Sample records for master curve method

  1. A systematic methodology for creep master curve construction using the stepped isostress method (SSM): a numerical assessment

    NASA Astrophysics Data System (ADS)

    Miranda Guedes, Rui

    2018-02-01

    Long-term creep of viscoelastic materials is experimentally inferred through accelerating techniques based on the time-temperature superposition principle (TTSP) or on the time-stress superposition principle (TSSP). According to these principles, a given property measured for short times at a higher temperature or higher stress level remains the same as that obtained for longer times at a lower temperature or lower stress level, except that the curves are shifted parallel to the horizontal axis, matching a master curve. These procedures enable the construction of creep master curves with short-term experimental tests. The Stepped Isostress Method (SSM) is an evolution of the classical TSSP method. Higher reduction of the required number of test specimens to obtain the master curve is achieved by the SSM technique, since only one specimen is necessary. The classical approach, using creep tests, demands at least one specimen per each stress level to produce a set of creep curves upon which TSSP is applied to obtain the master curve. This work proposes an analytical method to process the SSM raw data. The method is validated using numerical simulations to reproduce the SSM tests based on two different viscoelastic models. One model represents the viscoelastic behavior of a graphite/epoxy laminate and the other represents an adhesive based on epoxy resin.

  2. The viscoelastic behavior of a composite in a thermal environment

    NASA Technical Reports Server (NTRS)

    Morris, D. H.; Brinson, H. F.; Griffith, W. I.; Yeow, Y. T.

    1979-01-01

    A proposed method for the accelerated predictions of modulus and life times for time dependent polymer matrix composite laminates is presented. The method, based on the time temperature superposition principle and lamination theory, is described in detail. Unidirectional reciprocal of compliance master curves and the shift functions needed are presented and discussed. Master curves for arbitrarily oriented unidirectional laminates are predicted and compared with experimantal results obtained from master curves generated from 15 minute tests and with 25 hour tests. Good agreement is shown. Predicted 30 deg and 60 deg unidirectional strength master curves are presented and compared to results of creep rupture tests. Reasonable agreement is demonstrated. In addition, creep rupture results for a (90 deg + or - 60 deg/90 deg) sub 2s laminate are presented.

  3. Spectro-photometric determinations of Mn, Fe and Cu in aluminum master alloys

    NASA Astrophysics Data System (ADS)

    Rehan; Naveed, A.; Shan, A.; Afzal, M.; Saleem, J.; Noshad, M. A.

    2016-08-01

    Highly reliable, fast and cost effective Spectro-photometric methods have been developed for the determination of Mn, Fe & Cu in aluminum master alloys, based on the development of calibration curves being prepared via laboratory standards. The calibration curves are designed so as to induce maximum sensitivity and minimum instrumental error (Mn 1mg/100ml-2mg/100ml, Fe 0.01mg/100ml-0.2mg/100ml and Cu 2mg/100ml-10mg/ 100ml). The developed Spectro-photometric methods produce accurate results while analyzing Mn, Fe and Cu in certified reference materials. Particularly, these methods are suitable for all types of Al-Mn, Al-Fe and Al-Cu master alloys (5%, 10%, 50% etc. master alloys).Moreover, the sampling practices suggested herein include a reasonable amount of analytical sample, which truly represent the whole lot of a particular master alloy. Successive dilution technique was utilized to meet the calibration curve range. Furthermore, the workout methods were also found suitable for the analysis of said elements in ordinary aluminum alloys. However, it was observed that Cush owed a considerable interference with Fe, the later one may not be accurately measured in the presence of Cu greater than 0.01 %.

  4. Statistical Analyses for Probabilistic Assessments of the Reactor Pressure Vessel Structural Integrity: Building a Master Curve on an Extract of the 'Euro' Fracture Toughness Dataset, Controlling Statistical Uncertainty for Both Mono-Temperature and multi-temperature tests

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Josse, Florent; Lefebvre, Yannick; Todeschini, Patrick

    2006-07-01

    Assessing the structural integrity of a nuclear Reactor Pressure Vessel (RPV) subjected to pressurized-thermal-shock (PTS) transients is extremely important to safety. In addition to conventional deterministic calculations to confirm RPV integrity, Electricite de France (EDF) carries out probabilistic analyses. Probabilistic analyses are interesting because some key variables, albeit conventionally taken at conservative values, can be modeled more accurately through statistical variability. One variable which significantly affects RPV structural integrity assessment is cleavage fracture initiation toughness. The reference fracture toughness method currently in use at EDF is the RCCM and ASME Code lower-bound K{sub IC} based on the indexing parameter RT{submore » NDT}. However, in order to quantify the toughness scatter for probabilistic analyses, the master curve method is being analyzed at present. Furthermore, the master curve method is a direct means of evaluating fracture toughness based on K{sub JC} data. In the framework of the master curve investigation undertaken by EDF, this article deals with the following two statistical items: building a master curve from an extract of a fracture toughness dataset (from the European project 'Unified Reference Fracture Toughness Design curves for RPV Steels') and controlling statistical uncertainty for both mono-temperature and multi-temperature tests. Concerning the first point, master curve temperature dependence is empirical in nature. To determine the 'original' master curve, Wallin postulated that a unified description of fracture toughness temperature dependence for ferritic steels is possible, and used a large number of data corresponding to nuclear-grade pressure vessel steels and welds. Our working hypothesis is that some ferritic steels may behave in slightly different ways. Therefore we focused exclusively on the basic french reactor vessel metal of types A508 Class 3 and A 533 grade B Class 1, taking the sampling level and direction into account as well as the test specimen type. As for the second point, the emphasis is placed on the uncertainties in applying the master curve approach. For a toughness dataset based on different specimens of a single product, application of the master curve methodology requires the statistical estimation of one parameter: the reference temperature T{sub 0}. Because of the limited number of specimens, estimation of this temperature is uncertain. The ASTM standard provides a rough evaluation of this statistical uncertainty through an approximate confidence interval. In this paper, a thorough study is carried out to build more meaningful confidence intervals (for both mono-temperature and multi-temperature tests). These results ensure better control over uncertainty, and allow rigorous analysis of the impact of its influencing factors: the number of specimens and the temperatures at which they have been tested. (authors)« less

  5. Master curve characterization of the fracture toughness behavior in SA508 Gr.4N low alloy steels

    NASA Astrophysics Data System (ADS)

    Lee, Ki-Hyoung; Kim, Min-Chul; Lee, Bong-Sang; Wee, Dang-Moon

    2010-08-01

    The fracture toughness properties of the tempered martensitic SA508 Gr.4N Ni-Mo-Cr low alloy steel for reactor pressure vessels were investigated by using the master curve concept. These results were compared to those of the bainitic SA508 Gr.3 Mn-Mo-Ni low alloy steel, which is a commercial RPV material. The fracture toughness tests were conducted by 3-point bending with pre-cracked charpy (PCVN) specimens according to the ASTM E1921-09c standard method. The temperature dependency of the fracture toughness was steeper than those predicted by the standard master curve, while the bainitic SA508 Gr.3 steel fitted well with the standard prediction. In order to properly evaluate the fracture toughness of the Gr.4N steels, the exponential coefficient of the master curve equation was changed and the modified curve was applied to the fracture toughness test results of model alloys that have various chemical compositions. It was found that the modified curve provided a better description for the overall fracture toughness behavior and adequate T0 determination for the tempered martensitic SA508 Gr.4N steels.

  6. Age dependence of Olympic weightlifting ability.

    PubMed

    Meltzer, D E

    1994-08-01

    There is increasing interest among Masters athletes in standards for comparing performances of competitors of different ages. The goal of this study was to develop one such age-comparison method by examining the age dependence of ability in Olympic-style weightlifting. Previous research on the deterioration of muscular strength and power with increasing age offers only limited guidance toward this goal; therefore, analysis of performance data was required. The variation of weightlifting ability as a function of age was examined by two different methods. First, cross-sectional data corresponding to two separate populations of Masters weightlifters were analyzed in detail. Then, a longitudinal study of 64 U.S. male Masters weightlifters was carried out, with performance versus age curves resulting from the two methods were very similar, reflecting approximately 1.0-1.5% x yr-1 deterioration rates. These curves were characterized by common features regarding the rate of decline of muscular power with increasing age, in apparent agreement with published data regarding Masters sprinters and jumpers. We tentatively conclude that Olympic weightlifting ability in trained subjects undergoes a nonlinear decline with age, in which the second derivative of the performance versus age curve repeatedly changes sign.

  7. Continuous relaxation and retardation spectrum method for viscoelastic characterization of asphalt concrete

    NASA Astrophysics Data System (ADS)

    Bhattacharjee, Sudip; Swamy, Aravind Krishna; Daniel, Jo S.

    2012-08-01

    This paper presents a simple and practical approach to obtain the continuous relaxation and retardation spectra of asphalt concrete directly from the complex (dynamic) modulus test data. The spectra thus obtained are continuous functions of relaxation and retardation time. The major advantage of this method is that the continuous form is directly obtained from the master curves which are readily available from the standard characterization tests of linearly viscoelastic behavior of asphalt concrete. The continuous spectrum method offers efficient alternative to the numerical computation of discrete spectra and can be easily used for modeling viscoelastic behavior. In this research, asphalt concrete specimens have been tested for linearly viscoelastic characterization. The linearly viscoelastic test data have been used to develop storage modulus and storage compliance master curves. The continuous spectra are obtained from the fitted sigmoid function of the master curves via the inverse integral transform. The continuous spectra are shown to be the limiting case of the discrete distributions. The continuous spectra and the time-domain viscoelastic functions (relaxation modulus and creep compliance) computed from the spectra matched very well with the approximate solutions. It is observed that the shape of the spectra is dependent on the master curve parameters. The continuous spectra thus obtained can easily be implemented in material mix design process. Prony-series coefficients can be easily obtained from the continuous spectra and used in numerical analysis such as finite element analysis.

  8. New method for calculating a mathematical expression for streamflow recession

    USGS Publications Warehouse

    Rutledge, Albert T.

    1991-01-01

    An empirical method has been devised to calculate the master recession curve, which is a mathematical expression for streamflow recession during times of negligible direct runoff. The method is based on the assumption that the storage-delay factor, which is the time per log cycle of streamflow recession, varies linearly with the logarithm of streamflow. The resulting master recession curve can be nonlinear. The method can be executed by a computer program that reads a data file of daily mean streamflow, then allows the user to select several near-linear segments of streamflow recession. The storage-delay factor for each segment is one of the coefficients of the equation that results from linear least-squares regression. Using results for each recession segment, a mathematical expression of the storage-delay factor as a function of the log of streamflow is determined by linear least-squares regression. The master recession curve, which is a second-order polynomial expression for time as a function of log of streamflow, is then derived using the coefficients of this function.

  9. A new experimental method for the accelerated characterization of composite materials

    NASA Technical Reports Server (NTRS)

    Brinson, H. F.; Morris, D. H.; Yeow, Y. T.

    1978-01-01

    A method which permits the prediction of long-term properties of graphite/epoxy laminates on the basis of short-term (15 min) laboratory tests is described. Demonstration of delayed viscoelastic fracture in one laminate configuration, and data on the time and temperature response of a matrix-dominated unidirectional laminate contributed to a characterization of the viscoelastic process in the graphite/epoxy composites. Master curves from short-term tests of certain laminate configurations can be employed to generate long-term master curves. In addition, analytical predictions from short-term results can be used to predict long-term (25-hour) laminate properties.

  10. Nondestructive evaluation of the complex modulus master curve of asphalt concrete specimens

    NASA Astrophysics Data System (ADS)

    Gudmarsson, A.; Ryden, N.; Birgisson, B.

    2013-01-01

    The dynamic Young's modulus of asphalt concrete is directly related to pavement quality and is used in thickness design of pavements. There is a need for a nondestructive laboratory method to evaluate the complex modulus, which can be linked to nondestructive field measurements. This study applies seismic measurements to an asphalt concrete beam where resonant acoustic spectroscopy and optimization of frequency response functions are used to estimate the complex moduli. A good estimation of the master curve is obtained.

  11. A Hierarchical Modeling for Reactive Power Optimization With Joint Transmission and Distribution Networks by Curve Fitting

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Ding, Tao; Li, Cheng; Huang, Can

    Here, in order to solve the reactive power optimization with joint transmission and distribution networks, a hierarchical modeling method is proposed in this paper. It allows the reactive power optimization of transmission and distribution networks to be performed separately, leading to a master–slave structure and improves traditional centralized modeling methods by alleviating the big data problem in a control center. Specifically, the transmission-distribution-network coordination issue of the hierarchical modeling method is investigated. First, a curve-fitting approach is developed to provide a cost function of the slave model for the master model, which reflects the impacts of each slave model. Second,more » the transmission and distribution networks are decoupled at feeder buses, and all the distribution networks are coordinated by the master reactive power optimization model to achieve the global optimality. Finally, numerical results on two test systems verify the effectiveness of the proposed hierarchical modeling and curve-fitting methods.« less

  12. A Hierarchical Modeling for Reactive Power Optimization With Joint Transmission and Distribution Networks by Curve Fitting

    DOE PAGES

    Ding, Tao; Li, Cheng; Huang, Can; ...

    2017-01-09

    Here, in order to solve the reactive power optimization with joint transmission and distribution networks, a hierarchical modeling method is proposed in this paper. It allows the reactive power optimization of transmission and distribution networks to be performed separately, leading to a master–slave structure and improves traditional centralized modeling methods by alleviating the big data problem in a control center. Specifically, the transmission-distribution-network coordination issue of the hierarchical modeling method is investigated. First, a curve-fitting approach is developed to provide a cost function of the slave model for the master model, which reflects the impacts of each slave model. Second,more » the transmission and distribution networks are decoupled at feeder buses, and all the distribution networks are coordinated by the master reactive power optimization model to achieve the global optimality. Finally, numerical results on two test systems verify the effectiveness of the proposed hierarchical modeling and curve-fitting methods.« less

  13. Creep rupture of polymer-matrix composites

    NASA Technical Reports Server (NTRS)

    Brinson, H. F.; Morris, D. H.; Griffith, W. I.

    1981-01-01

    The time-dependent creep-rupture process in graphite-epoxy laminates is examined as a function of temperature and stress level. Moisture effects are not considered. An accelerated characterization method of composite-laminate viscoelastic modulus and strength properties is reviewed. It is shown that lamina-modulus master curves can be obtained using a minimum of normally performed quality-control-type testing. Lamina-strength master curves, obtained by assuming a constant-strain-failure criterion, are presented along with experimental data, and reasonably good agreement is shown to exist between the two. Various phenomenological delayed failure models are reviewed and two (the modified rate equation and the Larson-Miller parameter method) are compared to creep-rupture data with poor results.

  14. A geometry-based approach to determining time-temperature superposition shifts in aging experiments

    DOE PAGES

    Maiti, Amitesh

    2015-12-21

    A powerful way to expand the time and frequency range of material properties is through a method called time-temperature superposition (TTS). Traditionally, TTS has been applied to the dynamical mechanical and flow properties of thermo-rheologically simple materials, where a well-defined master curve can be objectively and accurately obtained by appropriate shifts of curves at different temperatures. However, TTS analysis can also be useful in many other situations where there is scatter in the data and where the principle holds only approximately. In such cases, shifting curves can become a subjective exercise and can often lead to significant errors in themore » long-term prediction. This mandates the need for an objective method of determining TTS shifts. Here, we adopt a method based on minimizing the “arc length” of the master curve, which is designed to work in situations where there is overlapping data at successive temperatures. We examine the accuracy of the method as a function of increasing noise in the data, and explore the effectiveness of data smoothing prior to TTS shifting. In conclusion, we validate the method using existing experimental data on the creep strain of an aramid fiber and the powder coarsening of an energetic material.« less

  15. Fracture toughness testing of Linde 1092 reactor vessel welds in the transition range using Charpy-sized specimens

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Pavinich, W.A.; Yoon, K.K.; Hour, K.Y.

    1999-10-01

    The present reference toughness method for predicting the change in fracture toughness can provide over estimates of these values because of uncertainties in initial RT{sub NDT} and shift correlations. It would be preferable to directly measure fracture toughness. However, until recently, no standard method was available to characterize fracture toughness in the transition range. ASTM E08 has developed a draft standard that shows promise for providing lower bound transition range fracture toughness using the master curve approach. This method has been successfully implemented using 1T compact fracture specimens. Combustion Engineering reactor vessel surveillance programs do not have compact fracture specimens.more » Therefore, the CE Owners Group developed a program to validate the master curve method for Charpy-sized and reconstituted Charpy-sized specimens for future application on irradiated specimens. This method was validated for Linde 1092 welds using unirradiated Charpy-sized and reconstituted Charpy-sized specimens by comparison of results with those from compact fracture specimens.« less

  16. Semi-empirical master curve concept describing the rate capability of lithium insertion electrodes

    NASA Astrophysics Data System (ADS)

    Heubner, C.; Seeba, J.; Liebmann, T.; Nickol, A.; Börner, S.; Fritsch, M.; Nikolowski, K.; Wolter, M.; Schneider, M.; Michaelis, A.

    2018-03-01

    A simple semi-empirical master curve concept, describing the rate capability of porous insertion electrodes for lithium-ion batteries, is proposed. The model is based on the evaluation of the time constants of lithium diffusion in the liquid electrolyte and the solid active material. This theoretical approach is successfully verified by comprehensive experimental investigations of the rate capability of a large number of porous insertion electrodes with various active materials and design parameters. It turns out, that the rate capability of all investigated electrodes follows a simple master curve governed by the time constant of the rate limiting process. We demonstrate that the master curve concept can be used to determine optimum design criteria meeting specific requirements in terms of maximum gravimetric capacity for a desired rate capability. The model further reveals practical limits of the electrode design, attesting the empirically well-known and inevitable tradeoff between energy and power density.

  17. Deviations in expected price impact for small transaction volumes under fee restructuring

    NASA Astrophysics Data System (ADS)

    Harvey, M.; Hendricks, D.; Gebbie, T.; Wilcox, D.

    2017-04-01

    We report on the occurrence of an anomaly in the price impacts of small transaction volumes following a change in the fee structure of an electronic market. We first review evidence for the existence of a master curve for price impact on the Johannesburg Stock Exchange (JSE). On attempting to re-estimate a master curve after fee reductions, it is found that the price impact corresponding to smaller volume trades is greater than expected relative to prior estimates for a range of listed stocks. We show that a master curve for price impact can be found following rescaling by an appropriate liquidity proxy, providing a means for practitioners to approximate price impact curves without onerous processing of tick data.

  18. Expression, crosslinking, and developing modulus master curves of recombinant resilin.

    PubMed

    Khandaker, Md Shahriar K; Dudek, Daniel M; Beers, Eric P; Dillard, David A

    2017-05-01

    Resilin is a disordered elastomeric protein found in specialized regions of insect cuticles, where low stiffness and high resilience are required. Having a wide range of functions that vary among insect species, resilin operates across a wide frequency range, from 5Hz for locomotion to 13kHz for sound production. We synthesize and crosslink a recombinant resilin from clone-1 (exon-1+exon-2) of the gene, and determine the water content (approximately 80wt%) and dynamic mechanical properties, along with estimating surface energies relevant for adhesion. Dynamic moduli master curves have been developed, by applying the time-temperature superposition principle (TTSP) and time-temperature concentration superposition principle (TTCSP), and compared with reported master curves for natural resilin from locusts, dragonflies, and cockroaches. To our knowledge, this is the first time dynamic moduli master curves have been developed to explore the dynamic mechanical properties of recombinant resilin and compare with resilin behavior. The resulting master curves show that the synthetic resilin undergoes a pronounced transition with increasing ethanol concentrations, with the storage modulus increasing by approximately three orders of magnitude. Although possibly a glass transition, alternate explanations include the formation of intramolecular hydrogen bonds or that the chitin binding domain (ChBD) in exon-2 might change the secondary structure of the normally disordered exon-1 into more ordered conformations that limit deformation. Copyright © 2017 Elsevier Ltd. All rights reserved.

  19. Two-particle microrheology of quasi-2D viscous systems.

    PubMed

    Prasad, V; Koehler, S A; Weeks, Eric R

    2006-10-27

    We study the spatially correlated motions of colloidal particles in a quasi-2D system (human serum albumin protein molecules at an air-water interface) for different surface viscosities eta s. We observe a transition in the behavior of the correlated motion, from 2D interface dominated at high eta s to bulk fluid dependent at low eta s. The correlated motions can be scaled onto a master curve which captures the features of this transition. This master curve also characterizes the spatial dependence of the flow field of a viscous interface in response to a force. The scale factors used for the master curve allow for the calculation of the surface viscosity eta s that can be compared to one-particle measurements.

  20. Study on viscosity of conventional and polymer modified asphalt binders in steady and dynamic shear domain

    NASA Astrophysics Data System (ADS)

    Saboo, Nikhil; Singh, Bhupendra; Kumar, Praveen; Vikram, Durgesh

    2018-02-01

    This study focuses on evaluating the flow behavior of conventional and polymer modified asphalt binders in steady- and dynamic-shear domain, for a temperature range of 20-70 °C, using a Dynamic Shear Rheometer (DSR). Steady-shear viscosity and frequency sweep tests were carried out on two conventional (VG 10 and VG 30) and two polymer (SBS and EVA) modified asphalt binders. Applicability of the Cox-Merz principle was evaluated and complex viscosity master curves were analyzed at five different reference temperatures. Cross model was used to simulate the complex viscosity master curves at different temperatures. It was found that asphalt binders exhibited shear-thinning behavior at all the test temperatures. The critical shear rate increased with increase in temperature and was found to be lowest for plastomeric modified asphalt binder. The Cox-Merz principle was found to be valid in the zero-shear viscosity (ZSV) domain and deviated at higher frequency/shear rate for all the binders. Results from the study indicated that the ratio of ZSV can be successfully used as shift factors for construction of master curves at different reference temperatures. Cross model was found to be suitable in simulating the complex viscosity master curves at all the test temperatures. Analysis of model parameters indicated that a strong relationship exists between ZSV and the critical shear rate. ZSV and critical shear rate varied exponentially with temperature. This relationship was used to propose a simple equation for assessing the shift factors for construction of master curves.

  1. Direct manipulation of tool-like masters for controlling a master-slave surgical robotic system.

    PubMed

    Zhang, Linan; Zhou, Ningxin; Wang, Shuxin

    2014-12-01

    Robotic-assisted minimally invasive surgery (MIS) can benefit both patients and surgeons. However, the learning curve for robotically assisted procedures can be long and the total system costs are high. Therefore, there is considerable interest in new methods and lower cost controllers for a surgical robotic system. In this study, a knife-master and a forceps-master, shaped similarly to a surgical knife and forceps, were developed as input devices for control of a master-slave surgical robotic system. In addition, a safety strategy was developed to eliminate the master-slave orientation difference and stabilize the surgical system. Master-slave tracking experiments and a ring-and-bar experiment showed that the safety tracking strategy could ensure that the robot system moved stably without any tremor in the tracking motion. Subjects could manipulate the surgical tool to achieve the master-slave operation with less training compared to a mechanical master. Direct manipulation of the small, light and low-cost surgical tools to control a robotic system is a possible operating mode. Surgeons can operate the robotic system in their own familiar way, without long training. The main potential safety issues can be solved by the proposed safety control strategy. Copyright © 2013 John Wiley & Sons, Ltd.

  2. Offline motion planning and simulation of two-robot welding coordination

    NASA Astrophysics Data System (ADS)

    Zhang, Tie; Ouyang, Fan

    2012-03-01

    This paper focuses on the two-robot welding coordination of complex curve seam which means one robot grasp the workpiece, the other hold the torch, the two robots work on the same workpiece simultaneously. This paper builds the dual-robot coordinate system at the beginning, and three point calibration method of two robots' relative base coordinate system is presented. After that, the non master/slave scheme is chosen for the motion planning, the non master/slave scheme sets the poses versus time function of the point u on the workpiece, and calculates the two robot end effecter trajectories through the constrained relationship matrix automatically. Moreover, downhand welding is employed which can guarantee the torch and the seam keep in good contact condition all the time during the welding. Finally, a Solidworks-Sim Mechanics simulation platform is established, and a simulation of curved steel pipe welding is conducted. The results of the simulation illustrate the welding process can meet the requirements of downhand welding, the joint displacement curves are smooth and continuous and no joint velocities are out of working scope.

  3. Creep-rupture of polymer-matrix composites. [graphite-epoxy laminates

    NASA Technical Reports Server (NTRS)

    Brinson, H. F.; Griffith, W. I.; Morris, D. H.

    1980-01-01

    An accelerated characterization method for resin matrix composites is reviewed. Methods for determining modulus and strength master curves are given. Creep rupture analytical models are discussed as applied to polymers and polymer matrix composites. Comparisons between creep rupture experiments and analytical models are presented. The time dependent creep rupture process in graphite epoxy laminates is examined as a function of temperature and stress level.

  4. Radiation and annealing response of WWER 440 beltline welding seams

    NASA Astrophysics Data System (ADS)

    Viehrig, Hans-Werner; Houska, Mario; Altstadt, Eberhard

    2015-01-01

    The focus of this paper is on the irradiation response and the effect of thermal annealing in weld materials extracted from decommissioned WWER 440 reactor pressure vessels of the nuclear power plant Greifswald. The characterisation is based on the measurement of the hardness, the yield stress, the Master Curve reference temperature, T0, and the Charpy-V transition temperature through the thickness of multi-layer beltline welding seams in the irradiated and the thermally annealed condition. Additionally, the weld bead structure was characterised by light microscopic studies. We observed a large variation in the through thickness T0 values in the irradiated as well as in thermally annealed condition. The T0 values measured with the T-S-oriented Charpy size SE(B) specimens cut from different thickness locations of the multilayer welding seams strongly depend on the intrinsic weld bead structure along the crack tip. The Master Curve, T0, and Charpy-V, TT47J, based ductile-to-brittle transition temperature progressions through the thickness of the multi-layer welding seam do not correspond to the forecast according to the Russian code. In general, the fracture toughness values at cleavage failure, KJc, measured on SE(B) specimens from the irradiated and large-scale thermally annealed beltline welding seams follow the Master Curve description, but more than the expected number lie outside the curves for 2% and 98% fracture probability. In this case the test standard ASTM E1921 indicates the investigated multi-layer weld metal as not uniform. The multi modal Master Curve based approach describes the temperature dependence of the specimen size adjusted KJc-1T values well. Thermal annealing at 475 °C for 152 h results in the expected decrease of the hardness and tensile strength and the shift of Master Curve and Charpy-V based ductile-to-brittle transition temperatures to lower values.

  5. Interpretation of magnetotelluric resistivity and phase soundings over horizontal layers

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Patella, D.

    1976-02-01

    The present paper deals with a new inverse method for quantitatively interpreting magnetotelluric apparent resistivity and phase-lag sounding curves over horizontally stratified earth sections. The recurrent character of the general formula relating the wave impedance of an (n-l)-layered medium to that of an n-layered medium suggests the use of the method of reduction to a lower boundary plane, as originally termed by Koefoed in the case of dc resistivity soundings. The layering parameters are so directly derived by a simple iterative procedure. The method is applicable for any number of layers but only when both apparent resistivity and phase-lag soundingmore » curves are jointly available. Moreover no sophisticated algorithm is required: a simple desk electronic calculator together with a sheet of two-layer apparent resistivity and phase-lag master curves are sufficient to reproduce earth sections which, in the range of equivalence, are all consistent with field data.« less

  6. Time-Temperature Superposition to Determine the Stress-Rupture of Aramid Fibres

    NASA Astrophysics Data System (ADS)

    Alwis, K. G. N. C.; Burgoyne, C. J.

    2006-07-01

    Conventional creep testing takes a long time to obtain stress-rupture data for aramid fibres at the low stress levels likely to be used in practical applications. However, the rate of creep of aramid can be accelerated by a thermally activated process to obtain the failure of fibres within a few hours. It is possible to obtain creep curves at different temperature levels which can be shifted along the time axis to generate a single curve know as a master curve, from which stress-rupture data can be obtained. This technique is known as the time-temperature superposition principle and will be applied to Kevlar 49 yarns. Important questions relating to the techniques needed to obtain smooth master curves will be discussed, as will the validity the resulting curves and the corresponding stress-rupture lifetime.

  7. Lifetime Prediction of Nano-Silica based Glass Fibre/Epoxy composite by Time Temperature Superposition Principle

    NASA Astrophysics Data System (ADS)

    Anand, Abhijeet; Banerjee, Poulami; Prusty, Rajesh Kumar; Ray, Bankin Chandra

    2018-03-01

    The incorporation of nano fillers in Fibre reinforced polymer (FRP) composites has been a source of experimentation for researchers. Addition of nano fillers has been found to improve mechanical, thermal as well as electrical properties of Glass fibre reinforced polymer (GFRP) composites. The in-plane mechanical properties of GFRP composite are mainly controlled by fibers and therefore exhibit good values. However, composite exhibits poor through-thickness properties, in which the matrix and interface are the dominant factors. Therefore, it is conducive to modify the matrix through dispersion of nano fillers. Creep is defined as the plastic deformation experienced by a material for a temperature at constant stress over a prolonged period of time. Determination of Master Curve using time-temperature superposition principle is conducive for predicting the lifetime of materials involved in naval and structural applications. This is because such materials remain in service for a prolonged time period before failure which is difficult to be kept marked. However, the failure analysis can be extrapolated from its behaviour in a shorter time at an elevated temperature as is done in master creep analysis. The present research work dealt with time-temperature analysis of 0.1% SiO2-based GFRP composites fabricated through hand-layup method. Composition of 0.1% for SiO2nano fillers with respect to the weight of the fibers was observed to provide optimized flexural properties. Time and temperature dependence of flexural properties of GFRP composites with and without nano SiO2 was determined by conducting 3-point bend flexural creep tests over a range of temperature. Stepwise isothermal creep tests from room temperature (30°C) to the glass transition temperature Tg (120°C) were performed with an alternative creep/relaxation period of 1 hour at each temperature. A constant stress of 40MPa was applied during the creep tests. The time-temperature superposition principle was followed while determining the Master Curve and cumulative damage law. The purpose of a Master Curve was to determine the variation of compliance with respect to increase in time and temperature of the specimen. The shift factors at any reference temperature were determined by Arrhenius activation energy method at a far lower temperature than Tg (Glass transition temperature) and by manual shift method at a temperature near Tg (Glass transition temperature).

  8. Universal features of fluctuations in globular proteins.

    PubMed

    Erman, Burak

    2016-06-01

    Using data from 2000 non-homologous protein crystal structures, we show that the distribution of residue B factors of proteins collapses onto a single master curve. We show by maximum entropy arguments that this curve is a Gamma function whose order and dispersion are obtained from experimental data. The distribution for any given specific protein can be generated from the master curve by a linear transformation. Any perturbation of the B factor distribution of a protein, imposed at constant energy, causes a decrease in the entropy of the protein relative to that of the reference state. Proteins 2016; 84:721-725. © 2016 Wiley Periodicals, Inc. © 2016 Wiley Periodicals, Inc.

  9. A two step method to treat variable winds in fallout smearing codes. Master's thesis

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Hopkins, A.T.

    1982-03-01

    A method was developed to treat non-constant winds in fallout smearing codes. The method consists of two steps: (1) location of the curved hotline (2) determination of the off-hotline activity. To locate the curved hotline, the method begins with an initial cloud of 20 discretely-sized pancake clouds, located at altitudes determined by weapon yield. Next, the particles are tracked through a 300 layer atmosphere, translating with different winds in each layer. The connection of the 20 particles' impact points is the fallout hotline. The hotline location was found to be independent of the assumed particle size distribution in the stabilizedmore » cloud. The off-hotline activity distribution is represented as a two-dimensional gaussian function, centered on the curved hotline. Hotline locator model results were compared to numerical calculations of hypothetical 100 kt burst and to the actual hotline produced by the Castle-Bravo 15 Mt nuclear test.« less

  10. Non-Boltzmann Modeling for Air Shock-Layer Radiation at Lunar-Return Conditions

    NASA Technical Reports Server (NTRS)

    Johnston, Christopher O.; Hollis, Brian R.; Sutton, Kenneth

    2008-01-01

    This paper investigates the non-Boltzmann modeling of the radiating atomic and molecular electronic states present in lunar-return shock-layers. The Master Equation is derived for a general atom or molecule while accounting for a variety of excitation and de-excitation mechanisms. A new set of electronic-impact excitation rates is compiled for N, O, and N2+, which are the main radiating species for most lunar-return shock-layers. Based on these new rates, a novel approach of curve-fitting the non-Boltzmann populations of the radiating atomic and molecular states is developed. This new approach provides a simple and accurate method for calculating the atomic and molecular non-Boltzmann populations while avoiding the matrix inversion procedure required for the detailed solution of the Master Equation. The radiative flux values predicted by the present detailed non-Boltzmann model and the approximate curve-fitting approach are shown to agree within 5% for the Fire 1634 s case.

  11. Characterization of viscoelastic response and damping of composite materials used in flywheel rotors

    NASA Astrophysics Data System (ADS)

    Chen, Jianmin

    The long-term goal for spacecraft flywheel systems with higher energy density at the system level requires new and innovative composite material concepts. Multi-Direction Composite (MDC) offers significant advantages over traditional filament-wound and multi-ring press-fit filament-wound wheels in providing higher energy density (i.e., less mass), better crack resistance, and enhanced safety. However there is a lack of systematic characterization for dynamic properties of MDC composite materials. In order to improve the flywheel materials reliability, durability and life time, it is very important to evaluate the time dependent aging effects and damping properties of MDC material, which are significant dynamic parameter for vibration and sound control, fatigue endurance, and impact resistance. The physical aging effects are quantified based on a set of creep curves measured at different aging time or different aging temperature. One parameter (tau) curve fit was proposed to represent the relationship of aging time and aging temperature between different master curves. The long term mechanical behavior was predicted by obtained master curves. The time and temperature shift factors of matrix were obtained from creep curves and the aging time shift rate were calculated. The aging effects on composite are obtained from experiments and compared with prediction. The mechanical quasi-behavior of MDC composite was analyzed. The correspondence principle was used to relate quasi-static elastic properties of composite materials to time-dependent properties of its constituent materials (i.e., fiber and matrix). The Prony series combined with the multi-data fitting method was applied to inverse Laplace transform and to calculate the time dependent stiffness matrix effectively. Accelerated time-dependent deformation of two flywheel rim designs were studied for a period equivalent to 31 years and are compared with hoop reinforcement only composite. Damping of pure resin and T700/epoxy composite lamina and laminate in longitudinal and transverse directions were investigated experimentally and analytically. The effect of aging on damping was also studied by placing samples at 60°C in an oven for extended periods. Damping master curves versus frequency were constructed from individual curves at different temperatures based on the Arrhenius equation. The damping response of the composite lamina was used to predict the response of laminate composites. Analytical results give close numerical values to experimental results from damping of cantilever beam laminated composite samples.

  12. Accelerated characterization of graphite/epoxy composites

    NASA Technical Reports Server (NTRS)

    Griffith, W. I.; Morris, D. H.; Brinson, H. F.

    1980-01-01

    A method to predict the long term compliance of unidirectional off-axis laminates from short term laboratory tests is presented. The method uses an orthotropic transformation equation and the time-stress-temperature superposition principle. Short term tests are used to construct master curves for two off-axis unidirectional laminates with fiber angles of 10 and 90 degrees. Analytical predictions of long term compliance for 30 and 60 degrees laminates are made. Comparisons with experimental data are also given.

  13. Method and Excel VBA Algorithm for Modeling Master Recession Curve Using Trigonometry Approach.

    PubMed

    Posavec, Kristijan; Giacopetti, Marco; Materazzi, Marco; Birk, Steffen

    2017-11-01

    A new method was developed and implemented into an Excel Visual Basic for Applications (VBAs) algorithm utilizing trigonometry laws in an innovative way to overlap recession segments of time series and create master recession curves (MRCs). Based on a trigonometry approach, the algorithm horizontally translates succeeding recession segments of time series, placing their vertex, that is, the highest recorded value of each recession segment, directly onto the appropriate connection line defined by measurement points of a preceding recession segment. The new method and algorithm continues the development of methods and algorithms for the generation of MRC, where the first published method was based on a multiple linear/nonlinear regression model approach (Posavec et al. 2006). The newly developed trigonometry-based method was tested on real case study examples and compared with the previously published multiple linear/nonlinear regression model-based method. The results show that in some cases, that is, for some time series, the trigonometry-based method creates narrower overlaps of the recession segments, resulting in higher coefficients of determination R 2 , while in other cases the multiple linear/nonlinear regression model-based method remains superior. The Excel VBA algorithm for modeling MRC using the trigonometry approach is implemented into a spreadsheet tool (MRCTools v3.0 written by and available from Kristijan Posavec, Zagreb, Croatia) containing the previously published VBA algorithms for MRC generation and separation. All algorithms within the MRCTools v3.0 are open access and available free of charge, supporting the idea of running science on available, open, and free of charge software. © 2017, National Ground Water Association.

  14. Towards a universal master curve in magnetorheology

    NASA Astrophysics Data System (ADS)

    Ruiz-López, José Antonio; Hidalgo-Alvarez, Roque; de Vicente, Juan

    2017-05-01

    We demonstrate that inverse ferrofluids behave as model magnetorheological fluids. A universal master curve is proposed, using a reduced Mason number, under the frame of a structural viscosity model where the magnetic field strength dependence is solely contained in the Mason number and the particle concentration is solely contained in the critical Mason number (i.e. the yield stress). A linear dependence of the critical Mason number with the particle concentration is observed that is in good agreement with a mean (average) magnetization approximation, particle level dynamic simulations and micromechanical models available in the literature.

  15. Accelerated characterization of graphite/epoxy composites

    NASA Technical Reports Server (NTRS)

    Griffith, W. I.; Morris, D. H.; Brinson, H. F.

    1980-01-01

    A method to predict the long-term compliance of unidirectional off-axis laminates from short-term laboratory tests is presented. The method uses an orthotropic transformation equation and the time-stress-temperature superposition principle. Short-term tests are used to construct master curves for two off-axis unidirectional laminates with fiber angles of 10 deg and 90 deg. In addition, analytical predictions of long-term compliance for 30 deg and 60 deg laminates are made. Comparisons with experimental data are also given.

  16. Universal rescaling of flow curves for yield-stress fluids close to jamming

    NASA Astrophysics Data System (ADS)

    Dinkgreve, M.; Paredes, J.; Michels, M. A. J.; Bonn, D.

    2015-07-01

    The experimental flow curves of four different yield-stress fluids with different interparticle interactions are studied near the jamming concentration. By appropriate scaling with the distance to jamming all rheology data can be collapsed onto master curves below and above jamming that meet in the shear-thinning regime and satisfy the Herschel-Bulkley and Cross equations, respectively. In spite of differing interactions in the different systems, master curves characterized by universal scaling exponents are found for the four systems. A two-state microscopic theory of heterogeneous dynamics is presented to rationalize the observed transition from Herschel-Bulkley to Cross behavior and to connect the rheological exponents to microscopic exponents for the divergence of the length and time scales of the heterogeneous dynamics. The experimental data and the microscopic theory are compared with much of the available literature data for yield-stress systems.

  17. Application of fracture toughness scaling models to the ductile-to- brittle transition

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Link, R.E.; Joyce, J.A.

    1996-01-01

    An experimental investigation of fracture toughness in the ductile-brittle transition range was conducted. A large number of ASTM A533, Grade B steel, bend and tension specimens with varying crack lengths were tested throughout the transition region. Cleavage fracture toughness scaling models were utilized to correct the data for the loss of constraint in short crack specimens and tension geometries. The toughness scaling models were effective in reducing the scatter in the data, but tended to over-correct the results for the short crack bend specimens. A proposed ASTM Test Practice for Fracture Toughness in the Transition Range, which employs a mastermore » curve concept, was applied to the results. The proposed master curve over predicted the fracture toughness in the mid-transition and a modified master curve was developed that more accurately modeled the transition behavior of the material. Finally, the modified master curve and the fracture toughness scaling models were combined to predict the as-measured fracture toughness of the short crack bend and the tension specimens. It was shown that when the scaling models over correct the data for loss of constraint, they can also lead to non-conservative estimates of the increase in toughness for low constraint geometries.« less

  18. An Approximate Solution and Master Curves for Buckling of Symmetrically Laminated Composite Cylinders

    NASA Technical Reports Server (NTRS)

    Nemeth, Michael P.

    2013-01-01

    Nondimensional linear-bifurcation buckling equations for balanced, symmetrically laminated cylinders with negligible shell-wall anisotropies and subjected to uniform axial compression loads are presented. These equations are solved exactly for the practical case of simply supported ends. Nondimensional quantities are used to characterize the buckling behavior that consist of a stiffness-weighted length-to-radius parameter, a stiffness-weighted shell-thinness parameter, a shell-wall nonhomogeneity parameter, two orthotropy parameters, and a nondimensional buckling load. Ranges for the nondimensional parameters are established that encompass a wide range of laminated-wall constructions and numerous generic plots of nondimensional buckling load versus a stiffness-weighted length-to-radius ratio are presented for various combinations of the other parameters. These plots are expected to include many practical cases of interest to designers. Additionally, these plots show how the parameter values affect the distribution and size of the festoons forming each response curve and how they affect the attenuation of each response curve to the corresponding solution for an infinitely long cylinder. To aid in preliminary design studies, approximate formulas for the nondimensional buckling load are derived, and validated against the corresponding exact solution, that give the attenuated buckling response of an infinitely long cylinder in terms of the nondimensional parameters presented herein. A relatively small number of "master curves" are identified that give a nondimensional measure of the buckling load of an infinitely long cylinder as a function of the orthotropy and wall inhomogeneity parameters. These curves reduce greatly the complexity of the design-variable space as compared to representations that use dimensional quantities as design variables. As a result of their inherent simplicity, these master curves are anticipated to be useful in the ongoing development of buckling-design technology.

  19. MASTER OT J004207.99+405501.1/M31LRN 2015 luminous red nova in M31: discovery, light curve, hydrodynamics and evolution

    NASA Astrophysics Data System (ADS)

    Lipunov, V. M.; Blinnikov, S.; Gorbovskoy, E.; Tutukov, A.; Baklanov, P.; Krushinski, V.; Tiurina, N.; Balanutsa, P.; Kuznetsov, A.; Kornilov, V.; Gorbunov, I.; Shumkov, V.; Vladimirov, V.; Gress, O.; Budnev, N. M.; Ivanov, K.; Tlatov, A.; Gabovich, A.; Yurkov, V.; Sergienko, Yu.; Zalozhnykh, I.

    2017-09-01

    We report the discovery and multicolour (VRIW) photometry of the rare explosive star MASTER OT J004207.99+405501.1 - a luminous red nova - in the Andromeda galaxy M31N2015-01a. We use our original light curve acquired with identical MASTER Global Robotic Net telescopes in one photometric system: VRI during the first 30 d and W (unfiltered) during 70 d. Also, we added published multicolour photometry data to estimate the mass and energy of the ejected shell and we discuss the likely formation scenarios of outbursts of this type. We propose an interpretation of the explosion that is consistent with an evolutionary scenario where the merging of stellar components or the disruption of the common envelope of a close binary can explain some luminous red novae. Radiative hydrodynamic simulations of a luminous red nova were carried out in extended parameter space to fit its light curves. We find that the multicolour passband light curves of the luminous red nova are consistent with an initial common envelope radius of 10 R⊙, a merger mass of 3 M⊙ and an explosion energy of 3 × 1048 erg. As a result, the phenomenon of novae consists of two classes: classical nuclear novae and more rare events (red novae) connected with the loss of compact common envelopes.

  20. The intrinsic mechanical nonlinearity 3Q0(ω) of linear homopolymer melts

    NASA Astrophysics Data System (ADS)

    Cziep, Miriam Angela; Abbasi, Mahdi; Wilhelm, Manfred

    2017-05-01

    Medium amplitude oscillatory shear (MAOS) in combination with Fourier Transformation of the mechanical stress signal (FT rheology) was utilized to investigate the influence of molecular weight, molecular weight distribution and the monomer on the intrinsic nonlinearity 3Q0(ω). Nonlinear master curves of 3Q0(ω) have been created, applying the time-temperature superposition (TTS) principle. These master curves showed a characteristic shape with an increasing slope at small frequencies, a maximum 3Q0,max and a decreasing slope at high frequencies. 3Q0(De) master curves of monodisperse polymers were evaluated and quantified with the help of a semi-empiric equation, derived from predictions from the pom-pom and molecular stress function (MSF) models. This resulted in a monomer independent description of the nonlinear mechanical behavior of linear, monodisperse homopolymer melts, where 3Q0(ω,Z) is only a function of the frequency ω and the number of entanglements Z. For polydisperse samples, 3Q0(ω) showed a high sensitivity within the experimental window towards an increasing PDI. At small frequencies, the slope of 3Q0(ω) decreases until approximately zero as a plateau value is reached, starting at a PDI around 2 and higher.

  1. 3D shape recovery of a newborn skull using thin-plate splines.

    PubMed

    Lapeer, R J; Prager, R W

    2000-01-01

    The objective of this paper is to construct a mesh-model of a newborn skull for finite element analysis to study its deformation when subjected to the forces present during labour. The current state of medical imaging technology has reached a level which allows accurate visualisation and shape recovery of biological organs and body-parts. However, a sufficiently large set of medical images cannot always be obtained, often because of practical or ethical reasons, and the requirement to recover the shape of the biological object of interest has to be met by other means. Such is the case for a newborn skull. A method to recover the three-dimensional (3D) shape from (minimum) two orthogonal atlas images of the object of interest and a homologous object is described. This method is based on matching landmarks and curves on the orthogonal images of the object of interest with corresponding landmarks and curves on the homologous or 'master'-object which is fully defined in 3D space. On the basis of this set of corresponding landmarks, a thin-plate spline function can be derived to warp from the 'master'-object space to the 'slave'-object space. This method is applied to recover the 3D shape of a newborn skull. Images from orthogonal view-planes are obtained from an atlas. The homologous object is an adult skull, obtained from CT-images made available by the Visible Human Project. After shape recovery, a mesh-model of the newborn skull is generated.

  2. A Software Tool for the Rapid Analysis of the Sintering Behavior of Particulate Bodies

    DTIC Science & Technology

    2017-11-01

    bounded by a region that the user selects via cross hairs . Future plot analysis features, such as more complicated curve fitting and modeling functions...German RM. Grain growth behavior of tungsten heavy alloys based on the master sintering curve concept. Metallurgical and Materials Transactions A

  3. Corresponding states law for a generalized Lennard-Jones potential.

    PubMed

    Orea, P; Romero-Martínez, A; Basurto, E; Vargas, C A; Odriozola, G

    2015-07-14

    It was recently shown that vapor-liquid coexistence densities derived from Mie and Yukawa models collapse to define a single master curve when represented against the difference between the reduced second virial coefficient at the corresponding temperature and that at the critical point. In this work, we further test this proposal for another generalization of the Lennard-Jones pair potential. This is carried out for vapor-liquid coexistence densities, surface tension, and vapor pressure, along a temperature window set below the critical point. For this purpose, we perform molecular dynamics simulations by varying the potential softness parameter to produce from very short to intermediate attractive ranges. We observed all properties to collapse and yield master curves. Moreover, the vapor-liquid curve is found to share the exact shape of the Mie and attractive Yukawa. Furthermore, the surface tension and the logarithm of the vapor pressure are linear functions of this difference of reduced second virial coefficients.

  4. Viscoelastic characterization of thin-film polymers exposed to low Earth orbit

    NASA Technical Reports Server (NTRS)

    Letton, Alan; Farrow, Allan; Strganac, Thomas

    1993-01-01

    The materials made available through the Long Duration Exposure Facility (LDEF) satellite provide a set of specimens that can be well characterized and have a known exposure history with reference to atomic oxygen and ultraviolet radiation exposure. Mechanical characteristics measured from control samples and exposed samples provide a data base for predicting the behavior of polymers in low earth orbit. Samples of 1.0 mil thick low density polyethylene were exposed to the low earth orbit environment for a period of six years. These materials were not directly exposed to ram atomic oxygen and offer a unique opportunity for measuring the effect of atomic oxygen and UV radiation on mechanical properties with little concern to the effect of erosion. The viscoelastic characteristics of these materials were measured and compared to the viscoelastic characteristics of control samples. To aid in differentiating the effects of changes in crystallinity resulting from thermal cycling, from the effects of changes in chemical structure resulting from atomic oxygen/UV attack to the polymer, a second set of control specimens, annealed to increase crystallinity, were measured as well. The resulting characterization of these materials will offer insight into the impact of atomic oxygen/UV on the mechanical properties of polymeric materials. The viscoelastic properties measured for the control, annealed, and exposed specimens were the storage and loss modulus as a function of frequency and temperature. From these datum is calculated the viscoelastic master curve derived using the principle of time/temperature superposition. Using the master curve, the relaxation modulus is calculated using the method of Ninomiya and Ferry. The viscoelastic master curve and the stress relaxation modulus provide a direct measure of the changes in the chemical or morphological structure. In addition, the effect of these changes on long-term and short-term mechanical properties is known directly. It should be noted that the dependence on directionality for the polymer films was considered since these films were manufactured by a blown-film process.

  5. Validation of Modifications to the ANSR for Listeria Method for Improved Internal Positive Control Performance.

    PubMed

    Alles, Susan; Meister, Evan; Hosking, Edan; Tovar, Eric; Shaulis, Rebecca; Schonfeld, Mark; Zhang, Lei; Li, Lin; Biswas, Preetha; Mozola, Mark; Donofrio, Robert; Chen, Yi

    2018-03-01

    A study was conducted to validate a minor reagent formulation change to the ANSR for Listeria method, Performance Tested MethodSM 101202. This change involves increasing the master mix volume prelyophilization by 40% and addition of salmon sperm DNA (nontarget DNA) to the master mix. These changes improve the robustness of the internal positive control response and reduce the possibility of obtaining invalid results due to weak-positive control curves. When three foods (hot dogs, Mexican-style cheese, and cantaloupe) and sponge samples taken from a stainless steel surface were tested, no significant differences in performance between the ANSR and U.S. Food and Drug Administration Bacteriological Analytical Manual or U.S. Department of Agriculture-Food Safety and Inspection Service Microbiology Laboratory Guidebook reference culture procedures were observed for any of the matrixes as determined by probability of detection analysis. Inclusivity and exclusivity testing yielded 100% expected results for target and nontarget bacteria. Accelerated stability testing was carried out over a 7 week period and showed no decrease in assay performance over time.

  6. Volcanic facies architecture of an intra-arc strike-slip basin, Santa Rita Mountains, Southern Arizona

    NASA Astrophysics Data System (ADS)

    Busby, Cathy J.; Bassett, Kari N.

    2007-09-01

    The three-dimensional arrangement of volcanic deposits in strike-slip basins is not only the product of volcanic processes, but also of tectonic processes. We use a strike-slip basin within the Jurassic arc of southern Arizona (Santa Rita Glance Conglomerate) to construct a facies model for a strike-slip basin dominated by volcanism. This model is applicable to releasing-bend strike-slip basins, bounded on one side by a curved and dipping strike-slip fault, and on the other by curved normal faults. Numerous, very deep unconformities are formed during localized uplift in the basin as it passes through smaller restraining bends along the strike-slip fault. In our facies model, the basin fill thins and volcanism decreases markedly away from the master strike-slip fault (“deep” end), where subsidence is greatest, toward the basin-bounding normal faults (“shallow” end). Talus cone-alluvial fan deposits are largely restricted to the master fault-proximal (deep) end of the basin. Volcanic centers are sited along the master fault and along splays of it within the master fault-proximal (deep) end of the basin. To a lesser degree, volcanic centers also form along the curved faults that form structural highs between sub-basins and those that bound the distal ends of the basin. Abundant volcanism along the master fault and its splays kept the deep (master fault-proximal) end of the basin overfilled, so that it could not provide accommodation for reworked tuffs and extrabasinally-sourced ignimbrites that dominate the shallow (underfilled) end of the basin. This pattern of basin fill contrasts markedly with that of nonvolcanic strike-slip basins on transform margins, where clastic sedimentation commonly cannot keep pace with subsidence in the master fault-proximal end. Volcanic and subvolcanic rocks in the strike-slip basin largely record polygenetic (explosive and effusive) small-volume eruptions from many vents in the complexly faulted basin, referred to here as multi-vent complexes. Multi-vent complexes like these reflect proximity to a continuously active fault zone, where numerous strands of the fault frequently plumb small batches of magma to the surface. Releasing-bend extension promotes small, multivent styles of volcanism in preference to caldera collapse, which is more likely to form at releasing step-overs along a strike-slip fault.

  7. CEC-normalized clay-water sorption isotherm

    NASA Astrophysics Data System (ADS)

    Woodruff, W. F.; Revil, A.

    2011-11-01

    A normalized clay-water isotherm model based on BET theory and describing the sorption and desorption of the bound water in clays, sand-clay mixtures, and shales is presented. Clay-water sorption isotherms (sorption and desorption) of clayey materials are normalized by their cation exchange capacity (CEC) accounting for a correction factor depending on the type of counterion sorbed on the mineral surface in the so-called Stern layer. With such normalizations, all the data collapse into two master curves, one for sorption and one for desorption, independent of the clay mineralogy, crystallographic considerations, and bound cation type; therefore, neglecting the true heterogeneity of water sorption/desorption in smectite. The two master curves show the general hysteretic behavior of the capillary pressure curve at low relative humidity (below 70%). The model is validated against several data sets obtained from the literature comprising a broad range of clay types and clay mineralogies. The CEC values, derived by inverting the sorption/adsorption curves using a Markov chain Monte Carlo approach, are consistent with the CEC associated with the clay mineralogy.

  8. GENIE - Generation of computational geometry-grids for internal-external flow configurations

    NASA Technical Reports Server (NTRS)

    Soni, B. K.

    1988-01-01

    Progress realized in the development of a master geometry-grid generation code GENIE is presented. The grid refinement process is enhanced by developing strategies to utilize bezier curves/surfaces and splines along with weighted transfinite interpolation technique and by formulating new forcing function for the elliptic solver based on the minimization of a non-orthogonality functional. A two step grid adaptation procedure is developed by optimally blending adaptive weightings with weighted transfinite interpolation technique. Examples of 2D-3D grids are provided to illustrate the success of these methods.

  9. Study of diffusion coefficient of anhydrous trehalose glasses by using PFG-NMR spectroscopy

    NASA Astrophysics Data System (ADS)

    Kwon, Hyun-Joung; Takekawa, Reiji; Kawamura, Junichi; Tokuyama, Michio

    2013-02-01

    We investigated the temperature dependent long time self-diffusion coefficient of the anhydrous trehalose supercooled liquids by using pulsed field gradient nuclear magnetic resonance (PFG-NMR) spectroscopy. At the same temperature ranges, the diffusion coefficient convoluted from the α-relaxation time as Einstein-Smoluchowski relaxation, measured by using the dielectric loss spectroscopy are well overlapped with diffusion coefficients within experimental error. The temperature dependent diffusion coefficients obtained from different methods are normalized by fictive temperature and well satisfied the single master curve, proposed by Tokuyama.

  10. Extension of the master sintering curve for constant heating rate modeling

    NASA Astrophysics Data System (ADS)

    McCoy, Tammy Michelle

    The purpose of this work is to extend the functionality of the Master Sintering Curve (MSC) such that it can be used as a practical tool for predicting sintering schemes that combine both a constant heating rate and an isothermal hold. Rather than just being able to predict a final density for the object of interest, the extension to the MSC will actually be able to model a sintering run from start to finish. Because the Johnson model does not incorporate this capability, the work presented is an extension of what has already been shown in literature to be a valuable resource in many sintering situations. A predicted sintering curve that incorporates a combination of constant heating rate and an isothermal hold is more indicative of what is found in real-life sintering operations. This research offers the possibility of predicting the sintering schedule for a material, thereby having advanced information about the extent of sintering, the time schedule for sintering, and the sintering temperature with a high degree of accuracy and repeatability. The research conducted in this thesis focuses on the development of a working model for predicting the sintering schedules of several stabilized zirconia powders having the compositions YSZ (HSY8), 10Sc1CeSZ, 10Sc1YSZ, and 11ScSZ1A. The compositions of the four powders are first verified using x-ray diffraction (XRD) and the particle size and surface area are verified using a particle size analyzer and BET analysis, respectively. The sintering studies were conducted on powder compacts using a double pushrod dilatometer. Density measurements are obtained both geometrically and using the Archimedes method. Each of the four powders is pressed into ¼" diameter pellets using a manual press with no additives, such as a binder or lubricant. Using a double push-rod dilatometer, shrinkage data for the pellets is obtained over several different heating rates. The shrinkage data is then converted to reflect the change in relative density of the pellets based on the green density and the theoretical density of each of the compositions. The Master Sintering Curve (MSC) model is then utilized to generate data that can be utilized to predict the final density of the respective powder over a range of heating rates. The Elton Master Sintering Curve Extension (EMSCE) is developed to extend the functionality of the MSC tool. The parameters generated from the original MSC are used in tandem with the solution to the closed integral, theta ≡ 1cTo T1Texp -QRT dT, over a set range of temperatures. The EMSCE is used to generate a set of sintering curves having both constant heating rate and isothermal hold portions. The EMSCE extends the usefulness of the MSC by allowing this generation of a complete sintering schedule rather than just being able to predict the final relative density of a given material. The EMSCE is verified by generating a set of curves having both constant heating rate and an isothermal hold for the heat-treatment. The modeled curves are verified experimentally and a comparison of the model and experimental results are given for a selected composition. Porosity within the final product can hinder the product from sintering to full density. It is shown that some of the compositions studied did not sinter to full density because of the presence of large porosity that could not be eliminated in a reasonable amount of time. A statistical analysis of the volume fraction of porosity is completed to show the significance of the presence in the final product. The reason this is relevant to the MSC is that the model does not take into account the presence of porosity and assumes that the samples sinter to full density. When this does not happen, the model actually under-predicts the final density of the material.

  11. Application of the compensated Arrhenius formalism to explain the dielectric constant dependence of rates for Menschutkin reactions.

    PubMed

    Petrowsky, Matt; Glatzhofer, Daniel T; Frech, Roger

    2013-11-21

    The dependence of the reaction rate on solvent dielectric constant is examined for the reaction of trihexylamine with 1-bromohexane in a series of 2-ketones over the temperature range 25-80 °C. The rate constant data are analyzed using the compensated Arrhenius formalism (CAF), where the rate constant assumes an Arrhenius-like equation that also contains a dielectric constant dependence in the exponential prefactor. The CAF activation energies are substantially higher than those obtained using the simple Arrhenius equation. A master curve of the data is observed by plotting the prefactors against the solvent dielectric constant. The master curve shows that the reaction rate has a weak dependence on dielectric constant for values approximately less than 10 and increases more rapidly for dielectric constant values greater than 10.

  12. Creep rupture behavior of unidirectional advanced composites

    NASA Technical Reports Server (NTRS)

    Yeow, Y. T.

    1980-01-01

    A 'material modeling' methodology for predicting the creep rupture behavior of unidirectional advanced composites is proposed. In this approach the parameters (obtained from short-term tests) required to make the predictions are the three principal creep compliance master curves and their corresponding quasi-static strengths tested at room temperature (22 C). Using these parameters in conjunction with a failure criterion, creep rupture envelopes can be generated for any combination of in-plane loading conditions and ambient temperature. The analysis was validated experimentally for one composite system, the T300/934 graphite-epoxy system. This was done by performing short-term creep tests (to generate the principal creep compliance master curves with the time-temperature superposition principle) and relatively long-term creep rupture tensile tests of off-axis specimens at 180 C. Good to reasonable agreement between experimental and analytical results is observed.

  13. Nondimensional scaling of magnetorheological rotary shear mode devices using the Mason number

    NASA Astrophysics Data System (ADS)

    Becnel, Andrew C.; Sherman, Stephen; Hu, Wei; Wereley, Norman M.

    2015-04-01

    Magnetorheological fluids (MRFs) exhibit rapidly adjustable viscosity in the presence of a magnetic field, and are increasingly used in adaptive shock absorbers for high speed impacts, corresponding to high fluid shear rates. However, the MRF properties are typically measured at very low (γ ˙<1000 s-1) shear rates due to limited commercial rheometer capabilities. A custom high shear rate (γ ˙>10,000 s-1) Searle cell magnetorheometer, along with a full scale rotary-vane magnetorheological energy absorber (γ ˙>25,000 s-1) are employed to analyze MRF property scaling across shear rates using a nondimensional Mason number to generate an MRF master curve. Incorporating a Reynolds temperature correction factor, data from both experiments is shown to collapse to a single master curve, supporting the use of Mason number to correlate low- and high-shear rate characterization data.

  14. Determination of dynamic modulus master curves for Oklahoma HMA mixtures.

    DOT National Transportation Integrated Search

    2007-12-01

    The Mechanistic-Empirical Pavement Design Guide (M-EPDG) uses a hierarchical approach with three : levels of material characterization for asphalt materials. The first level provides the highest design : reliability and each succeeding level is a dro...

  15. Development of asphalt dynamic modulus master curve using falling weight deflectometer measurements.

    DOT National Transportation Integrated Search

    2014-06-01

    The asphalt concrete (AC) dynamic modulus (|E*|) is a key design parameter in mechanistic-based pavement design : methodologies such as the American Association of State Highway and Transportation Officials (AASHTO) MEPDG/Pavement-ME Design. The obje...

  16. Preparation of silicon target material by adding Al-B master alloy in directional solidification

    NASA Astrophysics Data System (ADS)

    Li, Pengting; Wang, Kai; Ren, Shiqiang; Jiang, Dachuan; Tan, Yi

    2017-03-01

    The silicon target material was prepared by adding Al-6B master alloy in directional solidification. The microstructure was characterized and the resistivity was studied in this work. The results showed that the purity of the silicon target material was more than 99.999% (5N). The resistivity was ranges from 0.002 to 0.030 Ω·cm along the ingot height. It was revealed that the particles of AlB2 in Al-6B master alloy would react spontaneously and generate clusters of [B] and [Al] in molten silicon at 1723 K. After directional solidification, the content of B and Al were increasing gradually with the increase of solidified fraction. The measured values of B were in good agreement with the curve of the Scheil equation below 80% of the ingot height. The mean concentration of B was about 17.20 ppmw and the mean concentration of Al was about 8.07 ppmw after directional solidification. The measured values of Al were fitting well with the curve of values which the effective segregation coefficient was 0.00378. It was observed that B co-doped Al in directional solidification polysilicon could regulate resistivity mutually. This work provides the theoretical basis and technical support for industrial production of the silicon target material.

  17. A novel statistical approach for identification of the master regulator transcription factor.

    PubMed

    Sikdar, Sinjini; Datta, Susmita

    2017-02-02

    Transcription factors are known to play key roles in carcinogenesis and therefore, are gaining popularity as potential therapeutic targets in drug development. A 'master regulator' transcription factor often appears to control most of the regulatory activities of the other transcription factors and the associated genes. This 'master regulator' transcription factor is at the top of the hierarchy of the transcriptomic regulation. Therefore, it is important to identify and target the master regulator transcription factor for proper understanding of the associated disease process and identifying the best therapeutic option. We present a novel two-step computational approach for identification of master regulator transcription factor in a genome. At the first step of our method we test whether there exists any master regulator transcription factor in the system. We evaluate the concordance of two ranked lists of transcription factors using a statistical measure. In case the concordance measure is statistically significant, we conclude that there is a master regulator. At the second step, our method identifies the master regulator transcription factor, if there exists one. In the simulation scenario, our method performs reasonably well in validating the existence of a master regulator when the number of subjects in each treatment group is reasonably large. In application to two real datasets, our method ensures the existence of master regulators and identifies biologically meaningful master regulators. An R code for implementing our method in a sample test data can be found in http://www.somnathdatta.org/software . We have developed a screening method of identifying the 'master regulator' transcription factor just using only the gene expression data. Understanding the regulatory structure and finding the master regulator help narrowing the search space for identifying biomarkers for complex diseases such as cancer. In addition to identifying the master regulator our method provides an overview of the regulatory structure of the transcription factors which control the global gene expression profiles and consequently the cell functioning.

  18. Prediction of Long-Term Strength of Thermoplastic Composites Using Time-Temperature Superposition. Degree awarded by Texas A&M Univ., May 1998

    NASA Technical Reports Server (NTRS)

    Reeder, James R.

    2002-01-01

    Accelerated tests for composite failure were investigated. Constant ramp transverse strength tests on thermoplastic composite specimens were conducted at four temperatures from 300 F to 450 F and five duration times from 0.5 sec to 24 hrs. Up to 400 F, the time-temperature-superposition method produces a master curve allowing strength at longer times to be estimated from strength tests conducted over shorter times but at higher temperatures. The shift factors derived from compliance tests applied well to the strength data. To explain why strength behaved similar to compliance, a viscoelastic fracture model was investigated based on the hypothesis that the work of fracture for crack initiation at some critical flaw remains constant with time and temperature. The model, which used compliance as input, was found to fit the strength data only if the critical fracture energy was allowed to vary with stress rate. Fracture tests using double cantilever beam specimens were conducted from 300 F to 450 F over time scales similar to the strength study. The toughness data showed a significant change with loading rate, less variation with temperature, did not form a master curve, and could not be correlated with the fracture model. Since the fracture model did not fit the fracture data, an alternative explanation based on the dilatational strain energy density was proposed. However the usefulness of this model is severely limited because it relies on a critical parameter which varies with loading rate.

  19. Sintering Behavior of Nanocrystalline Silicon Carbide Using a Plasma Pressure Compaction System: Master Sintering Curve Analysis

    NASA Astrophysics Data System (ADS)

    Bothara, Manish G.; Atre, Sundar V.; Park, Seong-Jin; German, Randall M.; Sudarshan, T. S.; Radhakrishnan, R.

    2010-12-01

    Nanostructured ceramics offer significant improvements in properties over corresponding materials with larger grain sizes on the order of tens to hundreds of micrometers. Silicon carbide (SiC) samples with grain sizes on the order of 100 nm can result in improved strength, chemical resistance, thermal stability, and tailored electrical resistivity. In this study, nanocrystalline SiC was processed in a plasma pressure compaction (P2C) system at a temperature of 1973 K (1700 °C) that was much lower than the temperatures reported for other sintering techniques. Microstructure of the resulting samples was studied and the hardness and the fracture toughness were measured. The grain sizes were on the order of 700 nm, the hardness between 22 and 24 GPa, and the toughness between 5 and 6.5 MPa·m1/2. The master sintering curve (MSC) analysis was used to model the densification behavior of SiC powder sintered by the P2C method. The apparent activation energies for three different pressures of 10, 30, and 50 MPa were obtained to be 1666, 1034, and 1162 kJ/mol, respectively. Although densification occurs via diffusion, the activation energies were higher than those associated with self-diffusion in SiC (between 570 and 920 kJ/mol). A validation study of the MSC was also conducted and the variation in observed density from the density predicted by the MSC was found to range from 1 to 10 pct.

  20. An Innovative Concept for Testing Rutting Susceptibility of Asphalt Mixture

    NASA Astrophysics Data System (ADS)

    Mohseni, Alaeddin; Azari, Haleh

    Currently, flow number (FN) is being used for measuring permanent deformation resistance of asphalt mixtures. The provisional AASHTO TP 79-10 test method specifies the requirements of the FN test; however, there are undefined levels of test variables, such as temperature, axial stress, and confinement. Therefore, agreeable FN criteria that can reliably discriminate between various mixtures have not been established yet. As the asphalt industry continues to develop more sophisticated mixtures (Warm Mix, RAP and RAS), the FN value has failed to capture the true complexity of the asphalt mixtures. These shortcomings and the unpredictable testing time of the FN test have affected its usefulness for evaluating high temperature performance of asphalt mixtures. A new test procedure for evaluation of rutting susceptibility of asphalt mixtures is being proposed. The new procedure is conducted at one temperature and multiple stresses on the same replicate in three increments of 500 cycles, which only takes 33 minutes to complete. The property of the test is the permanent strain due to the last cycle of each test increment (Minimum Strain Rate, or MSR). A master curve is developed by plotting the MSR values versus parameter TP, which is a product of Temperature and Pressure. The MSR master curve represents the unit rutting damage (rut per axle) of asphalt mixtures at any stress and temperature and can be used in laboratory for material characterization, mix design verification, ranking of the mixtures, or for pavement design applications to predict rut depth for project climate and design traffic.

  1. Modelling of Asphalt Concrete Stiffness in the Linear Viscoelastic Region

    NASA Astrophysics Data System (ADS)

    Mazurek, Grzegorz; Iwański, Marek

    2017-10-01

    Stiffness modulus is a fundamental parameter used in the modelling of the viscoelastic behaviour of bituminous mixtures. On the basis of the master curve in the linear viscoelasticity range, the mechanical properties of asphalt concrete at different loading times and temperatures can be predicted. This paper discusses the construction of master curves under rheological mathematical models i.e. the sigmoidal function model (MEPDG), the fractional model, and Bahia and co-workers’ model in comparison to the results from mechanistic rheological models i.e. the generalized Huet-Sayegh model, the generalized Maxwell model and the Burgers model. For the purposes of this analysis, the reference asphalt concrete mix (denoted as AC16W) intended for the binder coarse layer and for traffic category KR3 (5×105

  2. Tensile Properties of 17-7 PH and 12 MoV Stainless-Steel Sheet under Rapid-Heating and Constant-Temperature Conditions

    NASA Technical Reports Server (NTRS)

    Manning, Charles R., Jr.; Price, Howard L.

    1961-01-01

    Results are presented of rapid-heating tests of 17-7 PH and 12 MoV stainless-steel sheet heated to failure at temperature rates from about 1 F to 170 F per second under constant-load conditions. Yield and rupture strengths obtained from rapid-heating tests are compared with yield and tensile strengths obtained from short-time elevated-temperature tensile tests (30-minute exposure). A rate-temperature parameter was used to construct master curves from which yield and rupture stresses or temperatures can be predicted. A method for measuring strain by optical means is described.

  3. 38 CFR 39.32 - Plan preparation.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... a previously approved project and there have been no changes. Relevant information may then be shown... having other change or direction between corners) shall be referenced with curve data (including... indicated. The master plan shall analyze all factors affecting the design, including climate, soil...

  4. Econophysics: Master curve for price-impact function

    NASA Astrophysics Data System (ADS)

    Lillo, Fabrizio; Farmer, J. Doyne; Mantegna, Rosario N.

    2003-01-01

    The price reaction to a single transaction depends on transaction volume, the identity of the stock, and possibly many other factors. Here we show that, by taking into account the differences in liquidity for stocks of different size classes of market capitalization, we can rescale both the average price shift and the transaction volume to obtain a uniform price-impact curve for all size classes of firm for four different years (1995-98). This single-curve collapse of the price-impact function suggests that fluctuations from the supply-and-demand equilibrium for many financial assets, differing in economic sectors of activity and market capitalization, are governed by the same statistical rule.

  5. The learning curve of laparoscopic holecystectomy in general surgery resident training: old age of the patient may be a risk factor?

    PubMed

    Ferrarese, Alessia; Gentile, Valentina; Bindi, Marco; Rivelli, Matteo; Cumbo, Jacopo; Solej, Mario; Enrico, Stefano; Martino, Valter

    2016-01-01

    A well-designed learning curve is essential for the acquisition of laparoscopic skills: but, are there risk factors that can derail the surgical method? From a review of the current literature on the learning curve in laparoscopic surgery, we identified learning curve components in video laparoscopic cholecystectomy; we suggest a learning curve model that can be applied to assess the progress of general surgical residents as they learn and master the stages of video laparoscopic cholecystectomy regardless of type of patient. Electronic databases were interrogated to better define the terms "surgeon", "specialized surgeon", and "specialist surgeon"; we surveyed the literature on surgical residency programs outside Italy to identify learning curve components, influential factors, the importance of tutoring, and the role of reference centers in residency education in surgery. From the definition of acceptable error, self-efficacy, and error classification, we devised a learning curve model that may be applied to training surgical residents in video laparoscopic cholecystectomy. Based on the criteria culled from the literature, the three surgeon categories (general, specialized, and specialist) are distinguished by years of experience, case volume, and error rate; the patients were distinguished for years and characteristics. The training model was constructed as a series of key learning steps in video laparoscopic cholecystectomy. Potential errors were identified and the difficulty of each step was graded using operation-specific characteristics. On completion of each procedure, error checklist scores on procedure-specific performance are tallied to track the learning curve and obtain performance indices of measurement that chart the trainee's progress. The concept of the learning curve in general surgery is disputed. The use of learning steps may enable the resident surgical trainee to acquire video laparoscopic cholecystectomy skills proportional to the instructor's ability, the trainee's own skills, and the safety of the surgical environment. There were no patient characteristics that can derail the methods. With this training scheme, resident trainees may be provided the opportunity to develop their intrinsic capabilities without the loss of basic technical skills.

  6. A critical evaluation of theories for predicting microcracking in composite laminates

    NASA Technical Reports Server (NTRS)

    Nairn, John A.; Hu, Shoufeng; Bark, Jong S.

    1993-01-01

    We present experimental results on 21 different layups of Hercules AS4 carbon fiber/3501-6 epoxy laminates. All laminates had 90 deg plies; some had them in the middle, while some had them on a free surface. During tensile loading, the first form of damage in all laminates was microcracking of the 90 deg plies. For each laminate, we recorded both the crack density and the complete distribution of crack spacings as a function of the applied load. By rearranging various microcracking theories, we developed a master-curve approach that permitted plotting the results from all laminates on a single plot. By comparing master-curve plots for different theories, it was possible to critically evaluate the quality of those theories. We found that a critical-energy-release-rate criterion calculated using a 2D variational stress analysis gave the best results. All microcracking theories based on a strength-failure criteria gave poor results. All microcracking theories using 1D stress analyses, regardless of the failure criterion, also gave poor results.

  7. A fractional model with parallel fractional Maxwell elements for amorphous thermoplastics

    NASA Astrophysics Data System (ADS)

    Lei, Dong; Liang, Yingjie; Xiao, Rui

    2018-01-01

    We develop a fractional model to describe the thermomechanical behavior of amorphous thermoplastics. The fractional model is composed of two parallel fractional Maxwell elements. The first fractional Maxwell model is used to describe the glass transition, while the second component is aimed at describing the viscous flow. We further derive the analytical solutions for the stress relaxation modulus and complex modulus through Laplace transform. We then demonstrate the model is able to describe the master curves of the stress relaxation modulus, storage modulus and loss modulus, which all show two distinct transition regions. The obtained parameters show that the modulus of the two fractional Maxwell elements differs in 2-3 orders of magnitude, while the relaxation time differs in 7-9 orders of magnitude. Finally, we apply the model to describe the stress response of constant strain rate tests. The model, together with the parameters obtained from fitting the master curve of stress relaxation modulus, can accurately predict the temperature and strain rate dependent stress response.

  8. Linear and nonlinear mechanical properties of a series of epoxy resins

    NASA Technical Reports Server (NTRS)

    Curliss, D. B.; Caruthers, J. M.

    1987-01-01

    The linear viscoelastic properties have been measured for a series of bisphenol-A-based epoxy resins cured with the diamine DDS. The linear viscoelastic master curves were constructed via time-temperature superposition of frequency dependent G-prime and G-double-prime isotherms. The G-double-prime master curves exhibited two sub-Tg transitions. Superposition of isotherms in the glass-to-rubber transition (i.e., alpha) and the beta transition at -60 C was achieved by simple horizontal shifts in the log frequency axis; however, in the region between alpha and beta, superposition could not be effected by simple horizontal shifts along the log frequency axis. The different temperature dependency of the alpha and beta relaxation mechanisms causes a complex response of G-double-prime in the so called alpha-prime region. A novel numerical procedure has been developed to extract the complete relaxation spectra and its temperature dependence from the G-prime and G-double-prime isothermal data in the alpha-prime region.

  9. Secure SCADA communication by using a modified key management scheme.

    PubMed

    Rezai, Abdalhossein; Keshavarzi, Parviz; Moravej, Zahra

    2013-07-01

    This paper presents and evaluates a new cryptographic key management scheme which increases the efficiency and security of the Supervisory Control And Data Acquisition (SCADA) communication. In the proposed key management scheme, two key update phases are used: session key update and master key update. In the session key update phase, session keys are generated in the master station. In the master key update phase, the Elliptic Curve Diffie-Hellman (ECDH) protocol is used. The Poisson process is also used to model the Security Index (SI) and Quality of Service (QoS). Our analysis shows that the proposed key management not only supports the required speed in the MODBUS implementation but also has several advantages compared to other key management schemes for secure communication in SCADA networks. Copyright © 2013 ISA. Published by Elsevier Ltd. All rights reserved.

  10. Numerical simulation of photocurrent generation in bilayer organic solar cells: Comparison of master equation and kinetic Monte Carlo approaches

    NASA Astrophysics Data System (ADS)

    Casalegno, Mosè; Bernardi, Andrea; Raos, Guido

    2013-07-01

    Numerical approaches can provide useful information about the microscopic processes underlying photocurrent generation in organic solar cells (OSCs). Among them, the Kinetic Monte Carlo (KMC) method is conceptually the simplest, but computationally the most intensive. A less demanding alternative is potentially represented by so-called Master Equation (ME) approaches, where the equations describing particle dynamics rely on the mean-field approximation and their solution is attained numerically, rather than stochastically. The description of charge separation dynamics, the treatment of electrostatic interactions and numerical stability are some of the key issues which have prevented the application of these methods to OSC modelling, despite of their successes in the study of charge transport in disordered system. Here we describe a three-dimensional ME approach to photocurrent generation in OSCs which attempts to deal with these issues. The reliability of the proposed method is tested against reference KMC simulations on bilayer heterojunction solar cells. Comparison of the current-voltage curves shows that the model well approximates the exact result for most devices. The largest deviations in current densities are mainly due to the adoption of the mean-field approximation for electrostatic interactions. The presence of deep traps, in devices characterized by strong energy disorder, may also affect result quality. Comparison of the simulation times reveals that the ME algorithm runs, on the average, one order of magnitude faster than KMC.

  11. Experimental Observation of Two Features Unexpected from the Classical Theories of Rubber Elasticity

    NASA Astrophysics Data System (ADS)

    Nishi, Kengo; Fujii, Kenta; Chung, Ung-il; Shibayama, Mitsuhiro; Sakai, Takamasa

    2017-12-01

    Although the elastic modulus of a Gaussian chain network is thought to be successfully described by classical theories of rubber elasticity, such as the affine and phantom models, verification experiments are largely lacking owing to difficulties in precisely controlling of the network structure. We prepared well-defined model polymer networks experimentally, and measured the elastic modulus G for a broad range of polymer concentrations and connectivity probabilities, p . In our experiment, we observed two features that were distinct from those predicted by classical theories. First, we observed the critical behavior G ˜|p -pc|1.95 near the sol-gel transition. This scaling law is different from the prediction of classical theories, but can be explained by analogy between the electric conductivity of resistor networks and the elasticity of polymer networks. Here, pc is the sol-gel transition point. Furthermore, we found that the experimental G -p relations in the region above C* did not follow the affine or phantom theories. Instead, all the G /G0-p curves fell onto a single master curve when G was normalized by the elastic modulus at p =1 , G0. We show that the effective medium approximation for Gaussian chain networks explains this master curve.

  12. A computer program for predicting recharge with a master recession curve

    USGS Publications Warehouse

    Heppner, Christopher S.; Nimmo, John R.

    2005-01-01

    Water-table fluctuations occur in unconfined aquifers owing to ground-water recharge following precipitation and infiltration, and ground-water discharge to streams between storm events. Ground-water recharge can be estimated from well hydrograph data using the water-table fluctuation (WTF) principle, which states that recharge is equal to the product of the water-table rise and the specific yield of the subsurface porous medium. The water-table rise, however, must be expressed relative to the water level that would have occurred in the absence of recharge. This requires a means for estimating the recession pattern of the water-table at the site. For a given site there is often a characteristic relation between the water-table elevation and the water-table decline rate following a recharge event. A computer program was written which extracts the relation between decline rate and water-table elevation from well hydrograph data and uses it to construct a master recession curve (MRC). The MRC is a characteristic water-table recession hydrograph, representing the average behavior for a declining water-table at that site. The program then calculates recharge using the WTF method by comparing the measured well hydrograph with the hydrograph predicted by the MRC and multiplying the difference at each time step by the specific yield. This approach can be used to estimate recharge in a continuous fashion from long-term well records. Presented here is a description of the code including the WTF theory and instructions for running it to estimate recharge with continuous well hydrograph data.

  13. Master curve captures the effect of domain morphology on ethanol pervaporation through block copolymer membranes

    USDA-ARS?s Scientific Manuscript database

    We report on the effect of changing nanoscale morphology on pervaporation of ethanol/water mixtures through block copolymer membranes. Experiments were conducted using polystyrene-b-polybutadiene-b-polystyrene (SBS) copolymers with polybutadiene (PB) as the ethanol transporting block, using an 8 wt%...

  14. Mentorship, learning curves, and balance.

    PubMed

    Cohen, Meryl S; Jacobs, Jeffrey P; Quintessenza, James A; Chai, Paul J; Lindberg, Harald L; Dickey, Jamie; Ungerleider, Ross M

    2007-09-01

    Professionals working in the arena of health care face a variety of challenges as their careers evolve and develop. In this review, we analyze the role of mentorship, learning curves, and balance in overcoming challenges that all such professionals are likely to encounter. These challenges can exist both in professional and personal life. As any professional involved in health care matures, complex professional skills must be mastered, and new professional skills must be acquired. These skills are both technical and judgmental. In most circumstances, these skills must be learned. In 2007, despite the continued need for obtaining new knowledge and learning new skills, the professional and public tolerance for a "learning curve" is much less than in previous decades. Mentorship is the key to success in these endeavours. The success of mentorship is two-sided, with responsibilities for both the mentor and the mentee. The benefits of this relationship must be bidirectional. It is the responsibility of both the student and the mentor to assure this bidirectional exchange of benefit. This relationship requires time, patience, dedication, and to some degree selflessness. This mentorship will ultimately be the best tool for mastering complex professional skills and maturing through various learning curves. Professional mentorship also requires that mentors identify and explicitly teach their mentees the relational skills and abilities inherent in learning the management of the triad of self, relationships with others, and professional responsibilities.Up to two decades ago, a learning curve was tolerated, and even expected, while professionals involved in healthcare developed the techniques that allowed for the treatment of previously untreatable diseases. Outcomes have now improved to the point that this type of learning curve is no longer acceptable to the public. Still, professionals must learn to perform and develop independence and confidence. The responsibility to meet this challenge without a painful learning curve belongs to both the younger professionals, who must progress through the learning curve, and the more mature professionals who must create an appropriate environment for learning. In addition to mentorship, the detailed tracking of outcomes is an essential tool for mastering any learning curve. It is crucial to utilize a detailed database to track outcomes, to learn, and to protect both yourself and your patients. It is our professional responsibility to engage in self-evaluation, in part employing voluntary sharing of data. For cardiac surgical subspecialties, the databases now existing for The European Association for CardioThoracic Surgery and The Society of Thoracic Surgeons represent the ideal tool for monitoring outcomes. Evolving initiatives in the fields of paediatric cardiology, paediatric critical care, and paediatric cardiac anaesthesia will play similar roles.A variety of professional and personal challenges must be met by all those working in health care. The acquisition of learned skills, and the use of special tools, will facilitate the process of conquering these challenges. Choosing appropriate role models and mentors can help progression through any learning curve in a controlled and protected fashion. Professional and personal satisfaction are both necessities. Finding the satisfactory balance between work and home life is difficult, but possible with the right tools, organization skills, and support system at work and at home. The concepts of mentorship, learning curves and balance cannot be underappreciated.

  15. Magnetic printing characteristics using master disk with perpendicular magnetic anisotropy

    NASA Astrophysics Data System (ADS)

    Fujiwara, Naoto; Nishida, Yoichi; Ishioka, Toshihide; Sugita, Ryuji; Yasunaga, Tadashi

    With the increase in recording density and capacity of hard-disk drives (HDD), high speed, high precision and low cost servo writing method has become an issue in HDD industry. The magnetic printing was proposed as the ultimate solution for this issue [1-3]. There are two types of magnetic printing methods, which are 'Bit Printing (BP)' and 'Edge Printing (EP)'. BP method is conducted by applying external field whose direction is vertical to the plane of both master disk (Master) and perpendicular magnetic recording (PMR) media (Slave). On the other hand, EP method is conducted by applying external field toward down track direction of both master and slave. In BP for bit length shorter than 100 nm, the SNR of perpendicular anisotropic master was higher than isotropic master. And the SNR of EP for the bit length shorter than 50 nm was demonstrated.

  16. Master curves and radial distribution functions for shear dilatancy of liquid n-hexadecane via nonequilibrium molecular dynamics simulations.

    PubMed

    Tseng, Huan-Chang; Wu, Jiann-Shing; Chang, Rong-Yeu

    2009-04-28

    Shear dilatancy, a significant nonlinear behavior of nonequilibrium thermodynamics states, has been observed in nonequilibrium molecular dynamics (NEMD) simulations for liquid n-hexadecane fluid under extreme shear conditions. The existence of shear dilatancy is relevant to the relationship between the imposed shear rate gamma and the critical shear rate gamma(c). Consequently, as gammagamma(c), the intermolecular distance is lengthened substantially by strong shear deformation breaking the equilibrium thermodynamic state so that shear dilatancy takes place. Notably, a characteristic shear rate gamma(m), which depends on the root mean square molecular velocity and the average free molecular distance, is found in nonequilibrium thermodynamics state curves. Studies of the variations in the intermolecular radial distribution function (RDF) with respect to the shear rate provide a direct measure of the variation in the degree of intermolecular separation. Additionally, the variations of the RDF curve in the microscopic regime are consistent with those of the nonequilibrium thermodynamic state in the macroscopic world. By inspecting the overall shape of the RDF curve, it can be readily corroborated that the fluid of interest exists in the liquid state. More importantly, both primary characteristic values, the equilibrium thermodynamic state variable and a particular shear rate of gamma(p), are determined cautiously, with gamma(p) depending on the gamma(m) value and the square root of pressure. Thereby, the nonequilibrium thermodynamic state curves can be normalized as temperature-, pressure-, and density-invariant master curves, formulated by applying the Cross constitutive equation. Clearly, gamma(c) occurs at which a reduced shear rate gamma/gamma(p) approaches 0.1. Furthermore, the trends in the rates of shear dilatancy in both the constant-pressure and constant-volume NEMD systems under isothermal conditions conform to the cyclic rule of pressure, as a function of density and shear rate.

  17. Quantum trajectories for time-dependent adiabatic master equations

    NASA Astrophysics Data System (ADS)

    Yip, Ka Wa; Albash, Tameem; Lidar, Daniel A.

    2018-02-01

    We describe a quantum trajectories technique for the unraveling of the quantum adiabatic master equation in Lindblad form. By evolving a complex state vector of dimension N instead of a complex density matrix of dimension N2, simulations of larger system sizes become feasible. The cost of running many trajectories, which is required to recover the master equation evolution, can be minimized by running the trajectories in parallel, making this method suitable for high performance computing clusters. In general, the trajectories method can provide up to a factor N advantage over directly solving the master equation. In special cases where only the expectation values of certain observables are desired, an advantage of up to a factor N2 is possible. We test the method by demonstrating agreement with direct solution of the quantum adiabatic master equation for 8-qubit quantum annealing examples. We also apply the quantum trajectories method to a 16-qubit example originally introduced to demonstrate the role of tunneling in quantum annealing, which is significantly more time consuming to solve directly using the master equation. The quantum trajectories method provides insight into individual quantum jump trajectories and their statistics, thus shedding light on open system quantum adiabatic evolution beyond the master equation.

  18. Teaching the right hydrology with minimum resources in Ethiopia

    NASA Astrophysics Data System (ADS)

    Steenhuis, Tammo; Collick, Amy; Wondie, Ayalew; Jemberu, Tsehai

    2010-05-01

    This presentation will highlight our experience in teaching 19 Master's students from diverse backgrounds hydrology and watershed management in Ethiopia. Although the program was based at Bahir Dar University on the shores of Lake Tana in Ethiopia, the students received an US degree. The goal was to train professionals who can help to institute more effective and sustainable watershed management practices in Ethiopia. Teaching hydrology was a challenge. From the literature and personal observation, it was obvious that the traditional techniques of predicting runoff based on infiltration excess runoff and SCS curve number method were not satisfactory. Saturation excess runoff was more likely. However there was no research to prove that it actually was the case. In class we taught both runoff principles but stressed the saturation excess runoff. It was impossible to convince the students that the techniques that came from the western world be incorrect. For their Masters thesis, eight students did field research on runoff and erosion processes in watershed (some of which has a long record of discharge and sediment data). The students recorded water table heights, measured infiltration rates and determined where most erosion took place in the landscape. Based on this data they modeled the previously observed discharge successful using a saturation excess type model. From these studies we could establish that saturation in the landscape had a great effect on both runoff and sediment losses. As result of the field work, students had changed their mind about the appropriateness of using for example the SCS curve number method in Ethiopian highlands Perhaps the lesson to be learned is that we do not need a lot of funds to teach students the right hydrology. However, there is no substitute for going out in the field and experiencing what the right hydrology is by studying the processes in the landscape itself. By simply teaching in class, students will and cannot accept that the hydrologic processes that were taught for a century might be incorrect.

  19. Dynamics of Li+ ions in Li2O-TeO2-P2O5 glasses

    NASA Astrophysics Data System (ADS)

    Chatterjee, A.; Ghosh, A.

    2018-04-01

    In the present work we have studied transport properties of lithium ions in 0.3Li2O-0.7[xTeO2-(1-x)P2O5] glasses, where x=0.5, 0.6, 0.7. We have measured acconductivity for a wide range offrequency and temperature. The real part of the conductivity spectra has been analyzed by the power law in Almond-West formalism. The dc conductivity has been obtained from the complex impedance plots. We have found that dc conductivity increases and activation energy decreases on increase of TeO2 for a particular Li2O content. We have also found that the dc conductivity and crossover frequency obey Arrhenius relation. The time temperature superposition has been verified using the scaling formalism of the conductivity spectra. We have found that the conductivity isotherms scaled to a single master curve with suitable scaling parameters for a particular composition at different temperatures. However the scaling to a single master curve fails for different compositions at a particular temperature.

  20. Fracture toughness of irradiated modified 9Cr-1Mo steel

    NASA Astrophysics Data System (ADS)

    Kim, Sung Ho; Yoon, Ji-Hyun; Ryu, Woo Seog; Lee, Chan Bock; Hong, Jun Hwa

    2009-04-01

    The effects of irradiation on fracture toughness of modified 9Cr-1Mo steel in the transition region were investigated. Half size precracked Charpy specimens were irradiated up to 1.2 × 10 21n/cm 2 ( E > 0.1 MeV) at 340 °C and 400 °C in the Korean research reactor. The irradiation induced transition temperature shift for a modified 9Cr-1Mo was evaluated by using the Master Curve methodology. The T0 temperature for the unirradiated specimens were measured as -67.7 °C and -72.4 °C from the tests with standard PCVN (precracked charpy V-notch) and half sized PCVN specimens, respectively. The T0 shifts of specimens after irradiation at 340 °C and 400 °C were 70.7 °C and 66.1 °C, respectively. The Weibull slopes for the fracture toughness data obtained from the unirradiated and irradiated modified 9Cr-1Mo steels were determined to confirm the applicability of master curve methodology to modified 9Cr-1Mo steel.

  1. Hydrodynamic entrainment in micro-confined suspensions and its implications for two-point microrheology

    NASA Astrophysics Data System (ADS)

    Aponte-Rivera, Christian; Zia, Roseanna N.

    2017-11-01

    We study hydrodynamic entrainment in spherically confined colloidal suspensions of hydrodynamically interacting particles as a model system for intracellular and other micro-confined biophysical transport. Modeling of transport and rheology in such materials requires an accurate description of the microscopic forces driving particle motion and of particle interactions with nearby boundaries. We carry out dynamic simulations of concentrated, spherically confined colloids as a model system to study the effect of 3D confinement on entrainment and rheology. We show that entrainment between two tracer particles exhibits qualitatively different functional dependence on inter-particle separation as compared to an unbound suspension, and develop a scaling theory that collapses the concentrated mobility of spherically confined suspensions for all volume fractions and particle to cavity size ratios onto a master curve. For widely separated particles, the master curve can be predicted via a Green's function, which suggests a framework with which to conduct two-point microrheology measurements near confining boundaries. The implications of these results for experiments in micro-confined biophysical systems, such as the interior of eukaryotic cells, are discussed.

  2. 48 CFR 217.7103-1 - Content and format of master agreements.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... master agreements. 217.7103-1 Section 217.7103-1 Federal Acquisition Regulations System DEFENSE... CONTRACTING METHODS Master Agreement for Repair and Alteration of Vessels 217.7103-1 Content and format of master agreements. Follow the procedures at PGI 217.7103-1 for preparation of master agreements. [71 FR...

  3. 48 CFR 217.7103-1 - Content and format of master agreements.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... master agreements. 217.7103-1 Section 217.7103-1 Federal Acquisition Regulations System DEFENSE... CONTRACTING METHODS Master Agreement for Repair and Alteration of Vessels 217.7103-1 Content and format of master agreements. Follow the procedures at PGI 217.7103-1 for preparation of master agreements. [71 FR...

  4. 48 CFR 217.7103-1 - Content and format of master agreements.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... master agreements. 217.7103-1 Section 217.7103-1 Federal Acquisition Regulations System DEFENSE... CONTRACTING METHODS Master Agreement for Repair and Alteration of Vessels 217.7103-1 Content and format of master agreements. Follow the procedures at PGI 217.7103-1 for preparation of master agreements. [71 FR...

  5. 48 CFR 217.7103-1 - Content and format of master agreements.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... master agreements. 217.7103-1 Section 217.7103-1 Federal Acquisition Regulations System DEFENSE... CONTRACTING METHODS Master Agreement for Repair and Alteration of Vessels 217.7103-1 Content and format of master agreements. Follow the procedures at PGI 217.7103-1 for preparation of master agreements. [71 FR...

  6. 48 CFR 217.7103-1 - Content and format of master agreements.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... master agreements. 217.7103-1 Section 217.7103-1 Federal Acquisition Regulations System DEFENSE... CONTRACTING METHODS Master Agreement for Repair and Alteration of Vessels 217.7103-1 Content and format of master agreements. Follow the procedures at PGI 217.7103-1 for preparation of master agreements. [71 FR...

  7. Critical behaviour and filed dependence of magnetic entropy change in K-doped manganites Pr0.8Na0.2-xKxMnO3 (x = 0.10 and 0.15)

    NASA Astrophysics Data System (ADS)

    Ben Khlifa, H.; M'nassri, R.; Tarhouni, S.; Regaieg, Y.; Cheikhrouhou-Koubaa, W.; Chniba-Boudjada, N.; Cheikhrouhou, A.

    2018-01-01

    The orthorhombic Pr0.8Na0.2-xKxMnO3 (x = 0.10 and 0.15) manganites are prepared by using the solid state reaction at high temperatures. The critical exponents (β, γ, δ) are investigated through various techniques such as modified Arrott plot, Kouvel-Fisher method and critical isotherm analysis based on the data of the magnetic measurements recorded around the Curie temperature. The critical exponents are derived from the magnetization data using the Kouvel-Fisher method, are found to be β = 0.32(4) and γ = 1.29(2) at TC 123 K for x = 0.10 and β = 0.31(1) and γ = 1.25(2) at TC 133 K for x = 0.15. The critical exponent values obtained for both samples are comparable to the values predicted by the 3D-Ising model, and have also been verified by the scaling equation of state. Such results demonstrate the existence of ferromagnetic short-range order in our materials. The magnetic entropy changes of polycrystalline samples with a second-order phase transition are investigated. A large magnetic entropy change deduced from isothermal magnetization curves, is observed in our samples with a peak centered on their respective Curie temperatures (TC). The field dependence of the magnetic entropy changes are analyzed, which show power law dependence ΔSmax ≈ a(μ0 H) n at transition temperature. The values of n obey to the Curie Weiss law above the transition temperature. It is shown that for the investigated materials, the magnetic entropy change follow a master curve behaviour. The rescaled magnetic entropy change curves for different applied fields collapse onto a single curve for both samples.

  8. Low-cost replicable plastic HUD combiner element

    NASA Astrophysics Data System (ADS)

    Kress, Bernard; Raulot, Victorien; St. Hilaire, Pierre; Meyrueis, Patrick

    2009-05-01

    We present a novel technique to fabricate low cost mass replicable plastic HUDs for the transportation industry. HUD are implemented in numerous sectors today (in avionics, automobile, military, machinery,...). Typical implementations include an optical combiner which produces the desired virtual image while leaving the field mostly unaffected by the optics. Such combiners optics are usually implemented as cumbersome catadioptric devices in automobile, dichroic coated curved plates, or expensive volume holograms in commercial and military aviation. We propose a novel way to design, model and fabricate combiner masters which can be replicated in mass by UV casting in plastic. We review the various design techniques required for such elements and the novel mastering technology.

  9. Sandstone and shale compaction curves derived from sonic and gamma ray logs in offshore wells, North Slope, Alaska; parameters for basin modeling

    USGS Publications Warehouse

    Rowan, Elisabeth L.; Hayba, Daniel O.; Nelson, Philip H.; Burns, W. Matthew; Houseknecht, David W.

    2003-01-01

    Representative compaction curves for the principle lithologies are essential input for reliable models of basin history. Compaction curves influence estimates of maximum burial and erosion. Different compaction curves may produce significantly different thermal histories. Default compaction curves provided by basin modeling packages may or may not be a good proxy for the compaction properties in a given area. Compaction curves in the published literature span a wide range, even within one lithology, e.g., sandstone (see Panel 3). An abundance of geophysical well data for the North Slope, from both government and private sources, provides us with an unusually good opportunity to develop compaction curves for the Cretaceous-Tertiary Brookian sandstones, siltstones, and shales. We examined the sonic and gamma ray logs from 19 offshore wells (see map), where significant erosion is least likely to have occurred. Our data are primarily from the Cretaceous-Tertiary Brookian sequence and are less complete for older sequences. For each well, the fraction of shale (Vsh) at a given depth was estimated from the gamma ray log, and porosity was computed from sonic travel time. By compositing porosities for the near-pure sand (Vsh99%)from many individual wells we obtained data over sufficient depth intervals to define sandstone and shale 'master' compaction curves. A siltstone curve was defined using the sonic-derived porosities for Vsh values of 50%. These compaction curves generally match most of the sonic porosities with an error of 5% or less. Onshore, the curves are used to estimate the depth of maximum burial at the end of Brookian sedimentation. The depth of sonic-derived porosity profiles is adjusted to give the best match with the 'master' compaction curves. The amount of the depth adjustment is the erosion estimate. Using our compaction curves, erosion estimates on the North Slope range from zero in much of the offshore, to as much as 1500 ft along the coast, and to more than 10,000 ft in the foothills (Panel 3). Compaction curves provide an alternative to vitrinite reflectance for estimating erosion. Vitrinite reflectance data are often very sparse in contrast to well log data and are subject to inconsistencies when measurements are made by different labs. The phenomenon of 'recycling' can also make the reflectance values of dispersed vitrinite problematic for quantifying erosion. Recycling is suspected in dispersed vitrinite in North Slope rocks, particularly in the younger, Cretaceous-Tertiary section. The compaction curves defined here are being integrated into our burial history and thermal models to determine the timing of source rock maturation. An example on Panel 3 shows the results of calculating the maturity of the Shublik Fm. at the Tulaga well using two different sets of shale and siltstone compaction curves. Finally, accurate compaction curves improve a model's ability to realistically simulate the pressure regime during burial, including overpressures.

  10. System maintenance manual for master modeling of aerodynamic surfaces by three-dimensional explicit representation

    NASA Technical Reports Server (NTRS)

    Gibson, A. F.

    1983-01-01

    A system of computer programs has been developed to model general three-dimensional surfaces. Surfaces are modeled as sets of parametric bicubic patches. There are also capabilities to transform coordinate to compute mesh/surface intersection normals, and to format input data for a transonic potential flow analysis. A graphical display of surface models and intersection normals is available. There are additional capabilities to regulate point spacing on input curves and to compute surface intersection curves. Internal details of the implementation of this system are explained, and maintenance procedures are specified.

  11. Shaping ability and safety of five different rotary nickel-titanium instruments compared with stainless steel hand instrumentation in simulated curved root canals.

    PubMed

    Schirrmeister, Jörg F; Strohl, Christian; Altenburger, Markus J; Wrbas, Karl-Thomas; Hellwig, Elmar

    2006-06-01

    To compare the shaping ability and safety of engine-driven FlexMaster, GT Rotary, ProFile, ProTaper, and RaCe rotary instrumentation and Hedström hand instrumentation in simulated root canals. One hundred fifty simulated colored root canals with a curvature of 20 degrees and a radius of 10 mm were randomly distributed among 6 groups of 25 specimens each. After preparation to apical size 30 the area of remaining color on the canal wall indicating unprepared areas was measured in mm2 using image analyzer software. Specimens treated with RaCe left least areas of remaining color compared to all other groups (P < .001), followed by ProTaper. Preparation with ProFile left behind the highest amount of unprepared areas. The ProFile group revealed significantly more remaining color than ProTaper, GT Rotary, and FlexMaster (P < .05). Four FlexMaster files separated. RaCe rotary files were safe and more effective compared to the other instruments.

  12. Methods Used for the Assessment of Student Outcomes from Master's Degree Programs in Organizational Leadership

    ERIC Educational Resources Information Center

    Pugh, Joseph W. T.

    2009-01-01

    This descriptive, non-experimental, cross-sectional study inquired into the methods used to assess the student outcomes of master's degree programs in organizational leadership. A survey questionnaire was submitted to the directors of master's degree programs in organizational leadership at ninety-three not-for-profit institutions of higher…

  13. 48 CFR 14.203-3 - Master solicitation.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... 48 Federal Acquisition Regulations System 1 2012-10-01 2012-10-01 false Master solicitation. 14... CONTRACTING METHODS AND CONTRACT TYPES SEALED BIDDING Solicitation of Bids 14.203-3 Master solicitation. The master solicitation is provided to potential sources who are requested to retain it for continued and...

  14. 48 CFR 14.203-3 - Master solicitation.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 48 Federal Acquisition Regulations System 1 2011-10-01 2011-10-01 false Master solicitation. 14... CONTRACTING METHODS AND CONTRACT TYPES SEALED BIDDING Solicitation of Bids 14.203-3 Master solicitation. The master solicitation is provided to potential sources who are requested to retain it for continued and...

  15. 48 CFR 14.203-3 - Master solicitation.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 48 Federal Acquisition Regulations System 1 2010-10-01 2010-10-01 false Master solicitation. 14... CONTRACTING METHODS AND CONTRACT TYPES SEALED BIDDING Solicitation of Bids 14.203-3 Master solicitation. The master solicitation is provided to potential sources who are requested to retain it for continued and...

  16. 48 CFR 14.203-3 - Master solicitation.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... 48 Federal Acquisition Regulations System 1 2014-10-01 2014-10-01 false Master solicitation. 14... CONTRACTING METHODS AND CONTRACT TYPES SEALED BIDDING Solicitation of Bids 14.203-3 Master solicitation. The master solicitation is provided to potential sources who are requested to retain it for continued and...

  17. 48 CFR 14.203-3 - Master solicitation.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... 48 Federal Acquisition Regulations System 1 2013-10-01 2013-10-01 false Master solicitation. 14... CONTRACTING METHODS AND CONTRACT TYPES SEALED BIDDING Solicitation of Bids 14.203-3 Master solicitation. The master solicitation is provided to potential sources who are requested to retain it for continued and...

  18. Dual arm master controller for a bilateral servo-manipulator

    DOEpatents

    Kuban, Daniel P.; Perkins, Gerald S.

    1989-01-01

    A master controller for a mechanically dissimilar bilateral slave servo-manipulator is disclosed. The master controller includes a plurality of drive trains comprising a plurality of sheave arrangements and cables for controlling upper and lower degrees of master movement. The cables and sheaves of the master controller are arranged to effect kinematic duplication of the slave servo-manipulator, despite mechanical differences therebetween. A method for kinematically matching a master controller to a slave servo-manipulator is also disclosed.

  19. Electrorheological suspensions of laponite in oil: rheometry studies.

    PubMed

    Parmar, K P S; Méheust, Y; Schjelderupsen, Børge; Fossum, J O

    2008-03-04

    We have studied the effect of an external direct current (DC) electric field ( approximately 1 kV/mm) on the rheological properties of colloidal suspensions consisting of aggregates of laponite particles in a silicone oil. Microscopy observations show that, under application of an electric field greater than a triggering electric field Ec approximately 0.6 kV/mm, laponite aggregates assemble into chain- and/or columnlike structures in the oil. Without an applied electric field, the steady-state shear behavior of such suspensions is Newtonian-like. Under application of an electric field larger than Ec, it changes dramatically as a result of the changes in the microstructure: a significant yield stress is measured, and under continuous shear the fluid is shear-thinning. The rheological properties, in particular the dynamic and static shear stress, were studied as a function of particle volume fraction for various strengths (including null) of the applied electric field. The flow curves at constant shear rate can be scaled with respect to both the particle fraction and electric field strength onto a master curve. This scaling is consistent with simple scaling arguments. The shape of the master curve accounts for the system's complexity; it approaches a standard power-law model at high Mason numbers. Both dynamic and static yield stresses are observed to depend on the particle fraction Phi and electric field E as PhibetaEalpha, with alpha approximately 1.85 and beta approximately 1 and 1.70 for the dynamic and static yield stresses, respectively. The yield stress was also determined as the critical stress at which there occurs a bifurcation in the rheological behavior of suspensions that are submitted to a constant shear stress; a scaling law with alpha approximately 1.84 and beta approximately 1.70 was obtained. The effectiveness of the latter technique confirms that such electrorheological (ER) fluids can be studied in the framework of thixotropic fluids. The method is very reproducible; we suggest that it could be used routinely for studying ER fluids. The measured overall yield stress behavior of the suspensions may be explained in terms of standard conduction models for electrorheological systems. Interesting prospects include using such systems for guided self-assembly of clay nanoparticles.

  20. Development of duplex real-time PCR for the detection of WSSV and PstDV1 in cultivated shrimp.

    PubMed

    Leal, Carlos A G; Carvalho, Alex F; Leite, Rômulo C; Figueiredo, Henrique C P

    2014-07-05

    The White spot syndrome virus (WSSV) and Penaeus stylirostris penstyldensovirus 1 (previously named Infectious hypodermal and hematopoietic necrosis virus-IHHNV) are two of the most important viral pathogens of penaeid shrimp. Different methods have been applied for diagnosis of these viruses, including Real-time PCR (qPCR) assays. A duplex qPCR method allows the simultaneous detection of two viruses in the same sample, which is more cost-effective than assaying for each virus separately. Currently, an assay for the simultaneous detection of the WSSV and the PstDV1 in shrimp is unavailable. The aim of this study was to develop and standardize a duplex qPCR assay for the simultaneous detection of the WSSV and the PstDV1 in clinical samples of diseased L. vannamei. In addition, to evaluate the performance of two qPCR master mixes with regard to the clinical sensitivity of the qPCR assay, as well as, different methods for qPCR results evaluation. The duplex qPCR assay for detecting WSSV and PstDV1 in clinical samples was successfully standardized. No difference in the amplification of the standard curves was observed between the duplex and singleplex assays. Specificities and sensitivities similar to those of the singleplex assays were obtained using the optimized duplex qPCR. The analytical sensitivities of duplex qPCR were two copies of WSSV control plasmid and 20 copies of PstDV1 control plasmid. The standardized duplex qPCR confirmed the presence of viral DNA in 28 from 43 samples tested. There was no difference for WSSV detection using the two kits and the distinct methods for qPCR results evaluation. High clinical sensitivity for PstDV1 was obtained with TaqMan Universal Master Mix associated with relative threshold evaluation. Three cases of simultaneous infection by the WSSV and the PstDV1 were identified with duplex qPCR. The standardized duplex qPCR was shown to be a robust, highly sensitive, and feasible diagnostic tool for the simultaneous detection of the WSSV and the PstDV1 in whiteleg shrimp. The use of the TaqMan Universal Master Mix and the relative threshold method of data analysis in our duplex qPCR method provided optimal levels of sensitivity and specificity.

  1. Creep-rupture reliability analysis

    NASA Technical Reports Server (NTRS)

    Peralta-Duran, A.; Wirsching, P. H.

    1984-01-01

    A probabilistic approach to the correlation and extrapolation of creep-rupture data is presented. Time temperature parameters (TTP) are used to correlate the data, and an analytical expression for the master curve is developed. The expression provides a simple model for the statistical distribution of strength and fits neatly into a probabilistic design format. The analysis focuses on the Larson-Miller and on the Manson-Haferd parameters, but it can be applied to any of the TTP's. A method is developed for evaluating material dependent constants for TTP's. It is shown that optimized constants can provide a significant improvement in the correlation of the data, thereby reducing modelling error. Attempts were made to quantify the performance of the proposed method in predicting long term behavior. Uncertainty in predicting long term behavior from short term tests was derived for several sets of data. Examples are presented which illustrate the theory and demonstrate the application of state of the art reliability methods to the design of components under creep.

  2. Phase-dependent Photometric and Spectroscopic Characterization of the MASTER-Net Optical Transient J212444.87+321738.3: An Oxygen-rich Mira

    NASA Astrophysics Data System (ADS)

    Ghosh, Supriyo; Mondal, Soumen; Das, Ramkrishna; Banerjee, D. P. K.; Ashok, N. M.; Hambsch, Franz-Josef; Dutta, Somnath

    2018-05-01

    We describe the time-dependent properties of a new spectroscopically confirmed Mira variable, which was discovered in 2013 as MASTER-Net Optical Transient J212444.87+321738.3 toward the Cygnus constellation. We have performed long-term optical/near-infrared (NIR) photometric and spectroscopic observations to characterize the object. From the optical/NIR light curves, we estimate a variability period of 465 ± 30 days. The wavelength-dependent amplitudes of the observed light curves range from ΔI ∼ 4 mag to ΔK ∼ 1.5 mag. The (J ‑ K) color index varies from 1.78 to 2.62 mag over phases. Interestingly, a phase lag of ∼60 days between optical and NIR light curves is also seen, as in other Miras. Our optical/NIR spectra show molecular features of TiO, VO, CO, and strong water bands that are a typical signature of oxygen-rich Mira. We rule out S- or C-type as ZrO bands at 1.03 and 1.06 μm and C2 band at 1.77 μm are absent. We estimate the effective temperature of the object from the Spectral Energy Distribution, and distance and luminosity from standard Period–Luminosity relations. The optical/NIR spectra display time-dependent atomic and molecular features (e.g., TiO, Na I, Ca I, H2O, CO), as commonly observed in Miras. Such spectroscopic observations are useful for studying pulsation variability in Miras.

  3. Long-Term Viscoelastic Response of E-glass/Bismaleimide Composite in Seawater Environment

    NASA Astrophysics Data System (ADS)

    Yian, Zhao; Zhiying, Wang; Keey, Seah Leong; Boay, Chai Gin

    2015-12-01

    The effect of seawater absorption on the long-term viscoelastic response of E-glass/BMI composite is presented in this paper. The diffusion of seawater into the composite shows a two-stage behavior, dominated by Fickian diffusion initially and followed by polymeric relaxation. The Glass transition temperature (Tg) of the composite with seawater absorption is considerably lowered due to the plasticization effect. However the effect of water absorption at 50 °C is found to be reversible after drying process. The time-temperature superposition (TTS) was performed based on the results of Dynamic Mechanical Analysis to construct the master curve of storage modulus. The shift factors exhibit Arrhenius behavior when temperature is well below Tg and Vogel-Fulcher-Tammann (VFT) like behavior when temperature gets close to glass transition region. As a result, a semi-empirical formulation is proposed to account for the seawater absorption effect in predicting long-term viscoelastic response of BMI composites based on temperature dependent storage modulus and TTS. The predicted master curves show that the degradation of storage modulus accelerates with both seawater exposure and increasing temperature. The proposed formulation can be applied to predict the long-term durability of any thermorheologically simple composite materials in seawater environment.

  4. Thermodynamic scaling in ionically conducting glasses and melts

    NASA Astrophysics Data System (ADS)

    Habasaki, Junko

    2013-02-01

    Molecular dynamics simulations have been performed to learn temperature, composition, pressure dependencies of the diffusivity and structures in the system having ion channels and network formers. Validity of the thermodynamic scaling in the lithium silicate glasses and melts is shown, where the scaling concept is extended with an aid of a percolation aspect of the ion channels. All diffusion coefficients of ions of different compositions, temperatures, pressures are successfully represented by a single master curve as a function of system volumes, temperatures and volume fraction of M2O part. It enables us to predict the diffusivity in different conditions. Furthermore, it suggests an applicability of scaling concept for the sub-structures in more complex systems. Nearby points on the master curve have the comparable MSD as well as self-part of the van Hove functions. Similarity is observed from an early term region. This observation is consistent to our previous claims [K. L. Ngai, J. Habasaki, D. Prevosto, S. Capaccioli, Marian Paluch, J. Chem. Phys. 137, 034511 (2012)] that the thermodynamic scaling of α-Relaxation time stems from the Johari-Goldstein β-relaxation or the primitive relaxation of the coupling model.

  5. User's manual for master: Modeling of aerodynamic surfaces by 3-dimensional explicit representation. [input to three dimensional computational fluid dynamics

    NASA Technical Reports Server (NTRS)

    Gibson, S. G.

    1983-01-01

    A system of computer programs was developed to model general three dimensional surfaces. Surfaces are modeled as sets of parametric bicubic patches. There are also capabilities to transform coordinates, to compute mesh/surface intersection normals, and to format input data for a transonic potential flow analysis. A graphical display of surface models and intersection normals is available. There are additional capabilities to regulate point spacing on input curves and to compute surface/surface intersection curves. Input and output data formats are described; detailed suggestions are given for user input. Instructions for execution are given, and examples are shown.

  6. A systematic and efficient method to compute multi-loop master integrals

    NASA Astrophysics Data System (ADS)

    Liu, Xiao; Ma, Yan-Qing; Wang, Chen-Yu

    2018-04-01

    We propose a novel method to compute multi-loop master integrals by constructing and numerically solving a system of ordinary differential equations, with almost trivial boundary conditions. Thus it can be systematically applied to problems with arbitrary kinematic configurations. Numerical tests show that our method can not only achieve results with high precision, but also be much faster than the only existing systematic method sector decomposition. As a by product, we find a new strategy to compute scalar one-loop integrals without reducing them to master integrals.

  7. Cloning SU8 silicon masters using epoxy resins to increase feature replicability and production for cell culture devices.

    PubMed

    Kamande, J W; Wang, Y; Taylor, A M

    2015-05-01

    In recent years, there has been a dramatic increase in the use of poly(dimethylsiloxane) (PDMS) devices for cell-based studies. Commonly, the negative tone photoresist, SU8, is used to pattern features onto silicon wafers to create masters (SU8-Si) for PDMS replica molding. However, the complexity in the fabrication process, low feature reproducibility (master-to-master variability), silane toxicity, and short life span of these masters have been deterrents for using SU8-Si masters for the production of cell culture based PDMS microfluidic devices. While other techniques have demonstrated the ability to generate multiple devices from a single master, they often do not match the high feature resolution (∼0.1 μm) and low surface roughness that soft lithography masters offer. In this work, we developed a method to fabricate epoxy-based masters that allows for the replication of features with high fidelity directly from SU8-Si masters via their PDMS replicas. By this method, we show that we could obtain many epoxy based masters with equivalent features to a single SU8-Si master with a low feature variance of 1.54%. Favorable feature transfer resolutions were also obtained by using an appropriate Tg epoxy based system to ensure minimal shrinkage of features ranging in size from ∼100 μm to <10 μm in height. We further show that surface coating epoxy masters with Cr/Au lead to effective demolding and yield PDMS chambers that are suitable for long-term culturing of sensitive primary hippocampal neurons. Finally, we incorporated pillars within the Au-epoxy masters to eliminate the process of punching media reservoirs and thereby reducing substantial artefacts and wastage.

  8. Cloning SU8 silicon masters using epoxy resins to increase feature replicability and production for cell culture devices

    PubMed Central

    Kamande, J. W.; Wang, Y.; Taylor, A. M.

    2015-01-01

    In recent years, there has been a dramatic increase in the use of poly(dimethylsiloxane) (PDMS) devices for cell-based studies. Commonly, the negative tone photoresist, SU8, is used to pattern features onto silicon wafers to create masters (SU8-Si) for PDMS replica molding. However, the complexity in the fabrication process, low feature reproducibility (master-to-master variability), silane toxicity, and short life span of these masters have been deterrents for using SU8-Si masters for the production of cell culture based PDMS microfluidic devices. While other techniques have demonstrated the ability to generate multiple devices from a single master, they often do not match the high feature resolution (∼0.1 μm) and low surface roughness that soft lithography masters offer. In this work, we developed a method to fabricate epoxy-based masters that allows for the replication of features with high fidelity directly from SU8-Si masters via their PDMS replicas. By this method, we show that we could obtain many epoxy based masters with equivalent features to a single SU8-Si master with a low feature variance of 1.54%. Favorable feature transfer resolutions were also obtained by using an appropriate Tg epoxy based system to ensure minimal shrinkage of features ranging in size from ∼100 μm to <10 μm in height. We further show that surface coating epoxy masters with Cr/Au lead to effective demolding and yield PDMS chambers that are suitable for long-term culturing of sensitive primary hippocampal neurons. Finally, we incorporated pillars within the Au-epoxy masters to eliminate the process of punching media reservoirs and thereby reducing substantial artefacts and wastage. PMID:26180572

  9. The development of method for continuous improvement of master file of the nursing practice terminology.

    PubMed

    Tsuru, Satoko; Okamine, Eiko; Takada, Aya; Watanabe, Chitose; Uchiyama, Makiko; Dannoue, Hideo; Aoyagi, Hisae; Endo, Akira

    2009-01-01

    Nursing Action Master and Nursing Observation Master were released from 2002 to 2008. Two kinds of format, an Excel format and a CSV format file are prepared for maintaining them. Followings were decided as a basic rule of the maintenance: newly addition, revision, deletion, the numbering of the management and a rule of the coding. The master was developed based on it. We do quality assurance for the masters using these rules.

  10. Strain-rate dependence of ramp-wave evolution and strength in tantalum

    DOE PAGES

    Lane, J. Matthew D.; Foiles, Stephen M.; Lim, Hojun; ...

    2016-08-25

    We have conducted molecular dynamics (MD) simulations of quasi-isentropic ramp-wave compression to very high pressures over a range of strain rates from 10 11 down to 10 8 1/s. Using scaling methods, we collapse wave profiles from various strain rates to a master profile curve, which shows deviations when material response is strain-rate dependent. Thus, we can show with precision where, and how, strain-rate dependence affects the ramp wave. We find that strain rate affects the stress-strain material response most dramatically at strains below 20%, and that above 30% strain the material response is largely independent of strain rate. Wemore » show good overall agreement with experimental stress-strain curves up to approximately 30% strain, above which simulated response is somewhat too stiff. We postulate that this could be due to our interatomic potential or to differences in grain structure and/or size between simulation and experiment. Strength is directly measured from per-atom stress tensor and shows significantly enhanced elastic response at the highest strain rates. As a result, this enhanced elastic response is less pronounced at higher pressures and at lower strain rates.« less

  11. Using the QUAIT Model to Effectively Teach Research Methods Curriculum to Master's-Level Students

    ERIC Educational Resources Information Center

    Hamilton, Nancy J.; Gitchel, Dent

    2017-01-01

    Purpose: To apply Slavin's model of effective instruction to teaching research methods to master's-level students. Methods: Barriers to the scientist-practitioner model (student research experience, confidence, and utility value pertaining to research methods as well as faculty research and pedagogical incompetencies) are discussed. Results: The…

  12. Autonomic cardiovascular modulation in masters and young cyclists following high-intensity interval training.

    PubMed

    Borges, Nattai R; Reaburn, Peter R; Doering, Thomas M; Argus, Christos K; Driller, Matthew W

    2017-04-01

    This study aimed at examining the autonomic cardiovascular modulation in well-trained masters and young cyclists following high-intensity interval training (HIT). Nine masters (age 55.6 ± 5.0 years) and eight young cyclists (age 25.9 ± 3.0 years) completed a HIT protocol of 6 x 30 sec at 175% of peak power output, with 4.5-min' rest between efforts. Immediately following HIT, heart rate and R-R intervals were monitored for 30-min during passive supine recovery. Autonomic modulation was examined by i) heart rate recovery in the first 60-sec of recovery (HRR 60 ); ii) the time constant of the 30-min heart rate recovery curve (HRRτ); iii) the time course of the root mean square for successive 30-sec R-R interval (RMSSD 30 ); and iv) time and frequency domain analyses of subsequent 5-min R-R interval segments. No significant between-group differences were observed for HRR 60 (P = 0.096) or HRR τ (P = 0.617). However, a significant interaction effect was found for RMSSD 30 (P = 0.021), with the master cyclists showing higher RMSSD 30 values following HIT. Similar results were observed in the time and frequency domain analyses with significant interaction effects found for the natural logarithm of the RMSSD (P = 0.008), normalised low-frequency power (P = 0.016) and natural logarithm of high-frequency power (P = 0.012). Following high-intensity interval training, master cyclists demonstrated greater post-exercise parasympathetic reactivation compared to young cyclists, indicating that physical training at older ages has significant effects on autonomic function.

  13. Composite Material Aircraft Electromagnetic Properties and Design Guidelines

    DTIC Science & Technology

    1981-01-01

    Diode Characteristics for IN914 Diode at 220 MHz 7-6 7.5 Characteristics of a 2N2369A Transitor With and Without RF Interference on the Collector Lead...Analylsi Miser Reiponse Model Adjacent Channel Interference Summary 7. STATISTICAL AND NUMERICAL I. PROPAGATION MODELS ANALYSIS MASTER PROPAGATION SYSTEM...Propagation System lIPS) Simsulationst Smorothe Curve Smooth Earth (SCSIS) Oemtralltzd File Statistics Analyzer (Q63) flislance Free Space Spherical Raflectiot

  14. Thermodynamic scaling of dynamic properties of liquid crystals: Verifying the scaling parameters using a molecular model

    NASA Astrophysics Data System (ADS)

    Satoh, Katsuhiko

    2013-08-01

    The thermodynamic scaling of molecular dynamic properties of rotation and thermodynamic parameters in a nematic phase was investigated by a molecular dynamic simulation using the Gay-Berne potential. A master curve for the relaxation time of flip-flop motion was obtained using thermodynamic scaling, and the dynamic property could be solely expressed as a function of TV^{γ _τ }, where T and V are the temperature and volume, respectively. The scaling parameter γτ was in excellent agreement with the thermodynamic parameter Γ, which is the logarithm of the slope of a line plotted for the temperature and volume at constant P2. This line was fairly linear, and as good as the line for p-azoxyanisole or using the highly ordered small cluster model. The equivalence relation between Γ and γτ was compared with results obtained from the highly ordered small cluster model. The possibility of adapting the molecular model for the thermodynamic scaling of other dynamic rotational properties was also explored. The rotational diffusion constant and rotational viscosity coefficients, which were calculated using established theoretical and experimental expressions, were rescaled onto master curves with the same scaling parameters. The simulation illustrates the universal nature of the equivalence relation for liquid crystals.

  15. THE NEW ECLIPSING CV MASTER OTJ192328.22+612413.5—A POSSIBLE SW SEXTANTIS STAR

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Kennedy, M. R.; Callanan, P.; Bouanane, S.

    2016-07-01

    We present optical photometry and spectroscopy of the new eclipsing cataclysmic variable MASTER OTJ192328.22+612413.5, discovered by the MASTER team. We find the orbital period to be P = 0.16764612(5) day/4.023507(1) hr. The depth of the eclipse (2.9 ± 0.1 mag) suggests that the system is nearly edge on, and modeling of the system confirms the inclination to be between 81.°3 and 83.°6. The brightness outside the eclipse varies between observations, with a change of 1.6 ± 0.1 mag. Spectroscopy reveals double-peaked Balmer emission lines. By using spectral features matching a late M-type companion, we bound the distance to be 750more » ± 250 pc, depending on the companion’s spectral type. The source displays 2 mag brightness changes on timescales of days. The amplitude of these changes, along with the spectrum at the faint state, suggest that the system is possibly a dwarf nova. The lack of any high-excitation He ii lines suggests that this system is not magnetically dominated. The light curve in both quiescence and outburst resembles that of Lanning 386, implying MASTER OTJ192328.22+612413.5 is a possible cross between a dwarf nova and a SW Sextantis star.« less

  16. Free volume study on the miscibility of PEEK/PEI blend using positron annihilation and dynamic mechanical thermal analysis

    NASA Astrophysics Data System (ADS)

    Ramani, R.; Alam, S.

    2015-06-01

    High performance polymer blend of poly(ether ether ketone) (PEEK) and poly(ether imide) (PEI) was examined for their free volume behaviour using positron annihilation lifetime spectroscopy and dynamic mechanical thermal analysis methods. The fractional free volume obtained from PALS shows a negative deviation from linear additivity rule implying good miscibility between PEEK and PEI. The dynamic modulus and loss tangent were obtained for the blends at three different frequencies 1, 10 and 100 Hz at temperatures close to and above their glass transition temperature. Applying Time-Temperature-Superposition (TTS) principle to the DMTA results, master curves were obtained at a reference temperature To and the WLF coefficients c01 and c02 were evaluated. Both the methods give similar results for the dependence of fractional free volume on PEI content in this blend. The results reveal that free volume plays an important role in determining the visco-elastic properties in miscible polymer blends.

  17. A Holocene paleosecular variation from 14C-dated volcanic rocks in Western North America

    USGS Publications Warehouse

    Hagstrum, J.T.; Champion, D.E.

    2002-01-01

    A paleosecular variation (PSV) curve for western North America is presented on the basis of 94 virtual geomagnetic poles (VGPs) from dated volcanic rocks sampled at 446 sites. Approximately 60% of the paleomagnetic database has been previously published. A curve defined by "spherical smoothed splines" is fitted to the VGPs, ranked by the quality of the age determinations, where the data density is highest between 3690 and -30 years before present (B.P.) (A.D. 1950), between 7800 and 7050 years B.P., and between 14,060 and 12,700 years B.P. The younger segments of the curve derived from volcanic rocks are similar but less complex than other high-resolution PSV curves derived from lacustrine sediments, particularly the record at Fish Lake, Oregon. The PSV record from lava flows (PSVL), however, is perhaps more reliable in its general shape and chronology because of the higher fidelity of volcanic rocks as magnetic field recorders and because of the greater density of 14C dates. The new PSVL record provides a partial Holocene master curve for western North America and will be of particular value in dating geological and archeological materials using paleomagnetic directions.

  18. Cardiovascular Effects of 1 Year of Progressive and Vigorous Exercise Training in Previously Sedentary Individuals Older Than 65 Years of Age

    PubMed Central

    Fujimoto, Naoki; Prasad, Anand; Hastings, Jeffrey L.; Arbab-Zadeh, Armin; Bhella, Paul S.; Shibata, Shigeki; Palmer, Dean; Levine, Benjamin D.

    2013-01-01

    Background Healthy but sedentary aging leads to cardiovascular stiffening, whereas life-long endurance training preserves left ventricular (LV) compliance. However, it is unknown whether exercise training started later in life can reverse the effects of sedentary behavior on the heart. Methods and Results Twelve sedentary seniors and 12 Masters athletes were thoroughly screened for comorbidities. Subjects underwent invasive hemodynamic measurements with pulmonary artery catheterization to define Starling and LV pressure-volume curves; secondary functional outcomes included Doppler echocardiography, magnetic resonance imaging assessment of cardiac morphology, arterial stiffness (total aortic compliance and arterial elastance), and maximal exercise testing. Nine of 12 sedentary seniors (70.6±3 years; 6 male, 3 female) completed 1 year of endurance training followed by repeat measurements. Pulmonary capillary wedge pressures and LV end-diastolic volumes were measured at baseline, during decreased cardiac filling with lower-body negative pressure, and increased filling with saline infusion. LV compliance was assessed by the slope of the pressure-volume curve. Before training, V̇O2max, LV mass, LV end-diastolic volume, and stroke volume were significantly smaller and the LV was less compliant in sedentary seniors than Masters athletes. One year of exercise training had little effect on cardiac compliance. However, it reduced arterial elastance and improved V̇O2 max by 19% (22.8±3.4 versus 27.2± 4.3 mL/kg/mL; P<0.001). LV mass increased (10%, 64.5±7.9 versus 71.2±12.3 g/m2; P=0.037) with no change in the mass-volume ratio. Conclusions Although 1 year of vigorous exercise training did not appear to favorably reverse cardiac stiffening in sedentary seniors, it nonetheless induced physiological LV remodeling and imparted favorable effects on arterial function and aerobic exercise capacity. PMID:20956204

  19. High strength semi-active energy absorbers using shear- and mixedmode operation at high shear rates

    NASA Astrophysics Data System (ADS)

    Becnel, Andrew C.

    This body of research expands the design space of semi-active energy absorbers for shock isolation and crash safety by investigating and characterizing magnetorheological fluids (MRFs) at high shear rates ( > 25,000 1/s) under shear and mixed-mode operation. Magnetorheological energy absorbers (MREAs) work well as adaptive isolators due to their ability to quickly and controllably adjust to changes in system mass or impact speed while providing fail-safe operation. However, typical linear stroking MREAs using pressure-driven flows have been shown to exhibit reduced controllability as impact speed (shear rate) increases. The objective of this work is to develop MREAs that improve controllability at high shear rates by using pure shear and mixed shear-squeeze modes of operation, and to present the fundamental theory and models of MR fluids under these conditions. A proof of concept instrument verified that the MR effect persists in shear mode devices at shear rates corresponding to low speed impacts. This instrument, a concentric cylinder Searle cell magnetorheometer, was then used to characterize three commercially available MRFs across a wide range of shear rates, applied magnetic fields, and temperatures. Characterization results are presented both as flow curves according to established practice, and as an alternate nondimensionalized analysis based on Mason number. The Mason number plots show that, with appropriate correction coefficients for operating temperature, the varied flow curve data can be collapsed to a single master curve. This work represents the first shear mode characterization of MRFs at shear rates over 10 times greater than available with commercial rheometers, as well as the first validation of Mason number analysis to high shear rate flows in MRFs. Using the results from the magnetorheometer, a full scale rotary vane MREA was developed as part of the Lightweight Magnetorheological Energy Absorber System (LMEAS) for an SH-60 Seahawk helicopter crew seat. Characterization tests were carried out on the LMEAS using a 40 vol% MRF used in the previous magnetorheometer tests. These were analyzed using both flow curves and apparent viscosity vs. Mason number diagrams. The nondimensionalized Mason number analysis resulted in data for all conditions of temperature, fluid composition, and shear rate, to collapse onto a single characteristic or master curve. Significantly, the temperature corrected Mason number results from both the bench top magnetorheometer and full scale rotary vane MREA collapse to the same master curve. This enhances the ability of designers of MRFs and MREAs to safely and effectively apply characterization data collected in low shear rate, controlled temperature environments to operational environments that may be completely different. Finally, the Searle cell magnetorheometer was modified with an enforced eccentricity to work in both squeeze and shear modes simultaneously to achieve so called squeeze strengthening of the working MRF, thereby increasing the apparent yield stress and the specific energy absorption. By squeezing the active MR fluid, particles undergo compression-assisted aggregation into stronger, more robust columns which resist shear better than single chains. A hybrid model describing the squeeze strengthening behavior is developed, and recommendations are made for using squeeze strengthening to improve practical MREA devices.

  20. 48 CFR 217.7101 - Definitions.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... Section 217.7101 Federal Acquisition Regulations System DEFENSE ACQUISITION REGULATIONS SYSTEM, DEPARTMENT OF DEFENSE CONTRACTING METHODS AND CONTRACT TYPES SPECIAL CONTRACTING METHODS Master Agreement for... master agreement. (2) Is not a contract. (b) Job order— (1) Is a fixed price contract incorporating, by...

  1. 48 CFR 217.7101 - Definitions.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... Section 217.7101 Federal Acquisition Regulations System DEFENSE ACQUISITION REGULATIONS SYSTEM, DEPARTMENT OF DEFENSE CONTRACTING METHODS AND CONTRACT TYPES SPECIAL CONTRACTING METHODS Master Agreement for... master agreement. (2) Is not a contract. (b) Job order— (1) Is a fixed price contract incorporating, by...

  2. 48 CFR 217.7101 - Definitions.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... Section 217.7101 Federal Acquisition Regulations System DEFENSE ACQUISITION REGULATIONS SYSTEM, DEPARTMENT OF DEFENSE CONTRACTING METHODS AND CONTRACT TYPES SPECIAL CONTRACTING METHODS Master Agreement for... master agreement. (2) Is not a contract. (b) Job order— (1) Is a fixed price contract incorporating, by...

  3. 48 CFR 217.7101 - Definitions.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... Section 217.7101 Federal Acquisition Regulations System DEFENSE ACQUISITION REGULATIONS SYSTEM, DEPARTMENT OF DEFENSE CONTRACTING METHODS AND CONTRACT TYPES SPECIAL CONTRACTING METHODS Master Agreement for... master agreement. (2) Is not a contract. (b) Job order— (1) Is a fixed price contract incorporating, by...

  4. 48 CFR 217.7101 - Definitions.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... Section 217.7101 Federal Acquisition Regulations System DEFENSE ACQUISITION REGULATIONS SYSTEM, DEPARTMENT OF DEFENSE CONTRACTING METHODS AND CONTRACT TYPES SPECIAL CONTRACTING METHODS Master Agreement for... master agreement. (2) Is not a contract. (b) Job order— (1) Is a fixed price contract incorporating, by...

  5. Robust master-slave synchronization for general uncertain delayed dynamical model based on adaptive control scheme.

    PubMed

    Wang, Tianbo; Zhou, Wuneng; Zhao, Shouwei; Yu, Weiqin

    2014-03-01

    In this paper, the robust exponential synchronization problem for a class of uncertain delayed master-slave dynamical system is investigated by using the adaptive control method. Different from some existing master-slave models, the considered master-slave system includes bounded unmodeled dynamics. In order to compensate the effect of unmodeled dynamics and effectively achieve synchronization, a novel adaptive controller with simple updated laws is proposed. Moreover, the results are given in terms of LMIs, which can be easily solved by LMI Toolbox in Matlab. A numerical example is given to illustrate the effectiveness of the method. Copyright © 2013 ISA. Published by Elsevier Ltd. All rights reserved.

  6. Stress concentration in periodically rough Hertzian contact: Hertz to soft-flat-punch transition

    PubMed Central

    Raphaël, E.; Léger, L.; Restagno, F.; Poulard, C.

    2016-01-01

    We report on the elastic contact between a spherical lens and a patterned substrate, composed of a hexagonal lattice of cylindrical pillars. The stress field and the size of the contact area are obtained by means of numerical methods: a superposition method of discrete pressure elements and an iterative bisection-like method. For small indentations, a transition from a Hertzian to a soft-flat-punch behaviour is observed when the surface fraction of the substrate that is covered by the pillars is increased. In particular, we present a master curve defined by two dimensionless parameters, which allows one to predict the stress at the centre of the contact region in terms of the surface fraction occupied by pillars. The transition between the limiting contact regimes, Hertzian and soft-flat-punch, is well described by a rational function. Additionally, a simple model to describe the Boussinesq–Cerruti-like contact between the lens and a single elastic pillar, which takes into account the pillar geometry and the elastic properties of the two bodies, is presented. PMID:27713659

  7. An Examination of Final Evaluation Methods Used in Master's Level Counseling Programs.

    ERIC Educational Resources Information Center

    Carney, Jamie S.; Cobia, Debra C.; Shannon, David M.

    1998-01-01

    Reports the findings of a national study examining methods used for final evaluation in master's level counseling programs. Suggests that as faculty review their policies and procedures with regard to student evaluation, these data may provide valuable information concerning methods selection, content, and delivery of feedback to students.…

  8. Comparison of irradiation-induced shifts of K{sub Jc} and Charpy impact toughness for reactor pressure vessel steels

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Sokolov, M.A.; Nanstad, R.K.

    1999-10-01

    The current provisions for determination of the upward temperature shift of the lower-bound static fracture toughness curve due to irradiation of reactor pressure vessel steels are based on the assumption that they are the same as the Charpy 41-J shifts as a consequence of irradiation. The objective of this paper is to evaluate this assumption relative to data reported in open publications. Depending on the specific source, different sizes of fracture toughness specimens, procedures of the K{sub Jc} determination, and fitting functions were used. It was anticipated that the scatter might be reduced by using a consistent approach to analyzemore » the published data. A method employing Weibull statistics is applied to analyze original fracture toughness data of unirradiated and irradiated pressure vessel steels. Application of the master curve concept is used to determine shifts of fracture toughness transition curves. A hyperbolic tangent function is used to fit charpy absorbed energy data. The fracture toughness shifts are compared to Charpy impact shifts evaluated with various criteria. Linear regression analysis showed that for weld metals, on average, the fracture toughness shift is the same as the Charpy 41-J temperature shift, while for base metals, on average, the fracture toughness shift at 41 J is 16% greater than the shift of the Charpy 41-J transition temperature, with both correlations having relatively large 95% confidence intervals.« less

  9. 48 CFR 217.7103-4 - Emergency work.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... Section 217.7103-4 Federal Acquisition Regulations System DEFENSE ACQUISITION REGULATIONS SYSTEM, DEPARTMENT OF DEFENSE CONTRACTING METHODS AND CONTRACT TYPES SPECIAL CONTRACTING METHODS Master Agreement for... soliciting offers, may issue a written job order to a contractor that has previously executed a master...

  10. 48 CFR 217.7103-4 - Emergency work.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... Section 217.7103-4 Federal Acquisition Regulations System DEFENSE ACQUISITION REGULATIONS SYSTEM, DEPARTMENT OF DEFENSE CONTRACTING METHODS AND CONTRACT TYPES SPECIAL CONTRACTING METHODS Master Agreement for... soliciting offers, may issue a written job order to a contractor that has previously executed a master...

  11. 48 CFR 217.7103-4 - Emergency work.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... Section 217.7103-4 Federal Acquisition Regulations System DEFENSE ACQUISITION REGULATIONS SYSTEM, DEPARTMENT OF DEFENSE CONTRACTING METHODS AND CONTRACT TYPES SPECIAL CONTRACTING METHODS Master Agreement for... soliciting offers, may issue a written job order to a contractor that has previously executed a master...

  12. Phonon Confinement Effect in TiO2 Nanoparticles as Thermosensor Materials

    DTIC Science & Technology

    2018-01-24

    TiO2 or ZnO nanoparticles (NPs) have a very strong finite-size dependency in their Raman spectra or photoluminescence (PL) spectra due to the phonon...spectrometers were used to establish the particle size versus the Raman/PL peak position master curves. Systematic isothermal and temperature- dependent heat...Thermosensor Materials", Workshop on Time- Dependent Temperature Measurements in Energy Release Processes, Chicago, IL, 2012. 11 3) Ashish Kumar Mishra

  13. Determination of Tafel Constants in Nonlinear Polarization Curves.

    DTIC Science & Technology

    1987-12-01

    resulted in difficulty in determining the Tafel constants from such plots. A FORTRAN based program involving numerical differentiation techniques was...MASTER OF SCIENCE IN MECHANICAL ENGINEERING from the NAVAL POSTGRADUATE SCHOOL December 1987 Auho:Th as Edr L~oughlin Approved by: J erkins hesis Advisor...Inthony J.f Healey, Chai man, Departm o Mhnical E gineering ’ Gordon E. Schacher Dean of Science and Engineering 21 ABSTRACT The presence of non-linear

  14. Evaluation of accuracy and precision of a smartphone based automated parasite egg counting system in comparison to the McMaster and Mini-FLOTAC methods.

    PubMed

    Scare, J A; Slusarewicz, P; Noel, M L; Wielgus, K M; Nielsen, M K

    2017-11-30

    Fecal egg counts are emphasized for guiding equine helminth parasite control regimens due to the rise of anthelmintic resistance. This, however, poses further challenges, since egg counting results are prone to issues such as operator dependency, method variability, equipment requirements, and time commitment. The use of image analysis software for performing fecal egg counts is promoted in recent studies to reduce the operator dependency associated with manual counts. In an attempt to remove operator dependency associated with current methods, we developed a diagnostic system that utilizes a smartphone and employs image analysis to generate automated egg counts. The aims of this study were (1) to determine precision of the first smartphone prototype, the modified McMaster and ImageJ; (2) to determine precision, accuracy, sensitivity, and specificity of the second smartphone prototype, the modified McMaster, and Mini-FLOTAC techniques. Repeated counts on fecal samples naturally infected with equine strongyle eggs were performed using each technique to evaluate precision. Triplicate counts on 36 egg count negative samples and 36 samples spiked with strongyle eggs at 5, 50, 500, and 1000 eggs per gram were performed using a second smartphone system prototype, Mini-FLOTAC, and McMaster to determine technique accuracy. Precision across the techniques was evaluated using the coefficient of variation. In regards to the first aim of the study, the McMaster technique performed with significantly less variance than the first smartphone prototype and ImageJ (p<0.0001). The smartphone and ImageJ performed with equal variance. In regards to the second aim of the study, the second smartphone system prototype had significantly better precision than the McMaster (p<0.0001) and Mini-FLOTAC (p<0.0001) methods, and the Mini-FLOTAC was significantly more precise than the McMaster (p=0.0228). Mean accuracies for the Mini-FLOTAC, McMaster, and smartphone system were 64.51%, 21.67%, and 32.53%, respectively. The Mini-FLOTAC was significantly more accurate than the McMaster (p<0.0001) and the smartphone system (p<0.0001), while the smartphone and McMaster counts did not have statistically different accuracies. Overall, the smartphone system compared favorably to manual methods with regards to precision, and reasonably with regards to accuracy. With further refinement, this system could become useful in veterinary practice. Copyright © 2017 Elsevier B.V. All rights reserved.

  15. A Comparison of the Sensitivity and Fecal Egg Counts of the McMaster Egg Counting and Kato-Katz Thick Smear Methods for Soil-Transmitted Helminths

    PubMed Central

    Levecke, Bruno; Behnke, Jerzy M.; Ajjampur, Sitara S. R.; Albonico, Marco; Ame, Shaali M.; Charlier, Johannes; Geiger, Stefan M.; Hoa, Nguyen T. V.; Kamwa Ngassam, Romuald I.; Kotze, Andrew C.; McCarthy, James S.; Montresor, Antonio; Periago, Maria V.; Roy, Sheela; Tchuem Tchuenté, Louis-Albert; Thach, D. T. C.; Vercruysse, Jozef

    2011-01-01

    Background The Kato-Katz thick smear (Kato-Katz) is the diagnostic method recommended for monitoring large-scale treatment programs implemented for the control of soil-transmitted helminths (STH) in public health, yet it is difficult to standardize. A promising alternative is the McMaster egg counting method (McMaster), commonly used in veterinary parasitology, but rarely so for the detection of STH in human stool. Methodology/Principal Findings The Kato-Katz and McMaster methods were compared for the detection of STH in 1,543 subjects resident in five countries across Africa, Asia and South America. The consistency of the performance of both methods in different trials, the validity of the fixed multiplication factor employed in the Kato-Katz method and the accuracy of these methods for estimating ‘true’ drug efficacies were assessed. The Kato-Katz method detected significantly more Ascaris lumbricoides infections (88.1% vs. 75.6%, p<0.001), whereas the difference in sensitivity between the two methods was non-significant for hookworm (78.3% vs. 72.4%) and Trichuris trichiura (82.6% vs. 80.3%). The sensitivity of the methods varied significantly across trials and magnitude of fecal egg counts (FEC). Quantitative comparison revealed a significant correlation (Rs >0.32) in FEC between both methods, and indicated no significant difference in FEC, except for A. lumbricoides, where the Kato-Katz resulted in significantly higher FEC (14,197 eggs per gram of stool (EPG) vs. 5,982 EPG). For the Kato-Katz, the fixed multiplication factor resulted in significantly higher FEC than the multiplication factor adjusted for mass of feces examined for A. lumbricoides (16,538 EPG vs. 15,396 EPG) and T. trichiura (1,490 EPG vs. 1,363 EPG), but not for hookworm. The McMaster provided more accurate efficacy results (absolute difference to ‘true’ drug efficacy: 1.7% vs. 4.5%). Conclusions/Significance The McMaster is an alternative method for monitoring large-scale treatment programs. It is a robust (accurate multiplication factor) and accurate (reliable efficacy results) method, which can be easily standardized. PMID:21695104

  16. Comparison of commercial RNA extraction kits and qPCR master mixes for studying gene expression in small biopsy tissue samples from the equine gastric epithelium.

    PubMed

    Tesena, Parichart; Korchunjit, Wasamon; Taylor, Jane; Wongtawan, Tuempong

    2017-01-01

    Gastric tissue biopsy and gene expression analysis are important tools for disease diagnosis and study of the physiology of the equine stomach. However, RNA extraction from gastric biopsy samples is a complex procedure because the samples contain low quantities of RNA and are contaminated with mucous protein and bacterial flora. The objectives of these studies were to compare the performance of RNA extraction methods and to investigate the sensitivity of commercial qPCR master mixes for gene expression analysis of gastric biopsy samples. Three commercial RNA extraction methods (TRIzol ™ , GENEzol ™ and MiniPrep ™ ) and four qPCR master mixes with SYBR ® green (qPCRBIO, KAPA, QuantiNova, and PerfeCTa) were compared. RNA qualification and quantitation were compared. Real-time PCR was used to compare qPCR master mixes. The results revealed that TRIzol and GENEzol obtained significantly higher yield of RNA (P<0.01) but that TRIzol had the highest contamination of protein and DNA (P<0.05). Conversely, MiniPrep resulting in a significantly higher purification of RNA (P<0.05) but provided the lowest yield of RNA (P<0.01). For PCR master mixes, KAPA was significantly (P<0.05) more sensitive than other qPCR kits for all amounts of DNA template, particularly at the lowest amount of cDNA. In conclusion, GENEzol is the best method to obtain a high RNA yield and purification and it is more cost-effective than the others as well. Regarding the qPCR master mixes, KAPA SYBR qPCR Master Mix (2x) Universal is superior to the other tested master mixes for studying gene expression in equine gastric biopsies.

  17. 48 CFR 217.7103-2 - Period of agreement.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ....7103-2 Section 217.7103-2 Federal Acquisition Regulations System DEFENSE ACQUISITION REGULATIONS SYSTEM, DEPARTMENT OF DEFENSE CONTRACTING METHODS AND CONTRACT TYPES SPECIAL CONTRACTING METHODS Master Agreement for.... (c) Cancellation of a master agreement does not affect the rights and liabilities under any job order...

  18. 48 CFR 217.7103-2 - Period of agreement.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ....7103-2 Section 217.7103-2 Federal Acquisition Regulations System DEFENSE ACQUISITION REGULATIONS SYSTEM, DEPARTMENT OF DEFENSE CONTRACTING METHODS AND CONTRACT TYPES SPECIAL CONTRACTING METHODS Master Agreement for.... (c) Cancellation of a master agreement does not affect the rights and liabilities under any job order...

  19. 48 CFR 217.7103-2 - Period of agreement.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ....7103-2 Section 217.7103-2 Federal Acquisition Regulations System DEFENSE ACQUISITION REGULATIONS SYSTEM, DEPARTMENT OF DEFENSE CONTRACTING METHODS AND CONTRACT TYPES SPECIAL CONTRACTING METHODS Master Agreement for.... (c) Cancellation of a master agreement does not affect the rights and liabilities under any job order...

  20. 48 CFR 217.7103-2 - Period of agreement.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ....7103-2 Section 217.7103-2 Federal Acquisition Regulations System DEFENSE ACQUISITION REGULATIONS SYSTEM, DEPARTMENT OF DEFENSE CONTRACTING METHODS AND CONTRACT TYPES SPECIAL CONTRACTING METHODS Master Agreement for.... (c) Cancellation of a master agreement does not affect the rights and liabilities under any job order...

  1. 48 CFR 217.7103-2 - Period of agreement.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ....7103-2 Section 217.7103-2 Federal Acquisition Regulations System DEFENSE ACQUISITION REGULATIONS SYSTEM, DEPARTMENT OF DEFENSE CONTRACTING METHODS AND CONTRACT TYPES SPECIAL CONTRACTING METHODS Master Agreement for.... (c) Cancellation of a master agreement does not affect the rights and liabilities under any job order...

  2. Conservatoire Students' Experiences and Perceptions of Instrument-Specific Master Classes

    ERIC Educational Resources Information Center

    Long, Marion; Creech, Andrea; Gaunt, Helena; Hallam, Susan

    2014-01-01

    Historically, in the professional training of musicians, the master-apprentice model has played a central role in instilling the methods and values of the discipline, contributing to the rigorous formation of talent. Expert professional musicians advocate that certain thinking skills can be modelled through the master-apprentice model, yet its…

  3. Method of fabricating a 3-dimensional tool master

    DOEpatents

    Bonivert, William D.; Hachman, John T.

    2002-01-01

    The invention is a method for the fabrication of an imprint tool master. The process begins with a metallic substrate. A layer of photoresist is placed onto the metallic substrate and a image pattern mask is then aligned to the mask. The mask pattern has opaque portions that block exposure light and "open" or transparent portions which transmit exposure light. The photoresist layer is then exposed to light transmitted through the "open" portions of the first image pattern mask and the mask is then removed. A second layer of photoresist then can be placed onto the first photoresist layer and a second image pattern mask may be placed on the second layer of photoresist. The second layer of photoresist is exposed to light, as before, and the second mask removed. The photoresist layers are developed simultaneously to produce a multi-level master mandrel upon which a conductive film is formed. A tool master can now be formed onto the conductive film. An imprint tool is then produced from the tool master. In one embodiment, nickel is electroplated onto the tool master to produce a three-dimensional imprint tool.

  4. Modified flotation method with the use of Percoll for the detection of Isospora suis oocysts in suckling piglet faeces.

    PubMed

    Karamon, Jacek; Ziomko, Irena; Cencek, Tomasz; Sroka, Jacek

    2008-10-01

    The modification of flotation method for the examination of diarrhoeic piglet faeces for the detection of Isospora suis oocysts was elaborated. The method was based on removing fractions of fat from the sample of faeces by centrifugation with a 25% Percoll solution. The investigations were carried out in comparison to the McMaster method. From five variants of the Percoll flotation method, the best results were obtained when 2ml of flotation liquid per 1g of faeces were used. The limit of detection in the Percoll flotation method was 160 oocysts per 1g, and was better than with the McMaster method. The efficacy of the modified method was confirmed by results obtained in the examination of the I. suis infected piglets. From all faecal samples, positive samples in the Percoll flotation method were double the results than that of the routine method. Oocysts were first detected by the Percoll flotation method on day 4 post-invasion, i.e. one-day earlier than with the McMaster method. During the experiment (except for 3 days), the extensity of I. suis invasion in the litter examined by the Percoll flotation method was higher than that with the McMaster method. The obtained results show that the modified flotation method with the use of Percoll could be applied in the diagnostics of suckling piglet isosporosis.

  5. Examining the Value Master's and PhD Students Place on Various Instructional Methods in Educational Leadership Preparation

    ERIC Educational Resources Information Center

    Gordon, Stephen P.; Oliver, John

    2015-01-01

    The purpose of this study was to determine the value that graduate students place on different types of instructional methods used by professors in educational leadership preparation programs, and to determine if master's and doctoral students place different values on different instructional methods. The participants included 87 graduate…

  6. Method of Controlling Steering of a Ground Vehicle

    NASA Technical Reports Server (NTRS)

    Guo, Raymond (Inventor); Atluri, Venkata Prasad (Inventor); Bluethmann, William J. (Inventor); Lee, Chunhao J. (Inventor); Vitale, Robert L. (Inventor); Dawson, Andrew D. (Inventor)

    2016-01-01

    A method of controlling steering of a vehicle through setting wheel angles of a plurality of modular electronic corner assemblies (eModules) is provided. The method includes receiving a driving mode selected from a mode selection menu. A position of a steering input device is determined in a master controller. A velocity of the vehicle is determined, in the master controller, when the determined position of the steering input device is near center. A drive mode request corresponding to the selected driving mode to the plurality of steering controllers is transmitted to the master controller. A required steering angle of each of the plurality of eModules is determined, in the master controller, as a function of the determined position of the steering input device, the determined velocity of the vehicle, and the selected first driving mode. The eModules are set to the respective determined steering angles.

  7. Finite-time master-slave synchronization and parameter identification for uncertain Lurie systems.

    PubMed

    Wang, Tianbo; Zhao, Shouwei; Zhou, Wuneng; Yu, Weiqin

    2014-07-01

    This paper investigates the finite-time master-slave synchronization and parameter identification problem for uncertain Lurie systems based on the finite-time stability theory and the adaptive control method. The finite-time master-slave synchronization means that the state of a slave system follows with that of a master system in finite time, which is more reasonable than the asymptotical synchronization in applications. The uncertainties include the unknown parameters and noise disturbances. An adaptive controller and update laws which ensures the synchronization and parameter identification to be realized in finite time are constructed. Finally, two numerical examples are given to show the effectiveness of the proposed method. Copyright © 2014 ISA. Published by Elsevier Ltd. All rights reserved.

  8. System and method for inventorying multiple remote objects

    DOEpatents

    Carrender, Curtis L.; Gilbert, Ronald W.

    2007-10-23

    A system and method of inventorying multiple objects utilizing a multi-level or a chained radio frequency identification system. The system includes a master tag and a plurality of upper level tags and lower level tags associated with respective objects. The upper and lower level tags communicate with each other and the master tag so that reading of the master tag reveals the presence and absence of upper and lower level tags. In the chained RF system, the upper and lower level tags communicate locally with each other in a manner so that more remote tags that are out of range of some of the upper and lower level tags have their information relayed through adjacent tags to the master tag and thence to a controller.

  9. System and method for inventorying multiple remote objects

    DOEpatents

    Carrender, Curtis L [Morgan Hill, CA; Gilbert, Ronald W [Morgan Hill, CA

    2009-12-29

    A system and method of inventorying multiple objects utilizing a multi-level or a chained radio frequency identification system. The system includes a master tag and a plurality of upper level tags and lower level tags associated with respective objects. The upper and lower level tags communicate with each other and the master tag so that reading of the master tag reveals the presence and absence of upper and lower level tags. In the chained RF system, the upper and lower level tags communicate locally with each other in a manner so that more remote tags that are out of range of some of the upper and lower level tags have their information relayed through adjacent tags to the master tag and thence to a controller.

  10. Operator Approach to the Master Equation for the One-Step Process

    NASA Astrophysics Data System (ADS)

    Hnatič, M.; Eferina, E. G.; Korolkova, A. V.; Kulyabov, D. S.; Sevastyanov, L. A.

    2016-02-01

    Background. Presentation of the probability as an intrinsic property of the nature leads researchers to switch from deterministic to stochastic description of the phenomena. The kinetics of the interaction has recently attracted attention because it often occurs in the physical, chemical, technical, biological, environmental, economic, and sociological systems. However, there are no general methods for the direct study of this equation. The expansion of the equation in a formal Taylor series (the so called Kramers-Moyal's expansion) is used in the procedure of stochastization of one-step processes. Purpose. However, this does not eliminate the need for the study of the master equation. Method. It is proposed to use quantum field perturbation theory for the statistical systems (the so-called Doi method). Results: This work is a methodological material that describes the principles of master equation solution based on quantum field perturbation theory methods. The characteristic property of the work is that it is intelligible for non-specialists in quantum field theory. Conclusions: We show the full equivalence of the operator and combinatorial methods of obtaining and study of the one-step process master equation.

  11. Method and apparatus for connecting finite element meshes and performing simulations therewith

    DOEpatents

    Dohrmann, Clark R.; Key, Samuel W.; Heinstein, Martin W.

    2003-05-06

    The present invention provides a method of connecting dissimilar finite element meshes. A first mesh, designated the master mesh, and a second mesh, designated the slave mesh, each have interface surfaces proximal the other. Each interface surface has a corresponding interface mesh comprising a plurality of interface nodes. Each slave interface node is assigned new coordinates locating the interface node on the interface surface of the master mesh. The slave interface surface is further redefined to be the projection of the slave interface mesh onto the master interface surface.

  12. Fatigue behavior of a cross-ply ceramic matrix composite subjected to tension-tension cycling with hold time. Master`s thesis

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Grant, S.A.

    This study was carried out to investigate the elevated temperature behavior of the SiC-MAS5 cross- ply (O/9O)4S ceramic matrix composite manufactured by Corning Inc. to fatigue with loading waveforms that combine the characteristics of stress rupture and high cycle fatigue. The test results were compiled in the form of S-N (cycles to failure), S-T (exposure time versus cycles to failure), S-S (energy exposure versus cycles to failure), normalized modulus degradation, strain progression, and hysteresis loop progression. From the mechanical behavior demonstrated by these curves, relationships between the effect of the environment and loading waveform were developed. In addition, a post-mortemmore » SEM analysis of the fracture surface was conducted and the results compared to the mechanical behavior.« less

  13. Point-to-point connectivity prediction in porous media using percolation theory

    NASA Astrophysics Data System (ADS)

    Tavagh-Mohammadi, Behnam; Masihi, Mohsen; Ganjeh-Ghazvini, Mostafa

    2016-10-01

    The connectivity between two points in porous media is important for evaluating hydrocarbon recovery in underground reservoirs or toxic migration in waste disposal. For example, the connectivity between a producer and an injector in a hydrocarbon reservoir impact the fluid dispersion throughout the system. The conventional approach, flow simulation, is computationally very expensive and time consuming. Alternative method employs percolation theory. Classical percolation approach investigates the connectivity between two lines (representing the wells) in 2D cross sectional models whereas we look for the connectivity between two points (representing the wells) in 2D aerial models. In this study, site percolation is used to determine the fraction of permeable regions connected between two cells at various occupancy probabilities and system sizes. The master curves of mean connectivity and its uncertainty are then generated by finite size scaling. The results help to predict well-to-well connectivity without need to any further simulation.

  14. The effects of physical aging at elevated temperatures on the viscoelastic creep on IM7/K3B

    NASA Technical Reports Server (NTRS)

    Gates, Thomas S.; Feldman, Mark

    1994-01-01

    Physical aging at elevated temperature of the advanced composite IM7/K3B was investigated through the use of creep compliance tests. Testing consisted of short term isothermal, creep/recovery with the creep segments performed at constant load. The matrix dominated transverse tensile and in-plane shear behavior were measured at temperatures ranging from 200 to 230 C. Through the use of time based shifting procedures, the aging shift factors, shift rates and momentary master curve parameters were found at each temperature. These material parameters were used as input to a predictive methodology, which was based upon effective time theory and linear viscoelasticity combined with classical lamination theory. Long term creep compliance test data was compared to predictions to verify the method. The model was then used to predict the long term creep behavior for several general laminates.

  15. [Simulation in surgical training].

    PubMed

    Nabavi, A; Schipper, J

    2017-01-01

    Patient safety during operations hinges on the surgeon's skills and abilities. However, surgical training has come under a variety of restrictions. To acquire dexterity with decreasingly "simple" cases, within the legislative time constraints and increasing expectations for surgical results is the future challenge. Are there alternatives to traditional master-apprentice learning? A literature review and analysis of the development, implementation, and evaluation of surgical simulation are presented. Simulation, using a variety of methods, most important physical and virtual (computer-generated) models, provides a safe environment to practice basic and advanced skills without endangering patients. These environments have specific strengths and weaknesses. Simulations can only serve to decrease the slope of learning curves, but cannot be a substitute for the real situation. Thus, they have to be an integral part of a comprehensive training curriculum. Our surgical societies have to take up that challenge to ensure the training of future generations.

  16. Diagnostic Profiles: A Standard Setting Method for Use with a Cognitive Diagnostic Model

    ERIC Educational Resources Information Center

    Skaggs, Gary; Hein, Serge F.; Wilkins, Jesse L. M.

    2016-01-01

    This article introduces the Diagnostic Profiles (DP) standard setting method for setting a performance standard on a test developed from a cognitive diagnostic model (CDM), the outcome of which is a profile of mastered and not-mastered skills or attributes rather than a single test score. In the DP method, the key judgment task for panelists is a…

  17. Educator Perspectives on the Use of Alternative Assessment Methods within Taught Masters Programmes: An Exploratory Study Using Activity Theory and Q Methodology

    ERIC Educational Resources Information Center

    Deignan, Tim; Brown, Sally

    2016-01-01

    This article reports on an exploratory two-stage sequential mixed methods research study that investigated the views of university educators on the introduction of assessment methods other than essays, exams and dissertations within taught Masters programmes. In the first stage, interviews were conducted internationally with 45 participants and…

  18. A Comparative Study of Four Methods for the Detection of Nematode Eggs and Large Protozoan Cysts in Mandrill Faecal Material.

    PubMed

    Pouillevet, Hanae; Dibakou, Serge-Ely; Ngoubangoye, Barthélémy; Poirotte, Clémence; Charpentier, Marie J E

    2017-01-01

    Coproscopical methods like sedimentation and flotation techniques are widely used in the field for studying simian gastrointestinal parasites. Four parasites of known zoonotic potential were studied in a free-ranging, non-provisioned population of mandrills (Mandrillus sphinx): 2 nematodes (Necatoramericanus/Oesophagostomum sp. complex and Strongyloides sp.) and 2 protozoan species (Balantidium coli and Entamoeba coli). Different coproscopical techniques are available but they are rarely compared to evaluate their efficiency to retrieve parasites. In this study 4 different field-friendly methods were compared. A sedimentation method and 3 different McMaster methods (using sugar, salt, and zinc sulphate solutions) were performed on 47 faecal samples collected from different individuals of both sexes and all ages. First, we show that McMaster flotation methods are appropriate to detect and thus quantify large protozoan cysts. Second, zinc sulphate McMaster flotation allows the retrieval of a higher number of parasite taxa compared to the other 3 methods. This method further shows the highest probability to detect each of the studied parasite taxa. Altogether our results show that zinc sulphate McMaster flotation appears to be the best technique to use when studying nematodes and large protozoa. © 2017 S. Karger AG, Basel.

  19. Compilation of Abstracts of Theses Submitted by Candidates for Degrees.

    DTIC Science & Technology

    1982-05-01

    which either ti- tanium or aluminum tubes are used in the heat exchanges . Master of Science in Advisor: R. H. Nunn Mechanical Engineering Department... Testing in an Inert Environment Holihan, R. G., Jr. Investigation of Heat Transfer in 208 LCDR, USN Straight and Curved Rectangular Ducts for Laminar...for c-ft materials fatigue testing . The system uses an HP-9835 Desktop . .tnr, an HP-2240A Measurement and Control Processor and a Materials P System

  20. On the temperature independence of statistical model parameters for cleavage fracture in ferritic steels

    NASA Astrophysics Data System (ADS)

    Qian, Guian; Lei, Wei-Sheng; Niffenegger, M.; González-Albuixech, V. F.

    2018-04-01

    The work relates to the effect of temperature on the model parameters in local approaches (LAs) to cleavage fracture. According to a recently developed LA model, the physical consensus of plastic deformation being a prerequisite to cleavage fracture enforces any LA model of cleavage fracture to observe initial yielding of a volume element as its threshold stress state to incur cleavage fracture in addition to the conventional practice of confining the fracture process zone within the plastic deformation zone. The physical consistency of the new LA model to the basic LA methodology and the differences between the new LA model and other existing models are interpreted. Then this new LA model is adopted to investigate the temperature dependence of LA model parameters using circumferentially notched round tensile specimens. With the published strength data as input, finite element (FE) calculation is conducted for elastic-perfectly plastic deformation and the realistic elastic-plastic hardening, respectively, to provide stress distributions for model calibration. The calibration results in temperature independent model parameters. This leads to the establishment of a 'master curve' characteristic to synchronise the correlation between the nominal strength and the corresponding cleavage fracture probability at different temperatures. This 'master curve' behaviour is verified by strength data from three different steels, providing a new path to calculate cleavage fracture probability with significantly reduced FE efforts.

  1. Viscosity scaling in concentrated dispersions and its impact on colloidal aggregation.

    PubMed

    Nicoud, Lucrèce; Lattuada, Marco; Lazzari, Stefano; Morbidelli, Massimo

    2015-10-07

    Gaining fundamental knowledge about diffusion in crowded environments is of great relevance in a variety of research fields, including reaction engineering, biology, pharmacy and colloid science. In this work, we determine the effective viscosity experienced by a spherical tracer particle immersed in a concentrated colloidal dispersion by means of Brownian dynamics simulations. We characterize how the effective viscosity increases from the solvent viscosity for small tracer particles to the macroscopic viscosity of the dispersion when large tracer particles are employed. Our results show that the crossover between these two regimes occurs at a tracer particle size comparable to the host particle size. In addition, it is found that data points obtained in various host dispersions collapse on one master curve when the normalized effective viscosity is plotted as a function of the ratio between the tracer particle size and the mean host particle size. In particular, this master curve was obtained by varying the volume fraction, the average size and the polydispersity of the host particle distribution. Finally, we extend these results to determine the size dependent effective viscosity experienced by a fractal cluster in a concentrated colloidal system undergoing aggregation. We include this scaling of the effective viscosity in classical aggregation kernels, and we quantify its impact on the kinetics of aggregate growth as well as on the shape of the aggregate distribution by means of population balance equation calculations.

  2. Performance Comparison of Al-Ti Master Alloys with Different Microstructures in Grain Refinement of Commercial Purity Aluminum.

    PubMed

    Ding, Wanwu; Xia, Tiandong; Zhao, Wenjun

    2014-05-07

    Three types of Al-5Ti master alloys were synthesized by a method of thermal explosion reaction in pure molten aluminum. Performance comparison of Al-5Ti master alloy in grain refinement of commercial purity Al with different additions (0.6%, 1.0%, 1.6%, 2.0%, and 3.0%) and holding time (10, 30, 60 and 120 min) were investigated. The results show that Al-5Ti master alloy with blocky TiAl₃ particles clearly has better refining efficiency than the master alloy with mixed TiAl₃ particles and the master alloy with needle-like TiAl₃ particles. The structures of master alloys, differing by sizes, morphologies and quantities of TiAl₃ crystals, were found to affect the pattern of the grain refining properties with the holding time. The grain refinement effect was revealed to reduce markedly for master alloys with needle-like TiAl₃ crystals and to show the further significant improvement at a longer holding time for the master alloy containing both larger needle-like and blocky TiAl₃ particles. For the master alloy with finer blocky particles, the grain refining effect did not obviously decrease during the whole studied range of the holding time.

  3. Near-peer mentorship for undergraduate training in Ugandan medical schools: views of undergraduate students

    PubMed Central

    Rukundo, Godfrey Zari; Burani, Aluonzi; Kasozi, Jannat; Kirimuhuzya, Claude; Odongo, Charles; Mwesigwa, Catherine; Byona, Wycliff; Kiguli, Sarah

    2016-01-01

    Introduction Masters Students are major stakeholders in undergraduate medical education but their contribution has not been documented in Uganda. The aim of the study was to explore and document views and experiences of undergraduate students regarding the role of masters students as educators in four Ugandan medical schools. Methods This was a cross-sectional descriptive study using qualitative data collection methods. Eight Focus Group Discussions were conducted among eighty one selected preclinical and clinical students in the consortium of four Ugandan medical schools: Mbarara University of Science and Technology, Makerere College of Health Sciences, Gulu University and Kampala International University, Western Campus. Data analysis was done using thematic analysis. Participants’ privacy and confidentiality were respected and participant identifiers were not included in data analysis. Results Undergraduate students from all the medical schools viewed the involvement of master's students as very important. Frequent contact between masters and undergraduate students was reported as an important factor in undergraduate students’ motivation and learning. Despite the useful contribution, master’ students face numerous challenges like heavy workload and conflicting priorities. Conclusion According to undergraduate students in Ugandan medical schools, involvement of master's students in the teaching and learning of undergraduate students is both useful and challenging to masters and undergraduate students. Masters students provide peer mentorship to the undergraduate students. The senior educators are still needed to do their work and also to support the master's students in their teaching role. PMID:27347289

  4. Near room temperature magnetocaloric properties and the universal curve of MnCoGe1-xCux

    NASA Astrophysics Data System (ADS)

    Si, Xiaodong; Liu, Yongsheng; Lu, Xiaofei; Shen, Yulong; Wang, Wenli; Yu, Wenying; Zhou, Tao; Gao, Tian

    2017-05-01

    Intermetallic compounds based on MnCoGe have drawn attention due to the coupled magnetic and structural transformations and the large magnetocaloric entropy. Here, we provide a systematic comparison of experimental data under different magnetic fields with magnetic and the magnetocaloric properties. The ferromagnetic transition temperature (TC) increases from 353.4(6) K for x = 0.01 to 363.4(4) K for x = 0.04 with increasing nominal copper content. The maximum magnetic entropy change |ΔSM| in a magnetic field change of 5 T is found to be 18.3(2) J/(kg K) with a large relative cooling power (RCP) value of 292.5(4) J/kg for x = 0.01, revealing that the present system can provide an acceptable magnetocaloric effect at a cheaper price for magnetic refrigeration materials. Making attempt to contrast a master curve for the present system, we find the experimental values of magnetic field dependence of the magnetic entropy change are consistent with a phenomenological universal curve.

  5. Fracture-Toughness Analysis in Transition-Temperature Region of Three American Petroleum Institute X70 and X80 Pipeline Steels

    NASA Astrophysics Data System (ADS)

    Shin, Sang Yong; Woo, Kuk Je; Hwang, Byoungchul; Kim, Sangho; Lee, Sunghak

    2009-04-01

    The fracture toughness in the transition-temperature region of three American Petroleum Institute (API) X70 and X80 pipeline steels was analyzed in accordance with the American Society for Testing and Materials (ASTM) E1921-05 standard test method. The elastic-plastic cleavage fracture toughness ( K Jc ) was determined by three-point bend tests, using precracked Charpy V-notch (PCVN) specimens; the measured K Jc values were then interpreted by the three-parameter Weibull distribution. The fracture-toughness test results indicated that the master curve and the 98 pct confidence curves explained the variation in the measured fracture toughness well. The reference temperatures obtained from the fracture-toughness test and index temperatures obtained from the Charpy impact test were lowest in the X70 steel rolled in the two-phase region, because this steel had smaller effective grains and the lowest volume fraction of hard phases. In this steel, few hard phases led to a higher resistance to cleavage crack initiation, and the smaller effective grain size led to a higher possibility of crack arrest, thereby resulting in the best overall fracture properties. Measured reference temperatures were then comparatively analyzed with the index temperatures obtained from the Charpy impact test, and the effects of microstructures on these temperatures were discussed.

  6. Viscoelastic flow past mono- and bidisperse random arrays of cylinders: flow resistance, topology and normal stress distribution.

    PubMed

    De, S; Kuipers, J A M; Peters, E A J F; Padding, J T

    2017-12-13

    We investigate creeping viscoelastic fluid flow through two-dimensional porous media consisting of random arrangements of monodisperse and bidisperse cylinders, using our finite volume-immersed boundary method introduced in S. De, et al., J. Non-Newtonian Fluid Mech., 2016, 232, 67-76. The viscoelastic fluid is modeled with a FENE-P model. The simulations show an increased flow resistance with increase in flow rate, even though the bulk response of the fluid to shear flow is shear thinning. We show that if the square root of the permeability is chosen as the characteristic length scale in the determination of the dimensionless Deborah number (De), then all flow resistance curves collapse to a single master curve, irrespective of the pore geometry. Our study reveals how viscoelastic stresses and flow topologies (rotation, shear and extension) are distributed through the porous media, and how they evolve with increasing De. We correlate the local viscoelastic first normal stress differences with the local flow topology and show that the largest normal stress differences are located in shear flow dominated regions and not in extensional flow dominated regions at higher viscoelasticity. The study shows that normal stress differences in shear flow regions may play a crucial role in the increase of flow resistance for viscoelastic flow through such porous media.

  7. Experiencing Research Firsthand: The "unClassroom" Experiential Learning Approach to Teaching Research Methods in an LIS Master's Program

    ERIC Educational Resources Information Center

    Mandel, Lauren H.

    2017-01-01

    Research methods education in LIS master's degree programs is facing several difficult questions: should a methods course be required, what content should be taught in that course, and what is the most effective mechanism for teaching that content. There is little consensus about what should be taught or how, but the American Library Association,…

  8. English in Eastern Ethiopia Is Learnt; Not Mastered

    ERIC Educational Resources Information Center

    Jha, Sanjay Kumar

    2013-01-01

    English Language Teaching (ELT) has undergone immense changes over the years in terms of using different methods, but none of the methods till this date have proved what they had proclaimed. The paper believes in the hypothesis that learning is "understanding" the linguistic components of a language, whereas mastering is the part of…

  9. Consumer holographic read-only memory reader with mastering and replication technology.

    PubMed

    Chuang, Ernest; Curtis, Kevin; Yang, Yunping; Hill, Adrian

    2006-04-15

    What is believed to be a novel holographic design for read-only memory systems allows a compact low-cost consumer drive within a 10 mm drive height, using a lensless phase conjugate readout and a combination of polytopic and angle multiplexing. A two-step mastering method enables production of high-efficiency holographic masters, and fast replication is possible by using only a series of plane-wave illuminations. Mastering and replication techniques are verified experimentally with an array of 125 holograms with no measured bit errors.

  10. Analysis of the accuracy and precision of the McMaster method in detection of the eggs of Toxocara and Trichuris species (Nematoda) in dog faeces.

    PubMed

    Kochanowski, Maciej; Dabrowska, Joanna; Karamon, Jacek; Cencek, Tomasz; Osiński, Zbigniew

    2013-07-01

    The aim of this study was to determine the accuracy and precision of McMaster method with Raynaud's modification in the detection of the eggs of the nematodes Toxocara canis (Werner, 1782) and Trichuris ovis (Abildgaard, 1795) in faeces of dogs. Four variants of McMaster method were used for counting: in one grid, two grids, the whole McMaster chamber and flotation in the tube. One hundred sixty samples were prepared from dog faeces (20 repetitions for each egg quantity) containing 15, 25, 50, 100, 150, 200, 250 and 300 eggs of T. canis and T. ovis in 1 g of faeces. To compare the influence of kind of faeces on the results, samples of dog faeces were enriched at the same levels with the eggs of another nematode, Ascaris suum Goeze, 1782. In addition, 160 samples of pig faeces were prepared and enriched only with A. suum eggs in the same way. The highest limit of detection (the lowest level of eggs that were detected in at least 50% of repetitions) in all McMaster chamber variants were obtained for T. canis eggs (25-250 eggs/g faeces). In the variant with flotation in the tube, the highest limit of detection was obtained for T. ovis eggs (100 eggs/g). The best results of the limit of detection, sensitivity and the lowest coefficients of variation were obtained with the use of the whole McMaster chamber variant. There was no significant impact of properties of faeces on the obtained results. Multiplication factors for the whole chamber were calculated on the basis of the transformed equation of the regression line, illustrating the relationship between the number of detected eggs and that of the eggs added to the'sample. Multiplication factors calculated for T. canis and T. ovis eggs were higher than those expected using McMaster method with Raynaud modification.

  11. System and method for merging clusters of wireless nodes in a wireless network

    DOEpatents

    Budampati, Ramakrishna S [Maple Grove, MN; Gonia, Patrick S [Maplewood, MN; Kolavennu, Soumitri N [Blaine, MN; Mahasenan, Arun V [Kerala, IN

    2012-05-29

    A system includes a first cluster having multiple first wireless nodes. One first node is configured to act as a first cluster master, and other first nodes are configured to receive time synchronization information provided by the first cluster master. The system also includes a second cluster having one or more second wireless nodes. One second node is configured to act as a second cluster master, and any other second nodes configured to receive time synchronization information provided by the second cluster master. The system further includes a manager configured to merge the clusters into a combined cluster. One of the nodes is configured to act as a single cluster master for the combined cluster, and the other nodes are configured to receive time synchronization information provided by the single cluster master.

  12. The Opinions of Masters Students about the Learning Program in the Field of Teaching Turkish to Foreigners

    ERIC Educational Resources Information Center

    Kilinç, Hasan Huseyin

    2015-01-01

    The purpose of this study is to determine the opinions of Master students about the learning program in the field of teaching Turkish to foreigners. In the study, case study design which is one of the qualitative research methods was used. The population of the study consists of students studying in the Master program with thesis of Teaching…

  13. The Daily Events and Emotions of Master's-Level Family Therapy Trainees in Off-Campus Practicum Settings

    ERIC Educational Resources Information Center

    Edwards, Todd M.; Patterson, Jo Ellen

    2012-01-01

    The Day Reconstruction Method (DRM) was used to assess the daily events and emotions of one program's master's-level family therapy trainees in off-campus practicum settings. This study examines the DRM reports of 35 family therapy trainees in the second year of their master's program in marriage and family therapy. Four themes emerged from the…

  14. Investigation of the History Education Researches in Turkey in Terms of Some Variables (Master's Theses and Dissertations Sample)

    ERIC Educational Resources Information Center

    Elban, Mehmet

    2017-01-01

    The purpose of this research study is to examine the master's theses and dissertations carried out about history education research in Turkey in terms of certain variables. The study is a qualitative research and it used documentary research design as a research method. The population of the research study is the master's theses and dissertations…

  15. Prediction of long-term transverse creep compliance in high-temperature IM7/LaRC-RP46 composites

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Yuan, F.G.; Potter, B.D.

    1994-12-31

    An experimental study is performed which predicts long-term tensile transverse creep compliance of high-temperature IM7/LaRC-RP46 composites from short-term creep and recovery tests. The short-term tests were conducted for various stress levels at various fixed temperatures. Predictive nonlinear viscoelastic model developed by Schapery and experimental procedure were used to predict the long-term results in terms of master curve extrapolated from short-term tests.

  16. On the origins of approximations for stochastic chemical kinetics.

    PubMed

    Haseltine, Eric L; Rawlings, James B

    2005-10-22

    This paper considers the derivation of approximations for stochastic chemical kinetics governed by the discrete master equation. Here, the concepts of (1) partitioning on the basis of fast and slow reactions as opposed to fast and slow species and (2) conditional probability densities are used to derive approximate, partitioned master equations, which are Markovian in nature, from the original master equation. Under different conditions dictated by relaxation time arguments, such approximations give rise to both the equilibrium and hybrid (deterministic or Langevin equations coupled with discrete stochastic simulation) approximations previously reported. In addition, the derivation points out several weaknesses in previous justifications of both the hybrid and equilibrium systems and demonstrates the connection between the original and approximate master equations. Two simple examples illustrate situations in which these two approximate methods are applicable and demonstrate the two methods' efficiencies.

  17. CT protocol management: simplifying the process by using a master protocol concept.

    PubMed

    Szczykutowicz, Timothy P; Bour, Robert K; Rubert, Nicholas; Wendt, Gary; Pozniak, Myron; Ranallo, Frank N

    2015-07-08

    This article explains a method for creating CT protocols for a wide range of patient body sizes and clinical indications, using detailed tube current information from a small set of commonly used protocols. Analytical expressions were created relating CT technical acquisition parameters which can be used to create new CT protocols on a given scanner or customize protocols from one scanner to another. Plots of mA as a function of patient size for specific anatomical regions were generated and used to identify the tube output needs for patients as a function of size for a single master protocol. Tube output data were obtained from the DICOM header of clinical images from our PACS and patient size was measured from CT localizer radiographs under IRB approval. This master protocol was then used to create 11 additional master protocols. The 12 master protocols were further combined to create 39 single and multiphase clinical protocols. Radiologist acceptance rate of exams scanned using the clinical protocols was monitored for 12,857 patients to analyze the effectiveness of the presented protocol management methods using a two-tailed Fisher's exact test. A single routine adult abdominal protocol was used as the master protocol to create 11 additional master abdominal protocols of varying dose and beam energy. Situations in which the maximum tube current would have been exceeded are presented, and the trade-offs between increasing the effective tube output via 1) decreasing pitch, 2) increasing the scan time, or 3) increasing the kV are discussed. Out of 12 master protocols customized across three different scanners, only one had a statistically significant acceptance rate that differed from the scanner it was customized from. The difference, however, was only 1% and was judged to be negligible. All other master protocols differed in acceptance rate insignificantly between scanners. The methodology described in this paper allows a small set of master protocols to be adapted among different clinical indications on a single scanner and among different CT scanners.

  18. Determinations of molecular weight and molecular weight distribution of high polymers by the rheological properties

    NASA Technical Reports Server (NTRS)

    Huang, J. Y.; Hou, T. H.; Tiwari, S. N.

    1989-01-01

    Several methods are reviewed by which the molecular weight (MW) and the molecular weight distribution (MWD) of polymeric material were determined from the rheological properties. A poly(arylene ether) polymer with six different molecular weights was used in this investigation. Experimentally measured MW and MWD were conducted by GPC/LALLS (gel permeation chromatography/low angle laser light scattering), and the rheological properties of the melts were measured by a Rheometric System Four rheometer. It was found that qualitative information of the MW and MWD of these polymers could be derived from the viscoelastic properties, with the methods proposed by Zeichner and Patel, and by Dormier et al., by shifting the master curves of the dynamic storage modulus, G', and the loss modulus, G'', along the frequency axis. Efforts were also made to calculate quantitative profiles of MW and MWD for these polymers from their rheological properties. The technique recently proposed by Wu was evaluated. It was found that satisfactory results could only be obtained for polymers with single modal distribution in the molecular weight.

  19. Elastic modulus and surface tension of a polyurethane rubber in nanometer thick films

    NASA Astrophysics Data System (ADS)

    Zhai, Meiyu; McKenna, Gregory

    2014-03-01

    Estane is a kind of polyurethane with thermodynamically incompatible hard and soft segments. In this study the macro and micro properties of Estane have been characterized and compared. The viscoelastic properties of this material in bulk scale have been determined using dynamic rheometry. Time-temperature superposition was found to be applicable for this material, and a master curve was successfully constructed from the dynamic shear responses of G'(ω) and G''(ω) . Also a novel nano bubble inflation method was used to obtain the creep compliance of the Estane ultrathin films and the results show stiffening in the rubbery region for the Estane over thicknesses ranging from 110nm to 22nm. The dependence of the rubbery stiffening on film thickness is studied and the relative influences of nano confinement and surface tension effect are analyzed using both a direct stress strain analysis and an energy balance method for the membrane. The contributions of surface tension and nano confinement are considered separately. Office of Naval Research under project No.N00014-11-1-0424.

  20. Interpolation and Extrapolation of Creep Rupture Data by the Minimum Commitment Method. Part 3: Analysis of Multiheats

    NASA Technical Reports Server (NTRS)

    Manson, S. S.; Ensign, C. R.

    1978-01-01

    The Minimum Commitment Method was applied to two sets of data for which multiple heat information was available. For one alloy, a 304 stainless steel studied in Japan, data on nine well characterized heats were used, while for a proprietary low alloy carbon steel studied in the United Kingdom data were available on seven heats - in many cases to very long rupture times. For this preliminary study no instability factors were used. It was discovered that heat-to-heat variations would be accounted for by introducing heat identifiers in the form A + B log sigma where sigma is the stress and the constants A and B depend only on the heat. With these identifiers all the data could be collapsed onto a single master curve, even though there was considerable scatter among heats. Using these identifiers together with the average behavior of all heats made possible the determination of an accurate constitutive equation for each individual heat. Two basic approaches are discussed for applying the results of the analysis.

  1. Surgical simulation in orthopaedic skills training.

    PubMed

    Atesok, Kivanc; Mabrey, Jay D; Jazrawi, Laith M; Egol, Kenneth A

    2012-07-01

    Mastering rapidly evolving orthopaedic surgical techniques requires a lengthy period of training. Current work-hour restrictions and cost pressures force trainees to face the challenge of acquiring more complex surgical skills in a shorter amount of time. As a result, alternative methods to improve the surgical skills of orthopaedic trainees outside the operating room have been developed. These methods include hands-on training in a laboratory setting using synthetic bones or cadaver models as well as software tools and computerized simulators that enable trainees to plan and simulate orthopaedic operations in a three-dimensional virtual environment. Laboratory-based training offers potential benefits in the development of basic surgical skills, such as using surgical tools and implants appropriately, achieving competency in procedures that have a steep learning curve, and assessing already acquired skills while minimizing concerns for patient safety, operating room time, and financial constraints. Current evidence supporting the educational advantages of surgical simulation in orthopaedic skills training is limited. Despite this, positive effects on the overall education of orthopaedic residents, and on maintaining the proficiency of practicing orthopaedic surgeons, are anticipated.

  2. Master-slave micromanipulator method

    DOEpatents

    Morimoto, Alan K.; Kozlowski, David M.; Charles, Steven T.; Spalding, James A.

    1999-01-01

    A method based on precision X-Y stages that are stacked. Attached to arms projecting from each X-Y stage are a set of two axis gimbals. Attached to the gimbals is a rod, which provides motion along the axis of the rod and rotation around its axis. A dual-planar apparatus that provides six degrees of freedom of motion precise to within microns of motion. Precision linear stages along with precision linear motors, encoders, and controls provide a robotics system. The motors can be remotized by incorporating a set of bellows on the motors and can be connected through a computer controller that will allow one to be a master and the other one to be a slave. Position information from the master can be used to control the slave. Forces of interaction of the slave with its environment can be reflected back to the motor control of the master to provide a sense of force sensed by the slave. Forces import onto the master by the operator can be fed back into the control of the slave to reduce the forces required to move it.

  3. Torque Measurement of 3-DOF Haptic Master Operated by Controllable Electrorheological Fluid

    NASA Astrophysics Data System (ADS)

    Oh, Jong-Seok; Choi, Seung-Bok; Lee, Yang-Sub

    2015-02-01

    This work presents a torque measurement method of 3-degree-of-freedom (3-DOF) haptic master featuring controllable electrorheological (ER) fluid. In order to reflect the sense of an organ for a surgeon, the ER haptic master which can generate the repulsive torque of an organ is utilized as a remote controller for a surgery robot. Since accurate representation of organ feeling is essential for the success of the robot-assisted surgery, it is indispensable to develop a proper torque measurement method of 3-DOF ER haptic master. After describing the structural configuration of the haptic master, the torque models of ER spherical joint are mathematically derived based on the Bingham model of ER fluid. A new type of haptic device which has pitching, rolling, and yawing motions is then designed and manufactured using a spherical joint mechanism. Subsequently, the field-dependent parameters of the Bingham model are identified and generating repulsive torque according to applied electric field is measured. In addition, in order to verify the effectiveness of the proposed torque model, a comparative work between simulated and measured torques is undertaken.

  4. Kinetic analysis of overlapping multistep thermal decomposition comprising exothermic and endothermic processes: thermolysis of ammonium dinitramide.

    PubMed

    Muravyev, Nikita V; Koga, Nobuyoshi; Meerov, Dmitry B; Pivkina, Alla N

    2017-01-25

    This study focused on kinetic modeling of a specific type of multistep heterogeneous reaction comprising exothermic and endothermic reaction steps, as exemplified by the practical kinetic analysis of the experimental kinetic curves for the thermal decomposition of molten ammonium dinitramide (ADN). It is known that the thermal decomposition of ADN occurs as a consecutive two step mass-loss process comprising the decomposition of ADN and subsequent evaporation/decomposition of in situ generated ammonium nitrate. These reaction steps provide exothermic and endothermic contributions, respectively, to the overall thermal effect. The overall reaction process was deconvoluted into two reaction steps using simultaneously recorded thermogravimetry and differential scanning calorimetry (TG-DSC) curves by considering the different physical meanings of the kinetic data derived from TG and DSC by P value analysis. The kinetic data thus separated into exothermic and endothermic reaction steps were kinetically characterized using kinetic computation methods including isoconversional method, combined kinetic analysis, and master plot method. The overall kinetic behavior was reproduced as the sum of the kinetic equations for each reaction step considering the contributions to the rate data derived from TG and DSC. During reproduction of the kinetic behavior, the kinetic parameters and contributions of each reaction step were optimized using kinetic deconvolution analysis. As a result, the thermal decomposition of ADN was successfully modeled as partially overlapping exothermic and endothermic reaction steps. The logic of the kinetic modeling was critically examined, and the practical usefulness of phenomenological modeling for the thermal decomposition of ADN was illustrated to demonstrate the validity of the methodology and its applicability to similar complex reaction processes.

  5. Information Retrieval System for Japanese Standard Disease-Code Master Using XML Web Service

    PubMed Central

    Hatano, Kenji; Ohe, Kazuhiko

    2003-01-01

    Information retrieval system of Japanese Standard Disease-Code Master Using XML Web Service is developed. XML Web Service is a new distributed processing system by standard internet technologies. With seamless remote method invocation of XML Web Service, users are able to get the latest disease code master information from their rich desktop applications or internet web sites, which refer to this service. PMID:14728364

  6. Dogmatism, Locus of Control, Perceived Counselor Self-Efficacy, and the Theoretical Orientation of Students in a Master's Level Counseling Practicum

    ERIC Educational Resources Information Center

    Benesh, Andrew Christopher

    2017-01-01

    Purpose: The purpose of this study was to fill a gap in the literature by examining the relationship between dogmatism, locus of control, counselor self-efficacy, and counselor theoretical orientation in a sample of master's level practicum students. Method: A total of 45 master's practicum students completed a series of four instruments, the DOG…

  7. Rapid prototyping of interfacing microcomponents for printed circuit board-level optical interconnects

    NASA Astrophysics Data System (ADS)

    Van Erps, Jürgen; Vervaeke, Michael; Thienpont, Hugo

    2012-01-01

    One of the important challenges for the deployment of the emerging breed of nanotechnology components is interfacing them with the external world, preferably accomplished with low-cost micro-optical devices. For the fabrication of this kind of micro-optical components, we make use of deep proton writing (DPW) as a generic rapid prototyping technology. DPW consists of bombarding polymer samples with swift protons, which results after chemical processing steps in high quality micro-optical components. The strength of the DPW micro-machining technology is the ability to fabricate monolithic building blocks that include micro-optical and mechanical functionalities which can be precisely integrated into more complex photonic systems. In this paper we give an overview of the process steps of the technology and we present several examples of micro-optical and micro-mechanical components, fabricated through DPW, targeting applications in printed circuit baordlevel optical interconnections. These include: high-precision 2-D fiber connectors, discrete out-of-plane coupling structures featuring high-quality 45° and curved micro-mirrors, arrays of high aspect ratio micro-pillars and backplane connectors. While DPW is clearly not a mass fabrication technique as such, one of its assets is that once the master component has been prototyped, a metal mould can be generated from the DPW master by applying electroplating. After removal of the plastic master, this metal mould can be used as a shim in a final microinjection moulding or hot embossing step. This way, the master component can be mass-produced at low cost in a wide variety of high-tech plastics.

  8. Cavity master equation for the continuous time dynamics of discrete-spin models.

    PubMed

    Aurell, E; Del Ferraro, G; Domínguez, E; Mulet, R

    2017-05-01

    We present an alternate method to close the master equation representing the continuous time dynamics of interacting Ising spins. The method makes use of the theory of random point processes to derive a master equation for local conditional probabilities. We analytically test our solution studying two known cases, the dynamics of the mean-field ferromagnet and the dynamics of the one-dimensional Ising system. We present numerical results comparing our predictions with Monte Carlo simulations in three different models on random graphs with finite connectivity: the Ising ferromagnet, the random field Ising model, and the Viana-Bray spin-glass model.

  9. Cavity master equation for the continuous time dynamics of discrete-spin models

    NASA Astrophysics Data System (ADS)

    Aurell, E.; Del Ferraro, G.; Domínguez, E.; Mulet, R.

    2017-05-01

    We present an alternate method to close the master equation representing the continuous time dynamics of interacting Ising spins. The method makes use of the theory of random point processes to derive a master equation for local conditional probabilities. We analytically test our solution studying two known cases, the dynamics of the mean-field ferromagnet and the dynamics of the one-dimensional Ising system. We present numerical results comparing our predictions with Monte Carlo simulations in three different models on random graphs with finite connectivity: the Ising ferromagnet, the random field Ising model, and the Viana-Bray spin-glass model.

  10. Modeling the Problem-Based Learning Preferences of McMaster University Undergraduate Medical Students Using a Discrete Choice Conjoint Experiment

    ERIC Educational Resources Information Center

    Cunningham, Charles E.; Deal, Ken; Neville, Alan; Rimas, Heather; Lohfeld, Lynne

    2006-01-01

    Objectives: To use methods from the field of marketing research to involve students in the redesign of McMaster University's small group, problem-based undergraduate medical education program. Methods: We used themes from a focus group conducted in an electronic decision support lab to compose 14 four-level educational attributes. Undergraduate…

  11. From master slave interferometry to complex master slave interferometry: theoretical work

    NASA Astrophysics Data System (ADS)

    Rivet, Sylvain; Bradu, Adrian; Maria, Michael; Feuchter, Thomas; Leick, Lasse; Podoleanu, Adrian

    2018-03-01

    A general theoretical framework is described to obtain the advantages and the drawbacks of two novel Fourier Domain Optical Coherence Tomography (OCT) methods denoted as Master/Slave Interferometry (MSI) and its extension denoted as Complex Master/Slave Interferometry (CMSI). Instead of linearizing the digital data representing the channeled spectrum before a Fourier transform can be applied to it (as in OCT standard methods), channeled spectrum is decomposed on the basis of local oscillations. This replaces the need for linearization, generally time consuming, before any calculation of the depth profile in the range of interest. In this model two functions, g and h, are introduced. The function g describes the modulation chirp of the channeled spectrum signal due to nonlinearities in the decoding process from wavenumber to time. The function h describes the dispersion in the interferometer. The utilization of these two functions brings two major improvements to previous implementations of the MSI method. The paper details the steps to obtain the functions g and h, and represents the CMSI in a matrix formulation that enables to implement easily this method in LabVIEW by using parallel programming with multi-cores.

  12. Velocity and structural model of the Lower Tagus Basin according to the study of environmental seismic noise

    NASA Astrophysics Data System (ADS)

    Gomes Torres, Ricardo Jorge; Furtado, José Augusto; Gonçalves Silva, Hugo; Borges, José Fernando; Caldeira, Bento; Bezzeghoud, Mourad; Carvalho, João

    2013-04-01

    Along his history the Lower Tagus Valley (LTV) region was shaken by several earthquakes, some of them produced in large ruptures of offshore structures located southwest of the Portuguese coastline. Among these is the Lisbon earthquake of 1 November 1755 (M~8.5-8.7), and other moderates earthquakes that were produced by local sources such as the 1344 (M6.0), 1531 (M7.1) and 1909 (M6.0) earthquakes. Previous simulations [1] have shown high velocity amplification in the region. The model used in the simulations was updated from low to high resolution using all the new available geophysical and geotechnical data on the area (seismic reflection, aeromagnetic, gravimetric, deep wells and geological outcrops) [2]. To confirm this model in the areas where it was derived by potential field methods we use broadband ambient noise measurements collected in about 200 points along seven profiles on the LTV basin, six perpendicular and one parallel to the basin axis. We applied the horizontal to vertical (H/V) spectral ratio method [3] to the seismic noise profiles in order to estimate the distribution of amplification in the basin. The H/V curves obtained reveals the existence of two low frequency peaks centered on 0.2 and 1 Hz [4]. These peaks are strongly related with the thickness of Cenozoic and alluvial sediments. The velocity model obtained by inversion of the H/V curves is in good agreement with borehole data, and results obtained using seismic reflection and gravimetric methods. However, aeromagnetic data overestimates the depth of the base of Cenozoic in the areas where it overlies directly the paleozoic basement, which we attribute either to the existence of Mesozoic units or higher magnetic susceptibilities than expected for the Paleozoic. References: [1] Bezzeghoud, M., Borges, J.F., M., Caldeira (2011). Ground motion simulations of the SW Iberia margin: rupture directivity and earth structure effects. Natural Hazards, pages 1-17. doi:10.1007/s11069-011-9925-2 [2] Torres, R.J.G., (2012). Modelo de velocidade da Bacia do Vale do Tejo: uma abordagem baseada no estudo do ruído sísmico ambiental, Master Thesis, Universidade de Évora, 83pp. [3] Nakamura, Y., 1989. A method for dynamic characteristics estimations of subsurface using microtremors on the ground surface, Quarterly Report, RTRI, Japan, v. 30, p. 25-33. [4] J.A. Furtado, Confirmação do modelo da estrutura 3D do Vale Inverior do Tejo a partir de dados de ruído sísmico ambiente, Master Thesis, Universidade de Évora, 136pp, 2010.

  13. Thermal aging of traditional and additively manufactured foams: analysis by time-temperature-superposition, constitutive, and finite-element models

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Maiti, A.; Weisgraber, T. H.; Small, W.

    Cellular solids or foams are a very important class of materials with diverse applications ranging from thermal insulation and shock absorbing support cushions, to light-weight structural and floatation components, and constitute crucial components in a large number of industries including automotive, aerospace, electronics, marine, biomedical, packaging, and defense. In many of these applications the foam material is subjected to long periods of continuous stress, which can, over time, lead to a permanent change in structure and a degradation in performance. In this report we summarize our modeling efforts to date on polysiloxane foam materials that form an important component inmore » our systems. Aging of the materials was characterized by two measured quantities, i.e., compression set and load retention. Results of accelerated aging experiments were analyzed by an automated time-temperaturesuperposition (TTS) approach, which creates a master curve that can be used for long-term predictions (over decades) under ambient conditions. When comparing such master curves for traditional (stochastic) foams with those for recently 3D-printed (i.e., additively manufactured, or AM) foams, it became clear that AM foams have superior aging behavior. To gain deeper understanding, we imaged the microstructure of both foams using X-ray computed tomography, and performed finite-element analysis of the mechanical response within these microstructures. This indicates a wider stress variation in the stochastic foam with points of more extreme local stress as compared to the 3D printed material.« less

  14. Master Curve and Conventional Fracture Toughness of Modified 9Cr-1Mo Steel

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Ji-Hyun, Yoon; Sung-Ho, Kim; Bong-Sang, Lee

    2006-07-01

    Modified 9Cr-1Mo steel is a primary candidate material for reactor pressure vessel of Very High Temperature Gas-Cooled Reactor (VHTR) in Korean Nuclear Hydrogen Development and Demonstration (NHDD) program. In this study, T0 reference temperature, J-R fracture resistance and Charpy impact properties were evaluated for commercial Grade 91 steel as preliminary tests for the selection of the RPV material for VHTR. The fracture toughness of the modified 9Cr-1Mo steel was compared with those of SA508-Gr.3. The objective of this study was to obtain pre-irradiation fracture toughness properties of modified 9Cr-1Mo steel as reference data for the radiation effects investigation. The resultsmore » are as follows. Charpy impact properties of the modified 9Cr-1Mo steel were similar to those of SA508-Gr.3. T0 reference temperatures were measured as -67.7 deg C and -72.4 deg C from the tests with standard PCVN (pre-cracked Charpy V-notch) and half sized PCVN specimens respectively, which were similar to results for SA508-Gr.3. The K{sub Jc} values of modified 9Cr-1Mo with test temperatures are successfully expressed with the Master Curve. The J-R fracture resistance of modified 9Cr-1Mo steel at room temperature was almost the same as that of SA508-Gr.3. On the other hand it was a little bit higher at an elevated temperature. (authors)« less

  15. Fracture toughness and the master curve for modified 9Cr-1Mo steel

    NASA Astrophysics Data System (ADS)

    Yoon, Ji-Hyun; Yoon, Eui-Pak

    2006-12-01

    Modified 9Cr-1Mo steel is a primary candidate material for the reactor pressure vessel of a Very High Temperature Gas-Cooled Reactor (VHTR) in the Korean Nuclear Hydrogen Development and Demonstration (NHDD) program. In this study, the T0 reference temperature, J-R fracture resistance and Charpy impact properties were evaluated for commercial Grade 91 steel as part of the preliminary testing for a selection of the RPV material for the VHTR. The fracture toughness of the modified 9Cr-1Mo steel was compared with that of SA508-Gr.3. The objective of this study was to obtain the pre-irradiation fracture toughness properties of the modified 9Cr-1Mo steel as reference data for an investigation of radiation effects. Charpy impact properties of the modified 9Cr-1Mo steel were similar to those of SA508-Gr.3. T0 reference temperatures were measured as -67.7 and -72.4°C from the tests with standard PCVN (pre-cracked Charpy V-notch) and half-sized PCVN specimens respectively, which were similar to the results for SA508-Gr.3. The KJc values of the modified 9Cr-1Mo steel with the test temperatures are successfully expressed by the Master Curve. The J-R fracture resistance of the modified 9Cr-1Mo steel at room temperature was nearly identical to that of SA508-Gr.3; in contrast, it was slightly higher at an elevated temperature.

  16. Learning curves for transapical transcatheter aortic valve replacement in the PARTNER-I trial: Technical performance, success, and safety.

    PubMed

    Suri, Rakesh M; Minha, Sa'ar; Alli, Oluseun; Waksman, Ron; Rihal, Charanjit S; Satler, Lowell P; Greason, Kevin L; Torguson, Rebecca; Pichard, Augusto D; Mack, Michael; Svensson, Lars G; Rajeswaran, Jeevanantham; Lowry, Ashley M; Ehrlinger, John; Mick, Stephanie L; Tuzcu, E Murat; Thourani, Vinod H; Makkar, Raj; Holmes, David; Leon, Martin B; Blackstone, Eugene H

    2016-09-01

    Introduction of hybrid techniques, such as transapical transcatheter aortic valve replacement (TA-TAVR), requires skills that a heart team must master to achieve technical efficiency: the technical performance learning curve. To date, the learning curve for TA-TAVR remains unknown. We therefore evaluated the rate at which technical performance improved, assessed change in occurrence of adverse events in relation to technical performance, and determined whether adverse events after TA-TAVR were linked to acquiring technical performance efficiency (the learning curve). From April 2007 to February 2012, 1100 patients, average age 85.0 ± 6.4 years, underwent TA-TAVR in the PARTNER-I trial. Learning curves were defined by institution-specific patient sequence number using nonlinear mixed modeling. Mean procedure time decreased from 131 to 116 minutes within 30 cases (P = .06) and device success increased to 90% by case 45 (P = .0007). Within 30 days, 354 patients experienced a major adverse event (stroke in 29, death in 96), with possibly decreased complications over time (P ∼ .08). Although longer procedure time was associated with more adverse events (P < .0001), these events were associated with change in patient risk profile, not the technical performance learning curve (P = .8). The learning curve for TA-TAVR was 30 to 45 procedures performed, and technical efficiency was achieved without compromising patient safety. Although fewer patients are now undergoing TAVR via nontransfemoral access, understanding TA-TAVR learning curves and their relationship with outcomes is important as the field moves toward next-generation devices, such as those to replace the mitral valve, delivered via the left ventricular apex. Copyright © 2016 The American Association for Thoracic Surgery. Published by Elsevier Inc. All rights reserved.

  17. Comparison of McMaster and FECPAKG2 methods for counting nematode eggs in the faeces of alpacas.

    PubMed

    Rashid, Mohammed H; Stevenson, Mark A; Waenga, Shea; Mirams, Greg; Campbell, Angus J D; Vaughan, Jane L; Jabbar, Abdul

    2018-05-02

    This study aimed to compare the FECPAK G2 and the McMaster techniques for counting of gastrointestinal nematode eggs in the faeces of alpacas using two floatation solutions (saturated sodium chloride and sucrose solutions). Faecal eggs counts from both techniques were compared using the Lin's concordance correlation coefficient and Bland and Altman statistics. Results showed moderate to good agreement between the two methods, with better agreement achieved when saturated sugar is used as a floatation fluid, particularly when faecal egg counts are less than 1000 eggs per gram of faeces. To the best of our knowledge this is the first study to assess agreement of measurements between McMaster and FECPAK G2 methods for estimating faecal eggs in South American camelids.

  18. [MODERN EDUCATIONAL TECHNOLOGY MASTERING PRACTICAL SKILLS OF GENERAL PRACTITIONERS].

    PubMed

    Kovalchuk, L I; Prokopchuk, Y V; Naydyonova, O V

    2015-01-01

    The article presents the experience of postgraduate training of general practitioners--family medicine. Identified current trends, forms and methods of pedagogical innovations that enhance the quality of learning and mastering the practical skills of primary professionals providing care.

  19. Computer programs for describing the recession of ground-water discharge and for estimating mean ground-water recharge and discharge from streamflow records-update

    USGS Publications Warehouse

    Rutledge, A.T.

    1998-01-01

    The computer programs included in this report can be used to develop a mathematical expression for recession of ground-water discharge and estimate mean ground-water recharge and discharge. The programs are intended for analysis of the daily streamflow record of a basin where one can reasonably assume that all, or nearly all, ground water discharges to the stream except for that which is lost to riparian evapotranspiration, and where regulation and diversion of flow can be considered to be negligible. The program RECESS determines the master reces-sion curve of streamflow recession during times when all flow can be considered to be ground-water discharge and when the profile of the ground-water-head distribution is nearly stable. The method uses a repetitive interactive procedure for selecting several periods of continuous recession, and it allows for nonlinearity in the relation between time and the logarithm of flow. The program RORA uses the recession-curve displacement method to estimate the recharge for each peak in the streamflow record. The method is based on the change in the total potential ground-water discharge that is caused by an event. Program RORA is applied to a long period of record to obtain an estimate of the mean rate of ground-water recharge. The program PART uses streamflow partitioning to estimate a daily record of base flow under the streamflow record. The method designates base flow to be equal to streamflow on days that fit a requirement of antecedent recession, linearly interpolates base flow for other days, and is applied to a long period of record to obtain an estimate of the mean rate of ground-water discharge. The results of programs RORA and PART correlate well with each other and compare reasonably with results of the corresponding manual method.

  20. A study on FlexMaster : a Ni-Ti rotary engine driven system for root canal preparation.

    PubMed

    Alam, M S; Bashar, A K; Begumr, J A; Kinoshita, J I

    2006-07-01

    In the present study, the effectiveness of recently introduced rotary Nickel Titanium FlexMaster engine driven system was evaluated for cleaning and shaping of root canals in extracted human teeth and compared with that done by the Nickel Titanium Flexofile hand instruments. A total of 40 root canals from 36 extracted mandibular and maxillary teeth with curvature ranging between 20 and 30 degree were divided into two groups, consisting 20 canals in each. FlexMaster instrumentation was done in 20 canals, using crown-down technique and manual filing with Flexofile was done in other 20 canals, using conventional and step-back techniques. 5.25% sodium hypochlorite (NaOCl) solution and 17% ethelene di-amine tetra-acetic acid (EDTA) were used alternatively for irrigation after canal preparation by each instrument size. Time needed for canal preparation of individual canal was recorded. A procedural error such as instrument breakage was also noted. After preparation, all the roots were cut longitudinally by using diamond burs in turbine handpiece and examined under scanning electron microscope. Apical region was quantified for debris and smear layer based on a 5-score numerical evaluation scale. The data established for scoring the debris and smear layer and preparation time of individual canal were analyzed statistically using the Mann-Whitney U test. Completely cleaned root canals were not found with any of the two instruments and none of the instruments maintained the original canal uniformity and regular dentine surface. Because significantly less debris was found in the apical region using the manual filing technique (p< 0.05). Thus the flexmaster system was found to produce less cleaner root canal walls than manual technique. Only one FlexMaster finishing file sized 30 was separated in the apical region during preparation of 30 degree curved canal. The time taken by FlexMaster was significantly better (p< 0.01) than that of hand instruments.

  1. The Relative Value of Skills, Knowledge, and Teaching Methods in Explaining Master of Business Administration (MBA) Program Return on Investment

    ERIC Educational Resources Information Center

    van Auken, Stuart; Wells, Ludmilla Gricenko; Chrysler, Earl

    2005-01-01

    In this article, the authors provide insight into alumni perceptions of Master of Business Administration (MBA) program return on investment (ROI). They sought to assess the relative value of skills, knowledge, and teaching methods in explaining ROI. By developing insight into the drivers of ROI, the real utility of MBA program ingredients can be…

  2. Competencies Needed by Korean HRD Master's Graduates: A Comparison between the ASTD WLP Competency Model and the Korean Study

    ERIC Educational Resources Information Center

    Lee, Yonghak

    2009-01-01

    The primary purpose of this study was to identify competencies needed by current human resource development (HRD) master's degree graduate students in Korea. The study used a quantitative method, the Delphi technique, in combination with a qualitative method consisting of a series of in-depth interviews. The Delphi technique was conducted using a…

  3. Arbitration in crossbar interconnect for low latency

    DOEpatents

    Ohmacht, Martin; Sugavanam, Krishnan

    2013-02-05

    A system and method and computer program product for reducing the latency of signals communicated through a crossbar switch, the method including using at slave arbitration logic devices associated with Slave devices for which access is requested from one or more Master devices, two or more priority vector signals cycled among their use every clock cycle for selecting one of the requesting Master devices and updates the respective priority vector signal used every clock cycle. Similarly, each Master for which access is requested from one or more Slave devices, can have two or more priority vectors and can cycle among their use every clock cycle to further reduce latency and increase throughput performance via the crossbar.

  4. CT protocol management: simplifying the process by using a master protocol concept

    PubMed Central

    Bour, Robert K.; Rubert, Nicholas; Wendt, Gary; Pozniak, Myron; Ranallo, Frank N.

    2015-01-01

    This article explains a method for creating CT protocols for a wide range of patient body sizes and clinical indications, using detailed tube current information from a small set of commonly used protocols. Analytical expressions were created relating CT technical acquisition parameters which can be used to create new CT protocols on a given scanner or customize protocols from one scanner to another. Plots of mA as a function of patient size for specific anatomical regions were generated and used to identify the tube output needs for patients as a function of size for a single master protocol. Tube output data were obtained from the DICOM header of clinical images from our PACS and patient size was measured from CT localizer radiographs under IRB approval. This master protocol was then used to create 11 additional master protocols. The 12 master protocols were further combined to create 39 single and multiphase clinical protocols. Radiologist acceptance rate of exams scanned using the clinical protocols was monitored for 12,857 patients to analyze the effectiveness of the presented protocol management methods using a two‐tailed Fisher's exact test. A single routine adult abdominal protocol was used as the master protocol to create 11 additional master abdominal protocols of varying dose and beam energy. Situations in which the maximum tube current would have been exceeded are presented, and the trade‐offs between increasing the effective tube output via 1) decreasing pitch, 2) increasing the scan time, or 3) increasing the kV are discussed. Out of 12 master protocols customized across three different scanners, only one had a statistically significant acceptance rate that differed from the scanner it was customized from. The difference, however, was only 1% and was judged to be negligible. All other master protocols differed in acceptance rate insignificantly between scanners. The methodology described in this paper allows a small set of master protocols to be adapted among different clinical indications on a single scanner and among different CT scanners. PACS number: 87.57.Q PMID:26219005

  5. Na-doped La0.7Ca0.3MnO3 compounds exhibiting a large magnetocaloric effect near room temperature

    NASA Astrophysics Data System (ADS)

    Chi Linh, Dinh; Thi Ha, Nguyen; Huu Duc, Nguyen; Giang Nam, Le Huu; Bau, Le Viet; Manh An, Nguyen; Yu, Seong-Cho; Dang Thanh, Tran

    2018-03-01

    In this work, we have investigated the magnetic properties and the magnetocaloric effect of La0.7-xNaxCa0.3MnO3 compounds, which were prepared by a conventional solid-state reaction technique. The Rietveld refinement results suggested that the samples are single phase belonging to an orthorhombic structure (space group Pnma). Analyzing temperature dependence of magnetization M(T) revealed that the Curie temperature (TC) increases with increasing Na content (x). Their TC value is found to be 260-298 K for x=0.0-0.1, respectively. Base on M(T) data measured at different applied magnetic fields (H), temperature dependence of magnetic entropy change ΔSm(T) data for all the samples was calculated by using a phenomenological model. In the vicinity of TC, -ΔSm(T) curve reaches a maximum value (denoted as |ΔSmax|), which gradually increases with increasing H. Under 12 kOe, the value of |ΔSmax| is in a range of 1.47-5.19 J/kg K corresponding to the relative cooling power RCP=57.12-75.88 J/kg. Applied the universal master curve method for the magnetic entropy change, we concluded that Na-doped in La0.7-xNaxCa0.3MnO3 compounds leads to modification the nature of the magnetic phase transition from the first- to the second-order.

  6. Protecting quantum Fisher information in curved space-time

    NASA Astrophysics Data System (ADS)

    Huang, Zhiming

    2018-03-01

    In this work, we investigate the quantum Fisher information (QFI) dynamics of a two-level atom interacting with quantized conformally coupled massless scalar fields in de Sitter-invariant vacuum. We first derive the master equation that governs its evolution. It is found that the QFI decays with evolution time. Furthermore, we propose two schemes to protect QFI by employing prior weak measurement (WM) and post measurement reversal (MR). We find that the first scheme can not always protect QFI and the second scheme has prominent advantage over the first scheme.

  7. Optically induced melting of colloidal crystals and their recrystallization.

    PubMed

    Harada, Masashi; Ishii, Masahiko; Nakamura, Hiroshi

    2007-04-15

    Colloidal crystals melt by applying focused light of optical tweezers and recrystallize after removing it. The disturbed zone by the light grows radially from the focus point and the ordering starts from the interface with the crystal. Although the larger disturbed zone is observed for the higher power optical tweezers, a master curve is extracted by normalization of the disturbed zone. The temporal changes of the normalized disturbed zone are well described with exponential functions, indicating that the melting and recrystallization process is governed by a simple relaxation mechanism.

  8. Elongational viscosity of photo-oxidated LDPE

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Rolón-Garrido, Víctor H., E-mail: victor.h.rolongarrido@tu-berlin.de, E-mail: manfred.wagner@tu-berlin.de; Wagner, Manfred H., E-mail: victor.h.rolongarrido@tu-berlin.de, E-mail: manfred.wagner@tu-berlin.de

    2014-05-15

    Sheets of low-density polyethylene (LDPE) were photo-oxidatively treated at room temperature, and subsequently characterized rheologically in the melt state by shear and uniaxial extensional experiments. For photo-oxidation, a xenon lamp was used to irradiate the samples for times between 1 day and 6 weeks. Linear-viscoelastic characterization was performed in a temperature range of 130 to 220°C to obtain the master curve at 170°C, the reference temperature at which the elongational viscosities were measured. Linear viscoelasticity is increasingly affected by increasing photo-oxidation due to crosslinking of LDPE, as corroborated by an increasing gel fraction as determined by a solvent extraction method.more » The elongational measurements reveal a strong enhancement of strain hardening until a saturation level is achieved. The elongational data are analyzed in the frame work of two constitutive equations, the rubber-like liquid and the molecular stress function models. Within the experimental window, timedeformation separability is confirmed for all samples, independent of the degree of photo-oxidation.« less

  9. Photo-oxidation of LDPE: Effects on elongational viscosity

    NASA Astrophysics Data System (ADS)

    Rolón-Garrido, Víctor H.; Wagner, Manfred H.

    2013-04-01

    Sheets of low-density polyethylene (LDPE) were photo-oxidatively treated at room temperature, and subsequently characterized rheologically in the melt state by shear and uniaxial extensional experiments. For photo-oxidation, a xenon lamp was used to irradiate the samples for times between 1 day and 6 weeks. Linear-viscoelastic characterization was performed in a temperature range of 130 to 220°C to obtain the master curve at 170°C, the reference temperature at which the elongational viscosities were measured. Linear viscoelasticity is increasingly affected by increasing photo-oxidation due to crosslinking of LDPE, as corroborated by an increasing gel fraction as determined by a solvent extraction method. The elongational measurements reveal a strong enhancement of strain hardening until a saturation level is achieved. The elongational data are analyzed in the frame work of two constitutive equations, the rubber-like liquid and the molecular stress function models. Within the experimental window, time-deformation separability is confirmed for all samples, independent of the degree of photo-oxidation.

  10. Elongational viscosity of photo-oxidated LDPE

    NASA Astrophysics Data System (ADS)

    Rolón-Garrido, Víctor H.; Wagner, Manfred H.

    2014-05-01

    Sheets of low-density polyethylene (LDPE) were photo-oxidatively treated at room temperature, and subsequently characterized rheologically in the melt state by shear and uniaxial extensional experiments. For photo-oxidation, a xenon lamp was used to irradiate the samples for times between 1 day and 6 weeks. Linear-viscoelastic characterization was performed in a temperature range of 130 to 220°C to obtain the master curve at 170°C, the reference temperature at which the elongational viscosities were measured. Linear viscoelasticity is increasingly affected by increasing photo-oxidation due to crosslinking of LDPE, as corroborated by an increasing gel fraction as determined by a solvent extraction method. The elongational measurements reveal a strong enhancement of strain hardening until a saturation level is achieved. The elongational data are analyzed in the frame work of two constitutive equations, the rubber-like liquid and the molecular stress function models. Within the experimental window, timedeformation separability is confirmed for all samples, independent of the degree of photo-oxidation.

  11. Distributed support vector machine in master-slave mode.

    PubMed

    Chen, Qingguo; Cao, Feilong

    2018-05-01

    It is well known that the support vector machine (SVM) is an effective learning algorithm. The alternating direction method of multipliers (ADMM) algorithm has emerged as a powerful technique for solving distributed optimisation models. This paper proposes a distributed SVM algorithm in a master-slave mode (MS-DSVM), which integrates a distributed SVM and ADMM acting in a master-slave configuration where the master node and slave nodes are connected, meaning the results can be broadcasted. The distributed SVM is regarded as a regularised optimisation problem and modelled as a series of convex optimisation sub-problems that are solved by ADMM. Additionally, the over-relaxation technique is utilised to accelerate the convergence rate of the proposed MS-DSVM. Our theoretical analysis demonstrates that the proposed MS-DSVM has linear convergence, meaning it possesses the fastest convergence rate among existing standard distributed ADMM algorithms. Numerical examples demonstrate that the convergence and accuracy of the proposed MS-DSVM are superior to those of existing methods under the ADMM framework. Copyright © 2018 Elsevier Ltd. All rights reserved.

  12. Rapid prototyping of microstructures in polydimethylsiloxane (PDMS) by direct UV-lithography.

    PubMed

    Scharnweber, Tim; Truckenmüller, Roman; Schneider, Andrea M; Welle, Alexander; Reinhardt, Martina; Giselbrecht, Stefan

    2011-04-07

    Microstructuring of polydimethylsiloxane (PDMS) is a key step for many lab-on-a-chip (LOC) applications. In general, the structure is generated by casting the liquid prepolymer against a master. The production of the master in turn calls for special equipment and know how. Furthermore, a given master only allows the reproduction of the defined structure. We report on a simple, cheap and practical method to produce microstructures in already cured PDMS by direct UV-lithography followed by chemical development. Due to the available options during the lithographic process like multiple exposures, the method offers a high design flexibility granting easy access to complex and stepped structures. Furthermore, no master is needed and the use of pre-cured PDMS allows processing at ambient (light) conditions. Features down to approximately 5 µm and a depth of 10 µm can be realised. As a proof of principle, we demonstrate the feasibility of the process by applying the structures to various established soft lithography techniques.

  13. Native Silk Feedstock as a Model Biopolymer: A Rheological Perspective.

    PubMed

    Laity, Peter R; Holland, Chris

    2016-08-08

    Variability in silk's rheology is often regarded as an impediment to understanding or successfully copying the natural spinning process. We have previously reported such variability in unspun native silk extracted straight from the gland of the domesticated silkworm Bombyx mori and discounted classical explanations such as differences in molecular weight and concentration. We now report that variability in oscillatory measurements can be reduced onto a simple master-curve through normalizing with respect to the crossover. This remarkable result suggests that differences between silk feedstocks are rheologically simple and not as complex as originally thought. By comparison, solutions of poly(ethylene-oxide) and hydroxypropyl-methyl-cellulose showed similar normalization behavior; however, the resulting curves were broader than for silk, suggesting greater polydispersity in the (semi)synthetic materials. Thus, we conclude Nature may in fact produce polymer feedstocks that are more consistent than typical man-made counterparts as a model for future rheological investigations.

  14. Science and Facebook: The same popularity law!

    PubMed

    Néda, Zoltán; Varga, Levente; Biró, Tamás S

    2017-01-01

    The distribution of scientific citations for publications selected with different rules (author, topic, institution, country, journal, etc…) collapse on a single curve if one plots the citations relative to their mean value. We find that the distribution of "shares" for the Facebook posts rescale in the same manner to the very same curve with scientific citations. This finding suggests that citations are subjected to the same growth mechanism with Facebook popularity measures, being influenced by a statistically similar social environment and selection mechanism. In a simple master-equation approach the exponential growth of the number of publications and a preferential selection mechanism leads to a Tsallis-Pareto distribution offering an excellent description for the observed statistics. Based on our model and on the data derived from PubMed we predict that according to the present trend the average citations per scientific publications exponentially relaxes to about 4.

  15. Science and Facebook: The same popularity law!

    PubMed Central

    Varga, Levente; Biró, Tamás S.

    2017-01-01

    The distribution of scientific citations for publications selected with different rules (author, topic, institution, country, journal, etc…) collapse on a single curve if one plots the citations relative to their mean value. We find that the distribution of “shares” for the Facebook posts rescale in the same manner to the very same curve with scientific citations. This finding suggests that citations are subjected to the same growth mechanism with Facebook popularity measures, being influenced by a statistically similar social environment and selection mechanism. In a simple master-equation approach the exponential growth of the number of publications and a preferential selection mechanism leads to a Tsallis-Pareto distribution offering an excellent description for the observed statistics. Based on our model and on the data derived from PubMed we predict that according to the present trend the average citations per scientific publications exponentially relaxes to about 4. PMID:28678796

  16. Time and frequency transfer by the Master-Slave Returnable Timing System technique - Application to solar power transmission

    NASA Technical Reports Server (NTRS)

    Lindsey, W. C.; Kantak, A. V.

    1979-01-01

    The concept of the Master Slave Returnable Timing System (MSRTS) is presented which combines the advantages of the master slave (MS) and the Returnable Timing System (RTS) for time and frequency transfer. The basic idea of MSRTS is to send the time-frequency signal received at a particular node back to the sending node. The delay accumulated by this return signal is used to advance the phase of the master (sending) node thereby canceling the effect of the delay introduced by the path. The method can be used in highly accurate clock distribution systems required in avionics, computer communications, and large retrodirective phased arrays such as the Solar Power Satellite.

  17. Hydrogen Field Test Standard: Laboratory and Field Performance

    PubMed Central

    Pope, Jodie G.; Wright, John D.

    2015-01-01

    The National Institute of Standards and Technology (NIST) developed a prototype field test standard (FTS) that incorporates three test methods that could be used by state weights and measures inspectors to periodically verify the accuracy of retail hydrogen dispensers, much as gasoline dispensers are tested today. The three field test methods are: 1) gravimetric, 2) Pressure, Volume, Temperature (PVT), and 3) master meter. The FTS was tested in NIST's Transient Flow Facility with helium gas and in the field at a hydrogen dispenser location. All three methods agree within 0.57 % and 1.53 % for all test drafts of helium gas in the laboratory setting and of hydrogen gas in the field, respectively. The time required to perform six test drafts is similar for all three methods, ranging from 6 h for the gravimetric and master meter methods to 8 h for the PVT method. The laboratory tests show that 1) it is critical to wait for thermal equilibrium to achieve density measurements in the FTS that meet the desired uncertainty requirements for the PVT and master meter methods; in general, we found a wait time of 20 minutes introduces errors < 0.1 % and < 0.04 % in the PVT and master meter methods, respectively and 2) buoyancy corrections are important for the lowest uncertainty gravimetric measurements. The field tests show that sensor drift can become a largest component of uncertainty that is not present in the laboratory setting. The scale was calibrated after it was set up at the field location. Checks of the calibration throughout testing showed drift of 0.031 %. Calibration of the master meter and the pressure sensors prior to travel to the field location and upon return showed significant drifts in their calibrations; 0.14 % and up to 1.7 %, respectively. This highlights the need for better sensor selection and/or more robust sensor testing prior to putting into field service. All three test methods are capable of being successfully performed in the field and give equivalent answers if proper sensors without drift are used. PMID:26722192

  18. Analysis of mathematical literacy ability based on goal orientation in model eliciting activities learning with murder strategy

    NASA Astrophysics Data System (ADS)

    Wijayanti, R.; Waluya, S. B.; Masrukan

    2018-03-01

    The purpose of this research are (1) to analyze the learning quality of MEAs with MURDER strategy, (2) to analyze students’ mathematical literacy ability based on goal orientation in MEAs learning with MURDER strategy. This research is a mixed method research of concurrent embedded type where qualitative method as the primary method. The data were obtained using the methods of scale, observation, test and interviews. The results showed that (1) MEAs Learning with MURDER strategy on students' mathematical literacy ability is qualified, (2) Students who have mastery goal characteristics are able to master the seven components of mathematical literacy process although there are still two components that the solution is less than the maximum. Students who have performance goal characteristics have not mastered the components of mathematical literacy process with the maximum, they are only able to master the ability of using mathematics tool and the other components of mathematical literacy process is quite good.

  19. The simulation method in learning interpersonal communication competence--experiences of masters' degree students of health sciences.

    PubMed

    Saaranen, Terhi; Vaajoki, Anne; Kellomäki, Marjaana; Hyvärinen, Marja-Leena

    2015-02-01

    This article describes the experiences of master students of nursing science in learning interpersonal communication competence through the simulation method. The exercises reflected challenging interactive situations in the field of health care. Few studies have been published on using the simulation method in the communication education of teachers, managers, and experts in this field. The aim of this study is to produce information which can be utilised in developing the simulation method to promote the interpersonal communication competence of master-level students of health sciences. This study used the qualitative, descriptive research method. At the Department of Nursing Science, the University of Eastern Finland, students major in nursing science specialise in nursing leadership and management, preventive nursing science, or nurse teacher education. Students from all three specialties taking the Challenging Situations in Speech Communication course participated (n=47). Essays on meaningful learning experiences collected using the critical incident technique, underwent content analysis. Planning of teaching, carrying out different stages of the simulation exercise, participant roles, and students' personal factors were central to learning interpersonal communication competence. Simulation is a valuable method in developing the interpersonal communication competence of students of health sciences at the masters' level. The methods used in the simulation teaching of emergency care are not necessarily applicable as such to communication education. The role of teacher is essential to supervising students' learning in simulation exercises. In the future, it is important to construct questions that help students to reflect specifically on communication. Copyright © 2014 Elsevier Ltd. All rights reserved.

  20. Force spectroscopy of quadruple H-bonded dimers by AFM: dynamic bond rupture and molecular time-temperature superposition.

    PubMed

    Zou, Shan; Schönherr, Holger; Vancso, G Julius

    2005-08-17

    We report on the application of the time-temperature superposition principle to supramolecular bond-rupture forces on the single-molecule level. The construction of force-loading rate master curves using atomic force microscopy (AFM)-based single-molecule force spectroscopy (SMFS) experiments carried out in situ at different temperatures allows one to extend the limited range of the experimentally accessible loading rates and hence to cross from thermodynamic nonequilibrium to quasi-equilibrium states. The approach is demonstrated for quadruple H-bonded ureido-4[1H]-pyrimidinone (UPy) moieties studied by variable-temperature SMFS in organic media. The unbinding forces of single quadruple H-bonding (UPy)2 complexes, which were identified based on a polymeric spacer strategy, were found to depend on the loading rate in the range of 5 nN/s to 500 nN/s at 301 K in hexadecane. By contrast, these rupture forces were independent of the loading rate from 5 to 200 nN/s at 330 K. These results indicate that the unbinding behavior of individual supramolecular complexes can be directly probed under both thermodynamic nonequilibrium and quasi-equilibrium conditions. On the basis of the time-temperature superposition principle, a master curve was constructed for a reference temperature of 301 K, and the crossover force (from loading-rate independent to -dependent regimes) was determined as approximately 145 pN (at a loading rate of approximately 5.6 nN/s). This approach significantly broadens the accessible loading-rate range and hence provides access to fine details of potential energy landscape of supramolecular complexes based on SMFS experiments.

  1. Molecular dynamics study of thermodynamic scaling of the glass-transition dynamics in ionic liquids over wide temperature and pressure ranges.

    PubMed

    Habasaki, J; Casalini, R; Ngai, K L

    2010-03-25

    Experimentally, superpositioning of dynamic properties such as viscosity, relaxation times, or diffusion coefficients under different conditions of temperature T, pressure P, and volume V by the scaling variable TV(gamma) (where gamma is a material constant) has been reported as a general feature of many kinds of glass-forming materials. In the present work, molecular dynamics (MD) simulations have been performed to study the scaling of dynamics near the glass-transition regime of ionic liquids. Scaling in the simulated 1-ethyl-3-methylimidazolium nitrate (EMIM-NO(3)) system has been tested over wide ranges of temperatures and pressures. TV(gamma) scaling of the dynamics is well described by master curves with gamma = 4.0 +/- 0.2 and 3.8 +/- 0.2 for cation and anion, respectively. Structures and Coulombic terms of the corresponding states are found to be quite similar. The temperature and pressure dependence of the pair correlation function show similar trends and therefore can be superpositioned onto the master curve. Although the behaviors with gamma = 4 might be expected from the relation, gamma = n/3, for the dynamics with the soft-core-type potential U = epsilon(sigma/r)(n), with n = 12, pair potentials used in the MD simulation have a more complex form, and not all the repulsive terms can play their roles in the heterogeneous structures determined by ion-ion interactions. Scaling is related to the common part of effective potentials related to the pair correlation functions, including the many-body effect in real space.

  2. Master Logic Diagram: method for hazard and initiating event identification in process plants.

    PubMed

    Papazoglou, I A; Aneziris, O N

    2003-02-28

    Master Logic Diagram (MLD), a method for identifying events initiating accidents in chemical installations, is presented. MLD is a logic diagram that resembles a fault tree but without the formal mathematical properties of the latter. MLD starts with a Top Event "Loss of Containment" and decomposes it into simpler contributing events. A generic MLD has been developed which may be applied to all chemical installations storing toxic and/or flammable substances. The method is exemplified through its application to an ammonia storage facility.

  3. Long Range Facilities Master Plan: 1986-2000, San Diego Unified School District.

    ERIC Educational Resources Information Center

    Blair, Billie; And Others

    The Long-Range Facilities Master Plan presents solution strategies and financing methods for accommodating a projected student enrollment increase of 45,000 between 1986 and 2000. This increase, plus limited financial resources, school use studies, and recent legislation, necessitated the plan. The issues include housing students, facility…

  4. The learning effect of intraoperative video-enhanced surgical procedure training.

    PubMed

    van Det, M J; Meijerink, W J H J; Hoff, C; Middel, L J; Koopal, S A; Pierie, J P E N

    2011-07-01

    The transition from basic skills training in a skills lab to procedure training in the operating theater using the traditional master-apprentice model (MAM) lacks uniformity and efficiency. When the supervising surgeon performs parts of a procedure, training opportunities are lost. To minimize this intervention by the supervisor and maximize the actual operating time for the trainee, we created a new training method called INtraoperative Video-Enhanced Surgical Training (INVEST). Ten surgical residents were trained in laparoscopic cholecystectomy either by the MAM or with INVEST. Each trainee performed six cholecystectomies that were objectively evaluated on an Objective Structured Assessment of Technical Skills (OSATS) global rating scale. Absolute and relative improvements during the training curriculum were compared between the groups. A questionnaire evaluated the trainee's opinion on this new training method. Skill improvement on the OSATS global rating scale was significantly greater for the trainees in the INVEST curriculum compared to the MAM, with mean absolute improvement 32.6 versus 14.0 points and mean relative improvement 59.1 versus 34.6% (P=0.02). INVEST significantly enhances technical and procedural skill development during the early learning curve for laparoscopic cholecystectomy. Trainees were positive about the content and the idea of the curriculum.

  5. Master-slave interferometry for parallel spectral domain interferometry sensing and versatile 3D optical coherence tomography.

    PubMed

    Podoleanu, Adrian Gh; Bradu, Adrian

    2013-08-12

    Conventional spectral domain interferometry (SDI) methods suffer from the need of data linearization. When applied to optical coherence tomography (OCT), conventional SDI methods are limited in their 3D capability, as they cannot deliver direct en-face cuts. Here we introduce a novel SDI method, which eliminates these disadvantages. We denote this method as Master - Slave Interferometry (MSI), because a signal is acquired by a slave interferometer for an optical path difference (OPD) value determined by a master interferometer. The MSI method radically changes the main building block of an SDI sensor and of a spectral domain OCT set-up. The serially provided signal in conventional technology is replaced by multiple signals, a signal for each OPD point in the object investigated. This opens novel avenues in parallel sensing and in parallelization of signal processing in 3D-OCT, with applications in high- resolution medical imaging and microscopy investigation of biosamples. Eliminating the need of linearization leads to lower cost OCT systems and opens potential avenues in increasing the speed of production of en-face OCT images in comparison with conventional SDI.

  6. Design framework of a teleoperating system for a magnetically levitated robot with force feedback

    NASA Astrophysics Data System (ADS)

    Tsuda, Naoaki; Kato, Norihiko; Nomura, Yoshihiko; Matsui, Hirokazu

    2002-02-01

    Precise works and manipulating micro objects are tough jobs for operators both mentally and physically. To execute these jobs smoothly without feeling wrongness, use of master-slave system is preferable because position and force are able to be scaled up and down as well under the system. In this study we develop a master-slave system where the size of a slave robot is very small and the slave robot is levitated by magnetic forces. In distinction from ordinary master- slave systems, the levitated robot does not get any other contact forces from outside. Thus we introduce a method using an impedance model for constructing the master-slave system. We confirmed the effectiveness of the positioning control algorithm through experiments.

  7. Damage Proxy Map from Interferometric Synthetic Aperture Radar Coherence

    NASA Technical Reports Server (NTRS)

    Webb, Frank H. (Inventor); Yun, Sang-Ho (Inventor); Fielding, Eric Jameson (Inventor); Simons, Mark (Inventor)

    2015-01-01

    A method, apparatus, and article of manufacture provide the ability to generate a damage proxy map. A master coherence map and a slave coherence map, for an area prior and subsequent to (including) a damage event are obtained. The slave coherence map is registered to the master coherence map. Pixel values of the slave coherence map are modified using histogram matching to provide a first histogram of the master coherence map that exactly matches a second histogram of the slave coherence map. A coherence difference between the slave coherence map and the master coherence map is computed to produce a damage proxy map. The damage proxy map is displayed with the coherence difference displayed in a visually distinguishable manner.

  8. Separation negatives from Kodak film types SO-368 and SO-242

    NASA Technical Reports Server (NTRS)

    Weinstein, M. S.

    1972-01-01

    Two master resolution friskets were produced on Kodak film types SO-368 and SO-242. These target masters consisted of 21 density steps with three-bar resolution targets at five modulation levels within each step. The target masters were contact printed onto Kodak separation negative film, type 4131, using both a contact printing frame and enlarger as one method of exposure, and a Miller-Holzwarth contact printer as the other exposing device. Red, green, and blue Wratten filters were used to filter the exposing source. Tray processing was done with DK-50 developer diluted 1:2 at a temperature of 70 F. The resolution values were read for the SO-368 and SO-242 target masters, and the red, green, and blue separation negatives.

  9. Study on real-time force feedback for a master-slave interventional surgical robotic system.

    PubMed

    Guo, Shuxiang; Wang, Yuan; Xiao, Nan; Li, Youxiang; Jiang, Yuhua

    2018-04-13

    In robot-assisted catheterization, haptic feedback is important, but is currently lacking. In addition, conventional interventional surgical robotic systems typically employ a master-slave architecture with an open-loop force feedback, which results in inaccurate control. We develop herein a novel real-time master-slave (RTMS) interventional surgical robotic system with a closed-loop force feedback that allows a surgeon to sense the true force during remote operation, provide adequate haptic feedback, and improve control accuracy in robot-assisted catheterization. As part of this system, we also design a unique master control handle that measures the true force felt by a surgeon, providing the basis for the closed-loop control of the entire system. We use theoretical and empirical methods to demonstrate that the proposed RTMS system provides a surgeon (using the master control handle) with a more accurate and realistic force sensation, which subsequently improves the precision of the master-slave manipulation. The experimental results show a substantial increase in the control accuracy of the force feedback and an increase in operational efficiency during surgery.

  10. An integrand reconstruction method for three-loop amplitudes

    NASA Astrophysics Data System (ADS)

    Badger, Simon; Frellesvig, Hjalte; Zhang, Yang

    2012-08-01

    We consider the maximal cut of a three-loop four point function with massless kinematics. By applying Gröbner bases and primary decomposition we develop a method which extracts all ten propagator master integral coefficients for an arbitrary triple-box configuration via generalized unitarity cuts. As an example we present analytic results for the three loop triple-box contribution to gluon-gluon scattering in Yang-Mills with adjoint fermions and scalars in terms of three master integrals.

  11. An Icelandic Version of McMasters Family Assessment Device (FAD)

    ERIC Educational Resources Information Center

    Juliusdottir, Gudlaug M.; Olafsdottir, Hrefna

    2015-01-01

    Purpose: An analysis of the psychometric properties of an Icelandic version of McMasters Family Assessment Device (FAD) was conducted in this study. Method: Two groups, clinical and nonclinical, comprising of 529 parents answered the FAD. The study examined the internal reliability and discriminant validity of the instrument in addition to…

  12. 2004 Strategic Master Plan for Higher Education. Update on Implementation

    ERIC Educational Resources Information Center

    Washington Higher Education Coordinating Board, 2005

    2005-01-01

    The 2004 Strategic Master Plan for Higher Education identified clear and measurable goals that focused on outcomes rather than inputs alone. To reinforce this outcomes-based approach, the plan proposed that the state develop a new funding method to reward public colleges and universities for student success. Specifically, it proposed that the…

  13. LGBTQ Studies and Interdisciplinarity: A Citation Analysis of Master's Theses

    ERIC Educational Resources Information Center

    Graziano, Vince

    2018-01-01

    Emergent programs or newly established areas of study are often viewed as interdisciplinary. But how is interdisciplinarity defined or measured? The identification of research methods and the selection of objects of inquiry are significant elements in this definition. Citation analysis, however, also plays a role. Citation patterns in master's…

  14. Perspectives on Peer-Mentoring from Taiwanese Science and Engineering Master's Students

    ERIC Educational Resources Information Center

    Lin, Yii-nii

    2014-01-01

    The purpose of this study is to describe the peer-mentoring experience from the perspective of 16 master's students majoring in science or engineering at a research-oriented university in Taiwan. Utilizing a qualitative method of phenomenology, these mentees shared their views about their peer-mentors through in-depth interviews. Participants…

  15. Online Master's Students' Perceptions of Institutional Supports and Resources: Initial Survey Results

    ERIC Educational Resources Information Center

    Milman, Natalie B.; Posey, Laurie; Pintz, Christine; Wright, Kayla; Zhou, Pearl

    2015-01-01

    This article presents the quantitative findings of an exploratory mixed methods study that investigated first- and second-year online graduate master's students': 1) perceptions of the importance of, and satisfaction with, administrative, academic, technical, and online community supports; 2) personal factors and grit level; and 3) differences, if…

  16. 40 CFR 89.307 - Dynamometer calibration.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... torque measurement for each range used by the following method: (1) Warm up the dynamometer following the... transfer standard may be used to verify the torque measurement system. (1) The master load-cell and read... master load-cell for each in-use range used. (5) The in-use torque measurement must be within 2 percent...

  17. 40 CFR 89.307 - Dynamometer calibration.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... torque measurement for each range used by the following method: (1) Warm up the dynamometer following the... transfer standard may be used to verify the torque measurement system. (1) The master load-cell and read... master load-cell for each in-use range used. (5) The in-use torque measurement must be within 2 percent...

  18. 40 CFR 89.307 - Dynamometer calibration.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... torque measurement for each range used by the following method: (1) Warm up the dynamometer following the... transfer standard may be used to verify the torque measurement system. (1) The master load-cell and read... master load-cell for each in-use range used. (5) The in-use torque measurement must be within 2 percent...

  19. Rapid and inexpensive fabrication of polymeric microfluidic devices via toner transfer masking

    PubMed Central

    Easley, Christopher J.; Benninger, Richard K. P.; Shaver, Jesse H.; Head, W. Steven; Piston, David W.

    2009-01-01

    Summary An alternative fabrication method is presented for production of masters for single- or multilayer polymeric microfluidic devices in a standard laboratory environment, precluding the need for a cleanroom. This toner transfer masking (TTM) method utilizes an office laser printer to generate a toner pattern which is thermally transferred to a metal master to serve as a mask for etching. With master fabrication times as little as one hour (depending on channel depth) using commercially-available equipment and supplies, this approach should make microfluidic technology more widely accessible to the non-expert—even the non-scientist. The cost of fabrication consumables was estimated to be < $1 per master, over an order of magnitude decrease in consumable costs compared to standard photolithography. In addition, the use of chemical etching allows accurate control over the height of raised features (i.e., channel depths), allowing the flexibility to fabricate multiple depths on a single master with little added time. Resultant devices are shown capable of pneumatic valving, three-dimensional channel formation (using layer-connecting vias), droplet fluidics, and cell imaging and staining. The multiple-depth capabilities of the method are proven useful for cellular analysis by fabrication of handheld, disposable devices used for trapping and imaging of live murine pancreatic islets. The precise fluidic control provided by the microfluidic platform allows subsequent fixing and staining of these cells without significant movement, thus spatial correlation of imaging and staining is attainable—even with rare alpha cells that constitute only ∼10% of the islet cells. PMID:19350094

  20. Mindfulness Based Stress Reduction for Academic Evaluation Anxiety: A Naturalistic Longitudinal Study.

    PubMed

    Dundas, Ingrid; Thorsheim, Torbjørn; Hjeltnes, Aslak; Binder, Per Einar

    2016-04-02

    Mindfulness based stress reduction (MBSR) for academic evaluation anxiety and self-confidence in 70 help-seeking bachelor's and master's students was examined. A repeated measures analysis of covariance on the 46 students who completed pretreatment and posttreatment measures (median age = 24 years, 83% women) showed that evaluation anxiety and self-confidence improved. A growth curve analysis with all 70 original participants showed reductions in both cognitive and emotional components of evaluation anxiety, and that reduction continued postintervention. Although more research is needed, this study indicates that MBSR may reduce evaluation anxiety.

  1. Target-based coherent beam combining of an optical phased array fed by a broadband laser source

    NASA Astrophysics Data System (ADS)

    Hyde, Milo W., IV; McCrae, Jack E.; Tyler, Glenn A.

    2017-11-01

    The target-based phasing of an optical phased array (OPA) fed by a broadband master oscillator laser source is investigated. The specific scenario examined here considers an OPA phasing through atmospheric turbulence on a rough curved object. An analytical expression for the detected or received intensity is derived. Gleaned from this expression are the conditions under which target-based phasing is possible. A detailed OPA wave optics simulation is performed to validate the theoretical findings. Key aspects of the simulation set-up as well as the results are thoroughly discussed.

  2. Yield stress and scaling of polyelectrolyte multilayer modified suspensions: effect of polyelectrolyte conformation during multilayer assembly.

    PubMed

    Hess, Andreas; Aksel, Nuri

    2013-09-10

    The yield stress of polyelectrolyte multilayer modified suspensions exhibits a surprising dependence on the polyelectrolyte conformation of multilayer films. The rheological data scale onto a universal master curve for each polyelectrolyte conformation as the particle volume fraction, φ, and the ionic strength of the background fluid, I, are varied. It is shown that rough films with highly coiled, brushy polyelectrolytes significantly enhance the yield stress. Moreover, via the ionic strength I of the background fluid, the dynamic yield stress of brushy polyelectrolyte multilayers can be finely adjusted over 2 decades.

  3. Data preparation techniques for a perinatal psychiatric study based on linked data.

    PubMed

    Xu, Fenglian; Hilder, Lisa; Austin, Marie-Paule; Sullivan, Elizabeth A

    2012-06-08

    In recent years there has been an increase in the use of population-based linked data. However, there is little literature that describes the method of linked data preparation. This paper describes the method for merging data, calculating the statistical variable (SV), recoding psychiatric diagnoses and summarizing hospital admissions for a perinatal psychiatric study. The data preparation techniques described in this paper are based on linked birth data from the New South Wales (NSW) Midwives Data Collection (MDC), the Register of Congenital Conditions (RCC), the Admitted Patient Data Collection (APDC) and the Pharmaceutical Drugs of Addiction System (PHDAS). The master dataset is the meaningfully linked data which include all or major study data collections. The master dataset can be used to improve the data quality, calculate the SV and can be tailored for different analyses. To identify hospital admissions in the periods before pregnancy, during pregnancy and after birth, a statistical variable of time interval (SVTI) needs to be calculated. The methods and SPSS syntax for building a master dataset, calculating the SVTI, recoding the principal diagnoses of mental illness and summarizing hospital admissions are described. Linked data preparation, including building the master dataset and calculating the SV, can improve data quality and enhance data function.

  4. The bias, accuracy and precision of faecal egg count reduction test results in cattle using McMaster, Cornell-Wisconsin and FLOTAC egg counting methods.

    PubMed

    Levecke, B; Rinaldi, L; Charlier, J; Maurelli, M P; Bosco, A; Vercruysse, J; Cringoli, G

    2012-08-13

    The faecal egg count reduction test (FECRT) is the recommended method to monitor anthelmintic drug efficacy in cattle. There is a large variation in faecal egg count (FEC) methods applied to determine FECRT. However, it remains unclear whether FEC methods with an equal analytic sensitivity, but with different methodologies, result in equal FECRT results. We therefore, compared the bias, accuracy and precision of FECRT results for Cornell-Wisconsin (analytic sensitivity = 1 egg per gram faeces (EPG)), FLOTAC (analytic sensitivity = 1 EPG) and McMaster method (analytic sensitivity = 10 EPG) across four levels of egg excretion (1-49 EPG; 50-149 EPG; 150-299 EPG; 300-600 EPG). Finally, we assessed the sensitivity of the FEC methods to detect a truly reduced efficacy. To this end, two different criteria were used to define reduced efficacy based on FECR, including those described in the WAAVP guidelines (FECRT <95% and lower limit of 95%CI <90%) (Coles et al., 1992) and those proposed by El-Abdellati et al. (2010) (upper limit of 95%CI <95%). There was no significant difference in bias and accuracy of FECRT results across the three methods. FLOTAC provided the most precise FECRT results. Cornell-Wisconsin and McMaster gave similar imprecise results. FECRT were significantly underestimated when baseline FEC were low and drugs were more efficacious. For all FEC methods, precision and accuracy of the FECRT improved as egg excretion increased, this effect was greatest for McMaster and least for Cornell-Wisconsin. The sensitivity of the three methods to detect a truly reduced efficacy was high (>90%). Yet, the sensitivity of McMaster and Cornell-Wisconsin may drop when drugs only show sub-optimal efficacy. Overall, the study indicates that the precision of FECRT is affected by the methodology of FEC, and that the level of egg excretion should be considered in the final interpretation of the FECRT. However, more comprehensive studies are required to provide more insights into the complex interplay of factors inherent to study design (sample size and FEC method) and host-parasite interactions (level of egg excretion and aggregation across the host population). Copyright © 2012 Elsevier B.V. All rights reserved.

  5. DuPont Qualicon BAX System polymerase chain reaction assay. Performance Tested Method 100201.

    PubMed

    Tice, George; Andaloro, Bridget; Fallon, Dawn; Wallace, F Morgan

    2009-01-01

    A recent outbreak of Salmonella in peanut butter has highlighted the need for validation of rapid detection methods. A multilaboratory study for detecting Salmonella in peanut butter was conducted as part of the AOAC Research Institute Emergency Response Validation program for methods that detect outbreak threats to food safety. Three sites tested spiked samples from the same master mix according to the U.S. Food and Drug Administration's Bacteriological Analytical Manual (FDA-BAM) method and the BAX System method. Salmonella Typhimurium (ATCC 14028) was grown in brain heart infusion for 24 h at 37 degrees C, then diluted to appropriate levels for sample inoculation. Master samples of peanut butter were spiked at high and low target levels, mixed, and allowed to equilibrate at room temperature for 2 weeks. Spike levels were low [1.08 most probable number (MPN)/25 g]; high (11.5 MPN/25 g) and unspiked to serve as negative controls. Each master sample was divided into 25 g portions and coded to blind the samples. Twenty portions of each spiked master sample and five portions of the unspiked sample were tested at each site. At each testing site, samples were blended in 25 g portions with 225 mL prewarmed lactose broth until thoroughly homogenized, then allowed to remain at room temperature for 55-65 min. Samples were adjusted to a pH of 6.8 +/- 0.2, if necessary, and incubated for 22-26 h at 35 degrees C. Across the three reporting laboratories, the BAX System detected Salmonella in 10/60 low-spike samples and 58/60 high-spike samples. The reference FDA-BAM method yielded positive results for 11/60 low-spike and 58/60 high-spike samples. Neither method demonstrated positive results for any of the 15 unspiked samples.

  6. Implementation of authentic assessment in the project based learning to improve student's concept mastering

    NASA Astrophysics Data System (ADS)

    Sambeka, Yana; Nahadi, Sriyati, Siti

    2017-05-01

    The study aimed to obtain the scientific information about increase of student's concept mastering in project based learning that used authentic assessment. The research was conducted in May 2016 at one of junior high school in Bandung in the academic year of 2015/2016. The research method was weak experiment with the one-group pretest-posttest design. The sample was taken by random cluster sampling technique and the sample was 24 students. Data collected through instruments, i.e. written test, observation sheet, and questionnaire sheet. Student's concept mastering test obtained N-Gain of 0.236 with the low category. Based on the result of paired sample t-test showed that implementation of authentic assessment in the project based learning increased student's concept mastering significantly, (sig<0.05).

  7. Control of repulsive force in a virtual environment using an electrorheological haptic master for a surgical robot application

    NASA Astrophysics Data System (ADS)

    Oh, Jong-Seok; Choi, Seung-Hyun; Choi, Seung-Bok

    2014-01-01

    This paper presents control performances of a new type of four-degrees-of-freedom (4-DOF) haptic master that can be used for robot-assisted minimally invasive surgery (RMIS). By adopting a controllable electrorheological (ER) fluid, the function of the proposed master is realized as a haptic feedback as well as remote manipulation. In order to verify the efficacy of the proposed master and method, an experiment is conducted with deformable objects featuring human organs. Since the use of real human organs is difficult for control due to high cost and moral hazard, an excellent alternative method, the virtual reality environment, is used for control in this work. In order to embody a human organ in the virtual space, the experiment adopts a volumetric deformable object represented by a shape-retaining chain linked (S-chain) model which has salient properties such as fast and realistic deformation of elastic objects. In haptic architecture for RMIS, the desired torque/force and desired position originating from the object of the virtual slave and operator of the haptic master are transferred to each other. In order to achieve the desired torque/force trajectories, a sliding mode controller (SMC) which is known to be robust to uncertainties is designed and empirically implemented. Tracking control performances for various torque/force trajectories from the virtual slave are evaluated and presented in the time domain.

  8. Characterizing the Learning Curve of the VBLaST-PT© (Virtual Basic Laparoscopic Skill Trainer)

    PubMed Central

    Zhang, Likun; Sankaranarayanan, Ganesh; Arikatla, Venkata Sreekanth; Ahn, Woojin; Grosdemouge, Cristol; Rideout, Jesse M.; Epstein, Scott K.; De, Suvranu; Schwaitzberg, Steven D.; Jones, Daniel B.; Cao, Caroline G.L.

    2013-01-01

    Background and study aim Mastering laparoscopic surgical skills requires considerable time and effort. The Virtual Basic Laparoscopic Skill Trainer (VBLaST-PT©) is being developed as a computerized version of the peg transfer task of the Fundamentals of Laparoscopic Surgery (FLS) system using virtual reality technology. We assessed the learning curve of trainees on the VBLaST-PT© using the cumulative summation (CUSUM) method and compared them with those on the FLS to establish convergent validity for the VBLaST-PT©. Methods Eighteen medical students from were assigned randomly to one of three groups: control, VBLaST-training and FLS-training. The VBLaST and the FLS groups performed a total of 150 trials of the peg-transfer task over a three week period, five days a week. Their CUSUM scores were computed based on pre-defined performance criteria (junior, intermediate and senior levels). Results Of the six subjects in the VBLaST-training group, five achieved at least the “junior” level, three achieved the “intermediate” level and one achieved the “senior” level of performance criterion by the end of the 150 trials. In comparison, for the FLS group, three students achieved the “senior” criterion and all six students achieved the “intermediate” and “junior” criteria by the 150th trials. Both the VBLaST-PT© and the FLS systems showed significant skill improvement and retention, albeit with system specificity as measured by transfer of learning in the retention test: The VBLaST-trained group performed better on the VBLaST-PT© than on FLS (p=0.003), while the FLS-trained group performed better on the FLS than on VBLaST-PT© (p=0.002). Conclusion We characterized the learning curve for a virtual peg transfer task on the VBLaST-PT© and compared it with the FLS using CUSUM analysis. Subjects in both training groups showed significant improvement in skill performance, but the transfer of training between systems was not significant. PMID:23572217

  9. Deterministic analysis of extrinsic and intrinsic noise in an epidemiological model.

    PubMed

    Bayati, Basil S

    2016-05-01

    We couple a stochastic collocation method with an analytical expansion of the canonical epidemiological master equation to analyze the effects of both extrinsic and intrinsic noise. It is shown that depending on the distribution of the extrinsic noise, the master equation yields quantitatively different results compared to using the expectation of the distribution for the stochastic parameter. This difference is incident to the nonlinear terms in the master equation, and we show that the deviation away from the expectation of the extrinsic noise scales nonlinearly with the variance of the distribution. The method presented here converges linearly with respect to the number of particles in the system and exponentially with respect to the order of the polynomials used in the stochastic collocation calculation. This makes the method presented here more accurate than standard Monte Carlo methods, which suffer from slow, nonmonotonic convergence. In epidemiological terms, the results show that extrinsic fluctuations should be taken into account since they effect the speed of disease breakouts and that the gamma distribution should be used to model the basic reproductive number.

  10. Hierarchical quantum master equation approach to electronic-vibrational coupling in nonequilibrium transport through nanosystems

    NASA Astrophysics Data System (ADS)

    Schinabeck, C.; Erpenbeck, A.; Härtle, R.; Thoss, M.

    2016-11-01

    Within the hierarchical quantum master equation (HQME) framework, an approach is presented, which allows a numerically exact description of nonequilibrium charge transport in nanosystems with strong electronic-vibrational coupling. The method is applied to a generic model of vibrationally coupled transport considering a broad spectrum of parameters ranging from the nonadiabatic to the adiabatic regime and including both resonant and off-resonant transport. We show that nonequilibrium effects are important in all these regimes. In particular, in the off-resonant transport regime, the inelastic cotunneling signal is analyzed for a vibrational mode in full nonequilibrium, revealing a complex interplay of different transport processes and deviations from the commonly used G0/2 rule of thumb. In addition, the HQME approach is used to benchmark approximate master equation and nonequilibrium Green's function methods.

  11. Transmission and Reproduction of Force Sensation by Bilateral Control

    NASA Astrophysics Data System (ADS)

    Katsura, Seiichiro; Ohnishi, Kouhei

    Minimally invasive surgery (MIS) which thinks a great deal of patient’s quality of life (QOL) has attracted attention during about ten years. In this paper, it aims at development of the technology for transmitting force sensation required in medical treatment especially through surgical instruments, such as forceps. In bilateral control, it is a problem how master and slave robots realize the law of action and reaction to the environment. Mechanism of contact with environment and bilateral controller based on stiffness are shown. Master arm in contact with human and slave arm in contact with environment are given compliance, and stable contact with environment can be realized. The proposed method is applied to 3-link master-slave manipulators. As a result, transmission and reproduction of force sensation can be realized. The experimental results show viability of the proposed method.

  12. Master's level education in biomedical optics: four-year experience at the University of Latvia

    NASA Astrophysics Data System (ADS)

    Spigulis, Janis

    2000-06-01

    Pilot program for Master's studies on Biomedical Optics has been developed and launched at University of Latvia in 1995. The Curriculum contains several basic subjects like Fundamentals of Biomedical Optics, Medical Lightguides, Anatomy and Physiology, Lasers and Non-coherent Light Sources, Optical Instrumentation for Healthcare, Optical Methods for Patient Treatment, Basic Physics, etc. Special English Terminology and Laboratory-Clinical Praxis are also involved, and the Master Theses is the final step for the degree award. Following one four-year teaching experience, some observations, conclusions and eventual future activities are discussed.

  13. Master equations and the theory of stochastic path integrals

    NASA Astrophysics Data System (ADS)

    Weber, Markus F.; Frey, Erwin

    2017-04-01

    This review provides a pedagogic and self-contained introduction to master equations and to their representation by path integrals. Since the 1930s, master equations have served as a fundamental tool to understand the role of fluctuations in complex biological, chemical, and physical systems. Despite their simple appearance, analyses of master equations most often rely on low-noise approximations such as the Kramers-Moyal or the system size expansion, or require ad-hoc closure schemes for the derivation of low-order moment equations. We focus on numerical and analytical methods going beyond the low-noise limit and provide a unified framework for the study of master equations. After deriving the forward and backward master equations from the Chapman-Kolmogorov equation, we show how the two master equations can be cast into either of four linear partial differential equations (PDEs). Three of these PDEs are discussed in detail. The first PDE governs the time evolution of a generalized probability generating function whose basis depends on the stochastic process under consideration. Spectral methods, WKB approximations, and a variational approach have been proposed for the analysis of the PDE. The second PDE is novel and is obeyed by a distribution that is marginalized over an initial state. It proves useful for the computation of mean extinction times. The third PDE describes the time evolution of a ‘generating functional’, which generalizes the so-called Poisson representation. Subsequently, the solutions of the PDEs are expressed in terms of two path integrals: a ‘forward’ and a ‘backward’ path integral. Combined with inverse transformations, one obtains two distinct path integral representations of the conditional probability distribution solving the master equations. We exemplify both path integrals in analysing elementary chemical reactions. Moreover, we show how a well-known path integral representation of averaged observables can be recovered from them. Upon expanding the forward and the backward path integrals around stationary paths, we then discuss and extend a recent method for the computation of rare event probabilities. Besides, we also derive path integral representations for processes with continuous state spaces whose forward and backward master equations admit Kramers-Moyal expansions. A truncation of the backward expansion at the level of a diffusion approximation recovers a classic path integral representation of the (backward) Fokker-Planck equation. One can rewrite this path integral in terms of an Onsager-Machlup function and, for purely diffusive Brownian motion, it simplifies to the path integral of Wiener. To make this review accessible to a broad community, we have used the language of probability theory rather than quantum (field) theory and do not assume any knowledge of the latter. The probabilistic structures underpinning various technical concepts, such as coherent states, the Doi-shift, and normal-ordered observables, are thereby made explicit.

  14. Master equations and the theory of stochastic path integrals.

    PubMed

    Weber, Markus F; Frey, Erwin

    2017-04-01

    This review provides a pedagogic and self-contained introduction to master equations and to their representation by path integrals. Since the 1930s, master equations have served as a fundamental tool to understand the role of fluctuations in complex biological, chemical, and physical systems. Despite their simple appearance, analyses of master equations most often rely on low-noise approximations such as the Kramers-Moyal or the system size expansion, or require ad-hoc closure schemes for the derivation of low-order moment equations. We focus on numerical and analytical methods going beyond the low-noise limit and provide a unified framework for the study of master equations. After deriving the forward and backward master equations from the Chapman-Kolmogorov equation, we show how the two master equations can be cast into either of four linear partial differential equations (PDEs). Three of these PDEs are discussed in detail. The first PDE governs the time evolution of a generalized probability generating function whose basis depends on the stochastic process under consideration. Spectral methods, WKB approximations, and a variational approach have been proposed for the analysis of the PDE. The second PDE is novel and is obeyed by a distribution that is marginalized over an initial state. It proves useful for the computation of mean extinction times. The third PDE describes the time evolution of a 'generating functional', which generalizes the so-called Poisson representation. Subsequently, the solutions of the PDEs are expressed in terms of two path integrals: a 'forward' and a 'backward' path integral. Combined with inverse transformations, one obtains two distinct path integral representations of the conditional probability distribution solving the master equations. We exemplify both path integrals in analysing elementary chemical reactions. Moreover, we show how a well-known path integral representation of averaged observables can be recovered from them. Upon expanding the forward and the backward path integrals around stationary paths, we then discuss and extend a recent method for the computation of rare event probabilities. Besides, we also derive path integral representations for processes with continuous state spaces whose forward and backward master equations admit Kramers-Moyal expansions. A truncation of the backward expansion at the level of a diffusion approximation recovers a classic path integral representation of the (backward) Fokker-Planck equation. One can rewrite this path integral in terms of an Onsager-Machlup function and, for purely diffusive Brownian motion, it simplifies to the path integral of Wiener. To make this review accessible to a broad community, we have used the language of probability theory rather than quantum (field) theory and do not assume any knowledge of the latter. The probabilistic structures underpinning various technical concepts, such as coherent states, the Doi-shift, and normal-ordered observables, are thereby made explicit.

  15. Finding the Balance: Jan Kagarice, a Case Study of a Master Trombone Teacher

    ERIC Educational Resources Information Center

    Marston, Karen Lynn

    2011-01-01

    The purpose of this study was to investigate and document the pedagogical techniques practiced by Jan Kagarice, Adjunct Professor of Trombone at the University of North Texas. Given that the study of master teachers has been identified as a valid method for defining effective teaching (Duke & Simmons, 2006), the intended outcome was to…

  16. Microfluidics in the Undergraduate Laboratory: Device Fabrication and an Experiment to Mimic Intravascular Gas Embolism

    ERIC Educational Resources Information Center

    Jablonski, Erin L.; Vogel, Brandon M.; Cavanagh, Daniel P.; Beers, Kathryn L.

    2010-01-01

    A method to fabricate microfluidic devices and an experimental protocol to model intravascular gas embolism for undergraduate laboratories are presented. The fabrication process details how to produce masters on glass slides; these masters serve as molds to pattern channels in an elastomeric polymer that can be adhered to a substrate, resulting in…

  17. Turkish Student Teachers' Ideas about Diagrams of a Flower and a Plant Cell

    ERIC Educational Resources Information Center

    Topsakal, Unsal Umdu; Oversby, John

    2012-01-01

    In the present study, the understandings of student teachers (training for the primary phase and Master's degree students from a primary science and technology education department) about flowers and plant cells using the method of drawing in combination with interviews are explored. The data were gathered from 116 student teachers and 10 Master's…

  18. Room Use for Group Instruction in Regularly Scheduled Classes.

    ERIC Educational Resources Information Center

    Phay, John E.; McCary, Arthur D.

    A method by which accurate accounting by computer might be made of apace and room use by regularly scheduled classes in institutions of higher learning is furnished. Based on well-defined terms, a master room schedule and a master course schedule are prepared on computer cards. This information is then compared with the reported individual room…

  19. Do Master's in Social Work Programs Teach Empirically Supported Interventions? A Survey of Deans and Directors

    ERIC Educational Resources Information Center

    Woody, Jane D.; D'Souza, Henry J.; Dartman, Rebecca

    2006-01-01

    Objective: A questionnaire to examine efforts toward the teaching of empirically supported interventions (ESI) was mailed to the 165 deans and directors of Council on Social Work Education-accredited Master's in social work (MSW) programs; 66 (40%) responded. Method: Questions included program characteristics and items assessing both faculty and…

  20. TPACK Development in a Three-Year Online Masters Program: How Do Teacher Perceptions Align with Classroom Practice?

    ERIC Educational Resources Information Center

    Staus, Nancy; Gillow-Wiles, Henry; Niess, Margaret

    2014-01-01

    A new primarily distance education Master's degree program was focused on the development of technological pedagogical content knowledge (TPACK) for integrating appropriate digital technologies in mathematics and science classes. In this mixed-method multiple case study, we documented in-service K-8 teachers' perceptions of their TPACK…

  1. Effect of gold nanoparticles on structure and dynamics of binary Lennard-Jones liquid: direct space analysis.

    PubMed

    Separdar, L; Davatolhagh, S

    2013-02-01

    We investigate the static structure and diffusive dynamics of binary Lennard-Jones mixture upon supercooling in the presence of gold nanoparticle within the framework of the mode-coupling theory of the dynamic glass transition in the direct space by means of constant-NVT molecular dynamics simulations. It is found that the presence of gold nanoparticle causes the energy per particle and the pressure of this system to decrease with respect to the bulk binary Lennard-Jones mixture. Furthermore, the presence of nanoparticle has a direct effect on the liquid structure and causes the peaks of the radial distribution functions to become shorter with respect to the bulk binary Lennard-Jones liquid. The dynamics of the liquid at a given density is found to be consistent with the mode-coupling theory (MCT) predictions in a certain range at low temperatures. In accordance with the idealized MCT, the diffusion constants D(T) show a power-law behavior at low temperatures for both types of binary Lennard-Jones (BLJ) particles as well as the gold atoms comprising the nanoparticle. The mode-coupling crossover temperature T(c) is the same for all particle types; however, T(c)=0.4 is reduced with respect to that of the bulk BLJ liquid, and the γ exponent is found to depend on the particle type. The existence of the nanoparticle causes the short-time β-relaxation regime to shorten and the range of validity of the MCT shrinks with respect to the bulk BLJ. It is also found that at intermediate and low temperatures the curves of the mean-squared displacements (MSDs) versus tD(T) fall onto a master curve. The MSDs follow the master curve in an identical time range with the long-time α-relaxation regime of the mode-coupling theory. By obtaining the viscosity, it is observed that the Stokes-Einstein relation remains valid at high and intermediate temperatures but breaks down as the temperatures approach T(c) as a result of the cooperative motion or activated processes.

  2. Photometric evolution of seven recent novae and the double-component characterizing the light curve of those emitting in gamma rays

    NASA Astrophysics Data System (ADS)

    Munari, U.; Hambsch, F.-J.; Frigo, A.

    2017-08-01

    The BVI light curves of seven recent novae (I.e. V1534 Sco, V1535 Sco, V2949 Oph, V3661 Oph, MASTER OT J010603.18-744715.8, TCP J1734475-240942 and ASASSN-16ma) have been extensively mapped with daily robotic observations from Atacama (Chile): five belong to the Galactic bulge, one to the Small Magellanic Cloud and another is a Galactic disc object. The two programme novae detected in γ-rays by Fermi-LAT (I.e. TCP J1734475-240942 and ASASSN-16ma) are bulge objects with unevolved companions. They distinguish themselves by showing a double-component optical light curve. The first component to develop is the fireball from freely expanding, ballistic-launched ejecta, with a time of passage through maximum that is strongly dependent on wavelength (˜1 d delay between the B and I bands). The second component, emerging simultaneously with the nova detection in γ-rays, evolves at a slower pace, its optical brightness being proportional to the γ-ray flux, and its passage through maximum not dependent on wavelength. The fact that γ-rays are detected at a flux level that differs by four times from novae at the distance of the bulge seems to suggest that γ-ray emission is not a widespread property of normal novae. We discuss the advantages offered by high-quality photometric observations collected with only one telescope (as opposed to data provided by a number of different instruments). We also observe the effects of the wavelength dependence of fireball expansion, the recombination in the flashed wind of a giant companion, the subtle presence of hiccups and plateaus, and the super-soft X-ray emission and its switch-off. Four programme novae (V2949 Oph, V3661 Oph, TCP J18102829-2729590 and ASASSN-16ma) have normal dwarf companions: V1534 Sco contains an M3 III giant, V1535 Sco a K-type giant and MASTER OT J010603.18-744715.8 a subgiant. We also comment briefly on the maximum absolute magnitude relation with decline time (MMRD).

  3. Improved instrumental magnitude prediction expected from version 2 of the NASA SKY2000 master star catalog

    NASA Technical Reports Server (NTRS)

    Sande, C. B.; Brasoveanu, D.; Miller, A. C.; Home, A. T.; Tracewell, D. A.; Warren, W. H., Jr.

    1998-01-01

    The SKY2000 Master Star Catalog (MC), Version 2 and its predecessors have been designed to provide the basic astronomical input data needed for satellite acquisition and attitude determination on NASA spacecraft. Stellar positions and proper motions are the primary MC data required for operations support followed closely by the stellar brightness observed in various standard astronomical passbands. The instrumental red-magnitude prediction subsystem (REDMAG) in the MMSCAT software package computes the expected instrumental color index (CI) [sensor color correction] from an observed astronomical stellar magnitude in the MC and the characteristics of the stellar spectrum, astronomical passband, and sensor sensitivity curve. The computation is more error prone the greater the mismatch of the sensor sensitivity curve characteristics and those of the observed astronomical passbands. This paper presents the preliminary performance analysis of a typical red-sensitive CCDST during acquisition of sensor data from the two Ball CT-601 ST's onboard the Rossi X-Ray Timing Explorer (RXTE). A comparison is made of relative star positions measured in the ST FOV coordinate system with the expected results computed from the recently released Tycho Catalogue. The comparison is repeated for a group of observed stars with nearby, bright neighbors in order to determine the tracker behavior in the presence of an interfering, near neighbor (NN). The results of this analysis will be used to help define a new photoelectric photometric instrumental sensor magnitude system (S) that is based on several thousand bright star magnitudes observed with the PXTE ST's. This new system will be implemented in Version 2 of the SKY2000 MC to provide improved predicted magnitudes in the mission run catalogs.

  4. Excess entropy scaling for the segmental and global dynamics of polyethylene melts.

    PubMed

    Voyiatzis, Evangelos; Müller-Plathe, Florian; Böhm, Michael C

    2014-11-28

    The range of validity of the Rosenfeld and Dzugutov excess entropy scaling laws is analyzed for unentangled linear polyethylene chains. We consider two segmental dynamical quantities, i.e. the bond and the torsional relaxation times, and two global ones, i.e. the chain diffusion coefficient and the viscosity. The excess entropy is approximated by either a series expansion of the entropy in terms of the pair correlation function or by an equation of state for polymers developed in the context of the self associating fluid theory. For the whole range of temperatures and chain lengths considered, the two estimates of the excess entropy are linearly correlated. The scaled bond and torsional relaxation times fall into a master curve irrespective of the chain length and the employed scaling scheme. Both quantities depend non-linearly on the excess entropy. For a fixed chain length, the reduced diffusion coefficient and viscosity scale linearly with the excess entropy. An empirical reduction to a chain length-independent master curve is accessible for both dynamic quantities. The Dzugutov scheme predicts an increased value of the scaled diffusion coefficient with increasing chain length which contrasts physical expectations. The origin of this trend can be traced back to the density dependence of the scaling factors. This finding has not been observed previously for Lennard-Jones chain systems (Macromolecules, 2013, 46, 8710-8723). Thus, it limits the applicability of the Dzugutov approach to polymers. In connection with diffusion coefficients and viscosities, the Rosenfeld scaling law appears to be of higher quality than the Dzugutov approach. An empirical excess entropy scaling is also proposed which leads to a chain length-independent correlation. It is expected to be valid for polymers in the Rouse regime.

  5. Performance Evaluation and Durability Studies of Adhesive Bonds

    NASA Astrophysics Data System (ADS)

    Ranade, Shantanu Rajendra

    In this thesis, four test approaches were developed to characterize the adhesion performance and durability of adhesive bonds for specific applications in areas spanning from structural adhesive joints to popular confectionaries such as chewing gum. In the first chapter, a double cantilever beam (DCB) specimen geometry is proposed for combinatorial fracture studies of structural adhesive bonds. This specimen geometry enabled the characterization of fracture energy vs. bondline thickness trends through fewer tests than those required during a conventional "one at a time" characterization approach, potentially offering a significant reduction in characterization times. The second chapter investigates the adhesive fracture resistance and crack path selection in adhesive joints containing patterns of discreet localized weak interfaces created using physical vapor deposition of copper. In a DCB specimen tested under mode-I conditions, fracture energy within the patterned regions scaled according to a simple rule of mixture, while reverse R-curve and R-curve type trends were observed in the regions surrounding weak interface patterns. Under mixed mode conditions such that bonding surface with patterns is subjected to axial tension, fracture energy did not show R-curve type trends while it was observed that a crack could be made to avoid exceptionally weak interfaces when loaded such that bonding surface with defects is subjected to axial compression. In the third chapter, an adaptation of the probe tack test is proposed to characterize the adhesion behavior of gum cuds. This test method allowed the introduction of substrates with well-defined surface energies and topologies to study their effects on gum cud adhesion. This approach and reported insights could potentially be useful in developing chewing gum formulations that facilitate easy removal of improperly discarded gum cuds from adhering surfaces. In the fourth chapter we highlight a procedure to obtain insights into the long-term performance of silicone sealants designed for load-bearing applications such as solar panel support sealants. Using small strain constitutive tests and time-temperature-superposition principle, thermal shift factors were obtained and successfully used to characterize the creep rupture master curves for specific joint configurations, leading to insights into delayed failures corresponding to three years through experiments carried out in one month.

  6. A control method for bilateral teleoperating systems

    NASA Astrophysics Data System (ADS)

    Strassberg, Yesayahu

    1992-01-01

    The thesis focuses on control of bilateral master-slave teleoperators. The bilateral control issue of teleoperators is studied and a new scheme that overcomes basic unsolved problems is proposed. A performance measure, based on the multiport modeling method, is introduced in order to evaluate and understand the limitations of earlier published bilateral control laws. Based on the study evaluating the different methods, the objective of the thesis is stated. The proposed control law is then introduced, its ideal performance is demonstrated, and conditions for stability and robustness are derived. It is shown that stability, desired performance, and robustness can be obtained under the assumption that the deviation of the model from the actual system satisfies certain norm inequalities and the measurement uncertainties are bounded. The proposed scheme is validated by numerical simulation. The simulated system is based on the configuration of the RAL (Robotics and Automation Laboratory) telerobot. From the simulation results it is shown that good tracking performance can be obtained. In order to verify the performance of the proposed scheme when applied to a real hardware system, an experimental setup of a three degree of freedom master-slave teleoperator (i.e. three degree of freedom master and three degree of freedom slave robot) was built. Three basic experiments were conducted to verify the performance of the proposed control scheme. The first experiment verified the master control law and its contribution to the robustness and performance of the entire system. The second experiment demonstrated the actual performance of the system while performing a free motion teleoperating task. From the experimental results, it is shown that the control law has good performance and is robust to uncertainties in the models of the master and slave.

  7. Understanding the importance of the temperature dependence of viscosity on the crystallization dynamics in the Ge2Sb2Te5 phase-change material

    NASA Astrophysics Data System (ADS)

    Aladool, A.; Aziz, M. M.; Wright, C. D.

    2017-06-01

    The crystallization dynamics in the phase-change material Ge2Sb2Te5 is modelled using the more detailed Master equation method over a wide range of heating rates commensurate with published ultrafast calorimetry experiments. Through the attachment and detachment of monomers, the Master rate equation naturally traces nucleation and growth of crystallites with temperature history to calculate the transient distribution of cluster sizes in the material. Both the attachment and detachment rates in this theory are strong functions of viscosity, and thus, the value of viscosity and its dependence on temperature significantly affect the crystallization process. In this paper, we use the physically realistic Mauro-Yue-Ellison-Gupta-Allan viscosity model in the Master equation approach to study the role of the viscosity model parameters on the crystallization dynamics in Ge2Sb2Te5 under ramped annealing conditions with heating rates up to 4 × 104 K/s. Furthermore, due to the relatively low computational cost of the Master equation method compared to atomistic level computations, an iterative numerical approach was developed to fit theoretical Kissinger plots simulated with the Master equation system to experimental Kissinger plots from ultrafast calorimetry measurements at increasing heating rates. This provided a more rigorous method (incorporating both nucleation and growth processes) to extract the viscosity model parameters from the analysis of experimental data. The simulations and analysis revealed the strong coupling between the glass transition temperature and fragility index in the viscosity and crystallization models and highlighted the role of the dependence of the glass transition temperature on the heating rate for the accurate estimation of the fragility index of phase-change materials from the analysis of experimental measurements.

  8. Brownian motion in non-equilibrium systems and the Ornstein-Uhlenbeck stochastic process.

    PubMed

    Donado, F; Moctezuma, R E; López-Flores, L; Medina-Noyola, M; Arauz-Lara, J L

    2017-10-03

    The Ornstein-Uhlenbeck stochastic process is an exact mathematical model providing accurate representations of many real dynamic processes in systems in a stationary state. When applied to the description of random motion of particles such as that of Brownian particles, it provides exact predictions coinciding with those of the Langevin equation but not restricted to systems in thermal equilibrium but only conditioned to be stationary. Here, we investigate experimentally single particle motion in a two-dimensional granular system in a stationary state, consisting of 1 mm stainless balls on a plane circular surface. The motion of the particles is produced by an alternating magnetic field applied perpendicular to the surface of the container. The mean square displacement of the particles is measured for a range of low concentrations and it is found that following an appropriate scaling of length and time, the short-time experimental curves conform a master curve covering the range of particle motion from ballistic to diffusive in accordance with the description of the Ornstein-Uhlenbeck model.

  9. Piezoresistive strain sensing of carbon black /silicone composites above percolation threshold

    NASA Astrophysics Data System (ADS)

    Shang, Shuying; Yue, Yujuan; Wang, Xiaoer

    2016-12-01

    A series of flexible composites with a carbon black (CB) filled silicone rubber matrix were made by an improved process in this work. A low percolation threshold with a mass ratio of 2.99% CB was achieved. The piezoresistive behavior of CB/silicone composites above the critical value, with the mass ratio of carbon black to the silicone rubber ranging from 0.01 to 0.2, was studied. The piezoresistive behavior was different from each other for the composites with different CB contents. But, the composites show an excellent repeatability of piezoresistivity under cyclic compression, no matter with low filler content or with high filler content. The most interesting phenomena were that the plots of gauge factor versus strain of the composites with different CB contents constructed a master curve and the curve could be well fitted by a function. It was showed that the gauge factor of the composites was strain-controlled showing a promising prospect of application.

  10. On the consideration of scaling properties of extreme rainfall in Madrid (Spain) for developing a generalized intensity-duration-frequency equation and assessing probable maximum precipitation estimates

    NASA Astrophysics Data System (ADS)

    Casas-Castillo, M. Carmen; Rodríguez-Solà, Raúl; Navarro, Xavier; Russo, Beniamino; Lastra, Antonio; González, Paula; Redaño, Angel

    2018-01-01

    The fractal behavior of extreme rainfall intensities registered between 1940 and 2012 by the Retiro Observatory of Madrid (Spain) has been examined, and a simple scaling regime ranging from 25 min to 3 days of duration has been identified. Thus, an intensity-duration-frequency (IDF) master equation of the location has been constructed in terms of the simple scaling formulation. The scaling behavior of probable maximum precipitation (PMP) for durations between 5 min and 24 h has also been verified. For the statistical estimation of the PMP, an envelope curve of the frequency factor ( k m ) based on a total of 10,194 station-years of annual maximum rainfall from 258 stations in Spain has been developed. This curve could be useful to estimate suitable values of PMP at any point of the Iberian Peninsula from basic statistical parameters (mean and standard deviation) of its rainfall series. [Figure not available: see fulltext.

  11. Multidomain proteins under force

    NASA Astrophysics Data System (ADS)

    Valle-Orero, Jessica; Andrés Rivas-Pardo, Jaime; Popa, Ionel

    2017-04-01

    Advancements in single-molecule force spectroscopy techniques such as atomic force microscopy and magnetic tweezers allow investigation of how domain folding under force can play a physiological role. Combining these techniques with protein engineering and HaloTag covalent attachment, we investigate similarities and differences between four model proteins: I10 and I91—two immunoglobulin-like domains from the muscle protein titin, and two α + β fold proteins—ubiquitin and protein L. These proteins show a different mechanical response and have unique extensions under force. Remarkably, when normalized to their contour length, the size of the unfolding and refolding steps as a function of force reduces to a single master curve. This curve can be described using standard models of polymer elasticity, explaining the entropic nature of the measured steps. We further validate our measurements with a simple energy landscape model, which combines protein folding with polymer physics and accounts for the complex nature of tandem domains under force. This model can become a useful tool to help in deciphering the complexity of multidomain proteins operating under force.

  12. A Simple "Boxed Molecular Kinetics" Approach To Accelerate Rare Events in the Stochastic Kinetic Master Equation.

    PubMed

    Shannon, Robin; Glowacki, David R

    2018-02-15

    The chemical master equation is a powerful theoretical tool for analyzing the kinetics of complex multiwell potential energy surfaces in a wide range of different domains of chemical kinetics spanning combustion, atmospheric chemistry, gas-surface chemistry, solution phase chemistry, and biochemistry. There are two well-established methodologies for solving the chemical master equation: a stochastic "kinetic Monte Carlo" approach and a matrix-based approach. In principle, the results yielded by both approaches are identical; the decision of which approach is better suited to a particular study depends on the details of the specific system under investigation. In this Article, we present a rigorous method for accelerating stochastic approaches by several orders of magnitude, along with a method for unbiasing the accelerated results to recover the "true" value. The approach we take in this paper is inspired by the so-called "boxed molecular dynamics" (BXD) method, which has previously only been applied to accelerate rare events in molecular dynamics simulations. Here we extend BXD to design a simple algorithmic strategy for accelerating rare events in stochastic kinetic simulations. Tests on a number of systems show that the results obtained using the BXD rare event strategy are in good agreement with unbiased results. To carry out these tests, we have implemented a kinetic Monte Carlo approach in MESMER, which is a cross-platform, open-source, and freely available master equation solver.

  13. Relation between muscle mass, motor units and type of training in master athletes.

    PubMed

    Drey, Michael; Sieber, Cornel C; Degens, Hans; McPhee, Jamie; Korhonen, Marko T; Müller, Klaus; Ganse, Bergita; Rittweger, Jörn

    2016-01-01

    The aim of this study was to measure the number of motor units and muscle mass in power-trained and endurance-trained master athletes compared with community-dwelling older adults. Seventy-five master athletes (52 power- and 23 endurance-trained athletes) were recruited at the 2012 European Veteran Athletics Championships in Zittau (Germany). One hundred and forty-nine community-dwelling older adults served as controls. In all participants, the motor unit number index (MUNIX) in the hypothenar muscle and whole body muscle mass was determined by bioelectrical impedance analysis (BIA). In both male and female master athletes, there were significant negative correlations between age and muscle mass (female: r = -0·510, P = 0·002; male: r = -0·714, P<0·001). Master athletes showed a weak correlation (r = -0·295, P = 0·010) between MUNIX and age. Master athletes exhibited significantly higher values than the control group with regard to both muscle mass (P = 0·002) and motor units (P = 0·004). Subanalysis showed that only power trained master athletes had both a larger muscle mass (P<0·001) and a higher MUNIX (P = 0·014) than the control group. Among the master athletes, power-trained athletes had a larger (P<0·001) muscle mass than endurance-trained athletes. The present data of master athletes are compatible with the hypothesis of an age-related decline in whole body muscle mass and motor units. Nevertheless, the data suggest that the master athletes' high level of physical activity may protect motoneurons. In addition, power training seems to have a positive effect on muscle mass and could therefore be an effective method of training to prevent sarcopenia. © 2014 Scandinavian Society of Clinical Physiology and Nuclear Medicine. Published by John Wiley & Sons Ltd.

  14. Splitting nodes and linking channels: A method for assembling biocircuits from stochastic elementary units

    NASA Astrophysics Data System (ADS)

    Ferwerda, Cameron; Lipan, Ovidiu

    2016-11-01

    Akin to electric circuits, we construct biocircuits that are manipulated by cutting and assembling channels through which stochastic information flows. This diagrammatic manipulation allows us to create a method which constructs networks by joining building blocks selected so that (a) they cover only basic processes; (b) it is scalable to large networks; (c) the mean and variance-covariance from the Pauli master equation form a closed system; and (d) given the initial probability distribution, no special boundary conditions are necessary to solve the master equation. The method aims to help with both designing new synthetic signaling pathways and quantifying naturally existing regulatory networks.

  15. "I Am Different from Other Women in the World": The Experiences of Saudi Arabian Women Studying Online in International Master Programmes

    ERIC Educational Resources Information Center

    Szilagyi, Annamaria

    2015-01-01

    This paper presents findings from a qualitative study that investigated seven female Saudi Arabian students of the University of Liverpool's online Masters programmes. Qualitative, first-person research methods and hermeneutic phenomenology were chosen for the analysis and interpretation of transcripts (Langeveld, 1983; van Manen, 1997; Creswell,…

  16. Methods, Theory, and the Practice of Feminist Research: A Response to Janet Chafetz

    ERIC Educational Resources Information Center

    Walker, Alexis J.

    2004-01-01

    Janet Chafetz dismisses Audre Lorde's dictum that you cannot dismantle the master's house using the master's tools. Instead, she argues compellingly that feminists draw from the same tool kit from which all social scientists draw and not from feminist theory and feminist methodology. It is perhaps an indication of how far we have come that four…

  17. Distributed Leadership an Instrument for School Improvement: The Study of Public Senior High Schools in Ghana

    ERIC Educational Resources Information Center

    Dampson, Dandy George; Havor, Felicia Mensah; Laryea, Prince

    2018-01-01

    The purpose of the study was to investigate the influence of distributed leadership in Public Senior High Schools (SHS) with regard to school improvement. Using the Explanatory Sequential Mixed-Method design, 92 teachers and 4 head masters and 4 assistant head masters were randomly and census sampled. Three research questions were formulated and…

  18. Simultaneous master-slave Omega pairs. [navigation system featuring low cost receiver

    NASA Technical Reports Server (NTRS)

    Burhans, R. W.

    1974-01-01

    Master-slave sequence ordering of the Omega system is suggested as a method of improving the pair geometry for low-cost receiver user benefit. The sequence change will not affect present sophisticated processor users other than require new labels for some pair combinations, but may require worldwide transmitter operators to slightly alter their long-range synchronizing techniques.

  19. Improving Ion Mobility Spectrometry Detection Methods for Trace Forensics and Military Field Applications

    DTIC Science & Technology

    2016-10-11

    UNIFORMED SERVICES UNIVERSITY OF THE HEALTH SCIENCES F. EDWARD HEBERT SCHOOL OF MEDICINE 4301 JONES BRIDGE ROAD BETHESDA, MARYLAND 20814-4799...ofPublic Health (Dr.P.H.) Master ofScience Degrees Departmental -Clinical Psychology -Environmental Health Sciences -Medical Psychology -Medical...Zoology -Pathology Interdisciplinary -Emerging Infectious Diseases -Molecular & Cell Biology -Neuroscience -Molecular & Cell Biology -Public Health Masters

  20. An Interpretive Master Plan at the Museum of Fine Arts, Houston

    ERIC Educational Resources Information Center

    Schneider, Beth B.

    2008-01-01

    This case study presents the methods the staff at the Museum of Fine Arts, Houston used to develop and implement an interpretive master plan from 1996-2000. The process can be a model for other museums. Looking back a decade after the plan was developed provides insights into the role of interpretive plans as statements of goals, expressions of…

  1. ABC Assay: Method Development and Application to Quantify the Role of Three DWV Master Variants in Overwinter Colony Losses of European Honey Bees.

    PubMed

    Kevill, Jessica L; Highfield, Andrea; Mordecai, Gideon J; Martin, Stephen J; Schroeder, Declan C

    2017-10-27

    Deformed wing virus (DWV) is one of the most prevalent honey bee viral pathogens in the world. Typical of many RNA viruses, DWV is a quasi-species, which is comprised of a large number of different variants, currently consisting of three master variants: Type A, B, and C. Little is known about the impact of each variant or combinations of variants upon the biology of individual hosts. Therefore, we have developed a new set of master variant-specific DWV primers and a set of standards that allow for the quantification of each of the master variants. Competitive reverse transcriptase polymerase chain reaction (RT-PCR) experimental design confirms that each new DWV primer set is specific to the retrospective master variant. The sensitivity of the ABC assay is dependent on whether DNA or RNA is used as the template and whether other master variants are present in the sample. Comparison of the overall proportions of each master variant within a sample of known diversity, as confirmed by next-generation sequence (NGS) data, validates the efficiency of the ABC assay. The ABC assay was used on archived material from a Devon overwintering colony loss (OCL) 2006-2007 study; further implicating DWV type A and, for the first time, possibly C in the untimely collapse of honey bee colonies. Moreover, in this study DWV type B was not associated with OCL. The use of the ABC assay will allow researchers to quickly and cost effectively pre-screen for the presence of DWV master variants in honey bees.

  2. Incorporating active-learning techniques into the photonics-related teaching in the Erasmus Mundus Master in "Color in Informatics and Media Technology"

    NASA Astrophysics Data System (ADS)

    Pozo, Antonio M.; Rubiño, Manuel; Hernández-Andrés, Javier; Nieves, Juan L.

    2014-07-01

    In this work, we present a teaching methodology using active-learning techniques in the course "Devices and Instrumentation" of the Erasmus Mundus Master's Degree in "Color in Informatics and Media Technology" (CIMET). A part of the course "Devices and Instrumentation" of this Master's is dedicated to the study of image sensors and methods to evaluate their image quality. The teaching methodology that we present consists of incorporating practical activities during the traditional lectures. One of the innovative aspects of this teaching methodology is that students apply the concepts and methods studied in class to real devices. For this, students use their own digital cameras, webcams, or cellphone cameras in class. These activities provide students a better understanding of the theoretical subject given in class and encourage the active participation of students.

  3. A Synthesis of Students' Theses in the Accredited HHSI Master's Programme.

    PubMed

    Kinnunen, Ulla-Mari; Saranto, Kaija

    2018-01-01

    Education in Health Informatics (HI) has been a key priority to guarantee knowledge and skills for professionals working in healthcare settings. One of the early academic models to teach HI are the recommendations provided by the International Medical Informatics Association. The paper describes the curriculum developed for master's degrees and the status of a paradigm used in informatics education, as well as research in the health and human services fields. The aim is to synthesise the methodological focuses in students' theses and discuss the future needs for development. The paradigm guides informatics research. The research focuses, questions and applied research methods were coded for 152 master's degree theses. Based on the results, the most often used method was qualitative. The most frequent research area was steering and organising of information management in work processes. The results guide teachers in supervising the theses of the Health and Human Services Informatics (HHSI) programme and tutoring new students.

  4. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Anastasiou, Charalampos; Duhr, Claude; Dulat, Falko

    We present methods to compute higher orders in the threshold expansion for the one-loop production of a Higgs boson in association with two partons at hadron colliders. This process contributes to the N 3LO Higgs production cross section beyond the soft-virtual approximation. We use reverse unitarity to expand the phase-space integrals in the small kinematic parameters and to reduce the coefficients of the expansion to a small set of master integrals. We describe two methods for the calculation of the master integrals. The first was introduced for the calculation of the soft triple-real radiation relevant to N 3LO Higgs production.more » The second uses a particular factorization of the three body phase-space measure and the knowledge of the scaling properties of the integral itself. Our result is presented as a Laurent expansion in the dimensional regulator, although some of the master integrals are computed to all orders in this parameter.« less

  5. The Effects of Salt on Rheological Properties of Asphalt after Long-Term Aging

    PubMed Central

    Yu, Xin; Luo, Yilin; Yin, Long

    2013-01-01

    Limited studies in recent years have shown that asphalt pavement subject to seawater in coastal regions or deicing salt in cold regions may be seriously damaged after being soaked in saline water for a long time. However, there is limited research into the influence of salt on rheological properties of asphalt after long-term aging. In this study, rheological properties of unmodified and polymer-modified asphalt after long-term aging were tested after being soaked in different concentrations of salt (0.3%~5%) for different durations (1 day~30 days). Orthogonal array based on the Taguchi method was used for experimental design. The frequency sweep tests were performed on the specimens of aged asphalt after being soaked for complex modulus and phase angle master curves and ultimate fatigue temperature. BBR tests were performed for stiffness. The test results indicate that saline water appears to reduce low temperature properties and fatigue resistance properties and improved high temperature properties of aged asphalt, and it also affects the sensitivity of complex modulus and phase angles at low frequencies. PMID:24459450

  6. Extracting the pair distribution function of liquids and liquid-vapor surfaces by grazing incidence x-ray diffraction mode.

    PubMed

    Vaknin, David; Bu, Wei; Travesset, Alex

    2008-07-28

    We show that the structure factor S(q) of water can be obtained from x-ray synchrotron experiments at grazing angle of incidence (in reflection mode) by using a liquid surface diffractometer. The corrections used to obtain S(q) self-consistently are described. Applying these corrections to scans at different incident beam angles (above the critical angle) collapses the measured intensities into a single master curve, without fitting parameters, which within a scale factor yields S(q). Performing the measurements below the critical angle for total reflectivity yields the structure factor of the top most layers of the water/vapor interface. Our results indicate water restructuring at the vapor/water interface. We also introduce a new approach to extract g(r), the pair distribution function (PDF), by expressing the PDF as a linear sum of error functions whose parameters are refined by applying a nonlinear least square fit method. This approach enables a straightforward determination of the inherent uncertainties in the PDF. Implications of our results to previously measured and theoretical predictions of the PDF are also discussed.

  7. The effects of salt on rheological properties of asphalt after long-term aging.

    PubMed

    Yu, Xin; Wang, Ying; Luo, Yilin; Yin, Long

    2013-01-01

    Limited studies in recent years have shown that asphalt pavement subject to seawater in coastal regions or deicing salt in cold regions may be seriously damaged after being soaked in saline water for a long time. However, there is limited research into the influence of salt on rheological properties of asphalt after long-term aging. In this study, rheological properties of unmodified and polymer-modified asphalt after long-term aging were tested after being soaked in different concentrations of salt (0.3%~5%) for different durations (1 day~30 days). Orthogonal array based on the Taguchi method was used for experimental design. The frequency sweep tests were performed on the specimens of aged asphalt after being soaked for complex modulus and phase angle master curves and ultimate fatigue temperature. BBR tests were performed for stiffness. The test results indicate that saline water appears to reduce low temperature properties and fatigue resistance properties and improved high temperature properties of aged asphalt, and it also affects the sensitivity of complex modulus and phase angles at low frequencies.

  8. A Comparison of Tension and Compression Creep in a Polymeric Composite and the Effects of Physical Aging on Creep Behavior

    NASA Technical Reports Server (NTRS)

    Gates, Thomas S.; Veazie, David R.; Brinson, L. Catherine

    1996-01-01

    Experimental and analytical methods were used to investigate the similarities and differences of the effects of physical aging on creep compliance of IM7/K3B composite loaded in tension and compression. Two matrix dominated loading modes, shear and transverse, were investigated for two load cases, tension and compression. The tests, run over a range of sub-glass transition temperatures, provided material constants, material master curves and aging related parameters. Comparing results from the short-term data indicated that although trends in the data with respect to aging time and aging temperature are similar, differences exist due to load direction and mode. The analytical model used for predicting long-term behavior using short-term data as input worked equally as well for the tension or compression loaded cases. Comparison of the loading modes indicated that the predictive model provided more accurate long term predictions for the shear mode as compared to the transverse mode. Parametric studies showed the usefulness of the predictive model as a tool for investigating long-term performance and compliance acceleration due to temperature.

  9. Report of the River Master of the Delaware River for the period December 1, 1984 - November 30, 1985

    USGS Publications Warehouse

    Schaefer, F.T.; Harkness, W.E.; Cecil, L.D.

    1986-01-01

    A Decree of the Supreme Court of the United States in 1954 established the position of Delaware River Master. The Decree authorizes diversions of water from the Delaware River basin and requires compensating releases from certain reservoirs of the City of New York to be made under the supervision and direction of the River Master. Reports to the Court, not less frequently than annually, were stipulated. During the 1985 report year, December 1, 1984, to November 30, 1985, precipitation and runoff varied from below average to above average in the Delaware River basin. For the year as a whole, precipitation was near average. Runoff was below average. Operations were under a status of drought warning or drought from January 23, 1984, through the end of the report year. Below-normal precipitation the first half of the year resulted in decreased storage in the reservoirs to record low levels by March 1, 1985. Storage remained at record low levels from March through September. Above-normal precipitation in September and November served to break the drought and increase storage into the normal zone of the operating curves for the reservoirs. Diversions from the Delaware River basin by New York City did not exceed those authorized by the terms of the Amended Decree or those invoked by the several emergency conservation measures throughout the year. There were no diversions from the Delaware River basin by New Jersey during the year. Releases were made as directed by the River Master at rates designed to meet the Montague flow objective on 82 days between June 14 and September 28. Releases were made at conservation rates or at rates designed to relieve thermal stress in the streams downstream from the reservoirs at other times. (See also W89-04133) (USGS)

  10. The Chandra Source Catalog: User Interface

    NASA Astrophysics Data System (ADS)

    Bonaventura, Nina; Evans, I. N.; Harbo, P. N.; Rots, A. H.; Tibbetts, M. S.; Van Stone, D. W.; Zografou, P.; Anderson, C. S.; Chen, J. C.; Davis, J. E.; Doe, S. M.; Evans, J. D.; Fabbiano, G.; Galle, E.; Gibbs, D. G.; Glotfelty, K. J.; Grier, J. D.; Hain, R.; Hall, D. M.; He, X.; Houck, J. C.; Karovska, M.; Lauer, J.; McCollough, M. L.; McDowell, J. C.; Miller, J. B.; Mitschang, A. W.; Morgan, D. L.; Nichols, J. S.; Nowak, M. A.; Plummer, D. A.; Primini, F. A.; Refsdal, B. L.; Siemiginowska, A. L.; Sundheim, B. A.; Winkelman, S. L.

    2009-01-01

    The Chandra Source Catalog (CSC) is the definitive catalog of all X-ray sources detected by Chandra. The CSC is presented to the user in two tables: the Master Chandra Source Table and the Table of Individual Source Observations. Each distinct X-ray source identified in the CSC is represented by a single master source entry and one or more individual source entries. If a source is unaffected by confusion and pile-up in multiple observations, the individual source observations are merged to produce a master source. In each table, a row represents a source, and each column a quantity that is officially part of the catalog. The CSC contains positions and multi-band fluxes for the sources, as well as derived spatial, spectral, and temporal source properties. The CSC also includes associated source region and full-field data products for each source, including images, photon event lists, light curves, and spectra. The master source properties represent the best estimates of the properties of a source, and are presented in the following categories: Position and Position Errors, Source Flags, Source Extent and Errors, Source Fluxes, Source Significance, Spectral Properties, and Source Variability. The CSC Data Access GUI provides direct access to the source properties and data products contained in the catalog. The user may query the catalog database via a web-style search or an SQL command-line query. Each query returns a table of source properties, along with the option to browse and download associated data products. The GUI is designed to run in a web browser with Java version 1.5 or higher, and may be accessed via a link on the CSC website homepage (http://cxc.harvard.edu/csc/). As an alternative to the GUI, the contents of the CSC may be accessed directly through a URL, using the command-line tool, cURL. Support: NASA contract NAS8-03060 (CXC).

  11. Shock melting method to determine melting curve by molecular dynamics: Cu, Pd, and Al.

    PubMed

    Liu, Zhong-Li; Zhang, Xiu-Lu; Cai, Ling-Cang

    2015-09-21

    A melting simulation method, the shock melting (SM) method, is proposed and proved to be able to determine the melting curves of materials accurately and efficiently. The SM method, which is based on the multi-scale shock technique, determines melting curves by preheating and/or prepressurizing materials before shock. This strategy was extensively verified using both classical and ab initio molecular dynamics (MD). First, the SM method yielded the same satisfactory melting curve of Cu with only 360 atoms using classical MD, compared to the results from the Z-method and the two-phase coexistence method. Then, it also produced a satisfactory melting curve of Pd with only 756 atoms. Finally, the SM method combined with ab initio MD cheaply achieved a good melting curve of Al with only 180 atoms, which agrees well with the experimental data and the calculated results from other methods. It turned out that the SM method is an alternative efficient method for calculating the melting curves of materials.

  12. Intuitive operability evaluation of surgical robot using brain activity measurement to determine immersive reality.

    PubMed

    Miura, Satoshi; Kobayashi, Yo; Kawamura, Kazuya; Seki, Masatoshi; Nakashima, Yasutaka; Noguchi, Takehiko; Kasuya, Masahiro; Yokoo, Yuki; Fujie, Masakatsu G

    2012-01-01

    Surgical robots have improved considerably in recent years, but intuitive operability, which represents user inter-operability, has not been quantitatively evaluated. Therefore, for design of a robot with intuitive operability, we propose a method to measure brain activity to determine intuitive operability. The objective of this paper is to determine the master configuration against the monitor that allows users to perceive the manipulator as part of their own body. We assume that the master configuration produces an immersive reality experience for the user of putting his own arm into the monitor. In our experiments, as subjects controlled the hand controller to position the tip of the virtual slave manipulator on a target in a surgical simulator, we measured brain activity through brain-imaging devices. We performed our experiments for a variety of master manipulator configurations with the monitor position fixed. For all test subjects, we found that brain activity was stimulated significantly when the master manipulator was located behind the monitor. We conclude that this master configuration produces immersive reality through the body image, which is related to visual and somatic sense feedback.

  13. Accuracy of five implant impression technique: effect of splinting materials and methods

    PubMed Central

    Cho, Sung-Bum

    2011-01-01

    PURPOSE The aim of this study was to evaluate the effect of dimensional stability of splinting material on the accuracy of master casts. MATERIALS AND METHODS A stainless steel metal model with 6 implants embedded was used as a master model. Implant level impressions were made after square impression copings were splinted using 5 different techniques as follows. (1) Splinted with autopolymerizing resin and sectioned, reconnected to compensate polymerization shrinkage before the impression procedure. (2) Splinted with autopolymerizing resin just before impression procedure. (3) Primary impression made with impression plaster and secondary impression were made over with polyether impression material. (4) Splinted with impression plaster. (5) Splinted with VPS bite registration material. From master model, 5 impressions and 5 experimental casts, total 25 casts were made for each of 5 splinting methods. The distortion values of each splinting methods were measured using coordinate measuring machine, capable of recordings in the x-, y-, z-axes. A one-way analysis of variance (ANOVA) at a confidence level of 95% was used to evaluate the data and Tukey's studentized range test was used to determine significant differences between the groups. RESULTS Group 1 showed best accuracy followed by Group 3 & 4. Group 2 and 5 showed relatively larger distortion value than other groups. No significant difference was found between group 3, 4, 5 in x-axis, group 2, 3, 4 in y-axis and group 1, 3, 4, 5 in z-axis (P<.0001). CONCLUSION Both Splinting impression copings with autopolymerizing resin following compensation of polymerization shrinkage and splinting method with impression plaster can enhance the accuracy of master cast and impression plaster can be used simple and effective splinting material for implant impression procedure. PMID:22259700

  14. Experience with SI units in biochemistry.

    PubMed

    Karnauchow, P N; Suvanto, L

    1976-03-20

    Use of Système International d'Unités (SI) for laboratory measurements was instituted Jan. 1, 1975 at two community hospitals. Beforehand, talks were given, pamphlets, conversion tables, new calibration curves and new master record cards were printed, computer cards were reprogrammed and conversion kits were prepared; the total cost was less than $200. After 6 months 16% of the medical staff had stopped converting SI units into conventional units, 78% were still occasionally converting units and 6% were routinely converting units. Changeover had been difficult for 25%, only a nuisance for 49% and easy for 26%. The patients' lives were not endangered by conversion.

  15. Tensile properties of HK31XA-H24 magnesium-alloy sheet under rapid-heating conditions and constant elevated temperatures

    NASA Technical Reports Server (NTRS)

    Gibbs, Thomas W

    1956-01-01

    Specimens of HK31XA-H24 magnesium-alloy sheet from an experimental batch were heated to failure at nominal temperature rates from 0.2 F to 100 F per second under constant-load conditions. Rapid-heating yield and rupture stresses are presented and compared with the yield and ultimate stresses from elevated-temperature tensile stress-strain tests for 1/2-hour exposure. Linear temperature-rate parameters were used to correlate rapid-heating results by constructing master curves which can be used for predicting yield stresses and temperatures and for estimating rupture stresses and temperatures.

  16. Flexural creep behaviour of jute polypropylene composites

    NASA Astrophysics Data System (ADS)

    Chandekar, Harichandra; Chaudhari, Vikas

    2016-09-01

    Present study is about the flexural creep behaviour of jute fabric reinforced polypropylene (Jute-PP) composites. The PP sheet and alkali treated jute fabric is stacked alternately and hot pressed in compression molding machine to get Jute-PP composite laminate. The flexural creep study is carried out on dynamic mechanical analyzer. The creep behaviour of the composite is modeled using four-parameter Burgers model. Short-term accelerated creep testing is conducted which is later used to predict long term creep behaviour. The feasibility of the construction of a master curve using the time-temperature superposition (TTS) principle to predict long term creep behavior of unreinforced PP and Jute-PP composite is investigated.

  17. Development of a StandAlone Surgical Haptic Arm.

    PubMed

    Jones, Daniel; Lewis, Andrew; Fischer, Gregory S

    2011-01-01

    When performing telesurgery with current commercially available Minimally Invasive Robotic Surgery (MIRS) systems, a surgeon cannot feel the tool interactions that are inherent in traditional laparoscopy. It is proposed that haptic feedback in the control of MIRS systems could improve the speed, safety and learning curve of robotic surgery. To test this hypothesis, a standalone surgical haptic arm (SASHA) capable of manipulating da Vinci tools has been designed and fabricated with the additional ability of providing information for haptic feedback. This arm was developed as a research platform for developing and evaluating approaches to telesurgery, including various haptic mappings between master and slave and evaluating the effects of latency.

  18. Viscoelastic properties of elastomeric materials for O-ring applications

    NASA Technical Reports Server (NTRS)

    Bower, Mark V.

    1989-01-01

    Redesign of the Space Shuttle Solid Rocket Booster necessitated re-evaluation of the material used in the field joint O-ring seals. This research project was established to determine the viscoelastic characteristics of five candidate materials. The five materials are: two fluorocarbon compounds, two nitrile compounds, and a silicon compound. The materials were tested in a uniaxial compression test to determine the characteristic relaxation functions. These tests were performed at five different temperatures. A master material curve was developed for each material from the experimental data. The results of this study are compared to tensile relaxation tests. Application of these results to the design analysis is discussed in detail.

  19. BOKASUN: A fast and precise numerical program to calculate the Master Integrals of the two-loop sunrise diagrams

    NASA Astrophysics Data System (ADS)

    Caffo, Michele; Czyż, Henryk; Gunia, Michał; Remiddi, Ettore

    2009-03-01

    We present the program BOKASUN for fast and precise evaluation of the Master Integrals of the two-loop self-mass sunrise diagram for arbitrary values of the internal masses and the external four-momentum. We use a combination of two methods: a Bernoulli accelerated series expansion and a Runge-Kutta numerical solution of a system of linear differential equations. Program summaryProgram title: BOKASUN Catalogue identifier: AECG_v1_0 Program summary URL:http://cpc.cs.qub.ac.uk/summaries/AECG_v1_0.html Program obtainable from: CPC Program Library, Queen's University, Belfast, N. Ireland Licensing provisions: Standard CPC licence, http://cpc.cs.qub.ac.uk/licence/licence.html No. of lines in distributed program, including test data, etc.: 9404 No. of bytes in distributed program, including test data, etc.: 104 123 Distribution format: tar.gz Programming language: FORTRAN77 Computer: Any computer with a Fortran compiler accepting FORTRAN77 standard. Tested on various PC's with LINUX Operating system: LINUX RAM: 120 kbytes Classification: 4.4 Nature of problem: Any integral arising in the evaluation of the two-loop sunrise Feynman diagram can be expressed in terms of a given set of Master Integrals, which should be calculated numerically. The program provides a fast and precise evaluation method of the Master Integrals for arbitrary (but not vanishing) masses and arbitrary value of the external momentum. Solution method: The integrals depend on three internal masses and the external momentum squared p. The method is a combination of an accelerated expansion in 1/p in its (pretty large!) region of fast convergence and of a Runge-Kutta numerical solution of a system of linear differential equations. Running time: To obtain 4 Master Integrals on PC with 2 GHz processor it takes 3 μs for series expansion with pre-calculated coefficients, 80 μs for series expansion without pre-calculated coefficients, from a few seconds up to a few minutes for Runge-Kutta method (depending on the required accuracy and the values of the physical parameters).

  20. A semiparametric separation curve approach for comparing correlated ROC data from multiple markers

    PubMed Central

    Tang, Liansheng Larry; Zhou, Xiao-Hua

    2012-01-01

    In this article we propose a separation curve method to identify the range of false positive rates for which two ROC curves differ or one ROC curve is superior to the other. Our method is based on a general multivariate ROC curve model, including interaction terms between discrete covariates and false positive rates. It is applicable with most existing ROC curve models. Furthermore, we introduce a semiparametric least squares ROC estimator and apply the estimator to the separation curve method. We derive a sandwich estimator for the covariance matrix of the semiparametric estimator. We illustrate the application of our separation curve method through two real life examples. PMID:23074360

  1. Quantitative Real-Time PCR using the Thermo Scientific Solaris qPCR Assay

    PubMed Central

    Ogrean, Christy; Jackson, Ben; Covino, James

    2010-01-01

    The Solaris qPCR Gene Expression Assay is a novel type of primer/probe set, designed to simplify the qPCR process while maintaining the sensitivity and accuracy of the assay. These primer/probe sets are pre-designed to >98% of the human and mouse genomes and feature significant improvements from previously available technologies. These improvements were made possible by virtue of a novel design algorithm, developed by Thermo Scientific bioinformatics experts. Several convenient features have been incorporated into the Solaris qPCR Assay to streamline the process of performing quantitative real-time PCR. First, the protocol is similar to commonly employed alternatives, so the methods used during qPCR are likely to be familiar. Second, the master mix is blue, which makes setting the qPCR reactions easier to track. Third, the thermal cycling conditions are the same for all assays (genes), making it possible to run many samples at a time and reducing the potential for error. Finally, the probe and primer sequence information are provided, simplifying the publication process. Here, we demonstrate how to obtain the appropriate Solaris reagents using the GENEius product search feature found on the ordering web site (www.thermo.com/solaris) and how to use the Solaris reagents for performing qPCR using the standard curve method. PMID:20567213

  2. Symposia in undergraduate medical education: tailoring training in competencies to students' needs.

    PubMed

    Reefman, Karin; Daelmans, Hester E M; Klumpers, Ursula M H; Croiset, Gerda

    2017-12-01

    In mastering competencies, it is a challenge to create training sessions which acknowledge individual students' needs and are logistically feasible in the medical master's program. Symposia were implemented in the medical master's program to provide knowledge and training of skills in a number of topics, providing a positive contribution to students' competencies and personal development. Each symposium contained a morning and afternoon program, structured around medical and societal themes addressing various competencies and covering current national and international events. Alternating interactive teaching methods were used. Students were asked to rate each daypart program on a 5-point Likert scale in terms of both teaching methods and content, and to comment on the best aspects of the symposium as well as areas for improvement. Scores higher than 3.5 were interpreted as a predominantly favourable outcome. In 2016, 10 symposia were organized with an average of 108 attendees and a response rate of 63% (1,366 completed questionnaires). Mean overall scores on 'teaching methods' and 'usefulness for professional development' were 3.8 and 3.7, respectively. The overall results corresponded with a high level of student appreciation. Symposia offer a podium for training students in subject matter and competencies that is greatly appreciated. Using alternating interactive teaching methods, symposia are structured around medical and societal themes and adjusted to the latest developments and current events in healthcare. By allowing students to select the symposia they would like to participate in, a tailor-made medical master's program in competencies is created.

  3. The average receiver operating characteristic curve in multireader multicase imaging studies

    PubMed Central

    Samuelson, F W

    2014-01-01

    Objective: In multireader, multicase (MRMC) receiver operating characteristic (ROC) studies for evaluating medical imaging systems, the area under the ROC curve (AUC) is often used as a summary metric. Owing to the limitations of AUC, plotting the average ROC curve to accompany the rigorous statistical inference on AUC is recommended. The objective of this article is to investigate methods for generating the average ROC curve from ROC curves of individual readers. Methods: We present both a non-parametric method and a parametric method for averaging ROC curves that produce a ROC curve, the area under which is equal to the average AUC of individual readers (a property we call area preserving). We use hypothetical examples, simulated data and a real-world imaging data set to illustrate these methods and their properties. Results: We show that our proposed methods are area preserving. We also show that the method of averaging the ROC parameters, either the conventional bi-normal parameters (a, b) or the proper bi-normal parameters (c, da), is generally not area preserving and may produce a ROC curve that is intuitively not an average of multiple curves. Conclusion: Our proposed methods are useful for making plots of average ROC curves in MRMC studies as a companion to the rigorous statistical inference on the AUC end point. The software implementing these methods is freely available from the authors. Advances in knowledge: Methods for generating the average ROC curve in MRMC ROC studies are formally investigated. The area-preserving criterion we defined is useful to evaluate such methods. PMID:24884728

  4. The maximum growth rate of life on Earth

    NASA Astrophysics Data System (ADS)

    Corkrey, Ross; McMeekin, Tom A.; Bowman, John P.; Olley, June; Ratkowsky, David

    2018-01-01

    Life on Earth spans a range of temperatures and exhibits biological growth rates that are temperature dependent. While the observation that growth rates are temperature dependent is well known, we have recently shown that the statistical distribution of specific growth rates for life on Earth is a function of temperature (Corkrey et al., 2016). The maximum rates of growth of all life have a distinct limit, even when grown under optimal conditions, and which vary predictably with temperature. We term this distribution of growth rates the biokinetic spectrum for temperature (BKST). The BKST possibly arises from a trade-off between catalytic activity and stability of enzymes involved in a rate-limiting Master Reaction System (MRS) within the cell. We develop a method to extrapolate quantile curves for the BKST to obtain the posterior probability of the maximum rate of growth of any form of life on Earth. The maximum rate curve conforms to the observed data except below 0°C and above 100°C where the predicted value may be positively biased. The deviation below 0°C may arise from the bulk properties of water, while the degradation of biomolecules may be important above 100°C. The BKST has potential application in astrobiology by providing an estimate of the maximum possible growth rate attainable by terrestrial life and perhaps life elsewhere. We suggest that the area under the maximum growth rate curve and the peak rate may be useful characteristics in considerations of habitability. The BKST can serve as a diagnostic for unusual life, such as second biogenesis or non-terrestrial life. Since the MRS must have been heavily conserved the BKST may contain evolutionary relics. The BKST can serve as a signature summarizing the nature of life in environments beyond Earth, or to characterize species arising from a second biogenesis on Earth.

  5. Repeatability of Ophtha Top topography and comparison with IOL-Master and LenstarLS900 in cataract patients

    PubMed Central

    Yu, Sha-Sha; Song, Hui; Tang, Xin

    2017-01-01

    AIM To determine the repeatability of Ophtha Top topography and assess the consistency with intraocular lens (IOL)-Master and LenstarLS900 (Lenstar) in measuring corneal parameters among cataract patients. METHODS Totally 125 eyes were enrolled. Corneas were successively measured with Ophtha Top, IOL-Master and Lenstar at least three times. The flattest meridian power (Kf), the steepest meridian power (Ks), mean power (Km), J0 and J45 were recorded. Intra-class correlation coefficients (ICCs), the coefficient of variance (COV), within subject standard deviation (Sw), and test-retest repeatability (2.77Sw) were adopted to determine the repeatability. The 95% limit of agreement (95%LOA) and Bland-Altman plots were used to assess comparability. RESULTS Repeatability of Ophtha Top topography for measuring corneal parameters showed the ICCs were all above 0.93, 2.77Sw was lower than 0.31, and the COV of the Kf and Ks was lower than 0.25. The keratometric readings with Ophtha Top topography were flatter than with the IOL-Master and Lenstar devices, while the Pearson correlation coefficients were over 0.97. The J0 and J45 with Ophtha Top topography were smaller compared with Lenstar and IOL-Master, while was comparable between Lenstar and IOL-Master. CONCLUSION Ophtha Top topography shows excellent repeatability for measuring corneal parameters. However, differences between the Ophtha TOP topography and Lenstar, IOL-Master both in cornea curvature and the astigmatism should be noted clinically. PMID:29181314

  6. A Comparison of Classroom and Online Asynchronous Problem-Based Learning for Students Undertaking Statistics Training as Part of a Public Health Masters Degree

    ERIC Educational Resources Information Center

    de Jong, N.; Verstegen, D. M. L.; Tan, F. E. S.; O'Connor, S. J.

    2013-01-01

    This case-study compared traditional, face-to-face classroom-based teaching with asynchronous online learning and teaching methods in two sets of students undertaking a problem-based learning module in the multilevel and exploratory factor analysis of longitudinal data as part of a Masters degree in Public Health at Maastricht University. Students…

  7. Comparison between McMaster and Mini-FLOTAC methods for the enumeration of Eimeria maxima oocysts in poultry excreta.

    PubMed

    Bortoluzzi, C; Paras, K L; Applegate, T J; Verocai, G G

    2018-04-30

    Monitoring Eimeria shedding has become more important due to the recent restrictions to the use of antibiotics within the poultry industry. Therefore, there is a need for the implementation of more precise and accurate quantitative diagnostic techniques. The objective of this study was to compare the precision and accuracy between the Mini-FLOTAC and the McMaster techniques for quantitative diagnosis of Eimeria maxima oocyst in poultry. Twelve pools of excreta samples of broiler chickens experimentally infected with E. maxima were analyzed for the comparison between Mini-FLOTAC and McMaster technique using, the detection limits (dl) of 23 and 25, respectively. Additionally, six excreta samples were used to compare the precision of different dl (5, 10, 23, and 46) using the Mini-FLOTAC technique. For precision comparisons, five technical replicates of each sample (five replicate slides on one excreta slurry) were read for calculating the mean oocyst per gram of excreta (OPG) count, standard deviation (SD), coefficient of variation (CV), and precision of both aforementioned comparisons. To compare accuracy between the methods (McMaster, and Mini-FLOTAC dl 5 and 23), excreta from uninfected chickens was spiked with 100, 500, 1,000, 5,000, or 10,000 OPG; additional samples remained unspiked (negative control). For each spiking level, three samples were read in triplicate, totaling nine reads per spiking level per technique. Data were transformed using log10 to obtain normality and homogeneity of variances. A significant correlation (R = 0.74; p = 0.006) was observed between the mean OPG of the McMaster dl 25 and the Mini-FLOTAC dl 23. Mean OPG, CV, SD, and precision were not statistically different between the McMaster dl 25 and Mini-FLOTAC dl 23. Despite the absence of statistical difference (p > 0.05), Mini-FLOTAC dl 5 showed a numerically lower SD and CV than Mini-FLOTAC dl 23. The Pearson correlation coefficient revealed significant and positive correlation among the four dl (p ≤ 0.05). In the accuracy study, it was observed that the Mini-FLOTAC dl 5 and 23 were more accurate than the McMaster for 100 OPG, and the Mini-FLOTAC dl 23 had the highest accuracy for 500 OPG. The McMaster and Mini-FLOTAC dl 23 techniques were more accurate than the Mini-FLOTAC dl 5 for 5,000 OPG, and both dl of the Mini-FLOTAC were less accurate for 10,000 OPG counts than the McMaster technique. However, the overall accuracy of the Mini-FLOTAC dl 23 was higher than the McMaster and Mini-FLOTAC dl 5 techniques. Copyright © 2018 Elsevier B.V. All rights reserved.

  8. "Master-Slave" Biological Network Alignment

    NASA Astrophysics Data System (ADS)

    Ferraro, Nicola; Palopoli, Luigi; Panni, Simona; Rombo, Simona E.

    Performing global alignment between protein-protein interaction (PPI) networks of different organisms is important to infer knowledge about conservation across species. Known methods that perform this task operate symmetrically, that is to say, they do not assign a distinct role to the input PPI networks. However, in most cases, the input networks are indeed distinguishable on the basis of how well the corresponding organism is biologically well-characterized. For well-characterized organisms the associated PPI network supposedly encode in a sound manner all the information about their proteins and associated interactions, which is far from being the case for not well characterized ones. Here the new idea is developed to devise a method for global alignment of PPI networks that in fact exploit differences in the characterization of organisms at hand. We assume that the PPI network (called Master) of the best characterized is used as a fingerprint to guide the alignment process to the second input network (called Slave), so that generated results preferably retain the structural characteristics of the Master (and using the Slave) network. We tested our method showing that the results it returns are biologically relevant.

  9. ABC Assay: Method Development and Application to Quantify the Role of Three DWV Master Variants in Overwinter Colony Losses of European Honey Bees

    PubMed Central

    Kevill, Jessica L.; Highfield, Andrea; Mordecai, Gideon J.; Schroeder, Declan C.

    2017-01-01

    Deformed wing virus (DWV) is one of the most prevalent honey bee viral pathogens in the world. Typical of many RNA viruses, DWV is a quasi-species, which is comprised of a large number of different variants, currently consisting of three master variants: Type A, B, and C. Little is known about the impact of each variant or combinations of variants upon the biology of individual hosts. Therefore, we have developed a new set of master variant-specific DWV primers and a set of standards that allow for the quantification of each of the master variants. Competitive reverse transcriptase polymerase chain reaction (RT-PCR) experimental design confirms that each new DWV primer set is specific to the retrospective master variant. The sensitivity of the ABC assay is dependent on whether DNA or RNA is used as the template and whether other master variants are present in the sample. Comparison of the overall proportions of each master variant within a sample of known diversity, as confirmed by next-generation sequence (NGS) data, validates the efficiency of the ABC assay. The ABC assay was used on archived material from a Devon overwintering colony loss (OCL) 2006–2007 study; further implicating DWV type A and, for the first time, possibly C in the untimely collapse of honey bee colonies. Moreover, in this study DWV type B was not associated with OCL. The use of the ABC assay will allow researchers to quickly and cost effectively pre-screen for the presence of DWV master variants in honey bees. PMID:29077069

  10. A task-specific interactive game-based virtual reality rehabilitation system for patients with stroke: a usability test and two clinical experiments

    PubMed Central

    2014-01-01

    Background Virtual reality (VR) is not commonly used in clinical rehabilitation, and commercial VR gaming systems may have mixed effects in patients with stroke. Therefore, we developed RehabMaster™, a task-specific interactive game-based VR system for post-stroke rehabilitation of the upper extremities, and assessed its usability and clinical efficacy. Methods A participatory design and usability tests were carried out for development of RehabMaster with representative user groups. Two clinical trials were then performed. The first was an observational study in which seven patients with chronic stroke received 30 minutes of RehabMaster intervention per day for two weeks. The second was a randomised controlled trial of 16 patients with acute or subacute stroke who received 10 sessions of conventional occupational therapy only (OT-only group) or conventional occupational therapy plus 20 minutes of RehabMaster intervention (RehabMaster + OT group). The Fugl-Meyer Assessment score (FMA), modified Barthel Index (MBI), adverse effects, and drop-out rate were recorded. Results The requirements of a VR system for stroke rehabilitation were established and incorporated into RehabMaster. The reported advantages from the usability tests were improved attention, the immersive flow experience, and individualised intervention. The first clinical trial showed that the RehabMaster intervention improved the FMA (P = .03) and MBI (P = .04) across evaluation times. The second trial revealed that the addition of RehabMaster intervention tended to enhance the improvement in the FMA (P = .07) but did not affect the improvement in the MBI. One patient with chronic stroke left the trial, and no adverse effects were reported. Conclusions The RehabMaster is a feasible and safe VR system for enhancing upper extremity function in patients with stroke. PMID:24597650

  11. Effective use of outcomes data in cardiovascular surgery

    NASA Astrophysics Data System (ADS)

    Yasnoff, William A.; Page, U. S.

    1994-12-01

    We have established the Merged Cardiac Registry (MCR) containing over 100,000 cardiovascular surgery cases from 47 sites in the U.S. and Europe. MCR outcomes data are used by the contributors for clinical quality improvement. A tool for prospective prediction of mortality and stroke for coronary artery bypass graft surgery (83% of the cases), known as RiskMaster, has been developed using a Bayesian model based on 40,819 patients who had their surgery from 1988-92, and tested on 4,244 patients from 1993. In patients with mortality risks of 10% or less (92% of cases), the average risk prediction is identical to the actual 30- day mortality (p > 0.37), while risk is overestimated in higher risk patients. The receiver operating characteristic curve area for mortality prediction is 0.76 +/- 0.02. The RiskMaster prediction tool is now available online or as a standalone software package. MCR data also shows that average mortality risk is identical for a given body surface area regardless of gender. Outcomes data measure the benefits of health care, and are therefore an essential element in cost/benefit analysis. We believe their cost is justified by their use for the rational assessment of treatment alternatives.

  12. How to establish endoscopic submucosal dissection in Western countries.

    PubMed

    Oyama, Tsuneo; Yahagi, Naohisa; Ponchon, Thierry; Kiesslich, Tobias; Berr, Frieder

    2015-10-28

    Endoscopic submucosal dissection (ESD) has been invented in Japan to provide resection for cure of early cancer in the gastrointestinal tract. Professional level of ESD requires excellent staging of early neoplasias with image enhanced endoscopy (IEE) to make correct indications for ESD, and high skills in endoscopic electrosurgical dissection. In Japan, endodiagnostic and endosurgical excellence spread through personal tutoring of skilled endoscopists by the inventors and experts in IEE and ESD. To translocate this expertise to other continents must overcome two fundamental obstacles: (1) inadequate expectations as to the complexity of IEE and ESD; and (2) lack of suitable lesions and master-mentors for ESD trainees. Leading endoscopic mucosal resection-proficient endoscopists must pioneer themselves through the long learning curve to proficient ESD experts. Major referral centers for ESD must arise in Western countries on comparable professional level as in Japan. In the second stage, the upcoming Western experts must commit themselves to teach skilled endoscopists from other referral centers, in order to spread ESD in Western countries. Respect for patients with early gastrointestinal cancer asks for best efforts to learn endoscopic categorization of early neoplasias and skills for ESD based on sustained cooperation with the masters in Japan. The strategy is discussed here.

  13. The Master level optics laboratory at the Institute of Optics

    NASA Astrophysics Data System (ADS)

    Adamson, Per

    2017-08-01

    The master level optics laboratory is a biannual, intensive laboratory course in the fields of geometrical, physical and modern optics. This course is intended for the master level student though Ph.D. advisors which often recommend it to their advisees. The students are required to complete five standard laboratory experiments and an independent project during a semester. The goals of the laboratory experiments are for the students to get hands-on experience setting up optical laboratory equipment, collecting and analyzing data, as well as to communicate key results. The experimental methods, analysis, and results of the standard experiments are submitted in a journal style report, while an oral presentation is given for the independent project.

  14. A comparison of modifications of the McMaster method for the enumeration of Ascaris suum eggs in pig faecal samples.

    PubMed

    Pereckiene, A; Kaziūnaite, V; Vysniauskas, A; Petkevicius, S; Malakauskas, A; Sarkūnas, M; Taylor, M A

    2007-10-21

    The comparative efficacies of seven published McMaster method modifications for faecal egg counting were evaluated on pig faecal samples containing Ascaris suum eggs. Comparisons were made as to the number of samples found to be positive by each of the methods, the total egg counts per gram (EPG) of faeces, the variations in EPG obtained in the samples examined, and the ease of use of each of the methods. Each method was evaluated after the examination of 30 samples of faeces. The positive samples were identified by counting A. suum eggs in one, two and three sections of newly designed McMaster chamber. In the present study compared methods were reported by: I-Henriksen and Aagaard [Henriksen, S.A., Aagaard, K.A., 1976. A simple flotation and McMaster method. Nord. Vet. Med. 28, 392-397]; II-Kassai [Kassai, T., 1999. Veterinary Helminthology. Butterworth-Heinemann, Oxford, 260 pp.]; III and IV-Urquhart et al. [Urquhart, G.M., Armour, J., Duncan, J.L., Dunn, A.M., Jennings, F.W., 1996. Veterinary Parasitology, 2nd ed. Blackwell Science Ltd., Oxford, UK, 307 pp.] (centrifugation and non-centrifugation methods); V and VI-Grønvold [Grønvold, J., 1991. Laboratory diagnoses of helminths common routine methods used in Denmark. In: Nansen, P., Grønvold, J., Bjørn, H. (Eds.), Seminars on Parasitic Problems in Farm Animals Related to Fodder Production and Management. The Estonian Academy of Sciences, Tartu, Estonia, pp. 47-48] (salt solution, and salt and glucose solution); VII-Thienpont et al. [Thienpont, D., Rochette, F., Vanparijs, O.F.J., 1986. Diagnosing Helminthiasis by Coprological Examination. Coprological Examination, 2nd ed. Janssen Research Foundation, Beerse, Belgium, 205 pp.]. The number of positive samples by examining single section ranged from 98.9% (method I), to 51.1% (method VII). Only with methods I and II, there was a 100% positivity in two out of three of the chambers examined, and FEC obtained using these methods were significantly (p<0.01) higher comparing to remaining methods. Mean FEC varied between 243 EPG (method I) and 82 EPG (method IV). Examination of all three chambers resulted in four methods (I, II, V and VI) having 100% sensitivity, while method VII had the lowest 83.3% sensitivity. Mean FEC in this case varied between 239 EPG (method I) and 81 EPG (method IV). Based on the mean FEC for two chambers, an efficiency coefficient (EF) was calculated and equated to 1 for the highest egg count (method I) and 0.87, 0.57, 0.34, 0.53, 0.49 and 0.50 for remaining methods (II-VII), respectively. Efficiency coefficients make it possible not only to recalculate and unify results of faeces examination obtained by any method but also to interpret coproscopical examinations by other authors. Method VII was the easiest and quickest but least sensitive, and method I the most complex but most sensitive. Examining two or three sections of the McMaster chamber resulted in increased sensitivity for all methods.

  15. An online survey of chiropractors' opinions of continuing education

    PubMed Central

    Stuber, Kent J; Grod, Jaroslaw P; Smith, Dean L; Powers, Paul

    2005-01-01

    Background Continuing Education (CE) for chiropractors is mandatory for licensure in most North American jurisdictions. Numerous chiropractic colleges have begun collaborating with universities to offer master's degree programs. Distance education master's degree programs may be desirable to allow full-time practicing doctors to further their post-graduate education. The present survey sought to answer three questions. First, what is the level of satisfaction of chiropractors with their continuing education? Second, what is the level of interest of chiropractors in online master's degree programs? Lastly, what is the response rate of chiropractors to an online survey? Methods An online survey consisting of 22 multiple choice questions was e-mailed to 1000 chiropractors randomly selected from the mailing list of an online chiropractic newsletter. Upon completion of the questionnaire, participants' answers were saved on a secure site. Data analysis included evaluation of the demographic characteristics of the respondents, their opinions of and patterns of taking CE including online education, preferred learning formats, and their interest in proposed online master's degree programs. A survey response rate was determined. Results Nearly 86% of respondents felt their previously completed CE courses were either somewhat or extremely satisfactory. Over ninety percent of respondents who had completed online or distance CE coursesfound them to be somewhat or extremelysatisfactory. Almost half the respondents indicated that they most preferred online distance learning, while 34.08% most preferred face-to-face interaction. Fifty-three percent of respondents indicated an interest in starting a master's degree program; however 70.46% of respondents were interested in an online master's degree program that would offer CE credit. A response rate of 35.8% was obtained. Conclusion Satisfaction among chiropractors with CE programs is high. The notion of completing a part-time online master's degree (or online combined with face-to-face interaction) appears to be popular among respondents, with a M.Sc. in Chiropractic Sciences being the most popular of those mentioned. Online surveys are a viable method of obtaining opinion in a cost and time efficient manner; there are some sources of bias involved in this type of research, and numerous steps need to be taken to obtain a suitable response rate. PMID:16242035

  16. A Comparison between National and Transnational Students' Access of Online Learning Support Materials and Experience of Technical Difficulties on a Fully Online Distance Learning Master of Public Health Programme

    ERIC Educational Resources Information Center

    Gemmell, Isla; Harrison, Roger

    2017-01-01

    Online distance learning (ODL) is now recognised as a mainstream teaching method for undergraduate and postgraduate students around the world. However, differences in learner characteristics such as help-seeking behaviour between transnational students and home students may impact on student attainment. 64 students undertaking an online master of…

  17. Algebraic aspects of the driven dynamics in the density operator and correlation functions calculation for multi-level open quantum systems

    NASA Astrophysics Data System (ADS)

    Bogolubov, Nikolai N.; Soldatov, Andrey V.

    2017-12-01

    Exact and approximate master equations were derived by the projection operator method for the reduced statistical operator of a multi-level quantum system with finite number N of quantum eigenstates interacting with arbitrary external classical fields and dissipative environment simultaneously. It was shown that the structure of these equations can be simplified significantly if the free Hamiltonian driven dynamics of an arbitrary quantum multi-level system under the influence of the external driving fields as well as its Markovian and non-Markovian evolution, stipulated by the interaction with the environment, are described in terms of the SU(N) algebra representation. As a consequence, efficient numerical methods can be developed and employed to analyze these master equations for real problems in various fields of theoretical and applied physics. It was also shown that literally the same master equations hold not only for the reduced density operator but also for arbitrary nonequilibrium multi-time correlation functions as well under the only assumption that the system and the environment are uncorrelated at some initial moment of time. A calculational scheme was proposed to account for these lost correlations in a regular perturbative way, thus providing additional computable terms to the correspondent master equations for the correlation functions.

  18. Simplified method for creating a density-absorbed dose calibration curve for the low dose range from Gafchromic EBT3 film.

    PubMed

    Gotanda, Tatsuhiro; Katsuda, Toshizo; Gotanda, Rumi; Kuwano, Tadao; Akagawa, Takuya; Tanki, Nobuyoshi; Tabuchi, Akihiko; Shimono, Tetsunori; Kawaji, Yasuyuki

    2016-01-01

    Radiochromic film dosimeters have a disadvantage in comparison with an ionization chamber in that the dosimetry process is time-consuming for creating a density-absorbed dose calibration curve. The purpose of this study was the development of a simplified method of creating a density-absorbed dose calibration curve from radiochromic film within a short time. This simplified method was performed using Gafchromic EBT3 film with a low energy dependence and step-shaped Al filter. The simplified method was compared with the standard method. The density-absorbed dose calibration curves created using the simplified and standard methods exhibited approximately similar straight lines, and the gradients of the density-absorbed dose calibration curves were -32.336 and -33.746, respectively. The simplified method can obtain calibration curves within a much shorter time compared to the standard method. It is considered that the simplified method for EBT3 film offers a more time-efficient means of determining the density-absorbed dose calibration curve within a low absorbed dose range such as the diagnostic range.

  19. Simplified method for creating a density-absorbed dose calibration curve for the low dose range from Gafchromic EBT3 film

    PubMed Central

    Gotanda, Tatsuhiro; Katsuda, Toshizo; Gotanda, Rumi; Kuwano, Tadao; Akagawa, Takuya; Tanki, Nobuyoshi; Tabuchi, Akihiko; Shimono, Tetsunori; Kawaji, Yasuyuki

    2016-01-01

    Radiochromic film dosimeters have a disadvantage in comparison with an ionization chamber in that the dosimetry process is time-consuming for creating a density-absorbed dose calibration curve. The purpose of this study was the development of a simplified method of creating a density-absorbed dose calibration curve from radiochromic film within a short time. This simplified method was performed using Gafchromic EBT3 film with a low energy dependence and step-shaped Al filter. The simplified method was compared with the standard method. The density-absorbed dose calibration curves created using the simplified and standard methods exhibited approximately similar straight lines, and the gradients of the density-absorbed dose calibration curves were −32.336 and −33.746, respectively. The simplified method can obtain calibration curves within a much shorter time compared to the standard method. It is considered that the simplified method for EBT3 film offers a more time-efficient means of determining the density-absorbed dose calibration curve within a low absorbed dose range such as the diagnostic range. PMID:28144120

  20. High-fidelity bilateral teleoperation systems and the effect of multimodal haptics.

    PubMed

    Tavakoli, Mahdi; Aziminejad, Arash; Patel, Rajni V; Moallem, Mehrdad

    2007-12-01

    In master-slave teleoperation applications that deal with a delicate and sensitive environment, it is important to provide haptic feedback of slave/environment interactions to the user's hand as it improves task performance and teleoperation transparency (fidelity), which is the extent of telepresence of the remote environment available to the user through the master-slave system. For haptic teleoperation, in addition to a haptics-capable master interface, often one or more force sensors are also used, which warrant new bilateral control architectures while increasing the cost and the complexity of the teleoperation system. In this paper, we investigate the added benefits of using force sensors that measure hand/master and slave/environment interactions and of utilizing local feedback loops on the teleoperation transparency. We compare the two-channel and the four-channel bilateral control systems in terms of stability and transparency, and study the stability and performance robustness of the four-channel method against nonidealities that arise during bilateral control implementation, which include master-slave communication latency and changes in the environment dynamics. The next issue addressed in the paper deals with the case where the master interface is not haptics capable, but the slave is equipped with a force sensor. In the context of robotics-assisted soft-tissue surgical applications, we explore through human factors experiments whether slave/environment force measurements can be of any help with regard to improving task performance. The last problem we study is whether slave/environment force information, with and without haptic capability in the master interface, can help improve outcomes under degraded visual conditions.

  1. Shock melting method to determine melting curve by molecular dynamics: Cu, Pd, and Al

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Liu, Zhong-Li, E-mail: zl.liu@163.com; Zhang, Xiu-Lu; Cai, Ling-Cang

    A melting simulation method, the shock melting (SM) method, is proposed and proved to be able to determine the melting curves of materials accurately and efficiently. The SM method, which is based on the multi-scale shock technique, determines melting curves by preheating and/or prepressurizing materials before shock. This strategy was extensively verified using both classical and ab initio molecular dynamics (MD). First, the SM method yielded the same satisfactory melting curve of Cu with only 360 atoms using classical MD, compared to the results from the Z-method and the two-phase coexistence method. Then, it also produced a satisfactory melting curvemore » of Pd with only 756 atoms. Finally, the SM method combined with ab initio MD cheaply achieved a good melting curve of Al with only 180 atoms, which agrees well with the experimental data and the calculated results from other methods. It turned out that the SM method is an alternative efficient method for calculating the melting curves of materials.« less

  2. Effect of length and location of edentulous area on the accuracy of prosthetic treatment plan incorporation into cone-beam computed tomography scans.

    PubMed

    Jamjoom, Faris Z; Kim, Do-Gyoon; Lee, Damian J; McGlumphy, Edwin A; Yilmaz, Burak

    2018-02-05

    Effects of length and location of the edentulous area on the accuracy of prosthetic treatment plan incorporation into cone-beam computed tomography (CBCT) scans has not been investigated. To evaluate the effect of length and location of the edentulous area on the accuracy of prosthetic treatment plan incorporation into CBCT scans using different methods. Direct digital scans of a completely dentate master model with removable radiopaque teeth were made using an intraoral scanner, and digital scans of stone duplicates of the master model were made using a laboratory scanner. Specific teeth were removed to simulate different clinical situations and their CBCT scans were made. Surface scans were registered onto the CBCT scans. Radiographic templates for each clinical situation were also fabricated and used during CBCT scans of the master models. Using metrology software, three-dimensional (3D) deviation was measured on standard tesselation language (STL) files created from the CBCT scans against an STL file of the master model created from a CBCT scan. Statistical analysis was done using the MIXED procedure in a statistical software and Tukey HSD test (α =.05). The interaction between location and method was significant (P = .009). Location had no significant effect on registration methods (P > .05), but on the radiographic templates (P = .011). Length of the edentulous area did not have any significant effect (P > .05). Accuracy of digital image registration methods was similar and higher than that of radiographic templates in all clinical situations. Tooth-bound radiographic templates were significantly more accurate than the free-end templates. The results of this study suggest using image registration instead of radiographic templates when planning dental implants, particularly in free-end situations. © 2018 Wiley Periodicals, Inc.

  3. Injection locking method for Raman beams in atom interferometer

    NASA Astrophysics Data System (ADS)

    Zi, Fei; Deng, Jianing; Zeng, Daji; Li, Tong; Sun, Mingli; Zhang, Xian; Huang, Kaikai; Lu, Xuanhui

    2018-03-01

    We present a novel method to generate two phase-locked beams with a frequency offset of 6.834 GHz. The output of the master laser is firstly modulated by an electric optical modulator (EOM), and then further injected into an Extended Cavity Diode Lasers (ECDL) which is used to filter out the unwanted mode and amplify the laser power. By locking to the first-order lower sideband of the modulated master laser, the average variance of the phase fluctuations is 5.6 x 10-3 rad2 , which implies phase coherence of 99.44% between the master laser and the slave ECDL. The line width of the beat notes is less than 1Hz. For the long term stability, with the delicate design of the electronic controller in ECDL, the phase coherence of the two laser beams can be stabilized over 200 hours without any adjustment. The Raman system is applicable for gravity detection with a preliminary sensitivity Δg/g of 4.5 x 10-7 for interrogation time of 1500 s.

  4. Soft Expansion of Double-Real-Virtual Corrections to Higgs Production at N$^3$LO

    DOE PAGES

    Anastasiou, Charalampos; Duhr, Claude; Dulat, Falko; ...

    2015-05-15

    We present methods to compute higher orders in the threshold expansion for the one-loop production of a Higgs boson in association with two partons at hadron colliders. This process contributes to the N 3LO Higgs production cross section beyond the soft-virtual approximation. We use reverse unitarity to expand the phase-space integrals in the small kinematic parameters and to reduce the coefficients of the expansion to a small set of master integrals. We describe two methods for the calculation of the master integrals. The first was introduced for the calculation of the soft triple-real radiation relevant to N 3LO Higgs production.more » The second uses a particular factorization of the three body phase-space measure and the knowledge of the scaling properties of the integral itself. Our result is presented as a Laurent expansion in the dimensional regulator, although some of the master integrals are computed to all orders in this parameter.« less

  5. Surgeons’ and residents’ double-gloving practices at 2 teaching hospitals in Ontario

    PubMed Central

    Haines, Ted; Stringer, Bernadette; Herring, Jeremy; Thoma, Achilleas; Harris, Kenneth A.

    2011-01-01

    Background Surgeons and residents are at increased risk of exposure to blood-borne pathogens owing to percutaneous injury (PI) and contamination. One method known to reduce risk is double-gloving (DG) during surgery. Methods All surgeons and residents affiliated with the University of Western Ontario (UWO) and McMaster University in 2005 were asked to participate in a Web-based survey. The survey asked respondents their specialty, the number of operations they participated in per week, their age and sex, the proportion of surgeries in which they double-gloved (DG in ≥ 75% surgeries was considered to be routine), and the average number of PIs they sustained per year and whether or not they reported them to an employee health service. Results In total, 155 of 331 (47%) eligible surgeons and residents responded; response rates for UWO and McMaster surgeons were 50% and 39%, respectively, and for UWO and McMaster residents, they were 52% and 47%, respectively. A total of 43% of surgeons and residents reported routine DG; 50% from McMaster and 36% from UWO. Using logistic regression to simultaneously adjust for participant characteristics, we confirmed that DG was more frequent at McMaster than at UWO, with an odds ratio of 3.32 (95% confidence interval 1.35–8.17). Surgeons and residents reported an average of 3.3 surgical PIs per year (2.2 among McMaster participants and 4.5 among UWO participants). Of the 77% who reported at least 1 injury/year, 67% stated that they had not reported it to an employee health service. Conclusion Percutaneous injuries occur frequently during surgery, yet routine DG, an effective means of reducing risk, was carried out by less than half of the surgeons and residents participating in this study. This highlights the need for a more concerted and broad-based approach to increase the use of a measure that is effective, inexpensive and easily carried out. PMID:21251417

  6. Extensions to decision curve analysis, a novel method for evaluating diagnostic tests, prediction models and molecular markers

    PubMed Central

    Vickers, Andrew J; Cronin, Angel M; Elkin, Elena B; Gonen, Mithat

    2008-01-01

    Background Decision curve analysis is a novel method for evaluating diagnostic tests, prediction models and molecular markers. It combines the mathematical simplicity of accuracy measures, such as sensitivity and specificity, with the clinical applicability of decision analytic approaches. Most critically, decision curve analysis can be applied directly to a data set, and does not require the sort of external data on costs, benefits and preferences typically required by traditional decision analytic techniques. Methods In this paper we present several extensions to decision curve analysis including correction for overfit, confidence intervals, application to censored data (including competing risk) and calculation of decision curves directly from predicted probabilities. All of these extensions are based on straightforward methods that have previously been described in the literature for application to analogous statistical techniques. Results Simulation studies showed that repeated 10-fold crossvalidation provided the best method for correcting a decision curve for overfit. The method for applying decision curves to censored data had little bias and coverage was excellent; for competing risk, decision curves were appropriately affected by the incidence of the competing risk and the association between the competing risk and the predictor of interest. Calculation of decision curves directly from predicted probabilities led to a smoothing of the decision curve. Conclusion Decision curve analysis can be easily extended to many of the applications common to performance measures for prediction models. Software to implement decision curve analysis is provided. PMID:19036144

  7. Transformation-invariant and nonparametric monotone smooth estimation of ROC curves.

    PubMed

    Du, Pang; Tang, Liansheng

    2009-01-30

    When a new diagnostic test is developed, it is of interest to evaluate its accuracy in distinguishing diseased subjects from non-diseased subjects. The accuracy of the test is often evaluated by receiver operating characteristic (ROC) curves. Smooth ROC estimates are often preferable for continuous test results when the underlying ROC curves are in fact continuous. Nonparametric and parametric methods have been proposed by various authors to obtain smooth ROC curve estimates. However, there are certain drawbacks with the existing methods. Parametric methods need specific model assumptions. Nonparametric methods do not always satisfy the inherent properties of the ROC curves, such as monotonicity and transformation invariance. In this paper we propose a monotone spline approach to obtain smooth monotone ROC curves. Our method ensures important inherent properties of the underlying ROC curves, which include monotonicity, transformation invariance, and boundary constraints. We compare the finite sample performance of the newly proposed ROC method with other ROC smoothing methods in large-scale simulation studies. We illustrate our method through a real life example. Copyright (c) 2008 John Wiley & Sons, Ltd.

  8. Assessing Technical Inefficiency in Private, Not-For-Profit, Bachelor's and Master's Universities in the United States Using Stochastic Frontier Estimation

    ERIC Educational Resources Information Center

    Refenes, James L.

    2017-01-01

    This research explored the technical inefficiency of 813 private, not-for-profit, four-year, bachelor's and master's colleges and universities in the U.S. using data from 2006 to 2011. The goal of the study was to describe and explain the level of technical inefficiency in this group of institutions that can be identified using a (SFE) method and…

  9. Professional Master's degree in Nursing: knowledge production and challenges

    PubMed Central

    Munari, Denize Bouttelet; Parada, Cristina Maria Garcia de Lima; Gelbcke, Francine de Lima; Silvino, Zenith Rosa; Ribeiro, Luana Cássia Miranda; Scochi, Carmen Gracinda Silvan

    2014-01-01

    Objective to analyze the production of knowledge resulting from the professional master's degree programs in Nursing and to reflect about their perspectives for the area. Method descriptive and analytical study. Data collected from the dissertations of three educational institutions that graduated students in programs of professional master's degree in Nursing between 2006 and 2012 were included. Results most of the 127 course completion studies analyzed were developed within hospital contexts; there was a focus on the organizational and healthcare areas, in the research fields care process and management, and predominance of qualitative studies. There are various products resulting from the course completion studies: evaluation of services/healthcare programs and development of processes, care or educational protocols. Conclusion the programs of professional master's degree in Nursing, which are undergoing a consolidation stage, have recent production under development and there is a gap in the creation of hard technologies and innovation. They are essential for the development of innovative professional practices that articulate the healthcare and educational areas. PMID:26107826

  10. Communication: Fast dynamics perspective on the breakdown of the Stokes-Einstein law in fragile glassformers

    NASA Astrophysics Data System (ADS)

    Puosi, F.; Pasturel, A.; Jakse, N.; Leporini, D.

    2018-04-01

    The breakdown of the Stokes-Einstein (SE) law in fragile glassformers is examined by Molecular-Dynamics simulations of atomic liquids and polymers and consideration of the experimental data concerning the archetypical ortho-terphenyl glassformer. All the four systems comply with the universal scaling between the viscosity (or the structural relaxation) and the Debye-Waller factor ⟨u2⟩, the mean square amplitude of the particle rattling in the cage formed by the surrounding neighbors. It is found that the SE breakdown is scaled in a master curve by a reduced ⟨u2⟩. Two approximated expressions of the latter, with no and one adjustable parameter, respectively, are derived.

  11. Durability of base courses with mineral-cement-emulsion mixes (MCEM)

    NASA Astrophysics Data System (ADS)

    Kukiełka, J.; Sybilski, D.

    2018-05-01

    Base courses with mineral-cement-emulsion mixes (MCEM) have been the subject of research, surveys and development of e.g. new requirements included in the Guidelines of 2014 [15]. In this paper the results of sample test and survey of road sections, assessment of transverse cracks and load-bearing capacity with FWD after 13 years of exploitation are presented. On the MCEM samples the following tests were carried out: resilient modulus using NAT, complex stiffness modulus (E*), phase shift angle at various temperatures and loading frequencies thereby obtaining master curves, fatigue life and low-temperature resistance by identifying the tensile stress restrained (TSRST) which allowed for general assessment of constructed base courses.

  12. Tensile properties of AZ11A-0 magnesium-alloy sheet under rapid-heating and constant temperature

    NASA Technical Reports Server (NTRS)

    Kurg, Ivo M

    1956-01-01

    Specimens of AZ31A-0 magnesium alloy sheet were heated to rupture at nominal rates of 0.2 F to 100 F per second under constant tensile load conditions. The data are presented and compared with the results of conventional tensile stress-strain tests at elevated temperatures after 1.2-hour exposure. A temperature-rate parameter was used to construct master curves from which stresses and temperatures for yield and rupture can be predicted under rapid-heating conditions. A comparison of the elevated-temperature tensile properties of AZ31A-0 and HK31XA-H24 magnesium-alloy sheet under both constant-temperature and rapid-heating conditions is included.

  13. Impedance spectroscopic characterization of Sm2O3 containing lithium borate glasses.

    PubMed

    Ramteke, D D; Gedam, R S

    2014-12-10

    27.5 Li2O-(72.5-X) B2O3-X Sm2O3 (X=0.5, 1, 1.5 and 2) were prepared by conventional melt quench technique. Impedance spectroscopy (IS) is used to study the electrical properties of these prepared glasses. Modulus formalism is introduced to study relaxation behaviour of these glasses. Scaling model shows the good overlap of data on single master curve which suggests that conduction mechanism in these glasses is compositional dependent. Variation of dielectric constant and dielectric loss with the addition of Sm2O3 and frequency are discussed here. Copyright © 2014 Elsevier B.V. All rights reserved.

  14. Telegraph noise in Markovian master equation for electron transport through molecular junctions

    NASA Astrophysics Data System (ADS)

    Kosov, Daniel S.

    2018-05-01

    We present a theoretical approach to solve the Markovian master equation for quantum transport with stochastic telegraph noise. Considering probabilities as functionals of a random telegraph process, we use Novikov's functional method to convert the stochastic master equation to a set of deterministic differential equations. The equations are then solved in the Laplace space, and the expression for the probability vector averaged over the ensemble of realisations of the stochastic process is obtained. We apply the theory to study the manifestations of telegraph noise in the transport properties of molecular junctions. We consider the quantum electron transport in a resonant-level molecule as well as polaronic regime transport in a molecular junction with electron-vibration interaction.

  15. [Tutorial functions in 1st level nursing masters: cognitive study].

    PubMed

    Sarli, Maria Pompea; Burrai, Francesco; Cicolini, Giancarlo

    2009-01-01

    Tutorial functions are becoming increasingly more respondent to the requirements of student-based training. On the basis of national and international experiences, some active learning methods seem to be suitable for tutoring. Both basic and post-basic training can be directed towards satisfying the requirements of a society that is continually changing , forming professionals who are able to guarantee and maintain suitable levels of skill.In this study the results of a cognitive study, performed in various Italian universities where Masters in Nursing have already been implemented, are described. In particular, these results have shown the need for tutorial teaching methods that actively involve students in the training process.

  16. A stage-normalized function for the synthesis of stage-discharge relations for the Colorado River in Grand Canyon, Arizona

    USGS Publications Warehouse

    Wiele, Stephen M.; Torizzo, Margaret

    2003-01-01

    A method was developed to construct stage-discharge rating curves for the Colorado River in Grand Canyon, Arizona, using two stage-discharge pairs and a stage-normalized rating curve. Stage-discharge rating curves formulated with the stage-normalized curve method are compared to (1) stage-discharge rating curves for six temporary stage gages and two streamflow-gaging stations developed by combining stage records with modeled unsteady flow; (2) stage-discharge rating curves developed from stage records and discharge measurements at three streamflow-gaging stations; and (3) stages surveyed at known discharges at the Northern Arizona Sand Bar Studies sites. The stage-normalized curve method shows good agreement with field data when the discharges used in the construction of the rating curves are at least 200 cubic meters per second apart. Predictions of stage using the stage-normalized curve method are also compared to predictions of stage from a steady-flow model.

  17. Technique Incorporating Cooling & Contraction / Expansion Analysis to Illustrate Shrinkage Tendency in Cast Irons

    NASA Astrophysics Data System (ADS)

    Stan, S.; Chisamera, M.; Riposan, I.; Neacsu, L.; Cojocaru, A. M.; Stan, I.

    2017-06-01

    With the more widespread adoption of thermal analysis testing, thermal analysis data have become an indicator of cast iron quality. The cooling curve and its first derivative display patterns that can be used to predict the characteristics of a cast iron. An experimental device was developed with a technique to simultaneously evaluate cooling curves and expansion or contraction of cast metals during solidification. Its application is illustrated with results on shrinkage tendency of ductile iron treated with FeSiMgRECa master alloy and inoculated with FeSi based alloys, as affected by mould rigidity (green sand and resin sand moulds). Undercooling at the end of solidification relative to the metastable (carbidic) equilibrium temperature and the expansion within the solidification sequence appear to have a strong influence on the susceptibility to macro - and micro - shrinkage in ductile iron castings. Green sand moulds, as less rigid moulds, encourage the formation of contraction defects, not only because of high initial expansion values, but also because of a higher cooling rate during solidification, and consequently, increased undercooling below the metastable equilibrium temperature up to the end of solidification.

  18. Metamagnetism, sign reversal and low temperature magnetocaloric effect in single-crystalline EuV2Al20

    NASA Astrophysics Data System (ADS)

    Ramesh Kumar, K.; Nair, Harikrishnan S.; Bhattacharyya, A.; Thamizhavel, A.; Strydom, André M.

    2018-04-01

    The Frank-Kasper cage compound EuV2Al20 crystallizes in the cubic structure with Fd 3 ‾ m space group and exhibits unusual magnetic and transport properties. The system undergoes an antiferromagnetic transition below 5.6 K wherein the Eu2+ moments are aligned anti-parallel along 〈1 1 1〉 direction and the system exhibits a weak metamagetic transition at the field of 1 T. Arrott plots (M2 vs H / M) show a "S" shaped variation in the low fields below TN and the plausible reason for the occurrence of negative slope is discussed. Isothermal magnetic entropy change is estimated from both magnetization and heat capacity measurements invoking the Maxwell's thermodynamic relations. Temperature variation of ΔSm showed a weak negative minimum and a sign reversal at the field value of 1 T due to field induced metamagnetic transition. Universal master curve is constructed by rescaling the ΔSm vs T curves in the context of analysing the nature of the magnetic transition.

  19. Dielectric behavior and AC conductivity of Cr doped α-Mn2O3

    NASA Astrophysics Data System (ADS)

    Chandra, Mohit; Yadav, Satish; Singh, K.

    2018-05-01

    The complex dielectric behavior of polycrystalline α-Mn2-xCrxO3 (x = 0.10) has been investigated isothermally at wide frequency range (4Hz-1 MHz) at different temperatures (300-390K). The dielectric spectroscopy results have been discussed in different formulism like dielectric constant, impedance and ac conductivity. The frequency dependent dielectric loss (tanδ) exhibit a clear relaxation behavior in the studied temperature range. The relaxation frequency increases with increasing temperature. These results are fitted using Arrhenius equation which suggest thermally activated process and the activation energy is 0.173±0.0024 eV. The normalized tanδ curves at different temperatures merge as a single master curve which indicate that the relaxation process follow the similar relaxation dynamics in the studied temperature range. Further, the dielectric relaxation follows non-Debye behavior. The impedance results inference that the grain boundary contribution dominate at lower frequency whereas grain contribution appeared at higher frequencies and exhibit strong temperature dependence. The ac conductivity data shows that the ac conductivity increases with increasing temperature which corroborate the semiconducting nature of the studied sample.

  20. Universal scaling and nonlinearity of aggregate price impact in financial markets.

    PubMed

    Patzelt, Felix; Bouchaud, Jean-Philippe

    2018-01-01

    How and why stock prices move is a centuries-old question still not answered conclusively. More recently, attention shifted to higher frequencies, where trades are processed piecewise across different time scales. Here we reveal that price impact has a universal nonlinear shape for trades aggregated on any intraday scale. Its shape varies little across instruments, but drastically different master curves are obtained for order-volume and -sign impact. The scaling is largely determined by the relevant Hurst exponents. We further show that extreme order-flow imbalance is not associated with large returns. To the contrary, it is observed when the price is pinned to a particular level. Prices move only when there is sufficient balance in the local order flow. In fact, the probability that a trade changes the midprice falls to zero with increasing (absolute) order-sign bias along an arc-shaped curve for all intraday scales. Our findings challenge the widespread assumption of linear aggregate impact. They imply that market dynamics on all intraday time scales are shaped by correlations and bilateral adaptation in the flows of liquidity provision and taking.

  1. Universal scaling and nonlinearity of aggregate price impact in financial markets

    NASA Astrophysics Data System (ADS)

    Patzelt, Felix; Bouchaud, Jean-Philippe

    2018-01-01

    How and why stock prices move is a centuries-old question still not answered conclusively. More recently, attention shifted to higher frequencies, where trades are processed piecewise across different time scales. Here we reveal that price impact has a universal nonlinear shape for trades aggregated on any intraday scale. Its shape varies little across instruments, but drastically different master curves are obtained for order-volume and -sign impact. The scaling is largely determined by the relevant Hurst exponents. We further show that extreme order-flow imbalance is not associated with large returns. To the contrary, it is observed when the price is pinned to a particular level. Prices move only when there is sufficient balance in the local order flow. In fact, the probability that a trade changes the midprice falls to zero with increasing (absolute) order-sign bias along an arc-shaped curve for all intraday scales. Our findings challenge the widespread assumption of linear aggregate impact. They imply that market dynamics on all intraday time scales are shaped by correlations and bilateral adaptation in the flows of liquidity provision and taking.

  2. Nonlinear price impact from linear models

    NASA Astrophysics Data System (ADS)

    Patzelt, Felix; Bouchaud, Jean-Philippe

    2017-12-01

    The impact of trades on asset prices is a crucial aspect of market dynamics for academics, regulators, and practitioners alike. Recently, universal and highly nonlinear master curves were observed for price impacts aggregated on all intra-day scales (Patzelt and Bouchaud 2017 arXiv:1706.04163). Here we investigate how well these curves, their scaling, and the underlying return dynamics are captured by linear ‘propagator’ models. We find that the classification of trades as price-changing versus non-price-changing can explain the price impact nonlinearities and short-term return dynamics to a very high degree. The explanatory power provided by the change indicator in addition to the order sign history increases with increasing tick size. To obtain these results, several long-standing technical issues for model calibration and testing are addressed. We present new spectral estimators for two- and three-point cross-correlations, removing the need for previously used approximations. We also show when calibration is unbiased and how to accurately reveal previously overlooked biases. Therefore, our results contribute significantly to understanding both recent empirical results and the properties of a popular class of impact models.

  3. Mixed-mode fatigue fracture of adhesive joints in harsh environments and nonlinear viscoelastic modeling of the adhesive

    NASA Astrophysics Data System (ADS)

    Arzoumanidis, Alexis Gerasimos

    A four point bend, mixed-mode, reinforced, cracked lap shear specimen experimentally simulated adhesive joints between load bearing composite parts in automotive components. The experiments accounted for fatigue, solvent and temperature effects on a swirled glass fiber composite adherend/urethane adhesive system. Crack length measurements based on compliance facilitated determination of da/dN curves. A digital image processing technique was also utilized to monitor crack growth from in situ images of the side of the specimen. Linear elastic fracture mechanics and finite elements were used to determine energy release rate and mode-mix as a function of crack length for this specimen. Experiments were conducted in air and in a salt water bath at 10, 26 and 90°C. Joints tested in the solvent were fully saturated. In air, both increasing and decreasing temperature relative to 26°C accelerated crack growth rates. In salt water, crack growth rates increased with increasing temperature. Threshold energy release rate is shown to be the most appropriate design criteria for joints of this system. In addition, path of the crack is discussed and fracture surfaces are examined on three length scales. Three linear viscoelastic properties were measured for the neat urethane adhesive. Dynamic tensile compliance (D*) was found using a novel extensometer and results were considerably more accurate and precise than standard DMTA testing. Dynamic shear compliance (J*) was determined using an Arcan specimen. Dynamic Poisson's ratio (nu*) was extracted from strain gage data analyzed to include gage reinforcement. Experiments spanned three frequency decades and isothermal data was shifted by time-temperature superposition to create master curves spanning thirty decades. Master curves were fit to time domain Prony series. Shear compliance inferred from D* and nu* compared well with measured J*, forming a basis for finding the complete time dependent material property matrix for this isotropic material. A constitutive model is introduced which replaces time with internal energy in time-temperature superposition. Internal energy for mechanical loading was calculated from stress history and time domain Prony series representation of compliance. The model also included pressure and volume effects. Ramp loading experiments conducted at strain rates spanning three decades were effectively predicted, but unloading predictions were poor.

  4. Studies of learned helplessness in honey bees (Apis mellifera ligustica).

    PubMed

    Dinges, Christopher W; Varnon, Christopher A; Cota, Lisa D; Slykerman, Stephen; Abramson, Charles I

    2017-04-01

    The current study reports 2 experiments investigating learned helplessness in the honey bee (Apis mellifera ligustica). In Experiment 1, we used a traditional escape method but found the bees' activity levels too high to observe changes due to treatment conditions. The bees were not able to learn in this traditional escape procedure; thus, such procedures may be inappropriate to study learned helplessness in honey bees. In Experiment 2, we used an alternative punishment, or passive avoidance, method to investigate learned helplessness. Using a master and yoked design where bees were trained as either master or yoked and tested as either master or yoked, we found that prior training with unavoidable and inescapable shock in the yoked condition interfered with avoidance and escape behavior in the later master condition. Unlike control bees, learned helplessness bees failed to restrict their movement to the safe compartment following inescapable shock. Unlike learned helplessness studies in other animals, no decrease in general activity was observed. Furthermore, we did not observe a "freezing" response to inescapable aversive stimuli-a phenomenon, thus far, consistently observed in learned helplessness tests with other species. The bees, instead, continued to move back and forth between compartments despite punishment in the incorrect compartment. These findings suggest that, although traditional escape methods may not be suitable, honey bees display learned helplessness in passive avoidance procedures. Thus, regardless of behavioral differences from other species, honey bees can be a unique invertebrate model organism for the study of learned helplessness. (PsycINFO Database Record (c) 2017 APA, all rights reserved).

  5. On the reduction of occultation light curves. [stellar occultations by planets

    NASA Technical Reports Server (NTRS)

    Wasserman, L.; Veverka, J.

    1973-01-01

    The two basic methods of reducing occultation light curves - curve fitting and inversion - are reviewed and compared. It is shown that the curve fitting methods have severe problems of nonuniqueness. In addition, in the case of occultation curves dominated by spikes, it is not clear that such solutions are meaningful. The inversion method does not suffer from these drawbacks. Methods of deriving temperature profiles from refractivity profiles are then examined. It is shown that, although the temperature profiles are sensitive to small errors in the refractivity profile, accurate temperatures can be obtained, particularly at the deeper levels of the atmosphere. The ambiguities that arise when the occultation curve straddles the turbopause are briefly discussed.

  6. [Haptic tracking control for minimally invasive robotic surgery].

    PubMed

    Xu, Zhaohong; Song, Chengli; Wu, Wenwu

    2012-06-01

    Haptic feedback plays a significant role in minimally invasive robotic surgery (MIRS). A major deficiency of the current MIRS is the lack of haptic perception for the surgeon, including the commercially available robot da Vinci surgical system. In this paper, a dynamics model of a haptic robot is established based on Newton-Euler method. Because it took some period of time in exact dynamics solution, we used a digital PID arithmetic dependent on robot dynamics to ensure real-time bilateral control, and it could improve tracking precision and real-time control efficiency. To prove the proposed method, an experimental system in which two Novint Falcon haptic devices acting as master-slave system has been developed. Simulations and experiments showed proposed methods could give instrument force feedbacks to operator, and bilateral control strategy is an effective method to master-slave MIRS. The proposed methods could be used to tele-robotic system.

  7. Evaluation of Statistical Methods for Modeling Historical Resource Production and Forecasting

    NASA Astrophysics Data System (ADS)

    Nanzad, Bolorchimeg

    This master's thesis project consists of two parts. Part I of the project compares modeling of historical resource production and forecasting of future production trends using the logit/probit transform advocated by Rutledge (2011) with conventional Hubbert curve fitting, using global coal production as a case study. The conventional Hubbert/Gaussian method fits a curve to historical production data whereas a logit/probit transform uses a linear fit to a subset of transformed production data. Within the errors and limitations inherent in this type of statistical modeling, these methods provide comparable results. That is, despite that apparent goodness-of-fit achievable using the Logit/Probit methodology, neither approach provides a significant advantage over the other in either explaining the observed data or in making future projections. For mature production regions, those that have already substantially passed peak production, results obtained by either method are closely comparable and reasonable, and estimates of ultimately recoverable resources obtained by either method are consistent with geologically estimated reserves. In contrast, for immature regions, estimates of ultimately recoverable resources generated by either of these alternative methods are unstable and thus, need to be used with caution. Although the logit/probit transform generates high quality-of-fit correspondence with historical production data, this approach provides no new information compared to conventional Gaussian or Hubbert-type models and may have the effect of masking the noise and/or instability in the data and the derived fits. In particular, production forecasts for immature or marginally mature production systems based on either method need to be regarded with considerable caution. Part II of the project investigates the utility of a novel alternative method for multicyclic Hubbert modeling tentatively termed "cycle-jumping" wherein overlap of multiple cycles is limited. The model is designed in a way that each cycle is described by the same three parameters as conventional multicyclic Hubbert model and every two cycles are connected with a transition width. Transition width indicates the shift from one cycle to the next and is described as weighted coaddition of neighboring two cycles. It is determined by three parameters: transition year, transition width, and gamma parameter for weighting. The cycle-jumping method provides superior model compared to the conventional multicyclic Hubbert model and reflects historical production behavior more reasonably and practically, by better modeling of the effects of technological transitions and socioeconomic factors that affect historical resource production behavior by explicitly considering the form of the transitions between production cycles.

  8. Chandra Source Catalog: User Interface

    NASA Astrophysics Data System (ADS)

    Bonaventura, Nina; Evans, Ian N.; Rots, Arnold H.; Tibbetts, Michael S.; van Stone, David W.; Zografou, Panagoula; Primini, Francis A.; Glotfelty, Kenny J.; Anderson, Craig S.; Chen, Judy C.; Davis, John E.; Doe, Stephen M.; Evans, Janet D.; Fabbiano, Giuseppina; Galle, Elizabeth C.; Gibbs, Danny G., II; Grier, John D.; Hain, Roger; Hall, Diane M.; Harbo, Peter N.; He, Helen; Houck, John C.; Karovska, Margarita; Kashyap, Vinay L.; Lauer, Jennifer; McCollough, Michael L.; McDowell, Jonathan C.; Miller, Joseph B.; Mitschang, Arik W.; Morgan, Douglas L.; Mossman, Amy E.; Nichols, Joy S.; Nowak, Michael A.; Plummer, David A.; Refsdal, Brian L.; Siemiginowska, Aneta L.; Sundheim, Beth A.; Winkelman, Sherry L.

    2009-09-01

    The Chandra Source Catalog (CSC) is intended to be the definitive catalog of all X-ray sources detected by Chandra. For each source, the CSC provides positions and multi-band fluxes, as well as derived spatial, spectral, and temporal source properties. Full-field and source region data products are also available, including images, photon event lists, light curves, and spectra. The Chandra X-ray Center CSC website (http://cxc.harvard.edu/csc/) is the place to visit for high-level descriptions of each source property and data product included in the catalog, along with other useful information, such as step-by-step catalog tutorials, answers to FAQs, and a thorough summary of the catalog statistical characterization. Eight categories of detailed catalog documents may be accessed from the navigation bar on most of the 50+ CSC pages; these categories are: About the Catalog, Creating the Catalog, Using the Catalog, Catalog Columns, Column Descriptions, Documents, Conferences, and Useful Links. There are also prominent links to CSCview, the CSC data access GUI, and related help documentation, as well as a tutorial for using the new CSC/Google Earth interface. Catalog source properties are presented in seven scientific categories, within two table views: the Master Source and Source Observations tables. Each X-ray source has one ``master source'' entry and one or more ``source observation'' entries, the details of which are documented on the CSC ``Catalog Columns'' pages. The master source properties represent the best estimates of the properties of a source; these are extensively described on the following pages of the website: Position and Position Errors, Source Flags, Source Extent and Errors, Source Fluxes, Source Significance, Spectral Properties, and Source Variability. The eight tutorials (``threads'') available on the website serve as a collective guide for accessing, understanding, and manipulating the source properties and data products provided by the catalog.

  9. An in vitro comparison of photogrammetric and conventional complete-arch implant impression techniques.

    PubMed

    Bergin, Junping Ma; Rubenstein, Jeffrey E; Mancl, Lloyd; Brudvik, James S; Raigrodski, Ariel J

    2013-10-01

    Conventional impression techniques for recording the location and orientation of implant-supported, complete-arch prostheses are time consuming and prone to error. The direct optical recording of the location and orientation of implants, without the need for intermediate transfer steps, could reduce or eliminate those disadvantages. The objective of this study was to assess the feasibility of using a photogrammetric technique to record the location and orientation of multiple implants and to compare the results with those of a conventional complete-arch impression technique. A stone cast of an edentulous mandibular arch containing 5 implant analogs was fabricated to create a master model. The 3-dimensional (3D) spatial orientations of implant analogs on the master model were measured with a coordinate measuring machine (CMM) (control). Five definitive casts were made from the master model with a splinted impression technique. The positions of the implant analogs on the 5 casts were measured with a NobelProcera scanner (conventional method). Prototype optical targets were attached to the master model implant analogs, and 5 sets of images were recorded with a digital camera and a standardized image capture protocol. Dimensional data were imported into commercially available photogrammetry software (photogrammetric method). The precision and accuracy of the 2 methods were compared with a 2-sample t test (α=.05) and a 95% confidence interval. The location precision (standard error of measurement) for CMM was 3.9 µm (95% CI 2.7 to 7.1), for photogrammetry, 5.6 µm (95% CI 3.4 to 16.1), and for the conventional method, 17.2 µm (95% CI 10.3 to 49.4). The average measurement error was 26.2 µm (95% CI 15.9 to 36.6) for the conventional method and 28.8 µm (95% CI 24.8 to 32.9) for the photogrammetric method. The overall measurement accuracy was not significantly different when comparing the conventional to the photogrammetric method (mean difference = -2.6 µm, 95% CI -12.8 to 7.6). The precision of the photogrammetric method was similar to CMM, but lower for the conventional method as compared to CMM and the photogrammetric method. However, the overall measurement accuracy of the photogrammetric and conventional methods was similar. Copyright © 2013 The Editorial Council of the Journal of Prosthetic Dentistry. Published by Mosby, Inc. All rights reserved.

  10. Preventing conflicts among bid curves used with transactive controllers in a market-based resource allocation system

    DOEpatents

    Fuller, Jason C.; Chassin, David P.; Pratt, Robert G.; Hauer, Matthew; Tuffner, Francis K.

    2017-03-07

    Disclosed herein are representative embodiments of methods, apparatus, and systems for distributing a resource (such as electricity) using a resource allocation system. One of the disclosed embodiments is a method for operating a transactive thermostatic controller configured to submit bids to a market-based resource allocation system. According to the exemplary method, a first bid curve is determined, the first bid curve indicating a first set of bid prices for corresponding temperatures and being associated with a cooling mode of operation for a heating and cooling system. A second bid curve is also determined, the second bid curve indicating a second set of bid prices for corresponding temperatures and being associated with a heating mode of operation for a heating and cooling system. In this embodiment, the first bid curve, the second bid curve, or both the first bid curve and the second bid curve are modified to prevent overlap of any portion of the first bid curve and the second bid curve.

  11. Diagnostic accuracy of MRI in the measurement of glenoid bone loss.

    PubMed

    Gyftopoulos, Soterios; Hasan, Saqib; Bencardino, Jenny; Mayo, Jason; Nayyar, Samir; Babb, James; Jazrawi, Laith

    2012-10-01

    The purpose of this study is to assess the accuracy of MRI quantification of glenoid bone loss and to compare the diagnostic accuracy of MRI to CT in the measurement of glenoid bone loss. MRI, CT, and 3D CT examinations of 18 cadaveric glenoids were obtained after the creation of defects along the anterior and anteroinferior glenoid. The defects were measured by three readers separately and blindly using the circle method. These measurements were compared with measurements made on digital photographic images of the cadaveric glenoids. Paired sample Student t tests were used to compare the imaging modalities. Concordance correlation coefficients were also calculated to measure interobserver agreement. Our data show that MRI could be used to accurately measure glenoid bone loss with a small margin of error (mean, 3.44%; range, 2.06-5.94%) in estimated percentage loss. MRI accuracy was similar to that of both CT and 3D CT for glenoid loss measurements in our study for the readers familiar with the circle method, with 1.3% as the maximum expected difference in accuracy of the percentage bone loss between the different modalities (95% confidence). Glenoid bone loss can be accurately measured on MRI using the circle method. The MRI quantification of glenoid bone loss compares favorably to measurements obtained using 3D CT and CT. The accuracy of the measurements correlates with the level of training, and a learning curve is expected before mastering this technique.

  12. Extensions to decision curve analysis, a novel method for evaluating diagnostic tests, prediction models and molecular markers.

    PubMed

    Vickers, Andrew J; Cronin, Angel M; Elkin, Elena B; Gonen, Mithat

    2008-11-26

    Decision curve analysis is a novel method for evaluating diagnostic tests, prediction models and molecular markers. It combines the mathematical simplicity of accuracy measures, such as sensitivity and specificity, with the clinical applicability of decision analytic approaches. Most critically, decision curve analysis can be applied directly to a data set, and does not require the sort of external data on costs, benefits and preferences typically required by traditional decision analytic techniques. In this paper we present several extensions to decision curve analysis including correction for overfit, confidence intervals, application to censored data (including competing risk) and calculation of decision curves directly from predicted probabilities. All of these extensions are based on straightforward methods that have previously been described in the literature for application to analogous statistical techniques. Simulation studies showed that repeated 10-fold crossvalidation provided the best method for correcting a decision curve for overfit. The method for applying decision curves to censored data had little bias and coverage was excellent; for competing risk, decision curves were appropriately affected by the incidence of the competing risk and the association between the competing risk and the predictor of interest. Calculation of decision curves directly from predicted probabilities led to a smoothing of the decision curve. Decision curve analysis can be easily extended to many of the applications common to performance measures for prediction models. Software to implement decision curve analysis is provided.

  13. Master and novice secondary science teachers' understandings and use of the learning cycle

    NASA Astrophysics Data System (ADS)

    Reap, Melanie Ann

    2000-09-01

    The learning cycle paradigm had been used in science classrooms for nearly four decades. This investigation seeks to reveal how the 1earning cycle, as originally designed, is currently understood and implemented by teachers in authentic classroom settings. The specific purposes of this study were: (1) to describe teachers who use the learning cycle and compare their understandings and perceptions of the learning cycle procedure in instruction; (2) to elicit novice and master teacher perspectives on their instruction and determine their perception of the process by which learning cycles are implemented in the science classroom; (3) to describe the context of science instruction in the novice and master teacher's classroom to ascertain how the teacher facilitates implementation of the learning cycle paradigm in their authentic classroom setting. The study used a learning cycle survey, interviews and classroom observations using the Learning Cycle Teacher Behavior Instruments and the Verbal Interaction Category System to explore these features of learning cycle instruction. The learning cycle survey was administered to a sample of teachers who use the learning cycle, including master and novice learning cycle teachers. One master and one novice learning cycle teacher were selected from this sample for further study. Analysis of the surveys showed no significant differences in master and novice teacher understandings of the learning cycle as assessed by the instrument. However, interviews and observations of the selected master and novice learning cycle teachers showed several differences in how the paradigm is understood and implemented in the classroom. The master learning cycle teacher showed a more developed teaching philosophy and had more engaged, extensive interactions with students. The novice learning cycle teacher held a more naive teaching philosophy and had fewer, less developed interactions with students. The most significant difference was seen in the use of questioning and discussion. The master teacher used diverse questioning techniques and guided students in discussion of their findings while the novice teachers used more rote response questions and controlled the discussion. The findings of this study have implications for science teacher education, especially in the preparation of teachers in science methods courses and student teaching, and in in-service education programs.

  14. Evaluation of white-to-white distance and anterior chamber depth measurements using the IOL Master, slit-lamp adapted optical coherence tomography and digital photographs in phakic eyes.

    PubMed

    Wilczyński, Michał; Pośpiech-Zabierek, Aleksandra

    2015-01-01

    The accurate measurement of the anterior chamber internal diameter and depth is important in ophthalmic diagnosis and before some eye surgery procedures. The purpose of the study was to compare the white-to-white distance measurements performed using the IOL-Master and photography with internal anterior chamber diameter determined using slit lamp adapted optical coherence tomography in healthy eyes, and to compare anterior chamber depth measurements by IOL-Master and slit lamp adapted optical coherence tomography. The data were gathered prospectively from a non-randomized consecutive series of patients. The examined group consisted of 46 eyes of 39 patients. White-to-white was measured using IOL-Master and photographs of the eye were taken with a digital camera. Internal anterior chamber diameter was measured with slit-lamp adapted optical coherence tomography. Anterior chamber depth was measured using the IOL Master and slit-lamp adapted optical coherence tomography. Statistical analysis was performed using parametric tests. A Bland-Altman plot was drawn. White-to-white distance by the IOL Master was 11.8 +/- 0.40 mm, on photographs it was 11.29 +/- 0.58 mm and internal anterior chamber diameter by slit-lamp adapted optical coherence tomography was 11.34?0.54 mm. A significant difference was found between IOL-Master and slit-lamp adapted optical coherence tomography (p<0.01), as well as between IOL Master and digital photographs (p<0.01). There was no difference between SL-OCT and digital photographs (p>0.05). All measurements were correlated (Spearman p<0.001). Mean anterior chamber depth determined using the IOL-Master was 2.99 +/- 0.50 mm and by slit-lamp adapted optical coherence tomography was 2.56 +/- 0.46 mm. The difference was statistically significant (p<0.001). The correlation between the values was also statistically significant (Spearman, p<0.001). Automated measurements using IOL-Master yield constantly higher values than measurements based on direct eye visualization slit-lamp adapted optical coherence tomography and digital photographs. In order to obtain accurate measurements of the internal anterior chamber diameter and anterior chamber depth, a method involving direct visualization of intraocular structures should be used.

  15. Multiple-methods investigation of recharge at a humid-region fractured rock site, Pennsylvania, USA

    USGS Publications Warehouse

    Heppner, C.S.; Nimmo, J.R.; Folmar, G.J.; Gburek, W.J.; Risser, D.W.

    2007-01-01

    Lysimeter-percolate and well-hydrograph analyses were combined to evaluate recharge for the Masser Recharge Site (central Pennsylvania, USA). In humid regions, aquifer recharge through an unconfined low-porosity fractured-rock aquifer can cause large magnitude water-table fluctuations over short time scales. The unsaturated hydraulic characteristics of the subsurface porous media control the magnitude and timing of these fluctuations. Data from multiple sets of lysimeters at the site show a highly seasonal pattern of percolate and exhibit variability due to both installation factors and hydraulic property heterogeneity. Individual event analysis of well hydrograph data reveals the primary influences on water-table response, namely rainfall depth, rainfall intensity, and initial water-table depth. Spatial and seasonal variability in well response is also evident. A new approach for calculating recharge from continuous water-table elevation records using a master recession curve (MRC) is demonstrated. The recharge estimated by the MRC approach when assuming a constant specific yield is seasonal to a lesser degree than the recharge estimate resulting from the lysimeter analysis. Partial reconciliation of the two recharge estimates is achieved by considering a conceptual model of flow processes in the highly-heterogeneous underlying fractured porous medium. ?? Springer-Verlag 2007.

  16. Characterizing granular networks using topological metrics

    NASA Astrophysics Data System (ADS)

    Dijksman, Joshua A.; Kovalcinova, Lenka; Ren, Jie; Behringer, Robert P.; Kramar, Miroslav; Mischaikow, Konstantin; Kondic, Lou

    2018-04-01

    We carry out a direct comparison of experimental and numerical realizations of the exact same granular system as it undergoes shear jamming. We adjust the numerical methods used to optimally represent the experimental settings and outcomes up to microscopic contact force dynamics. Measures presented here range from microscopic through mesoscopic to systemwide characteristics of the system. Topological properties of the mesoscopic force networks provide a key link between microscales and macroscales. We report two main findings: (1) The number of particles in the packing that have at least two contacts is a good predictor for the mechanical state of the system, regardless of strain history and packing density. All measures explored in both experiments and numerics, including stress-tensor-derived measures and contact numbers depend in a universal manner on the fraction of nonrattler particles, fNR. (2) The force network topology also tends to show this universality, yet the shape of the master curve depends much more on the details of the numerical simulations. In particular we show that adding force noise to the numerical data set can significantly alter the topological features in the data. We conclude that both fNR and topological metrics are useful measures to consider when quantifying the state of a granular system.

  17. Comparison of two methods to determine fan performance curves using computational fluid dynamics

    NASA Astrophysics Data System (ADS)

    Onma, Patinya; Chantrasmi, Tonkid

    2018-01-01

    This work investigates a systematic numerical approach that employs Computational Fluid Dynamics (CFD) to obtain performance curves of a backward-curved centrifugal fan. Generating the performance curves requires a number of three-dimensional simulations with varying system loads at a fixed rotational speed. Two methods were used and their results compared to experimental data. The first method incrementally changes the mass flow late through the inlet boundary condition while the second method utilizes a series of meshes representing the physical damper blade at various angles. The generated performance curves from both methods are compared with an experiment setup in accordance with the AMCA fan performance testing standard.

  18. A curved surface micro-moiré method and its application in evaluating curved surface residual stress

    NASA Astrophysics Data System (ADS)

    Zhang, Hongye; Wu, Chenlong; Liu, Zhanwei; Xie, Huimin

    2014-09-01

    The moiré method is typically applied to the measurement of deformations of a flat surface while, for a curved surface, this method is rarely used other than for projection moiré or moiré interferometry. Here, a novel colour charge-coupled device (CCD) micro-moiré method has been developed, based on which a curved surface micro-moiré (CSMM) method is proposed with a colour CCD and optical microscope (OM). In the CSMM method, no additional reference grating is needed as a Bayer colour filter array (CFA) installed on the OM in front of the colour CCD image sensor performs this role. Micro-moiré fringes with high contrast are directly observed with the OM through the Bayer CFA under the special condition of observing a curved specimen grating. The principle of the CSMM method based on a colour CCD micro-moiré method and its application range and error analysis are all described in detail. In an experiment, the curved surface residual stress near a welded seam on a stainless steel tube was investigated using the CSMM method.

  19. Rehabilitation reliability of the road pavement structure with recycled base course with foamed bitumen

    NASA Astrophysics Data System (ADS)

    Buczyński, P.

    2018-05-01

    This article presents a new approach to reliability assessment of the road structure in which the base layer will be constructed in the process of cold deep recycling with foamed bitumen. In order to properly assess the reliability of the structure with the recycled base, it is necessary to determine the distribution of stress and strain in typical pavement layer systems. The true stress and strain values were established for particular structural layers using the complex modulus (E*) determined based on the master curves. The complex modulus was determined by the direct tension-compression test on cylindrical specimens (DTC-CY) at five temperatures (-7°C, 5°C, 13°C, 25°C, 40°C) and six loading times (0.1 Hz, 0.3 Hz, 1 Hz, 3 Hz, 10 Hz, 20 Hz) in accordance with EN 12697-26 in the linear viscoelasticity (LVE) range for small strains ranging from 25 to 50 με. The master curves of the complex modulus were constructed using the Richards model for the mixtures typically incorporated in structural layers, i.e., SMA11, AC16W, AC22P and MCAS. The values of the modulus characterizing particular layers were determined with temperature distribution in the structure taken into account, when the surface temperature was 40°C. The stress distribution was established for those calculation models. The stress values were used to evaluate the fatigue life under controlled stress conditions (IT-FT). This evaluation, with the controlled stress corresponding to that in the structure, facilitated the quality assessment of the rehabilitated recycled base course. Results showed that the recycled base mixtures having the indirect tensile strength (ITSDRY) similar to the stress in the structure under analysis needed an additional fatigue life evaluation in the indirect tensile test ITT. This approach to the recycled base quality assessment will allow eliminating the damage induced by overloading.

  20. Modeling the rheological behavior of thermosonic extracted guava, pomelo, and soursop juice concentrates at different concentration and temperature using a new combination model

    PubMed Central

    Abdullah, Norazlin; Yusof, Yus A.; Talib, Rosnita A.

    2017-01-01

    Abstract This study has modeled the rheological behavior of thermosonic extracted pink‐fleshed guava, pink‐fleshed pomelo, and soursop juice concentrates at different concentrations and temperatures. The effects of concentration on consistency coefficient (K) and flow behavior index (n) of the fruit juice concentrates was modeled using a master curve which utilized the concentration‐temperature shifting to allow a general prediction of rheological behaviors covering a wide concentration. For modeling the effects of temperature on K and n, the integration of two functions from the Arrhenius and logistic sigmoidal growth equations has provided a new model which gave better description of the properties. It also alleviated the problems of negative region when using the Arrhenius model alone. The fitted regression using this new model has improved coefficient of determination, R 2 values above 0.9792 as compared to using the Arrhenius and logistic sigmoidal models alone, which presented minimum R 2 of 0.6243 and 0.9440, respectively. Practical applications In general, juice concentrate is a better form of food for transportation, preservation, and ingredient. Models are necessary to predict the effects of processing factors such as concentration and temperature on the rheological behavior of juice concentrates. The modeling approach allows prediction of behaviors and determination of processing parameters. The master curve model introduced in this study simplifies and generalized rheological behavior of juice concentrates over a wide range of concentration when temperature factor is insignificant. The proposed new mathematical model from the combination of the Arrhenius and logistic sigmoidal growth models has improved and extended description of rheological properties of fruit juice concentrates. It also solved problems of negative values of consistency coefficient and flow behavior index prediction using existing model, the Arrhenius equation. These rheological data modeling provide good information for the juice processing and equipment manufacturing needs. PMID:29479123

  1. The Assessment and Validation of Mini-Compact Tension Test Specimen Geometry and Progress in Establishing Technique for Fracture Toughness Master Curves for Reactor Pressure Vessel Steels

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Sokolov, Mikhail A.; Nanstad, Randy K.

    Small specimens are playing the key role in evaluating properties of irradiated materials. The use of small specimens provides several advantages. Typically, only a small volume of material can be irradiated in a reactor at desirable conditions in terms of temperature, neutron flux, and neutron dose. A small volume of irradiated material may also allow for easier handling of specimens. Smaller specimens reduce the amount of radioactive material, minimizing personnel exposures and waste disposal. However, use of small specimens imposes a variety of challenges as well. These challenges are associated with proper accounting for size effects and transferability of smallmore » specimen data to the real structures of interest. Any fracture toughness specimen that can be made out of the broken halves of standard Charpy specimens may have exceptional utility for evaluation of reactor pressure vessels (RPVs) since it would allow one to determine and monitor directly actual fracture toughness instead of requiring indirect predictions using correlations established with impact data. The Charpy V-notch specimen is the most commonly used specimen geometry in surveillance programs. Assessment and validation of mini-CT specimen geometry has been performed on previously well characterized HSST Plate 13B, an A533B class 1 steel. It was shown that the fracture toughness transition temperature measured by these Mini-CT specimens is within the range of To values that were derived from various large fracture toughness specimens. Moreover, the scatter of the fracture toughness values measured by Mini-CT specimens perfectly follows the Weibull distribution function providing additional proof for validation of this geometry for the Master Curve evaluation of rector pressure vessel steels. Moreover, the International collaborative program has been developed to extend the assessment and validation efforts to irradiated weld metal. The program is underway and involves ORNL, CRIEPI, and EPRI.« less

  2. A New Method of Preparing a Master Card from the "National Union Catalog"

    ERIC Educational Resources Information Center

    Schertz, Morris; Shavit, David

    1971-01-01

    The University of Denver is employing a new method for producing copy from the National Union Catalog" which has distinct advantages over other existing methods, particularly as far as cost per copy is concerned. (1 reference) (Author)

  3. Extraction and Analysis of Traditional Chinese Medicine Crops Based on Multitemporal High Resolution Data-Taking Qiaocheng District of Bozhou as AN Example

    NASA Astrophysics Data System (ADS)

    Yu, H.; He, J.; Zhou, H.; Guan, F.; Li, L.; Ren, B.; Wang, Z.

    2018-04-01

    Remote sensing technology has become an important method to rapidly acquireing of planting layout and composition of regional crops.It is very important to accurately master the planting area of Chinese medicine crops in the Characteristic planting area because it relations to accurately master the cultivation of Chinese medicine crops, formulate related policies and adjustment of crop planting structure.The author puts forward a method of using remote sencing technology for momitoring Chinese medicine which has good applicability and generalization. This paper took Qiaocheng District of Bozhou as an example to Verify the feasibility of the method, providing a reference for solving the problem of interpretation and extraction of Chinese medicinal materials in the region.

  4. Calculating work in weakly driven quantum master equations: Backward and forward equations

    NASA Astrophysics Data System (ADS)

    Liu, Fei

    2016-01-01

    I present a technical report indicating that the two methods used for calculating characteristic functions for the work distribution in weakly driven quantum master equations are equivalent. One involves applying the notion of quantum jump trajectory [Phys. Rev. E 89, 042122 (2014), 10.1103/PhysRevE.89.042122], while the other is based on two energy measurements on the combined system and reservoir [Silaev et al., Phys. Rev. E 90, 022103 (2014), 10.1103/PhysRevE.90.022103]. These represent backward and forward methods, respectively, which adopt a very similar approach to that of the Kolmogorov backward and forward equations used in classical stochastic theory. The microscopic basis for the former method is also clarified. In addition, a previously unnoticed equality related to the heat is also revealed.

  5. A self-adapting heuristic for automatically constructing terrain appreciation exercises

    NASA Astrophysics Data System (ADS)

    Nanda, S.; Lickteig, C. L.; Schaefer, P. S.

    2008-04-01

    Appreciating terrain is a key to success in both symmetric and asymmetric forms of warfare. Training to enable Soldiers to master this vital skill has traditionally required their translocation to a selected number of areas, each affording a desired set of topographical features, albeit with limited breadth of variety. As a result, the use of such methods has proved to be costly and time consuming. To counter this, new computer-aided training applications permit users to rapidly generate and complete training exercises in geo-specific open and urban environments rendered by high-fidelity image generation engines. The latter method is not only cost-efficient, but allows any given exercise and its conditions to be duplicated or systematically varied over time. However, even such computer-aided applications have shortcomings. One of the principal ones is that they usually require all training exercises to be painstakingly constructed by a subject matter expert. Furthermore, exercise difficulty is usually subjectively assessed and frequently ignored thereafter. As a result, such applications lack the ability to grow and adapt to the skill level and learning curve of each trainee. In this paper, we present a heuristic that automatically constructs exercises for identifying key terrain. Each exercise is created and administered in a unique iteration, with its level of difficulty tailored to the trainee's ability based on the correctness of that trainee's responses in prior iterations.

  6. The standard centrifuge method accurately measures vulnerability curves of long-vesselled olive stems.

    PubMed

    Hacke, Uwe G; Venturas, Martin D; MacKinnon, Evan D; Jacobsen, Anna L; Sperry, John S; Pratt, R Brandon

    2015-01-01

    The standard centrifuge method has been frequently used to measure vulnerability to xylem cavitation. This method has recently been questioned. It was hypothesized that open vessels lead to exponential vulnerability curves, which were thought to be indicative of measurement artifact. We tested this hypothesis in stems of olive (Olea europea) because its long vessels were recently claimed to produce a centrifuge artifact. We evaluated three predictions that followed from the open vessel artifact hypothesis: shorter stems, with more open vessels, would be more vulnerable than longer stems; standard centrifuge-based curves would be more vulnerable than dehydration-based curves; and open vessels would cause an exponential shape of centrifuge-based curves. Experimental evidence did not support these predictions. Centrifuge curves did not vary when the proportion of open vessels was altered. Centrifuge and dehydration curves were similar. At highly negative xylem pressure, centrifuge-based curves slightly overestimated vulnerability compared to the dehydration curve. This divergence was eliminated by centrifuging each stem only once. The standard centrifuge method produced accurate curves of samples containing open vessels, supporting the validity of this technique and confirming its utility in understanding plant hydraulics. Seven recommendations for avoiding artefacts and standardizing vulnerability curve methodology are provided. © 2014 The Authors. New Phytologist © 2014 New Phytologist Trust.

  7. System and method for time synchronization in a wireless network

    DOEpatents

    Gonia, Patrick S.; Kolavennu, Soumitri N.; Mahasenan, Arun V.; Budampati, Ramakrishna S.

    2010-03-30

    A system includes multiple wireless nodes forming a cluster in a wireless network, where each wireless node is configured to communicate and exchange data wirelessly based on a clock. One of the wireless nodes is configured to operate as a cluster master. Each of the other wireless nodes is configured to (i) receive time synchronization information from a parent node, (ii) adjust its clock based on the received time synchronization information, and (iii) broadcast time synchronization information based on the time synchronization information received by that wireless node. The time synchronization information received by each of the other wireless nodes is based on time synchronization information provided by the cluster master so that the other wireless nodes substantially synchronize their clocks with the clock of the cluster master.

  8. Fatigue behavior of a cross-ply metal matrix composite at elevated temperature under strain controlled mode. Master`s thesis

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Dennis, L.B.

    1994-12-01

    This research extends the existing knowledge of cross-ply metal matrix composites (MMC) to include fatigue behavior under strain-controlled fully reversed loading. This study investigated fatigue life, failure modes and damage mechanisms of the SCS-6/Ti-15-3, (O/9O)2s, MMC. The laminate was subjected to fully reversed fatigue at elevated temperature (427 deg C) at various strain levels. Stress, strain and modulus data were analyzed to characterize the macro-mechanical behavior of the composite. Microscopy and fractography were accomplished to identify and characterize the damage mechanisms at the microscopic level. Failure modes varied according to the maximum applied strain level showing either mixed mode (i.e.more » combination of both fiber and matrix dominated modes) or matrix dominated fatigue failures. As expected, higher strain loadings resulted in more ductility of the matrix at failure, evidenced by fracture surface features. For testing of the same composite laminate, the fatigue life under strain controlled mode slightly increased, compared to its load-controlled mode counterpart, using the effective strain range comparison basis. However, the respective fatigue life curves converged in the high cycle region, suggesting that the matrix dominated failure mode produces equivalent predicted fatigue lives for both control modes.« less

  9. A Comparison of Apical Transportation in Severely Curved Canals Induced by Reciproc and BioRaCe Systems

    PubMed Central

    Nabavizadeh, Mohammadreza; Abbaszadegan, Abbas; Khojastepour, Leila; Amirhosseini, Mohsen; Kiani, Ebrahim

    2014-01-01

    Introduction: Preserving the apical root structure during cleaning and shaping of the canal has always been a challenge in endodontics particularly when the root canals are curved. The purpose of this in vitro study was to compare the apical transportation induced by the Reciproc and BioRaCe rotary systems in preparing the mesiobuccal root canal of the human maxillary molars. Materials and Methods: The mesiobuccal canals of sixty extracted maxillary molars with curvature angle of 25˚-35˚ were selected and randomly assigned into two groups. Each canal was prepared by either Reciproc or BioRaCe rotary systems. A double-digital radiographic technique and AutoCAD software were used to compare the apical transportation at 0.5, 1, 2, 3, 4 and 5 mm distances from the working length (WL). The distance between the master apical rotary file and the initial K-file in the superimposed radiographs determined the amount of apical transportation. An independent t-test was used to compare the groups. The statistical significant level was set at 0.05. Results: Apical transportation of the Reciproc group was significantly greater than the BioRaCe group in all distances (P<0.001). The maximum apical transportation occurred in the Reciproc group at 0.5 mm from the WL (0.048±0.0028 mm) and the minimum occurred for BioRaCe at 5 mm from the WL (0.010±0.0005 mm). Conclusions: The Reciproc system produced significantly more apical transportation than the BioRaCe, but this fact does not seem to negatively alter the clinical success or quality of root canal treatment. PMID:24688580

  10. Time reducing exposure containing 18 fluorine flourodeoxyglucose master vial dispensing in hot lab: Omega technique

    PubMed Central

    Rao, Vatturi Venkata Satya Prabhakar; Manthri, Ranadheer; Hemalatha, Pottumuthu; Kumar, Vuyyuru Navin; Azhar, Mohammad

    2016-01-01

    Hot lab dispensing of large doses of 18 fluorine fluorodeoxyglucose in master vials supplied from the cyclotrons requires high degrees of skill to handle high doses. Presently practiced conventional method of fractionating from the inverted tiltable vial pig mounted on a metal frame has its own limitations such as increasing isotope handling times and exposure to the technologist. Innovative technique devised markedly improves the fractionating efficiency along with speed, precision, and reduced dose exposure. PMID:27095872

  11. Bilateral force reflection for teleoperators with masters and slaves with dissimilar and possibly redundant kinematics

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Jansen, J.F.; Babcock, S.M.

    1989-11-01

    Several bilateral control techniques and methods for exploiting redundant slaves are investigated as a part of research to develop and analyze bilateral, force-reflecting control methodologies for teleoperator systems with kinematic dissimilar masters and slaves. The study indicates that, with force/torque sensing at the wrist, and an impedance type of controller with the appropriate joint compensation, a significant improvement in performance and controllability of a teleoperator system can be achieved. 32 refs., 6 figs., 2 tabs.

  12. Integrating quantitative and qualitative evaluation methods to compare two teacher inservice training programs

    NASA Astrophysics Data System (ADS)

    Lawrenz, Frances; McCreath, Heather

    Qualitative and quantitative evaluation procedures were used to compare two physical-science teacher inservice training programs. The two programs followed the master teacher training model espoused by NSF but used different types of master teachers and types of activities. The two evaluation procedures produced different results and together they provided a much clearer picture of the strengths and weaknesses of the two programs. Using only one approach or the other would have substantially altered the conclusions.

  13. Maximizing Program Delivery in Extension: Lessons from Leadership for Transformation.

    ERIC Educational Resources Information Center

    Laughlin, Kevin M.; Schmidt, Janet L.

    1995-01-01

    Reviews advantages and disadvantages of four extension delivery methods: partnerships, master volunteer programs, information centers, and regional programs. Concluded that the key is matching individual, community, and emerging needs with the right method. (SK)

  14. Comparison of Kato-Katz thick-smear and McMaster egg counting method for the assessment of drug efficacy against soil-transmitted helminthiasis in school children in Jimma Town, Ethiopia.

    PubMed

    Bekana, Teshome; Mekonnen, Zeleke; Zeynudin, Ahmed; Ayana, Mio; Getachew, Mestawet; Vercruysse, Jozef; Levecke, Bruno

    2015-10-01

    There is a paucity of studies that compare efficacy of drugs obtained by different diagnostic methods. We compared the efficacy of a single oral dose albendazole (400 mg), measured as egg reduction rate, against soil-transmitted helminth infections in 210 school children (Jimma Town, Ethiopia) using both Kato-Katz thick smear and McMaster egg counting method. Our results indicate that differences in sensitivity and faecal egg counts did not imply a significant difference in egg reduction rate estimates. The choice of a diagnostic method to assess drug efficacy should not be based on sensitivity and faecal egg counts only. © The Author 2015. Published by Oxford University Press on behalf of Royal Society of Tropical Medicine and Hygiene. All rights reserved. For permissions, please e-mail: journals.permissions@oup.com.

  15. Master-Leader-Slave Cuckoo Search with Parameter Control for ANN Optimization and Its Real-World Application to Water Quality Prediction

    PubMed Central

    Jaddi, Najmeh Sadat; Abdullah, Salwani; Abdul Malek, Marlinda

    2017-01-01

    Artificial neural networks (ANNs) have been employed to solve a broad variety of tasks. The selection of an ANN model with appropriate weights is important in achieving accurate results. This paper presents an optimization strategy for ANN model selection based on the cuckoo search (CS) algorithm, which is rooted in the obligate brood parasitic actions of some cuckoo species. In order to enhance the convergence ability of basic CS, some modifications are proposed. The fraction Pa of the n nests replaced by new nests is a fixed parameter in basic CS. As the selection of Pa is a challenging issue and has a direct effect on exploration and therefore on convergence ability, in this work the Pa is set to a maximum value at initialization to achieve more exploration in early iterations and it is decreased during the search to achieve more exploitation in later iterations until it reaches the minimum value in the final iteration. In addition, a novel master-leader-slave multi-population strategy is used where the slaves employ the best fitness function among all slaves, which is selected by the leader under a certain condition. This fitness function is used for subsequent Lévy flights. In each iteration a copy of the best solution of each slave is migrated to the master and then the best solution is found by the master. The method is tested on benchmark classification and time series prediction problems and the statistical analysis proves the ability of the method. This method is also applied to a real-world water quality prediction problem with promising results. PMID:28125609

  16. Master-Leader-Slave Cuckoo Search with Parameter Control for ANN Optimization and Its Real-World Application to Water Quality Prediction.

    PubMed

    Jaddi, Najmeh Sadat; Abdullah, Salwani; Abdul Malek, Marlinda

    2017-01-01

    Artificial neural networks (ANNs) have been employed to solve a broad variety of tasks. The selection of an ANN model with appropriate weights is important in achieving accurate results. This paper presents an optimization strategy for ANN model selection based on the cuckoo search (CS) algorithm, which is rooted in the obligate brood parasitic actions of some cuckoo species. In order to enhance the convergence ability of basic CS, some modifications are proposed. The fraction Pa of the n nests replaced by new nests is a fixed parameter in basic CS. As the selection of Pa is a challenging issue and has a direct effect on exploration and therefore on convergence ability, in this work the Pa is set to a maximum value at initialization to achieve more exploration in early iterations and it is decreased during the search to achieve more exploitation in later iterations until it reaches the minimum value in the final iteration. In addition, a novel master-leader-slave multi-population strategy is used where the slaves employ the best fitness function among all slaves, which is selected by the leader under a certain condition. This fitness function is used for subsequent Lévy flights. In each iteration a copy of the best solution of each slave is migrated to the master and then the best solution is found by the master. The method is tested on benchmark classification and time series prediction problems and the statistical analysis proves the ability of the method. This method is also applied to a real-world water quality prediction problem with promising results.

  17. Nonstationary stochastic charge fluctuations of a dust particle in plasmas.

    PubMed

    Shotorban, B

    2011-06-01

    Stochastic charge fluctuations of a dust particle that are due to discreteness of electrons and ions in plasmas can be described by a one-step process master equation [T. Matsoukas and M. Russell, J. Appl. Phys. 77, 4285 (1995)] with no exact solution. In the present work, using the system size expansion method of Van Kampen along with the linear noise approximation, a Fokker-Planck equation with an exact Gaussian solution is developed by expanding the master equation. The Gaussian solution has time-dependent mean and variance governed by two ordinary differential equations modeling the nonstationary process of dust particle charging. The model is tested via the comparison of its results to the results obtained by solving the master equation numerically. The electron and ion currents are calculated through the orbital motion limited theory. At various times of the nonstationary process of charging, the model results are in a very good agreement with the master equation results. The deviation is more significant when the standard deviation of the charge is comparable to the mean charge in magnitude.

  18. [A way of helping "Mr. Minotaur" and "Ms. Ariadne" to exit from the multiple morbidity labyrinth: the "master problems"].

    PubMed

    Turabián, J L; Pérez Franco, B

    2016-01-01

    Multiple morbidity seems to be "infinite" and so is not easy to make useful decisions. A new concept is introduced: the "master problems", as a qualitative method to facilitate the exit from this maze of multiple morbidity. Metaphors from the art world have been used to teach this concept. These "master problems" generally remain hidden and can only "unravel" between the interstices of multiple morbidity, when the details of the system that defines the problem are explained. A problem with "energy" or a "master problem" is complex, multiple and dramatic or theatrical--everything in the clinical history history make us look into that particular question. It is what gives us a blow to the stomach, which causes our hearts to beat faster, that moves us on many levels, which has a high "density of emotions", human elements, social symbols, and opens solutions in a patient. Copyright © 2015 Sociedad Española de Médicos de Atención Primaria (SEMERGEN). Publicado por Elsevier España, S.L.U. All rights reserved.

  19. Repurposing compact discs as master molds to fabricate high-performance organic nanowire field-effect transistors

    NASA Astrophysics Data System (ADS)

    Kim, Kyunghun; Cho, Jinhwi; Jhon, Heesauk; Jeon, Jongwook; Kang, Myounggon; Eon Park, Chan; Lee, Jihoon; An, Tae Kyu

    2017-05-01

    Organic field-effect transistors (OFETs) have been developed over the past few decades due to their potential applications in future electronics such as wearable and foldable electronics. As the electrical performance of OFETs has improved, patterning organic semiconducting crystals has become a key issue for their commercialization. However, conventional soft lithographic techniques have required the use of expensive processes to fabricate high-resolution master molds. In this study, we demonstrated a cost-effective method to prepare nanopatterned master molds for the fabrication of high-performance nanowire OFETs. We repurposed commercially available compact discs (CDs) as master molds because they already have linear nanopatterns on their surface. Flexible nanopatterned templates were replicated from the CDs using UV-imprint lithography. Subsequently, 6,13-bis-(triisopropylsilylethynyl) pentacene nanowires (NWs) were grown from the templates using a capillary force-assisted lithographic technique. The NW-based OFETs showed a high average field-effect mobility of 2.04 cm2 V-1 s-1. This result was attributed to the high crystallinity of the NWs and to their crystal orientation favorable for charge transport.

  20. Attitudes toward Master's and Clinical Doctorate Degrees in Physical Therapy

    PubMed Central

    Mistry, Yamini; Francis, Christian; Haldane, Jessica; Symonds, Scott; Uguccioni, Erika; Berg, Katherine

    2014-01-01

    ABSTRACT Purpose: To examine the attitudes of a self-selected sample of Canadian physical therapists toward the transition from bachelor's to master's degrees and the implementation of clinical doctorate degrees in physical therapy (PT). Methods: A cross-sectional survey was conducted using a modified Dillman tailored approach. All eligible members of the Canadian Physiotherapy Association (CPA) were invited to participate. Results: Of 1,397 Canadian physical therapists who responded to the survey, 45% favoured the transition from bachelor's to master's degrees, 21% did not, and 34% were neutral; 27% favoured a transition from a master's to a doctoral degree for entry into practice in PT, 53% did not favour this transition, and 20% were neutral. Finally, 56% favoured the implementation of a post-professional clinical doctorate (PPCD) in PT, 23% did not, and 21% were neutral. Conclusions: Overall, a self-selected sample of Canadian physical therapists supported the future implementation of a post-professional clinical doctorate degree in PT but did not support an entry-to-practice doctoral degree. However, these results must be interpreted with caution because of the study's small sample size. PMID:25922561

  1. An Accurate Co-registration Method for Airborne Repeat-pass InSAR

    NASA Astrophysics Data System (ADS)

    Dong, X. T.; Zhao, Y. H.; Yue, X. J.; Han, C. M.

    2017-10-01

    Interferometric Synthetic Aperture Radar (InSAR) technology plays a significant role in topographic mapping and surface deformation detection. Comparing with spaceborne repeat-pass InSAR, airborne repeat-pass InSAR solves the problems of long revisit time and low-resolution images. Due to the advantages of flexible, accurate, and fast obtaining abundant information, airborne repeat-pass InSAR is significant in deformation monitoring of shallow ground. In order to getting precise ground elevation information and interferometric coherence of deformation monitoring from master and slave images, accurate co-registration must be promised. Because of side looking, repeat observing path and long baseline, there are very different initial slant ranges and flight heights between repeat flight paths. The differences of initial slant ranges and flight height lead to the pixels, located identical coordinates on master and slave images, correspond to different size of ground resolution cells. The mismatching phenomenon performs very obvious on the long slant range parts of master image and slave image. In order to resolving the different sizes of pixels and getting accurate co-registration results, a new method is proposed based on Range-Doppler (RD) imaging model. VV-Polarization C-band airborne repeat-pass InSAR images were used in experiment. The experiment result shows that the proposed method leads to superior co-registration accuracy.

  2. Capturing method for integral three-dimensional imaging using multiviewpoint robotic cameras

    NASA Astrophysics Data System (ADS)

    Ikeya, Kensuke; Arai, Jun; Mishina, Tomoyuki; Yamaguchi, Masahiro

    2018-03-01

    Integral three-dimensional (3-D) technology for next-generation 3-D television must be able to capture dynamic moving subjects with pan, tilt, and zoom camerawork as good as in current TV program production. We propose a capturing method for integral 3-D imaging using multiviewpoint robotic cameras. The cameras are controlled through a cooperative synchronous system composed of a master camera controlled by a camera operator and other reference cameras that are utilized for 3-D reconstruction. When the operator captures a subject using the master camera, the region reproduced by the integral 3-D display is regulated in real space according to the subject's position and view angle of the master camera. Using the cooperative control function, the reference cameras can capture images at the narrowest view angle that does not lose any part of the object region, thereby maximizing the resolution of the image. 3-D models are reconstructed by estimating the depth from complementary multiviewpoint images captured by robotic cameras arranged in a two-dimensional array. The model is converted into elemental images to generate the integral 3-D images. In experiments, we reconstructed integral 3-D images of karate players and confirmed that the proposed method satisfied the above requirements.

  3. Automatic ICD-10 multi-class classification of cause of death from plaintext autopsy reports through expert-driven feature selection

    PubMed Central

    Mujtaba, Ghulam; Shuib, Liyana; Raj, Ram Gopal; Rajandram, Retnagowri; Shaikh, Khairunisa; Al-Garadi, Mohammed Ali

    2017-01-01

    Objectives Widespread implementation of electronic databases has improved the accessibility of plaintext clinical information for supplementary use. Numerous machine learning techniques, such as supervised machine learning approaches or ontology-based approaches, have been employed to obtain useful information from plaintext clinical data. This study proposes an automatic multi-class classification system to predict accident-related causes of death from plaintext autopsy reports through expert-driven feature selection with supervised automatic text classification decision models. Methods Accident-related autopsy reports were obtained from one of the largest hospital in Kuala Lumpur. These reports belong to nine different accident-related causes of death. Master feature vector was prepared by extracting features from the collected autopsy reports by using unigram with lexical categorization. This master feature vector was used to detect cause of death [according to internal classification of disease version 10 (ICD-10) classification system] through five automated feature selection schemes, proposed expert-driven approach, five subset sizes of features, and five machine learning classifiers. Model performance was evaluated using precisionM, recallM, F-measureM, accuracy, and area under ROC curve. Four baselines were used to compare the results with the proposed system. Results Random forest and J48 decision models parameterized using expert-driven feature selection yielded the highest evaluation measure approaching (85% to 90%) for most metrics by using a feature subset size of 30. The proposed system also showed approximately 14% to 16% improvement in the overall accuracy compared with the existing techniques and four baselines. Conclusion The proposed system is feasible and practical to use for automatic classification of ICD-10-related cause of death from autopsy reports. The proposed system assists pathologists to accurately and rapidly determine underlying cause of death based on autopsy findings. Furthermore, the proposed expert-driven feature selection approach and the findings are generally applicable to other kinds of plaintext clinical reports. PMID:28166263

  4. Linking Parameters Estimated with the Generalized Graded Unfolding Model: A Comparison of the Accuracy of Characteristic Curve Methods

    ERIC Educational Resources Information Center

    Anderson Koenig, Judith; Roberts, James S.

    2007-01-01

    Methods for linking item response theory (IRT) parameters are developed for attitude questionnaire responses calibrated with the generalized graded unfolding model (GGUM). One class of IRT linking methods derives the linking coefficients by comparing characteristic curves, and three of these methods---test characteristic curve (TCC), item…

  5. Friction and universal contact area law for randomly rough viscoelastic contacts.

    PubMed

    Scaraggi, M; Persson, B N J

    2015-03-18

    We present accurate numerical results for the friction force and the contact area for a viscoelastic solid (rubber) in sliding contact with hard, randomly rough substrates. The rough surfaces are self-affine fractal with roughness over several decades in length scales. We calculate the contribution to the friction from the pulsating deformations induced by the substrate asperities. We also calculate how the area of real contact, A(v, p), depends on the sliding speed v and on the nominal contact pressure p, and we show how the contact area for any sliding speed can be obtained from a universal master curve A(p). The numerical results are found to be in good agreement with the predictions of an analytical contact mechanics theory.

  6. Desmin filaments studied by quasi-elastic light scattering.

    PubMed Central

    Hohenadl, M; Storz, T; Kirpal, H; Kroy, K; Merkel, R

    1999-01-01

    We studied polymers of desmin, a muscle-specific type III intermediate filament protein, using quasi-elastic light scattering. Desmin was purified from chicken gizzard. Polymerization was induced either by 2 mM MgCl(2) or 150 mM NaCl. The polymer solutions were in the semidilute regime. We concluded that the persistence length of the filaments is between 0.1 and 1 microm. In all cases, we found a hydrodynamic diameter of desmin filaments of 16-18 nm. The filament dynamics exhibits a characteristic frequency in the sense that correlation functions measured on one sample but at different scattering vectors collapse onto a single master curve when time is normalized by the experimentally determined initial decay rate. PMID:10512839

  7. Beyond Kickboards & Pull Buoys.

    ERIC Educational Resources Information Center

    Armstrong, Charles W.; Imwold, Charles H.

    1983-01-01

    Swimming teachers must analyze their students' strokes for errors and provide constructive feedback. To do this requires mastering complex movement analysis techniques and feedback methods. An aquatics instructional methods course at Florida State University made use of strategies to develop these competencies. (PP)

  8. 48 CFR 217.7102 - General.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 217.7102 Federal Acquisition Regulations System DEFENSE ACQUISITION REGULATIONS SYSTEM, DEPARTMENT OF DEFENSE CONTRACTING METHODS AND CONTRACT TYPES SPECIAL CONTRACTING METHODS Master Agreement for Repair and... contractors located outside the United States and its outlying areas. (c) Activities may issue job orders...

  9. 48 CFR 217.7102 - General.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... 217.7102 Federal Acquisition Regulations System DEFENSE ACQUISITION REGULATIONS SYSTEM, DEPARTMENT OF DEFENSE CONTRACTING METHODS AND CONTRACT TYPES SPECIAL CONTRACTING METHODS Master Agreement for Repair and... contractors located outside the United States and its outlying areas. (c) Activities may issue job orders...

  10. 48 CFR 217.7102 - General.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... 217.7102 Federal Acquisition Regulations System DEFENSE ACQUISITION REGULATIONS SYSTEM, DEPARTMENT OF DEFENSE CONTRACTING METHODS AND CONTRACT TYPES SPECIAL CONTRACTING METHODS Master Agreement for Repair and... contractors located outside the United States and its outlying areas. (c) Activities may issue job orders...

  11. 48 CFR 217.7102 - General.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 217.7102 Federal Acquisition Regulations System DEFENSE ACQUISITION REGULATIONS SYSTEM, DEPARTMENT OF DEFENSE CONTRACTING METHODS AND CONTRACT TYPES SPECIAL CONTRACTING METHODS Master Agreement for Repair and... contractors located outside the United States and its outlying areas. (c) Activities may issue job orders...

  12. 48 CFR 217.7102 - General.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... 217.7102 Federal Acquisition Regulations System DEFENSE ACQUISITION REGULATIONS SYSTEM, DEPARTMENT OF DEFENSE CONTRACTING METHODS AND CONTRACT TYPES SPECIAL CONTRACTING METHODS Master Agreement for Repair and... contractors located outside the United States and its outlying areas. (c) Activities may issue job orders...

  13. Double degree master program: Optical Design

    NASA Astrophysics Data System (ADS)

    Bakholdin, Alexey; Kujawinska, Malgorzata; Livshits, Irina; Styk, Adam; Voznesenskaya, Anna; Ezhova, Kseniia; Ermolayeva, Elena; Ivanova, Tatiana; Romanova, Galina; Tolstoba, Nadezhda

    2015-10-01

    Modern tendencies of higher education require development of master programs providing achievement of learning outcomes corresponding to quickly variable job market needs. ITMO University represented by Applied and Computer Optics Department and Optical Design and Testing Laboratory jointly with Warsaw University of Technology represented by the Institute of Micromechanics and Photonics at The Faculty of Mechatronics have developed a novel international master double-degree program "Optical Design" accumulating the expertise of both universities including experienced teaching staff, educational technologies, and experimental resources. The program presents studies targeting research and professional activities in high-tech fields connected with optical and optoelectronics devices, optical engineering, numerical methods and computer technologies. This master program deals with the design of optical systems of various types, assemblies and layouts using computer modeling means; investigation of light distribution phenomena; image modeling and formation; development of optical methods for image analysis and optical metrology including optical testing, materials characterization, NDT and industrial control and monitoring. The goal of this program is training a graduate capable to solve a wide range of research and engineering tasks in optical design and metrology leading to modern manufacturing and innovation. Variability of the program structure provides its flexibility and adoption according to current job market demands and personal learning paths for each student. In addition considerable proportion of internship and research expands practical skills. Some special features of the "Optical Design" program which implements the best practices of both Universities, the challenges and lessons learnt during its realization are presented in the paper.

  14. The Delphi Method for Graduate Research

    ERIC Educational Resources Information Center

    Skulmoski, Gregory J.; Hartman, Francis T.; Krahn, Jennifer

    2007-01-01

    The Delphi method is an attractive method for graduate students completing masters and PhD level research. It is a flexible research technique that has been successfully used in our program at the University of Calgary to explore new concepts within and outside of the information systems body of knowledge. The Delphi method is an iterative process…

  15. QMRPF-UKF Master-Slave Filtering for the Attitude Determination of Micro-Nano Satellites Using Gyro and Magnetometer

    PubMed Central

    Cui, Peiling; Zhang, Huijuan

    2010-01-01

    In this paper, the problem of estimating the attitude of a micro-nano satellite, obtaining geomagnetic field measurements via a three-axis magnetometer and obtaining angle rate via gyro, is considered. For this application, a QMRPF-UKF master-slave filtering method is proposed, which uses the QMRPF and UKF algorithms to estimate the rotation quaternion and the gyro bias parameters, respectively. The computational complexicity related to the particle filtering technique is eliminated by introducing a multiresolution approach that permits a significant reduction in the number of particles. This renders QMRPF-UKF master-slave filter computationally efficient and enables its implementation with a remarkably small number of particles. Simulation results by using QMRPF-UKF are given, which demonstrate the validity of the QMRPF-UKF nonlinear filter. PMID:22163448

  16. Electrochemical deposition onto self-assembled monolayers: new insights into micro- and nanofabrication.

    PubMed

    Schilardi, Patricia L; Dip, Patricio; dos Santos Claro, Paula C; Benítez, Guillermo A; Fonticelli, Mariano H; Azzaroni, Omar; Salvarezza, Roberto C

    2005-12-16

    Pattern transfer with high resolution is a frontier topic in the emerging field of nanotechnologies. Electrochemical molding is a possible route for nanopatterning metal, alloys and oxide surfaces with high resolution in a simple and inexpensive way. This method involves electrodeposition onto a conducting master covered by a self-assembled alkanethiolate monolayer (SAMs). This molecular film enables direct surface-relief pattern transfer from the conducting master to the inner face of the electrodeposit, and also allows an easy release of the electrodeposited film due their excellent anti-adherent properties. Replicas of the original conductive master can be also obtained by a simple two-step procedure. SAM quality and stability under electrodeposition conditions combined with the formation of smooth electrodeposits are crucial to obtain high-quality pattern transfer with sub-50 nm resolution.

  17. Increasing transcultural awareness: the McMaster-Aga Khan-CIDA Project workshop model.

    PubMed

    Smith, S E

    1997-01-01

    McMaster-Aga Khan-CIDA Project personnel at McMaster University School of Nursing over a period of four years designed and conducted eight one-day introductory workshops for nurses, faculty, staff, host families, and others involved with Pakistani nurses and Lady Health Visitors studying in Canada. The workshops (entitled Increasing Intercultural Awareness) assisted the Canadian and international participants to improve their awareness and knowledge of transcultural communication in preparation for working and socializing together. Using a participatory and active-learning approach, the workshop method introduced participants to transcultural communication; emphasized appreciation of cultural values, similarities and differences; and provided country-specific information on Pakistan. This article outlines the workshop design and rationale and describes specific examples of the transcultural nursing principles, practices, and teaching activities included in the one-day event.

  18. Solving the master equation without kinetic Monte Carlo: Tensor train approximations for a CO oxidation model

    NASA Astrophysics Data System (ADS)

    Gelß, Patrick; Matera, Sebastian; Schütte, Christof

    2016-06-01

    In multiscale modeling of heterogeneous catalytic processes, one crucial point is the solution of a Markovian master equation describing the stochastic reaction kinetics. Usually, this is too high-dimensional to be solved with standard numerical techniques and one has to rely on sampling approaches based on the kinetic Monte Carlo method. In this study we break the curse of dimensionality for the direct solution of the Markovian master equation by exploiting the Tensor Train Format for this purpose. The performance of the approach is demonstrated on a first principles based, reduced model for the CO oxidation on the RuO2(110) surface. We investigate the complexity for increasing system size and for various reaction conditions. The advantage over the stochastic simulation approach is illustrated by a problem with increased stiffness.

  19. Telerobotic control of a dextrous manipulator using master and six-DOF hand-controllers for space assembly and servicing tasks

    NASA Technical Reports Server (NTRS)

    O'Hara, John M.

    1987-01-01

    Two studies were conducted evaluating methods of controlling a telerobot; bilateral force reflecting master controllers and proportional rate six degrees of freedom (DOF) hand controllers. The first study compared the controllers on performance of single manipulator arm tasks, a peg-in-the-hole task, and simulated satellite orbital replacement unit changeout. The second study, a Space Station truss assembly task, required simultaneous operation of both manipulator arms (all 12 DOFs) and complex multiaxis slave arm movements. Task times were significantly longer and fewer errors were committed with the hand controllers. The hand controllers were also rated significantly higher in cognitive and manual control workload on the two-arm task. The master controllers were rated significantly higher in physical workload. There were no significant differences in ratings of manipulator control quality.

  20. A comparative scanning electron microscopic study of the effect of three different rotary instruments on smear layer formation.

    PubMed

    Shahi, Shahriar; Yavari, Hamid R; Rahimi, Saeed; Reyhani, Mohammad F; Kamarroosta, Zahra; Abdolrahimi, Majid

    2009-03-01

    The aim of this study was to evaluate the effect of RaCe, FlexMaster and ProFile rotary instruments on smear layer formation by scanning electron microscopy. Eighty-four caries-free freshly extracted human single-rooted teeth were selected and divided into three groups, each containing 28 teeth. The teeth were instrumented with rotary instruments sequentially: Group A: ProFile Rotary Instruments; Group B: FlexMaster Rotary Instruments; and Group C: RaCe Rotary Instruments. Instrumentation was performed by the crown-down method and according to the manufacturer's instructions. The specimens were then examined with SEM according to Hülsmann's classification. One-way ANOVA and a post hoc Tukey test were used for statistical analysis. The results showed that there were no statistically significant differences among the three groups in the coronal third (P = 0.39), but at the apical and middle thirds there were statistically significant differences between the RaCe group and the other groups (P < 0.05). Smear layer in the RaCe group was less than that in the ProFile and FlexMaster groups, but the difference between the ProFile group and FlexMaster group was not statistically significant (P > 0.05). It was concluded that RaCe Rotary Instruments produce less smear layer than FlexMaster and ProFile Rotary Instruments.

  1. Education in Care and Technology; Development and Evaluation of a First Cohort of an International Master Course.

    PubMed

    Willems, Charles G

    2017-01-01

    A report written as a personal communication based on the experience gathered by developing and delivery of a international professional master course. The organization of the curriculum consists of 16 modules. Using a framework of the user centered design and development cycle students receive domain knowledge related to user-orientation, business, innovation and implementation. Also, introduction is given to tools that can be used to investigate certain aspects. The course will be completed by the performance of master thesis research related of a practice oriented problem relevant to the work environment of the student. This master-course has been followed by a first cohort of 8 students. In this report, an evaluation is given on this first delivery. Organization of this course is complicated by the marketing conditions that have to be used. Students and teachers are well supported by the distance based learning environment. The 16 modules representing the content of the course contains a variety of subjects and methods and represents a huge educational load to the students. Translating this content to the development of the own applied research subject contributes to the learning process. The first cohort of students will complete their master thesis in July 2017. Further introduction of new cohorts will mainly depend on the possibility to reduce the financial constraints to participation.

  2. Comparison of fecal egg counting methods in four livestock species.

    PubMed

    Paras, Kelsey L; George, Melissa M; Vidyashankar, Anand N; Kaplan, Ray M

    2018-06-15

    Gastrointestinal nematode parasites are important pathogens of all domesticated livestock species. Fecal egg counts (FEC) are routinely used for evaluating anthelmintic efficacy and for making targeted anthelmintic treatment decisions. Numerous FEC techniques exist and vary in precision and accuracy. These performance characteristics are especially important when performing fecal egg count reduction tests (FECRT). The objective of this study was to compare the accuracy and precision of three commonly used FEC methods and determine if differences existed among livestock species. In this study, we evaluated the modified-Wisconsin, 3-chamber (high-sensitivity) McMaster, and Mini-FLOTAC methods in cattle, sheep, horses, and llamas in three phases. In the first phase, we performed an egg-spiking study to assess the egg recovery rate and accuracy of the different FEC methods. In the second phase, we examined clinical samples from four different livestock species and completed multiple replicate FEC using each method. In the last phase, we assessed the cheesecloth straining step as a potential source of egg loss. In the egg-spiking study, the Mini-FLOTAC recovered 70.9% of the eggs, which was significantly higher than either the McMaster (P = 0.002) or Wisconsin (P = 0.002). In the clinical samples from ruminants, Mini-FLOTAC consistently yielded the highest EPG, revealing a significantly higher level of egg recovery (P < 0.0001). For horses and llamas, both McMaster and Mini-FLOTAC yielded significantly higher EPG than Wisconsin (P < 0.0001, P < 0.0001, P < 0.001, and P = 0.024). Mini-FLOTAC was the most accurate method and was the most precise test for both species of ruminants. The Wisconsin method was the most precise for horses and McMaster was more precise for llama samples. We compared the Wisconsin and Mini-FLOTAC methods using a modified technique where both methods were performed using either the Mini-FLOTAC sieve or cheesecloth. The differences in the estimated mean EPG on log scale between the Wisconsin and mini-FLOTAC methods when cheesecloth was used (P < 0.0001) and when cheesecloth was excluded (P < 0.0001) were significant, providing strong evidence that the straining step is an important source of error. The high accuracy and precision demonstrated in this study for the Mini-FLOTAC, suggest that this method can be recommended for routine use in all host species. The benefits of Mini-FLOTAC will be especially relevant when high accuracy is important, such as when performing FECRT. Copyright © 2018 Elsevier B.V. All rights reserved.

  3. Personalized System of Instruction (Keller Method) for Medical School Biochemistry

    ERIC Educational Resources Information Center

    Weisman, Robert A.; Shapiro, David M.

    1973-01-01

    The Keller Method requires abolishing lectures as a vehicle of information transfer in favor of a study guide and breaking the biochemistry course into a number of units each to be mastered at the student's own pace. (Editor)

  4. 48 CFR 217.7104 - Contract clauses.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... Section 217.7104 Federal Acquisition Regulations System DEFENSE ACQUISITION REGULATIONS SYSTEM, DEPARTMENT OF DEFENSE CONTRACTING METHODS AND CONTRACT TYPES SPECIAL CONTRACTING METHODS Master Agreement for...) 252.217-7004, Job Orders and Compensation. (3) 252.217-7005, Inspection and Manner of Doing Work. (4...

  5. 48 CFR 217.7104 - Contract clauses.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... Section 217.7104 Federal Acquisition Regulations System DEFENSE ACQUISITION REGULATIONS SYSTEM, DEPARTMENT OF DEFENSE CONTRACTING METHODS AND CONTRACT TYPES SPECIAL CONTRACTING METHODS Master Agreement for...) 252.217-7004, Job Orders and Compensation. (3) 252.217-7005, Inspection and Manner of Doing Work. (4...

  6. 48 CFR 217.7104 - Contract clauses.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... Section 217.7104 Federal Acquisition Regulations System DEFENSE ACQUISITION REGULATIONS SYSTEM, DEPARTMENT OF DEFENSE CONTRACTING METHODS AND CONTRACT TYPES SPECIAL CONTRACTING METHODS Master Agreement for...) 252.217-7004, Job Orders and Compensation. (3) 252.217-7005, Inspection and Manner of Doing Work. (4...

  7. 48 CFR 217.7104 - Contract clauses.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... Section 217.7104 Federal Acquisition Regulations System DEFENSE ACQUISITION REGULATIONS SYSTEM, DEPARTMENT OF DEFENSE CONTRACTING METHODS AND CONTRACT TYPES SPECIAL CONTRACTING METHODS Master Agreement for...) 252.217-7004, Job Orders and Compensation. (3) 252.217-7005, Inspection and Manner of Doing Work. (4...

  8. Multimodal determination of Rayleigh dispersion and attenuation curves using the circle fit method

    NASA Astrophysics Data System (ADS)

    Verachtert, R.; Lombaert, G.; Degrande, G.

    2018-03-01

    This paper introduces the circle fit method for the determination of multi-modal Rayleigh dispersion and attenuation curves as part of a Multichannel Analysis of Surface Waves (MASW) experiment. The wave field is transformed to the frequency-wavenumber (fk) domain using a discretized Hankel transform. In a Nyquist plot of the fk-spectrum, displaying the imaginary part against the real part, the Rayleigh wave modes correspond to circles. The experimental Rayleigh dispersion and attenuation curves are derived from the angular sweep of the central angle of these circles. The method can also be applied to the analytical fk-spectrum of the Green's function of a layered half-space in order to compute dispersion and attenuation curves, as an alternative to solving an eigenvalue problem. A MASW experiment is subsequently simulated for a site with a regular velocity profile and a site with a soft layer trapped between two stiffer layers. The performance of the circle fit method to determine the dispersion and attenuation curves is compared with the peak picking method and the half-power bandwidth method. The circle fit method is found to be the most accurate and robust method for the determination of the dispersion curves. When determining attenuation curves, the circle fit method and half-power bandwidth method are accurate if the mode exhibits a sharp peak in the fk-spectrum. Furthermore, simulated and theoretical attenuation curves determined with the circle fit method agree very well. A similar correspondence is not obtained when using the half-power bandwidth method. Finally, the circle fit method is applied to measurement data obtained for a MASW experiment at a site in Heverlee, Belgium. In order to validate the soil profile obtained from the inversion procedure, force-velocity transfer functions were computed and found in good correspondence with the experimental transfer functions, especially in the frequency range between 5 and 80 Hz.

  9. Estimating the R-curve from residual strength data

    NASA Technical Reports Server (NTRS)

    Orange, T. W.

    1985-01-01

    A method is presented for estimating the crack-extension resistance curve (R-curve) from residual-strength (maximum load against original crack length) data for precracked fracture specimens. The method allows additional information to be inferred from simple test results, and that information can be used to estimate the failure loads of more complicated structures of the same material and thickness. The fundamentals of the R-curve concept are reviewed first. Then the analytical basis for the estimation method is presented. The estimation method has been verified in two ways. Data from the literature (involving several materials and different types of specimens) are used to show that the estimated R-curve is in good agreement with the measured R-curve. A recent predictive blind round-robin program offers a more crucial test. When the actual failure loads are disclosed, the predictions are found to be in good agreement.

  10. Incremental checking of Master Data Management model based on contextual graphs

    NASA Astrophysics Data System (ADS)

    Lamolle, Myriam; Menet, Ludovic; Le Duc, Chan

    2015-10-01

    The validation of models is a crucial step in distributed heterogeneous systems. In this paper, an incremental validation method is proposed in the scope of a Model Driven Engineering (MDE) approach, which is used to develop a Master Data Management (MDM) field represented by XML Schema models. The MDE approach presented in this paper is based on the definition of an abstraction layer using UML class diagrams. The validation method aims to minimise the model errors and to optimisethe process of model checking. Therefore, the notion of validation contexts is introduced allowing the verification of data model views. Description logics specify constraints that the models have to check. An experimentation of the approach is presented through an application developed in ArgoUML IDE.

  11. Memory Effects and Nonequilibrium Correlations in the Dynamics of Open Quantum Systems

    NASA Astrophysics Data System (ADS)

    Morozov, V. G.

    2018-01-01

    We propose a systematic approach to the dynamics of open quantum systems in the framework of Zubarev's nonequilibrium statistical operator method. The approach is based on the relation between ensemble means of the Hubbard operators and the matrix elements of the reduced statistical operator of an open quantum system. This key relation allows deriving master equations for open systems following a scheme conceptually identical to the scheme used to derive kinetic equations for distribution functions. The advantage of the proposed formalism is that some relevant dynamical correlations between an open system and its environment can be taken into account. To illustrate the method, we derive a non-Markovian master equation containing the contribution of nonequilibrium correlations associated with energy conservation.

  12. Inverse Diffusion Curves Using Shape Optimization.

    PubMed

    Zhao, Shuang; Durand, Fredo; Zheng, Changxi

    2018-07-01

    The inverse diffusion curve problem focuses on automatic creation of diffusion curve images that resemble user provided color fields. This problem is challenging since the 1D curves have a nonlinear and global impact on resulting color fields via a partial differential equation (PDE). We introduce a new approach complementary to previous methods by optimizing curve geometry. In particular, we propose a novel iterative algorithm based on the theory of shape derivatives. The resulting diffusion curves are clean and well-shaped, and the final image closely approximates the input. Our method provides a user-controlled parameter to regularize curve complexity, and generalizes to handle input color fields represented in a variety of formats.

  13. Motor unit number estimates and neuromuscular transmission in the tibialis anterior of master athletes: evidence that athletic older people are not spared from age-related motor unit remodeling.

    PubMed

    Piasecki, Mathew; Ireland, Alex; Coulson, Jessica; Stashuk, Dan W; Hamilton-Wright, Andrew; Swiecicka, Agnieszka; Rutter, Martin K; McPhee, Jamie S; Jones, David A

    2016-10-01

    Muscle motor unit numbers decrease markedly in old age, while remaining motor units are enlarged and can have reduced neuromuscular junction transmission stability. However, it is possible that regular intense physical activity throughout life can attenuate this remodeling. The aim of this study was to compare the number, size, and neuromuscular junction transmission stability of tibialis anterior (TA) motor units in healthy young and older men with those of exceptionally active master runners. The distribution of motor unit potential (MUP) size was determined from intramuscular electromyographic signals recorded in healthy male Young (mean ± SD, 26 ± 5 years), Old (71 ± 4 years) and Master Athletes (69 ± 3 years). Relative differences between groups in numbers of motor units was assessed using two methods, one comparing MUP size and muscle cross-sectional area (CSA) determined with MRI, the other comparing surface recorded MUPs with maximal compound muscle action potentials and commonly known as a "motor unit number estimate (MUNE)". Near fiber (NF) jiggle was measured to assess neuromuscular junction transmission stability. TA CSA did not differ between groups. MUNE values for the Old and Master Athletes were 45% and 40%, respectively, of the Young. Intramuscular MUPs of Old and Master Athletes were 43% and 56% larger than Young. NF jiggle was slightly higher in the Master Athletes, with no difference between Young and Old. These results show substantial and similar motor unit loss and remodeling in Master Athletes and Old individuals compared with Young, which suggests that lifelong training does not attenuate the age-related loss of motor units. © 2016 The Authors. Physiological Reports published by Wiley Periodicals, Inc. on behalf of the American Physiological Society and The Physiological Society.

  14. Structural conceptualization of learning experiences in nursing master's degree programs utilized in occupational health nursing activities.

    PubMed

    Aoyama, Wakako; Tatsumi, Asami

    2017-01-31

    In this study, concepts were constructed that express learning experiences in nursing master's degree programs utilized in occupational health nursing activities with the aim of clarifying those characteristics. This was based on the idea that elucidation of the characteristics of learning experiences in nursing master's degree programs used in occupational health nursing activities would be meaningful in providing high-quality occupational health services that respond to the needs of society. Semi-structured interviews were conducted with 10 people who fulfilled the three conditions of having completed a master's degree programs, working as an occupational health nurse after completion of the program, and not continuing on to a doctoral program. The nursing conceptualization method of Naomi Funashima was used. From the obtained data, 512 code items expressing learning experiences in master's degree programs utilized in occupational health nursing activities were identified. These items included five core categories (concepts), 34 categories, and 69 subcategories. The five concepts constructed were "Pursuit of expertise and self-evaluation," "Mutual understanding of various people that leads to human resources utilization," "Theoretical and academic learning that influences changes in activities," "Research learning that lead to activities based on scientific evidence," and "Learning that leads to high-quality activities making use of expertise." It was found that various learning experiences in the master's program to pursue the specialty of occupational health nurses in order to recognize their roles as well as the experiences to take the initiative in learning had been integrated in their activities after completion of the course and had contributed to their high-quality occupational health nursing activities. It was suggested that the learning experiences in the master's program, which had been revealed in this study, were the experiences necessary for providing high-quality occupational health nursing activities to satisfy the social needs.

  15. Material Analysis and Identification

    NASA Technical Reports Server (NTRS)

    2004-01-01

    KeyMaster Technologies, Inc., develops and markets specialized, hand-held X-ray fluorescence (XRF) instruments and unique tagging technology used to identify and authenticate materials or processes. NASA first met with this Kennewick, Washington-based company as the Agency began seeking companies to develop a hand-held instrument that would detect data matrix symbols on parts covered by paint and other coatings. Since the Federal Aviation Administration was also searching for methods to detect and eliminate the use of unapproved parts, it recommended that NASA and KeyMaster work together to develop a technology that would benefit both agencies.

  16. Generating a desired state for master's degree programs in science education through grounded theory research

    NASA Astrophysics Data System (ADS)

    Spector, Barbara S.

    This is the report of a two-year study using qualitative research methods to assess the training needs of science teachers in southern Florida. The respondents included individuals and groups comprising the educational enterprise and those outside the enterprise with the ability to influence policy in science education and implementation of that policy in Florida. The study resulted in recommendations describing the desired state for graduate training leading to a master's degree in science education and has implications for noncredit inservice activities.

  17. (abstract) Precision Time and Frequency Transfer Utilizing SONET OC-3

    NASA Technical Reports Server (NTRS)

    Stein, Sam; Calhoun, Malcom; Kuhnle, Paul; Sydnor, Richard; Gifford, Al

    1996-01-01

    An innovative method of distributing precise time and reference frequency to users located several kilometers from a frequency standard and master clock has been developed by the Timing Solutions Corporation of Boulder, CO. The Optical Two-Way Time Transfer System (OTWTTS) utilizes a commercial SONET OC-3 facility interface to physically connect a master unit to multiple slave units at remote locations. Optical fiber is a viable alternative to standard copper cable and microwave transmission. This paper discusses measurements of frequency and timing stability over the OTWTTS.

  18. Developments in holographic-based scanner designs

    NASA Astrophysics Data System (ADS)

    Rowe, David M.

    1997-07-01

    Holographic-based scanning systems have been used for years in the high resolution prepress markets where monochromatic lasers are generally utilized. However, until recently, due to the dispersive properties of holographic optical elements (HOEs), along with the high cost associated with recording 'master' HOEs, holographic scanners have not been able to penetrate major scanning markets such as the laser printer and digital copier markets, low to mid-range imagesetter markets, and the non-contact inspection scanner market. Each of these markets has developed cost effective laser diode based solutions using conventional scanning approaches such as polygon/f-theta lens combinations. In order to penetrate these markets, holographic-based systems must exhibit low cost and immunity to wavelength shifts associated with laser diodes. This paper describes recent developments in the design of holographic scanners in which multiple HOEs, each possessing optical power, are used in conjunction with one curved mirror to passively correct focal plane position errors and spot size changes caused by the wavelength instability of laser diodes. This paper also describes recent advancements in low cost production of high quality HOEs and curved mirrors. Together these developments allow holographic scanners to be economically competitive alternatives to conventional devices in every segment of the laser scanning industry.

  19. Guidelines for application of learning/cost improvement curves

    NASA Technical Reports Server (NTRS)

    Delionback, L. M.

    1975-01-01

    The differences between the terms learning curve and improvement curve are noted, as well as the differences between the Wright system and the Crawford system. Learning curve computational techniques were reviewed along with a method to arrive at a composite learning curve for a system given detail curves either by the functional techniques classification or simply categorized by subsystem. Techniques are discussed for determination of the theoretical first unit (TFU) cost using several of the currently accepted methods. Sometimes TFU cost is referred to as simply number one cost. A tabular presentation of the various learning curve slope values is given. A discussion of the various trends in the application of learning/improvement curves and an outlook for the future are presented.

  20. Seamless contiguity method for parallel segmentation of remote sensing image

    NASA Astrophysics Data System (ADS)

    Wang, Geng; Wang, Guanghui; Yu, Mei; Cui, Chengling

    2015-12-01

    Seamless contiguity is the key technology for parallel segmentation of remote sensing data with large quantities. It can be effectively integrate fragments of the parallel processing into reasonable results for subsequent processes. There are numerous methods reported in the literature for seamless contiguity, such as establishing buffer, area boundary merging and data sewing. et. We proposed a new method which was also based on building buffers. The seamless contiguity processes we adopt are based on the principle: ensuring the accuracy of the boundary, ensuring the correctness of topology. Firstly, block number is computed based on data processing ability, unlike establishing buffer on both sides of block line, buffer is established just on the right side and underside of the line. Each block of data is segmented respectively and then gets the segmentation objects and their label value. Secondly, choose one block(called master block) and do stitching on the adjacent blocks(called slave block), process the rest of the block in sequence. Through the above processing, topological relationship and boundaries of master block are guaranteed. Thirdly, if the master block polygons boundaries intersect with buffer boundary and the slave blocks polygons boundaries intersect with block line, we adopt certain rules to merge and trade-offs them. Fourthly, check the topology and boundary in the buffer area. Finally, a set of experiments were conducted and prove the feasibility of this method. This novel seamless contiguity algorithm provides an applicable and practical solution for efficient segmentation of massive remote sensing image.

  1. Accuracy of impression scanning compared with stone casts of implant impressions.

    PubMed

    Matta, Ragai Edward; Adler, Werner; Wichmann, Manfred; Heckmann, Siegfried Martin

    2017-04-01

    Accurate virtual implant models are a necessity for the fabrication of precisely fitting superstructures. The purpose of this in vitro study was to evaluate different methods with which to build an accurate virtual model of a 3-dimensional implant in the oral cavity; this model would then be used for iterative computer-aided design and computer-aided manufacturing (CAD-CAM) procedures. A titanium master model with 3 rigidly connected implants was manufactured and digitized with a noncontact industrial scanner to obtain a virtual master model. Impressions of the master model with the implant position locators (IPL) were made using vinyl siloxanether material. The impressions were scanned (Impression scanning technique group). For the transfer technique and pick-up technique groups (each group n=20), implant analogs were inserted into the impression copings, impressions were made using polyether, and casts were poured in Type 4 gypsum. The IPLs were screwed into the analogs and scanned. To compare the virtual master model with each virtual test model, a CAD interactive software, ATOS professional, was applied. The Kruskal-Wallis test was subsequently used to determine the overall difference between groups, with the Mann-Whitney U test used for pairwise comparisons. Through Bonferroni correction, the α-level was set to .017. The outcome revealed a significant difference among the 3 groups (P<.01) in terms of accuracy. With regard to total deviation, for all axes, the transfer technique generated the greatest divergence, 0.078 mm (±0.022), compared with the master model. Deviation with the pick-up technique was 0.041 mm (±0.009), with impression scanning generating the most accurate models with a deviation of 0.022 mm (±0.007). The impression scanning method improved the precision of CAD-CAM-fabricated superstructures. Copyright © 2016 Editorial Council for the Journal of Prosthetic Dentistry. Published by Elsevier Inc. All rights reserved.

  2. Expression of Master Regulators of T-cell, Helper T-cell and Follicular Helper T-cell Differentiation in Angioimmunoblastic T-cell Lymphoma.

    PubMed

    Matsumoto, Yosuke; Nagoshi, Hisao; Yoshida, Mihoko; Kato, Seiichi; Kuroda, Junya; Shimura, Kazuho; Kaneko, Hiroto; Horiike, Shigeo; Nakamura, Shigeo; Taniwaki, Masafumi

    2017-11-01

    Objective It has been postulated that the normal counterpart of angioimmunoblastic T-cell lymphoma (AITL) is the follicular helper T-cell (TFH). Recent immunological studies have identified several transcription factors responsible for T-cell differentiation. The master regulators associated with T-cell, helper T-cell (Th), and TFH differentiation are reportedly BCL11B, Th-POK, and BCL6, respectively. We explored the postulated normal counterpart of AITL with respect to the expression of the master regulators of T-cell differentiation. Methods We performed an immunohistochemical analysis in 15 AITL patients to determine the expression of the master regulators and several surface markers associated with T-cell differentiation. Results BCL11B was detected in 10 patients (67%), and the surface marker of T-cells (CD3) was detected in all patients. Only 2 patients (13%) expressed the marker of naïve T-cells (CD45RA), but all patients expressed the marker of effector T-cells (CD45RO). Nine patients expressed Th-POK (60%), and 7 (47%) expressed a set of surface antigens of Th (CD4-positive and CD8-negative). In addition, BCL6 and the surface markers of TFH (CXCL13, PD-1, and SAP) were detected in 11 (73%), 8 (53%), 14 (93%), and all patients, respectively. Th-POK-positive/BCL6-negative patients showed a significantly shorter overall survival (OS) than the other patients (median OS: 33.0 months vs. 74.0 months, p=0.020; log-rank test). Conclusion Many of the AITL patients analyzed in this study expressed the master regulators of T-cell differentiation. The clarification of the diagnostic significance and pathophysiology based on the expression of these master regulators in AITL is expected in the future.

  3. Development of an improved method for determining advisory speeds on horizontal curves.

    DOT National Transportation Integrated Search

    2016-07-01

    Horizontal curves are an integral part of the highway alignment. However, a disproportionately high number of severe : crashes occur on them. One method transportation agencies use to reduce the number crashes at horizontal curves is the : installati...

  4. [Teaching nursing research at bachelor and second level degree: opinions of nursing associate professors and nursing researchers].

    PubMed

    D'Aliesio, Lorella; Vellone, Ercole; Rega, Maria Luisa; Galletti, Caterina

    2006-01-01

    Nursing research is a systematic and very important enquiry for improving clients' quality of life and effective and efficient nursing care. National and international literature state that all nurses should have knowledge and responsibilities in research which are different in relation to their educational level. The aim of the present study was to collect opinions of the new professors in nursing about objectives, contents and methods for teaching nursing research at Bachelor and Master Degree. The sample was made of nine participants who were interviewed by twenty questions sent by e-mail. The interviews were analysed using quantitative-descriptive and qualitative-phenomenological methods (triangulation). Interviews revealed that Bachelor students should be educated to retrieve and criticise scientific literature, to apply research finding in practice and to collaborate in research studies; Master students should improve knowledge of Bachelor degree and be able to design and conduct research studies. Participants emphasised the importance of using active methodologies for teaching and to involve students in research. By analysing the literature and the results of the present study educational objectives for teaching nursing research at Bachelor and Master degree are defined.

  5. Method for encryption and transmission of digital keying data

    DOEpatents

    Mniszewski, Susan M.; Springer, Edward A.; Brenner, David P.

    1988-01-01

    A method for the encryption, transmission, and subsequent decryption of digital keying data. The method utilizes the Data Encryption Standard and is implemented by means of a pair of apparatus, each of which is selectable to operate as either a master unit or remote unit. Each unit contains a set of key encryption keys which are indexed by a common indexing system. The master unit operates upon command from the remote unit to generate a data encryption key and encrypt the data encryption key using a preselected key encryption key. The encrypted data encryption key and an index designator are then downloaded to the remote unit, where the data encryption key is decrypted for subsequent use in the encryption and transmission data. Downloading of the encrypted data encryption key enables frequent change of keys without requiring manual entry or storage of keys at the remote unit.

  6. From stochastic processes to numerical methods: A new scheme for solving reaction subdiffusion fractional partial differential equations

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Angstmann, C.N.; Donnelly, I.C.; Henry, B.I., E-mail: B.Henry@unsw.edu.au

    We have introduced a new explicit numerical method, based on a discrete stochastic process, for solving a class of fractional partial differential equations that model reaction subdiffusion. The scheme is derived from the master equations for the evolution of the probability density of a sum of discrete time random walks. We show that the diffusion limit of the master equations recovers the fractional partial differential equation of interest. This limiting procedure guarantees the consistency of the numerical scheme. The positivity of the solution and stability results are simply obtained, provided that the underlying process is well posed. We also showmore » that the method can be applied to standard reaction–diffusion equations. This work highlights the broader applicability of using discrete stochastic processes to provide numerical schemes for partial differential equations, including fractional partial differential equations.« less

  7. Solving the master equation without kinetic Monte Carlo: Tensor train approximations for a CO oxidation model

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Gelß, Patrick, E-mail: p.gelss@fu-berlin.de; Matera, Sebastian, E-mail: matera@math.fu-berlin.de; Schütte, Christof, E-mail: schuette@mi.fu-berlin.de

    2016-06-01

    In multiscale modeling of heterogeneous catalytic processes, one crucial point is the solution of a Markovian master equation describing the stochastic reaction kinetics. Usually, this is too high-dimensional to be solved with standard numerical techniques and one has to rely on sampling approaches based on the kinetic Monte Carlo method. In this study we break the curse of dimensionality for the direct solution of the Markovian master equation by exploiting the Tensor Train Format for this purpose. The performance of the approach is demonstrated on a first principles based, reduced model for the CO oxidation on the RuO{sub 2}(110) surface.more » We investigate the complexity for increasing system size and for various reaction conditions. The advantage over the stochastic simulation approach is illustrated by a problem with increased stiffness.« less

  8. The daily events and emotions of master's-level family therapy trainees in off-campus practicum settings.

    PubMed

    Edwards, Todd M; Patterson, Jo Ellen

    2012-10-01

    The Day Reconstruction Method (DRM) was used to assess the daily events and emotions of one program's master's-level family therapy trainees in off-campus practicum settings. This study examines the DRM reports of 35 family therapy trainees in the second year of their master's program in marriage and family therapy. Four themes emerged from the results: (i) Personal contact with peers-in-training engenders the most positive emotions during practicum; (ii) Trainees experience more positive emotions during therapy with families and couples in comparison with therapy with individuals; (iii) Positive affect increases over the course of a student's practicum year; and (iv) Trainees experience less positive affect in individual supervision in comparison with most other training activities. Flow theory offers guidance for supervisors helping trainees face developmental challenges of clinical training. © 2012 American Association for Marriage and Family Therapy.

  9. GPS/DR Error Estimation for Autonomous Vehicle Localization.

    PubMed

    Lee, Byung-Hyun; Song, Jong-Hwa; Im, Jun-Hyuck; Im, Sung-Hyuck; Heo, Moon-Beom; Jee, Gyu-In

    2015-08-21

    Autonomous vehicles require highly reliable navigation capabilities. For example, a lane-following method cannot be applied in an intersection without lanes, and since typical lane detection is performed using a straight-line model, errors can occur when the lateral distance is estimated in curved sections due to a model mismatch. Therefore, this paper proposes a localization method that uses GPS/DR error estimation based on a lane detection method with curved lane models, stop line detection, and curve matching in order to improve the performance during waypoint following procedures. The advantage of using the proposed method is that position information can be provided for autonomous driving through intersections, in sections with sharp curves, and in curved sections following a straight section. The proposed method was applied in autonomous vehicles at an experimental site to evaluate its performance, and the results indicate that the positioning achieved accuracy at the sub-meter level.

  10. GPS/DR Error Estimation for Autonomous Vehicle Localization

    PubMed Central

    Lee, Byung-Hyun; Song, Jong-Hwa; Im, Jun-Hyuck; Im, Sung-Hyuck; Heo, Moon-Beom; Jee, Gyu-In

    2015-01-01

    Autonomous vehicles require highly reliable navigation capabilities. For example, a lane-following method cannot be applied in an intersection without lanes, and since typical lane detection is performed using a straight-line model, errors can occur when the lateral distance is estimated in curved sections due to a model mismatch. Therefore, this paper proposes a localization method that uses GPS/DR error estimation based on a lane detection method with curved lane models, stop line detection, and curve matching in order to improve the performance during waypoint following procedures. The advantage of using the proposed method is that position information can be provided for autonomous driving through intersections, in sections with sharp curves, and in curved sections following a straight section. The proposed method was applied in autonomous vehicles at an experimental site to evaluate its performance, and the results indicate that the positioning achieved accuracy at the sub-meter level. PMID:26307997

  11. The contribution of simple random sampling to observed variations in faecal egg counts.

    PubMed

    Torgerson, Paul R; Paul, Michaela; Lewis, Fraser I

    2012-09-10

    It has been over 100 years since the classical paper published by Gosset in 1907, under the pseudonym "Student", demonstrated that yeast cells suspended in a fluid and measured by a haemocytometer conformed to a Poisson process. Similarly parasite eggs in a faecal suspension also conform to a Poisson process. Despite this there are common misconceptions how to analyse or interpret observations from the McMaster or similar quantitative parasitic diagnostic techniques, widely used for evaluating parasite eggs in faeces. The McMaster technique can easily be shown from a theoretical perspective to give variable results that inevitably arise from the random distribution of parasite eggs in a well mixed faecal sample. The Poisson processes that lead to this variability are described and illustrative examples of the potentially large confidence intervals that can arise from observed faecal eggs counts that are calculated from the observations on a McMaster slide. Attempts to modify the McMaster technique, or indeed other quantitative techniques, to ensure uniform egg counts are doomed to failure and belie ignorance of Poisson processes. A simple method to immediately identify excess variation/poor sampling from replicate counts is provided. Copyright © 2012 Elsevier B.V. All rights reserved.

  12. Method and apparatus for timing of laser beams in a multiple laser beam fusion system

    DOEpatents

    Eastman, Jay M.; Miller, Theodore L.

    1981-01-01

    The optical path lengths of a plurality of comparison laser beams directed to impinge upon a common target from different directions are compared to that of a master laser beam by using an optical heterodyne interferometric detection technique. The technique consists of frequency shifting the master laser beam and combining the master beam with a first one of the comparison laser beams to produce a time-varying heterodyne interference pattern which is detected by a photo-detector to produce an AC electrical signal indicative of the difference in the optical path lengths of the two beams which were combined. The optical path length of this first comparison laser beam is adjusted to compensate for the detected difference in the optical path lengths of the two beams. The optical path lengths of all of the comparison laser beams are made equal to the optical path length of the master laser beam by repeating the optical path length adjustment process for each of the comparison laser beams. In this manner, the comparison laser beams are synchronized or timed to arrive at the target within .+-.1.times.10.sup.-12 second of each other.

  13. Master plans for pedestrian and bicycle transportation: community characteristics.

    PubMed

    Steinman, Lesley; Doescher, Mark; Levinger, David; Perry, Cynthia; Carter, Louise; Eyler, Amy; Aytur, Semra; Cradock, Angie L I; Evenson, Kelly R; Heinrich, Katie; Kerr, Jacqueline; Litt, Jill; Severcan, Yucel; Voorhees, Carolyn

    2010-03-01

    Recent research demonstrates the importance of targeting the built environment to support individual physical activity, particularly for people experiencing health disparities. Master plans to promote biking and/or pedestrians (BPMPs) are a potential method for environmental change. This descriptive study aims to provide a snapshot of plan attributes and better understand demographic, social and transportation characteristics of communities with BPMPs. We collected a census sample of BPMPs from 4 states. Population and commuting data were obtained from national statistics. 294 master plans were included, with most plans representing municipalities. 62% of plans targeted biking only, one-fifth targeted biking and walking, and 15% targeted walking only. The sampled locations have a similar demographic profile as the overall U.S. for median age and household income, people of color, high school education, and income inequality. The degree of racial diversity of sampled communities is slightly less than the U.S. average and the percentage of people who walk to work were slightly higher. Given that communities with master plans have a similar profile as the overall U.S., BPMPs could feasibly be spread to communities throughout the country. Further research is planned to describe BPMPs in detail toward informing future plan development.

  14. Art-Based Learning Strategies in Art Therapy Graduate Education

    ERIC Educational Resources Information Center

    Deaver, Sarah P.

    2012-01-01

    This mixed methods research study examined the use of art-based teaching methods in master's level art therapy graduate education in North America. A survey of program directors yielded information regarding in which courses and how frequently art-based methods (individual in-class art making, dyad or group art making, student art projects as…

  15. A new method for calculating differential distributions directly in Mellin space

    NASA Astrophysics Data System (ADS)

    Mitov, Alexander

    2006-12-01

    We present a new method for the calculation of differential distributions directly in Mellin space without recourse to the usual momentum-fraction (or z-) space. The method is completely general and can be applied to any process. It is based on solving the integration-by-parts identities when one of the powers of the propagators is an abstract number. The method retains the full dependence on the Mellin variable and can be implemented in any program for solving the IBP identities based on algebraic elimination, like Laporta. General features of the method are: (1) faster reduction, (2) smaller number of master integrals compared to the usual z-space approach and (3) the master integrals satisfy difference instead of differential equations. This approach generalizes previous results related to fully inclusive observables like the recently calculated three-loop space-like anomalous dimensions and coefficient functions in inclusive DIS to more general processes requiring separate treatment of the various physical cuts. Many possible applications of this method exist, the most notable being the direct evaluation of the three-loop time-like splitting functions in QCD.

  16. Comparison of power curve monitoring methods

    NASA Astrophysics Data System (ADS)

    Cambron, Philippe; Masson, Christian; Tahan, Antoine; Torres, David; Pelletier, Francis

    2017-11-01

    Performance monitoring is an important aspect of operating wind farms. This can be done through the power curve monitoring (PCM) of wind turbines (WT). In the past years, important work has been conducted on PCM. Various methodologies have been proposed, each one with interesting results. However, it is difficult to compare these methods because they have been developed using their respective data sets. The objective of this actual work is to compare some of the proposed PCM methods using common data sets. The metric used to compare the PCM methods is the time needed to detect a change in the power curve. Two power curve models will be covered to establish the effect the model type has on the monitoring outcomes. Each model was tested with two control charts. Other methodologies and metrics proposed in the literature for power curve monitoring such as areas under the power curve and the use of statistical copulas have also been covered. Results demonstrate that model-based PCM methods are more reliable at the detecting a performance change than other methodologies and that the effectiveness of the control chart depends on the types of shift observed.

  17. Preparation of Al-La Master Alloy by Thermite Reaction in NaF-NaCl-KCl Molten Salt

    NASA Astrophysics Data System (ADS)

    Jang, Poknam; Li, Hyonmo; Kim, Wenjae; Wang, Zhaowen; Liu, Fengguo

    2015-05-01

    A NaF-NaCl-KCl ternary system containing La2O3 was investigated for the preparation of Al-La master alloy by the thermite reaction method. The solubility of La2O3 in NaF-NaCl-KCl molten salt was determined by the method of isothermal solution saturation. Inductively coupled plasma-optical emission spectroscopy and x-ray diffraction (XRD) analyses were used to consider the content of La2O3 in molten salt and the supernatant composition of molten salt after dissolution of La2O3, respectively. The results showed that the content of NaF had a positive influence on the solubility of La2O3 in NaF-NaCl-KCl molten salts, and the solubility of La2O3 could reach 8.71 wt.% in molten salts of 50 wt.%NaF-50 wt.% (44 wt.%NaCl + 56 wt.%KCl). The XRD pattern of cooling molten salt indicated the formation of LaOF in molten salt, which was probably obtained by the reaction between NaF and La2O3. The kinetic study showed that the thermite reaction was in accord with a first-order reaction model. The main influence factors on La content in the Al-La master alloy product, including molten salt composition, amount of Al, concentration of La2O3, stirring, reduction time and temperature, were investigated by single-factor experimentation. The content of La in the Al-La master alloy could be reached to 10.1 wt.%.

  18. Performance evaluation of a robot-assisted catheter operating system with haptic feedback.

    PubMed

    Song, Yu; Guo, Shuxiang; Yin, Xuanchun; Zhang, Linshuai; Hirata, Hideyuki; Ishihara, Hidenori; Tamiya, Takashi

    2018-06-20

    In this paper, a novel robot-assisted catheter operating system (RCOS) has been proposed as a method to reduce physical stress and X-ray exposure time to physicians during endovascular procedures. The unique design of this system allows the physician to apply conventional bedside catheterization skills (advance, retreat and rotate) to an input catheter, which is placed at the master side to control another patient catheter placed at the slave side. For this purpose, a magnetorheological (MR) fluids-based master haptic interface has been developed to measure the axial and radial motions of an input catheter, as well as to provide the haptic feedback to the physician during the operation. In order to achieve a quick response of the haptic force in the master haptic interface, a hall sensor-based closed-loop control strategy is employed. In slave side, a catheter manipulator is presented to deliver the patient catheter, according to position commands received from the master haptic interface. The contact forces between the patient catheter and blood vessel system can be measured by designed force sensor unit of catheter manipulator. Four levels of haptic force are provided to make the operator aware of the resistance encountered by the patient catheter during the insertion procedure. The catheter manipulator was evaluated for precision positioning. The time lag from the sensed motion to replicated motion is tested. To verify the efficacy of the proposed haptic feedback method, the evaluation experiments in vitro are carried out. The results demonstrate that the proposed system has the ability to enable decreasing the contact forces between the catheter and vasculature.

  19. [Application of problem-based learning in pre-job training of postgraduate students in department of endodontics].

    PubMed

    Shao, Li-na; Wang, Xue-mei; Qiu, Li-hong; Zhan, Fu-liang; Xue, Ming

    2013-08-01

    To apply problem-based learning (PBL) in pre-job training of postgraduate students in department of endodontics. Thirty master degree postgraduate students of China Medical University were randomly divided into 2 groups, there were 15 students in each group. One group were taught with PBL method while the other group with lecture-based learning (LBL) method. The teaching effect was measured with examination and questionnaire survey. The data were analyzed by student's t-test using SPSS 11.5 software package. There was no significant difference in basic knowledge, medical records writing, oral examination between the two groups (P>0.05). There were significant differences in case analysis, dental operation, theory examination, practical examination and total scores between the two groups (P<0.05). The PBL method was welcomed by master degree postgraduate students. The abilities of postgraduate students can be developed by PBL method in different aspects. PBL achieves satisfactory teaching effect, and can be applied in pre-job training of postgraduate students.

  20. Edge detection and mathematic fitting for corneal surface with Matlab software.

    PubMed

    Di, Yue; Li, Mei-Yan; Qiao, Tong; Lu, Na

    2017-01-01

    To select the optimal edge detection methods to identify the corneal surface, and compare three fitting curve equations with Matlab software. Fifteen subjects were recruited. The corneal images from optical coherence tomography (OCT) were imported into Matlab software. Five edge detection methods (Canny, Log, Prewitt, Roberts, Sobel) were used to identify the corneal surface. Then two manual identifying methods (ginput and getpts) were applied to identify the edge coordinates respectively. The differences among these methods were compared. Binomial curve (y=Ax 2 +Bx+C), Polynomial curve [p(x)=p1x n +p2x n-1 +....+pnx+pn+1] and Conic section (Ax 2 +Bxy+Cy 2 +Dx+Ey+F=0) were used for curve fitting the corneal surface respectively. The relative merits among three fitting curves were analyzed. Finally, the eccentricity (e) obtained by corneal topography and conic section were compared with paired t -test. Five edge detection algorithms all had continuous coordinates which indicated the edge of the corneal surface. The ordinates of manual identifying were close to the inside of the actual edges. Binomial curve was greatly affected by tilt angle. Polynomial curve was lack of geometrical properties and unstable. Conic section could calculate the tilted symmetry axis, eccentricity, circle center, etc . There were no significant differences between 'e' values by corneal topography and conic section ( t =0.9143, P =0.3760 >0.05). It is feasible to simulate the corneal surface with mathematical curve with Matlab software. Edge detection has better repeatability and higher efficiency. The manual identifying approach is an indispensable complement for detection. Polynomial and conic section are both the alternative methods for corneal curve fitting. Conic curve was the optimal choice based on the specific geometrical properties.

  1. Application of a Novel DCPD Adjustment Method for the J-R Curve Characterization: A study based on ORNL and ASTM Interlaboratory Results

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Chen, Xiang; Sokolov, Mikhail A; Nanstad, Randy K

    Material fracture toughness in the fully ductile region can be described by a J-integral vs. crack growth resistance curve (J-R curve). As a conventional J-R curve measurement method, the elastic unloading compliance (EUC) method becomes impractical for elevated temperature testing due to relaxation of the material and friction induced back-up shape of the J-R curve. One alternative solution of J-R curve testing applies the Direct Current Potential Drop (DCPD) technique for measuring crack extension. However, besides crack growth, potential drop can also be influenced by plastic deformation, crack tip blunting, etc., and uncertainties exist in the current DCPD methodology especiallymore » in differentiating potential drop due to stable crack growth and due to material deformation. Thus, using DCPD for J-R curve determination remains a challenging task. In this study, a new adjustment procedure for applying DCPD to derive the J-R curve has been developed for conventional fracture toughness specimens, including compact tension, three-point bend, and disk-shaped compact specimens. Data analysis has been performed on Oak Ridge National Laboratory (ORNL) and American Society for Testing and Materials (ASTM) interlaboratory results covering different specimen thicknesses, test temperatures, and materials, to evaluate the applicability of the new DCPD adjustment procedure for J-R curve characterization. After applying the newly-developed procedure, direct comparison between the DCPD method and the normalization method on the same specimens indicated close agreement for the overall J-R curves, as well as the provisional values of fracture toughness near the onset of ductile crack extension, Jq, and of tearing modulus.« less

  2. A Novel Videography Method for Generating Crack-Extension Resistance Curves in Small Bone Samples

    PubMed Central

    Katsamenis, Orestis L.; Jenkins, Thomas; Quinci, Federico; Michopoulou, Sofia; Sinclair, Ian; Thurner, Philipp J.

    2013-01-01

    Assessment of bone quality is an emerging solution for quantifying the effects of bone pathology or treatment. Perhaps one of the most important parameters characterising bone quality is the toughness behaviour of bone. Particularly, fracture toughness, is becoming a popular means for evaluating bone quality. The method is moving from a single value approach that models bone as a linear-elastic material (using the stress intensity factor, K) towards full crack extension resistance curves (R-curves) using a non-linear model (the strain energy release rate in J-R curves). However, for explanted human bone or small animal bones, there are difficulties in measuring crack-extension resistance curves due to size constraints at the millimetre and sub-millimetre scale. This research proposes a novel “whitening front tracking” method that uses videography to generate full fracture resistance curves in small bone samples where crack propagation cannot typically be observed. Here we present this method on sharp edge notched samples (<1 mm×1 mm×Length) prepared from four human femora tested in three-point bending. Each sample was loaded in a mechanical tester with the crack propagation recorded using videography and analysed using an algorithm to track the whitening (damage) zone. Using the “whitening front tracking” method, full R-curves and J-R curves could be generated for these samples. The curves for this antiplane longitudinal orientation were similar to those found in the literature, being between the published longitudinal and transverse orientations. The proposed technique shows the ability to generate full “crack” extension resistance curves by tracking the whitening front propagation to overcome the small size limitations and the single value approach. PMID:23405186

  3. A new method for the automatic interpretation of Schlumberger and Wenner sounding curves

    USGS Publications Warehouse

    Zohdy, A.A.R.

    1989-01-01

    A fast iterative method for the automatic interpretation of Schlumberger and Wenner sounding curves is based on obtaining interpreted depths and resistivities from shifted electrode spacings and adjusted apparent resistivities, respectively. The method is fully automatic. It does not require an initial guess of the number of layers, their thicknesses, or their resistivities; and it does not require extrapolation of incomplete sounding curves. The number of layers in the interpreted model equals the number of digitized points on the sounding curve. The resulting multilayer model is always well-behaved with no thin layers of unusually high or unusually low resistivities. For noisy data, interpretation is done in two sets of iterations (two passes). Anomalous layers, created because of noise in the first pass, are eliminated in the second pass. Such layers are eliminated by considering the best-fitting curve from the first pass to be a smoothed version of the observed curve and automatically reinterpreting it (second pass). The application of the method is illustrated by several examples. -Author

  4. Dynamic control modification techniques in teleoperation of a flexible manipulator. M.S. Thesis

    NASA Technical Reports Server (NTRS)

    Magee, David Patrick

    1991-01-01

    The objective of this research is to reduce the end-point vibration of a large, teleoperated manipulator while preserving the usefulness of the system motion. A master arm is designed to measure desired joint angles as the user specifies a desired tip motion. The desired joint angles from the master arm are the inputs to an adaptive PD control algorithm that positions the end-point of the manipulator. As the user moves the tip of the master, the robot will vibrate at its natural frequencies which makes it difficult to position the end-point. To eliminate the tip vibration during teleoperated motions, an input shaping method is presented. The input shaping method transforms each sample of the desired input into a new set of impulses that do not excite the system resonances. The method is explained using the equation of motion for a simple, second-order system. The impulse response of such a system is derived and the constraint equations for vibrationless motion are presented. To evaluate the robustness of the method, a different residual vibration equation from Singer's is derived that more accurately represents the input shaping technique. The input shaping method is shown to actually increase the residual vibration in certain situations when the system parameters are not accurately specified. Finally, the implementation of the input shaping method to a system with varying parameters is shown to induce a vibration into the system. To eliminate this vibration, a modified command shaping technique is developed. The ability of the modified command shaping method to reduce vibration at the system resonances is tested by varying input perturbations to trajectories in a range of possible user inputs. By comparing the frequency responses of the transverse acceleration at the end-point of the manipulator, the modified method is compared to the original PD routine. The control scheme that produces the smaller magnitude of resonant vibration at the first natural frequency is considered the more effective control method.

  5. Interconversion of mechanical and dielectrical relaxation measurements for dicyclohexylmethyl-2-methyl succinate.

    PubMed

    Díaz-Calleja, R; Garcia-Bernabé, A; Sanchis, M J; del Castillo, L F

    2005-11-01

    A comparison between results of dielectrical relaxation and dynamic mechanical spectroscopies is carried out for the alpha-relaxation of the ester dicyclohexyl methyl-2-methyl succinate (DCMMS). The results for the dielectric permittivity and the shear modulus measurements are presented according to the empirical Havriliak-Negami (HN) equation. By using the time-temperature principle a master curve in each case was obtained for several temperatures. The comparative analysis presented here is based on the assumption of a relationship between rotational and shear viscosities. The former one is associated to the dielectrical relaxation, whereas the latter is associated to mechanical relaxation. Both viscosities are not necessarily equal in general, and we assume that the difference between them is an important factor to appropriately compare the dielectrical and mechanical results.

  6. Interactions between silica particles in the presence of multivalent coions.

    PubMed

    Uzelac, Biljana; Valmacco, Valentina; Trefalt, Gregor

    2017-08-30

    Forces between charged silica particles in solutions of multivalent coions are measured with colloidal probe technique based on atomic force microscopy. The concentration of 1 : z electrolytes is systematically varied to understand the behavior of electrostatic interactions and double-layer properties in these systems. Although the coions are multivalent the Derjaguin, Landau, Verwey, and Overbeek (DLVO) theory perfectly describes the measured force profiles. The diffuse-layer potentials and regulation properties are extracted from the forces profiles by using the DLVO theory. The dependencies of the diffuse-layer potential and regulation parameter shift to lower concentration with increasing coion valence when plotted as a function of concentration of 1 : z salt. Interestingly, these profiles collapse to a master curve if plotted as a function of monovalent counterion concentration.

  7. Pressure Effect on the Boson Peak in Deeply Cooled Confined Water: Evidence of a Liquid-Liquid Transition.

    PubMed

    Wang, Zhe; Kolesnikov, Alexander I; Ito, Kanae; Podlesnyak, Andrey; Chen, Sow-Hsin

    2015-12-04

    The boson peak in deeply cooled water confined in nanopores is studied to examine the liquid-liquid transition (LLT). Below ∼180  K, the boson peaks at pressures P higher than ∼3.5  kbar are evidently distinct from those at low pressures by higher mean frequencies and lower heights. Moreover, the higher-P boson peaks can be rescaled to a master curve while the lower-P boson peaks can be rescaled to a different one. These phenomena agree with the existence of two liquid phases with different densities and local structures and the associated LLT in the measured (P, T) region. In addition, the P dependence of the librational band also agrees with the above conclusion.

  8. Epidemic spreading in a hierarchical social network.

    PubMed

    Grabowski, A; Kosiński, R A

    2004-09-01

    A model of epidemic spreading in a population with a hierarchical structure of interpersonal interactions is described and investigated numerically. The structure of interpersonal connections is based on a scale-free network. Spatial localization of individuals belonging to different social groups, and the mobility of a contemporary community, as well as the effectiveness of different interpersonal interactions, are taken into account. Typical relations characterizing the spreading process, like a range of epidemic and epidemic curves, are discussed. The influence of preventive vaccinations on the spreading process is investigated. The critical value of preventively vaccinated individuals that is sufficient for the suppression of an epidemic is calculated. Our results are compared with solutions of the master equation for the spreading process and good agreement of the character of this process is found.

  9. Scaling Behavior for Ionic Transport and its Fluctuations in Individual Carbon Nanotubes.

    PubMed

    Secchi, Eleonora; Niguès, Antoine; Jubin, Laetitia; Siria, Alessandro; Bocquet, Lydéric

    2016-04-15

    In this Letter, we perform an experimental study of ionic transport and current fluctuations inside individual carbon nanotubes (CNTs). The conductance exhibits a power law behavior at low salinity, with an exponent close to 1/3 versus the salt concentration in this regime. This behavior is rationalized in terms of a salinity dependent surface charge, which is accounted for on the basis of a model for hydroxide adsorption at the (hydrophobic) carbon surface. This is in contrast to boron nitride nanotubes which exhibit a constant surface conductance. Further, we measure the low frequency noise of the ionic current in CNTs and show that the amplitude of the noise scales with the surface charge, with data collapsing on a master curve for the various studied CNTs at a given pH.

  10. Scaling Behavior for Ionic Transport and its Fluctuations in Individual Carbon Nanotubes

    NASA Astrophysics Data System (ADS)

    Secchi, Eleonora; Niguès, Antoine; Jubin, Laetitia; Siria, Alessandro; Bocquet, Lydéric

    2016-04-01

    In this Letter, we perform an experimental study of ionic transport and current fluctuations inside individual carbon nanotubes (CNTs). The conductance exhibits a power law behavior at low salinity, with an exponent close to 1 /3 versus the salt concentration in this regime. This behavior is rationalized in terms of a salinity dependent surface charge, which is accounted for on the basis of a model for hydroxide adsorption at the (hydrophobic) carbon surface. This is in contrast to boron nitride nanotubes which exhibit a constant surface conductance. Further, we measure the low frequency noise of the ionic current in CNTs and show that the amplitude of the noise scales with the surface charge, with data collapsing on a master curve for the various studied CNTs at a given p H .

  11. Equilibrium concentration profiles and sedimentation kinetics of colloidal gels under gravitational stress

    NASA Astrophysics Data System (ADS)

    Buzzaccaro, S.; Secchi, E.; Brambilla, G.; Piazza, R.; Cipelletti, L.

    2012-07-01

    We study the sedimentation of colloidal gels by using a combination of light scattering, polarimetry and video imaging. The asymptotic concentration profiles φ(z,t → ∞) exhibit remarkable scaling properties: profiles for gels prepared at different initial volume fractions and particle interactions can be superimposed onto a single master curve by using suitable reduced variables. We show theoretically that this behavior stems from a power law dependence of the compressive elastic modulus versus φ, which we directly test experimentally. The sedimentation kinetics comprises an initial latency stage, followed by a rapid collapse where the gel height h decreases at constant velocity and a final compaction stage characterized by a stretched exponential relaxation of h toward a plateau. Analogies and differences with previous works are briefly discussed.

  12. Pressure Effect on the Boson Peak in Deeply Cooled Confined Water: Evidence of a Liquid-Liquid Transition

    DOE PAGES

    Wang, Zhe; Kolesnikov, Alexander I.; Ito, Kanae; ...

    2015-12-03

    We studied the boson peak in deeply cooled water confined in nanopores in order to examine the liquid-liquid transition (LLT). Below ~180 K, the boson peaks at pressures P higher than ~3.5 kbar are evidently distinct from those at low pressures by higher mean frequencies and lower heights. Moreover, the higher-P boson peaks can be rescaled to a master curve while the lower-P boson peaks can be rescaled to a different one. Moreover, these phenomena agree with the existence of two liquid phases with different densities and local structures and the associated LLT in the measured (P, T) region. Additionally,more » the P dependence of the librational band also agrees with the above conclusion.« less

  13. Strain-rate/temperature behavior of high density polyethylene in compression

    NASA Technical Reports Server (NTRS)

    Clements, L. L.; Sherby, O. D.

    1978-01-01

    The compressive strain rate/temperature behavior of highly linear, high density polyethylene was analyzed in terms of the predictive relations developed for metals and other crystalline materials. For strains of 5 percent and above, the relationship between applied strain rate, dotted epsilon, and resulting flow stress, sigma, was found to be: dotted epsilon exp times (Q sub f/RT) = k'(sigma/sigma sub c) to the nth power; the left-hand side is the activation-energy-compensated strain rate, where Q sub f is activation energy for flow, R is gas constant, and T is temperature; k is a constant, n is temperature-independent stress exponent, and sigma/sigma sub c is structure-compensated stress. A master curve resulted from a logarithmic plot of activation-energy-compensated strain rate versus structure-compensated stress.

  14. [The visual perception of the elements of technical drawings among masking distractions in advanced and nonadvanced students in the building and architectural professions].

    PubMed

    Balichev, Iu

    1997-01-01

    To investigation were submitted the particularities of the process of visual perception of technical drawings and schemes in advanced and backward pupils, who were mastering the specialties of "building and architecture", "hydroconstruction", "transport construction", "geodesy". The time was registered, which was necessary to advanced and backward pupils for unveiling the different elements in the drawing, scheme, and such attributes of the drawing as: orientation, length, curves of the lined, the boundary between them; time for identification of the specific designations, symbols, group of symbols, elements of the sketch from the simple to the complex ones. The results of the investigations revealed that in the advanced pupils the perception (unveiling) of the different elements of the technical drawing proceeded very rapidly, almost automatically. In the backward pupils this process elapsed reliably more slowly. It was demonstrated that the growing up pupils, who were distinguished with more rapid perception of the different elements of the drawing (advanced ones) more rapidly and more exactly dealt with solution of the technical tasks as compared with these, who more slowly unveiled the looked for elements (backwardness). Some other individual particularities were also established with respect to the visual perception of the elements of the technical drawing and its properties in advanced and backward pupils who were mastering the investigated professions.

  15. Robotic invasion of operation theatre and associated anaesthetic issues: A review.

    PubMed

    Kakar, Prem N; Das, Jyotirmoy; Roy, Preeti Mittal; Pant, Vijaya

    2011-01-01

    A Robotic device is a powered, computer controlled manipulator with artificial sensing that can be reprogrammed to move and position tools to carry out a wide range of tasks. Robots and Telemanipulators were first developed by the National Aeronautics and Space Administration (NASA) for use in space exploration. Today's medical robotic systems were the brainchild of the United States Department of Defence's desire to decrease war casualties with the development of 'telerobotic surgery'. The 'master-slave' telemanipulator concept was developed for medical use in the early 1990s where the surgeon's (master) manual movements were transmitted to end-effector (slave) instruments at a remote site. Since then, the field of surgical robotics has undergone massive transformation and the future is even brighter. As expected, any new technique brings with it risks and the possibility of technical difficulties. The person who bears the brunt of complications or benefit from a new invention is the 'Patient'. Anaesthesiologists as always must do their part to be the patient's 'best man' in the perioperative period. We should be prepared for screening and selection of patients in a different perspective keeping in mind the steep learning curves of surgeons, long surgical hours, extreme patient positioning and other previously unknown anaesthetic challenges brought about by the surgical robot. In this article we have tried to track the development of surgical robots and consider the unique anaesthetic issues related to robot assisted surgeries.

  16. Can the pre-operative Western Ontario and McMaster score predict patient satisfaction following total hip arthroplasty?

    PubMed

    Rogers, B A; Alolabi, B; Carrothers, A D; Kreder, H J; Jenkinson, R J

    2015-02-01

    In this study we evaluated whether pre-operative Western Ontario and McMaster Universities (WOMAC) osteoarthritis scores can predict satisfaction following total hip arthroplasty (THA). Prospective data for a cohort of patients undergoing THA from two large academic centres were collected, and pre-operative and one-year post-operative WOMAC scores and a 25-point satisfaction questionnaire were obtained for 446 patients. Satisfaction scores were dichotomised into either improvement or deterioration. Scatter plots and Spearman's rank correlation coefficient were used to describe the association between pre-operative WOMAC and one-year post-operative WOMAC scores and patient satisfaction. Satisfaction was compared using receiver operating characteristic (ROC) analysis against pre-operative, post-operative and δ WOMAC scores. We found no relationship between pre-operative WOMAC scores and one-year post-operative WOMAC or satisfaction scores, with Spearman's rank correlation coefficients of 0.16 and -0.05, respectively. The ROC analysis showed areas under the curve (AUC) of 0.54 (pre-operative WOMAC), 0.67 (post-operative WOMAC) and 0.43 (δ WOMAC), respectively, for an improvement in satisfaction. We conclude that the pre-operative WOMAC score does not predict the post-operative WOMAC score or patient satisfaction after THA, and that WOMAC scores can therefore not be used to prioritise patient care. ©2015 The British Editorial Society of Bone & Joint Surgery.

  17. Evidence-based selection process to the Master of Public Health program at Medical University.

    PubMed

    Panczyk, Mariusz; Juszczyk, Grzegorz; Zarzeka, Aleksander; Samoliński, Łukasz; Belowska, Jarosława; Cieślak, Ilona; Gotlib, Joanna

    2017-09-11

    Evaluation of the predictive validity of selected sociodemographic factors and admission criteria for Master's studies in Public Health at the Faculty of Health Sciences, Medical University of Warsaw (MUW). For the evaluation purposes recruitment data and learning results of students enrolled between 2008 and 2012 were used (N = 605, average age 22.9 ± 3.01). The predictive analysis was performed using the multiple linear regression method. In the proposed regression model 12 predictors were selected, including: sex, age, professional degree (BA), the Bachelor's studies grade point average (GPA), total score of the preliminary examination broken down into five thematic areas. Depending on the tested model, one of two dependent variables was used: first-year GPA or cumulative GPA in the Master program. The regression model based on the result variable of Master's GPA program was better matched to data in comparison to the model based on the first year GPA (adjusted R 2 0.413 versus 0.476 respectively). The Bachelor's studies GPA and each of the five subtests comprising the test entrance exam were significant predictors of success achieved by a student both after the first year and at the end of the course of studies. Criteria of admissions with total score of MCQs exam and Bachelor's studies GPA can be successfully used for selection of the candidates for Master's degree studies in Public Health. The high predictive validity of the recruitment system confirms the validity of the adopted admission policy at MUW.

  18. Identification of lactic acid bacteria isolated from wine using real-time PCR.

    PubMed

    Kántor, Attila; Kluz, Maciej; Puchalski, Czeslaw; Terentjeva, Margarita; Kačániová, Miroslava

    2016-01-01

    Different lactic acid bacteria strains have been shown to cause wine spoilage, including the generation of substances undesirable for the health of wine consumers. The aim of this study was to investigate the occurrence of selected species of heterofermentative lactobacilli, specifically Lactobacillus brevis, Lactobacillus hilgardii, and Lactobacillus plantarum in six different Slovak red wines following the fermentation process. In order to identify the dominant Lactobacillus strain using quantitative (real time) polymerized chain reaction (qPCR) method, pure lyophilized bacterial cultures from the Czech Collection of Microorganisms were used. Six different red wine samples following malolactic fermentation were obtained from selected wineries. After collection, the samples were subjected to a classic plate dilution method for enumeration of lactobacilli cells. Real-time PCR was performed after DNA extraction from pure bacterial strains and wine samples. We used SYBR® Green master mix reagents for measuring the fluorescence in qPCR. The number of lactobacilli ranged from 3.60 to 5.02 log CFU mL(-1). Specific lactobacilli strains were confirmed by qPCR in all wine samples. The number of lactobacilli ranged from 10(3) to 10(6) CFU mL(-1). A melting curve with different melting temperatures (T(m)) of DNA amplicons was obtained after PCR for the comparison of T(m) of control and experimental portions, revealing that the most common species in wine samples was Lactobacillus plantarum with a T(m) of 84.64°C.

  19. Decomposition and correction overlapping peaks of LIBS using an error compensation method combined with curve fitting.

    PubMed

    Tan, Bing; Huang, Min; Zhu, Qibing; Guo, Ya; Qin, Jianwei

    2017-09-01

    The laser induced breakdown spectroscopy (LIBS) technique is an effective method to detect material composition by obtaining the plasma emission spectrum. The overlapping peaks in the spectrum are a fundamental problem in the qualitative and quantitative analysis of LIBS. Based on a curve fitting method, this paper studies an error compensation method to achieve the decomposition and correction of overlapping peaks. The vital step is that the fitting residual is fed back to the overlapping peaks and performs multiple curve fitting processes to obtain a lower residual result. For the quantitative experiments of Cu, the Cu-Fe overlapping peaks in the range of 321-327 nm obtained from the LIBS spectrum of five different concentrations of CuSO 4 ·5H 2 O solution were decomposed and corrected using curve fitting and error compensation methods. Compared with the curve fitting method, the error compensation reduced the fitting residual about 18.12-32.64% and improved the correlation about 0.86-1.82%. Then, the calibration curve between the intensity and concentration of the Cu was established. It can be seen that the error compensation method exhibits a higher linear correlation between the intensity and concentration of Cu, which can be applied to the decomposition and correction of overlapping peaks in the LIBS spectrum.

  20. Exponential synchronization of neural networks with discrete and distributed delays under time-varying sampling.

    PubMed

    Wu, Zheng-Guang; Shi, Peng; Su, Hongye; Chu, Jian

    2012-09-01

    This paper investigates the problem of master-slave synchronization for neural networks with discrete and distributed delays under variable sampling with a known upper bound on the sampling intervals. An improved method is proposed, which captures the characteristic of sampled-data systems. Some delay-dependent criteria are derived to ensure the exponential stability of the error systems, and thus the master systems synchronize with the slave systems. The desired sampled-data controller can be achieved by solving a set of linear matrix inequalitys, which depend upon the maximum sampling interval and the decay rate. The obtained conditions not only have less conservatism but also have less decision variables than existing results. Simulation results are given to show the effectiveness and benefits of the proposed methods.

  1. Modeling Interoperable Information Systems with 3LGM² and IHE.

    PubMed

    Stäubert, S; Schaaf, M; Jahn, F; Brandner, R; Winter, A

    2015-01-01

    Strategic planning of information systems (IS) in healthcare requires descriptions of the current and the future IS state. Enterprise architecture planning (EAP) tools like the 3LGM² tool help to build up and to analyze IS models. A model of the planned architecture can be derived from an analysis of current state IS models. Building an interoperable IS, i. e. an IS consisting of interoperable components, can be considered a relevant strategic information management goal for many IS in healthcare. Integrating the healthcare enterprise (IHE) is an initiative which targets interoperability by using established standards. To link IHE concepts to 3LGM² concepts within the 3LGM² tool. To describe how an information manager can be supported in handling the complex IHE world and planning interoperable IS using 3LGM² models. To describe how developers or maintainers of IHE profiles can be supported by the representation of IHE concepts in 3LGM². Conceptualization and concept mapping methods are used to assign IHE concepts such as domains, integration profiles actors and transactions to the concepts of the three-layer graph-based meta-model (3LGM²). IHE concepts were successfully linked to 3LGM² concepts. An IHE-master-model, i. e. an abstract model for IHE concepts, was modeled with the help of 3LGM² tool. Two IHE domains were modeled in detail (ITI, QRPH). We describe two use cases for the representation of IHE concepts and IHE domains as 3LGM² models. Information managers can use the IHE-master-model as reference model for modeling interoperable IS based on IHE profiles during EAP activities. IHE developers are supported in analyzing consistency of IHE concepts with the help of the IHE-master-model and functions of the 3LGM² tool The complex relations between IHE concepts can be modeled by using the EAP method 3LGM². 3LGM² tool offers visualization and analysis features which are now available for the IHE-master-model. Thus information managers and IHE developers can use or develop IHE profiles systematically. In order to improve the usability and handling of the IHE-master-model and its usage as a reference model, some further refinements have to be done. Evaluating the use of the IHE-master-model by information managers and IHE developers is subject to further research.

  2. Finding Planets in K2: A New Method of Cleaning the Data

    NASA Astrophysics Data System (ADS)

    Currie, Miles; Mullally, Fergal; Thompson, Susan E.

    2017-01-01

    We present a new method of removing systematic flux variations from K2 light curves by employing a pixel-level principal component analysis (PCA). This method decomposes the light curves into its principal components (eigenvectors), each with an associated eigenvalue, the value of which is correlated to how much influence the basis vector has on the shape of the light curve. This method assumes that the most influential basis vectors will correspond to the unwanted systematic variations in the light curve produced by K2’s constant motion. We correct the raw light curve by automatically fitting and removing the strongest principal components. The strongest principal components generally correspond to the flux variations that result from the motion of the star in the field of view. Our primary method of calculating the strongest principal components to correct for in the raw light curve estimates the noise by measuring the scatter in the light curve after using an algorithm for Savitsy-Golay detrending, which computes the combined photometric precision value (SG-CDPP value) used in classic Kepler. We calculate this value after correcting the raw light curve for each element in a list of cumulative sums of principal components so that we have as many noise estimate values as there are principal components. We then take the derivative of the list of SG-CDPP values and take the number of principal components that correlates to the point at which the derivative effectively goes to zero. This is the optimal number of principal components to exclude from the refitting of the light curve. We find that a pixel-level PCA is sufficient for cleaning unwanted systematic and natural noise from K2’s light curves. We present preliminary results and a basic comparison to other methods of reducing the noise from the flux variations.

  3. ADVANCED INTEGRATION OF MULTI-SCALE MECHANICS AND WELDING PROCESS SIMULATION IN WELD INTEGRITY ASSESSMENT

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Wilkowski, Gery M.; Rudland, David L.; Shim, Do-Jun

    2008-06-30

    The potential to save trillions of BTU’s in energy usage and billions of dollars in cost on an annual basis based on use of higher strength steel in major oil and gas transmission pipeline construction is a compelling opportunity recognized by both the US Department of Energy (DOE). The use of high-strength steels (X100) is expected to result in energy savings across the spectrum, from manufacturing the pipe to transportation and fabrication, including welding of line pipe. Elementary examples of energy savings include more the 25 trillion BTUs saved annually based on lower energy costs to produce the thinner-walled high-strengthmore » steel pipe, with the potential for the US part of the Alaskan pipeline alone saving more than 7 trillion BTU in production and much more in transportation and assembling. Annual production, maintenance and installation of just US domestic transmission pipeline is likely to save 5 to 10 times this amount based on current planned and anticipated expansions of oil and gas lines in North America. Among the most important conclusions from these studies were: • While computational weld models to predict residual stress and distortions are well-established and accurate, related microstructure models need improvement. • Fracture Initiation Transition Temperature (FITT) Master Curve properly predicts surface-cracked pipe brittle-to-ductile initiation temperature. It has value in developing Codes and Standards to better correlate full-scale behavior from either CTOD or Charpy test results with the proper temperature shifts from the FITT master curve method. • For stress-based flaw evaluation criteria, the new circumferentially cracked pipe limit-load solution in the 2007 API 1104 Appendix A approach is overly conservative by a factor of 4/π, which has additional implications. . • For strain-based design of girth weld defects, the hoop stress effect is the most significant parameter impacting CTOD-driving force and can increase the crack-driving force by a factor of 2 depending on strain-hardening, pressure level as a % of SMYS, and flaw size. • From years of experience in circumferential fracture analyses and experimentation, there has not been sufficient integration of work performed for other industries into analogous problems facing the oil and gas pipeline markets. Some very basic concepts and problems solved previously in these fields could have circumvented inconsistencies seen in the stress-based and strain-based analysis efforts. For example, in nuclear utility piping work, more detailed elastic-plastic fracture analyses were always validated in their ability to predict loads and displacements (stresses and strains). The eventual implementation of these methodologies will result in acceleration of the industry adoption of higher-strength line-pipe steels.« less

  4. Brain activation in parietal area during manipulation with a surgical robot simulator.

    PubMed

    Miura, Satoshi; Kobayashi, Yo; Kawamura, Kazuya; Nakashima, Yasutaka; Fujie, Masakatsu G

    2015-06-01

    we present an evaluation method to qualify the embodiment caused by the physical difference between master-slave surgical robots by measuring the activation of the intraparietal sulcus in the user's brain activity during surgical robot manipulation. We show the change of embodiment based on the change of the optical axis-to-target view angle in the surgical simulator to change the manipulator's appearance in the monitor in terms of hand-eye coordination. The objective is to explore the change of brain activation according to the change of the optical axis-to-target view angle. In the experiments, we used a functional near-infrared spectroscopic topography (f-NIRS) brain imaging device to measure the brain activity of the seven subjects while they moved the hand controller to insert a curved needle into a target using the manipulator in a surgical simulator. The experiment was carried out several times with a variety of optical axis-to-target view angles. Some participants showed a significant peak (P value = 0.037, F-number = 2.841) when the optical axis-to-target view angle was 75°. The positional relationship between the manipulators and endoscope at 75° would be the closest to the human physical relationship between the hands and eyes.

  5. Modeling the locomotion of the African trypanosome using multi-particle collision dynamics

    NASA Astrophysics Data System (ADS)

    Babu, Sujin B.; Stark, Holger

    2012-08-01

    The African trypanosome is a single flagellated micro-organism that causes the deadly sleeping sickness in humans and animals. We study the locomotion of a model trypanosome by modeling the spindle-shaped cell body using an elastic network of vertices with additional bending rigidity. The flagellum firmly attached to the model cell body is either straight or helical. A bending wave propagates along the flagellum and pushes the trypanosome forward in its viscous environment, which we simulate with the method of multi-particle collision dynamics. The relaxation dynamics of the model cell body due to a static bending wave reveals the sperm number from elastohydrodynamics as the relevant parameter. Characteristic cell body conformations for the helically attached flagellum resemble experimental observations. We show that the swimming velocity scales as the root of the angular frequency of the bending wave reminiscent of predictions for an actuated slender rod attached to a large viscous load. The swimming velocity for one geometry collapses on a single master curve when plotted versus the sperm number. The helically attached flagellum leads to a helical swimming path and a rotation of the model trypanosome about its long axis as observed in experiments. The simulated swimming velocity agrees with the experimental value.

  6. SU-G-206-17: RadShield: Semi-Automated Shielding Design for CT Using NCRP 147 and Isodose Curves

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    DeLorenzo, M; Rutel, I; Yang, K

    2016-06-15

    Purpose: Computed tomography (CT) exam rooms are shielded more quickly and accurately compared to manual calculations using RadShield, a semi-automated diagnostic shielding software package. Last year, we presented RadShield’s approach to shielding radiographic and fluoroscopic rooms calculating air kerma rate and barrier thickness at many points on the floor plan and reporting the maximum values for each barrier. RadShield has now been expanded to include CT shielding design using not only NCRP 147 methodology but also by overlaying vendor provided isodose curves onto the floor plan. Methods: The floor plan image is imported onto the RadShield workspace to serve asmore » a template for drawing barriers, occupied regions and CT locations. SubGUIs are used to set design goals, occupancy factors, workload, and overlay isodose curve files. CTDI and DLP methods are solved following NCRP 147. RadShield’s isodose curve method employs radial scanning to extract data point sets to fit kerma to a generalized power law equation of the form K(r) = ar^b. RadShield’s semiautomated shielding recommendations were compared against a board certified medical physicist’s design using dose length product (DLP) and isodose curves. Results: The percentage error found between the physicist’s manual calculation and RadShield’s semi-automated calculation of lead barrier thickness was 3.42% and 21.17% for the DLP and isodose curve methods, respectively. The medical physicist’s selection of calculation points for recommending lead thickness was roughly the same as those found by RadShield for the DLP method but differed greatly using the isodose method. Conclusion: RadShield improves accuracy in calculating air-kerma rate and barrier thickness over manual calculations using isodose curves. Isodose curves were less intuitive and more prone to error for the physicist than inverse square methods. RadShield can now perform shielding design calculations for general scattering bodies for which isodose curves are provided.« less

  7. SU-F-P-53: RadShield: Semi-Automated Shielding Design for CT Using NCRP 147 and Isodose Curves

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    DeLorenzo, M; Rutel, I; Wu, D

    Purpose: Computed tomography (CT) exam rooms are shielded more quickly and accurately compared to manual calculations using RadShield, a semi-automated diagnostic shielding software package. Last year, we presented RadShield’s approach to shielding radiographic and fluoroscopic rooms calculating air kerma rate and barrier thickness at many points on the floor plan and reporting the maximum values for each barrier. RadShield has now been expanded to include CT shielding design using not only NCRP 147 methodology but also by overlaying vendor provided isodose curves onto the floor plan. Methods: The floor plan image is imported onto the RadShield workspace to serve asmore » a template for drawing barriers, occupied regions and CT locations. SubGUIs are used to set design goals, occupancy factors, workload, and overlay isodose curve files. CTDI and DLP methods are solved following NCRP 147. RadShield’s isodose curve method employs radial scanning to extract data point sets to fit kerma to a generalized power law equation of the form K(r) = ar^b. RadShield’s semi-automated shielding recommendations were compared against a board certified medical physicist’s design using dose length product (DLP) and isodose curves. Results: The percentage error found between the physicist’s manual calculation and RadShield’s semi-automated calculation of lead barrier thickness was 3.42% and 21.17% for the DLP and isodose curve methods, respectively. The medical physicist’s selection of calculation points for recommending lead thickness was roughly the same as those found by RadShield for the DLP method but differed greatly using the isodose method. Conclusion: RadShield improves accuracy in calculating air-kerma rate and barrier thickness over manual calculations using isodose curves. Isodose curves were less intuitive and more prone to error for the physicist than inverse square methods. RadShield can now perform shielding design calculations for general scattering bodies for which isodose curves are provided.« less

  8. Who wants to enroll in health care PhD programs? An analysis of a nationwide graduate destination survey.

    PubMed

    Pan, Ying-Ju; Lee, Lung-Sheng

    2012-06-01

    PhD training is important for national human resource development in the era of the "knowledge economy". However, it is not clear what factors are associated with the decision of a master's degree graduate to pursue a PhD degree in health care, including medicine, public health, and nursing. It is postulated that the intention to pursue a PhD degree in health care is associated with a graduate's attributes, academic publication, socioeconomic status, and extent of financial support. A cross-sectional investigation was conducted to analyze data from the 2007 nationwide graduate destination survey in Taiwan. Logistic regression with a forward stepwise model selection strategy was applied to identify those significant factors related to the intention of master's degree graduates to pursue a PhD degree in health care. The predictive validity of the selected model was evaluated using the receiver operating characteristics curve analysis. Of the 1668 master's degree graduates who responded to the survey, only 240 (14.4%) indicated a desire to pursue a PhD degree. Seven factors are identified to be independently associated with the intention to pursue a PhD degree in health care, including female gender [odds ratio (OR)=0.18, 95% confidence interval: 0.13-0.26], more than 2 years in graduate school (OR=0.46), working during graduate school (OR=0.47), submission of conference and journal articles (OR=1.61 and 1.48, respectively), tuition source, and parents' educational level. The predictive validity of the selected model was 0.77. These findings provide an overview of potential PhD students in the field of health care. Based on this assessment, effective strategies need to be developed to attract and retain qualified candidates, as well as other types of PhD students who are in demand in this field. Copyright © 2012. Published by Elsevier B.V.

  9. A method for determining the column curve from tests of columns with equal restraints against rotation on the ends

    NASA Technical Reports Server (NTRS)

    Lundquist, Eugene E; Rossman, Carl A; Houbolt, John C

    1943-01-01

    The results are presented of a theoretical study for the determination of the column curve from tests of column specimens having ends equally restrained against rotation. The theory of this problem is studied and a curve is shown relating the fixity coefficient c to the critical load, the length of the column, and the magnitude of the elastic restraint. A method of using this curve for the determination of the column curve for columns with pin ends from tests of columns with elastically restrained ends is presented. The results of the method as applied to a series of tests on thin-strip columns of stainless steel are also given.

  10. Developing a Robust Strategy for Implementing a Water Resources Master Plan in Lima, Peru

    NASA Astrophysics Data System (ADS)

    Kalra, N.; Groves, D.; Bonzanigo, L.; Molina-Perez, E.

    2015-12-01

    Lima, the capital of Peru, faces significant water stress. It is the fifth largest metropolitan area in Latin America, and the second largest desert city in the world. The city has developed a Master Plan of major investment projects to improve water reliability until 2040. Yet key questions remain. Is the Master Plan sufficient for ensuring reliability in the face of deeply uncertain future climate change and demand? How do uncertain budget and project feasibility conditions shape Lima's options? How should the investments in the plan be prioritized, and can some be delayed? Lima is not alone in facing these planning challenges. Governments invest billions of dollars annually in long-term projects. Yet deep uncertainties pose formidable challenges to making near-term decisions that make long-term sense. The World Bank has spearheaded a community of practice on methods for Decision Making Under Deep Uncertainty (DMU). This pilot project in Peru is the first in-depth application of DMU techniques to water supply planning in a developing country. It builds on prior analysis done in New York, California, and for the Colorado River, yet shows how these methods can be applied in regions which do not have as advanced data or tools available. The project combines three methods in particular -- Robust Decision Making, Decision Scaling, and Adaptive Pathways -- to help Lima implement its Master Plan in a way that is robust, no-regret, and adaptive. It was done in close partnership with SEDAPAL, the water utility company in Lima, and in coordination with other national WRM and meteorological agencies. This talk will: Present the planning challenges Lima and other cities face, including climate change Describe DMU methodologies and how they were applied in collaboration with SEDAPAL Summarize recommendations for achieving long-term water reliability in Lima Suggest how these methodologies can benefit other investment projects in developing countries.

  11. Synchronisation control for neutral-type multi-slave stochastic hybrid systems

    NASA Astrophysics Data System (ADS)

    Zhou, Jun; Pan, Feng; Cai, Tingting; Sun, Yuqing; Zhou, Wuneng; Liu, Huashan

    2017-10-01

    In this paper, an exponential synchronisation problem for neutral-type multi-slave hybrid systems with stochastic perturbation is discussed, where the adaptive synchronisation model involves a master system and multiple slave systems. By the use of generalised It?'s formula and M-matrix method, a sufficient condition is obtained to guarantee the stability of the error system, and the update law of the feedback controller is determined to deduce the synchronisation between the master system and the sum system of all slave systems. Finally, a numerical example is given to illustrate the effectiveness of the results obtained in this paper.

  12. End-pumped 300 W continuous-wave ytterbium-doped all-fiber laser with master oscillator multi-stage power amplifiers configuration.

    PubMed

    Yin, Shupeng; Yan, Ping; Gong, Mali

    2008-10-27

    An end-pumped ytterbium-doped all-fiber laser with 300 W output in continuous regime was reported, which was based on master oscillator multi-stage power amplifiers configuration. Monolithic fiber laser system consisted of an oscillator stage and two amplifier stages. Total optical-optical efficiency of monolithic fiber laser was approximately 65%, corresponding to 462 W of pump power coupled into laser system. We proposed a new method to connect power amplifier stage, which was crucial for the application of end-pumped combiner in high power MOPAs all-fiber laser.

  13. 75 FR 8039 - Announcement of the American Petroleum Institute's Standards Activities

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-02-23

    ... Provers, 3rd Ed. MPMS Ch. 4.9.3, Methods of Calibration for Displacement and Volumetric Tank Provers, Part 3--Determination of the Volume of Displacement Provers by the Master Meter Method of Calibration, 1st Ed. MPMS Ch. 4.9.4, Methods of Calibration for Displacement and Volumetric Tank Provers, Part 4...

  14. Didactic Aspects of the Academic Discipline "History and Methodology of Mathematics"

    ERIC Educational Resources Information Center

    Sun, Hai; Varankina, Vera I.; Sadovaya, Victoriya V.

    2017-01-01

    The purpose of this article is to develop the content and methods, as well as the analysis of the approbation of the program of the academic discipline "History and methodology of mathematics" for graduate students of the Master's program of mathematical program tracks. The leading method in the study of this problem was the method of…

  15. Synchronization sampling method based on delta-sigma analog-digital converter for underwater towed array system.

    PubMed

    Jiang, Jia-Jia; Duan, Fa-Jie; Li, Yan-Chao; Hua, Xiang-Ning

    2014-03-01

    Synchronization sampling is very important in underwater towed array system where every acquisition node (AN) samples analog signals by its own analog-digital converter (ADC). In this paper, a simple and effective synchronization sampling method is proposed to ensure synchronized operation among different ANs of the underwater towed array system. We first present a master-slave synchronization sampling model, and then design a high accuracy phase-locked loop to synchronize all delta-sigma ADCs to a reference clock. However, when the master-slave synchronization sampling model is used, both the time-delay (TD) of messages traveling along the wired transmission medium and the jitter of the clocks will bring out synchronization sampling error (SSE). Therefore, a simple method is proposed to estimate and compensate the TD of the messages transmission, and then another effective method is presented to overcome the SSE caused by the jitter of the clocks. An experimental system with three ANs is set up, and the related experimental results verify the validity of the synchronization sampling method proposed in this paper.

  16. Synchronization sampling method based on delta-sigma analog-digital converter for underwater towed array system

    NASA Astrophysics Data System (ADS)

    Jiang, Jia-Jia; Duan, Fa-Jie; Li, Yan-Chao; Hua, Xiang-Ning

    2014-03-01

    Synchronization sampling is very important in underwater towed array system where every acquisition node (AN) samples analog signals by its own analog-digital converter (ADC). In this paper, a simple and effective synchronization sampling method is proposed to ensure synchronized operation among different ANs of the underwater towed array system. We first present a master-slave synchronization sampling model, and then design a high accuracy phase-locked loop to synchronize all delta-sigma ADCs to a reference clock. However, when the master-slave synchronization sampling model is used, both the time-delay (TD) of messages traveling along the wired transmission medium and the jitter of the clocks will bring out synchronization sampling error (SSE). Therefore, a simple method is proposed to estimate and compensate the TD of the messages transmission, and then another effective method is presented to overcome the SSE caused by the jitter of the clocks. An experimental system with three ANs is set up, and the related experimental results verify the validity of the synchronization sampling method proposed in this paper.

  17. [Comparison among various software for LMS growth curve fitting methods].

    PubMed

    Han, Lin; Wu, Wenhong; Wei, Qiuxia

    2015-03-01

    To explore the methods to realize the growth curve fitting of coefficients of skewness-median-coefficient of variation (LMS) using different software, and to optimize growth curve statistical method for grass-root child and adolescent staffs. Regular physical examination data of head circumference for normal infants aging 3, 6, 9 and 12 months in Baotou City were analyzed. Statistical software such as SAS, R, STATA and SPSS were used to fit the LMS growth curve and the results were evaluated upon the user 's convenience, study circle, user interface, results display forms, software update and maintenance and so on. Growth curve fitting results showed the same calculation outcome and each of statistical software had its own advantages and disadvantages. With all the evaluation aspects in consideration, R software excelled others in LMS growth curve fitting. R software have the advantage over other software in grass roots child and adolescent staff.

  18. Accuracy of AFM force distance curves via direct solution of the Euler-Bernoulli equation

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Eppell, Steven J., E-mail: steven.eppell@case.edu; Liu, Yehe; Zypman, Fredy R.

    2016-03-15

    In an effort to improve the accuracy of force-separation curves obtained from atomic force microscope data, we compare force-separation curves computed using two methods to solve the Euler-Bernoulli equation. A recently introduced method using a direct sequential forward solution, Causal Time-Domain Analysis, is compared against a previously introduced Tikhonov Regularization method. Using the direct solution as a benchmark, it is found that the regularization technique is unable to reproduce accurate curve shapes. Using L-curve analysis and adjusting the regularization parameter, λ, to match either the depth or the full width at half maximum of the force curves, the two techniquesmore » are contrasted. Matched depths result in full width at half maxima that are off by an average of 27% and matched full width at half maxima produce depths that are off by an average of 109%.« less

  19. Improved Remote Sensing Retrieval of Land Surface Temperature in the Thermal Infrared (TIR) Using Visible/Short Wave Infrared (VSWIR) Imaging Spectrometer Estimated Water Vapor

    NASA Astrophysics Data System (ADS)

    Grigsby, S.; Hulley, G. C.; Roberts, D. A.; Scheele, C. J.; Ustin, S.; Alsina, M. M.

    2014-12-01

    Land surface temperature (LST) is an important parameter in many ecological studies, where processes such as evapotranspiration have impacts at temperature gradients less than 1 K. Current errors in standard MODIS and ASTER LST products are greater than 1 K, and for ASTER can be greater than 2 K in humid conditions due to incomplete atmospheric correction of atmospheric water vapor. Estimates of water vapor, either derived from visible-to-shortwave-infrared (VSWIR) remote sensing data or taken from weather simulation data such as NCEP, can be combined with coincident Thermal-Infrared (TIR) remote sensing data to yield improved accuracy in LST measurements. This study compares LST retrieval accuracies derived using the standard JPL MASTER Temperature Emissivity Separation (TES) algorithm, and the Water Vapor Scaling (WVS) atmospheric correction method proposed for the Hyperspectral Infrared Imager, or HyspIRI, mission with ground observations. The 2011 ER-2 Delano/Lost Hills flights acquired TIR data from the MODIS/ASTER Simulator (MASTER) and VSWIR data from Airborne Visible InfraRed Imaging Spectrometer (AVIRIS) instruments flown concurrently. The TES and WVS retrieval methods are run with and without high spatial resolution AVIRIS-derived water vapor maps to assess the improvement using VSWIR water vapor estimates. We find improvement using VSWIR derived water vapor maps in both cases, with the WVS method being most accurate overall. For closed canopy agricultural vegetation we observed canopy temperature retrieval RMSEs of 0.49 K and 0.70 K using the WVS method on MASTER data with and without AVIRIS derived water vapor, respectively.

  20. Solving the chemical master equation using sliding windows

    PubMed Central

    2010-01-01

    Background The chemical master equation (CME) is a system of ordinary differential equations that describes the evolution of a network of chemical reactions as a stochastic process. Its solution yields the probability density vector of the system at each point in time. Solving the CME numerically is in many cases computationally expensive or even infeasible as the number of reachable states can be very large or infinite. We introduce the sliding window method, which computes an approximate solution of the CME by performing a sequence of local analysis steps. In each step, only a manageable subset of states is considered, representing a "window" into the state space. In subsequent steps, the window follows the direction in which the probability mass moves, until the time period of interest has elapsed. We construct the window based on a deterministic approximation of the future behavior of the system by estimating upper and lower bounds on the populations of the chemical species. Results In order to show the effectiveness of our approach, we apply it to several examples previously described in the literature. The experimental results show that the proposed method speeds up the analysis considerably, compared to a global analysis, while still providing high accuracy. Conclusions The sliding window method is a novel approach to address the performance problems of numerical algorithms for the solution of the chemical master equation. The method efficiently approximates the probability distributions at the time points of interest for a variety of chemically reacting systems, including systems for which no upper bound on the population sizes of the chemical species is known a priori. PMID:20377904

  1. Pooling sheep faecal samples for the assessment of anthelmintic drug efficacy using McMaster and Mini-FLOTAC in gastrointestinal strongyle and Nematodirus infection.

    PubMed

    Kenyon, Fiona; Rinaldi, Laura; McBean, Dave; Pepe, Paola; Bosco, Antonio; Melville, Lynsey; Devin, Leigh; Mitchell, Gillian; Ianniello, Davide; Charlier, Johannes; Vercruysse, Jozef; Cringoli, Giuseppe; Levecke, Bruno

    2016-07-30

    In small ruminants, faecal egg counts (FECs) and reduction in FECs (FECR) are the most common methods for the assessment of intensity of gastrointestinal (GI) nematodes infections and anthelmintic drug efficacy, respectively. The main limitation of these methods is the time and cost to conduct FECs on a representative number of individual animals. A cost-saving alternative would be to examine pooled faecal samples, however little is known regarding whether pooling can give representative results. In the present study, we compared the FECR results obtained by both an individual and a pooled examination strategy across different pool sizes and analytical sensitivity of the FEC techniques. A survey was conducted on 5 sheep farms in Scotland, where anthelmintic resistance is known to be widespread. Lambs were treated with fenbendazole (4 groups), levamisole (3 groups), ivermectin (3 groups) or moxidectin (1 group). For each group, individual faecal samples were collected from 20 animals, at baseline (D0) and 14 days after (D14) anthelmintic administration. Faecal samples were analyzed as pools of 3-5, 6-10, and 14-20 individual samples. Both individual and pooled samples were screened for GI strongyle and Nematodirus eggs using two FEC techniques with three different levels of analytical sensitivity, including Mini-FLOTAC (analytical sensitivity of 10 eggs per gram of faeces (EPG)) and McMaster (analytical sensitivity of 15 or 50 EPG).For both Mini-FLOTAC and McMaster (analytical sensitivity of 15 EPG), there was a perfect agreement in classifying the efficacy of the anthelmintic as 'normal', 'doubtful' or 'reduced' regardless of pool size. When using the McMaster method (analytical sensitivity of 50 EPG) anthelmintic efficacy was often falsely classified as 'normal' or assessment was not possible due to zero FECs at D0, and this became more pronounced when the pool size increased. In conclusion, pooling ovine faecal samples holds promise as a cost-saving and efficient strategy for assessing GI nematode FECR. However, for the assessment FECR one will need to consider the baseline FEC, pool size and analytical sensitivity of the method. Copyright © 2016. Published by Elsevier B.V.

  2. Evaluation of qPCR curve analysis methods for reliable biomarker discovery: bias, resolution, precision, and implications.

    PubMed

    Ruijter, Jan M; Pfaffl, Michael W; Zhao, Sheng; Spiess, Andrej N; Boggy, Gregory; Blom, Jochen; Rutledge, Robert G; Sisti, Davide; Lievens, Antoon; De Preter, Katleen; Derveaux, Stefaan; Hellemans, Jan; Vandesompele, Jo

    2013-01-01

    RNA transcripts such as mRNA or microRNA are frequently used as biomarkers to determine disease state or response to therapy. Reverse transcription (RT) in combination with quantitative PCR (qPCR) has become the method of choice to quantify small amounts of such RNA molecules. In parallel with the democratization of RT-qPCR and its increasing use in biomedical research or biomarker discovery, we witnessed a growth in the number of gene expression data analysis methods. Most of these methods are based on the principle that the position of the amplification curve with respect to the cycle-axis is a measure for the initial target quantity: the later the curve, the lower the target quantity. However, most methods differ in the mathematical algorithms used to determine this position, as well as in the way the efficiency of the PCR reaction (the fold increase of product per cycle) is determined and applied in the calculations. Moreover, there is dispute about whether the PCR efficiency is constant or continuously decreasing. Together this has lead to the development of different methods to analyze amplification curves. In published comparisons of these methods, available algorithms were typically applied in a restricted or outdated way, which does not do them justice. Therefore, we aimed at development of a framework for robust and unbiased assessment of curve analysis performance whereby various publicly available curve analysis methods were thoroughly compared using a previously published large clinical data set (Vermeulen et al., 2009) [11]. The original developers of these methods applied their algorithms and are co-author on this study. We assessed the curve analysis methods' impact on transcriptional biomarker identification in terms of expression level, statistical significance, and patient-classification accuracy. The concentration series per gene, together with data sets from unpublished technical performance experiments, were analyzed in order to assess the algorithms' precision, bias, and resolution. While large differences exist between methods when considering the technical performance experiments, most methods perform relatively well on the biomarker data. The data and the analysis results per method are made available to serve as benchmark for further development and evaluation of qPCR curve analysis methods (http://qPCRDataMethods.hfrc.nl). Copyright © 2012 Elsevier Inc. All rights reserved.

  3. The computational complexity of elliptic curve integer sub-decomposition (ISD) method

    NASA Astrophysics Data System (ADS)

    Ajeena, Ruma Kareem K.; Kamarulhaili, Hailiza

    2014-07-01

    The idea of the GLV method of Gallant, Lambert and Vanstone (Crypto 2001) is considered a foundation stone to build a new procedure to compute the elliptic curve scalar multiplication. This procedure, that is integer sub-decomposition (ISD), will compute any multiple kP of elliptic curve point P which has a large prime order n with two low-degrees endomorphisms ψ1 and ψ2 of elliptic curve E over prime field Fp. The sub-decomposition of values k1 and k2, not bounded by ±C√n , gives us new integers k11, k12, k21 and k22 which are bounded by ±C√n and can be computed through solving the closest vector problem in lattice. The percentage of a successful computation for the scalar multiplication increases by ISD method, which improved the computational efficiency in comparison with the general method for computing scalar multiplication in elliptic curves over the prime fields. This paper will present the mechanism of ISD method and will shed light mainly on the computation complexity of the ISD approach that will be determined by computing the cost of operations. These operations include elliptic curve operations and finite field operations.

  4. A quick on-line state of health estimation method for Li-ion battery with incremental capacity curves processed by Gaussian filter

    NASA Astrophysics Data System (ADS)

    Li, Yi; Abdel-Monem, Mohamed; Gopalakrishnan, Rahul; Berecibar, Maitane; Nanini-Maury, Elise; Omar, Noshin; van den Bossche, Peter; Van Mierlo, Joeri

    2018-01-01

    This paper proposes an advanced state of health (SoH) estimation method for high energy NMC lithium-ion batteries based on the incremental capacity (IC) analysis. IC curves are used due to their ability of detect and quantify battery degradation mechanism. A simple and robust smoothing method is proposed based on Gaussian filter to reduce the noise on IC curves, the signatures associated with battery ageing can therefore be accurately identified. A linear regression relationship is found between the battery capacity with the positions of features of interest (FOIs) on IC curves. Results show that the developed SoH estimation function from one single battery cell is able to evaluate the SoH of other batteries cycled under different cycling depth with less than 2.5% maximum errors, which proves the robustness of the proposed method on SoH estimation. With this technique, partial charging voltage curves can be used for SoH estimation and the testing time can be therefore largely reduced. This method shows great potential to be applied in reality, as it only requires static charging curves and can be easily implemented in battery management system (BMS).

  5. Research in Education: Evidence-Based Inquiry, 7th Edition. MyEducationLab Series

    ERIC Educational Resources Information Center

    McMillan, James H.; Schumacher, Sally

    2010-01-01

    This substantially revised text provides a comprehensive, highly accessible, and student friendly introduction to the principles, concepts, and methods currently used in educational research. This text provides a balanced combination of quantitative and qualitative methods and enables students to master skills in reading, understanding,…

  6. Mastering Cognitive Development Theory in Computer Science Education

    ERIC Educational Resources Information Center

    Gluga, Richard; Kay, Judy; Lister, Raymond; Kleitman, Simon; Kleitman, Sabina

    2013-01-01

    To design an effective computer science curriculum, educators require a systematic method of classifying the difficulty level of learning activities and assessment tasks. This is important for curriculum design and implementation and for communication between educators. Different educators must be able to use the method consistently, so that…

  7. Creating Simulations for An "Introduction to Research Methods" Course

    ERIC Educational Resources Information Center

    Adamson, Bob

    2010-01-01

    This paper describes the production of a software program for Master of Education students studying the "Introduction to Research Methods" course at a tertiary institution in Hong Kong. The course was originally delivered in a lecture mode, which proved unsatisfactory in providing sufficient learning support for the students. The paper…

  8. Developing Sustainable Learning Communities through Blogging

    ERIC Educational Resources Information Center

    Custin, Richard; Barkacs, Linda

    2010-01-01

    Students have an uncanny ability to outpace faculty ability to master technology. Blogging, texting, flash video and other methods of electronic communication have supplanted more mundane methods of communication. In this paper, it is proposed that instituting a perpetual blog that encompasses a course taught by multiple faculty members will…

  9. Controlling Color in Oil Painting.

    ERIC Educational Resources Information Center

    Amorino, Joseph

    1990-01-01

    Explains how a veil control method allows secondary students to use oil paints in the classroom without difficulties of control, manageability, and clean up. Outlines how to prepare and apply oil glazes. Maintains that this method enhances students' studio skills and helps them appreciate the works of the great masters. (KM)

  10. Craniofacial Reconstruction Using Rational Cubic Ball Curves

    PubMed Central

    Majeed, Abdul; Mt Piah, Abd Rahni; Gobithaasan, R. U.; Yahya, Zainor Ridzuan

    2015-01-01

    This paper proposes the reconstruction of craniofacial fracture using rational cubic Ball curve. The idea of choosing Ball curve is based on its robustness of computing efficiency over Bezier curve. The main steps are conversion of Digital Imaging and Communications in Medicine (Dicom) images to binary images, boundary extraction and corner point detection, Ball curve fitting with genetic algorithm and final solution conversion to Dicom format. The last section illustrates a real case of craniofacial reconstruction using the proposed method which clearly indicates the applicability of this method. A Graphical User Interface (GUI) has also been developed for practical application. PMID:25880632

  11. Topographies and dynamics on multidimensional potential energy surfaces

    NASA Astrophysics Data System (ADS)

    Ball, Keith Douglas

    The stochastic master equation is a valuable tool for elucidating potential energy surface (PES) details that govern structural relaxation in clusters, bulk systems, and protein folding. This work develops a comprehensive framework for studying non-equilibrium relaxation dynamics using the master equation. Since our master equations depend upon accurate partition function models for use in Rice-Ramsperger-Kassel-Marcus (RRK(M) transition state theory, this work introduces several such models employing various harmonic and anharmonic approximations and compares their predicted equilibrium population distributions with those determined from molecular dynamics. This comparison is performed for the fully-delineated surfaces (KCl)5 and Ar9 to evaluate model performance for potential surfaces with long- and short-range interactions, respectively. For each system, several models perform better than a simple harmonic approximation. While no model gives acceptable results for all minima, and optimal modeling strategies differ for (KCl)5 and Ar9, a particular one-parameter model gives the best agreement with simulation for both systems. We then construct master equations from these models and compare their isothermal relaxation predictions for (KCl)5 and Ar9 with molecular dynamics simulations. This is the first comprehensive test of the kinetic performance of partition function models of its kind. Our results show that accurate modeling of transition-state partition functions is more important for (KCl)5 than for Ar9 in reproducing simulation results, due to a marked stiffening anharmonicity in the transition-state normal modes of (KCl)5. For both systems, several models yield qualitative agreement with simulation over a large temperature range. To examine the robustness of the master equation when applied to larger systems, for which full topographical descriptions would be either impossible or infeasible, we compute relaxation predictions for Ar11 using a master equation constructed from data representing the full PES, and compare these predictions to those of reduced master equations based on statistical samples of the full PES. We introduce a sampling method which generates random, Boltzmann-weighted, energetically 'downhill' sequences. The study reveals that, at moderate temperatures, the slowest relaxation timescale converges as the number of sequences in a sample grows to ~1000. Furthermore, the asymptotic timescale is comparable to the full-PES value.

  12. Integrated analysis on static/dynamic aeroelasticity of curved panels based on a modified local piston theory

    NASA Astrophysics Data System (ADS)

    Yang, Zhichun; Zhou, Jian; Gu, Yingsong

    2014-10-01

    A flow field modified local piston theory, which is applied to the integrated analysis on static/dynamic aeroelastic behaviors of curved panels, is proposed in this paper. The local flow field parameters used in the modification are obtained by CFD technique which has the advantage to simulate the steady flow field accurately. This flow field modified local piston theory for aerodynamic loading is applied to the analysis of static aeroelastic deformation and flutter stabilities of curved panels in hypersonic flow. In addition, comparisons are made between results obtained by using the present method and curvature modified method. It shows that when the curvature of the curved panel is relatively small, the static aeroelastic deformations and flutter stability boundaries obtained by these two methods have little difference, while for curved panels with larger curvatures, the static aeroelastic deformation obtained by the present method is larger and the flutter stability boundary is smaller compared with those obtained by the curvature modified method, and the discrepancy increases with the increasing of curvature of panels. Therefore, the existing curvature modified method is non-conservative compared to the proposed flow field modified method based on the consideration of hypersonic flight vehicle safety, and the proposed flow field modified local piston theory for curved panels enlarges the application range of piston theory.

  13. Estimating the SCS runoff curve number in forest catchments of Korea

    NASA Astrophysics Data System (ADS)

    Choi, Hyung Tae; Kim, Jaehoon; Lim, Hong-geun

    2016-04-01

    To estimate flood runoff discharge is a very important work in design for many hydraulic structures in streams, rivers and lakes such as dams, bridges, culverts, and so on. So, many researchers have tried to develop better methods for estimating flood runoff discharge. The SCS runoff curve number is an empirical parameter determined by empirical analysis of runoff from small catchments and hillslope plots monitored by the USDA. This method is an efficient method for determining the approximate amount of runoff from a rainfall even in a particular area, and is very widely used all around the world. However, there is a quite difference between the conditions of Korea and USA in topography, geology and land use. Therefore, examinations in adaptability of the SCS runoff curve number need to raise the accuracy of runoff prediction using SCS runoff curve number method. The purpose of this study is to find the SCS runoff curve number based on the analysis of observed data from several experimental forest catchments monitored by the National Institute of Forest Science (NIFOS), as a pilot study to modify SCS runoff curve number for forest lands in Korea. Rainfall and runoff records observed in Gwangneung coniferous and broad leaves forests, Sinwol, Hwasoon, Gongju and Gyeongsan catchments were selected to analyze the variability of flood runoff coefficients during the last 5 years. This study shows that runoff curve numbers of the experimental forest catchments range from 55 to 65. SCS Runoff Curve number method is a widely used method for estimating design discharge for small ungauged watersheds. Therefore, this study can be helpful technically to estimate the discharge for forest watersheds in Korea with more accuracy.

  14. Determination of the human spine curve based on laser triangulation.

    PubMed

    Poredoš, Primož; Čelan, Dušan; Možina, Janez; Jezeršek, Matija

    2015-02-05

    The main objective of the present method was to automatically obtain a spatial curve of the thoracic and lumbar spine based on a 3D shape measurement of a human torso with developed scoliosis. Manual determination of the spine curve, which was based on palpation of the thoracic and lumbar spinous processes, was found to be an appropriate way to validate the method. Therefore a new, noninvasive, optical 3D method for human torso evaluation in medical practice is introduced. Twenty-four patients with confirmed clinical diagnosis of scoliosis were scanned using a specially developed 3D laser profilometer. The measuring principle of the system is based on laser triangulation with one-laser-plane illumination. The measurement took approximately 10 seconds at 700 mm of the longitudinal translation along the back. The single point measurement accuracy was 0.1 mm. Computer analysis of the measured surface returned two 3D curves. The first curve was determined by manual marking (manual curve), and the second was determined by detecting surface curvature extremes (automatic curve). The manual and automatic curve comparison was given as the root mean square deviation (RMSD) for each patient. The intra-operator study involved assessing 20 successive measurements of the same person, and the inter-operator study involved assessing measurements from 8 operators. The results obtained for the 24 patients showed that the typical RMSD between the manual and automatic curve was 5.0 mm in the frontal plane and 1.0 mm in the sagittal plane, which is a good result compared with palpatory accuracy (9.8 mm). The intra-operator repeatability of the presented method in the frontal and sagittal planes was 0.45 mm and 0.06 mm, respectively. The inter-operator repeatability assessment shows that that the presented method is invariant to the operator of the computer program with the presented method. The main novelty of the presented paper is the development of a new, non-contact method that provides a quick, precise and non-invasive way to determine the spatial spine curve for patients with developed scoliosis and the validation of the presented method using the palpation of the spinous processes, where no harmful ionizing radiation is present.

  15. Clarifications regarding the use of model-fitting methods of kinetic analysis for determining the activation energy from a single non-isothermal curve.

    PubMed

    Sánchez-Jiménez, Pedro E; Pérez-Maqueda, Luis A; Perejón, Antonio; Criado, José M

    2013-02-05

    This paper provides some clarifications regarding the use of model-fitting methods of kinetic analysis for estimating the activation energy of a process, in response to some results recently published in Chemistry Central journal. The model fitting methods of Arrhenius and Savata are used to determine the activation energy of a single simulated curve. It is shown that most kinetic models correctly fit the data, each providing a different value for the activation energy. Therefore it is not really possible to determine the correct activation energy from a single non-isothermal curve. On the other hand, when a set of curves are recorded under different heating schedules are used, the correct kinetic parameters can be clearly discerned. Here, it is shown that the activation energy and the kinetic model cannot be unambiguously determined from a single experimental curve recorded under non isothermal conditions. Thus, the use of a set of curves recorded under different heating schedules is mandatory if model-fitting methods are employed.

  16. Fitting the curve in Excel®: Systematic curve fitting of laboratory and remotely sensed planetary spectra

    NASA Astrophysics Data System (ADS)

    McCraig, Michael A.; Osinski, Gordon R.; Cloutis, Edward A.; Flemming, Roberta L.; Izawa, Matthew R. M.; Reddy, Vishnu; Fieber-Beyer, Sherry K.; Pompilio, Loredana; van der Meer, Freek; Berger, Jeffrey A.; Bramble, Michael S.; Applin, Daniel M.

    2017-03-01

    Spectroscopy in planetary science often provides the only information regarding the compositional and mineralogical make up of planetary surfaces. The methods employed when curve fitting and modelling spectra can be confusing and difficult to visualize and comprehend. Researchers who are new to working with spectra may find inadequate help or documentation in the scientific literature or in the software packages available for curve fitting. This problem also extends to the parameterization of spectra and the dissemination of derived metrics. Often, when derived metrics are reported, such as band centres, the discussion of exactly how the metrics were derived, or if there was any systematic curve fitting performed, is not included. Herein we provide both recommendations and methods for curve fitting and explanations of the terms and methods used. Techniques to curve fit spectral data of various types are demonstrated using simple-to-understand mathematics and equations written to be used in Microsoft Excel® software, free of macros, in a cut-and-paste fashion that allows one to curve fit spectra in a reasonably user-friendly manner. The procedures use empirical curve fitting, include visualizations, and ameliorates many of the unknowns one may encounter when using black-box commercial software. The provided framework is a comprehensive record of the curve fitting parameters used, the derived metrics, and is intended to be an example of a format for dissemination when curve fitting data.

  17. Using the weighted area under the net benefit curve for decision curve analysis.

    PubMed

    Talluri, Rajesh; Shete, Sanjay

    2016-07-18

    Risk prediction models have been proposed for various diseases and are being improved as new predictors are identified. A major challenge is to determine whether the newly discovered predictors improve risk prediction. Decision curve analysis has been proposed as an alternative to the area under the curve and net reclassification index to evaluate the performance of prediction models in clinical scenarios. The decision curve computed using the net benefit can evaluate the predictive performance of risk models at a given or range of threshold probabilities. However, when the decision curves for 2 competing models cross in the range of interest, it is difficult to identify the best model as there is no readily available summary measure for evaluating the predictive performance. The key deterrent for using simple measures such as the area under the net benefit curve is the assumption that the threshold probabilities are uniformly distributed among patients. We propose a novel measure for performing decision curve analysis. The approach estimates the distribution of threshold probabilities without the need of additional data. Using the estimated distribution of threshold probabilities, the weighted area under the net benefit curve serves as the summary measure to compare risk prediction models in a range of interest. We compared 3 different approaches, the standard method, the area under the net benefit curve, and the weighted area under the net benefit curve. Type 1 error and power comparisons demonstrate that the weighted area under the net benefit curve has higher power compared to the other methods. Several simulation studies are presented to demonstrate the improvement in model comparison using the weighted area under the net benefit curve compared to the standard method. The proposed measure improves decision curve analysis by using the weighted area under the curve and thereby improves the power of the decision curve analysis to compare risk prediction models in a clinical scenario.

  18. 48 CFR 217.7103-6 - Modification of master agreements.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... 48 Federal Acquisition Regulations System 3 2013-10-01 2013-10-01 false Modification of master... Master Agreement for Repair and Alteration of Vessels 217.7103-6 Modification of master agreements. (a) Review each master agreement at least annually before the anniversary of its effective date and revise it...

  19. 46 CFR 189.35-13 - Master's responsibility.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... 46 Shipping 7 2012-10-01 2012-10-01 false Master's responsibility. 189.35-13 Section 189.35-13... AND CERTIFICATION Weight Handling Gear § 189.35-13 Master's responsibility. (a) The master of the... permitted to operate the weight handling gear. The master shall designate the operators. (5) A minimum...

  20. 46 CFR Sec. 3 - Master's requirements.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 46 Shipping 8 2010-10-01 2010-10-01 false Master's requirements. Sec. 3 Section 3 Shipping... Master's requirements. The Master shall: (a) Receive and receipt for the quantities of slop chest items... therefor, at the unit price, specified by the Slop Chest Statement furnished the Master by the General...

Top