patients to 64 groups of 5 patients. Each grouping was used to determine the average PTV margin and its associated standard deviation. Results: Analyzing all 320 patients lead to an average Superior-Inferior margin of 1.15 cm. The grouping with 10 patients per group (32 groups) resulted to an average PTV margin between 0.6–1.7 cm with the mean value of 1.09 cm and a standard deviation (STD) of 0.30 cm. As the number of patients in groups increases the mean value of average margin between groups tends to converge to the true average PTV of 1.15 cm and STD decreases. For groups of 20, 64, and 160 patients a Superior-Inferior margin of 1.12, 1.14, and 1.16 cm with STD of 0.22, 0.11, and 0.01 cm were found, respectively. Similar tendency was observed for Left-Right and Anterior-Posterior margins. Conclusion: The estimation of the required margin for PTV strongly depends on the number of patients studied. According to this study at least ∼60 patients are needed to calculate a statistically acceptable PTV margin for a criterion of STD < 0.1 cm. Numbers greater than ∼60 patients do little to increase the accuracy of the PTV margin estimation.« less
Fridman, Eran; Na'ara, Shorook; Agarwal, Jaiprakash; Amit, Moran; Bachar, Gideon; Villaret, Andrea Bolzoni; Brandao, Jose; Cernea, Claudio R; Chaturvedi, Pankaj; Clark, Jonathan; Ebrahimi, Ardalan; Fliss, Dan M; Jonnalagadda, Sashikanth; Kohler, Hugo F; Kowalski, Luiz P; Kreppel, Matthias; Liao, Chun-Ta; Patel, Snehal G; Patel, Raj P; Robbins, K Thomas; Shah, Jatin P; Shpitzer, Thomas; Yen, Tzu-Chen; Zöller, Joachim E; Gil, Ziv
2018-05-14
Up to half of patients with oral cavity squamous cell carcinoma (OCSCC) have stage I to II disease. When adequate resection is attained, no further treatment is needed; however, re-resection or radiotherapy may be indicated for patients with positive or close margins. This multicenter study evaluated the outcomes and role of adjuvant treatment in patients with stage I to II OCSCC. Overall survival (OS), disease-specific survival, local-free survival, and disease-free survival rates were calculated with Kaplan-Meier analysis. Of 1257 patients with T1-2N0M0 disease, 33 (2.6%) had positive margins, and 205 (16.3%) had close margins. The 5-year OS rate was 80% for patients with clear margins, 52% for patients with close margins, and 63% for patients with positive margins (P < .0001). In a multivariate analysis, age, depth of invasion, and margins were independent predictors of outcome. Close margins were associated with a >2-fold increase in the risk of recurrence (P < .0001). The multivariate analysis revealed that adjuvant treatment significantly improved the outcomes of patients with close/positive margins (P = .002 to .03). Patients with stage I to II OCSCC and positive/close margins have poor long-term outcomes. For this population, adjuvant treatment may be associated with improved survival. Cancer 2018. © 2018 American Cancer Society. © 2018 American Cancer Society.
Petralia, Giuseppe; Musi, Gennaro; Padhani, Anwar R; Summers, Paul; Renne, Giuseppe; Alessi, Sarah; Raimondi, Sara; Matei, Deliu V; Renne, Salvatore L; Jereczek-Fossa, Barbara A; De Cobelli, Ottavio; Bellomi, Massimo
2015-02-01
To investigate whether use of multiparametric magnetic resonance (MR) imaging-directed intraoperative frozen-section (IFS) analysis during nerve-sparing robot-assisted radical prostatectomy reduces the rate of positive surgical margins. This retrospective analysis of prospectively acquired data was approved by an institutional ethics committee, and the requirement for informed consent was waived. Data were reviewed for 134 patients who underwent preoperative multiparametric MR imaging (T2 weighted, diffusion weighted, and dynamic contrast-material enhanced) and nerve-sparing robot-assisted radical prostatectomy, during which IFS analysis was used, and secondary resections were performed when IFS results were positive for cancer. Control patients (n = 134) matched for age, prostate-specific antigen level, and stage were selected from a pool of 322 patients who underwent nerve-sparing robot-assisted radical prostatectomy without multiparametric MR imaging and IFS analysis. Rates of positive surgical margins were compared by means of the McNemar test, and a multivariate conditional logistic regression model was used to estimate the odds ratio of positive surgical margins for patients who underwent MR imaging and IFS analysis compared with control subjects. Eighteen patients who underwent MR imaging and IFS analysis underwent secondary resections, and 13 of these patients were found to have negative surgical margins at final pathologic examination. Positive surgical margins were found less frequently in the patients who underwent MR imaging and IFS analysis than in control patients (7.5% vs 18.7%, P = .01). When the differences in risk factors are taken into account, patients who underwent MR imaging and IFS had one-seventh the risk of having positive surgical margins relative to control patients (adjusted odds ratio: 0.15; 95% confidence interval: 0.04, 0.61). The significantly lower rate of positive surgical margins compared with that in control patients provides preliminary evidence of the positive clinical effect of multiparametric MR imaging-directed IFS analysis for patients who undergo prostatectomy. © RSNA, 2014.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Kim, Jinkoo, E-mail: jkim3@hfhs.or; Hammoud, Rabih; Pradhan, Deepak
2010-07-15
Purpose: To evaluate different similarity metrics (SM) using natural calcifications and observation-based measures to determine the most accurate prostate and seminal vesicle localization on daily cone-beam CT (CBCT) images. Methods and Materials: CBCT images of 29 patients were retrospectively analyzed; 14 patients with prostate calcifications (calcification data set) and 15 patients without calcifications (no-calcification data set). Three groups of test registrations were performed. Test 1: 70 CT/CBCT pairs from calcification dataset were registered using 17 SMs (6,580 registrations) and compared using the calcification mismatch error as an endpoint. Test 2: Using the four best SMs from Test 1, 75 CT/CBCTmore » pairs in the no-calcification data set were registered (300 registrations). Accuracy of contour overlays was ranked visually. Test 3: For the best SM from Tests 1 and 2, accuracy was estimated using 356 CT/CBCT registrations. Additionally, target expansion margins were investigated for generating registration regions of interest. Results: Test 1-Incremental sign correlation (ISC), gradient correlation (GC), gradient difference (GD), and normalized cross correlation (NCC) showed the smallest errors ({mu} {+-} {sigma}: 1.6 {+-} 0.9 {approx} 2.9 {+-} 2.1 mm). Test 2-Two of the three reviewers ranked GC higher. Test 3-Using GC, 96% of registrations showed <3-mm error when calcifications were filtered. Errors were left/right: 0.1 {+-} 0.5mm, anterior/posterior: 0.8 {+-} 1.0mm, and superior/inferior: 0.5 {+-} 1.1 mm. The existence of calcifications increased the success rate to 97%. Expansion margins of 4-10 mm were equally successful. Conclusion: Gradient-based SMs were most accurate. Estimated error was found to be <3 mm (1.1 mm SD) in 96% of the registrations. Results suggest that the contour expansion margin should be no less than 4 mm.« less
The use of CT derived solid modelling of the pelvis in planning cancer resections.
Bruns, J; Habermann, C R; Rüther, W; Delling, D
2010-06-01
Resection of malignant tumors of the pelvis is demanding. To avoid disabling hemipelvectomies, years ago internal hemipelvectomy combined with partial pelvic replacements had become a surgical procedure. To achieve adequate reconstructions custom-made replacements were recommended. In early stages of the surgical procedure using megaprostheses, individual pelvic models were manufactured. Since little is known about the accuracy of such models we analysed the charts of 24 patients (25 models) for whom an individual model of the osseous pelvis had been manufactured. Two patients refused surgery. In 23 patients partial resection of the bony pelvis was performed followed by a partial pelvic replacement (13x), hip transposition procedure (5x), ilio-sacral resection (4x), or revision surgery. In all patients who received a partial pelvic replacement, the fit of the replacement was optimal. No major unplanned resection was necessary. The same was observed in patients who received a hip transposition procedure or an ilio-sacral resection. Oncologically, in most of the patients we achieved wide resection margins (14x). In 5 patients the margins were marginal (4x) or intralesional (1x). In two cases the aim was a palliative resection because of a metastatic disease (1x) or benign entity (1x). Pelvic models are helpful tools to planning the manufacture of partial pelvic replacements and ensuring optimal osseous resection of the involved bone. Further attempts have to be made to evaluate the aim of navigational techniques regarding the accuracy of the osseous and soft-tissue resection.
H. Pylori as a predictor of marginal ulceration: A nationwide analysis.
Schulman, Allison R; Abougergi, Marwan S; Thompson, Christopher C
2017-03-01
Helicobacter pylori has been implicated as a risk factor for development of marginal ulceration following gastric bypass, although studies have been small and yielded conflicting results. This study sought to determine the relationship between H. pylori infection and development of marginal ulceration following bariatric surgery in a nationwide analysis. This was a retrospective cohort study using the 2012 Nationwide Inpatient Sample (NIS) database. Discharges with ICD-9-CM code indicating marginal ulceration and a secondary ICD-9-CM code for bariatric surgery were included. Primary outcome was incidence of marginal ulceration. A stepwise forward selection model was used to build the multivariate logistic regression model based on known risk factors. A P value of 0.05 was considered significant. There were 253,765 patients who met inclusion criteria. Prevalence of marginal ulceration was 3.90%. Of those patients found to have marginal ulceration, 31.20% of patients were H. pylori-positive. Final multivariate regression analysis revealed that H. pylori was the strongest independent predictor of marginal ulceration. H. pylori is an independent predictor of marginal ulceration using a large national database. Preoperative testing for and eradication of H. pylori prior to bariatric surgery may be an important preventive measure to reduce the incidence of ulcer development. © 2017 The Obesity Society.
Lazo Gonzalez, Eduardo; Hilgenfeld, Tim; Kickingereder, Philipp; Bendszus, Martin; Heiland, Sabine; Ozga, Ann-Kathrin; Sommer, Andreas; Lux, Christopher J.; Zingler, Sebastian
2017-01-01
Objective The objective of this prospective study was to evaluate whether magnetic resonance imaging (MRI) is equivalent to lateral cephalometric radiographs (LCR, “gold standard”) in cephalometric analysis. Methods The applied MRI technique was optimized for short scanning time, high resolution, high contrast and geometric accuracy. Prior to orthodontic treatment, 20 patients (mean age ± SD, 13.95 years ± 5.34) received MRI and LCR. MRI datasets were postprocessed into lateral cephalograms. Cephalometric analysis was performed twice by two independent observers for both modalities with an interval of 4 weeks. Eight bilateral and 10 midsagittal landmarks were identified, and 24 widely used measurements (14 angles, 10 distances) were calculated. Statistical analysis was performed by using intraclass correlation coefficient (ICC), Bland-Altman analysis and two one-sided tests (TOST) within the predefined equivalence margin of ± 2°/mm. Results Geometric accuracy of the MRI technique was confirmed by phantom measurements. Mean intraobserver ICC were 0.977/0.975 for MRI and 0.975/0.961 for LCR. Average interobserver ICC were 0.980 for MRI and 0.929 for LCR. Bland-Altman analysis showed high levels of agreement between the two modalities, bias range (mean ± SD) was -0.66 to 0.61 mm (0.06 ± 0.44) for distances and -1.33 to 1.14° (0.06 ± 0.71) for angles. Except for the interincisal angle (p = 0.17) all measurements were statistically equivalent (p < 0.05). Conclusions This study demonstrates feasibility of orthodontic treatment planning without radiation exposure based on MRI. High-resolution isotropic MRI datasets can be transformed into lateral cephalograms allowing reliable measurements as applied in orthodontic routine with high concordance to the corresponding measurements on LCR. PMID:28334054
Heil, Alexander; Lazo Gonzalez, Eduardo; Hilgenfeld, Tim; Kickingereder, Philipp; Bendszus, Martin; Heiland, Sabine; Ozga, Ann-Kathrin; Sommer, Andreas; Lux, Christopher J; Zingler, Sebastian
2017-01-01
The objective of this prospective study was to evaluate whether magnetic resonance imaging (MRI) is equivalent to lateral cephalometric radiographs (LCR, "gold standard") in cephalometric analysis. The applied MRI technique was optimized for short scanning time, high resolution, high contrast and geometric accuracy. Prior to orthodontic treatment, 20 patients (mean age ± SD, 13.95 years ± 5.34) received MRI and LCR. MRI datasets were postprocessed into lateral cephalograms. Cephalometric analysis was performed twice by two independent observers for both modalities with an interval of 4 weeks. Eight bilateral and 10 midsagittal landmarks were identified, and 24 widely used measurements (14 angles, 10 distances) were calculated. Statistical analysis was performed by using intraclass correlation coefficient (ICC), Bland-Altman analysis and two one-sided tests (TOST) within the predefined equivalence margin of ± 2°/mm. Geometric accuracy of the MRI technique was confirmed by phantom measurements. Mean intraobserver ICC were 0.977/0.975 for MRI and 0.975/0.961 for LCR. Average interobserver ICC were 0.980 for MRI and 0.929 for LCR. Bland-Altman analysis showed high levels of agreement between the two modalities, bias range (mean ± SD) was -0.66 to 0.61 mm (0.06 ± 0.44) for distances and -1.33 to 1.14° (0.06 ± 0.71) for angles. Except for the interincisal angle (p = 0.17) all measurements were statistically equivalent (p < 0.05). This study demonstrates feasibility of orthodontic treatment planning without radiation exposure based on MRI. High-resolution isotropic MRI datasets can be transformed into lateral cephalograms allowing reliable measurements as applied in orthodontic routine with high concordance to the corresponding measurements on LCR.
Baksi, B Güniz
2008-07-01
The aim of this study was to compare the subjective diagnostic quality of F-speed film images and original and enhanced storage phosphor plate (SPP) digital images for the visualization of periodontal ligament space (PLS) and periapical (PB) and alveolar crestal bone (CB) and to assess the accuracy of these image modalities for the measurement of alveolar bone levels. Standardized images of six dried mandibles were obtained with film and Digora SPPs. Six evaluators rated the visibility of anatomical structures using a three-point scale. Alveolar bone levels were measured from the coronal-most tip of the marginal bone to a reference point. Results were compared by using Friedman and Wilcoxon signed-ranks tests. The kappa (kappa) statistic was used to measure agreement among observers. The measurements were compared using repeated measures analysis of variance and Bonferroni tests (P = 0.05). A paired t test was used for comparison with true bone levels (P = 0.05). Enhanced SPP images were rated superior, followed by film and then the original SPP images, for the evaluation of anatomical structures. The value of kappa rose from fair to substantial after the enhancement of the SPP images. Film and enhanced SPP images provided alveolar bone lengths close to the true bone lengths. Enhancement of digital images provided better visibility and resulted in comparable accuracy to film images for the evaluation of periodontal structures.
Novel maximum-margin training algorithms for supervised neural networks.
Ludwig, Oswaldo; Nunes, Urbano
2010-06-01
This paper proposes three novel training methods, two of them based on the backpropagation approach and a third one based on information theory for multilayer perceptron (MLP) binary classifiers. Both backpropagation methods are based on the maximal-margin (MM) principle. The first one, based on the gradient descent with adaptive learning rate algorithm (GDX) and named maximum-margin GDX (MMGDX), directly increases the margin of the MLP output-layer hyperplane. The proposed method jointly optimizes both MLP layers in a single process, backpropagating the gradient of an MM-based objective function, through the output and hidden layers, in order to create a hidden-layer space that enables a higher margin for the output-layer hyperplane, avoiding the testing of many arbitrary kernels, as occurs in case of support vector machine (SVM) training. The proposed MM-based objective function aims to stretch out the margin to its limit. An objective function based on Lp-norm is also proposed in order to take into account the idea of support vectors, however, overcoming the complexity involved in solving a constrained optimization problem, usually in SVM training. In fact, all the training methods proposed in this paper have time and space complexities O(N) while usual SVM training methods have time complexity O(N (3)) and space complexity O(N (2)) , where N is the training-data-set size. The second approach, named minimization of interclass interference (MICI), has an objective function inspired on the Fisher discriminant analysis. Such algorithm aims to create an MLP hidden output where the patterns have a desirable statistical distribution. In both training methods, the maximum area under ROC curve (AUC) is applied as stop criterion. The third approach offers a robust training framework able to take the best of each proposed training method. The main idea is to compose a neural model by using neurons extracted from three other neural networks, each one previously trained by MICI, MMGDX, and Levenberg-Marquard (LM), respectively. The resulting neural network was named assembled neural network (ASNN). Benchmark data sets of real-world problems have been used in experiments that enable a comparison with other state-of-the-art classifiers. The results provide evidence of the effectiveness of our methods regarding accuracy, AUC, and balanced error rate.
Redesigned Gas Mass Flow Sensors for Space Shuttle Pressure Control System and Fuel Cell System
NASA Technical Reports Server (NTRS)
1996-01-01
A program was conducted to determine if a state of the art micro-machined silicon solid state flow sensor could be used to replace the existing space shuttle orbiter flow sensors. The rather aggressive goal was to obtain a new sensor which would also be a multi-gas sensor and operate over a much wider flow range and with a higher degree of accuracy than the existing sensors. Two types of sensors were tested. The first type was a venturi throat design and the second was a bypass design. The accuracy of venturi design was found to be marginally acceptable. The bypass sensor was much better although it still did not fully reach the accuracy goal. Two main problems were identified which would require further work.
NASA Astrophysics Data System (ADS)
Bar, Anna; Snavely, Nicholas; Chen, Nathaniel; Jacques, Steven; Gareau, Daniel S.
2012-03-01
Screening cancer in excision margins may be done with confocal microscopy to save time and cost over the gold standard histopathology (H&E). However, diagnostic accuracy requires sufficient contrast. Reflectance mode enables detection of large (>500um) nodular tumors. Enhanced nuclear contrast with acridine orange fluorescence mode additionally enables detection of tiny (<50um) basal cell carcinomas. Here, we present a novel combination of three modes to detect squamous cell carcinoma (SCC). Accurate screening of SCC requires eosin fluorescence, reflectance and acridine orange fluorescence to enable contrast for cytoplasm, collagen and nuclei respectively. Combining these signals replicates H&E for rapid clinical translation.
Optical Coherence Tomography and Its Role in Mohs Micrographic Surgery: A Case Report
Chan, C. Stanley; Rohrer, Thomas E.
2012-01-01
Optical coherence tomography (OCT) is an imaging technology with the potential to provide high-resolution images of the skin non-invasively. With this device, it is possible to identify a host of skin structures including tumors. In this case report, we demonstrate the use of an OCT device in delineating a lateral tumor margin of an ill-defined basal cell carcinoma prior to Mohs micrographic surgery. Following surgery, the OCT images are compared to histologic sections to confirm their accuracy. OCT technology has the potential to be a vital tool for dermatologists and particularly Mohs surgeons in identifying tumor margins and potentially reducing the number of invasive procedures needed. PMID:23341806
Alex, Deepa; Shetty, Y. Bharath; Miranda, Glynis Anita; Prabhu, M. Bharath; Karkera, Reshma
2015-01-01
Background: Conventional investing and casting techniques are time-consuming and usually requires 2–4 h for completion. Accelerated nonstandard, casting techniques have been reported to achieve similar quality results in significantly less time, namely, in 30–40 min. During casting, it is essential to achieve compensation for the shrinkage of solidifying alloy by investment expansion. The metal casting ring restricts the thermal expansion of investment because the thermal expansion of the ring is lesser than that of the investment. The use of casting ring was challenged with the introduction of the ringless technique. Materials and Methods: A total of 40 test samples of nickel chromium (Ni-Cr) cast copings were obtained from the patterns fabricated using inlay casting wax. The 20 wax patterns were invested using metal ring and 20 wax patterns were invested using the ringless investment system. Of both the groups, 10 samples underwent conventional casting, and the other 10 underwent accelerated casting. The patterns were casted using the induction casting technique. All the test samples of cast copings were evaluated for vertical marginal gaps at four points on the die employing a stereo optical microscope. Results: The vertical marginal discrepancy data obtained were tabulated. Mean and standard deviations were obtained. Vertical discrepancies were analyzed using analysis of variance and Tukey honestly significantly different. The data obtained were found to be very highly significant (P < 0.001). Mean vertical gap was the maximum for Group II (53.64 μm) followed by Group IV (47.62 μm), Group I (44.83 μm) and Group III (35.35 μm). Conclusion: The Ni-Cr cast copings fabricated with the conventional casting using ringless investment system showed significantly better marginal fit than that of cast copings fabricated from conventional and accelerated casting with metal ring investment and accelerated casting using ringless investment since those copings had shown the least vertical marginal discrepancies among the four methods evaluated in this study. PMID:26929488
Reddy, Nagam Raja; Reddy, Jakranpally Sathya; Padmaja, Bramha Josyula Indira; Reddy, Budigi Madan Mohan; Sunil, Motupalli; Reddy, Bommireddy Tejeswar
2016-01-01
Aims: To evaluate the accuracy of dies made from dual arch impressions using different sectional dual arch trays, combinations of elastomeric impression materials, and the sequence of pour of dies. Subjects and Methods: The dual arch impression materials were grouped into three groups depending on the combination of impression materials used and each group is subdivided into four subgroups. A sample size of 8 in each subgroup yielding a total 96 impressions will be made into three groups of 32 each (Group I, II, and III). Group I constitute impressions made using monophase (M) impression material, Group II constitute impressions made using combination of heavy body and light body (HL), and Group III constitute impressions made using combination of putty and light body (PL). Dies obtained were evaluated with a travelling microscope to measure the buccolingual width of the tooth at the margin by using the sharp corners of the notches as reference points. Statistical Analysis Used: Descriptive analysis namely mean and standard deviation, one-way analysis of variance test. Results: The results obtained in this study indicate that though not statistically significant, the metal dual arch trays performed better when compared to the plastic trays in reproducing die dimensions. Conclusions: From the results obtained, dies poured from combination of heavy body and light body impressions using plastic or metal dual arch trays showed least variation in bucco-lingual dimension from master model. PMID:27141172
GRACE Mass Flux Measurements of Inland and Marginal Seas from Mascons: Analysis and Validation
NASA Astrophysics Data System (ADS)
Loomis, B.; Luthcke, S. B.; Sabaka, T. J.
2015-12-01
The latest GRACE time-variable gravity mascon solution from the NASA Goddard Space Flight Center (GSFC) applies an optimized set of models and constraints towards the direct measurement of 1-arc-degree global mass flux parameters each month. Separate mascon spatial constraint regions have been defined for the largest inland and marginal seas: Mediterranean Sea, Black Sea, Caspian Sea, Red Sea, and Hudson Bay. The mascon estimation approach, when applied with well-designed constraints, minimizes signal leakage across regional boundaries and eliminates the need for post-processing strategies. These post-processing techniques (e.g. smoothed averaging kernels) are necessary for computing regional mass change from the unconstrained spherical harmonics provided by the GRACE project to reduce the effect of noisy high degree and order terms, but introduce signal leakage into and out of the considered region. These mass signals are also difficult to obtain from altimetry measurements due to the comparatively sparse temperature and salinity data in these regions, which is needed to compute and remove the steric component of sea level variations. We provide new GSFC mascon measurements of these inland and marginal seas and compare to results obtained from kernel-averaged spherical harmonic solutions and steric-corrected altimetry measurements. The relative accuracy of the various solutions is determined by incorporating their output into the set of forward models applied in our processing of the GRACE Level-1B data and analyzing the effect on the inter-satellite range-rate residuals, where a reduction in residuals is a direct validation of improved solution quality.
Comparison of prosthetic models produced by traditional and additive manufacturing methods.
Park, Jin-Young; Kim, Hae-Young; Kim, Ji-Hwan; Kim, Jae-Hong; Kim, Woong-Chul
2015-08-01
The purpose of this study was to verify the clinical-feasibility of additive manufacturing by comparing the accuracy of four different manufacturing methods for metal coping: the conventional lost wax technique (CLWT); subtractive methods with wax blank milling (WBM); and two additive methods, multi jet modeling (MJM), and micro-stereolithography (Micro-SLA). Thirty study models were created using an acrylic model with the maxillary upper right canine, first premolar, and first molar teeth. Based on the scan files from a non-contact blue light scanner (Identica; Medit Co. Ltd., Seoul, Korea), thirty cores were produced using the WBM, MJM, and Micro-SLA methods, respectively, and another thirty frameworks were produced using the CLWT method. To measure the marginal and internal gap, the silicone replica method was adopted, and the silicone images obtained were evaluated using a digital microscope (KH-7700; Hirox, Tokyo, Japan) at 140X magnification. Analyses were performed using two-way analysis of variance (ANOVA) and Tukey post hoc test (α=.05). The mean marginal gaps and internal gaps showed significant differences according to tooth type (P<.001 and P<.001, respectively) and manufacturing method (P<.037 and P<.001, respectively). Micro-SLA did not show any significant difference from CLWT regarding mean marginal gap compared to the WBM and MJM methods. The mean values of gaps resulting from the four different manufacturing methods were within a clinically allowable range, and, thus, the clinical use of additive manufacturing methods is acceptable as an alternative to the traditional lost wax-technique and subtractive manufacturing.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Qi, X; Yang, Y; Jack, N
Purpose: On-board MRI provides superior soft-tissue contrast, allowing patient alignment using tumor or nearby critical structures. This study aims to study H&N MRI-guided IGRT to analyze inter-fraction patient setup variations using soft-tissue targets and design appropriate CTV-to-PTV margin and clinical implication. Methods: 282 MR images for 10 H&N IMRT patients treated on a ViewRay system were retrospectively analyzed. Patients were immobilized using a thermoplastic mask on a customized headrest fitted in a radiofrequency coil and positioned to soft-tissue targets. The inter-fraction patient displacements were recorded to compute the PTV margins using the recipe: 2.5∑+0.7σ. New IMRT plans optimized on themore » revised PTVs were generated to evaluate the delivered dose distributions. An in-house dose deformation registration tool was used to assess the resulting dosimetric consequences when margin adaption is performed based on weekly MR images. The cumulative doses were compared to the reduced margin plans for targets and critical structures. Results: The inter-fraction displacements (and standard deviations), ∑ and σ were tabulated for MRI and compared to kVCBCT. The computed CTV-to-PTV margin was 3.5mm for soft-tissue based registration. There were minimal differences between the planned and delivered doses when comparing clinical and the PTV reduced margin plans: the paired t-tests yielded p=0.38 and 0.66 between the planned and delivered doses for the adapted margin plans for the maximum cord and mean parotid dose, respectively. Target V95 received comparable doses as planned for the reduced margin plans. Conclusion: The 0.35T MRI offers acceptable soft-tissue contrast and good spatial resolution for patient alignment and target visualization. Better tumor conspicuity from MRI allows soft-tissue based alignments with potentially improved accuracy, suggesting a benefit of margin reduction for H&N radiotherapy. The reduced margin plans (i.e., 2 mm) resulted in improved normal structure sparing and accurate dose delivery to achieve intended treatment goal under MR guidance.« less
Hamady, Zaed Z R; Lodge, J Peter A; Welsh, Fenella K; Toogood, Giles J; White, Alan; John, Timothy; Rees, Myrddin
2014-03-01
To investigate the influence of clear surgical resection margin width on disease recurrence rate after intentionally curative resection of colorectal liver metastases. There is consensus that a histological positive resection margin is a predictor of disease recurrence after resection of colorectal liver metastases. The dispute, however, over the width of cancer-free resection margin required is ongoing. Analysis of observational prospectively collected data for 2715 patients who underwent primary resection of colorectal liver metastases from 2 major hepatobiliary units in the United Kingdom. Histological cancer-free resection margin was classified as positive (if cancer cells present at less than 1 mm from the resection margin) or negative (if the distance between the cancer and the margin is 1 mm or more). The negative margin was further classified according to the distance from the tumor in millimeters. Predictors of disease-free survival were analyzed in univariate and multivariate analyses. A case-match analysis by a propensity score method was undertaken to reduce bias. A 1-mm cancer-free resection margin was sufficient to achieve 33% 5-year overall disease-free survival. Extra margin width did not add disease-free survival advantage (P > 0.05). After the propensity case-match analysis, there is no statistical difference in disease-free survival between patients with negative narrow and wider margin clearance [hazard ratio (HR) 1.0; 95% (confidence interval) CI: 0.9-1.2; P = 0.579 at 5-mm cutoff and HR 1.1; 95% CI: 0.96-1.3; P = 0.149 at 10-mm cutoff]. Patients with extrahepatic disease and positive lymph node primary tumor did not have disease-free survival advantage despite surgical margin clearance (9 months for <1-mm vs 12 months for ≥1-mm margin clearance; P = 0.062). One-mm cancer-free resection margin achieved in patients with colorectal liver metastases should now be considered the standard of care.
Forecast models for suicide: Time-series analysis with data from Italy.
Preti, Antonio; Lentini, Gianluca
2016-01-01
The prediction of suicidal behavior is a complex task. To fine-tune targeted preventative interventions, predictive analytics (i.e. forecasting future risk of suicide) is more important than exploratory data analysis (pattern recognition, e.g. detection of seasonality in suicide time series). This study sets out to investigate the accuracy of forecasting models of suicide for men and women. A total of 101 499 male suicides and of 39 681 female suicides - occurred in Italy from 1969 to 2003 - were investigated. In order to apply the forecasting model and test its accuracy, the time series were split into a training set (1969 to 1996; 336 months) and a test set (1997 to 2003; 84 months). The main outcome was the accuracy of forecasting models on the monthly number of suicides. These measures of accuracy were used: mean absolute error; root mean squared error; mean absolute percentage error; mean absolute scaled error. In both male and female suicides a change in the trend pattern was observed, with an increase from 1969 onwards to reach a maximum around 1990 and decrease thereafter. The variances attributable to the seasonal and trend components were, respectively, 24% and 64% in male suicides, and 28% and 41% in female ones. Both annual and seasonal historical trends of monthly data contributed to forecast future trends of suicide with a margin of error around 10%. The finding is clearer in male than in female time series of suicide. The main conclusion of the study is that models taking seasonality into account seem to be able to derive information on deviation from the mean when this occurs as a zenith, but they fail to reproduce it when it occurs as a nadir. Preventative efforts should concentrate on the factors that influence the occurrence of increases above the main trend in both seasonal and cyclic patterns of suicides.
Cross-validation to select Bayesian hierarchical models in phylogenetics.
Duchêne, Sebastián; Duchêne, David A; Di Giallonardo, Francesca; Eden, John-Sebastian; Geoghegan, Jemma L; Holt, Kathryn E; Ho, Simon Y W; Holmes, Edward C
2016-05-26
Recent developments in Bayesian phylogenetic models have increased the range of inferences that can be drawn from molecular sequence data. Accordingly, model selection has become an important component of phylogenetic analysis. Methods of model selection generally consider the likelihood of the data under the model in question. In the context of Bayesian phylogenetics, the most common approach involves estimating the marginal likelihood, which is typically done by integrating the likelihood across model parameters, weighted by the prior. Although this method is accurate, it is sensitive to the presence of improper priors. We explored an alternative approach based on cross-validation that is widely used in evolutionary analysis. This involves comparing models according to their predictive performance. We analysed simulated data and a range of viral and bacterial data sets using a cross-validation approach to compare a variety of molecular clock and demographic models. Our results show that cross-validation can be effective in distinguishing between strict- and relaxed-clock models and in identifying demographic models that allow growth in population size over time. In most of our empirical data analyses, the model selected using cross-validation was able to match that selected using marginal-likelihood estimation. The accuracy of cross-validation appears to improve with longer sequence data, particularly when distinguishing between relaxed-clock models. Cross-validation is a useful method for Bayesian phylogenetic model selection. This method can be readily implemented even when considering complex models where selecting an appropriate prior for all parameters may be difficult.
On a fast calculation of structure factors at a subatomic resolution.
Afonine, P V; Urzhumtsev, A
2004-01-01
In the last decade, the progress of protein crystallography allowed several protein structures to be solved at a resolution higher than 0.9 A. Such studies provide researchers with important new information reflecting very fine structural details. The signal from these details is very weak with respect to that corresponding to the whole structure. Its analysis requires high-quality data, which previously were available only for crystals of small molecules, and a high accuracy of calculations. The calculation of structure factors using direct formulae, traditional for 'small-molecule' crystallography, allows a relatively simple accuracy control. For macromolecular crystals, diffraction data sets at a subatomic resolution contain hundreds of thousands of reflections, and the number of parameters used to describe the corresponding models may reach the same order. Therefore, the direct way of calculating structure factors becomes very time expensive when applied to large molecules. These problems of high accuracy and computational efficiency require a re-examination of computer tools and algorithms. The calculation of model structure factors through an intermediate generation of an electron density [Sayre (1951). Acta Cryst. 4, 362-367; Ten Eyck (1977). Acta Cryst. A33, 486-492] may be much more computationally efficient, but contains some parameters (grid step, 'effective' atom radii etc.) whose influence on the accuracy of the calculation is not straightforward. At the same time, the choice of parameters within safety margins that largely ensure a sufficient accuracy may result in a significant loss of the CPU time, making it close to the time for the direct-formulae calculations. The impact of the different parameters on the computer efficiency of structure-factor calculation is studied. It is shown that an appropriate choice of these parameters allows the structure factors to be obtained with a high accuracy and in a significantly shorter time than that required when using the direct formulae. Practical algorithms for the optimal choice of the parameters are suggested.
Lithosphere structure and subsidence evolution of the conjugate S-African and Argentine margins
NASA Astrophysics Data System (ADS)
Dressel, Ingo; Scheck-Wenderoth, Magdalena; Cacace, Mauro; Götze, Hans-Jürgen; Franke, Dieter
2016-04-01
The bathymetric evolution of the South Atlantic passive continental margins is a matter of debate. Though it is commonly accepted that passive margins experience thermal subsidence as a result of lithospheric cooling as well as load induced subsidence in response to sediment deposition it is disputed if the South Atlantic passive margins were affected by additional processes affecting the subsidence history after continental breakup. We present a subsidence analysis along the SW African margin and offshore Argentina and restore paleobathymetries to assess the subsidence evolution of the margin. These results are discussed with respect to mechanisms behind margin evolution. Therefore, we use available information about the lithosphere-scale present-day structural configuration of these margins as a starting point for the subsidence analysis. A multi 1D backward modelling method is applied to separate individual subsidence components such as the thermal- as well as the load induced subsidence and to restore paleobathymetries for the conjugate margins. The comparison of the restored paleobathymetries shows that the conjugate margins evolve differently: Continuous subsidence is obtained offshore Argentina whereas the subsidence history of the SW African margin is interrupted by phases of uplift. This differing results for both margins correlate also with different structural configurations of the subcrustal mantle. In the light of these results we discuss possible implications for uplift mechanisms.
Oehler, Christoph; Lang, Stephanie; Dimmerling, Peter; Bolesch, Christian; Kloeck, Stephan; Tini, Alessandra; Glanzmann, Christoph; Najafi, Yousef; Studer, Gabriela; Zwahlen, Daniel R
2014-11-11
To evaluate PTV margins for hypofractionated IGRT of prostate comparing kV/kV imaging or CBCT. Between 2009 and 2012, 20 patients with low- (LR), intermediate- (IR) and high-risk (HR) prostate cancer were treated with VMAT in supine position with fiducial markers (FM), endorectal balloon (ERB) and full bladder. CBCT's and kV/kV imaging were performed before and additional CBCT's after treatment assessing intra-fraction motion. CTVP for 5 patients with LR and CTVPSV for 5 patients with IR/HR prostate cancer were contoured independently by 3 radiation oncologists using MRI. The van Hark formula (PTV margin =2.5Σ +0.7σ) was applied to calculate PTV margins of prostate/seminal vesicles (P/PSV) using CBCT or FM. 172 and 52 CBCTs before and after RT and 507 kV/kV images before RT were analysed. Differences between FM in CBCT or in planar kV image pairs were below 1 mm. Accounting for both random and systematic uncertainties anisotropic PTV margins were 5-8 mm for P (LR) and 6-11 mm for PSV (IR/HR). Random uncertainties like intra-fraction and inter-fraction (setup) uncertainties were of similar magnitude (0.9-1.4 mm). Largest uncertainty was introduced by CTV delineation (LR: 1-2 mm, IR/HR: 1.6-3.5 mm). Patient positioning using bone matching or ERB-matching resulted in larger PTV margins. For IGRT CBCT or kV/kV-image pairs with FM are interchangeable in respect of accuracy. Especially for hypofractionated RT, PTV margins can be kept in the range of 5 mm or below if stringent daily IGRT, ideally including prostate tracking, is applied. MR-based CTV delineation optimization is recommended.
Smith, Toby O; Drew, Benjamin T; Toms, Andoni P
2012-07-01
Magnetic resonance imaging (MRI) and magnetic resonance arthrography (MRA) have gained increasing favour in the assessment of patients with suspected glenoid labral injuries. The purpose of this study was to determine the diagnostic accuracy of MRI or MRA in the detection of gleniod labral lesions. A systematic review was undertaken of the electronic databases Cochrane Central Register of Controlled Trials, MEDLINE, EMBASE, AMED and CINAHL, in addition to a search of unpublished literature databases. All studies which compared the ability of MRI or MRA (index test) to assess gleniod labral tears or lesions, when verified with a surgical procedure (arthroscopy or open surgery-reference test) were included. Data extraction and methodological appraisal using the QUADAS tool were both conducted by two reviewers independently. Data were analysed through a summary receiver operator characteristic curve and pooled sensitivity and specificity analysis were calculated with 95% confidence intervals. Sixty studies including 4,667 shoulders from 4,574 patients were reviewed. There appeared slightly greater diagnostic test accuracy for MRA over MRI for the detection of overall gleniod labral lesions (MRA-sensitivity 88%, specificity 93% vs. MRI sensitivity 76% vs. specificity 87%). Methodologically, studies recruited and identified their samples appropriately and clearly defined the radiological procedures. In general, it was not clearly defined why patients were lost during the study, and studies were poor at recording whether the same clinical data were available to the radiologist interpreting the MRI or MRA as would be available in clinical practice. Most studies did not state whether the surgeon interpreting the arthroscopic procedure was blinded to the results of the MR or MRA imaging. Based on the available literature, overall MRA appeared marginally superior to MRI for the detection of glenohumeral labral lesions. Level 2a.
Oebisu, Naoto; Hoshi, Manabu; Ieguchi, Makoto; Takada, Jun; Iwai, Tadashi; Ohsawa, Masahiko; Nakamura, Hiroaki
2014-10-01
Resolution of ultrasonography (US) has undergone marked development. Additionally, a new-generation contrast medium (Sonazoid) used for US is newly available. Contrast-enhanced US has been widely used for evaluating several types of cancer. In the present study, we evaluated the ability of color Doppler US (CDUS) and Sonazoid to differentiate between benign and malignant soft tissue tumors. A total of 180 patients (87 male, 93 female) were enrolled in the present study. The patient ages ranged from 1 to 91 years (mean 58.1±20.0 years). The maximum size, depth, tumor margins, shape, echogenicity and textural pattern were measured on gray-scale images. CDUS was used to evaluate the intratumoral blood flow with and without Sonazoid. Peak systolic flow velocity (Vp), mean flow velocity (Vm), resistivity index (RI) and pulsatility index (PI) of each detected intratumoral artery were automatically calculated with power Doppler US (PDUS). The present study included 118 benign and 62 malignant tumors. Statistical significances were found in size, depth, tumor margin and textural pattern but not in shape or echogenicity on gray-scale images. Before Sonazoid injection, CDUS findings showed 55% sensitivity, 77% specificity and 69% accuracy, whereas contrast-enhanced CDUS showed 87% sensitivity, 68% specificity and 74% accuracy. There were no statistically significant differences between malignant and benign tumors regarding the mean Vp, Vm, RI and PI values determined on PDUS. In conclusion, contrast-enhanced CDUS proved to be a reliable diagnostic tool for detecting malignant potential in soft tissue tumors.
High-sensitivity aeromagnetic survey of the US Atlantic continental margin.
Behrendt, John C.; Klitgord, Kim D.
1980-01-01
The US Geological Survey contracted a high-sensitivity, digital aeromagnetic survey that was flown over the US Atlantic continental margin over a period of 15 months between 1974 and 1976. The 185 000 km of profile data have a relative accuracy approaching a few tenths of a nanotesla, which allowed compilation into maps at a scale of 1:250 000, with a contour interval of 2 nT. Automatic data processing using the Werner method allowed calculations of apparent depth to sources of the magnetic anomalies on all of the profiles, assuming a dike or interface as a source. Comparison of the computed depths to magnetic basement with multichannel seismic profiles across the survey area helped to reduce ambiguities in magnetic depth estimates and enabled interpolation of basement structures between seismic profiles. The resulting map showing depth to basement of the Atlantic continental margin is compatible with available multichannel seismic data, and we consider it a reasonable representation of the base of the sedimentary column. -Authors
An integrated skin marking tool for use with optical coherence tomography (OCT)
NASA Astrophysics Data System (ADS)
Patalay, Rakesh; Craythorne, Emma; Mallipeddi, Raj; Coleman, Andrew
2017-02-01
Optical coherence tomography (OCT) has been shown to provide clinically valuable images that can aid in the assessment of the pre-surgical margin in basal cell carcinoma (BCC). The accuracy and speed with which these images can be used to help delineate margins in the clinic are currently constrained by the need to suspend imaging whilst a pen is used to mark the skin. This constraint has been circumvented here by the design of a trigger-activated ink-loaded nib integrated with the OCT probe. The adapted OCT probe enables a mark to be placed on the skin precisely where a region of interest can be seen in the OCT images, accurately and reproducibly. The adapted probe is described and a comparison of its performance and early experience of its clinical use are reported here. Initial results indicate that the integrated skin marking probe makes margin delineation under OCT image-guidance faster, more accurate and more clinically acceptable.
Schönberger, Joana; Erdelt, Kurt-Jürgen; Bäumer, Daniel; Beuer, Florian
2017-11-01
The purpose of this in vitro study was to compare the precision of fit of frameworks milled from semi-sintered regular zirconia and high-translucent (HT) zirconia blanks, fabricated with two different CAD/CAM systems. Three-unit, posterior fixed dental prostheses (FDP) frameworks were fabricated for standardized dies (n = 11) with two different laboratory computer-aided design (CAD)/computer-aided manufacturing (CAM) systems (Cercon/Ceramill). The replica technique was used to evaluate the marginal and internal fit under an optical microscope. Evaluation of the data was performed according to prior studies at a level of significance of 5%. The systems showed a statistically significant influence on the internal fit of the frameworks (p ≤ 0.001) and on the marginal fit (p < 0.001). The type of material showed no influence on the marginal fit for the Cercon system (p = 0.636) and on the marginal fit (p = 0.064) and the internal fit (p = 0.316) for the Ceramill system, while regular zirconia from Cercon showed higher internal values than HT zirconia (p = 0.016). Both investigated systems showed clinically acceptable values within the limitations of this in vitro study. However, one showed less internal accuracy when regular zirconia was used.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Garcia-Garduno, O. A.; Larraga-Gutierrez, J. M.; Celis, M. A.
2006-09-08
An acrylic phantom was designed and constructed to assess the geometrical accuracy of CT, MRI and PET images for stereotactic radiotherapy (SRT) and radiosurgery (SRS) applications. The phantom was suited for each image modality with a specific tracer and compared with CT images to measure the radial deviation between the reference marks in the phantom. It was found that for MRI the maximum mean deviation is 1.9 {+-} 0.2 mm compared to 2.4 {+-} 0.3 mm reported for PET. These results will be used for margin outlining in SRS and SRT treatment planning.
NASA Astrophysics Data System (ADS)
Amanullah Tomal, A. N. M.; Saleh, Tanveer; Raisuddin Khan, Md.
2017-11-01
At present, two important processes, namely CNC machining and rapid prototyping (RP) are being used to create prototypes and functional products. Combining both additive and subtractive processes into a single platform would be advantageous. However, there are two important aspects need to be taken into consideration for this process hybridization. First is the integration of two different control systems for two processes and secondly maximizing workpiece alignment accuracy during the changeover step. Recently we have developed a new hybrid system which incorporates Fused Deposition Modelling (FDM) as RP Process and CNC grinding operation as subtractive manufacturing process into a single setup. Several objects were produced with different layer thickness for example 0.1 mm, 0.15 mm and 0.2 mm. It was observed that pure FDM method is unable to attain desired dimensional accuracy and can be improved by a considerable margin about 66% to 80%, if finishing operation by grinding is carried out. It was also observed layer thickness plays a role on the dimensional accuracy and best accuracy is achieved with the minimum layer thickness (0.1 mm).
Needle-based polarization-sensitive OCT of breast tumor (Conference Presentation)
NASA Astrophysics Data System (ADS)
Villiger, Martin; Lorenser, Dirk; McLaughlin, Robert A.; Quirk, Bryden C.; Kirk, Rodney W.; Bouma, Brett E.; Sampson, David D.
2016-03-01
OCT imaging through miniature needle probes has extended the range of OCT and enabled structural imaging deep inside breast tissue, with the potential to assist in the intraoperative assessment of tumor margins. However, in many situations, scattering contrast alone is insufficient to clearly identify and delineate malignant areas. Here, we present a portable, depth-encoded polarization-sensitive OCT system, connected to a miniature needle probe. From the measured polarization states we constructed the tissue Mueller matrix at each sample location and improved the accuracy of the measured polarization states through incoherent averaging before retrieving the depth-resolved tissue birefringence. With the Mueller matrix at hand, additional polarization properties such as depolarization are readily available. We then imaged freshly excised breast tissue from a patient undergoing lumpectomy. The reconstructed local retardation highlighted regions of connective tissue, which exhibited birefringence due to the abundance of collagen fibers, and offered excellent contrast to areas of malignant tissue, which exhibited less birefringence due to their different tissue composition. Results were validated against co-located histology sections. The combination of needle-based imaging with the complementary contrast provided by polarization-sensitive analysis offers a powerful instrument for advanced tissue imaging and has potential to aid in the assessment of tumor margins during the resection of breast cancer.
Dumont, F; Tilly, C; Dartigues, P; Goéré, D; Honoré, C; Elias, D
2015-09-01
Low rectal cancers carry a high risk of circumferential margin involvement (CRM+). The anatomy of the lower part of the rectum and a long course of chemoradiotherapy (CRT) limit the accuracy of imaging to predict the CRM+. Additional criteria are required. Eighty six patients undergoing rectal resection with a sphincter-sparing procedure after CRT for low rectal cancer between 2000 and 2013 were retrospectively reviewed. Risk factors of CRM+ and the cut-off number of risk factors required to accurately predict the CRM+ were analyzed. The CRM+ rate was 9.3% and in the multivariate analysis, the significant risk factors were a tumor size exceeding 3 cm, poor response to CRT and a fixed tumor. The best cut-off to predict CRM+ was the presence of 2 risk factors. Patients with 0-1 and 2-3 risk factors had a CRM+ respectively in 1.3% and 50% of cases and a 3-year recurrence rate of 7% and 35% after a median follow-up of 50 months. Poor response, a residual tumor greater than 3 cm and a fixed tumor are predictive of CRM+. Sphincter sparing is an oncological safety procedure for patients with 0-1 criteria but not for patients with 2-3 criteria. Copyright © 2015 Elsevier Ltd. All rights reserved.
Kim, Young-sun; Trillaud, Hervé; Rhim, Hyunchul; Lim, Hyo K; Mali, Willem; Voogt, Marianne; Barkhausen, Jörg; Eckey, Thomas; Köhler, Max O; Keserci, Bilgin; Mougenot, Charles; Sokka, Shunmugavelu D; Soini, Jouko; Nieminen, Heikki J
2012-11-01
To evaluate the accuracy of the size and location of the ablation zone produced by volumetric magnetic resonance (MR) imaging-guided high-intensity focused ultrasound ablation of uterine fibroids on the basis of MR thermometric analysis and to assess the effects of a feedback control technique. This prospective study was approved by the institutional review board, and written informed consent was obtained. Thirty-three women with 38 uterine fibroids were treated with an MR imaging-guided high-intensity focused ultrasound system capable of volumetric feedback ablation. Size (diameter times length) and location (three-dimensional displacements) of each ablation zone induced by 527 sonications (with [n=471] and without [n=56] feedback) were analyzed according to the thermal dose obtained with MR thermometry. Prospectively defined acceptance ranges of targeting accuracy were ±5 mm in left-right (LR) and craniocaudal (CC) directions and ±12 mm in anteroposterior (AP) direction. Effects of feedback control in 8- and 12-mm treatment cells were evaluated by using a mixed model with repeated observations within patients. Overall mean sizes of ablation zones produced by 4-, 8-, 12-, and 16-mm treatment cells (with and without feedback) were 4.6 mm±1.4 (standard deviation)×4.4 mm±4.8 (n=13), 8.9 mm±1.9×20.2 mm±6.5 (n=248), 13.0 mm±1.2×29.1 mm±5.6 (n=234), and 18.1 mm±1.4×38.2 mm±7.6 (n=32), respectively. Targeting accuracy values (displacements in absolute values) were 0.9 mm±0.7, 1.2 mm±0.9, and 2.8 mm±2.2 in LR, CC, and AP directions, respectively. Of 527 sonications, 99.8% (526 of 527) were within acceptance ranges. Feedback control had no statistically significant effect on targeting accuracy or ablation zone size. However, variations in ablation zone size were smaller in the feedback control group. Sonication accuracy of volumetric MR imaging-guided high-intensity focused ultrasound ablation of uterine fibroids appears clinically acceptable and may be further improved by feedback control to produce more consistent ablation zones. © RSNA, 2012
An Evaluation of a Markov Chain Monte Carlo Method for the Two-Parameter Logistic Model.
ERIC Educational Resources Information Center
Kim, Seock-Ho; Cohen, Allan S.
The accuracy of the Markov Chain Monte Carlo (MCMC) procedure Gibbs sampling was considered for estimation of item parameters of the two-parameter logistic model. Data for the Law School Admission Test (LSAT) Section 6 were analyzed to illustrate the MCMC procedure. In addition, simulated data sets were analyzed using the MCMC, marginal Bayesian…
Deng, Yingyuan; Wang, Tianfu; Chen, Siping; Liu, Weixiang
2017-01-01
The aim of the study is to screen the significant sonographic features by logistic regression analysis and fit a model to diagnose thyroid nodules. A total of 525 pathological thyroid nodules were retrospectively analyzed. All the nodules underwent conventional ultrasonography (US), strain elastosonography (SE), and contrast -enhanced ultrasound (CEUS). Those nodules’ 12 suspicious sonographic features were used to assess thyroid nodules. The significant features of diagnosing thyroid nodules were picked out by logistic regression analysis. All variables that were statistically related to diagnosis of thyroid nodules, at a level of p < 0.05 were embodied in a logistic regression analysis model. The significant features in the logistic regression model of diagnosing thyroid nodules were calcification, suspected cervical lymph node metastasis, hypoenhancement pattern, margin, shape, vascularity, posterior acoustic, echogenicity, and elastography score. According to the results of logistic regression analysis, the formula that could predict whether or not thyroid nodules are malignant was established. The area under the receiver operating curve (ROC) was 0.930 and the sensitivity, specificity, accuracy, positive predictive value, and negative predictive value were 83.77%, 89.56%, 87.05%, 86.04%, and 87.79% respectively. PMID:29228030
Pang, Tiantian; Huang, Leidan; Deng, Yingyuan; Wang, Tianfu; Chen, Siping; Gong, Xuehao; Liu, Weixiang
2017-01-01
The aim of the study is to screen the significant sonographic features by logistic regression analysis and fit a model to diagnose thyroid nodules. A total of 525 pathological thyroid nodules were retrospectively analyzed. All the nodules underwent conventional ultrasonography (US), strain elastosonography (SE), and contrast -enhanced ultrasound (CEUS). Those nodules' 12 suspicious sonographic features were used to assess thyroid nodules. The significant features of diagnosing thyroid nodules were picked out by logistic regression analysis. All variables that were statistically related to diagnosis of thyroid nodules, at a level of p < 0.05 were embodied in a logistic regression analysis model. The significant features in the logistic regression model of diagnosing thyroid nodules were calcification, suspected cervical lymph node metastasis, hypoenhancement pattern, margin, shape, vascularity, posterior acoustic, echogenicity, and elastography score. According to the results of logistic regression analysis, the formula that could predict whether or not thyroid nodules are malignant was established. The area under the receiver operating curve (ROC) was 0.930 and the sensitivity, specificity, accuracy, positive predictive value, and negative predictive value were 83.77%, 89.56%, 87.05%, 86.04%, and 87.79% respectively.
Heintze, Siegward D
2007-01-01
An accepted principle in restorative dentistry states that restorations should be placed with the best marginal quality possible to avoid postoperative sensitivity, marginal discoloration, and secondary caries. Different laboratory methods claim to predict the clinical performance of restorative materials, for example, tests of bond strength and microleakage and gap analysis. The purpose of this review was twofold: (1) find studies that correlated the results of bond strength tests with either microleakage or gap analysis for the same materials, and (2) find studies that correlated the results of microleakage and/or gaps with the clinical parameters for the same materials. Furthermore, influencing factors on the results of the laboratory tests were reviewed and assessed. For the first question, searches for studies were conducted in the MEDLINE database and IADR/AADR abtracts online with specific search and inclusion criteria. The outcome for each study was assessed on the basis of the statistical test applied in the study, and finally the number of studies with or without correlation was compiled. For the second question, results of the quantitative marginal analysis of Class V restorations published by the University of Zürich with the same test protocol and prospective clinical trials were searched that investigated the same materials for at least 2 years in Class V cavities. Pearson correlation coefficients were calculated for pooled data of materials and clinical outcome parameters such as retention loss, marginal discoloration, marginal integrity, and secondary caries. For the correlation of dye penetration and clinical outcome, studies on Class V restorations published by the same research institute were searched in MEDLINE that examined the same adhesive systems as the selected clinical trials. For the correlation bond strength/microleakage, 30 studies were included into the review, and for the correlation bond strength/gap analysis 18 studies. For both topics, about 80% of the studies revealed that there was no correlation between the two methods. For the correlation quantitative marginal analysis/clinical outcome, data were compared to the clinical outcome of 11 selected clinical studies. In only 2 out of the 11 studies (18%) did the clinical outcome match the prognosis based on the laboratory tests; the remaining studies did not show any correlation. When pooling data on 20 adhesive systems, no correlation was found between the percentage of continuous margin of restorations placed in extracted premolars and the percentage of teeth that showed no retention loss in clinical studies, no discoloured margins, acceptable margins, or absence of secondary caries. With regard to the correlation of dye penetration and clinical studies, no sufficient number of studies was found that matched the inclusion criteria. However, literature data suggest that there is no correlation between microleakage data as measured in the laboratory and clinical parameters. The results of bond strength tests did not correlate with laboratory tests that evaluated the marginal seal of restorations such as microleakage or gap analysis. The quantitative marginal analysis of Class V fillings in the laboratory was unable to predict the performance of the same materials in vivo. Therefore, microleakage tests or the quantitative marginal analysis should be abandoned and research should focus on laboratory tests that are validated with regard to their ability to satisfactorily predict the clinical performance of restorative materials.
Desmonts, A; Tillou, X; Le Gal, S; Secco, M; Orczyk, C; Bensadoun, H; Doerfler, A
2013-10-01
To evaluate the feasibility and the efficiency of intraoperative ex vivo ultrasound of resection margins in patients undergoing partial nephrectomy by urologist. Patients undergoing partial nephrectomy from July 2010 to November 2012 for T1-T2 renal tumors were included in analysis. Tumor margin status was immediately determined by ex vivo ultrasound done by the surgeon himself. Results were compared with margin status on definitive pathological evaluation. A total of 26 men and 15 women with a median age of 61 (30-82) years old were included in analysis. Intraoperative ex vivo ultrasound revealed negative surgical margins in 38 cases and positive margins in two. Final pathological results revealed negative margins in all except one case. Ultrasound sensitivity and specificity were 100% and 97%, respectively. Mean ultrasound duration was 1minute±1. Mean tumor and margin sizes were 3.4±1.8cm and 2.38±1.76mm, respectively. Intraoperative ex vivo ultrasound of resection margins in patients undergoing partial nephrectomy by a urologist seemed to be feasible, efficient and easy. Copyright © 2013 Elsevier Masson SAS. All rights reserved.
Clinical and semiquantitative marginal analysis of four tooth-coloured inlay systems at 3 years.
Gladys, S; Van Meerbeek, B; Inokoshi, S; Willems, G; Braem, M; Lambrechts, P; Vanherle, G
1995-12-01
The marginal quality of four tooth-coloured inlay systems was clinically investigated and subjected to computer-aided semiquantitative marginal analysis under scanning electron microscopy (SEM) after 3 years of clinical service. Three of the restoration types were made using the Cerec CAD-CAM apparatus: one was milled from preformed glass ceramic blocks, and the two other inlay types were milled from preformed porcelain blocks. The fourth system was based on an experimental indirect resin composite inlay system. Each inlay type was luted with a different luting resin composite. The clinical evaluation was performed with a mirror and explorer by two clinicians separately, and the marginal analysis was conducted microscopically on replicas (SEM x 200). After 3 years in situ, all the restorations were clinically acceptable. No recurrent caries was observed. Marginal analysis under SEM detected a high percentage of submargination for all four systems, which suggests that their respective resin composite luting agents were all subject to wear. The percentage of marginal fractures on the enamel side as well as on the inlay side did not increase dramatically compared to the 6-month results. The first recall after 6 months of clinical service indicated how tooth-coloured inlays behave at their margins. The 3-year results confirmed the early findings, indicating that wear of resin composite lutes is important and present in all systems. The two ceramic materials showed a similar behaviour at the margins. The resin composite inlay performed better at the inlay site than at the enamel site.
Fulford, Janice M.; Clayton, Christopher S.
2015-10-09
The calibration device and proposed method were used to calibrate a sample of in-service USGS steel and electric groundwater tapes. The sample of in-service groundwater steel tapes were in relatively good condition. All steel tapes, except one, were accurate to ±0.01 ft per 100 ft over their entire length. One steel tape, which had obvious damage in the first hundred feet, was marginally outside the accuracy of ±0.01 ft per 100 ft by 0.001 ft. The sample of in-service groundwater-level electric tapes were in a range of conditions—from like new, with cosmetic damage, to nonfunctional. The in-service electric tapes did not meet the USGS accuracy recommendation of ±0.01 ft. In-service electric tapes, except for the nonfunctional tape, were accurate to about ±0.03 ft per 100 ft. A comparison of new with in-service electric tapes found that steel-core electric tapes maintained their length and accuracy better than electric tapes without a steel core. The in-service steel tapes could be used as is and achieve USGS accuracy recommendations for groundwater-level measurements. The in-service electric tapes require tape corrections to achieve USGS accuracy recommendations for groundwater-level measurement.
Nejatidanesh, Farahnaz; Shakibamehr, Amir Hossein; Savabi, Omid
2016-02-01
To evaluate the accuracy of marginal and internal adaptation of 2 computer-aided design/computer-aided manufacturing (CAD/CAM) and 2 conventionally made cement retained implant-supported restorations. An abutment and its corresponding fixture analog (Astra Tech) were inserted in left central incisor area of a maxillary cast. Four types of implant-supported single restorations were fabricated on the abutment (n = 10): e.max CAD (Cerec AC system), zirconia-based (Cercon system), IPS e.max Press, and metal-ceramic restorations. The internal and marginal gaps of the studied groups were measured by replica method and stereomicroscope. Data were subjected to 1-way ANOVA and Scheffe post hoc tests (α = 0.05). Mean internal gaps of Cercon (59.48 ± 16.49 μm) and e.max Press (75.62 ± 26.92 μm) groups were significantly different from e.max CAD (120.29 ± 16.74 μm) group, but there was no significant difference between metal-ceramic restorations (89.65 ± 47.84 μm) and e.max CAD. The marginal gaps of e.max CAD (32.02 ± 10.38 μm) and Cercon restorations (34.26 ± 11.41 μm) were significantly superior from metal ceramics (59.19 ± 17.81 μm) and e.max press (74.99 ± 24.51 μm). Within the limitations of this study, it can be concluded that although the marginal and internal gaps of the studied implant-supported restorations were in the clinically acceptable range, single crowns made with CAD/CAM technology provide better marginal fit.
Baele, Guy; Lemey, Philippe; Vansteelandt, Stijn
2013-03-06
Accurate model comparison requires extensive computation times, especially for parameter-rich models of sequence evolution. In the Bayesian framework, model selection is typically performed through the evaluation of a Bayes factor, the ratio of two marginal likelihoods (one for each model). Recently introduced techniques to estimate (log) marginal likelihoods, such as path sampling and stepping-stone sampling, offer increased accuracy over the traditional harmonic mean estimator at an increased computational cost. Most often, each model's marginal likelihood will be estimated individually, which leads the resulting Bayes factor to suffer from errors associated with each of these independent estimation processes. We here assess the original 'model-switch' path sampling approach for direct Bayes factor estimation in phylogenetics, as well as an extension that uses more samples, to construct a direct path between two competing models, thereby eliminating the need to calculate each model's marginal likelihood independently. Further, we provide a competing Bayes factor estimator using an adaptation of the recently introduced stepping-stone sampling algorithm and set out to determine appropriate settings for accurately calculating such Bayes factors, with context-dependent evolutionary models as an example. While we show that modest efforts are required to roughly identify the increase in model fit, only drastically increased computation times ensure the accuracy needed to detect more subtle details of the evolutionary process. We show that our adaptation of stepping-stone sampling for direct Bayes factor calculation outperforms the original path sampling approach as well as an extension that exploits more samples. Our proposed approach for Bayes factor estimation also has preferable statistical properties over the use of individual marginal likelihood estimates for both models under comparison. Assuming a sigmoid function to determine the path between two competing models, we provide evidence that a single well-chosen sigmoid shape value requires less computational efforts in order to approximate the true value of the (log) Bayes factor compared to the original approach. We show that the (log) Bayes factors calculated using path sampling and stepping-stone sampling differ drastically from those estimated using either of the harmonic mean estimators, supporting earlier claims that the latter systematically overestimate the performance of high-dimensional models, which we show can lead to erroneous conclusions. Based on our results, we argue that highly accurate estimation of differences in model fit for high-dimensional models requires much more computational effort than suggested in recent studies on marginal likelihood estimation.
2013-01-01
Background Accurate model comparison requires extensive computation times, especially for parameter-rich models of sequence evolution. In the Bayesian framework, model selection is typically performed through the evaluation of a Bayes factor, the ratio of two marginal likelihoods (one for each model). Recently introduced techniques to estimate (log) marginal likelihoods, such as path sampling and stepping-stone sampling, offer increased accuracy over the traditional harmonic mean estimator at an increased computational cost. Most often, each model’s marginal likelihood will be estimated individually, which leads the resulting Bayes factor to suffer from errors associated with each of these independent estimation processes. Results We here assess the original ‘model-switch’ path sampling approach for direct Bayes factor estimation in phylogenetics, as well as an extension that uses more samples, to construct a direct path between two competing models, thereby eliminating the need to calculate each model’s marginal likelihood independently. Further, we provide a competing Bayes factor estimator using an adaptation of the recently introduced stepping-stone sampling algorithm and set out to determine appropriate settings for accurately calculating such Bayes factors, with context-dependent evolutionary models as an example. While we show that modest efforts are required to roughly identify the increase in model fit, only drastically increased computation times ensure the accuracy needed to detect more subtle details of the evolutionary process. Conclusions We show that our adaptation of stepping-stone sampling for direct Bayes factor calculation outperforms the original path sampling approach as well as an extension that exploits more samples. Our proposed approach for Bayes factor estimation also has preferable statistical properties over the use of individual marginal likelihood estimates for both models under comparison. Assuming a sigmoid function to determine the path between two competing models, we provide evidence that a single well-chosen sigmoid shape value requires less computational efforts in order to approximate the true value of the (log) Bayes factor compared to the original approach. We show that the (log) Bayes factors calculated using path sampling and stepping-stone sampling differ drastically from those estimated using either of the harmonic mean estimators, supporting earlier claims that the latter systematically overestimate the performance of high-dimensional models, which we show can lead to erroneous conclusions. Based on our results, we argue that highly accurate estimation of differences in model fit for high-dimensional models requires much more computational effort than suggested in recent studies on marginal likelihood estimation. PMID:23497171
Heng, Yin; Chunli, Guo; Bing, Shi; Yang, Li; Jingtao, Li
2016-10-01
To enhance the accuracy in diagnosis and management of submucous cleft palate via a thorough analysis of its anatomical and functional details. Two hundred seventy-six submucous cleft palate cases from 2008 to 2014 were retrospectively investigated. Subgroup analysis were performed on the basis of preoperative velopharyngeal function, palatal morphology, cleft lip concurrence, and patient motives for treatment. Among the included cases, 96 (34.78%) were presented as velopharyngeal competence (VPC), 151 (54.71%) as velopharyngeal insufficiency (VPI), and 29 (10.51%) as marginal VPI (MVPI). Eighty cases (28.99%) also demonstrated cleft lip deformity, and 196 cases (71.01%) were merely submucous cleft palate. Compared with patients with submucous cleft palate only, those with cleft lips exhibited higher rates of complete velopharyngeal closure. The pathological spectrum of submucous cleft palate varied significantly. Only 103 (37.32%) cases met all the three diagnostic criteria proposed by Calnan. Given that the velopharyngeal closure rate varies among the subgroups, the factors analyzed in this study should be considered in the personalized manage-ment of submucous cleft palate.
Chen, C Y; Chen, J; Xia, C C; Huang, Z X; Song, B
2017-01-01
The aim of this study was to investigate the value of Gd-EOB-DTPA-enhanced MRI on hepatobiliary phase (HBP) imaging and T1 mapping sequence in the differentiation of hepatocellular carcinoma (HCC). A total of 45 patients with HCC who were to undergo a resection were enrolled in this study. Gd-EOB-DTPA-enhanced magnetic resonance examination was performed prior to resection. T1 mapping was performed before and 20 min after injection of Gd-EOB-DTPA. T1 values of the lesions were measured on pre-contrast (T1p) and during HBP (T1-HBP) on T1 maps. The signal intensity, the diameter and the margin of HCC lesions on HBP images were analyzed. The reduction in T1 value (T1d) and the reduction rate (ΔT1%) of T1 mapping between pre-contrast and HBP were calculated. The Edmondson-Steiner classification of each lesion was made after surgery. The SPSS software package was used for statistical analysis and the analysis of receiver operator characteristic (ROC) curve and area under the curve (AUC) were carried out by using MedCalc software package. Mean values of T1p and T1-HBP were 1935.4±730.8 ms and 1257.1±529.1 ms, respectively. T1p accuracy (AUC = 0.685, p = 0.037) in predicting pathological grading was similar to that of T1-HBP (AUC = 0.751, p = 0.005). A T1p of 1648.2 ms or greater had a sensitivity and specificity of 85.19% and 61.11%, respectively. A T1-HBP of 1006 ms or greater had a sensitivity and specificity of 81.84% and 61.11%, respectively. The number of HCCs with a non-smooth tumor margin was 20 (44.4%), and a non-smooth tumor margin correlated moderately with the Edmondson-Steiner grade (Spearman r = 0.491, p = 0.041). There was no significant correlation between T1d, ΔT1%, HCC signal intensity on HBP image and lesion diameter with pathologic grading. T1 mapping in pre-contrast and HBP of Gd-EOB-DTPA-enhanced MRI, a non-smooth tumor margin in the HBP of Gd-EOB-DTPA-enhanced MRI, are useful in predicting the pathologic grading of HCC.
Tissue preservation with mass spectroscopic analysis: Implications for cancer diagnostics.
Hall, O Morgan; Peer, Cody J; Figg, William D
2018-05-17
Surgical intervention is a common treatment modality for localized cancer. Post-operative analysis involves evaluation of surgical margins to assess whether all malignant tissue has been resected because positive surgical margins lead to a greater likelihood of recurrence. Secondary treatments are utilized to minimize the negative effects of positive surgical margins. Recently, in Science Translational Medicine, Zhang et al describe a new mass spectroscopic technique that could potentially decrease the likelihood of positive surgical margins. Their nondestructive in vivo tissue sampling leads to a highly accurate and rapid cancer diagnosis with great precision between healthy and malignant tissue. This new tool has the potential to improve surgical margins and accelerate cancer diagnostics by analyzing biomolecular signatures of various tissues and diseases.
Frampton, Geoff K; Jones, Jeremy; Rose, Micah; Payne, Liz
2016-11-01
Pre-eclampsia (PE) prediction based on blood pressure, presence of protein in the urine, symptoms and laboratory test abnormalities can result in false-positive diagnoses. This may lead to unnecessary antenatal admissions and preterm delivery. Blood tests that measure placental growth factor (PlGF) or the ratio of soluble fms-like tyrosine kinase 1 (sFlt-1) to PlGF could aid prediction of PE if either were added to routine clinical assessment or used as a replacement for proteinuria testing. To evaluate the diagnostic accuracy and cost-effectiveness of PlGF-based tests for patients referred to secondary care with suspected PE in weeks 20-37 of pregnancy. Systematic reviews and an economic analysis. Bibliographic databases including MEDLINE, EMBASE, Web of Science and The Cochrane Library and Database of Abstracts of Reviews of Effects were searched up to July 2015 for English-language references. Conferences, websites, systematic reviews and confidential company submissions were also accessed. Systematic reviews of test accuracy and economic studies were conducted to inform an economic analysis. Test accuracy studies were required to include women with suspected PE and report quantitatively the accuracy of PlGF-based tests; their risk of bias was assessed using the Quality Assessment of Diagnostic Accuracy Studies (QUADAS) criteria. The economic studies review had broad eligibility criteria to capture any types of economic analysis; critical appraisal employed standard checklists consistent with National Institute for Health and Care Excellence criteria. Study selection, critical appraisal and data extraction in both reviews were performed by two reviewers. An independent economic analysis was conducted based on a decision tree model, using the best evidence available. The model evaluates costs (2014, GBP) from a NHS and Personal Social Services perspective. Given the short analysis time horizon, no discounting was undertaken. Four studies were included in the systematic review of test accuracy: two on Alere's Triage ® PlGF test (Alere, Inc., San Diego, CA, USA) for predicting PE requiring delivery within a specified time and two on Roche Diagnostics' Elecsys ® sFlt-1 to PlGF ratio test (Roche Diagnostics GmbH, Mannheim, Germany) for predicting PE within a specified time. Three studies were included in the systematic review of economic studies, and two confidential company economic analyses were assessed separately. Study heterogeneity precluded meta-analyses of test accuracy or cost-analysis outcomes, so narrative syntheses were conducted to inform the independent economic model. The model predicts that, when supplementing routine clinical assessment for rule-out and rule-in of PE, the two tests would be cost-saving in weeks 20-35 of gestation, and marginally cost-saving in weeks 35-37, but with minuscule impact on quality of life. Length of neonatal intensive care unit stay was the most influential parameter in sensitivity analyses. All other sensitivity analyses had negligible effects on results. No head-to-head comparisons of the tests were identified. No studies investigated accuracy of PlGF-based tests when used as a replacement for proteinuria testing. Test accuracy studies were found to be at high risk of clinical review bias. The Triage and Elecsys tests would save money if added to routine clinical assessment for PE. The magnitude of savings is uncertain, but the tests remain cost-saving under worst-case assumptions. Further research is required to clarify how the test results would be interpreted and applied in clinical practice. This study is registered as PROSPERO CRD42015017670. The National Institute for Health Research Health Technology Assessment programme.
Evaluation of margins in head and neck squamous cell carcinoma from the surgeon's perspective.
Baumeister, Philipp; Baumüller, Konstantin; Harréus, Ulrich; Reiter, Maximilian; Welz, Christian
2018-05-01
The surgeon's evaluation of resection status based on frozen section analysis during operation and pathological examination of resected specimens often differ. For this study, we recapitulated the surgeon's perspective during an operation, accordingly classified the evaluation of margins by the surgeon, and analyzed its impact on the outcome compared with the pathological results. This was a retrospective analysis. As data sources, paper-based and digital patient files, as well as the Munich Cancer Registry database were used. Three hundred ninety-six cases were included in this analysis. Only the evaluation of margins by the surgeon influenced local control, and the pathological results influenced disease-free survival (DFS). Surprisingly, margins of >5 mm of normal tissue to cancer growth led to local control and overall survival (OS) significantly worse than 1 to 5-mm resections. The evaluation of margins by the surgeon is of significant importance for local control and OS. It is largely based on frozen section analysis, which, therefore, should be used whenever possible. © 2018 Wiley Periodicals, Inc.
Quint, Jennifer K; Müllerova, Hana; DiSantostefano, Rachael L; Forbes, Harriet; Eaton, Susan; Hurst, John R; Davis, Kourtney; Smeeth, Liam
2014-01-01
Objectives The optimal method of identifying people with chronic obstructive pulmonary disease (COPD) from electronic primary care records is not known. We assessed the accuracy of different approaches using the Clinical Practice Research Datalink, a UK electronic health record database. Setting 951 participants registered with a CPRD practice in the UK between 1 January 2004 and 31 December 2012. Individuals were selected for ≥1 of 8 algorithms to identify people with COPD. General practitioners were sent a brief questionnaire and additional evidence to support a COPD diagnosis was requested. All information received was reviewed independently by two respiratory physicians whose opinion was taken as the gold standard. Primary outcome measure The primary measure of accuracy was the positive predictive value (PPV), the proportion of people identified by each algorithm for whom COPD was confirmed. Results 951 questionnaires were sent and 738 (78%) returned. After quality control, 696 (73.2%) patients were included in the final analysis. All four algorithms including a specific COPD diagnostic code performed well. Using a diagnostic code alone, the PPV was 86.5% (77.5–92.3%) while requiring a diagnosis plus spirometry plus specific medication; the PPV was slightly higher at 89.4% (80.7–94.5%) but reduced case numbers by 10%. Algorithms without specific diagnostic codes had low PPVs (range 12.2–44.4%). Conclusions Patients with COPD can be accurately identified from UK primary care records using specific diagnostic codes. Requiring spirometry or COPD medications only marginally improved accuracy. The high accuracy applies since the introduction of an incentivised disease register for COPD as part of Quality and Outcomes Framework in 2004. PMID:25056980
DOE Office of Scientific and Technical Information (OSTI.GOV)
Ku, Ja Hyeon; Kim, Myong; Jeong, Chang Wook
2014-08-01
Purpose: To evaluate the predictive accuracy and general applicability of the locoregional failure model in a different cohort of patients treated with radical cystectomy. Methods and Materials: A total of 398 patients were included in the analysis. Death and isolated distant metastasis were considered competing events, and patients without any events were censored at the time of last follow-up. The model included the 3 variables pT classification, the number of lymph nodes identified, and margin status, as follows: low risk (≤pT2), intermediate risk (≥pT3 with ≥10 nodes removed and negative margins), and high risk (≥pT3 with <10 nodes removed ormore » positive margins). Results: The bootstrap-corrected concordance index of the model 5 years after radical cystectomy was 66.2%. When the risk stratification was applied to the validation cohort, the 5-year locoregional failure estimates were 8.3%, 21.2%, and 46.3% for the low-risk, intermediate-risk, and high-risk groups, respectively. The risk of locoregional failure differed significantly between the low-risk and intermediate-risk groups (subhazard ratio [SHR], 2.63; 95% confidence interval [CI], 1.35-5.11; P<.001) and between the low-risk and high-risk groups (SHR, 4.28; 95% CI, 2.17-8.45; P<.001). Although decision curves were appropriately affected by the incidence of the competing risk, decisions about the value of the models are not likely to be affected because the model remains of value over a wide range of threshold probabilities. Conclusions: The model is not completely accurate, but it demonstrates a modest level of discrimination, adequate calibration, and meaningful net benefit gain for prediction of locoregional failure after radical cystectomy.« less
First Results from UAS Deployed Ocean Sensor Systems during the 2013 MIZOPEX Campaign
NASA Astrophysics Data System (ADS)
Palo, S. E.; Weibel, D.; Lawrence, D.; LoDolce, G.; Bradley, A. C.; Adler, J.; Maslanik, J. A.; Walker, G.
2013-12-01
The Marginal Ice Zone Observations and Processes Experiment (MIZOPEX), is an Arctic field campaign which occurred during summer 2013. The goals of the project are to understand how warming of the marginal ice zone affects sea ice melt and if this warming has been over or underestimated by satellite measurements. To achieve these goals calibrated physical measurements, both remote and in-situ, of the marginal ice zone over scales of square kilometers with a resolution of square meters is required. This will be accomplished with a suite of unmanned aerial vehicles (UAVs) equipped with both remote sensing and in-situ instruments, air deployed microbuoys, and ship deployed buoys. In this talk we will present details about the air deployed microbouys (ADMB) and self-deployed surface sondes (SDSS) developed at the University of Colorado. Both the ADMB and SDSS share a common measurement suite with the capability to measure water temperature at three distinct depths and provide position information via GPS. The ADMB is 90 grams, 1.3 inches in diameter, 4.25 inches long and is designed for deployment from the InSitu ScanEagle platform. The designed and experimentally verified operational lifetime is 10 days, however this can be extended with additional batteries.. While the ADMB are deployed from the ScanEagle, the SDSS are vectorable and can be remotely and precisely positioned. Lab performance results, calibration results and initial results from the ADMB and SDSS that were deployed during the MIZOPEX mission will be presented. These results include day-in-the-life tests, antenna pattern analysis, range tests, temperature measurement accuracy and initial scientific results from the campaign.
Applications of remote sensing, volume 1
NASA Technical Reports Server (NTRS)
Landgrebe, D. A. (Principal Investigator)
1977-01-01
The author has identified the following significant results. ECHO successfully exploits the redundancy of states characteristics of sampled imagery of ground scenes to achieve better classification accuracy, reduce the number of classifications required, and reduce the variability of classification results. The information required to produce ECHO classifications are cell size, cell homogeneity, cell-to-field annexation parameters, input data, and a class conditional marginal density statistics deck.
40 CFR 86.1912 - How do I determine whether an engine meets the vehicle-pass criteria?
Code of Federal Regulations, 2012 CFR
2012-07-01
..., depending on the pollutant, as follows: (i) NMHC: 0.17 grams per brake horsepower-hour. (ii) CO: 0.60 grams per brake horsepower-hour. (iii) NOX: 0.50 grams per brake horsepower-hour. (iv) PM: 0.10 grams per brake horsepower-hour. (v) NOX + NMHC: 0.67 grams per brake horsepower-hour. (4) Accuracy margins for...
40 CFR 86.1912 - How do I determine whether an engine meets the vehicle-pass criteria?
Code of Federal Regulations, 2013 CFR
2013-07-01
..., depending on the pollutant, as follows: (i) NMHC: 0.17 grams per brake horsepower-hour. (ii) CO: 0.60 grams per brake horsepower-hour. (iii) NOX: 0.50 grams per brake horsepower-hour. (iv) PM: 0.10 grams per brake horsepower-hour. (v) NOX + NMHC: 0.67 grams per brake horsepower-hour. (4) Accuracy margins for...
40 CFR 86.1912 - How do I determine whether an engine meets the vehicle-pass criteria?
Code of Federal Regulations, 2014 CFR
2014-07-01
..., depending on the pollutant, as follows: (i) NMHC: 0.17 grams per brake horsepower-hour. (ii) CO: 0.60 grams per brake horsepower-hour. (iii) NOX: 0.50 grams per brake horsepower-hour. (iv) PM: 0.10 grams per brake horsepower-hour. (v) NOX + NMHC: 0.67 grams per brake horsepower-hour. (4) Accuracy margins for...
Shi, Xin-Yu; Liu, Yao; Gu, Xian-Min; Hao, Sheng-Yu; Wang, Yu-Hong; Yan, Di; Jiang, Shu-Juang
2016-08-01
The serum (1 → 3)-β-D-glucan (BG) assay has been approved for diagnosing invasive fungal diseases (IFDs). However, the performance of (1 → 3)-β-D-glucan assay in bronchoalveolar lavage (BAL) fluid is various among studies. The present study aimed to assess the accuracy of (1 → 3)-β-D-glucan assay in bronchoalveolar lavage fluid for the diagnosis of invasive fungal diseases by means of meta-analysis and systematic review of relevant studies. The sensitivity, specificity, positive likelihood ratio (PLR), negative likelihood ratio (NLR), diagnostic odds ratio (OR) and a summary receiver-operating characteristic curve of BAL-BG for diagnosing invasive fungal diseases were pooled using meta-analysis. We also performed meta-regression analysis. A total of 838 patients (138 with proven or probable invasive fungal diseases), included in 6 studies, were analyzed. The pooled sensitivity, specificity, PLR, NLR and diagnostic odds ratio were 0.52 (95%CI, 0.38-0.53), 0.58 (95%CI, 0.55-0.61), 1.34 (95%CI, 1.08-1.66), 0.82 (95% CI, 0.63-1.07) and 1.71 (95%CI, 1.01-2.92) respectively. The area under the summary receiver operating characteristic curve, with 95% confidence intervals was 0.61 (95%CI, 0.67-0.55). The accuracy of (1 → 3)-β-D-glucan test in bronchoalveolar lavage fluid is marginal, so that the results should not be interpreted alone but can be used as a part of full assessment with clinical features, image findings and other laboratory results for the diagnosis of invasive fungal diseases. Copyright © 2016 Elsevier Ltd. All rights reserved.
Distinguishing between extra natural inflation and natural inflation after BICEP2
DOE Office of Scientific and Technical Information (OSTI.GOV)
Kohri, Kazunori; Lim, C.S.; Lin, Chia-Min, E-mail: kohri@post.kek.jp, E-mail: lim@lab.twcu.ac.jp, E-mail: lin@chuo-u.ac.jp
2014-08-01
In this paper, we carefully calculated the tensor-to-scalar ratio, the running spectral index, and the running of running spectrum for (extra) natural inflation in order to compare with recent BICEP2 data, PLANCK satellite data and future 21 cm data. We discovered that the prediction for running spectral index and the running of running spectrum in natural inflation is different from that in the case of extra natural inflation. Near future observation for the running spectral index can only provide marginal accuracy which may not allow us distinguishing between extra natural inflation from natural inflation clearly unless the experimental accuracy canmore » be further improved.« less
Target margins in radiotherapy of prostate cancer
Bauman, Glenn
2016-01-01
We reviewed the literature on the use of margins in radiotherapy of patients with prostate cancer, focusing on different options for image guidance (IG) and technical issues. The search in PubMed database was limited to include studies that involved external beam radiotherapy of the intact prostate. Post-prostatectomy studies, brachytherapy and particle therapy were excluded. Each article was characterized according to the IG strategy used: positioning on external marks using room lasers, bone anatomy and soft tissue match, usage of fiducial markers, electromagnetic tracking and adapted delivery. A lack of uniformity in margin selection among institutions was evident from the review. In general, introduction of pre- and in-treatment IG was associated with smaller planning target volume (PTV) margins, but there was a lack of definitive experimental/clinical studies providing robust information on selection of exact PTV values. In addition, there is a lack of comparative research regarding the cost–benefit ratio of the different strategies: insertion of fiducial markers or electromagnetic transponders facilitates prostate gland localization but at a price of invasive procedure; frequent pre-treatment imaging increases patient in-room time, dose and labour; online plan adaptation should improve radiation delivery accuracy but requires fast and precise computation. Finally, optimal protocols for quality assurance procedures need to be established. PMID:27377353
Stability analysis of fuzzy parametric uncertain systems.
Bhiwani, R J; Patre, B M
2011-10-01
In this paper, the determination of stability margin, gain and phase margin aspects of fuzzy parametric uncertain systems are dealt. The stability analysis of uncertain linear systems with coefficients described by fuzzy functions is studied. A complexity reduced technique for determining the stability margin for FPUS is proposed. The method suggested is dependent on the order of the characteristic polynomial. In order to find the stability margin of interval polynomials of order less than 5, it is not always necessary to determine and check all four Kharitonov's polynomials. It has been shown that, for determining stability margin of FPUS of order five, four, and three we require only 3, 2, and 1 Kharitonov's polynomials respectively. Only for sixth and higher order polynomials, a complete set of Kharitonov's polynomials are needed to determine the stability margin. Thus for lower order systems, the calculations are reduced to a large extent. This idea has been extended to determine the stability margin of fuzzy interval polynomials. It is also shown that the gain and phase margin of FPUS can be determined analytically without using graphical techniques. Copyright © 2011 ISA. Published by Elsevier Ltd. All rights reserved.
Research on cardiovascular disease prediction based on distance metric learning
NASA Astrophysics Data System (ADS)
Ni, Zhuang; Liu, Kui; Kang, Guixia
2018-04-01
Distance metric learning algorithm has been widely applied to medical diagnosis and exhibited its strengths in classification problems. The k-nearest neighbour (KNN) is an efficient method which treats each feature equally. The large margin nearest neighbour classification (LMNN) improves the accuracy of KNN by learning a global distance metric, which did not consider the locality of data distributions. In this paper, we propose a new distance metric algorithm adopting cosine metric and LMNN named COS-SUBLMNN which takes more care about local feature of data to overcome the shortage of LMNN and improve the classification accuracy. The proposed methodology is verified on CVDs patient vector derived from real-world medical data. The Experimental results show that our method provides higher accuracy than KNN and LMNN did, which demonstrates the effectiveness of the Risk predictive model of CVDs based on COS-SUBLMNN.
Commissioning Procedures for Mechanical Precision and Accuracy in a Dedicated LINAC
DOE Office of Scientific and Technical Information (OSTI.GOV)
Ballesteros-Zebadua, P.; Larrga-Gutierrez, J. M.; Garcia-Garduno, O. A.
2008-08-11
Mechanical precision measurements are fundamental procedures for the commissioning of a dedicated LINAC. At our Radioneurosurgery Unit, these procedures can be suitable as quality assurance routines that allow the verification of the equipment geometrical accuracy and precision. In this work mechanical tests were performed for gantry and table rotation, obtaining mean associated uncertainties of 0.3 mm and 0.71 mm, respectively. Using an anthropomorphic phantom and a series of localized surface markers, isocenter accuracy showed to be smaller than 0.86 mm for radiosurgery procedures and 0.95 mm for fractionated treatments with mask. All uncertainties were below tolerances. The highest contribution tomore » mechanical variations is due to table rotation, so it is important to correct variations using a localization frame with printed overlays. Mechanical precision knowledge would allow to consider the statistical errors in the treatment planning volume margins.« less
Multiple Ordinal Regression by Maximizing the Sum of Margins
Hamsici, Onur C.; Martinez, Aleix M.
2016-01-01
Human preferences are usually measured using ordinal variables. A system whose goal is to estimate the preferences of humans and their underlying decision mechanisms requires to learn the ordering of any given sample set. We consider the solution of this ordinal regression problem using a Support Vector Machine algorithm. Specifically, the goal is to learn a set of classifiers with common direction vectors and different biases correctly separating the ordered classes. Current algorithms are either required to solve a quadratic optimization problem, which is computationally expensive, or are based on maximizing the minimum margin (i.e., a fixed margin strategy) between a set of hyperplanes, which biases the solution to the closest margin. Another drawback of these strategies is that they are limited to order the classes using a single ranking variable (e.g., perceived length). In this paper, we define a multiple ordinal regression algorithm based on maximizing the sum of the margins between every consecutive class with respect to one or more rankings (e.g., perceived length and weight). We provide derivations of an efficient, easy-to-implement iterative solution using a Sequential Minimal Optimization procedure. We demonstrate the accuracy of our solutions in several datasets. In addition, we provide a key application of our algorithms in estimating human subjects’ ordinal classification of attribute associations to object categories. We show that these ordinal associations perform better than the binary one typically employed in the literature. PMID:26529784
Program budgeting and marginal analysis: a case study in chronic airflow limitation.
Crockett, A; Cranston, J; Moss, J; Scown, P; Mooney, G; Alpers, J
1999-01-01
Program budgeting and marginal analysis is a method of priority-setting in health care. This article describes how this method was applied to the management of a disease-specific group, chronic airflow limitation. A sub-program flow chart clarified the major cost drivers. After assessment of the technical efficiency of the sub-programs and careful and detailed analysis, incremental and decremental wish lists of activities were established. Program budgeting and marginal analysis provides a framework for rational resource allocation. The nurturing of a vigorous program management group, with members representing all participants in the process (including patients/consumers), is the key to a successful outcome.
Real-time image annotation by manifold-based biased Fisher discriminant analysis
NASA Astrophysics Data System (ADS)
Ji, Rongrong; Yao, Hongxun; Wang, Jicheng; Sun, Xiaoshuai; Liu, Xianming
2008-01-01
Automatic Linguistic Annotation is a promising solution to bridge the semantic gap in content-based image retrieval. However, two crucial issues are not well addressed in state-of-art annotation algorithms: 1. The Small Sample Size (3S) problem in keyword classifier/model learning; 2. Most of annotation algorithms can not extend to real-time online usage due to their low computational efficiencies. This paper presents a novel Manifold-based Biased Fisher Discriminant Analysis (MBFDA) algorithm to address these two issues by transductive semantic learning and keyword filtering. To address the 3S problem, Co-Training based Manifold learning is adopted for keyword model construction. To achieve real-time annotation, a Bias Fisher Discriminant Analysis (BFDA) based semantic feature reduction algorithm is presented for keyword confidence discrimination and semantic feature reduction. Different from all existing annotation methods, MBFDA views image annotation from a novel Eigen semantic feature (which corresponds to keywords) selection aspect. As demonstrated in experiments, our manifold-based biased Fisher discriminant analysis annotation algorithm outperforms classical and state-of-art annotation methods (1.K-NN Expansion; 2.One-to-All SVM; 3.PWC-SVM) in both computational time and annotation accuracy with a large margin.
Gillet, Jean-Pierre; Molina, Thierry Jo; Jamart, Jacques; Gaulard, Philippe; Leroy, Karen; Briere, Josette; Theate, Ivan; Thieblemont, Catherine; Bosly, Andre; Herin, Michel; Hamels, Jacques; Remacle, Jose
2009-03-01
Lymphomas are classified according to the World Health Organisation (WHO) classification which defines subtypes on the basis of clinical, morphological, immunophenotypic, molecular and cytogenetic criteria. Differential diagnosis of the subtypes is sometimes difficult, especially for small B-cell lymphoma (SBCL). Standardisation of molecular genetic assays using multiple gene expression analysis by microarrays could be a useful complement to the current diagnosis. The aim of the present study was to develop a low density DNA microarray for the analysis of 107 genes associated with B-cell non-Hodgkin lymphoma and to evaluate its performance in the diagnosis of SBCL. A predictive tool based on Fisher discriminant analysis using a training set of 40 patients including four different subtypes (follicular lymphoma n = 15, mantle cell lymphoma n = 7, B-cell chronic lymphocytic leukemia n = 6 and splenic marginal zone lymphoma n = 12) was designed. A short additional preliminary analysis to gauge the accuracy of this signature was then performed on an external set of nine patients. Using this model, eight of nine of those samples were classified successfully. This pilot study demonstrates that such a microarray tool may be a promising diagnostic approach for small B-cell non-Hodgkin lymphoma.
Lee, Pius; Liu, Yang
2014-01-01
We report the progress of an ongoing effort by the Air Resources Laboratory, NOAA to build a prototype regional Chemical Analysis System (ARLCAS). The ARLCAS focuses on providing long-term analysis of the three dimensional (3D) air-pollutant concentration fields over the continental U.S. It leverages expertise from the NASA Earth Science Division-sponsored Air Quality Applied Science Team (AQAST) for the state-of-science knowledge in atmospheric and data assimilation sciences. The ARLCAS complies with national operational center requirement protocols and aims to have the modeling system to be maintained by a national center. Meteorology and chemistry observations consist of land-, air- and space-based observed and quality-assured data. We develop modularized testing to investigate the efficacies of the various components of the ARLCAS. The sensitivity testing of data assimilation schemes showed that with the increment of additional observational data sets, the accuracy of the analysis chemical fields also increased incrementally in varying margins. The benefit is especially noted for additional data sets based on a different platform and/or a different retrieval algorithm. We also described a plan to apply the analysis chemical fields in environmental surveillance at the Centers for Disease Control and Prevention. PMID:25514141
Lee, Pius; Liu, Yang
2014-12-01
We report the progress of an ongoing effort by the Air Resources Laboratory, NOAA to build a prototype regional Chemical Analysis System (ARLCAS). The ARLCAS focuses on providing long-term analysis of the three dimensional (3D) air-pollutant concentration fields over the continental U.S. It leverages expertise from the NASA Earth Science Division-sponsored Air Quality Applied Science Team (AQAST) for the state-of-science knowledge in atmospheric and data assimilation sciences. The ARLCAS complies with national operational center requirement protocols and aims to have the modeling system to be maintained by a national center. Meteorology and chemistry observations consist of land-, air- and space-based observed and quality-assured data. We develop modularized testing to investigate the efficacies of the various components of the ARLCAS. The sensitivity testing of data assimilation schemes showed that with the increment of additional observational data sets, the accuracy of the analysis chemical fields also increased incrementally in varying margins. The benefit is especially noted for additional data sets based on a different platform and/or a different retrieval algorithm. We also described a plan to apply the analysis chemical fields in environmental surveillance at the Centers for Disease Control and Prevention.
NASA Astrophysics Data System (ADS)
Kazem Alavipanah, Seyed
There are some problems in soil salinity studies based upon remotely sensed data: 1-spectral world is full of ambiguity and therefore soil reflectance can not be attributed to a single soil property such as salinity, 2) soil surface conditions as a function of time and space is a complex phenomena, 3) vegetation with a dynamic biological nature may create some problems in the study of soil salinity. Due to these problems the first question which may arise is how to overcome or minimise these problems. In this study we hypothesised that different sources of data, well established sampling plan and optimum approach could be useful. In order to choose representative training sites in the Iranian playa margins, to define the spectral and informational classes and to overcome some problems encountered in the variation within the field, the following attempts were made: 1) Principal Component Analysis (PCA) in order: a) to determine the most important variables, b) to understand the Landsat satellite images and the most informative components, 2) the photomorphic unit (PMU) consideration and interpretation; 3) study of salt accumulation and salt distribution in the soil profile, 4) use of several forms of field data, such as geologic, geomorphologic and soil information; 6) confirmation of field data and land cover types with farmers and the members of the team. The results led us to find at suitable approaches with a high and acceptable image classification accuracy and image interpretation. KEY WORDS; Photo Morphic Unit, Pprincipal Ccomponent Analysis, Soil Salinity, Field Work, Remote Sensing
Utilizing Flight Data to Update Aeroelastic Stability Estimates
NASA Technical Reports Server (NTRS)
Lind, Rick; Brenner, Marty
1997-01-01
Stability analysis of high performance aircraft must account for errors in the system model. A method for computing flutter margins that incorporates flight data has been developed using robust stability theory. This paper considers applying this method to update flutter margins during a post-flight or on-line analysis. Areas of modeling uncertainty that arise when using flight data with this method are investigated. The amount of conservatism in the resulting flutter margins depends on the flight data sets used to update the model. Post-flight updates of flutter margins for an F/A-18 are presented along with a simulation of on-line updates during a flight test.
NASA Technical Reports Server (NTRS)
Austin, L. D., Jr.
1977-01-01
The results are documented of an analysis conducted to determine space shuttle vehicle (SSV) subsystem margins for the reference flight profile for the first orbital flight test (OFT-1). In general, the results show increased margins for the OFT-1 indicators when compared to Mission 3A resutls. The inclusion of element and wing aerodynamic variations on OFT-1, in combination with winds and systems dispersions, resulted in the forward Z (FTO1) attach load indicator exceeding specified limits. The inboard and outboard elevon hinge moment margins (9 percent and 3 percent, respectively) on OFT-1 reflect values consistent with the load relief requirements dictated by elevon hinge moment variations. All other structural load indicators for OFT-1 had margins in excess of 10 percent. The SSV first stage stagnation heating indicators for OFT-1 were about 45 percent less than for Mission 3A. The hydraulic systems demands for both missions were essentially the same. The results also show OFT-1 performance requirements from the consideration of winds and dispersions to be approximately 3,300 lbs greater than Mission 3A.
Evaluation of marginal fit of two all-ceramic copings with two finish lines
Subasi, Gulce; Ozturk, Nilgun; Inan, Ozgur; Bozogullari, Nalan
2012-01-01
Objectives: This in-vitro study investigated the marginal fit of two all-ceramic copings with 2 finish line designs. Methods: Forty machined stainless steel molar die models with two different margin designs (chamfer and rounded shoulder) were prepared. A total of 40 standardized copings were fabricated and divided into 4 groups (n=10 for each finish line-coping material). Coping materials tested were IPS e.max Press and Zirkonzahn; luting agent was Variolink II. Marginal fit was evaluated after cementation with a stereomicroscope (Leica MZ16). Two-way analysis of variance and Tukey-HSD test were performed to assess the influence of each finish line design and ceramic type on the marginal fit of 2 all-ceramic copings (α =.05). Results: Two-way analysis of variance revealed no statistically significant differences for marginal fit relative to finish lines (P=.362) and ceramic types (P=.065). Conclusion: Within the limitations of this study, both types of all-ceramic copings demonstrated that the mean marginal fit was considered acceptable for clinical application (⩽120 μm). PMID:22509119
The Role of Margin in Link Design and Optimization
NASA Technical Reports Server (NTRS)
Cheung, K.
2015-01-01
Link analysis is a system engineering process in the design, development, and operation of communication systems and networks. Link models that are mathematical abstractions representing the useful signal power and the undesirable noise and attenuation effects (including weather effects if the signal path transverses through the atmosphere) that are integrated into the link budget calculation that provides the estimates of signal power and noise power at the receiver. Then the link margin is applied which attempts to counteract the fluctuations of the signal and noise power to ensure reliable data delivery from transmitter to receiver. (Link margin is dictated by the link margin policy or requirements.) A simple link budgeting approach assumes link parameters to be deterministic values typically adopted a rule-of-thumb policy of 3 dB link margin. This policy works for most S- and X-band links due to their insensitivity to weather effects. But for higher frequency links like Ka-band, Ku-band, and optical communication links, it is unclear if a 3 dB link margin would guarantee link closure. Statistical link analysis that adopted the 2-sigma or 3-sigma link margin incorporates link uncertainties in the sigma calculation. (The Deep Space Network (DSN) link margin policies are 2-sigma for downlink and 3-sigma for uplink.) The link reliability can therefore be quantified statistically even for higher frequency links. However in the current statistical link analysis approach, link reliability is only expressed as the likelihood of exceeding the signal-to-noise ratio (SNR) threshold that corresponds to a given bit-error-rate (BER) or frame-error-rate (FER) requirement. The method does not provide the true BER or FER estimate of the link with margin, or the required signalto-noise ratio (SNR) that would meet the BER or FER requirement in the statistical sense. In this paper, we perform in-depth analysis on the relationship between BER/FER requirement, operating SNR, and coding performance curve, in the case when the channel coherence time of link fluctuation is comparable or larger than the time duration of a codeword. We compute the "true" SNR design point that would meet the BER/FER requirement by taking into account the fluctuation of signal power and noise power at the receiver, and the shape of the coding performance curve. This analysis yields a number of valuable insights on the design choices of coding scheme and link margin for the reliable data delivery of a communication system - space and ground. We illustrate the aforementioned analysis using a number of standard NASA error-correcting codes.
A novel double fine guide sensor design on space telescope
NASA Astrophysics Data System (ADS)
Zhang, Xu-xu; Yin, Da-yi
2018-02-01
To get high precision attitude for space telescope, a double marginal FOV (field of view) FGS (Fine Guide Sensor) is proposed. It is composed of two large area APS CMOS sensors and both share the same lens in main light of sight. More star vectors can be get by two FGS and be used for high precision attitude determination. To improve star identification speed, the vector cross product in inter-star angles for small marginal FOV different from traditional way is elaborated and parallel processing method is applied to pyramid algorithm. The star vectors from two sensors are then used to attitude fusion with traditional QUEST algorithm. The simulation results show that the system can get high accuracy three axis attitudes and the scheme is feasibility.
Yao, Lihong; Zhu, Lihong; Wang, Junjie; Liu, Lu; Zhou, Shun; Jiang, ShuKun; Cao, Qianqian; Qu, Ang; Tian, Suqing
2015-04-26
To improve the delivery of radiotherapy in gynecologic malignancies and to minimize the irradiation of unaffected tissues by using daily kilovoltage cone beam computed tomography (kV-CBCT) to reduce setup errors. Thirteen patients with gynecologic cancers were treated with postoperative volumetric-modulated arc therapy (VMAT). All patients had a planning CT scan and daily CBCT during treatment. Automatic bone anatomy matching was used to determine initial inter-fraction positioning error. Positional correction on a six-degrees-of-freedom (6DoF) couch was followed by a second scan to calculate the residual inter-fraction error, and a post-treatment scan assessed intra-fraction motion. The margins of the planning target volume (MPTV) were calculated from these setup variations and the effect of margin size on normal tissue sparing was evaluated. In total, 573 CBCT scans were acquired. Mean absolute pre-/post-correction errors were obtained in all six planes. With 6DoF couch correction, the MPTV accounting for intra-fraction errors was reduced by 3.8-5.6 mm. This permitted a reduction in the maximum dose to the small intestine, bladder and femoral head (P=0.001, 0.035 and 0.032, respectively), the average dose to the rectum, small intestine, bladder and pelvic marrow (P=0.003, 0.000, 0.001 and 0.000, respectively) and markedly reduced irradiated normal tissue volumes. A 6DoF couch in combination with daily kV-CBCT can considerably improve positioning accuracy during VMAT treatment in gynecologic malignancies, reducing the MPTV. The reduced margin size permits improved normal tissue sparing and a smaller total irradiated volume.
NASA Astrophysics Data System (ADS)
Fei, Baowei; Lu, Guolan; Wang, Xu; Zhang, Hongzheng; Little, James V.; Patel, Mihir R.; Griffith, Christopher C.; El-Diery, Mark W.; Chen, Amy Y.
2017-08-01
A label-free, hyperspectral imaging (HSI) approach has been proposed for tumor margin assessment. HSI data, i.e., hypercube (x,y,λ), consist of a series of high-resolution images of the same field of view that are acquired at different wavelengths. Every pixel on an HSI image has an optical spectrum. In this pilot clinical study, a pipeline of a machine-learning-based quantification method for HSI data was implemented and evaluated in patient specimens. Spectral features from HSI data were used for the classification of cancer and normal tissue. Surgical tissue specimens were collected from 16 human patients who underwent head and neck (H&N) cancer surgery. HSI, autofluorescence images, and fluorescence images with 2-deoxy-2-[(7-nitro-2,1,3-benzoxadiazol-4-yl)amino]-D-glucose (2-NBDG) and proflavine were acquired from each specimen. Digitized histologic slides were examined by an H&N pathologist. The HSI and classification method were able to distinguish between cancer and normal tissue from the oral cavity with an average accuracy of 90%±8%, sensitivity of 89%±9%, and specificity of 91%±6%. For tissue specimens from the thyroid, the method achieved an average accuracy of 94%±6%, sensitivity of 94%±6%, and specificity of 95%±6%. HSI outperformed autofluorescence imaging or fluorescence imaging with vital dye (2-NBDG or proflavine). This study demonstrated the feasibility of label-free, HSI for tumor margin assessment in surgical tissue specimens of H&N cancer patients. Further development of the HSI technology is warranted for its application in image-guided surgery.
Mann, Karsten; Davids, Andreas; Range, Ursula; Richter, Gert; Boening, Klaus; Reitemeier, Bernd
2015-04-01
The 2-step putty and wash impression technique is commonly used in fixed prosthodontics. However, cutting sluiceways to allow the light-body material to drain is time-consuming. A solution might be the use of a spacer foil. The purpose of this study was to evaluate the influence of spacer foil on the margin reproduction and dimensional accuracy of 2-step putty and wash impressions. Two methods of creating space for the wash material in a 2-step putty and wash impression were compared: the traditional cutout technique and a spacer foil. Eleven commercially available combinations of silicone impression materials were included in the study. The impressions and the cast production were carried out under standardized conditions. All casts were measured with a 3-dimensional (3D) coordinate measuring machine. Preparation margin reproduction and the diameters and spacing of the stone cast dies were measured (α=.05). The 2 methods showed significant differences (P<.05) in the reproduction of the preparation margins (complete reproduction cutout, 90% to 98%; foil, 74% to 91%). The use of a foil resulted in greater dimensional accuracy of the cast dies compared to the cutout technique. Cast dies from the cutout technique were significantly smaller than the metallic original cast (cutout median, 4.55 mm to 4.61 mm; foil median, 4.61 to 4.64). Spacing between the dies revealed only a few additional significant differences between the techniques. When spacer foils were used, dies were obtained that better corresponded to the original tooth. Copyright © 2015 Editorial Council for the Journal of Prosthetic Dentistry. Published by Elsevier Inc. All rights reserved.
Prasad, Rahul; Al-Keraif, Abdulaziz Abdullah; Kathuria, Nidhi; Gandhi, P V; Bhide, S V
2014-02-01
The purpose of this study was to determine whether the ringless casting and accelerated wax-elimination techniques can be combined to offer a cost-effective, clinically acceptable, and time-saving alternative for fabricating single unit castings in fixed prosthodontics. Sixty standardized wax copings were fabricated on a type IV stone replica of a stainless steel die. The wax patterns were divided into four groups. The first group was cast using the ringless investment technique and conventional wax-elimination method; the second group was cast using the ringless investment technique and accelerated wax-elimination method; the third group was cast using the conventional metal ring investment technique and conventional wax-elimination method; the fourth group was cast using the metal ring investment technique and accelerated wax-elimination method. The vertical marginal gap was measured at four sites per specimen, using a digital optical microscope at 100× magnification. The results were analyzed using two-way ANOVA to determine statistical significance. The vertical marginal gaps of castings fabricated using the ringless technique (76.98 ± 7.59 μm) were significantly less (p < 0.05) than those castings fabricated using the conventional metal ring technique (138.44 ± 28.59 μm); however, the vertical marginal gaps of the conventional (102.63 ± 36.12 μm) and accelerated wax-elimination (112.79 ± 38.34 μm) castings were not statistically significant (p > 0.05). The ringless investment technique can produce castings with higher accuracy and can be favorably combined with the accelerated wax-elimination method as a vital alternative to the time-consuming conventional technique of casting restorations in fixed prosthodontics. © 2013 by the American College of Prosthodontists.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Courneyea, L; Mullins, J; Howard, M
2014-08-15
Purpose: Evaluate an immobilization system to determine its adequacy for the reduced margins required for proton therapy. Methods: Twelve head-and-neck cancer patients were immobilized for conventional photon radiotherapy and imaged with pre- and post-treatment cone beam CTs (CBCTs) for each treatment fraction. To quantify the patient positioning reproducibility, each CBCT was registered to the simulation CT offline. Registrations were performed using auto-match tools and a matching volume-of-interest (VOI) consisting of a 5mm expansion around the mandible, occipital bone, C1/C2 and C7/T1. For each registration, the bony anatomy in the VOI was evaluated for agreement with the simulation position using 3more » and 5mm margins. Registrations were initially restricted to translational corrections. If the bony anatomy did not agree with the simulation position to within 3mm or 5mm, the auto-match was repeated with 3 additional rotational corrections. Intrafraction motion was calculated as the difference between the pre- and post-treatment CBCT matches. Results: Pre-treatment patient positioning agreed with the simulation CT to within 3mm/5mm for 62%/86% of fractions using translational matching and 84%/100% of fractions when rotations were included. Intrafraction motion averaged 1.1±0.8mm, with 12% of fractions having >2mm intrafraction motion. Post-treatment positioning accuracy was 57%/84% and 80%/100% for registrations without/with rotations. For the mandible, positioning accuracy dropped from 93% pre-treatment to 82% post-treatment. Conclusion: If rotational corrections are available, the immobilization system studied created reproducible patient positioning to within 3mm for 84% of fractions. However, intrafraction motion caused additional anatomy to fall outside the 3mm margin by the end of treatment.« less
Kim, Kyung Su; Kwon, Jeanny; Kim, Kyubo; Chie, Eui Kyu
2017-01-01
Purpose While curative resection is the only chance of cure in pancreatic cancer, controversies exist about the impact of surgical margin status on survival. Non-standardized pathologic report and different criteria on the R1 status made it difficult to implicate adjuvant therapy after resection based on the margin status. We evaluated the influence of resection margins on survival by meta-analysis. Materials and Methods We thoroughly searched electronic databases of PubMed, EMBASE, and Cochrane Library. We included studies reporting survival outcomes with different margin status: involved margin (R0 mm), margin clearance with ≤ 1 mm (R0-1 mm), and margin with > 1 mm (R>1 mm). Hazard ratio (HR) for overall survival was extracted, and a random-effects model was used for pooled analysis. Results A total of eight retrospective studies involving 1,932 patients were included. Pooled HR for overall survival showed that patients with R>1 mm had reduced risk of death than those with R0-1 mm (HR, 0.74; 95% confidence interval [CI], 0.61 to 0.88; p=0.001). In addition, patients with R0-1 mm had reduced risk of death than those with R0 mm (HR, 0.81; 95% CI, 0.72 to 0.91; p < 0.001). There was no heterogeneity between the included studies (I2 index, 42% and 0%; p=0.10 and p=0.82, respectively). Conclusion Our results suggest that stratification of the patients based on margin status is warranted in the clinical trials assessing the role of adjuvant treatment for pancreatic cancer. PMID:27561314
Kricheldorf, Fabio; Bueno, Cleuber Rodrigo de Souza; Amaral, Wilson da Silva; Junior, Joel Ferreira Santiago; Filho, Hugo Nary
2018-01-01
The objective of this study is to compare the marginal adaptation of feldspathic porcelain crowns using two computer-aided design/computer-aided manufacturing systems, one of them is open and the other is closed. Twenty identical titanium abutments were divided into two groups: open system (OS), where ceramic crowns were created using varied equipment and software, and closed system (CS), where ceramic crowns were created using the CEREC system. Through optical microscopy analysis, we assess the marginal adaptation of the prosthetic interfaces. The data were subjected to the distribution of normality and variance. The t -test was used for the analysis of the comparison factor between the groups, and the one-way ANOVA was used to compare the variance of crown analysis regions within the group. A significance level of 5% was considered for the analyses. There was a significant difference between the systems ( P = 0.007), with the CS group having the higher mean (23.75 μm ± 3.05) of marginal discrepancy when compared to the open group (17.94 μm ± 4.77). Furthermore, there were no differences in marginal discrepancy between the different points between the groups ( P ≥ 0.05). The studied groups presented results within the requirements set out in the literature. However, the OS used presented better results in marginal adaptation.
2011-01-01
Background Taking intraoperative frozen sections (FS) is a widely used procedure in oncologic surgery. However so far no evidence of an association of FS analysis and premalignant changes in the surgical margin exists. Therefore, the aim of this study was to evaluate the impact of FS on different categories of the final margins of squamous cell carcinoma (SCC) of the oral cavity and lips. Methods FS, pT-stage, grading, and tumor localization of 178 patients with SCC of the oral cavity and lips were compared by uni- and multivariate analysis in patients with positive, dysplastic and negative surgical margin status. Results Performed on 111 patients (62.4%), intraoperative FS did not have any statistically significant influence on final margin status, independent of whether it was positive (p = 0.40), dysplastic (p = 0.70), or negative (p = 0.70). Positive surgical margins in permanent sections were significantly associated with pT4-tumors (OR 5.61, p = 0.001). The chance for negative margins in permanent sections was significantly higher in tumors located in the tongue (OR 4.70, p = 0.01). Conclusions Our data suggests that intraoperative FS in SCC can be useful in selected cases. However it is not advisable as a routine approach. PMID:22208692
Kappa and Rater Accuracy: Paradigms and Parameters.
Conger, Anthony J
2017-12-01
Drawing parallels to classical test theory, this article clarifies the difference between rater accuracy and reliability and demonstrates how category marginal frequencies affect rater agreement and Cohen's kappa (κ). Category assignment paradigms are developed: comparing raters to a standard (index) versus comparing two raters to one another (concordance), using both nonstochastic and stochastic category membership. Using a probability model to express category assignments in terms of rater accuracy and random error, it is shown that observed agreement (Po) depends only on rater accuracy and number of categories; however, expected agreement (Pe) and κ depend additionally on category frequencies. Moreover, category frequencies affect Pe and κ solely through the variance of the category proportions, regardless of the specific frequencies underlying the variance. Paradoxically, some judgment paradigms involving stochastic categories are shown to yield higher κ values than their nonstochastic counterparts. Using the stated probability model, assignments to categories were generated for 552 combinations of paradigms, rater and category parameters, category frequencies, and number of stimuli. Observed means and standard errors for Po, Pe, and κ were fully consistent with theory expectations. Guidelines for interpretation of rater accuracy and reliability are offered, along with a discussion of alternatives to the basic model.
Independent Component Analysis of Textures
NASA Technical Reports Server (NTRS)
Manduchi, Roberto; Portilla, Javier
2000-01-01
A common method for texture representation is to use the marginal probability densities over the outputs of a set of multi-orientation, multi-scale filters as a description of the texture. We propose a technique, based on Independent Components Analysis, for choosing the set of filters that yield the most informative marginals, meaning that the product over the marginals most closely approximates the joint probability density function of the filter outputs. The algorithm is implemented using a steerable filter space. Experiments involving both texture classification and synthesis show that compared to Principal Components Analysis, ICA provides superior performance for modeling of natural and synthetic textures.
Alici, Ibrahim Onur; Yılmaz Demirci, Nilgün; Yılmaz, Aydın; Karakaya, Jale; Özaydın, Esra
2016-09-01
There are several papers on the sonographic features of mediastinal lymph nodes affected by several diseases, but none gives the importance and clinical utility of the features. In order to find out which lymph node should be sampled in a particular nodal station during endobronchial ultrasound, we investigated the diagnostic performances of certain sonographic features and proposed an algorithmic approach. We retrospectively analyzed 1051 lymph nodes and randomly assigned them into a preliminary experimental and a secondary study group. The diagnostic performances of the sonographic features (gray scale, echogeneity, shape, size, margin, presence of necrosis, presence of calcification and absence of central hilar structure) were calculated, and an algorithm for lymph node sampling was obtained with decision tree analysis in the experimental group. Later, a modified algorithm was applied to the patients in the study group to give the accuracy. The demographic characteristics of the patients were not statistically significant between the primary and the secondary groups. All of the features were discriminative between malignant and benign diseases. The modified algorithm sensitivity, specificity, and positive and negative predictive values and diagnostic accuracy for detecting metastatic lymph nodes were 100%, 51.2%, 50.6%, 100% and 67.5%, respectively. In this retrospective analysis, the standardized sonographic classification system and the proposed algorithm performed well in choosing the node that should be sampled in a particular station during endobronchial ultrasound. © 2015 John Wiley & Sons Ltd.
Cluster-based analysis improves predictive validity of spike-triggered receptive field estimates
Malone, Brian J.
2017-01-01
Spectrotemporal receptive field (STRF) characterization is a central goal of auditory physiology. STRFs are often approximated by the spike-triggered average (STA), which reflects the average stimulus preceding a spike. In many cases, the raw STA is subjected to a threshold defined by gain values expected by chance. However, such correction methods have not been universally adopted, and the consequences of specific gain-thresholding approaches have not been investigated systematically. Here, we evaluate two classes of statistical correction techniques, using the resulting STRF estimates to predict responses to a novel validation stimulus. The first, more traditional technique eliminated STRF pixels (time-frequency bins) with gain values expected by chance. This correction method yielded significant increases in prediction accuracy, including when the threshold setting was optimized for each unit. The second technique was a two-step thresholding procedure wherein clusters of contiguous pixels surviving an initial gain threshold were then subjected to a cluster mass threshold based on summed pixel values. This approach significantly improved upon even the best gain-thresholding techniques. Additional analyses suggested that allowing threshold settings to vary independently for excitatory and inhibitory subfields of the STRF resulted in only marginal additional gains, at best. In summary, augmenting reverse correlation techniques with principled statistical correction choices increased prediction accuracy by over 80% for multi-unit STRFs and by over 40% for single-unit STRFs, furthering the interpretational relevance of the recovered spectrotemporal filters for auditory systems analysis. PMID:28877194
Reddy, Nagam Raja; Reddy, Jakranpally Sathya; Padmaja, Bramha Josyula Indira; Reddy, Budigi Madan Mohan; Sunil, Motupalli; Reddy, Bommireddy Tejeswar
2016-01-01
To evaluate the accuracy of dies made from dual arch impressions using different sectional dual arch trays, combinations of elastomeric impression materials, and the sequence of pour of dies. The dual arch impression materials were grouped into three groups depending on the combination of impression materials used and each group is subdivided into four subgroups. A sample size of 8 in each subgroup yielding a total 96 impressions will be made into three groups of 32 each (Group I, II, and III). Group I constitute impressions made using monophase (M) impression material, Group II constitute impressions made using combination of heavy body and light body (HL), and Group III constitute impressions made using combination of putty and light body (PL). Dies obtained were evaluated with a travelling microscope to measure the buccolingual width of the tooth at the margin by using the sharp corners of the notches as reference points. Descriptive analysis namely mean and standard deviation, one-way analysis of variance test. The results obtained in this study indicate that though not statistically significant, the metal dual arch trays performed better when compared to the plastic trays in reproducing die dimensions. From the results obtained, dies poured from combination of heavy body and light body impressions using plastic or metal dual arch trays showed least variation in bucco-lingual dimension from master model.
Kim, Dong Wook
2015-08-01
The aim of this study was to compare the diagnostic accuracy of real-time and static ultrasonography (US) for the incidental detection of diffuse thyroid disease (DTD). In 118 consecutive patients, a single radiologist performed real-time US before thyroidectomy. For static US, the same radiologist retrospectively investigated the sonographic findings on a picture-archiving and communication system after 3 months. The diagnostic categories of both real-time and static US diagnoses were determined based on the number of abnormal findings, and the diagnostic indices were calculated by a receiver operating characteristic (ROC) curve analysis using the histopathologic results as the reference standard. Histopathologic results included normal thyroid (n = 77), Hashimoto thyroiditis (n = 11), non-Hashimoto lymphocytic thyroiditis (n = 29), and diffuse hyperplasia (n = 1). Normal thyroid and DTD showed significant differences in echogenicity, echotexture, glandular margin, and vascularity on both real-time and static US. There was a positive correlation between US categories and histopathologic results in both real-time and static US. The highest diagnostic indices were obtained when the cutoff criteria of real-time and static US diagnoses were chosen as indeterminate and suspicious for DTD, respectively. The ROC curve analysis showed that real-time US was superior to static US in diagnostic accuracy. Both real-time and static US may be helpful for the detection of incidental DTD, but real-time US is superior to static US for detecting incidental DTD.
Loft, Shayne; Bolland, Scott; Humphreys, Michael S; Neal, Andrew
2009-06-01
A performance theory for conflict detection in air traffic control is presented that specifies how controllers adapt decisions to compensate for environmental constraints. This theory is then used as a framework for a model that can fit controller intervention decisions. The performance theory proposes that controllers apply safety margins to ensure separation between aircraft. These safety margins are formed through experience and reflect the biasing of decisions to favor safety over accuracy, as well as expectations regarding uncertainty in aircraft trajectory. In 2 experiments, controllers indicated whether they would intervene to ensure separation between pairs of aircraft. The model closely predicted the probability of controller intervention across the geometry of problems and as a function of controller experience. When controller safety margins were manipulated via task instructions, the parameters of the model changed in the predicted direction. The strength of the model over existing and alternative models is that it better captures the uncertainty and decision biases involved in the process of conflict detection. (PsycINFO Database Record (c) 2009 APA, all rights reserved).
Structure of the North American Atlantic Continental Margin.
ERIC Educational Resources Information Center
Klitgord, K. K.; Schlee, J. S.
1986-01-01
Offers explanations on the origin of the North American Atlantic continental margin. Provides an analysis and illustrations of structural and strategraphic elements of cross sections of the Atlantic continental margin. Also explains the operations and applications of seismic-relection profiles in studying ocean areas. (ML)
Öbek, Can; Saglican, Yesim; Ince, Umit; Argun, Omer Burak; Tuna, Mustafa Bilal; Doganca, Tunkut; Tufek, Ilter; Keskin, Selcuk; Kural, Ali Riza
2018-04-01
To demonstrate a novel frozen section analysis technique during robot assisted radical prostatectomy with 2 distinct advantages: evaluation of the entire circumference and easier reconstruction for whole mount evaluation. Istanbul Preserve was performed on patients who underwent robotic prostatectomy with nerve sparing between 10/2014 and 7/2016. Gland was sectioned at 3-4mm intervals from apex to bladder neck. Entire tissue representing margins (except for the most anterior portion) was circumferentially excised and microscopically analyzed. In margin positivity, approach was individualized based on extent of positive margin and Gleason pattern. A matched cohort was established for comparison. Retrospective analysis of a prospectively maintained database was performed. Impact of FSA on PSM rate was primarily assessed. Data on 170 patients was analyzed. Positive surgical margin was reported in 56(33%) on frozen section. Neurovascular bundle was partially or totally resected in 79% and 18%. Conversion of positive margin to negative was achieved in 85%. Overall positive margin rate decreased from 22.5% to 7.5%. Nerve sparing increased from 87% to 93%. Location of positive margin at frozen was at the neurovascular bundle area in 39%; thus Istanbul Preserve detected 61% additional margin positivity compared to other techniques. Reconstruction for whole mount was easy. Istanbul Preserve is a novel technique for intraoperative FSA during RARP allowing for microscopic examination of the entire prostate for margin status and easy re-construction for whole mount examination. It guarantees safer margins together with increased rate of nerve sparing. Copyright © 2017 Elsevier Inc. All rights reserved.
Li, Kai; Su, Zhongzhen; Xu, Erjiao; Huang, Qiannan; Zeng, Qingjing; Zheng, Rongqin
2017-01-19
To assess the accuracy of contrast-enhanced ultrasound (CEUS)-CT/MR image fusion in evaluating the radiofrequency ablative margin (AM) of hepatocellular carcinoma (HCC) based on a custom-made phantom model and in HCC patients. Twenty-four phantoms were randomly divided into a complete ablation group (n = 6) and an incomplete ablation group (n = 18). After radiofrequency ablation (RFA), the AM was evaluated using ultrasound (US)-CT image fusion, and the results were compared with the AM results that were directly measured in a gross specimen. CEUS-CT/MR image fusion and CT-CT / MR-MR image fusion were used to evaluate the AM in 37 tumors from 33 HCC patients who underwent RFA. The sensitivity, specificity, and accuracy of US-CT image fusion for evaluating AM in the phantom model were 93.8, 85.7 and 91.3%, respectively. The maximal thicknesses of the residual AM were 3.5 ± 2.0 mm and 3.2 ± 2.0 mm in the US-CT image fusion and gross specimen, respectively. No significant difference was observed between the US-CT image fusion and direct measurements of the AM of HCC. In the clinical study, the success rate of the AM evaluation was 100% for both CEUS-CT/MR and CT-CT/MR-MR, and the duration was 8.5 ± 2.8 min (range: 4-12 min) and 13.5 ± 4.5 min (range: 8-16 min) for CEUS-CT/MR and CT-CT/MR-MR, respectively. The sensitivity, specificity, and accuracy of CEUS-CT/MR imaging for evaluating the AM were 100.0, 80.0, and 90.0%, respectively. A phantom model composed of carrageenan gel and additives was suitable for the evaluation of HCC AM. CEUS-CT/MR image fusion can be used to evaluate HCC AM with high accuracy.
Evaluation of target coverage and margins adequacy during CyberKnife Lung Optimized Treatment.
Ricotti, Rosalinda; Seregni, Matteo; Ciardo, Delia; Vigorito, Sabrina; Rondi, Elena; Piperno, Gaia; Ferrari, Annamaria; Zerella, Maria Alessia; Arculeo, Simona; Francia, Claudia Maria; Sibio, Daniela; Cattani, Federica; De Marinis, Filippo; Spaggiari, Lorenzo; Orecchia, Roberto; Riboldi, Marco; Baroni, Guido; Jereczek-Fossa, Barbara Alicja
2018-04-01
Evaluation of target coverage and verification of safety margins, in motion management strategies implemented by Lung Optimized Treatment (LOT) module in CyberKnife system. Three fiducial-less motion management strategies provided by LOT can be selected according to tumor visibility in the X ray images acquired during treatment. In 2-view modality the tumor is visible in both X ray images and full motion tracking is performed. In 1-view modality the tumor is visible in a single X ray image, therefore, motion tracking is combined with an internal target volume (ITV)-based margin expansion. In 0-view modality the lesion is not visible, consequently the treatment relies entirely on an ITV-based approach. Data from 30 patients treated in 2-view modality were selected providing information on the three-dimensional tumor motion in correspondence to each X ray image. Treatments in 1-view and 0-view modalities were simulated by processing log files and planning volumes. Planning target volume (PTV) margins were defined according to the tracking modality: end-exhale clinical target volume (CTV) + 3 mm in 2-view and ITV + 5 mm in 0-view. In the 1-view scenario, the ITV encompasses only tumor motion along the non-visible direction. Then, non-uniform ITV to PTV margins were applied: 3 mm and 5 mm in the visible and non-visible direction, respectively. We defined the coverage of each voxel of the CTV as the percentage of X ray images where such voxel was included in the PTV. In 2-view modality coverage was calculated as the intersection between the CTV centred on the imaged target position and the PTV centred on the predicted target position, as recorded in log files. In 1-view modality, coverage was calculated as the intersection between the CTV centred on the imaged target position and the PTV centred on the projected predictor data. In 0-view modality coverage was calculated as the intersection between the CTV centred on the imaged target position and the non-moving PTV. Similar to dose-volume histogram, CTV coverage-volume histograms (defined as CVH) were derived for each patient and treatment modality. The geometric coverages of the 90% and 95% of CTV volume (C90, C95, respectively) were evaluated. Patient-specific optimal margins (ensuring C95 ≥ 95%) were computed retrospectively. The median ± interquartile-rage of C90 and C95 for upper lobe lesions was 99.1 ± 0.6% and 99.0 ± 3.1%, whereas they were 98.9 ± 4.2% and 97.8 ± 7.5% for lower and middle lobe tumors. In 2-view, 1-view and 0-view modality, adopted margins ensured C95 ≥ 95% in 70%, 85% and 63% of cases and C95 ≥ 90% in 90%, 88% and 83% of cases, respectively. In 2-view, 1-view and 0-view a reduction in margins still ensured C95 ≥ 95% in 33%, 78% and 59% of cases, respectively. CTV coverage analysis provided an a-posteriori evaluation of the treatment geometric accuracy and allowed a quantitative verification of the adequacy of the PTV margins applied in CyberKnife LOT treatments offering guidance in the selection of CTV margins. © 2018 American Association of Physicists in Medicine.
Fast max-margin clustering for unsupervised word sense disambiguation in biomedical texts
Duan, Weisi; Song, Min; Yates, Alexander
2009-01-01
Background We aim to solve the problem of determining word senses for ambiguous biomedical terms with minimal human effort. Methods We build a fully automated system for Word Sense Disambiguation by designing a system that does not require manually-constructed external resources or manually-labeled training examples except for a single ambiguous word. The system uses a novel and efficient graph-based algorithm to cluster words into groups that have the same meaning. Our algorithm follows the principle of finding a maximum margin between clusters, determining a split of the data that maximizes the minimum distance between pairs of data points belonging to two different clusters. Results On a test set of 21 ambiguous keywords from PubMed abstracts, our system has an average accuracy of 78%, outperforming a state-of-the-art unsupervised system by 2% and a baseline technique by 23%. On a standard data set from the National Library of Medicine, our system outperforms the baseline by 6% and comes within 5% of the accuracy of a supervised system. Conclusion Our system is a novel, state-of-the-art technique for efficiently finding word sense clusters, and does not require training data or human effort for each new word to be disambiguated. PMID:19344480
Wavelet Filtering to Reduce Conservatism in Aeroservoelastic Robust Stability Margins
NASA Technical Reports Server (NTRS)
Brenner, Marty; Lind, Rick
1998-01-01
Wavelet analysis for filtering and system identification was used to improve the estimation of aeroservoelastic stability margins. The conservatism of the robust stability margins was reduced with parametric and nonparametric time-frequency analysis of flight data in the model validation process. Nonparametric wavelet processing of data was used to reduce the effects of external desirableness and unmodeled dynamics. Parametric estimates of modal stability were also extracted using the wavelet transform. Computation of robust stability margins for stability boundary prediction depends on uncertainty descriptions derived from the data for model validation. F-18 high Alpha Research Vehicle aeroservoelastic flight test data demonstrated improved robust stability prediction by extension of the stability boundary beyond the flight regime.
Chang, Jenghwa
2017-06-01
To develop a statistical model that incorporates the treatment uncertainty from the rotational error of the single isocenter for multiple targets technique, and calculates the extra PTV (planning target volume) margin required to compensate for this error. The random vector for modeling the setup (S) error in the three-dimensional (3D) patient coordinate system was assumed to follow a 3D normal distribution with a zero mean, and standard deviations of σ x , σ y , σ z . It was further assumed that the rotation of clinical target volume (CTV) about the isocenter happens randomly and follows a three-dimensional (3D) independent normal distribution with a zero mean and a uniform standard deviation of σ δ . This rotation leads to a rotational random error (R), which also has a 3D independent normal distribution with a zero mean and a uniform standard deviation of σ R equal to the product of σδπ180 and dI⇔T, the distance between the isocenter and CTV. Both (S and R) random vectors were summed, normalized, and transformed to the spherical coordinates to derive the Chi distribution with three degrees of freedom for the radial coordinate of S+R. PTV margin was determined using the critical value of this distribution for a 0.05 significance level so that 95% of the time the treatment target would be covered by the prescription dose. The additional PTV margin required to compensate for the rotational error was calculated as a function of σ R and dI⇔T. The effect of the rotational error is more pronounced for treatments that require high accuracy/precision like stereotactic radiosurgery (SRS) or stereotactic body radiotherapy (SBRT). With a uniform 2-mm PTV margin (or σ x = σ y = σ z = 0.715 mm), a σ R = 0.328 mm will decrease the CTV coverage probability from 95.0% to 90.9%, or an additional 0.2-mm PTV margin is needed to prevent this loss of coverage. If we choose 0.2 mm as the threshold, any σ R > 0.328 mm will lead to an extra PTV margin that cannot be ignored, and the maximal σ δ that can be ignored is 0.45° (or 0.0079 rad ) for dI⇔T = 50 mm or 0.23° (or 0.004 rad ) for dI⇔T = 100 mm. The rotational error cannot be ignored for high-accuracy/-precision treatments like SRS/SBRT, particularly when the distance between the isocenter and target is large. © 2017 American Association of Physicists in Medicine.
Evaluation of marginal failures of dental composite restorations by acoustic emission analysis.
Gu, Ja-Uk; Choi, Nak-Sam
2013-01-01
In this study, a nondestructive method based on acoustic emission (AE) analysis was developed to evaluate the marginal failure states of dental composite restorations. Three types of ring-shaped substrates, which were modeled after a Class I cavity, were prepared from polymethyl methacrylate, stainless steel, and human molar teeth. A bonding agent and a composite resin were applied to the ring-shaped substrates and cured by light exposure. At each time-interval measurement, the tooth substrate presented a higher number of AE hits than polymethyl methacrylate and steel substrates. Marginal disintegration estimations derived from cumulative AE hits and cumulative AE energy parameters showed that a signification portion of marginal gap formation was already realized within 1 min at the initial light-curing stage. Estimation based on cumulative AE energy gave a higher level of marginal failure than that based on AE hits. It was concluded that the AE analysis method developed in this study was a viable approach in predicting the clinical survival of dental composite restorations efficiently within a short test period.
Street Sex Work: Re/Constructing Discourse from Margin to Center
ERIC Educational Resources Information Center
McCracken, Jill Linnette
2009-01-01
Newspaper media create interpretations of marginalized groups that require rhetorical analysis so that we can better understand these representations. This article focuses on how newspaper articles create interpretations of sex work that affect both the marginalized and mainstream communities. My ethnographic case study argues that the material…
Raghavendra, U; Rajendra Acharya, U; Gudigar, Anjan; Hong Tan, Jen; Fujita, Hamido; Hagiwara, Yuki; Molinari, Filippo; Kongmebhol, Pailin; Hoong Ng, Kwan
2017-05-01
Thyroid is a small gland situated at the anterior side of the neck and one of the largest glands of the endocrine system. The abrupt cell growth or malignancy in the thyroid gland may cause thyroid cancer. Ultrasound images distinctly represent benign and malignant lesions, but accuracy may be poor due to subjective interpretation. Computer Aided Diagnosis (CAD) can minimize the errors created due to subjective interpretation and assists to make fast accurate diagnosis. In this work, fusion of Spatial Gray Level Dependence Features (SGLDF) and fractal textures are used to decipher the intrinsic structure of benign and malignant thyroid lesions. These features are subjected to graph based Marginal Fisher Analysis (MFA) to reduce the number of features. The reduced features are subjected to various ranking methods and classifiers. We have achieved an average accuracy, sensitivity and specificity of 97.52%, 90.32% and 98.57% respectively using Support Vector Machine (SVM) classifier. The achieved maximum Area Under Curve (AUC) is 0.9445. Finally, Thyroid Clinical Risk Index (TCRI) a single number is developed using two MFA features to discriminate the two classes. This prototype system is ready to be tested with huge diverse database. Copyright © 2017 Elsevier B.V. All rights reserved.
An in-vitro investigation of the accuracy of fit of Procera and Empress crowns.
Fleming, Garry J R; Dobinson, Marie M; Landini, Gabriel; Harris, Jonathan J
2005-09-01
The current study aimed to investigate the accuracy of fit and the reproducibility of inner crown profile for two types of high strength ceramics, IPS Empress and Procera. Procera and Empress crowns with four different morphologies were cemented to dies using zinc phosphate dental cement. Vertical and horizontal sections were made through each of the crown/die preparations and images of the vertical sections were compared for curvature reproduction by alignment using image processing. Measurements were made on horizontal sections to determine cement layer thickness. Alignment of the crowns using image analysis identified quantifiable variations in the inner surface profile compared with the outer surface of the die. The largest differences occurred from the cusp tips to the occlusal adaptation area and differences in surface profile were less pronounced for Procera than Empress crowns. Marginal gap varied independently of ceramic or internal crown shape from 7-529 microm for Procera and 26-548 microm for Empress. IPS Empress has a superior ability to reproduce the inner surface profile of the crown morphologies investigated compared with Procera. The reduced reproduction of surface profile was associated with an increased cement thickness at the occlusal contact area that may inadvertently lead to failure of the crowns functional characteristics.
Alphan, Hakan
2011-11-01
The aim of this study is to compare various image algebra procedures for their efficiency in locating and identifying different types of landscape changes on the margin of a Mediterranean coastal plain, Cukurova, Turkey. Image differencing and ratioing were applied to the reflective bands of Landsat TM datasets acquired in 1984 and 2006. Normalized Difference Vegetation index (NDVI) and Principal Component Analysis (PCA) differencing were also applied. The resulting images were tested for their capacity to detect nine change phenomena, which were a priori defined in a three-level classification scheme. These change phenomena included agricultural encroachment, sand dune afforestation, coastline changes and removal/expansion of reed beds. The percentage overall accuracies of different algebra products for each phenomenon were calculated and compared. The results showed that some of the changes such as sand dune afforestation and reed bed expansion were detected with accuracies varying between 85 and 97% by the majority of the algebra operations, while some other changes such as logging could only be detected by mid-infrared (MIR) ratioing. For optimizing change detection in similar coastal landscapes, underlying causes of these changes were discussed and the guidelines for selecting band and algebra operations were provided. Copyright © 2011 Elsevier Ltd. All rights reserved.
On Time Delay Margin Estimation for Adaptive Control and Optimal Control Modification
NASA Technical Reports Server (NTRS)
Nguyen, Nhan T.
2011-01-01
This paper presents methods for estimating time delay margin for adaptive control of input delay systems with almost linear structured uncertainty. The bounded linear stability analysis method seeks to represent an adaptive law by a locally bounded linear approximation within a small time window. The time delay margin of this input delay system represents a local stability measure and is computed analytically by three methods: Pade approximation, Lyapunov-Krasovskii method, and the matrix measure method. These methods are applied to the standard model-reference adaptive control, s-modification adaptive law, and optimal control modification adaptive law. The windowing analysis results in non-unique estimates of the time delay margin since it is dependent on the length of a time window and parameters which vary from one time window to the next. The optimal control modification adaptive law overcomes this limitation in that, as the adaptive gain tends to infinity and if the matched uncertainty is linear, then the closed-loop input delay system tends to a LTI system. A lower bound of the time delay margin of this system can then be estimated uniquely without the need for the windowing analysis. Simulation results demonstrates the feasibility of the bounded linear stability method for time delay margin estimation.
Robust Stability Analysis of the Space Launch System Control Design: A Singular Value Approach
NASA Technical Reports Server (NTRS)
Pei, Jing; Newsome, Jerry R.
2015-01-01
Classical stability analysis consists of breaking the feedback loops one at a time and determining separately how much gain or phase variations would destabilize the stable nominal feedback system. For typical launch vehicle control design, classical control techniques are generally employed. In addition to stability margins, frequency domain Monte Carlo methods are used to evaluate the robustness of the design. However, such techniques were developed for Single-Input-Single-Output (SISO) systems and do not take into consideration the off-diagonal terms in the transfer function matrix of Multi-Input-Multi-Output (MIMO) systems. Robust stability analysis techniques such as H(sub infinity) and mu are applicable to MIMO systems but have not been adopted as standard practices within the launch vehicle controls community. This paper took advantage of a simple singular-value-based MIMO stability margin evaluation method based on work done by Mukhopadhyay and Newsom and applied it to the SLS high-fidelity dynamics model. The method computes a simultaneous multi-loop gain and phase margin that could be related back to classical margins. The results presented in this paper suggest that for the SLS system, traditional SISO stability margins are similar to the MIMO margins. This additional level of verification provides confidence in the robustness of the control design.
Margins in extra-abdominal desmoid tumors: a comparative analysis.
Leithner, Andreas; Gapp, Markus; Leithner, Katharina; Radl, Roman; Krippl, Peter; Beham, Alfred; Windhager, Reinhard
2004-06-01
The main treatment of extra-abdominal desmoid tumors remains surgery, but recurrence rates up to 80% are reported. The impact of microscopic surgical margin status according to the Enneking classification system is discussed controversially. Therefore, the authors screened the published literature for reliable data on the importance of a wide or radical excision of extra-abdominal desmoid tumors. All studies with more than ten patients, a surgical treatment only, and margin status stated were included. Only 12 out of 49 identified studies fulfilled the inclusion criteria. One hundred fifty-two primary tumors were excised with wide or radical microscopic surgical margins, while in 260 cases a marginal or intralesional excision was performed. In the first group 41 patients (27%) and in the second one 187 patients (72%) developed a recurrence. Therefore, microscopic surgical margin status according to the Enneking classification system is a significant prognostic factor (P < 0.001). The data of this review underline the strategy of a wide or radical local excision as the treatment of choice. Furthermore, as a large number of studies had to be excluded from this analysis, exact microscopic surgical margin status should be provided in future studies in order to allow comparability. . Copyright 2004 Wiley-Liss, Inc.
Bounded Linear Stability Analysis - A Time Delay Margin Estimation Approach for Adaptive Control
NASA Technical Reports Server (NTRS)
Nguyen, Nhan T.; Ishihara, Abraham K.; Krishnakumar, Kalmanje Srinlvas; Bakhtiari-Nejad, Maryam
2009-01-01
This paper presents a method for estimating time delay margin for model-reference adaptive control of systems with almost linear structured uncertainty. The bounded linear stability analysis method seeks to represent the conventional model-reference adaptive law by a locally bounded linear approximation within a small time window using the comparison lemma. The locally bounded linear approximation of the combined adaptive system is cast in a form of an input-time-delay differential equation over a small time window. The time delay margin of this system represents a local stability measure and is computed analytically by a matrix measure method, which provides a simple analytical technique for estimating an upper bound of time delay margin. Based on simulation results for a scalar model-reference adaptive control system, both the bounded linear stability method and the matrix measure method are seen to provide a reasonably accurate and yet not too conservative time delay margin estimation.
NASA Astrophysics Data System (ADS)
Cowie, L.; Kusznir, N. J.; Horn, B.
2013-12-01
Knowledge of ocean-continent transition (OCT) structure, continent-ocean boundary (COB) location and magmatic type are of critical importance for understanding rifted continental margin formation processes and in evaluating petroleum systems in deep-water frontier oil and gas exploration. The OCT structure, COB location and magmatic type of the SE Brazilian and S Angolan rifted continental margins are much debated; exhumed and serpentinised mantle have been reported at these margins. Integrated quantitative analysis using deep seismic reflection data and gravity inversion have been used to determine OCT structure, COB location and magmatic type for the SE Brazilian and S Angolan margins. Gravity inversion has been used to determine Moho depth, crustal basement thickness and continental lithosphere thinning. Residual Depth Anomaly (RDA) analysis has been used to investigate OCT bathymetric anomalies with respect to expected oceanic bathymetries and subsidence analysis has been used to determine the distribution of continental lithosphere thinning. These techniques have been validated on the Iberian margin for profiles IAM9 and ISE-01. In addition a joint inversion technique using deep seismic reflection and gravity anomaly data has been applied to the ION-GXT BS1-575 SE Brazil and ION-GXT CS1-2400 S Angola. The joint inversion method solves for coincident seismic and gravity Moho in the time domain and calculates the lateral variations in crustal basement densities and velocities along profile. Gravity inversion, RDA and subsidence analysis along the S Angolan ION-GXT CS1-2400 profile has been used to determine OCT structure and COB location. Analysis suggests that exhumed mantle, corresponding to a magma poor margin, is absent beneath the allochthonous salt. The thickness of earliest oceanic crust, derived from gravity and deep seismic reflection data is approximately 7km. The joint inversion predicts crustal basement densities and seismic velocities which are slightly less than expected for 'normal' oceanic crust. The difference between the sediment corrected RDA and that predicted from gravity inversion crustal thickness variation implies that this margin is experiencing ~300m of anomalous uplift attributed to mantle dynamic uplift. Gravity inversion, RDA and subsidence analysis have also been used to determine OCT structure and COB location along the ION-GXT BS1-575 profile, crossing the Sao Paulo Plateau and Florianopolis Ridge of the SE Brazilian margin. Gravity inversion, RDA and subsidence analysis predict the COB to be located SE of the Florianopolis Ridge. Analysis shows no evidence for exhumed mantle on this margin profile. The joint inversion technique predicts normal oceanic basement seismic velocities and densities and beneath the Sao Paulo Plateau and Florianopolis Ridge predicts crustal basement thicknesses between 10-15km. The Sao Paulo Plateau and Florianopolis Ridge are separated by a thin region of crustal basement beneath the salt interpreted as a regional transtensional structure. Sediment corrected RDAs and gravity derived 'synthetic' RDAs are of a similar magnitude on oceanic crust, implying negligible mantle dynamic topography.
CO2 laser versus cold steel margin analysis following endoscopic excision of glottic cancer
2014-01-01
Objective To compare the suitability of CO2 laser with steel instruments for margin excision in transoral laser microsurgery. Methods Prospective randomized blinded study. Patients with glottic cancer undergoing laser resection were randomized to margin excision by either steel instruments or CO2 laser. Margins were analyzed for size, interpretability and degree of artifact by a pathologist who was blinded to technique. Results 45 patients were enrolled in the study with 226 total margins taken. 39 margins taken by laser had marked artifact and 0 were uninterpretable. 20 margins taken by steel instruments had marked artifact, and 2 were uninterpretable. Controlling for margin size, the laser technique was associated with increasing degrees of margin artifact (p = 0.210), but there was no difference in crude rates of uninterpretability (p = 0.24). Conclusion Laser margin excision is associated with a greater degree of artifact than steel instrument excision, but was not associated with higher rate of uninterpretability. PMID:24502856
A primer on marginal effects-part II: health services research applications.
Onukwugha, E; Bergtold, J; Jain, R
2015-02-01
Marginal analysis evaluates changes in a regression function associated with a unit change in a relevant variable. The primary statistic of marginal analysis is the marginal effect (ME). The ME facilitates the examination of outcomes for defined patient profiles or individuals while measuring the change in original units (e.g., costs, probabilities). The ME has a long history in economics; however, it is not widely used in health services research despite its flexibility and ability to provide unique insights. This article, the second in a two-part series, discusses practical issues that arise in the estimation and interpretation of the ME for a variety of regression models often used in health services research. Part one provided an overview of prior studies discussing ME followed by derivation of ME formulas for various regression models relevant for health services research studies examining costs and utilization. The current article illustrates the calculation and interpretation of ME in practice and discusses practical issues that arise during the implementation, including: understanding differences between software packages in terms of functionality available for calculating the ME and its confidence interval, interpretation of average marginal effect versus marginal effect at the mean, and the difference between ME and relative effects (e.g., odds ratio). Programming code to calculate ME using SAS, STATA, LIMDEP, and MATLAB are also provided. The illustration, discussion, and application of ME in this two-part series support the conduct of future studies applying the concept of marginal analysis.
Antonson, Sibel A.; Yazici, A. Ruya; Okte, Zeynep; Villalta, Patricia; Antonson, Donald E.; Hardigan, Patrick C.
2012-01-01
Objective: To determine the relationship between margin preparation design and resin-composite type on microleakage with or without re-application of surface-penetrating sealant. Methods: Class-I resin-composite restorations were completed for 128 extracted human molars. Half of the margins were beveled, the other half, butt-joint. Half of each group was restored with Filtek-Supreme (FS), the other half with Esthet-X (EX) using their respective adhesive systems. Margins were etched and sealed with a surface-penetrating sealant, Fortify. The samples were stored in water 24h, and thermocycled (5,000 cycles, 5°C–55°C). Then, samples were abraded using a toothbrush machine (6,000 strokes). Half of the restorations from each sealant group (n=16) were resealed, and the other half had no further treatment. Thermocycling and tooth brushing were repeated. The samples were sealed with nail polish, immersed in methylene-blue for 8h, sectioned, and magnified digital photographs were taken. Three examiners assessed dye penetration. A 2×2×2 multi-layered Chi-Square analysis, using Cochran-Mantel-Haenszel test was conducted for statistical analysis. Results: No difference was observed between sealed and resealed FS and EX restorations with butt-joint margins. In beveled margins, resealing caused significantly less microleakage (P<.01). No differences were found between restorations either sealed or resealed with bevel margins. In butt-joint margins, at the leakage level deeper than 2/3 of the preparation depth, resealed FS showed less microleakage than EX resealed restorations (P<.01). Conclusion: Resealing reduced microleakage in bevel margins, however, in butt-joint margins resealing did not affect the leakage. A significant statistical relationship exists between and within resealing, margin preparation design, type of composite, and microleakage. PMID:23077418
2003-03-01
27 2.8.5 Marginal Analysis Method...Figure 11 Improved Configuration of Figure 10; Increases Basic System Reliability..... 26 Figure 12 Example of marginal analysis ...View of Main Book of Software ............................................................... 51 Figure 20 The View of Data Worksheet
Estimation Of TMDLs And Margin Of Safety Under Conditions Of Uncertainty
In TMDL development, an adequate margin of safety (MOS) is required in the calculation process to provide a cushion needed because of uncertainties in the data and analysis. Current practices, however, rarely factor analysis' uncertainty in TMDL development and the MOS is largel...
DOE Office of Scientific and Technical Information (OSTI.GOV)
Rottmann, J; Berbeco, R; Keall, P
Purpose: To maximize normal tissue sparing for treatments requiring motion encompassing margins. Motion mitigation techniques including DMLC or couch tracking can freeze tumor motion within the treatment aperture potentially allowing for smaller treatment margins and thus better sparing of normal tissue. To enable for a safe application of this concept in the clinic we propose adapting margins dynamically in real-time during radiotherapy delivery based on personalized tumor localization confidence. To demonstrate technical feasibility we present a phantom study. Methods: We utilize a realistic anthropomorphic dynamic thorax phantom with a lung tumor model embedded close to the spine. The tumor, amore » 3D-printout of a patient's GTV, is moved 15mm peak-to-peak by diaphragm compression and monitored by continuous EPID imaging in real-time. Two treatment apertures are created for each beam, one representing ITV -based and the other GTV-based margin expansion. A soft tissue localization (STiL) algorithm utilizing the continuous EPID images is employed to freeze tumor motion within the treatment aperture by means of DMLC tracking. Depending on a tracking confidence measure (TCM), the treatment aperture is adjusted between the ITV and the GTV leaf. Results: We successfully demonstrate real-time personalized margin adjustment in a phantom study. We measured a system latency of about 250 ms which we compensated by utilizing a respiratory motion prediction algorithm (ridge regression). With prediction in place we observe tracking accuracies better than 1mm. For TCM=0 (as during startup) an ITV-based treatment aperture is chosen, for TCM=1 a GTV-based aperture and for 0« less
NASA Astrophysics Data System (ADS)
Dahal, Sudhir
During tumor removal surgery, due to the problems associated with obtaining high-resolution, real-time chemical images of where exactly the tumor ends and healthy tissue begins (tumor margining), it is often necessary to remove a much larger volume of tissue than the tumor itself. In the case of brain tumor surgery, however, it is extremely unsafe to remove excess tissue. Therefore, without an accurate image of the tumor margins, some of the tumor's finger-like projections are inevitably left behind in the surrounding parenchyma to grow again. For this reason, the development of techniques capable of providing high-resolution real-time images of tumor margins up to centimeters below the surface of a tissue is ideal for the diagnosis and treatment of tumors, as well as surgical guidance during brain tumor excision. A novel spectroscopic technique, non-resonant multiphoton photoacoustic spectroscopy (NMPPAS), is being developed with the capabilities of obtaining high-resolution subsurface chemical-based images of underlying tumors. This novel technique combines the strengths of multiphoton tissue spectroscopy and photoacoustic spectroscopy into a diagnostic methodology that will, ultimately, provide unparalleled chemical information and images to provide the state of sub-surface tissues. The NMPPAS technique employs near-infrared light (in the diagnostic window) to excite ultraviolet and/or visible light absorbing species deep below the tissue's surface. Once a multiphoton absorption event occurs, non-radiative relaxation processes generates a localized thermal expansion and subsequent acoustic wave that can be detected using a piezoelectric transducer. Since NMPPAS employs an acoustic detection modality, much deeper diagnoses can be performed than that is possible using current state of the art high-resolution chemical imaging techniques such as multiphoton fluorescence spectroscopy. NMPPAS was employed to differentiate between excised brain tumors (astrocytoma III) and healthy tissue with over 99% accuracy. NMPPAS spectral features showed evident differences between tumor and healthy tissues, and ratiometric analysis ensured that only a few wavelengths could be used for excitation instead of using numerous wavelength excitations to create spectra. This process would significantly reduce the analysis time while maintaining the same degree of accuracy. Tissue phantoms were fabricated in order to characterize the properties of NMPPAS. Scattering particles were doped into the phantoms to simulate their light scattering properties to real tissues. This allowed for better control over shape, size, reproducibility and doping in the sample while maintaining the light-tissue interaction properties of real tissue. To make NMPPAS viable for clinical applications, the technique was characterized to determine the spatial (lateral and longitudinal) resolution, depth of penetration and its ability to image in three-dimension through layers of tissue. Both resolutions were determined to be near-cellular level resolution (50-70 microm), obtained initially with the aid of the technique of multiphoton fluorescence, and later verified using NMPPAS imaging. Additionally, the maximum depth of penetration and detection was determined to be about 1.4cm, making the technique extremely suitable to margin tumors from underlying tissues in the brain. The capability of NMPPAS to detect and image layers that lie beneath other structures and blood vessels was also investigated. Three-dimensional images were obtained for the first time using NMPPAS. The images were obtained from different depths and structures were imaged through other layers of existing structures in the sample. This verified that NMPPAS was capable of detecting and imaging structures that lie embedded within the tissues. NMPPAS images of embedded structures were also obtained with the presence of hemoglobin, which is potentially the largest source of background in blood-perfused tissues, thus showing that the technique is capable of detecting and differentiating in blood-perfused samples.
"Doing School": A New Unit of Analysis for Schools Serving Marginalized Students
ERIC Educational Resources Information Center
Atkinson, Helen
2009-01-01
This study asserts a new unit of analysis for school reform that goes beyond the mental representations of individuals, beyond the isolated lesson, and beyond the confines of a school building. I argue that the special case of expanding time and space as a method of engagement for marginalized students requires that the unit of analysis change to…
Chatelain, Denis; Fuks, David; Farges, Olivier; Attencourt, Christophe; Pruvot, François René; Regimbeau, Jean-Marc
2013-12-01
To assess the accuracy of pathology reports on gallbladder specimens from patients operated on for incidental gallbladder carcinoma. Demographic data, details on pathological reports including gross and microscopic features section were recorded in 100 selected patients with incidental gallbladder carcinoma diagnosed from 2004 to 2007. Pathology reports had a conventional format in 93% of cases, without any standardization. Turnaround time ranged from 1 to 35 days. Frozen sections were performed in 20% of cases. The reports failed to give information on prognostic histological factors: exact tumour site (missing in 55% of cases), depth of tumour infiltration within the gallbladder wall (missing in 10%), surgical margins (missing in 40% for the cystic duct margin), tumour differentiation (missing in 28%), vascular invasion (missing in 52%) and perineural invasion (missing in 51%). Lymph node status could be assessed in 44% of cases. Distances between the tumour and the cystic duct and circumferential margins were not specified in 68% and 84% of cases. Only 29% of the reports clearly stated the pTNM stage in the conclusion section. The pT stage with margin status and tumour site was only mentioned in 30% of the reports. Pathology reports on gallbladder carcinoma from participating centres frequently lacked important information on key prognostic histological factors. Copyright © 2013 Editrice Gastroenterologica Italiana S.r.l. Published by Elsevier Ltd. All rights reserved.
Schaufele, Fred
2013-01-01
Förster resonance energy transfer (FRET) between fluorescent proteins (FPs) provides insights into the proximities and orientations of FPs as surrogates of the biochemical interactions and structures of the factors to which the FPs are genetically fused. As powerful as FRET methods are, technical issues have impeded their broad adoption in the biologic sciences. One hurdle to accurate and reproducible FRET microscopy measurement stems from variable fluorescence backgrounds both within a field and between different fields. Those variations introduce errors into the precise quantification of fluorescence levels on which the quantitative accuracy of FRET measurement is highly dependent. This measurement error is particularly problematic for screening campaigns since minimal well-to-well variation is necessary to faithfully identify wells with altered values. High content screening depends also upon maximizing the numbers of cells imaged, which is best achieved by low magnification high throughput microscopy. But, low magnification introduces flat-field correction issues that degrade the accuracy of background correction to cause poor reproducibility in FRET measurement. For live cell imaging, fluorescence of cell culture media in the fluorescence collection channels for the FPs commonly used for FRET analysis is a high source of background error. These signal-to-noise problems are compounded by the desire to express proteins at biologically meaningful levels that may only be marginally above the strong fluorescence background. Here, techniques are presented that correct for background fluctuations. Accurate calculation of FRET is realized even from images in which a non-flat background is 10-fold higher than the signal. PMID:23927839
Profitability analysis in the hospital industry.
Cleverley, W O
1978-01-01
Measures of marginal profit are derived for the two payment classes--cost payers and charge payers--that the hospital industry must consider in profitability analysis, i.e., prediction of the excess of revenue over expenses. Two indexes of profitability, use when payment mix is constant and when it is nonconstant, respectively, are derived from the two marginal profit measures, and one of them is shown to be a modification of the contribution margin, the conventional measure of profitability used in general industry. All three measures--the contribution margin and the two new indexes of profitability--are used to estimate changes in net income resulting from changes in patient volume with and without accompanying changes in payment mix. The conventional measure yields large overestimates of expected excess revenue. PMID:632101
The Ocean and Climate: Results from the TOPEX/POSEIDON Mission
NASA Technical Reports Server (NTRS)
Fu, L. -L.
1995-01-01
Since 1992, the TOPEX/POSEIDON satellite has been making altimetric sea surface observations with a sea level accuracy of 4.4 cm. This data can be used for studying regional and seasonal differences in sea level and for evaluating oceanic circulation models and tidal models. Longer term changes can also be studied, such as El Nino and overall sea level rising (although the latter is still within the margin of error).
Absolute Positioning Using The Earth’s Magnetic Anomaly Field
2016-09-15
many of these limitations. We present a navigation filter which uses the Earth’s magnetic anomaly field as a navigation signal to aid an inertial...navigation system (INS) in an aircraft. The filter utilizes highly-accurate optically pumped cesium (OPC) magnetometers to make scalar intensity...measurements of the Earth’s magnetic field and compare them to a map using a marginalized particle filter approach. The accuracy of these mea- surements allows
The Accuracy of Four Impression-making Techniques in Angulated Implants Based on Vertical Gap
Saboury, Abolfazl; Neshandar Asli, Hamid; Dalili Kajan, Zahra
2017-01-01
Statement of the Problem: Precision of the impression taken from implant positions significantly determines accurate fit of implant-supported prostheses. An imprecise impression may produce prosthesis misfit. Purpose: This study aimed to evaluate the accuracy of four impression-making techniques for angulated implants by stereomicroscope through measuring the vertical marginal gaps between the cemented metal framework and the implant analog. Materials and Method: A definitive cast with two 15° mesially angulated implants served as the standard reference for making all the impressions and later for accuracy evaluation. Four groups of five samples were evaluated: (1) closed-tray snap-fit transfer, (2) open-tray nonsplinted impression coping, (3) metal splinted impression coping, and (4) fabricated acrylic resin transfer cap. A gold-palladium framework was fabricated over the angulated implant abutments, the fit of which was used as reference. The gaps between the metal framework and the implant analogs were measured in sample groups. Corresponding means for each technique and the definitive cast were compared by using ANOVA and post hoc tests. Results: The mean marginal gap was 38.16±0µm in definitive cast, 89±19.74µm in group 1, 78.66±20.63µm in group 2, 54.16±24.29µm in group 3, and 55.83±18.30µm in group 4. ANOVA revealed significant differences between the definitive cast and groups 1 and 2, but not with groups 3 and 4 (p< 0.05). Conclusion: Vertical gap measurements showed that metal splinted impression coping and fabricated acrylic resin transfer cap techniques produced quite more accurate impressions than closed-tray snap-fit transfer and open-tray nonsplinted impression coping techniques do. The fabricated acrylic resin transfer cap technique seems to be a reliable impression-making method. PMID:29201973
DOE Office of Scientific and Technical Information (OSTI.GOV)
Sheng, Y; Li, T; Lee, W
Purpose: To provide benchmark for seminal vesicles (SVs) margin selection to account for intra-fractional motion; and to investigate the effectiveness of two motion surrogates in predicting intra-fractional SV underdosage. Methods: 9 prostate SBRT patients were studied; each has five pairs of pre-treatment and post-treatment cone-beam CTs (CBCTs). Each pair of CBCTs was registered based on fiducial markers in the prostate. To provide “ground truth” for coverage evaluation, all pre-treatment SVs were expanded with isotropic margin of 1,2,3,5 and 8mm, and their overlap with post-treatment SVs were used to quantify intra-fractional coverage. Two commonly used motion surrogates, the center-of-mass (COM) andmore » the border of contour (the most distal points in SI/AP/LR directions) were evaluated using Receiver-Operating Characteristic (ROC) analyses for predicting SV underdosage due to intra-fractional motion. Action threshold of determining underdosage for each surrogate was calculated by selecting the optimal balancing between sensitivity and specificity. For comparison, margin for each surrogate was also calculated based on traditional margin recipe. Results: 90% post-treatment SV coverage can be achieved in 47%, 82%, 91%, 98% and 98% fractions for 1,2,3,5 and 8mm margins. 3mm margin ensured the 90% intra-fractional SV coverage in 90% fractions when prostate was aligned. The ROC analysis indicated the AUC for COM and border were 0.88 and 0.72. The underdosage threshold was 2.9mm for COM and 4.1mm for border. The Van Herk’s margin recipe recommended 0.5, 0 and 1.8mm margin in LR, AP and SI direction based on COM and for border, the corresponding margin was 2.1, 4.5 and 3mm. Conclusion: 3mm isotropic margin is the minimum required to mitigate the intra-fractional SV motion when prostate is aligned. ROC analysis reveals that both COM and border are acceptable predictors for SV underdosage with 2.9mm and 4.1mm action threshold. Traditional margin calculation is less reliable for this application. This work is partially supported a master research grant from Varian Medical Systems.« less
ERIC Educational Resources Information Center
Ojeda, Lizette; Castillo, Linda G.; Rosales Meza, Rocío; Piña-Watson, Brandy
2014-01-01
This study examined how college persistence intentions and life satisfaction influenced by acculturation, enculturation, White marginalization, and Mexican American marginalization among 515 Mexican American college students. The utility of a path analysis model was supported. Enculturation positively predicted persistence and life satisfaction.…
MRI Evaluation of Resection Margins in Bone Tumour Surgery
Traore, Sidi Yaya; Lecouvet, Frédéric; Galant, Christine
2014-01-01
In 12 patients operated on for bone sarcoma resection, a postoperative magnetic resonance imaging of the resection specimens was obtained in order to assess the surgical margins. Margins were classified according to MRI in R0, R1, and R2 by three independent observers: a radiologist and two orthopaedic surgeons. Final margin evaluation (R0, R1, and R2) was assessed by a confirmed pathologist. Agreement for margin evaluation between the pathologist and the radiologist was perfect (κ = 1). Agreement between the pathologist and an experienced orthopaedic surgeon was very good while it was fair between the pathologist and a junior orthopaedic surgeon. MRI should be considered as a tool to give quick information about the adequacy of margins and to help the pathologist to focus on doubtful areas and to spare time in specimen analysis. But it may not replace the pathological evaluation that gives additional information about tumor necrosis. This study shows that MRI extemporaneous analysis of a resection specimen may be efficient in bone tumor oncologic surgery, if made by an experienced radiologist with perfect agreement with the pathologist. PMID:24976785
NASA Astrophysics Data System (ADS)
Cowie, Leanne; Kusznir, Nick; Horn, Brian
2014-05-01
Integrated quantitative analysis using deep seismic reflection data and gravity inversion have been applied to the S Angolan and SE Brazilian margins to determine OCT structure, COB location and magmatic type. Knowledge of these margin parameters are of critical importance for understanding rifted continental margin formation processes and in evaluating petroleum systems in deep-water frontier oil and gas exploration. The OCT structure, COB location and magmatic type of the S Angolan and SE Brazilian rifted continental margins are much debated; exhumed and serpentinised mantle have been reported at these margins. Gravity anomaly inversion, incorporating a lithosphere thermal gravity anomaly correction, has been used to determine Moho depth, crustal basement thickness and continental lithosphere thinning. Residual Depth Anomaly (RDA) analysis has been used to investigate OCT bathymetric anomalies with respect to expected oceanic bathymetries and subsidence analysis has been used to determine the distribution of continental lithosphere thinning. These techniques have been validated for profiles Lusigal 12 and ISE-01 on the Iberian margin. In addition a joint inversion technique using deep seismic reflection and gravity anomaly data has been applied to the ION-GXT BS1-575 SE Brazil and ION-GXT CS1-2400 S Angola deep seismic reflection lines. The joint inversion method solves for coincident seismic and gravity Moho in the time domain and calculates the lateral variations in crustal basement densities and velocities along the seismic profiles. Gravity inversion, RDA and subsidence analysis along the ION-GXT BS1-575 profile, which crosses the Sao Paulo Plateau and Florianopolis Ridge of the SE Brazilian margin, predict the COB to be located SE of the Florianopolis Ridge. Integrated quantitative analysis shows no evidence for exhumed mantle on this margin profile. The joint inversion technique predicts oceanic crustal thicknesses of between 7 and 8 km thickness with normal oceanic basement seismic velocities and densities. Beneath the Sao Paulo Plateau and Florianopolis Ridge, joint inversion predicts crustal basement thicknesses between 10-15km with high values of basement density and seismic velocities under the Sao Paulo Plateau which are interpreted as indicating a significant magmatic component within the crustal basement. The Sao Paulo Plateau and Florianopolis Ridge are separated by a thin region of crustal basement beneath the salt interpreted as a regional transtensional structure. Sediment corrected RDAs and gravity derived "synthetic" RDAs are of a similar magnitude on oceanic crust, implying negligible mantle dynamic topography. Gravity inversion, RDA and subsidence analysis along the S Angolan ION-GXT CS1-2400 profile suggests that exhumed mantle, corresponding to a magma poor margin, is absent..The thickness of earliest oceanic crust, derived from gravity and deep seismic reflection data, is approximately 7km consistent with the global average oceanic crustal thicknesses. The joint inversion predicts a small difference between oceanic and continental crustal basement density and seismic velocity, with the change in basement density and velocity corresponding to the COB independently determined from RDA and subsidence analysis. The difference between the sediment corrected RDA and that predicted from gravity inversion crustal thickness variation implies that this margin is experiencing approximately 500m of anomalous uplift attributed to mantle dynamic uplift.
Energy minimization in medical image analysis: Methodologies and applications.
Zhao, Feng; Xie, Xianghua
2016-02-01
Energy minimization is of particular interest in medical image analysis. In the past two decades, a variety of optimization schemes have been developed. In this paper, we present a comprehensive survey of the state-of-the-art optimization approaches. These algorithms are mainly classified into two categories: continuous method and discrete method. The former includes Newton-Raphson method, gradient descent method, conjugate gradient method, proximal gradient method, coordinate descent method, and genetic algorithm-based method, while the latter covers graph cuts method, belief propagation method, tree-reweighted message passing method, linear programming method, maximum margin learning method, simulated annealing method, and iterated conditional modes method. We also discuss the minimal surface method, primal-dual method, and the multi-objective optimization method. In addition, we review several comparative studies that evaluate the performance of different minimization techniques in terms of accuracy, efficiency, or complexity. These optimization techniques are widely used in many medical applications, for example, image segmentation, registration, reconstruction, motion tracking, and compressed sensing. We thus give an overview on those applications as well. Copyright © 2015 John Wiley & Sons, Ltd.
Hassan, A N; Beck, L R; Dister, S
1998-04-01
Remote sensing and geographic information system (GIS) technologies were used to discriminate between 130 villages, in the Nile Delta, at high and low risk for filariasis, as defined by microfilarial prevalence. Landsat Thematic Mapper (TM) data were digitally processed to generate a map of landcover as well as spectral indices such as NDVI and moisture index. A Tasseled Cap transformation was also carried out on the TM data which produced three more indices: brightness, greenness and wetness. GIS functions were used to extract information on landcover and spectral indices within one km buffers around the study villages. The relationship between satellite data and prevalence was investigated using discriminant analysis. The analysis indicated that the most important landscape elements associated with prevalence were water and marginal vegetation, while wetness and moisture index were the most important indices. Discriminant functions generated for these variables were able to correctly predict 80% and 74% of high and low prevalence villages, respectively, with an overall accuracy of 77%. The present approach provides a promising tool for regional filariasis surveillance and helps direct control efforts.
Fabrication and properties of multilayer structures
NASA Astrophysics Data System (ADS)
Tiller, W. A.
1983-09-01
The synthesis of SiC films and Pd2Si films via single source and dual source sputtering, respectively, has been experimentally investigated while the reactive sputter deposition of SiO sub x films has been theoretically analyzed. The SiO sub x film data requires a mobile precursor adsorption process to be operative for the oxygen and an oxygen sticking coefficient of between 1.56 x 10 to the minus 3rd power and 4.17 x 10 to the minus 3rd power. An analysis of in-situ electrical diagnostics of the films via a non-contact technique shows the method to be of marginal accuracy for the example selected. An important new formulation of the stress and elastic constant tensors in the vicinity of interfaces has been developed and applied to the simple example of adsorbed layer/substrate interactions via a parametric analysis. Atomic modeling of the SiO system yields peroxide bond formation for oxygen-rich (100) alpha-cristobalite surfaces. Radial distribution function and angular distribution function data have been calculated for bulk alpha-quartz and bulk alpha-cristobalite in good agreement with experiment.
Study of a safety margin system for powered-lift STOL aircraft
NASA Technical Reports Server (NTRS)
Heffley, R. K.; Jewell, W. F.
1978-01-01
A study was conducted to explore the feasibility of a safety margin system for powered-lift aircraft which require a backside piloting technique. The objective of the safety margin system was to present multiple safety margin criteria as a single variable which could be tracked manually or automatically and which could be monitored for the purpose of deriving safety margin status. The study involved a pilot-in-the-loop analysis of several safety margin system concepts and a simulation experiment to evaluate those concepts which showed promise of providing a good solution. A system was ultimately configured which offered reasonable compromises in controllability, status information content, and the ability to regulate the safety margin at some expense of the allowable low speed flight path envelope.
Sfoungaristos, S; Kavouras, A; Kanatas, P; Polimeros, N; Perimenis, P
2011-01-01
To compare the predictive ability of primary and secondary Gleason pattern for positive surgical margins in patients with clinically localized prostate cancer and a preoperative Gleason score ≤ 6. A retrospective analysis of the medical records of patients undergone a radical prostatectomy between January 2005 and October 2010 was conducted. Patients' age, prostate volume, preoperative PSA, biopsy Gleason score, the 1st and 2nd Gleason pattern were entered a univariate and multivariate analysis. The 1st and 2nd pattern were tested for their ability to predict positive surgical margins using receiver operating characteristic curves. Positive surgical margins were noticed in 56 cases (38.1%) out of 147 studied patients. The 2nd pattern was significantly greater in those with positive surgical margins while the 1st pattern was not significantly different between the 2 groups of patients. ROC analysis revealed that area under the curve was 0.53 (p=0.538) for the 1st pattern and 0.60 (p=0.048) for the 2nd pattern. Concerning the cases with PSA <10 ng/ml, it was also found that only the 2nd pattern had a predictive ability (p=0.050). When multiple logistic regression analysis was conducted it was found that the 2nd pattern was the only independent predictor. The second Gleason pattern was found to be of higher value than the 1st one for the prediction of positive surgical margins in patients with preoperative Gleason score ≤ 6 and this should be considered especially when a neurovascular bundle sparing radical prostatectomy is planned, in order not to harm the oncological outcome.
NASA Astrophysics Data System (ADS)
Walke, N.; Obi Reddy, G. P.; Maji, A. K.; Thayalan, S.
2012-04-01
In this study an attempt was made to characterize the soils of the Ringanbodi watershed, Nagpur district, Maharashtra, Central India, for soil-suitability evaluation for cotton using geographic information system (GIS)-based multicriteria overlay analysis techniques. The study shows that 8 soil series and 16 soil series associations in the study area and soils were classified into three orders, i.e., Entisol, Inceptisol, and Vertisol. The analysis reveals that the soil associations E-F, F-G, G-H, and H-G are "moderately suitable" (S2), D-E are "marginally to moderately suitable," and C-D are marginally (S3) suitable. However, soils B-C are "not suitable" to "marginally suitable" (N2-S3) and A-B are "unsuitable" (N2) for cultivation of cotton. The area analysis shows that for a cotton crop an area about 966.7 ha (49.1%) of TGA is moderately suitable and classified as S2. An area about 469.9 ha (23.8%) of TGA is marginal to moderately suitable (S3-S2). The marginally suitable soils for cotton are classified as S3 and cover an area about 35.2 ha (1.8%) of TGA. However, a 172.3 ha (8.7%) area is not suitable (N2) to marginally suitable (S3) and a 326.9 (16.6%) area is not suitable (N2) for cotton because of uncorrectable factors like soil depth, slope, etc. The study demonstrated that GIS-based multicriteria overlay analysis of soil thematic parameters will be of immense help in soil-suitability evaluation for cotton.
Cervical and Incisal Marginal Discrepancy in Ceramic Laminate Veneering Materials: A SEM Analysis
Ranganathan, Hemalatha; Ganapathy, Dhanraj M.; Jain, Ashish R.
2017-01-01
Context: Marginal discrepancy influenced by the choice of processing material used for the ceramic laminate veneers needs to be explored further for better clinical application. Aims: This study aimed to evaluate the amount of cervical and incisal marginal discrepancy associated with different ceramic laminate veneering materials. Settings and Design: This was an experimental, single-blinded, in vitro trial. Subjects and Methods: Ten central incisors were prepared for laminate veneers with 2 mm uniform reduction and heavy chamfer finish line. Ceramic laminate veneers fabricated over the prepared teeth using four different processing materials were categorized into four groups as Group I - aluminous porcelain veneers, Group II - lithium disilicate ceramic veneers, Group III - lithium disilicate-leucite-based veneers, Group IV - zirconia-based ceramic veneers. The cervical and incisal marginal discrepancy was measured using a scanning electron microscope. Statistical Analysis Used: ANOVA and post hoc Tukey honest significant difference (HSD) tests were used for statistical analysis. Results: The cervical and incisal marginal discrepancy for four groups was Group I - 114.6 ± 4.3 μm, 132.5 ± 6.5 μm, Group II - 86.1 ± 6.3 μm, 105.4 ± 5.3 μm, Group III - 71.4 ± 4.4 μm, 91.3 ± 4.7 μm, and Group IV - 123.1 ± 4.1 μm, 142.0 ± 5.4 μm. ANOVA and post hoc Tukey HSD tests observed a statistically significant difference between the four test specimens with regard to cervical marginal discrepancy. The cervical and incisal marginal discrepancy scored F = 243.408, P < 0.001 and F = 180.844, P < 0.001, respectively. Conclusion: This study concluded veneers fabricated using leucite reinforced lithium disilicate exhibited the least marginal discrepancy followed by lithium disilicate ceramic, aluminous porcelain, and zirconia-based ceramics. The marginal discrepancy was more in the incisal region than in the cervical region in all the groups. PMID:28839415
Thieler, E. Robert; Danforth, William W.
1994-01-01
A new, state-of-the-art method for mapping historical shorelines from maps and aerial photographs, the Digital Shoreline Mapping System (DSMS), has been developed. The DSMS is a freely available, public domain software package that meets the cartographic and photogrammetric requirements of precise coastal mapping, and provides a means to quantify and analyze different sources of error in the mapping process. The DSMS is also capable of resolving imperfections in aerial photography that commonly are assumed to be nonexistent. The DSMS utilizes commonly available computer hardware and software, and permits the entire shoreline mapping process to be executed rapidly by a single person in a small lab. The DSMS generates output shoreline position data that are compatible with a variety of Geographic Information Systems (GIS). A second suite of programs, the Digital Shoreline Analysis System (DSAS) has been developed to calculate shoreline rates-of-change from a series of shoreline data residing in a GIS. Four rate-of-change statistics are calculated simultaneously (end-point rate, average of rates, linear regression and jackknife) at a user-specified interval along the shoreline using a measurement baseline approach. An example of DSMS and DSAS application using historical maps and air photos of Punta Uvero, Puerto Rico provides a basis for assessing the errors associated with the source materials as well as the accuracy of computed shoreline positions and erosion rates. The maps and photos used here represent a common situation in shoreline mapping: marginal-quality source materials. The maps and photos are near the usable upper limit of scale and accuracy, yet the shoreline positions are still accurate ±9.25 m when all sources of error are considered. This level of accuracy yields a resolution of ±0.51 m/yr for shoreline rates-of-change in this example, and is sufficient to identify the short-term trend (36 years) of shoreline change in the study area.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Paffenhofer, G.A.; Verity, P.G.
1995-12-31
Three fates potentially consume primary production occurring on ocean margins: portions can be oxidized within the water column, portions can sediment to shelf/slope depots, and portions can be exported to the interior ocean. Zooplankton mediate all three of these processes and thus can alter the pathway and residence time of particulate organic carbon, depending on the size structure and composition of the zooplankton (and phytoplankton). To achieve the long-term goal of quantifying the role of proto- and metazooplankton in removing newly formed POC (primary production), the authors must accomplish two major component objectives: (a) determine plankton carbon biomass at relevantmore » temporal and spatial scales; and (b) measure zooplankton carbon consumption rates and (for metazoan zooplankton) fecal pellet production. These measurements will specify the importance of different zooplankton groups as consumers and transformers of phytoplankton carbon. During Phase 1, they concentrated on methodological and technological developments prerequisite to an organized field program. Specifically, they proposed to develop and test an optical zooplankton counter, and to fully enhance the color image analysis system. In addition, they proposed to evaluate a solid-phase enzyme-linked immunospot assay to quantify predation by metazoan zooplankton on protozoans; and to improve methodology to determine ingestion and growth rates of salps, and accompanying pellet production rates, under conditions which very closely resemble their environment. The image analyzer data provide insights on basic ecosystem parameters relevant to carbon flux from the continental ocean to the deep ocean. Together these approaches provide a powerful set of tools to probe food web relationships in greater detail, to increase the accuracy and speed of carbon biomass and rate measurements, and to enhance data collection and analysis.« less
Koizumi, Atsushi; Narita, Shintaro; Nara, Taketoshi; Takayama, Koichiro; Kanda, Sohei; Numakura, Kazuyuki; Tsuruta, Hiroshi; Maeno, Atsushi; Huang, Mingguo; Saito, Mitsuru; Inoue, Takamitsu; Tsuchiya, Norihiko; Satoh, Shigeru; Nanjo, Hiroshi; Habuchi, Tomonori
2018-06-19
To evaluate the positive surgical margin rates and locations in radical prostatectomy among three surgical approaches, including open radical prostatectomy, laparoscopic radical prostatectomy and robot-assisted radical prostatectomy. We retrospectively reviewed clinical outcomes at our institution of 450 patients who received radical prostatectomy. Multiple surgeons were involved in the three approaches, and a single pathologist conducted the histopathological diagnoses. Positive surgical margin rates and locations among the three approaches were statistically assessed, and the risk factors of positive surgical margin were analyzed. This study included 127, 136 and 187 patients in the open radical prostatectomy, laparoscopic radical prostatectomy and robot-assisted radical prostatectomy groups, respectively. The positive surgical margin rates were 27.6% (open radical prostatectomy), 18.4% (laparoscopic radical prostatectomy) and 13.4% (robot-assisted radical prostatectomy). In propensity score-matched analyses, the positive surgical margin rate in the robot-assisted radical prostatectomy was significantly lower than that in the open radical prostatectomy, whereas there was no significant difference in the positive surgical margin rates between robot-assisted radical prostatectomy and laparoscopic radical prostatectomy. In the multivariable analysis, PSA level at diagnosis and surgical approach (open radical prostatectomy vs robot-assisted radical prostatectomy) were independent risk factors for positive surgical margin. The apex was the most common location of positive surgical margin in the open radical prostatectomy and laparoscopic radical prostatectomy groups, whereas the bladder neck was the most common location in the robot-assisted radical prostatectomy group. The significant difference of positive surgical margin locations continued after the propensity score adjustment. Robot-assisted radical prostatectomy may potentially achieve the lowest positive surgical margin rate among three surgical approaches. The bladder neck was the most common location of positive surgical margin in robot-assisted radical prostatectomy and apex in open radical prostatectomy and laparoscopic radical prostatectomy. Although robot-assisted radical prostatectomy may contribute to the reduction of positive surgical margin, dissection of the bladder neck requires careful attention to avoid positive surgical margins.
Excess Capacity in China’s Power Systems: A Regional Analysis
DOE Office of Scientific and Technical Information (OSTI.GOV)
Lin, Jiang; Liu, Xu; Karl, Fredrich
2016-11-01
This paper examines China’s regional electricity grids using a reliability perspective, which is commonly measured in terms of a reserve margin. Our analysis shows that at the end of 2014, the average reserve margin for China as a whole was roughly 28%, almost twice as high as a typical planning reserve margin in the U.S. However, this national average masks huge variations in reserve margins across major regional power grid areas: the northeastern region has the highest reserve margin of over 60%, followed by the northwestern region at 49%, and the southern grid area at 35%. In this analysis, wemore » also examined future reserve margins for regional electricity grids in China under two scenarios: 1) a low scenario of national annual electricity consumption growth rates of 1.5% between 2015 and 2020 and 1.0% between 2020 and 2025, and 2) a high scenario of annual average growth rates of 3.0% and 2.0%, respectively. Both scenarios suggest that the northeastern, northwestern, and southern regions have significant excess generation capacity, and that this excess capacity situation will continue over the next decade without regulatory intervention. The northern and central regions could have sufficient generation capacity to 2020, but may require additional resources in a higher growth scenario. The eastern region requires new resources by 2020 in both scenarios.« less
Assessing Predictive Properties of Genome-Wide Selection in Soybeans
Xavier, Alencar; Muir, William M.; Rainey, Katy Martin
2016-01-01
Many economically important traits in plant breeding have low heritability or are difficult to measure. For these traits, genomic selection has attractive features and may boost genetic gains. Our goal was to evaluate alternative scenarios to implement genomic selection for yield components in soybean (Glycine max L. merr). We used a nested association panel with cross validation to evaluate the impacts of training population size, genotyping density, and prediction model on the accuracy of genomic prediction. Our results indicate that training population size was the factor most relevant to improvement in genome-wide prediction, with greatest improvement observed in training sets up to 2000 individuals. We discuss assumptions that influence the choice of the prediction model. Although alternative models had minor impacts on prediction accuracy, the most robust prediction model was the combination of reproducing kernel Hilbert space regression and BayesB. Higher genotyping density marginally improved accuracy. Our study finds that breeding programs seeking efficient genomic selection in soybeans would best allocate resources by investing in a representative training set. PMID:27317786
Factors affecting surgical margin recurrence after hepatectomy for colorectal liver metastases.
Akyuz, Muhammet; Aucejo, Federico; Quintini, Cristiano; Miller, Charles; Fung, John; Berber, Eren
2016-06-01
Hepatic recurrence after resection of colorectal liver metastasis (CLM) occurs in 50% of patients during follow-up, with 2.8% to 13.9% presenting with surgical margin recurrence (SMR). The aim of this study is to analyze factors that related to SMR in patients with CLM undergoing hepatectomy. Demographics, clinical and survival data of patients who underwent hepatectomy were identified from a prospectively maintained, institutional review board (IRB)-approved database between 2000 and 2012. Statistical analysis was performed using univariate Kaplan Meier and Cox proportional hazard model. There were 85 female and 121 male patients who underwent liver resection for CLM. An R0 resection was performed in 157 (76%) patients and R1 resection in 49. SMR was detected in 32 patients (15.5%) followed up for a median of 29 months (range, 3-121 months). A half of these patients had undergone R1 (n=16) and another half R0 resection (n=16). Tumor size, preoperative carcinoembryonic antigen (CEA) level and margin status were associated with SMR on univariate analysis. On multivariate analysis, a positive surgical margin was the only independent predictor of SMR. The receipt of adjuvant chemotherapy did not affect margin recurrence. SMR was an independent risk factor associated with worse disease-free (DFS) and overall survival (OS). This study shows that SMR, which can be detected in up to 15.5% of patients after liver resection for CLM, adversely affects DFS and OS. The fact that a positive surgical margin was the only predictive factor for SMR in these patients underscores the importance of achieving negative margins during hepatectomy.
Ozawa, Michael G; Bhaduri, Aparna; Chisholm, Karen M; Baker, Steven A; Ma, Lisa; Zehnder, James L; Luna-Fineman, Sandra; Link, Michael P; Merker, Jason D; Arber, Daniel A; Ohgami, Robert S
2016-10-01
Pediatric-type follicular lymphoma and pediatric marginal zone lymphoma are two of the rarest B-cell lymphomas. These lymphomas occur predominantly in the pediatric population and show features distinct from their more common counterparts in adults: adult-type follicular lymphoma and adult-type nodal marginal zone lymphoma. Here we report a detailed whole-exome deep sequencing analysis of a cohort of pediatric-type follicular lymphomas and pediatric marginal zone lymphomas. This analysis revealed a recurrent somatic variant encoding p.Lys66Arg in the transcription factor interferon regulatory factor 8 (IRF8) in 3 of 6 cases (50%) of pediatric-type follicular lymphoma. This specific point mutation was not detected in pediatric marginal zone lymphoma or in adult-type follicular lymphoma. Additional somatic point mutations in pediatric-type follicular lymphoma were observed in genes involved in transcription, intracellular signaling, and cell proliferation. In pediatric marginal zone lymphoma, no recurrent mutation was identified; however, somatic point mutations were observed in genes involved in cellular adhesion, cytokine regulatory elements, and cellular proliferation. A somatic variant in AMOTL1, a recurrently mutated gene in splenic marginal zone lymphoma, was also identified in a case of pediatric marginal zone lymphoma. The overall non-synonymous mutational burden was low in both pediatric-type follicular lymphoma and pediatric marginal zone lymphoma (4.6 mutations per exome). Altogether, these findings support a distinctive genetic basis for pediatric-type follicular lymphoma and pediatric marginal zone lymphoma when compared with adult subtypes and to one another. Moreover, identification of a recurrent point mutation in IRF8 provides insight into a potential driver mutation in the pathogenesis of pediatric-type follicular lymphoma with implications for novel diagnostic or therapeutic strategies.
Ozawa, Michael G; Bhaduri, Aparna; Chisholm, Karen M; Baker, Steven A; Ma, Lisa; Zehnder, James L; Luna-Fineman, Sandra; Link, Michael P; Merker, Jason D; Arber, Daniel A; Ohgami, Robert S
2016-01-01
Pediatric-type follicular lymphoma and pediatric marginal zone lymphoma are two of the rarest B-cell lymphomas. These lymphomas occur predominantly in the pediatric population and show features distinct from their more common counterparts in adults: adult-type follicular lymphoma and adult-type nodal marginal zone lymphoma. Here we report a detailed whole-exome deep sequencing analysis of a cohort of pediatric-type follicular lymphomas and pediatric marginal zone lymphomas. This analysis revealed a recurrent somatic variant encoding p.Lys66Arg in the transcription factor interferon regulatory factor 8 (IRF8) in 3 of 6 cases (50%) of pediatric-type follicular lymphoma. This specific point mutation was not detected in pediatric marginal zone lymphoma or in adult-type follicular lymphoma. Additional somatic point mutations in pediatric-type follicular lymphoma were observed in genes involved in transcription, intracellular signaling, and cell proliferation. In pediatric marginal zone lymphoma, no recurrent mutation was identified; however, somatic point mutations were observed in genes involved in cellular adhesion, cytokine regulatory elements, and cellular proliferation. A somatic variant in AMOTL1, a recurrently mutated gene in splenic marginal zone lymphoma, was also identified in a case of pediatric marginal zone lymphoma. The overall non-synonymous mutational burden was low in both pediatric-type follicular lymphoma and pediatric marginal zone lymphoma (4.6 mutations per exome). Altogether, these findings support a distinctive genetic basis for pediatric-type follicular lymphoma and pediatric marginal zone lymphoma when compared with adult subtypes and to one another. Moreover, identification of a recurrent point mutation in IRF8 provides insight into a potential driver mutation in the pathogenesis of pediatric-type follicular lymphoma with implications for novel diagnostic or therapeutic strategies. PMID:27338637
Marginal and Random Intercepts Models for Longitudinal Binary Data with Examples from Criminology
ERIC Educational Resources Information Center
Long, Jeffrey D.; Loeber, Rolf; Farrington, David P.
2009-01-01
Two models for the analysis of longitudinal binary data are discussed: the marginal model and the random intercepts model. In contrast to the linear mixed model (LMM), the two models for binary data are not subsumed under a single hierarchical model. The marginal model provides group-level information whereas the random intercepts model provides…
Marginal lands for biocontrol and ecosystem services: Where to enhance and what do we put there?
USDA-ARS?s Scientific Manuscript database
Analysis of the Coastal Plain of Georgia, USA identified over 300,000 hectares of marginal land. There is a potential to grow other non-commodity native plants in marginal areas that have the potential to improve the diversity of the landscape and promote ecosystem services. Bioenergy feedstocks are...
ERIC Educational Resources Information Center
Purcell-Gates, Victoria
2014-01-01
This analysis examines the nexus of marginalization and education, particularly the literacy potential and achievement of young children from socially and politically marginalized communities. Drawing on data from a study of literacy practice among Nicaraguan immigrants in Costa Rica and the schooling of the Nicaraguan children in Costa Rican…
Haghi, Hamidreza Rajati; Shiehzadeh, Masoud; Nakhaei, Mohammadreza; Ahrary, Fatemeh; Sabzevari, Saeid
2017-01-01
Introduction: A dental impression is a negative imprint of an oral structure that can be used to produce a positive cast of a patient's teeth as a permanent record. The accuracy of the impression affects the accuracy of the cast, and a precise impression is needed in order to create prosthesis with optimal fitting. Minimization of misfit is an important aim in prosthesis science and dental implants. The aim of this study was to evaluate the effects of the materials and techniques used to take an impression on the vertical misfit of implant-supported, screw-retained, three-unit bridges. Materials and Methods: The principal model used was an acrylic block with two ITI implants. A 1.5-mm abutment was attached to fixtures with torque of 25 N.cm. A base-metal framework was built on the abutment in the acrylic block. The abutments of the acrylic model were unscrewed and fixture-level impressions were made. The impression techniques included open/closed-tray techniques and the impression materials were polyether and polyvinyl siloxane. Forty acrylic custom trays were built for each impression. The marginal gap in the framework at three points (buccal, lingual, and distal) was measured using an optical microscope with ×250. Results: It is demonstrated that in all 360 evaluated samples, the mean vertical misfit in polyether samples of molar and premolar teeth was significantly lower than in polyvinyl siloxane (P < 0.001 and P = 0.017, respectively) in all three locations of the molar and lingual premolar examined (buccal, lingual, and distal), the mean vertical misfit of the polyether samples was significantly lower than those of polyvinyl siloxane (P < 0.01). On the other hand, although the mean vertical misfit using the open-tray technique in the molar teeth was significantly lower than with the closed-tray method (P = 0.002), no statistical difference was seen between the open-tray and closed-tray technique in general (P = 0.87). Conclusion: Within the limitations of this study, the following conclusions can be drawn: The impression method had no effect on marginal discrepancy of 3-unit screw retained fixed partial dentures. A higher marginal accuracy was obtained using polyether impression material compared to polyvinyl siloxane. PMID:28216844
In vitro evaluation of the marginal integrity of CAD/CAM interim crowns.
Kelvin Khng, Kwang Yong; Ettinger, Ronald L; Armstrong, Steven R; Lindquist, Terry; Gratton, David G; Qian, Fang
2016-05-01
The accuracy of interim crowns made with computer-aided design and computer-aided manufacturing (CAD/CAM) systems has not been well investigated. The purpose of this in vitro study was to evaluate the marginal integrity of interim crowns made by CAD/CAM compared with that of conventional polymethylmethacrylate (PMMA) crowns. A dentoform mandibular left second premolar was prepared for a ceramic crown and scanned for the fabrication of 60 stereolithical resin dies, half of which were scanned to fabricate 15 Telio CAD-CEREC and 15 Paradigm MZ100-E4D-E4D crowns. Fifteen Caulk and 15 Jet interim crowns were made on the remaining resin dies. All crowns were cemented with Tempgrip under a 17.8-N load, thermocycled for 1000 cycles, placed in 0.5% acid fuschin for 24 hours, and embedded in epoxy resin before sectioning from the mid-buccal to mid-lingual surface. The marginal discrepancy was measured using a traveling microscope, and dye penetration was measured as a percentage of the overall length under the crown. The mean vertical marginal discrepancy of the conventionally made interim crowns was greater than for the CAD/CAM crowns (P=.006), while no difference was found for the horizontal component (P=.276). The mean vertical marginal discrepancy at the facial surface of the Caulk crowns was significantly greater than that of the other 3 types of interim crowns (P<.001). At the facial margin, the mean horizontal component of the Telio crowns was significantly larger than that of the other 3 types, with no difference at the lingual margins (P=.150). The mean percentage dye penetration for the Paradigm MZ100-E4D crowns was significantly greater and for Jet crowns significantly smaller than for the other 3 crowns (P<.001). However, the mean percentage dye penetration was significantly correlated with the vertical and horizontal marginal discrepancies of the Jet interim crowns at the facial surface and with the horizontal marginal discrepancies of the Caulk interim crowns at the lingual surface (P<.01 in each instance). A significantly smaller vertical marginal discrepancy was found with the interim crowns fabricated by CAD/CAM as compared with PMMA crowns; however, this difference was not observed for the horizontal component. The percentage dye penetration was correlated with vertical and horizontal discrepancies at the facial surface for the Jet interim crowns and with horizontal discrepancies at the lingual surface for the Caulk interim crowns. Copyright © 2016 Editorial Council for the Journal of Prosthetic Dentistry. Published by Elsevier Inc. All rights reserved.
Witjes, Max J H; Schepers, Rutger H; Kraeima, Joep
2018-04-01
This review describes the advances in 3D virtual planning for mandibular and maxillary reconstruction surgical defects with full prosthetic rehabilitation. The primary purpose is to provide an overview of various techniques that apply 3D technology safely in primary and secondary reconstructive cases of patients suffering from head and neck cancer. Methods have been developed to overcome the problem of control over the margin during surgery while the crucial decision with regard to resection margin and planning of osteotomies were predetermined by virtual planning. The unlimited possibilities of designing patient-specific implants can result in creative uniquely applied solutions for single cases but should be applied wisely with knowledge of biomechanical engineering principles. The high surgical accuracy of an executed 3D virtual plan provides tumor margin control during ablative surgery and the possibility of planned combined use of osseus free flaps and dental implants in the reconstruction in one surgical procedure. A thorough understanding of the effects of radiotherapy on the reconstruction, soft tissue management, and prosthetic rehabilitation is imperative in individual cases when deciding to use dental implants in patients who received radiotherapy.
Tozaki, Mitsuhiro; Saito, Masahiro; Benson, John; Fan, Liexiang; Isobe, Sachiko
2013-12-01
This study compared the diagnostic performance of two shear wave speed measurement techniques in 81 patients with 83 solid breast lesions. Virtual Touch Quantification, which provides single-point shear wave speed measurement capability (SP-SWS), was compared with Virtual Touch IQ, a new 2-D shear wave imaging technique with multi-point shear wave speed measurement capability (2D-SWS). With SP-SWS, shear wave velocity was measured within the lesion ("internal" value) and the marginal areas ("marginal" value). With 2D-SWS, the highest velocity was measured. The marginal values obtained with the SP-SWS and 2D-SWS methods were significantly higher for malignant lesions and benign lesions, respectively (p < 0.0001). Sensitivity, specificity and accuracy were 86% (36/42), 90% (37/41) and 88% (73/83), respectively, for SP-SWS, and 88% (37/42), 93% (38/41) and 90% (75/83), respectively, for 2D-SWS. It is concluded that 2D-SWS is a useful diagnostic tool for differentiating malignant from benign solid breast masses. Copyright © 2013 World Federation for Ultrasound in Medicine & Biology. Published by Elsevier Inc. All rights reserved.
Negative Stress Margins - Are They Real?
NASA Technical Reports Server (NTRS)
Raju, Ivatury S.; Lee, Darlene S.; Mohaghegh, Michael
2011-01-01
Advances in modeling and simulation, new finite element software, modeling engines and powerful computers are providing opportunities to interrogate designs in a very different manner and in a more detailed approach than ever before. Margins of safety are also often evaluated using local stresses for various design concepts and design parameters quickly once analysis models are defined and developed. This paper suggests that not all the negative margins of safety evaluated are real. The structural areas where negative margins are frequently encountered are often near stress concentrations, point loads and load discontinuities, near locations of stress singularities, in areas having large gradients but with insufficient mesh density, in areas with modeling issues and modeling errors, and in areas with connections and interfaces, in two-dimensional (2D) and three-dimensional (3D) transitions, bolts and bolt modeling, and boundary conditions. Now, more than ever, structural analysts need to examine and interrogate their analysis results and perform basic sanity checks to determine if these negative margins are real.
The clinical evaluation of the CADence device in the acoustic detection of coronary artery disease.
Thomas, Joseph L; Ridner, Michael; Cole, Jason H; Chambers, Jeffrey W; Bokhari, Sabahat; Yannopoulos, Demetris; Kern, Morton; Wilson, Robert F; Budoff, Matthew J
2018-06-23
The noninvasive detection of turbulent coronary flow may enable diagnosis of significant coronary artery disease (CAD) using novel sensor and analytic technology. Eligible patients (n = 1013) with chest pain and CAD risk factors undergoing nuclear stress testing were studied using the CADence (AUM Cardiovascular Inc., Northfield MN) acoustic detection (AD) system. The trial was designed to demonstrate non-inferiority of AD for diagnostic accuracy in detecting significant CAD as compared to an objective performance criteria (sensitivity 83% and specificity 80%, with 15% non-inferiority margins) for nuclear stress testing. AD analysis was blinded to clinical, core lab-adjudicated angiographic, and nuclear data. The presence of significant CAD was determined by computed tomographic (CCTA) or invasive angiography. A total of 1013 subjects without prior coronary revascularization or Q-wave myocardial infarction were enrolled. Primary analysis was performed on subjects with complete angiographic and AD data (n = 763) including 111 subjects (15%) with severe CAD based on CCTA (n = 34) and invasive angiography (n = 77). The sensitivity and specificity of AD were 78% (p = 0.012 for non-inferiority) and 35% (p < 0.001 for failure to demonstrate non-inferiority), respectively. AD results had a high 91% negative predictive value for the presence of significant CAD. AD testing failed to demonstrate non-inferior diagnostic accuracy as compared to the historical performance of a nuclear stress OPC due to low specificity. AD sensitivity was non-inferior in detecting significant CAD with a high negative predictive value supporting a potential value in excluding CAD.
Singh, Minerva; Evans, Damian; Tan, Boun Suy; Nin, Chan Samean
2015-01-01
At present, there is very limited information on the ecology, distribution, and structure of Cambodia's tree species to warrant suitable conservation measures. The aim of this study was to assess various methods of analysis of aerial imagery for characterization of the forest mensuration variables (i.e., tree height and crown width) of selected tree species found in the forested region around the temples of Angkor Thom, Cambodia. Object-based image analysis (OBIA) was used (using multiresolution segmentation) to delineate individual tree crowns from very-high-resolution (VHR) aerial imagery and light detection and ranging (LiDAR) data. Crown width and tree height values that were extracted using multiresolution segmentation showed a high level of congruence with field-measured values of the trees (Spearman's rho 0.782 and 0.589, respectively). Individual tree crowns that were delineated from aerial imagery using multiresolution segmentation had a high level of segmentation accuracy (69.22%), whereas tree crowns delineated using watershed segmentation underestimated the field-measured tree crown widths. Both spectral angle mapper (SAM) and maximum likelihood (ML) classifications were applied to the aerial imagery for mapping of selected tree species. The latter was found to be more suitable for tree species classification. Individual tree species were identified with high accuracy. Inclusion of textural information further improved species identification, albeit marginally. Our findings suggest that VHR aerial imagery, in conjunction with OBIA-based segmentation methods (such as multiresolution segmentation) and supervised classification techniques are useful for tree species mapping and for studies of the forest mensuration variables.
Singh, Minerva; Evans, Damian; Tan, Boun Suy; Nin, Chan Samean
2015-01-01
At present, there is very limited information on the ecology, distribution, and structure of Cambodia’s tree species to warrant suitable conservation measures. The aim of this study was to assess various methods of analysis of aerial imagery for characterization of the forest mensuration variables (i.e., tree height and crown width) of selected tree species found in the forested region around the temples of Angkor Thom, Cambodia. Object-based image analysis (OBIA) was used (using multiresolution segmentation) to delineate individual tree crowns from very-high-resolution (VHR) aerial imagery and light detection and ranging (LiDAR) data. Crown width and tree height values that were extracted using multiresolution segmentation showed a high level of congruence with field-measured values of the trees (Spearman’s rho 0.782 and 0.589, respectively). Individual tree crowns that were delineated from aerial imagery using multiresolution segmentation had a high level of segmentation accuracy (69.22%), whereas tree crowns delineated using watershed segmentation underestimated the field-measured tree crown widths. Both spectral angle mapper (SAM) and maximum likelihood (ML) classifications were applied to the aerial imagery for mapping of selected tree species. The latter was found to be more suitable for tree species classification. Individual tree species were identified with high accuracy. Inclusion of textural information further improved species identification, albeit marginally. Our findings suggest that VHR aerial imagery, in conjunction with OBIA-based segmentation methods (such as multiresolution segmentation) and supervised classification techniques are useful for tree species mapping and for studies of the forest mensuration variables. PMID:25902148
Hartl, Caroline; Frank, Kilian; Amenitsch, Heinz; Fischer, Stefan; Liedl, Tim; Nickel, Bert
2018-04-11
DNA origami objects allow for accurate positioning of guest molecules in three dimensions. Validation and understanding of design strategies for particle attachment as well as analysis of specific particle arrangements are desirable. Small-angle X-ray scattering (SAXS) is suited to probe distances of nano-objects with subnanometer resolution at physiologically relevant conditions including pH and salt and at varying temperatures. Here, we show that the pair density distribution function (PDDF) obtained from an indirect Fourier transform of SAXS intensities in a model-free way allows to investigate prototypical DNA origami-mediated gold nanoparticle (AuNP) assemblies. We analyze the structure of three AuNP-dimers on a DNA origami block, an AuNP trimer constituted by those dimers, and a helical arrangement of nine AuNPs on a DNA origami cylinder. For the dimers, we compare the model-free PDDF and explicit modeling of the SAXS intensity data by superposition of scattering intensities of the scattering objects. The PDDF of the trimer is verified to be a superposition of its dimeric contributions, that is, here AuNP-DNA origami assemblies were used as test boards underlining the validity of the PDDF analysis beyond pairs of AuNPs. We obtain information about AuNP distances with an uncertainty margin of 1.2 nm. This readout accuracy in turn can be used for high precision placement of AuNP by careful design of the AuNP attachment sites on the DNA-structure and by fine-tuning of the connector types.
Yamamoto, Kyosuke; Togami, Takashi; Yamaguchi, Norio
2017-11-06
Unmanned aerial vehicles (UAVs or drones) are a very promising branch of technology, and they have been utilized in agriculture-in cooperation with image processing technologies-for phenotyping and vigor diagnosis. One of the problems in the utilization of UAVs for agricultural purposes is the limitation in flight time. It is necessary to fly at a high altitude to capture the maximum number of plants in the limited time available, but this reduces the spatial resolution of the captured images. In this study, we applied a super-resolution method to the low-resolution images of tomato diseases to recover detailed appearances, such as lesions on plant organs. We also conducted disease classification using high-resolution, low-resolution, and super-resolution images to evaluate the effectiveness of super-resolution methods in disease classification. Our results indicated that the super-resolution method outperformed conventional image scaling methods in spatial resolution enhancement of tomato disease images. The results of disease classification showed that the accuracy attained was also better by a large margin with super-resolution images than with low-resolution images. These results indicated that our approach not only recovered the information lost in low-resolution images, but also exerted a beneficial influence on further image analysis. The proposed approach will accelerate image-based phenotyping and vigor diagnosis in the field, because it not only saves time to capture images of a crop in a cultivation field but also secures the accuracy of these images for further analysis.
Togami, Takashi; Yamaguchi, Norio
2017-01-01
Unmanned aerial vehicles (UAVs or drones) are a very promising branch of technology, and they have been utilized in agriculture—in cooperation with image processing technologies—for phenotyping and vigor diagnosis. One of the problems in the utilization of UAVs for agricultural purposes is the limitation in flight time. It is necessary to fly at a high altitude to capture the maximum number of plants in the limited time available, but this reduces the spatial resolution of the captured images. In this study, we applied a super-resolution method to the low-resolution images of tomato diseases to recover detailed appearances, such as lesions on plant organs. We also conducted disease classification using high-resolution, low-resolution, and super-resolution images to evaluate the effectiveness of super-resolution methods in disease classification. Our results indicated that the super-resolution method outperformed conventional image scaling methods in spatial resolution enhancement of tomato disease images. The results of disease classification showed that the accuracy attained was also better by a large margin with super-resolution images than with low-resolution images. These results indicated that our approach not only recovered the information lost in low-resolution images, but also exerted a beneficial influence on further image analysis. The proposed approach will accelerate image-based phenotyping and vigor diagnosis in the field, because it not only saves time to capture images of a crop in a cultivation field but also secures the accuracy of these images for further analysis. PMID:29113104
Nonparametric predictive inference for combining diagnostic tests with parametric copula
NASA Astrophysics Data System (ADS)
Muhammad, Noryanti; Coolen, F. P. A.; Coolen-Maturi, T.
2017-09-01
Measuring the accuracy of diagnostic tests is crucial in many application areas including medicine and health care. The Receiver Operating Characteristic (ROC) curve is a popular statistical tool for describing the performance of diagnostic tests. The area under the ROC curve (AUC) is often used as a measure of the overall performance of the diagnostic test. In this paper, we interest in developing strategies for combining test results in order to increase the diagnostic accuracy. We introduce nonparametric predictive inference (NPI) for combining two diagnostic test results with considering dependence structure using parametric copula. NPI is a frequentist statistical framework for inference on a future observation based on past data observations. NPI uses lower and upper probabilities to quantify uncertainty and is based on only a few modelling assumptions. While copula is a well-known statistical concept for modelling dependence of random variables. A copula is a joint distribution function whose marginals are all uniformly distributed and it can be used to model the dependence separately from the marginal distributions. In this research, we estimate the copula density using a parametric method which is maximum likelihood estimator (MLE). We investigate the performance of this proposed method via data sets from the literature and discuss results to show how our method performs for different family of copulas. Finally, we briefly outline related challenges and opportunities for future research.
Gong, Yuanzheng; Hu, Danying; Hannaford, Blake; Seibel, Eric J.
2014-01-01
Abstract. Brain tumor margin removal is challenging because diseased tissue is often visually indistinguishable from healthy tissue. Leaving residual tumor leads to decreased survival, and removing normal tissue causes life-long neurological deficits. Thus, a surgical robotics system with a high degree of dexterity, accurate navigation, and highly precise resection is an ideal candidate for image-guided removal of fluorescently labeled brain tumor cells. To image, we developed a scanning fiber endoscope (SFE) which acquires concurrent reflectance and fluorescence wide-field images at a high resolution. This miniature flexible endoscope was affixed to the arm of a RAVEN II surgical robot providing programmable motion with feedback control using stereo-pair surveillance cameras. To verify the accuracy of the three-dimensional (3-D) reconstructed surgical field, a multimodal physical-sized model of debulked brain tumor was used to obtain the 3-D locations of residual tumor for robotic path planning to remove fluorescent cells. Such reconstruction is repeated intraoperatively during margin clean-up so the algorithm efficiency and accuracy are important to the robotically assisted surgery. Experimental results indicate that the time for creating this 3-D surface can be reduced to one-third by using known trajectories of a robot arm, and the error from the reconstructed phantom is within 0.67 mm in average compared to the model design. PMID:26158071
[Hyperspectral remote sensing image classification based on SVM optimized by clonal selection].
Liu, Qing-Jie; Jing, Lin-Hai; Wang, Meng-Fei; Lin, Qi-Zhong
2013-03-01
Model selection for support vector machine (SVM) involving kernel and the margin parameter values selection is usually time-consuming, impacts training efficiency of SVM model and final classification accuracies of SVM hyperspectral remote sensing image classifier greatly. Firstly, based on combinatorial optimization theory and cross-validation method, artificial immune clonal selection algorithm is introduced to the optimal selection of SVM (CSSVM) kernel parameter a and margin parameter C to improve the training efficiency of SVM model. Then an experiment of classifying AVIRIS in India Pine site of USA was performed for testing the novel CSSVM, as well as a traditional SVM classifier with general Grid Searching cross-validation method (GSSVM) for comparison. And then, evaluation indexes including SVM model training time, classification overall accuracy (OA) and Kappa index of both CSSVM and GSSVM were all analyzed quantitatively. It is demonstrated that OA of CSSVM on test samples and whole image are 85.1% and 81.58, the differences from that of GSSVM are both within 0.08% respectively; And Kappa indexes reach 0.8213 and 0.7728, the differences from that of GSSVM are both within 0.001; While the ratio of model training time of CSSVM and GSSVM is between 1/6 and 1/10. Therefore, CSSVM is fast and accurate algorithm for hyperspectral image classification and is superior to GSSVM.
Accuracy of experimental mandibular osteotomy using the image-guided sagittal saw.
Pietruski, P; Majak, M; Swiatek-Najwer, E; Popek, M; Szram, D; Zuk, M; Jaworowski, J
2016-06-01
The aim of this study was to perform an objective assessment of the accuracy of mandibular osteotomy simulations performed using an image-guided sagittal saw. A total of 16 image-guided mandibular osteotomies were performed on four prefabricated anatomical models according to the virtual plan. Postoperative computed tomography (CT) image data were fused with the preoperative CT scan allowing an objective comparison of the results of the osteotomy executed with the virtual plan. For each operation, the following parameters were analyzed and compared independently twice by two observers: resected bone volume, osteotomy trajectory angle, and marginal point positions. The mean target registration error was 0.95±0.19mm. For all osteotomies performed, the mean difference between the planned and actual bone resection volumes was 8.55±5.51%, the mean angular deviation between planned and actual osteotomy trajectory was 8.08±5.50°, and the mean difference between the preoperative and the postoperative marginal point positions was 2.63±1.27mm. In conclusion, despite the initial stages of the research, encouraging results were obtained. The current limitations of the navigated saw are discussed, as well as the improvements in technology that should increase its predictability and efficiency, making it a reliable method for improving the surgical outcomes of maxillofacial operations. Copyright © 2016 International Association of Oral and Maxillofacial Surgeons. Published by Elsevier Ltd. All rights reserved.
Kang, Jinbum; Lee, Jae Young; Yoo, Yangmo
2016-06-01
Effective speckle reduction in ultrasound B-mode imaging is important for enhancing the image quality and improving the accuracy in image analysis and interpretation. In this paper, a new feature-enhanced speckle reduction (FESR) method based on multiscale analysis and feature enhancement filtering is proposed for ultrasound B-mode imaging. In FESR, clinical features (e.g., boundaries and borders of lesions) are selectively emphasized by edge, coherence, and contrast enhancement filtering from fine to coarse scales while simultaneously suppressing speckle development via robust diffusion filtering. In the simulation study, the proposed FESR method showed statistically significant improvements in edge preservation, mean structure similarity, speckle signal-to-noise ratio, and contrast-to-noise ratio (CNR) compared with other speckle reduction methods, e.g., oriented speckle reducing anisotropic diffusion (OSRAD), nonlinear multiscale wavelet diffusion (NMWD), the Laplacian pyramid-based nonlinear diffusion and shock filter (LPNDSF), and the Bayesian nonlocal means filter (OBNLM). Similarly, the FESR method outperformed the OSRAD, NMWD, LPNDSF, and OBNLM methods in terms of CNR, i.e., 10.70 ± 0.06 versus 9.00 ± 0.06, 9.78 ± 0.06, 8.67 ± 0.04, and 9.22 ± 0.06 in the phantom study, respectively. Reconstructed B-mode images that were developed using the five speckle reduction methods were reviewed by three radiologists for evaluation based on each radiologist's diagnostic preferences. All three radiologists showed a significant preference for the abdominal liver images obtained using the FESR methods in terms of conspicuity, margin sharpness, artificiality, and contrast, p<0.0001. For the kidney and thyroid images, the FESR method showed similar improvement over other methods. However, the FESR method did not show statistically significant improvement compared with the OBNLM method in margin sharpness for the kidney and thyroid images. These results demonstrate that the proposed FESR method can improve the image quality of ultrasound B-mode imaging by enhancing the visualization of lesion features while effectively suppressing speckle noise.
Opfermann, Justin D.; Leonard, Simon; Decker, Ryan S.; Uebele, Nicholas A.; Bayne, Christopher E.; Joshi, Arjun S.; Krieger, Axel
2017-01-01
This paper specifies a surgical robot performing semi-autonomous electrosurgery for tumor resection and evaluates its accuracy using a visual servoing paradigm. We describe the design and integration of a novel, multi-degree of freedom electrosurgical tool for the smart tissue autonomous robot (STAR). Standardized line tests are executed to determine ideal cut parameters in three different types of porcine tissue. STAR is then programmed with the ideal cut setting for porcine tissue and compared against expert surgeons using open and laparoscopic techniques in a line cutting task. We conclude with a proof of concept demonstration using STAR to semi-autonomously resect pseudo-tumors in porcine tissue using visual servoing. When tasked to excise tumors with a consistent 4mm margin, STAR can semi-autonomously dissect tissue with an average margin of 3.67 mm and a standard deviation of 0.89mm. PMID:29503760
Zhu, Bohui; Ding, Yongsheng; Hao, Kuangrong
2013-01-01
This paper presents a novel maximum margin clustering method with immune evolution (IEMMC) for automatic diagnosis of electrocardiogram (ECG) arrhythmias. This diagnostic system consists of signal processing, feature extraction, and the IEMMC algorithm for clustering of ECG arrhythmias. First, raw ECG signal is processed by an adaptive ECG filter based on wavelet transforms, and waveform of the ECG signal is detected; then, features are extracted from ECG signal to cluster different types of arrhythmias by the IEMMC algorithm. Three types of performance evaluation indicators are used to assess the effect of the IEMMC method for ECG arrhythmias, such as sensitivity, specificity, and accuracy. Compared with K-means and iterSVR algorithms, the IEMMC algorithm reflects better performance not only in clustering result but also in terms of global search ability and convergence ability, which proves its effectiveness for the detection of ECG arrhythmias. PMID:23690875
Perforated marginal ulcers after laparoscopic gastric bypass.
Felix, Edward L; Kettelle, John; Mobley, Elijah; Swartz, Daniel
2008-10-01
Perforated marginal ulcer (PMU) after laparoscopic Roux-en-Y gastric bypass (LRYGB) is a serious complication, but its incidence and etiology have rarely been investigated. Therefore, a retrospective review of all patients undergoing LRYGB at the authors' center was conducted to determine the incidence of PMU and whether any causative factors were present. A prospectively kept database of all patients at the authors' bariatric center was retrospectively reviewed. The complete records of patients with a PMU were examined individually for accuracy and analyzed for treatment, outcome, and possible underlying causes of the marginal perforation. Between April 1999 and August 2007, 1% of the patients (35/3,430) undergoing laparoscopic gastric bypass experienced one or more perforated marginal ulcers 3 to 70 months (median, 18 months) after LRYGB. The patients with and without perforation were not significantly different in terms of mean age (37 vs 41 years), weight (286 vs 287 lb), body mass index (BMI) (46 vs 47), or female gender (89% vs 83%). Of the patients with perforations, 2 (6%) were taking steroids, 10 (29%) were receiving nonsteroidal antiinflammatory drugs (NSAIDs) at the time of the perforation, 18 (51%) were actively smoking, and 6 of the smokers also were taking NSAIDs. Eleven of the patients (31%) who perforated did not have at least one of these possible risk factors, but 4 (36%) of the 11 patients in this group had been treated after bypass for a marginal ulcer. Only 7 (20%) of the 35 patients who had laparoscopic bypass, or 7 (0.2%) in the entire group of 3,430 patients, perforated without any warning. There were no deaths, but three patients reperforated. The incidence of a marginal ulcer perforating after LRYGB was significant (>1%) and appeared to be related to smoking or the use of NSAIDs or steroids. Because only 0.2% of all patients acutely perforated without some risk factor or warning, long-term ulcer prophylaxis or treatment may be necessary for only a select group of high-risk patients.
ERIC Educational Resources Information Center
Cybart-Persenaire, Alena; Literat, Ioana
2018-01-01
This study examines the impact that producing a print newspaper using cell phones had on marginalized students in a high school journalism classroom. Analysis of data from participant observation, artifact analysis and student interviews revealed that a) students negotiated cell phone use for educational purposes, despite school bans on such…
Flight-determined stability analysis of multiple-input-multiple-output control systems
NASA Technical Reports Server (NTRS)
Burken, John J.
1992-01-01
Singular value analysis can give conservative stability margin results. Applying structure to the uncertainty can reduce this conservatism. This paper presents flight-determined stability margins for the X-29A lateral-directional, multiloop control system. These margins are compared with the predicted unscaled singular values and scaled structured singular values. The algorithm was further evaluated with flight data by changing the roll-rate-to-aileron command-feedback gain by +/- 20 percent. Minimum eigenvalues of the return difference matrix which bound the singular values are also presented. Extracting multiloop singular values from flight data and analyzing the feedback gain variations validates this technique as a measure of robustness. This analysis can be used for near-real-time flight monitoring and safety testing.
Flight-determined stability analysis of multiple-input-multiple-output control systems
NASA Technical Reports Server (NTRS)
Burken, John J.
1992-01-01
Singular value analysis can give conservative stability margin results. Applying structure to the uncertainty can reduce this conservatism. This paper presents flight-determined stability margins for the X-29A lateral-directional, multiloop control system. These margins are compared with the predicted unscaled singular values and scaled structured singular values. The algorithm was further evaluated with flight data by changing the roll-rate-to-aileron-command-feedback gain by +/- 20 percent. Also presented are the minimum eigenvalues of the return difference matrix which bound the singular values. Extracting multiloop singular values from flight data and analyzing the feedback gain variations validates this technique as a measure of robustness. This analysis can be used for near-real-time flight monitoring and safety testing.
Risk Informed Margins Management as part of Risk Informed Safety Margin Characterization
DOE Office of Scientific and Technical Information (OSTI.GOV)
Curtis Smith
2014-06-01
The ability to better characterize and quantify safety margin is important to improved decision making about Light Water Reactor (LWR) design, operation, and plant life extension. A systematic approach to characterization of safety margins and the subsequent margin management options represents a vital input to the licensee and regulatory analysis and decision making that will be involved. In addition, as research and development in the LWR Sustainability (LWRS) Program and other collaborative efforts yield new data, sensors, and improved scientific understanding of physical processes that govern the aging and degradation of plant SSCs needs and opportunities to better optimize plantmore » safety and performance will become known. To support decision making related to economics, readability, and safety, the Risk Informed Safety Margin Characterization (RISMC) Pathway provides methods and tools that enable mitigation options known as risk informed margins management (RIMM) strategies.« less
Legarra, A; Baloche, G; Barillet, F; Astruc, J M; Soulas, C; Aguerre, X; Arrese, F; Mintegi, L; Lasarte, M; Maeztu, F; Beltrán de Heredia, I; Ugarte, E
2014-05-01
Genotypes, phenotypes and pedigrees of 6 breeds of dairy sheep (including subdivisions of Latxa, Manech, and Basco-Béarnaise) from the Spain and France Western Pyrenees were used to estimate genetic relationships across breeds (together with genotypes from the Lacaune dairy sheep) and to verify by forward cross-validation single-breed or multiple-breed genetic evaluations. The number of rams genotyped fluctuated between 100 and 1,300 but generally represented the 10 last cohorts of progeny-tested rams within each breed. Genetic relationships were assessed by principal components analysis of the genomic relationship matrices and also by the conservation of linkage disequilibrium patterns at given physical distances in the genome. Genomic and pedigree-based evaluations used daughter yield performances of all rams, although some of them were not genotyped. A pseudo-single step method was used in this case for genomic predictions. Results showed a clear structure in blond and black breeds for Manech and Latxa, reflecting historical exchanges, and isolation of Basco-Béarnaise and Lacaune. Relatedness between any 2 breeds was, however, lower than expected. Single-breed genomic predictions had accuracies comparable with other breeds of dairy sheep or small breeds of dairy cattle. They were more accurate than pedigree predictions for 5 out of 6 breeds, with absolute increases in accuracy ranging from 0.05 to 0.30 points. They were significantly better, as assessed by bootstrapping of candidates, for 2 of the breeds. Predictions using multiple populations only marginally increased the accuracy for a couple of breeds. Pooling populations does not increase the accuracy of genomic evaluations in dairy sheep; however, single-breed genomic predictions are more accurate, even for small breeds, and make the consideration of genomic schemes in dairy sheep interesting. Copyright © 2014 American Dairy Science Association. Published by Elsevier Inc. All rights reserved.
Accuracy of endoscopic intraoperative assessment of urologic stone size.
Patel, Nishant; Chew, Ben; Knudsen, Bodo; Lipkin, Michael; Wenzler, David; Sur, Roger L
2014-05-01
Endoscopic treatment of renal calculi relies on surgeon assessment of residual stone fragment size for either basket removal or for the passage of fragments postoperatively. We therefore sought to determine the accuracy of endoscopic assessment of renal calculi size. Between January and May 2013, five board-certified endourologists participated in an ex vivo artificial endoscopic simulation. A total of 10 stones (pebbles) were measured (mm) by nonparticipating urologist (N.D.P.) with electronic calibers and placed into separate labeled opaque test tubes to prevent visualization of the stones through the side of the tube. Endourologists were blinded to the actual size of the stones. A flexible digital ureteroscope with a 200-μm core sized laser fiber in the working channel as a size reference was placed through the ureteroscope into the test tube to estimate the stone size (mm). Accuracy was determined by obtaining the correlation coefficient (r) and constructing an Altman-Bland plot. Endourologists tended to overestimate actual stone size by a margin of 0.05 mm. The Pearson correlation coefficient was r=0.924, with a p-value<0.01. The estimation of small stones (<4 mm) had a greater accuracy than large stones (≥4 mm), r=0.911 vs r=0.666. Altman-bland plot analysis suggests that surgeons are able to accurately estimate stone size within a range of -1.8 to +1.9 mm. This ex vivo simulation study demonstrates that endoscopic assessment is reliable when assessing stone size. On average, there was a slight tendency to overestimate stone size by 0.05 mm. Most endourologists could visually estimate stone size within 2 mm of the actual size. These findings could be generalized to state that endourologists are accurately able to intraoperatively assess residual stone fragment size to guide decision making.
Mously, Hisham A; Finkelman, Matthew; Zandparsa, Roya; Hirayama, Hiroshi
2014-08-01
The accuracy of chairside computer-aided design and computer-aided manufacturing (CAD/CAM) restorations is questionable, and the effect of the die spacer settings is not well stated in the literature. The purpose of the study was to evaluate the marginal and internal adaptation of E4D crowns fabricated with different spacer thicknesses and to compare these crowns with those fabricated with the heat-press technique. The E4D system was used to fabricate 30 crowns for the first 3 groups, with different spacer thickness settings: 30 μm, 60 μm, and 100 μm. In the fourth group, 10 lithium disilicate crowns were fabricated with the heat-press technique. The occlusal gap, axial gap, vertical marginal gap, and absolute marginal discrepancy were evaluated by x-ray microtomography. Statistical significance was assessed with the Kruskal-Wallis test (α=.05). For post hoc analyses, the Mann-Whitney U test was used alongside the Bonferroni correction for multiple comparisons (α=.008). Within the CAD/CAM groups, the 30-μm spacer thickness resulted in the lowest median axial gap (90.04 μm), whereas the 60-μm spacer thickness resulted in the lowest median occlusal gap (152.39 μm). The median marginal gap values of the CAD/CAM-60 group (49.35 μm) and CAD/CAM-100 group (46.65 μm) were lower than those of the CAD/CAM-30 group (55.18 μm). No significant differences among the CAD/CAM groups were observed for absolute marginal discrepancy. The heat-press group had significantly different values than those of the CAD/CAM groups. The spacer thickness and fabrication technique affected the adaptation of ceramic crowns. The heat-press group yielded the best marginal and internal crown adaptation results. The 30- or 60-μm spacer settings are recommended for the E4D CAD/CAM system. Copyright © 2014 Editorial Council for the Journal of Prosthetic Dentistry. Published by Elsevier Inc. All rights reserved.
1986-12-01
optimal value can be stated as, Marginal Productivity of Marginal Productivity of Good A Good B " Price of Good A Price of Good B This...contractor proposed production costs could be used. _11 i4 W Vi..:. II. CONTRACT PROPOSAL EVALUATION A. PRICE ANALYSIS Price analysis, in its broadest sense...enters the market with a supply function represented by line S2, then the new price will be reestablished at price OP2 and quantity OQ2. Price
Positive Surgical Margins in Favorable-Stage Differentiated Thyroid Cancer.
Mercado, Catherine E; Drew, Peter A; Morris, Christopher G; Dziegielewski, Peter T; Mendenhall, William M; Amdur, Robert J
2018-04-16
The significance of positive margin in favorable-stage well-differentiated thyroid cancer is controversial. We report outcomes of positive-margin patients with a matched-pair comparison to a negative-margin group. A total of 25 patients with classic-histology papillary or follicular carcinoma, total thyroidectomy +/- node dissection, stage T1-3N0-1bM0, positive surgical margin at primary site, adjuvant radioactive iodine (I-131), and age older than 18 years were treated between 2003 and 2013. Endpoints were clinical and biochemical (thyroglobulin-only) recurrence-free survival. Matched-pair analysis involved a 1:1 match with negative-margin cases matched for overall stage and I-131 dose. Recurrence-free survival in positive-margin patients was 71% at 10 years. No patient was successfully salvaged with additional treatment. Only 1 patient died of thyroid cancer. Recurrence-free survival at 10 years was worse with a positive (71%) versus negative (90%) margin (P=0.140). Cure with a microscopically positive margin was suboptimal (71%) despite patients having classic-histology papillary and follicular carcinoma, favorable stage, and moderate-dose I-131 therapy.
Methods for determining time of death.
Madea, Burkhard
2016-12-01
Medicolegal death time estimation must estimate the time since death reliably. Reliability can only be provided empirically by statistical analysis of errors in field studies. Determining the time since death requires the calculation of measurable data along a time-dependent curve back to the starting point. Various methods are used to estimate the time since death. The current gold standard for death time estimation is a previously established nomogram method based on the two-exponential model of body cooling. Great experimental and practical achievements have been realized using this nomogram method. To reduce the margin of error of the nomogram method, a compound method was developed based on electrical and mechanical excitability of skeletal muscle, pharmacological excitability of the iris, rigor mortis, and postmortem lividity. Further increasing the accuracy of death time estimation involves the development of conditional probability distributions for death time estimation based on the compound method. Although many studies have evaluated chemical methods of death time estimation, such methods play a marginal role in daily forensic practice. However, increased precision of death time estimation has recently been achieved by considering various influencing factors (i.e., preexisting diseases, duration of terminal episode, and ambient temperature). Putrefactive changes may be used for death time estimation in water-immersed bodies. Furthermore, recently developed technologies, such as H magnetic resonance spectroscopy, can be used to quantitatively study decompositional changes. This review addresses the gold standard method of death time estimation in forensic practice and promising technological and scientific developments in the field.
Factors affecting surgical margin recurrence after hepatectomy for colorectal liver metastases
Akyuz, Muhammet; Aucejo, Federico; Quintini, Cristiano; Miller, Charles; Fung, John
2016-01-01
Background Hepatic recurrence after resection of colorectal liver metastasis (CLM) occurs in 50% of patients during follow-up, with 2.8% to 13.9% presenting with surgical margin recurrence (SMR). The aim of this study is to analyze factors that related to SMR in patients with CLM undergoing hepatectomy. Methods Demographics, clinical and survival data of patients who underwent hepatectomy were identified from a prospectively maintained, institutional review board (IRB)-approved database between 2000 and 2012. Statistical analysis was performed using univariate Kaplan Meier and Cox proportional hazard model. Results There were 85 female and 121 male patients who underwent liver resection for CLM. An R0 resection was performed in 157 (76%) patients and R1 resection in 49. SMR was detected in 32 patients (15.5%) followed up for a median of 29 months (range, 3–121 months). A half of these patients had undergone R1 (n=16) and another half R0 resection (n=16). Tumor size, preoperative carcinoembryonic antigen (CEA) level and margin status were associated with SMR on univariate analysis. On multivariate analysis, a positive surgical margin was the only independent predictor of SMR. The receipt of adjuvant chemotherapy did not affect margin recurrence. SMR was an independent risk factor associated with worse disease-free (DFS) and overall survival (OS). Conclusions This study shows that SMR, which can be detected in up to 15.5% of patients after liver resection for CLM, adversely affects DFS and OS. The fact that a positive surgical margin was the only predictive factor for SMR in these patients underscores the importance of achieving negative margins during hepatectomy. PMID:27294032
Wu, Jie; Chen, Qi-Xun; Teng, Li-song; Krasna, Mark J
2014-02-01
To assess the prognostic significance of positive circumferential resection margin on overall survival in patients with esophageal cancer, a systematic review and meta-analysis was performed. Studies were identified from PubMed, EMBASE, and Web of Science. Survival data were extracted from eligible studies to compare overall survival in patients with a positive circumferential resection margin with patients having a negative circumferential resection margin according to the Royal College of Pathologists (RCP) criteria and the College of American Pathologists (CAP) criteria. Survival data were pooled with hazard ratios (HRs) and their corresponding 95% confidence intervals (CIs). A random-effects model meta-analysis on overall survival was performed. The pooled HRs for survival were 1.510 (95% CI, 1.329-1.717; p<0.001) and 2.053 (95% CI, 1.597-2.638; p<0.001) according to the RCP and CAP criteria, respectively. Positive circumferential resection margin was associated with worse survival in patients with T3 stage disease according to the RCP (HR, 1.381; 95% CI, 1.028-1.584; p=0.001) and CAP (HR, 2.457; 95% CI, 1.902-3.175; p<0.001) criteria, respectively. Positive circumferential resection margin was associated with worse survival in patients receiving neoadjuvant therapy according to the RCP (HR, 1.676; 95% CI, 1.023-2.744; p=0.040) and CAP (HR, 1.847; 95% CI, 1.226-2.78; p=0.003) criteria, respectively. Positive circumferential resection margin is associated with poor prognosis in patients with esophageal cancer, particularly in patients with T3 stage disease and patients receiving neoadjuvant therapy. Copyright © 2014 The Society of Thoracic Surgeons. Published by Elsevier Inc. All rights reserved.
Satellite imagery of the onset of streaming flow of ice streams C and D, West Antarctica
Hodge, S.M.; Doppelhammer, S.K.
1996-01-01
Five overlapping Landsat multispectral scanner satellite images of the interior of the West Antarctic ice sheet were enhanced with principal component analysis, high-pass filtering, and linear contrast stretching and merged into a mosaic by aligning surface features in the overlap areas. The mosaic was registered to geodetic coordinates, to an accuracy of about 1 km, using the five scene centers as control points. The onset of streaming flow of two tributaries of ice stream C and one tributary of ice stream D is visible in the mosaic. The onset appears to occur within a relatively short distance, less than the width of the ice stream, typically at a subglacial topographic feature such as a step or ridge. The ice streams extend farther up into the interior than previously mapped. Ice stream D starts about 150 km from the ice divide, at an altitude of about 1500 m, approximately halfway up the convex-upward dome shape of the interior ice sheet. Ice stream D is relatively much longer than ice stream C, possibly because ice stream D is currently active whereas ice stream C is currently inactive. The grounded portion of the West Antarctic ice sheet is perhaps best conceptualized as an ice sheet in which ice streams are embedded over most of its area, with slow moving ice converging into fast moving ice streams in a widely distributed pattern, much like that of streams and rivers in a hydrologic basin. A relic margin appears to parallel most of the south margin of the tributary of ice stream D, separated from the active shear margin by about 10 km or less for a distance of over 200 km. This means there is now evidence for recent changes having occurred in three of the five major ice streams which drain most of West Antarctica (B, C, and D), two of which (B and D) are currently active.
NASA Astrophysics Data System (ADS)
Maestro, A.; Jané, G.; Llave, E.; López-Martínez, J.; Bohoyo, F.; Druet, M.
2018-06-01
The identification of recent major tectonic structures in the Galicia continental margin and adjacent abyssal plains was carried out by means of a quantitative analysis of the linear structures having bathymetric expression on the seabed. It was possible to identify about 5800 lineaments throughout the entire study area, of approximately 271,500 km2. Most lineaments are located in the Charcot and Coruña highs, in the western sector of the Galicia Bank, in the area of the Marginal Platforms and in the northern sector of the margin. Analysis of the lineament orientations shows a predominant NE-SW direction and three relative maximum directions: NW-SE, E-W and N-S. The total length of the lineaments identified is over 44,000 km, with a mode around 5000 m and an average length of about 7800 m. In light of different tectonic studies undertaken in the northwestern margin of the Iberian Peninsula, we establish that the lineaments obtained from analysis of the digital bathymetric model of the Galicia continental margin and adjacent abyssal plains would correspond to fracture systems. In general, the orientation of lineaments corresponds to main faults, tectonic structures following the directions of ancient faults that resulted from late stages of the Variscan orogeny and Mesozoic extension phases related to Triassic rifting and Upper Jurassic to Early Cretaceous opening of the North Atlantic Ocean. The N-S convergence between Eurasian and African plates since Palaeogene times until the Miocene, and NW-SE convergence from Neogene to present, reactivated the Variscan and Mesozoic fault systems and related physiography.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Szilard, Ronaldo Henriques
A Risk Informed Safety Margin Characterization (RISMC) toolkit and methodology are proposed for investigating nuclear power plant core, fuels design and safety analysis, including postulated Loss-of-Coolant Accident (LOCA) analysis. This toolkit, under an integrated evaluation model framework, is name LOCA toolkit for the US (LOTUS). This demonstration includes coupled analysis of core design, fuel design, thermal hydraulics and systems analysis, using advanced risk analysis tools and methods to investigate a wide range of results.
Estimation of Inherent Safety Margins in Loaded Commercial Spent Nuclear Fuel Casks
Banerjee, Kaushik; Robb, Kevin R.; Radulescu, Georgeta; ...
2016-06-15
We completed a novel assessment to determine the unquantified and uncredited safety margins (i.e., the difference between the licensing basis and as-loaded calculations) available in as-loaded spent nuclear fuel (SNF) casks. This assessment was performed as part of a broader effort to assess issues and uncertainties related to the continued safety of casks during extended storage and transportability following extended storage periods. Detailed analyses crediting the actual as-loaded cask inventory were performed for each of the casks at three decommissioned pressurized water reactor (PWR) sites to determine their characteristics relative to regulatory safety criteria for criticality, thermal, and shielding performance.more » These detailed analyses were performed in an automated fashion by employing a comprehensive and integrated data and analysis tool—Used Nuclear Fuel-Storage, Transportation & Disposal Analysis Resource and Data System (UNF-ST&DARDS). Calculated uncredited criticality margins from 0.07 to almost 0.30 Δk eff were observed; calculated decay heat margins ranged from 4 to almost 22 kW (as of 2014); and significant uncredited transportation dose rate margins were also observed. The results demonstrate that, at least for the casks analyzed here, significant uncredited safety margins are available that could potentially be used to compensate for SNF assembly and canister structural performance related uncertainties associated with long-term storage and subsequent transportation. The results also suggest that these inherent margins associated with how casks are loaded could support future changes in cask licensing to directly or indirectly credit the margins. Work continues to quantify the uncredited safety margins in the SNF casks loaded at other nuclear reactor sites.« less
Evaluation and comparison of the marginal adaptation of two different substructure materials.
Karaman, Tahir; Ulku, Sabiha Zelal; Zengingul, Ali Ihsan; Guven, Sedat; Eratilla, Veysel; Sumer, Ebru
2015-06-01
In this study, we aimed to evaluate the amount of marginal gap with two different substructure materials using identical margin preparations. Twenty stainless steel models with a chamfer were prepared with a CNC device. Marginal gap measurements of the galvano copings on these stainless steel models and Co-Cr copings obtained by a laser-sintering method were made with a stereomicroscope device before and after the cementation process and surface properties were evaluated by scanning electron microscopy (SEM). A dependent t-test was used to compare the mean of the two groups for normally distributed data, and two-way variance analysis was used for more than two data sets. Pearson's correlation analysis was also performed to assess relationships between variables. According to the results obtained, the marginal gap in the galvano copings before cementation was measured as, on average, 24.47 ± 5.82 µm before and 35.11 ± 6.52 µm after cementation; in the laser-sintered Co-Cr structure, it was, on average, 60.45 ± 8.87 µm before and 69.33 ± 9.03 µm after cementation. A highly significant difference (P<.001) was found in marginal gap measurements of galvano copings and a significant difference (P<.05) was found in marginal gap measurements of the laser-sintered Co-Cr copings. According to the SEM examination, surface properties of laser sintered Co-Cr copings showed rougher structure than galvano copings. The galvano copings showed a very smooth surface. Marginal gaps values of both groups before and after cementation were within the clinically acceptable level. The smallest marginal gaps occurred with the use of galvano copings.
Evaluation and comparison of the marginal adaptation of two different substructure materials
Karaman, Tahir; Ulku, Sabiha Zelal; Zengingul, Ali Ihsan; Eratilla, Veysel; Sumer, Ebru
2015-01-01
PURPOSE In this study, we aimed to evaluate the amount of marginal gap with two different substructure materials using identical margin preparations. MATERIALS AND METHODS Twenty stainless steel models with a chamfer were prepared with a CNC device. Marginal gap measurements of the galvano copings on these stainless steel models and Co-Cr copings obtained by a laser-sintering method were made with a stereomicroscope device before and after the cementation process and surface properties were evaluated by scanning electron microscopy (SEM). A dependent t-test was used to compare the mean of the two groups for normally distributed data, and two-way variance analysis was used for more than two data sets. Pearson's correlation analysis was also performed to assess relationships between variables. RESULTS According to the results obtained, the marginal gap in the galvano copings before cementation was measured as, on average, 24.47 ± 5.82 µm before and 35.11 ± 6.52 µm after cementation; in the laser-sintered Co-Cr structure, it was, on average, 60.45 ± 8.87 µm before and 69.33 ± 9.03 µm after cementation. A highly significant difference (P<.001) was found in marginal gap measurements of galvano copings and a significant difference (P<.05) was found in marginal gap measurements of the laser-sintered Co-Cr copings. According to the SEM examination, surface properties of laser sintered Co-Cr copings showed rougher structure than galvano copings. The galvano copings showed a very smooth surface. CONCLUSION Marginal gaps values of both groups before and after cementation were within the clinically acceptable level. The smallest marginal gaps occurred with the use of galvano copings. PMID:26140178
Positive surgical margins after robotic assisted radical prostatectomy: a multi-institutional study.
Patel, Vipul R; Coelho, Rafael F; Rocco, Bernardo; Orvieto, Marcelo; Sivaraman, Ananthakrishnan; Palmer, Kenneth J; Kameh, Darien; Santoro, Luigi; Coughlin, Geoff D; Liss, Michael; Jeong, Wooju; Malcolm, John; Stern, Joshua M; Sharma, Saurabh; Zorn, Kevin C; Shikanov, Sergey; Shalhav, Arieh L; Zagaja, Gregory P; Ahlering, Thomas E; Rha, Koon H; Albala, David M; Fabrizio, Michael D; Lee, David I; Chauhan, Sanket
2011-08-01
Positive surgical margins are an independent predictive factor for biochemical recurrence after radical prostatectomy. We analyzed the incidence of and associative factors for positive surgical margins in a multi-institutional series of 8,418 robotic assisted radical prostatectomies. We analyzed the records of 8,418 patients who underwent robotic assisted radical prostatectomy at 7 institutions. Of the patients 323 had missing data on margin status. Positive surgical margins were categorized into 4 groups, including apex, bladder neck, posterolateral and multifocal. The records of 6,169 patients were available for multivariate analysis. The variables entered into the logistic regression models were age, body mass index, preoperative prostate specific antigen, biopsy Gleason score, prostate weight and pathological stage. A second model was built to identify predictive factors for positive surgical margins in the subset of patients with organ confined disease (pT2). The overall positive surgical margin rate was 15.7% (1,272 of 8,095 patients). The positive surgical margin rate for pT2 and pT3 disease was 9.45% and 37.2%, respectively. On multivariate analysis pathological stage (pT2 vs pT3 OR 4.588, p<0.001) and preoperative prostate specific antigen (4 or less vs greater than 10 ng/ml OR 2.918, p<0.001) were the most important independent predictive factors for positive surgical margins after robotic assisted radical prostatectomy. Increasing prostate weight was associated with a lower risk of positive surgical margins after robotic assisted radical prostatectomy (OR 0.984, p<0.001) and a higher body mass index was associated with a higher risk of positive surgical margins (OR 1.032, p<0.001). For organ confined disease preoperative prostate specific antigen was the most important factor that independently correlated with positive surgical margins (4 or less vs greater than 10 ng/ml OR 3.8, p<0.001). The prostatic apex followed by a posterolateral site was the most common location of positive surgical margins after robotic assisted radical prostatectomy. Factors that correlated with cancer aggressiveness, such as pathological stage and preoperative prostate specific antigen, were the most important factors independently associated with an increased risk of positive surgical margins after robotic assisted radical prostatectomy. Copyright © 2011 American Urological Association Education and Research, Inc. Published by Elsevier Inc. All rights reserved.
Tengher-Barna, Iulia; Hequet, Delphine; Reboul-Marty, Jeanne; Frassati-Biaggi, Annonciade; Seince, Nathalie; Rodrigues-Faure, Anabela; Uzan, Michèle; Ziol, Marianne
2009-02-01
Margin resection status is a major risk factor for the development of local recurrence in breast conservation therapy for carcinoma. Tumor bed excision sent as separate orientated cavity margins represents a tool to verify the completeness of the carcinoma resection. We aimed to (1) determine the prevalence of positive cavity margin and its influence on subsequent surgical treatment and (2) identify potential predictive factors for positive cavity margins. From 2003 to 2006, 107 (57 years; 30-88) consecutive patients who underwent a lumpectomy for carcinoma with four orientated cavity margins for carcinoma were selected. Preoperative clinical, radiological and histological data, perioperative macroscopic characteristics and definitive histological analysis results were recorded. Lumpectomy or cavity margins were considered as positive when the distance from carcinoma to the margin was less than or equal to 3 mm. Histological examination of cavity margins showed carcinoma in 38 patients (35%), therefore modifying subsequent surgical therapy in 33 cases. Examination of the cavity margins led (1) to avoiding surgical re-excision in 20 cases (lumpectomy margins were positive and the cavity margins negative), (2) to performing a mastectomy or a re-excision in 13 cases (carcinoma was detected in the cavity margins although the lumpectomy margins were negative or tumor size was superior to 3 cm). Between preoperative and perioperative parameters, US scan and macroscopic size of the tumor were predictive factors for positive cavity margins whereas characteristics of the carcinoma determined on biopsy samples and macroscopic status of the lumpectomy margins were not. Our study confirms that the systematic practice of cavity margin resection avoids surgical re-excision and reduces the likelihood of underestimating the extent of the tumor.
Song, Yang; Zhao, Yi-jiao; Sun, Yu-chun; Lü, Pei-jun; Wang, Yong
2013-09-01
To evaluate the design and manufacture accuracy of a domestic computer aided design (CAD) and computer aided manufacture (CAM) system, and to compare it with similar foreign products. Thirty models of posterior-teeth-single-crown preparations were collected, and STL data of these preparations was collected by Denmark 3Shape scanner. Three copings were made for each preparation, the one designed and manufactured using commercial CAD/CAM system (3Shape CAD software and Wieland T1 CAM equipment) was assigned into control group T0, the one designed and manufactured using domestic CAD software (developed by Peking University School and Hospital of Stomatology and Nanjing University of Aeronautics and Astronautics) and Wieland T1 CAM equipment was assigned into experimental group TCAD for design accuracy evaluation, and the one designed and manufactured using 3Shape CAD software and domestic CAM equipment (developed by Peking University School and Hospital of Stomatology, Tsinghua University and ShanDong XinHua Incorporated Company of medical apparatus and instruments) was assigned into experimental group TCAM for manufacture accuracy evaluation. Finally, the marginal fitness were compared and evaluated by using 3D & Profile measurement microscope laser. The marginal fitness of TCAD was 27.98 (19.10, 46.57) µm in buccal, 32.67 (20.65, 50.82) µm in lingual, 27.38 (22.53, 52.61) µm in mesial, 29.50 (22.68, 53.65) µm in distal; of TCAM was 21.69 (15.87, 30.21) µm in buccal, 18.51 (13.50, 22.51) µm in lingual, 19.15 (15.42, 26.89) µm in mesial, 22.77 (18.58, 32.15) µm in distal; and there were no statistical differences compared with T0 [20.16 (17.16, 48.00) µm in buccal, 21.51 (17.05, 28.31) µm in lingual, 23.54 (17.89, 30.04) µm in mesial and 23.94 (17.93, 28.19) µm in distal] except lingual data of TCAD. The design and machining precision of this domestic CAD/CAM system is at the same level of those comparable foreign products.
Jiang, Y; Zhao, Y; Rodemann, B; Plieske, J; Kollers, S; Korzun, V; Ebmeyer, E; Argillier, O; Hinze, M; Ling, J; Röder, M S; Ganal, M W; Mette, M F; Reif, J C
2015-03-01
Genome-wide mapping approaches in diverse populations are powerful tools to unravel the genetic architecture of complex traits. The main goals of our study were to investigate the potential and limits to unravel the genetic architecture and to identify the factors determining the accuracy of prediction of the genotypic variation of Fusarium head blight (FHB) resistance in wheat (Triticum aestivum L.) based on data collected with a diverse panel of 372 European varieties. The wheat lines were phenotyped in multi-location field trials for FHB resistance and genotyped with 782 simple sequence repeat (SSR) markers, and 9k and 90k single-nucleotide polymorphism (SNP) arrays. We applied genome-wide association mapping in combination with fivefold cross-validations and observed surprisingly high accuracies of prediction for marker-assisted selection based on the detected quantitative trait loci (QTLs). Using a random sample of markers not selected for marker-trait associations revealed only a slight decrease in prediction accuracy compared with marker-based selection exploiting the QTL information. The same picture was confirmed in a simulation study, suggesting that relatedness is a main driver of the accuracy of prediction in marker-assisted selection of FHB resistance. When the accuracy of prediction of three genomic selection models was contrasted for the three marker data sets, no significant differences in accuracies among marker platforms and genomic selection models were observed. Marker density impacted the accuracy of prediction only marginally. Consequently, genomic selection of FHB resistance can be implemented most cost-efficiently based on low- to medium-density SNP arrays.
Accuracy and robustness evaluation in stereo matching
NASA Astrophysics Data System (ADS)
Nguyen, Duc M.; Hanca, Jan; Lu, Shao-Ping; Schelkens, Peter; Munteanu, Adrian
2016-09-01
Stereo matching has received a lot of attention from the computer vision community, thanks to its wide range of applications. Despite of the large variety of algorithms that have been proposed so far, it is not trivial to select suitable algorithms for the construction of practical systems. One of the main problems is that many algorithms lack sufficient robustness when employed in various operational conditions. This problem is due to the fact that most of the proposed methods in the literature are usually tested and tuned to perform well on one specific dataset. To alleviate this problem, an extensive evaluation in terms of accuracy and robustness of state-of-the-art stereo matching algorithms is presented. Three datasets (Middlebury, KITTI, and MPEG FTV) representing different operational conditions are employed. Based on the analysis, improvements over existing algorithms have been proposed. The experimental results show that our improved versions of cross-based and cost volume filtering algorithms outperform the original versions with large margins on Middlebury and KITTI datasets. In addition, the latter of the two proposed algorithms ranks itself among the best local stereo matching approaches on the KITTI benchmark. Under evaluations using specific settings for depth-image-based-rendering applications, our improved belief propagation algorithm is less complex than MPEG's FTV depth estimation reference software (DERS), while yielding similar depth estimation performance. Finally, several conclusions on stereo matching algorithms are also presented.
Copeland, Sandi R; Sponheimer, Matt; le Roux, Petrus J; Grimes, Vaughan; Lee-Thorp, Julia A; de Ruiter, Darryl J; Richards, Michael P
2008-10-01
Strontium isotope ratios (87Sr/86Sr) in tooth enamel provide a means to investigate migration and landscape use in humans and other animals. Established methods for measuring (87)Sr/(86)Sr in teeth use bulk sampling (5-20 mg) and labor-intensive elemental purification procedures before analysis by either thermal ionization mass spectrometry (TIMS) or multicollector inductively coupled plasma mass spectrometry (MC-ICP-MS). Another method for measuring 87Sr/86Sr is laser ablation MC-ICP-MS, but concerns have been expressed about its accuracy for measuring tooth enamel. In this study we test the precision and accuracy of the technique by analyzing 30 modern rodent teeth from the Sterkfontein Valley, South Africa by laser ablation MC-ICP-MS and solution MC-ICP-MS. The results show a mean difference in 87Sr/86Sr measured by laser ablation and by solution of 0.0003 +/- 0.0002. This degree of precision is well within the margin necessary for investigating the potential geographic origins of humans or animals in many areas of the world. Because laser ablation is faster, less expensive, and less destructive than bulk sampling solution methods, it opens the possibility for conducting 87Sr/86Sr analyses of intra-tooth samples and small and/or rare specimens such as micromammal and fossil teeth.
Diagnostic accuracy of MRI in the measurement of glenoid bone loss.
Gyftopoulos, Soterios; Hasan, Saqib; Bencardino, Jenny; Mayo, Jason; Nayyar, Samir; Babb, James; Jazrawi, Laith
2012-10-01
The purpose of this study is to assess the accuracy of MRI quantification of glenoid bone loss and to compare the diagnostic accuracy of MRI to CT in the measurement of glenoid bone loss. MRI, CT, and 3D CT examinations of 18 cadaveric glenoids were obtained after the creation of defects along the anterior and anteroinferior glenoid. The defects were measured by three readers separately and blindly using the circle method. These measurements were compared with measurements made on digital photographic images of the cadaveric glenoids. Paired sample Student t tests were used to compare the imaging modalities. Concordance correlation coefficients were also calculated to measure interobserver agreement. Our data show that MRI could be used to accurately measure glenoid bone loss with a small margin of error (mean, 3.44%; range, 2.06-5.94%) in estimated percentage loss. MRI accuracy was similar to that of both CT and 3D CT for glenoid loss measurements in our study for the readers familiar with the circle method, with 1.3% as the maximum expected difference in accuracy of the percentage bone loss between the different modalities (95% confidence). Glenoid bone loss can be accurately measured on MRI using the circle method. The MRI quantification of glenoid bone loss compares favorably to measurements obtained using 3D CT and CT. The accuracy of the measurements correlates with the level of training, and a learning curve is expected before mastering this technique.
Gaber, Ramy M; Shaheen, Eman; Falter, Bart; Araya, Sebastian; Politis, Constantinus; Swennen, Gwen R J; Jacobs, Reinhilde
2017-11-01
The aim of this study was to systematically review methods used for assessing the accuracy of 3-dimensional virtually planned orthognathic surgery in an attempt to reach an objective assessment protocol that could be universally used. A systematic review of the currently available literature, published until September 12, 2016, was conducted using PubMed as the primary search engine. We performed secondary searches using the Cochrane Database, clinical trial registries, Google Scholar, and Embase, as well as a bibliography search. Included articles were required to have stated clearly that 3-dimensional virtual planning was used and accuracy assessment performed, along with validation of the planning and/or assessment method. Descriptive statistics and quality assessment of included articles were performed. The initial search yielded 1,461 studies. Only 7 studies were included in our review. An important variability was found regarding methods used for 1) accuracy assessment of virtually planned orthognathic surgery or 2) validation of the tools used. Included studies were of moderate quality; reviewers' agreement regarding quality was calculated to be 0.5 using the Cohen κ test. On the basis of the findings of this review, it is evident that the literature lacks consensus regarding accuracy assessment. Hence, a protocol is suggested for accuracy assessment of virtually planned orthognathic surgery with the lowest margin of error. Copyright © 2017 American Association of Oral and Maxillofacial Surgeons. Published by Elsevier Inc. All rights reserved.
Applicability of APT aided-inertial system to crustal movement monitoring
NASA Technical Reports Server (NTRS)
Soltz, J. A.
1978-01-01
The APT system, its stage of development, hardware, and operations are described. The algorithms required to perform the real-time functions of navigation and profiling are presented. The results of computer simulations demonstrate the feasibility of APT for its primary mission: topographic mapping with an accuracy of 15 cm in the vertical. Also discussed is the suitability of modifying APT for the purpose of making vertical crustal movement measurements accurate to 2 cm in the vertical, and at least marginal feasibility is indicated.
NASA Technical Reports Server (NTRS)
Klein, M.; Reynolds, J.; Ricks, E.
1989-01-01
Load and stress recovery from transient dynamic studies are improved upon using an extended acceleration vector in the modal acceleration technique applied to structural analysis. Extension of the normal LTM (load transformation matrices) stress recovery to automatically compute margins of safety is presented with an application to the Hubble space telescope.
Urinary Volatile Organic Compounds for the Detection of Prostate Cancer
Khalid, Tanzeela; Aggio, Raphael; White, Paul; De Lacy Costello, Ben; Persad, Raj; Al-Kateb, Huda; Jones, Peter; Probert, Chris S.; Ratcliffe, Norman
2015-01-01
The aim of this work was to investigate volatile organic compounds (VOCs) emanating from urine samples to determine whether they can be used to classify samples into those from prostate cancer and non-cancer groups. Participants were men referred for a trans-rectal ultrasound-guided prostate biopsy because of an elevated prostate specific antigen (PSA) level or abnormal findings on digital rectal examination. Urine samples were collected from patients with prostate cancer (n = 59) and cancer-free controls (n = 43), on the day of their biopsy, prior to their procedure. VOCs from the headspace of basified urine samples were extracted using solid-phase micro-extraction and analysed by gas chromatography/mass spectrometry. Classifiers were developed using Random Forest (RF) and Linear Discriminant Analysis (LDA) classification techniques. PSA alone had an accuracy of 62–64% in these samples. A model based on 4 VOCs, 2,6-dimethyl-7-octen-2-ol, pentanal, 3-octanone, and 2-octanone, was marginally more accurate 63–65%. When combined, PSA level and these four VOCs had mean accuracies of 74% and 65%, using RF and LDA, respectively. With repeated double cross-validation, the mean accuracies fell to 71% and 65%, using RF and LDA, respectively. Results from VOC profiling of urine headspace are encouraging and suggest that there are other metabolomic avenues worth exploring which could help improve the stratification of men at risk of prostate cancer. This study also adds to our knowledge on the profile of compounds found in basified urine, from controls and cancer patients, which is useful information for future studies comparing the urine from patients with other disease states. PMID:26599280
NASA Astrophysics Data System (ADS)
Realmuto, Vincent J.; Berk, Alexander
2016-11-01
We describe the development of Plume Tracker, an interactive toolkit for the analysis of multispectral thermal infrared observations of volcanic plumes and clouds. Plume Tracker is the successor to MAP_SO2, and together these flexible and comprehensive tools have enabled investigators to map sulfur dioxide (SO2) emissions from a number of volcanoes with TIR data from a variety of airborne and satellite instruments. Our objective for the development of Plume Tracker was to improve the computational performance of the retrieval procedures while retaining the accuracy of the retrievals. We have achieved a 300 × improvement in the benchmark performance of the retrieval procedures through the introduction of innovative data binning and signal reconstruction strategies, and improved the accuracy of the retrievals with a new method for evaluating the misfit between model and observed radiance spectra. We evaluated the accuracy of Plume Tracker retrievals with case studies based on MODIS and AIRS data acquired over Sarychev Peak Volcano, and ASTER data acquired over Kilauea and Turrialba Volcanoes. In the Sarychev Peak study, the AIRS-based estimate of total SO2 mass was 40% lower than the MODIS-based estimate. This result was consistent with a 45% reduction in the AIRS-based estimate of plume area relative to the corresponding MODIS-based estimate. In addition, we found that our AIRS-based estimate agreed with an independent estimate, based on a competing retrieval technique, within a margin of ± 20%. In the Kilauea study, the ASTER-based concentration estimates from 21 May 2012 were within ± 50% of concurrent ground-level concentration measurements. In the Turrialba study, the ASTER-based concentration estimates on 21 January 2012 were in exact agreement with SO2 concentrations measured at plume altitude on 1 February 2012.
Composite marginal quantile regression analysis for longitudinal adolescent body mass index data.
Yang, Chi-Chuan; Chen, Yi-Hau; Chang, Hsing-Yi
2017-09-20
Childhood and adolescenthood overweight or obesity, which may be quantified through the body mass index (BMI), is strongly associated with adult obesity and other health problems. Motivated by the child and adolescent behaviors in long-term evolution (CABLE) study, we are interested in individual, family, and school factors associated with marginal quantiles of longitudinal adolescent BMI values. We propose a new method for composite marginal quantile regression analysis for longitudinal outcome data, which performs marginal quantile regressions at multiple quantile levels simultaneously. The proposed method extends the quantile regression coefficient modeling method introduced by Frumento and Bottai (Biometrics 2016; 72:74-84) to longitudinal data accounting suitably for the correlation structure in longitudinal observations. A goodness-of-fit test for the proposed modeling is also developed. Simulation results show that the proposed method can be much more efficient than the analysis without taking correlation into account and the analysis performing separate quantile regressions at different quantile levels. The application to the longitudinal adolescent BMI data from the CABLE study demonstrates the practical utility of our proposal. Copyright © 2017 John Wiley & Sons, Ltd. Copyright © 2017 John Wiley & Sons, Ltd.
Litzenberg, Dale W; Gallagher, Ian; Masi, Kathryn J; Lee, Choonik; Prisciandaro, Joann I; Hamstra, Daniel A; Ritter, Timothy; Lam, Kwok L
2013-08-01
To present and characterize a measurement technique to quantify the calibration accuracy of an electromagnetic tracking system to radiation isocenter. This technique was developed as a quality assurance method for electromagnetic tracking systems used in a multi-institutional clinical hypofractionated prostate study. In this technique, the electromagnetic tracking system is calibrated to isocenter with the manufacturers recommended technique, using laser-based alignment. A test patient is created with a transponder at isocenter whose position is measured electromagnetically. Four portal images of the transponder are taken with collimator rotations of 45° 135°, 225°, and 315°, at each of four gantry angles (0°, 90°, 180°, 270°) using a 3×6 cm2 radiation field. In each image, the center of the copper-wrapped iron core of the transponder is determined. All measurements are made relative to this transponder position to remove gantry and imager sag effects. For each of the 16 images, the 50% collimation edges are identified and used to find a ray representing the rotational axis of each collimation edge. The 16 collimator rotation rays from four gantry angles pass through and bound the radiation isocenter volume. The center of the bounded region, relative to the transponder, is calculated and then transformed to tracking system coordinates using the transponder position, allowing the tracking system's calibration offset from radiation isocenter to be found. All image analysis and calculations are automated with inhouse software for user-independent accuracy. Three different tracking systems at two different sites were evaluated for this study. The magnitude of the calibration offset was always less than the manufacturer's stated accuracy of 0.2 cm using their standard clinical calibration procedure, and ranged from 0.014 to 0.175 cm. On three systems in clinical use, the magnitude of the offset was found to be 0.053±0.036, 0.121±0.023, and 0.093±0.013 cm. The method presented here provides an independent technique to verify the calibration of an electromagnetic tracking system to radiation isocenter. The calibration accuracy of the system was better than the 0.2 cm accuracy stated by the manufacturer. However, it should not be assumed to be zero, especially for stereotactic radiation therapy treatments where planning target volume margins are very small.
Margin adaptation of indirect composite inlays fabricated on flexible dies.
Price, R B; Gerrow, J D
2000-03-01
Indirect composite restorations can be made in 1 appointment using a flexible die. Interactions between different impression materials and flexible die materials may affect the accuracy of fit and margin adaptation of the restoration. This study compared the margin adaptation of composite inlays made using the following 5 impression/flexible die material combinations; condensation silicone/polyvinyl siloxane (CS/PVS), wash viscosity polyvinyl siloxane/medium or heavy viscosity polyvinyl siloxane (PVS/PVS), irreversible hydrocolloid impression/medium viscosity polyvinyl siloxane (IH/PVS), wash viscosity polyvinyl siloxane impression/polyether (PVS/PE), with composite inlays made using a control system of a wash viscosity polyvinyl siloxane impression and a type IV stone die. For each test and control system, 10 impressions were made of a class II composite inlay preparation in a metal master die. One die was made from each impression and one composite inlay was made and finished on each die (a total of 60 inlays). Inlays were placed on the master die and the margin opening at the buccal, distal, and gingival sites was recorded with a measuring microscope (x40 magnification). The overall mean +/- SD margin openings of inlays made from the systems were as follows: PVS wash/PVS heavy viscosity 149.5 +/- 107. 4 microm; PVS wash/PVS medium viscosity 87.4 +/- 63.0 microm; IH/PVS medium viscosity 76.7 +/- 48.9 microm; CS/PVS 73.3 +/- 48.7 microm, PVS wash viscosity/PE 64.0 +/- 44.3 microm, PVS wash viscosity/stone 53.9 +/- 48.3 microm. Composite inlays made using the PVS wash viscosity/PVS heavy viscosity system had significantly larger distal, gingival, and overall mean margin openings than all other inlays (ANOVA and Fisher PLSD test; P =.05). The separating medium required between some impression and die materials did not work consistently. Composite inlays fabricated on dies made of material different than the impression material had mean buccal, distal, gingival, and overall margin openings < or =100 microm. Composite inlays made on the CS/PVS, IH/PVS medium viscosity, PVS wash viscosity/PE flexible dies, and control PVS wash viscosity/stone dies had statistically similar (P =.05) mean buccal, distal, gingival, and overall mean margin openings that were < or =100 microm. Composite inlays made on dies that were made of the same type of material as the impression material (PVS/PVS) had mean gingival margin openings >100 microm that were significantly larger than all other systems tested (P =.05).
DOE Office of Scientific and Technical Information (OSTI.GOV)
NONE
1997-08-01
The emergence of competitive markets for electricity generation services is changing the way that electricity is and will be priced in the United States. This report presents the results of an analysis that focuses on two questions: (1) How are prices for competitive generation services likely to differ from regulated prices if competitive prices are based on marginal costs rather than regulated {open_quotes}cost-of-service{close_quotes} pricing? (2) What impacts will the competitive pricing of generation services (based on marginal costs) have on electricity consumption patterns, production costs, and the financial integrity patterns, production costs, and the financial integrity of electricity suppliers? Thismore » study is not intended to be a cost-benefit analysis of wholesale or retail competition, nor does this report include an analysis of the macroeconomic impacts of competitive electricity prices.« less
Comparison of a Traditional Probabilistic Risk Assessment Approach with Advanced Safety Analysis
DOE Office of Scientific and Technical Information (OSTI.GOV)
Smith, Curtis L; Mandelli, Diego; Zhegang Ma
2014-11-01
As part of the Light Water Sustainability Program (LWRS) [1], the purpose of the Risk Informed Safety Margin Characterization (RISMC) [2] Pathway research and development (R&D) is to support plant decisions for risk-informed margin management with the aim to improve economics, reliability, and sustain safety of current NPPs. In this paper, we describe the RISMC analysis process illustrating how mechanistic and probabilistic approaches are combined in order to estimate a safety margin. We use the scenario of a “station blackout” (SBO) wherein offsite power and onsite power is lost, thereby causing a challenge to plant safety systems. We describe themore » RISMC approach, illustrate the station blackout modeling, and contrast this with traditional risk analysis modeling for this type of accident scenario. We also describe our approach we are using to represent advanced flooding analysis.« less
Electricity Prices in a Competitive Environment: Marginal Cost Pricing
1997-01-01
Presents the results of an analysis that focuses on two questions: (1) How are prices for competitive generation services likely to differ from regulated prices if competitive prices are based on marginal costs rather than regulated cost-of-service pricing? (2) What impacts will the competitive pricing of generation services (based on marginal costs) have on electricity consumption patterns, production costs, and the financial integrity of electricity suppliers?
P.V., Ravichandra; Vemisetty, Harikumar; K., Deepthi; Reddy S, Jayaprada; D., Ramkiran; Krishna M., Jaya Nagendra; Malathi, Gita
2014-01-01
Aim: The purpose of this investigation was to evaluate the marginal adaptation of three root-end filling materials Glass ionomer cement, Mineral trioxide aggregate and BiodentineTM. Methodology: Thirty human single-rooted teeth were resected 3 mm from the apex. Root-end cavities were then prepared using an ultrasonic tip and filled with one of the following materials Glass ionomer cement (GIC), Mineral trioxide aggregate (MTA) and a bioactive cement BiodentineTM. The apical portions of the roots were then sectioned to obtain three 1 mm thick transversal sections. Confocal laser scanning microscopy (CLSM) was used to determine area of gaps and adaptation of the root-end filling materials with the dentin. The Post hoc test, a multiple comparison test was used for statistical data analysis. Results: Statistical analysis showed lowest marginal gaps (11143.42±967.753m2) and good marginal adaptation with BiodentineTM followed by MTA (22300.97±3068.883m2) and highest marginal gaps with GIC (33388.17±12155.903m2) which were statistically significant (p<0.0001). Conclusion: A new root end filling material BiodentineTM showed better marginal adaptation than commonly used root end filling materials PMID:24783148
Marginal and Random Intercepts Models for Longitudinal Binary Data With Examples From Criminology.
Long, Jeffrey D; Loeber, Rolf; Farrington, David P
2009-01-01
Two models for the analysis of longitudinal binary data are discussed: the marginal model and the random intercepts model. In contrast to the linear mixed model (LMM), the two models for binary data are not subsumed under a single hierarchical model. The marginal model provides group-level information whereas the random intercepts model provides individual-level information including information about heterogeneity of growth. It is shown how a type of numerical averaging can be used with the random intercepts model to obtain group-level information, thus approximating individual and marginal aspects of the LMM. The types of inferences associated with each model are illustrated with longitudinal criminal offending data based on N = 506 males followed over a 22-year period. Violent offending indexed by official records and self-report were analyzed, with the marginal model estimated using generalized estimating equations and the random intercepts model estimated using maximum likelihood. The results show that the numerical averaging based on the random intercepts can produce prediction curves almost identical to those obtained directly from the marginal model parameter estimates. The results provide a basis for contrasting the models and the estimation procedures and key features are discussed to aid in selecting a method for empirical analysis.
Power spectrum precision for redshift space distortions
NASA Astrophysics Data System (ADS)
Linder, Eric V.; Samsing, Johan
2013-02-01
Redshift space distortions in galaxy clustering offer a promising technique for probing the growth rate of structure and testing dark energy properties and gravity. We consider the issue of to what accuracy they need to be modeled in order not to unduly bias cosmological conclusions. Fitting for nonlinear and redshift space corrections to the linear theory real space density power spectrum in bins in wavemode, we analyze both the effect of marginalizing over these corrections and of the bias due to not correcting them fully. While naively subpercent accuracy is required to avoid bias in the unmarginalized case, in the fitting approach the Kwan-Lewis-Linder reconstruction function for redshift space distortions is found to be accurately selfcalibrated with little degradation in dark energy and gravity parameter estimation for a next generation galaxy redshift survey such as BigBOSS.
Sparse Bayesian Learning for Identifying Imaging Biomarkers in AD Prediction
Shen, Li; Qi, Yuan; Kim, Sungeun; Nho, Kwangsik; Wan, Jing; Risacher, Shannon L.; Saykin, Andrew J.
2010-01-01
We apply sparse Bayesian learning methods, automatic relevance determination (ARD) and predictive ARD (PARD), to Alzheimer’s disease (AD) classification to make accurate prediction and identify critical imaging markers relevant to AD at the same time. ARD is one of the most successful Bayesian feature selection methods. PARD is a powerful Bayesian feature selection method, and provides sparse models that is easy to interpret. PARD selects the model with the best estimate of the predictive performance instead of choosing the one with the largest marginal model likelihood. Comparative study with support vector machine (SVM) shows that ARD/PARD in general outperform SVM in terms of prediction accuracy. Additional comparison with surface-based general linear model (GLM) analysis shows that regions with strongest signals are identified by both GLM and ARD/PARD. While GLM P-map returns significant regions all over the cortex, ARD/PARD provide a small number of relevant and meaningful imaging markers with predictive power, including both cortical and subcortical measures. PMID:20879451
Shivasakthy, M; Asharaf Ali, Syed
2013-10-01
A new material is proposed in dentistry in the form of strips for producing gingival retraction. The clinical efficacy of the material remains untested. This study aimed to determine whether the polyvinyl acetate strips are able to effectively displace the gingival tissues in comparison with the conventional retraction cord. Complete metal ceramic preparation with supra-gingival margin was performed in fourteen maxillary incisors and gingival retraction was done using Merocel strips and conventional retraction cords alternatively in 2 weeks time interval. The amount of displacement was compared using a digital vernier caliper of 0.01mm accuracy. RESULTS were analyzed statistically using Paired students t-test. The statistical analysis of the data revealed that both the conventional retraction cord and the Merocel strip produce significant retraction. Among both the materials, Merocel proved to be significantly more effective. Merocel strip produces more gingival displacement than the conventional retraction cord.
Shivasakthy, M.; Asharaf Ali, Syed
2013-01-01
Statement of Problem: A new material is proposed in dentistry in the form of strips for producing gingival retraction. The clinical efficacy of the material remains untested. Purpose of the Study: This study aimed to determine whether the polyvinyl acetate strips are able to effectively displace the gingival tissues in comparison with the conventional retraction cord. Material and Methods: Complete metal ceramic preparation with supra-gingival margin was performed in fourteen maxillary incisors and gingival retraction was done using Merocel strips and conventional retraction cords alternatively in 2 weeks time interval. The amount of displacement was compared using a digital vernier caliper of 0.01mm accuracy. Results were analyzed statistically using Paired students t-test. Results: The statistical analysis of the data revealed that both the conventional retraction cord and the Merocel strip produce significant retraction. Among both the materials, Merocel proved to be significantly more effective. Conclusion: Merocel strip produces more gingival displacement than the conventional retraction cord. PMID:24298531
Visual cues and perceived reachability.
Gabbard, Carl; Ammar, Diala
2005-12-01
A rather consistent finding in studies of perceived (imagined) compared to actual movement in a reaching paradigm is the tendency to overestimate at midline. Explanations of such behavior have focused primarily on perceptions of postural constraints and the notion that individuals calibrate reachability in reference to multiple degrees of freedom, also known as the whole-body explanation. The present study examined the role of visual information in the form of binocular and monocular cues in perceived reachability. Right-handed participants judged the reachability of visual targets at midline with both eyes open, dominant eye occluded, and the non-dominant eye covered. Results indicated that participants were relatively accurate with condition responses not being significantly different in regard to total error. Analysis of the direction of error (mean bias) revealed effective accuracy across conditions with only a marginal distinction between monocular and binocular conditions. Therefore, within the task conditions of this experiment, it appears that binocular and monocular cues provide sufficient visual information for effective judgments of perceived reach at midline.
Jamming criticality revealed by removing localized buckling excitations.
Charbonneau, Patrick; Corwin, Eric I; Parisi, Giorgio; Zamponi, Francesco
2015-03-27
Recent theoretical advances offer an exact, first-principles theory of jamming criticality in infinite dimension as well as universal scaling relations between critical exponents in all dimensions. For packings of frictionless spheres near the jamming transition, these advances predict that nontrivial power-law exponents characterize the critical distribution of (i) small interparticle gaps and (ii) weak contact forces, both of which are crucial for mechanical stability. The scaling of the interparticle gaps is known to be constant in all spatial dimensions d-including the physically relevant d=2 and 3, but the value of the weak force exponent remains the object of debate and confusion. Here, we resolve this ambiguity by numerical simulations. We construct isostatic jammed packings with extremely high accuracy, and introduce a simple criterion to separate the contribution of particles that give rise to localized buckling excitations, i.e., bucklers, from the others. This analysis reveals the remarkable dimensional robustness of mean-field marginality and its associated criticality.
A unifying framework for marginalized random intercept models of correlated binary outcomes
Swihart, Bruce J.; Caffo, Brian S.; Crainiceanu, Ciprian M.
2013-01-01
We demonstrate that many current approaches for marginal modeling of correlated binary outcomes produce likelihoods that are equivalent to the copula-based models herein. These general copula models of underlying latent threshold random variables yield likelihood-based models for marginal fixed effects estimation and interpretation in the analysis of correlated binary data with exchangeable correlation structures. Moreover, we propose a nomenclature and set of model relationships that substantially elucidates the complex area of marginalized random intercept models for binary data. A diverse collection of didactic mathematical and numerical examples are given to illustrate concepts. PMID:25342871
Numerical analysis of tidal dynamics in the region around Gulf of Mannar and Palk Strait
NASA Astrophysics Data System (ADS)
Scaria, Sajumon; Murali, K.; Shanmugam, P.
2015-04-01
A 3D hydrodynamic model is presented to study tidal dynamics along the Indian coast and adjoining marginal seas as well as to investigate the volume transport of water across a tidal channel between the Gulf of Mannar and Palk Strait areas. The numerical model is validated in three stages, and its performance is further assessed by comparing the derived amplitudes of the semidiurnal and diurnal constituents with those of FES 2004 model. The accuracy of the model is ensured by comparing the tidal elevations at selected locations with the observed data. As a next level of validation, the elevations are subjected to the harmonic analysis in order to derive the harmonic constants. The numerical analysis of tidal energetics in the Palk Strait and Gulf of Mannar leads to conclude that M2 constituent undergoes more dissipation and the area-integrated mean dissipation rate of M2 and K1 is 3.22 and 0.25 GW. The temporal and spatial distributions of the sectional daily water volume transport are also analysed for the channel connecting the Palk Strait and the Gulf of Mannar. The localized geographical factors near the Adam's bridge area strongly influence the tidal flow, and the water volume transport shows seasonal variations.
NASA Astrophysics Data System (ADS)
Rabidas, Rinku; Midya, Abhishek; Chakraborty, Jayasree; Sadhu, Anup; Arif, Wasim
2018-02-01
In this paper, Curvelet based local attributes, Curvelet-Local configuration pattern (C-LCP), is introduced for the characterization of mammographic masses as benign or malignant. Amid different anomalies such as micro- calcification, bilateral asymmetry, architectural distortion, and masses, the reason for targeting the mass lesions is due to their variation in shape, size, and margin which makes the diagnosis a challenging task. Being efficient in classification, multi-resolution property of the Curvelet transform is exploited and local information is extracted from the coefficients of each subband using Local configuration pattern (LCP). The microscopic measures in concatenation with the local textural information provide more discriminating capability than individual. The measures embody the magnitude information along with the pixel-wise relationships among the neighboring pixels. The performance analysis is conducted with 200 mammograms of the DDSM database containing 100 mass cases of each benign and malignant. The optimal set of features is acquired via stepwise logistic regression method and the classification is carried out with Fisher linear discriminant analysis. The best area under the receiver operating characteristic curve and accuracy of 0.95 and 87.55% are achieved with the proposed method, which is further compared with some of the state-of-the-art competing methods.
Kim, Jae-Hyun; Jeong, Ji-Hye; Lee, Jin-Han; Cho, Hye-Won
2016-10-01
Although the number of lithium disilicate crowns fabricated with computer-aided design and computer-aided manufacturing (CAD-CAM) technology has increased, the accuracy of the prostheses produced by using digital pathways remains unknown. The purpose of this in vitro study was to compare marginal and internal discrepancies of lithium disilicate crowns fabricated from digital and conventional impressions. A typodont mandibular first molar was prepared for a lithium disilicate crown, and 20 duplicate dies were fabricated by milling poly(methyl methacrylate) resin blocks from laboratory scans. Four groups of 5 lithium disilicate crowns each were created by using a CS3500 (Carestream Dental) intraoral digital impression; Trios (3shape) intraoral digital impression; Ceramill Map400 (Amann Girrbach) extraoral digital impression; and a heat-press technique as a control group. All of the IPS e.max CAD (Ivoclar Vivadent AG) crowns were produced using a 5-axis milling engine (Ceramill Motion2). The lithium disilicate crowns were cemented with zinc phosphate cement under finger pressure. Marginal and internal discrepancies were measured using micro-computed tomography (SkyScan1172). One-way ANOVAs with the Tukey honest significant differences test were used for statistical analysis of the data (α=.05). The mean marginal discrepancies of CS3500 lithium disilicate crowns were 129.6 μm, 200.9 μm for Ceramill Map400, and 207.8 μm 176.1 μm for the heat-press technique; and the internal discrepancy volumes for CS3500 were 25.3 mm 3 , 40.7 mm 3 for Trios, 29.1 mm 3 for Ceramill Map400, and 29.1 and 31.4 mm 3 for the heat-press technique. The CS3500 group showed a significantly better marginal discrepancy than the other 3 groups and a smaller internal discrepancy volume than the Trios group (P<.05). Significant differences were found between IPS e.max CAD crowns produced using 2 intraoral digital impressions, whereas no differences were found between IPS e.max CAD crowns produced from an extraoral digital impression and IPS e.max Press crowns produced using a heat-press technique. Copyright © 2016 Editorial Council for the Journal of Prosthetic Dentistry. Published by Elsevier Inc. All rights reserved.
NASA Astrophysics Data System (ADS)
Zanello, Marc; Poulon, Fanny; Pallud, Johan; Varlet, Pascale; Hamzeh, H.; Abi Lahoud, Georges; Andreiuolo, Felipe; Ibrahim, Ali; Pages, Mélanie; Chretien, Fabrice; di Rocco, Federico; Dezamis, Edouard; Nataf, François; Turak, Baris; Devaux, Bertrand; Abi Haidar, Darine
2017-02-01
Delineating tumor margins as accurately as possible is of primordial importance in surgical oncology: extent of resection is associated with survival but respect of healthy surrounding tissue is necessary for preserved quality of life. The real-time analysis of the endogeneous fluorescence signal of brain tissues is a promising tool for defining margins of brain tumors. The present study aims to demonstrate the feasibility of multimodal optical analysis to discriminate fresh samples of gliomas, metastases and meningiomas from their appropriate controls. Tumor samples were studied on an optical fibered endoscope using spectral and fluorescence lifetime analysis and then on a multimodal set-up for acquiring spectral, one and two-photon fluorescence images, second harmonic generation signals and two-photon fluorescence lifetime datasets. The obtained data allowed us to differentiate healthy samples from tumor samples. These results confirmed the possible clinical relevance of this real-time multimodal optical analysis. This technique can be easily applied to neurosurgical procedures for a better delineation of surgical margins.
Money well spent: a comparison of hospital operating margin for laparoscopic and open colectomies.
Koopmann, M C; Harms, B A; Heise, C P
2007-10-01
Cost analysis after laparoscopic colectomy has been examined, although reports evaluating the effects of laparoscopy on hospital operating margin are lacking. We compared several cost/revenue measures, including hospital operating margin, between open and laparoscopic colectomies at an academic center. Our cost-accounting database was queried for laparoscopic partial (LPC) and total colectomies (LTC), and open partial (OPC) and total colectomies (OTC) to analyze net revenue, total costs, and total hospital operating margin over a 4-year period. Laparoscopic and open colectomy cases were compared, with mean operating margin as the primary outcome. From July, 2002 through May, 2006, 842 patients were included for analysis with 138 undergoing laparoscopic colectomy. Net revenue was higher in the LTC group compared with open (US dollars 30,300 vs US dollars 26,800 [P = .02]), and lower in the LPC group (US dollars 15,300 vs US dollars 21,300 open [P < .0001]). Total costs were reduced in both the LPC and LTC groups compared with open [US dollars 11,700 vs US dollars 17,600 [P < .0001] and US dollars 18,000 vs US dollars 19,400 [P = .0019], respectively). LPC resulted in a similar HOM (US dollars 3,602) compared with OPC (US dollars 3,647; P = .35). LTC resulted in a higher HOM (US dollars 12,300) compared with OTC (US dollars 7,400; P = .02). LTC generates a significantly higher hospital operating margin than an OTC, although the margins are similar for LPC and OPC.
Preisser, John S; Long, D Leann; Stamm, John W
2017-01-01
Marginalized zero-inflated count regression models have recently been introduced for the statistical analysis of dental caries indices and other zero-inflated count data as alternatives to traditional zero-inflated and hurdle models. Unlike the standard approaches, the marginalized models directly estimate overall exposure or treatment effects by relating covariates to the marginal mean count. This article discusses model interpretation and model class choice according to the research question being addressed in caries research. Two data sets, one consisting of fictional dmft counts in 2 groups and the other on DMFS among schoolchildren from a randomized clinical trial comparing 3 toothpaste formulations to prevent incident dental caries, are analyzed with negative binomial hurdle, zero-inflated negative binomial, and marginalized zero-inflated negative binomial models. In the first example, estimates of treatment effects vary according to the type of incidence rate ratio (IRR) estimated by the model. Estimates of IRRs in the analysis of the randomized clinical trial were similar despite their distinctive interpretations. The choice of statistical model class should match the study's purpose, while accounting for the broad decline in children's caries experience, such that dmft and DMFS indices more frequently generate zero counts. Marginalized (marginal mean) models for zero-inflated count data should be considered for direct assessment of exposure effects on the marginal mean dental caries count in the presence of high frequencies of zero counts. © 2017 S. Karger AG, Basel.
Preisser, John S.; Long, D. Leann; Stamm, John W.
2017-01-01
Marginalized zero-inflated count regression models have recently been introduced for the statistical analysis of dental caries indices and other zero-inflated count data as alternatives to traditional zero-inflated and hurdle models. Unlike the standard approaches, the marginalized models directly estimate overall exposure or treatment effects by relating covariates to the marginal mean count. This article discusses model interpretation and model class choice according to the research question being addressed in caries research. Two datasets, one consisting of fictional dmft counts in two groups and the other on DMFS among schoolchildren from a randomized clinical trial (RCT) comparing three toothpaste formulations to prevent incident dental caries, are analysed with negative binomial hurdle (NBH), zero-inflated negative binomial (ZINB), and marginalized zero-inflated negative binomial (MZINB) models. In the first example, estimates of treatment effects vary according to the type of incidence rate ratio (IRR) estimated by the model. Estimates of IRRs in the analysis of the RCT were similar despite their distinctive interpretations. Choice of statistical model class should match the study’s purpose, while accounting for the broad decline in children’s caries experience, such that dmft and DMFS indices more frequently generate zero counts. Marginalized (marginal mean) models for zero-inflated count data should be considered for direct assessment of exposure effects on the marginal mean dental caries count in the presence of high frequencies of zero counts. PMID:28291962
DOT National Transportation Integrated Search
2013-01-01
This software can be used to assist with the assessment of margin of safety for a horizontal curve. It is intended for use by engineers and technicians responsible for safety analysis or management of rural highway pavement or traffic control devices...
77 FR 41109 - Margin Requirements for Uncleared Swaps for Swap Dealers and Major Swap Participants
Federal Register 2010, 2011, 2012, 2013, 2014
2012-07-12
... and specifically requests quantitative data and analysis on the comparative costs and benefits of the... quantitative impact study (``QIS'') to assess the costs and benefits of margin requirements. The results of the...
NASA Astrophysics Data System (ADS)
George, Rohini
Lung cancer accounts for 13% of all cancers in the Unites States and is the leading cause of deaths among both men and women. The five-year survival for lung cancer patients is approximately 15%.(ACS facts & figures) Respiratory motion decreases accuracy of thoracic radiotherapy during imaging and delivery. To account for respiration, generally margins are added during radiation treatment planning, which may cause a substantial dose delivery to normal tissues and increase the normal tissue toxicity. To alleviate the above-mentioned effects of respiratory motion, several motion management techniques are available which can reduce the doses to normal tissues, thereby reducing treatment toxicity and allowing dose escalation to the tumor. This may increase the survival probability of patients who have lung cancer and are receiving radiation therapy. However the accuracy of these motion management techniques are inhibited by respiration irregularity. The rationale of this thesis was to study the improvement in regularity of respiratory motion by breathing coaching for lung cancer patients using audio instructions and audio-visual biofeedback. A total of 331 patient respiratory motion traces, each four minutes in length, were collected from 24 lung cancer patients enrolled in an IRB-approved breathing-training protocol. It was determined that audio-visual biofeedback significantly improved the regularity of respiratory motion compared to free breathing and audio instruction, thus improving the accuracy of respiratory gated radiotherapy. It was also observed that duty cycles below 30% showed insignificant reduction in residual motion while above 50% there was a sharp increase in residual motion. The reproducibility of exhale based gating was higher than that of inhale base gating. Modeling the respiratory cycles it was found that cosine and cosine 4 models had the best correlation with individual respiratory cycles. The overall respiratory motion probability distribution function could be approximated to a normal distribution function. A statistical analysis was also performed to investigate if a patient's physical, tumor or general characteristics played a role in identifying whether he/she responded positively to the coaching type---signified by a reduction in the variability of respiratory motion. The analysis demonstrated that, although there were some characteristics like disease type and dose per fraction that were significant with respect to time-independent analysis, there were no significant time trends observed for the inter-session or intra-session analysis. Based on patient feedback with the existing audio-visual biofeedback system used for the study and research performed on other feedback systems, an improved audio-visual biofeedback system was designed. It is hoped the widespread clinical implementation of audio-visual biofeedback for radiotherapy will improve the accuracy of lung cancer radiotherapy.
Mac Kinnon, Michael; Heydarzadeh, Zahra; Doan, Quy; Ngo, Cuong; Reed, Jeff; Brouwer, Jacob
2018-05-17
Accurate quantification of methane emissions from the natural gas system is important for establishing greenhouse gas inventories and understanding cause and effect for reducing emissions. Current carbon intensity methods generally assume methane emissions are proportional to gas throughput so that increases in gas consumption yield linear increases in emitted methane. However, emissions sources are diverse and many are not proportional to throughput. Insights into the causal drivers of system methane emissions, and how system-wide changes affect such drivers are required. The development of a novel cause-based methodology to assess marginal methane emissions per unit of fuel consumed is introduced. The carbon intensities of technologies consuming natural gas are critical metrics currently used in policy decisions for reaching environmental goals. For example, the low-carbon fuel standard in California uses carbon intensity to determine incentives provided. Current methods generally assume methane emissions from the natural gas system are completely proportional to throughput. The proposed cause-based marginal emissions method will provide a better understanding of the actual drivers of emissions to support development of more effective mitigation measures. Additionally, increasing the accuracy of carbon intensity calculations supports the development of policies that can maximize the environmental benefits of alternative fuels, including reducing greenhouse gas emissions.
NASA Astrophysics Data System (ADS)
Samkoe, Kimberley S.; Bates, Brent D.; Tselepidakis, Niki N.; DSouza, Alisha V.; Gunn, Jason R.; Ramkumar, Dipak B.; Paulsen, Keith D.; Pogue, Brian W.; Henderson, Eric R.
2017-12-01
Wide local excision (WLE) of tumors with negative margins remains a challenge because surgeons cannot directly visualize the mass. Fluorescence-guided surgery (FGS) may improve surgical accuracy; however, conventional methods with direct surface tumor visualization are not immediately applicable, and properties of tissues surrounding the cancer must be considered. We developed a phantom model for sarcoma resection with the near-infrared fluorophore IRDye 800CW and used it to iteratively define the properties of connective tissues that typically surround sarcoma tumors. We then tested the ability of a blinded surgeon to resect fluorescent tumor-simulating inclusions with ˜1-cm margins using predetermined target fluorescence intensities and a Solaris open-air fluorescence imaging system. In connective tissue-simulating phantoms, fluorescence intensity decreased with increasing blood concentration and increased with increasing intralipid concentrations. Fluorescent inclusions could be resolved at ≥1-cm depth in all inclusion concentrations and sizes tested. When inclusion depth was held constant, fluorescence intensity decreased with decreasing volume. Using targeted fluorescence intensities, a blinded surgeon was able to successfully excise inclusions with ˜1-cm margins from fat- and muscle-simulating phantoms with inclusion-to-background contrast ratios as low as 2∶1. Indirect, subsurface FGS is a promising tool for surgical resection of cancers requiring WLE.
Automated detection of a prostate Ni-Ti stent in electronic portal images.
Carl, Jesper; Nielsen, Henning; Nielsen, Jane; Lund, Bente; Larsen, Erik Hoejkjaer
2006-12-01
Planning target volumes (PTV) in fractionated radiotherapy still have to be outlined with wide margins to the clinical target volume due to uncertainties arising from daily shift of the prostate position. A recently proposed new method of visualization of the prostate is based on insertion of a thermo-expandable Ni-Ti stent. The current study proposes a new detection algorithm for automated detection of the Ni-Ti stent in electronic portal images. The algorithm is based on the Ni-Ti stent having a cylindrical shape with a fixed diameter, which was used as the basis for an automated detection algorithm. The automated method uses enhancement of lines combined with a grayscale morphology operation that looks for enhanced pixels separated with a distance similar to the diameter of the stent. The images in this study are all from prostate cancer patients treated with radiotherapy in a previous study. Images of a stent inserted in a humanoid phantom demonstrated a localization accuracy of 0.4-0.7 mm which equals the pixel size in the image. The automated detection of the stent was compared to manual detection in 71 pairs of orthogonal images taken in nine patients. The algorithm was successful in 67 of 71 pairs of images. The method is fast, has a high success rate, good accuracy, and has a potential for unsupervised localization of the prostate before radiotherapy, which would enable automated repositioning before treatment and allow for the use of very tight PTV margins.
Minervini, Andrea; Campi, Riccardo; Kutikov, Alexander; Montagnani, Ilaria; Sessa, Francesco; Serni, Sergio; Raspollini, Maria Rosaria; Carini, Marco
2015-10-01
The surface-intermediate-base margin score is a novel standardized reporting system of resection techniques during nephron sparing surgery. We validated the surgeon assessed surface-intermediate-base score with microscopic histopathological assessment of partial nephrectomy specimens. Between June and August 2014 data were prospectively collected from 40 consecutive patients undergoing nephron sparing surgery. The surface-intermediate-base score was assigned to all cases. The score specific areas were color coded with tissue margin ink and sectioned for histological evaluation of healthy renal margin thickness. Maximum, minimum and mean thickness of healthy renal margin for each score specific area grade (surface [S] = 0, S = 1 ; intermediate [I] or base [B] = 0, I or B = 1, I or B = 2) was reported. The Mann-Whitney U and Kruskal-Wallis tests were used to compare the thickness of healthy renal margin in S = 0 vs 1 and I or B = 0 vs 1 vs 2 grades, respectively. Maximum, minimum and mean thickness of healthy renal margin was significantly different among score specific area grades S = 0 vs 1, and I or B = 0 vs 1, 0 vs 2 and 1 vs 2 (p <0.001). The main limitations of the study are the low number of the I or B = 1 and I or B = 2 samples and the assumption that each microscopic slide reflects the entire score specific area for histological analysis. The surface-intermediate-base scoring method can be readily harnessed in real-world clinical practice and accurately mirrors histopathological analysis for quantification and reporting of healthy renal margin thickness removed during tumor excision. Copyright © 2015 American Urological Association Education and Research, Inc. Published by Elsevier Inc. All rights reserved.
NASA Astrophysics Data System (ADS)
Cadenas, P.; Fernández-Viejo, G.; Pulgar, J. A.; Tugend, J.; Manatschal, G.; Minshull, T. A.
2018-03-01
The Alpine Pyrenean-Cantabrian orogen developed along the plate boundary between Iberia and Europe, involving the inversion of Mesozoic hyperextended basins along the southern Biscay margin. Thus, this margin represents a natural laboratory to analyze the control of structural rift inheritance on the compressional reactivation of a continental margin. With the aim to identify former rift domains and investigate their role during the subsequent compression, we performed a structural analysis of the central and western North Iberian margin, based on the interpretation of seismic reflection profiles and local constraints from drill-hole data. Seismic interpretations and published seismic velocity models enabled the development of crustal thickness maps that helped to constrain further the offshore and onshore segmentation. Based on all these constraints, we present a rift domain map across the central and western North Iberian margin, as far as the adjacent western Cantabrian Mountains. Furthermore, we provide a first-order description of the margin segmentation resulting from its polyphase tectonic evolution. The most striking result is the presence of a hyperthinned domain (e.g., Asturian Basin) along the central continental platform that is bounded to the north by the Le Danois High, interpreted as a rift-related continental block separating two distinctive hyperextended domains. From the analysis of the rift domain map and the distribution of reactivation structures, we conclude that the landward limit of the necking domain and the hyperextended domains, respectively, guide and localize the compressional overprint. The Le Danois block acted as a local buttress, conditioning the inversion of the Asturian Basin.
Soliman, Sebastian; Preidl, Reinhard; Karl, Sabine; Hofmann, Norbert; Krastl, Gabriel; Klaiber, Bernd
2016-01-01
To investigate the influence of three cavity designs on the marginal seal of large Class II cavities restored with low-shrinkage resin composite limited to the enamel. One hundred twenty (120) intact human molars were randomly divided into 12 groups, with three different cavity designs: 1. undermined enamel, 2. box-shaped, and 3. proximal bevel. The teeth were restored with 1. an extra-low shrinkage (ELS) composite free of diluent monomers, 2. microhybrid composite (Herculite XRV), 3. nanohybrid composite (Filtek Supreme XTE), and 4. silorane-based composite (Filtek Silorane). After artificial aging by thermocycling and storage in physiological saline, epoxy resin replicas were prepared. To determine the integrity of the restorations' approximal margins, two methods were sequentially employed: 1. replicas were made of the 120 specimens and examined using SEM, and 2. the same 120 specimens were immersed in AgNO3 solution, and the dye penetration depth was observed with a light microscope. Statistical analysis was performed using the Kruskal-Wallis and the Dunn-Bonferroni tests. After bevel preparation, SEM observations showed that restorations did not exhibit a higher percentage of continuous margin (SEM-analysis; p>0.05), but more leakage was found than with the other cavity designs (p<0.05). The lowest percentage of continuous margin was observed in ELS restorations (p<0.05). More fractured margins were observed in the undermined enamel cavity design groups (p<0.05). Bevel preparation failed to improve margin quality in large Class II composite restorations and is no longer recommended. However, undermined enamel should be removed to prevent enamel fractures.
Zhang, X Y; Li, H; Zhao, Y J; Wang, Y; Sun, Y C
2016-07-01
To quantitatively evaluate the quality and accuracy of three-dimensional (3D) data acquired by using two kinds of structure intra-oral scanner to scan the typical teeth crown preparations. Eight typical teeth crown preparations model were scanned 3 times with two kinds of structured light intra-oral scanner(A, B), as test group. A high precision model scanner were used to scan the model as true value group. The data above the cervical margin was extracted. The indexes of quality including non-manifold edges, the self-intersections, highly-creased edges, spikes, small components, small tunnels, small holes and the anount of triangles were measured with the tool of mesh doctor in Geomagic studio 2012. The scanned data of test group were aligned to the data of true value group. 3D deviations of the test group compared with true value group were measured for each scanned point, each preparation and each group. Independent-samples Mann-Whitney U test was applied to analyze 3D deviations for each scanned point of A and B group. Correlation analysis was applied to index values and 3D deviation values. The total number of spikes in A group was 96, and that in B group and true value group were 5 and 0 respectively. Trueness: A group 8.0 (8.3) μm, B group 9.5 (11.5) μm(P>0.05). Correlation analysis of the number of spikes with data precision of A group was r=0.46. In the study, the qulity of the scanner B is better than scanner A, the difference of accuracy is not statistically significant. There is correlation between quality and data precision of the data scanned with scanner A.
Fariña-Sarasqueta, Arantza; de Haan, Lorraine M.; Eggermont, Jeroen; Bonsing, Bert A.; Morreau, Hans; Lelieveldt, Boudewijn P. F.; van de Velde, Cornelis J. H.; Vahrmeijer, Alexander L.; Dijkstra, Jouke
2017-01-01
Background Pancreatic cancer is the fourth leading cause of cancer-related mortality in the United States. The minority of patients can undergo curative-intended surgical therapy due to progressive disease stage at time of diagnosis. Nonetheless, tumor involvement of surgical margins is seen in up to 70% of resections, being a strong negative prognostic factor. Real-time intraoperative imaging modalities may aid surgeons to obtain tumor-free resection margins. Full-field optical coherence tomography (FF-OCT) is a promising diagnostic tool using high-resolution white-light interference microscopy without tissue processing. Therefore, we composed an atlas of FF-OCT images of malignant and benign pancreatic tissue, and investigated the accuracy with which the pathologists could distinguish these. Materials and methods One hundred FF-OCT images were collected from specimens of 29 patients who underwent pancreatic resection for various indications between 2014 and 2016. One experienced gastrointestinal pathologist and one pathologist in training scored independently the FF-OCT images as malignant or benign blinded to the final pathology conclusion. Results were compared to those obtained with standard hematoxylin and eosin (H&E) slides. Results Overall, combined test characteristics of both pathologists showed a sensitivity of 72%, specificity of 74%, positive predictive value of 69%, negative predictive value of 79% and an overall accuracy of 73%. In the subset of pancreatic ductal adenocarcinoma patients, 97% of the FF-OCT images (n = 35) were interpreted as tumor by at least one pathologist. Moreover, normal pancreatic tissue was recognised in all cases by at least one pathologist. However, atrophy and fibrosis, serous cystadenoma and neuroendocrine tumors were more often wrongly scored, in 63%, 100% and 25% respectively. Conclusion FF-OCT could distinguish normal pancreatic tissue from pathologic pancreatic tissue in both processed as non-processed specimens using architectural features. The accuracy in pancreatic ductal adenocarcinoma is promising and warrants further evaluation using improved assessment criteria. PMID:28414765
Navigation system for minimally invasive esophagectomy: experimental study in a porcine model.
Nickel, Felix; Kenngott, Hannes G; Neuhaus, Jochen; Sommer, Christof M; Gehrig, Tobias; Kolb, Armin; Gondan, Matthias; Radeleff, Boris A; Schaible, Anja; Meinzer, Hans-Peter; Gutt, Carsten N; Müller-Stich, Beat-Peter
2013-10-01
Navigation systems potentially facilitate minimally invasive esophagectomy and improve patient outcome by improving intraoperative orientation, position estimation of instruments, and identification of lymph nodes and resection margins. The authors' self-developed navigation system is highly accurate in static environments. This study aimed to test the overall accuracy of the navigation system in a realistic operating room scenario and to identify the different sources of error altering accuracy. To simulate a realistic environment, a porcine model (n = 5) was used with endoscopic clips in the esophagus as navigation targets. Computed tomography imaging was followed by image segmentation and target definition with the medical imaging interaction toolkit software. Optical tracking was used for registration and localization of animals and navigation instruments. Intraoperatively, the instrument was displayed relative to segmented organs in real time. The target registration error (TRE) of the navigation system was defined as the distance between the target and the navigation instrument tip. The TRE was measured on skin targets with the animal in the 0° supine and 25° anti-Trendelenburg position and on the esophagus during laparoscopic transhiatal preparation. On skin targets, the TRE was significantly higher in the 25° position, at 14.6 ± 2.7 mm, compared with the 0° position, at 3.2 ± 1.3 mm. The TRE on the esophagus was 11.2 ± 2.4 mm. The main source of error was soft tissue deformation caused by intraoperative positioning, pneumoperitoneum, surgical manipulation, and tissue dissection. The navigation system obtained acceptable accuracy with a minimally invasive transhiatal approach to the esophagus in a realistic experimental model. Thus the system has the potential to improve intraoperative orientation, identification of lymph nodes and adequate resection margins, and visualization of risk structures. Compensation methods for soft tissue deformation may lead to an even more accurate navigation system in the future.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Morton, Daniel; Batchelar, Deidre; Hilts, Michelle
Purpose: Uncertainties in target identification can reduce treatment accuracy in permanent breast seed implant (PBSI) brachytherapy. This study evaluates the relationship between seroma visualization and seed placement accuracy. Methods: Spatially co-registered CT and 3D ultrasound (US) images were acquired for 10 patients receiving PBSI. Seromas were retrospectively contoured independently by 3 radiation oncologists on both CT and US and respective consensus volumes were defined, CTV{sub CT} and CTV{sub US}. The seroma clarity and inter-user conformity index (CI), as well as inter-modality CI, volume, and positional differences were evaluated. Correlations with seed placement accuracy were then assessed. CTVs were expanded bymore » 1.25cm to create PTV{sub CT} and PTV{sub US} and evaluate the conformity with PTV{sub Clinical} (CTV{sub Clinical}+1.25cm) used in treatment planning. The change in PTV coincidence by expanding PTV{sub Clinical} by 0.25cm was determined. Results: CTV{sub US} were a mean 68 ± 12% smaller than CTV{sub CT} and generally had improved clarity and inter-user conformity. No correlations between seed displacement and CTV{sub US}-CTV{sub CT} positional difference or CI were observed. Greater seed displacements were associated with larger CTV{sub US}-CTV{sub CT} volume differences (r=−0.65) and inter-user CT CI (r=−0.74). A median (range) 88% (71–99%) of PTV{sub CT} and 83% (69–100%) of PTV{sub US} were contained within PTV{sub Clinical}. Expanding treatment margins to 1.5cm increased coincidence to 98% (86–100%) and 94% (82–100%), respectively. Conclusions: Differences in seroma visualization impacts seed displacement in PBSI. Reducing dependence on CT by incorporating 3DUS into target identification, or expanding CT-based treatment margins to 1.5cm may reduce or mitigate uncertainties related to seroma visualization.« less
Presotto, Anna Gabriella Camacho; Bhering, Cláudia Lopes Brilhante; Mesquita, Marcelo Ferraz; Barão, Valentim Adelino Ricardo
2017-03-01
Several studies have shown the superiority of computer-assisted design and computer-assisted manufacturing (CAD-CAM) technology compared with conventional casting. However, an advanced technology exists for casting procedures (the overcasting technique), which may serve as an acceptable and affordable alternative to CAD-CAM technology for fabricating 3-unit implant-supported fixed dental prostheses (FDPs). The purpose of this in vitro study was to evaluate, using quantitative photoelastic analysis, the effect of the prosthetic framework fabrication method (CAD-CAM and overcasting) on the marginal fit and stress transmitted to implants. The correlation between marginal fit and stress was also investigated. Three-unit implant-supported FDP frameworks were made using the CAD-CAM (n=10) and overcasting (n=10) methods. The frameworks were waxed to simulate a mandibular first premolar (PM region) to first molar (M region) FDP using overcast mini-abutment cylinders. The wax patterns were overcast (overcast experimental group) or scanned to obtain the frameworks (CAD-CAM control group). All frameworks were fabricated from cobalt-chromium (CoCr) alloy. The marginal fit was analyzed according to the single-screw test protocol, obtaining an average value for each region (M and PM) and each framework. The frameworks were tightened for the photoelastic model with standardized 10-Ncm torque. Stress was measured by quantitative photoelastic analysis. The results were submitted to the Student t test, 2-way ANOVA, and Pearson correlation test (α=.05). The framework fabrication method (FM) and evaluation site (ES; M and PM regions) did not affect the marginal fit values (P=.559 for FM and P=.065 for ES) and stress (P=.685 for FM and P=.468 for ES) in the implant-supported system. Positive correlations between marginal fit and stress were observed (CAD-CAM: r=0.922; P<.001; overcast: r=0.908; P<.001). CAD-CAM and overcasting methods present similar marginal fit and stress values for 3-unit FDP frameworks. The decreased marginal fit of frameworks induces greater stress in the implant-supported system. Copyright © 2016 Editorial Council for the Journal of Prosthetic Dentistry. Published by Elsevier Inc. All rights reserved.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Choi, Clara Y.H.; Chang, Steven D.; Gibbs, Iris C.
2012-10-01
Purpose: Given the neurocognitive toxicity associated with whole-brain irradiation (WBRT), approaches to defer or avoid WBRT after surgical resection of brain metastases are desirable. Our initial experience with stereotactic radiosurgery (SRS) targeting the resection cavity showed promising results. We examined the outcomes of postoperative resection cavity SRS to determine the effect of adding a 2-mm margin around the resection cavity on local failure (LF) and toxicity. Patients and Methods: We retrospectively evaluated 120 cavities in 112 patients treated from 1998-2009. Factors associated with LF and distant brain failure (DF) were analyzed using competing risks analysis, with death as a competingmore » risk. The overall survival (OS) rate was calculated by the Kaplan-Meier product-limit method; variables associated with OS were evaluated using the Cox proportional hazards and log rank tests. Results: The 12-month cumulative incidence rates of LF and DF, with death as a competing risk, were 9.5% and 54%, respectively. On univariate analysis, expansion of the cavity with a 2-mm margin was associated with decreased LF; the 12-month cumulative incidence rates of LF with and without margin were 3% and 16%, respectively (P=.042). The 12-month toxicity rates with and without margin were 3% and 8%, respectively (P=.27). On multivariate analysis, melanoma histology (P=.038) and number of brain metastases (P=.0097) were associated with higher DF. The median OS time was 17 months (range, 2-114 months), with a 12-month OS rate of 62%. Overall, WBRT was avoided in 72% of the patients. Conclusion: Adjuvant SRS targeting the resection cavity of brain metastases results in excellent local control and allows WBRT to be avoided in a majority of patients. A 2-mm margin around the resection cavity improved local control without increasing toxicity compared with our prior technique with no margin.« less
Cervical and Incisal Marginal Discrepancy in Ceramic Laminate Veneering Materials: A SEM Analysis.
Ranganathan, Hemalatha; Ganapathy, Dhanraj M; Jain, Ashish R
2017-01-01
Marginal discrepancy influenced by the choice of processing material used for the ceramic laminate veneers needs to be explored further for better clinical application. This study aimed to evaluate the amount of cervical and incisal marginal discrepancy associated with different ceramic laminate veneering materials. This was an experimental, single-blinded, in vitro trial. Ten central incisors were prepared for laminate veneers with 2 mm uniform reduction and heavy chamfer finish line. Ceramic laminate veneers fabricated over the prepared teeth using four different processing materials were categorized into four groups as Group I - aluminous porcelain veneers, Group II - lithium disilicate ceramic veneers, Group III - lithium disilicate-leucite-based veneers, Group IV - zirconia-based ceramic veneers. The cervical and incisal marginal discrepancy was measured using a scanning electron microscope. ANOVA and post hoc Tukey honest significant difference (HSD) tests were used for statistical analysis. The cervical and incisal marginal discrepancy for four groups was Group I - 114.6 ± 4.3 μm, 132.5 ± 6.5 μm, Group II - 86.1 ± 6.3 μm, 105.4 ± 5.3 μm, Group III - 71.4 ± 4.4 μm, 91.3 ± 4.7 μm, and Group IV - 123.1 ± 4.1 μm, 142.0 ± 5.4 μm. ANOVA and post hoc Tukey HSD tests observed a statistically significant difference between the four test specimens with regard to cervical marginal discrepancy. The cervical and incisal marginal discrepancy scored F = 243.408, P < 0.001 and F = 180.844, P < 0.001, respectively. This study concluded veneers fabricated using leucite reinforced lithium disilicate exhibited the least marginal discrepancy followed by lithium disilicate ceramic, aluminous porcelain, and zirconia-based ceramics. The marginal discrepancy was more in the incisal region than in the cervical region in all the groups.
Comparison of hydrothermal activity between the Adriatic and the Red Sea rift margins
NASA Astrophysics Data System (ADS)
Ball, Philip; Incerpi, Nicolò; Birkle, Peter; Lacsamana, Elizabeth; Manatschal, Gianreto; Agar, Susan; Zhang, Shuo; Borsato, Ron
2017-04-01
Detailed field studies, and access to high-quality seismic reflection and refraction data have led to an improved understanding of the architecture and evolution of magma poor and magma rich margins. Associated with the spatial-temporal evolution of the rift, it is evident that there are evolving, extensive, fluid-rock interactions due to the infiltration of fluids within the sediment, basement and lithospheric mantle. Key questions therefore arise: What are the different fluid-rock reactions that can be typed to different geodynamic stages of the rift evolution? What are their compositions and how do they interact with their environment (basement, sediments, evaporites, hydrosphere, and magmatism)? What are the implications for the evolution of the margin rheology, thermal structure, depositional environments/organic matter maturity, and reservoir quality? The Adriatic paleo-rifted margin is preserved in both SE Switzerland and northern Italy. The field exposures provide a unique opportunity to study the fluid flow history of a hyperextended magma poor extensional margin. Analysis of breccias, cement veins and replacement minerals reveal that the margin records a complex, long-lasting history of dolomitization, calcification and silicification during the Jurassic rifting. The Red Sea by contrast is a young rifted margin. It differs from the paleo-Adriatic margin by several characteristics: volcanism is more evident, and syn-tectonic sediments, including evaporites (halite and anhydrite) are thicker. Several core and fluid samples are available from both onshore and offshore wells, which reveal rift-related hydrothermal alteration. In addition, we find evidence for the presence of an extreme dynamic hydraulic system with infiltration of surface water into sub-salt units during Late Pleistocene. In this study we present results from petrographic and geochemical analysis of basement and sedimentary rocks from Adriatic field-derived samples and core/subsurface fluid samples for the Eastern Red Sea margin. The results are presented using rift domain interpretations, thereby enabling the simple comparison of the observed hydrothermal alteration within a first-order (spatial temporal) rift geodynamic framework.
Huo, Yinghe; Vincken, Koen L; van der Heijde, Desiree; de Hair, Maria J H; Lafeber, Floris P; Viergever, Max A
2017-11-01
Objective: Wrist joint space narrowing is a main radiographic outcome of rheumatoid arthritis (RA). Yet, automatic radiographic wrist joint space width (JSW) quantification for RA patients has not been widely investigated. The aim of this paper is to present an automatic method to quantify the JSW of three wrist joints that are least affected by bone overlapping and are frequently involved in RA. These joints are located around the scaphoid bone, viz. the multangular-navicular, capitate-navicular-lunate, and radiocarpal joints. Methods: The joint space around the scaphoid bone is detected by using consecutive searches of separate path segments, where each segment location aids in constraining the subsequent one. For joint margin delineation, first the boundary not affected by X-ray projection is extracted, followed by a backtrace process to obtain the actual joint margin. The accuracy of the quantified JSW is evaluated by comparison with the manually obtained ground truth. Results: Two of the 50 radiographs used for evaluation of the method did not yield a correct path through all three wrist joints. The delineated joint margins of the remaining 48 radiographs were used for JSW quantification. It was found that 90% of the joints had a JSW deviating less than 20% from the mean JSW of manual indications, with the mean JSW error less than 10%. Conclusion: The proposed method is able to automatically quantify the JSW of radiographic wrist joints reliably. The proposed method may aid clinical researchers to study the progression of wrist joint damage in RA studies. Objective: Wrist joint space narrowing is a main radiographic outcome of rheumatoid arthritis (RA). Yet, automatic radiographic wrist joint space width (JSW) quantification for RA patients has not been widely investigated. The aim of this paper is to present an automatic method to quantify the JSW of three wrist joints that are least affected by bone overlapping and are frequently involved in RA. These joints are located around the scaphoid bone, viz. the multangular-navicular, capitate-navicular-lunate, and radiocarpal joints. Methods: The joint space around the scaphoid bone is detected by using consecutive searches of separate path segments, where each segment location aids in constraining the subsequent one. For joint margin delineation, first the boundary not affected by X-ray projection is extracted, followed by a backtrace process to obtain the actual joint margin. The accuracy of the quantified JSW is evaluated by comparison with the manually obtained ground truth. Results: Two of the 50 radiographs used for evaluation of the method did not yield a correct path through all three wrist joints. The delineated joint margins of the remaining 48 radiographs were used for JSW quantification. It was found that 90% of the joints had a JSW deviating less than 20% from the mean JSW of manual indications, with the mean JSW error less than 10%. Conclusion: The proposed method is able to automatically quantify the JSW of radiographic wrist joints reliably. The proposed method may aid clinical researchers to study the progression of wrist joint damage in RA studies.
A comparison between three different pit and fissure sealants with regard to marginal integrity.
Fernandes, Kristlee Sabrin; Chalakkal, Paul; de Ataide, Ida de Noronha; Pavaskar, Rajdeep; Fernandes, Precylia Philo; Soni, Harleen
2012-04-01
THE AIM OF THIS STUDY IS TO COMPARE THE OCCURRENCE OF ENAMEL FRACTURES, SEALANT FRACTURES AND MARGINAL FISSURES AFTER PLACEMENT OF THREE SEALANTS: Helioseal F, Conseal F and Clinpro. Thirty individuals between 13 and 15 years of age, diagnosed with pit and fissure caries by visual and DIAGNOdent examination, were chosen for sealant placement on their mandibular molars. The sealants were placed at random, after which, impressions were made with polyvinyl siloxane and casts were fabricated. Dies were prepared, each of which were sputter coated with gold in order to be examined under a scanning electron microscope. The following morphologies were analyzed from dies from each of the sealant groups: Continuous margins, sealant fractures, marginal fissures and enamel fractures. After six months, they were recalled for impression making. Dies were prepared and microscopically analyzed as mentioned. Based on the time of evaluation, there were two groups: Initial group (soon after placement) and final group (after six months). Statistical analysis was done using the paired 't' test and One-way analysis of variance (ANOVA). Clinpro had the greatest fracture resistance, followed by Conseal F and Helioseal F. The occurrence of marginal fissure was found to be least with Clinpro.
Aamland, Aase; Werner, Erik L; Malterud, Kirsti
2013-06-01
Medically unexplained physical symptoms (MUPS) form a major cause of sickness absence. The purpose of this study was to explore factors which may influence further marginalization among patients with MUPS on long-term sickness absence. Two focus-group discussions were conducted with a purposive sample of 12 participants, six men and six women, aged 24-59 years. Their average duration of sickness absence was 10.5 months. Participants were invited to share stories about experiences from the process leading to the ongoing sickness absence, with a focus on the causes being medically unexplained. Systematic text condensation was applied for analysis. Inspired by theories of marginalization and coping, the authors searched for knowledge of how patients' positive resources can be mobilized to counteract processes of marginality. Analysis revealed how invisible symptoms and lack of objective findings were perceived as an additional burden to the sickness absence itself. Factors that could counteract further marginalization were a supportive social network, positive coping strategies such as keeping to the daily schedule and physical activity, and positive attention and confidence from professionals. Confidence from both personal and professional contacts is crucial. GPs have an important and appreciated role in this aspect.
Amit, Moran; Na'ara, Shorook; Trejo-Leider, Leonor; Ramer, Naomi; Burstein, David; Yue, Ma; Miles, Brett; Yang, Xinjie; Lei, Delin; Bjoerndal, Kristine; Godballe, Christian; Mücke, Thomas; Wolff, Klaus-Dietrich; Eckardt, André M; Copelli, Chiara; Sesenna, Enrico; Patel, Snehal; Ganly, Ian; Gil, Ziv
2017-05-01
The mainstay of treatment in adenoid cystic carcinoma (ACC) of the head and neck is surgical resection with negative margins. The purpose of this study was to define the margin status that associates with survival outcomes of ACC of the head and neck. We conducted univariate and multivariate analyses of international data. Data of 507 patients with ACC of the head and neck were analyzed; negative margins defined as ≥5 mm were detected in 253 patients (50%). On multivariate analysis, the hazard ratios (HRs) of positive margin status were 2.68 (95% confidence interval [CI], 1.2-6.2; p = .04) and 2.63 (95% CI, 1.1-6.3; p = .03) for overall survival (OS) and disease-specific survival (DSS), respectively. Close margins had no significant impact on outcome, with HRs of 1.1 (95% CI, 0.4-3.0; p = .12) and 1.07 (95% CI, 0.3-3.4; p = .23) for OS and DSS, respectively, relative with negative margins. In head and neck ACC, positive margins are associated with the worst outcome. Negative or close margins are associated with improved outcome, regardless of the distance from the tumor. © 2017 Wiley Periodicals, Inc. Head Neck 39: 1008-1014, 2017. © 2017 Wiley Periodicals, Inc.
Arthurs, Benjamin J; Lamoreaux, Wayne T; Mackay, Alexander R; Demakas, John J; Giddings, Neil A; Fairbanks, Robert K; Cooke, Barton S; Elaimy, Ameer L; Peressini, Ben; Lee, Christopher M
2011-06-01
We present the previously unreported outcomes of 70 patients treated with Gamma knife radiosurgery for vestibular schwannoma (VS), including comprehensive analysis of clinical outcomes and the effects of lower marginal doses. We performed a retrospective study of patients treated for VS at Gamma knife of Spokane between 2003 and 2008. Endpoints measured include tumor control, hearing preservation, and facial nerve preservation, including the effect of tumor size and marginal dose. Statistical analysis was performed with Wilcoxon signed-rank test, paired Student t test, Mann-Whitney U test, Kendall's rank correlation, Fisher exact test, and Liddell's exact χ(2) test for matched pairs. With a mean follow-up of 26 months, 93.8% of tumors either shrank or remained static after receiving a mean marginal dose of 12.7 Gy. Tumor control was independent of marginal dose or tumor size. Hearing preservation was achieved in 64% of patients with serviceable function before the treatment. Hearing changes were independent of dose or tumor size. Preservation of good facial nerve function was achieved in 95% of patients. Post-treatment hydrocephalus occurred in 4.4% of patients, but no other significant morbidities were elucidated. In the treatment of VS, contemporary radiosurgical techniques and the use of marginal doses below 13 Gy offer excellent tumor control, at high rates relative to surgical intervention. These findings are independent of marginal dose and tumor size. Patients should be informed about the benefits and risks of radiosurgery and microsurgery before choosing an intervention. Further analysis of post-treatment outcomes should be encouraged as follow-up times increase and the treatment protocols continue to evolve.
The assessment of mucosal surgical margins in head and neck cancer surgery with narrow band imaging.
Šifrer, Robert; Urbančič, Jure; Strojan, Primož; Aničin, Aleksandar; Žargi, Miha
2017-07-01
The diagnostic gain of narrow band imaging in the definition of surgical margins in the treatment of head and neck cancer was evaluated. A prospective study, blinded to the pathologist, with historical comparison. The study group included 45 patients subjected to the intraoperative definition of margins by narrow band imaging. The control group included 55 patients who had undergone standard definition of margins. All patients underwent resection of the tumor and frozen section analysis of superficial margins. The rate of initial R 0 resection and the ratio of histologically negative margins for both groups were statistically compared. The rate of initial R 0 resection in the study group and in the control group was 88.9% and 70.9% (P = .047), and the ratio of histologically negative margins was 95.9% and 88.4% (P = .017), respectively. Narrow band imaging reveals a microscopic extension of the tumor that could be effectively used to better define superficial margins and to achieve a higher rate of initial R 0 resections. 4 Laryngoscope, 127:1577-1582, 2017. © 2016 The American Laryngological, Rhinological and Otological Society, Inc.
Effect of posterior crown margin placement on gingival health.
Reitemeier, Bernd; Hänsel, Kristina; Walter, Michael H; Kastner, Christian; Toutenburg, Helge
2002-02-01
The clinical impact of posterior crown margin placement on gingival health has not been thoroughly quantified. This study evaluated the effect of posterior crown margin placement with multivariate analysis. Ten general dentists reviewed 240 patients with 480 metal-ceramic crowns in a prospective clinical trial. The alloy was randomly selected from 2 high gold, 1 low gold, and 1 palladium alloy. Variables were the alloy used, oral hygiene index score before treatment, location of crown margins at baseline, and plaque index and sulcus bleeding index scores recorded for restored and control teeth after 1 year. The effect of crown margin placement on sulcular bleeding and plaque accumulation was analyzed with regression models (P<.05). The probability of plaque at 1 year increased with increasing oral hygiene index score before treatment. The lingual surfaces demonstrated the highest probability of plaque. The risk of bleeding at intrasulcular posterior crown margins was approximately twice that at supragingival margins. Poor oral hygiene before treatment and plaque also were associated with sulcular bleeding. Facial sites exhibited a lower probability of sulcular bleeding than lingual surfaces. Type of alloy did not influence sulcular bleeding. In this study, placement of crown margins was one of several parameters that affected gingival health.
Laitinen, M K; Parry, M C; Albergo, J I; Grimer, R J; Jeys, L M
2017-02-01
Due to the complex anatomy of the pelvis, limb-sparing resections of pelvic tumours achieving adequate surgical margins, can often be difficult. The advent of computer navigation has improved the precision of resection of these lesions, though there is little evidence comparing resection with or without the assistance of navigation. Our aim was to evaluate the efficacy of navigation-assisted surgery for the resection of pelvic bone tumours involving the posterior ilium and sacrum. Using our prospectively updated institutional database, we conducted a retrospective case control study of 21 patients who underwent resection of the posterior ilium and sacrum, for the treatment of a primary sarcoma of bone, between 1987 and 2015. The resection was performed with the assistance of navigation in nine patients and without navigation in 12. We assessed the accuracy of navigation-assisted surgery, as defined by the surgical margin and how this affects the rate of local recurrence, the disease-free survival and the effects on peri-and post-operative morbidity. The mean age of the patients was 36.4 years (15 to 66). The mean size of the tumour was 10.9 cm. In the navigation-assisted group, the margin was wide in two patients (16.7%), marginal in six (66.7%) and wide-contaminated in one (11.1%) with no intralesional margin. In the non-navigated-assisted group; the margin was wide in two patients (16.7%), marginal in five (41.7%), intralesional in three (25.0%) and wide-contaminated in two (16.7%). Local recurrence occurred in two patients in the navigation-assisted group (22.2%) and six in the non-navigation-assisted group (50.0%). The disease-free survival was significantly better when operated with navigation-assistance (p = 0.048). The blood loss and operating time were less in the navigated-assisted group, as was the risk of a foot drop post-operatively. The introduction of navigation-assisted surgery for the resection of tumours of the posterior ilium and sacrum has increased the safety for the patients and allows for a better oncological outcome. Cite this article: Bone Joint J 2017;99-B:261-6. ©2017 The British Editorial Society of Bone & Joint Surgery.
Shembesh, Marwa; Ali, Ala; Finkelman, Matthew; Weber, Hans-Peter; Zandparsa, Roya
2017-10-01
To compare the marginal adaptation of 3-unit zirconia fixed dental prostheses (FDPs) obtained from intraoral digital scanners (Lava True Definition, Cadent iTero), scanning of a conventional silicone impression, and the resulting master cast with an extraoral scanner (3Shape lab scanner). One reference model was fabricated from intact, non-carious, unrestored human mandibular left first premolar and first molar teeth (teeth #19 and 21), prepared for a three-unit all-ceramic FDP. Impressions of the reference model were obtained using four impression systems (n = 10), group 1 (PVS impression scan), group 2 (stone cast scan), group 3 (Cadent iTero), and group 4 (Lava True Defintion). Then the three-unit zirconia FDPs were milled. Marginal adaptation of the zirconia FDPs was evaluated using an optical comparator at four points on each abutment. The mean (SD) was reported for each group. One-way ANOVA was used to assess the statistical significance of the results, with post hoc tests conducted via Tukey's HSD. p < 0.05 was considered statistically significant. All analyses were done using SPSS 22.0. The mean (SD) marginal gaps for the recorded data from highest to lowest were silicone impression scans 81.4 μm (6.8), Cadent iTero scan 62.4 μm (5.0), master cast scan 50.2 μm (6.1), and Lava True definition scan 26.6 μm (4.7). One-way ANOVA revealed significant differences (p < 0.001) in the mean marginal gap among the groups. The Tukey's HSD tests demonstrated that the differences between all groups (silicone impression scan, master cast scan, Lava True definition scan, iTero Cadent scan) were statistically significant (all p < 0.001). On the basis of the criterion of 120 μm as the limit of clinical acceptance, all marginal discrepancy values of all groups were clinically acceptable. Within the confines of this in vitro study, it can be concluded that the marginal gap of all impression techniques was within the acceptable clinical limit (120 μm). Group 4 (Lava True Defintion) showed the lowest average gap among all groups followed by group 2 (stone cast scan), group 3 (Cadent iTero), and group 1 (PVS impression scan); these differences were statistically significant. © 2016 by the American College of Prosthodontists.
Effect of different resin luting cements on the marginal fit of lithium disilicate pressed crowns.
Mounajjed, Radek; Salinas, Thomas J; Ingr, Tomas; Azar, Basel
2017-11-15
The vertical marginal discrepancy of restorations can increase upon cementation, and poor marginal fit can lead to cement dissolution, marginal discoloration, microleakage, and secondary caries. The amount of increase is related to the type of luting cement used, but how lithium disilicate pressed crowns are affected by different resin cements is unclear. The purpose of this in vitro study was to compare the effect of using different resin luting cements on the vertical marginal discrepancy of lithium disilicate pressed crowns. A total of 18 intact extracted mandibular third molars were disinfected in a solution of 10% formalin for 7 days and were then prepared to receive a ceramic crown. Impressions were made with polyvinyl siloxane and lithium disilicate pressed crowns made and cemented with 1 of 3 resin luting cements. The marginal discrepancy was measured at 4 points on the finishing line of each tooth, with optical microscopy at ×200 magnification before and after cementation. Statistical analysis was done with the Kruskal-Wallis test to compare the median marginal increase among the 3 groups. The least amount of marginal increase after cementation was with Harvard PremiumFlow cement, with an average marginal increase of 42 ±11 μm. RelyX Ultimate cement increased the margins by an average 45 ±29 μm. The highest marginal increase was found in the Enamel Plus HRi preheated composite resin group (116 ±47 μm). The marginal increase of pressed crowns cemented with preheated composite resin (Enamel Plus HRi) exceeded the clinically acceptable range of marginal discrepancy. Copyright © 2017 Editorial Council for the Journal of Prosthetic Dentistry. Published by Elsevier Inc. All rights reserved.
Duan, Fumei; Wang, Yong; Wang, Ying; Zhao, Han
2018-06-16
The calculation of marginal abatement costs of CO 2 plays a vital role in meeting China's 2020 emission reduction targets by providing reference for determining carbon tax and carbon trading pricing. However, most existing researches only used one method to discuss regional and industrial marginal abatement costs, and almost no studies predicted future marginal abatement costs from the perspective of CO 2 emission efficiency. To make up for the gaps, this paper first estimates marginal abatement costs of CO 2 in three major industries of 30 provinces in China from 2005 to 2015 based on three assumptions. Second, based on the principle of fairness and efficiency, China's 2020 emission reduction targets are decomposed by province. Based on the ZSG-C-DDF model, the marginal abatement costs of CO 2 in all provinces in China in 2020 are estimated and compared with the marginal abatement costs of 2005 to 2015. The results show that (1) from 2005 to 2015, marginal abatement costs of CO 2 in all provinces show a fluctuating upward trend; (2) compared with the marginal abatement costs of primary industry or tertiary industry, most provinces have lower marginal abatement costs for secondary industry; and (3) the average marginal abatement costs of CO 2 for China in 2020 are 2766.882 Yuan/tonne for the 40% carbon intensity reduction target and 3334.836 Yuan/tonne for the 45% target, showing that the higher the emission reduction target, the higher the marginal abatement costs of CO 2 . (4) Overall, the average marginal abatement costs of CO 2 in China by 2020 are higher than those in 2005-2015. The empirical analysis in this paper can provide multiple references for environmental policy makers.
Sasaki, Ryo; Angelaki, Dora E.
2017-01-01
We use visual image motion to judge the movement of objects, as well as our own movements through the environment. Generally, image motion components caused by object motion and self-motion are confounded in the retinal image. Thus, to estimate heading, the brain would ideally marginalize out the effects of object motion (or vice versa), but little is known about how this is accomplished neurally. Behavioral studies suggest that vestibular signals play a role in dissociating object motion and self-motion, and recent computational work suggests that a linear decoder can approximate marginalization by taking advantage of diverse multisensory representations. By measuring responses of MSTd neurons in two male rhesus monkeys and by applying a recently-developed method to approximate marginalization by linear population decoding, we tested the hypothesis that vestibular signals help to dissociate self-motion and object motion. We show that vestibular signals stabilize tuning for heading in neurons with congruent visual and vestibular heading preferences, whereas they stabilize tuning for object motion in neurons with discrepant preferences. Thus, vestibular signals enhance the separability of joint tuning for object motion and self-motion. We further show that a linear decoder, designed to approximate marginalization, allows the population to represent either self-motion or object motion with good accuracy. Decoder weights are broadly consistent with a readout strategy, suggested by recent computational work, in which responses are decoded according to the vestibular preferences of multisensory neurons. These results demonstrate, at both single neuron and population levels, that vestibular signals help to dissociate self-motion and object motion. SIGNIFICANCE STATEMENT The brain often needs to estimate one property of a changing environment while ignoring others. This can be difficult because multiple properties of the environment may be confounded in sensory signals. The brain can solve this problem by marginalizing over irrelevant properties to estimate the property-of-interest. We explore this problem in the context of self-motion and object motion, which are inherently confounded in the retinal image. We examine how diversity in a population of multisensory neurons may be exploited to decode self-motion and object motion from the population activity of neurons in macaque area MSTd. PMID:29030435
Mirzazadeh, Ali; Haghdoost, Ali Akbar; Nedjat, Saharnaz; Navadeh, Soodabeh; McFarland, Willi; Mohammad, Kazem
2013-02-01
We quantified discrepancies in reported behaviors of female sex workers (FSW) by comparing 63 face-to-face interviews (FTFI) to in-depth interviews (IDI), with corroboration of the directions and magnitudes of reporting by a panel of psychologists who work with FSW. Sensitivities, specificities, positive and negative predictive values (PPV and NPV) were assessed for FTFI responses using IDI as a "gold standard". Sensitivities were lowest in reporting symptoms of sexually transmitted infections (63.9 %), finding sex partners in venues (52.4 %) and not receiving HIV test results (66.7 %). Specificities (all >83 %) and PPVs (all >74.0 %) were higher than NPV. FSW significantly under-reported number of clients, sexual contacts and non-condom use sex acts with clients and number of days engaging in sex work in the preceding week. This study provides a quantified gauge of reporting biases in FSW behaviors. Such estimates and methods help better understand true HIV risk in marginalized populations and calibrate survey estimates accordingly.
Cervantes-Sanchez, Fernando; Hernandez-Aguirre, Arturo; Solorio-Meza, Sergio; Ornelas-Rodriguez, Manuel; Torres-Cisneros, Miguel
2016-01-01
This paper presents a novel method for improving the training step of the single-scale Gabor filters by using the Boltzmann univariate marginal distribution algorithm (BUMDA) in X-ray angiograms. Since the single-scale Gabor filters (SSG) are governed by three parameters, the optimal selection of the SSG parameters is highly desirable in order to maximize the detection performance of coronary arteries while reducing the computational time. To obtain the best set of parameters for the SSG, the area (A z) under the receiver operating characteristic curve is used as fitness function. Moreover, to classify vessel and nonvessel pixels from the Gabor filter response, the interclass variance thresholding method has been adopted. The experimental results using the proposed method obtained the highest detection rate with A z = 0.9502 over a training set of 40 images and A z = 0.9583 with a test set of 40 images. In addition, the experimental results of vessel segmentation provided an accuracy of 0.944 with the test set of angiograms. PMID:27738422
Transient Stability Output Margin Estimation Based on Energy Function Method
NASA Astrophysics Data System (ADS)
Miwa, Natsuki; Tanaka, Kazuyuki
In this paper, a new method of estimating critical generation margin (CGM) in power systems is proposed from the viewpoint of transient stability diagnostic. The proposed method has the capability to directly compute the stability limit output for a given contingency based on transient energy function method (TEF). Since CGM can be directly obtained by the limit output using estimated P-θ curves and is easy to understand, it is more useful rather than conventional critical clearing time (CCT) of energy function method. The proposed method can also estimate CGM as its negative value that means unstable in present load profile, then negative CGM can be directly utilized as generator output restriction. The proposed method is verified its accuracy and fast solution ability by applying to simple 3-machine model and IEEJ EAST10-machine standard model. Furthermore the useful application to severity ranking of transient stability for a lot of contingency cases is discussed by using CGM.
Distribution of Particles in the Z-axis of Tissue Sections: Relevance for Counting Methods.
von Bartheld, Christopher S
2012-01-01
The distribution of particles in the z-axis of thick tissue sections has gained considerable attention, primarily because of implications for the accuracy of modern stereological counting methods. Three major types of artifacts can affect these sections: loss of particles from the surfaces of tissue sections (lost caps), homogeneous collapse in the z-axis, and differential deformation in the z-axis. Initially it was assumed that thick sections were not compromised by differential shrinkage or compression (differential uniform deformation). Studies in the last decade showed that such artifacts are common and that they depend on embedding media and sectioning devices. Paraffin, glycolmethacrylate and vibratome sections are affected by this artifact, but not celloidin sections or cryostat-derived cryosections. Differential distribution of particles in the z-axis is likely due to compression of the surface areas (margins) during sectioning, resulting in differential particle densities in the core and margin of tissue sections. This deformation of tissue sections can be rapidly assessed by measuring the position of particles in the z-axis. The analysis is complicated by potential secondary effects on section surfaces through loss of particles, the so-called "lost caps" phenomenon. Secondary effects necessitate the use of guard spaces, while their use in case of primary effects (compression due to sectioning) would enhance the artifact's impact on bias. Symmetric versus asymmetric patterns of z-axis distortion can give clues to distinguish primary and secondary effects. Studies that use the optical disector need to take these parameters into account to minimize biases.
NASA Astrophysics Data System (ADS)
Gao, Liang
This thesis describes the development of a combined label-free imaging and analytical strategy for intraoperative characterization of cancer lesions using the coherent anti-Stokes Raman scattering imaging (CARS) technique. A cell morphology-based analytical platform is developed to characterize CARS images and, hence, provide diagnostic information using disease-related pathology features. This strategy is validated for three different applications, including margin detection for radical prostatectomy, differential diagnosis of lung cancer, as well as detection and differentiation of breast cancer subtypes for in situ analysis of margin status during lumpectomy. As the major contribution of this thesis, the developed analytical strategy shows high accuracy and specificity for all three diseases and thus has introduced the CARS imaging technique into the field of human cancer diagnosis, which holds substantial potential for clinical translations. In addition, I have contributed a project aimed at miniaturizing the CARS imaging device into a microendoscope setup through a fiber-delivery strategy. A four-wave-mixing (FWM) background signal, which is caused by simultaneous delivery of the two CARS-generating excitation laser beams, is initially identified. A polarization-based strategy is then introduced and tested for suppression of this FWM noise. The approach shows effective suppression of the FWM signal, both on microscopic and prototype endoscopic setups, indicating the potential of developing a novel microendoscope with a compatible size for clinical use. These positive results show promise for the development of an all-fiber-based, label-free imaging and analytical platform for minimally invasive detection and diagnosis of cancers during surgery or surgical-biopsy, thus improving surgical outcomes and reducing patients' suffering.