Sample records for mass screening test

  1. [Evaluation of the usefulness for neonatal mass screening in light of 35 years personal experience].

    PubMed

    Bozkowa, K; Cabalska, B; Radomyska, B; Ołtarzewski, M; Lenartowska, I

    1999-01-01

    The results and the significance of neonatal mass-screening programmes for inborn errors of metabolism, conducted by the National Research Institute of Mother and Child (NRIMC), are discussed. As the first in Poland, in 1964, mass-screening for phenylketonuria (PKU) was introduced. The BIA-Guthrie test was used. Other Guthrie tests (GBIA) were applied in homocystinuria, tyrosinemia, histidinemia and leucinosis (Maple Syrup Urine Disease-MSUD). In the middle of the 60. the Beutler and Baluda test was introduced for galactosaemia, as well as the Efron urine test in infant screening for different inborn errors of metabolism. In the middle of the 70., neonatal mass-screening for cystic fibrosis (CF, mucoviscidosis) was started. Meconium tests and the sweat test with ion selective chloride electrode were used. Apart from inborn errors of metabolism, we also introduced a screening programme for neuroblastoma in which vaniline mandelic acid (VMA) in urine was estimated and for congenital hypothyroidism were TSH level was assessed. The results of screening are shown in the tables and in the figures. In our opinion the best clinical results are obtained with screening for congenital hypothyroidism and for PKU, since very early detection and treatment in these diseases prevents severe mental retardation. We therefore consider that both these screening programmes should be treated as obligatory examinations in all neonates. Taking into consideration the fact that there are different types of hyperhenylalaninemias, the principles of differential diagnosis are discussed. Molecular genetic investigations, carried out in the NRIMC Department of Genetics proved to be a very important procedure in the verification of diagnosis of different mutations. The authors also discuss the problem of dietary treatment duration in PKU. In our opinion the hypophenyloalanine diet regimen in girls, should not be discontinued during adolescence, since there is the problem of maternal PKU and the possibility of foetal damage. The results of our own investigations of maternal PKU are discussed. The significance of mass-screening for galactosemia is still under discussion. In our opinion, mass-screening for galactosemia is not useful and we have discontinued it. Selective screening has been started combined with molecular genetic studies in high risk families. In the future, we plan to prepare guidelines on the principles of diagnosis and treatment of galactosemia in children and women in the reproductive age. Mass-screening for cystic fibrosis is also still under discussion. The results of the early screening programmes were not satisfactory and the tests were discontinued. In 1998, after reorganisation of the whole system, CF screening, using tripsin-radioimmune assays, was started again. The new screening programme is combined with molecular genetic investigation of different mutations. It is still too early to assess the importance and success of this CF mass-screening programme. We decided to discontinue the screening for homocystinuria, histidinemia, tyrosinemia, leucinosis and for neuroblastoma, since these programmes did not comply with criteria of mass-screening. In 1997, major reorganisation of screening programmes for inborn errors of metabolism, at NRIMC, was undertaken. The Guthrie test for PKU was changed to a quantitative colorimetric method. The immuno-luminometric method is used for TSH estimation. The whole system is based on complete computer control of all the steps of screening, from blood sampling on filter paper until the final diagnosis. The advantages of this modern system of organisation of the screening programme are discussed.

  2. 21 CFR 862.1055 - Newborn screening test system for amino acids, free carnitine, and acylcarnitines using tandem...

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... mass spectrometry is a device that consists of stable isotope internal standards, control materials..., free carnitine, and acylcarnitines using tandem mass spectrometry. 862.1055 Section 862.1055 Food and... screening test system for amino acids, free carnitine, and acylcarnitines using tandem mass spectrometry. (a...

  3. 21 CFR 862.1055 - Newborn screening test system for amino acids, free carnitine, and acylcarnitines using tandem...

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... mass spectrometry is a device that consists of stable isotope internal standards, control materials..., free carnitine, and acylcarnitines using tandem mass spectrometry. 862.1055 Section 862.1055 Food and... screening test system for amino acids, free carnitine, and acylcarnitines using tandem mass spectrometry. (a...

  4. Mass media campaign improves cervical screening across all socio-economic groups.

    PubMed

    Anderson, Jenny O; Mullins, Robyn M; Siahpush, Mohammad; Spittal, Matthew J; Wakefield, Melanie

    2009-10-01

    Low socio-economic status (SES) has been associated with lower cervical screening rates. Mass media is one known strategy that can increase cervical screening participation. This study sought to determine whether a mass media campaign conducted in Victoria, Australia, in 2005 was effective in encouraging women across all SES groups to screen. Data were obtained from the Victorian Cervical Cytology Registry for each Pap test registered during 2005 and categorized into SES quintiles using the Index of Socio-Economic Advantage/Disadvantage. Negative binomial regression was used to determine the impact of the campaign on the weekly number of Pap tests and whether the media campaign had a differential effect by SES, after adjusting for the number of workdays per week, age group and time since previous test. Cervical screening increased 27% during the campaign period and was equally effective in encouraging screening across all SES groups, including low-SES women. Mass media campaigns can prompt increased rates of cervical screening among all women, not just those from more advantaged areas. Combining media with additional strategies targeted at low-SES women may help lessen the underlying differences in screening rates across SES.

  5. Comprehensive Urine Drug Screen by Gas Chromatography/Mass Spectrometry (GC/MS).

    PubMed

    Ramoo, Bheemraj; Funke, Melissa; Frazee, Clint; Garg, Uttam

    2016-01-01

    Drug screening is an essential component of clinical toxicology laboratory service. Some laboratories use only automated chemistry analyzers for limited screening of drugs of abuse and few other drugs. Other laboratories use a combination of various techniques such as immunoassays, colorimetric tests, and mass spectrometry to provide more detailed comprehensive drug screening. Mass spectrometry, gas or liquid, can screen for hundreds of drugs and is often considered the gold standard for comprehensive drug screening. We describe an efficient and rapid gas chromatography/mass spectrometry (GC/MS) method for comprehensive drug screening in urine which utilizes a liquid-liquid extraction, sample concentration, and analysis by GC/MS.

  6. 21 CFR 862.1055 - Newborn screening test system for amino acids, free carnitine, and acylcarnitines using tandem...

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Newborn screening test system for amino acids... screening test system for amino acids, free carnitine, and acylcarnitines using tandem mass spectrometry. (a) Identification. A newborn screening test system for amino acids, free carnitine, and acylcarnitines using tandem...

  7. 21 CFR 862.1055 - Newborn screening test system for amino acids, free carnitine, and acylcarnitines using tandem...

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Newborn screening test system for amino acids... screening test system for amino acids, free carnitine, and acylcarnitines using tandem mass spectrometry. (a) Identification. A newborn screening test system for amino acids, free carnitine, and acylcarnitines using tandem...

  8. Cost and Efficacy Assessment of an Alternative Medication Compliance Urine Drug Testing Strategy.

    PubMed

    Doyle, Kelly; Strathmann, Frederick G

    2017-02-01

    This study investigates the frequency at which quantitative results provide additional clinical benefit compared to qualitative results alone. A comparison between alternative urine drug screens and conventional screens including the assessment of cost-to-payer differences, accuracy of prescription compliance or polypharmacy/substance abuse was also included. In a reference laboratory evaluation of urine specimens from across the United States, 213 urine specimens with provided prescription medication information (302 prescriptions) were analyzed by two testing algorithms: 1) conventional immunoassay screen with subsequent reflexive testing of positive results by quantitative mass spectrometry; and 2) a combined immunoassay/qualitative mass-spectrometry screen that substantially reduced the need for subsequent testing. The qualitative screen was superior to immunoassay with reflex to mass spectrometry in confirming compliance per prescription (226/302 vs 205/302), and identifying non-prescription abuse (97 vs 71). Pharmaceutical impurities and inconsistent drug metabolite patterns were detected in only 3.8% of specimens, suggesting that quantitative results have limited benefit. The percentage difference between the conventional testing algorithm and the alternative screen was projected to be 55%, and a 2-year evaluation of test utilization as a measure of test order volume follows an exponential trend for alternative screen test orders over conventional immunoassay screens that require subsequent confirmation testing. Alternative, qualitative urine drug screens provide a less expensive, faster, and more comprehensive evaluation of patient medication compliance and drug abuse. The vast majority of results were interpretable with qualitative results alone indicating a reduced need to automatically reflex to quantitation or provide quantitation for the majority of patients. This strategy highlights a successful approach using an alternative strategy for both the laboratory and physician to align clinical needs while being mindful of costs.

  9. Cost-Effectiveness between Double and Single Fecal Immunochemical Test(s) in a Mass Colorectal Cancer Screening.

    PubMed

    Cai, Shan-Rong; Zhu, Hong-Hong; Huang, Yan-Qin; Li, Qi-Long; Ma, Xin-Yuan; Zhang, Su-Zhan; Zheng, Shu

    2016-01-01

    This study investigated the cost-effectiveness between double and single Fecal Immunochemical Test(s) (FIT) in a mass CRC screening. A two-stage sequential screening was conducted. FIT was used as a primary screening test and recommended twice by an interval of one week at the first screening stage. We defined the first-time FIT as FIT1 and the second-time FIT as FIT2. If either FIT1 or FIT2 was positive (+), then a colonoscopy was recommended at the second stage. Costs were recorded and analyzed. A total of 24,419 participants completed either FIT1 or FIT2. The detection rate of advanced neoplasm was 19.2% among both FIT1+ and FIT2+, especially high among men with age ≥55 (27.4%). About 15.4% CRC, 18.9% advanced neoplasm, and 29.9% adenoma missed by FIT1 were detected by FIT2 alone. Average cost was $2,935 for double FITs and $2,121 for FIT1 to detect each CRC and $901 for double FITs and $680 for FIT1 to detect each advanced neoplasm. Double FITs are overall more cost-effective, having significantly higher positive and detection rates with an acceptable higher cost, than single FIT. Double FITs should be encouraged for the first screening in a mass CRC screening, especially in economically and medically underserved populations/areas/countries.

  10. Mass Screening: An Aid to Competency Based Program Development.

    ERIC Educational Resources Information Center

    Siehl, Peterann M.; Studer, Jeannine

    Adolescent suicide is the second leading cause of death in the adolescent population and is on the rise. This study used a mass screening concept as a pre-test identifier of at risk clients for suicide ideation and depressions; development of a competency-based prevention group treatment program, and the post-testing of the identified at-risk…

  11. Outcomes from a mass media campaign to promote cervical screening in NSW, Australia.

    PubMed

    Morrell, Stephen; Perez, Donna A; Hardy, Margaret; Cotter, Trish; Bishop, James F

    2010-09-01

    Despite the decline in the incidence of cervical cancer in Australia as a result of population screening, a substantial proportion of women in NSW screen less regularly than the recommended two-yearly interval or do not screen. With higher rates of cervical cancer in unscreened and underscreened women, and despite the introduction of the human papillomavirus vaccine, there remains a need to continue to remind women to screen. The mass media has been shown to be effective at improving participation in cervical screening. A 2007 television advertising campaign to promote cervical screening in New South Wales (NSW) was examined. Data from the NSW Papanicolaou (Pap) Test Register were used to compare weekly numbers of Pap tests for NSW overall and in metropolitan local government areas with low screening rates by age group and by time since the last Pap test. Time series regression analysis incorporating seasonal effects was used to estimate the strength of the association between screening and the media campaign. Overall during the advertising campaign, 15% more screens (16 700) occurred than expected for 2007 without the advertising campaign. Increases were evident among unscreened and underscreened women, with little overscreening occurring. Women living in low screening areas also showed a significant increase in mean weekly screens of 21% (388) over that expected in the absence of the media campaign. Despite the ecological nature of this study, the mass media campaign appears to have been successful in increasing screening in unscreened and underscreened women in NSW.

  12. Hog Charm II tetracycline test screening results compared with a liquid chromatography tandem mass spectrometry 10-μg/kg method.

    PubMed

    Salter, Robert; Holmes, Steven; Legg, David; Coble, Joel; George, Bruce

    2012-02-01

    Pork tissue samples that tested positive and negative by the Charm II tetracycline test screening method in the slaughter plant laboratory were tested with the modified AOAC International liquid chromatography tandem mass spectrometry (LC-MS-MS) method 995.09 to determine the predictive value of the screening method at detecting total tetracyclines at 10 μg/kg of tissue, in compliance with Russian import regulations. There were 218 presumptive-positive tetracycline samples of 4,195 randomly tested hogs. Of these screening test positive samples, 83% (182) were positive, >10 μg/kg by LC-MS-MS; 12.8% (28) were false violative, greater than limit of detection (LOD) but <10 μg/kg; and 4.2% (8) were not detected at the LC-MS-MS LOD. The 36 false-violative and not-detected samples represent 1% of the total samples screened. Twenty-seven of 30 randomly selected tetracycline screening negative samples tested below the LC-MS-MS LOD, and 3 samples tested <3 μg/kg chlortetracycline. Results indicate that the Charm II tetracycline test is effective at predicting hogs containing >10 μg/kg total tetracyclines in compliance with Russian import regulations.

  13. [The crypto-hem test in screening for colon cancer].

    PubMed

    Prokorov, V V; Shabarov, V L

    1988-01-01

    The paper discusses the reliability of crypto-hem test (detection of occult blood in feces) in diagnosing large bowel tumors in the course of a mass screening. 1573 healthy subjects aged 45 years and older were examined. The results were positive in 24 (2%) out of 1190 screenees who were involved in the test and in 58 (4.9%) subjects the results were suspicious. Tumors were detected in 23 (95.9%) test-positive screenees: cancer--12.5, polyps--54.2 and villous tumor--29.2%. Crypto-hem test proved instrumental in mass screening. Due to its application, symptom-free rectal cancer was diagnosed in 0.2, villous tumor--0.6, and single adenomatous polyps--1.1%.

  14. An Evaluation of Mass Screening Using Fecal Occult Blood Test for Colorectal Cancer in Japan: A Case‐Control Study

    PubMed Central

    Hiwatashi, Nobuo; Morimoto, Tomizo; Fukao, Akira; Sato, Hirofusa; Sugahara, Nobuyuki; Hisamichi, Shigeru; Toyota, Takayoshi

    1993-01-01

    There is as yet no firm evidence showing that mass screening for colorectal cancer using fecal occult blood tests (FOBTs) reduces the mortality from this cancer. Therefore we evaluated the effectiveness of the screening by a case‐control study in Miyagi Prefecture, Japan. The study included as case subjects 28 individuals who had died from colorectal cancer and had had an opportunity to participate in the mass screening before the date of diagnosis as colorectal cancer, and 3 controls for each case subject randomly selected from residents who were alive on the date of death of case subjects and matched by sex, age (within 3 years) and living area using residential files. For each set, i.e., a case subject and 3 controls, screening histories before the date of the diagnosis of the case as colorectal cancer were examined. Both the case subjects and the controls who had participated in the screening at least once within 3 years before the date of diagnosis of the case were classified as “screened.” The 28 case subjects consisted of 12 males and 16 females (average age: 60.8 years). The odds ratio of death from colorectal cancer for the screened versus the non‐screened persons was 0.24 (95% confidence interval = 0.08–0.76) by the Mantel‐Haenszel method. The present study suggests that mass screening using FOBTs for colorectal cancer significantly reduces the mortality from this cancer epidemiologically. PMID:8276715

  15. Who attends a UK diabetes screening programme? Findings from the ADDITION-Cambridge study.

    PubMed

    Sargeant, L A; Simmons, R K; Barling, R S; Butler, R; Williams, K M; Prevost, A T; Kinmonth, A L; Wareham, N J; Griffin, S J

    2010-09-01

    One of the factors influencing the cost-effectiveness of population screening for Type 2 diabetes may be uptake. We examined attendance and practice- and individual-level factors influencing uptake at each stage of a diabetes screening programme in general practice. A stepwise screening programme was undertaken among 135, 825 people aged 40-69 years without known diabetes in 49 general practices in East England. The programme included a score based on routinely available data (age, sex, body mass index and prescribed medication) to identify those at high risk, who were offered random capillary blood glucose (RBG) and glycosylated haemoglobin tests. Those screening positive were offered fasting capillary blood glucose (FBG) and confirmatory oral glucose tolerance tests (OGTT). There were 33 539 high-risk individuals invited for a RBG screening test; 24 654 (74%) attended. Ninety-four per cent attended the follow-up FBG test and 82% the diagnostic OGTT. Seventy per cent of individuals completed the screening programme. Practices with higher general practitioner staff complements and those located in more deprived areas had lower uptake for RBG and FBG tests. Male sex and a higher body mass index were associated with lower attendance for RBG testing. Older age, prescription of antihypertensive medication and a higher risk score were associated with higher attendance for FBG and RBG tests. High attendance rates can be achieved by targeted stepwise screening of individuals assessed as high risk by data routinely available in general practice. Different strategies may be required to increase initial attendance, ensure completion of the screening programme, and reduce the risk that screening increases health inequalities.

  16. Real-time detection method and system for identifying individual aerosol particles

    DOEpatents

    Gard, Eric E [San Francisco, CA; Coffee, Keith R [Patterson, CA; Frank, Matthias [Oakland, CA; Tobias, Herbert J [Kensington, CA; Fergenson, David P [Alamo, CA; Madden, Norm [Livermore, CA; Riot, Vincent J [Berkeley, CA; Steele, Paul T [Livermore, CA; Woods, Bruce W [Livermore, CA

    2007-08-21

    An improved method and system of identifying individual aerosol particles in real time. Sample aerosol particles are collimated, tracked, and screened to determine which ones qualify for mass spectrometric analysis based on predetermined qualification or selection criteria. Screening techniques include one or more of determining particle size, shape, symmetry, and fluorescence. Only qualifying particles passing all screening criteria are subject to desorption/ionization and single particle mass spectrometry to produce corresponding test spectra, which is used to determine the identities of each of the qualifying aerosol particles by comparing the test spectra against predetermined spectra for known particle types. In this manner, activation cycling of a particle ablation laser of a single particle mass spectrometer is reduced.

  17. Eliciting population preferences for mass colorectal cancer screening organization.

    PubMed

    Nayaradou, Maximilien; Berchi, Célia; Dejardin, Olivier; Launoy, Guy

    2010-01-01

    The implementation of mass colorectal cancer (CRC) screening is a public health priority. Population participation is fundamental for the success of CRC screening as for any cancer screening program. The preferences of the population may influence their likelihood of participation. The authors sought to elicit population preferences for CRC screening test characteristics to improve the design of CRC screening campaigns. A discrete choice experiment was used. Questionnaires were compiled with a set of pairs of hypothetical CRC screening scenarios. The survey was conducted by mail from June 2006 to October 2006 on a representative sample of 2000 inhabitants, aged 50 to 74 years from the northwest of France, who were randomly selected from electoral lists. Questionnaires were sent to 2000 individuals, each of whom made 3 or 4 discrete choices between hypothetical tests that differed in 7 attributes: how screening is offered, process, sensitivity, rate of unnecessary colonoscopy, expected mortality reduction, method of screening test result transmission, and cost. Complete responses were received from 656 individuals (32.8%). The attributes that influenced population preferences included expected mortality reduction, sensitivity, cost, and process. Participants from high social classes were particularly influenced by sensitivity. The results demonstrate that the discrete choice experiment provides information on patient preferences for CRC screening: improving screening program effectiveness, for instance, by improving test sensitivity (the most valued attribute) would increase satisfaction among the general population with regard to CRC screening programs. Additional studies are required to study how patient preferences actually affect adherence to regular screening programs.

  18. When does mass screening for open neural tube defects in low-risk pregnancies result in cost savings?

    PubMed Central

    Tosi, L L; Detsky, A S; Roye, D P; Morden, M L

    1987-01-01

    Using a decision analysis model, we estimated the savings that might be derived from a mass prenatal screening program aimed at detecting open neural tube defects (NTDs) in low-risk pregnancies. Our baseline analysis showed that screening v. no screening could be expected to save approximately $8 per pregnancy given a cost of $7.50 for the maternal serum alpha-feto-protein (MSAFP) test and a cost of $42,507 for hospital and rehabilitation services for the first 10 years of life for a child with spina bifida. When a more liberal estimate of the costs of caring for such a child was used, the savings with the screening program were more substantial. We performed extensive sensitivity analyses, which showed that the savings were somewhat sensitive to the cost of the MSAFP test and highly sensitive to the specificity (but not the sensitivity) of the test. A screening program for NTDs in low-risk pregnancies may result in substantial savings in direct health care costs if the screening protocol is followed rigorously and efficiently. PMID:2433011

  19. Steroid profiling for congenital adrenal hyperplasia by tandem mass spectrometry as a second-tier test reduces follow-up burdens in a tertiary care hospital: a retrospective and prospective evaluation.

    PubMed

    Seo, Ja Young; Park, Hyung-Doo; Kim, Jong Won; Oh, Hyeon Ju; Yang, Jeong Soo; Chang, Yun Sil; Park, Won Soon; Lee, Soo-Youn

    2014-01-01

    Newborn screening for congenital adrenal hyperplasia (CAH) based on measuring 17-hydroxyprogesterone (17-OHP) by immunoassay generates a number of false-positive results, especially in preterm neonates. We applied steroid profiling by using liquid chromatography-tandem mass spectrometry (LC-MS/MS) as a second-tier test in newborns with positive CAH screening and evaluated its clinical utility in a tertiary care hospital setting. By performing a 4-year retrospective data review, we were able to test 121 dried blood spots from newborns with positive CAH screening for 17-OHP, androstenedione and cortisol levels by LC-MS/MS. We prospectively evaluated the clinical utility of steroid profiling after the implementation of steroid profiling as a second-tier test in our routine clinical practice. During the 2-year prospective study period, 104 cases with positive initial screening by FIA were tested by LC-MS/MS. Clinical and laboratory follow-up were performed for at least 6 months. The preterm neonates accounted for 50.7% (76/150) and 70.4% (88/125) of screening-positive cases in retrospective and prospective cohorts, respectively. By applying steroid profiling as a second-tier test for positive CAH screening, we eliminated all false-positive results and decreased the median follow-up time from 75 to 8 days. Our data showed that steroid profiling reduced the burden of follow-up exams by improving the positive predictive value of the CAH screening program. The use of steroid profiling as a second-tier test for positive CAH screening will improve clinical practice particularly in a tertiary care hospital setting where positive CAH screening from preterm neonates is frequently encountered.

  20. Making the Case for Objective Performance Metrics in Newborn Screening by Tandem Mass Spectrometry

    ERIC Educational Resources Information Center

    Rinaldo, Piero; Zafari, Saba; Tortorelli, Silvia; Matern, Dietrich

    2006-01-01

    The expansion of newborn screening programs to include multiplex testing by tandem mass spectrometry requires understanding and close monitoring of performance metrics. This is not done consistently because of lack of defined targets, and interlaboratory comparison is almost nonexistent. Between July 2004 and April 2006 (N = 176,185 cases), the…

  1. Expanded newborn screening by mass spectrometry: New tests, future perspectives.

    PubMed

    Ombrone, Daniela; Giocaliere, Elisa; Forni, Giulia; Malvagia, Sabrina; la Marca, Giancarlo

    2016-01-01

    Tandem mass spectrometry (MS/MS) has become a leading technology used in clinical chemistry and has shown to be particularly sensitive and specific when used in newborn screening (NBS) tests. The success of tandem mass spectrometry is due to important advances in hardware, software and clinical applications during the last 25 years. MS/MS permits a very rapid measurement of many metabolites in different biological specimens by using filter paper spots or directly on biological fluids. Its use in NBS give us the chance to identify possible treatable metabolic disorders even when asymptomatic and the benefits gained by this type of screening is now recognized worldwide. Today the use of MS/MS for second-tier tests and confirmatory testing is promising especially in the early detection of new disorders such as some lysosomal storage disorders, ADA and PNP SCIDs, X-adrenoleucodistrophy (X-ALD), Wilson disease, guanidinoacetate methyltransferase deficiency (GAMT), and Duchenne muscular dystrophy. The new challenge for the future will be reducing the false positive rate by using second-tier tests, avoiding false negative results by using new specific biomarkers and introducing new treatable disorders in NBS programs. © 2015 Wiley Periodicals, Inc.

  2. The cost-effectiveness of 10 antenatal syphilis screening and treatment approaches in Peru, Tanzania, and Zambia.

    PubMed

    Terris-Prestholt, Fern; Vickerman, Peter; Torres-Rueda, Sergio; Santesso, Nancy; Sweeney, Sedona; Mallma, Patricia; Shelley, Katharine D; Garcia, Patricia J; Bronzan, Rachel; Gill, Michelle M; Broutet, Nathalie; Wi, Teodora; Watts, Charlotte; Mabey, David; Peeling, Rosanna W; Newman, Lori

    2015-06-01

    Rapid plasma reagin (RPR) is frequently used to test women for maternal syphilis. Rapid syphilis immunochromatographic strip tests detecting only Treponema pallidum antibodies (single RSTs) or both treponemal and non-treponemal antibodies (dual RSTs) are now available. This study assessed the cost-effectiveness of algorithms using these tests to screen pregnant women. Observed costs of maternal syphilis screening and treatment using clinic-based RPR and single RSTs in 20 clinics across Peru, Tanzania, and Zambia were used to model the cost-effectiveness of algorithms using combinations of RPR, single, and dual RSTs, and no and mass treatment. Sensitivity analyses determined drivers of key results. Although this analysis found screening using RPR to be relatively cheap, most (>70%) true cases went untreated. Algorithms using single RSTs were the most cost-effective in all observed settings, followed by dual RSTs, which became the most cost-effective if dual RST costs were halved. Single test algorithms dominated most sequential testing algorithms, although sequential algorithms reduced overtreatment. Mass treatment was relatively cheap and effective in the absence of screening supplies, though treated many uninfected women. This analysis highlights the advantages of introducing RSTs in three diverse settings. The results should be applicable to other similar settings. Copyright © 2015 International Federation of Gynecology and Obstetrics. All rights reserved.

  3. The cost-effectiveness of 10 antenatal syphilis screening and treatment approaches in Peru, Tanzania, and Zambia

    PubMed Central

    Terris-Prestholt, Fern; Vickerman, Peter; Torres-Rueda, Sergio; Santesso, Nancy; Sweeney, Sedona; Mallma, Patricia; Shelley, Katharine D.; Garcia, Patricia J.; Bronzan, Rachel; Gill, Michelle M.; Broutet, Nathalie; Wi, Teodora; Watts, Charlotte; Mabey, David; Peeling, Rosanna W.; Newman, Lori

    2015-01-01

    Objective Rapid plasma reagin (RPR) is frequently used to test women for maternal syphilis. Rapid syphilis immunochromatographic strip tests detecting only Treponema pallidum antibodies (single RSTs) or both treponemal and non-treponemal antibodies (dual RSTs) are now available. This study assessed the cost-effectiveness of algorithms using these tests to screen pregnant women. Methods Observed costs of maternal syphilis screening and treatment using clinic-based RPR and single RSTs in 20 clinics across Peru, Tanzania, and Zambia were used to model the cost-effectiveness of algorithms using combinations of RPR, single, and dual RSTs, and no and mass treatment. Sensitivity analyses determined drivers of key results. Results Although this analysis found screening using RPR to be relatively cheap, most (> 70%) true cases went untreated. Algorithms using single RSTs were the most cost-effective in all observed settings, followed by dual RSTs, which became the most cost-effective if dual RST costs were halved. Single test algorithms dominated most sequential testing algorithms, although sequential algorithms reduced overtreatment. Mass treatment was relatively cheap and effective in the absence of screening supplies, though treated many uninfected women. Conclusion This analysis highlights the advantages of introducing RSTs in three diverse settings. The results should be applicable to other similar settings. PMID:25963907

  4. Mass spectrometric-based stable isotopic 2-aminobenzoic acid glycan mapping for rapid glycan screening of biotherapeutics.

    PubMed

    Prien, Justin M; Prater, Bradley D; Qin, Qiang; Cockrill, Steven L

    2010-02-15

    Fast, sensitive, robust methods for "high-level" glycan screening are necessary during various stages of a biotherapeutic product's lifecycle, including clone selection, process changes, and quality control for lot release testing. Traditional glycan screening involves chromatographic or electrophoretic separation-based methods, and, although reproducible, these methods can be time-consuming. Even ultrahigh-performance chromatographic and microfluidic integrated LC/MS systems, which work on the tens of minute time scale, become lengthy when hundreds of samples are to be analyzed. Comparatively, a direct infusion mass spectrometry (MS)-based glycan screening method acquires data on a millisecond time scale, exhibits exquisite sensitivity and reproducibility, and is amenable to automated peak annotation. In addition, characterization of glycan species via sequential mass spectrometry can be performed simultaneously. Here, we demonstrate a quantitative high-throughput MS-based mapping approach using stable isotope 2-aminobenzoic acid (2-AA) for rapid "high-level" glycan screening.

  5. Economic implications of three strategies for the control of taeniasis.

    PubMed

    Alexander, Anu; John, K R; Jayaraman, T; Oommen, Anna; Venkata Raghava, M; Dorny, Pierre; Rajshekhar, Vedantam

    2011-11-01

    To evaluate the cost-effectiveness of three strategies for the control of taeniasis in a community, in terms of cost per case treated. A study was conducted in South India to determine the prevalence of taeniasis by screening stool samples from 653 randomly chosen subjects, for coproantigens. The costs incurred in the project were used to estimate the cost per case screened and treated. A one-way sensitivity analysis was carried out for varying rates of taeniasis, different screening strategies and mass therapy. Further sensitivity analysis was carried out with different manpower and test costs. The rate of taeniasis as detected by ELISA for coproantigen was 3 per 1000 (2 of 653 samples). Our study showed that mass therapy without screening for taeniasis would be the most economical strategy in terms of cost per case treated if field workers are employed exclusively for either mass therapy or screening. For each strategy, costs per case treated are higher at low prevalence of taeniasis, with a sharp rise below 15%. In places that are endemic for taeniasis and neurocysticercosis, mass therapy or screening for taeniasis should be considered. Screening by stool microscopy is not cost-effective in terms of cost per case of taeniasis treated owing to its low sensitivity. Although the cost per case of taeniasis treated is high at low prevalence of taeniasis for all options, incorporating mass therapy into existing mass drug distribution programmes might prove to be the most cost-effective control strategy. © 2011 Blackwell Publishing Ltd.

  6. Analysis of legal high materials by ultra-performance liquid chromatography with time of flight mass spectrometry as part of a toxicology vigilance system: what are the most popular novel psychoactive substances in the UK?

    PubMed

    Ford, Loretta T; Berg, Jonathan D

    2017-03-01

    Introduction Legal highs also known as novel psychoactive substances mimic the effects of classic drugs of abuse. Challenges to developing screening services for novel psychoactive substances include identifying which novel psychoactive substances are available to target. Using new techniques such as exact mass time of flight can help identify common novel psychoactive substances to target for screening patient samples by routine methods such as tandem mass spectrometry. We demonstrate this strategy working in our own clinical toxicology laboratory after qualitative analysis of 98 suspect materials for novel psychoactive substances by ultra-performance liquid chromatography with time of flight mass spectrometry. Results From July 2014 to July 2015 we received 98 requests to test a range of different suspect materials for novel psychoactive substances including herbs, tobacco, liquids, pills and powders. Overall, 87% of the suspect materials tested positive for novel psychoactive substances, and 15% for controlled drugs. Three common novel psychoactive substances were present in 74% of the suspect materials: methiopropamine, a methamphetamine analogue; ethylphenidate, a cocaine mimic; and the third generation synthetic cannabinoid 5F-AKB-48. For the 55 branded products we tested only 24% of the stated contents matched exactly the compounds we detected. Conclusion Testing suspect materials using ultra-performance liquid chromatography with time of flight mass spectrometry has identified three common novel psychoactive substances in use in the UK, simplifying the development of a relevant novel psychoactive substances screening service to our population. By incorporating this into our routine liquid chromatography tandem mass spectrometry drugs of abuse screen, then offers a clinically relevant novel psychoactive substances service to our users. This strategy ensures our clinical toxicology service continues to remain effective to meet the challenges of the changing drug use in the UK.

  7. Wide-Scope Screening Method for Multiclass Veterinary Drug Residues in Fish, Shrimp, and Eel Using Liquid Chromatography-Quadrupole High-Resolution Mass Spectrometry.

    PubMed

    Turnipseed, Sherri B; Storey, Joseph M; Lohne, Jack J; Andersen, Wendy C; Burger, Robert; Johnson, Aaron S; Madson, Mark R

    2017-08-30

    A screening method for veterinary drug residues in fish, shrimp, and eel using LC with a high-resolution MS instrument has been developed and validated. The method was optimized for over 70 test compounds representing a variety of veterinary drug classes. Tissues were extracted by vortex mixing with acetonitrile acidified with 2% acetic acid and 0.2% p-toluenesulfonic acid. A centrifuged portion of the extract was passed through a novel solid phase extraction cartridge designed to remove interfering matrix components from tissue extracts. The eluent was then evaporated and reconstituted for analysis. Data were collected with a quadrupole-Orbitrap high-resolution mass spectrometer using both nontargeted and targeted acquisition methods. Residues were detected on the basis of the exact mass of the precursor and a product ion along with isotope pattern and retention time matching. Semiquantitative data analysis compared MS 1 signal to a one-point extracted matrix standard at a target testing level. The test compounds were detected and identified in salmon, tilapia, catfish, shrimp, and eel extracts fortified at the target testing levels. Fish dosed with selected analytes and aquaculture samples previously found to contain residues were also analyzed. The screening method can be expanded to monitor for an additional >260 veterinary drugs on the basis of exact mass measurements and retention times.

  8. Business and Breakthrough: Framing (Expanded) Genetic Carrier Screening for the Public.

    PubMed

    Holton, Avery E; Canary, Heather E; Wong, Bob

    2017-09-01

    A growing body of research has given attention to issues surrounding genetic testing, including expanded carrier screening (ECS), an elective medical test that allows planning or expecting parents to consider the potential occurrence of genetic diseases and disorders in their children. These studies have noted the role of the mass media in driving public perceptions about such testing, giving particular attention to ways in which coverage of genetics and genetic testing broadly may drive public attitudes and choices concerning the morality, legality, ethics, and parental well-being involved in genetic technologies. However, few studies have explored how mass media are covering the newer test, ECS. Drawing on health-related framing studies that have shown in varying degrees the impact particular frames such as gain/loss and thematic/episodic can have on the public, this study examines the frame selection employed by online media in its coverage of ECS. This analysis-combined with an analysis of the sources and topics used in such coverage and how they relate to selected frames-helps to clarify how mass media are covering an increasingly important medical test and offers considerations of how such coverage may inform mass media scholarship as well as health-related practices.

  9. Business and Breakthrough: Framing (Expanded) Genetic Carrier Screening for the Public

    PubMed Central

    Holton, Avery E.; Canary, Heather E.; Wong, Bob

    2018-01-01

    A growing body of research has given attention to issues surrounding genetic testing, including expanded carrier screening (ECS), an elective medical test that allows planning or expecting parents to consider the potential occurrence of genetic diseases and disorders in their children. These studies have noted the role of the mass media in driving public perceptions about such testing, giving particular attention to ways in which coverage of genetics and genetic testing broadly may drive public attitudes and choices concerning the morality, legality, ethics, and parental well-being involved in genetic technologies. However, few studies have explored how mass media are covering the newer test, ECS. Drawing on health-related framing studies that have shown in varying degrees the impact particular frames such as gain/loss and thematic/episodic can have on the public, this study examines the frame selection employed by online media in its coverage of ECS. This analysis—combined with an analysis of the sources and topics used in such coverage and how they relate to selected frames—helps to clarify how mass media are covering an increasingly important medical test and offers considerations of how such coverage may inform mass media scholarship as well as health-related practices. PMID:27483980

  10. Screening of lysosomal storage disorders: application of the online trapping-and-cleanup liquid chromatography/mass spectrometry method for mucopolysaccharidosis I.

    PubMed

    Ombrone, Daniela; Malvagia, Sabrina; Funghini, Silvia; Giocaliere, Elisa; Della Bona, Maria Luisa; Forni, Giulia; De Luca, Alessio; Villanelli, Fabio; Casetta, Bruno; Guerrini, Renzo; la Marca, Giancarlo

    2013-01-01

    In recent years, new treatments have become available to treat some lysosomal storage disorders (LSDs) and many studies suggest that there is a benefit with starting therapy early. Newborn screening should detect diseases early enough for prompt treatment. Some countries include additional conditions, such as some LSDs, into their newborn screening panels. Mucopolysaccharidosis Type I (MPS I) is an autosomal recessive disorder caused by the deficiency of α-L-iduronidase (IDUA) activity. Currently, enzyme replacement therapy (ERT) or bone marrow transplantation is available and this has raised a growing interest for the development of a newborn screening test. In 2009, we reported a new fast and simplified tandem mass spectrometry-based method for quantifying five enzyme activities on dried blood spots. Here, we describe the inclusion of IDUA activity determination for the simultaneous detection of six lysosomal storage diseases. We have defined reference normal ranges by testing 680 healthy newborns and 240 adults. The assay was checked through three confirmed MPS I patients whose IDUA activity was below the normal range. Reproducibility of the assays has been established by assessing the intra-day and inter-day assay imprecisions. This quick assay has been devised to be implemented in newborn screening by liquid chromatography tandem mass spectrometry.

  11. Obstacles to colorectal screening in general practice: a qualitative study of GPs and patients.

    PubMed

    Aubin-Auger, Isabelle; Mercier, Alain; Lebeau, Jean-Pierre; Baumann, Laurence; Peremans, Lieve; Van Royen, Paul

    2011-12-01

    The faecal occult blood test (FOBT) has proven efficiency at screening populations for an average risk of colorectal cancer. Mortality related to this cancer decreases by 15-18% among adults, 50-74 years old, tested every 2 years. A participation rate of at least 50% is desirable. This rate has not yet been reached in most French regions. To explore the obstacles to mass colorectal screening in France. In 2009, five focus groups were conducted in different areas to explore physicians' obstacles to FOBT screening. The patients' obstacles were assessed in semi-structured interviews. A purposive sampling had been carried out for both GPs and patients. The focus groups were coded using Nvivo 8(®) software by three researchers; the interviews manually coded by two researchers. GPs reported insufficient training and some doubted the relevance of screening. They expressed concern of having insufficient time for the test during a consultation, as well as practical and administrative obstacles. Some GPs experienced difficulty persuading patients who had no signs of colorectal disease. Obstacles for patients were mainly difficulties in doing screening themselves and a perception of health care that didn't match with screening. Information and organization were also important points to improve. The screening process was considered complex both by GPs and by patients. Numerous obstacles to colorectal screening, from both the physicians' and the patients' perspectives, were found. The major goal to improve mass screening may be to increase awareness and understanding of both physicians and patients regarding this process.

  12. The inclusion of ADA-SCID in expanded newborn screening by tandem mass spectrometry.

    PubMed

    la Marca, Giancarlo; Giocaliere, Elisa; Malvagia, Sabrina; Funghini, Silvia; Ombrone, Daniela; Della Bona, Maria Luisa; Canessa, Clementina; Lippi, Francesca; Romano, Francesca; Guerrini, Renzo; Resti, Massimo; Azzari, Chiara

    2014-01-01

    Severe combined immunodeficiency due to adenosine-deaminase defect (ADA-SCID) is usually deadly in childhood because of severe recurrent infections. When clinical diagnosis is done, permanent damages due to infections or metabolite accumulation are often present. Gene therapy, bone marrow transplantation or enzyme replacement therapy may be effective if started early. The aim of this study was to set-up a robust method suitable for screening with a minimized preparation process and with inexpensive running costs, for diagnosing ADA-SCID by tandem mass spectrometry. ADA-SCID satisfies all the criteria for inclusion in a newborn screening program. We describe a protocol revised to incorporate adenosine and 2-deoxyadenosine testing into an expanded newborn screening program. We assessed the effectiveness of this approach testing dried blood spots from 4 genetically confirmed early-onset and 5 delayed-onset ADA-SCID patients. Reference values were established on 50,000 healthy newborns (deoxyadenosine <0.09μmol/L, adenosine <1.61μmol/L). We also developed a second tier test to distinguish true positives from false positives and improve the positive predictive value of an initial abnormal result. In the first 18 months, the pilot project has identified a newborn with a genetically confirmed defect in adenosine deaminase (ADA) gene. The results show that the method having great simplicity, low cost and low process preparations can be fully applicable to a mass screening program. Copyright © 2013 Elsevier B.V. All rights reserved.

  13. Evaluation of control measures for bovine viral diarrhea implemented in Nemuro District, Hokkaido, Japan, using a scenario tree model

    PubMed Central

    ISODA, Norikazu; ASANO, Akihiro; ICHIJO, Michiru; WAKAMORI, Shiho; OHNO, Hiroshi; SATO, Kazuhiko; OKAMOTO, Hirokazu; NAKAO, Shigeru; KATO, Hajime; SAITO, Kazuma; ITO, Naoki; USUI, Akira; TAKAYAMA, Hiroaki; SAKODA, Yoshihiro

    2017-01-01

    A scenario tree model was developed to propose efficient bovine viral diarrhea (BVD) control measures. The model used field data in eastern Hokkaido where the risk of BVDV infection in cattle has been reduced by an eradication program including mass vaccination, individual tests prior to communal pasture grazing, herd screening tests using bulk milk, and outbreak investigations of newly infected herds. These four activities were then used as hypothesized control measures in the simulation. In each simulation, the numbers of cattle infected persistently and transiently with BVDV detected by clinical manifestations and diagnosis tests and of missed by all of the diagnosis tests were calculated, and the numbers were used as indicators to be compared for the efficacy of the control measures. The model outputs indicated that the adoption of mass vaccination decreased the number of missed BVD cattle, although it did not increase the number of detected BVD cattle. Under implementation of mass vaccination, the efficacy of individual tests on selected 20% of the young and adult cattle was equal to that of the herd screening test performed in all the herds. When the virus prevalence or the number of sensitive animals becomes low, the efficacy of herd screening test was superior to one of individual tests. Considering the model outputs together, the scenario tree model developed in the present study was useful to compare the efficacy of the control measures for BVD. PMID:28539533

  14. Evaluation of control measures for bovine viral diarrhea implemented in Nemuro District, Hokkaido, Japan, using a scenario tree model.

    PubMed

    Isoda, Norikazu; Asano, Akihiro; Ichijo, Michiru; Wakamori, Shiho; Ohno, Hiroshi; Sato, Kazuhiko; Okamoto, Hirokazu; Nakao, Shigeru; Kato, Hajime; Saito, Kazuma; Ito, Naoki; Usui, Akira; Takayama, Hiroaki; Sakoda, Yoshihiro

    2017-07-07

    A scenario tree model was developed to propose efficient bovine viral diarrhea (BVD) control measures. The model used field data in eastern Hokkaido where the risk of BVDV infection in cattle has been reduced by an eradication program including mass vaccination, individual tests prior to communal pasture grazing, herd screening tests using bulk milk, and outbreak investigations of newly infected herds. These four activities were then used as hypothesized control measures in the simulation. In each simulation, the numbers of cattle infected persistently and transiently with BVDV detected by clinical manifestations and diagnosis tests and of missed by all of the diagnosis tests were calculated, and the numbers were used as indicators to be compared for the efficacy of the control measures. The model outputs indicated that the adoption of mass vaccination decreased the number of missed BVD cattle, although it did not increase the number of detected BVD cattle. Under implementation of mass vaccination, the efficacy of individual tests on selected 20% of the young and adult cattle was equal to that of the herd screening test performed in all the herds. When the virus prevalence or the number of sensitive animals becomes low, the efficacy of herd screening test was superior to one of individual tests. Considering the model outputs together, the scenario tree model developed in the present study was useful to compare the efficacy of the control measures for BVD.

  15. Proceedings of the drug testing laboratory managers symposium, 28 January--1 February 1974. Final report

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Noe, E.R.; Romanchick, W.A.; Ainsworth, C.A. III

    1975-06-01

    This report deals with broad concepts of managing mass screening programs for drugs of abuse; e.g., morphine, barbiturate, amphetamine, cocaine, and methaqualone. The interactions of the screening process and of the rehabilitation program were covered. Psychotherapy and group therapy are both utilized in rehabilitation programs. The semiautomated radioimmunoassay (RIA) screening procedures are both sensitive and specific at nanogram quantities. Future evaluations of a wafer disk transferral system and of a latex test for morphine are presented. The unique quality control system employed by military drug abuse testing laboratories is discussed. (Author) (GRA)

  16. Capillary device refilling. [liquid rocket propellant tank tests

    NASA Technical Reports Server (NTRS)

    Blatt, M. H.; Merino, F.; Symons, E. P.

    1980-01-01

    An analytical and experimental study was conducted dealing with refilling start baskets (capillary devices) with settled fluid. A computer program was written to include dynamic pressure, screen wicking, multiple-screen barriers, standpipe screens, variable vehicle mass for computing vehicle acceleration, and calculation of tank outflow rate and vapor pullthrough height. An experimental apparatus was fabricated and tested to provide data for correlation with the analytical model; the test program was conducted in normal gravity using a scale-model capillary device and ethanol as the test fluid. The test data correlated with the analytical model; the model is a versatile and apparently accurate tool for predicting start basket refilling under actual mission conditions.

  17. Improved design of electrophoretic equipment for rapid sickle-cell-anemia screening

    NASA Technical Reports Server (NTRS)

    Reddick, J. M.; Hirsch, I.

    1974-01-01

    Effective mass screening may be accomplished by modifying existing electrophoretic equipment in conjunction with multisample applicator used with cellulose-acetate-matrix test paper. Using this method, approximately 20 to 25 samples can undergo electrophoresis in 5 to 6 minutes.

  18. Evaluation of the fluorescent gonococcal test-heated.

    PubMed Central

    Gaafar, H A

    1976-01-01

    In a 1-year evaluation of the indirect fluorescent antibody test for gonorrhea, 16,127 specimens from low-and high-risk groups were examined, and the results were compared with culture, history of exposure to a known patient, and clinical signs and symptoms. The results confirmed the usefulness of the indirect fluorescent antibody test for gonorrhea as a screening procedure, especially for women in the low-risk group. The test is more economic and probably more sensitive than culture for mass screening of asymptomatic women. PMID:791965

  19. Additional mailing phase for FIT after a medical offer phase: The best way to improve compliance with colorectal cancer screening in France.

    PubMed

    Piette, Christine; Durand, Gérard; Bretagne, Jean-François; Faivre, Jean

    2017-03-01

    Compliance with colorectal cancer screening is critical to its effectiveness. The organisation of the mass screening programme in France has recently been modified with no evaluation of the consequences. To evaluate the impact of the way the screening test is delivered on compliance. During the first six months of the screening campaign (Ille-Vilaine, Brittany), general practitioners were asked to propose a faecal immunochemical test (FIT), OC-Sensor, to individuals at average risk for colorectal cancer (n=152,097). A subset of non-participants in the medical phase (n=13,071) was randomly chosen to receive a reminder that included the screening test or a simple postal reminder without the screening test. Compliance was 31% if the screening test was proposed during a medical consultation. In non-participants during the medical phase, it was 45% in those receiving both a reminder and the screening test and 28% amongst those receiving a simple reminder. An estimated overall participation rate of 54% can be expected if non-participants in the medical phase are sent a reminder together with the screening test. In France, a compliance rate above the minimum uptake rate of 45% recommended by European Union experts can be achieved if the FIT is mailed to non-participants after the medical free-offer phase. Copyright © 2016. Published by Elsevier Ltd.

  20. PROTEOMICS IN ECOTOXICOLOGY: PROTEIN EXPRESSION PROFILING TO SCREEN CHEMICALS FOR ENDOCRINE ACTIVITY

    EPA Science Inventory

    Abstract for poster.

    Current endocrine testing methods are animal intensive and lack the throughput necessary to screen large numbers of environmental chemicals for adverse effects. In this study, Matrix Assisted Laser Desorption/Ionization Time-of-Flight Mass Spectrometry...

  1. Detection and identification of 700 drugs by multi-target screening with a 3200 Q TRAP LC-MS/MS system and library searching.

    PubMed

    Dresen, S; Ferreirós, N; Gnann, H; Zimmermann, R; Weinmann, W

    2010-04-01

    The multi-target screening method described in this work allows the simultaneous detection and identification of 700 drugs and metabolites in biological fluids using a hybrid triple-quadrupole linear ion trap mass spectrometer in a single analytical run. After standardization of the method, the retention times of 700 compounds were determined and transitions for each compound were selected by a "scheduled" survey MRM scan, followed by an information-dependent acquisition using the sensitive enhanced product ion scan of a Q TRAP hybrid instrument. The identification of the compounds in the samples analyzed was accomplished by searching the tandem mass spectrometry (MS/MS) spectra against the library we developed, which contains electrospray ionization-MS/MS spectra of over 1,250 compounds. The multi-target screening method together with the library was included in a software program for routine screening and quantitation to achieve automated acquisition and library searching. With the help of this software application, the time for evaluation and interpretation of the results could be drastically reduced. This new multi-target screening method has been successfully applied for the analysis of postmortem and traffic offense samples as well as proficiency testing, and complements screening with immunoassays, gas chromatography-mass spectrometry, and liquid chromatography-diode-array detection. Other possible applications are analysis in clinical toxicology (for intoxication cases), in psychiatry (antidepressants and other psychoactive drugs), and in forensic toxicology (drugs and driving, workplace drug testing, oral fluid analysis, drug-facilitated sexual assault).

  2. Pathology consultation on urine compliance testing and drug abuse screening.

    PubMed

    Ward, Michael B; Hackenmueller, Sarah A; Strathmann, Frederick G

    2014-11-01

    Compliance testing in pain management requires a distinct approach compared with classic clinical toxicology testing. Differences in the patient populations and clinical expectations require modifications to established reporting cutoffs, assay performance expectations, and critical review of how best to apply the available testing methods. Although other approaches to testing are emerging, immunoassay screening followed by mass spectrometry confirmation remains the most common testing workflow for pain management compliance and drug abuse testing. A case-based approach was used to illustrate the complexities inherent to and uniqueness of pain management compliance testing for both clinicians and laboratories. A basic understanding of the inherent strengths and weaknesses of immunoassays and mass spectrometry provides the clinician a better understanding of how best to approach pain management compliance testing. Pain management compliance testing is a textbook example of an emerging field requiring open communication between physician and performing laboratory to fully optimize patient care. Copyright© by the American Society for Clinical Pathology.

  3. Budget impact analysis of chronic kidney disease mass screening test in Japan.

    PubMed

    Kondo, Masahide; Yamagata, Kunihiro; Hoshi, Shu-Ling; Saito, Chie; Asahi, Koichi; Moriyama, Toshiki; Tsuruya, Kazuhiko; Konta, Tsuneo; Fujimoto, Shouichi; Narita, Ichiei; Kimura, Kenjiro; Iseki, Kunitoshi; Watanabe, Tsuyoshi

    2014-12-01

    Our recently published cost-effectiveness study on chronic kidney disease mass screening test in Japan evaluated the use of dipstick test, serum creatinine (Cr) assay or both in specific health checkup (SHC). Mandating the use of serum Cr assay additionally, or the continuation of current policy mandating dipstick test only was found cost-effective. This study aims to examine the affordability of previously suggested reforms. Budget impact analysis was conducted assuming the economic model would be good for 15 years and applying a population projection. Costs expended by social insurers without discounting were counted as budgets. Annual budget impacts of mass screening compared with do-nothing scenario were calculated as ¥79-¥-1,067 million for dipstick test only, ¥2,505-¥9,235 million for serum Cr assay only and ¥2,517-¥9,251 million for the use of both during a 15-year period. Annual budget impacts associated with the reforms were calculated as ¥975-¥4,129 million for mandating serum Cr assay in addition to the currently used mandatory dipstick test, and ¥963-¥4,113 million for mandating serum Cr assay only and abandoning dipstick test. Estimated values associated with the reform from ¥963-¥4,129 million per year over 15 years are considerable amounts of money under limited resources. The most impressive finding of this study is the decreasing additional expenditures in dipstick test only scenario. This suggests that current policy which mandates dipstick test only would contain medical care expenditure.

  4. Direct mass spectrometric screening of antibiotics from bacterial surfaces using liquid extraction surface analysis.

    PubMed

    Kai, Marco; González, Ignacio; Genilloud, Olga; Singh, Sheo B; Svatoš, Aleš

    2012-10-30

    There is a need to find new antibiotic agents to fight resistant pathogenic bacteria. To search successfully for novel antibiotics from bacteria cultivated under diverse conditions, we need a fast and cost-effective screening method. A combination of Liquid Extraction Surface Analysis (LESA), automated chip-based nanoelectrospray ionization, and high-resolution mass or tandem mass spectrometry using an Orbitrap XL was tested as the screening platform. Actinobacteria, known to produce well-recognized thiazolyl peptide antibiotics, were cultivated on a plate of solid medium and the antibiotics were extracted by organic solvent mixtures from the surface of colonies grown on the plate and analyzed using mass spectrometry (MS). LESA combined with high-resolution MS is a powerful tool with which to extract and detect thiazolyl peptide antibiotics from different Actinobacteria. Known antibiotics were correctly detected with high mass accuracy (<4 ppm) and structurally characterized using tandem mass spectra. Our method is the first step toward the development of a novel high-throughput extraction and identification tool for antibiotics in particular and natural products in general. The method described in this paper is suitable for (1) screening the natural products produced by bacterial colonies on cultivation plates within the first 2 min following extraction and (2) detecting antibiotics at high mass accuracy; the cost is around 2 Euro per sample. Copyright © 2012 John Wiley & Sons, Ltd.

  5. "Chair Stand Test" as Simple Tool for Sarcopenia Screening in Elderly Women.

    PubMed

    Pinheiro, P A; Carneiro, J A O; Coqueiro, R S; Pereira, R; Fernandes, M H

    2016-01-01

    To investigate the association between sarcopenia and "chair stand test" performance, and evaluate this test as a screening tool for sarcopenia in community-dwelling elderly women. Cross-sectional Survey. 173 female individuals, aged ≥ 60 years and living in the urban area of the municipality of Lafaiete Coutinho, Bahia's inland, Brazil. The association between sarcopenia (defined by muscle mass, strength and/or performance loss) and performance in the "chair stand test" was tested by binary logistic regression technique. The ROC curve parameters were used to evaluate the diagnostic power of the test in sarcopenia screening. The significance level was set at 5 %. The model showed that the time spent for the "chair stand test" was positively associated (OR = 1.08; 95% CI = 1.01 - 1.16, p = 0.024) to sarcopenia, indicating that, for each 1 second increment in the test performance, the sarcopenia's probability increased by 8% in elderly women. The cut-off point that showed the best balance between sensitivity and specificity was 13 seconds. The performance of "chair stand test" showed predictive ability for sarcopenia, being an effective and simple screening tool for sarcopenia in elderly women. This test could be used for screening sarcopenic elderly women, allowing early interventions.

  6. Equivalence principle implications of modified gravity models

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Hui, Lam; Nicolis, Alberto; Stubbs, Christopher W.

    2009-11-15

    Theories that attempt to explain the observed cosmic acceleration by modifying general relativity all introduce a new scalar degree of freedom that is active on large scales, but is screened on small scales to match experiments. We demonstrate that if such screening occurs via the chameleon mechanism, such as in f(R) theory, it is possible to have order unity violation of the equivalence principle, despite the absence of explicit violation in the microscopic action. Namely, extended objects such as galaxies or constituents thereof do not all fall at the same rate. The chameleon mechanism can screen the scalar charge formore » large objects but not for small ones (large/small is defined by the depth of the gravitational potential and is controlled by the scalar coupling). This leads to order one fluctuations in the ratio of the inertial mass to gravitational mass. We provide derivations in both Einstein and Jordan frames. In Jordan frame, it is no longer true that all objects move on geodesics; only unscreened ones, such as test particles, do. In contrast, if the scalar screening occurs via strong coupling, such as in the Dvali-Gabadadze-Porrati braneworld model, equivalence principle violation occurs at a much reduced level. We propose several observational tests of the chameleon mechanism: 1. small galaxies should accelerate faster than large galaxies, even in environments where dynamical friction is negligible; 2. voids defined by small galaxies would appear larger compared to standard expectations; 3. stars and diffuse gas in small galaxies should have different velocities, even if they are on the same orbits; 4. lensing and dynamical mass estimates should agree for large galaxies but disagree for small ones. We discuss possible pitfalls in some of these tests. The cleanest is the third one where the mass estimate from HI rotational velocity could exceed that from stars by 30% or more. To avoid blanket screening of all objects, the most promising place to look is in voids.« less

  7. Physiological Capacities: Estimating an Athlete's Potential.

    ERIC Educational Resources Information Center

    Lemon, Peter W. R.

    1982-01-01

    Several simple performance tests are described for assessing an athlete's major energy-producing capabilities. The tests are suitable for mass screening because they are easy to administer, require no sophisticated equipment, and can be done quickly. Information for evaluating test results is included. (PP)

  8. Standardized assessment of infrared thermographic fever screening system performance

    NASA Astrophysics Data System (ADS)

    Ghassemi, Pejhman; Pfefer, Joshua; Casamento, Jon; Wang, Quanzeng

    2017-03-01

    Thermal modalities represent the only currently viable mass fever screening approach for outbreaks of infectious disease pandemics such as Ebola and SARS. Non-contact infrared thermometers (NCITs) and infrared thermographs (IRTs) have been previously used for mass fever screening in transportation hubs such as airports to reduce the spread of disease. While NCITs remain a more popular choice for fever screening in the field and at fixed locations, there has been increasing evidence in the literature that IRTs can provide greater accuracy in estimating core body temperature if appropriate measurement practices are applied - including the use of technically suitable thermographs. Therefore, the purpose of this study was to develop a battery of evaluation test methods for standardized, objective and quantitative assessment of thermograph performance characteristics critical to assessing suitability for clinical use. These factors include stability, drift, uniformity, minimum resolvable temperature difference, and accuracy. Two commercial IRT models were characterized. An external temperature reference source with high temperature accuracy was utilized as part of the screening thermograph. Results showed that both IRTs are relatively accurate and stable (<1% error of reading with stability of +/-0.05°C). Overall, results of this study may facilitate development of standardized consensus test methods to enable consistent and accurate use of IRTs for fever screening.

  9. Newborn screening for citrin deficiency and carnitine uptake defect using second-tier molecular tests.

    PubMed

    Wang, Li-Yun; Chen, Nien-I; Chen, Pin-Wen; Chiang, Shu-Chuan; Hwu, Wuh-Liang; Lee, Ni-Chung; Chien, Yin-Hsiu

    2013-02-10

    Tandem mass spectrometry (MS/MS) analysis is a powerful tool for newborn screening, and many rare inborn errors of metabolism are currently screened using MS/MS. However, the sensitivity of MS/MS screening for several inborn errors, including citrin deficiency (screened by citrulline level) and carnitine uptake defect (CUD, screened by free carnitine level), is not satisfactory. This study was conducted to determine whether a second-tier molecular test could improve the sensitivity of citrin deficiency and CUD detection without increasing the false-positive rate. Three mutations in the SLC25A13 gene (for citrin deficiency) and one mutation in the SLC22A5 gene (for CUD) were analyzed in newborns who demonstrated an inconclusive primary screening result (with levels between the screening and diagnostic cutoffs). The results revealed that 314 of 46 699 newborns received a second-tier test for citrin deficiency, and two patients were identified; 206 of 30 237 newborns received a second-tier testing for CUD, and one patient was identified. No patients were identified using the diagnostic cutoffs. Although the incidences for citrin deficiency (1:23 350) and CUD (1:30 000) detected by screening are still lower than the incidences calculated from the mutation carrier rates, the second-tier molecular test increases the sensitivity of newborn screening for citrin deficiency and CUD without increasing the false-positive rate. Utilizing a molecular second-tier test for citrin deficiency and carnitine transporter deficiency is feasible.

  10. [Variations in the diagnostic confirmation process between breast cancer mass screening units].

    PubMed

    Natal, Carmen; Fernández-Somoano, Ana; Torá-Rocamora, Isabel; Tardón, Adonina; Castells, Xavier

    2016-01-01

    To analyse variations in the diagnostic confirmation process between screening units, variations in the outcome of each episode and the relationship between the use of the different diagnostic confirmation tests and the lesion detection rate. Observational study of variability of the standardised use of diagnostic and lesion detection tests in 34 breast cancer mass screening units participating in early-detection programmes in three Spanish regions from 2002-2011. The diagnostic test variation ratio in percentiles 25-75 ranged from 1.68 (further appointments) to 3.39 (fine-needle aspiration). The variation ratio in detection rates of benign lesions, ductal carcinoma in situ and invasive cancer were 2.79, 1.99 and 1.36, respectively. A positive relationship between rates of testing and detection rates was found with fine-needle aspiration-benign lesions (R(2): 0.53), fine-needle aspiration-invasive carcinoma (R(2): 0 28), core biopsy-benign lesions (R(2): 0.64), core biopsy-ductal carcinoma in situ (R(2): 0.61) and core biopsy-invasive carcinoma (R(2): 0.48). Variation in the use of invasive tests between the breast cancer screening units participating in early-detection programmes was found to be significantly higher than variations in lesion detection. Units which conducted more fine-needle aspiration tests had higher benign lesion detection rates, while units that conducted more core biopsies detected more benign lesions and cancer. Copyright © 2016 SESPAS. Published by Elsevier Espana. All rights reserved.

  11. Urine testing for designer steroids by liquid chromatography with androgen bioassay detection and electrospray quadrupole time-of-flight mass spectrometry identification.

    PubMed

    Nielen, Michel W F; Bovee, Toine F H; van Engelen, Marcel C; Rutgers, Paula; Hamers, Astrid R M; van Rhijn, J Hans A; Hoogenboom, L Ron A P

    2006-01-15

    New anabolic steroids show up occasionally in sports doping and in veterinary control. The discovery of these designer steroids is facilitated by findings of illicit preparations, thus allowing bioactivity testing, structure elucidation using NMR and mass spectrometry, and final incorporation in urine testing. However, as long as these preparations remain undiscovered, new designer steroids are not screened for in routine sports doping or veterinary control urine tests since the established GC/MS and LC/MS/MS methods are set up for the monitoring of a few selected ions or MS/MS transitions of known substances only. In this study, the feasibility of androgen bioactivity testing and mass spectrometric identification is being investigated for trace analysis of designer steroids in urine. Following enzymatic deconjugation and a generic solid-phase extraction, the samples are analyzed by gradient LC with effluent splitting toward two identical 96-well fraction collectors. One well plate is used for androgen bioactivity detection using a novel robust yeast reporter gene bioassay yielding a biogram featuring a 20-s time resolution. The bioactive wells direct the identification efforts to the corresponding well numbers in the duplicate plate. These are subjected to high-resolution LC using a short column packed with 1.7-microm C18 material and coupled with electrospray quadrupole time-of-flight mass spectrometry (LC/QTOFMS) with accurate mass measurement. Element compositions are calculated and used to interrogate electronic substance databases. The feasibility of this approach for doping control is demonstrated via the screening of human urine samples spiked with the designer anabolic steroid tetrahydrogestrinone. Application of the proposed methodology, complementary to the established targeted urine screening for known anabolics, will increase the chance of finding unknown emerging designer steroids, rather then being solely dependent on findings of the illicit preparations themselves.

  12. Expanded newborn screening: social and ethical issues.

    PubMed

    Dhondt, Jean-Louis

    2010-10-01

    Newborn screening and genetic testing have expanded rapidly in the last decade with the advent of multiplex (e.g., tandem mass spectrometry) and/or DNA technologies. However, screening panels include a large number of disorders, which may not meet all of the traditional screening criteria, established in late 1960s, and used for years to justify screening programs. After a period of expansion driven by technological advances, many reports have reconsidered the justification of expanded programs. Many factors have contributed to test-panel discrepancies between countries. The test-panel review methodology, the way health benefits are weighed against harms, and the socioeconomic-political environment all play a role. Expansion of screening also requires reconsideration of the infrastructure (ideally, in the context of national plans for rare diseases) to support testing, counselling, education, treatment, and follow-up. Consequently, economic aspects cannot be ignored and can be a limitation for expansion. New ethical questions have emerged: risks of discrimination or stigmatization, respect of the autonomy of persons to make decisions, parental anxiety resulting from a false positive test (especially when reporting to parents screening results for untreatable conditions identified as by-products of screening), etc. For disorders where there is not yet confirmation of benefit, it may be prudent to recommend pilot screening and to have a mechanism that can be used to adapt or even to stop a program.

  13. Environmental screening of dark matter haloes in f(R) gravity

    NASA Astrophysics Data System (ADS)

    Shi, Difu; Li, Baojiu; Han, Jiaxin

    2017-07-01

    In certain theories of modified gravity, Solar system constraints on deviations from general relativity (GR) are satisfied by virtue of a so-called screening mechanism, which enables the theory to revert to GR in regions where the matter density is high or the gravitational potential is deep. In the case of chameleon theories, the screening has two contributions - self-screening, which is due to the mass of an object itself, and environmental screening, which is caused by the surrounding matter - which are often entangled, with the second contribution being more crucial for less massive objects. A quantitative understanding of the effect of the environment on the screening can prove critical in observational tests of such theories using systems such as the Local Group and dwarf galaxies, for which the environment may be inferred in various ways. We use the high-resolution liminality simulation of Shi et al. to test the fidelity of different definitions of environment. We find that, although the different ways to define environment in practice do not agree with one another perfectly, they can provide useful guidance, and cross checks about how well a dark matter halo is screened. In addition, the screening of subhaloes in dark matter haloes is primarily determined by the environment, with the subhalo mass playing a minor role, which means that lower resolution simulations where subhaloes are not well resolved can still be useful for understanding the modification of gravity inside subhaloes.

  14. Early Pregnancy Diabetes Screening and Diagnosis: Prevalence, Rates of Abnormal Test Results, and Associated Factors.

    PubMed

    Mission, John F; Catov, Janet; Deihl, Tiffany E; Feghali, Maisa; Scifres, Christina

    2017-11-01

    To evaluate the prevalence of early diabetes screening in pregnancy, rates of abnormal diabetes test results before 24 weeks of gestation, and factors associated with early diabetes screening. This was a retrospective cohort study of all singleton deliveries from 2012 to 2014 among diverse clinical practices at a large academic medical center. We assessed rates of early (less than 24 weeks of gestation) and routine (at or beyond 24 weeks of gestation) diabetes screening, with abnormal test results defined using the Carpenter-Coustan criteria, a 50-g glucose challenge test result greater than 200 mg/dL, or a hemoglobin A1C level greater than 6.5%. Univariate and multivariate analyses were used to evaluate clinical and demographic determinants of screening and diagnosis. Overall, 1,420 of 11,331 (12.5%) women underwent early screening. Increasing body mass index (BMI) category, race, public insurance, history of gestational diabetes mellitus, a family history of diabetes, and chronic hypertension were associated with early screening. Early screening rates rose with increasing BMI category, but only 268 of 551 (48.6%) of women with class III obesity underwent early screening. Among those screened early, 2.0% of normal-weight women, 4.0% of overweight women, 4.2% of class I obese women, 3.8% of class II obese women, and 9.0% of class III obese women had abnormal early test results (P<.001). Early diabetes screening is used inconsistently, and many women with risk factors do not undergo early screening. A significant proportion of women with class III obesity will test positive for gestational diabetes mellitus before 24 weeks of gestation, and studies are urgently needed to assess the effect of early diabetes screening and diagnosis on perinatal outcomes in high-risk women.

  15. Newborn screening of metabolic disorders: recent progress and future developments.

    PubMed

    Rinaldo, Piero; Lim, James S; Tortorelli, Silvia; Gavrilov, Dimitar; Matern, Dietrich

    2008-01-01

    Tandem mass spectrometry has been the main driver behind a significant expansion in newborn screening programs. The ability to detect more than 40 conditions by a single test underscores the need to better understand the clinical and laboratory characteristics of the conditions being tested, and the complexity of pattern recognition and differential diagnoses of one or more elevated markers. The panel of conditions recommended by the American College of Medical Genetics, including 20 primary conditions and 22 secondary targets that are detectable by tandem mass spectrometry has been adopted as the standard of care in the vast majority of US states. The evolution of newborn screening is far from being idle as a large number of infectious, genetic, and metabolic conditions are currently under investigation at variable stages of test development and clinical validation. In the US, a formal process with oversight by the Advisory Committee on Heritable Disorders and Genetic Diseases in Newborns and Children has been established for nomination and evidence-based review of new candidate conditions. If approved, these conditions could be added to the uniform panel and consequently pave the way to large scale implementation.

  16. Lead Poison Detection

    NASA Technical Reports Server (NTRS)

    1976-01-01

    With NASA contracts, Whittaker Corporations Space Science division has developed an electro-optical instrument to mass screen for lead poisoning. Device is portable and detects protoporphyrin in whole blood. Free corpuscular porphyrins occur as an early effect of lead ingestion. Also detects lead in urine used to confirm blood tests. Test is inexpensive and can be applied by relatively unskilled personnel. Similar Whittaker fluorometry device called "drug screen" can measure morphine and quinine in urine much faster and cheaper than other methods.

  17. The suitability of matrix assisted laser desorption/ionization time of flight mass spectrometry in a laboratory developed test using cystic fibrosis carrier screening as a model.

    PubMed

    Farkas, Daniel H; Miltgen, Nicholas E; Stoerker, Jay; van den Boom, Dirk; Highsmith, W Edward; Cagasan, Lesley; McCullough, Ron; Mueller, Reinhold; Tang, Lin; Tynan, John; Tate, Courtney; Bombard, Allan

    2010-09-01

    We designed a laboratory developed test (LDT) by using an open platform for mutation/polymorphism detection. Using a 108-member (mutation plus variant) cystic fibrosis carrier screening panel as a model, we completed the last phase of LDT validation by using matrix-assisted laser desorption/ionization time of flight mass spectrometry. Panel customization was accomplished via specific amplification primer and extension probe design. Amplified genomic DNA was subjected to allele specific, single base extension endpoint analysis by mass spectrometry for inspection of the cystic fibrosis transmembrane regulator gene (NM_000492.3). The panel of mutations and variants was tested against 386 blinded samples supplied by "authority" laboratories highly experienced in cystic fibrosis transmembrane regulator genotyping; >98% concordance was observed. All discrepant and discordant results were resolved satisfactorily. Taken together, these results describe the concluding portion of the LDT validation process and the use of mass spectrometry to detect a large number of complex reactions within a single run as well as its suitability as a platform appropriate for interrogation of scores to hundreds of targets.

  18. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Gratia, Pierre; Hu, Wayne; Enrico Fermi Institute and Kavli Institute for Cosmological Physics, University of Chicago,South Ellis Avenue, Chicago, IL 60637

    Attempts to modify gravity in the infrared typically require a screening mechanism to ensure consistency with local tests of gravity. These screening mechanisms fit into three broad classes; we investigate theories which are capable of exhibiting more than one type of screening. Specifically, we focus on a simple model which exhibits both Vainshtein and kinetic screening. We point out that due to the two characteristic length scales in the problem, the type of screening that dominates depends on the mass of the sourcing object, allowing for different phenomenology at different scales. We consider embedding this double screening phenomenology in amore » broader cosmological scenario and show that the simplest examples that exhibit double screening are radiatively stable.« less

  19. Rapid assessment of Schistosoma mansoni: the validity, applicability and cost-effectiveness of the Lot Quality Assurance Sampling method in Uganda

    PubMed Central

    Brooker, Simon; Kabatereine, Narcis B.; Myatt, Mark; Stothard, J. Russell; Fenwick, Alan

    2007-01-01

    Summary Rapid and accurate identification of communities at highest risk of morbidity from schistosomiasis is key for sustainable control. Although school questionnaires can effectively and inexpensively identify communities with a high prevalence of Schistosoma haematobium, parasitological screening remains the preferred option for S. mansoni. To help reduce screening costs, we investigated the validity of Lot Quality Assurance Sampling (LQAS) in classifying schools according categories of S. mansoni prevalence in Uganda, and explored its applicability and cost-effectiveness. First, we evaluated several sampling plans using computer simulation and then field tested one sampling plan in 34 schools in Uganda. Finally, cost-effectiveness of different screening and control strategies (including mass treatment without prior screening) was determined, and sensitivity analysis undertaken to assess the effect of infection levels and treatment costs. In identifying schools with prevalence ≥50%, computer simulations showed that LQAS had high levels of sensitivity and specificity (>90%) at sample sizes <20. The method also provides an ability to classify communities into three prevalence categories. Field testing showed that LQAS where 15 children were sampled had excellent diagnostic performance (sensitivity: 100%, specificity: 96.4%, positive predictive value: 85.7% and negative predictive value: 92.3%). Screening using LQAS was more cost-effective than mass treating all schools (US$ 218 vs. US$ 482 / high prevalence school treated). Threshold analysis indicated that parasitological screening and mass treatment would become equivalent for settings where prevalence exceeds 50% in 75% of schools and for treatment costs of US$ 0.19 per schoolchild. We conclude that, in Uganda, LQAS provides a rapid, valid, and cost-effective method for guiding decision makers in allocating finite resources for the control of schistosomiasis. PMID:15960703

  20. Rapid assessment of Schistosoma mansoni: the validity, applicability and cost-effectiveness of the Lot Quality Assurance Sampling method in Uganda.

    PubMed

    Brooker, Simon; Kabatereine, Narcis B; Myatt, Mark; Russell Stothard, J; Fenwick, Alan

    2005-07-01

    Rapid and accurate identification of communities at highest risk of morbidity from schistosomiasis is key for sustainable control. Although school questionnaires can effectively and inexpensively identify communities with a high prevalence of Schistosoma haematobium, parasitological screening remains the preferred option for S. mansoni. To help reduce screening costs, we investigated the validity of Lot Quality Assurance Sampling (LQAS) in classifying schools according to categories of S. mansoni prevalence in Uganda, and explored its applicability and cost-effectiveness. First, we evaluated several sampling plans using computer simulation and then field tested one sampling plan in 34 schools in Uganda. Finally, cost-effectiveness of different screening and control strategies (including mass treatment without prior screening) was determined, and sensitivity analysis undertaken to assess the effect of infection levels and treatment costs. In identifying schools with prevalences > or =50%, computer simulations showed that LQAS had high levels of sensitivity and specificity (>90%) at sample sizes <20. The method also provides an ability to classify communities into three prevalence categories. Field testing showed that LQAS where 15 children were sampled had excellent diagnostic performance (sensitivity: 100%, specificity: 96.4%, positive predictive value: 85.7% and negative predictive value: 92.3%). Screening using LQAS was more cost-effective than mass treating all schools (US$218 vs. US$482/high prevalence school treated). Threshold analysis indicated that parasitological screening and mass treatment would become equivalent for settings where prevalence > or =50% in 75% of schools and for treatment costs of US$0.19 per schoolchild. We conclude that, in Uganda, LQAS provides a rapid, valid and cost-effective method for guiding decision makers in allocating finite resources for the control of schistosomiasis.

  1. Long term effects of community-based STI screening and mass media HIV prevention messages on sexual risk behaviors of African American adolescents.

    PubMed

    Sznitman, Sharon; Stanton, Bonita F; Vanable, Peter A; Carey, Michael P; Valois, Robert F; Brown, Larry K; DiClemente, Ralph; Hennessy, Michael; Salazar, Laura F; Romer, Daniel

    2011-11-01

    We examined the long-term effects of two interventions designed to reduce sexual risk behavior among African American adolescents. African American adolescents (N = 1383, ages 14-17) were recruited from community-based organizations over a period of 16 months in two northeastern and two southeastern mid-sized U.S. cities with high rates of sexually transmitted infection (STI). Participants were screened for three STIs (gonorrhea, chlamydia, and trichomoniasis) and completed an audio computer-assisted attitude, intention, and behavior self-interview. Youth who tested positive for an STI (8.3%) received treatment and risk reduction counseling. In addition, television and radio HIV-prevention messages were delivered during the recruitment period and 18 months of follow-up in one randomly selected city in each region. Analyses determined effects of the media program for those receiving a positive versus negative STI test result on number of sexual partners and occurrence of unprotected sex. Adolescents who tested STI-positive reduced their number of vaginal sex partners and the probability of unprotected sex over the first 6 months. However, in the absence of the mass media program, adolescents returned to their previously high levels of sexual risk behavior after 6 months. Adolescents who tested STI-positive and received the mass media program showed more stable reductions in unprotected sex. Community-based STI treatment and counseling can achieve significant, but short-lived reductions in sexual risk behavior among STI-positive youth. A culturally sensitive mass media program has the potential to achieve more stable reductions in sexual risk behavior and can help to optimize the effects of community-based STI screening.

  2. Utility of ELISA screening for the monitoring of abstinence from illegal and legal drugs in hair and urine.

    PubMed

    Agius, Ronald; Nadulski, Thomas

    2014-06-01

    Amphetamines, cannabinoids, cocaine, opiates, methadone, and benzodiazepines in authentic hair samples with drug concentrations around the medical and psychological assessment (MPA) guidelines cut-offs were screened by LUCIO-direct ELISA kits. Following confirmation of all positive and a significant number of negatively screened samples with gas chromatography-mass spectrometry (GC-MS) or liquid chromatography-tandem mass spectrometry (LC-MS/MS) methods accredited for forensic purposes. Receiver operating characteristics (ROC) were plotted and the area under the curve (AUC) and overall misclassification rate (OMR) were calculated and compared to those obtained for the same drug classes in urine. While fulfilling the validation criteria of the German forensic guidelines, for almost all screening tests in hair and urine the AUC were greater than 0.8, indicating good to excellent performance. Moreover the AUC calculated for the detection of drugs in hair did not differ significantly to the AUC calculated for the detection of the same drug classes in urine, thus showing a comparable screening performance to the well accepted, previously published application of the same ELISAs for the detection of drugs at unconventionally low cut-offs in urine. For the first time, the validation of the immunoassay tests for the complete 6-drug panel MPA profile in hair and urine using a large population of authentic hair and urine samples with drug concentrations around MPA cut-offs, lower than conventional clinical or workplace drug testing guidelines cut-offs as well as those suggested by the Society of hair testing (SoHT) is presented. Copyright © 2014 John Wiley & Sons, Ltd.

  3. Mammographic findings of women recalled for diagnostic work-up in digital versus screen-film mammography in a population-based screening program.

    PubMed

    Lipasti, Seppo; Anttila, Ahti; Pamilo, Martti

    2010-06-01

    Limited information is available concerning differences in the radiological findings of women recalled for diagnostic work-up in digital mammography (DM) versus screen-film mammography (SFM) screening. To compare the radiological findings, their positive predictive values (PPVs) for cancer and other process indicators of DM screening performed by computed radiography (CR) technology and SFM screening in a population-based program. The material consisted of women, 50-59 years of age, who were invited for screening: 30 153 women with DM in 2007-2008 and 32 939 women with SFM in 1999-2000. The attendance rate was 77.7% (23 440) in the DM arm and 83.8% (27 593) in the SFM arm. In the DM arm, 1.71% of those screened (401) and in the SFM arm 1.59% (438) were recalled for further work-up. The images resulting in the recall were classified as: 1) tumor-like mass, 2) parenchymal distortion/asymmetry, 3) calcifications, and 4) combination of mass and calcifications. The distributions of the various radiological findings and their PPVs for cancer were compared in both study groups. The recall rates, cancer detection rates, test specificities, and PPVs of the DM and SFM groups were also compared. Women were recalled for diagnostic work-up most often due to tumor-like mass. It was more common in SFM (1.08% per woman screened) than in DM (0.93%). The second most common finding was parenchymal distortion and asymmetry, more often in DM (0.58%) than in SFM (0.37%). Calcifications were the third most common finding. DM exposed calcifications more often (0.49%) than SFM (0.26%). The PPVs for cancer of the recalls were higher in DM than in SFM in all subgroups of radiological findings. The test specificities were similar (DM 98.9%, SFM 98.8%). Significantly more cancers were detected by DM (cancer detection rate 0.623% per woman screened, n=146) than by SFM (cancer detection rate 0.406% per woman screened, n=112). The PPVs for cancer of all recalls for diagnostic work-up were significantly higher in DM (36%) than in SFM (26%). In DM women were recalled for diagnostic work-up more often for calcifications, parenchymal distortions, and asymmetries than in SFM. In the case of tumor-like masses, more women were recalled in SFM. DM detected more cancers than SFM, and the PPVs for cancer were higher in DM than in SFM in all subgroups of radiological findings.

  4. Efficacy of communication skills training on colorectal cancer screening by GPs: a cluster randomised controlled trial.

    PubMed

    Aubin-Auger, I; Laouénan, C; Le Bel, J; Mercier, A; Baruch, D; Lebeau, J P; Youssefian, A; Le Trung, T; Peremans, L; Van Royen, P

    2016-01-01

    Colorectal cancer (CRC) mass screening has been implemented in France since 2008. Participation rates remain too low. The objective of this study was to test if the implementation of a training course focused on communication skills among general practitioners (GP) would increase the delivery of gaiac faecal occult blood test and CRC screening participation among the target population of each participating GP. A cluster randomised controlled trial was conducted with GP's practice as a cluster unit. GPs from practices in the control group were asked to continue their usual care. GPs of the intervention group received a 4-h educational training, built with previous qualitative data on CRC screening focusing on doctor-patient communication with a follow-up of 7 months for both groups. The primary outcome measure was the patients' participation rate in the target population for each GP. Seventeen GPs (16 practices) in intervention group and 28 GPs (19 practices) in control group participated. The patients' participation rate in the intervention group were 36.7% vs. 24.5% in the control group (P = 0.03). Doctor-patient communication should be developed and appear to be one of the possible targets of improvement patients adherence and participation rate in the target population for CRC mass screening. © 2015 John Wiley & Sons Ltd.

  5. Value of screening endoscopy in evaluation of esophageal, gastric and colon cancers

    PubMed Central

    Ro, Tae H; Mathew, Michelle A; Misra, Subhasis

    2015-01-01

    Esophageal, gastric, and colorectal cancers are deadly diseases that continue to plague our world today. The value of screening endoscopy in evaluating these types of cancers is a critical area of discussion due to a potential reduction in morbidity and mortality. This article describes how to identify a good screening test and explains what are important criteria in the field of screening endoscopy. Furthermore, the current status and progress of screening endoscopy for esophageal, gastric, and colorectal cancer will be evaluated and discussed. Mass screening programs have not been implemented for esophageal and gastric carcinomas in those with average or low risk populations. However, studies of high-risk populations have found value and a cost-benefit in conducting screening endoscopy. Colorectal cancer, on the other hand, has had mass screening programs in place for many years due to the clear evidence of improved outcomes. As the role of endoscopy as a screening tool has continued to develop, newer technology and techniques have emerged to improve its utility. Many new image enhancement techniques and computer processing programs have shown promise and may have a significant role in the future of endoscopic screening. These developments are paving the way for improving the diagnostic and therapeutic capability of endoscopy in the field of gastroenterology. PMID:26361416

  6. Value of screening endoscopy in evaluation of esophageal, gastric and colon cancers.

    PubMed

    Ro, Tae H; Mathew, Michelle A; Misra, Subhasis

    2015-09-07

    Esophageal, gastric, and colorectal cancers are deadly diseases that continue to plague our world today. The value of screening endoscopy in evaluating these types of cancers is a critical area of discussion due to a potential reduction in morbidity and mortality. This article describes how to identify a good screening test and explains what are important criteria in the field of screening endoscopy. Furthermore, the current status and progress of screening endoscopy for esophageal, gastric, and colorectal cancer will be evaluated and discussed. Mass screening programs have not been implemented for esophageal and gastric carcinomas in those with average or low risk populations. However, studies of high-risk populations have found value and a cost-benefit in conducting screening endoscopy. Colorectal cancer, on the other hand, has had mass screening programs in place for many years due to the clear evidence of improved outcomes. As the role of endoscopy as a screening tool has continued to develop, newer technology and techniques have emerged to improve its utility. Many new image enhancement techniques and computer processing programs have shown promise and may have a significant role in the future of endoscopic screening. These developments are paving the way for improving the diagnostic and therapeutic capability of endoscopy in the field of gastroenterology.

  7. Medical devices; ovarian adnexal mass assessment score test system; labeling; black box restrictions. Final rule.

    PubMed

    2011-12-30

    The Food and Drug Administration (FDA) is amending the regulation classifying ovarian adnexal mass assessment score test systems to restrict these devices so that a prescribed warning statement that addresses a risk identified in the special controls guidance document must be in a black box and must appear in all labeling, advertising, and promotional material. The black box warning mitigates the risk to health associated with off-label use as a screening test, stand-alone diagnostic test, or as a test to determine whether or not to proceed with surgery.

  8. Laser mass spectrometry for DNA sequencing, disease diagnosis, and fingerprinting

    NASA Astrophysics Data System (ADS)

    Chen, C. H. Winston; Taranenko, N. I.; Zhu, Y. F.; Chung, C. N.; Allman, S. L.

    1997-05-01

    Since laser mass spectrometry has the potential for achieving very fast DNA analysis, we recently applied it to DNA sequencing, DNA typing for fingerprinting, and DNA screening for disease diagnosis. Two different approaches for sequencing DNA have been successfully demonstrated. One is to sequence DNA with DNA ladders produced from Sanger's enzymatic method. The other is to do direct sequencing without DNA ladders. The need for quick DNA typing for identification purposes is critical for forensic application. Our preliminary results indicate laser mass spectrometry can possible be used for rapid DNA fingerprinting applications at a much lower cost than gel electrophoresis. Population screening for certain genetic disease can be a very efficient step to reducing medical costs through prevention. Since laser mass spectrometry can provide very fast DNA analysis, we applied laser mass spectrometry to disease diagnosis. Clinical samples with both base deletion and point mutation have been tested with complete success.

  9. The shape dependence of chameleon screening

    NASA Astrophysics Data System (ADS)

    Burrage, Clare; Copeland, Edmund J.; Moss, Adam; Stevenson, James A.

    2018-01-01

    Chameleon scalar fields can screen their associated fifth forces from detection by changing their mass with the local density. These models are an archetypal example of a screening mechanism, and have become an important target for both cosmological surveys and terrestrial experiments. In particular there has been much recent interest in searching for chameleon fifth forces in the laboratory. It is known that the chameleon force is less screened around non-spherical sources, but only the field profiles around a few simple shapes are known analytically. In this work we introduce a numerical code that solves for the chameleon field around arbitrary shapes with azimuthal symmetry placed in a spherical vacuum chamber. We find that deviations from spherical symmetry can increase the chameleon acceleration experienced by a test particle, and that the least screened objects are those which minimize some internal dimension. For the shapes considered in this work, keeping the mass, density and background environment fixed, the accelerations due to the source varied by a factor of ~ 3.

  10. Non-gassing nickel-cadmium battery electrodes and cells

    NASA Technical Reports Server (NTRS)

    Luksha, E.; Gordy, D. J.

    1972-01-01

    The concept of a negative limited nongassing nickel-cadmium battery was demonstrated by constructing and testing practical size experimental cells of approximately 25 Ah capacity. These batteries operated in a gas-free manner and had measured energy densities of 10-11 Wh/lb. Thirty cells were constructed for extensive testing. Some small cells were tested for over 200 cycles at 100% depth. For example, a small cell with an electrodeposited cadmium active mass on a silver screen still had 55% of its theoretical capacity (initial efficiency was 85%). There was no evidence of deterioration of gassing properties with cycling of the nickel electrodes. The charge temperature was observed to be the most critical variable governing nickel electrode gassing. This variable was shown to be age dependent. Four types of cadmium electrodes were tested: an electrodeposited cadmium active mass on a cadmium or silver substrate, a porous sintered silver substrate based electrode, and a Teflon bonded pressed cadmium electrode. The electrodeposited cadmium mass on a silver screen was found to be the best all-around electrode from a performance point of view and from the point of view of manufacturing them in a size required for a 25 Ah size battery.

  11. Using voids to unscreen modified gravity

    NASA Astrophysics Data System (ADS)

    Falck, Bridget; Koyama, Kazuya; Zhao, Gong-Bo; Cautun, Marius

    2018-04-01

    The Vainshtein mechanism, present in many models of gravity, is very effective at screening dark matter haloes such that the fifth force is negligible and general relativity is recovered within their Vainshtein radii. Vainshtein screening is independent of halo mass and environment, in contrast to e.g. chameleon screening, making it difficult to test. However, our previous studies have found that the dark matter particles in filaments, walls, and voids are not screened by the Vainshtein mechanism. We therefore investigate whether cosmic voids, identified as local density minima using a watershed technique, can be used to test models of gravity that exhibit Vainshtein screening. We measure density, velocity, and screening profiles of stacked voids in cosmological N-body simulations using both dark matter particles and dark matter haloes as tracers of the density field. We find that the voids are completely unscreened, and the tangential velocity and velocity dispersion profiles of stacked voids show a clear deviation from Λ cold dark matter at all radii. Voids have the potential to provide a powerful test of gravity on cosmological scales.

  12. Use of Breast Cancer Screening and Its Association with Later Use of Preventive Services among Medicare Beneficiaries.

    PubMed

    Kang, Stella K; Jiang, Miao; Duszak, Richard; Heller, Samantha L; Hughes, Danny R; Moy, Linda

    2018-06-05

    Purpose To retrospectively assess whether there is an association between screening mammography and the use of a variety of preventive services in women who are enrolled in Medicare. Materials and Methods U.S. Medicare claims from 2010 to 2014 Research Identifiable Files were reviewed to retrospectively identify a group of women who underwent screening mammography and a control group without screening mammography in 2012. The screened group was divided into positive versus negative results at screening, and the positive subgroup was divided into false-positive and true-positive findings. Multivariate logistic regression models and inverse probability of treatment weighting were used to examine the relationship between screening status and the probabilities of undergoing Papanicolaou test, bone mass measurement, or influenza vaccination in the following 2 years. Results The cohort consisted of 555 705 patients, of whom 185 625 (33.4%) underwent mammography. After adjusting for patient demographics, comorbidities, geographic covariates, and baseline preventive care, women who underwent index screening mammography (with either positive or negative results) were more likely than unscreened women to later undergo Papanicolaou test (odds ratio [OR], 1.49; 95% confidence interval: 1.40, 1.58), bone mass measurement (OR, 1.70; 95% confidence interval: 1.63, 1.78), and influenza vaccine (OR, 1.45; 95% confidence interval: 1.37, 1.53). In women who had not undergone these preventive measures in the 2 years before screening mammography, use of these three services after false-positive findings at screening was no different than after true-negative findings at screening. Conclusion In beneficiaries of U.S. Medicare, use of screening mammography was associated with higher likelihood of adherence to other preventive guidelines, without a negative association between false-positive results and cervical cancer screening. © RSNA, 2018 Online supplemental material is available for this article.

  13. Use of radioimmunoassay as a screen for antibiotics in confined animal feeding operations and confirmation by liquid chromatography/mass spectrometry

    USGS Publications Warehouse

    Meyer, M.T.; Bumgarner, J.E.; Varns, J.L.; Daughtridge, J.V.; Thurman, E.M.; Hostetler, K.A.

    2000-01-01

    Approximately one-half of the 50 000000 lb of antibiotics produced in the USA are used in agriculture. Because of the intensive use of antibiotics in the management of confined livestock operations, the potential exists for the transport of these compounds and their metabolites into our nation's water resources. A commercially available radioimmunoassay method, developed as a screen for tetracycline antibiotics in serum, urine, milk, and tissue, was adapted to analyze water samples at a detection level of approximately 1.0 ppb and a semiquantitative analytical range of 1-20 ppb. Liquid waste samples were obtained from 13 hog lagoons in three states and 52 surface- and ground-water samples were obtained primarily from areas associated with intensive swine and poultry production in seven states. These samples were screened for the tetracycline antibiotics by using the modified radioimmunoassay screening method. The radioimmunoassay tests yielded positive results for tetracycline antibiotics in samples from all 13 of the hog lagoons. Dilutions of 10-100-fold of the hog lagoon samples indicated that tetracycline antibiotic concentrations ranged from approximately 5 to several hundred parts per billion in liquid hog lagoon waste. Of the 52 surface- and ground-water samples collected all but two tested negative and these two samples contained tetracycline antibiotic concentrations less than 1 ppb. A new liquid chromatography/mass spectrometry method was used to confirm the radioimmunoassay results in 9 samples and also to identify the tetracycline antibiotics to which the radioimmunoassay test was responding. The new liquid chromatography/mass spectrometry method with online solid-phase extraction and a detection level of 0.5 ??g/l confirmed the presence of chlorotetracycline in the hog lagoon samples and in one of the surface-water samples. The concentrations calculated from the radioimmunoassay were a factor of 1-5 times less than those calculated by the liquid chromatography/mass spectrometry concentrations for chlorotetracycline. Copyright (C) 2000 Elsevier Science B.V.

  14. Impact of a primary care national policy on HIV screening in France: a longitudinal analysis between 2006 and 2013

    PubMed Central

    Sicsic, Jonathan; Saint-Lary, Olivier; Rouveix, Elisabeth; Pelletier-Fleury, Nathalie

    2016-01-01

    Background Early diagnosis of HIV infection is a major public health issue worldwide. In 2009, the French National Authority for Health (Haute Autorité de Santé) developed specific guidelines and recommended mass screening of 15–70-year-olds across the general population. The guidelines were supported by communication directed at healthcare professionals, especially GPs. Aim To assess the impact of the national mass screening policy on HIV testing. Design and setting The study used data from the French National Health Insurance Fund database, from January 2006 to December 2013. Males and females aged 15–70 years, excluding HIV-positive individuals and pregnant females, were followed up throughout the 2006–2013 period. During the study period, 2 176 657 person-years and a total of 329 748 different individuals were followed up. Method Standardised and non-standardised rates of HIV screening were calculated for each year; the impact of the policy was assessed using adjusted segmented regression analyses. Results Overall, annual HIV screening rates increased over the study period, from 4.2% (95% confidence interval [CI] = 4.2 to 4.3) in 2006 to 5.8% (95% CI = 5.7 to 5.9) in 2013 with a more pronounced trend after 2010 (P<0.0001). This increase was more significant for those who regularly consulted a GP. For these individuals, the policy led to a 20.4% increase (95% CI = 17.0 to 23.8) in HIV screening in 2013 compared with only a 4.5% increase (95% CI = 4.4 to 4.5) for those who did not consult a GP regularly in 2013. Conclusion The results show that the mass screening policy coordinated by GPs had a significant impact on HIV testing in France, which could result in positive impacts on public and individual health outcomes. PMID:27672140

  15. Thermal Protection System Aerothermal Screening Tests in HYMETS Facility

    NASA Technical Reports Server (NTRS)

    Szalai, Christine E.; Beck, Robin A. S.; Gasch, Matthew J.; Alumni, Antonella I.; Chavez-Garcia, Jose F.; Splinter, Scott C.; Gragg, Jeffrey G.; Brewer, Amy

    2011-01-01

    The Entry, Descent, and Landing (EDL) Technology Development Project has been tasked to develop Thermal Protection System (TPS) materials for insertion into future Mars Entry Systems. A screening arc jet test of seven rigid ablative TPS material candidates was performed in the Hypersonic Materials Environmental Test System (HYMETS) facility at NASA Langley Research Center, in both an air and carbon dioxide test environment. Recession, mass loss, surface temperature, and backface thermal response were measured for each test specimen. All material candidates survived the Mars aerocapture relevant heating condition, and some materials showed a clear increase in recession rate in the carbon dioxide test environment. These test results supported subsequent down-selection of the most promising material candidates for further development.

  16. Recent developments and new applications of tandem mass spectrometry in newborn screening.

    PubMed

    Rinaldo, Piero; Tortorelli, Silvia; Matern, Dietrich

    2004-08-01

    To summarize recent developments in the field of newborn screening related to the use of tandem mass spectrometry as an analytic platform. Novel inborn errors of metabolism with informative amino acid and/or acylcarnitine profiles have been characterized, increasing the complexity of the differential diagnosis of abnormal results. In addition, methods have been developed for the analysis in dried blood spots of steroids and lysosomal enzymes. Previously unrecognized genotype/phenotype correlations have been found among cohorts of patients whose conditions were diagnosed by screening rather than clinically. Several government entities and professional organizations have issued position statements on newborn screening, and worldwide outcome studies continue to underscore the clinical and financial benefits of expanded newborn screening. Although it is done inconsistently, newborn screening in the United States is undergoing a rapid expansion driven by the introduction of tandem mass spectrometry in at least 34 state programs. This technology is also used to detect disease markers beyond acylcarnitines and amino acids, as both primary and second-tier tests. In addition to analytic improvements, there is a trend toward the development of joint programs not limited to contiguous geographic areas, often based upon public-private partnerships. This review will summarize several new developments in the field that have occurred since early 2003 and will mention others likely to occur in the near future.

  17. Improved 5-year survival of patients with immunochemical faecal blood test-screen-detected colorectal cancer versus non-screening cancers in northern Italy.

    PubMed

    Parente, Fabrizio; Vailati, Cristian; Boemo, Cinzia; Bonoldi, Emanuela; Ardizzoia, Antonio; Ilardo, Antonina; Tortorella, Franco; Cereda, Danilo; Cremaschini, Marco; Moretti, Roberto

    2015-01-01

    Colorectal cancer screening may reduce disease-related mortality by early-stage detection of cancers. To study the effect of a single immunochemical faecal occult blood test (i-FOBt) screening round on reduction in colorectal cancer-related-mortality among average risk subjects. Comparison of 5-year mortality rates in 3 cohorts from a Northern Italian province: (1) colorectal cancers detected at the 1st biennial round of a mass-screening programme targeting 50-69 years old subjects, (2) non-screening cancers symptomatically diagnosed during the same time period, and (3) cancers detected in the pre-screening biennium. Multivariate analyses were performed with the Cox regression model including tumour node metastasis (TNM) stage at diagnosis, anatomical distribution of cancers, age at diagnosis, gender and patient group. Kaplan-Meyer survival estimates and log-rank test for equality of survivor functions were calculated. Stage distribution significantly differed between screening and non-screening colorectal cancers: 73% of screen-detected colorectal cancers were stages I and II versus 43% and 40% of non-screening and pre-screening colorectal cancers. Cumulative 5-year mortality rate was significantly lower in screening compared to non-screening or pre-screening colorectal cancers patients (19% versus 37% and 41%, p < 0.001). Colorectal cancers were detected at earlier stages in i-FOBT-positive subjects in comparison with non-screening patients; colorectal cancers found at screening had a significantly improved 5-year survival. Copyright © 2014 Editrice Gastroenterologica Italiana S.r.l. Published by Elsevier Ltd. All rights reserved.

  18. [Model project for updating neonatal screening in Bavaria: concept and initial results].

    PubMed

    Liebl, B; Fingerhut, R; Röschinger, W; Muntau, A; Knerr, I; Olgemöller, B; Zapf, A; Roscher, A A

    2000-04-01

    The newborn screening programme in Bavaria was confronted with several problems. Number of disorders and process quality no longer complied with screening guidelines. Mixed financing, distributed between the state (PKU, galactosaemia) and health insurances (hypothyroidism) had promoted an increasing dissipation of the system. Notified participation rates had dropped to < 80%. Increasing need for a second screening due to early discharge was an additional challenge. To overcome these problems, and considering the availability of improved screening methodology (tandem mass spectrometry) the programme was reorganised. The project, which started on Jan 1, 1999, is based on a cooperation model between laboratory (logistics, analysis), universities (treatment, scientific evaluation), and public health services (coordination, tracking). Time of blood sampling was predated to the third day of life. Screening was extended to biotinidase deficiency, congenital adrenal hyperplasia (CAH) and by introduction of tandem mass spectrometry for screening of many other disorders (besides PKU). Insurances now finance complete laboratory analysis which was transferred to the private sector. To enable all newborn to participate, the names of screened children are matched against birth lists by public health services on a regional basis. Recalls and conspicuous results are consistently followed up until disorders are either excluded or confirmed. Two clinical hotlines were established in the children's hospitals of the universities in Munich (Southern Bavaria) and in Erlangen (Northern Bavaria). Written consent is required for participation in the programme. Participation in the new programme could be continually increased; coverage is > 95% since April. In several cases screening was made up for not tested children by contacting their parents. Omitted screening was mostly due to misunderstandings regarding testing responsibility or lost samples. Altogether 52 cases of disorder were found in the 87,000 newborn screened until August 1999. Hence, the detection rate of children affected by inborn errors of metabolism was about twice as high than before changes. Among the newly screened diseases CAH was detected most often (11 cases). In 22 cases diagnosis was based on the use of tandem mass spectrometry. Among these (besides PKU, 9 cases) MCAD deficiency (6 cases) was detected most frequently. Whereas recall rates of most disorders were < 0.1%, screening for CAH still revealed a high recall rate, particularly in premature births. Second screening due to early discharge (< 48 h) was required in 1.3%. About 20% of pending recalls required contacting birth hospitals, doctors, midwives or parents. So far all affected children could be brought to treatment in time.

  19. Rapid methodology to screen flame retardants in upholstered furniture for compliance with new California labeling law (SB 1019).

    PubMed

    Petreas, Myrto; Gill, Ranjit; Takaku-Pugh, Sayaka; Lytle, Eric; Parry, Emily; Wang, Miaomiao; Quinn, John; Park, June-Soo

    2016-06-01

    In response to concerns regarding the widespread use of flame retardants, the California Legislature passed a law (SB1019) requiring labels on furniture products to indicate whether they do or do not contain flame retardants. To support the enforcement of the new law, our laboratory developed a step-wise, screening approach to test for brominated (BFR) and phosphorus-based flame retardants (OPFRs) in several types of furniture components (foam, fabric, batting, plumage, etc.). We used X-Ray Fluorescence (XRF) to screen for the presence of Br (and other elements) and Inductively Coupled Plasma - Optical Emission Spectrometry (ICP-OES) to identify and measure the concentration of P (and other elements). The same samples were also extracted by dichloromethane using sonication and analyzed by a single injection into a Gas Chromatograph - Tandem Mass Spectrometer to obtain concentrations of specific BFRs and OPFRs. Our approach showed excellent screening potential for Br and Sb by XRF and for P by ICP-OES, with both tests having predictive values of a negative equal to 1. To explore and screen for flame retardants in products not included in our current list of target chemicals, we used Liquid Chromatography/Time-of-Flight Mass Spectrometry operated with electrospray ionization, to identify additional flame retardants to be incorporated in quantitative methods. We are making all our methodologies public to facilitate simple and low cost methods that can help manufacturers and suppliers have their products tested and correctly labeled, ultimately benefitting the consumer. Copyright © 2016 Elsevier Ltd. All rights reserved.

  20. Population screening for glucose-6-phosphate dehydrogenase deficiencies in Isabel Province, Solomon Islands, using a modified enzyme assay on filter paper dried bloodspots

    PubMed Central

    2010-01-01

    Background Glucose-6-phosphate dehydrogenase deficiency poses a significant impediment to primaquine use for the elimination of liver stage infection with Plasmodium vivax and for gametocyte clearance, because of the risk of life-threatening haemolytic anaemia that can occur in G6PD deficient patients. Although a range of methods for screening G6PD deficiency have been described, almost all require skilled personnel, expensive laboratory equipment, freshly collected blood, and are time consuming; factors that render them unsuitable for mass-screening purposes. Methods A published WST8/1-methoxy PMS method was adapted to assay G6PD activity in a 96-well format using dried blood spots, and used it to undertake population screening within a malaria survey undertaken in Isabel Province, Solomon Islands. The assay results were compared to a biochemical test and a recently marketed rapid diagnostic test. Results Comparative testing with biochemical and rapid diagnostic test indicated that results obtained by filter paper assay were accurate providing that blood spots were assayed within 5 days when stored at ambient temperature and 10 days when stored at 4 degrees. Screening of 8541 people from 41 villages in Isabel Province, Solomon Islands revealed the prevalence of G6PD deficiency as defined by enzyme activity < 30% of normal control was 20.3% and a prevalence of severe deficiency that would predispose to primaquine-induced hemolysis (WHO Class I-II) of 6.9%. Conclusions The assay enabled simple and quick semi-quantitative population screening in a malaria-endemic region. The study indicated a high prevalence of G6PD deficiency in Isabel Province and highlights the critical need to consider G6PD deficiency in the context of P. vivax malaria elimination strategies in Solomon Islands, particularly in light of the potential role of primaquine mass drug administration. PMID:20684792

  1. Population screening for glucose-6-phosphate dehydrogenase deficiencies in Isabel Province, Solomon Islands, using a modified enzyme assay on filter paper dried bloodspots.

    PubMed

    Kuwahata, Melissa; Wijesinghe, Rushika; Ho, Mei-Fong; Pelecanos, Anita; Bobogare, Albino; Landry, Losi; Bugora, Hugo; Vallely, Andrew; McCarthy, James

    2010-08-05

    Glucose-6-phosphate dehydrogenase deficiency poses a significant impediment to primaquine use for the elimination of liver stage infection with Plasmodium vivax and for gametocyte clearance, because of the risk of life-threatening haemolytic anaemia that can occur in G6PD deficient patients. Although a range of methods for screening G6PD deficiency have been described, almost all require skilled personnel, expensive laboratory equipment, freshly collected blood, and are time consuming; factors that render them unsuitable for mass-screening purposes. A published WST8/1-methoxy PMS method was adapted to assay G6PD activity in a 96-well format using dried blood spots, and used it to undertake population screening within a malaria survey undertaken in Isabel Province, Solomon Islands. The assay results were compared to a biochemical test and a recently marketed rapid diagnostic test. Comparative testing with biochemical and rapid diagnostic test indicated that results obtained by filter paper assay were accurate providing that blood spots were assayed within 5 days when stored at ambient temperature and 10 days when stored at 4 degrees. Screening of 8541 people from 41 villages in Isabel Province, Solomon Islands revealed the prevalence of G6PD deficiency as defined by enzyme activity < 30% of normal control was 20.3% and a prevalence of severe deficiency that would predispose to primaquine-induced hemolysis (WHO Class I-II) of 6.9%. The assay enabled simple and quick semi-quantitative population screening in a malaria-endemic region. The study indicated a high prevalence of G6PD deficiency in Isabel Province and highlights the critical need to consider G6PD deficiency in the context of P. vivax malaria elimination strategies in Solomon Islands, particularly in light of the potential role of primaquine mass drug administration.

  2. Mass Detection in Mammographic Images Using Wavelet Processing and Adaptive Threshold Technique.

    PubMed

    Vikhe, P S; Thool, V R

    2016-04-01

    Detection of mass in mammogram for early diagnosis of breast cancer is a significant assignment in the reduction of the mortality rate. However, in some cases, screening of mass is difficult task for radiologist, due to variation in contrast, fuzzy edges and noisy mammograms. Masses and micro-calcifications are the distinctive signs for diagnosis of breast cancer. This paper presents, a method for mass enhancement using piecewise linear operator in combination with wavelet processing from mammographic images. The method includes, artifact suppression and pectoral muscle removal based on morphological operations. Finally, mass segmentation for detection using adaptive threshold technique is carried out to separate the mass from background. The proposed method has been tested on 130 (45 + 85) images with 90.9 and 91 % True Positive Fraction (TPF) at 2.35 and 2.1 average False Positive Per Image(FP/I) from two different databases, namely Mammographic Image Analysis Society (MIAS) and Digital Database for Screening Mammography (DDSM). The obtained results show that, the proposed technique gives improved diagnosis in the early breast cancer detection.

  3. Gravimetric screening method for fungal decay of paper: inoculation with Trametes versicolor.

    PubMed

    Råberg, Ulrika; Hafrén, Jonas

    2009-10-01

    The European standard test EN 113 for fungal degradation of solid wood has been adapted for degradation of paper by white rot fungus (Trametes versicolor). Fungal degradation of paper sheets may potentially be used for screening different wood preservatives on paper instead of solid wood. The paper samples showed higher relative mass losses compared to wood, and samples pretreated with boric acid, copper sulfate and polymerized linseed oil were successfully tested for biodegradation using the paper sheet method. The results on paper degradation were compared with wood, both as wood blocks (according to standard test) and wood cut in sections forming layered structures mimicking paper layers.

  4. Application of matrix-assisted laser desorption ionization time-of-flight mass spectrometry in the screening of vanA-positive Enterococcus faecium.

    PubMed

    Wang, Li-jun; Lu, Xin-xin; Wu, Wei; Sui, Wen-jun; Zhang, Gui

    2014-01-01

    In order to evaluate a rapid matrix-assisted laser desorption ionization-time of flight mass spectrometry (MAIDI-TOF MS) assay in screening vancomycin-resistant Enterococcus faecium, a total of 150 E. faecium clinical strains were studied, including 60 vancomycin-resistant E. faecium (VREF) isolates and 90 vancomycin-susceptible (VSEF) strains. Vancomycin resistance genes were detected by sequencing. E. faecium were identified by MALDI-TOF MS. A genetic algorithm model with ClinProTools software was generated using spectra of 30 VREF isolates and 30 VSEF isolates. Using this model, 90 test isolates were discriminated between VREF and VSEF. The results showed that all sixty VREF isolates carried the vanA gene. The performance of VREF detection by the genetic algorithm model of MALDI-TOF MS compared to the sequencing method was sensitivity = 80%, specificity = 90%, false positive rate =10%, false negative rate =10%, positive predictive value = 80%, negative predictive value= 90%. MALDI-TOF MS can be used as a screening test for discrimination between vanA-positive E. faecium and vanA-negative E. faecium.

  5. Comprehensive Mechanistic Analysis of Hits from High-Throughput and Docking Screens against β-Lactamase

    PubMed Central

    Babaoglu, Kerim; Simeonov, Anton; Irwin, John J.; Nelson, Michael E.; Feng, Brian; Thomas, Craig J.; Cancian, Laura; Costi, M. Paola; Maltby, David A.; Jadhav, Ajit; Inglese, James; Austin, Christopher P.; Shoichet, Brian K.

    2009-01-01

    High-throughput screening (HTS) is widely used in drug discovery. Especially for screens of unbiased libraries, false positives can dominate “hit lists”; their origins are much debated. Here we determine the mechanism of every active hit from a screen of 70,563 unbiased molecules against β-lactamase using quantitative HTS (qHTS). Of the 1274 initial inhibitors, 95% were detergent-sensitive and were classified as aggregators. Among the 70 remaining were 25 potent, covalent-acting β-lactams. Mass spectra, counter-screens, and crystallography identified 12 as promiscuous covalent inhibitors. The remaining 33 were either aggregators or irreproducible. No specific reversible inhibitors were found. We turned to molecular docking to prioritize molecules from the same library for testing at higher concentrations. Of 16 tested, 2 were modest inhibitors. Subsequent X-ray structures corresponded to the docking prediction. Analog synthesis improved affinity to 8 µM. These results suggest that it may be the physical behavior of organic molecules, not their reactivity, that accounts for most screening artifacts. Structure-based methods may prioritize weak-but-novel chemotypes in unbiased library screens. PMID:18333608

  6. Urban-rural difference in the acceptance of mass health examination in north-eastern Japan.

    PubMed

    Ikeda, M; Nakatsuka, H; Watanabe, T; Hisamichi, S; Shimizu, H; Fujisaku, S; Ichinowatari, Y; Konno, J; Kuroda, S; Hirai, J

    1989-05-01

    Over 40,000 residents (less than or equal to 40 years of age) in a city (Sendai; the city group), a town (Shiroishi; the town group) and two villages (Wakuya and Tajiri; the village group) in Miyagi prefecture in north-eastern Japan responded in a questionnaire survey on their attitude towards mass health examinations (i.e., whether they underwent in the previous year and if so where) on 4 items of blood pressure measurement, chest x-ray examination and screening tests for stomach and cervical cancer. The coverage rates were about 70% on an average both for blood pressure measurement and for chest x-ray examination, whereas the rates for cancer screening were between 30-40%. As for the opportunity of the former two examinations, the workplace mass examination played a large role in the case of the city and town groups (especially among men but not women) in addition to visit to clinics, in contrast to the case of the village group in which people depended much on regional mass examination service. The trend was essentially reproducible in stomach cancer screening although the over-all coverage rate was low, whereas women in the three groups almost exclusively utilized clinics for cervical cancer screening with one exception that the mobile unit service appeared to be equally accepted in the village group.

  7. Evaluation of a direct high-capacity target screening approach for urine drug testing using liquid chromatography-time-of-flight mass spectrometry.

    PubMed

    Saleh, Aljona; Stephanson, Niclas Nikolai; Granelli, Ingrid; Villén, Tomas; Beck, Olof

    2012-11-15

    In this study a rapid liquid chromatography-time-of-flight mass spectrometry method was developed, validated and applied in order to evaluate the potential of this technique for routine urine drug testing. Approximately 800 authentic patient samples were analyzed for amphetamines (amphetamine and methamphetamine), opiates (morphine, morphine-3-glucuronide, morphine-6-glucuronide, codeine and codeine-6-glucuronide) and buprenorphines (buprenorphine and buprenorphine-glucuronide) using immunochemical screening assays and mass spectrometry confirmation methods for comparison. The chromatographic application utilized a rapid gradient with high flow and a reversed phase column with 1.8 μm particles. Total analysis time was 4 min. The mass spectrometer operated with an electrospray interface in positive mode with a resolution power of >10,000 at m/z 956. The applied reporting limits were 100 ng/mL for amphetamines and opiates, and 5 ng/mL for buprenorphines, with lower limits of quantification were 2.8-41 ng/mL. Calibration curves showed a linear response with coefficients of correlation of 0.97-0.99. The intra- and interday imprecision in quantification at the reporting limits were <10% for all analytes but for buprenorphines <20%. Method validation data met performance criteria for a qualitative and quantitative method. The liquid chromatography-time-of-flight mass spectrometry method was found to be more selective than the immunochemical method by producing lower rates of false positives (0% for amphetamines and opiates; 3.2% for buprenorphines) and negatives (1.8% for amphetamines; 0.6% for opiates; 0% for buprenorphines). The overall agreement between the two screening methods was between 94.2 and 97.4%. Comparison of data with the confirmation (LC-MS) results for all individual 9 analytes showed that most deviating results were produced in samples with low levels of analytes. False negatives were mainly related to failure of detected peak to meet mass accuracy criteria (±20 mDa). False positives was related to presence of interfering peaks meeting mass accuracy and retention time criteria and occurred mainly at low levels. It is concluded that liquid chromatography-time-of-flight mass spectrometry has potential both as a complement and as replacement of immunochemical screening assays. Copyright © 2012 Elsevier B.V. All rights reserved.

  8. Rapid extraction, identification and quantification of drugs of abuse in hair by immunoassay and ultra-performance liquid chromatography tandem mass spectrometry.

    PubMed

    Pichini, Simona; Gottardi, Massimo; Marchei, Emilia; Svaizer, Fiorenza; Pellegrini, Manuela; Rotolo, Maria Concetta; Algar, Oscar García; Pacifici, Roberta

    2014-05-01

    Drug testing in hair is a unique analysis in pharmacotoxicology for establishing a past repeated history of consumption or passive exposure to psychotropic substances. A rather lengthy sample treatment is usually required before parent drugs and eventual metabolites are amenable to quali-quantitative analysis. We evaluated a high throughput screening and confirmation analysis of drugs of abuse in hair by immunoassay and a validated ultra-performance liquid chromatography tandem mass spectrometry (UPLC-MS/MS) after applying a rapid digestion of the keratin matrix with VMA-T reagent before screening assay and M3 reagent before confirmatory analysis. Samples digestion with VMA-T reagent and immunometric screening analysis of hair calibrators, controls and clinical samples for a total of 150 samples was completed in 4 h. No false-positive and -negative results were found for the control material. UPLC-MS/MS analysis confirmed all of the 31 adult hair samples positive to the screening test using internationally established cut-offs, and identified and quantified drugs of abuse in 32 pediatric hair samples, applying lower limits of quantification from 0.01 to 0.1 ng analyte per mg hair. Analytical recovery was between 70.9% and 100.7%. Intra- and inter-assay imprecision and inaccuracy were always lower than 10%. Rapid extraction, identification and quantification of drugs of abuse in hair by immunoassay and UPLC-MS/MS was tested for its feasibility in clinical samples and provided excellent results for rapid and effective drug testing in hair in epidemiological studies.

  9. Use of the Analysis of the Volatile Faecal Metabolome in Screening for Colorectal Cancer

    PubMed Central

    2015-01-01

    Diagnosis of colorectal cancer is an invasive and expensive colonoscopy, which is usually carried out after a positive screening test. Unfortunately, existing screening tests lack specificity and sensitivity, hence many unnecessary colonoscopies are performed. Here we report on a potential new screening test for colorectal cancer based on the analysis of volatile organic compounds (VOCs) in the headspace of faecal samples. Faecal samples were obtained from subjects who had a positive faecal occult blood sample (FOBT). Subjects subsequently had colonoscopies performed to classify them into low risk (non-cancer) and high risk (colorectal cancer) groups. Volatile organic compounds were analysed by selected ion flow tube mass spectrometry (SIFT-MS) and then data were analysed using both univariate and multivariate statistical methods. Ions most likely from hydrogen sulphide, dimethyl sulphide and dimethyl disulphide are statistically significantly higher in samples from high risk rather than low risk subjects. Results using multivariate methods show that the test gives a correct classification of 75% with 78% specificity and 72% sensitivity on FOBT positive samples, offering a potentially effective alternative to FOBT. PMID:26086914

  10. Faecal occult blood screening for colorectal cancer in Serbia: a pilot study.

    PubMed

    Scepanovic, Milena; Jovanovic, Olivera; Keber, Dusan; Jovanovic, Ivan; Miljus, Dragan; Nikolic, Goran; Kovacevic, Bojan; Pavlovic, Aleksandra; Dugalic, Predrag; Nagorni, Aleksandar; Grgov, Sasa; Knezevic, Slavko; Milenkovic, Predrag; Perisic, Nenad; Faivre, Jean

    2017-05-01

    Colorectal cancer (CRC) is becoming a major public health problem in the Republic of Serbia. Organized mass screening has been shown to decrease CRC mortality and even its incidence. The aim of this study was to assess the acceptability of a faecal immunochemical test for haemoglobin proposed by primary care physicians. From August to November 2013, a pilot study for CRC screening was organized in individuals aged 50 to 74 years. The study included 50 primary healthcare centres from all 25 administrative regions of Serbia. A qualitative immunochromatographic faecal immunochemical test for human haemoglobin detection was used. Overall, 50 894 individuals were invited. The participation rate was 67.8 and 3.4% of the tests were positive. Among individuals with a positive test, 69.7% agreed to undergo colonoscopy. The positive predictive value was 27.1% for adenoma and 14.6% for carcinoma. This was the first CRC screening project encompassing approximately one-third of primary healthcare facilities in all regions across the country. It showed a good response of the target population and satisfactory cooperation of the healthcare professionals involved.

  11. Comparative Evaluation of Preliminary Screening Methods for Colorectal Cancer in a Mass Program.

    PubMed

    Ye, Ding; Huang, Qiuchi; Li, Qilong; Jiang, Xiyi; Mamat, Mayila; Tang, Mengling; Wang, Jianbing; Chen, Kun

    2017-09-01

    The fecal immunochemical test (FIT) has been widely used in preliminary screening for colorectal cancer (CRC). The high-risk factor questionnaire (HRFQ) and quantitative risk-assessment method (QRAM) are recommended for estimating the risk of CRC qualitatively and quantitatively in China. We aimed to prospectively compare the diagnostic values of CRC preliminary screening methods to identify which method is preferable as a screening strategy. Individuals aged 40-74 years old were enrolled in a mass CRC screening program from January 1, 2007 to December 31, 2014, in Jiashan County, Zhejiang Province, China. FIT of two stool specimens at 1-week intervals was performed by laboratory personnel and face-to-face interviews were conducted by trained investigators. Screening data in the program were linked to a CRC surveillance and registry system, and CRC cases reported in the system were regarded as true patients. A total of 96,043 subjects were included. The sensitivity and specificity of FIT for detecting CRC cases were 75.49% (95% CI 69.84-80.39) and 90.36% (95% CI 90.17-90.54), respectively. QRAM was more sensitive (p < 0.001) and less specific (p < 0.001) than HRFQ. The sensitivity and specificity of FIT along with HRFQ were 86.56% (95% CI 81.81-90.22) and 81.37% (95% CI 81.12-81.62), and those of FIT along with QRAM were 88.93% (95% CI 84.47-92.23) and 73.95% (95% CI 73.67-74.23). Our findings suggest that CRC preliminary screening with FIT and QRAM in parallel has high sensitivity and satisfactory specificity, and is a useful strategy in mass screening programs.

  12. Current State of and Needs for Hepatitis B Screening: Results of a Large Screening Study in a Low-Prevalent, Metropolitan Region

    PubMed Central

    Bottero, Julie; Boyd, Anders; Lemoine, Maud; Carrat, Fabrice; Gozlan, Joel; Collignon, Anne; Boo, Nicolas; Dhotte, Philippe; Varsat, Brigitte; Muller, Gerard; Cha, Olivier; Valin, Nadia; Nau, Jean; Campa, Pauline; Silbermann, Benjamin; Bary, Marc; Girard, Pierre-Marie; Lacombe, Karine

    2014-01-01

    Background In low hepatitis B virus (HBV)-prevalent countries, most HBV-infected persons are unaware of their status. We aimed to evaluate whether (i) previous HBV-testing, (ii) physicians decision to screen, and (iii) CDC's recommendations identified infected individuals and which risk-factor groups needing testing. Methods During a mass, multi-center HBV-screening study from September 2010-August 2011, 3929 participants were screened for hepatitis B surface antigen (HBsAg), anti-HBs and anti-Hepatitis B core antibodies (anti-HBcAb). Questions on HBV risk-factors and testing practices were asked to participants, while participants' eligibility for HBV-testing was asked to study medical professionals. Results 85 (2.2%) participants were HBsAg-positive, while 659 (16.8%) had either resolved HBV infection or isolated anti-HBcAb. When comparing practices, HBV-testing was more likely to occur in HBV-infected participants if Centers for Disease Control and Prevention (CDC) recommendations were used (Sensitivity = 100%, 95%CI: 95.8–100) than physicians' discretion (Sensitivity = 87.1%, 95%CI: 78.0–93.4) or previous HBV-test (Sensitivity = 36.5%, 95%CI: 26.3–47.6) (p<0.0001). Nevertheless, many non-infected individuals would still have been screened using CDC-recommendations (Specificity = 31.1%, 95%CI: 29.6–32.6). Using multivariable logistic regression, HBsAg-positive status was significantly associated with the following: males, originating from high HBV-endemic region, contact with HBV-infected individual, without national healthcare, and intravenous-drug user (IDU). Of these risk-factors, physician's discretion for testing HBV was not significantly associated with participants' geographical origin or IDU. Conclusions Missed opportunities of HBV-screening are largely due to underestimating country of origin as a risk-factor. Applying CDC-recommendations could improve HBV-screening, but with the disadvantage of many tests. Further development of HBV-testing strategies is necessary, especially before severe disease occurs. PMID:24663387

  13. Current state of and needs for hepatitis B screening: results of a large screening study in a low-prevalent, metropolitan region.

    PubMed

    Bottero, Julie; Boyd, Anders; Lemoine, Maud; Carrat, Fabrice; Gozlan, Joel; Collignon, Anne; Boo, Nicolas; Dhotte, Philippe; Varsat, Brigitte; Muller, Gerard; Cha, Olivier; Valin, Nadia; Nau, Jean; Campa, Pauline; Silbermann, Benjamin; Bary, Marc; Girard, Pierre-Marie; Lacombe, Karine

    2014-01-01

    In low hepatitis B virus (HBV)-prevalent countries, most HBV-infected persons are unaware of their status. We aimed to evaluate whether (i) previous HBV-testing, (ii) physicians decision to screen, and (iii) CDC's recommendations identified infected individuals and which risk-factor groups needing testing. During a mass, multi-center HBV-screening study from September 2010-August 2011, 3929 participants were screened for hepatitis B surface antigen (HBsAg), anti-HBs and anti-Hepatitis B core antibodies (anti-HBcAb). Questions on HBV risk-factors and testing practices were asked to participants, while participants' eligibility for HBV-testing was asked to study medical professionals. 85 (2.2%) participants were HBsAg-positive, while 659 (16.8%) had either resolved HBV infection or isolated anti-HBcAb. When comparing practices, HBV-testing was more likely to occur in HBV-infected participants if Centers for Disease Control and Prevention (CDC) recommendations were used (Sensitivity = 100%, 95%CI: 95.8-100) than physicians' discretion (Sensitivity = 87.1%, 95%CI: 78.0-93.4) or previous HBV-test (Sensitivity = 36.5%, 95%CI: 26.3-47.6) (p<0.0001). Nevertheless, many non-infected individuals would still have been screened using CDC-recommendations (Specificity = 31.1%, 95%CI: 29.6-32.6). Using multivariable logistic regression, HBsAg-positive status was significantly associated with the following: males, originating from high HBV-endemic region, contact with HBV-infected individual, without national healthcare, and intravenous-drug user (IDU). Of these risk-factors, physician's discretion for testing HBV was not significantly associated with participants' geographical origin or IDU. Missed opportunities of HBV-screening are largely due to underestimating country of origin as a risk-factor. Applying CDC-recommendations could improve HBV-screening, but with the disadvantage of many tests. Further development of HBV-testing strategies is necessary, especially before severe disease occurs.

  14. Screening for tuberculosis and testing for human immunodeficiency virus in Zambian prisons

    PubMed Central

    Maggard, Katie R; Hatwiinda, Sisa; Harris, Jennifer B; Phiri, Winifreda; Krüüner, Annika; Kaunda, Kaunda; Topp, Stephanie M; Kapata, Nathan; Ayles, Helen; Chileshe, Chisela; Henostroza, German

    2015-01-01

    Abstract Objective To improve the Zambia Prisons Service’s implementation of tuberculosis screening and human immunodeficiency virus (HIV) testing. Methods For both tuberculosis and HIV, we implemented mass screening of inmates and community-based screening of those residing in encampments adjacent to prisons. We also established routine systems – with inmates as peer educators – for the screening of newly entered or symptomatic inmates. We improved infection control measures, increased diagnostic capacity and promoted awareness of tuberculosis in Zambia’s prisons. Findings In a period of 9 months, we screened 7638 individuals and diagnosed 409 new patients with tuberculosis. We tested 4879 individuals for HIV and diagnosed 564 cases of infection. An additional 625 individuals had previously been found to be HIV-positive. Including those already on tuberculosis treatment at the time of screening, the prevalence of tuberculosis recorded in the prisons and adjacent encampments – 6.4% (6428/100 000) – is 18 times the national prevalence estimate of 0.35%. Overall, 22.9% of the inmates and 13.8% of the encampment residents were HIV-positive. Conclusion Both tuberculosis and HIV infection are common within Zambian prisons. We enhanced tuberculosis screening and improved the detection of tuberculosis and HIV in this setting. Our observations should be useful in the development of prison-based programmes for tuberculosis and HIV elsewhere. PMID:25883402

  15. Guilty by dissociation-development of gas chromatography-mass spectrometry (GC-MS) and other rapid screening methods for the analysis of 13 diphenidine-derived new psychoactive substances (NPSs).

    PubMed

    Geyer, Pierre M; Hulme, Matthew C; Irving, Joseph P B; Thompson, Paul D; Ashton, Ryan N; Lee, Robert J; Johnson, Lucy; Marron, Jack; Banks, Craig E; Sutcliffe, Oliver B

    2016-11-01

    The prevalence of new psychoactive substances (NPSs) in forensic casework has increased prominently in recent years. This has given rise to significant legal and analytical challenges in the identification of these substances. The requirement for validated, robust and rapid testing methodologies for these compounds is obvious. This study details the analysis of 13 synthesised diphenidine derivatives encountered in casework using presumptive testing, thin layer chromatography and gas chromatography-mass spectrometry (GC-MS). Specifically, the validated GC-MS method provides, for the first time, both a general screening method and quantification of the active components for seized solid samples, both in their pure form and in the presence of common adulterants. Graphical Abstract Chemical synthesis and forensic analysis of 13 diphenidine-derived new psychoactive substance(s).

  16. How can the uptake of cervical cytology screening be improved?

    PubMed

    Perry, M A

    Cervical cancer remains a killer, despite a screening programme designed to detect cases in the early stages of development. A number of factors appear to influence a woman's decision to attend for a smear test. This literature review considers these factors, and whether nurses can play a part in reducing the death rate by dispelling the misapprehensions and misinformation that deter vulnerable women from attending. There is a great need for modification and improvement of the present screening programme if all women who are at risk from cervical cancer are to be encouraged to attend for screening. The attitude of those who conduct smear tests is often crucial in gaining women's confidence--an unpleasant experience might deter a patient from attending again. Other barriers to attendance include administrative errors and lack of knowledge. Given the impact of mass advertising and health promotion campaigns in other areas, such as smoking cessation, there is clearly a need for a similar strategy to be applied to cervical screening.

  17. Development of an Automated Modality-Independent Elastographic Image Analysis System for Tumor Screening

    DTIC Science & Technology

    2006-02-01

    further develop modality-independent elastography as a system that is able to reproducibly detect regions of increased stiffness within the breast based...tested on a tissue-like polymer phantom. elastography , breast cancer screening, image processing 16. SECURITY CLASSIFICATION OF: 17. LIMITATION...is a map of the breast (or other tissue of interest) that reflects material inhomogeneity, such as in the case of a tumor mass that disrupts the

  18. Haemoglobinopathy diagnosis: algorithms, lessons and pitfalls.

    PubMed

    Bain, Barbara J

    2011-09-01

    Diagnosis of haemoglobinopathies, including thalassaemias, can result from either a clinical suspicion of a disorder of globin chain synthesis or from follow-up of an abnormality detected during screening. Screening may be carried out as part of a well defined screening programme or be an ad hoc or opportunistic test. Screening may be preoperative, neonatal, antenatal, preconceptual, premarriage or targeted at specific groups perceived to be at risk. Screening in the setting of haemoglobinopathies may be directed at optimising management of a disorder by early diagnosis, permitting informed reproductive choice or preventing a serious disorder by offering termination of pregnancy. Diagnostic methods and algorithms will differ according to the setting. As the primary test, high performance liquid chromatography is increasingly used and haemoglobin electrophoresis less so with isoelectric focussing being largely confined to screening programmes and referral centres, particularly in newborns. Capillary electrophoresis is being increasingly used. All these methods permit only a presumptive diagnosis with definitive diagnosis requiring either DNA analysis or protein analysis, for example by tandem mass spectrometry. Copyright © 2011 Elsevier Ltd. All rights reserved.

  19. Computer-aided detection of breast masses: Four-view strategy for screening mammography

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Wei Jun; Chan Heangping; Zhou Chuan

    2011-04-15

    Purpose: To improve the performance of a computer-aided detection (CAD) system for mass detection by using four-view information in screening mammography. Methods: The authors developed a four-view CAD system that emulates radiologists' reading by using the craniocaudal and mediolateral oblique views of the ipsilateral breast to reduce false positives (FPs) and the corresponding views of the contralateral breast to detect asymmetry. The CAD system consists of four major components: (1) Initial detection of breast masses on individual views, (2) information fusion of the ipsilateral views of the breast (referred to as two-view analysis), (3) information fusion of the corresponding viewsmore » of the contralateral breast (referred to as bilateral analysis), and (4) fusion of the four-view information with a decision tree. The authors collected two data sets for training and testing of the CAD system: A mass set containing 389 patients with 389 biopsy-proven masses and a normal set containing 200 normal subjects. All cases had four-view mammograms. The true locations of the masses on the mammograms were identified by an experienced MQSA radiologist. The authors randomly divided the mass set into two independent sets for cross validation training and testing. The overall test performance was assessed by averaging the free response receiver operating characteristic (FROC) curves of the two test subsets. The FP rates during the FROC analysis were estimated by using the normal set only. The jackknife free-response ROC (JAFROC) method was used to estimate the statistical significance of the difference between the test FROC curves obtained with the single-view and the four-view CAD systems. Results: Using the single-view CAD system, the breast-based test sensitivities were 58% and 77% at the FP rates of 0.5 and 1.0 per image, respectively. With the four-view CAD system, the breast-based test sensitivities were improved to 76% and 87% at the corresponding FP rates, respectively. The improvement was found to be statistically significant (p<0.0001) by JAFROC analysis. Conclusions: The four-view information fusion approach that emulates radiologists' reading strategy significantly improves the performance of breast mass detection of the CAD system in comparison with the single-view approach.« less

  20. Mass media as a population-level intervention tool for Chlamydia trachomatis screening: report of a pilot study.

    PubMed

    Oh, M Kim; Grimley, Diane M; Merchant, Jeanne S; Brown, Pernell R; Cecil, Heather; Hook, Edward W

    2002-07-01

    To determine the feasibility and affect of mass media use in a population-level intervention for chlamydia screening promotion. A population-level chlamydia intervention protocol was field tested. The intervention, targeting 15-25-year-old individuals, was designed to: (a) increase awareness of personal risk for chlamydial infection; (b) facilitate dissemination of chlamydia knowledge by use of a telephone hot line; and (c) promote care-seeking behavior (report for a chlamydia screening program). The intervention activities included: (a) mail outreach, (b) a television and radio campaign, (c) a prerecorded Check-It-Out chlamydia hot line, (d) a staffed chlamydia Options information line, and (e) a free confidential urine ligase chain reaction (LCR) test for chlamydia. Mass mailings were scheduled at intervals, starting two-weeks before the beginning of the television advertisement. The 30-second television advertisement was aired on local television stations 130 times in a 6-week period. The outcome measures were quantity and characteristics of incoming calls to the automated hot line and staffed chlamydia information phone line in response to the chlamydia campaign, and response to the urine screening program. Descriptive and bivariate analyses were used to evaluate the outcomes. The hot line was called 642 times during the monitoring period (November 1, 1999 to March 8, 2000), the majority (92%) during the 6 weeks of television advertisement, with an average of 99 calls per week, compared with an average of 9 calls per week after the commercial ended. Each bulk mailing was accompanied by a boost in the incoming hot line calls. The research staff triaged 133 calls to the "Options" phone line, 81% in the 6 weeks of the TV ad. The mean age of the 133 callers was 23.9 +/- 7.7 years (range 14-49 years). A majority called for screening information; 67% of callers were females and 84% of female callers were under age 26 years. Five percent of callers identified themselves as a parent of a teenager. The majority credited the TV ad as their source of the hot line number. Thirty-one individuals reported for a confidential chlamydia screening, 27 of 31 (87%) during the 6 weeks of TV advertising. No negative responses regarding the chlamydia campaign were encountered. This report describes strategies used to implement and measure the effectiveness of a mass media campaign and demonstrates evidence that mass media is effective in delivering STD intervention messages to young people.

  1. Syringe test screening of microbial gas production activity: Cases denitrification and biogas formation.

    PubMed

    Østgaard, Kjetill; Kowarz, Viktoria; Shuai, Wang; Henry, Ingrid A; Sposob, Michal; Haugen, Hildegunn Hegna; Bakke, Rune

    2017-01-01

    Mass produced plastic syringes may be applied as vessels for cheap, simple and large scale batch culture testing. As illustrated for the cases of denitrification and of biogas formation, metabolic activity was monitored by direct reading of the piston movement due to the gas volume formed. Pressure buildup due to friction was shown to be moderate. A piston pull and slide back routine can be applied before recording gas volume to minimize experimental errors due to friction. Inoculum handling and activity may be conveniently standardized as illustrated by applying biofilm carriers. A robust set of positive as well as negative controls ("blanks") should be included to ensure quality of the actual testing. The denitrification test showed saturation response at increasing amounts of inoculum in the form of adapted moving bed biofilm reactor (MBBR) carriers, with well correlated nitrate consumption vs. gas volume formed. As shown, the denitrification test efficiently screened different inocula at standardized substrates. Also, different substrates were successfully screened and compared at standardized inocula. The biogas potential test showed efficient screening of different substrates with effects of relative amounts of carbohydrate, protein, fat. A second case with CO 2 capture reclaimer waste as substrate demonstrated successful use of co-feeding to support waste treatment and how temperature effects on kinetics and stoichiometry can be observed. In total, syringe test screening of microbial gas production seems highly efficient at a low cost when properly applied. Copyright © 2016 Elsevier B.V. All rights reserved.

  2. Parameterised post-Newtonian expansion in screened regions

    NASA Astrophysics Data System (ADS)

    McManus, Ryan; Lombriser, Lucas; Peñarrubia, Jorge

    2017-12-01

    The parameterised post-Newtonian (PPN) formalism has enabled stringent tests of static weak-field gravity in a theory-independent manner. Here we incorporate screening mechanisms of modified gravity theories into the framework by introducing an effective gravitational coupling and defining the PPN parameters as functions of position. To determine these functions we develop a general method for efficiently performing the post-Newtonian expansion in screened regimes. For illustration, we derive all the PPN functions for a cubic galileon and a chameleon model. We also analyse the Shapiro time delay effect for these two models and find no deviations from General Relativity insofar as the signal path and the perturbing mass reside in a screened region of space.

  3. Blinded Validation of Breath Biomarkers of Lung Cancer, a Potential Ancillary to Chest CT Screening

    PubMed Central

    Phillips, Michael; Bauer, Thomas L.; Cataneo, Renee N.; Lebauer, Cassie; Mundada, Mayur; Pass, Harvey I.; Ramakrishna, Naren; Rom, William N.; Vallières, Eric

    2015-01-01

    Background Breath volatile organic compounds (VOCs) have been reported as biomarkers of lung cancer, but it is not known if biomarkers identified in one group can identify disease in a separate independent cohort. Also, it is not known if combining breath biomarkers with chest CT has the potential to improve the sensitivity and specificity of lung cancer screening. Methods Model-building phase (unblinded): Breath VOCs were analyzed with gas chromatography mass spectrometry in 82 asymptomatic smokers having screening chest CT, 84 symptomatic high-risk subjects with a tissue diagnosis, 100 without a tissue diagnosis, and 35 healthy subjects. Multiple Monte Carlo simulations identified breath VOC mass ions with greater than random diagnostic accuracy for lung cancer, and these were combined in a multivariate predictive algorithm. Model-testing phase (blinded validation): We analyzed breath VOCs in an independent cohort of similar subjects (n = 70, 51, 75 and 19 respectively). The algorithm predicted discriminant function (DF) values in blinded replicate breath VOC samples analyzed independently at two laboratories (A and B). Outcome modeling: We modeled the expected effects of combining breath biomarkers with chest CT on the sensitivity and specificity of lung cancer screening. Results Unblinded model-building phase. The algorithm identified lung cancer with sensitivity 74.0%, specificity 70.7% and C-statistic 0.78. Blinded model-testing phase: The algorithm identified lung cancer at Laboratory A with sensitivity 68.0%, specificity 68.4%, C-statistic 0.71; and at Laboratory B with sensitivity 70.1%, specificity 68.0%, C-statistic 0.70, with linear correlation between replicates (r = 0.88). In a projected outcome model, breath biomarkers increased the sensitivity, specificity, and positive and negative predictive values of chest CT for lung cancer when the tests were combined in series or parallel. Conclusions Breath VOC mass ion biomarkers identified lung cancer in a separate independent cohort, in a blinded replicated study. Combining breath biomarkers with chest CT could potentially improve the sensitivity and specificity of lung cancer screening. Trial Registration ClinicalTrials.gov NCT00639067 PMID:26698306

  4. Mass Media Campaign Improves Cervical Screening across All Socio-Economic Groups

    ERIC Educational Resources Information Center

    Anderson, Jenny O.; Mullins, Robyn M.; Siahpush, Mohammad; Spittal, Matthew J.; Wakefield, Melanie

    2009-01-01

    Low socio-economic status (SES) has been associated with lower cervical screening rates. Mass media is one known strategy that can increase cervical screening participation. This study sought to determine whether a mass media campaign conducted in Victoria, Australia, in 2005 was effective in encouraging women across all SES groups to screen. Data…

  5. Context-dependent effects of background colour in free recall with spatially grouped words.

    PubMed

    Sakai, Tetsuya; Isarida, Toshiko K; Isarida, Takeo

    2010-10-01

    Three experiments investigated context-dependent effects of background colour in free recall with groups of items. Undergraduates (N=113) intentionally studied 24 words presented in blocks of 6 on a computer screen with two different background colours. The two background colours were changed screen-by-screen randomly (random condition) or alternately (alternation condition) during the study period. A 30-second filled retention interval was imposed before an oral free-recall test. A signal for free recall was presented throughout the test on one of the colour background screens presented at study. Recalled words were classified as same- or different-context words according to whether the background colours at study and test were the same or different. The random condition produced significant context-dependent effects, whereas the alternation condition showed no context-dependent effects, regardless of whether the words were presented once or twice. Furthermore, the words presented on the same screen were clustered in recall, whereas the words presented against the same background colour but on different screens were not clustered. The present results imply: (1) background colours can cue spatially massed words; (2) background colours act as temporally local context; and (3) predictability of the next background colour modulates the context-dependent effect.

  6. [Application of precursor ion scanning method in rapid screening of illegally added phosphodiesterase-5 inhibitors and their unknown derivatives in Chinese traditional patent medicines and health foods].

    PubMed

    Sun, Jing; Cao, Ling; Feng, Youlong; Tan, Li

    2014-11-01

    The compounds with similar structure often have similar pharmacological activities. So it is a trend for illegal addition that new derivatives of effective drugs are synthesized to avoid the statutory test. This bring challenges to crack down on illegal addition behavior, however, modified derivatives usually have similar product ions, which allow for precursor ion scanning. In this work, precursor ion scanning mode of a triple quadrupole mass spectrometer was first applied to screen illegally added drugs in complex matrix such as Chinese traditional patent medicines and healthy foods. Phosphodiesterase-5 inhibitors were used as experimental examples. Through the analysis of the structure and mass spectrum characteristics of the compounds, phosphodiesterase-5 inhibitors were classified, and their common product ions were screened by full scan of product ions of typical compounds. Then high performance liquid chromatography-tandem mass spectrometry (HPLC-MS/MS) method with precursor ion scanning mode was established based on the optimization of MS parameters. The effect of mass parameters and the choice of fragment ions were also studied. The method was applied to determine actual samples and further refined. The results demonstrated that this method can meet the need of rapid screening of unknown derivatives of phosphodiesterase-5 inhibitors in complex matrix, and prevent unknown derivatives undetected. This method shows advantages in sensitivity, specificity and efficiency, and is worth to be further investigated.

  7. Multiplex tandem mass spectrometry assay for newborn screening of X-linked adrenoleukodystrophy, biotinidase deficiency, and galactosemia with flexibility to assay other enzyme assays and biomarkers.

    PubMed

    Hong, Xinying; Kumar, Arun Babu; Ronald Scott, C; Gelb, Michael H

    2018-03-29

    All States screen for biotinidase deficiency and galactosemia, and X-linked adrenoleukodystrophy (X-ALD) has recently been added to the Recommended Uniform Screening Panel (RUSP).We sought to consolidate these tests by combining them into a single multiplex tandem mass spectrometry assay as well as to improve the current protocol for newborn screening of galactosemia.A 3 mm punch of a dried blood spot (DBS) was extracted with organic solvent for analysis of the C26:0-lysophosphatidylcholine biomarker for X-ALD.An additional punch was used to assay galactose-1-phosphate uridyltransferase (GALT) and biotinidase.All assays were combined for a single injection for analysis by liquid chromatography-tandem mass spectrometry (LC-MS/MS) (2.3 min per sample).The GALT LC-MS/MS assay does not give a false positive for galactosemia if glucose-6-phosphate dehydrogenase is deficient.The multiplex assay shows acceptable reproducibility and provides for rapid analysis of X-ALD, biotinidase deficiency, and galactosemia.The throughput and ease of sample preparation are acceptable for newborn screening laboratories.We also show that the LC-MS/MS assay is expandable to include several other diseases including Pompe and Hurler diseases (enzymatic activities and biomarkers).Because of consolidation of assays, less manpower is needed compared to running individual assays on separate platforms.The flexibility of the LC-MS/MS platform allows each newborn screening laboratory to analyze the set of diseases offered in their panel. Copyright © 2018 Elsevier Inc. All rights reserved.

  8. Value of cytopathologist-performed ultrasound-guided fine-needle aspiration as a screening test for ultrasound-guided core-needle biopsy in nonpalpable breast masses.

    PubMed

    Lieu, David

    2009-04-01

    Fine-needle aspiration (FNA) of breast masses in the United States has been on the decline for the last decade and has been largely replaced by ultrasound-guided core-needle biopsy (UG-CNB). Some studies show core-needle biopsy (CNB) is superior to FNA in terms of absolute sensitivity, specificity, and inadequate rate. However, the importance of a skilled aspirator, experienced cytopathologist, and immediate cytological evaluation (ICE) in FNA is often not considered. CNB is more expensive, invasive, risky, and painful than FNA. This prospective study examines the value of cytopathologist-performed ultrasound-guided FNA (UG-FNA) with ICE as a screening test for cytopathologist-performed UG-CNB on nonpalpable or difficult-to-palpate solid breast masses visible on ultrasound. One hundred twenty consecutive nonpalpable or difficult-to-palpate presumably solid breast masses in 109 female patients from January2, 2008 to June 30, 2008 underwent cytopathologist-performed UG-FNA with ICE. Twenty cases were converted to cytopathologist-performed UG-CNB because ICE was inadequate, hypocellular, atypical, suspicious, or malignant. Patients with clearly benign cytology did not undergo UG-CNB. UG-FNA with ICE reduced the percentage of patients undergoing UG-CNB by 87%. A new role for cytopathologist-performed UG-FNA of nonpalpable breast masses has been identified.

  9. Rapid Screening and Characterization of Acetylcholinesterase Inhibitors from Yinhuang Oral Liquid Using Ultrafiltration-liquid Chromatography-electrospray Ionization Tandem Mass Spectrometry

    PubMed Central

    Zhang, Haomin; Guo, Yinan; Meng, Lingwen; Sun, Hui; Yang, Yinping; Gao, Ying; Sun, Jiaming

    2018-01-01

    Background: At present, approximately 17–25 million people in the world suffer from Alzheimer's disease (AD). The most efficacious and acceptable therapeutic drug clinically are the acetylcholinesterase inhibitors (AChEIs). Yinhuang oral liquid is a Chinese medicine preparation which contains AChEIs according to the literatures. However, no strategy has been presented for rapid screening and identification of AChEIs from Yinhuang oral liquid. Objective: To develop a method for rapid screening and identification of AChEIs from Yinhuang oral liquid using ultrafiltration–liquid chromatography–electrospray ionization tandem mass spectrometry (UF-LC-ESI-MS/MS). Materials and Methods: In this study, UF incubation conditions such as enzyme concentration, incubation time, and incubation temperature were optimized so as to get better screening results. The AChEIs from Yinhuang oral liquid were identified by high-performance liquid chromatography-ESI-MS and the improved Ellman method was used for the AChE inhibitory activity test in vitro. Results: The results showed that Yinhuang oral liquid can inhibit the activity of AChE. We screened and identified seven compounds with potential AChE inhibitory activity from Yinhuang oral liquid, which provided experimental basis for the treatment and prevention of AD. Conclusion: The current technique was used to directly screen the active ingredients with acetylcholinesterase inhibition from complex traditional Chinese medicine, which was simple, rapid, accurate, and suitable for high-throughput screening of AChEI from complex systems. SUMMARY A UF-LC-ESI-MS/MS method for rapid screening and identification of AChEIs from Yinhuang oral liquid was developedSeven compounds were screened and identified with potential AChE inhibitory activity from Yinhuang oral liquidIt provided experimental basis of Yinhuang oral liquid for the treating and preventing AD. Abbreviations used: (AD): Alzheimer's disease; (UF-LC-ESI-MS/MS): ultrafiltration–liquid chromatography–electrospray ionization tandem mass spectrometry; (AChEIs): acetylcholinesterase inhibitors. PMID:29720840

  10. SINGLE-INTERVAL GAS PERMEABILITY ESTIMATION

    EPA Science Inventory

    Single-interval, steady-steady-state gas permeability testing requires estimation of pressure at a screened interval which in turn requires measurement of friction factors as a function of mass flow rate. Friction factors can be obtained by injecting air through a length of pipe...

  11. Increasing Sustained Participation in Free Mass Prostate Cancer Screening Clinics

    DTIC Science & Technology

    2006-05-01

    Oncology. 1998; 16: 187-192 6. Myers RE, Hyslop T, Wolf TA, Burgh D, Kunkel EJS, Oyesanmi O, Chodak GJ. African American Men and Intention to Adhere to...Price, M.M. ( 1980 ). Critique of the Milani-Comparetti Motor Development Screening Test. Physical And Occupational Therapy In Pediatrics, 1 (1...Medscape. 2. Non-refereed publications: 1. Price, M.M. ( 1980 ). Why do they suck their thumbs? Baby Talk, 46 (5), 28-29. 2. Price, M.M. (1982

  12. Analyzing slug tests in wells screened across the watertable: A field assessment

    USGS Publications Warehouse

    Stanford, K.L.; McElwee, C.D.

    2000-01-01

    The slug test is the most widely used technique for the in situ estimation of hydraulic conductivity in confined and unconfined formations. Currently, there are no generally accepted methods in the groundwater literature for the analysis of response data from slug tests performed in wells screened across the watertable. A field study was undertaken in an attempt to develop a set of practical guidelines for tests conducted in such wells. Three wells, screened within unconsolidated material exhibiting a range of hydraulic conductivities (.05-30.0 m/day), were installed to depths of up to 9 m (30 ft) in Kansas River alluvium that ranges in thickness from 15 m to 21 m (50 ft to 70 ft) near Lawrence, Kansas. Intensive well-development efforts removed any drilling debris that could interfere with well-formation hydraulics. Once the wells were developed properly, a series of slug tests was performed at each well. The tests were designed to assess the role of the unsaturated zone and the appropriateness of assuming a fixed hydraulic head upper boundary. The results of this investigation can be summarized as follows: (1) the sufficiency of well development should be based on repeat slug tests and not the clarity of pumped water; (2) the effective screen radius for best model analysis should be based on a mass balance and not nominal screen dimensions; (3) the watertable can be represented as a constant head boundary and flow in the unsaturated zone can be ignored in most situations; (4) conventional techniques for the analysis of slug-test data seem to be reasonable for slug tests conducted in wells screened across the watertable, when used with the appropriate effective screen radius and normalized head range; and (5) fluctuations in the watertable elevation through time can be exploited to obtain some insight into the nature of vertical variation in hydraulic conductivity at a well. The results of this investigation indicate that multiple slug tests should be performed at wells screened across the watertable in order to reliably assess the sufficiency of well development and the appropriateness of conventional theory. ?? 2000 International Association for Mathematical Geology.

  13. Newborn screening for lysosomal storage disorders by tandem mass spectrometry in North East Italy.

    PubMed

    Burlina, Alberto B; Polo, Giulia; Salviati, Leonardo; Duro, Giovanni; Zizzo, Carmela; Dardis, Andrea; Bembi, Bruno; Cazzorla, Chiara; Rubert, Laura; Zordan, Roberta; Desnick, Robert J; Burlina, Alessandro P

    2018-03-01

    Lysosomal storage diseases (LSDs) are inborn errors of metabolism resulting from 50 different inherited disorders. The increasing availability of treatments and the importance of early intervention have stimulated newborn screening (NBS) to diagnose LSDs and permit early intervention to prevent irreversible impairment or severe disability. We present our experience screening newborns in North East Italy to identify neonates with Mucopolysaccharidosis type I (MPS I) and Pompe, Fabry, and Gaucher diseases. Activities of acid β-glucocerebrosidase (ABG; Gaucher), acid α-glucosidase (GAA; Pompe), acid α-galactosidase (GLA; Fabry), and acid α-L-iduronidase (IDUA; MPS-I) in dried blood spots (DBS) from all newborns during a 17-month period were determined by multiplexed tandem mass spectrometry (MS/MS) using the NeoLSD ® assay system. Enzymatic activity cutoff values were determined from 3500 anonymous newborn DBS. In the screening study, samples were retested if the value was below cutoff and a second spot was requested, with referral for confirmatory testing and medical evaluation if a low value was obtained. From September 2015 to January 2017, 44,411 newborns were screened for the four LSDs. We recalled 40 neonates (0.09%) for collection of a second DBS. Low activity was confirmed in 20, who had confirmatory testing. Ten of 20 had pathogenic mutations: two Pompe, two Gaucher, five Fabry, and one MPS-I. The incidences of Pompe and Gaucher diseases were similar (1/22,205), with Fabry disease the most frequent (1/8882) and MPS-I the rarest (1/44411). The combined incidence of the four disorders was 1/4411 births. Simultaneously determining multiple enzyme activities by MS/MS, with a focus on specific biochemical markers, successfully detected newborns with LSDs. The high incidence of these disorders supports this screening program.

  14. Guidelines for Mass Screening of Congenital Hypothyroidism (2014 revision)

    PubMed Central

    Nagasaki, Keisuke; Minamitani, Kanshi; Anzo, Makoto; Adachi, Masanori; Ishii, Tomohiro; Onigata, Kazumichi; Kusuda, Satoshi; Harada, Shohei; Horikawa, Reiko; Minagawa, Masanori; Mizuno, Haruo; Yamakami, Yuji; Fukushi, Masaru; Tajima, Toshihiro

    2015-01-01

    Purpose of developing the guidelines: Mass screening for congenital hypothyroidism started in 1979 in Japan, and the prognosis for intelligence has been improved by early diagnosis and treatment. The incidence was about 1/4000 of the birth population, but it has increased due to diagnosis of subclinical congenital hypothyroidism. The disease requires continuous treatment, and specialized medical facilities should make a differential diagnosis and treat subjects who are positive in mass screening to avoid unnecessary treatment. The Guidelines for Mass Screening of Congenital Hypothyroidism (1998 version) were developed by the Mass Screening Committee of the Japanese Society for Pediatric Endocrinology in 1998. Subsequently, new findings on prognosis and problems in the adult phase have emerged. Based on these new findings, the 1998 guidelines were revised in the current document (hereinafter referred to as the Guidelines). Target disease/conditions: Primary congenital hypothyroidism. Users of the Guidelines: Physician specialists in pediatric endocrinology, pediatric specialists, physicians referring patients to pediatric practitioners, general physicians, laboratory technicians in charge of mass screening, and patients. PMID:26594093

  15. Anthropometric Variables Accurately Predict Dual Energy X-Ray Absorptiometric-Derived Body Composition and Can Be Used to Screen for Diabetes

    PubMed Central

    Yavari, Reza; McEntee, Erin; McEntee, Michael; Brines, Michael

    2011-01-01

    The current world-wide epidemic of obesity has stimulated interest in developing simple screening methods to identify individuals with undiagnosed diabetes mellitus type 2 (DM2) or metabolic syndrome (MS). Prior work utilizing body composition obtained by sophisticated technology has shown that the ratio of abdominal fat to total fat is a good predictor for DM2 or MS. The goals of this study were to determine how well simple anthropometric variables predict the fat mass distribution as determined by dual energy x-ray absorptometry (DXA), and whether these are useful to screen for DM2 or MS within a population. To accomplish this, the body composition of 341 females spanning a wide range of body mass indices and with a 23% prevalence of DM2 and MS was determined using DXA. Stepwise linear regression models incorporating age, weight, height, waistline, and hipline predicted DXA body composition (i.e., fat mass, trunk fat, fat free mass, and total mass) with good accuracy. Using body composition as independent variables, nominal logistic regression was then performed to estimate the probability of DM2. The results show good discrimination with the receiver operating characteristic (ROC) having an area under the curve (AUC) of 0.78. The anthropometrically-derived body composition equations derived from the full DXA study group were then applied to a group of 1153 female patients selected from a general endocrinology practice. Similar to the smaller study group, the ROC from logistical regression using body composition had an AUC of 0.81 for the detection of DM2. These results are superior to screening based on questionnaires and compare favorably with published data derived from invasive testing, e.g., hemoglobin A1c. This anthropometric approach offers promise for the development of simple, inexpensive, non-invasive screening to identify individuals with metabolic dysfunction within large populations. PMID:21915276

  16. Case study to illustrate an approach for detecting contamination and impurities in pesticide formulations.

    PubMed

    Karasali, Helen; Kasiotis, Konstantinos M; Machera, Kyriaki; Ambrus, Arpad

    2014-11-26

    Counterfeit pesticides threaten public health, food trade, and the environment. The present work draws attention to the importance of regular monitoring of impurities in formulated pesticide products. General screening revealed the presence of carbaryl as a contaminant in a copper oxychloride formulated product. In this paper, as a case study, a liquid chromatographic diode array-mass spectrometric method developed for general screening of pesticide products and quantitative determination of carbaryl together with its validation is presented. The proposed testing strategy is considered suitable for use as a general approach for testing organic contaminants and impurities in solid pesticide formulations.

  17. Mapping HL7 CDA R2 Formatted Mass Screening Data to OpenEHR Archetypes.

    PubMed

    Kobayashi, Shinji; Kume, Naoto; Yoshihara, Hiroyuki

    2017-01-01

    Mass screening of adults was performed to manage employee healthcare. The screening service defined the data collection format as HL7 Clinical Document Architecture (CDA) R2. To capture mass screening data for nationwide electronic health records (her), we programmed a model within the CDA format and mapped the data items to the ISO13606/openEHR archetype for semantic interoperabiilty.

  18. Lifestyle predictors for non-participation and outcome in the second round of faecal immunochemical test in colorectal cancer screening.

    PubMed

    Knudsen, Markus Dines; Berstad, Paula; Hjartåker, Anette; Gulichsen, Elisabeth Haagensen; Hoff, Geir; de Lange, Thomas; Bernklev, Tomm; Botteri, Edoardo

    2017-08-08

    To reduce colorectal cancer (CRC) mortality through population-based screening programmes using faecal tests, it is important that individuals continue to participate in the repeated rounds of screening. We aimed to identify lifestyle predictors for discontinuation of faecal immunochemical test (FIT) screening after the first round, as well as lifestyle predictors for colorectal neoplasia detected in the second-round FIT screening. In this longitudinal study, we invited 6959 individuals aged 50-74 years from south-east Norway for a first round of FIT screening and to complete a self-reported lifestyle questionnaire on demographic factors, body mass index (BMI, kg m -2 ), smoking habits, physical activity, consumption of alcohol and dietary items. Two years later, we estimated the associations between these factors, non-participation and screening results in the second round of FIT screening using adjusted odds ratios (ORs) and 95% confidence intervals (CIs). Of the 3114 responders to the questionnaire who completed the first-round FIT and who were invited to participate in second-round FIT screening, 540 (17%) did not participate. The OR and (95% CI) for discontinuation of FIT screening after the first round was 1.61 (1.24-2.10) for current smoking compared with non-smoking; 2.01 (1.25-3.24) for BMI⩾35 kg m -2 compared with BMI 16.9-24.9 kg m -2 and 0.70 (0.52-0.94) for physical activity in the third quartile vs the first. Among participants, smoking, high BMI and high alcohol consumption were associated with an increased odds of detecting colorectal neoplasia (n=107). These results may indicate that Norwegian FIT screening participants who discontinue after the first round have lifestyle behaviours associated with increased risk of CRC.

  19. Mass spectrometry in clinical chemistry: the case of newborn screening.

    PubMed

    la Marca, Giancarlo

    2014-12-01

    Newborn screening (NBS) program is a complex and organized system consisting of family and personnel education, biochemical tests, confirmatory biochemical and genetic tests, diagnosis, therapy, and patient follow up. The program identifies treatable metabolic disorders possibly when asymptomatic by using dried blood spot (DBS). During the last 20 years tandem mass spectrometry (TMS) has become the leading technology in NBS programs demonstrating to be versatile, sensitive and specific. There is consistent evidence of benefits from NBS for many disorders detected by TMS as well as for congenital hypothyroidism, cystic fibrosis, congenital adrenal hyperplasia by immune-enzymatic methods. Real time PCR tests have more recently been proposed for the detection of some severe combined immunodeficiences (SCID) along with the use of TMS for ADA and PNP SCID; a first evaluation of their cost-benefit ratio is still ongoing. Avoiding false negative results by using specific biomarkers and reducing the false positive rate by using second tier tests, is fundamental for a successful NBS program. The fully integration of NBS and diagnostic laboratories with clinical service is crucial to have the best effectiveness in a comprehensive NBS system. Copyright © 2014 Elsevier B.V. All rights reserved.

  20. Population screening for colorectal cancer by flexible sigmoidoscopy or CT colonography: study protocol for a multicenter randomized trial

    PubMed Central

    2014-01-01

    Background Colorectal cancer (CRC) is the second most prevalent type of cancer in Europe. A single flexible sigmoidoscopy (FS) screening at around the age of 60 years prevents about one-third of CRC cases. However, FS screens only the distal colon, and thus mortality from proximal CRC is unaffected. Computed tomography colonography (CTC) is a highly accurate examination that allows assessment of the entire colon. However, the benefit of CTC testing as a CRC screening test is uncertain. We designed a randomized trial to compare participation rate, detection rates, and costs between CTC (with computer-aided detection) and FS as primary tests for population-based screening. Methods/Design An invitation letter to participate in a randomized screening trial comparing CTC versus FS will be mailed to a sample of 20,000 people aged 58 or 60 years, living in the Piedmont region and the Verona district of Italy. Individuals with a history of CRC, adenomas, inflammatory bowel disease, or recent colonoscopy, or with two first-degree relatives with CRC will be excluded from the study by their general practitioners. Individuals responding positively to the invitation letter will be then randomized to the intervention group (CTC) or control group (FS), and scheduled for the screening procedure. The primary outcome parameter of this part of the trial is the difference in advanced neoplasia detection between the two screening tests. Secondary outcomes are cost-effectiveness analysis, referral rates for colonoscopy induced by CTC versus FS, and the expected and perceived burden of the procedures. To compare participation rates for CTC versus FS, 2,000 additional eligible subjects will be randomly assigned to receive an invitation for screening with CTC or FS. In the CTC arm, non-responders will be offered fecal occult blood test (FOBT) as alternative screening test, while in the FS arm, non-responders will receive an invitation letter to undergo screening with either FOBT or CTC. Data on reasons for participation and non-participation will also be collected. Discussion This study will provide reliable information concerning benefits and risks of the adoption of CTC as a mass screening intervention in comparison with FS. The trial will also evaluate the role of computer-aided detection in a screening setting. Trial registration ClinicalTrials.gov Identifier: NCT01739608 PMID:24678896

  1. The clinical impact of a false-positive urine cocaine screening result on a patient's pain management.

    PubMed

    Kim, James A; Ptolemy, Adam S; Melanson, Stacy E F; Janfaza, David R; Ross, Edgar L

    2015-06-01

    The urine of a patient admitted for chest and epigastric pain tested positive for cocaine using an immunoassay-based drug screening method (positive/negative cutoff concentration 150 ng/mL). Despite the patient's denial of recent cocaine use, this positive cocaine screening result in conjunction with a remote history of drug misuse impacted the patient's recommended pain therapy. Specifically, these factors prompted the clinical team to question the appropriateness of opioids and other potentially addictive therapeutics during the treatment of cancer pain from previously undetected advanced pancreatic carcinoma. After pain management and clinical pathology consultation, it was decided that the positive cocaine screening result should be confirmed by gas chromatography-mass spectrometry (GC-MS) testing. This more sensitive and specific analytical technique revealed that both cocaine and its primary metabolite benzoylecgonine were undetectable (i.e., less than the assay detection limit of 50 ng/mL), thus indicating that the positive urine screening result was falsely positive. With this confirmation, the pain management service team was reassured in offering intrathecal pump (ITP) therapy for pain control. ITP implantation was well tolerated, and the patient eventually achieved excellent pain relief. However, ITP therapy most likely would not have been utilized without the GC-MS confirmation testing unless alternative options failed and extensive vigilant monitoring was initiated. As exemplified in this case, confirmatory drug testing should be performed on specimens with unexpected immunoassay-based drug screening results. To our knowledge, this is the first report of a false-positive urine cocaine screening result and its impact on patient management. Wiley Periodicals, Inc.

  2. Digital Image Processing Technique for Breast Cancer Detection

    NASA Astrophysics Data System (ADS)

    Guzmán-Cabrera, R.; Guzmán-Sepúlveda, J. R.; Torres-Cisneros, M.; May-Arrioja, D. A.; Ruiz-Pinales, J.; Ibarra-Manzano, O. G.; Aviña-Cervantes, G.; Parada, A. González

    2013-09-01

    Breast cancer is the most common cause of death in women and the second leading cause of cancer deaths worldwide. Primary prevention in the early stages of the disease becomes complex as the causes remain almost unknown. However, some typical signatures of this disease, such as masses and microcalcifications appearing on mammograms, can be used to improve early diagnostic techniques, which is critical for women’s quality of life. X-ray mammography is the main test used for screening and early diagnosis, and its analysis and processing are the keys to improving breast cancer prognosis. As masses and benign glandular tissue typically appear with low contrast and often very blurred, several computer-aided diagnosis schemes have been developed to support radiologists and internists in their diagnosis. In this article, an approach is proposed to effectively analyze digital mammograms based on texture segmentation for the detection of early stage tumors. The proposed algorithm was tested over several images taken from the digital database for screening mammography for cancer research and diagnosis, and it was found to be absolutely suitable to distinguish masses and microcalcifications from the background tissue using morphological operators and then extract them through machine learning techniques and a clustering algorithm for intensity-based segmentation.

  3. Estimating Hyrdologic Properties of Groundwater Wells Using Tracer Pulse Dynamic Flow Profiling

    NASA Astrophysics Data System (ADS)

    Miles, K. A.; Heller, N.

    2016-12-01

    Traditional groundwater well design places the pump intake above the top of the well screen. It is common in this case to design the well screen for uniform entrance velocity along the profile of the well screen, even though non-uniform flow may occur. Particularly in the case where the pump is set near the very top or bottom of the well, there are instances where the zonal testing with a test pump indicates favorable water quality at one pump depth of the groundwater production well, and the water quality results yielded from the well at another depth are not compliant with federal and state regulatory limits for various naturally occurring and anthropogenic compounds. Well bore flow velocity and chemistry were determined using the USGS Tracer Pulse Dynamic Flow Profiling method along the length of well screens, while varying the pump depth. The information was then used to perform a flow and chemical mass balance to characterize the distribution of flow and chemical contribution, groundwater well screen entrance velocities, and hydrologic parameters. The presented results show pump placement affecting the average chemical discharge, and entrance velocities along the length of well screens.

  4. The Infrared Automatic Mass Screening (IRAMS) System For Printed Circuit Board Fault Detection

    NASA Astrophysics Data System (ADS)

    Hugo, Perry W.

    1987-05-01

    Office of the Program Manager for TMDE (OPM TMDE) has initiated a program to develop techniques for evaluating the performance of printed circuit boards (PCB's) using infrared thermal imaging. It is OPM TMDE's expectation that the standard thermal profile (STP) will become the basis for the future rapid automatic detection and isolation of gross failure mechanisms on units under test (UUT's). To accomplish this OPM TMDE has purchased two Infrared Automatic Mass Screening ( I RAMS) systems which are scheduled for delivery in 1987. The IRAMS system combines a high resolution infrared thermal imager with a test bench and diagnostic computer hardware and software. Its purpose is to rapidly and automatically compare the thermal profiles of a UUT with the STP of that unit, recalled from memory, in order to detect thermally responsive failure mechanisms in PCB's. This paper will review the IRAMS performance requirements, outline the plan for implementing the two systems and report on progress to date.

  5. Operational Art and the Incident Command System: Public Health’s Bridge in Bioterrorism Preparedness and Response

    DTIC Science & Technology

    2003-03-22

    e.g., tuberculosis screening or a maximal treadmill test ); and 3) tertiary prevention limits disability and rehabilitation where the disease or injury...major city/county laboratories to develop the capacity to conduct rapid and accurate diagnostic and reference testing for select biologic agents likely...system, but it has not been thoroughly tested and coordinated in the civilian sector. The association of mass casualty care with hospital

  6. Non-invasive prenatal testing for fetal chromosome abnormalities: review of clinical and ethical issues

    PubMed Central

    Gekas, Jean; Langlois, Sylvie; Ravitsky, Vardit; Audibert, François; van den Berg, David Gradus; Haidar, Hazar; Rousseau, François

    2016-01-01

    Genomics-based non-invasive prenatal screening using cell-free DNA (cfDNA screening) was proposed to reduce the number of invasive procedures in current prenatal diagnosis for fetal aneuploidies. We review here the clinical and ethical issues of cfDNA screening. To date, it is not clear how cfDNA screening is going to impact the performances of clinical prenatal diagnosis and how it could be incorporated in real life. The direct marketing to users may have facilitated the early introduction of cfDNA screening into clinical practice despite limited evidence-based independent research data supporting this rapid shift. There is a need to address the most important ethical, legal, and social issues before its implementation in a mass setting. Its introduction might worsen current tendencies to neglect the reproductive autonomy of pregnant women. PMID:26893576

  7. Non-invasive prenatal testing for fetal chromosome abnormalities: review of clinical and ethical issues.

    PubMed

    Gekas, Jean; Langlois, Sylvie; Ravitsky, Vardit; Audibert, François; van den Berg, David Gradus; Haidar, Hazar; Rousseau, François

    2016-01-01

    Genomics-based non-invasive prenatal screening using cell-free DNA (cfDNA screening) was proposed to reduce the number of invasive procedures in current prenatal diagnosis for fetal aneuploidies. We review here the clinical and ethical issues of cfDNA screening. To date, it is not clear how cfDNA screening is going to impact the performances of clinical prenatal diagnosis and how it could be incorporated in real life. The direct marketing to users may have facilitated the early introduction of cfDNA screening into clinical practice despite limited evidence-based independent research data supporting this rapid shift. There is a need to address the most important ethical, legal, and social issues before its implementation in a mass setting. Its introduction might worsen current tendencies to neglect the reproductive autonomy of pregnant women.

  8. [Interval cancers and episode sensitivity in population-based screening programmes for colorectal cancer: a systematic review].

    PubMed

    Domènech, Xènia; Garcia, Montse; Benito, Llúcia; Binefa, Gemma; Vidal, Carmen; Milà, Núria; Moreno, Víctor

    2015-01-01

    To describe interval cancers (IC) and the sensitivity of colorectal cancer (CRC) screening programmes. A systematic review of the literature was conducted through a MEDLINE (PubMed) search. The search strategy combined the terms 'interval cancer', 'false negative', 'mass screening', 'screening' 'early detection of cancer', 'colorectal cancer' and 'bowel cancer'. Inclusion criteria consisted of population-based screening programmes, original articles written in English or Spanish and publication dates between 1999/01/01 and 2015/02/28. A narrative synthesis of the included articles was performed detailing the characteristics of the screening programmes, the IC rate, and the information sources used in each study. Thirteen articles were included. The episode sensitivity of CRC screening programmes ranged from 42.2% to 65.3% in programmes using the guaiac test and between 59.1% and 87.0% with the immunochemical test. We found a higher proportion of women who were diagnosed with IC and these lesions were mainly located in the proximal colon. There is wide variability in the IC rate in CRC programmes. To ensure comparability between programmes, there is a need for consensus on the working definition of IC and the methods used for their identification and quantification. Copyright © 2014 SESPAS. Published by Elsevier Espana. All rights reserved.

  9. [Evaluation of physical development of children with congenital hypothyroidism detected in the screening test--personal observations].

    PubMed

    Kik, Eugenia; Noczyńska, Anna

    2011-01-01

    Congenital hypothyroidism (CH) is the most prevalent endocrinopathy resulting from thyroid hormones deficiency or lack of thyroid hormones (TH). Aim of the study is to evaluate the physical development of children with congenital hypothyroidism detected in screening tests, determine the effect of TSH level, thyroid hormones and perinatal, parental and environmental factors on the physical development of children. the study involved 79 children (47 girls, 32 boys) aged 3-18 years (mean age 7.3±3.5) with CH diagnosed in screening tests. Children's development was analysed in correlation with TSH value in the screening test, time of commencement of therapy with LT4, the initial dose of the LT4, mean TSH level in the first year of life, mean value of TSH and LT4 in the 2-year follow-up period, social origin, place of residence (village, city), parents': anthropometric parameters (BMI, height), age, level of education of the parents, which pregnancy it was, time of pregnancy. In children: body mass and length at birth, score on Apgar scale, additional chronic disease. Too low body mass was usually observed in the 2-4 month of life - 11.1%, while in the following months, the number of children with body mass below the 3 centile became lower. In children diagnosed with too low body mass <18 month of life, in the subsequent months was observed a normalisation. No correlation was between the body mass and TSH in infancy, the place of residence and level of education of the parents in all examined groups. According to Palczewska, BMI >97 centile occurred more often in the group of children with CH in the age range of 11 months - 6.9 years than in the control group, whereas ≥7 years obesity did not occur. The number of children with insufficient body length increased in the age groups: 11-18 months - 7.4%; 1.6-3.9 years - 7.9 % and 4-6.9 years - 9.1%. Children ≥7 years with height <3 centile were not observed. The number of children with height >97 centile in three age groups did not go beyond 4%. The biggest number of children >97 centile was noted in the age group 1.6-3.9 years (7.9%). Mean height SDS in all age groups was within the norm (±1 SDS for healthy population). 1. Physical development of children in infancy was in normal range. 2. Mean SDS of body mass in children was in the range of 1sds for healthy population in each age quarter. 3. Mean SDS for BMI in all age groups was above zero. 4. Mean SDS for body length in all age groups was in the range ±1 SDS for healthy population. 5. Early initiation of therapy HT is a prerequisite for proper physical development of children with congenital hypothyroidism.

  10. 1-Adamantylamine a simple urine marker for screening for third generation adamantyl-type synthetic cannabinoids by ultra-performance liquid chromatography tandem mass spectrometry.

    PubMed

    Ford, Loretta T; Berg, Jonathan D

    2016-11-01

    Background Synthetic cannabinoids (NOIDS) are novel psychotropic drugs (NPS) currently freely sold in the United Kingdom as 'research chemicals'. Detection of NOIDS use is not available in current routine methods. Here we describe a marker which helps determine which patients have used these substances. Methods In a test case, ultra-performance liquid chromatography mass spectrometry (UPLC-Tof) was used to screen the legal high Herbal Haze II, the contents of hand-rolled cigarettes and five patient samples for NOIDS and their metabolites. Results Analysis of legal high Herbal Haze II and cigarettes identified the third generation adamantyl-type NOIDS N-(1-adamantyl)-1-pentyl-1H-indazole-3-carboxamide (AKB-48), 5F-AKB-48 and N-adamantyl-1-fluoropentylindole-3-carboxamide (STS-135). Out of 18 potential metabolites, 1-adamantylamine (C 10 H 17 N) was detected in all five urine samples. This adamantyl-type NOID marker was incorporated into our routine LC-MS/MS urine screen. Out of 14,436 random urine samples screened over eight months, 296 (2.05%) tested positive for the adamantyl-type NOID marker. Conclusion We have discovered a urine marker for identifying patients smoking legal high products containing the third generation adamantyl-type NOIDS such as AKB-48 and its fluoropentyl analogue 5F-AKB-48, which are among the most popular NOIDS currently available in legal high products sold in UK. This marker can be incorporated into routine LC-MS/MS drug screening alongside classic drugs of abuse. Positive detection rates for this new legal high marker are greater than for established classic drugs that are routinely screened such as amphetamine. This work highlights the need for a flexible toxicology screening service capable of adapting to changes in drug use such as the growing popularity of legal highs/NPS.

  11. Fully automated screening of veterinary drugs in milk by turbulent flow chromatography and tandem mass spectrometry

    PubMed Central

    Stolker, Alida A. M.; Peters, Ruud J. B.; Zuiderent, Richard; DiBussolo, Joseph M.

    2010-01-01

    There is an increasing interest in screening methods for quick and sensitive analysis of various classes of veterinary drugs with limited sample pre-treatment. Turbulent flow chromatography in combination with tandem mass spectrometry has been applied for the first time as an efficient screening method in routine analysis of milk samples. Eight veterinary drugs, belonging to seven different classes were selected for this study. After developing and optimising the method, parameters such as linearity, repeatability, matrix effects and carry-over were studied. The screening method was then tested in the routine analysis of 12 raw milk samples. Even without internal standards, the linearity of the method was found to be good in the concentration range of 50 to 500 µg/L. Regarding repeatability, RSDs below 12% were obtained for all analytes, with only a few exceptions. The limits of detection were between 0.1 and 5.2 µg/L, far below the maximum residue levels for milk set by the EU regulations. While matrix effects—ion suppression or enhancement—are obtained for all the analytes the method has proved to be useful for screening purposes because of its sensitivity, linearity and repeatability. Furthermore, when performing the routine analysis of the raw milk samples, no false positive or negative results were obtained. PMID:20379812

  12. Screening Douglas-fir for rapid early growth in common-garden tests in Spain

    Treesearch

    Gabriel Toval Hernandez; Guillermo Vega Alonso; Gonzalo Puerto Arribas; James L. Jenkinson

    1993-01-01

    Douglas-firs from 91 seed sources in North America were evaluated after 5 and 6 years in 15 common-garden tests in the mountainous regions of northwest and north central Spain. Analyses of tallest trees showed that most of the sources of highest potential for reforestation in Spain are found in regions where the Pacific Ocean air mass dominates climate. Fast growers...

  13. Ultrasensitive Immunochromatographic Strip for Fast Screening of 27 Sulfonamides in Honey and Pork Liver Samples Based on a Monoclonal Antibody.

    PubMed

    Chen, Yanni; Guo, Lingling; Liu, Liqiang; Song, Shanshan; Kuang, Hua; Xu, Chuanlai

    2017-09-20

    Group-specific monoclonal antibodies (Mabs) with selectivity for 27 sulfonamides were developed based on new combinations of immunogen and coating antigen. The Mab was able to recognize 27 sulfonamides with 50% inhibition concentration (IC 50 ) values ranging from 0.15 to 15.38 μg/L. In particular, the IC 50 values for five sulfonamides (sulfamethazine, sulfaquinoxaline, sulfamonomethoxine, sulfadimethoxine, and sulfamethoxazole) were 0.51, 0.15, 0.56, 0.54, and 2.14 μg/L, respectively. On the basis of the Mab, an immunochromatographic lateral flow strip test was established for rapid screening of sulfonamides in honey samples. The visual limit of detection of the strip test for most sulfonamides in spiked honey samples was below 10 μg/kg, satisfying the requirements of authorities. Positive honey and pork liver samples, which had been confirmed by high-performance liquid chromatography/mass spectrometry, were used to validate the reliability of the proposed strip test. The immunochromatographic lateral flow strip test provides a rapid and convenient method for fast screening of sulfonamides in honey samples.

  14. Screening Anti-Cancer Drugs against Tubulin using Catch-and-Release Electrospray Ionization Mass Spectrometry

    NASA Astrophysics Data System (ADS)

    Rezaei Darestani, Reza; Winter, Philip; Kitova, Elena N.; Tuszynski, Jack A.; Klassen, John S.

    2016-05-01

    Tubulin, which is the building block of microtubules, plays an important role in cell division. This critical role makes tubulin an attractive target for the development of chemotherapeutic drugs to treat cancer. Currently, there is no general binding assay for tubulin-drug interactions. The present work describes the application of the catch-and-release electrospray ionization mass spectrometry (CaR-ESI-MS) assay to investigate the binding of colchicinoid drugs to αβ-tubulin dimers extracted from porcine brain. Proof-of-concept experiments using positive (ligands with known affinities) and negative (non-binders) controls were performed to establish the reliability of the assay. The assay was then used to screen a library of seven colchicinoid analogues to test their binding to tubulin and to rank their affinities.

  15. Screening for colorectal cancer with FOBT, virtual colonoscopy and optical colonoscopy: study protocol for a randomized controlled trial in the Florence district (SAVE study)

    PubMed Central

    2013-01-01

    Background Colorectal cancer (CRC) is the most frequent cancer in Europe. Randomized clinical trials demonstrated that screening with fecal occult blood test (FOBT) reduces mortality from CRC. Accordingly, the European Community currently recommends population-based screening with FOBT. Other screening tests, such as computed tomography colonography (CTC) and optical colonoscopy (OC), are highly accurate for examining the entire colon for adenomas and CRC. Acceptability represents a critical determinant of the impact of a screening program. We designed a randomized controlled trial to compare participation rate and diagnostic yield of FOBT, CTC with computer-aided diagnosis, and OC as primary tests for population-based screening. Methods/Design A total of 14,000 subjects aged 55 to 64 years, living in the Florence district and never screened for CRC, will be randomized in three arms: group 1 (5,000 persons) invited to undergo CTC (divided into: subgroup 1A with reduced cathartic preparation and subgroup 1B with standard bowel preparation); group 2 (8,000 persons) invited to undergo a biannual FOBT for three rounds; and group 3 (1,000 persons) invited to undergo OC. Subjects of each group will be invited by mail to undergo the selected test. All subjects with a positive FOBT or CTC test (that is, mass or at least one polyp ≥6 mm) will be invited to undergo a second-level OC. Primary objectives of the study are to compare the participation rate to FOBT, CTC and OC; to compare the detection rate for cancer or advanced adenomas of CTC versus three rounds of biannual FOBT; to evaluate referral rate for OC induced by primary CTC versus three rounds of FOBT; and to estimate costs of the three screening strategies. A secondary objective of the study is to create a biological bank of blood and stool specimens from subjects undergoing CTC and OC. Discussion This study will provide information about participation/acceptability, diagnostic yield and costs of screening with CTC in comparison with the recommended test (FOBT) and OC. Trial registration ClinicalTrials.gov Identifier: NCT01651624. PMID:23497601

  16. A qualitative exploration of Malaysian cancer patients’ perceptions of cancer screening

    PubMed Central

    2013-01-01

    Background Despite the existence of different screening methods, the response to cancer screening is poor among Malaysians. The current study aims to examine cancer patients’ perceptions of cancer screening and early diagnosis. Methods A qualitative methodology was used to collect in-depth information from cancer patients. After obtaining institutional ethical approval, patients with different types and stages of cancer from the three major ethnic groups (Malay, Chinese and Indian) were approached. Twenty semi-structured interviews were conducted. All interviews were audiotaped, transcribed verbatim, and translated into English for thematic content analysis. Results Thematic content analysis yielded four major themes: awareness of cancer screening, perceived benefits of cancer screening, perceived barriers to cancer screening, and cues to action. The majority of respondents had never heard of cancer screening before their diagnosis. Some participants reported hearing about mammogram and Pap smear tests but did not undergo screening due to a lack of belief in personal susceptibility. Those who had negative results from screening prior to diagnosis perceived such tests as untrustworthy. Lack of knowledge and financial constraints were reported as barriers to cancer screening. Finally, numerous suggestions were given to improve screening behaviour among healthy individuals, including the role of mass media in disseminating the message ‘prevention is better than cure’. Conclusions Patients’ narratives revealed some significant issues that were in line with the Health Belief Model which could explain negative health behaviour. The description of the personal experiences of people with cancer could provide many cues to action for those who have never encountered this potentially deadly disease, if incorporated into health promotion activities. PMID:23331785

  17. A qualitative exploration of Malaysian cancer patients' perceptions of cancer screening.

    PubMed

    Farooqui, Maryam; Hassali, Mohamed Azmi; Knight, Aishah; Shafie, Asrul Akmal; Farooqui, Muhammad Aslam; Saleem, Fahad; Haq, Noman-ul; Aljadhey, Hisham

    2013-01-18

    Despite the existence of different screening methods, the response to cancer screening is poor among Malaysians. The current study aims to examine cancer patients' perceptions of cancer screening and early diagnosis. A qualitative methodology was used to collect in-depth information from cancer patients. After obtaining institutional ethical approval, patients with different types and stages of cancer from the three major ethnic groups (Malay, Chinese and Indian) were approached. Twenty semi-structured interviews were conducted. All interviews were audiotaped, transcribed verbatim, and translated into English for thematic content analysis. Thematic content analysis yielded four major themes: awareness of cancer screening, perceived benefits of cancer screening, perceived barriers to cancer screening, and cues to action. The majority of respondents had never heard of cancer screening before their diagnosis. Some participants reported hearing about mammogram and Pap smear tests but did not undergo screening due to a lack of belief in personal susceptibility. Those who had negative results from screening prior to diagnosis perceived such tests as untrustworthy. Lack of knowledge and financial constraints were reported as barriers to cancer screening. Finally, numerous suggestions were given to improve screening behaviour among healthy individuals, including the role of mass media in disseminating the message 'prevention is better than cure'. Patients' narratives revealed some significant issues that were in line with the Health Belief Model which could explain negative health behaviour. The description of the personal experiences of people with cancer could provide many cues to action for those who have never encountered this potentially deadly disease, if incorporated into health promotion activities.

  18. Fatty acid ethyl esters (FAEEs) as markers for alcohol in meconium: method validation and implementation of a screening program for prenatal drug exposure.

    PubMed

    Hastedt, Martin; Krumbiegel, Franziska; Gapert, René; Tsokos, Michael; Hartwig, Sven

    2013-09-01

    Alcohol consumption during pregnancy is a widespread problem and can cause severe fetal damage. As the diagnosis of fetal alcohol syndrome is difficult, the implementation of a reliable marker for alcohol consumption during pregnancy into meconium drug screening programs would be invaluable. A previously published gas chromatography mass spectrometry method for the detection of fatty acid ethyl esters (FAEEs) as alcohol markers in meconium was optimized and newly validated for a sample size of 50 mg. This method was applied to 122 cases from a drug-using population. The meconium samples were also tested for common drugs of abuse. In 73 % of the cases, one or more drugs were found. Twenty percent of the samples tested positive for FAEEs at levels indicating significant alcohol exposure. Consequently, alcohol was found to be the third most frequently abused substance within the study group. This re-validated method provides an increase in testing sensitivity, is reliable and easily applicable as part of a drug screening program. It can be used as a non-invasive tool to detect high alcohol consumption in the last trimester of pregnancy. The introduction of FAEEs testing in meconium screening was found to be of particular use in a drug-using population.

  19. Second-tier test for quantification of underivatized amino acids in dry blood spot for metabolic diseases in newborn screening.

    PubMed

    Wang, Chunyan; Zhu, Hongbin; Zhang, Wenyan; Song, Fengrui; Liu, Zhiqiang; Liu, Shuying

    2013-02-01

    The quantitative analysis of amino acids (AAs) in single dry blood spot (DBS) samples is an important issue for metabolic diseases as a second-tier test in newborn screening. An analytical method for quantifying underivatized AAs in DBS was developed by using liquid chromatography coupled with tandem mass spectrometry (LC-MS/MS). The sample preparation in this method is simple and ion-pairing agent is not used in the mobile phase that could avoid ion suppression, which happens in mass spectrometry and avoids damage to the column. Through chromatographic separation, some isomeric compounds could be identified and quantified, which cannot be solved through only appropriate multiple reactions monitoring transitions by MS/MS. The concentrations of the different AAs were determined using non-deuterated internal standard. All calibration curves showed excellent linearity within test ranges. For most of the amino acids the accuracy of extraction recovery was between 85.3 and 115 %, and the precision of relative standard deviation was <7.0 %. The 35 AAs could be identified in DBS specimens by the developed LC-MS/MS method in 17-19 min, and eventually 24 AAs in DBS were quantified. The results of the present study prove that this method as a second-tier test in newborn screening for metabolic diseases could be performed by the quantification of free AAs in DBS using the LC-MS/MS method. The assay has advantages of high sensitive, specific, and inexpensive merits because non-deuterated internal standard and acetic acid instead of ion-pairing agent in mobile phase are used in this protocol.

  20. Racial/Ethnic Differences Affecting Adherence to Cancer Screening Guidelines Among Women.

    PubMed

    Hirth, Jacqueline M; Laz, Tabassum Haque; Rahman, Mahbubur; Berenson, Abbey B

    2016-04-01

    Race/ethnicity has been shown to modify the effects between obesity and cancer screening among women. The purpose of this article is to update the literature with recent data to examine how the association between different characteristics, including body mass index (BMI), and cancer screening compliance varies by race/ethnicity in a national sample of women. Three cycles of the Health Information National Trends Survey (HINTS) were combined for this cross-sectional study. Weighted descriptive statistics were evaluated using chi-square tests. Multivariable logistic regression evaluated associations between women with underweight or normal (<25), overweight (25-29.9), and obese (>30) BMIs and cancer screening concordant with guidelines (Papanicolaou [Pap] testing ≤3 years, ages 21+ years; mammography ≤2 years, ages 40+ years) in analyses stratified by race/ethnicity. We also assessed variance between racial/ethnic groups in how age, income, and insurance status were associated with cancer screening compliance. This study included 4992 women who were evaluated for Pap testing and 3773 for mammography. In analyses stratified by race/ethnicity, whites with a higher household income were more likely to report having a Pap test (adjusted prevalence ratio [aPR] 2.16, 95% confidence interval [95% CI] 1.38-3.40) and a mammogram (aPR 1.63, 95% CI 1.04-2.55) compared to lower income white women. Black women with BMIs between 25 and 30 were less likely to receive a Pap test (aPR 0.38, 95% CI 0.19-0.76) than black women with BMIs <25, while no association was observed among the other groups. Insurance was associated with increased likelihood of Pap testing among white and black women. Insurance coverage was positively associated with mammography only among white and Hispanic women. We found variations in adherence to cancer screening guidelines by age, insurance coverage, and income between racial/ethnic groups. Little evidence was observed for variations in screening by BMI.

  1. Newborn screening: a review of history, recent advancements, and future perspectives in the era of next generation sequencing.

    PubMed

    Almannai, Mohammed; Marom, Ronit; Sutton, V Reid

    2016-12-01

    The purpose of this review is to summarize the development and recent advancements of newborn screening. Early initiation of medical care has modified the outcome for many disorders that were previously associated with high morbidity (such as cystic fibrosis, primary immune deficiencies, and inborn errors of metabolism) or with significant neurodevelopmental disabilities (such as phenylketonuria and congenital hypothyroidism). The new era of mass spectrometry and next generation sequencing enables the expansion of the newborn screen panel, and will help to address technical issues such as turnaround time, and decreasing false-positive and false-negative rates for the testing. The newborn screening program is a successful public health initiative that facilitates early diagnosis of treatable disorders to reduce long-term morbidity and mortality.

  2. Newborn screening by tandem mass spectrometry: ethical and social issues.

    PubMed

    Avard, Denise; Vallance, Hilary; Greenberg, Cheryl; Potter, Beth

    2007-01-01

    Emerging technologies like Tandem Mass Spectrometry (TMS) enable multiple tests on a single blood sample and allow the expansion of Newborn Screening (NBS) to include various metabolic diseases. Introducing TMS for NBS raises important social and ethical questions: what are the criteria for adding disorders to screening panels? What evidence justifies expansion of screening? How can equity in NBS access and standards be ensured? How can policy standards be set, given the multiplicity of stakeholders? To address emerging issues, policy-makers, patient advocates, clinicians and researchers had a workshop during the 2005 Garrod Symposium. The participants received a summary of the discussion and understood the workshop's goal was to provide a basis for further discussion. This article contributes to this ongoing discussion. Several proposed recommendations assert the centrality of including social and ethical issues in the assessment of whether or not to introduce TMS. The article outlines five key recommendations for advancing the NBS agenda: national public health leadership; transparency; increased national consistency in NBS strategy, including minimum standards; collaboration between the federal and provincial/territorial governments and diverse stakeholders; and supporting research and/or programs based on effectiveness, which integrate ethical and social issues into assessment.

  3. Development of a Magnetic Microbead Affinity Selection Screen (MagMASS) Using Mass Spectrometry for Ligands to the Retinoid X Receptor-α

    NASA Astrophysics Data System (ADS)

    Rush, Michael D.; Walker, Elisabeth M.; Prehna, Gerd; Burton, Tristesse; van Breemen, Richard B.

    2017-03-01

    To overcome limiting factors in mass spectrometry-based screening methods such as automation while still facilitating the screening of complex mixtures such as botanical extracts, magnetic microbead affinity selection screening (MagMASS) was developed. The screening process involves immobilization of a target protein on a magnetic microbead using a variety of possible chemistries, incubation with mixtures of molecules containing possible ligands, a washing step that removes non-bound compounds while a magnetic field retains the beads in the microtiter well, and an organic solvent release step followed by LC-MS analysis. Using retinoid X receptor-α (RXRα) as an example, which is a nuclear receptor and target for anti-inflammation therapy as well as cancer treatment and prevention, a MagMASS assay was developed and compared with an existing screening assay, pulsed ultrafiltration (PUF)-MS. Optimization of MagMASS involved evaluation of multiple protein constructs and several magnetic bead immobilization chemistries. The full-length RXRα construct immobilized with amylose beads provided optimum results. Additional enhancements of MagMASS were the application of 96-well plates to enable automation, use of UHPLC instead of HPLC for faster MS analyses, and application of metabolomics software for faster, automated data analysis. Performance of MagMASS was demonstrated using mixtures of synthetic compounds and known ligands spiked into botanical extracts.

  4. Districts Weigh Obesity Screening

    ERIC Educational Resources Information Center

    Butler, Kevin

    2008-01-01

    Parents of children in most elementary grades in Minnesota's Independent School District 191 receive an annual notice with potentially life-altering data for their children--and they are not state test scores, attendance rates, or grades. The notice contains the child's body mass index (BMI) score, which estimates whether the student has excess…

  5. SCREENING PROCESSED MILK FOR VOLATILE ORGANIC COMPOUNDS USING VACUUM DISTILLATION/GAS CHROMATOGRAPHY/MASS SPECTROMETRY

    EPA Science Inventory

    An adaptation of Office of Solid Waste and Emergency Response' Test Methods for Evaluating Solid Waste Physical/Chemical Methods (SW-846) method 8261 to analyze milk for an expanded list of volatile organic compounds is presented. The milk matriz exhibits a strong affinity for o...

  6. [Mass neonatal screening using biological testing].

    PubMed

    Ardaillou, R; Le Gall, J-Y

    2007-04-01

    Implementation of a generalized screening program for neonatal diseases obeys precise guidelines. The disease must be severe, recognizable at an early stage, accessible to an effective treatment, detected with a non expansive and widely applicable test and it must represent an important health problem. In case of positive results, treatment or prevention shall be offered immediately and any screening program has to be regularly evaluated. There is in France since 1978 a national screening program that depends on a private association ("Association française pour le dépistage et la prévention des handicaps de l'enfant") and is supervised by the "Caisse nationale d'assurance maladie" and the "Direction Générale de la Sante". Presently, five diseases are included in the screening program: phenylketonuria, hypothyroidism, congenital adrenal hyperplasia, cystic fibrosis and sickle cell disease, the latter only in at risk newborns. Toxoplasmosis represents a particular problem because screening takes place only in children of mothers that have not been controlled during their pregnancy or in case of seroconversion. Neonatal screening of phenylketonuria and hypothyrodism is unanimously recommended. That of congenital adrenal hyperplasia is approved in most countries. The cases of sickle cell disease and cystic fibrosis are more complex because: 1) all the children that carry the mutations are not affected with a severe disease; 2) there is no curative treatment; 3) parents given information are made anxious, sometimes wrongly if the disease is mild or asymptomatic. The supporters of the screening insist on the interest of an early diagnosis which makes longer the life time of these children, the possibility for the parents to utilize prenatal screening in case of a future pregnancy, and the information given to the heterozygous carriers following a familial screening. The question is raised of the extension of neonatal screening to other diseases. This is now possible due to technical progresses such as the tandem mass spectrometry that can detect about 50 diseases in an only testing. In addition of its cost and of the difficulty to ensure an efficient organization, increasing the number of the screened diseases will raise ethical problems including how the parents will be informed of an incurable disease or a late-onset disease or an entirely asymptomatic disease. It is unanimously admitted that only mendelian diseases should be detected excluding genetic polymorphisms. Analysis of the present situation suggests the following developments: 1) to actualize the guidelines for deciding of a new neonatal screening; 2) to experiment on a local scale any new screening before its extension to the whole country; 3) to create an evaluation committee including paediatricians and epidemiologists and to evaluate on the long term the future of the children; 4) to precisely define the conditions in which the heterozygous carriers will be informed following a familial investigation; 5) to store in a resource biological centre the blood samples in order to utilize this bank for epidemiology studies.

  7. Sample-to-answer palm-sized nucleic acid testing device towards low-cost malaria mass screening.

    PubMed

    Choi, Gihoon; Prince, Theodore; Miao, Jun; Cui, Liwang; Guan, Weihua

    2018-05-19

    The effectiveness of malaria screening and treatment highly depends on the low-cost access to the highly sensitive and specific malaria test. We report a real-time fluorescence nucleic acid testing device for malaria field detection with automated and scalable sample preparation capability. The device consists a compact analyzer and a disposable microfluidic reagent compact disc. The parasite DNA sample preparation and subsequent real-time LAMP detection were seamlessly integrated on a single microfluidic compact disc, driven by energy efficient non-centrifuge based magnetic field interactions. Each disc contains four parallel testing units which could be configured either as four identical tests or as four species-specific tests. When configured as species-specific tests, it could identify two of the most life-threatening malaria species (P. falciparum and P. vivax). The NAT device is capable of processing four samples simultaneously within 50 min turnaround time. It achieves a detection limit of ~0.5 parasites/µl for whole blood, sufficient for detecting asymptomatic parasite carriers. The combination of the sensitivity, specificity, cost, and scalable sample preparation suggests the real-time fluorescence LAMP device could be particularly useful for malaria screening in the field settings. Copyright © 2018 Elsevier B.V. All rights reserved.

  8. Endometrial cancer, cervical cancer, and the adnexal mass.

    PubMed

    Fontaine, P

    1998-06-01

    Cancers of the endometrium, cervix, and ovaries account for nearly 25,000 annual deaths among women in the United States. In recent years, better understanding of the causes and risk factors associated with gynecologic malignancies has contributed to more effective screening and early diagnosis. Abnormal uterine bleeding, a palpable adnexal mass, or vague abdominal complaints in women older than 40 can be signs of cancer. Regular pelvic examination, combined with appropriate use of the Papanicolaou's smear, endometrial biopsy, transvaginal sonography, and other tests, is recommended.

  9. The cystic fibrosis gene: Medical and social implications for heterozygote detection

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Wilfond, B.S.; Fost, N.

    1990-05-23

    The primary goal of mass screening programs for cystic fibrosis carriers should be to allow people to make more informed reproductive decisions. However, previous experience with genetic screening programs, including those for phenylketonuria and sickle cell disease, have revealed complex problems including error, confusion, and stigmatization. These problems could be greater with cystic fibrosis, since more than 8 million Americans may be carriers and entrepreneurial interests can be expected to promote screening in what could become a billion-dollar industry. The present frequency of the detectable mutation ({Delta}F{sub 508}), 75%, will complicate the counseling process. The sensitivity of the test tomore » detect at-risk couples would be 56%. The cost of screening could be as much as $2.2 million for each cystic fibrosis birth avoided. Regardless of improvements in the detection rate, implementation of population screening should be delayed until pilot studies that demonstrate its safety and effectiveness are completed. While studies are in progress, preconception testing should be offered to adult relatives of cystic fibrosis patients as part of a comprehensive program following institutional review board approval for compassionate use.« less

  10. High-resolution chromatography/time-of-flight MSE with in silico data mining is an information-rich approach to reactive metabolite screening.

    PubMed

    Barbara, Joanna E; Castro-Perez, Jose M

    2011-10-30

    Electrophilic reactive metabolite screening by liquid chromatography/mass spectrometry (LC/MS) is commonly performed during drug discovery and early-stage drug development. Accurate mass spectrometry has excellent utility in this application, but sophisticated data processing strategies are essential to extract useful information. Herein, a unified approach to glutathione (GSH) trapped reactive metabolite screening with high-resolution LC/TOF MS(E) analysis and drug-conjugate-specific in silico data processing was applied to rapid analysis of test compounds without the need for stable- or radio-isotope-labeled trapping agents. Accurate mass defect filtering (MDF) with a C-heteroatom dealkylation algorithm dynamic with mass range was compared to linear MDF and shown to minimize false positive results. MS(E) data-filtering, time-alignment and data mining post-acquisition enabled detection of 53 GSH conjugates overall formed from 5 drugs. Automated comparison of sample and control data in conjunction with the mass defect filter enabled detection of several conjugates that were not evident with mass defect filtering alone. High- and low-energy MS(E) data were time-aligned to generate in silico product ion spectra which were successfully applied to structural elucidation of detected GSH conjugates. Pseudo neutral loss and precursor ion chromatograms derived post-acquisition demonstrated 50.9% potential coverage, at best, of the detected conjugates by any individual precursor or neutral loss scan type. In contrast with commonly applied neutral loss and precursor-based techniques, the unified method has the advantage of applicability across different classes of GSH conjugates. The unified method was also successfully applied to cyanide trapping analysis and has potential for application to alternate trapping agents. Copyright © 2011 John Wiley & Sons, Ltd.

  11. A parametrisation of modified gravity on nonlinear cosmological scales

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Lombriser, Lucas, E-mail: llo@roe.ac.uk

    2016-11-01

    Viable modifications of gravity on cosmological scales predominantly rely on screening mechanisms to recover Einstein's Theory of General Relativity in the Solar System, where it has been well tested. A parametrisation of the effects of such modifications in the spherical collapse model is presented here for the use of modelling the modified nonlinear cosmological structure. The formalism allows an embedding of the different screening mechanisms operating in scalar-tensor theories through large values of the gravitational potential or its first or second derivatives as well as of linear suppression effects or more general transitions between modified and Einstein gravity limits. Eachmore » screening or suppression mechanism is parametrised by a time, mass, and environment dependent screening scale, an effective modified gravitational coupling in the fully unscreened limit that can be matched to linear theory, the exponent of a power-law radial profile of the screened coupling, determined by derivatives, symmetries, and potentials in the scalar field equation, and an interpolation rate between the screened and unscreened limits. Along with generalised perturbative methods, the parametrisation may be used to formulate a nonlinear extension to the linear parametrised post-Friedmannian framework to enable generalised tests of gravity with the wealth of observations from the nonlinear cosmological regime.« less

  12. Early Detection and Mass Screening For Cancer

    PubMed Central

    Miller, A. B.

    1972-01-01

    The author reviews the evidence for the efficacy of early detection and mass screening programs in reducing morbidity and mortality from cancer. In cancer of the cervix, although screening reduces morbidity, we still do not have evidence for reduction in mortality. In cancer of the breast, one study suggests a reduction in mortality in the 50-59 year age group following screening by clinical examination and mammography. In other sites, especially lung, there is no evidence at present to support the adoption of mass screening programs. It is important that such programs should be carefully evaluated in the population, preferably in controlled studies. PMID:20468806

  13. Tablets at the bedside - iPad-based visual field test used in the diagnosis of Intrasellar Haemangiopericytoma: a case report.

    PubMed

    Nesaratnam, Nisha; Thomas, Peter B M; Kirollos, Ramez; Vingrys, Algis J; Kong, George Y X; Martin, Keith R

    2017-04-24

    In the assessment of a pituitary mass, objective visual field testing represents a valuable means of evaluating mass effect, and thus in deciding whether surgical management is warranted. In this vignette, we describe a 73 year-old lady who presented with a three-week history of frontal headache, and 'blurriness' in the left side of her vision, due to a WHO grade III anaplastic haemangiopericytoma compressing the optic chiasm. We report how timely investigations, including an iPad-based visual field test (Melbourne Rapid Field, (MRF)) conducted at the bedside aided swift and appropriate management of the patient. We envisage such a test having a role in assessing bed-bound patients in hospital where access to formal visual field testing is difficult, or indeed in rapid testing of visual fields at the bedside to screen for post-operative complications, such as haematoma.

  14. Lightweight Ablative and Ceramic Thermal Protection System Materials for NASA Exploration Systems Vehicles

    NASA Technical Reports Server (NTRS)

    Valentine, Peter G.; Lawrence, Timothy W.; Gubert, Michael K.; Milos, Frank S.; Kiser, James D.; Ohlhorst, Craig W.; Koenig, John R.

    2006-01-01

    As a collaborative effort among NASA Centers, the "Lightweight Nonmetallic Thermal Protection Materials Technology" Project was set up to assist mission/vehicle design trade studies, to support risk reduction in thermal protection system (TPS) material selections, to facilitate vehicle mass optimization, and to aid development of human-rated TPS qualification and certification plans. Missions performing aerocapture, aerobraking, or direct aeroentry rely on advanced heatshields that allow reductions in spacecraft mass by minimizing propellant requirements. Information will be presented on candidate materials for such reentry approaches and on screening tests conducted (material property and space environmental effects tests) to evaluate viable candidates. Seventeen materials, in three classes (ablatives, tiles, and ceramic matrix composites), were studied. In additional to physical, mechanical, and thermal property tests, high heat flux laser tests and simulated-reentry oxidation tests were performed. Space environmental effects testing, which included exposures to electrons, atomic oxygen, and hypervelocity impacts, was also conducted.

  15. Regional Differences as Barriers to Body Mass Index Screening Described by Ohio School Nurses

    ERIC Educational Resources Information Center

    Stalter, Ann M.; Chaudry, Rosemary V.; Polivka, Barbara J.

    2011-01-01

    Background: Body mass index (BMI) screening is advocated by the National Association of School Nurses (NASN). Research identifying barriers to BMI screening in public elementary school settings has been sparse. The purpose of the study was to identify barriers and facilitating factors of BMI screening practices among Ohio school nurses working in…

  16. High-performance thin-layer chromatography screening of multi class antibiotics in animal food by bioluminescent bioautography and electrospray ionization mass spectrometry.

    PubMed

    Chen, Yisheng; Schwack, Wolfgang

    2014-08-22

    The world-wide usage and partly abuse of veterinary antibiotics resulted in a pressing need to control residues in animal-derived foods. Large-scale screening for residues of antibiotics is typically performed by microbial agar diffusion tests. This work employing high-performance thin-layer chromatography (HPTLC) combined with bioautography and electrospray ionization mass spectrometry introduces a rapid and efficient method for a multi-class screening of antibiotic residues. The viability of the bioluminescent bacterium Aliivibrio fischeri to the studied antibiotics (16 species of 5 groups) was optimized on amino plates, enabling detection sensitivity down to the strictest maximum residue limits. The HPTLC method was developed not to separate the individual antibiotics, but for cleanup of sample extracts. The studied antibiotics either remained at the start zones (tetracyclines, aminoglycosides, fluoroquinolones, and macrolides) or migrated into the front (amphenicols), while interfering co-extracted matrix compounds were dispersed at hRf 20-80. Only after a few hours, the multi-sample plate image clearly revealed the presence or absence of antibiotic residues. Moreover, molecular information as to the suspected findings was rapidly achieved by HPTLC-mass spectrometry. Showing remarkable sensitivity and matrix-tolerance, the established method was successfully applied to milk and kidney samples. Copyright © 2014 Elsevier B.V. All rights reserved.

  17. Random plasma glucose in serendipitous screening for glucose intolerance: screening for impaired glucose tolerance study 2.

    PubMed

    Ziemer, David C; Kolm, Paul; Foster, Jovonne K; Weintraub, William S; Vaccarino, Viola; Rhee, Mary K; Varughese, Rincy M; Tsui, Circe W; Koch, David D; Twombly, Jennifer G; Narayan, K M Venkat; Phillips, Lawrence S

    2008-05-01

    With positive results from diabetes prevention studies, there is interest in convenient ways to incorporate screening for glucose intolerance into routine care and to limit the need for fasting diagnostic tests. The aim of this study is to determine whether random plasma glucose (RPG) could be used to screen for glucose intolerance. This is a cross-sectional study. The participants of this study include a voluntary sample of 990 adults not known to have diabetes. RPG was measured, and each subject had a 75-g oral glucose tolerance test several weeks later. Glucose intolerance targets included diabetes, impaired glucose tolerance (IGT), and impaired fasting glucose(110) (IFG(110); fasting glucose, 110-125 mg/dl, and 2 h glucose < 140 mg/dl). Screening performance was measured by area under receiver operating characteristic curves (AROC). Mean age was 48 years, and body mass index (BMI) was 30.4 kg/m(2); 66% were women, and 52% were black; 5.1% had previously unrecognized diabetes, and 24.0% had any "high-risk" glucose intolerance (diabetes or IGT or IFG(110)). The AROC was 0.80 (95% CI 0.74-0.86) for RPG to identify diabetes and 0.72 (0.68-0.75) to identify any glucose intolerance, both highly significant (p < 0.001). Screening performance was generally consistent at different times of the day, regardless of meal status, and across a range of risk factors such as age, BMI, high density lipoprotein cholesterol, triglycerides, and blood pressure. RPG values should be considered by health care providers to be an opportunistic initial screening test and used to prompt further evaluation of patients at risk of glucose intolerance. Such "serendipitous screening" could help to identify unrecognized diabetes and prediabetes.

  18. Cost-effectiveness simulation and analysis of colorectal cancer screening in Hong Kong Chinese population: comparison amongst colonoscopy, guaiac and immunologic fecal occult blood testing.

    PubMed

    Wong, Carlos K H; Lam, Cindy L K; Wan, Y F; Fong, Daniel Y T

    2015-10-15

    The aim of this study was to evaluate the cost-effectiveness of CRC screening strategies from the healthcare service provider perspective based on Chinese population. A Markov model was constructed to compare the cost-effectiveness of recommended screening strategies including annual/biennial guaiac fecal occult blood testing (G-FOBT), annual/biennial immunologic FOBT (I-FOBT), and colonoscopy every 10 years in Chinese aged 50 year over a 25-year period. External validity of model was tested against data retrieved from published randomized controlled trials of G-FOBT. Recourse use data collected from Chinese subjects among staging of colorectal neoplasm were combined with published unit cost data ($USD in 2009 price values) to estimate a stage-specific cost per patient. Quality-adjusted life-years (QALYs) were quantified based on the stage duration and SF-6D preference-based value of each stage. The cost-effectiveness outcome was the incremental cost-effectiveness ratio (ICER) represented by costs per life-years (LY) and costs per QALYs gained. In base-case scenario, the non-dominated strategies were annual and biennial I-FOBT. Compared with no screening, the ICER presented $20,542/LYs and $3155/QALYs gained for annual I-FOBT, and $19,838/LYs gained and $2976/QALYs gained for biennial I-FOBT. The optimal screening strategy was annual I-FOBT that attained the highest ICER at the threshold of $50,000 per LYs or QALYs gained. The Markov model informed the health policymakers that I-FOBT every year may be the most effective and cost-effective CRC screening strategy among recommended screening strategies, depending on the willingness-to-pay of mass screening for Chinese population. ClinicalTrials.gov Identifier NCT02038283.

  19. [Cost effectiveness of mass orthoptic screening in kindergarten for early detection of developmental vision disorders].

    PubMed

    König, H H; Barry, J C; Leidl, R; Zrenner, E

    2000-04-01

    Orthoptic screening in the kindergarten is one option to improve early detection of amblyopia in children aged 3 years. The purpose of this study was to analyse the cost-effectiveness of such a screening programme in Germany. Based on data from the literature and own experience gained from orthoptic screening in kindergarten a decision-analytic model was developed. According to the model, all children in kindergarten, aged 3 years, who had not been treated for amblyopia before, were subjected to an orthoptic examination. Non-cooperative children were reexamined in kindergarten after one year. Children with positive test results were examined by an ophthalmologist for diagnosis. Effects were measured by the number of newly diagnosed cases of amblyopia, non-obvious strabismus and amblyogenic refractive errors. Direct costs were estimated from a third-party payer perspective. The influence of uncertain model parameters was tested by sensitivity analysis. In the base analysis the cost per orthoptic screening test was DM 15.39. Examination by an ophthalmologist cost DM 71.20. The total cost of the screening programme in all German kindergartens was DM 6.1 million. With a 1.5% age-specific prevalence of undiagnosed cases, a sensitivity of 95% and a specificity of 98%, a total of 4,261 new cases would be detected. The cost-effectiveness ratio was DM 1,421 per case detected. Sensitivity analysis showed considerable influence of prevalence and specificity on the cost-effectiveness ratio. It was more cost-effective to re-screen non-cooperative children in kindergarten than to have them examined by an ophthalmologist straight-away. The decision-analytic model showed stable results which may serve as a basis for discussion on the implementation of orthoptic screening and for planning a field study.

  20. Cosmic web and environmental dependence of screening: Vainshtein vs. chameleon

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Falck, Bridget; Koyama, Kazuya; Zhao, Gong-Bo, E-mail: bridget.falck@port.ac.uk, E-mail: kazuya.koyama@port.ac.uk, E-mail: gong-bo.zhao@port.ac.uk

    Theories which modify general relativity to explain the accelerated expansion of the Universe often use screening mechanisms to satisfy constraints on Solar System scales. We investigate the effects of the cosmic web and the local environmental density of dark matter halos on the screening properties of the Vainshtein and chameleon screening mechanisms. We compare the cosmic web morphology of dark matter particles, mass functions of dark matter halos, mass and radial dependence of screening, velocity dispersions and peculiar velocities, and environmental dependence of screening mechanisms in f(R) and nDGP models. Using the ORIGAMI cosmic web identification routine we find thatmore » the Vainshtein mechanism depends on the cosmic web morphology of dark matter particles, since these are defined according to the dimensionality of their collapse, while the chameleon mechanism shows no morphology dependence. The chameleon screening of halos and their velocity dispersions depend on halo mass, and small halos and subhalos can be environmentally screened in the chameleon mechanism. On the other hand, the screening of halos in the Vainshtein mechanism does not depend on mass nor environment, and their velocity dispersions are suppressed. The peculiar velocities of halos in the Vainshtein mechanism are enhanced because screened objects can still feel the fifth force generated by external fields, while peculiar velocities of chameleon halos are suppressed when the halo centers are screened.« less

  1. Screening College Students for Hypercholesterolemia.

    ERIC Educational Resources Information Center

    Faigel, Harris C.

    1992-01-01

    Describes one college's mandatory mass cholesterol screening for new students. Each year, over 30 beginning students with unknown hypercholesterolemia were detected. The program suggests that mass screening efficiently and economically identifies students who would benefit from cholesterol reduction, a modifiable risk in coronary artery disease.…

  2. Applying a new unequally weighted feature fusion method to improve CAD performance of classifying breast lesions

    NASA Astrophysics Data System (ADS)

    Zargari Khuzani, Abolfazl; Danala, Gopichandh; Heidari, Morteza; Du, Yue; Mashhadi, Najmeh; Qiu, Yuchen; Zheng, Bin

    2018-02-01

    Higher recall rates are a major challenge in mammography screening. Thus, developing computer-aided diagnosis (CAD) scheme to classify between malignant and benign breast lesions can play an important role to improve efficacy of mammography screening. Objective of this study is to develop and test a unique image feature fusion framework to improve performance in classifying suspicious mass-like breast lesions depicting on mammograms. The image dataset consists of 302 suspicious masses detected on both craniocaudal and mediolateral-oblique view images. Amongst them, 151 were malignant and 151 were benign. The study consists of following 3 image processing and feature analysis steps. First, an adaptive region growing segmentation algorithm was used to automatically segment mass regions. Second, a set of 70 image features related to spatial and frequency characteristics of mass regions were initially computed. Third, a generalized linear regression model (GLM) based machine learning classifier combined with a bat optimization algorithm was used to optimally fuse the selected image features based on predefined assessment performance index. An area under ROC curve (AUC) with was used as a performance assessment index. Applying CAD scheme to the testing dataset, AUC was 0.75+/-0.04, which was significantly higher than using a single best feature (AUC=0.69+/-0.05) or the classifier with equally weighted features (AUC=0.73+/-0.05). This study demonstrated that comparing to the conventional equal-weighted approach, using an unequal-weighted feature fusion approach had potential to significantly improve accuracy in classifying between malignant and benign breast masses.

  3. Newborn screening for sickling and other haemoglobin disorders using tandem mass spectrometry: A pilot study of methodology in laboratories in England.

    PubMed

    Daniel, Yvonne A; Henthorn, Joan

    2016-12-01

    To determine (i) if electrospray mass spectrometry-mass spectrometry with the SpOtOn Diagnostics Ltd reagent kit for sickle cell screening could be integrated into the English newborn screening programme, under routine screening conditions, and provide mass spectrometry-mass spectrometry results which match existing methods, and (ii) if common action values could be set for all manufacturers in the study, for all assessed haemoglobins, to indicate which samples require further investigation. Anonymised residual blood spots were analysed using the SpOtOn reagent kit as per manufacturer's instructions, in parallel with existing techniques at four laboratories. Mass spectrometry-mass spectrometry instrumentation at Laboratories A and B was AB Sciex (Warrington, UK) AP4000, and at Laboratories C and D, Waters Micromass (Manchester, UK), Xevo TQMS and Premier, respectively. There were 23,898 results accepted from the four laboratories. Excellent specificity at 100% sensitivity was observed for haemoglobin S, haemoglobin C, haemoglobin E and haemoglobin O Arab . A common action value was not possible for Hb C, but action values were set by manufacturer. The two haemoglobin D Punjab cases at Laboratory D were not detected using the common action value. Conversely, false-positive results with haemoglobin D Punjab were a problem at the remaining three laboratories. This multicentre study demonstrates that it is possible to implement mass spectrometry-mass spectrometry into an established screening programme while maintaining consistency with existing methods for haemoglobinopathy screening. However, one of the instruments investigated cannot be recommended for use with this application. © The Author(s) 2016.

  4. Clinical Variability in Cardiovascular Disease Risk Factor Screening and Management in Adolescent and Young Adult Women with Polycystic Ovary Syndrome.

    PubMed

    Baer, Tamara E; Milliren, Carly E; Walls, Courtney; DiVasta, Amy D

    2015-10-01

    To review the clinical presentation, evaluation, and management of normal-weight (NW), overweight (OW), and obese (OB) adolescent and young adult women with polycystic ovary syndrome (PCOS) during a 2-year follow-up. Retrospective chart review. One hundred seventy-three adolescent and young adult women, aged 12-22 years, diagnosed with PCOS. Demographic, health data, and laboratory measures were abstracted from 3 clinic visits: baseline and 1- and 2-year follow-up. Subjects were classified as NW, OW, or OB. Longitudinal data were analyzed using repeated-measures analysis of variance. Body mass index, self-reported concerns, and lifestyle changes. Most patients (73%) were OW or OB. Family history of type 2 diabetes was greater in OW (38%) and OB (53%) patients compared with NW (22%) patients (P = .002). Acanthosis nigricans was identified in OW (62%) and OB (21%) patients but not in NW patients (0%; P < .001). OW and OB patients had higher fasting insulin (P < .001) and lower high-density lipoprotein cholesterol (P = .005) levels than NW patients, although screening rates were low. Body mass index Z-scores decreased in both OW and OB patients over time (0.07 unit/yr, P < .001). Most patients with PCOS were OW or OB. Substantial clinical variability existed in cardiovascular disease (CVD) screening; among those screened, OW and OB patients had greater CVD risk factors. Despite self-reported concerns about weight and diabetes risk among OW and OB patients, no clinically significant change in body mass index percentile occurred. Evidence-based interventions and recommendations for screening tests are needed to address CVD risk in adolescents and young adults with PCOS. Copyright © 2015 North American Society for Pediatric and Adolescent Gynecology. Published by Elsevier Inc. All rights reserved.

  5. Multiresidue pesticide analysis in ginseng and spinach by nontargeted and targeted screening procedures.

    PubMed

    Hayward, Douglas G; Wong, Jon W; Zhang, Kai; Chang, James; Shi, Feng; Banerjee, Kaushik; Yang, Paul

    2011-01-01

    Five different mass spectrometers interfaced to GC or LC were evaluated for their application to targeted and nontargeted screening of pesticides in two foods, spinach and ginseng. The five MS systems were capillary GC/MS/MS, GC-high resolution time-of-flight (GC/HR-TOF)-MS, TOF-MS interfaced with a comprehensive multidimensional GC (GCxGC/TOF-MS), an MS/MS ion trap hybrid mass (qTrap) system interfaced with an ultra-performance liquid chromatograph (UPLC-qTrap), and UPLC interfaced to an orbital trap high resolution mass spectrometer (UPLC/Orbitrap HR-MS). Each MS system was tested with spinach and ginseng extracts prepared through a modified quick, easy, cheap, effective, rugged, and safe (QuEChERS) procedure. Each matrix was fortified at 10 and 50 ng/g for spinach or 25 and 100 ng/g for ginseng with subsets of 486 pesticides, isomers, and metabolites representing most pesticide classes. HR-TOF-MS was effective in a targeted search for characteristic accurate mass ions and identified 97% of 170 pesticides in ginseng at 25 ng/g. A targeted screen of either ginseng or spinach found 94-95% of pesticides fortified for analysis at 10 ng/g with GC/MS/MS or LC/MS/MS using multiple reaction monitoring (MRM) procedures. Orbitrap-MS successfully found 89% of 177 fortified pesticides in spinach at 25 ng/g using a targeted search of accurate mass pseudomolecular ions in the positive electrospray ionization mode. A comprehensive GCxGC/TOF-MS system provided separation and identification of 342 pesticides and metabolites in a single 32 min acquisition with standards. Only 67 or 81% of the pesticides were identified in ginseng and spinach matrixes at 25 ng/g or 10 ng/g, respectively. MS/MS or qTrap-MS operated in the MRM mode produced the lowest false-negative rates, at 10 ng/g. Improvements to instrumentation, methods, and software are needed for efficient use of nontargeted screens in parallel with triple quadrupole MS.

  6. Variation with Mach Number of Static and Total Pressures Through Various Screens

    NASA Technical Reports Server (NTRS)

    Adler, Alfred A

    1946-01-01

    Tests were conducted in the Langley 24-inch highspeed tunnel to ascertain the static-pressure and total-pressure losses through screens ranging in mesh from 3 to 12 wires per inch and in wire diameter from 0.023 to 0.041 inch. Data were obtained from a Mach number of approximately 0.20 up to the maximum (choking) Mach number obtainable for each screen. The results of this investigation indicate that the pressure losses increase with increasing Mach number until the choking Mach number, which can be computed, is reached. Since choking imposes a restriction on the mass rate of flow and maximum losses are incurred at this condition, great care must be taken in selecting the screen mesh and wire dimmeter for an installation so that the choking Mach number is

  7. A chamber investigation of the IR and visible wavelength obscuration properties of pyrotechnically generated smokes

    NASA Astrophysics Data System (ADS)

    Hanley, J. T.; Mack, E. J.

    1985-05-01

    The overall objective of the program is the development of an effective screening agent to both visible and IR wavelengths utilizing pyrotechnically-generated hygroscopic aerosol. In pursuit of an effective IR wavelength screen and an increased understanding of the particle formation mechanisms and resultant size distribution, the primary objective of this year's effort was to evaluate the influence of an energetic binder (GAP) on the performance of two pyrotechnics, one which produced a KCL aerosol, the other a mixed aerosol, the other a mixed aerosol of MgCl2 and carbon. Comparison tests were run, in Calspan's 600 cu m test chamber, in which the performance of the energetic vs. non-energetic pyrotechnics was compared in terms of mass yield, payload mass extinction coefficient, aerosol decay rate and size distribution. A secondary objective of limited scope was to investigate the potential of using IR absorbing surface active agents to coat the smoke aerosol so as to enhance the smoke's IR wavelength absorption as well as inhibit subsequent aerosol evaporation upon exposure to decreasing humidity.

  8. [Uniform analyzes of drugs in urine needed for rule of law].

    PubMed

    Hansson, Therese; Helander, Anders; Beck, Olof; Elmgren, Anders; Kugelberg, Fredrik; Kronstrand, Robert

    2015-09-22

    Drugs of abuse testing is used in various areas of society for detection and follow-up of drug use. In routine laboratory drug testing, immunoassays are employed for initial screening of specimens to indicate the presence of drugs. To confirm a positive screening test, a secondary analysis by mass spectrometry is performed. The "cut-off" is the pre-defined concentration threshold of a drug or drug metabolite above which the sample is considered positive. A reading below this level implies a negative test result. Swedish drug testing laboratories currently employ varying cut-offs to distinguish between a positive and a negative test result. Because a positive drug test may have serious legal consequences to the individual, it is of importance that testing is performed and judged equally, regardless of where it is performed. A national harmonization of cut-offs is therefore warranted. Based on data from four major Swedish drug testing laboratories, and considering the recommendations in international guidelines, a proposal for national harmonization of urine cut-offs for the most common set of drugs of abuse is presented.

  9. Triglyceride-based screening tests fail to recognize cardiometabolic disease in African immigrant and African-American men.

    PubMed

    Yu, Sophia S K; Ramsey, Natalie L M; Castillo, Darleen C; Ricks, Madia; Sumner, Anne E

    2013-02-01

    The prevalence of cardiometabolic disease in Africa now rivals that of Western nations. Therefore, screening programs that lead to effective prevention of cardiometabolic disease in Africans is imperative. Most screening tests for cardiometabolic disease use triglyceride (TG) levels as a criterion. However, the failure rate of TG-based screening tests in African Americans is high. In Africans, the efficacy of TG-based screening tests is unknown. Our goal was to determine the association between hypertriglyceridemia (TG ≥150 mg/dL) and cardiometabolic disease in African and African-American men. This was a cross-sectional study of 155 men (80 African immigrants, 75 African Americans) [age, 35±9 years, mean±standard deviation (SD), body mass index (BMI) 28.5±5.2 kg/m(2)] who self-identified as healthy. Lipid profiles were performed. Glucose tolerance and insulin resistance was determined by oral glucose tolerance tests (OGTT) and the insulin sensitivity index (S(I)), respectively. Cardiometabolic disease was defined by four possible subtypes--prediabetes, diabetes, insulin resistance, or metabolic triad [hyperinsulinemia, hyperapolipoprotein B, small low-density lipoprotein (LDL) particles]. TG levels were higher in men with cardiometabolic disease than without (88±43 versus 61±26 mg/dL, P<0.01). However, <10% of men with cardiometabolic disease had TG ≥150 mg/dL. Even within each cardiometabolic disease subtype, the prevalence of TG ≥150 mg/dL was <10%. Furthermore, TG levels in the 5% of men identified by OGTT as diabetic were ≤100 mg/dL (mean 71±24, range 45-100 mg/dL). Hypertriglyceridemia is a poor marker of cardiometabolic disease in men of African descent. Therefore TG-based screening tests fail to identify both African immigrants and African-American men with cardiometabolic disease. As a consequence, the opportunity for early intervention and prevention is lost.

  10. Urinary Glucose Screening for Early Detection of Asymptomatic Type 2 Diabetes in Jeonbuk Province Korean Schoolchildren.

    PubMed

    Kim, Min Sun; Lee, Dae Yeol

    2017-06-01

    This study aimed to investigate the prevalence of glucosuria and the characteristics of diabetes in schoolchildren as detected by a school urine glucose screening program implemented from 2010 to 2013 in the Jeonbuk province area of Korea. A total of 110 children without known diabetes were analyzed. They were checked with an oral glucose tolerance test (OGTT) with other laboratory tests and their clinical data were collected. A total of 707,238 schoolchildren from a school population of 1,064,999 were screened for glucosuria. In total, over a 4-year period, 545 schoolchildren (0.077%) were positive for glucosuria on the second urine test. The prevalence of glucosuria was more common among middle and high schoolchildren than among elementary schoolchildren. Among 110 students who completed the OGTT to confirm diabetes, 40 were diagnosed with diabetes mellitus (DM); 39 children, type 2 diabetes mellitus (T2DM) and 1 child, slowly progressive insulin dependent diabetes mellitus (SPIDDM). The mean annual incidence of diabetes was 5.6 per 100,000 schoolchildren and adolescents. The subjects with diabetes diagnosed through the urine screening test showed minimal or no symptoms of diabetes. The students with diabetes were more likely to be woman and obese, and they have a higher body mass index, higher cholesterol, triglyceride, insulin, C-peptide, and fasting glucosuria values than the students with normal glucose tolerance. We identified 40 new cases of diabetes in the Korean schoolchildren with asymptomatic glucosuria on urine glucose screening. This finding shows that school urine glucose screening is a feasible and simple method for early detection of asymptomatic T2DM. © 2017 The Korean Academy of Medical Sciences.

  11. Urinary Glucose Screening for Early Detection of Asymptomatic Type 2 Diabetes in Jeonbuk Province Korean Schoolchildren

    PubMed Central

    2017-01-01

    This study aimed to investigate the prevalence of glucosuria and the characteristics of diabetes in schoolchildren as detected by a school urine glucose screening program implemented from 2010 to 2013 in the Jeonbuk province area of Korea. A total of 110 children without known diabetes were analyzed. They were checked with an oral glucose tolerance test (OGTT) with other laboratory tests and their clinical data were collected. A total of 707,238 schoolchildren from a school population of 1,064,999 were screened for glucosuria. In total, over a 4-year period, 545 schoolchildren (0.077%) were positive for glucosuria on the second urine test. The prevalence of glucosuria was more common among middle and high schoolchildren than among elementary schoolchildren. Among 110 students who completed the OGTT to confirm diabetes, 40 were diagnosed with diabetes mellitus (DM); 39 children, type 2 diabetes mellitus (T2DM) and 1 child, slowly progressive insulin dependent diabetes mellitus (SPIDDM). The mean annual incidence of diabetes was 5.6 per 100,000 schoolchildren and adolescents. The subjects with diabetes diagnosed through the urine screening test showed minimal or no symptoms of diabetes. The students with diabetes were more likely to be woman and obese, and they have a higher body mass index, higher cholesterol, triglyceride, insulin, C-peptide, and fasting glucosuria values than the students with normal glucose tolerance. We identified 40 new cases of diabetes in the Korean schoolchildren with asymptomatic glucosuria on urine glucose screening. This finding shows that school urine glucose screening is a feasible and simple method for early detection of asymptomatic T2DM. PMID:28480657

  12. Validation of the Drug Abuse Screening Test (DAST-10): A study on illicit drug use among Chinese pregnant women.

    PubMed

    Lam, Lap Po; Leung, Wing Cheong; Ip, Patrick; Chow, Chun Bong; Chan, Mei Fung; Ng, Judy Wai Ying; Sing, Chu; Lam, Ying Hoo; Mak, Wing Lai Tony; Chow, Kam Ming; Chin, Robert Kien Howe

    2015-06-19

    We assessed the Chinese version of the Drug Abuse Screening Test (DAST-10) for identifying illicit drug use during pregnancy among Chinese population. Chinese pregnant women attending their first antenatal visit or their first unbooked visit to the maternity ward were recruited during a 4-month study period in 2011. The participants completed self-administered questionnaires on demographic information, a single question on illicit drug use during pregnancy and the DAST-10. Urine samples screened positive by the urine Point-of-Care Test were confirmed by gas chromatography-mass spectrometry. DAST-10 performance was compared with three different gold standards: urinalysis, self-reported drug use, and evidence of drug use by urinalysis or self-report. 1214 Chinese pregnant women participated in the study and 1085 complete DAST-10 forms were collected. Women who had used illicit drugs had significantly different DAST-10 scores than those who had not. The sensitivity of DAST-10 for identify illicit drug use in pregnant women ranged from 79.2% to 33.3% and specificity ranged from 67.7% to 99.7% using cut-off scores from ≥ 1 to ≥ 3. The ~ 80% sensitivity of DAST-10 using a cut-off score of ≥ 1 should be sufficient for screening of illicit drug use in Chinese pregnant women, but validation tests for drug use are needed.

  13. Native State Mass Spectrometry, Surface Plasmon Resonance, and X-ray Crystallography Correlate Strongly as a Fragment Screening Combination.

    PubMed

    Woods, Lucy A; Dolezal, Olan; Ren, Bin; Ryan, John H; Peat, Thomas S; Poulsen, Sally-Ann

    2016-03-10

    Fragment-based drug discovery (FBDD) is contingent on the development of analytical methods to identify weak protein-fragment noncovalent interactions. Herein we have combined an underutilized fragment screening method, native state mass spectrometry, together with two proven and popular fragment screening methods, surface plasmon resonance and X-ray crystallography, in a fragment screening campaign against human carbonic anhydrase II (CA II). In an initial fragment screen against a 720-member fragment library (the "CSIRO Fragment Library") seven CA II binding fragments, including a selection of nonclassical CA II binding chemotypes, were identified. A further 70 compounds that comprised the initial hit chemotypes were subsequently sourced from the full CSIRO compound collection and screened. The fragment results were extremely well correlated across the three methods. Our findings demonstrate that there is a tremendous opportunity to apply native state mass spectrometry as a complementary fragment screening method to accelerate drug discovery.

  14. Patterns of colorectal cancer screening uptake in newly-eligible men and women

    PubMed Central

    Wernli, Karen J.; Hubbard, Rebecca A.; Johnson, Eric; Chubak, Jessica; Kamineni, Aruna; Green, Beverly B.; Rutter, Carolyn M.

    2014-01-01

    Background We describe patterns of colorectal cancer screening uptake in a U.S. insured population as individuals become newly-eligible for screening at age 50 and assess temporal trends and patient characteristics with screening uptake. Methods We identified a cohort of 81,223 men and women who were members of Group Health and turned 50 years old from 1996 – 2010. We ascertained receipt of colorectal cancer screening within five years. Time to screening was estimated by year of cohort entry using cumulative incidence curves and Cox proportional hazards models estimated patient characteristics associated with screening uptake. Results Stool-based screening tests were the most common, 72% of first screening tests. The proportion of individuals initiating colorectal cancer screening via colonoscopy increased from 8% in 1996–98 to 33% in 2008–10. Patient factors associated with increased colorectal cancer screening were: turning 50 more recently (2008–10) (p-trend<0.0001) or Asian race (HR=1.14, 95% CI 1.10–1.19). Patient factors associated with decreased screening were: being a woman (HR=0.70, 95% CI 0.68–0.72), Native American (HR=0.68, 95% CI 0.60–0.78) or Pacific Islander race (HR=0.82, 95% CI 0.72–0.95), and having prevalent diabetes (HR=0.78, 95% CI 0.75–0.82) and higher body mass index (p-trend<0.0001). Conclusions Patient characteristics associated with initiation of colorectal cancer screening in a newly-eligible population are similar to characteristics associated with overall screening participation in all age-eligible adults. Our results identify patient populations to target in outreach programs. Impact Disparities in receipt of colorectal cancer screening are evident from onset of an age-eligible cohort, identifying key groups for future interventions for screening. PMID:24793956

  15. [Multi-residue method for screening of pesticides in crops by liquid chromatography with tandem mass spectrometry].

    PubMed

    Tanizawa, Haruna; Shima, Mikie; Ikehara, Chieko; Kobata, Masakazu; Sato, Motoaki

    2005-10-01

    A simple and rapid method was developed for the screening of 82 pesticides/metabolites in a wide variety of crops, using solid-phase extraction and liquid chromatography with tandem mass spectrometry (LC/MS/MS). After extraction with methanol, the filtered extracts were made up to 100 mL and a 2 mL aliquot was subjected to solid-phase extraction. Co-extractives were removed with a C18 mini-column, while pesticides were retained on 3 kinds of mini-columns (HLB, SAX, activated carbon), and then eluted with acetonitrile. Analysis was performed by LC/MS/MS, and MS acquisition parameters were established in positive and negative ESI modes. The utility of the method was demonstrated by the analysis of 6 crops (carrot, cabbage, onion, spinach, lemon, brown rice) and one mixed vegetable juice. Of 82 compounds tested, 75 in carrot and 62 in lemon were obtained with recoveries ranging from 70-120%. For all samples tested, 75 compounds could be obtained with recoveries of over 50%, and the detection limits of most compounds were lower than 0.01 microg/g. This method provides acceptable performance for analysis of these 75 compounds. Further, by using aliquots of the extracts with small-scale mini-columns, purified samples could be obtained. This proposed method with small matrix effects, is effective and suitable for screening of multiple residual pesticides by using LC/MS/MS.

  16. Detection and identification of drugs and toxicants in human body fluids by liquid chromatography-tandem mass spectrometry under data-dependent acquisition control and automated database search.

    PubMed

    Oberacher, Herbert; Schubert, Birthe; Libiseller, Kathrin; Schweissgut, Anna

    2013-04-03

    Systematic toxicological analysis (STA) is aimed at detecting and identifying all substances of toxicological relevance (i.e. drugs, drugs of abuse, poisons and/or their metabolites) in biological material. Particularly, gas chromatography-mass spectrometry (GC/MS) represents a competent and commonly applied screening and confirmation tool. Herein, we present an untargeted liquid chromatography-tandem mass spectrometry (LC/MS/MS) assay aimed to complement existing GC/MS screening for the detection and identification of drugs in blood, plasma and urine samples. Solid-phase extraction was accomplished on mixed-mode cartridges. LC was based on gradient elution in a miniaturized C18 column. High resolution electrospray ionization-MS/MS in positive ion mode with data-dependent acquisition control was used to generate tandem mass spectral information that enabled compound identification via automated library search in the "Wiley Registry of Tandem Mass Spectral Data, MSforID". Fitness of the developed LC/MS/MS method for application in STA in terms of selectivity, detection capability and reliability of identification (sensitivity/specificity) was demonstrated with blank samples, certified reference materials, proficiency test samples, and authentic casework samples. Copyright © 2013 Elsevier B.V. All rights reserved.

  17. The impact of sociodemographic factors and PSA screening among low-income Black and White men: data from the Southern Community Cohort Study.

    PubMed

    Moses, K A; Zhao, Z; Bi, Y; Acquaye, J; Holmes, A; Blot, W J; Fowke, J H

    2017-12-01

    Variation in PSA screening is a potential source of disparity in prostate cancer survival, particularly among underserved populations. We sought to examine the impact of race and socioeconomic status (SES) on receipt of PSA testing among low-income men. Black (n=22 167) and White (n=9588) men aged ⩾40 years completed a baseline questionnaire from 2002 to 2009 as part of the Southern Community Cohort Study. Men reported whether they had ever received PSA testing and had testing within the prior 12 months. To evaluate the associations between SES, race and receipt of PSA testing, odds ratios (ORs) and 95% confidence intervals (CIs) were estimated from the multivariable logistic models where age, household income, insurance status, marital status, body mass index and educational level were adjusted. Black men were younger, had a lower income, less attained education and were more likely to be unmarried and uninsured (all P<0.001). Percentages of men having ever received PSA testing rose from <40% under the age of 45 years to ~90% above the age of 65 years, with Whites >50 more likely than Blacks to have received testing. Lower SES was significantly associated with less receipt of PSA testing in both groups. After adjustment for SES, White men had significantly lower odds of PSA testing (OR 0.81; 95% CI: 0.76-0.87). Greater PSA testing among White than Black men over the age of 50 years in this low-income population appears to be mainly a consequence of SES. Strategies for PSA screening may benefit from tailoring to the social circumstances of the men being screened.

  18. Forensic electrochemistry: indirect electrochemical sensing of the components of the new psychoactive substance "Synthacaine".

    PubMed

    Cumba, Loanda R; Kolliopoulos, Athanasios V; Smith, Jamie P; Thompson, Paul D; Evans, Peter R; Sutcliffe, Oliver B; do Carmo, Devaney R; Banks, Craig E

    2015-08-21

    "Synthacaine" is a New Psychoactive Substance which is, due to its inherent psychoactive properties, reported to imitate the effects of cocaine and is therefore consequently branded as "legal cocaine". The only analytical approach reported to date for the sensing of "Synthacaine" is mass spectrometry. In this paper, we explore and evaluate a range of potential analytical techniques for its quantification and potential use in the field screening "Synthacaine" using Raman spectroscopy, presumptive (colour) testing, High Performance Liquid Chromatography (HPLC) and electrochemistry. HPLC analysis of street samples reveals that "Synthacaine" comprises a mixture of methiopropamine (MPA) and 2-aminoindane (2-AI). Raman spectroscopy and presumptive (colour) tests, the Marquis, Mandelin, Simon's and Robadope test, are evaluated towards a potential in-the-field screening approach but are found to not be able to discriminate between the two when they are both present in the same sample, as is the case in the real street samples. We report for the first time a novel indirect electrochemical protocol for the sensing of MPA and 2-AI which is independently validated in street samples with HPLC. This novel electrochemical approach based upon one-shot disposable cost effective screen-printed graphite macroelectrodes holds potential for in-the-field screening for "Synthacaine".

  19. Pilot proficiency testing study for second tier congenital adrenal hyperplasia newborn screening.

    PubMed

    De Jesús, Víctor R; Simms, David A; Schiffer, Jarad; Kennedy, Meredith; Mei, Joanne V; Hannon, W Harry

    2010-11-11

    Congenital adrenal hyperplasia (CAH) is caused by inherited defects in steroid biosynthesis. The Newborn Screening Quality Assurance Program (NSQAP) initiated a pilot, dried-blood spot (DBS)-based proficiency testing program designed to investigate materials and laboratory performance for second tier CAH screening by tandem mass spectrometry (MS/MS). The ratio of 17-α-hydroxyprogesterone (17-OHP), androstenedione (4-AD) and cortisol is used as an indicator of CAH in laboratory protocols for second tier analysis of DBS specimens. DBS prepared by NSQAP contained a range of steroid concentrations resulting in different clinical ratios. Laboratories received blind-coded DBS specimens and reported results to NSQAP for evaluation. Quantitative values reported by participants for 17-OHP, 4-AD, and cortisol, reflected small differences in their analytical methods. Average quantitative values for 17-OHP increased from 81% to 107% recovery over the 3.5-year period; cortisol recoveries increased from 61.9% to 89.5%; and 4-AD recoveries decreased from 184% to 68%. Laboratory participation in the CAH second tier proficiency testing program has resulted in improved analyte recoveries and enhanced sample preparation methodologies. NSQAP services for the second tier CAH analysis in DBS demonstrate the need for surveillance to ensure harmonization and continuous improvements, and to achieve sustained high-performance of newborn screening laboratories worldwide. Published by Elsevier B.V.

  20. Detection of Stimulants and Narcotics by Liquid Chromatography-Tandem Mass Spectrometry and Gas Chromatography-Mass Spectrometry for Sports Doping Control.

    PubMed

    Ahrens, Brian D; Kucherova, Yulia; Butch, Anthony W

    2016-01-01

    Sports drug testing laboratories are required to detect several classes of compounds that are prohibited at all times, which include anabolic agents, peptide hormones, growth factors, beta-2 agonists, hormones and metabolic modulators, and diuretics/masking agents. Other classes of compounds such as stimulants, narcotics, cannabinoids, and glucocorticoids are also prohibited, but only when an athlete is in competition. A single class of compounds can contain a large number of prohibited substances and all of the compounds should be detected by the testing procedure. Since there are almost 70 stimulants on the prohibited list it can be a challenge to develop a single screening method that will optimally detect all the compounds. We describe a combined liquid chromatography-tandem mass spectrometry (LC-MS/MS) and gas chromatography-mass spectrometry (GC-MS) testing method for detection of all the stimulants and narcotics on the World Anti-Doping Agency prohibited list. Urine for LC-MS/MS testing does not require sample pretreatment and is a direct dilute and shoot method. Urine samples for the GC-MS method require a liquid-liquid extraction followed by derivatization with trifluoroacetic anhydride.

  1. [Generalized neonatal screening based on laboratory tests].

    PubMed

    Ardaillou, Raymond; Le Gall, Jean-Yves

    2006-11-01

    Implementation of a generalized screening program for neonatal diseases must obey precise rules. The disease must be severe, recognizable at an early stage, amenable to an effective treatment, detectable with a non expensive and widely applicable test; it must also be a significant public health problem. Subjects with positive results must be offered immediate treatment or prevention. All screening programs must be regularly evaluated. In France, since 1978, a national screening program has been organized by a private association ("Association française pour le dépistage et la prévention des handicaps de l'enfant") and supervised by the "Caisse nationale d'assurance maladie" and "Direction Générale de la Sante". Five diseases are now included in the screening program: phenylketonuria, hypothyroidism, congenital adrenal hyperplasia, cystic fibrosis and sickle cell disease (the latter only in at-risk newborns). Toxoplasmosis is a particular problem because only the children of mothers who were not tested during the pregnancy or who seroconverted are screened. Neonatal screening for phenylketonuria and hypothyrodism is unanimously recommended. Screening for congenital adrenal hyperplasia is approved in most countries. Cases of sickle cell disease and cystic fibrosis are more complex because--not all children who carry the mutations develop severe forms;--there is no curative treatment;--parents may become anxious, even though the phenotype is sometimes mild or even asymptomatic. Supporters of screening stress the benefits of early diagnosis (which extends the life expectancy of these children, particularly in the case of sickle cell disease), the fact that it opens up the possibility of prenatal screening of future pregnancies, and the utility of informing heterozygous carriers identified by familial screening. Neonatal screening for other diseases is under discussion. Indeed, technical advances such as tandem mass spectrometry make it possible to detect about 50 diseases in a single run. In addition to issues of cost and organization, any increase in the number of screened diseases will raise ethical problems, such as how to inform parents of an incurable disease, a late-onset disease, or an entirely asymptomatic disorder. It is unanimously agreed that only Mendelian diseases should be screened for (excluding genetic polymorphisms). Analysis of the present situation suggests the following changes:--guidelines for choosing new diseases for neonatal screening should be updated;--all new screening programs should be tested locally before nationwide implementation;--an evaluation committee of paediatricians and epidemiologists should be created, and the children's long-term outcome should be studied;--the conditions in which heterozygous carriers are informed after familial investigations need to be precisely defined;--blood samples should be banked for epidemiological studies.

  2. Suspected-target pesticide screening using gas chromatography-quadrupole time-of-flight mass spectrometry with high resolution deconvolution and retention index/mass spectrum library.

    PubMed

    Zhang, Fang; Wang, Haoyang; Zhang, Li; Zhang, Jing; Fan, Ruojing; Yu, Chongtian; Wang, Wenwen; Guo, Yinlong

    2014-10-01

    A strategy for suspected-target screening of pesticide residues in complicated matrices was exploited using gas chromatography in combination with hybrid quadrupole time-of-flight mass spectrometry (GC-QTOF MS). The screening workflow followed three key steps of, initial detection, preliminary identification, and final confirmation. The initial detection of components in a matrix was done by a high resolution mass spectrum deconvolution; the preliminary identification of suspected pesticides was based on a special retention index/mass spectrum (RI/MS) library that contained both the first-stage mass spectra (MS(1) spectra) and retention indices; and the final confirmation was accomplished by accurate mass measurements of representative ions with their response ratios from the MS(1) spectra or representative product ions from the second-stage mass spectra (MS(2) spectra). To evaluate the applicability of the workflow in real samples, three matrices of apple, spinach, and scallion, each spiked with 165 test pesticides in a set of concentrations, were selected as the models. The results showed that the use of high-resolution TOF enabled effective extractions of spectra from noisy chromatograms, which was based on a narrow mass window (5 mDa) and suspected-target compounds identified by the similarity match of deconvoluted full mass spectra and filtering of linear RIs. On average, over 74% of pesticides at 50 ng/mL could be identified using deconvolution and the RI/MS library. Over 80% of pesticides at 5 ng/mL or lower concentrations could be confirmed in each matrix using at least two representative ions with their response ratios from the MS(1) spectra. In addition, the application of product ion spectra was capable of confirming suspected pesticides with specificity for some pesticides in complicated matrices. In conclusion, GC-QTOF MS combined with the RI/MS library seems to be one of the most efficient tools for the analysis of suspected-target pesticide residues in complicated matrices. Copyright © 2014 Elsevier B.V. All rights reserved.

  3. Weak cation exchange magnetic beads coupled with matrix-assisted laser desorption ionization-time of flight-mass spectrometry in screening serum protein markers in osteopenia.

    PubMed

    He, Wei-Tao; Liang, Bo-Cheng; Shi, Zhen-Yu; Li, Xu-Yun; Li, Chun-Wen; Shi, Xiao-Lin

    2016-01-01

    The present study aimed at investigating the weak cation magnetic separation technology and matrix-assisted laser desorption ionization-time of flight-mass spectrometry (MALDI-TOF-MS) in screening serum protein markers of osteopenia from ten postmenopausal women and ten postmenopausal women without osteopenia as control group, to find a new method for screening biomarkers and establishing a diagnostic model for primary type I osteoporosis. Serum samples were collected from postmenopausal women with osteopenia and postmenopausal women with normal bone mass. Proteins were extracted from serum samples by weak cation exchange magnetic beads technology, and mass spectra acquisition was done by MALDI-TOF-MS. The visualization and comparison of data sets, statistical peak evaluation, model recognition, and discovery of biomarker candidates were handled by the proteinchip data analysis system software(ZJU-PDAS). The diagnostic models were established using genetic arithmetic based support vector machine (SVM). The SVM result with the highest Youden Index was selected as the model. Combinatorial Peaks having the highest accuracy in distinguishing different samples were selected as potential biomarker. From the two group serum samples, a total of 133 differential features were selected. Ten features with significant intensity differences were screened. In the pair-wise comparisons, processing of MALDI-TOF spectra resulted in the identification of ten differential features between postmenopausal women with osteopenia and postmenopausal women with normal bone mass. The difference of features by Youden index showed that the highest features had a mass to charge ratio of 1699 and 3038 Da. A diagnosis model was established with these two peaks as the candidate marker, and the specificity of the model is 100 %, the sensitivity was 90 % by leave-one-out cross validation test. The two groups of specimens in SVM results on the scatter plot could be clearly distinguished. The peak with m/z 3038 in the SVM model was suggested as Secretin by TagIdent tool. To provide further validation, the secretin levels in serum were analyzed using enzyme-linked immunosorbent assays that is a competitive inhibition enzyme immunoassay technique for the in vitro quantitative measurement of secretin in human serum.

  4. Evaluation of a New Ensemble Learning Framework for Mass Classification in Mammograms.

    PubMed

    Rahmani Seryasat, Omid; Haddadnia, Javad

    2018-06-01

    Mammography is the most common screening method for diagnosis of breast cancer. In this study, a computer-aided system for diagnosis of benignity and malignity of the masses was implemented in mammogram images. In the computer aided diagnosis system, we first reduce the noise in the mammograms using an effective noise removal technique. After the noise removal, the mass in the region of interest must be segmented and this segmentation is done using a deformable model. After the mass segmentation, a number of features are extracted from it. These features include: features of the mass shape and border, tissue properties, and the fractal dimension. After extracting a large number of features, a proper subset must be chosen from among them. In this study, we make use of a new method on the basis of a genetic algorithm for selection of a proper set of features. After determining the proper features, a classifier is trained. To classify the samples, a new architecture for combination of the classifiers is proposed. In this architecture, easy and difficult samples are identified and trained using different classifiers. Finally, the proposed mass diagnosis system was also tested on mini-Mammographic Image Analysis Society and digital database for screening mammography databases. The obtained results indicate that the proposed system can compete with the state-of-the-art methods in terms of accuracy. Copyright © 2017 Elsevier Inc. All rights reserved.

  5. Validation of a rapid lateral flow test for the simultaneous determination of β-lactam drugs and flunixin in raw milk.

    PubMed

    Douglas, David; Banaszewski, Katie; Juskelis, Rima; Al-Taher, Fadwa; Chen, Yang; Cappozzo, Jack; McRobbie, Lindsay; Salter, Robert S

    2012-07-01

    β-Lactam antibiotics are the most commonly used drugs on dairy farms. β-Lactam residues in milk are kept out of the human milk supply with good agricultural practices and mandatory truck screening performed by the dairy industry under Appendix N of the Pasteurized Milk Ordinance. Flunixin, a nonsteroidal and anti-inflammatory drug, appears in dairy cattle tissue residues with a frequency similar to the occurrence of penicillin G. This creates concern that flunixin residues could be in milk and would go undetected under current milk screening programs. A single test that combines mandatory β-lactam screening with voluntary flunixin screening is an economical approach for monitoring and controlling for potential flunixin or 5-hydroxyflunixin, the primary flunixin metabolite marker in milk. The objective of this study was to validate a β-lactam and flunixin rapid lateral flow test (LFT) and compare the results obtained with a liquid chromatography-triple quadrupole tandem mass spectrometry (LC-MS/MS) method for the simultaneous determination of flunixin and 5-hydroxyflunixin in raw milk with a limit of detection of , 1 ppb, equivalent to 1 ng/ml. Using the LFT, three combined manufactured lots of test strips detected penicillin G at 2.0 ppb, ampicillin at 6.8 ppb, amoxicillin at 5.9 ppb, cephapirin at 13.4 ppb, ceftiofur (total metabolites) at 63 ppb, and 5-hydroxyflunixin at 1.9 ppb at least 90% of the time with 95% confidence. The LFT also detected incurred flunixin milk samples that were analyzed with the LC-MS/MS and diluted to tolerance in raw milk. The detection levels for the LFT are lower than the U.S. safe levels or tolerances and qualify the test to be used in compliance with U.S. milk screening programs.

  6. Survey of South African fruit juices using a fast screening HILIC-MS method.

    PubMed

    Stander, Marietjie A; Kühn, Wernich; Hiten, Nicholas F

    2013-01-01

    Adulteration of fruit juices--by the addition of sugar or other less expensive fruit juices as well as preservatives, artificial sweeteners and colours--was tested for by using a developed screening method. The method employs hydrophilic interaction liquid chromatography-mass spectrometry (HILIC-MS) using electrospray ionisation in the negative mode and ultraviolet light detection. Different fruit juices can be differentiated by the content of marker compounds like sorbitol, certain phenolic molecules and their saccharide profile. This method was used to test 46 fruit juice samples from the retail market as well as 12 control samples. The study focused on the main types of fruit juices consumed on the South African market including apple, orange, grape and blends of these juices with other fruits like mango, pear and guava. Overall, the 46 samples tested mostly agreed with label claims. One grape juice sample was adulterated, probably with apple juice. Natamycin above the legal limits was found in two samples. In addition, two samples contained natamycin and one sample benzoate without it being indicated on the label. The method is well suited as a quick screening method for fruit juice adulteration and if used routinely would reduce fruit juice adulteration without the cost of the current array of tests needed for authenticity testing.

  7. Screening tests for the rapid detection of diarrhetic shellfish toxins in Washington State.

    PubMed

    Eberhart, Bich-Thuy L; Moore, Leslie K; Harrington, Neil; Adams, Nicolaus G; Borchert, Jerry; Trainer, Vera L

    2013-09-30

    The illness of three people due to diarrhetic shellfish poisoning (DSP) following their ingestion of recreationally harvested mussels from Sequim Bay State Park in the summer of 2011, resulted in intensified monitoring for diarrhetic shellfish toxins (DSTs) in Washington State. Rapid testing at remote sites was proposed as a means to provide early warning of DST events in order to protect human health and allow growers to test "pre-harvest" shellfish samples, thereby preventing harvest of toxic product that would later be destroyed or recalled. Tissue homogenates from several shellfish species collected from two sites in Sequim Bay, WA in the summer 2012, as well as other sites throughout Puget Sound, were analyzed using three rapid screening methods: a lateral flow antibody-based test strip (Jellett Rapid Test), an enzyme-linked immunosorbent assay (ELISA) and a protein phosphatase 2A inhibition assay (PP2A). The results were compared to the standard regulatory method of liquid chromatography coupled with tandem mass spectroscopy (LC-MS/MS). The Jellett Rapid Test for DSP gave an unacceptable number of false negatives due to incomplete extraction of DSTs using the manufacturer's recommended method while the ELISA antibody had low cross-reactivity with dinophysistoxin-1, the major toxin isomer in shellfish from the region. The PP2A test showed the greatest promise as a screening tool for Washington State shellfish harvesters.

  8. Screening Tests for the Rapid Detection of Diarrhetic Shellfish Toxins in Washington State

    PubMed Central

    Eberhart, Bich-Thuy L.; Moore, Leslie K.; Harrington, Neil; Adams, Nicolaus G.; Borchert, Jerry; Trainer, Vera L.

    2013-01-01

    The illness of three people due to diarrhetic shellfish poisoning (DSP) following their ingestion of recreationally harvested mussels from Sequim Bay State Park in the summer of 2011, resulted in intensified monitoring for diarrhetic shellfish toxins (DSTs) in Washington State. Rapid testing at remote sites was proposed as a means to provide early warning of DST events in order to protect human health and allow growers to test “pre-harvest” shellfish samples, thereby preventing harvest of toxic product that would later be destroyed or recalled. Tissue homogenates from several shellfish species collected from two sites in Sequim Bay, WA in the summer 2012, as well as other sites throughout Puget Sound, were analyzed using three rapid screening methods: a lateral flow antibody-based test strip (Jellett Rapid Test), an enzyme-linked immunosorbent assay (ELISA) and a protein phosphatase 2A inhibition assay (PP2A). The results were compared to the standard regulatory method of liquid chromatography coupled with tandem mass spectroscopy (LC-MS/MS). The Jellett Rapid Test for DSP gave an unacceptable number of false negatives due to incomplete extraction of DSTs using the manufacturer’s recommended method while the ELISA antibody had low cross-reactivity with dinophysistoxin-1, the major toxin isomer in shellfish from the region. The PP2A test showed the greatest promise as a screening tool for Washington State shellfish harvesters. PMID:24084788

  9. Prostate cell membrane chromatography-liquid chromatography-mass spectrometry for screening of active constituents from Uncaria rhynchophylla.

    PubMed

    He, Jianyu; Han, Shengli; Yang, Fangfang; Zhou, Nan; Wang, Sicen

    2013-01-01

    Uncaria rhynchophylla is a traditional Chinese medicinal herb used to treat hypertension and convulsive disorders such as epilepsy. Rat prostate cell membrane chromatography combined with liquid chromatography-mass spectrometry (LC-MS) was used to identify active constituents from U. rhynchophylla extracts. Four compounds (corynoxeine, isorhynchophylline, isocorynoxeine and rhynchophylline) were discovered. Competitive binding assay results indicated that the four compounds were in direct competition at a single common binding site and interacted with α1A adrenergic receptors (α1A-AR) in a manner similar to tamsulosin. Affinity constant values of the four compounds binding with α1A-AR were also measured using rat prostate cell membrane chromatography (CMC). Finally, their pharmacodynamic effects were tested on rat caudal arteries. This CMC combined LC-MS system offers a means of drug discovery by screening natural medicinal herbs for new pharmacologically active molecules targeting specific receptors.

  10. Computer-aided diagnosis workstation and network system for chest diagnosis based on multislice CT images

    NASA Astrophysics Data System (ADS)

    Satoh, Hitoshi; Niki, Noboru; Mori, Kiyoshi; Eguchi, Kenji; Kaneko, Masahiro; Kakinuma, Ryutarou; Moriyama, Noriyuki; Ohmatsu, Hironobu; Masuda, Hideo; Machida, Suguru

    2007-03-01

    Multislice CT scanner advanced remarkably at the speed at which the chest CT images were acquired for mass screening. Mass screening based on multislice CT images requires a considerable number of images to be read. It is this time-consuming step that makes the use of helical CT for mass screening impractical at present. To overcome this problem, we have provided diagnostic assistance methods to medical screening specialists by developing a lung cancer screening algorithm that automatically detects suspected lung cancers in helical CT images and a coronary artery calcification screening algorithm that automatically detects suspected coronary artery calcification. Moreover, we have provided diagnostic assistance methods to medical screening specialists by using a lung cancer screening algorithm built into mobile helical CT scanner for the lung cancer mass screening done in the region without the hospital. We also have developed electronic medical recording system and prototype internet system for the community health in two or more regions by using the Virtual Private Network router and Biometric fingerprint authentication system and Biometric face authentication system for safety of medical information. Based on these diagnostic assistance methods, we have now developed a new computer-aided workstation and database that can display suspected lesions three-dimensionally in a short time. This paper describes basic studies that have been conducted to evaluate this new system.

  11. Mass screening for Trypanosoma cruzi infections using the immunofluorescence, ELISA and haemagglutination tests on serum samples and on blood eluates from filter-paper.

    PubMed Central

    Zicker, F.; Smith, P. G.; Luquetti, A. O.; Oliveira, O. S.

    1990-01-01

    Methods used to diagnose Trypanosoma cruzi infection differ in their ability to discriminate between sera from infected and uninfected individuals. We compared the results of an immunofluorescence (IF) test, a haemagglutination (HA) test, and an enzyme-linked immunosorbent assay (ELISA) for the diagnosis of T. cruzi infections in a large population-based survey in central Brazil using blood eluates from filter-paper and venous blood samples. The sensitivities of the tests on eluates, compared with results on serum samples, were low: ELISA (78.1%), IF (69.2%) and HA (64.6%). The level of agreement between the tests on eluates was very poor, with the best co-positivity for IF and ELISA. Both the positive and negative predictive values of the three tests on eluates were similar (around 96%) to those for sera. Higher co-positivity values were obtained for the three tests on sera. The implications of these results are discussed in relation to blood screening, routine medical practice, sero-epidemiological surveys, and the follow-up of patients admitted to therapeutic trials. PMID:2119903

  12. Mass screening for Trypanosoma cruzi infections using the immunofluorescence, ELISA and haemagglutination tests on serum samples and on blood eluates from filter-paper.

    PubMed

    Zicker, F; Smith, P G; Luquetti, A O; Oliveira, O S

    1990-01-01

    Methods used to diagnose Trypanosoma cruzi infection differ in their ability to discriminate between sera from infected and uninfected individuals. We compared the results of an immunofluorescence (IF) test, a haemagglutination (HA) test, and an enzyme-linked immunosorbent assay (ELISA) for the diagnosis of T. cruzi infections in a large population-based survey in central Brazil using blood eluates from filter-paper and venous blood samples. The sensitivities of the tests on eluates, compared with results on serum samples, were low: ELISA (78.1%), IF (69.2%) and HA (64.6%). The level of agreement between the tests on eluates was very poor, with the best co-positivity for IF and ELISA. Both the positive and negative predictive values of the three tests on eluates were similar (around 96%) to those for sera. Higher co-positivity values were obtained for the three tests on sera. The implications of these results are discussed in relation to blood screening, routine medical practice, sero-epidemiological surveys, and the follow-up of patients admitted to therapeutic trials.

  13. Role of the laboratory in the evaluation of suspected drug abuse.

    PubMed

    Gold, M S; Dackis, C A

    1986-01-01

    Despite the high incidence of substance abuse, it remains a common cause of misdiagnosis. In patients who have abused or who are currently abusing drugs, symptoms of a psychiatric illness may be mimicked by either the drug's presence or absence. The laboratory can aid in making a differential diagnosis and eliminating drugs from active consideration as a cause of psychosis, depression, mania, and personality changes. Treatment planning and prevention of serious medical consequences often rest on the accuracy of the admission drug screen. Testing is widely used to assess improvement in substance abuse in both inpatient and outpatient settings. In occupational settings, testing has been used as an early indicator that a problem exists and as a successful prevention tool. The appropriate use of analytic technology in drug abuse testing requires an understanding of available test methodologies. These include drug screens by thin-layer chromatography, comprehensive testing using enzyme immunoassay, and computer-assisted gas chromatography-mass spectrometry (GC-MS). Testing for specific drugs considered likely causes or precipitants of "psychiatric" complaints is available with enzyme assays, radioimmunoassay, or definitive forensic-quality testing using GC-MS.

  14. Pilot trial on separation conditions for diaper recycling.

    PubMed

    Kim, Kyung-Shin; Cho, Hee-Sun

    2017-09-01

    By utilizing laboratory-scale tests, the optimal separation conditions for diaper recycling were identified, and then, these conditions were validated by a pilot trial. In this research, we determined the mass balances derived during various processing steps and identified the most feasible procedures to use for separating each material in the output flow. The results showed that drum screening was not able to remove all the fiber and super absorbent particles (SAP) in the plastic-rich fraction and that cellulose enzyme treatment can be a good solution. To achieve better separation of fibers and SAP, slot screening followed by a cleaner is a potential option. A feasible diaper recycling process was recommended based on these results. This process involves screening and enzymatic treatment for the plastic fraction, and screening, cleaning, and thickening for the fiber fraction. Treatment procedures were also proposed for the SAP fraction and rejected materials. Copyright © 2017. Published by Elsevier Ltd.

  15. Validity of "sputtering and re-condensation" model in active screen cage plasma nitriding process

    NASA Astrophysics Data System (ADS)

    Saeed, A.; Khan, A. W.; Jan, F.; Abrar, M.; Khalid, M.; Zakaullah, M.

    2013-05-01

    The validity of "sputtering and re-condensation" model in active screen plasma nitriding for nitrogen mass transfer mechanism is investigated. The dominant species including NH, Fe-I, N2+, N-I and N2 along with Hα and Hβ lines are observed in the optical emission spectroscopy (OES) analysis. Active screen cage and dc plasma nitriding of AISI 316 stainless steel as function of treatment time is also investigated. The structure and phases composition of the nitrided layer is studied by X-ray diffraction (XRD). Surface morphology is studied by scanning electron microscopy (SEM) and hardness profile is obtained by Vicker's microhardness tester. Increasing trend in microhardness is observed in both cases but the increase in active screen plasma nitriding is about 3 times greater than that achieved by dc plasma nitriding. On the basis of metallurgical and OES observations the use of "sputtering and re-condensation" model in active screen plasma nitriding is tested.

  16. Parent Reactions to a School-Based Body Mass Index Screening Program

    ERIC Educational Resources Information Center

    Johnson, Suzanne Bennett; Pilkington, Lorri L.; Lamp, Camilla; He, Jianghua; Deeb, Larry C.

    2009-01-01

    Background: This study assessed parent reactions to school-based body mass index (BMI) screening. Methods: After a K-8 BMI screening program, parents were sent a letter detailing their child's BMI results. Approximately 50 parents were randomly selected for interview from each of 4 child weight-classification groups (overweight, at risk of…

  17. HPV genotypes and associated cervical cytological abnormalities in women from the Pearl River Delta region of Guangdong province, China: a cross-sectional study

    PubMed Central

    2014-01-01

    Background It is important to understand the specific HPV genotype distribution in screen-detected lesions. HPV Genotype is helpful for separating HPV-positive women at greater risk of cancer from those who can regress spontaneously and for preventing cervical cancer at early stage. The aim of this study was to investigate the high-risk HPV genotype distribution among cervical cytology abnormality in Pearl River Delta Region, Southern China Methods 5585 HPV-infected women were screened from 77069 women in Pearl River Delta Region. Information was obtained from 3226 screened subjects through questionnaires and personal interviews. Exfoliated cervical cells were collected by doctors for HPV test with MassARRAY (Sequenom, Sandiego, CA) technique based on the matrix-assisted laser desorption/ionization time-of flight (MALDI-TOF) mass spectrometry (MS). The ThinPrep cytology test was performed to screen for cervical cancer. Unconditional logistic was used to determine the most common HPV carcinogenic types. Results Of the 3226 HPV-positive samples tested, 1744 (54.1%) with normal cervical cytology, 1482 (45.9%) with abnormal cytology. The five most common HPV types in this study were HPV16 (20.2%), HPV52 (17.1%), HPV58 (13.2%), HPV18 (9.5%), HPV6 (7.6%). Overall, HPV16 (OR = 10.5, 95% CI: 3.7 ~ 29.6), HPV33 (OR = 9.1, 95% CI: 2.8 ~ 29.2), HPV58 (OR = 6.3, 95% CI: 2.1 ~ 18.6), HPV31 (OR = 4.5, 95% CI: 1.3 ~ 15.5), multiple genotype infection (OR = 3.0, 95% CI: 1.7 ~ 14.7), especially HPV16 and HPV33, increased the risk of cytology abnormalities. Conclusions HPV16, HPV31, HPV33, HPV58, and multiple HPV genotype infection increased the risk of cytology abnormalities in Pearl River Delta Region and might be useful for the screening, preventing, treating, and monitoring of pre-cancer lesions in southern China. PMID:25016305

  18. [Determination of cost-effective strategies in colorectal cancer screening].

    PubMed

    Dervaux, B; Eeckhoudt, L; Lebrun, T; Sailly, J C

    1992-01-01

    The object of the article is to implement particular methodologies in order to determine which strategies are cost-effective in the mass screening of colorectal cancer after a positive Hemoccult test. The first approach to be presented consists in proposing a method which enables all the admissible diagnostic strategies to be determined. The second approach enables a minimal cost function to be estimated using an adaptation of "Data Envelopment Analysis". This method proves to be particularly successful in cost-efficiency analysis, when the performance indicators are numerous and hard to aggregate. The results show that there are two cost-effective strategies after a positive Hemoccult test: coloscopy and sigmoidoscopy; they put into question the relevance of double contrast barium enema in the diagnosis of colo-rectal lesions.

  19. ASTROPHYSICS. Atom-interferometry constraints on dark energy.

    PubMed

    Hamilton, P; Jaffe, M; Haslinger, P; Simmons, Q; Müller, H; Khoury, J

    2015-08-21

    If dark energy, which drives the accelerated expansion of the universe, consists of a light scalar field, it might be detectable as a "fifth force" between normal-matter objects, in potential conflict with precision tests of gravity. Chameleon fields and other theories with screening mechanisms, however, can evade these tests by suppressing the forces in regions of high density, such as the laboratory. Using a cesium matter-wave interferometer near a spherical mass in an ultrahigh-vacuum chamber, we reduced the screening mechanism by probing the field with individual atoms rather than with bulk matter. We thereby constrained a wide class of dark energy theories, including a range of chameleon and other theories that reproduce the observed cosmic acceleration. Copyright © 2015, American Association for the Advancement of Science.

  20. Exhaled gases online measurements for esophageal cancer patients and healthy people by proton transfer reaction mass spectrometry.

    PubMed

    Zou, Xue; Zhou, Wenzhao; Lu, Yan; Shen, Chengyin; Hu, Zongtao; Wang, Hongzhi; Jiang, Haihe; Chu, Yannan

    2016-11-01

    Esophageal cancer is a prevalent malignancy. There is a considerable demand for developing a fast and noninvasive method to screen out the suspect esophageal cancer patients who may undergo further clinical diagnosis. The exhaled breathes from 29 esophageal cancer patients and 57 healthy people were directly measured using our home-made proton transfer reaction mass spectrometer (PTR-MS). Mann-Whitney U test and stepwise discriminant analysis were applied to identify the ions in the breath mass spectral data which can distinguish cancer cohort from healthy group. Receiver operating characteristics (ROC) analysis was also performed. Seven kinds of ions in the breath mass spectrum, viz., m/z 136, m/z 34, m/z 63, m/z 27, m/z 95, m/z 107 and m/z 45, have been found to distinguish between the esophageal cancer patients and healthy people with a sensitivity of 86.2% and a specificity of 89.5%, respectively. Compared with that from the healthy people, the breath mass spectra from esophageal cancer patients show that the mediant intensities of five kinds of ions were decrease and the rest two kinds of ions were increase. ROC analysis gave the area under the curve (AUC) of 0.943. This pilot study shows that the ionic characteristics of exhaled VOCs detected by PTR-MS may be used to differentiate between the esophageal cancer patients and the healthy people. Although the breath tests for more patients are needed to confirm such results, the present work indicates that the PTR-MS may be a promising method in the esophageal cancer screening. © 2016 Journal of Gastroenterology and Hepatology Foundation and John Wiley & Sons Australia, Ltd.

  1. Influence of magnetic fields on the color screening masses

    NASA Astrophysics Data System (ADS)

    Bonati, Claudio; D'Elia, Massimo; Mesiti, Michele; Negro, Francesco; Rucci, Andrea; Sanfilippo, Francesco

    2018-03-01

    We present some recent results obtained in the study of the color magnetic and electric screening masses in the QCD plasma. In particular, we discuss how the masses get modified by strong external fields which are expected to be created in physical situations such as heavy-ion collisions.

  2. Sarcopenia Screened by the SARC-F Questionnaire and Physical Performances of Elderly Women: A Cross-Sectional Study.

    PubMed

    Rolland, Yves; Dupuy, Charlotte; Abellan Van Kan, Gabor; Cesari, Matteo; Vellas, Bruno; Faruch, Marie; Dray, Cedric; de Souto Barreto, Philipe

    2017-10-01

    Screening for sarcopenia in daily practice can be challenging. Our objective was to explore whether the SARC-F questionnaire is a valid screening tool for sarcopenia (defined by the Foundation for the National Institutes of Health [FNIH] criteria). Moreover, we evaluated the physical performance of older women according to the SARC-F questionnaire. Cross-sectional study. Data from the Toulouse and Lyon EPIDémiologie de l'OStéoporose study (EPIDOS) on 3025 women living in the community (mean age: 80.5 ± 3.9 years), without a previous history of hip fracture, were assessed. The SARC-F self-report questionnaire score ranges from 0 to 10: a score ≥4 defines sarcopenia. The FNIH criteria uses handgrip strength (GS) and appendicular lean mass (ALM; assessed by DXA) divided by body mass index (BMI) to define sarcopenia. Outcome measures were the following performance-based tests: knee-extension strength, 6-m gait speed, and a repeated chair-stand test. The associations of sarcopenia with performance-based tests was examined using bootstrap multiple linear-regression models; adjusted R 2 determined the percentage variation for each outcome explained by the model. Prevalence of sarcopenia was 16.7% (n = 504) according to the SARC-F questionnaire and 1.8% (n = 49) using the FNIH criteria. Sensibility and specificity of the SARC-F to diagnose sarcopenia (defined by FNIH criteria) were 34% and 85%, respectively. Sarcopenic women defined by SARC-F had significantly lower physical performance than nonsarcopenic women. The SARC-F improved the ability to predict poor physical performance. The validity of the SARC-F questionnaire to screen for sarcopenia, when compared with the FNIH criteria, was limited. However, sarcopenia defined by the SARC-F questionnaire substantially improved the predictive value of clinical characteristics of patients to predict poor physical performance. Copyright © 2017 AMDA – The Society for Post-Acute and Long-Term Care Medicine. Published by Elsevier Inc. All rights reserved.

  3. Cost-effectiveness analysis of population-based screening of hepatocellular carcinoma: Comparing ultrasonography with two-stage screening

    PubMed Central

    Kuo, Ming-Jeng; Chen, Hsiu-Hsi; Chen, Chi-Ling; Fann, Jean Ching-Yuan; Chen, Sam Li-Sheng; Chiu, Sherry Yueh-Hsia; Lin, Yu-Min; Liao, Chao-Sheng; Chang, Hung-Chuen; Lin, Yueh-Shih; Yen, Amy Ming-Fang

    2016-01-01

    AIM: To assess the cost-effectiveness of two population-based hepatocellular carcinoma (HCC) screening programs, two-stage biomarker-ultrasound method and mass screening using abdominal ultrasonography (AUS). METHODS: In this study, we applied a Markov decision model with a societal perspective and a lifetime horizon for the general population-based cohorts in an area with high HCC incidence, such as Taiwan. The accuracy of biomarkers and ultrasonography was estimated from published meta-analyses. The costs of surveillance, diagnosis, and treatment were based on a combination of published literature, Medicare payments, and medical expenditure at the National Taiwan University Hospital. The main outcome measure was cost per life-year gained with a 3% annual discount rate. RESULTS: The results show that the mass screening using AUS was associated with an incremental cost-effectiveness ratio of USD39825 per life-year gained, whereas two-stage screening was associated with an incremental cost-effectiveness ratio of USD49733 per life-year gained, as compared with no screening. Screening programs with an initial screening age of 50 years old and biennial screening interval were the most cost-effective. These findings were sensitive to the costs of screening tools and the specificity of biomarker screening. CONCLUSION: Mass screening using AUS is more cost effective than two-stage biomarker-ultrasound screening. The most optimal strategy is an initial screening age at 50 years old with a 2-year inter-screening interval. PMID:27022228

  4. Parameter Optimization for Feature and Hit Generation in a General Unknown Screening Method-Proof of Concept Study Using a Design of Experiment Approach for a High Resolution Mass Spectrometry Procedure after Data Independent Acquisition.

    PubMed

    Elmiger, Marco P; Poetzsch, Michael; Steuer, Andrea E; Kraemer, Thomas

    2018-03-06

    High resolution mass spectrometry and modern data independent acquisition (DIA) methods enable the creation of general unknown screening (GUS) procedures. However, even when DIA is used, its potential is far from being exploited, because often, the untargeted acquisition is followed by a targeted search. Applying an actual GUS (including untargeted screening) produces an immense amount of data that must be dealt with. An optimization of the parameters regulating the feature detection and hit generation algorithms of the data processing software could significantly reduce the amount of unnecessary data and thereby the workload. Design of experiment (DoE) approaches allow a simultaneous optimization of multiple parameters. In a first step, parameters are evaluated (crucial or noncrucial). Second, crucial parameters are optimized. The aim in this study was to reduce the number of hits, without missing analytes. The obtained parameter settings from the optimization were compared to the standard settings by analyzing a test set of blood samples spiked with 22 relevant analytes as well as 62 authentic forensic cases. The optimization lead to a marked reduction of workload (12.3 to 1.1% and 3.8 to 1.1% hits for the test set and the authentic cases, respectively) while simultaneously increasing the identification rate (68.2 to 86.4% and 68.8 to 88.1%, respectively). This proof of concept study emphasizes the great potential of DoE approaches to master the data overload resulting from modern data independent acquisition methods used for general unknown screening procedures by optimizing software parameters.

  5. Multiloop atom interferometer measurements of chameleon dark energy in microgravity

    NASA Astrophysics Data System (ADS)

    Chiow, Sheng-wey; Yu, Nan

    2018-02-01

    Chameleon field is one of the promising candidates of dark energy scalar fields. As in all viable candidate field theories, a screening mechanism is implemented to be consistent with all existing tests of general relativity. The screening effect in the chameleon theory manifests its influence limited only to the thin outer layer of a bulk object, thus producing extra forces orders of magnitude weaker than that of the gravitational force of the bulk. For pointlike particles such as atoms, the depth of screening is larger than the size of the particle, such that the screening mechanism is ineffective and the chameleon force is fully expressed on the atomic test particles. Extra force measurements using atom interferometry are thus much more sensitive than bulk mass based measurements, and indeed have placed the most stringent constraints on the parameters characterizing chameleon field. In this paper, we present a conceptual measurement approach for chameleon force detection using atom interferometry in microgravity, in which multiloop atom interferometers exploit specially designed periodic modulation of chameleon fields. We show that major systematics of the dark energy force measurements, i.e., effects of gravitational forces and their gradients, can be suppressed below all hypothetical chameleon signals in the parameter space of interest.

  6. Gravitational lensing by a smoothly variable three-dimensional mass distribution

    NASA Technical Reports Server (NTRS)

    Lee, Man Hoi; Paczynski, Bohdan

    1990-01-01

    A smooth three-dimensional mass distribution is approximated by a model with multiple thin screens, with surface mass density varying smoothly on each screen. It is found that 16 screens are sufficient for a good approximation of the three-dimensional distribution of matter. It is also found that in this multiscreen model the distribution of amplifications of single images is dominated by the convergence due to matter within the beam. The shear caused by matter outside the beam has no significant effect. This finding considerably simplifies the modeling of lensing by a smooth three-dimensional mass distribution by effectively reducing the problem to one dimension, as it is sufficient to know the mass distribution along a straight light ray.

  7. Characterization of anti-theft devices directly from the surface of banknotes via easy ambient sonic spray ionization mass spectrometry.

    PubMed

    Schmidt, Eduardo Morgado; Franco, Marcos Fernando; Cuelbas, Claudio José; Zacca, Jorge Jardim; de Carvalho Rocha, Werickson Fortunato; Borges, Rodrigo; de Souza, Wanderley; Sawaya, Alexandra Christine Helena Frankland; Eberlin, Marcos Nogueira; Correa, Deleon Nascimento

    2015-09-01

    Using Brazilian banknotes as a test case, forensic examination and identification of Rhodamine B dye anti-theft device (ATD) staining on banknotes were performed. Easy ambient sonic spray ionization mass spectrometry (EASI-MS) was used since it allows fast and simple analysis with no sample preparation providing molecular screening of the surface with direct desorption and ionization of the security dye. For a more accurate molecular characterization of the ATD dye, Q Exactive Orbitrap™ Fourier transform (tandem) mass spectrometry using eletrospray ionization (ESI-HRMS/MS) was also applied. Copyright © 2015 The Chartered Society of Forensic Sciences. Published by Elsevier Ireland Ltd. All rights reserved.

  8. Buprenorphine detection in hair samples by immunometric screening test: preliminary experience.

    PubMed

    Svaizer, Fiorenza; Lotti, Andrea; Gottardi, Massimo; Miozzo, Maria Pia

    2010-03-20

    The recent introduction of buprenorphine use by the Drug Addiction Services has induced toxicology laboratories to develop new qualitative or semiquantitative screening assay for its determination in hair samples. The aim of this preliminary study was to verify the correlation between the buprenorphine intake and the immunometric screening test results (VMA-T Comedical and buprenorphine CEDIA/Thermo-Fisher/Microgenics reagents) and therefore their comparison with the liquid chromatography coupled with mass spectrometry (LC/MS) results. Hair samples were obtained from 32 subjects without buprenorphine-therapy reported and 17 in treatment. In glass test tube with hermetic cap were weighed 33 mg of 49 finely cut hair samples, washed with 1 mL of SLV-VMA-T washing solution, which is then completely sucked and eliminated. The samples were extracted with 400 microL of VMA-T reagent for an hour at 100 degrees C. The extracts were analysed by immunometric screening test on ILab 650 chemistry analyser, using buprenorphine CEDIA reagent assay. From the 32 non-takers of drug, 30 semiquantitative results were less than 10 pg/mg and 2 were over 10 pg/mg; from the 17 subjects with therapy, all were over 10 pg/mg (range 13-50 pg/mg); no samples were false-negative. Results suggest that exist a good relationship between the administration of buprenorphine and its concentration in hair, detectable through this method and reagents line. Copyright 2010 Elsevier Ireland Ltd. All rights reserved.

  9. Gauge-invariant screening masses and static quark free energies in Nf=2 +1 QCD at nonzero baryon density

    NASA Astrophysics Data System (ADS)

    Andreoli, Michele; Bonati, Claudio; D'Elia, Massimo; Mesiti, Michele; Negro, Francesco; Rucci, Andrea; Sanfilippo, Francesco

    2018-03-01

    We discuss the extension of gauge-invariant electric and magnetic screening masses in the quark-gluon plasma to the case of a finite baryon density, defining them in terms of a matrix of Polyakov loop correlators. We present lattice results for Nf=2 +1 QCD with physical quark masses, obtained using the imaginary chemical potential approach, which indicate that the screening masses increase as a function of μB. A separate analysis is carried out for the theoretically interesting case μB/T =3 i π , where charge conjugation is not explicitly broken and the usual definition of the screening masses can be used for temperatures below the Roberge-Weiss transition. Finally, we investigate the dependence of the static quark free energy on the baryon chemical potential, showing that it is a decreasing function of μB, which displays a peculiar behavior as the pseudocritical transition temperature at μB=0 is approached.

  10. Drug screening in medical examiner casework by high-resolution mass spectrometry (UPLC-MSE-TOF).

    PubMed

    Rosano, Thomas G; Wood, Michelle; Ihenetu, Kenneth; Swift, Thomas A

    2013-10-01

    Postmortem drug findings yield important analytical evidence in medical examiner casework, and chromatography coupled with nominal mass spectrometry (MS) serves as the predominant general unknown screening approach. We report screening by ultra performance liquid chromatography (UPLC) coupled with hybrid quadrupole time-of-flight mass spectrometer (MS(E)-TOF), with comparison to previously validated nominal mass UPLC-MS and UPLC-MS-MS methods. UPLC-MS(E)-TOF screening for over 950 toxicologically relevant drugs and metabolites was performed in a full-spectrum (m/z 50-1,000) mode using an MS(E) acquisition of both molecular and fragment ion data at low (6 eV) and ramped (10-40 eV) collision energies. Mass error averaged 1.27 ppm for a large panel of reference drugs and metabolites. The limit of detection by UPLC-MS(E)-TOF ranges from 0.5 to 100 ng/mL and compares closely with UPLC-MS-MS. The influence of column recovery and matrix effect on the limit of detection was demonstrated with ion suppression by matrix components correlating closely with early and late eluting reference analytes. Drug and metabolite findings by UPLC-MS(E)-TOF were compared with UPLC-MS and UPLC-MS-MS analyses of postmortem blood in 300 medical examiner cases. Positive findings by all methods totaled 1,528, with a detection rate of 57% by UPLC-MS, 72% by UPLC-MS-MS and 80% by combined UPLC-MS and UPLC-MS-MS screening. Compared with nominal mass screening methods, UPLC-MS(E)-TOF screening resulted in a 99% detection rate and, in addition, offered the potential for the detection of nontargeted analytes via high-resolution acquisition of molecular and fragment ion data.

  11. Optimizing urine drug testing for monitoring medication compliance in pain management.

    PubMed

    Melanson, Stacy E F; Ptolemy, Adam S; Wasan, Ajay D

    2013-12-01

    It can be challenging to successfully monitor medication compliance in pain management. Clinicians and laboratorians need to collaborate to optimize patient care and maximize operational efficiency. The test menu, assay cutoffs, and testing algorithms utilized in the urine drug testing panels should be periodically reviewed and tailored to the patient population to effectively assess compliance and avoid unnecessary testing and cost to the patient. Pain management and pathology collaborated on an important quality improvement initiative to optimize urine drug testing for monitoring medication compliance in pain management. We retrospectively reviewed 18 months of data from our pain management center. We gathered data on test volumes, positivity rates, and the frequency of false positive results. We also reviewed the clinical utility of our testing algorithms, assay cutoffs, and adulterant panel. In addition, the cost of each component was calculated. The positivity rate for ethanol and 3,4-methylenedioxymethamphetamine were <1% so we eliminated this testing from our panel. We also lowered the screening cutoff for cocaine to meet the clinical needs of the pain management center. In addition, we changed our testing algorithm for 6-acetylmorphine, benzodiazepines, and methadone. For example, due the high rate of false negative results using our immunoassay-based benzodiazepine screen, we removed the screening portion of the algorithm and now perform benzodiazepine confirmation up front in all specimens by liquid chromatography-tandem mass spectrometry. Conducting an interdisciplinary quality improvement project allowed us to optimize our testing panel for monitoring medication compliance in pain management and reduce cost. Wiley Periodicals, Inc.

  12. Antiretroviral drug use and HIV drug resistance among MSM and transgender women in sub-Saharan Africa.

    PubMed

    Zhang, Yinfeng; Fogel, Jessica M; Guo, Xu; Clarke, William; Breaud, Autumn; Cummings, Vanessa; Hamilton, Erica L; Ogendo, Arthur; Kayange, Noel; Panchia, Ravindre; Dominguez, Karen; Chen, Ying Q; Sandfort, Theodorus; Eshleman, Susan H

    2018-06-19

    To analyze antiretroviral drug use and HIV drug resistance among HIV-infected MSM and transgender women who were screened for participation in the HIV Prevention Trials Network 075 study. A qualitative assay was used to detect 20 antiretroviral drugs in five drug classes; this assay is based on liquid chromatography coupled with high-resolution accurate-mass mass spectrometry. HIV viral load testing was performed using the RealTime HIV-1 Viral Load Assay. HIV drug resistance testing was performed using the ViroSeq HIV-1 Genotyping System. Logistic regression was used to evaluate factors associated with study outcomes. Antiretroviral drugs were detected in 63 (34.4%) of 183 participants who had confirmed HIV infection at screening; 11 (17.5%) of the 63 participants were not virally suppressed. Six (54.5%) of the 11 participants had drug-resistant HIV, including four who had multiclass resistance. Seven (63.6%) of the 11 were at risk of acquiring resistance to additional antiretroviral drugs. In multivariate model, antiretroviral drugs were more frequently detected in older participants, those recruited from Kisumu, Kenya, and those who reported ever having been in HIV care or on antiretroviral therapy (ART). Most of HIV-infected persons screened for participation in HIV Prevention Trials Network 075 were not on ART, and many of those who were on ART were not virally suppressed. Many of those participants had drug-resistant HIV. These findings highlight the need for improved HIV care for African MSM and transgender women.

  13. The feasibility of a fluidic respiratory flow meter

    NASA Technical Reports Server (NTRS)

    Neradka, V. F.; Bray, H. C., Jr.

    1974-01-01

    A study was undertaken to determine the feasibility of adapting a fluidic airspeed sensor for use as a respiratory flowmeter. A Pulmonary Function Testing Flowmeter was developed which should prove useful for mass screening applications. The fluidic sensor threshold level was not reduced sufficiently to permit its adaptation to measuring the low respiratory flow rates encountered in many respiratory disorders.

  14. Dietary flavonols contribute to false-positive elevation of homovanillic acid, a marker of catecholamine-secreting tumors.

    PubMed

    Combet, Emilie; Lean, Michael E J; Boyle, James G; Crozier, Alan; Davidson, D Fraser

    2011-01-14

    Urinary homovanillic acid (HVA) measurement is used routinely as a marker of the first test for the screening of catecholamine-secreting tumors and dopamine metabolism, but generates a large number of false-positive results. With no guidelines for dietary restrictions prior to the test, we hypothesize that consumption of flavonol-rich foods (such as onions, tomatoes, tea) prior to urinary catecholamine screening could be responsible for false-positive urinary HVA in healthy subjects. A randomized, crossover dietary intervention was carried out in healthy subjects (n=17). Volunteers followed either a low or high-flavonol diet, for a duration of 3 days, prior to providing a 24-h urine sample for HVA measurement using a routine, validated liquid chromatography method as well as a gas chromatography-mass spectrometry method. Dietary flavonol intake significantly increased urinary HVA excretion (p < 0.001), with 3 out of 17 volunteers (20%) exceeding the 40 μmol/24 h upper limit of normal for HVA excretion (false-positive result). Dietary flavonols commonly found in foodstuff such as tomatoes, onions, and tea, interfered with the routine urinary HVA screening test and should be avoided in the three-day run-up to the test. Copyright © 2010 Elsevier B.V. All rights reserved.

  15. Ethical issues in genetic counselling with special reference to haemoglobinopathies.

    PubMed

    Muthuswamy, Vasantha

    2011-10-01

    Genetic counselling is provided in places where genetic tests are carried out. The process involves pre-test counselling as well as post-test counselling to enable the individuals to face the situation and take appropriate decisions with the right frame of mind. Major ethical principles which govern the attitudes and actions of counsellors include: respect for patient autonomy, non-maleficence, beneficence, or taking action to help benefit others and prevent harm, both physical and mental, and justice, which requires that services be distributed fairly to those in need. Other moral issues include veracity, the duty to disclose information or to be truthful, and respect for patient confidentiality. Nondirective counselling, a hallmark of this profession, is in accordance with the principle of individual autonomy. High prevalence of haemoglobinopathies with availability of good and sensitive carrier detection tests and prenatal diagnostic techniques makes these good candidates for population screening of carriers along with genetic counselling for primary prevention of the disease. Screening of the extended family members of the affected child, high risk communities and general population screening including antenatal women are the main target groups for planning a Haemoglobinopathy control programme. A critical mass of trained genetic counsellors who have understanding of the ethical issues and its appropriate handling with the required sensitivity is needed in India.

  16. Synthesis, in vitro anticancer and antimycobacterial evaluation of new 5-(2,5-dimethoxyphenyl)-1,3,4-thiadiazole-2-amino derivatives.

    PubMed

    Polkam, Naveen; Rayam, Parsharamulu; Anireddy, Jaya Shree; Yennam, Satyanarayana; Anantaraju, Hasitha Shilpa; Dharmarajan, Sriram; Perumal, Yogeeswari; Kotapalli, Sudha Sravanti; Ummanni, Ramesh; Balasubramanian, Sridhar

    2015-04-01

    A series of 2,5-disubstituted-1,3,4-thiadiazole derivatives 5a-5l, 7a-7e and 9 have been synthesised and screened for in vitro antimycobacterial activity against Mycobacterium smegmatis MC-155. In addition these compounds have also been screened for cytotoxic activity against cancer cell lines HT-29, MDA-MB-231 by MTT colorimetric assay. The compounds are well characterized by spectral analysis viz. (1)H NMR, (13)C NMR, FT-IR, mass and HRMS. Screening results indicate that compounds 5g, 7a possess good antitubercular activity with MIC value 65.74 and 40.86, respectively, compounds 5g, 7a, 7b, 7d, 7e and 9 displayed promising cytotoxic activity against the cell lines tested. 5g and 7a stand out to be potent antimycobacterial and anticancer agents among the tested series. Further the title compounds were also tested on human normal cells HEK293T and are found to be safer with lesser cytotoxicity. It is interesting to observe that compound 5g has come out to be safer, potent anticancer and antimycobacterial agent. Copyright © 2015 Elsevier Ltd. All rights reserved.

  17. Outcome and cost of a statewide diabetes screening and awareness initiative in New York.

    PubMed

    Hosler, Akiko S; Berberian, Elizabeth L; Spence, Maureen M; Hoffman, David P

    2005-01-01

    From 1997 through 1999, a total of 365 diabetes screening and awareness events targeting high-risk populations were held throughout New York State. These events were planned and implemented by community-based coalitions that received funding from the state's Diabetes Control Program. The American Diabetes Association's diabetes risk questionnaire was administered, and those individuals identified as high risk received a capillary blood glucose test. Screened individuals with glucose readings above the cut-off value (140 mg/dl or 110 mg/dl if fasting) were referred to a physician for diagnostic testing. A total of 32,954 individuals took the questionnaire, 27,237 received the blood test, and 1,564 were referred to a physician. Among those who were successfully tracked (n = 1,113), 354 were newly diagnosed with diabetes mellitus. Seventy-two percent of participants screened were aged 45 years and older, and 67% had a body mass index of 25 or higher. Only 15% were members of ethnic minorities, and uninsured individuals were also underrepresented at 10%. The entire initiative, including planning, promotion, and administration, required 5,428 person-hours of staff time and a total cost of approximately 262,000 dollars. Fifty-seven percent of the total cost was derived from in-kind support of the coalitions. The cost of detecting each new case was 741 dollars.

  18. Identification of prenatal amphetamines exposure by maternal interview and meconium toxicology in the Infant Development, Environment and Lifestyle (IDEAL) study.

    PubMed

    Gray, Teresa R; LaGasse, Linda L; Smith, Lynne M; Derauf, Chris; Grant, Penny; Shah, Rizwan; Arria, Amelia M; Della Grotta, Sheri A; Strauss, Arthur; Haning, William F; Lester, Barry M; Huestis, Marilyn A

    2009-12-01

    The Infant Development Environment and Lifestyle study is investigating the effects of prenatal methamphetamine (MAMP) exposure on infant and child development; potential concurrent exposure to cannabis and tobacco also are evaluated. Maternal self-reported drug use and/or meconium toxicology results defined drug exposure status. It is unclear how the frequency, duration, and magnitude of maternal MAMP exposure affect qualitative and quantitative meconium results. Interviews regarding maternal drug use were collected shortly after birth; meconium specimens were screened for amphetamines, cannabis, and cotinine by immunoassay and confirmed by gas chromatography mass spectrometry. The majority of MAMP- and cannabis-exposed infants were identified by maternal interview alone. Meconium tests were more likely to be positive if the mother reported MAMP and cannabis use, particularly in the third trimester. Less than half of immunoassay-positive amphetamines (31.0%) and cannabis (17.9%) meconium results were confirmed by gas chromatography mass spectrometry. Tobacco exposure was equally detected by immunoassay cotinine screening and maternal report. Meconium concentrations did not correlate with maternal self-report status or trimester of use or frequency or route of MAMP use. Maternal self-report was more sensitive than meconium testing for identifying MAMP and cannabis-exposed neonates; however, the timing of drug exposure may influence meconium toxicology results. Most women stopped MAMP and cannabis use before the third trimester. In the first trimester, meconium has not yet formed, and based on our recent results for opiates and cocaine, drug use in the second trimester appears to be poorly reflected in meconium. Low confirmation rates in meconium reinforce the need for confirmatory testing following positive screening results and additional research to identify alternative biomarkers.

  19. Epidemiologic Evidence That Excess Body Weight Increases Risk of Cervical Cancer by Decreased Detection of Precancer.

    PubMed

    Clarke, Megan A; Fetterman, Barbara; Cheung, Li C; Wentzensen, Nicolas; Gage, Julia C; Katki, Hormuzd A; Befano, Brian; Demarco, Maria; Schussler, John; Kinney, Walter K; Raine-Bennett, Tina R; Lorey, Thomas S; Poitras, Nancy E; Castle, Philip E; Schiffman, Mark

    2018-04-20

    Purpose Obesity has been inconsistently linked to increased cervical cancer incidence and mortality; however, the effect of obesity on cervical screening has not been explored. We investigated the hypothesis that increased body mass might decrease detection of cervical precancer and increase risk of cervical cancer even in women undergoing state-of-the-art screening. Methods We conducted a retrospective cohort study of 944,227 women age 30 to 64 years who underwent cytology and human papillomavirus DNA testing (ie, cotesting) at Kaiser Permanente Northern California (January 2003 to December 2015). Body mass index was categorized as normal/underweight (< 25 kg/m 2 ), overweight (25 to < 30 kg/m 2 ), or obese (≥ 30 kg/m 2 ). We estimated 5-year cumulative risks of cervical precancer and cancer by category of body mass index using logistic Weibull survival models. Results We observed lower risk of cervical precancer (n = 4,489) and higher risk of cervical cancer (n = 490) with increasing body mass index. Specifically, obese women had the lowest 5-year risk of precancer (0.51%; 95% CI, 0.48% to 0.54% v 0.73%; 95% CI, 0.70% to 0.76% in normal/underweight women; P trend < .001). In contrast, obese women had the highest 5-year risk of cancer (0.083%; 95% CI, 0.072% to 0.096% v 0.056%; 95% CI, 0.048% to 0.066% in normal/underweight women; P trend < .001). Results were consistent in subgroups defined by age (30 to 49 v 50 to 64 years), human papillomavirus status (positive v negative), and histologic subtype (glandular v squamous). Approximately 20% of cervical cancers could be attributed to overweight or obesity in the women in our study who underwent routine cervical screening. Conclusion In this large, screened population, overweight and obese women had an increased risk of cervical cancer, likely because of underdiagnosis of cervical precancer. Improvements in equipment and/or technique to assure adequate sampling and visualization of women with elevated body mass might reduce cervical cancer incidence.

  20. [Screening and confirmation of 24 hormones in cosmetics by ultra high performance liquid chromatography-linear ion trap/orbitrap high resolution mass spectrometry].

    PubMed

    Li, Zhaoyong; Wang, Fengmei; Niu, Zengyuan; Luo, Xin; Zhang, Gang; Chen, Junhui

    2014-05-01

    A method of ultra high performance liquid chromatography-linear ion trap/orbitrap high resolution mass spectrometry (UPLC-LTQ/Orbitrap MS) was established to screen and confirm 24 hormones in cosmetics. Various cosmetic samples were extracted with methanol. The extract was loaded onto a Waters ACQUITY UPLC BEH C18 column (50 mm x 2.1 mm, 1.7 microm) using a gradient elution of acetonitrile/water containing 0.1% (v/v) formic acid for the separation. The accurate mass of quasi-molecular ion was acquired by full scanning of electrostatic field orbitrap. The rapid screening was carried out by the accurate mass of quasi-molecular ion. The confirmation analysis for targeted compounds was performed with the retention time and qualitative fragments obtained by data dependent scan mode. Under the optimal conditions, the 24 hormones were routinely detected with mass accuracy error below 3 x 10(-6) (3 ppm), and good linearities were obtained in their respective linear ranges with correlation coefficients higher than 0.99. The LODs (S/N = 3) of the 24 compounds were < or = 10 microg/kg, which can meet the requirements for the actual screening of cosmetic samples. The developed method was applied to screen the hormones in 50 cosmetic samples. The results demonstrate that the method is a useful tool for the rapid screening and identification of the hormones in cosmetics.

  1. Solid versus Liquid Particle Sampling Efficiency of Three Personal Aerosol Samplers when Facing the Wind

    PubMed Central

    Koehler, Kirsten A.; Anthony, T. Renee; Van Dyke, Michael

    2016-01-01

    The objective of this study was to examine the facing-the-wind sampling efficiency of three personal aerosol samplers as a function of particle phase (solid versus liquid). Samplers examined were the IOM, Button, and a prototype personal high-flow inhalable sampler head (PHISH). The prototype PHISH was designed to interface with the 37-mm closed-face cassette and provide an inhalable sample at 10 l min−1 of flow. Increased flow rate increases the amount of mass collected during a typical work shift and helps to ensure that limits of detection are met, particularly for well-controlled but highly toxic species. Two PHISH prototypes were tested: one with a screened inlet and one with a single-pore open-face inlet. Personal aerosol samplers were tested on a bluff-body disc that was rotated along the facing-the-wind axis to reduce spatiotemporal variability associated with sampling supermicron aerosol in low-velocity wind tunnels. When compared to published data for facing-wind aspiration efficiency for a mouth-breathing mannequin, the IOM oversampled relative to mannequin facing-the-wind aspiration efficiency for all sizes and particle types (solid and liquid). The sampling efficiency of the Button sampler was closer to the mannequin facing-the-wind aspiration efficiency than the IOM for solid particles, but the screened inlet removed most liquid particles, resulting in a large underestimation compared to the mannequin facing-the-wind aspiration efficiency. The open-face PHISH results showed overestimation for solid particles and underestimation for liquid particles when compared to the mannequin facing-the-wind aspiration efficiency. Substantial (and statistically significant) differences in sampling efficiency were observed between liquid and solid particles, particularly for the Button and screened-PHISH, with a majority of aerosol mass depositing on the screened inlets of these samplers. Our results suggest that large droplets have low penetration efficiencies through screened inlets and that particle bounce, for solid particles, is an important determinant of aspiration and sampling efficiencies for samplers with screened inlets. PMID:21965462

  2. True ion pick (TIPick): a denoising and peak picking algorithm to extract ion signals from liquid chromatography/mass spectrometry data.

    PubMed

    Ho, Tsung-Jung; Kuo, Ching-Hua; Wang, San-Yuan; Chen, Guan-Yuan; Tseng, Yufeng J

    2013-02-01

    Liquid Chromatography-Time of Flight Mass Spectrometry has become an important technique for toxicological screening and metabolomics. We describe TIPick a novel algorithm that accurately and sensitively detects target compounds in biological samples. TIPick comprises two main steps: background subtraction and peak picking. By subtracting a blank chromatogram, TIPick eliminates chemical signals of blank injections and reduces false positive results. TIPick detects peaks by calculating the S(CC(INI)) values of extracted ion chromatograms (EICs) without considering peak shapes, and it is able to detect tailing and fronting peaks. TIPick also uses duplicate injections to enhance the signals of the peaks and thus improve the peak detection power. Commonly seen split peaks caused by either saturation of the mass spectrometer detector or a mathematical background subtraction algorithm can be resolved by adjusting the mass error tolerance of the EICs and by comparing the EICs before and after background subtraction. The performance of TIPick was tested in a data set containing 297 standard mixtures; the recall, precision and F-score were 0.99, 0.97 and 0.98, respectively. TIPick was successfully used to construct and analyze the NTU MetaCore metabolomics chemical standards library, and it was applied for toxicological screening and metabolomics studies. Copyright © 2013 John Wiley & Sons, Ltd.

  3. Technical aspects of neonatal screening using tandem mass spectrometry. Report from the 4th meeting of the International Society for Neonatal Screening.

    PubMed

    Simonsen, H; Jensen, U G

    1999-12-01

    Quantitative analysis of amino acids (AA) and acylcarnitines using tandem mass spectrometry is an emerging technology used to screen neonatal dried blood spot samples for disorders in the metabolism of AA, organic acids and fatty acids. This paper provides a brief review of some of the technically oriented issues which emerged at the 4th meeting of the International Society for Neonatal Screening in Stockholm, 1999. The information covers sample preparation, instrumentation, data acquistion modes, internal standards, interpretation, confounding factors and practical screening experience.

  4. What the neurosurgeon should know about hemangioblastoma, both sporadic and in Von Hippel-Lindau disease: A literature review

    PubMed Central

    Bamps, Sven; Calenbergh, Frank Van; Vleeschouwer, Steven De; Loon, Johannes Van; Sciot, Raf; Legius, Eric; Goffin, Jan

    2013-01-01

    Background: Hemangioblastomas are associated with Von Hippel-Lindau disease (VHLD) in 10-40% of cases. Based upon a literature review we state the core features the neurosurgeon should be aware of. Methods: We performed a selective literature (Cochrane and Medline) search for hemangioblastoma, both sporadic and VHL associated. We reviewed general characteristics (epidemiology, symptomatology, diagnosis, and management) and focused on follow-up as well as screening modalities for sporadic and VHL associated lesions. Results: Based upon our literature search, we established guidelines for screening and follow-up in both sporadic and VHL associated hemangioblastoma patients. Conclusions: Screening for retinal angiomas, abdominal masses, and pheochromocytomas as well as genetic analysis is recommended for every patient with a newly diagnosed hemangioblastoma. Follow-up is by magnetic resonance imaging (MRI) of the clinical neuronal region at 6 and at 12-24 months postoperatively. For VHL-associated hemangioblastomas yearly investigation for craniospinal hemangioblastoma by MRI and yearly screening and follow-up for retinal angiomas is recommended. Annual abdominal ultrasound with triennial computed tomography (CT) imaging for abdominal masses is postulated. Annual audiometry is to be performed for possible endolymphatic sac tumor, detailed radiographic imaging of the skull base should be performed upon abnormality in auditory testing. Investigations for cystadenomas of the epidydimis and broad ligament only are mandatory on indication. Annual investigation for pheochromocytoma is recommended. PMID:24340227

  5. A SIMPLE AND RAPID MATRIX-ASSISTED LASER DESORPTION/IONIZATION TIME OF FLIGHT MASS SPECTROMETRY METHOD TO SCREEN FISH PLASMA SAMPLES FOR ESTROGEN-RESPONSIVE BIOMARKERS

    EPA Science Inventory

    In this study, we describe and evaluate the performance of a simple and rapid mass spectral method for screening fish plasma for estrogen-responsive biomarkers using matrix assisted laster desorption/ionization time of flight mass spectrometry (MALDI-TOF-MS) couopled with a short...

  6. Mass Screening for Celiac Disease Among School-aged Children: Toward Exploring Celiac Iceberg in Saudi Arabia.

    PubMed

    Al-Hussaini, Abdulrahman; Troncone, Riccardo; Khormi, Musa; AlTuraiki, Muath; Alkhamis, Wahid; Alrajhi, Mona; Halal, Thana; Fagih, Mosa; Alharbi, Sahar; Bashir, Muhammed Salman; Chentoufi, Aziz Alami

    2017-12-01

    We conducted this mass screening study to determine the prevalence of celiac disease (CD) and characterize the celiac iceberg among Saudi pediatric population in Riyadh, the capital city of Saudi Arabia. During the study period (January 2014-June 2016), we have conducted a cross-sectional, mass screening, immunoglobulin A-tissue transglutaminase (TTG-IgA)-based study on 7930 Saudi students from primary and intermediate schools in Riyadh. Students with positive TTG-IgA (>20 U/L) were called in the hospital to undergo a repeat of TTG-IgA; in those with borderline positive TTG-IgA (20-60 U/L), IgA-endomyseal antibody (EMA-IgA) test was performed. Children with TTG-IgA >60 U/L and children with borderline positive TTG-IgA and positive EMA-IgA were advised to undergo upper endoscopy and intestinal biopsies. We identified 221 students with positive TTG-IgA (2.8%). CD was diagnosed in 119 cases (1.5%, 1:67 Saudi children) (mean age 11.5 ± 2.62 years; girls 81 [68%]). Another 51 children had persistently borderline positive TTG-IgA but negative EMA (0.64%) and the remaining 51 had transiently positive TTG-IgA. We have identified 3 clinical patterns in the screening-identified cases with CD: a silent form (37%), a mild symptomatic form characterized by gastrointestinal symptoms in presence of normal growth or overweight/obesity (48%), and gastrointestinal symptoms associated with impaired growth in 15%. Our study provided evidence of a high prevalence of CD among Saudi children (1.5%), a rate that is at least twice the average prevalence rate in Europe and North America.

  7. Screening of carnitine and biotin deficiencies on tandem mass spectrometry.

    PubMed

    Hagiwara, Shin-Ichiro; Kubota, Mitsuru; Nambu, Ryusuke; Kagimoto, Seiichi

    2017-04-01

    It is important to assess pediatric patients for nutritional deficiency when they are receiving specific interventions, such as enteral feeding. We focused on measurement of C0 and 3-hydroxyisovalerylcarnitine (C5-OH) with tandem mass spectrometry (MS/MS), which is performed as part of the newborn mass screening. The purpose of this study was to investigate the usefulness of MS/MS for screening carnitine and biotin deficiencies. Forty-two children (24 boys, 18 girls) were enrolled between December 2013 and December 2015. Blood tests, including measurement of serum free carnitine via the enzyme cycling method, and acylcarnitine analysis on MS/MS of dried blood spot (DBS), were performed for the evaluation of nutrition status. Median patient age was 2 years (range, 2 months-14 years). Mean serum free carnitine was 41.8 ± 19.2 μmol/L. In six of the 42 patients, serum free carnitine was <20 μmol/L (range, 4.0-18.7 μmol/L). C0 and C5-OH measured on MS/MS of DBS were 33.8 ± 20.2 nmol/mL and 0.48 ± 0.22 nmol/mL, respectively. There was a strong positive correlation (r = 0.89, P < 0.001) between serum free carnitine and C0 measured on the same day. In one patient on hydrolyzed formula, C5-OH was >1.00 nmol/L. Therapy-resistant eczema was improved by treatment with additional biotin and a non-hydrolyzed formula. C0 and C5-OH, measured on MS/MS of DBS, were useful for screening carnitine and biotin deficiencies. © 2016 Japan Pediatric Society.

  8. What implementation interventions increase cancer screening rates? a systematic review

    PubMed Central

    2011-01-01

    Background Appropriate screening may reduce the mortality and morbidity of colorectal, breast, and cervical cancers. However, effective implementation strategies are warranted if the full benefits of screening are to be realized. As part of a larger agenda to create an implementation guideline, we conducted a systematic review to evaluate interventions designed to increase the rate of breast, cervical, and colorectal cancer (CRC) screening. The interventions considered were: client reminders, client incentives, mass media, small media, group education, one-on-one education, reduction in structural barriers, reduction in out-of-pocket costs, provider assessment and feedback interventions, and provider incentives. Our primary outcome, screening completion, was calculated as the overall median post-intervention absolute percentage point (PP) change in completed screening tests. Methods Our first step was to conduct an iterative scoping review in the research area. This yielded three relevant high-quality systematic reviews. Serving as our evidentiary foundation, we conducted a formal update. Randomized controlled trials and cluster randomized controlled trials, published between 2004 and 2010, were searched in MEDLINE, EMBASE and PSYCHinfo. Results The update yielded 66 studies new eligible studies with 74 comparisons. The new studies ranged considerably in quality. Client reminders, small media, and provider audit and feedback appear to be effective interventions to increase the uptake of screening for three cancers. One-on-one education and reduction of structural barriers also appears effective, but their roles with CRC and cervical screening, respectively, are less established. More study is required to assess client incentives, mass media, group education, reduction of out-of-pocket costs, and provider incentive interventions. Conclusion The new evidence generally aligns with the evidence and conclusions from the original systematic reviews. This review served as the evidentiary foundation for an implementation guideline. Poor reporting, lack of precision and consistency in defining operational elements, and insufficient consideration of context and differences among populations are areas for additional research. PMID:21958556

  9. Large Subpectoral Lipoma on Screening Mammography

    PubMed Central

    Su, Andres; Margolies, Laurie

    2017-01-01

    A 61 year-old woman presenting for bilateral screening mammogram was found to have an oval fat-density mass in the posterior right breast, partially visualized, with anterior displacement and thinning of the pectoralis major muscle. This mass was found on CT and MRI correlation to represent a large fat-containing mass, likely a lipoma, deep to the pectoralis major. On subsequent screening mammograms, the visualized portion of the mass remained stable. Subpectoral lipomas and intramuscular lipomas within the pectoralis major are rare, and their appearance on mammography may not be familiar to most radiologists. A review of the literature and a discussion of their appearance on multiple imaging modalities is provided. PMID:29299106

  10. Identification and ultra-high-performance liquid chromatography coupled with high-resolution mass spectrometry characterization of biosurfactants, including a new surfactin, isolated from oil-contaminated environments.

    PubMed

    Moro, Glaci V; Almeida, Rafaela T R; Napp, Amanda P; Porto, Carla; Pilau, Eduardo J; Lüdtke, Diogo S; Moro, Angélica V; Vainstein, Marilene H

    2018-05-14

    Biosurfactant-producing bacteria were isolated from samples collected in areas contaminated with crude oil. The isolates were screened for biosurfactant production using qualitative drop-collapse test, oil-spreading and emulsification assays, and measurement of their tensoactive properties. Five isolates tested positive for in the screening experiments and displayed decrease in the surface tension below 30 mN m -1 . The biosurfactants produced by these isolates were further investigated and their molecular identification revealed that they are bacteria related to the Bacillus genus. Additionally, the biosurfactants produced were chemically characterized via UHPLC-HRMS experiments, indicating the production of surfactin homologues, including a new class of these molecules. © 2018 The Authors. Microbial Biotechnology published by John Wiley & Sons Ltd and Society for Applied Microbiology.

  11. Derivation of gender and age-specific reference intervals from fully normal Japanese individuals and the implications for health screening.

    PubMed

    Yamakado, Minoru; Ichihara, Kiyoshi; Matsumoto, Yoshiyuki; Ishikawa, Yoshiki; Kato, Kiminori; Komatsubara, Yusuke; Takaya, Norihide; Tomita, Shohken; Kawano, Reo; Takada, Keisuke; Watanabe, Kiyoaki

    2015-07-20

    With nationwide standardization of laboratory tests among institutions for health screening in Japan, common reference intervals (RIs) were derived from records of 1,500,000 health check attendees. Targets were 20 basic laboratory tests including body mass index (BMI) and systolic and diastolic blood pressures (SBP, DBP). Individuals fulfilling the following strict criteria were chosen: SBP<130, DBP<85mmHg, BMI<25kg/m(2), non-smoking, ethanol consumption<20g/day and under no mediation with no remarkable current/past illnesses. The latent abnormal values exclusion (LAVE) method was applied to ensure fully normal results. RIs were derived by parametric method using modified Box-Cox power transformation. Among all attendees, 23% fulfilled the criteria. Application of the LAVE method further reduced the dataset by 40%-50%. Age-related charts of test results differed greatly between genders in almost all tests. Comparison of derived RIs with clinical decision limits (CDLs) revealed that the upper limits of RIs differed from CDLs according to gender and age. Implementation of gender and age-specific RIs derived from individuals with fully normal health attributes will (1) enable appropriate interpretation of test results in health screening and (2) promote judicious application of CDLs for therapeutic intervention, taking into account gender, age and other health attributes. Copyright © 2015 Elsevier B.V. All rights reserved.

  12. A new mass screening method for methylmercury poisoning using mercury-volatilizing bacteria from Minamata Bay.

    PubMed

    Nakamura, K; Naruse, I; Takizawa, Y

    1999-09-01

    A simplified mass screening method for methylmercury exposure was developed using methylmercury-volatilizing bacteria from Minamata Bay. Some bacteria can transform methylmercury into mercury vapor. Most mercury in the hair is methylmercury, which is readily extracted with HCl solution. Black spots are formed on X-ray film due to the reduction of Ag(+) emulsion with mercury vapor produced by methylmercury-volatilizing bacteria. By exploiting these characteristics, a screening method was developed, whereby the fur of rats injected with methylmercury chloride formed clear black spots on X-ray film, whereas the fur of rats injected with saline did not. Subsequently, 50 human hair samples were examined using this mass screening method. The method identified people who had high mercury concentration, over 20 microg/g. A few thousand hair samples may be screened in a day using this method because it is rapid, simple, and economical. This method, therefore, enables screening of persons with methylmercury poisoning in mercury-polluted areas. Copyright 1999 Academic Press.

  13. A systematic study of mass spectra and strong decay of strange mesons

    NASA Astrophysics Data System (ADS)

    Pang, Cheng-Qun; Wang, Jun-Zhang; Liu, Xiang; Matsuki, Takayuki

    2017-12-01

    The mass spectrum of the kaon family is analyzed by the modified Godfrey-Isgur model with a color screening effect approximating the kaon as a heavy-light meson system. This analysis gives us the structure and possible assignments of the observed kaon candidates, which can be tested by comparing the theoretical results of their two-body strong decays with the experimental data. Additionally, prediction of some partial decay widths is made on the kaons still missing in experiment. This study is crucial to establishing the kaon family and searching for their higher excitations in the future.

  14. Endoscopy in screening for digestive cancer

    PubMed Central

    Lambert, René

    2012-01-01

    The aim of this study is to describe the role of endoscopy in detection and treatment of neoplastic lesions of the digestive mucosa in asymptomatic persons. Esophageal squamous cell cancer occurs in relation to nutritional deficiency and alcohol or tobacco consumption. Esophageal adenocarcinoma develops in Barrett’s esophagus, and stomach cancer in chronic gastric atrophy with Helicobacter pylori infection. Colorectal cancer is favoured by a high intake in calories, excess weight, low physical activity. In opportunistic or individual screening endoscopy is the primary detection procedure offered to an asymptomatic individual. In organized or mass screening proposed by National Health Authorities to a population, endoscopy is performed only in persons found positive to a filter selection test. The indications of primary upper gastrointestinal endoscopy and colonoscopy in opportunistic screening are increasingly developing over the world. Organized screening trials are proposed in some regions of China at high risk for esophageal cancer; the selection test is cytology of a balloon or sponge scrapping; they are proposed in Japan for stomach cancer with photofluorography as a selection test; and in Europe, America and Japan; for colorectal cancer with the fecal occult blood test as a selection test. Organized screening trials in a country require an evaluation: the benefit of the intervention assessed by its impact on incidence and on the 5 year survival for the concerned tumor site; in addition a number of bias interfering with the evaluation have to be controlled. Drawbacks of screening are in the morbidity of the diagnostic and treatment procedures and in overdetection of none clinically relevant lesions. The strategy of endoscopic screening applies to early cancer and to benign adenomatous precursors of adenocarcinoma. Diagnostic endoscopy is conducted in 2 steps: at first detection of an abnormal area through changes in relief, in color or in the course of superficial capillaries; then characterization of the morphology of the lesion according to the Paris classification and prediction of the risk of malignancy and depth of invasion, with the help of chromoscopy, magnification and image processing with neutrophil bactericidal index or FICE. Then treatment decision offers 3 options according to histologic prediction: abstention, endoscopic resection, surgery. The rigorous quality control of endoscopy will reduce the miss rate of lesions and the occurrence of interval cancer. PMID:23293721

  15. Development of a fully automatic scheme for detection of masses in whole breast ultrasound images.

    PubMed

    Ikedo, Yuji; Fukuoka, Daisuke; Hara, Takeshi; Fujita, Hiroshi; Takada, Etsuo; Endo, Tokiko; Morita, Takako

    2007-11-01

    Ultrasonography has been used for breast cancer screening in Japan. Screening using a conventional hand-held probe is operator dependent and thus it is possible that some areas of the breast may not be scanned. To overcome such problems, a mechanical whole breast ultrasound (US) scanner has been proposed and developed for screening purposes. However, another issue is that radiologists might tire while interpreting all images in a large-volume screening; this increases the likelihood that masses may remain undetected. Therefore, the aim of this study is to develop a fully automatic scheme for the detection of masses in whole breast US images in order to assist the interpretations of radiologists and potentially improve the screening accuracy. The authors database comprised 109 whole breast US imagoes, which include 36 masses (16 malignant masses, 5 fibroadenomas, and 15 cysts). A whole breast US image with 84 slice images (interval between two slice images: 2 mm) was obtained by the ASU-1004 US scanner (ALOKA Co., Ltd., Japan). The feature based on the edge directions in each slice and a method for subtracting between the slice images were used for the detection of masses in the authors proposed scheme. The Canny edge detector was applied to detect edges in US images; these edges were classified as near-vertical edges or near-horizontal edges using a morphological method. The positions of mass candidates were located using the near-vertical edges as a cue. Then, the located positions were segmented by the watershed algorithm and mass candidate regions were detected using the segmented regions and the low-density regions extracted by the slice subtraction method. For the removal of false positives (FPs), rule-based schemes and a quadratic discriminant analysis were applied for the distribution between masses and FPs. As a result, the sensitivity of the authors scheme for the detection of masses was 80.6% (29/36) with 3.8 FPs per whole breast image. The authors scheme for a computer-aided detection may be useful in improving the screening performance and efficiency.

  16. Screening for skin cancer.

    PubMed

    Helfand, M; Mahon, S M; Eden, K B; Frame, P S; Orleans, C T

    2001-04-01

    Malignant melanoma is often lethal, and its incidence in the United States has increased rapidly over the past 2 decades. Nonmelanoma skin cancer is seldom lethal, but, if advanced, can cause severe disfigurement and morbidity. Early detection and treatment of melanoma might reduce mortality, while early detection and treatment of nonmelanoma skin cancer might prevent major disfigurement and to a lesser extent prevent mortality. Current recommendations from professional societies regarding screening for skin cancer vary. To examine published data on the effectiveness of routine screening for skin cancer by a primary care provider, as part of an assessment for the U.S. Preventive Services Task Force. We searched the MEDLINE database for papers published between 1994 and June 1999, using search terms for screening, physical examination, morbidity, and skin neoplasms. For information on accuracy of screening tests, we used the search terms sensitivity and specificity. We identified the most important studies from before 1994 from the Guide to Clinical Preventive Services, second edition, and from high-quality reviews. We used reference lists and expert recommendations to locate additional articles. Two reviewers independently reviewed a subset of 500 abstracts. Once consistency was established, the remainder were reviewed by one reviewer. We included studies if they contained data on yield of screening, screening tests, risk factors, risk assessment, effectiveness of early detection, or cost effectiveness. We abstracted the following descriptive information from full-text published studies of screening and recorded it in an electronic database: type of screening study, study design, setting, population, patient recruitment, screening test description, examiner, advertising targeted at high-risk groups or not targeted, reported risk factors of participants, and procedure for referrals. We also abstracted the yield of screening data including probabilities and numbers of referrals, types of suspected skin cancers, biopsies, confirmed skin cancers, and stages and thickness of skin cancers. For studies that reported test performance, we recorded the definition of a suspicious lesion, the "gold-standard" determination of disease, and the number of true positive, false positive, true negative, and false negative test results. When possible, positive predictive values, likelihood ratios, sensitivity, and specificity were recorded. No randomized or case-control studies have been done that demonstrate that routine screening for melanoma by primary care providers reduces morbidity or mortality. Basal cell carcinoma and squamous cell carcinoma are very common, but detection and treatment in the absence of formal screening are almost always curative. No controlled studies have shown that formal screening programs will improve this already high cure rate. While the efficacy of screening has not been established, the screening procedures themselves are noninvasive, and the follow-up test, skin biopsy, has low morbidity. Five studies from mass screening programs reported the accuracy of skin examination as a screening test. One of these, a prospective study, tracked patients with negative results to determine the number of patients with false-negative results. In this study, the sensitivity of screening for skin cancer was 94% and specificity was 98%. Several recent case-control studies confirm earlier evidence that risk of melanoma rises with the presence of atypical moles and/or many common moles. One well-done prospective study demonstrated that risk assessment by limited physical exam identified a relatively small (<10%) group of primary care patients for more thorough evaluation. The quality of the evidence addressing the accuracy of routine screening by primary care providers for early detection of melanoma or nonmelanoma skin cancer ranged from poor to fair. We found no studies that assessed the effectiveness of periodic skin examination by a clinician in reducing melanoma mortality. Both self-assessment of risk factors or clinician examination can classify a small proportion of patients as at highest risk for melanoma. Skin cancer screening, perhaps using a risk-assessment technique to identify high-risk patients who are seeing a physician for other reasons, merits additional study as a strategy to address the excess burden of disease in older adults.

  17. Screening for prostate cancer: are digital rectal examinations being performed?

    PubMed

    Federman, Daniel G; Pitkin, Patricia; Carbone, Vera; Concato, John; Kravetz, Jeffrey D

    2014-04-01

    Prostate cancer is common and prostate cancer screening is controversial; this retrospective observational study was conducted to determine the prevalence of digital rectal examination (DRE) in those in whom a prostate-specific antigen (PSA) test was performed. A manual review was performed of the electronic medical record for male veterans in the VA Connecticut Healthcare System without a history of known prostate cancer aged between 50 and 74 years who underwent PSA testing. Documentation of DRE (or refusal) within 12 months before or after the performance of a PSA test. Less than half (47.6%) of patients underwent DRE. An additional 6.9% were offered DRE and refused. Although the provider gender was not associated with DRE, resident physicians were less likely to perform DRE than nonresidents; P = 0.01. Patients whose PSA was > 4.0 ng/mL were more likely to undergo DRE than those whose PSA was ≤ 4.0 ng/mL; P = 0.002. Those with body mass index (BMI) > 40 kg/m 2 were less likely to undergo DRE than those with BMI < 30 kg/m 2 ; P = 0.04. Screening for prostate cancer remains controversial. We found a low rate of DRE among veterans in whom prostate cancer screening was entertained. Although the provider gender does not seem to influence DRE, resident physicians were less likely to perform DRE than other providers. Our finding that BMI > 40 kg/m 2 is associated with a lower rate of DRE than those with BMI < 30 kg/m 2 is consistent with screening for other cancers and should be explored further.

  18. Generic sample preparation combined with high-resolution liquid chromatography-time-of-flight mass spectrometry for unification of urine screening in doping-control laboratories.

    PubMed

    Peters, R J B; Oosterink, J E; Stolker, A A M; Georgakopoulos, C; Nielen, M W F

    2010-04-01

    A unification of doping-control screening procedures of prohibited small molecule substances--including stimulants, narcotics, steroids, beta2-agonists and diuretics--is highly urgent in order to free resources for new classes such as banned proteins. Conceptually this may be achieved by the use of a combination of one gas chromatography-time-of-flight mass spectrometry method and one liquid chromatography-time-of-flight mass spectrometry method. In this work a quantitative screening method using high-resolution liquid chromatography in combination with accurate-mass time-of-flight mass spectrometry was developed and validated for determination of glucocorticosteroids, beta2-agonists, thiazide diuretics, and narcotics and stimulants in urine. To enable the simultaneous isolation of all the compounds of interest and the necessary purification of the resulting extracts, a generic extraction and hydrolysis procedure was combined with a solid-phase extraction modified for these groups of compounds. All 56 compounds are determined using positive electrospray ionisation with the exception of the thiazide diuretics for which the best sensitivity was obtained by using negative electrospray ionisation. The results show that, with the exception of clenhexyl, procaterol, and reproterol, all compounds can be detected below the respective minimum required performance level and the results for linearity, repeatability, within-lab reproducibility, and accuracy show that the method can be used for quantitative screening. If qualitative screening is sufficient the instrumental analysis may be limited to positive ionisation, because all analytes including the thiazides can be detected at the respective minimum required levels in the positive mode. The results show that the application of accurate-mass time-of-flight mass spectrometry in combination with generic extraction and purification procedures is suitable for unification and expansion of the window of screening methods of doping laboratories. Moreover, the full-scan accurate-mass data sets obtained still allow retrospective examination for emerging doping agents, without re-analyzing the samples.

  19. A Label-Free Porous Silicon Immunosensor for Broad Detection of Opiates in a Blind Clinical Study and Result Comparison to Commercial Analytical Chemistry Techniques

    PubMed Central

    Bonanno, Lisa M.; Kwong, Tai C.; DeLouise, Lisa A.

    2010-01-01

    In this work we evaluate for the first time the performance of a label-free porous silicon (PSi) immunosensor assay in a blind clinical study designed to screen authentic patient urine specimens for a broad range of opiates. The PSi opiate immunosensor achieved 96% concordance with liquid chromatography-mass spectrometry/tandem mass spectrometry (LC-MS/MS) results on samples that underwent standard opiate testing (n=50). In addition, successful detection of a commonly abused opiate, oxycodone, resulted in 100% qualitative agreement between the PSi opiate sensor and LC-MS/MS. In contrast, a commercial broad opiate immunoassay technique (CEDIA®) achieved 65% qualitative concordance with LC-MS/MS. Evaluation of important performance attributes including precision, accuracy, and recovery was completed on blank urine specimens spiked with test analytes. Variability of morphine detection as a model opiate target was < 9% both within-run and between-day at and above the cutoff limit of 300 ng ml−1. This study validates the analytical screening capability of label-free PSi opiate immunosensors in authentic patient samples and is the first semi-quantitative demonstration of the technology’s successful clinical use. These results motivate future development of PSi technology to reduce complexity and cost of diagnostic testing particularly in a point-of-care setting. PMID:21062030

  20. Rapid screening, identification, and purification of neuraminidase inhibitors from Lithospermum erythrorhizon Sieb.et Zucc. by ultrafiltration with HPLC-ESI-TOF-MS combined with semipreparative HPLC.

    PubMed

    Zhang, Minmin; Zhao, Hengqiang; Zhao, Zhiguo; Yan, Huijiao; Lv, Ruimin; Cui, Li; Yuan, Jinpeng; Wang, Daijie; Geng, Yanling; Liu, Daicheng; Wang, Xiao

    2016-06-01

    We put forward an efficient strategy based on bioassay guidance for the rapid screening, identification, and purification of the neuraminidase inhibitors from traditional Chinese medicines, and apply to the discovery of anti-influenza components from Lithospermiun erythrorhizon Sieb.et Zucc. Ultrafiltration with high-performance liquid chromatography and electrospray ionization time-of-flight mass spectrometry was employed for the rapid screening and preliminarily identification of anti-influenza components from Zicao. Semipreparative high-performance liquid chromatography was used for the rapid separation and purification of the target compounds. NMR spectroscopy, mass spectrometry, and UV spectroscopy were used for further structural identification, and the activity of the compounds was verified by in vitro assay. Five compounds were found to have neuraminidase inhibitory activity by this method. Subsequently, the five compounds were separated by semipreparative high-performance liquid chromatography with the purity over 98% for all of them by high-performance liquid chromatography test. Combined with the NMR spectroscopy, mass spectrometry, and UV spectroscopy data, they were identified as alkannin, acetylalkannin, isobutyrylalkannin, β,β-dimethylacryloylalkannin and isovalerylalkannin. The in vitro assay showed that all five compounds had good neuraminidase inhibitory activities. These results suggested that the method is highly efficient, and it can provide platform and methodology supports for the rapid discovery of anti-influenza active ingredients from complex Chinese herbal medicines. © 2016 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  1. Screen time, cardiorespiratory fitness and adiposity among school-age children from Monteria, Colombia.

    PubMed

    Arango, Carlos M; Parra, Diana C; Gómez, Luis F; Lema, Lucía; Lobelo, Felipe; Ekelund, Ulf

    2014-09-01

    To explore the association between electronic media exposure (television viewing time, personal computer/video game use, total screen time), and waist circumference and body mass index, and study whether this association is independent of cardiorespiratory fitness, in a representative sample of adolescents from Montería, Colombia. Cross-sectional study analyzing data from 546 students aged 11-18 years, from fourteen randomly selected schools. Z-scores for WC and BMI were calculated. The physical activity module of the Global School Health Survey 2007 was used to determine EME, and the shuttle run test was used to assess CRF. Linear regression models adjusted by age, school location, physical activity level, type of institution (public or private), consumption of sweetened beverages, fast food, and fried food were used. Among boys, independently of cardiorespiratory fitness, high television viewing time (≥ 2 h/day) (β=+0.22; p<0.02), was positively associated with waist circumference. High total screen time (>3h/day) was positively associated with waist circumference (β=+0.34; p<0.01), and body mass index (β=+0.39; p<0.01). Among girls, sedentary behavior was not associated with adiposity, but cardiorespiratory fitness (β=-0.04; p<0.02) was negatively associated with body mass index. These findings support the evidence on the negative impact of excessive electronic media exposure and low cardiorespiratory fitness, and highlight the need for interventions and prevention strategies. Copyright © 2013 Sports Medicine Australia. All rights reserved.

  2. Type 2 diabetes mellitus in Navajo adolescents.

    PubMed Central

    Kim, C; McHugh, C; Kwok, Y; Smith, A

    1999-01-01

    Diabetes mellitus afflicts over one-fifth of the Navajo population aged over 20 years, but the prevalence of diabetes in Navajo adolescents is unclear. We conducted voluntary testing for diabetes mellitus at two high schools on the Navajo reservation to clarify the prevalence as well as to assess the utility of a high-school based screening program. Body mass index measurements (BMI), oral glucose tolerance tests, and hemoglobin A1C measurements were obtained in consenting high school students. Of the 276 students that participated, 234 were Navajo. Only one Navajo student (0.4%) had diabetes mellitus, although eight (3%) had impaired glucose tolerance or impaired fasting glucose. Participant BMI did not differ significantly from nonparticipant BMI. No correlation existed between BMI or impaired glucose handling, and significant overlap existed between the hemoglobin A1C values of students with impaired glucose handling and students without impaired glucose handling. Increased participation in screening programs may reveal higher disease prevalence, but high school-based screening is not justified by this study, despite the high rates of diabetes mellitus in the Navajo population. PMID:10344174

  3. Screening Methods for Metal-Containing Nanoparticles in Water

    EPA Science Inventory

    Screening-level analysis of water for metal-containing nanoparticles is achieved with single particle-inductively coupled plasma mass spectrometry (SP-ICPMS). This method measures both the concentration of nanoparticles containing an analyte metal and the mass of the metal in eac...

  4. Parents of elementary school students weigh in on height, weight, and body mass index screening at school.

    PubMed

    Kubik, Martha Y; Fulkerson, Jayne A; Story, Mary; Rieland, Gayle

    2006-12-01

    School-based body mass index (BMI) screening and parent notification programs have been recommended as a childhood overweight prevention strategy. However, there are little empirical data available to guide decision making about the acceptability and safety of programs. A pilot study was conducted using a quasiexperimental research design. In fall 2004, children in 4 suburban elementary schools (kindergarten to sixth grade) in the St Paul/Minneapolis, MN, metropolitan area completed height/weight screening. The following spring, parents in 2 schools received letters containing height/weight and BMI results. A self-administered post-only survey examined parents' opinions and beliefs regarding school-based BMI screening and parent notification programs (response rate: 790/1133 = 70%). The chi2 test of significance was used to examine differences in program support by treatment condition, child's weight status, and sociodemographic characteristics. Among all parents, 78% believed it was important for schools to assess student's height/weight annually and wanted to receive height, weight, and BMI information yearly. Among parents receiving the letter, 95% read most/all of the letter. Most parents (80%) and children (83%) reported comfort with the information in the letter. Parents of overweight children were more likely to report parental discomfort as well as child discomfort with letter content. There was considerable parental support for school-based BMI screening and parent notification programs. Programs may be a useful overweight prevention tool for children. However, continued attention to how best to support parents and children affected by overweight is required.

  5. Surveillance of chronic obstructive pulmonary disease in high-risk individuals by using regional lung cancer mass screening.

    PubMed

    Sekine, Yasuo; Yanagibori, Ryoko; Suzuki, Kiminori; Sugiyama, Sonomi; Yamaji, Haruko; Ishibashi, Michiko; Fujisawa, Takehiko

    2014-01-01

    Patients with chronic obstructive pulmonary disease (COPD) are at risk for lung cancer; the diseases have common etiologies, including cigarette smoking. We aimed to clarify the effectiveness of COPD detection using a regional mass-screening program for lung cancer. A total of 7,067 residents of Togane, Chiba, Japan received lung cancer screening between May and July, 2011. We defined four groups of possible COPD candidates: group A (n=358), positive smoking history, positive chronic respiratory symptoms; group B (n=766), positive smoking history, positive lifestyle-related disease; group C (n=75), passive smoking history, positive chronic respiratory symptoms; and group D (n=301), passive smoking history, positive lifestyle-related disease. Candidates underwent on-site pulmonary function testing (PFT). The criteria for COPD candidates were fulfilled in 1,686 of 7,067 individuals (23.9%); 1,500 participants underwent PFT (89%), and 171 (11.4%) were diagnosed with COPD. The overall COPD detection rate was 2.4%. The frequency of COPD was significantly higher in groups A and B than in groups C and D (P=0.048); however, the distribution of COPD grades was similar among the groups (P=0.372). Multiple logistic regression analysis identified male sex, age 60 years or greater, and positive smoking history as risk factors for COPD. COPD screening using a community-based lung cancer-screening program may be effective for disease detection. Individuals who are 60 years of age or older with a positive smoking history should undergo PFT to detect COPD.

  6. Molecular formula and METLIN Personal Metabolite Database matching applied to the identification of compounds generated by LC/TOF-MS.

    PubMed

    Sana, Theodore R; Roark, Joseph C; Li, Xiangdong; Waddell, Keith; Fischer, Steven M

    2008-09-01

    In an effort to simplify and streamline compound identification from metabolomics data generated by liquid chromatography time-of-flight mass spectrometry, we have created software for constructing Personalized Metabolite Databases with content from over 15,000 compounds pulled from the public METLIN database (http://metlin.scripps.edu/). Moreover, we have added extra functionalities to the database that (a) permit the addition of user-defined retention times as an orthogonal searchable parameter to complement accurate mass data; and (b) allow interfacing to separate software, a Molecular Formula Generator (MFG), that facilitates reliable interpretation of any database matches from the accurate mass spectral data. To test the utility of this identification strategy, we added retention times to a subset of masses in this database, representing a mixture of 78 synthetic urine standards. The synthetic mixture was analyzed and screened against this METLIN urine database, resulting in 46 accurate mass and retention time matches. Human urine samples were subsequently analyzed under the same analytical conditions and screened against this database. A total of 1387 ions were detected in human urine; 16 of these ions matched both accurate mass and retention time parameters for the 78 urine standards in the database. Another 374 had only an accurate mass match to the database, with 163 of those masses also having the highest MFG score. Furthermore, MFG calculated a formula for a further 849 ions that had no match to the database. Taken together, these results suggest that the METLIN Personal Metabolite database and MFG software offer a robust strategy for confirming the formula of database matches. In the event of no database match, it also suggests possible formulas that may be helpful in interpreting the experimental results.

  7. Direct sampling of chemical weapons in water by photoionization mass spectrometry.

    PubMed

    Syage, Jack A; Cai, Sheng-Suan; Li, Jianwei; Evans, Matthew D

    2006-05-01

    The vulnerability of water supplies to toxic contamination calls for fast and effective means for screening water samples for multiple threats. We describe the use of photoionization (PI) mass spectrometry (MS) for high-speed, high-throughput screening and molecular identification of chemical weapons (CW) threats and other hazardous compounds. The screening technology can detect a wide range of compounds at subacute concentrations with no sample preparation and a sampling cycle time of approximately 45 s. The technology was tested with CW agents VX, GA, GB, GD, GF, HD, HN1, and HN3, in addition to riot agents and precursors. All are sensitively detected and give simple PI mass spectra dominated by the parent ion. The target application of the PI MS method is as a routine, real-time early warning system for CW agents and other hazardous compounds in air and in water. In this work, we also present comprehensive measurements for water analysis and report on the system detection limits, linearity, quantitation accuracy, and false positive (FP) and false negative rates for concentrations at subacute levels. The latter data are presented in the form of receiver operating characteristic curves of the form of detection probability P(D) versus FP probability P(FP). These measurements were made using the CW surrogate compounds, DMMP, DEMP, DEEP, and DIMP. Method detection limits (3sigma) obtained using a capillary injection method yielded 1, 6, 3, and 2 ng/mL, respectively. These results were obtained using 1-microL injections of water samples without any preparation, corresponding to mass detection limits of 1, 6, 3, and 2 pg, respectively. The linear range was about 3-4 decades and the dynamic range about 4-5 decades. The relative standard deviations were generally <10% at CW subacute concentrations levels.

  8. ColoNav: patient navigation for colorectal cancer screening in deprived areas - Study protocol.

    PubMed

    Allary, C; Bourmaud, A; Tinquaut, F; Oriol, M; Kalecinski, J; Dutertre, V; Lechopier, N; Pommier, M; Benoist, Y; Rousseau, S; Regnier, V; Buthion, V; Chauvin, F

    2016-07-07

    The mass colorectal cancer screening program was implemented in 2008 in France, targeting 16 million French people aged between 50 and 74. The current adhesion is insufficient and the participation rate is even lower among the underserved population, increasing health inequalities within our health care system. Patient Navigation programs have proved their efficiency to promote the access to cancer screening and diagnosis. The purpose of the study is to assess the implementation of a patient navigation intervention that has been described in another cultural environment and another health care system. The main objective of the program is to increase the colorectal cancer screening participation rate among the deprived population through the intervention of a navigator to promote the Fecal Occult Blood Test (FOBT) and complementary exams. We performed a multisite cluster randomized controlled trial, with three groups (one experimental group and two control groups) for 18 months. The study attempts to give a better understanding of the adhesion barriers to colorectal cancer screening among underserved populations. If this project is cost-effective, it could create a dynamic based on peer approaches that could be developed for other cancer screening programs and other chronic diseases. NCT02369757.

  9. Talent identification model for sprinter using discriminant factor

    NASA Astrophysics Data System (ADS)

    Kusnanik, N. W.; Hariyanto, A.; Herdyanto, Y.; Satia, A.

    2018-01-01

    The main purpose of this study was to identify young talented sprinter using discriminant factor. The research was conducted in 3 steps including item pool, screening of item pool, and trial of instruments at the small and big size of samples. 315 male elementary school students participated in this study with mean age of 11-13 years old. Data were collected by measuring anthropometry (standing height, sitting height, body mass, and leg length); testing physical fitness (40m sprint for speed, shuttle run for agility, standing broad jump for power, multistage fitness test for endurance). Data were analyzed using discriminant factor. The result of this study found that there were 5 items that selected as an instrument to identify young talented sprinter: sitting height, body mass, leg length, sprint 40m, and multistage fitness test. Model of Discriminant for talent identification in sprinter was D = -24,497 + (0,155 sitting height) + (0,080 body mass) + (0,148 leg length) + (-1,225 Sprint 40m) + (0,563 MFT). The conclusion of this study: instrument tests that have been selected and discriminant model that have been found can be applied to identify young talented as a sprinter.

  10. Evaluation of the Triage TOX Drug Screen Assay for Detection of 11 Drugs of Abuse and Therapeutic Drugs.

    PubMed

    Bang, Hae In; Jang, Mi Ae; Lee, Yong Wha

    2017-11-01

    The demand for rapid and broad clinical toxicology screens is on the rise. Recently, a new rapid toxicology screening test, the Triage TOX Drug Screen (Alere Inc., USA), which can simultaneously detect 11 drugs of abuse and therapeutic drugs with an instrument-read cartridge, was developed. In the present study, we evaluated the efficacy of this new on-site immunoassay using 105 urine specimens; the results were compared with those obtained by using ultra-performance liquid chromatography with tandem mass spectrometry (UPLC-TMS). Precision was evaluated according to the CLSI EP12-A2 for analyte concentrations near the cutoff, including C₅₀ and±30% of C₅₀, for each drug using standard materials. The C₅₀ specimens yielded 35-65% positive results and the±30% concentration range of all evaluated drugs encompassed the C₅-C₉₅ interval. The overall percent agreement of the Triage TOX Drug Screen was 92.4-100% compared with UPLC-TMS; however, the Triage TOX Drug Screen results showed some discordant cases including acetaminophen, amphetamine, benzodiazepine, opiates, and tricyclic antidepressants. The overall performance of the Triage TOX Drug Screen assay was comparable to that of UPLC-TMS for screening of drug intoxication in hospitals. This assay could constitute a useful screening method for drugs of abuse and therapeutic drugs in urine. © The Korean Society for Laboratory Medicine.

  11. Periodic health examination, 1995 update: 1. Screening for human papillomavirus infection in asymptomatic women. Canadian Task Force on the Periodic Health Examination.

    PubMed

    Johnson, K

    1995-02-15

    To develop recommendations for practising physicians on the advisability of screening for human papillomavirus (HPV) infection in asymptomatic women. Visual inspection, Papanicolaou testing, colposcopy or cervicography, use of HPV group-specific antigen, DNA hybridization, dot blot technique, Southern blot technique or polymerase chain reaction followed by physical or chemical therapeutic intervention. Evidence for a link between HPV infection and cervical cancer, sensitivity and specificity of HPV screening techniques, effectiveness of treatments for HPV infection, and the social and economic costs incurred by screening. MEDLINE was searched for articles published between January 1966 to June 1993 with the use of the key words "papillomavirus," "cervix neoplasms," "mass screening," "prospective studies," "prevalence," "sensitivity," "specificity," "human" and "female." Proven cost-effective screening techniques that could lead to decreased morbidity or mortality were given a high value. The evidence-based methods and values of the Canadian Task Force on the Periodic Health Examination were used. Potential benefits are to prevent cervical cancer and eliminate HPV infection. Potential harmful effects include the creation of an unnecessary burden on the health care system and the labelling of otherwise healthy people as patients with a sexually transmitted disease for which therapy is generally ineffective. Potential costs would include expense of testing, increased use of colposcopy and treatment. There is fair evidence to exclude HPV screening (beyond Papanicolaou testing for cervical cancer) in asymptomatic women (grade D recommendation). The report was reviewed by members of the task force and three external reviewers who were selected to represent different areas of expertise. These guidelines were developed and endorsed by the task force, which is funded by Health Canada and the National Health Research and Development Program. The principal author (K.J.) was supported in part by the National Health Research and Development Program through a National Health Fellowship (AIDS).

  12. Webinar Presentation: Suspect Screening of Environmental Organic Acids in Human Serum Using High-resolution Mass Spectrometry (HRMS)

    EPA Pesticide Factsheets

    This presentation, Suspect Screening of Environmental Organic Acids in Human Serum Using High-resolution Mass Spectrometry (HRMS), was given at the NIEHS/EPA Children's Centers 2016 Webinar Series: Exposome held on May 11, 2016.

  13. Using Weighted Entropy to Rank Chemicals in Quantitative High Throughput Screening Experiments

    PubMed Central

    Shockley, Keith R.

    2014-01-01

    Quantitative high throughput screening (qHTS) experiments can simultaneously produce concentration-response profiles for thousands of chemicals. In a typical qHTS study, a large chemical library is subjected to a primary screen in order to identify candidate hits for secondary screening, validation studies or prediction modeling. Different algorithms, usually based on the Hill equation logistic model, have been used to classify compounds as active or inactive (or inconclusive). However, observed concentration-response activity relationships may not adequately fit a sigmoidal curve. Furthermore, it is unclear how to prioritize chemicals for follow-up studies given the large uncertainties that often accompany parameter estimates from nonlinear models. Weighted Shannon entropy can address these concerns by ranking compounds according to profile-specific statistics derived from estimates of the probability mass distribution of response at the tested concentration levels. This strategy can be used to rank all tested chemicals in the absence of a pre-specified model structure or the approach can complement existing activity call algorithms by ranking the returned candidate hits. The weighted entropy approach was evaluated here using data simulated from the Hill equation model. The procedure was then applied to a chemical genomics profiling data set interrogating compounds for androgen receptor agonist activity. PMID:24056003

  14. Evaluation of Abdominal Ultrasonography Mass Screening for Hepatocellular Carcinoma in Taiwan

    PubMed Central

    Yeh, Yen-Po; Hu, Tsung-Hui; Cho, Po-Yuan; Chen, Hsiu-Hsi; Yen, Amy Ming-Fang; Chen, Sam Li-Sheng; Chiu, Sherry Yueh-Hsia; Fann, Jean Ching-Yuan; Su, Wei-Wen; Fang, Yi-Jen; Chen, Shih-Tien; San, Hsiao-Ching; Chen, Hung-Pin; Liao, Chao-Sheng

    2014-01-01

    Mass screening with abdominal ultrasonography (AUS) has been suggested as a tool to control adult hepatocellular carcinoma (HCC) in individuals, but its efficacy in reducing HCC mortality has never been demonstrated. This study aimed to assess the effectiveness of reducing HCC mortality by mass AUS screening for HCC based on a program designed and implemented in the Changhua Community-based Integrated Screening (CHCIS) program with an efficient invitation scheme guided by the risk score. We invited 11,114 (27.0%) of 41,219 eligible Taiwanese subjects between 45 and 69 years of age who resided in an HCC high-incidence area to attend a risk score-guided mass AUS screening between 2008 and 2010. The efficacy of reducing HCC mortality was estimated. Of the 8,962 AUS screening attendees (with an 80.6% attendance rate), a total of 16 confirmed HCC cases were identified through community-based ultrasonography screening. Among the 16 screen-detected HCC cases, only two died from HCC, indicating a favorable survival. The cumulative mortality due to HCC (per 100,000) was considerably lower in the invited AUS group (17.26) compared with the uninvited AUS group (42.87) and the historical control group (47.51), yielding age- and gender-adjusted relative mortality rates of 0.69 (95% confidence interval [CI]: 0.56-0.84) and 0.63 (95% CI: 0.52-0.77), respectively. Conclusion: The residents invited to community-based AUS screening for HCC, compared with those who were not invited, showed a reduction in HCC mortality by ∼31% among subjects aged 45-69 years who had not been included in the nationwide vaccination program against hepatitis B virus infection. (Hepatology 2014;59:1840–1849) PMID:24002724

  15. Screen time and adiposity in adolescents in Mexico

    PubMed Central

    Lajous, Martín; Chavarro, Jorge; Peterson, Karen E; Hernández-Prado, Bernardo; Cruz-Valdéz, Aurelio; Hernández-Ávila, Mauricio; Lazcano-Ponce, Eduardo

    2014-01-01

    Objective To assess the association of time spent viewing television, videos and videogames with measures of fat mass [body mass index (BMI)] and distribution [triceps and subscapular skin folds (TSF, SSF)]. Design Cross-sectional validated survey, self-administered to students to assess screen time (TV, videos and videogames) and lifestyle variables. Trained personnel obtained anthropometry. The association of screen time with fat mass and distribution, stratified by sex, was modeled with multivariable linear regression, adjusting for potential confounders and correlation of observations within schools. Subjects and setting 3519 males and 5613 females aged 11 to 18 years attending urban and rural schools in the State of Morelos, Mexico Results In males, ≥5 hr/day compared with < 2 hr/day of screen time, was significantly associated with a 0.13 (95%CI 0.04, 0.23) higher BMI z score, 0.73 mm (95% CI 0.24, 1.22) higher SSF and 1.08 mm (95% CI 0.36, 1.81) higher TSF. The positive association of screen time with SSF was strongest in males 11–12 yr. Sexual maturity appeared to modify the association in females; a positive between screen time and SSF was observed in those who had not undergone menarche (p-trend 0.04) but not among sexually mature females (p-trend 0.75). Conclusion Screen time is associated with fat mass and distribution among adolescent males in Mexico. Maturational tempo appears to affect the relationship of screen time with adiposity in boys and girls. Findings suggest obesity preventive interventions in the Mexican context should explore strategies to reduce screen time among youth in early adolescence. PMID:19232154

  16. Bioimpedance analysis vs. DEXA as a screening tool for osteosarcopenia in lean, overweight and obese Caucasian postmenopausal females.

    PubMed

    Peppa, Melpomeni; Stefanaki, Charikleia; Papaefstathiou, Athanasios; Boschiero, Dario; Dimitriadis, George; Chrousos, George P

    2017-04-01

    We aimed at evaluating the efficiency of a newly developed, advanced Bioimpedance Analysis (BIA-ACC®) device as a screening tool for determining the degree of obesity and osteosarcopenia in postmenopausal women with normal or decreased bone density determined by Dual-Energy X-Ray absorptiometry (DEXA) in a representative sample of Greek postmenopausal women. This is a single-gate cross-sectional study of body composition measured by BIA-ACC® and DEXA. Postmenopausal females with BMI ranging from 18.5 to 40 kg/m2 were subjected to two consecutive measurements of DEXA and BIA-ACC® within 5-10 minutes of each other. We used Pearson's co-efficient to examine linear correlations, the intraclass correlation co-efficient (ICC) to test reliability, Bland-Atman plots to assess bias and Deming regressions to establish the agreement in parameters measured by BIA-ACC® and DEXA. Last, we used ANOVA, with Bonferroni correction and Dunnett T3 post hoc tests, for assessing the differences between quantitative and Pearson's x2 between qualitative variables. Our sample consisted of 84 overweight/obese postmenopausal women, aged 39-83 years, of whom 22 had normal bone density, 38 had osteopenia and 24 had osteoporosis based on DEXA measurements, using quota sampling. ICCs and Deming regressions showed strong agreement between BIA-ACC® and DEXA and demonstrated minimal proportional differences of no apparent clinical significance. Bland-Altman plots indicated minimal biases. Fat, skeletal and bone mass measured by BIA-ACC® and DEXA were increased in the non-osteopenic/non-osteoporotic women compared with those of the osteopenic and osteoporotic groups. BIA-ACC® is a rapid, bloodless and useful screening tool for determining body composition adiposity and presence of osteo-sarcopenic features in postmenopausal women. Women with osteopenia and osteoporosis evaluated by DEXA had decreased fat, skeletal and bone mass compared with normal bone density women, suggesting concordance in the change of these three organ masses in postmenopausal women.

  17. Coeliac disease in a 15-year period of observation (1997 and 2011) in a Hungarian referral centre.

    PubMed

    Kocsis, Dorottya; Miheller, Pál; Lőrinczy, Katalin; Herszényi, László; Tulassay, Zsolt; Rácz, Károly; Juhász, Márk

    2013-07-01

    The aim of this study is to evaluate the experience of a single coeliac centre over a 15-year-long study period (between November of 1997 and September of 2011). Charts of 178 patients (139 females) with coeliac disease were retrospectively evaluated. Tests performed: multiple duodenal biopsies, anti-tissue transglutaminase and anti-endomysium antibodies, body mass index calculation, osteodensitometry, evaluation of disorders associated with coeliac disease, and implementation of family screening. Histological samples were available in 133 cases, distribution according to Marsh-Oberhuber classification: M0 in 7%, M1-M2 in 4%, M3a in 26%, M3b in 13%, and M3c in 50% of cases, respectively. Anti-tissue transglutaminase and anti-endomysium antibody tests were available in 158 cases, 132/158 showed seropositivity. Mean body mass index values were 23.05kg/m(2) for males, and 21.07kg/m(2) for females, respectively. Osteodensitometry showed normal values in 46%, osteopenia in 36%, and osteoporosis in 18% of cases, respectively. Coeliac disease associated disorders was present in 63/178 (35%) patients. Ninety coeliacs brought 197 first degree relatives for screening, with 47/197 (23%) relatives proving to have coeliac disease. Correlations between anti-tissue transglutaminase antibody titres and Marsh-Oberhuber classification, and anti-tissue transglutaminase antibody titres and bone mineral density values were found to be statistically significant (p=0.0011, and p=0.001, respectively). Coeliac disease can become overt at any age. Female predominance is significant. Histology usually showed advanced villous atrophy. Mean body mass index values were within normal range. The high prevalence of associated disorders is also noted. The prevalence of 24% of coeliac disease among first degree relatives underlines the necessity of family screening. Copyright © 2013 European Federation of Internal Medicine. Published by Elsevier B.V. All rights reserved.

  18. Screening for celiac disease in the general population and in high-risk groups

    PubMed Central

    Card, Timothy R; Kaukinen, Katri; Bai, Julio; Zingone, Fabiana; Sanders, David S; Murray, Joseph A

    2015-01-01

    Background Celiac disease (CD) occurs in approximately 1% of the Western population. It is a lifelong disorder that is associated with impaired quality of life (QOL) and an excessive risk of comorbidity and death. Objectives To review the literature on screening for CD in relation to the current World Health Organization (WHO) criteria for mass screening. Methods We performed a PubMed search to identify indexed papers on CD screening with a publication date from 1900 until 1 June 2014. When we deemed an abstract relevant, we read the corresponding paper in detail. Results CD fulfills several WHO criteria for mass screening (high prevalence, available treatment and difficult clinical detection), but it has not yet been established that treatment of asymptomatic CD may reduce the excessive risk of severe complications, leading to higher QOL nor that it is cost-effective. Conclusions Current evidence is not sufficient to support mass screening for CD, but active case-finding may be appropriate, as we recognize that most patients with CD will still be missed by this strategy. Although proof of benefit is still lacking, screening for CD may be appropriate in high-risk groups. PMID:25922671

  19. Clinical potential of proteomics in the diagnosis of ovarian cancer.

    PubMed

    Ardekani, Ali M; Liotta, Lance A; Petricoin, Emanuel F

    2002-07-01

    The need for specific and sensitive markers of ovarian cancer is critical. Finding a sensitive and specific test for its detection has an important public health impact. Currently, there are no effective screening options available for patients with ovarian cancer. CA-125, the most widely used biomarker for ovarian cancer, does not have a high positive predictive value and it is only effective when used in combination with other diagnostic tests. However, pathologic changes taking place within the ovary may be reflected in biomarker patterns in the serum. Combination of mass spectra generated by new proteomic technologies, such as surface-enhanced laser desorption ionization time-of-flight (SELDI-TOF) and artificial-intelligence-based informatic algorithms, have been used to discover a small set of key protein values and discriminate normal from ovarian cancer patients. Serum proteomic pattern analysis might be applied ultimately in medical screening clinics, as a supplement to the diagnostic work-up and evaluation.

  20. Screening for toxic phorbol esters in jerky pet treat products using LC-MS.

    PubMed

    Nishshanka, Upul; Jayasuriya, Hiranthi; Chattopadhaya, Chaitali; Kijak, Philip J; Chu, Pak-Sin; Reimschuessel, Renate; Tkachenko, Andriy; Ceric, Olgica; De Alwis, Hemakanthi G

    2016-05-01

    Since 2007, the U.S. FDA's Center for Veterinary Medicine (CVM) has been investigating reports of pets becoming ill after consuming jerky pet treats. Jerky used in pet treats contains glycerin, which can be made from vegetable oil or as a byproduct of biodiesel production. Because some biodiesel is produced using oil from Jatropha curcas, a plant that contains toxic compounds including phorbol esters, CVM developed a liquid chromatography-mass spectrometry (LC-MS) screening method to evaluate investigational jerky samples for the presence of these toxins. Results indicated that the samples analyzed with the new method did not contain Jatropha toxins at or above the lowest concentration tested. Published by Elsevier B.V.

  1. A Pharmacological Screening Approach for Discovery of Neuroprotective Compounds in Ischemic Stroke

    PubMed Central

    Beraki, Simret; Litrus, Lily; Soriano, Liza; Monbureau, Marie; To, Lillian K.; Braithwaite, Steven P.; Nikolich, Karoly; Urfer, Roman; Oksenberg, Donna; Shamloo, Mehrdad

    2013-01-01

    With the availability and ease of small molecule production and design continuing to improve, robust, high-throughput methods for screening are increasingly necessary to find pharmacologically relevant compounds amongst the masses of potential candidates. Here, we demonstrate that a primary oxygen glucose deprivation assay in primary cortical neurons followed by secondary assays (i.e. post-treatment protocol in organotypic hippocampal slice cultures and cortical neurons) can be used as a robust screen to identify neuroprotective compounds with potential therapeutic efficacy. In our screen about 50% of the compounds in a library of pharmacologically active compounds displayed some degree of neuroprotective activity if tested in a pre-treatment toxicity assay but just a few of these compounds, including Carbenoxolone, remained active when tested in a post-treatment protocol. When further examined, Carbenoxolone also led to a significant reduction in infarction size and neuronal damage in the ischemic penumbra when administered six hours post middle cerebral artery occlusion in rats. Pharmacological testing of Carbenoxolone-related compounds, acting by inhibition of 11-β-hydroxysteroid dehydrogenase-1 (11β-HSD1), gave rise to similarly potent in vivo neuroprotection. This indicates that the increase of intracellular glucocorticoid levels mediated by 11β-HSD1 may be involved in the mechanism that exacerbates ischemic neuronal cell death, and inhibiting this enzyme could have potential therapeutic value for neuroprotective therapies in ischemic stroke and other neurodegenerative disorders associated with neuronal injury. PMID:23874920

  2. A novel approach for noninvasive drug delivery and sensing through the amniotic sac.

    PubMed

    Azagury, Aharon; Amar-Lewis, Eliz; Mann, Ella; Goldbart, Riki; Traitel, Tamar; Jelinek, Raz; Hallak, Mordechai; Kost, Joseph

    2014-06-10

    Current invasive prenatal tests (amniocentesis and chorionic villus sampling) are known for their risk to the fetus. In the last decade, the use and awareness of these prenatal tests have increased, resulting in growing demand for a safe, non-invasive, and accurate prenatal test. Chemical penetration enhancers (CPEs) have long been used to increase transport phenomena across skin and other membranes (e.g., tympanic membrane). The amniotic sac membrane is called the chorioamnion (CA) membrane and serves as the physical barrier between the fetus and the mother. In this research, the effect of CPEs on human CA mass transport was evaluated both in vitro and ex vivo. The results show that the tested CPEs exhibit an enhancing effect on CA mass transport. Based on the permeability results, two mechanisms of action were suggested: "extractors" and "fluidizers". Fourier transform infrared (FTIR) and rapid colorimetric screening measurements supported the mechanisms, based on which, more potent compounds were designed and tested for their enhancing effect. The enhancing mass transport effect of CPEs on CA membrane may be used both for sampling of cell-free DNA and for noninvasively administering drugs and other biological agents to the amniotic sac. Copyright © 2014 Elsevier B.V. All rights reserved.

  3. The optimal sequence and selection of screening test items to predict fall risk in older disabled women: the Women's Health and Aging Study.

    PubMed

    Lamb, Sarah E; McCabe, Chris; Becker, Clemens; Fried, Linda P; Guralnik, Jack M

    2008-10-01

    Falls are a major cause of disability, dependence, and death in older people. Brief screening algorithms may be helpful in identifying risk and leading to more detailed assessment. Our aim was to determine the most effective sequence of falls screening test items from a wide selection of recommended items including self-report and performance tests, and to compare performance with other published guidelines. Data were from a prospective, age-stratified, cohort study. Participants were 1002 community-dwelling women aged 65 years old or older, experiencing at least some mild disability. Assessments of fall risk factors were conducted in participants' homes. Fall outcomes were collected at 6 monthly intervals. Algorithms were built for prediction of any fall over a 12-month period using tree classification with cross-set validation. Algorithms using performance tests provided the best prediction of fall events, and achieved moderate to strong performance when compared to commonly accepted benchmarks. The items selected by the best performing algorithm were the number of falls in the last year and, in selected subpopulations, frequency of difficulty balancing while walking, a 4 m walking speed test, body mass index, and a test of knee extensor strength. The algorithm performed better than that from the American Geriatric Society/British Geriatric Society/American Academy of Orthopaedic Surgeons and other guidance, although these findings should be treated with caution. Suggestions are made on the type, number, and sequence of tests that could be used to maximize estimation of the probability of falling in older disabled women.

  4. Investigation of blood lead concentrations in dogs living in Flint, Michigan.

    PubMed

    Langlois, Daniel K; Kaneene, John B; Yuzbasiyan-Gurkan, Vilma; Daniels, Barbara L; Mejia-Abreu, Hilda; Frank, Nancy A; Buchweitz, John P

    2017-10-15

    OBJECTIVE To measure blood lead concentrations (BLCs) in dogs living in Flint, Mich, following a declared water crisis and to assess potential associations of BLCs with demographic data, water sources, and clinical signs in these dogs. DESIGN Cross-sectional study. ANIMALS 284 dogs residing in Flint, Mich (test population), and 47 dogs residing in East Lansing, Mich (control population), and immediately adjacent areas. PROCEDURES Blood samples were collected at free screening clinics in Flint (test population) and at the Michigan State University College of Veterinary Medicine Veterinary Medical Center (control population). Owners of test population dogs completed questionnaires providing demographic and clinical information. Hematologic evaluations were performed; BLCs were measured by inductively coupled plasma-mass spectrometry. RESULTS 4 of 284 test population dogs had BLCs > 50 ppb; an additional 20 had BLCs > 20 ppb. Overall, BLCs of test population dogs were higher than those of control dogs. Within the test population, young dogs (≤ 2 years of age) had higher BLCs than old dogs (≥ 6 years of age). Only 7.2% of test population dogs were drinking unfiltered tap water at the time of screening; however, dogs that had been receiving filtered or bottled water for ≤ 3 months before screening had higher BLCs than did those that received such water for > 3 months. CONCLUSIONS AND CLINICAL RELEVANCE Taken together, findings suggested that the impact of the Flint water crisis extended to companion animals. Results highlighted the importance of maintaining awareness of lead exposure and considering both human and animal well-being in cases of environmental toxicant exposures.

  5. Osteoporosis: should there be a screening programme in Hong Kong?

    PubMed

    Hui, Y

    2002-08-01

    Osteoporosis is rapidly becoming a major health problem in Hong Kong with the ever-increasing population of elderly people. Its importance lies in the predisposition to fragility fractures of patients with the disease. These fractures incur morbidity and mortality to the elderly. Measures are needed to reduce the prevalence of osteoporosis and the incidence of osteoporotic fractures. A screening programme is potentially the way forward in achieving such a goal. The need for, and the feasibility of, a screening programme for osteoporosis in Hong Kong were evaluated. A comprehensive examination of the relevant issues was carried out within the framework of the World Health Organization criteria on screening of diseases. Major studies from abroad and Hong Kong were discussed and the strength of evidence was assessed. Osteoporosis satisfies some of the World Health Organization criteria for screening of diseases: it is a significant health problem, the natural history is fairly well understood, and early detection is possible. Nevertheless, there remain unresolved issues related to the screening tests, the treatments currently available, and the selection criteria for treatment. Several therapeutic options have been tested in trials. However, more work is needed to determine whether, in addition to increasing bone mass, they reduce the incidence of fracture. Moreover, the duration of therapy needed to achieve long-term benefit has yet to be established. More studies are also needed to evaluate the cost-effectiveness of such a programme. There undoubtedly needs to be a means of identifying individuals who have osteoporosis and are susceptible to fragility fractures. However, based on the currently available evidence, large-scale screening is not a valid option. Before instituting such a programme in Hong Kong, more studies are needed to determine the most appropriate and cost-effective way forward.

  6. What are the characteristics of breast cancers misclassified as benign by quantitative ultrasound shear wave elastography?

    PubMed

    Vinnicombe, S J; Whelehan, P; Thomson, K; McLean, D; Purdie, C A; Jordan, L B; Hubbard, S; Evans, A J

    2014-04-01

    Shear wave elastography (SWE) is a promising adjunct to greyscale ultrasound in differentiating benign from malignant breast masses. The purpose of this study was to characterise breast cancers which are not stiff on quantitative SWE, to elucidate potential sources of error in clinical application of SWE to evaluation of breast masses. Three hundred and two consecutive patients examined by SWE who underwent immediate surgery for breast cancer were included. Characteristics of 280 lesions with suspicious SWE values (mean stiffness >50 kPa) were compared with 22 lesions with benign SWE values (<50 kPa). Statistical significance of the differences was assessed using non-parametric goodness-of-fit tests. Pure ductal carcinoma in situ (DCIS) masses were more often soft on SWE than masses representing invasive breast cancer. Invasive cancers that were soft were more frequently: histological grade 1, tubular subtype, ≤10 mm invasive size and detected at screening mammography. No significant differences were found with respect to the presence of invasive lobular cancer, vascular invasion, hormone and HER-2 receptor status. Lymph node positivity was less common in soft cancers. Malignant breast masses classified as benign by quantitative SWE tend to have better prognostic features than those correctly classified as malignant. • Over 90 % of cancers assessable with ultrasound have a mean stiffness >50 kPa. • 'Soft' invasive cancers are frequently small (≤10 mm), low grade and screen-detected. • Pure DCIS masses are more often soft than invasive cancers (>40 %). • Large symptomatic masses are better evaluated with SWE than small clinically occult lesions. • When assessing small lesions, 'softness' should not raise the threshold for biopsy.

  7. Search for Screened Interactions Associated with Dark Energy below the 100 μm Length Scale.

    PubMed

    Rider, Alexander D; Moore, David C; Blakemore, Charles P; Louis, Maxime; Lu, Marie; Gratta, Giorgio

    2016-09-02

    We present the results of a search for unknown interactions that couple to mass between an optically levitated microsphere and a gold-coated silicon cantilever. The scale and geometry of the apparatus enable a search for new forces that appear at distances below 100  μm and which would have evaded previous searches due to screening mechanisms. The data are consistent with electrostatic backgrounds and place upper limits on the strength of new interactions at <0.1  fN in the geometry tested. For the specific example of a chameleon interaction with an inverse power law potential, these results exclude matter couplings β>5.6×10^{4} in the region of parameter space where the self-coupling Λ≳5  meV and the microspheres are not fully screened.

  8. Obstructive sleep apnea in North American commercial drivers.

    PubMed

    Kales, Stefanos N; Straubel, Madeleine G

    2014-01-01

    The most common medical cause of excessive daytime sleepiness (EDS) is obstructive sleep apnea (OSA). Specifically, among an estimated 14 million US commercial drivers, 17-28% or 2.4 to 3.9 million are expected to have OSA. Based on existing epidemiologic evidence, most of these drivers are undiagnosed and not adequately treated. Untreated OSA increases the risk of vehicular crashes as documented in multiple independent studies and by meta-analysis. Therefore, identifying commercial drivers with OSA and having them effectively treated should decrease crash-related fatalities and injuries. Several strategies are available for screening and identifying drivers with OSA. The simplest and most effective objective strategies use body mass index (BMI) cutoffs for obesity. Functional screens are promising adjuncts to other objective tests. The most effective approach will likely be a combination of a good questionnaire; BMI measures; and a careful physician-obtained history complemented by a functional screen.

  9. Optimization of three- and four-component reactions for polysubstituted piperidines: application to the synthesis and preliminary biological screening of a prototype library.

    PubMed

    Ulaczyk-Lesanko, Agnieszka; Pelletier, Eric; Lee, Maria; Prinz, Heino; Waldmann, Herbert; Hall, Dennis G

    2007-01-01

    Several solid- and solution-phase strategies were evaluated for the preparation of libraries of polysubstituted piperidines of type 7 using the tandem aza[4+2]cycloaddition/allylboration multicomponent reaction between 1-aza-4-boronobutadienes, maleimides, and aldehydes. A novel four-component variant of this chemistry was developed in solution phase, and it circumvents the need for pre-forming the azabutadiene component. A parallel synthesis coupled with compound purification by HPLC with mass-based fraction collection allowed the preparation of a library of 944 polysubstituted piperidines in a high degree of purity suitable for biological screening. A representative subset of 244 compounds was screened against a panel of phosphatase enzymes, and despite the modest levels of activity obtained, this study demonstrated that piperidines of type 7 display the right physical properties (e.g., solubility) to be assayed effectively in high-throughput enzymatic tests.

  10. Could CT screening for lung cancer ever be cost effective in the United Kingdom?

    PubMed Central

    Whynes, David K

    2008-01-01

    Background The absence of trial evidence makes it impossible to determine whether or not mass screening for lung cancer would be cost effective and, indeed, whether a clinical trial to investigate the problem would be justified. Attempts have been made to resolve this issue by modelling, although the complex models developed to date have required more real-world data than are currently available. Being founded on unsubstantiated assumptions, they have produced estimates with wide confidence intervals and of uncertain relevance to the United Kingdom. Method I develop a simple, deterministic, model of a screening regimen potentially applicable to the UK. The model includes only a limited number of parameters, for the majority of which, values have already been established in non-trial settings. The component costs of screening are derived from government guidance and from published audits, whilst the values for test parameters are derived from clinical studies. The expected health gains as a result of screening are calculated by combining published survival data for screened and unscreened cohorts with data from Life Tables. When a degree of uncertainty over a parameter value exists, I use a conservative estimate, i.e. one likely to make screening appear less, rather than more, cost effective. Results The incremental cost effectiveness ratio of a single screen amongst a high-risk male population is calculated to be around £14,000 per quality-adjusted life year gained. The average cost of this screening regimen per person screened is around £200. It is possible that, when obtained experimentally in any future trial, parameter values will be found to differ from those previously obtained in non-trial settings. On the basis both of differing assumptions about evaluation conventions and of reasoned speculations as to how test parameters and costs might behave under screening, the model generates cost effectiveness ratios as high as around £20,000 and as low as around £7,000. Conclusion It is evident that eventually being able to identify a cost effective regimen of CT screening for lung cancer in the UK is by no means an unreasonable expectation. PMID:18302756

  11. Development and Validation of a Qualitative Method for Target Screening of 448 Pesticide Residues in Fruits and Vegetables Using UHPLC/ESI Q-Orbitrap Based on Data-Independent Acquisition and Compound Database.

    PubMed

    Wang, Jian; Chow, Willis; Chang, James; Wong, Jon W

    2017-01-18

    A semiautomated qualitative method for target screening of 448 pesticide residues in fruits and vegetables was developed and validated using ultrahigh-performance liquid chromatography coupled with electrospray ionization quadrupole Orbitrap high-resolution mass spectrometry (UHPLC/ESI Q-Orbitrap). The Q-Orbitrap Full MS/dd-MS 2 (data dependent acquisition) was used to acquire product-ion spectra of individual pesticides to build a compound database or an MS library, while its Full MS/DIA (data independent acquisition) was utilized for sample data acquisition from fruit and vegetable matrices fortified with pesticides at 10 and 100 μg/kg for target screening purpose. Accurate mass, retention time and response threshold were three key parameters in a compound database that were used to detect incurred pesticide residues in samples. The concepts and practical aspects of in-spectrum mass correction or solvent background lock-mass correction, retention time alignment and response threshold adjustment are discussed while building a functional and working compound database for target screening. The validated target screening method is capable of screening at least 94% and 99% of 448 pesticides at 10 and 100 μg/kg, respectively, in fruits and vegetables without having to evaluate every compound manually during data processing, which significantly reduced the workload in routine practice.

  12. Simultaneous detection and classification of breast masses in digital mammograms via a deep learning YOLO-based CAD system.

    PubMed

    Al-Masni, Mohammed A; Al-Antari, Mugahed A; Park, Jeong-Min; Gi, Geon; Kim, Tae-Yeon; Rivera, Patricio; Valarezo, Edwin; Choi, Mun-Taek; Han, Seung-Moo; Kim, Tae-Seong

    2018-04-01

    Automatic detection and classification of the masses in mammograms are still a big challenge and play a crucial role to assist radiologists for accurate diagnosis. In this paper, we propose a novel Computer-Aided Diagnosis (CAD) system based on one of the regional deep learning techniques, a ROI-based Convolutional Neural Network (CNN) which is called You Only Look Once (YOLO). Although most previous studies only deal with classification of masses, our proposed YOLO-based CAD system can handle detection and classification simultaneously in one framework. The proposed CAD system contains four main stages: preprocessing of mammograms, feature extraction utilizing deep convolutional networks, mass detection with confidence, and finally mass classification using Fully Connected Neural Networks (FC-NNs). In this study, we utilized original 600 mammograms from Digital Database for Screening Mammography (DDSM) and their augmented mammograms of 2,400 with the information of the masses and their types in training and testing our CAD. The trained YOLO-based CAD system detects the masses and then classifies their types into benign or malignant. Our results with five-fold cross validation tests show that the proposed CAD system detects the mass location with an overall accuracy of 99.7%. The system also distinguishes between benign and malignant lesions with an overall accuracy of 97%. Our proposed system even works on some challenging breast cancer cases where the masses exist over the pectoral muscles or dense regions. Copyright © 2018 Elsevier B.V. All rights reserved.

  13. Screening and identification of glyceollins and their metabolites by electrospray ionization tandem mass spectrometry with precursor ion scanning

    USDA-ARS?s Scientific Manuscript database

    A method has been developed for screening glyceollins and their metabolites based upon precursor ion scanning. Under higher-energy collision conditions, employing a triple quadrupole mass spectrometer in the negative ion mode, deprotonated glyceollin precursors yield a diagnostic radical product ion...

  14. The diagnostic accuracy of exercise electrocardiography - A review

    NASA Technical Reports Server (NTRS)

    Johnson, R. L.; Bungo, M. W.

    1983-01-01

    The cardiovascular 'stress test', and particularly the graded treadmill exercist test, has gained wide acceptance as a diagnostic aid in searching for ischemic heart disease and as a prognostic indicator for those with known coronary artery disease. Controversies still exist, however, in its use in mass screening and in interpreting equivocal tests. A review of the use and value of electrocardiographic exercise testing is presented. Topics such as its use in asymptomatic individuals, the adjuvant use of clinical examination, and the examination of ancillary treadmill parameters are presented. No attempt is made to detail the very significant contributions of radionuclide scanning. The positive exercise electrocardiogram in the asymptomatic subject is discussed and guidelines for clinical management are offered.

  15. Analyzing Screening Policies for Childhood Obesity

    PubMed Central

    Yang, Yan; Goldhaber-Fiebert, Jeremy D.; Wein, Lawrence M.

    2013-01-01

    Due to the health and economic costs of childhood obesity, coupled with studies suggesting the benefits of comprehensive (dietary, physical activity and behavioral counseling) intervention, the United States Preventive Services Task Force recently recommended childhood screening and intervention for obesity beginning at age six. Using a longitudinal data set consisting of the body mass index of 3164 children up to age 18 and another longitudinal data set containing the body mass index at ages 18 and 40 and the presence or absence of disease (hypertension and diabetes) at age 40 for 747 people, we formulate and numerically solve – separately for boys and girls – a dynamic programming problem for the optimal biennial (i.e., at ages 2, 4, …, 16) obesity screening thresholds. Unlike most screening problem formulations, we take a societal viewpoint, where the state of the system at each age is the population-wide probability density function of the body mass index. Compared to the biennial version of the task force’s recommendation, the screening thresholds derived from the dynamic program achieve a relative reduction in disease prevalence of 3% at the same screening (and treatment) cost, or – due to the flatness of the disease vs. screening tradeoff curve – achieves the same disease prevalence at a 28% relative reduction in cost. Compared to the task force’s policy, which uses the 95th percentile of body mass index (from cross-sectional growth charts tabulated by the Centers for Disease Control and Prevention) as the screening threshold for each age, the dynamic programming policy treats mostly 16 year olds (including many who are not obese) and very few males under 14 years old. While our results suggest that adult hypertension and diabetes are minimized by focusing childhood obesity screening and treatment on older adolescents, the shortcomings in the available data and the narrowness of the medical outcomes considered prevent us from making a recommendation about childhood obesity screening policies. PMID:23956465

  16. Pion quasiparticle in the low-temperature phase of QCD

    NASA Astrophysics Data System (ADS)

    Brandt, Bastian B.; Francis, Anthony; Meyer, Harvey B.; Robaina, Daniel

    2015-11-01

    We investigate the properties of the pion quasiparticle in the low-temperature phase of two-flavor QCD on the lattice with support from chiral effective theory. We find that the pion quasiparticle mass is significantly reduced compared to its value in the vacuum, in contrast with the static screening mass, which increases with temperature. By a simple argument, near the chiral limit the two masses are expected to determine the quasiparticle dispersion relation. Analyzing two-point functions of the axial charge density at nonvanishing spatial momentum, we find that the predicted dispersion relation and the residue of the pion pole are consistent with the lattice data at low momentum. This test, based on fits to the correlation functions, is confirmed by a second analysis using the Backus-Gilbert method.

  17. Supplement to MTI study on selective passenger screening in the mass transit rail environment.

    DOT National Transportation Integrated Search

    2010-01-01

    This supplement updates and adds to MTIs 2007 report on Selective Screening of Rail Passengers (Jenkins and Butterworth MTI 06-07: Selective Screening of Rail Passengers). The report reviews current screening programs implemented (or planned) by n...

  18. Rapid detection and differentiation of avian infectious bronchitis virus: an application of Mass genotype by melting temperature analysis in RT-qPCR using SYBR Green I

    PubMed Central

    OKINO, Cintia Hiromi; MONTASSIER, Maria de Fátima Silva; de OLIVEIRA, Andressa Peres; MONTASSIER, Helio José

    2018-01-01

    A method based on Melting Temperature analysis of Hypervariable regions (HVR) of S1 gene within a RT-qPCR was developed to detect different genotypes of avian infectious bronchitis virus (IBV) and identify the Mass genotype. The method was able to rapidly identify the Mass genotype among IBV field isolates, vaccine attenuated strains and reference M41 strain in allantoic liquid and also directly in tissues. The RT-qPCR developed detected the virus in both tracheal and pulmonary samples from M41-infected or H120-infected birds, in a larger post-infection period compared to detection by standard method of virus isolation. RT-qPCR method tested provided a sensitivity and rapid approach for screening on IBV detection and Mass genotyping from IBV isolates. PMID:29491226

  19. Development of a comprehensive screening method for more than 300 organic chemicals in water samples using a combination of solid-phase extraction and liquid chromatography-time-of-flight-mass spectrometry.

    PubMed

    Chau, Hong Thi Cam; Kadokami, Kiwao; Ifuku, Tomomi; Yoshida, Yusuke

    2017-12-01

    A comprehensive screening method for 311 organic compounds with a wide range of physicochemical properties (log Pow -2.2-8.53) in water samples was developed by combining solid-phase extraction with liquid chromatography-high-resolution time-of-flight mass spectrometry. Method optimization using 128 pesticides revealed that tandem extraction with styrene-divinylbenzene polymer and activated carbon solid-phase extraction cartridges at pH 7.0 was optimal. The developed screening method was able to extract 190 model compounds with average recovery of 80.8% and average relative standard deviations (RSD) of 13.5% from spiked reagent water at 0.20 μg L -1 , and 87.1% recovery and 10.8% RSD at 0.05 μg L -1 . Spike-recovery testing (0.20 μg L -1 ) using real sewage treatment plant effluents resulted in an average recovery and average RSD of 190 model compounds of 77.4 and 13.1%, respectively. The method was applied to the influent and effluent of five sewage treatment plants in Kitakyushu, Japan, with 29 out of 311 analytes being observed at least once. The results showed that this method can screen for a large number of chemicals with a wide range of physicochemical properties quickly and at low operational cost, something that is difficult to achieve using conventional analytical methods. This method will find utility in target screening of hazardous chemicals with a high risk in environmental waters, and for confirming the safety of water after environmental incidents.

  20. The Sweat Metabolome of Screen-Positive Cystic Fibrosis Infants: Revealing Mechanisms beyond Impaired Chloride Transport

    PubMed Central

    2017-01-01

    The sweat chloride test remains the gold standard for confirmatory diagnosis of cystic fibrosis (CF) in support of universal newborn screening programs. However, it provides ambiguous results for intermediate sweat chloride cases while not reflecting disease progression when classifying the complex CF disease spectrum given the pleiotropic effects of gene modifiers and environment. Herein we report the first characterization of the sweat metabolome from screen-positive CF infants and identify metabolites associated with disease status that complement sweat chloride testing. Pilocarpine-stimulated sweat specimens were collected independently from two CF clinics, including 50 unaffected infants (e.g., carriers) and 18 confirmed CF cases. Nontargeted metabolite profiling was performed using multisegment injection–capillary electrophoresis–mass spectrometry as a high throughput platform for analysis of polar/ionic metabolites in volume-restricted sweat samples. Amino acids, organic acids, amino acid derivatives, dipeptides, purine derivatives, and unknown exogenous compounds were identified in sweat when using high resolution tandem mass spectrometry, including metabolites associated with affected yet asymptomatic CF infants, such as asparagine and glutamine. Unexpectedly, a metabolite of pilocarpine, used to stimulate sweat secretion, pilocarpic acid, and a plasticizer metabolite from environmental exposure, mono(2-ethylhexyl)phthalic acid, were secreted in the sweat of CF infants at significantly lower concentrations relative to unaffected CF screen-positive controls. These results indicated a deficiency in human paraoxonase, an enzyme unrelated to mutations to the cystic fibrosis transmembrane conductance regulator (CFTR) and impaired chloride transport, which is a nonspecific arylesterase/lactonase known to mediate inflammation, bacterial biofilm formation, and recurrent lung infections in affected CF children later in life. This work sheds new light into the underlying mechanisms of CF pathophysiology as required for new advances in precision medicine of orphan diseases that benefit from early detection and intervention, including new molecular targets for therapeutic intervention. PMID:28852705

  1. The Sweat Metabolome of Screen-Positive Cystic Fibrosis Infants: Revealing Mechanisms beyond Impaired Chloride Transport.

    PubMed

    Macedo, Adriana N; Mathiaparanam, Stellena; Brick, Lauren; Keenan, Katherine; Gonska, Tanja; Pedder, Linda; Hill, Stephen; Britz-McKibbin, Philip

    2017-08-23

    The sweat chloride test remains the gold standard for confirmatory diagnosis of cystic fibrosis (CF) in support of universal newborn screening programs. However, it provides ambiguous results for intermediate sweat chloride cases while not reflecting disease progression when classifying the complex CF disease spectrum given the pleiotropic effects of gene modifiers and environment. Herein we report the first characterization of the sweat metabolome from screen-positive CF infants and identify metabolites associated with disease status that complement sweat chloride testing. Pilocarpine-stimulated sweat specimens were collected independently from two CF clinics, including 50 unaffected infants (e.g., carriers) and 18 confirmed CF cases. Nontargeted metabolite profiling was performed using multisegment injection-capillary electrophoresis-mass spectrometry as a high throughput platform for analysis of polar/ionic metabolites in volume-restricted sweat samples. Amino acids, organic acids, amino acid derivatives, dipeptides, purine derivatives, and unknown exogenous compounds were identified in sweat when using high resolution tandem mass spectrometry, including metabolites associated with affected yet asymptomatic CF infants, such as asparagine and glutamine. Unexpectedly, a metabolite of pilocarpine, used to stimulate sweat secretion, pilocarpic acid, and a plasticizer metabolite from environmental exposure, mono(2-ethylhexyl)phthalic acid, were secreted in the sweat of CF infants at significantly lower concentrations relative to unaffected CF screen-positive controls. These results indicated a deficiency in human paraoxonase, an enzyme unrelated to mutations to the cystic fibrosis transmembrane conductance regulator (CFTR) and impaired chloride transport, which is a nonspecific arylesterase/lactonase known to mediate inflammation, bacterial biofilm formation, and recurrent lung infections in affected CF children later in life. This work sheds new light into the underlying mechanisms of CF pathophysiology as required for new advances in precision medicine of orphan diseases that benefit from early detection and intervention, including new molecular targets for therapeutic intervention.

  2. Sedentary Screen Time and Left Ventricular Structure and Function: the CARDIA Study

    PubMed Central

    Gibbs, Bethany Barone; Reis, Jared P.; Schelbert, Erik B.; Craft, Lynette L.; Sidney, Steve; Lima, Joao; Lewis, Cora E.

    2013-01-01

    Sedentary screen time (watching TV or using a computer) predicts cardiovascular outcomes independently from moderate and vigorous physical activity and could impact left ventricular structure and function through the adverse consequences of sedentary behavior. Purpose To determine whether sedentary screen time is associated with measures of left ventricular structure and function. Methods The Coronary Artery Risk Development in Young Adults (CARDIA) Study measured screen time by questionnaire and left ventricular structure and function by echocardiography in 2,854 black and white participants, aged 43–55 years, in 2010–2011. Generalized linear models evaluated cross-sectional trends for echocardiography measures across higher categories of screen time and adjusting for demographics, smoking, alcohol, and physical activity. Further models adjusted for potential intermediate factors (blood pressure, antihypertensive medication use, diabetes, and body mass index (BMI). Results The relationship between screen time and left ventricular mass(LVM) differed in blacks vs. whites. Among whites, higher screen time was associated with larger LVM (P<0.001), after adjustment for height, demographics, and lifestyle variables. Associations between screen time and LVM persisted when adjusting for blood pressure, antihypertensive medication use, and diabetes (P=0.008) but not with additional adjustment for BMI (P=0.503). Similar relationships were observed for screen time with LVM indexed to height2.7, relative wall thickness, and mass-to-volume ratio. Screen time was not associated with left ventricular structure among blacks or left ventricular function in either race group. Conclusions Sedentary screen time is associated with greater LVM in white adults and this relationship was largely explained by higher overall adiposity. The lack of association in blacks supports a potential qualitative difference in the cardiovascular consequences of sedentary screen-based behavior. PMID:23863618

  3. Fast analysis of doping agents in urine by ultra-high-pressure liquid chromatography-quadrupole time-of-flight mass spectrometry I. Screening analysis.

    PubMed

    Badoud, F; Grata, E; Perrenoud, L; Avois, L; Saugy, M; Rudaz, S; Veuthey, J-L

    2009-05-15

    The general strategy to perform anti-doping analyses of urine samples starts with the screening for a wide range of compounds. This step should be fast, generic and able to detect any sample that may contain a prohibited substance while avoiding false negatives and reducing false positive results. The experiments presented in this work were based on ultra-high-pressure liquid chromatography coupled to hybrid quadrupole time-of-flight mass spectrometry. Thanks to the high sensitivity of the method, urine samples could be diluted 2-fold prior to injection. One hundred and three forbidden substances from various classes (such as stimulants, diuretics, narcotics, anti-estrogens) were analysed on a C(18) reversed-phase column in two gradients of 9min (including two 3min equilibration periods) for positive and negative electrospray ionisation and detected in the MS full scan mode. The automatic identification of analytes was based on retention time and mass accuracy, with an automated tool for peak picking. The method was validated according to the International Standard for Laboratories described in the World Anti-Doping Code and was selective enough to comply with the World Anti-Doping Agency recommendations. In addition, the matrix effect on MS response was measured on all investigated analytes spiked in urine samples. The limits of detection ranged from 1 to 500ng/mL, allowing the identification of all tested compounds in urine. When a sample was reported positive during the screening, a fast additional pre-confirmatory step was performed to reduce the number of confirmatory analyses.

  4. Screening and confirmation of steroids and nitroimidazoles in urine, blood, and food matrices: Sample preparation methods and liquid chromatography tandem mass spectrometric separations.

    PubMed

    Tölgyesi, Ádám; Barta, Enikő; Simon, Andrea; McDonald, Thomas J; Sharma, Virender K

    2017-10-25

    Veterinary drugs containing synthetic anabolic steroid and nitroimidazole active agents are not allowed for their applications in livestock of the European Union (EU). This paper presents analyses of twelve selected steroids and six nitroimidazole antibiotics at low levels (1.56μg/L-4.95μg/L and 0.17μg/kg-2.14μg/kg, respectively) in body fluids and egg incurred samples. Analyses involved clean-up procedures, high performance liquid chromatography (HPLC) separation, and tandem mass spectrometric screening and confirmatory methods. Target steroids and nitroimidazoles in samples were cleaned by two independent supported liquid extraction and solid phase extraction procedures. Separation of the selected compounds was conducted on Kinetex XB C-18 HPLC column using gradient elution. The screening methods utilised supported liquid extraction that enabled fast and cost effective clean-up. The confirmatory methods were improved by extending the number of matrices and compounds, and by introducing an isotope dilution mass spectrometry for nitroimidazoles. The new methods were validated according to the recommendation of the European Union Reference Laboratories and the performance characteristics evaluated met fully the criteria. The methods were applied to incurred samples in the proficiency tests. The obtained results of Z-scores demonstrated the applicability of developed protocols of the methods to real samples. The confirmatory methods were applied to the national monitoring program and natural contamination of prednisolone could be detected in urine at low concentration in few samples. Copyright © 2017 Elsevier B.V. All rights reserved.

  5. Fast mass spectrometry-based enantiomeric excess determination of proteinogenic amino acids.

    PubMed

    Fleischer, Heidi; Thurow, Kerstin

    2013-03-01

    A rapid determination of the enantiomeric excess of proteinogenic amino acids is of great importance in various fields of chemical and biologic research and industries. Owing to their different biologic effects, enantiomers are interesting research subjects in drug development for the design of new and more efficient pharmaceuticals. Usually, the enantiomeric composition of amino acids is determined by conventional analytical methods such as liquid or gas chromatography or capillary electrophoresis. These analytical techniques do not fulfill the requirements of high-throughput screening due to their relative long analysis times. The method presented allows a fast analysis of chiral amino acids without previous time consuming chromatographic separation. The analytical measurements base on parallel kinetic resolution with pseudoenantiomeric mass tagged auxiliaries and were carried out by mass spectrometry with electrospray ionization. All 19 chiral proteinogenic amino acids were tested and Pro, Ser, Trp, His, and Glu were selected as model substrates for verification measurements. The enantiomeric excesses of amino acids with non-polar and aliphatic side chains as well as Trp and Phe (aromatic side chains) were determined with maximum deviations of the expected value less than or equal to 10ee%. Ser, Cys, His, Glu, and Asp were determined with deviations lower or equal to 14ee% and the enantiomeric excess of Tyr were calculated with 17ee% deviation. The total screening process is fully automated from the sample pretreatment to the data processing. The method presented enables fast measurement times about 1.38 min per sample and is applicable in the scope of high-throughput screenings.

  6. Assertions of Japanese Websites for and Against Cancer Screening: a Text Mining Analysis

    PubMed

    Okuhara, Tsuyoshi; Ishikawa, Hirono; Okada, Masahumi; Kato, Mio; Kiuchi, Takahiro

    2017-04-01

    Background: Cancer screening rates are lower in Japan than in Western countries such as the United States and the United Kingdom. While health professionals publish pro-cancer-screening messages online to encourage proactive seeking for screening, anti-screening activists use the same medium to warn readers against following guidelines. Contents of pro- and anti-cancer-screening sites may contribute to readers’ acceptance of one or the other position. We aimed to use a text-mining method to examine frequently appearing contents on sites for and against cancer screening. Methods: We conducted online searches in December 2016 using two major search engines in Japan (Google Japan and Yahoo! Japan). Targeted websites were classified as “pro”, “anti”, or “neutral” depending on their claims, with the author(s) classified as “health professional”, “mass media”, or “layperson”. Text-mining analyses were conducted, and statistical analysis was performed using the chi-square test. Results: Of the 169 websites analyzed, the top-three most frequently appearing content topics in pro sites were reducing mortality via cancer screening, benefits of early detection, and recommendations for obtaining detailed examination. The top three most frequent in anti-sites were harm from radiation exposure, non-efficacy of cancer screening, and lack of necessity of early detection. Anti-sites also frequently referred to a well-known Japanese radiologist, Makoto Kondo, who rejects the standard forms of cancer care. Conclusion: Our findings should enable authors of pro-cancer-screening sites to write to counter misleading anti-cancer-screening messages and facilitate dissemination of accurate information. Creative Commons Attribution License

  7. Comparison of a new digital KM screen test with conventional Hess and Lees screen tests in the mapping of ocular deviations.

    PubMed

    Thorisdottir, Rannveig Linda; Sundgren, Johanna; Sheikh, Rafi; Blohmé, Jonas; Hammar, Björn; Kjellström, Sten; Malmsjö, Malin

    2018-05-28

    To evaluate the digital KM screen computerized ocular motility test and to compare it with conventional nondigital techniques using the Hess and Lees screens. Patients with known ocular deviations and a visual acuity of at least 20/100 underwent testing using the digital KM screen and the Hess and Lees screen tests. The examination duration, the subjectively perceived difficulty, and the patient's method of choice were compared for the three tests. The accuracy of test results was compared using Bland-Altman plots between testing methods. A total of 19 patients were included. Examination with the digital KM screen test was less time-consuming than tests with the Hess and Lees screens (P < 0.001 and P = 0.003, resp., compared with the digital KM screen). Patients found the test with the digital KM screen easier to perform than the Lees screen test (P = 0.009) but of similar difficulty to the Hess screen test (P = 0.203). The majority of the patients (83%) preferred the digital KM screen test to both of the other screen methods (P = 0.008). Bland-Altman plots showed that the results obtained with all three tests were similar. The digital KM screen is accurate and time saving and provides similar results to Lees and Hess screen testing. It also has the advantage of a digital data analysis and registration. Copyright © 2018 American Association for Pediatric Ophthalmology and Strabismus. Published by Elsevier Inc. All rights reserved.

  8. Delayed bedtime due to screen time in schoolchildren: importance of area deprivation.

    PubMed

    Ogunleye, Ayodele A; Voss, Christine; Sandercock, Gavin R

    2015-01-01

    Sleep duration is an important predictor of obesity and health. This study evaluated the association between late bedtime and screen time, and the role of geographical deprivation in English schoolchildren. We collected bedtime and waking time, screen time, sociodemographic data and measured body mass index in a cross-section of 1332 11-15-year-old schoolchildren (45.7% female) participating in the East of England healthy heart study. Logistic regression was used to determine the likelihood of late bedtime in schoolchildren with different screen time and from a different geographic location. Mean differences were assessed either on ANOVA or t-test. Approximately 42% of boys went to bed late at night compared with 37% of girls. When compared to those with <2 h of daily screen time, schoolchildren with 2-4 h of screen time were more likely [odds ratio (OR) = 1.50, 95% confidence interval (CI): 1.07-2.09] to go to bed late at night while those with >4 h of daily screen time were most likely to go to sleep late at night (OR, 1.97; 95%CI: 1.34-2.89). Late bedtime was associated with deprivation in schoolchildren. High screen time and deprivation may explain lateness in bedtime in English schoolchildren. This explanation may vary according to area deprivation and geographic location. Family-centered interventions and parental support are important to reduce screen time, late bedtime and increase sleep duration. © 2014 Japan Pediatric Society.

  9. Newborn bloodspot screening in the UK--past, present and future.

    PubMed

    Downing, Melanie; Pollitt, Rodney

    2008-01-01

    Screening newborn babies for inherited metabolic disease began in the UK in the late 1950s with the 'nappy test' for phenylketonuria. In 1969 the Department of Health recommended changing to bloodspot screening using the techniques developed in the USA by Robert Guthrie and his associates. Bloodspot screening for various other disorders (galactosaemia, maple syrup urine disease, homocystinuria, cystic fibrosis and others) was introduced on a patchy local basis but, until 2000, the only additional disorder officially recommended was congenital hypothyroidism. Screening for haemoglobinopathies received official support in 2000 and for cystic fibrosis in 2001 though implementation was slow, particularly for the latter. Both these screens have raised difficult issues relating to genetic privacy and the detection of carrier status in children. During the last decade screening has become increasingly subject to central control. Though a more consistent and systematic approach was clearly needed, this has undoubtedly slowed the rate of innovation. In particular the UK has lagged behind many other European countries in the application of tandem mass spectrometry (MS-MS) though, following a major pilot study, screening for medium-chain acyl-CoA dehydrogenase deficiency is now in the process of introduction. Attempts to codify clinical and laboratory procedures have also proved controversial, highlighting marked differences in practice in various parts of the country and the difficulty of rationalizing these within a practicable and scientifically justified framework. Notwithstanding this, there are many positive developments and newborn screening remains a stimulating and rewarding field in which to work.

  10. Mass spectrometric screening of ligands with lower off-rate from a clicked-based pooled library.

    PubMed

    Arai, Satoshi; Hirosawa, Shota; Oguchi, Yusuke; Suzuki, Madoka; Murata, Atsushi; Ishiwata, Shin'ichi; Takeoka, Shinji

    2012-08-13

    This paper describes a convenient screening method using ion trap electrospray ionization mass spectrometry to classify ligands to a target molecule in terms of kinetic parameters. We demonstrate this method in the screening of ligands to a hexahistidine tag from a pooled library synthesized by click chemistry. The ion trap mass spectrometry analysis revealed that higher stabilities of ligand-target complexes in the gas phase were related to lower dissociation rate constants, i.e., off-rates in solution. Finally, we prepared a fluorescent probe utilizing the ligand with lowest off-rate and succeeded in performing single molecule observations of hexahistidine-tagged myosin V walking on actin filaments.

  11. Multi-task transfer learning deep convolutional neural network: application to computer-aided diagnosis of breast cancer on mammograms

    NASA Astrophysics Data System (ADS)

    Samala, Ravi K.; Chan, Heang-Ping; Hadjiiski, Lubomir M.; Helvie, Mark A.; Cha, Kenny H.; Richter, Caleb D.

    2017-12-01

    Transfer learning in deep convolutional neural networks (DCNNs) is an important step in its application to medical imaging tasks. We propose a multi-task transfer learning DCNN with the aim of translating the ‘knowledge’ learned from non-medical images to medical diagnostic tasks through supervised training and increasing the generalization capabilities of DCNNs by simultaneously learning auxiliary tasks. We studied this approach in an important application: classification of malignant and benign breast masses. With Institutional Review Board (IRB) approval, digitized screen-film mammograms (SFMs) and digital mammograms (DMs) were collected from our patient files and additional SFMs were obtained from the Digital Database for Screening Mammography. The data set consisted of 2242 views with 2454 masses (1057 malignant, 1397 benign). In single-task transfer learning, the DCNN was trained and tested on SFMs. In multi-task transfer learning, SFMs and DMs were used to train the DCNN, which was then tested on SFMs. N-fold cross-validation with the training set was used for training and parameter optimization. On the independent test set, the multi-task transfer learning DCNN was found to have significantly (p  =  0.007) higher performance compared to the single-task transfer learning DCNN. This study demonstrates that multi-task transfer learning may be an effective approach for training DCNN in medical imaging applications when training samples from a single modality are limited.

  12. Automatic detection of anomalies in screening mammograms

    PubMed Central

    2013-01-01

    Background Diagnostic performance in breast screening programs may be influenced by the prior probability of disease. Since breast cancer incidence is roughly half a percent in the general population there is a large probability that the screening exam will be normal. That factor may contribute to false negatives. Screening programs typically exhibit about 83% sensitivity and 91% specificity. This investigation was undertaken to determine if a system could be developed to pre-sort screening-images into normal and suspicious bins based on their likelihood to contain disease. Wavelets were investigated as a method to parse the image data, potentially removing confounding information. The development of a classification system based on features extracted from wavelet transformed mammograms is reported. Methods In the multi-step procedure images were processed using 2D discrete wavelet transforms to create a set of maps at different size scales. Next, statistical features were computed from each map, and a subset of these features was the input for a concerted-effort set of naïve Bayesian classifiers. The classifier network was constructed to calculate the probability that the parent mammography image contained an abnormality. The abnormalities were not identified, nor were they regionalized. The algorithm was tested on two publicly available databases: the Digital Database for Screening Mammography (DDSM) and the Mammographic Images Analysis Society’s database (MIAS). These databases contain radiologist-verified images and feature common abnormalities including: spiculations, masses, geometric deformations and fibroid tissues. Results The classifier-network designs tested achieved sensitivities and specificities sufficient to be potentially useful in a clinical setting. This first series of tests identified networks with 100% sensitivity and up to 79% specificity for abnormalities. This performance significantly exceeds the mean sensitivity reported in literature for the unaided human expert. Conclusions Classifiers based on wavelet-derived features proved to be highly sensitive to a range of pathologies, as a result Type II errors were nearly eliminated. Pre-sorting the images changed the prior probability in the sorted database from 37% to 74%. PMID:24330643

  13. Colon cancer screening

    MedlinePlus

    Screening for colon cancer; Colonoscopy - screening; Sigmoidoscopy - screening; Virtual colonoscopy - screening; Fecal immunochemical test; Stool DNA test; sDNA test; Colorectal cancer - screening; Rectal ...

  14. Multifactorial Analysis of Mortality in Screening Detected Lung Cancer.

    PubMed

    Digumarthy, Subba R; De Man, Ruben; Canellas, Rodrigo; Otrakji, Alexi; Wang, Ge; Kalra, Mannudeep K

    2018-01-01

    We hypothesized that severity of coronary artery calcification (CAC), emphysema, muscle mass, and fat attenuation can help predict mortality in patients with lung cancer participating in the National Lung Screening Trial (NLST). Following regulatory approval from the Cancer Data Access System (CDAS), all patients diagnosed with lung cancer at the time of the screening study were identified. These subjects were classified into two groups: survivors and nonsurvivors at the conclusion of the NLST trial. These groups were matched based on their age, gender, body mass index (BMI), smoking history, lung cancer stage, and survival time. CAC, emphysema, muscle mass, and subcutaneous fat attenuation were quantified on baseline low-dose chest CT (LDCT) for all patients in both groups. Nonsurvivor group had significantly greater CAC, decreased muscle mass, and higher fat attenuation compared to the survivor group ( p < 0.01). No significant difference in severity of emphysema was noted between the two groups ( p > 0.1). We thus conclude that it is possible to create a quantitative prediction model for lung cancer mortality for subjects with lung cancer detected on screening low-dose CT (LDCT).

  15. Radiologic findings of screen-detected cancers in an organized population-based screening mammography program in Turkey

    PubMed Central

    Kayhan, Arda; Arıbal, Erkin; Şahin, Cennet; Taşçı, Ömür Can; Gürdal, Sibel Özkan; Öztürk, Enis; Hatipoğlu, Hayat Halide; Özaydın, Nilüfer; Cabioğlu, Neslihan; Özçınar, Beyza; Özmen, Vahit

    2016-01-01

    PURPOSE Bahçeşehir Breast Cancer Screening Program is a population based organized screening program in Turkey, where asymptomatic women aged 40–69 years are screened biannually. In this prospective study, we aimed to determine the mammographic findings of screen-detected cancers and discuss the efficacy of breast cancer screening in a developing country. METHODS A total of 6912 women were screened in three rounds. The radiologic findings were grouped as mass, focal asymmetry, calcification, and architectural distortion. Masses were classified according to shape, border, and density. Calcifications were grouped according to morphology and distribution. Cancers were grouped according to the clinical stage. RESULTS Seventy cancers were detected with an incidence of 4.8/1000. Two cancers were detected in other centers and three were not visualized mammographically. Mammographic presentations of the remaining 65 cancers were mass (47.7%, n=31), calcification (30.8%, n=20), focal asymmetry (16.9%, n=11), architectural distortion (3.1%, n=2), and skin thickening (1.5%, n=1). The numbers of stage 0, 1, 2, 3, and 4 cancers were 13 (20.0%), 34 (52.3%), 14 (21.5%), 3 (4.6%), and 1 (1.5%), respectively. The numbers of interval and missed cancers were 5 (7.4%) and 7 (10.3%), respectively. CONCLUSION A high incidence of early breast cancer has been detected. The incidence of missed and interval cancers did not show major differences from western screening trials. We believe that this study will pioneer implementation of efficient population-based mammographic screenings in developing countries. PMID:27705880

  16. Development of a Clinical Forecasting Model to Predict Comorbid Depression Among Diabetes Patients and an Application in Depression Screening Policy Making.

    PubMed

    Jin, Haomiao; Wu, Shinyi; Di Capua, Paul

    2015-09-03

    Depression is a common but often undiagnosed comorbid condition of people with diabetes. Mass screening can detect undiagnosed depression but may require significant resources and time. The objectives of this study were 1) to develop a clinical forecasting model that predicts comorbid depression among patients with diabetes and 2) to evaluate a model-based screening policy that saves resources and time by screening only patients considered as depressed by the clinical forecasting model. We trained and validated 4 machine learning models by using data from 2 safety-net clinical trials; we chose the one with the best overall predictive ability as the ultimate model. We compared model-based policy with alternative policies, including mass screening and partial screening, on the basis of depression history or diabetes severity. Logistic regression had the best overall predictive ability of the 4 models evaluated and was chosen as the ultimate forecasting model. Compared with mass screening, the model-based policy can save approximately 50% to 60% of provider resources and time but will miss identifying about 30% of patients with depression. Partial-screening policy based on depression history alone found only a low rate of depression. Two other heuristic-based partial screening policies identified depression at rates similar to those of the model-based policy but cost more in resources and time. The depression prediction model developed in this study has compelling predictive ability. By adopting the model-based depression screening policy, health care providers can use their resources and time better and increase their efficiency in managing their patients with depression.

  17. Estimated Cost of Crashes in Commercial Drivers Supports Screening and Treatment of Obstructive Sleep Apnea

    PubMed Central

    Gurubhagavatula, Indira; Nkwuo, Jonathan E.; Maislin, Greg; Pack, Allan I.

    2009-01-01

    Sleep apnea among commercial drivers may increase the risk of fall-asleep crashes, which incur large expenses. Drivers of passenger cars whose apnea is treated experience lower crash risk. Among community-based holders of commercial driver’s licenses, we considered three methods for identifying sleep apnea syndrome: 1) in-lab polysomnography; 2) selective in-lab polysomnography for high-risk drivers, where high risk is first identified by body mass index, age and gender, followed by oximetry in a subset of drivers; and 3) not screening. The costs for each of these three programs equaled the sum of the costs of testing, treatment of identified cases, and crashes. Assuming that treatment prevents apnea-related crashes, polysomnography is not cost-effective, because it was more expensive than the cost of crashes when no screening is done. Screening with BMI, age and gender, however, with confirmatory in-lab polysomnography only on high-risk drivers was cost-effective, as long as a high proportion (73.8%) of screened drivers accepts treatment. These findings indicate that strategies that reduce reliance on in-laboratory polysomnography may be more cost-effective than not screening, and that treatment acceptance may need to be a condition of employment for affected drivers. PMID:18215538

  18. Electroanalytical sensing of chromium(III) and (VI) utilising gold screen printed macro electrodes.

    PubMed

    Metters, Jonathan P; Kadara, Rashid O; Banks, Craig E

    2012-02-21

    We report the fabrication of gold screen printed macro electrodes which are electrochemically characterised and contrasted to polycrystalline gold macroelectrodes with their potential analytical application towards the sensing of chromium(III) and (VI) critically explored. It is found that while these gold screen printed macro electrodes have electrode kinetics typically one order of magnitude lower than polycrystalline gold macroelectrodes as is measured via a standard redox probe, in terms of analytical sensing, these gold screen printed macro electrodes mimic polycrystalline gold in terms of their analytical performance towards the sensing of chromium(III) and (VI), whilst boasting additional advantages over the macro electrode due to their disposable one-shot nature and the ease of mass production. An additional advantage of these gold screen printed macro electrodes compared to polycrystalline gold is the alleviation of the requirement to potential cycle the latter to form the required gold oxide which aids in the simplification of the analytical protocol. We demonstrate that gold screen printed macro electrodes allow the low micro-molar sensing of chromium(VI) in aqueous solutions over the range 10 to 1600 μM with a limit of detection (3σ) of 4.4 μM. The feasibility of the analytical protocol is also tested through chromium(VI) detection in environmental samples.

  19. Radiological Findings in a case of Advance staged Mesothelioma

    PubMed Central

    Aziz, Fahad

    2009-01-01

    Chest X Ray is the initial screening test for the mesothelioma like all other the chest diseases. But computed tomography (CT) is the imaging technique of choice for charactering pleural masses. CT also gives important information regarding invasion of the chest wall and surrounding structures. Certain CT features help differentiate benign from malignant processes. This short article highlights the salient CT appearance of mesothelioma; the most common pleural tumor. PMID:22263002

  20. Reply to comment on "Validation of two innovative methods to measure contaminant mass flux in groundwater" by Goltz et al. (2009)

    NASA Astrophysics Data System (ADS)

    Goltz, Mark N.; Huang, Junqi

    2014-12-01

    We thank Sun (2014) for his comment on our paper, Goltz et al. (2009). The commenter basically makes two points: (1) equation (6) in Goltz et al. (2009) is incorrect, and (2) screen loss should be further considered as a source of error in the modified integral pump test (MIPT) experiment. We will address each of these points, below.

  1. A proposal to standardize reporting units for fecal immunochemical tests for hemoglobin.

    PubMed

    Fraser, Callum G; Allison, James E; Halloran, Stephen P; Young, Graeme P

    2012-06-06

    Fecal immunochemical tests for hemoglobin are replacing traditional guaiac fecal occult blood tests in population screening programs for many reasons. However, the many available fecal immunochemical test devices use a range of sampling methods, differ with regard to hemoglobin stability, and report hemoglobin concentrations in different ways. The methods for sampling, the mass of feces collected, and the volume and characteristics of the buffer used in the sampling device also vary among fecal immunochemical tests, making comparisons of test performance characteristics difficult. Fecal immunochemical test results may be expressed as the hemoglobin concentration in the sampling device buffer and, sometimes, albeit rarely, as the hemoglobin concentration per mass of feces. The current lack of consistency in units for reporting hemoglobin concentration is particularly problematic because apparently similar hemoglobin concentrations obtained with different devices can lead to very different clinical interpretations. Consistent adoption of an internationally accepted method for reporting results would facilitate comparisons of outcomes from these tests. We propose a simple strategy for reporting fecal hemoglobin concentration that will facilitate the comparison of results between fecal immunochemical test devices and across clinical studies. Such reporting is readily achieved by defining the mass of feces sampled and the volume of sample buffer (with confidence intervals) and expressing results as micrograms of hemoglobin per gram of feces. We propose that manufacturers of fecal immunochemical tests provide this information and that the authors of research articles, guidelines, and policy articles, as well as pathology services and regulatory bodies, adopt this metric when reporting fecal immunochemical test results.

  2. Informing Selection of Nanomaterial Concentrations for ...

    EPA Pesticide Factsheets

    Little justification is generally provided for selection of in vitro assay testing concentrations for engineered nanomaterials (ENMs). Selection of concentration levels for hazard evaluation based on real-world exposure scenarios is desirable. We reviewed published ENM concentrations measured in air in manufacturing and R&D labs to identify input levels for estimating ENM mass retained in the human lung using the Multiple-Path Particle Dosimetry (MPPD) model. Model input parameters were individually varied to estimate alveolar mass retained for different particle sizes (5-1000 nm), aerosol concentrations (0.1, 1 mg/m3), aspect ratios (2, 4, 10, 167), and exposure durations (24 hours and a working lifetime). The calculated lung surface concentrations were then converted to in vitro solution concentrations. Modeled alveolar mass retained after 24 hours is most affected by activity level and aerosol concentration. Alveolar retention for Ag and TiO2 nanoparticles and CNTs for a working lifetime (45 years) exposure duration is similar to high-end concentrations (~ 30-400 μg/mL) typical of in vitro testing reported in the literature. Analyses performed are generally applicable to provide ENM testing concentrations for in vitro hazard screening studies though further research is needed to improve the approach. Understanding the relationship between potential real-world exposures and in vitro test concentrations will facilitate interpretation of toxicological results

  3. Body composition among HIV-seropositive and HIV-seronegative adult patients with pulmonary tuberculosis in Uganda.

    PubMed

    Mupere, Ezekiel; Zalwango, Sarah; Chiunda, Allan; Okwera, Alphonse; Mugerwa, Roy; Whalen, Christopher

    2010-03-01

    We determined whether human immunodeficiency virus (HIV) infection affects body cell mass and fat mass wasting among adults with pulmonary tuberculosis (PTB). We screened 967 Ugandan adults for PTB and HIV infection in a cross-sectional study. We compared anthropometric and bioelectric impedance analysis (BIA) body composition parameters among HIV-seropositive and HIV-seronegative men and women with or without PTB by using a non-parametric test. We found that poor nutritional status associated with TB differed among men and women. Anthropometric and BIA body composition did not differ between HIV-seropositive and HIV-seronegative patients regardless of gender. Average weight group difference in men consisted of body cell mass and fat mass in equal proportions of 43%. In women, average weight group difference consisted predominantly of fat mass of 73% and body cell mass of 13%. Compared to individuals without TB, patients with TB had lower body mass index, weight, body cell mass, and fat mass regardless of gender and HIV status. Gender, but not HIV status, was associated with body composition changes in TB. TB appears to be the dominant factor driving the wasting process among co-infected patients. Copyright (c) 2010 Elsevier Inc. All rights reserved.

  4. Body Composition among HIV-seropositive and HIV-seronegative Adult Patients with Pulmonary Tuberculosis in Uganda

    PubMed Central

    Mupere, Ezekiel; Zalwango, Sarah; Chiunda, Allan; Okwera, Alphonse; Mugerwa, Roy; Whalen, Christopher

    2009-01-01

    Purpose We determined whether human immunodeficiency virus (HIV) infection affects body cell mass and fat mass wasting among adults with pulmonary tuberculosis (PTB). Methods We screened 967 Ugandan adults for PTB and HIV infection in a cross-sectional study. We compared anthropometric and bioelectric impedance analysis (BIA) body composition parameters among HIV-seropositive and HIV-seronegative men and women with or without PTB using a non-parametric test. Results We found that poor nutritional status associated with TB differed among men and women. Anthropometric and BIA body composition did not differ between HIV-seropositive and HIV-seronegative patients regardless of gender. Average weight group difference in men comprised of body cell mass and fat mass in equal proportions of 43%. In women, average weight group difference comprised predominantly of fat mass of 73% and body cell mass of 13%. Compared to individuals without TB, patients with TB had lower body mass index, weight, body cell mass, and fat mass regardless of gender and HIV status. Conclusions Gender but not HIV status was associated with body composition changes in TB. Tuberculosis appears to be the dominant factor driving the wasting process among co-infected patients. PMID:20159491

  5. Top-Down Proteomics and Direct Surface Sampling of Neonatal Dried Blood Spots: Diagnosis of Unknown Hemoglobin Variants

    NASA Astrophysics Data System (ADS)

    Edwards, Rebecca L.; Griffiths, Paul; Bunch, Josephine; Cooper, Helen J.

    2012-11-01

    We have previously shown that liquid microjunction surface sampling of dried blood spots coupled with high resolution top-down mass spectrometry may be used for screening of common hemoglobin variants HbS, HbC, and HbD. In order to test the robustness of the approach, we have applied the approach to unknown hemoglobin variants. Six neonatal dried blood spot samples that had been identified as variants, but which could not be diagnosed by current screening methods, were analyzed by direct surface sampling top-down mass spectrometry. Both collision-induced dissociation and electron transfer dissociation mass spectrometry were employed. Four of the samples were identified as β-chain variants: two were heterozygous Hb D-Iran, one was heterozygous Hb Headington, and one was heterozygous Hb J-Baltimore. The fifth sample was identified as the α-chain variant heterozygous Hb Phnom Penh. Analysis of the sixth sample suggested that it did not in fact contain a variant. Adoption of the approach in the clinic would require speed in both data collection and interpretation. To address that issue, we have compared manual data analysis with freely available data analysis software (ProsightPTM). The results demonstrate the power of top-down proteomics for hemoglobin variant analysis in newborn samples.

  6. Breast cancer biology varies by method of detection and may contribute to overdiagnosis.

    PubMed

    Hayse, Brandon; Hooley, Regina J; Killelea, Brigid K; Horowitz, Nina R; Chagpar, Anees B; Lannin, Donald R

    2016-08-01

    Recently, it has been suggested that screening mammography may result in some degree of overdiagnosis (ie, detection of breast cancers that would never become clinically important within the lifespan of the patient). The extent and biology of these overdiagnosed cancers, however, is not well understood, and the effect of newer screening modalities on overdiagnosis is unknown. We performed a retrospective review of a prospectively collected database of breast cancers diagnosed at the Yale Breast Center from 2004-2014. The mode of initial presentation was categorized into 5 groups: screening mammogram, screening magnetic resonance imaging, screening ultrasonography, self-detected masses, and physician-detected masses. Compared with cancers presenting with masses, cancers detected by image-based screening were more likely to present with ductal carcinoma-in-situ or T1 cancers (P < .001). In addition to a simple stage shift, however, cancers detected by image-based screening were also more likely to be luminal and low-grade cancers; symptomatic cancers were more likely high-grade and triple-negative (P < .001, respectively). On a multivariate analysis, adjusting for age, race, and tumor size, cancers detected by mammogram, US, and magnetic resonance imaging had greater odds of being luminal (odds ratio 1.8, 95% confidence interval, 1.5-2.3; odds ratio 2.2, 95% confidence interval, 1.1-4.7; and odds ratio 4.7, 95% confidence interval, 2.1-10.6, respectively), and low-grade (odds ratio 2.2, 95% confidence interval, 1.6-2.9; odds ratio 4.9, 95% confidence interval, 2.7-8.9; and odds ratio 4.6, 95% confidence interval, 2.6-8.1, respectively) compared with cancers presenting with self-detected masses. Screening detects cancers with more indolent biology, potentially contributing to the observed rate of overdiagnosis. With magnetic resonance imaging and US being used more commonly for screening, the rate of overdiagnosis may increase further. Copyright © 2016. Published by Elsevier Inc.

  7. Suspect screening of large numbers of emerging contaminants in environmental waters using artificial neural networks for chromatographic retention time prediction and high resolution mass spectrometry data analysis.

    PubMed

    Bade, Richard; Bijlsma, Lubertus; Miller, Thomas H; Barron, Leon P; Sancho, Juan Vicente; Hernández, Felix

    2015-12-15

    The recent development of broad-scope high resolution mass spectrometry (HRMS) screening methods has resulted in a much improved capability for new compound identification in environmental samples. However, positive identifications at the ng/L concentration level rely on analytical reference standards for chromatographic retention time (tR) and mass spectral comparisons. Chromatographic tR prediction can play a role in increasing confidence in suspect screening efforts for new compounds in the environment, especially when standards are not available, but reliable methods are lacking. The current work focuses on the development of artificial neural networks (ANNs) for tR prediction in gradient reversed-phase liquid chromatography and applied along with HRMS data to suspect screening of wastewater and environmental surface water samples. Based on a compound tR dataset of >500 compounds, an optimized 4-layer back-propagation multi-layer perceptron model enabled predictions for 85% of all compounds to within 2min of their measured tR for training (n=344) and verification (n=100) datasets. To evaluate the ANN ability for generalization to new data, the model was further tested using 100 randomly selected compounds and revealed 95% prediction accuracy within the 2-minute elution interval. Given the increasing concern on the presence of drug metabolites and other transformation products (TPs) in the aquatic environment, the model was applied along with HRMS data for preliminary identification of pharmaceutically-related compounds in real samples. Examples of compounds where reference standards were subsequently acquired and later confirmed are also presented. To our knowledge, this work presents for the first time, the successful application of an accurate retention time predictor and HRMS data-mining using the largest number of compounds to preliminarily identify new or emerging contaminants in wastewater and surface waters. Copyright © 2015 Elsevier B.V. All rights reserved.

  8. [Detection of respiratory tract diseases among rural population during the team-work mass screening].

    PubMed

    Abramson, E Z; Galkin, V B; Stepanova, G Ia

    1990-01-01

    A screening complex for the examination of the rural population has been worked out to detect bronchopulmonary pathology and form groups of risk for respiratory diseases. The complex of methods included compulsory questionnaires and ++fluoro-functional examination, spirometry if indicated and bacterial tests. Out of 1, 131 persons examined, 328 were found to have respiratory diseases. Chronic non-specific respiratory diseases were detected in 103 subjects, including 62 of them having obstructive bronchitis. A risk group developing chronic non-specific respiratory diseases, including 202 persons with disturbed ventilation activity of the lungs, post-tuberculous inadequate changes and other pathology. Pulmonary tuberculosis was registered in 7 subjects. The given data indicate the necessity of a complex examination of the population.

  9. Stanford GEMS phase 2 obesity prevention trial for low-income African-American girls: design and sample baseline characteristics.

    PubMed

    Robinson, Thomas N; Kraemer, Helena C; Matheson, Donna M; Obarzanek, Eva; Wilson, Darrell M; Haskell, William L; Pruitt, Leslie A; Thompson, Nikko S; Haydel, K Farish; Fujimoto, Michelle; Varady, Ann; McCarthy, Sally; Watanabe, Connie; Killen, Joel D

    2008-01-01

    African-American girls and women are at high risk of obesity and its associated morbidities. Few studies have tested obesity prevention strategies specifically designed for African-American girls. This report describes the design and baseline findings of the Stanford GEMS (Girls health Enrichment Multi-site Studies) trial to test the effect of a two-year community- and family-based intervention to reduce weight gain in low-income, pre-adolescent African-American girls. Randomized controlled trial with measurements scheduled in girls' homes at baseline, 6, 12, 18 and 24 month post-randomization. Low-income areas of Oakland, CA. Eight, nine and ten year old African-American girls and their parents/caregivers. Girls are randomized to a culturally-tailored after-school dance program and a home/family-based intervention to reduce screen media use versus an information-based community health education Active-Placebo Comparison intervention. Interventions last for 2 years for each participant. Change in body mass index over the two-year study. Recruitment and enrollment successfully produced a predominately low-socioeconomic status sample. Two-hundred sixty one (261) families were randomized. One girl per family is randomly chosen for the analysis sample. Randomization produced comparable experimental groups with only a few statistically significant differences. The sample had a mean body mass index (BMI) at the 74 th percentile on the 2000 CDC BMI reference, and one-third of the analysis sample had a BMI at the 95th percentile or above. Average fasting total cholesterol and LDL cholesterol were above NCEP thresholds for borderline high classifications. Girls averaged low levels of moderate to vigorous physical activity, more than 3 h per day of screen media use, and diets high in energy from fat. The Stanford GEMS trial is testing the benefits of culturally-tailored after-school dance and screen-time reduction interventions for obesity prevention in low-income, pre-adolescent African-American girls.

  10. Power of Orbitrap-based LC-high resolution-MS/MS for comprehensive drug testing in urine with or without conjugate cleavage or using dried urine spots after on-spot cleavage in comparison to established LC-MSn or GC-MS procedures.

    PubMed

    Michely, Julian A; Meyer, Markus R; Maurer, Hans H

    2018-01-01

    Reliable, sensitive, and comprehensive urine screening procedures by gas chromatography-mass spectrometry (GC-MS) or liquid chromatography-mass spectrometry (LC-MS) with low or high resolution (HR) are of high importance for drug testing, adherence monitoring, or detection of toxic compounds. Besides conventional urine sampling, dried urine spots are of increasing interest. In the present study, the power of LC-HR-MS/MS was investigated for comprehensive drug testing in urine with or without conjugate cleavage or using dried urine spots after on-spot cleavage in comparison to established LC-MS n or GC-MS procedures. Authentic human urine samples (n = 103) were split in 4 parts. One aliquot was prepared by precipitation (UP), one by UP with conjugate cleavage (UglucP), one spot on filter paper cards and prepared by on-spot cleavage followed by liquid extraction (DUSglucE), and one worked-up by acid hydrolysis, liquid-liquid extraction, and acetylation for GC-MS analysis. The 3 series of LC-HR-MS/MS results were compared among themselves, to corresponding published LC-MS n data, and to screening results obtained by conventional GC-MS. The reference libraries used for the 3 techniques contained over 4500 spectra of parent compounds and their metabolites. The number of all detected hits (770 drug intakes) was set to 100%. The LC-HR-MS/MS approach detected 80% of the hits after UP, 89% after UglucP, and 77% after DUSglucE, which meant over one-third more hits in comparison to the corresponding published LC-MS n results with ≤49% detected hits. The GC-MS approach identified 56% of all detected hits. In conclusion, LC-HR-MS/MS provided the best screening results after conjugate cleavage and precipitation. Copyright © 2017 John Wiley & Sons, Ltd.

  11. Test and evaluation of the 2.4-micron photorefractor ocular screening system

    NASA Technical Reports Server (NTRS)

    Richardson, J. R.

    1985-01-01

    An improved 2.4-m photorefractor ocular screening system was tested and evaluated. The photorefractor system works on the principal of obtaining a colored photograph of both human eyes; and, by analysis of the retinal reflex images, certain ocular defects can be detected such a refractive error, strabismus, and lens obstructions. The 2.4-m photorefractory system uses a 35-mm camera with a telephoto lens and an electronic flash attachment. Retinal reflex images obtained from the new 2.4-m system are significantly improved over earlier systems in image quality. Other features were also improved, notably portability and reduction in mass. A total of 706 school age children were photorefracted, 211 learning disabled and 495 middle school students. The total students having abnormal retinal reflexes were 156 or 22 percent, and 133 or 85 percent of the abnormal had refractive error indicated. Ophthalmological examination was performed on 60 of these students and refractive error was verified in 57 or 95 percent of those examined. The new 2.4-m system has a NASA patent pending and is authorized by the FDA. It provides a reliable means of rapidly screening the eyes of children and young adults for vision problems. It is especially useful for infants and other non-communicative children who cannot be screened by the more conventional methods such as the familiar E chart.

  12. Predicting the risk for colorectal cancer with personal characteristics and fecal immunochemical test.

    PubMed

    Li, Wen; Zhao, Li-Zhong; Ma, Dong-Wang; Wang, De-Zheng; Shi, Lei; Wang, Hong-Lei; Dong, Mo; Zhang, Shu-Yi; Cao, Lei; Zhang, Wei-Hua; Zhang, Xi-Peng; Zhang, Qing-Huai; Yu, Lin; Qin, Hai; Wang, Xi-Mo; Chen, Sam Li-Sheng

    2018-05-01

    We aimed to predict colorectal cancer (CRC) based on the demographic features and clinical correlates of personal symptoms and signs from Tianjin community-based CRC screening data.A total of 891,199 residents who were aged 60 to 74 and were screened in 2012 were enrolled. The Lasso logistic regression model was used to identify the predictors for CRC. Predictive validity was assessed by the receiver operating characteristic (ROC) curve. Bootstrapping method was also performed to validate this prediction model.CRC was best predicted by a model that included age, sex, education level, occupations, diarrhea, constipation, colon mucosa and bleeding, gallbladder disease, a stressful life event, family history of CRC, and a positive fecal immunochemical test (FIT). The area under curve (AUC) for the questionnaire with a FIT was 84% (95% CI: 82%-86%), followed by 76% (95% CI: 74%-79%) for a FIT alone, and 73% (95% CI: 71%-76%) for the questionnaire alone. With 500 bootstrap replications, the estimated optimism (<0.005) shows good discrimination in validation of prediction model.A risk prediction model for CRC based on a series of symptoms and signs related to enteric diseases in combination with a FIT was developed from first round of screening. The results of the current study are useful for increasing the awareness of high-risk subjects and for individual-risk-guided invitations or strategies to achieve mass screening for CRC.

  13. Regional differences as barriers to body mass index screening described by Ohio school nurses.

    PubMed

    Stalter, Ann M; Chaudry, Rosemary V; Polivka, Barbara J

    2011-08-01

    Body mass index (BMI) screening is advocated by the National Association of School Nurses (NASN). Research identifying barriers to BMI screening in public elementary school settings has been sparse. The purpose of the study was to identify barriers and facilitating factors of BMI screening practices among Ohio school nurses working in suburban, rural, and urban public elementary schools. This descriptive study used focus groups with 25 school nurses in 3 geographic regions of Ohio. An adapted Healthy People 2010 model guided the development of semistructured focus group questions. Nine regional themes related to BMI screening emerged specific to suburban, rural, and/or urban school nurses' experiences with BMI screening practice, policy, school physical environment, school social environment, school risk/protection, and access to quality health care. Key facilitating factors to BMI screening varied by region. Key barriers to BMI screening were a lack of privacy, time, policy, and workload of school nurses. Regionally specific facilitating factors to BMI screening in schools provide opportunities for schools to accentuate the positive and to promote school health. © 2011, American School Health Association.

  14. Enzyme immunoassay of Chlamydia in birds.

    PubMed

    Ruppanner, R; Behymer, D E; DeLong, W J; Franti, C E; Schulz, T

    1984-01-01

    Serum samples from 192 free-living birds (27 species) were tested for antibodies against Chlamydia using the enzyme-linked immunosorbent assay (ELISA); 97 (51%) were seropositive. The highest antibody prevalence was among pheasants (96%), ducks (88%), and blackbirds (86%). None of 41 starlings tested were seropositive. The serotesting of 42 confined pheasants indicated 100% exposure to the organism. The ELISA is a sensitive, rapid serologic method that can be of epidemiologic and diagnostic value for detecting exposure to Chlamydia. The ELISA could also be used for mass-screening of pet birds where chlamydiosis may be considered a potential public health hazard.

  15. [Blood sampling using "dried blood spot": a clinical biology revolution underway?].

    PubMed

    Hirtz, Christophe; Lehmann, Sylvain

    2015-01-01

    Blood testing using the dried blood spot (DBS) is used since the 1960s in clinical analysis, mainly within the framework of the neonatal screening (Guthrie test). Since then numerous analytes such as nucleic acids, small molecules or lipids, were successfully measured on the DBS. While this pre-analytical method represents an interesting alternative to classic blood sampling, its use in routine is still limited. We review here the different clinical applications of the blood sampling on DBS and estimate its future place, supported by the new methods of analysis as the LC-MS mass spectrometry.

  16. Factors affecting reproducibility between genome-scale siRNA-based screens

    PubMed Central

    Barrows, Nicholas J.; Le Sommer, Caroline; Garcia-Blanco, Mariano A.; Pearson, James L.

    2011-01-01

    RNA interference-based screening is a powerful new genomic technology which addresses gene function en masse. To evaluate factors influencing hit list composition and reproducibility, we performed two identically designed small interfering RNA (siRNA)-based, whole genome screens for host factors supporting yellow fever virus infection. These screens represent two separate experiments completed five months apart and allow the direct assessment of the reproducibility of a given siRNA technology when performed in the same environment. Candidate hit lists generated by sum rank, median absolute deviation, z-score, and strictly standardized mean difference were compared within and between whole genome screens. Application of these analysis methodologies within a single screening dataset using a fixed threshold equivalent to a p-value ≤ 0.001 resulted in hit lists ranging from 82 to 1,140 members and highlighted the tremendous impact analysis methodology has on hit list composition. Intra- and inter-screen reproducibility was significantly influenced by the analysis methodology and ranged from 32% to 99%. This study also highlighted the power of testing at least two independent siRNAs for each gene product in primary screens. To facilitate validation we conclude by suggesting methods to reduce false discovery at the primary screening stage. In this study we present the first comprehensive comparison of multiple analysis strategies, and demonstrate the impact of the analysis methodology on the composition of the “hit list”. Therefore, we propose that the entire dataset derived from functional genome-scale screens, especially if publicly funded, should be made available as is done with data derived from gene expression and genome-wide association studies. PMID:20625183

  17. Metastatic prostate cancer in the modern era of PSA screening

    PubMed Central

    Fontenot, Philip A.; Nehra, Avinash; Parker, William; Wyre, Hadley; Mirza, Moben; Duchene, David A.; Holzbeierlein, Jeffrey; Thrasher, James Brantley; Veldhuizen, Peter Van; Lee, Eugene K.

    2017-01-01

    ABSTRACT Introduction To characterize initial presentation and PSA screening status in a contemporary cohort of men treated for metastatic prostate cancer at our institution. Materials and methods We reviewed records of 160 men treated for metastatic prostate cancer between 2008-2014 and assessed initial presentation, categorizing patients into four groups. Groups 1 and 2 presented with localized disease and received treatment. These men suffered biochemical recurrence late (>1 year) or earlier (<1 year), respectively, and developed metastases. Groups 3 and 4 had asymptomatic and symptomatic metastases at the outset of their diagnosis. Patients with a first PSA at age 55 or younger were considered to have guideline-directed screening. Results Complete records were available on 157 men for initial presentation and 155 men for PSA screening. Groups 1, 2, 3 and 4 included 27 (17%), 7 (5%), 69 (44%) and 54 (34%) patients, respectively. Twenty (13%) patients received guideline-directed PSA screening, 5/155 (3%) patients presented with metastases prior to age 55 with their first PSA, and 130/155 (84%) had their first PSA after age 55, of which 122/130 (94%) had metastasis at the time of diagnosis. Conclusion Despite widespread screening, most men treated for metastatic prostate cancer at our institution presented with metastases rather than progressed after definitive treatment. Furthermore, 25 (16%) patients received guideline-directed PSA screening at or before age 55. These data highlight that, despite mass screening efforts, patients treated for incurable disease at our institution may not have been a result of a failed screening test, but a failure to be screened. PMID:28338310

  18. Screening for the synthetic cannabinoid JWH-018 and its major metabolites in human doping controls.

    PubMed

    Möller, Ines; Wintermeyer, Annette; Bender, Katja; Jübner, Martin; Thomas, Andreas; Krug, Oliver; Schänzer, Wilhelm; Thevis, Mario

    2011-09-01

    Referred to as 'spice', several new drugs, advertised as herbal blends, have appeared on the market in the last few years, in which the synthetic cannabinoids JWH-018 and a C(8) homologue of CP 47,497 were identified as major active ingredients. Due to their reported cannabis-like effects, many European countries have banned these substances. The World Anti-Doping Agency has also explicitly prohibited synthetic cannabinoids in elite sport in-competition. Since urine specimens have been the preferred doping control samples, the elucidation of the metabolic pathways of these substances is of particular importance to implement them in sports drug testing programmes. In a recent report, an in vitro phase-I metabolism study of JWH-018 was presented yielding mainly hydroxylated and N-dealkylated metabolites. Due to these findings, a urine sample of a healthy man declaring to have smoked a 'spice' product was screened for potential phase-I and -II metabolites by high-resolution/high-accuracy mass spectrometry in the present report. The majority of the phase-I metabolites observed in earlier in vitro studies of JWH-018 were detected in this urine specimen and furthermore most of their respective monoglucuronides. As no intact JWH-018 was detectable, the monohydroxylated metabolite being the most abundant one was chosen as a target analyte for sports drug testing purposes; a detection method was subsequently developed and validated in accordance to conventional screening protocols based on enzymatic hydrolysis, liquid-liquid extraction, and liquid chromatography/electrospray tandem mass spectrometry analysis. The method was applied to approximately 7500 urine doping control samples yielding two JWH-018 findings and demonstrated its capability for a sensitive and selective identification of JWH-018 and its metabolites in human urine. Copyright © 2010 John Wiley & Sons, Ltd.

  19. Mass screening and treatment on the basis of results of a Plasmodium falciparum-specific rapid diagnostic test did not reduce malaria incidence in Zanzibar.

    PubMed

    Cook, Jackie; Xu, Weiping; Msellem, Mwinyi; Vonk, Marlotte; Bergström, Beatrice; Gosling, Roly; Al-Mafazy, Abdul-Wahid; McElroy, Peter; Molteni, Fabrizio; Abass, Ali K; Garimo, Issa; Ramsan, Mahdi; Ali, Abdullah; Mårtensson, Andreas; Björkman, Anders

    2015-05-01

    Seasonal increases in malaria continue in hot spots in Zanzibar. Mass screening and treatment (MSAT) may help reduce the reservoir of infection; however, it is unclear whether rapid diagnostic tests (RDTs) detect a sufficient proportion of low-density infections to influence subsequent transmission. Two rounds of MSAT using Plasmodium falciparum-specific RDT were conducted in 5 hot spots (population, 12 000) in Zanzibar in 2012. In parallel, blood samples were collected on filter paper for polymerase chain reaction (PCR) analyses. Data on confirmed malarial parasite infections from health facilities in intervention and hot spot control areas were monitored as proxy for malaria transmission. Approximately 64% of the population (7859) were screened at least once. P. falciparum prevalence, as measured by RDT, was 0.2% (95% confidence interval [CI], .1%-.3%) in both rounds, compared with PCR measured prevalences (for all species) of 2.5% (95% CI, 2.1%-2.9%) and 3.8% (95% CI, 3.2%-4.4%) in rounds 1 and 2, respectively. Two fifths (40%) of infections detected by PCR included non-falciparum species. Treatment of RDT-positive individuals (4% of the PCR-detected parasite carriers) did not reduce subsequent malaria incidence, compared with control areas. Highly sensitive point-of-care diagnostic tools for detection of all human malaria species are needed to make MSAT an effective strategy in settings where malaria elimination programs are in the pre-elimination phase. © The Author 2014. Published by Oxford University Press on behalf of the Infectious Diseases Society of America. All rights reserved. For Permissions, please e-mail: journals.permissions@oup.com.

  20. Comparison of 1 mg and 2 mg overnight dexamethasone suppression tests for the screening of Cushing's syndrome in obese patients.

    PubMed

    Sahin, Mustafa; Kebapcilar, Levent; Taslipinar, Abdullah; Azal, Omer; Ozgurtas, Taner; Corakci, Ahmet; Akgul, Emin Ozgur; Taslipinar, Mine Yavuz; Yazici, Mahmut; Kutlu, Mustafa

    2009-01-01

    Obesity is currently a major public health problem and one of the potential underlying causes of obesity in a minority of patients is Cushing's syndrome (CS). Traditionally, the gold standard screening test for CS is 1 mg dexamethasone overnight suppression test. However, it is known that obese subjects have high false positive results with this test. We have therefore compared the 1 mg and 2 mg overnight dexamethasone suppression tests in obese subjects. Patients whose serum cortisol after ODST was >50 nM underwent and a low-dose dexamethasone suppression test (LDDST); 24-hour urine cortisol was collected for basal urinary free cortisol (UFC). For positive results after overnight 1-mg dexamethasone suppression test we also performed the overnight 2-mg dexamethasone suppression test. We prospectively evaluated 100 patients (22 men and 78 women, ranging in age from 17 to 73 years with a body mass index (BMI) >30 kg/m2 who had been referred to our hospital-affiliated endocrine clinic because of simple obesity. Suppression of serum cortisol to <50 nM (1.8 microg/dL) after dexamethasone administration was chosen as the cut-off point for normal suppression. Thyroid function tests, lipid profiles, homocysteine, antithyroglobulin, anti-thyroid peroxidase antibody levels, vitamin B12, folate levels, insulin resistance [by homeostasis model assessment (HOMA)] and 1.0 mg postdexamethasone (postdex) suppression cortisol levels were measured. We found an 8% false-positive rate in 1 mg overnight test and 2% in 2 mg overnight test (p=0.001). There was no correlation between the cortisol levels after ODST and other parameters. Our results indicate that the 2 mg overnight dexamethasone suppression test (ODST) is more convenient and accurate than 1-mg ODST as a screening test for excluding CS in subjects with simple obesity.

  1. Non-Target Screening of Veterinary Drugs Using Tandem Mass Spectrometry on SmartMass

    NASA Astrophysics Data System (ADS)

    Xia, Bing; Liu, Xin; Gu, Yu-Cheng; Zhang, Zhao-Hui; Wang, Hai-Yan; Ding, Li-Sheng; Zhou, Yan

    2013-05-01

    Non-target screening of veterinary drugs using tandem mass spectrometric data was performed on the SmartMass platform. This newly developed software uses the characteristic fragmentation patterns (CFP) to identify chemicals, especially those containing particular substructures. A mixture of 17 sulfonamides was separated by ultra performance liquid chromatography (UPLC), and SmartMass was used to process the tandem mass spectrometry (MS/MS) data acquired on an Orbitrap mass spectrometer. The data were automatically extracted, and each sulfonamide was recognized and analyzed with a prebuilt analysis rule. By using this software, over 98 % of the false candidate structures were eliminated, and all the correct structures were found within the top 10 of the ranking lists. Furthermore, SmartMass could also be used to identify slightly modified contraband drugs and metabolites with simple prebuilt rules. [Figure not available: see fulltext.

  2. Sedentary Behavior Is Independently Related to Fat Mass among Children and Adolescents in South China.

    PubMed

    Xue, Hongmei; Tian, Guo; Duan, Ruonan; Quan, Liming; Zhao, Li; Yang, Min; Libuda, Lars; Muckelbauer, Rebecca; Cheng, Guo

    2016-10-25

    We aim to explore the independent associations of sedentary behaviors (SB) with body mass distribution among Chinese children. Data on the screen-based sedentary time (television viewing and computer use) and doing homework, physical activities and dietary intake of 1586 Chinese children (50.3% girls) aged 7-15 years were obtained through validated questionnaires. Skin-fold thickness, body height, and weight were measured to calculate percent body fat (%BF), fat mass index (FMI), and fat-free mass index (FFMI). Parental characteristics were collected by questionnaires. Among girls, time of SB (screen time or doing homework) was positively related to %BF, FMI, and FFMI ( p < 0.03) after adjusting for maternal overweight, the average annual income of family, moderate-to-vigorous physical activity energy expenditure, and energy intake: Girls in the highest tertile of screen time/homework had 16.7%/23.3% higher relative FMI and 2.9%/2.9% higher relative FFMI than girls in the lowest tertile. Among boys, screen time was positively associated with FFMI ( p < 0.003), but not related to %BF and FMI ( p > 0.09), while time of doing homework was positively related to %BF and FMI ( p = 0.03). Sedentary behaviors might be positively and independently related to fat mass among Chinese children, and were more pronounced in girls.

  3. Current use of high-resolution mass spectrometry in drug screening relevant to clinical and forensic toxicology and doping control.

    PubMed

    Ojanperä, Ilkka; Kolmonen, Marjo; Pelander, Anna

    2012-05-01

    Clinical and forensic toxicology and doping control deal with hundreds or thousands of drugs that may cause poisoning or are abused, are illicit, or are prohibited in sports. Rapid and reliable screening for all these compounds of different chemical and pharmaceutical nature, preferably in a single analytical method, is a substantial effort for analytical toxicologists. Combined chromatography-mass spectrometry techniques with standardised reference libraries have been most commonly used for the purpose. In the last ten years, the focus has shifted from gas chromatography-mass spectrometry to liquid chromatography-mass spectrometry, because of progress in instrument technology and partly because of the polarity and low volatility of many new relevant substances. High-resolution mass spectrometry (HRMS), which enables accurate mass measurement at high resolving power, has recently evolved to the stage that is rapidly causing a shift from unit-resolution, quadrupole-dominated instrumentation. The main HRMS techniques today are time-of-flight mass spectrometry and Orbitrap Fourier-transform mass spectrometry. Both techniques enable a range of different drug-screening strategies that essentially rely on measuring a compound's or a fragment's mass with sufficiently high accuracy that its elemental composition can be determined directly. Accurate mass and isotopic pattern acts as a filter for confirming the identity of a compound or even identification of an unknown. High mass resolution is essential for improving confidence in accurate mass results in the analysis of complex biological samples. This review discusses recent applications of HRMS in analytical toxicology.

  4. Parents of Elementary School Students Weigh in on Height, Weight, and Body Mass Index Screening at School

    ERIC Educational Resources Information Center

    Kubik, Martha Y.; Fulkerson, Jayne A.; Story, Mary; Rieland, Gayle

    2006-01-01

    School-based body mass index (BMI) screening and parent notification programs have been recommended as a childhood overweight prevention strategy. However, there are little empirical data available to guide decision making about the acceptability and safety of programs. A pilot study was conducted using a quasiexperimental research design. In fall…

  5. Neutral desorption extractive electrospray ionization mass spectrometry for fast screening sunscreen agents in cream cosmetic products.

    PubMed

    Zhang, Xinglei; Liu, Yan; Zhang, Jinghua; Hu, Zhong; Hu, Bin; Ding, Liying; Jia, Li; Chen, Huanwen

    2011-09-15

    High throughput analysis of sunscreen agents present in cream cosmetic has been demonstrated, typically 2 samples per minute, using neutral desorption extractive electrospray ionization mass spectrometry (ND-EESI-MS) without sample pretreatment. For the targeted compounds such as 4-Aminobenzoic acid and oxybenzone, ND-EESI-MS method provided linear signal responses in the range of 1-100 ppb. Limits of detection (LOD) of the method were estimated at sub-ppb levels for the analytes tested. Reasonable relative standard deviation (RSD=8.4-16.0%) was obtained as a result of 10 independent measurements for commercial cosmetics samples spiked with each individual sunscreen agents at 1-10 ppb. Acceptable recoveries were achieved in the range of 87-116% for direct analysis of commercial cream cosmetic samples. The experimental data demonstrate that ND-EESI-MS is a useful tool for high throughput screening of sunscreen agents in highly viscous cream cosmetic products, with the capability to obtain quantitative information of the analytes. Copyright © 2011 Elsevier B.V. All rights reserved.

  6. Screening the psychological laboratory: Hugo Münsterberg, psychotechnics, and the cinema, 1892-1916.

    PubMed

    Blatter, Jeremy

    2015-03-01

    According to Hugo Münsterberg, the direct application of experimental psychology to the practical problems of education, law, industry, and art belonged by definition to the domain of psychotechnics. Whether in the form of pedagogical prescription, interrogation technique, hiring practice, or aesthetic principle, the psychotechnical method implied bringing the psychological laboratory to bear on everyday life. There were, however, significant pitfalls to leaving behind the putative purity of the early psychological laboratory in pursuit of technological utility. In the Vocation Bureau, for example, psychological instruments were often deemed too intimidating for a public unfamiliar with the inner workings of experimental science. Similarly, when psychotechnical means were employed by big business in screening job candidates, ethical red flags were raised about this new alliance between science and capital. This tension was particularly evident in Münsterberg's collaboration with the Paramount Pictures Corporation in 1916. In translating psychological tests into short experimental films, Münsterberg not only envisioned a new mass medium for the dissemination of psychotechnics, but a means by which to initiate the masses into the culture of experimental psychology.

  7. Attitudes towards screening for lung cancer among smokers and their non-smoking counterparts.

    PubMed

    Silvestri, Gerard A; Nietert, Paul J; Zoller, James; Carter, Cindy; Bradford, David

    2007-02-01

    There has been resurgence of interest in lung cancer screening using low-dose computed tomography. The implications of directing a screening programme at smokers has been little explored. A nationwide telephone survey was conducted. Demographics, certain clinical characteristics and attitudes about screening for lung cancer were ascertained. Responses of current, former and never smokers were compared. 2001 people from the US were interviewed. Smokers were significantly (p < 0.05) more likely than never smokers to be male, non-white, less educated, and to report poor health status or having had cancer, and less likely to be able to identify a usual source of healthcare. Compared with never smokers, current smokers were less likely to believe that early detection would result in a good chance of survival (p < 0.05). Smokers were less likely to be willing to consider computed tomography screening for lung cancer (71.2% (current smokers) v 87.6% (never smokers) odds ratio (OR) 0.48; 95% confidence interval (CI) 0.32 to 0.71). More never smokers as opposed to current smokers believed that the risk of disease (88% v 56%) and the accuracy of the test (92% v 71%) were important determinants in deciding whether to be screened (p < 0.05). Only half of the current smokers would opt for surgery for a screen-diagnosed cancer. The findings suggest that there may be substantial obstacles to the successful implementation of a mass-screening programme for lung cancer that will target cigarette smokers.

  8. The Vertical Drop Jump Is a Poor Screening Test for ACL Injuries in Female Elite Soccer and Handball Players: A Prospective Cohort Study of 710 Athletes.

    PubMed

    Krosshaug, Tron; Steffen, Kathrin; Kristianslund, Eirik; Nilstad, Agnethe; Mok, Kam-Ming; Myklebust, Grethe; Andersen, Thor Einar; Holme, Ingar; Engebretsen, Lars; Bahr, Roald

    2016-04-01

    The evidence linking knee kinematics and kinetics during a vertical drop jump (VDJ) to anterior cruciate ligament (ACL) injury risk is restricted to a single small sample. Still, the VDJ test continues to be advocated for clinical screening purposes. To test whether 5 selected kinematic and kinetic variables were associated with future ACL injuries in a large cohort of Norwegian female elite soccer and handball players. Furthermore, we wanted to assess whether the VDJ test can be recommended as a screening test to identify players with increased risk. Cohort study; Level of evidence, 2. Elite female soccer and handball players participated in preseason screening tests from 2007 through 2014. The tests included marker-based 3-dimensional motion analysis of a drop-jump landing. We followed a predefined statistical protocol in which we included the following candidate risk factors in 5 separate logistic regression analyses, with new ACL injury as the outcome: (1) knee valgus angle at initial contact, (2) peak knee abduction moment, (3) peak knee flexion angle, (4) peak vertical ground-reaction force, and (5) medial knee displacement. A total of 782 players were tested (age, 21 ± 4 years; height, 170 ± 7 cm; body mass, 67 ± 8 kg), of which 710 were included in the analyses. We registered 42 new noncontact ACL injuries, including 12 in previously ACL-injured players. Previous ACL injury (relative risk, 3.8; 95% CI, 2.1-7.1) and medial knee displacement (odds ratio, 1.40; 95% CI, 1.12-1.74 per 1-SD change) were associated with increased risk for injury. However, among the 643 players without previous injury, we found no association with medial knee displacement. A receiver operating characteristic curve analysis of medial knee displacement showed an area under the curve of 0.6, indicating a poor-to-failed combined sensitivity and specificity of the test, even when including previously injured players. Of the 5 risk factors considered, medial knee displacement was the only factor associated with increased risk for ACL. However, receiver operating characteristic curve analysis indicated a poor combined sensitivity and specificity when medial knee displacement was used as a screening test for predicting ACL injury. For players with no previous injury, none of the VDJ variables were associated with increased injury risk. VDJ tests cannot predict ACL injuries in female elite soccer and handball players. © 2016 The Author(s).

  9. Using In Silico Fragmentation to Improve Routine Residue Screening in Complex Matrices.

    PubMed

    Kaufmann, Anton; Butcher, Patrick; Maden, Kathryn; Walker, Stephan; Widmer, Mirjam

    2017-12-01

    Targeted residue screening requires the use of reference substances in order to identify potential residues. This becomes a difficult issue when using multi-residue methods capable of analyzing several hundreds of analytes. Therefore, the capability of in silico fragmentation based on a structure database ("suspect screening") instead of physical reference substances for routine targeted residue screening was investigated. The detection of fragment ions that can be predicted or explained by in silico software was utilized to reduce the number of false positives. These "proof of principle" experiments were done with a tool that is integrated into a commercial MS vendor instrument operating software (UNIFI) as well as with a platform-independent MS tool (Mass Frontier). A total of 97 analytes belonging to different chemical families were separated by reversed phase liquid chromatography and detected in a data-independent acquisition (DIA) mode using ion mobility hyphenated with quadrupole time of flight mass spectrometry. The instrument was operated in the MS E mode with alternating low and high energy traces. The fragments observed from product ion spectra were investigated using a "chopping" bond disconnection algorithm and a rule-based algorithm. The bond disconnection algorithm clearly explained more analyte product ions and a greater percentage of the spectral abundance than the rule-based software (92 out of the 97 compounds produced ≥1 explainable fragment ions). On the other hand, tests with a complex blank matrix (bovine liver extract) indicated that the chopping algorithm reports significantly more false positive fragments than the rule based software. Graphical Abstract.

  10. Using In Silico Fragmentation to Improve Routine Residue Screening in Complex Matrices

    NASA Astrophysics Data System (ADS)

    Kaufmann, Anton; Butcher, Patrick; Maden, Kathryn; Walker, Stephan; Widmer, Mirjam

    2017-12-01

    Targeted residue screening requires the use of reference substances in order to identify potential residues. This becomes a difficult issue when using multi-residue methods capable of analyzing several hundreds of analytes. Therefore, the capability of in silico fragmentation based on a structure database ("suspect screening") instead of physical reference substances for routine targeted residue screening was investigated. The detection of fragment ions that can be predicted or explained by in silico software was utilized to reduce the number of false positives. These "proof of principle" experiments were done with a tool that is integrated into a commercial MS vendor instrument operating software (UNIFI) as well as with a platform-independent MS tool (Mass Frontier). A total of 97 analytes belonging to different chemical families were separated by reversed phase liquid chromatography and detected in a data-independent acquisition (DIA) mode using ion mobility hyphenated with quadrupole time of flight mass spectrometry. The instrument was operated in the MSE mode with alternating low and high energy traces. The fragments observed from product ion spectra were investigated using a "chopping" bond disconnection algorithm and a rule-based algorithm. The bond disconnection algorithm clearly explained more analyte product ions and a greater percentage of the spectral abundance than the rule-based software (92 out of the 97 compounds produced ≥1 explainable fragment ions). On the other hand, tests with a complex blank matrix (bovine liver extract) indicated that the chopping algorithm reports significantly more false positive fragments than the rule based software. [Figure not available: see fulltext.

  11. Screening douglas-fir for rapid early growth in common-garden tests in spain. Forest Service general technical report (Final)

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Hernandez, G.T.; Alonso, G.V.; Arribas, G.P.

    1993-08-01

    Douglas-firs from 91 seed sources in North America were evaluated after 5 and 6 years in 15 common-garden tests in the mountainous regions of northwest and north central Spain. Analyses of tallest trees showed that most of the sources of highest potential for reforestation in Spain are found in regions where the Pacific Ocean air mass dominates climate. Fast growers came from coastal slopes of the Coast Ranges from northwest California to the Georgia Strait of southwest British Columbia and inland slopes of the Olympic Mountains and Coast and Cascade Ranges facing the Puget Trough in western Washington and Willamettemore » Valley in northwest Oregon. Slow growers came from latitudes south of 44 deg and north of 50 deg, high altitudes west of the crest of the Cascade Ranges, and regions east of the crest where the continental air mass dominated climate.« less

  12. DOE Office of Scientific and Technical Information (OSTI.GOV)

    James, Veronica J.; ANU)

    An early diagnosis of malignancies correlates directly with a better prognosis. Yet for many malignancies there are no readily available, noninvasive, cost-effective diagnostic tests with patients often presenting too late for effective treatment. This article describes for the first time the use of fiber diffraction patterns of skin or fingernails, using X-ray sources, as a biometric diagnostic method for detecting neoplastic disorders including but not limited to melanoma, breast, colon and prostate cancers. With suitable further development, an early low-cost, totally noninvasive yet reliable diagnostic test could be conducted on a regular basis in local radiology facilities, as a confirmatorymore » test for other diagnostic procedures or as a mass screening test using suitable small angle X-ray beam-lines at synchrotrons.« less

  13. Impact of comorbid conditions on participation in an organised colorectal cancer screening programme: a cross-sectional study.

    PubMed

    Guiriguet, Carolina; Pera, Guillem; Castells, Antoni; Toran, Pere; Grau, Jaume; Rivero, Irene; Buron, Andrea; Macià, Francesc; Vela-Vallespín, Carmen; Vilarrubí-Estrella, Mercedes; Marzo-Castillejo, Mercedes

    2017-08-07

    There is controversy regarding how comorbidity impacts on colorectal cancer screening, especially in the context of organised programmes. The aim of this study is to assess the effect of comorbidities on participation in the Barcelona population-based colorectal cancer screening programme (BCCSP). Cross-sectional study carried out in ten primary care centres involved in the BCCSP. Individuals aged 50 to 69, at average risk of colorectal cancer, who were invited to participate in the first round of the faecal immunochemical test-based BCCSP were included (2011-2012). The main variable was participation in the BCCSP. Comorbidity was assessed by clinical risk group status. Other adjusting variables were age, sex, socioeconomic deprivation, visits to primary care, smoking, alcohol consumption and body mass index. Logistic regression models were used to test the association between participation in the programme and potential explanatory variables. The results were given as incidence rate ratios (IRR) and their 95% confidence intervals (CI). Of the 36,208 individuals included, 17,404 (48%) participated in the BCCSP. Participation was statistically significantly higher in women, individuals aged 60 to 64, patients with intermediate socioeconomic deprivation, and patients with more medical visits. There was a higher rate of current smoking, high-risk alcohol intake, obesity and individuals in the highest comorbidity categories in the non-participation group. In the adjusted analysis, only individuals with multiple minor chronic diseases were more likely to participate in the BCCSP (IRR 1.14; 95% CI [1.06 to 1.22]; p < 0.001). In contrast, having three or more dominant chronic diseases was associated with lower participation in the screening programme (IRR 0.76; 95% CI [0.65 to 0.89]; p = 0.001). Having three or more dominant chronic diseases, was associated with lower participation in a faecal immunochemical test-based colorectal cancer screening programme, whereas individuals with multiple minor chronic diseases were more likely to participate. Further research is needed to explore comorbidity as a cause of non-participation in colorectal cancer screening programmes and which individuals could benefit most from colorectal cancer screening.

  14. Reliability of the cloned-enzyme donor immunoassay (CEDIA) for cocaine in human serum in the range between the detection limit and the cut-off.

    PubMed

    Schütz, Harald; Auch, Jürgen; Erdmann, Freidoon; Weiler, Günter; Verhoff, Marcel A

    2006-01-01

    Immunoassays are used worldwide for the rapid screening of drugs. Despite the fact that they are highly valuable tools for the testing of legal and illicit drugs, there is a non-negligable risk of false-positive and false-negative findings and many pitfalls must be taken into account when using these tests in an uncritical manner and without valid confirmation procedures. In order to check the correlation between cloned-enzyme donor immunoassay (CEDIA) readings and exact determined gas chromatography/mass spectrometry (GC/MS) values for benzoylecgonine, a total of 472 serum samples was measured with an immunoassay (CEDIA) as well as GC/MS. As a result, it was shown that in the lower area of concentration, up to approx. 300 ng equ. benzoylecgonine/ml, there is a semiquantitative useful correlation. With higher concentrations, the values shift more and more apart and many runaways are visible. Generally the use of tests for materials other than those declared is excluded from the manufacturer's warranty and is at the user's own risk, but the authors found that many immunochemical tests with a certification only for the use in urine are well suited to the screening of serum samples, and even low readings could be confirmed by GC/MS. With blood or serum as sample, it could be regularly observed that generally very small readings could not only be confirmed with mass spectrometry but could in most cases also be quantified. This was the key factor in determining the rate of confirmation in 495 cases. In total, an incredibly high reliability for the CEDIA cocaine test (via benzoylecgonine) was shown up to the area of detection (detection limit), far below the cut-off. These results confirm the extraordinary sensitivity and specificity of this test also for blood or serum as sample material to be tested.

  15. Passive cannabis smoke exposure and oral fluid testing.

    PubMed

    Niedbala, Sam; Kardos, Keith; Salamone, Sal; Fritch, Dean; Bronsgeest, Matth; Cone, Edward J

    2004-10-01

    Oral fluid testing for Delta(9)-tetrahydrocannabinol (THC) provides a convenient means of detection of recent cannabis usage. In this study, the risk of positive oral fluid tests from passive cannabis smoke exposure was investigated by housing four cannabis-free volunteers in a small, unventilated, and sealed room with an approximate volume of 36 m(3). Five active cannabis smokers were also present in the room, and each smoked a single cannabis cigarette (1.75% THC). Cannabis smoking occurred over the first 20 min of the study session. All subjects remained in the room for approximately 4 h. Oral fluid specimens were collected with the Intercept DOA Oral Specimen Collection Device. Three urine specimens were collected (0, 20, and 245 min). In addition, three air samples were collected for measurement of THC content. All oral fluid specimens were screened by enzyme immunoassay (EIA) for cannabinoids (cutoff concentration = 3 ng/mL) and tested by gas chromatography-tandem mass spectrometry (GC-MS-MS) for THC (LOQ/LOD = 0.75 ng/mL). All urine specimens were screened by EIA for cannabinoids (cutoff concentration = 50 ng/mL) and tested by GC-MS-MS for THCCOOH (LOQ/LOD = 1 ng/mL). Air samples were measured for THC by GC-MS (LOD = 1 ng/L). A total of eight oral fluid specimens (collected 20 to 50 min following initiation of smoking) from the four passive subjects screened and confirmed positive for THC at concentrations ranging from 3.6 to 26.4 ng/mL. Two additional specimens from one passive subject, collected at 50 and 65 min, screened negative but contained THC in concentrations of 4.2 and 1.1 ng/mL, respectively. All subsequent specimens for passive participants tested negative by EIA and GC-MS-MS for the remainder of the 4-h session. In contrast, oral fluid specimens collected from the five cannabis smokers generally screened and confirmed positive for THC throughout the session at concentrations substantially higher than observed for passive subjects. Urine specimens from active cannabis smokers also screened and confirmed positive at conventional cutoff concentrations. A biphasic pattern of decline for THC was observed in oral fluid specimens collected from cannabis smokers, whereas a linear decline was seen for passive subjects suggesting that initial oral fluid contamination is cleared rapidly and is followed by THC sequestration in the oral mucosa. It is concluded that the risk of positive oral fluid tests from passive cannabis smoke inhalation is limited to a period of approximately 30 min following exposure.

  16. Is Preoperative Biochemical Testing for Pheochromocytoma Necessary for All Adrenal Incidentalomas?

    PubMed Central

    Jun, Joo Hyun; Ahn, Hyun Joo; Lee, Sangmin M.; Kim, Jie Ae; Park, Byung Kwan; Kim, Jee Soo; Kim, Jung Han

    2015-01-01

    Abstract This study examined whether imaging phenotypes obtained from computed tomography (CT) can replace biochemical tests to exclude pheochromocytoma among adrenal incidentalomas (AIs) in the preoperative setting. We retrospectively reviewed the medical records of all patients (n = 251) who were admitted for operations and underwent adrenal-protocol CT for an incidentally discovered adrenal mass from January 2011 to December 2012. Various imaging phenotypes were assessed for their screening power for pheochromocytoma. Final diagnosis was confirmed by biopsy, biochemical tests, and follow-up CT. Pheochromocytomas showed similar imaging phenotypes as malignancies, but were significantly different from adenomas. Unenhanced attenuation values ≤10 Hounsfield units (HU) showed the highest specificity (97%) for excluding pheochromocytoma as a single phenotype. A combination of size ≤3 cm, unenhanced attenuation values ≤ 10 HU, and absence of suspicious morphology showed 100% specificity for excluding pheochromocytoma. Routine noncontrast CT can be used as a screening tool for pheochromocytoma by combining 3 imaging phenotypes: size ≤3 cm, unenhanced attenuation values ≤10 HU, and absence of suspicious morphology, and may substitute for biochemical testing in the preoperative setting. PMID:26559265

  17. Imaging and Screening of Cancer of the Gallbladder and Bile Ducts.

    PubMed

    Sandrasegaran, Kumar; Menias, Christine O

    2017-11-01

    Biliary cancers include gallbladder cancer (GBC) and cholangiocarcinoma (CCA). GBC may appear as a mass replacing the gallbladder, thickened gallbladder wall, or polypoid lesion in the gallbladder. Gallbladder polyps with low risk of GBC (eg, 6- to 10-mm polyps without other risk factors) are screened with sonography. In general, polyps smaller than 5 mm are ignored and those larger than 10 mm require surgical consideration. Screening for CCA is less well-established. On imaging, CCA may be divided into mass-forming, periductal infiltrating, and intraductal types. This review discusses the current state of screening and diagnosis of GBC and CCA. Copyright © 2017 Elsevier Inc. All rights reserved.

  18. Enabling multiplexed testing of pooled donor cells through whole-genome sequencing.

    PubMed

    Chan, Yingleong; Chan, Ying Kai; Goodman, Daniel B; Guo, Xiaoge; Chavez, Alejandro; Lim, Elaine T; Church, George M

    2018-04-19

    We describe a method that enables the multiplex screening of a pool of many different donor cell lines. Our method accurately predicts each donor proportion from the pool without requiring the use of unique DNA barcodes as markers of donor identity. Instead, we take advantage of common single nucleotide polymorphisms, whole-genome sequencing, and an algorithm to calculate the proportions from the sequencing data. By testing using simulated and real data, we showed that our method robustly predicts the individual proportions from a mixed-pool of numerous donors, thus enabling the multiplexed testing of diverse donor cells en masse.More information is available at https://pgpresearch.med.harvard.edu/poolseq/.

  19. Inborn Error of Metabolism (IEM) screening in Singapore by electrospray ionization-tandem mass spectrometry (ESI/MS/MS): An 8 year journey from pilot to current program.

    PubMed

    Lim, J S; Tan, E S; John, C M; Poh, S; Yeo, S J; Ang, J S M; Adakalaisamy, P; Rozalli, R A; Hart, C; Tan, E T H; Ranieri, E; Rajadurai, V S; Cleary, M A; Goh, D L M

    2014-01-01

    IEM screening by ESI/MS/MS was introduced in Singapore in 2006. There were two phases; a pilot study followed by implementation of the current program. The pilot study was over a 4 year period. During the pilot study, a total of 61,313 newborns were screened, and 20 cases of IEM were diagnosed (detection rate of 1:3065; positive predictive value (PPV) of 11%). Regular self-review, participation in external quality assessment and the Region 4 Genetic collaborative programs (http://www.region4genetics.org/) had led to the robust development of our current NBS MS/MS program. Overall, from July 2006 to April 2014, we screened a total of 177,267 newborns. The mean age at the time of sampling was 47.9h. Transportation of samples to the testing laboratory averaged 0.92 day. Upon receipt of sample, the NBS result was available within 1.64 days and within 3.8 days if a second tier test was required. Using absolute cut-off values in place of the initial 99th percentile reference range for the analyte markers and the introduction of two 2nd tier tests (MMA and Succinylacetone) had significantly reduced the high recall rate from an initial 1.5% during the period 2006-07 to 0.12% in 2013. The NBS MS/MS program was supported by a centralized confirmatory/diagnostic testing laboratory and a rapid response team of metabolic specialists. The detection rate was 1: 3165 (1:2727 if maternal conditions were also included). There were 23 newborns affected with organic acidemias (incidence: 1:6565), 23 with fatty acid oxidation disorders (incidence: 1:6565), and 10 with amino acidopathies (incidence 1:17,726). The performance metrics for the screening test were acceptable (sensitivity: 95.59%, specificity: 99.85%, PPV: 20%, FPR: 0.15). Participation in the NBS MS/MS program by hospitals was voluntary, and in 2013, the uptake rate was 71% of the annual births. We hope that newborn screening by MS/MS will become a standard of care for all babies in Singapore. Copyright © 2014 Elsevier Inc. All rights reserved.

  20. Bisphenol A alternatives in thermal paper from the Netherlands, Spain, Sweden and Norway. Screening and potential toxicity.

    PubMed

    Björnsdotter, Maria K; Jonker, Willem; Legradi, Jessica; Kool, Jeroen; Ballesteros-Gómez, Ana

    2017-12-01

    Thermal paper contains potentially toxic additives, such as bisphenol A (BPA), as a common color developer. Because of its known endocrine disrupting effects, structural analogues to BPA, such as bisphenol S (BPS), D-8 and Pergafast 201, have been used as alternatives, but little is known about the presence and toxicological effects of alternatives other than BPS. In this study, thermal paper is screened by direct probe ambient mass spectrometry (rapid pre-screening method not requiring sample preparation) and by liquid chromatography (LC) with high resolution time-of flight (TOF-MS) mass spectrometry. Cash receipts and other thermal paper products (cinema tickets, boarding passes and luggage tags) were analyzed. Besides BPA and BPS, other developers only recently reported (Pergafast 201, D-8) or to the best of our knowledge not reported before (D-90, TGSA, BPS-MAE) were frequently found as well as some related unreported impurities (2,4-BPS that is a BPS related impurity and a TGSA related impurity). To gain some insight into the potential estrogenicity of the detected developers, a selection of extracts was further analyzed using a LC-nanofractionation platform in combination with cell-based bioassay testing. These preliminary results seems to indicate very low or absence of estrogenic activity for Pergafast 201, D-8, D-90, TGSA and BPS-MAE in comparison to BPA and BPS, although further dose-response tests with authentic standards are required to confirm these results. Compounds for which standards were available were also tested for developmental toxicity and neurotoxicity using zebrafish (Danio rerio) embryos. TGSA and D-8 induced similar teratogenic effects as BPA in zebrafish embryos. BPS and 2,4-BPS did not induce any developmental effects but 2,4-BPS did alter the locomotor activity at the tested concentration. Our findings suggest that the alternatives used as alternatives to BPA (except BPS) might not be estrogenic. However, TGSA and D-8 showed abnormal developmental effects similar to BPA. Copyright © 2017 Elsevier B.V. All rights reserved.

  1. A high-sensitivity ultra-high performance liquid chromatography/high-resolution time-of-flight mass spectrometry (UHPLC-HR-TOFMS) method for screening synthetic cannabinoids and other drugs of abuse in urine.

    PubMed

    Sundström, Mira; Pelander, Anna; Angerer, Verena; Hutter, Melanie; Kneisel, Stefan; Ojanperä, Ilkka

    2013-10-01

    The continuing emergence of designer drugs imposes high demands on the scope and sensitivity of toxicological drug screening procedures. An ultra-high performance liquid chromatography/high-resolution time-of-flight mass spectrometry (UHPLC-HR-TOFMS) method was developed for screening and simultaneous confirmation of both designer drugs and other drugs of abuse in urine samples in a single run. The method covered selected synthetic cannabinoids and cathinones, amphetamines, natural cannabinoids, opioids, cocaine and other important drugs of abuse, together with their main urinary metabolites. The database consisted of 277 compounds with molecular formula and exact monoisotopic mass; retention time was included for 192 compounds, and primary and secondary qualifier ion exact mass for 191 and 95 compounds, respectively. Following a solid-phase extraction, separation was performed by UHPLC and mass analysis by HR-TOFMS. MS, and broad-band collision-induced dissociation data were acquired at m/z range 50-700. Compound identification was based on a reverse database search with acceptance criteria for retention time, precursor ion mass accuracy, isotopic pattern and abundance of qualifier ions. Mass resolving power in spiked urine samples was on average FWHM 23,500 and mass accuracy 0.3 mDa. The mean and median cut-off concentrations determined for 75 compounds were 4.2 and 1 ng/mL, respectively. The range of cut-off concentrations for synthetic cannabinoids was 0.2-60 ng/mL and for cathinones 0.7-15 ng/mL. The method proved to combine high sensitivity and a wide scope in a manner not previously reported in drugs of abuse screening. The method's feasibility was demonstrated with 50 authentic urine samples.

  2. Relationship between echocardiographic LV mass and ECG based left ventricular voltages in an adolescent population: related or random?

    PubMed

    Czosek, Richard J; Cnota, James F; Knilans, Timothy K; Pratt, Jesse; Guerrier, Karine; Anderson, Jeffrey B

    2014-09-01

    In attempts to detect diseases that may place adolescents at risk for sudden death, some have advocated for population-based screening. Controversy exists over electrocardiography (ECG) screening due to the lack of specificity, cost, and detrimental effects of false positive or extraneous outcomes. Analyze the relationship between precordial lead voltage on ECG and left ventricle (LV) mass by echocardiogram in adolescent athletes. Retrospective cohort analysis of a prospectively obtained population of self-identified adolescent athletes during sports screening with ECG and echocardiogram. Correlation between ECG LV voltages (R wave in V6 [RV6] and S wave in lead V1 [SV1]) was compared to echocardiogram-based measurements of left ventricular mass. Potential effects on ECG voltages by body anthropometrics, including weight, body mass index (BMI), and body surface area were analyzed, and ECG voltages indexed to BMI were compared to LV mass indices to analyze for improved correlation. A total of 659 adolescents enrolled in this study (64% male). The mean age was 15.4 years (14-18). The correlations between LV mass and RV6, SV1, and RV6 + SV1 were all less than 0.20. The false positive rate for abnormal voltages was relatively high (5.5%) but improved if abnormal voltages in both RV6 and SV1 were mandated simultaneously (0%). Indexing ECG voltages to BMI significantly improved correlation to LV mass, though false positive findings were increased (12.9%). There is poor correlation between ECG precordial voltages and echocardiographic LV mass. This relationship is modified by BMI. This finding may contribute to the poor ECG screening characteristics. ©2014 Wiley Periodicals, Inc.

  3. Novel simple and practical nutritional screening tool for cancer inpatients: a pilot study.

    PubMed

    Zekri, Jamal; Morganti, Julie; Rizvi, Azhar; Sadiq, Bakr Bin; Kerr, Ian; Aslam, Mohamed

    2014-05-01

    There is lack of consensus on how nutritional screening and intervention should be provided to cancer patients. Nutritional screening and support of cancer patients are not well established in the Middle East. We report our systematic and practical experience led by a qualified specialist dietician in a cancer inpatient setting, using a novel nutritional screening tool. Ninety-seven consecutive inpatients underwent nutritional screening and categorised into three nutritional risk groups based on oral intake, gastrointestinal symptoms, body mass index (BMI) and weight loss. Nutritional support was introduced accordingly. Statistical tests used included ANOVA, Bonferroni post hoc, chi-square and log rank tests. Median age was 48 (19-87)years. Patients were categorised into three nutritional risk groups: 55 % low, 37 % intermediate and 8 % high. Nutritional intervention was introduced for 36 % of these patients. Individually, weight, BMI, oral intake, serum albumin on admission and weight loss significantly affected nutritional risk and nutritional intervention (all significant P values). Eighty-seven, 60 and 55 % of patients admitted for chemotherapy, febrile neutropenia and other reasons, respectively, did not require specific nutritional intervention. There was a statistically significant relationship between nutritional risk and nutritional intervention (P=0.005). Significantly more patients were alive at 3 months in low (91 %) than intermediate (75 %) than high (37 %)-risk groups. About a third of cancer inpatients require nutritional intervention. The adopted nutritional risk assessment tool is simple and practical. The validity of this tool is supported by its significant relation with known individual nutritional risk factors. This should be confirmed in larger prospective study and comparing this new tool with other established ones.

  4. Rapid screening of bioactive compounds from natural products by integrating 5-channel parallel chromatography coupled with on-line mass spectrometry and microplate based assays.

    PubMed

    Zhang, Yufeng; Xiao, Shun; Sun, Lijuan; Ge, Zhiwei; Fang, Fengkai; Zhang, Wen; Wang, Yi; Cheng, Yiyu

    2013-05-13

    A high throughput method was developed for rapid screening and identification of bioactive compounds from traditional Chinese medicine, marine products and other natural products. The system, integrated with five-channel chromatographic separation and dual UV-MS detection, is compatible with in vitro 96-well microplate based bioassays. The stability and applicability of the proposed method was validated by testing radical scavenging capability of a mixture of seven known compounds (rutin, dihydroquercetin, salvianolic acid A, salvianolic acid B, glycyrrhizic acid, rubescensin A and tangeretin). Moreover, the proposed method was successfully applied to the crude extracts of traditional Chinese medicine and a marine sponge from which 12 bioactive compounds were screened and characterized based on their anti-oxidative or anti-tumor activities. In particular, two diterpenoid derivatives, agelasine B and (-)-agelasine D, were identified for the first time as anti-tumor compounds from the sponge Agelas mauritiana, showing a considerable activity toward MCF-7 cells (IC50 values of 7.84±0.65 and 10.48±0.84 μM, respectively). Our findings suggested that the integrated system of 5-channel parallel chromatography coupled with on-line mass spectrometry and microplate based assays can be a versatile and high efficient approach for the discovery of active compounds from natural products. Copyright © 2013 Elsevier B.V. All rights reserved.

  5. Understanding Pediatricians' Views toward School-Based BMI Screening in Massachusetts: A Pilot Study

    ERIC Educational Resources Information Center

    Pietras, Stefanie A.; Rhodes, Erinn T.; Meyers, Alan; Goodman, Elizabeth

    2012-01-01

    Background: Massachusetts (MA) mandated body mass index (BMI) screening in schools in 2010. However, little is known about pediatricians' views on school-based screening or how the pediatricians' perspectives might affect the school-based screening process. We assessed MA pediatricians' knowledge, attitudes, beliefs, and practices concerning BMI…

  6. Body Mass Index and Cancer Screening in Older American Indian and Alaska Native Men

    ERIC Educational Resources Information Center

    Muus, Kyle J.; Baker-Demaray, Twyla; McDonald, Leander R.; Ludtke, Richard L.; Allery, Alan J.; Bogart, T. Andy; Goldberg, Jack; Ramsey, Scott D.; Buchwald, Dedra S.

    2009-01-01

    Context: Regular screenings are important for reducing cancer morbidity and mortality. There are several barriers to receiving timely cancer screening, including overweight/obesity. No study has examined the relationship between overweight/obesity and cancer screening among American Indian/Alaska Natives (AI/ANs). Purpose: To describe the…

  7. Pilot production and testing of high efficiency wraparound contact solar cells

    NASA Technical Reports Server (NTRS)

    Gillanders, M.

    1981-01-01

    Modifications were made to the process sequence until a device capable of high performance and satisfactory processing yields could be fabricated on a production line. Pilot production resulted in a 2 x 4 cm screen printed dielectric wraparound contact solar cell with average 28 C, Air Mass Zero (AMO) conversion efficiencies of 14.2% and reasonable process yields. This high performance was obtained with two different back contact configurations, making the device acceptable for many applications.

  8. Waist-to-Height Ratio: a simple, effective and practical screening tool for childhood obesity and metabolic syndrome.

    PubMed

    Zhou, Dan; Yang, Min; Yuan, Zhe-Ping; Zhang, Dan-Dan; Liang, Li; Wang, Chun-Lin; Zhang, Shuai; Zhu, Hong-Hong; Lai, Mao-De; Zhu, Yi-Min

    2014-10-01

    This study aimed to evaluate the diagnostic value of Waist-to-Height Ratio in early detection of obesity and metabolic syndrome in Chinese children and adolescents. A cross-sectional study was conducted in six cities in China in 2010 with 16,914 children and adolescents aged 7-17 years. Participants were randomly divided into the training and testing sets. Diagnostic values were estimated using sensitivity, specificity and areas under receiver operating characteristic curves. The coefficients of variation of Waist-to-Height Ratio among age groups were lower than that of body mass index and waist circumstance. The area under receiver operating characteristic curve of Waist-to-Height Ratio was 0.968 in boys and 0.949 in girls for general obesity evaluation, and 0.983 in boys and 0.984 in girls for central obesity. The optimal cut-offs of Waist-to-Height Ratio were 0.47 in boys and 0.45 in girls in the training set and validated in the testing set. For metabolic syndrome evaluation, the sensitivity and specificity were 0.858 and 0.825 in boys, 0.864 and 0.812 in girls under the suggested cut-offs. Waist-to-Height Ratio was a simple, effective and practical tool for mass screening childhood obesity and metabolic syndrome in China. It will have potential values in public health practice. Copyright © 2014 Elsevier Inc. All rights reserved.

  9. Can Screening and Confirmatory Testing in the Management of Patients with Primary Aldosteronism be Improved?

    PubMed

    Stowasser, Michael; Ahmed, Ashraf; Guo, Zeng; Wolley, Martin; Ungerer, Jacobus; McWhinney, Brett; Poglitsch, Marko; Gordon, Richard

    2017-12-01

    Widespread application of the plasma aldosterone/renin ratio (ARR) as a screening test has led to the recognition that primary aldosteronism (PA) is the most common specifically treatable and potentially curable form of hypertension, accounting for 5-10% of patients. Maximal detection requires accurate diagnostic approaches and awareness and control of factors that confound results, including most antihypertensives, posture, time of day, dietary salt, and plasma potassium. Recent studies have revealed potential for false positives in patients on beta-adrenoceptor blockers, and, when direct renin concentration (but not plasma renin activity) is used to measure renin, in women during the luteal phase of the menstrual cycle or receiving estrogen-containing contraceptives or hormonal replacement therapy. In addition to verapamil slow release, hydralazine and prazosin, moxonidine has minimal effects on the ARR and can be used to control hypertension during work-up. Fludrocortisone suppression testing, while probably the most reliable means of definitively confirming or excluding PA, is time consuming and expensive, requiring a five day inpatient stay. A novel approach, upright (seated) saline infusion suppression testing (SST), has shown excellent reliability with much greater sensitivity than conventional recumbent SST in a recent pilot study, and requires only a day visit. Accurate measurement of aldosterone is essential for each step of PA workup: introduction of new, highly reliable high-throughput mass spectrometric methods into clinical practice has represented a major advance. In response to concerns raised about accuracy of renin assays, new mass spectrometric methods for measuring angiotensin II are currently being assessed in the clinical setting. © Georg Thieme Verlag KG Stuttgart · New York.

  10. The current preference for the immuno-analytical ELISA method for quantitation of steroid hormones (endocrine disruptor compounds) in wastewater in South Africa.

    PubMed

    Manickum, Thavrin; John, Wilson

    2015-07-01

    The availability of national test centers to offer a routine service for analysis and quantitation of some selected steroid hormones [natural estrogens (17-β-estradiol, E2; estrone, E1; estriol, E3), synthetic estrogen (17-α-ethinylestradiol, EE2), androgen (testosterone), and progestogen (progesterone)] in wastewater matrix was investigated; corresponding internationally used chemical- and immuno-analytical test methods were reviewed. The enzyme-linked immunosorbent assay (ELISA) (immuno-analytical technique) was also assessed for its suitability as a routine test method to quantitate the levels of these hormones at a sewage/wastewater treatment plant (WTP) (Darvill, Pietermaritzburg, South Africa), over a 2-year period. The method performance and other relevant characteristics of the immuno-analytical ELISA method were compared to the conventional chemical-analytical methodology, like gas/liquid chromatography-mass spectrometry (GC/LC-MS), and GC-LC/tandem mass spectrometry (MSMS), for quantitation of the steroid hormones in wastewater and environmental waters. The national immuno-analytical ELISA technique was found to be sensitive (LOQ 5 ng/L, LOD 0.2-5 ng/L), accurate (mean recovery 96%), precise (RSD 7-10%), and cost-effective for screening and quantitation of these steroid hormones in wastewater and environmental water matrix. A survey of the most current international literature indicates a fairly equal use of the LC-MS/MS, GC-MS/MS (chemical-analytical), and ELISA (immuno-analytical) test methods for screening and quantitation of the target steroid hormones in both water and wastewater matrix. Internationally, the observed sensitivity, based on LOQ (ng/L), for the steroid estrogens E1, E2, EE2, is, in decreasing order: LC-MSMS (0.08-9.54) > GC-MS (1) > ELISA (5) (chemical-analytical > immuno-analytical). At the national level, the routine, unoptimized chemical-analytical LC-MSMS method was found to lack the required sensitivity for meeting environmental requirements for steroid hormone quantitation. Further optimization of the sensitivity of the chemical-analytical LC-tandem mass spectrometry methods, especially for wastewater screening, in South Africa is required. Risk assessment studies showed that it was not practical to propose standards or allowable limits for the steroid estrogens E1, E2, EE2, and E3; the use of predicted-no-effect concentration values of the steroid estrogens appears to be appropriate for use in their risk assessment in relation to aquatic organisms. For raw water sources, drinking water, raw and treated wastewater, the use of bioassays, with trigger values, is a useful screening tool option to decide whether further examination of specific endocrine activity may be warranted, or whether concentrations of such activity are of low priority, with respect to health concerns in the human population. The achievement of improved quantitation limits for immuno-analytical methods, like ELISA, used for compound quantitation, and standardization of the method for measuring E2 equivalents (EEQs) used for biological activity (endocrine: e.g., estrogenic) are some areas for future EDC research.

  11. Computer-aided diagnosis workstation and database system for chest diagnosis based on multi-helical CT images

    NASA Astrophysics Data System (ADS)

    Satoh, Hitoshi; Niki, Noboru; Mori, Kiyoshi; Eguchi, Kenji; Kaneko, Masahiro; Kakinuma, Ryutarou; Moriyama, Noriyuki; Ohmatsu, Hironobu; Masuda, Hideo; Machida, Suguru; Sasagawa, Michizou

    2006-03-01

    Multi-helical CT scanner advanced remarkably at the speed at which the chest CT images were acquired for mass screening. Mass screening based on multi-helical CT images requires a considerable number of images to be read. It is this time-consuming step that makes the use of helical CT for mass screening impractical at present. To overcome this problem, we have provided diagnostic assistance methods to medical screening specialists by developing a lung cancer screening algorithm that automatically detects suspected lung cancers in helical CT images and a coronary artery calcification screening algorithm that automatically detects suspected coronary artery calcification. We also have developed electronic medical recording system and prototype internet system for the community health in two or more regions by using the Virtual Private Network router and Biometric fingerprint authentication system and Biometric face authentication system for safety of medical information. Based on these diagnostic assistance methods, we have now developed a new computer-aided workstation and database that can display suspected lesions three-dimensionally in a short time. This paper describes basic studies that have been conducted to evaluate this new system. The results of this study indicate that our computer-aided diagnosis workstation and network system can increase diagnostic speed, diagnostic accuracy and safety of medical information.

  12. A strategy for screening and identifying mycotoxins in herbal medicine using ultra-performance liquid chromatography with tandem quadrupole time-of-flight mass spectrometry.

    PubMed

    Fang, Lian-xiang; Xiong, Ai-zhen; Wang, Rui; Ji, Shen; Yang, Li; Wang, Zheng-tao

    2013-09-01

    The objective of this study was to develop an effective strategy for screening and identifying mycotoxins in herbal medicine (HM). Here, Imperatae Rhizoma, a commonly used Chinese herb, was selected as a model HM. A crude drug contaminated with fungi was analyzed by comparing with uncontaminated ones. Ultra-performance LC coupled to tandem quadrupole TOF-MS (UPLC-Q-TOF-MS) with collision energy function was applied to analyze different samples from Imperatae Rhizoma. Then, MarkerLynx(TM) software was employed to screen the excess components in analytes, compared with control samples, and those selected markers were likely to be the metabolites of fungi. Furthermore, each of the accurate masses of the markers obtained from MarkerLynx(TM) was then searched in a mycotoxins/fungal metabolites database established in advance. The molecular formulas with relative mass error between the measured and theoretical mass within 5 ppm were chosen and then applied to MassFragment(TM) analysis for further confirmation of their structures. With the use of this approach, five mycotoxins that have never been reported in HM were identified in contaminated Imperatae Rhizoma. The results demonstrate the potential of UPLC-Q-TOF-MS coupled with the MarkerLynx(TM) software and MassFragment(TM) tool as an efficient and convenient method to screen and identify mycotoxins in herbal materials and aid in the quality control of HM. © 2013 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  13. Cancer Screening Test Use - United States, 2015.

    PubMed

    White, Arica; Thompson, Trevor D; White, Mary C; Sabatino, Susan A; de Moor, Janet; Doria-Rose, Paul V; Geiger, Ann M; Richardson, Lisa C

    2017-03-03

    Healthy People 2020 (HP2020) includes objectives to increase screening for breast, cervical, and colorectal cancer (1) as recommended by the U.S. Preventive Services Task Force (USPSTF).* Progress toward meeting these objectives is monitored by measuring cancer screening test use against national targets using data from the National Health Interview Survey (NHIS) (1). Analysis of 2015 NHIS data indicated that screening test use remains substantially below HP2020 targets for selected cancer screening tests. Although colorectal cancer screening test use increased from 2000 to 2015, no improvements in test use were observed for breast and cervical cancer screening. Disparities exist in screening test use by race/ethnicity, socioeconomic status, and health care access indicators. Increased measures to implement evidence-based interventions and conduct targeted outreach are needed if the HP2020 targets for cancer screening are to be achieved and the disparities in screening test use are to be reduced.

  14. Segmentation algorithm of colon based on multi-slice CT colonography

    NASA Astrophysics Data System (ADS)

    Hu, Yizhong; Ahamed, Mohammed Shabbir; Takahashi, Eiji; Suzuki, Hidenobu; Kawata, Yoshiki; Niki, Noboru; Suzuki, Masahiro; Iinuma, Gen; Moriyama, Noriyuki

    2012-02-01

    CT colonography is a radiology test that looks at people's large intestines(colon). CT colonography can screen many options of colon cancer. This test is used to detect polyps or cancers of the colon. CT colonography is safe and reliable. It can be used if people are too sick to undergo other forms of colon cancer screening. In our research, we proposed a method for automatic segmentation of the colon from abdominal computed Tomography (CT) images. Our multistage detection method extracted colon and spited colon into different parts according to the colon anatomy information. We found that among the five segmented parts of the colon, sigmoid (20%) and rectum (50%) are more sensitive toward polyps and masses than the other three parts. Our research focused on detecting the colon by the individual diagnosis of sigmoid and rectum. We think it would make the rapid and easy diagnosis of colon in its earlier stage and help doctors for analysis of correct position of each part and detect the colon rectal cancer much easier.

  15. Child's Weight Status and Parent's Response to a School-Based Body Mass Index Screening and Parent Notification Program

    ERIC Educational Resources Information Center

    Lee, Jiwoo; Kubik, Martha Y.

    2015-01-01

    This study examined the response of parents of elementary school-aged children to a school-based body mass index (BMI) screening and parent notification program conducted in one Minnesota school district in 2010-2011 and whether parent's response was moderated by child's weight status. Randomly selected parents (N = 122) of second- and…

  16. Headspace screening of fluid obtained from the gut during colonoscopy and breath analysis by proton transfer reaction-mass spectrometry: A novel approach in the diagnosis of gastro-intestinal diseases

    NASA Astrophysics Data System (ADS)

    Lechner, M.; Colvin, H. P.; Ginzel, C.; Lirk, P.; Rieder, J.; Tilg, H.

    2005-05-01

    Background: The diagnosis of many gastro-intestinal diseases is difficult and can often be confirmed only by using invasive diagnostic means. In contrast, the headspace screening of fluid obtained from the gut during colonoscopy and the analysis of exhaled air may be a novel approach for the diagnosis of these diseases.Materials and methods: The screening was performed by using proton transfer reaction-mass spectrometry (PTR-MS) which allows rapid and sensitive measurement. Fluid samples obtained from the gut during colonoscopy were collected from 76 and breath samples from 70 subjects. Mass spectra of healthy controls were created. Afterwards these spectra were compared with those of patients suffering from inflammatory bowel diseases (IBD; Crohn's disease and ulcerative colitis; n = 10) and irritable bowel syndrome (IBS; n = 7).Results: Significant differences in the mass spectra could be observed both in the headspace of the fluid and in the exhaled air comparing patients with healthy controls.Conclusions: This study is the first describing headspace screening of fluid obtained from the gut during colonoscopy, possibly presenting a novel diagnostic tool in the differential diagnosis of gastro-intestinal diseases.

  17. Current applications of high-resolution mass spectrometry for the analysis of new psychoactive substances: a critical review.

    PubMed

    Pasin, Daniel; Cawley, Adam; Bidny, Sergei; Fu, Shanlin

    2017-10-01

    The proliferation of new psychoactive substances (NPS) in recent years has resulted in the development of numerous analytical methods for the detection and identification of known and unknown NPS derivatives. High-resolution mass spectrometry (HRMS) has been identified as the method of choice for broad screening of NPS in a wide range of analytical contexts because of its ability to measure accurate masses using data-independent acquisition (DIA) techniques. Additionally, it has shown promise for non-targeted screening strategies that have been developed in order to detect and identify novel analogues without the need for certified reference materials (CRMs) or comprehensive mass spectral libraries. This paper reviews the applications of HRMS for the analysis of NPS in forensic drug chemistry and analytical toxicology. It provides an overview of the sample preparation procedures in addition to data acquisition, instrumental analysis, and data processing techniques. Furthermore, it gives an overview of the current state of non-targeted screening strategies with discussion on future directions and perspectives of this technique. Graphical Abstract Missing the bullseye - a graphical respresentation of non-targeted screening. Image courtesy of Christian Alonzo.

  18. Data-Independent Mass Spectrometry Approach for Screening and Identification of DNA Adducts.

    PubMed

    Guo, Jingshu; Villalta, Peter W; Turesky, Robert J

    2017-11-07

    Long-term exposures to environmental toxicants and endogenous electrophiles are causative factors for human diseases including cancer. DNA adducts reflect the internal exposure to genotoxicants and can serve as biomarkers for risk assessment. Liquid chromatography-multistage mass spectrometry (LC-MS n ) is the most common method for biomonitoring DNA adducts, generally targeting single exposures and measuring up to several adducts. However, the data often provide limited evidence for a role of a chemical in the etiology of cancer. An "untargeted" method is required that captures global exposures to chemicals, by simultaneously detecting their DNA adducts in the genome; some of which may induce cancer-causing mutations. We established a wide selected ion monitoring tandem mass spectrometry (wide-SIM/MS 2 ) screening method utilizing ultraperformance-LC nanoelectrospray ionization Orbitrap MS n with online trapping to enrich bulky, nonpolar adducts. Wide-SIM scan events are followed by MS 2 scans to screen for modified nucleosides by coeluting peaks containing precursor and fragment ions differing by -116.0473 Da, attributed to the neutral loss of deoxyribose. Wide-SIM/MS 2 was shown to be superior in sensitivity, specificity, and breadth of adduct coverage to other tested adductomic methods with detection possible at adduct levels as low as 4 per 10 9 nucleotides. Wide-SIM/MS 2 data can be analyzed in a "targeted" fashion by generation of extracted ion chromatograms or in an "untargeted" fashion where a chromatographic peak-picking algorithm can be used to detect putative DNA adducts. Wide-SIM/MS 2 successfully detected DNA adducts, derived from chemicals in the diet and traditional medicines and from lipid peroxidation products, in human prostate and renal specimens.

  19. Rapid analysis of the skin irritant p-phenylenediamine (PPD) in henna products using atmospheric solids analysis probe mass spectrometry.

    PubMed

    Chen, Weiyang; Nkosi, Thobile A N; Combrinck, Sandra; Viljoen, Alvaro M; Cartwright-Jones, Catherine

    2016-09-05

    Henna (Lawsonia inermis) is applied to stain keratin, present in hair, skin and fingernails, a red-orange or rust colour. Producers of temporary tattoos mix the aromatic amine compound, para-phenylenediamine (PPD) into natural henna to create 'black henna' that rapidly stains the skin black. However, PPD may cause severe delayed hypersensitivity reactions following skin contact. This study proposes a rapid direct-analysis method to detect and identify PPD using an atmospheric solids analysis probe (ASAP) coupled to a Q-ToF mass spectrometer (MS). Since laborious, multistep methods of analysis to determine PPD are undesirable, due to the instability of the compound in solution, a screening method involving no sample preparation steps was developed. Experiments were carried out to optimise the corona current, sample cone voltage, source temperature, and desolvation gas temperature to determine ideal ASAP-Q-ToF-MS analysing conditions. Eleven of the 109 henna samples, originating from various countries, tested positive for PPD when henna products were screened using ASAP-MS, without any form of sample preparation other than grinding. Ultra-performance liquid chromatography electrospray ionisation-mass spectrometry (UPLC-Q-ToF-MS) was subsequently used to confirm the results from ASAP and to determine the concentrations of PPD in henna products. The allergen was detected in the same eleven samples, with concentrations ranging from 0.05-4.21% (w/w). It can be concluded that the sensitivity of the ASAP-MS technique is sufficient (limit of detection=0.025% w/w) to allow screening of henna samples for the presence of PPD. This relatively new technique can be applied to commercial products without extraction, sample treatment or chromatographic separation. Copyright © 2016 Elsevier B.V. All rights reserved.

  20. A Smartphone App to Screen for HIV-Related Neurocognitive Impairment.

    PubMed

    Robbins, Reuben N; Brown, Henry; Ehlers, Andries; Joska, John A; Thomas, Kevin G F; Burgess, Rhonda; Byrd, Desiree; Morgello, Susan

    2014-02-01

    Neurocognitive Impairment (NCI) is one of the most common complications of HIV-infection, and has serious medical and functional consequences. However, screening for it is not routine and NCI often goes undiagnosed. Screening for NCI in HIV disease faces numerous challenges, such as limited screening tests, the need for specialized equipment and apparatuses, and highly trained personnel to administer, score and interpret screening tests. To address these challenges, we developed a novel smartphone-based screening tool, NeuroScreen , to detect HIV-related NCI that includes an easy-to-use graphical user interface with ten highly automated neuropsychological tests. To examine NeuroScreen's : 1) acceptability among patients and different potential users; 2) test construct and criterion validity; and 3) sensitivity and specificity to detect NCI. Fifty HIV+ individuals were administered a gold-standard neuropsychological test battery, designed to detect HIV-related NCI, and NeuroScreen . HIV+ test participants and eight potential provider-users of NeuroScreen were asked about its acceptability. There was a high level of acceptability of NeuroScreen by patients and potential provider-users. Moderate to high correlations between individual NeuroScreen tests and paper-and-pencil tests assessing the same cognitive domains were observed. NeuroScreen also demonstrated high sensitivity to detect NCI. NeuroScreen, a highly automated, easy-to-use smartphone-based screening test to detect NCI among HIV patients and usable by a range of healthcare personnel could help make routine screening for HIV-related NCI feasible. While NeuroScreen demonstrated robust psychometric properties and acceptability, further testing with larger and less neurocognitively impaired samples is warranted.

  1. Simultaneous Screening and Quantification of Basic, Neutral and Acidic Drugs in Blood Using UPLC-QTOF-MS.

    PubMed

    Bidny, Sergei; Gago, Kim; Chung, Phuong; Albertyn, Desdemona; Pasin, Daniel

    2017-04-01

    An analytical method using ultra performance liquid chromatography (UPLC) quadrupole time-of-flight mass spectrometry (QTOF-MS) was developed and validated for the targeted toxicological screening and quantification of commonly used pharmaceuticals and drugs of abuse in postmortem blood using 100 µL sample. It screens for more than 185 drugs and metabolites and quantifies more than 90 drugs. The selected compounds include classes of pharmaceuticals and drugs of abuse such as: antidepressants, antipsychotics, analgesics (including narcotic analgesics), anti-inflammatory drugs, benzodiazepines, beta-blockers, amphetamines, new psychoactive substances (NPS), cocaine and metabolites. Compounds were extracted into acetonitrile using a salting-out assisted liquid-liquid extraction (SALLE) procedure. The extracts were analyzed using a Waters ACQUITY UPLC coupled with a XEVO QTOF mass spectrometer. Separation of the analytes was achieved by gradient elution using Waters ACQUITY HSS C18 column (2.1 mm x 150 mm, 1.8 μm). The mass spectrometer was operated in both positive and negative electrospray ionization modes. The high-resolution mass spectrometry (HRMS) data was acquired using a patented Waters MSE acquisition mode which collected low and high energy spectra alternatively during the same acquisition. Positive identification of target analytes was based on accurate mass measurements of the molecular ion, product ion, peak area ratio and retention times. Calibration curves were linear over the concentration range 0.05-2 mg/L for basic and neutral analytes and 0.1-6 mg/L for acidic analytes with the correlation coefficients (r2) > 0.96 for most analytes. The limits of detection (LOD) were between 0.001-0.05 mg/L for all analytes. Good recoveries were achieved ranging from 80% to 100% for most analytes using the SALLE method. The method was validated for sensitivity, selectivity, accuracy, precision, stability, carryover and matrix effects. The developed method was tested on a number of authentic forensic samples producing consistent results that correlated with results obtained from other validated methods. © The Author 2016. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

  2. Screening of environmental contaminants in honey bee wax comb using gas chromatography-high-resolution time-of-flight mass spectrometry.

    PubMed

    Gómez-Ramos, M M; García-Valcárcel, A I; Tadeo, J L; Fernández-Alba, A R; Hernando, M D

    2016-03-01

    This study reports an analytical approach intended to be used for investigation of non-targeted environmental contaminants and to characterize the organic pollution pattern of bee wax comb samples. The method comprises a generic extraction followed by detection with gas chromatography coupled to high-resolution time-of-flight mass spectrometry (GC-TOF-MS), operated in electron impact ionization (EI) mode. The screening approach for the investigation of non-targeted contaminants consisted of initial peak detection by deconvolution and matching the first-stage mass spectra EI-MS(1) with a nominal mass spectral library. To gain further confidence in the structural characterization of the contaminants under investigation, the molecular formula of representative ions (molecular ion when present in the EI spectrum) and, for at least other two fragment ions, was provided for those with an accurate mass scoring (mass error < 5 ppm). This methodology was applied for screening environmental contaminants in 50 samples of bee wax comb. This approach has allowed the tentative identification of some GC-amenable contaminants belonging to different chemical groups, among them, phthalates and polycyclic aromatic hydrocarbons (PAHs), along with residues of veterinary treatments used in apiculture.

  3. Diagnosis of glutaric aciduria type 1 by measuring 3-hydroxyglutaric acid in dried urine spots by liquid chromatography tandem mass spectrometry.

    PubMed

    Al-Dirbashi, Osama Y; Kölker, Stefan; Ng, Dione; Fisher, Lawrence; Rupar, Tony; Lepage, Nathalie; Rashed, Mohamed S; Santa, Tomofumi; Goodman, Stephen I; Geraghty, Michael T; Zschocke, Johannes; Christensen, Ernst; Hoffmann, Georg F; Chakraborty, Pranesh

    2011-02-01

    Accumulation of glutaric acid (GA) and 3-hydroxyglutaric acid (3HGA) in body fluids is the biochemical hallmark of type 1 glutaric aciduria (GA1), a disorder characterized by acute striatal degeneration and a subsequent dystonia. To date, methods for quantification of 3HGA are mainly based on stable isotope dilution gas chromatography mass spectrometry (GC-MS) and require extensive sample preparation. Here we describe a simple liquid chromatography tandem MS (LC-MS/MS) method to quantify this important metabolite in dried urine spots (DUS). This method is based on derivatization with 4-[2-(N,N-dimethylamino)ethylaminosulfonyl]-7-(2-aminoethylamino)-2,1,3-benzoxadiazole (DAABD-AE). Derivatization was adopted to improve the chromatographic and mass spectrometric properties of the studied analytes. Derivatization was performed directly on a 3.2-mm disc of DUS as a sample without extraction. Sample mixture was heated at 60°C for 45 min, and 5 μl of the reaction solution was analyzed by LC-MS/MS. Reference ranges obtained were in excellent agreement with the literature. The method was applied retrospectively for the analysis of DUS samples from established low- and high-excreter GA1 patients as well as controls (n = 100). Comparison of results obtained versus those obtained by GC-MS was satisfactory (n = 14). In populations with a high risk of GA1, this approach will be useful as a primary screening method for high- or low-excreter variants. In these populations, however, DUS analysis should not be implemented before completing a parallel comparative study with the standard screening method (i.e., molecular testing). In addition, follow-up DUS GA and 3HGA testing of babies with elevated dried blood spot C5DC acylcarnitines will be useful as a first-tier diagnostic test, thus reducing the number of cases requiring enzymatic and molecular analyses to establish or refute the diagnosis of GA1.

  4. [Rapid screening the alkaloids of poppy shell in hot pot condiment, beef noodle soup and seasoning by direct analysis in real time-tandem mass spectrometry].

    PubMed

    Zhang, Baile; Gao, Lihong; Xie, Yingshuang; Zhou, Wei; Chen, Xiaofeng; Lei, Chunni; Zhang, Huan

    2017-07-08

    A direct analysis in real time tandem mass spectrometry (DART-MS/MS) method was established for quickly screening five illegally added alkaloids of poppy shell from the hot pot condiment, beef noodle soup and seasoning. The samples were extracted and purified by acetonitrile, and then injected under the conditions of ionization temperature of 300℃, grid electrode voltage of 150 V and sampling rate of 0.8 mm/s using DART in the positive ion mode. The determination was conducted by tandem mass spectrometry in positive ESI mode under multiple reaction monitoring (MRM) mode. The method is simple and rapid, and can meet the requirement of rapid screening and analysis of large quantities of samples.

  5. Dioxins in beef samples from Mexico using a low resolution GC/MS screening method.

    PubMed

    Naccha, Lidia; Alanis, Guadalupe; Torres, Anabel; Abad, Esteban; Ábalos, Manuela; Rivera, Josep; Heyer, Lorenzo; Morales, Alberto; Waksman, Noemí

    2010-01-01

    Dioxins in beef were quantified by high resolution gas chromatography coupled to low-resolution mass spectrometry (GC/LRMS). The analyses were performed according to the minimum requirements described in the USEPA 1613 method with some minor modifications. Levels found in the samples were in the range 1.02-8.04 pg WHO-TEQ PCDDs/PCDFs g(-1) fat. For comparison purposes, the maximum level allowed by the European Union is 3 pg WHO-TEQ PCDDs/PCDFs g(-1) fat, and some of these samples surpassed the above-mentioned limit and can be considered as contaminated food. The results confirm that a preliminary screening of dioxins in beef can be performed by GC/LRMS. As far as we know, this is the first report of dioxins in beef in Mexico. After the appropriated tests, the applied methodology could be considered as an alternative screening method for the analysis of PCDD/Fs in other food products.

  6. Identification of patients with nasopharyngeal carcinoma by serum protein profiling using surface-enhanced laser desorption/ionization time-of-flight mass spectrometry.

    PubMed

    Zhu, Xiao-Dong; Su, Fang; Liang, Zhong-Guo; Li, Ling; Qu, Song; Liang, Xia; Wang, Qi; Liang, Shi-Xiong; Chen, Long

    2014-08-01

    As diagnosis of nasopharyngeal carcinoma at an early disease stage is important, we attempted to distinguish between patients with nasopharyngeal carcinoma and noncancer controls by using serum protein profiles. Surface-enhanced laser desorption/ionization time-of-flight mass spectrometry and CM10 protein chip were used to detect the serum proteomic patterns of 65 patients with nasopharyngeal carcinoma before radiotherapy and 93 noncancer controls. Proteomic spectra of serum samples from 50 nasopharyngeal carcinoma patients and 60 noncancer controls were used as a training set. The validity of the classification tree was then challenged with a blind test set which included another 15 patients with nasopharyngeal carcinoma and 33 noncancer controls. Biomarker Wizard 3.01 and Biomarker Pattern 5.01 were used in combination to analyze the data and to develop diagnostic models. 21 protein peaks were significantly different between nasopharyngeal carcinoma and controls. 4 mass peaks (M4182, M5343, M5913 and M8702 mass/charge ratio) were chosen automatically to construct a classification tree. The classification tree correctly determined 93.8 % (45/48) of the test samples with 93.3 % (14/15) of the nasopharyngeal carcinoma samples and 93.9 % (31/33) of the noncancer samples. Using a combination of serum protein profiles and Epstein-Barr viral capsid antigen immunoglobulin A antibody tests, the diagnostic sensitivity and specificity were increased to 100 and 97 %, respectively. Surface-enhanced laser desorption/ionization time-of-flight mass spectrometry could correctly distinguish nasopharyngeal carcinoma from noncancer individuals and showed great potential for the development of a screening test for the detection of nasopharyngeal carcinoma.

  7. Metabolism of clofibric acid in zebrafish embryos (Danio rerio) as determined by liquid chromatography-high resolution-mass spectrometry.

    PubMed

    Brox, Stephan; Seiwert, Bettina; Haase, Nora; Küster, Eberhard; Reemtsma, Thorsten

    2016-01-01

    The zebrafish embryo (ZFE) is increasingly used in ecotoxicology research but detailed knowledge of its metabolic potential is still limited. This study focuses on the xenobiotic metabolism of ZFE at different life-stages using the pharmaceutical compound clofibric acid as study compound. Liquid chromatography with quadrupole-time-of-flight mass spectrometry (LC-QToF-MS) is used to detect and to identify the transformation products (TPs). In screening experiments, a total of 18 TPs was detected and structure proposals were elaborated for 17 TPs, formed by phase I and phase II metabolism. Biotransformation of clofibric acid by the ZFE involves conjugation with sulfate or glucuronic acid, and, reported here for the first time, with carnitine, taurine, and aminomethanesulfonic acid. Further yet unknown cyclization products were identified using non-target screening that may represent a new detoxification pathway. Sulfate containing TPs occurred already after 3h of exposure (7hpf), and from 48h of exposure (52hpf) onwards, all TPs were detected. The detection of these TPs indicates the activity of phase I and phase II enzymes already at early life-stages. Additionally, the excretion of one TP into the exposure medium was observed. The results of this study outline the high metabolic potential of the ZFE with respect to the transformation of xenobiotics. Similarities but also differences to other test systems were observed. Biotransformation of test chemicals in toxicity testing with ZFE may therefore need further consideration. Copyright © 2016 Elsevier Inc. All rights reserved.

  8. Sedentary Behavior Is Independently Related to Fat Mass among Children and Adolescents in South China

    PubMed Central

    Xue, Hongmei; Tian, Guo; Duan, Ruonan; Quan, Liming; Zhao, Li; Yang, Min; Libuda, Lars; Muckelbauer, Rebecca; Cheng, Guo

    2016-01-01

    We aim to explore the independent associations of sedentary behaviors (SB) with body mass distribution among Chinese children. Data on the screen-based sedentary time (television viewing and computer use) and doing homework, physical activities and dietary intake of 1586 Chinese children (50.3% girls) aged 7–15 years were obtained through validated questionnaires. Skin-fold thickness, body height, and weight were measured to calculate percent body fat (%BF), fat mass index (FMI), and fat-free mass index (FFMI). Parental characteristics were collected by questionnaires. Among girls, time of SB (screen time or doing homework) was positively related to %BF, FMI, and FFMI (p < 0.03) after adjusting for maternal overweight, the average annual income of family, moderate-to-vigorous physical activity energy expenditure, and energy intake: Girls in the highest tertile of screen time/homework had 16.7%/23.3% higher relative FMI and 2.9%/2.9% higher relative FFMI than girls in the lowest tertile. Among boys, screen time was positively associated with FFMI (p < 0.003), but not related to %BF and FMI (p > 0.09), while time of doing homework was positively related to %BF and FMI (p = 0.03). Sedentary behaviors might be positively and independently related to fat mass among Chinese children, and were more pronounced in girls. PMID:27792134

  9. Design and Development of an Electrostatic Screen Battery for Emission Control (ESBEC)

    PubMed Central

    Han, Taewon; Mainelis, Gediminas

    2017-01-01

    Current diesel particulate filters (DPFs) can effectively capture the exhaust particles, but they add to engine backpressure and accumulate particles during their operation, which results in the need to regenerate the DPFs by burning off the collected particles periodically. This regeneration results in aerosol emissions, especially in the 10–30 nanometer size range and contributes to ultrafine particle pollution. In this research, we designed and developed a prototype of a novel diesel exhaust control device: the Electrostatic Screen Battery for Emissions Control (ESBEC). The device features high particle collection efficiency without adding to the exhaust backpressure and without the need for thermal regeneration of the collected particles. The ESBEC consists of a series of metal mesh screens coated with a superhydrophobic substance and an integrated carbon fiber ionizer to charge the incoming particles. Multiple pairs of screens (e.g., 5 pairs) are arranged in a battery, in which one screen of each pair is supplied with high voltage, and the other is grounded, producing electrostatic field produced across the screens. The application of a superhydrophobic coating onto the screens allows easy removal of the collected particles using liquid without the need for thermal regeneration. The current prototypes of the device were tested with fluorescent polystyrene latex (PSL) particles of 0.2 and 1.2 μm in size and at 25 and 105 L/min sampling flow rates. The average collection efficiency was ~87% for 0.2 μm and ~95% for 1.2 μm PSL particles. In addition, the ESBEC was tested with actual diesel exhaust particles; here its performance was verified by visually inspecting deposition of particles on an after-filter with the device ON and OFF. In the next stages of this work, the ESBEC will be challenged with diesel exhaust at different mass concentrations and for different collection time periods. PMID:28983124

  10. Design and Development of an Electrostatic Screen Battery for Emission Control (ESBEC).

    PubMed

    Han, Taewon; Mainelis, Gediminas

    2017-05-01

    Current diesel particulate filters (DPFs) can effectively capture the exhaust particles, but they add to engine backpressure and accumulate particles during their operation, which results in the need to regenerate the DPFs by burning off the collected particles periodically. This regeneration results in aerosol emissions, especially in the 10-30 nanometer size range and contributes to ultrafine particle pollution. In this research, we designed and developed a prototype of a novel diesel exhaust control device: the Electrostatic Screen Battery for Emissions Control (ESBEC). The device features high particle collection efficiency without adding to the exhaust backpressure and without the need for thermal regeneration of the collected particles. The ESBEC consists of a series of metal mesh screens coated with a superhydrophobic substance and an integrated carbon fiber ionizer to charge the incoming particles. Multiple pairs of screens (e.g., 5 pairs) are arranged in a battery, in which one screen of each pair is supplied with high voltage, and the other is grounded, producing electrostatic field produced across the screens. The application of a superhydrophobic coating onto the screens allows easy removal of the collected particles using liquid without the need for thermal regeneration. The current prototypes of the device were tested with fluorescent polystyrene latex (PSL) particles of 0.2 and 1.2 μm in size and at 25 and 105 L/min sampling flow rates. The average collection efficiency was ~87% for 0.2 μm and ~95% for 1.2 μm PSL particles. In addition, the ESBEC was tested with actual diesel exhaust particles; here its performance was verified by visually inspecting deposition of particles on an after-filter with the device ON and OFF. In the next stages of this work, the ESBEC will be challenged with diesel exhaust at different mass concentrations and for different collection time periods.

  11. New psychoactive substances in oral fluid of French and Belgian drivers in 2016.

    PubMed

    Richeval, Camille; Wille, Sarah Maria Richarda; Nachon-Phanithavong, Mélodie; Samyn, Nele; Allorge, Delphine; Gaulier, Jean-Michel

    2018-04-06

    Driving under the influence of drugs (DUID) is a worldwide problem with potentially major judiciary and life-threatening consequences. Up to now, only classical drugs of abuse (DOA) are tested for DUID detection. A challenging issue for drafting up-dated international drug policies is to take into account the recent and expanding new psychoactive substances (NPS) market. NPS consist in various narcotic or psychotropic drugs, most of them having a "legal" status, that replicate chemical structures and/or pharmacological effects of classical DOA. Although it is obvious that NPS can lead to impaired driving, the prevalence of NPS use in a DUID context is unknown since the applied roadside screening tests are not yet adapted for these compounds. Between January and December 2016, a total of 391 oral fluid specimens were obtained from used roadside immunochemical test devices for DOA (Drugwipe-5S ® device). These specimens were analyzed using liquid chromatography coupled with tandem mass spectrometry and high resolution mass spectrometry. NPS (mainly cathinone derivatives) were detected in 33 out of the 391 oral fluid samples. This NPS positivity rate of 8.4% in oral fluid of drivers who were submitted to a roadside drug testing in 2016 in France and in Belgium is comparable to the available blood data (NPS positivity rate of 7%) observed in 2015 in similar populations. Our results demonstrate the reality of driving after NPS use in French and Belgian drivers who were submitted to a roadside DOA test. As there is a lack of on-site detection methods to screen for NPS, the detection of NPS in a rapid and cost-effective DUID detection strategy is currently impossible. The expanding use of NPS, notably by drivers as reported here, and the inability of currently used drug detection tests, should be urgently addressed by road safety and law enforcement authorities. Copyright © 2018 Elsevier B.V. All rights reserved.

  12. How to report and interpret screening test properties: guidelines for driving researchers.

    PubMed

    Weaver, Bruce; Walter, Stephen D; Bédard, Michel

    2014-01-01

    One important goal of driving research is the development of a short but valid office-based screening test for fitness to drive of aging drivers. Several candidate tests have been proposed already, and no doubt others will be proposed in the future. It might seem obvious that authors advocating for the adoption of a particular screening test or procedure should report sensitivity, specificity, and other common screening test properties. Unfortunately, driving researchers have frequently failed to report any screening test properties. Others have reported screening test properties but have made basic mistakes such as calculating predictive values of positive and negative tests but reporting them incorrectly as sensitivity and specificity. These omissions and errors suggest that some driving researchers may be unaware of the importance of accurately reporting test properties when proposing a screening procedure and that others may need a refresher on how to calculate and interpret the most common screening test properties. Many good learning resources for screening and diagnostic tests are available, but most of them are intended for students and researchers in medicine, epidemiology, or public health. We hope that this tutorial in a prominent transportation journal will help lead to improved reporting and interpretation of screening test properties in articles that assess the usefulness of potential screening tools for fitness to drive.

  13. Factors associated with screening for glucose abnormalities after gestational diabetes mellitus: baseline cohort of the interventional IMPACT study.

    PubMed

    Bihan, H; Cosson, E; Khiter, C; Vittaz, L; Faghfouri, F; Leboeuf, D; Carbillon, L; Dauphin, H; Reach, G; Valensi, P

    2014-04-01

    Although it is important to screen women who have had gestational diabetes mellitus (GDM) for abnormal post-partum glucose levels, such testing is rarely performed. The aim of this study was to use data from the first observational phase of the IMPACT study to determine rates of screening within 6 months of delivery in a multiethnic cohort, focusing in particular on the effects of social deprivation and the risk of future diabetes. To investigate the frequency of post-partum screening, charts were analyzed, and all women attending four centres located in a deprived area who had had GDM between January 2009 and December 2010 were contacted by phone. The Evaluation of Precarity and Inequalities in Health Examination Centres (EPICES) deprivation index and Finnish Diabetes Risk Score (FINDRISK) questionnaire were also evaluated. Data were evaluable for 589 of the 719 women contacted (mean age: 33.4 ± 5.2 years; mean body mass index: 27.6 ± 5.4 kg/m(2)), and 196 (33.3%) reported having been screened. On multivariate analysis, factors associated with a lack of screening were smoking [odds ratio (OR): 0.42 (0.20-0.90), P<0.05], low consumption of fruit and vegetables [OR: 0.58 (0.39-0.82), P<0.01] and heavier offspring birth weight (P<0.05), although there were no differences in FINDRISK and EPICES scores between screened and unscreened women. One-third of women who had had GDM reported having been screened for dysglycaemia at 6 months post-partum. However, it is expected that the interventional phase of the IMPACT study will increase screening rates, especially in women with the risk factors associated with lower screening rates during this observational phase. Copyright © 2014 Elsevier Masson SAS. All rights reserved.

  14. Efficacy of screening for high blood pressure in dental health care

    PubMed Central

    2011-01-01

    Background There is consensus on the importance of early detection and treatment of high blood pressure. Dental care is one of few medical services to which a considerable proportion of the general population comes for regular check-ups. We tested the effects of blood pressure screening in dental care centres with subsequent work-up of subjects screening positive in primary health care (PHCC). Methods Altogether 1,149 subjects 40-65 years old or 20-39 years old with body mass index >25, and with no previously known hypertension, who came for a dental examination had their blood pressure measured with an Omron M4® automatic blood pressure reading device. Subjects with systolic blood pressure readings above 160 mmHg or diastolic above 90 mmHg were referred to their PHCC for a check up. Outcome data were obtained by scrutiny of PHCC and hospital patient records for hypertension diagnoses during the three years following screening. Results 237 (20.6%) subjects screened positive. Of these, 230 (97.1%) came to their PHCC within the 3-year follow-up period, as compared with 695 (76.2%) of those who screened negative (p < 0.0001). Of those who screened positive, 76 (32.1%) received a diagnosis of hypertension, as compared with 26 (2.9%) of those who screened negative. Sensitivity was 79.1%, specificity 84.8% and positive predictive value 30.1%. The number of subjects needed to screen to find one case of hypertension was 18. Conclusions Co-operation between dental and primary care for blood pressure screening and work-up appears to be an effective way of detecting previously unknown hypertension. PMID:21450067

  15. Bacillus subtilis as a bioindicator for estimating pentachlorophenol toxicity and concentration.

    PubMed

    Ayude, M A; Okada, E; González, J F; Haure, P M; Murialdo, S E

    2009-05-01

    Pentachlorophenol (PCP) and its sodium salt (Na-PCP) are extremely toxic chemicals responsible for important soil and groundwater pollution, mainly caused by wastes from wood-treatment plants, because chlorinated phenols are widely used as wood preservatives. The methods most commonly used for routine analysis of pesticides such as PCP and Na-PCP are high-performance liquid chromatography (HPLC) and gas chromatography-mass spectroscopy (GC-MS). A variety of rapid biological screening tests using marine organisms, bioluminescent bacteria, and enzymes have also been reported. In this study, rapid biological screening analysis using Bacillus subtilis was developed, to assess the biodegradation of PCP and its by-products in liquid samples. An empirical model is proposed for spectrophotometric analysis of Na-PCP concentration after growth of Bacillus subtilis.

  16. The role of physicians as medical review officers in workplace drug testing programs. In pursuit of the last nanogram.

    PubMed Central

    Clark, H W

    1990-01-01

    In discussing the role of physicians in workplace drug testing programs, I focus on the recent Department of Transportation regulations that require drug testing in such regulated industries as interstate trucking, air transportation, mass transit, and the railroads. These regulations require that applicable drug testing programs employ physicians as medical review officers to evaluate positive tests that have been screened and confirmed by different techniques to determine if there is a legal medical explanation for the result. The drug testing program tests for the presence of amphetamine, cocaine, tetrahydrocannabinol, opiates, and phencyclidine. If an employee testing positive has an acceptable medical explanation, the result is to be reported as negative. Little practical advice exists for medical review officers, and they must be aware of key elements of the regulations and potential trouble spots. PMID:2190419

  17. Breast cancer risk assessment and diagnosis model using fuzzy support vector machine based expert system

    NASA Astrophysics Data System (ADS)

    Dheeba, J.; Jaya, T.; Singh, N. Albert

    2017-09-01

    Classification of cancerous masses is a challenging task in many computerised detection systems. Cancerous masses are difficult to detect because these masses are obscured and subtle in mammograms. This paper investigates an intelligent classifier - fuzzy support vector machine (FSVM) applied to classify the tissues containing masses on mammograms for breast cancer diagnosis. The algorithm utilises texture features extracted using Laws texture energy measures and a FSVM to classify the suspicious masses. The new FSVM treats every feature as both normal and abnormal samples, but with different membership. By this way, the new FSVM have more generalisation ability to classify the masses in mammograms. The classifier analysed 219 clinical mammograms collected from breast cancer screening laboratory. The tests made on the real clinical mammograms shows that the proposed detection system has better discriminating power than the conventional support vector machine. With the best combination of FSVM and Laws texture features, the area under the Receiver operating characteristic curve reached .95, which corresponds to a sensitivity of 93.27% with a specificity of 87.17%. The results suggest that detecting masses using FSVM contribute to computer-aided detection of breast cancer and as a decision support system for radiologists.

  18. Comparison of clinical and survival characteristics between prostate cancer patients of PSA-based screening and clinical diagnosis in China.

    PubMed

    Xu, Libo; Wang, Jinguo; Guo, Baofeng; Zhang, Haixia; Wang, Kaichen; Wang, Ding; Dai, Chang; Zhang, Ling; Zhao, Xuejian

    2018-01-02

    Prostate-specific antigen (PSA)-based mass screening remains the most controversial topic in prostate cancer. PSA-based mass screening has not been widely used in China yet. The aim of our study was to evaluate the effect of the PSA-based screening in China. The cohort consisted of 1,012 prostate cancer patients. Data were retrospectively collected and clinical characteristics of the cohorts were investigated. Survival was analyzed for prostatic carcinoma of both PSA screened and clinically diagnosed patients according to clinical characteristics and the National Comprehensive Cancer Network (NCCN) risk classification. Cox Proportional Hazards Model analysis was done for risk predictor identification. The median age was 71 years old. Five-year overall and prostate-cancer-specific survival in prostatic adenocarcinoma patients were 77.52% and 79.65%; 10-year survivals were 62.57% and 68.60%, respectively. Survival was significantly poorer in patients with metastases and non-curative management. T staging and Gleason score by NCCN classification effectively stratified prostatic adenocarcinoma patients into different risk groups. T staging was a significant predictor of survival by COX Proportional Hazard Model. PSA screened patients had a significantly higher percentage diagnosed in early stage. PSA screened prostatic adenocarcinoma patients had a better prognosis in both overall and prostate cancer-specific survivals. This Chinese cohort had a lower overall and prostate cancer survival rate than it is reported in western countries. The incidence of early-stage prostate cancer found in PSA-based mass screening was high and there were significant differences in both overall and prostate cancer-specific survival between the PSA-screened and clinically diagnosed patients.

  19. Comparison of clinical and survival characteristics between prostate cancer patients of PSA-based screening and clinical diagnosis in China

    PubMed Central

    Xu, Libo; Wang, Jinguo; Guo, Baofeng; Zhang, Haixia; Wang, Kaichen; Wang, Ding; Dai, Chang; Zhang, Ling; Zhao, Xuejian

    2018-01-01

    Prostate-specific antigen (PSA)-based mass screening remains the most controversial topic in prostate cancer. PSA-based mass screening has not been widely used in China yet. The aim of our study was to evaluate the effect of the PSA-based screening in China. The cohort consisted of 1,012 prostate cancer patients. Data were retrospectively collected and clinical characteristics of the cohorts were investigated. Survival was analyzed for prostatic carcinoma of both PSA screened and clinically diagnosed patients according to clinical characteristics and the National Comprehensive Cancer Network (NCCN) risk classification. Cox Proportional Hazards Model analysis was done for risk predictor identification. The median age was 71 years old. Five-year overall and prostate-cancer-specific survival in prostatic adenocarcinoma patients were 77.52% and 79.65%; 10-year survivals were 62.57% and 68.60%, respectively. Survival was significantly poorer in patients with metastases and non-curative management. T staging and Gleason score by NCCN classification effectively stratified prostatic adenocarcinoma patients into different risk groups. T staging was a significant predictor of survival by COX Proportional Hazard Model. PSA screened patients had a significantly higher percentage diagnosed in early stage. PSA screened prostatic adenocarcinoma patients had a better prognosis in both overall and prostate cancer-specific survivals. This Chinese cohort had a lower overall and prostate cancer survival rate than it is reported in western countries. The incidence of early-stage prostate cancer found in PSA-based mass screening was high and there were significant differences in both overall and prostate cancer-specific survival between the PSA-screened and clinically diagnosed patients. PMID:29416625

  20. With the Advent of Tomosynthesis in the Workup of Mammographic Abnormality, is Spot Compression Mammography Now Obsolete? An Initial Clinical Experience.

    PubMed

    Ni Mhuircheartaigh, Neasa; Coffey, Louise; Fleming, Hannah; O' Doherty, Ann; McNally, Sorcha

    2017-09-01

    To determine if the routine use of spot compression mammography is now obsolete in the assessment of screen detected masses, asymmetries and architectural distortion since the availability of digital breast tomosynthesis. We introduced breast tomosynthesis in the workup of screen detected abnormalities in our screening center in January 2015. During an initial learning period with tomosynthesis standard spot compression views were also performed. Three consultant breast radiologists retrospectively reviewed all screening mammograms recalled for assessment over the first 6-month period. We assessed retrospectively whether there was any additional diagnostic information obtained from spot compression views not already apparent on tomography. All cases were also reviewed for any additional lesions detected by tomosynthesis, not detected on routine 2-view screening mammography. 548 women screened with standard 2-view digital screening mammography were recalled for assessment in the selected period and a total of 565 lesions were assessed. 341 lesions were assessed by both tomosynthesis and routine spot compression mammography. The spot compression view was considered more helpful than tomosynthesis in only one patient. This was because the breast was inadequately positioned for tomosynthesis and the area in question was not adequately imaged. Apart from this technical error there was no asymmetry, distortion or mass where spot compression provided more diagnostic information than tomosynthesis alone. We detected three additional cancers on tomosynthesis, not detected by routine screening mammography. From our initial experience with tomosynthesis we conclude that spot compression mammography is now obsolete in the assessment of screen detected masses, asymmetries and distortions where tomosynthesis is available. © 2017 Wiley Periodicals, Inc.

  1. Evaluation of microtiter-plate enzyme-linked immunosorbent assay for the analysis of triazine and chloroacetanilide herbicides in rainfall

    USGS Publications Warehouse

    Pomes, M.L.; Thurman, E.M.; Aga, D.S.; Goolsby, D.A.

    1998-01-01

    Triazine and chloroacetanilide concentrations in rainfall samples collected from a 23-state region of the United States were analyzed with microtiter-plate enzyme-linked immunosorbent assay (ELISA). Thirty-six percent of rainfall samples (2072 out of 5691) were confirmed using gas chromatography/mass spectrometry (GC/MS) to evaluate the operating performance of ELISA as a screening test. Comparison of ELISA to GC/MS results showed that the two ELISA methods accurately reported GC/MS results (m = 1), but with more variability evident with the triazine than with the chloroacetanilide ELISA. Bayes's rule, a standardized method to report the results of screening tests, indicated that the two ELISA methods yielded comparable predictive values (80%), but the triazine ELISA yielded a false- positive rate of 11.8% and the chloroacetanilide ELISA yielded a false- negative rate of 23.1%. The false-positive rate for the triazine ELISA may arise from cross reactivity with an unknown triazine or metabolite. The false-negative rate of the chloroacetanilide ELISA probably resulted from a combination of low sensitivity at the reporting limit of 0.15 ??g/L and a distribution characterized by 75% of the samples at or below the reporting limit of 0.15 ??g/L.Triazine and chloroacetanilide concentrations in rainfall samples collected from a 23-state region of the United States were analyzed with microtiter-plate enzyme-linked immunosorbent assay (ELISA). Thirty-six percent of rainfall samples (2072 out of 5691) were confirmed using gas chromatography/mass spectrometry (GC/MS) to evaluate the operating performance of ELISA as a screening test. Comparison of ELISA to GC/MS results showed that the two ELISA methods accurately reported GC/MS results (m = 1), but with more variability evident with the triazine than with the chloroacetanilide ELISA. Bayes's rule, a standardized method to report the results of screening tests, indicated that the two ELISA methods yielded comparable predictive values (80%), but the triazine ELISA yielded a false-positive rate of 11.8% and the chloroacetanilide ELISA yielded a false-negative rate of 23.1%. The false-positive rate for the triazine ELISA may arise from cross reactivity with an unknown triazine or metabolite. The false-negative rate of the chloroacetanilide ELISA probably resulted from a combination of low sensitivity at the reporting limit of 0.15 ??g/L and a distribution characterized by 75% of the samples at or below the reporting limit of 0.15 ??g/L.

  2. Multiplexed mass cytometry profiling of cellular states perturbed by small-molecule regulators

    PubMed Central

    Bodenmiller, Bernd; Zunder, Eli R.; Finck, Rachel; Chen, Tiffany J.; Savig, Erica S.; Bruggner, Robert V.; Simonds, Erin F.; Bendall, Sean C.; Sachs, Karen; Krutzik, Peter O.; Nolan, Garry P.

    2013-01-01

    The ability to comprehensively explore the impact of bio-active molecules on human samples at the single-cell level can provide great insight for biomedical research. Mass cytometry enables quantitative single-cell analysis with deep dimensionality, but currently lacks high-throughput capability. Here we report a method termed mass-tag cellular barcoding (MCB) that increases mass cytometry throughput by sample multiplexing. 96-well format MCB was used to characterize human peripheral blood mononuclear cell (PBMC) signaling dynamics, cell-to-cell communication, the signaling variability between 8 donors, and to define the impact of 27 inhibitors on this system. For each compound, 14 phosphorylation sites were measured in 14 PBMC types, resulting in 18,816 quantified phosphorylation levels from each multiplexed sample. This high-dimensional systems-level inquiry allowed analysis across cell-type and signaling space, reclassified inhibitors, and revealed off-target effects. MCB enables high-content, high-throughput screening, with potential applications for drug discovery, pre-clinical testing, and mechanistic investigation of human disease. PMID:22902532

  3. To Screen or Not to Screen? The Benefits and Harms of Screening Tests

    MedlinePlus

    ... issue To Screen or Not to Screen? The Benefits and Harms of Screening Tests En español Send ... test, talk with your doctor about the possible benefits and harms to help you decide what’s best ...

  4. A Comprehensive Review of School-Based Body Mass Index Screening Programs and Their Implications for School Health: Do the Controversies Accurately Reflect the Research?

    ERIC Educational Resources Information Center

    Ruggieri, Dominique G.; Bass, Sarah B.

    2015-01-01

    Background: Whereas legislation for body mass index (BMI) surveillance and screening programs has passed in 25 states, the programs are often subject to ethical debates about confidentiality and privacy, school-to-parent communication, and safety and self-esteem issues for students. Despite this debate, no comprehensive analysis has been completed…

  5. Computer-aided diagnosis workstation and network system for chest diagnosis based on multislice CT images

    NASA Astrophysics Data System (ADS)

    Satoh, Hitoshi; Niki, Noboru; Eguchi, Kenji; Moriyama, Noriyuki; Ohmatsu, Hironobu; Masuda, Hideo; Machida, Suguru

    2008-03-01

    Mass screening based on multi-helical CT images requires a considerable number of images to be read. It is this time-consuming step that makes the use of helical CT for mass screening impractical at present. To overcome this problem, we have provided diagnostic assistance methods to medical screening specialists by developing a lung cancer screening algorithm that automatically detects suspected lung cancers in helical CT images, a coronary artery calcification screening algorithm that automatically detects suspected coronary artery calcification and a vertebra body analysis algorithm for quantitative evaluation of osteoporosis likelihood by using helical CT scanner for the lung cancer mass screening. The function to observe suspicious shadow in detail are provided in computer-aided diagnosis workstation with these screening algorithms. We also have developed the telemedicine network by using Web medical image conference system with the security improvement of images transmission, Biometric fingerprint authentication system and Biometric face authentication system. Biometric face authentication used on site of telemedicine makes "Encryption of file" and Success in login" effective. As a result, patients' private information is protected. Based on these diagnostic assistance methods, we have developed a new computer-aided workstation and a new telemedicine network that can display suspected lesions three-dimensionally in a short time. The results of this study indicate that our radiological information system without film by using computer-aided diagnosis workstation and our telemedicine network system can increase diagnostic speed, diagnostic accuracy and security improvement of medical information.

  6. Testing modified gravity using a marked correlation function

    NASA Astrophysics Data System (ADS)

    Armijo, Joaquí n.; Cai, Yan-Chuan; Padilla, Nelson; Li, Baojiu; Peacock, John A.

    2018-05-01

    In theories of modified gravity with the chameleon screening mechanism, the strength of the fifth force depends on environment. This induces an environment dependence of structure formation, which differs from ΛCDM. We show that these differences can be captured by the marked correlation function. With the galaxy correlation functions and number densities calibrated to match between f(R) and ΛCDM models in simulations, we show that the marked correlation functions from using either the local galaxy number density or halo mass as the marks encode extra information, which can be used to test these theories. We discuss possible applications of these statistics in observations.

  7. Accurate mass screening and identification of emerging contaminants in environmental samples by liquid chromatography-hybrid linear ion trap Orbitrap mass spectrometry.

    PubMed

    Hogenboom, A C; van Leerdam, J A; de Voogt, P

    2009-01-16

    The European Reach legislation will possibly drive producers to develop newly designed chemicals that will be less persistent, bioaccumulative or toxic. If this innovation leads to an increased use of more hydrophilic chemicals it may result in higher mobilities of chemicals in the aqueous environment. As a result, the drinking water companies may face stronger demands on removal processes as the hydrophilic compounds inherently are more difficult to remove. Monitoring efforts will also experience a shift in focus to more water-soluble compounds. Screening source waters on the presence of (emerging) contaminants is an essential step in the control of the water cycle from source to tap water. In this article, some of our experiences are presented with the hybrid linear ion trap (LTQ) FT Orbitrap mass spectrometer, in the area of chemical water analysis. A two-pronged strategy in mass spectrometric research was employed: (i) exploring effluent, surface, ground- and drinking-water samples searching for accurate masses corresponding to target compounds (and their product ions) known from, e.g. priority lists or the scientific literature and (ii) full-scan screening of water samples in search of 'unknown' or unexpected masses, followed by MS(n) experiments to elucidate the structure of the unknowns. Applications of both approaches to emerging water contaminants are presented and discussed. Results are presented for target analysis search for pharmaceuticals, benzotriazoles, illicit drugs and for the identification of unknown compounds in a groundwater sample and in a polar extract of a landfill soil sample (a toxicity identification evaluation bioassay sample). The applications of accurate mass screening and identification described in this article demonstrate that the LC-LTQ FT Orbitrap MS is well equipped to meet the challenges posed by newly emerging polar contaminants.

  8. Screening of the binding of small molecules to proteins by desorption electrospray ionization mass spectrometry combined with protein microarray.

    PubMed

    Yao, Chenxi; Wang, Tao; Zhang, Buqing; He, Dacheng; Na, Na; Ouyang, Jin

    2015-11-01

    The interaction between bioactive small molecule ligands and proteins is one of the important research areas in proteomics. Herein, a simple and rapid method is established to screen small ligands that bind to proteins. We designed an agarose slide to immobilize different proteins. The protein microarrays were allowed to interact with different small ligands, and after washing, the microarrays were screened by desorption electrospray ionization mass spectrometry (DESI MS). This method can be applied to screen specific protein binding ligands and was shown for seven proteins and 34 known ligands for these proteins. In addition, a high-throughput screening was achieved, with the analysis requiring approximately 4 s for one sample spot. We then applied this method to determine the binding between the important protein matrix metalloproteinase-9 (MMP-9) and 88 small compounds. The molecular docking results confirmed the MS results, demonstrating that this method is suitable for the rapid and accurate screening of ligands binding to proteins. Graphical Abstract ᅟ.

  9. Collaborative Review: Risk-Based Prostate Cancer Screening

    PubMed Central

    Zhu, Xiaoye; Albertsen, Peter C.; Andriole, Gerald L.; Roobol, Monique J.; Schröder, Fritz H.; Vickers, Andrew J.

    2016-01-01

    Context Widespread mass screening of prostate cancer (PCa) is not recommended because the balance between benefits and harms is still not well established. The achieved mortality reduction comes with considerable harm such as unnecessary biopsies, overdiagnoses, and overtreatment. Therefore, patient stratification with regard to PCa risk and aggressiveness is necessary to identify those men who are at risk and may actually benefit from early detection. Objective This review critically examines the current evidence regarding risk-based PCa screening. Evidence acquisition A search of the literature was performed using the Medline database. Further studies were selected based on manual searches of reference lists and review articles. Evidence synthesis Prostate-specific antigen (PSA) has been shown to be the single most significant predictive factor for identifying men at increased risk of developing PCa. Especially in men with no additional risk factors, PSA alone provides an appropriate marker up to 30 yr into the future. After assessment of an early PSA test, the screening frequency may be determined based on individualized risk. A limited list of additional factors such as age, comorbidity, prostate volume, family history, ethnicity, and previous biopsy status have been identified to modify risk and are important for consideration in routine practice. In men with a known PSA, risk calculators may hold the promise of identifying those who are at increased risk of having PCa and are therefore candidates for biopsy. Conclusions PSA testing may serve as the foundation for a more risk-based assessment. However, the decision to undergo early PSA testing should be a shared one between the patient and his physician based on information balancing its advantages and disadvantages. PMID:22134009

  10. A Smartphone App to Screen for HIV-Related Neurocognitive Impairment

    PubMed Central

    Robbins, Reuben N.; Brown, Henry; Ehlers, Andries; Joska, John A.; Thomas, Kevin G.F.; Burgess, Rhonda; Byrd, Desiree; Morgello, Susan

    2014-01-01

    Background Neurocognitive Impairment (NCI) is one of the most common complications of HIV-infection, and has serious medical and functional consequences. However, screening for it is not routine and NCI often goes undiagnosed. Screening for NCI in HIV disease faces numerous challenges, such as limited screening tests, the need for specialized equipment and apparatuses, and highly trained personnel to administer, score and interpret screening tests. To address these challenges, we developed a novel smartphone-based screening tool, NeuroScreen, to detect HIV-related NCI that includes an easy-to-use graphical user interface with ten highly automated neuropsychological tests. Aims To examine NeuroScreen’s: 1) acceptability among patients and different potential users; 2) test construct and criterion validity; and 3) sensitivity and specificity to detect NCI. Methods Fifty HIV+ individuals were administered a gold-standard neuropsychological test battery, designed to detect HIV-related NCI, and NeuroScreen. HIV+ test participants and eight potential provider-users of NeuroScreen were asked about its acceptability. Results There was a high level of acceptability of NeuroScreen by patients and potential provider-users. Moderate to high correlations between individual NeuroScreen tests and paper-and-pencil tests assessing the same cognitive domains were observed. NeuroScreen also demonstrated high sensitivity to detect NCI. Conclusion NeuroScreen, a highly automated, easy-to-use smartphone-based screening test to detect NCI among HIV patients and usable by a range of healthcare personnel could help make routine screening for HIV-related NCI feasible. While NeuroScreen demonstrated robust psychometric properties and acceptability, further testing with larger and less neurocognitively impaired samples is warranted. PMID:24860624

  11. Motivators and barriers to mammography screening uptake by female health-care workers in primary health-care centres: a cross-sectional study.

    PubMed

    Nazzal, Zaher; Sholi, Hisham; Sholi, Suha B; Sholi, Mohammad B; Lahaseh, Rawya

    2018-02-21

    Mammography screening is an effective tool for early detection and management of breast cancer. Female health-care workers' awareness of breast cancer screening is important because their beliefs and behaviours could influence other women. The aim of this study was to assess mammography screening uptake by female health-care workers at primary health-care centres and to identify the primary motivators and barriers that affect uptake. This cross-sectional study included all governmental primary health-care centres in the West Bank. Governorates were grouped into three regions as follows: north West Bank (Nablus, Jenin, Tulkarm, Tubas, Qalqiliya, and Salfit), middle West Bank (Jerusalem, Jericho, and Ramallah), and south West Bank (Hebron, and Bethlehem). The study population included all female health-care workers older than 40 years. Those who performed mammography for a suspected mass or other breast abnormalities were excluded. A self-administered questionnaire was used to collect data on demographic characteristics, knowledge about mammography screening, the extent and regularity of mammography screening, and motivators and barriers influencing their mammography screening uptake. The rate of mammography screening uptake was calculated. χ 2 test and t tests were used to assess screening motivators and barriers. The study was approved by the Institutional Review Board of the An-Najah National University. Participation was voluntary, and written consent was obtained from each participant. 299 female health-care workers completed a self-administered questionnaire. The mean age of the participants was 46 years (SD 4·7). 284 (95%) women had adequate knowledge about breast cancer and mammography screening, and 149 (50%) women reported having had at least one mammogram. 62 (21%) women had had regular scheduled mammograms. The most frequent reported motivators were the perceived benefit that early detection of breast cancer is important for its management (269 [90%] women) and the belief that mammography can detect breast cancer before its symptoms appear (251 [84%] women). The most frequent barrier to mammography screening was being busy (140 [47%] women) and the lack of perceived susceptibility (125 [42%] women). Mammography screening was suboptimal in a population of female health-care workers. Educational interventions are needed to remove barriers that limit compliance to recommendations and to emphasise the importance of early detection in breast cancer management. Ensuring the availability and accessibility of screening services, particularly for health-care workers within their work settings, would improve the acceptance and compliance for mammography screening programmes. None. Copyright © 2018 Elsevier Ltd. All rights reserved.

  12. [Comparative study of protein markers in serum and bronchoalveolar lavage fluid from patients with lung cancer by surface-enhanced laser desorption ionization time of flight mass spectrometry].

    PubMed

    Zhou, Ji-hong; Liu, Guang-nan; Huang, Si-ming; Zhong, Xiao-ning; Su, Hong; Zhou, Yi

    2011-04-01

    To detect the protein markers in serum and bronchoalveolar lavage fluid (BALF) of the patients with lung cancer by surface-enhanced laser desorption ionization time of flight mass spectrometry (SELDI-TOF-MS) technology, and to explore if they can be used as markers for the diagnosis of lung cancer. SELDI-TOF-MS technology and protein chips weak cation exchange (WCX-2 chip) were used to detect the protein mass spectrum in serum and BALF of 35 patients with lung cancer and 18 cases of benign pulmonary diseases. The different protein markers were analyzed by Biomarker Pattern Software and the initial diagnosis models were set up. The diagnosis models were verified further by blind screen to confirm the efficacy of diagnosis. Five protein peaks in the sera of the patients with lung cancer were significantly higher (P < 0.05). The protein peak with a mass/charge ratio (M/Z) of 5639 was selected to establish the classification tree model. The sensitivity of diagnosis was 80% (28/35) and the specificity was 78% (14/18). The results verified by blind screen showed a sensitivity of 85% (17/20), a specificity of 90% (9/10), a crude accuracy (CA) of 87% (26/30) and Youden's index (γ) of 0.7. Eight protein peaks in the BALF of the patients with lung cancer were significantly higher (P < 0.05). The different protein peaks with M/Z of 7976 and 11 809 respectively were selected to establish the classification tree model. The sensitivity of diagnosis was 86% (30/35) and the specificity was 72% (13/18). The results verified by blind screen showed a sensitivity of 90% (18/20), a specificity of 90% (9/10), a CA of 90% (27/30) and γ of 0.8. There was a complementary role in combination of differential proteins in serum and BALF and the sensitivity, specificity and accuracy of diagnosis for lung cancer were 100% by parallel test. The SELDI-TOF-MS technology can screen out the differential protein markers in serum and BALF of the patients with lung cancer, which show high sensitivity and specificity as tumor markers. The differential proteins in the BALF may be more promising for clinical application.

  13. Confirmation of congenital adrenal hyperplasia by adrenal steroid profiling of filter paper dried blood samples using ultra-performance liquid chromatography-tandem mass spectrometry.

    PubMed

    Rossi, Claudia; Calton, Lisa; Brown, Heather A; Gillingwater, Scott; Wallace, A Michael; Petrucci, Francesca; Ciavardelli, Domenico; Urbani, Andrea; Sacchetta, Paolo; Morris, Michael

    2011-04-01

    The specificity of screening for congenital adrenal hyperplasia by direct measurement of 17-hydroxyprogesterone in filter paper dried blood spot samples by immunoassay is low and has a high false-positive rate. In order to reduce the false-positive rate of this test, we developed a rapid, robust, specific confirmatory procedure in which cortisol, 4-androstene-3,17-dione and 17-hydroxyprogesterone were measured simultaneously by ultra-performance liquid chromatography-tandem mass spectrometry. After extraction, samples were analysed by ultra-performance liquid chromatography-tandem mass spectrometry and 17-hydroxyprogesterone was quantified accurately. Other steroids were determined using stable deuterated internal standards. In total, 25 patient blood spot samples and 92 control samples were analysed. The assay was linear for 17-hydroxyprogesterone, with a coefficient of determination >0.997 and imprecision ≤ 6.5%. An upper limit of normal for 17-hydroxyprogester-one of 4.45 nmol/L was established by analysing a cohort of samples from unaffected newborns. In addition, a cut-off of 3.5 for the peak areas ratio (17-hydroxyprogesterone+4-androstene-3,17-dione)/cortisol, allows confirmation of the affected steroidogenic enzyme. A high throughput method for the detection of steroids related to congenital adrenal hyperplasia has been developed, allowing the false-positive rate associated with screening for 17-hydroxyprogesterone by immunoassay to be determined.

  14. Which screening tools can predict injury to the lower extremities in team sports?: a systematic review.

    PubMed

    Dallinga, Joan M; Benjaminse, Anne; Lemmink, Koen A P M

    2012-09-01

    Injuries to lower extremities are common in team sports such as soccer, basketball, volleyball, football and field hockey. Considering personal grief, disabling consequences and high costs caused by injuries to lower extremities, the importance for the prevention of these injuries is evident. From this point of view it is important to know which screening tools can identify athletes who are at risk of injury to their lower extremities. The aim of this article is to determine the predictive values of anthropometric and/or physical screening tests for injuries to the leg, anterior cruciate ligament (ACL), knee, hamstring, groin and ankle in team sports. A systematic review was conducted in MEDLINE (1966 to September 2011), EMBASE (1989 to September 2011) and CINAHL (1982 to September 2011). Based on inclusion criteria defined a priori, titles, abstracts and full texts were analysed to find relevant studies. The analysis showed that different screening tools can be predictive for injuries to the knee, ACL, hamstring, groin and ankle. For injuries in general there is some support in the literature to suggest that general joint laxity is a predictive measure for leg injuries. The anterior right/left reach distance >4 cm and the composite reach distance <4.0% of limb length in girls measured with the star excursion balance test (SEBT) may predict leg injuries. Furthermore, an increasing age, a lower hamstring/quadriceps (H : Q) ratio and a decreased range of motion (ROM) of hip abduction may predict the occurrence of leg injuries. Hyperextension of the knee, side-to-side differences in anterior-posterior knee laxity and differences in knee abduction moment between both legs are suggested to be predictive tests for sustaining an ACL injury and height was a predictive screening tool for knee ligament injuries. There is some evidence that when age increases, the probability of sustaining a hamstring injury increases. Debate exists in the analysed literature regarding measurement of the flexibility of the hamstring as a predictive screening tool, as well as using the H : Q ratio. Hip-adduction-to-abduction strength is a predictive test for hip adductor muscle strain. Studies do not agree on whether ROM of the hamstring is a predictive screening tool for groin injury. Body mass index and the age of an athlete could contribute to an ankle sprain. There is support in the literature to suggest that greater strength of the plantar flexors may be a predictive measure for sustaining an ankle injury. Furthermore, there is some agreement that the measurement of postural sway is a predictive test for an ankle injury. The screening tools mentioned above can be recommended to medical staff and coaches for screening their athletes. Future research should focus on prospective studies in larger groups and should follow athletes over several seasons.

  15. Combined radiogrammetry and texture analysis for early diagnosis of osteoporosis using Indian and Swiss data.

    PubMed

    Areeckal, Anu Shaju; Kamath, Jagannath; Zawadynski, Sophie; Kocher, Michel; S, Sumam David

    2018-05-26

    Osteoporosis is a bone disorder characterized by bone loss and decreased bone strength. The most widely used technique for detection of osteoporosis is the measurement of bone mineral density (BMD) using dual energy X-ray absorptiometry (DXA). But DXA scans are expensive and not widely available in low-income economies. In this paper, we propose a low cost pre-screening tool for the detection of low bone mass, using cortical radiogrammetry of third metacarpal bone and trabecular texture analysis of distal radius from hand and wrist radiographs. An automatic segmentation algorithm to automatically locate and segment the third metacarpal bone and distal radius region of interest (ROI) is proposed. Cortical measurements such as combined cortical thickness (CCT), cortical area (CA), percent cortical area (PCA) and Barnett Nordin index (BNI) were taken from the shaft of third metacarpal bone. Texture analysis of trabecular network at the distal radius was performed using features obtained from histogram, gray level Co-occurrence matrix (GLCM) and morphological gradient method (MGM). The significant cortical and texture features were selected using independent sample t-test and used to train classifiers to classify healthy subjects and people with low bone mass. The proposed pre-screening tool was validated on two ethnic groups, Indian sample population and Swiss sample population. Data of 134 subjects from Indian sample population and 65 subjects from Swiss sample population were analysed. The proposed automatic segmentation approach shows a detection accuracy of 86% in detecting the third metacarpal bone shaft and 90% in accurately locating the distal radius ROI. Comparison of the automatic radiogrammetry to the ground truth provided by experts show a mean absolute error of 0.04 mm for cortical width of healthy group, 0.12 mm for cortical width of low bone mass group, 0.22 mm for medullary width of healthy group, and 0.26 mm for medullary width of low bone mass group. Independent sample t-test was used to select the most discriminant features, to be used as input for training the classifiers. Pearson correlation analysis of the extracted features with DXA-BMD of lumbar spine (DXA-LS) shows significantly high correlation values. Classifiers were trained with the most significant features in the Indian and Swiss sample data. Weighted KNN classifier shows the best test accuracy of 78% for Indian sample data and 100% for Swiss sample data. Hence, combined automatic radiogrammetry and texture analysis is shown to be an effective low cost pre-screening tool for early diagnosis of osteoporosis. Copyright © 2018 Elsevier Ltd. All rights reserved.

  16. Advantages and Challenges of Dried Blood Spot Analysis by Mass Spectrometry Across the Total Testing Process.

    PubMed

    Zakaria, Rosita; Allen, Katrina J; Koplin, Jennifer J; Roche, Peter; Greaves, Ronda F

    2016-12-01

    Through the introduction of advanced analytical techniques and improved throughput, the scope of dried blood spot testing utilising mass spectrometric methods, has broadly expanded. Clinicians and researchers have become very enthusiastic about the potential applications of dried blood spot based mass spectrometric applications. Analysts on the other hand face challenges of sensitivity, reproducibility and overall accuracy of dried blood spot quantification. In this review, we aim to bring together these two facets to discuss the advantages and current challenges of non-newborn screening applications of dried blood spot quantification by mass spectrometry. To address these aims we performed a key word search of the PubMed and MEDLINE online databases in conjunction with individual manual searches to gather information. Keywords for the initial search included; "blood spot" and "mass spectrometry"; while excluding "newborn"; and "neonate". In addition, databases were restricted to English language and human specific. There was no time period limit applied. As a result of these selection criteria, 194 references were identified for review. For presentation, this information is divided into: 1) clinical applications; and 2) analytical considerations across the total testing process; being pre-analytical, analytical and post-analytical considerations. DBS analysis using MS applications is now broadly applied, with drug monitoring for both therapeutic and toxicological analysis being the most extensively reported. Several parameters can affect the accuracy of DBS measurement and further bridge experiments are required to develop adjustment rules for comparability between dried blood spot measures and the equivalent serum/plasma values. Likewise, the establishment of independent reference intervals for dried blood spot sample matrix is required.

  17. Doping control analysis of trimetazidine and characterization of major metabolites using mass spectrometric approaches.

    PubMed

    Sigmund, Gerd; Koch, Anja; Orlovius, Anne-Katrin; Guddat, Sven; Thomas, Andreas; Schänzer, Wilhelm; Thevis, Mario

    2014-01-01

    Since January 2014, the anti-anginal drug trimetazidine [1-(2,3,4-trimethoxybenzyl)-piperazine] has been classified as prohibited substance by the World Anti-Doping Agency (WADA), necessitating specific and robust detection methods in sports drug testing laboratories. In the present study, the implementation of the intact therapeutic agent into two different initial testing procedures based on gas chromatography-mass spectrometry (GC-MS) and liquid chromatography-tandem mass spectrometry (LC-MS/MS) is reported, along with the characterization of urinary metabolites by electrospray ionization-high resolution/high accuracy (tandem) mass spectrometry. For GC-MS analyses, urine samples were subjected to liquid-liquid extraction sample preparation, while LC-MS/MS analyses were conducted by established 'dilute-and-inject' approaches. Both screening methods were validated for trimetazidine concerning specificity, limits of detection (0.5-50 ng/mL), intra-day and inter-day imprecision (<20%), and recovery (41%) in case of the GC-MS-based method. In addition, major metabolites such as the desmethylated trimetazidine and the corresponding sulfoconjugate, oxo-trimetazidine, and trimetazidine-N-oxide as identified in doping control samples were used to complement the LC-MS/MS-based assay, although intact trimetazidine was found at highest abundance of the relevant trimetazidine-related analytes in all tested sports drug testing samples. Retrospective data mining regarding doping control analyses conducted between 1999 and 2013 at the Cologne Doping Control Laboratory concerning trimetazidine revealed a considerable prevalence of the drug particularly in endurance and strength sports accounting for up to 39 findings per year. Copyright © 2014 John Wiley & Sons, Ltd.

  18. Prostate Cancer Screening

    MedlinePlus

    ... decrease the risk of dying from cancer. Scientists study screening tests to find those with the fewest risks and ... or routine screening test for prostate cancer. Screening tests for prostate cancer are under study, and there are screening clinical trials taking place ...

  19. The utility of childhood and adolescent obesity assessment in relation to adult health.

    PubMed

    Goldhaber-Fiebert, Jeremy D; Rubinfeld, Rachel E; Bhattacharya, Jay; Robinson, Thomas N; Wise, Paul H

    2013-02-01

    High childhood obesity prevalence has raised concerns about future adult health, generating calls for obesity screening of young children. To estimate how well childhood obesity predicts adult obesity and to forecast obesity-related health of future US adults. Longitudinal statistical analyses; microsimulations combining multiple data sets. National Longitudinal Survey of Youth, Population Study of Income Dynamics, and National Health and Nutrition Evaluation Surveys. The authors estimated test characteristics and predictive values of childhood body mass index to identify 2-, 5-, 10-, and 15 year-olds who will become obese adults. The authors constructed models relating childhood body mass index to obesity-related diseases through middle age stratified by sex and race. Twelve percent of 18-year-olds were obese. While screening at age 5 would miss 50% of those who become obese adults, screening at age 15 would miss 9%. The predictive value of obesity screening below age 10 was low even when maternal obesity was included as a predictor. Obesity at age 5 was a substantially worse predictor of health in middle age than was obesity at age 15. For example, the relative risk of developing diabetes as adults for obese white male 15-year-olds was 4.5 versus otherwise similar nonobese 15-year-olds. For obese 5-year-olds, the relative risk was 1.6. Main results do not include Hispanics due to sample size. Past relationships between childhood and adult obesity and health may change in the future. Early childhood obesity assessment adds limited information to later childhood assessment. Targeted later childhood approaches or universal strategies to prevent unhealthy weight gain should be considered.

  20. Rapid analysis of aminoglycoside antibiotics in bovine tissues using disposable pipette extraction and ultrahigh performance liquid chromatography-tandem mass spectrometry.

    PubMed

    Lehotay, Steven J; Mastovska, Katerina; Lightfield, Alan R; Nuñez, Alberto; Dutko, Terry; Ng, Chilton; Bluhm, Louis

    2013-10-25

    A high-throughput qualitative screening and identification method for 9 aminoglycosides of regulatory interest has been developed, validated, and implemented for bovine kidney, liver, and muscle tissues. The method involves extraction at previously validated conditions, cleanup using disposable pipette extraction, and analysis by a 3 min ultrahigh-performance liquid chromatography-tandem mass spectrometry (UHPLC-MS/MS) method. The drug analytes include neomycin, streptomycin, dihydrosptreptomycin, and spectinomycin, which have residue tolerances in bovine in the US, and kanamicin, gentamicin, apramycin, amikacin, and hygromycin, which do not have US tolerances established in bovine tissues. Tobramycin was used as an internal standard. An additional drug, paromomycin also was validated in the method, but it was dropped during implementation due to conversion of neomycin into paromomycin. Proposed fragmentation patterns for the monitored ions of each analyte were elucidated with the aid of high resolution MS using a quadrupole-time-of-flight instrument. Recoveries from spiking experiments at regulatory levels of concern showed that all analytes averaged 70-120% recoveries in all tissues, except hygromycin averaged 61% recovery. Lowest calibrated levels were as low as 0.005 μg/g in matrix extracts, which approximately corresponded to the limit of detection for screening purposes. Drug identifications at levels <0.05 μg/g were made in spiked and/or real samples for all analytes and tissues tested. Analyses of 60 samples from 20 slaughtered cattle previously screened positive for aminoglycosides showed that this method worked well in practice. The UHPLC-MS/MS method has several advantages compared to the previous microbial inhibition screening assay, especially for distinguishing individual drugs from a mixture and improving identification of gentamicin in tissue samples. Published by Elsevier B.V.

  1. A High Resolution/Accurate Mass (HRAM) Data-Dependent MS3 Neutral Loss Screening, Classification, and Relative Quantitation Methodology for Carbonyl Compounds in Saliva

    NASA Astrophysics Data System (ADS)

    Dator, Romel; Carrà, Andrea; Maertens, Laura; Guidolin, Valeria; Villalta, Peter W.; Balbo, Silvia

    2017-04-01

    Reactive carbonyl compounds (RCCs) are ubiquitous in the environment and are generated endogenously as a result of various physiological and pathological processes. These compounds can react with biological molecules inducing deleterious processes believed to be at the basis of their toxic effects. Several of these compounds are implicated in neurotoxic processes, aging disorders, and cancer. Therefore, a method characterizing exposures to these chemicals will provide insights into how they may influence overall health and contribute to disease pathogenesis. Here, we have developed a high resolution accurate mass (HRAM) screening strategy allowing simultaneous identification and relative quantitation of DNPH-derivatized carbonyls in human biological fluids. The screening strategy involves the diagnostic neutral loss of hydroxyl radical triggering MS3 fragmentation, which is only observed in positive ionization mode of DNPH-derivatized carbonyls. Unique fragmentation pathways were used to develop a classification scheme for characterizing known and unanticipated/unknown carbonyl compounds present in saliva. Furthermore, a relative quantitation strategy was implemented to assess variations in the levels of carbonyl compounds before and after exposure using deuterated d 3 -DNPH. This relative quantitation method was tested on human samples before and after exposure to specific amounts of alcohol. The nano-electrospray ionization (nano-ESI) in positive mode afforded excellent sensitivity with detection limits on-column in the high-attomole levels. To the best of our knowledge, this is the first report of a method using HRAM neutral loss screening of carbonyl compounds. In addition, the method allows simultaneous characterization and relative quantitation of DNPH-derivatized compounds using nano-ESI in positive mode.

  2. Comprehensive screening and quantification of veterinary drugs in milk using UPLC–ToF-MS

    PubMed Central

    Rutgers, P.; Oosterink, E.; Lasaroms, J. J. P.; Peters, R. J. B.; van Rhijn, J. A.; Nielen, M. W. F.

    2008-01-01

    Ultra-performance liquid chromatography combined with time-of-flight mass spectrometry (UPLC–ToF-MS) has been used for screening and quantification of more than 100 veterinary drugs in milk. The veterinary drugs represent different classes including benzimidazoles, macrolides, penicillins, quinolones, sulphonamides, pyrimidines, tetracylines, nitroimidazoles, tranquillizers, ionophores, amphenicols and non-steroidal anti-inflammatory agents (NSAIDs). After protein precipitation, centrifugation and solid-phase extraction (SPE), the extracts were analysed by UPLC–ToF-MS. From the acquired full scan data the drug-specific ions were extracted for construction of the chromatograms and evaluation of the results. The analytical method was validated according to the EU guidelines (2002/657/EC) for a quantitative screening method. At the concentration level of interest (MRL level) the results for repeatability (%RSD < 20% for 86% of the compounds), reproducibility (%RSD < 40% for 96% of the compounds) and the accuracy (80–120% for 88% of the compounds) were satisfactory. Evaluation of the CCβ values and the linearity results demonstrates that the developed method shows adequate sensitivity and linearity to provide quantitative results. Furthermore, the method is accurate enough to differentiate between suspected and negative samples or drug concentrations below or above the MRL. A set of 100 samples of raw milk were screened for residues. No suspected (positive) results were obtained except for the included blind reference sample containing sulphamethazine (88 μg/l) that tested positive for this compound. UPLC–ToF-MS combines high resolution for both LC and MS with high mass accuracy which is very powerful for the multi-compound analysis of veterinary drugs. The technique seems to be powerful enough for the analysis of not only veterinary drugs but also organic contaminants like pesticides, mycotoxins and plant toxins in one single method. PMID:18491081

  3. The effects of gray scale image processing on digital mammography interpretation performance.

    PubMed

    Cole, Elodia B; Pisano, Etta D; Zeng, Donglin; Muller, Keith; Aylward, Stephen R; Park, Sungwook; Kuzmiak, Cherie; Koomen, Marcia; Pavic, Dag; Walsh, Ruth; Baker, Jay; Gimenez, Edgardo I; Freimanis, Rita

    2005-05-01

    To determine the effects of three image-processing algorithms on diagnostic accuracy of digital mammography in comparison with conventional screen-film mammography. A total of 201 cases consisting of nonprocessed soft copy versions of the digital mammograms acquired from GE, Fischer, and Trex digital mammography systems (1997-1999) and conventional screen-film mammograms of the same patients were interpreted by nine radiologists. The raw digital data were processed with each of three different image-processing algorithms creating three presentations-manufacturer's default (applied and laser printed to film by each of the manufacturers), MUSICA, and PLAHE-were presented in soft copy display. There were three radiologists per presentation. Area under the receiver operating characteristic curve for GE digital mass cases was worse than screen-film for all digital presentations. The area under the receiver operating characteristic for Trex digital mass cases was better, but only with images processed with the manufacturer's default algorithm. Sensitivity for GE digital mass cases was worse than screen film for all digital presentations. Specificity for Fischer digital calcifications cases was worse than screen film for images processed in default and PLAHE algorithms. Specificity for Trex digital calcifications cases was worse than screen film for images processed with MUSICA. Specific image-processing algorithms may be necessary for optimal presentation for interpretation based on machine and lesion type.

  4. Overnight dexamethasone suppression test: a reliable screen for Cushing's syndrome in the obese.

    PubMed

    Ness-Abramof, Rosane; Nabriski, Dan; Apovian, Caroline M; Niven, Mark; Weiss, Eliahu; Shapiro, Menachem S; Shenkman, Louis

    2002-12-01

    Reevaluation of the validity of the 1-mg overnight dexamethasone suppression test (ODST) as a screening test for Cushing's syndrome in obese patients. Eighty-six obese patients (body mass index, 30 to 53 kg/m(2)) that were referred to a general endocrine outpatient clinic for evaluation of simple obesity, diabetes mellitus, hypertension, polycystic ovary disease, or pituitary tumor. One milligram dexamethasone was administered orally at 11:00 PM, and serum cortisol levels were measured the following morning between 8:00 AM and 9:00 AM. Suppression of serum cortisol to <80 nM (3 micro g/dL) was chosen as the cut-off point for normal suppression. Patients with serum cortisol levels > or =80 nM were evaluated for Cushing's syndrome. Suppression of morning cortisol levels to <80 nM occurred in 79 of the 86 obese patients. Seven patients had serum cortisol levels higher than 80 nM; five were eventually diagnosed with Cushing's syndrome and two were considered false positive results in view of normal 24-hour free urinary cortisol and normal suppression on a low dose dexamethasone suppression test (0.5 mg of dexamethasone every 6 hours for 2 days). We found a false positive rate of 2.3% for the ODST using a cut-off serum cortisol of 80 nM. The ODST is a valid screening test for Cushing's syndrome in the obese population. The false positive rate was 2.3%, even when using a strict cut-off serum cortisol of 80 nM. Abnormal cortisol suppression in obese patients should be investigated and not be considered false positive results.

  5. Staged decrease of physical ability on the locomotive syndrome risk test is related to neuropathic pain, nociceptive pain, shoulder complaints, and quality of life in middle-aged and elderly people - The utility of the locomotive syndrome risk test.

    PubMed

    Imagama, Shiro; Hasegawa, Yukiharu; Ando, Kei; Kobayashi, Kazuyoshi; Hida, Tetsuro; Ito, Kenyu; Tsushima, Mikito; Nishida, Yoshihiro; Ishiguro, Naoki

    2017-11-01

    A locomotive syndrome (LS) risk test for evaluation of physical ability is recently proposed. The objective of this study is to evaluate the utility of this test by examining physical ability, neuropathic pain, nociceptive pain, shoulder complaints, and quality of life (QOL). A prospective cohort study was conducted in 523 subjects (240 males, 283 females; mean age: 63.3 years) at a health checkup. Data collected using visual analog scales (VAS) for shoulder pain, low back pain, sciatica, and knee pain, neuropathic pain, shoulder complaint, body mass index (BMI), osteoporosis, and SF-36 were compared among three LS risk stages. Subjects in LS risk stage 1 (24%) had significantly more osteoporosis, slower gait speed, weaker muscle strength and higher VAS, with no difference in age and BMI compared to those with no LS risk (50%). Subjects in stage 2 (26%) had significantly poorer results for all items. Shoulder complaint, neuropathic pain and QOL differed significantly among all three groups and worsened with decline in mobility on the LS risk test. LS risk test is easy and useful screening tool for evaluation of mobility and for screening for pain and complaint associated with activity of daily living and QOL.

  6. Evaluation of a Rapid Diagnostic Test for Yaws Infection in a Community Surveillance Setting

    PubMed Central

    Marks, Michael; Goncalves, Adriana; Vahi, Ventis; Sokana, Oliver; Puiahi, Elliot; Zhang, Zaixing; Dalipanda, Tenneth; Bottomley, Christian; Mabey, David; Solomon, Anthony W.

    2014-01-01

    Yaws is a non-venereal treponemal infection caused by Treponema pallidum ssp. pertenue. The WHO has launched a worldwide control programme, which aims to eradicate yaws by 2020. The development of a rapid diagnostic test (RDT) for serological diagnosis in the isolated communities affected by yaws is a key requirement for the successful implementation of the WHO strategy. We conducted a study to evaluate the utility of the DPP test in screening for yaws, utilizing samples collected as part of a community prevalence survey conducted in the Solomon Islands. 415 serum samples were tested using both traditional syphilis serology (TPPA and quantitative RPR) and the Chembio DPP Syphilis Screen and Confirm RDT. We calculated the sensitivity and specificity of the RDT as compared to gold standard serology. The sensitivity of the RDT against TPPA was 58.5% and the specificity was 97.6%. The sensitivity of the RDT against RPR was 41.7% and the specificity was 95.2%. The sensitivity of the DPP was strongly related to the RPR titre with a sensitivity of 92.0% for an RPR titre of >1/16. Wider access to DPP testing would improve our understanding of worldwide yaws case reporting and the test may play a key role in assessing patients presenting with yaws like lesions in a post-mass drug administration (MDA) setting. PMID:25211018

  7. Evaluation of a rapid diagnostic test for yaws infection in a community surveillance setting.

    PubMed

    Marks, Michael; Goncalves, Adriana; Vahi, Ventis; Sokana, Oliver; Puiahi, Elliot; Zhang, Zaixing; Dalipanda, Tenneth; Bottomley, Christian; Mabey, David; Solomon, Anthony W

    2014-09-01

    Yaws is a non-venereal treponemal infection caused by Treponema pallidum ssp. pertenue. The WHO has launched a worldwide control programme, which aims to eradicate yaws by 2020. The development of a rapid diagnostic test (RDT) for serological diagnosis in the isolated communities affected by yaws is a key requirement for the successful implementation of the WHO strategy. We conducted a study to evaluate the utility of the DPP test in screening for yaws, utilizing samples collected as part of a community prevalence survey conducted in the Solomon Islands. 415 serum samples were tested using both traditional syphilis serology (TPPA and quantitative RPR) and the Chembio DPP Syphilis Screen and Confirm RDT. We calculated the sensitivity and specificity of the RDT as compared to gold standard serology. The sensitivity of the RDT against TPPA was 58.5% and the specificity was 97.6%. The sensitivity of the RDT against RPR was 41.7% and the specificity was 95.2%. The sensitivity of the DPP was strongly related to the RPR titre with a sensitivity of 92.0% for an RPR titre of >1/16. Wider access to DPP testing would improve our understanding of worldwide yaws case reporting and the test may play a key role in assessing patients presenting with yaws like lesions in a post-mass drug administration (MDA) setting.

  8. A Comparison of Parallel and Integrated Models for Implementation of Routine HIV Screening in a Large, Urban Emergency Department.

    PubMed

    Hankin, Abigail; Freiman, Heather; Copeland, Brittney; Travis, Natasha; Shah, Bijal

    2016-01-01

    This study compared two approaches for implementation of non-targeted HIV screening in the emergency department (ED): (1) designated HIV counselors screening in parallel with ED care and (2) nurse-based screening integrated into patient triage. A retrospective analysis was performed to compare parallel and integrated screening models using data from the first 12 months of each program. Data for the parallel screening model were extracted from information collected by HIV test counselors and the electronic medical record (EMR). Integrated screening model data were extracted from the EMR and supplemented by data collected by HIV social workers during patient interaction. For both programs, data included demographics, HIV test offer, test acceptance or declination, and test result. A Z-test between two proportions was performed to compare screening frequencies and results. During the first 12 months of parallel screening, approximately 120,000 visits were made to the ED, with 3,816 (3%) HIV tests administered and 65 (2%) new diagnoses of HIV infection. During the first 12 months of integrated screening, 111,738 patients were triaged in the ED, with 16,329 (15%) patients tested and 190 (1%) new diagnoses. Integrated screening resulted in an increased frequency of HIV screening compared with parallel screening (0.15 tests per ED patient visit vs. 0.03 tests per ED patient visit, p<0.001) and an increase in the absolute number of new diagnoses (190 vs. 65), representing a slight decrease in the proportion of new diagnoses (1% vs. 2%, p=0.007). Non-targeted, integrated HIV screening, with test offer and order by ED nurses during patient triage, is feasible and resulted in an increased frequency of HIV screening and a threefold increase in the absolute number of newly identified HIV-positive patients.

  9. Incidental findings of elevated random plasma glucose in the ED as a prompt for outpatient diabetes screening: a retrospective study

    PubMed Central

    Friedman, Steven Marc; Vallipuram, Janaki; Baswick, Brenda

    2013-01-01

    Objective To determine whether random plasma glucose (RPG) collected from patients without known impaired glucose metabolism (IGM) in the emergency department (ED) is a useful screen for diabetes or prediabetes. Design Retrospective cohort study. Setting ED of a Canadian teaching hospital over 1 month. Participants Adult patients in ED with RPG over 7 mmol/L were recruited for participation. Exclusion criteria included known diabetes, hospital admission and inability to consent. Participants were contacted by mail, encouraged to follow-up with their family physician (FP) for further testing and subsequently interviewed. Outcome measures The primary outcome measure was the proportion of patients in the ED with RPG over 7 mmol/L and no previous diagnosis of IGM who were diagnosed with diabetes or prediabetes after secondary testing by FP with oral glucose tolerance test or fasting plasma glucose (FPG). Secondary outcomes included patient characteristics (age, gender, body mass index and language) and (2) compliance with advice to seek an appropriate follow-up care. Results RPG was drawn on approximately one-third (33%, n=1149) of the 3470 patients in the ED in March 2010. RPG over 7 mmol/L was detected in 24% (n=278) of patients, and after first telephone follow-up, 32% (n=88/278) met the inclusion criteria and were advised to seek confirmatory testing. 41% (n=114/278) of patients were excluded for known diabetes. 73% of patients contacted (n=64/88) followed up with their FP. 12.5% (n=11/88) of patients had abnormal FPG, and of these 11% (n=10/88) were encouraged to initiate lifestyle modifications and 1% (n=1/88) was started on an oral hypoglycaemic agent. For 7% (n=6/88) of patients, FP's declined to do follow-up fasting blood work. Conclusions Elevated RPG in the ED is useful for identification of patients at risk for IGM and in need of further diabetic screening. Emergency physicians should advise patients with elevated RPG to consider screening for diabetes. For ED screening to be successful, patient education and collaboration with FPs are essential. PMID:24353254

  10. Incidental findings of elevated random plasma glucose in the ED as a prompt for outpatient diabetes screening: a retrospective study.

    PubMed

    Friedman, Steven Marc; Vallipuram, Janaki; Baswick, Brenda

    2013-12-18

    To determine whether random plasma glucose (RPG) collected from patients without known impaired glucose metabolism (IGM) in the emergency department (ED) is a useful screen for diabetes or prediabetes. Retrospective cohort study. ED of a Canadian teaching hospital over 1 month. Adult patients in ED with RPG over 7 mmol/L were recruited for participation. Exclusion criteria included known diabetes, hospital admission and inability to consent. Participants were contacted by mail, encouraged to follow-up with their family physician (FP) for further testing and subsequently interviewed. The primary outcome measure was the proportion of patients in the ED with RPG over 7 mmol/L and no previous diagnosis of IGM who were diagnosed with diabetes or prediabetes after secondary testing by FP with oral glucose tolerance test or fasting plasma glucose (FPG). Secondary outcomes included patient characteristics (age, gender, body mass index and language) and (2) compliance with advice to seek an appropriate follow-up care. RPG was drawn on approximately one-third (33%, n=1149) of the 3470 patients in the ED in March 2010. RPG over 7 mmol/L was detected in 24% (n=278) of patients, and after first telephone follow-up, 32% (n=88/278) met the inclusion criteria and were advised to seek confirmatory testing. 41% (n=114/278) of patients were excluded for known diabetes. 73% of patients contacted (n=64/88) followed up with their FP. 12.5% (n=11/88) of patients had abnormal FPG, and of these 11% (n=10/88) were encouraged to initiate lifestyle modifications and 1% (n=1/88) was started on an oral hypoglycaemic agent. For 7% (n=6/88) of patients, FP's declined to do follow-up fasting blood work. Elevated RPG in the ED is useful for identification of patients at risk for IGM and in need of further diabetic screening. Emergency physicians should advise patients with elevated RPG to consider screening for diabetes. For ED screening to be successful, patient education and collaboration with FPs are essential.

  11. Risks of Prostate Cancer Screening

    MedlinePlus

    ... decrease the risk of dying from cancer. Scientists study screening tests to find those with the fewest risks and ... or routine screening test for prostate cancer. Screening tests for prostate cancer are under study, and there are screening clinical trials taking place ...

  12. Novel strategy for the determination of illegal adulterants in health foods and herbal medicines using high-performance liquid chromatography with high-resolution mass spectrometry.

    PubMed

    Wang, Zhe; Wu, Caisheng; Wang, Gangli; Zhang, Qingsheng; Zhang, Jinlan

    2015-03-01

    The detection, confirmation, and quantification of multiple illegal adulterants in health foods and herbal medicines by using a single analytical method are a challenge. This paper reports on a new strategy to meet this challenge by employing high-performance liquid chromatography coupled with high-resolution mass spectrometry and a mass spectral tree similarity filter technique. This analytical method can rapidly collect high-resolution, high-accuracy, optionally multistage mass data for compounds in samples. After a preliminary screening by retention time and high-resolution mass spectral data, known illegal adulterants can be detected. The mass spectral tree similarity filter technique has been applied to rapidly confirm these adulterants and simultaneously discover unknown ones. By using full-scan mass spectra as stem and data-dependent subsequent stage mass spectra to form branches, mass spectrometry data from detected compounds are converted into mass spectral trees. The known or unknown illegal adulterants in the samples are confirmed or discovered based on the similarity between their mass spectral trees and those of the references in a library, and they are finally quantified against standard curves. This new strategy has been tested by using 50 samples, and the illegal adulterants were rapidly and effectively detected, confirmed and quantified. © 2015 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  13. High-throughput tandem mass spectrometry multiplex analysis for newborn urinary screening of creatine synthesis and transport disorders, Triple H syndrome and OTC deficiency.

    PubMed

    Auray-Blais, Christiane; Maranda, Bruno; Lavoie, Pamela

    2014-09-25

    Creatine synthesis and transport disorders, Triple H syndrome and ornithine transcarbamylase deficiency are treatable inborn errors of metabolism. Early screening of patients was found to be beneficial. Mass spectrometry analysis of specific urinary biomarkers might lead to early detection and treatment in the neonatal period. We developed a high-throughput mass spectrometry methodology applicable to newborn screening using dried urine on filter paper for these aforementioned diseases. A high-throughput methodology was devised for the simultaneous analysis of creatine, guanidineacetic acid, orotic acid, uracil, creatinine and respective internal standards, using both positive and negative electrospray ionization modes, depending on the compound. The precision and accuracy varied by <15%. Stability during storage at different temperatures was confirmed for three weeks. The limits of detection and quantification for each biomarker varied from 0.3 to 6.3 μmol/l and from 1.0 to 20.9 μmol/l, respectively. Analyses of urine specimens from affected patients revealed abnormal results. Targeted biomarkers in urine were detected in the first weeks of life. This rapid, simple and robust liquid chromatography/tandem mass spectrometry methodology is an efficient tool applicable to urine screening for inherited disorders by biochemical laboratories. Copyright © 2014 Elsevier B.V. All rights reserved.

  14. Nontargeted Screening Method for Illegal Additives Based on Ultrahigh-Performance Liquid Chromatography-High-Resolution Mass Spectrometry.

    PubMed

    Fu, Yanqing; Zhou, Zhihui; Kong, Hongwei; Lu, Xin; Zhao, Xinjie; Chen, Yihui; Chen, Jia; Wu, Zeming; Xu, Zhiliang; Zhao, Chunxia; Xu, Guowang

    2016-09-06

    Identification of illegal additives in complex matrixes is important in the food safety field. In this study a nontargeted screening strategy was developed to find illegal additives based on ultrahigh-performance liquid chromatography-high-resolution mass spectrometry (UHPLC-HRMS). First, an analytical method for possible illegal additives in complex matrixes was established including fast sample pretreatment, accurate UHPLC separation, and HRMS detection. Second, efficient data processing and differential analysis workflow were suggested and applied to find potential risk compounds. Third, structure elucidation of risk compounds was performed by (1) searching online databases [Metlin and the Human Metabolome Database (HMDB)] and an in-house database which was established at the above-defined conditions of UHPLC-HRMS analysis and contains information on retention time, mass spectra (MS), and tandem mass spectra (MS/MS) of 475 illegal additives, (2) analyzing fragment ions, and (3) referring to fragmentation rules. Fish was taken as an example to show the usefulness of the nontargeted screening strategy, and six additives were found in suspected fish samples. Quantitative analysis was further carried out to determine the contents of these compounds. The satisfactory application of this strategy in fish samples means that it can also be used in the screening of illegal additives in other kinds of food samples.

  15. Characteristics of invasive breast cancer and overall survival of patients eligible for mass breast cancer screening in Guadeloupe compared to those of the preceding age group.

    PubMed

    Kadhel, Philippe; Borja De Mozota, Daphné; Gaumond, Stéphanie; Deloumeaux, Jacqueline

    2017-10-01

    Mass breast cancer screening is offered to French women between the ages of 50 and 74. In the French overseas department of Guadeloupe, where the population is of mostly African ancestry, a low age at diagnosis of breast cancer has been reported, as for African-Americans. This raises the question of whether breast cancer is more aggressive in the age group preceding that eligible for mass screening (40-49) in Guadeloupe. We compared the tumor-related prognostic factors, first line therapy and overall survival rates of breast cancer cases diagnosed between the 40-49 and 50-74 age groups, based on reports of the cancer registry of Guadeloupe for the period 2008-2013. The characteristics studied, risk of death after breast cancer (HR 0.84 [95% CI: 0.58-1.22] and overall survival, did not differ significantly between the two groups, except for higher tumor size (28.8 vs 24.0; p=0.004) in the younger group. These results do not show a pattern of more aggressive breast cancer in the age group preceding that eligible for mass screening in Guadeloupe. Copyright © 2017 Elsevier Ltd. All rights reserved.

  16. [Maternal and neonatal vitamin B12 deficiency detected by expanded newborn screening].

    PubMed

    Papp, Ferenc; Rácz, Gábor; Lénárt, István; Kóbor, Jenő; Bereczki, Csaba; Karg, Eszter; Baráth, Ákos

    2017-12-01

    Infant vitamin B 12 deficiency can manifest as a severe neurodegenerative disorder and is usually caused by maternal deficiency due to vegetarian diet or pernicious anaemia. Its early recognition and treatment can prevent potentially serious and irreversible neurologic damage. Biochemically, vitamin B 12 deficiency leads to an accumulation of methylmalonic acid, homocysteine, and propionylcarnitine. Expanded newborn screening using tandem mass spectrometry may identify neonatal and maternal vitamin B 12 deficiency by measurement of propionylcarnitine and other metabolites in the dried blood spot sample of newborns. To summarize our experiences gained by screening for vitamin B 12 deficiency. Clinical and laboratory data of vitamin B 12 -deficient infants diagnosed in Szeged Screening Centre were retrospectively analysed. In Hungary, expanded newborn screening was introduced in 2007. Since then approximately 395 000 newborns were screened in our centre and among them, we identified four newborns with vitamin B 12 deficiency based on their screening results. In three cases an elevated propionylcarnitine level and in the fourth one a low methionine level were indicative of vitamin B 12 deficiency. We also detected an additional vitamin B 12 -deficient infant with neurological symptoms at 4 months of age, after a normal newborn screening, because of elevated urinary methylmalonic acid concentration. Vitamin B 12 deficiency was secondary to maternal autoimmune pernicious anaemia in all the five infants. As a result of the recognized cases the incidence of infant vitamin B 12 deficiency in the East-Hungarian region was 1.26/100 000 births, but the real frequency may be higher. Conslusions: Optimizing the cut off values of current screening parameters and measuring of methylmalonic acid and/or homocysteine in the dried blood spot, as a second tier test, can improve recognition rate of vitamin B 12 deficiency. Orv Hetil. 2017; 158(48): 1909-1918.

  17. Diabetes Screening in US Women With a History of Gestational Diabetes, National Health and Nutrition Examination Survey, 2007-2012.

    PubMed

    Man, Bernice; Turyk, Mary E; Kominiarek, Michelle A; Xia, Yinglin; Gerber, Ben S

    2016-09-08

    Women with a history of gestational diabetes mellitus (GDM) are at increased risk for developing type 2 diabetes mellitus. We examined individual, socioeconomic, and health care use characteristics of women with a history of GDM and the association of those characteristics with diabetes screening, and we estimated their rates of undiagnosed prediabetes and diabetes. Using 3 cycles of the National Health and Nutrition Examination Survey (2007-2008, 2009-2010, and 2011-2012), we identified 284 women with a history of GDM who were eligible for diabetes screening. Screening status was defined by self-report of having had a blood test for diabetes within the prior 3 years. Undiagnosed prediabetes and diabetes were assessed by hemoglobin A1c measurement. Among women with a history of GDM, 67% reported diabetes screening within the prior 3 years. Weighted bivariate analyses showed screened women differed from unscreened women in measured body mass index (BMI) category (P = .01) and number of health visits in the prior year (P = .001). In multivariable analysis, screening was associated with a greater number of health visits in the prior year (1 visit vs 0 visits, adjusted odds ratio [AOR], 1.91; 95% confidence interval [CI], 0.71-5.18; 2 or 3 visits, AOR, 7.05; and ≥4 visits, AOR, 5.83). Overall, 24.4% (95% CI, 18.3%-31.7%) of women had undiagnosed prediabetes and 6.5% (95% CI, 3.7%-11.3%) had undiagnosed diabetes. More health visits in the prior year was associated with receiving diabetes screening. Fewer opportunities for screening may delay early detection, clinical management, and prevention of diabetes. Prediabetes in women with a history of GDM may be underrecognized and inadequately treated.

  18. Screening and confirmation capabilities of liquid chromatography-time-of-flight mass spectrometry for the determination of 200 multiclass sport drugs in urine.

    PubMed

    Domínguez-Romero, Juan C; García-Reyes, Juan F; Lara-Ortega, Felipe J; Molina-Díaz, Antonio

    2015-03-01

    In this article, a screening method for the determination of 200 sport drugs in human urine has been developed using liquid-chromatography electrospray time-of-flight mass spectrometry (LC-TOFMS). The chromatographic separation of the targeted doping agents was carried out by fast liquid chromatography using a C18 column (4.6×50 mm) with 1.8 μm particle size. Accurate mass measurements of the selected ion (typically [M+H](+) and [M-H](-)) along with retention time matching was used for the screening and detection of the targeted species. The proposed methodology comprised also a simple sample treatment stage based on solid-phase extraction (SPE) with polymeric cartridges. The SPE method displayed satisfactory recoveries rates (between 70 and 120%) for the majority of the compounds at both concentration levels tested (2.5 and 25 μg L(-1)). The overall performance of the method was satisfactory with all 200 compounds fulfilling WADA minimum required performance levels (MRPLs), with limits of quantitation lower than 1 μg L(-1) for 80% of the compounds, and showing an appropriate linearity (r(2)>0.99) in most cases. Additionally, the ability of "in-source" collision induced dissociation (CID) for confirmatory purposes was examined using as criterion the presence of two high-resolution ions with relevant abundances for unambiguous confirmation. This stringent criterion was fulfilled for 75% of the species using in-source CID fragmentation. The use of an improved approach based on CID performed on a dedicated collision cell without precursor ion selection (using a Q-TOF) provided at least two ions in all cases with the exception of 2-aminoheptane. Finally, based on the use of diagnostic fragment ions, a workflow for the comprehensive screening and identification of non-targeted compounds (viz. compounds with no primary standards or retention time information available, such as metabolites) has been also examined using rat urine samples. The proposed screening method has proved to be effective for the analysis of targeted compounds, and also for the identification of metabolites, expanding easily the search for doping agents not only limited to specific banned parent compounds but also to derivate compounds with similar structure as well as metabolites. Copyright © 2014 Elsevier B.V. All rights reserved.

  19. Nutritional Risk in Emergency-2017: A New Simplified Proposal for a Nutrition Screening Tool.

    PubMed

    Marcadenti, Aline; Mendes, Larissa Loures; Rabito, Estela Iraci; Fink, Jaqueline da Silva; Silva, Flávia Moraes

    2018-03-13

    There are many nutrition screening tools currently being applied in hospitals to identify risk of malnutrition. However, multivariate statistical models are not usually employed to take into account the importance of each variable included in the instrument's development. To develop and evaluate the concurrent and predictive validities of a new screening tool of nutrition risk. A prospective cohort study was developed, in which 4 nutrition screening tools were applied to all patients. Length of stay in hospital and mortality were considered to test the predictive validity, and the concurrent validity was tested by comparing the Nuritional Risk in Emergency (NRE)-2017 to the other tools. A total of 748 patients were included. The final NRE-2017 score was composed of 6 questions (advanced age, metabolic stress of the disease, decreased appetite, changing of food consistency, unintentional weight loss, and muscle mass loss) with answers yes or no. The prevalence of nutrition risk was 50.7% and 38.8% considering the cutoff points 1.0 and 1.5, respectively. The NRE-2017 showed a satisfactory power to indentify risk of malnutrition (area under the curve >0.790 for all analyses). According to the NRE-2017, patients at risk of malnutrition have twice as high relative risk of a very long hospital stay. The hazard ratio for mortality was 2.78 (1.03-7.49) when the cutoff adopted by the NRE-2017 was 1.5 points. NRE-2017 is a new, easy-to-apply nutrition screening tool which uses 6 bi-categoric features to detect the risk of malnutrition, and it presented a good concurrent and predictive validity. © 2018 American Society for Parenteral and Enteral Nutrition.

  20. Practical application of in silico fragmentation based residue screening with ion mobility high-resolution mass spectrometry.

    PubMed

    Kaufmann, Anton; Butcher, Patrick; Maden, Kathry; Walker, Stephan; Widmer, Mirjam

    2017-07-15

    A screening concept for residues in complex matrices based on liquid chromatography coupled to ion mobility high-resolution mass spectrometry LC/IMS-HRMS is presented. The comprehensive four-dimensional data (chromatographic retention time, drift time, mass-to-charge and ion abundance) obtained in data-independent acquisition (DIA) mode was used for data mining. An in silico fragmenter utilizing a molecular structure database was used for suspect screening, instead of targeted screening with reference substances. The utilized data-independent acquisition mode relies on the MS E concept; where two constantly alternating HRMS scans (low and high fragmentation energy) are acquired. Peak deconvolution and drift time alignment of ions from the low (precursor ion) and high (product ion) energy scan result in relatively clean product ion spectra. A bond dissociation in silico fragmenter (MassFragment) supplied with mol files of compounds of interest was used to explain the observed product ions of each extracted candidate component (chromatographic peak). Two complex matrices (fish and bovine liver extract) were fortified with 98 veterinary drugs. Out of 98 screened compounds 94 could be detected with the in silico based screening approach. The high correlation among drift time and m/z value of equally charged ions was utilized for an orthogonal filtration (ranking). Such an orthogonal ion mobility based filter removes multiply charged ions (e.g. peptides and proteins from the matrix) as well as noise and artefacts. Most significantly, this filtration dramatically reduces false positive findings but hardly increases false negative findings. The proposed screening approach may offer new possibilities for applications where reference compounds are hardly or not at all commercially available. Such areas may be the analysis of metabolites of drugs, pyrrolizidine alkaloids, marine toxins, derivatives of sildenafil or novel designer drugs (new psychoactive substances). Copyright © 2017 John Wiley & Sons, Ltd. Copyright © 2017 John Wiley & Sons, Ltd.

  1. Breast, prostate, and thyroid cancer screening tests and overdiagnosis.

    PubMed

    Jung, Minsoo

    The purpose of this study was to examine overdiagnosis and overtreatment related to cancer screening and to review relevant reports and studies. A comprehensive search of peer-reviewed and gray literature was conducted for relevant studies published between January 2000 and December 2015 reporting breast, prostate, and thyroid cancer screening tests and overdiagnosis. This study revealed no dichotomy on where screening would lower risk or cause overdiagnosis and overtreatment. Many screening tests did both, that is, at population level, there were both benefit (decreased disease-specific mortality) and harm (overdiagnosis and overtreatment). Therefore, we need to consider a balanced argument with citations for the potential benefits of screening along with the harms associated with screening. Although the benefits and harms can only be tested through randomized trials, important data from cohort studies, diagnostic accuracy studies, and modeling work can help define the extent of benefits and harms in the population. The health care cycle that prompt patients to undergo periodic screening tests is self-reinforcing. In most developed countries, screening test recommendations encourage periodic testing. Therefore, patients are continuing their screening. It is necessary for patients to become wise consumers of screening tests and make decisions with their physicians regarding further testing and treatments. Copyright © 2017 Elsevier Inc. All rights reserved.

  2. Hawking radiation from the holographic screen

    NASA Astrophysics Data System (ADS)

    Zhao, Ying-Jie

    2017-10-01

    In this paper, we generalize the Parikh-Wilczek scheme to a holographic screen in the framework of the ultraviolet self-complete quantum gravity. We calculate that the tunneling probability depends on the energy of the particle and the mass of the holographic screen. The radiating temperature has not been the standard Hawking temperature.

  3. EVALUATION OF GROUNDWATER FLOW PATTERNS AROUND A DUAL-SCREENED GROUNDWATER CIRCULATION WELL

    EPA Science Inventory

    Dual-screened groundwater circulation wells (GCWs) can be used to remove contaminant mass and to mix reagents in situ. GCWs are so named because they force water in a circular pattern between injection and extraction screens. The radial extent, flux and direction of the effective...

  4. Facilitating Factors and Barriers to BMI Screening in Schools

    ERIC Educational Resources Information Center

    Stalter, Ann M.; Chaudry, Rosemary V.; Polivka, Barbara J.

    2010-01-01

    The National Association of School Nurses advocates for body mass index (BMI) screening. Little research describes school nurse practice of BMI screening. In this descriptive study, 25 Ohio school nurses participated in three focus groups. An adapted "Healthy People 2010" Determinants of Health Model guided the research questions. School…

  5. Computer-aided diagnosis workstation and telemedicine network system for chest diagnosis based on multislice CT images

    NASA Astrophysics Data System (ADS)

    Satoh, Hitoshi; Niki, Noboru; Eguchi, Kenji; Ohmatsu, Hironobu; Kakinuma, Ryutaru; Moriyama, Noriyuki

    2009-02-01

    Mass screening based on multi-helical CT images requires a considerable number of images to be read. It is this time-consuming step that makes the use of helical CT for mass screening impractical at present. Moreover, the doctor who diagnoses a medical image is insufficient in Japan. To overcome these problems, we have provided diagnostic assistance methods to medical screening specialists by developing a lung cancer screening algorithm that automatically detects suspected lung cancers in helical CT images, a coronary artery calcification screening algorithm that automatically detects suspected coronary artery calcification and a vertebra body analysis algorithm for quantitative evaluation of osteoporosis likelihood by using helical CT scanner for the lung cancer mass screening. The functions to observe suspicious shadow in detail are provided in computer-aided diagnosis workstation with these screening algorithms. We also have developed the telemedicine network by using Web medical image conference system with the security improvement of images transmission, Biometric fingerprint authentication system and Biometric face authentication system. Biometric face authentication used on site of telemedicine makes "Encryption of file" and "Success in login" effective. As a result, patients' private information is protected. We can share the screen of Web medical image conference system from two or more web conference terminals at the same time. An opinion can be exchanged mutually by using a camera and a microphone that are connected with workstation. Based on these diagnostic assistance methods, we have developed a new computer-aided workstation and a new telemedicine network that can display suspected lesions three-dimensionally in a short time. The results of this study indicate that our radiological information system without film by using computer-aided diagnosis workstation and our telemedicine network system can increase diagnostic speed, diagnostic accuracy and security improvement of medical information.

  6. Whole organism high content screening identifies stimulators of pancreatic beta-cell proliferation.

    PubMed

    Tsuji, Naoki; Ninov, Nikolay; Delawary, Mina; Osman, Sahar; Roh, Alex S; Gut, Philipp; Stainier, Didier Y R

    2014-01-01

    Inducing beta-cell mass expansion in diabetic patients with the aim to restore glucose homeostasis is a promising therapeutic strategy. Although several in vitro studies have been carried out to identify modulators of beta-cell mass expansion, restoring endogenous beta-cell mass in vivo has yet to be achieved. To identify potential stimulators of beta-cell replication in vivo, we established transgenic zebrafish lines that monitor and allow the quantification of cell proliferation by using the fluorescent ubiquitylation-based cell cycle indicator (FUCCI) technology. Using these new reagents, we performed an unbiased chemical screen, and identified 20 small molecules that markedly increased beta-cell proliferation in vivo. Importantly, these structurally distinct molecules, which include clinically-approved drugs, modulate three specific signaling pathways: serotonin, retinoic acid and glucocorticoids, showing the high sensitivity and robustness of our screen. Notably, two drug classes, retinoic acid and glucocorticoids, also promoted beta-cell regeneration after beta-cell ablation. Thus, this study establishes a proof of principle for a high-throughput small molecule-screen for beta-cell proliferation in vivo, and identified compounds that stimulate beta-cell proliferation and regeneration.

  7. Detection of weapons of mass destruction

    NASA Astrophysics Data System (ADS)

    Bjorkholm, Paul J.

    2003-07-01

    High Energy X-ray cargo screening is a mature technology that has proven its value in the detection of contraband material hidden within cargo including fully loaded sea containers. To date high energy screening has been largely applied to manifest verification and to drug detection. However, the dramatic change in world terrorism has altered the application. Now it is essential that weapons of mass destruction (WMD"s) be interdicted with incredibly high accuracy. The implication of a missed detection has gone from loss of revenue or the lowering of the street price of drugs to potentially stopping, at least for some significant time, most world commerce. Screening containers with high energy x-rays (~250+ mm of steel penetration) is capable of detecting all nuclear threats at a fraction of the strategically important mass. The screening operation can be automated so that no human decisions are required with very low false alarms. Finally, the goal of 100% inspection of cargo inbound to the United States from the twenty largest international ports is an achievable goal with hardware costs in the area of that already spent on airport security.

  8. [Evaluation of mass screening activity for cardiovascular disease risk factors in a rural environment].

    PubMed

    Boudreau, F

    2001-01-01

    The aim of this study was to evaluate the immediate and short-term impacts of a cardiovascular mass screening activity in a rural environment. A posttest-only control group design was used. Concerning the immediate impact, the results showed that the participants of the experimental group had, compared to the participants in the control group, a higher intention to participate regularly in physical activities and a higher intention to reduce their fat consumption. The participants' intention to stop smoking was not modified by the screening activity. After four months, the results revealed an increase in participation in physical activities and a decrease in fat consumption. The proportion of participants who smoked did not decrease. In conclusion, it is suggested that a cardiovascular mass screening activity such as the one performed in this study could be effective in motivating a population to adopt heart health-related behaviours. Others studies are necessary however to confirm the short-term impact of this type of activity on behaviour modification with regard to cardiovascular health.

  9. Cancer Screening: How Do Screening Tests Become Standard Tests?

    MedlinePlus

    ... more groups. The people in one group (the control group ) may be given a standard screening test (if one exists) or no screening test. The ... for the human papillomavirus (HPV) and those who test negative for HPV. The ... Case-control studies Case-control studies are like cohort studies ...

  10. Added value of shear-wave elastography for evaluation of breast masses detected with screening US imaging.

    PubMed

    Lee, Su Hyun; Chang, Jung Min; Kim, Won Hwa; Bae, Min Sun; Seo, Mirinae; Koo, Hye Ryoung; Chu, A Jung; Gweon, Hye Mi; Cho, Nariya; Moon, Woo Kyung

    2014-10-01

    To evaluate the additional value of shear-wave elastography (SWE) to B-mode ultrasonography (US) and to determine an appropriate guideline for the combined assessment of screening US-detected breast masses. This study was conducted with institutional review board approval, and written informed consent was obtained. From March 2010 to February 2012, B-mode US and SWE were performed in 159 US-detected breast masses before biopsy. For each lesion, Breast Imaging Reporting and Data System (BI-RADS) category on B-mode US images and the maximum stiffness color and elasticity values on SWE images were assessed. A guideline for adding SWE data to B-mode US was developed with the retrospective cohort to improve diagnostic performance in sensitivity and specificity and was validated in a distinct prospective cohort of 207 women prior to biopsy. Twenty-one of 159 masses in the development cohort and 12 of 207 breast masses in the validation cohort were malignant. In the development cohort, when BI-RADS category 4a masses showing a dark blue color or a maximum elasticity value of 30 kPa or less on SWE images were downgraded to category 3, specificity increased from 9.4% (13 of 138) to 59.4% (82 of 138) and 57.2% (79 of 138) (P < .001), respectively, without loss in sensitivity (100% [21 of 21]). In the validation cohort, specificity increased from 17.4% (34 of 195) to 62.1% (121 of 195) and 53.3% (104 of 195) (P < .001) respectively, without loss in sensitivity (91.7% [11 of 12]). The addition of SWE to B-mode US improved diagnostic performance with increased specificity for screening US-detected breast masses. BI-RADS category 4a masses detected at US screening that showed a dark blue color or a maximum elasticity value of 30 kPa or less on SWE images can be safely followed up instead of performing biopsy. © RSNA, 2014.

  11. Improving compliance to colorectal cancer screening using blood and stool based tests in patients refusing screening colonoscopy in Germany.

    PubMed

    Adler, Andreas; Geiger, Sebastian; Keil, Anne; Bias, Harald; Schatz, Philipp; deVos, Theo; Dhein, Jens; Zimmermann, Mathias; Tauber, Rudolf; Wiedenmann, Bertram

    2014-10-17

    Despite strong recommendations for colorectal cancer (CRC) screening, participation rates are low. Understanding factors that affect screening choices is essential to developing future screening strategies. Therefore, this study assessed patient willingness to use non-invasive stool or blood based screening tests after refusing colonoscopy. Participants were recruited during regular consultations. Demographic, health, psychological and socioeconomic factors were recorded. All subjects were advised to undergo screening by colonoscopy. Subjects who refused colonoscopy were offered a choice of non-invasive tests. Subjects who selected stool testing received a collection kit and instructions; subjects who selected plasma testing had a blood draw during the office visit. Stool samples were tested with the Hb/Hp Complex Elisa test, and blood samples were tested with the Epi proColon® 2.0 test. Patients who were positive for either were advised to have a diagnostic colonoscopy. 63 of 172 subjects were compliant to screening colonoscopy (37%). 106 of the 109 subjects who refused colonoscopy accepted an alternative non-invasive method (97%). 90 selected the Septin9 blood test (83%), 16 selected a stool test (15%) and 3 refused any test (3%). Reasons for blood test preference included convenience of an office draw, overall convenience and less time consuming procedure. 97% of subjects refusing colonoscopy accepted a non-invasive screening test of which 83% chose the Septin9 blood test. The observation that participation can be increased by offering non-invasive tests, and that a blood test is the preferred option should be validated in a prospective trial in the screening setting.

  12. Development and validation of a fast and simple multi-analyte procedure for quantification of 40 drugs relevant to emergency toxicology using GC-MS and one-point calibration.

    PubMed

    Meyer, Golo M J; Weber, Armin A; Maurer, Hans H

    2014-05-01

    Diagnosis and prognosis of poisonings should be confirmed by comprehensive screening and reliable quantification of xenobiotics, for example by gas chromatography-mass spectrometry (GC-MS) or liquid chromatography-mass spectrometry (LC-MS). The turnaround time should be short enough to have an impact on clinical decisions. In emergency toxicology, quantification using full-scan acquisition is preferable because this allows screening and quantification of expected and unexpected drugs in one run. Therefore, a multi-analyte full-scan GC-MS approach was developed and validated with liquid-liquid extraction and one-point calibration for quantification of 40 drugs relevant to emergency toxicology. Validation showed that 36 drugs could be determined quickly, accurately, and reliably in the range of upper therapeutic to toxic concentrations. Daily one-point calibration with calibrators stored for up to four weeks reduced workload and turn-around time to less than 1 h. In summary, the multi-analyte approach with simple liquid-liquid extraction, GC-MS identification, and quantification over fast one-point calibration could successfully be applied to proficiency tests and real case samples. Copyright © 2013 John Wiley & Sons, Ltd.

  13. Weight-for-length/height growth curves for children and adolescents in China in comparison with body mass index in prevalence estimates of malnutrition.

    PubMed

    Zong, Xinnan; Li, Hui; Zhang, Yaqin; Wu, Huahong

    2017-05-01

    It is important to update weight-for-length/height growth curves in China and re-examine their performance in screening malnutrition. To develop weight-for-length/height growth curves for Chinese children and adolescents. A total of 94 302 children aged 0-19 years with complete sex, age, weight and length/height data were obtained from two cross-sectional large-scaled national surveys in China. Weight-for-length/height growth curves were constructed using the LMS method before and after average spermarcheal/menarcheal ages, respectively. Screening performance in prevalence estimates of wasting, overweight and obesity was compared between weight-for-height and body mass index (BMI) criteria based on a test population of 21 416 children aged 3-18. The smoothed weight-for-length percentiles and Z-scores growth curves with length 46-110 cm for both sexes and weight-for-height with height 70-180 cm for boys and 70-170 cm for girls were established. The weight-for-height and BMI-for-age had strong correlation in screening wasting, overweight and obesity in each age-sex group. There was no striking difference in prevalence estimates of wasting, overweight and obesity between two indicators except for obesity prevalence at ages 6-11. This set of smoothed weight-for-length/height growth curves may be useful in assessing nutritional status from infants to post-pubertal adolescents.

  14. Development of a new screening method for the detection of antibiotic residues in muscle tissues using liquid chromatography and high resolution mass spectrometry with a LC-LTQ-Orbitrap instrument.

    PubMed

    Hurtaud-Pessel, D; Jagadeshwar-Reddy, T; Verdon, E

    2011-10-01

    A liquid chromatography-high resolution mass spectrometry (LC-HRMS) method was developed for screening meat for a wide range of antibiotics used in veterinary medicine. Full-scan mode under high resolution mass spectral conditions using an LTQ-Orbitrap mass spectrometer with resolving power 60,000 full width at half maximum (FWHM) was applied for analysis of the samples. Samples were prepared using two extraction protocols prior to LC-HRMS analysis. The scope of the method focuses on screening the following main families of antibacterial veterinary drugs: penicillins, cephalosporins, sulfonamides, macrolides, tetracyclines, aminoglucosides and quinolones. Compounds were successfully identified in spiked samples from their accurate mass and LC retention times from the acquired full-scan chromatogram. Automated data processing using ToxId software allowed rapid treatment of the data. Analyses of muscle tissues from real samples collected from antibiotic-treated animals was carried out using the above methodology and antibiotic residues were identified unambiguously. Further analysis of the data for real samples allowed the identification of the targeted antibiotic residues but also non-targeted compounds, such as some of their metabolites.

  15. Broad screening of illicit ingredients in cosmetics using ultra-high-performance liquid chromatography-hybrid quadrupole-Orbitrap mass spectrometry with customized accurate-mass database and mass spectral library.

    PubMed

    Meng, Xianshuang; Bai, Hua; Guo, Teng; Niu, Zengyuan; Ma, Qiang

    2017-12-15

    Comprehensive identification and quantitation of 100 multi-class regulated ingredients in cosmetics was achieved using ultra-high-performance liquid chromatography (UHPLC) coupled with hybrid quadrupole-Orbitrap high-resolution mass spectrometry (Q-Orbitrap HRMS). A simple, efficient, and inexpensive sample pretreatment protocol was developed using ultrasound-assisted extraction (UAE), followed by dispersive solid-phase extraction (dSPE). The cosmetic samples were analyzed by UHPLC-Q-Orbitrap HRMS under synchronous full-scan MS and data-dependent MS/MS (full-scan MS 1 /dd-MS 2 ) acquisition mode. The mass resolution was set to 70,000 FWHM (full width at half maximum) for full-scan MS 1 and 17,500 FWHM for dd-MS 2 stage with the experimentally measured mass deviations of less than 2ppm (parts per million) for quasi-molecular ions and 5ppm for characteristic fragment ions for each individual analyte. An accurate-mass database and a mass spectral library were built in house for searching the 100 target compounds. Broad screening was conducted by comparing the experimentally measured exact mass of precursor and fragment ions, retention time, isotopic pattern, and ionic ratio with the accurate-mass database and by matching the acquired MS/MS spectra against the mass spectral library. The developed methodology was evaluated and validated in terms of limits of detection (LODs), limits of quantitation (LOQs), linearity, stability, accuracy, and matrix effect. The UHPLC-Q-Orbitrap HRMS approach was applied for the analysis of 100 target illicit ingredients in 123 genuine cosmetic samples, and exhibited great potential for high-throughput, sensitive, and reliable screening of multi-class illicit compounds in cosmetics. Copyright © 2017 Elsevier B.V. All rights reserved.

  16. Liquid Oxygen/Liquid Methane Propulsion and Cryogenic Advanced Development

    NASA Technical Reports Server (NTRS)

    Klem, Mark D.; Smith, Timothy D.; Wadel, Mary F.; Meyer, Michael L.; Free, James M.; Cikanek, Harry A., III

    2011-01-01

    Exploration Systems Architecture Study conducted by NASA in 2005 identified the liquid oxygen (LOx)/liquid methane (LCH4) propellant combination as a prime candidate for the Crew Exploration Vehicle Service Module propulsion and for later use for ascent stage propulsion of the lunar lander. Both the Crew Exploration Vehicle and Lunar Lander were part the Constellation architecture, which had the objective to provide global sustained lunar human exploration capability. From late 2005 through the end of 2010, NASA and industry matured advanced development designs for many components that could be employed in relatively high thrust, high delta velocity, pressure fed propulsion systems for these two applications. The major investments were in main engines, reaction control engines, and the devices needed for cryogenic fluid management such as screens, propellant management devices, thermodynamic vents, and mass gauges. Engine and thruster developments also included advanced high reliability low mass igniters. Extensive tests were successfully conducted for all of these elements. For the thrusters and engines, testing included sea level and altitude conditions. This advanced development provides a mature technology base for future liquid oxygen/liquid methane pressure fed space propulsion systems. This paper documents the design and test efforts along with resulting hardware and test results.

  17. Adherence to multiple cancer screening tests among women living in Appalachia Ohio

    PubMed Central

    Katz, Mira L.; Reiter, Paul L.; Young, Gregory S.; Pennell, Michael L.; Tatum, Cathy M.; Paskett, Electra D.

    2015-01-01

    Background There is a lack of information about the correlates of completing all three cancer screening tests among women living in Appalachia. Methods Cross-sectional telephone interviews were conducted (April-September 2013) among women (n=637) ages 51-75 from 12 Appalachia Ohio counties. Outcomes of within screening guidelines were verified by medical record. Multivariable logistic regression models identified correlates of being within guidelines for all three cancer screening tests. Results Screening rates were: mammography (32.1%), Pap test (36.1%), and a colorectal cancer test (30.1%). Only 8.6% of women were within guidelines for all tests. Having had a check-up in the past two years and having received a screening recommendation were significantly related to being within guidelines for all three tests (p<0.01). Participants with higher annual household incomes ($60,000+; OR=3.53, 95% CI: 1.49, 8.33) and conditions requiring regular medical visits (OR=3.16, 95% CI: 1.29, 7.74) were more likely to be within guidelines for all three screening tests. Conclusion Less than 10% of women had completed screening within guidelines for all three screening tests. Regular contact with the healthcare system and higher incomes were significant predictors of being within guidelines. Impact Within guidelines rates for the three recommended cancer screening tests is low among women in Appalachia Ohio. This finding illustrates the need for innovative interventions to improve rates of multiple cancer screening tests. PMID:26282630

  18. Validation of a nutrition risk screening tool for children and adolescents with cystic fibrosis ages 2-20 years.

    PubMed

    McDonald, Catherine M

    2008-04-01

    According to the 2002 Cystic Fibrosis (CF) Foundation nutrition consensus report, children with CF should grow normally. Cross-sectional data from the foundation's patient registry concluded that a body mass index at or greater than the 50th percentile is associated with better lung function. A consistent, evidence-based screening process can identify those individuals with CF having nutrition risk factors associated with a decrease in pulmonary function, target early intervention, and prevent further decline. A tool for screening nutrition risk is described to identify those children with CF who would benefit from more extensive nutrition intervention. The proposed screening tool is a risk-based classification system with 3 categories: weight gain, height velocity, and body mass index. The CF Foundation recommendations regarding these parameters are incorporated, with risk points assigned when minimum body mass index, weight gain, and/or height gain standards are unmet. An interrater measure of agreement determined a satisfactory level of reliability (kappa = 0.85). Patient records (n = 85) were reviewed to determine nutrition status category (no risk or at risk) of this tool compared with the CF Foundation 2002 Nutrition Consensus, yielding sensitivity and specificity at 84% and 75%, respectively. A second comparison was made with combined, independent nutrition risk factors not included in the screening tool. The sensitivity and specificity of the screening tool compared with the combined risk factors were 86% and 78%, respectively. This tool for screening nutrition risk for CF is reliable and valid, with consistent, reproducible results, free from subject or observer bias.

  19. Breast masses in mammography classification with local contour features.

    PubMed

    Li, Haixia; Meng, Xianjing; Wang, Tingwen; Tang, Yuchun; Yin, Yilong

    2017-04-14

    Mammography is one of the most popular tools for early detection of breast cancer. Contour of breast mass in mammography is very important information to distinguish benign and malignant mass. Contour of benign mass is smooth and round or oval, while malignant mass has irregular shape and spiculated contour. Several studies have shown that 1D signature translated from 2D contour can describe the contour features well. In this paper, we propose a new method to translate 2D contour of breast mass in mammography into 1D signature. The method can describe not only the contour features but also the regularity of breast mass. Then we segment the whole 1D signature into different subsections. We extract four local features including a new contour descriptor from the subsections. The new contour descriptor is root mean square (RMS) slope. It can describe the roughness of the contour. KNN, SVM and ANN classifier are used to classify benign breast mass and malignant mass. The proposed method is tested on a set with 323 contours including 143 benign masses and 180 malignant ones from digital database of screening mammography (DDSM). The best accuracy of classification is 99.66% using the feature of root mean square slope with SVM classifier. The performance of the proposed method is better than traditional method. In addition, RMS slope is an effective feature comparable to most of the existing features.

  20. Validated semiquantitative/quantitative screening of 51 drugs in whole blood as silylated derivatives by gas chromatography-selected ion monitoring mass spectrometry and gas chromatography electron capture detection.

    PubMed

    Gunnar, Teemu; Mykkänen, Sirpa; Ariniemi, Kari; Lillsunde, Pirjo

    2004-07-05

    A comprehensively validated procedure is presented for simultaneous semiquantitative/quantitative screening of 51 drugs of abuse or drugs potentially hazardous for traffic safety in serum, plasma or whole blood. Benzodiazepines (12), cannabinoids (3), opioids (8), cocaine, antidepressants (13), antipsychotics (5) and antiepileptics (2) as well as zolpidem, zaleplon, zopiclone, meprobamate, carisoprodol, tizanidine and orphenadrine and internal standard flurazepam, were isolated by high-yield liquid-liquid extraction (LLE). The dried extracts were derivatized by two-step silylation and analyzed by the combination of two different gas chromatographic (GC) separations with both electron capture detection (ECD) and mass spectrometry (MS) operating in a selected ion-monitoring (SIM) mode. Quantitative or semiquantitative results were obtained for each substance based on four-point calibration. In the validation tests, accuracy, reproducibility, linearity, limit of detection (LOD) and limit of quantitation (LOQ), selectivity, as well as extraction efficiency and stability of standard stock solutions were tested, and derivatization was optimized in detail. Intra- and inter-day precisions were within 2.5-21.8 and 6.0-22.5%, and square of correlation coefficients of linearity ranged from 0.9896 to 0.9999. The limit of quantitation (LOQ) varied from 2 to 2000 ng/ml due to a variety of the relevant concentrations of the analyzed substances in blood. The method is feasible for highly sensitive, reliable and possibly routinely performed clinical and forensic toxicological analyses.

  1. Urinary metabotyping of bladder cancer using two-dimensional gas chromatography time-of-flight mass spectrometry.

    PubMed

    Pasikanti, Kishore Kumar; Esuvaranathan, Kesavan; Hong, Yanjun; Ho, Paul C; Mahendran, Ratha; Raman Nee Mani, Lata; Chiong, Edmund; Chan, Eric Chun Yong

    2013-09-06

    Cystoscopy is the gold standard clinical diagnosis of human bladder cancer (BC). As cystoscopy is expensive and invasive, it compromises patients' compliance toward surveillance screening and challenges the detection of recurrent BC. Therefore, the development of a noninvasive method for the diagnosis and surveillance of BC and the elucidation of BC progression become pertinent. In this study, urine samples from 38 BC patients and 61 non-BC controls were subjected to urinary metabotyping using two-dimensional gas chromatography time-of-flight mass spectrometry (GC×GC-TOFMS). Subsequent to data preprocessing and chemometric analysis, the orthogonal partial least-squares discriminant analysis (OPLS-DA, R2X=0.278, R2Y=0.904 and Q2Y (cumulative)=0.398) model was validated using permutation tests and receiver operating characteristic (ROC) analysis. Marker metabolites were further screened from the OPLS-DA model using statistical tests. GC×GC-TOFMS urinary metabotyping demonstrated 100% specificity and 71% sensitivity in detecting BC, while 100% specificity and 46% sensitivity were observed via cytology. In addition, the model revealed 46 metabolites that characterize human BC. Among the perturbed metabolic pathways, our clinical finding on the alteration of the tryptophan-quinolinic metabolic axis in BC suggested the potential roles of kynurenine in the malignancy and therapy of BC. In conclusion, global urinary metabotyping holds potential for the noninvasive diagnosis and surveillance of BC in clinics. In addition, perturbed metabolic pathways gleaned from urinary metabotyping shed new and established insights on the biology of human BC.

  2. Incorporating DNA Sequencing into Current Prenatal Screening Practice for Down's Syndrome

    PubMed Central

    Wald, Nicholas J.; Bestwick, Jonathan P.

    2013-01-01

    Background Prenatal screening for Down's syndrome is performed using biochemical and ultrasound markers measured in early pregnancy such as the Integrated test using first and second trimester markers. Recently, DNA sequencing methods have been introduced on free DNA in maternal plasma, yielding a high screening performance. These methods are expensive and there is a test failure rate. We determined the screening performance of merging the Integrated test with the newer DNA techniques in a protocol that substantially reduces the cost compared with universal DNA testing and still achieves high screening performance with no test failures. Methods Published data were used to model screening performance of a protocol in which all women receive the first stage of the Integrated test at about 11 weeks of pregnancy. On the basis of this higher risk women have reflex DNA testing and lower risk women as well as those with a failed DNA test complete the Integrated test at about 15 weeks. Results The overall detection rate was 95% with a 0.1% false-positive rate if 20% of women were selected to receive DNA testing. If all women had DNA testing the detection rate would be 3 to 4 percentage points higher with a false-positive rate 30 times greater if women with failed tests were treated as positive and offered a diagnostic amniocentesis, or 3 times greater if they had a second trimester screening test (Quadruple test) and treated as positive only if this were positive. The cost per women screened would be about one-fifth, compared with universal DNA testing, if the DNA test were 20 times the cost of the Integrated test. Conclusion The proposed screening protocol achieves a high screening performance without programme test failures and at a substantially lower cost than offering all women DNA testing. PMID:23527014

  3. Is maternal plasma DNA testing impacting serum-based screening for aneuploidy in the United States?

    PubMed

    Palomaki, Glenn E; Ashwood, Edward R; Best, Robert G; Lambert-Messerlian, Geralyn; Knight, George J

    2015-11-01

    We sought to determine whether tests for fetal aneuploidy based on next-generation sequencing of cell-free DNA in maternal circulation have had an impact on routine serum-based screening in the general pregnant population. We compared results from laboratory surveys in 2011 and 2014 that reported types of prenatal serum screening tests and numbers of tests performed. Testing records from two prenatal serum screening laboratories examined temporal trends in the proportion of screened women 35 years of age and older from 2008 (or 2009) to 2014. The 82 laboratory survey results available for comparison showed that 1.7 million women were screened in 2014, a 5% increase over 2011. In the two screening laboratories, the proportion of screened women age 35 and older increased for several years but then experienced reductions of 8 and 18% by mid-2014 when compared with the highest rates observed. As of 2014, maternal plasma DNA testing appears to have had only a minor impact on serum screening rates in the United States. Ongoing surveillance has the potential to determine if, and when, DNA testing begins to replace serum testing as a primary screen for Down syndrome in the United States.

  4. Screening for trace explosives by AccuTOF™-DART®: an in-depth validation study.

    PubMed

    Sisco, Edward; Dake, Jeffrey; Bridge, Candice

    2013-10-10

    Ambient ionization mass spectrometry is finding increasing utility as a rapid analysis technique in a number of fields. In forensic science specifically, analysis of many types of samples, including drugs, explosives, inks, bank dye, and lotions, has been shown to be possible using these techniques [1]. This paper focuses on one type of ambient ionization mass spectrometry, Direct Analysis in Real Time Mass Spectrometry (DART-MS or DART), and its viability as a screening tool for trace explosives analysis. In order to assess viability, a validation study was completed which focused on the analysis of trace amounts of nitro and peroxide based explosives. Topics which were studied, and are discussed, include method optimization, reproducibility, sensitivity, development of a search library, discrimination of mixtures, and blind sampling. Advantages and disadvantages of this technique over other similar screening techniques are also discussed. Copyright © 2013 Elsevier Ireland Ltd. All rights reserved.

  5. Rapid screening of pharmaceutical drugs using thermal desorption - SALDI mass spectrometry

    NASA Astrophysics Data System (ADS)

    Grechnikov, A. A.; Kubasov, A. E.; Georgieva, V. B.; Borodkov, A. S.; Nikiforov, S. M.; Simanovsky, Ya O.; Alimpiev, S. S.

    2012-12-01

    A novel approach to the rapid screening of pharmaceutical drugs by surface assisted laser desorption-ionization (SALDI) mass spectrometry with the rotating ball interface coupled with temperature programmed thermal desorption has been developed. Analytes were thermally desorbed and deposited onto the surface of amorphous silicon substrate attached to the rotating ball. The ball was rotated and the deposited analytes were analyzed using SALDI. The effectiveness of coupling SALDI mass spectrometry with thermal desorption was evaluated by the direct and rapid analysis of tablets containing lidocaine, diphenhydramine and propranolol without any sample pretreatment. The overall duration of the screening procedure was 30÷40 sec. Real urine samples were studied for drug analysis. It is shown that with simple preparation steps, urine samples can be quantitatively analyzed using the proposed technique with the detection limits in the range of 0.2÷0.5 ng/ml.

  6. High impact technologies for natural products screening.

    PubMed

    Koehn, Frank E

    2008-01-01

    Natural products have historically been a rich source of lead molecules in drug discovery. However, natural products have been de-emphasized as high throughput screening resources in the recent past, in part because of difficulties in obtaining high quality natural products screening libraries, or in applying modern screening assays to these libraries. In addition, natural products programs based on screening of extract libraries, bioassay-guided isolation, structure elucidation and subsequent production scale-up are challenged to meet the rapid cycle times that are characteristic of the modern HTS approach. Fortunately, new technologies in mass spectrometry, NMR and other spectroscopic techniques can greatly facilitate the first components of the process - namely the efficient creation of high-quality natural products libraries, bimolecular target or cell-based screening, and early hit characterization. The success of any high throughput screening campaign is dependent on the quality of the chemical library. The construction and maintenance of a high quality natural products library, whether based on microbial, plant, marine or other sources is a costly endeavor. The library itself may be composed of samples that are themselves mixtures - such as crude extracts, semi-pure mixtures or single purified natural products. Each of these library designs carries with it distinctive advantages and disadvantages. Crude extract libraries have lower resource requirements for sample preparation, but high requirements for identification of the bioactive constituents. Pre-fractionated libraries can be an effective strategy to alleviate interferences encountered with crude libraries, and may shorten the time needed to identify the active principle. Purified natural product libraries require substantial resources for preparation, but offer the advantage that the hit detection process is reduced to that of synthetic single component libraries. Whether the natural products library consists of crude or partially fractionated mixtures, the library contents should be profiled to identify the known components present - a process known as dereplication. The use of mass spectrometry and HPLC-mass spectrometry together with spectral databases is a powerful tool in the chemometric profiling of bio-sources for natural product production. High throughput, high sensitivity flow NMR is an emerging tool in this area as well. Whether by cell based or biomolecular target based assays, screening of natural product extract libraries continues to furnish novel lead molecules for further drug development, despite challenges in the analysis and prioritization of natural products hits. Spectroscopic techniques are now being used to directly screen natural product and synthetic libraries. Mass spectrometry in the form of methods such as ESI-ICRFTMS, and FACS-MS as well as NMR methods such as SAR by NMR and STD-NMR have been utilized to effectively screen molecular libraries. Overall, emerging advances in mass spectrometry, NMR and other technologies are making it possible to overcome the challenges encountered in screening natural products libraries in today's drug discovery environment. As we apply these technologies and develop them even further, we can look forward to increased impact of natural products in the HTS based drug discovery.

  7. Testing and screening for chlamydia in general practice: a cross-sectional analysis.

    PubMed

    Thomson, Allison; Morgan, Simon; Henderson, Kim; Tapley, Amanda; Spike, Neil; Scott, John; van Driel, Mieke; Magin, Parker

    2014-12-01

    Chlamydia screening is widely advocated. General practice registrars are an important stage of clinical behaviour development. This study aimed to determine rates of, and factors associated with, registrars' chlamydia testing including asymptomatic screening. A cross-sectional analysis of data from Registrars Clinical Encounters in Training (ReCEnT), a cohort study of registrars' consultations. Registrars record details of 60 consecutive consultations in each GP-term of training. Outcome factors were chlamydia testing, asymptomatic screening and doctor-initiated screening. Testing occurred in 2.5% of 29,112 consultations (398 registrars) and in 5.8% of patients aged 15-25. Asymptomatic screening comprised 47.5% of chlamydia tests, and 55.6% of screening tests were doctor-initiated. Chlamydia testing was associated with female gender of doctor and patient, younger patient age, and patients new to doctor or practice. Asymptomatic screening was associated with practices where patients incur no fees, and in patients new to doctor or practice. Screening of female patients was more often doctor-initiated. GP registrars screen for chlamydia disproportionately in younger females and new patients. Our findings highlight potential opportunities to improve uptake of screening for chlamydia, including targeted education and training for registrars, campaigns targeting male patients, and addressing financial barriers to accessing screening services. © 2014 Public Health Association of Australia.

  8. The effect of presenting information about invasive follow-up testing on individuals' noninvasive colorectal cancer screening participation decision: results from a discrete choice experiment.

    PubMed

    Benning, Tim M; Dellaert, Benedict G C; Severens, Johan L; Dirksen, Carmen D

    2014-07-01

    Many national colorectal cancer screening campaigns have a similar structure. First, individuals are invited to take a noninvasive screening test, and, second, in the case of a positive screening test result, they are advised to undergo a more invasive follow-up test. The objective of this study was to investigate how much individuals' participation decision in noninvasive screening is affected by the presence or absence of detailed information about invasive follow-up testing and how this effect varies over screening tests. We used a labeled discrete choice experiment of three noninvasive colorectal cancer screening types with two versions that did or did not present respondents with detailed information about the possible invasive follow-up test (i.e., colonoscopy) and its procedure. We used data from 631 Dutch respondents aged 55 to 75 years. Each respondent received only one of the two versions (N = 310 for the invasive follow-up test information specification version, and N = 321 for the no-information specification version). Mixed logit model results show that detailed information about the invasive follow-up test negatively affects screening participation decisions. This effect can be explained mainly by a decrease in choice shares for the most preferred screening test (a combined stool and blood sample test). Choice share simulations based on the discrete choice experiment indicated that presenting invasive follow-up test information decreases screening participation by 4.79%. Detailed information about the invasive follow-up test has a negative effect on individuals' screening participation decisions in noninvasive colorectal cancer screening campaigns. This result poses new challenges for policymakers who aim not only to increase uptake but also to provide full disclosure to potential screening participants. Copyright © 2014 International Society for Pharmacoeconomics and Outcomes Research (ISPOR). Published by Elsevier Inc. All rights reserved.

  9. Abnormal Cervical Cancer Screening Test Results

    MedlinePlus

    ... FAQ187 GYNECOLOGIC PROBLEMS Abnormal Cervical Cancer Screening Test Results • What is cervical cancer screening? • What causes abnormal cervical cancer screening test results? • What is the difference between the terms cervical ...

  10. Uncommon presentation of a rare tumour - incidental finding in an asymptomatic patient: case report and comprehensive review of the literature on intrapericardial solitary fibrous tumours.

    PubMed

    Czimbalmos, Csilla; Csecs, Ibolya; Polos, Miklos; Bartha, Elektra; Szucs, Nikolette; Toth, Attila; Maurovich-Horvat, Pal; Becker, David; Sapi, Zoltan; Szabolcs, Zoltan; Merkely, Bela; Vago, Hajnalka

    2017-09-02

    A solitary fibrous tumour is a rare, mainly benign spindle cell mesenchymal tumour most commonly originating from the pleura. An intrapericardial location of a solitary fibrous tumour is extremely unusual. We present a case of an asymptomatic patient with a slow-growing massive benign cardiac solitary fibrous tumour. A 37-year-old asymptomatic female patient was referred to our hospital with an enlarged cardiac silhouette found on her screening chest X-ray. The echocardiographic examination revealed pericardial effusion and an inhomogeneous mobile mass located in the pericardial sac around the left ventricle. Cardiac magnetic resonance (MRI) examination showed an intrapericardial, semilunar-shaped mass attached to the pulmonary trunk with an intermediate signal intensity on proton density-weighted images and high signal intensity on T2-weighted spectral fat saturation inversion recovery images. First-pass perfusion and early and late gadolinium-enhanced images showed a vascularized mass with septated, patchy, inhomogeneous late enhancement. Coronary computed tomography angiography revealed no invasion of the coronaries. Based on the retrospectively analysed screening chest X-rays, the mass had started to form at least 7 years earlier. Complete resection of the tumour with partial resection of the pulmonary trunk was performed. Histological evaluation of the septated, cystic mass revealed tumour cells forming an irregular patternless pattern; immunohistochemically, the cells tested positive for vimentin, CD34, CD99 and STAT6 but negative for keratin (AE1-AE3), CD31 and S100. Thus, the diagnosis of an intrapericardial solitary fibrous tumour was established. There has been no recurrence for 3 years based on the regular MRI follow-up. Intrapericardial SFTs, showing slow growth dynamics, can present with massive extent even in completely asymptomatic patients. MRI is exceedingly useful for characterizing intrapericardial masses, allowing precise surgical planning, and is reliable for long-term follow up.

  11. Porous silicon mass spectrometry as an alternative confirmatory assay for compliance testing of methadone.

    PubMed

    Guinan, Taryn M; Neldner, Declan; Stockham, Peter; Kobus, Hilton; Della Vedova, Christopher B; Voelcker, Nicolas H

    2017-05-01

    Porous silicon based surface-assisted laser desorption ionization mass spectrometry (pSi SALDI-MS) is an analytical technique well suited for high throughput analysis of low molecular weight compounds from biological samples. A potential application of this technology is the compliance monitoring of opioid addiction programmes, where methadone is used as a pharmacological treatment for drugs such as heroin. Here, we present the detection and quantification of methadone and 2-ethylidene-1,5-dimethyl-3,3-diphenylpyrrolidine (EDDP) from water and clinical samples (saliva, urine, and plasma) from opioid dependent participants using pSi SALDI-MS. A one-step solvent phase extraction using chloroform was developed for the detection of methadone from clinical samples for analysis by pSi SALDI-MS. Liquid chromatography-mass spectrometry (LC-MS) was used as a comparative technique for the quantification of methadone from clinical saliva and plasma samples. In all cases, we obtained a good correlation of pSi SALDI-MS and LC-MS results, suggesting that pSi SALDI-MS may be an alternative procedure for high-throughput screening and quantification for application in opioid compliance testing. Copyright © 2016 John Wiley & Sons, Ltd. Copyright © 2016 John Wiley & Sons, Ltd.

  12. WaferOptics® mass volume production and reliability

    NASA Astrophysics Data System (ADS)

    Wolterink, E.; Demeyer, K.

    2010-05-01

    The Anteryon WaferOptics® Technology platform contains imaging optics designs, materials, metrologies and combined with wafer level based Semicon & MEMS production methods. WaferOptics® first required complete new system engineering. This system closes the loop between application requirement specifications, Anteryon product specification, Monte Carlo Analysis, process windows, process controls and supply reject criteria. Regarding the Anteryon product Integrated Lens Stack (ILS), new design rules, test methods and control systems were assessed, implemented, validated and customer released for mass production. This includes novel reflowable materials, mastering process, replication, bonding, dicing, assembly, metrology, reliability programs and quality assurance systems. Many of Design of Experiments were performed to assess correlations between optical performance parameters and machine settings of all process steps. Lens metrologies such as FFL, BFL, and MTF were adapted for wafer level production and wafer mapping was introduced for yield management. Test methods for screening and validating suitable optical materials were designed. Critical failure modes such as delamination and popcorning were assessed and modeled with FEM. Anteryon successfully managed to integrate the different technologies starting from single prototypes to high yield mass volume production These parallel efforts resulted in a steep yield increase from 30% to over 90% in a 8 months period.

  13. Recommendations for a step‐wise comparative approach to the evaluation of new screening tests for colorectal cancer

    PubMed Central

    Senore, Carlo; Mandel, Jack S.; Allison, James E.; Atkin, Wendy S.; Benamouzig, Robert; Bossuyt, Patrick M. M.; Silva, Mahinda De; Guittet, Lydia; Halloran, Stephen P.; Haug, Ulrike; Hoff, Geir; Itzkowitz, Steven H.; Leja, Marcis; Levin, Bernard; Meijer, Gerrit A.; O'Morain, Colm A.; Parry, Susan; Rabeneck, Linda; Rozen, Paul; Saito, Hiroshi; Schoen, Robert E.; Seaman, Helen E.; Steele, Robert J. C.; Sung, Joseph J. Y.; Winawer, Sidney J.

    2016-01-01

    BACKGROUND New screening tests for colorectal cancer continue to emerge, but the evidence needed to justify their adoption in screening programs remains uncertain. METHODS A review of the literature and a consensus approach by experts was undertaken to provide practical guidance on how to compare new screening tests with proven screening tests. RESULTS Findings and recommendations from the review included the following: Adoption of a new screening test requires evidence of effectiveness relative to a proven comparator test. Clinical accuracy supported by programmatic population evaluation in the screening context on an intention‐to‐screen basis, including acceptability, is essential. Cancer‐specific mortality is not essential as an endpoint provided that the mortality benefit of the comparator has been demonstrated and that the biologic basis of detection is similar. Effectiveness of the guaiac‐based fecal occult blood test provides the minimum standard to be achieved by a new test. A 4‐phase evaluation is recommended. An initial retrospective evaluation in cancer cases and controls (Phase 1) is followed by a prospective evaluation of performance across the continuum of neoplastic lesions (Phase 2). Phase 3 follows the demonstration of adequate accuracy in these 2 prescreening phases and addresses programmatic outcomes at 1 screening round on an intention‐to‐screen basis. Phase 4 involves more comprehensive evaluation of ongoing screening over multiple rounds. Key information is provided from the following parameters: the test positivity rate in a screening population, the true‐positive and false‐positive rates, and the number needed to colonoscope to detect a target lesion. CONCLUSIONS New screening tests can be evaluated efficiently by this stepwise comparative approach. Cancer 2016;122:826–39. © 2016 The Authors. Cancer published by Wiley Periodicals, Inc. on behalf of American Cancer Society. PMID:26828588

  14. Recommendations for a step-wise comparative approach to the evaluation of new screening tests for colorectal cancer.

    PubMed

    Young, Graeme P; Senore, Carlo; Mandel, Jack S; Allison, James E; Atkin, Wendy S; Benamouzig, Robert; Bossuyt, Patrick M M; Silva, Mahinda De; Guittet, Lydia; Halloran, Stephen P; Haug, Ulrike; Hoff, Geir; Itzkowitz, Steven H; Leja, Marcis; Levin, Bernard; Meijer, Gerrit A; O'Morain, Colm A; Parry, Susan; Rabeneck, Linda; Rozen, Paul; Saito, Hiroshi; Schoen, Robert E; Seaman, Helen E; Steele, Robert J C; Sung, Joseph J Y; Winawer, Sidney J

    2016-03-15

    New screening tests for colorectal cancer continue to emerge, but the evidence needed to justify their adoption in screening programs remains uncertain. A review of the literature and a consensus approach by experts was undertaken to provide practical guidance on how to compare new screening tests with proven screening tests. Findings and recommendations from the review included the following: Adoption of a new screening test requires evidence of effectiveness relative to a proven comparator test. Clinical accuracy supported by programmatic population evaluation in the screening context on an intention-to-screen basis, including acceptability, is essential. Cancer-specific mortality is not essential as an endpoint provided that the mortality benefit of the comparator has been demonstrated and that the biologic basis of detection is similar. Effectiveness of the guaiac-based fecal occult blood test provides the minimum standard to be achieved by a new test. A 4-phase evaluation is recommended. An initial retrospective evaluation in cancer cases and controls (Phase 1) is followed by a prospective evaluation of performance across the continuum of neoplastic lesions (Phase 2). Phase 3 follows the demonstration of adequate accuracy in these 2 prescreening phases and addresses programmatic outcomes at 1 screening round on an intention-to-screen basis. Phase 4 involves more comprehensive evaluation of ongoing screening over multiple rounds. Key information is provided from the following parameters: the test positivity rate in a screening population, the true-positive and false-positive rates, and the number needed to colonoscope to detect a target lesion. New screening tests can be evaluated efficiently by this stepwise comparative approach. © 2016 The Authors. Cancer published by Wiley Periodicals, Inc. on behalf of American Cancer Society.

  15. Development and validation of a streamlined method designed to detect residues of 62 veterinary drugs in bovine kidney using ultra-high performance liquid chromatography--tandem mass spectrometry.

    PubMed

    Lehotay, Steven J; Lightfield, Alan R; Geis-Asteggiante, Lucía; Schneider, Marilyn J; Dutko, Terry; Ng, Chilton; Bluhm, Louis; Mastovska, Katerina

    2012-08-01

    In the USA, the US Department of Agriculture's Food Safety and Inspection Service (FSIS) conducts the National Residue Program designed to monitor veterinary drug and other chemical residues in beef and other slaughtered food animals. Currently, FSIS uses a 7-plate bioassay in the laboratory to screen for antimicrobial drugs in bovine kidneys from those animals tested positive by inspectors in the slaughter establishments. The microbial inhibition bioassay has several limitations in terms of monitoring scope, sensitivity, selectivity, and analysis time. Ultra-high performance liquid chromatography - tandem mass spectrometry (UHPLC-MS/MS) has many advantages over the bioassay for this application, and this study was designed to develop, evaluate, and validate a fast UHPLC-MS/MS method for antibiotics and other high-priority veterinary drugs in bovine kidney. Five existing multi-class, multi-residue methods from the literature were tested and compared, and each performed similarly. Experiments with incurred samples demonstrated that a 5-min shake of 2 g homogenized kidney with 10 ml of 4/1 (v/v) acetonitrile/water followed by simultaneous clean-up of the initial extract with 0.5 g C18 and 10 ml hexane gave a fast, simple, and effective sample preparation method for the <10 min UHPLC-MS/MS analysis. An extensive 5-day validation process demonstrated that the final method could be used to acceptably screen for 54 of the 62 drugs tested, and 50 of those met qualitative MS identification criteria. Quantification was not needed in the application, but the method gave ≥ 70% recoveries and ≤ 25% reproducibilities for 30 of the drugs. Published 2012. This article is a U.S. Government work and is in the public domain of the USA.

  16. Body mass index predicts selected physical fitness attributes but is not associated with performance on military relevant tasks in U.S. Army Soldiers.

    PubMed

    Pierce, Joseph R; DeGroot, David W; Grier, Tyson L; Hauret, Keith G; Nindl, Bradley C; East, Whitfield B; McGurk, Michael S; Jones, Bruce H

    2017-11-01

    Army body composition standards are based upon validated criteria; however, certain field-expedient methodologies (e.g., weight-for-height, body mass index [BMI]) may disqualify individuals from service who may otherwise excel on physical performance and military-relevant tasks. The purpose was to assess soldier physical performance and military-specific task/fitness performance stratified by BMI. Cross-sectional observational study. Male (n=275) and female (n=46) soldiers performed a wide-array of physical fitness tests and military-specific tasks, including the Army physical fitness test (APFT). Within-sex performance data were analyzed by BMI tertile stratification or by Army Body Composition Program (ABCP) weight-for-height (calculated BMI) screening standards using ANOVA/Tukey post-hoc or independent t-tests, respectively. BMI stratification (higher vs. lower BMI) was associated with significant improvements in muscular strength and power, but also with decrements in speed/agility in male and female soldiers. Within the military specific tasks, a higher BMI was associated with an increased APFT 2-Mile Run time; however, performance on a 1600-m Loaded March or a Warrior Task and Battle Drill obstacle course was not related to BMI in either sex. Male and Female soldiers who did not meet ABCP screening standards demonstrated a slower 2-Mile Run time; however, not meeting the ABCP BMI standard only affected a minimal number (∼6%) of soldiers' ability to pass the APFT. Military body composition standards require a careful balance between physical performance, health, and military readiness. Allowances should be considered where tradeoffs exist between body composition classifications and performance on physical tasks with high military relevance. Published by Elsevier Ltd.

  17. Metabolites as novel biomarkers for childhood obesity-related traits in Mexican-American children.

    PubMed

    Farook, V S; Reddivari, L; Chittoor, G; Puppala, S; Arya, R; Fowler, S P; Hunt, K J; Curran, J E; Comuzzie, A G; Lehman, D M; Jenkinson, C P; Lynch, J L; DeFronzo, R A; Blangero, J; Hale, D E; Duggirala, R; Vanamala, J

    2015-08-01

    Although newer approaches have identified several metabolites associated with obesity, there is paucity of such information in paediatric populations, especially among Mexican-Americans (MAs) who are at high risk of obesity. Therefore, we performed a global serum metabolite screening in MA children to identify biomarkers of childhood obesity. We selected 15 normal-weight, 13 overweight and 14 obese MA children (6-17 years) and performed global serum metabolite screening using ultra-performance liquid chromatography/quadruple orthogonal acceleration time of flight tandem micro mass spectrometer. Metabolite values were analysed to assess mean differences among groups using one-way analysis of variance, to test for linear trend across groups and to examine Pearson's correlations between them and seven cardiometabolic traits (CMTs): body mass index, waist circumference, systolic blood pressure, diastolic blood pressure, homeostasis model of assessment-insulin resistance, triglycerides and high-density lipoprotein cholesterol. We identified 14 metabolites exhibiting differences between groups as well as linear trend across groups with nominal statistical significance. After adjustment for multiple testing, mean differences and linear trends across groups remained significant (P < 5.9 × 10(-5) ) for L-thyronine, bradykinin and naringenin. Of the examined metabolite-CMT trait pairs, all metabolites except for 2-methylbutyroylcarnitine were nominally associated with two or more CMTs, some exhibiting significance even after accounting for multiple testing (P < 3.6 × 10(-3) ). To our knowledge, this study - albeit pilot in nature - is the first study to identify these metabolites as novel biomarkers of childhood obesity and its correlates. These findings signify the need for future systematic investigations of metabolic pathways underlying childhood obesity. © 2014 World Obesity.

  18. Systematic screening and characterization of flavonoid glycosides in Carthamus tinctorius L. by liquid chromatography/UV diode-array detection/electrospray ionization tandem mass spectrometry.

    PubMed

    Jin, Yu; Xiao, Yuan-sheng; Zhang, Fei-fang; Xue, Xing-ya; Xu, Qing; Liang, Xin-miao

    2008-02-13

    The traditional Chinese medicine (TCM) is a complex system, which always consists of numerous compounds with significant difference in the content and physical and chemical properties. In this paper, a screening method based on target molecular weights was developed to characterize the flavonoid glycosides in the flower of Carthamus tinctorius L. The screening tables of aglycone and glycan were designed, respectively, in order to select and combine freely. The multiple reaction monitoring (MRM) scan mode with higher sensitivity and selectivity was adopted in the screening, which benefit the characterization for the minor components. Seventy-seven flavonoid glycosides were screened out finally, and their structures were characterized by tandem mass spectrometric method in both positive and negative ion modes. The glycosylation mode, aglycone, sequence and/or the interglycosidic linkages of the glycan portion and glycosylation position were elucidated by the fragmentation rule in the MS. Numerous compounds screened out with this method showed the structure variety in secondary plant metabolites, and the purposeful screening systemically and subsequent structure characterization offered more information about the chemical constitutions of TCM.

  19. Is School-Based Height and Weight Screening of Elementary Students Private and Reliable?

    ERIC Educational Resources Information Center

    Stoddard, Sarah A.; Kubik, Martha Y.; Skay, Carol

    2008-01-01

    The Institute of Medicine recommends school-based body mass index (BMI) screening as an obesity prevention strategy. While school nurses have provided height/weight screening for years, little has been published describing measurement reliability or process. This study evaluated the reliability of height/weight measures collected by school nurses…

  20. Sickle Cell Screening: Medical, Legal, Ethical, Psychological and Social Problems; A Sickle Cell Crisis.

    ERIC Educational Resources Information Center

    Bowman, James E.

    In recent years, sickle cell screening programs have been initiated by community groups, health centers, hospitals, medical schools, health departments, school systems, city and State governments, various branches of the Federal Government, fraternal and social clubs, and other organizations. Problems have resulted from mass sickle cell screening,…

  1. 10 CFR 960.3-2-1 - Site screening for potentially acceptable sites.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... POTENTIAL SITES FOR A NUCLEAR WASTE REPOSITORY Implementation Guidelines § 960.3-2-1 Site screening for... first repository, the process shall begin with site-screening activities that consider large land masses... repositories, the Secretary shall first identify the State within which the site is located in a decision-basis...

  2. Y-balance test: a reliability study involving multiple raters.

    PubMed

    Shaffer, Scott W; Teyhen, Deydre S; Lorenson, Chelsea L; Warren, Rick L; Koreerat, Christina M; Straseske, Crystal A; Childs, John D

    2013-11-01

    The Y-balance test (YBT) is one of the few field expedient tests that have shown predictive validity for injury risk in an athletic population. However, analysis of the YBT in a heterogeneous population of active adults (e.g., military, specific occupations) involving multiple raters with limited experience in a mass screening setting is lacking. The primary purpose of this study was to determine interrater test-retest reliability of the YBT in a military setting using multiple raters. Sixty-four service members (53 males, 11 females) actively conducting military training volunteered to participate. Interrater test-retest reliability of the maximal reach had intraclass correlation coefficients (2,1) of 0.80 to 0.85 with a standard error of measurement ranging from 3.1 to 4.2 cm for the 3 reach directions (anterior, posteromedial, and posterolateral). Interrater test-retest reliability of the average reach of 3 trails had an intraclass correlation coefficients (2,3) range of 0.85 to 0.93 with an associated standard error of measurement ranging from 2.0 to 3.5cm. The YBT showed good interrater test-retest reliability with an acceptable level of measurement error among multiple raters screening active duty service members. In addition, 31.3% (n = 20 of 64) of participants exhibited an anterior reach asymmetry of >4cm, suggesting impaired balance symmetry and potentially increased risk for injury. Reprint & Copyright © 2013 Association of Military Surgeons of the U.S.

  3. Racial and Ethnic Disparities in Diabetes Screening Between Asian Americans and Other Adults: BRFSS 2012-2014.

    PubMed

    Tung, Elizabeth L; Baig, Arshiya A; Huang, Elbert S; Laiteerapong, Neda; Chua, Kao-Ping

    2017-04-01

    Although Asian Americans are at high risk for type 2 diabetes, it is not known whether they are appropriately screened for this disease. To assess racial and ethnic disparities in diabetes screening between Asian Americans and other adults. Analysis of pooled cross-sectional data from 45 U.S. states and territories using the 2012-2014 Behavioral Risk Factor Surveillance System. We calculated the weighted proportions of adults in each racial and ethnic group who received recommended diabetes screening. To assess for racial and ethnic disparities, we used multivariable logistic regression to model receipt of recommended diabetes screening as a function of race and ethnicity, adjusting for demographics, healthcare access, survey year, and state. A total of 526,000 adults who were eligible to receive diabetes screening according to American Diabetes Association guidelines from 2012 to 2014 (age ≥ 45 years or age < 45 years with a body mass index [BMI] ≥ 25 kg/m 2 ). Self-reported receipt of diabetes screening (defined as a test for high blood sugar or diabetes within the past 3 years) and self-reported race/ethnicity (non-Hispanic white, non-Hispanic Asian, non-Hispanic Pacific Islander, non-Hispanic American Indian or Alaskan Native, non-Hispanic black, Hispanic or Latino, and non-Hispanic multiracial or other). Asian Americans were the least likely racial and ethnic group to receive recommended diabetes screening. Overall, Asian Americans had 34% lower adjusted odds of receiving recommended diabetes screening compared to non-Hispanic whites (95 % CI: 0.60, 0.73). In subgroup analyses by age and weight status, disparities were widest among obese Asian Americans ≥ 45 years (AOR = 0.56; 95 % CI: 0.39, 0.81). Disparities persisted among Asian Americans who completed other types of preventive cancer screening. Despite their high risk of diabetes, Asian Americans were the least likely racial and ethnic group to receive recommended diabetes screening.

  4. Screening of polar components of petroleum products by electrospray ionization mass spectrometry

    USGS Publications Warehouse

    Rostad, Colleen E.

    2005-01-01

    The polar components of fuels may enable differentiation between fuel types or commercial fuel sources. Screening for these components in the hydrocarbon product is difficult due to their very low concentrations in such a complex matrix. Various commercial fuels from several sources were analyzed by flow injection analysis/electrospray ionization/mass spectrometry without extensive sample preparation, separation, or chromatography. This technique enabled screening for unique polar components at very low concentrations in commercial hydrocarbon products. This analysis was then applied to hydrocarbon samples collected from the subsurface with a different extent of biodegradation or weathering. Although the alkane and isoprenoid portion had begun to biodegrade or weather, the polar components had changed little over time. Because these polar compounds are unique in different fuels, this screening technique can provide source information on hydrocarbons released into the environment.

  5. An integrated high resolution mass spectrometric data acquisition method for rapid screening of saponins in Panax notoginseng (Sanqi).

    PubMed

    Lai, Chang-Jiang-Sheng; Tan, Ting; Zeng, Su-Ling; Qi, Lian-Wen; Liu, Xin-Guang; Dong, Xin; Li, Ping; Liu, E-Hu

    2015-05-10

    The aim of this study was to develop a convenient method without pretreatments for nontarget discovery of interested compounds. The segment and exposure strategy, coupled with two mass spectrometer data acquisition methods was firstly proposed for screening the saponins in extract of Panax notoginseng (Sanqi) via high-performance liquid chromatography tandem quadrupole time-of-flight mass spectrometry (HPLC-QTOF/MS). By gradually removing certain major or moderate interference compounds, the developed segment and exposure strategy could significantly improve the detection efficiency for trace compounds. Moreover, the newly developed five-point screening approach based on a modified mass defect filter strategy and the visual isotopic ion technique was verified to be efficient and reliable in picking out the interested precursor ions. In total, 234 ginsenosides including 67 potential new ones were characterized or tentatively identified from the extract of Sanqi. Particularly, some unusual compounds containing the branched glycosyl group or new substituted acyl groups were firstly reported. The proposed integrated strategy held a strong promise for analyses of the complex mixtures. Copyright © 2015 Elsevier B.V. All rights reserved.

  6. The detection of THC, CBD and CBN in the oral fluid of Sativex® patients using two on-site screening tests and LC-MS/MS.

    PubMed

    Molnar, Anna; Fu, Shanlin; Lewis, John; Allsop, David J; Copeland, Jan

    2014-05-01

    Sativex(®) is an oromucosal spray used to treat spasticity in multiple sclerosis sufferers in some European countries, the United Kingdom, Canada and New Zealand. The drug has also recently been registered by the Therapeutic Goods Administration (TGA) in Australia for treatment of multiple sclerosis. Sativex(®) contains high concentrations of Δ(9)-tetrahydrocannabinol (THC) and cannabidiol (CBD), with the former being the subject of random roadside drug tests across Australia to detect cannabis use. This pilot study aims to determine whether or not patients taking Sativex(®) will test positive to THC using these roadside screening tests. Detectable levels of THC, CBD and cannabinol (CBN) in their oral fluid were also confirmed by liquid chromatography-tandem mass spectrometry (LC-MS/MS). The study was a double-blind, placebo controlled design. Oral fluid was tested prior to and immediately after dosing with either Sativex(®) or placebo at intervals up to 2h after the dose. Two Sativex(®) doses were studied. The low dose contained 5.4mg THC, the high dose 21.6mg THC. Results indicate that the primary screening test used in Australian roadside drug testing, the DrugWipe(®) II Twin, often gave a false negative response for THC, even with high concentrations present. However, secondary screening test, Cozart(®) DDS (used by police after a DrugWipe test gives a positive result), gave true positive results in all cases where patients were being treated with Sativex(®). Confirmatory testing showed high concentrations of THC and CBD (>5356ng/mL THC and >3826ng/mL CBD) in the oral fluid shortly after dosing and also elevated concentrations of CBN. Levels dropped quickly but remained at detectable concentrations (>67.6ng/mL) two hours after drug administration. The average concentration ratio of THC/CBD across all positive samples was 1.10 (%RSD 19.9) reflecting the composition of the Sativex(®) spray. In conclusion, Sativex(®) users may test positive for THC by roadside drug testing within 2-3h of use. Confirmatory analysis can identify Sativex(®) treatment through use of THC/CBD ratios, however, these ratios would unlikely be sufficient to differentiate non-medicinal cannabis use from Sativex(®) use if both are taken concurrently. Copyright © 2014 Elsevier Ireland Ltd. All rights reserved.

  7. The current revolution in newborn screening: new technology, old controversies.

    PubMed

    Tarini, Beth A

    2007-08-01

    Newborn screening has provided a model of a successful public health screening program for the past 40 years. However, the history of newborn screening is not without controversy. Many of these controversies have been rekindled with the introduction of tandem mass spectrometry, a technology that has greatly increased our ability to detect potential disease in asymptomatic newborns. This review highlights the challenges raised by this and future technological advances as we strive to maintain the success of newborn screening in the 21st century.

  8. Radiologists' preferences for digital mammographic display. The International Digital Mammography Development Group.

    PubMed

    Pisano, E D; Cole, E B; Major, S; Zong, S; Hemminger, B M; Muller, K E; Johnston, R E; Walsh, R; Conant, E; Fajardo, L L; Feig, S A; Nishikawa, R M; Yaffe, M J; Williams, M B; Aylward, S R

    2000-09-01

    To determine the preferences of radiologists among eight different image processing algorithms applied to digital mammograms obtained for screening and diagnostic imaging tasks. Twenty-eight images representing histologically proved masses or calcifications were obtained by using three clinically available digital mammographic units. Images were processed and printed on film by using manual intensity windowing, histogram-based intensity windowing, mixture model intensity windowing, peripheral equalization, multiscale image contrast amplification (MUSICA), contrast-limited adaptive histogram equalization, Trex processing, and unsharp masking. Twelve radiologists compared the processed digital images with screen-film mammograms obtained in the same patient for breast cancer screening and breast lesion diagnosis. For the screening task, screen-film mammograms were preferred to all digital presentations, but the acceptability of images processed with Trex and MUSICA algorithms were not significantly different. All printed digital images were preferred to screen-film radiographs in the diagnosis of masses; mammograms processed with unsharp masking were significantly preferred. For the diagnosis of calcifications, no processed digital mammogram was preferred to screen-film mammograms. When digital mammograms were preferred to screen-film mammograms, radiologists selected different digital processing algorithms for each of three mammographic reading tasks and for different lesion types. Soft-copy display will eventually allow radiologists to select among these options more easily.

  9. Recruitment methods employed in the prostate, lung, colorectal, and ovarian cancer screening trial

    PubMed Central

    Gren, Lisa; Broski, Karen; Childs, Jeffery; Cordes, Jill; Engelhard, Deborah; Gahagan, Betsy; Gamito, Eduard; Gardner, Vivien; Geisser, Mindy; Higgins, Darlene; Jenkins, Victoria; Lamerato, Lois; Lappe, Karen; Lowery, Heidi; McGuire, Colleen; Miedzinski, Mollie; Ogden, Sheryl; Tenorio, Sally; Watt, Gavin; Wohlers, Bonita; Marcus, Pamela

    2015-01-01

    Background The Prostate, Lung, Colorectal and Ovarian Cancer Screening Trial (PLCO) is a US National Cancer Institute (NCI)-funded randomized controlled trial designed to evaluate whether certain screening tests reduce mortality from prostate, lung, colorectal, and ovarian cancer. To obtain adequate statistical power, it was necessary to enroll over 150,000 healthy volunteers. Recruitment began in 1993 and ended in 2001. Purpose Our goal is to evaluate the success of recruitment methods employed by the 10 PLCO screening centers. We also provide estimates of recruitment yield and cost for our most successful strategy, direct mail. Methods Each screening center selected its own methods of recruitment. Methods changed throughout the recruitment period as needed. For this manuscript, representatives from each screening center provided information on methods utilized and their success. Results In the United States between 1993 and 2001, ten screening centers enrolled 154,934 study participants. Based on participant self-report, an estimated 95% of individuals were recruited by direct mail. Overall, enrollment yield for direct mail was 1.0%. Individual center enrollment yield ranged from 0.7% to 3.8%. Cost per enrolled participant was $9.64–35.38 for direct mail, excluding personnel costs. Limitations Numeric data on recruitment processes were not kept consistently at individual screening centers. Numeric data in this manuscript are based on the experiences of 5 of the 10 centers. Conclusions Direct mail, using rosters of names and addresses from profit and not-for-profit (including government) organizations, was the most successful and most often used recruitment method. Other recruitment strategies, such as community outreach and use of mass media, can be an important adjunct to direct mail in recruiting minority populations. PMID:19254935

  10. 42 CFR 410.17 - Cardiovascular disease screening tests.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 42 Public Health 2 2011-10-01 2011-10-01 false Cardiovascular disease screening tests. 410.17... § 410.17 Cardiovascular disease screening tests. (a) Definition. For purposes of this subpart, the... Part B covers cardiovascular disease screening tests when ordered by the physician who is treating the...

  11. 42 CFR 410.17 - Cardiovascular disease screening tests.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... 42 Public Health 2 2012-10-01 2012-10-01 false Cardiovascular disease screening tests. 410.17... § 410.17 Cardiovascular disease screening tests. (a) Definition. For purposes of this subpart, the... Part B covers cardiovascular disease screening tests when ordered by the physician who is treating the...

  12. 42 CFR 410.17 - Cardiovascular disease screening tests.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... 42 Public Health 2 2013-10-01 2013-10-01 false Cardiovascular disease screening tests. 410.17... § 410.17 Cardiovascular disease screening tests. (a) Definition. For purposes of this subpart, the... Part B covers cardiovascular disease screening tests when ordered by the physician who is treating the...

  13. 42 CFR 410.17 - Cardiovascular disease screening tests.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... 42 Public Health 2 2014-10-01 2014-10-01 false Cardiovascular disease screening tests. 410.17... § 410.17 Cardiovascular disease screening tests. (a) Definition. For purposes of this subpart, the... Part B covers cardiovascular disease screening tests when ordered by the physician who is treating the...

  14. 42 CFR 410.17 - Cardiovascular disease screening tests.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 42 Public Health 2 2010-10-01 2010-10-01 false Cardiovascular disease screening tests. 410.17... § 410.17 Cardiovascular disease screening tests. (a) Definition. For purposes of this subpart, the... Part B covers cardiovascular disease screening tests when ordered by the physician who is treating the...

  15. Uptake of prenatal diagnostic testing and the effectiveness of prenatal screening for Down syndrome.

    PubMed

    Jaques, Alice M; Collins, Veronica R; Muggli, Evelyne E; Amor, David J; Francis, Ivan; Sheffield, Leslie J; Halliday, Jane L

    2010-06-01

    To map prenatal screening and diagnostic testing pathways in Victorian pregnant women during 2003 to 2004; measure the impact of prenatal diagnostic testing uptake on the effectiveness of prenatal screening for Down syndrome; and assess factors influencing uptake of diagnostic testing following screening. State-wide data collections of prenatal screening and diagnostic tests were linked to all Victorian births and pregnancy terminations for birth defects. Overall, 52% of women had a prenatal test (65 692/126 305); screening (44.9%), diagnostic testing (3.9%), or both (3.2%). Uptake of diagnostic testing was 71.4% (2390/3349) after an increased risk screen result, and 2.5% (1381/54 286) after a low risk result. Variation in uptake of diagnostic testing reduced the effectiveness of the screening program by 11.2%: from 87.4% (sensitivity - 125/143) to 76.2% (prenatal diagnoses of Down syndrome - 109/143). In both the increased and low risk groups, uptake was influenced by absolute numerical risk, as well as by the change in numerical risk from a priori risk. This comprehensive follow-up demonstrates clearly that numerical risk is being used to aid in decision making about confirmatory diagnostic testing. Collectively, these fundamental individual decisions will impact on the overall effectiveness of screening programmes for Down syndrome.

  16. An RF Sensor for Gauging Screen-Channel Liquid Acquisition Devices for Cryogenic Propellants

    NASA Technical Reports Server (NTRS)

    Zimmerli, Gregory A.; Metzger, Scott; Asipauskas, Marius

    2014-01-01

    A key requirement of a low-gravity screen-channel liquid acquisition device (LAD) is the need to retain 100% liquid in the channel in response to propellant outflow and spacecraft maneuvers. The point at which a screen-channel LAD ingests vapor is known as breakdown, and can be measured several different ways such as: visual observation of bubbles in the LAD channel outflow; a sudden change in pressure drop between the propellant tank and LAD sump outlet; or, an indication by wet-dry sensors placed in the LAD channel or outflow stream. Here we describe a new type of sensor for gauging a screen-channel LAD, the Radio Frequency Mass Gauge (RFMG). The RFMG measures the natural electromagnetic modes of the screen-channel LAD, which is very similar to an RF waveguide, to determine the amount of propellant in the channel. By monitoring several of the RF modes, we show that the RFMG acts as a global sensor of the LAD channel propellant fill level, and enables detection of LAD breakdown even in the absence of outflow. This paper presents the theory behind the RFMG-LAD sensor, measurements and simulations of the RF modes of a LAD channel, and RFMG detection of LAD breakdown in a channel using a simulant fluid during inverted outflow and long-term stability tests.

  17. Optimization of printing techniques for electrochemical biosensors

    NASA Astrophysics Data System (ADS)

    Zainuddin, Ahmad Anwar; Mansor, Ahmad Fairuzabadi Mohd; Rahim, Rosminazuin Ab; Nordin, Anis Nurashikin

    2017-03-01

    Electrochemical biosensors show great promise for point-of-care applications due to their low cost, portability and compatibility with microfluidics. The miniature size of these sensors provides advantages in terms of sensitivity, specificity and allows them to be mass produced in arrays. The most reliable fabrication technique for these sensors is lithography followed by metal deposition using sputtering or chemical vapor deposition techniques. This technique which is usually done in the cleanroom requires expensive masking followed by deposition. Recently, cheaper printing techniques such as screen-printing and ink-jet printing have become popular due to its low cost, ease of fabrication and mask-less method. In this paper, two different printing techniques namely inkjet and screen printing are demonstrated for an electrochemical biosensor. For ink-jet printing technique, optimization of key printing parameters, such as pulse voltages, drop spacing and waveform setting, in-house temperature and cure annealing for obtaining the high quality droplets, are discussed. These factors are compared with screen-printing parameters such as mesh size, emulsion thickness, minimum spacing of lines and curing times. The reliability and reproducibility of the sensors are evaluated using scotch tape test, resistivity and profile-meter measurements. It was found that inkjet printing is superior because it is mask-less, has minimum resolution of 100 µm compared to 200 µm for screen printing and higher reproducibility rate of 90% compared to 78% for screen printing.

  18. First case of Hb Fontainebleau with sickle haemoglobin and other non-deletional α gene variants identified in neonates during newborn screening for sickle cell disorders.

    PubMed

    Upadhye, Dipti S; Jain, Dipty; Nair, Sona B; Nadkarni, Anita H; Ghosh, Kanjaksha; Colah, Roshan B

    2012-07-01

    To evaluate the significance of non-deletional α gene variants identified in neonates during newborn screening for sickle cell disorders. 1534 newborn babies were screened in the last 2 years for sickle cell disease using a targeted screening approach. Investigations included a complete blood count, high performance liquid chromatography analysis, cellulose acetate electrophoresis (pH 8.9), heat stability test, restriction digestion and Amplified Refractory Mutation System for confirmation of sickle haemoglobin (Hb S), α genotyping by multiplex PCR and DNA sequencing. Three non-deletional α gene variants, Hb Fontainebleau, Hb O Indonesia and Hb Koya Dora, were identified in heterozygous condition in newborns. This is the first report of Hb Fontainebleau in association with Hb S. The baby had anaemia at birth (Hb 11.4 g/dl) with no cyanosis, icterus or need for transfusion. She had occipital encephalocoele and was operated on day 24 to remove the mass. The baby diagnosed with Hb O Indonesia in combination with Hb S also had a low haemoglobin level of 12.7 g/dl. Newborn screening for sickle cell disorders also enabled us to identify three α globin chain variants. Two babies who inherited Hb Fontainebleau and Hb O Indonesia along with Hb S had reduced Hb levels at birth and need to be followed up.

  19. Comparison of Lateral Flow Assay, Kidney Inhibition Swab, and Liquid Chromatography-Tandem Mass Spectrometry for the Detection of Penicillin G Residues in Sow Urine.

    PubMed

    Shelver, Weilin L; Chakrabarty, Shubhashis; Smith, David J

    2017-03-01

    Sows (n = 126) were administered penicillin G; urine, collected at slaughter, was screened by kidney inhibition swab (KIS; 4 h testing time) and then stored at -80 °C (∼1200 days) until analysis by lateral flow assay (LF, ∼5 min testing time) and tandem quadrupole LC-MS/MS (TQ) analysis. The stability of penicillin in urine during storage was verified using TQ analyses. Quantitative results were well-correlated (R 2 = 0.98) with only a ∼10% decrease in penicillin concentration during the 3-year storage period. KIS retesting of stored samples returned results consistent with the original analyses. Lateral flow assay results were highly correlated with the KIS and TQ results. A KIS positive sample, which was not confirmed by TQ or LF, was assayed by Triple-TOF LC-MS to determine the cause of the apparent false positive. This study suggests LF can be used to quickly and efficiently screen for penicillin G residues before slaughter.

  20. HE4 as a biomarker for ovarian and endometrial cancer management

    PubMed Central

    Li, Jinping; Dowdy, Sean; Tipton, Tracy; Podratz, Karl; Lu, Wei-Guo; Xie, Xing; Jiang, Shi-Wen

    2012-01-01

    Ovarian and endometrial cancer will be diagnosed in over 63,000 women in 2009, resulting in 22,000 deaths in the USA. Histologic screening, such as pap smears for detection of cervical cancer, is not feasible for these diseases given difficulty with access to the tissue. Thus, a serum-screening test using a biomarker or panel of biomarkers would be useful to aid in cancer diagnosis, detection of recurrence and as a means to monitor response to therapy. In this review, we focus on the human epididymis protein (HE)4 gene, which appears to have potential as a biomarker for both of these diseases. The structure and methods of detection of HE4 are discussed. Preliminary data show that HE4 may have more potential than cancer antigen 125 in discriminating benign from cancerous ovarian masses, and has the strongest correlation with endometrial cancer of all markers tested to date. Utilizing risk stratification, a panel of biomarkers including HE4 may ultimately be useful for detecting ovarian and endometrial cancer at an early stage in patients at high risk. PMID:19732003

  1. Newborn screening by tandem mass spectrometry for glutaric aciduria type 1: a cost-effectiveness analysis.

    PubMed

    Pfeil, Johannes; Listl, Stefan; Hoffmann, Georg F; Kölker, Stefan; Lindner, Martin; Burgard, Peter

    2013-10-17

    Glutaric aciduria type I (GA-I) is a rare metabolic disorder caused by inherited deficiency of glutaryl-CoA dehydrogenase. Despite high prognostic relevance of early diagnosis and start of metabolic treatment as well as an additional cost saving potential later in life, only a limited number of countries recommend newborn screening for GA-I. So far only limited data is available enabling health care decision makers to evaluate whether investing into GA-I screening represents value for money. The aim of our study was therefore to assess the cost-effectiveness of newborn screening for GA-I by tandem mass spectrometry (MS/MS) compared to a scenario where GA-I is not included in the MS/MS screening panel. We assessed the cost-effectiveness of newborn screening for GA-I against the alternative of not including GA-I in MS/MS screening. A Markov model was developed simulating the clinical course of screened and unscreened newborns within different time horizons of 20 and 70 years. Monte Carlo simulation based probabilistic sensitivity analysis was used to determine the probability of GA-I screening representing a cost-effective therapeutic strategy. Within a 20 year time horizon, GA-I screening averts approximately 3.7 DALYs (95% CI 2.9 - 4.5) and about one life year is gained (95% CI 0.7 - 1.4) per 100,000 neonates screened initially . Moreover, the screening programme saves a total of around 30,682 Euro (95% CI 14,343 to 49,176 Euro) per 100,000 screened neonates over a 20 year time horizon. Within the limitations of the present study, extending pre-existing MS/MS newborn screening programmes by GA-I represents a highly cost-effective diagnostic strategy when assessed under conditions comparable to the German health care system.

  2. Early Adoption of a Multitarget Stool DNA Test for Colorectal Cancer Screening.

    PubMed

    Finney Rutten, Lila J; Jacobson, Robert M; Wilson, Patrick M; Jacobson, Debra J; Fan, Chun; Kisiel, John B; Sweetser, Seth; Tulledge-Scheitel, Sidna M; St Sauver, Jennifer L

    2017-05-01

    To characterize early adoption of a novel multitarget stool DNA (MT-sDNA) screening test for colorectal cancer (CRC) screening and to test the hypothesis that adoption differs by demographic characteristics and prior CRC screening behavior and proceeds predictably over time. We used the Rochester Epidemiology Project research infrastructure to assess the use of the MT-sDNA screening test in adults aged 50 to 75 years living in Olmsted County, Minnesota, in 2014 and identified 27,147 individuals eligible or due for screening colonoscopy from November 1, 2014, through November 30, 2015. We used electronic Current Procedure Terminology and Health Care Common Procedure codes to evaluate early adoption of the MT-sDNA screening test in this population and to test whether early adoption varies by age, sex, race, and prior CRC screening behavior. Overall, 2193 (8.1%) and 974 (3.6%) individuals were screened by colonoscopy and MT-sDNA, respectively. Age, sex, race, and prior CRC screening behavior were significantly and independently associated with MT-sDNA screening use compared with colonoscopy use after adjustment for all other variables (P<.05 for all). The rates of adoption of MT-sDNA screening increased over time and were highest in those aged 50 to 54 years, women, whites, and those who had a history of screening. The use of the MT-sDNA screening test varied predictably by insurance coverage. The rates of colonoscopy decreased over time, whereas overall CRC screening rates remained steady. The results of the present study are generally consistent with predictions derived from prior research and the diffusion of innovation framework, pointing to increasing use of the new screening test over time and early adoption by younger patients, women, whites, and those with prior CRC screening. Copyright © 2017 Mayo Foundation for Medical Education and Research. Published by Elsevier Inc. All rights reserved.

  3. Neuroblastoma Screening

    MedlinePlus

    ... including physical and emotional problems. False-negative test results can occur. Screening test results may appear to ... even if there are symptoms. False-positive test results can occur. Screening test results may appear to ...

  4. Advantages and Challenges of Dried Blood Spot Analysis by Mass Spectrometry Across the Total Testing Process

    PubMed Central

    Zakaria, Rosita; Allen, Katrina J.; Koplin, Jennifer J.; Roche, Peter

    2016-01-01

    Introduction Through the introduction of advanced analytical techniques and improved throughput, the scope of dried blood spot testing utilising mass spectrometric methods, has broadly expanded. Clinicians and researchers have become very enthusiastic about the potential applications of dried blood spot based mass spectrometric applications. Analysts on the other hand face challenges of sensitivity, reproducibility and overall accuracy of dried blood spot quantification. In this review, we aim to bring together these two facets to discuss the advantages and current challenges of non-newborn screening applications of dried blood spot quantification by mass spectrometry. Methods To address these aims we performed a key word search of the PubMed and MEDLINE online databases in conjunction with individual manual searches to gather information. Keywords for the initial search included; “blood spot” and “mass spectrometry”; while excluding “newborn”; and “neonate”. In addition, databases were restricted to English language and human specific. There was no time period limit applied. Results As a result of these selection criteria, 194 references were identified for review. For presentation, this information is divided into: 1) clinical applications; and 2) analytical considerations across the total testing process; being pre-analytical, analytical and post-analytical considerations. Conclusions DBS analysis using MS applications is now broadly applied, with drug monitoring for both therapeutic and toxicological analysis being the most extensively reported. Several parameters can affect the accuracy of DBS measurement and further bridge experiments are required to develop adjustment rules for comparability between dried blood spot measures and the equivalent serum/plasma values. Likewise, the establishment of independent reference intervals for dried blood spot sample matrix is required. PMID:28149263

  5. Optimization of LC-Orbitrap-HRMS acquisition and MZmine 2 data processing for nontarget screening of environmental samples using design of experiments.

    PubMed

    Hu, Meng; Krauss, Martin; Brack, Werner; Schulze, Tobias

    2016-11-01

    Liquid chromatography-high resolution mass spectrometry (LC-HRMS) is a well-established technique for nontarget screening of contaminants in complex environmental samples. Automatic peak detection is essential, but its performance has only rarely been assessed and optimized so far. With the aim to fill this gap, we used pristine water extracts spiked with 78 contaminants as a test case to evaluate and optimize chromatogram and spectral data processing. To assess whether data acquisition strategies have a significant impact on peak detection, three values of MS cycle time (CT) of an LTQ Orbitrap instrument were tested. Furthermore, the key parameter settings of the data processing software MZmine 2 were optimized to detect the maximum number of target peaks from the samples by the design of experiments (DoE) approach and compared to a manual evaluation. The results indicate that short CT significantly improves the quality of automatic peak detection, which means that full scan acquisition without additional MS 2 experiments is suggested for nontarget screening. MZmine 2 detected 75-100 % of the peaks compared to manual peak detection at an intensity level of 10 5 in a validation dataset on both spiked and real water samples under optimal parameter settings. Finally, we provide an optimization workflow of MZmine 2 for LC-HRMS data processing that is applicable for environmental samples for nontarget screening. The results also show that the DoE approach is useful and effort-saving for optimizing data processing parameters. Graphical Abstract ᅟ.

  6. Activity screening of carrier domains within nonribosomal peptide synthetases using complex substrate mixtures and large molecule mass spectrometry.

    PubMed

    Dorrestein, Pieter C; Blackhall, Jonathan; Straight, Paul D; Fischbach, Michael A; Garneau-Tsodikova, Sylvie; Edwards, Daniel J; McLaughlin, Shaun; Lin, Myat; Gerwick, William H; Kolter, Roberto; Walsh, Christopher T; Kelleher, Neil L

    2006-02-14

    For screening a pool of potential substrates that load carrier domains found in nonribosomal peptide synthetases, large molecule mass spectrometry is shown to be a new, unbiased assay. Combining the high resolving power of Fourier transform mass spectrometry with the ability of adenylation domains to select their own substrates, the mass change that takes place upon formation of a covalent intermediate thus identifies the substrate. This assay has an advantage over traditional radiochemical assays in that many substrates, the substrate pool, can be screened simultaneously. Using proteins on the nikkomycin, clorobiocin, coumermycin A1, yersiniabactin, pyochelin, and enterobactin biosynthetic pathways as proof of principle, preferred substrates are readily identified from substrate pools. Furthermore, this assay can be used to provide insight into the timing of tailoring events of biosynthetic pathways as demonstrated using the bromination reaction found on the jamaicamide biosynthetic pathway. Finally, this assay can provide insight into the role and function of orphan gene clusters for which the encoded natural product is unknown. This is demonstrated by identifying the substrates for two NRPS modules from the pksN and pksJ genes that are found on an orphan NRPS/PKS hybrid cluster from Bacillus subtilis. This new assay format is especially timely for activity screening in an era when new types of thiotemplate assembly lines that defy classification are being discovered at an accelerating rate.

  7. Early Adoption of a Multi-target Stool DNA Test for Colorectal Cancer Screening

    PubMed Central

    Finney Rutten, Lila J.; Jacobson, Robert M.; Wilson, Patrick M.; Jacobson, Debra J.; Fan, Chun; Kisiel, John B.; Sweetser, Seth R.; Tulledge-Scheitel, Sidna M.; St. Sauver, Jennifer L.

    2017-01-01

    Objective To characterize early adoption of a novelmulti-target stool deoxyribonucleic acid (MTsDNA) screening test for colorectal cancer (CRC) and test the hypothesis that adoption differs by demographic characteristics, prior CRC screening behavior, and proceeds predictably over time. Patients and Methods We used the Rochester Epidemiology Project infrastructure to assess MTsDNA screening test use among adults aged 50–75 years, and identified 27,147 individuals eligible/due for screening colonoscopy from November 1, 2014 through November 30, 2015, and living in Olmsted County, Minnesota in2014. We used electronic Current Procedure Terminology and Health Care Common Procedure codes to evaluate early adoption of MTsDNA screening test in this population and to test whether early adoption varies by age, sex, race, and prior screening behavior. Results Overall, 2,193 (8.1%) and 974 (3.6%) of individuals were screened by colonoscopy and MT-sDNA, respectively. Age, sex, race, and prior screening were significantly and independently associated with MT-sDNA screening use compared to colonoscopy use after adjustment for all other variables. Rates of adoption of MTsDNA screening increased over time and were highest among those aged 50–54 years, females, whites, and had a prior history of screening. MT-sDNA screening use varied predictably by insurance coverage. Rates of colonoscopy decreased over time, while overall CRC screening rates remained steady. Conclusion Our results are generally consistent with predictions derived from prior research and Diffusion of Innovation framework, pointing to increasing use of the new screening test over time, and early adoption by younger patients, females, whites and those with prior CRC screening. PMID:28473037

  8. Potential Biases Introduced by Conflating Screening and Diagnostic Testing in Colorectal Cancer Screening Surveillance

    PubMed Central

    Becker, Elizabeth A.; Griffith, Derek M.; West, Brady T.; Janz, Nancy K.; Resnicow, Ken; Morris, Arden M.

    2015-01-01

    Background Screening and post-symptomatic diagnostic testing are often conflated in cancer screening surveillance research. We examined the error in estimated colorectal cancer (CRC) screening prevalence due to the conflation of screening and diagnostic testing. Methods Using data from the 2008 National Health Interview Survey, we compared weighted prevalence estimates of the use of all testing (screening and diagnostic) and screening in at-risk adults, and calculated the overestimation of screening prevalence across socio-demographic groups. Results The population screening prevalence was overestimated by 23.3%, and the level of overestimation varied widely across socio-demographic groups (median 22.6%, mean 24.8%). The highest levels of overestimation were in non-Hispanic White females (27.4%), adults ages 50–54 (32.0%), and those with the highest socioeconomic vulnerability (low educational attainment (31.3%), low poverty ratio (32.5%), no usual source of health care (54.4%) and not insured (51.6%)) (all p-values < 0.001). Conclusions When the impetus for testing was not included, CRC screening prevalence was overestimated, and patterns of overestimation often aligned with social and economic vulnerability. These results are of concern to researchers who utilize survey data from the Behavioral Risk Factor Surveillance System (BRFSS) to assess cancer screening behaviors, as it is currently not designed to distinguish diagnostic testing from screening. Impact Surveillance research in cancer screening that does not consider the impetus for testing risks measurement error of screening prevalence, impeding progress toward improving population health. Ultimately, in order to craft relevant screening benchmarks and interventions, we must look beyond ‘what’ and ‘when’ and include ‘why.’ PMID:26491056

  9. Simplifying and expanding the screening for peptides <2 kDa by direct urine injection, liquid chromatography, and ion mobility mass spectrometry.

    PubMed

    Thomas, Andreas; Görgens, Christian; Guddat, Sven; Thieme, Detlef; Dellanna, Frank; Schänzer, Wilhelm; Thevis, Mario

    2016-01-01

    The analysis of low-molecular-mass peptides in doping controls has become a mandatory aspect in sports drug testing and, thus, the number of samples that has to be tested for these analytes has been steadily increasing. Several peptides <2 kDa with performance-enhancing properties are covered by the list of prohibited substances of the World Anti-Doping Agency including Desmopressin, LH-RH, Buserelin, Triptorelin, Leuprolide, GHRP-1, GHRP-2, GHRP-3, GHRP-4, GHRP-5,GHRP-6, Alexamorelin, Ipamorelin, Hexarelin, ARA-290, AOD-9604, TB-500 and Anamorelin. With the presented method employing direct urine injection into a liquid chromatograph followed by ion-mobility time-of-flight mass spectrometry, a facile, specific and sensitive assay for the aforementioned peptidic compounds is provided. The accomplished sensitivity allows for limits of detection between 50 and 500 pg/mL and thus covers the minimum required performance level of 2 ng/mL accordingly. The method is precise (imprecision <20%) and linear in the estimated working range between 0 and 10 ng/mL. The stability of the peptides in urine was tested, and -20°C was found to be the appropriate storage temperature for sports drug testing. Finally, proof-of-concept was shown by analysing elimination study urine samples collected from individuals having administered GHRP-6, GHRP-2, or LHRH. © 2015 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  10. Serum Metabonomics of Mild Acute Pancreatitis.

    PubMed

    Xu, Hongmin; Zhang, Lei; Kang, Huan; Zhang, Jiandong; Liu, Jie; Liu, Shuye

    2016-11-01

    Mild acute pancreatitis (MAP) is a common acute abdominal disease, and exhibits rising incidence in recent decades. As an important component of systemic biology, metabonomics is a new discipline developed following genomics and proteomics. In this study, the objective was to analyze the serum metabonomics of patients with MAP, aiming to screen metabolic markers with potential diagnostic values. An analysis platform with ultra performance liquid chromatography-high-resolution mass spectrometry was used to screen the difference metabolites related to MAP diagnosis and disease course monitoring. A total of 432 endogenous metabolites were screened out from 122 serum samples, and 49 difference metabolites were verified, among which 12 difference metabolites were identified by nonparametric test. After material identification, eight metabolites exhibited reliable results, and their levels in MAP serum were higher than those in healthy serum. Four metabolites exhibited gradual downward trend with treatment process going on, and the differences were statistically significant (P < 0.05). Metabonomic analysis has revealed eight metabolites with potential diagnostic values toward MAP, among which four metabolites can be used to monitor the disease course. © 2016 Wiley Periodicals, Inc.

  11. Skin Cancer Screening

    MedlinePlus

    ... may have serious side effects . False-negative test results can occur. Screening test results may appear to ... even if there are symptoms. False-positive test results can occur. Screening test results may appear to ...

  12. Glucose screening tests during pregnancy

    MedlinePlus

    Oral glucose tolerance test - pregnancy; OGTT - pregnancy; Glucose challenge test - pregnancy; Gestational diabetes - glucose screening ... first step, you will have a glucose screening test: You DO NOT need to prepare or change ...

  13. Broad screening and identification of β-agonists in feed and animal body fluid and tissues using ultra-high performance liquid chromatography-quadrupole-orbitrap high resolution mass spectrometry combined with spectra library search.

    PubMed

    Li, Tingting; Cao, Jingjing; Li, Zhen; Wang, Xian; He, Pingli

    2016-02-01

    Broad screening and identification of β-agonists in feed, serum, urine, muscle and liver samples was achieved in a quick and highly sensitive manner using ultra high performance liquid chromatography-quadrupole-orbitrap high resolution mass spectrometry (UHPLC-Q-Orbitrap HRMS) combined with a spectra library search. Solid-phase extraction technology was employed for sample purification and enrichment. After extraction and purification, the samples were analyzed using a Q-Orbitrap high-resolution mass spectrometer under full-scan and data-dependent MS/MS mode. The acquired mass spectra were compared with an in-house library (compound library and MS/MS mass spectral library) built with TraceFinder Software which contained the M/Z of the precursor ion, chemical formula, retention time, character fragment ions and the entire MS/MS spectra of 32 β-agonist standards. Screening was achieved by comparing 5 key mass spectral results and positive matches were marked. Using the developed method, the identification results from 10 spiked samples and 238 actual samples indicated that only 2% of acquired mass spectra produced false identities. The method validation results showed that the limit of detection ranged from 0.021-3.854 μg kg(-1)and 0.015-1.198 ng mL(-1) for solid and liquid samples, respectively. Copyright © 2015 Elsevier Ltd. All rights reserved.

  14. Cognitive Screening Tests Versus Comprehensive Neuropsychological Test Batteries: A National Academy of Neuropsychology Education Paper†.

    PubMed

    Roebuck-Spencer, Tresa M; Glen, Tannahill; Puente, Antonio E; Denney, Robert L; Ruff, Ronald M; Hostetter, Gayle; Bianchini, Kevin J

    2017-06-01

    The American Medical Association Current Procedural Panel developed a new billing code making behavioral health screening a reimbursable healthcare service. The use of computerized testing as a means for cognitive screening and brief cognitive testing is increasing at a rapid rate. The purpose of this education paper is to provide information to clinicians, healthcare administrators, and policy developers about the purpose, strengths, and limitations of cognitive screening tests versus comprehensive neuropsychological evaluations. Screening tests are generally brief and narrow in scope, they can be administered during a routine clinical visit, and they can be helpful for identifying individuals in need of more comprehensive assessment. Some screening tests can also be helpful for monitoring treatment outcomes. Comprehensive neuropsychological assessments are multidimensional in nature and used for purposes such as identifying primary and secondary diagnoses, determining the nature  and severity of a person's cognitive difficulties, determining functional limitations, and planning treatment and rehabilitation. Cognitive screening tests are expected to play an increasingly important role in identifying individuals with cognitive impairment and in determining which individuals should be referred for further neuropsychological assessment. However, limitations of existing cognitive screening tests are present and cognitive screening tests should not be used as a replacement for comprehensive neuropsychological testing. © The Author 2017. Published by Oxford University Press. All rights reserved. For permissions, please e-mail: journals.permissions@oup.com.

  15. Systematic forensic toxicological analysis by liquid-chromatography-quadrupole-time-of-flight mass spectrometry in serum and comparison to gas chromatography-mass spectrometry.

    PubMed

    Grapp, Marcel; Kaufmann, Christoph; Streit, Frank; Binder, Lutz

    2018-06-01

    Comprehensive screening procedures for psychoactive agents in body fluids are an essential task in clinical and forensic toxicology. With the continuous emergence and adaption of new psychoactive substances (NPS) keeping a screening method up to date is challenging. To meet these demands, hyphenated high-resolution mass spectrometry has gained interest as extensive and expandable screening approach. Here we present a comprehensive method for systematic toxicological analysis of serum by liquid chromatography-quadrupole-time-of-flight mass spectrometry (LC-QTOF-MS) with data independent acquisition. The potential of this method was demonstrated by analysis of 247 authentic serum- and 12 post-mortem femoral blood samples. Thus 950 compounds, comprising 185 different drugs and metabolites could be identified. For the detected substances, including pharmaceutical substances, illicit drugs as well as NPS, serum concentrations were confirmed ranging from traces to toxic values indicating the capability for forensic toxicological requirements. Positive identification of drugs was achieved by accurate mass measurement (±5ppm for [M+H] + ; ±10ppm for [M-H] - ), retention time (±0.35min), isotopic pattern match (less than 10 m/z RMS [ppm]), isotope match intensity (less than 20% RMS) and the presence of at least two fragment ions. The LC-QTOF-MS procedure was shown to be superior to serum screening by GC-MS, since 240% (335 versus 141) more drugs were identified in serum samples compared to GC-MS. Copyright © 2018 Elsevier B.V. All rights reserved.

  16. Screening tests for aphasia in patients with stroke: a systematic review.

    PubMed

    El Hachioui, Hanane; Visch-Brink, Evy G; de Lau, Lonneke M L; van de Sandt-Koenderman, Mieke W M E; Nouwens, Femke; Koudstaal, Peter J; Dippel, Diederik W J

    2017-02-01

    Aphasia has a large impact on the quality of life and adds significantly to the costs of stroke care. Early recognition of aphasia in stroke patients is important for prognostication and well-timed treatment planning. We aimed to identify available screening tests for differentiating between aphasic and non-aphasic stroke patients, and to evaluate test accuracy, reliability, and feasibility. We searched PubMed, EMbase, Web of Science, and PsycINFO for published studies on screening tests aimed at assessing aphasia in stroke patients. The reference lists of the selected articles were scanned, and several experts were contacted to detect additional references. Of each screening test, we estimated the sensitivity, specificity, likelihood ratio of a positive test, likelihood ratio of a negative test, and diagnostic odds ratio (DOR), and rated the degree of bias of the validation method. We included ten studies evaluating eight screening tests. There was a large variation across studies regarding sample size, patient characteristics, and reference tests used for validation. Many papers failed to report on the consecutiveness of patient inclusion, time between aphasia onset and administration of the screening test, and blinding. Of the three studies that were rated as having an intermediate or low risk of bias, the DOR was highest for the Language Screening Test and ScreeLing. Several screening tools for aphasia in stroke are available, but many tests have not been verified properly. Methodologically sound validation studies of aphasia screening tests are needed to determine their usefulness in clinical practice.

  17. 42 CFR 410.37 - Colorectal cancer screening tests: Conditions for and limitations on coverage.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 42 Public Health 2 2010-10-01 2010-10-01 false Colorectal cancer screening tests: Conditions for...) BENEFITS Medical and Other Health Services § 410.37 Colorectal cancer screening tests: Conditions for and...) Colorectal cancer screening tests means any of the following procedures furnished to an individual for the...

  18. 42 CFR 410.37 - Colorectal cancer screening tests: Conditions for and limitations on coverage.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 42 Public Health 2 2011-10-01 2011-10-01 false Colorectal cancer screening tests: Conditions for...) BENEFITS Medical and Other Health Services § 410.37 Colorectal cancer screening tests: Conditions for and...) Colorectal cancer screening tests means any of the following procedures furnished to an individual for the...

  19. 42 CFR 410.37 - Colorectal cancer screening tests: Conditions for and limitations on coverage.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... 42 Public Health 2 2013-10-01 2013-10-01 false Colorectal cancer screening tests: Conditions for...) BENEFITS Medical and Other Health Services § 410.37 Colorectal cancer screening tests: Conditions for and...) Colorectal cancer screening tests means any of the following procedures furnished to an individual for the...

  20. 42 CFR 410.37 - Colorectal cancer screening tests: Conditions for and limitations on coverage.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... 42 Public Health 2 2012-10-01 2012-10-01 false Colorectal cancer screening tests: Conditions for...) BENEFITS Medical and Other Health Services § 410.37 Colorectal cancer screening tests: Conditions for and...) Colorectal cancer screening tests means any of the following procedures furnished to an individual for the...

Top