Sample records for masking level difference

  1. What's in a mask? Information masking with forward and backward visual masks.

    PubMed

    Davis, Chris; Kim, Jeesun

    2011-10-01

    Three experiments tested how the physical format and information content of forward and backward masks affected the extent of visual pattern masking. This involved using different types of forward and backward masks with target discrimination measured by percentage correct in the first experiment (with a fixed target duration) and by an adaptive threshold procedure in the last two. The rationale behind the manipulation of the content of the masks stemmed from masking theories emphasizing attentional and/or conceptual factors rather than visual ones. Experiment 1 used word masks and showed that masking was reduced (a masking reduction effect) when the forward and backward masks were the same word (although in different case) compared to when the masks were different words. Experiment 2 tested the extent to which a reduction in masking might occur due to the physical similarity between the forward and backward masks by comparing the effect of the same content of the masks in the same versus different case. The result showed a significant reduction in masking for same content masks but no significant effect of case. The last experiment examined whether the reduction in masking effect would be observed with nonword masks--that is, having no high-level representation. No reduction in masking was found from same compared to different nonword masks (Experiment 3). These results support the view that the conscious perception of a rapidly displayed target stimulus is in part determined by high-level perceptual/cognitive factors concerned with masking stimulus grouping and attention.

  2. Masking Level Difference Response Norms from Learning Disabled Individuals.

    ERIC Educational Resources Information Center

    Waryas, Paul A.; Battin, R. Ray

    1985-01-01

    The study presents normative data on Masking Level Difference (an improvement of the auditory processing of interaural time/intensity differences between signals and masking noises) for 90 learning disabled persons (4-35 years old). It was concluded that the MLD may quickly screen for auditory processing problems. (CL)

  3. Neural correlates of binaural masking level difference in the inferior colliculus of the barn owl (Tyto alba).

    PubMed

    Asadollahi, Ali; Endler, Frank; Nelken, Israel; Wagner, Hermann

    2010-08-01

    Humans and animals are able to detect signals in noisy environments. Detection improves when the noise and the signal have different interaural phase relationships. The resulting improvement in detection threshold is called the binaural masking level difference. We investigated neural mechanisms underlying the release from masking in the inferior colliculus of barn owls in low-frequency and high-frequency neurons. A tone (signal) was presented either with the same interaural time difference as the noise (masker) or at a 180 degrees phase shift as compared with the interaural time difference of the noise. The changes in firing rates induced by the addition of a signal of increasing level while masker level was kept constant was well predicted by the relative responses to the masker and signal alone. In many cases, the response at the highest signal levels was dominated by the response to the signal alone, in spite of a significant response to the masker at low signal levels, suggesting the presence of occlusion. Detection thresholds and binaural masking level differences were widely distributed. The amount of release from masking increased with increasing masker level. Narrowly tuned neurons in the central nucleus of the inferior colliculus had detection thresholds that were lower than or similar to those of broadly tuned neurons in the external nucleus of the inferior colliculus. Broadly tuned neurons exhibited higher masking level differences than narrowband neurons. These data suggest that detection has different spectral requirements from localization.

  4. Profiles of Patients Demonstrating Abnormal Masking Level Difference Response.

    ERIC Educational Resources Information Center

    Battin, R. Ray; Waryas, Paul A.

    1985-01-01

    Profiles of three persons (9-11 years old) with extremely reduced masking level difference results (scores which measure binaural release from masking) are reported. It is suggested that tests of the MLD appear to be a useful adjunct of an evaluation battery for patients with presumed auditory perceptual problems. (CL)

  5. Objective measures of binaural masking level differences and comodulation masking release based on late auditory evoked potentials.

    PubMed

    Epp, Bastian; Yasin, Ifat; Verhey, Jesko L

    2013-12-01

    The audibility of important sounds is often hampered due to the presence of other masking sounds. The present study investigates if a correlate of the audibility of a tone masked by noise is found in late auditory evoked potentials measured from human listeners. The audibility of the target sound at a fixed physical intensity is varied by introducing auditory cues of (i) interaural target signal phase disparity and (ii) coherent masker level fluctuations in different frequency regions. In agreement with previous studies, psychoacoustical experiments showed that both stimulus manipulations result in a masking release (i: binaural masking level difference; ii: comodulation masking release) compared to a condition where those cues are not present. Late auditory evoked potentials (N1, P2) were recorded for the stimuli at a constant masker level, but different signal levels within the same set of listeners who participated in the psychoacoustical experiment. The data indicate differences in N1 and P2 between stimuli with and without interaural phase disparities. However, differences for stimuli with and without coherent masker modulation were only found for P2, i.e., only P2 is sensitive to the increase in audibility, irrespective of the cue that caused the masking release. The amplitude of P2 is consistent with the psychoacoustical finding of an addition of the masking releases when both cues are present. Even though it cannot be concluded where along the auditory pathway the audibility is represented, the P2 component of auditory evoked potentials is a candidate for an objective measure of audibility in the human auditory system. Copyright © 2013 Elsevier B.V. All rights reserved.

  6. Effects of non-simultaneous masking on the binaural masking level difference

    PubMed Central

    Buss, Emily; Hall III, Joseph W.

    2011-01-01

    The present study sought to clarify the role of non-simultaneous masking in the binaural masking level difference for maskers that fluctuate in level. In the first experiment the signal was a brief 500-Hz tone, and the masker was a bandpass noise (100–2000 Hz), with the initial and final 200-ms bursts presented at 40-dB spectrum level and the inter-burst gap presented at 20-dB spectrum level. Temporal windows were fitted to thresholds measured for a range of gap durations and signal positions within the gap. In the second experiment, individual differences in out of phase (NoSπ) thresholds were compared for a brief signal in a gapped bandpass masker, a brief signal in a steady bandpass masker, and a long signal in a narrowband (50-Hz-wide) noise masker. The third experiment measured brief tone detection thresholds in forward, simultaneous, and backward masking conditions for a 50- and for a 1900-Hz-wide noise masker centered on the 500-Hz signal frequency. Results are consistent with comparable temporal resolution in the in phase (NoSo) and NoSπ conditions and no effect of temporal resolution on individual observers’ ability to utilize binaural cues in narrowband noise. The large masking release observed for a narrowband noise masker may be due to binaural masking release from non-simultaneous, informational masking. PMID:21361448

  7. Modulation cues influence binaural masking-level difference in masking-pattern experiments.

    PubMed

    Nitschmann, Marc; Verhey, Jesko L

    2012-03-01

    Binaural masking patterns show a steep decrease in the binaural masking-level difference (BMLD) when masker and signal have no frequency component in common. Experimental threshold data are presented together with model simulations for a diotic masker centered at 250 or 500 Hz and a bandwidth of 10 or 100 Hz masking a sinusoid interaurally in phase (S(0)) or in antiphase (S(π)). Simulations with a binaural model, including a modulation filterbank for the monaural analysis, indicate that a large portion of the decrease in the BMLD in remote-masking conditions may be due to an additional modulation cue available for monaural detection. © 2012 Acoustical Society of America

  8. Matching OPC and masks on 300-mm lithography tools utilizing variable illumination settings

    NASA Astrophysics Data System (ADS)

    Palitzsch, Katrin; Kubis, Michael; Schroeder, Uwe P.; Schumacher, Karl; Frangen, Andreas

    2004-05-01

    CD control is crucial to maximize product yields on 300mm wafers. This is particularly true for DRAM frontend lithography layers, like gate level, and deep trench (capacitor) level. In the DRAM process, large areas of the chip are taken up by array structures, which are difficult to structure due to aggressive pitch requirements. Consequently, the lithography process is centered such that the array structures are printed on target. Optical proximity correction is applied to print gate level structures in the periphery circuitry on target. Only slight differences of the different Zernike terms can cause rather large variations of the proximity curves, resulting in a difference of isolated and semi-isolated lines printed on different tools. If the deviations are too large, tool specific OPC is needed. The same is true for deep trench level, where the length to width ratio of elongated contact-like structures is an important parameter to adjust the electrical properties of the chip. Again, masks with specific biases for tools with different Zernikes are needed to optimize product yield. Additionally, mask making contributes to the CD variation of the process. Theoretically, the CD deviation caused by an off-centered mask process can easily eat up the majority of the CD budget of a lithography process. In practice, masks are very often distributed intelligently among production tools, such that lens and mask effects cancel each other. However, only dose adjusting and mask allocation may still result in a high CD variation with large systematical contributions. By adjusting the illumination settings, we have successfully implemented a method to reduce CD variation on our advanced processes. Especially inner and outer sigma for annular illumination, and the numerical aperture, can be optimized to match mask and stepper properties. This process will be shown to overcome slight lens and mask differences effectively. The effects on lithography process windows have to be considered, nonetheless.

  9. Masking release by combined spatial and masker-fluctuation effects in the open sound field.

    PubMed

    Middlebrooks, John C

    2017-12-01

    In a complex auditory scene, signals of interest can be distinguished from masking sounds by differences in source location [spatial release from masking (SRM)] and by differences between masker-alone and masker-plus-signal envelopes. This study investigated interactions between those factors in release of masking of 700-Hz tones in an open sound field. Signal and masker sources were colocated in front of the listener, or the signal source was shifted 90° to the side. In Experiment 1, the masker contained a 25-Hz-wide on-signal band plus flanking bands having envelopes that were either mutually uncorrelated or were comodulated. Comodulation masking release (CMR) was largely independent of signal location at a higher masker sound level, but at a lower level CMR was reduced for the lateral signal location. In Experiment 2, a brief signal was positioned at the envelope maximum (peak) or minimum (dip) of a 50-Hz-wide on-signal masker. Masking was released in dip more than in peak conditions only for the 90° signal. Overall, open-field SRM was greater in magnitude than binaural masking release reported in comparable closed-field studies, and envelope-related release was somewhat weaker. Mutual enhancement of masking release by spatial and envelope-related effects tended to increase with increasing masker level.

  10. Categorical scaling of partial loudness in a condition of masking release.

    PubMed

    Verhey, Jesko L; Heeren, Wiebke

    2015-08-01

    Categorical loudness scaling was used to measure suprathreshold release from masking. The signal was a 986-Hz sinusoid that was embedded in a bandpass-filtered masking noise. This noise was either unmodulated or was amplitude modulated with a square-wave modulator. The unmodulated noise had either the same level as the modulated noise or had a level that was reduced by the difference in thresholds for the 986-Hz signal obtained with the modulated and unmodulated noise masker presented at the same level (i.e., the masking release). A comparison with loudness matching data of the same set of subjects showed that the data obtained with loudness scaling capture main aspects of the change in suprathreshold perception of the sinusoid when the masker was modulated. The scaling data for the signal masked by the unmodulated noise with the reduced masker level were similar to that for the signal embedded in the modulated noise. This similarity supports the hypothesis that the mechanism eliciting the masking release is effectively reducing the masker level.

  11. Interaural level differences do not suffice for restoring spatial release from masking in simulated cochlear implant listening.

    PubMed

    Ihlefeld, Antje; Litovsky, Ruth Y

    2012-01-01

    Spatial release from masking refers to a benefit for speech understanding. It occurs when a target talker and a masker talker are spatially separated. In those cases, speech intelligibility for target speech is typically higher than when both talkers are at the same location. In cochlear implant listeners, spatial release from masking is much reduced or absent compared with normal hearing listeners. Perhaps this reduced spatial release occurs because cochlear implant listeners cannot effectively attend to spatial cues. Three experiments examined factors that may interfere with deploying spatial attention to a target talker masked by another talker. To simulate cochlear implant listening, stimuli were vocoded with two unique features. First, we used 50-Hz low-pass filtered speech envelopes and noise carriers, strongly reducing the possibility of temporal pitch cues; second, co-modulation was imposed on target and masker utterances to enhance perceptual fusion between the two sources. Stimuli were presented over headphones. Experiments 1 and 2 presented high-fidelity spatial cues with unprocessed and vocoded speech. Experiment 3 maintained faithful long-term average interaural level differences but presented scrambled interaural time differences with vocoded speech. Results show a robust spatial release from masking in Experiments 1 and 2, and a greatly reduced spatial release in Experiment 3. Faithful long-term average interaural level differences were insufficient for producing spatial release from masking. This suggests that appropriate interaural time differences are necessary for restoring spatial release from masking, at least for a situation where there are few viable alternative segregation cues.

  12. Noninvasive CPAP with face mask: comparison among new air-entrainment masks and the Boussignac valve.

    PubMed

    Mistraletti, Giovanni; Giacomini, Matteo; Sabbatini, Giovanni; Pinciroli, Riccardo; Mantovani, Elena S; Umbrello, Michele; Palmisano, Debora; Formenti, Paolo; Destrebecq, Anne L L; Iapichino, Gaetano

    2013-02-01

    The performances of 2 noninvasive CPAP systems (high flow and low flow air-entrainment masks) were compared to the Boussignac valve in 3 different scenarios. Scenario 1: pneumatic lung simulator with a tachypnea pattern (tidal volume 800 mL at 40 breaths/min). Scenario 2: Ten healthy subjects studied during tidal breaths and tachypnea. Scenario 3: Twenty ICU subjects enrolled for a noninvasive CPAP session. Differences between set and effective CPAP level and F(IO(2)), as well as the lowest airway pressure and the pressure swing around the imposed CPAP level, were analyzed. The lowest airway pressure and swing were correlated to the pressure-time product (area of the airway pressure curve below the CPAP level) measured with the simulator. P(aO(2)) was a subject's further performance index. Lung simulator: Boussignac F(IO(2)) was 0.54, even if supplied with pure oxygen. The air-entrainment masks had higher swing than the Boussignac (P = .007). Pressure-time product correlated better with pressure swing (Spearman correlation coefficient [ρ] = 0.97) than with lowest airway pressure (ρ = 0.92). In healthy subjects, the high-flow air-entrainment mask showed lower difference between set and effective F(IO(2)) (P < .001), and lowest airway pressure (P < .001), compared to the Boussignac valve. In all measurements the Boussignac valve showed higher than imposed CPAP level (P < .001). In ICU subjects the high-flow mask had lower swing than the Boussignac valve (P = .03) with similar P(aO(2)) increase. High-flow air-entrainment mask showed the best performance in human subjects. During high flow demand, the Boussignac valve delivered lower than expected F(IO(2)) and showed higher dynamic hyper-pressurization than the air-entrainment masks. © 2013 Daedalus Enterprises.

  13. The Effect of Otitis Media with Effusion on the Masking-Level Difference and the Auditory Brainstem Response.

    ERIC Educational Resources Information Center

    Hall, Joseph W.; Grose, John H.

    1993-01-01

    This study of 14 children (ages 5-9) with a history of otitis media with effusion found that subjects had significantly reduced masking-level differences (MLD) compared to controls. Results suggest that the reduction in MLD may be related to abnormal brainstem processing. (Author/JDD)

  14. Electrophysiological Evidence for the Sources of the Masking Level Difference

    ERIC Educational Resources Information Center

    Fowler, Cynthia G.

    2017-01-01

    Purpose: The purpose of this review article is to review evidence from auditory evoked potential studies to describe the contributions of the auditory brainstem and cortex to the generation of the masking level difference (MLD). Method: A literature review was performed, focusing on the auditory brainstem, middle, and late latency responses used…

  15. Oronasal Masks Require a Higher Pressure than Nasal and Nasal Pillow Masks for the Treatment of Obstructive Sleep Apnea.

    PubMed

    Deshpande, Sheetal; Joosten, Simon; Turton, Anthony; Edwards, Bradley A; Landry, Shane; Mansfield, Darren R; Hamilton, Garun S

    2016-09-15

    Oronasal masks are frequently used for continuous positive airway pressure (CPAP) treatment in patients with obstructive sleep apnea (OSA). The aim of this study was to (1) determine if CPAP requirements are higher for oronasal masks compared to nasal mask interfaces and (2) assess whether polysomnography and patient characteristics differed among mask preference groups. Retrospective analysis of all CPAP implementation polysomnograms between July 2013 and June 2014. Prescribed CPAP level, polysomnography results and patient data were compared according to mask type (n = 358). Oronasal masks were used in 46%, nasal masks in 35% and nasal pillow masks in 19%. There was no difference according to mask type for baseline apnea-hypopnea index (AHI), body mass index (BMI), waist or neck circumference. CPAP level was higher for oronasal masks, 12 (10-15.5) cm H2O compared to nasal pillow masks, 11 (8-12.5) cm H2O and nasal masks, 10 (8-12) cm H2O, p < 0.0001 (Median [interquartile range]). Oronasal mask type, AHI, age, and BMI were independent predictors of a higher CPAP pressure (p < 0.0005, adjusted R(2) = 0.26.). For patients with CPAP ≥ 15 cm H2O, there was an odds ratio of 4.5 (95% CI 2.5-8.0) for having an oronasal compared to a nasal or nasal pillow mask. Residual median AHI was higher for oronasal masks (11.3 events/h) than for nasal masks (6.4 events/h) and nasal pillows (6.7 events/h), p < 0.001. Compared to nasal mask types, oronasal masks are associated with higher CPAP pressures (particularly pressures ≥ 15 cm H2O) and a higher residual AHI. Further evaluation with a randomized control trial is required to definitively establish the effect of mask type on pressure requirements. A commentary on this article appears in this issue on page 1209. © 2016 American Academy of Sleep Medicine.

  16. Masking Release in Children and Adults With Hearing Loss When Using Amplification

    PubMed Central

    McCreery, Ryan; Kopun, Judy; Lewis, Dawna; Alexander, Joshua; Stelmachowicz, Patricia

    2016-01-01

    Purpose This study compared masking release for adults and children with normal hearing and hearing loss. For the participants with hearing loss, masking release using simulated hearing aid amplification with 2 different compression speeds (slow, fast) was compared. Method Sentence recognition in unmodulated noise was compared with recognition in modulated noise (masking release). Recognition was measured for participants with hearing loss using individualized amplification via the hearing-aid simulator. Results Adults with hearing loss showed greater masking release than the children with hearing loss. Average masking release was small (1 dB) and did not depend on hearing status. Masking release was comparable for slow and fast compression. Conclusions The use of amplification in this study contrasts with previous studies that did not use amplification. The results suggest that when differences in audibility are reduced, participants with hearing loss may be able to take advantage of dips in the noise levels, similar to participants with normal hearing. Although children required a more favorable signal-to-noise ratio than adults for both unmodulated and modulated noise, masking release was not statistically different. However, the ability to detect a difference may have been limited by the small amount of masking release observed. PMID:26540194

  17. Developmental Effects in the Masking-Level Difference

    ERIC Educational Resources Information Center

    Hall, Joseph W.; Buss, Emily; Grose, John H.; Dev, Madhu B.

    2004-01-01

    Adults and children (aged 5 years 1 month to 10 years 8 months) were tested in a masking-level difference (MLD) paradigm in which detection of brief signals was contrasted for signal placement in masker envelope maxima versus masker envelope minima. Maskers were 50-Hz-wide noise bands centered on 500 Hz, and the signals were So or S[pi] 30-ms,…

  18. Brightness masking is modulated by disparity structure.

    PubMed

    Pelekanos, Vassilis; Ban, Hiroshi; Welchman, Andrew E

    2015-05-01

    The luminance contrast at the borders of a surface strongly influences surface's apparent brightness, as demonstrated by a number of classic visual illusions. Such phenomena are compatible with a propagation mechanism believed to spread contrast information from borders to the interior. This process is disrupted by masking, where the perceived brightness of a target is reduced by the brief presentation of a mask (Paradiso & Nakayama, 1991), but the exact visual stage that this happens remains unclear. In the present study, we examined whether brightness masking occurs at a monocular-, or a binocular-level of the visual hierarchy. We used backward masking, whereby a briefly presented target stimulus is disrupted by a mask coming soon afterwards, to show that brightness masking is affected by binocular stages of the visual processing. We manipulated the 3-D configurations (slant direction) of the target and mask and measured the differential disruption that masking causes on brightness estimation. We found that the masking effect was weaker when stimuli had a different slant. We suggest that brightness masking is partly mediated by mid-level neuronal mechanisms, at a stage where binocular disparity edge structure has been extracted. Copyright © 2015 The Authors. Published by Elsevier Ltd.. All rights reserved.

  19. The extended functional neuroanatomy of emotional processing biases for masked faces in major depressive disorder.

    PubMed

    Victor, Teresa A; Furey, Maura L; Fromm, Stephen J; Bellgowan, Patrick S F; Öhman, Arne; Drevets, Wayne C

    2012-01-01

    Major depressive disorder (MDD) is associated with a mood-congruent processing bias in the amygdala toward face stimuli portraying sad expressions that is evident even when such stimuli are presented below the level of conscious awareness. The extended functional anatomical network that maintains this response bias has not been established, however. To identify neural network differences in the hemodynamic response to implicitly presented facial expressions between depressed and healthy control participants. Unmedicated-depressed participants with MDD (n=22) and healthy controls (HC; n=25) underwent functional MRI as they viewed face stimuli showing sad, happy or neutral face expressions, presented using a backward masking design. The blood-oxygen-level dependent (BOLD) signal was measured to identify regions where the hemodynamic response to the emotionally valenced stimuli differed between groups. The MDD subjects showed greater BOLD responses than the controls to masked-sad versus masked-happy faces in the hippocampus, amygdala and anterior inferotemporal cortex. While viewing both masked-sad and masked-happy faces relative to masked-neutral faces, the depressed subjects showed greater hemodynamic responses than the controls in a network that included the medial and orbital prefrontal cortices and anterior temporal cortex. Depressed and healthy participants showed distinct hemodynamic responses to masked-sad and masked-happy faces in neural circuits known to support the processing of emotionally valenced stimuli and to integrate the sensory and visceromotor aspects of emotional behavior. Altered function within these networks in MDD may establish and maintain illness-associated differences in the salience of sensory/social stimuli, such that attention is biased toward negative and away from positive stimuli.

  20. Oronasal masks require higher levels of positive airway pressure than nasal masks to treat obstructive sleep apnea.

    PubMed

    Bettinzoli, Michela; Taranto-Montemurro, Luigi; Messineo, Ludovico; Corda, Luciano; Redolfi, Stefania; Ferliga, Mauro; Tantucci, Claudio

    2014-12-01

    The purpose of this study was to compare the therapeutic pressure determined by an automated CPAP device (AutoCPAP) during the titration period, between nasal and oronasal mask and the residual apnea-hypopnea index (AHI) on a subsequent poligraphy performed with the established therapeutic CPAP. As a retrospective study, 109 subjects with moderate and severe obstructive sleep apnea-hypopnea (apnea-hypopnea index≥15 events/h) were studied. CPAP titration was performed using an auto-titrating device. There was significant difference in the mean pressure delivered with autoCPAP between the group of patients using the nasal mask (mean 10.0 cmH2O±2.0 SD) and the group which used the oronasal mask (mean 11.2 cmH2O±2.1) (p<0.05). Residual apneas were lower when using a nasal mask: average AHI of 2.6±2.5 compared to 4.5±4.0 using an oronasal mask (p<0.05). On multivariate analysis, the only independent predictor of the level of therapeutic pressure of CPAP was the type of mask used (r=0.245, p 0.008). Therapeutic CPAP level for OSAH is higher when administered via oronasal mask, leaving more residual events. These findings suggest that nasal mask should be the first choice for OSAH treatment.

  1. Oronasal Masks Require a Higher Pressure than Nasal and Nasal Pillow Masks for the Treatment of Obstructive Sleep Apnea

    PubMed Central

    Deshpande, Sheetal; Joosten, Simon; Turton, Anthony; Edwards, Bradley A.; Landry, Shane; Mansfield, Darren R.; Hamilton, Garun S.

    2016-01-01

    Study Objectives: Oronasal masks are frequently used for continuous positive airway pressure (CPAP) treatment in patients with obstructive sleep apnea (OSA). The aim of this study was to (1) determine if CPAP requirements are higher for oronasal masks compared to nasal mask interfaces and (2) assess whether polysomnography and patient characteristics differed among mask preference groups. Methods: Retrospective analysis of all CPAP implementation polysomnograms between July 2013 and June 2014. Prescribed CPAP level, polysomnography results and patient data were compared according to mask type (n = 358). Results: Oronasal masks were used in 46%, nasal masks in 35% and nasal pillow masks in 19%. There was no difference according to mask type for baseline apnea-hypopnea index (AHI), body mass index (BMI), waist or neck circumference. CPAP level was higher for oronasal masks, 12 (10–15.5) cm H2O compared to nasal pillow masks, 11 (8–12.5) cm H2O and nasal masks, 10 (8–12) cm H2O, p < 0.0001 (Median [interquartile range]). Oronasal mask type, AHI, age, and BMI were independent predictors of a higher CPAP pressure (p < 0.0005, adjusted R2 = 0.26.). For patients with CPAP ≥ 15 cm H2O, there was an odds ratio of 4.5 (95% CI 2.5–8.0) for having an oronasal compared to a nasal or nasal pillow mask. Residual median AHI was higher for oronasal masks (11.3 events/h) than for nasal masks (6.4 events/h) and nasal pillows (6.7 events/h), p < 0.001. Conclusions: Compared to nasal mask types, oronasal masks are associated with higher CPAP pressures (particularly pressures ≥ 15 cm H2O) and a higher residual AHI. Further evaluation with a randomized control trial is required to definitively establish the effect of mask type on pressure requirements. Commentary: A commentary on this article appears in this issue on page 1209. Citation: Deshpande S, Joosten S, Turton A, Edwards BA, Landry S, Mansfield DR, Hamilton GS. Oronasal masks require a higher pressure than nasal and nasal pillow masks for the treatment of obstructive sleep apnea. J Clin Sleep Med 2016;12(9):1263–1268. PMID:27448430

  2. Rescuing Stimuli from Invisibility: Inducing a Momentary Release from Visual Masking with Pre-Target Entrainment

    ERIC Educational Resources Information Center

    Mathewson, Kyle E.; Fabiani, Monica; Gratton, Gabriele; Beck, Diane M.; Lleras, Alejandro

    2010-01-01

    At near-threshold levels of stimulation, identical stimulus parameters can result in very different phenomenal experiences. Can we manipulate which stimuli reach consciousness? Here we show that consciousness of otherwise masked stimuli can be experimentally induced by sensory entrainment. We preceded a backward-masked stimulus with a series of…

  3. Video encryption using chaotic masks in joint transform correlator

    NASA Astrophysics Data System (ADS)

    Saini, Nirmala; Sinha, Aloka

    2015-03-01

    A real-time optical video encryption technique using a chaotic map has been reported. In the proposed technique, each frame of video is encrypted using two different chaotic random phase masks in the joint transform correlator architecture. The different chaotic random phase masks can be obtained either by using different iteration levels or by using different seed values of the chaotic map. The use of different chaotic random phase masks makes the decryption process very complex for an unauthorized person. Optical, as well as digital, methods can be used for video encryption but the decryption is possible only digitally. To further enhance the security of the system, the key parameters of the chaotic map are encoded using RSA (Rivest-Shamir-Adleman) public key encryption. Numerical simulations are carried out to validate the proposed technique.

  4. Assessment of molecular contamination in mask pod

    NASA Astrophysics Data System (ADS)

    Foray, Jean Marie; Dejaune, Patrice; Sergent, Pierre; Gough, Stuart; Cheung, D.; Davenet, Magali; Favre, Arnaud; Rude, C.; Trautmann, T.; Tissier, Michel; Fontaine, H.; Veillerot, M.; Avary, K.; Hollein, I.; Lerit, R.

    2008-04-01

    Context/ study Motivation: Contamination and especially Airbone Molecular Contamination (AMC) is a critical issue for mask material flow with a severe and fairly unpredictable risk of induced contamination and damages especially for 193 nm lithography. It is therefore essential to measure, to understand and then try to reduce AMC in mask environment. Mask material flow was studied in a global approach by a pool of European partners, especially within the frame of European MEDEA+ project, so called "MUSCLE". This paper deals with results and assessment of mask pod environment in term of molecular contamination in a first step, then in a second step preliminary studies to reduce mask pod influence and contamination due to material out gassing. Approach and techniques: A specific assessment of environmental / molecular contamination along the supply chain was performed by all partners. After previous work presented at EMLC 07, further studies were performed on real time contamination measurement pod at different sites locations (including Mask manufacturing site, blank manufacturing sites, IC fab). Studies were linked to the main critical issues: cleaning, storage, handling, materials and processes. Contamination measurement campaigns were carried out along the mask supply chain using specific Adixen analyzer in order to monitor in real time organic contaminants (ppb level) in mask pods. Key results would be presented: VOC, AMC and humidity level on different kinds of mask carriers, impact of basic cleaning on pod outgassing measurement (VOC, NH3), and process influence on pod contamination... In a second step, preliminary specific pod conditioning studies for better pod environment were performed based on Adixen vacuum process. Process influence had been experimentally measured in term of molecular outgassing from mask pods. Different AMC experimental characterization methods had been carried out leading to results on a wide range of organic and inorganic contaminants: by inline techniques based on Adixen humidity, also VOC and organic sensors, together by off-line techniques already used in the extensive previous mask pods benchmark (TD-GCMS & Ionic Chromatography). Humidity and VOC levels from mask carriers had shown significant reduction after Adixen pod conditioning process. Focus had been made on optimized vacuum step (for AMC) after particles carrier cleaning cycle. Based upon these key results new procedures, as well as guidelines for mask carrier cleaning optimization are proposed to improve pod contamination control. Summary results/next steps: This paper reports molecular contamination measurement campaigns performed by a pool of European partners along the mask supply chain. It allows us to investigate, identify and quantify critical molecular contamination in mask pod, as well as VOC and humidity, issues depending on locations, uses, and carrier's type. Preliminary studies highlight initial process solutions for pods conditioning that are being used for short term industrialization and further industrialized.

  5. Temporal masking functions for listeners with real and simulated hearing loss

    PubMed Central

    Desloge, Joseph G.; Reed, Charlotte M.; Braida, Louis D.; Perez, Zachary D.; Delhorne, Lorraine A.

    2011-01-01

    A functional simulation of hearing loss was evaluated in its ability to reproduce the temporal masking functions for eight listeners with mild to severe sensorineural hearing loss. Each audiometric loss was simulated in a group of age-matched normal-hearing listeners through a combination of spectrally-shaped masking noise and multi-band expansion. Temporal-masking functions were obtained in both groups of listeners using a forward-masking paradigm in which the level of a 110-ms masker required to just mask a 10-ms fixed-level probe (5-10 dB SL) was measured as a function of the time delay between the masker offset and probe onset. At each of four probe frequencies (500, 1000, 2000, and 4000 Hz), temporal-masking functions were obtained using maskers that were 0.55, 1.0, and 1.15 times the probe frequency. The slopes and y-intercepts of the masking functions were not significantly different for listeners with real and simulated hearing loss. The y-intercepts were positively correlated with level of hearing loss while the slopes were negatively correlated. The ratio of the slopes obtained with the low-frequency maskers relative to the on-frequency maskers was similar for both groups of listeners and indicated a smaller compressive effect than that observed in normal-hearing listeners. PMID:21877806

  6. Auditory processing efficiency deficits in children with developmental language impairments

    NASA Astrophysics Data System (ADS)

    Hartley, Douglas E. H.; Moore, David R.

    2002-12-01

    The ``temporal processing hypothesis'' suggests that individuals with specific language impairments (SLIs) and dyslexia have severe deficits in processing rapidly presented or brief sensory information, both within the auditory and visual domains. This hypothesis has been supported through evidence that language-impaired individuals have excess auditory backward masking. This paper presents an analysis of masking results from several studies in terms of a model of temporal resolution. Results from this modeling suggest that the masking results can be better explained by an ``auditory efficiency'' hypothesis. If impaired or immature listeners have a normal temporal window, but require a higher signal-to-noise level (poor processing efficiency), this hypothesis predicts the observed small deficits in the simultaneous masking task, and the much larger deficits in backward and forward masking tasks amongst those listeners. The difference in performance on these masking tasks is predictable from the compressive nonlinearity of the basilar membrane. The model also correctly predicts that backward masking (i) is more prone to training effects, (ii) has greater inter- and intrasubject variability, and (iii) increases less with masker level than do other masking tasks. These findings provide a new perspective on the mechanisms underlying communication disorders and auditory masking.

  7. A cluster randomised trial of cloth masks compared with medical masks in healthcare workers

    PubMed Central

    MacIntyre, C Raina; Seale, Holly; Dung, Tham Chi; Hien, Nguyen Tran; Nga, Phan Thi; Chughtai, Abrar Ahmad; Rahman, Bayzidur; Dwyer, Dominic E; Wang, Quanyi

    2015-01-01

    Objective The aim of this study was to compare the efficacy of cloth masks to medical masks in hospital healthcare workers (HCWs). The null hypothesis is that there is no difference between medical masks and cloth masks. Setting 14 secondary-level/tertiary-level hospitals in Hanoi, Vietnam. Participants 1607 hospital HCWs aged ≥18 years working full-time in selected high-risk wards. Intervention Hospital wards were randomised to: medical masks, cloth masks or a control group (usual practice, which included mask wearing). Participants used the mask on every shift for 4 consecutive weeks. Main outcome measure Clinical respiratory illness (CRI), influenza-like illness (ILI) and laboratory-confirmed respiratory virus infection. Results The rates of all infection outcomes were highest in the cloth mask arm, with the rate of ILI statistically significantly higher in the cloth mask arm (relative risk (RR)=13.00, 95% CI 1.69 to 100.07) compared with the medical mask arm. Cloth masks also had significantly higher rates of ILI compared with the control arm. An analysis by mask use showed ILI (RR=6.64, 95% CI 1.45 to 28.65) and laboratory-confirmed virus (RR=1.72, 95% CI 1.01 to 2.94) were significantly higher in the cloth masks group compared with the medical masks group. Penetration of cloth masks by particles was almost 97% and medical masks 44%. Conclusions This study is the first RCT of cloth masks, and the results caution against the use of cloth masks. This is an important finding to inform occupational health and safety. Moisture retention, reuse of cloth masks and poor filtration may result in increased risk of infection. Further research is needed to inform the widespread use of cloth masks globally. However, as a precautionary measure, cloth masks should not be recommended for HCWs, particularly in high-risk situations, and guidelines need to be updated. Trial registration number Australian New Zealand Clinical Trials Registry: ACTRN12610000887077. PMID:25903751

  8. Electrophysiological signals associated with fluency of different levels of processing reveal multiple contributions to recognition memory.

    PubMed

    Li, Bingbing; Taylor, Jason R; Wang, Wei; Gao, Chuanji; Guo, Chunyan

    2017-08-01

    Processing fluency appears to influence recognition memory judgements, and the manipulation of fluency, if misattributed to an effect of prior exposure, can result in illusory memory. Although it is well established that fluency induced by masked repetition priming leads to increased familiarity, manipulations of conceptual fluency have produced conflicting results, variously affecting familiarity or recollection. Some recent studies have found that masked conceptual priming increases correct recollection (Taylor & Henson, 2012), and the magnitude of this behavioural effect correlates with analogous fMRI BOLD priming effects in brain regions associated with recollection (Taylor, Buratto, & Henson, 2013). However, the neural correlates and time-courses of masked repetition and conceptual priming were not compared directly in previous studies. The present study used event-related potentials (ERPs) to identify and compare the electrophysiological correlates of masked repetition and conceptual priming and investigate how they contribute to recognition memory. Behavioural results were consistent with previous studies: Repetition primes increased familiarity, whereas conceptual primes increased correct recollection. Masked repetition and conceptual priming also decreased the latency of late parietal component (LPC). Masked repetition priming was associated with an early P200 effect and a later parietal maximum N400 effect, whereas masked conceptual priming was only associated with a central-parietal maximum N400 effect. In addition, the topographic distributions of the N400 repetition priming and conceptual priming effects were different. These results suggest that fluency at different levels of processing is associated with different ERP components, and contributes differentially to subjective recognition memory experiences. Copyright © 2017 Elsevier Inc. All rights reserved.

  9. Masking functions and fixed-signal functions for low-level 1000-Hz tones.

    PubMed

    Shepherd, Daniel; Hautus, Michael J; Jesteadt, Walt

    2013-06-01

    Masking functions and fixed-signal functions were constructed using a narrow range of pedestal intensities for 10-ms, 1000-Hz gated tones. Data from three experiments agreed with previously reported data, clearly demonstrating negative masking and the pedestal effect. The data extend earlier findings by showing (1) the resilience of the pedestal effect when a background noise masker is introduced; (2) a possible indifference of the fixed-signal function to stimulus duration; (3) the ability of a set of psychometric functions to produce both masking and fixed-signal functions; (4) depending on method, the impact of unit choice on the interpretation of both the pedestal effect and negative masking data. Results are discussed in relation to current psychophysical models, and suggest that accounting for the auditory system's sensitivity to differences in low-level sounds remains a challenge.

  10. Emergency face-mask removal effectiveness: a comparison of traditional and nontraditional football helmet face-mask attachment systems.

    PubMed

    Swartz, Erik E; Belmore, Keith; Decoster, Laura C; Armstrong, Charles W

    2010-01-01

    Football helmet face-mask attachment design changes might affect the effectiveness of face-mask removal. To compare the efficiency of face-mask removal between newly designed and traditional football helmets. Controlled laboratory study. Applied biomechanics laboratory. Twenty-five certified athletic trainers. The independent variable was face-mask attachment system on 5 levels: (1) Revolution IQ with Quick Release (QR), (2) Revolution IQ with Quick Release hardware altered (QRAlt), (3) traditional (Trad), (4) traditional with hardware altered (TradAlt), and (5) ION 4D (ION). Participants removed face masks using a cordless screwdriver with a back-up cutting tool or only the cutting tool for the ION. Investigators altered face-mask hardware to unexpectedly challenge participants during removal for traditional and Revolution IQ helmets. Participants completed each condition twice in random order and were blinded to hardware alteration. Removal success, removal time, helmet motion, and rating of perceived exertion (RPE). Time and 3-dimensional helmet motion were recorded. If the face mask remained attached at 3 minutes, the trial was categorized as unsuccessful. Participants rated each trial for level of difficulty (RPE). We used repeated-measures analyses of variance (α  =  .05) with follow-up comparisons to test for differences. Removal success was 100% (48 of 48) for QR, Trad, and ION; 97.9% (47 of 48) for TradAlt; and 72.9% (35 of 48) for QRAlt. Differences in time for face-mask removal were detected (F(4,20)  =  48.87, P  =  .001), with times ranging from 33.96 ± 14.14 seconds for QR to 99.22 ± 20.53 seconds for QRAlt. Differences were found in range of motion during face-mask removal (F(4,20)  =  16.25, P  =  .001), with range of motion from 10.10° ± 3.07° for QR to 16.91° ± 5.36° for TradAlt. Differences also were detected in RPE during face-mask removal (F(4,20)  =  43.20, P  =  .001), with participants reporting average perceived difficulty ranging from 1.44 ± 1.19 for QR to 3.68 ± 1.70 for TradAlt. The QR and Trad trials resulted in superior results. When trials required cutting loop straps, results deteriorated.

  11. Ensuring Confidentiality of Geocoded Health Data: Assessing Geographic Masking Strategies for Individual-Level Data.

    PubMed

    Zandbergen, Paul A

    2014-01-01

    Public health datasets increasingly use geographic identifiers such as an individual's address. Geocoding these addresses often provides new insights since it becomes possible to examine spatial patterns and associations. Address information is typically considered confidential and is therefore not released or shared with others. Publishing maps with the locations of individuals, however, may also breach confidentiality since addresses and associated identities can be discovered through reverse geocoding. One commonly used technique to protect confidentiality when releasing individual-level geocoded data is geographic masking. This typically consists of applying a certain amount of random perturbation in a systematic manner to reduce the risk of reidentification. A number of geographic masking techniques have been developed as well as methods to quantity the risk of reidentification associated with a particular masking method. This paper presents a review of the current state-of-the-art in geographic masking, summarizing the various methods and their strengths and weaknesses. Despite recent progress, no universally accepted or endorsed geographic masking technique has emerged. Researchers on the other hand are publishing maps using geographic masking of confidential locations. Any researcher publishing such maps is advised to become familiar with the different masking techniques available and their associated reidentification risks.

  12. Recovery from forward masking in cochlear implant listeners depends on stimulation mode, level, and electrode location

    PubMed Central

    Chatterjee, Monita; Kulkarni, Aditya M.

    2017-01-01

    Psychophysical recovery from forward masking was measured in adult cochlear implant users of CochlearTM and Advanced BionicsTM devices, in monopolar and in focused (bipolar and tripolar) stimulation modes, at four electrode sites across the arrays, and at two levels (loudness balanced across modes and electrodes). Results indicated a steeper psychophysical recovery from forward masking in monopolar over bipolar and tripolar modes, modified by differential effects of electrode and level. The interactions between factors varied somewhat across devices. It is speculated that psychophysical recovery from forward masking may be driven by different populations of neurons in the different modes, with a broader stimulation pattern resulting in a greater likelihood of response by healthier and/or faster-recovering neurons within the stimulated population. If a more rapid recovery from prior stimulation reflects responses of neurons not necessarily close to the activating site, the spectral pattern of the incoming acoustic signal may be distorted. These results have implications for speech processor implementations using different degrees of focusing of the electric field. The primary differences in the shape of the recovery function were observed in the earlier portion (between 2 and 45 ms) of recovery, which is significant in terms of the speech envelope. PMID:28682084

  13. A cluster randomised trial of cloth masks compared with medical masks in healthcare workers.

    PubMed

    MacIntyre, C Raina; Seale, Holly; Dung, Tham Chi; Hien, Nguyen Tran; Nga, Phan Thi; Chughtai, Abrar Ahmad; Rahman, Bayzidur; Dwyer, Dominic E; Wang, Quanyi

    2015-04-22

    The aim of this study was to compare the efficacy of cloth masks to medical masks in hospital healthcare workers (HCWs). The null hypothesis is that there is no difference between medical masks and cloth masks. 14 secondary-level/tertiary-level hospitals in Hanoi, Vietnam. 1607 hospital HCWs aged ≥18 years working full-time in selected high-risk wards. Hospital wards were randomised to: medical masks, cloth masks or a control group (usual practice, which included mask wearing). Participants used the mask on every shift for 4 consecutive weeks. Clinical respiratory illness (CRI), influenza-like illness (ILI) and laboratory-confirmed respiratory virus infection. The rates of all infection outcomes were highest in the cloth mask arm, with the rate of ILI statistically significantly higher in the cloth mask arm (relative risk (RR)=13.00, 95% CI 1.69 to 100.07) compared with the medical mask arm. Cloth masks also had significantly higher rates of ILI compared with the control arm. An analysis by mask use showed ILI (RR=6.64, 95% CI 1.45 to 28.65) and laboratory-confirmed virus (RR=1.72, 95% CI 1.01 to 2.94) were significantly higher in the cloth masks group compared with the medical masks group. Penetration of cloth masks by particles was almost 97% and medical masks 44%. This study is the first RCT of cloth masks, and the results caution against the use of cloth masks. This is an important finding to inform occupational health and safety. Moisture retention, reuse of cloth masks and poor filtration may result in increased risk of infection. Further research is needed to inform the widespread use of cloth masks globally. However, as a precautionary measure, cloth masks should not be recommended for HCWs, particularly in high-risk situations, and guidelines need to be updated. Australian New Zealand Clinical Trials Registry: ACTRN12610000887077. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://group.bmj.com/group/rights-licensing/permissions.

  14. Object Substitution Masking Induced by Illusory Masks: Evidence for Higher Object-Level Locus of Interference

    ERIC Educational Resources Information Center

    Hirose, Nobuyuki; Osaka, Naoyuki

    2009-01-01

    A briefly presented target can be rendered invisible by a lingering sparse mask that does not even touch it. This form of visual backward masking, called object substitution masking, is thought to occur at the object level of processing. However, it remains unclear whether object-level interference alone produces substitution masking because…

  15. The Neural Substrate for Binaural Masking Level Differences in the Auditory Cortex

    PubMed Central

    Gilbert, Heather J.; Krumbholz, Katrin; Palmer, Alan R.

    2015-01-01

    The binaural masking level difference (BMLD) is a phenomenon whereby a signal that is identical at each ear (S0), masked by a noise that is identical at each ear (N0), can be made 12–15 dB more detectable by inverting the waveform of either the tone or noise at one ear (Sπ, Nπ). Single-cell responses to BMLD stimuli were measured in the primary auditory cortex of urethane-anesthetized guinea pigs. Firing rate was measured as a function of signal level of a 500 Hz pure tone masked by low-passed white noise. Responses were similar to those reported in the inferior colliculus. At low signal levels, the response was dominated by the masker. At higher signal levels, firing rate either increased or decreased. Detection thresholds for each neuron were determined using signal detection theory. Few neurons yielded measurable detection thresholds for all stimulus conditions, with a wide range in thresholds. However, across the entire population, the lowest thresholds were consistent with human psychophysical BMLDs. As in the inferior colliculus, the shape of the firing-rate versus signal-level functions depended on the neurons' selectivity for interaural time difference. Our results suggest that, in cortex, BMLD signals are detected from increases or decreases in the firing rate, consistent with predictions of cross-correlation models of binaural processing and that the psychophysical detection threshold is based on the lowest neural thresholds across the population. PMID:25568115

  16. A study of special care dental patient preference toward choice of mask and visor use by dental clinicians.

    PubMed

    Emanuel, Robert; Corcoran, Richard; Cass, Helen

    2017-07-01

    Do patients have a preference for the clinician's choice of face protection (visor or mask), and can this make a difference to the patient's feelings of anxiety? In a normative sample (n = 72) of patients from Special Care Dentistry, different combinations of face protection were studied to see whether the patients clearly preferred one type over another, and whether that was related to the levels of anxiety they suffered, based on the modified dental anxiety scale. The majority of patients, 68% had the visor only as their first choice of face protection. This was followed by 22% having the mask only as their first choice and 10% having the visor and mask combination as their first choice. Patients with higher anxiety levels were more likely to believe that the type of face protection worn by the dentist would affect their levels of anxiety. The patients preferred the visor only option. As the level of anxiety rose, so did the percentage of patients that felt the style of protection worn by the dentist would affect their level of anxiety. The comments from patients referred to the benefit of nonverbal communication offered by the visor. © 2017 Special Care Dentistry Association and Wiley Periodicals, Inc.

  17. A masking level difference due to harmonicity.

    PubMed

    Treurniet, W C; Boucher, D R

    2001-01-01

    The role of harmonicity in masking was studied by comparing the effect of harmonic and inharmonic maskers on the masked thresholds of noise probes using a three-alternative, forced-choice method. Harmonic maskers were created by selecting sets of partials from a harmonic series with an 88-Hz fundamental and 45 consecutive partials. Inharmonic maskers differed in that the partial frequencies were perturbed to nearby values that were not integer multiples of the fundamental frequency. Average simultaneous-masked thresholds were as much as 10 dB lower with the harmonic masker than with the inharmonic masker, and this difference was unaffected by masker level. It was reduced or eliminated when the harmonic partials were separated by more than 176 Hz, suggesting that the effect is related to the extent to which the harmonics are resolved by auditory filters. The threshold difference was not observed in a forward-masking experiment. Finally, an across-channel mechanism was implicated when the threshold difference was found between a harmonic masker flanked by harmonic bands and a harmonic masker flanked by inharmonic bands. A model developed to explain the observed difference recognizes that an auditory filter output envelope is modulated when the filter passes two or more sinusoids, and that the modulation rate depends on the differences among the input frequencies. For a harmonic masker, the frequency differences of adjacent partials are identical, and all auditory filters have the same dominant modulation rate. For an inharmonic masker, however, the frequency differences are not constant and the envelope modulation rate varies across filters. The model proposes that a lower variability facilitates detection of a probe-induced change in the variability, thus accounting for the masked threshold difference. The model was supported by significantly improved predictions of observed thresholds when the predictor variables included envelope modulation rate variance measured using simulated auditory filters.

  18. A comparison of the capacity of ice hockey goaltender masks for the protection from puck impacts.

    PubMed

    Nur, Sarah; Kendall, Marshall; Clark, J Michio; Hoshizaki, T Blaine

    2015-01-01

    Goaltenders in ice hockey are the only players that are on the ice for the entire game. Their position exposes them to impacts from collisions with other players, falls to the ice, and puck impacts. In competitive ice hockey leagues, head injuries resulting from puck impacts have been reported with some cases resulting in ending the player's career. Considerable research has been conducted to assess the performance of hockey helmets; however, few have assessed the performance of goaltenders' masks. The purpose of this study was to compare the capacity of four goaltenders' masks for the protection from puck impact as measured by head acceleration and peak force. A Hybrid III headform was fitted with four different goaltender masks and impacted with a hockey puck in three locations at 25 m/s. The masks were found to vary in the level of protection they offered as the mask with the thickest liner resulted in lower forces than the thinnest mask for side impacts; however, the thinnest mask resulted in the lowest force for front impacts. Despite performance differences at specific locations, no one mask proved to be superior as peak acceleration and peak force values did not exceed the thresholds necessary for concussion.

  19. The binaural masking level difference: cortical correlates persist despite severe brain stem atrophy in progressive supranuclear palsy

    PubMed Central

    Rowe, James B.; Ghosh, Boyd C. P.; Carlyon, Robert P.; Plack, Christopher J.; Gockel, Hedwig E.

    2014-01-01

    Under binaural listening conditions, the detection of target signals within background masking noise is substantially improved when the interaural phase of the target differs from that of the masker. Neural correlates of this binaural masking level difference (BMLD) have been observed in the inferior colliculus and temporal cortex, but it is not known whether degeneration of the inferior colliculus would result in a reduction of the BMLD in humans. We used magnetoencephalography to examine the BMLD in 13 healthy adults and 13 patients with progressive supranuclear palsy (PSP). PSP is associated with severe atrophy of the upper brain stem, including the inferior colliculus, confirmed by voxel-based morphometry of structural MRI. Stimuli comprised in-phase sinusoidal tones presented to both ears at three levels (high, medium, and low) masked by in-phase noise, which rendered the low-level tone inaudible. Critically, the BMLD was measured using a low-level tone presented in opposite phase across ears, making it audible against the noise. The cortical waveforms from bilateral auditory sources revealed significantly larger N1m peaks for the out-of-phase low-level tone compared with the in-phase low-level tone, for both groups, indicating preservation of early cortical correlates of the BMLD in PSP. In PSP a significant delay was observed in the onset of the N1m deflection and the amplitude of the P2m was reduced, but these differences were not restricted to the BMLD condition. The results demonstrate that although PSP causes subtle auditory deficits, binaural processing can survive the presence of significant damage to the upper brain stem. PMID:25231610

  20. The binaural masking level difference: cortical correlates persist despite severe brain stem atrophy in progressive supranuclear palsy.

    PubMed

    Hughes, Laura E; Rowe, James B; Ghosh, Boyd C P; Carlyon, Robert P; Plack, Christopher J; Gockel, Hedwig E

    2014-12-15

    Under binaural listening conditions, the detection of target signals within background masking noise is substantially improved when the interaural phase of the target differs from that of the masker. Neural correlates of this binaural masking level difference (BMLD) have been observed in the inferior colliculus and temporal cortex, but it is not known whether degeneration of the inferior colliculus would result in a reduction of the BMLD in humans. We used magnetoencephalography to examine the BMLD in 13 healthy adults and 13 patients with progressive supranuclear palsy (PSP). PSP is associated with severe atrophy of the upper brain stem, including the inferior colliculus, confirmed by voxel-based morphometry of structural MRI. Stimuli comprised in-phase sinusoidal tones presented to both ears at three levels (high, medium, and low) masked by in-phase noise, which rendered the low-level tone inaudible. Critically, the BMLD was measured using a low-level tone presented in opposite phase across ears, making it audible against the noise. The cortical waveforms from bilateral auditory sources revealed significantly larger N1m peaks for the out-of-phase low-level tone compared with the in-phase low-level tone, for both groups, indicating preservation of early cortical correlates of the BMLD in PSP. In PSP a significant delay was observed in the onset of the N1m deflection and the amplitude of the P2m was reduced, but these differences were not restricted to the BMLD condition. The results demonstrate that although PSP causes subtle auditory deficits, binaural processing can survive the presence of significant damage to the upper brain stem. Copyright © 2014 the American Physiological Society.

  1. Ensuring Confidentiality of Geocoded Health Data: Assessing Geographic Masking Strategies for Individual-Level Data

    PubMed Central

    Zandbergen, Paul A.

    2014-01-01

    Public health datasets increasingly use geographic identifiers such as an individual's address. Geocoding these addresses often provides new insights since it becomes possible to examine spatial patterns and associations. Address information is typically considered confidential and is therefore not released or shared with others. Publishing maps with the locations of individuals, however, may also breach confidentiality since addresses and associated identities can be discovered through reverse geocoding. One commonly used technique to protect confidentiality when releasing individual-level geocoded data is geographic masking. This typically consists of applying a certain amount of random perturbation in a systematic manner to reduce the risk of reidentification. A number of geographic masking techniques have been developed as well as methods to quantity the risk of reidentification associated with a particular masking method. This paper presents a review of the current state-of-the-art in geographic masking, summarizing the various methods and their strengths and weaknesses. Despite recent progress, no universally accepted or endorsed geographic masking technique has emerged. Researchers on the other hand are publishing maps using geographic masking of confidential locations. Any researcher publishing such maps is advised to become familiar with the different masking techniques available and their associated reidentification risks. PMID:26556417

  2. The total face mask is more comfortable than the oronasal mask in noninvasive ventilation but is not associated with improved outcome.

    PubMed

    Chacur, Fernando Hauaji; Vilella Felipe, Luis Marcelo; Fernandes, Cintia Gonçalves; Lazzarini, Luiz Claudio Oliveira

    2011-01-01

    Noninvasive positive-pressure ventilation (NPPV) is commonly used to improve ventilation and oxygenation and avoid endotracheal intubation and mechanical ventilation. Although clinically indicated, most patients fail to use NPPV due to mask intolerance. A total face mask was designed to increase compliance, but whether this translates into better outcome (improvement in clinical and blood gas parameters and less intubation) is unknown. We compared the evolution of the clinical parameters, blood gases, levels of ventilatory support and rate of endotracheal intubation using the total face mask or the traditional oronasal mask during NPPV. A total of 60 patients were randomized to use either mask during NPPV. The clinical and laboratory parameters, as well as the level of ventilatory support were recorded at different intervals in both groups for up to 6 h. In addition, the tolerance for each mask and the need for endotracheal intubation were compared. Patients tolerated the total face mask significantly better (p = 0.0010) and used NPPV for a longer time (p = 0.0017) when compared with the oronasal mask. Just 1 patient switched to the total face mask because of intolerance. Although better tolerated, the rate of endotracheal intubation was similar in both groups (p = 0.4376), as was the clinical and laboratory evolution. The total face mask was more comfortable, allowing the patients to tolerate NPPV longer; however, these accomplishments did not translate into a better outcome. Due to its comfort, the total face mask should be available, at least as an option, in units where NPPVs are routinely applied. Copyright © 2011 S. Karger AG, Basel.

  3. Emergency Face-Mask Removal Effectiveness: A Comparison of Traditional and Nontraditional Football Helmet Face-Mask Attachment Systems

    PubMed Central

    Swartz, Erik E.; Belmore, Keith; Decoster, Laura C.; Armstrong, Charles W.

    2010-01-01

    Abstract Context: Football helmet face-mask attachment design changes might affect the effectiveness of face-mask removal. Objective: To compare the efficiency of face-mask removal between newly designed and traditional football helmets. Design: Controlled laboratory study. Setting: Applied biomechanics laboratory. Participants: Twenty-five certified athletic trainers. Intervention(s): The independent variable was face-mask attachment system on 5 levels: (1) Revolution IQ with Quick Release (QR), (2) Revolution IQ with Quick Release hardware altered (QRAlt), (3) traditional (Trad), (4) traditional with hardware altered (TradAlt), and (5) ION 4D (ION). Participants removed face masks using a cordless screwdriver with a back-up cutting tool or only the cutting tool for the ION. Investigators altered face-mask hardware to unexpectedly challenge participants during removal for traditional and Revolution IQ helmets. Participants completed each condition twice in random order and were blinded to hardware alteration. Main Outcome Measure(s): Removal success, removal time, helmet motion, and rating of perceived exertion (RPE). Time and 3-dimensional helmet motion were recorded. If the face mask remained attached at 3 minutes, the trial was categorized as unsuccessful. Participants rated each trial for level of difficulty (RPE). We used repeated-measures analyses of variance (α  =  .05) with follow-up comparisons to test for differences. Results: Removal success was 100% (48 of 48) for QR, Trad, and ION; 97.9% (47 of 48) for TradAlt; and 72.9% (35 of 48) for QRAlt. Differences in time for face-mask removal were detected (F4,20  =  48.87, P  =  .001), with times ranging from 33.96 ± 14.14 seconds for QR to 99.22 ± 20.53 seconds for QRAlt. Differences were found in range of motion during face-mask removal (F4,20  =  16.25, P  =  .001), with range of motion from 10.10° ± 3.07° for QR to 16.91° ± 5.36° for TradAlt. Differences also were detected in RPE during face-mask removal (F4,20  =  43.20, P  =  .001), with participants reporting average perceived difficulty ranging from 1.44 ± 1.19 for QR to 3.68 ± 1.70 for TradAlt. Conclusions: The QR and Trad trials resulted in superior results. When trials required cutting loop straps, results deteriorated. PMID:21062179

  4. Intact figure-ground segmentation in schizophrenia.

    PubMed

    Herzog, Michael H; Kopmann, Sabine; Brand, Andreas

    2004-11-30

    As revealed by backward masking studies, schizophrenic patients show strong impairments of early visual processing. However, the underlying temporal mechanisms are not yet well understood. To shed light on the exact timing of these deficits, we employed a paradigm in which two masks follow each other. We investigated 16 medicated schizophrenic patients and a matched group of 14 controls with a new backward masking technique, shine-through. In accordance with other masking studies, schizophrenic patients require a dramatically longer processing time to reach a predefined performance level compared with healthy subjects. However, patients are surprisingly sensitive to subtle differences in the timing of the two masks, revealing good temporal resolution. This good temporal resolution indicates intact and fast perceptual grouping and figure-ground segmentation in spite of high susceptibility to masking procedures in schizophrenia.

  5. Autonomic Nervous System Responses During Perception of Masked Speech may Reflect Constructs other than Subjective Listening Effort

    PubMed Central

    Francis, Alexander L.; MacPherson, Megan K.; Chandrasekaran, Bharath; Alvar, Ann M.

    2016-01-01

    Typically, understanding speech seems effortless and automatic. However, a variety of factors may, independently or interactively, make listening more effortful. Physiological measures may help to distinguish between the application of different cognitive mechanisms whose operation is perceived as effortful. In the present study, physiological and behavioral measures associated with task demand were collected along with behavioral measures of performance while participants listened to and repeated sentences. The goal was to measure psychophysiological reactivity associated with three degraded listening conditions, each of which differed in terms of the source of the difficulty (distortion, energetic masking, and informational masking), and therefore were expected to engage different cognitive mechanisms. These conditions were chosen to be matched for overall performance (keywords correct), and were compared to listening to unmasked speech produced by a natural voice. The three degraded conditions were: (1) Unmasked speech produced by a computer speech synthesizer, (2) Speech produced by a natural voice and masked byspeech-shaped noise and (3) Speech produced by a natural voice and masked by two-talker babble. Masked conditions were both presented at a -8 dB signal to noise ratio (SNR), a level shown in previous research to result in comparable levels of performance for these stimuli and maskers. Performance was measured in terms of proportion of key words identified correctly, and task demand or effort was quantified subjectively by self-report. Measures of psychophysiological reactivity included electrodermal (skin conductance) response frequency and amplitude, blood pulse amplitude and pulse rate. Results suggest that the two masked conditions evoked stronger psychophysiological reactivity than did the two unmasked conditions even when behavioral measures of listening performance and listeners’ subjective perception of task demand were comparable across the three degraded conditions. PMID:26973564

  6. A further test of the linearity of temporal summation in forward masking.

    PubMed

    Plack, Christopher J; Carcagno, Samuele; Oxenham, Andrew J

    2007-10-01

    An experiment tested the hypothesis that the masking effects of two nonoverlapping forward maskers are summed linearly over time. First, the levels of individual noise maskers required to mask a brief 4-kHz signal presented at 10-, 20-, 30-, or 40-dB sensation level (SL) were found. The hypothesis predicts that a combination of the first masker presented at the level required to mask the 10-dB SL signal and the second masker presented at the level required to mask the 20-dB SL signal, should produce the same amount of masking as the converse situation (i.e., the first masker presented at the level required to mask the 20-dB SL signal and the second masker presented at the level required to mask the 10-dB SL signal), and similarly for the 30- and 40-dB SL signals. The results were consistent with the predictions.

  7. Flavored Anesthetic Masks for Inhalational Induction in Children.

    PubMed

    Gupta, Aakriti; Mathew, Preethy Joseph; Bhardwaj, Neerja

    2017-10-01

    To evaluate the clinical efficacy of masking the odor of inhalational agents using fruit flavors on the anxiety behavior and compliance of children for inhalational induction. A prospective randomized double blind, placebo controlled study was conducted on 60 unpremedicated children in the age group of 4-12 y. Thirty children received anesthetic masks smeared with a flavor of child's choice while the other 30 children were induced using masks without flavor. Anxiety was assessed using modified Yale Pre-operative Anxiety Scale (mYPAS) in the pre-op room and during inhalational induction. Mask acceptance was graded by Induction Compliance Checklist (ICC). The cost-effectiveness of flavored anesthetic masks was compared to that of commercially available pre-scented masks. The baseline anxiety in the two groups was comparable. The number of children demonstrating high levels of anxiety at anesthetic induction was similar in flavored and non-flavored mask groups (p 0.45). The compliance to mask induction was also equally good (p 0.99). The authors found significant difference in the cost of flavored mask (INR 56.45 per mask) as compared to commercially available pre-scented masks (INR 660 per mask). The authors observed a placebo effect that reduced the pre-op anxiety in the control group which probably made the quality of induction equivalent with flavored and non-flavored masks. Therefore, using a flavored anesthetic mask is cost-effective than using a commercially available pre-scented mask.

  8. Clinical applications of selected binaural effects.

    PubMed

    Noffsinger, D

    1982-01-01

    Examination was made of the behaviors exhibited on selected binaural tasks by 556 persons with diagnosed peripheral hearing loss or central nervous system damage. The tasks used included loudness balancing (LB), intracranial midline imaging (MI), masking level differences (MLD), and binaural beats (BB). The methods used were chosen for their clinical utility. Loudness balancing and midline imaging were of the most diagnostic value when hearing loss was present. Masking level differences were best at detecting pathology which did not produce hearing loss. None of the techniques were sensitive to cortical damage.

  9. TMS effects on subjective and objective measures of vision: stimulation intensity and pre- versus post-stimulus masking.

    PubMed

    de Graaf, Tom A; Cornelsen, Sonja; Jacobs, Christianne; Sack, Alexander T

    2011-12-01

    Transcranial magnetic stimulation (TMS) can be used to mask visual stimuli, disrupting visual task performance or preventing visual awareness. While TMS masking studies generally fix stimulation intensity, we hypothesized that varying the intensity of TMS pulses in a masking paradigm might inform several ongoing debates concerning TMS disruption of vision as measured subjectively versus objectively, and pre-stimulus (forward) versus post-stimulus (backward) TMS masking. We here show that both pre-stimulus TMS pulses and post-stimulus TMS pulses could strongly mask visual stimuli. We found no dissociations between TMS effects on the subjective and objective measures of vision for any masking window or intensity, ruling out the option that TMS intensity levels determine whether dissociations between subjective and objective vision are obtained. For the post-stimulus time window particularly, we suggest that these data provide new constraints for (e.g. recurrent) models of vision and visual awareness. Finally, our data are in line with the idea that pre-stimulus masking operates differently from conventional post-stimulus masking. Copyright © 2011 Elsevier Inc. All rights reserved.

  10. Are root letters compulsory for lexical access in Semitic languages? The case of masked form-priming in Arabic.

    PubMed

    Perea, Manuel; Mallouh, Reem Abu; Carreiras, Manuel

    2014-09-01

    Do Semitic and Indo-European languages differ at a qualitative level? Recently, it has been claimed that lexical space in Semitic languages (e.g., Hebrew, Arabic) is mainly determined by morphological constraints, while lexical space in Indo-European languages is mainly determined by orthographic constraints (Frost, Kugler, Deutsch, & Forster, 2005). One of the key findings supporting the qualitative difference between Semitic and Indo-European languages is the absence of masked form priming in Hebrew/Arabic with productive words. Here we examined whether masked form priming occurs in Arabic words when one of the letters from the productive root is replaced in the prime stimulus by another letter. Results showed a significant masked form priming effect with the lexical decision task in three experiments (including yes/no, go/no-go, and sandwich priming), to a similar degree to that reported in previous research with Indo-European languages. These data support the view that the processing of word forms in Semitic vs. Indo-European languages differs more at a quantitative than at a qualitative level. Copyright © 2014 Elsevier B.V. All rights reserved.

  11. The subjective importance of noise spectral content

    NASA Astrophysics Data System (ADS)

    Baxter, Donald; Phillips, Jonathan; Denman, Hugh

    2014-01-01

    This paper presents secondary Standard Quality Scale (SQS2) rankings in overall quality JNDs for a subjective analysis of the 3 axes of noise, amplitude, spectral content, and noise type, based on the ISO 20462 softcopy ruler protocol. For the initial pilot study, a Python noise simulation model was created to generate the matrix of noise masks for the softcopy ruler base images with different levels of noise, different low pass filter noise bandwidths and different band pass filter center frequencies, and 3 different types of noise: luma only, chroma only, and luma and chroma combined. Based on the lessons learned, the full subjective experiment, involving 27 observers from Google, NVIDIA and STMicroelectronics was modified to incorporate a wider set of base image scenes, and the removal of band pass filtered noise masks to ease observer fatigue. Good correlation was observed with the Aptina subjective noise study. The absence of tone mapping in the noise simulation model visibly reduced the contrast at high levels of noise, due to the clipping of the high levels of noise near black and white. Under the 34-inch viewing distance, no significant difference was found between the luma only noise masks and the combined luma and chroma noise masks. This was not the intuitive expectation. Two of the base images with large uniform areas, `restaurant' and `no parking', were found to be consistently more sensitive to noise than the texture rich scenes. Two key conclusions are (1) there are fundamentally different sensitivities to noise on a flat patch versus noise in real images and (2) magnification of an image accentuates visual noise in a way that is non-representative of typical noise reduction algorithms generating the same output frequency. Analysis of our experimental noise masks applied to a synthetic Macbeth ColorChecker Chart confirmed the color-dependent nature of the visibility of luma and chroma noise.

  12. Modeling off-frequency binaural masking for short- and long-duration signals.

    PubMed

    Nitschmann, Marc; Yasin, Ifat; Henning, G Bruce; Verhey, Jesko L

    2017-08-01

    Experimental binaural masking-pattern data are presented together with model simulations for 12- and 600-ms signals. The masker was a diotic 11-Hz wide noise centered on 500 Hz. The tonal signal was presented either diotically or dichotically (180° interaural phase difference) with frequencies ranging from 400 to 600 Hz. The results and the modeling agree with previous data and hypotheses; simulations with a binaural model sensitive to monaural modulation cues show that the effect of duration on off-frequency binaural masking-level differences is mainly a result of modulation cues which are only available in the monaural detection of long signals.

  13. Overlay improvement by exposure map based mask registration optimization

    NASA Astrophysics Data System (ADS)

    Shi, Irene; Guo, Eric; Chen, Ming; Lu, Max; Li, Gordon; Li, Rivan; Tian, Eric

    2015-03-01

    Along with the increased miniaturization of semiconductor electronic devices, the design rules of advanced semiconductor devices shrink dramatically. [1] One of the main challenges of lithography step is the layer-to-layer overlay control. Furthermore, DPT (Double Patterning Technology) has been adapted for the advanced technology node like 28nm and 14nm, corresponding overlay budget becomes even tighter. [2][3] After the in-die mask registration (pattern placement) measurement is introduced, with the model analysis of a KLA SOV (sources of variation) tool, it's observed that registration difference between masks is a significant error source of wafer layer-to-layer overlay at 28nm process. [4][5] Mask registration optimization would highly improve wafer overlay performance accordingly. It was reported that a laser based registration control (RegC) process could be applied after the pattern generation or after pellicle mounting and allowed fine tuning of the mask registration. [6] In this paper we propose a novel method of mask registration correction, which can be applied before mask writing based on mask exposure map, considering the factors of mask chip layout, writing sequence, and pattern density distribution. Our experiment data show if pattern density on the mask keeps at a low level, in-die mask registration residue error in 3sigma could be always under 5nm whatever blank type and related writer POSCOR (position correction) file was applied; it proves random error induced by material or equipment would occupy relatively fixed error budget as an error source of mask registration. On the real production, comparing the mask registration difference through critical production layers, it could be revealed that registration residue error of line space layers with higher pattern density is always much larger than the one of contact hole layers with lower pattern density. Additionally, the mask registration difference between layers with similar pattern density could also achieve under 5nm performance. We assume mask registration excluding random error is mostly induced by charge accumulation during mask writing, which may be calculated from surrounding exposed pattern density. Multi-loading test mask registration result shows that with x direction writing sequence, mask registration behavior in x direction is mainly related to sequence direction, but mask registration in y direction would be highly impacted by pattern density distribution map. It proves part of mask registration error is due to charge issue from nearby environment. If exposure sequence is chip by chip for normal multi chip layout case, mask registration of both x and y direction would be impacted analogously, which has also been proved by real data. Therefore, we try to set up a simple model to predict the mask registration error based on mask exposure map, and correct it with the given POSCOR (position correction) file for advanced mask writing if needed.

  14. Performance Comparisons of Jet and Mesh Nebulizers Using Different Interfaces in Simulated Spontaneously Breathing Adults and Children.

    PubMed

    Ari, Arzu; de Andrade, Armele Dornelas; Sheard, Meryl; AlHamad, Bshayer; Fink, James B

    2015-08-01

    Different types of nebulizers and interfaces are used for the treatment of adults and children with pulmonary diseases. The purpose of this study was to determine the efficiency of a mesh nebulizer (MN) with a proprietary adapter and a jet nebulizer (JN) under different configurations in adult and pediatric models of spontaneous breathing. We hypothesize that delivery efficiency of JN and MN will differ depending on the interface used during aerosol therapy in simulated spontaneously breathing adult and pediatric models. While we expect that aerosol delivery with JN will be less efficient than MN, we also hypothesize that lung deposition obtained with the adult lung model will be more than that with the pediatric lung model in all conditions tested in this study. A lung model using a teaching manikin connected to a sinusoidal pump via a collecting filter at the level of the bronchi simulating a spontaneously breathing adult (Vt 500 mL, RR 15 bpm, I:E ratio 1:2) or pediatric patient (Vt 150 mL, RR 25 bpm, I:E ratio 1:2). Albuterol sulfate (2.5 mg/3 mL) was aerosolized with JN (Mistymax 10, Airlife) or MN (Aerogen Solo(®), Aerogen) with the Adapter (Aerogen Solo(®) Adapter, Aerogen Ltd, Galway, Ireland) using mouthpiece, aerosol mask, and valved-mask in adults and the dragon mask, aerosol mask, and valved-mask in pediatrics (n=3). The Adapter, specifically designed for MN, was attached to all the interfaces used in this study with supplemental oxygen of 2 lpm, and in addition, the MP was tested with no additional flow in the adult model. The JN was driven with 10 lpm based on the manufacturer's label. Drug was eluted from the filter and analyzed via spectrophotometry. Descriptive statistics, dependent t-test and one-way analysis of variance were used for data analysis. Significant level was set at 0.05. In adults, delivery efficiency of JN with the valved mask was significantly greater than that with the aerosol mask (p=0.01). Aerosol delivery of JN with the mouthpiece was not statistically significant from the valved mask (p=0.123) and the aerosol mask (p=0.193). Drug delivery with MN with mouthpiece (15.42±1.4%) and valved-mask (15.15±1.1%) was greater than the open aerosol mask (7.54±0.39%; p=0.0001) in the adult lung model. With no flow mouthpiece delivery increased>2 fold (34.9±3.1%; p=.0001) compared to use of 2 lpm of flow. Using the JN with the pediatric model deposition with valved-mask (5.3±0.8%), dragon mask (4.7±0.9%), and aerosol mask (4.1±0.3%) were similar (p>0.05); while drug delivery with MN via valved-mask (11.1±0.7%) was greater than the dragon mask (6.44±0.3%; p=0.002) and aerosol mask (4.6±0.4%; p=0.002), and the dragon mask was more efficient than the open aerosol mask (p=0.009) CONCLUSION: The type of nebulizer and interface used for aerosol therapy affects delivery efficiency in these simulated spontaneously breathing adult and pediatric models. Drug delivery was greatest with the valved-mouthpiece and mask with JN and MN, while the standard aerosol mask was least efficient in these simulated spontaneously breathing adult and pediatric lung models. Delivery efficiency of JN was less than MN in all conditions tested in this study except in the aerosol mask. Lung deposition obtained with the adult lung model was more than that with the pediatric lung model.

  15. Binaural Hearing Ability With Bilateral Bone Conduction Stimulation in Subjects With Normal Hearing: Implications for Bone Conduction Hearing Aids.

    PubMed

    Zeitooni, Mehrnaz; Mäki-Torkko, Elina; Stenfelt, Stefan

    The purpose of this study is to evaluate binaural hearing ability in adults with normal hearing when bone conduction (BC) stimulation is bilaterally applied at the bone conduction hearing aid (BCHA) implant position as well as at the audiometric position on the mastoid. The results with BC stimulation are compared with bilateral air conduction (AC) stimulation through earphones. Binaural hearing ability is investigated with tests of spatial release from masking and binaural intelligibility level difference using sentence material, binaural masking level difference with tonal chirp stimulation, and precedence effect using noise stimulus. In all tests, results with bilateral BC stimulation at the BCHA position illustrate an ability to extract binaural cues similar to BC stimulation at the mastoid position. The binaural benefit is overall greater with AC stimulation than BC stimulation at both positions. The binaural benefit for BC stimulation at the mastoid and BCHA position is approximately half in terms of decibels compared with AC stimulation in the speech based tests (spatial release from masking and binaural intelligibility level difference). For binaural masking level difference, the binaural benefit for the two BC positions with chirp signal phase inversion is approximately twice the benefit with inverted phase of the noise. The precedence effect results with BC stimulation at the mastoid and BCHA position are similar for low frequency noise stimulation but differ with high-frequency noise stimulation. The results confirm that binaural hearing processing with bilateral BC stimulation at the mastoid position is also present at the BCHA implant position. This indicates the ability for binaural hearing in patients with good cochlear function when using bilateral BCHAs.

  16. Variations in backward masking with different masking stimuli: II. The effects of spatially quantised masks in the light of local contour interaction, interchannel inhibition, perceptual retouch, and substitution theories.

    PubMed

    Bachmann, Talis; Luiga, Iiris; Põder, Endel

    2005-01-01

    In part I we showed that with spatially non-overlapping targets and masks both local metacontrast-like interactions and attentional processes are involved in backward masking. In this second part we extend the strategy of varying the contents of masks to pattern masking where targets and masks overlap in space, in order to compare different masking theories. Images of human faces were backward-masked by three types of spatially quantised masks (the same faces as targets, faces different from targets, and Gaussian noise with power spectra typical for faces). Configural characteristics, rather than the spectral content of the mask, predicted the extent of masking at relatively long stimulus onset asynchronies (SOAs). This poses difficulties for the theory of transient-on-sustained inhibition as the principal mechanism of masking and also for local contour interaction being a decisive factor in pattern masking. The scale of quantisation had no effect on the masking capacity of noise masks and a strong effect on the capacity of different-face masks. Also, the decrease of configural masking with an increase in the coarseness of the quantisation of the mask highlights ambiguities inherent in the re-entrance-based substitution theory of masking. Different masking theories cannot solve the problems of masking separately. They should be combined in order to create a complex, yet comprehensible mode of interaction for the different mechanisms involved in visual backward masking.

  17. Do different perceptual task sets modulate electrophysiological correlates of masked visuomotor priming? Attention to shape and color put to the test.

    PubMed

    Zovko, Monika; Kiefer, Markus

    2013-02-01

    According to classical theories, automatic processes operate independently of attention. Recent evidence, however, shows that masked visuomotor priming, an example of an automatic process, depends on attention to visual form versus semantics. In a continuation of this approach, we probed feature-specific attention within the perceptual domain and tested in two event-related potential (ERP) studies whether masked visuomotor priming in a shape decision task specifically depends on attentional sensitization of visual pathways for shape in contrast to color. Prior to the masked priming procedure, a shape or a color decision task served to induce corresponding task sets. ERP analyses revealed visuomotor priming effects over the occipitoparietal scalp only after the shape, but not after the color induction task. Thus, top-down control coordinates automatic processing streams in congruency with higher-level goals even at a fine-grained level. Copyright © 2012 Society for Psychophysiological Research.

  18. Forward Masking in Cochlear Implant Users: Electrophysiological and Psychophysical Data Using Pulse Train Maskers.

    PubMed

    Adel, Youssef; Hilkhuysen, Gaston; Noreña, Arnaud; Cazals, Yves; Roman, Stéphane; Macherey, Olivier

    2017-06-01

    Electrical stimulation of auditory nerve fibers using cochlear implants (CI) shows psychophysical forward masking (pFM) up to several hundreds of milliseconds. By contrast, recovery of electrically evoked compound action potentials (eCAPs) from forward masking (eFM) was shown to be more rapid, with time constants no greater than a few milliseconds. These discrepancies suggested two main contributors to pFM: a rapid-recovery process due to refractory properties of the auditory nerve and a slow-recovery process arising from more central structures. In the present study, we investigate whether the use of different maskers between eCAP and psychophysical measures, specifically single-pulse versus pulse train maskers, may have been a source of confound.In experiment 1, we measured eFM using the following: a single-pulse masker, a 300-ms low-rate pulse train masker (LTM, 250 pps), and a 300-ms high-rate pulse train masker (HTM, 5000 pps). The maskers were presented either at same physical current (Φ) or at same perceptual (Ψ) level corresponding to comfortable loudness. Responses to a single-pulse probe were measured for masker-probe intervals ranging from 1 to 512 ms. Recovery from masking was much slower for pulse trains than for the single-pulse masker. When presented at Φ level, HTM produced more and longer-lasting masking than LTM. However, results were inconsistent when LTM and HTM were compared at Ψ level. In experiment 2, masked detection thresholds of single-pulse probes were measured using the same pulse train masker conditions. In line with our eFM findings, masked thresholds for HTM were higher than those for LTM at Φ level. However, the opposite result was found when the pulse trains were presented at Ψ level.Our results confirm the presence of slow-recovery phenomena at the level of the auditory nerve in CI users, as previously shown in animal studies. Inconsistencies between eFM and pFM results, despite using the same masking conditions, further underline the importance of comparing electrophysiological and psychophysical measures with identical stimulation paradigms.

  19. Challenges in evaluating PM concentration levels, commuting exposure, and mask efficacy in reducing PM exposure in growing, urban communities in a developing country.

    PubMed

    Patel, Disa; Shibata, Tomoyuki; Wilson, James; Maidin, Alimin

    2016-02-01

    Particulate matter (PM) contributes to an increased risk of respiratory and cardiovascular illnesses, cancer, and preterm birth complications. This project assessed PM exposure in Eastern Indonesia's largest city, where air quality has not been comprehensively monitored. We examined the efficacy of wearing masks as an individual intervention effort to reduce in-transit PM exposures. Handheld particulate counters were used to investigate ambient air quality for spatial analysis, as well as the differences in exposure to PM2.5 and PM10 (μg/m(3)) by different transportation methods [e.g. motorcycle (n=97), pete-pete (n=53), and car (n=55); note: n=1 means 1m(3) of air sample]. Mask efficacy to reduce PM exposure was evaluated [e.g. surgical masks (n=39), bandanas (n=52), and motorcycle masks (n=39)]. A Monte Carlo simulation was used to provide a range of uncertainty in exposure assessment. Overall PM10 levels (91±124 μg/m(3)) were elevated compared to the World Health Organization (WHO)'s 24-hour air quality guideline (50 μg/m(3)). While average PM2.5 levels (9±14 μg/m(3)) were below the WHO's guideline (25 μg/m(3)), measurements up to 139 μg/m(3) were observed. Compared to cars, average motorcycle and pete-pete PM exposures were four and three times higher for PM2.5, and 13 and 10 times higher for PM10, respectively. Only surgical masks were consistent in lowering PM2.5 and PM10 (p<0.01). Young children (≤5) were the most vulnerable age group, and could not reach the safe dosage even when wearing surgical masks. Individual interventions can effectively reduce individual PM exposures; however, policy interventions will be needed to improve the overall air quality and create safer transportation. Copyright © 2015 Elsevier B.V. All rights reserved.

  20. Hearing speech in music.

    PubMed

    Ekström, Seth-Reino; Borg, Erik

    2011-01-01

    The masking effect of a piano composition, played at different speeds and in different octaves, on speech-perception thresholds was investigated in 15 normal-hearing and 14 moderately-hearing-impaired subjects. Running speech (just follow conversation, JFC) testing and use of hearing aids increased the everyday validity of the findings. A comparison was made with standard audiometric noises [International Collegium of Rehabilitative Audiology (ICRA) noise and speech spectrum-filtered noise (SPN)]. All masking sounds, music or noise, were presented at the same equivalent sound level (50 dBA). The results showed a significant effect of piano performance speed and octave (P<.01). Low octave and fast tempo had the largest effect; and high octave and slow tempo, the smallest. Music had a lower masking effect than did ICRA noise with two or six speakers at normal vocal effort (P<.01) and SPN (P<.05). Subjects with hearing loss had higher masked thresholds than the normal-hearing subjects (P<.01), but there were smaller differences between masking conditions (P<.01). It is pointed out that music offers an interesting opportunity for studying masking under realistic conditions, where spectral and temporal features can be varied independently. The results have implications for composing music with vocal parts, designing acoustic environments and creating a balance between speech perception and privacy in social settings.

  1. Modeling OPC complexity for design for manufacturability

    NASA Astrophysics Data System (ADS)

    Gupta, Puneet; Kahng, Andrew B.; Muddu, Swamy; Nakagawa, Sam; Park, Chul-Hong

    2005-11-01

    Increasing design complexity in sub-90nm designs results in increased mask complexity and cost. Resolution enhancement techniques (RET) such as assist feature addition, phase shifting (attenuated PSM) and aggressive optical proximity correction (OPC) help in preserving feature fidelity in silicon but increase mask complexity and cost. Data volume increase with rise in mask complexity is becoming prohibitive for manufacturing. Mask cost is determined by mask write time and mask inspection time, which are directly related to the complexity of features printed on the mask. Aggressive RET increase complexity by adding assist features and by modifying existing features. Passing design intent to OPC has been identified as a solution for reducing mask complexity and cost in several recent works. The goal of design-aware OPC is to relax OPC tolerances of layout features to minimize mask cost, without sacrificing parametric yield. To convey optimal OPC tolerances for manufacturing, design optimization should drive OPC tolerance optimization using models of mask cost for devices and wires. Design optimization should be aware of impact of OPC correction levels on mask cost and performance of the design. This work introduces mask cost characterization (MCC) that quantifies OPC complexity, measured in terms of fracture count of the mask, for different OPC tolerances. MCC with different OPC tolerances is a critical step in linking design and manufacturing. In this paper, we present a MCC methodology that provides models of fracture count of standard cells and wire patterns for use in design optimization. MCC cannot be performed by designers as they do not have access to foundry OPC recipes and RET tools. To build a fracture count model, we perform OPC and fracturing on a limited set of standard cells and wire configurations with all tolerance combinations. Separately, we identify the characteristics of the layout that impact fracture count. Based on the fracture count (FC) data from OPC and mask data preparation runs, we build models of FC as function of OPC tolerances and layout parameters.

  2. Pressure Ulcer Incidence in Patients Wearing Nasal-Oral Versus Full-Face Noninvasive Ventilation Masks.

    PubMed

    Schallom, Marilyn; Cracchiolo, Lisa; Falker, Antoinette; Foster, Jennifer; Hager, JoAnn; Morehouse, Tamara; Watts, Peggy; Weems, Linda; Kollef, Marin

    2015-07-01

    Device-related pressure ulcers from noninvasive ventilation masks alter skin integrity and cause patients discomfort. To examine the incidence, location, and stage of pressure ulcers and patients' comfort with a nasal-oral mask compared with a full-face mask. A before-after study of a convenience sample of patients with noninvasive ventilation orders in 5 intensive care units was conducted. Two groups of 100 patients each received either the nasal-oral mask or the full-face mask. Skin was assessed before the mask was applied and every 12 hours after that or upon mask removal. Comfort levels were assessed every 12 hours on a Likert scale of 1 to 5 (1, most comfortable). A pressure ulcer developed in 20% of patients in the nasal-oral mask group and 2% of patients in the full-face mask group (P < .001). Comfort scores were significantly lower (more comfortable) with the full-face mask (mean [SD], 1.9 [1.1]) than with the nasal-oral mask (mean [SD], 2.7 [1.2], P < .001). Neither mean hours worn nor percentage adherence differed significantly: 28.9 (SD, 27.2) hours and 92% for full-face mask and 25 (SD, 20.7) and 92% for nasal-oral mask. No patients who had a pressure ulcer develop with the nasal-oral mask had a pressure ulcer develop with the full-face mask. The full-face mask resulted in significantly fewer pressure ulcers and was more comfortable for patients. The full-face mask is a reasonable alternative to traditional nasal-oral masks for patients receiving noninvasive ventilation. ©2015 American Association of Critical-Care Nurses.

  3. Exploring the additivity of binaural and monaural masking release

    PubMed Central

    Hall, Joseph W.; Buss, Emily; Grose, John H.

    2011-01-01

    Experiment 1 examined comodulation masking release (CMR) for a 700-Hz tonal signal under conditions of NoSo (noise and signal interaurally in phase) and NoSπ (noise in phase, signal out of phase) stimulation. The baseline stimulus for CMR was either a single 24-Hz wide narrowband noise centered on the signal frequency [on-signal band (OSB)] or the OSB plus, a set of flanking noise bands having random envelopes. Masking noise was either gated or continuous. The CMR, defined with respect to either the OSB or the random noise baseline, was smaller for NoSπ than NoSo stimulation, particularly when the masker was continuous. Experiment 2 examined whether the same pattern of results would be obtained for a 2000-Hz signal frequency; the number of flanking bands was also manipulated (two versus eight). Results again showed smaller CMR for NoSπ than NoSo stimulation for both continuous and gated masking noise. The CMR was larger with eight than with two flanking bands, and this difference was greater for NoSo than NoSπ. The results of this study are compatible with serial mechanisms of binaural and monaural masking release, but they indicate that the combined masking release (binaural masking-level difference and CMR) falls short of being additive. PMID:21476663

  4. Alternating phase-shifted mask for logic gate levels, design, and mask manufacturing

    NASA Astrophysics Data System (ADS)

    Liebmann, Lars W.; Graur, Ioana C.; Leipold, William C.; Oberschmidt, James M.; O'Grady, David S.; Regaill, Denis

    1999-07-01

    While the benefits of alternating phase shifted masks in improving lithographic process windows at increased resolution are well known throughout the lithography community, broad implementation of this potentially powerful technique has been slow due to the inherent complexity of the layout design and mask manufacturing process. This paper will review a project undertaken at IBM's Semiconductor Research and Development Center and Mask Manufacturing and Development facility to understand the technical and logistical issues associated with the application of alternating phase shifted mask technology to the gate level of a full microprocessor chip. The work presented here depicts an important milestone toward integration of alternating phase shifted masks into the manufacturing process by demonstrating an automated design solution and yielding a functional alternating phase shifted mask. The design conversion of the microprocessor gate level to a conjugate twin shifter alternating phase shift layout was accomplished with IBM's internal design system that automatically scaled the design, added required phase regions, and resolved phase conflicts. The subsequent fabrication of a nearly defect free phase shifted mask, as verified by SEM based die to die inspection, highlights the maturity of the alternating phase shifted mask manufacturing process in IBM's internal mask facility. Well defined and recognized challenges in mask inspection and repair remain and the layout of alternating phase shifted masks present a design and data preparation overhead, but the data presented here demonstrate the feasibility of designing and building manufacturing quality alternating phase shifted masks for the gate level of a microprocessor.

  5. Individual differences in metacontrast masking regarding sensitivity and response bias.

    PubMed

    Albrecht, Thorsten; Mattler, Uwe

    2012-09-01

    In metacontrast masking target visibility is modulated by the time until a masking stimulus appears. The effect of this temporal delay differs across participants in such a way that individual human observers' performance shows distinguishable types of masking functions which remain largely unchanged for months. Here we examined whether individual differences in masking functions depend on different response criteria in addition to differences in discrimination sensitivity. To this end we reanalyzed previously published data and conducted a new experiment for further data analyses. Our analyses demonstrate that a distinction of masking functions based on the type of masking stimulus is superior to a distinction based on the target-mask congruency. Individually different masking functions are based on individual differences in discrimination sensitivities and in response criteria. Results suggest that individual differences in metacontrast masking result from individually different criterion contents. Copyright © 2012 Elsevier Inc. All rights reserved.

  6. Functional neuroanatomy of visual masking deficits in schizophrenia.

    PubMed

    Green, Michael F; Lee, Junghee; Cohen, Mark S; Engel, Steven A; Korb, Alexander S; Nuechterlein, Keith H; Wynn, Jonathan K; Glahn, David C

    2009-12-01

    Visual masking procedures assess the earliest stages of visual processing. Patients with schizophrenia reliably show deficits on visual masking, and these procedures have been used to explore vulnerability to schizophrenia, probe underlying neural circuits, and help explain functional outcome. To identify and compare regional brain activity associated with one form of visual masking (ie, backward masking) in schizophrenic patients and healthy controls. Subjects received functional magnetic resonance imaging scans. While in the scanner, subjects performed a backward masking task and were given 3 functional localizer activation scans to identify early visual processing regions of interest (ROIs). University of California, Los Angeles, and the Department of Veterans Affairs Greater Los Angeles Healthcare System. Nineteen patients with schizophrenia and 19 healthy control subjects. Main Outcome Measure The magnitude of the functional magnetic resonance imaging signal during backward masking. Two ROIs (lateral occipital complex [LO] and the human motion selective cortex [hMT+]) showed sensitivity to the effects of masking, meaning that signal in these areas increased as the target became more visible. Patients had lower activation than controls in LO across all levels of visibility but did not differ in other visual processing ROIs. Using whole-brain analyses, we also identified areas outside the ROIs that were sensitive to masking effects (including bilateral inferior parietal lobe and thalamus), but groups did not differ in signal magnitude in these areas. The study results support a key role in LO for visual masking, consistent with previous studies in healthy controls. The current results indicate that patients fail to activate LO to the same extent as controls during visual processing regardless of stimulus visibility, suggesting a neural basis for the visual masking deficit, and possibly other visual integration deficits, in schizophrenia.

  7. Availability, consistency and evidence-base of policies and guidelines on the use of mask and respirator to protect hospital health care workers: a global analysis

    PubMed Central

    2013-01-01

    Background Currently there is an ongoing debate and limited evidence on the use of masks and respirators for the prevention of respiratory infections in health care workers (HCWs). This study aimed to examine available policies and guidelines around the use of masks and respirators in HCWs and to describe areas of consistency between guidelines, as well as gaps in the recommendations, with reference to the WHO and the CDC guidelines. Methods Policies and guidelines related to mask and respirator use for the prevention of influenza, SARS and TB were examined. Guidelines from the World Health Organization (WHO), the Center for Disease Control and Prevention (CDC), three high-income countries and six low/middle-income countries were selected. Results Uniform recommendations are made by the WHO and the CDC in regards to protecting HCWs against seasonal influenza (a mask for low risk situations and a respirator for high risk situations) and TB (use of a respirator). However, for pandemic influenza and SARS, the WHO recommends mask use in low risk and respirators in high risk situations, whereas, the CDC recommends respirators in both low and high risk situations. Amongst the nine countries reviewed, there are variations in the recommendations for all three diseases. While, some countries align with the WHO recommendations, others align with those made by the CDC. The choice of respirator and the level of filtering ability vary amongst the guidelines and the different diseases. Lastly, none of the policies discuss reuse, extended use or the use of cloth masks. Conclusion Currently, there are significant variations in the policies and recommendations around mask and respirator use for protection against influenza, SARS and TB. These differences may reflect the scarcity of level-one evidence available to inform policy development. The lack of any guidelines on the use of cloth masks, despite widespread use in many low and middle-income countries, remains a policy gap. Health organizations and countries should jointly evaluate the available evidence, prioritize research to inform evidence gaps, and develop consistent policy on masks and respirator use in the health care setting. PMID:23725338

  8. Availability, consistency and evidence-base of policies and guidelines on the use of mask and respirator to protect hospital health care workers: a global analysis.

    PubMed

    Chughtai, Abrar Ahmad; Seale, Holly; MacIntyre, Chandini Raina

    2013-05-31

    Currently there is an ongoing debate and limited evidence on the use of masks and respirators for the prevention of respiratory infections in health care workers (HCWs). This study aimed to examine available policies and guidelines around the use of masks and respirators in HCWs and to describe areas of consistency between guidelines, as well as gaps in the recommendations, with reference to the WHO and the CDC guidelines. Policies and guidelines related to mask and respirator use for the prevention of influenza, SARS and TB were examined. Guidelines from the World Health Organization (WHO), the Center for Disease Control and Prevention (CDC), three high-income countries and six low/middle-income countries were selected. Uniform recommendations are made by the WHO and the CDC in regards to protecting HCWs against seasonal influenza (a mask for low risk situations and a respirator for high risk situations) and TB (use of a respirator). However, for pandemic influenza and SARS, the WHO recommends mask use in low risk and respirators in high risk situations, whereas, the CDC recommends respirators in both low and high risk situations. Amongst the nine countries reviewed, there are variations in the recommendations for all three diseases. While, some countries align with the WHO recommendations, others align with those made by the CDC. The choice of respirator and the level of filtering ability vary amongst the guidelines and the different diseases. Lastly, none of the policies discuss reuse, extended use or the use of cloth masks. Currently, there are significant variations in the policies and recommendations around mask and respirator use for protection against influenza, SARS and TB. These differences may reflect the scarcity of level-one evidence available to inform policy development. The lack of any guidelines on the use of cloth masks, despite widespread use in many low and middle-income countries, remains a policy gap. Health organizations and countries should jointly evaluate the available evidence, prioritize research to inform evidence gaps, and develop consistent policy on masks and respirator use in the health care setting.

  9. Full-chip level MEEF analysis using model based lithography verification

    NASA Astrophysics Data System (ADS)

    Kim, Juhwan; Wang, Lantian; Zhang, Daniel; Tang, Zongwu

    2005-11-01

    MEEF (Mask Error Enhancement Factor) has become a critical factor in CD uniformity control since optical lithography process moved to sub-resolution era. A lot of studies have been done by quantifying the impact of the mask CD (Critical Dimension) errors on the wafer CD errors1-2. However, the benefits from those studies were restricted only to small pattern areas of the full-chip data due to long simulation time. As fast turn around time can be achieved for the complicated verifications on very large data by linearly scalable distributed processing technology, model-based lithography verification becomes feasible for various types of applications such as post mask synthesis data sign off for mask tape out in production and lithography process development with full-chip data3,4,5. In this study, we introduced two useful methodologies for the full-chip level verification of mask error impact on wafer lithography patterning process. One methodology is to check MEEF distribution in addition to CD distribution through process window, which can be used for RET/OPC optimization at R&D stage. The other is to check mask error sensitivity on potential pinch and bridge hotspots through lithography process variation, where the outputs can be passed on to Mask CD metrology to add CD measurements on those hotspot locations. Two different OPC data were compared using the two methodologies in this study.

  10. Masked polycythaemia vera: presenting features, response to treatment and clinical outcomes.

    PubMed

    Alvarez-Larrán, Alberto; Angona, Anna; Ancochea, Agueda; García-Pallarols, Francesc; Fernández, Concepción; Longarón, Raquel; Bellosillo, Beatriz; Besses, Carlos

    2016-01-01

    Masked polycythaemia vera (PV) has been proposed as a new entity with poorer outcome than overt PV. In this study, the initial clinical and laboratory characteristics, response to treatment and outcome of masked and overt PV were compared using red cell mass and haemoglobin or haematocrit levels for the distinction between both entities. Sixty-eight of 151 PV patients (45%) were classified as masked PV according to World Health Organisation diagnostic criteria, whereas 16 (11%) were classified as masked PV using the British Committee for Standards in Haematology (BCSH). In comparison with overt PV, a higher platelet count and a lower JAK2V617F allele burden at diagnosis were observed in masked PV. Patients with masked PV needed lower phlebotomies and responded faster to hydroxcarbamide than those with overt PV. Complete haematological response was more frequently achieved in masked than in overt PV (79% vs. 58%, P = 0.001). There were no significant differences in the duration of haematological response, the rate of resistance or intolerance to hydroxycarbamide and the probability of molecular response according to type of PV (masked vs. overt). Overall survival, rate of thrombosis and major bleeding, and probability of transformation was superimposable among patients with masked and overt PV. © 2015 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  11. A survey of practice patterns in the use of laryngeal mask by pediatric anesthesiologists.

    PubMed

    Patel, Anuradha; Clark, Scott R; Schiffmiller, Moshe; Schoenberg, Catherine; Tewfik, George

    2015-11-01

    Laryngeal mask is frequently the airway device of choice in routine general anesthesia for many procedures in children. Several studies have described the use of laryngeal masks in unconventional situations. This survey was undertaken to assess how laryngeal masks are being used by pediatric anesthesiologists. The 40-question electronic survey using SurveyMonkey™ was sent to 2740 members of the Society for Pediatric Anesthesia (SPA). This survey assessed the age, work environment, types of practice, and training levels, as well as clinical situations in which the practitioners use laryngeal masks across different pediatric age groups. Seven hundred and forty-three (27.1%) responses were obtained. The use of laryngeal mask increased as the patient age increased in nearly every queried situation. The practitioners routinely utilize laryngeal masks in a variety of challenging scenarios, such as in patients with a recent upper respiratory infection, in the difficult airway, remote locations, and long-duration surgeries. A small percentage of pediatric anesthesiologists use laryngeal masks in laparoscopic surgery and prone position procedures. Pediatric anesthesiologists are using laryngeal masks in both routine and challenging/unconventional situations. Although many of the uses for laryngeal masks are not explicitly stated in the manufacturer guidelines, literature and current practice support the use of laryngeal masks in several of these scenarios. © 2015 John Wiley & Sons Ltd.

  12. Psychophysical "blinding" methods reveal a functional hierarchy of unconscious visual processing.

    PubMed

    Breitmeyer, Bruno G

    2015-09-01

    Numerous non-invasive experimental "blinding" methods exist for suppressing the phenomenal awareness of visual stimuli. Not all of these suppressive methods occur at, and thus index, the same level of unconscious visual processing. This suggests that a functional hierarchy of unconscious visual processing can in principle be established. The empirical results of extant studies that have used a number of different methods and additional reasonable theoretical considerations suggest the following tentative hierarchy. At the highest levels in this hierarchy is unconscious processing indexed by object-substitution masking. The functional levels indexed by crowding, the attentional blink (and other attentional blinding methods), backward pattern masking, metacontrast masking, continuous flash suppression, sandwich masking, and single-flash interocular suppression, fall at progressively lower levels, while unconscious processing at the lowest levels is indexed by eye-based binocular-rivalry suppression. Although unconscious processing levels indexed by additional blinding methods is yet to be determined, a tentative placement at lower levels in the hierarchy is also given for unconscious processing indexed by Troxler fading and adaptation-induced blindness, and at higher levels in the hierarchy indexed by attentional blinding effects in addition to the level indexed by the attentional blink. The full mapping of levels in the functional hierarchy onto cortical activation sites and levels is yet to be determined. The existence of such a hierarchy bears importantly on the search for, and the distinctions between, neural correlates of conscious and unconscious vision. Copyright © 2015 Elsevier Inc. All rights reserved.

  13. On the impact of masking and blocking hypotheses for measuring the efficacy of new tuberculosis vaccines.

    PubMed

    Arregui, Sergio; Sanz, Joaquín; Marinova, Dessislava; Martín, Carlos; Moreno, Yamir

    2016-01-01

    Over the past 60 years, the Mycobacterium bovis bacille Calmette-Guérin (BCG) has been used worldwide to prevent tuberculosis (TB). However, BCG has shown a very variable efficacy in different trials, offering a wide range of protection in adults against pulmonary TB. One of the most accepted hypotheses to explain these inconsistencies points to the existence of a pre-existing immune response to antigens that are common to environmental sources of mycobacterial antigens and Mycobacterium tuberculosis. Specifically, two different mechanisms have been hypothesized to explain this phenomenon: the masking and the blocking effects. According to masking hypothesis, previous sensitization confers some level of protection against TB that masks vaccine's effects. In turn, the blocking hypothesis postulates that previous immune response prevents vaccine taking of a new TB vaccine. In this work we introduce a series of models to discriminate between masking and blocking mechanisms and address their relative likelihood. We apply our methodology to the data reported by BCG-REVAC clinical trials, which were specifically designed for studying BCG efficacy variability. Our results yield estimates that are consistent with high levels of blocking (41% in Manaus -95% CI [14-68]- and 96% in Salvador -95% CI [52-100]-). Moreover, we also show that masking does not play any relevant role in modifying vaccine's efficacy either alone or in addition to blocking. The quantification of these effects around a plausible model constitutes a relevant step towards impact evaluation of novel anti-tuberculosis vaccines, which are susceptible of being affected by similar effects, especially if applied on individuals previously exposed to mycobacterial antigens.

  14. What's behind the mask? A look at blood flow changes with prolonged facial pressure and expression using laser Doppler imaging.

    PubMed

    Van-Buendia, Lan B; Allely, Rebekah R; Lassiter, Ronald; Weinand, Christian; Jordan, Marion H; Jeng, James C

    2010-01-01

    Clinically, the initial blanching in burn scar seen on transparent plastic face mask application seems to diminish with time and movement requiring mask alteration. To date, studies quantifying perfusion with prolonged mask use do not exist. This study used laser Doppler imaging (LDI) to assess perfusion through the transparent face mask and movement in subjects with and without burn over time. Five subjects fitted with transparent face masks were scanned with the LDI on four occasions. The four subjects without burn were scanned in the following manner: 1) no mask, 2) mask on while at rest, 3) mask on with alternating intervals of sustained facial expression and rest, and 4) after mask removal. Images were acquired every 3 minutes throughout the 85-minute study period. The subject with burn underwent a shortened scanning protocol to increase comfort. Each face was divided into five regions of interest for analysis. Compared with baseline, mask application decreased perfusion significantly in all subjects (P < .0001). Perfusion did not change during the rest period. There were no significant differences with changing facial expression in any of the regions of interest. On mask removal, all regions of the face demonstrated a hyperemic effect with the chin (P = .05) and each cheek (P < .0001) reaching statistical significance. Perfusion levels did not return to baseline in the chin and cheeks after 30 minutes of mask removal. Perfusions remain constantly low while wearing the face mask, despite changing facial expressions. Changing facial expressions with the mask on did not alter perfusion. Hyperemic response occurs on removal of the mask. This study exposed methodology and statistical issues worth considering when conducting future research with the face, pressure therapy, and with LDI technology.

  15. Coronagraphic mask design using Hermite functions.

    PubMed

    Cagigal, Manuel P; Canales, Vidal F; Valle, Pedro J; Oti, José E

    2009-10-26

    We introduce a stellar coronagraph that uses a coronagraphic mask described by a Hermite function or a combination of them. It allows the detection of exoplanets providing both deep starlight extinction and high angular resolution. This angular resolution depends on the order of the Hermite function used. An analysis of the coronagraph performance is carried out for different even order masks. Numerical simulations of the ideal case, with no phase errors and perfect telescope pointing, show that on-axis starlight is reduced to very low intensity levels corresponding to a gain of at least 25 magnitudes (10(-10) light intensity reduction). The coronagraphic throughput depends on the Hermite function or combination selected. The proposed mask series presents the same advantages of band limited masks along with the benefit of reducing the light diffracted by the mask border thanks to its particular shape. Nevertheless, for direct detection of Earth-like exoplanets it requires the use of adaptive optics facilities for compensating the perturbations introduced by the atmosphere and by the optical system.

  16. Exploring the additivity of binaural and monaural masking release.

    PubMed

    Hall, Joseph W; Buss, Emily; Grose, John H

    2011-04-01

    Experiment 1 examined comodulation masking release (CMR) for a 700-Hz tonal signal under conditions of N(o)S(o) (noise and signal interaurally in phase) and N(o)S(π) (noise in phase, signal out of phase) stimulation. The baseline stimulus for CMR was either a single 24-Hz wide narrowband noise centered on the signal frequency [on-signal band (OSB)] or the OSB plus, a set of flanking noise bands having random envelopes. Masking noise was either gated or continuous. The CMR, defined with respect to either the OSB or the random noise baseline, was smaller for N(o)S(π) than N(o)S(o) stimulation, particularly when the masker was continuous. Experiment 2 examined whether the same pattern of results would be obtained for a 2000-Hz signal frequency; the number of flanking bands was also manipulated (two versus eight). Results again showed smaller CMR for N(o)S(π) than N(o)S(o) stimulation for both continuous and gated masking noise. The CMR was larger with eight than with two flanking bands, and this difference was greater for N(o)S(o) than N(o)S(π). The results of this study are compatible with serial mechanisms of binaural and monaural masking release, but they indicate that the combined masking release (binaural masking-level difference and CMR) falls short of being additive.

  17. Procedural Factors That Affect Psychophysical Measures of Spatial Selectivity in Cochlear Implant Users

    PubMed Central

    Deeks, John M.; Carlyon, Robert P.

    2015-01-01

    Behavioral measures of spatial selectivity in cochlear implants are important both for guiding the programing of individual users’ implants and for the evaluation of different stimulation methods. However, the methods used are subject to a number of confounding factors that can contaminate estimates of spatial selectivity. These factors include off-site listening, charge interactions between masker and probe pulses in interleaved masking paradigms, and confusion effects in forward masking. We review the effects of these confounds and discuss methods for minimizing them. We describe one such method in which the level of a 125-pps masker is adjusted so as to mask a 125-pps probe, and where the masker and probe pulses are temporally interleaved. Five experiments describe the method and evaluate the potential roles of the different potential confounding factors. No evidence was obtained for off-site listening of the type observed in acoustic hearing. The choice of the masking paradigm was shown to alter the measured spatial selectivity. For short gaps between masker and probe pulses, both facilitation and refractory mechanisms had an effect on masking; this finding should inform the choice of stimulation rate in interleaved masking experiments. No evidence for confusion effects in forward masking was revealed. It is concluded that the proposed method avoids many potential confounds but that the choice of method should depend on the research question under investigation. PMID:26420785

  18. Hearing Sensitivity to Shifts of Rippled-Spectrum Sound Signals in Masking Noise.

    PubMed

    Nechaev, Dmitry I; Milekhina, Olga N; Supin, Alexander Ya

    2015-01-01

    The goal of the study was to enlarge knowledge of discrimination of complex sound signals by the auditory system in masking noise. For that, influence of masking noise on detection of shift of rippled spectrum was studied in normal listeners. The signal was a shift of ripple phase within a 0.5-oct wide rippled spectrum centered at 2 kHz. The ripples were frequency-proportional (throughout the band, ripple spacing was a constant proportion of the ripple center frequency). Simultaneous masker was a 0.5-oct noise below-, on-, or above the signal band. Both the low-frequency (center frequency 1 kHz) and on-frequency (the same center frequency as for the signal) maskers increased the thresholds for detecting ripple phase shift. However, the threshold dependence on the masker level was different for these two maskers. For the on-frequency masker, the masking effect primarily depended on the masker/signal ratio: the threshold steeply increased at a ratio of 5 dB, and no shift was detectable at a ratio of 10 dB. For the low-frequency masker, the masking effect primarily depended on the masker level: the threshold increased at a masker level of 80 dB SPL, and no shift was detectable at a masker level of 90 dB (for a signal level of 50 dB) or 100 dB (for a signal level of 80 dB). The high-frequency masker had little effect. The data were successfully simulated using an excitation-pattern model. In this model, the effect of the on-frequency masker appeared to be primarily due to a decrease of ripple depth. The effect of the low-frequency masker appeared due to widening of the auditory filters at high sound levels.

  19. Hearing Sensitivity to Shifts of Rippled-Spectrum Sound Signals in Masking Noise

    PubMed Central

    Nechaev, Dmitry I.; Milekhina, Olga N.; Supin, Alexander Ya.

    2015-01-01

    The goal of the study was to enlarge knowledge of discrimination of complex sound signals by the auditory system in masking noise. For that, influence of masking noise on detection of shift of rippled spectrum was studied in normal listeners. The signal was a shift of ripple phase within a 0.5-oct wide rippled spectrum centered at 2 kHz. The ripples were frequency-proportional (throughout the band, ripple spacing was a constant proportion of the ripple center frequency). Simultaneous masker was a 0.5-oct noise below-, on-, or above the signal band. Both the low-frequency (center frequency 1 kHz) and on-frequency (the same center frequency as for the signal) maskers increased the thresholds for detecting ripple phase shift. However, the threshold dependence on the masker level was different for these two maskers. For the on-frequency masker, the masking effect primarily depended on the masker/signal ratio: the threshold steeply increased at a ratio of 5 dB, and no shift was detectable at a ratio of 10 dB. For the low-frequency masker, the masking effect primarily depended on the masker level: the threshold increased at a masker level of 80 dB SPL, and no shift was detectable at a masker level of 90 dB (for a signal level of 50 dB) or 100 dB (for a signal level of 80 dB). The high-frequency masker had little effect. The data were successfully simulated using an excitation-pattern model. In this model, the effect of the on-frequency masker appeared to be primarily due to a decrease of ripple depth. The effect of the low-frequency masker appeared due to widening of the auditory filters at high sound levels. PMID:26462066

  20. Informational Masking Effects on Neural Encoding of Stimulus Onset and Acoustic Change.

    PubMed

    Niemczak, Christopher E; Vander Werff, Kathy R

    2018-05-18

    Recent investigations using cortical auditory evoked potentials have shown masker-dependent effects on sensory cortical processing of speech information. Background noise maskers consisting of other people talking are particularly difficult for speech recognition. Behavioral studies have related this to perceptual masking, or informational masking, beyond just the overlap of the masker and target at the auditory periphery. The aim of the present study was to use cortical auditory evoked potentials, to examine how maskers (i.e., continuous speech-shaped noise [SSN] and multi-talker babble) affect the cortical sensory encoding of speech information at an obligatory level of processing. Specifically, cortical responses to vowel onset and formant change were recorded under different background noise conditions presumed to represent varying amounts of energetic or informational masking. The hypothesis was, that even at this obligatory cortical level of sensory processing, we would observe larger effects on the amplitude and latency of the onset and change components as the amount of informational masking increased across background noise conditions. Onset and change responses were recorded to a vowel change from /u-i/ in young adults under four conditions: quiet, continuous SSN, eight-talker (8T) babble, and two-talker (2T) babble. Repeated measures analyses by noise condition were conducted on amplitude, latency, and response area measurements to determine the differential effects of these noise conditions, designed to represent increasing and varying levels of informational and energetic masking, on cortical neural representation of a vowel onset and acoustic change response waveforms. All noise conditions significantly reduced onset N1 and P2 amplitudes, onset N1-P2 peak to peak amplitudes, as well as both onset and change response area compared with quiet conditions. Further, all amplitude and area measures were significantly reduced for the two babble conditions compared with continuous SSN. However, there were no significant differences in peak amplitude or area for either onset or change responses between the two different babble conditions (eight versus two talkers). Mean latencies for all onset peaks were delayed for noise conditions compared with quiet. However, in contrast to the amplitude and area results, differences in peak latency between SSN and the babble conditions did not reach statistical significance. These results support the idea that while background noise maskers generally reduce amplitude and increase latency of speech-sound evoked cortical responses, the type of masking has a significant influence. Speech babble maskers (eight talkers and two talkers) have a larger effect on the obligatory cortical response to speech sound onset and change compared with purely energetic continuous SSN maskers, which may be attributed to informational masking effects. Neither the neural responses to the onset nor the vowel change, however, were sensitive to the hypothesized increase in the amount of informational masking between speech babble maskers with two talkers compared with eight talkers.

  1. Anxiety sensitivity: the role of conscious awareness and selective attentional bias to physical threat.

    PubMed

    Hunt, Caroline; Keogh, Edmund; French, Christopher C

    2006-08-01

    Selective attentional biases were examined amongst individuals varying in levels of physical anxiety sensitivity. The dot-probe paradigm was used to examine attention towards anxiety symptomatology, social threat and positive words. Stimuli were presented above (unmasked) and below (masked) the level of conscious awareness. High physical anxiety sensitivity was associated with attentional vigilance for anxiety symptomatology words in both unmasked and masked conditions. For positive words, however, those high in anxiety sensitivity were found to avoid such stimuli when they were masked, whereas they exhibited a relative vigilance when unmasked. If the differences between awareness conditions are reliable, then the impact of the automatic vigilance for threat might be modified by conscious attempts to direct attention towards other types of stimuli. (c) 2006 APA, all rights reserved

  2. [Respiratory protection provided by N95 filtering facepiece respirators and disposable medicine masks against airborne bacteria in different working environments].

    PubMed

    Lu, W; Zhu, X C; Zhang, X Y; Chen, Y T; Chen, W H

    2016-09-20

    Objective: To determine the relative protection provided by N95 filtering facepiece respirators (FFR) and disposable medicine masks (DMM) against airborne bacteria in different working environments. Methods: The field study was performed with 12 subjects wearing an N95 filtering facepiece respirator and a disposable medicine mask for 1h, respectively. Airborne microorganisms and bacteria samples from both the external (Ce) and the inner (Ci) surface of N95 FFR and DMM are collected. The Ce: Ci ratio was used to calculate the bacterial filtering proportion. Bacterial filtering efficiency (BFE) was measured using the JWL-2A Sampler. Results: The bacterial filtration efficiency of N95 FFR and DMM were 99.93% and 91.53%, respectively. There was significant difference between the two materials ( P <0.05). In summer, airborne bacterial concentration was higher than that in winter. In the same season, airborne bacterial concentration in hospital environment is higher than that in campus. The higher the airborne bacterial concentration, the greater bacterial contaminated on the external surface of the used masks. To all masks used in different working environment, bacterial contamination on the external surface was much greater than the inner surface ( P <0.01). Compared to N95 FFR, DMM had slighter bacterial contamination on the external surface and greater bacterial contamination on the inner surface. However, this difference was not significant ( P >0.05). The bacterial filtering proportion of N95 FFR is higher than DMM. These differences were significant in samples tested in summer ( P <0.05) , but were not significant in samples tested in winter ( P >0.05). Conclusion: Bacterial filtering efficiency of N95 respirator is superior to medicine mask, and this advantage become more obvious in high airborne bacterial concentration levels.

  3. Speech recognition against harmonic and inharmonic complexes: Spectral dips and periodicity

    PubMed Central

    Deroche, Mickael L. D.; Culling, John F.; Chatterjee, Monita; Limb, Charles J.

    2014-01-01

    Speech recognition in a complex masker usually benefits from masker harmonicity, but there are several factors at work. The present study focused on two of them, glimpsing spectrally in between masker partials and periodicity within individual frequency channels. Using both a theoretical and an experimental approach, it is demonstrated that when inharmonic complexes are generated by jittering partials from their harmonic positions, there are better opportunities for spectral glimpsing in inharmonic than in harmonic maskers, and this difference is enhanced as fundamental frequency (F0) increases. As a result, measurements of masking level difference between the two maskers can be reduced, particularly at higher F0s. Using inharmonic maskers that offer similar glimpsing opportunity to harmonic maskers, it was found that the masking level difference between the two maskers varied little with F0, was influenced by periodicity of the first four partials, and could occur in low-, mid-, or high-frequency regions. Overall, the present results suggested that both spectral glimpsing and periodicity contribute to speech recognition under masking by harmonic complexes, and these effects seem independent from one another. PMID:24815268

  4. EUVL mask dual pods to be used for mask shipping and handling in exposure tools

    NASA Astrophysics Data System (ADS)

    Gomei, Yoshio; Ota, Kazuya; Lystad, John; Halbmair, Dave; He, Long

    2007-03-01

    The concept of Extreme Ultra-Violet Lithography (EUVL) mask dual pods is proposed for use in both mask shipping and handling in exposure tools. The inner pod was specially designed to protect masks from particle contamination during shipping from mask houses to wafer factories. It can be installed in a load-lock chamber of exposure tools and evacuated while holding the mask inside. The inner pod upper cover is removed just before the mask is installed to a mask stage. Prototypes were manufactured and tested for shipping and for vacuum cycling. We counted particle adders through these actions with a detectable level of 54 nm and up. The adder count was close to zero, or we can say that the obtained result is within the noise level of our present evaluation environment. This indicates that the present concept is highly feasible for EUVL mask shipping and handling in exposure tools.

  5. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Liu, Xiangkun; Pan, Chuzhong; Fan, Zuhui

    With numerical simulations, we analyze in detail how the bad data removal, i.e., the mask effect, can influence the peak statistics of the weak-lensing convergence field reconstructed from the shear measurement of background galaxies. It is found that high peak fractions are systematically enhanced because of the presence of masks; the larger the masked area is, the higher the enhancement is. In the case where the total masked area is about 13% of the survey area, the fraction of peaks with signal-to-noise ratio ν ≥ 3 is ∼11% of the total number of peaks, compared with ∼7% of the mask-freemore » case in our considered cosmological model. This can have significant effects on cosmological studies with weak-lensing convergence peak statistics, inducing a large bias in the parameter constraints if the effects are not taken into account properly. Even for a survey area of 9 deg{sup 2}, the bias in (Ω {sub m}, σ{sub 8}) is already intolerably large and close to 3σ. It is noted that most of the affected peaks are close to the masked regions. Therefore, excluding peaks in those regions in the peak statistics can reduce the bias effect but at the expense of losing usable survey areas. Further investigations find that the enhancement of the number of high peaks around the masked regions can be largely attributed to the smaller number of galaxies usable in the weak-lensing convergence reconstruction, leading to higher noise than that of the areas away from the masks. We thus develop a model in which we exclude only those very large masks with radius larger than 3' but keep all the other masked regions in peak counting statistics. For the remaining part, we treat the areas close to and away from the masked regions separately with different noise levels. It is shown that this two-noise-level model can account for the mask effect on peak statistics very well, and the bias in cosmological parameters is significantly reduced if this model is applied in the parameter fitting.« less

  6. Model of visual contrast gain control and pattern masking

    NASA Technical Reports Server (NTRS)

    Watson, A. B.; Solomon, J. A.

    1997-01-01

    We have implemented a model of contrast gain and control in human vision that incorporates a number of key features, including a contrast sensitivity function, multiple oriented bandpass channels, accelerating nonlinearities, and a devisive inhibitory gain control pool. The parameters of this model have been optimized through a fit to the recent data that describe masking of a Gabor function by cosine and Gabor masks [J. M. Foley, "Human luminance pattern mechanisms: masking experiments require a new model," J. Opt. Soc. Am. A 11, 1710 (1994)]. The model achieves a good fit to the data. We also demonstrate how the concept of recruitment may accommodate a variant of this model in which excitatory and inhibitory paths have a common accelerating nonlinearity, but which include multiple channels tuned to different levels of contrast.

  7. EUV phase-shifting masks and aberration monitors

    NASA Astrophysics Data System (ADS)

    Deng, Yunfei; Neureuther, Andrew R.

    2002-07-01

    Rigorous electromagnetic simulation with TEMPEST is used to examine the use of phase-shifting masks in EUV lithography. The effects of oblique incident illumination and mask patterning by ion-mixing of multilayers are analyzed. Oblique incident illumination causes streamers at absorber edges and causes position shifting in aerial images. The diffraction waves between ion-mixed and pristine multilayers are observed. The phase-shifting caused by stepped substrates is simulated and images show that it succeeds in creation of phase-shifting effects. The diffraction process at the phase boundary is also analyzed. As an example of EUV phase-shifting masks, a coma pattern and probe based aberration monitor is simulated and aerial images are formed under different levels of coma aberration. The probe signal rises quickly as coma increases as designed.

  8. Cycle time reduction by Html report in mask checking flow

    NASA Astrophysics Data System (ADS)

    Chen, Jian-Cheng; Lu, Min-Ying; Fang, Xiang; Shen, Ming-Feng; Ma, Shou-Yuan; Yang, Chuen-Huei; Tsai, Joe; Lee, Rachel; Deng, Erwin; Lin, Ling-Chieh; Liao, Hung-Yueh; Tsai, Jenny; Bowhill, Amanda; Vu, Hien; Russell, Gordon

    2017-07-01

    The Mask Data Correctness Check (MDCC) is a reticle-level, multi-layer DRC-like check evolved from mask rule check (MRC). The MDCC uses extended job deck (EJB) to achieve mask composition and to perform a detailed check for positioning and integrity of each component of the reticle. Different design patterns on the mask will be mapped to different layers. Therefore, users may be able to review the whole reticle and check the interactions between different designs before the final mask pattern file is available. However, many types of MDCC check results, such as errors from overlapping patterns usually have very large and complex-shaped highlighted areas covering the boundary of the design. Users have to load the result OASIS file and overlap it to the original database that was assembled in MDCC process on a layout viewer, then search for the details of the check results. We introduce a quick result-reviewing method based on an html format report generated by Calibre® RVE. In the report generation process, we analyze and extract the essential part of result OASIS file to a result database (RDB) file by standard verification rule format (SVRF) commands. Calibre® RVE automatically loads the assembled reticle pattern and generates screen shots of these check results. All the processes are automatically triggered just after the MDCC process finishes. Users just have to open the html report to get the information they need: for example, check summary, captured images of results and their coordinates.

  9. Place specificity of monopolar and tripolar stimuli in cochlear implants: the influence of residual masking.

    PubMed

    Fielden, Claire A; Kluk, Karolina; McKay, Colette M

    2013-06-01

    This experiment investigated whether place specificity of neural activity evoked by cochlear implant stimulation is improved in tripolar compared to monopolar mode using a forward masking protocol addressing some limitations of previous methods of measurement and analysis. The amount of residual masking (masking remaining at long masker-probe delays) was also measured, and its potential influence on the specificity measures was evaluated. The masker stimulus comprised equally loud interleaved mono- or tripolar stimulation on two electrodes equidistant from a central probe electrode in an apical and basal direction, reducing the influence of off-site listening. The effect of masker-probe distance on the threshold shift of the tripolar probe was analyzed to derive a measure of place specificity. On average, tripolar maskers were more place specific than monopolar maskers, although the mean effect was small. There was no significant effect of masker level on specificity or on the differences observed between modes. The mean influence of residual masking on normalized masking functions was similar for the two modes and, therefore, did not influence the comparison of specificity between the modes. However, variability in amount of residual masking was observed between subjects, and therefore should be considered in forward masking studies that compare place specificity across subjects.

  10. Perception of Water-Based Masking Sounds-Long-Term Experiment in an Open-Plan Office.

    PubMed

    Hongisto, Valtteri; Varjo, Johanna; Oliva, David; Haapakangas, Annu; Benway, Evan

    2017-01-01

    A certain level of masking sound is necessary to control the disturbance caused by speech sounds in open-plan offices. The sound is usually provided with evenly distributed loudspeakers. Pseudo-random noise is often used as a source of artificial sound masking (PRMS). A recent laboratory experiment suggested that water-based masking sound (WBMS) could be more favorable than PRMS. The purpose of our study was to determine how the employees perceived different WBMSs compared to PRMS. The experiment was conducted in an open-plan office of 77 employees who had been accustomed to work under PRMS (44 dB L Aeq ). The experiment consisted of five masking conditions: the original PRMS, four different WBMSs and return to the original PRMS. The exposure time of each condition was 3 weeks. The noise level was nearly equal between the conditions (43-45 dB L Aeq ) but the spectra and the nature of the sounds were very different. A questionnaire was completed at the end of each condition. Acoustic satisfaction was worse during the WBMSs than during the PRMS. The disturbance caused by three out of four WBMSs was larger than that of PRMS. Several attributes describing the sound quality itself were in favor of PRMS. Colleagues' speech sounds disturbed more during WBMSs. None of the WBMSs produced better subjective ratings than PRMS. Although the first WBMS was equal with the PRMS for several variables, the overall results cannot be seen to support the use of WBMSs in office workplaces. Because the experiment suffered from some methodological weaknesses, conclusions about the adequacy of WBMSs cannot yet be drawn.

  11. Perception of Water-Based Masking Sounds—Long-Term Experiment in an Open-Plan Office

    PubMed Central

    Hongisto, Valtteri; Varjo, Johanna; Oliva, David; Haapakangas, Annu; Benway, Evan

    2017-01-01

    A certain level of masking sound is necessary to control the disturbance caused by speech sounds in open-plan offices. The sound is usually provided with evenly distributed loudspeakers. Pseudo-random noise is often used as a source of artificial sound masking (PRMS). A recent laboratory experiment suggested that water-based masking sound (WBMS) could be more favorable than PRMS. The purpose of our study was to determine how the employees perceived different WBMSs compared to PRMS. The experiment was conducted in an open-plan office of 77 employees who had been accustomed to work under PRMS (44 dB LAeq). The experiment consisted of five masking conditions: the original PRMS, four different WBMSs and return to the original PRMS. The exposure time of each condition was 3 weeks. The noise level was nearly equal between the conditions (43–45 dB LAeq) but the spectra and the nature of the sounds were very different. A questionnaire was completed at the end of each condition. Acoustic satisfaction was worse during the WBMSs than during the PRMS. The disturbance caused by three out of four WBMSs was larger than that of PRMS. Several attributes describing the sound quality itself were in favor of PRMS. Colleagues' speech sounds disturbed more during WBMSs. None of the WBMSs produced better subjective ratings than PRMS. Although the first WBMS was equal with the PRMS for several variables, the overall results cannot be seen to support the use of WBMSs in office workplaces. Because the experiment suffered from some methodological weaknesses, conclusions about the adequacy of WBMSs cannot yet be drawn. PMID:28769834

  12. Single closed contact for 0.18-micron photolithography process

    NASA Astrophysics Data System (ADS)

    Cheung, Cristina; Phan, Khoi A.; Chiu, Robert J.

    2000-06-01

    With the rapid advances of deep submicron semiconductor technology, identifying defects is converted into a challenge for different modules in the fabrication of chips. Yield engineers often do bitmap on a memory circuit array (SRAM) to identify the failure bits. This is followed by a wafer stripback to look for visual defects at each deprocessed layer for feedback to the Fab. However, to identify the root cause of a problem, Fab engineers must be able to detect similar defects either on the product wafers in process or some short loop test wafers. In the photolithography process, we recognize that the detection of defects is becoming as important as satisfying the critical dimension (CD) of the device. For a multi-level metallization chemically mechanical polish backend process, it is very difficult to detect missing contacts or via at the masking steps due to metal grain roughness, film color variation and/or previous layer defects. Often, photolithography engineer must depend on Photo Cell Monitor (PCM) and short loop experiments for controlling baseline defects and improvement. In this paper, we discuss the findings on the Poly mask PCM and the Contact mask PCM. We present the comparison between the Poly mask and the Contact mask of the I-line Phase Shifted Via mask and DUV mask process for a 0.18 micron process technology. The correlation and the different type of defects between the Contact PCM and the Poly Mask are discussed. The Contact PCM was found to be more sensitive and correlated to contact failure at sort yield better. We also dedicate to study the root cause of a single closed contact hole in the Contact mask short loop experiment for a 0.18 micron process technology. A single closed contact defect was often caused by the developer process, such as bubbles in the line, resist residue left behind, and the rinse mechanism. We also found surfactant solution helps to improve the surface tension of the wafer for the developer process and this prevents/eliminates a single closed contact hole defects. The applications and effects of using different substrates like SiON, different thicknesses of Oxides, and Poly in the Contact Photo Mask is shown. Finally, some defect troubleshooting techniques and the root cause analysis are also discussed.

  13. Recovery from Object Substitution Masking Induced by Transient Suppression of Visual Motion Processing: A Repetitive Transcranial Magnetic Stimulation Study

    ERIC Educational Resources Information Center

    Hirose, Nobuyuki; Kihara, Ken; Mima, Tatsuya; Ueki, Yoshino; Fukuyama, Hidenao; Osaka, Naoyuki

    2007-01-01

    Object substitution masking is a form of visual backward masking in which a briefly presented target is rendered invisible by a lingering mask that is too sparse to produce lower image-level interference. Recent studies suggested the importance of an updating process in a higher object-level representation, which should rely on the processing of…

  14. Model based high NA anamorphic EUV RET

    NASA Astrophysics Data System (ADS)

    Jiang, Fan; Wiaux, Vincent; Fenger, Germain; Clifford, Chris; Liubich, Vlad; Hendrickx, Eric

    2018-03-01

    With the announcement of the extension of the Extreme Ultraviolet (EUV) roadmap to a high NA lithography tool that utilizes anamorphic optics design, an investigation of design tradeoffs unique to the imaging of anamorphic lithography tool is shown. An anamorphic optical proximity correction (OPC) solution has been developed that models fully the EUV near field electromagnetic effects and the anamorphic imaging using the Domain Decomposition Method (DDM). Clips of imec representative for the N3 logic node were used to demonstrate the OPC solutions on critical layers that will benefit from the increased contrast at high NA using anamorphic imaging. However, unlike isomorphic case, from wafer perspective, OPC needs to treat x and y differently. In the paper, we show a design trade-off seen unique to Anamorphic EUV, namely that using a mask rule of 48nm (mask scale), approaching current state of the art, limitations are observed in the available correction that can be applied to the mask. The metal pattern has a pitch of 24nm and CD of 12nm. During OPC, the correction of the metal lines oriented vertically are being limited by the mask rule of 12nm 1X. The horizontally oriented lines do not suffer from this mask rule limitation as the correction is allowed to go to 6nm 1X. For this example, the masks rules will need to be more aggressive to allow complete correction, or design rules and wafer processes (wafer rotation) would need to be created that utilize the orientation that can image more aggressive features. When considering VIA or block level correction, aggressive polygon corner to corner designs can be handled with various solutions, including applying a 45 degree chop. Multiple solutions are discussed with the metrics of edge placement error (EPE) and Process Variation Bands (PVBands), together with all the mask constrains. Noted in anamorphic OPC, the 45 degree chop is maintained at the mask level to meet mask manufacturing constraints, but results in skewed angle edge in wafer level correction. In this paper, we used both contact (Via/block) patterns and metal patterns for OPC practice. By comparing the EPE of horizontal and vertical patterns with a fixed mask rule check (MRC), and the PVBand, we focus on the challenges and the solutions of OPC with anamorphic High-NA lens.

  15. Reducing the substrate dependent scanner leveling effect in low-k1 contact printing

    NASA Astrophysics Data System (ADS)

    Chang, C. S.; Tseng, C. F.; Huang, C. H.; Yang, Elvis; Yang, T. H.; Chen, K. C.

    2015-03-01

    As the scaling down of design rule for high-density memory device, the small depth of focus (DoF) budget may be deteriorated by focus leveling errors, which arises in unpredicted reflectivity from multilayer structures on the topographic wafer. The leveling sensors of ASML scanner use near infrared (NIR) range wavelength which can penetrate through most of films using in semiconductor fabrication such as photo-resist, bottom anti reflective coating (BARC) and dielectric materials. Consequently, the reflected light from underlying substructures would disturb leveling sensors from accurate leveling. The different pattern densities and layout characteristics between array and periphery of a memory chip are expected to result in different leveling signals. Furthermore, the process dependent variations between wafer central and edge areas are also considered to yield different leveling performances during wafer exposure. In this study, lower blind contact immunity was observed for peripheral contacts comparing to the array contacts especially around wafer edge region. In order to overcome this problem, a series of investigations have been carried out. The wafer edge leveling optimization through circuit dependent focus edge clearance (CDFEC) option doesn't get improvement. Air gauge improved process leveling (AGILE) function of ASML immersion scanner doesn't show improved result either. The ILD uniformity improvement and step height treatments around wafer edge such as edge exclusion of film deposition and bevel etching are also ineffective to mitigate the blind contact problem of peripheral patterns. Altering the etch hard-mask stack is finally found to be an effective approach to alleviate the issue. For instance, through either containing high temperature deposition advanced patterning film (APF) in the hard-mask or inserting higher opaque film such as amorphous Si in between the hard-mask stack.

  16. Masking release with changing fundamental frequency: Electric acoustic stimulation resembles normal hearing subjects.

    PubMed

    Auinger, Alice Barbara; Riss, Dominik; Liepins, Rudolfs; Rader, Tobias; Keck, Tilman; Keintzel, Thomas; Kaider, Alexandra; Baumgartner, Wolf-Dieter; Gstoettner, Wolfgang; Arnoldner, Christoph

    2017-07-01

    It has been shown that patients with electric acoustic stimulation (EAS) perform better in noisy environments than patients with a cochlear implant (CI). One reason for this could be the preserved access to acoustic low-frequency cues including the fundamental frequency (F0). Therefore, our primary aim was to investigate whether users of EAS experience a release from masking with increasing F0 difference between target talker and masking talker. The study comprised 29 patients and consisted of three groups of subjects: EAS users, CI users and normal-hearing listeners (NH). All CI and EAS users were implanted with a MED-EL cochlear implant and had at least 12 months of experience with the implant. Speech perception was assessed with the Oldenburg sentence test (OlSa) using one sentence from the test corpus as speech masker. The F0 in this masking sentence was shifted upwards by 4, 8, or 12 semitones. For each of these masker conditions the speech reception threshold (SRT) was assessed by adaptively varying the masker level while presenting the target sentences at a fixed level. A statistically significant improvement in speech perception was found for increasing difference in F0 between target sentence and masker sentence in EAS users (p = 0.038) and in NH listeners (p = 0.003). In CI users (classic CI or EAS users with electrical stimulation only) speech perception was independent from differences in F0 between target and masker. A release from masking with increasing difference in F0 between target and masking speech was only observed in listeners and configurations in which the low-frequency region was presented acoustically. Thus, the speech information contained in the low frequencies seems to be crucial for allowing listeners to separate multiple sources. By combining acoustic and electric information, EAS users even manage tasks as complicated as segregating the audio streams from multiple talkers. Preserving the natural code, like fine-structure cues in the low-frequency region, seems to be crucial to provide CI users with the best benefit. Copyright © 2017 Elsevier B.V. All rights reserved.

  17. Dead space variability of face masks for valved holding chambers.

    PubMed

    Amirav, Israel; Newhouse, Michael T

    2008-03-01

    Valved holding chambers with masks are commonly used to deliver inhaled medications to young children with asthma. Optimal mask properties such as their dead space volume have received little attention. The smaller the mask the more likely it is that a greater proportion of the dose in the VHC will be inhaled with each breath, thus speeding VHC emptying and improving overall aerosol delivery efficiency and dose. Masks may have different DSV and thus different performance. To compare both physical dead space and functional dead space of different face masks under various applied pressures. The DSV of three commonly used face masks of VHCs was measured by water displacement both under various pressures (to simulate real-life application, dynamic DSV) and under no pressure (static DSV). There was a great variability of both static and dynamic dead space among various face mask for VHCs, which is probably related to their flexibility. Different masks have different DSV characteristics. This variability should be taken into account when comparing the clinical efficacy of various VHCs.

  18. "The Mask Who Wasn't There": Visual Masking Effect with the Perceptual Absence of the Mask

    ERIC Educational Resources Information Center

    Rey, Amandine Eve; Riou, Benoit; Muller, Dominique; Dabic, Stéphanie; Versace, Rémy

    2015-01-01

    Does a visual mask need to be perceptually present to disrupt processing? In the present research, we proposed to explore the link between perceptual and memory mechanisms by demonstrating that a typical sensory phenomenon (visual masking) can be replicated at a memory level. Experiment 1 highlighted an interference effect of a visual mask on the…

  19. Musicians and non-musicians are equally adept at perceiving masked speech

    PubMed Central

    Boebinger, Dana; Evans, Samuel; Scott, Sophie K.; Rosen, Stuart; Lima, César F.; Manly, Tom

    2015-01-01

    There is much interest in the idea that musicians perform better than non-musicians in understanding speech in background noise. Research in this area has often used energetic maskers, which have their effects primarily at the auditory periphery. However, masking interference can also occur at more central auditory levels, known as informational masking. This experiment extends existing research by using multiple maskers that vary in their informational content and similarity to speech, in order to examine differences in perception of masked speech between trained musicians (n = 25) and non-musicians (n = 25). Although musicians outperformed non-musicians on a measure of frequency discrimination, they showed no advantage in perceiving masked speech. Further analysis revealed that nonverbal IQ, rather than musicianship, significantly predicted speech reception thresholds in noise. The results strongly suggest that the contribution of general cognitive abilities needs to be taken into account in any investigations of individual variability for perceiving speech in noise. PMID:25618067

  20. Assessment of a respiratory face mask for capturing air pollutants and pathogens including human influenza and rhinoviruses.

    PubMed

    Zhou, S Steve; Lukula, Salimatu; Chiossone, Cory; Nims, Raymond W; Suchmann, Donna B; Ijaz, M Khalid

    2018-03-01

    Prevention of infection with airborne pathogens and exposure to airborne particulates and aerosols (environmental pollutants and allergens) can be facilitated through use of disposable face masks. The effectiveness of such masks for excluding pathogens and pollutants is dependent on the intrinsic ability of the masks to resist penetration by airborne contaminants. This study evaluated the relative contributions of a mask, valve, and Micro Ventilator on aerosol filtration efficiency of a new N95 respiratory face mask. The test mask was challenged, using standardized methods, with influenza A and rhinovirus type 14, bacteriophage ΦΧ174, Staphylococcus aureus ( S . aureus ), and model pollutants. The statistical significance of results obtained for different challenge microbial agents and for different mask configurations (masks with operational or nonoperational ventilation fans and masks with sealed Smart Valves) was assessed. The results demonstrate >99.7% efficiency of each test mask configuration for exclusion of influenza A virus, rhinovirus 14, and S . aureus and >99.3% efficiency for paraffin oil and sodium chloride (surrogates for PM 2.5 ). Statistically significant differences in effectiveness of the different mask configurations were not identified. The efficiencies of the masks for excluding smaller-size (i.e., rhinovirus and bacteriophage ΦΧ174) vs. larger-size microbial agents (influenza virus, S . aureus ) were not significantly different. The masks, with or without features intended for enhancing comfort, provide protection against both small- and large-size pathogens. Importantly, the mask appears to be highly efficient for filtration of pathogens, including influenza and rhinoviruses, as well as the fine particulates (PM 2.5 ) present in aerosols that represent a greater challenge for many types of dental and surgical masks. This renders this individual-use N95 respiratory mask an improvement over the former types of masks for protection against a variety of environmental contaminants including PM 2.5 and pathogens such as influenza and rhinoviruses.

  1. Assessment of a respiratory face mask for capturing air pollutants and pathogens including human influenza and rhinoviruses

    PubMed Central

    Zhou, S. Steve; Lukula, Salimatu; Chiossone, Cory; Nims, Raymond W.; Suchmann, Donna B.

    2018-01-01

    Background Prevention of infection with airborne pathogens and exposure to airborne particulates and aerosols (environmental pollutants and allergens) can be facilitated through use of disposable face masks. The effectiveness of such masks for excluding pathogens and pollutants is dependent on the intrinsic ability of the masks to resist penetration by airborne contaminants. This study evaluated the relative contributions of a mask, valve, and Micro Ventilator on aerosol filtration efficiency of a new N95 respiratory face mask. Methods The test mask was challenged, using standardized methods, with influenza A and rhinovirus type 14, bacteriophage ΦΧ174, Staphylococcus aureus (S. aureus), and model pollutants. The statistical significance of results obtained for different challenge microbial agents and for different mask configurations (masks with operational or nonoperational ventilation fans and masks with sealed Smart Valves) was assessed. Results The results demonstrate >99.7% efficiency of each test mask configuration for exclusion of influenza A virus, rhinovirus 14, and S. aureus and >99.3% efficiency for paraffin oil and sodium chloride (surrogates for PM2.5). Statistically significant differences in effectiveness of the different mask configurations were not identified. The efficiencies of the masks for excluding smaller-size (i.e., rhinovirus and bacteriophage ΦΧ174) vs. larger-size microbial agents (influenza virus, S. aureus) were not significantly different. Conclusions The masks, with or without features intended for enhancing comfort, provide protection against both small- and large-size pathogens. Importantly, the mask appears to be highly efficient for filtration of pathogens, including influenza and rhinoviruses, as well as the fine particulates (PM2.5) present in aerosols that represent a greater challenge for many types of dental and surgical masks. This renders this individual-use N95 respiratory mask an improvement over the former types of masks for protection against a variety of environmental contaminants including PM2.5 and pathogens such as influenza and rhinoviruses. PMID:29707364

  2. Updating Landsat-derived land-cover maps using change detection and masking techniques

    NASA Technical Reports Server (NTRS)

    Likens, W.; Maw, K.

    1982-01-01

    The California Integrated Remote Sensing System's San Bernardino County Project was devised to study the utilization of a data base at a number of jurisdictional levels. The present paper discusses the implementation of change-detection and masking techniques in the updating of Landsat-derived land-cover maps. A baseline landcover classification was first created from a 1976 image, then the adjusted 1976 image was compared with a 1979 scene by the techniques of (1) multidate image classification, (2) difference image-distribution tails thresholding, (3) difference image classification, and (4) multi-dimensional chi-square analysis of a difference image. The union of the results of methods 1, 3 and 4 was used to create a mask of possible change areas between 1976 and 1979, which served to limit analysis of the update image and reduce comparison errors in unchanged areas. The techniques of spatial smoothing of change-detection products, and of combining results of difference change-detection algorithms are also shown to improve Landsat change-detection accuracies.

  3. Preserved subliminal processing and impaired conscious access in schizophrenia

    PubMed Central

    Del Cul, Antoine; Dehaene, Stanislas; Leboyer, Marion

    2006-01-01

    Background Studies of visual backward masking have frequently revealed an elevated masking threshold in schizophrenia. This finding has frequently been interpreted as indicating a low-level visual deficit. However, more recent models suggest that masking may also involve late and higher-level integrative processes, while leaving intact early “bottom-up” visual processing. Objectives We tested the hypothesis that the backward masking deficit in schizophrenia corresponds to a deficit in the late stages of conscious perception, whereas the subliminal processing of masked stimuli is fully preserved. Method 28 patients with schizophrenia and 28 normal controls performed two backward-masking experiments. We used Arabic digits as stimuli and varied quasi-continuously the interval with a subsequent mask, thus allowing us to progressively “unmask” the stimuli. We finely quantified their degree of visibility using both objective and subjective measures to evaluate the threshold duration for access to consciousness. We also studied the priming effect caused by the variably masked numbers on a comparison task performed on a subsequently presented and highly visible target number. Results The threshold delay between digit and mask necessary for the conscious perception of the masked stimulus was longer in patients compared to control subjects. This higher consciousness threshold in patients was confirmed by an objective and a subjective measure, and both measures were highly correlated for patients as well as for controls. However, subliminal priming of masked numbers was effective and identical in patients compared to controls. Conclusions Access to conscious report of masked stimuli is impaired in schizophrenia, while fast bottom-up processing of the same stimuli, as assessed by subliminal priming, is preserved. These findings suggest a high-level origin of the masking deficit in schizophrenia, although they leave open for further research its exact relation to previously identified bottom-up visual processing abnormalities. PMID:17146006

  4. Beneath the District Averages: Intradistrict Differences in Teacher Compensation Expenditures

    ERIC Educational Resources Information Center

    Malkus, Nathaniel

    2012-01-01

    Previous research indicates that typical district budgeting practices mask large between-school teacher compensation expenditures (TCE) differences, that teacher sorting drives those TCE differences, and that TCE differences drive overall resource inequities. While scarce accurate school-level resource data has hindered intradistrict equity…

  5. Temporal phase mask encrypted optical steganography carried by amplified spontaneous emission noise.

    PubMed

    Wu, Ben; Wang, Zhenxing; Shastri, Bhavin J; Chang, Matthew P; Frost, Nicholas A; Prucnal, Paul R

    2014-01-13

    A temporal phase mask encryption method is proposed and experimentally demonstrated to improve the security of the stealth channel in an optical steganography system. The stealth channel is protected in two levels. In the first level, the data is carried by amplified spontaneous emission (ASE) noise, which cannot be detected in either the time domain or spectral domain. In the second level, even if the eavesdropper suspects the existence of the stealth channel, each data bit is covered by a fast changing phase mask. The phase mask code is always combined with the wide band noise from ASE. Without knowing the right phase mask code to recover the stealth data, the eavesdropper can only receive the noise like signal with randomized phase.

  6. Human frequency-following response to speech-like sounds: correlates of off-frequency masking.

    PubMed

    Krishnan, Ananthanarayan; Agrawal, Smita

    2010-01-01

    Off-frequency masking of the second formant by energy at the first formant has been shown to influence both identification and discrimination of the second formant in normal-hearing and hearing-impaired listeners. While both excitatory spread and two-tone suppression have been implicated in this simultaneous masking, their relative contribution has been shown to depend on both the level of the masker and the frequency separation between the probe and the masker. Off-frequency masking effects were evaluated in 10 normal-hearing human adults using the frequency-following response (FFR) to two two-tone approximations of vowel stimuli (/a/ and /u/). In the first experiment, the masking effect of F(1) on F(2) was evaluated by attenuating the level of F(1) relative to a fixed F(2) level. In the second experiment, the masking effect was evaluated by increasing the frequency separation between F(1) and F(2) using F(2) frequency as the variable. Results revealed that both attenuation of the F(1) level, and increasing the frequency separation between F(1) and F(2) increased the magnitude of the FFR component at F(2). These results are consistent with a release from off-frequency masking. Given that the results presented here are for high signal and masker levels and for relatively smaller frequency separation between the masker and the probe, it is possible that both suppression and excitatory spread contributed to the masking effects observed in our data. Copyright2009 S. Karger AG, Basel.

  7. Forward masking of dynamic acoustic intensity: effects of intensity region and end-level.

    PubMed

    Olsen, Kirk N; Stevens, Catherine J

    2012-01-01

    Overestimation of loudness change typically occurs in response to up-ramp auditory stimuli (increasing intensity) relative to down-ramps (decreasing intensity) matched on frequency, duration, and end-level. In the experiment reported, forward masking is used to investigate a sensory component of up-ramp overestimation: persistence of excitation after stimulus presentation. White-noise and synthetic vowel 3.6 s up-ramp and down-ramp maskers were presented over two regions of intensity change (40-60 dB SPL, 60-80 dB SPL). Three participants detected 10 ms 1.5 kHz pure tone signals presented at masker-offset to signal-offset delays of 10, 20, 30, 50, 90, 170 ms. Masking magnitude was significantly greater in response to up-ramps compared with down-ramps for masker-signal delays up to and including 50 ms. When controlling for an end-level recency bias (40-60 dB SPL up-ramp vs 80-60 dB SPL down-ramp), the difference in masking magnitude between up-ramps and down-ramps was not significant at each masker-signal delay. Greater sensory persistence in response to up-ramps is argued to have minimal effect on perceptual overestimation of loudness change when response biases are controlled. An explanation based on sensory adaptation is discussed.

  8. Linguistic contributions to speech-on-speech masking for native and non-native listeners: language familiarity and semantic content.

    PubMed

    Brouwer, Susanne; Van Engen, Kristin J; Calandruccio, Lauren; Bradlow, Ann R

    2012-02-01

    This study examined whether speech-on-speech masking is sensitive to variation in the degree of similarity between the target and the masker speech. Three experiments investigated whether speech-in-speech recognition varies across different background speech languages (English vs Dutch) for both English and Dutch targets, as well as across variation in the semantic content of the background speech (meaningful vs semantically anomalous sentences), and across variation in listener status vis-à-vis the target and masker languages (native, non-native, or unfamiliar). The results showed that the more similar the target speech is to the masker speech (e.g., same vs different language, same vs different levels of semantic content), the greater the interference on speech recognition accuracy. Moreover, the listener's knowledge of the target and the background language modulate the size of the release from masking. These factors had an especially strong effect on masking effectiveness in highly unfavorable listening conditions. Overall this research provided evidence that that the degree of target-masker similarity plays a significant role in speech-in-speech recognition. The results also give insight into how listeners assign their resources differently depending on whether they are listening to their first or second language. © 2012 Acoustical Society of America

  9. Linguistic contributions to speech-on-speech masking for native and non-native listeners: Language familiarity and semantic content

    PubMed Central

    Brouwer, Susanne; Van Engen, Kristin J.; Calandruccio, Lauren; Bradlow, Ann R.

    2012-01-01

    This study examined whether speech-on-speech masking is sensitive to variation in the degree of similarity between the target and the masker speech. Three experiments investigated whether speech-in-speech recognition varies across different background speech languages (English vs Dutch) for both English and Dutch targets, as well as across variation in the semantic content of the background speech (meaningful vs semantically anomalous sentences), and across variation in listener status vis-à-vis the target and masker languages (native, non-native, or unfamiliar). The results showed that the more similar the target speech is to the masker speech (e.g., same vs different language, same vs different levels of semantic content), the greater the interference on speech recognition accuracy. Moreover, the listener’s knowledge of the target and the background language modulate the size of the release from masking. These factors had an especially strong effect on masking effectiveness in highly unfavorable listening conditions. Overall this research provided evidence that that the degree of target-masker similarity plays a significant role in speech-in-speech recognition. The results also give insight into how listeners assign their resources differently depending on whether they are listening to their first or second language. PMID:22352516

  10. Accuracy and performance of 3D mask models in optical projection lithography

    NASA Astrophysics Data System (ADS)

    Agudelo, Viviana; Evanschitzky, Peter; Erdmann, Andreas; Fühner, Tim; Shao, Feng; Limmer, Steffen; Fey, Dietmar

    2011-04-01

    Different mask models have been compared: rigorous electromagnetic field (EMF) modeling, rigorous EMF modeling with decomposition techniques and the thin mask approach (Kirchhoff approach) to simulate optical diffraction from different mask patterns in projection systems for lithography. In addition, each rigorous model was tested for two different formulations for partially coherent imaging: The Hopkins assumption and rigorous simulation of mask diffraction orders for multiple illumination angles. The aim of this work is to closely approximate results of the rigorous EMF method by the thin mask model enhanced with pupil filtering techniques. The validity of this approach for different feature sizes, shapes and illumination conditions is investigated.

  11. Wafer hot spot identification through advanced photomask characterization techniques: part 2

    NASA Astrophysics Data System (ADS)

    Choi, Yohan; Green, Michael; Cho, Young; Ham, Young; Lin, Howard; Lan, Andy; Yang, Richer; Lung, Mike

    2017-03-01

    Historically, 1D metrics such as Mean to Target (MTT) and CD Uniformity (CDU) have been adequate for mask end users to evaluate and predict the mask impact on the wafer process. However, the wafer lithographer's process margin is shrinking at advanced nodes to a point that classical mask CD metrics are no longer adequate to gauge the mask contribution to wafer process error. For example, wafer CDU error at advanced nodes is impacted by mask factors such as 3-dimensional (3D) effects and mask pattern fidelity on sub-resolution assist features (SRAFs) used in Optical Proximity Correction (OPC) models of ever-increasing complexity. To overcome the limitation of 1D metrics, there are numerous on-going industry efforts to better define wafer-predictive metrics through both standard mask metrology and aerial CD methods. Even with these improvements, the industry continues to struggle to define useful correlative metrics that link the mask to final device performance. In part 1 of this work, we utilized advanced mask pattern characterization techniques to extract potential hot spots on the mask and link them, theoretically, to issues with final wafer performance. In this paper, part 2, we complete the work by verifying these techniques at wafer level. The test vehicle (TV) that was used for hot spot detection on the mask in part 1 will be used to expose wafers. The results will be used to verify the mask-level predictions. Finally, wafer performance with predicted and verified mask/wafer condition will be shown as the result of advanced mask characterization. The goal is to maximize mask end user yield through mask-wafer technology harmonization. This harmonization will provide the necessary feedback to determine optimum design, mask specifications, and mask-making conditions for optimal wafer process margin.

  12. Masking of low-frequency signals by high-frequency, high-level narrow bands of noisea

    PubMed Central

    Patra, Harisadhan; Roup, Christina M.; Feth, Lawrence L.

    2011-01-01

    Low-frequency masking by intense high-frequency noise bands, referred to as remote masking (RM), was the first evidence to challenge energy-detection models of signal detection. Its underlying mechanisms remain unknown. RM was measured in five normal-hearing young-adults at 250, 350, 500, and 700 Hz using equal-power, spectrally matched random-phase noise (RPN) and low-noise noise (LNN) narrowband maskers. RM was also measured using equal-power, two-tone complex (TC2) and eight-tone complex (TC8). Maskers were centered at 3000 Hz with one or two equivalent rectangular bandwidths (ERBs). Masker levels varied from 80 to 95 dB sound pressure level in 5 dB steps. LNN produced negligible masking for all conditions. An increase in bandwidth in RPN yielded greater masking over a wider frequency region. Masking for TC2 was limited to 350 and 700 Hz for one ERB but shifted to only 700 Hz for two ERBs. A spread of masking to 500 and 700 Hz was observed for TC8 when the bandwidth was increased from one to two ERBs. Results suggest that high-frequency noise bands at high levels could generate significant low-frequency masking. It is possible that listeners experience significant RM due to the amplification of various competing noises that might have significant implications for speech perception in noise. PMID:21361445

  13. Method for the fabrication of three-dimensional microstructures by deep X-ray lithography

    DOEpatents

    Sweatt, William C.; Christenson, Todd R.

    2005-04-05

    A method for the fabrication of three-dimensional microstructures by deep X-ray lithography (DXRL) comprises a masking process that uses a patterned mask with inclined mask holes and off-normal exposures with a DXRL beam aligned with the inclined mask holes. Microstructural features that are oriented in different directions can be obtained by using multiple off-normal exposures through additional mask holes having different orientations. Various methods can be used to block the non-aligned mask holes from the beam when using multiple exposures. A method for fabricating a precision 3D X-ray mask comprises forming an intermediate mask and a master mask on a common support membrane.

  14. Reliability of measuring half-cycle cervical range of motion may be increased using a spirit level for calibration.

    PubMed

    Wilke, Jan; Niederer, Daniel; Vogt, Lutz; Banzer, Winfried

    2018-02-01

    Assessments of range of motion (ROM) represent an essential part of clinical diagnostics. Ultrasonic movement analyses have been demonstrated to provide reliable results when analyzing complete amplitudes (e.g., flexion-extension). However, due to subjective determination of the starting position, the assessment of half-cycle movements (e.g, flexion only) is less reproducible. The present study aimed to examine the reliability of measuring half-cycle cervical ROM using a spirit level for calibration. 20 healthy subjects (30 ± 12yrs, 7♂, 13♀) participated in the randomized, controlled, cross-over trial. In two testing sessions with one week of wash-out in between, cervical ROM was measured by means of an ultrasonic 3D movement analysis system using a test-retest design (baseline and 5 min post baseline). The sessions differed with reference to the mask carrying the ultrasound markers. It was removed during the 5 min break (mask off) or not (mask on). To determine the resting position, a bull's eye spirit level was used in each measurement. With ICC values of 0.90-0.98 (mask on, p < 0.001) and 0.90 to 0.97 (mask off, p < 0.001), both examined conditions demonstrated excellent test-retest reliability for separating the cycles regarding all movement planes. Cervical ROM during half-cycle movements can be assessed with excellent reliability using a spirit level. In contrast to subjective determination of the starting position, analyzing complete movement planes does not increase reliability. Using a defined and objective zero positioning allows the evaluation of repositioning tasks. Copyright © 2017 Elsevier Ltd. All rights reserved.

  15. Advances in low-defect multilayers for EUVL mask blanks

    NASA Astrophysics Data System (ADS)

    Folta, James A.; Davidson, J. Courtney; Larson, Cindy C.; Walton, Christopher C.; Kearney, Patrick A.

    2002-07-01

    Low-defect multilayer coatings are required to fabricate mask blanks for Extreme Ultraviolet Lithography (EUVL). The mask blanks consist of high reflectance EUV multilayers on low thermal expansion substrates. A defect density of 0.0025 printable defects/cm2 for both the mask substrate and the multilayer is required to provide a mask blank yield of 60 percent. Current low defect multilayer coating technology allows repeated coating-added defect levels of 0.05/cm2 for defects greater than 90 nm polystyrene latex sphere (PSL) equivalent size for lots of 20 substrates. Extended clean operation of the coating system at levels below 0.08/cm2 for 3 months of operation has also been achieved. Two substrates with zero added defects in the quality area have been fabricated, providing an existence proof that ultra low defect coatings are possible. Increasing the ion source-to-target distance from 410 to 560 mm to reduce undesired coating of the ion source caused the defect density to increase to 0.2/cm2. Deposition and etching diagnostic witness substrates and deposition pinhole cameras showed a much higher level of ion beam spillover (ions missing the sputter target) than expected. Future work will quantify beam spillover, and test designs to reduce spillover, if it is confirmed to be the cause of the increased defect level. The LDD system will also be upgraded to allow clean coating of standard format mask substrates. The upgrade will confirm that the low defect process developed on Si wafers is compatible with the standard mask format 152 mm square substrates, and will provide a clean supply of EUVL mask blanks needed to support development of EUVL mask patterning processes and clean mask handling technologies.

  16. Respiratory Source Control Using Surgical Masks With Nanofiber Media

    PubMed Central

    Skaria, Shaji D.; Smaldone, Gerald C.

    2014-01-01

    Background: Potentially infected individuals (‘source’) are sometimes encouraged to use face masks to reduce exposure of their infectious aerosols to others (‘receiver’). To improve compliance with Respiratory Source Control via face mask and therefore reduce receiver exposure, a mask should be comfortable and effective. We tested a novel face mask designed to improve breathability and filtration using nanofiber filtration. Methods: Using radiolabeled test aerosols and a calibrated exposure chamber simulating source to receiver interaction, facepiece function was measured with a life-like ventilated manikin model. Measurements included mask airflow resistance (pressure difference during breathing), filtration, (mask capture of exhaled radiolabeled test aerosols), and exposure (the transfer of ‘infectious’ aerosols from the ‘source’ to a ‘receiver’). Polydisperse aerosols were measured at the source with a mass median aerodynamic diameter of 0.95 µm. Approximately 90% of the particles were <2.0 µm. Tested facepieces included nanofiber prototype surgical masks, conventional surgical masks, and for comparison, an N95-class filtering facepiece respirator (commonly known as an ‘N95 respirator’). Airflow through and around conventional surgical face mask and nanofiber prototype face mask was visualized using Schlieren optical imaging. Results: Airflow resistance [ΔP, cmH2O] across sealed surgical masks (means: 0.1865 and 0.1791 cmH2O) approached that of the N95 (mean: 0.2664 cmH2O). The airflow resistance across the nanofiber face mask whether sealed or not sealed (0.0504 and 0.0311 cmH2O) was significantly reduced in comparison. In addition, ‘infected’ source airflow filtration and receiver exposure levels for nanofiber face masks placed on the source were comparable to that achieved with N95 placed on the source; 98.98% versus 82.68% and 0.0194 versus 0.0557, respectively. Compared to deflection within and around the conventional face masks, Schlieren optical imaging demonstrated enhanced airflow through the nanofiber mask. Conclusions: Substituting nanofiber for conventional filter media significantly reduced face mask airflow resistance directing more airflow through the face mask resulting in enhanced filtration. Respiratory source control efficacy similar to that achieved through the use of an N95 respirator worn by the source and decreased airflow resistance using nanofiber masks may improve compliance and reduce receiver exposure. PMID:24737728

  17. Respiratory source control using surgical masks with nanofiber media.

    PubMed

    Skaria, Shaji D; Smaldone, Gerald C

    2014-07-01

    Potentially infected individuals ('source') are sometimes encouraged to use face masks to reduce exposure of their infectious aerosols to others ('receiver'). To improve compliance with Respiratory Source Control via face mask and therefore reduce receiver exposure, a mask should be comfortable and effective. We tested a novel face mask designed to improve breathability and filtration using nanofiber filtration. Using radiolabeled test aerosols and a calibrated exposure chamber simulating source to receiver interaction, facepiece function was measured with a life-like ventilated manikin model. Measurements included mask airflow resistance (pressure difference during breathing), filtration, (mask capture of exhaled radiolabeled test aerosols), and exposure (the transfer of 'infectious' aerosols from the 'source' to a 'receiver'). Polydisperse aerosols were measured at the source with a mass median aerodynamic diameter of 0.95 µm. Approximately 90% of the particles were <2.0 µm. Tested facepieces included nanofiber prototype surgical masks, conventional surgical masks, and for comparison, an N95-class filtering facepiece respirator (commonly known as an 'N95 respirator'). Airflow through and around conventional surgical face mask and nanofiber prototype face mask was visualized using Schlieren optical imaging. Airflow resistance [ΔP, cmH2O] across sealed surgical masks (means: 0.1865 and 0.1791 cmH2O) approached that of the N95 (mean: 0.2664 cmH2O). The airflow resistance across the nanofiber face mask whether sealed or not sealed (0.0504 and 0.0311 cmH2O) was significantly reduced in comparison. In addition, 'infected' source airflow filtration and receiver exposure levels for nanofiber face masks placed on the source were comparable to that achieved with N95 placed on the source; 98.98% versus 82.68% and 0.0194 versus 0.0557, respectively. Compared to deflection within and around the conventional face masks, Schlieren optical imaging demonstrated enhanced airflow through the nanofiber mask. Substituting nanofiber for conventional filter media significantly reduced face mask airflow resistance directing more airflow through the face mask resulting in enhanced filtration. Respiratory source control efficacy similar to that achieved through the use of an N95 respirator worn by the source and decreased airflow resistance using nanofiber masks may improve compliance and reduce receiver exposure. © The Author 2014. Published by Oxford University Press on behalf of the British Occupational Hygiene Society.

  18. The attentional blink is not affected by backward masking of T2, T2-mask SOA, or level of T2 impoverishment.

    PubMed

    Jannati, Ali; Spalek, Thomas M; Lagroix, Hayley E P; Di Lollo, Vincent

    2012-02-01

    Identification of the second of two targets (T2) is impaired when presented shortly after the first (T1). This attentional blink (AB) is thought to arise from a delay in T2 processing during which T2 is vulnerable to masking. Conventional studies have measured T2 accuracy which is constrained by the 100% ceiling. We avoided this problem by using a dynamic threshold-tracking procedure that is inherently free from ceiling constraints. In two experiments we examined how AB magnitude is affected by three masking-related factors: (a) presence/absence of T2 mask, (b) T2-mask stimulus onset asynchrony (SOA), and (c) level of T2 impoverishment (signal-to-noise ratio [SNR]). In Experiment 1, overall accuracy decreased with T2-mask SOA. The magnitude of the AB, however, was invariant with SOA and with mask presence/absence. Experiment 2 further showed that the AB was invariant with T2 SNR. The relationship among mask presence/absence, SOA, and T2 SNR and the AB is encompassed in a qualitative model.

  19. The efficacy of three different mask styles on a PAP titration night.

    PubMed

    Ebben, Matthew R; Oyegbile, Temitayo; Pollak, Charles P

    2012-06-01

    This study compared the efficacy of three different masks, nasal pillows, nasal masks and full face (oronasal) masks, during a single night of titration with continuous positive airway pressure (CPAP). Fifty five subjects that included men (n=33) and women (n=22) were randomly assigned to one of three masks and underwent a routine titration with incremental CPAP applied through the different masks. CPAP applied through the nasal pillows and nasal mask was equally effective in treating mild, moderate, and severe sleep apnea. However, CPAP applied through the oronasal mask required a significantly higher pressure compared to nasal masks to treat moderately severe (2.8 cm of H(2)O ± 2.1 SD) and severe (6.0 cm of H(2)O ± 3.2 SD) obstructive sleep apnea. CPAP applied with either nasal mask was effective in treating mild, moderate, and severe sleep apnea. The oronasal mask required significantly higher pressures in subjects with moderate to severe disease. Therefore, when changing from a nasal to an oronasal mask, a repeat titration is required to ensure effective treatment of sleep apnea, especially in patients with moderate to severe disease. Copyright © 2012 Elsevier B.V. All rights reserved.

  20. The effectiveness of nasal mask vs face mask ventilation in anesthetized, apneic pediatric subjects over 2 years of age: a randomized controlled trial.

    PubMed

    Itagaki, Taiga; Gubin, Tatyana A; Sayal, Puneet; Jiang, Yandong; Kacmarek, Robert M; Anderson, Thomas Anthony

    2016-02-01

    We hypothesized that anesthetized, apneic children could be ventilated equivalently or more efficiently by nasal mask ventilation (NMV) than face mask ventilation (FMV). The aim of this randomized controlled study was to test this hypothesis by comparing the expiratory tidal volume (Vte) between NMV and FMV. After the induction of anesthesia, 41 subjects, 3-17 years of age without anticipated difficult mask ventilation, were randomly assigned to receive either NMV or FMV with neck extension. Both groups were ventilated with pressure control ventilation (PCV) at 20 cmH2 O of peak inspiratory pressure (PIP) with positive end-expiratory pressure (PEEP) levels of 0, 5, and 10 cmH2 O. An additional mouth closing maneuver (MCM) was applied for the NMV group. The Vte was higher in the FMV group compared with the NMV group (median difference [95% CI]: 8.4 [5.5-11.6] ml·kg(-1) ; P < 0.001) when MCM was not applied. NMV achieved less PEEP than FMV (median difference [95% CI]: 5.0 [4.3-5.3] cmH2 O at 10 cmH2 O; P < 0.001) though both groups achieved the set PIP level. In the NMV group, MCM markedly increased Vte (median increase [95% CI]: 5.9 [2.5-9.0] ml·kg(-1) ; P < 0.005) and PEEP (median increase [95% CI]: 5.0 [0.6-8.6] cmH2 O at 10 cmH2 O; P < 0.005); however, PEEP was highly variable and lower than that of FMV (median difference [95% CI]: 2.5 [0.8-8.5] cmH2 O at 10 cmH2 O; P < 0.05). In anesthetized, apneic children greater than 2 years of age ventilated with an anesthesia ventilator and neck extension, FMV established a greater Vte than NMV regardless of mouth status. NMV could not maintain the set PEEP level due to an air leak from the mouth. The MCM increased the Vte and PEEP. © 2016 John Wiley & Sons Ltd.

  1. Categorical information influences conscious perception: An interaction between object-substitution masking and repetition blindness.

    PubMed

    Goodhew, Stephanie C; Greenwood, John A; Edwards, Mark

    2016-05-01

    The visual system is constantly bombarded with dynamic input. In this context, the creation of enduring object representations presents a particular challenge. We used object-substitution masking (OSM) as a tool to probe these processes. In particular, we examined the effect of target-like stimulus repetitions on OSM. In visual crowding, the presentation of a physically identical stimulus to the target reduces crowding and improves target perception, whereas in spatial repetition blindness, the presentation of a stimulus that belongs to the same category (type) as the target impairs perception. Across two experiments, we found an interaction between spatial repetition blindness and OSM, such that repeating a same-type stimulus as the target increased masking magnitude relative to presentation of a different-type stimulus. These results are discussed in the context of the formation of object files. Moreover, the fact that the inducer only had to belong to the same "type" as the target in order to exacerbate masking, without necessarily being physically identical to the target, has important implications for our understanding of OSM per se. That is, our results show the target is processed to a categorical level in OSM despite effective masking and, strikingly, demonstrate that this category-level content directly influences whether or not the target is perceived, not just performance on another task (as in priming).

  2. Recovery of a crowded object by masking the flankers: Determining the locus of feature integration

    PubMed Central

    Chakravarthi, Ramakrishna; Cavanagh, Patrick

    2009-01-01

    Object recognition is a central function of the visual system. As a first step, the features of an object are registered; these independently encoded features are then bound together to form a single representation. Here we investigate the locus of this “feature integration” by examining crowding, a striking breakdown of this process. Crowding, an inability to identify a peripheral target surrounded by flankers, results from “excessive integration” of target and flanker features. We presented a standard crowding display with a target C flanked by four flanker C's in the periphery. We then masked only the flankers (but not the target) with one of three kinds of masks—noise, metacontrast, and object substitution—each of which interferes at progressively higher levels of visual processing. With noise and metacontrast masks (low-level masking), the crowded target was recovered, whereas with object substitution masks (high-level masking), it was not. This places a clear upper bound on the locus of interference in crowding suggesting that crowding is not a low-level phenomenon. We conclude that feature integration, which underlies crowding, occurs prior to the locus of object substitution masking. Further, our results indicate that the integrity of the flankers, but not their identification, is crucial for crowding to occur. PMID:19810785

  3. Equivalence of nasal and oronasal masks during initial CPAP titration for obstructive sleep apnea syndrome.

    PubMed

    Teo, Ming; Amis, Terence; Lee, Sharon; Falland, Karina; Lambert, Stephen; Wheatley, John

    2011-07-01

    Continuous positive airway pressure (CPAP) titration studies are commonly performed using a nasal mask but some patients may prefer a full-face or oronasal mask. There is little evidence regarding the equivalence of different mask interfaces used to initiate treatment. We hypothesized that oronasal breathing when using an oronasal mask increases upper airway collapsibility and that a higher pressure may be required to maintain airway patency. We also assessed patient preferences for the 2 mask interfaces. Prospective, randomized, cross-over design with 2 consecutive CPAP titration nights. Accredited laboratory in a university hospital. Twenty-four treatment-naive subjects with obstructive sleep apnea syndrome and respiratory disturbance index of greater than 15 events per hour. CPAP titration was performed using an auto-titrating machine with randomization to a nasal or oronasal mask, followed by a second titration night using the alternate mask style. There was no significant difference in the mean pressures determined between nasal and oronasal masks, although 43% of subjects had nasal-to-oronasal mask-pressure differences of 2 cm H(2)O or more. Residual respiratory events, arousals, and measured leak were all greater with the oronasal mask. Seventy-nine percent of subjects preferred the nasal mask. Patients with obstructive sleep apnea syndrome can generally switch between nasal and oronasal masks without changing machine pressure, although there are individual differences that may be clinically significant. Measured leak is greater with the oronasal mask. Most patients with obstructive sleep apnea syndrome prefer a nasal mask as the interface for initiation of CPAP. Australian New Zealand Clinical Trials Registry (ANZCTR). ACTRN: ACTRN12611000243910. URL: http://www.ANZCTR.org.au/ACTRN12611000243910.aspx

  4. Effect of mask dead space and occlusion of mask holes on delivery of nebulized albuterol.

    PubMed

    Berlinski, Ariel

    2014-08-01

    Infants and children with respiratory conditions are often prescribed bronchodilators. Face masks are used to facilitate the administration of nebulized therapy in patients unable to use a mouthpiece. Masks incorporate holes into their design, and their occlusion during aerosol delivery has been a common practice. Masks are available in different sizes and different dead volumes. The aim of this study was to compare the effect of different degrees of occlusion of the mask holes and different mask dead space on the amount of nebulized albuterol available at the mouth opening in a model of a spontaneously breathing child. A breathing simulator mimicking infant (tidal volume [VT] = 50 mL, breathing frequency = 30 breaths/min, inspiratory-expiratory ratio [I:E] = 1:3), child (VT = 155 mL, breathing frequency = 25 breaths/min, I:E = 1:2), and adult (VT = 500 mL, breathing frequency = 15 breaths/min, I:E = 1:2) breathing patterns was connected to a collection filter hidden behind a face plate. A pediatric size mask and an adult size mask connected to a continuous output jet nebulizer were sealed to the face plate. Three nebulizers were loaded with albuterol sulfate (2.5 mg/3 mL) and operated with 6 L/min compressed air for 5 min. Experiments were repeated with different degrees of occlusion (0%, 50%, and 90%). Albuterol was extracted from the filter and measured with a spectrophotometer at 276 nm. Occlusion of the holes in the large mask did not increase the amount of albuterol in any of the breathing patterns. The amount of albuterol captured at the mouth opening did not change when the small mask was switched to the large mask, except with the breathing pattern of a child, and when the holes in the mask were 50% occluded (P = .02). Neither decreasing the dead space of the mask nor occluding the mask holes increased the amount of nebulized albuterol captured at the mouth opening.

  5. Effect of Three Different Core Materials on Masking Ability of a Zirconia Ceramic.

    PubMed

    Tabatabaian, Farhad; Masoomi, Faeze; Namdari, Mahshid; Mahshid, Minoo

    2016-09-01

    Masking ability of a restorative material plays a role in hiding colored substructures; however, the masking ability of zirconia ceramic (ZRC) has not yet been clearly understood in zirconia-based restorations. This study evaluated the effect of three different core materials on masking ability of a ZRC. Ten zirconia disc samples, 0.5mm in thickness and 10mm in diameter, were fabricated. A white (W) substrate (control) and three substrates of nickel-chromium alloy (NCA), non-precious gold alloy (NPGA), and ZRC were prepared. The zirconia discs were placed on the four types of substrates for spectrophotometry. The L*, a*, and b* values of the specimens were measured by a spectrophotometer and color change (ΔE) values were calculated to determine color differences between the test and control groups and were then compared with the perceptual threshold. Randomized block ANOVA and Bonferroni test analyzed the data. A significance level of 0.05 was considered. The mean and standard deviation values of ΔE for NCA, NPGA, and ZRC groups were 10.26±2.43, 9.45±1.74, and 6.70±1.91 units, respectively. Significant differences were found in the ΔE values between ZRC and the other two experimental groups (NCA and NPGA; P<0.0001 and P=0.001, respectively). The ΔE values for the groups were more than the predetermined perceptual threshold. Within the limitations of this study, it was concluded that the tested ZRC could not well mask the examined core materials.

  6. Mask strategy at International SEMATECH

    NASA Astrophysics Data System (ADS)

    Kimmel, Kurt R.

    2002-08-01

    International SEMATECH (ISMT) is a consortium consisting of 13 leading semiconductor manufacturers from around the globe. Its objective is to develop the infrastructure necessary for its member companies to realize the International Technology Roadmap for Semiconductors (ITRS) through efficiencies of shared development resources and knowledge. The largest area of effort is lithography, recognized as a crucial enabler for microelectronics technology progress. Within the Lithography Division, most of the efforts center on mask-related issues. The development strategy at International SEMATCH will be presented and the interlock of lithography projects clarified. Because of the limited size of the mask production equipment market, the business case is weak for aggressive investment commensurate with the pace of the International Technology Roadmap for Semiconductors. With masks becoming the overwhelming component of lithography cost, new ways of reducing or eliminating mask costs are being explored. Will mask technology survive without a strong business case? Will the mask industry limit the growth of the semiconductor industry? Are advanced masks worth their escalating cost? An analysis of mask cost from the perspective of mask value imparted to the user is presented with examples and generic formulas for the reader to apply independently. A key part to the success for both International SEMATECH and the industry globally will be partnerships on both the local level between mask-maker and mask-user, and the macro level where global collaborations will be necessary to resolve technology development cost challenges.

  7. Modeling and Simulating Multiple Failure Masking enabled by Local Recovery for Stencil-based Applications at Extreme Scales

    DOE PAGES

    Gamell, Marc; Teranishi, Keita; Mayo, Jackson; ...

    2017-04-24

    By obtaining multi-process hard failure resilience at the application level is a key challenge that must be overcome before the promise of exascale can be fully realized. Some previous work has shown that online global recovery can dramatically reduce the overhead of failures when compared to the more traditional approach of terminating the job and restarting it from the last stored checkpoint. If online recovery is performed in a local manner further scalability is enabled, not only due to the intrinsic lower costs of recovering locally, but also due to derived effects when using some application types. In this papermore » we model one such effect, namely multiple failure masking, that manifests when running Stencil parallel computations on an environment when failures are recovered locally. First, the delay propagation shape of one or multiple failures recovered locally is modeled to enable several analyses of the probability of different levels of failure masking under certain Stencil application behaviors. These results indicate that failure masking is an extremely desirable effect at scale which manifestation is more evident and beneficial as the machine size or the failure rate increase.« less

  8. Modeling and Simulating Multiple Failure Masking enabled by Local Recovery for Stencil-based Applications at Extreme Scales

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Gamell, Marc; Teranishi, Keita; Mayo, Jackson

    By obtaining multi-process hard failure resilience at the application level is a key challenge that must be overcome before the promise of exascale can be fully realized. Some previous work has shown that online global recovery can dramatically reduce the overhead of failures when compared to the more traditional approach of terminating the job and restarting it from the last stored checkpoint. If online recovery is performed in a local manner further scalability is enabled, not only due to the intrinsic lower costs of recovering locally, but also due to derived effects when using some application types. In this papermore » we model one such effect, namely multiple failure masking, that manifests when running Stencil parallel computations on an environment when failures are recovered locally. First, the delay propagation shape of one or multiple failures recovered locally is modeled to enable several analyses of the probability of different levels of failure masking under certain Stencil application behaviors. These results indicate that failure masking is an extremely desirable effect at scale which manifestation is more evident and beneficial as the machine size or the failure rate increase.« less

  9. Can comodulation masking release occur when frequency changes could promote perceptual segregation of the on-frequency and flanking bands?

    PubMed

    Verhey, Jesko L; Epp, Bastian; Stasiak, Arkadiusz; Winter, Ian M

    2013-01-01

    A common characteristic of natural sounds is that the level fluctuations in different frequency regions are coherent. The ability of the auditory system to use this comodulation is shown when a sinusoidal signal is masked by a masker centred at the signal frequency (on-frequency masker, OFM) and one or more off-frequency components, commonly referred to as flanking bands (FBs). In general, the threshold of the signal masked by comodulated masker components is lower than when masked by masker components with uncorrelated envelopes or in the presence of the OFM only. This effect is commonly referred to as comodulation masking release (CMR). The present study investigates if CMR is also observed for a sinusoidal signal embedded in the OFM when the centre frequencies of the FBs are swept over time with a sweep rate of one octave per second. Both a common change of different frequencies and comodulation could serve as cues to indicate which of the stimulus components originate from one source. If the common fate of frequency components is the stronger binding cue, the sweeping FBs and the OFM with a fixed centre frequency should no longer form one auditory object and the CMR should be abolished. However, psychoacoustical results with normal-hearing listeners show that a CMR is also observed with sweeping components. The results are consistent with the hypothesis of wideband inhibition as the underlying physiological mechanism, as the CMR should only depend on the spectral position of the flanking bands relative to the inhibitory areas (as seen in physiological recordings using stationary flanking bands). Preliminary physiological results in the cochlear nucleus of the Guinea pig show that a correlate of CMR can also be found at this level of the auditory pathway with sweeping flanking bands.

  10. Masking overshoot: Effects of ipsilateral, bilateral and contralateral priming

    NASA Astrophysics Data System (ADS)

    Connington, Maureen Catherine

    This study was concerned with masking overshoot, the elevation of the threshold of a brief signal when it is presented at the onset of a masking noise rather than at its temporal center. More specifically, it was concerned with the release from overshoot (i.e., threshold improvement) produced by priming stimuli, presented ipsilaterally, bilaterally and contralaterally at primer- masker gaps of 20, 40 and 80 msec. The more general purpose of the study was to assess the contributions of peripheral and central factors to the overshoot and overshoot-release phenomena. The primers and masking stimuli consisted of white noise bursts of 200 and 400 msec duration, respectively. The probe signal was a 20 msec 4kHz tone. The tone and masker were always presented in one ear. There were, however, 3 modes of primer presentation: ipsilateral, bilateral (identical waveforms to both ears) and contralateral. Three primer-masker gaps of 20, 40 and 80 msec were used. Five normally hearing adults were tested at primer and masker levels of 80 dB HL. Four of the five subjects exhibited significant masking overshoot, when tested without priming. Ipsilateral priming with 20 and 40 msec gaps produced significant masking release from overshoot. Threshold became poorer, however with increasing gap duration and with increasing distance of the perceived primer from the test ear (i.e. ipsilateral priming produced better thresholds than did bilateral priming and bilateral priming produced better thresholds than contralateral priming). There was significant masking enhancement (i.e. threshold was significantly poorer than in the unprimed probe at onset condition) with the contralateral 80 msec primer. The fact that ipsilateral and bilateral primers performed differently does not support the theory that masking overshoot and its release are solely the results of peripheral adaptation. In fact, the group results support the conclusion that masking overshoot is influenced by central factors. However, there were marked inter-subject differences. It seems possible that masking overshoot and its release are influenced by both peripheral adaptation effects and central processes and that the balance between the two is subject-dependent.

  11. Differential effect of visual masking in perceptual categorization.

    PubMed

    Hélie, Sébastien; Cousineau, Denis

    2015-06-01

    This article explores the visual information used to categorize stimuli drawn from a common stimulus space into verbal and nonverbal categories using 2 experiments. Experiment 1 explores the effect of target duration on verbal and nonverbal categorization using backward masking to interrupt visual processing. With categories equated for difficulty for long and short target durations, intermediate target duration shows an advantage for verbal categorization over nonverbal categorization. Experiment 2 tests whether the results of Experiment 1 can be explained by shorter target duration resulting in a smaller signal-to-noise ratio of the categorization stimulus. To test for this possibility, Experiment 2 used integration masking with the same stimuli, categories, and masks as Experiment 1 with a varying level of mask opacity. As predicted, low mask opacity yielded similar results to long target duration while high mask opacity yielded similar results to short target duration. Importantly, intermediate mask opacity produced an advantage for verbal categorization over nonverbal categorization, similar to intermediate target duration. These results suggest that verbal and nonverbal categorization are affected differently by manipulations affecting the signal-to-noise ratio of the stimulus, consistent with multiple-system theories of categorizations. The results further suggest that verbal categorization may be more digital (and more robust to low signal-to-noise ratio) while the information used in nonverbal categorization may be more analog (and less robust to lower signal-to-noise ratio). This article concludes with a discussion of how these new results affect the use of masking in perceptual categorization and multiple-system theories of perceptual category learning. (c) 2015 APA, all rights reserved).

  12. A masked negative self-esteem? Implicit and explicit self-esteem in patients with Narcissistic Personality Disorder.

    PubMed

    Marissen, Marlies A E; Brouwer, Marlies E; Hiemstra, Annemarie M F; Deen, Mathijs L; Franken, Ingmar H A

    2016-08-30

    The mask model of narcissism states that the narcissistic traits of patients with NPD are the result of a compensatory reaction to underlying ego fragility. This model assumes that high explicit self-esteem masks low implicit self-esteem. However, research on narcissism has predominantly focused on non-clinical participants and data derived from patients diagnosed with Narcissistic Personality Disorder (NPD) remain scarce. Therefore, the goal of the present study was to test the mask model hypothesis of narcissism among patients with NPD. Male patients with NPD were compared to patients with other PD's and healthy participants on implicit and explicit self-esteem. NPD patients did not differ in levels of explicit and implicit self-esteem compared to both the psychiatric and the healthy control group. Overall, the current study found no evidence in support of the mask model of narcissism among a clinical group. This implicates that it might not be relevant for clinicians to focus treatment of NPD on an underlying negative self-esteem. Copyright © 2016 Elsevier Ireland Ltd. All rights reserved.

  13. Nasal mask ventilation is better than face mask ventilation in edentulous patients.

    PubMed

    Kapoor, Mukul Chandra; Rana, Sandeep; Singh, Arvind Kumar; Vishal, Vindhya; Sikdar, Indranil

    2016-01-01

    Face mask ventilation of the edentulous patient is often difficult as ineffective seating of the standard mask to the face prevents attainment of an adequate air seal. The efficacy of nasal ventilation in edentulous patients has been cited in case reports but has never been investigated. Consecutive edentulous adult patients scheduled for surgery under general anesthesia with endotracheal intubation, during a 17-month period, were prospectively evaluated. After induction of anesthesia and administration of neuromuscular blocker, lungs were ventilated with a standard anatomical face mask of appropriate size, using a volume controlled anesthesia ventilator with tidal volume set at 10 ml/kg. In case of inadequate ventilation, the mask position was adjusted to achieve best-fit. Inspired and expired tidal volumes were measured. Thereafter, the face mask was replaced by a nasal mask and after achieving best-fit, the inspired and expired tidal volumes were recorded. The difference in expired tidal volumes and airway pressures at best-fit with the use of the two masks and number of patients with inadequate ventilation with use of the masks were statistically analyzed. A total of 79 edentulous patients were recruited for the study. The difference in expiratory tidal volumes with the use of the two masks at best-fit was statistically significant (P = 0.0017). Despite the best-fit mask placement, adequacy of ventilation could not be achieved in 24.1% patients during face mask ventilation, and 12.7% patients during nasal mask ventilation and the difference was statistically significant. Nasal mask ventilation is more efficient than standard face mask ventilation in edentulous patients.

  14. Effectiveness of three just-in-time training modalities for N-95 mask fit testing.

    PubMed

    Jones, David; Stoler, Genevieve; Suyama, Joe

    2013-01-01

    To compare and contrast three different training modalities for fit testing N-95 respirator face masks. Block randomized interventional study. Urban university. Two hundred eighty-nine medical students. Students were randomly assigned to video, lecture, or slide show to evaluate the effectiveness of the methods for fit testing large groups of people. Ease of fit and success of fit for each instructional technique. Mask 1 was a Kimberly-Clark duckbill N-95 respirator mask, and mask 2 was a 3M™ carpenters N-95 respirator mask. "Ease of fit" was defined as the ability to successfully don a mask in less than 30 seconds. "Success of fit" was defined as the ability to correctly don a mask in one try. There were no statistical differences by training modality for either mask regarding ease of fit or success of fit. There were no differences among video presentation, small group demonstration, and self-directed slide show just-in-time training modalities for ease of fit or success of fit N-95 respirator mask fitting. Further study is needed to explore more effective fit training modalities.

  15. Metacontrast masking is processed before grapheme-color synesthesia.

    PubMed

    Bacon, Michael Patrick; Bridgeman, Bruce; Ramachandran, Vilayanur S

    2013-01-01

    We investigated the physiological mechanism of grapheme-color synesthesia using metacontrast masking. A metacontrast target is rendered invisible by a mask that is delayed by about 60 ms; the target and mask do not overlap in space or time. Little masking occurs, however, if the target and mask are simultaneous. This effect must be cortical, because it can be obtained dichoptically. To compare the data for synesthetes and controls, we developed a metacontrast design in which nonsynesthete controls showed weaker dichromatic masking (i.e., the target and mask were in different colors) than monochromatic masking. We accomplished this with an equiluminant target, mask, and background for each observer. If synesthetic color affected metacontrast, synesthetes should show monochromatic masking more similar to the weak dichromatic masking among controls, because synesthetes could add their synesthetic color to the monochromatic condition. The target-mask pairs used for each synesthete were graphemes that elicited strong synesthetic colors. We found stronger monochromatic than dichromatic U-shaped metacontrast for both synesthetes and controls, with optimal masking at an asynchrony of 66 ms. The difference in performance between the monochromatic and dichromatic conditions in the synesthetes indicates that synesthesia occurs at a later processing stage than does metacontrast masking.

  16. Mask etcher data strategy for 45nm and beyond

    NASA Astrophysics Data System (ADS)

    Lewington, Richard; Ibrahim, Ibrahim M.; Panayil, Sheeba; Kumar, Ajay; Yamartino, John

    2006-05-01

    Mask Etching for the 45nm technology node and beyond requires a system-level data and diagnostics strategy. This necessity stems from the need to control the performance of the mask etcher to increasingly stringent and diverse requirements of the mask production environment. Increasing mask costs and the capability to acquire and consolidate a wealth of data within the mask etch platform are primary motivators towards harnessing data mines for feedback into the mask etching optimization. There are offline and real-time possibilities and scenarios. Here, we discuss the data architecture, acquisition, and strategies of the Applied Materials Tetra II TM Mask Etch System.

  17. Comparison of the upper airway dynamics of oronasal and nasal masks with positive airway pressure treatment using cine magnetic resonance imaging.

    PubMed

    Ebben, Matthew R; Milrad, Sara; Dyke, Jonathan P; Phillips, C Douglas; Krieger, Ana C

    2016-03-01

    It is known that oronasal masks are not as effective at opening the upper airway compared to nasal only continuous positive airway pressure (CPAP) masks in patients with sleep-disordered breathing. However, the physiological mechanism for this difference in efficacy is not known; although, it has been hypothesized to involve the retroglossal and/or retropalatal region of the upper airway. The objective of this study was to investigate differences in retroglossal and retropalatal anterior-posterior space with the use of oronasal vs. nasal CPAP masks using real-time cine magnetic resonance imaging (cMRI). Ten subjects (eight men, two women) with obstructive sleep apnea (OSA) were given cMRI with both nasal and oronasal CPAP masks. Each subject was imaged with each interface at pressures of 5, 10, and 15 cm of H2O, while in the supine position along the sagittal plane. The oronasal mask produced significantly less airway opening in the retropalatal region of the upper airway compared to the nasal mask interface. During exhalation, mask style had a significant effect on anterior-posterior distance p = 0.016. No differences were found in the retroglossal region between mask styles. Our study confirmed previous findings showing differences in treatment efficacy between oronasal and nasal mask styles. We have shown anatomic evidence that the nasal mask is more effective in opening the upper airway compared to the oronasal mask in the retropalatal region.

  18. Comparison of the Upper Airway Dynamics of Oronasal and Nasal Masks with Positive Airway Pressure Treatment using cine Magnetic Resonance Imaging

    PubMed Central

    Ebben, Matthew R.; Milrad, Sara; Dyke, Jonathan P.; Phillips, C. Douglas; Krieger, Ana C.

    2016-01-01

    Purpose It is known that oronasal masks are not as effective at opening the upper airway compared to nasal only continuous positive airway pressure (CPAP) masks in patients with sleep disordered breathing. However, the physiological mechanism for this difference in efficacy is not known; although, it has been hypothesized to involve the retroglossal and/or retropalatal region of the upper airway. The objective of this study was to investigate differences in retroglossal and retropalatal anterior-posterior space with the use of oronasal vs. nasal CPAP masks using real-time cine Magnetic Resonance Imaging (cMRI). Methods 10-Subjects (8-men, 2-women) with obstructive sleep apnea (OSA) were given cMRI with both nasal and oronasal CPAP masks. Each subject was imaged with each interface at pressures of 5, 10 and 15 cm of H2O, while in the supine position along the sagittal plane. Results The oronasal mask produced significantly less airway opening in the retropalatal region of the upper airway compared to the nasal mask interface. During exhalation, mask style had a significant effect on anterior-posterior distance p=0.016. No differences were found in the retroglossal region between mask styles. Conclusions Our study confirmed previous findings showing differences in treatment efficacy between oronasal and nasal mask styles. We have shown anatomic evidence that the nasal mask is more effective in opening the upper airway compared to the oronasal mask in the retropalatal region. PMID:25924934

  19. A New MRI Masking Technique Based on Multi-Atlas Brain Segmentation in Controls and Schizophrenia: A Rapid and Viable Alternative to Manual Masking.

    PubMed

    Del Re, Elisabetta C; Gao, Yi; Eckbo, Ryan; Petryshen, Tracey L; Blokland, Gabriëlla A M; Seidman, Larry J; Konishi, Jun; Goldstein, Jill M; McCarley, Robert W; Shenton, Martha E; Bouix, Sylvain

    2016-01-01

    Brain masking of MRI images separates brain from surrounding tissue and its accuracy is important for further imaging analyses. We implemented a new brain masking technique based on multi-atlas brain segmentation (MABS) and compared MABS to masks generated using FreeSurfer (FS; version 5.3), Brain Extraction Tool (BET), and Brainwash, using manually defined masks (MM) as the gold standard. We further determined the effect of different masking techniques on cortical and subcortical volumes generated by FreeSurfer. Images were acquired on a 3-Tesla MR Echospeed system General Electric scanner on five control and five schizophrenia subjects matched on age, sex, and IQ. Automated masks were generated from MABS, FS, BET, and Brainwash, and compared to MM using these metrics: a) volume difference from MM; b) Dice coefficients; and c) intraclass correlation coefficients. Mean volume difference between MM and MABS masks was significantly less than the difference between MM and FS or BET masks. Dice coefficient between MM and MABS was significantly higher than Dice coefficients between MM and FS, BET, or Brainwash. For subcortical and left cortical regions, MABS volumes were closer to MM volumes than were BET or FS volumes. For right cortical regions, MABS volumes were closer to MM volumes than were BET volumes. Brain masks generated using FreeSurfer, BET, and Brainwash are rapidly obtained, but are less accurate than manually defined masks. Masks generated using MABS, in contrast, resemble more closely the gold standard of manual masking, thereby offering a rapid and viable alternative. Copyright © 2015 by the American Society of Neuroimaging.

  20. Equivalence of Nasal and Oronasal Masks during Initial CPAP Titration for Obstructive Sleep Apnea Syndrome

    PubMed Central

    Teo, Ming; Amis, Terence; Lee, Sharon; Falland, Karina; Lambert, Stephen; Wheatley, John

    2011-01-01

    Study Objective: Continuous positive airway pressure (CPAP) titration studies are commonly performed using a nasal mask but some patients may prefer a full-face or oronasal mask. There is little evidence regarding the equivalence of different mask interfaces used to initiate treatment. We hypothesized that oronasal breathing when using an oronasal mask increases upper airway collapsibility and that a higher pressure may be required to maintain airway patency. We also assessed patient preferences for the 2 mask interfaces. Design: Prospective, randomized, cross-over design with 2 consecutive CPAP titration nights. Setting: Accredited laboratory in a university hospital. Patients or Participants: Twenty-four treatment-naive subjects with obstructive sleep apnea syndrome and respiratory disturbance index of greater than 15 events per hour. Interventions: CPAP titration was performed using an auto-titrating machine with randomization to a nasal or oronasal mask, followed by a second titration night using the alternate mask style. Measurements and Results: There was no significant difference in the mean pressures determined between nasal and oronasal masks, although 43% of subjects had nasal-to-oronasal mask-pressure differences of 2 cm H2O or more. Residual respiratory events, arousals, and measured leak were all greater with the oronasal mask. Seventy-nine percent of subjects preferred the nasal mask. Conclusions: Patients with obstructive sleep apnea syndrome can generally switch between nasal and oronasal masks without changing machine pressure, although there are individual differences that may be clinically significant. Measured leak is greater with the oronasal mask. Most patients with obstructive sleep apnea syndrome prefer a nasal mask as the interface for initiation of CPAP. Clinical Trial Registration: Australian New Zealand Clinical Trials Registry (ANZCTR). ACTRN: ACTRN12611000243910. URL: http://www.ANZCTR.org.au/ACTRN12611000243910.aspx Citation: Teo M; Amis T; Lee S; Falland K; Lambert S; Wheatley J. Equivalence of nasal and oronasal masks during initial CPAP titration for obstructive sleep apnea syndrome. SLEEP 2011;34(7):951-955. PMID:21731145

  1. Mask pressure effects on the nasal bridge during short-term noninvasive ventilation

    PubMed Central

    Brill, Anne-Kathrin; Pickersgill, Rachel; Moghal, Mohammad; Morrell, Mary J.; Simonds, Anita K.

    2018-01-01

    The aim of this study was to assess the influence of different masks, ventilator settings and body positions on the pressure exerted on the nasal bridge by the mask and subjective comfort during noninvasive ventilation (NIV). We measured the pressure over the nasal bridge in 20 healthy participants receiving NIV via four different NIV masks (three oronasal masks, one nasal mask) at three different ventilator settings and in the seated or supine position. Objective pressure measurements were obtained with an I-Scan pressure-mapping system. Subjective comfort of the mask fit was assessed with a visual analogue scale. The masks exerted mean pressures between 47.6±29 mmHg and 91.9±42.4 mmHg on the nasal bridge. In the supine position, the pressure was lower in all masks (57.1±31.9 mmHg supine, 63.9±37.3 mmHg seated; p<0.001). With oronasal masks, a change of inspiratory positive airway pressure (IPAP) did not influence the objective pressure over the nasal bridge. Subjective discomfort was associated with higher IPAP and positively correlated with the pressure on the skin. Objective measurement of pressure on the skin during mask fitting might be helpful for mask selection. Mask fitting in the supine position should be considered in the clinical routine. PMID:29637077

  2. Neurophysiological model of tinnitus: dependence of the minimal masking level on treatment outcome.

    PubMed

    Jastreboff, P J; Hazell, J W; Graham, R L

    1994-11-01

    Validity of the neurophysiological model of tinnitus (Jastreboff, 1990), outlined in this paper, was tested on data from multicenter trial of tinnitus masking (Hazell et al., 1985). Minimal masking level, intensity match of tinnitus, and the threshold of hearing have been evaluated on a total of 382 patients before and after 6 months of treatment with maskers, hearing aids, or combination devices. The data has been divided into categories depending on treatment outcome and type of approach used. Results of analysis revealed that: i) the psychoacoustical description of tinnitus does not possess a predictive value for the outcome of the treatment; ii) minimal masking level changed significantly depending on the treatment outcome, decreasing on average by 5.3 dB in patients reporting improvement, and increasing by 4.9 dB in those whose tinnitus remained the same or worsened; iii) 73.9% of patients reporting improvement had their minimal masking level decreased as compared with 50.5% for patients not showing improvement, which is at the level of random change; iv) the type of device used has no significant impact on the treatment outcome and minimal masking level change; v) intensity match and threshold of hearing did not exhibit any significant changes which can be related to treatment outcome. These results are fully consistent with the neurophysiological interpretation of mechanisms involved in the phenomenon of tinnitus and its alleviation.

  3. Measurements of monopolar and bipolar current spreads using forward-masking with a fixed probe.

    PubMed

    Bingabr, Mohamed G; Espinoza-Varas, Blas; Sigdel, Saroj

    2014-05-01

    This research employed a forward-masking paradigm to estimate the current spread of monopolar (MP) and bipolar (BP) maskers, with current amplitudes adjusted to elicit the same loudness. Since the spatial separation between active and return electrodes is smaller in BP than in MP configurations, the BP current spread is more localized and presumably superior in terms of speech intelligibility. Because matching the loudness requires higher current in BP than in MP stimulation, previous forward-masking studies show that BP current spread is not consistently narrower across subjects or electrodes within a subject. The present forward-masking measures of current spread differ from those of previous studies by using the same BP probe electrode configuration for both MP and BP masker configurations, and adjusting the current levels of the MP and BP maskers so as to match them in loudness. With this method, the estimate of masker current spread would not be contaminated by differences in probe current spread. Forward masking was studied in four cochlear implant patients, two females and two males, with speech recognition scores higher than 50%; that is, their auditory-nerve survival status was more than adequate to carry out the experiments. The data showed that MP and BP masker configurations produce equivalent masking patterns (and current spreads) in three participants. A fourth participant displayed asymmetrical patterns with enhancement rather than masking in some cases, especially when the probe and masker were at the same location. This study showed equivalent masking patterns for MP and BP maskers when the BP masker current amplitude was increased to match the loudness of the MP masker, and the same BP probe configuration is used with both maskers. This finding could help to explain why cochlear implant users often fail to accrue higher speech intelligibility benefit from BP stimulation.

  4. In Vitro Comparison of Aerosol Delivery Using Different Face Masks and Flow Rates With a High-Flow Humidity System.

    PubMed

    Lin, Hui-Ling; Harwood, Robert J; Fink, James B; Goodfellow, Lynda T; Ari, Arzu

    2015-09-01

    Aerosol drug delivery to infants and small children is influenced by many factors, such as types of interface, gas flows, and the designs of face masks. The purpose of this in vitro study was to evaluate aerosol delivery during administration of gas flows across the range used clinically with high-flow humidity systems using 2 aerosol masks. A spontaneous lung model was used to simulate an infant/young toddler up to 2 y of age and pediatric breathing patterns. Nebulized salbutamol by a vibrating mesh nebulizer positioned at the inlet of a high-flow humidification system at gas flows of 3, 6, and 12 L/min was delivered via pediatric face masks to a pediatric face mannequin attached to a filter. Aerosol particle size distribution exiting the vibrating mesh nebulizer and at the mask position distal to the heated humidifier with 3 flows was measured with a cascade impactor. Eluted drug from the filters and the impactor was analyzed with a spectrophotometer (n = 3). Statistical analysis was performed by analysis of variance with a significant level of P < .05. The inhaled mass was between 2.8% and 8.1% among all settings and was significantly lower at 12 L/min (P = .004) in the pediatric model. Drug delivery with pediatric breathing was greater than with infant breathing (P = .004). The particle size distribution of aerosol emitted from the nebulizer was larger than the heated humidified aerosol exiting the tubing (P = .002), with no difference between the 3 flows (P = .10). The flows of gas entering the mask and breathing patterns influence aerosol delivery, independent of the face mask used. Aerosol delivery through a high-flow humidification system via mask could be effective with both infant and pediatric breathing patterns. Copyright © 2015 by Daedalus Enterprises.

  5. The Supraglottic Effect of a Reduction in Expiratory Mask Pressure During Continuous Positive Airway Pressure

    PubMed Central

    Masdeu, Maria J.; Patel, Amit V.; Seelall, Vijay; Rapoport, David M.; Ayappa, Indu

    2012-01-01

    Study Objectives: Patients with obstructive sleep apnea may have difficulty exhaling against positive pressure, hence limiting their acceptance of continuous positive airway pressure (CPAP). C-Flex is designed to improve comfort by reducing pressure in the mask during expiration proportionally to expiratory airflow (3 settings correspond to increasing pressure changes). When patients use CPAP, nasal resistance determines how much higher supraglottic pressure is than mask pressure. We hypothesized that increased nasal resistance results in increased expiratory supraglottic pressure swings that could be mitigated by the effects of C-Flex on mask pressure. Design: Cohort study. Setting: Sleep center. Participants: Seventeen patients with obstructive sleep apnea/hypopnea syndrome and a mechanical model of the upper airway. Interventions: In patients on fixed CPAP, CPAP with different C-Flex levels was applied multiple times during the night. In the model, 2 different respiratory patterns and resistances were tested. Measurements and Results: Airflow, expiratory mask, and supraglottic pressures were measured on CPAP and on C-Flex. Swings in pressure during expiration were determined. On CPAP, higher nasal resistance produced greater expiratory pressure swings in the supraglottis in the patients and in the model, as expected. C-Flex 3 produced expiratory drops in mask pressure (range −0.03 to −2.49 cm H2O) but mitigated the expira-tory pressure rise in the supraglottis only during a sinusoidal respiratory pattern in the model. Conclusions: Expiratory changes in mask pressure induced by C-Flex did not uniformly transmit to the supraglottis in either patients with obstructive sleep apnea on CPAP or in a mechanical model of the upper airway with fixed resistance. Data suggest that the observed lack of expiratory drop in supraglottic pressure swings is related to dynamics of the C-Flex algorithm. Citation: Masdeu MJ; Patel AV; Seelall V; Rapoport DM; Ayappa I. The supraglottic effect of a reduction in expiratory mask pressure during continuous positive airway pressure. SLEEP 2012;35(2):263-272. PMID:22294817

  6. Across-channel interference in intensity discrimination: The role of practice and listening strategy

    PubMed Central

    Buss, Emily

    2008-01-01

    Pure tone intensity discrimination thresholds can be elevated by the introduction of remote maskers with roved level. This effect is on the order of 10 dB [10log(ΔI/I)] in some conditions and can be demonstrated under conditions of little or no energetic masking. The current study examined the effect of practice and observer strategy on this phenomenon. Experiment 1 included observers who had no formal experience with intensity discrimination and provided training over six hours on a single masked intensity discrimination task to assess learning effects. Thresholds fell with practice for most observers, with significant improvements in 6 out of 8 cases. Despite these improvements significant masking remained in all cases. The second experiment assessed trial-by-trial effects of roved masker level. Conditional probability of a ‘signal-present’ response as a function of the rove value assigned to each of the two masker tones indicates fundamental differences among observers’ processing strategies, even after six hours of practice. The variability in error patterns across practiced listeners suggests that observers approach the task differently, though this variability does not appear to be related to sensitivity. PMID:18177156

  7. Effects of masker frequency and duration in forward masking: further evidence for the influence of peripheral nonlinearity.

    PubMed

    Oxenham, A J; Plack, C J

    2000-12-01

    Forward masking has often been thought of in terms of neural adaptation, with nonlinearities in the growth and decay of forward masking being accounted for by the nonlinearities inherent in adaptation. In contrast, this study presents further evidence for the hypothesis that forward masking can be described as a linear process, once peripheral, mechanical nonlinearities are taken into account. The first experiment compares the growth of masking for on- and off-frequency maskers. Signal thresholds were measured as a function of masker level for three masker-signal intervals of 0, 10, and 30 ms. The brief 4-kHz sinusoidal signal was masked by a 200-ms sinusoidal forward masker which had a frequency of either 2.4 kHz (off-frequency) or 4 kHz (on-frequency). As in previous studies, for the on-frequency condition, the slope of the function relating signal threshold to masker level became shallower as the delay between the masker and signal was increased. In contrast, the slopes for the off-frequency condition were independent of masker-signal delay and had a value of around unity, indicating linear growth of masking for all masker-signal delays. In the second experiment, a broadband Gaussian noise forward masker was used to mask a brief 6-kHz sinusoidal signal. The spectrum level of the masker was either 0 or 40 dB (re: 20 microPa). The gap between the masker and signal was either 0 or 20 ms. Signal thresholds were measured for masker durations from 5 to 200 ms. The effect of masker duration was found to depend more on signal level than on gap duration or masker level. Overall, the results support the idea that forward masking can be modeled as a linear process, preceded by a static nonlinearity resembling that found on the basilar membrane.

  8. Influence of mask type and mask position on the effectiveness of bag-mask ventilation in a neonatal manikin.

    PubMed

    Deindl, Philipp; O'Reilly, Megan; Zoller, Katharina; Berger, Angelika; Pollak, Arnold; Schwindt, Jens; Schmölzer, Georg M

    2014-01-01

    Anatomical face mask with an air cushion rim might be placed accidentally in a false orientation on the newborn's face or filled with various amounts of air during neonatal resuscitation. Both false orientation as well as variable filling may reduce a tight seal and therefore hamper effective positive pressure ventilation (PPV). We aimed to measure the influence of mask type and mask position on the effectiveness of PPV. Twenty neonatal staff members delivered PPV to a modified, leak-free manikin. Resuscitation parameters were recorded using a self-inflatable bag PPV with an Intersurgical anatomical air cushion rim face mask (IS) and a size 0/1 Laerdal round face mask. Three different positions of the IS were tested: correct position, 90° and 180° rotation in reference to the midline of the face. IS masks in each correct position on the face but with different inflation of the air cushion (empty, 10, 20 and 30 mL). Mask leak was similar with mask rotation to either 90° or 180° but significantly increased from 27 (13-73) % with an adequate filled IS mask compared to 52 (16-83) % with an emptied air cushion rim. Anatomical-shaped face mask had similar mask leaks compared to round face mask. A wrongly positioned anatomical-shaped mask does not influence mask leak. Mask leak significantly increased once the air cushion rim was empty, which may cause failure in mask PPV.

  9. Nasal mask ventilation is better than face mask ventilation in edentulous patients

    PubMed Central

    Kapoor, Mukul Chandra; Rana, Sandeep; Singh, Arvind Kumar; Vishal, Vindhya; Sikdar, Indranil

    2016-01-01

    Background and Aims: Face mask ventilation of the edentulous patient is often difficult as ineffective seating of the standard mask to the face prevents attainment of an adequate air seal. The efficacy of nasal ventilation in edentulous patients has been cited in case reports but has never been investigated. Material and Methods: Consecutive edentulous adult patients scheduled for surgery under general anesthesia with endotracheal intubation, during a 17-month period, were prospectively evaluated. After induction of anesthesia and administration of neuromuscular blocker, lungs were ventilated with a standard anatomical face mask of appropriate size, using a volume controlled anesthesia ventilator with tidal volume set at 10 ml/kg. In case of inadequate ventilation, the mask position was adjusted to achieve best-fit. Inspired and expired tidal volumes were measured. Thereafter, the face mask was replaced by a nasal mask and after achieving best-fit, the inspired and expired tidal volumes were recorded. The difference in expired tidal volumes and airway pressures at best-fit with the use of the two masks and number of patients with inadequate ventilation with use of the masks were statistically analyzed. Results: A total of 79 edentulous patients were recruited for the study. The difference in expiratory tidal volumes with the use of the two masks at best-fit was statistically significant (P = 0.0017). Despite the best-fit mask placement, adequacy of ventilation could not be achieved in 24.1% patients during face mask ventilation, and 12.7% patients during nasal mask ventilation and the difference was statistically significant. Conclusion: Nasal mask ventilation is more efficient than standard face mask ventilation in edentulous patients. PMID:27625477

  10. The mysterious noh mask: contribution of multiple facial parts to the recognition of emotional expressions.

    PubMed

    Miyata, Hiromitsu; Nishimura, Ritsuko; Okanoya, Kazuo; Kawai, Nobuyuki

    2012-01-01

    A Noh mask worn by expert actors when performing on a Japanese traditional Noh drama is suggested to convey countless different facial expressions according to different angles of head/body orientation. The present study addressed the question of how different facial parts of a Noh mask, including the eyebrows, the eyes, and the mouth, may contribute to different emotional expressions. Both experimental situations of active creation and passive recognition of emotional facial expressions were introduced. In Experiment 1, participants either created happy or sad facial expressions, or imitated a face that looked up or down, by actively changing each facial part of a Noh mask image presented on a computer screen. For an upward tilted mask, the eyebrows and the mouth shared common features with sad expressions, whereas the eyes with happy expressions. This contingency tended to be reversed for a downward tilted mask. Experiment 2 further examined which facial parts of a Noh mask are crucial in determining emotional expressions. Participants were exposed to the synthesized Noh mask images with different facial parts expressing different emotions. Results clearly revealed that participants primarily used the shape of the mouth in judging emotions. The facial images having the mouth of an upward/downward tilted Noh mask strongly tended to be evaluated as sad/happy, respectively. The results suggest that Noh masks express chimeric emotional patterns, with different facial parts conveying different emotions This appears consistent with the principles of Noh which highly appreciate subtle and composite emotional expressions, as well as with the mysterious facial expressions observed in Western art. It was further demonstrated that the mouth serves as a diagnostic feature in characterizing the emotional expressions. This indicates the superiority of biologically-driven factors over the traditionally formulated performing styles when evaluating the emotions of the Noh masks.

  11. The Mysterious Noh Mask: Contribution of Multiple Facial Parts to the Recognition of Emotional Expressions

    PubMed Central

    Miyata, Hiromitsu; Nishimura, Ritsuko; Okanoya, Kazuo; Kawai, Nobuyuki

    2012-01-01

    Background A Noh mask worn by expert actors when performing on a Japanese traditional Noh drama is suggested to convey countless different facial expressions according to different angles of head/body orientation. The present study addressed the question of how different facial parts of a Noh mask, including the eyebrows, the eyes, and the mouth, may contribute to different emotional expressions. Both experimental situations of active creation and passive recognition of emotional facial expressions were introduced. Methodology/Principal Findings In Experiment 1, participants either created happy or sad facial expressions, or imitated a face that looked up or down, by actively changing each facial part of a Noh mask image presented on a computer screen. For an upward tilted mask, the eyebrows and the mouth shared common features with sad expressions, whereas the eyes with happy expressions. This contingency tended to be reversed for a downward tilted mask. Experiment 2 further examined which facial parts of a Noh mask are crucial in determining emotional expressions. Participants were exposed to the synthesized Noh mask images with different facial parts expressing different emotions. Results clearly revealed that participants primarily used the shape of the mouth in judging emotions. The facial images having the mouth of an upward/downward tilted Noh mask strongly tended to be evaluated as sad/happy, respectively. Conclusions/Significance The results suggest that Noh masks express chimeric emotional patterns, with different facial parts conveying different emotions This appears consistent with the principles of Noh which highly appreciate subtle and composite emotional expressions, as well as with the mysterious facial expressions observed in Western art. It was further demonstrated that the mouth serves as a diagnostic feature in characterizing the emotional expressions. This indicates the superiority of biologically-driven factors over the traditionally formulated performing styles when evaluating the emotions of the Noh masks. PMID:23185595

  12. Informational masking of speech in children: Effects of ipsilateral and contralateral distracters

    NASA Astrophysics Data System (ADS)

    Wightman, Frederic L.; Kistler, Doris J.

    2005-11-01

    Using a closed-set speech recognition paradigm thought to be heavily influenced by informational masking, auditory selective attention was measured in 38 children (ages 4-16 years) and 8 adults (ages 20-30 years). The task required attention to a monaural target speech message that was presented with a time-synchronized distracter message in the same ear. In some conditions a second distracter message or a speech-shaped noise was presented to the other ear. Compared to adults, children required higher target/distracter ratios to reach comparable performance levels, reflecting more informational masking in these listeners. Informational masking in most conditions was confirmed by the fact that a large proportion of the errors made by the listeners were contained in the distracter message(s). There was a monotonic age effect, such that even the children in the oldest age group (13.6-16 years) demonstrated poorer performance than adults. For both children and adults, presentation of an additional distracter in the contralateral ear significantly reduced performance, even when the distracter messages were produced by a talker of different sex than the target talker. The results are consistent with earlier reports from pure-tone masking studies that informational masking effects are much larger in children than in adults.

  13. Development of Auditory Selective Attention: Why Children Struggle to Hear in Noisy Environments

    PubMed Central

    2015-01-01

    Children’s hearing deteriorates markedly in the presence of unpredictable noise. To explore why, 187 school-age children (4–11 years) and 15 adults performed a tone-in-noise detection task, in which the masking noise varied randomly between every presentation. Selective attention was evaluated by measuring the degree to which listeners were influenced by (i.e., gave weight to) each spectral region of the stimulus. Psychometric fits were also used to estimate levels of internal noise and bias. Levels of masking were found to decrease with age, becoming adult-like by 9–11 years. This change was explained by improvements in selective attention alone, with older listeners better able to ignore noise similar in frequency to the target. Consistent with this, age-related differences in masking were abolished when the noise was made more distant in frequency to the target. This work offers novel evidence that improvements in selective attention are critical for the normal development of auditory judgments. PMID:25706591

  14. Vertical Feature Mask Feature Classification Flag Extraction

    Atmospheric Science Data Center

    2013-03-28

      Vertical Feature Mask Feature Classification Flag Extraction This routine demonstrates extraction of the ... in a CALIPSO Lidar Level 2 Vertical Feature Mask feature classification flag value. It is written in Interactive Data Language (IDL) ...

  15. Impact of different nasal masks on CPAP therapy for obstructive sleep apnea: a randomized comparative trial.

    PubMed

    Neuzeret, Pierre-Charles; Morin, Laurent

    2017-11-01

    Patient interface is important for the success of continuous positive airway pressure (CPAP), but few trials have examined the influence of mask choice on CPAP adherence. To compare the impact of different nasal masks on CPAP in patients with newly-diagnosed obstructive sleep apnea (OSA). OSA patients were randomized in a 2:3 ratio to receive CPAP via different first-line nasal masks: ResMed Mirage FX® (MFX) or control mask (Fisher & Paykel Zest ® , HC407 ® or Philips EasyLife ® ). Mask acceptance, CPAP compliance and Home Care Provider (HCP) interventions were compared between groups after 3 months of CPAP therapy using modified intent-to-treat (mITT; after exclusion of patients with mouth leaks during CPAP initiation) and on-treatment (OT; CPAP adherent) analyses. Of 285 randomized patients, 90 requiring a full-face mask were excluded, leaving 195 and 151 in the mITT and OT analyses, respectively. Mask acceptance rate was higher in the MFX versus control group (mITT: 79% vs 68%, P = 0.067; OT: 90% vs 76%, P = 0.022). CPAP compliance was higher (5.9 ± 1.8 vs 5.1 ± 1.6 h/night, P = 0.011) and nasal mask issue-related HCP visits lower (3% vs 17%, P = 0.006) in the MFX group. Nasal mask failures due to mask discomfort (5% vs 1%) or unintentional leakage (5% vs 0%) were higher in control vs MFX group. Mask acceptance was significantly associated with fewer mask leaks (P = 0.002) and higher pressure therapy (P = 0.042). This study highlights differences between nasal masks for CPAP delivery and shows that initial mask selection can influence adherence and healthcare utilization during CPAP. © 2016 ResMed Germany Inc. The Clinical Respiratory Journal published by John Wiley & Sons Ltd.

  16. Filter penetration and breathing resistance evaluation of respirators and dust masks.

    PubMed

    Ramirez, Joel; O'Shaughnessy, Patrick

    2017-02-01

    The primary objective of this study was to compare the filter performance of a representative selection of uncertified dust masks relative to the filter performance of a set of NIOSH-approved N95 filtering face-piece respirators (FFRs). Five different models of commercially available dust masks were selected for this study. Filter penetration of new dust masks was evaluated against a sodium chloride aerosol. Breathing resistance (BR) of new dust masks and FFRs was then measured for 120 min while challenging the dust masks and FFRs with Arizona road dust (ARD) at 25°C and 30% relative humidity. Results demonstrated that a wide range of maximum filter penetration was observed among the dust masks tested in this study (3-75% at the most penetrating particle size (p < 0.001). The breathing resistances of the unused FFRs and dust masks did not vary greatly (8-13 mm H 2 O) but were significantly different (p < 0.001). After dust loading there was a significant difference between the BR caused by the ARD dust layer on each FFR and dust mask. Microscopic analysis of the external layer of each dust mask and FFR suggests that different collection media in the external layer influences the development of the dust layer and therefore affects the increase in BR differently between the tested models. Two of the dust masks had penetration values < 5% and quality factors (0.26 and 0.33) comparable to those obtained for the two FFRs (0.23 and 0.31). However, the remaining three dust masks, those with penetration > 15%, had quality factors ranging between 0.04-0.15 primarily because their initial BR remained relatively high. These results indicate that some dust masks analysed during this research did not have an expected very low BR to compensate for their high penetration.

  17. Alternating phase-shift mask and binary mask for 45-nm node and beyond: the impact on the mask error control

    NASA Astrophysics Data System (ADS)

    Kojima, Yosuke; Shirasaki, Masanori; Chiba, Kazuaki; Tanaka, Tsuyoshi; Inazuki, Yukio; Yoshikawa, Hiroki; Okazaki, Satoshi; Iwase, Kazuya; Ishikawa, Kiichi; Ozawa, Ken

    2007-05-01

    For 45 nm node and beyond, the alternating phase-shift mask (alt. PSM), one of the most expected resolution enhancement technologies (RET) because of its high image contrast and small mask error enhancement factor (MEEF), and the binary mask (BIM) attract attention. Reducing CD and registration errors and defect are their critical issues. As the solution, the new blank for alt. PSM and BIM is developed. The top film of new blank is thin Cr, and the antireflection film and shielding film composed of MoSi are deposited under the Cr film. The mask CD performance is evaluated for through pitch, CD linearity, CD uniformity, global loading, resolution and pattern fidelity, and the blank performance is evaluated for optical density, reflectivity, sheet resistance, flatness and defect level. It is found that the performance of new blank is equal to or better than that of conventional blank in all items. The mask CD performance shows significant improvement. The lithography performance of new blank is confirmed by wafer printing and AIMS measurement. The full dry type alt. PSM has been used as test plate, and the test results show that new blank can almost meet the specifications of pi-0 CD difference, CD uniformity and process margin for 45 nm node. Additionally, the new blank shows the better pattern fidelity than that of conventional blank on wafer. AIMS results are almost same as wafer results except for the narrowest pattern. Considering the result above, this new blank can reduce the mask error factors of alt. PSM and BIM for 45 nm node and beyond.

  18. Propagation of resist heating mask error to wafer level

    NASA Astrophysics Data System (ADS)

    Babin, S. V.; Karklin, Linard

    2006-10-01

    As technology is approaching 45 nm and below the IC industry is experiencing a severe product yield hit due to rapidly shrinking process windows and unavoidable manufacturing process variations. Current EDA tools are unable by their nature to deliver optimized and process-centered designs that call for 'post design' localized layout optimization DFM tools. To evaluate the impact of different manufacturing process variations on final product it is important to trace and evaluate all errors through design to manufacturing flow. Photo mask is one of the critical parts of this flow, and special attention should be paid to photo mask manufacturing process and especially to mask tight CD control. Electron beam lithography (EBL) is a major technique which is used for fabrication of high-end photo masks. During the writing process, resist heating is one of the sources for mask CD variations. Electron energy is released in the mask body mainly as heat, leading to significant temperature fluctuations in local areas. The temperature fluctuations cause changes in resist sensitivity, which in turn leads to CD variations. These CD variations depend on mask writing speed, order of exposure, pattern density and its distribution. Recent measurements revealed up to 45 nm CD variation on the mask when using ZEP resist. The resist heating problem with CAR resists is significantly smaller compared to other types of resists. This is partially due to higher resist sensitivity and the lower exposure dose required. However, there is no data yet showing CD errors on the wafer induced by CAR resist heating on the mask. This effect can be amplified by high MEEF values and should be carefully evaluated at 45nm and below technology nodes where tight CD control is required. In this paper, we simulated CD variation on the mask due to resist heating; then a mask pattern with the heating error was transferred onto the wafer. So, a CD error on the wafer was evaluated subject to only one term of the mask error budget - the resist heating CD error. In simulation of exposure using a stepper, variable MEEF was considered.

  19. Spatial Selectivity in Cochlear Implants: Effects of Asymmetric Waveforms and Development of a Single-Point Measure.

    PubMed

    Carlyon, Robert P; Deeks, John M; Undurraga, Jaime; Macherey, Olivier; van Wieringen, Astrid

    2017-10-01

    Three experiments studied the extent to which cochlear implant users' spatial selectivity can be manipulated using asymmetric waveforms and tested an efficient method for comparing spatial selectivity produced by different stimuli. Experiment 1 measured forward-masked psychophysical tuning curves (PTCs) for a partial tripolar (pTP) probe. Maskers were presented on bipolar pairs separated by one unused electrode; waveforms were either symmetric biphasic ("SYM") or pseudomonophasic with the short high-amplitude phase being either anodic ("PSA") or cathodic ("PSC") on the more apical electrode. For the SYM masker, several subjects showed PTCs consistent with a bimodal excitation pattern, with discrete excitation peaks on each electrode of the bipolar masker pair. Most subjects showed significant differences between the PSA and PSC maskers consistent with greater masking by the electrode where the high-amplitude phase was anodic, but the pattern differed markedly across subjects. Experiment 2 measured masked excitation patterns for a pTP probe and either a monopolar symmetric biphasic masker ("MP_SYM") or pTP pseudomonophasic maskers where the short high-amplitude phase was either anodic ("TP_PSA") or cathodic ("TP_PSC") on the masker's central electrode. Four of the five subjects showed significant differences between the masker types, but again the pattern varied markedly across subjects. Because the levels of the maskers were chosen to produce the same masking of a probe on the same channel as the masker, it was correctly predicted that maskers that produce broader masking patterns would sound louder. Experiment 3 exploited this finding by using a single-point measure of spread of excitation to reveal significantly better spatial selectivity for TP_PSA compared to TP_PSC maskers.

  20. Clinical evaluation of cochlear implant sound coding taking into account conjectural masking functions, MP3000™.

    PubMed

    Buechner, Andreas; Beynon, Andy; Szyfter, Witold; Niemczyk, Kazimierz; Hoppe, Ulrich; Hey, Matthias; Brokx, Jan; Eyles, Julie; Van de Heyning, Paul; Paludetti, Gaetano; Zarowski, Andrzej; Quaranta, Nicola; Wesarg, Thomas; Festen, Joost; Olze, Heidi; Dhooge, Ingeborg; Müller-Deile, Joachim; Ramos, Angel; Roman, Stephane; Piron, Jean-Pierre; Cuda, Domenico; Burdo, Sandro; Grolman, Wilko; Vaillard, Samantha Roux; Huarte, Alicia; Frachet, Bruno; Morera, Constantine; Garcia-Ibáñez, Luis; Abels, Daniel; Walger, Martin; Müller-Mazotta, Jochen; Leone, Carlo Antonio; Meyer, Bernard; Dillier, Norbert; Steffens, Thomas; Gentine, André; Mazzoli, Manuela; Rypkema, Gerben; Killian, Matthijs; Smoorenburg, Guido

    2011-11-01

    Efficacy of the SPEAK and ACE coding strategies was compared with that of a new strategy, MP3000™, by 37 European implant centers including 221 subjects. The SPEAK and ACE strategies are based on selection of 8-10 spectral components with the highest levels, while MP3000 is based on the selection of only 4-6 components, with the highest levels relative to an estimate of the spread of masking. The pulse rate per component was fixed. No significant difference was found for the speech scores and for coding preference between the SPEAK/ACE and MP3000 strategies. Battery life was 24% longer for the MP3000 strategy. With MP3000 the best results were found for a selection of six components. In addition, the best results were found for a masking function with a low-frequency slope of 50 dB/Bark and a high-frequency slope of 37 dB/Bark (50/37) as compared to the other combinations examined of 40/30 and 20/15 dB/Bark. The best results found for the steepest slopes do not seem to agree with current estimates of the spread of masking in electrical stimulation. Future research might reveal if performance with respect to SPEAK/ACE can be enhanced by increasing the number of channels in MP3000 beyond 4-6 and it should shed more light on the optimum steepness of the slopes of the masking functions applied in MP3000.

  1. Is tinnitus an early voice of masked hypertension? High masked hypertension rate in patients with tinnitus.

    PubMed

    Gun, Taylan; Özkan, Selçuk; Yavuz, Bunyamin

    2018-04-23

    Tinnitus is hearing a sound without any external acoustic stimulus. There are some clues of hypertension can cause tinnitus in different ways. The aim of the study was to evaluate the relationship between tinnitus and masked hypertension including echocardiographic parameters and severity of tinnitus. This study included 88 patients with tinnitus of at least 3 months duration and 85 age and gender-matched control subjects. Tinnitus severity index was used to classify the patients with tinnitus. After a complete medical history, all subjects underwent routine laboratory examination, office blood pressure measurement, hearing tests and ambulatory blood pressure monitoring. Masked hypertension is defined as normal office blood pressure measurement and high ambulatory blood pressure level. Baseline characteristics in patients and controls were similar. Prevalence of masked hypertension was significantly higher in patients with tinnitus than controls (18.2% vs 3.5%, p = 0.002). Office diastolic BP (76 ± 8.1 vs. 72.74 ± 8.68, p = 0.01), ambulatory 24-H diastolic BP (70.2 ± 9.6 vs. 66.9 ± 6.1, p = 0.07) and ambulatory daytime diastolic BP (73.7 ± 9.5 vs. 71.1 ± 6.2, p = 0.03) was significantly higher in patients with tinnitus than control group. Tinnitus severity index in patients without masked hypertension was 0 and tinnitus severity index in patients with masked hypertension were 2 (1-5). This study demonstrated that masked hypertension must be kept in mind if there is a complaint of tinnitus without any other obvious reason.

  2. JAPE 91: Influence of terrain masking of the acoustic propagation of helicopter noise

    NASA Technical Reports Server (NTRS)

    Naz, P.

    1993-01-01

    The acoustic propagation in the case of a noise source masked by a small element of terrain has been investigated experimentally. These data have been measured during the 'terrain masking' experiment of the NATO JAPE 91 experimental campaign. The main objective of that experiment was to study the acoustic detection of a helicopter masked by a small hill. Microphones have been placed at different locations on the shadow zone of the hill to study the effect of the terrain obstruction on sound propagation. The results presented come from data measured by Atlas Elektronik and by ISL, and have been processed together. The terrain obstruction causes an excess attenuation of the SPL (Sound Pressure Level) for all the frequencies, but this attenuation is more effective for the high frequencies than for the low frequencies. Results typical of diffraction phenomena have been observed; the SPL is minimal at the foot of the hill and is relatively constant beyond it.

  3. Impact of input mask signals on delay-based photonic reservoir computing with semiconductor lasers.

    PubMed

    Kuriki, Yoma; Nakayama, Joma; Takano, Kosuke; Uchida, Atsushi

    2018-03-05

    We experimentally investigate delay-based photonic reservoir computing using semiconductor lasers with optical feedback and injection. We apply different types of temporal mask signals, such as digital, chaos, and colored-noise mask signals, as the weights between the input signal and the virtual nodes in the reservoir. We evaluate the performance of reservoir computing by using a time-series prediction task for the different mask signals. The chaos mask signal shows superior performance than that of the digital mask signals. However, similar prediction errors can be achieved for the chaos and colored-noise mask signals. Mask signals with larger amplitudes result in better performance for all mask signals in the range of the amplitude accessible in our experiment. The performance of reservoir computing is strongly dependent on the cut-off frequency of the colored-noise mask signals, which is related to the resonance of the relaxation oscillation frequency of the laser used as the reservoir.

  4. Effective masking levels for 500 and 2000 Hz bone conduction auditory steady state responses in infants and adults with normal hearing.

    PubMed

    Small, Susan A; Smyth, Aisling; Leon, Griselle

    2014-01-01

    Few studies have investigated effective masking levels (EMLs) needed to isolate the test ear for bone conduction assessments in infants. The objective of this study was to determine EMLs for 500 and 2000 Hz bone conduction auditory steady state responses (ASSRs) to amplitude (AM)/frequency-modulated (FM) stimuli for infants and adults with normal hearing. Maturational factors that contribute to infant-adult differences in EMLs will also be investigated. The present study and previously published 1000 and 4000 Hz EML data will be compared to investigate EML across four frequencies. These findings will provide a starting point for implementing clinical masking for infant bone conduction testing using physiological measures. Participants were 15 infants (7 to 35 weeks) and 15 adults (21 to 56 years) with normal hearing. Bone-conducted single ASSR stimuli (research MASTER) were 100% AM and 25% FM at 85 and 101 Hz for 500 and 2000 Hz carrier frequencies, respectively. They were presented at 25 and 35 dB HL for 500 Hz and at 35 and 45 dB HL for 2000 Hz for both infants and adults (approximately 10 and 20 dB SL at each frequency for infants). Air-conducted narrowband maskers were presented to both ears simultaneously. Real-ear to coupler differences were measured to account for differences in the sound pressure developed in infant and adult ear canals as a result of ear-canal size. Data analyses were conducted for mean EMLs across frequency (500 to 4000 Hz) and between age groups. Masked and unmasked ASSR amplitudes were compared for 500 and 2000 Hz. Both infants and adults required much more masking (25 to 33 dB) to eliminate responses at 500 compared with 2000 Hz. On average, infants required 16 dB more masking at 500 Hz and similar amounts of masking at 2000 Hz compared with adults. When adjusted for ear-canal size and bone conduction sensitivity, the pattern of results did not change. Across all four frequencies, infants showed a systematic decrease in mean EMLs with an increase in frequency; all pair-wise comparisons were significant except 2000 versus 4000 Hz. Adults showed smaller frequency-dependent changes in EML (only significantly greater for 500 versus 2000 Hz and 4000 Hz). When ear-canal size and bone conduction sensitivity were taken into account, only 500 Hz required more masking than other frequencies in infants; there were no significant frequency-dependent trends for adults, although the greater EMLs at 1000 versus 2000 Hz and 4000 Hz approached significance. Unmasked and masked amplitudes tended to be larger for 2000 Hz but not for 500 Hz when comparing infants with adults. EMLs appropriate for infants for bone conduction ASSRs elicited to AM/FM stimuli are considerably higher at 500 compared with 2000 Hz. Infants also need more masking at 500 Hz compared with adults but the same amount of masking at 2000 Hz. Comparisons across four frequencies reveal a systematic decrease in EML with an increase in frequency in infants, which is not apparent in adults. Recommended EMLs for AM/FM bone-conducted ASSR stimuli presented at 35 dB HL for 500, 1000, 2000, and 4000 Hz, respectively, are: (1) infants: 81, 68, 59, and 45 dB SPL, and (2) adults: 66, 63, 59, and 55 dB SPL.

  5. Cost-effectiveness analysis of N95 respirators and medical masks to protect healthcare workers in China from respiratory infections.

    PubMed

    Mukerji, Shohini; MacIntyre, C Raina; Seale, Holly; Wang, Quanyi; Yang, Peng; Wang, Xiaoli; Newall, Anthony T

    2017-07-03

    There are substantial differences between the costs of medical masks and N95 respirators. Cost-effectiveness analysis is required to assist decision-makers evaluating alternative healthcare worker (HCW) mask/respirator strategies. This study aims to compare the cost-effectiveness of N95 respirators and medical masks for protecting HCWs in Beijing, China. We developed a cost-effectiveness analysis model utilising efficacy and resource use data from two cluster randomised clinical trials assessing various mask/respirator strategies conducted in HCWs in Level 2 and 3 Beijing hospitals for the 2008-09 and 2009-10 influenza seasons. The main outcome measure was the incremental cost-effectiveness ratio (ICER) per clinical respiratory illness (CRI) case prevented. We used a societal perspective which included intervention costs, the healthcare costs of CRI in HCWs and absenteeism costs. The incremental cost to prevent a CRI case with continuous use of N95 respirators when compared to medical masks ranged from US $490-$1230 (approx. 3000-7600 RMB). One-way sensitivity analysis indicated that the CRI attack rate and intervention effectiveness had the greatest impact on cost-effectiveness. The determination of cost-effectiveness for mask/respirator strategies will depend on the willingness to pay to prevent a CRI case in a HCW, which will vary between countries. In the case of a highly pathogenic pandemic, respirator use in HCWs would likely be a cost-effective intervention.

  6. Determining the energetic and informational components of speech-on-speech masking

    PubMed Central

    Kidd, Gerald; Mason, Christine R.; Swaminathan, Jayaganesh; Roverud, Elin; Clayton, Kameron K.; Best, Virginia

    2016-01-01

    Identification of target speech was studied under masked conditions consisting of two or four independent speech maskers. In the reference conditions, the maskers were colocated with the target, the masker talkers were the same sex as the target, and the masker speech was intelligible. The comparison conditions, intended to provide release from masking, included different-sex target and masker talkers, time-reversal of the masker speech, and spatial separation of the maskers from the target. Significant release from masking was found for all comparison conditions. To determine whether these reductions in masking could be attributed to differences in energetic masking, ideal time-frequency segregation (ITFS) processing was applied so that the time-frequency units where the masker energy dominated the target energy were removed. The remaining target-dominated “glimpses” were reassembled as the stimulus. Speech reception thresholds measured using these resynthesized ITFS-processed stimuli were the same for the reference and comparison conditions supporting the conclusion that the amount of energetic masking across conditions was the same. These results indicated that the large release from masking found under all comparison conditions was due primarily to a reduction in informational masking. Furthermore, the large individual differences observed generally were correlated across the three masking release conditions. PMID:27475139

  7. Nonadditivity of forward and simultaneous maskinga

    PubMed Central

    Svec, Adam; Joshi, Suyash N.; Jesteadt, Walt

    2013-01-01

    The current study measured the additional masking obtained for combinations of forward and simultaneous maskers as a function of forward masker bandwidth, signal delay, and simultaneous masker level. The effects of the two individual maskers were equated in all conditions. Additional masking increased with increasing masker level, increasing signal delay, and decreasing masker bandwidth. The portion of the simultaneous masker that made the greater contribution to additional masking was the part that overlapped with the signal, not with the forward masker. The changes in additional masking observed as a function of forward masker bandwidth and the interaction between the effects of forward and simultaneous maskers call into question the use of additional masking as a measure of basilar membrane compression and present problems for the use of simultaneous noise to simulate hearing loss. PMID:24116423

  8. Spatial release from masking improves sound pattern discrimination along a biologically relevant pulse-rate continuum in gray treefrogs

    PubMed Central

    Ward, Jessica L.; Buerkle, Nathan P.; Bee, Mark A.

    2013-01-01

    Frogs form large choruses during the mating season in which males produce loud advertisement calls to attract females and repel rival males. High background noise levels in these social aggregations can impair vocal perception. In humans, spatial release from masking contributes to our ability to understand speech in noisy social groups. Here, we tested the hypothesis that spatial separation between target signals and ‘chorus-shaped noise’ improves the ability of female gray treefrogs (Hyla chrysoscelis) to perform a behavioral discrimination task based on perceiving differences in the pulsatile structure of advertisement calls. We used two-stimulus choice tests to measure phonotaxis (approach toward sound) in response to calls differing in pulse rate along a biologically relevant continuum between conspecific (50 pulses s−1) and heterospecific (20 pulses s−1) calls. Signals were presented in quiet, in colocated noise, and in spatially separated noise. In quiet conditions, females exhibited robust preferences for calls with relatively faster pulse rates more typical of conspecific calls. Behavioral discrimination between calls differing in pulse rate was impaired in the presence of colocated noise but similar between quiet and spatially separated noise conditions. Our results indicate that spatial release from energetic masking facilitates a biologically important temporal discrimination task in frogs. We discuss these results in light of previous work on spatial release from masking in frogs and other animals. PMID:24055623

  9. Effectiveness of Placebo Therapy for Maintaining Masking in a Clinical Trial of Vergence/Accommodative Therapy

    PubMed Central

    Kulp, Marjean; Mitchell, G. Lynn; Borsting, Eric; Scheiman, Mitchell; Cotter, Susan; Rouse, Michael; Tamkins, Susanna; Mohney, Brian G.; Toole, Andrew; Reuter, Kathleen

    2009-01-01

    Purpose To evaluate the effectiveness of the Convergence Insufficiency Treatment Trial (CITT) placebo therapy program in maintaining masking of patients randomized to the office-based treatment arms, determine whether demographic variables affect masking, and determine whether perception of assigned treatment group was associated with treatment outcome or adherence to treatment. Methods Patients (n = 221, ages, 9–17 years) were randomized to one of four treatment groups, two of which were office-based and masked to treatment (n = 114). The placebo therapy program was designed to appear to be real vergence/accommodative therapy, without stimulating vergence, accommodation, or fine saccades (beyond levels of daily visual activities). After treatment, patients in the office-based groups were asked whether they thought they had received real or placebo therapy and how confident they were in their answers. Results Ninety-three percent of patients assigned to real therapy and 85% assigned to placebo therapy thought they were in the real therapy group (P = 0.17). No significant differences were found between the two groups in adherence to the therapy (P ≥ 0.22 for all comparisons). The percentage of patients who thought they were assigned to real therapy did not differ by age, sex, race, or ethnicity (P > 0.30 for all comparisons). No association was found between patients' perception of group assignment and symptoms or signs at outcome (P ≥ 0.38 for all comparisons). Conclusions The CITT placebo therapy program was effective in maintaining patient masking in this study and therefore may have potential for use in future clinical trials using vergence/accommodative therapy. Masking was not affected by demographic variables. Perception of group assignment was not related to symptoms or signs at outcome (ClinicalTrials.gov number, NCT00338611). PMID:19151384

  10. How much is enough? An analysis of CD measurement amount for mask characterization

    NASA Astrophysics Data System (ADS)

    Ullrich, Albrecht; Richter, Jan

    2009-10-01

    The demands on CD (critical dimension) metrology amount in terms of both reproducibility and measurement uncertainty steadily increase from node to node. Different mask characterization requirements have to be addressed like very small features, unevenly distributed features, contacts, semi-dense structures to name only a few. Usually this enhanced need is met by an increasing number of CD measurements, where the new CD requirements are added to the well established CD characterization recipe. This leads straight forwardly to prolonged cycle times and highly complex evaluation routines. At the same time mask processes are continuously improved to become more stable. The enhanced stability offers potential to actually reduce the number of measurements. Thus, in this work we will start to address the fundamental question of how many CD measurements are needed for mask characterization for a given confidence level. We used analysis of variances (ANOVA) to distinguish various contributors like mask making process, measurement tool stability and measurement methodology. These contributions have been investigated for classical photomask CD specifications e.g. mean to target, CD uniformity, target offset tolerance and x-y bias. We found depending on specification that the importance of the contributors interchanges. Interestingly, not only short and long-term metrology contributions are dominant. Also the number of measurements and their spatial distribution on the mask layout (sampling methodology) can be the most important part of the variance. The knowledge of contributions can be used to optimize the sampling plan. As a major finding, we conclude that there is potential to reduce a significant amount of measurements without loosing confidence at all. Here, full sampling in x and y as well as full sampling for different features can be shortened substantially almost up to 50%.

  11. Inconsistent Effect of Arousal on Early Auditory Perception

    PubMed Central

    Bolders, Anna C.; Band, Guido P. H.; Stallen, Pieter Jan M.

    2017-01-01

    Mood has been shown to influence cognitive performance. However, little is known about the influence of mood on sensory processing, specifically in the auditory domain. With the current study, we sought to investigate how auditory processing of neutral sounds is affected by the mood state of the listener. This was tested in two experiments by measuring masked-auditory detection thresholds before and after a standard mood-induction procedure. In the first experiment (N = 76), mood was induced by imagining a mood-appropriate event combined with listening to mood inducing music. In the second experiment (N = 80), imagining was combined with affective picture viewing to exclude any possibility of confounding the results by acoustic properties of the music. In both experiments, the thresholds were determined by means of an adaptive staircase tracking method in a two-interval forced-choice task. Masked detection thresholds were compared between participants in four different moods (calm, happy, sad, and anxious), which enabled differentiation of mood effects along the dimensions arousal and pleasure. Results of the two experiments were analyzed both in separate analyses and in a combined analysis. The first experiment showed that, while there was no impact of pleasure level on the masked threshold, lower arousal was associated with lower threshold (higher masked sensitivity). However, as indicated by an interaction effect between experiment and arousal, arousal did have a different effect on the threshold in Experiment 2. Experiment 2 showed a trend of arousal in opposite direction. These results show that the effect of arousal on auditory-masked sensitivity may depend on the modality of the mood-inducing stimuli. As clear conclusions regarding the genuineness of the arousal effect on the masked threshold cannot be drawn, suggestions for further research that could clarify this issue are provided. PMID:28424639

  12. Nasal vs Oronasal CPAP for OSA Treatment: A Meta-Analysis.

    PubMed

    Andrade, Rafaela G S; Viana, Fernanda M; Nascimento, Juliana A; Drager, Luciano F; Moffa, Adriano; Brunoni, André R; Genta, Pedro R; Lorenzi-Filho, Geraldo

    2018-03-01

    Nasal CPAP is the "gold standard" treatment for OSA. However, oronasal masks are frequently used in clinical practice. The aim of this study was to perform a meta-analysis of all randomized and nonrandomized trials that compared nasal vs oronasal masks on CPAP level, residual apnea-hypopnea index (AHI), and CPAP adherence to treat OSA. The Cochrane Central Register of Controlled Trials, Medline, and Web of Science were searched for relevant studies in any language with the following terms: "sleep apnea" and "CPAP" or "sleep apnea" and "oronasal mask" or "OSA" and "oronasal CPAP" or "oronasal mask" and "adherence." Studies on CPAP treatment for OSA were included, based on the following criteria: (1) original article; (2) randomized or nonrandomized trials; and (3) comparison between nasal and oronasal CPAP including pressure level, and/or residual AHI, and/or CPAP adherence. We identified five randomized and eight nonrandomized trials (4,563 patients) that reported CPAP level and/or residual AHI and/or CPAP adherence. Overall, the random-effects meta-analysis revealed that as compared with nasal, oronasal masks were associated with a significantly higher CPAP level (Hedges' g, -0.59; 95% CI, -0.82 to -0.37; P < .001) (on average, +1.5 cm H 2 O), higher residual AHI (Hedges' g, -0.34; 95% CI, -0.52 to -0.17; P < .001) (+2.8 events/h), and a poorer adherence (Hedges' g, 0.50; 95% CI, 0.21-0.79; P = .001) (-48 min/night). Oronasal masks are associated with a higher CPAP level, higher residual AHI, and poorer adherence than nasal masks. PROSPERO database; No.: CRD42017064584; URL: https://www.crd.york.ac.uk/prospero/. Copyright © 2017 American College of Chest Physicians. Published by Elsevier Inc. All rights reserved.

  13. Competing for Consciousness: Prolonged Mask Exposure Reduces Object Substitution Masking

    ERIC Educational Resources Information Center

    Goodhew, Stephanie C.; Visser, Troy A. W.; Lipp, Ottmar V.; Dux, Paul E.

    2011-01-01

    In object substitution masking (OSM) a sparse, temporally trailing 4-dot mask impairs target identification, even though it has different contours from, and does not spatially overlap with the target. Here, we demonstrate a previously unknown characteristic of OSM: Observers show reduced masking at prolonged (e.g., 640 ms) relative to intermediate…

  14. The Influence of Linguistic Proficiency on Masked Text Recognition Performance in Adults With and Without Congenital Hearing Impairment.

    PubMed

    Huysmans, Elke; Bolk, Elske; Zekveld, Adriana A; Festen, Joost M; de Groot, Annette M B; Goverts, S Theo

    2016-01-01

    The authors first examined the influence of moderate to severe congenital hearing impairment (CHI) on the correctness of samples of elicited spoken language. Then, the authors used this measure as an indicator of linguistic proficiency and examined its effect on performance in language reception, independent of bottom-up auditory processing. In groups of adults with normal hearing (NH, n = 22), acquired hearing impairment (AHI, n = 22), and moderate to severe CHI (n = 21), the authors assessed linguistic proficiency by analyzing the morphosyntactic correctness of their spoken language production. Language reception skills were examined with a task for masked sentence recognition in the visual domain (text), at a readability level of 50%, using grammatically correct sentences and sentences with distorted morphosyntactic cues. The actual performance on the tasks was compared between groups. Adults with CHI made more morphosyntactic errors in spoken language production than adults with NH, while no differences were observed between the AHI and NH group. This outcome pattern sustained when comparisons were restricted to subgroups of AHI and CHI adults, matched for current auditory speech reception abilities. The data yielded no differences between groups in performance in masked text recognition of grammatically correct sentences in a test condition in which subjects could fully take advantage of their linguistic knowledge. Also, no difference between groups was found in the sensitivity to morphosyntactic distortions when processing short masked sentences, presented visually. These data showed that problems with the correct use of specific morphosyntactic knowledge in spoken language production are a long-term effect of moderate to severe CHI, independent of current auditory processing abilities. However, moderate to severe CHI generally does not impede performance in masked language reception in the visual modality, as measured in this study with short, degraded sentences. Aspects of linguistic proficiency that are affected by CHI thus do not seem to play a role in masked sentence recognition in the visual modality.

  15. Evaluation of setup uncertainties for single-fraction SRS by comparing two different mask-creation methods

    NASA Astrophysics Data System (ADS)

    Baek, Jong Geun; Jang, Hyun Soo; Oh, Young Kee; Lee, Hyun Jeong; Kim, Eng Chan

    2015-07-01

    The purpose of this study was to evaluate the setup uncertainties for single-fraction stereotactic radiosurgery (SF-SRS) based on clinical data with two different mask-creation methods using pretreatment con-beam computed tomography imaging guidance. Dedicated frameless fixation Brain- LAB masks for 23 patients were created as a routine mask (R-mask) making method, as explained in the BrainLAB's user manual. Alternative masks (A-masks), which were created by modifying the cover range of the R-masks for the patient's head, were used for 23 patients. The systematic errors including these for each mask and stereotactic target localizer were analyzed, and the errors were calculated as the means ± standard deviations (SD) from the left-right (LR), superior-inferior (SI), anterior-posterior (AP), and yaw setup corrections. In addition, the frequencies of the threedimensional (3D) vector length were analyzed. The values of the mean setup corrections for the R-mask in all directions were < 0.7 mm and < 0.1°, whereas the magnitudes of the SDs were relatively large compared to the mean values. In contrast, the means and SDs of the A-mask were smaller than those for the R-mask with the exception of the SD in the AP direction. The means and SDs in the yaw rotational direction for the R-mask and the A-mask system were comparable. 3D vector shifts of larger magnitude occurred more frequently for the R-mask than the A-mask. The setup uncertainties for each mask with the stereotactic localizing system had an asymmetric offset towards the positive AP direction. The A-mask-creation method, which is capable of covering the top of the patient's head, is superior to that for the R-mask, so the use of the A-mask is encouraged for SF-SRS to reduce the setup uncertainties. Moreover, careful mask-making is required to prevent possible setup uncertainties.

  16. Effects of immobilization mask material on surface dose

    PubMed Central

    Hadley, Scott W.; Kelly, Robin; Lam, Kwok

    2005-01-01

    This work investigates the increase in surface dose caused by thermoplastic masks used for patient positioning and immobilization. A thermoplastic mask is custom fit by stretching a heated mask over the patient at the time of treatment simulation. This mask is then used at treatment to increase the reproducibility of the patient position. The skin sparing effect of mega‐voltage X‐ray beams can be reduced when the patient's skin surface is under the mask material. The sheet of thermoplastic mask has holes to reduce this effect and is available from one manufacturer with two different sizes of holes, one larger than the other. This work investigates the increase in surface dose caused by the mask material and quantifies the difference between the two samples of masks available. The change in the dose buildup was measured using an Attix parallel plate chamber by measuring tissue maximum ratios (TMRs) using solid water. Measurements were made with and without the mask material on the surface of the solid water for 6‐MV and 15‐MV X‐ray beams. The effective thickness of equivalent water was estimated from the TMR curves, and the increase in surface dose was estimated. The buildup effect was measured to be equivalent to 2.2 mm to 0.6 mm for masks that have been stretched by different amounts. The surface dose was estimated to change from 16% and 12% for 6 MV and 15 MV, respectively, to 27% to 61% for 6 MV and 18% to 40% for 15 MV with the mask samples. PACS number: 87.53.Dq PMID:15770192

  17. [Laryngeal mask].

    PubMed

    Villaverde Rozados, María José; Mos Reguera, M Esther; González Argibay, M Concepción; Sixto Gato, Sandra; Radío, Beatriz Alfonso; Fernández Díaz, María José

    2003-11-01

    A laryngeal mask is a very useful instrument to use both in easy as well as difficult handling situations related to the air tract. This mask is placed in the pharynx and it permits a patient to breathe in different modes, either spontaneously or mechanically. Different models are available; some even facilitate the tracheal intubation through the mask. The authors highlight that this type of mask does not protect nor isolate the air tract. As advantages, the authors point out its easy installation; thus, it is an alternative when an air tract presents difficulties; therefore, it is necessary that all personnel who have to deal with the air tract be aware of this mask and know how to handle it.

  18. How color, regularity, and good Gestalt determine backward masking.

    PubMed

    Sayim, Bilge; Manassi, Mauro; Herzog, Michael

    2014-06-18

    The strength of visual backward masking depends on the stimulus onset asynchrony (SOA) between target and mask. Recently, it was shown that the conjoint spatial layout of target and mask is as crucial as SOA. Particularly, masking strength depends on whether target and mask group with each other. The same is true in crowding where the global spatial layout of the flankers and target-flanker grouping determine crowding strength. Here, we presented a vernier target followed by different flanker configurations at varying SOAs. Similar to crowding, masking of a red vernier target was strongly reduced for arrays of 10 green compared with 10 red flanking lines. Unlike crowding, single green lines flanking the red vernier showed strong masking. Irregularly arranged flanking lines yielded stronger masking than did regularly arranged lines, again similar to crowding. While cuboid flankers reduced crowding compared with single lines, this was not the case in masking. We propose that, first, masking is reduced when the flankers are part of a larger spatial structure. Second, spatial factors counteract color differences between the target and the flankers. Third, complex Gestalts, such as cuboids, seem to need longer processing times to show ungrouping effects as observed in crowding. Strong parallels between masking and crowding suggest similar underlying mechanism; however, temporal factors in masking additionally modulate performance, acting as an additional grouping cue. © 2014 ARVO.

  19. Mask manufacturing improvement through capability definition and bottleneck line management

    NASA Astrophysics Data System (ADS)

    Strott, Al

    1994-02-01

    In 1989, Intel's internal mask operation limited itself to research and development activities and re-inspection and pellicle application of externally manufactured masks. Recognizing the rising capital cost of mask manufacturing at the leading edge, Intel's Mask Operation management decided to offset some of these costs by manufacturing more masks internally. This was the beginning of the challenge they set to manufacture at least 50% of Intel's mask volume internally, at world class performance levels. The first step in responding to this challenge was the completion of a comprehensive operation capability analysis. A series of bottleneck improvements by focus teams resulted in an average cycle time improvement to less than five days on all product and less than two days on critical products.

  20. Clean induced feature CD shift of EUV mask

    NASA Astrophysics Data System (ADS)

    Nesládek, Pavel; Schedel, Thorsten; Bender, Markus

    2016-05-01

    EUV developed in the last decade to the most promising <7nm technology candidate. Defects are considered to be one of the most critical issues of the EUV mask. There are several contributors which make the EUV mask so different from the optical one. First one is the significantly more complicated mask stack consisting currently of 40 Mo/Si double layers, covered by Ru capping layer and TaN/TaO absorber/anti-reflective coating on top of the front face of the mask. Backside is in contrary to optical mask covered as well by conductive layer consisting of Cr or CrN. Second contributor is the fact that EUV mask is currently in contrary to optical mask not yet equipped with sealed pellicle, leading to much higher risk of mask contamination. Third reason is use of EUV mask in vacuum, possibly leading to deposition of vacuum contaminants on the EUV mask surface. Latter reason in combination with tight requirements on backside cleanliness lead to the request of frequent recleaning of the EUV mask, in order to sustain mask lifetime similar to that of optical mask. Mask cleaning process alters slightly the surface of any mask - binary COG mask, as well as phase shift mask of any type and naturally also of the EUV mask as well. In case of optical masks the changes are almost negligible, as the mask is exposed to max. 10-20 re-cleans within its life time. These modifications can be expressed in terms of different specified parameters, e.g. CD shift, phase/trans shift, change of the surface roughness etc. The CD shift, expressed as thinning (or exceptionally thickening) of the dark features on the mask is typically in order of magnitude 0.1nm per process run, which is completely acceptable for optical mask. Projected on the lifetime of EUV mask, assuming 100 clean process cycles, this will lead to CD change of about 10nm. For this reason the requirements for EUV mask cleaning are significantly tighter, << 0.1 nm per process run. This task will look even more challenging, when considering, that the tools for CD measurement at the EUV mask are identical as for optical mask. There is one aspect influencing the CD shift, which demands attention. The mask composition of the EUV mask is significantly different from the optical mask. More precisely there are 2 materials influencing the estimated CD in case of EUV mask, whereas there is one material only in case of optical masks, in first approximation. For optical masks, the CD changes can be attributed to modification of the absorber/ARC layer, as the quartz substrate can be hardly modified by the wet process. For EUV Masks chemical modification of the Ru capping layer - thinning, oxidization etc. are rather more probable and we need to take into account, how this effects can influence the CD measurement process. CD changes measured can be interpreted as either change in the feature size, or modification of the chemical nature of both absorber/ARC layer stack and the Ru capping layer. In our work we try to separate the effect of absorber and Ru/capping layer on the CD shift observed and propose independent way of estimation both parameters.

  1. Mask automation: need a revolution in mask makers and equipment industry

    NASA Astrophysics Data System (ADS)

    Moon, Seong-yong; Yu, Sang-yong; Noh, Young-hwa; Son, Ki-jung; Lee, Hyun-Joo; Cho, Han-Ku

    2013-09-01

    As improving device integration for the next generation, high performance and cost down are also required accordingly in semiconductor business. Recently, significant efforts have been given on putting EUV technology into fabrication in order to improve device integration. At the same time, 450mm wafer manufacturing environment has been considered seriously in many ways in order to boost up the productivity. Accordingly, 9-inch mask has been discussed in mask fabrication business recently to support 450mm wafer manufacturing environment successfully. Although introducing 9-inch mask can be crucial for mask industry, multi-beam technology is also expected as another influential turning point to overcome currently the most critical issue in mask industry, electron beam writing time. No matter whether 9-inch mask or multi-beam technology will be employed or not, mask quality and productivity will be the key factors to survive from the device competition. In this paper, the level of facility automation in mask industry is diagnosed and analyzed and the automation guideline is suggested for the next generation.

  2. Development of binary image masks for TPF-C and ground-based AO coronagraphs

    NASA Astrophysics Data System (ADS)

    Ge, Jian; Crepp, Justin; Vanden Heuvel, Andrew; Miller, Shane; McDavitt, Dan; Kravchenko, Ivan; Kuchner, Marc

    2006-06-01

    We report progress on the development of precision binary notch-filter focal plane coronagraphic masks for directly imaging Earth-like planets at visible wavelengths with the Terrestrial Planet Finder Coronagraph (TPF-C), and substellar companions at near infrared wavelengths from the ground with coronagraphs coupled to high-order adaptive optics (AO) systems. Our recent theoretical studies show that 8th-order image masks (Kuchner, Crepp & Ge 2005, KCG05) are capable of achieving unlimited dynamic range in an ideal optical system, while simultaneously remaining relatively insensitive to low-spatial-frequency optical aberrations, such as tip/tilt errors, defocus, coma, astigmatism, etc. These features offer a suite of advantages for the TPF-C by relaxing many control and stability requirements, and can also provide resistance to common practical problems associated with ground-based observations; for example, telescope flexure and low-order errors left uncorrected by the AO system due to wavefront sensor-deformable mirror lag time can leak light at significant levels. Our recent lab experiments show that prototype image masks can generate contrast levels on the order of 2x10 -6 at 3 λ/D and 6x10 -7 at 10 λ/D without deformable mirror correction using monochromatic light (Crepp et al. 2006), and that this contrast is limited primarily by light scattered by imperfections in the optics and extra diffraction created by mask construction errors. These experiments also indicate that the tilt and defocus sensitivities of high-order masks follow the theoretical predictions of Shaklan and Green 2005. In this paper, we discuss these topics as well as review our progress on developing techniques for fabricating a new series of image masks that are "free-standing", as such construction designs may alleviate some of the (mostly chromatic) problems associated with masks that rely on glass substrates for mechanical support. Finally, results obtained from our AO coronagraph simulations are provided in the last section. In particular, we find that: (i) apodized masks provide deeper contrast than hard-edge masks when the image quality exceeds 80% Strehl ratio (SR), (ii) above 90% SR, 4th-order band-limited masks provide higher off-axis throughput than Gaussian masks when generating comparable contrast levels, and (iii) below ~90% SR, hard-edge masks may be better suited for high contrast imaging, since they are less susceptible to tip/tilt alignment errors.

  3. Contribution of Binaural Masking Release to Improved Speech Intelligibility for different Masker types.

    PubMed

    Sutojo, Sarinah; van de Par, Steven; Schoenmaker, Esther

    2018-06-01

    In situations with competing talkers or in the presence of masking noise, speech intelligibility can be improved by spatially separating the target speaker from the interferers. This advantage is generally referred to as spatial release from masking (SRM) and different mechanisms have been suggested to explain it. One proposed mechanism to benefit from spatial cues is the binaural masking release, which is purely stimulus driven. According to this mechanism, the spatial benefit results from differences in the binaural cues of target and masker, which need to appear simultaneously in time and frequency to improve the signal detection. In an alternative proposed mechanism, the differences in the interaural cues improve the segregation of auditory streams, a process, which involves top-down processing rather than being purely stimulus driven. Other than the cues that produce binaural masking release, the interaural cue differences between target and interferer required to improve stream segregation do not have to appear simultaneously in time and frequency. This study is concerned with the contribution of binaural masking release to SRM for three masker types that differ with respect to the amount of energetic masking they exert. Speech intelligibility was measured, employing a stimulus manipulation that inhibits binaural masking release, and analyzed with a metric to account for the number of better-ear glimpses. Results indicate that the contribution of the stimulus-driven binaural masking release plays a minor role while binaural stream segregation and the availability of glimpses in the better ear had a stronger influence on improving the speech intelligibility. This article is protected by copyright. All rights reserved. This article is protected by copyright. All rights reserved.

  4. Development of an Operational Land Water Mask for MODIS Collection 6, and Influence on Downstream Data Products

    NASA Technical Reports Server (NTRS)

    Carroll, M. L.; DiMiceli, C. M.; Townshend, J. R. G.; Sohlberg, R. A.; Elders, A. I.; Devadiga, S.; Sayer, A. M.; Levy, R. C.

    2016-01-01

    Data from the Moderate Resolution Imaging Spectro-radiometer (MODIS)on-board the Earth Observing System Terra and Aqua satellites are processed using a land water mask to determine when an algorithm no longer needs to be run or when an algorithm needs to follow a different pathway. Entering the fourth reprocessing (Collection 6 (C6)) the MODIS team replaced the 1 km water mask with a 500 m water mask for improved representation of the continental surfaces. The new water mask represents more small water bodies for an overall increase in water surface from 1 to 2 of the continental surface. While this is still a small fraction of the overall global surface area the increase is more dramatic in certain areas such as the Arctic and Boreal regions where there are dramatic increases in water surface area in the new mask. MODIS products generated by the on-going C6 reprocessing using the new land water mask show significant impact in areas with high concentrations of change in the land water mask. Here differences between the Collection 5 (C5) and C6 water masks and the impact of these differences on the MOD04 aerosol product and the MOD11 land surface temperature product are shown.

  5. Etch bias inversion during EUV mask ARC etch

    NASA Astrophysics Data System (ADS)

    Lajn, Alexander; Rolff, Haiko; Wistrom, Richard

    2017-07-01

    The introduction of EUV lithography to high volume manufacturing is now within reach for 7nm technology node and beyond (1), at least for some steps. The scheduling is in transition from long to mid-term. Thus, all contributors need to focus their efforts on the production requirements. For the photo mask industry, these requirements include the control of defectivity, CD performance and lifetime of their masks. The mask CD performance including CD uniformity, CD targeting, and CD linearity/ resolution, is predominantly determined by the photo resist performance and by the litho and etch processes. State-of-the-art chemically amplified resists exhibit an asymmetric resolution for directly and indirectly written features, which usually results in a similarly asymmetric resolution performance on the mask. This resolution gap may reach as high as multiple tens of nanometers on the mask level in dependence of the chosen processes. Depending on the printing requirements of the wafer process, a reduction or even an increase of this gap may be required. A potential way of tuning via the etch process, is to control the lateral CD contribution during etch. Aside from process tuning knobs like pressure, RF powers and gases, which usually also affect CD linearity and CD uniformity, the simplest knob is the etch time itself. An increased over etch time results in an increased CD contribution in the normal case. , We found that the etch CD contribution of ARC layer etch on EUV photo masks is reduced by longer over etch times. Moreover, this effect can be demonstrated to be present for different etch chambers and photo resists.

  6. Practicality of performing medical procedures in chemical protective ensembles.

    PubMed

    Garner, Alan; Laurence, Helen; Lee, Anna

    2004-04-01

    To determine whether certain life saving medical procedures can be successfully performed while wearing different levels of personal protective equipment (PPE), and whether these procedures can be performed in a clinically useful time frame. We assessed the capability of eight medical personnel to perform airway maintenance and antidote administration procedures on manikins, in all four described levels of PPE. The levels are: Level A--a fully encapsulated chemically resistant suit; Level B--a chemically resistant suit, gloves and boots with a full-faced positive pressure supplied air respirator; Level C--a chemically resistant splash suit, boots and gloves with an air-purifying positive or negative pressure respirator; Level D--a work uniform. Time in seconds to inflate the lungs of the manikin with bag-valve-mask, laryngeal mask airway (LMA) and endotracheal tube (ETT) were determined, as was the time to secure LMAs and ETTs with either tape or linen ties. Time to insert a cannula in a manikin was also determined. There was a significant difference in time taken to perform procedures in differing levels of personal protective equipment (F21,72 = 1.75, P = 0.04). Significant differences were found in: time to lung inflation using an endotracheal tube (A vs. C mean difference and standard error 75.6 +/- 23.9 s, P = 0.03; A vs. D mean difference and standard error 78.6 +/- 23.9 s, P = 0.03); time to insert a cannula (A vs. D mean difference and standard error 63.6 +/- 11.1 s, P < 0.001; C vs. D mean difference and standard error 40.0 +/- 11.1 s, P = 0.01). A significantly greater time to complete procedures was documented in Level A PPE (fully encapsulated suits) compared with Levels C and D. There was however, no significant difference in times between Level B and Level C. The common practice of equipping hospital and medical staff with only Level C protection should be re-evaluated.

  7. Binaural Advantage for Younger and Older Adults with Normal Hearing

    ERIC Educational Resources Information Center

    Dubno, Judy R.; Ahlstrom, Jayne B.; Horwitz, Amy R.

    2008-01-01

    Purpose: Three experiments measured benefit of spatial separation, benefit of binaural listening, and masking-level differences (MLDs) to assess age-related differences in binaural advantage. Method: Participants were younger and older adults with normal hearing through 4.0 kHz. Experiment 1 compared spatial benefit with and without head shadow.…

  8. Masked response priming in expert typists.

    PubMed

    Heinemann, Alexander; Kiesel, Andrea; Pohl, Carsten; Kunde, Wilfried

    2010-03-01

    In masked priming tasks responses are usually faster when prime and target require identical rather than different responses. Previous research has extensively manipulated the nature and number of response-affording stimuli. However, little is known about the constraints of masked priming regarding the nature and number of response alternatives. The present study explored the limits of masked priming in a six-choice reaction time task, where responses from different fingers of both hands were required. We studied participants that were either experts for the type of response (skilled typists) or novices. Masked primes facilitated responding to targets that required the same response, responses with a different finger of the same hand, and with a homologous finger of the other hand. These effects were modulated by expertise. The results show that masked primes facilitate responding especially for experts in the S-R mapping and with increasing similarity of primed and required response.

  9. Short-term visual deprivation can enhance spatial release from masking.

    PubMed

    Pagé, Sara; Sharp, Andréanne; Landry, Simon P; Champoux, François

    2016-08-15

    This research aims to study the effect of short-term visual deprivation on spatial release from masking, a major component of the cocktail party effect that allows people to detect an auditory target in noise. The Masking Level Difference (MLD) test was administered on healthy individuals over three sessions: before (I) and after 90min of visual deprivation (II), and after 90min of re-exposure to light (III). A non-deprived control group performed the same tests, but remained sighted between sessions I and II. The non-deprived control group displayed constant results across sessions. However, performance in the MLD test was improved following short-term visual deprivation and performance returned to pre-deprivation values after light re-exposure. This study finds that short-term visual deprivation transiently enhances the spatial release from masking. These data suggest the significant potential for enhancing a process involved in the cocktail party effect in normally developing individuals and adds to an emerging literature on the potential to enhance auditory ability after only a brief period of visual deprivation. Copyright © 2016 Elsevier Ireland Ltd. All rights reserved.

  10. Different effects of the two types of spatial pre-cueing: what precisely is "attention" in Di Lollo's and Enns' substitution masking theory?

    PubMed

    Luiga, I; Bachmann, T

    2007-11-01

    Enns and Di Lollo [Psychological Science, 8 (2), 135-139, 1997] have introduced the object substitution theory of visual masking. Object substitution masking occurs when focusing attention on the target is delayed. However, Posner (Quarterly Journal of Experimental Psychology, 32, 3-25, 1980) has already shown that attention can be directed to a target at least in two ways: intentionally (endogenously) and automatically (exogenously). We conducted two experiments to explore the effects of endogenous and exogenous cues on substitution masking. The results showed that when attention was shifted to the target location automatically (using a local peripheral pre-cue), masking was attenuated. A decrease in target identification dependent on a delay of mask offset, typical to substitution masking, was not observed. However, strong substitution masking occurred when the target location was not pre-cued or when attention was directed to the target location intentionally (using a symbolic pre-cue displayed centrally). The hypothesis of two different mechanisms of attentional control in substitution masking was confirmed.

  11. A multicentre phase III randomised controlled single-masked clinical trial evaluating the clinical efficacy and safety of light-masks at preventing dark-adaptation in the treatment of early diabetic macular oedema (CLEOPATRA): study protocol for a randomised controlled trial.

    PubMed

    Sivaprasad, Sobha; Arden, Geoffrey; Prevost, A Toby; Crosby-Nwaobi, Roxanne; Holmes, Helen; Kelly, Joanna; Murphy, Caroline; Rubin, Gary; Vasconcelos, Joanna; Hykin, Philip

    2014-11-22

    This study will evaluate hypoxia, as a novel concept in the pathogenesis of diabetic macular oedema (DMO). As the oxygen demand of the eye is maximum during dark-adaptation, we hypothesize that wearing light-masks during sleep will cause regression and prevent the development and progression of DMO. The study protocol comprises both an efficacy and mechanistic evaluation to test this hypothesis. This is a phase III randomised controlled single-masked multicentre clinical trial to test the clinical efficacy of light-masks at preventing dark-adaptation in the treatment of non-central DMO. Three hundred patients with non-centre-involving DMO in at least one eye will be randomised 1:1 to light-masks and control masks (with no light) to be used during sleep at night for a period of 24 months. The primary outcome is regression of non-central oedema by assessing change in the zone of maximal retinal thickness at baseline on optical coherence tomography (SD-OCT). Secondary outcomes will evaluate the prevention of development and progression of DMO by assessing changes in retinal thickness in different regions of the macula, macular volume, refracted visual acuity and level of retinopathy. Safety parameters will include sleep disturbance. Adverse events and measures of compliance will be assessed over 24 months. Participants recruited to the mechanistic sub-study will have additional retinal oximetry, multifocal electroretinography (ERG) and microperimetry to evaluate the role of hypoxia by assessing and comparing changes induced by supplemental oxygen and the light-masks at 12 months. The outcomes of this study will provide insight into the pathogenesis of DMO and provide evidence on whether a simple, non-invasive device in the form of a light-mask can help prevent the progression to centre-involving DMO and visual impairment in people with diabetes.

  12. Atomic layer deposition-A novel method for the ultrathin coating of minitablets.

    PubMed

    Hautala, Jaana; Kääriäinen, Tommi; Hoppu, Pekka; Kemell, Marianna; Heinämäki, Jyrki; Cameron, David; George, Steven; Juppo, Anne Mari

    2017-10-05

    We introduce atomic layer deposition (ALD) as a novel method for the ultrathin coating (nanolayering) of minitablets. The effects of ALD coating on the tablet characteristics and taste masking were investigated and compared with the established coating method. Minitablets containing bitter tasting denatonium benzoate were coated by ALD using three different TiO 2 nanolayer thicknesses (number of deposition cycles). The established coating of minitablets was performed in a laboratory-scale fluidized-bed apparatus using four concentration levels of aqueous Eudragit ® E coating polymer. The coated minitablets were studied with respect to the surface morphology, taste masking capacity, in vitro disintegration and dissolution, mechanical properties, and uniformity of content. The ALD thin coating resulted in minimal increase in the dimensions and weight of minitablets in comparison to original tablet cores. Surprisingly, ALD coating with TiO 2 nanolayers decreased the mechanical strength, and accelerated the in vitro disintegration of minitablets. Unlike previous studies, the studied levels of TiO 2 nanolayers on tablets were also inadequate for effective taste masking. In summary, ALD permits a simple and rapid method for the ultrathin coating (nanolayering) of minitablets, and provides nanoscale-range TiO 2 coatings on porous minitablets. More research, however, is needed to clarify its potential in tablet taste masking applications. Copyright © 2017 Elsevier B.V. All rights reserved.

  13. Professional and Home-Made Face Masks Reduce Exposure to Respiratory Infections among the General Population

    PubMed Central

    van der Sande, Marianne; Teunis, Peter; Sabel, Rob

    2008-01-01

    Background Governments are preparing for a potential influenza pandemic. Therefore they need data to assess the possible impact of interventions. Face-masks worn by the general population could be an accessible and affordable intervention, if effective when worn under routine circumstances. Methodology We assessed transmission reduction potential provided by personal respirators, surgical masks and home-made masks when worn during a variety of activities by healthy volunteers and a simulated patient. Principal Findings All types of masks reduced aerosol exposure, relatively stable over time, unaffected by duration of wear or type of activity, but with a high degree of individual variation. Personal respirators were more efficient than surgical masks, which were more efficient than home-made masks. Regardless of mask type, children were less well protected. Outward protection (mask wearing by a mechanical head) was less effective than inward protection (mask wearing by healthy volunteers). Conclusions/Significance Any type of general mask use is likely to decrease viral exposure and infection risk on a population level, in spite of imperfect fit and imperfect adherence, personal respirators providing most protection. Masks worn by patients may not offer as great a degree of protection against aerosol transmission. PMID:18612429

  14. Professional and home-made face masks reduce exposure to respiratory infections among the general population.

    PubMed

    van der Sande, Marianne; Teunis, Peter; Sabel, Rob

    2008-07-09

    Governments are preparing for a potential influenza pandemic. Therefore they need data to assess the possible impact of interventions. Face-masks worn by the general population could be an accessible and affordable intervention, if effective when worn under routine circumstances. We assessed transmission reduction potential provided by personal respirators, surgical masks and home-made masks when worn during a variety of activities by healthy volunteers and a simulated patient. All types of masks reduced aerosol exposure, relatively stable over time, unaffected by duration of wear or type of activity, but with a high degree of individual variation. Personal respirators were more efficient than surgical masks, which were more efficient than home-made masks. Regardless of mask type, children were less well protected. Outward protection (mask wearing by a mechanical head) was less effective than inward protection (mask wearing by healthy volunteers). Any type of general mask use is likely to decrease viral exposure and infection risk on a population level, in spite of imperfect fit and imperfect adherence, personal respirators providing most protection. Masks worn by patients may not offer as great a degree of protection against aerosol transmission.

  15. Mask-induced aberration in EUV lithography

    NASA Astrophysics Data System (ADS)

    Nakajima, Yumi; Sato, Takashi; Inanami, Ryoichi; Nakasugi, Tetsuro; Higashiki, Tatsuhiko

    2009-04-01

    We estimated aberrations using Zernike sensitivity analysis. We found the difference of the tolerated aberration with line direction for illumination. The tolerated aberration of perpendicular line for illumination is much smaller than that of parallel line. We consider this difference to be attributable to the mask 3D effect. We call it mask-induced aberration. In the case of the perpendicular line for illumination, there was a difference in CD between right line and left line without aberration. In this report, we discuss the possibility of pattern formation in NA 0.25 generation EUV lithography tool. In perpendicular pattern for EUV light, the dominant part of aberration is mask-induced aberration. In EUV lithography, pattern correction based on the mask topography effect will be more important.

  16. Shadows alter facial expressions of Noh masks.

    PubMed

    Kawai, Nobuyuki; Miyata, Hiromitsu; Nishimura, Ritsuko; Okanoya, Kazuo

    2013-01-01

    A Noh mask, worn by expert actors during performance on the Japanese traditional Noh drama, conveys various emotional expressions despite its fixed physical properties. How does the mask change its expressions? Shadows change subtly during the actual Noh drama, which plays a key role in creating elusive artistic enchantment. We here describe evidence from two experiments regarding how attached shadows of the Noh masks influence the observers' recognition of the emotional expressions. In Experiment 1, neutral-faced Noh masks having the attached shadows of the happy/sad masks were recognized as bearing happy/sad expressions, respectively. This was true for all four types of masks each of which represented a character differing in sex and age, even though the original characteristics of the masks also greatly influenced the evaluation of emotions. Experiment 2 further revealed that frontal Noh mask images having shadows of upward/downward tilted masks were evaluated as sad/happy, respectively. This was consistent with outcomes from preceding studies using actually tilted Noh mask images. Results from the two experiments concur that purely manipulating attached shadows of the different types of Noh masks significantly alters the emotion recognition. These findings go in line with the mysterious facial expressions observed in Western paintings, such as the elusive qualities of Mona Lisa's smile. They also agree with the aesthetic principle of Japanese traditional art "yugen (profound grace and subtlety)", which highly appreciates subtle emotional expressions in the darkness.

  17. The role of off-frequency masking in binaural hearing

    PubMed Central

    Buss, Emily; Hall, Joseph W.

    2010-01-01

    The present studies examined the binaural masking level difference (MLD) for off-frequency masking. It has been shown previously that the MLD decreases steeply with increasing spectral separation between a pure tone signal and a 10-Hz wide band of masking noise. Data collected here show that this reduction in the off-frequency MLD as a function of signal∕masker separation is comparable at 250 and 2500 Hz, indicating that neither interaural phase cues nor frequency resolution are critical to this finding. The MLD decreases more gradually with spectral separation when the masker is a 250-Hz-wide band of noise, a result that implicates the rate of inherent amplitude modulation of the masker. Thresholds were also measured for a brief signal presented coincident with a local masker modulation minimum or maximum. Sensitivity was better in the minima for all NoSπ and off-frequency NoSo conditions, with little or no effect of signal position for on-frequency NoSo conditions. Taken together, the present results indicate that the steep reduction in the off-frequency MLD for a narrowband noise masker is due at least in part to envelope cues in the NoSo conditions. There was no evidence of a reduction in binaural cue quality for off-frequency masking. PMID:20550265

  18. Additivity of nonsimultaneous masking for short Gaussian-shaped sinusoids.

    PubMed

    Laback, Bernhard; Balazs, Peter; Necciari, Thibaud; Savel, Sophie; Ystad, Solvi; Meunier, Sabine; Kronland-Martinet, Richard

    2011-02-01

    The additivity of nonsimultaneous masking was studied using Gaussian-shaped tone pulses (referred to as Gaussians) as masker and target stimuli. Combinations of up to four temporally separated Gaussian maskers with an equivalent rectangular bandwidth of 600 Hz and an equivalent rectangular duration of 1.7 ms were tested. Each masker was level-adjusted to produce approximately 8 dB of masking. Excess masking (exceeding linear additivity) was generally stronger than reported in the literature for longer maskers and comparable target levels. A model incorporating a compressive input/output function, followed by a linear summation stage, underestimated excess masking when using an input/output function derived from literature data for longer maskers and comparable target levels. The data could be predicted with a more compressive input/output function. Stronger compression may be explained by assuming that the Gaussian stimuli were too short to evoke the medial olivocochlear reflex (MOCR), whereas for longer maskers tested previously the MOCR caused reduced compression. Overall, the interpretation of the data suggests strong basilar membrane compression for very short stimuli.

  19. Expanding the printable design space for lithography processes utilizing a cut mask

    NASA Astrophysics Data System (ADS)

    Wandell, Jerome; Salama, Mohamed; Wilkinson, William; Curtice, Mark; Feng, Jui-Hsuan; Gao, Shao Wen; Asthana, Abhishek

    2016-03-01

    The utilization of a cut-mask in semiconductor patterning processes has been in practice for logic devices since the inception of 32nm-node devices, notably with unidirectional gate level printing. However, the microprocessor applications where cut-mask patterning methods are used are expanding as Self-Aligned Double Patterning (SADP) processes become mainstream for 22/14nm fin diffusion, and sub-14nm metal levels. One common weakness for these types of lithography processes is that the initial pattern requiring the follow-up cut-mask typically uses an extreme off-axis imaging source such as dipole to enhance the resolution and line-width roughness (LWR) for critical dense patterns. This source condition suffers from poor process margin in the semi-dense (forbidden pitch) realm and wrong-way directional design spaces. Common pattern failures in these limited design regions include bridging and extra-printing defects that are difficult to resolve with traditional mask improvement means. This forces the device maker to limit the allowable geometries that a designer may use on a device layer. This paper will demonstrate methods to expand the usable design space on dipole-like processes such as unidirectional gate and SADP processes by utilizing the follow-up cut mask to improve the process window. Traditional mask enhancement means for improving the process window in this design realm will be compared to this new cut-mask approach. The unique advantages and disadvantages of the cut-mask solution will be discussed in contrast to those customary methods.

  20. Aerial image metrology for OPC modeling and mask qualification

    NASA Astrophysics Data System (ADS)

    Chen, Ao; Foong, Yee Mei; Thaler, Thomas; Buttgereit, Ute; Chung, Angeline; Burbine, Andrew; Sturtevant, John; Clifford, Chris; Adam, Kostas; De Bisschop, Peter

    2017-06-01

    As nodes become smaller and smaller, the OPC applied to enable these nodes becomes more and more sophisticated. This trend peaks today in curve-linear OPC approaches that are currently starting to appear on the roadmap. With this sophistication of OPC, the mask pattern complexity increases. CD-SEM based mask qualification strategies as they are used today are starting to struggle to provide a precise forecast of the printing behavior of a mask on wafer. An aerial image CD measurement performed on ZEISS Wafer-Level CD system (WLCD) is a complementary approach to mask CD-SEMs to judge the lithographical performance of the mask and its critical production features. The advantage of the aerial image is that it includes all optical effects of the mask such as OPC, SRAF, 3D mask effects, once the image is taken under scanner equivalent illumination conditions. Additionally, it reduces the feature complexity and analyzes the printing relevant CD.

  1. Film loss-free cleaning chemicals for EUV mask lifetime elongation developed through combinatorial chemical screening

    NASA Astrophysics Data System (ADS)

    Choi, Jaehyuck; Kim, Jinsu; Lowe, Jeff; Dattilo, Davide; Koh, Soowan; Choi, Jun Yeol; Dietze, Uwe; Shoki, Tsutomu; Kim, Byung Gook; Jeon, Chan-Uk

    2015-10-01

    EUV masks include many different layers of various materials rarely used in optical masks, and each layer of material has a particular role in enhancing the performance of EUV lithography. Therefore, it is crucial to understand how the mask quality and patterning performance can change during mask fabrication, EUV exposure, maintenance cleaning, shipping, or storage. SPM (Sulfuric acid peroxide mixture) which has been extensively used for acid cleaning of photomask and wafer has serious drawback for EUV mask cleaning. It shows severe film loss of tantalum-based absorber layers and limited removal efficiency of EUV-generated carbon contaminants on EUV mask surface. Here, we introduce such novel cleaning chemicals developed for EUV mask as almost film loss free for various layers of the mask and superior carbon removal performance. Combinatorial chemical screening methods allowed us to screen several hundred combinations of various chemistries and additives under several different process conditions of temperature and time, eventually leading to development of the best chemistry selections for EUV mask cleaning. Recently, there have been many activities for the development of EUV pellicle, driven by ASML and core EUV scanner customer companies. It is still important to obtain film-loss free cleaning chemicals because cleaning cycle of EUV mask should be much faster than that of optic mask mainly due to EUV pellicle lifetime. More frequent cleaning, combined with the adoption of new materials for EUV masks, necessitates that mask manufacturers closely examine the performance change of EUV masks during cleaning process. We have investigated EUV mask quality changes and film losses during 50 cleaning cycles using new chemicals as well as particle and carbon contaminant removal characteristics. We have observed that the performance of new chemicals developed is superior to current SPM or relevant cleaning chemicals for EUV mask cleaning and EUV mask lifetime elongation.

  2. An open-architecture approach to defect analysis software for mask inspection systems

    NASA Astrophysics Data System (ADS)

    Pereira, Mark; Pai, Ravi R.; Reddy, Murali Mohan; Krishna, Ravi M.

    2009-04-01

    Industry data suggests that Mask Inspection represents the second biggest component of Mask Cost and Mask Turn Around Time (TAT). Ever decreasing defect size targets lead to more sensitive mask inspection across the chip, thus generating too many defects. Hence, more operator time is being spent in analyzing and disposition of defects. Also, the fact that multiple Mask Inspection Systems and Defect Analysis strategies would typically be in use in a Mask Shop or a Wafer Foundry further complicates the situation. In this scenario, there is a need for a versatile, user friendly and extensible Defect Analysis software that reduces operator analysis time and enables correct classification and disposition of mask defects by providing intuitive visual and analysis aids. We propose a new vendor-neutral defect analysis software, NxDAT, based on an open architecture. The open architecture of NxDAT makes it easily extensible to support defect analysis for mask inspection systems from different vendors. The capability to load results from mask inspection systems from different vendors either directly or through a common interface enables the functionality of establishing correlation between inspections carried out by mask inspection systems from different vendors. This capability of NxDAT enhances the effectiveness of defect analysis as it directly addresses the real-life scenario where multiple types of mask inspection systems from different vendors co-exist in mask shops or wafer foundries. The open architecture also potentially enables loading wafer inspection results as well as loading data from other related tools such as Review Tools, Repair Tools, CD-SEM tools etc, and correlating them with the corresponding mask inspection results. A unique concept of Plug-In interface to NxDAT further enhances the openness of the architecture of NxDAT by enabling end-users to add their own proprietary defect analysis and image processing algorithms. The plug-in interface makes it possible for the end-users to make use of their collected knowledge through the years of experience in mask inspection process by encapsulating the knowledge into software utilities and plugging them into NxDAT. The plug-in interface is designed with the intent of enabling the pro-active mask defect analysis teams to build competitive differentiation into their defect analysis process while protecting their knowledge internally within their company. By providing interface with all major standard layout and mask data formats, NxDAT enables correlation of defect data on reticles with design and mask databases, further extending the effectiveness of defect analysis for D2DB inspection. NxDAT also includes many other advanced features for easy and fast navigation, visual display of defects, defect selection, multi-tier classification, defect clustering and gridding, sophisticated CD and contact measurement analysis, repeatability analysis such as adder analysis, defect trend, capture rate etc.

  3. Optimizing defect inspection strategy through the use of design-aware database control layers

    NASA Astrophysics Data System (ADS)

    Stoler, Dvori; Ruch, Wayne; Ma, Weimin; Chakravarty, Swapnajit; Liu, Steven; Morgan, Ray; Valadez, John; Moore, Bill; Burns, John

    2007-10-01

    Resolution limitations in the mask making process can cause differences between the features that appear in a database and those printed to a reticle. These differences may result from intentional or unintentional features in the database exceeding the resolution limit of the mask making process such as small gaps or lines in the data, line end shortening on small sub-resolution assist features etc creating challenges to both mask writing and mask inspection. Areas with high variance from design to mask, often referred to as high MEEF areas (mask error enhancement factor), become highly problematic and can directly impact mask and device yield, mask manufacturing cycle time and ultimately mask costs. Specific to mask inspection it may be desirable to inspect certain non-critical or non-relevant features at reduced sensitivity so as not to detect real, but less significant process defects. In contrast there may also be times where increased sensitivity is required for critical mask features or areas. Until recently, this process was extremely manual, creating added time and cost to the mask inspection cycle. Shifting to more intelligent and automated inspection flows is the key focus of this paper. A novel approach to importing design data directly into the mask inspection to include both MDP generated MRC errors files and LRC generated MEEF files. The results of recently developed inspection and review capability based upon controlling defect inspection using design aware data base control layers on a pixel basis are discussed. Typical mask shop applications and implementations will be shown.

  4. [Effect of a surgical mask on six minute walking distance].

    PubMed

    Person, E; Lemercier, C; Royer, A; Reychler, G

    2018-03-01

    Six minutes walking test (6MWT) is regularly used in pulmonology. To minimize the risk of cross-infection, some patients must wear surgical mask at rest and sometimes during exercise. To evaluate the effect of wearing a surgical mask during 6MWT in healthy subjects. It is a prospective study on 44 healthy subjects. After a first 6MWT for training, they performed randomly two 6MWT: with or without a surgical mask. Distance and dyspnea, heart rate and saturation variations were recorded. Distance was not modified by the mask (P=0.99). Dyspnea variation was significantly higher with surgical mask (+5.6 vs. +4.6; P<0.001) and the difference was clinically relevant. No difference was found for the variation of other parameters. Wearing a surgical mask modifies significantly and clinically dyspnea without influencing walked distance. Copyright © 2017 SPLF. Published by Elsevier Masson SAS. All rights reserved.

  5. Psychoacoustic Tinnitus Loudness and Tinnitus-Related Distress Show Different Associations with Oscillatory Brain Activity

    PubMed Central

    Balkenhol, Tobias; Wallhäusser-Franke, Elisabeth; Delb, Wolfgang

    2013-01-01

    Background The phantom auditory perception of subjective tinnitus is associated with aberrant brain activity as evidenced by magneto- and electroencephalographic studies. We tested the hypotheses (1) that psychoacoustically measured tinnitus loudness is related to gamma oscillatory band power, and (2) that tinnitus loudness and tinnitus-related distress are related to distinct brain activity patterns as suggested by the distinction between loudness and distress experienced by tinnitus patients. Furthermore, we explored (3) how hearing impairment, minimum masking level, and (4) psychological comorbidities are related to spontaneous oscillatory brain activity in tinnitus patients. Methods and Findings Resting state oscillatory brain activity recorded electroencephalographically from 46 male tinnitus patients showed a positive correlation between gamma band oscillations and psychoacoustic tinnitus loudness determined with the reconstructed tinnitus sound, but not with the other psychoacoustic loudness measures that were used. Tinnitus-related distress did also correlate with delta band activity, but at electrode positions different from those associated with tinnitus loudness. Furthermore, highly distressed tinnitus patients exhibited a higher level of theta band activity. Moreover, mean hearing loss between 0.125 kHz and 16 kHz was associated with a decrease in gamma activity, whereas minimum masking levels correlated positively with delta band power. In contrast, psychological comorbidities did not express significant correlations with oscillatory brain activity. Conclusion Different clinically relevant tinnitus characteristics show distinctive associations with spontaneous brain oscillatory power. Results support hypothesis (1), but exclusively for the tinnitus loudness derived from matching to the reconstructed tinnitus sound. This suggests to preferably use the reconstructed tinnitus spectrum to determine psychoacoustic tinnitus loudness. Results also support hypothesis (2). Moreover, hearing loss and minimum masking level correlate with oscillatory power in distinctive frequency bands. The lack of an association between psychological comorbidities and oscillatory power may be attributed to the overall low level of mental health problems in the present sample. PMID:23326394

  6. Regional brain activity during early visual perception in unaffected siblings of schizophrenia patients.

    PubMed

    Lee, Junghee; Cohen, Mark S; Engel, Stephen A; Glahn, David; Nuechterlein, Keith H; Wynn, Jonathan K; Green, Michael F

    2010-07-01

    Visual masking paradigms assess the early part of visual information processing, which may reflect vulnerability measures for schizophrenia. We examined the neural substrates of visual backward performance in unaffected sibling of schizophrenia patients using functional magnetic resonance imaging (fMRI). Twenty-one unaffected siblings of schizophrenia patients and 19 healthy controls performed a backward masking task and three functional localizer tasks to identify three visual processing regions of interest (ROI): lateral occipital complex (LO), the motion-sensitive area, and retinotopic areas. In the masking task, we systematically manipulated stimulus onset asynchronies (SOAs). We analyzed fMRI data in two complementary ways: 1) an ROI approach for three visual areas, and 2) a whole-brain analysis. The groups did not differ in behavioral performance. For ROI analysis, both groups increased activation as SOAs increased in LO. Groups did not differ in activation levels of the three ROIs. For whole-brain analysis, controls increased activation as a function of SOAs, compared with siblings in several regions (i.e., anterior cingulate cortex, posterior cingulate cortex, inferior prefrontal cortex, inferior parietal lobule). The study found: 1) area LO showed sensitivity to the masking effect in both groups; 2) siblings did not differ from controls in activation of LO; and 3) groups differed significantly in several brain regions outside visual processing areas that have been related to attentional or re-entrant processes. These findings suggest that LO dysfunction may be a disease indicator rather than a risk indicator for schizophrenia. Copyright 2010 Society of Biological Psychiatry. Published by Elsevier Inc. All rights reserved.

  7. Effect of SPM-based cleaning POR on EUV mask performance

    NASA Astrophysics Data System (ADS)

    Choi, Jaehyuck; Lee, Han-shin; Yoon, Jinsang; Shimomura, Takeya; Friz, Alex; Montgomery, Cecilia; Ma, Andy; Goodwin, Frank; Kang, Daehyuk; Chung, Paul; Shin, Inkyun; Cho, H.

    2011-11-01

    EUV masks include many different layers of various materials rarely used in optical masks, and each layer of material has a particular role in enhancing the performance of EUV lithography. Therefore, it is crucial to understand how the mask quality and patterning performance can change during mask fabrication, EUV exposure, maintenance cleaning, shipping, or storage. The fact that a pellicle is not used to protect the mask surface in EUV lithography suggests that EUV masks may have to undergo more cleaning cycles during their lifetime. More frequent cleaning, combined with the adoption of new materials for EUV masks, necessitates that mask manufacturers closely examine the performance change of EUV masks during cleaning process. We have investigated EUV mask quality and patterning performance during 30 cycles of Samsung's EUV mask SPM-based cleaning and 20 cycles of SEMATECH ADT exposure. We have observed that the quality and patterning performance of EUV masks does not significantly change during these processes except mask pattern CD change. To resolve this issue, we have developed an acid-free cleaning POR and substantially improved EUV mask film loss compared to the SPM-based cleaning POR.

  8. Comparison of face masks in the bag-mask ventilation of a manikin.

    PubMed

    Redfern, D; Rassam, S; Stacey, M R; Mecklenburgh, J S

    2006-02-01

    We conducted a study investigating the effectiveness of four face mask designs in the bag-mask ventilation of a special manikin adapted to simulate a difficult airway. Forty-eight anaesthetists volunteered to bag-mask ventilate the manikin for 3 min with four different face masks. The primary outcome of the study was to calculate mean percentage leak from the face masks over 3 min. Anaesthetists were also asked to rate the face masks using a visual analogue score. The single-use scented intersurgical face mask had the lowest mean leak (20%). This was significantly lower than the mean leak from the single-use, cushioned 7,000 series Air Safety Ltd. face mask (24%) and the reusable silicone Laerdal face mask (27%) but not significantly lower than the mean leak from the reusable anatomical intersurgical face mask (23%). There was a large variation in both performance and satisfaction between anaesthetists with each design. This highlights the importance of having a variety of face masks available for emergency use.

  9. Two Words, One Meaning: Evidence of Automatic Co-Activation of Translation Equivalents

    PubMed Central

    Dimitropoulou, Maria; Duñabeitia, Jon Andoni; Carreiras, Manuel

    2011-01-01

    Research on the processing of translations offers important insights on how bilinguals negotiate the representation of words from two languages in one mind and one brain. Evidence so far has shown that translation equivalents effectively activate each other as well as their shared concept even when translations lack of any formal overlap (i.e., non-cognates) and even when one of them is presented subliminally, namely under masked priming conditions. In the lexical decision studies testing masked translation priming effects with unbalanced bilinguals a remarkably stable pattern emerges: larger effects in the dominant (L1) to the non-dominant (L2) translation direction, than vice versa. Interestingly, this asymmetry vanishes when simultaneous and balanced bilinguals are tested, suggesting that the linguistic profile of the bilinguals could be determining the pattern of cross-language lexico-semantic activation across the L2 learning trajectory. The present study aims to detect whether L2 proficiency is the critical variable rendering the otherwise asymmetric cross-language activation of translations obtained in the lexical decision task into symmetric. Non-cognate masked translation priming effects were examined with three groups of Greek (L1)–English (L2) unbalanced bilinguals, differing exclusively at their level of L2 proficiency. Although increased L2 proficiency led to improved overall L2 performance, masked translation priming effects were virtually identical across the three groups, yielding in all cases significant but asymmetric effects (i.e., larger effects in the L1 → L2 than in the L2 → L1 translation direction). These findings show that proficiency does not modulate masked translation priming effects at intermediate levels, and that a native-like level of L2 proficiency is needed for symmetric effects to emerge. They furthermore, pose important constraints on the operation of the mechanisms underlying the development of cross-language lexico-semantic links. PMID:21886634

  10. Nasal versus oronasal continuous positive airway pressure masks for obstructive sleep apnea: a pilot investigation of pressure requirement, residual disease, and leak.

    PubMed

    Bakker, Jessie P; Neill, Alister M; Campbell, Angela J

    2012-09-01

    This single-blinded, randomized, controlled pilot study aimed to investigate whether there is a difference between nasal and oronasal masks in therapeutic continuous positive airway pressure (CPAP) requirement, residual disease, or leak when treating obstructive sleep apnea (OSA) and if differences were related to measures of upper airway size. Patients with severe OSA currently using CPAP at ≥4 h/night with a nasal mask were examined (including Mallampati scale, incisal relationship, and mandibular protrusion) and then randomized to receive auto-positive airway pressure (PAP) or fixed CPAP at a manually titrated pressure for 1 week each at home, with immediate crossover. Within each week, a nasal mask and two oronasal masks were to be used for two or three nights each in random order. Data were downloaded from the device. Twelve patients completed the trial (mean ± SD AHI 59.8 ± 28.6 events/h; CPAP 11.1 ± 3.2 cmH(2)O; BMI 37.7 ± 5.0 kg/m(2)). During auto-PAP, the median 95th percentile pressure delivered with all masks was within 0.5 cmH(2)O (p > 0.05). During CPAP, median residual AHI was 0.61 (IQR = 1.18) for the nasal mask, 1.70 (IQR = 4.04) for oronasal mask 1, and 2.48 (IQR = 3.74) for oronasal mask 2 (p = 0.03). The 95th percentile leak was lowest with the nasal mask during both CPAP and auto-PAP (both p < 0.01). Differences in pressure or residual disease were not related to measures of upper airway shape or body habitus. In obese OSA patients changing from a nasal to oronasal mask increased leak and residual AHI but did not affect the therapeutic pressure requirement. The findings of the current study highlight mask leak as the major difficulty in the use of oronasal masks.

  11. Fast prototyping of high-aspect ratio, high-resolution x-ray masks by gas-assisted focused ion beam

    NASA Technical Reports Server (NTRS)

    Hartley, F.; Malek, C.; Neogi, J.

    2001-01-01

    The capacity of chemically-assisted focused ion beam (fib) etching systems to undertake direct and highly anisotropic erosion of thin and thick gold (or other high atomic number [Z])coatings on x-ray mask membranes/substrates provides new levels of precision, flexibility, simplification and rapidity in the manufacture of mask absorber patterns, allowing the fast prototyping of high aspect ratio, high-resolution masks for deep x-ray lithography.

  12. Orion Emergency Mask Approach

    NASA Technical Reports Server (NTRS)

    Tuan, George C.; Graf, John C.

    2008-01-01

    Emergency mask approach on Orion poses a challenge to the traditional Shuttle or Station approaches. Currently, in the case of a fire or toxic spill event, the crew utilizes open loop oxygen masks that provide the crew with oxygen to breath, but also dumps the exhaled oxygen into the cabin. For Orion, with a small cabin volume, the extra oxygen will exceed the flammability limit within a short period of time, unless a nitrogen purge is also provided. Another approach to a fire or toxic spill event is the use of a filtering emergency masks. These masks utilize some form of chemical beds to scrub the air clean of toxic providing the crew safe breathing air for a period without elevating the oxygen level in the cabin. Using the masks and a form of smoke-eater filter, it may be possible to clean the cabin completely or to a level for safe transition to a space suit to perform a cabin purge. Issues with filters in the past have been the reaction temperature and high breathing resistance. Development in a new form of chemical filters has shown promise to make the filtering approach feasible.

  13. Orion Emergency Mask Approach

    NASA Technical Reports Server (NTRS)

    Tuan, George C.; Graf, John C.

    2009-01-01

    Emergency mask approach on Orion poses a challenge to the traditional Shuttle or Station approaches. Currently, in the case of a fire or toxic spill event, the crew utilizes open loop oxygen masks that provide the crew with oxygen to breath, but also dumps the exhaled oxygen into the cabin. For Orion, with a small cabin volume, the extra oxygen will exceed the flammability limit within a short period of time, unless a nitrogen purge is also provided. Another approach to a fire or toxic spill event is the use of a filtering emergency masks. These masks utilize some form of chemical beds to scrub the air clean of toxic providing the crew safe breathing air for a period without elevating the oxygen level in the cabin. Using the masks and a form of smoke-eater filter, it may be possible to clean the cabin completely or to a level for safe transition to a space suit to perform a cabin purge. Issues with filters in the past have been the reaction time, breakthroughs, and high breathing resistance. Development in a new form of chemical filters has shown promise to make the filtering approach feasible.

  14. [A comparison of various supraglottic airway devices for fiberoptical guided tracheal intubation].

    PubMed

    Metterlein, Thomas; Dintenfelder, Anna; Plank, Christoph; Graf, Bernhard; Roth, Gabriel

    Fiberoptical assisted intubation via placed supraglottic airway devices has been described as safe and easy procedure to manage difficult airways. However visualization of the glottis aperture is essential for fiberoptical assisted intubation. Various different supraglottic airway devices are commercially available and might offer different conditions for fiberoptical assisted intubation. The aim of this study was to compare the best obtainable view of the glottic aperture using different supraglottic airway devices. With approval of the local ethics committee 52 adult patients undergoing elective anesthesia were randomly assigned to a supraglottic airway device (Laryngeal Tube, Laryngeal Mask Airway I-Gel, Laryngeal Mask Airway Unique, Laryngeal Mask Airway Supreme, Laryngeal Mask Airway Aura-once). After standardized induction of anaesthesia the supraglottic airway device was placed according to the manufacturers recommendations. After successful ventilation the position of the supraglottic airway device in regard to the glottic opening was examined with a flexible fiberscope. A fully or partially visible glottic aperture was considered as suitable for fiberoptical assisted intubation. Suitability for fiberoptical assisted intubation was compared between the groups (H-test, U-test; p<0.05). Demographic data was not different between the groups. Placement of the supraglottic airway device and adequate ventilation was successful in all attempts. Glottic view suitable for fiberoptical assisted intubation differed between the devices ranging from 40% for the laringeal tube (LT), 66% for the laryngeal mask airway Supreme, 70% for the Laryngeal Mask Airway I-Gel and 90% for both the Laryngeal Mask Airway Unique and the Laryngeal Mask Airway Aura-once. None of the used supraglottic airway devices offered a full or partial glottic view in all cases. However the Laryngeal Mask Airway Unique and the Laryngeal Mask Airway Aura-once seem to be more suitable for fiberoptical assisted intubation compared to other devices. Copyright © 2016 Sociedade Brasileira de Anestesiologia. Publicado por Elsevier Editora Ltda. All rights reserved.

  15. A comparison of various supraglottic airway devices for fiberoptical guided tracheal intubation.

    PubMed

    Metterlein, Thomas; Dintenfelder, Anna; Plank, Christoph; Graf, Bernhard; Roth, Gabriel

    Fiberoptical assisted intubation via placed supraglottic airway devices has been described as safe and easy procedure to manage difficult airways. However visualization of the glottis aperture is essential for fiberoptical assisted intubation. Various different supraglottic airway devices are commercially available and might offer different conditions for fiberoptical assisted intubation. The aim of this study was to compare the best obtainable view of the glottic aperture using different supraglottic airway devices. With approval of the local ethics committee 52 adult patients undergoing elective anesthesia were randomly assigned to a supraglottic airway device (Laryngeal Tube, Laryngeal Mask Airway I-Gel, Laryngeal Mask Airway Unique, Laryngeal Mask Airway Supreme, Laryngeal Mask Airway Aura-once). After standardized induction of anesthesia the supraglottic airway device was placed according to the manufacturers recommendations. After successful ventilation the position of the supraglottic airway device in regard to the glottic opening was examined with a flexible fiberscope. A fully or partially visible glottic aperture was considered as suitable for fiberoptical assisted intubation. Suitability for fiberoptical assisted intubation was compared between the groups (H-test, U-test; p<0.05). Demographic data was not different between the groups. Placement of the supraglottic airway device and adequate ventilation was successful in all attempts. Glottic view suitable for fiberoptical assisted intubation differed between the devices ranging from 40% for the laringeal tube (LT), 66% for the laryngeal mask airway Supreme, 70% for the Laryngeal Mask Airway I-Gel and 90% for both the Laryngeal Mask Airway Unique and the Laryngeal Mask Airway Aura-once. None of the used supraglottic airway devices offered a full or partial glottic view in all cases. However the Laryngeal Mask Airway Unique and the Laryngeal Mask Airway Aura-once seem to be more suitable for fiberoptical assisted intubation compared to other devices. Copyright © 2016 Sociedade Brasileira de Anestesiologia. Published by Elsevier Editora Ltda. All rights reserved.

  16. Phase effects in masking by harmonic complexes: speech recognition.

    PubMed

    Deroche, Mickael L D; Culling, John F; Chatterjee, Monita

    2013-12-01

    Harmonic complexes that generate highly modulated temporal envelopes on the basilar membrane (BM) mask a tone less effectively than complexes that generate relatively flat temporal envelopes, because the non-linear active gain of the BM selectively amplifies a low-level tone in the dips of a modulated masker envelope. The present study examines a similar effect in speech recognition. Speech reception thresholds (SRTs) were measured for a voice masked by harmonic complexes with partials in sine phase (SP) or in random phase (RP). The masker's fundamental frequency (F0) was 50, 100 or 200 Hz. SRTs were considerably lower for SP than for RP maskers at 50-Hz F0, but the two converged at 100-Hz F0, while at 200-Hz F0, SRTs were a little higher for SP than RP maskers. The results were similar whether the target voice was male or female and whether the masker's spectral profile was flat or speech-shaped. Although listening in the masker dips has been shown to play a large role for artificial stimuli such as Schroeder-phase complexes at high levels, it contributes weakly to speech recognition in the presence of harmonic maskers with different crest factors at more moderate sound levels (65 dB SPL). Copyright © 2013 Elsevier B.V. All rights reserved.

  17. ILT based defect simulation of inspection images accurately predicts mask defect printability on wafer

    NASA Astrophysics Data System (ADS)

    Deep, Prakash; Paninjath, Sankaranarayanan; Pereira, Mark; Buck, Peter

    2016-05-01

    At advanced technology nodes mask complexity has been increased because of large-scale use of resolution enhancement technologies (RET) which includes Optical Proximity Correction (OPC), Inverse Lithography Technology (ILT) and Source Mask Optimization (SMO). The number of defects detected during inspection of such mask increased drastically and differentiation of critical and non-critical defects are more challenging, complex and time consuming. Because of significant defectivity of EUVL masks and non-availability of actinic inspection, it is important and also challenging to predict the criticality of defects for printability on wafer. This is one of the significant barriers for the adoption of EUVL for semiconductor manufacturing. Techniques to decide criticality of defects from images captured using non actinic inspection images is desired till actinic inspection is not available. High resolution inspection of photomask images detects many defects which are used for process and mask qualification. Repairing all defects is not practical and probably not required, however it's imperative to know which defects are severe enough to impact wafer before repair. Additionally, wafer printability check is always desired after repairing a defect. AIMSTM review is the industry standard for this, however doing AIMSTM review for all defects is expensive and very time consuming. Fast, accurate and an economical mechanism is desired which can predict defect printability on wafer accurately and quickly from images captured using high resolution inspection machine. Predicting defect printability from such images is challenging due to the fact that the high resolution images do not correlate with actual mask contours. The challenge is increased due to use of different optical condition during inspection other than actual scanner condition, and defects found in such images do not have correlation with actual impact on wafer. Our automated defect simulation tool predicts printability of defects at wafer level and automates the process of defect dispositioning from images captured using high resolution inspection machine. It first eliminates false defects due to registration, focus errors, image capture errors and random noise caused during inspection. For the remaining real defects, actual mask-like contours are generated using the Calibre® ILT solution [1][2], which is enhanced to predict the actual mask contours from high resolution defect images. It enables accurate prediction of defect contours, which is not possible from images captured using inspection machine because some information is already lost due to optical effects. Calibre's simulation engine is used to generate images at wafer level using scanner optical conditions and mask-like contours as input. The tool then analyses simulated images and predicts defect printability. It automatically calculates maximum CD variation and decides which defects are severe to affect patterns on wafer. In this paper, we assess the printability of defects for the mask of advanced technology nodes. In particular, we will compare the recovered mask contours with contours extracted from SEM image of the mask and compare simulation results with AIMSTM for a variety of defects and patterns. The results of printability assessment and the accuracy of comparison are presented in this paper. We also suggest how this method can be extended to predict printability of defects identified on EUV photomasks.

  18. The color masking ability of a zirconia ceramic on the substrates with different values.

    PubMed

    Tabatabaian, Farhad; Javadi Sharif, Mahdiye; Massoumi, Farhood; Namdari, Mahshid

    2017-01-01

    Background. The color masking ability of a restoration plays a significant role in coveringa discolored substructure; however, this optical property of zirconia ceramics has not been clearly determined yet. The aim of this in vitro study was to evaluate the color masking ability of a zirconia ceramic on substrates with different values. Methods. Ten zirconia disk specimens,0.5 mm in thickness and 10 mm in diameter, were fabricated by a CAD/CAM system. Four substrates with different values were prepared, including: white (control), light grey, dark grey, and black. The disk specimens were placed over the substratesfor spectrophotometric measurements. A spectrophotometer measured the L * , a * , and b * color attributes of the specimens. Additionally, ΔE values were calculated to determine the color differences between each group and the control,and were then compared with the perceptional threshold of ΔE=2.6. Repeated-measures ANOVA, Bonferroni, and one-sample t-test were used to analyze data. All the tests were carried out at 0.05 level of significance. Results. The means and standard deviations of ΔE values for the three groups of light grey, dark grey and black were 9.94±2.11, 10.40±2.09, and 13.34±1.77 units, respectively.Significant differences were detected between the groups in the ΔE values (P<0.0001).The ΔE values in all the groups were more than the predetermined perceptional threshold(ΔE>2.6) (P<0.0001). Conclusion. Within the limitations of this study, it was concluded that the tested zirconia ceramic did not exhibit sufficient color masking ability to hide the grey and black substrates.

  19. Penetration of diesel exhaust particles through commercially available dust half masks.

    PubMed

    Penconek, Agata; Drążyk, Paulina; Moskal, Arkadiusz

    2013-04-01

    Half masks are certified by the competent, national institutions--National Institute for Occupational Safety and Health (NIOSH) in the USA and the respective European national institutions applying common European regulations. However, certification testing is conducted with particles of NaCl, paraffin oil, or dioctyl phthalate (DOP) and at the constant flow rate, whereas particles commonly found in workplaces may differ in size, shape, and morphology from these particles. Therefore, the aim of this study was to investigate filtration efficiency of commercially available filtering facepiece half masks under the condition of exposure to diesel fumes. In this study, we focused on the particulate phase [diesel exhaust particles (DEP)] of three (petroleum diesel, ecodiesel, and biodiesel) diesel fuel combustion types. Two types of European standard-certified half masks, FFP2 and FFP - Filtering Facepiece, and three types of popular diesel fuels were tested. The study showed that the filtration efficiencies for each examined half mask and for each of diesel exhaust fumes were lower than the minimum filtration efficiency required for the standard test aerosols by the European standards. For FFP2 and FFP3 particulate half masks, standard minimum filtration efficiency is 94 and 99%, respectively, whereas 84-89% of mass of DEP from various fuels were filtered by the tested FFP2 and only 75-86% by the FFP3. The study indicated that DEP is more penetrating for these filters than the standard salt or paraffin oil test aerosols. The study also showed that the most penetrating DEP are probably in the 30- to 300-nm size range, regardless of the fuel type and the half-mask model. Finally, the pressure drops across both half masks during the 80-min tests remained below an acceptable maximum of breathing resistance-regardless of the fuel types. The respiratory system, during 40-min test exposures, may be exposed to 12-16mg of DEP if a FFP2 or FFP3 particulate half mask is used. To conclude, commercially available half masks may not ensure a sufficient level of protection of the respiratory tract against diesel exhaust fumes.

  20. Not All Skilled Readers Have Cracked the Code: Individual Differences in Masked Form Priming

    ERIC Educational Resources Information Center

    Andrews, Sally; Lo, Steson

    2012-01-01

    This experiment investigated whether individual differences in written language proficiency among university students predict the early stages of lexical retrieval tapped by the masked form priming lexical decision task. To separate the contributions of sublexical facilitation and lexical competition to masked form priming, the effects of prime…

  1. Visual Masking in Schizophrenia: Overview and Theoretical Implications

    PubMed Central

    Green, Michael F.; Lee, Junghee; Wynn, Jonathan K.; Mathis, Kristopher I.

    2011-01-01

    Visual masking provides several key advantages for exploring the earliest stages of visual processing in schizophrenia: it allows for control over timing at the millisecond level, there are several well-supported theories of the underlying neurobiology of visual masking, and it is amenable to examination by electroencephalogram (EEG) and functional magnetic resonance imaging (fMRI). In this paper, we provide an overview of the visual masking impairment schizophrenia, including the relevant theoretical mechanisms for masking impairment. We will discuss its relationship to clinical symptoms, antipsychotic medications, diagnostic specificity, and presence in at-risk populations. As part of this overview, we will cover the neural correlates of visual masking based on recent findings from EEG and fMRI. Finally, we will suggest a possible mechanism that could explain the patterns of masking findings and other visual processing findings in schizophrenia. PMID:21606322

  2. Aided speech recognition in single-talker competition by elderly hearing-impaired listeners

    NASA Astrophysics Data System (ADS)

    Coughlin, Maureen; Humes, Larry

    2004-05-01

    This study examined the speech-identification performance in one-talker interference conditions that increased in complexity while audibility was ensured over a wide bandwidth (200-4000 Hz). Factorial combinations of three independent variables were used to vary the amount of informational masking. These variables were: (1) competition playback direction (forward or reverse); (2) gender match between target and competition talkers (same or different); and (3) target talker uncertainty (one of three possible talkers from trial to trial). Four groups of listeners, two elderly hearing-impaired groups differing in age (65-74 and 75-84 years) and two young normal-hearing groups, were tested. One of the groups of young normal-hearing listeners was tested under acoustically equivalent test conditions and one was tested under perceptually equivalent test conditions. The effect of each independent variable on speech-identification performance and informational masking was generally consistent with expectations. Group differences in the observed informational masking were most pronounced for the oldest group of hearing-impaired listeners. The eight measures of speech-identification performance were found to be strongly correlated with one another, and individual differences in speech understanding performance among the elderly were found to be associated with age and level of education. [Work supported, in part, by NIA.

  3. Shadows Alter Facial Expressions of Noh Masks

    PubMed Central

    Kawai, Nobuyuki; Miyata, Hiromitsu; Nishimura, Ritsuko; Okanoya, Kazuo

    2013-01-01

    Background A Noh mask, worn by expert actors during performance on the Japanese traditional Noh drama, conveys various emotional expressions despite its fixed physical properties. How does the mask change its expressions? Shadows change subtly during the actual Noh drama, which plays a key role in creating elusive artistic enchantment. We here describe evidence from two experiments regarding how attached shadows of the Noh masks influence the observers’ recognition of the emotional expressions. Methodology/Principal Findings In Experiment 1, neutral-faced Noh masks having the attached shadows of the happy/sad masks were recognized as bearing happy/sad expressions, respectively. This was true for all four types of masks each of which represented a character differing in sex and age, even though the original characteristics of the masks also greatly influenced the evaluation of emotions. Experiment 2 further revealed that frontal Noh mask images having shadows of upward/downward tilted masks were evaluated as sad/happy, respectively. This was consistent with outcomes from preceding studies using actually tilted Noh mask images. Conclusions/Significance Results from the two experiments concur that purely manipulating attached shadows of the different types of Noh masks significantly alters the emotion recognition. These findings go in line with the mysterious facial expressions observed in Western paintings, such as the elusive qualities of Mona Lisa’s smile. They also agree with the aesthetic principle of Japanese traditional art “yugen (profound grace and subtlety)”, which highly appreciates subtle emotional expressions in the darkness. PMID:23940748

  4. Influence of total face, facial and nasal masks on short-term adverse effects during noninvasive ventilation.

    PubMed

    Holanda, Marcelo Alcantara; Reis, Ricardo Coelho; Winkeler, Georgia Freire Paiva; Fortaleza, Simone Castelo Branco; Lima, José Wellington de Oliveira; Pereira, Eanes Delgado Barros

    2009-02-01

    Failure of noninvasive ventilation (NIV) has been associated with short-term adverse effects related to the use of masks. The aim of this study was to compare the incidence, type and intensity of adverse effects, as well as the comfort, of total face masks (TFMs), facial masks (FMs) and nasal masks (NMs) during NIV. This was a randomized crossover trial involving 24 healthy volunteers submitted to six sessions of NIV in bilevel positive airway pressure mode using the TFM, FM and NM masks at low and moderate-to-high pressure levels. A written questionnaire was applied in order to evaluate eleven specific adverse effects related to the use of the masks. Comfort was assessed using a visual analog scale. The CO2 exhaled into the ventilator circuit was measured between the mask and the exhalation port. The performance of the TFM was similar to that of the NM and FM in terms of comfort scores. Higher pressure levels reduced comfort and increased adverse effects, regardless of the mask type. When the TFM was used, there were fewer air leaks and less pain at the nose bridge, although there was greater oronasal dryness and claustrophobia. Air leaks were most pronounced when the FM was used. The partial pressure of exhaled CO2 entering the ventilator circuit was zero for the TFM. The short-term adverse effects caused by NIV interfaces are related to mask type and pressure settings. The TFM is a reliable alternative to the NM and FM. Rebreathing of CO2 from the circuit is less likely to occur when a TFM is used.

  5. Rigorous diffraction analysis using geometrical theory of diffraction for future mask technology

    NASA Astrophysics Data System (ADS)

    Chua, Gek S.; Tay, Cho J.; Quan, Chenggen; Lin, Qunying

    2004-05-01

    Advanced lithographic techniques such as phase shift masks (PSM) and optical proximity correction (OPC) result in a more complex mask design and technology. In contrast to the binary masks, which have only transparent and nontransparent regions, phase shift masks also take into consideration transparent features with a different optical thickness and a modified phase of the transmitted light. PSM are well-known to show prominent diffraction effects, which cannot be described by the assumption of an infinitely thin mask (Kirchhoff approach) that is used in many commercial photolithography simulators. A correct prediction of sidelobe printability, process windows and linearity of OPC masks require the application of rigorous diffraction theory. The problem of aerial image intensity imbalance through focus with alternating Phase Shift Masks (altPSMs) is performed and compared between a time-domain finite-difference (TDFD) algorithm (TEMPEST) and Geometrical theory of diffraction (GTD). Using GTD, with the solution to the canonical problems, we obtained a relationship between the edge on the mask and the disturbance in image space. The main interest is to develop useful formulations that can be readily applied to solve rigorous diffraction for future mask technology. Analysis of rigorous diffraction effects for altPSMs using GTD approach will be discussed.

  6. Cross sectional: perception of children from public and private schools regarding the esthetic impact of different types of face masks.

    PubMed

    Pithon, Matheus Melo; Ferraz, Caio Sousa; de Oliveira, Gabriel Couto; Dos Santos, Adrielle Mangabeira; Couto, Felipe Santos; da Silva Coqueiro, Raildo; Dos Santos, Rogério Lacerda

    2013-01-01

    The purpose was to evaluate the esthetic perception among children from public and private schools regarding the use of different types of face masks. Six different types of orthopedic face masks made from images of the same patient were evaluated. Initially, the images were standardized with the help of Adobe Photoshop software. The variable considered was type of mask: (A) Delaire with facebow; (B) Petit; (C) Delaire; (D)Turley; (E) Hickham; and (F) Sky Hook. The images were printed on photographic paper and incorporated into a specific personalized questionnaire that was distributed to 7- to 10-year-olds attending public and private schools (n=120). The data obtained were compared via chi-square, Fisher's exact tests, Mann-Whitney and Spearman's tests. The proportion of participants who chose image A as the best was significantly higher (P<.05) compared to the other masks. Images B and F were chosen as the worst, without a significant difference between them (P>.05). The mean scores between groups were not significantly correlated between private vs public schoolchildren (r=0.32) and between boys and girls (r=0.41). Delaire face mask with facebow was chosen as the most attractive, and the Petit and Sky Hook face masks were voted the least attractive.

  7. Undersampling strategies for compressed sensing accelerated MR spectroscopic imaging

    NASA Astrophysics Data System (ADS)

    Vidya Shankar, Rohini; Hu, Houchun Harry; Bikkamane Jayadev, Nutandev; Chang, John C.; Kodibagkar, Vikram D.

    2017-03-01

    Compressed sensing (CS) can accelerate magnetic resonance spectroscopic imaging (MRSI), facilitating its widespread clinical integration. The objective of this study was to assess the effect of different undersampling strategy on CS-MRSI reconstruction quality. Phantom data were acquired on a Philips 3 T Ingenia scanner. Four types of undersampling masks, corresponding to each strategy, namely, low resolution, variable density, iterative design, and a priori were simulated in Matlab and retrospectively applied to the test 1X MRSI data to generate undersampled datasets corresponding to the 2X - 5X, and 7X accelerations for each type of mask. Reconstruction parameters were kept the same in each case(all masks and accelerations) to ensure that any resulting differences can be attributed to the type of mask being employed. The reconstructed datasets from each mask were statistically compared with the reference 1X, and assessed using metrics like the root mean square error and metabolite ratios. Simulation results indicate that both the a priori and variable density undersampling masks maintain high fidelity with the 1X up to five-fold acceleration. The low resolution mask based reconstructions showed statistically significant differences from the 1X with the reconstruction failing at 3X, while the iterative design reconstructions maintained fidelity with the 1X till 4X acceleration. In summary, a pilot study was conducted to identify an optimal sampling mask in CS-MRSI. Simulation results demonstrate that the a priori and variable density masks can provide statistically similar results to the fully sampled reference. Future work would involve implementing these two masks prospectively on a clinical scanner.

  8. Optical DC overlay measurement in the 2nd level process of 65 nm alternating phase shift mask

    NASA Astrophysics Data System (ADS)

    Ma, Jian; Han, Ke; Lee, Kyung; Korobko, Yulia; Silva, Mary; Chavez, Joas; Irvine, Brian; Henrichs, Sven; Chakravorty, Kishore; Olshausen, Robert; Chandramouli, Mahesh; Mammen, Bobby; Padmanaban, Ramaswamy

    2005-11-01

    Alternating phase shift mask (APSM) techniques help bridge the significant gap between the lithography wavelength and the patterning of minimum features, specifically, the poly line of 35 nm gate length (1x) in Intel's 65 nm technology. One of key steps in making APSM mask is to pattern to within the design tolerances the 2nd level resist so that the zero-phase apertures will be protected by the resist and the pi-phase apertures will be wide open for quartz etch. The ability to align the 2nd level to the 1st level binary pattern, i.e. the 2nd level overlay capability is very important, so is the capability of measuring the overlay accurately. Poor overlay could cause so-called the encroachment after quartz etch, producing undesired quartz bumps in the pi-apertures or quartz pits in the zero-apertures. In this paper, a simple, low-cost optical setup for the 2nd level DC (develop check) overlay measurements in the high volume manufacturing (HVM) of APSM masks is presented. By removing systematic errors in overlay associated with TIS and MIS (tool-induced shift and Mask-process induced shift), it is shown that this setup is capable of supporting the measurement of DC overlay with a tolerance as small as +/- 25 nm. The outstanding issues, such as DC overlay error component analysis, DC - FC (final check) overlay correlation and the overlay linearity (periphery vs. indie), are discussed.

  9. Orientation tuning of contrast masking caused by motion streaks.

    PubMed

    Apthorp, Deborah; Cass, John; Alais, David

    2010-08-01

    We investigated whether the oriented trails of blur left by fast-moving dots (i.e., "motion streaks") effectively mask grating targets. Using a classic overlay masking paradigm, we varied mask contrast and target orientation to reveal underlying tuning. Fast-moving Gaussian blob arrays elevated thresholds for detection of static gratings, both monoptically and dichoptically. Monoptic masking at high mask (i.e., streak) contrasts is tuned for orientation and exhibits a similar bandwidth to masking functions obtained with grating stimuli (∼30 degrees). Dichoptic masking fails to show reliable orientation-tuned masking, but dichoptic masks at very low contrast produce a narrowly tuned facilitation (∼17 degrees). For iso-oriented streak masks and grating targets, we also explored masking as a function of mask contrast. Interestingly, dichoptic masking shows a classic "dipper"-like TVC function, whereas monoptic masking shows no dip and a steeper "handle". There is a very strong unoriented component to the masking, which we attribute to transiently biased temporal frequency masking. Fourier analysis of "motion streak" images shows interesting differences between dichoptic and monoptic functions and the information in the stimulus. Our data add weight to the growing body of evidence that the oriented blur of motion streaks contributes to the processing of fast motion signals.

  10. Mask ventilation with two different face masks in the delivery room for preterm infants: a randomized controlled trial.

    PubMed

    Cheung, D; Mian, Q; Cheung, P-Y; O'Reilly, M; Aziz, K; van Os, S; Pichler, G; Schmölzer, G M

    2015-07-01

    If an infant fails to initiate spontaneous breathing after birth, international guidelines recommend a positive pressure ventilation (PPV). However, PPV by face mask is frequently inadequate because of leak between the face and mask. Despite a variety of available face masks, none have been prospectively compared in a randomized fashion. We aimed to evaluate and compare leak between two commercially available round face masks (Fisher & Paykel (F&P) and Laerdal) in preterm infants <33 weeks gestational age in the delivery room. Infants born at the Royal Alexandra Hospital from April to September 2013 at <33 weeks gestational age who received mask PPV in the delivery room routinely had a flow sensor placed between the mask and T-piece resuscitator. Infants were randomly assigned to receive PPV with either a F&P or Laerdal face mask. All resuscitators were trained in the use of both face masks. We compared mask leak, airway pressures, tidal volume and ventilation rate between the two groups. Fifty-six preterm infants (n=28 in each group) were enrolled; mean±s.d. gestational age 28±3 weeks; birth weight 1210±448 g; and 30 (52%) were male. Apgar scores at 1 and 5 min were 5±3 and 7±2, respectively. Infants randomized to the F&P face mask and Laerdal face mask had similar mask leak (30 (25-38) versus 35 (24-46)%, median (interquartile range), respectively, P=0.40) and tidal volume (7.1 (4.9-8.9) versus 6.6 (5.2-8.9) ml kg(-1), P=0.69) during PPV. There were no significant differences in ventilation rate, inflation time or airway pressures between groups. The use of either face mask during PPV in the delivery room yields similar mask leak in preterm infants <33 weeks gestational age.

  11. Neopuff T-piece resuscitator mask ventilation: Does mask leak vary with different peak inspiratory pressures in a manikin model?

    PubMed

    Maheshwari, Rajesh; Tracy, Mark; Hinder, Murray; Wright, Audrey

    2017-08-01

    The aim of this study was to compare mask leak with three different peak inspiratory pressure (PIP) settings during T-piece resuscitator (TPR; Neopuff) mask ventilation on a neonatal manikin model. Participants were neonatal unit staff members. They were instructed to provide mask ventilation with a TPR with three PIP settings (20, 30, 40 cm H 2 O) chosen in a random order. Each episode was for 2 min with 2-min rest period. Flow rate and positive end-expiratory pressure (PEEP) were kept constant. Airway pressure, inspiratory and expiratory tidal volumes, mask leak, respiratory rate and inspiratory time were recorded. Repeated measures analysis of variance was used for statistical analysis. A total of 12 749 inflations delivered by 40 participants were analysed. There were no statistically significant differences (P > 0.05) in the mask leak with the three PIP settings. No statistically significant differences were seen in respiratory rate and inspiratory time with the three PIP settings. There was a significant rise in PEEP as the PIP increased. Failure to achieve the desired PIP was observed especially at the higher settings. In a neonatal manikin model, the mask leak does not vary as a function of the PIP when the flow rate is constant. With a fixed rate and inspiratory time, there seems to be a rise in PEEP with increasing PIP. © 2017 Paediatrics and Child Health Division (The Royal Australasian College of Physicians).

  12. My Other Half Manifested in Mask-Making

    ERIC Educational Resources Information Center

    Abel, Xanthippi

    2010-01-01

    Every fall season, each grade level of Rowland Hall St. Mark's Lower School in Salt Lake City, Utah, completes a mask-making project to be featured in a schoolwide parade. This sparked an opportunity to incorporate the fourth-grade unit of realistic and observational drawing with mask making. In this article, the author describes how her students…

  13. Improved techniques reduce face mask leak during simulated neonatal resuscitation: study 2.

    PubMed

    Wood, Fiona E; Morley, Colin J; Dawson, Jennifer A; Kamlin, C Omar F; Owen, Louise S; Donath, Susan; Davis, Peter G

    2008-05-01

    Techniques of positioning and holding neonatal face masks vary. Studies have shown that leak at the face mask is common and often substantial irrespective of operator experience. (1) To identify a technique for face mask placement and hold which will minimise mask leak. (2) To investigate the effect of written instruction and demonstration of the identified technique on mask leak for two round face masks. Three experienced neonatologists compared methods of placing and holding face masks to minimise the leak for Fisher & Paykel 60 mm and Laerdal size 0/1 masks. 50 clinical staff gave positive pressure ventilation to a modified manikin designed to measure leak at the face mask. They were provided with written instructions on how to position and hold each mask and then received a demonstration. Face mask leak was measured after each teaching intervention. A technique of positioning and holding the face masks was identified which minimised leak. The mean (SD) mask leaks before instruction, after instruction and after demonstration were 55% (31), 49% (30), 33% (26) for the Laerdal mask and 57% (25), 47% (28), 32% (30) for the Fisher & Paykel mask. There was no significant difference in mask leak between the two masks. Written instruction alone reduced leak by 8.8% (CI 1.4% to 16.2%) for either mask; when combined with a demonstration mask leak was reduced by 24.1% (CI 16.4% to 31.8%). Written instruction and demonstration of the identified optimal technique resulted in significantly reduced face mask leak.

  14. Exposure to noise during continuous positive airway pressure: influence of interfaces and delivery systems.

    PubMed

    Cavaliere, F; Conti, G; Costa, R; Spinazzola, G; Proietti, R; Sciuto, A; Masieri, S

    2008-01-01

    We measured noise intensity and perceived noisiness during continuous positive airway pressure (CPAP) performed with two interfaces (face-mask, helmet) and four delivery systems. Eight healthy volunteers received CPAP in random order with: two systems provided with a flow generator using the Venturi effect and a mechanical expiratory valve (A: Venturi, Starmed; B: Whisperflow-2, Caradyne Ltd); one 'free-flow' system provided with high flow O(2) and air flowmeters, an inspiratory gas reservoir, and a water valve (C: CF800, Drägerwerk, AG); and a standard mechanical ventilator (Servoventilator 300, Siemens-Elema). Systems A, B, and C were tested with a face-mask and a helmet at a CPAP value of 10 cm H(2)O; the mechanical ventilator was only tested with the face mask. Noise intensity was measured with a sound-level meter. After each test, participants scored noisiness on a visual analog scale (VAS). The noise levels measured ranged from 57+/-11 dBA (mechanical ventilator plus mask) to 93+/-1 and 94+/-2 dBA (systems A and B plus helmet) and were significantly affected by CPAP systems (A and B noisier than C and D) and interfaces (helmet CPAP noisier than mask CPAP). Subjective evaluation showed that systems A and B plus helmet were perceived as noisier than system C plus mask or helmet. Maximum noise levels observed in this study may potentially cause patient discomfort. Less noisy CPAP systems (not using Venturi effect) and interfaces (facial mask better than helmet) should be preferred, particularly for long or nocturnal treatments.

  15. Central masking with bilateral cochlear implants

    PubMed Central

    Lin, Payton; Lu, Thomas; Zeng, Fan-Gang

    2013-01-01

    Across bilateral cochlear implants, contralateral threshold shift has been investigated as a function of electrode difference between the masking and probe electrodes. For contralateral electric masking, maximum threshold elevations occurred when the position of the masker and probe electrode was approximately place-matched across ears. The amount of masking diminished with increasing masker-probe electrode separation. Place-dependent masking occurred in both sequentially implanted ears, and was not affected by the masker intensity or the time delay from the masker onset. When compared to previous contralateral masking results in normal hearing, the similarities between place-dependent central masking patterns suggest comparable mechanisms of overlapping excitation in the central auditory nervous system. PMID:23363113

  16. More Realistic Face Model Surface Improves Relevance of Pediatric In-Vitro Aerosol Studies.

    PubMed

    Amirav, Israel; Halamish, Asaf; Gorenberg, Miguel; Omar, Hamza; Newhouse, Michael T

    2015-01-01

    Various hard face models are commonly used to evaluate the efficiency of aerosol face masks. Softer more realistic "face" surface materials, like skin, deform upon mask application and should provide more relevant in-vitro tests. Studies that simultaneously take into consideration many of the factors characteristic of the in vivo face are lacking. These include airways, various application forces, comparison of various devices, comparison with a hard-surface model and use of a more representative model face based on large numbers of actual faces. To compare mask to "face" seal and aerosol delivery of two pediatric masks using a soft vs. a hard, appropriately representative, pediatric face model under various applied forces. Two identical face models and upper airways replicas were constructed, the only difference being the suppleness and compressibility of the surface layer of the "face." Integrity of the seal and aerosol delivery of two different masks [AeroChamber (AC) and SootherMask (SM)] were compared using a breath simulator, filter collection and realistic applied forces. The soft "face" significantly increased the delivery efficiency and the sealing characteristics of both masks. Aerosol delivery with the soft "face" was significantly greater for the SM compared to the AC (p< 0.01). No statistically significant difference between the two masks was observed with the hard "face." The material and pliability of the model "face" surface has a significant influence on both the seal and delivery efficiency of face masks. This finding should be taken into account during in-vitro aerosol studies.

  17. A conceptual approach to the masking effect of measures of disproportionality.

    PubMed

    Maignen, Francois; Hauben, Manfred; Hung, Eric; Holle, Lionel Van; Dogne, Jean-Michel

    2014-02-01

    Masking is a statistical issue by which true signals of disproportionate reporting are hidden by the presence of other products in the database. Masking is currently not perfectly understood. There is no algorithm to identify the potential masking drugs to remove them for subsequent analyses of disproportionality. The primary objective of our study is to develop a mathematical framework for assessing the extent and impact of the masking effect of measures of disproportionality. We have developed a masking ratio that quantifies the masking effect of a given product. We have conducted a simulation study to validate our algorithm. The masking ratio is a measure of the strength of the masking effect whether the analysis is performed at the report or event level, and the manner in which reports are allocated to cells in the contingency table significantly impact the masking mechanisms. The reports containing both the product of interest and the masking product need to be handled appropriately. The proposed algorithm can use simplified masking provided that underlying assumptions (in particular the size of the database) are verified. For any event, the strongest masking effect is associated with the drug with the highest number of records (reports excluding the product of interest). Our study provides significant insights with practical implications for real-world pharmacovigilance that are supported by both real and simulated data. The public health impact of masking is still unknown. Copyright © 2013 John Wiley & Sons, Ltd.

  18. Selective spatial attention modulates bottom-up informational masking of speech

    PubMed Central

    Carlile, Simon; Corkhill, Caitlin

    2015-01-01

    To hear out a conversation against other talkers listeners overcome energetic and informational masking. Largely attributed to top-down processes, information masking has also been demonstrated using unintelligible speech and amplitude-modulated maskers suggesting bottom-up processes. We examined the role of speech-like amplitude modulations in information masking using a spatial masking release paradigm. Separating a target talker from two masker talkers produced a 20 dB improvement in speech reception threshold; 40% of which was attributed to a release from informational masking. When across frequency temporal modulations in the masker talkers are decorrelated the speech is unintelligible, although the within frequency modulation characteristics remains identical. Used as a masker as above, the information masking accounted for 37% of the spatial unmasking seen with this masker. This unintelligible and highly differentiable masker is unlikely to involve top-down processes. These data provides strong evidence of bottom-up masking involving speech-like, within-frequency modulations and that this, presumably low level process, can be modulated by selective spatial attention. PMID:25727100

  19. Selective spatial attention modulates bottom-up informational masking of speech.

    PubMed

    Carlile, Simon; Corkhill, Caitlin

    2015-03-02

    To hear out a conversation against other talkers listeners overcome energetic and informational masking. Largely attributed to top-down processes, information masking has also been demonstrated using unintelligible speech and amplitude-modulated maskers suggesting bottom-up processes. We examined the role of speech-like amplitude modulations in information masking using a spatial masking release paradigm. Separating a target talker from two masker talkers produced a 20 dB improvement in speech reception threshold; 40% of which was attributed to a release from informational masking. When across frequency temporal modulations in the masker talkers are decorrelated the speech is unintelligible, although the within frequency modulation characteristics remains identical. Used as a masker as above, the information masking accounted for 37% of the spatial unmasking seen with this masker. This unintelligible and highly differentiable masker is unlikely to involve top-down processes. These data provides strong evidence of bottom-up masking involving speech-like, within-frequency modulations and that this, presumably low level process, can be modulated by selective spatial attention.

  20. A cluster randomized clinical trial comparing fit‐tested and non‐fit‐tested N95 respirators to medical masks to prevent respiratory virus infection in health care workers

    PubMed Central

    MacIntyre, Chandini Raina; Wang, Quanyi; Cauchemez, Simon; Seale, Holly; Dwyer, Dominic E.; Yang, Peng; Shi, Weixian; Gao, Zhanhai; Pang, Xinghuo; Zhang, Yi; Wang, Xiaoli; Duan, Wei; Rahman, Bayzidur; Ferguson, Neil

    2011-01-01

    Please cite this paper as: MacIntyre et al. (2011) A cluster randomized clinical trial comparing fit‐tested and non‐fit‐tested N95 respirators to medical masks to prevent respiratory virus infection in health care workers. Influenza and Other Respiratory Viruses DOI: 10.1111/j.1750‐2659.2010.00198.x. Background  We compared the efficacy of medical masks, N95 respirators (fit tested and non fit tested), in health care workers (HCWs). Methods  A cluster randomized clinical trial (RCT) of 1441 HCWs in 15 Beijing hospitals was performed during the 2008/2009 winter. Participants wore masks or respirators during the entire work shift for 4 weeks. Outcomes included clinical respiratory illness (CRI), influenza‐like illness (ILI), laboratory‐confirmed respiratory virus infection and influenza. A convenience no‐mask/respirator group of 481 health workers from nine hospitals was compared. Findings  The rates of CRI (3·9% versus 6·7%), ILI (0·3% versus 0·6%), laboratory‐confirmed respiratory virus (1·4% versus 2·6%) and influenza (0·3% versus 1%) infection were consistently lower for the N95 group compared to medical masks. By intention‐to‐treat analysis, when P values were adjusted for clustering, non‐fit‐tested N95 respirators were significantly more protective than medical masks against CRI, but no other outcomes were significant. The rates of all outcomes were higher in the convenience no‐mask group compared to the intervention arms. There was no significant difference in outcomes between the N95 arms with and without fit testing. Rates of fit test failure were low. In a post hoc analysis adjusted for potential confounders, N95 masks and hospital level were significant, but medical masks, vaccination, handwashing and high‐risk procedures were not. Interpretation  Rates of infection in the medical mask group were double that in the N95 group. A benefit of respirators is suggested but would need to be confirmed by a larger trial, as this study may have been underpowered. The finding on fit testing is specific to the type of respirator used in the study and cannot be generalized to other respirators. Trial registration  Australian New Zealand Clinical Trials Registry (ANZCTR), ACTRN: ACTRN12609000257268 (http://www.anzctr.org.au). PMID:21477136

  1. Reducing personal exposure to particulate air pollution improves cardiovascular health in patients with coronary heart disease.

    PubMed

    Langrish, Jeremy P; Li, Xi; Wang, Shengfeng; Lee, Matthew M Y; Barnes, Gareth D; Miller, Mark R; Cassee, Flemming R; Boon, Nicholas A; Donaldson, Ken; Li, Jing; Li, Liming; Mills, Nicholas L; Newby, David E; Jiang, Lixin

    2012-03-01

    Air pollution exposure increases cardiovascular morbidity and mortality and is a major global public health concern. We investigated the benefits of reducing personal exposure to urban air pollution in patients with coronary heart disease. In an open randomized crossover trial, 98 patients with coronary heart disease walked on a predefined route in central Beijing, China, under different conditions: once while using a highly efficient face mask, and once while not using the mask. Symptoms, exercise, personal air pollution exposure, blood pressure, heart rate, and 12-lead electrocardiography were monitored throughout the 24-hr study period. Ambient air pollutants were dominated by fine and ultrafine particulate matter (PM) that was present at high levels [74 μg/m³ for PM(2.5) (PM with aerodynamic diamater <2.5 µm)]. Consistent with traffic-derived sources, this PM contained organic carbon and polycyclic aromatic hydrocarbons and was highly oxidizing, generating large amounts of free radicals. The face mask was well tolerated, and its use was associated with decreased self-reported symptoms and reduced maximal ST segment depression (-142 vs. -156 μV, p = 0.046) over the 24-hr period. When the face mask was used during the prescribed walk, mean arterial pressure was lower (93 ± 10 vs. 96 ± 10 mmHg, p = 0.025) and heart rate variability increased (high-frequency power: 54 vs. 40 msec², p = 0.005; high-frequency normalized power: 23.5 vs. 20.5 msec, p = 0.001; root mean square successive differences: 16.7 vs. 14.8 msec, p = 0.007). However, mask use did not appear to influence heart rate or energy expenditure. Reducing personal exposure to air pollution using a highly efficient face mask appeared to reduce symptoms and improve a range of cardiovascular health measures in patients with coronary heart disease. Such interventions to reduce personal exposure to PM air pollution have the potential to reduce the incidence of cardiovascular events in this highly susceptible population.

  2. Non-invasive ventilation: evaluation of CO2 washout by intentional leaking in three recent oronasal masks. A pilot study.

    PubMed

    Medrinal, C; Prieur, G; Contal, O; Villiot-Danger, E; Doyle, C; Reychler, G; Quieffin, J

    2015-05-01

    Many types of interfaces with intentional leaks exist for Non Invasive Ventilation. The purpose of intentional leaks is to remove CO2 from the interface, however the calibration does not allow a sufficiently large flow and rebreathing of CO2 can occur. The aim of this study was to compare the CO2 rinsing capacities of three new generation oronasal masks with intentional leaks (A: Quattro®, [Resmed]; B: Amara® [Respironics]; C: Forma® [Fisher&Paykel]) in healthy subjects. Seventeen healthy volunteers were included in this prospective cross-sectional, randomized, double-blinded trial. Each subject underwent ventilation with a home ventilator (IPAP: 14 cmH2O; EPAP: 4 cmH2O) with each mask consecutively. Transcutaneous capnography (PtcCO2) recordings were carried out throughout the trial and ventilator data (tidal volume, respiratory rate, minute ventilation and unintentional leaks) were also analyzed. Mask comfort was assessed using a visual analog scale (0 to 10). The results showed no differences in PtcCO2 between masks (P=0.82). There were no significant differences in respiratory parameters (tidal volume, P=0.79; respiratory rate, P=0.65; minute ventilation, P=0.12) between masks. The rate of unintentional leaks were significantly lower for Mask A (P=0.016). Subjects rated Mask A and Mask C as more comfortable than Mask B (P=0.041). There was no effect of mask on PtcCO2 in healthy subjects. The mask with the highest comfort rating had not the lowest rate of unintentional leaks.

  3. Delivery of helium–oxygen mixture during spontaneous breathing: evaluation of three high-concentration face masks.

    PubMed

    Roche-Campo, Ferran; Vignaux, Laurence; Galia, Fabrice; Lyazidi, Aissam; Vargas, Frédéric; Texereau, Joëlle; Apiou-Sbirlea, Gabriela; Jolliet, Philippe; Brochard, Laurent

    2011-11-01

    To evaluate the efficacy of delivering a mixture of helium and oxygen gas (He–O2) in spontaneous ventilation. Three high oxygen flow reservoir masks were tested: the Heliox21, specifically designed for helium; the Hi-Ox80 mask, with an inspiratory and an expiratory valve; and a standard high-concentration face mask. This prospective randomized crossover study was performed in six healthy volunteers in a laboratory setting. Volunteers breathed a mixture of 78% He/22% O2 through each of the masks under two different breathing conditions (rest and hyperventilation: minute ventilation of 14.9 ± 6.1 and 26.7 ± 8.7 L min(−1), respectively) and four different He–O2 flow rates (7, 10, 12, and 15 L min(−1)). A nasopharyngeal catheter was used to estimate He pharyngeal concentration (Fp [He]) in the airways in order to determine the percentage of contamination with room air (% air cont) at end-expiration. Under all testing conditions, the Hi-Ox80 mask presented a significantly lower % air cont. During resting breathing pattern, a Fp [He] higher than 50% was achieved in 54% of the tests performed with the Hi-Ox80 mask compared to 29% for the Heliox21 mask and only 17% for the standard mask. At hyperventilation, a Fp [He] higher than 50% was achieved in 17% of the tests performed with the Hi-Ox mask compared to 4% for the other two masks. He–O2 administration via the usual high-concentration reservoir masks results in significant dilution by room air. The Hi-Ox80 mask minimized room air contamination and much more frequently achieved a pharyngeal He concentration higher than 50%.

  4. Scatterometry measurement of nested lines, dual space, and rectangular contact CD on phase-shift masks

    NASA Astrophysics Data System (ADS)

    Lee, Kyung M.; Yedur, Sanjay; Henrichs, Sven; Tavassoli, Malahat; Baik, Kiho

    2007-03-01

    Evaluation of lithography process or stepper involves very large quantity of CD measurements and measurement time. In this paper, we report on a application of Scatterometry based metrology for evaluation of binary photomask lithography. Measurements were made on mask level with ODP scatterometer then on wafer with CD-SEM. 4 to 1 scaling from mask to wafer means 60nm line on wafer translates to 240nm on mask, easily measurable on ODP. Calculation of scatterometer profile information was performed by a in-situ library-based analysis (5sec/site). We characterized the CD uniformity, linearity, and metal film thickness uniformity. Results show that linearity measured from fixed-pitch, varying line/space ratio targets show good correlation to top-down CD-SEM with R2 of more than 0.99. ODP-SEM correlation results for variable pitch shows that careful examination of scatterometer profile results in order to obtain better correlation to CD SEM, since both tools react differently to the target profile variation. ODP results show that global CD distribution is clearly measurable with less outliers compared to CD SEM data. This is thought to be due to 'averaging' effect of scatterometer. The data show that Scatterometry provides a nondestructive and faster mean of characterizing lithography stepper performanceprofiles. APSM 1st level (before Cr removal) 'dual-space' CDs and EPSM rectangular contacts were also measured with and results demonstrates that Scatterometer is capable of measuring these targets with reasonable correlation to SEM.

  5. Electroconvulsive therapy can benefit from controlled hyperventilation using a laryngeal mask.

    PubMed

    Haeck, Martina; Gillmann, Benjamin; Janouschek, Hildegard; Grözinger, Michael

    2011-11-01

    Hypocapnia through hyperventilation is a well-known procedure in electroconvulsive therapy (ECT) to enhance seizure activity. However, it has mostly been applied in an uncontrolled manner. Originally intended for a better management of the supraglottic airway, laryngeal masks are more suited to monitor levels of CO(2) during hyperventilation than face masks and thereby provide for the possibility of controlled hyperventilation (CHV). The impact of CHV was retrospectively studied in 114 consecutive patients; 65 of them had received ECT with CHV and 49 had received ECT with uncontrolled hyperventilation (UHV) directly prior to the time period when the laryneal mask was introduced to the ECT treatment procedure. The CO(2) level in the CHV group was aimed at 30 mmHg or below. CHV considerably enhanced the seizure activity leading to changes in clinically determined parameters of the treatment course: the necessity for increasing the electric charge, for re-stimulations (trend) and for bilateral stimulations was lower in the CHV group as compared to the UHV group. The improvement in the Global Assessment of Functioning Scores was not different in both groups. CHV was associated with a higher amount of prolonged seizures, with a reduced number of delirious symptoms after treatments and an attenuating effect on heart rate. Concluding, CHV can help to maintain the applied electric charge low without worsening the clinical outcome. Therefore, it is a helpful technical improvement. However, it should be used carefully with regard to prolonged seizures.

  6. Binaural unmasking with multiple adjacent masking electrodes in bilateral cochlear implant users

    PubMed Central

    Lu, Thomas; Litovsky, Ruth; Zeng, Fan-Gang

    2011-01-01

    Bilateral cochlear implant (BiCI) users gain an advantage in noisy situations from a second implant, but their bilateral performance falls short of normal hearing listeners. Channel interactions due to overlapping electrical fields between electrodes can impair speech perception, but its role in limiting binaural hearing performance has not been well characterized. To address the issue, binaural masking level differences (BMLD) for a 125 Hz tone in narrowband noise were measured using a pair of pitch-matched electrodes while simultaneously presenting the same masking noise to adjacent electrodes, representing a more realistic stimulation condition compared to prior studies that used only a single electrode pair. For five subjects, BMLDs averaged 8.9 ± 1.0 dB (mean ± s.e.) in single electrode pairs but dropped to 2.1 ± 0.4 dB when presenting noise on adjacent masking electrodes, demonstrating a negative impact of the additional maskers. Removing the masking noise from only the pitch-matched electrode pair not only lowered thresholds but also resulted in smaller BMLDs. The degree of channel interaction estimated from auditory nerve evoked potentials in three subjects was significantly and negatively correlated with BMLD. The data suggest that if the amount of channel interactions can be reduced, BiCI users may experience some performance improvements related to binaural hearing. PMID:21682415

  7. AutoMOPS- B2B and B2C in mask making: Mask manufacturing performance and customer satisfaction improvement through better information flow management using generic models and standardized languages

    NASA Astrophysics Data System (ADS)

    Filies, Olaf; de Ridder, Luc; Rodriguez, Ben; Kujiken, Aart

    2002-03-01

    Semiconductor manufacturing has become a global business, in which companies of different size unite in virtual enterprises to meet new opportunities. Therefore Mask manufacturing is a key business, but mask ordering is a complex process and is always critical regarding design to market time, even though mask complexity and customer base are increasing using a wide variety of different mask order forms which are frequently faulty and very seldom complete. This is effectively blocking agile manufacturing and can tie wafer fabs to a single mask The goal of the project is elimination of the order verification through paperless, electronically linked information sharing/exchange between chip design, mask production and production stages, which will allow automation of the mask preparation. To cover these new techniques and their specifications as well as the common ones with automated tools a special generic Meta-model will be generated, based on the current standards for mask specifications, including the requirements from the involved partners (Alcatel Microelectronics, Altis, Compugraphics, Infineon, Nimble, Sigma-C), the project works out a pre-normative standard. The paper presents the current status of work. This work is partly funded by the Commission of the European Union under the Fifth Framework project IST-1999-10332 AutoMOPS.

  8. Rates of initial acceptance of PAP masks and outcomes of mask switching.

    PubMed

    Bachour, Adel; Vitikainen, Pirjo; Maasilta, Paula

    2016-05-01

    Recently, we noticed a considerable development in alleviating problems related to positive airway pressure (PAP) masks. In this study, we report on the initial PAP mask acceptance rates and the effects of mask switching on mask-related symptoms. We prospectively collected all cases of mask switching in our sleep unit for a period of 14 months. At the time of the study, we used ResMed™ CPAP devices and masks. Mask switching was defined as replacing a mask used for at least 1 day with another type of mask. Changing to a different size but keeping the same type of mask did not count as mask switching. Switching outcomes were considered failed if the initial problem persisted or reappeared during the year that followed switching. Our patient pool was 2768. We recorded 343 cases of mask switching among 267 patients. Of the 566 patients who began new PAP therapy, 108 (39 women) had switched masks, yielding an initial mask acceptance rate of 81 %. The reason for switching was poor-fit/uncomfortable mask in 39 %, leak-related in 30 %, outdated model in 25 %, and nasal stuffiness in 6 % of cases; mask switching resolved these problems in 61 %. Mask switching occurred significantly (p = 0.037) more often in women and in new PAP users. The odds ratio for abandoning PAP therapy within 1 year after mask switching was 7.2 times higher (interval 4.7-11.1) than not switching masks. The initial PAP mask acceptance rate was high. Patients who switched their masks are at greater risk for abandoning PAP therapy.

  9. High-Level Psychophysical Tuning Curves: Forward Masking in Normal-Hearing and Hearing-Impaired Listeners.

    ERIC Educational Resources Information Center

    Nelson, David A.

    1991-01-01

    Forward-masked psychophysical tuning curves were obtained at multiple probe levels from 26 normal-hearing listeners and 24 ears of 21 hearing-impaired listeners with cochlear hearing loss. Results indicated that some cochlear hearing losses influence the sharp tuning capabilities usually associated with outer hair cell function. (Author/JDD)

  10. Foul tip impact attenuation of baseball catcher masks using head impact metrics

    PubMed Central

    White, Terrance R.; Cutcliffe, Hattie C.; Shridharani, Jay K.; Wood, Garrett W.; Bass, Cameron R.

    2018-01-01

    Currently, no scientific consensus exists on the relative safety of catcher mask styles and materials. Due to differences in mass and material properties, the style and material of a catcher mask influences the impact metrics observed during simulated foul ball impacts. The catcher surrogate was a Hybrid III head and neck equipped with a six degree of freedom sensor package to obtain linear accelerations and angular rates. Four mask styles were impacted using an air cannon for six 30 m/s and six 35 m/s impacts to the nasion. To quantify impact severity, the metrics peak linear acceleration, peak angular acceleration, Head Injury Criterion, Head Impact Power, and Gadd Severity Index were used. An Analysis of Covariance and a Tukey’s HSD Test were conducted to compare the least squares mean between masks for each head injury metric. For each injury metric a P-Value less than 0.05 was found indicating a significant difference in mask performance. Tukey’s HSD test found for each metric, the traditional style titanium mask fell in the lowest performance category while the hockey style mask was in the highest performance category. Limitations of this study prevented a direct correlation from mask testing performance to mild traumatic brain injury. PMID:29856814

  11. Discussion and a new method of optical cryptosystem based on interference

    NASA Astrophysics Data System (ADS)

    Lu, Dajiang; He, Wenqi; Liao, Meihua; Peng, Xiang

    2017-02-01

    A discussion and an objective security analysis of the well-known optical image encryption based on interference are presented in this paper. A new method is also proposed to eliminate the security risk of the original cryptosystem. For a possible practical application, we expand this new method into a hierarchical authentication scheme. In this authentication system, with a pre-generated and fixed random phase lock, different target images indicating different authentication levels are analytically encoded into corresponding phase-only masks (phase keys) and amplitude-only masks (amplitude keys). For the authentication process, a legal user can obtain a specified target image at the output plane if his/her phase key, and amplitude key, which should be settled close against the fixed internal phase lock, are respectively illuminated by two coherent beams. By comparing the target image with all the standard certification images in the database, the system can thus verify the user's legality even his/her identity level. Moreover, in despite of the internal phase lock of this system being fixed, the crosstalk between different pairs of keys held by different users is low. Theoretical analysis and numerical simulation are both provided to demonstrate the validity of this method.

  12. Electrophysiological Evidence for the Sources of the Masking Level Difference.

    PubMed

    Fowler, Cynthia G

    2017-08-16

    The purpose of this review article is to review evidence from auditory evoked potential studies to describe the contributions of the auditory brainstem and cortex to the generation of the masking level difference (MLD). A literature review was performed, focusing on the auditory brainstem, middle, and late latency responses used in protocols similar to those used to generate the behavioral MLD. Temporal coding of the signals necessary for generating the MLD occurs in the auditory periphery and brainstem. Brainstem disorders up to wave III of the auditory brainstem response (ABR) can disrupt the MLD. The full MLD requires input to the generators of the auditory late latency potentials to produce all characteristics of the MLD; these characteristics include threshold differences for various binaural signal and noise conditions. Studies using central auditory lesions are beginning to identify the cortical effects on the MLD. The MLD requires auditory processing from the periphery to cortical areas. A healthy auditory periphery and brainstem codes temporal synchrony, which is essential for the ABR. Threshold differences require engaging cortical function beyond the primary auditory cortex. More studies using cortical lesions and evoked potentials or imaging should clarify the specific cortical areas involved in the MLD.

  13. Altered affective response in marijuana smokers: an FMRI study.

    PubMed

    Gruber, Staci A; Rogowska, Jadwiga; Yurgelun-Todd, Deborah A

    2009-11-01

    More than 94 million Americans have tried marijuana, and it remains the most widely used illicit drug in the nation. Investigations of the cognitive effects of marijuana report alterations in brain function during tasks requiring executive control, including inhibition and decision-making. Endogenous cannabinoids regulate a variety of emotional responses, including anxiety, mood control, and aggression; nevertheless, little is known about smokers' responses to affective stimuli. The anterior cingulate and amygdala play key roles in the inhibition of impulsive behavior and affective regulation, and studies using PET and fMRI have demonstrated changes within these regions in marijuana smokers. Given alterations in mood and perception often observed in smokers, we hypothesized altered fMRI patterns of response in 15 chronic heavy marijuana smokers relative to 15 non-marijuana smoking control subjects during the viewing of masked happy and fearful faces. Despite no between-group differences on clinical or demographic measures, smokers demonstrated a relative decrease in both anterior cingulate and amygdalar activity during masked affective stimuli compared to controls, who showed relative increases in activation within these regions during the viewing of masked faces. Findings indicate that chronic heavy marijuana smokers demonstrate altered activation of frontal and limbic systems while viewing masked faces, consistent with autoradiographic studies reporting high CB-1 receptor density in these regions. These data suggest differences in affective processing in chronic smokers, even when stimuli are presented below the level of conscious processing, and underscore the likelihood that marijuana smokers process emotional information differently from those who do not smoke, which may result in negative consequences.

  14. A diffusion model account of masked vs. unmasked priming: Are they qualitatively different?

    PubMed Central

    Gomez, Pablo; Perea, Manuel; Ratcliff, Roger

    2017-01-01

    In the past decades, hundreds of articles have explored the mechanisms underlying priming. Most researchers assume that masked and unmasked priming are qualitatively different. For masked priming, the effects are often assumed to reflect savings in the encoding of the target stimulus, whereas for unmasked priming, it has been suggested that the effects reflect the familiarity of the prime-target compound cue. In contrast, other researchers have claimed that masked and unmasked priming reflect essentially the same core processes. In this article, we use the diffusion model (Ratcliff, 1978) to account for the effects of masked and unmasked priming for identity and associatively related primes. The fits of the model lead us to the following conclusion: masked related primes give a head start to the processing of the target compared to unrelated primes, while unmasked priming affects primarily the quality of the lexical information. PMID:23647337

  15. Effectiveness of surgical masks against influenza bioaerosols.

    PubMed

    Makison Booth, C; Clayton, M; Crook, B; Gawn, J M

    2013-05-01

    Most surgical masks are not certified for use as respiratory protective devices (RPDs). In the event of an influenza pandemic, logistical and practical implications such as storage and fit testing will restrict the use of RPDs to certain high-risk procedures that are likely to generate large amounts of infectious bioaerosols. Studies have shown that in such circumstances increased numbers of surgical masks are worn, but the protection afforded to the wearer by a surgical mask against infectious aerosols is not well understood. To develop and apply a method for assessing the protection afforded by surgical masks against a bioaerosol challenge. A dummy test head attached to a breathing simulator was used to test the performance of surgical masks against a viral challenge. Several designs of surgical masks commonly used in the UK healthcare sector were evaluated by measuring levels of inert particles and live aerosolised influenza virus in the air, from in front of and behind each mask. Live influenza virus was measurable from the air behind all surgical masks tested. The data indicate that a surgical mask will reduce exposure to aerosolised infectious influenza virus; reductions ranged from 1.1- to 55-fold (average 6-fold), depending on the design of the mask. We describe a workable method to evaluate the protective efficacy of surgical masks and RPDs against a relevant aerosolised biological challenge. The results demonstrated limitations of surgical masks in this context, although they are to some extent protective. Crown Copyright © 2013. Published by Elsevier Ltd. All rights reserved.

  16. Force-dependent static dead space of face masks used with holding chambers.

    PubMed

    Shah, Samir A; Berlinski, Ariel B; Rubin, Bruce K

    2006-02-01

    Pressurized metered-dose inhalers with valved holding chambers and masks are commonly used for aerosol delivery in children. Drug delivery can decrease when the dead-space volume (DSV) of the valved holding chamber is increased, but there are no published data evaluating force-dependent DSV among different masks. Seven masks were studied. Masks were sealed at the valved holding chamber end and filled with water to measure mask volume. To measure mask DSV we used a mannequin of 2-year-old-size face and we applied the mask with forces of 1.5, 3.5, and 7 pounds. Mask seal was determined by direct observation. Intra-brand analysis was done via analysis of variance. At 3.5 pounds of force, the DSV ranged from 29 mL to 100 mL, with 3 masks having DSV of < 50 mL. The remaining masks all had DSV > 60 mL. At 3.5 pounds of force, DSV percent of mask volume ranged from 33.7% (Aerochamber, p < 0.01 compared with other masks) to 100% (Pocket Chamber). DSV decreased with increasing force with most of the masks, and the slope of this line was inversely proportional to mask flexibility. Mask fit was 100% at 1.5 pounds of force only with the Aerochamber and Optichamber. Mask fit was poorest with the Vortex, Pocket Chamber, and BreatheRite masks. Rigid masks with large DSV might not be not suitable for use in children, especially if discomfort from the stiff mask makes its use less acceptable to the child.

  17. Sandwich masking eliminates both visual awareness of faces and face-specific brain activity through a feedforward mechanism.

    PubMed

    Harris, Joseph A; Wu, Chien-Te; Woldorff, Marty G

    2011-06-07

    It is generally agreed that considerable amounts of low-level sensory processing of visual stimuli can occur without conscious awareness. On the other hand, the degree of higher level visual processing that occurs in the absence of awareness is as yet unclear. Here, event-related potential (ERP) measures of brain activity were recorded during a sandwich-masking paradigm, a commonly used approach for attenuating conscious awareness of visual stimulus content. In particular, the present study used a combination of ERP activation contrasts to track both early sensory-processing ERP components and face-specific N170 ERP activations, in trials with versus without awareness. The electrophysiological measures revealed that the sandwich masking abolished the early face-specific N170 neural response (peaking at ~170 ms post-stimulus), an effect that paralleled the abolition of awareness of face versus non-face image content. Furthermore, however, the masking appeared to render a strong attenuation of earlier feedforward visual sensory-processing signals. This early attenuation presumably resulted in insufficient information being fed into the higher level visual system pathways specific to object category processing, thus leading to unawareness of the visual object content. These results support a coupling of visual awareness and neural indices of face processing, while also demonstrating an early low-level mechanism of interference in sandwich masking.

  18. Associative and repetition priming with the repeated masked prime technique: no priming found.

    PubMed

    Avons, S E; Russo, Riccardo; Cinel, Caterina; Verolini, Veronica; Glynn, Kevin; McDonald, Rebecca; Cameron, Marie

    2009-01-01

    Wentura and Frings (2005) reported evidence of subliminal categorical priming on a lexical decision task, using a new method of visual masking in which the prime string consisted of the prime word flanked by random consonants and random letter masks alternated with the prime string on successive refresh cycles. We investigated associative and repetition priming on lexical decision, using the same method of visual masking. Three experiments failed to show any evidence of associative priming, (1) when the prime string was fixed at 10 characters (three to six flanking letters) and (2) when the number of flanking letters were reduced or absent. In all cases, prime detection was at chance level. Strong associative priming was observed with visible unmasked primes, but the addition of flanking letters restricted priming even though prime detection was still high. With repetition priming, no priming effects were found with the repeated masked technique, and prime detection was poor but just above chance levels. We conclude that with repeated masked primes, there is effective visual masking but that associative priming and repetition priming do not occur with experiment-unique prime-target pairs. Explanations for this apparent discrepancy across priming paradigms are discussed. The priming stimuli and prime-target pairs used in this study may be downloaded as supplemental materials from mc.psychonomic-journals.org/content/supplemental.

  19. Hot spot variability and lithography process window investigation by CDU improvement using CDC technique

    NASA Astrophysics Data System (ADS)

    Thamm, Thomas; Geh, Bernd; Djordjevic Kaufmann, Marija; Seltmann, Rolf; Bitensky, Alla; Sczyrba, Martin; Samy, Aravind Narayana

    2018-03-01

    Within the current paper, we will concentrate on the well-known CDC technique from Carl Zeiss to improve the CD distribution of the wafer by improving the reticle CDU and its impact on hotspots and Litho process window. The CDC technique uses an ultra-short pulse laser technology, which generates a micro-level Shade-In-Element (also known as "Pixels") into the mask quartz bulk material. These scatter centers are able to selectively attenuate certain areas of the reticle in higher resolution compared to other methods and thus improve the CD uniformity. In a first section, we compare the CDC technique with scanner dose correction schemes. It becomes obvious, that the CDC technique has unique advantages with respect to spatial resolution and intra-field flexibility over scanner correction schemes, however, due to the scanner flexibility across wafer both methods are rather complementary than competing. In a second section we show that a reference feature based correction scheme can be used to improve the CDU of a full chip with multiple different features that have different MEEF and dose sensitivities. In detail we will discuss the impact of forward scattering light originated by the CDC pixels on the illumination source and the related proximity signature. We will show that the impact on proximity is small compared to the CDU benefit of the CDC technique. Finally we show to which extend the reduced variability across reticle will result in a better common electrical process window of a whole chip design on the whole reticle field on wafer. Finally we will discuss electrical verification results between masks with purposely made bad CDU that got repaired by the CDC technique versus inherently good "golden" masks on a complex logic device. No yield difference is observed between the repaired bad masks and the masks with good CDU.

  20. WHOLE FROG TECHNICAL REPORT

    Science.gov Websites

    able to represent the anatomy of a frog in a computer in 3D space in such a way that a high school few masks to be loaded at once and enables different masks to be exclusive. When a mask becomes can not be drawn on. This method avoids overlapping masks when segmenting objects are adjacent to each

  1. Cognitive disorganisation in schizotypy is associated with deterioration in visual backward masking.

    PubMed

    Cappe, Céline; Herzog, Michael H; Herzig, Daniela A; Brand, Andreas; Mohr, Christine

    2012-12-30

    To understand the causes of schizophrenia, a search for stable markers (endophenotypes) is ongoing. In previous years, we have shown that the shine-through visual backward masking paradigm meets the most important characteristics of an endophenotype. Here, we tested masking performance differences between healthy students with low and high schizotypy scores as determined by the self-report O-Life questionnaire assessing schizotypy along three dimensions, i.e. positive schizotypy (unusual experiences), cognitive disorganisation, and negative schizotypy (introvertive anhedonia). Forty participants performed the shine-through backward masking task and a classical cognitive test, the Wisconsin Card Sorting Task (WCST). We found that visual backward masking was impaired for students scoring high as compared to low on the cognitive disorganisation dimension, whereas the positive and negative schizotypy dimensions showed no link to masking performance. We also found group differences for students scoring high and low on the cognitive disorganisation factor for the WCST. These findings indicate that the shine-through paradigm is sensitive to differences in schizotypy which are closely linked with the pathological expression in schizophrenia. Copyright © 2012 Elsevier Ireland Ltd. All rights reserved.

  2. Masked nonword repetition effects in yes/no and go/no-go lexical decision: a test of the evidence accumulation and deadline accounts.

    PubMed

    Perea, Manuel; Gómez, Pablo; Fraga, Isabel

    2010-06-01

    The pattern of masked repetition priming effects for word and nonword targets differs across tasks: Masked-priming effects in lexical decision occur for positive responses (i.e., words), but not for negative responses (nonwords), whereas masked-priming effects in the cross-case same-different task occur for positive responses (same), but not for negative responses (different)--regardless of lexical status. Here, we examined whether masked nonword priming effects are greater when the task involves an active go response to nonwords than when it involves the standard yes/no procedure in lexical decision. The obtained masked repetition priming effect for nonwords was of similar size in yes/no and go/no-go tasks. This finding is compatible with accounts of nonword priming that posit that nonword responses are produced by actively accumulating evidence for the nonword alternative in yes/no and go/no-go procedures, whereas it is inconsistent with the assumption of a deadline for no responses in the yes/no task.

  3. More Realistic Face Model Surface Improves Relevance of Pediatric In-Vitro Aerosol Studies

    PubMed Central

    Amirav, Israel; Halamish, Asaf; Gorenberg, Miguel; Omar, Hamza; Newhouse, Michael T.

    2015-01-01

    Background Various hard face models are commonly used to evaluate the efficiency of aerosol face masks. Softer more realistic “face” surface materials, like skin, deform upon mask application and should provide more relevant in-vitro tests. Studies that simultaneously take into consideration many of the factors characteristic of the in vivo face are lacking. These include airways, various application forces, comparison of various devices, comparison with a hard-surface model and use of a more representative model face based on large numbers of actual faces. Aim To compare mask to “face” seal and aerosol delivery of two pediatric masks using a soft vs. a hard, appropriately representative, pediatric face model under various applied forces. Methods Two identical face models and upper airways replicas were constructed, the only difference being the suppleness and compressibility of the surface layer of the “face.” Integrity of the seal and aerosol delivery of two different masks [AeroChamber (AC) and SootherMask (SM)] were compared using a breath simulator, filter collection and realistic applied forces. Results The soft “face” significantly increased the delivery efficiency and the sealing characteristics of both masks. Aerosol delivery with the soft “face” was significantly greater for the SM compared to the AC (p< 0.01). No statistically significant difference between the two masks was observed with the hard “face.” Conclusions The material and pliability of the model “face” surface has a significant influence on both the seal and delivery efficiency of face masks. This finding should be taken into account during in-vitro aerosol studies. PMID:26090661

  4. Effects of hard mask etch on final topography of advanced phase shift masks

    NASA Astrophysics Data System (ADS)

    Hortenbach, Olga; Rolff, Haiko; Lajn, Alexander; Baessler, Martin

    2017-07-01

    Continuous shrinking of the semiconductor device dimensions demands steady improvements of the lithographic resolution on wafer level. These requirements challenge the photomask industry to further improve the mask quality in all relevant printing characteristics. In this paper topography of the Phase Shift Masks (PSM) was investigated. Effects of hard mask etch on phase shift uniformity and mask absorber profile were studied. Design of experiments method (DoE) was used for the process optimization, whereas gas composition, bias power of the hard mask main etch and bias power of the over-etch were varied. In addition, influence of the over-etch time was examined at the end of the experiment. Absorber depth uniformity, sidewall angle (SWA), reactive ion etch lag (RIE lag) and through pitch (TP) dependence were analyzed. Measurements were performed by means of Atomic-force microscopy (AFM) using critical dimension (CD) mode with a boot-shaped tip. Scanning electron microscope (SEM) cross-section images were prepared to verify the profile quality. Finally CD analysis was performed to confirm the optimal etch conditions. Significant dependence of the absorber SWA on hard mask (HM) etch conditions was observed revealing an improvement potential for the mask absorber profile. It was found that hard mask etch can leave a depth footprint in the absorber layer. Thus, the etch depth uniformity of hard mask etch is crucial for achieving a uniform phase shift over the active mask area. The optimized hard mask etch process results in significantly improved mask topography without deterioration of tight CD specifications.

  5. Optical proximity correction for anamorphic extreme ultraviolet lithography

    NASA Astrophysics Data System (ADS)

    Clifford, Chris; Lam, Michael; Raghunathan, Ananthan; Jiang, Fan; Fenger, Germain; Adam, Kostas

    2017-10-01

    The change from isomorphic to anamorphic optics in high numerical aperture extreme ultraviolet scanners necessitates changes to the mask data preparation flow. The required changes for each step in the mask tape out process are discussed, with a focus on optical proximity correction (OPC). When necessary, solutions to new problems are demonstrated and verified by rigorous simulation. Additions to the OPC model include accounting for anamorphic effects in the optics, mask electromagnetics, and mask manufacturing. The correction algorithm is updated to include awareness of anamorphic mask geometry for mask rule checking. OPC verification through process window conditions is enhanced to test different wafer scale mask error ranges in the horizontal and vertical directions. This work will show that existing models and methods can be updated to support anamorphic optics without major changes. Also, the larger mask size in the Y direction can result in better model accuracy, easier OPC convergence, and designs that are more tolerant to mask errors.

  6. Physiological evaluation of a modified jet transport passenger oxygen mask.

    DOT National Transportation Integrated Search

    1972-03-01

    The paper describes altitude chamber experiments conducted with human subjects using a new continuous-flow disposable passenger mask applicable for emergency use to maximum altitudes of 41,000 feet. This mask design differs in configuration from the ...

  7. Gaps, Conflicts, and Arguments between Adolescents and Their Parents

    ERIC Educational Resources Information Center

    Fuligni, Andrew J.

    2012-01-01

    Parent-adolescent conflict appears to be similar across different immigrant generations and cultural groups in frequency and implications for adjustment. However, the same level of argumentation may mask hidden conflictual feelings that are not expressed. Why an acculturation gap leads to such conflictual feelings in some adolescents and not…

  8. Polarization-based compensation of astigmatism.

    PubMed

    Chowdhury, Dola Roy; Bhattacharya, Kallol; Chakraborty, Ajay K; Ghosh, Raja

    2004-02-01

    One approach to aberration compensation of an imaging system is to introduce a suitable phase mask at the aperture plane of an imaging system. We utilize this principle for the compensation of astigmatism. A suitable polarization mask used on the aperture plane together with a polarizer-retarder combination at the input of the imaging system provides the compensating polarization-induced phase steps at different quadrants of the apertures masked by different polarizers. The aberrant phase can be considerably compensated by the proper choice of a polarization mask and suitable selection of the polarization parameters involved. The results presented here bear out our theoretical expectation.

  9. Tuning the cognitive environment: Sound masking with 'natural' sounds in open-plan offices

    NASA Astrophysics Data System (ADS)

    DeLoach, Alana

    With the gain in popularity of open-plan office design and the engineering efforts to achieve acoustical comfort for building occupants, a majority of workers still report dissatisfaction in their workplace environment. Office acoustics influence organizational effectiveness, efficiency, and satisfaction through meeting appropriate requirements for speech privacy and ambient sound levels. Implementing a sound masking system is one tried-and-true method of achieving privacy goals. Although each sound masking system is tuned for its specific environment, the signal -- random steady state electronic noise, has remained the same for decades. This research work explores how `natural' sounds may be used as an alternative to this standard masking signal employed so ubiquitously in sound masking systems in the contemporary office environment. As an unobtrusive background sound, possessing the appropriate spectral characteristics, this proposed use of `natural' sounds for masking challenges the convention that masking sounds should be as meaningless as possible. Through the pilot study presented in this work, we hypothesize that `natural' sounds as sound maskers will be as effective at masking distracting background noise as the conventional masking sound, will enhance cognitive functioning, and increase participant (worker) satisfaction.

  10. Optical inspection of NGL masks

    NASA Astrophysics Data System (ADS)

    Pettibone, Donald W.; Stokowski, Stanley E.

    2004-12-01

    For the last five years KLA-Tencor and our joint venture partners have pursued a research program studying the ability of optical inspection tools to meet the inspection needs of possible NGL lithographies. The NGL technologies that we have studied include SCALPEL, PREVAIL, EUV lithography, and Step and Flash Imprint Lithography. We will discuss the sensitivity of the inspection tools and mask design factors that affect tool sensitivity. Most of the work has been directed towards EUV mask inspection and how to optimize the mask to facilitate inspection. Our partners have succeeded in making high contrast EUV masks ranging in contrast from 70% to 98%. Die to die and die to database inspection of EUV masks have been achieved with a sensitivity that is comparable to what can be achieved with conventional photomasks, approximately 80nm defect sensitivity. We have inspected SCALPEL masks successfully. We have found a limitation of optical inspection when applied to PREVAIL stencil masks. We have run inspections on SFIL masks in die to die, reflected light, in an effort to provide feedback to improve the masks. We have used a UV inspection system to inspect both unpatterned EUV substrates (no coatings) and blanks (with EUV multilayer coatings). These inspection results have proven useful in driving down the substrate and blank defect levels.

  11. Reticles, write time, and the need for speed

    NASA Astrophysics Data System (ADS)

    Ackmann, Paul W.; Litt, Lloyd C.; Ning, Guo Xiang

    2014-10-01

    Historical data indicates reticle write times are increasing node-to-node. The cost of mask sets is increasing driven by the tighter requirements and more levels. The regular introduction of new generations of mask patterning tools with improved performance is unable to fully compensate for the increased data and complexity required. Write time is a primary metric that drives mask fabrication speed. Design (Raw data) is only the first step in the process and many interactions between mask and wafer technology such as OPC used, OPC efficiency for writers, fracture engines, and actual field size used drive total write time. Yield, technology, and inspection rules drive the remaining raw cycle time. Yield can be even more critical for speed of delivery as it drives re-writes and wasted time. While intrinsic process yield is important, repair capability is the reason mask delivery is still able to deliver 100% good reticles to the fab. Advanced nodes utilizing several layers of multiple patterning may require mask writer tool dedication to meet image placement specifications. This will increase the effective mask cycle time for a layer mask set and drive the need for additional mask write capability in order to deliver masks at the rate required by the wafer fab production schedules.

  12. The masking of beluga whale (Delphinapterus leucas) vocalizations by icebreaker noise

    NASA Astrophysics Data System (ADS)

    Erbe, Christine

    1998-11-01

    This thesis examines the masking effect of underwater noise on beluga whale communication. As ocean water is greatly opaque for light but well conducting for sound, marine mammals rely primarily on their hearing for orientation and communication. Man-made underwater noise has the potential of interfering with sounds used by marine mammals. Masking to the point of incomprehensibility can have fatal results-for the individual, but ultimately for the entire species. As part of our understanding of whether marine mammals can cope with human impact on nature, this thesis is the first to study the interference of real ocean noises with complex animal vocalizations. At the Vancouver Aquarium, a beluga whale was trained for acoustic experiments, during which masked hearing thresholds were measured. Focus lay on noise created by icebreaking ships in the Arctic. As experiments with trained animals are time and cost expensive, various techniques were examined for their ability to model the whale's response. These were human hearing tests, visual spectrogram discrimination, matched filtering, spectrogram cross-correlation, critical band cross-correlation, adaptive filtering and various types of artificial neural networks. The most efficient method with respect to similarity to the whale's data and speed, was a backpropagation neural net. Masked hearing thresholds would be of little use if they could not be related to accessible quantities in the wild. An ocean sound propagation model was applied to determine critical distances between a noise source, a calling whale and a listening whale. Colour diagrams, called maskograms, were invented to illustrate zones of masking in the wild. Results are that bubbler system noise with a source level of 194 dB re 1 μPa at 1 m has a maximum radius of masking of 15 km in a 3- dimensional ocean. Propeller noise with a source level of 203 dB re 1 μPa at 1 m has a maximum radius of masking of 22 km. A naturally occurring icecracking event with a source level of 147 dB re 1 μPa at 1 m only masks if the listening whale is within 8 m of the event. Therefore, in the wild, propeller cavitation noise masks furthest, followed by bubbler system noise, then icecracking noise.

  13. Interactions between concentric form-from-structure and face perception revealed by visual masking but not adaptation

    PubMed Central

    Feczko, Eric; Shulman, Gordon L.; Petersen, Steven E.; Pruett, John R.

    2014-01-01

    Findings from diverse subfields of vision research suggest a potential link between high-level aspects of face perception and concentric form-from-structure perception. To explore this relationship, typical adults performed two adaptation experiments and two masking experiments to test whether concentric, but not nonconcentric, Glass patterns (a type of form-from-structure stimulus) utilize a processing mechanism shared by face perception. For the adaptation experiments, subjects were presented with an adaptor for 5 or 20 s, prior to discriminating a target. In the masking experiments, subjects saw a mask, then a target, and then a second mask. Measures of discriminability and bias were derived and repeated measures analysis of variance tested for pattern-specific masking and adaptation effects. Results from Experiment 1 show no Glass pattern-specific effect of adaptation to faces; results from Experiment 2 show concentric Glass pattern masking, but not adaptation, may impair upright/inverted face discrimination; results from Experiment 3 show concentric and radial Glass pattern masking impaired subsequent upright/inverted face discrimination more than translational Glass pattern masking; and results from Experiment 4 show concentric and radial Glass pattern masking impaired subsequent face gender discrimination more than translational Glass pattern masking. Taken together, these findings demonstrate interactions between concentric form-from-structure and face processing, suggesting a possible common processing pathway. PMID:24563526

  14. How do different brands of size 1 laryngeal mask airway compare with face mask ventilation in a dedicated laryngeal mask airway teaching manikin?

    PubMed

    Tracy, Mark Brian; Priyadarshi, Archana; Goel, Dimple; Lowe, Krista; Huvanandana, Jacqueline; Hinder, Murray

    2018-05-01

    International neonatal resuscitation guidelines recommend the use of laryngeal mask airway (LMA) with newborn infants (≥34 weeks' gestation or >2 kg weight) when bag-mask ventilation (BMV) or tracheal intubation is unsuccessful. Previous publications do not allow broad LMA device comparison. To compare delivered ventilation of seven brands of size 1 LMA devices with two brands of face mask using self-inflating bag (SIB). 40 experienced neonatal staff provided inflation cycles using SIB with positive end expiratory pressure (PEEP) (5 cmH 2 O) to a specialised newborn/infant training manikin randomised for each LMA and face mask. All subjects received prior education in LMA insertion and BMV. 12 415 recorded inflations for LMAs and face masks were analysed. Leak detected was lowest with i-gel brand, with a mean of 5.7% compared with face mask (triangular 42.7, round 35.7) and other LMAs (45.5-65.4) (p<0.001). Peak inspiratory pressure was higher with i-gel, with a mean of 28.9 cmH 2 O compared with face mask (triangular 22.8, round 25.8) and other LMAs (14.3-22.0) (p<0.001). PEEP was higher with i-gel, with a mean of 5.1 cmH 2 O compared with face mask (triangular 3.0, round 3.6) and other LMAs (0.6-2.6) (p<0.001). In contrast to other LMAs examined, i-gel had no insertion failures and all users found i-gel easy to use. This study has shown dramatic performance differences in delivered ventilation, mask leak and ease of use among seven different brands of LMA tested in a manikin model. This coupled with no partial or complete insertion failures and ease of use suggests i-gel LMA may have an expanded role with newborn resuscitation as a primary resuscitation device. © Article author(s) (or their employer(s) unless otherwise stated in the text of the article) 2018. All rights reserved. No commercial use is permitted unless otherwise expressly granted.

  15. Block-Based Connected-Component Labeling Algorithm Using Binary Decision Trees

    PubMed Central

    Chang, Wan-Yu; Chiu, Chung-Cheng; Yang, Jia-Horng

    2015-01-01

    In this paper, we propose a fast labeling algorithm based on block-based concepts. Because the number of memory access points directly affects the time consumption of the labeling algorithms, the aim of the proposed algorithm is to minimize neighborhood operations. Our algorithm utilizes a block-based view and correlates a raster scan to select the necessary pixels generated by a block-based scan mask. We analyze the advantages of a sequential raster scan for the block-based scan mask, and integrate the block-connected relationships using two different procedures with binary decision trees to reduce unnecessary memory access. This greatly simplifies the pixel locations of the block-based scan mask. Furthermore, our algorithm significantly reduces the number of leaf nodes and depth levels required in the binary decision tree. We analyze the labeling performance of the proposed algorithm alongside that of other labeling algorithms using high-resolution images and foreground images. The experimental results from synthetic and real image datasets demonstrate that the proposed algorithm is faster than other methods. PMID:26393597

  16. Mask cost of ownership for advanced lithography

    NASA Astrophysics Data System (ADS)

    Muzio, Edward G.; Seidel, Philip K.

    2000-07-01

    As technology advances, becoming more difficult and more expensive, the cost of ownership (CoO) metric becomes increasingly important in evaluating technical strategies. The International SEMATECH CoC analysis has steadily gained visibility over the past year, as it attempts to level the playing field between technology choices, and create a fair relative comparison. In order to predict mask cots for advanced lithography, mask process flows are modeled using bets-known processing strategies, equipment cost, and yields. Using a newly revised yield mode, and updated mask manufacture flows, representative mask flows can be built. These flows are then used to calculate mask costs for advanced lithography down to the 50 nm node. It is never the goal of this type of work to provide absolute cost estimates for business planning purposes. However, the combination of a quantifiable yield model with a clearly defined set of mask processing flows and a cost model based upon them serves as an excellent starting point for cost driver analysis and process flow discussion.

  17. Comparison of performance of three different types of respiratory protection devices.

    PubMed

    Lawrence, Robert B; Duling, Matthew G; Calvert, Catherine A; Coffey, Christopher C

    2006-09-01

    Respiratory protection is offered to American workers in a variety of ways to guard against potential inhalation hazards. Two of the most common ways are elastomeric N95 respirators and N95 filtering-facepiece respirators. Some in the health care industry feel that surgical masks provide an acceptable level of protection in certain situations against particular hazards. This study compared the performance of these types of respiratory protection during a simulated workplace test that measured both filter penetration and face-seal leakage. A panel of 25 test subjects with varying face sizes tested 15 models of elastomeric N95 respirators, 15 models of N95 filtering-facepiece respirators, and 6 models of surgical masks. Simulated workplace testing was conducted using a TSI PORTACOUNT Plus model 8020, and consisted of a series of seven exercises. Six simulated workplace tests were performed with redonning of the respirator/mask occurring between each test. The results of these tests produced a simulated workplace protection factor (SWPF). The geometric mean (GM) and the 5th percentile values of the SWPFs were computed by category of respiratory protection using the six overall SWPF values. The level of protection provided by each of the three respiratory protection types was compared. The GM and 5th percentile SWPF values without fit testing were used for the comparison, as surgical masks were not intended to be fit tested. The GM values were 36 for elastomeric N95 respirators, 21 for N95 filtering-facepiece respirators, and 3 for surgical masks. An analysis of variance demonstrated a statistically significant difference between all three. Elastomeric N95 respirators had the highest 5th percentile SWPF of 7. N95 filtering-facepiece respirators and surgical masks had 5th percentile SWPFs of 3 and 1, respectively. A Fisher Exact Test revealed that the 5th percentile SWPFs for all three types of respiratory protection were statistically different. In addition, both qualitative (Bitrex and saccharin) and quantitative (N95-Companion) fit testing were performed on the N95 filtering- and elastomeric-facepiece respirators. It was found that passing a fit test generally improves the protection afforded the wearer. Passing the Bitrex fit test resulted in 5th percentile SWPFs of 11.1 and 7.9 for elastomeric and filtering-facepiece respirators, respectively. After passing the saccharin tests, the elastomeric respirators provided a 5th percentile of 11.7, and the filtering-facepiece respirators provided a 5th percentile of 11.0. The 5th percentiles after passing the N95-Companion were 13.0 for the elastomeric respirators and 20.5 for the filtering-facepiece respirators. The data supports fit testing as an essential element of a complete respiratory protection program.

  18. Quality issues in blue noise halftoning

    NASA Astrophysics Data System (ADS)

    Yu, Qing; Parker, Kevin J.

    1998-01-01

    The blue noise mask (BNM) is a halftone screen that produces unstructured visually pleasing dot patterns. The BNM combines the blue-noise characteristics of error diffusion and the simplicity of ordered dither. A BNM is constructed by designing a set of interdependent binary patterns for individual gray levels. In this paper, we investigate the quality issues in blue-noise binary pattern design and mask generation as well as in application to color reproduction. Using a global filtering technique and a local 'force' process for rearranging black and white pixels, we are able to generate a series of binary patterns, all representing a certain gray level, ranging from white-noise pattern to highly structured pattern. The quality of these individual patterns are studied in terms of low-frequency structure and graininess. Typically, the low-frequency structure (LF) is identified with a measurement of the energy around dc in the spatial frequency domain, while the graininess is quantified by a measurement of the average minimum distance (AMD) between minority dots as well as the kurtosis of the local kurtosis distribution (KLK) for minority pixels of the binary pattern. A set of partial BNMs are generated by using the different patterns as unique starting 'seeds.' In this way, we are able to study the quality of binary patterns over a range of gray levels. We observe that the optimality of a binary pattern for mask generation is related to its own quality mertirc values as well as the transition smoothness of those quality metric values over neighboring levels. Several schemes have been developed to apply blue-noise halftoning to color reproduction. Different schemes generate halftone patterns with different textures. In a previous paper, a human visual system (HVS) model was used to study the color halftone quality in terms of luminance and chrominance error in CIELAB color space. In this paper, a new series of psycho-visual experiments address the 'preferred' color rendering among four different blue noise halftoning schemes. The experimental results will be interpreted with respect to the proposed halftone quality metrics.

  19. Excitation-based and informational masking of a tonal signal in a four-tone masker.

    PubMed

    Leibold, Lori J; Hitchens, Jack J; Buss, Emily; Neff, Donna L

    2010-04-01

    This study examined contributions of peripheral excitation and informational masking to the variability in masking effectiveness observed across samples of multi-tonal maskers. Detection thresholds were measured for a 1000-Hz signal presented simultaneously with each of 25, four-tone masker samples. Using a two-interval, forced-choice adaptive task, thresholds were measured with each sample fixed throughout trial blocks for ten listeners. Average thresholds differed by as much as 26 dB across samples. An excitation-based model of partial loudness [Moore, B. C. J. et al. (1997). J. Audio Eng. Soc. 45, 224-237] was used to predict thresholds. These predictions accounted for a significant portion of variance in the data of several listeners, but no relation between the model and data was observed for many listeners. Moreover, substantial individual differences, on the order of 41 dB, were observed for some maskers. The largest individual differences were found for maskers predicted to produce minimal excitation-based masking. In subsequent conditions, one of five maskers was randomly presented in each interval. The difference in performance for samples with low versus high predicted thresholds was reduced in random compared to fixed conditions. These findings are consistent with a trading relation whereby informational masking is largest for conditions in which excitation-based masking is smallest.

  20. The Effect of Conventional and Transparent Surgical Masks on Speech Understanding in Individuals with and without Hearing Loss.

    PubMed

    Atcherson, Samuel R; Mendel, Lisa Lucks; Baltimore, Wesley J; Patro, Chhayakanta; Lee, Sungmin; Pousson, Monique; Spann, M Joshua

    2017-01-01

    It is generally well known that speech perception is often improved with integrated audiovisual input whether in quiet or in noise. In many health-care environments, however, conventional surgical masks block visual access to the mouth and obscure other potential facial cues. In addition, these environments can be noisy. Although these masks may not alter the acoustic properties, the presence of noise in addition to the lack of visual input can have a deleterious effect on speech understanding. A transparent ("see-through") surgical mask may help to overcome this issue. To compare the effect of noise and various visual input conditions on speech understanding for listeners with normal hearing (NH) and hearing impairment using different surgical masks. Participants were assigned to one of three groups based on hearing sensitivity in this quasi-experimental, cross-sectional study. A total of 31 adults participated in this study: one talker, ten listeners with NH, ten listeners with moderate sensorineural hearing loss, and ten listeners with severe-to-profound hearing loss. Selected lists from the Connected Speech Test were digitally recorded with and without surgical masks and then presented to the listeners at 65 dB HL in five conditions against a background of four-talker babble (+10 dB SNR): without a mask (auditory only), without a mask (auditory and visual), with a transparent mask (auditory only), with a transparent mask (auditory and visual), and with a paper mask (auditory only). A significant difference was found in the spectral analyses of the speech stimuli with and without the masks; however, no more than ∼2 dB root mean square. Listeners with NH performed consistently well across all conditions. Both groups of listeners with hearing impairment benefitted from visual input from the transparent mask. The magnitude of improvement in speech perception in noise was greatest for the severe-to-profound group. Findings confirm improved speech perception performance in noise for listeners with hearing impairment when visual input is provided using a transparent surgical mask. Most importantly, the use of the transparent mask did not negatively affect speech perception performance in noise. American Academy of Audiology

  1. Diffractive phase-shift lithography photomask operating in proximity printing mode.

    PubMed

    Cirino, Giuseppe A; Mansano, Ronaldo D; Verdonck, Patrick; Cescato, Lucila; Neto, Luiz G

    2010-08-02

    A phase shift proximity printing lithographic mask is designed, manufactured and tested. Its design is based on a Fresnel computer-generated hologram, employing the scalar diffraction theory. The obtained amplitude and phase distributions were mapped into discrete levels. In addition, a coding scheme using sub-cells structure was employed in order to increase the number of discrete levels, thus increasing the degree of freedom in the resulting mask. The mask is fabricated on a fused silica substrate and an amorphous hydrogenated carbon (a:C-H) thin film which act as amplitude modulation agent. The lithographic image is projected onto a resist coated silicon wafer, placed at a distance of 50 microm behind the mask. The results show a improvement of the achieved resolution--linewidth as good as 1.5 microm--what is impossible to obtain with traditional binary masks in proximity printing mode. Such achieved dimensions can be used in the fabrication of MEMS and MOEMS devices. These results are obtained with a UV laser but also with a small arc lamp light source exploring the partial coherence of this source.

  2. Evoked-potential recovery during double click stimulation in a beluga whale: implications for biosonar gain control.

    PubMed

    Supin, Alexander Ya; Popov, Vladimir V

    2015-05-01

    Auditory evoked potentials (AEPs) were recorded in a beluga whale Delphinapterus leucas using a double-pulse stimulation paradigm, specifically measuring the recovery (release from masking) of the second (test) response as a function of delay after the first (conditioning) pulse at various levels of the conditioning and test stimuli. The conditioning/test stimulus level ratio influenced the recovery time (the higher the ratio, the longer the recovery). This interrelation was used to evaluate the intensity/time trade in release from forward masking. Trade was evaluated as 32.2 dB per time decade. Data were considered as simulating interactions between the transmitted pulse and echo during echolocation, assuming that a transmitted sonar pulse produces forward masking of the echo response. With increased target distance, the attenuation of the echo may be compensated by the release from masking. According to the model, the compensation results in substantial stabilization of the echo response even if the intensity/time trade of release from masking is not precisely equal to the rate of echo attenuation with distance.

  3. Simultaneous masking between electric and acoustic stimulation in cochlear implant users with residual low-frequency hearing.

    PubMed

    Krüger, Benjamin; Büchner, Andreas; Nogueira, Waldo

    2017-09-01

    Ipsilateral electric-acoustic stimulation (EAS) is becoming increasingly important in cochlear implant (CI) treatment. Improvements in electrode designs and surgical techniques have contributed to improved hearing preservation during implantation. Consequently, CI implantation criteria have been expanded toward people with significant residual low-frequency hearing, who may benefit from the combined use of both the electric and acoustic stimulation in the same ear. However, only few studies have investigated the mutual interaction between electric and acoustic stimulation modalities. This work characterizes the interaction between both stimulation modalities using psychophysical masking experiments and cone beam computer tomography (CBCT). Two psychophysical experiments for electric and acoustic masking were performed to measure the hearing threshold elevation of a probe stimulus in the presence of a masker stimulus. For electric masking, the probe stimulus was an acoustic tone while the masker stimulus was an electric pulse train. For acoustic masking, the probe stimulus was an electric pulse train and the masker stimulus was an acoustic tone. Five EAS users, implanted with a CI and ipsilateral residual low-frequency hearing, participated in the study. Masking was determined at different electrodes and different acoustic frequencies. CBCT scans were used to determine the individual place-pitch frequencies of the intracochlear electrode contacts by using the Stakhovskaya place-to-frequency transformation. This allows the characterization of masking as a function of the difference between electric and acoustic stimulation sites, which we term the electric-acoustic frequency difference (EAFD). The results demonstrate a significant elevation of detection thresholds for both experiments. In electric masking, acoustic-tone thresholds increased exponentially with decreasing EAFD. In contrast, for the acoustic masking experiment, threshold elevations were present regardless of the tested EAFDs. Based on the present findings, we conclude that there is an asymmetry between the electric and the acoustic masker modalities. These observations have implications for the design and fitting of EAS sound-coding strategies. Copyright © 2017 Elsevier B.V. All rights reserved.

  4. Suppression and Contrast Normalization in Motion Processing

    PubMed Central

    2017-01-01

    Sensory neurons are activated by a range of stimuli to which they are said to be tuned. Usually, they are also suppressed by another set of stimuli that have little effect when presented in isolation. The interactions between preferred and suppressive stimuli are often quite complex and vary across neurons, even within a single area, making it difficult to infer their collective effect on behavioral responses mediated by activity across populations of neurons. Here, we investigated this issue by measuring, in human subjects (three males), the suppressive effect of static masks on the ocular following responses induced by moving stimuli. We found a wide range of effects, which depend in a nonlinear and nonseparable manner on the spatial frequency, contrast, and spatial location of both stimulus and mask. Under some conditions, the presence of the mask can be seen as scaling the contrast of the driving stimulus. Under other conditions, the effect is more complex, involving also a direct scaling of the behavioral response. All of this complexity at the behavioral level can be captured by a simple model in which stimulus and mask interact nonlinearly at two stages, one monocular and one binocular. The nature of the interactions is compatible with those observed at the level of single neurons in primates, usually broadly described as divisive normalization, without having to invoke any scaling mechanism. SIGNIFICANCE STATEMENT The response of sensory neurons to their preferred stimulus is often modulated by stimuli that are not effective when presented alone. Individual neurons can exhibit multiple modulatory effects, with considerable variability across neurons even in a single area. Such diversity has made it difficult to infer the impact of these modulatory mechanisms on behavioral responses. Here, we report the effects of a stationary mask on the reflexive eye movements induced by a moving stimulus. A model with two stages, each incorporating a divisive modulatory mechanism, reproduces our experimental results and suggests that qualitative variability of masking effects in cortical neurons might arise from differences in the extent to which such effects are inherited from earlier stages. PMID:29018158

  5. Evaluation of psychoacoustic tests and P300 event-related potentials in elderly patients with hyperhomocysteinemia.

    PubMed

    Díaz-Leines, Sergio; Peñaloza-López, Yolanda R; Serrano-Miranda, Tirzo A; Flores-Ávalos, Blanca; Vidal-Ixta, Martha T; Jiménez-Herrera, Blanca

    2013-01-01

    Hyperhomocysteinemia as a risk factor for hearing impairment, neuronal damage and cognitive impairment in elderly patients is controversial and is limited by the small number of studies. The aim of this work was determine if elderly patients detected with hyperhomocysteinemia have an increased risk of developing abnormalities in the central auditory processes as compared with a group of patients with appropriate homocysteine levels, and to define the behaviour of psychoacoustic tests and long latency potentials (P300) in these patients. This was a cross-sectional, comparative and analytical study. We formed a group of patients with hyperhomocysteinemia and a control group with normal levels of homocysteine. All patients underwent audiometry, tympanometry and a selection of psychoacoustic tests (dichotic digits, low-pass filtered words, speech in noise and masking level difference), auditory evoked brainstem potentials and P300. Patients with hyperhomocysteinemia had higher values in the test of masking level difference than did the control group (P=.049) and more protracted latency in P300 (P=.000). Hyperhomocysteinemia is a factor that alters the central auditory functions. Alterations in psychoacoustic tests and disturbances in electrophysiological tests suggest that the central portion of the auditory pathway is affected in patients with hyperhomocysteinemia. Copyright © 2012 Elsevier España, S.L. All rights reserved.

  6. The neural processing of masked speech

    PubMed Central

    Scott, Sophie K; McGettigan, Carolyn

    2014-01-01

    Spoken language is rarely heard in silence, and a great deal of interest in psychoacoustics has focused on the ways that the perception of speech is affected by properties of masking noise. In this review we first briefly outline the neuroanatomy of speech perception. We then summarise the neurobiological aspects of the perception of masked speech, and investigate this as a function of masker type, masker level and task. PMID:23685149

  7. Apparent source levels and active communication space of whistles of free-ranging Indo-Pacific humpback dolphins (Sousa chinensis) in the Pearl River Estuary and Beibu Gulf, China

    PubMed Central

    Wang, Zhi-Tao; W.L. Au, Whitlow; Rendell, Luke; Wu, Hai-Ping; Wu, Yu-Ping; Liu, Jian-Chang; Duan, Guo-Qin; Cao, Han-Jiang

    2016-01-01

    Background. Knowledge of species-specific vocalization characteristics and their associated active communication space, the effective range over which a communication signal can be detected by a conspecific, is critical for understanding the impacts of underwater acoustic pollution, as well as other threats. Methods. We used a two-dimensional cross-shaped hydrophone array system to record the whistles of free-ranging Indo-Pacific humpback dolphins (Sousa chinensis) in shallow-water environments of the Pearl River Estuary (PRE) and Beibu Gulf (BG), China. Using hyperbolic position fixing, which exploits time differences of arrival of a signal between pairs of hydrophone receivers, we obtained source location estimates for whistles with good signal-to-noise ratio (SNR ≥10 dB) and not polluted by other sounds and back-calculated their apparent source levels (ASL). Combining with the masking levels (including simultaneous noise levels, masking tonal threshold, and the Sousa auditory threshold) and the custom made site-specific sound propagation models, we further estimated their active communication space (ACS). Results. Humpback dolphins produced whistles with average root-mean-square ASL of 138.5 ± 6.8 (mean ± standard deviation) and 137.2 ± 7.0 dB re 1 µPa in PRE (N = 33) and BG (N = 209), respectively. We found statistically significant differences in ASLs among different whistle contour types. The mean and maximum ACS of whistles were estimated to be 14.7 ± 2.6 (median ± quartile deviation) and 17.1± 3.5 m in PRE, and 34.2 ± 9.5 and 43.5 ± 12.2 m in BG. Using just the auditory threshold as the masking level produced the mean and maximum ACSat of 24.3 ± 4.8 and 35.7 ± 4.6 m for PRE, and 60.7 ± 18.1 and 74.3 ± 25.3 m for BG. The small ACSs were due to the high ambient noise level. Significant differences in ACSs were also observed among different whistle contour types. Discussion. Besides shedding some light for evaluating appropriate noise exposure levels and information for the regulation of underwater acoustic pollution, these baseline data can also be used for aiding the passive acoustic monitoring of dolphin populations, defining the boundaries of separate groups in a more biologically meaningful way during field surveys, and guiding the appropriate approach distance for local dolphin-watching boats and research boat during focal group following. PMID:26893973

  8. Apparent source levels and active communication space of whistles of free-ranging Indo-Pacific humpback dolphins (Sousa chinensis) in the Pearl River Estuary and Beibu Gulf, China.

    PubMed

    Wang, Zhi-Tao; W L Au, Whitlow; Rendell, Luke; Wang, Ke-Xiong; Wu, Hai-Ping; Wu, Yu-Ping; Liu, Jian-Chang; Duan, Guo-Qin; Cao, Han-Jiang; Wang, Ding

    2016-01-01

    Background. Knowledge of species-specific vocalization characteristics and their associated active communication space, the effective range over which a communication signal can be detected by a conspecific, is critical for understanding the impacts of underwater acoustic pollution, as well as other threats. Methods. We used a two-dimensional cross-shaped hydrophone array system to record the whistles of free-ranging Indo-Pacific humpback dolphins (Sousa chinensis) in shallow-water environments of the Pearl River Estuary (PRE) and Beibu Gulf (BG), China. Using hyperbolic position fixing, which exploits time differences of arrival of a signal between pairs of hydrophone receivers, we obtained source location estimates for whistles with good signal-to-noise ratio (SNR ≥10 dB) and not polluted by other sounds and back-calculated their apparent source levels (ASL). Combining with the masking levels (including simultaneous noise levels, masking tonal threshold, and the Sousa auditory threshold) and the custom made site-specific sound propagation models, we further estimated their active communication space (ACS). Results. Humpback dolphins produced whistles with average root-mean-square ASL of 138.5 ± 6.8 (mean ± standard deviation) and 137.2 ± 7.0 dB re 1 µPa in PRE (N = 33) and BG (N = 209), respectively. We found statistically significant differences in ASLs among different whistle contour types. The mean and maximum ACS of whistles were estimated to be 14.7 ± 2.6 (median ± quartile deviation) and 17.1± 3.5 m in PRE, and 34.2 ± 9.5 and 43.5 ± 12.2 m in BG. Using just the auditory threshold as the masking level produced the mean and maximum ACSat of 24.3 ± 4.8 and 35.7 ± 4.6 m for PRE, and 60.7 ± 18.1 and 74.3 ± 25.3 m for BG. The small ACSs were due to the high ambient noise level. Significant differences in ACSs were also observed among different whistle contour types. Discussion. Besides shedding some light for evaluating appropriate noise exposure levels and information for the regulation of underwater acoustic pollution, these baseline data can also be used for aiding the passive acoustic monitoring of dolphin populations, defining the boundaries of separate groups in a more biologically meaningful way during field surveys, and guiding the appropriate approach distance for local dolphin-watching boats and research boat during focal group following.

  9. Fabrication of coronagraph masks and laboratory scale star-shade masks: characteristics, defects, and performance

    NASA Astrophysics Data System (ADS)

    Balasubramanian, Kunjithapatham; Riggs, A. J. Eldorado; Cady, Eric; White, Victor; Yee, Karl; Wilson, Daniel; Echternach, Pierre; Muller, Richard; Mejia Prada, Camilo; Seo, Byoung-Joon; Shi, Fang; Ryan, Daniel; Fregoso, Santos; Metzman, Jacob; Wilson, Robert Casey

    2017-09-01

    NASA WFIRST mission has planned to include a coronagraph instrument to find and characterize exoplanets. Masks are needed to suppress the host star light to better than 10-8 - 10-9 level contrast over a broad bandwidth to enable the coronagraph mission objectives. Such masks for high contrast coronagraphic imaging require various fabrication technologies to meet a wide range of specifications, including precise shapes, micron scale island features, ultra-low reflectivity regions, uniformity, wave front quality, etc. We present the technologies employed at JPL to produce these pupil plane and image plane coronagraph masks, and lab-scale external occulter masks, highlighting accomplishments from the high contrast imaging testbed (HCIT) at JPL and from the high contrast imaging lab (HCIL) at Princeton University. Inherent systematic and random errors in fabrication and their impact on coronagraph performance are discussed with model predictions and measurements.

  10. Understanding EUV mask blank surface roughness induced LWR and associated roughness requirement

    NASA Astrophysics Data System (ADS)

    Yan, Pei-Yang; Zhang, Guojing; Gullikson, Eric M.; Goldberg, Ken A.; Benk, Markus P.

    2015-03-01

    Extreme ultraviolet lithography (EUVL) mask multi-layer (ML) blank surface roughness specification historically comes from blank defect inspection tool requirement. Later, new concerns on ML surface roughness induced wafer pattern line width roughness (LWR) arise. In this paper, we have studied wafer level pattern LWR as a function of EUVL mask surface roughness via High-NA Actinic Reticle Review Tool. We found that the blank surface roughness induced LWR at current blank roughness level is in the order of 0.5nm 3σ for NA=0.42 at the best focus. At defocus of ±40nm, the corresponding LWR will be 0.2nm higher. Further reducing EUVL mask blank surface roughness will increase the blank cost with limited benefit in improving the pattern LWR, provided that the intrinsic resist LWR is in the order of 1nm and above.

  11. Speech-on-speech masking with variable access to the linguistic content of the masker speech for native and nonnative english speakers.

    PubMed

    Calandruccio, Lauren; Bradlow, Ann R; Dhar, Sumitrajit

    2014-04-01

    Masking release for an English sentence-recognition task in the presence of foreign-accented English speech compared with native-accented English speech was reported in Calandruccio et al (2010a). The masking release appeared to increase as the masker intelligibility decreased. However, it could not be ruled out that spectral differences between the speech maskers were influencing the significant differences observed. The purpose of the current experiment was to minimize spectral differences between speech maskers to determine how various amounts of linguistic information within competing speech Affiliationect masking release. A mixed-model design with within-subject (four two-talker speech maskers) and between-subject (listener group) factors was conducted. Speech maskers included native-accented English speech and high-intelligibility, moderate-intelligibility, and low-intelligibility Mandarin-accented English. Normalizing the long-term average speech spectra of the maskers to each other minimized spectral differences between the masker conditions. Three listener groups were tested, including monolingual English speakers with normal hearing, nonnative English speakers with normal hearing, and monolingual English speakers with hearing loss. The nonnative English speakers were from various native language backgrounds, not including Mandarin (or any other Chinese dialect). Listeners with hearing loss had symmetric mild sloping to moderate sensorineural hearing loss. Listeners were asked to repeat back sentences that were presented in the presence of four different two-talker speech maskers. Responses were scored based on the key words within the sentences (100 key words per masker condition). A mixed-model regression analysis was used to analyze the difference in performance scores between the masker conditions and listener groups. Monolingual English speakers with normal hearing benefited when the competing speech signal was foreign accented compared with native accented, allowing for improved speech recognition. Various levels of intelligibility across the foreign-accented speech maskers did not influence results. Neither the nonnative English-speaking listeners with normal hearing nor the monolingual English speakers with hearing loss benefited from masking release when the masker was changed from native-accented to foreign-accented English. Slight modifications between the target and the masker speech allowed monolingual English speakers with normal hearing to improve their recognition of native-accented English, even when the competing speech was highly intelligible. Further research is needed to determine which modifications within the competing speech signal caused the Mandarin-accented English to be less effective with respect to masking. Determining the influences within the competing speech that make it less effective as a masker or determining why monolingual normal-hearing listeners can take advantage of these differences could help improve speech recognition for those with hearing loss in the future. American Academy of Audiology.

  12. Masking of thresholds for the perception of fore-and-aft vibration of seat backrests.

    PubMed

    Morioka, Miyuki; Griffin, Michael J

    2015-09-01

    The detection of a vibration may be reduced by the presence of another vibration: a phenomenon known as 'masking'. This study investigated how the detection of one frequency of vibration is influenced by vibration at another frequency. With nine subjects, thresholds for detecting fore-and-aft backrest vibration were determined (for 4, 8, 16, and 31.5-Hz sinusoidal vibration) in the presence of a masker vibration (4-Hz random vibration, 1/3-octave bandwidth at six intensities). The masker vibration increased thresholds for perceiving vibration at each frequency by an amount that reduced with increasing difference between the frequency of the sinusoidal vibration and the frequency of the masker vibration. The 4-Hz random vibration almost completely masked 4-Hz sinusoidal vibration, partially masked 8- and 16-Hz vibration, and only slightly masked 31.5-Hz vibration. The findings might be explained by the involvement of different sensory systems and different body locations in the detection of different frequencies of vibration. Copyright © 2015 Elsevier Ltd and The Ergonomics Society. All rights reserved.

  13. Development of Personalized Fitting Device With 3-Dimensional Solution for Prevention of NIV Oronasal Mask-Related Pressure Ulcers.

    PubMed

    Shikama, Maiko; Nakagami, Gojiro; Noguchi, Hiroshi; Mori, Taketoshi; Sanada, Hiromi

    2018-05-22

    Pressure ulcers related to oronasal masks used with noninvasive ventilation (NIV), along with patient discomfort, occur due to improper fit of the mask. We developed a personalized fitting device using a 3-dimensional (3D) scanning solution to prevent the formation of NIV mask-related pressure ulcers. This study aimed to evaluate the effectiveness of the proposed personalized fitting device. We conducted a randomized crossover experimental study of 20 healthy participants to study the use of this personalized fitting device between the face and an NIV mask designed with 3D solutions. The fitting device was not used under the NIV mask for the control. The outcome measures were the presence of blanchable erythema, standardized redness intensity, discomfort level, and contact pressure. The incidence of blanchable erythema and standardized redness intensity values were significantly lower for subjects who used the fitting device when worn for 30 min ( P < .001). The discomfort levels at the forehead, nasal bridge, and both cheeks, as well as leakage, were significantly reduced as well ( P = .008, P < .001, P = .001, P = .002, P = .001, P = .02, P < .001, P < .001, P < .001). Contact pressure at the nasal bridge, where pressure ulcers most frequently develop, was significantly decreased with the fitting device ( P < .001). Personalized fitting devices that incorporate 3D scanning solutions may contribute to the prevention of NIV mask-related pressure ulcers and the reduction of discomfort. Copyright © 2018 by Daedalus Enterprises.

  14. Design criteria for small coded aperture masks in gamma-ray astronomy

    NASA Technical Reports Server (NTRS)

    Sembay, S.; Gehrels, Neil

    1990-01-01

    Most theoretical work on coded aperture masks in X-ray and low-energy gamma-ray astronomy has concentrated on masks with large numbers of elements. For gamma-ray spectrometers in the MeV range, the detector plane usually has only a few discrete elements, so that masks with small numbers of elements are called for. For this case it is feasible to analyze by computer all the possible mask patterns of given dimension to find the ones that best satisfy the desired performance criteria. A particular set of performance criteria for comparing the flux sensitivities, source positioning accuracies and transparencies of different mask patterns is developed. The results of such a computer analysis for masks up to dimension 5 x 5 unit cell are presented and it is concluded that there is a great deal of flexibility in the choice of mask pattern for each dimension.

  15. Optical proximity correction for anamorphic extreme ultraviolet lithography

    NASA Astrophysics Data System (ADS)

    Clifford, Chris; Lam, Michael; Raghunathan, Ananthan; Jiang, Fan; Fenger, Germain; Adam, Kostas

    2017-10-01

    The change from isomorphic to anamorphic optics in high numerical aperture (NA) extreme ultraviolet (EUV) scanners necessitates changes to the mask data preparation flow. The required changes for each step in the mask tape out process are discussed, with a focus on optical proximity correction (OPC). When necessary, solutions to new problems are demonstrated, and verified by rigorous simulation. Additions to the OPC model include accounting for anamorphic effects in the optics, mask electromagnetics, and mask manufacturing. The correction algorithm is updated to include awareness of anamorphic mask geometry for mask rule checking (MRC). OPC verification through process window conditions is enhanced to test different wafer scale mask error ranges in the horizontal and vertical directions. This work will show that existing models and methods can be updated to support anamorphic optics without major changes. Also, the larger mask size in the Y direction can result in better model accuracy, easier OPC convergence, and designs which are more tolerant to mask errors.

  16. Neural Correlates of the Binaural Masking Level Difference in Human Frequency-Following Responses.

    PubMed

    Clinard, Christopher G; Hodgson, Sarah L; Scherer, Mary Ellen

    2017-04-01

    The binaural masking level difference (BMLD) is an auditory phenomenon where binaural tone-in-noise detection is improved when the phase of either signal or noise is inverted in one of the ears (S π N o or S o N π , respectively), relative to detection when signal and noise are in identical phase at each ear (S o N o ). Processing related to BMLDs and interaural time differences has been confirmed in the auditory brainstem of non-human mammals; in the human auditory brainstem, phase-locked neural responses elicited by BMLD stimuli have not been systematically examined across signal-to-noise ratio. Behavioral and physiological testing was performed in three binaural stimulus conditions: S o N o , S π N o , and S o N π . BMLDs at 500 Hz were obtained from 14 young, normal-hearing adults (ages 21-26). Physiological BMLDs used the frequency-following response (FFR), a scalp-recorded auditory evoked potential dependent on sustained phase-locked neural activity; FFR tone-in-noise detection thresholds were used to calculate physiological BMLDs. FFR BMLDs were significantly smaller (poorer) than behavioral BMLDs, and FFR BMLDs did not reflect a physiological release from masking, on average. Raw FFR amplitude showed substantial reductions in the S π N o condition relative to S o N o and S o N π conditions, consistent with negative effects of phase summation from left and right ear FFRs. FFR amplitude differences between stimulus conditions (e.g., S o N o amplitude-S π N o amplitude) were significantly predictive of behavioral S π N o BMLDs; individuals with larger amplitude differences had larger (better) behavioral B MLDs and individuals with smaller amplitude differences had smaller (poorer) behavioral B MLDs. These data indicate a role for sustained phase-locked neural activity in BMLDs of humans and are the first to show predictive relationships between behavioral BMLDs and human brainstem responses.

  17. Masked priming effect reflects evidence accumulated by the prime.

    PubMed

    Kinoshita, Sachiko; Norris, Dennis

    2010-01-01

    In the same-different match task, masked priming is observed with the same responses but not different responses. Norris and Kinoshita's (2008) Bayesian reader account of masked priming explains this pattern based on the same principle as that explaining the absence of priming for nonwords in the lexical decision task. The pattern of priming follows from the way the model makes optimal decisions in the two tasks; priming does not depend on first activating the prime and then the target. An alternative explanation is in terms of a bias towards responding "same" that exactly counters the facilitatory effect of lexical access. The present study tested these two views by varying both the degree to which the prime predicts the response and the visibility of the prime. Unmasked primes produced effects expected from the view that priming is influenced by the degree to which the prime predicts the response. In contrast, with masked primes, the size of priming for the same response was completely unaffected by predictability. These results rule out response bias as an explanation of the absence of masked priming for different responses and, in turn, indicate that masked priming is not a consequence of automatic lexical access of the prime.

  18. Sex differences in associations between cannabis craving and neural responses to cannabis cues: Implications for treatment.

    PubMed

    Wetherill, Reagan R; Jagannathan, Kanchana; Hager, Nathan; Childress, Anna Rose; Franklin, Teresa R

    2015-08-01

    Preclinical and clinical research indicates that there are sex differences in how men and women initiate, progress, respond to, and withdraw from cannabis use; however, neurophysiological differences, such as neural responses to cannabis cues, are not well understood. Using functional MRI and an event-related blood oxygen level-dependent backward-masking task, we compared neural responses to backward-masked cannabis cues to neutral cues in treatment-seeking, cannabis-dependent adults (N = 44; 27 males) and examined whether sex differences exist. In addition, functional MRI findings were correlated with cannabis craving. Backward-masked cannabis cues elicited greater neural responses than neutral cues in reward-related brain regions, including the striatum, hippocampus/amygdala, insula, anterior cingulate cortex, and lateral orbitofrontal cortex, p < .01, k > 121 voxels. Although no significant sex differences in neural responses to cannabis cues emerged, women showed a positive correlation between neural responses to cannabis cues in the bilateral insula and cannabis craving and an inverse correlation between neural responses to cannabis cues in the left lateral orbitofrontal cortex and cannabis craving. Men, however, showed a positive correlation between neural responses to cannabis cues in the striatum and cannabis craving. Given that cues and craving are important triggers and the focus on many behavioral treatment approaches, these findings suggest that treatment-seeking, cannabis-dependent men and women may benefit from sex-specific and tailored cannabis use disorder treatments. (c) 2015 APA, all rights reserved).

  19. Atypical parietal lobe activity to subliminal faces in youth with a family history of alcoholism

    PubMed Central

    Peraza, Jennifer; Cservenka, Anita; Herting, Megan M.; Nagel, Bonnie J.

    2015-01-01

    Background Adults with alcohol use disorders (AUDs) show different behavioral and neurological functioning during emotional processing tasks from healthy controls. Adults with a family history (FHP) of AUD also show different activation in limbic brain areas, such as the amygdala. However, it is unclear if this pattern exists during adolescence before any episodes of heavy alcohol use. Objectives We hypothesized that the amygdalar response to subliminally-presented fearful faces would be reduced in FHP adolescents compared to peers who were family history negative (FHN) for AUD. Method An adapted Masked Faces paradigm was used to examine blood oxygen level-dependent response to subliminal fearful vs. neutral faces in 14 FHP (6 females, 8 males) and 15 FHN (6 females, 9 males) youth, ages 11–15 years. Both FHP and FHN youth had no history of heavy alcohol consumption. Results A significant difference was seen between groups in the left superior parietal lobule FHN youth showed deactivation to fearful and neutral masked faces compared to baseline, whereas FHP youth showed deactivation only to fearful masked faces. No significant differences in amygdalar activation were seen between groups. Conclusion The left superior parietal lobule is part of the fronto-parietal network, which has been implicated in attentional control. Lack of reduced neural activity to neutral faces among FHP youth may represent differences in suppressing attention networks to less salient emotional stimuli, or perhaps, a higher threshold of saliency for emotional stimuli among at-risk youth. PMID:25268683

  20. Atypical parietal lobe activity to subliminal faces in youth with a family history of alcoholism.

    PubMed

    Peraza, Jennifer; Cservenka, Anita; Herting, Megan M; Nagel, Bonnie J

    2015-03-01

    Adults with alcohol use disorders (AUDs) show different behavioral and neurological functioning during emotional processing tasks from healthy controls. Adults with a family history (FHP) of AUD also show different activation in limbic brain areas, such as the amygdala. However, it is unclear if this pattern exists during adolescence before any episodes of heavy alcohol use. We hypothesized that the amygdalar response to subliminally-presented fearful faces would be reduced in FHP adolescents compared to peers who were family history negative (FHN) for AUD. An adapted Masked Faces paradigm was used to examine blood oxygen level-dependent response to subliminal fearful vs. neutral faces in 14 FHP (6 females, 8 males) and 15 FHN (6 females, 9 males) youth, ages 11-15 years. Both FHP and FHN youth had no history of heavy alcohol consumption. A significant difference was seen between groups in the left superior parietal lobule FHN youth showed deactivation to fearful and neutral masked faces compared to baseline, whereas FHP youth showed deactivation only to fearful masked faces. No significant differences in amygdalar activation were seen between groups. The left superior parietal lobule is part of the fronto-parietal network, which has been implicated in attentional control. Lack of reduced neural activity to neutral faces among FHP youth may represent differences in suppressing attention networks to less salient emotional stimuli, or perhaps, a higher threshold of saliency for emotional stimuli among at-risk youth.

  1. Green clay and aloe vera peel-off facial masks: response surface methodology applied to the formulation design.

    PubMed

    O'Reilly Beringhs, André; Rosa, Julia Macedo; Stulzer, Hellen Karine; Budal, Rosane Maria; Sonaglio, Diva

    2013-03-01

    This article describes the optimization of a peel-off facial mask formulation. An investigation was carried out on the parameters of the formulation that most affect the desirable characteristics of peel-off facial masks. Cereal alcohol had a significant effect on the drying time at concentrations of 1-12% (w/w). The applicability of the evaluated formulations was influenced by both carbomer (0-2.4%; w/w) and polyvinyl alcohol (PVA; 2.5-17.5%; w/w) content due to their ability to alter the formulation viscosity. Inverse concentrations of carbomer and PVA led to formulations with optimum viscosity for facial application. Film-forming performance was influenced only by the PVA concentration, achieving maximum levels at concentrations of around 11% (w/w). The optimized formulation, determined mathematically, contained 13% (w/w) PVA and 10% (w/w) cereal alcohol with no addition of carbomer. This formulation provided high levels of applicability and film-forming performance, the lowest drying time possible and excellent homogeneity of the green clay particles and aloe vera before and after drying. The preliminary stability study indicated that the optimized formulation is stable under normal storage conditions. The microbiological stability evaluation indicated that the preservative was efficient in terms of avoiding microbial growth. RSM was shown to be a useful statistical tool for the determination of the behavior of different compounds and their concentrations for the responses studied, allowing the investigation of the optimum conditions for the production of green clay and aloe vera peel-off facial masks.

  2. Comparing the Efficacy, Mask Leak, Patient Adherence, and Patient Preference of Three Different CPAP Interfaces to Treat Moderate-Severe Obstructive Sleep Apnea.

    PubMed

    Rowland, Sharn; Aiyappan, Vinod; Hennessy, Cathy; Catcheside, Peter; Chai-Coezter, Ching Li; McEvoy, R Doug; Antic, Nick A

    2018-01-15

    To determine if the type of continuous positive airway pressure (CPAP) mask interface influences CPAP treatment efficacy, adherence, side effects, comfort and sleep quality in patients with moderate-severe obstructive sleep apnea (OSA). This took place in a hospital-based tertiary sleep disorders unit. It is a prospective, randomized, crossover trial comparing three CPAP interfaces: nasal mask (NM), nasal mask plus chinstrap (NM-CS) and oronasal mask (ONM) each tried in random order, for 4 weeks. After each 4-week period, patient outcomes were assessed. Participants had a new diagnosis of obstructive sleep apneas. Forty-eight patients with moderate-severe OSA (32 males, mean ± standard deviation apnea-hypopnea index (AHI) 55.6 ± 21.1 events/h, age 54.9 ± 13.1 years, body mass index 35.8 ± 7.2 kg/m 2 ) were randomized. Thirty-five participants completed the full study, with complete data available for 34 patients. There was no statistically significant difference in CPAP adherence; however, residual AHI was higher with ONM than NM and NM-CS (residual AHI 7.1 ± 7.7, 4.0 ± 3.1, 4.2 ± 3.7 events/h respectively, main effect P = .001). Patient satisfaction and quality of sleep were higher with the NM and NM-CS than the ONM. Fewer leak and mask fit problems were reported with NM (all chi-square P < .05), which patients preferred over the NM-CS and ONM options (n = 22, 9 and 4 respectively, P = .001). The CPAP adherence did not differ between the three different mask interfaces but the residual AHI was lower with NM than ONM and patients reported greater mask comfort, better sleep, and overall preference for a NM. A nasal mask with or without chinstrap should be the first choice for patients with OSA referred for CPAP treatment. Registry: Australian and New Zealand Clinical Trials Registry, URL: https://www.anzctr.org.au, title: A comparison of continuous positive airway pressure (CPAP) interface in the control of leak, patient compliance and patient preference: nasal CPAP mask and chinstrap versus full face mask in patients with obstructive sleep apnoea (OSA), identifier: ACTRN12609000029291. © 2018 American Academy of Sleep Medicine

  3. Adaptation to different noninvasive ventilation masks in critically ill patients*

    PubMed Central

    da Silva, Renata Matos; Timenetsky, Karina Tavares; Neves, Renata Cristina Miranda; Shigemichi, Liane Hirano; Kanda, Sandra Sayuri; Maekawa, Carla; Silva, Eliezer; Eid, Raquel Afonso Caserta

    2013-01-01

    OBJECTIVE: To identify which noninvasive ventilation (NIV) masks are most commonly used and the problems related to the adaptation to such masks in critically ill patients admitted to a hospital in the city of São Paulo, Brazil. METHODS: An observational study involving patients ≥ 18 years of age admitted to intensive care units and submitted to NIV. The reason for NIV use, type of mask, NIV regimen, adaptation to the mask, and reasons for non-adaptation to the mask were investigated. RESULTS: We evaluated 245 patients, with a median age of 82 years. Acute respiratory failure was the most common reason for NIV use (in 71.3%). Total face masks were the most commonly used (in 74.7%), followed by full face masks and near-total face masks (in 24.5% and 0.8%, respectively). Intermittent NIV was used in 82.4% of the patients. Adequate adaptation to the mask was found in 76% of the patients. Masks had to be replaced by another type of mask in 24% of the patients. Adequate adaptation to total face masks and full face masks was found in 75.5% and 80.0% of the patients, respectively. Non-adaptation occurred in the 2 patients using near-total facial masks. The most common reason for non-adaptation was the shape of the face, in 30.5% of the patients. CONCLUSIONS: In our sample, acute respiratory failure was the most common reason for NIV use, and total face masks were the most commonly used. The most common reason for non-adaptation to the mask was the shape of the face, which was resolved by changing the type of mask employed. PMID:24068269

  4. Adaptation to different noninvasive ventilation masks in critically ill patients.

    PubMed

    Silva, Renata Matos da; Timenetsky, Karina Tavares; Neves, Renata Cristina Miranda; Shigemichi, Liane Hirano; Kanda, Sandra Sayuri; Maekawa, Carla; Silva, Eliezer; Eid, Raquel Afonso Caserta

    2013-01-01

    To identify which noninvasive ventilation (NIV) masks are most commonly used and the problems related to the adaptation to such masks in critically ill patients admitted to a hospital in the city of São Paulo, Brazil. An observational study involving patients ≥ 18 years of age admitted to intensive care units and submitted to NIV. The reason for NIV use, type of mask, NIV regimen, adaptation to the mask, and reasons for non-adaptation to the mask were investigated. We evaluated 245 patients, with a median age of 82 years. Acute respiratory failure was the most common reason for NIV use (in 71.3%). Total face masks were the most commonly used (in 74.7%), followed by full face masks and near-total face masks (in 24.5% and 0.8%, respectively). Intermittent NIV was used in 82.4% of the patients. Adequate adaptation to the mask was found in 76% of the patients. Masks had to be replaced by another type of mask in 24% of the patients. Adequate adaptation to total face masks and full face masks was found in 75.5% and 80.0% of the patients, respectively. Non-adaptation occurred in the 2 patients using near-total facial masks. The most common reason for non-adaptation was the shape of the face, in 30.5% of the patients. In our sample, acute respiratory failure was the most common reason for NIV use, and total face masks were the most commonly used. The most common reason for non-adaptation to the mask was the shape of the face, which was resolved by changing the type of mask employed.

  5. Summation versus suppression in metacontrast masking: On the potential pitfalls of using metacontrast masking to assess perceptual-motor dissociation.

    PubMed

    Cardoso-Leite, Pedro; Waszak, Florian

    2014-07-01

    A briefly flashed target stimulus can become "invisible" when immediately followed by a mask-a phenomenon known as backward masking, which constitutes a major tool in the cognitive sciences. One form of backward masking is termed metacontrast masking. It is generally assumed that in metacontrast masking, the mask suppresses activity on which the conscious perception of the target relies. This assumption biases conclusions when masking is used as a tool-for example, to study the independence between perceptual detection and motor reaction. This is because other models can account for reduced perceptual performance without requiring suppression mechanisms. In this study, we used signal detection theory to test the suppression model against an alternative view of metacontrast masking, referred to as the summation model. This model claims that target- and mask-related activations fuse and that the difficulty in detecting the target results from the difficulty to discriminate this fused response from the response produced by the mask alone. Our data support this alternative view. This study is not a thorough investigation of metacontrast masking. Instead, we wanted to point out that when a different model is used to account for the reduced perceptual performance in metacontrast masking, there is no need to postulate a dissociation between perceptual and motor responses to account for the data. Metacontrast masking, as implemented in the Fehrer-Raab situation, therefore is not a valid method to assess perceptual-motor dissociations.

  6. Signal-to-Noise Ratio in Physical Education Settings

    ERIC Educational Resources Information Center

    Ryan, Stu; Grube, Dan; Mokgwathi, Martin M.

    2010-01-01

    It is generally known that in educational settings, excessive noise masks what the teacher is saying; thus, and for maximum learning to occur, the teacher's voice must be highly intelligible to all children (Crandell, Smaldino, & Flexer, 1995). The difference between what the teacher is saying (signal) and the classroom noise level is commonly…

  7. Cognitive Development Masks Support for Attributional Style Models of Depression in Children and Adolescents

    ERIC Educational Resources Information Center

    Weitlauf, Amy S.; Cole, David A.

    2012-01-01

    Attributional style models of depression in adults (Abramson et al. 1989, 1978) have been adapted for use with children; however, most applications do not consider that children's understanding of causal relations may be qualitatively different from that of adults. If children's causal attributions depend on children's level of cognitive…

  8. Particle Size-Selective Assessment of Protection of European Standard FFP Respirators and Surgical Masks against Particles-Tested with Human Subjects

    PubMed Central

    Hwang, Dong-Chir; Li, He-Yi; Tsai, Chieh-Fu; Chen, Chun-Wan; Chen, Jen-Kun

    2016-01-01

    This study was conducted to investigate the protection of disposable filtering half-facepiece respirators of different grades against particles between 0.093 and 1.61 μm. A personal sampling system was used to particle size-selectively assess the protection of respirators. The results show that about 10.9% of FFP2 respirators and 28.2% of FFP3 respirators demonstrate assigned protection factors (APFs) below 10 and 20, which are the levels assigned for these respirators by the British Standard. On average, the protection factors of FFP respirators were 11.5 to 15.9 times greater than those of surgical masks. The minimum protection factors (PFs) were observed for particles between 0.263 and 0.384 μm. No significant difference in PF results was found among FFP respirator categories and particle size. A strong association between fit factors and protection factors was found. The study indicates that FFP respirators may not achieve the expected protection level and the APFs may need to be revised for these classes of respirators. PMID:27195721

  9. Insole-pressure distribution for normal children in different age groups.

    PubMed

    Liu, Xue-Cheng; Lyon, Roger; Thometz, John G; Curtin, Brian; Tarima, Serge; Tassone, Channing

    2011-09-01

    In measuring plantar pressures during gait, earlier methods have used a platform system that does not take into account the interactions feet have with orthotics and shoe wearing. The purpose of the study was to provide normal insole plantar pressure parameter data during stance phase using the Pedar pressure insole system. Twenty-nine normal children, age 6 to 16 years, were recruited and walked along the 25 m walkway at self-selected speeds. Patients were divided into 2 separate groups for statistical analysis--juniors (< 12 y old) and teenagers (> 13 y old). The pressure map was divided into 8 regions (masks) determined by anatomic landmarks and a total of 7 pressure parameters were analyzed of each mask. We did not detect significant differences in foot pressures between juniors and teenagers when regarding sex, or left and right feet for 7 parameters measured. This normative data will provide a basis with which to more accurately assess pediatric pathologic foot deformities and to distinguish dynamic foot deformities from anatomic foot deformities. THE LEVEL OF EVIDENCE: Level II.

  10. Hyper-realistic face masks: a new challenge in person identification.

    PubMed

    Sanders, Jet Gabrielle; Ueda, Yoshiyuki; Minemoto, Kazusa; Noyes, Eilidh; Yoshikawa, Sakiko; Jenkins, Rob

    2017-01-01

    We often identify people using face images. This is true in occupational settings such as passport control as well as in everyday social environments. Mapping between images and identities assumes that facial appearance is stable within certain bounds. For example, a person's apparent age, gender and ethnicity change slowly, if at all. It also assumes that deliberate changes beyond these bounds (i.e., disguises) would be easy to spot. Hyper-realistic face masks overturn these assumptions by allowing the wearer to look like an entirely different person. If unnoticed, these masks break the link between facial appearance and personal identity, with clear implications for applied face recognition. However, to date, no one has assessed the realism of these masks, or specified conditions under which they may be accepted as real faces. Herein, we examined incidental detection of unexpected but attended hyper-realistic masks in both photographic and live presentations. Experiment 1 (UK; n = 60) revealed no evidence for overt detection of hyper-realistic masks among real face photos, and little evidence of covert detection. Experiment 2 (Japan; n = 60) extended these findings to different masks, mask-wearers and participant pools. In Experiment 3 (UK and Japan; n = 407), passers-by failed to notice that a live confederate was wearing a hyper-realistic mask and showed limited evidence of covert detection, even at close viewing distance (5 vs. 20 m). Across all of these studies, viewers accepted hyper-realistic masks as real faces. Specific countermeasures will be required if detection rates are to be improved.

  11. Vector scattering analysis of TPF coronagraph pupil masks

    NASA Astrophysics Data System (ADS)

    Ceperley, Daniel P.; Neureuther, Andrew R.; Lieber, Michael D.; Kasdin, N. Jeremy; Shih, Ta-Ming

    2004-10-01

    Rigorous finite-difference time-domain electromagnetic simulation is used to simulate the scattering from proto-typical pupil mask cross-section geometries and to quantify the differences from the normally assumed ideal on-off behavior. Shaped pupil plane masks are a promising technology for the TPF coronagraph mission. However the stringent requirements placed on the optics require that the detailed behavior of the edge-effects of these masks be examined carefully. End-to-end optical system simulation is essential and an important aspect is the polarization and cross-section dependent edge-effects which are the subject of this paper. Pupil plane masks are similar in many respects to photomasks used in the integrated circuit industry. Simulation capabilities such as the FDTD simulator, TEMPEST, developed for analyzing polarization and intensity imbalance effects in nonplanar phase-shifting photomasks, offer a leg-up in analyzing coronagraph masks. However, the accuracy in magnitude and phase required for modeling a chronograph system is extremely demanding and previously inconsequential errors may be of the same order of magnitude as the physical phenomena under study. In this paper, effects of thick masks, finite conductivity metals, and various cross-section geometries on the transmission of pupil-plane masks are illustrated. Undercutting the edge shape of Cr masks improves the effective opening width to within λ/5 of the actual opening but TE and TM polarizations require opposite compensations. The deviation from ideal is examined at the reference plane of the mask opening. Numerical errors in TEMPEST, such as numerical dispersion, perfectly matched layer reflections, and source haze are also discussed along with techniques for mitigating their impacts.

  12. [Impacts of different methods in laryngeal mask airway positioning on the airway management of elderly patients with general anesthesia].

    PubMed

    Yan, F; Li, J; Wang, H J; Yang, X; Yang, J B; Tu, X J

    2018-05-15

    Objective: By observing the clinical effect of ultrasound, fiberoptic bronchoscopy and traditional standard in positioning the general anesthesia of laryngeal mask ventilation in elderly patients, the superiority of laryngeal mask positioning with visualization technique of ultrasound and fiberoptic bronchoscope on airway management in elderly patients with general anesthesia was analyzed. Methods: One hundred and twenty cases of elderly patients with general anesthesia of laryngeal mask ventilation from the People's Hospital of Yuyao city from October 2016 to October 2017 were selected and randomly divided into 3 groups( n =40)according to American Society of Anesthesiologists (ASA) grading criteria Ⅰ-Ⅲ. Group A: traditional standard positioning laryngeal mask group. Group B: fiberoptic bronchoscope positioning laryngeal mask group. Group C: ultrasound positioning laryngeal mask group. The general information of sex ratio of male and female, mass, and height, and operation type, operation duration, anaesthesia duration, and modified Mallampati grade were observed and compared among the three groups. The number of successful laryngeal mask ventilation after laryngeal mask placement in 3 groups was observed, the laryngeal mask placement time (T(0)) and the normal ventilation time after adjustment (T(1)) in each group were recorded, and the first success rate of laryngeal mask placement, the success rate after adjusting the positioning, and the success rate of re-placement were calculated. Moreover, the mean peak airway pressure at 5 min after operation, the minimum intrathecal injection gas for minimum ventilation (V(min)), the minimum laryngeal mask intravesical pressure (ICP(min)), and the lowest air pressure for oral and pharyngeal leakage (OLP(min)) were recorded. The airway seal pressure (OLP(60)) and the volume of gas injection (V(60)) when the intravesical pressure was 60 cmH(2)O (1 cmH(2)O=0.098 kPa) were used to record the incidence of postoperative laryngeal mask bleeding, cough, nausea and vomiting, and the incidence of pharyngalgia, odynophagia, hoarseness and other related complications after 24 hours of the operation. Results: There was no significant difference in general information, airway evaluation and anesthesia operation among the three groups (all P >0.05). The incidence of intraoperative laryngeal mask bleeding in group B and C was 7.9% and 2.6% respectively, the incidence of odynophagia at 24 hours after operation was 5.3% and 0 respectively, and the incidence of pharyngalgia and hoarseness was 18.4% and 7.9% respectively, less than that in group A (24.2%, 12.1% and 36.3%). The difference was statistically significant (χ(2)=8.900, 6.880, 9.000, P <0.05). The success rate of adjustment and positioning after the placement of laryngeal mask was 84.2% and 94.7% respectively in group B and C, higher than that in group A of 72.7%, and the difference was statistically significant (χ(2)=6.500, P <0.05). The lowest laryngeal mask intralaryngeal pressure for ventilation in group B and C was (35.39±4.67) cmH(2)O and (32.61±3.22) cmH(2)O, lower than that in group A of (39.30 ± 5.93) cmH(2)O, the intralaryngeal pressure was 60 cmH(2)O, and the airway seal pressure was (25.82±4.48) cmH(2)O and (28.34±6.99) cmH(2)O, higher than that in group A of (22.45±4.98) cmH(2)O, which was significantly different ( F =18.200, 9.720, P <0.05). Conclusions: In elderly patients with general anesthesia, it is feasible to manage the airway by ultrasound or fiberoptic bronchoscopy with laryngeal mask. Ultrasound positioning laryngeal mask improves the accuracy of the intraoperative ventilation, and reduces the incidence of postoperative airway related complications.

  13. High Contrast Internal and External Coronagraph Masks Produced by Various Techniques

    NASA Technical Reports Server (NTRS)

    Balasubramanian, Kunjithapatha; Wilson, Daniel; White, Victor; Muller, Richard; Dickie, Matthew; Yee, Karl; Ruiz, Ronald; Shaklan, Stuart; Cady, Eric; Kern, Brian; hide

    2013-01-01

    Masks for high contrast internal and external coronagraphic imaging require a variety of masks depending on different architectures to suppress star light. Various fabrication technologies are required to address a wide range of needs including gradient amplitude transmission, tunable phase profiles, ultra-low reflectivity, precise small scale features, and low-chromaticity. We present the approaches employed at JPL to produce pupil plane and image plane coronagraph masks, and lab-scale external occulter type masks by various techniques including electron beam, ion beam, deep reactive ion etching, and black silicon technologies with illustrative examples of each. Further development is in progress to produce circular masks of various kinds for obscured aperture telescopes.

  14. Fast synthesis of topographic mask effects based on rigorous solutions

    NASA Astrophysics Data System (ADS)

    Yan, Qiliang; Deng, Zhijie; Shiely, James

    2007-10-01

    Topographic mask effects can no longer be ignored at technology nodes of 45 nm, 32 nm and beyond. As feature sizes become comparable to the mask topographic dimensions and the exposure wavelength, the popular thin mask model breaks down, because the mask transmission no longer follows the layout. A reliable mask transmission function has to be derived from Maxwell equations. Unfortunately, rigorous solutions of Maxwell equations are only manageable for limited field sizes, but impractical for full-chip optical proximity corrections (OPC) due to the prohibitive runtime. Approximation algorithms are in demand to achieve a balance between acceptable computation time and tolerable errors. In this paper, a fast algorithm is proposed and demonstrated to model topographic mask effects for OPC applications. The ProGen Topographic Mask (POTOMAC) model synthesizes the mask transmission functions out of small-sized Maxwell solutions from a finite-difference-in-time-domain (FDTD) engine, an industry leading rigorous simulator of topographic mask effect from SOLID-E. The integral framework presents a seamless solution to the end user. Preliminary results indicate the overhead introduced by POTOMAC is contained within the same order of magnitude in comparison to the thin mask approach.

  15. Uniformity Masks Design Method Based on the Shadow Matrix for Coating Materials with Different Condensation Characteristics

    PubMed Central

    2013-01-01

    An intuitionistic method is proposed to design shadow masks to achieve thickness profile control for evaporation coating processes. The proposed method is based on the concept of the shadow matrix, which is a matrix that contains coefficients that build quantitive relations between shape parameters of masks and shadow quantities of substrate directly. By using the shadow matrix, shape parameters of shadow masks could be derived simply by solving a matrix equation. Verification experiments were performed on a special case where coating materials have different condensation characteristics. By using the designed mask pair with complementary shapes, thickness uniformities of better than 98% are demonstrated for MgF2 (m = 1) and LaF3 (m = 0.5) simultaneously on a 280 mm diameter spherical substrate with the radius curvature of 200 mm. PMID:24227996

  16. OPC care-area feedforwarding to MPC

    NASA Astrophysics Data System (ADS)

    Dillon, Brian; Peng, Yi-Hsing; Hamaji, Masakazu; Tsunoda, Dai; Muramatsu, Tomoyuki; Ohara, Shuichiro; Zou, Yi; Arnoux, Vincent; Baron, Stanislas; Zhang, Xiaolong

    2016-10-01

    Demand for mask process correction (MPC) is growing for leading-edge process nodes. MPC was originally intended to correct CD linearity for narrow assist features difficult to resolve on a photomask without any correction, but it has been extended to main features as process nodes have been shrinking. As past papers have observed, MPC shows improvements in photomask fidelity. Using advanced shape and dose corrections could give more improvements, especially at line-ends and corners. However, there is a dilemma on using such advanced corrections on full mask level because it increases data volume and run time. In addition, write time on variable shaped beam (VSB) writers also increases as the number of shots increases. Optical proximity correction (OPC) care-area defines circuit design locations that require high mask fidelity under mask writing process variations such as energy fluctuation. It is useful for MPC to switch its correction strategy and permit the use of advanced mask correction techniques in those local care-areas where they provide maximum wafer benefits. The use of mask correction techniques tailored to localized post-OPC design can result in similar desired level of data volume, run time, and write time. ASML Brion and NCS have jointly developed a method to feedforward the care-area information from Tachyon LMC to NDE-MPC to provide real benefit for improving both mask writing and wafer printing quality. This paper explains the detail of OPC care-area feedforwarding to MPC between ASML Brion and NCS, and shows the results. In addition, improvements on mask and wafer simulations are also shown. The results indicate that the worst process variation (PV) bands are reduced up to 37% for a 10nm tech node metal case.

  17. Redesign of an Open-System Oxygen Face Mask With Mainstream Capnometer for Children.

    PubMed

    Napolitano, Natalie; Nishisaki, Akira; Buffman, Hayley S; Leffelman, Jessica; Maltese, Matthew R; Nadkarni, Vinay M

    2017-01-01

    Partial pressure of end-tidal carbon dioxide (P ETCO 2 ) monitoring in children is important to detect apnea or hypopnea early to intervene before hypoxemia develops. Monitoring P ETCO 2 in children without a tracheal tube is challenging. To improve P ETCO 2 measurement accuracy in a commercially available mask with a mainstream CO 2 detector, we implemented design changes with deform-and-hold shaping technology and anterior-posterior adjustment of the expiratory gas flow cup. Two sizes of redesigned face masks (small for 7-20 kg, medium for 10-40 kg) were evaluated. Initial bench testing used a simulator modeling a spontaneously breathing infant and child with a natural airway. An infant/child manikin head was connected to the breathing lung simulator. A mass flow controller provided expiratory CO 2 . Mask fit was then evaluated on healthy human subjects to identify anatomical features associated with good fit, defined as square shape capnography waveform during expiration. A 3-dimensional digital scan was used to quantify anatomical features. The gaps between face mask rims and facial surface were manually measured. Bench testing revealed a P ETCO 2 difference of 3.4 ± 1.5 mm Hg between a measured P ETCO 2 by the redesigned mask and CO 2 concentration at trachea, as compared with 6.7 ± 6.2 mm Hg between P ETCO 2 measured by nasal cannula and trachea (P < .001). In the human mask fit study, 35 children (13 ± 4 kg) with the small mask and 38 (24 ± 8 kg) with the medium mask were evaluated. Capnography tracing was successfully obtained in 86% of the small and 100% of the medium masks. In children with small-size masks, the gap between the face mask rim and the child's face was not statistically different among those with good mask fit and without (1.0 ± 1.5 mm vs 1.4 ± 1.9 mm, P = .73). P ETCO 2 measurement by a redesigned open-system face mask with a mainstream CO 2 detector was accurate in the bench setting. The redesigned face mask can attain good mask fit and accurate capnography tracings in the majority of infants and children. Copyright © 2017 by Daedalus Enterprises.

  18. [Thermoplastic mask in radiotherapy: a source of anxiety for the patient?].

    PubMed

    Arino, C; Stadelmaier, N; Dupin, C; Kantor, G; Henriques de Figueiredo, B

    2014-12-01

    The thermoplastic mask often used to immobilize patients in radiotherapy can cause varying levels of stress and anxiety. This study aimed at evaluating the anxiety related to the use of radiotherapy masks and the coping strategies adopted by patients. Nineteen patients treated with radiotherapy mask for head and neck cancer, a brain tumour or a lymphoma, were met twice by a psychologist, either after the making of the mask and the first course of radiotherapy, or in the middle and at the end of treatment. Thirty-four semi-structured interviews were treated using a thematic content analysis and 13 patients answered to anxiety (STAI-YB) and coping (WCC) scales. The STAI-YB anxiety scores related to wearing the masks were low during the radiotherapy treatment period, and were confirmed by the remarks of patients recorded during the semi-structured interviews. Most patients had a positive perception of the mask, and considered it as a friend or protection. Twelve out of the 13 patients admitting to anxiety benefited from problem focused coping strategies. Thermoplastic mask-related anxiety is low and possibly lies in the positive representation patients have about the mask. The explanations provided by health professionals on the radiotherapy mask possibly have a very positive effect on this perception. Copyright © 2014 Société française de radiothérapie oncologique (SFRO). Published by Elsevier SAS. All rights reserved.

  19. SEMATECH produces defect-free EUV mask blanks: defect yield and immediate challenges

    NASA Astrophysics Data System (ADS)

    Antohe, Alin O.; Balachandran, Dave; He, Long; Kearney, Patrick; Karumuri, Anil; Goodwin, Frank; Cummings, Kevin

    2015-03-01

    Availability of defect-free reflective mask has been one of the most critical challenges to extreme ultraviolet lithography (EUVL). To mitigate the risk, significant progress has been made on defect detection, pattern shifting, and defect repair. Clearly such mitigation strategies are based on the assumption that defect counts and sizes from incoming mask blanks must be below practical levels depending on mask specifics. The leading industry consensus for early mask product development is that there should be no defects greater than 80 nm in the quality area, 132 mm x 132 mm. In addition less than 10 defects smaller than 80 nm may be mitigable. SEMATECH has been focused on EUV mask blank defect reduction using Veeco Nexus TM IBD platform, the industry standard for mask blank production, and assessing if IBD technology can be evolved to a manufacturing solution. SEMATECH has recently announced a breakthrough reduction of defects in the mask blank deposition process resulting in the production of two defect-free EUV mask blanks at 54 nm inspection sensitivity (SiO2 equivalent). This paper will discuss the dramatic reduction of baseline EUV mask blank defects, review the current deposition process run and compare results with previous process runs. Likely causes of remaining defects will be discussed based on analyses as characterized by their compositions and whether defects are embedded in the multilayer stack or non-embedded.

  20. A new suction mask to reduce leak during neonatal resuscitation: a manikin study.

    PubMed

    Lorenz, Laila; Maxfield, Dominic A; Dawson, Jennifer A; Kamlin, C Omar F; McGrory, Lorraine; Thio, Marta; Donath, Susan M; Davis, Peter G

    2016-09-01

    Leak around the face mask is a common problem during neonatal resuscitation. A newly designed face mask using a suction system to enhance contact between the mask and the infant's face might reduce leak and improve neonatal resuscitation. The aim of the study is to determine whether leak is reduced using the suction mask (Resusi-sure mask) compared with a conventional mask (Laerdal Silicone mask) in a manikin model. Sixty participants from different professional categories (neonatal consultants, fellows, registrars, nurses, midwives and students) used each face mask in a random order to deliver 2 min of positive pressure ventilation to a manikin. Delivered airway pressures were measured using a pressure line. Inspiratory and expiratory flows were measured using a flow sensor, and expiratory tidal volumes and mask leaks were derived from these values. A median (IQR) leak of 12.1 (0.6-39.0)% was found with the conventional mask compared with 0.7 (0.2-4.6)% using the suction mask (p=0.002). 50% of the participants preferred to use the suction mask and 38% preferred to use the conventional mask. There was no correlation between leak and operator experience. A new neonatal face mask based on the suction system reduced leak in a manikin model. Clinical studies to test the safety and effectiveness of this mask are needed. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://www.bmj.com/company/products-services/rights-and-licensing/

  1. Manufacturability study of masks created by inverse lithography technology (ILT)

    NASA Astrophysics Data System (ADS)

    Martin, Patrick M.; Progler, C. J.; Xiao, G.; Gray, R.; Pang, L.; Liu, Y.

    2005-11-01

    As photolithography is pushed to fabricate deep-sub wavelength devices for 90nm, 65nm and smaller technology nodes using available exposure tools (i.e., 248nm, 193nm steppers), photomask capability is becoming extremely critical. For example, PSM masks require more complicated processing; aggressive OPC makes the writing time longer and sometimes unpredictable; and, high MEEF imposes much more stringent demands on mask quality. Therefore, in order for any new lithography technology to be adopted into production, mask manufacturability must be studied thoroughly and carefully. In this paper we will present the mask manufacturability study on mask patterns created using Inverse Lithography Technology (ILT). Unlike conventional OPC methodologies, ILT uses a unique outcome-based technology to mathematically determine the mask features that produce the desired on-wafer results. ILT solves the most critical litho challenges of the deep sub-wavelength era. Potential benefits include: higher yield; expanded litho process windows; superb pattern fidelity at 90, 65 & 45-nm nodes; and reduced time-to-silicon - all without changing the existing lithography infrastructure and design-to-silicon flow. In this study a number of cell structures were selected and used as test patterns. "Luminized patterns" were generated for binary mask and attenuated phase-shift mask. Both conventional OPC patterns and "luminized patterns" were put on a test reticle side by side, and they all have a number of variations in term of correction aggressivity level and mask complexity. Mask manufacturability, including data fracturing, writing time, mask inspection, and metrology were studied. The results demonstrate that, by optimizing the inspection recipe, masks created using ILT technology can be made and qualified using current processes with a reasonable turn-around time.

  2. Bitterness prediction of H1-antihistamines and prediction of masking effects of artificial sweeteners using an electronic tongue.

    PubMed

    Ito, Masanori; Ikehama, Kiyoharu; Yoshida, Koichi; Haraguchi, Tamami; Yoshida, Miyako; Wada, Koichi; Uchida, Takahiro

    2013-01-30

    The study objective was to quantitatively predict a drug's bitterness and estimate bitterness masking efficiency using an electronic tongue (e-Tongue). To verify the predicted bitterness by e-Tongue, actual bitterness scores were determined by human sensory testing. In the first study, bitterness intensities of eight H(1)-antihistamines were assessed by comparing the Euclidean distances between the drug and water. The distances seemed not to represent the drug's bitterness, but to be greatly affected by acidic taste. Two sensors were ultimately selected as best suited to bitterness evaluation, and the data obtained from the two sensors depicted the actual taste map of the eight drugs. A bitterness prediction model was established with actual bitterness scores from human sensory testing. Concerning basic bitter substances, such as H(1)-antihistamines, the predictability of bitterness intensity using e-Tongue was considered to be sufficiently promising. In another study, the bitterness masking efficiency when adding an artificial sweetener was estimated using e-Tongue. Epinastine hydrochloride aqueous solutions containing different levels of acesulfame potassium and aspartame were well discriminated by e-Tongue. The bitterness masking efficiency of epinastine hydrochloride with acesulfame potassium was successfully predicted using e-Tongue by several prediction models employed in the study. Copyright © 2012 Elsevier B.V. All rights reserved.

  3. Not Everybody Sees the Ness in the Darkness: Individual Differences in Masked Suffix Priming

    PubMed Central

    Medeiros, Joyse; Duñabeitia, Jon Andoni

    2016-01-01

    The present study explores the role of individual differences in polymorphemic word recognition. Participants completed a masked priming lexical decision experiment on suffixed words in which targets could be preceded by suffix-related words (words sharing the same suffix) or by affixed primes with a different suffix. Participants also completed a monomorphemic word lexical decision and were divided in two groups (fast and slow readers) according to their performance in this task. When the suffix priming data were analyzed taking into consideration participants' reading speed as a proxy for their greater reliance on orthography or on semantics, a significant interaction between reading speed and the magnitude of the masked suffix priming effects emerged. Only slow participants showed significant priming effects, whereas faster participants showed negligible masked suffix priming effects. These results demonstrate that different reading profiles modulate the access to morphological information in a qualitatively different manner and that individual differences in reading determine the manner in which polymorphemic words are processed. PMID:27790180

  4. Dynamics of normalization underlying masking in human visual cortex.

    PubMed

    Tsai, Jeffrey J; Wade, Alex R; Norcia, Anthony M

    2012-02-22

    Stimulus visibility can be reduced by other stimuli that overlap the same region of visual space, a process known as masking. Here we studied the neural mechanisms of masking in humans using source-imaged steady state visual evoked potentials and frequency-domain analysis over a wide range of relative stimulus strengths of test and mask stimuli. Test and mask stimuli were tagged with distinct temporal frequencies and we quantified spectral response components associated with the individual stimuli (self terms) and responses due to interaction between stimuli (intermodulation terms). In early visual cortex, masking alters the self terms in a manner consistent with a reduction of input contrast. We also identify a novel signature of masking: a robust intermodulation term that peaks when the test and mask stimuli have equal contrast and disappears when they are widely different. We fit all of our data simultaneously with family of a divisive gain control models that differed only in their dynamics. Models with either very short or very long temporal integration constants for the gain pool performed worse than a model with an integration time of ∼30 ms. Finally, the absolute magnitudes of the response were controlled by the ratio of the stimulus contrasts, not their absolute values. This contrast-contrast invariance suggests that many neurons in early visual cortex code relative rather than absolute contrast. Together, these results provide a more complete description of masking within the normalization framework of contrast gain control and suggest that contrast normalization accomplishes multiple functional goals.

  5. LC and LD50 values of Bacillus thuringiensis Serovar japonensis strain buibui toxin to Oriental beetle and northern masked chafer larvae (Coleoptera: Scarabaeidae).

    PubMed

    Mashtoly, Tamer A; El-Zemaity, Mohamed El-Said; Hussien, Mohamed I; Alm, Steven R

    2009-10-01

    Bacillus thuringiensis serovar japonensis strain Buibui has the potential to be an important control agent for pest scarabs. Bioassays were designed to test B. t. japonensis against two of the major turf and ornamental scarab pests infesting turfgrasses and ornamentals and to serve as a basis for further tests against other scarab pests. LC and LD50 values of B. t. serovarjaponensis strain Buibui toxin and spores were determined by four different bioassays for the oriental beetle, Anomala orientalis (Waterhouse), and northern masked chafer, Cyclocephala borealis Arrow. Oriental beetle larvae were bioassayed in autoclaved and nonautoclaved soil from where they were collected (Kingston, RI [native]), in nonautoclaved soil from where the northern masked chafer larvae were collected (Groton, CT [foreign]), and per os. Northern masked chafer larvae were bioassayed in autoclaved and nonautoclaved soil from where they were collected (Groton, CT [native]), in nonautoclaved soil from where the oriental beetle larvae were collected (Kingston, RI [foreign]) and per os. LC50 values of 3.93 microg toxin/g autoclaved native soil, 1.80 microg toxin/g nonautoclaved native soil, and 0.42 microg toxin/g nonautoclaved foreign soil and an LD50 value of 0.41 microg per os were determined at 14 d forA. orientalis. LC50 values of 588.28 microg toxin/g autoclaved native soil, 155.10 microg toxin/g nonautoclaved native soil, 265.32 microg toxin/g nonautoclaved foreign soil, and LD50 of 5.21 microg per os were determined at 14 d (soils) and 10 d (per os) for C. borealis. There were significant differences in LC50 values for oriental beetles in autoclaved, nonautoclaved native soil and nonautoclaved foreign soil. There were significant differences in LCo values for northern masked chafers in autoclaved and nonautoclaved native soil. B. t. japonensis can be applied now for control of oriental beetles at rates that are economically competitive with synthetic chemicals. If we can determine the component of nonautoclaved soil that enhances the activity of toxin, it may be possible to lower the rates of toxin needed for control to more economical levels for more difficult to control species such as the northern masked chafer.

  6. Nasal versus face mask for multiple-breath washout technique in preterm infants.

    PubMed

    Schulzke, S M; Deeptha, K; Sinhal, S; Baldwin, D N; Pillow, J J

    2008-09-01

    The large dead space associated with face masks might impede the accuracy and feasibility of multiple-breath washout (MBW) measurements in small infants. We asked if a low dead space nasal mask would provide measurements of resting lung volume and ventilation inhomogeneity comparable to those obtained with a face mask, when using the MBW technique. Unsedated preterm infants breathing without mechanical assistance and weighing between 1.50 and 2.49 kg were studied. Paired MBW tests with nasal and face masks were obtained using sulphur hexafluoride (SF(6)) as the tracer gas. The order of mask application was quasi-randomized. Bland-Altman method and intraclass correlation coefficient were used to analyze outcomes. Measurements were obtained in 20 infants with a mean (SD) postmenstrual age of 36 (1.4) w and a test weight of 2.0 (0.3) kg. The mean difference (95% CI) for nasal vs. face mask was -3.2 breaths/min (-6.2, -0.1 breaths/min) for respiratory rate, -1.0 ml/kg (-2.3, 0.3 ml/kg) for lung volume, 0.6 (0.1, 1.1) for lung clearance index, 0.2 (0.1, 0.3) for first to zeroeth moment ratio and 1.33 (0.6, 2.4) for second to zeroeth moment ratio. Paired measurements of lung volume showed acceptable agreement and good correlation, but there was poor agreement and poor correlation between indices of ventilation inhomogeneity obtained with the two masks. Functional dead space of the nasal mask was similar to that of the face mask despite its smaller water displacement volume. During MBW in infants below 2.5 kg body weight, a nasal mask results in comparable lung volume measurements. Indices of ventilation inhomogeneity may not be directly comparable using masks with different dead space. (c) 2008 Wiley-Liss, Inc.

  7. Method and apparatus for inspecting an EUV mask blank

    DOEpatents

    Goldberg, Kenneth A.

    2005-11-08

    An apparatus and method for at-wavelength EUV mask-blank characterization for inspection of moderate and low spatial frequency coating uniformity using a synchrotron or other source of EUV light. The apparatus provides for rapid, non-destruction, non-contact, at-wavelength qualification of large mask areas, and can be self-calibrating or be calibrated to well-characterized reference samples. It can further check for spatial variation of mask reflectivity or for global differences among masks. The apparatus and method is particularly suited for inspection of coating uniformity and quality and can detect defects in the order of 50 .mu.m and above.

  8. Marquardt's Phi mask: pitfalls of relying on fashion models and the golden ratio to describe a beautiful face.

    PubMed

    Holland, E

    2008-03-01

    Stephen Marquardt has derived a mask from the golden ratio that he claims represents the "ideal" facial archetype. Many have found his mask convincing, including cosmetic surgeons. However, Marquardt's mask is associated with numerous problems. The method used to examine goodness of fit with the proportions in the mask is faulty. The mask is ill-suited for non-European populations, especially sub-Saharan Africans and East Asians. The mask also appears to approximate the face shape of masculinized European women. Given that the general public strongly and overwhelmingly prefers above average facial femininity in women, white women seeking aesthetic facial surgery would be ill-advised to aim toward a better fit with Marquardt's mask. This article aims to show the proper way of assessing goodness of fit with Marquardt's mask, to address the shape of the mask as it pertains to masculinity-femininity, and to discuss the broader issue of an objective assessment of facial attractiveness. Generalized Procrustes analysis is used to show how goodness of fit with Marquardt's mask can be assessed. Thin-plate spline analysis is used to illustrate visually how sample faces, including northwestern European averages, differ from Marquardt's mask. Marquardt's mask best describes the facial proportions of masculinized white women as seen in fashion models. Marquardt's mask does not appear to describe "ideal" face shape even for white women because its proportions are inconsistent with the optimal preferences of most people, especially with regard to femininity.

  9. Speech segregation based-on binaural cue: interaural time difference (itd) and interaural level difference (ild)

    NASA Astrophysics Data System (ADS)

    Nur Farid, Mifta; Arifianto, Dhany

    2016-11-01

    A person who is suffering from hearing loss can be helped by using hearing aids and the most optimal performance of hearing aids are binaural hearing aids because it has similarities to human auditory system. In a conversation at a cocktail party, a person can focus on a single conversation even though the background sound and other people conversation is quite loud. This phenomenon is known as the cocktail party effect. In an early study, has been explained that binaural hearing have an important contribution to the cocktail party effect. So in this study, will be performed separation on the input binaural sound with 2 microphone sensors of two sound sources based on both the binaural cue, interaural time difference (ITD) and interaural level difference (ILD) using binary mask. To estimate value of ITD, is used cross-correlation method which the value of ITD represented as time delay of peak shifting at time-frequency unit. Binary mask is estimated based on pattern of ITD and ILD to relative strength of target that computed statistically using probability density estimation. Results of sound source separation performing well with the value of speech intelligibility using the percent correct word by 86% and 3 dB by SNR.

  10. Phonological and Orthographic Overlap Effects in Fast and Masked Priming

    PubMed Central

    Frisson, Steven; Bélanger, Nathalie N.; Rayner, Keith

    2014-01-01

    We investigated how orthographic and phonological information is activated during reading, using a fast priming task, and during single word recognition, using masked priming. Specifically, different types of overlap between prime and target were contrasted: high orthographic and high phonological overlap (track-crack), high orthographic and low phonological overlap (bear-gear), or low orthographic and high phonological overlap (fruit-chute). In addition, we examined whether (orthographic) beginning overlap (swoop-swoon) yielded the same priming pattern as end (rhyme) overlap (track-crack). Prime durations were 32 and 50ms in the fast priming version, and 50ms in the masked priming version, and mode of presentation (prime and target in lower case) was identical. The fast priming experiment showed facilitatory priming effects when both orthography and phonology overlapped, with no apparent differences between beginning and end overlap pairs. Facilitation was also found when prime and target only overlapped orthographically. In contrast, the masked priming experiment showed inhibition for both types of end overlap pairs (with and without phonological overlap), and no difference for begin overlap items. When prime and target only shared principally phonological information, facilitation was only found with a long prime duration in the fast priming experiment, while no differences were found in the masked priming version. These contrasting results suggest that fast priming and masked priming do not necessarily tap into the same type of processing. PMID:24365065

  11. Color image encryption based on gyrator transform and Arnold transform

    NASA Astrophysics Data System (ADS)

    Sui, Liansheng; Gao, Bo

    2013-06-01

    A color image encryption scheme using gyrator transform and Arnold transform is proposed, which has two security levels. In the first level, the color image is separated into three components: red, green and blue, which are normalized and scrambled using the Arnold transform. The green component is combined with the first random phase mask and transformed to an interim using the gyrator transform. The first random phase mask is generated with the sum of the blue component and a logistic map. Similarly, the red component is combined with the second random phase mask and transformed to three-channel-related data. The second random phase mask is generated with the sum of the phase of the interim and an asymmetrical tent map. In the second level, the three-channel-related data are scrambled again and combined with the third random phase mask generated with the sum of the previous chaotic maps, and then encrypted into a gray scale ciphertext. The encryption result has stationary white noise distribution and camouflage property to some extent. In the process of encryption and decryption, the rotation angle of gyrator transform, the iterative numbers of Arnold transform, the parameters of the chaotic map and generated accompanied phase function serve as encryption keys, and hence enhance the security of the system. Simulation results and security analysis are presented to confirm the security, validity and feasibility of the proposed scheme.

  12. Masked Chimeric Antigen Receptor for Tumor-Specific Activation.

    PubMed

    Han, Xiaolu; Bryson, Paul D; Zhao, Yifan; Cinay, Gunce E; Li, Si; Guo, Yunfei; Siriwon, Natnaree; Wang, Pin

    2017-01-04

    Adoptive cellular therapy based on chimeric antigen receptor (CAR)-engineered T (CAR-T) cells is a powerful form of cancer immunotherapy. CAR-T cells can be redirected to specifically recognize tumor-associated antigens (TAAs) and induce high levels of antitumor activity. However, they may also display "on-target off-tumor" toxicities, resulting from low-level expression of TAAs in healthy tissues. These adverse effects have raised considerable safety concerns and limited the clinical application of this otherwise promising therapeutic modality. To minimize such side effects, we have designed an epidermal growth factor receptor (EGFR)-specific masked CAR (mCAR), which consists of a masking peptide that blocks the antigen-binding site and a protease-sensitive linker. Proteases commonly active in the tumor microenvironment can cleave the linker and disengage the masking peptide, thereby enabling CAR-T cells to recognize target antigens only at the tumor site. In vitro mCAR showed dramatically reduced antigen binding and antigen-specific activation in the absence of proteases, but normal levels of binding and activity upon treatment with certain proteases. Masked CAR-T cells also showed antitumor efficacy in vivo comparable to that of unmasked CAR. Our study demonstrates the feasibility of improving the safety profile of conventional CARs and may also inspire future design of CAR molecules targeting broadly expressed TAAs. Copyright © 2017 The American Society of Gene and Cell Therapy. Published by Elsevier Inc. All rights reserved.

  13. Software-based data path for raster-scanned multi-beam mask lithography

    NASA Astrophysics Data System (ADS)

    Rajagopalan, Archana; Agarwal, Ankita; Buck, Peter; Geller, Paul; Hamaker, H. Christopher; Rao, Nagswara

    2016-10-01

    According to the 2013 SEMATECH Mask Industry Survey,i roughly half of all photomasks are produced using laser mask pattern generator ("LMPG") lithography. LMPG lithography can be used for all layers at mature technology nodes, and for many non-critical and semi-critical masks at advanced nodes. The extensive use of multi-patterning at the 14-nm node significantly increases the number of critical mask layers, and the transition in wafer lithography from positive tone resist to negative tone resist at the 14-nm design node enables the switch from advanced binary masks back to attenuated phase shifting masks that require second level writes to remove unwanted chrome. LMPG lithography is typically used for second level writes due to its high productivity, absence of charging effects, and versatile non-actinic alignment capability. As multi-patterning use expands from double to triple patterning and beyond, the number of LMPG second level writes increases correspondingly. The desire to reserve the limited capacity of advanced electron beam writers for use when essential is another factor driving the demand for LMPG capacity. The increasing demand for cost-effective productivity has kept most of the laser mask writers ever manufactured running in production, sometimes long past their projected lifespan, and new writers continue to be built based on hardware developed some years ago.ii The data path is a case in point. While state-ofthe- art when first introduced, hardware-based data path systems are difficult to modify or add new features to meet the changing requirements of the market. As data volumes increase, design styles change, and new uses are found for laser writers, it is useful to consider a replacement for this critical subsystem. The availability of low-cost, high-performance, distributed computer systems combined with highly scalable EDA software lends itself well to creating an advanced data path system. EDA software, in routine production today, scales well to hundreds or even thousands of CPU-cores, offering the potential for virtually unlimited capacity. Features available in EDA software such as sizing, scaling, tone reversal, OPC, MPC, rasterization, and others are easily adapted to the requirements of a data path system. This paper presents the motivation, requirements, design and performance of an advanced, scalable software data path system suitable to support multi-beam laser mask lithography.

  14. Method of fabricating a 3-dimensional tool master

    DOEpatents

    Bonivert, William D.; Hachman, John T.

    2002-01-01

    The invention is a method for the fabrication of an imprint tool master. The process begins with a metallic substrate. A layer of photoresist is placed onto the metallic substrate and a image pattern mask is then aligned to the mask. The mask pattern has opaque portions that block exposure light and "open" or transparent portions which transmit exposure light. The photoresist layer is then exposed to light transmitted through the "open" portions of the first image pattern mask and the mask is then removed. A second layer of photoresist then can be placed onto the first photoresist layer and a second image pattern mask may be placed on the second layer of photoresist. The second layer of photoresist is exposed to light, as before, and the second mask removed. The photoresist layers are developed simultaneously to produce a multi-level master mandrel upon which a conductive film is formed. A tool master can now be formed onto the conductive film. An imprint tool is then produced from the tool master. In one embodiment, nickel is electroplated onto the tool master to produce a three-dimensional imprint tool.

  15. New mask technology challenges

    NASA Astrophysics Data System (ADS)

    Kimmel, Kurt R.

    2001-09-01

    Mask technology development has accelerated dramatically in recent years from the glacial pace of the last three decades to the rapid and sometimes simultaneous introductions of new wavelengths and mask-based resolution enhancement techniques. The nature of the semiconductor business has also become one driven by time-to-market as an overwhelming factor in capturing market share and profit. These are among the factors that have created enormous stress on the mask industry to produce masks with enhanced capabilities, such as phase-shifting attenuators, sub-resolution assist bars, and optical proximity correction (OPC) features, while maintaining or reducing cost and cycle time. The mask can no longer be considered a commodity item that is purchased form the lowest-cost supplier. Instead, it must now be promoted as an integral part of the technical and business case for a total lithographic solution. Improving partnership between designer, mask-maker, and wafer lithographer will be the harbinger of success in finding a profitable balance of capability, cost, and cycle time. Likewise for equipment infrastructure development, stronger partnership on the international level is necessary to control development cost and mitigate schedule and technical risks.

  16. Non-invasive primate head restraint using thermoplastic masks.

    PubMed

    Drucker, Caroline B; Carlson, Monica L; Toda, Koji; DeWind, Nicholas K; Platt, Michael L

    2015-09-30

    The success of many neuroscientific studies depends upon adequate head fixation of awake, behaving animals. Typically, this is achieved by surgically affixing a head-restraint prosthesis to the skull. Here we report the use of thermoplastic masks to non-invasively restrain monkeys' heads. Mesh thermoplastic sheets become pliable when heated and can then be molded to an individual monkey's head. After cooling, the custom mask retains this shape indefinitely for day-to-day use. We successfully trained rhesus macaques (Macaca mulatta) to perform cognitive tasks while wearing thermoplastic masks. Using these masks, we achieved a level of head stability sufficient for high-resolution eye-tracking and intracranial electrophysiology. Compared with traditional head-posts, we find that thermoplastic masks perform at least as well during infrared eye-tracking and single-neuron recordings, allow for clearer magnetic resonance image acquisition, enable freer placement of a transcranial magnetic stimulation coil, and impose lower financial and time costs on the lab. We conclude that thermoplastic masks are a viable non-invasive form of primate head restraint that enable a wide range of neuroscientific experiments. Copyright © 2015 Elsevier B.V. All rights reserved.

  17. Particulate face masks for protection against airborne pathogens - one size does not fit all: an observational study.

    PubMed

    Winter, Susan; Thomas, Jane H; Stephens, Dianne P; Davis, Joshua S

    2010-03-01

    To determine the proportion of hospital staff who pass fit tests with each of three commonly used particulate face masks, and factors influencing preference and fit test results. Observational study. 50 healthy hospital staff volunteers in an 18-bed general intensive care unit in an Australian teaching hospital. Participants were administered a questionnaire about mask use and their preferred mask and underwent qualitative fit-testing with each of three different particulate masks: Kimberly-Clark Tecnol FluidShield N95 particulate filter respirator (KC), 3M Flat Fold 9320 particulate respirator and 3M 8822 particulate respirator with exhalation valve. Participants who failed fittesting were trained in correct mask donning, and fittesting was repeated. Proportion of participants who passed the fit test for each mask and the effect of training. The proportion of participants who passed a fit test was low for all three masks tested (KC, 16%; flat fold, 28%; and valved, 34%). Rates improved after training: the first mask tested fitted in 18% of participants pre-training and 40% post-training (P = 0.02). None of the masks fitted for 28% of participants. There were no significant predictors of fit-test results. A large proportion of individuals failed a fit test with any given mask, and we were not able to identify any factors that predicted mask fit in individuals. Training on mask use improved the rates of adequate fit. Hospitals should carry a range of P2 masks, and should conduct systematic P2 mask training and fit-testing programs for all staff potentially exposed to airborne pathogens.

  18. The contribution of forward masking to saccadic inhibition of return.

    PubMed

    Souto, David; Born, Sabine; Kerzel, Dirk

    2018-03-08

    Inhibition of return is the name typically given to the prolonged latency of motor responses directed to a previously cued target location. There is intense debate about the origins of this effect and its function, but most take for granted (despite lack of evidence) that it depends little on forward masking. Therefore, we re-examined the role of forward masking in inhibition of return. Forward masking was indexed by slower saccadic reaction times (SRTs) when the target orientation repeated the cue orientation at the same location. We confirmed effects of orientation repetition in the absence of an attentional bias when cues were presented on both sides of fixation (bilateral presentation). The effect of orientation repetition was reduced with high target contrast, consistent with a low-level origin such as contrast gain control in early visual areas. When presenting cues on only one side of fixation (unilateral presentation), we obtained inhibition of return with longer cue-target intervals and facilitation with targets presented shortly after the cue. The effect of orientation repetition was reduced when facilitation was observed, but was as strong as with bilateral cues when inhibition of return was observed. Therefore, forward masking may contribute to the inhibition of return effect by delaying reaction times to repeated features at the same location, but is not a principal cause of inhibition of return; in agreement with previous views. The saccadic inhibition of return effect is a reaction-time cost when responding to a pre-cued location. Additional object updating costs are typically invoked to explain reaction-time costs observed when cue and target have the same shape. Yet, lower-level, forward masking of the target by the cue can not be ruled out. Importantly, we show an effect of orientation repetition that is consistent with low-level forward masking rather than object updating costs and that does not interact with inhibition of return.

  19. The Attentional Blink Is Not Affected by Backward Masking of T2, T2-Mask SOA, or Level of T2 Impoverishment

    ERIC Educational Resources Information Center

    Jannati, Ali; Spalek, Thomas M.; Lagroix, Hayley E. P.; Di Lollo, Vincent

    2012-01-01

    Identification of the second of two targets (T2) is impaired when presented shortly after the first (T1). This "attentional blink" (AB) is thought to arise from a delay in T2 processing during which T2 is vulnerable to masking. Conventional studies have measured T2 accuracy which is constrained by the 100% ceiling. We avoided this problem by using…

  20. Neonatal mannequin comparison of the Upright self-inflating bag and snap-fit mask versus standard resuscitators and masks: leak, applied load and tidal volumes.

    PubMed

    Rafferty, Anthony Richard; Johnson, Lucy; Davis, Peter G; Dawson, Jennifer Anne; Thio, Marta; Owen, Louise S

    2017-11-30

    Neonatal mask ventilation is a difficult skill to acquire and maintain. Mask leak is common and can lead to ineffective ventilation. The aim of this study was to determine whether newly available neonatal self-inflating bags and masks could reduce mask leak without additional load being applied to the face. Forty operators delivered 1 min episodes of mask ventilation to a mannequin using the Laerdal Upright Resuscitator, a standard Laerdal infant resuscitator (Laerdal Medical) and a T-Piece Resuscitator (Neopuff), using both the Laerdal snap-fit face mask and the standard Laerdal size 0/1 face mask (equivalent sizes). Participants were asked to use pressure sufficient to achieve 'appropriate' chest rise. Leak, applied load, airway pressure and tidal volume were measured continuously. Participants were unaware that load was being recorded. There was no difference in mask leak between resuscitation devices. Leak was significantly lower when the snap-fit mask was used with all resuscitation devices, compared with the standard mask (14% vs 37% leak, P<0.01). The snap-fit mask was preferred by 83% of participants. The device-mask combinations had no significant effect on applied load. The Laerdal Upright Resuscitator resulted in similar leak to the other resuscitation devices studied, and did not exert additional load to the face and head. The snap-fit mask significantly reduced overall leak with all resuscitation devices and was the mask preferred by participants. © Article author(s) (or their employer(s) unless otherwise stated in the text of the article) 2017. All rights reserved. No commercial use is permitted unless otherwise expressly granted.

  1. Identification of optimal mask size parameter for noise filtering in 99mTc-methylene diphosphonate bone scintigraphy images.

    PubMed

    Pandey, Anil K; Bisht, Chandan S; Sharma, Param D; ArunRaj, Sreedharan Thankarajan; Taywade, Sameer; Patel, Chetan; Bal, Chandrashekhar; Kumar, Rakesh

    2017-11-01

    Tc-methylene diphosphonate (Tc-MDP) bone scintigraphy images have limited number of counts per pixel. A noise filtering method based on local statistics of the image produces better results than a linear filter. However, the mask size has a significant effect on image quality. In this study, we have identified the optimal mask size that yields a good smooth bone scan image. Forty four bone scan images were processed using mask sizes 3, 5, 7, 9, 11, 13, and 15 pixels. The input and processed images were reviewed in two steps. In the first step, the images were inspected and the mask sizes that produced images with significant loss of clinical details in comparison with the input image were excluded. In the second step, the image quality of the 40 sets of images (each set had input image, and its corresponding three processed images with 3, 5, and 7-pixel masks) was assessed by two nuclear medicine physicians. They selected one good smooth image from each set of images. The image quality was also assessed quantitatively with a line profile. Fisher's exact test was used to find statistically significant differences in image quality processed with 5 and 7-pixel mask at a 5% cut-off. A statistically significant difference was found between the image quality processed with 5 and 7-pixel mask at P=0.00528. The identified optimal mask size to produce a good smooth image was found to be 7 pixels. The best mask size for the John-Sen Lee filter was found to be 7×7 pixels, which yielded Tc-methylene diphosphonate bone scan images with the highest acceptable smoothness.

  2. Tinnitus retraining therapy: mixing point and total masking are equally effective.

    PubMed

    Tyler, Richard S; Noble, William; Coelho, Claudia Barros; Ji, Haihong

    2012-01-01

    Habituation to tinnitus cannot occur with total masking, an argument made by proponents of "tinnitus retraining therapy." We also compared the effectiveness of retraining therapy with mixing-point masking, total masking, and with counseling alone. Forty-eight tinnitus patients were randomly assigned to one of three groups: counseling, counseling plus bilateral noise generators set to completely mask the tinnitus, or counseling plus bilateral noise generators with a focus on the mixing point (partial masking just below total masking). A picture-based counseling protocol was used to assist in providing similar counseling among all three groups. The Tinnitus Handicap Questionnaire was administered before and after about 12 months of treatment. After 12 months, in the counseling group, three of 18 patients benefited significantly, in the mixing-point group, six of 19 patients benefited, and in the total masking group, four of 11 patients benefited from the treatment. The average decrease in the questionnaire was 16.7% for the counseling group, 31.6% for the retraining group, and 36.4% for the total masking group. No significant average differences among groups were observed. One premise of retraining therapy is incorrect; a focus on mixing-point masking is not required for habituation.

  3. Metacontrast masking and attention do not interact.

    PubMed

    Agaoglu, Sevda; Breitmeyer, Bruno; Ogmen, Haluk

    2016-07-01

    Visual masking and attention have been known to control the transfer of information from sensory memory to visual short-term memory. A natural question is whether these processes operate independently or interact. Recent evidence suggests that studies that reported interactions between masking and attention suffered from ceiling and/or floor effects. The objective of the present study was to investigate whether metacontrast masking and attention interact by using an experimental design in which saturation effects are avoided. We asked observers to report the orientation of a target bar randomly selected from a display containing either two or six bars. The mask was a ring that surrounded the target bar. Attentional load was controlled by set-size and masking strength by the stimulus onset asynchrony between the target bar and the mask ring. We investigated interactions between masking and attention by analyzing two different aspects of performance: (i) the mean absolute response errors and (ii) the distribution of signed response errors. Our results show that attention affects observers' performance without interacting with masking. Statistical modeling of response errors suggests that attention and metacontrast masking exert their effects by independently modulating the probability of "guessing" behavior. Implications of our findings for models of attention are discussed.

  4. Compensation of flare-induced CD changes EUVL

    DOEpatents

    Bjorkholm, John E [Pleasanton, CA; Stearns, Daniel G [Los Altos, CA; Gullikson, Eric M [Oakland, CA; Tichenor, Daniel A [Castro Valley, CA; Hector, Scott D [Oakland, CA

    2004-11-09

    A method for compensating for flare-induced critical dimensions (CD) changes in photolithography. Changes in the flare level results in undesirable CD changes. The method when used in extreme ultraviolet (EUV) lithography essentially eliminates the unwanted CD changes. The method is based on the recognition that the intrinsic level of flare for an EUV camera (the flare level for an isolated sub-resolution opaque dot in a bright field mask) is essentially constant over the image field. The method involves calculating the flare and its variation over the area of a patterned mask that will be imaged and then using mask biasing to largely eliminate the CD variations that the flare and its variations would otherwise cause. This method would be difficult to apply to optical or DUV lithography since the intrinsic flare for those lithographies is not constant over the image field.

  5. Effects of the intensity of masking noise on ear canal recorded low-frequency cochlear microphonic waveforms in normal hearing subjects.

    PubMed

    Zhang, Ming

    2014-07-01

    Compared to auditory brainstem responses (ABRs), cochlear microphonics (CMs) may be more appropriate to serve as a supplement to the test of otoacoustic emissions (OAEs). Researchers have shown that low-frequency CMs from the apical cochlea are measurable at the tympanic membrane using high-pass masking noise. Our objective is to study the effect of such noise at different intensities on low-frequency CMs recorded at the ear canal, which is not completely known. Six components were involved in this CM measurement including an ear canal electrode (1), a relatively long and low-frequency toneburst (2), and high-pass masking noise at different intensities (3). The rest components include statistical analysis based on multiple human subjects (4), curve modeling based on amplitudes of CM waveforms (CMWs) and noise intensity (5), and a technique based on electrocochleography (ECochG or ECoG) (6). Results show that low-frequency CMWs appeared clearly. The CMW amplitude decreased with an increase in noise level. It decreased first slowly, then faster, and finally slowly again. In conclusion, when masked with high-pass noise, the low-frequency CMs are measurable at the human ear canal. Such noise reduces the low-frequency CM amplitude. The reduction is noise-intensity dependent but not completely linear. The reduction may be caused by the excited basal cochlea which the low-frequency has to travel and pass through. Although not completely clear, six mechanisms related to such reduction are discussed. Copyright © 2014 Elsevier B.V. All rights reserved.

  6. Heterogeneity and Glycan Masking of Cell Wall Microstructures in the Stems of Miscanthus x giganteus, and Its Parents M. sinensis and M. sacchariflorus

    PubMed Central

    Xue, Jie; Bosch, Maurice; Knox, J. Paul

    2013-01-01

    Plant cell walls, being repositories of fixed carbon, are important sources of biomass and renewable energy. Miscanthus species are fast growing grasses with a high biomass yield and they have been identified as potential bioenergy crops. Miscanthus x giganteus is the sterile hybrid between M. sinensis and M. sacchariflorus, with a faster and taller growth than its parents. In this study, the occurrence of cell wall polysaccharides in stems of Miscanthus species has been determined using fluorescence imaging with sets of cell wall directed monoclonal antibodies. Heteroxylan and mixed linkage-glucan (MLG) epitopes are abundant in stem cell walls of Miscanthus species, but their distributions are different in relation to the interfascicular parenchyma and these epitopes also display different developmental dynamics. Detection of pectic homogalacturonan (HG) epitopes was often restricted to intercellular spaces of parenchyma regions and, notably, the high methyl ester LM20 HG epitope was specifically abundant in the pith parenchyma cell walls of M. x giganteus. Some cell wall probes cannot access their target glycan epitopes because of masking by other polysaccharides. In the case of Miscanthus stems, masking of xyloglucan by heteroxylan and masking of pectic galactan by heteroxylan and MLG was detected in certain cell wall regions. Knowledge of tissue level heterogeneity of polysaccharide distributions and molecular architectures in Miscanthus cell wall structures will be important for both understanding growth mechanisms and also for the development of potential strategies for the efficient deconstruction of Miscanthus biomass. PMID:24312403

  7. Face Masks and Cough Etiquette Reduce the Cough Aerosol Concentration of Pseudomonas aeruginosa in People with Cystic Fibrosis.

    PubMed

    Wood, Michelle E; Stockwell, Rebecca E; Johnson, Graham R; Ramsay, Kay A; Sherrard, Laura J; Jabbour, Nassib; Ballard, Emma; O'Rourke, Peter; Kidd, Timothy J; Wainwright, Claire E; Knibbs, Luke D; Sly, Peter D; Morawska, Lidia; Bell, Scott C

    2018-02-01

    People with cystic fibrosis (CF) generate Pseudomonas aeruginosa in droplet nuclei during coughing. The use of surgical masks has been recommended in healthcare settings to minimize pathogen transmission between patients with CF. To determine if face masks and cough etiquette reduce viable P. aeruginosa aerosolized during coughing. Twenty-five adults with CF and chronic P. aeruginosa infection were recruited. Participants performed six talking and coughing maneuvers, with or without face masks (surgical and N95) and hand covering the mouth when coughing (cough etiquette) in an aerosol-sampling device. An Andersen Cascade Impactor was used to sample the aerosol at 2 meters from each participant. Quantitative sputum and aerosol bacterial cultures were performed, and participants rated the mask comfort levels during the cough maneuvers. During uncovered coughing (reference maneuver), 19 of 25 (76%) participants produced aerosols containing P. aeruginosa, with a positive correlation found between sputum P. aeruginosa concentration (measured as cfu/ml) and aerosol P. aeruginosa colony-forming units. There was a reduction in aerosol P. aeruginosa load during coughing with a surgical mask, coughing with an N95 mask, and cough etiquette compared with uncovered coughing (P < 0.001). A similar reduction in total colony-forming units was observed for both masks during coughing; yet, participants rated the surgical masks as more comfortable (P = 0.013). Cough etiquette provided approximately half the reduction of viable aerosols of the mask interventions during voluntary coughing. Talking was a low viable aerosol-producing activity. Face masks reduce cough-generated P. aeruginosa aerosols, with the surgical mask providing enhanced comfort. Cough etiquette was less effective at reducing viable aerosols.

  8. An interactive tool for gamut masking

    NASA Astrophysics Data System (ADS)

    Song, Ying; Lau, Cheryl; Süsstrunk, Sabine

    2014-02-01

    Artists often want to change the colors of an image to achieve a particular aesthetic goal. For example, they might limit colors to a warm or cool color scheme to create an image with a certain mood or feeling. Gamut masking is a technique that artists use to limit the set of colors they can paint with. They draw a mask over a color wheel and only use the hues within the mask. However, creating the color palette from the mask and applying the colors to the image requires skill. We propose an interactive tool for gamut masking that allows amateur artists to create an image with a desired mood or feeling. Our system extracts a 3D color gamut from the 2D user-drawn mask and maps the image to this gamut. The user can draw a different gamut mask or locally refine the image colors. Our voxel grid gamut representation allows us to represent gamuts of any shape, and our cluster-based image representation allows the user to change colors locally.

  9. Masking Release in Children and Adults with Hearing Loss When Using Amplification

    ERIC Educational Resources Information Center

    Brennan, Marc; McCreery, Ryan; Kopun, Judy; Lewis, Dawna; Alexander, Joshua; Stelmachowicz, Patricia

    2016-01-01

    Purpose: This study compared masking release for adults and children with normal hearing and hearing loss. For the participants with hearing loss, masking release using simulated hearing aid amplification with 2 different compression speeds (slow, fast) was compared. Method: Sentence recognition in unmodulated noise was compared with recognition…

  10. Mechanisms of Masked Priming: Testing the Entry Opening Model

    ERIC Educational Resources Information Center

    Wu, Hongmei

    2012-01-01

    Since it was introduced in Forster and Davis (1984), masked priming has been widely adopted in the psycholinguistic research on visual word recognition, but there has been little consensus on its actual mechanisms, i.e. how it occurs and how it should be interpreted. This dissertation addresses two different interpretations of masked priming, one…

  11. Cerebral Asymmetries in Early Orthographic and Phonological Reading Processes: Evidence from Backward Masking

    ERIC Educational Resources Information Center

    Halderman, Laura K.; Chiarello, Christine

    2005-01-01

    A lateralized backward masking paradigm was used to examine hemisphere differences in orthographic and phonological processes at an early time course of word recognition. Targets (e.g., bowl) were presented and backward masked by either pseudohomophones of the target word (orthographically and phonologically similar, e.g., BOAL), orthographically…

  12. Invariant correlation to position and rotation using a binary mask applied to binary and gray images

    NASA Astrophysics Data System (ADS)

    Álvarez-Borrego, Josué; Solorza, Selene; Bueno-Ibarra, Mario A.

    2013-05-01

    In this paper more alternative ways to generate the binary ring masks are studied and a new methodology is presented when in the analysis the image come with some distortion due to rotation. This new algorithm requires low computational cost. Signature vectors of the target so like signature vectors of the object to be recognized in the problem image are obtained using a binary ring mask constructed in accordance with the real or the imaginary part of their Fourier transform analyzing two different conditions in each one. In this manner, each image target or problem image, will have four unique binary ring masks. The four ways are analyzed and the best is chosen. In addition, due to any image with rotation include some distortion, the best transect is chosen in the Fourier plane in order to obtain the best signature through the different ways to obtain the binary mask. This methodology is applied to two cases: to identify different types of alphabetic letters in Arial font and to identify different fossil diatoms images. Considering the great similarity between diatom images the results obtained are excellent.

  13. Economics of automation for the design-to-mask interface

    NASA Astrophysics Data System (ADS)

    Erck, Wesley

    2009-04-01

    Mask order automation has increased steadily over the years through a variety of individual mask customer implementations. These have been supported by customer-specific software at the mask suppliers to support the variety of customer output formats. Some customers use the SEMI P10 1 standard, some use supplier-specific formats, and some use customer-specific formats. Some customers use little automation and depend instead on close customer-supplier relationships. Implementations are varied in quality and effectiveness. A major factor which has prolonged the adoption of more advanced and effective solutions has been a lack of understanding of the economic benefits. Some customers think standardized automation mainly benefits the mask supplier in order entry automation, but this ignores a number of other significant benefits which differ dramatically for each party in the supply chain. This paper discusses the nature of those differing advantages and presents simple models suited to four business cases: integrated device manufacturers (IDM), fabless companies, foundries and mask suppliers. Examples and estimates of the financial advantages for these business types will be shown.

  14. Serial robot for the trajectory optimization and error compensation of TMT mask exchange system

    NASA Astrophysics Data System (ADS)

    Wang, Jianping; Zhang, Feifan; Zhou, Zengxiang; Zhai, Chao

    2015-10-01

    Mask exchange system is the main part of Multi-Object Broadband Imaging Echellette (MOBIE) on the Thirty Meter Telescope (TMT). According to the conception of the TMT mask exchange system, the pre-design was introduced in the paper which was based on IRB 140 robot. The stiffness model of IRB 140 in SolidWorks was analyzed under different gravity vectors for further error compensation. In order to find the right location and path planning, the robot and the mask cassette model was imported into MOBIE model to perform different schemes simulation. And obtained the initial installation position and routing. Based on these initial parameters, IRB 140 robot was operated to simulate the path and estimate the mask exchange time. Meanwhile, MATLAB and ADAMS software were used to perform simulation analysis and optimize the route to acquire the kinematics parameters and compare with the experiment results. After simulation and experimental research mentioned in the paper, the theoretical reference was acquired which could high efficient improve the structure of the mask exchange system parameters optimization of the path and precision of the robot position.

  15. Scatterometry on pelliclized masks: an option for wafer fabs

    NASA Astrophysics Data System (ADS)

    Gallagher, Emily; Benson, Craig; Higuchi, Masaru; Okumoto, Yasuhiro; Kwon, Michael; Yedur, Sanjay; Li, Shifang; Lee, Sangbong; Tabet, Milad

    2007-03-01

    Optical scatterometry-based metrology is now widely used in wafer fabs for lithography, etch, and CMP applications. This acceptance of a new metrology method occurred despite the abundance of wellestablished CD-SEM and AFM methods. It was driven by the desire to make measurements faster and with a lower cost of ownership. Over the last year, scatterometry has also been introduced in advanced mask shops for mask measurements. Binary and phase shift masks have been successfully measured at all desired points during photomask production before the pellicle is mounted. There is a significant benefit to measuring masks with the pellicle in place. From the wafer fab's perspective, through-pellicle metrology would verify mask effects on the same features that are characterized on wafer. On-site mask verification would enable quality control and trouble-shooting without returning the mask to a mask house. Another potential application is monitoring changes to mask films once the mask has been delivered to the fab (haze, oxide growth, etc.). Similar opportunities apply to the mask metrologist receiving line returns from a wafer fab. The ability to make line-return measurements without risking defect introduction is clearly attractive. This paper will evaluate the feasibility of collecting scatterometry data on pelliclized masks. We explore the effects of several different pellicle types on scatterometry measurements made with broadband light in the range of 320-780 nm. The complexity introduced by the pellicles' optical behavior will be studied.

  16. The Perceived Impact of Unstable Gaps between Academic Ability and Performance on the Self-Image of Students with Learning Disabilities

    ERIC Educational Resources Information Center

    Einat, Amela

    2017-01-01

    Disparities among the different abilities of students with learning disabilities have attracted extensive research. The attention has largely focused on how low abilities mask good or high potential intellectual level, and the resulting frustration. Correspondingly, the literature has also concentrated on the methods of detection required to…

  17. Clinical comparison of positional accuracy and stability between dedicated versus conventional masks for immobilization in cranial stereotactic radiotherapy using 6-degree-of-freedom image guidance system-integrated platform.

    PubMed

    Ohtakara, Kazuhiro; Hayashi, Shinya; Tanaka, Hidekazu; Hoshi, Hiroaki; Kitahara, Masashi; Matsuyama, Katsuya; Okada, Hitoshi

    2012-02-01

    To compare the positioning accuracy and stability of two distinct noninvasive immobilization devices, a dedicated (D-) and conventional (C-) mask, and to evaluate the applicability of a 6-degrees-of-freedom (6D) correction, especially to the C-mask, based on our initial experience with cranial stereotactic radiotherapy (SRT) using ExacTrac (ET)/Robotics integrated into the Novalis Tx platform. The D- and C-masks were the BrainLAB frameless mask system and a general thermoplastic mask used for conventional radiotherapy such as whole brain irradiation, respectively. A total of 148 fractions in 71 patients and 125 fractions in 20 patients were analyzed for the D- and C-masks, respectively. For the C-mask, 3D correction was applied to the initial 10 patients, and thereafter, 6D correction was adopted. The 6D residual errors (REs) in the initial setup, after correction (pre-treatment), and during post-treatment were measured and compared. The D-mask provided no significant benefit for initial setup. The post-treatment median 3D vector displacements (interquatile range) were 0.38 mm (0.22, 0.60) and 0.74 mm (0.49, 1.04) for the D- and C-masks, respectively (p<0.001). The post-treatment maximal translational REs were within 1 mm and 2 mm for the D- and C-masks, respectively, and notably within 1.5 mm for the C-mask with 6D correction. The pre-treatment 3D vector displacements were significantly correlated with those for post-treatment in both masks. The D-mask confers positional stability acceptable for SRT. For the C-mask, 6D correction is also recommended, and an additional setup margin of 0.5 mm to that for the D-mask would be sufficient. The tolerance levels for the pre-treatment REs should similarly be set as small as possible for both systems. Copyright © 2011 Elsevier Ireland Ltd. All rights reserved.

  18. Secondary gamma-ray production in a coded aperture mask

    NASA Technical Reports Server (NTRS)

    Owens, A.; Frye, G. M., Jr.; Hall, C. J.; Jenkins, T. L.; Pendleton, G. N.; Carter, J. N.; Ramsden, D.; Agrinier, B.; Bonfand, E.; Gouiffes, C.

    1985-01-01

    The application of the coded aperture mask to high energy gamma-ray astronomy will provide the capability of locating a cosmic gamma-ray point source with a precision of a few arc-minutes above 20 MeV. Recent tests using a mask in conjunction with drift chamber detectors have shown that the expected point spread function is achieved over an acceptance cone of 25 deg. A telescope employing this technique differs from a conventional telescope only in that the presence of the mask modifies the radiation field in the vicinity of the detection plane. In addition to reducing the primary photon flux incident on the detector by absorption in the mask elements, the mask will also be a secondary radiator of gamma-rays. The various background components in a CAMTRAC (Coded Aperture Mask Track Chamber) telescope are considered. Monte-Carlo calculations are compared with recent measurements obtained using a prototype instrument in a tagged photon beam line.

  19. Resistless lithography - selective etching of silicon with gallium doping regions

    NASA Astrophysics Data System (ADS)

    Abdullaev, D.; Milovanov, R.; Zubov, D.

    2016-12-01

    This paper presents the results for used of resistless lithography with a further reactive-ion etching (RIE) in various chemistry after local (Ga+) implantation of silicon with different doping dose and different size doped regions. We describe the different etching regimes for pattern transfer of FIB implanted Ga masks in silicon. The paper studied the influence of the implantation dose on the silicon surface, the masking effect and the mask resistance to erosion at dry etching. Based on these results we conclude about the possibility of using this method to create micro-and nanoscale silicon structures.

  20. Asymmetric multiple information cryptosystem based on chaotic spiral phase mask and random spectrum decomposition

    NASA Astrophysics Data System (ADS)

    Rafiq Abuturab, Muhammad

    2018-01-01

    A new asymmetric multiple information cryptosystem based on chaotic spiral phase mask (CSPM) and random spectrum decomposition is put forwarded. In the proposed system, each channel of secret color image is first modulated with a CSPM and then gyrator transformed. The gyrator spectrum is randomly divided into two complex-valued masks. The same procedure is applied to multiple secret images to get their corresponding first and second complex-valued masks. Finally, first and second masks of each channel are independently added to produce first and second complex ciphertexts, respectively. The main feature of the proposed method is the different secret images encrypted by different CSPMs using different parameters as the sensitive decryption/private keys which are completely unknown to unauthorized users. Consequently, the proposed system would be resistant to potential attacks. Moreover, the CSPMs are easier to position in the decoding process owing to their own centering mark on axis focal ring. The retrieved secret images are free from cross-talk noise effects. The decryption process can be implemented by optical experiment. Numerical simulation results demonstrate the viability and security of the proposed method.

  1. Numerical simulation of migration behavior of uranium ore dust particles in the human respiratory tract

    NASA Astrophysics Data System (ADS)

    Ye, Yong-jun; Yin, An-song; Li, Zhi; Lei, Bo; Ding, De-xin

    2017-04-01

    There is a certain concentration of radioactive dust particles in the air of workplace of underground uranium mines. Some small diameter particles will pass through the masks and enter the respiratory tract which will cause radiation damage to the human body. In order to study deposition regularity of uranium dust in the human respiratory tract, in this paper, we firstly use the RNG turbulence model to simulate the gas flow field in the human respiratory tract Z0 ∼ Z3 level under different respiratory intensity. Then we use DPM discrete phase model to simulate the concentration, particle size distribution, deposition rate and deposition share of uranium dust particles after being filtered through the masks in the human respiratory tract Z0 to Z3 bronchus. According to the simulation results, we have got the following conclusions: the particles’ number concentration of uranium dust after being filtered through the mask in the human respiratory tract basically decreases with the increasing of particle size under different respiratory intensities on the environment of uranium mine. In addition, the intensity of respiration and the mass concentration of particles have an important influence on the deposition rate and the deposition of particles in the respiratory tract.

  2. Comparison of experiments and computations for cold gas spraying through a mask. Part 2

    NASA Astrophysics Data System (ADS)

    Klinkov, S. V.; Kosarev, V. F.; Ryashin, N. S.

    2017-03-01

    This paper presents experimental and simulation results of cold spray coating deposition using the mask placed above the plane substrate at different distances. Velocities of aluminum (mean size 30 μm) and copper (mean size 60 μm) particles in the vicinity of the mask are determined. It was found that particle velocities have angular distribution in flow with a representative standard deviation of 1.5-2 degrees. Modeling of coating formation behind the mask with account for this distribution was developed. The results of model agree with experimental data confirming the importance of particle angular distribution for coating deposition process in the masked area.

  3. A pilot study on the use of geometrically accurate face models to replicate ex vivo N95 mask fit.

    PubMed

    Golshahi, Laleh; Telidetzki, Karla; King, Ben; Shaw, Diana; Finlay, Warren H

    2013-01-01

    To test the feasibility of replicating a face mask seal in vitro, we created 5 geometrically accurate reconstructions of the head and neck of an adult human subject using different materials. Three breathing patterns were simulated with each replica and an attached N95 mask. Quantitative fit testing on the subject and the replicas showed that none of the 5 isotropic materials used allowed duplication of the ex vivo mask seal for the specific mask-face combination studied. Copyright © 2013 Association for Professionals in Infection Control and Epidemiology, Inc. Published by Mosby, Inc. All rights reserved.

  4. Dual-echo EPI for non-equilibrium fMRI - implications of different echo combinations and masking procedures.

    PubMed

    Beissner, Florian; Baudrexel, Simon; Volz, Steffen; Deichmann, Ralf

    2010-08-15

    Dual-echo EPI is based on the acquisition of two images with different echo times per excitation, thus allowing for the calculation of purely T2(*) weighted data. The technique can be used for the measurement of functional activation whenever the prerequisite of constant equilibrium magnetization cannot be fulfilled due to variable inter-volume delays. The latter is the case when image acquisition is triggered by physiological parameters (e.g. cardiac gating) or by the subject's response. Despite its frequent application, there is currently no standardized way of combining the information obtained from the two acquired echoes. The goal of this study was to quantify the implication of different echo combination methods (quotients of echoes and quantification of T(2)(*)) and calculation modalities, either pre-smoothing data before combination or subjecting unsmoothed combined data to masking (no masking, volume-wise masking, joint masking), on the theoretically predicted signal-to-noise ratio (SNR) of the BOLD response and on activation results of two fMRI experiments using finger tapping and visual stimulation in one group (n=5) and different motor paradigms to activate motor areas in the cortex and the brainstem in another group (n=21). A significant impact of echo combination and masking procedure was found for both SNR and activation results. The recommended choice is a direct calculation of T(2)(*) values, either using joint masking on unsmoothed data, or pre-smoothing images prior to T(2)(*) calculation. This method was most beneficial in areas close to the surface of the brain or adjacent to the ventricles and may be especially relevant to brainstem fMRI. Copyright (c) 2010 Elsevier Inc. All rights reserved.

  5. Informational masking and musical training

    NASA Astrophysics Data System (ADS)

    Oxenham, Andrew J.; Fligor, Brian J.; Mason, Christine R.; Kidd, Gerald

    2003-09-01

    The relationship between musical training and informational masking was studied for 24 young adult listeners with normal hearing. The listeners were divided into two groups based on musical training. In one group, the listeners had little or no musical training; the other group was comprised of highly trained, currently active musicians. The hypothesis was that musicians may be less susceptible to informational masking, which is thought to reflect central, rather than peripheral, limitations on the processing of sound. Masked thresholds were measured in two conditions, similar to those used by Kidd et al. [J. Acoust. Soc. Am. 95, 3475-3480 (1994)]. In both conditions the signal was comprised of a series of repeated tone bursts at 1 kHz. The masker was comprised of a series of multitone bursts, gated with the signal. In one condition the frequencies of the masker were selected randomly for each burst; in the other condition the masker frequencies were selected randomly for the first burst of each interval and then remained constant throughout the interval. The difference in thresholds between the two conditions was taken as a measure of informational masking. Frequency selectivity, using the notched-noise method, was also estimated in the two groups. The results showed no difference in frequency selectivity between the two groups, but showed a large and significant difference in the amount of informational masking between musically trained and untrained listeners. This informational masking task, which requires no knowledge specific to musical training (such as note or interval names) and is generally not susceptible to systematic short- or medium-term training effects, may provide a basis for further studies of analytic listening abilities in different populations.

  6. A Parallel Vector Machine for the PM Programming Language

    NASA Astrophysics Data System (ADS)

    Bellerby, Tim

    2016-04-01

    PM is a new programming language which aims to make the writing of computational geoscience models on parallel hardware accessible to scientists who are not themselves expert parallel programmers. It is based around the concept of communicating operators: language constructs that enable variables local to a single invocation of a parallelised loop to be viewed as if they were arrays spanning the entire loop domain. This mechanism enables different loop invocations (which may or may not be executing on different processors) to exchange information in a manner that extends the successful Communicating Sequential Processes idiom from single messages to collective communication. Communicating operators avoid the additional synchronisation mechanisms, such as atomic variables, required when programming using the Partitioned Global Address Space (PGAS) paradigm. Using a single loop invocation as the fundamental unit of concurrency enables PM to uniformly represent different levels of parallelism from vector operations through shared memory systems to distributed grids. This paper describes an implementation of PM based on a vectorised virtual machine. On a single processor node, concurrent operations are implemented using masked vector operations. Virtual machine instructions operate on vectors of values and may be unmasked, masked using a Boolean field, or masked using an array of active vector cell locations. Conditional structures (such as if-then-else or while statement implementations) calculate and apply masks to the operations they control. A shift in mask representation from Boolean to location-list occurs when active locations become sufficiently sparse. Parallel loops unfold data structures (or vectors of data structures for nested loops) into vectors of values that may additionally be distributed over multiple computational nodes and then split into micro-threads compatible with the size of the local cache. Inter-node communication is accomplished using standard OpenMP and MPI. Performance analyses of the PM vector machine, demonstrating its scaling properties with respect to domain size and the number of processor nodes will be presented for a range of hardware configurations. The PM software and language definition are being made available under unrestrictive MIT and Creative Commons Attribution licenses respectively: www.pm-lang.org.

  7. Building a stronger child dental health system in Australia: statistical sampling masks the burden of dental disease distribution in Australian children.

    PubMed

    Tennant, M; Kruger, E

    2014-01-01

    In Australia, over the past 30 years, the prevalence of dental decay in children has reduced significantly, where today 60-70% of all 12-year-olds are caries free, and only 10% of children have more than two decayed teeth. However, many studies continue to report a small but significant subset of children suffering severe levels of decay. The present study applies Monte Carlo simulation to examine, at the national level, 12-year-old decayed, missing or filled teeth and shed light on both the statistical limitation of Australia's reporting to date as well as the problem of targeting high-risk children. A simulation for 273 000 Australian 12-year-old children found that moving from different levels of geographic clustering produced different statistical influences that drive different conclusions. At the high scale (ie state level) the gross averaging of the non-normally distributed disease burden masks the small subset of disease bearing children. At the much higher acuity of analysis (ie local government area) the risk of low numbers in the sample becomes a significant issue. The results clearly highlight the importance of care when examining the existing data, and, second, opportunities for far greater levels of targeting of services to children in need. The sustainability (and fairness) of universal coverage systems needs to be examined to ensure they remain highly targeted at disease burden, and not just focused on the children that are easy to reach (and suffer the least disease).

  8. Accurate GM atrophy quantification in MS using lesion-filling with co-registered 2D lesion masks☆

    PubMed Central

    Popescu, V.; Ran, N.C.G.; Barkhof, F.; Chard, D.T.; Wheeler-Kingshott, C.A.; Vrenken, H.

    2014-01-01

    Background In multiple sclerosis (MS), brain atrophy quantification is affected by white matter lesions. LEAP and FSL-lesion_filling, replace lesion voxels with white matter intensities; however, they require precise lesion identification on 3DT1-images. Aim To determine whether 2DT2 lesion masks co-registered to 3DT1 images, yield grey and white matter volumes comparable to precise lesion masks. Methods 2DT2 lesion masks were linearly co-registered to 20 3DT1-images of MS patients, with nearest-neighbor (NNI), and tri-linear interpolation. As gold-standard, lesion masks were manually outlined on 3DT1-images. LEAP and FSL-lesion_filling were applied with each lesion mask. Grey (GM) and white matter (WM) volumes were quantified with FSL-FAST, and deep gray matter (DGM) volumes using FSL-FIRST. Volumes were compared between lesion mask types using paired Wilcoxon tests. Results Lesion-filling with gold-standard lesion masks compared to native images reduced GM overestimation by 1.93 mL (p < .001) for LEAP, and 1.21 mL (p = .002) for FSL-lesion_filling. Similar effects were achieved with NNI lesion masks from 2DT2. Global WM underestimation was not significantly influenced. GM and WM volumes from NNI, did not differ significantly from gold-standard. GM segmentation differed between lesion masks in the lesion area, and also elsewhere. Using the gold-standard, FSL-FAST quantified as GM on average 0.4% of the lesion area with LEAP and 24.5% with FSL-lesion_filling. Lesion-filling did not influence DGM volumes from FSL-FIRST. Discussion These results demonstrate that for global GM volumetry, precise lesion masks on 3DT1 images can be replaced by co-registered 2DT2 lesion masks. This makes lesion-filling a feasible method for GM atrophy measurements in MS. PMID:24567908

  9. SU-D-18C-02: Feasibility of Using a Short ASL Scan for Calibrating Cerebral Blood Flow Obtained From DSC-MRI

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Wang, P; Chang, T; Huang, K

    2014-06-01

    Purpose: This study aimed to evaluate the feasibility of using a short arterial spin labeling (ASL) scan for calibrating the dynamic susceptibility contrast- (DSC-) MRI in a group of patients with internal carotid artery stenosis. Methods: Six patients with unilateral ICA stenosis enrolled in the study on a 3T clinical MRI scanner. The ASL-cerebral blood flow (-CBF) maps were calculated by averaging different number of dynamic points (N=1-45) acquired by using a Q2TIPS sequence. For DSC perfusion analysis, arterial input function was selected to derive the relative cerebral blood flow (rCBF) map and the delay (Tmax) map. Patient-specific CF wasmore » calculated from the mean ASL- and DSC-CBF obtained from three different masks: (1)Tmax< 3s, (2)combined gray matter mask with mask 1, (3)mask 2 with large vessels removed. One CF value was created for each number of averages by using each of the three masks for calibrating the DSC-CBF map. The CF value of the largest number of averages (NL=45) was used to determine the acceptable range(< 10%, <15%, and <20%) of CF values corresponding to the minimally acceptable number of average (NS) for each patient. Results: Comparing DSC CBF maps corrected by CF values of NL (CBFL) in ACA, MCA and PCA territories, all masks resulted in smaller CBF on the ipsilateral side than the contralateral side of the MCA territory(p<.05). The values obtained from mask 1 were significantly different than the mask 3(p<.05). Using mask 3, the medium values of Ns were 4(<10%), 2(<15%) and 2(<20%), with the worst case scenario (maximum Ns) of 25, 4, and 4, respectively. Conclusion: This study found that reliable calibration of DSC-CBF can be achieved from a short pulsed ASL scan. We suggested use a mask based on the Tmax threshold, the inclusion of gray matter only and the exclusion of large vessels for performing the calibration.« less

  10. Management of birth asphyxia in home deliveries in rural Gadchiroli: the effect of two types of birth attendants and of resuscitating with mouth-to-mouth, tube-mask or bag-mask.

    PubMed

    Bang, Abhay T; Bang, Rani A; Baitule, Sanjay B; Reddy, Hanimi M; Deshmukh, Mahesh D

    2005-03-01

    To evaluate the effect of home-based neonatal care on birth asphyxia and to compare the effectiveness of two types of workers and three methods of resuscitation in home delivery. In a field trial of home-based neonatal care in rural Gadchiroli, India, birth asphyxia in home deliveries was managed differently during different phases. Trained traditional birth attendants (TBA) used mouth-to-mouth resuscitation in the baseline years (1993 to 1995). Additional village health workers (VHWs) only observed in 1995 to 1996. In the intervention years (1996 to 2003), they used tube-mask (1996 to 1999) and bag-mask (1999 to 2003). The incidence, case fatality (CF) and asphyxia-specific mortality rate (ASMR) during different phases were compared. During the intervention years, 5033 home deliveries occurred. VHWs were present during 84% home deliveries. The incidence of mild birth asphyxia decreased by 60%, from 14% in the observation year (1995 to 1996) to 6% in the intervention years (p<0.0001). The incidence of severe asphyxia did not change significantly, but the CF in neonates with severe asphyxia decreased by 47.5%, from 39 to 20% (p<0.07) and ASMR by 65%, from 11 to 4% (p<0.02). Mouth-to-mouth resuscitation reduced the ASMR by 12%, tube-mask further reduced the CF by 27% and the ASMR by 67%. The bag-mask showed an additional decrease in CF of 39% and in the fresh stillbirth rate of 33% in comparison to tube-mask (not significant). The cost of bag and mask was US dollars 13 per averted death. Oxytocic injection administered by unqualified doctors showed an odds ratio of three for the occurrence of severe asphyxia or fresh stillbirth. Home-based interventions delivered by a team of TBA and a semiskilled VHW reduced the asphyxia-related neonatal mortality by 65% compared to only TBA. The bag-mask appears to be superior to tube-mask or mouth-to-mouth resuscitation, with an estimated equipment cost of US dollars 13 per death averted.

  11. Design and Implementation of a Video-Zoom Driven Digital Audio-Zoom System for Portable Digital Imaging Devices

    NASA Astrophysics Data System (ADS)

    Park, Nam In; Kim, Seon Man; Kim, Hong Kook; Kim, Ji Woon; Kim, Myeong Bo; Yun, Su Won

    In this paper, we propose a video-zoom driven audio-zoom algorithm in order to provide audio zooming effects in accordance with the degree of video-zoom. The proposed algorithm is designed based on a super-directive beamformer operating with a 4-channel microphone system, in conjunction with a soft masking process that considers the phase differences between microphones. Thus, the audio-zoom processed signal is obtained by multiplying an audio gain derived from a video-zoom level by the masked signal. After all, a real-time audio-zoom system is implemented on an ARM-CORETEX-A8 having a clock speed of 600 MHz after different levels of optimization are performed such as algorithmic level, C-code, and memory optimizations. To evaluate the complexity of the proposed real-time audio-zoom system, test data whose length is 21.3 seconds long is sampled at 48 kHz. As a result, it is shown from the experiments that the processing time for the proposed audio-zoom system occupies 14.6% or less of the ARM clock cycles. It is also shown from the experimental results performed in a semi-anechoic chamber that the signal with the front direction can be amplified by approximately 10 dB compared to the other directions.

  12. Anticipating and controlling mask costs within EDA physical design

    NASA Astrophysics Data System (ADS)

    Rieger, Michael L.; Mayhew, Jeffrey P.; Melvin, Lawrence S.; Lugg, Robert M.; Beale, Daniel F.

    2003-08-01

    For low k1 lithography, more aggressive OPC is being applied to critical layers, and the number of mask layers with OPC treatments is growing rapidly. The 130 nm, process node required, on average, 8 layers containing rules- or model-based OPC. The 90 nm node will have 16 OPC layers, of which 14 layers contain aggressive model-based OPC. This escalation of mask pattern complexity, coupled with the predominant use of vector-scan e-beam (VSB) mask writers contributes to the rising costs of advanced mask sets. Writing times for OPC layouts are several times longer than for traditional layouts, making mask exposure the single largest cost component for OPC masks. Lower mask yields, another key factor in higher mask costs, is also aggravated by OPC. Historical mask set costs are plotted below. The initial cost of a 90 nm-node mask set will exceed one million dollars. The relative impact of mask cost on chip depends on how many total wafers are printed with each mask set. For many foundry chips, where unit production is often well below 1000 wafers, mask costs are larger than wafer processing costs. Further increases in NRE may begin to discourage these suppliers' adoption to 90 nm and smaller nodes. In this paper we will outline several alternatives for reducing mask costs by strategically leveraging dimensional margins. Dimensional specifications for a particular masking layer usually are applied uniformly to all features on that layer. As a practical matter, accuracy requirements on different features in the design may vary widely. Take a polysilicon layer, for example: global tolerance specifications for that layer are driven by the transistor-gate requirements; but these parameters over-specify interconnect feature requirements. By identifying features where dimensional accuracy requirements can be reduced, additional margin can be leveraged to reduce OPC complexity. Mask writing time on VSB tools will drop in nearly direct proportion to reduce shot count. By inspecting masks with reference to feature-dependent margins, instead of uniform specifications, mask yield can be effectively increased further reducing delivered mask expense.

  13. Recognition of speech in noise after application of time-frequency masks: Dependence on frequency and threshold parameters

    PubMed Central

    Sinex, Donal G.

    2013-01-01

    Binary time-frequency (TF) masks can be applied to separate speech from noise. Previous studies have shown that with appropriate parameters, ideal TF masks can extract highly intelligible speech even at very low speech-to-noise ratios (SNRs). Two psychophysical experiments provided additional information about the dependence of intelligibility on the frequency resolution and threshold criteria that define the ideal TF mask. Listeners identified AzBio Sentences in noise, before and after application of TF masks. Masks generated with 8 or 16 frequency bands per octave supported nearly-perfect identification. Word recognition accuracy was slightly lower and more variable with 4 bands per octave. When TF masks were generated with a local threshold criterion of 0 dB SNR, the mean speech reception threshold was −9.5 dB SNR, compared to −5.7 dB for unprocessed sentences in noise. Speech reception thresholds decreased by about 1 dB per dB of additional decrease in the local threshold criterion. Information reported here about the dependence of speech intelligibility on frequency and level parameters has relevance for the development of non-ideal TF masks for clinical applications such as speech processing for hearing aids. PMID:23556604

  14. Phonologically-Based Priming in the Same-Different Task With L1 Readers.

    PubMed

    Lupker, Stephen J; Nakayama, Mariko; Yoshihara, Masahiro

    2018-02-01

    The present experiment provides an investigation of a promising new tool, the masked priming same-different task, for investigating the orthographic coding process. Orthographic coding is the process of establishing a mental representation of the letters and letter order in the word being read which is then used by readers to access higher-level (e.g., semantic) information about that word. Prior research (e.g., Norris & Kinoshita, 2008) had suggested that performance in this task may be based entirely on orthographic codes. As reported by Lupker, Nakayama, and Perea (2015a), however, in at least some circumstances, phonological codes also play a role. Specifically, even though their 2 languages are completely different orthographically, Lupker et al.'s Japanese-English bilinguals showed priming in this task when masked L1 primes were phonologically similar to L2 targets. An obvious follow-up question is whether Lupker et al.'s effect might have resulted from a strategy that was adopted by their bilinguals to aid in processing of, and memory for, the somewhat unfamiliar L2 targets. In the present experiment, Japanese readers responded to (Japanese) Kanji targets with phonologically identical primes (on "related" trials) being presented in a completely different but highly familiar Japanese script, Hiragana. Once again, significant priming effects were observed, indicating that, although performance in the masked priming same-different task may be mainly based on orthographic codes, phonological codes can play a role even when the stimuli being matched are familiar words from a reader's L1. (PsycINFO Database Record (c) 2018 APA, all rights reserved).

  15. Tinnitus pitch and minimum masking levels in different etiologies.

    PubMed

    Zagólski, Olaf; Stręk, Paweł

    2014-07-01

    We sought to determine whether the results of audiological tests and tinnitus characteristics, particularly tinnitus pitch and minimum masking level (MML), depend on tinnitus etiology, and what other etiology-specific tinnitus characteristics there are. The patients answered questions concerning tinnitus laterality, duration, character, aggravation, alleviation, previous treatment, and circumstances of onset. The results of tympanometry, pure-tone audiometry, distortion-product otoacoustic emissions, tinnitus likeness spectrum, MML, and uncomfortable loudness level were evaluated. Patients with several tinnitus etiological factors were excluded. The remaining participants were divided into groups according to medical history: acute acoustic trauma: 67 ears; chronic acoustic trauma: 82; prolonged use of oral estrogen and progesterone contraceptives: 46; Ménière's disease: 25; congenital hearing loss: 19; sensorineural sudden deafness: 40; dull head trauma: 19; viral labyrinthitis: 53; stroke: 6; presbycusis: 152. Data of 509 ears were analysed. Tinnitus pitch was highest in patients with acute acoustic trauma and lowest in patients receiving estrogen and progesterone. MML was lowest after acute acoustic trauma and in congenital hearing loss, and highest after a stroke and in the case of presbytinnitus. Tinnitus pitch and MML are etiology dependent.

  16. Simulation-based MDP verification for leading-edge masks

    NASA Astrophysics Data System (ADS)

    Su, Bo; Syrel, Oleg; Pomerantsev, Michael; Hagiwara, Kazuyuki; Pearman, Ryan; Pang, Leo; Fujimara, Aki

    2017-07-01

    For IC design starts below the 20nm technology node, the assist features on photomasks shrink well below 60nm and the printed patterns of those features on masks written by VSB eBeam writers start to show a large deviation from the mask designs. Traditional geometry-based fracturing starts to show large errors for those small features. As a result, other mask data preparation (MDP) methods have become available and adopted, such as rule-based Mask Process Correction (MPC), model-based MPC and eventually model-based MDP. The new MDP methods may place shot edges slightly differently from target to compensate for mask process effects, so that the final patterns on a mask are much closer to the design (which can be viewed as the ideal mask), especially for those assist features. Such an alteration generally produces better masks that are closer to the intended mask design. Traditional XOR-based MDP verification cannot detect problems caused by eBeam effects. Much like model-based OPC verification which became a necessity for OPC a decade ago, we see the same trend in MDP today. Simulation-based MDP verification solution requires a GPU-accelerated computational geometry engine with simulation capabilities. To have a meaningful simulation-based mask check, a good mask process model is needed. The TrueModel® system is a field tested physical mask model developed by D2S. The GPU-accelerated D2S Computational Design Platform (CDP) is used to run simulation-based mask check, as well as model-based MDP. In addition to simulation-based checks such as mask EPE or dose margin, geometry-based rules are also available to detect quality issues such as slivers or CD splits. Dose margin related hotspots can also be detected by setting a correct detection threshold. In this paper, we will demonstrate GPU-acceleration for geometry processing, and give examples of mask check results and performance data. GPU-acceleration is necessary to make simulation-based mask MDP verification acceptable.

  17. Cross-Language Differences in Informational Masking of Speech by Speech: English versus Mandarin Chinese

    ERIC Educational Resources Information Center

    Wu, Xihong; Yang, Zhigang; Huang, Ying; Chen, Jing; Li, Liang; Daneman, Meredyth; Schneider, Bruce A.

    2011-01-01

    Purpose: The purpose of the study was to determine why perceived spatial separation provides a greater release from informational masking in Chinese than English when target sentences in each of the languages are masked by other talkers speaking the same language. Method: Monolingual speakers of English and Mandarin Chinese listened to…

  18. A multi-focus image fusion method via region mosaicking on Laplacian pyramids

    PubMed Central

    Kou, Liang; Zhang, Liguo; Sun, Jianguo; Han, Qilong; Jin, Zilong

    2018-01-01

    In this paper, a method named Region Mosaicking on Laplacian Pyramids (RMLP) is proposed to fuse multi-focus images that is captured by microscope. First, the Sum-Modified-Laplacian is applied to measure the focus of multi-focus images. Then the density-based region growing algorithm is utilized to segment the focused region mask of each image. Finally, the mask is decomposed into a mask pyramid to supervise region mosaicking on a Laplacian pyramid. The region level pyramid keeps more original information than the pixel level. The experiment results show that RMLP has best performance in quantitative comparison with other methods. In addition, RMLP is insensitive to noise and can reduces the color distortion of the fused images on two datasets. PMID:29771912

  19. Speech-on-speech masking with variable access to the linguistic content of the masker speech for native and non-native speakers of English

    PubMed Central

    Calandruccio, Lauren; Bradlow, Ann R.; Dhar, Sumitrajit

    2013-01-01

    Background Masking release for an English sentence-recognition task in the presence of foreign-accented English speech compared to native-accented English speech was reported in Calandruccio, Dhar and Bradlow (2010). The masking release appeared to increase as the masker intelligibility decreased. However, it could not be ruled out that spectral differences between the speech maskers were influencing the significant differences observed. Purpose The purpose of the current experiment was to minimize spectral differences between speech maskers to determine how various amounts of linguistic information within competing speech affect masking release. Research Design A mixed model design with within- (four two-talker speech maskers) and between-subject (listener group) factors was conducted. Speech maskers included native-accented English speech, and high-intelligibility, moderate-intelligibility and low-intelligibility Mandarin-accented English. Normalizing the long-term average speech spectra of the maskers to each other minimized spectral differences between the masker conditions. Study Sample Three listener groups were tested including monolingual English speakers with normal hearing, non-native speakers of English with normal hearing, and monolingual speakers of English with hearing loss. The non-native speakers of English were from various native-language backgrounds, not including Mandarin (or any other Chinese dialect). Listeners with hearing loss had symmetrical, mild sloping to moderate sensorineural hearing loss. Data Collection and Analysis Listeners were asked to repeat back sentences that were presented in the presence of four different two-talker speech maskers. Responses were scored based on the keywords within the sentences (100 keywords/masker condition). A mixed-model regression analysis was used to analyze the difference in performance scores between the masker conditions and the listener groups. Results Monolingual speakers of English with normal hearing benefited when the competing speech signal was foreign-accented compared to native-accented allowing for improved speech recognition. Various levels of intelligibility across the foreign-accented speech maskers did not influence results. Neither the non-native English listeners with normal hearing, nor the monolingual English speakers with hearing loss benefited from masking release when the masker was changed from native-accented to foreign-accented English. Conclusions Slight modifications between the target and the masker speech allowed monolingual speakers of English with normal hearing to improve their recognition of native-accented English even when the competing speech was highly intelligible. Further research is needed to determine which modifications within the competing speech signal caused the Mandarin-accented English to be less effective with respect to masking. Determining the influences within the competing speech that make it less effective as a masker, or determining why monolingual normal-hearing listeners can take advantage of these differences could help improve speech recognition for those with hearing loss in the future. PMID:25126683

  20. A backwards glance at words: Using reversed-interior masked primes to test models of visual word identification

    PubMed Central

    Lupker, Stephen J.

    2017-01-01

    The experiments reported here used “Reversed-Interior” (RI) primes (e.g., cetupmor-COMPUTER) in three different masked priming paradigms in order to test between different models of orthographic coding/visual word recognition. The results of Experiment 1, using a standard masked priming methodology, showed no evidence of priming from RI primes, in contrast to the predictions of the Bayesian Reader and LTRS models. By contrast, Experiment 2, using a sandwich priming methodology, showed significant priming from RI primes, in contrast to the predictions of open bigram models, which predict that there should be no orthographic similarity between these primes and their targets. Similar results were obtained in Experiment 3, using a masked prime same-different task. The results of all three experiments are most consistent with the predictions derived from simulations of the Spatial-coding model. PMID:29244824

  1. Comparison of cloud optical depth and cloud mask applying BRDF model-based background surface reflectance

    NASA Astrophysics Data System (ADS)

    Kim, H. W.; Yeom, J. M.; Woo, S. H.

    2017-12-01

    Over the thin cloud region, satellite can simultaneously detect the reflectance from thin clouds and land surface. Since the mixed reflectance is not the exact cloud information, the background surface reflectance should be eliminated to accurately distinguish thin cloud such as cirrus. In the previous research, Kim et al (2017) was developed the cloud masking algorithm using the Geostationary Ocean Color Imager (GOCI), which is one of significant instruments for Communication, Ocean, and Meteorology Satellite (COMS). Although GOCI has 8 spectral channels including visible and near infra-red spectral ranges, the cloud masking has quantitatively reasonable result when comparing with MODIS cloud mask (Collection 6 MYD35). Especially, we noticed that this cloud masking algorithm is more specialized in thin cloud detections through the validation with Cloud-Aerosol Lidar and Infrared Pathfinder Satellite Observation (CALIPSO) data. Because this cloud masking method was concentrated on eliminating background surface effects from the top-of-atmosphere (TOA) reflectance. Applying the difference between TOA reflectance and the bi-directional reflectance distribution function (BRDF) model-based background surface reflectance, cloud areas both thick cloud and thin cloud can be discriminated without infra-red channels which were mostly used for detecting clouds. Moreover, when the cloud mask result was utilized as the input data when simulating BRDF model and the optimized BRDF model-based surface reflectance was used for the optimized cloud masking, the probability of detection (POD) has higher value than POD of the original cloud mask. In this study, we examine the correlation between cloud optical depth (COD) and its cloud mask result. Cloud optical depths mostly depend on the cloud thickness, the characteristic of contents, and the size of cloud contents. COD ranges from less than 0.1 for thin clouds to over 1000 for the huge cumulus due to scattering by droplets. With the cloud optical depth of CALIPSO, the cloud masking result can be more improved since we can figure out how deep cloud is. To validate the cloud mask and the correlation result, the atmospheric retrieval will be computed to compare the difference between TOA reflectance and the simulated surface reflectance.

  2. [Patients' reaction to pharmacists wearing a mask during their consultations].

    PubMed

    Tamura, Eri; Kishimoto, Keiko; Fukushima, Noriko

    2013-01-01

      This study sought to determine the effect of pharmacists wearing a mask on the consultation intention of patients who do not have a trusting relationship with the pharmacists. We conducted a questionnaire survey of customers at a Tokyo drugstore in August 2012. Subjects answered a questionnaire after watching two medical teaching videos, one in which the pharmacist was wearing a mask and the other in which the pharmacist was not wearing a mask. Data analysis was performed using a paired t-test and multiple logistic regression. The paired t-test revealed a significant difference in 'Maintenance Problem' between the two pharmacist situations. After excluding factors not associated with wearing a mask, multiple logistic regression analysis identified three independent variables with a significant effect on participants not wanting to consult with a pharmacist wearing a mask. Positive factors were 'active-inactive' and 'frequency mask use', a negative factor was 'age'. Our study has shown that pharmacists wearing a mask may be a factor that prevents patients from consulting with pharmacist. Those patients whose intention to consult might be affected by the pharmacists wearing a mask tended to be younger, to have no habit of wearing masks preventively themselves, and to form a negative opinion of such pharmacists. Therefore, it was estimated that pharmacists who wear masks need to provide medical education by asking questions more positively than when they do not wear a mask in order to prevent the patient worrying about oneself.

  3. PMJ panel discussion overview on mask complexities, cost, and cycle time in 32-nm system LSI generation: conflict or concurrent?

    NASA Astrophysics Data System (ADS)

    Hosono, Kunihiro; Kato, Kokoro

    2008-10-01

    This is a report on a panel discussion organized in Photomask Japan 2008, where the challenges about "Mask Complexities, Cost, and Cycle Time in 32-nm System LSI Generation" were addressed to have a look over the possible solutions from the standpoints of chipmaker, commercial mask shop, DA tool vendor and equipments makers. The wrap-up is as follows: Mask complexities justify the mask cost, while the acceptable increase rate of 32nm-mask cost significantly differs between mask suppliers or users side. The efficiency progress by new tools or DFM has driven their cycle-time reductions. Mask complexities and cost will be crucial issues prior to cycle time, and there seems to be linear correlation between them. Controlling complexity and cycle time requires developing a mix of advanced technologies, and especially for cost reduction, shot prices in writers and processing rates in inspection tools have been improved remarkably by tool makers. In addition, activities of consortium in Japan (Mask D2I) are expected to enhance the total optimization of mask design, writing and inspection. The cycle-time reduction potentially drives the lowering of mask cost, and, on the other, the pattern complexities and tighter mask specifications get in the way to 32nm generation as well as the nano-economics and market challenges. There are still many difficult problems in mask manufacturing now, and we are sure to go ahead to overcome a 32nm hurdle with the advances of technologies and collaborations by not only technologies but also finance.

  4. Non-invasive primate head restraint using thermoplastic masks

    PubMed Central

    Drucker, Caroline B.; Carlson, Monica L.; Toda, Koji; DeWind, Nicholas K.; Platt, Michael L.

    2015-01-01

    Background The success of many neuroscientific studies depends upon adequate head fixation of awake, behaving animals. Typically, this is achieved by surgically affixing a head-restraint prosthesis to the skull. New Method Here we report the use of thermoplastic masks to non-invasively restrain monkeys’ heads. Mesh thermoplastic sheets become pliable when heated and can then be molded to an individual monkey’s head. After cooling, the custom mask retains this shape indefinitely for day-to-day use. Results We successfully trained rhesus macaques (Macaca mulatta) to perform cognitive tasks while wearing thermoplastic masks. Using these masks, we achieved a level of head stability sufficient for high-resolution eye-tracking and intracranial electrophysiology. Comparison with Existing Method Compared with traditional head-posts, we find that thermoplastic masks perform at least as well during infrared eye-tracking and single-neuron recordings, allow for clearer magnetic resonance image acquisition, enable freer placement of a transcranial magnetic stimulation coil, and impose lower financial and time costs on the lab. Conclusions We conclude that thermoplastic masks are a viable non-invasive form of primate head restraint that enable a wide range of neuroscientific experiments. PMID:26112334

  5. Status of EUVL mask development in Europe (Invited Paper)

    NASA Astrophysics Data System (ADS)

    Peters, Jan H.

    2005-06-01

    EUV lithography is the prime candidate for the next generation lithography technology after 193 nm immersion lithography. The commercial onset for this technology is expected for the 45 nm half-pitch technology or below. Several European and national projects and quite a large number of companies and research institutions in Europe work on various aspects of the technological challenges to make EUV a commercially viable technology in the not so far future. Here the development of EUV sources, the development of an EUV exposure tools, metrology tools dedicated for characterization of mask, the production of EUV mask blanks and the mask structuring itself are the key areas in which major activities can be found. In this talk we will primarily focus on those activities, which are related to establish an EUV mask supply chain with all its ingredients from substrate production, polishing, deposition of EUV layers, blank characterization, mask patterning process and the consecutive metrology and defect inspection as well as shipping and handling from blank supply to usage in the wafer fab. The EUV mask related projects on the national level are primarily supported by the French Ministry of Economics and Finance (MinEFi) and the German Ministry of Education and Research (BMBF).

  6. Masked translation priming effects with low proficient bilinguals.

    PubMed

    Dimitropoulou, Maria; Duñabeitia, Jon Andoni; Carreiras, Manuel

    2011-02-01

    Non-cognate masked translation priming lexical decision studies with unbalanced bilinguals suggest that masked translation priming effects are asymmetric as a function of the translation direction (significant effects only in the dominant [L1] to nondominant [L2] language translation direction). However, in contrast to the predictions of most current accounts of masked translation priming effects, bidirectional effects have recently been reported with a group of low proficient bilinguals Duyck & Warlop 2009 (Experimental Psychology 56:173-179). In a series of masked translation priming lexical decision experiments we examined whether the same pattern of effects would emerge with late and low proficient Greek (L1)-Spanish (L2) bilinguals. Contrary to the results obtained by Duyck and Warlop, and in line with the results found in most studies in the masked priming literature, significant translation priming effects emerged only when the bilinguals performed the task with L1 primes and L2 targets. The existence of the masked translation priming asymmetry with low proficient bilinguals suggests that cross-linguistic automatic lexico-semantic links may be established very early in the process of L2 acquisition. These findings could help to define models of bilingualism that consider L2 proficiency level to be a determining factor.

  7. ScAlN etch mask for highly selective silicon etching

    DOE PAGES

    Henry, Michael David; Young, Travis R.; Griffin, Ben

    2017-09-08

    Here, this work reports the utilization of a recently developed film, ScAlN, as a silicon etch mask offering significant improvements in high etch selectivity to silicon. Utilization of ScAlN as a fluorine chemistry based deep reactive ion etch mask demonstrated etch selectivity at 23 550:1, four times better than AlN, 11 times better than Al 2O 3, and 148 times better than silicon dioxide with significantly less resputtering at high bias voltage than either Al 2O 3 or AlN. Ellipsometry film thickness measurements show less than 0.3 nm/min mask erosion rates for ScAlN. Micromasking of resputtered Al for Al 2Omore » 3, AlN, and ScAlN etch masks is also reported here, utilizing cross-sectional scanning electron microscope and confocal microscope roughness measurements. With lower etch bias, the reduced etch rate can be optimized to achieve a trench bottom surface roughness that is comparable to SiO 2 etch masks. Etch mask selectivity enabled by ScAlN is likely to make significant improvements in microelectromechanical systems, wafer level packaging, and plasma dicing of silicon.« less

  8. Self-masking: Listening during vocalization. Normal hearing.

    PubMed

    Borg, Erik; Bergkvist, Christina; Gustafsson, Dan

    2009-06-01

    What underlying mechanisms are involved in the ability to talk and listen simultaneously and what role does self-masking play under conditions of hearing impairment? The purpose of the present series of studies is to describe a technique for assessment of masked thresholds during vocalization, to describe normative data for males and females, and to focus on hearing impairment. The masking effect of vocalized [a:] on narrow-band noise pulses (250-8000 Hz) was studied using the maximum vocalization method. An amplitude-modulated series of sound pulses, which sounded like a steam engine, was masked until the criterion of halving the perceived pulse rate was reached. For masking of continuous reading, a just-follow-conversation criterion was applied. Intra-session test-retest reproducibility and inter-session variability were calculated. The results showed that female voices were more efficient in masking high frequency noise bursts than male voices and more efficient in masking both a male and a female test reading. The male had to vocalize 4 dBA louder than the female to produce the same masking effect on the test reading. It is concluded that the method is relatively simple to apply and has small intra-session and fair inter-session variability. Interesting gender differences were observed.

  9. Facial and ocular deposition of nebulized budesonide: effects of face mask design.

    PubMed

    Harris, Keith W; Smaldone, Gerald C

    2008-02-01

    In vivo case reports and in vitro studies have indicated that aerosol therapy using face masks can result in drug deposition on the face and in the eyes, and that face mask design may affect drug delivery. To test different mask/nebulizer combinations for budesonide, a nebulized steroid used to treat pediatric patients with asthma. Using high-performance liquid chromatography, drug delivery (inhaled mass), facial, and ocular deposition of budesonide aerosols were studied in vitro using a ventilated face facsimile (tidal volume, 50 mL; rate, 25 breaths/min, duty cycle 0.4), a tight-fitting test mask, a standard commercial mask, and a prototype mask designed to optimize delivery by reducing particle inertia. Nebulizer insertion into the mask (front loaded vs bottom loaded) was also tested. Particle size was measured by cascade impaction. Pari LC Plus (PARI Respiratory Equipment; Midlothian, VA) and MistyNeb (Allegiance; McGaw Park, IL) nebulizers were tested. Inhaled mass for tight-fitting and prototype masks was similar (13.2 +/- 1.85% vs 14.4 +/- 0.67% [percentage of nebulizer charge], p = 0.58) and significantly greater than for the commercial mask (3.03 +/- 0.26%, p = 0.005). Mask insertion of nebulizer was a key factor (inhaled mass: front loaded vs bottom loaded, 8.23 +/- 0.18% vs 3.03 +/- 0.26%; p = 0.005). Ocular deposition varied by an order of magnitude and was a strong function of mask design (4.77 +/- 0.24% vs 0.35 +/- 0.05%, p = 0.002, tight fitting vs prototype). Particle sizes (7.3 to 9 microm) were larger than previously reported for budesonide. For pediatric breathing patterns, mask design is a key factor defining budesonide delivery to the lungs, face, and eyes. Front-loaded nebulizer mask combinations are more efficient than bottom-loaded systems.

  10. Multi-shaped beam: development status and update on lithography results

    NASA Astrophysics Data System (ADS)

    Slodowski, Matthias; Doering, Hans-Joachim; Dorl, Wolfgang; Stolberg, Ines A.

    2011-04-01

    According to the ITRS [1] photo mask is a significant challenge for the 22nm technology node requirements and beyond. Mask making capability and cost escalation continue to be critical for future lithography progress. On the technological side mask specifications and complexity have increased more quickly than the half-pitch requirements on the wafer designated by the roadmap due to advanced optical proximity correction and double patterning demands. From the economical perspective mask costs have significantly increased each generation, in which mask writing represents a major portion. The availability of a multi-electron-beam lithography system for mask write application is considered a potential solution to overcome these challenges [2, 3]. In this paper an update of the development status of a full-package high-throughput multi electron-beam writer, called Multi Shaped Beam (MSB), will be presented. Lithography performance results, which are most relevant for mask writing applications, will be disclosed. The MSB technology is an evolutionary development of the matured single Variable Shaped Beam (VSB) technology. An arrangement of Multi Deflection Arrays (MDA) allows operation with multiple shaped beams of variable size, which can be deflected and controlled individually [4]. This evolutionary MSB approach is associated with a lower level of risk and a relatively short time to implementation compared to the known revolutionary concepts [3, 5, 6]. Lithography performance is demonstrated through exposed pattern. Further details of the substrate positioning platform performance will be disclosed. It will become apparent that the MSB operational mode enables lithography on the same and higher performance level compared to single VSB and that there are no specific additional lithography challenges existing beside those which have already been addressed [1].

  11. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Upadhyaya, Mihir; Jindal, Vibhu; Basavalingappa, Adarsh

    The availability of defect-free masks is considered to be a critical issue for enabling extreme ultraviolet lithography (EUVL) as the next generation technology. Since completely defect-free masks will be hard to achieve, it is essential to have a good understanding of the printability of the native EUV mask defects. In this work, we performed a systematic study of native mask defects to understand the defect printability caused by them. The multilayer growth over native substrate mask blank defects was correlated to the multilayer growth over regular-shaped defects having similar profiles in terms of their width and height. To model themore » multilayer growth over the defects, a novel level-set multilayer growth model was used that took into account the tool deposition conditions of the Veeco Nexus ion beam deposition tool. The same tool was used for performing the actual deposition of the multilayer stack over the characterized native defects, thus ensuring a fair comparison between the actual multilayer growth over native defects, and modeled multilayer growth over regular-shaped defects. Further, the printability of the characterized native defects was studied with the SEMATECH-Berkeley Actinic Inspection Tool (AIT), an EUV mask-imaging microscope at Lawrence Berkeley National Laboratory (LBNL). Printability of the modeled regular-shaped defects, which were propagated up the multilayer stack using level-set growth model was studied using defect printability simulations implementing the waveguide algorithm. Good comparison was observed between AIT and the simulation results, thus demonstrating that multilayer growth over a defect is primarily a function of a defect’s width and height, irrespective of its shape. This would allow us to predict printability of the arbitrarily-shaped native EUV mask defects in a systematic and robust manner.« less

  12. Spatial Release From Masking in Simulated Cochlear Implant Users With and Without Access to Low-Frequency Acoustic Hearing

    PubMed Central

    Dietz, Mathias; Hohmann, Volker; Jürgens, Tim

    2015-01-01

    For normal-hearing listeners, speech intelligibility improves if speech and noise are spatially separated. While this spatial release from masking has already been quantified in normal-hearing listeners in many studies, it is less clear how spatial release from masking changes in cochlear implant listeners with and without access to low-frequency acoustic hearing. Spatial release from masking depends on differences in access to speech cues due to hearing status and hearing device. To investigate the influence of these factors on speech intelligibility, the present study measured speech reception thresholds in spatially separated speech and noise for 10 different listener types. A vocoder was used to simulate cochlear implant processing and low-frequency filtering was used to simulate residual low-frequency hearing. These forms of processing were combined to simulate cochlear implant listening, listening based on low-frequency residual hearing, and combinations thereof. Simulated cochlear implant users with additional low-frequency acoustic hearing showed better speech intelligibility in noise than simulated cochlear implant users without acoustic hearing and had access to more spatial speech cues (e.g., higher binaural squelch). Cochlear implant listener types showed higher spatial release from masking with bilateral access to low-frequency acoustic hearing than without. A binaural speech intelligibility model with normal binaural processing showed overall good agreement with measured speech reception thresholds, spatial release from masking, and spatial speech cues. This indicates that differences in speech cues available to listener types are sufficient to explain the changes of spatial release from masking across these simulated listener types. PMID:26721918

  13. Mask roughness induced LER: a rule of thumb -- paper

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    McClinton, Brittany; Naulleau, Patrick

    2010-03-12

    Much work has already been done on how both the resist and line-edge roughness (LER) on the mask affect the final printed LER. What is poorly understood, however, is the extent to which system-level effects such as mask surface roughness, illumination conditions, and defocus couple to speckle at the image plane, and currently factor into LER limits. Here, we propose a 'rule-of-thumb' simplified solution that provides a fast and powerful method to obtain mask roughness induced LER. We present modeling data on an older generation mask with a roughness of 230 pm as well as the ultimate target roughness ofmore » 50 pm. Moreover, we consider feature sizes of 50 nm and 22 nm, and show that as a function of correlation length, the LER peaks at the condition that the correlation length is approximately equal to the resolution of the imaging optic.« less

  14. Neuroimaging somatosensory perception and masking.

    PubMed

    Meador, Kimford J; Revill, Kathleen Pirog; Epstein, Charles M; Sathian, K; Loring, David W; Rorden, Chris

    2017-01-08

    The specific cortical and subcortical regions involved in conscious perception and masking are uncertain. This study sought to identify brain areas involved in conscious perception of somatosensory stimuli during a masking task using functional magnetic resonance (fMRI) to contrast perceived vs. non-perceived targets. Electrical trains were delivered to the right index finger for targets and to the left index finger for masks. Target intensities were adjusted to compensate for threshold drift. Sham target trials were given in ~10% of the trials, and target stimuli without masks were delivered in one of the five runs (68 trials/run). When healthy dextral adult volunteers (n=15) perceived right hand targets, greater left- than right-cerebral activations were seen with similar patterns across the parietal cortex, thalamus, insula, claustrum, and midbrain. When targets were not perceived, left/right cerebral activations were similar overall. Directly comparing perceived vs. non-perceived stimuli with similar intensities in the masking task revealed predominate activations contralateral to masks. In contrast, activations were greater contralateral to perceived targets if no masks were given or if masks were given but target stimulus intensities were greater for perceived than non-perceived targets. The novel aspects of this study include: 1) imaging of cortical and subcortical activations in healthy humans related to somatosensory perception during a masking task, 2) activations in the human thalamus and midbrain related to perception of stimuli compared to matched non-perceived stimuli, and 3) similar left/right cerebral activation patterns across cortical, thalamic and midbrain structures suggesting interactions across all three levels during conscious perception in humans. Copyright © 2016 Elsevier Ltd. All rights reserved.

  15. Type of mask may impact on continuous positive airway pressure adherence in apneic patients.

    PubMed

    Borel, Jean Christian; Tamisier, Renaud; Dias-Domingos, Sonia; Sapene, Marc; Martin, Francis; Stach, Bruno; Grillet, Yves; Muir, Jean François; Levy, Patrick; Series, Frederic; Pepin, Jean-Louis

    2013-01-01

    In obstructive sleep apnea patients (OSA), continuous positive airway pressure (CPAP) adherence is crucial to improve symptoms and cardiometabolic outcomes. The choice of mask may influence CPAP adherence but this issue has never been addressed properly. To evaluate the impact of nasal pillows, nasal and oronasal masks on CPAP adherence in a cohort of OSA. Newly CPAP treated OSA participating in "Observatoire Sommeil de la Fédération de Pneumologie", a French national prospective cohort, were included between March 2009 and December 2011. Anthropometric data, medical history, OSA severity, sleepiness, depressive status, treatment modalities (auto-CPAP versus fixed pressure, pressure level, interface type, use of humidifiers) and CPAP-related side effects were included in multivariate analysis to determine independent variables associated with CPAP adherence. 2311 OSA (age = 57(12) years, apnea+hypopnea index = 41(21)/h, 29% female) were included. Nasal masks, oronasal masks and nasal pillows were used by 62.4, 26.2 and 11.4% of the patients, respectively. In univariate analysis, oronasal masks and nasal pillows were associated with higher risk of CPAP non-adherence. CPAP non-adherence was also associated with younger age, female gender, mild OSA, gastroesophageal reflux, depression status, low effective pressure and CPAP-related side effects. In multivariate analysis, CPAP non-adherence was associated with the use of oronasal masks (OR = 2.0; 95%CI = 1.6; 2.5), depression, low effective pressure, and side effects. As oronasal masks negatively impact on CPAP adherence, a nasal mask should be preferred as the first option. Patients on oronasal masks should be carefully followed.

  16. Is the masked priming same-different task a pure measure of prelexical processing?

    PubMed

    Kelly, Andrew N; van Heuven, Walter J B; Pitchford, Nicola J; Ledgeway, Timothy

    2013-01-01

    To study prelexical processes involved in visual word recognition a task is needed that only operates at the level of abstract letter identities. The masked priming same-different task has been purported to do this, as the same pattern of priming is shown for words and nonwords. However, studies using this task have consistently found a processing advantage for words over nonwords, indicating a lexicality effect. We investigated the locus of this word advantage. Experiment 1 used conventional visually-presented reference stimuli to test previous accounts of the lexicality effect. Results rule out the use of different strategies, or strength of representations, for words and nonwords. No interaction was shown between prime type and word type, but a consistent word advantage was found. Experiment 2 used novel auditorally-presented reference stimuli to restrict nonword matching to the sublexical level. This abolished scrambled priming for nonwords, but not words. Overall this suggests the processing advantage for words over nonwords results from activation of whole-word, lexical representations. Furthermore, the number of shared open-bigrams between primes and targets could account for scrambled priming effects. These results have important implications for models of orthographic processing and studies that have used this task to investigate prelexical processes.

  17. Normalizing CO2 in chronic hyperventilation by means of a novel breathing mask: a pilot study.

    PubMed

    Johansen, Troels; Jack, Sandy; Dahl, Ronald

    2013-10-01

    Chronic idiopathic hyperventilation (CIH) is a form of dysfunctional breathing that has proven hard to treat effectively. To perform a preliminary test of the hypothesis that by periodically inducing normocapnia over several weeks, it would be possible to raise the normal resting level of CO2 and achieve a reduction of symptoms. Six CIH patients were treated 2 h a day for 4 weeks with a novel breathing mask. The mask was used to induce normocapnia in these chronically hypocapnic patients. Capillary blood gases and acid/base parameters [capillary CO2 tension (PcapCO2 ), pH, and standard base excess (SBE)] were measured at baseline and once each week at least 3 h after mask use, as well as spirometric values, breath-holding tolerance and hyperventilation symptoms as per the Nijmegen Questionnaire (NQ). The mask treatment resulted in a significant increase of resting PcapCO2 (+0.45 kPa, P = 0.028), a moderate increase in SBE (+1.4 mEq/L, P = 0.035) and a small reduction in daily symptoms (-3.8 NQ units, P = 0.046). The effect was most pronounced in the first 2 weeks of treatment. By inducing normocapnia with the breathing mask 2 h a day for 4 weeks, the normal resting CO2 and acid/base levels in chronically hyperventilating patients were partially corrected, and symptoms were reduced. © 2013 John Wiley & Sons Ltd.

  18. [Influence of music different in volume and style on human recognition activity].

    PubMed

    Pavlygina, R A; Sakharov, D S; Davydov, V I; Avdonkin, A V

    2009-01-01

    The efficiency of recognition of masked visual images (Arabic numerals) under conditions of listening to classical (intensity 62 dB) or rock music (25 dB) increased. Coherence of potential in the frontal cortical region characteristic of the masked image recognition increased under conditions of listening to music. The changes in intercenter EEG relations were correlated with the formation of "the recognition dominant" at the behavioral level. Such behavioral and EEG changes were not observed during listening to louder music (85 dB) and listening to music of other styles, however, the coherence between potentials of the temporal and motor areas of the right hemisphere increased, and the latency of hand motor reactions decreased. The results suggest that the "recognition dominant" is formed under conditions of establishment of certain relations between the levels of excitation in the corresponding centers. These findings should be taken into consideration in case if it were necessary to increase the efficiency of the recognition.

  19. Astronomical Near-neighbor Detection with a Four-quadrant Phase Mask (FQPM) Coronagraph

    NASA Technical Reports Server (NTRS)

    Haguenauer, Pierre; Serabyn, Eugene; Mennesson, Bertrand; Wallace, James K.; Gappinger, Robert O.; Troy, Mitchell; Bloemhof, Eric E.; Moore, Jim; Koresko, Chris D.

    2006-01-01

    Direct detection of planets around nearby stars requires the development of high-contrast imaging techniques, because of their very different respective fluxes. We thus investigated the innovative coronagraphic approach based on the use of a four-quadrant phase mask (FQPM). Simulations showed that, combined with high-level wavefront correction on an unobscured off-axis section of a large telescope, this method allows high-contrast imaging very close to stars, with detection capability superior to that of a traditional coronagraph. A FQPM instrument was thus built to test the feasibility of near-neighbor observations with our new off-axis approach on a ground-based telescope. In June 2005, we deployed our instrument to the Palomar 200-inch telescope, using existing facilities as much as possible for rapid implementation. In these initial observations, using data processing techniques specific to FQPM coronagraphs, we reached extinction levels of the order of 200:1. Here we discuss our simulations and on-sky results obtained so far.

  20. Robust Surface Reconstruction via Laplace-Beltrami Eigen-Projection and Boundary Deformation

    PubMed Central

    Shi, Yonggang; Lai, Rongjie; Morra, Jonathan H.; Dinov, Ivo; Thompson, Paul M.; Toga, Arthur W.

    2010-01-01

    In medical shape analysis, a critical problem is reconstructing a smooth surface of correct topology from a binary mask that typically has spurious features due to segmentation artifacts. The challenge is the robust removal of these outliers without affecting the accuracy of other parts of the boundary. In this paper, we propose a novel approach for this problem based on the Laplace-Beltrami (LB) eigen-projection and properly designed boundary deformations. Using the metric distortion during the LB eigen-projection, our method automatically detects the location of outliers and feeds this information to a well-composed and topology-preserving deformation. By iterating between these two steps of outlier detection and boundary deformation, we can robustly filter out the outliers without moving the smooth part of the boundary. The final surface is the eigen-projection of the filtered mask boundary that has the correct topology, desired accuracy and smoothness. In our experiments, we illustrate the robustness of our method on different input masks of the same structure, and compare with the popular SPHARM tool and the topology preserving level set method to show that our method can reconstruct accurate surface representations without introducing artificial oscillations. We also successfully validate our method on a large data set of more than 900 hippocampal masks and demonstrate that the reconstructed surfaces retain volume information accurately. PMID:20624704

  1. Defect reduction for semiconductor memory applications using jet and flash imprint lithography

    NASA Astrophysics Data System (ADS)

    Ye, Zhengmao; Luo, Kang; Lu, Xiaoming; Fletcher, Brian; Liu, Weijun; Xu, Frank; LaBrake, Dwayne; Resnick, Douglas J.; Sreenivasan, S. V.

    2012-07-01

    Acceptance of imprint lithography for manufacturing will require demonstration that it can attain defect levels commensurate with the defect specifications of high-end memory devices. Defects occurring during imprinting can generally be broken into two categories; random defects and repeating defects. Examples of random defects include fluid phase imprint defects, such as bubbles, and solid phase imprint defects, such as line collapse. Examples of repeater defects include mask fabrication defects and particle induced defects. Previous studies indicated that soft particles cause nonrepeating defects. Hard particles, on the other hand, can cause either permanent resist plugging or mask damage. In a previous study, two specific defect types were examined; random nonfill defects occurring during the resist filling process and repeater defects caused by interactions with particles on the substrate. We attempted to identify the different types of imprint defect types using a mask with line/space patterns at dimensions as small as 26 nm. An Imprio 500 twenty-wafer per hour development tool was used to study the various defect types. The imprint defect density was reduced nearly four orders of magnitude, down to ˜4/cm2 in a period of two years following the availability of low defect imprint masks at 26-nm half-pitch. This reduction was achieved by identifying the root cause of various defects and then taking the appropriate corrective action.

  2. The Effect of Oral Dexmedetomidine Premedication on Preoperative Cooperation and Emergence Delirium in Children Undergoing Dental Procedures.

    PubMed

    Keles, Sultan; Kocaturk, Ozlem

    2017-01-01

    The aim of this study was to detect the effect of 1  μ g/kg of oral dexmedetomidine (DEX) as premedication among children undergoing dental procedures. The study involved 100 children between 2 and 6 years of age, ASA I, who underwent full-mouth dental rehabilitation. The DEX group ( n = 50) received 1  μ g/kg DEX in apple juice, and the control group ( n = 50) received only apple juice. The patients' scores on the Ramsay Sedation Scale (RSS), parental separation anxiety scale, mask acceptance scale, and pediatric anesthesia emergence delirium scale (PAEDS) and hemodynamic parameters were recorded. The data were analyzed using chi-square test, Fisher's exact test, Student's t -test, and analysis of variance in SPSS. RSS scores were significantly higher in the DEX group than group C at 15, 30, and 45 min ( p < 0.05). More children (68% easy separation, 74% satisfactory mask acceptance) in the DEX group showed satisfactory ease of parental separation and mask acceptance behavior ( p < 0.05). There was no significant difference in the PAEDS scores and mean hemodynamic parameters of both groups. Oral DEX administered at 1  μ g/kg provided satisfactory sedation levels, ease of parental separation, and mask acceptance in children but was not effective in preventing emergence delirium. The trial was registered (Protocol Registration Receipt NCT03174678) at clinicaltrials.gov.

  3. Improving 130nm node patterning using inverse lithography techniques for an analog process

    NASA Astrophysics Data System (ADS)

    Duan, Can; Jessen, Scott; Ziger, David; Watanabe, Mizuki; Prins, Steve; Ho, Chi-Chien; Shu, Jing

    2018-03-01

    Developing a new lithographic process routinely involves usage of lithographic toolsets and much engineering time to perform data analysis. Process transfers between fabs occur quite often. One of the key assumptions made is that lithographic settings are equivalent from one fab to another and that the transfer is fluid. In some cases, that is far from the truth. Differences in tools can change the proximity effect seen in low k1 imaging processes. If you use model based optical proximity correction (MBOPC), then a model built in one fab will not work under the same conditions at another fab. This results in many wafers being patterned to try and match a baseline response. Even if matching is achieved, there is no guarantee that optimal lithographic responses are met. In this paper, we discuss the approach used to transfer and develop new lithographic processes and define MBOPC builds for the new lithographic process in Fab B which was transferred from a similar lithographic process in Fab A. By using PROLITHTM simulations to match OPC models for each level, minimal downtime in wafer processing was observed. Source Mask Optimization (SMO) was also used to optimize lithographic processes using novel inverse lithography techniques (ILT) to simultaneously optimize mask bias, depth of focus (DOF), exposure latitude (EL) and mask error enhancement factor (MEEF) for critical designs for each level.

  4. Fabless company mask technology approach: fabless but not fab-careless

    NASA Astrophysics Data System (ADS)

    Hisamura, Toshiyuki; Wu, Xin

    2009-10-01

    There are two different foundry-fabless working models in the aspect of mask. Some foundries have in-house mask facility while others contract with merchant mask vendors. Significant progress has been made in both kinds of situations. Xilinx as one of the pioneers of fabless semiconductor companies has been continually working very closely with both merchant mask vendors and mask facilities of foundries in past many years, contributed well in both technology development and benefited from corporations. Our involvement in manufacturing is driven by the following three elements: The first element is to understand the new fabrication and mask technologies and then find a suitable design / layout style to better utilize these new technologies and avoid potential risks. Because Xilinx has always been involved in early stage of advanced technology nodes, this early understanding and adoption is especially important. The second element is time to market. Reduction in mask and wafer manufacturing cycle-time can ensure faster time to market. The third element is quality. Commitment to quality is our highest priority for our customers. We have enough visibility on any manufacturing issues affecting the device functionality. Good correlation has consistently been observed between FPGA speed uniformity and the poly mask Critical Dimension (CD) uniformity performance. To achieve FPGA speed uniformity requirement, the manufacturing process as well as the mask and wafer CD uniformity has to be monitored. Xilinx works closely with the wafer foundries and mask suppliers to improve productivity and the yield from initial development stage of mask making operations. As an example, defect density reduction is one of the biggest challenges for mask supplier in development stage to meet the yield target satisfying the mask cost and mask turn-around-time (TAT) requirement. Historically, masks were considered to be defect free but at these advanced process nodes, that assumption no longer holds true. There is a need to be flexible enough on unrepairable defect at early stage but also a need for efficient risk management system on mask defect waivers. Mask defects are often waived in low design criticality area in favor of scrapping the mask and delaying the mask and wafer schedule. Xilinx's involvement in mask manufacturing has contributed significantly to our success in past many nodes and will continue.

  5. Computerized Dead-Space Volume Measurement of Face Masks Applied to Simulated Faces.

    PubMed

    Amirav, Israel; Luder, Anthony S; Halamish, Asaf; Marzuk, Chatib; Daitzchman, Marcelo; Newhouse, Michael T

    2015-09-01

    The dead-space volume (VD) of face masks for metered-dose inhaler treatments is particularly important in infants and young children with asthma, who have relatively low tidal volumes. Data about VD have been traditionally obtained from water displacement measurements, in which masks are held against a flat surface. Because, in real life, masks are placed against the face, VD is likely to differ considerably between masks depending upon their contour and fit. The aim of this study was to develop an accurate and reliable way to measure VD electronically and to apply this technique by comparing the electronic VD of commonly available face masks. Average digital faces were obtained from 3-dimensional images of 270 infants and children. Commonly used face masks (small and medium) from various manufacturers (Monaghan Medical, Pari Respiratory Equipment, Philips Respironics, and InspiRx) were scanned and digitized by means of computed tomography. Each mask was electronically applied to its respective digital face, and the VD enclosed (mL) was computerized and precisely measured. VD varied between 22.6 mL (SootherMask, InspiRx) and 43.1 mL (Vortex, Pari) for small masks and between 41.7 mL (SootherMask) and 71.5 mL (AeroChamber, Monaghan Medical) for medium masks. These values were significantly lower and less variable than measurements obtained by water displacement. Computerized techniques provide an innovative and relatively simple way of accurately measuring the VD of face masks applied to digital faces. As determined by computerized measurement using average-size virtual faces, the InspiRx masks had a significantly smaller VD for both small and medium masks compared with the other masks. This is of considerable importance with respect to aerosol dose and delivery time, particularly in young children. (ClinicalTrials.gov registration NCT01274299.). Copyright © 2015 by Daedalus Enterprises.

  6. The relationship between masking and short-term consolidation during recall from visual working memory.

    PubMed

    Ricker, Timothy J; Sandry, Joshua

    2018-04-10

    The presentation of a similar but irrelevant stimulus immediately following presentation of a memory item is called masking. Masking is known to reduce performance on working memory tests. This is the type of memory used to hold information in mind for brief periods of time for use in ongoing cognition. Two approaches to understanding masking effects have been proposed in different literatures. Working memory researchers often assume that the reduction in working memory performance after masking is because masking interferes with a transient sensory representation that is needed to complete consolidation into a working memory state. Researchers focused on the attentional blink, a finding that attention cannot be directed to new stimuli during working memory consolidation, have an alternative theory. Attentional blink researchers assume that masking slows the short-term consolidation process, thereby extending the length of the attentional blink. In two experiments, we contrast these two approaches to explaining masking effects and investigate the validity of both hypotheses. Some aspects of both approaches are validated, but neither theoretical perspective alone sufficiently explains the entire pattern of results. © 2018 New York Academy of Sciences.

  7. Getting the cocktail party started: masking effects in speech perception

    PubMed Central

    Evans, S; McGettigan, C; Agnew, ZK; Rosen, S; Scott, SK

    2016-01-01

    Spoken conversations typically take place in noisy environments and different kinds of masking sounds place differing demands on cognitive resources. Previous studies, examining the modulation of neural activity associated with the properties of competing sounds, have shown that additional speech streams engage the superior temporal gyrus. However, the absence of a condition in which target speech was heard without additional masking made it difficult to identify brain networks specific to masking and to ascertain the extent to which competing speech was processed equivalently to target speech. In this study, we scanned young healthy adults with continuous functional Magnetic Resonance Imaging (fMRI), whilst they listened to stories masked by sounds that differed in their similarity to speech. We show that auditory attention and control networks are activated during attentive listening to masked speech in the absence of an overt behavioural task. We demonstrate that competing speech is processed predominantly in the left hemisphere within the same pathway as target speech but is not treated equivalently within that stream, and that individuals who perform better in speech in noise tasks activate the left mid-posterior superior temporal gyrus more. Finally, we identify neural responses associated with the onset of sounds in the auditory environment, activity was found within right lateralised frontal regions consistent with a phasic alerting response. Taken together, these results provide a comprehensive account of the neural processes involved in listening in noise. PMID:26696297

  8. Masking Release for Igbo and English.

    PubMed

    Ebem, Deborah U; Desloge, Joseph G; Reed, Charlotte M; Braida, Louis D; Uguru, Joy O

    2013-09-01

    In this research, we explored the effect of noise interruption rate on speech intelligibility. Specifically, we used the Hearing In Noise Test (HINT) procedure with the original HINT stimuli (English) and Igbo stimuli to assess speech reception ability in interrupted noise. For a given noise level, the HINT test provides an estimate of the signal-to-noise ratio (SNR) required for 50%-correct speech intelligibility. The SNR for 50%-correct intelligibility changes depending upon the interruption rate of the noise. This phenomenon (called Masking Release) has been studied extensively in English but not for Igbo - which is an African tonal language spoken predominantly in South Eastern Nigeria. This experiment explored and compared the phenomenon of Masking Release for (i) native English speakers listening to English, (ii) native Igbo speakers listening to English, and (iii) native Igbo speakers listening to Igbo. Since Igbo is a tonal language and English is a non-tonal language, this allowed us to compare Masking Release patterns on native speakers of tonal and non-tonal languages. Our results for native English speakers listening to English HINT show that the SNR and the masking release are orderly and consistent with other English HINT data for English speakers. Our result for Igbo speakers listening to English HINT sentences show that there is greater variability in results across the different Igbo listeners than across the English listeners. This result likely reflects different levels of ability in the English language across the Igbo listeners. The masking release values in dB are less than for English listeners. Our results for Igbo speakers listening to Igbo show that in general, the SNRs for Igbo sentences are lower than for English/English and Igbo/English. This means that the Igbo listeners could understand 50% of the Igbo sentences at SNRs less than those required for English sentences by either native or non-native listeners. This result can be explained by the fact that the perception of Igbo utterances by Igbo subjects may have been aided by the prediction of tonal and vowel harmony features existent in the Igbo language. In agreement with other studies, our results also show that in a noisy environment listeners are able to perceive their native language better than a second language. The ability of native language speakers to perceive their language better than a second language in a noisy environment may be attributed to the fact that: Native speakers are more familiar with the sounds of their language than second language speakers.One of the features of language is that it is predictable hence even in noise a native speaker may be able to predict a succeeding word that is scarcely audible. These contextual effects are facilitated by familiarity.

  9. Reading a standing wave: figure-ground-alternation masking of primes in evaluative priming.

    PubMed

    Bermeitinger, Christina; Kuhlmann, Michael; Wentura, Dirk

    2012-09-01

    We propose a new masking technique for masking word stimuli. Drawing on the phenomena of metacontrast and paracontrast, we alternately presented two prime displays of the same word with the background color in one display matching the font color in the other display and vice versa. The sequence of twenty alterations (spanning approx. 267 ms) was sandwich-masked by structure masks. Using this masking technique, we conducted evaluative priming experiments with positive and negative target and prime words. Significant priming effects were found - for primes and targets drawn from the same as well as from different word sets. Priming effects were independent of prime discrimination performance in direct tests and they were still significant after the sample was restricted to those participants who showed random responding in the direct test. Copyright © 2012 Elsevier Inc. All rights reserved.

  10. Attentional Sensitization of Unconscious Cognition: Task Sets Modulate Subsequent Masked Semantic Priming

    ERIC Educational Resources Information Center

    Kiefer, Markus; Martens, Ulla

    2010-01-01

    According to classical theories, automatic processes are autonomous and independent of higher level cognitive influence. In contrast, the authors propose that automatic processing depends on attentional sensitization of task-congruent processing pathways. In 3 experiments, the authors tested this hypothesis with a modified masked semantic priming…

  11. Performance of a continuous flow passenger oxygen mask at an altitude of 40,000 feet.

    DOT National Transportation Integrated Search

    1996-02-01

    A redesigned continuous flow passenger oxygen mask was tested for its ability to deliver an adequate supply of oxygen at an altitude of 40,000 feet above sea level. Four male subjects participated in the study. Blood oxygen saturation (SaO2) baseline...

  12. Framework for Mapping of Receiver Interference Tolerance Masks to Tolerable Effective Isotropic Radiated Power Levels : GPS ABC Workshop V RTCA Washington, DC October 14, 2016.

    DOT National Transportation Integrated Search

    2016-10-14

    Outline : : Interference Tolerance Mask (ITM) to Effective Isotropic Radiated Power (IRP) for the particular case of a single transmitter : : ITM() to IRP() for the general case of multiple transmitters : : Input parameters needed to solv...

  13. The effects of fixed and removable face masks on maxillary deficiencies in growing patients.

    PubMed

    Jamilian, Abdolreza; Showkatbakhsh, Rahman; Taban, Tannaz

    2012-01-01

    To compare the effects of two different types of face masks in the treatment of Class III malocclusions with maxillary deficiency in growing patients. Forty-three patients (21 boys and 22 girls) with maxillary deficiencies were selected. Twenty-one patients (10 boys and 11 girls) with a mean age of 8.9 ± 1.4 years were treated with maxillary removable appliances and face masks. Twenty-two patients (10 boys and 12 girls) with a mean age of 9.3 ± 1.2 years were treated with maxillary fixed appliances and face masks. Lateral cephalograms obtained at the beginning and end of the study were analyzed. Paired t tests and Wilcoxon tests showed that SNA and ANB significantly increased in both groups. The Mann-Whitney test showed that there were no statistically significant differences between the two groups except for U1-SN, which increased by 6.2 ± 7.1 degrees in the removable face mask group and 11.1 ± 6.9 degrees in the fixed face mask group (P < .02). Both treatment modalities were successful in moving the maxilla forward. However, the maxillary incisors had more labial inclination in the fixed appliance group.

  14. The prevalence effect in lateral masking and its relevance for visual search.

    PubMed

    Geelen, B P; Wertheim, A H

    2015-04-01

    In stimulus displays with or without a single target amid 1,644 identical distractors, target prevalence was varied between 20, 50 and 80 %. Maximum gaze deviation was measured to determine the strength of lateral masking in these arrays. The results show that lateral masking was strongest in the 20 % prevalence condition, which differed significantly from both the 50 and 80 % prevalence conditions. No difference was observed between the latter two. This pattern of results corresponds to that found in the literature on the prevalence effect in visual search (stronger lateral masking corresponding to longer search times). The data add to similar findings reported earlier (Wertheim et al. in Exp Brain Res, 170:387-402, 2006), according to which the effects of many well-known factors in visual search correspond to those on lateral masking. These were the effects of set size, disjunctions versus conjunctions, display area, distractor density, the asymmetry effect (Q vs. O's) and viewing distance. The present data, taken together with those earlier findings, may lend credit to a causal hypothesis that lateral masking could be a more important mechanism in visual search than usually assumed.

  15. Patterning of light-extraction nanostructures on sapphire substrates using nanoimprint and ICP etching with different masking materials.

    PubMed

    Chen, Hao; Zhang, Qi; Chou, Stephen Y

    2015-02-27

    Sapphire nanopatterning is the key solution to GaN light emitting diode (LED) light extraction. One challenge is to etch deep nanostructures with a vertical sidewall in sapphire. Here, we report a study of the effects of two masking materials (SiO2 and Cr) and different etching recipes (the reaction gas ratio, the reaction pressure and the inductive power) in a chlorine-based (BCl3 and Cl2) inductively coupled plasma (ICP) etching of deep nanopillars in sapphire, and the etching process optimization. The masking materials were patterned by nanoimprinting. We have achieved high aspect ratio sapphire nanopillar arrays with a much steeper sidewall than the previous etching methods. We discover that the SiO2 mask has much slower erosion rate than the Cr mask under the same etching condition, leading to the deep cylinder-shaped nanopillars (122 nm diameter, 200 nm pitch, 170 nm high, flat top, and a vertical sidewall of 80° angle), rather than the pyramid-shaped shallow pillars (200 nm based diameter, 52 nm height, and 42° sidewall) resulted by using Cr mask. The processes developed are scalable to large volume LED manufacturing.

  16. Coronagraph Focal-Plane Phase Masks Based on Photonic Crystal Technology: Recent Progress and Observational Strategy

    NASA Technical Reports Server (NTRS)

    Murakami, Naoshi; Nishikawa, Jun; Sakamoto, Moritsugu; Ise, Akitoshi; Oka, Kazuhiko; Baba, Naoshi; Murakami, Hiroshi; Tamura, Motohide; Traub, Wesley A.; Mawet, Dimitri; hide

    2012-01-01

    Photonic crystal, an artificial periodic nanostructure of refractive indices, is one of the attractive technologies for coronagraph focal-plane masks aiming at direct imaging and characterization of terrestrial extrasolar planets. We manufactured the eight-octant phase mask (8OPM) and the vector vortex mask (VVM) very precisely using the photonic crystal technology. Fully achromatic phase-mask coronagraphs can be realized by applying appropriate polarization filters to the masks. We carried out laboratory experiments of the polarization-filtered 8OPM coronagraph using the High-Contrast Imaging Testbed (HCIT), a state-of-the-art coronagraph simulator at the Jet Propulsion Laboratory (JPL). We report the experimental results of 10-8-level contrast across several wavelengths over 10% bandwidth around 800nm. In addition, we present future prospects and observational strategy for the photonic-crystal mask coronagraphs combined with differential imaging techniques to reach higher contrast. We proposed to apply a polarization-differential imaging (PDI) technique to the VVM coronagraph, in which we built a two-channel coronagraph using polarizing beam splitters to avoid a loss of intensity due to the polarization filters. We also proposed to apply an angular-differential imaging (ADI) technique to the 8OPM coronagraph. The 8OPM/ADI mode avoids an intensity loss due to a phase transition of the mask and provides a full field of view around central stars. We present results of preliminary laboratory demonstrations of the PDI and ADI observational modes with the phase-mask coronagraphs.

  17. Human phoneme recognition depending on speech-intrinsic variability.

    PubMed

    Meyer, Bernd T; Jürgens, Tim; Wesker, Thorsten; Brand, Thomas; Kollmeier, Birger

    2010-11-01

    The influence of different sources of speech-intrinsic variation (speaking rate, effort, style and dialect or accent) on human speech perception was investigated. In listening experiments with 16 listeners, confusions of consonant-vowel-consonant (CVC) and vowel-consonant-vowel (VCV) sounds in speech-weighted noise were analyzed. Experiments were based on the OLLO logatome speech database, which was designed for a man-machine comparison. It contains utterances spoken by 50 speakers from five dialect/accent regions and covers several intrinsic variations. By comparing results depending on intrinsic and extrinsic variations (i.e., different levels of masking noise), the degradation induced by variabilities can be expressed in terms of the SNR. The spectral level distance between the respective speech segment and the long-term spectrum of the masking noise was found to be a good predictor for recognition rates, while phoneme confusions were influenced by the distance to spectrally close phonemes. An analysis based on transmitted information of articulatory features showed that voicing and manner of articulation are comparatively robust cues in the presence of intrinsic variations, whereas the coding of place is more degraded. The database and detailed results have been made available for comparisons between human speech recognition (HSR) and automatic speech recognizers (ASR).

  18. Complex Pupil Masks for Aberrated Imaging of Closely Spaced Objects

    NASA Astrophysics Data System (ADS)

    Reddy, A. N. K.; Sagar, D. K.; Khonina, S. N.

    2017-12-01

    Current approach demonstrates the suppression of optical side-lobes and the contraction of the main lobe in the composite image of two object points of the optical system under the influence of defocusing effect when an asymmetric phase edges are imposed over the apodized circular aperture. The resolution of two point sources having different intensity ratio is discussed in terms of the modified Sparrow criterion, functions of the degree of coherence of the illumination, the intensity difference and the degree of asymmetric phase masking. Here we have introduced and explored the effects of focus aberration (defect-of-focus) on the two-point resolution of the optical systems. Results on the aberrated composite image of closely spaced objects with amplitude mask and asymmetric phase masks forms a significant contribution in astronomical and microscopic observations.

  19. Hierarchical rendering of trees from precomputed multi-layer z-buffers

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Max, N.

    1996-02-01

    Chen and Williams show how precomputed z-buffer images from different fixed viewing positions can be reprojected to produce an image for a new viewpoint. Here images are precomputed for twigs and branches at various levels in the hierarchical structure of a tree, and adaptively combined, depending on the position of the new viewpoint. The precomputed images contain multiple z levels to avoid missing pixels in the reconstruction, subpixel masks for anti-aliasing, and colors and normals for shading after reprojection.

  20. Face Masks for Noninvasive Ventilation: Fit, Excess Skin Hydration, and Pressure Ulcers.

    PubMed

    Visscher, Marty O; White, Cynthia C; Jones, Jennifer M; Cahill, Thomas; Jones, Donna C; Pan, Brian S

    2015-11-01

    Pressure ulcers (stages III and IV) are serious safety events (ie, never events). Healthcare institutions are no longer reimbursed for costs to care for affected patients. Medical devices are the leading cause of pediatric pressure ulcers. Face masks for noninvasive ventilation were associated with a high percentage of pressure ulcers at our institution. A prospective cohort study investigated factors contributing to pressure ulcer development in 50 subjects using face masks for noninvasive ventilation. Color imaging, 3-dimensional surface imaging, and skin hydration measurements were used to identify early skin compromise and evaluate 3 interventions to reduce trauma: (1) a silicone foam dressing, (2) a water/polyethylene oxide hydrogel dressing, and (3) a flexible cloth mask. A novel mask fit technique was used to examine the impact of fit on the potential for skin compromise. Fifty subjects age 10.4 ± 9.1 y participated with color images for 22, hydration for 34, and mask fit analysis for 16. Of these, 69% had diagnoses associated with craniofacial anomalies. Stage I pressure ulcers were the most common injury. Skin hydration difference was 317 ± 29 for sites with erythema versus 75 ± 28 for sites without erythema (P < .05) and smallest for the cloth mask (P < .05). Fit distance metrics differed for the nasal, oronasal, and face shield interfaces, with threshold distances being higher for the oronasal mask than the others (P < .05). Areas of high contact were associated with skin erythema and pressure ulcers. This fit method is currently being utilized to select best-fit masks from available options, to identify the potential areas of increased tissue pressure, and to prevent skin injuries and their complications. Improvement of mask fit is an important priority for improving respiratory outcomes. Strategies to maintain normal skin hydration are important for protecting tissue integrity. Copyright © 2015 by Daedalus Enterprises.

  1. Electrophysiological Correlates of Subliminal Perception of Facial Expressions in Individuals with Autistic Traits: A Backward Masking Study

    PubMed Central

    Vukusic, Svjetlana; Ciorciari, Joseph; Crewther, David P.

    2017-01-01

    People with Autism spectrum disorder (ASD) show difficulty in social communication, especially in the rapid assessment of emotion in faces. This study examined the processing of emotional faces in typically developing adults with high and low levels of autistic traits (measured using the Autism Spectrum Quotient—AQ). Event-related potentials (ERPs) were recorded during viewing of backward-masked neutral, fearful and happy faces presented under two conditions: subliminal (16 ms, below the level of visual conscious awareness) and supraliminal (166 ms, above the time required for visual conscious awareness). Individuals with low and high AQ differed in the processing of subliminal faces, with the low AQ group showing an enhanced N2 amplitude for subliminal happy faces. Some group differences were found in the condition effects, with the Low AQ showing shorter frontal P3b and N4 latencies for subliminal vs. supraliminal condition. Although results did not show any group differences on the face-specific N170 component, there were shorter N170 latencies for supraliminal vs. subliminal conditions across groups. The results observed on the N2, showing group differences in subliminal emotion processing, suggest that decreased sensitivity to the reward value of social stimuli is a common feature both of people with ASD as well as people with high autistic traits from the normal population. PMID:28588465

  2. Electrophysiological Correlates of Subliminal Perception of Facial Expressions in Individuals with Autistic Traits: A Backward Masking Study.

    PubMed

    Vukusic, Svjetlana; Ciorciari, Joseph; Crewther, David P

    2017-01-01

    People with Autism spectrum disorder (ASD) show difficulty in social communication, especially in the rapid assessment of emotion in faces. This study examined the processing of emotional faces in typically developing adults with high and low levels of autistic traits (measured using the Autism Spectrum Quotient-AQ). Event-related potentials (ERPs) were recorded during viewing of backward-masked neutral, fearful and happy faces presented under two conditions: subliminal (16 ms, below the level of visual conscious awareness) and supraliminal (166 ms, above the time required for visual conscious awareness). Individuals with low and high AQ differed in the processing of subliminal faces, with the low AQ group showing an enhanced N2 amplitude for subliminal happy faces. Some group differences were found in the condition effects, with the Low AQ showing shorter frontal P3b and N4 latencies for subliminal vs. supraliminal condition. Although results did not show any group differences on the face-specific N170 component, there were shorter N170 latencies for supraliminal vs. subliminal conditions across groups. The results observed on the N2, showing group differences in subliminal emotion processing, suggest that decreased sensitivity to the reward value of social stimuli is a common feature both of people with ASD as well as people with high autistic traits from the normal population.

  3. Coatings on reflective mask substrates

    DOEpatents

    Tong, William Man-Wai; Taylor, John S.; Hector, Scott D.; Mangat, Pawitter J. S.; Stivers, Alan R.; Kofron, Patrick G.; Thompson, Matthew A.

    2002-01-01

    A process for creating a mask substrate involving depositing: 1) a coating on one or both sides of a low thermal expansion material EUVL mask substrate to improve defect inspection, surface finishing, and defect levels; and 2) a high dielectric coating, on the backside to facilitate electrostatic chucking and to correct for any bowing caused by the stress imbalance imparted by either other deposited coatings or the multilayer coating of the mask substrate. An film, such as TaSi, may be deposited on the front side and/or back of the low thermal expansion material before the material coating to balance the stress. The low thermal expansion material with a silicon overlayer and a silicon and/or other conductive underlayer enables improved defect inspection and stress balancing.

  4. Flotation Immunoassay: Masking the Signal from Free Reporters in Sandwich Immunoassays

    PubMed Central

    Chen, Hui; Hagström, Anna E. V.; Kim, Jinsu; Garvey, Gavin; Paterson, Andrew; Ruiz-Ruiz, Federico; Raja, Balakrishnan; Strych, Ulrich; Rito-Palomares, Marco; Kourentzi, Katerina; Conrad, Jacinta C.; Atmar, Robert L.; Willson, Richard C.

    2016-01-01

    In this work, we demonstrate that signal-masking reagents together with appropriate capture antibody carriers can eliminate the washing steps in sandwich immunoassays. A flotation immunoassay (FI) platform was developed with horseradish peroxidase chemiluminescence as the reporter system, the dye Brilliant Blue FCF as the signal-masking reagent, and buoyant silica micro-bubbles as the capture antibody carriers. Only reporters captured on micro-bubbles float above the dye and become visible in an analyte-dependent manner. These FIs are capable of detecting proteins down to attomole levels and as few as 106 virus particles. This signal-masking strategy represents a novel approach to simple, sensitive and quantitative immunoassays in both laboratory and point-of-care settings. PMID:27075635

  5. A Comparison of Different Techniques for Interfacing Capnography With Adult and Pediatric Supplemental Oxygen Masks.

    PubMed

    Phillips, Justin S; Pangilinan, Lance P; Mangalindan, Earl R E; Booze, Joseph L; Kallet, Richard H

    2017-01-01

    Accurately measuring the partial pressure of end-tidal CO 2 (P ETCO 2 ) in non-intubated patients is problematic due to dilution of expired CO 2 at high O 2 flows and mask designs that may either cause CO 2 rebreathing or inadequately capture expired CO 2 . We evaluated the performance of 2 capnographic O 2 masks (Cap-ONE and OxyMask) against a clinically expedient method using a standard O 2 mask with a flow-directed nasal cannula used for capnography (CapnoLine) in a spontaneous breathing model of an adult and child under conditions of normal ventilation, hypoventilation, and hyperventilation. An ASL-5000 simulator was attached to a manikin face with a catheter port, through which various CO 2 /air mixtures were bled into the ASL-5000 to achieve a P ETCO 2 of 40, 65, and 30 mm Hg. Both P ETCO 2 and inspired P CO 2 were measured at O 2 flows of 5, 10, 15, and 20 L/min (adult model) and 2, 4, 6, 8, and 10 L/min (pediatric model). P ETCO 2 decreased to varying degrees as O 2 flow increased, depending upon the breathing pattern. Although all devices appeared to perform reasonably well under normal and hyperventilation conditions, the clinically expedient method was associated with substantially more CO 2 rebreathing. P ETCO 2 usually deteriorated more under simulated hypoventilation, regardless of the measurement method. Both of the specially designed O 2 capnography masks provided reasonably stable P ETCO 2 without significant CO 2 rebreathing at the commonly used O 2 flows. Because of their open design, P ETCO 2 measured at high O 2 flows may produce artificially lower readings that may not reflect arterial CO 2 levels compared with lower O 2 flows. Copyright © 2017 by Daedalus Enterprises.

  6. Masked and unmasked error-related potentials during continuous control and feedback

    NASA Astrophysics Data System (ADS)

    Lopes Dias, Catarina; Sburlea, Andreea I.; Müller-Putz, Gernot R.

    2018-06-01

    The detection of error-related potentials (ErrPs) in tasks with discrete feedback is well established in the brain–computer interface (BCI) field. However, the decoding of ErrPs in tasks with continuous feedback is still in its early stages. Objective. We developed a task in which subjects have continuous control of a cursor’s position by means of a joystick. The cursor’s position was shown to the participants in two different modalities of continuous feedback: normal and jittered. The jittered feedback was created to mimic the instability that could exist if participants controlled the trajectory directly with brain signals. Approach. This paper studies the electroencephalographic (EEG)—measurable signatures caused by a loss of control over the cursor’s trajectory, causing a target miss. Main results. In both feedback modalities, time-locked potentials revealed the typical frontal-central components of error-related potentials. Errors occurring during the jittered feedback (masked errors) were delayed in comparison to errors occurring during normal feedback (unmasked errors). Masked errors displayed lower peak amplitudes than unmasked errors. Time-locked classification analysis allowed a good distinction between correct and error classes (average Cohen-, average TPR  =  81.8% and average TNR  =  96.4%). Time-locked classification analysis between masked error and unmasked error classes revealed results at chance level (average Cohen-, average TPR  =  60.9% and average TNR  =  58.3%). Afterwards, we performed asynchronous detection of ErrPs, combining both masked and unmasked trials. The asynchronous detection of ErrPs in a simulated online scenario resulted in an average TNR of 84.0% and in an average TPR of 64.9%. Significance. The time-locked classification results suggest that the masked and unmasked errors were indistinguishable in terms of classification. The asynchronous classification results suggest that the feedback modality did not hinder the asynchronous detection of ErrPs.

  7. Take a byte out of MEEF: VAMPIRE: Vehicle for Advanced Mask Pattern Inspection Readiness Evaluations

    NASA Astrophysics Data System (ADS)

    Badger, Karen D.; Rankin, Jed; Turley, Christina; Seki, Kazunori; Dechene, Dan J.; Abdelghany, Hesham

    2016-09-01

    MEEF, or Mask Error Enhancement Factor, is simply defined as the ratio of the change in printed wafer feature width to the change in mask feature width scaled to wafer level. It is important in chip manufacturing that leads to the amplification of mask errors, creating challenges with both achieving dimensional control tolerances and ensuring defect free masks, as measured by on-wafer image quality. As lithographic imaging continues to be stressed, using lower and lower k1 factor resolution enhancement techniques, the high MEEF areas present on advanced optical masks creates an environment where the need for increased mask defect sensitivity in high-MEEF areas becomes more and more critical. There are multiple approaches to mask inspection that may or may not provide enough sensitivity to detect all wafer-printable defects; the challenge in the application of these techniques is simultaneously maintaining an acceptable level of mask inspectability. The higher the MEEF, the harder the challenge will be to achieve and appropriate level of sensitivity while maintaining inspectability…and to do so on the geometries that matter. The predominant photomask fabrication inspection approach in use today compares the features on the reticle directly with the design database using high-NA optics. This approach has the ability to detect small defects, however, when inspecting aggressive OPC, it can lead to the over-detection of inconsequential, or nuisance defects. To minimize these nuisance detections, changing the sensitivity of the inspection can improve the inspectability of a mask inspected in high-NA mode, however, it leads to the inability to detect subtle, yet wafer-printable defects in High-MEEF geometry, due to the fact that this `desense' must be applied globally. There are also `lithography-emulating' approaches to inspection that use various means to provide high defect sensitivity and the ability to tolerate inconsequential, non-printing defects by using scanner-like conditions to determine which defects are wafer printable. This inspection technique is commonly referred to as being `lithography plane' or `litho plane,' since it's assessing the mask quality based on how the mask appears to the imaging optics during use, as proposed to traditional `reticle plane' inspection which is comparing the mask only with its target design. Regardless of how the defects are detected, the real question is when should they be detected? For larger technology nodes, defects are considered `statistical risks'…i.e., first they have to occur, and then they have to fall in high-MEEF areas in order to be of concern, and be below the detection limits of traditional reticle-plane inspection. In short, the `perfect storm' has to happen in order to miss printable defects using well-optimized traditional inspection approaches. The introduction of lithographic inspection techniques has revealed this statistical game is a much higher risk than originally estimated, in that very subtle waferprintable CD errors typically fall into the desense band for traditional reticle plane inspection. Because printability is largely influenced by MEEF, designs with high-MEEF values are at greater risk of traditional inspection missing printable CD errors. The question is… how high is high… and at what MEEF is optical inspection at the reticle plane sufficient? This paper will provide evaluation results for both reticle-plane and litho-plane inspections as they pertain to varying degrees of MEEF. A newly designed high-MEEF programmed defect test mask, named VAMPIRE, will be introduced. This test mask is based on 7 nm node technology and contains intentionally varying degrees of MEEF as well as a variety of programmed defects in high-MEEF environments…all of which have been verified for defect lithographic significance on a Zeiss AIMS system.

  8. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Henry, Michael David; Young, Travis R.; Griffin, Ben

    Here, this work reports the utilization of a recently developed film, ScAlN, as a silicon etch mask offering significant improvements in high etch selectivity to silicon. Utilization of ScAlN as a fluorine chemistry based deep reactive ion etch mask demonstrated etch selectivity at 23 550:1, four times better than AlN, 11 times better than Al 2O 3, and 148 times better than silicon dioxide with significantly less resputtering at high bias voltage than either Al 2O 3 or AlN. Ellipsometry film thickness measurements show less than 0.3 nm/min mask erosion rates for ScAlN. Micromasking of resputtered Al for Al 2Omore » 3, AlN, and ScAlN etch masks is also reported here, utilizing cross-sectional scanning electron microscope and confocal microscope roughness measurements. With lower etch bias, the reduced etch rate can be optimized to achieve a trench bottom surface roughness that is comparable to SiO 2 etch masks. Etch mask selectivity enabled by ScAlN is likely to make significant improvements in microelectromechanical systems, wafer level packaging, and plasma dicing of silicon.« less

  9. Exoplanet Coronagraph Shaped Pupil Masks and Laboratory Scale Star Shade Masks: Design, Fabrication and Characterization

    NASA Technical Reports Server (NTRS)

    Balasubramanian, Kunjithapatha; White, Victor; Yee, Karl; Echternach, Pierre; Muller, Richard; Dickie, Matthew; Cady, Eric; Mejia Prada, Camilo; Ryan, Daniel; Poberezhskiy, Ilya; hide

    2015-01-01

    Star light suppression technologies to find and characterize faint exoplanets include internal coronagraph instruments as well as external star shade occulters. Currently, the NASA WFIRST-AFTA mission study includes an internal coronagraph instrument to find and characterize exoplanets. Various types of masks could be employed to suppress the host star light to about 10 -9 level contrast over a broad spectrum to enable the coronagraph mission objectives. Such masks for high contrast internal coronagraphic imaging require various fabrication technologies to meet a wide range of specifications, including precise shapes, micron scale island features, ultra-low reflectivity regions, uniformity, wave front quality, achromaticity, etc. We present the approaches employed at JPL to produce pupil plane and image plane coronagraph masks by combining electron beam, deep reactive ion etching, and black silicon technologies with illustrative examples of each, highlighting milestone accomplishments from the High Contrast Imaging Testbed (HCIT) at JPL and from the High Contrast Imaging Lab (HCIL) at Princeton University. We also present briefly the technologies applied to fabricate laboratory scale star shade masks.

  10. Exoplanet coronagraph shaped pupil masks and laboratory scale star shade masks: design, fabrication and characterization

    NASA Astrophysics Data System (ADS)

    Balasubramanian, Kunjithapatham; White, Victor; Yee, Karl; Echternach, Pierre; Muller, Richard; Dickie, Matthew; Cady, Eric; Mejia Prada, Camilo; Ryan, Daniel; Poberezhskiy, Ilya; Zhou, Hanying; Kern, Brian; Riggs, A. J.; Zimmerman, Neil T.; Sirbu, Dan; Shaklan, Stuart; Kasdin, Jeremy

    2015-09-01

    Star light suppression technologies to find and characterize faint exoplanets include internal coronagraph instruments as well as external star shade occulters. Currently, the NASA WFIRST-AFTA mission study includes an internal coronagraph instrument to find and characterize exoplanets. Various types of masks could be employed to suppress the host star light to about 10-9 level contrast over a broad spectrum to enable the coronagraph mission objectives. Such masks for high contrast internal coronagraphic imaging require various fabrication technologies to meet a wide range of specifications, including precise shapes, micron scale island features, ultra-low reflectivity regions, uniformity, wave front quality, achromaticity, etc. We present the approaches employed at JPL to produce pupil plane and image plane coronagraph masks by combining electron beam, deep reactive ion etching, and black silicon technologies with illustrative examples of each, highlighting milestone accomplishments from the High Contrast Imaging Testbed (HCIT) at JPL and from the High Contrast Imaging Lab (HCIL) at Princeton University. We also present briefly the technologies applied to fabricate laboratory scale star shade masks.

  11. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Kalavagunta, C; Lin, M; Snider, J

    Purpose: To quantify the factors leading to thermoplastic mask bolus-associated-increased skin dose in head and neck IMRT/VMAT using EBT2 film. Methods: EBT2 film placed beneath a dual layer 3-point ORFIT head, neck and shoulder mask was used to test the effect of mask thickness, beam modulation, air gap, and beam obliquity on bolus effect. Mask thickness was varied based on the distribution of 1.6mm Orfilight layer on top of 2 mm Efficast layer. Beam modulation was varied by irradiating the film with an open field (no beam modulation) and a step and shoot field (beam modulation). Air gap between maskmore » and film was varied from 0 to 5mm. Beam obliquity was varied by irradiating the film at gantry angles of 0°, 35°, and 70°.Finally, film strips placed on a Rando phantom under an Orfit mask, in regions of expected high dose, were irradiated using 5 IMRT and 5 VMAT plans with various modulation levels (modulation factor 2 to 5) and the results were compared with those obtained placing OSLDs at the same locations. Results: An 18–34% increase in mask bolus effect was observed for three factors where the effect of beam obliquity ≥ beam modulation > mask thickness. No increase in mask bolus effect was observed for change in air gap. A 6–13% increase in dose due to mask bolus effect was observed on film strips. Conclusion: This work underlines the role of beam obliquity and beam modulation combined with thermoplastic mask thickness in increasing mask bolus-associated skin dose in head and neck IMRT/VMAT. One possible method of dose reduction, based on knowledge gained from this work, is inclusion of skin as an avoidance structure in treatment planning. Another approach is to design a mask with the least amount of thermoplastic material necessary for immobilization.« less

  12. Accelerator test of the coded aperture mask technique for gamma-ray astronomy

    NASA Technical Reports Server (NTRS)

    Jenkins, T. L.; Frye, G. M., Jr.; Owens, A.; Carter, J. N.; Ramsden, D.

    1982-01-01

    A prototype gamma-ray telescope employing the coded aperture mask technique has been constructed and its response to a point source of 20 MeV gamma-rays has been measured. The point spread function is approximately a Gaussian with a standard deviation of 12 arc minutes. This resolution is consistent with the cell size of the mask used and the spatial resolution of the detector. In the context of the present experiment, the error radius of the source position (90 percent confidence level) is 6.1 arc minutes.

  13. Practices around the use of masks and respirators among hospital health care workers in 3 diverse populations.

    PubMed

    Chughtai, Abrar Ahmad; MacIntyre, C Raina; Ashraf, Muhammad Orooj; Zheng, Yang; Yang, Peng; Wang, Quanyi; Dung, Tham Chi; Hien, Nguyen Tran; Seale, Holly

    2015-10-01

    A cross-sectional survey was conducted in 89 secondary- and tertiary-level hospitals in 3 countries, and samples of masks and respirators were also collected and examined. Results showed varied practices around the use of masks and respirators, which are probably influenced by the available resources and local recommendations. Nonstandardized practices are common in low-resource settings, which may be placing health care workers at risk. Copyright © 2015 Association for Professionals in Infection Control and Epidemiology, Inc. Published by Elsevier Inc. All rights reserved.

  14. Whether Visual Information Loss of Expression by Community Pharmacist Masks to Effect a Change in Feeling of Trust among Help-seeker?

    PubMed

    Kishimoto, Keiko; Hasaka, Akiko; Yamaura, Katsunori; Fukushima, Noriko

    2016-01-01

    Pharmacy is required to shift toward human service such as hearing the complaints of health. But the study about help-seeking behavior to pharmacist is not really investigated. We hypothesized that a decrease in expression visibility, due to pharmacists' typical masks, may negatively impact help-seeker' trust in pharmacist. The sample included 100 drugstore customers aged ≥18 years. Participants were stratified by gender and randomly assigned to two groups: evaluation of clear-masked and normal-masked pharmacists. After viewing a video with either male or female pharmacists wearing either clear or normal masks, participants completed a questionnaire. The primary outcome was trust in pharmacist measured by the Trust Scale and the secondary outcome was impression of the pharmacist measured by nineteen pairs of adjectives. There were no differences by gender on trust scores. Results revealed that both male and female pharmacists who wore clear masks were rated as more trustworthy than normal-masked pharmacists (p<0.001, d=0.903, and p=0.001, d=0.716, respectively). Sixteen of nineteen adjectives reported for pharmacists wearing normal masks indicated greater negative intention than those with clear masks (d=0.431-1.469). In most cases, among pharmacists wearing clear masks, results showed positive correlations between trust and each impression adjective (r=0.279-0.710). Our findings indicate that pharmacists wearing normal masks, which partially hide facial expressions, may decrease customer's trust in pharmacist. Further, normal masks were associated with negative impression. To avoid the inhibition of help-seek behavior, we recommend that pharmacists wear a clear mask and increase non-verbal communication.

  15. Cost-effective masks for deep x-ray lithography

    NASA Astrophysics Data System (ADS)

    Scheunemann, Heinz-Ulrich; Loechel, Bernd; Jian, Linke; Schondelmaier, Daniel; Desta, Yohannes M.; Goettert, Jost

    2003-04-01

    The production of X-ray masks is one of the key techniques for X-ray lithography and the LIGA process. Different ways for the fabrication of X-ray masks has been established. Very sophisticated, difficult and expensive procedures are required to produce high precision and high quality X-ray masks. In order to minimize the cost of an X-ray mask, the mask blank must be inexpensive and readily available. The steps involved in the fabrication process must also be minimal. In the past, thin membranes made of titanium, silicon carbide, silicon nitride (2-5μm) or thick beryllium substrates (500μm) have been used as mask blanks. Thin titanium and silicon compounds have very high transparency for X-rays; therefore, these materials are predestined for use as mask membrane material. However, the handling and fabrication of thin membranes is very difficult, thus expensive. Beryllium is highly transparent to X-rays, but the processing and use of beryllium is risky due to potential toxicity. During the past few years graphite based X-ray masks have been in use at various research centers, but the sidewall quality of the generated resist patterns is in the range of 200-300 nm Ra. We used polished graphite to improve the sidewall roughness, but polished graphite causes other problems in the fabrication of X-ray masks. This paper describes the advantages associated with the use of polished graphite as mask blank as well as the fabrication process for this low cost X-ray mask. Alternative membrane materials will also be discussed.

  16. Method for validating cloud mask obtained from satellite measurements using ground-based sky camera.

    PubMed

    Letu, Husi; Nagao, Takashi M; Nakajima, Takashi Y; Matsumae, Yoshiaki

    2014-11-01

    Error propagation in Earth's atmospheric, oceanic, and land surface parameters of the satellite products caused by misclassification of the cloud mask is a critical issue for improving the accuracy of satellite products. Thus, characterizing the accuracy of the cloud mask is important for investigating the influence of the cloud mask on satellite products. In this study, we proposed a method for validating multiwavelength satellite data derived cloud masks using ground-based sky camera (GSC) data. First, a cloud cover algorithm for GSC data has been developed using sky index and bright index. Then, Moderate Resolution Imaging Spectroradiometer (MODIS) satellite data derived cloud masks by two cloud-screening algorithms (i.e., MOD35 and CLAUDIA) were validated using the GSC cloud mask. The results indicate that MOD35 is likely to classify ambiguous pixels as "cloudy," whereas CLAUDIA is likely to classify them as "clear." Furthermore, the influence of error propagations caused by misclassification of the MOD35 and CLAUDIA cloud masks on MODIS derived reflectance, brightness temperature, and normalized difference vegetation index (NDVI) in clear and cloudy pixels was investigated using sky camera data. It shows that the influence of the error propagation by the MOD35 cloud mask on the MODIS derived monthly mean reflectance, brightness temperature, and NDVI for clear pixels is significantly smaller than for the CLAUDIA cloud mask; the influence of the error propagation by the CLAUDIA cloud mask on MODIS derived monthly mean cloud products for cloudy pixels is significantly smaller than that by the MOD35 cloud mask.

  17. Simulation based mask defect repair verification and disposition

    NASA Astrophysics Data System (ADS)

    Guo, Eric; Zhao, Shirley; Zhang, Skin; Qian, Sandy; Cheng, Guojie; Vikram, Abhishek; Li, Ling; Chen, Ye; Hsiang, Chingyun; Zhang, Gary; Su, Bo

    2009-10-01

    As the industry moves towards sub-65nm technology nodes, the mask inspection, with increased sensitivity and shrinking critical defect size, catches more and more nuisance and false defects. Increased defect counts pose great challenges in the post inspection defect classification and disposition: which defect is real defect, and among the real defects, which defect should be repaired and how to verify the post-repair defects. In this paper, we address the challenges in mask defect verification and disposition, in particular, in post repair defect verification by an efficient methodology, using SEM mask defect images, and optical inspection mask defects images (only for verification of phase and transmission related defects). We will demonstrate the flow using programmed mask defects in sub-65nm technology node design. In total 20 types of defects were designed including defects found in typical real circuit environments with 30 different sizes designed for each type. The SEM image was taken for each programmed defect after the test mask was made. Selected defects were repaired and SEM images from the test mask were taken again. Wafers were printed with the test mask before and after repair as defect printability references. A software tool SMDD-Simulation based Mask Defect Disposition-has been used in this study. The software is used to extract edges from the mask SEM images and convert them into polygons to save in GDSII format. Then, the converted polygons from the SEM images were filled with the correct tone to form mask patterns and were merged back into the original GDSII design file. This merge is for the purpose of contour simulation-since normally the SEM images cover only small area (~1 μm) and accurate simulation requires including larger area of optical proximity effect. With lithography process model, the resist contour of area of interest (AOI-the area surrounding a mask defect) can be simulated. If such complicated model is not available, a simple optical model can be used to get simulated aerial image intensity in the AOI. With built-in contour analysis functions, the SMDD software can easily compare the contour (or intensity) differences between defect pattern and normal pattern. With user provided judging criteria, this software can be easily disposition the defect based on contour comparison. In addition, process sensitivity properties, like MEEF and NILS, can be readily obtained in the AOI with a lithography model, which will make mask defect disposition criteria more intelligent.

  18. Effects of noise levels and call types on the source levels of killer whale calls.

    PubMed

    Holt, Marla M; Noren, Dawn P; Emmons, Candice K

    2011-11-01

    Accurate parameter estimates relevant to the vocal behavior of marine mammals are needed to assess potential effects of anthropogenic sound exposure including how masking noise reduces the active space of sounds used for communication. Information about how these animals modify their vocal behavior in response to noise exposure is also needed for such assessment. Prior studies have reported variations in the source levels of killer whale sounds, and a more recent study reported that killer whales compensate for vessel masking noise by increasing their call amplitude. The objectives of the current study were to investigate the source levels of a variety of call types in southern resident killer whales while also considering background noise level as a likely factor related to call source level variability. The source levels of 763 discrete calls along with corresponding background noise were measured over three summer field seasons in the waters surrounding the San Juan Islands, WA. Both noise level and call type were significant factors on call source levels (1-40 kHz band, range of 135.0-175.7 dB(rms) re 1 [micro sign]Pa at 1 m). These factors should be considered in models that predict how anthropogenic masking noise reduces vocal communication space in marine mammals.

  19. Aerial image based die-to-model inspections of advanced technology masks

    NASA Astrophysics Data System (ADS)

    Kim, Jun; Lei, Wei-Guo; McCall, Joan; Zaatri, Suheil; Penn, Michael; Nagpal, Rajesh; Faivishevsky, Lev; Ben-Yishai, Michael; Danino, Udy; Tam, Aviram; Dassa, Oded; Balasubramanian, Vivek; Shah, Tejas H.; Wagner, Mark; Mangan, Shmoolik

    2009-10-01

    Die-to-Model (D2M) inspection is an innovative approach to running inspection based on a mask design layout data. The D2M concept takes inspection from the traditional domain of mask pattern to the preferred domain of the wafer aerial image. To achieve this, D2M transforms the mask layout database into a resist plane aerial image, which in turn is compared to the aerial image of the mask, captured by the inspection optics. D2M detection algorithms work similarly to an Aerial D2D (die-to-die) inspection, but instead of comparing a die to another die it is compared to the aerial image model. D2M is used whenever D2D inspection is not practical (e.g., single die) or when a validation of mask conformity to design is needed, i.e., for printed pattern fidelity. D2M is of particular importance for inspection of logic single die masks, where no simplifying assumption of pattern periodicity may be done. The application can tailor the sensitivity to meet the needs at different locations, such as device area, scribe lines and periphery. In this paper we present first test results of the D2M mask inspection application at a mask shop. We describe the methodology of using D2M, and review the practical aspects of the D2M mask inspection.

  20. Temporal masking of multidimensional tactual stimuli

    NASA Astrophysics Data System (ADS)

    Tan, Hong Z.; Reed, Charlotte M.; Delhorne, Lorraine A.; Durlach, Nathaniel I.; Wan, Natasha

    2003-12-01

    Experiments were performed to examine the temporal masking properties of multidimensional tactual stimulation patterns delivered to the left index finger. The stimuli consisted of fixed-frequency sinusoidal motions in the kinesthetic (2 or 4 Hz), midfrequency (30 Hz), and cutaneous (300 Hz) frequency ranges. Seven stimuli composed of one, two, or three spectral components were constructed at each of two signal durations (125 or 250 ms). Subjects identified target signals under three different masking paradigms: forward masking, backward masking, and sandwiched masking (in which the target is presented between two maskers). Target identification was studied as a function of interstimulus interval (ISI) in the range 0 to 640 ms. For both signal durations, percent-correct scores increased with ISI for each of the three masking paradigms. Scores with forward and backward masking were similar and significantly higher than scores obtained with sandwiched masking. Analyses of error trials revealed that subjects showed a tendency to respond, more often than chance, with the masker, the composite of the masker and target, or the combination of the target and a component of the masker. The current results are compared to those obtained in previous studies of tactual recognition masking with brief cutaneous spatial patterns. The results are also discussed in terms of estimates of information transfer (IT) and IT rate, are compared to previous studies with multidimensional tactual signals, and are related to research on the development of tactual aids for the deaf.

  1. Migration from full-head mask to "open-face" mask for immobilization of patients with head and neck cancer.

    PubMed

    Li, Guang; Lovelock, D Michael; Mechalakos, James; Rao, Shyam; Della-Biancia, Cesar; Amols, Howard; Lee, Nancy

    2013-09-06

    To provide an alternative device for immobilization of the head while easing claustrophobia and improving comfort, an "open-face" thermoplastic mask was evaluated using video-based optical surface imaging (OSI) and kilovoltage (kV) X-ray radiography. A three-point thermoplastic head mask with a precut opening and reinforced strips was developed. After molding, it provided sufficient visible facial area as the region of interest for OSI. Using real-time OSI, the head motion of ten volunteers in the new mask was evaluated during mask locking and 15minutes lying on the treatment couch. Using a nose mark with reference to room lasers, forced head movement in open-face and full-head masks (with a nose hole) was compared. Five patients with claustrophobia were immobilized with open-face masks, set up using OSI and kV, and treated in 121 fractions, in which 61 fractions were monitored during treatment using real-time OSI. With the open-face mask, head motion was found to be 1.0 ± 0.6 mm and 0.4° ± 0.2° in volunteers during the experiment, and 0.8 ± 0.3 mm and 0.4° ± 0.2° in patients during treatment. These agree with patient motion calculated from pre-/post-treatment OSI and kV data using different anatomical landmarks. In volunteers, the head shift induced by mask-locking was 2.3 ± 1.7 mm and 1.8° ± 0.6°, and the range of forced movements in the open-face and full-head masks were found to be similar. Most (80%) of the volunteers preferred the open-face mask to the full-head mask, while claustrophobic patients could only tolerate the open-face mask. The open-face mask is characterized for its immobilization capability and can immobilize patients sufficiently (< 2 mm) during radiotherapy. It provides a clinical solution to the immobilization of patients with head and neck (HN) cancer undergoing radiotherapy, and is particularly beneficial for claustrophobic patients. This new open-face mask is readily adopted in radiotherapy clinic as a superior alternative to the standard full-head mask.

  2. Clinical efficacy and safety of a light mask for prevention of dark adaptation in treating and preventing progression of early diabetic macular oedema at 24 months (CLEOPATRA): a multicentre, phase 3, randomised controlled trial.

    PubMed

    Sivaprasad, Sobha; Vasconcelos, Joana C; Prevost, A Toby; Holmes, Helen; Hykin, Philip; George, Sheena; Murphy, Caroline; Kelly, Joanna; Arden, Geoffrey B

    2018-05-01

    We aimed to assess 24-month outcomes of wearing an organic light-emitting sleep mask as an intervention to treat and prevent progression of non-central diabetic macular oedema. CLEOPATRA was a phase 3, single-blind, parallel-group, randomised controlled trial undertaken at 15 ophthalmic centres in the UK. Adults with non-centre-involving diabetic macular oedema were randomly assigned (1:1) to wearing either a light mask during sleep (Noctura 400 Sleep Mask, PolyPhotonix Medical, Sedgefield, UK) or a sham (non-light) mask, for 24 months. Randomisation was by minimisation generated by a central web-based computer system. Outcome assessors were masked technicians and optometrists. The primary outcome was the change in maximum retinal thickness on optical coherence tomography (OCT) at 24 months, analysed using a linear mixed-effects model incorporating 4-monthly measurements and baseline adjustment. Analysis was done using the intention-to-treat principle in all randomised patients with OCT data. Safety was assessed in all patients. This trial is registered with Controlled-Trials.com, number ISRCTN85596558. Between April 10, 2014, and June 15, 2015, 308 patients were randomly assigned to wearing the light mask (n=155) or a sham mask (n=153). 277 patients (144 assigned the light mask and 133 the sham mask) contributed to the mixed-effects model over time, including 246 patients with OCT data at 24 months. The change in maximum retinal thickness at 24 months did not differ between treatment groups (mean change -9·2 μm [SE 2·5] for the light mask vs -12·9 μm [SE 2·9] for the sham mask; adjusted mean difference -0·65 μm, 95% CI -6·90 to 5·59; p=0·84). Median compliance with wearing the light mask at 24 months was 19·5% (IQR 1·9-51·6). No serious adverse events were related to either mask. The most frequent adverse events related to the assigned treatment were discomfort on the eyes (14 with the light mask vs seven with the sham mask), painful, sticky, or watery eyes (14 vs six), and sleep disturbance (seven vs one). The light mask as used in this study did not confer long-term therapeutic benefit on non-centre-involving diabetic macular oedema and the study does not support its use for this indication. The Efficacy and Mechanism Evaluation Programme, a Medical Research Council and National Institute for Health Research partnership. Copyright © 2018 The Author(s). Published by Elsevier Ltd. This is an Open Access article under the CC BY 4.0 license. Published by Elsevier Ltd.. All rights reserved.

  3. [Oxygenation: the impact of face mask coupling.].

    PubMed

    Gregori, Waldemar Montoya de; Mathias, Lígia Andrade da Silva Telles; Piccinini Filho, Luiz; Pena, Ernesto Leonardo de Carpio; Vicuna, Aníbal Heberto Mora; Vieira, Joaquim Edson

    2005-10-01

    Different oxygenation techniques aim at promoting denitrogenation before apnea during induction. The main reason why CIO2 = 100% cannot be reached is the lack of adequate face mask coupling, allowing the entry of room air. Although anesthesiologists know this principle, not all of them apply it correctly, facilitating the entry of air in fresh gases flow and consequently diluting CIO2. This prospective study was performed to comparatively evaluate, through the variation of oxygen expired concentration (CEO2), the efficacy of the oxygenation technique via face mask in the conditions routinely used by anesthesiologists, simulating situations of progressive leaks. Oxygen end-tidal concentrations of 15 volunteers, physical status ASA I, were studied with 8 deep breaths (vital capacity) in 60 s with fresh gas flow of 10 L.min-1. The face mask was: tightly fitted with 100% CIO2 (Tf100) or varying from 50% to 90%, (Tf50, Tf60, Tf70, Tf80, Tf90); gravity-coupled to face and 100% CIO2 (Grav) and moved 1 cm away from face with 100% CIO2 (Aw). CEO2 was recorded at 10 s intervals. P < 0.05 was considered statistically significant. CEO2 has increased for all groups (p < 0.001), but only Tf100 reached values close to ideal (82.20 - 87). Comparing mean CEO2 of Grav and Tf100 at the end of 60s, (82.20 and 65.87) there was a difference of approximately 20% between both techniques, since gravity-coupled mask only did not provide adequate oxygenation. There were no significant differences between groups Tf70 and Grav (65.87 and 62.67) in all studied moments, suggesting that the latter simulates a 70% CIO2 at 60 s. Mean Aw group CEO2 increased to 47.20 at 60s showing that this technique may be associated to unacceptable risk of hypoxemia. All situations of face mask coupling gradually increased CEO2, although with decreased oxygenation efficacy due to situations of face mask malposition. This study has shown the need for attention during oxygenation, using well coupled face mask and eliminating normal practices of moved away or gravity-coupled masks.

  4. Phase-shifting point diffraction interferometer mask designs

    DOEpatents

    Goldberg, Kenneth Alan

    2001-01-01

    In a phase-shifting point diffraction interferometer, different image-plane mask designs can improve the operation of the interferometer. By keeping the test beam window of the mask small compared to the separation distance between the beams, the problem of energy from the reference beam leaking through the test beam window is reduced. By rotating the grating and mask 45.degree., only a single one-dimensional translation stage is required for phase-shifting. By keeping two reference pinholes in the same orientation about the test beam window, only a single grating orientation, and thus a single one-dimensional translation stage, is required. The use of a two-dimensional grating allows for a multiplicity of pinholes to be used about the pattern of diffracted orders of the grating at the mask. Orientation marks on the mask can be used to orient the device and indicate the position of the reference pinholes.

  5. Validation of optical codes based on 3D nanostructures

    NASA Astrophysics Data System (ADS)

    Carnicer, Artur; Javidi, Bahram

    2017-05-01

    Image information encoding using random phase masks produce speckle-like noise distributions when the sample is propagated in the Fresnel domain. As a result, information cannot be accessed by simple visual inspection. Phase masks can be easily implemented in practice by attaching cello-tape to the plain-text message. Conventional 2D-phase masks can be generalized to 3D by combining glass and diffusers resulting in a more complex, physical unclonable function. In this communication, we model the behavior of a 3D phase mask using a simple approach: light is propagated trough glass using the angular spectrum of plane waves whereas the diffusor is described as a random phase mask and a blurring effect on the amplitude of the propagated wave. Using different designs for the 3D phase mask and multiple samples, we demonstrate that classification is possible using the k-nearest neighbors and random forests machine learning algorithms.

  6. High-emulation mask recognition with high-resolution hyperspectral video capture system

    NASA Astrophysics Data System (ADS)

    Feng, Jiao; Fang, Xiaojing; Li, Shoufeng; Wang, Yongjin

    2014-11-01

    We present a method for distinguishing human face from high-emulation mask, which is increasingly used by criminals for activities such as stealing card numbers and passwords on ATM. Traditional facial recognition technique is difficult to detect such camouflaged criminals. In this paper, we use the high-resolution hyperspectral video capture system to detect high-emulation mask. A RGB camera is used for traditional facial recognition. A prism and a gray scale camera are used to capture spectral information of the observed face. Experiments show that mask made of silica gel has different spectral reflectance compared with the human skin. As multispectral image offers additional spectral information about physical characteristics, high-emulation mask can be easily recognized.

  7. Type of Mask May Impact on Continuous Positive Airway Pressure Adherence in Apneic Patients

    PubMed Central

    Borel, Jean Christian; Tamisier, Renaud; Dias-Domingos, Sonia; Sapene, Marc; Martin, Francis; Stach, Bruno; Grillet, Yves; Muir, Jean François; Levy, Patrick; Series, Frederic; Pepin, Jean-Louis

    2013-01-01

    Rationale In obstructive sleep apnea patients (OSA), continuous positive airway pressure (CPAP) adherence is crucial to improve symptoms and cardiometabolic outcomes. The choice of mask may influence CPAP adherence but this issue has never been addressed properly. Objective To evaluate the impact of nasal pillows, nasal and oronasal masks on CPAP adherence in a cohort of OSA. Methods Newly CPAP treated OSA participating in “Observatoire Sommeil de la Fédération de Pneumologie”, a French national prospective cohort, were included between March 2009 and December 2011. Anthropometric data, medical history, OSA severity, sleepiness, depressive status, treatment modalities (auto-CPAP versus fixed pressure, pressure level, interface type, use of humidifiers) and CPAP-related side effects were included in multivariate analysis to determine independent variables associated with CPAP adherence. Results 2311 OSA (age = 57(12) years, apnea+hypopnea index = 41(21)/h, 29% female) were included. Nasal masks, oronasal masks and nasal pillows were used by 62.4, 26.2 and 11.4% of the patients, respectively. In univariate analysis, oronasal masks and nasal pillows were associated with higher risk of CPAP non-adherence. CPAP non-adherence was also associated with younger age, female gender, mild OSA, gastroesophageal reflux, depression status, low effective pressure and CPAP-related side effects. In multivariate analysis, CPAP non-adherence was associated with the use of oronasal masks (OR = 2.0; 95%CI = 1.6; 2.5), depression, low effective pressure, and side effects. Conclusion As oronasal masks negatively impact on CPAP adherence, a nasal mask should be preferred as the first option. Patients on oronasal masks should be carefully followed. PMID:23691209

  8. Disposable surgical face masks for preventing surgical wound infection in clean surgery.

    PubMed

    Lipp, Allyson; Edwards, Peggy

    2014-02-17

    Surgical face masks were originally developed to contain and filter droplets containing microorganisms expelled from the mouth and nasopharynx of healthcare workers during surgery, thereby providing protection for the patient. However, there are several ways in which surgical face masks could potentially contribute to contamination of the surgical wound, e.g. by incorrect wear or by leaking air from the side of the mask due to poor string tension. To determine whether disposable surgical face masks worn by the surgical team during clean surgery prevent postoperative surgical wound infection. We searched The Cochrane Wounds Group Specialised Register on 23 October 2013; The Cochrane Central Register of Controlled Trials (CENTRAL) (The Cochrane Library); Ovid MEDLINE; Ovid MEDLINE (In-Process & Other Non-Indexed Citations); Ovid EMBASE; and EBSCO CINAHL. Randomised controlled trials (RCTs) and quasi-randomised controlled trials comparing the use of disposable surgical masks with the use of no mask. Two review authors extracted data independently. Three trials were included, involving a total of 2113 participants. There was no statistically significant difference in infection rates between the masked and unmasked group in any of the trials. From the limited results it is unclear whether the wearing of surgical face masks by members of the surgical team has any impact on surgical wound infection rates for patients undergoing clean surgery.

  9. Bias-free lateral terahertz emitters—A simulation study

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Granzner, R., E-mail: ralf.granzner@tu-ilmenau.de; Schwierz, F.; Polyakov, V. M.

    2015-07-28

    The design and performance of bias-free InN-based THz emitters that exploit lateral photocurrents is studied by means of numerical simulations. We use a drift-diffusion model with adjusted carrier temperatures and mobilities. The applicability of this approach is demonstrated by a comparison with results from Monte-Carlo simulations. We consider a simple but robust lateral emitter concept using metal stripes with two different thicknesses with one of them being thin enough to be transparent for THz radiation. This arrangement can be easily multiplexed and the efficiency of this concept has already been demonstrated by experiment for GaAs substrates. In the present study,more » we consider InN, which is known to be an efficient photo-Dember emitter because of its superior transport properties. Our main focus is on the impact of the emitter design on the emission efficiency assuming different operation principles. Both the lateral photo-Dember (LPD) effect and built-in lateral field effects are considered. The appropriate choice of the metal stripe and window geometry as well as the impact of surface Fermi level pinning are investigated in detail, and design guidelines for efficient large area emitters using multiplexed structures are provided. We find that InN LPD emitters do not suffer from Fermi level pinning at the InN surface. The optimum emission efficiency is found for LPD emitter structures having 200 nm wide illumination windows and mask stripes. Emitter structures in which lateral electric fields are induced by the metal mask contacts can have a considerably higher efficiency than pure LPD emitters. In the best case, the THz emission of such structures is increased by one order of magnitude. Their optimum window size is 1 μm without the necessity of a partially transparent set of mask stripes.« less

  10. Exploration of BEOL line-space patterning options at 12 nm half-pitch and below

    NASA Astrophysics Data System (ADS)

    Decoster, S.; Lazzarino, F.; Petersen Barbosa Lima, L.; Li, W.; Versluijs, J.; Halder, S.; Mallik, A.; Murdoch, G.

    2018-03-01

    While the semiconductor industry is almost ready for high-volume manufacturing of the 7 nm technology node, research centers are defining and troubleshooting the patterning options for the 5 nm technology node (N5) and below. The target dimension for imec's N5 BEOL applications is 20-24 nm Metal Pitch (MP), which requires Self-Aligned multiple (Double/Quadruple/Octuple) Patterning approaches (SAxP) in combination with EUV or immersion lithography at 193 nm. There are numerous technical challenges to enable gratings at the hard mask level such as good uniformity across wafer, low line edge/width roughness (LER/LWR), large process window, and all of this at low cost. An even greater challenge is to transfer these gratings into the dielectric material at such critical dimensions, where increased line edge roughness, line wiggling and even pattern collapse can be expected for materials with small mechanical stability such as highly porous low-k dielectrics. In this work we first compare three different patterning options for 12 nm half-pitch gratings at the hard mask level: EUV-based SADP and 193i-based SAQP and SAOP. This comparison will be based on process window, line edge/width roughness and cost. Next, the transfer of 12 nm line/space gratings in the dielectric material is discussed and presented. The LER of the dielectric lines is investigated as a function of the dielectric material, the trench depth, and the stress in the sacrificial hard mask. Finally, we elaborate on the different options to enable scaling down from 24 nm MP to 16 nm MP, and demonstrate 8 nm line/space gratings with 193i-based SAOP.

  11. Fisheries impacts on China's coastal ecosystems: Unmasking a pervasive 'fishing down' effect.

    PubMed

    Liang, Cui; Pauly, Daniel

    2017-01-01

    Intensive fishing can strongly impact marine ecosystems; among other things, it usually causes the mean trophic level of the catches to decline, an indicator of the occurrence of the 'fishing down' (FD) phenomenon. Although FD occurs throughout the world oceans, it can easily be masked by diverse factors, which has misled authors as to its generality. In this contribution, which uses the East China Sea as an example, we explore the masking effect on FD of the taxonomic coarseness of catch data, of assuming that individual sizes remain constant after intensive fishing, and the geographic expansion of fisheries. The result showed that all of these masking factors occur in the East China Sea, where only a few species are reported separately and the bulk of the catch is pooled into non-informative 'mixed fishes'. Also, the small mesh sizes and intensive fishing have reduced the sizes of fish and their trophic levels, while the fisheries have expanded offshore. Overall, taking the masking factors into account, the fishing down effect, i.e., the decline of the mean trophic level of the catch between 1979 and 2014 is in the order of 0.15 TL per decade, i.e., one of the highest estimates of FD in the world. Some ecological implications are presented.

  12. Fisheries impacts on China's coastal ecosystems: Unmasking a pervasive ‘fishing down’ effect

    PubMed Central

    Pauly, Daniel

    2017-01-01

    Intensive fishing can strongly impact marine ecosystems; among other things, it usually causes the mean trophic level of the catches to decline, an indicator of the occurrence of the ‘fishing down’ (FD) phenomenon. Although FD occurs throughout the world oceans, it can easily be masked by diverse factors, which has misled authors as to its generality. In this contribution, which uses the East China Sea as an example, we explore the masking effect on FD of the taxonomic coarseness of catch data, of assuming that individual sizes remain constant after intensive fishing, and the geographic expansion of fisheries. The result showed that all of these masking factors occur in the East China Sea, where only a few species are reported separately and the bulk of the catch is pooled into non-informative ‘mixed fishes’. Also, the small mesh sizes and intensive fishing have reduced the sizes of fish and their trophic levels, while the fisheries have expanded offshore. Overall, taking the masking factors into account, the fishing down effect, i.e., the decline of the mean trophic level of the catch between 1979 and 2014 is in the order of 0.15 TL per decade, i.e., one of the highest estimates of FD in the world. Some ecological implications are presented. PMID:28267755

  13. Consumers' sensitivity to androstenone and the evaluation of different cooking methods to mask boar taint.

    PubMed

    Borrisser-Pairó, F; Panella-Riera, N; Gil, M; Kallas, Z; Linares, M B; Egea, M; Garrido, M D; Oliver, M A

    2017-01-01

    Boar taint is an unpleasant odour and flavour present in some entire male pigs that is due to the presence of androstenone and skatole. The aim of the study was to assess the sensitivity of 150 consumers to androstenone and to compare the acceptability and liking of meat from castrated and entire pigs, cooked with different cooking methods. Meat samples consisted of loins from castrated (CM) and entire male pigs (EM) with high levels of androstenone cooked by two cooking methods: sous-vide and fried/breaded with garlic and parsley. Consumers evaluated smell and flavour acceptability, and overall liking of CM and EM for each cooking method. The results of the study showed that dislike of androstenone odour increased significantly with sensitivity. The results of acceptability and overall liking were similar in CM and EM for both cooking methods. Therefore, the two cooking methods used in the study may be useful to mask boar taint. Copyright © 2016 Elsevier Ltd. All rights reserved.

  14. Masked priming and ERPs dissociate maturation of orthographic and semantic components of visual word recognition in children

    PubMed Central

    Eddy, Marianna D.; Grainger, Jonathan; Holcomb, Phillip J.; Mitra, Priya; Gabrieli, John D. E.

    2014-01-01

    This study examined the time-course of reading single words in children and adults using masked repetition priming and the recording of event-related potentials. The N250 and N400 repetition priming effects were used to characterize form- and meaning-level processing, respectively. Children had larger amplitude N250 effects than adults for both shorter and longer duration primes. Children did not differ from adults on the N400 effect. The difference on the N250 suggests that automaticity for form processing is still maturing in children relative to adults, while the lack of differentiation on the N400 effect suggests that meaning processing is relatively mature by late childhood. The overall similarity in the children’s repetition priming effects to adults’ effects is in line with theories of reading acquisition, according to which children rapidly transition to an orthographic strategy for fast access to semantic information from print. PMID:24313638

  15. Requirements and Design Reference Mission for the WFIRST-AFTA Coronagraph Instrument

    NASA Technical Reports Server (NTRS)

    Demers, Richard T.; Dekens, Frank; Calvet, Rob; Chang, Zensheu; Effinger, Robert; Ek, Eric; Hovland, Larry; Jones, Laura; Loc, Anthony; Nemati, Bijan; hide

    2015-01-01

    The WFIRST-AFTA coronagraph instrument take s advantage of AFTA s 2.4 -meter aperture to provide novel exoplanet imaging science at approximately the same instrument cost as an Explorer mission. The AFTA coronagraph also matures direct imaging technologies to high TRL for an Exo-Earth Imager in the next decade. The coronagraph Design Reference Mission (DRM) optical design is based on the highly successful High Contrast Imaging Testbed (HCIT), with modifications to accommodate the AFTA telescope design, service-ability, volume constraints, and the addition of an Integral Field Spectrograph (IFS). In order to optimally satisfy the three science objectives of planet imaging, planet spectral characterization and dust debris imaging, the coronagraph is designed to operate in two different modes : Hybrid Lyot Coronagraph or Shaped Pupil Coronagraph. Active mechanisms change pupil masks, focal plane masks, yot masks, and bandpass filters to shift between modes. A single optical beam train can thus operate alternatively as two different coronagraph architecture s. Structural Thermal Optical Performance (STOP) analysis predict s the instrument contrast with the Low Order Wave Front Control loop closed. The STOP analysis was also used to verify that the optical/structural/thermal design provides the extreme stability required for planet characterization in the presence of thermal disturbances expected in a typical observing scenario. This paper describes the instrument design and the flow down from science requirements to high level engineering requirements.

  16. Suppression of side lobes in a spectrum of fibre Bragg gratings due to the transverse displacement of phase mask with respect to the optical fibre

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Abdullina, S R; Nemov, I N; Babin, Sergei A

    2012-09-30

    The possibility of apodisation of fibre Bragg gratings (FBGs) recorded in the interference region of two Gaussian beams in the phase-mask scheme is considered. The FBG reflection spectra are numerically simulated for different values of recordingbeam parameters and the distance between the axes of interfering beams diffracted into different orders, which is varied by transverse displacement of the phase mask with respect to the optical fibre. Suppression of side lobes and smoothing out of the FBG spectrum with an increase in the transverse displacement of the phase mask is experimentally demonstrated. It is shown that this effect is caused bymore » the equalisation of the mean induced refractive index in the FBG region. (optical fibres, lasers and amplifiers. properties and applications)« less

  17. Surgical face masks worn by patients with multidrug-resistant tuberculosis: impact on infectivity of air on a hospital ward.

    PubMed

    Dharmadhikari, Ashwin S; Mphahlele, Matsie; Stoltz, Anton; Venter, Kobus; Mathebula, Rirhandzu; Masotla, Thabiso; Lubbe, Willem; Pagano, Marcello; First, Melvin; Jensen, Paul A; van der Walt, Martie; Nardell, Edward A

    2012-05-15

    Drug-resistant tuberculosis transmission in hospitals threatens staff and patient health. Surgical face masks used by patients with tuberculosis (TB) are believed to reduce transmission but have not been rigorously tested. We sought to quantify the efficacy of surgical face masks when worn by patients with multidrug-resistant TB (MDR-TB). Over 3 months, 17 patients with pulmonary MDR-TB occupied an MDR-TB ward in South Africa and wore face masks on alternate days. Ward air was exhausted to two identical chambers, each housing 90 pathogen-free guinea pigs that breathed ward air either when patients wore surgical face masks (intervention group) or when patients did not wear masks (control group). Efficacy was based on differences in guinea pig infections in each chamber. Sixty-nine of 90 control guinea pigs (76.6%; 95% confidence interval [CI], 68-85%) became infected, compared with 36 of 90 intervention guinea pigs (40%; 95% CI, 31-51%), representing a 56% (95% CI, 33-70.5%) decreased risk of TB transmission when patients used masks. Surgical face masks on patients with MDR-TB significantly reduced transmission and offer an adjunct measure for reducing TB transmission from infectious patients.

  18. Registration performance on EUV masks using high-resolution registration metrology

    NASA Astrophysics Data System (ADS)

    Steinert, Steffen; Solowan, Hans-Michael; Park, Jinback; Han, Hakseung; Beyer, Dirk; Scherübl, Thomas

    2016-10-01

    Next-generation lithography based on EUV continues to move forward to high-volume manufacturing. Given the technical challenges and the throughput concerns a hybrid approach with 193 nm immersion lithography is expected, at least in the initial state. Due to the increasing complexity at smaller nodes a multitude of different masks, both DUV (193 nm) and EUV (13.5 nm) reticles, will then be required in the lithography process-flow. The individual registration of each mask and the resulting overlay error are of crucial importance in order to ensure proper functionality of the chips. While registration and overlay metrology on DUV masks has been the standard for decades, this has yet to be demonstrated on EUV masks. Past generations of mask registration tools were not necessarily limited in their tool stability, but in their resolution capabilities. The scope of this work is an image placement investigation of high-end EUV masks together with a registration and resolution performance qualification. For this we employ a new generation registration metrology system embedded in a production environment for full-spec EUV masks. This paper presents excellent registration performance not only on standard overlay markers but also on more sophisticated e-beam calibration patterns.

  19. Face mask sampling for the detection of Mycobacterium tuberculosis in expelled aerosols.

    PubMed

    Williams, Caroline M L; Cheah, Eddy S G; Malkin, Joanne; Patel, Hemu; Otu, Jacob; Mlaga, Kodjovi; Sutherland, Jayne S; Antonio, Martin; Perera, Nelun; Woltmann, Gerrit; Haldar, Pranabashis; Garton, Natalie J; Barer, Michael R

    2014-01-01

    Although tuberculosis is transmitted by the airborne route, direct information on the natural output of bacilli into air by source cases is very limited. We sought to address this through sampling of expelled aerosols in face masks that were subsequently analyzed for mycobacterial contamination. In series 1, 17 smear microscopy positive patients wore standard surgical face masks once or twice for periods between 10 minutes and 5 hours; mycobacterial contamination was detected using a bacteriophage assay. In series 2, 19 patients with suspected tuberculosis were studied in Leicester UK and 10 patients with at least one positive smear were studied in The Gambia. These subjects wore one FFP30 mask modified to contain a gelatin filter for one hour; this was subsequently analyzed by the Xpert MTB/RIF system. In series 1, the bacteriophage assay detected live mycobacteria in 11/17 patients with wearing times between 10 and 120 minutes. Variation was seen in mask positivity and the level of contamination detected in multiple samples from the same patient. Two patients had non-tuberculous mycobacterial infections. In series 2, 13/20 patients with pulmonary tuberculosis produced positive masks and 0/9 patients with extrapulmonary or non-tuberculous diagnoses were mask positive. Overall, 65% of patients with confirmed pulmonary mycobacterial infection gave positive masks and this included 3/6 patients who received diagnostic bronchoalveolar lavages. Mask sampling provides a simple means of assessing mycobacterial output in non-sputum expectorant. The approach shows potential for application to the study of airborne transmission and to diagnosis.

  20. Face Mask Sampling for the Detection of Mycobacterium tuberculosis in Expelled Aerosols

    PubMed Central

    Malkin, Joanne; Patel, Hemu; Otu, Jacob; Mlaga, Kodjovi; Sutherland, Jayne S.; Antonio, Martin; Perera, Nelun; Woltmann, Gerrit; Haldar, Pranabashis; Garton, Natalie J.; Barer, Michael R.

    2014-01-01

    Background Although tuberculosis is transmitted by the airborne route, direct information on the natural output of bacilli into air by source cases is very limited. We sought to address this through sampling of expelled aerosols in face masks that were subsequently analyzed for mycobacterial contamination. Methods In series 1, 17 smear microscopy positive patients wore standard surgical face masks once or twice for periods between 10 minutes and 5 hours; mycobacterial contamination was detected using a bacteriophage assay. In series 2, 19 patients with suspected tuberculosis were studied in Leicester UK and 10 patients with at least one positive smear were studied in The Gambia. These subjects wore one FFP30 mask modified to contain a gelatin filter for one hour; this was subsequently analyzed by the Xpert MTB/RIF system. Results In series 1, the bacteriophage assay detected live mycobacteria in 11/17 patients with wearing times between 10 and 120 minutes. Variation was seen in mask positivity and the level of contamination detected in multiple samples from the same patient. Two patients had non-tuberculous mycobacterial infections. In series 2, 13/20 patients with pulmonary tuberculosis produced positive masks and 0/9 patients with extrapulmonary or non-tuberculous diagnoses were mask positive. Overall, 65% of patients with confirmed pulmonary mycobacterial infection gave positive masks and this included 3/6 patients who received diagnostic bronchoalveolar lavages. Conclusion Mask sampling provides a simple means of assessing mycobacterial output in non-sputum expectorant. The approach shows potential for application to the study of airborne transmission and to diagnosis. PMID:25122163

  1. Discrimination of face-like patterns in the giant panda (Ailuropoda melanoleuca).

    PubMed

    Dungl, Eveline; Schratter, Dagmar; Huber, Ludwig

    2008-11-01

    The black-and-white pattern of the giant panda's (Ailuropoda melanoleuca) fur is a conspicuous signal and may be used for mate-choice and intraspecific communication. Here the authors examined whether they have the perceptual and cognitive potential to make use of this information. Two juvenile subjects were trained on several discrimination problems in steps of increasing difficulty, whereby the stimuli required to discriminate ranged from geometric figures to pairs of differently orientated ellipses, pairs of ellipses with the same orientation but different angles, and finally discrimination of panda-like eye-mask patterns that differed only subtly in shape. Not only did both subjects achieve significant levels of discrimination in all these tasks, they also remembered discriminations for 6 months or even 1 year after the first presentation. Thus this study provided the first solid evidence of sufficient visual and cognitive potential in the giant panda to use the fur pattern or the facial masks for individual recognition, social communication, and perhaps, mate choice. (PsycINFO Database Record (c) 2008 APA, all rights reserved).

  2. EUVL back-insertion layout optimization

    NASA Astrophysics Data System (ADS)

    Civay, D.; Laffosse, E.; Chesneau, A.

    2018-03-01

    Extreme ultraviolet lithography (EUVL) is targeted for front-up insertion at advanced technology nodes but will be evaluated for back insertion at more mature nodes. EUVL can put two or more mask levels back on one mask, depending upon what level(s) in the process insertion occurs. In this paper, layout optimization methods are discussed that can be implemented when EUVL back insertion is implemented. The layout optimizations can be focused on improving yield, reliability or density, depending upon the design needs. The proposed methodology modifies the original two or more colored layers and generates an optimized single color EUVL layout design.

  3. Oxygen-Partial-Pressure Sensor for Aircraft Oxygen Mask

    NASA Technical Reports Server (NTRS)

    Kelly, Mark; Pettit, Donald

    2003-01-01

    A device that generates an alarm when the partial pressure of oxygen decreases to less than a preset level has been developed to help prevent hypoxia in a pilot or other crewmember of a military or other high-performance aircraft. Loss of oxygen partial pressure can be caused by poor fit of the mask or failure of a hose or other component of an oxygen distribution system. The deleterious physical and mental effects of hypoxia cause the loss of a military aircraft and crew every few years. The device is installed in the crewmember s oxygen mask and is powered via communication wiring already present in all such oxygen masks. The device (see figure) includes an electrochemical sensor, the output potential of which is proportional to the partial pressure of oxygen. The output of the sensor is amplified and fed to the input of a comparator circuit. A reference potential that corresponds to the amplified sensor output at the alarm oxygen-partial-pressure level is fed to the second input of the comparator. When the sensed partial pressure of oxygen falls below the minimum acceptable level, the output of the comparator goes from the low state (a few millivolts) to the high state (near the supply potential, which is typically 6.8 V for microphone power). The switching of the comparator output to the high state triggers a tactile alarm in the form of a vibration in the mask, generated by a small 1.3-Vdc pager motor spinning an eccentric mass at a rate between 8,000 and 10,000 rpm. The sensation of the mask vibrating against the crewmember s nose is very effective at alerting the crewmember, who may already be groggy from hypoxia and is immersed in an environment that is saturated with visual cues and sounds. Indeed, the sensation is one of rudeness, but such rudeness could be what is needed to stimulate the crewmember to take corrective action in a life-threatening situation.

  4. A prospective evaluation of open face masks for head and neck radiation therapy.

    PubMed

    Wiant, David; Squire, Sarah; Liu, Han; Maurer, Jacqueline; Lane Hayes, T; Sintay, Benjamin

    Head and neck (HN) radiation therapy patients are typically immobilized with closed thermoplastic masks that cover the face and may cause discomfort. In this work, we examine the use of open masks for HN radiation therapy. Fifty HN patients were prospectively randomized into 2 groups (25 closed masks, 25 open masks). The open-mask group was monitored with surface imaging to evaluate intrafraction motion. Both groups underwent daily volumetric imaging. All daily images were rigidly registered to their respective planning images to evaluate spinal canal and mandible position as a check for interfraction posture change. Posture changes were determined by the amount the spinal canal and mandible contours from the planning images had to be expanded to cover the structures on each daily image set. The vector length (VL) of the intrafraction linear translations, spine, and mandible positions for each open-mask patient were checked for correlation with fraction number using the Pearson r value. All patients were given a weekly survey ranking anxiety and claustrophobia from 0 to 10 (0 = no issue, 10 = extreme issue). The mean VL for all open-mask patients was 0.9 ± 0.5 mm (1 standard deviation). Only 1 patient showed significant correlation between VL and fraction number. The mean contour expansions to cover the spine and mandible were 1.5 ± 0.9 mm and 1.8 ± 1.3 mm for the closed-mask group, and 1.6 ± 0.8 mm and 1.8 ± 1.1 mm for the open-mask group. Both groups showed similar behavior relative to fraction number. The mean anxiety and claustrophobia scores were 1.63 and 1.44 for the closed-mask group, and 0.81 and 0.63 for the open-mask group. The groups were not significantly different. Open masks provide comparable immobilization and posture preservation to closed masks for HN radiation therapy. Copyright © 2016 American Society for Radiation Oncology. Published by Elsevier Inc. All rights reserved.

  5. [Effect of oxygen tubing connection site on percutaneous oxygen partial pressure and percutaneous carbon dioxide partial pressure in patients with chronic obstructive pulmonary disease during noninvasive positive pressure ventilation].

    PubMed

    Mi, S; Zhang, L M

    2017-04-12

    Objective: We evaluated the effects of administering oxygen through nasal catheters inside the mask or through the mask on percutaneous oxygen partial pressure (PcO(2))and percutaneous carbon dioxide partial pressure (PcCO(2)) during noninvasive positive pressure ventilation (NPPV) to find a better way of administering oxygen, which could increase PcO(2) by increasing the inspired oxygen concentration. Methods: Ten healthy volunteers and 9 patients with chronic obstructive pulmonary disease complicated by type Ⅱ respiratory failure were included in this study. Oxygen was administered through a nasal catheter inside the mask or through the mask (oxygen flow was 3 and 5 L/min) during NPPV. PcO(2) and PcCO(2) were measured to evaluate the effects of administering oxygen through a nasal catheter inside the mask or through the mask, indirectly reflecting the effects of administering oxygen through nasal catheter inside the mask or through the mask on inspired oxygen concentration. Results: Compared to administering oxygen through the mask during NPPV, elevated PcO(2) was measured in administering oxygen through the nasal catheter inside the mask, and the differences were statistically significant ( P <0.05). At the same time, there was no significant change in PcCO(2) ( P >0.05). Conclusion: Administering oxygen through a nasal catheter inside the mask during NPPV increased PcO(2) by increasing the inspired oxygen concentration but did not increase PcCO(2). This method of administering oxygen could conserve oxygen and be suitable for family NPPV. Our results also provided theoretical basis for the development of new masks.

  6. Fabrication and characterisation of embedded metal nanostructures by ion implantation with nanoporous anodic alumina masks

    NASA Astrophysics Data System (ADS)

    Guan, Wei; Peng, Nianhua; Jeynes, Christopher; Ghatak, Jay; Peng, Yong; Ross, Ian M.; Bhatta, Umananda M.; Inkson, Beverley J.; Möbus, Günter

    2013-07-01

    Lateral ordered Co, Pt and Co/Pt nanostructures were fabricated in SiO2 and Si3N4 substrates by high fluence metal ion implantation through periodic nanochannel membrane masks based on anodic aluminium oxides (AAO). The quality of nanopatterning transfer defined by various AAO masks in different substrates was examined by transmission electron microscopy (TEM) in both imaging and spectroscopy modes.

  7. Perceptual latency priming by masked and unmasked stimuli: evidence for an attentional interpretation.

    PubMed

    Scharlau, Ingrid; Neumann, Odmar

    2003-08-01

    Four experiments investigated the influence of a metacontrast-masked prime on temporal order judgments. The main results were (1) that a masked prime reduced the latency of the mask's conscious perception (perceptual latency priming), (2) that this effect was independent of whether the prime suffered strong or weak masking, (3) that it was unaffected by the degree of visual similarity between the prime and the mask, and that (4) there was no difference between congruent and incongruent primes. Finding (1) suggests that location cueing affects not only response times but also the latency of conscious perception. (2) The finding that priming was unaffected by the prime's detectability argues against a response bias interpretation of this effect. (3) Since visual similarity had no effect on the prime's efficiency, it is unlikely that sensory priming was involved. (4) The lack of a divergence between the effects of congruent and incongruent primes implies a functional difference between the judgments in the temporal order judgment task and speeded responses that have demonstrated differential effects of congruent and incongruent primes (e.g., Klotz & Neumann, 1999). These results can best be interpreted by assuming that the prime affects perceptual latency by initiating a shift of attention, as suggested by the Asynchronous Updating Model (AUM; Neumann 1978, 1982).

  8. Feedforward and feedback control in apraxia of speech: effects of noise masking on vowel production.

    PubMed

    Maas, Edwin; Mailend, Marja-Liisa; Guenther, Frank H

    2015-04-01

    This study was designed to test two hypotheses about apraxia of speech (AOS) derived from the Directions Into Velocities of Articulators (DIVA) model (Guenther et al., 2006): the feedforward system deficit hypothesis and the feedback system deficit hypothesis. The authors used noise masking to minimize auditory feedback during speech. Six speakers with AOS and aphasia, 4 with aphasia without AOS, and 2 groups of speakers without impairment (younger and older adults) participated. Acoustic measures of vowel contrast, variability, and duration were analyzed. Younger, but not older, speakers without impairment showed significantly reduced vowel contrast with noise masking. Relative to older controls, the AOS group showed longer vowel durations overall (regardless of masking condition) and a greater reduction in vowel contrast under masking conditions. There were no significant differences in variability. Three of the 6 speakers with AOS demonstrated the group pattern. Speakers with aphasia without AOS did not differ from controls in contrast, duration, or variability. The greater reduction in vowel contrast with masking noise for the AOS group is consistent with the feedforward system deficit hypothesis but not with the feedback system deficit hypothesis; however, effects were small and not present in all individual speakers with AOS. Theoretical implications and alternative interpretations of these findings are discussed.

  9. Feedforward and Feedback Control in Apraxia of Speech: Effects of Noise Masking on Vowel Production

    PubMed Central

    Mailend, Marja-Liisa; Guenther, Frank H.

    2015-01-01

    Purpose This study was designed to test two hypotheses about apraxia of speech (AOS) derived from the Directions Into Velocities of Articulators (DIVA) model (Guenther et al., 2006): the feedforward system deficit hypothesis and the feedback system deficit hypothesis. Method The authors used noise masking to minimize auditory feedback during speech. Six speakers with AOS and aphasia, 4 with aphasia without AOS, and 2 groups of speakers without impairment (younger and older adults) participated. Acoustic measures of vowel contrast, variability, and duration were analyzed. Results Younger, but not older, speakers without impairment showed significantly reduced vowel contrast with noise masking. Relative to older controls, the AOS group showed longer vowel durations overall (regardless of masking condition) and a greater reduction in vowel contrast under masking conditions. There were no significant differences in variability. Three of the 6 speakers with AOS demonstrated the group pattern. Speakers with aphasia without AOS did not differ from controls in contrast, duration, or variability. Conclusion The greater reduction in vowel contrast with masking noise for the AOS group is consistent with the feedforward system deficit hypothesis but not with the feedback system deficit hypothesis; however, effects were small and not present in all individual speakers with AOS. Theoretical implications and alternative interpretations of these findings are discussed. PMID:25565143

  10. Unconscious processing of facial affect in children and adolescents.

    PubMed

    Killgore, William D S; Yurgelun-Todd, Deborah A

    2007-01-01

    In a previous study, with adults, we demonstrated that the amygdala and anterior cingulate gyrus are differentially responsive to happy and sad faces presented subliminally. Because the ability to perceive subtle facial signals communicating sadness is an important aspect of prosocial development, and is critical for empathic behavior, we examined this phenomenon from a developmental perspective using a backward masking paradigm. While undergoing functional magnetic resonance imaging (fMRI), 10 healthy adolescent children were presented with a series of happy and sad facial expressions, each lasting 20 ms and masked immediately by a neutral face to prevent conscious awareness of the affective expression. Relative to fixation baseline, masked sad faces activated the right amygdala, whereas masked happy faces failed to activate any of the regions of interest. Direct comparison between masked happy and sad faces revealed valence specific differences in the anterior cingulate gyrus. When the data were compared statistically to our previous sample of adults, the adolescent group showed significantly greater activity in the right amygdala relative to the adults during the masked sad condition. Groups also differed in several non-hypothesized regions. Development of unconscious perception from adolescence into adulthood appears to be accompanied by reduced activity within limbic affect processing systems, and perhaps increased involvement of other cortical and cerebellar systems.

  11. WFIRST-AFTA coronagraph shaped pupil masks: design, fabrication, and characterization

    NASA Astrophysics Data System (ADS)

    Balasubramanian, Kunjithapatham; White, Victor; Yee, Karl; Echternach, Pierre; Muller, Richard; Dickie, Matthew; Cady, Eric; Prada, Camilo Mejia; Ryan, Daniel; Poberezhskiy, Ilya; Kern, Brian; Zhou, Hanying; Krist, John; Nemati, Bijan; Eldorado Riggs, A. J.; Zimmerman, Neil T.; Kasdin, N. Jeremy

    2016-01-01

    NASA WFIRST-AFTA mission study includes a coronagraph instrument to find and characterize exoplanets. Various types of masks could be employed to suppress the host starlight to about 10-9 level contrast over a broad spectrum to enable the coronagraph mission objectives. Such masks for high-contrast internal coronagraphic imaging require various fabrication technologies to meet a wide range of specifications, including precise shapes, micron scale island features, ultralow reflectivity regions, uniformity, wave front quality, and achromaticity. We present the approaches employed at JPL to produce pupil plane and image plane coronagraph masks by combining electron beam, deep reactive ion etching, and black silicon technologies with illustrative examples of each, highlighting milestone accomplishments from the High Contrast Imaging Testbed at JPL and from the High Contrast Imaging Lab at Princeton University.

  12. Speech-evoked Brainstem Auditory Responses and Auditory Processing Skills: A Correlation in Adults with Hearing Loss

    PubMed Central

    Sanguebuche, Taissane Rodrigues; Peixe, Bruna Pias; Bruno, Rúbia Soares; Biaggio, Eliara Pinto Vieira; Garcia, Michele Vargas

    2018-01-01

    Introduction  The auditory system consists of sensory structures and central connections. The evaluation of the auditory pathway at a central level can be performed through behavioral and electrophysiological tests, because they are complementary to each other and provide important information about comprehension. Objective  To correlate the findings of speech brainstem-evoked response audiometry with the behavioral tests Random Gap Detection Test and Masking Level Difference in adults with hearing loss. Methods  All patients were submitted to a basic audiological evaluation, to the aforementioned behavioral tests, and to an electrophysiological assessment, by means of click-evoked and speech-evoked brainstem response audiometry. Results  There were no statistically significant values among the electrophysiological test and the behavioral tests. However, there was a significant correlation between the V and A waves, as well as the D and F waves, of the speech-evoked brainstem response audiometry peaks. Such correlations are positive, indicating that the increase of a variable implies an increase in another and vice versa. Conclusion  It was possible to correlate the findings of the speech-evoked brainstem response audiometry with those of the behavioral tests Random Gap Detection and Masking Level Difference. However, there was no statistically significant correlation between them. This shows that the electrophysiological evaluation does not depend uniquely on the behavioral skills of temporal resolution and selective attention. PMID:29379574

  13. Suitability of E-tongue Sensors to Assess Taste-Masking of Pediatric Liquids by Different Beverages Considering Their Physico-chemical Properties.

    PubMed

    Immohr, Laura Isabell; Hedfeld, Claas; Lang, Artur; Pein-Hackelbusch, Miriam

    2017-02-01

    Manipulation of liquid oral drugs by mixing them into foodstuff is a common procedure for taste-masking of OTC pharmaceuticals when administered to children. However, the taste-masking capability of such application media is not systematically evaluated, and recommendations for suitable media are hardly published. In this study, a sensor array of commercially available and self-developed electronic tongue sensors was employed to assess the taste-masking efficiency of eight different beverages (tap water, apple juice, carrot juice, fennel tea, fruit tea, milk, cocoa, and Alete meal to drink) on the OTC pharmaceuticals Ambroxol-ratiopharm®, Cetirizin AL, and Laxoberal® by multivariate data analysis. The Euclidean distances between each pure application medium and its corresponding drug mixture were used as an indicator for the taste-masking efficiency and correlated to the physico-chemical properties of the beverages. Thus, the pH value, the viscosity, as well as the fat and sugar content of the beverages were included, whereas only the viscosity appeared to be insignificant in all cases. The sugar content as well as the fat content and pH value emerged to be a significant variable in taste-masking efficiency for some of the tested drug products. It was shown that the applied electronic tongue sensors were capable to demonstrate the impact of the physico-chemical properties of the application media on their taste-masking capacity regardless of their non-selectivity towards these characteristics.

  14. EUV mask manufacturing readiness in the merchant mask industry

    NASA Astrophysics Data System (ADS)

    Green, Michael; Choi, Yohan; Ham, Young; Kamberian, Henry; Progler, Chris; Tseng, Shih-En; Chiou, Tsann-Bim; Miyazaki, Junji; Lammers, Ad; Chen, Alek

    2017-10-01

    As nodes progress into the 7nm and below regime, extreme ultraviolet lithography (EUVL) becomes critical for all industry participants interested in remaining at the leading edge. One key cost driver for EUV in the supply chain is the reflective EUV mask. As of today, the relatively few end users of EUV consist primarily of integrated device manufactures (IDMs) and foundries that have internal (captive) mask manufacturing capability. At the same time, strong and early participation in EUV by the merchant mask industry should bring value to these chip makers, aiding the wide-scale adoption of EUV in the future. For this, merchants need access to high quality, representative test vehicles to develop and validate their own processes. This business circumstance provides the motivation for merchants to form Joint Development Partnerships (JDPs) with IDMs, foundries, Original Equipment Manufacturers (OEMs) and other members of the EUV supplier ecosystem that leverage complementary strengths. In this paper, we will show how, through a collaborative supplier JDP model between a merchant and OEM, a novel, test chip driven strategy is applied to guide and validate mask level process development. We demonstrate how an EUV test vehicle (TV) is generated for mask process characterization in advance of receiving chip maker-specific designs. We utilize the TV to carry out mask process "stress testing" to define process boundary conditions which can be used to create Mask Rule Check (MRC) rules as well as serve as baseline conditions for future process improvement. We utilize Advanced Mask Characterization (AMC) techniques to understand process capability on designs of varying complexity that include EUV OPC models with and without sub-resolution assist features (SRAFs). Through these collaborations, we demonstrate ways to develop EUV processes and reduce implementation risks for eventual mass production. By reducing these risks, we hope to expand access to EUV mask capability for the broadest community possible as the technology is implemented first within and then beyond the initial early adopters.

  15. Feature saliency in judging the sex and familiarity of faces.

    PubMed

    Roberts, T; Bruce, V

    1988-01-01

    Two experiments are reported on the effect of feature masking on judgements of the sex and familiarity of faces. In experiment 1 the effect of masking the eyes, nose, or mouth of famous and nonfamous, male and female faces on response times in two tasks was investigated. In the first, recognition, task only masking of the eyes had a significant effect on response times. In the second, sex-judgement, task masking of the nose gave rise to a significant and large increase in response times. In experiment 2 it was found that when facial features were presented in isolation in a sex-judgement task, responses to noses were at chance level, unlike those for eyes or mouths. It appears that visual information available from the nose in isolation from the rest of the face is not sufficient for sex judgement, yet masking of the nose may disrupt the extraction of information about the overall topography of the face, information that may be more useful for sex judgement than for identification of a face.

  16. Unmasking the effects of masking on performance: The potential of multiple-voice masking in the office environment.

    PubMed

    Keus van de Poll, Marijke; Carlsson, Johannes; Marsh, John E; Ljung, Robert; Odelius, Johan; Schlittmeier, Sabine J; Sundin, Gunilla; Sörqvist, Patrik

    2015-08-01

    Broadband noise is often used as a masking sound to combat the negative consequences of background speech on performance in open-plan offices. As office workers generally dislike broadband noise, it is important to find alternatives that are more appreciated while being at least not less effective. The purpose of experiment 1 was to compare broadband noise with two alternatives-multiple voices and water waves-in the context of a serial short-term memory task. A single voice impaired memory in comparison with silence, but when the single voice was masked with multiple voices, performance was on level with silence. Experiment 2 explored the benefits of multiple-voice masking in more detail (by comparing one voice, three voices, five voices, and seven voices) in the context of word processed writing (arguably a more office-relevant task). Performance (i.e., writing fluency) increased linearly from worst performance in the one-voice condition to best performance in the seven-voice condition. Psychological mechanisms underpinning these effects are discussed.

  17. Perceptual learning for speech in noise after application of binary time-frequency masks

    PubMed Central

    Ahmadi, Mahnaz; Gross, Vauna L.; Sinex, Donal G.

    2013-01-01

    Ideal time-frequency (TF) masks can reject noise and improve the recognition of speech-noise mixtures. An ideal TF mask is constructed with prior knowledge of the target speech signal. The intelligibility of a processed speech-noise mixture depends upon the threshold criterion used to define the TF mask. The study reported here assessed the effect of training on the recognition of speech in noise after processing by ideal TF masks that did not restore perfect speech intelligibility. Two groups of listeners with normal hearing listened to speech-noise mixtures processed by TF masks calculated with different threshold criteria. For each group, a threshold criterion that initially produced word recognition scores between 0.56–0.69 was chosen for training. Listeners practiced with one set of TF-masked sentences until their word recognition performance approached asymptote. Perceptual learning was quantified by comparing word-recognition scores in the first and last training sessions. Word recognition scores improved with practice for all listeners with the greatest improvement observed for the same materials used in training. PMID:23464038

  18. Critical ratios of beluga whales (Delphinapterus leucas) and masked signal duration.

    PubMed

    Erbe, Christine

    2008-10-01

    This article examines the masking of a complex beluga vocalization by natural and anthropogenic noise. The call consisted of six 150 ms pulses exhibiting spectral peaks between 800 Hz and 8 kHz. Comparing the spectra and spectrograms of the call and noises at detection threshold showed that the animal did not hear the entire call at threshold. It only heard parts of the call in frequency and time. From the masked hearing thresholds in broadband continuous noises, critical ratios were computed. Fletcher critical bands were narrower than either 15 or 111 of an octave at the low frequencies of the call (<2 kHz), depending on which frequency the animal cued on. From the masked hearing thresholds in intermittent noises, the audible signal duration at detection threshold was computed. The intermittent noises differed in gap length, gap number, and masking, but the total audible signal duration at threshold was the same: 660 ms. This observation supports a multiple-looks model. The two amplitude modulated noises exhibited weaker masking than the unmodulated noises hinting at a comodulation masking release.

  19. Characteristics and issues of an EUVL mask applying phase-shifting thinner absorber for device fabrication

    NASA Astrophysics Data System (ADS)

    Seo, Hwan-Seok; Lee, Dong-Gun; Ahn, Byung-Sup; Han, Hakseung; Huh, Sungmin; Kang, In-Yong; Kim, Hoon; Kim, Dongwan; Kim, Seong-Sue; Cho, Han-Ku

    2009-03-01

    Phase-shifting EUVL masks applying thinner absorber are investigated to design optimum mask structure with less shadowing problems. Simulations using S-Litho show that H-V bias in Si capping structure is higher than that of Ru capping since the high n (= 0.999) of Si increases sensible absorber height. Phase differences obtained from the patterned masks using the EUV CSM are well-matched with the calculated values using the practical refractive index of absorber materials. Although the mask with 62.4-nm-thick absorber, among the in-house masks, shows the closest phase ΔΦ(= 176°) to the out-of-phase condition, higher NILS and contrast as well as lower H-V bias are obtained with 52.4-nm-thick absorber (ΔΦ = 151°) which has higher R/R0 ratio. MET results also show that lithography performances including MEEF, PW, and resist threshold (dose), are improved with thinner absorber structure. However, low OD in EUVL mask, especially in thinner absorber structure, results in light leakage from the neighboring exposure shots, and thus an appropriate light-shielding layer should be introduced.

  20. Evaluation of particulate filtering respirators using inward leakage (IL) or total inward leakage (TIL) testing--Korean experience.

    PubMed

    Han, Don-Hee; Lee, Jinheon

    2005-10-01

    Korean certification regulation for particulate filtering respirators requires inward leakage (IL) or total inward leakage (TIL) testing according to European Standard EN 13274-1, and the standard levels of compliance are similar to those of the European Standard. This study was conducted to evaluate particulate filtering respirators being commercially used in the Korean market using an IL or TIL test and the validity of standard level in Korea. Three half masks and 10 filtering facepieces (two top class, four 1st class and four 2nd class)-a total of 13 brand name respirators-were selected for the test with panels of 10 subjects. Each subject was classified with nine facial dimension grid squares in accordance with face length and lip length. IL or TIL testing was conducted at the laboratory of the 3M Innovation Center in which the experimental instruments and systems were established in compliance with European standards. The testing procedure followed EN 13274-1 (2001). As expected, leakages of half masks were less than those of filtering facepieces and the latter were significantly different among brands. TILs of the 1st class filtering facepieces were found to be much more than those of the 2nd class and the result may cause a wearer to get confused when selecting a mask. The main route leakage for filtering facepieces may not be the filter medium but the face seal. Therefore, it is necessary to develop well-fitting filtering facepieces for Koreans. Because leakages were significantly different for different facial dimensions, a defined test panel for IL or TIL testing according to country or race should be developed. A more precise method to demonstrate fit, for example, fit testing such as in the US regulations, will be needed before IL or TIL testing or when selecting a respirator. Another finding implies that geometric mean of five exercises for IL or TIL may be better than arithmetic mean to establish a standard individual subject mean.

  1. Pressure effects on the nose by an in-flight oxygen mask during simulated flight conditions.

    PubMed

    Schreinemakers, J Rieneke C; Boer, C; van Amerongen, P C G M; Kon, M

    2016-12-01

    Dutch F-16 fighter pilots experience oxygen mask inflicted nasal trauma, including discomfort, pain, skin abrasions, bruises and bone remodelling. Pressure and shear forces on the nose might contribute to causing these adverse effects. In this study, it was evaluated how flight conditions affected the exerted pressure, and whether shear forces were present. The pressure exerted by the oxygen mask was measured in 20 volunteers by placing pressure sensors on the nose and chin underneath the mask. In the human centrifuge, the effects on the exerted pressure during different flight conditions were evaluated (+3G z , +6G z , +9G z , protocolised head movements, mounted visor or night vision goggles, NVG). The runs were recorded to evaluate if the mask's position changed during the run, which would confirm the presence of shear forces. Head movements increased the median pressure on the nose by 50 mm Hg and on the chin by 37 mm Hg. NVG, a visor and accelerative forces also increased the median pressure on the nose. Pressure drops on the nose were also observed, during mounted NVG (-63 mm Hg). The recordings showed the mask slid downwards, especially during the acceleration phase of the centrifuge run, signifying the presence of shear forces. The exerted pressure by the oxygen mask changes during different flight conditions. Exposure to changing pressures and to shear forces probably contributes to mask-inflicted nasal trauma. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://www.bmj.com/company/products-services/rights-and-licensing/.

  2. In-vivo heat retention comparison of eyelid warming masks.

    PubMed

    Bitton, Etty; Lacroix, Zoé; Léger, Stéphanie

    2016-08-01

    Meibomian gland dysfunction (MGD) is one of the most common causes of evaporative dry eye. Warm compresses (WC) are recommended as adjunct therapy to slowly transfer heat to the meibomian glands to melt or soften the stagnant meibum with targeted temperatures of 40-45°C. This clinical study evaluated the heat retention profiles of commercially available eyelid warming masks over a 12-min interval. Five eyelid-warming masks (MGDRx Eyebag(®), EyeDoctor(®), Bruder(®), Tranquileyes XR™, Thera°Pearl(®)) were heated following manufacturer's instructions and heat retention was assessed at 1-min intervals for 12min. A facecloth warmed with hot tap water was used as comparison. Twelve (n=12) subjects participated in the study (10F:2M, ranging in age from 21 to 30 with an average of 23.2±3.8years). Each mask demonstrated a unique heat retention profile, reaching maximum temperature at different times and having a different final temperature at the end of the 12-min evaluation. After heating, all eyelid warming masks reached a temperature near 37°C within the first minute. The facecloth was significantly cooler than all other masks as of the 2-min mark (p<0.05). Reusability, availability and heat retention profiles should be considered when selecting an eyelid warming masks for adjunct WC therapy in the management of MGD. All masks tested, with the exception of the facecloth, demonstrated stable heat retention throughout the 12min, bringing further awareness that patient education is required to discuss the shortcomings of the heat retention of the facecloth, if only heated once. Copyright © 2016 British Contact Lens Association. Published by Elsevier Ltd. All rights reserved.

  3. A threshold-based cloud mask for the high-resolution visible channel of Meteosat Second Generation SEVIRI

    NASA Astrophysics Data System (ADS)

    Bley, S.; Deneke, H.

    2013-10-01

    A threshold-based cloud mask for the high-resolution visible (HRV) channel (1 × 1 km2) of the Meteosat SEVIRI (Spinning Enhanced Visible and Infrared Imager) instrument is introduced and evaluated. It is based on operational EUMETSAT cloud mask for the low-resolution channels of SEVIRI (3 × 3 km2), which is used for the selection of suitable thresholds to ensure consistency with its results. The aim of using the HRV channel is to resolve small-scale cloud structures that cannot be detected by the low-resolution channels. We find that it is of advantage to apply thresholds relative to clear-sky reflectance composites, and to adapt the threshold regionally. Furthermore, the accuracy of the different spectral channels for thresholding and the suitability of the HRV channel are investigated for cloud detection. The case studies show different situations to demonstrate the behavior for various surface and cloud conditions. Overall, between 4 and 24% of cloudy low-resolution SEVIRI pixels are found to contain broken clouds in our test data set depending on considered region. Most of these broken pixels are classified as cloudy by EUMETSAT's cloud mask, which will likely result in an overestimate if the mask is used as an estimate of cloud fraction. The HRV cloud mask aims for small-scale convective sub-pixel clouds that are missed by the EUMETSAT cloud mask. The major limit of the HRV cloud mask is the minimum cloud optical thickness (COT) that can be detected. This threshold COT was found to be about 0.8 over ocean and 2 over land and is highly related to the albedo of the underlying surface.

  4. An Off-Axis Four-Quadrant Phase Mask (FQPM) Coronagraph for Palomar: High-Contrast Near Bright Stars Imager

    NASA Technical Reports Server (NTRS)

    Haguenauer, Pierre; Serabyn, Eugene; Bloemhof, Eric E.; Troy, Mitchell; Wallace, James K.; Koresko, Chris D.; Mennesson, Bertrand

    2005-01-01

    Direct detection of planets around nearby stars requires the development of high-contrast imaging techniques because of the high difference between their respective fluxes. This led us to test a new coronagraphic approach based on the use of phase mask instead of dark occulting ones. Combined with high-level wavefront correction on an unobscured off-axis section of a large telescope, this method allows imaging very close to the star. Calculations indicate that for a given ground-based on-axis telescope, use of such an off-axis coronagraph provides a near-neighbor detection capability superior to that of a traditional coronagraph utilizing the full telescope aperture. Setting up a laboratory experiment working in near infrared allowed us to demonstrate the principle of the method, and a rejection of 2000:1 has already been achieved.

  5. A Cloud Mask for AIRS

    NASA Technical Reports Server (NTRS)

    Brubaker, N.; Jedlovec, G. J.

    2004-01-01

    With the preliminary release of AIRS Level 1 and 2 data to the scientific community, there is a growing need for an accurate AIRS cloud mask for data assimilation studies and in producing products derived from cloud free radiances. Current cloud information provided with the AIRS data are limited or based on simplified threshold tests. A multispectral cloud detection approach has been developed for AIRS that utilizes the hyper-spectral capabilities to detect clouds based on specific cloud signatures across the short wave and long wave infrared window regions. This new AIRS cloud mask has been validated against the existing AIRS Level 2 cloud product and cloud information derived from MODIS. Preliminary results for both day and night applications over the continental U.S. are encouraging. Details of the cloud detection approach and validation results will be presented at the conference.

  6. A chronometric exploration of high-resolution 'sensitive TMS masking' effects on subjective and objective measures of vision.

    PubMed

    de Graaf, Tom A; Herring, Jim; Sack, Alexander T

    2011-03-01

    Transcranial magnetic stimulation (TMS) can induce masking by interfering with ongoing neural activity in early visual cortex. Previous work has explored the chronometry of occipital involvement in vision by using single pulses of TMS with high temporal resolution. However, conventionally TMS intensities have been high and the only measure used to evaluate masking was objective in nature. Recent studies have begun to incorporate subjective measures of vision, alongside objective ones. The current study goes beyond previous work in two regards. First, we explored both objective vision (an orientation discrimination task) and subjective vision (a stimulus visibility rating on a four-point scale), across a wide range of time windows with high temporal resolution. Second, we used a very sensitive TMS-masking paradigm: stimulation was at relatively low TMS intensities, with a figure-8 coil, and the small stimulus was difficult to discriminate already at baseline level. We hypothesized that this should increase the effective temporal resolution of our paradigm. Perhaps for this reason, we are able to report a rather interesting masking curve. Within the classical-masking time window, previously reported to encompass broad SOAs anywhere between 60 and 120 ms, we report not one, but at least two dips in objective performance, with no masking in-between. The subjective measure of vision did not mirror this pattern. These preliminary data from our exploratory design suggest that, with sensitive TMS masking, we might be able to reveal visual processes in early visual cortex previously unreported.

  7. Birds and anthropogenic noise: are urban songs adaptive?

    PubMed

    Nemeth, Erwin; Brumm, Henrik

    2010-10-01

    In cities with intense low-frequency traffic noise, birds have been observed to sing louder and at a higher pitch. Several studies argue that higher song pitch is an adaptation to reduce masking from noise, and it has even been suggested that the song divergence between urban and nonurban songs might lead to reproductive isolation. Here we present models of signal transmission to compare the benefits of raised song amplitude and song pitch in terms of sound transmission. We chose two bird species that sing with higher pitch in urban areas, the great tit (Parus major) and the blackbird (Turdus merula). For both species, we calculated communication distances in response to different levels of urban noise and in their natural forest habitats. We found that an increase in vocal pitch increased communication distance only marginally. In contrast, vocal amplitude adjustments had a strong and significantly larger effect. Our results indicate that frequency changes of urban songs are not very effective in mitigating masking from traffic noise. Increased song pitch might not be an adaptation to reduce signal masking but a physiological side effect of singing at high amplitudes or an epiphenomenon of urbanization that is not related to signal transmission.

  8. Processing load induced by informational masking is related to linguistic abilities.

    PubMed

    Koelewijn, Thomas; Zekveld, Adriana A; Festen, Joost M; Rönnberg, Jerker; Kramer, Sophia E

    2012-01-01

    It is often assumed that the benefit of hearing aids is not primarily reflected in better speech performance, but that it is reflected in less effortful listening in the aided than in the unaided condition. Before being able to assess such a hearing aid benefit the present study examined how processing load while listening to masked speech relates to inter-individual differences in cognitive abilities relevant for language processing. Pupil dilation was measured in thirty-two normal hearing participants while listening to sentences masked by fluctuating noise or interfering speech at either 50% and 84% intelligibility. Additionally, working memory capacity, inhibition of irrelevant information, and written text reception was tested. Pupil responses were larger during interfering speech as compared to fluctuating noise. This effect was independent of intelligibility level. Regression analysis revealed that high working memory capacity, better inhibition, and better text reception were related to better speech reception thresholds. Apart from a positive relation to speech recognition, better inhibition and better text reception are also positively related to larger pupil dilation in the single-talker masker conditions. We conclude that better cognitive abilities not only relate to better speech perception, but also partly explain higher processing load in complex listening conditions.

  9. A survey of Alberta physicians' use of and attitudes toward face masks and face shields in the operating room setting.

    PubMed

    Davis, Philip J; Spady, Donald; Forgie, Sarah E D

    2007-09-01

    There is little evidence that surgical mask use by physicians in the operating room (OR) reduces surgical site infections (SSIs), but masks do protect the wearer from potentially infectious splashes. Face shields offer even more protection because they cover the eyes, but they may be perceived as offering less protection to the patient than do masks. The objectives of this study were to ascertain if there were predictors to determine which OR physicians are continuing to use masks and what their reasons are for doing so, and which OR physicians would accept face shields and their reasons for doing so. We surveyed the province of Alberta's surgeons, general practice (GP) surgeons, anesthesiologists, and GP anesthetists to determine how many physicians in the OR wear surgical masks, their reasons for wearing surgical masks (ethical, legal, protection of the patient, protection of the wearer), and if they believe that face shields offer more protection to the patient or to the wearer. We also sought to examine which demographic factors affected their responses. The data were examined with chi(2) analysis to assess the relationships of age and practitioner type, and for various outcome variables. A significance level of P < .05 was accepted as statistically significant. The sex of the physician did not affect his/her responses. Older physicians believe that the OR team has an ethical and legal responsibility to wear surgical masks; masks are worn to prevent the spread of disease, not because it is tradition to do so; masks protect the wearer more than do face shields; and wearing face shields alone will subject the patient to higher rates of SSIs. Surgeons are more likely than are anesthesiologists to wear surgical masks in the OR and wear a surgical mask and a face shield if the patient has risk factors for a blood borne infection. According to our survey, age and profession were the most important variables that affected the potential use of surgical masks and face shields. Younger OR physicians likely would be amenable to using face shields in addition to masks in the OR to protect themselves from exposure to blood or bodily fluids.

  10. "Fell" Primes "Fall", but Does "Bell" Prime "Ball"? Masked Priming with Irregularly-Inflected Primes

    ERIC Educational Resources Information Center

    Crepaldi, Davide; Rastle, Kathleen; Coltheart, Max; Nickels, Lyndsey

    2010-01-01

    Recent masked priming experiments have brought to light a morphological level of analysis that is exclusively based on the orthographic appearance of words, so that it breaks down corner into corn- and -er, as well as dealer into deal- and -er (Rastle, Davis, & New, 2004). Being insensitive to semantic factors, this morpho-orthographic…

  11. Influence of Temporal Expectations on Response Priming by Subliminal Faces

    PubMed Central

    Guex, Raphael; Vuilleumier, Patrik

    2016-01-01

    Unconscious processes are often assumed immune from attention influence. Recent behavioral studies suggest however that the processing of subliminal information can be influenced by temporal attention. To examine the neural mechanisms underlying these effects, we used a stringent masking paradigm together with fMRI to investigate how temporal attention modulates the processing of unseen (masked) faces. Participants performed a gender decision task on a visible neutral target face, preceded by a masked prime face that could vary in gender (same or different than target) and emotion expression (neutral or fearful). We manipulated temporal attention by instructing participants to expect targets to appear either early or late during the stimulus sequence. Orienting temporal attention to subliminal primes influenced response priming by masked faces, even when gender was incongruent. In addition, gender-congruent primes facilitated responses regardless of attention while gender-incongruent primes reduced accuracy when attended. Emotion produced no differential effects. At the neural level, incongruent and temporally unexpected primes increased brain response in regions of the fronto-parietal attention network, reflecting greater recruitment of executive control and reorienting processes. Congruent and expected primes produced higher activations in fusiform cortex, presumably reflecting facilitation of perceptual processing. These results indicate that temporal attention can influence subliminal processing of face features, and thus facilitate information integration according to task-relevance regardless of conscious awareness. They also suggest that task-congruent information between prime and target may facilitate response priming even when temporal attention is not selectively oriented to the prime onset time. PMID:27764124

  12. Influence of Temporal Expectations on Response Priming by Subliminal Faces.

    PubMed

    Pichon, Swann; Guex, Raphael; Vuilleumier, Patrik

    2016-01-01

    Unconscious processes are often assumed immune from attention influence. Recent behavioral studies suggest however that the processing of subliminal information can be influenced by temporal attention. To examine the neural mechanisms underlying these effects, we used a stringent masking paradigm together with fMRI to investigate how temporal attention modulates the processing of unseen (masked) faces. Participants performed a gender decision task on a visible neutral target face, preceded by a masked prime face that could vary in gender (same or different than target) and emotion expression (neutral or fearful). We manipulated temporal attention by instructing participants to expect targets to appear either early or late during the stimulus sequence. Orienting temporal attention to subliminal primes influenced response priming by masked faces, even when gender was incongruent. In addition, gender-congruent primes facilitated responses regardless of attention while gender-incongruent primes reduced accuracy when attended. Emotion produced no differential effects. At the neural level, incongruent and temporally unexpected primes increased brain response in regions of the fronto-parietal attention network, reflecting greater recruitment of executive control and reorienting processes. Congruent and expected primes produced higher activations in fusiform cortex, presumably reflecting facilitation of perceptual processing. These results indicate that temporal attention can influence subliminal processing of face features, and thus facilitate information integration according to task-relevance regardless of conscious awareness. They also suggest that task-congruent information between prime and target may facilitate response priming even when temporal attention is not selectively oriented to the prime onset time.

  13. Comparison of Cloud Detection Using the CERES-MODIS Ed4 and LaRC AVHRR Cloud Masks and CALIPSO Vertical Feature Mask

    NASA Astrophysics Data System (ADS)

    Trepte, Q. Z.; Minnis, P.; Palikonda, R.; Bedka, K. M.; Sun-Mack, S.

    2011-12-01

    Accurate detection of cloud amount and distribution using satellite observations is crucial in determining cloud radiative forcing and earth energy budget. The CERES-MODIS (CM) Edition 4 cloud mask is a global cloud detection algorithm for application to Terra and Aqua MODIS data with the aid of other ancillary data sets. It is used operationally for the NASA's Cloud and Earth's Radiant Energy System (CERES) project. The LaRC AVHRR cloud mask, which uses only five spectral channels, is based on a subset of the CM cloud mask which employs twelve MODIS channels. The LaRC mask is applied to AVHRR data for the NOAA Climate Data Record Program. Comparisons among the CM Ed4, and LaRC AVHRR cloud masks and the CALIPSO Vertical Feature Mask (VFM) constitute a powerful means for validating and improving cloud detection globally. They also help us understand the strengths and limitations of the various cloud retrievals which use either active and passive satellite sensors. In this paper, individual comparisons will be presented for different types of clouds over various surfaces, including daytime and nighttime, and polar and non-polar regions. Additionally, the statistics of the global, regional, and zonal cloud occurrence and amount from the CERES Ed4, AVHRR cloud masks and CALIPSO VFM will be discussed.

  14. Mask characterization for critical dimension uniformity budget breakdown in advanced extreme ultraviolet lithography

    NASA Astrophysics Data System (ADS)

    Nikolsky, Peter; Strolenberg, Chris; Nielsen, Rasmus; Nooitgedacht, Tjitte; Davydova, Natalia; Yang, Greg; Lee, Shawn; Park, Chang-Min; Kim, Insung; Yeo, Jeong-Ho

    2013-04-01

    As the International Technology Roadmap for Semiconductors critical dimension uniformity (CDU) specification shrinks, semiconductor companies need to maintain a high yield of good wafers per day and high performance (and hence market value) of finished products. This cannot be achieved without continuous analysis and improvement of on-product CDU as one of the main drivers for process control and optimization with better understanding of main contributors from the litho cluster: mask, process, metrology and scanner. We will demonstrate a study of mask CDU characterization and its impact on CDU Budget Breakdown (CDU BB) performed for advanced extreme ultraviolet (EUV) lithography with 1D (dense lines) and 2D (dense contacts) feature cases. We will show that this CDU contributor is one of the main differentiators between well-known ArFi and new EUV CDU budgeting principles. We found that reticle contribution to intrafield CDU should be characterized in a specific way: mask absorber thickness fingerprints play a role comparable with reticle CDU in the total reticle part of the CDU budget. Wafer CD fingerprints, introduced by this contributor, may or may not compensate variations of mask CDs and hence influence on total mask impact on intrafield CDU at the wafer level. This will be shown on 1D and 2D feature examples. Mask stack reflectivity variations should also be taken into account: these fingerprints have visible impact on intrafield CDs at the wafer level and should be considered as another contributor to the reticle part of EUV CDU budget. We also observed mask error enhancement factor (MEEF) through field fingerprints in the studied EUV cases. Variations of MEEF may play a role towards the total intrafield CDU and may need to be taken into account for EUV lithography. We characterized MEEF-through-field for the reviewed features, with results herein, but further analysis of this phenomenon is required. This comprehensive approach to quantifying the mask part of the overall EUV CDU contribution helps deliver an accurate and integral CDU BB per product/process and litho tool. The better understanding of the entire CDU budget for advanced EUVL nodes achieved by Samsung and ASML helps extend the limits of Moore's Law and to deliver successful implementation of smaller, faster and smarter chips in semiconductor industry.

  15. The role of lines and corners of geometric figures in recognition performance.

    PubMed

    Shevelev, Igor A; Kamenkovich, Viktorina M; Sharaev, George A

    2003-01-01

    A relative role of lines and corners of images of outline geometric figures in recognition performance was studied psychophysically. Probability of correct response to the shape of the whole figure (control) and figures with lines or corners masked to a different extent was compared. Increase in the extent of masking resulted in a drop of recognition performance that was significantly lower for figures without corners, than for figures without part of their lines. The whole 3D figures were recognized better than 2D ones, whereas the opposite relations were observed under conditions of masking. Significant gender difference in a recognition performance was found: men recognize entire and partly masked figures better than women. Possible mechanisms of relatively better recognition of figures with corners than with lines are discussed in connection with finding of high sensitivity of many neurons in the primary visual cortex to line crossing and branching.

  16. Clay facial masks: physicochemical stability at different storage temperatures.

    PubMed

    Zague, Vivian; de Almeida Silva, Diego; Baby, André Rolim; Kaneko, Telma Mary; Velasco, Maria Valéria Robles

    2007-01-01

    Clay facial masks--formulations that contain a high percentage of solids dispersed in a liquid vehicle--have become of special interest due to specific properties presented by clays, such as particle size, cooling index, high adsorption capacity, and plasticity. Although most of the physicochemical properties of clay dispersions have been studied, specific aspects concerning the physicochemical stability of clay mask products remain unclear. This work aimed at investigating the accelerated physicochemical stability of clay mask formulations stored at different temperatures. Formulations were subjected to centrifuge testing and to thermal treatment for 15 days, during which temperature was varied from -5.0 degrees to 45.0 degrees C. The apparent viscosity and visual aspect (homogeneity) of all formulations were affected by temperature variation, whereas color, odor, and pH value remained unaltered. These results, besides the estimation of physicochemical stability under aging, can be useful in determining the best storage conditions for clay-based formulations.

  17. Interocular suppression in normal and amblyopic vision: spatio-temporal properties.

    PubMed

    Huang, Pi-Chun; Baker, Daniel H; Hess, Robert F

    2012-10-31

    We measured the properties of interocular suppression in strabismic amblyopes and compared these to dichoptic masking in binocularly normal observers. We used a dichoptic version of the well-established probed-sinewave paradigm that measured sensitivity to a brief target stimulus (one of four letters to be discriminated) in the amblyopic eye at different times relative to a suppression-inducing mask in the fixing eye. This was done using both sinusoidal steady state and transient approaches. The suppression-inducing masks were either modulations of luminance or contrast (full field, just overlaying the target, or just surrounding the target). Our results were interpreted using a descriptive model that included contrast gain control and spatio-temporal filtering prior to excitatory binocular combination. The suppression we measured, other than in magnitude, was not fundamentally different from normal dichoptic masking: lowpass spatio-temporal properties with similar contributions from both surround and overlay suppression.

  18. An interference-based optical authentication scheme using two phase-only masks with different diffraction distances

    NASA Astrophysics Data System (ADS)

    Lu, Dajiang; He, Wenqi; Liao, Meihua; Peng, Xiang

    2017-02-01

    A new method to eliminate the security risk of the well-known interference-based optical cryptosystem is proposed. In this method, which is suitable for security authentication application, two phase-only masks are separately placed at different distances from the output plane, where a certification image (public image) can be obtained. To further increase the security and flexibility of this authentication system, we employ one more validation image (secret image), which can be observed at another output plane, for confirming the identity of the user. Only if the two correct masks are properly settled at their positions one could obtain two significant images. Besides, even if the legal users exchange their masks (keys), the authentication process will fail and the authentication results will not reveal any information. Numerical simulations are performed to demonstrate the validity and security of the proposed method.

  19. A cocktail-party listening experiment with children

    NASA Astrophysics Data System (ADS)

    Wightman, Frederic; Callahan, Michael; Kistler, Doris

    2003-04-01

    In an experiment modeled after one reported recently by Brungart and Simpson [J. Acoust. Soc. Am. 112, 2985-2995 (2002)], 38 children (ages 4-16) and 10 adults responded to a monaural target speech signal in the presence of one or two distracter speech signals. The target speaker was a male and the distracter speakers were females. When two distracters were present they were in different ears. Performance at several different target ear S/N was measured and psychometric functions were fitted to estimate threshold, or the 50% performance level. The youngest children required approximately 20 dB higher S/N than adults to achieve threshold with a single distracter. This difference disappeared by age 16. The impact of adding the contralateral distracter, which is thought to contribute only informational masking, was roughly constant across age, however. Adult thresholds increased about 11 dB and the thresholds for the youngest children increased about 10 dB. This was surprising given previous experiments that showed much larger informational masking effects in young children. Also inconsistent with previous results is the lack of individual differences. Nearly all listeners showed almost the same contralateral distracter effect. [Work supported by NICHD.

  20. The Mask Designs for Space Interferometer Mission (SIM)

    NASA Technical Reports Server (NTRS)

    Wang, Xu

    2008-01-01

    The Space Interferometer Mission (SIM) consists of three interferometers (science, guide1, and guide2) and two optical paths (metrology and starlight). The system requirements for each interferometer/optical path combination are different and sometimes work against each other. A diffraction model is developed to design and optimize various masks to simultaneously meet the system requirements of three interferometers. In this paper, the details of this diffraction model will be described first. Later, the mask design for each interferometer will be presented to demonstrate the system performance compliance. In the end, a tolerance sensitivity study on the geometrical dimension, shape, and the alignment of these masks will be discussed.

Top